WorldWideScience

Sample records for surface-marker imaging system

  1. Transference of surface markers in X-ray, CT- and MR-imaging

    International Nuclear Information System (INIS)

    Grevelhoerster, T.; Poetter, R.; Prott, F.J.; Dittrich, M.

    1995-01-01

    By using pharmacological capsules and plastic tubes filled with oily contrast medium contraining iodine (Lipiodol; Byk Gulden), marking aids were developed which can be seen in similar definite limits within the framework of MRI-, CT- and conventional X-ray-Imaging. A method to view these new, artificial markers in combination with individual, anatomical landmarks is introduced. The marking aid/surface marker, fixed on anatomical reference structures on the skin, does not result in an additional burden for the patient. The new, artificial markers are also useful for making other structures recognizable, such as anatomical relation lines, center of the portal and edges in planning imaging for radiotherapy treatments and are used as leading and reference structures to compare localisation and extent of lesions in X-ray-, CT- and MRI. Marking aids/surface markers do not have to be changed in different imaging methods. (orig./MG) [de

  2. Surface imaging, portal imaging, and skin marker set-up vs. CBCT for radiotherapy of the thorax and pelvis

    International Nuclear Information System (INIS)

    Pallotta, Stefania; Bucciolini, Marta; Vanzi, Eleonora; Marrazzo, Livia; Simontacchi, Gabriele; Paiar, Fabiola; Ceroti, Marco; Livi, Lorenzo

    2015-01-01

    The aim of this study was to compare surface imaging, portal imaging, and skin marker set-up in radiotherapy of thoracic and pelvic regions, using cone beam computed tomography (CBCT) data as the gold standard. Twenty patients were included in this study. CBCT, surface acquisition (SA), and two orthogonal portal images (PI) were acquired during the first four treatment sessions. Patient set-up corrections, obtained by registering the planning CT with CBCT, were used as the gold standard. Registration results of the PI and SA were evaluated and compared with those obtained with CBCT. The advantage derived from using SA or PI verification systems over a skin marker set-up was also quantified. A statistically significant difference between PI and SA (in favour of PI) was observed in seven patients undergoing treatment of the pelvic region and in two patients undergoing treatment of the thoracic region. The use of SA or PI, compared with a skin marker set-up, improved patient positioning in 50% and 57 % of the thoracic fractions, respectively. For pelvic fractions, the use of PI was beneficial in 73 % of the cases, while the use of SA was beneficial in only 45 %. Patient positioning worsened with SA, particularly along longitudinal and vertical directions. PI yielded more accurate registration results than SA for both pelvic and thoracic fractions. Compared with the skin marker set-up, PI performances were superior to SA for pelvic fractions while comparable results were obtained for thoracic fractions. (orig.) [de

  3. Imaging of 1.0-mm-diameter radiopaque markers with megavoltage X-rays: an improved online imaging system

    International Nuclear Information System (INIS)

    Pang, G.; Beachey, D.J.; O'Brien, P.F.; Rowlands, J.A.

    2002-01-01

    Purpose: To improve an online portal imaging system such that implanted cylindrical gold markers of small diameter (no more than 1.0 mm) can be visualized. These small markers would make the implantation procedure much less traumatic for the patient than the large markers (1.6 mm in diameter), which are usually used today to monitor prostate interfraction motion during radiation therapy. Methods and Materials: Several changes have been made to a mirror-video based online imaging system to improve image quality. First, the conventional camera tube was replaced by an avalanche-multiplication-based video tube. This new camera tube has very high gain at the target such that the camera noise, which is one of the main causes of image degradation of online portal imaging systems, was overcome and effectively eliminated. Second, the conventional linear-accelerator (linac) target was replaced with a low atomic number (low-Z) target such that more diagnostic X-rays are present in the megavoltage X-ray beam. Third, the copper plate buildup layer for the phosphor screen was replaced by a thin plastic layer for detection of the diagnostic X-ray components in the beam generated by the low-Z target. Results: Radiopaque fiducial gold markers of different sizes, i.e., 1.0 mm (diameter) x 5 mm (length) and 0.8 mm (diameter) x 3 mm (length), embedded in an Alderson Rando phantom, can be clearly seen on the images acquired with our improved system. These markers could not be seen on images obtained with any commercial system available in our clinic. Conclusion: This work demonstrates the visibility of small-diameter radiopaque markers with an improved online portal imaging system. These markers can be easily implanted into the prostate and used to monitor the interfraction motion of the prostate

  4. Rapid and sensitive phenotypic marker detection on breast cancer cells using surface-enhanced Raman scattering (SERS) imaging.

    Science.gov (United States)

    Lee, Sangyeop; Chon, Hyangah; Lee, Jiyoung; Ko, Juhui; Chung, Bong Hyun; Lim, Dong Woo; Choo, Jaebum

    2014-01-15

    We report a surface-enhanced Raman scattering (SERS)-based cellular imaging technique to detect and quantify breast cancer phenotypic markers expressed on cell surfaces. This technique involves the synthesis of SERS nano tags consisting of silica-encapsulated hollow gold nanospheres (SEHGNs) conjugated with specific antibodies. Hollow gold nanospheres (HGNs) enhance SERS signal intensity of individual particles by localizing surface electromagnetic fields through pinholes in the hollow particle structures. This capacity to enhance imaging at the level of single molecules permits the use of HGNs to detect specific biological markers expressed in living cancer cells. In addition, silica encapsulation greatly enhances the stability of nanoparticles. Here we applied a SERS-based imaging technique using SEHGNs in the multiplex imaging of three breast cancer cell phenotypes. Expression of epidermal growth factor (EGF), ErbB2, and insulin-like growth factor-1 (IGF-1) receptors were assessed in the MDA-MB-468, KPL4 and SK-BR-3 human breast cancer cell lines. SERS imaging technology described here can be used to test the phenotype of a cancer cell and quantify proteins expressed on the cell surface simultaneously. Based on results, this technique may enable an earlier diagnosis of breast cancer than is currently possible and offer guidance in treatment. © 2013 Elsevier B.V. All rights reserved.

  5. Surface imaging, portal imaging, and skin marker set-up vs. CBCT for radiotherapy of the thorax and pelvis

    Energy Technology Data Exchange (ETDEWEB)

    Pallotta, Stefania; Bucciolini, Marta [Universita degli Studi di Firenze, Dipartimento di Scienze Biomediche Sperimentali e Cliniche, Florence (Italy); AOU Careggi, Sezione di Fisica Medica, Florence (Italy); Vanzi, Eleonora; Marrazzo, Livia [AOU Careggi, Sezione di Fisica Medica, Florence (Italy); Simontacchi, Gabriele; Paiar, Fabiola [AOU Careggi, Sezione di Radioterapia, Florence (Italy); Ceroti, Marco [ISPO, U.O. Epidemiologia Molecolare e Nutrizionale, Florence (Italy); Livi, Lorenzo [Universita degli Studi di Firenze, Dipartimento di Scienze Biomediche Sperimentali e Cliniche, Florence (Italy); AOU Careggi, Sezione di Radioterapia, Florence (Italy)

    2015-09-15

    The aim of this study was to compare surface imaging, portal imaging, and skin marker set-up in radiotherapy of thoracic and pelvic regions, using cone beam computed tomography (CBCT) data as the gold standard. Twenty patients were included in this study. CBCT, surface acquisition (SA), and two orthogonal portal images (PI) were acquired during the first four treatment sessions. Patient set-up corrections, obtained by registering the planning CT with CBCT, were used as the gold standard. Registration results of the PI and SA were evaluated and compared with those obtained with CBCT. The advantage derived from using SA or PI verification systems over a skin marker set-up was also quantified. A statistically significant difference between PI and SA (in favour of PI) was observed in seven patients undergoing treatment of the pelvic region and in two patients undergoing treatment of the thoracic region. The use of SA or PI, compared with a skin marker set-up, improved patient positioning in 50% and 57 % of the thoracic fractions, respectively. For pelvic fractions, the use of PI was beneficial in 73 % of the cases, while the use of SA was beneficial in only 45 %. Patient positioning worsened with SA, particularly along longitudinal and vertical directions. PI yielded more accurate registration results than SA for both pelvic and thoracic fractions. Compared with the skin marker set-up, PI performances were superior to SA for pelvic fractions while comparable results were obtained for thoracic fractions. (orig.) [German] Ziel dieser Studie ist der Vergleich der Patientenpositionierung mittels der 3-D/4-D-Erfassung der Patientenoberflaeche durch ein Abtastsystem, kV/MV-Verifikationsaufnahmen mit Hochenergiebildsystemen und Markierungen auf der Haut bei Bestrahlungen im Thorax- bzw. Beckenbereich. Als Goldstandard zum Vergleich dienten CBCT(''cone beam computed tomography'')-Aufnahmen. Die Studie basiert auf Untersuchungen an 20 Patienten. Es wurden

  6. Marker Detection in Aerial Images

    KAUST Repository

    Alharbi, Yazeed

    2017-04-09

    The problem that the thesis is trying to solve is the detection of small markers in high-resolution aerial images. Given a high-resolution image, the goal is to return the pixel coordinates corresponding to the center of the marker in the image. The marker has the shape of two triangles sharing a vertex in the middle, and it occupies no more than 0.01% of the image size. An improvement on the Histogram of Oriented Gradients (HOG) is proposed, eliminating the majority of baseline HOG false positives for marker detection. The improvement is guided by the observation that standard HOG description struggles to separate markers from negatives patches containing an X shape. The proposed method alters intensities with the aim of altering gradients. The intensity-dependent gradient alteration leads to more separation between filled and unfilled shapes. The improvement is used in a two-stage algorithm to achieve high recall and high precision in detection of markers in aerial images. In the first stage, two classifiers are used: one to quickly eliminate most of the uninteresting parts of the image, and one to carefully select the marker among the remaining interesting regions. Interesting regions are selected by scanning the image with a fast classifier trained on the HOG features of markers in all rotations and scales. The next classifier is more precise and uses our method to eliminate the majority of the false positives of standard HOG. In the second stage, detected markers are tracked forward and backward in time. Tracking is needed to detect extremely blurred or distorted markers that are missed by the previous stage. The algorithm achieves 94% recall with minimal user guidance. An average of 30 guesses are given per image; the user verifies for each whether it is a marker or not. The brute force approach would return 100,000 guesses per image.

  7. Immunogold labels: cell-surface markers in atomic force microscopy

    NARCIS (Netherlands)

    Putman, Constant A.J.; Putman, C.A.J.; de Grooth, B.G.; Hansma, Paul K.; van Hulst, N.F.; Greve, Jan

    1993-01-01

    The feasibility of using immunogold labels as cell-surface markers in atomic force microscopy is shown in this paper. The atomic force microscope (AFM) was used to image the surface of immunogold-labeled human lymphocytes. The lymphocytes were isolated from whole blood and labeled by an indirect

  8. Using surface markers for MRI guided breast conserving surgery: a feasibility survey

    Science.gov (United States)

    Ebrahimi, Mehran; Siegler, Peter; Modhafar, Amen; Holloway, Claire M. B.; Plewes, Donald B.; Martel, Anne L.

    2014-04-01

    Breast MRI is frequently performed prior to breast conserving surgery in order to assess the location and extent of the lesion. Ideally, the surgeon should also be able to use the image information during surgery to guide the excision and this requires that the MR image is co-registered to conform to the patient’s position on the operating table. Recent progress in MR imaging techniques has made it possible to obtain high quality images of the patient in the supine position which significantly reduces the complexity of the registration task. Surface markers placed on the breast during imaging can be located during surgery using an external tracking device and this information can be used to co-register the images to the patient. There remains the problem that in most clinical MR scanners the arm of the patient has to be placed parallel to the body whereas the arm is placed perpendicular to the patient during surgery. The aim of this study is to determine the accuracy of co-registration based on a surface marker approach and, in particular, to determine what effect the difference in a patient’s arm position makes on the accuracy of tumour localization. Obtaining a second MRI of the patient where the patient’s arm is perpendicular to body axes (operating room position) is not possible. Instead we obtain a secondary MRI scan where the patient’s arm is above the patient’s head to validate the registration. Five patients with enhancing lesions ranging from 1.5 to 80 cm3 in size were imaged using contrast enhanced MRI with their arms in two positions. A thin-plate spline registration scheme was used to match these two configurations. The registration algorithm uses the surface markers only and does not employ the image intensities. Tumour outlines were segmented and centre of mass (COM) displacement and Dice measures of lesion overlap were calculated. The relationship between the number of markers used and the COM-displacement was also studied. The lesion COM

  9. Using surface markers for MRI guided breast conserving surgery: a feasibility survey

    International Nuclear Information System (INIS)

    Ebrahimi, Mehran; Siegler, Peter; Modhafar, Amen; Martel, Anne L; Holloway, Claire M B; Plewes, Donald B

    2014-01-01

    Breast MRI is frequently performed prior to breast conserving surgery in order to assess the location and extent of the lesion. Ideally, the surgeon should also be able to use the image information during surgery to guide the excision and this requires that the MR image is co-registered to conform to the patient’s position on the operating table. Recent progress in MR imaging techniques has made it possible to obtain high quality images of the patient in the supine position which significantly reduces the complexity of the registration task. Surface markers placed on the breast during imaging can be located during surgery using an external tracking device and this information can be used to co-register the images to the patient. There remains the problem that in most clinical MR scanners the arm of the patient has to be placed parallel to the body whereas the arm is placed perpendicular to the patient during surgery. The aim of this study is to determine the accuracy of co-registration based on a surface marker approach and, in particular, to determine what effect the difference in a patient’s arm position makes on the accuracy of tumour localization. Obtaining a second MRI of the patient where the patient’s arm is perpendicular to body axes (operating room position) is not possible. Instead we obtain a secondary MRI scan where the patient’s arm is above the patient’s head to validate the registration. Five patients with enhancing lesions ranging from 1.5 to 80 cm 3 in size were imaged using contrast enhanced MRI with their arms in two positions. A thin-plate spline registration scheme was used to match these two configurations. The registration algorithm uses the surface markers only and does not employ the image intensities. Tumour outlines were segmented and centre of mass (COM) displacement and Dice measures of lesion overlap were calculated. The relationship between the number of markers used and the COM-displacement was also studied. The lesion

  10. Elevated tumour marker: an indication for imaging?

    LENUS (Irish Health Repository)

    McMahon, Colm J

    2012-02-01

    INTRODUCTION: The purpose of this study was to evaluate the utility of imaging examinations in patients with elevated tumour markers when (a) the tumour marker is not validated for as a primary diagnostic test; (b) the patient had no personal history of cancer and (c) the patient had no other imaging indication. MATERIALS AND METHODS: Patients without known cancer who had abnormal carcinoembryonic antigen, CA19-9, CA125 and\\/or CA15-3 serology over a one-year period were included. A retrospective medical record review was performed to assess the number of these cases who underwent imaging because of \\'elevated tumour marker\\' in the absence of a clinical indication for imaging. The number and result of these imaging studies were evaluated. RESULTS: Eight hundred and nineteen patients were included. Of those, 25 patients (mean age: 67.8 [range 41-91] y), were imaged to evaluate: \\'elevated tumour marker\\'. They underwent 29 imaging studies (mean [+\\/-standard deviation (SD)] per patient = 1.2 [+\\/-0.4]), and had 42 elevated tumour marker serology tests (mean [+\\/-SD] per patient = 1.7 [+\\/-0.7]). Four patients had >1 imaging test. No patient had an imaging study which diagnosed a malignancy or explained the elevated tumour marker. CONCLUSION: The non-judicious use of tumour markers can prompt further unnecessary investigations including imaging. In this study, there was no positive diagnostic yield for imaging performed for investigation of \\'elevated tumour marker\\'. \\'Elevated tumour marker\\

  11. Setup errors and effectiveness of Optical Laser 3D Surface imaging system (Sentinel) in postoperative radiotherapy of breast cancer.

    Science.gov (United States)

    Wei, Xiaobo; Liu, Mengjiao; Ding, Yun; Li, Qilin; Cheng, Changhai; Zong, Xian; Yin, Wenming; Chen, Jie; Gu, Wendong

    2018-05-08

    Breast-conserving surgery (BCS) plus postoperative radiotherapy has become the standard treatment for early-stage breast cancer. The aim of this study was to compare the setup accuracy of optical surface imaging by the Sentinel system with cone-beam computerized tomography (CBCT) imaging currently used in our clinic for patients received BCS. Two optical surface scans were acquired before and immediately after couch movement correction. The correlation between the setup errors as determined by the initial optical surface scan and CBCT was analyzed. The deviation of the second optical surface scan from the reference planning CT was considered an estimate for the residual errors for the new method for patient setup correction. The consequences in terms for necessary planning target volume (PTV) margins for treatment sessions without setup correction applied. We analyzed 145 scans in 27 patients treated for early stage breast cancer. The setup errors of skin marker based patient alignment by optical surface scan and CBCT were correlated, and the residual setup errors as determined by the optical surface scan after couch movement correction were reduced. Optical surface imaging provides a convenient method for improving the setup accuracy for breast cancer patient without unnecessary imaging dose.

  12. Technical validation of the Di3D stereophotogrammetry surface imaging system

    DEFF Research Database (Denmark)

    Winder, R.J.; Darvann, Tron Andre; McKnight, W.

    2008-01-01

    The purpose of this work was to assess the technical performance of a three-dimensional surface imaging system for geometric accuracy and maximum field of view. The system was designed for stereophotogrammetry capture of digital images from three-dimensional surfaces of the head, face, and neck...

  13. SU-E-J-42: Evaluation of Fiducial Markers for Ultrasound and X-Ray Images Used for Motion Tracking in Pancreas SBRT

    International Nuclear Information System (INIS)

    Ng, SK; Armour, E; Su, L; Zhang, Y; Wong, J; Ding, K; Iordachita, I; Sen, H Tutkun; Kazanzides, P; Bell, M Lediju

    2015-01-01

    Purpose Ultrasound tracking of target motion relies on visibility of vascular and/or anatomical landmark. However this is challenging when the target is located far from vascular structures or in organs that lack ultrasound landmark structure, such as in the case of pancreas cancer. The purpose of this study is to evaluate visibility, artifacts and distortions of fusion coils and solid gold markers in ultrasound, CT, CBCT and kV images to identify markers suitable for real-time ultrasound tracking of tumor motion in SBRT pancreas treatment. Methods Two fusion coils (1mm × 5mm and 1mm × 10 mm) and a solid gold marker (0.8mm × 10mm) were embedded in a tissue–like ultrasound phantom. The phantom (5cm × 12cm × 20cm) was prepared using water, gelatin and psyllium-hydrophilic-mucilloid fiber. Psylliumhydrophilic mucilloid acts as scattering medium to produce echo texture that simulates sonographic appearance of human tissue in ultrasound images while maintaining electron density close to that of water in CT images. Ultrasound images were acquired using 3D-ultrasound system with markers embedded at 5, 10 and 15mm depth from phantom surface. CT images were acquired using Philips Big Bore CT while CBCT and kV images were acquired with XVI-system (Elexta). Visual analysis was performed to compare visibility of the markers and visibility score (1 to 3) were assigned. Results All markers embedded at various depths are clearly visible (score of 3) in ultrasound images. Good visibility of all markers is observed in CT, CBCT and kV images. The degree of artifact produced by the markers in CT and CBCT images are indistinguishable. No distortion is observed in images from any modalities. Conclusion All markers are visible in images across all modalities in this homogenous tissue-like phantom. Human subject data is necessary to confirm the marker type suitable for real-time ultrasound tracking of tumor motion in SBRT pancreas treatment

  14. SU-E-J-42: Evaluation of Fiducial Markers for Ultrasound and X-Ray Images Used for Motion Tracking in Pancreas SBRT

    Energy Technology Data Exchange (ETDEWEB)

    Ng, SK; Armour, E; Su, L; Zhang, Y; Wong, J; Ding, K [Department of Radiation Oncology, Johns Hopkins University, Baltimore, MD (United States); Iordachita, I [Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD (United States); Sen, H Tutkun; Kazanzides, P; Bell, M Lediju [Department of Computer Science, Johns Hopkins University, Baltimore, MD (United States)

    2015-06-15

    Purpose Ultrasound tracking of target motion relies on visibility of vascular and/or anatomical landmark. However this is challenging when the target is located far from vascular structures or in organs that lack ultrasound landmark structure, such as in the case of pancreas cancer. The purpose of this study is to evaluate visibility, artifacts and distortions of fusion coils and solid gold markers in ultrasound, CT, CBCT and kV images to identify markers suitable for real-time ultrasound tracking of tumor motion in SBRT pancreas treatment. Methods Two fusion coils (1mm × 5mm and 1mm × 10 mm) and a solid gold marker (0.8mm × 10mm) were embedded in a tissue–like ultrasound phantom. The phantom (5cm × 12cm × 20cm) was prepared using water, gelatin and psyllium-hydrophilic-mucilloid fiber. Psylliumhydrophilic mucilloid acts as scattering medium to produce echo texture that simulates sonographic appearance of human tissue in ultrasound images while maintaining electron density close to that of water in CT images. Ultrasound images were acquired using 3D-ultrasound system with markers embedded at 5, 10 and 15mm depth from phantom surface. CT images were acquired using Philips Big Bore CT while CBCT and kV images were acquired with XVI-system (Elexta). Visual analysis was performed to compare visibility of the markers and visibility score (1 to 3) were assigned. Results All markers embedded at various depths are clearly visible (score of 3) in ultrasound images. Good visibility of all markers is observed in CT, CBCT and kV images. The degree of artifact produced by the markers in CT and CBCT images are indistinguishable. No distortion is observed in images from any modalities. Conclusion All markers are visible in images across all modalities in this homogenous tissue-like phantom. Human subject data is necessary to confirm the marker type suitable for real-time ultrasound tracking of tumor motion in SBRT pancreas treatment.

  15. The Application of Three-Dimensional Surface Imaging System in Plastic and Reconstructive Surgery.

    Science.gov (United States)

    Li, Yanqi; Yang, Xin; Li, Dong

    2016-02-01

    Three-dimensional (3D) surface imaging system has gained popularity worldwide in clinical application. Unlike computed tomography and magnetic resonance imaging, it has the ability to capture 3D images with both shape and texture information. This feature has made it quite useful for plastic surgeons. This review article is mainly focusing on demonstrating the current status and analyzing the future of the application of 3D surface imaging systems in plastic and reconstructive surgery.Currently, 3D surface imaging system is mainly used in plastic and reconstructive surgery to help improve the reliability of surgical planning and assessing surgical outcome objectively. There have already been reports of its using on plastic and reconstructive surgery from head to toe. Studies on facial aging process, online applications development, and so on, have also been done through the use of 3D surface imaging system.Because different types of 3D surface imaging devices have their own advantages and disadvantages, a basic knowledge of their features is required and careful thought should be taken to choose the one that best fits a surgeon's demand.In the future, by integrating with other imaging tools and the 3D printing technology, 3D surface imaging system will play an important role in individualized surgical planning, implants production, meticulous surgical simulation, operative techniques training, and patient education.

  16. Risk stratification in cardiovascular disease primary prevention - scoring systems, novel markers, and imaging techniques.

    LENUS (Irish Health Repository)

    Zannad, Faiez

    2012-04-01

    The aim of this paper is to review and discuss current methods of risk stratification for cardiovascular disease (CVD) prevention, emerging biomarkers, and imaging techniques, and their relative merits and limitations. This report is based on discussions that took place among experts in the area during a special CardioVascular Clinical Trialists workshop organized by the European Society of Cardiology Working Group on Cardiovascular Pharmacology and Drug Therapy in September 2009. Classical risk factors such as blood pressure and low-density lipoprotein cholesterol levels remain the cornerstone of risk estimation in primary prevention but their use as a guide to management is limited by several factors: (i) thresholds for drug treatment vary with the available evidence for cost-effectiveness and benefit-to-risk ratios; (ii) assessment may be imprecise; (iii) residual risk may remain, even with effective control of dyslipidemia and hypertension. Novel measures include C-reactive protein, lipoprotein-associated phospholipase A(2) , genetic markers, and markers of subclinical organ damage, for which there are varying levels of evidence. High-resolution ultrasound and magnetic resonance imaging to assess carotid atherosclerotic lesions have potential but require further validation, standardization, and proof of clinical usefulness in the general population. In conclusion, classical risk scoring systems are available and inexpensive but have a number of limitations. Novel risk markers and imaging techniques may have a place in drug development and clinical trial design. However, their additional value above and beyond classical risk factors has yet to be determined for risk-guided therapy in CVD prevention.

  17. Geometry planning and image registration in magnetic particle imaging using bimodal fiducial markers

    International Nuclear Information System (INIS)

    Werner, F.; Hofmann, M.; Them, K.; Knopp, T.; Jung, C.; Salamon, J.; Kaul, M. G.; Mummert, T.; Adam, G.; Ittrich, H.; Werner, R.; Säring, D.; Weber, O. M.

    2016-01-01

    Purpose: Magnetic particle imaging (MPI) is a quantitative imaging modality that allows the distribution of superparamagnetic nanoparticles to be visualized. Compared to other imaging techniques like x-ray radiography, computed tomography (CT), and magnetic resonance imaging (MRI), MPI only provides a signal from the administered tracer, but no additional morphological information, which complicates geometry planning and the interpretation of MP images. The purpose of the authors’ study was to develop bimodal fiducial markers that can be visualized by MPI and MRI in order to create MP–MR fusion images. Methods: A certain arrangement of three bimodal fiducial markers was developed and used in a combined MRI/MPI phantom and also during in vivo experiments in order to investigate its suitability for geometry planning and image fusion. An algorithm for automated marker extraction in both MR and MP images and rigid registration was established. Results: The developed bimodal fiducial markers can be visualized by MRI and MPI and allow for geometry planning as well as automated registration and fusion of MR–MP images. Conclusions: To date, exact positioning of the object to be imaged within the field of view (FOV) and the assignment of reconstructed MPI signals to corresponding morphological regions has been difficult. The developed bimodal fiducial markers and the automated image registration algorithm help to overcome these difficulties.

  18. Geometry planning and image registration in magnetic particle imaging using bimodal fiducial markers

    Energy Technology Data Exchange (ETDEWEB)

    Werner, F., E-mail: f.werner@uke.de; Hofmann, M.; Them, K.; Knopp, T. [Section for Biomedical Imaging, University Medical Center Hamburg-Eppendorf, Hamburg 20246, Germany and Institute for Biomedical Imaging, Hamburg University of Technology, Hamburg 21073 (Germany); Jung, C.; Salamon, J.; Kaul, M. G.; Mummert, T.; Adam, G.; Ittrich, H. [Department of Diagnostic and Interventional Radiology, University Medical Center Hamburg-Eppendorf, Hamburg 20246 (Germany); Werner, R.; Säring, D. [Institute for Computational Neuroscience, University Medical Center Hamburg-Eppendorf, Hamburg 20246 (Germany); Weber, O. M. [Philips Medical Systems DMC GmbH, Hamburg 22335 (Germany)

    2016-06-15

    Purpose: Magnetic particle imaging (MPI) is a quantitative imaging modality that allows the distribution of superparamagnetic nanoparticles to be visualized. Compared to other imaging techniques like x-ray radiography, computed tomography (CT), and magnetic resonance imaging (MRI), MPI only provides a signal from the administered tracer, but no additional morphological information, which complicates geometry planning and the interpretation of MP images. The purpose of the authors’ study was to develop bimodal fiducial markers that can be visualized by MPI and MRI in order to create MP–MR fusion images. Methods: A certain arrangement of three bimodal fiducial markers was developed and used in a combined MRI/MPI phantom and also during in vivo experiments in order to investigate its suitability for geometry planning and image fusion. An algorithm for automated marker extraction in both MR and MP images and rigid registration was established. Results: The developed bimodal fiducial markers can be visualized by MRI and MPI and allow for geometry planning as well as automated registration and fusion of MR–MP images. Conclusions: To date, exact positioning of the object to be imaged within the field of view (FOV) and the assignment of reconstructed MPI signals to corresponding morphological regions has been difficult. The developed bimodal fiducial markers and the automated image registration algorithm help to overcome these difficulties.

  19. A new fiducial marker for Image-guided radiotherapy of prostate cancer: Clinical experience

    Energy Technology Data Exchange (ETDEWEB)

    Carl, Jesper; Nielsen, Jane; Holmberg, Mats; Hoejkjaer Larsen, Erik; Fabrin, Knud; Fisker, Rune V. (Dept. of Medical Physics, Oncology, Aalborg Hospital (Denmark))

    2008-08-15

    Background. A new fiducial marker for image guided radiotherapy (IGRT) based on a removable prostate stent made of Ni Ti has been developed during two previous clinical feasibility studies. The marker is currently being evaluated for IGRT treatment in a third clinical study. Method. The new marker is used to co-register MR and planning CT scans with high accuracy in the region around the prostate. The co-registered MR-CT volumes are used for delineation of GTV before planning. In each treatment session the IGRT system is used to position the patient before treatment. The IGRT system use a stereo pair of kV images matched to corresponding Digital Reconstructed Radiograms (DRR) from the planning CT scan. The match is done using mutual gray scale information. The pair of DRR's for positioning is created in the IGRT system with a threshold in the Look Up Table (LUT). The resulting match provides the necessary shift in couch coordinates to position the stent with an accuracy of 1-2 mm within the planned position. Results. At the present time 39 patients have received the new marker. Of the 39 one has migrated to the bladder. Deviations of more than 5 mm between CTV outlined on CT and MR are seen in several cases and in anterior-posterior (AP), left-right (LR) and cranial-caudal (CC) directions. Intra-fraction translation movements up to +/- 3 mm are seen as well. As the stent is also clearly visible on images taken with high voltage x-rays using electronic portal images devices (EPID), the positioning has been verified independently of the IGRT system. Discussion. The preliminary result of an on going clinical study of a Ni Ti prostate stent, potentially a new fiducial marker for image guided radiotherapy, looks promising. The risk of migration appears to be much lower compared to previous designs

  20. A new fiducial marker for Image-guided radiotherapy of prostate cancer: clinical experience.

    Science.gov (United States)

    Carl, Jesper; Nielsen, Jane; Holmberg, Mats; Højkjaer Larsen, Erik; Fabrin, Knud; Fisker, Rune V

    2008-01-01

    A new fiducial marker for image guided radiotherapy (IGRT) based on a removable prostate stent made of Ni Ti has been developed during two previous clinical feasibility studies. The marker is currently being evaluated for IGRT treatment in a third clinical study. The new marker is used to co-register MR and planning CT scans with high accuracy in the region around the prostate. The co-registered MR-CT volumes are used for delineation of GTV before planning. In each treatment session the IGRT system is used to position the patient before treatment. The IGRT system use a stereo pair of kV images matched to corresponding Digital Reconstructed Radiograms (DRR) from the planning CT scan. The match is done using mutual gray scale information. The pair of DRR's for positioning is created in the IGRT system with a threshold in the Look Up Table (LUT). The resulting match provides the necessary shift in couch coordinates to position the stent with an accuracy of 1-2 mm within the planned position. At the present time 39 patients have received the new marker. Of the 39 one has migrated to the bladder. Deviations of more than 5 mm between CTV outlined on CT and MR are seen in several cases and in anterior-posterior (AP), left-right (LR) and cranial-caudal (CC) directions. Intra-fraction translation movements up to +/- 3 mm are seen as well. As the stent is also clearly visible on images taken with high voltage x-rays using electronic portal images devices (EPID), the positioning has been verified independently of the IGRT system. The preliminary result of an on going clinical study of a Ni Ti prostate stent, potentially a new fiducial marker for image guided radiotherapy, looks promising. The risk of migration appears to be much lower compared to previous designs.

  1. A new fiducial marker for Image-guided radiotherapy of prostate cancer: Clinical experience

    International Nuclear Information System (INIS)

    Carl, Jesper; Nielsen, Jane; Holmberg, Mats; Hoejkjaer Larsen, Erik; Fabrin, Knud; Fisker, Rune V.

    2008-01-01

    Background. A new fiducial marker for image guided radiotherapy (IGRT) based on a removable prostate stent made of Ni Ti has been developed during two previous clinical feasibility studies. The marker is currently being evaluated for IGRT treatment in a third clinical study. Method. The new marker is used to co-register MR and planning CT scans with high accuracy in the region around the prostate. The co-registered MR-CT volumes are used for delineation of GTV before planning. In each treatment session the IGRT system is used to position the patient before treatment. The IGRT system use a stereo pair of kV images matched to corresponding Digital Reconstructed Radiograms (DRR) from the planning CT scan. The match is done using mutual gray scale information. The pair of DRR's for positioning is created in the IGRT system with a threshold in the Look Up Table (LUT). The resulting match provides the necessary shift in couch coordinates to position the stent with an accuracy of 1-2 mm within the planned position. Results. At the present time 39 patients have received the new marker. Of the 39 one has migrated to the bladder. Deviations of more than 5 mm between CTV outlined on CT and MR are seen in several cases and in anterior-posterior (AP), left-right (LR) and cranial-caudal (CC) directions. Intra-fraction translation movements up to +/- 3 mm are seen as well. As the stent is also clearly visible on images taken with high voltage x-rays using electronic portal images devices (EPID), the positioning has been verified independently of the IGRT system. Discussion. The preliminary result of an on going clinical study of a Ni Ti prostate stent, potentially a new fiducial marker for image guided radiotherapy, looks promising. The risk of migration appears to be much lower compared to previous designs

  2. Surface Nuclear Magnetic Resonance Imaging of Large Systems

    International Nuclear Information System (INIS)

    Weichman, P.B.; Lavely, E.M.; Ritzwoller, M.H.

    1999-01-01

    The general theory of surface NMR imaging of large electromagnetically active systems is considered, motivated by geophysical applications. A general imaging equation is derived for the NMR voltage response, valid for arbitrary transmitter and receiver loop geometry and arbitrary conductivity structure of the sample. When the conductivity grows to the point where the electromagnetic skin depth becomes comparable to the sample size, significant diffusive retardation effects occur that strongly affect the signal. Accounting for these now allows more accurate imaging than previously possible. It is shown that the time constant T 1 may in principle be inferred directly from the diffusive tail of the signal. copyright 1999 The American Physical Society

  3. Real-time automatic fiducial marker tracking in low contrast cine-MV images

    International Nuclear Information System (INIS)

    Lin, Wei-Yang; Lin, Shu-Fang; Yang, Sheng-Chang; Liou, Shu-Cheng; Nath, Ravinder; Liu Wu

    2013-01-01

    standard deviations of the results from the 6 researchers are 2.3 and 2.6 pixels. The proposed framework takes about 128 ms to detect four markers in the first MV images and about 23 ms to track these markers in each of the subsequent images. Conclusions: The unified framework for tracking of multiple markers presented here can achieve marker detection accuracy similar to manual detection even in low-contrast cine-MV images. It can cope with shape deformations of fiducial markers at different gantry angles. The fast processing speed reduces the image processing portion of the system latency, therefore can improve the performance of real-time motion compensation.

  4. Real-time automatic fiducial marker tracking in low contrast cine-MV images

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Wei-Yang; Lin, Shu-Fang; Yang, Sheng-Chang; Liou, Shu-Cheng; Nath, Ravinder; Liu Wu [Department of Computer Science and Information Engineering, National Chung Cheng University, Taiwan, 62102 (China); Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut 06510-3220 (United States)

    2013-01-15

    standard deviations of the results from the 6 researchers are 2.3 and 2.6 pixels. The proposed framework takes about 128 ms to detect four markers in the first MV images and about 23 ms to track these markers in each of the subsequent images. Conclusions: The unified framework for tracking of multiple markers presented here can achieve marker detection accuracy similar to manual detection even in low-contrast cine-MV images. It can cope with shape deformations of fiducial markers at different gantry angles. The fast processing speed reduces the image processing portion of the system latency, therefore can improve the performance of real-time motion compensation.

  5. The CEOS-Land Surface Imaging Constellation Portal for GEOSS: A resource for land surface imaging system information and data access

    Science.gov (United States)

    Holm, Thomas; Gallo, Kevin P.; Bailey, Bryan

    2010-01-01

    The Committee on Earth Observation Satellites is an international group that coordinates civil space-borne observations of the Earth, and provides the space component of the Global Earth Observing System of Systems (GEOSS). The CEOS Virtual Constellations concept was implemented in an effort to engage and coordinate disparate Earth observing programs of CEOS member agencies and ultimately facilitate their contribution in supplying the space-based observations required to satisfy the requirements of the GEOSS. The CEOS initially established Study Teams for four prototype constellations that included precipitation, land surface imaging, ocean surface topography, and atmospheric composition. The basic mission of the Land Surface Imaging (LSI) Constellation [1] is to promote the efficient, effective, and comprehensive collection, distribution, and application of space-acquired image data of the global land surface, especially to meet societal needs of the global population, such as those addressed by the nine Group on Earth Observations (GEO) Societal Benefit Areas (SBAs) of agriculture, biodiversity, climate, disasters, ecosystems, energy, health, water, and weather. The LSI Constellation Portal is the result of an effort to address important goals within the LSI Constellation mission and provide resources to assist in planning for future space missions that might further contribute to meeting those goals.

  6. Accuracy of a commercial optical 3D surface imaging system for realignment of patients for radiotherapy of the thorax

    International Nuclear Information System (INIS)

    Schoeffel, Philipp J; Harms, Wolfgang; Sroka-Perez, Gabriele; Schlegel, Wolfgang; Karger, Christian P

    2007-01-01

    Accurate and reproducible patient setup is a prerequisite to fractionated radiotherapy. To evaluate the applicability and technical performance of a commercial 3D surface imaging system for repositioning of breast cancer patients, measurements were performed in a rigid anthropomorphic phantom as well as in healthy volunteers. The camera system records a respiration-gated surface model of the imaged object, which may be registered to a previously recorded reference model. A transformation is provided, which may be applied to the treatment couch to correct the setup of the patient. The system showed a high stability and detected pre-defined shifts of phantoms and healthy volunteers with an accuracy of 0.40 ± 0.26 mm and 1.02 ± 0.51 mm, respectively (spatial deviation between pre-defined shift and suggested correction). The accuracy of the suggested rotational correction around the vertical axis was always better than 0.3 0 in phantom measurements and 0.8 0 in volunteers, respectively. Comparison of the suggested setup correction with that detected by a second and independently operated marker-based optical system provided consistent results. The results demonstrate that the camera system provides highly accurate setup corrections in a phantom and healthy volunteers. The most efficient use of the system for improving the setup accuracy in breast cancer patients has to be investigated in routine patient treatments

  7. Robustness of an artificially tailored fisheye imaging system with a curvilinear image surface

    Science.gov (United States)

    Lee, Gil Ju; Nam, Won Il; Song, Young Min

    2017-11-01

    Curved image sensors inspired by animal and insect eyes have provided a new development direction in next-generation digital cameras. It is known that natural fish eyes afford an extremely wide field of view (FOV) imaging due to the geometrical properties of the spherical lens and hemispherical retina. However, its inherent drawbacks, such as the low off-axis illumination and the fabrication difficulty of a 'dome-like' hemispherical imager, limit the development of bio-inspired wide FOV cameras. Here, a new type of fisheye imaging system is introduced that has simple lens configurations with a curvilinear image surface, while maintaining high off-axis illumination and a wide FOV. Moreover, through comparisons with commercial conventional fisheye designs, it is determined that the volume and required number of optical elements of the proposed design is practical while capturing the fundamental optical performances. Detailed design guidelines for tailoring the proposed optic system are also discussed.

  8. A method of surface marker location optimization for tumor motion estimation in lung stereotactic body radiation therapy

    International Nuclear Information System (INIS)

    Lu, Bo; Park, Justin C.; Fan, Qiyong; Kahler, Darren; Liu, Chihray; Chen, Yunmei

    2015-01-01

    prediction errors for the PCA method were not only smaller, but were also more stable than for the SOA method. Results obtained by imposing a series of random noises to the surrogates indicated that the PCA method was much more noise resistant than the SOA method. The marker position consistency tests using various combinations of 4DCT phases to construct the surrogates suggested that the marker position predictions of the PCA method were more consistent than those of the SOA method, in spite of surrogate construction. Marker distribution tests indicated that greater than 80% of the calculated marker positions fell into the high cross correlation and high motion magnitude regions for both of the algorithms. Conclusions: The PCA model is an accurate, efficient, robust, and practical model for solving the multimarker position optimization problem to predict lung tumor motion during SBRT treatments. Due to its generality, PCA model can also be applied to other imaging guidance system whichever using surface motion as the surrogates

  9. Automatic fuzzy inference system development for marker-based watershed segmentation

    International Nuclear Information System (INIS)

    Gonzalez, M A; Meschino, G J; Ballarin, V L

    2007-01-01

    Texture image segmentation is a constant challenge in digital image processing. The partition of an image into regions that allow the experienced observer to obtain the necessary information can be done using a Mathematical Morphology tool called the Watershed Transform. This transform is able to distinguish extremely complex objects and is easily adaptable to various kinds of images. The success of the Watershed Transform depends essentially on the existence of unequivocal markers for each of the objects of interest. The standard methods for marker detection are highly specific and complex when objects presenting great variability of shape, size and texture are processed. This paper proposes the automatic generation of a fuzzy inference system for marker detection using object selection done by the expert. This method allows applying the Watershed Transform to biomedical images with diferent kinds of texture. The results allow concluding that the method proposed is an effective tool for the application of the Watershed Transform

  10. Study of skin markers for magnetic resonance imaging examinations

    International Nuclear Information System (INIS)

    Takatsu, Yasuo; Umezaki, Yoshie; Miyati, Tosiaki; Yamamura, Kenichirou

    2013-01-01

    In magnetic resonance imaging (MRI), skin markers are used as a landmark in order to make plans for examinations. However, there isn't a lot of research about the material and shape of skin markers. The skin marker's essential elements are safety, good cost performance, high signal intensity for T 1 weighted image (T 1 WI) and T 2 weighted image (T 2 WI), and durable. In order to get a high signal-to-noise ratio (SNR) of T 1 WI and T 2 WI, baby oil, salad oil and olive oil were chosen, because these materials were easy to obtain and safe for the skin. The SNR of baby oil was the best. Baby oil was injected into the infusion tube, and the tube was solvent welded and cut by a heat sealer. In order to make ring shaped skin markers, both ends of the tube were stuck with adhesive tape. Three different diameters of markers were made (3, 5, 10 cmφ). Ring shaped skin markers were put on to surround the examination area, therefore, the edge of the examination area could be seen at every cross section. Using baby oil in the ring shaped infusion tube is simple, easy, and a highly useful skin marker. (author)

  11. A common-path phase-shift interferometry surface plasmon imaging system

    Science.gov (United States)

    Su, Y.-T.; Chen, Shean-Jen; Yeh, T.-L.

    2005-03-01

    A biosensing imaging system is proposed based on the integration of surface plasmon resonance (SPR) and common-path phase-shift interferometry (PSI) techniques to measure the two-dimensional spatial phase variation caused by biomolecular interactions upon a sensing chip. The SPR phase imaging system can offer high resolution and high-throughout screening capabilities to analyze microarray biomolecular interaction without the need for additional labeling. With the long-term stability advantage of the common-path PSI technique even with external disturbances such as mechanical vibration, buffer flow noise, and laser unstable issue, the system can match the demand of real-time kinetic study for biomolecular interaction analysis (BIA). The SPR-PSI imaging system has achieved a detection limit of 2×10-7 refraction index change, a long-term phase stability of 2.5x10-4π rms over four hours, and a spatial phase resolution of 10-3 π with a lateral resolution of 100μm.

  12. Active illumination based 3D surface reconstruction and registration for image guided medialization laryngoplasty

    Science.gov (United States)

    Jin, Ge; Lee, Sang-Joon; Hahn, James K.; Bielamowicz, Steven; Mittal, Rajat; Walsh, Raymond

    2007-03-01

    The medialization laryngoplasty is a surgical procedure to improve the voice function of the patient with vocal fold paresis and paralysis. An image guided system for the medialization laryngoplasty will help the surgeons to accurately place the implant and thus reduce the failure rates of the surgery. One of the fundamental challenges in image guided system is to accurately register the preoperative radiological data to the intraoperative anatomical structure of the patient. In this paper, we present a combined surface and fiducial based registration method to register the preoperative 3D CT data to the intraoperative surface of larynx. To accurately model the exposed surface area, a structured light based stereo vision technique is used for the surface reconstruction. We combined the gray code pattern and multi-line shifting to generate the intraoperative surface of the larynx. To register the point clouds from the intraoperative stage to the preoperative 3D CT data, a shape priori based ICP method is proposed to quickly register the two surfaces. The proposed approach is capable of tracking the fiducial markers and reconstructing the surface of larynx with no damage to the anatomical structure. We used off-the-shelf digital cameras, LCD projector and rapid 3D prototyper to develop our experimental system. The final RMS error in the registration is less than 1mm.

  13. Nonlaser-based 3D surface imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Shin-yee; Johnson, R.K.; Sherwood, R.J. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    3D surface imaging refers to methods that generate a 3D surface representation of objects of a scene under viewing. Laser-based 3D surface imaging systems are commonly used in manufacturing, robotics and biomedical research. Although laser-based systems provide satisfactory solutions for most applications, there are situations where non laser-based approaches are preferred. The issues that make alternative methods sometimes more attractive are: (1) real-time data capturing, (2) eye-safety, (3) portability, and (4) work distance. The focus of this presentation is on generating a 3D surface from multiple 2D projected images using CCD cameras, without a laser light source. Two methods are presented: stereo vision and depth-from-focus. Their applications are described.

  14. Surface Markers for Chondrogenic Determination: A Highlight of Synovium-Derived Stem Cells

    Directory of Open Access Journals (Sweden)

    Douglas D. Campbell

    2012-11-01

    Full Text Available Cartilage tissue engineering is a promising field in regenerative medicine that can provide substantial relief to people suffering from degenerative cartilage disease. Current research shows the greatest chondrogenic potential for healthy articular cartilage growth with minimal hypertrophic differentiation to be from mesenchymal stem cells (MSCs of synovial origin. These stem cells have the capacity for differentiation into multiple cell lineages related to mesenchymal tissue; however, evidence exists for cell surface markers that specify a greater potential for chondrogenesis than other differentiation fates. This review will examine relevant literature to summarize the chondrogenic differentiation capacities of tested synovium-derived stem cell (SDSC surface markers, along with a discussion about various other markers that may hold potential, yet require further investigation. With this information, a potential clinical benefit exists to develop a screening system for SDSCs that will produce the healthiest articular cartilage possible.

  15. A new robust markerless method for automatic image-to-patient registration in image-guided neurosurgery system.

    Science.gov (United States)

    Liu, Yinlong; Song, Zhijian; Wang, Manning

    2017-12-01

    Compared with the traditional point-based registration in the image-guided neurosurgery system, surface-based registration is preferable because it does not use fiducial markers before image scanning and does not require image acquisition dedicated for navigation purposes. However, most existing surface-based registration methods must include a manual step for coarse registration, which increases the registration time and elicits some inconvenience and uncertainty. A new automatic surface-based registration method is proposed, which applies 3D surface feature description and matching algorithm to obtain point correspondences for coarse registration and uses the iterative closest point (ICP) algorithm in the last step to obtain an image-to-patient registration. Both phantom and clinical data were used to execute automatic registrations and target registration error (TRE) calculated to verify the practicality and robustness of the proposed method. In phantom experiments, the registration accuracy was stable across different downsampling resolutions (18-26 mm) and different support radii (2-6 mm). In clinical experiments, the mean TREs of two patients by registering full head surfaces were 1.30 mm and 1.85 mm. This study introduced a new robust automatic surface-based registration method based on 3D feature matching. The method achieved sufficient registration accuracy with different real-world surface regions in phantom and clinical experiments.

  16. Simulation of Specular Surface Imaging Based on Computer Graphics: Application on a Vision Inspection System

    Directory of Open Access Journals (Sweden)

    Seulin Ralph

    2002-01-01

    Full Text Available This work aims at detecting surface defects on reflecting industrial parts. A machine vision system, performing the detection of geometric aspect surface defects, is completely described. The revealing of defects is realized by a particular lighting device. It has been carefully designed to ensure the imaging of defects. The lighting system simplifies a lot the image processing for defect segmentation and so a real-time inspection of reflective products is possible. To bring help in the conception of imaging conditions, a complete simulation is proposed. The simulation, based on computer graphics, enables the rendering of realistic images. Simulation provides here a very efficient way to perform tests compared to the numerous attempts of manual experiments.

  17. Clinical use of computed tomography and surface markers to assist internal fixation within the equine hoof.

    Science.gov (United States)

    Gasiorowski, Janik C; Richardson, Dean W

    2015-02-01

    To describe clinical use of computed tomography (CT) and hoof surface markers to facilitate internal fixation within the confines of the hoof wall. Retrospective case series. Horses (n = 16) that had CT-guided internal fixation of the distal phalanx (DP) or distal sesamoid bone (DSB). Drill bit entry point and direction were planned from CT image series performed on hooves with grids of barium paste dots at proposed entry and projected exit sites. Post-implantation CT images were obtained to check screw position and length as well as fracture reduction. Imaging, reduction, and surgical and general anesthesia times were evaluated. Outcome was recorded. Screw position and length were considered near optimal in all horses, with no consequential malposition of bits or screws. Fracture reduction was evident in all cases. Preoperative planning times (at least 2 CT image acquisitions and grid creation) ranged from 10 to 20 minutes. Surgery time ranged from 45 to 90 minutes (mean, 61 minutes) and general anesthesia time ranged from 115 to 220 minutes (mean, 171 minutes). The combination of CT and surface marker grids allowed accurate positioning of screws in clinical DP and DSB fractures. The technique was simple and rapid. An aiming device is useful for the technique. © Copyright 2014 by The American College of Veterinary Surgeons.

  18. A portable UV-fluorescence multispectral imaging system for the analysis of painted surfaces

    Science.gov (United States)

    Comelli, Daniela; Valentini, Gianluca; Nevin, Austin; Farina, Andrea; Toniolo, Lucia; Cubeddu, Rinaldo

    2008-08-01

    A portable fluorescence multispectral imaging system was developed and has been used for the analysis of artistic surfaces. The imaging apparatus exploits two UV lamps for fluorescence excitation and a liquid crystal tunable filter coupled to a low-noise charge coupled device as the image detector. The main features of the system are critically presented, outlining the assets, drawbacks, and practical considerations of portability. A multivariate statistical treatment of spectral data is further considered. Finally, the in situ analysis with the new apparatus of recently restored Renaissance wall paintings is presented.

  19. Apparatus and method of optical marker projection for the three-dimensional shape measurement

    Science.gov (United States)

    Chen, Zhe; Qu, Xinghua; Geng, Xin; Zhang, Fumin

    2015-08-01

    Optical photography measurement and three-dimensional (3-D) scanning measurement have been widely used in the field of the fast dimensional and surface metrology. In the measurement process, however, retro-reflective markers are often pasted on the surface in advance for image registration and positioning the 3-D measuring instruments. For the large-scale workpiece with freeform surface, the process of pasting markers is time consuming, which reduces the measurement efficiency. Meanwhile, the measurement precision is impaired owing to the thickness of the marker. In this paper, we propose a system that projects two-dimensional (2-D) array optical markers with uniform energy on the surface of the workpiece instead of pasting retro-reflective markers, which achieves large-range and automated optical projection of the mark points. In order to conjunction with the 3-D handheld scanner belonging to our team, we develop an apparatus of optical marker projection, which is mainly composed of the high-power laser, the optical beam expander system, adjustable aperture stop and Dammann grating of dibasic spectrophotometric device. The projection apparatus can achieve the function of beams of 15 * 15 uniformly light of the two-dimensional lattice. And it's much cheaper than the existing systems.

  20. SU-E-J-219: Quantitative Evaluation of Motion Effects On Accuracy of Image-Guided Radiotherapy with Fiducial Markers Using CT Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ali, I; Oyewale, S; Ahmad, S; Algan, O [University of Oklahoma Health Sciences, Oklahoma City, OK (United States); Alsbou, N [Department of Electrical and Computer Engineering, Ada, OH (United States)

    2014-06-01

    Purpose: To investigate quantitatively patient motion effects on the localization accuracy of image-guided radiation with fiducial markers using axial CT (ACT), helical CT (HCT) and cone-beam CT (CBCT) using modeling and experimental phantom studies. Methods: Markers with different lengths (2.5 mm, 5 mm, 10 mm, and 20 mm) were inserted in a mobile thorax phantom which was imaged using ACT, HCT and CBCT. The phantom moved with sinusoidal motion with amplitudes ranging 0–20 mm and a frequency of 15 cycles-per-minute. Three parameters that include: apparent marker lengths, center position and distance between the centers of the markers were measured in the different CT images of the mobile phantom. A motion mathematical model was derived to predict the variations in the previous three parameters and their dependence on the motion in the different imaging modalities. Results: In CBCT, the measured marker lengths increased linearly with increase in motion amplitude. For example, the apparent length of the 10 mm marker was about 20 mm when phantom moved with amplitude of 5 mm. Although the markers have elongated, the center position and the distance between markers remained at the same position for different motion amplitudes in CBCT. These parameters were not affected by motion frequency and phase in CBCT. In HCT and ACT, the measured marker length, center and distance between markers varied irregularly with motion parameters. The apparent lengths of the markers varied with inverse of the phantom velocity which depends on motion frequency and phase. Similarly the center position and distance between markers varied inversely with phantom speed. Conclusion: Motion may lead to variations in maker length, center position and distance between markers using CT imaging. These effects should be considered in patient setup using image-guided radiation therapy based on fiducial markers matching using 2D-radiographs or volumetric CT imaging.

  1. SU-E-J-219: Quantitative Evaluation of Motion Effects On Accuracy of Image-Guided Radiotherapy with Fiducial Markers Using CT Imaging

    International Nuclear Information System (INIS)

    Ali, I; Oyewale, S; Ahmad, S; Algan, O; Alsbou, N

    2014-01-01

    Purpose: To investigate quantitatively patient motion effects on the localization accuracy of image-guided radiation with fiducial markers using axial CT (ACT), helical CT (HCT) and cone-beam CT (CBCT) using modeling and experimental phantom studies. Methods: Markers with different lengths (2.5 mm, 5 mm, 10 mm, and 20 mm) were inserted in a mobile thorax phantom which was imaged using ACT, HCT and CBCT. The phantom moved with sinusoidal motion with amplitudes ranging 0–20 mm and a frequency of 15 cycles-per-minute. Three parameters that include: apparent marker lengths, center position and distance between the centers of the markers were measured in the different CT images of the mobile phantom. A motion mathematical model was derived to predict the variations in the previous three parameters and their dependence on the motion in the different imaging modalities. Results: In CBCT, the measured marker lengths increased linearly with increase in motion amplitude. For example, the apparent length of the 10 mm marker was about 20 mm when phantom moved with amplitude of 5 mm. Although the markers have elongated, the center position and the distance between markers remained at the same position for different motion amplitudes in CBCT. These parameters were not affected by motion frequency and phase in CBCT. In HCT and ACT, the measured marker length, center and distance between markers varied irregularly with motion parameters. The apparent lengths of the markers varied with inverse of the phantom velocity which depends on motion frequency and phase. Similarly the center position and distance between markers varied inversely with phantom speed. Conclusion: Motion may lead to variations in maker length, center position and distance between markers using CT imaging. These effects should be considered in patient setup using image-guided radiation therapy based on fiducial markers matching using 2D-radiographs or volumetric CT imaging

  2. Real-time segmentation of multiple implanted cylindrical liver markers in kilovoltage and megavoltage x-ray images

    DEFF Research Database (Denmark)

    Fledelius, Walther; Worm, Esben Schjødt; Høyer, Morten

    2014-01-01

    (CBCT) projections, for real-time motion management. Thirteen patients treated with conformal stereotactic body radiation therapy in three fractions had 2-3 cylindrical gold markers implanted in the liver prior to treatment. At each fraction, the projection images of a pre-treatment CBCT scan were used...... for automatic generation of a 3D marker model that consisted of the size, orientation, and estimated 3D trajectory of each marker during the CBCT scan. The 3D marker model was used for real-time template based segmentation in subsequent x-ray images by projecting each marker's 3D shape and likely 3D motion...... range onto the imager plane. The segmentation was performed in intra-treatment kV images (526 marker traces, 92 097 marker projections) and MV images (88 marker traces, 22 382 marker projections), and in post-treatment CBCT projections (42 CBCT scans, 71 381 marker projections). 227 kV marker traces...

  3. A vision-based automated guided vehicle system with marker recognition for indoor use.

    Science.gov (United States)

    Lee, Jeisung; Hyun, Chang-Ho; Park, Mignon

    2013-08-07

    We propose an intelligent vision-based Automated Guided Vehicle (AGV) system using fiduciary markers. In this paper, we explore a low-cost, efficient vehicle guiding method using a consumer grade web camera and fiduciary markers. In the proposed method, the system uses fiduciary markers with a capital letter or triangle indicating direction in it. The markers are very easy to produce, manipulate, and maintain. The marker information is used to guide a vehicle. We use hue and saturation values in the image to extract marker candidates. When the known size fiduciary marker is detected by using a bird's eye view and Hough transform, the positional relation between the marker and the vehicle can be calculated. To recognize the character in the marker, a distance transform is used. The probability of feature matching was calculated by using a distance transform, and a feature having high probability is selected as a captured marker. Four directional signals and 10 alphabet features are defined and used as markers. A 98.87% recognition rate was achieved in the testing phase. The experimental results with the fiduciary marker show that the proposed method is a solution for an indoor AGV system.

  4. Portable hyperspectral fluorescence imaging system for detection of biofilms on stainless steel surfaces

    Science.gov (United States)

    Jun, Won; Lee, Kangjin; Millner, Patricia; Sharma, Manan; Chao, Kuanglin; Kim, Moon S.

    2008-04-01

    A rapid nondestructive technology is needed to detect bacterial contamination on the surfaces of food processing equipment to reduce public health risks. A portable hyperspectral fluorescence imaging system was used to evaluate potential detection of microbial biofilm on stainless steel typically used in the manufacture of food processing equipment. Stainless steel coupons were immersed in bacterium cultures, such as E. coli, Pseudomonas pertucinogena, Erwinia chrysanthemi, and Listeria innocula. Following a 1-week exposure, biofilm formations were assessed using fluorescence imaging. In addition, the effects on biofilm formation from both tryptic soy broth (TSB) and M9 medium with casamino acids (M9C) were examined. TSB grown cells enhance biofilm production compared with M9C-grown cells. Hyperspectral fluorescence images of the biofilm samples, in response to ultraviolet-A (320 to 400 nm) excitation, were acquired from approximately 416 to 700 nm. Visual evaluation of individual images at emission peak wavelengths in the blue revealed the most contrast between biofilms and stainless steel coupons. Two-band ratios compared with the single-band images increased the contrast between the biofilm forming area and stainless steel coupon surfaces. The 444/588 nm ratio images exhibited the greatest contrast between the biofilm formations and stainless coupon surfaces.

  5. A trial fabrication of activity standard surface sources and positional standard surface sources for an imaging plate system

    International Nuclear Information System (INIS)

    Sato, Yasushi; Hino, Yoshio; Yamada, Takahiro; Matsumoto, Mikio

    2003-01-01

    An imaging plate system can detect low level activity, but quantitative analysis is difficult because there are no adequate standard surface sources. A new fabrication method was developed for standard surface sources by printing on a sheet of paper using an ink-jet printer with inks in which a radioactive material was mixed. The fabricated standard surface sources had high uniformity, high positional resolution arbitrary shapes and a broad intensity range. The standard sources were used for measurement of surface activity as an application. (H. Yokoo)

  6. Real-time segmentation of multiple implanted cylindrical liver markers in kilovoltage and megavoltage x-ray images

    International Nuclear Information System (INIS)

    Fledelius, W; Worm, E; Høyer, M; Grau, C; Poulsen, P R

    2014-01-01

    Gold markers implanted in or near a tumor can be used as x-ray visible landmarks for image based tumor localization. The aim of this study was to develop and demonstrate fast and reliable real-time segmentation of multiple liver tumor markers in intra-treatment kV and MV images and in cone-beam CT (CBCT) projections, for real-time motion management. Thirteen patients treated with conformal stereotactic body radiation therapy in three fractions had 2–3 cylindrical gold markers implanted in the liver prior to treatment. At each fraction, the projection images of a pre-treatment CBCT scan were used for automatic generation of a 3D marker model that consisted of the size, orientation, and estimated 3D trajectory of each marker during the CBCT scan. The 3D marker model was used for real-time template based segmentation in subsequent x-ray images by projecting each marker's 3D shape and likely 3D motion range onto the imager plane. The segmentation was performed in intra-treatment kV images (526 marker traces, 92 097 marker projections) and MV images (88 marker traces, 22 382 marker projections), and in post-treatment CBCT projections (42 CBCT scans, 71 381 marker projections). 227 kV marker traces with low mean contrast-to-noise ratio were excluded as markers were not visible due to MV scatter. Online segmentation times measured for a limited dataset were used for estimating real-time segmentation times for all images. The percentage of detected markers was 94.8% (kV), 96.1% (MV), and 98.6% (CBCT). For the detected markers, the real-time segmentation was erroneous in 0.2–0.31% of the cases. The mean segmentation time per marker was 5.6 ms [2.1–12 ms] (kV), 5.5 ms [1.6–13 ms] (MV), and 6.5 ms [1.8–15 ms] (CBCT). Fast and reliable real-time segmentation of multiple liver tumor markers in intra-treatment kV and MV images and in CBCT projections was demonstrated for a large dataset. (paper)

  7. Quantification of the 3D relative movement of external marker sets vs. bones based on magnetic resonance imaging.

    Science.gov (United States)

    Sangeux, M; Marin, F; Charleux, F; Dürselen, L; Ho Ba Tho, M C

    2006-11-01

    Most in vivo knee kinematic analyses are based on external markers attached to the shank and the thigh. Literature data show that markers positioning and soft tissues artifacts affect the kinematic parameters of the bones true movement. Most of the techniques of quantification used were invasive. The aim of the present study was to develop and apply a non-invasive methodology to compute the relative movement between the bones and the markers. Magnetic resonance imaging acquisitions were performed on the right knee of eleven volunteers without knee injury. The subjects were equipped with external magnetic resonance imaging-compatible marker sets. A foot drive device allowed the subjects to perform an actively loaded knee extension. The whole volume of the subject's knee was processed for four sequentially held knee flexion positions during the knee movement. The bones and external marker sets geometry were reconstructed from magnetic resonance imaging images. Then a registration algorithm was applied to the bones and the relative movement of the thigh and shank marker sets with respect to their underlying bones was computed. The protocol resulted in a good geometrical accuracy and reproducibility. Marker sets movement differ from that of the bones with a maximum of 22 mm in translation and 15 degrees in rotation and it affects the knee kinematics. Marker sets relative movement modify the knee movement finite helical axes direction (range 10-35 degrees ) and localization (range 0-40 mm). The methodology developed can evaluate external marker set system to be used for kinematic analysis in a clinical environment.

  8. Accuracy of an infrared marker-based patient positioning system (ExacTrac®) for stereotactic body radiotherapy in localizing the planned isocenter using fiducial markers

    Science.gov (United States)

    Montes-Rodríguez, María de los Ángeles; Hernández-Bojórquez, Mariana; Martínez-Gómez, Alma Angélica; Contreras-Pérez, Agustín; Negrete-Hernández, Ingrid Mireya; Hernández-Oviedo, Jorge Omar; Mitsoura, Eleni; Santiago-Concha, Bernardino Gabriel

    2014-11-01

    Stereotactic Body Radiation Therapy (SBRT) requires a controlled immobilization and position monitoring of patient and target. The purpose of this work is to analyze the performance of the imaging system ExacTrac® (ETX) using infrared and fiducial markers. Materials and methods: In order to assure the accuracy of isocenter localization, a Quality Assurance procedure was applied using an infrared marker-based positioning system. Scans were acquired of an inhouse-agar gel and solid water phantom with infrared spheres. In the inner part of the phantom, three reference markers were delineated as reference and one pellet was place internally; which was assigned as the isocenter. The iPlan® RT Dose treatment planning system. Images were exported to the ETX console. Images were acquired with the ETX to check the correctness of the isocenter placement. Adjustments were made in 6D the reference markers were used to fuse the images. Couch shifts were registered. The procedure was repeated for verification purposes. Results: The data recorded of the verifications in translational and rotational movements showed averaged 3D spatial uncertainties of 0.31 ± 0.42 mm respectively 0.82° ± 0.46° in the phantom and the first correction of these uncertainties were of 1.51 ± 1.14 mm respectively and 1.37° ± 0.61°. Conclusions: This study shows a high accuracy and repeatability in positioning the selected isocenter. The ETX-system for verifying the treatment isocenter position has the ability to monitor the tracing position of interest, making it possible to be used for SBRT positioning within uncertainty ≤1mm.

  9. Accuracy of an infrared marker-based patient positioning system (ExacTrac®) for stereotactic body radiotherapy in localizing the planned isocenter using fiducial markers

    Energy Technology Data Exchange (ETDEWEB)

    Montes-Rodríguez, María de los Ángeles, E-mail: angy24538@yahoo.com; Mitsoura, Eleni [Medical Physics Graduate Programme, Universidad Autónoma del Estado de México, Facultad de Medicina, Paseo Tollocan esquina Jesús Carranza Colonia Moderna de la Cruz, C.P. 50180, Toluca, Estado de México (Mexico); Hernández-Bojórquez, Mariana; Martínez-Gómez, Alma Angélica; Contreras-Pérez, Agustín; Negrete-Hernández, Ingrid Mireya; Hernández-Oviedo, Jorge Omar; Santiago-Concha, Bernardino Gabriel [Centro de Cáncer ABC, The American British Cowdray Medical Center I.A.P. (CMABC), Calle Sur 136, no. 116, Colonia las Américas, C.P. 01120, México, D.F. (Mexico)

    2014-11-07

    Stereotactic Body Radiation Therapy (SBRT) requires a controlled immobilization and position monitoring of patient and target. The purpose of this work is to analyze the performance of the imaging system ExacTrac® (ETX) using infrared and fiducial markers. Materials and methods: In order to assure the accuracy of isocenter localization, a Quality Assurance procedure was applied using an infrared marker-based positioning system. Scans were acquired of an inhouse-agar gel and solid water phantom with infrared spheres. In the inner part of the phantom, three reference markers were delineated as reference and one pellet was place internally; which was assigned as the isocenter. The iPlan® RT Dose treatment planning system. Images were exported to the ETX console. Images were acquired with the ETX to check the correctness of the isocenter placement. Adjustments were made in 6D the reference markers were used to fuse the images. Couch shifts were registered. The procedure was repeated for verification purposes. Results: The data recorded of the verifications in translational and rotational movements showed averaged 3D spatial uncertainties of 0.31 ± 0.42 mm respectively 0.82° ± 0.46° in the phantom and the first correction of these uncertainties were of 1.51 ± 1.14 mm respectively and 1.37° ± 0.61°. Conclusions: This study shows a high accuracy and repeatability in positioning the selected isocenter. The ETX-system for verifying the treatment isocenter position has the ability to monitor the tracing position of interest, making it possible to be used for SBRT positioning within uncertainty ≤1mm.

  10. Validation of deformable image registration algorithms on CT images of ex vivo porcine bladders with fiducial markers

    Energy Technology Data Exchange (ETDEWEB)

    Wognum, S., E-mail: s.wognum@gmail.com; Heethuis, S. E.; Bel, A. [Department of Radiation Oncology, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Rosario, T. [Department of Radiation Oncology, VU University Medical Center, De Boelelaan 1117, 1081 HZ Amsterdam (Netherlands); Hoogeman, M. S. [Department of Radiation Oncology, Erasmus MC Cancer Institute, Erasmus Medical Center, Groene Hilledijk 301, 3075 EA Rotterdam (Netherlands)

    2014-07-15

    Purpose: The spatial accuracy of deformable image registration (DIR) is important in the implementation of image guided adaptive radiotherapy techniques for cancer in the pelvic region. Validation of algorithms is best performed on phantoms with fiducial markers undergoing controlled large deformations. Excised porcine bladders, exhibiting similar filling and voiding behavior as human bladders, provide such an environment. The aim of this study was to determine the spatial accuracy of different DIR algorithms on CT images ofex vivo porcine bladders with radiopaque fiducial markers applied to the outer surface, for a range of bladder volumes, using various accuracy metrics. Methods: Five excised porcine bladders with a grid of 30–40 radiopaque fiducial markers attached to the outer wall were suspended inside a water-filled phantom. The bladder was filled with a controlled amount of water with added contrast medium for a range of filling volumes (100–400 ml in steps of 50 ml) using a luer lock syringe, and CT scans were acquired at each filling volume. DIR was performed for each data set, with the 100 ml bladder as the reference image. Six intensity-based algorithms (optical flow or demons-based) implemented in theMATLAB platform DIRART, a b-spline algorithm implemented in the commercial software package VelocityAI, and a structure-based algorithm (Symmetric Thin Plate Spline Robust Point Matching) were validated, using adequate parameter settings according to values previously published. The resulting deformation vector field from each registration was applied to the contoured bladder structures and to the marker coordinates for spatial error calculation. The quality of the algorithms was assessed by comparing the different error metrics across the different algorithms, and by comparing the effect of deformation magnitude (bladder volume difference) per algorithm, using the Independent Samples Kruskal-Wallis test. Results: The authors found good structure

  11. Validation of deformable image registration algorithms on CT images of ex vivo porcine bladders with fiducial markers.

    Science.gov (United States)

    Wognum, S; Heethuis, S E; Rosario, T; Hoogeman, M S; Bel, A

    2014-07-01

    The spatial accuracy of deformable image registration (DIR) is important in the implementation of image guided adaptive radiotherapy techniques for cancer in the pelvic region. Validation of algorithms is best performed on phantoms with fiducial markers undergoing controlled large deformations. Excised porcine bladders, exhibiting similar filling and voiding behavior as human bladders, provide such an environment. The aim of this study was to determine the spatial accuracy of different DIR algorithms on CT images of ex vivo porcine bladders with radiopaque fiducial markers applied to the outer surface, for a range of bladder volumes, using various accuracy metrics. Five excised porcine bladders with a grid of 30-40 radiopaque fiducial markers attached to the outer wall were suspended inside a water-filled phantom. The bladder was filled with a controlled amount of water with added contrast medium for a range of filling volumes (100-400 ml in steps of 50 ml) using a luer lock syringe, and CT scans were acquired at each filling volume. DIR was performed for each data set, with the 100 ml bladder as the reference image. Six intensity-based algorithms (optical flow or demons-based) implemented in theMATLAB platform DIRART, a b-spline algorithm implemented in the commercial software package VelocityAI, and a structure-based algorithm (Symmetric Thin Plate Spline Robust Point Matching) were validated, using adequate parameter settings according to values previously published. The resulting deformation vector field from each registration was applied to the contoured bladder structures and to the marker coordinates for spatial error calculation. The quality of the algorithms was assessed by comparing the different error metrics across the different algorithms, and by comparing the effect of deformation magnitude (bladder volume difference) per algorithm, using the Independent Samples Kruskal-Wallis test. The authors found good structure accuracy without dependency on

  12. Validation of deformable image registration algorithms on CT images of ex vivo porcine bladders with fiducial markers

    International Nuclear Information System (INIS)

    Wognum, S.; Heethuis, S. E.; Bel, A.; Rosario, T.; Hoogeman, M. S.

    2014-01-01

    Purpose: The spatial accuracy of deformable image registration (DIR) is important in the implementation of image guided adaptive radiotherapy techniques for cancer in the pelvic region. Validation of algorithms is best performed on phantoms with fiducial markers undergoing controlled large deformations. Excised porcine bladders, exhibiting similar filling and voiding behavior as human bladders, provide such an environment. The aim of this study was to determine the spatial accuracy of different DIR algorithms on CT images ofex vivo porcine bladders with radiopaque fiducial markers applied to the outer surface, for a range of bladder volumes, using various accuracy metrics. Methods: Five excised porcine bladders with a grid of 30–40 radiopaque fiducial markers attached to the outer wall were suspended inside a water-filled phantom. The bladder was filled with a controlled amount of water with added contrast medium for a range of filling volumes (100–400 ml in steps of 50 ml) using a luer lock syringe, and CT scans were acquired at each filling volume. DIR was performed for each data set, with the 100 ml bladder as the reference image. Six intensity-based algorithms (optical flow or demons-based) implemented in theMATLAB platform DIRART, a b-spline algorithm implemented in the commercial software package VelocityAI, and a structure-based algorithm (Symmetric Thin Plate Spline Robust Point Matching) were validated, using adequate parameter settings according to values previously published. The resulting deformation vector field from each registration was applied to the contoured bladder structures and to the marker coordinates for spatial error calculation. The quality of the algorithms was assessed by comparing the different error metrics across the different algorithms, and by comparing the effect of deformation magnitude (bladder volume difference) per algorithm, using the Independent Samples Kruskal-Wallis test. Results: The authors found good structure

  13. Performance of a novel SQUID-based superconducting imaging-surface magnetoencephalography system

    Science.gov (United States)

    Kraus, R. H.; Volegov, P.; Maharajh, K.; Espy, M. A.; Matlashov, A. N.; Flynn, E. R.

    2002-03-01

    Performance for a recently completed whole-head magnetoencephalography system using a superconducting imaging surface (SIS) surrounding an array of 150 SQUID magnetometers is reported. The helmet-like SIS is hemispherical in shape with a brim. Conceptually, the SIS images nearby sources onto the SQUIDs while shielding sensors from distant “noise” sources. A finite element method (FEM) description using the as-built geometry was developed to describe the SIS effect on source fields by imposing B⊥( surface)=0 . Sensors consist of 8×8 mm 2 SQUID magnetometers with 0.84 nT/ Φ0 sensitivity and positions and orientations was found. Good agreement was found between modeled and measured shielding of the SQUIDs from sources external to the array showing significant frequency-independent shielding. Phantom localization precision was better than 0.5 mm at all locations with a mean of better than 0.3 mm.

  14. Fermi surface contours obtained from scanning tunneling microscope images around surface point defects

    International Nuclear Information System (INIS)

    Khotkevych-Sanina, N V; Kolesnichenko, Yu A; Van Ruitenbeek, J M

    2013-01-01

    We present a theoretical analysis of the standing wave patterns in scanning tunneling microscope (STM) images, which occur around surface point defects. We consider arbitrary dispersion relations for the surface states and calculate the conductance for a system containing a small-size tunnel contact and a surface impurity. We find rigorous theoretical relations between the interference patterns in the real-space STM images, their Fourier transforms and the Fermi contours of two-dimensional electrons. We propose a new method for reconstructing Fermi contours of surface electron states, directly from the real-space STM images around isolated surface defects. (paper)

  15. Quantification and comparison of visibility and image artifacts of a new liquid fiducial marker in a lung phantom for image-guided radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Scherman Rydhög, Jonas, E-mail: per.jonas.scherman.rydhoeg@regionh.dk; Munck af Rosenschöld, Per [Department of Oncology, Section of Radiotherapy, 3994, Rigshospitalet, Blegdamsvej 9, Copenhagen 2100, Denmark and Niels Bohr Institute, University of Copenhagen, Blegdamsvej 17, Copenhagen 2100 (Denmark); Irming Jølck, Rasmus; Andresen, Thomas Lars [DTU Nanotech, Department of Micro- and Nanotechnology, Center for Nanomedicine and Theranostics, Technical University of Denmark, Building 423, Kongens Lyngby 2800 (Denmark)

    2015-06-15

    Purpose: A new biodegradable liquid fiducial marker was devised to allow for easy insertion in lung tumors using thin needles. The purpose of this study was to evaluate the visibility of the liquid fiducial markers for image-guided radiation therapy and compare to existing solid fiducial markers and to one existing liquid fiducial marker currently commercially available. Methods: Fiducial marker visibility was quantified in terms of contrast to noise ratio (CNR) on planar kilovoltage x-ray images in a thorax phantom for different concentrations of the radio-opaque component of the new liquid fiducial marker, four solid fiducial markers, and one existing liquid fiducial marker. Additionally, the image artifacts produced on computer tomography (CT) and cone-beam CT (CBCT) of all fiducial markers were quantified. Results: The authors found that the new liquid fiducial marker with the highest concentration of the radio-opaque component had a CNR > 2.05 for 62/63 exposures, which compared favorably to the existing solid fiducial markers and to the existing liquid fiducial marker evaluated. On CT and CBCT, the new liquid fiducial marker with the highest concentration produced lower streaking index artifact (30 and 14, respectively) than the solid gold markers (113 and 20, respectively) and the existing liquid fiducial marker (39 and 20, respectively). The size of the image artifact was larger for all of the liquid fiducial markers compared to the solid fiducial markers because of their larger physical size. Conclusions: The visibility and the image artifacts produced by the new liquid fiducial markers were comparable to existing solid fiducial markers and the existing liquid fiducial marker. The authors conclude that the new liquid fiducial marker represents an alternative to the fiducial markers tested.

  16. The Colour and Stereo Surface Imaging System (CaSSIS) for the ExoMars Trace Gas Orbiter

    Science.gov (United States)

    Thomas, N.; Cremonese, G.; Ziethe, R.; Gerber, M.; Brändli, M.; Bruno, G.; Erismann, M.; Gambicorti, L.; Gerber, T.; Ghose, K.; Gruber, M.; Gubler, P.; Mischler, H.; Jost, J.; Piazza, D.; Pommerol, A.; Rieder, M.; Roloff, V.; Servonet, A.; Trottmann, W.; Uthaicharoenpong, T.; Zimmermann, C.; Vernani, D.; Johnson, M.; Pelò, E.; Weigel, T.; Viertl, J.; De Roux, N.; Lochmatter, P.; Sutter, G.; Casciello, A.; Hausner, T.; Ficai Veltroni, I.; Da Deppo, V.; Orleanski, P.; Nowosielski, W.; Zawistowski, T.; Szalai, S.; Sodor, B.; Tulyakov, S.; Troznai, G.; Banaskiewicz, M.; Bridges, J.C.; Byrne, S.; Debei, S.; El-Maarry, M. R.; Hauber, E.; Hansen, C.J.; Ivanov, A.; Keszthelyil, L.; Kirk, Randolph L.; Kuzmin, R.; Mangold, N.; Marinangeli, L.; Markiewicz, W. J.; Massironi, M.; McEwen, A.S.; Okubo, Chris H.; Tornabene, L.L.; Wajer, P.; Wray, J.J.

    2017-01-01

    The Colour and Stereo Surface Imaging System (CaSSIS) is the main imaging system onboard the European Space Agency’s ExoMars Trace Gas Orbiter (TGO) which was launched on 14 March 2016. CaSSIS is intended to acquire moderately high resolution (4.6 m/pixel) targeted images of Mars at a rate of 10–20 images per day from a roughly circular orbit 400 km above the surface. Each image can be acquired in up to four colours and stereo capability is foreseen by the use of a novel rotation mechanism. A typical product from one image acquisition will be a 9.5 km×∼45 km">9.5 km×∼45 km9.5 km×∼45 km swath in full colour and stereo in one over-flight of the target thereby reducing atmospheric influences inherent in stereo and colour products from previous high resolution imagers. This paper describes the instrument including several novel technical solutions required to achieve the scientific requirements.

  17. Marker Registration Technique for Handwritten Text Marker in Augmented Reality Applications

    Science.gov (United States)

    Thanaborvornwiwat, N.; Patanukhom, K.

    2018-04-01

    Marker registration is a fundamental process to estimate camera poses in marker-based Augmented Reality (AR) systems. We developed AR system that creates correspondence virtual objects on handwritten text markers. This paper presents a new method for registration that is robust for low-content text markers, variation of camera poses, and variation of handwritten styles. The proposed method uses Maximally Stable Extremal Regions (MSER) and polygon simplification for a feature point extraction. The experiment shows that we need to extract only five feature points per image which can provide the best registration results. An exhaustive search is used to find the best matching pattern of the feature points in two images. We also compared performance of the proposed method to some existing registration methods and found that the proposed method can provide better accuracy and time efficiency.

  18. Method for automatic localization of MR-visible markers using morphological image processing and conventional pulse sequences: feasibility for image-guided procedures.

    Science.gov (United States)

    Busse, Harald; Trampel, Robert; Gründer, Wilfried; Moche, Michael; Kahn, Thomas

    2007-10-01

    To evaluate the feasibility and accuracy of an automated method to determine the 3D position of MR-visible markers. Inductively coupled RF coils were imaged in a whole-body 1.5T scanner using the body coil and two conventional gradient echo sequences (FLASH and TrueFISP) and large imaging volumes up to (300 mm(3)). To minimize background signals, a flip angle of approximately 1 degrees was used. Morphological 2D image processing in orthogonal scan planes was used to determine the 3D positions of a configuration of three fiducial markers (FMC). The accuracies of the marker positions and of the orientation of the plane defined by the FMC were evaluated at various distances r(M) from the isocenter. Fiducial marker detection with conventional equipment (pulse sequences, imaging coils) was very reliable and highly reproducible over a wide range of experimental conditions. For r(M) markers by morphological image processing is feasible, simple, and very accurate. In combination with safe wireless markers, the method is found to be useful for image-guided procedures. (c) 2007 Wiley-Liss, Inc.

  19. Parallel scan hyperspectral fluorescence imaging system and biomedical application for microarrays

    International Nuclear Information System (INIS)

    Liu Zhiyi; Ma Suihua; Liu Le; Guo Jihua; He Yonghong; Ji Yanhong

    2011-01-01

    Microarray research offers great potential for analysis of gene expression profile and leads to greatly improved experimental throughput. A number of instruments have been reported for microarray detection, such as chemiluminescence, surface plasmon resonance, and fluorescence markers. Fluorescence imaging is popular for the readout of microarrays. In this paper we develop a quasi-confocal, multichannel parallel scan hyperspectral fluorescence imaging system for microarray research. Hyperspectral imaging records the entire emission spectrum for every voxel within the imaged area in contrast to recording only fluorescence intensities of filter-based scanners. Coupled with data analysis, the recorded spectral information allows for quantitative identification of the contributions of multiple, spectrally overlapping fluorescent dyes and elimination of unwanted artifacts. The mechanism of quasi-confocal imaging provides a high signal-to-noise ratio, and parallel scan makes this approach a high throughput technique for microarray analysis. This system is improved with a specifically designed spectrometer which can offer a spectral resolution of 0.2 nm, and operates with spatial resolutions ranging from 2 to 30 μm . Finally, the application of the system is demonstrated by reading out microarrays for identification of bacteria.

  20. Applying a new mammographic imaging marker to predict breast cancer risk

    Science.gov (United States)

    Aghaei, Faranak; Danala, Gopichandh; Hollingsworth, Alan B.; Stoug, Rebecca G.; Pearce, Melanie; Liu, Hong; Zheng, Bin

    2018-02-01

    Identifying and developing new mammographic imaging markers to assist prediction of breast cancer risk has been attracting extensive research interest recently. Although mammographic density is considered an important breast cancer risk, its discriminatory power is lower for predicting short-term breast cancer risk, which is a prerequisite to establish a more effective personalized breast cancer screening paradigm. In this study, we presented a new interactive computer-aided detection (CAD) scheme to generate a new quantitative mammographic imaging marker based on the bilateral mammographic tissue density asymmetry to predict risk of cancer detection in the next subsequent mammography screening. An image database involving 1,397 women was retrospectively assembled and tested. Each woman had two digital mammography screenings namely, the "current" and "prior" screenings with a time interval from 365 to 600 days. All "prior" images were originally interpreted negative. In "current" screenings, these cases were divided into 3 groups, which include 402 positive, 643 negative, and 352 biopsy-proved benign cases, respectively. There is no significant difference of BIRADS based mammographic density ratings between 3 case groups (p cancer detection in the "current" screening. Study demonstrated that this new imaging marker had potential to yield significantly higher discriminatory power to predict short-term breast cancer risk.

  1. Automated vehicle guidance using discrete reference markers. [road surface steering techniques

    Science.gov (United States)

    Johnston, A. R.; Assefi, T.; Lai, J. Y.

    1979-01-01

    Techniques for providing steering control for an automated vehicle using discrete reference markers fixed to the road surface are investigated analytically. Either optical or magnetic approaches can be used for the sensor, which generates a measurement of the lateral offset of the vehicle path at each marker to form the basic data for steering control. Possible mechanizations of sensor and controller are outlined. Techniques for handling certain anomalous conditions, such as a missing marker, or loss of acquisition, and special maneuvers, such as u-turns and switching, are briefly discussed. A general analysis of the vehicle dynamics and the discrete control system is presented using the state variable formulation. Noise in both the sensor measurement and in the steering servo are accounted for. An optimal controller is simulated on a general purpose computer, and the resulting plots of vehicle path are presented. Parameters representing a small multipassenger tram were selected, and the simulation runs show response to an erroneous sensor measurement and acquisition following large initial path errors.

  2. Biomedical wellness monitoring system based upon molecular markers

    Science.gov (United States)

    Ingram, Whitney

    2012-06-01

    We wish to assist caretakers with a sensor monitoring systems for tracking the physiological changes of homealone patients. One goal is seeking biomarkers and modern imaging sensors like stochastic optical reconstruction microscopy (STORM), which has achieved visible imaging at the nano-scale range. Imaging techniques like STORM can be combined with a fluorescent functional marker in a system to capture the early transformation signs from wellness to illness. By exploiting both microscopic knowledge of genetic pre-disposition and the macroscopic influence of epigenetic factors we hope to target these changes remotely. We adopt dual spectral infrared imaging for blind source separation (BSS) to detect angiogenesis changes and use laser speckle imaging for hypertension blood flow monitoring. Our design hypothesis for the monitoring system is guided by the user-friendly, veteran-preferred "4-Non" principles (noninvasive, non-contact, non-tethered, non-stop-to-measure) and by the NIH's "4Ps" initiatives (predictive, personalized, preemptive, and participatory). We augment the potential storage system with the recent know-how of video Compressive Sampling (CSp) from surveillance cameras. In CSp only major changes are saved, which reduces the manpower cost of caretakers and medical analysts. This CSp algorithm is based on smart associative memory (AM) matrix storage: change features and detailed scenes are written by the outer-product and read by the inner product without the usual Harsh index for image searching. From this approach, we attempt to design an effective household monitoring approach to save healthcare costs and maintain the quality of life of seniors.

  3. Whole surface image reconstruction for machine vision inspection of fruit

    Science.gov (United States)

    Reese, D. Y.; Lefcourt, A. M.; Kim, M. S.; Lo, Y. M.

    2007-09-01

    Automated imaging systems offer the potential to inspect the quality and safety of fruits and vegetables consumed by the public. Current automated inspection systems allow fruit such as apples to be sorted for quality issues including color and size by looking at a portion of the surface of each fruit. However, to inspect for defects and contamination, the whole surface of each fruit must be imaged. The goal of this project was to develop an effective and economical method for whole surface imaging of apples using mirrors and a single camera. Challenges include mapping the concave stem and calyx regions. To allow the entire surface of an apple to be imaged, apples were suspended or rolled above the mirrors using two parallel music wires. A camera above the apples captured 90 images per sec (640 by 480 pixels). Single or multiple flat or concave mirrors were mounted around the apple in various configurations to maximize surface imaging. Data suggest that the use of two flat mirrors provides inadequate coverage of a fruit but using two parabolic concave mirrors allows the entire surface to be mapped. Parabolic concave mirrors magnify images, which results in greater pixel resolution and reduced distortion. This result suggests that a single camera with two parabolic concave mirrors can be a cost-effective method for whole surface imaging.

  4. Initial results of tests of depth markers as a surface diagnostic for fusion devices

    Directory of Open Access Journals (Sweden)

    L.A. Kesler

    2017-08-01

    Full Text Available The Accelerator-Based In Situ Materials Surveillance (AIMS diagnostic was developed to perform in situ ion beam analysis (IBA on Alcator C-Mod in August 2012 to study divertor surfaces between shots. These results were limited to studying low-Z surface properties, because the Coulomb barrier precludes nuclear reactions between high-Z elements and the ∼1 MeV AIMS deuteron beam. In order to measure the high-Z erosion, a technique using deuteron-induced gamma emission and a low-Z depth marker is being developed. To determine the depth of the marker while eliminating some uncertainty due to beam and detector parameters, the energy dependence of the ratio of two gamma yields produced from the same depth marker will be used to determine the ion beam energy loss in the surface, and thus the thickness of the high-Z surface. This paper presents the results of initial trials of using an implanted depth marker layer with a deuteron beam and the method of ratios. First tests of a lithium depth marker proved unsuccessful due to the production of conflicting gamma peaks, among other issues. However, successful trials with a boron depth marker show that it is possible to measure the depth of the marker layer with the method of gamma yield ratios.

  5. Automatic tracking of implanted fiducial markers in cone beam CT projection images

    International Nuclear Information System (INIS)

    Marchant, T. E.; Skalski, A.; Matuszewski, B. J.

    2012-01-01

    Purpose: This paper describes a novel method for simultaneous intrafraction tracking of multiple fiducial markers. Although the proposed method is generic and can be adopted for a number of applications including fluoroscopy based patient position monitoring and gated radiotherapy, the tracking results presented in this paper are specific to tracking fiducial markers in a sequence of cone beam CT projection images. Methods: The proposed method is accurate and robust thanks to utilizing the mean shift and random sampling principles, respectively. The performance of the proposed method was evaluated with qualitative and quantitative methods, using data from two pancreatic and one prostate cancer patients and a moving phantom. The ground truth, for quantitative evaluation, was calculated based on manual tracking preformed by three observers. Results: The average dispersion of marker position error calculated from the tracking results for pancreas data (six markers tracked over 640 frames, 3840 marker identifications) was 0.25 mm (at iscoenter), compared with an average dispersion for the manual ground truth estimated at 0.22 mm. For prostate data (three markers tracked over 366 frames, 1098 marker identifications), the average error was 0.34 mm. The estimated tracking error in the pancreas data was < 1 mm (2 pixels) in 97.6% of cases where nearby image clutter was detected and in 100.0% of cases with no nearby image clutter. Conclusions: The proposed method has accuracy comparable to that of manual tracking and, in combination with the proposed batch postprocessing, superior robustness. Marker tracking in cone beam CT (CBCT) projections is useful for a variety of purposes, such as providing data for assessment of intrafraction motion, target tracking during rotational treatment delivery, motion correction of CBCT, and phase sorting for 4D CBCT.

  6. Autonomic markers of emotional processing: skin sympathetic nerve activity in humans during exposure to emotionally charged images.

    Science.gov (United States)

    Brown, Rachael; James, Cheree; Henderson, Luke A; Macefield, Vaughan G

    2012-01-01

    The sympathetic innervation of the skin primarily subserves thermoregulation, but the system has also been commandeered as a means of expressing emotion. While it is known that the level of skin sympathetic nerve activity (SSNA) is affected by anxiety, the majority of emotional studies have utilized the galvanic skin response as a means of inferring increases in SSNA. The purpose of the present study was to characterize the changes in SSNA when showing subjects neutral or emotionally charged images from the International Affective Picture System (IAPS). SSNA was recorded via tungsten microelectrodes inserted into cutaneous fascicles of the common peroneal nerve in ten subjects. Neutral images, positively charged images (erotica) or negatively charged images (mutilation) were presented in blocks of fifteen images of a specific type, each block lasting 2 min. Images of erotica or mutilation were presented in a quasi-random fashion, each block following a block of neutral images. Both images of erotica or images of mutilation caused significant increases in SSNA, but the increases in SSNA were greater for mutilation. The increases in SSNA were often coupled with sweat release and cutaneous vasoconstriction; however, these markers were not always consistent with the SSNA increases. We conclude that SSNA, comprising cutaneous vasoconstrictor and sudomotor activity, increases with both positively charged and negatively charged emotional images. Measurement of SSNA provides a more comprehensive assessment of sympathetic outflow to the skin than does the use of sweat release alone as a marker of emotional processing.

  7. Mixed Marker-Based/Marker-Less Visual Odometry System for Mobile Robots

    Directory of Open Access Journals (Sweden)

    Fabrizio Lamberti

    2013-05-01

    Full Text Available Abstract When moving in generic indoor environments, robotic platforms generally rely solely on information provided by onboard sensors to determine their position and orientation. However, the lack of absolute references often leads to the introduction of severe drifts in estimates computed, making autonomous operations really hard to accomplish. This paper proposes a solution to alleviate the impact of the above issues by combining two vision-based pose estimation techniques working on relative and absolute coordinate systems, respectively. In particular, the unknown ground features in the images that are captured by the vertical camera of a mobile platform are processed by a vision-based odometry algorithm, which is capable of estimating the relative frame-to-frame movements. Then, errors accumulated in the above step are corrected using artificial markers displaced at known positions in the environment. The markers are framed from time to time, which allows the robot to maintain the drifts bounded by additionally providing it with the navigation commands needed for autonomous flight. Accuracy and robustness of the designed technique are demonstrated using an off-the-shelf quadrotor via extensive experimental tests.

  8. Fast, accurate, and robust automatic marker detection for motion correction based on oblique kV or MV projection image pairs

    International Nuclear Information System (INIS)

    Slagmolen, Pieter; Hermans, Jeroen; Maes, Frederik; Budiharto, Tom; Haustermans, Karin; Heuvel, Frank van den

    2010-01-01

    Purpose: A robust and accurate method that allows the automatic detection of fiducial markers in MV and kV projection image pairs is proposed. The method allows to automatically correct for inter or intrafraction motion. Methods: Intratreatment MV projection images are acquired during each of five treatment beams of prostate cancer patients with four implanted fiducial markers. The projection images are first preprocessed using a series of marker enhancing filters. 2D candidate marker locations are generated for each of the filtered projection images and 3D candidate marker locations are reconstructed by pairing candidates in subsequent projection images. The correct marker positions are retrieved in 3D by the minimization of a cost function that combines 2D image intensity and 3D geometric or shape information for the entire marker configuration simultaneously. This optimization problem is solved using dynamic programming such that the globally optimal configuration for all markers is always found. Translational interfraction and intrafraction prostate motion and the required patient repositioning is assessed from the position of the centroid of the detected markers in different MV image pairs. The method was validated on a phantom using CT as ground-truth and on clinical data sets of 16 patients using manual marker annotations as ground-truth. Results: The entire setup was confirmed to be accurate to around 1 mm by the phantom measurements. The reproducibility of the manual marker selection was less than 3.5 pixels in the MV images. In patient images, markers were correctly identified in at least 99% of the cases for anterior projection images and 96% of the cases for oblique projection images. The average marker detection accuracy was 1.4±1.8 pixels in the projection images. The centroid of all four reconstructed marker positions in 3D was positioned within 2 mm of the ground-truth position in 99.73% of all cases. Detecting four markers in a pair of MV images

  9. Tailoring four-dimensional cone-beam CT acquisition settings for fiducial marker-based image guidance in radiation therapy.

    Science.gov (United States)

    Jin, Peng; van Wieringen, Niek; Hulshof, Maarten C C M; Bel, Arjan; Alderliesten, Tanja

    2018-04-01

    Use of four-dimensional cone-beam CT (4D-CBCT) and fiducial markers for image guidance during radiation therapy (RT) of mobile tumors is challenging due to the trade-off among image quality, imaging dose, and scanning time. This study aimed to investigate different 4D-CBCT acquisition settings for good visibility of fiducial markers in 4D-CBCT. Using these 4D-CBCTs, the feasibility of marker-based 4D registration for RT setup verification and manual respiration-induced motion quantification was investigated. For this, we applied a dynamic phantom with three different breathing motion amplitudes and included two patients with implanted markers. Irrespective of the motion amplitude, for a medium field of view (FOV), marker visibility was improved by reducing the imaging dose per projection and increasing the number of projection images; however, the scanning time was 4 to 8 min. For a small FOV, the total imaging dose and the scanning time were reduced (62.5% of the dose using a medium FOV, 2.5 min) without losing marker visibility. However, the body contour could be missing for a small FOV, which is not preferred in RT. The marker-based 4D setup verification was feasible for both the phantom and patient data. Moreover, manual marker motion quantification can achieve a high accuracy with a mean error of [Formula: see text].

  10. Development and experimental evaluation of an automatic marker registration system for tracking of augmented reality

    International Nuclear Information System (INIS)

    Yan, Wei-da; Yang Shou-feng; Ishii, Hirotake; Shimoda, Hiroshi; Izumi, Masanori

    2010-01-01

    In order to apply augmented reality in plant maintenance activities it is necessary to use real-time high accuracy tracking technology. One of the most efficient tracking methods is using paper-based markers and computing the relative position and orientation between a vision sensor (camera) and the markers through image processing and geometry calculations. In this method, the 3D-position of each marker is needed before tracking, but it is inefficient to measure all the markers manually. In this study, an automatic marker registration system was developed so as to measure the 3D-position of each marker automatically. The system is composed of a camera, a laser rangefinder and a motion base, which is used to control the pose of the laser rangefinder. A computer, connected to them, is used for controlling the system and for data transport. The results of the experimental evaluations show that the measurement takes about 21 seconds per marker and that the Root Mean Square Error (RMSE) of the position measurements is 3.5 mm. The feasibility evaluation of the system was conducted in Fugen nuclear plant. The results show that the system can largely reduce the preparatory workload of an AR application in a Nuclear Power Plant (NPP). (author)

  11. Simultaneous detection of transgenic DNA by surface plasmon resonance imaging with potential application to gene doping detection.

    Science.gov (United States)

    Scarano, Simona; Ermini, Maria Laura; Spiriti, Maria Michela; Mascini, Marco; Bogani, Patrizia; Minunni, Maria

    2011-08-15

    Surface plasmon resonance imaging (SPRi) was used as the transduction principle for the development of optical-based sensing for transgenes detection in human cell lines. The objective was to develop a multianalyte, label-free, and real-time approach for DNA sequences that are identified as markers of transgenosis events. The strategy exploits SPRi sensing to detect the transgenic event by targeting selected marker sequences, which are present on shuttle vector backbone used to carry out the transfection of human embryonic kidney (HEK) cell lines. Here, we identified DNA sequences belonging to the Cytomegalovirus promoter and the Enhanced Green Fluorescent Protein gene. System development is discussed in terms of probe efficiency and influence of secondary structures on biorecognition reaction on sensor; moreover, optimization of PCR samples pretreatment was carried out to allow hybridization on biosensor, together with an approach to increase SPRi signals by in situ mass enhancement. Real-time PCR was also employed as reference technique for marker sequences detection on human HEK cells. We can foresee that the developed system may have potential applications in the field of antidoping research focused on the so-called gene doping.

  12. Plane development of lateral surfaces for inspection systems

    Science.gov (United States)

    Francini, F.; Fontani, D.; Jafrancesco, D.; Mercatelli, L.; Sansoni, P.

    2006-08-01

    The problem of developing the lateral surfaces of a 3D object can arise in item inspection using automated imaging systems. In an industrial environment, these control systems typically work at high rate and they have to assure a reliable inspection of the single item. For compactness requirements it is not convenient to utilise three or four CCD cameras to control all the lateral surfaces of an object. Moreover it is impossible to mount optical components near the object if it is placed on a conveyor belt. The paper presents a system that integrates on a single CCD picture the images of both the frontal surface and the lateral surface of an object. It consists of a freeform lens mounted in front of a CCD camera with a commercial lens. The aim is to have a good magnification of the lateral surface, maintaining a low aberration level for exploiting the pictures in an image processing software. The freeform lens, made in plastics, redirects the light coming from the object to the camera lens. The final result is to obtain on the CCD: - the frontal and lateral surface images, with a selected magnification (even with two different values for the two images); - a gap between these two images, so an automatic method to analyse the images can be easily applied. A simple method to design the freeform lens is illustrated. The procedure also allows to obtain the imaging system modifying a current inspection system reducing the cost.

  13. Elimination of ghost markers during dual sensor-based infrared tracking of multiple individual reflective markers

    International Nuclear Information System (INIS)

    Stroian, G.; Falco, T.; Seuntjens, J.P.

    2004-01-01

    The accuracy of dose delivery in radiotherapy is affected by the uncertainty in tumor localization. Motion of internal anatomy due to physiological processes such as respiration may lead to significant displacements which compromise tumor coverage and generate irradiation of healthy tissue. Real-time tracking with infrared-based systems is often used for tracking thoracic motion in radiation therapy. We studied the origin of ghost markers ('crosstalk') which may appear during dual sensor-based infrared tracking of independent reflective markers. Ghost markers occur when two or more reflective markers are coplanar with each other and with the sensors of the two camera-based infrared tracking system. Analysis shows that sensors are not points but they have a finite extent and this extent determines for each marker a 'ghost volume'. If one reflective marker enters the ghost volume of another marker, ghost markers will be reported by the tracking system; if the reflective markers belong to a surface their 'ghost volume' is reduced to a 'ghost surface' (ghost zone). Appearance of ghost markers is predicted for markers taped on the torso of an anthropomorphic phantom. This study illustrates the dependence of the shape, extent, and location of the ghost zones on the shape of the anthropomorphic phantom, the angle of view of the tracking system, and the distance between the tracking system and the anthropomorphic phantom. It is concluded that the appearance of ghost markers can be avoided by positioning the markers outside the ghost zones of the other markers. However, if this is not possible and the initial marker configuration is ghost marker-free, ghost markers can be eliminated during real-time tracking by virtue of the fact that they appear in the coordinate data sequence only temporarily

  14. Comparison of optical design methods of freeform surfaces for imaging applications

    Science.gov (United States)

    Agócs, Tibor

    2015-09-01

    Optical systems based on freeform optical components offer many advantages over conventional systems in imaging applications, e.g. superior image quality, compact and lightweight designs. There are a few well established manufacturing method that can be used for the generation of freeform surfaces with low surface form error and low surface roughness, in the case of freeform mirrors e.g. diamond turning, nickel plating and post-polishing. Metrology is evolving rapidly, although developments are still needed in order to verify the manufactured surface with the necessary accuracy. Optical design methods of freeform surfaces are also lagging behind, many algorithms address non-imaging applications, but in the field of imaging (image-forming) only a few exists and works with various limitations. We compare the available techniques in freeform optical design for imaging and explore the advantages, disadvantages and boundary conditions of the different methods. We also intend to identify the most useful concepts and investigate how they can be embedded into commercially available optical design software.

  15. The Hepatic Lymphatic Vascular System: Structure, Function, Markers, and LymphangiogenesisSummary

    Directory of Open Access Journals (Sweden)

    Masatake Tanaka

    2016-11-01

    Full Text Available The lymphatic vascular system has been minimally explored in the liver despite its essential functions including maintenance of tissue fluid homeostasis. The discovery of specific markers for lymphatic endothelial cells has advanced the study of lymphatics by methods including imaging, cell isolation, and transgenic animal models and has resulted in rapid progress in lymphatic vascular research during the last decade. These studies have yielded concrete evidence that lymphatic vessel dysfunction plays an important role in the pathogenesis of many diseases. This article reviews the current knowledge of the structure, function, and markers of the hepatic lymphatic vascular system as well as factors associated with hepatic lymphangiogenesis and compares liver lymphatics with those in other tissues. Keywords: VEGF, Inflammation, Cirrhosis, Portal Hypertension

  16. Marker-controlled watershed for lymphoma segmentation in sequential CT images

    International Nuclear Information System (INIS)

    Yan Jiayong; Zhao Binsheng; Wang, Liang; Zelenetz, Andrew; Schwartz, Lawrence H.

    2006-01-01

    Segmentation of lymphoma containing lymph nodes is a difficult task because of multiple variables associated with the tumor's location, intensity distribution, and contrast to its surrounding tissues. In this paper, we present a reliable and practical marker-controlled watershed algorithm for semi-automated segmentation of lymphoma in sequential CT images. Robust determination of internal and external markers is the key to successful use of the marker-controlled watershed transform in the segmentation of lymphoma and is the focus of this work. The external marker in our algorithm is the circle enclosing the lymphoma in a single slice. The internal marker, however, is determined automatically by combining techniques including Canny edge detection, thresholding, morphological operation, and distance map estimation. To obtain tumor volume, the segmented lymphoma in the current slice needs to be propagated to the adjacent slice to help determine the external and internal markers for delineation of the lymphoma in that slice. The algorithm was applied to 29 lymphomas (size range, 9-53 mm in diameter; mean, 23 mm) in nine patients. A blinded radiologist manually delineated all lymphomas on all slices. The manual result served as the ''gold standard'' for comparison. Several quantitative methods were applied to objectively evaluate the performance of the segmentation algorithm. The algorithm received a mean overlap, overestimation, and underestimation ratios of 83.2%, 13.5%, and 5.5%, respectively. The mean average boundary distance and Hausdorff boundary distance were 0.7 and 3.7 mm. Preliminary results have shown the potential of this computer algorithm to allow reliable segmentation and quantification of lymphomas on sequential CT images

  17. A Novel Active Imaging Model to Design Visual Systems: A Case of Inspection System for Specular Surfaces

    Directory of Open Access Journals (Sweden)

    Jorge Azorin-Lopez

    2017-06-01

    Full Text Available The use of visual information is a very well known input from different kinds of sensors. However, most of the perception problems are individually modeled and tackled. It is necessary to provide a general imaging model that allows us to parametrize different input systems as well as their problems and possible solutions. In this paper, we present an active vision model considering the imaging system as a whole (including camera, lighting system, object to be perceived in order to propose solutions to automated visual systems that present problems that we perceive. As a concrete case study, we instantiate the model in a real application and still challenging problem: automated visual inspection. It is one of the most used quality control systems to detect defects on manufactured objects. However, it presents problems for specular products. We model these perception problems taking into account environmental conditions and camera parameters that allow a system to properly perceive the specific object characteristics to determine defects on surfaces. The validation of the model has been carried out using simulations providing an efficient way to perform a large set of tests (different environment conditions and camera parameters as a previous step of experimentation in real manufacturing environments, which more complex in terms of instrumentation and more expensive. Results prove the success of the model application adjusting scale, viewpoint and lighting conditions to detect structural and color defects on specular surfaces.

  18. Validation of deformable image registration algorithms on CT images of ex vivo porcine bladders with fiducial markers

    NARCIS (Netherlands)

    Wognum, S.; Heethuis, S. E.; Rosario, T.; Hoogeman, M. S.; Bel, A.

    2014-01-01

    The spatial accuracy of deformable image registration (DIR) is important in the implementation of image guided adaptive radiotherapy techniques for cancer in the pelvic region. Validation of algorithms is best performed on phantoms with fiducial markers undergoing controlled large deformations.

  19. MO-FG-303-01: FEATURED PRESENTATION and BEST IN PHYSICS (THERAPY): Automating LINAC QA: Design and Testing of An Image Acquisition and Processing System Utilizing a Combination of Radioluminescent Phosphors, Embedded X-Ray Markers and Optical Measurements

    International Nuclear Information System (INIS)

    Jenkins, C; Naczynski, D; Yu, S; Xing, L

    2015-01-01

    Purpose: The recent development of phosphors to visualize radiation beams from linear accelerators (LINAC) offers a unique opportunity for evaluating radiation fields within the context of the treatment space. The purpose of this study was to establish an automated, self-calibrating prototype system for performing quality assurance (QA) measurements. Methods: A thin layer of Gd 2 O 2 S:Tb phosphor and fiducial markers were embedded on several planar faces of a custom-designed phantom. The phantom was arbitrarily placed near iso-center on the couch of a LINAC equipped with on-board megavoltage (MV) and kilovoltage (kV) imagers. A plan consisting of several beams and integrated image acquisitions was delivered. Images of the phantom were collected throughout the delivery. Salient features, such as fiducials, crosshairs and beam edges were then extracted from these images used to calibrate the system, adjust for variations in phantom placement, and perform measurements. Beam edges were visualized by imaging the light generated by the phosphor on the phantom enabling direct comparison with the light field and laser locations. Registration of MV, kV and optical image data was performed using the embedded fiducial markers, enabling comparison of imaging center locations. Measurements specified by TG-142 were calculated and compared with those obtained from a commercially available QA system. Results: The system was able to automatically extract the location of the fiducials, lasers, light field and radiation field from the acquired images regardless of phantom positioning. It was also able to automatically identify the locations of fiducial markers on kV and MV images. All collected measurements were within TG-142 guidelines. The difference between the prototype and commercially available system were less than 0.2 mm. Conclusion: The prototype system demonstrated the capability of accurately and autonomously evaluating various TG-142 parameters independent of operator

  20. An In-Situ Root-Imaging System in the Context of Surface Detection of CO2

    Science.gov (United States)

    Apple, M. E.; Prince, J. B.; Bradley, A. R.; Zhou, X.; Lakkaraju, V. R.; Male, E. J.; Pickles, W.; Thordsen, J. J.; Dobeck, L.; Cunningham, A.; Spangler, L.

    2009-12-01

    Carbon sequestration is a valuable method of spatially confining CO2 belowground. The Zero Emissions Research Technology, (ZERT), site is an experimental facility in a former agricultural field on the Montana State University campus in Bozeman, Montana, where CO2 was experimentally released at a rate of 200kg/day in 2009 into a 100 meter underground injection well running parallel to the ground surface. This injection well, or pipe, has deliberate leaks at intervals, and CO2 travels from these leaks upward to the surface of the ground. The ZERT site is a model system designed with the purpose of testing methods of surface detection of CO2. One important aspect of surface detection is the determination of the effects of CO2 on the above and belowground portions of plants growing above sequestration fields. At ZERT, these plants consist of a pre-existing mixture of herbaceous species present at the agricultural field. Species growing at the ZERT site include several grasses, Dactylis glomerata (Orchard Grass), Poa pratensis (Kentucky Bluegrass), and Bromus japonicus (Japanese Brome); the nitrogen-fixing legumes Medicago sativa, (Alfalfa), and Lotus corniculatus, (Birdsfoot trefoil); and an abundance of Taraxacum officinale, (Dandelion). Although the aboveground parts of the plants at high CO2 are stressed, as indicated by changes in hyperspectral plant signatures, leaf fluorescence and leaf chlorophyll content, we are interested in determining whether the roots are also stressed. To do so, we are combining measurements of soil conductivity and soil moisture with root imaging. We are using an in-situ root-imaging system manufactured by CID, Inc. (Camas, WA), along with image analysis software (Image-J) to analyze morphometric parameters in the images and to determine what effects, if any, the presence of leaking and subsequently upwelling CO2 has on the phenology of root growth, growth and turnover of individual fine and coarse roots, branching patterns, and root

  1. Visibility and artifacts of gold fiducial markers used for image guided radiation therapy of pancreatic cancer on MRI

    International Nuclear Information System (INIS)

    Gurney-Champion, Oliver J.; Lens, Eelco; Horst, Astrid van der; Houweling, Antonetta C.; Tienhoven, Geertjan van; Bel, Arjan; Klaassen, Remy; Hooft, Jeanin E. van; Stoker, Jaap; Nederveen, Aart J.

    2015-01-01

    Purpose: In radiation therapy of pancreatic cancer, tumor alignment prior to each treatment fraction is improved when intratumoral gold fiducial markers (from here onwards: markers), which are visible on computed tomography (CT) and cone beam CT, are used. Visibility of these markers on magnetic resonance imaging (MRI) might improve image registration between CT and magnetic resonance (MR) images for tumor delineation purposes. However, concomitant image artifacts induced by markers are undesirable. The extent of visibility and artifact size depend on MRI-sequence parameters. The authors’ goal was to determine for various markers their potential to be visible and to generate artifacts, using measures that are independent of the MRI-sequence parameters. Methods: The authors selected ten different markers suitable for endoscopic placement in the pancreas and placed them into a phantom. The markers varied in diameter (0.28–0.6 mm), shape, and iron content (0%–0.5%). For each marker, the authors calculated T 2 ∗ -maps and ΔB 0 -maps using MRI measurements. A decrease in relaxation time T 2 ∗ can cause signal voids, associated with visibility, while a change in the magnetic field B 0 can cause signal shifts, which are associated with artifacts. These shifts inhibit accurate tumor delineation. As a measure for potential visibility, the authors used the volume of low T 2 ∗ , i.e., the volume for which T 2 ∗ differed from the background by >15 ms. As a measure for potential artifacts, the authors used the volume for which |ΔB 0 | > 9.4 × 10 −8 T (4 Hz). To test whether there is a correlation between visibility and artifact size, the authors calculated the Spearman’s correlation coefficient (R s ) between the volume of low T 2 ∗ and the volume of high |ΔB 0 |. The authors compared the maps with images obtained using a clinical MR-sequence. Finally, for the best visible marker as well as the marker that showed the smallest artifact, the authors

  2. Initial experience of using an iron-containing fiducial marker for radiotherapy of prostate cancer: Advantages in the visualization of markers in Computed Tomography and Magnetic Resonance Imaging

    Science.gov (United States)

    Tanaka, Osamu; Iida, Takayoshi; Komeda, Hisao; Tamaki, Masayoshi; Seike, Kensaku; Kato, Daiki; Yokoyama, Takamasa; Hirose, Shigeki; Kawaguchi, Daisuke

    2016-12-01

    Visualization of markers is critical for imaging modalities such as computed tomography (CT) and magnetic resonance imaging (MRI). However, the size of the marker varies according to the imaging technique. While a large-sized marker is more useful for visualization in MRI, it results in artifacts on CT and causes substantial pain on administration. In contrast, a small-sized marker reduces the artifacts on CT but hampers MRI detection. Herein, we report a new ironcontaining marker and compare its utility with that of non-iron-containing markers. Five patients underwent CT/MRI fusion-based intensity-modulated radiotherapy, and the markers were placed by urologists. A Gold Anchor™ (GA; diameter, 0.28 mm; length, 10 mm) was placed using a 22G needle on the right side of the prostate. A VISICOIL™ (VIS; diameter, 0.35 mm; length, 10 mm) was placed using a 19G needle on the left side. MRI was performed using T2*-weighted imaging. Three observers evaluated and scored the visual qualities of the acquired images. The mean score of visualization was almost identical between the GA and VIS in radiography and cone-beam CT (Novalis Tx). The artifacts in planning CT were slightly larger using the GA than using the VIS. The visualization of the marker on MRI using the GA was superior to that using the VIS. In conclusion, the visualization quality of radiography, conebeam CT, and planning CT was roughly equal between the GA and VIS. However, the GA was more strongly visualized than was the VIS on MRI due to iron containing.

  3. A Mobile System for Measuring Water Surface Velocities Using Unmanned Aerial Vehicle and Large-Scale Particle Image Velocimetry

    Science.gov (United States)

    Chen, Y. L.

    2015-12-01

    Measurement technologies for velocity of river flow are divided into intrusive and nonintrusive methods. Intrusive method requires infield operations. The measuring process of intrusive methods are time consuming, and likely to cause damages of operator and instrument. Nonintrusive methods require fewer operators and can reduce instrument damages from directly attaching to the flow. Nonintrusive measurements may use radar or image velocimetry to measure the velocities at the surface of water flow. The image velocimetry, such as large scale particle image velocimetry (LSPIV) accesses not only the point velocity but the flow velocities in an area simultaneously. Flow properties of an area hold the promise of providing spatially information of flow fields. This study attempts to construct a mobile system UAV-LSPIV by using an unmanned aerial vehicle (UAV) with LSPIV to measure flows in fields. The mobile system consists of a six-rotor UAV helicopter, a Sony nex5T camera, a gimbal, an image transfer device, a ground station and a remote control device. The activate gimbal helps maintain the camera lens orthogonal to the water surface and reduce the extent of images being distorted. The image transfer device can monitor the captured image instantly. The operator controls the UAV by remote control device through ground station and can achieve the flying data such as flying height and GPS coordinate of UAV. The mobile system was then applied to field experiments. The deviation of velocities measured by UAV-LSPIV of field experiments and handhold Acoustic Doppler Velocimeter (ADV) is under 8%. The results of the field experiments suggests that the application of UAV-LSPIV can be effectively applied to surface flow studies.

  4. Matching Images to Models: Camera Calibration for 3-D Surface Reconstruction

    Science.gov (United States)

    Morris, Robin D.; Smelyanskiy, Vadim N.; Cheeseman. Peter C.; Norvig, Peter (Technical Monitor)

    2001-01-01

    In a previous paper we described a system which recursively recovers a super-resolved three dimensional surface model from a set of images of the surface. In that paper we assumed that the camera calibration for each image was known. In this paper we solve two problems. Firstly, if an estimate of the surface is already known, the problem is to calibrate a new image relative to the existing surface model. Secondly, if no surface estimate is available, the relative camera calibration between the images in the set must be estimated. This will allow an initial surface model to be estimated. Results of both types of estimation are given.

  5. Image Reconstruction and Evaluation: Applications on Micro-Surfaces and Lenna Image Representation

    Directory of Open Access Journals (Sweden)

    Mohammad Mayyas

    2016-09-01

    Full Text Available This article develops algorithms for the characterization and the visualization of micro-scale features using a small number of sample points, with the goal of mitigating the measurement shortcomings, which are often destructive or time consuming. The popular measurement techniques that are used in imaging of micro-surfaces include the 3D stylus or interferometric profilometry and Scanning Electron Microscopy (SEM, where both could represent the micro-surface characteristics in terms of 3D dimensional topology and greyscale image, respectively. Such images could be highly dense; therefore, traditional image processing techniques might be computationally expensive. We implement the algorithms in several case studies to rapidly examine the microscopic features of micro-surface of Microelectromechanical System (MEMS, and then we validate the results using a popular greyscale image; i.e., “Lenna” image. The contributions of this research include: First, development of local and global algorithm based on modified Thin Plate Spline (TPS model to reconstruct high resolution images of the micro-surface’s topography, and its derivatives using low resolution images. Second, development of a bending energy algorithm from our modified TPS model for filtering out image defects. Finally, development of a computationally efficient technique, referred to as Windowing, which combines TPS and Linear Sequential Estimation (LSE methods, to enhance the visualization of images. The Windowing technique allows rapid image reconstruction based on the reduction of inverse problem.

  6. Interactive definition of transfer functions in volume rendering based on image markers

    International Nuclear Information System (INIS)

    Teistler, Michael; Nowinski, Wieslaw L.; Breiman, Richard S.; Liong, Sauw Ming; Ho, Liang Yoong; Shahab, Atif

    2007-01-01

    Objectives A user interface for transfer function (TF) definition in volume rendering (VR) was developed that allows the user to intuitively assign color and opacity to the original image intensities. This software may surpass solutions currently deployed in clinical practice by simplifying the use of TFs beyond predefined settings that are not always applicable. Materials and methods The TF definition is usually a cumbersome task that requires the user to manipulate graphical representations of the TF (e.g. trapezoids). A new method that allows the user to place markers at points of interest directly on CT and MRI images or orthogonal reformations was developed based on two-dimensional region growing and a few user-definable marker-related parameters. For each user defined image marker, a segment of the transfer function is computed. The resulting TF can also be applied to the slice image views. Results were judged subjectively. Results Each individualized TF can be defined interactively in a few simple steps. For every user interaction, immediate visual feedback is given. Clinicians who tested the application appreciated being able to directly work on familiar slice images to generate the desired 3D views. Conclusion Interactive TF definition can increase the actual utility of VR, help to understand the role of the TF with its variations, and increase the acceptance of VR as a clinical tool. (orig.)

  7. Daily Prostate Volume and Position Monitoring Using Implanted Gold Markers and On-Board Imaging during Radiotherapy

    Directory of Open Access Journals (Sweden)

    Linda Kašaová

    2011-01-01

    Full Text Available Purpose: This study aimed to evaluate prostate volume changes and prostate motions during radiotherapy. Methods: In 2010, twenty-five patients were treated for prostate cancer by external beam radiotherapy with implanted fiducial markers. Coordinates of three gold markers on kilovoltage images were calculated daily. Volume changes in target structure were observed through changes in intermarker distances. Differences in patient position between laser-tattoo alignment and gold marker localization were evaluated. Intrafraction motion was assessed by measuring marker displacement on kilovoltage images acquired before and after fraction delivery. Results: Prostate shrinkage was observed in 60% of patients. The average shrinkage was 7% of the prostate’s initial volume. Corrections after laser-tattoo alignment remained mostly below 1 cm. The difference between marker centroid position on the actual images and the planning images was 2 ± 1 mm on average. The extension of intrafraction movements was 7.6 ± 0.2 mm on average. Conclusions: In our retrospective study, the possibility for prostate volume changes during radiotherapy was revealed. Intrafraction movements turned out to be the limiting factor in safety margin reduction.

  8. Automated marker tracking using noisy X-ray images degraded by the treatment beam

    Energy Technology Data Exchange (ETDEWEB)

    Wisotzky, E. [Fraunhofer Institute for Production Systems and Design Technology (IPK), Berlin (Germany); German Cancer Research Center (DKFZ), Heidelberg (Germany); Fast, M.F.; Nill, S. [The Royal Marsden NHS Foundation Trust, London (United Kingdom). Joint Dept. of Physics; Oelfke, U. [The Royal Marsden NHS Foundation Trust, London (United Kingdom). Joint Dept. of Physics; German Cancer Research Center (DKFZ), Heidelberg (Germany)

    2015-09-01

    This study demonstrates the feasibility of automated marker tracking for the real-time detection of intrafractional target motion using noisy kilovoltage (kV) X-ray images degraded by the megavoltage (MV) treatment beam. The authors previously introduced the in-line imaging geometry, in which the flat-panel detector (FPD) is mounted directly underneath the treatment head of the linear accelerator. They found that the 121 kVp image quality was severely compromised by the 6 MV beam passing through the FPD at the same time. Specific MV-induced artefacts present a considerable challenge for automated marker detection algorithms. For this study, the authors developed a new imaging geometry by re-positioning the FPD and the X-ray tube. This improved the contrast-to-noise-ratio between 40% and 72% at the 1.2 mAs/image exposure setting. The increase in image quality clearly facilitates the quick and stable detection of motion with the aid of a template matching algorithm. The setup was tested with an anthropomorphic lung phantom (including an artificial lung tumour). In the tumour one or three Calypso {sup registered} beacons were embedded to achieve better contrast during MV radiation. For a single beacon, image acquisition and automated marker detection typically took around 76±6 ms. The success rate was found to be highly dependent on imaging dose and gantry angle. To eliminate possible false detections, the authors implemented a training phase prior to treatment beam irradiation and also introduced speed limits for motion between subsequent images.

  9. Automated marker tracking using noisy X-ray images degraded by the treatment beam

    International Nuclear Information System (INIS)

    Wisotzky, E.; Fast, M.F.; Nill, S.

    2015-01-01

    This study demonstrates the feasibility of automated marker tracking for the real-time detection of intrafractional target motion using noisy kilovoltage (kV) X-ray images degraded by the megavoltage (MV) treatment beam. The authors previously introduced the in-line imaging geometry, in which the flat-panel detector (FPD) is mounted directly underneath the treatment head of the linear accelerator. They found that the 121 kVp image quality was severely compromised by the 6 MV beam passing through the FPD at the same time. Specific MV-induced artefacts present a considerable challenge for automated marker detection algorithms. For this study, the authors developed a new imaging geometry by re-positioning the FPD and the X-ray tube. This improved the contrast-to-noise-ratio between 40% and 72% at the 1.2 mAs/image exposure setting. The increase in image quality clearly facilitates the quick and stable detection of motion with the aid of a template matching algorithm. The setup was tested with an anthropomorphic lung phantom (including an artificial lung tumour). In the tumour one or three Calypso registered beacons were embedded to achieve better contrast during MV radiation. For a single beacon, image acquisition and automated marker detection typically took around 76±6 ms. The success rate was found to be highly dependent on imaging dose and gantry angle. To eliminate possible false detections, the authors implemented a training phase prior to treatment beam irradiation and also introduced speed limits for motion between subsequent images.

  10. Electronic portal imaging device detection of radioopaque markers for the evaluation of prostate position during megavoltage irradiation: a clinical study

    International Nuclear Information System (INIS)

    Vigneault, Eric; Pouliot, Jean; Laverdiere, Jacques; Roy, Jean; Dorion, Marc

    1997-01-01

    Purpose: This study was designed to assess daily prostatic apex motion relative to pelvic bone structures during megavoltage irradiation. Methods and Materials: Radioopaque markers were implanted under ultrasound guidance near the prostatic apex of 11 patients with localized prostatic carcinoma. Patients were subsequently treated with a four field-box technique at a beam energy of 23 MV. During treatment, on-line images were obtained with an electronic portal imaging device (EPID). The marker was easily identified, even on unprocessed images, and the distance between the marker and a bony landmark was measured. Timelapse movies were also reviewed. After the completion of treatment, a transcrectal ultrasound examination was performed in 8 of 11 patients, to verify the position of the marker. Results: We acquired over 900 digital portal images and analyzed posterioanterior and right lateral views. The quality of portal images obtained with megavoltage irradiation was good. It was possible to evaluate pelvic bone structures even without image histogram equalization. Moreover, the radioopaque marker was easily visible on every online portal image. The review of timelapse movies showed important interfraction motion of the marker while bone structures remained stable. We measured the position of the marker for each fraction. Marker displacements up to 1.6 cm were measured between 2 consecutive days of treatment. Important marker motions were predominantly in the posteroanterior and cephalocaudal directions. In eight patients, we verified the position of the marker relative to the prostatic apex with ultrasound at the end of the treatments. The marker remained in the trapezoid zone. Intratreatment images reviewed in two cases showed no change in marker position. Our results, obtained during the treatment courses, indicate similar or larger prostate motions than previously observed in studies that used intertreatment x-ray films and CT images. Marker implantation under

  11. High-accuracy and real-time 3D positioning, tracking system for medical imaging applications based on 3D digital image correlation

    Science.gov (United States)

    Xue, Yuan; Cheng, Teng; Xu, Xiaohai; Gao, Zeren; Li, Qianqian; Liu, Xiaojing; Wang, Xing; Song, Rui; Ju, Xiangyang; Zhang, Qingchuan

    2017-01-01

    This paper presents a system for positioning markers and tracking the pose of a rigid object with 6 degrees of freedom in real-time using 3D digital image correlation, with two examples for medical imaging applications. Traditional DIC method was improved to meet the requirements of the real-time by simplifying the computations of integral pixel search. Experiments were carried out and the results indicated that the new method improved the computational efficiency by about 4-10 times in comparison with the traditional DIC method. The system was aimed for orthognathic surgery navigation in order to track the maxilla segment after LeFort I osteotomy. Experiments showed noise for the static point was at the level of 10-3 mm and the measurement accuracy was 0.009 mm. The system was demonstrated on skin surface shape evaluation of a hand for finger stretching exercises, which indicated a great potential on tracking muscle and skin movements.

  12. Image Processing Marker Augmented Reality for Design Furniture Room

    OpenAIRE

    Desy Siswanti, Sri; Titoyan, Titoyan

    2015-01-01

    AR useful for industrial applications to enhance the visual perception of the user, for example, the AR system is capable of visually new building project at a real construction site, which gives the viewer a better understanding in accordance with the existing environment. The method used by the AR is a marker detection and tracking, the method used for the detection and tracking marker is a natural feature tracking. This method detects features that are in the marker. In detecting marker ob...

  13. Investigation of synthetic aperture methods in ultrasound surface imaging using elementary surface types.

    Science.gov (United States)

    Kerr, W; Pierce, S G; Rowe, P

    2016-12-01

    Synthetic aperture imaging methods have been employed widely in recent research in non-destructive testing (NDT), but uptake has been more limited in medical ultrasound imaging. Typically offering superior focussing power over more traditional phased array methods, these techniques have been employed in NDT applications to locate and characterise small defects within large samples, but have rarely been used to image surfaces. A desire to ultimately employ ultrasonic surface imaging for bone surface geometry measurement prior to surgical intervention motivates this research, and results are presented for initial laboratory trials of a surface reconstruction technique based on global thresholding of ultrasonic 3D point cloud data. In this study, representative geometry artefacts were imaged in the laboratory using two synthetic aperture techniques; the Total Focusing Method (TFM) and the Synthetic Aperture Focusing Technique (SAFT) employing full and narrow synthetic apertures, respectively. Three high precision metallic samples of known geometries (cuboid, sphere and cylinder) which featured a range of elementary surface primitives were imaged using a 5MHz, 128 element 1D phased array employing both SAFT and TFM approaches. The array was manipulated around the samples using a precision robotic positioning system, allowing for repeatable ultrasound derived 3D surface point clouds to be created. A global thresholding technique was then developed that allowed the extraction of the surface profiles, and these were compared with the known geometry samples to provide a quantitative measure of error of 3D surface reconstruction. The mean errors achieved with optimised SAFT imaging for the cuboidal, spherical and cylindrical samples were 1.3mm, 2.9mm and 2.0mm respectively, while those for TFM imaging were 3.7mm, 3.0mm and 3.1mm, respectively. These results were contrary to expectations given the higher information content associated with the TFM images. However, it was

  14. In vivo quantification of fluorescent molecular markers in real-time by ratio Imaging for diagnostic screening and image-guided surgery

    NARCIS (Netherlands)

    Bogaards, A.; Sterenborg, H. J. C. M.; Trachtenberg, J.; Wilson, B. C.; Lilge, L.

    2007-01-01

    Future applications of "molecular diagnostic screening" and "molecular image-guided surgery" will demand images of molecular markers with high resolution and high throughput (similar to >= 30 frames/second). MRI, SPECT, PET, optical fluorescence tomography, hyper-spectral fluorescence imaging, and

  15. Evaluation of an image-based tracking workflow using a passive marker and resonant micro-coil fiducials for automatic image plane alignment in interventional MRI.

    Science.gov (United States)

    Neumann, M; Breton, E; Cuvillon, L; Pan, L; Lorenz, C H; de Mathelin, M

    2012-01-01

    In this paper, an original workflow is presented for MR image plane alignment based on tracking in real-time MR images. A test device consisting of two resonant micro-coils and a passive marker is proposed for detection using image-based algorithms. Micro-coils allow for automated initialization of the object detection in dedicated low flip angle projection images; then the passive marker is tracked in clinical real-time MR images, with alternation between two oblique orthogonal image planes along the test device axis; in case the passive marker is lost in real-time images, the workflow is reinitialized. The proposed workflow was designed to minimize dedicated acquisition time to a single dedicated acquisition in the ideal case (no reinitialization required). First experiments have shown promising results for test-device tracking precision, with a mean position error of 0.79 mm and a mean orientation error of 0.24°.

  16. Invisible marker based augmented reality system

    Science.gov (United States)

    Park, Hanhoon; Park, Jong-Il

    2005-07-01

    Augmented reality (AR) has recently gained significant attention. The previous AR techniques usually need a fiducial marker with known geometry or objects of which the structure can be easily estimated such as cube. Placing a marker in the workspace of the user can be intrusive. To overcome this limitation, we present an AR system using invisible markers which are created/drawn with an infrared (IR) fluorescent pen. Two cameras are used: an IR camera and a visible camera, which are positioned in each side of a cold mirror so that their optical centers coincide with each other. We track the invisible markers using IR camera and visualize AR in the view of visible camera. Additional algorithms are employed for the system to have a reliable performance in the cluttered background. Experimental results are given to demonstrate the viability of the proposed system. As an application of the proposed system, the invisible marker can act as a Vision-Based Identity and Geometry (VBIG) tag, which can significantly extend the functionality of RFID. The invisible tag is the same as RFID in that it is not perceivable while more powerful in that the tag information can be presented to the user by direct projection using a mobile projector or by visualizing AR on the screen of mobile PDA.

  17. Comparison of surface contour and volumetric three-dimensional imaging of the musculoskeletal system

    International Nuclear Information System (INIS)

    Guilford, W.B.; Ullrich, C.G.; Moore, T.

    1988-01-01

    Both surface contour and volumetric three-dimensional image processing from CT data can provide accurate demonstration of skeletal anatomy. While realistic, surface contour images may obscure fine detail such as nondisplaced fractures, and thin bone may disappear. Volumetric processing can provide high detail, but the transparency effect is unnatural and may yield a confusing image. Comparison of both three-dimensional modes is presented to demonstrate those findings best shown with each and to illustrate helpful techniques to improve volumetric display, such as disarticulation of unnecessary anatomy, short-angle repeating rotation (dithering), and image combination into overlay displays

  18. Combustion of gadolinium and dysprosium chelates as a cellular integrity marker in MR imaging

    International Nuclear Information System (INIS)

    Ericsson, A.; Bach-Gansmo, T.; Niklasson, F.; Hemmingsson, A.

    1995-01-01

    A combination of gadolinium (Gd) and dysprosium (Dy) chelates was investigated as a potential marker of cell-membrane integrity by means of a double-contrast effect in MR imaging. Blood samples with varying hematocrit (Hct) levels containing intact or lysed cells were used as model systems. With intact cells, the agents were assumed to be distributed solely extracellularly and the highest Hct studied (69%) was assumed to mimic the ratio of extracellular to intracellular water in tissue. The combined effect on image intensity of Gd (in a concentration corresponding to 0.2 mmol/kg b.w. in humans) and Dy (0.6 mmol/kg b.w.) applied simultaneously was a marked difference in signal intensity between samples with intact and lysed cells in both the T1- and T2-weighted spin-echo images with a corresponding increase in the contrast-to-noise ratio. This was the result of a T1 reduction caused by Gd with a negligible Dy susceptibility effect in areas with lysed cells. On the other hand, the Dy susceptibility effect (i.e. reduced apparent T2) dominated in areas with intact cells. Thus, the combination of Gd and Dy may serve as a marker of cell-membrane integrity in MR examinations. (orig.)

  19. A case study characterizing animal fecal sources in surface water using a mitochondrial DNA marker.

    Science.gov (United States)

    Bucci, John P; Shattuck, Michelle D; Aytur, Semra A; Carey, Richard; McDowell, William H

    2017-08-01

    Water quality impairment by fecal waste in coastal watersheds is a public health issue. The present study provided evidence for the use of a mitochondrial (mtDNA) marker to detect animal fecal sources in surface water. The accurate identification of fecal pollution is based on the notion that fecal microorganisms preferentially inhabit a host animal's gut environment. In contrast, mtDNA host-specific markers are inherent to eukaryotic host cells, which offers the advantage by detecting DNA from the host rather than its fecal bacteria. The present study focused on sampling water presumably from non-point sources (NPS), which can increase bacterial and nitrogen concentrations to receiving water bodies. Stream sampling sites located within the Piscataqua River Watershed (PRW), New Hampshire, USA, were sampled from a range of sites that experienced nitrogen inputs such as sewer and septic systems and suburban runoff. Three mitochondrial (mtDNA) gene marker assays (human, bovine, and canine) were tested from surface water. Nineteen sites were sampled during an 18-month period. Analyses of the combined single and multiplex assay results showed that the proportion of occurrence was highest for bovine (15.6%; n = 77) compared to canine (5.6%; n = 70) and human (5.7%; n = 107) mtDNA gene markers. For the human mtDNA marker, there was a statistically significant relationship between presence vs. absence and land use (Fisher's test p = 0.0031). This result was evident particularly for rural suburban septic, which showed the highest proportion of presence (19.2%) compared to the urban sewered (3.3%), suburban sewered (0%), and agricultural (0%) as well as forested septic (0%) sites. Although further testing across varied land use is needed, our study provides evidence for using the mtDNA marker in large watersheds.

  20. Molecular ultrasound imaging: current status and future directions

    International Nuclear Information System (INIS)

    Deshpande, N.; Needles, A.; Willmann, J.K.

    2010-01-01

    Targeted contrast-enhanced ultrasound (molecular ultrasound) is an emerging imaging strategy that combines ultrasound technology with novel molecularly-targeted ultrasound contrast agents for assessing biological processes at the molecular level. Molecular ultrasound contrast agents are nano- or micro-sized particles that are targeted to specific molecular markers by adding high-affinity binding ligands onto the surface of the particles. Following intravenous administration, these targeted ultrasound contrast agents accumulate at tissue sites overexpressing specific molecular markers, thereby enhancing the ultrasound imaging signal. High spatial and temporal resolution, real-time imaging, non-invasiveness, relatively low costs, lack of ionising irradiation and wide availability of ultrasound systems are advantages compared to other molecular imaging modalities. In this article we review current concepts and future directions of molecular ultrasound imaging, including different classes of molecular ultrasound contrast agents, ongoing technical developments of pre-clinical and clinical ultrasound systems, the potential of molecular ultrasound for imaging different diseases at the molecular level, and the translation of molecular ultrasound into the clinic.

  1. High Retention and Safety of Percutaneously Implanted Endovascular Embolization Coils as Fiducial Markers for Image-Guided Stereotactic Ablative Radiotherapy of Pulmonary Tumors

    International Nuclear Information System (INIS)

    Hong, Julian C.; Yu Yao; Rao, Aarti K.; Dieterich, Sonja; Maxim, Peter G.; Le, Quynh-Thu; Diehn, Maximilian; Sze, Daniel Y.; Kothary, Nishita; Loo, Billy W.

    2011-01-01

    Purpose: To compare the retention rates of two types of implanted fiducial markers for stereotactic ablative radiotherapy (SABR) of pulmonary tumors, smooth cylindrical gold 'seed' markers ('seeds') and platinum endovascular embolization coils ('coils'), and to compare the complication rates associated with the respective implantation procedures. Methods and Materials: We retrospectively analyzed the retention of percutaneously implanted markers in 54 consecutive patients between January 2004 and June 2009. A total of 270 markers (129 seeds, 141 coils) were implanted in or around 60 pulmonary tumors over 59 procedures. Markers were implanted using a percutaneous approach under computed tomography (CT) guidance. Postimplantation and follow-up imaging studies were analyzed to score marker retention relative to the number of markers implanted. Markers remaining near the tumor were scored as retained. Markers in a distant location (e.g., pleural space) were scored as lost. CT imaging artifacts near markers were quantified on radiation therapy planning scans. Results: Immediately after implantation, 140 of 141 coils (99.3%) were retained, compared to 110 of 129 seeds (85.3%); the difference was highly significant (p < 0.0001). Of the total number of lost markers, 45% were reported lost during implantation, but 55% were lost immediately afterwards. No additional markers were lost on longer-term follow-up. Implanted lesions were peripherally located for both seeds (mean distance, 0.33 cm from pleural surface) and coils (0.34 cm) (p = 0.96). Incidences of all pneumothorax (including asymptomatic) and pneumothorax requiring chest tube placement were lower in implantation of coils (23% and 3%, respectively) vs. seeds (54% and 29%, respectively; p = 0.02 and 0.01). The degree of CT artifact was similar between marker types. Conclusions: Retention of CT-guided percutaneously implanted coils is significantly better than that of seed markers. Furthermore, implanting coils is at

  2. External marker-based fusion of functional and morphological images

    International Nuclear Information System (INIS)

    Kremp, S.; Schaefer, A.; Alexander, C.; Kirsch, C.M.

    1999-01-01

    The fusion of image data resulting from methods oriented toward morphology like CT, MRI with functional information coming from nuclear medicine (SPECT, PET) is frequently applied to allow for a better association between functional findings and anatomical structures. A new software was developed to provide image fusion using PET, SPECT, MRI and CT data within a short processing periode for brain as well as whole body examinations in particular thorax and abdomen. The software utilizes external markers (brain) or anatomical landmarks (thorax) for correlation. The fusion requires a periode of approx. 15 min. The examples shown emphasize the high gain in diagnostic information by fusing image data of anatomical and functional methods. (orig.) [de

  3. A COMPARISON STUDY OF DIFFERENT MARKER SELECTION METHODS FOR SPECTRAL-SPATIAL CLASSIFICATION OF HYPERSPECTRAL IMAGES

    Directory of Open Access Journals (Sweden)

    D. Akbari

    2015-12-01

    Full Text Available An effective approach based on the Minimum Spanning Forest (MSF, grown from automatically selected markers using Support Vector Machines (SVM, has been proposed for spectral-spatial classification of hyperspectral images by Tarabalka et al. This paper aims at improving this approach by using image segmentation to integrate the spatial information into marker selection process. In this study, the markers are extracted from the classification maps, obtained by both SVM and segmentation algorithms, and then are used to build the MSF. The segmentation algorithms are the watershed, expectation maximization (EM and hierarchical clustering. These algorithms are used in parallel and independently to segment the image. Moreover, the pixels of each class, with the largest population in the classification map, are kept for each region of the segmentation map. Lastly, the most reliable classified pixels are chosen from among the exiting pixels as markers. Two benchmark urban hyperspectral datasets are used for evaluation: Washington DC Mall and Berlin. The results of our experiments indicate that, compared to the original MSF approach, the marker selection using segmentation algorithms leads in more accurate classification maps.

  4. A comparative study between the imaging system and the optical tracking system in proton therapy at CNAO

    CERN Document Server

    Desplanques, Maxime; Fontana, Giulia; Pella, Andrea; Riboldi, Marco; Fattori, Giovanni; Donno, Andrea; Baroni, Guido; Orecchia, Roberto

    2013-01-01

    The synergy between in-room imaging and optical tracking, in co-operation with highly accurate robotic patient handling represents a concept for patient-set-up which has been implemented at CNAO (Centro Nazionale di Adroterapia Oncologica). In-room imaging is based on a double oblique X-ray projection system; optical tracking consists of the detection of the position of spherical markers placed directly on the patient’s skin or on the immobilization devices. These markers are used as external fiducials during patient positioning and dose delivery. This study reports the results of a comparative analysis between in-room imaging and optical tracking data for patient positioning within the framework of high-precision particle therapy. Differences between the optical tracking system (OTS) and the imaging system (IS) were on average within the expected localization accuracy. On the first 633 fractions for head and neck (H&N) set-up procedures, the corrections applied by the IS, after patient positioning usin...

  5. The monocular visual imaging technology model applied in the airport surface surveillance

    Science.gov (United States)

    Qin, Zhe; Wang, Jian; Huang, Chao

    2013-08-01

    At present, the civil aviation airports use the surface surveillance radar monitoring and positioning systems to monitor the aircrafts, vehicles and the other moving objects. Surface surveillance radars can cover most of the airport scenes, but because of the terminals, covered bridges and other buildings geometry, surface surveillance radar systems inevitably have some small segment blind spots. This paper presents a monocular vision imaging technology model for airport surface surveillance, achieving the perception of scenes of moving objects such as aircrafts, vehicles and personnel location. This new model provides an important complement for airport surface surveillance, which is different from the traditional surface surveillance radar techniques. Such technique not only provides clear objects activities screen for the ATC, but also provides image recognition and positioning of moving targets in this area. Thereby it can improve the work efficiency of the airport operations and avoid the conflict between the aircrafts and vehicles. This paper first introduces the monocular visual imaging technology model applied in the airport surface surveillance and then the monocular vision measurement accuracy analysis of the model. The monocular visual imaging technology model is simple, low cost, and highly efficient. It is an advanced monitoring technique which can make up blind spot area of the surface surveillance radar monitoring and positioning systems.

  6. The Cell Surface Markers Expression in Postmenopausal Women and Relation to Obesity and Bone Status

    OpenAIRE

    Horv?thov?, Mira; Ilavsk?, Silvia; ?tef?kov?, Korn?lia; Szabov?, Michaela; Krivo??kov?, Zora; Jahnov?, Eva; Tulinsk?, Jana; Spustov?, Viera; Gajdo?, Martin

    2017-01-01

    The age-related changes and hormonal deprivation in postmenopausal women are associated with the immune response alteration. The excessive fat accumulation, local and systemic inflammation may lead to dysregulation in immune function and relevant health problems, including obesity and osteoporosis. We analyzed the expression of cell surface markers in the venous blood specimens, stained with fluorophores-conjugated monoclonal antibodies and analysed by multicolour flow cytometry. The signific...

  7. Quantification and comparison of visibility and image artifacts of a new liquid fiducial marker in a lung phantom for image-guided radiation therapy

    DEFF Research Database (Denmark)

    Rydhög, Jonas Scherman; Jølck, Rasmus Irming; Andresen, Thomas Lars

    2015-01-01

    fiducial marker, four solid fiducial markers, and one existing liquid fiducial marker. Additionally, the image artifacts produced on computer tomography (CT) and cone-beam CT (CBCT) of all fiducial markers were quantified. Results : The authors found that the new liquid fiducial marker with the highest...... concentration of the radio-opaque component had a CNR > 2.05 for 62/63 exposures, which compared favorably to the existing solid fiducial markers and to the existing liquid fiducial marker evaluated. On CT and CBCT, the new liquid fiducial marker with the highest concentration produced lower streaking index...

  8. Smart markers for watershed-based cell segmentation.

    Directory of Open Access Journals (Sweden)

    Can Fahrettin Koyuncu

    Full Text Available Automated cell imaging systems facilitate fast and reliable analysis of biological events at the cellular level. In these systems, the first step is usually cell segmentation that greatly affects the success of the subsequent system steps. On the other hand, similar to other image segmentation problems, cell segmentation is an ill-posed problem that typically necessitates the use of domain-specific knowledge to obtain successful segmentations even by human subjects. The approaches that can incorporate this knowledge into their segmentation algorithms have potential to greatly improve segmentation results. In this work, we propose a new approach for the effective segmentation of live cells from phase contrast microscopy. This approach introduces a new set of "smart markers" for a marker-controlled watershed algorithm, for which the identification of its markers is critical. The proposed approach relies on using domain-specific knowledge, in the form of visual characteristics of the cells, to define the markers. We evaluate our approach on a total of 1,954 cells. The experimental results demonstrate that this approach, which uses the proposed definition of smart markers, is quite effective in identifying better markers compared to its counterparts. This will, in turn, be effective in improving the segmentation performance of a marker-controlled watershed algorithm.

  9. Smart markers for watershed-based cell segmentation.

    Science.gov (United States)

    Koyuncu, Can Fahrettin; Arslan, Salim; Durmaz, Irem; Cetin-Atalay, Rengul; Gunduz-Demir, Cigdem

    2012-01-01

    Automated cell imaging systems facilitate fast and reliable analysis of biological events at the cellular level. In these systems, the first step is usually cell segmentation that greatly affects the success of the subsequent system steps. On the other hand, similar to other image segmentation problems, cell segmentation is an ill-posed problem that typically necessitates the use of domain-specific knowledge to obtain successful segmentations even by human subjects. The approaches that can incorporate this knowledge into their segmentation algorithms have potential to greatly improve segmentation results. In this work, we propose a new approach for the effective segmentation of live cells from phase contrast microscopy. This approach introduces a new set of "smart markers" for a marker-controlled watershed algorithm, for which the identification of its markers is critical. The proposed approach relies on using domain-specific knowledge, in the form of visual characteristics of the cells, to define the markers. We evaluate our approach on a total of 1,954 cells. The experimental results demonstrate that this approach, which uses the proposed definition of smart markers, is quite effective in identifying better markers compared to its counterparts. This will, in turn, be effective in improving the segmentation performance of a marker-controlled watershed algorithm.

  10. Surface stress mediated image force and torque on an edge dislocation

    Science.gov (United States)

    Raghavendra, R. M.; Divya, Iyer, Ganesh; Kumar, Arun; Subramaniam, Anandh

    2018-07-01

    The proximity of interfaces gives prominence to image forces experienced by dislocations. The presence of surface stress alters the traction-free boundary conditions existing on free-surfaces and hence is expected to alter the magnitude of the image force. In the current work, using a combined simulation of surface stress and an edge dislocation in a semi-infinite body, we evaluate the configurational effects on the system. We demonstrate that if the extra half-plane of the edge dislocation is parallel to the surface, the image force (glide) is not altered due to surface stress; however, the dislocation experiences a torque. The surface stress breaks the 'climb image force' symmetry, thus leading to non-equivalence between positive and negative climb. We discover an equilibrium position for the edge dislocation in the positive 'climb geometry', arising due to a competition between the interaction of the dislocation stress fields with the surface stress and the image dislocation. Torque in the climb configuration is not affected by surface stress (remains zero). Surface stress is computed using a recently developed two-scale model based on Shuttleworth's idea and image forces using a finite element model developed earlier. The effect of surface stress on the image force and torque experienced by the dislocation monopole is analysed using illustrative 3D models.

  11. Imaging Freeform Optical Systems Designed with NURBS Surfaces

    Science.gov (United States)

    2015-12-01

    reflective, anastigmat 1 Introduction The imaging freeform optical systems described here are designed using non-uniform rational basis-spline (NURBS...code, but to succeed in designing NURBS freeform optical systems an optimization code is required. The motivation for developing the optical design

  12. Fluorescence Lifetime Imaging in Stargardt Disease: Potential Marker for Disease Progression

    OpenAIRE

    Dysli Chantal; Wolf Sebastian; Hatz Katja; Zinkernagel Martin

    2016-01-01

    PURPOSE The purpose of this study was to describe autofluorescence lifetime characteristics in Stargardt disease (STGD) using fluorescence lifetime imaging ophthalmoscopy (FLIO) and to investigate potential prognostic markers for disease activity and progression. METHODS Fluorescence lifetime data of 16 patients with STGD (mean age, 40 years; range, 22-56 years) and 15 age-matched controls were acquired using a fluorescence lifetime imaging ophthalmoscope based on a Heidelberg Eng...

  13. Behavior of Lipiodol Markers During Image Guided Radiotherapy of Bladder Cancer

    International Nuclear Information System (INIS)

    Chai Xiangfei; Herk, Marcel van; Kamer, Jeroen B. van de; Remeijer, Peter; Bex, Axel; Betgen, Anja; De Reijke, Theo M.; Hulshof, Maarten C.C.M.; Pos, Floris J.; Bel, Arjan

    2010-01-01

    Purpose: To investigate the stability of a novel type of markers used in partial bladder tumor irradiation and tumor deformation as indicated by the markers. Materials and Methods: In 15 patients with solitary bladder cancer, lipiodol was injected in the bladder wall during flexible cystoscopy to identify the tumor. A planning CT scan was made, followed by daily cone-beam CT (CBCT) scans during treatment. To study the accuracy of using these markers for image guidance, uncertainties U1 and U2 were calculated, which were defined as the difference between submask registration (covering single marker) and the average of all submask registrations and the difference between the submask registration and the general mask registration (including all markers), respectively. Finally, to study tumor deformation, the relative movement of each marker pair was correlated with the relative bladder volume (RBV). Results: The analyzed patients had 2.3 marker injections on average. The lipiodol spot size was 0.72 ± 1.1 cm 3 . The intensity of spots in both CT and CBCT was significantly higher than the surrounding bladder tissue. The uncertainties U1 and U2 were comparable, and the uncertainties in left-right direction (0.14-0.19 cm) were smaller than those in cranial-caudal and anterior-posterior directions (0.19-0.32 cm). The relative marker movement of within-zone marker pairs was much smaller (and has less dependence on the RBV) than across-zones marker pairs. Conclusions: Lipiodol markers are a feasible method to track bladder tumor by using online CBCT. Tumor deformation is observed, especially for tumors that cross the defined bladder zones.

  14. Behavior of Lipiodol Markers During Image Guided Radiotherapy of Bladder Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Chai Xiangfei, E-mail: x.chai@amc.uva.n [Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands); Herk, Marcel van [Department of Radiation Oncology, The Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands); Kamer, Jeroen B. van de [Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands); Remeijer, Peter [Department of Radiation Oncology, Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands); Bex, Axel [Department of Urology, Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands); Betgen, Anja [Department of Radiation Oncology, Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands); De Reijke, Theo M [Department of Urology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands); Hulshof, Maarten C.C.M. [Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands); Pos, Floris J [Department of Radiation Oncology, Netherlands Cancer Institute, Antoni van Leeuwenhoek Hospital, Amsterdam (Netherlands); Bel, Arjan [Department of Radiation Oncology, Academic Medical Center, University of Amsterdam, Amsterdam (Netherlands)

    2010-05-01

    Purpose: To investigate the stability of a novel type of markers used in partial bladder tumor irradiation and tumor deformation as indicated by the markers. Materials and Methods: In 15 patients with solitary bladder cancer, lipiodol was injected in the bladder wall during flexible cystoscopy to identify the tumor. A planning CT scan was made, followed by daily cone-beam CT (CBCT) scans during treatment. To study the accuracy of using these markers for image guidance, uncertainties U1 and U2 were calculated, which were defined as the difference between submask registration (covering single marker) and the average of all submask registrations and the difference between the submask registration and the general mask registration (including all markers), respectively. Finally, to study tumor deformation, the relative movement of each marker pair was correlated with the relative bladder volume (RBV). Results: The analyzed patients had 2.3 marker injections on average. The lipiodol spot size was 0.72 +- 1.1 cm{sup 3}. The intensity of spots in both CT and CBCT was significantly higher than the surrounding bladder tissue. The uncertainties U1 and U2 were comparable, and the uncertainties in left-right direction (0.14-0.19 cm) were smaller than those in cranial-caudal and anterior-posterior directions (0.19-0.32 cm). The relative marker movement of within-zone marker pairs was much smaller (and has less dependence on the RBV) than across-zones marker pairs. Conclusions: Lipiodol markers are a feasible method to track bladder tumor by using online CBCT. Tumor deformation is observed, especially for tumors that cross the defined bladder zones.

  15. Detection of organ movement in cervix cancer patients using a fluoroscopic electronic portal imaging device and radiopaque markers

    International Nuclear Information System (INIS)

    Kaatee, Robert S.J.P.; Olofsen, Manouk J.J.; Verstraate, Marjolein B.J.; Quint, Sandra; Heijmen, Ben J.M.

    2002-01-01

    Purpose: To investigate the use of a fluoroscopic electronic portal imaging device (EPID) and radiopaque markers to detect internal cervix movement. Methods and Materials: For 10 patients with radiopaque markers clamped to the cervix, electronic portal images were made during external beam irradiation. Bony structures and markers in the portal images were registered with the same structures in the corresponding digitally reconstructed radiographs of the planning computed tomogram. Results: The visibility of the markers in the portal images was good, but their fixation should be improved. Generally, the correlation between bony structure displacements and marker movement was poor, the latter being substantially larger. The standard deviations describing the systematic and random bony anatomy displacements were 1.2 and 2.6 mm, 1.7 and 2.9 mm, and 1.6 and 2.7 mm in the lateral, cranial-caudal, and dorsal-ventral directions, respectively. For the marker movement those values were 3.4 and 3.4 mm, 4.3 and 5.2 mm, 3.2 and 5.2 mm, respectively. Estimated clinical target volume to planning target volume (CTV-PTV) planning margins (∼11 mm) based on the observed overall marker displacements (bony anatomy + internal cervix movement) are only marginally larger than the margins required to account for internal marker movement alone. Conclusions: With our current patient setup techniques and methods of setup verification and correction, the required CTV-PTV margins are almost fully determined by internal organ motion. Setup verification and correction using radiopaque markers might allow decreasing those margins, but technical improvements are needed

  16. Clinical application of image-guided radiotherapy, IGRT (on the Varian OBI platform); Applications cliniques de la radiotherapie guidee par l'image (RTGI)

    Energy Technology Data Exchange (ETDEWEB)

    Sorcini, B.; Tilikidis, A. [Karolinska Univ. Hospital, Dept. of Medical Physics, Stockholm (Sweden)

    2006-09-15

    Image-guided radiation therapy (IGRT) can be used to measure and correct positional errors for target and critical structures immediately prior to or during treatment delivery. Some of the most recent available methods applied for target localization are: trans-abdominal ultrasound, implanted markers with in room MV or kV X-rays, optical surface tracking systems, implantable electromagnetic markers, in room CT such as kVCT on rail, kilo-voltage or mega-voltage cone-beam CT (CBCT) and helical megavoltage CT. The verification of the accurate treatment position in conjunction with detailed anatomical information before every fraction can be essential for the outcome of the treatment. In this paper we present the on-board imager (OBI, Varian Medical Systems, Palo Alto, CA) that has been in routine clinical use at the Karolinska University Hospital since June 2004. The OBI has been used for on-line set-up correction of prostate patients using internal gold markers. Displacements of these markers can be monitored radiographically during the treatment course and the registered marker shifts act as a surrogate for prostate motion. For this purpose, on-board kV-kV seems to be an ideal system in terms of image quality. The CBCT function of OBI was installed in March 2005 at our department. It focuses on localizing tumors based on internal anatomy, not just on the conventional external marks or tattoos. The CBCT system provides the capacity for soft tissue imaging in the treatment position and real-time radiographic monitoring during treatment delivery. (authors)

  17. MR imaging of brain surface structures: Surface anatomy scanning

    International Nuclear Information System (INIS)

    Katada, K.; Koga, S.; Asahina, M.; Kanno, T.; Asahina, K.

    1987-01-01

    Preoperative evaluation of brain surface anatomy, including cortical sulci and veins, relative to cerebral and cerebellar lesions is an important subject for surgeons. Until now, no imaging modality existed that allowed direct visualization of brain surface anatomy. A new MR imaging technique (surface anatomy scanning) was developed to visualize brain surface structures. The technique uses a spin-echo pulse sequence with long repetition and echo times, thick sections and a surface coil. Cortical sulci, fissures, veins, and intracranial lesions were clearly identified with this technique. Initial clinical results indicate that surface anatomy scanning is useful for lesion localization and for detailed evaluation of cortical and subcortical lesions

  18. Reproducibility and variability of quantitative magnetic resonance imaging markers in cerebral small vessel disease

    NARCIS (Netherlands)

    De Guio, F. (François); Jouvent, E. (Eric); G.J. Biessels (Geert Jan); S.E. Black (Sandra); C. Brayne (Carol); C. Chen (Christopher); C. Cordonnier (Charlotte); H.F. de Leeuw (Frank); C. Kubisch (Christian); Doubal, F. (Fergus); Duering, M. (Marco); C. Dufouil (Carole); Duzel, E. (Emrah); F. Fazekas (Franz); V. Hachinski (Vladimir); M.K. Ikram (Kamran); J. Linn (Jennifer); P.M. Matthews (P.); B. Mazoyer (Bernard); Mok, V. (Vincent); B. Norrving (Bo); O'Brien, J.T. (John T.); Pantoni, L. (Leonardo); S. Ropele (Stefan); P.S. Sachdev (Perminder); R. Schmidt (Reinhold); S. Seshadri (Sudha); E.E. Smith (Eric); L.A. Sposato (Luciano A); B.C.M. Stephan; Swartz, R.H. (Richard H.); C. Tzourio (Christophe); M.A. van Buchem (Mark); A. van der Lugt (Aad); R.J. van Oostenbrugge (Robert); M.W. Vernooij (Meike); Viswanathan, A. (Anand); D.J. Werring (David); Wollenweber, F. (Frank); J.M. Wardlaw (J.); Chabriat, H. (Hugues)

    2016-01-01

    textabstractBrain imaging is essential for the diagnosis and characterization of cerebral small vessel disease. Several magnetic resonance imaging markers have therefore emerged, providing new information on the diagnosis, progression, and mechanisms of small vessel disease. Yet, the reproducibility

  19. Reproducibility and variability of quantitative magnetic resonance imaging markers in cerebral small vessel disease

    NARCIS (Netherlands)

    Guio, F. De; Jouvent, E.; Biessels, G.J.; Black, S.E.; Brayne, C.; Chen, C.; Cordonnier, C.; Leeuw, F.E. de; Dichgans, M.; Doubal, F.; Duering, M.; Dufouil, C.; Duzel, E.; Fazekas, F.; Hachinski, V.; Ikram, M.A.; Linn, J.; Matthews, P.M.; Mazoyer, B.; Mok, V.; Norrving, B.; O'Brien, J.T.; Pantoni, L.; Ropele, S.; Sachdev, P.; Schmidt, R.; Seshadri, S.; Smith, E.E.; Sposato, L.A.; Stephan, B.; Swartz, R.H.; Tzourio, C.; Buchem, M. van; Lugt, A. van der; Oostenbrugge, R.; Vernooij, M.W.; Viswanathan, A.; Werring, D.; Wollenweber, F.; Wardlaw, J.M.; Chabriat, H.

    2016-01-01

    Brain imaging is essential for the diagnosis and characterization of cerebral small vessel disease. Several magnetic resonance imaging markers have therefore emerged, providing new information on the diagnosis, progression, and mechanisms of small vessel disease. Yet, the reproducibility of these

  20. SU-C-204-06: Surface Imaging for the Set-Up of Proton Post-Mastectomy Chestwall Irradiation: Gated Images Vs Non Gated Images

    Energy Technology Data Exchange (ETDEWEB)

    Batin, E; Depauw, N; MacDonald, S; Lu, H [Massachusetts General Hospital, Boston, MA (United States)

    2015-06-15

    Purpose: Historically, the set-up for proton post-mastectomy chestwall irradiation at our institution started with positioning the patient using tattoos and lasers. One or more rounds of orthogonal X-rays at gantry 0° and beamline X-ray at treatment gantry angle were then taken to finalize the set-up position. As chestwall targets are shallow and superficial, surface imaging is a promising tool for set-up and needs to be investigated Methods: The orthogonal imaging was entirely replaced by AlignRT™ (ART) images. The beamline X-Ray image is kept as a confirmation, based primarily on three opaque markers placed on skin surface instead of bony anatomy. In the first phase of the process, ART gated images were used to set-up the patient and the same specific point of the breathing curve was used every day. The moves (translations and rotations) computed for each point of the breathing curve during the first five fractions were analyzed for ten patients. During a second phase of the study, ART gated images were replaced by ART non-gated images combined with real-time monitoring. In both cases, ART images were acquired just before treatment to access the patient position compare to the non-gated CT. Results: The average difference between the maximum move and the minimum move depending on the chosen breathing curve point was less than 1.7 mm for all translations and less than 0.7° for all rotations. The average position discrepancy over the course of treatment obtained by ART non gated images combined to real-time monitoring taken before treatment to the planning CT were smaller than the average position discrepancy obtained using ART gated images. The X-Ray validation images show similar results with both ART imaging process. Conclusion: The use of ART non gated images combined with real time imaging allows positioning post-mastectomy chestwall patients in less than 3 mm / 1°.

  1. SU-C-204-06: Surface Imaging for the Set-Up of Proton Post-Mastectomy Chestwall Irradiation: Gated Images Vs Non Gated Images

    International Nuclear Information System (INIS)

    Batin, E; Depauw, N; MacDonald, S; Lu, H

    2015-01-01

    Purpose: Historically, the set-up for proton post-mastectomy chestwall irradiation at our institution started with positioning the patient using tattoos and lasers. One or more rounds of orthogonal X-rays at gantry 0° and beamline X-ray at treatment gantry angle were then taken to finalize the set-up position. As chestwall targets are shallow and superficial, surface imaging is a promising tool for set-up and needs to be investigated Methods: The orthogonal imaging was entirely replaced by AlignRT™ (ART) images. The beamline X-Ray image is kept as a confirmation, based primarily on three opaque markers placed on skin surface instead of bony anatomy. In the first phase of the process, ART gated images were used to set-up the patient and the same specific point of the breathing curve was used every day. The moves (translations and rotations) computed for each point of the breathing curve during the first five fractions were analyzed for ten patients. During a second phase of the study, ART gated images were replaced by ART non-gated images combined with real-time monitoring. In both cases, ART images were acquired just before treatment to access the patient position compare to the non-gated CT. Results: The average difference between the maximum move and the minimum move depending on the chosen breathing curve point was less than 1.7 mm for all translations and less than 0.7° for all rotations. The average position discrepancy over the course of treatment obtained by ART non gated images combined to real-time monitoring taken before treatment to the planning CT were smaller than the average position discrepancy obtained using ART gated images. The X-Ray validation images show similar results with both ART imaging process. Conclusion: The use of ART non gated images combined with real time imaging allows positioning post-mastectomy chestwall patients in less than 3 mm / 1°

  2. [Stem cells: searching predisposition to cardiac commitment by surface markers expression].

    Science.gov (United States)

    Lara-Martínez, Luis A; Gutiérrez-Villegas, Ingrid; Arenas-Luna, Victor M; Hernández-Gutierrez, Salomón

    2018-01-05

    It is well-known that cardiovascular diseases are the leading cause of death worldwide, and represent an important economic burden to health systems. In an attempt to solve this problem, stem cell therapy has emerged as a therapeutic option. Within the last 20 years, a great variety of stem cells have been used in different myocardial infarction models. Up until now, the use of cardiac stem cells (CSCs) has seemed to be the best option, but the inaccessibility and scarcity of these cells make their use unreliable. Additionally, there is a high risk as they have to be obtained directly from the heart of the patient. Unlike CSCs, adult stem cells originating from bone marrow or adipose tissue, among others, appear to be an attractive option due to their easier accessibility and abundance, but particularly due to the probable existence of cardiac progenitors among their different sub-populations. In this review an analysis is made of the surface markers present in CSCs compared with other adult stem cells. This suggested the pre-existence of cells sharing specific surface markers with CSCs, a predictable immunophenotype present in some cells, although in low proportions, and with a potential of cardiac differentiation that could be similar to CSCs, thus increasing their therapeutic value. This study highlights new perspectives regarding MSCs that would enable some of these sub-populations to be differentiated at cardiac tissue level. Copyright © 2017 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  3. Fast-MICP for frameless image-guided surgery

    International Nuclear Information System (INIS)

    Lee, Jiann-Der; Huang, Chung-Hsien; Wang, Sheng-Ta; Lin, Chung-Wei; Lee, Shin-Tseng

    2010-01-01

    Purpose: In image-guided surgery (IGS) systems, image-to-physical registration is critical for reliable anatomical information mapping and spatial guidance. Conventional stereotactic frame-based or fiducial-based approaches provide accurate registration but are not patient-friendly. This study proposes a frameless cranial IGS system that uses computer vision techniques to replace the frame or fiducials with the natural features of the patient. Methods: To perform a cranial surgery with the proposed system, the facial surface of the patient is first reconstructed by stereo vision. Accuracy is ensured by capturing parallel-line patterns projected from a calibrated LCD projector. Meanwhile, another facial surface is reconstructed from preoperative computed tomography (CT) images of the patient. The proposed iterative closest point (ICP)-based algorithm [fast marker-added ICP (Fast-MICP)] is then used to register the two facial data sets, which transfers the anatomical information from the CT images to the physical space. Results: Experimental results reveal that the Fast-MICP algorithm reduces the computational cost of marker-added ICP (J.-D. Lee et al., ''A coarse-to-fine surface registration algorithm for frameless brain surgery,'' in Proceedings of International Conference of the IEEE Engineering in Medicine and Biology Society, 2007, pp. 836-839) to 10% and achieves comparable registration accuracy, which is under 3 mm target registration error (TRE). Moreover, two types of optical-based spatial digitizing devices can be integrated for further surgical navigation. Anatomical information or image-guided surgical landmarks can be projected onto the patient to obtain an immersive augmented reality environment. Conclusion: The proposed frameless IGS system with stereo vision obtains TRE of less than 3 mm. The proposed Fast-MICP registration algorithm reduces registration time by 90% without compromising accuracy.

  4. Fast-MICP for frameless image-guided surgery

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jiann-Der; Huang, Chung-Hsien; Wang, Sheng-Ta; Lin, Chung-Wei; Lee, Shin-Tseng [Department of Electrical Engineering, Chang Gung University, Tao-Yuan 333, Taiwan (China); Department of Medical Mechatronics, Chang Gung University, Tao-Yuan 333, Taiwan (China); Department of Neurosurgery and Medical Augmented Reality Research Center, Chang Gung Memorial Hospital, No. 199, Tunghwa Rd., Taipei 105, Taiwan (China)

    2010-09-15

    Purpose: In image-guided surgery (IGS) systems, image-to-physical registration is critical for reliable anatomical information mapping and spatial guidance. Conventional stereotactic frame-based or fiducial-based approaches provide accurate registration but are not patient-friendly. This study proposes a frameless cranial IGS system that uses computer vision techniques to replace the frame or fiducials with the natural features of the patient. Methods: To perform a cranial surgery with the proposed system, the facial surface of the patient is first reconstructed by stereo vision. Accuracy is ensured by capturing parallel-line patterns projected from a calibrated LCD projector. Meanwhile, another facial surface is reconstructed from preoperative computed tomography (CT) images of the patient. The proposed iterative closest point (ICP)-based algorithm [fast marker-added ICP (Fast-MICP)] is then used to register the two facial data sets, which transfers the anatomical information from the CT images to the physical space. Results: Experimental results reveal that the Fast-MICP algorithm reduces the computational cost of marker-added ICP (J.-D. Lee et al., ''A coarse-to-fine surface registration algorithm for frameless brain surgery,'' in Proceedings of International Conference of the IEEE Engineering in Medicine and Biology Society, 2007, pp. 836-839) to 10% and achieves comparable registration accuracy, which is under 3 mm target registration error (TRE). Moreover, two types of optical-based spatial digitizing devices can be integrated for further surgical navigation. Anatomical information or image-guided surgical landmarks can be projected onto the patient to obtain an immersive augmented reality environment. Conclusion: The proposed frameless IGS system with stereo vision obtains TRE of less than 3 mm. The proposed Fast-MICP registration algorithm reduces registration time by 90% without compromising accuracy.

  5. A bronchoscopic navigation system using bronchoscope center calibration for accurate registration of electromagnetic tracker and CT volume without markers

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Xiongbiao, E-mail: xiongbiao.luo@gmail.com [Robarts Research Institute, Western University, London, Ontario N6A 5K8 (Canada)

    2014-06-15

    Purpose: Various bronchoscopic navigation systems are developed for diagnosis, staging, and treatment of lung and bronchus cancers. To construct electromagnetically navigated bronchoscopy systems, registration of preoperative images and an electromagnetic tracker must be performed. This paper proposes a new marker-free registration method, which uses the centerlines of the bronchial tree and the center of a bronchoscope tip where an electromagnetic sensor is attached, to align preoperative images and electromagnetic tracker systems. Methods: The chest computed tomography (CT) volume (preoperative images) was segmented to extract the bronchial centerlines. An electromagnetic sensor was fixed at the bronchoscope tip surface. A model was designed and printed using a 3D printer to calibrate the relationship between the fixed sensor and the bronchoscope tip center. For each sensor measurement that includes sensor position and orientation information, its corresponding bronchoscope tip center position was calculated. By minimizing the distance between each bronchoscope tip center position and the bronchial centerlines, the spatial alignment of the electromagnetic tracker system and the CT volume was determined. After obtaining the spatial alignment, an electromagnetic navigation bronchoscopy system was established to real-timely track or locate a bronchoscope inside the bronchial tree during bronchoscopic examinations. Results: The electromagnetic navigation bronchoscopy system was validated on a dynamic bronchial phantom that can simulate respiratory motion with a breath rate range of 0–10 min{sup −1}. The fiducial and target registration errors of this navigation system were evaluated. The average fiducial registration error was reduced from 8.7 to 6.6 mm. The average target registration error, which indicates all tracked or navigated bronchoscope position accuracy, was much reduced from 6.8 to 4.5 mm compared to previous registration methods. Conclusions: An

  6. A bronchoscopic navigation system using bronchoscope center calibration for accurate registration of electromagnetic tracker and CT volume without markers

    International Nuclear Information System (INIS)

    Luo, Xiongbiao

    2014-01-01

    Purpose: Various bronchoscopic navigation systems are developed for diagnosis, staging, and treatment of lung and bronchus cancers. To construct electromagnetically navigated bronchoscopy systems, registration of preoperative images and an electromagnetic tracker must be performed. This paper proposes a new marker-free registration method, which uses the centerlines of the bronchial tree and the center of a bronchoscope tip where an electromagnetic sensor is attached, to align preoperative images and electromagnetic tracker systems. Methods: The chest computed tomography (CT) volume (preoperative images) was segmented to extract the bronchial centerlines. An electromagnetic sensor was fixed at the bronchoscope tip surface. A model was designed and printed using a 3D printer to calibrate the relationship between the fixed sensor and the bronchoscope tip center. For each sensor measurement that includes sensor position and orientation information, its corresponding bronchoscope tip center position was calculated. By minimizing the distance between each bronchoscope tip center position and the bronchial centerlines, the spatial alignment of the electromagnetic tracker system and the CT volume was determined. After obtaining the spatial alignment, an electromagnetic navigation bronchoscopy system was established to real-timely track or locate a bronchoscope inside the bronchial tree during bronchoscopic examinations. Results: The electromagnetic navigation bronchoscopy system was validated on a dynamic bronchial phantom that can simulate respiratory motion with a breath rate range of 0–10 min −1 . The fiducial and target registration errors of this navigation system were evaluated. The average fiducial registration error was reduced from 8.7 to 6.6 mm. The average target registration error, which indicates all tracked or navigated bronchoscope position accuracy, was much reduced from 6.8 to 4.5 mm compared to previous registration methods. Conclusions: An

  7. Development of surface enhanced Raman scattering (SERS) spectroscopy monitoring of fuel markers to prevent fraud

    Science.gov (United States)

    Wilkinson, Timothy; Clarkson, John; White, Peter C.; Meakin, Nicholas; McDonald, Ken

    2013-05-01

    Governments often tax fuel products to generate revenues to support and stimulate their economies. They also subsidize the cost of essential fuel products. Fuel taxation and subsidization practices are both subject to fraud. Oil marketing companies also suffer from fuel fraud with loss of legitimate sales and additional quality and liability issues. The use of an advanced marking system to identify and control fraud has been shown to be effective in controlling illegal activity. DeCipher has developed surface enhanced Raman scattering (SERS) spectroscopy as its lead technology for measuring markers in fuel to identify and control malpractice. SERS has many advantages that make it highly suitable for this purpose. The SERS instruments are portable and can be used to monitor fuel at any point in the supply chain. SERS shows high specificity for the marker, with no false positives. Multiple markers can also be detected in a single SERS analysis allowing, for example, specific regional monitoring of fuel. The SERS analysis from fuel is also quick, clear and decisive, with a measurement time of less than 5 minutes. We will present results highlighting our development of the use of a highly stable silver colloid as a SERS substrate to measure the markers at ppb levels. Preliminary results from the use of a solid state SERS substrate to measure fuel markers will also be presented.

  8. Implementation of Fiducial-Based Image Registration in the Cyberknife Robotic System

    International Nuclear Information System (INIS)

    Saw, Cheng B.; Chen Hungcheng; Wagner, Henry

    2008-01-01

    Fiducial-based image registration methodology as implemented in the Cyberknife system is explored. The Cyberknife is a radiosurgery system that uses image guidance technology and computer-controlled robotics to determine target positions and adjust beam directions accordingly during the dose delivery. The image guidance system consists of 2 x-ray sources mounted on the ceiling and a detection system mounted on both sides of the treatment couch. Two orthogonal live radiographs are taken prior to and during patient treatment. Fiducial markers are identified on these radiographs and compared to a library of digital reconstructed radiographs (DRRs) using the fiducial extraction software. The fiducial extraction software initially sets an intensity threshold on the live radiographs to generate white areas on black images referred to as 'blobs.' Different threshold values are being used and blobs at the same location are assumed to originate from the same object. The number of blobs is then reduced by examining each blob against a predefined set of properties such as shape and exposure levels. The remaining blobs are further reduced by examining the location of the blobs in the inferior-superior patient axis. Those blobs that have the corresponding positions are assumed to originate from the same object. The remaining blobs are used to create fiducial configurations and are compared to the reference configuration from the computed tomography (CT) image dataset for treatment planning. The best-fit configuration is considered to have the appropriate fiducial markers. The patient position is determined based on these fiducial markers. During the treatment, the radiation beam is turned off when the Cyberknife changes nodes. This allows a time window to acquire live radiographs for the determination of the patient target position and to update the robotic manipulator to change beam orientations accordingly

  9. Colour and surface fluorescence development and their relationship with Maillard reaction markers as influenced by structural changes during cornflakes production.

    Science.gov (United States)

    Farroni, Abel; Buera, María Del Pilar

    2012-12-01

    The aim of this work was to study colour and surface fluorescence development in relation to the chemical markers for the Maillard reaction at the cooking, flaking and toasting stages of cornflake production process. Colour was measured by a calibrated computer vision system. Surface fluorescence was measured on compressed samples. Aqueous extracted Maillard reaction markers (hydroxymethylfurfural, carboxymethyl-lysine, absorbance at 420nm and total fluorescence) were measured on protease hydrolyzed samples. Sample microstructure was observed by scanning electron microscopy. During cooking the colour coordinates L(∗) and b(∗) decreased and a(∗) increased. After flaking, the samples appeared lighter, while the pigment concentration, fluorescence and hydroxymethylfurfural did not change. Toasting generated bubbles in the matrix and L(∗) apparently increased, although brown pigment concentration increased. Pigment concentration did not correlate with surface colour due to the destruction or generation of interfaces. Surface and microstructure effects can be avoided by milling and compressing the samples. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Adsorbed radioactivity and radiographic imaging of surfaces of stainless steel and titanium

    Science.gov (United States)

    Jung, Haijo

    1997-11-01

    Type 304 stainless steel used for typical surface materials of spent fuel shipping casks and titanium were exposed in the spent fuel storage pool of a typical PWR power plant. Adsorption characteristics, effectiveness of decontamination by water cleaning and by electrocleaning, and swipe effectiveness on the metal surfaces were studied. A variety of environmental conditions had been manipulated to stimulate the potential 'weeping' phenomenon that often occurs with spent fuel shipping casks during transit. In a previous study, few heterogeneous effects of adsorbed contamination onto metal surfaces were observed. Radiographic images of cask surfaces were made in this study and showed clearly heterogeneous activity distributions. Acquired radiographic images were digitized and further analyzed with an image analysis computer package and compared to calibrated images by using standard sources. The measurements of activity distribution by using the radiographic image method were consistent with that using a HPGe detector. This radiographic image method was used to study the effects of electrocleaning for total and specified areas. The Modulation Transfer Function (MTF) of a film-screen system in contact with a radioactive metal surface was studied with neutron activated gold foils and showed more broad resolution properties than general diagnostic x-ray film-screen systems. Microstructure between normal areas and hot spots showed significant differences, and one hot spot appearing as a dot on the film image consisted of several small hot spots (about 10 μm in diameter). These hot spots were observed as structural defects of the metal surfaces.

  11. An accurate algorithm to match imperfectly matched images for lung tumor detection without markers.

    Science.gov (United States)

    Rozario, Timothy; Bereg, Sergey; Yan, Yulong; Chiu, Tsuicheng; Liu, Honghuan; Kearney, Vasant; Jiang, Lan; Mao, Weihua

    2015-05-08

    In order to locate lung tumors on kV projection images without internal markers, digitally reconstructed radiographs (DRRs) are created and compared with projection images. However, lung tumors always move due to respiration and their locations change on projection images while they are static on DRRs. In addition, global image intensity discrepancies exist between DRRs and projections due to their different image orientations, scattering, and noises. This adversely affects comparison accuracy. A simple but efficient comparison algorithm is reported to match imperfectly matched projection images and DRRs. The kV projection images were matched with different DRRs in two steps. Preprocessing was performed in advance to generate two sets of DRRs. The tumors were removed from the planning 3D CT for a single phase of planning 4D CT images using planning contours of tumors. DRRs of background and DRRs of tumors were generated separately for every projection angle. The first step was to match projection images with DRRs of background signals. This method divided global images into a matrix of small tiles and similarities were evaluated by calculating normalized cross-correlation (NCC) between corresponding tiles on projections and DRRs. The tile configuration (tile locations) was automatically optimized to keep the tumor within a single projection tile that had a bad matching with the corresponding DRR tile. A pixel-based linear transformation was determined by linear interpolations of tile transformation results obtained during tile matching. The background DRRs were transformed to the projection image level and subtracted from it. The resulting subtracted image now contained only the tumor. The second step was to register DRRs of tumors to the subtracted image to locate the tumor. This method was successfully applied to kV fluoro images (about 1000 images) acquired on a Vero (BrainLAB) for dynamic tumor tracking on phantom studies. Radiation opaque markers were

  12. Ultrasound to video registration using a bi-plane transrectal probe with photoacoustic markers

    Science.gov (United States)

    Cheng, Alexis; Kang, Hyun Jae; Zhang, Haichong K.; Taylor, Russell H.; Boctor, Emad M.

    2016-03-01

    Modern surgical scenarios typically provide surgeons with additional information through fusion of video and other imaging modalities. To provide this information, the tools and devices used in surgery must be registered together with interventional guidance equipment and surgical navigation systems. In this work, we focus explicitly on registering ultrasound with a stereo camera system using photoacoustic markers. Previous work has shown that photoacoustic markers can be used in this registration task to achieve target registration errors lower than the current available systems. Photoacoustic markers are defined as a set of non-collinear laser spots projected onto some surface. They can be simultaneously visualized by a stereo camera system and an ultrasound transducer because of the photoacoustic effect. In more recent work, the three-dimensional ultrasound volume was replaced by images from a single ultrasound image pose from a convex array transducer. The feasibility of this approach was demonstrated, but the accuracy was lacking due to the physical limitations of the convex array transducer. In this work, we propose the use of a bi-plane transrectal ultrasound transducer. The main advantage of using this type of transducer is that the ultrasound elements are no longer restricted to a single plane. While this development would be limited to prostate applications, liver and kidney applications are also feasible if a suitable transducer is built. This work is demonstrated in two experiments, one without photoacoustic sources and one with. The resulting target registration error for these experiments were 1.07mm±0.35mm and 1.27mm+/-0.47mm respectively, both of which are better than current available navigation systems.

  13. Integrated radiotherapy imaging system (IRIS): design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectors.

    Science.gov (United States)

    Berbeco, Ross I; Jiang, Steve B; Sharp, Gregory C; Chen, George T; Mostafavi, Hassan; Shirato, Hiroki

    2004-01-21

    The design of an integrated radiotherapy imaging system (IRIS), consisting of gantry mounted diagnostic (kV) x-ray tubes and fast read-out flat-panel amorphous-silicon detectors, has been studied. The system is meant to be capable of three main functions: radiographs for three-dimensional (3D) patient set-up, cone-beam CT and real-time tumour/marker tracking. The goal of the current study is to determine whether one source/panel pair is sufficient for real-time tumour/marker tracking and, if two are needed, the optimal position of each relative to other components and the isocentre. A single gantry-mounted source/imager pair is certainly capable of the first two of the three functions listed above and may also be useful for the third, if combined with prior knowledge of the target's trajectory. This would be necessary because only motion in two dimensions is visible with a single imager/source system. However, with previously collected information about the trajectory, the third coordinate may be derived from the other two with sufficient accuracy to facilitate tracking. This deduction of the third coordinate can only be made if the 3D tumour/marker trajectory is consistent from fraction to fraction. The feasibility of tumour tracking with one source/imager pair has been theoretically examined here using measured lung marker trajectory data for seven patients from multiple treatment fractions. The patients' selection criteria include minimum mean amplitudes of the tumour motions greater than 1 cm peak-to-peak. The marker trajectory for each patient was modelled using the first fraction data. Then for the rest of the data, marker positions were derived from the imager projections at various gantry angles and compared with the measured tumour positions. Our results show that, due to the three dimensionality and irregular trajectory characteristics of tumour motion, on a fraction-to-fraction basis, a 'monoscopic' system (single source/imager) is inadequate for

  14. Daily online bony correction is required for prostate patients without fiducial markers or soft-tissue imaging.

    Science.gov (United States)

    Johnston, M L; Vial, P; Wiltshire, K L; Bell, L J; Blome, S; Kerestes, Z; Morgan, G W; O'Driscoll, D; Shakespeare, T P; Eade, T N

    2011-09-01

    To compare online position verification strategies with offline correction protocols for patients undergoing definitive prostate radiotherapy. We analysed 50 patients with implanted fiducial markers undergoing curative prostate radiation treatment, all of whom underwent daily kilovoltage imaging using an on-board imager. For each treatment, patients were set-up initially with skin tattoos and in-room lasers. Orthogonal on-board imager images were acquired and the couch shift to match both bony anatomy and the fiducial markers recorded. The set-up error using skin tattoos and offline bone correction was compared with online bone correction. The fiducial markers were used as the reference. Data from 1923 fractions were analysed. The systematic error was ≤1 mm for all protocols. The average random error was 2-3mm for online bony correction and 3-5mm for skin tattoos or offline-bone. Online-bone showed a significant improvement compared with offline-bone in the number of patients with >5mm set-up errors for >10% (P20% (Pmarkers or daily soft-tissue imaging. Copyright © 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  15. Three dimensional imaging of surface geometry in SEM

    International Nuclear Information System (INIS)

    Slowko, W.

    1997-01-01

    A great advantage of scanning electron microscopy (SEM) is its ability of the surface topography in the way as a human eye is accustomed to see lights and shadows on macroobjects. However, SEM's can hardly display vertical dimensions of the structures. One of possible solutions is reconstruction of the surface profiles by directional detection of secondary electrons and proper signal processing. However, the surface profile still gives two dimensional information and the method should be extended to obtain fully three dimensional imaging. The extension consists in a simultaneous reconstruction of the surface profiles in two perpendicular directions (x and y) and their superposition. The solution proposed is based on a quadrupole detector system and a computer or analogue system for signal processing. Quantitative data of the surface topography can be displayed in many manners in the system of two or three co-ordinates with use of pseudo-colour for the altitude coding. (author)

  16. Fully automatic and reference-marker-free image stitching method for full-spine and full-leg imaging with computed radiography

    Science.gov (United States)

    Wang, Xiaohui; Foos, David H.; Doran, James; Rogers, Michael K.

    2004-05-01

    Full-leg and full-spine imaging with standard computed radiography (CR) systems requires several cassettes/storage phosphor screens to be placed in a staggered arrangement and exposed simultaneously to achieve an increased imaging area. A method has been developed that can automatically and accurately stitch the acquired sub-images without relying on any external reference markers. It can detect and correct the order, orientation, and overlap arrangement of the subimages for stitching. The automatic determination of the order, orientation, and overlap arrangement of the sub-images consists of (1) constructing a hypothesis list that includes all cassette/screen arrangements, (2) refining hypotheses based on a set of rules derived from imaging physics, (3) correlating each consecutive sub-image pair in each hypothesis and establishing an overall figure-of-merit, (4) selecting the hypothesis of maximum figure-of-merit. The stitching process requires the CR reader to over scan each CR screen so that the screen edges are completely visible in the acquired sub-images. The rotational displacement and vertical displacement between two consecutive sub-images are calculated by matching the orientation and location of the screen edge in the front image and its corresponding shadow in the back image. The horizontal displacement is estimated by maximizing the correlation function between the two image sections in the overlap region. Accordingly, the two images are stitched together. This process is repeated for the newly stitched composite image and the next consecutive sub-image until a full-image composite is created. The method has been evaluated in both phantom experiments and clinical studies. The standard deviation of image misregistration is below one image pixel.

  17. Calibrating AIS images using the surface as a reference

    Science.gov (United States)

    Smith, M. O.; Roberts, D. A.; Shipman, H. M.; Adams, J. B.; Willis, S. C.; Gillespie, A. R.

    1987-01-01

    A method of evaluating the initial assumptions and uncertainties of the physical connection between Airborne Imaging Spectrometer (AIS) image data and laboratory/field spectrometer data was tested. The Tuscon AIS-2 image connects to lab reference spectra by an alignment to the image spectral endmembers through a system gain and offset for each band. Images were calibrated to reflectance so as to transform the image into a measure that is independent of the solar radiant flux. This transformation also makes the image spectra directly comparable to data from lab and field spectrometers. A method was tested for calibrating AIS images using the surface as a reference. The surface heterogeneity is defined by lab/field spectral measurements. It was found that the Tuscon AIS-2 image is consistent with each of the initial hypotheses: (1) that the AIS-2 instrument calibration is nearly linear; (2) the spectral variance is caused by sub-pixel mixtures of spectrally distinct materials and shade, and (3) that sub-pixel mixtures can be treated as linear mixtures of pure endmembers. It was also found that the image can be characterized by relatively few endmembers using the AIS-2 spectra.

  18. Subcutaneous fluid collection: An imaging marker for treatment response of infectious thoracolumbar spondylodiscitis

    International Nuclear Information System (INIS)

    Kakigi, Takahide; Okada, Tomohisa; Sakai, Osamu; Iwamoto, Yoshitaka; Kubo, Soichi; Yamamoto, Akira; Togashi, Kaori

    2015-01-01

    Highlights: • No imaging marker for treatment response of spondylodiscitis (SD) has been proposed. • Volume changes of subcutaneous fluid collection (SFC) had significant correlation with changes of C-reactive protein (CRP). • SFC can be used as an imaging marker for treatment response of SD on magnetic resonance imaging (MRI). - Abstract: Purpose: To evaluate prevalence of subcutaneous fluid collection (SFC) in infectious thoracolumbar spondylodiscitis (SD) compared with control patients and to investigate correlation between volume changes of SFC and treatment response of SD. Materials and methods: This retrospective study was approved by our institutional review board. From April 2011 to March 2012, 49 patients (24 SD and 25 non-SD patients) were enrolled. Prevalence of SFC was evaluated respectively for SD and non-SD patients using magnetic resonance imaging (MRI) on the sagittal short tau inversion recovery (STIR) imaging or fat-saturated T2-weighted imaging (T2WI), and compared. In SD patients with SFC, correlation was investigated between SFC volume on the 1st MRI and initial clinical status. The same analysis was conducted also for SFC volume changes from the 1st to 2nd or last MRI. Results: SFC was found in 20 patients with SD (83.3%) and 3 non-SD patients (12%) with significant difference (p < .001). In 20 SD patients with SFC, 17 patients had follow-up MRI. For the 1st MRI, no significant correlation was found between volume of SFC and initial status of patients, including body weight, body mass index (BMI), white blood cell (WBC), and erythrocyte sedimentation rate (ESR). However, significant positive correlations were found between changes of C-reactive protein (CRP) and SFC volume from the 1st to 2nd as well as from the 1st to the last MRI (each p < .05). Conclusion: SD patients had significantly higher prevalence of SFC than non-SD patients. Volume changes of SFC had significant correlation with changes of CRP, which can be used as an imaging

  19. Subcutaneous fluid collection: An imaging marker for treatment response of infectious thoracolumbar spondylodiscitis

    Energy Technology Data Exchange (ETDEWEB)

    Kakigi, Takahide, E-mail: tkakigi@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan); Okada, Tomohisa, E-mail: tomokada@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan); Sakai, Osamu, E-mail: osamu.sakai@bmc.org [Department of Radiology, Boston Medical Center, Boston University School of Medicine, FGH Building, 3rd Floor, 820 Harrison Avenue, Boston, MA 02118 (United States); Iwamoto, Yoshitaka, E-mail: iwacame@hotmail.co.jp [Department of General Internal Medicine, Rakuwakai Otowa Hospital, 2 Otowachoinji-cho, Yamashina-ku, Kyoto 607-8062 (Japan); Kubo, Soichi, E-mail: kubo-s@mbox.kyoto-inet.or.jp [Department of Radiology, Rakuwakai Otowa Hospital, 2 Otowachoinji-cho, Yamashina-ku, Kyoto 607-8062 (Japan); Yamamoto, Akira, E-mail: yakira@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan); Togashi, Kaori, E-mail: nmdioffice@kuhp.kyoto-ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan)

    2015-07-15

    Highlights: • No imaging marker for treatment response of spondylodiscitis (SD) has been proposed. • Volume changes of subcutaneous fluid collection (SFC) had significant correlation with changes of C-reactive protein (CRP). • SFC can be used as an imaging marker for treatment response of SD on magnetic resonance imaging (MRI). - Abstract: Purpose: To evaluate prevalence of subcutaneous fluid collection (SFC) in infectious thoracolumbar spondylodiscitis (SD) compared with control patients and to investigate correlation between volume changes of SFC and treatment response of SD. Materials and methods: This retrospective study was approved by our institutional review board. From April 2011 to March 2012, 49 patients (24 SD and 25 non-SD patients) were enrolled. Prevalence of SFC was evaluated respectively for SD and non-SD patients using magnetic resonance imaging (MRI) on the sagittal short tau inversion recovery (STIR) imaging or fat-saturated T2-weighted imaging (T2WI), and compared. In SD patients with SFC, correlation was investigated between SFC volume on the 1st MRI and initial clinical status. The same analysis was conducted also for SFC volume changes from the 1st to 2nd or last MRI. Results: SFC was found in 20 patients with SD (83.3%) and 3 non-SD patients (12%) with significant difference (p < .001). In 20 SD patients with SFC, 17 patients had follow-up MRI. For the 1st MRI, no significant correlation was found between volume of SFC and initial status of patients, including body weight, body mass index (BMI), white blood cell (WBC), and erythrocyte sedimentation rate (ESR). However, significant positive correlations were found between changes of C-reactive protein (CRP) and SFC volume from the 1st to 2nd as well as from the 1st to the last MRI (each p < .05). Conclusion: SD patients had significantly higher prevalence of SFC than non-SD patients. Volume changes of SFC had significant correlation with changes of CRP, which can be used as an imaging

  20. Defect inspection in hot slab surface: multi-source CCD imaging based fuzzy-rough sets method

    Science.gov (United States)

    Zhao, Liming; Zhang, Yi; Xu, Xiaodong; Xiao, Hong; Huang, Chao

    2016-09-01

    To provide an accurate surface defects inspection method and make the automation of robust image region of interests(ROI) delineation strategy a reality in production line, a multi-source CCD imaging based fuzzy-rough sets method is proposed for hot slab surface quality assessment. The applicability of the presented method and the devised system are mainly tied to the surface quality inspection for strip, billet and slab surface etcetera. In this work we take into account the complementary advantages in two common machine vision (MV) systems(line array CCD traditional scanning imaging (LS-imaging) and area array CCD laser three-dimensional (3D) scanning imaging (AL-imaging)), and through establishing the model of fuzzy-rough sets in the detection system the seeds for relative fuzzy connectedness(RFC) delineation for ROI can placed adaptively, which introduces the upper and lower approximation sets for RIO definition, and by which the boundary region can be delineated by RFC region competitive classification mechanism. For the first time, a Multi-source CCD imaging based fuzzy-rough sets strategy is attempted for CC-slab surface defects inspection that allows an automatic way of AI algorithms and powerful ROI delineation strategies to be applied to the MV inspection field.

  1. Development of Fluorescence Spectral Imaging for Location of Uranium Deposited on Surfaces

    International Nuclear Information System (INIS)

    Monts, D.L.; Wang, G.; Su, Y.; Jang, P.R.; Waggoner, Ch.A.

    2009-01-01

    Since the 1980's, depleted uranium (DU) has been the primary material used by the US military in armor-piercing rounds. Domestic firing ranges that have been used for DU munitions training purposes are located around the country and have varying extents of contamination by other types of projectiles. A project is underway to develop a set of sensors to locate expended DU rounds and to process soil and debris to recover the material. In the environment, metallic DU readily oxidizes to form uranium compounds that contain the uranyl (UO 2 +2 ) moiety. For more than a hundred and fifty years, it has been known that when illuminated with ultraviolet (UV) light, uranyl compounds exhibit characteristic fluorescence in the visible region (450 - 650 nm). We report our efforts to develop a transportable, quantitative Fluorescence Spectral Imaging (FSI) system to locate and quantify uranyl compounds dispersed in soils and on other surfaces on domestic firing ranges; this system can also be utilized to monitor excavation of DU munitions and separation of uranyl compounds from soils. FSI images are acquired by illuminating a surface with a UV light and using a narrow band pass filter on a camera, recording an image of the resulting fluorescence. FSI images provide both spatial and spectral information. The FSI system is described and its performance characterized in the field and also by using field samples. The development and characterization of an improved transportable FSI system is presented. The applicability of this system for detection of uranium compounds deposited on surfaces for Decontaminating and Decommissioning (D and D) activities is discussed. We have successfully demonstrated in situ a first-generation, transportable Fluorescence Spectral Imaging (FSI) system for locating uranyl compounds dispersed in soils and on other surfaces of a domestic firing range. FSI images provide both spatial and spectral information. FSI images are acquired by illuminating a

  2. Parallel image-acquisition in continuous-wave electron paramagnetic resonance imaging with a surface coil array: Proof-of-concept experiments

    Science.gov (United States)

    Enomoto, Ayano; Hirata, Hiroshi

    2014-02-01

    This article describes a feasibility study of parallel image-acquisition using a two-channel surface coil array in continuous-wave electron paramagnetic resonance (CW-EPR) imaging. Parallel EPR imaging was performed by multiplexing of EPR detection in the frequency domain. The parallel acquisition system consists of two surface coil resonators and radiofrequency (RF) bridges for EPR detection. To demonstrate the feasibility of this method of parallel image-acquisition with a surface coil array, three-dimensional EPR imaging was carried out using a tube phantom. Technical issues in the multiplexing method of EPR detection were also clarified. We found that degradation in the signal-to-noise ratio due to the interference of RF carriers is a key problem to be solved.

  3. Egypt satellite images for land surface characterization

    DEFF Research Database (Denmark)

    Hasager, Charlotte Bay

    images used for mapping the vegetation cover types and other land cover types in Egypt. The mapping ranges from 1 km resolution to 30 m resolution. The aim is to provide satellite image mapping with land surface characteristics relevant for roughness mapping.......Satellite images provide information on the land surface properties. From optical remote sensing images in the blue, green, red and near-infrared part of the electromagnetic spectrum it is possible to identify a large number of surface features. The report briefly describes different satellite...

  4. Determination of the fractal dimension surface of the fracture from SEM images with assistance of the computer image quantitative analysis system

    International Nuclear Information System (INIS)

    Wawszczak, J.

    1999-01-01

    This paper presents a procedure for quantitative image analysis for determination of the fractal dimension from SEM surface images of the fracture 0H14N5CuNb steel. Investigated quenched and tempered samples of the steel after impact tests (in room and -85 o C temperatures). This method can be useful for analysing local fractal dimension of any surface parts (not oriented) of the fracture with different topography of this surface. (author)

  5. Real-time 3D internal marker tracking during arc radiotherapy by the use of combined MV-kV imaging.

    Science.gov (United States)

    Liu, W; Wiersma, R D; Mao, W; Luxton, G; Xing, L

    2008-12-21

    To minimize the adverse dosimetric effect caused by tumor motion, it is desirable to have real-time knowledge of the tumor position throughout the beam delivery process. A promising technique to realize the real-time image guided scheme in external beam radiation therapy is through the combined use of MV and onboard kV beam imaging. The success of this MV-kV triangulation approach for fixed-gantry radiation therapy has been demonstrated. With the increasing acceptance of modern arc radiotherapy in the clinics, a timely and clinically important question is whether the image guidance strategy can be extended to arc therapy to provide the urgently needed real-time tumor motion information. While conceptually feasible, there are a number of theoretical and practical issues specific to the arc delivery that need to be resolved before clinical implementation. The purpose of this work is to establish a robust procedure of system calibration for combined MV and kV imaging for internal marker tracking during arc delivery and to demonstrate the feasibility and accuracy of the technique. A commercially available LINAC equipped with an onboard kV imager and electronic portal imaging device (EPID) was used for the study. A custom built phantom with multiple ball bearings was used to calibrate the stereoscopic MV-kV imaging system to provide the transformation parameters from imaging pixels to 3D world coordinates. The accuracy of the fiducial tracking system was examined using a 4D motion phantom capable of moving in accordance with a pre-programmed trajectory. Overall, spatial accuracy of MV-kV fiducial tracking during the arc delivery process for normal adult breathing amplitude and period was found to be better than 1 mm. For fast motion, the results depended on the imaging frame rates. The RMS error ranged from approximately 0.5 mm for the normal adult breathing pattern to approximately 1.5 mm for more extreme cases with a low imaging frame rate of 3.4 Hz. In general

  6. Real-time 3D internal marker tracking during arc radiotherapy by the use of combined MV-kV imaging

    International Nuclear Information System (INIS)

    Liu, W; Wiersma, R D; Mao, W; Luxton, G; Xing, L

    2008-01-01

    To minimize the adverse dosimetric effect caused by tumor motion, it is desirable to have real-time knowledge of the tumor position throughout the beam delivery process. A promising technique to realize the real-time image guided scheme in external beam radiation therapy is through the combined use of MV and onboard kV beam imaging. The success of this MV-kV triangulation approach for fixed-gantry radiation therapy has been demonstrated. With the increasing acceptance of modern arc radiotherapy in the clinics, a timely and clinically important question is whether the image guidance strategy can be extended to arc therapy to provide the urgently needed real-time tumor motion information. While conceptually feasible, there are a number of theoretical and practical issues specific to the arc delivery that need to be resolved before clinical implementation. The purpose of this work is to establish a robust procedure of system calibration for combined MV and kV imaging for internal marker tracking during arc delivery and to demonstrate the feasibility and accuracy of the technique. A commercially available LINAC equipped with an onboard kV imager and electronic portal imaging device (EPID) was used for the study. A custom built phantom with multiple ball bearings was used to calibrate the stereoscopic MV-kV imaging system to provide the transformation parameters from imaging pixels to 3D world coordinates. The accuracy of the fiducial tracking system was examined using a 4D motion phantom capable of moving in accordance with a pre-programmed trajectory. Overall, spatial accuracy of MV-kV fiducial tracking during the arc delivery process for normal adult breathing amplitude and period was found to be better than 1 mm. For fast motion, the results depended on the imaging frame rates. The RMS error ranged from ∼0.5 mm for the normal adult breathing pattern to ∼1.5 mm for more extreme cases with a low imaging frame rate of 3.4 Hz. In general, highly accurate real

  7. Clinical application of image-guided radiotherapy, IGRT (on the Varian OBI platform)

    International Nuclear Information System (INIS)

    Sorcini, B.; Tilikidis, A.

    2006-01-01

    Image-guided radiation therapy (IGRT) can be used to measure and correct positional errors for target and critical structures immediately prior to or during treatment delivery. Some of the most recent available methods applied for target localization are: trans-abdominal ultrasound, implanted markers with in room MV or kV X-rays, optical surface tracking systems, implantable electromagnetic markers, in room CT such as kVCT on rail, kilo-voltage or mega-voltage cone-beam CT (CBCT) and helical megavoltage CT. The verification of the accurate treatment position in conjunction with detailed anatomical information before every fraction can be essential for the outcome of the treatment. In this paper we present the on-board imager (OBI, Varian Medical Systems, Palo Alto, CA) that has been in routine clinical use at the Karolinska University Hospital since June 2004. The OBI has been used for on-line set-up correction of prostate patients using internal gold markers. Displacements of these markers can be monitored radiographically during the treatment course and the registered marker shifts act as a surrogate for prostate motion. For this purpose, on-board kV-kV seems to be an ideal system in terms of image quality. The CBCT function of OBI was installed in March 2005 at our department. It focuses on localizing tumors based on internal anatomy, not just on the conventional external marks or tattoos. The CBCT system provides the capacity for soft tissue imaging in the treatment position and real-time radiographic monitoring during treatment delivery. (authors)

  8. A motion-compensated image filter for low-dose fluoroscopy in a real-time tumor-tracking radiotherapy system

    International Nuclear Information System (INIS)

    Miyamoto, Naoki; Ishikawa, Masayori; Sutherland, Kenneth

    2015-01-01

    In the real-time tumor-tracking radiotherapy system, a surrogate fiducial marker inserted in or near the tumor is detected by fluoroscopy to realize respiratory-gated radiotherapy. The imaging dose caused by fluoroscopy should be minimized. In this work, an image processing technique is proposed for tracing a moving marker in low-dose imaging. The proposed tracking technique is a combination of a motion-compensated recursive filter and template pattern matching. The proposed image filter can reduce motion artifacts resulting from the recursive process based on the determination of the region of interest for the next frame according to the current marker position in the fluoroscopic images. The effectiveness of the proposed technique and the expected clinical benefit were examined by phantom experimental studies with actual tumor trajectories generated from clinical patient data. It was demonstrated that the marker motion could be traced in low-dose imaging by applying the proposed algorithm with acceptable registration error and high pattern recognition score in all trajectories, although some trajectories were not able to be tracked with the conventional spatial filters or without image filters. The positional accuracy is expected to be kept within ±2 mm. The total computation time required to determine the marker position is a few milliseconds. The proposed image processing technique is applicable for imaging dose reduction. (author)

  9. Mobile viewer system for virtual 3D space using infrared LED point markers and camera

    Science.gov (United States)

    Sakamoto, Kunio; Taneji, Shoto

    2006-09-01

    The authors have developed a 3D workspace system using collaborative imaging devices. A stereoscopic display enables this system to project 3D information. In this paper, we describe the position detecting system for a see-through 3D viewer. A 3D display system is useful technology for virtual reality, mixed reality and augmented reality. We have researched spatial imaging and interaction system. We have ever proposed 3D displays using the slit as a parallax barrier, the lenticular screen and the holographic optical elements(HOEs) for displaying active image 1)2)3)4). The purpose of this paper is to propose the interactive system using these 3D imaging technologies. The observer can view virtual images in the real world when the user watches the screen of a see-through 3D viewer. The goal of our research is to build the display system as follows; when users see the real world through the mobile viewer, the display system gives users virtual 3D images, which is floating in the air, and the observers can touch these floating images and interact them such that kids can make play clay. The key technologies of this system are the position recognition system and the spatial imaging display. The 3D images are presented by the improved parallax barrier 3D display. Here the authors discuss the measuring method of the mobile viewer using infrared LED point markers and a camera in the 3D workspace (augmented reality world). The authors show the geometric analysis of the proposed measuring method, which is the simplest method using a single camera not the stereo camera, and the results of our viewer system.

  10. Presence of antibodies against a cell-surface protein, cross-reactive with DNA, in systemic lupus erythrematosus: a marker of the disease

    International Nuclear Information System (INIS)

    Jacob, L.; Lety, M.A.; Choquette, D.; Viard, J.P.; Jacob, F.; Louvard, D.; Bach, J.F.

    1987-01-01

    Antibodies against a cell-surface protein, cross-reactive with double-stranded DNA, were detected in the serum of 25 patients with active human systemic lupus erythematosus (SLE), defined on the basis of the revised American Rheumatism Association classification. Among these sera, two did not display anti-DNA antibodies, as shown by Farr assay, solid-phase radioimmunoassay, and Crithidia luciliae test. Five other SLE patients were consecutively studied in active and remission states. Antibodies against the protein were detected in the serum of the 5 SLE patients when they were in active phase but not in the serum of the same patients in inactive phase of the disease. The anti-protein antibodies were not found in the serum of 10 inactive SLE patients or in the sera of 10 normal human controls, 10 patients with rheumatoid arthritis, 5 patients with scleroderma, and 4 patients with primary sicca syndrome. Taken together, these results strongly suggest that antibodies against this cell-surface protein could provide a better diagnosis marker and activity index than anti-DNA antibodies in SLE

  11. An inflatable surface coil for rectal imaging

    International Nuclear Information System (INIS)

    Martin, J.F.; Hajek, P.C.; Baker, L.L.; Gylys-Morin, V.; Mattrey, R.F.

    1986-01-01

    Surface coils have become ubiquitous in MR imaging of the body because of substantial gains in signal-to-noise ratio. Unfortunately, there are some anatomic regions, such as the prostate, for which surface coils have insufficient depth sensitivity. The authors have developed an inflatable, distributed capacitance, passively decoupled surface coil which is collapsed for insertion and reinflated for imaging. Images of the prostate are dramatically improved due to proximity of the coil. Lesions in cadaver specimens were observed which were not seen with body coil imaging. Clinical trials are expected to begin in September

  12. Detection of microbial biofilms on food processing surfaces: hyperspectral fluorescence imaging study

    Science.gov (United States)

    Jun, Won; Kim, Moon S.; Chao, Kaunglin; Lefcourt, Alan M.; Roberts, Michael S.; McNaughton, James L.

    2009-05-01

    We used a portable hyperspectral fluorescence imaging system to evaluate biofilm formations on four types of food processing surface materials including stainless steel, polypropylene used for cutting boards, and household counter top materials such as formica and granite. The objective of this investigation was to determine a minimal number of spectral bands suitable to differentiate microbial biofilm formation from the four background materials typically used during food processing. Ultimately, the resultant spectral information will be used in development of handheld portable imaging devices that can be used as visual aid tools for sanitation and safety inspection (microbial contamination) of the food processing surfaces. Pathogenic E. coli O157:H7 and Salmonella cells were grown in low strength M9 minimal medium on various surfaces at 22 +/- 2 °C for 2 days for biofilm formation. Biofilm autofluorescence under UV excitation (320 to 400 nm) obtained by hyperspectral fluorescence imaging system showed broad emissions in the blue-green regions of the spectrum with emission maxima at approximately 480 nm for both E. coli O157:H7 and Salmonella biofilms. Fluorescence images at 480 nm revealed that for background materials with near-uniform fluorescence responses such as stainless steel and formica cutting board, regardless of the background intensity, biofilm formation can be distinguished. This suggested that a broad spectral band in the blue-green regions can be used for handheld imaging devices for sanitation inspection of stainless, cutting board, and formica surfaces. The non-uniform fluorescence responses of granite make distinctions between biofilm and background difficult. To further investigate potential detection of the biofilm formations on granite surfaces with multispectral approaches, principal component analysis (PCA) was performed using the hyperspectral fluorescence image data. The resultant PCA score images revealed distinct contrast between

  13. Development of a hardware-based registration system for the multimodal medical images by USB cameras

    International Nuclear Information System (INIS)

    Iwata, Michiaki; Minato, Kotaro; Watabe, Hiroshi; Koshino, Kazuhiro; Yamamoto, Akihide; Iida, Hidehiro

    2009-01-01

    There are several medical imaging scanners and each modality has different aspect for visualizing inside of human body. By combining these images, diagnostic accuracy could be improved, and therefore, several attempts for multimodal image registration have been implemented. One popular approach is to use hybrid image scanners such as positron emission tomography (PET)/CT and single photon emission computed tomography (SPECT)/CT. However, these hybrid scanners are expensive and not fully available. We developed multimodal image registration system with universal serial bus (USB) cameras, which is inexpensive and applicable to any combinations of existed conventional imaging scanners. The multiple USB cameras will determine the three dimensional positions of a patient while scanning. Using information of these positions and rigid body transformation, the acquired image is registered to the common coordinate which is shared with another scanner. For each scanner, reference marker is attached on gantry of the scanner. For observing the reference marker's position by the USB cameras, the location of the USB cameras can be arbitrary. In order to validate the system, we scanned a cardiac phantom with different positions by PET and MRI scanners. Using this system, images from PET and MRI were visually aligned, and good correlations between PET and MRI images were obtained after the registration. The results suggest this system can be inexpensively used for multimodal image registrations. (author)

  14. System and technique for retrieving depth information about a surface by projecting a composite image of modulated light patterns

    Science.gov (United States)

    Hassebrook, Laurence G. (Inventor); Lau, Daniel L. (Inventor); Guan, Chun (Inventor)

    2010-01-01

    A technique, associated system and program code, for retrieving depth information about at least one surface of an object, such as an anatomical feature. Core features include: projecting a composite image comprising a plurality of modulated structured light patterns, at the anatomical feature; capturing an image reflected from the surface; and recovering pattern information from the reflected image, for each of the modulated structured light patterns. Pattern information is preferably recovered for each modulated structured light pattern used to create the composite, by performing a demodulation of the reflected image. Reconstruction of the surface can be accomplished by using depth information from the recovered patterns to produce a depth map/mapping thereof. Each signal waveform used for the modulation of a respective structured light pattern, is distinct from each of the other signal waveforms used for the modulation of other structured light patterns of a composite image; these signal waveforms may be selected from suitable types in any combination of distinct signal waveforms, provided the waveforms used are uncorrelated with respect to each other. The depth map/mapping to be utilized in a host of applications, for example: displaying a 3-D view of the object; virtual reality user-interaction interface with a computerized device; face--or other animal feature or inanimate object--recognition and comparison techniques for security or identification purposes; and 3-D video teleconferencing/telecollaboration.

  15. The use of gold markers and electronic portal imaging for radiotherapy verification in prostate cancer patients: Sweden Ghana Medical Centre experience

    Directory of Open Access Journals (Sweden)

    George Felix Acquah

    2014-02-01

    Full Text Available The success of radiotherapy cancer treatment delivery depends on the accuracy of patient setup for each fraction. A significant problem arises from reproducing the same patient position and prostate location during treatment planning for every fraction of the treatment process. To analyze the daily movements of the prostate, gold markers are implanted in the prostate and portal images taken and manually matched with reference images to locate the prostate. Geometrical and fiducial markers are annotated onto a highly quality generated digitally reconstructed radiographs, that are compared with portal images acquired right before treatment dose delivery. A 0 and 270 degree treatment fields are used to calculate prostate shifts for all prostate cancer patients undergoing treatment at the Sweden Ghana Medical Centre, using an iViewGT portal imaging device. After aligning of the marker positions onto the reference images, the set-up deviations corrections are displayed and an on-line correction procedure applied. The measured migrations of the prostate markers are below the threshold of 3 mm for the main plans and 2 mm for the boost plans. With daily electronic portal imaging combined with gold markers, provides an objective method for verifying and correcting the position of the prostate immediately prior to radiation delivery.--------------------------------------------Cite this article as: Acquah GF. The use of gold markers and electronic portal imaging for radiotherapy verification in prostate cancer patients: Sweden Ghana Medical Centre experience. Int J Cancer Ther Oncol 2014; 2(1:020112.DOI: http://dx.doi.org/10.14319/ijcto.0201.12

  16. A Software for the Analysis of Scripted Dialogs Based on Surface Markers

    Directory of Open Access Journals (Sweden)

    Sylvain Delisle

    2003-04-01

    Full Text Available Most information systems that deal with natural language texts do not tolerate much deviation from their idealized and simplified model of language. Spoken dialog is notoriously ungrammatical however. Because the MAREDI project focuses in particular on the automatic analysis of scripted dialogs, we needed to develop a robust capacity to analyze transcribed spoken language. This paper presents the main elements of our approach, which is based on exploiting surface markers as the best route to the semantics of the conversation modelled. We highlight the foundations of our particular conversational model and give an overview of the MAREDI system. The latter consists of three key modules, which are 1 a connectionist network to recognise speech acts, 2 a robust syntactic parser, and 3 a semantic analyzer. These three modules are fully implemented in Prolog and C++ and have been packaged into an integrated software.

  17. Visibility of solid and liquid fiducial markers used for image-guided radiation therapy on optical coherence tomography: an esophageal phantom study (Conference Presentation)

    Science.gov (United States)

    Jelvehgaran, Pouya; Alderliesten, Tanja; Weda, Jelmer J. A.; de Bruin, Daniel M.; Faber, Dirk J.; Hulshof, Maarten C. C. M.; van Leeuwen, Ton G.; van Herk, Marcel B.; de Boer, Johannes F.

    2017-03-01

    Radiation therapy (RT) is used in operable and inoperable esophageal cancer patients. Endoscopic ultrasound-guided fiducial marker placement allows improved translation of the disease extent on endoscopy to computed tomography (CT) images used for RT planning and enables image-guided RT. However, microscopic tumor extent at the time of RT planning is unknown. Endoscopic optical coherence tomography (OCT) is a high-resolution (10-30µm) imaging modality with the potential for accurately determining the longitudinal disease extent. Visibility of fiducial markers on OCT is crucial for integrating OCT findings with the RT planning CT. We investigated the visibility on OCT (NinePoint Medical, Inc.) of 13 commercially available solid (Visicoil, Gold Anchor, Flexicoil, Polymark, and QLRAD) and liquid (BioXmark, Lipiodol, and Hydrogel) fiducial markers of different diameter. We designed and manufactured a set of dedicated Silicone-based esophageal phantoms to perform imaging in a controlled environment. The esophageal phantoms consist of several layers with different TiO2 concentrations to simulate the scattering properties of a typical healthy human esophagus. Markers were placed at various depths (0.5, 1.1, 2.0, and 3.0mm). OCT imaging allowed detection of all fiducial markers and phantom layers. The signal to background ratio was 6-fold higher for the solid fiducial markers than the liquid fiducial markers, yet OCT was capable of visualizing all 13 fiducial markers at all investigated depths. We conclude that RT fiducial markers can be visualized with OCT. This allows integration of OCT findings with CT for image-guided RT.

  18. Online hyperspectral imaging system for evaluating quality of agricultural products

    Science.gov (United States)

    Mo, Changyeun; Kim, Giyoung; Lim, Jongguk

    2017-06-01

    The consumption of fresh-cut agricultural produce in Korea has been growing. The browning of fresh-cut vegetables that occurs during storage and foreign substances such as worms and slugs are some of the main causes of consumers' concerns with respect to safety and hygiene. The purpose of this study is to develop an on-line system for evaluating quality of agricultural products using hyperspectral imaging technology. The online evaluation system with single visible-near infrared hyperspectral camera in the range of 400 nm to 1000 nm that can assess quality of both surfaces of agricultural products such as fresh-cut lettuce was designed. Algorithms to detect browning surface were developed for this system. The optimal wavebands for discriminating between browning and sound lettuce as well as between browning lettuce and the conveyor belt were investigated using the correlation analysis and the one-way analysis of variance method. The imaging algorithms to discriminate the browning lettuces were developed using the optimal wavebands. The ratio image (RI) algorithm of the 533 nm and 697 nm images (RI533/697) for abaxial surface lettuce and the ratio image algorithm (RI533/697) and subtraction image (SI) algorithm (SI538-697) for adaxial surface lettuce had the highest classification accuracies. The classification accuracy of browning and sound lettuce was 100.0% and above 96.0%, respectively, for the both surfaces. The overall results show that the online hyperspectral imaging system could potentially be used to assess quality of agricultural products.

  19. Exploring surface photoreaction dynamics using pixel imaging mass spectrometry (PImMS)

    Science.gov (United States)

    Kershis, Matthew D.; Wilson, Daniel P.; White, Michael G.; John, Jaya John; Nomerotski, Andrei; Brouard, Mark; Lee, Jason W. L.; Vallance, Claire; Turchetta, Renato

    2013-08-01

    A new technique for studying surface photochemistry has been developed using an ion imaging time-of-flight mass spectrometer in conjunction with a fast camera capable of multimass imaging. This technique, called pixel imaging mass spectrometry (PImMS), has been applied to the study of butanone photooxidation on TiO2(110). In agreement with previous studies of this system, it was observed that the main photooxidation pathway for butanone involves ejection of an ethyl radical into vacuum which, as confirmed by our imaging experiment, undergoes fragmentation after ionization in the mass spectrometer. This proof-of-principle experiment illustrates the usefulness and applicability of PImMS technology to problems of interest within the surface science community.

  20. Characterization of Target Volume Changes During Breast Radiotherapy Using Implanted Fiducial Markers and Portal Imaging

    International Nuclear Information System (INIS)

    Harris, Emma J.; Donovan, Ellen M.; Yarnold, John R.; Coles, Charlotte E.; Evans, Philip M.

    2009-01-01

    Purpose: To determine target volume changes by using volume and shape analysis for patients receiving radiotherapy after breast conservation surgery and to compare different methods of automatically identifying changes in target volume, position, size, and shape during radiotherapy for use in adaptive radiotherapy. Methods and Materials: Eleven patients undergoing whole breast radiotherapy had fiducial markers sutured into the excision cavity at the time of surgery. Patients underwent imaging using computed tomography (for planning and at the end of treatment) and during treatment by using portal imaging. A marker volume (MV) was defined by using the measured marker positions. Changes in both individual marker positions and MVs were identified manually and using six automated similarity indices. Comparison of the two types of analysis (manual and automated) was undertaken to establish whether similarity indices can be used to automatically detect changes in target volumes. Results: Manual analysis showed that 3 patients had significant MV reduction. This analysis also showed significant changes between planning computed tomography and the start of treatment for 9 patients, including single and multiple marker movement, deformation (shape change), and rotation. Four of the six similarity indices were shown to be sensitive to the observed changes. Conclusions: Significant changes in size, shape, and position occur to the fiducial marker-defined volume. Four similarity indices can be used to identify these changes, and a protocol for their use in adaptive radiotherapy is suggested

  1. Wear-less floating contact imaging of polymer surfaces

    International Nuclear Information System (INIS)

    Knoll, A; Rothuizen, H; Gotsmann, B; Duerig, U

    2010-01-01

    An atomic force microscopy (AFM) technique is described combining two operating modes that previously were mutually exclusive: gentle imaging of delicate surfaces requiring slow dynamic AFM techniques, and passive feedback contact mode AFM enabling ultra-fast imaging. A high-frequency force modulation is used to excite resonant modes in the MHz range of a highly compliant cantilever force sensor with a spring constant of 0.1 N m -1 . The high-order mode acts as a stiff system for modulating the tip-sample distance and a vibration amplitude of 1 nm is sufficient to overcome the adhesion interaction. The soft cantilever provides a force-controlled support for the vibrating tip, enabling high-speed intermittent contact force microscopy without feedback control of the cantilever bending. Using this technique, we were able to image delicate polymer surfaces and to completely suppress the formation of the ripple wear patterns that are commonly observed in contact AFM.

  2. Augmented reality-guided neurosurgery: accuracy and intraoperative application of an image projection technique.

    Science.gov (United States)

    Besharati Tabrizi, Leila; Mahvash, Mehran

    2015-07-01

    An augmented reality system has been developed for image-guided neurosurgery to project images with regions of interest onto the patient's head, skull, or brain surface in real time. The aim of this study was to evaluate system accuracy and to perform the first intraoperative application. Images of segmented brain tumors in different localizations and sizes were created in 10 cases and were projected to a head phantom using a video projector. Registration was performed using 5 fiducial markers. After each registration, the distance of the 5 fiducial markers from the visualized tumor borders was measured on the virtual image and on the phantom. The difference was considered a projection error. Moreover, the image projection technique was intraoperatively applied in 5 patients and was compared with a standard navigation system. Augmented reality visualization of the tumors succeeded in all cases. The mean time for registration was 3.8 minutes (range 2-7 minutes). The mean projection error was 0.8 ± 0.25 mm. There were no significant differences in accuracy according to the localization and size of the tumor. Clinical feasibility and reliability of the augmented reality system could be proved intraoperatively in 5 patients (projection error 1.2 ± 0.54 mm). The augmented reality system is accurate and reliable for the intraoperative projection of images to the head, skull, and brain surface. The ergonomic advantage of this technique improves the planning of neurosurgical procedures and enables the surgeon to use direct visualization for image-guided neurosurgery.

  3. A monthly quality assurance procedure for 3D surface imaging.

    Science.gov (United States)

    Wooten, H Omar; Klein, Eric E; Gokhroo, Garima; Santanam, Lakshmi

    2010-12-21

    A procedure for periodic quality assurance of a video surface imaging system is introduced. AlignRT is a video camera-based patient localization system that captures and compares images of a patient's topography to a DICOM-formatted external contour, then calculates shifts required to accurately reposition the patient. This technical note describes the tools and methods implemented in our department to verify correct and accurate operation of the AlignRT hardware and software components. The procedure described is performed monthly and complements a daily calibration of the system.

  4. Iterative h-minima-based marker-controlled watershed for cell nucleus segmentation.

    Science.gov (United States)

    Koyuncu, Can Fahrettin; Akhan, Ece; Ersahin, Tulin; Cetin-Atalay, Rengul; Gunduz-Demir, Cigdem

    2016-04-01

    Automated microscopy imaging systems facilitate high-throughput screening in molecular cellular biology research. The first step of these systems is cell nucleus segmentation, which has a great impact on the success of the overall system. The marker-controlled watershed is a technique commonly used by the previous studies for nucleus segmentation. These studies define their markers finding regional minima on the intensity/gradient and/or distance transform maps. They typically use the h-minima transform beforehand to suppress noise on these maps. The selection of the h value is critical; unnecessarily small values do not sufficiently suppress the noise, resulting in false and oversegmented markers, and unnecessarily large ones suppress too many pixels, causing missing and undersegmented markers. Because cell nuclei show different characteristics within an image, the same h value may not work to define correct markers for all the nuclei. To address this issue, in this work, we propose a new watershed algorithm that iteratively identifies its markers, considering a set of different h values. In each iteration, the proposed algorithm defines a set of candidates using a particular h value and selects the markers from those candidates provided that they fulfill the size requirement. Working with widefield fluorescence microscopy images, our experiments reveal that the use of multiple h values in our iterative algorithm leads to better segmentation results, compared to its counterparts. © 2016 International Society for Advancement of Cytometry. © 2016 International Society for Advancement of Cytometry.

  5. Visibility of an iron-containing fiducial marker in magnetic resonance imaging for high-precision external beam prostate radiotherapy.

    Science.gov (United States)

    Tanaka, Osamu; Komeda, Hisao; Hirose, Shigeki; Taniguchi, Takuya; Ono, Kousei; Matsuo, Masayuki

    2017-11-29

    Visualization of fiducial gold markers is critical for registration on computed tomography (CT) and magnetic resonance imaging (MRI) for imaging-guided radiotherapy. Although larger markers provide better visualization on MRI, they tend to generate artifacts on CT. MRI is strongly influenced by the presence of metals, such as iron, in the body. Here we compared efficacies of a 0.5% iron-containing gold marker (GM) and a traditional non-iron-containing marker. Twenty-seven patients underwent CT/MRI fusion-based intensity-modulated radiotherapy. Markers were placed by urologists under local anesthesia. Gold Anchor (GA; diameter: 0.28 mm; length: 10 mm), an iron-containing marker, was placed on the right side of the prostate using a 22-G needle and VISICOIL (VIS; diameter: 0.35 mm; length: 10 mm), a non-iron-containing marker, was placed on the left side using a 19-G needle. T2*-weighted images MRI sequences were obtained. Two radiation oncologists and a radiation technologist evaluated and assigned scores for visual quality on a five-point scale (1, poor; 5, best visibility). Artifact generation on CT was slightly greater with GA than with VIS. The mean marker visualization scores on MRI of all three observers were significantly superior for GA than for VIS (3.5 vs 3.2, 3.9 vs 3.2, and 4.0 vs 2.9). The actual size of the spherical GA was about 2 mm in diameter, but the signal void on MRI was approximately 5 mm. Although both markers were well visualized and can be recommended clinically, the results suggest that GA has some subtle advantages for quantitative visualization that could prove useful in certain situations of stereotactic body radiotherapy and intensity-modulated radiotherapy. © 2017 John Wiley & Sons Australia, Ltd.

  6. Physical-mechanical image of the cell surface on the base of AFM data in contact mode

    Science.gov (United States)

    Starodubtseva, M. N.; Starodubtsev, I. E.; Yegorenkov, N. I.; Kuzhel, N. S.; Konstantinova, E. E.; Chizhik, S. A.

    2017-10-01

    Physical and mechanical properties of the cell surface are well-known markers of a cell state. The complex of the parameters characterizing the cell surface properties, such as the elastic modulus (E), the parameters of adhesive (Fa), and friction (Ff) forces can be measured using atomic force microscope (AFM) in a contact mode and form namely the physical-mechanical image of the cell surface that is a fundamental element of the cell mechanical phenotype. The paper aims at forming the physical-mechanical images of the surface of two types of glutaraldehyde-fixed cancerous cells (human epithelial cells of larynx carcinoma, HEp-2c cells, and breast adenocarcinoma, MCF-7 cells) based on the data obtained by AFM in air and revealing the basic difference between them. The average values of friction, elastic and adhesive forces, and the roughness of lateral force maps, as well as dependence of the fractal dimension of lateral force maps on Z-scale factor have been studied. We have revealed that the response of microscale areas of the HEp-2c cell surface having numerous microvilli to external mechanical forces is less expressed and more homogeneous in comparison with the response of MCF-7 cell surface.

  7. Imaging method of brain surface anatomy structures using conventional T2-weighted MR images

    International Nuclear Information System (INIS)

    Hatanaka, Masahiko; Machida, Yoshio; Yoshida, Tadatoki; Katada, Kazuhiro.

    1992-01-01

    As a non-invasive technique for visualizing the brain surface structure by MRI, surface anatomy scanning (SAS) and the multislice SAS methods have been developed. Both techniques require additional MRI scanning to obtain images for the brain surface. In this paper, we report an alternative method to obtain the brain surface image using conventional T2-weighted multislice images without any additional scanning. The power calculation of the image pixel values, which is incorporated in the routine processing, has been applied in order to enhance the cerebrospinal fluid (CSF) contrast. We think that this method is one of practical approaches for imaging the surface anatomy of the brain. (author)

  8. Imaging near-surface heterogeneities by natural migration of surface waves

    KAUST Repository

    Liu, Zhaolun; AlTheyab, Abdullah; Hanafy, Sherif M.; Schuster, Gerard T.

    2016-01-01

    We demonstrate that near-surface heterogeneities can be imaged by natural migration of backscattered surface waves in common shot gathers. No velocity model is required because the data are migrated onto surface points with the virtual Green

  9. Improvement of the image quality of a high-temperature vision system

    International Nuclear Information System (INIS)

    Fabijańska, Anna; Sankowski, Dominik

    2009-01-01

    In this paper, the issues of controlling and improving the image quality of a high-temperature vision system are considered. The image quality improvement is needed to measure the surface properties of metals and alloys. Two levels of image quality control and improvement are defined in the system. The first level in hardware aims at adjusting the system configuration to obtain the highest contrast and weakest aura images. When optimal configuration is obtained, the second level in software is applied. In this stage, image enhancement algorithms are applied which have been developed with consideration of distortions arising from the vision system components and specificity of images acquired during the measurement process. The developed algorithms have been applied in the vision system to images. The influence on the accuracy of wetting angles and surface tension determination are considered

  10. FPGA based image processing for optical surface inspection with real time constraints

    Science.gov (United States)

    Hasani, Ylber; Bodenstorfer, Ernst; Brodersen, Jörg; Mayer, Konrad J.

    2015-02-01

    Today, high-quality printing products like banknotes, stamps, or vouchers, are automatically checked by optical surface inspection systems. In a typical optical surface inspection system, several digital cameras acquire the printing products with fine resolution from different viewing angles and at multiple wavelengths of the visible and also near infrared spectrum of light. The cameras deliver data streams with a huge amount of image data that have to be processed by an image processing system in real time. Due to the printing industry's demand for higher throughput together with the necessity to check finer details of the print and its security features, the data rates to be processed tend to explode. In this contribution, a solution is proposed, where the image processing load is distributed between FPGAs and digital signal processors (DSPs) in such a way that the strengths of both technologies can be exploited. The focus lies upon the implementation of image processing algorithms in an FPGA and its advantages. In the presented application, FPGAbased image-preprocessing enables real-time implementation of an optical color surface inspection system with a spatial resolution of 100 μm and for object speeds over 10 m/s. For the implementation of image processing algorithms in the FPGA, pipeline parallelism with clock frequencies up to 150 MHz together with spatial parallelism based on multiple instantiations of modules for parallel processing of multiple data streams are exploited for the processing of image data of two cameras and three color channels. Due to their flexibility and their fast response times, it is shown that FPGAs are ideally suited for realizing a configurable all-digital PLL for the processing of camera line-trigger signals with frequencies about 100 kHz, using pure synchronous digital circuit design.

  11. Direct Imaging of Stellar Surfaces: Results from the Stellar Imager (SI) Vision Mission Study

    Science.gov (United States)

    Carpenter, Kenneth; Schrijver, Carolus; Karovska, Margarita

    2006-01-01

    The Stellar Imager (SI) is a UV-Optical, Space-Based Interferometer designed to enable 0.1 milli-arcsecond (mas) spectral imaging of stellar surfaces and stellar interiors (via asteroseismology) and of the Universe in general. SI is identified as a "Flagship and Landmark Discovery Mission'' in the 2005 Sun Solar System Connection (SSSC) Roadmap and as a candidate for a "Pathways to Life Observatory'' in the Exploration of the Universe Division (EUD) Roadmap (May, 2005). The ultra-sharp images of the Stellar Imager will revolutionize our view of many dynamic astrophysical processes: The 0.1 mas resolution of this deep-space telescope will transform point sources into extended sources, and snapshots into evolving views. SI's science focuses on the role of magnetism in the Universe, particularly on magnetic activity on the surfaces of stars like the Sun. SI's prime goal is to enable long-term forecasting of solar activity and the space weather that it drives in support of the Living With a Star program in the Exploration Era. SI will also revolutionize our understanding of the formation of planetary systems, of the habitability and climatology of distant planets, and of many magneto-hydrodynamically controlled processes in the Universe. In this paper we will discuss the results of the SI Vision Mission Study, elaborating on the science goals of the SI Mission and a mission architecture that could meet those goals.

  12. Magnetic Resonance Imaging Features as Surrogate Markers of X-Linked Hypophosphatemic Rickets Activity.

    Science.gov (United States)

    Lempicki, Marta; Rothenbuhler, Anya; Merzoug, Valérie; Franchi-Abella, Stéphanie; Chaussain, Catherine; Adamsbaum, Catherine; Linglart, Agnès

    2017-01-01

    X-linked hypophosphatemic rickets (XLH) is the most common form of inheritable rickets. Rickets treatment is monitored by assessing alkaline phosphatase (ALP) levels, clinical features, and radiographs. Our objectives were to describe the magnetic resonance imaging (MRI) features of XLH and to assess correlations with disease activity. Twenty-seven XLH patients (median age 9.2 years) were included in this prospective single-center observational study. XLH activity was assessed using height, leg bowing, dental abscess history, and serum ALP levels. We looked for correlations between MRI features and markers of disease activity. On MRI, the median maximum width of the physis was 5.6 mm (range 4.8-7.8; normal 1.5 mm in all of the patients. The appearance of the zone of provisional calcification was abnormal on 21 MRI images (78%), Harris lines were present on 24 (89%), and bone marrow signal abnormalities were present on 16 (59%). ALP levels correlated with the maximum physeal widening and with the transverse extent of the widening. MRI of the knee provides precise rickets patterns that are correlated with ALP, an established biochemical marker of the disease, avoiding X-ray exposure and providing surrogate quantitative markers of disease activity. © 2017 S. Karger AG, Basel.

  13. Imaging near-surface heterogeneities by natural migration of backscattered surface waves

    KAUST Repository

    AlTheyab, Abdullah

    2016-02-01

    We present a migration method that does not require a velocity model to migrate backscattered surface waves to their projected locations on the surface. This migration method, denoted as natural migration, uses recorded Green\\'s functions along the surface instead of simulated Green\\'s functions. The key assumptions are that the scattering bodies are within the depth interrogated by the surface waves, and the Green\\'s functions are recorded with dense receiver sampling along the free surface. This natural migration takes into account all orders of multiples, mode conversions and non-linear effects of surface waves in the data. The natural imaging formulae are derived for both active source and ambient-noise data, and computer simulations show that natural migration can effectively image near-surface heterogeneities with typical ambient-noise sources and geophone distributions.

  14. Analysis of image plane's Illumination in Image-forming System

    International Nuclear Information System (INIS)

    Duan Lihua; Zeng Yan'an; Zhang Nanyangsheng; Wang Zhiguo; Yin Shiliang

    2011-01-01

    In the detection of optical radiation, the detecting accuracy is affected by optic power distribution of the detector's surface to a large extent. In addition, in the image-forming system, the quality of the image is greatly determined by the uniformity of the image's illumination distribution. However, in the practical optical system, affected by the factors such as field of view, false light and off axis and so on, the distribution of the image's illumination tends to be non uniform, so it is necessary to discuss the image plane's illumination in image-forming systems. In order to analyze the characteristics of the image-forming system at a full range, on the basis of photometry, the formulas to calculate the illumination of the imaging plane have been summarized by the numbers. Moreover, the relationship between the horizontal offset of the light source and the illumination of the image has been discussed in detail. After that, the influence of some key factors such as aperture angle, off-axis distance and horizontal offset on illumination of the image has been brought forward. Through numerical simulation, various theoretical curves of those key factors have been given. The results of the numerical simulation show that it is recommended to aggrandize the diameter of the exit pupil to increase the illumination of the image. The angle of view plays a negative role in the illumination distribution of the image, that is, the uniformity of the illumination distribution can be enhanced by compressing the angle of view. Lastly, it is proved that telecentric optical design is an effective way to advance the uniformity of the illumination distribution.

  15. First light of Cassis: the stereo surface imaging system onboard the exomars TGO

    Science.gov (United States)

    Gambicorti, L.; Piazza, D.; Pommerol, A.; Roloff, V.; Gerber, M.; Ziethe, R.; El-Maarry, M. R.; Weigel, T.; Johnson, M.; Vernani, D.; Pelo, E.; Da Deppo, V.; Cremonese, G.; Ficai Veltroni, I.; Thomas, N.

    2017-09-01

    The Colour and Stereo Surface Imaging System (CaSSIS) camera was launched on 14 March 2016 onboard the ExoMars Trace Gas Orbiter (TGO) and it is currently in cruise to Mars. The CaSSIS high resolution optical system is based on a TMA telescope (Three Mirrors Anastigmatic configuration) with a 4th powered folding mirror compacting the CFRP (Carbon Fiber Reinforced Polymer) structure. The camera EPD (Entrance Pupil Diameter) is 135 mm and the focal length is 880 mm, giving an F# 6.5 system; the wavelength range covered by the instrument is 400-1100 nm. The optical system is designed to have distortion of less than 2%, and a worst case Modulation Transfer Function (MTF) of 0.3 at the detector Nyquist spatial frequency (i.e. 50 lp/mm). The Focal Plane Assembly (FPA), including the detector, is a spare from the Simbio-Sys instrument of the Italian Space Agency (ASI). Simbio-Sys will fly on ESA's BepiColombo mission to Mercury in 2018. The detector, developed by Raytheon Vision Systems, is a 2k×2k hybrid Si-PIN array with 10 μm-pixel pitch. The detector allows snap shot operation at a read-out rate of 5 Mpx/s with 14-bit resolution. CaSSIS will operate in a push-frame mode with a Filter Strip Assembly (FSA), placed directly above the detector sensitive area, selecting 4 colour bands. The scale at a slant angle of 4.6 m/px from the nominal orbit is foreseen to produce frames of 9.4 km × 6.3 km on the Martian surface, and covering a Field of View (FoV) of 1.33° cross track × 0.88° along track. The University of Bern was in charge of the full instrument integration as well as the characterisation of the focal plane of CaSSIS. The paper will present an overview of CaSSIS and the optical performance of the telescope and the FPA. The preliminary results of the on-ground calibration campaign and the first light obtained during the commissioning and pointing campaign (April 2016) will be described in detail. The instrument is acquiring images with an average Point Spread

  16. Motion Tracking for Medical Imaging: A Non-Visible Structured Light Tracking Approach

    DEFF Research Database (Denmark)

    Olesen, Oline Vinter; Paulsen, Rasmus Reinhold; Højgaard, Liselotte

    2012-01-01

    We present a system for head motion tracking in 3D brain imaging. The system is based on facial surface reconstruction and tracking using a structured light (SL) scanning principle. The system is designed to fit into narrow 3D medical scanner geometries limiting the field of view. It is tested......, is that it is not necessary to place markers on the patient. This provides a simpler workflow and eliminates uncertainties related to marker attachment and stability. We show proof of concept of a marker less tracking system especially designed for clinical use with promising results....... in a clinical setting on the high resolution research tomograph (HRRT), Siemens PET scanner with a head phantom and volunteers. The SL system is compared to a commercial optical tracking system, the Polaris Vicra system, from NDI based on translatory and rotary ground truth motions of the head phantom...

  17. Imaging performance of annular apertures. VI - Limitations by optical surface deviations

    Science.gov (United States)

    Tschunko, Hubert F. A.

    1987-01-01

    The performance of optical systems is limited by imperfect optical surfaces that degrade the images below the level set by wave theoretical limits. The central irradiance functions are derived for slit and circular apertures with five distributions of wavefront errors and for a range of maximal wavefront deviations. For practical frequency of occurrence distributions of wavefront deviations, the point spread and the image energy integral functions are determined. Practical performances of optical systems are derived and performance limits discussed.

  18. MALDI-MS Imaging Analysis of Fungicide Residue Distributions on Wheat Leaf Surfaces.

    Science.gov (United States)

    Annangudi, Suresh P; Myung, Kyung; Avila Adame, Cruz; Gilbert, Jeffrey R

    2015-05-05

    Improved retention and distribution of agrochemicals on plant surfaces is an important attribute in the biological activity of pesticide. Although retention of agrochemicals on plants after spray application can be quantified using traditional analytical techniques including LC or GC, the spatial distribution of agrochemicals on the plants surfaces has received little attention. Matrix assisted laser desorption/ionization (MALDI) imaging technology has been widely used to determine the distribution of proteins, peptides and metabolites in different tissue sections, but its application to environmental research has been limited. Herein, we probed the potential utility of MALDI imaging in characterizing the distribution of three commercial fungicides on wheat leaf surfaces. Using this MALDI imaging method, we were able to detect 500 ng of epoxiconazole, azoxystrobin, and pyraclostrobin applied in 1 μL drop on the leaf surfaces using MALDI-MS. Subsequent dilutions of pyraclostrobin revealed that the compound can be chemically imaged on the leaf surfaces at levels as low as 60 ng of total applied in the area of 1 μL droplet. After application of epoxiconazole, azoxystrobin, and pyraclostrobin at a field rate of 100 gai/ha in 200 L water using a track sprayer system, residues of these fungicides on the leaf surfaces were sufficiently visualized. These results suggest that MALDI imaging can be used to monitor spatial distribution of agrochemicals on leaf samples after pesticide application.

  19. Fluorescence Imaging Reveals Surface Contamination

    Science.gov (United States)

    Schirato, Richard; Polichar, Raulf

    1992-01-01

    In technique to detect surface contamination, object inspected illuminated by ultraviolet light to make contaminants fluoresce; low-light-level video camera views fluorescence. Image-processing techniques quantify distribution of contaminants. If fluorescence of material expected to contaminate surface is not intense, tagged with low concentration of dye.

  20. Unveiling NIR Aza-Boron-Dipyrromethene (BODIPY) Dyes as Raman Probes: Surface-Enhanced Raman Scattering (SERS)-Guided Selective Detection and Imaging of Human Cancer Cells.

    Science.gov (United States)

    Adarsh, Nagappanpillai; Ramya, Adukkadan N; Maiti, Kaustabh Kumar; Ramaiah, Danaboyina

    2017-10-12

    The development of new Raman reporters has attracted immense attention in diagnostic research based on surface enhanced Raman scattering (SERS) techniques, which is a well established method for ultrasensitive detection through molecular fingerprinting and imaging. Herein, for the first time, we report the unique and efficient Raman active features of the selected aza-BODIPY dyes 1-6. These distinctive attributes could be extended at the molecular level to allow detection through SERS upon adsorption onto nano-roughened gold surface. Among the newly revealed Raman reporters, the amino substituted derivative 4 showed high signal intensity at very low concentrations (ca. 0.4 μm for 4-Au). Interestingly, an efficient nanoprobe has been constructed by using gold nanoparticles as SERS substrate, and 4 as the Raman reporter (4-Au@PEG), which unexpectedly showed efficient recognition of three human cancer cells (lung: A549, cervical: HeLa, Fibrosarcoma: HT-1080) without any specific surface marker. We observed well reflected and resolved Raman mapping and characteristic signature peaks whereas, such recognition was not observed in normal fibroblast (3T3L1) cells. To confirm these findings, a SERS nanoprobe was conjugated with a specific tumour targeting marker, EGFR (Epidermal Growth Factor Receptor), a well known targeted agent for Human Fibrosarcoma (HT1080). This nanoprobe efficiently targeted the surface marker of HT1080 cells, threreby demonstrating its use as an ultrasensitive Raman probe for detection and targeted imaging, leaving normal cells unaffected. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Poster – 41: External marker block placement on the breast or chest wall for left-sided deep inspiration breath-hold radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Conroy, Leigh; Guebert, Alexandra; Smith, Wendy [Tom Baker Cancer Centre (Canada)

    2016-08-15

    Purpose: We investigate DIBH breast radiotherapy using the Real-time Position Management (RPM) system with the marker-block placed on the target breast or chest wall. Methods: We measured surface dose for three different RPM marker-blocks using EBT3 Gafchromic film at 0° and 30° incidence. A registration study was performed to determine the breast surface position that best correlates with overall internal chest wall position. Surface and chest wall contours from MV images of the medial tangent field were extracted for 15 patients. Surface contours were divided into three potential marker-block positions on the breast: Superior, Middle, and Inferior. Translational registration was used to align the partial contours to the first-fraction contour. Each resultant transformation matrix was applied to the chest wall contour, and the minimum distance between the reference chest wall contour and the transformed chest wall contour was evaluated for each pixel. Results: The measured surface dose for the 2-dot, 6-dot, and 4-dot marker-blocks at 0° incidence were 74%, 71%, and 77% of dose to dmax respectively. At 30° beam incidence this increased to 76%, 72%, and 81%. The best external surface position was patient and fraction dependent, with no consistent best choice. Conclusions: The increase in surface dose directly under the RPM block is approximately equivalent to 3 mm of bolus. No marker-block position on the breast surface was found to be more representative of overall chest wall motion; therefore block positional stability and reproducibility can be used to determine optimal placement on the breast or chest wall.

  2. Surface scanning through a cylindrical tank of coupling fluid for clinical microwave breast imaging exams

    International Nuclear Information System (INIS)

    Pallone, Matthew J.; Meaney, Paul M.; Paulsen, Keith D.

    2012-01-01

    Purpose: Microwave tomographic image quality can be improved significantly with prior knowledge of the breast surface geometry. The authors have developed a novel laser scanning system capable of accurately recovering surface renderings of breast-shaped phantoms immersed within a cylindrical tank of coupling fluid which resides completely external to the tank (and the aqueous environment) and overcomes the challenges associated with the optical distortions caused by refraction from the air, tank wall, and liquid bath interfaces. Methods: The scanner utilizes two laser line generators and a small CCD camera mounted concentrically on a rotating gantry about the microwave imaging tank. Various calibration methods were considered for optimizing the accuracy of the scanner in the presence of the optical distortions including traditional ray tracing and image registration approaches. In this paper, the authors describe the construction and operation of the laser scanner, compare the efficacy of several calibration methods—including analytical ray tracing and piecewise linear, polynomial, locally weighted mean, and thin-plate-spline (TPS) image registrations—and report outcomes from preliminary phantom experiments. Results: The results show that errors in calibrating camera angles and position prevented analytical ray tracing from achieving submillimeter accuracy in the surface renderings obtained from our scanner configuration. Conversely, calibration by image registration reliably attained mean surface errors of less than 0.5 mm depending on the geometric complexity of the object scanned. While each of the image registration approaches outperformed the ray tracing strategy, the authors found global polynomial methods produced the best compromise between average surface error and scanner robustness. Conclusions: The laser scanning system provides a fast and accurate method of three dimensional surface capture in the aqueous environment commonly found in microwave

  3. Superresolution Near-field Imaging with Surface Waves

    KAUST Repository

    Fu, Lei

    2017-10-21

    We present the theory for near-field superresolution imaging with surface waves and time reverse mirrors (TRMs). Theoretical formulas and numerical results show that applying the TRM operation to surface waves in an elastic half-space can achieve superresolution imaging of subwavelength scatterers if they are located less than about 1/2 of the shear wavelength from the source line. We also show that the TRM operation for a single frequency is equivalent to natural migration, which uses the recorded data to approximate the Green’s functions for migration, and only costs O(N4) algebraic operations for poststack migration compared to O(N6) operations for natural prestack migration. Here, we assume the sources and receivers are on an N × N grid and there are N2 trial image points on the free surface. Our theoretical predictions of superresolution are validated with tests on synthetic data. The field-data tests suggest that hidden faults at the near surface can be detected with subwavelength imaging of surface waves by using the TRM operation if they are no deeper than about 1/2 the dominant shear wavelength.

  4. [Surface coils for magnetic-resonance images].

    Science.gov (United States)

    Rodríguez-González, Alfredo Odón; Amador-Baheza, Ricardo; Rojas-Jasso, Rafael; Barrios-Alvarez, Fernando Alejandro

    2005-01-01

    Since the introduction of magnetic resonance imaging in Mexico, the development of this important medical imaging technology has been almost non-existing in our country. The very first surface coil prototypes for clinical applications in magnetic resonance imaging has been developed at the Center of Research in Medical Imaging and Instrumentation of the Universidad Autónoma Metropolitana Iztapalapa (Metropolitan Autonomous University, Campus Iztapalapa). Two surface coil prototypes were built: a) a circular-shaped coil and b) a square-shaped coil for multiple regions of the body, such as heart, brain, knee, hands, and ankles. These coils were tested on the 1.5T imager of the ABC Hospital-Tacubaya, located in Mexico City. Brain images of healthy volunteers were obtained in different orientations: sagittal, coronal, and axial. Since images showed a good-enough clinical quality for diagnosis, it is fair to say that these coil prototypes can be used in the clinical environment, and with small modifications, they can be made compatible with almost any commercial scanner. This type of development can offer new alternatives for further collaboration between the research centers and the radiology community, in the search of new applications and developments of this imaging technique.

  5. Textural Analysis of Fatique Crack Surfaces: Image Pre-processing

    Directory of Open Access Journals (Sweden)

    H. Lauschmann

    2000-01-01

    Full Text Available For the fatique crack history reconstitution, new methods of quantitative microfractography are beeing developed based on the image processing and textural analysis. SEM magnifications between micro- and macrofractography are used. Two image pre-processing operatins were suggested and proved to prepare the crack surface images for analytical treatment: 1. Normalization is used to transform the image to a stationary form. Compared to the generally used equalization, it conserves the shape of brightness distribution and saves the character of the texture. 2. Binarization is used to transform the grayscale image to a system of thick fibres. An objective criterion for the threshold brightness value was found as that resulting into the maximum number of objects. Both methods were succesfully applied together with the following textural analysis.

  6. Morphological hippocampal markers for automated detection of Alzheimer's disease and mild cognitive impairment converters in magnetic resonance images.

    Science.gov (United States)

    Ferrarini, Luca; Frisoni, Giovanni B; Pievani, Michela; Reiber, Johan H C; Ganzola, Rossana; Milles, Julien

    2009-01-01

    In this study, we investigated the use of hippocampal shape-based markers for automatic detection of Alzheimer's disease (AD) and mild cognitive impairment converters (MCI-c). Three-dimensional T1-weighted magnetic resonance images of 50 AD subjects, 50 age-matched controls, 15 MCI-c, and 15 MCI-non-converters (MCI-nc) were taken. Manual delineations of both hippocampi were obtained from normalized images. Fully automatic shape modeling was used to generate comparable meshes for both structures. Repeated permutation tests, run over a randomly sub-sampled training set (25 controls and 25 ADs), highlighted shape-based markers, mostly located in the CA1 sector, which consistently discriminated ADs and controls. Support vector machines (SVMs) were trained, using markers from either one or both hippocampi, to automatically classify control and AD subjects. Leave-1-out cross-validations over the remaining 25 ADs and 25 controls resulted in an optimal accuracy of 90% (sensitivity 92%), for markers in the left hippocampus. The same morphological markers were used to train SVMs for MCI-c versus MCI-nc classification: markers in the right hippocampus reached an accuracy (and sensitivity) of 80%. Due to the pattern recognition framework, our results statistically represent the expected performances of clinical set-ups, and compare favorably to analyses based on hippocampal volumes.

  7. Ghost marker detection and elimination in marker-based optical tracking systems for real-time tracking in stereotactic body radiotherapy

    International Nuclear Information System (INIS)

    Yan, Guanghua; Li, Jonathan; Huang, Yin; Mittauer, Kathryn; Lu, Bo; Liu, Chihray

    2014-01-01

    Purpose: To propose a simple model to explain the origin of ghost markers in marker-based optical tracking systems (OTS) and to develop retrospective strategies to detect and eliminate ghost markers. Methods: In marker-based OTS, ghost markers are virtual markers created due to the cross-talk between the two camera sensors, which can lead to system execution failure or inaccuracy in patient tracking. As a result, the users have to limit the number of markers and avoid certain marker configurations to reduce the chances of ghost markers. In this work, the authors propose retrospective strategies to detect and eliminate ghost markers. The two camera sensors were treated as mathematical points in space. The authors identified the coplanar within limit (CWL) condition as the necessary condition for ghost marker occurrence. A simple ghost marker detection method was proposed based on the model. Ghost marker elimination was achieved through pattern matching: a ghost marker-free reference set was matched with the optical marker set observed by the OTS; unmatched optical markers were eliminated as either ghost markers or misplaced markers. The pattern matching problem was formulated as a constraint satisfaction problem (using pairwise distances as constraints) and solved with an iterative backtracking algorithm. Wildcard markers were introduced to address missing or misplaced markers. An experiment was designed to measure the sensor positions and the limit for the CWL condition. The ghost marker detection and elimination algorithms were verified with samples collected from a five-marker jig and a nine-marker anthropomorphic phantom, rotated with the treatment couch from −60° to +60°. The accuracy of the pattern matching algorithm was further validated with marker patterns from 40 patients who underwent stereotactic body radiotherapy (SBRT). For this purpose, a synthetic optical marker pattern was created for each patient by introducing ghost markers, marker position

  8. Ghost marker detection and elimination in marker-based optical tracking systems for real-time tracking in stereotactic body radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Guanghua, E-mail: yan@ufl.edu; Li, Jonathan; Huang, Yin; Mittauer, Kathryn; Lu, Bo; Liu, Chihray [Department of Radiation Oncology, University of Florida, Gainesville, Florida 32610 (United States)

    2014-10-15

    Purpose: To propose a simple model to explain the origin of ghost markers in marker-based optical tracking systems (OTS) and to develop retrospective strategies to detect and eliminate ghost markers. Methods: In marker-based OTS, ghost markers are virtual markers created due to the cross-talk between the two camera sensors, which can lead to system execution failure or inaccuracy in patient tracking. As a result, the users have to limit the number of markers and avoid certain marker configurations to reduce the chances of ghost markers. In this work, the authors propose retrospective strategies to detect and eliminate ghost markers. The two camera sensors were treated as mathematical points in space. The authors identified the coplanar within limit (CWL) condition as the necessary condition for ghost marker occurrence. A simple ghost marker detection method was proposed based on the model. Ghost marker elimination was achieved through pattern matching: a ghost marker-free reference set was matched with the optical marker set observed by the OTS; unmatched optical markers were eliminated as either ghost markers or misplaced markers. The pattern matching problem was formulated as a constraint satisfaction problem (using pairwise distances as constraints) and solved with an iterative backtracking algorithm. Wildcard markers were introduced to address missing or misplaced markers. An experiment was designed to measure the sensor positions and the limit for the CWL condition. The ghost marker detection and elimination algorithms were verified with samples collected from a five-marker jig and a nine-marker anthropomorphic phantom, rotated with the treatment couch from −60° to +60°. The accuracy of the pattern matching algorithm was further validated with marker patterns from 40 patients who underwent stereotactic body radiotherapy (SBRT). For this purpose, a synthetic optical marker pattern was created for each patient by introducing ghost markers, marker position

  9. Direct UV/Optical Imaging of Stellar Surfaces: The Stellar Imager (SI) Vision Mission

    Science.gov (United States)

    Carpenter, Kenneth G.; Lyon, Richard G.; Schrijver, Carolus; Karovska, Margarita; Mozurkewich, David

    2007-01-01

    The Stellar Imager (SI) is a UV/optical, space-based interferometer designed to enable 0.1 milli-arcsecond (mas) spectral imaging of stellar surfaces and, via asteroseismology, stellar interiors and of the Universe in general. SI's science focuses on the role of magnetism in the Universe, particularly on magnetic activity on the surfaces of stars like the Sun. SI's prime goal is to enable long-term forecasting of solar activity and the space weather that it drives, in support of the Living with a Star program in the Exploration Era. SI will also revolutionize our understanding of the formation of planetary systems, of the habitability and climatology of distant planets, and of many magneto-hydrodynamically controlled processes in thc Universe. SI is a "Flagship and Landmark Discovery Mission" in the 2005 Sun Solar System Connection (SSSC) Roadmap and a candidate for a "Pathways to Life Observatory" in the Exploration of the Universe Division (EUD) Roadmap. We discuss herein the science goals of the SI Mission, a mission architecture that could meet those goals, and the technologies needed to enable this mission. Additional information on SI can be found at: http://hires.gsfc.nasa.gov/si/.

  10. Validation of tumor protein marker quantification by two independent automated immunofluorescence image analysis platforms

    Science.gov (United States)

    Peck, Amy R; Girondo, Melanie A; Liu, Chengbao; Kovatich, Albert J; Hooke, Jeffrey A; Shriver, Craig D; Hu, Hai; Mitchell, Edith P; Freydin, Boris; Hyslop, Terry; Chervoneva, Inna; Rui, Hallgeir

    2016-01-01

    Protein marker levels in formalin-fixed, paraffin-embedded tissue sections traditionally have been assayed by chromogenic immunohistochemistry and evaluated visually by pathologists. Pathologist scoring of chromogen staining intensity is subjective and generates low-resolution ordinal or nominal data rather than continuous data. Emerging digital pathology platforms now allow quantification of chromogen or fluorescence signals by computer-assisted image analysis, providing continuous immunohistochemistry values. Fluorescence immunohistochemistry offers greater dynamic signal range than chromogen immunohistochemistry, and combined with image analysis holds the promise of enhanced sensitivity and analytic resolution, and consequently more robust quantification. However, commercial fluorescence scanners and image analysis software differ in features and capabilities, and claims of objective quantitative immunohistochemistry are difficult to validate as pathologist scoring is subjective and there is no accepted gold standard. Here we provide the first side-by-side validation of two technologically distinct commercial fluorescence immunohistochemistry analysis platforms. We document highly consistent results by (1) concordance analysis of fluorescence immunohistochemistry values and (2) agreement in outcome predictions both for objective, data-driven cutpoint dichotomization with Kaplan–Meier analyses or employment of continuous marker values to compute receiver-operating curves. The two platforms examined rely on distinct fluorescence immunohistochemistry imaging hardware, microscopy vs line scanning, and functionally distinct image analysis software. Fluorescence immunohistochemistry values for nuclear-localized and tyrosine-phosphorylated Stat5a/b computed by each platform on a cohort of 323 breast cancer cases revealed high concordance after linear calibration, a finding confirmed on an independent 382 case cohort, with concordance correlation coefficients >0

  11. Atomic profile imaging of ceramic oxide surfaces

    International Nuclear Information System (INIS)

    Bursill, L.A.; Peng JuLin; Sellar, J.R.

    1989-01-01

    Atomic surface profile imaging is an electron optical technique capable of revealing directly the surface crystallography of ceramic oxides. Use of an image-intensifier with a TV camera allows fluctuations in surface morphology and surface reactivity to be recorded and analyzed using digitized image data. This paper reviews aspects of the electron optical techniques, including interpretations based upon computer-simulation image-matching techniques. An extensive range of applications is then presented for ceramic oxides of commercial interest for advanced materials applications: including uranium oxide (UO 2 ); magnesium and nickel oxide (MgO,NiO); ceramic superconductor YBa 2 Cu 3 O 6.7 ); barium titanate (BaTiO 3 ); sapphire (α-A1 2 O 3 ); haematite (α-Fe-2O 3 ); monoclinic, tetragonal and cubic monocrystalline forms of zirconia (ZrO 2 ), lead zirconium titanate (PZT + 6 mol.% NiNbO 3 ) and ZBLAN fluoride glass. Atomic scale detail has been obtained of local structures such as steps associated with vicinal surfaces, facetting parallel to stable low energy crystallographic planes, monolayer formation on certain facets, relaxation and reconstructions, oriented overgrowth of lower oxides, chemical decomposition of complex oxides into component oxides, as well as amorphous coatings. This remarkable variety of observed surface stabilization mechanisms is discussed in terms of novel double-layer electrostatic depolarization mechanisms, as well as classical concepts of the physics and chemistry of surfaces (ionization and affinity energies and work function). 46 refs., 16 figs

  12. Fourier and granulometry methods on 3D images of soil surfaces for evaluating soil aggregate size distribution

    DEFF Research Database (Denmark)

    Jensen, T.; Green, O.; Munkholm, Lars Juhl

    2016-01-01

    The goal of this research is to present and compare two methods for evaluating soil aggregate size distribution based on high resolution 3D images of the soil surface. The methods for analyzing the images are discrete Fourier transform and granulometry. The results of these methods correlate...... with a measured weight distribution of the soil aggregates. The results have shown that it is possible to distinguish between the cultivated and the uncultivated soil surface. A sensor system suitable for capturing in-situ high resolution 3D images of the soil surface is also described. This sensor system...

  13. Lack of correlation between immunologic markers and cell surface ultrastructure in the leukemic phase of lymphoproliferative diseases

    Energy Technology Data Exchange (ETDEWEB)

    Golomb, Harvey M.; Simon, Deberah

    1977-01-01

    In a prospective study of malignant cells from 13 patients with the leukemic phase of lymphoproliferative diseases, we wished to determine whether any correlation between the immunologic markers and the cell surface ultrastructure. Five patients had chronic lymphocytic leukemia, four had malignant lymphomas, poorly differentiated lymphocytic type, two had the Sezary syndrome, and one each had acute prolymphocytic leukemia and acute lymphocytic leukemia. Cell separation and isolation was done at room temperature for all specimens. Immunologic markers tested for were surface immunoglobins, a B-cell property, and E-rosettes, a T-cell property. Three patients had T-cell diseases, 6 had B-cell diseases, and 4 were classified as ''null.'' All but one patient had moderate to large numbers of microvilli on their malignant cells. The single exception had a typical B-cell form of chronic lymphocytic leukemia. There appears to be no correlation between immunologic markers and cell surface ultrastructure; therefore, SEM appears not to be valuable in the diagnosis or classification of immunologic sub-types of certain lymphoproliferative diseases.

  14. Cell surface expression of single chain antibodies with applications to imaging of gene expression in vivo

    International Nuclear Information System (INIS)

    Northrop, Jeffrey P.; Bednarski, Mark; Li, King C.; Barbieri, Susan O.; Lu, Amy T.; Nguyen, Dee; Varadarajan, John; Osen, Maureen; Star-Lack, Josh

    2003-01-01

    Imaging of gene expression in vivo has many potential uses for biomedical research and drug discovery, ranging from the study of gene regulation and cancer to the non-invasive assessment of gene therapies. To streamline the development of imaging marker gene technologies for nuclear medicine, we propose a new approach to the design of reporter/probe pairs wherein the reporter is a cell surface-expressed single chain antibody variable fragment that has been raised against a low molecular weight imaging probe with optimized pharmacokinetic properties. Proof of concept of the approach was achieved using a single chain antibody variable fragment that binds with high affinity to fluorescein and an imaging probe consisting of fluorescein isothiocyanate coupled to the chelator diethylene triamine penta-acetic acid labeled with the gamma-emitter 111 In. We demonstrate specific high-affinity binding of this probe to the cell surface-expressed reporter in vitro and assess the in vivo biodistribution of the probe both in wild-type mice and in mice harboring tumor xenografts expressing the reporter. Specific uptake of the probe by, and in vivo imaging of, tumors expressing the reporter are shown. Since ScFvs with high affinities can be raised to almost any protein or small molecule, the proposed methodology may offer a new flexibility in the design of imaging tracer/reporter pairs wherein both probe pharmacokinetics and binding affinities can be readily optimized. (orig.)

  15. SU-F-J-20: Commissioning and Acceptance Testing of the C-Rad CatalystHD Surface Imaging System

    International Nuclear Information System (INIS)

    Stanley, D; Rasmussen, K; Kirby, N; Papanikolaou, N; Gutierrez, A

    2016-01-01

    Introduction: With the increasing use of surface-based, nonionizing image-guided radiotherapy (IGRT) systems, a comprehensive set of clinical acceptance and commissioning procedures are needed to ensure correct functionality and proper clinical integration. Although TG-147 provides a specific set of parameters, measurement methodologies have yet to be described. The aim of this study was to provide a comprehensive overview of the commissioning and acceptance analysis performed for the C-Rad CatalystHD imaging system. Methods and Materials: Methodology for the commissioning and acceptance of the C-Rad CatalystHD imaging system was developed using commercially available clinical equipment. Following TG-147 guidelines, the following tests were performed: integration of peripheral equipment, system drift, static spatial reproducibility and localization accuracy, static end-to-end analysis, static rotational accuracy, dynamic spatial accuracy, dynamic temporal accuracy, dynamic radiation delivery and a comprehensive end-to-end analysis. Results: The field of view (FOV) of the CatalystHD was 105×109×83 cm3 in the lateral, longitudinal and vertical directions. For thermal equilibrium and system drift, a thermal drift of 1.0mm was noted. A 45 min warmup time is recommended if the system has been shut off an extended period of time (>24 hours) before the QA procedure to eliminate any thermal drift. Spatial reproducibility was found to be 0.05±0.03 mm using a rigid phantom. For the static localization accuracy, system agreement with couch shifts was within 0.1±0.1 mm and positioning agreement with kV-CBCT was 0.16±0.10 mm. For static rotational accuracy, system agreement with a high precision rotational stage (0.01 deg precision) was within 0.10±0.07 deg. Dynamic spatial and temporal localization accuracy was found to be within 0.2±0.1 mm. Conclusion: A comprehensive commissioning and acceptance study was performed using commercially available phantoms and in

  16. Identification and validation of multiple cell surface markers of clinical-grade adipose-derived mesenchymal stromal cells as novel release criteria for good manufacturing practice-compliant production.

    Science.gov (United States)

    Camilleri, Emily T; Gustafson, Michael P; Dudakovic, Amel; Riester, Scott M; Garces, Catalina Galeano; Paradise, Christopher R; Takai, Hideki; Karperien, Marcel; Cool, Simon; Sampen, Hee-Jeong Im; Larson, A Noelle; Qu, Wenchun; Smith, Jay; Dietz, Allan B; van Wijnen, Andre J

    2016-08-11

    Clinical translation of mesenchymal stromal cells (MSCs) necessitates basic characterization of the cell product since variability in biological source and processing of MSCs may impact therapeutic outcomes. Although expression of classical cell surface markers (e.g., CD90, CD73, CD105, and CD44) is used to define MSCs, identification of functionally relevant cell surface markers would provide more robust release criteria and options for quality control. In addition, cell surface expression may distinguish between MSCs from different sources, including bone marrow-derived MSCs and clinical-grade adipose-derived MSCs (AMSCs) grown in human platelet lysate (hPL). In this work we utilized quantitative PCR, flow cytometry, and RNA-sequencing to characterize AMSCs grown in hPL and validated non-classical markers in 15 clinical-grade donors. We characterized the surface marker transcriptome of AMSCs, validated the expression of classical markers, and identified nine non-classical markers (i.e., CD36, CD163, CD271, CD200, CD273, CD274, CD146, CD248, and CD140B) that may potentially discriminate AMSCs from other cell types. More importantly, these markers exhibit variability in cell surface expression among different cell isolates from a diverse cohort of donors, including freshly prepared, previously frozen, or proliferative state AMSCs and may be informative when manufacturing cells. Our study establishes that clinical-grade AMSCs expanded in hPL represent a homogeneous cell culture population according to classical markers,. Additionally, we validated new biomarkers for further AMSC characterization that may provide novel information guiding the development of new release criteria. Use of Autologous Bone Marrow Aspirate Concentrate in Painful Knee Osteoarthritis (BMAC): Clinicaltrials.gov NCT01931007 . Registered August 26, 2013. MSC for Occlusive Disease of the Kidney: Clinicaltrials.gov NCT01840540 . Registered April 23, 2013. Mesenchymal Stem Cell Therapy in Multiple

  17. Visibility of fiducial markers used for image-guided radiation therapy on optical coherence tomography for registration with CT: An esophageal phantom study.

    Science.gov (United States)

    Jelvehgaran, Pouya; Alderliesten, Tanja; Weda, Jelmer J A; de Bruin, Martijn; Faber, Dirk J; Hulshof, Maarten C C M; van Leeuwen, Ton G; van Herk, Marcel; de Boer, Johannes F

    2017-12-01

    Optical coherence tomography (OCT) is of interest to visualize microscopic esophageal tumor extensions to improve tumor delineation for radiation therapy (RT) planning. Fiducial marker placement is a common method to ensure target localization during planning and treatment. Visualization of these fiducial markers on OCT permits integrating OCT and computed tomography (CT) images used for RT planning via image registration. We studied the visibility of 13 (eight types) commercially available solid and liquid fiducial markers in OCT images at different depths using dedicated esophageal phantoms and evaluated marker placement depth in clinical practice. We designed and fabricated dedicated esophageal phantoms, in which three layers mimic the anatomical wall structures of a healthy human esophagus. We successfully implanted 13 commercially available fiducial markers that varied in diameter and material property at depths between 0.5 and 3.0 mm. The resulting esophageal phantoms were imaged with OCT, and marker visibility was assessed qualitatively and quantitatively using the contrast-to-background-noise ratio (CNR). The CNR was defined as the difference between the mean intensity of the fiducial markers and the mean intensity of the background divided by the standard deviation of the background intensity. To determine whether, in current clinical practice, the implanted fiducial markers are within the OCT visualization range (up to 3.0 mm depth), we retrospectively measured the distance of 19 fiducial markers to the esophageal lumen on CT scans of 16 esophageal cancer patients. In the esophageal phantoms, all the included fiducial markers were visible on OCT at all investigated depths. Solid fiducial markers were better visible on OCT than liquid fiducial markers with a 1.74-fold higher CNR. Although fiducial marker identification per type and size was slightly easier for superficially implanted fiducial markers, we observed no difference in the ability of OCT to

  18. Utility of MRI versus tumor markers for post-treatment surveillance of marker-positive CNS germ cell tumors.

    Science.gov (United States)

    Cheung, Victoria; Segal, Devorah; Gardner, Sharon L; Zagzag, David; Wisoff, Jeffrey H; Allen, Jeffrey C; Karajannis, Matthias A

    2016-09-01

    Patients with marker-positive central nervous system (CNS) germ cell tumors are typically monitored for tumor recurrence with both tumor markers (AFP and b-hCG) and MRI. We hypothesize that the recurrence of these tumors will always be accompanied by an elevation in tumor markers, and that surveillance MRI may not be necessary. We retrospectively identified 28 patients with CNS germ cell tumors treated at our institution that presented with an elevated serum or cerebrospinal fluid (CSF) tumor marker at the time of diagnosis. We then identified those who had a tumor recurrence after having been in remission and whether each recurrence was detected via MRI changes, elevated tumor markers, or both. Four patients suffered a tumor recurrence. Only one patient had simultaneously elevated tumor markers and MRI evidence of recurrence. Two patients had evidence of recurrence on MRI without corresponding elevations in serum or CSF tumor markers. One patient had abnormal tumor markers with no evidence of recurrence on MRI until 6 months later. We conclude that in patients with marker-positive CNS germ cell tumors who achieve complete remission, continued surveillance imaging in addition to measurement of tumor markers is indicated to detect recurrences.

  19. A noncontact laser system for measuring soil surface topography

    International Nuclear Information System (INIS)

    Huang, C.; White, I.; Thwaite, E.G.; Bendeli, A.

    1988-01-01

    Soil surface topography profoundly influences runoff hydrodynamics, soil erosion, and surface retention of water. Here we describe an optical noncontact system for measuring soil surface topography. Soil elevation is measured by projecting a laser beam onto the surface and detecting the position of the interception point. The optical axis of the detection system is oriented at a small angle to the incident beam. A low-power HeNe (Helium-Neon) laser is used as the laser source, a photodiode array is used as the laser image detector and an ordinary 35-mm single lens reflex camera provides the optical system to focus the laser image onto the diode array. A wide spectrum of measurement ranges (R) and resolutions are selectable, from 1 mm to 1 m. These are determined by the laser-camera distance and angle, the focal length of the lens, and the sensing length of the diode array and the number of elements (N) contained in the array. The resolution of the system is approximately R/2N. We show for the system used here that this resolution is approximately 0.2%. In the configuration selected, elevation changes of 0.16 mm could be detected over a surface elevation range of 87 mm. The sampling rate of the system is 1000 Hz, which permits soil surfaces to be measured at speeds of up to 1 m s −1 with measurements taken at 1-mm spacing. Measurements of individual raindrop impacts on the soil and of soil surfaces before and after rain show the versatility of the laser surface profiler, which has applications in studies of erosion processes, surface storage and soil trafficability

  20. Fluorescence spectral imaging as a tool for locating uranium deposited on surfaces - 16089

    International Nuclear Information System (INIS)

    Monts, David L.; Wang, Guangjun; Su, Yi; Jang, Ping-Rey; Waggoner, Charles A.

    2009-01-01

    In the environment, metallic uranium readily oxidizes to form uranium compounds that contain the uranyl (UO 2 +2 ) moiety. For more than a hundred and fifty years, it has been known that when illuminated with ultraviolet (UV) light, uranyl compounds exhibit characteristic fluorescence in the visible region (450-650 nm). We report our efforts to develop a transportable, quantitative Fluorescence Spectral Imaging (FSI) system as a tool for locating and quantifying uranyl compounds dispersed in soils and on other surfaces. A project is underway to develop a set of sensors to locate expended depleted uranium (DU) rounds and to process soil and debris to recover the material from domestic firing ranges. The FSI system can also be utilized to monitor excavation of DU munitions and separation of uranyl compounds from soils. FSI images are acquired by illuminating a surface with a UV light and using a narrow band pass filter on a camera, recording an image of the resulting fluorescence. The FSI image provides both spatial and spectral information. The FSI system is described and its performance characterized using field samples. (authors)

  1. Dynamic Raman imaging system with high spatial and temporal resolution

    Science.gov (United States)

    Wang, Lei; Dai, Yinzhen; He, Hao; Lv, Ruiqi; Zong, Cheng; Ren, Bin

    2017-09-01

    There is an increasing need to study dynamic changing systems with significantly high spatial and temporal resolutions. In this work, we integrated point-scanning, line-scanning, and wide-field Raman imaging techniques into a single system. By using an Electron Multiplying CCD (EMCCD) with a high gain and high frame rate, we significantly reduced the time required for wide-field imaging, making it possible to monitor the electrochemical reactions in situ. The highest frame rate of EMCDD was ˜50 fps, and the Raman images for a specific Raman peak can be obtained by passing the signal from the sample through the Liquid Crystal Tunable Filter. The spatial resolutions of scanning imaging and wide-field imaging with a 100× objective (NA = 0.9) are 0.5 × 0.5 μm2 and 0.36 × 0.36 μm2, respectively. The system was used to study the surface plasmon resonance of Au nanorods, the surface-enhanced Raman scattering signal distribution for Au Nanoparticle aggregates, and dynamic Raman imaging of an electrochemical reacting system.

  2. Quantitative Evaluation of Surface Color of Tomato Fruits Cultivated in Remote Farm Using Digital Camera Images

    Science.gov (United States)

    Hashimoto, Atsushi; Suehara, Ken-Ichiro; Kameoka, Takaharu

    To measure the quantitative surface color information of agricultural products with the ambient information during cultivation, a color calibration method for digital camera images and a remote monitoring system of color imaging using the Web were developed. Single-lens reflex and web digital cameras were used for the image acquisitions. The tomato images through the post-ripening process were taken by the digital camera in both the standard image acquisition system and in the field conditions from the morning to evening. Several kinds of images were acquired with the standard RGB color chart set up just behind the tomato fruit on a black matte, and a color calibration was carried out. The influence of the sunlight could be experimentally eliminated, and the calibrated color information consistently agreed with the standard ones acquired in the system through the post-ripening process. Furthermore, the surface color change of the tomato on the tree in a greenhouse was remotely monitored during maturation using the digital cameras equipped with the Field Server. The acquired digital color images were sent from the Farm Station to the BIFE Laboratory of Mie University via VPN. The time behavior of the tomato surface color change during the maturing process could be measured using the color parameter calculated based on the obtained and calibrated color images along with the ambient atmospheric record. This study is a very important step in developing the surface color analysis for both the simple and rapid evaluation of the crop vigor in the field and to construct an ambient and networked remote monitoring system for food security, precision agriculture, and agricultural research.

  3. Assessment of Surface Markers Derived from Human Periodontal Ligament Stem Cells: An In Vitro Study

    Directory of Open Access Journals (Sweden)

    Zainab Kadkhoda

    2016-12-01

    Full Text Available Objectives: Periodontal tissue regeneration for treatment of periodontal disease has not yet been mastered in tissue engineering. Stem cells, scaffold, and growth factors are the three main basic components of tissue engineering. Periodontal ligament (PDL contains stem cells; however, the number, potency and features of these cells have not yet been understood. This study aimed to isolate and characterize the properties of PDL stem cells. Materials and Methods: In this experimental study, samples were isolated from the PDL of extracted teeth of five patients and then stained immunohistochemically for detection of cell surface markers. Cells were then examined by immuno-flow cytometry for mesenchymal markers as well as for osteogenic and adipogenic differentiation.Results: The isolated cell population had fibroblast-like morphology and flow cytometry revealed that the mesenchymal surface markers were (means: CD90 (84.55, CD31 (39.97, CD166 (33.77, CD105 (31.19, CD45 (32/44, CD44 (462.11, CD34 (227.33, CD38 (86.94, CD13 (34.52 and CD73 (50.39. The PDL stem cells also differentiated into osteoblasts and adipocytes in osteogenic and adipogenic media, respectively.Conclusions: PDL stem cells expressed mesenchymal stem cell (MSC markers and differentiated into osteoblasts and adipocytes in osteogenic and adipogenic media, respectively.Keywords: Adipocytes; Antigens; Mesenchymal Stromal Cells; Osteoblasts; Periodontal Ligament

  4. Injectable Colloidal Gold for Use in Intrafractional 2D Image-Guided Radiation Therapy

    DEFF Research Database (Denmark)

    Jølck, Rasmus Irming; Rydhog, Jonas S.; Christensen, Anders Nymark

    2015-01-01

    radio-opacity, which allows for marker-based image guidance in 2D and 3D X-ray imaging during radiation therapy. This is achieved by surface-engineering gold nanoparticles to be highly compatible with a carbohydrate-based gelation matrix. The new fiducial marker is investigated in mice where...

  5. A high-throughput surface plasmon resonance biosensor based on differential interferometric imaging

    International Nuclear Information System (INIS)

    Wang, Daqian; Ding, Lili; Zhang, Wei; Zhang, Enyao; Yu, Xinglong; Luo, Zhaofeng; Ou, Huichao

    2012-01-01

    A new high-throughput surface plasmon resonance (SPR) biosensor based on differential interferometric imaging is reported. The two SPR interferograms of the sensing surface are imaged on two CCD cameras. The phase difference between the two interferograms is 180°. The refractive index related factor (RIRF) of the sensing surface is calculated from the two simultaneously acquired interferograms. The simulation results indicate that the RIRF exhibits a linear relationship with the refractive index of the sensing surface and is unaffected by the noise, drift and intensity distribution of the light source. The affinity and kinetic information can be extracted in real time from continuously acquired RIRF distributions. The results of refractometry experiments show that the dynamic detection range of SPR differential interferometric imaging system can be over 0.015 refractive index unit (RIU). High refractive index resolution is down to 0.45 RU (1 RU = 1 × 10 −6 RIU). Imaging and protein microarray experiments demonstrate the ability of high-throughput detection. The aptamer experiments demonstrate that the SPR sensor based on differential interferometric imaging has a great capability to be implemented for high-throughput aptamer kinetic evaluation. These results suggest that this biosensor has the potential to be utilized in proteomics and drug discovery after further improvement. (paper)

  6. A New Sensor for Surface Process Quantification in the Geosciences - Image-Assisted Tacheometers

    Science.gov (United States)

    Vicovac, Tanja; Reiterer, Alexander; Rieke-Zapp, Dirk

    2010-05-01

    The quantification of earth surface processes in the geosciences requires precise measurement tools. Typical applications for precise measurement systems involve deformation monitoring for geo-risk management, detection of erosion rates, etc. Often employed for such applications are laser scanners, photogrammetric sensors and image-assisted tacheometers. Image-assisted tacheometers offer the user (metrology expert) an image capturing system (CCD/CMOS camera) in addition to 3D point measurements. The images of the telescope's visual field are projected onto the camera's chip. The camera is capable of capturing panoramic image mosaics through camera rotation if the axes of the measurement system are driven by computer controlled motors. With appropriate calibration, these images are accurately geo-referenced and oriented since the horizontal and vertical angles of rotation are continuously measured and fed into the computer. The oriented images can then directly be used for direction measurements with no need for control points in object space or further photogrammetric orientation processes. In such a system, viewing angles must be addressed to chip pixels inside the optical field of view. Hence dedicated calibration methods have to be applied, an autofocus unit has to be added to the optical path, and special digital image processing procedures have to be used to detect the points of interest on the objects to be measured. We present such a new optical measurement system for measuring and describing 3D surfaces for geosciences. Besides the technique and methods some practical examples will be shown. The system was developed at the Vienna University of Technology (Institute of Geodesy and Geophysics) - two interdisciplinary research project, i-MeaS and SedyMONT, have been launched with the purpose of measuring and interpreting 3D surfaces and surface processes. For the in situ measurement of bed rock erosion the level of surveying accuracy required for recurring sub

  7. Two small lymphocyte subpopulations in human peripheral blood. I. Purification and surface marker profiles

    DEFF Research Database (Denmark)

    Hokland, M; Hokland, P; Heron, I

    1978-01-01

    By means of simple rosette sedimentation methods two subsets from human peripheral blood lymphocytes have been isolated: (1) (E, Fc)- and (2) (E, Ig)-. The first subset was obtained by centrifuging suspensions of macrophage-depleted PBL in which E and EA rosettes had been allowed to form simultan......By means of simple rosette sedimentation methods two subsets from human peripheral blood lymphocytes have been isolated: (1) (E, Fc)- and (2) (E, Ig)-. The first subset was obtained by centrifuging suspensions of macrophage-depleted PBL in which E and EA rosettes had been allowed to form...... simultaneously. The dominant marker of these E- Fc- cells was surface Ig, and during 4 days of culture this population did not alter its surface markers. Subset 2 was obtained in two ways following rosette centrifugation with AET-treated SRBC and rabbit anti-human Ig-coated autologous RBC. This 'Null cell...

  8. Skin surface and sub-surface strain and deformation imaging using optical coherence tomography and digital image correlation

    Science.gov (United States)

    Hu, X.; Maiti, R.; Liu, X.; Gerhardt, L. C.; Lee, Z. S.; Byers, R.; Franklin, S. E.; Lewis, R.; Matcher, S. J.; Carré, M. J.

    2016-03-01

    Bio-mechanical properties of the human skin deformed by external forces at difference skin/material interfaces attract much attention in medical research. For instance, such properties are important design factors when one designs a healthcare device, i.e., the device might be applied directly at skin/device interfaces. In this paper, we investigated the bio-mechanical properties, i.e., surface strain, morphological changes of the skin layers, etc., of the human finger-pad and forearm skin as a function of applied pressure by utilizing two non-invasive techniques, i.e., optical coherence tomography (OCT) and digital image correlation (DIC). Skin deformation results of the human finger-pad and forearm skin were obtained while pressed against a transparent optical glass plate under the action of 0.5-24 N force and stretching naturally from 90° flexion to 180° full extension respectively. The obtained OCT images showed the deformation results beneath the skin surface, however, DIC images gave overall information of strain at the surface.

  9. AFM imaging and analysis of local mechanical properties for detection of surface pattern of functional groups

    Energy Technology Data Exchange (ETDEWEB)

    Knotek, Petr, E-mail: petr.knotek@upce.cz [University of Pardubice, Faculty of Chemical Technology, Joint Laboratory of Solid State Chemistry of IMC ASCR and University of Pardubice, Studentska 573, 532 10 Pardubice (Czech Republic); Chanova, Eliska; Rypacek, Frantisek [Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic, Heyrovskeho sq. 2, 162 06 Prague (Czech Republic)

    2013-05-01

    In this work we evaluate the applicability of different atomic force microscopy (AFM) modes, such as Phase Shift Imaging, Atomic Force Acoustic Microscopy (AFAM) and Force Spectroscopy, for mapping of the distribution pattern of low-molecular-weight biomimetic groups on polymer biomaterial surfaces. Patterns with either random or clustered spatial distribution of bioactive peptide group derived from fibronectin were prepared by surface deposition of functional block copolymer nano-colloids and grafted with RGDS peptide containing the sequence of amino acids arginine–glycine–aspartic acid–serine (conventionally labeled as RGDS) and carrying biotin as a tag. The biotin-tagged peptides were labeled with 40 nm streptavidin-modified Au nanospheres. The peptide molecules were localized through the detection of bound Au nanospheres by AFM, and thus, the surface distribution of peptides was revealed. AFM techniques capable of monitoring local mechanical properties of the surface were proved to be the most efficient for identification of Au nano-markers. The efficiency was successfully demonstrated on two different patterns, i.e. random and clustered distribution of RGDS peptides on structured surface of the polymer biomaterial. Highlights: ► Bioactive peptides for cell adhesion on PLA-b-PEO biomimetic surface were visualized. ► The biotin-tagged RGDS peptides were labeled with streptavidin-Au nanospheres. ► The RGDS pattern was detected using different atomic force microscopy (AFM) modes. ► Phase Shift Image was proved to be suitable method for studying peptide distribution.

  10. Imaging the pathoanatomy of amyotrophic lateral sclerosis in vivo: targeting a propagation-based biological marker.

    Science.gov (United States)

    Kassubek, Jan; Müller, Hans-Peter; Del Tredici, Kelly; Lulé, Dorothée; Gorges, Martin; Braak, Heiko; Ludolph, Albert C

    2018-04-01

    Neuropathological studies in amyotrophic lateral sclerosis (ALS) have shown a dissemination in a regional sequence in four anatomically defined patterns. The aim of this retrospective study was to see whether longitudinal diffusion tensor imaging (DTI) data support the pathological findings. The application of DTI analysis to fibre structures that are prone to be involved at each neuropathological pattern of ALS was performed in a monocentre sample of 67 patients with ALS and 31 controls that obtained at least one follow-up scan after a median of 6 months. At the group level, longitudinal ALS data showed significant differences for the stage-related tract systems. At the individual level, 27% of the longitudinally scanned patients with ALS showed an increase in ALS stage, while the remaining were stable or were at the highest ALS stage. Longitudinal fractional anisotropy changes in the respective tract systems correlated significantly with the slope of the revised ALS functional rating scale. The DTI-based protocol was able to image the disease patterns of ALS in vivo cross-sectionally and longitudinally, in support of DTI as a technical marker to image ALS stages. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  11. Fractal Image Coding Based on a Fitting Surface

    Directory of Open Access Journals (Sweden)

    Sheng Bi

    2014-01-01

    Full Text Available A no-search fractal image coding method based on a fitting surface is proposed. In our research, an improved gray-level transform with a fitting surface is introduced. One advantage of this method is that the fitting surface is used for both the range and domain blocks and one set of parameters can be saved. Another advantage is that the fitting surface can approximate the range and domain blocks better than the previous fitting planes; this can result in smaller block matching errors and better decoded image quality. Since the no-search and quadtree techniques are adopted, smaller matching errors also imply less number of blocks matching which results in a faster encoding process. Moreover, by combining all the fitting surfaces, a fitting surface image (FSI is also proposed to speed up the fractal decoding. Experiments show that our proposed method can yield superior performance over the other three methods. Relative to range-averaged image, FSI can provide faster fractal decoding process. Finally, by combining the proposed fractal coding method with JPEG, a hybrid coding method is designed which can provide higher PSNR than JPEG while maintaining the same Bpp.

  12. In-Situ Imaging and Quantification of Tritium Surface Contamination via Coherent Fiber Bundle

    International Nuclear Information System (INIS)

    Gentile, Charles A.; Parker, John J.; Zweben, Stewart J.

    2001-01-01

    Princeton Plasma Physics Laboratory (PPPL) has developed a method of imaging tritium on in-situ surfaces for the purpose of real-time data collection. This method expands upon a previous tritium imaging concept, also developed at PPPL. Enhancements include an objective lens coupled to the entry aperture of a coherent fiber optic (CFO) bundle, and a relay lens connecting the exit aperture of the fiber bundle to an intensifier tube and a charge-coupled device (CCD) camera. The system has been specifically fabricated for use in determining tritium concentrations on first wall materials. One potential complication associated with the development of D-T [deuterium-tritium] fueled fusion reactors is the deposition of tritium (i.e., co-deposited layer) on the surface of the primary wall of the vacuum vessel. It would be advantageous to implement a process to accurately determine tritium distribution on these inner surfaces. This fiber optic imaging device provides a highly practical method for determining the location, concentration, and activity of surface tritium deposition. In addition, it can be employed for detection of tritium ''hot-spots'' and ''hide-out'' regions present on the surfaces being imaged

  13. On the use of EPID-based implanted marker tracking for 4D radiotherapy

    International Nuclear Information System (INIS)

    Keall, P.J.; Todor, A.D.; Vedam, S.S.; Bartee, C.L.; Siebers, J.V.; Kini, V.R.; Mohan, R.

    2004-01-01

    Four-dimensional (4D) radiotherapy delivery to dynamically moving tumors requires a real-time signal of the tumor position as a function of time so that the radiation beam can continuously track the tumor during the respiration cycle. The aim of this study was to develop and evaluate an electronic portal imaging device (EPID)-based marker-tracking system that can be used for real-time tumor targeting, or 4D radiotherapy. Three gold cylinders, 3 mm in length and 1 mm in diameter, were implanted in a dynamic lung phantom. The phantom range of motion was 4 cm with a 3-s 'breathing' period. EPID image acquisition parameters were modified, allowing image acquisition in 0.1 s. Images of the stationary and moving phantom were acquired. Software was developed to segment automatically the marker positions from the EPID images. Images acquired in 0.1 s displayed higher noise and a lower signal-noise ratio than those obtained using regular (>1 s) acquisition settings. However, the markers were still clearly visible on the 0.1-s images. The motion of the phantom blurred the images of the markers and further reduced the signal-noise ratio, though they could still be successfully segmented from the images in 10-30 ms of computation time. The positions of gold markers placed in the lung phantom were detected successfully, even for phantom velocities substantially higher than those observed for typical lung tumors. This study shows that using EPID-based marker tracking for 4D radiotherapy is feasible, however, changes in linear accelerator technology and EPID-based image acquisition as well as patient studies are required before this method can be implemented clinically

  14. Transarterial Fiducial Marker Placement for Image-guided Proton Therapy for Malignant Liver Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Ohta, Kengo, E-mail: yesterday.is.yesterday@gmail.com; Shimohira, Masashi, E-mail: mshimohira@gmail.com [Nagoya City University Graduate School of Medical Sciences, Department of Radiology (Japan); Sasaki, Shigeru, E-mail: ssasaki916@yahoo.co.jp; Iwata, Hiromitsu, E-mail: h-iwa-ncu@nifty.com; Nishikawa, Hiroko, E-mail: piroko1018@gmail.com; Ogino, Hiroyuki, E-mail: oginogio@gmail.com; Hara, Masaki, E-mail: mhara@med.nagoya-cu.ac.jp [Nagoya City West Medical Center, Department of Radiation Oncology, Nagoya Proton Therapy Center (Japan); Hashizume, Takuya, E-mail: tky300@gmail.com; Shibamoto, Yuta, E-mail: yshiba@med.nagoya-cu.ac.jp [Nagoya City University Graduate School of Medical Sciences, Department of Radiology (Japan)

    2015-10-15

    PurposeThe aim of this study is to analyze the technical and clinical success rates and safety of transarterial fiducial marker placement for image-guided proton therapy for malignant liver tumors.Methods and MaterialsFifty-five patients underwent this procedure as an interventional treatment. Five patients had 2 tumors, and 4 tumors required 2 markers each, so the total number of procedures was 64. The 60 tumors consisted of 46 hepatocellular carcinomas and 14 liver metastases. Five-mm-long straight microcoils of 0.018 inches in diameter were used as fiducial markers and placed in appropriate positions for each tumor. We assessed the technical and clinical success rates of transarterial fiducial marker placement, as well as the complications associated with it. Technical success was defined as the successful delivery and placement of the fiducial coil, and clinical success was defined as the completion of proton therapy.ResultsAll 64 fiducial coils were successfully installed, so the technical success rate was 100 % (64/64). Fifty-four patients underwent proton therapy without coil migration. In one patient, proton therapy was not performed because of obstructive jaundice due to bile duct invasion by hepatocellular carcinoma. Thus, the clinical success rate was 98 % (54/55). Slight bleeding was observed in one case, but it was stopped immediately and then observed. None of the patients developed hepatic infarctions due to fiducial marker migration.ConclusionTransarterial fiducial marker placement appears to be a useful and safe procedure for proton therapy for malignant liver tumors.

  15. Transarterial Fiducial Marker Placement for Image-guided Proton Therapy for Malignant Liver Tumors

    International Nuclear Information System (INIS)

    Ohta, Kengo; Shimohira, Masashi; Sasaki, Shigeru; Iwata, Hiromitsu; Nishikawa, Hiroko; Ogino, Hiroyuki; Hara, Masaki; Hashizume, Takuya; Shibamoto, Yuta

    2015-01-01

    PurposeThe aim of this study is to analyze the technical and clinical success rates and safety of transarterial fiducial marker placement for image-guided proton therapy for malignant liver tumors.Methods and MaterialsFifty-five patients underwent this procedure as an interventional treatment. Five patients had 2 tumors, and 4 tumors required 2 markers each, so the total number of procedures was 64. The 60 tumors consisted of 46 hepatocellular carcinomas and 14 liver metastases. Five-mm-long straight microcoils of 0.018 inches in diameter were used as fiducial markers and placed in appropriate positions for each tumor. We assessed the technical and clinical success rates of transarterial fiducial marker placement, as well as the complications associated with it. Technical success was defined as the successful delivery and placement of the fiducial coil, and clinical success was defined as the completion of proton therapy.ResultsAll 64 fiducial coils were successfully installed, so the technical success rate was 100 % (64/64). Fifty-four patients underwent proton therapy without coil migration. In one patient, proton therapy was not performed because of obstructive jaundice due to bile duct invasion by hepatocellular carcinoma. Thus, the clinical success rate was 98 % (54/55). Slight bleeding was observed in one case, but it was stopped immediately and then observed. None of the patients developed hepatic infarctions due to fiducial marker migration.ConclusionTransarterial fiducial marker placement appears to be a useful and safe procedure for proton therapy for malignant liver tumors

  16. Multielement surface plasmon resonance immunosensor for monitoring of blood circulation system

    Science.gov (United States)

    Kostyukevych, Sergey A.; Kostyukevych, Kateryna V.; Khristosenko, Roman V.; Lysiuk, Viktor O.; Koptyukh, Anastasiya A.; Moscalenko, Nadiya L.

    2017-12-01

    The problems related to the development of a multielement immunosensor device with the prism type of excitation of a surface plasmon resonance in the Kretschmann configuration and with the scanning of the incidence angle of monochromatic light aimed at the reliable determination of the levels of three molecular markers of the system of hemostasis (fibrinogen, soluble fibrin, and D-dimer) are considered. We have analyzed the influence of a technology for the production of a gold coating, modification of its surface, and noise effects on the enhancement of sensitivity and stability of the operation of devices. A means of oriented immobilization of monoclonal antibodies on the surface of gold using a multilayer film of copper aminopentacyanoferrate is developed. For the model proteins of studied markers, the calibrating curves (maximum sensitivity of 0.5 μg/ml) are obtained, and the level of fibrinogen in blood plasma of donors is determined. A four-channel modification of the device with an application of a reference channel for comparing the elimination of the noise of temperature fluctuations has been constructed. This device allows one to execute the express-diagnostics of prethrombotic states and the monitoring of the therapy of diseases of the blood circulation system.

  17. The use of consumer depth cameras for 3D surface imaging of people with obesity: A feasibility study.

    Science.gov (United States)

    Wheat, J S; Clarkson, S; Flint, S W; Simpson, C; Broom, D R

    2018-05-21

    Three dimensional (3D) surface imaging is a viable alternative to traditional body morphology measures, but the feasibility of using this technique with people with obesity has not been fully established. Therefore, the aim of this study was to investigate the validity, repeatability and acceptability of a consumer depth camera 3D surface imaging system in imaging people with obesity. The concurrent validity of the depth camera based system was investigated by comparing measures of mid-trunk volume to a gold-standard. The repeatability and acceptability of the depth camera system was assessed in people with obesity at a clinic. There was evidence of a fixed systematic difference between the depth camera system and the gold standard but excellent correlation between volume estimates (r 2 =0.997), with little evidence of proportional bias. The depth camera system was highly repeatable - low typical error (0.192L), high intraclass correlation coefficient (>0.999) and low technical error of measurement (0.64%). Depth camera based 3D surface imaging was also acceptable to people with obesity. It is feasible (valid, repeatable and acceptable) to use a low cost, flexible 3D surface imaging system to monitor the body size and shape of people with obesity in a clinical setting. Copyright © 2018 Asia Oceania Association for the Study of Obesity. Published by Elsevier Ltd. All rights reserved.

  18. The Cell Surface Markers Expression in Postmenopausal Women and Relation to Obesity and Bone Status.

    Science.gov (United States)

    Horváthová, Mira; Ilavská, Silvia; Štefíková, Kornélia; Szabová, Michaela; Krivošíková, Zora; Jahnová, Eva; Tulinská, Jana; Spustová, Viera; Gajdoš, Martin

    2017-07-11

    The age-related changes and hormonal deprivation in postmenopausal women are associated with the immune response alteration. The excessive fat accumulation, local and systemic inflammation may lead to dysregulation in immune function and relevant health problems, including obesity and osteoporosis. We analyzed the expression of cell surface markers in the venous blood specimens, stained with fluorophores-conjugated monoclonal antibodies and analysed by multicolour flow cytometry. The significant changes of cytotoxic, naive, and memory T-lymphocytes, plasmacytoid dendritic cells (DCs) were in postmenopausal women versus fertile women. Body mass index (BMI) affected markedly the cell surface expression of CD265/RANK. Osteoporosis is linked to reduced percentage of plasmacytoid DCs, and elevated natural Treg cells ( p < 0.05). The confounding factors such as women age, BMI, bone mineral density (BMD), waist size and tissue fat affect the expression of RANK on myeloid DCs and CD40L on T-lymphocytes that might be the immunophenotypic modulators after menopause.

  19. The Cell Surface Markers Expression in Postmenopausal Women and Relation to Obesity and Bone Status

    Directory of Open Access Journals (Sweden)

    Mira Horváthová

    2017-07-01

    Full Text Available The age-related changes and hormonal deprivation in postmenopausal women are associated with the immune response alteration. The excessive fat accumulation, local and systemic inflammation may lead to dysregulation in immune function and relevant health problems, including obesity and osteoporosis. We analyzed the expression of cell surface markers in the venous blood specimens, stained with fluorophores-conjugated monoclonal antibodies and analysed by multicolour flow cytometry. The significant changes of cytotoxic, naive, and memory T-lymphocytes, plasmacytoid dendritic cells (DCs were in postmenopausal women versus fertile women. Body mass index (BMI affected markedly the cell surface expression of CD265/RANK. Osteoporosis is linked to reduced percentage of plasmacytoid DCs, and elevated natural Treg cells (p < 0.05. The confounding factors such as women age, BMI, bone mineral density (BMD, waist size and tissue fat affect the expression of RANK on myeloid DCs and CD40L on T-lymphocytes that might be the immunophenotypic modulators after menopause.

  20. Augmented reality based real-time subcutaneous vein imaging system.

    Science.gov (United States)

    Ai, Danni; Yang, Jian; Fan, Jingfan; Zhao, Yitian; Song, Xianzheng; Shen, Jianbing; Shao, Ling; Wang, Yongtian

    2016-07-01

    A novel 3D reconstruction and fast imaging system for subcutaneous veins by augmented reality is presented. The study was performed to reduce the failure rate and time required in intravenous injection by providing augmented vein structures that back-project superimposed veins on the skin surface of the hand. Images of the subcutaneous vein are captured by two industrial cameras with extra reflective near-infrared lights. The veins are then segmented by a multiple-feature clustering method. Vein structures captured by the two cameras are matched and reconstructed based on the epipolar constraint and homographic property. The skin surface is reconstructed by active structured light with spatial encoding values and fusion displayed with the reconstructed vein. The vein and skin surface are both reconstructed in the 3D space. Results show that the structures can be precisely back-projected to the back of the hand for further augmented display and visualization. The overall system performance is evaluated in terms of vein segmentation, accuracy of vein matching, feature points distance error, duration times, accuracy of skin reconstruction, and augmented display. All experiments are validated with sets of real vein data. The imaging and augmented system produces good imaging and augmented reality results with high speed.

  1. Visual tritium imaging of In-Vessel surfaces

    International Nuclear Information System (INIS)

    Gentile, C. A.; Zweben, S. J.; Skinner, C. H.; Young, K. M.; Langish, S. W.; Nishi, M. F.; Shu, W. M.; Parker, J.; Isobe, K.

    2000-01-01

    A imaging detector has been developed for the purpose of providing a non-destructive, real time method of determining tritium concentrations on the surface of internal TFTR vacuum vessel components. The detector employs a green phosphor screen (P31, zinc sulfide: copper) with a wave length peak of 530 nm, a charge-coupled device (CCD) camera linked to a computer, and a detection chamber for inserting components recovered from the vacuum vessel. This detector is capable of determining tritium concentrations on the surfaces. The detector provides a method of imaging tritium deposition on the surfaces in a fairly rapid fashion

  2. Visual tritium imaging of in-vessel surfaces

    International Nuclear Information System (INIS)

    Gentile, C.A.; Zweben, S.J.; Skinner, C.H.; Young, K.M.; Langish, S.W.; Nishi, M.F.; Shu, W.M.; Parker, J.; Isobe, K.

    2000-01-01

    An imaging detector has been developed for the purpose of providing a non-destructive, real time method of determining tritium concentrations on the surface of internal TFTR vacuum vessel components. The detector employs a green phosphor screen (P31, zinc sulfide: copper) with a wave length peak of 530 nm, a charge-coupled device (CCD) camera linked to a computer, and a detection chamber for inserting components recovered from the vacuum vessel. This detector is capable of determining tritium concentrations on the surfaces. The detector provides a method of imaging tritium deposition on the surfaces in a fairly rapid fashion

  3. In-situ Planetary Subsurface Imaging System

    Science.gov (United States)

    Song, W.; Weber, R. C.; Dimech, J. L.; Kedar, S.; Neal, C. R.; Siegler, M.

    2017-12-01

    Geophysical and seismic instruments are considered the most effective tools for studying the detailed global structures of planetary interiors. A planet's interior bears the geochemical markers of its evolutionary history, as well as its present state of activity, which has direct implications to habitability. On Earth, subsurface imaging often involves massive data collection from hundreds to thousands of geophysical sensors (seismic, acoustic, etc) followed by transfer by hard links or wirelessly to a central location for post processing and computing, which will not be possible in planetary environments due to imposed mission constraints on mass, power, and bandwidth. Emerging opportunities for geophysical exploration of the solar system from Venus to the icy Ocean Worlds of Jupiter and Saturn dictate that subsurface imaging of the deep interior will require substantial data reduction and processing in-situ. The Real-time In-situ Subsurface Imaging (RISI) technology is a mesh network that senses and processes geophysical signals. Instead of data collection then post processing, the mesh network performs the distributed data processing and computing in-situ, and generates an evolving 3D subsurface image in real-time that can be transmitted under bandwidth and resource constraints. Seismic imaging algorithms (including traveltime tomography, ambient noise imaging, and microseismic imaging) have been successfully developed and validated using both synthetic and real-world terrestrial seismic data sets. The prototype hardware system has been implemented and can be extended as a general field instrumentation platform tailored specifically for a wide variety of planetary uses, including crustal mapping, ice and ocean structure, and geothermal systems. The team is applying the RISI technology to real off-world seismic datasets. For example, the Lunar Seismic Profiling Experiment (LSPE) deployed during the Apollo 17 Moon mission consisted of four geophone instruments

  4. Imaging near-surface heterogeneities by natural migration of surface waves

    KAUST Repository

    Liu, Zhaolun

    2016-09-06

    We demonstrate that near-surface heterogeneities can be imaged by natural migration of backscattered surface waves in common shot gathers. No velocity model is required because the data are migrated onto surface points with the virtual Green\\'s functions computed from the shot gathers. Migrating shot gathers recorded by 2D and 3D land surveys validates the effectiveness of detecting nearsurface heterogeneities by natural migration. The implication is that more accurate hazard maps can be created by migrating surface waves in land surveys.

  5. Method for Surface Scanning in Medical Imaging and Related Apparatus

    DEFF Research Database (Denmark)

    2015-01-01

    A method and apparatus for surface scanning in medical imaging is provided. The surface scanning apparatus comprises an image source, a first optical fiber bundle comprising first optical fibers having proximal ends and distal ends, and a first optical coupler for coupling an image from the image...

  6. Endothelial cell labeling with indium-111-oxine as a marker of cell attachment to bioprosthetic surfaces

    International Nuclear Information System (INIS)

    Sharefkin, J.B.; Lather, C.; Smith, M.; Rich, N.M.

    1983-01-01

    Canine vascular endothelium labeled with indium-111-oxine was used as a marker of cell attachment to vascular prosthetic surfaces with complex textures. Primarily cultured and freshly harvested endothelial cells both took up the label rapidly. An average of 72% of a 32 micro Ci labeling dose was taken up by 1.5 X 10(6) cells in 10 min in serum-free medium. Over 95% of freshly labeled cells were viable by trypan blue tests and only 5% of the label was released after 1 h incubations at 37 degrees C. Labeled and unlabeled cells had similar rates of attachment to plastic dishes. Scanning electron microscopic studies showed that labeled cells retained their ability to spread on tissue culture dishes even at low (1%) serum levels. Labeled endothelial cells seeded onto Dacron or expanded polytetrafluoroethylene vascular prostheses by methods used in current surgical models could be identified by autoradiography of microscopic sections of the prostheses, and the efficiency of cell attachment to the prosthesis could be measured by gamma counting. Indium-111 labeling affords a simple and rapid way to measure initial cell attachment to, and distribution on, vascular prosthetic materials. The method could also allow measurement of early cell loss from a flow surface in vivo by using external gamma imaging

  7. Shimadzu magnetic resonance imaging system, SMT-50

    International Nuclear Information System (INIS)

    Oikawa, Shiro; Nishida, Takayuki; Fujio, Yasuo

    1986-01-01

    The magnetic resonance imaging (MRI) system, as a new modality of medical imaging, has already been put to practical applications on many clinical sites, through which a lot of clinical data has been accumulated. It can offer a powerful new probe of internal anatomy of the human body and its functions. Now that the MRI has established its effectiveness in diagnosis, a really practical MRI system which features high efficiency and economical design with high patient throughput is strongly called for. Introduced in this article is a superconductive magnet MRI system, SMT-50, operating at 5000 Gauss. It has realized an excellent diagnostic capability with such functions as multi-slice multi-echo imaging, high sensitive, surface coil technique and so on. High resolution image display (1024 x 1024 pixcel) unit and separate console system (viewing console and scanning console) will assist high patient throughput. The outline of the SMT-50 and its clinical data are reported here. (author)

  8. Ultrasonography as an ancillary method for the positioning of markers in equine motion analysis

    Directory of Open Access Journals (Sweden)

    Luanna Ferreira Fasanelo Gomes

    2014-08-01

    Full Text Available Kinematic motion analysis is based on the reconstruction of selected bony anatomical landmarks identified by surface markers. Anatomical landmarks generally do not correspond to points but rather to relatively large and curved areas and their identification by palpation is not easy. Precise placement of surface markers is even more difficult and there is great variability between operators. In this study 16 examiners were asked to identify the lateral border of the left ischial tuberosity in a horse using palpation and ultrasonography for placement of a corresponding skin surface marker. Images of each marking procedure were captured using two video cameras and processed using the DVideow videogrammetry. A custom-written Matlab code was used to determine the position of the respective vectors. The positions of the markers were then compared to assess inter-examiner variability and the precision of the methods employed using the Bartletttest and the paired t-test respectively. Ultrasonography significantly improved the location of the anatomical landmark by each examiner (p = 0.04 and reduced the variability in the position of the surface marker when compared to palpation (p = 0.0028. The variability of the calculated distances (mean ± SD was 2.89 ± 2.24 cm and 1.63 ± 0.98 cm using palpation and ultrasonography respectively. Ultrasound guidance reduced inter-examiner variability and allowed visualization of the corresponding bony anatomical landmark.

  9. Multi-slice ultrasound image calibration of an intelligent skin-marker for soft tissue artefact compensation.

    Science.gov (United States)

    Masum, M A; Pickering, M R; Lambert, A J; Scarvell, J M; Smith, P N

    2017-09-06

    In this paper, a novel multi-slice ultrasound (US) image calibration of an intelligent skin-marker used for soft tissue artefact compensation is proposed to align and orient image slices in an exact H-shaped pattern. Multi-slice calibration is complex, however, in the proposed method, a phantom based visual alignment followed by transform parameters estimation greatly reduces the complexity and provides sufficient accuracy. In this approach, the Hough Transform (HT) is used to further enhance the image features which originate from the image feature enhancing elements integrated into the physical phantom model, thus reducing feature detection uncertainty. In this framework, slice by slice image alignment and calibration are carried out and this provides manual ease and convenience. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Is the planum temporale surface area a marker of hemispheric or regional language lateralization?

    Science.gov (United States)

    Tzourio-Mazoyer, Nathalie; Crivello, Fabrice; Mazoyer, Bernard

    2018-04-01

    We investigated the association between the left planum temporale (PT) surface area or asymmetry and the hemispheric or regional functional asymmetries during language production and perception tasks in 287 healthy adults (BIL&GIN) who were matched for sex and handedness. The measurements of the PT surface area were performed after manually delineating the region using brain magnetic resonance images (MRI) and considering the Heschl's gyrus (HG) duplication pattern; the measurements either included (PT tot ) or did not include (PT post ) the second gyrus. A region encompassing both the PT and HG (HGPT) was also studied. Regardless of the ROI measured, 80% of the sample had a positive left minus right PT asymmetry. We first tested whether the PT tot , PT post and HGPT surface areas in the left or right hemispheres or PT asymmetries differed in groups of individuals varying in language lateralization by assessing their hemispheric index during a sentence production minus word list production task. We then investigated the association between these different measures of the PT anatomy and the regional asymmetries measured during the task. Regardless of the anatomical definition used, we observed no correlations between the left surface areas or asymmetries and the hemispheric or regional functional asymmetries during the language production task. We then performed a similar analysis using the same sample measuring language functional lateralization during speech listening tasks (i.e., listening to sentences and lists of words). Although the hemispheric lateralization during speech listening was not correlated with the left PT tot , PT post or HGPT surface areas or the PT asymmetries, significant positive correlations were observed between the asymmetries in these regions and the regional functional asymmetries measured in areas adjacent to the end of the Sylvian fissure while participants listened to the word lists or sentences. The PT asymmetry thus appears to be

  11. Exploring a new quantitative image marker to assess benefit of chemotherapy to ovarian cancer patients

    Science.gov (United States)

    Mirniaharikandehei, Seyedehnafiseh; Patil, Omkar; Aghaei, Faranak; Wang, Yunzhi; Zheng, Bin

    2017-03-01

    Accurately assessing the potential benefit of chemotherapy to cancer patients is an important prerequisite to developing precision medicine in cancer treatment. The previous study has shown that total psoas area (TPA) measured on preoperative cross-section CT image might be a good image marker to predict long-term outcome of pancreatic cancer patients after surgery. However, accurate and automated segmentation of TPA from the CT image is difficult due to the fuzzy boundary or connection of TPA to other muscle areas. In this study, we developed a new interactive computer-aided detection (ICAD) scheme aiming to segment TPA from the abdominal CT images more accurately and assess the feasibility of using this new quantitative image marker to predict the benefit of ovarian cancer patients receiving Bevacizumab-based chemotherapy. ICAD scheme was applied to identify a CT image slice of interest, which is located at the level of L3 (vertebral spines). The cross-sections of the right and left TPA are segmented using a set of adaptively adjusted boundary conditions. TPA is then quantitatively measured. In addition, recent studies have investigated that muscle radiation attenuation which reflects fat deposition in the tissue might be a good image feature for predicting the survival rate of cancer patients. The scheme and TPA measurement task were applied to a large national clinical trial database involving 1,247 ovarian cancer patients. By comparing with manual segmentation results, we found that ICAD scheme could yield higher accuracy and consistency for this task. Using a new ICAD scheme can provide clinical researchers a useful tool to more efficiently and accurately extract TPA as well as muscle radiation attenuation as new image makers, and allow them to investigate the discriminatory power of it to predict progression-free survival and/or overall survival of the cancer patients before and after taking chemotherapy.

  12. Markerless 3D Head Tracking for Motion Correction in High Resolution PET Brain Imaging

    DEFF Research Database (Denmark)

    Olesen, Oline Vinter

    relying on markers. Data-driven motion correction is problematic due to the physiological dynamics. Marker-based tracking is potentially unreliable, and it is extremely hard to validate when the tracking information is correct. The motion estimation is essential for proper motion correction of the PET......This thesis concerns application specific 3D head tracking. The purpose is to improve motion correction in position emission tomography (PET) brain imaging through development of markerless tracking. Currently, motion correction strategies are based on either the PET data itself or tracking devices...... images. Incorrect motion correction can in the worst cases result in wrong diagnosis or treatment. The evolution of a markerless custom-made structured light 3D surface tracking system is presented. The system is targeted at state-of-the-art high resolution dedicated brain PET scanners with a resolution...

  13. Transmission imaging for registration of ictal and interictal single-photon emission tomography, magnetic resonance imaging and electroencephalography

    Energy Technology Data Exchange (ETDEWEB)

    Sipilae, O. [Epilepsy Unit, Neurology, Hospital for Children and Adolescents, Helsinki University Central Hospital (Finland); Laboratory of Biomedical Engineering, Helsinki University of Technology, P.O. Box 2200, FIN-02015 HUT (Finland); Nikkinen, P.; Liewendahl, K. [Division of Nuclear Medicine, Laboratory Department, Helsinki University Central Hospital (Finland); Savolainen, S. [Division of Nuclear Medicine, Laboratory Department, Helsinki University Central Hospital (Finland); Department of Radiology, Helsinki University Central Hospital (Finland); Granstroem, M.-L.; Gaily, E. [Epilepsy Unit, Neurology, Hospital for Children and Adolescents, Helsinki University Central Hospital (Finland); Poutanen, V.-P. [Department of Radiology, Helsinki University Central Hospital (Finland); Pohjonen, H. [Technology Development Centre, P.O. Box 69, 00101 Helsinki (Finland)

    2000-02-01

    A method developed for registration of ictal and interictal single-photon emission tomography (SPET), magnetic resonance imaging (MRI) and electroencephalography (EEG) is described. For SPET studies, technetium-99m ethyl cysteinate dimer (ECD) was injected intravenously while the patient was monitored on video-EEG to document the ictal or interictal state. Imaging was performed using a triple-head gamma camera equipped with a transmission imaging device using a gadolinium-153 source. The images (128 x 128 pixels, voxel size 3.7 x 3.7 x 3.6 mm{sup 3}) were reconstructed using an iterative algorithm and postfiltered with a Wiener filter. The gold-plated silver electrodes on the patient's scalp were utilized as markers for registration of the ictal and interictal SPET images, as these metallic markers were clearly seen on the transmission images. Fitting of the marker sets was based on a non-iterative least squares method. The interictal SPET image was subtracted from the ictal image after scaling. The T1-weighted MPRAGE MR images with voxel size of 1.0 x 1.0 x 1.0 mm{sup 3} were obtained with a 1.5-T scanner. For registration of MR and subtraction SPET images, the external marker set of the ictal SPET study was fitted to the surface of the head segmented from MR images. The SPET registration was tested with a phantom experiment. Registration of ictal and interictal SPET in five patient studies resulted in a 2-mm RMS residual of the marker sets. The estimated RMS error of registration in the final result combining locations of the electrodes, subtraction SPET and MR images was 3-5 mm. In conclusion, transmission imaging can be utilized for an accurate and easily implemented registration procedure for ictal and interictal SPET, MRI and EEG. (orig.)

  14. Multilayer X-ray imaging systems

    Science.gov (United States)

    Shealy, D. L.; Hoover, R. B.; Gabardi, D. R.

    1986-01-01

    An assessment of the imaging properties of multilayer X-ray imaging systems with spherical surfaces has been made. A ray trace analysis was performed to investigate the effects of using spherical substrates (rather than the conventional paraboloidal/hyperboloidal contours) for doubly reflecting Cassegrain telescopes. These investigations were carried out for mirrors designed to operate at selected soft X-ray/XUV wavelengths that are of significance for studies of the solar corona/transition region from the Stanford/MSFC Rocket X-Ray Telescope. The effects of changes in separation of the primary and secondary elements were also investigated. These theoretical results are presented as well as the results of ray trace studies to establish the resolution and vignetting effects as a function of field angle and system parameters.

  15. Four-channel surface coil array for sequential CW-EPR image acquisition

    Science.gov (United States)

    Enomoto, Ayano; Emoto, Miho; Fujii, Hirotada; Hirata, Hiroshi

    2013-09-01

    This article describes a four-channel surface coil array to increase the area of visualization for continuous-wave electron paramagnetic resonance (CW-EPR) imaging. A 776-MHz surface coil array was constructed with four independent surface coil resonators and three kinds of switches. Control circuits for switching the resonators were also built to sequentially perform EPR image acquisition for each resonator. The resonance frequencies of the resonators were shifted using PIN diode switches to decouple the inductively coupled coils. To investigate the area of visualization with the surface coil array, three-dimensional EPR imaging was performed using a glass cell phantom filled with a solution of nitroxyl radicals. The area of visualization obtained with the surface coil array was increased approximately 3.5-fold in comparison to that with a single surface coil resonator. Furthermore, to demonstrate the applicability of this surface coil array to animal imaging, three-dimensional EPR imaging was performed in a living mouse with an exogenously injected nitroxyl radical imaging agent.

  16. Evaluation of the AN/SAY-1 Thermal Imaging Sensor System

    National Research Council Canada - National Science Library

    Smith, John G; Middlebrook, Christopher T

    2002-01-01

    The AN/SAY-1 Thermal Imaging Sensor System "TISS" was developed to provide surface ships with a day/night imaging capability to detect low radar reflective, small cross-sectional area targets such as floating mines...

  17. Digital detection system of surface defects for large aperture optical elements

    International Nuclear Information System (INIS)

    Fan Yong; Chen Niannian; Gao Lingling; Jia Yuan; Wang Junbo; Cheng Xiaofeng

    2009-01-01

    Based on the light defect images against the dark background in a scattering imaging system, a digital detection system of surface defects for large aperture optical elements has been presented. In the system, the image is segmented by a multi-area self-adaptive threshold segmentation method, then a pixel labeling method based on replacing arrays is adopted to extract defect features quickly, and at last the defects are classified through back-propagation neural networks. Experiment results show that the system can achieve real-time detection and classification. (authors)

  18. Defect Detection of Steel Surfaces with Global Adaptive Percentile Thresholding of Gradient Image

    Science.gov (United States)

    Neogi, Nirbhar; Mohanta, Dusmanta K.; Dutta, Pranab K.

    2017-12-01

    Steel strips are used extensively for white goods, auto bodies and other purposes where surface defects are not acceptable. On-line surface inspection systems can effectively detect and classify defects and help in taking corrective actions. For detection of defects use of gradients is very popular in highlighting and subsequently segmenting areas of interest in a surface inspection system. Most of the time, segmentation by a fixed value threshold leads to unsatisfactory results. As defects can be both very small and large in size, segmentation of a gradient image based on percentile thresholding can lead to inadequate or excessive segmentation of defective regions. A global adaptive percentile thresholding of gradient image has been formulated for blister defect and water-deposit (a pseudo defect) in steel strips. The developed method adaptively changes the percentile value used for thresholding depending on the number of pixels above some specific values of gray level of the gradient image. The method is able to segment defective regions selectively preserving the characteristics of defects irrespective of the size of the defects. The developed method performs better than Otsu method of thresholding and an adaptive thresholding method based on local properties.

  19. Medical Imaging System

    Science.gov (United States)

    1991-01-01

    The MD Image System, a true-color image processing system that serves as a diagnostic aid and tool for storage and distribution of images, was developed by Medical Image Management Systems, Huntsville, AL, as a "spinoff from a spinoff." The original spinoff, Geostar 8800, developed by Crystal Image Technologies, Huntsville, incorporates advanced UNIX versions of ELAS (developed by NASA's Earth Resources Laboratory for analysis of Landsat images) for general purpose image processing. The MD Image System is an application of this technology to a medical system that aids in the diagnosis of cancer, and can accept, store and analyze images from other sources such as Magnetic Resonance Imaging.

  20. Simultaneous 3D localization of multiple MR-visible markers in fully reconstructed MR images: proof-of-concept for subsecond position tracking.

    Science.gov (United States)

    Thörmer, Gregor; Garnov, Nikita; Moche, Michael; Haase, Jürgen; Kahn, Thomas; Busse, Harald

    2012-04-01

    To determine whether a greatly reduced spatial resolution of fully reconstructed projection MR images can be used for the simultaneous 3D localization of multiple MR-visible markers and to assess the feasibility of a subsecond position tracking for clinical purposes. Miniature, inductively coupled RF coils were imaged in three orthogonal planes with a balanced steady-state free precession (SSFP) sequence and automatically localized using a two-dimensional template fitting and a subsequent three-dimensional (3D) matching of the coordinates. Precision, accuracy, speed and robustness of 3D localization were assessed for decreasing in-plane resolutions (0.6-4.7 mm). The feasibility of marker tracking was evaluated at the lowest resolution by following a robotically driven needle on a complex 3D trajectory. Average 3D precision and accuracy, sensitivity and specificity of localization ranged between 0.1 and 0.4 mm, 0.5 and 1.0 mm, 100% and 95%, and 100% and 96%, respectively. At the lowest resolution, imaging and localization took ≈350 ms and provided an accuracy of ≈1.0 mm. In the tracking experiment, the needle was clearly depicted on the oblique scan planes defined by the markers. Image-based marker localization at a greatly reduced spatial resolution is considered a feasible approach to monitor reference points or rigid instruments at subsecond update rates. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Tumor markers CEA and CA 19-9 correlate with radiological imaging in metastatic colorectal cancer patients receiving first-line chemotherapy.

    Science.gov (United States)

    Michl, M; Koch, J; Laubender, R P; Modest, D P; Giessen, C; Schulz, Ch; Heinemann, V

    2014-10-01

    In patients with metastatic colorectal cancer (mCRC), radiological imaging represents the current standard to evaluate the efficacy of chemotherapy. However, with growing knowledge about tumor biology, other diagnostic tools become of interest which can supplement radiology. The aim of the present study was to examine the correlation of tumor and serum markers with radiological imaging in patients with mCRC receiving first-line therapy. Patients were included if tumor (carcinoembryonic antigen (CEA), carbohydrate antigen 19-9 (CA 19-9)) and serum marker (lactatdehydrogenase (LDH), γ-glutamyltransferase (γGT), alkaline phosphatase (AP), C-reactive protein (CRP), leucocyte count (WBC), hemoglobin (Hb)) levels were available at baseline and at least two times during treatment. The decline and increase of tumor and serum markers over time were approximated for each patient by estimating slopes depending on the radiological assessment. A linear mixed effects multiple regression model for each subject was used to evaluate the intra-class correlation of these slopes modeling tumor and serum marker changes with radiological imaging. Data of 124 patients (41 female, 83 male; median age 62.9 years, range 27-85) who received first-line chemotherapy for mCRC from 11/2007 to 04/2010 were analyzed retrospectively. CEA level slopes (n = 49; slopes = 102) differed between radiologically determined progressive disease (PD) and partial response (PR) (p = 0.005) and between PD and stable disease (SD) (p = 0.042). CA 19-9 level slopes (n = 57; slopes = 127) also showed a significant difference between PD and PR (p = 0.002) and PD and SD (p = 0.058). Furthermore, CRP slopes (n = 62; slopes = 134) differed significantly between PD and PR (p = 0.009). For LDH, ALP, γGT, Hb, and WBC, no correlations were observed. The results indicate the correlation of the tumor markers CEA, CA 19-9, and the serum marker CRP with radiological imaging in

  2. A Comparison of Soft-Tissue Implanted Markers and Bony Anatomy Alignments for Image-Guided Treatments of Head-and-Neck Cancers

    International Nuclear Information System (INIS)

    Zeidan, Omar A.; Huddleston, Adam J.; Lee, Choonik; Langen, Katja M.; Kupelian, Patrick A.; Meeks, Sanford L.; Manon, Rafael R.

    2010-01-01

    Purpose: To compare the geometric alignments of soft-tissue implanted markers to the traditional bony-based alignments in head-and-neck cancers, on the basis of daily image guidance. Dosimetric impact of the two alignment techniques on target coverage is presented. Methods and Materials: A total of 330 retrospective alignments (5 patients) were performed on daily megavoltage computed tomography (MVCT) image sets using both alignment techniques. Intermarker distances were tracked for all fractions to assess marker interfractional stability. Using a deformable image registration algorithm, target cumulative doses were calculated according to generated shifts on daily MVCT image sets. Target D95 was used as a dosimetric endpoint to evaluate each alignment technique. Results: Intermarker distances overall were stable, with a standard deviation of <1.5 mm for all fractions and no observed temporal trends. Differences in shift magnitudes between both alignment techniques were found to be statistically significant, with a maximum observed difference of 8 mm in a given direction. Evaluation of technique-specific dose coverage based on D95 of target clinical target volume and planning target volume shows small differences (within ±5%) compared with the kilovoltage CT plan. Conclusion: The use of daily MVCT imaging demonstrates that implanted markers in oral tongue and soft-palate cancers are stable localization surrogates. Alignments based on implanted markers generate shifts comparable overall to the traditional bony-based alignment, with no observed systematic difference in magnitude or direction. The cumulative dosimetric impact on target clinical target volume and planning target volume coverage was found to be similar, despite large observed differences in daily alignment shifts between the two techniques.

  3. Image potential resonances of the aluminum (100) surface; Bildpotentialresonanzen der Aluminium-(100)-Oberflaeche

    Energy Technology Data Exchange (ETDEWEB)

    Winter, Matthias

    2011-07-08

    Image-potential resonances on the (100) surface of pure Aluminum are investigated experimentally and theoretically. The experiments are conducted both energy- and time-resolved using the method of two-photon photoemission spectroscopy. The main attention of the theoretical examination and extensive numerical calculations is devoted to the interaction between surface and bulk states. Image-potential resonances on Al(100) are a system in which a complete series of discrete Rydberg states strongly couples to a continuum of states. As a simple metal it also provides a good opportunity to test theoretical models of the structure of the potential at metal surfaces. This work represents the first high-resolution investigation of image-potential resonances with such strong resonance character. For the first time, it is demonstrated experimentally that isolated image-potential resonances exist on an Aluminum surface. On the (100) surface of Aluminum the second through fifth image-potential resonance are resolved and both, their energies and lifetimes are measured. The binding energies of the image-potential resonances form a Rydberg series of states {epsilon}{sub n}=-(0,85 eV)/((n+a){sup 2}). Within the accuracy of the measurement it is not necessary to introduce a quantum defect a (a=0.022{+-}0.035). Using angle-resolved two-photon photoemission spectroscopy the effective mass of electrons in the second image-potential resonance is measured to 1.01{+-}0.11 electron masses. The lifetimes of the resonances increase as {tau}{sub n} = (1.0{+-}0.2)fs.n{sup 3} starting from n=2. Calculations using the density matrix formalism show that the experimentally observed lifetimes can be explained well by electrons decaying into the bulk. The effect of resonance trapping leads to extended lifetimes in the process. Contrary to common theoretical models of image-potential states at metal surfaces the first image-potential resonance cannot be observed in two-photon photoemission on Al(100

  4. Focused surface coil for MR imaging of the pituitary

    International Nuclear Information System (INIS)

    Harms, S.E.; Sherry, C.S.; Youshimura, L.; Lokken, R.; Hyde, J.S.

    1987-01-01

    A specially designed surface coil for pituitary MR imaging results in improved image quality over that achieved with conventional pituitary Mr imaging. The coil consists of connected planar pair coils with a variable intercoil distance to accommodate differences in head size. The sensitive field is focused deep to the surface between the two planar pairs. This arrangement optimizes the signal-to-noise ratio and allows better gradient magnification of the pituitary region. Fifteen subjects with a variety of pituitary disorders were imaged

  5. Fiducial registration error as a statistical process control metric in image-guided radiotherapy with prostatic markers

    International Nuclear Information System (INIS)

    Ung, M.N.; Wee, Leonard

    2010-01-01

    Full text: Portal imaging of implanted fiducial markers has been in use for image-guided radiotherapy (TORT) of prostate cancer, with ample attention to localization accuracy and organ motion. The geometric uncertainties in point-based rigid-body (PBRB) image registration during localization of prostate fiducial markers can be quantified in terms of a fiducial registration error (FRE). Statistical process control charts for individual patients can be designed to identify potentially significant deviation of FRE from expected behaviour. In this study, the aim was to retrospectively apply statistical process control methods to FREs in 34 individuals to identify parameters that may impact on the process stability in image-based localization. A robust procedure for estimating control parameters, control lim its and fixed tolerance levels from a small number of initial observations has been proposed and discussed. Four distinct types of qualitative control chart behavior have been observed. Probable clinical factors leading to IORT process instability are discussed in light of the control chart behaviour. Control charts have been shown to be a useful decision-making tool for detecting potentially out-of control processes on an individual basis. It can sensitively identify potential problems that warrant more detailed investigation in the 10RT of prostate cancer.

  6. Time-dependent image potential at a metal surface

    International Nuclear Information System (INIS)

    Alducin, M.; Diez Muino, R.; Juaristi, J.I.

    2003-01-01

    Transient effects in the image potential induced by a point charge suddenly created in front of a metal surface are studied. The time evolution of the image potential is calculated using linear response theory. Two different time scales are defined: (i) the time required for the creation of the image potential and (ii) the time it takes to converge to its stationary value. Their dependence on the distance of the charge to the surface is discussed. The effect of the electron gas damping is also analyzed. For a typical metallic density, the order of magnitude of the creation time is 0.1 fs, whereas for a charge created close to the surface the convergence time is around 1-2 fs

  7. Relative impact of amyloid-β, lacunes, and downstream imaging markers on cognitive trajectories.

    Science.gov (United States)

    Kim, Hee Jin; Yang, Jin Ju; Kwon, Hunki; Kim, Changsoo; Lee, Jong Min; Chun, Phillip; Kim, Yeo Jin; Jung, Na-Yeon; Chin, Juhee; Kim, Seonwoo; Woo, Sook-Young; Choe, Yearn Seong; Lee, Kyung-Han; Kim, Sung Tae; Kim, Jae Seung; Lee, Jae Hong; Weiner, Michael W; Na, Duk L; Seo, Sang Won

    2016-09-01

    SEE COHEN DOI101093/AWW183 FOR A SCIENTIFIC COMMENTARY ON THIS ARTICLE: Amyloid-β and cerebral small vessel disease are the two major causes of cognitive impairment in the elderly. However, the underlying mechanisms responsible for precisely how amyloid-β and cerebral small vessel disease affect cognitive impairment remain unclear. We investigated the effects of amyloid-β and lacunes on downstream imaging markers including structural network and cortical thickness, further analysing their relative impact on cognitive trajectories. We prospectively recruited a pool of 117 mild cognitive impairment patients (45 amnestic type and 72 subcortical vascular type), from which 83 patients received annual follow-up with neuropsychological tests and brain magnetic resonance imaging for 3 years, and 87 patients received a second Pittsburgh compound B positron emission tomography analysis. Structural networks based on diffusion tensor imaging and cortical thickness were analysed. We used linear mixed effect regression models to evaluate the effects of imaging markers on cognitive decline. Time-varying Pittsburgh compound B uptake was associated with temporoparietal thinning, which correlated with memory decline (verbal memory test, unstandardized β = -0.79, P memory test, unstandardized β = -2.84, P = 0.009). Time-varying lacune number was associated with the degree of frontoparietal network disruption or thinning, which further affected frontal-executive function decline (Digit span backward test, unstandardized β = -0.05, P = 0.002; Stroop colour test, unstandardized β = -0.94, P = 0.008). Of the multiple imaging markers analysed, Pittsburgh compound B uptake and the number of lacunes had the greatest association with memory decline and frontal-executive function decline, respectively: Time-varying Pittsburgh compound B uptake (standardized β = -0.25, P = 0.010) showed the strongest effect on visual memory test, followed by time-varying temporoparietal thickness

  8. Ptychographic x-ray imaging of surfaces on crystal truncation rod

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Chenhui; Barbour, Andi; Liu, Yaohua; You, Hoydoo, E-mail: hyou@anl.gov [Materials Science Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Harder, Ross; Xu, Ruqing [Advanced Photon Source, Argonne National Laboratory, Argonne, Illinois 60439 (United States); Diaz, Ana; Menzel, Andreas [Paul Scherrer Institut, Villigen PSI 5232 (Switzerland); Komanicky, Vladimir [Faculty of Sciences, Safarik University, Kosice 04154 (Slovakia); Huang, Xiaojing [National Synchrotron Light Source II, Brookhaven National Laboratory, Upton, New York 11973 (United States); Pierce, Michael S. [School of Physics and Astronomy, Rochester Institute of Technology, Rochester, New York 14623 (United States)

    2015-03-09

    Ptychography is a high-resolution imaging technique, which does not require lenses for image magnification and which provides phase contrast with high sensitivity. Here, we propose to use x-ray ptychography for the imaging of surface structure in crystalline samples. We show that ptychography can be used to image atomic step structures using coherent diffraction patterns recorded along the crystal truncation rod of a crystal surface. In a proof-of-concept experiment on a Pt (111) sample, we present ptychographic reconstructions showing features consistent with surface steps. Due to the penetration power of x-rays, this method could find interesting applications for the study of surface structures under buried interfaces or in harsh environments.

  9. Ptychographic x-ray imaging of surfaces on crystal truncation rod

    International Nuclear Information System (INIS)

    Zhu, Chenhui; Barbour, Andi; Liu, Yaohua; You, Hoydoo; Harder, Ross; Xu, Ruqing; Diaz, Ana; Menzel, Andreas; Komanicky, Vladimir; Huang, Xiaojing; Pierce, Michael S.

    2015-01-01

    Ptychography is a high-resolution imaging technique, which does not require lenses for image magnification and which provides phase contrast with high sensitivity. Here, we propose to use x-ray ptychography for the imaging of surface structure in crystalline samples. We show that ptychography can be used to image atomic step structures using coherent diffraction patterns recorded along the crystal truncation rod of a crystal surface. In a proof-of-concept experiment on a Pt (111) sample, we present ptychographic reconstructions showing features consistent with surface steps. Due to the penetration power of x-rays, this method could find interesting applications for the study of surface structures under buried interfaces or in harsh environments

  10. Superresolution Near-field Imaging with Surface Waves

    KAUST Repository

    Fu, Lei; Liu, Zhaolun; Schuster, Gerard T.

    2017-01-01

    We present the theory for near-field superresolution imaging with surface waves and time reverse mirrors (TRMs). Theoretical formulas and numerical results show that applying the TRM operation to surface waves in an elastic half-space can achieve

  11. Cost-effective system for facial imaging and three-dimensional reconstruction

    Science.gov (United States)

    Shokouhi, S. B.; Monro, D. M.; Sherlock, Barry G.

    1998-06-01

    Three dimensional (3-D) images have recently received wide attention in applications involving medical treatment. Most current 3-D imaging methods focus on the internal organs of the body. However, several medical image applications such as plastic surgery, body deformities, rehabilitation, dental surgery and orthodontics, make use of the surface contours of the body. Several techniques are currently available for producing 3-D images of the body surface and most of the systems which implement these techniques are expensive, requiring complex equipment with highly trained operators. The research involves the development of a simple, low cost and non-invasive contour capturing method for facial surfaces. This is achieved using the structured light technique, employing a standard commercial slide projector, CCD camera and a frame-grabber card linked to a PC. Structured light has already been used for many applications, but only to a limited extent in the clinical environment. All current implementations involve extensive manual intervention by highly skilled operators and this has proven to be a serious hindrance to clinical acceptance of 3-D imaging. A primary objective of this work is to minimize the amount of manual intervention required, so that the system can be used by clinicians who do not have specialist training in the use of this equipment. The eventual aim is to provide a software assisted surgical procedure, which by merging the facial data, allows the manipulation of soft tissue and gives the facility to predict and monitor post-surgical appearance. The research focuses on how the images are obtained using the structured light optic system and the subsequent image processing of data to give a realistic 3-D image.

  12. Surface inspection system for industrial components based on shape from shading minimization approach

    Science.gov (United States)

    Kotan, Muhammed; Öz, Cemil

    2017-12-01

    An inspection system using estimated three-dimensional (3-D) surface characteristics information to detect and classify the faults to increase the quality control on the frequently used industrial components is proposed. Shape from shading (SFS) is one of the basic and classic 3-D shape recovery problems in computer vision. In our application, we developed a system using Frankot and Chellappa SFS method based on the minimization of the selected basis function. First, the specialized image acquisition system captured the images of the component. To eliminate noise, wavelet transform is applied to the taken images. Then, estimated gradients were used to obtain depth and surface profiles. Depth information was used to determine and classify the surface defects. Also, a comparison made with some linearization-based SFS algorithms was discussed. The developed system was applied to real products and the results indicated that using SFS approaches is useful and various types of defects can easily be detected in a short period of time.

  13. SU-G-JeP1-11: Feasibility Study of Markerless Tracking Using Dual Energy Fluoroscopic Images for Real-Time Tumor-Tracking Radiotherapy System

    Energy Technology Data Exchange (ETDEWEB)

    Shiinoki, T; Shibuya, K [Yamaguchi University, Ube, Yamaguchi (Japan); Sawada, A [Kyoto college of medical science, Nantan, Kyoto (Japan); Uehara, T; Yuasa, Y; Koike, M; Kawamura, S [Yamaguchi University Hospital, Ube, Yamaguchi (Japan)

    2016-06-15

    Purpose: The new real-time tumor-tracking radiotherapy (RTRT) system was installed in our institution. This system consists of two x-ray tubes and color image intensifiers (I.I.s). The fiducial marker which was implanted near the tumor was tracked using color fluoroscopic images. However, the implantation of the fiducial marker is very invasive. Color fluoroscopic images enable to increase the recognition of the tumor. However, these images were not suitable to track the tumor without fiducial marker. The purpose of this study was to investigate the feasibility of markerless tracking using dual energy colored fluoroscopic images for real-time tumor-tracking radiotherapy system. Methods: The colored fluoroscopic images of static and moving phantom that had the simulated tumor (30 mm diameter sphere) were experimentally acquired using the RTRT system. The programmable respiratory motion phantom was driven using the sinusoidal pattern in cranio-caudal direction (Amplitude: 20 mm, Time: 4 s). The x-ray condition was set to 55 kV, 50 mA and 105 kV, 50 mA for low energy and high energy, respectively. Dual energy images were calculated based on the weighted logarithmic subtraction of high and low energy images of RGB images. The usefulness of dual energy imaging for real-time tracking with an automated template image matching algorithm was investigated. Results: Our proposed dual energy subtraction improve the contrast between tumor and background to suppress the bone structure. For static phantom, our results showed that high tracking accuracy using dual energy subtraction images. For moving phantom, our results showed that good tracking accuracy using dual energy subtraction images. However, tracking accuracy was dependent on tumor position, tumor size and x-ray conditions. Conclusion: We indicated that feasibility of markerless tracking using dual energy fluoroscopic images for real-time tumor-tracking radiotherapy system. Furthermore, it is needed to investigate the

  14. High resolution imaging of surface patterns of single bacterial cells

    International Nuclear Information System (INIS)

    Greif, Dominik; Wesner, Daniel; Regtmeier, Jan; Anselmetti, Dario

    2010-01-01

    We systematically studied the origin of surface patterns observed on single Sinorhizobium meliloti bacterial cells by comparing the complementary techniques atomic force microscopy (AFM) and scanning electron microscopy (SEM). Conditions ranged from living bacteria in liquid to fixed bacteria in high vacuum. Stepwise, we applied different sample modifications (fixation, drying, metal coating, etc.) and characterized the observed surface patterns. A detailed analysis revealed that the surface structure with wrinkled protrusions in SEM images were not generated de novo but most likely evolved from similar and naturally present structures on the surface of living bacteria. The influence of osmotic stress to the surface structure of living cells was evaluated and also the contribution of exopolysaccharide and lipopolysaccharide (LPS) by imaging two mutant strains of the bacterium under native conditions. AFM images of living bacteria in culture medium exhibited surface structures of the size of single proteins emphasizing the usefulness of AFM for high resolution cell imaging.

  15. Marker-Based Multi-Sensor Fusion Indoor Localization System for Micro Air Vehicles.

    Science.gov (United States)

    Xing, Boyang; Zhu, Quanmin; Pan, Feng; Feng, Xiaoxue

    2018-05-25

    A novel multi-sensor fusion indoor localization algorithm based on ArUco marker is designed in this paper. The proposed ArUco mapping algorithm can build and correct the map of markers online with Grubbs criterion and K-mean clustering, which avoids the map distortion due to lack of correction. Based on the conception of multi-sensor information fusion, the federated Kalman filter is utilized to synthesize the multi-source information from markers, optical flow, ultrasonic and the inertial sensor, which can obtain a continuous localization result and effectively reduce the position drift due to the long-term loss of markers in pure marker localization. The proposed algorithm can be easily implemented in a hardware of one Raspberry Pi Zero and two STM32 micro controllers produced by STMicroelectronics (Geneva, Switzerland). Thus, a small-size and low-cost marker-based localization system is presented. The experimental results show that the speed estimation result of the proposed system is better than Px4flow, and it has the centimeter accuracy of mapping and positioning. The presented system not only gives satisfying localization precision, but also has the potential to expand other sensors (such as visual odometry, ultra wideband (UWB) beacon and lidar) to further improve the localization performance. The proposed system can be reliably employed in Micro Aerial Vehicle (MAV) visual localization and robotics control.

  16. Marker-Based Multi-Sensor Fusion Indoor Localization System for Micro Air Vehicles

    Directory of Open Access Journals (Sweden)

    Boyang Xing

    2018-05-01

    Full Text Available A novel multi-sensor fusion indoor localization algorithm based on ArUco marker is designed in this paper. The proposed ArUco mapping algorithm can build and correct the map of markers online with Grubbs criterion and K-mean clustering, which avoids the map distortion due to lack of correction. Based on the conception of multi-sensor information fusion, the federated Kalman filter is utilized to synthesize the multi-source information from markers, optical flow, ultrasonic and the inertial sensor, which can obtain a continuous localization result and effectively reduce the position drift due to the long-term loss of markers in pure marker localization. The proposed algorithm can be easily implemented in a hardware of one Raspberry Pi Zero and two STM32 micro controllers produced by STMicroelectronics (Geneva, Switzerland. Thus, a small-size and low-cost marker-based localization system is presented. The experimental results show that the speed estimation result of the proposed system is better than Px4flow, and it has the centimeter accuracy of mapping and positioning. The presented system not only gives satisfying localization precision, but also has the potential to expand other sensors (such as visual odometry, ultra wideband (UWB beacon and lidar to further improve the localization performance. The proposed system can be reliably employed in Micro Aerial Vehicle (MAV visual localization and robotics control.

  17. Multifunctional nanoparticles as a tissue adhesive and an injectable marker for image-guided procedures

    Science.gov (United States)

    Shin, Kwangsoo; Choi, Jin Woo; Ko, Giho; Baik, Seungmin; Kim, Dokyoon; Park, Ok Kyu; Lee, Kyoungbun; Cho, Hye Rim; Han, Sang Ihn; Lee, Soo Hong; Lee, Dong Jun; Lee, Nohyun; Kim, Hyo-Cheol; Hyeon, Taeghwan

    2017-07-01

    Tissue adhesives have emerged as an alternative to sutures and staples for wound closure and reconnection of injured tissues after surgery or trauma. Owing to their convenience and effectiveness, these adhesives have received growing attention particularly in minimally invasive procedures. For safe and accurate applications, tissue adhesives should be detectable via clinical imaging modalities and be highly biocompatible for intracorporeal procedures. However, few adhesives meet all these requirements. Herein, we show that biocompatible tantalum oxide/silica core/shell nanoparticles (TSNs) exhibit not only high contrast effects for real-time imaging but also strong adhesive properties. Furthermore, the biocompatible TSNs cause much less cellular toxicity and less inflammation than a clinically used, imageable tissue adhesive (that is, a mixture of cyanoacrylate and Lipiodol). Because of their multifunctional imaging and adhesive property, the TSNs are successfully applied as a hemostatic adhesive for minimally invasive procedures and as an immobilized marker for image-guided procedures.

  18. Intra-fraction prostate displacement in radiotherapy estimated from pre- and post-treatment imaging of patients with implanted fiducial markers

    International Nuclear Information System (INIS)

    Kron, Tomas; Thomas, Jessica; Fox, Chris; Thompson, Ann; Owen, Rebecca; Herschtal, Alan; Haworth, Annette; Tai, Keen-Hun; Foroudi, Farshad

    2010-01-01

    Purpose: To determine intra-fraction displacement of the prostate gland from imaging pre- and post-radiotherapy delivery of prostate cancer patients with three implanted fiducial markers. Methods and materials: Data were collected from 184 patients who had two orthogonal X-rays pre- and post-delivery on at least 20 occasions using a Varian On Board kV Imaging system. A total of 5778 image pairs covering time intervals between 3 and 30 min between pre- and post-imaging were evaluated for intra-fraction prostate displacement. Results: The mean three dimensional vector shift between images was 1.7 mm ranging from 0 to 25 mm. No preferential direction of displacement was found; however, there was an increase of prostate displacement with time between images. There was a large variation in typical shifts between patients (range 1 ± 1 to 6 ± 2 mm) with no apparent trends throughout the treatment course. Images acquired in the first five fractions of treatment could be used to predict displacement patterns for individual patients. Conclusion: Intra-fraction motion of the prostate gland appears to be a limiting factor when considering margins for radiotherapy. Given the variation between patients, a uniform set of margins for all patients may not be satisfactory when high target doses are to be delivered.

  19. Tablet surface characterisation by various imaging techniques

    DEFF Research Database (Denmark)

    Seitavuopio, Paulus; Rantanen, Jukka; Yliruusi, Jouko

    2003-01-01

    The aim of this study was to characterise tablet surfaces using different imaging and roughness analytical techniques including optical microscopy, scanning electron microscopy (SEM), laser profilometry and atomic force microscopy (AFM). The test materials compressed were potassium chloride (KCl......) and sodium chloride (NaCl). It was found that all methods used suggested that the KCl tablets were smoother than the NaCl tablets and higher compression pressure made the tablets smoother. Imaging methods like optical microscopy and SEM can give useful information about the roughness of the sample surface...

  20. Detection of microbial biofilms on food processing surfaces: Hyperspectral fluorescence imaging study

    Science.gov (United States)

    We used a portable hyperspectral fluorescence imaging system to evaluate biofilm formations on four types of food processing surface materials including stainless steel, polypropylene used for cutting boards, and household counter top materials such as formica and granite. The objective of this inve...

  1. Image statistics and the perception of surface gloss and lightness.

    Science.gov (United States)

    Kim, Juno; Anderson, Barton L

    2010-07-01

    Despite previous data demonstrating the critical importance of 3D surface geometry in the perception of gloss and lightness, I. Motoyoshi, S. Nishida, L. Sharan, and E. H. Adelson (2007) recently proposed that a simple image statistic--histogram or sub-band skew--is computed by the visual system to infer the gloss and albedo of surfaces. One key source of evidence used to support this claim was an experiment in which adaptation to skewed image statistics resulted in opponent aftereffects in observers' judgments of gloss and lightness. We report a series of adaptation experiments that were designed to assess the cause of these aftereffects. We replicated their original aftereffects in gloss but found no consistent aftereffect in lightness. We report that adaptation to zero-skew adaptors produced similar aftereffects as positively skewed adaptors, and that negatively skewed adaptors induced no reliable aftereffects. We further find that the adaptation effect observed with positively skewed adaptors is not robust to changes in mean luminance that diminish the intensity of the luminance extrema. Finally, we show that adaptation to positive skew reduces (rather than increases) the apparent lightness of light pigmentation on non-uniform albedo surfaces. These results challenge the view that the adaptation results reported by Motoyoshi et al. (2007) provide evidence that skew is explicitly computed by the visual system.

  2. Development of an Operational System for the Retrieval of Aerosol and Land Surface Properties from the Terra Multi-Angle Imaging SpectroRadiometer

    Science.gov (United States)

    Crean, Kathleen A.

    2003-01-01

    An operational system to retrieve atmospheric aerosol and land surface properties using data from the Multi-angle Imaging SpectroRadiometer (MISR) instrument, currently flying onboard NASA's Terra spacecraft, has been deployed. The system is in full operation, with new data products generated daily and distributed to science users worldwide. This paper describes the evolution of the system, from initial requirements definition and prototyping through design, implementation, testing, operational deployment, checkout and maintenance activities. The current status of the system and future plans for enhancement are described. Major challenges encountered during implementation are detailed.

  3. Ground-based thermal imaging of stream surface temperatures: Technique and evaluation

    Science.gov (United States)

    Bonar, Scott A.; Petre, Sally J.

    2015-01-01

    We evaluated a ground-based handheld thermal imaging system for measuring water temperatures using data from eight southwestern USA streams and rivers. We found handheld thermal imagers could provide considerably more spatial information on water temperature (for our unit one image = 19,600 individual temperature measurements) than traditional methods could supply without a prohibitive amount of effort. Furthermore, they could provide measurements of stream surface temperature almost instantaneously compared with most traditional handheld thermometers (e.g., >20 s/reading). Spatial temperature analysis is important for measurement of subtle temperature differences across waterways, and identification of warm and cold groundwater inputs. Handheld thermal imaging is less expensive and equipment intensive than airborne thermal imaging methods and is useful under riparian canopies. Disadvantages of handheld thermal imagers include their current higher expense than thermometers, their susceptibility to interference when used incorrectly, and their slightly lower accuracy than traditional temperature measurement methods. Thermal imagers can only measure surface temperature, but this usually corresponds to subsurface temperatures in well-mixed streams and rivers. Using thermal imaging in select applications, such as where spatial investigations of water temperature are needed, or in conjunction with stationary temperature data loggers or handheld electronic or liquid-in-glass thermometers to characterize stream temperatures by both time and space, could provide valuable information on stream temperature dynamics. These tools will become increasingly important to fisheries biologists as costs continue to decline.

  4. A Toolbox for Imaging Stellar Surfaces

    Science.gov (United States)

    Young, John

    2018-04-01

    In this talk I will review the available algorithms for synthesis imaging at visible and infrared wavelengths, including both gray and polychromatic methods. I will explain state-of-the-art approaches to constraining the ill-posed image reconstruction problem, and selecting an appropriate regularisation function and strength of regularisation. The reconstruction biases that can follow from non-optimal choices will be discussed, including their potential impact on the physical interpretation of the results. This discussion will be illustrated with example stellar surface imaging results from real VLTI and COAST datasets.

  5. Surface displacement imaging by interferometry with a light emitting diode

    International Nuclear Information System (INIS)

    Dilhaire, Stefan; Grauby, Stephane; Jorez, Sebastien; Lopez, Luis David Patino; Rampnoux, Jean-Michel; Claeys, Wilfrid

    2002-01-01

    We present an imaging technique to measure static surface displacements of electronic components. A device is supplied by a transient current that creates a variation of temperature, thus a surface displacement. To measure the latter, a setup that is based on a Michelson interferometer is used. To avoid the phenomenon of speckle and the drawbacks inherent to it, we use a light emitting diode as the light source for the interferometer. The detector is a visible CCD camera that analyzes the optical signal containing the information of surface displacement of the device. Combining images, we extract the amplitude of the surface displacement. Out-of-plane surface-displacement images of a thermoelectric device are presented

  6. Accuracy of deformable image registration on magnetic resonance images in digital and physical phantoms.

    Science.gov (United States)

    Ger, Rachel B; Yang, Jinzhong; Ding, Yao; Jacobsen, Megan C; Fuller, Clifton D; Howell, Rebecca M; Li, Heng; Jason Stafford, R; Zhou, Shouhao; Court, Laurence E

    2017-10-01

    Accurate deformable image registration is necessary for longitudinal studies. The error associated with commercial systems has been evaluated using computed tomography (CT). Several in-house algorithms have been evaluated for use with magnetic resonance imaging (MRI), but there is still relatively little information about MRI deformable image registration. This work presents an evaluation of two deformable image registration systems, one commercial (Velocity) and one in-house (demons-based algorithm), with MRI using two different metrics to quantify the registration error. The registration error was analyzed with synthetic MR images. These images were generated from interpatient and intrapatient variation models trained on 28 patients. Four synthetic post-treatment images were generated for each of four synthetic pretreatment images, resulting in 16 image registrations for both the T1- and T2-weighted images. The synthetic post-treatment images were registered to their corresponding synthetic pretreatment image. The registration error was calculated between the known deformation vector field and the generated deformation vector field from the image registration system. The registration error was also analyzed using a porcine phantom with ten implanted 0.35-mm diameter gold markers. The markers were visible on CT but not MRI. CT, T1-weighted MR, and T2-weighted MR images were taken in four different positions. The markers were contoured on the CT images and rigidly registered to their corresponding MR images. The MR images were deformably registered and the distance between the projected marker location and true marker location was measured as the registration error. The synthetic images were evaluated only on Velocity. Root mean square errors (RMSEs) of 0.76 mm in the left-right (LR) direction, 0.76 mm in the anteroposterior (AP) direction, and 0.69 mm in the superior-inferior (SI) direction were observed for the T1-weighted MR images. RMSEs of 1.1 mm in the LR

  7. Robotic 3D SQUID imaging system for practical nondestructive evaluation applications

    International Nuclear Information System (INIS)

    Isawa, K.; Nakayama, S.; Ikeda, M.; Takagi, S.; Tosaka, S.; Kasai, N.

    2005-01-01

    A robotic three-dimensional (3D) scanning superconducting quantum interference device (SQUID) imaging system was developed for practical nondestructive evaluation (NDE) applications. The major feature of this SQUID-NDE system is that the SQUID sensor itself scans in 3D by traveling over the surface of an object during testing without the need for magnetic shielding. This imaging system consists of (i) DC-SQUID gradiometer for effective movement of the sensor, (ii) SQUID sensor manipulator utilizing an articulated-type robot used in industry, (iii) laser charge-coupled-device (CCD) displacement sensor to measure the 3D coordinates of points on the surface of the object, and (iv) computer-aided numerical interpolation scheme for 3D surface reconstruction of the object. The applicability of this system for NDE was demonstrated by successfully detecting artificial damage of cylindrical-shaped steel tubes

  8. Multicenter evaluation of a new closed system drug-transfer device in reducing surface contamination by antineoplastic hazardous drugs.

    Science.gov (United States)

    Bartel, Sylvia B; Tyler, Timothy G; Power, Luci A

    2018-02-15

    Results of a study to evaluate the effectiveness of a recently introduced closed system drug-transfer device (CSTD) in reducing surface contamination during compounding and simulated administration of antineoplastic hazardous drugs (AHDs) are reported. Wipe samples were collected from 6 predetermined surfaces in compounding and infusion areas of 13 U.S. cancer centers to establish preexisting levels of surface contamination by 2 marker AHDs (cyclophosphamide and fluorouracil). Stainless steel templates were placed over the 6 previously sampled surfaces, and the marker drugs were compounded and infused per a specific protocol using all components of the CSTD. Wipe samples were collected from the templates after completion of tasks and analyzed for both marker AHDs. Aggregated results of wipe sampling to detect preexisting contamination at the 13 study sites showed that overall, 66.7% of samples (104 of 156) had detectable levels of at least 1 marker AHD; subsequent testing after CSTD use per protocol found a sample contamination rate of 5.8% (9 of 156 samples). In the administration areas alone, the rate of preexisting contamination was 78% (61 of 78 samples); with use of the CSTD protocol, the contamination rate was 2.6%. Twenty-six participants rated the CSTD for ease of use, with 100% indicating that they were satisfied or extremely satisfied. A study involving a rigorous protocol and 13 cancer centers across the United States demonstrated that the CSTD reduced surface contamination by cyclophosphamide and fluorouracil during compounding and simulated administration. Participants reported that the CSTD was easy to use. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  9. Tumor markers in pancreatic cancer: a European Group on Tumor Markers (EGTM) status report.

    LENUS (Irish Health Repository)

    Duffy, M J

    2012-02-01

    Pancreatic ductal adenocarcinoma is one of the most difficult malignancies to diagnose and treat. The aim of this article is to review how tumor markers can aid the diagnosis and management of patients with this malignancy. The most widely used and best validated marker for pancreatic cancer is CA 19-9. Inadequate sensitivity and specificity limit the use of CA 19-9 in the early diagnosis of pancreatic cancer. In non-jaundiced patients, however, CA 19-9 may complement other diagnostic procedures. In patients with resectable pancreatic cancer, presurgical and postresection CA 19-9 levels correlate with overall survival. In advanced disease, elevated pretreatment levels of CA 19-9 are associated with adverse patient outcome and thus may be combined with other factors for risk stratification. Most, but not all, reports indicate that serial levels of CA 19-9 correlate with response to systemic therapy. Use of CA 19-9 kinetics in conjunction with imaging is therefore recommended in monitoring therapy. Although several potential serum and tissue markers for pancreatic cancer are currently undergoing evaluation, none are sufficiently validated for routine clinical use. CA 19-9 thus remains the serum pancreatic cancer marker against which new markers for this malignancy should be judged.

  10. High performance multi-spectral interrogation for surface plasmon resonance imaging sensors.

    Science.gov (United States)

    Sereda, A; Moreau, J; Canva, M; Maillart, E

    2014-04-15

    Surface plasmon resonance (SPR) sensing has proven to be a valuable tool in the field of surface interactions characterization, especially for biomedical applications where label-free techniques are of particular interest. In order to approach the theoretical resolution limit, most SPR-based systems have turned to either angular or spectral interrogation modes, which both offer very accurate real-time measurements, but at the expense of the 2-dimensional imaging capability, therefore decreasing the data throughput. In this article, we show numerically and experimentally how to combine the multi-spectral interrogation technique with 2D-imaging, while finding an optimum in terms of resolution, accuracy, acquisition speed and reduction in data dispersion with respect to the classical reflectivity interrogation mode. This multi-spectral interrogation methodology is based on a robust five parameter fitting of the spectral reflectivity curve which enables monitoring of the reflectivity spectral shift with a resolution of the order of ten picometers, and using only five wavelength measurements per point. In fine, such multi-spectral based plasmonic imaging system allows biomolecular interaction monitoring in a linear regime independently of variations of buffer optical index, which is illustrated on a DNA-DNA model case. © 2013 Elsevier B.V. All rights reserved.

  11. Investigating the Lymphatic System by Dual-Color Elemental Mass Spectrometry Imaging

    Directory of Open Access Journals (Sweden)

    Ann-Christin Niehoff

    2017-01-01

    Full Text Available Secondary lymphedema accompanied with strong restrictions in quality of life is still major side effects in cancer therapy. Therefore, dedicated diagnostic tools and further investigation of the lymphatic system are crucial to improve lymphedema therapy. In this pilot study, a method for quantitative analysis of the lymphatic system in a rat model by laser ablation (LA with inductively coupled plasma mass spectrometry imaging (ICP-MSI is presented. As a possible lymph marker, thulium(III(1R,4R,7R,10R-α,α′,α′′,α′′′-tetramethyl-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetate (Tm-DOTMA is introduced and compared to the clinically used magnetic resonance imaging contrast agent gadolinium(III2,2′,2′′-(10-((2R,3S-1,3,4-trihydroxybutan-2-yl-1,4,7,10-tetraazacyclododecane-1,4,7-triyltriacetate (Gd-DO3A-butrol. Gadobutrol functioned as standard contrast media in MRI lymphangiography to detect lymphatic flow qualitatively. Thus, Tm-DOTMA was investigated as lymphatic marker to detect lymphatic flow quantitatively. Both contrast agents were successfully used to visualize the lymphatic flow in successive lymph nodes in LA-ICP-MS due to lower limits of detection compared to MRI. Furthermore, the distribution of contrast agents by multicolored imaging showed accumulation in specific areas (sectors of the lymph nodes after application of contrast agents in different areas.

  12. Development of a robust MRI fiducial system for automated fusion of MR-US abdominal images.

    Science.gov (United States)

    Favazza, Christopher P; Gorny, Krzysztof R; Callstrom, Matthew R; Kurup, Anil N; Washburn, Michael; Trester, Pamela S; Fowler, Charles L; Hangiandreou, Nicholas J

    2018-05-21

    We present the development of a two-component magnetic resonance (MR) fiducial system, that is, a fiducial marker device combined with an auto-segmentation algorithm, designed to be paired with existing ultrasound probe tracking and image fusion technology to automatically fuse MR and ultrasound (US) images. The fiducial device consisted of four ~6.4 mL cylindrical wells filled with 1 g/L copper sulfate solution. The algorithm was designed to automatically segment the device in clinical abdominal MR images. The algorithm's detection rate and repeatability were investigated through a phantom study and in human volunteers. The detection rate was 100% in all phantom and human images. The center-of-mass of the fiducial device was robustly identified with maximum variations of 2.9 mm in position and 0.9° in angular orientation. In volunteer images, average differences between algorithm-measured inter-marker spacings and actual separation distances were 0.53 ± 0.36 mm. "Proof-of-concept" automatic MR-US fusions were conducted with sets of images from both a phantom and volunteer using a commercial prototype system, which was built based on the above findings. Image fusion accuracy was measured to be within 5 mm for breath-hold scanning. These results demonstrate the capability of this approach to automatically fuse US and MR images acquired across a wide range of clinical abdominal pulse sequences. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  13. Effective Waterline Detection of Unmanned Surface Vehicles Based on Optical Images

    Directory of Open Access Journals (Sweden)

    Yangjie Wei

    2016-09-01

    Full Text Available Real-time and accurate detection of the sailing or water area will help realize unmanned surface vehicle (USV systems. Although there are some methods for using optical images in USV-oriented environmental modeling, both the robustness and precision of these published waterline detection methods are comparatively low for a real USV system moving in a complicated environment. This paper proposes an efficient waterline detection method based on structure extraction and texture analysis with respect to optical images and presents a practical application to a USV system for validation. First, the basic principles of local binary patterns (LBPs and gray level co-occurrence matrix (GLCM were analyzed, and their advantages were integrated to calculate the texture information of river images. Then, structure extraction was introduced to preprocess the original river images so that the textures resulting from USV motion, wind, and illumination are removed. In the practical application, the waterlines of many images captured by the USV system moving along an inland river were detected with the proposed method, and the results were compared with those of edge detection and super pixel segmentation. The experimental results showed that the proposed algorithm is effective and robust. The average error of the proposed method was 1.84 pixels, and the mean square deviation was 4.57 pixels.

  14. Distance of the image plane from metal surfaces

    International Nuclear Information System (INIS)

    Smith, N.V.; Chen, C.T.; Weinert, M.

    1989-01-01

    The data base of surface-state energies on the metals Cu, Ag, Au, Ni, Pd, and Pt is assembled and, with the aid of a simple model, is used to estimate the distance of the image plane and its trends from surface to surface and metal to metal. The model combines a nearly-free-electron representation of the crystal with a Jones-Jennings-Jepsen ansatz for the saturated image barrier. The projected bulk-band gaps are taken from published determinations. Constraints are placed on the surface barrier parameters by appeal to the results of self-consistent first-principles slab calculations. The general experimental trend observed is for the image-plane distance z 0 to decrease in the sequence (111) to (001) to (110), in the same sense but not as rapidly as z J , the distance of the effective jellium edge. This trend is rationalized using a simple model of the tail of the surface charge density. Typical values for z 0 -z J fall in the range -0.2 to +0.5 a.u., with the larger values occurring for the 3d metals Cu and Ni

  15. MO-FG-CAMPUS-TeP1-03: Pre-Treatment Surface Imaging Based Collision Detection

    Energy Technology Data Exchange (ETDEWEB)

    Wiant, D; Maurer, J; Liu, H; Hayes, T; Shang, Q; Sintay, B [Cone Health Cancer Center, Greensboro, NC (United States)

    2016-06-15

    Purpose: Modern radiotherapy increasingly employs large immobilization devices, gantry attachments, and couch rotations for treatments. All of which raise the risk of collisions between the patient and the gantry / couch. Collision detection is often achieved by manually checking each couch position in the treatment room and sometimes results in extraneous imaging if collisions are detected after image based setup has begun. In the interest of improving efficiency and avoiding extra imaging, we explore the use of a surface imaging based collision detection model. Methods: Surfaces acquired from AlignRT (VisionRT, London, UK) were transferred in wavefront format to a custom Matlab (Mathworks, Natick, MA) software package (CCHECK). Computed tomography (CT) scans acquired at the same time were sent to CCHECK in DICOM format. In CCHECK, binary maps of the surfaces were created and overlaid on the CT images based on the fixed relationship of the AlignRT and CT coordinate systems. Isocenters were added through a graphical user interface (GUI). CCHECK then compares the inputted surfaces to a model of the linear accelerator (linac) to check for collisions at defined gantry and couch positions. Note, CCHECK may be used with or without a CT. Results: The nominal surface image field of view is 650 mm × 900 mm, with variance based on patient position and size. The accuracy of collision detections is primarily based on the linac model and the surface mapping process. The current linac model and mapping process yield detection accuracies on the order of 5 mm, assuming no change in patient posture between surface acquisition and treatment. Conclusions: CCHECK provides a non-ionizing method to check for collisions without the patient in the treatment room. Collision detection accuracy may be improved with more robust linac modeling. Additional gantry attachments (e.g. conical collimators) can be easily added to the model.

  16. Comparison of surface coil and knee coil for evaluation of the patellar cartilage by MR imaging

    International Nuclear Information System (INIS)

    Steen, M. van den; Maeseneer, M. de; Hoste, M.; Vanderdood, K.; Ridder, F. de; Osteaux, M.

    2003-01-01

    Purpose: The aim of this work was to compare the knee coil and the surface coil for the visualisation of the patellar cartilage. Materials and methods: In 28 patients (17 women, 11 men) with an average age of 40 years (range 14-76) with knee pain MR was performed. Transverse images were obtained using a fast spin echo proton density weighted sequence on a Philips Gyroscan Intera 1.5 T clinical system. Transverse images were obtained at the level of the patellar cartilage using both the surface and the knee coil. All images were evaluated by consensus of two radiologists. They evaluated a number of quality criteria on a 4-point scale. Criteria for artefacts were also graded on a 4-point scale. Results: For the visualisation of fluid there was no significant difference between the knee coil and the surface coil (P=0.021). For all other criteria regarding image quality and presence of imaging artefacts there was a significant difference between both coils (P<0.001) with the surface coil obtaining the better result. Conclusion: The use of the surface coil in the visualisation of the patellar cartilage can be recommended at knee MR

  17. A hybrid optical system for broadband imaging in guidance and control

    Science.gov (United States)

    Wu, Xiaofang; Jiang, Yuesong; Shen, Chunyan; Zhao, Yiming

    2006-11-01

    A binary optics method has been adopted to improve upon a conventional optical system in guidance and control, and a hybrid broadband imaging system that includes a binary surface is analyzed and evaluated by optical design software ZEMAX. The practical design shows that the introduction of binary optics can simplify the structure of the imaging system and reduce the size and weight of the broadband guidance and control system. Moreover, it can help to acquire images of radiation of different wavelengths from targets; hence it will result in improved overall performance of missiles in wars.

  18. SU-E-J-53: A Phantom Design to Assist Patient Position Verification System in Daily Image-Guided RT and Comprehensive QA Measurements

    International Nuclear Information System (INIS)

    Syh, J; Wu, H

    2015-01-01

    Purpose This study is to implement a homemade novel device with surface locking couch index to check daily radiograph (DR) function of adaPTInsight™, stereoscopic image guided system (SIGS), for proton therapy. The comprehensive daily QA checks of proton pencil beam output, field size, flatness and symmetry of spots and energy layers will be followed by using MatriXX dosimetry device. Methods The iBa MatriXX device was used to perform daily dosimetry which is also used to perform SIGS checks. A set of markers were attached to surface of MatriXX device in alignment of DRR of reconstructed CT images and daily DR. The novel device allows MatriXX to be fit into the cradle which was locked by couch index bars on couch surface. This will keep the MatriXX at same XY plane daily with exact coordinates. Couch height Z will be adjusted according to imaging to check isocenter-laser coincidence accuracy. Results adaPTInsight™ provides robotic couch to move in 6-degree coordinate system to align the dosimetry device to be within 1.0 mm / 1.0°. The daily constancy was tightened to be ± 0.5 mm / 0.3° compared to 1.0 mm / 1.0° before. For gantry at 0° and couch all 0° angles (@ Rt ARM 0 setting), offsets measured of the couch systems were ≤ 0.5° in roll, yaw and pitch dimensions. Conclusion Simplicity of novel device made daily image guided QA consistent with accuracy. The offset of the MatriXX isocenter-laser coincident was reproducible. Such easy task not only speeds up the setup, but it increases confidence level in detailed daily comprehensive measurements. The total SIGS alignment time has been shortened with less setup error. This device will enhance our experiences for the future QA when cone beam CT imaging modality becomes available at proton therapy center

  19. The fibroblast surface markers FAP, anti-fibroblast, and FSP are expressed by cells of epithelial origin and may be altered during epithelial-to-mesenchymal transition.

    Science.gov (United States)

    Kahounová, Zuzana; Kurfürstová, Daniela; Bouchal, Jan; Kharaishvili, Gvantsa; Navrátil, Jiří; Remšík, Ján; Šimečková, Šárka; Študent, Vladimír; Kozubík, Alois; Souček, Karel

    2017-04-06

    The identification of fibroblasts and cancer-associated fibroblasts from human cancer tissue using surface markers is difficult, especially because the markers used currently are usually not expressed solely by fibroblasts, and the identification of fibroblast-specific surface molecules is still under investigation. It was aimed to compare three commercially available antibodies in the detection of different surface epitopes of fibroblasts (anti-fibroblast, fibroblast activation protein α, and fibroblast surface protein). The specificity of their expression, employing fibroblast cell lines and tumor-derived fibroblasts from breast and prostate tissues was investigated. Both the established fibroblast cell line HFF-1 and ex vivo primary fibroblasts isolated from breast and prostate cancer tissues expressed the tested surface markers to different degrees. Surprisingly, those markers were expressed also by permanent cell lines of epithelial origin, both benign and cancer-derived (breast-cell lines MCF 10A, HMLE and prostate-cell lines BPH-1, DU 145, and PC-3). The expression of fibroblast activation protein α increased on the surface of previously described models of epithelial cells undergoing epithelial-to-mesenchymal transition in response to treatment with TGF-β1. To prove the co-expression of the fibroblast markers on cells of epithelial origin, we used freshly dissociated human prostate and breast cancer tissues. The results confirmed the co-expression of anti-fibroblast and fibroblast surface protein on CD31/CD45-negative/EpCAM-positive epithelial cells. In summary, our data support the findings that the tested fibroblast markers are not fibroblast specific and may be expressed also by cells of epithelial origin (e.g., cells undergoing EMT). Therefore, the expression of these markers should be interpreted with caution, and the combination of several epitopes for both positive (anti-fibroblast or fibroblast activation protein α) and negative (Ep

  20. Image to physical space registration of supine breast MRI for image guided breast surgery

    Science.gov (United States)

    Conley, Rebekah H.; Meszoely, Ingrid M.; Pheiffer, Thomas S.; Weis, Jared A.; Yankeelov, Thomas E.; Miga, Michael I.

    2014-03-01

    Breast conservation therapy (BCT) is a desirable option for many women diagnosed with early stage breast cancer and involves a lumpectomy followed by radiotherapy. However, approximately 50% of eligible women will elect for mastectomy over BCT despite equal survival benefit (provided margins of excised tissue are cancer free) due to uncertainty in outcome with regards to complete excision of cancerous cells, risk of local recurrence, and cosmesis. Determining surgical margins intraoperatively is difficult and achieving negative margins is not as robust as it needs to be, resulting in high re-operation rates and often mastectomy. Magnetic resonance images (MRI) can provide detailed information about tumor margin extents, however diagnostic images are acquired in a fundamentally different patient presentation than that used in surgery. Therefore, the high quality diagnostic MRIs taken in the prone position with pendant breast are not optimal for use in surgical planning/guidance due to the drastic shape change between preoperative images and the common supine surgical position. This work proposes to investigate the value of supine MRI in an effort to localize tumors intraoperatively using image-guidance. Mock intraoperative setups (realistic patient positioning in non-sterile environment) and preoperative imaging data were collected from a patient scheduled for a lumpectomy. The mock intraoperative data included a tracked laser range scan of the patient's breast surface, tracked center points of MR visible fiducials on the patient's breast, and tracked B-mode ultrasound and strain images. The preoperative data included a supine MRI with visible fiducial markers. Fiducial markers localized in the MRI were rigidly registered to their mock intraoperative counterparts using an optically tracked stylus. The root mean square (RMS) fiducial registration error using the tracked markers was 3.4mm. Following registration, the average closest point distance between the MR

  1. Image Simulation and Assessment of the Colour and Spatial Capabilities of the Colour and Stereo Surface Imaging System (CaSSIS) on the ExoMars Trace Gas Orbiter

    Science.gov (United States)

    Tornabene, Livio L.; Seelos, Frank P.; Pommerol, Antoine; Thomas, Nicholas; Caudill, C. M.; Becerra, Patricio; Bridges, John C.; Byrne, Shane; Cardinale, Marco; Chojnacki, Matthew; Conway, Susan J.; Cremonese, Gabriele; Dundas, Colin M.; El-Maarry, M. R.; Fernando, Jennifer; Hansen, Candice J.; Hansen, Kayle; Harrison, Tanya N.; Henson, Rachel; Marinangeli, Lucia; McEwen, Alfred S.; Pajola, Maurizio; Sutton, Sarah S.; Wray, James J.

    2018-02-01

    This study aims to assess the spatial and visible/near-infrared (VNIR) colour/spectral capabilities of the 4-band Colour and Stereo Surface Imaging System (CaSSIS) aboard the ExoMars 2016 Trace Grace Orbiter (TGO). The instrument response functions for the CaSSIS imager was used to resample spectral libraries, modelled spectra and to construct spectrally ( i.e., in I/F space) and spatially consistent simulated CaSSIS image cubes of various key sites of interest and for ongoing scientific investigations on Mars. Coordinated datasets from Mars Reconnaissance Orbiter (MRO) are ideal, and specifically used for simulating CaSSIS. The Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) provides colour information, while the Context Imager (CTX), and in a few cases the High-Resolution Imaging Science Experiment (HiRISE), provides the complementary spatial information at the resampled CaSSIS unbinned/unsummed pixel resolution (4.6 m/pixel from a 400-km altitude). The methodology used herein employs a Gram-Schmidt spectral sharpening algorithm to combine the ˜18-36 m/pixel CRISM-derived CaSSIS colours with I/F images primarily derived from oversampled CTX images. One hundred and eighty-one simulated CaSSIS 4-colour image cubes (at 18-36 m/pixel) were generated (including one of Phobos) based on CRISM data. From these, thirty-three "fully"-simulated image cubes of thirty unique locations on Mars ( i.e., with 4 colour bands at 4.6 m/pixel) were made. All simulated image cubes were used to test both the colour capabilities of CaSSIS by producing standard colour RGB images, colour band ratio composites (CBRCs) and spectral parameters. Simulated CaSSIS CBRCs demonstrated that CaSSIS will be able to readily isolate signatures related to ferrous (Fe2+) iron- and ferric (Fe3+) iron-bearing deposits on the surface of Mars, ices and atmospheric phenomena. Despite the lower spatial resolution of CaSSIS when compared to HiRISE, the results of this work demonstrate that Ca

  2. MR imaging of brain surface structures

    International Nuclear Information System (INIS)

    Katada, Kazuhiro; Anno, Hirofumi; Takesita, Gen; Koga, Sukehiko; Kanno, Tetuo; Sakakibara, Tatuo; Yamada, Kazuhiro; Suzuki, Hirokazu; Saito, Sigeki.

    1989-01-01

    An imaging technique that permits direct and non-invasive visualization of brain surface structures was proposed. This technique (Surface anatomy scanning, SAS) consists of long TE-long TR spin echo sequence, thick slice and surface coil. Initial clinical trials in 31 patients with various cerebral pathology showed excellent visualization of sulci, gyri and major cortical veins on the lateral surface of the brain together with cortical and subcortical lesions. Our preliminary results indicate that the SAS is an effective method for the diagnosis and localization of cortical and subcortical pathology, and the possible application of SAS to the surgical and the radiation therapy planning is sugessted. (author)

  3. Image acquisition and planimetry systems to develop wounding techniques in 3D wound model

    Directory of Open Access Journals (Sweden)

    Kiefer Ann-Kathrin

    2017-09-01

    Full Text Available Wound healing represents a complex biological repair process. Established 2D monolayers and wounding techniques investigate cell migration, but do not represent coordinated multi-cellular systems. We aim to use wound surface area measurements obtained from image acquisition and planimetry systems to establish our wounding technique and in vitro organotypic tissue. These systems will be used in our future wound healing treatment studies to assess the rate of wound closure in response to wound healing treatment with light therapy (photobiomodulation. The image acquisition and planimetry systems were developed, calibrated, and verified to measure wound surface area in vitro. The system consists of a recording system (Sony DSC HX60, 20.4 M Pixel, 1/2.3″ CMOS sensor and calibrated with 1mm scale paper. Macro photography with an optical zoom magnification of 2:1 achieves sufficient resolution to evaluate the 3mm wound size and healing growth. The camera system was leveled with an aluminum construction to ensure constant distance and orientation of the images. The JPG-format images were processed with a planimetry system in MATLAB. Edge detection enables definition of the wounded area. Wound area can be calculated with surface integrals. To separate the wounded area from the background, the image was filtered in several steps. Agar models, injured through several test persons with different levels of experience, were used as pilot data to test the planimetry software. These image acquisition and planimetry systems support the development of our wound healing research. The reproducibility of our wounding technique can be assessed by the variability in initial wound surface area. Also, wound healing treatment effects can be assessed by the change in rate of wound closure. These techniques represent the foundations of our wound model, wounding technique, and analysis systems in our ongoing studies in wound healing and therapy.

  4. Digital image processing: Cylindrical surface plane development of CAREM fuel pellets

    International Nuclear Information System (INIS)

    Caccavelli, J; Cativa Tolosa, S; Gommes, C

    2012-01-01

    As part of the development of fuel pellets (FPs) for nuclear reactor CAREM-25, is necessary to systematize the analysis of the mechanical integrity of the FPs that is now done manually by a human operator. Following specifications and standards of reference for this purpose, the FPs should be inspected visually for detecting material discontinuities in the FPs surfaces to minimize any deterioration, loss of material and excessive breakage during operation and load of fuel bars. The material discontinuities are classified into two defects: surface cracks and chips. For each of these surface defects exist acceptance criteria that determine if the fuel pellet (FP) as a whole is accepted or rejected. One criteria for surface cracks is that they do not exceed one third (1/3) of the circumferential surface of the FP. The FP has cylindrical shape, so some of these acceptance criteria make difficult to analyze the FP in a single photographic image. Depending on the axial rotation of the FP, the crack could not be entirely visualized on the picture frame. Even a single crack that appears in different parts of the FP rotated images may appear to be different cracks in the FP when it is actually one. For this reason it is necessary, for the automatic detection and measurement of surface defects, obtain the circumferential surface of the FP into a single image in order to decide the acceptance or reject of the FP. As the FP shape is cylindrical, it is possible to obtain the flat development of the cylindrical surface (surface unrolling) of the FPs into a single image combining the image set of the axial rotation of the FP. In this work, we expose the procedure to implement the flat development of the cylindrical surface (surface unrolling). Starting from a photographic image of the FP surface, which represents the projection of a cylinder in the plane, we obtain three-dimensional information of each point on the cylindrical surface of the FP (3D-mapping). Then, we can

  5. A selectable and excisable marker system for the rapid creation of recombinant poxviruses.

    Directory of Open Access Journals (Sweden)

    Julia L Rintoul

    Full Text Available Genetic manipulation of poxvirus genomes through attenuation, or insertion of therapeutic genes has led to a number of vector candidates for the treatment of a variety of human diseases. The development of recombinant poxviruses often involves the genomic insertion of a selectable marker for purification and selection purposes. The use of marker genes however inevitably results in a vector that contains unwanted genetic information of no therapeutic value.Here we describe an improved strategy that allows for the creation of marker-free recombinant poxviruses of any species. The Selectable and Excisable Marker (SEM system incorporates a unique fusion marker gene for the efficient selection of poxvirus recombinants and the Cre/loxP system to facilitate the subsequent removal of the marker. We have defined and characterized this new methodological tool by insertion of a foreign gene into vaccinia virus, with the subsequent removal of the selectable marker. We then analyzed the importance of loxP orientation during Cre recombination, and show that the SEM system can be used to introduce site-specific deletions or inversions into the viral genome. Finally, we demonstrate that the SEM strategy is amenable to other poxviruses, as demonstrated here with the creation of an ectromelia virus recombinant lacking the EVM002 gene.The system described here thus provides a faster, simpler and more efficient means to create clinic-ready recombinant poxviruses for therapeutic gene therapy applications.

  6. Medical imaging systems

    Science.gov (United States)

    Frangioni, John V [Wayland, MA

    2012-07-24

    A medical imaging system provides simultaneous rendering of visible light and fluorescent images. The system may employ dyes in a small-molecule form that remains in a subject's blood stream for several minutes, allowing real-time imaging of the subject's circulatory system superimposed upon a conventional, visible light image of the subject. The system may also employ dyes or other fluorescent substances associated with antibodies, antibody fragments, or ligands that accumulate within a region of diagnostic significance. In one embodiment, the system provides an excitation light source to excite the fluorescent substance and a visible light source for general illumination within the same optical guide that is used to capture images. In another embodiment, the system is configured for use in open surgical procedures by providing an operating area that is closed to ambient light. More broadly, the systems described herein may be used in imaging applications where a visible light image may be usefully supplemented by an image formed from fluorescent emissions from a fluorescent substance that marks areas of functional interest.

  7. An Efficiency Analysis of Augmented Reality Marker Recognition Algorithm

    Directory of Open Access Journals (Sweden)

    Kurpytė Dovilė

    2014-05-01

    Full Text Available The article reports on the investigation of augmented reality system which is designed for identification and augmentation of 100 different square markers. Marker recognition efficiency was investigated by rotating markers along x and y axis directions in range from −90° to 90°. Virtual simulations of four environments were developed: a an intense source of light, b an intense source of light falling from the left side, c the non-intensive light source falling from the left side, d equally falling shadows. The graphics were created using the OpenGL graphics computer hardware interface; image processing was programmed in C++ language using OpenCV, while augmented reality was developed in Java programming language using NyARToolKit. The obtained results demonstrate that augmented reality marker recognition algorithm is accurate and reliable in the case of changing lighting conditions and rotational angles - only 4 % markers were unidentified. Assessment of marker recognition efficiency let to propose marker classification strategy in order to use it for grouping various markers into distinct markers’ groups possessing similar recognition properties.

  8. Performing chemical reactions in virtual capillary of surface tension ...

    Indian Academy of Sciences (India)

    The flow paths were fabricated by making parallel lines using permanent marker pen ink or other polymer on glass surfaces. Two mirror image patterned glass plates were then sandwiched one on top of the other, separated by a thin gap - created using a spacer. The aqueous liquid moves between the surfaces by capillary ...

  9. Lipiodol as a Fiducial Marker for Image-Guided Radiation Therapy for Bladder Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Freilich, Jessica M.; Spiess, Philippe E.; Biagioli, Matthew C.; Fernandez, Daniel C.; Shi, Ellen J.; Hunt, Dylan C.; Gupta, Shilpa; Wilder, Richard B., E-mail: richard.wilder@moffitt.org [Moffitt Cancer Center, Tampa, FL (United States)

    2014-03-15

    Purpose: To evaluate Lipiodol as a liquid, radio-opaque fiducial marker for image-guided radiation therapy (IGRT) for bladder cancer; Materials and Methods: Between 2011 and 2012, 5 clinical T2a-T3b N0 M0 stage II-III bladder cancer patients were treated with maximal transurethral resection of a bladder tumor (TURBT) and image-guided radiation therapy (IGRT) to 64.8 Gy in 36 fractions ± concurrent weekly cisplatin-based or gemcitabine chemotherapy. Ten to 15mL Lipiodol, using 0.5mL per injection, was injected into bladder submucosa circumferentially around the entire periphery of the tumor bed immediately following maximal TURBT. The authors looked at inter-observer variability regarding the size and location of the tumor bed (CTVboost) on computed tomography scans with versus without Lipiodol. Results: Median follow-up was 18 months. Lipiodol was visible on every orthogonal two-dimensional kV portal image throughout the entire, 7-week course of IGRT. There was a trend towards improved inter-observer agreement on the CTVboost with Lipiodol (p = 0.06). In 2 of 5 patients, the tumor bed based upon Lipiodol extended outside a planning target volume that would have been treated with a radiation boost based upon a cystoscopy report and an enhanced computed tomography (CT) scan for staging. There was no toxicity attributable to Lipiodol: Conclusions: Lipiodol constitutes a safe and effective fiducial marker that an urologist can use to demarcate a tumor bed immediately following maximal TURBT. Lipiodol decreases inter-observer variability in the definition of the extent and location of a tumor bed on a treatment planning CT scan for a radiation boost. (author)

  10. Lipiodol as a Fiducial Marker for Image-Guided Radiation Therapy for Bladder Cancer

    Directory of Open Access Journals (Sweden)

    Jessica M. Freilich

    2014-04-01

    Full Text Available Purpose To evaluate Lipiodol as a liquid, radio-opaque fiducial marker for image-guided radiation therapy (IGRT for bladder cancer.Materials and Methods Between 2011 and 2012, 5 clinical T2a-T3b N0 M0 stage II-III bladder cancer patients were treated with maximal transurethral resection of a bladder tumor (TURBT and image-guided radiation therapy (IGRT to 64.8 Gy in 36 fractions ± concurrent weekly cisplatin-based or gemcitabine chemotherapy. Ten to 15mL Lipiodol, using 0.5mL per injection, was injected into bladder submucosa circumferentially around the entire periphery of the tumor bed immediately following maximal TURBT. The authors looked at inter-observer variability regarding the size and location of the tumor bed (CTVboost on computed tomography scans with versus without Lipiodol.Results Median follow-up was 18 months. Lipiodol was visible on every orthogonal two-dimensional kV portal image throughout the entire, 7-week course of IGRT. There was a trend towards improved inter-observer agreement on the CTVboost with Lipiodol (p = 0.06. In 2 of 5 patients, the tumor bed based upon Lipiodol extended outside a planning target volume that would have been treated with a radiation boost based upon a cystoscopy report and an enhanced computed tomography (CT scan for staging. There was no toxicity attributable to Lipiodol.Conclusions Lipiodol constitutes a safe and effective fiducial marker that an urologist can use to demarcate a tumor bed immediately following maximal TURBT. Lipiodol decreases inter-observer variability in the definition of the extent and location of a tumor bed on a treatment planning CT scan for a radiation boost.

  11. Ovarian Surface Epithelium in Patients with Severe Ovarian Infertility: A Potential Source of Cells Expressing Markers of Pluripotent/Multipotent Stem Cells

    Directory of Open Access Journals (Sweden)

    Irma Virant-Klun

    2011-01-01

    Full Text Available The aim of this study was to confirm the presence of stem cells in the ovarian surface epithelium of patients with premature ovarian failure and no mature follicles and oocytes. In these patients, small round cells of unknown origin expressing SOX-2 marker of pluripotency were observed among the epithelial cells just after the ovarian surface epithelium scraping. These cells were an integral part of the ovarian surface epithelium. When the scraped cells were cultured in a medium with added follicular fluid to provide some ovarian niche, primitive oocyte-like cells and typical round-shaped cell clusters positively stained on alkaline phosphatase, and markers of pluripotency, such as SOX-2 and SSEA-4, were developed. These markers were expressed early and also later in the culture. Single oocyte-like cells expressed genes OCT4A, SOX-2, NANOG, NANOS, STELLA, CD9, LIN28, KLF4, GDF3, and MYC, characteristic for pluripotent stem cells. The results of this study confirmed the presence of putative stem cells in the ovarian surface epithelium of these patients and provided some basis to create a stem cell line in the future.

  12. Development of automatic navigation measuring system using template-matching software in image guided neurosurgery

    International Nuclear Information System (INIS)

    Watanabe, Yohei; Hayashi, Yuichiro; Fujii, Masazumi; Wakabayashi, Toshihiko; Kimura, Miyuki; Tsuzaka, Masatoshi; Sugiura, Akihiro

    2010-01-01

    An image-guided neurosurgery and neuronavigation system based on magnetic resonance imaging has been used as an indispensable tool for resection of brain tumors. Therefore, accuracy of the neuronavigation system, provided by periodic quality assurance (QA), is essential for image-guided neurosurgery. Two types of accuracy index, fiducial registration error (FRE) and target registration error (TRE), have been used to evaluate navigation accuracy. FRE shows navigation accuracy on points that have been registered. On the other hand, TRE shows navigation accuracy on points such as tumor, skin, and fiducial markers. This study shows that TRE is more reliable than FRE. However, calculation of TRE is a time-consuming, subjective task. Software for QA was developed to compute TRE. This software calculates TRE automatically by an image processing technique, such as automatic template matching. TRE was calculated by the software and compared with the results obtained by manual calculation. Using the software made it possible to achieve a reliable QA system. (author)

  13. A small animal holding fixture system with positional reproducibility for longitudinal multimodal imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kokuryo, Daisuke; Kimura, Yuichi; Obata, Takayuki; Yamaya, Taiga; Kawamura, Kazunori; Zhang, Ming-Rong; Kanno, Iwao; Aoki, Ichio, E-mail: ukimura@ieee.or [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage, Chiba 263-8555 (Japan)

    2010-07-21

    This study presents a combined small animal holding fixture system, termed a 'bridge capsule', which provides for small animal re-fixation with positional reproducibility. This system comprises separate holding fixtures for the head and lower body and a connecting part to a gas anesthesia system. A mouse is fixed in place by the combination of a head fixture with a movable part made from polyacetal resin, a lower body fixture made from vinyl-silicone and a holder for the legs and tail. For re-fixation, a similar posture could be maintained by the same holding fixtures and a constant distance between the head and lower body fixtures is maintained. Artifacts caused by the bridge capsule system were not observed on magnetic resonance (MRI) and positron emission tomography (PET) images. The average position differences of the spinal column and the iliac body before and after re-fixation for the same modality were approximately 1.1 mm. The difference between the MRI and PET images was approximately 1.8 mm for the lower body fixture after image registration using fiducial markers. This system would be useful for longitudinal, repeated and multimodal imaging experiments requiring similar animal postures.

  14. Nanoscale imaging of surface piezoresponse on GaN epitaxial layers

    International Nuclear Information System (INIS)

    Stoica, T.; Calarco, R.; Meijers, R.; Lueth, H.

    2007-01-01

    Surfaces of GaN films were investigated by atomic force microscopy (AFM) with implemented piezoelectric force microscopy technique. A model of PFM based on the surface depletion region in GaN films is discussed. The local piezoelectric effect of the low frequency regime was found to be in phase with the applied voltage on large domains, corresponding to a Ga-face of the GaN layer. Low piezoresponse is obtained within the inter-domain regions. The use of frequencies near a resonance frequency enhances very much the resolution of piezo-imaging, but only for very low scanning speed the piezo-imaging can follow the local piezoelectric effect. An inversion of the PFM image contrast is obtained for frequencies higher than the resonance frequencies. The effect of a chemical surface treatment on the topography and the piezoresponse of the GaN films was also investigated. Textured surfaces with very small domains were observed after the chemical treatment. For this kind of surfaces, piezo-induced torsion rather than bending of the AFM cantilever dominates the contrast of the PFM images. A small memory effect was observed, and explained by surface charging and confinement of the piezoelectric effect within the carrier depletion region at the GaN surface

  15. Surface Casting Defects Inspection Using Vision System and Neural Network Techniques

    Directory of Open Access Journals (Sweden)

    Świłło S.J.

    2013-12-01

    Full Text Available The paper presents a vision based approach and neural network techniques in surface defects inspection and categorization. Depending on part design and processing techniques, castings may develop surface discontinuities such as cracks and pores that greatly influence the material’s properties Since the human visual inspection for the surface is slow and expensive, a computer vision system is an alternative solution for the online inspection. The authors present the developed vision system uses an advanced image processing algorithm based on modified Laplacian of Gaussian edge detection method and advanced lighting system. The defect inspection algorithm consists of several parameters that allow the user to specify the sensitivity level at which he can accept the defects in the casting. In addition to the developed image processing algorithm and vision system apparatus, an advanced learning process has been developed, based on neural network techniques. Finally, as an example three groups of defects were investigated demonstrates automatic selection and categorization of the measured defects, such as blowholes, shrinkage porosity and shrinkage cavity.

  16. A System for Drawing Synthetic Images of Forested Landscapes

    Science.gov (United States)

    Timothy P. McDonald

    1997-01-01

    A software package for drawing images of forested landscapes was developed. Programs included in the system convert topographic and stand polygon information output from a GIS into a form that can be read by a general-purpose ray-tracing renderer. Other programs generate definitions for surface features, mainly trees but ground surface textural properties as well. The...

  17. The Stellar Imager (SI) Project: Resolving Stellar Surfaces, Interiors, and Magnetic Activity

    Science.gov (United States)

    Carpenter, Kenneth G.; Schrijver, K.; Karovska, M.

    2007-01-01

    The Stellar Imager (SI) is a UV/Optical. Space-Based Interferometer designed to enable 0.1 milli-arcsec (mas) spectral imaging of stellar surfaces and, via asteroseismology, stellar interiors and of the Universe in general. The ultra-sharp images of SI will revolutionize our view of many dynamic astrophysical processes by transforming point sources into extended sources, and snapshots into evolving views. The science of SI focuses on the role of magnetism in the Universe, particularly on magnetic activity on the surfaces of stars like the Sun. Its prime goal is to enable long-term forecasting of solar activity and the space weather that it drives. SI will also revolutionize our understanding of the formation of planetary systems, of the habitability and climatology of distant planets, and of many magneto-hydrodynamically controlled processes in the Universe. In this paper we discuss the science goals, technology needs, and baseline design of the SI mission.

  18. Portable multispectral imaging system for oral cancer diagnosis

    Science.gov (United States)

    Hsieh, Yao-Fang; Ou-Yang, Mang; Lee, Cheng-Chung

    2013-09-01

    This study presents the portable multispectral imaging system that can acquire the image of specific spectrum in vivo for oral cancer diagnosis. According to the research literature, the autofluorescence of cells and tissue have been widely applied to diagnose oral cancer. The spectral distribution is difference for lesions of epithelial cells and normal cells after excited fluorescence. We have been developed the hyperspectral and multispectral techniques for oral cancer diagnosis in three generations. This research is the third generation. The excited and emission spectrum for the diagnosis are acquired from the research of first generation. The portable system for detection of oral cancer is modified for existing handheld microscope. The UV LED is used to illuminate the surface of oral cavity and excite the cells to produce fluorescent. The image passes through the central channel and filters out unwanted spectrum by the selection of filter, and focused by the focus lens on the image sensor. Therefore, we can achieve the specific wavelength image via fluorescence reaction. The specificity and sensitivity of the system are 85% and 90%, respectively.

  19. Comparison between low-cost marker-less and high-end marker-based motion capture systems for the computer-aided assessment of working ergonomics.

    Science.gov (United States)

    Patrizi, Alfredo; Pennestrì, Ettore; Valentini, Pier Paolo

    2016-01-01

    The paper deals with the comparison between a high-end marker-based acquisition system and a low-cost marker-less methodology for the assessment of the human posture during working tasks. The low-cost methodology is based on the use of a single Microsoft Kinect V1 device. The high-end acquisition system is the BTS SMART that requires the use of reflective markers to be placed on the subject's body. Three practical working activities involving object lifting and displacement have been investigated. The operational risk has been evaluated according to the lifting equation proposed by the American National Institute for Occupational Safety and Health. The results of the study show that the risk multipliers computed from the two acquisition methodologies are very close for all the analysed activities. In agreement to this outcome, the marker-less methodology based on the Microsoft Kinect V1 device seems very promising to promote the dissemination of computer-aided assessment of ergonomics while maintaining good accuracy and affordable costs. PRACTITIONER’S SUMMARY: The study is motivated by the increasing interest for on-site working ergonomics assessment. We compared a low-cost marker-less methodology with a high-end marker-based system. We tested them on three different working tasks, assessing the working risk of lifting loads. The two methodologies showed comparable precision in all the investigations.

  20. Reflective optical imaging system for extreme ultraviolet wavelengths

    Science.gov (United States)

    Viswanathan, V.K.; Newnam, B.E.

    1993-05-18

    A projection reflection optical system has two mirrors in a coaxial, four reflection configuration to reproduce the image of an object. The mirrors have spherical reflection surfaces to provide a very high resolution of object feature wavelengths less than 200 [mu]m, and preferably less than 100 [mu]m. An image resolution of features less than 0.05-0.1 [mu]m, is obtained over a large area field; i.e., 25.4 mm [times] 25.4 mm, with a distortion less than 0.1 of the resolution over the image field.

  1. TH-CD-207A-09: Stay On Target: Dynamic, Patient-Specific Templates of Fiducial Marker Clusters for IGRT

    International Nuclear Information System (INIS)

    Campbell, W; Miften, M; Jones, B

    2016-01-01

    Purpose: Pancreatic SBRT relies on extremely accurate delivery of ablative radiation doses to the target, and intra-fractional tracking of fiducial markers can facilitate improvements in dose delivery. However, this requires algorithms that are able to find fiducial markers with high speed and accuracy. The purpose of this study was to develop a novel marker tracking algorithm that is robust against many of the common errors seen with traditional template matching techniques. Methods: Using CBCT projection images, a method was developed to create detailed template images of fiducial marker clusters without prior knowledge of the number of markers, their positions, or their orientations. Briefly, the method (i) enhances markers in projection images, (ii) stabilizes the cluster’s position, (iii) reconstructs the cluster in 3D, and (iv) precomputes a set of static template images dependent on gantry angle. Furthermore, breathing data were used to produce 4D reconstructions of clusters, yielding dynamic template images dependent on gantry angle and breathing amplitude. To test these two approaches, static and dynamic templates were used to track the motion of marker clusters in more than 66,000 projection images from 75 CBCT scans of 15 pancreatic SBRT patients. Results: For both static and dynamic templates, the new technique was able to locate marker clusters present in projection images 100% of the time. The algorithm was also able to correctly locate markers in several instances where only some of the markers were visible due to insufficient field-of-view. In cases where clusters exhibited deformation and/or rotation during breathing, dynamic templates resulted in cross-correlation scores up to 70% higher than static templates. Conclusion: Patient-specific templates provided complete tracking of fiducial marker clusters in CBCT scans, and dynamic templates helped to provide higher cross-correlation scores for deforming/rotating clusters. This novel algorithm

  2. TH-CD-207A-09: Stay On Target: Dynamic, Patient-Specific Templates of Fiducial Marker Clusters for IGRT

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, W; Miften, M; Jones, B [Department of Radiation Oncology, University of Colorado School of Medicine, Aurora, CO (United States)

    2016-06-15

    Purpose: Pancreatic SBRT relies on extremely accurate delivery of ablative radiation doses to the target, and intra-fractional tracking of fiducial markers can facilitate improvements in dose delivery. However, this requires algorithms that are able to find fiducial markers with high speed and accuracy. The purpose of this study was to develop a novel marker tracking algorithm that is robust against many of the common errors seen with traditional template matching techniques. Methods: Using CBCT projection images, a method was developed to create detailed template images of fiducial marker clusters without prior knowledge of the number of markers, their positions, or their orientations. Briefly, the method (i) enhances markers in projection images, (ii) stabilizes the cluster’s position, (iii) reconstructs the cluster in 3D, and (iv) precomputes a set of static template images dependent on gantry angle. Furthermore, breathing data were used to produce 4D reconstructions of clusters, yielding dynamic template images dependent on gantry angle and breathing amplitude. To test these two approaches, static and dynamic templates were used to track the motion of marker clusters in more than 66,000 projection images from 75 CBCT scans of 15 pancreatic SBRT patients. Results: For both static and dynamic templates, the new technique was able to locate marker clusters present in projection images 100% of the time. The algorithm was also able to correctly locate markers in several instances where only some of the markers were visible due to insufficient field-of-view. In cases where clusters exhibited deformation and/or rotation during breathing, dynamic templates resulted in cross-correlation scores up to 70% higher than static templates. Conclusion: Patient-specific templates provided complete tracking of fiducial marker clusters in CBCT scans, and dynamic templates helped to provide higher cross-correlation scores for deforming/rotating clusters. This novel algorithm

  3. Three-dimensional surface reconstruction imaging for evaluation of congenital heart disease from ECG-triggered MR images

    International Nuclear Information System (INIS)

    Vannier, M.W.; Laschinger, J.; Knapp, R.H.; Gutierrez, F.R.; Gronnemeyer, S.A.

    1987-01-01

    Three-dimensional surface reconstruction images of the heart and great vessels were produced from contiguous sequences of electrocardiographically triggered MR images in 25 patients with congenital heart disease and in three healthy subjects. The imaging data were semiautomatically processed to separate the epicardial and endocardial surfaces and to define the outline of the enclosed blood volumes on a section by section basis. Images were obtained at 5-mm intervals in patients aged 3 months to 30 years with anomalies of the great vessels, tetralogy of Fallot, septal defects, pulmonary atresia, and other congenital heart malformations. The results were used to facilitate the surgical treatment of these patients and were compared with echocardiographic and cineradiographic studies, and with surgical findings or pathologic specimens. These surface reconstruction images were useful for communicating the results of diagnostic examinations to cardiac surgeons, for sizing and location of intracardiac defects, for imaging the pulmonary venous drainage, and for assessing regional and global function

  4. Development of a robust and cost-effective 3D respiratory motion monitoring system using the kinect device: Accuracy comparison with the conventional stereovision navigation system.

    Science.gov (United States)

    Bae, Myungsoo; Lee, Sangmin; Kim, Namkug

    2018-07-01

    To develop and validate a robust and cost-effective 3D respiratory monitoring system based on a Kinect device with a custom-made simple marker. A 3D respiratory monitoring system comprising the simple marker and the Microsoft Kinect v2 device was developed. The marker was designed for simple and robust detection, and the tracking algorithm was developed using the depth, RGB, and infra-red images acquired from the Kinect sensor. A Kalman filter was used to suppress movement noises. The major movements of the marker attached to the four different locations of body surface were determined from the initially collected tracking points of the marker while breathing. The signal level of respiratory motion with the tracking point was estimated along the major direction vector. The accuracy of the results was evaluated through a comparison with those of the conventional stereovision navigation system (NDI Polaris Spectra). Sixteen normal volunteers were enrolled to evaluate the accuracy of this system. The correlation coefficients between the respiratory motion signal from the Kinect device and conventional navigation system ranged from 0.970 to 0.999 and from 0.837 to 0.995 at the abdominal and thoracic surfaces, respectively. The respiratory motion signal from this system was obtained at 27-30 frames/s. This system with the Kinect v2 device and simple marker could be used for cost-effective, robust and accurate 3D respiratory motion monitoring. In addition, this system is as reliable for respiratory motion signal generation and as practically useful as the conventional stereovision navigation system and is less sensitive to patient posture. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Multimodality cranial image fusion using external markers applied via a vacuum mouthpiece and a case report

    International Nuclear Information System (INIS)

    Sweeney, R.A.; Seydl, K.; Lukas, P.; Bale, R.J.; Trieb, T.; Moncayo, R.; Donnemiller, E.; Eisner, W.; Burtscher, J.; Stockhammer, G.

    2003-01-01

    Purpose: To present a simple and precise method of combining functional information of cranial SPECT and PET images with CT and MRI, in any combination. Material and Methods: Imaging is performed with a hockey mask-like reference frame with image modality-specific markers in precisely defined positions. This frame is reproducibly connected to the VBH vacuum mouthpiece, granting objectively identical repositioning of the frame with respect to the cranium. Using these markers, the desired 3-D imaging modalities can then be manually or automatically registered. This information can be used for diagnosis, treatment planning, and evaluation of follow-up, while the same vacuum mouthpiece allows precisely reproducible stereotactic head fixation during radiotherapy. Results: 244 CT and MR data sets of 49 patients were registered to a root square mean error (RSME) of 0.9 mm (mean). 64 SPECT-CT fusions on 18 of these patients gave an RMSE of 1.4 mm, and 40 PET-CT data sets of eight patients were registered to 1.3 mm. An example of the method is given by means of a case report of a 52-year-old patient with bilateral optic nerve meningioma. Conclusion: This technique is a simple, objective and accurate registration tool to combine diagnosis, treatment planning, treatment, and follow-up, all via an individualized vacuum mouthpiece. Especially for low-resolution PET and even more so for some very diffuse SPECT data sets, activity can now be accurately correlated to anatomic structures. (orig.)

  6. 3D surface reconstruction using optical flow for medical imaging

    International Nuclear Information System (INIS)

    Weng, Nan; Yang, Yee-Hong; Pierson, R.

    1996-01-01

    The recovery of a 3D model from a sequence of 2D images is very useful in medical image analysis. Image sequences obtained from the relative motion between the object and the camera or the scanner contain more 3D information than a single image. Methods to visualize the computed tomograms can be divided into two approaches: the surface rendering approach and the volume rendering approach. A new surface rendering method using optical flow is proposed. Optical flow is the apparent motion in the image plane produced by the projection of the real 3D motion onto 2D image. In this paper, the object remains stationary while the scanner undergoes translational motion. The 3D motion of an object can be recovered from the optical flow field using additional constraints. By extracting the surface information from 3D motion, it is possible to get an accurate 3D model of the object. Both synthetic and real image sequences have been used to illustrate the feasibility of the proposed method. The experimental results suggest that the proposed method is suitable for the reconstruction of 3D models from ultrasound medical images as well as other computed tomograms

  7. Image simulation and assessment of the colour and spatial capabilities of the Colour and Stereo Surface Imaging System (CaSSIS) on the ExoMars Trace Gas Orbiter

    Science.gov (United States)

    Tornabene, Livio L.; Seelos, Frank P.; Pommerol, Antoine; Thomas, Nicolas; Caudill, Christy M.; Becerra, Patricio; Bridges, John C.; Byrne, Shane; Cardinale, Marco; Chojnacki, Matthew; Conway, Susan J.; Cremonese, Gabriele; Dundas, Colin M.; El-Maarry, M. R.; Fernando, Jennifer; Hansen, Candice J.; Hansen, Kayle; Harrison, Tanya N.; Henson, Rachel; Marinangeli, Lucia; McEwen, Alfred S.; Pajola, Maurizio; Sutton, Sarah S.; Wray, James J.

    2018-01-01

    This study aims to assess the spatial and visible/near-infrared (VNIR) colour/spectral capabilities of the 4-band Colour and Stereo Surface Imaging System (CaSSIS) aboard the ExoMars 2016 Trace Grace Orbiter (TGO). The instrument response functions for the CaSSIS imager was used to resample spectral libraries, modelled spectra and to construct spectrally (i.e., in I/F space) and spatially consistent simulated CaSSIS image cubes of various key sites of interest and for ongoing scientific investigations on Mars. Coordinated datasets from Mars Reconnaissance Orbiter (MRO) are ideal, and specifically used for simulating CaSSIS. The Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) provides colour information, while the Context Imager (CTX), and in a few cases the High-Resolution Imaging Science Experiment (HiRISE), provides the complementary spatial information at the resampled CaSSIS unbinned/unsummed pixel resolution (4.6 m/pixel from a 400-km altitude). The methodology used herein employs a Gram-Schmidt spectral sharpening algorithm to combine the ∼18–36 m/pixel CRISM-derived CaSSIS colours with I/F images primarily derived from oversampled CTX images. One hundred and eighty-one simulated CaSSIS 4-colour image cubes (at 18–36 m/pixel) were generated (including one of Phobos) based on CRISM data. From these, thirty-three “fully”-simulated image cubes of thirty unique locations on Mars (i.e., with 4 colour bands at 4.6 m/pixel) were made. All simulated image cubes were used to test both the colour capabilities of CaSSIS by producing standard colour RGB images, colour band ratio composites (CBRCs) and spectral parameters. Simulated CaSSIS CBRCs demonstrated that CaSSIS will be able to readily isolate signatures related to ferrous (Fe2+) iron- and ferric (Fe3+) iron-bearing deposits on the surface of Mars, ices and atmospheric phenomena. Despite the lower spatial resolution of CaSSIS when compared to HiRISE, the results of this work demonstrate that

  8. Roughness based perceptual analysis towards digital skin imaging system with haptic feedback.

    Science.gov (United States)

    Kim, K

    2016-08-01

    To examine psoriasis or atopic eczema, analyzing skin roughness by palpation is essential to precisely diagnose skin diseases. However, optical sensor based skin imaging systems do not allow dermatologists to touch skin images. To solve the problem, a new haptic rendering technology that can accurately display skin roughness must be developed. In addition, the rendering algorithm must be able to filter spatial noises created during 2D to 3D image conversion without losing the original roughness on the skin image. In this study, a perceptual way to design a noise filter that will remove spatial noises and in the meantime recover maximized roughness is introduced by understanding human sensitivity on surface roughness. A visuohaptic rendering system that can provide a user with seeing and touching digital skin surface roughness has been developed including a geometric roughness estimation method from a meshed surface. In following, a psychophysical experiment was designed and conducted with 12 human subjects to measure human perception with the developed visual and haptic interfaces to examine surface roughness. From the psychophysical experiment, it was found that touch is more sensitive at lower surface roughness, and vice versa. Human perception with both senses, vision and touch, becomes less sensitive to surface distortions as roughness increases. When interact with both channels, visual and haptic interfaces, the performance to detect abnormalities on roughness is greatly improved by sensory integration with the developed visuohaptic rendering system. The result can be used as a guideline to design a noise filter that can perceptually remove spatial noises while recover maximized roughness values from a digital skin image obtained by optical sensors. In addition, the result also confirms that the developed visuohaptic rendering system can help dermatologists or skin care professionals examine skin conditions by using vision and touch at the same time. © 2015

  9. Different culture media affect growth characteristics, surface marker distribution and chondrogenic differentiation of human bone marrow-derived mesenchymal stromal cells.

    Science.gov (United States)

    Hagmann, Sebastien; Moradi, Babak; Frank, Sebastian; Dreher, Thomas; Kämmerer, Peer Wolfgang; Richter, Wiltrud; Gotterbarm, Tobias

    2013-07-30

    Bone marrow-derived mesenchymal stromal cells (BM-MSCs) play an important role in modern tissue engineering, while distinct variations of culture media compositions and supplements have been reported. Because MSCs are heterogeneous regarding their regenerative potential and their surface markers, these parameters were compared in four widely used culture media compositions. MSCs were isolated from bone marrow and expanded in four established cell culture media. MSC yield/1000 MNCs, passage time and growth index were observed. In P4, typical MSC surface markers were analysed by fluorescence cytometry. Additionally, chondrogenic, adipogenic and osteogenic differentiation potential were evaluated. Growth index and P0 cell yield varied importantly between the media. The different expansion media had a significant influence on the expression of CD10, CD90, CD105, CD140b CD146 and STRO-1. While no significant differences were observed regarding osteogenic and adipogenic differentiation, chondrogenic differentiation was superior in medium A as reflected by GAG/DNA content. The choice of expansion medium can have a significant influence on growth, differentiation potential and surface marker expression of mesenchymal stromal cells, which is of fundamental importance for tissue engineering procedures.

  10. Visualization of brain surface structures by weighted summation technique using multislice MR images

    International Nuclear Information System (INIS)

    Machida, Yoshio; Hatanaka, Masahiko; Hagiwara, Masayuki; Sugimoto, Hiroshi; Yoshida, Tadatoki; Katada, Kazuhiro.

    1991-01-01

    Surface anatomy scanning (SAS) technique which visualizes brain surface structures has been developed since 1987. In this paper, we propose a modified method called 'multislice SAS', which also generates such surface structure images, and has several advantages compared with conventional SAS technique. The conventional SAS technique uses a very long echo time sequence (e.g. SE(3000, 250)) with a thick slice and a surface coil to enhance CSF on the brain surface. Our modified technique also uses a long echo time sequence. But, added multislice images, each appropriately weighted, are used in stead of a thick slice and a surface coil. Our basic studies have shown that this modified method has the following advantage: Several surface images with slightly different summation directions are obtained, and they are used for stereographic display and cine display. This is very useful for visualizing the spatial relationship of brain surface structures. By choosing appropriate weighting, we can obtain clinically legible surface images. This technique dose not require a surface coil. It means that flexibility of selecting imaging direction is high. We can make a lot of modifications, because the original multislice images of weighted summation are arbitrary. And we also clarify some limitation or disadvantage of this modified method. In conclusion, we think that this technique is one of the practical approaches for surface anatomy imaging. (author)

  11. Generating color terrain images in an emergency response system

    International Nuclear Information System (INIS)

    Belles, R.D.

    1985-08-01

    The Atmospheric Release Advisory Capability (ARAC) provides real-time assessments of the consequences resulting from an atmospheric release of radioactive material. In support of this operation, a system has been created which integrates numerical models, data acquisition systems, data analysis techniques, and professional staff. Of particular importance is the rapid generation of graphical images of the terrain surface in the vicinity of the accident site. A terrain data base and an associated acquisition system have been developed that provide the required terrain data. This data is then used as input to a collection of graphics programs which create and display realistic color images of the terrain. The graphics system currently has the capability of generating color shaded relief images from both overhead and perspective viewpoints within minutes. These images serve to quickly familiarize ARAC assessors with the terrain near the release location, and thus permit them to make better informed decisions in modeling the behavior of the released material. 7 refs., 8 figs

  12. Development of a biosensor microarray towards food screening using imaging surface plasmon resonance

    NARCIS (Netherlands)

    Rebe, S.; Bremer, M.G.E.G.; Giesbers, M.; Norde, W.

    2008-01-01

    In this study we examined the possibilities of implementing direct and competitive immunoassay formats for small and large molecule detection on a microarray, using IBIS imaging surface plasmon resonance (iSPR) system. First, IBIS iSPR optics performance was evaluated. Using a glycerol calibration

  13. Development of a biosensor microarray towards food screening, using imaging surface plasmon resonance

    NARCIS (Netherlands)

    Raz, Sabina Rebe; Bremer, Maria G. E. G.; Giesbers, Marcel; Norde, Willem

    2008-01-01

    In this study we examined the possibilities of implementing direct and competitive immunoassay formats for small and large molecule detection on a microarray, using IBIS imaging surface plasmon resonance (iSPR) system. First, IBIS iSPR optics performance was evaluated. Using a glycerol calibration

  14. [The Role of Imaging in Central Nervous System Infections].

    Science.gov (United States)

    Yokota, Hajime; Tazoe, Jun; Yamada, Kei

    2015-07-01

    Many infections invade the central nervous system. Magnetic resonance imaging (MRI) is the main tool that is used to evaluate infectious lesions of the central nervous system. The useful sequences on MRI are dependent on the locations, such as intra-axial, extra-axial, and spinal cord. For intra-axial lesions, besides the fundamental sequences, including T1-weighted images, T2-weighted images, and fluid-attenuated inversion recovery (FLAIR) images, advanced sequences, such as diffusion-weighted imaging, diffusion tensor imaging, susceptibility-weighted imaging, and MR spectroscopy, can be applied. They are occasionally used as determinants for quick and correct diagnosis. For extra-axial lesions, understanding the differences among 2D-conventional T1-weighted images, 2D-fat-saturated T1-weighted images, 3D-Spin echo sequences, and 3D-Gradient echo sequence after the administration of gadolinium is required to avoid wrong interpretations. FLAIR plus gadolinium is a useful tool for revealing abnormal enhancement on the brain surface. For the spinal cord, the sequences are limited. Evaluating the distribution and time course of the spinal cord are essential for correct diagnoses. We summarize the role of imaging in central nervous system infections and show the pitfalls, key points, and latest information in them on clinical practices.

  15. Early detection of tumor masses by in vivo hematoporphyrin-mediated fluorescence imaging

    International Nuclear Information System (INIS)

    Autiero, Maddalena; Celentano, Luigi; Cozzolino, Rosanna; Laccetti, Paolo; Marotta, Marcello; Mettivier, Giovanni; Cristina Montesi, Maria; Quarto, Maria; Riccio, Patrizia; Roberti, Giuseppe; Russo, Paolo

    2007-01-01

    We investigated the capability of fluorescence reflectance imaging (FRI) for the early detection of surface tumors in mice. We used a hematoporphyrin (HP) compound (HP dichlorohydrate) as a red fluorescent marker and a low noise, high sensitivity, digital CCD camera for fluorescence imaging. In this preliminary study, highly malignant anaplastic human thyroid carcinoma cells were implanted subcutaneously in one mouse and their growth was monitored daily for 5 days by FRI. The selective HP uptake by the tumor tissues was successfully observed: we observed the fluorescence of tumor only 3 days after cancer cells injection, i.e. when the tumor mass was neither visible (to the naked eye) or palpable. These measurements indicate that FRI is a suitable technique to detect minute subcutaneous tumor masses. This FRI system will be coupled to a radionuclide imaging system based on a CdTe detector for in vivo multimodal imaging in mice

  16. High precision bladder cancer irradiation by integrating a library planning procedure of 6 prospectively generated SIB IMRT plans with image guidance using lipiodol markers

    International Nuclear Information System (INIS)

    Meijer, Gert Johan; Toorn, Peter-Paul van der; Bal, Matthieu; Schuring, Danny; Weterings, Jan; Wildt, Michel de

    2012-01-01

    Purpose: To increase local control and decrease side effects for urinary bladder cancer patients by integrating a library planning procedure with image guidance using lipiodol markers. Methods and materials: Twenty patients with T2-T4N0M0 grade 2–3 invasive bladder carcinoma were treated according to an online adaptive protocol. Initially, the gross tumour volume (GTV) was demarcated during cystoscopy by injecting several drops of lipiodol in the submucosa around the tumour. Subsequently two CT scans were acquired with a full bladder and a voided bladder. On both scans, the boost volume (GTV) and the low-risk bladder volume were delineated. Using an interpolation tool, six concomitant boost IMRT plans with increasing bladder volumes were generated. For each fraction the procedure at the treatment unit was as follows: Firstly, a ConeBeam-CT was acquired and based on the amount of bladder filling the best fitting bladder contours and corresponding GTV and IMRT plans were selected. Secondly, the lipiodol markers were registered using the corresponding GTV contours and it was verified that the corresponding 95%-isodose surface covered the entire bladder. Finally, an online setup correction was applied based on this registration and the corresponding treatment plan was irradiated. Results: The lipiodol markers were very useful in outlining the GTV at the planning CT and for daily setup correction. While the patients strived for a full bladder filling at time of the treatment, this was seldom accomplished. Due to our protocol an appropriate plan with adequate coverage of the PTV and without excessive dose to healthy tissue was delivered every day. The treatment was very well tolerated by all patients. At the end of the treatment no grade 3 urinary or gastro-intestinal toxicity was observed. After a median follow-up of 28 months two local relapses occurred. Conclusion: Using the library planning approach combined with online image guidance using lipiodol markers, we

  17. High precision bladder cancer irradiation by integrating a library planning procedure of 6 prospectively generated SIB IMRT plans with image guidance using lipiodol markers.

    Science.gov (United States)

    Meijer, Gert Johan; van der Toorn, Peter-Paul; Bal, Matthieu; Schuring, Danny; Weterings, Jan; de Wildt, Michel

    2012-11-01

    To increase local control and decrease side effects for urinary bladder cancer patients by integrating a library planning procedure with image guidance using lipiodol markers. Twenty patients with T2-T4N0M0 grade 2-3 invasive bladder carcinoma were treated according to an online adaptive protocol. Initially, the gross tumour volume (GTV) was demarcated during cystoscopy by injecting several drops of lipiodol in the submucosa around the tumour. Subsequently two CT scans were acquired with a full bladder and a voided bladder. On both scans, the boost volume (GTV) and the low-risk bladder volume were delineated. Using an interpolation tool, six concomitant boost IMRT plans with increasing bladder volumes were generated. For each fraction the procedure at the treatment unit was as follows: Firstly, a ConeBeam-CT was acquired and based on the amount of bladder filling the best fitting bladder contours and corresponding GTV and IMRT plans were selected. Secondly, the lipiodol markers were registered using the corresponding GTV contours and it was verified that the corresponding 95%-isodose surface covered the entire bladder. Finally, an online setup correction was applied based on this registration and the corresponding treatment plan was irradiated. The lipiodol markers were very useful in outlining the GTV at the planning CT and for daily setup correction. While the patients strived for a full bladder filling at time of the treatment, this was seldom accomplished. Due to our protocol an appropriate plan with adequate coverage of the PTV and without excessive dose to healthy tissue was delivered every day. The treatment was very well tolerated by all patients. At the end of the treatment no grade 3 urinary or gastro-intestinal toxicity was observed. After a median follow-up of 28 months two local relapses occurred. Using the library planning approach combined with online image guidance using lipiodol markers, we were able to deliver a highly conformal dose distribution

  18. Regional quantitative analysis of cortical surface maps of FDG PET images

    CERN Document Server

    Protas, H D; Hayashi, K M; Chin Lung, Yu; Bergsneider, M; Sung Cheng, Huang

    2006-01-01

    Cortical surface maps are advantageous for visualizing the 3D profile of cortical gray matter development and atrophy, and for integrating structural and functional images. In addition, cortical surface maps for PET data, when analyzed in conjunction with structural MRI data allow us to investigate, and correct for, partial volume effects. Here we compared quantitative regional PET values based on a 3D cortical surface modeling approach with values obtained directly from the 3D FDG PET images in various atlas-defined regions of interest (ROIs; temporal, parietal, frontal, and occipital lobes). FDG PET and 3D MR (SPGR) images were obtained and aligned to ICBM space for 15 normal subjects. Each image was further elastically warped in 2D parameter space of the cortical surface, to align major cortical sulci. For each point within a 15 mm distance of the cortex, the value of the PET intensity was averaged to give a cortical surface map of FDG uptake. The average PET values on the cortical surface map were calcula...

  19. Evaluation of Fine Aggregate Morphology by Image Method and Its Effect on Skid-Resistance of Micro-Surfacing.

    Science.gov (United States)

    Xiao, Yue; Wang, Feng; Cui, Peide; Lei, Lei; Lin, Juntao; Yi, Mingwei

    2018-05-29

    Micro-surfacing is a widely used pavement preventive maintenance technology used all over the world, due to its advantages of fast construction, low maintenance cost, good waterproofness, and skid-resistance performance. This study evaluated the fine aggregate morphology and surface texture of micro-surfacing by AIMS (aggregate image measurement system), and explored the effect of aggregate morphology on skid-resistance of single-grade micro-surfacing. Sand patch test and British pendulum test were also used to detect skid-resistance for comparison with the image-based method. Wet abrasion test was used to measure skid-resistance durability for feasibility verification of single-grade micro-surfacing. The results show that the effect of Form2D on the skid-resistance of micro-surfacing is much stronger than that of angularity. Combining the feasibility analysis of durability and skid-resistance, 1.18⁻2.36 grade micro-surfacing meets the requirements of durability and skid-resistance at the same time. This study also determined that, compared with British pendulum test, the texture result obtained by sand patch test fits better with results of image method.

  20. Patient setup aid with wireless CCTV system in radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yang Kyun; Cho, Woong; Park, Jong Min [Seoul National University Graduate School, Seoul (Korea, Republic of); Ha, Sung Whan; Ye, Sung Joon [Seoul National University College of Medicine, Seoul (Korea, Republic of); Park, Suk Won [Chung-Ang University Cellege of Medicine, Seoul (Korea, Republic of); Huh, Soon Nyung [Seoul National University Hospital, Seoul (Korea, Republic of)

    2006-12-15

    To develop a wireless CCTV system in semi-beam's eye view (BEV) to monitor daily patient setup in radiation therapy. In order to get patient images in semi-BEV, CCTV cameras are installed in a custom-made acrylic applicator below the treatment head of a linear accelerator. The images from the cameras are transmitted via radio frequency signal ( {approx} 2.4 GHz and 10 mW RF output). An expected problem with this system is radio frequency interference, which is solved utilizing RF shielding with Cu foils and median filtering software. The images are analyzed by our custom-made software. In the software, three anatomical landmarks in the patient surface are indicated by a user, then automatically the 3 dimensional structures are obtained and registered by utilizing a localization procedure consisting mainly of stereo matching algorithm and Gauss-Newton optimization. This algorithm is applied to phantom images in investigate the setup accuracy. Respiratory gating system is also researched with real-time image processing. A line-laser marker projected on a patient's surface is extracted by binary image processing and the breath pattern is calculated and displayed in real-time. More than 80% of the camera noises from the linear accelerator are eliminated by wrapping the camera with copper foils. The accuracy of the localization procedure is found to be on the order of 1.5 {+-} 0.7 mm with a point phantom and sub-millimeters and degrees with a custom-made head/neck phantom. With line-laser marker, real-time respiratory monitoring is possible in the delay time of {approx} 0.7 sec. The wireless CCTV camera system is the novel tool which can monitor daily patient setups. The feasibility of respiratory gating system with the wireless CCTV is hopeful.

  1. Patient setup aid with wireless CCTV system in radiation therapy

    International Nuclear Information System (INIS)

    Park, Yang Kyun; Cho, Woong; Park, Jong Min; Ha, Sung Whan; Ye, Sung Joon; Park, Suk Won; Huh, Soon Nyung

    2006-01-01

    To develop a wireless CCTV system in semi-beam's eye view (BEV) to monitor daily patient setup in radiation therapy. In order to get patient images in semi-BEV, CCTV cameras are installed in a custom-made acrylic applicator below the treatment head of a linear accelerator. The images from the cameras are transmitted via radio frequency signal ( ∼ 2.4 GHz and 10 mW RF output). An expected problem with this system is radio frequency interference, which is solved utilizing RF shielding with Cu foils and median filtering software. The images are analyzed by our custom-made software. In the software, three anatomical landmarks in the patient surface are indicated by a user, then automatically the 3 dimensional structures are obtained and registered by utilizing a localization procedure consisting mainly of stereo matching algorithm and Gauss-Newton optimization. This algorithm is applied to phantom images in investigate the setup accuracy. Respiratory gating system is also researched with real-time image processing. A line-laser marker projected on a patient's surface is extracted by binary image processing and the breath pattern is calculated and displayed in real-time. More than 80% of the camera noises from the linear accelerator are eliminated by wrapping the camera with copper foils. The accuracy of the localization procedure is found to be on the order of 1.5 ± 0.7 mm with a point phantom and sub-millimeters and degrees with a custom-made head/neck phantom. With line-laser marker, real-time respiratory monitoring is possible in the delay time of ∼ 0.7 sec. The wireless CCTV camera system is the novel tool which can monitor daily patient setups. The feasibility of respiratory gating system with the wireless CCTV is hopeful

  2. Characterization of lipidic markers of chondrogenic differentiation using mass spectrometry imaging.

    Science.gov (United States)

    Rocha, Beatriz; Cillero-Pastor, Berta; Eijkel, Gert; Bruinen, Anne L; Ruiz-Romero, Cristina; Heeren, Ron M A; Blanco, Francisco J

    2015-02-01

    Mesenchymal stem cells (MSC) are an interesting alternative for cell-based therapy of cartilage defects attributable to their capacity to differentiate toward chondrocytes in the process termed chondrogenesis. The metabolism of lipids has recently been associated with the modulation of chondrogenesis and also with the development of pathologies related to cartilage degeneration. Information about the distribution and modulation of lipids during chondrogenesis could provide a panel of putative chondrogenic markers. Thus, the discovery of new lipid chondrogenic markers could be highly valuable for improving MSC-based cartilage therapies. In this work, MS imaging was used to characterize the spatial distribution of lipids in human bone marrow MSCs during the first steps of chondrogenic differentiation. The analysis of MSC micromasses at days 2 and 14 of chondrogenesis by MALDI-MSI led to the identification of 20 different lipid species, including fatty acids, sphingolipids, and phospholipids. Phosphocholine, several sphingomyelins, and phosphatidylcholines were found to increase during the undifferentiated chondrogenic stage. A particularly detected lipid profile was verified by TOF secondary ion MS. Using this technology, a higher intensity of phosphocholine-related ions was observed in the peripheral region of the micromasses collected at day 14. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Cyclops: single-pixel imaging lidar system based on compressive sensing

    Science.gov (United States)

    Magalhães, F.; Correia, M. V.; Farahi, F.; Pereira do Carmo, J.; Araújo, F. M.

    2017-11-01

    Mars and the Moon are envisaged as major destinations of future space exploration missions in the upcoming decades. Imaging LIDARs are seen as a key enabling technology in the support of autonomous guidance, navigation and control operations, as they can provide very accurate, wide range, high-resolution distance measurements as required for the exploration missions. Imaging LIDARs can be used at critical stages of these exploration missions, such as descent and selection of safe landing sites, rendezvous and docking manoeuvres, or robotic surface navigation and exploration. Despite these devices have been commercially available and used for long in diverse metrology and ranging applications, their size, mass and power consumption are still far from being suitable and attractive for space exploratory missions. Here, we describe a compact Single-Pixel Imaging LIDAR System that is based on a compressive sensing technique. The application of the compressive codes to a DMD array enables compression of the spatial information, while the collection of timing histograms correlated to the pulsed laser source ensures image reconstruction at the ranged distances. Single-pixel cameras have been compared with raster scanning and array based counterparts in terms of noise performance, and proved to be superior. Since a single photodetector is used, a better SNR and higher reliability is expected in contrast with systems using large format photodetector arrays. Furthermore, the event of failure of one or more micromirror elements in the DMD does not prevent full reconstruction of the images. This brings additional robustness to the proposed 3D imaging LIDAR. The prototype that was implemented has three modes of operation. Range Finder: outputs the average distance between the system and the area of the target under illumination; Attitude Meter: provides the slope of the target surface based on distance measurements in three areas of the target; 3D Imager: produces 3D ranged

  4. Enclosure for small animals during awake animal imaging

    Science.gov (United States)

    Goddard, Jr., James S

    2013-11-26

    An enclosure or burrow restrains an awake animal during an imaging procedure. A tubular body, made from a radiolucent material that does not attenuate x-rays or gamma rays, accepts an awake animal. A proximal end of the body includes an attachment surface that corresponds to an attachment surface of an optically transparent and optically uniform window. An anti-reflective coating may be applied to an inner surface, an outer surface, or both surfaces of the window. Since the window is a separate element of the enclosure and it is not integrally formed as part of the body, it can be made with optically uniform thickness properties for improved motion tracking of markers on the animal with a camera during the imaging procedure. The motion tracking information is then used to compensate for animal movement in the image.

  5. Improvement in Interobserver Accuracy in Delineation of the Lumpectomy Cavity Using Fiducial Markers

    International Nuclear Information System (INIS)

    Shaikh, Talha; Chen Ting; Khan, Atif; Yue, Ning J.; Kearney, Thomas; Cohler, Alan; Haffty, Bruce G.; Goyal, Sharad

    2010-01-01

    Purpose: To determine, whether the presence of gold fiducial markers would improve the inter- and intraphysician accuracy in the delineation of the surgical cavity compared with a matched group of patients who did not receive gold fiducial markers in the setting of accelerated partial-breast irradiation (APBI). Methods and Materials: Planning CT images of 22 lumpectomy cavities were reviewed in a cohort of 22 patients; 11 patients received four to six gold fiducial markers placed at the time of surgery. Three physicians categorized the seroma cavity according to cavity visualization score criteria and delineated each of the 22 seroma cavities and the clinical target volume. Distance between centers of mass, percentage overlap, and average surface distance for all patients were assessed. Results: The mean seroma volume was 36.9 cm 3 and 34.2 cm 3 for fiducial patients and non-fiducial patients, respectively (p = ns). Fiducial markers improved the mean cavity visualization score, to 3.6 ± 1.0 from 2.5 ± 1.3 (p < 0.05). The mean distance between centers of mass, average surface distance, and percentage overlap for the seroma and clinical target volume were significantly improved in the fiducial marker patients as compared with the non-fiducial marker patients (p < 0.001). Conclusions: The placement of gold fiducial markers placed at the time of lumpectomy improves interphysician identification and delineation of the seroma cavity and clinical target volume. This has implications in radiotherapy treatment planning for accelerated partial-breast irradiation and for boost after whole-breast irradiation.

  6. Spectrally enhanced image resolution of tooth enamel surfaces

    Science.gov (United States)

    Zhang, Liang; Nelson, Leonard Y.; Berg, Joel H.; Seibel, Eric J.

    2012-01-01

    Short-wavelength 405 nm laser illumination of surface dental enamel using an ultrathin scanning fiber endoscope (SFE) produced enhanced detail of dental topography. The surfaces of human extracted teeth and artificial erosions were imaged with 405 nm, 444 nm, 532 nm, or 635 nm illumination lasers. The obtained images were then processed offline to compensate for any differences in the illumination beam diameters between the different lasers. Scattering and absorption coefficients for a Monte Carlo model of light propagation in dental enamel for 405 nm were scaled from published data at 532 nm and 633 nm. The value of the scattering coefficient used in the model was scaled from the coefficients at 532 nm and 633 nm by the inverse third power of wavelength. Simulations showed that the penetration depth of short-wavelength illumination is localized close to the enamel surface, while long-wavelength illumination travels much further and is backscattered from greater depths. Therefore, images obtained using short wavelength laser are not contaminated by the superposition of light reflected from enamel tissue at greater depths. Hence, the SFE with short-wavelength illumination may make it possible to visualize surface manifestations of phenomena such as demineralization, thus better aiding the clinician in the detection of early caries.

  7. Medical imaging systems

    Science.gov (United States)

    Frangioni, John V

    2013-06-25

    A medical imaging system provides simultaneous rendering of visible light and diagnostic or functional images. The system may be portable, and may include adapters for connecting various light sources and cameras in open surgical environments or laparascopic or endoscopic environments. A user interface provides control over the functionality of the integrated imaging system. In one embodiment, the system provides a tool for surgical pathology.

  8. Biochemical markers predictive for bone marrow involvement in systemic mastocytosis

    NARCIS (Netherlands)

    Donker, Marjolein L.; van Doormaal, Jasper J.; van Doormaal, Frederiek F.; Kluin, Philip M.; van der Veer, Eveline; de Monchy, Jan G. R.; Kema, Ido P.; Kluin-Nelemans, Hanneke C.

    Systemic mastocytosis is characterized by bone marrow involvement, which requires a bone marrow biopsy for diagnostic work-up. We questioned whether bone marrow involvement could be predicted using biochemical markers. We selected patients with various symptoms suggestive of indolent systemic

  9. System and method for generating 3D images of non-linear properties of rock formation using surface seismic or surface to borehole seismic or both

    Science.gov (United States)

    Vu, Cung Khac; Nihei, Kurt Toshimi; Johnson, Paul A.; Guyer, Robert A.; Ten Cate, James A.; Le Bas, Pierre-Yves; Larmat, Carene S.

    2016-06-07

    A system and method of characterizing properties of a medium from a non-linear interaction are include generating, by first and second acoustic sources disposed on a surface of the medium on a first line, first and second acoustic waves. The first and second acoustic sources are controllable such that trajectories of the first and second acoustic waves intersect in a mixing zone within the medium. The method further includes receiving, by a receiver positioned in a plane containing the first and second acoustic sources, a third acoustic wave generated by a non-linear mixing process from the first and second acoustic waves in the mixing zone; and creating a first two-dimensional image of non-linear properties or a first ratio of compressional velocity and shear velocity, or both, of the medium in a first plane generally perpendicular to the surface and containing the first line, based on the received third acoustic wave.

  10. MR imaging evaluation of pancreas and hepatobiliary system in cystic fibrosis

    International Nuclear Information System (INIS)

    Murayama, S.; Robinson, A.E.; Stallworth, J.; Mulvihill, D.; Beckerman, R.; Davis, S.

    1988-01-01

    The pancreas and hepatobiliary system of 20 patients with cystic fibrosis were analyzed with a 1.5-T magnet. T1-weighted, T2-weighted, and proton-density images were obtained, and the T1 and T2 values of the pancreas were calculated. Signal intensity ratios were calculated for the signal intensities of the pancreas and the liver relative to that of muscle and fat on each pulse sequence. Fatty replacement of the pancreas and regenerating nodules of biliary cirrhosis were readily identified on T1-weighted images. The T1 values for pancreatic tissue showed promise as a good marker for pancreatic disease progression. Pancreas-to-fat signal intensity ratios on 300/20 (repetition time msec/echo time msec) and 2,000/75 images were considered to be a good standard for evaluating the level of pancreatic involvement

  11. Alternative fiducial markers for Vero real-time tumor tracking radiotherapy: A phantom study

    Science.gov (United States)

    Park, Shin-Hyung; Kim, Jae-Chul; Kim, Sung Joon

    2016-12-01

    The objective of this study was to investigate the feasibility of potential fiducial markers consisting of various materials in a Vero real-time tumor-tracking (RTTT) system. In order to determine the applicability of fiducial markers for the Vero RTTT system, we tested various markers consisting of 8 kinds of material (titanium, stainless steel, high-carbon steel, pure steel, copper, silver, tantalum, and gold) with various diameters ranging from 0.3 mm to 1.6 mm and a length of 5 mm. Additionally, a commercial gold coil marker (Visicoil™, IBA dosimetry, Schwarzenbruck, Germany) of diameter 0.5 mm and length 1 cm was included for evaluation. The radiologic visibility on kV fluoroscopy/kV CT scan images of the fiducial markers was evaluated. The detectability on the RTTT system was tested using a two-dimensional moving phantom (Brainlab AG, Feldkirchen, Germany), producing sinusoidal motion. The target center's accuracy was evaluated by calculating the deviation of the position of a metal sphere from the center on the dose profile. Dose profiles were measured using Gafchromic EBT2 films (International Specialty Products, NJ, USA). All markers were visible on kV fluoroscopy/kV CT while markers with atomic number ≥ 25.7 were detectable on the Vero RTTT system. All the detected markers showed excellent geometric accuracy.

  12. SU-E-J-139: One Institution’s Experience with Surface Imaging in Proton Therapy

    International Nuclear Information System (INIS)

    Zhao, L; Singh, H; Zheng, Y

    2015-01-01

    Purpose: X-ray system is commonly used for IGRT in proton therapy, however image acquisition not only increases treatment time but also adds imaging dose. We studied a 3D surface camera system (AlignRT) performance for proton therapy. Methods: System accuracy was evaluated with rigid phantom under two different camera location configurations. For initial clinical applications, post mastectomy chest wall and partial breast treatments were studied. X-ray alignment was used as our ground truth. Our studies included: 1) comparison of daily patient setup shifts between X-ray alignment and SI calculation; 2) interfractional breast surface position variation when aligning to bony landmark on X-ray; 3) absolute positioning using planning CT DICOM data; 4) shifts for multi-isocenter treatment plan; 5) couch isocentric rotation accuracy. Results: Camera locations affected the system performance. After camera relocation, the accuracy of the system for the rigid phantom was within 1 mm (fixed couch), and 1.5 mm (isocentric rotation). For intrafractional patient positioning, X-ray and AlignRT shifts were highly correlated (r=0.99), with the largest difference (mean ± SD) in the longitudinal direction (2.14 ± 1.02 mm). For interfractional breast surface variation and absolute positioning, there were still larger disagreements between the two modalities due to different focus on anatomical landmarks, and 95% of the data lie within 5mm with some outliers at 7 mm–9 mm. For multi-isocenter shifts, the difference was 1 ± 0.56 mm over an 11 cm shift in longitudinal direction. For couch rotation study, the differences was 1.36 ± 1.0 mm in vertical direction, 3.04 ± 2.11 mm in longitudinal direction, and 2.10 ± 1.66 mm in lateral direction, with all rotation differences < 1.5 degree. Conclusion: Surface imaging is promising for intrafractional treatment application in proton therapy to reduce X-ray frequency. However the interfractional discrepancy between the X-ray and SI

  13. SU-E-J-139: One Institution’s Experience with Surface Imaging in Proton Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, L; Singh, H; Zheng, Y [ProCure Proton Therapy Center, Oklahoma City, OK (United States)

    2015-06-15

    Purpose: X-ray system is commonly used for IGRT in proton therapy, however image acquisition not only increases treatment time but also adds imaging dose. We studied a 3D surface camera system (AlignRT) performance for proton therapy. Methods: System accuracy was evaluated with rigid phantom under two different camera location configurations. For initial clinical applications, post mastectomy chest wall and partial breast treatments were studied. X-ray alignment was used as our ground truth. Our studies included: 1) comparison of daily patient setup shifts between X-ray alignment and SI calculation; 2) interfractional breast surface position variation when aligning to bony landmark on X-ray; 3) absolute positioning using planning CT DICOM data; 4) shifts for multi-isocenter treatment plan; 5) couch isocentric rotation accuracy. Results: Camera locations affected the system performance. After camera relocation, the accuracy of the system for the rigid phantom was within 1 mm (fixed couch), and 1.5 mm (isocentric rotation). For intrafractional patient positioning, X-ray and AlignRT shifts were highly correlated (r=0.99), with the largest difference (mean ± SD) in the longitudinal direction (2.14 ± 1.02 mm). For interfractional breast surface variation and absolute positioning, there were still larger disagreements between the two modalities due to different focus on anatomical landmarks, and 95% of the data lie within 5mm with some outliers at 7 mm–9 mm. For multi-isocenter shifts, the difference was 1 ± 0.56 mm over an 11 cm shift in longitudinal direction. For couch rotation study, the differences was 1.36 ± 1.0 mm in vertical direction, 3.04 ± 2.11 mm in longitudinal direction, and 2.10 ± 1.66 mm in lateral direction, with all rotation differences < 1.5 degree. Conclusion: Surface imaging is promising for intrafractional treatment application in proton therapy to reduce X-ray frequency. However the interfractional discrepancy between the X-ray and SI

  14. Using RAD-seq to recognize sex-specific markers and sex chromosome systems.

    Science.gov (United States)

    Gamble, Tony

    2016-05-01

    Next-generation sequencing methods have initiated a revolution in molecular ecology and evolution (Tautz et al. ). Among the most impressive of these sequencing innovations is restriction site-associated DNA sequencing or RAD-seq (Baird et al. ; Andrews et al. ). RAD-seq uses the Illumina sequencing platform to sequence fragments of DNA cut by a specific restriction enzyme and can generate tens of thousands of molecular genetic markers for analysis. One of the many uses of RAD-seq data has been to identify sex-specific genetic markers, markers found in one sex but not the other (Baxter et al. ; Gamble & Zarkower ). Sex-specific markers are a powerful tool for biologists. At their most basic, they can be used to identify the sex of an individual via PCR. This is useful in cases where a species lacks obvious sexual dimorphism at some or all life history stages. For example, such tests have been important for studying sex differences in life history (Sheldon ; Mossman & Waser ), the management and breeding of endangered species (Taberlet et al. ; Griffiths & Tiwari ; Robertson et al. ) and sexing embryonic material (Hacker et al. ; Smith et al. ). Furthermore, sex-specific markers allow recognition of the sex chromosome system in cases where standard cytogenetic methods fail (Charlesworth & Mank ; Gamble & Zarkower ). Thus, species with male-specific markers have male heterogamety (XY) while species with female-specific markers have female heterogamety (ZW). In this issue, Fowler & Buonaccorsi () illustrate the ease by which RAD-seq data can generate sex-specific genetic markers in rockfish (Sebastes). Moreover, by examining RAD-seq data from two closely related rockfish species, Sebastes chrysomelas and Sebastes carnatus (Fig. ), Fowler & Buonaccorsi () uncover shared sex-specific markers and a conserved sex chromosome system. © 2016 John Wiley & Sons Ltd.

  15. Super-Resolution Imaging of Protein Secretion Systems and the Cell Surface of Gram-Negative Bacteria

    Directory of Open Access Journals (Sweden)

    Sachith D. Gunasinghe

    2017-05-01

    Full Text Available Gram-negative bacteria have a highly evolved cell wall with two membranes composed of complex arrays of integral and peripheral proteins, as well as phospholipids and glycolipids. In order to sense changes in, respond to, and exploit their environmental niches, bacteria rely on structures assembled into or onto the outer membrane. Protein secretion across the cell wall is a key process in virulence and other fundamental aspects of bacterial cell biology. The final stage of protein secretion in Gram-negative bacteria, translocation across the outer membrane, is energetically challenging so sophisticated nanomachines have evolved to meet this challenge. Advances in fluorescence microscopy now allow for the direct visualization of the protein secretion process, detailing the dynamics of (i outer membrane biogenesis and the assembly of protein secretion systems into the outer membrane, (ii the spatial distribution of these and other membrane proteins on the bacterial cell surface, and (iii translocation of effector proteins, toxins and enzymes by these protein secretion systems. Here we review the frontier research imaging the process of secretion, particularly new studies that are applying various modes of super-resolution microscopy.

  16. A real time S-parameter imaging system

    International Nuclear Information System (INIS)

    Naik, P.S.; Cheung, C.K.; Beling, C.D.; Fung, S.

    2005-01-01

    Obtaining a lateral S-parameter image scan from positrons implanted into semiconductor devices can be a helpful research tool both for localizing device structures and in diagnosing defect patterns that could help interpret function. S-parameter images can be obtained by electromagnetically rastering a variable energy positron beam of small spot size across the sample. Here we describe a general hardware and software architecture of relatively low cost that has recently been developed in our laboratory which allows the whole sub-surface S-parameter image of a sample or device to be obtained in real time. This system has the advantage over more conventional sequential scanning techniques of allowing the operator to terminate data collection once the quality of the image is deemed sufficient. As an example of the usefulness of this type of imaging architecture, S-parameter images of a representative sample are presented at two different position implantation energies. (author)

  17. Image formation simulation for computer-aided inspection planning of machine vision systems

    Science.gov (United States)

    Irgenfried, Stephan; Bergmann, Stephan; Mohammadikaji, Mahsa; Beyerer, Jürgen; Dachsbacher, Carsten; Wörn, Heinz

    2017-06-01

    In this work, a simulation toolset for Computer Aided Inspection Planning (CAIP) of systems for automated optical inspection (AOI) is presented along with a versatile two-robot-setup for verification of simulation and system planning results. The toolset helps to narrow down the large design space of optical inspection systems in interaction with a system expert. The image formation taking place in optical inspection systems is simulated using GPU-based real time graphics and high quality off-line-rendering. The simulation pipeline allows a stepwise optimization of the system, from fast evaluation of surface patch visibility based on real time graphics up to evaluation of image processing results based on off-line global illumination calculation. A focus of this work is on the dependency of simulation quality on measuring, modeling and parameterizing the optical surface properties of the object to be inspected. The applicability to real world problems is demonstrated by taking the example of planning a 3D laser scanner application. Qualitative and quantitative comparison results of synthetic and real images are presented.

  18. Chemical imaging and solid state analysis at compact surfaces using UV imaging

    DEFF Research Database (Denmark)

    Wu, Jian X.; Rehder, Sönke; van den Berg, Frans

    2014-01-01

    and excipients in a non-invasive way, as well as mapping the glibenclamide solid state form. An exploratory data analysis supported the critical evaluation of the mapping results and the selection of model parameters for the chemical mapping. The present study demonstrated that the multi-wavelength UV imaging......Fast non-destructive multi-wavelength UV imaging together with multivariate image analysis was utilized to visualize distribution of chemical components and their solid state form at compact surfaces. Amorphous and crystalline solid forms of the antidiabetic compound glibenclamide...

  19. DEVELOPMENT OF EVALUATION OF A QUANTITATIVE VIDEO-FLUORESCENCE IMAGING SYSTEM AND FLUORESCENT TRACER FOR MEASURING TRANSFER OF PESTICIDE RESIDUES FROM SURFACES TO HANDS WITH REPEATED CONTACTS

    Science.gov (United States)

    A video imaging system and the associated quantification methods have been developed for measurement of the transfers of a fluorescent tracer from surfaces to hands. The highly fluorescent compound riboflavin (Vitamin B2), which is also water soluble and non-toxic, was chosen as...

  20. Imaging-based surrogate markers of transcriptome subclasses and signatures in hepatocellular carcinoma. Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Taouli, Bachir [Icahn School of Medicine at Mount Sinai, Department of Radiology, New York, NY (United States); Icahn School of Medicine at Mount Sinai, Translational and Molecular Imaging Institute, New York, NY (United States); Icahn School of Medicine at Mount Sinai, Liver Cancer Program, Tisch Cancer Institute, New York, NY (United States); Hoshida, Yujin; Chen, Xintong; Sun, Xiaochen; Kojima, Kensuke; Toffanin, Sara; Hirschfield, Hadassa [Icahn School of Medicine at Mount Sinai, Liver Cancer Program, Tisch Cancer Institute, New York, NY (United States); Icahn School of Medicine at Mount Sinai, Division of Liver Diseases, Department of Medicine, New York, NY (United States); Kakite, Suguru [Icahn School of Medicine at Mount Sinai, Translational and Molecular Imaging Institute, New York, NY (United States); Tottori University, Division of Radiology, Department of Pathophysiological and Therapeutic Science, Faculty of Medicine, Yonago City (Japan); Tan, Poh Seng [Icahn School of Medicine at Mount Sinai, Liver Cancer Program, Tisch Cancer Institute, New York, NY (United States); Icahn School of Medicine at Mount Sinai, Division of Liver Diseases, Department of Medicine, New York, NY (United States); National University Health System, Division of Gastroenterology and Hepatology, University Medicine Cluster, Singapore (Singapore); Kihira, Shingo [Icahn School of Medicine at Mount Sinai, Department of Radiology, New York, NY (United States); Fiel, M.I. [Icahn School of Medicine at Mount Sinai, Department of Pathology, New York, NY (United States); Wagner, Mathilde [Icahn School of Medicine at Mount Sinai, Translational and Molecular Imaging Institute, New York, NY (United States); Sorbonne Universites, UPMC, Department of Radiology, Hopital Pitie-Salpetriere, Paris (France); Llovet, Josep M. [Icahn School of Medicine at Mount Sinai, Liver Cancer Program, Tisch Cancer Institute, New York, NY (United States); Icahn School of Medicine at Mount Sinai, Division of Liver Diseases, Department of Medicine, New York, NY (United States); Universitat de Barcelona, HCC Translational Research Laboratory, Barcelona-Clinic Liver Cancer Group Institut d' Investigacions Biomediques August Pi i Sunyer (IDIBAPS), Hospital Clinic de Barcelona, Barcelona (Spain); Institucio Catalana de Recerca i Estudis Avancats, Barcelona (Spain)

    2017-11-15

    In this preliminary study, we examined whether imaging-based phenotypes are associated with reported predictive gene signatures in hepatocellular carcinoma (HCC). Thirty-eight patients (M/F 30/8, mean age 61 years) who underwent pre-operative CT or MR imaging before surgery as well as transcriptome profiling were included in this IRB-approved single-centre retrospective study. Eleven qualitative and four quantitative imaging traits (size, enhancement ratios, wash-out ratio, tumour-to-liver contrast ratios) were assessed by three observers and were correlated with 13 previously reported HCC gene signatures using logistic regression analysis. Thirty-nine HCC tumours (mean size 5.7 ± 3.2 cm) were assessed. Significant positive associations were observed between certain imaging traits and gene signatures of aggressive HCC phenotype (G3-Boyault, Proliferation-Chiang profiles, CK19-Villanueva, S1/S2-Hoshida) with odds ratios ranging from 4.44-12.73 (P <0.045). Infiltrative pattern at imaging was significantly associated with signatures of microvascular invasion and aggressive phenotype. Significant but weak associations were also observed between each enhancement ratio and tumour-to-liver contrast ratios and certain gene expression profiles. This preliminary study demonstrates a correlation between phenotypic imaging traits with gene signatures of aggressive HCC, which warrants further prospective validation to establish imaging-based surrogate markers of molecular phenotypes in HCC. (orig.)

  1. Imaging-based surrogate markers of transcriptome subclasses and signatures in hepatocellular carcinoma. Preliminary results

    International Nuclear Information System (INIS)

    Taouli, Bachir; Hoshida, Yujin; Chen, Xintong; Sun, Xiaochen; Kojima, Kensuke; Toffanin, Sara; Hirschfield, Hadassa; Kakite, Suguru; Tan, Poh Seng; Kihira, Shingo; Fiel, M.I.; Wagner, Mathilde; Llovet, Josep M.

    2017-01-01

    In this preliminary study, we examined whether imaging-based phenotypes are associated with reported predictive gene signatures in hepatocellular carcinoma (HCC). Thirty-eight patients (M/F 30/8, mean age 61 years) who underwent pre-operative CT or MR imaging before surgery as well as transcriptome profiling were included in this IRB-approved single-centre retrospective study. Eleven qualitative and four quantitative imaging traits (size, enhancement ratios, wash-out ratio, tumour-to-liver contrast ratios) were assessed by three observers and were correlated with 13 previously reported HCC gene signatures using logistic regression analysis. Thirty-nine HCC tumours (mean size 5.7 ± 3.2 cm) were assessed. Significant positive associations were observed between certain imaging traits and gene signatures of aggressive HCC phenotype (G3-Boyault, Proliferation-Chiang profiles, CK19-Villanueva, S1/S2-Hoshida) with odds ratios ranging from 4.44-12.73 (P <0.045). Infiltrative pattern at imaging was significantly associated with signatures of microvascular invasion and aggressive phenotype. Significant but weak associations were also observed between each enhancement ratio and tumour-to-liver contrast ratios and certain gene expression profiles. This preliminary study demonstrates a correlation between phenotypic imaging traits with gene signatures of aggressive HCC, which warrants further prospective validation to establish imaging-based surrogate markers of molecular phenotypes in HCC. (orig.)

  2. Magnetic resonance imaging in the radiation treatment planning of localized prostate cancer using intra-prostatic fiducial markers for computed tomography co-registration

    International Nuclear Information System (INIS)

    Parker, C.C.; Damyanovich, A.; Haycocks, T.; Haider, M.; Bayley, A.; Catton, C.N.

    2003-01-01

    Purpose: To assess the feasibility, and potential implications, of using intra-prostatic fiducial markers, rather than bony landmarks, for the co-registration of computed tomography (CT) and magnetic resonance (MR) images in the radiation treatment planning of localized prostate cancer. Methods: All men treated with conformal therapy for localized prostate cancer underwent routine pre-treatment insertion of prostatic fiducial markers to assist with gross target volume (GTV) delineation and to identify prostate positioning during therapy. Six of these men were selected for investigation. Phantom MRI measurements were obtained to quantify image distortion, to determine the most suitable gold alloy marker composition, and to identify the spin-echo sequences that optimized both marker identification and the contrast between the prostate and the surrounding tissues. The GTV for each patient was contoured independently by three radiation oncologists on axial planning CT slices, and on axial MRI slices fused to the CT slices by matching the implanted fiducial markers. From each set of contours the scan common volume (SCV), and the scan encompassing volume (SEV), were obtained. The ratio SEV/SCV for a given scan is a measure of inter-observer variation in contouring. For each of the 18 patient-observer combinations the observer common volume (OCV) and the observer encompassing volume (OEV) was obtained. The ratio OEV/OCV for a given patient-observer combination is a measure of the inter-modality variation in contouring. The distance from the treatment planning isocenter to the prostate contours was measured and the discrepancy between the CT- and the MR-defined contour recorded. The discrepancies between the CT- and MR-defined contours of the posterior prostate were recorded in the sagittal plane at 1-cm intervals above and below the isocenter. Results: Phantom measurements demonstrated trivial image distortion within the required field of view, and an 18K Au/Cu alloy to

  3. Method comparison of ultrasound and kilovoltage x-ray fiducial marker imaging for prostate radiotherapy targeting

    International Nuclear Information System (INIS)

    Fuller, Clifton David; Jr, Charles R Thomas; Schwartz, Scott; Golden, Nanalei; Ting, Joe; Wong, Adrian; Erdogmus, Deniz; Scarbrough, Todd J

    2006-01-01

    Several measurement techniques have been developed to address the capability for target volume reduction via target localization in image-guided radiotherapy; among these have been ultrasound (US) and fiducial marker (FM) software-assisted localization. In order to assess interchangeability between methods, US and FM localization were compared using established techniques for determination of agreement between measurement methods when a 'gold-standard' comparator does not exist, after performing both techniques daily on a sequential series of patients. At least 3 days prior to CT simulation, four gold seeds were placed within the prostate. FM software-assisted localization utilized the ExacTrac X-Ray 6D (BrainLab AG, Germany) kVp x-ray image acquisition system to determine prostate position; US prostate targeting was performed on each patient using the SonArray (Varian, Palo Alto, CA). Patients were aligned daily using laser alignment of skin marks. Directional shifts were then calculated by each respective system in the X, Y and Z dimensions before each daily treatment fraction, previous to any treatment or couch adjustment, as well as a composite vector of displacement. Directional shift agreement in each axis was compared using Altman-Bland limits of agreement, Lin's concordance coefficient with Partik's grading schema, and Deming orthogonal bias-weighted correlation methodology. 1019 software-assisted shifts were suggested by US and FM in 39 patients. The 95% limits of agreement in X, Y and Z axes were ±9.4 mm, ±11.3 mm and ±13.4, respectively. Three-dimensionally, measurements agreed within 13.4 mm in 95% of all paired measures. In all axes, concordance was graded as 'poor' or 'unacceptable'. Deming regression detected proportional bias in both directional axes and three-dimensional vectors. Our data suggest substantial differences between US and FM image-guided measures and subsequent suggested directional shifts. Analysis reveals that the vast majority of

  4. Determining Surface Infiltration Rate of Permeable Pavements with Digital Imaging

    Directory of Open Access Journals (Sweden)

    Caterina Valeo

    2018-01-01

    Full Text Available Cell phone images of pervious pavement surfaces were used to explore relationships between surface infiltration rates (SIR measured using the ASTM C1701 standard test and using a simple falling head test. A fiber-reinforced porous asphalt surface and a highly permeable material comprised of stone, rubber and a polymer binder (Porous Pave were tested. Images taken with a high-resolution cellphone camera were acquired as JPEG files and converted to gray scale images in Matlab® for analysis. The distribution of gray levels was compared to the surface infiltration rates obtained for both pavements with attention given to the mean of the distribution. Investigation into the relationships between mean SIR and parameters determined from the gray level distribution produced in the image analysis revealed that mean SIR measured in both pavements were proportional to the inverse of the mean of the distribution. The relationships produced a coefficient of determination over 85% using both the ASTM and the falling head test in the porous asphalt surface. SIR measurements determined with the ASTM method were highly correlated with the inverse mean of the distribution of gray levels in the Porous Pave material as well, producing coefficients of determination of over 90% and Kendall’s tau-b of roughly 70% for nonparametric data.

  5. Application of an Automated Discharge Imaging System and LSPIV during Typhoon Events in Taiwan

    OpenAIRE

    Wei-Che Huang; Chih-Chieh Young; Wen-Cheng Liu

    2018-01-01

    An automated discharge imaging system (ADIS), which is a non-intrusive and safe approach, was developed for measuring river flows during flash flood events. ADIS consists of dual cameras to capture complete surface images in the near and far fields. Surface velocities are accurately measured using the Large Scale Particle Image Velocimetry (LSPIV) technique. The stream discharges are then obtained from the depth-averaged velocity (based upon an empirical velocity-index relationship) and cross...

  6. Simultaneous Microwave Imaging System for Density and Temperature Fluctuation Measurements on TEXTOR

    International Nuclear Information System (INIS)

    Park, H.; Mazzucato, E.; Munsat, T.; Domier, C.W.; Johnson, M.; Luhmann, N.C. Jr.; Wang, J.; Xia, Z.; Classen, I.G.J.; Donne, A.J.H.; Pol, M.J. van de

    2004-01-01

    Diagnostic systems for fluctuation measurements in plasmas have, of necessity, evolved from simple 1-D systems to multi-dimensional systems due to the complexity of the MHD and turbulence physics of plasmas illustrated by advanced numerical simulations. Using the recent significant advancements in millimeter wave imaging technology, Microwave Imaging Reflectometry (MIR) and Electron Cyclotron Emission Imaging (ECEI), simultaneously measuring density and temperature fluctuations, are developed for TEXTOR. The MIR system was installed on TEXTOR and the first experiment was performed in September, 2003. Subsequent MIR campaigns have yielded poloidally resolved spectra and assessments of poloidal velocity. The new 2-D ECE Imaging system (with a total of 128 channels), installed on TEXTOR in December, 2003, successfully captured a true 2-D images of Te fluctuations of m=1 oscillation (''sawteeth'') near the q ∼ 1 surface for the first time

  7. Planetary surface photometry and imaging: progress and perspectives.

    Science.gov (United States)

    Goguen, Jay D

    2014-10-01

    Spacecraft have visited and returned many thousands of images and spectra of all of the planets, many of their moons, several asteroids, and a few comet nuclei during the golden age of planetary exploration. The signal in each pixel of each image or spectral channel is a measurement of the radiance of scattered sunlight into a specific direction. The information on the structure and composition of the surface that is contained in variation of the radiance with scattering geometry and wavelength, including polarization state, has only just begun to be exploited and is the topic of this review. The uppermost surfaces of these bodies are mainly composed of particles that are continuously generated by impacts of micrometeoroids and larger impactors. Models of light scattering by distributions of sizes and irregular shapes of particles and by closely packed particles within a surface are challenging. These are active topics of research where considerable progress has recently been made. We focus on the surfaces of bodies lacking atmospheres.These surfaces are diverse and their morphologies give evidence of their evolution by impacts and resurfacing by a variety of processes including down slope movement and electrostatic transport of particles, gravitational accumulation of debris, volatile outgassing and migration, and magnetospheric interactions. Sampling of scattering geometries and spatial resolution is constrained by spacecraft trajectories. However, the large number of archived images and spectra demand more quantitative interpretation. The scattering geometry dependence of the radiance is underutilized and promises constraints on the compositions and structure of the surface for materials that lack diagnostic wavelength dependence. The general problem is considered in terms of the lunar regolith for which samples have been returned to Earth.

  8. Clinical usefulness of dopamine transporter imaging

    International Nuclear Information System (INIS)

    Kim, Jong Min; Kim, Yu Kyeong; Kim, Sang Eun; Jeon, Beom S.

    2007-01-01

    Imaging of the dopamine transporter (DAT) provides a marker for the integrity of presynaptic nigrostriatal dopaminergic system. DAT density is reduced in Parkinson disease, multiple system atrophy, and progressive supranuclear palsy. In patients with suspicious parkinsonism, normal DAT imaging suggests an alternative diagnosis such as essential tremor, vascular parkinsonism, or drug-induced parkinsonism. DAT imaging is a useful tool to aid clinician's differential diagnosis in parkinsonism

  9. Raster Scan Computer Image Generation (CIG) System Based On Refresh Memory

    Science.gov (United States)

    Dichter, W.; Doris, K.; Conkling, C.

    1982-06-01

    A full color, Computer Image Generation (CIG) raster visual system has been developed which provides a high level of training sophistication by utilizing advanced semiconductor technology and innovative hardware and firmware techniques. Double buffered refresh memory and efficient algorithms eliminate the problem of conventional raster line ordering by allowing the generated image to be stored in a random fashion. Modular design techniques and simplified architecture provide significant advantages in reduced system cost, standardization of parts, and high reliability. The major system components are a general purpose computer to perform interfacing and data base functions; a geometric processor to define the instantaneous scene image; a display generator to convert the image to a video signal; an illumination control unit which provides final image processing; and a CRT monitor for display of the completed image. Additional optional enhancements include texture generators, increased edge and occultation capability, curved surface shading, and data base extensions.

  10. 3D fingerprint imaging system based on full-field fringe projection profilometry

    Science.gov (United States)

    Huang, Shujun; Zhang, Zonghua; Zhao, Yan; Dai, Jie; Chen, Chao; Xu, Yongjia; Zhang, E.; Xie, Lili

    2014-01-01

    As an unique, unchangeable and easily acquired biometrics, fingerprint has been widely studied in academics and applied in many fields over the years. The traditional fingerprint recognition methods are based on the obtained 2D feature of fingerprint. However, fingerprint is a 3D biological characteristic. The mapping from 3D to 2D loses 1D information and causes nonlinear distortion of the captured fingerprint. Therefore, it is becoming more and more important to obtain 3D fingerprint information for recognition. In this paper, a novel 3D fingerprint imaging system is presented based on fringe projection technique to obtain 3D features and the corresponding color texture information. A series of color sinusoidal fringe patterns with optimum three-fringe numbers are projected onto a finger surface. From another viewpoint, the fringe patterns are deformed by the finger surface and captured by a CCD camera. 3D shape data of the finger can be obtained from the captured fringe pattern images. This paper studies the prototype of the 3D fingerprint imaging system, including principle of 3D fingerprint acquisition, hardware design of the 3D imaging system, 3D calibration of the system, and software development. Some experiments are carried out by acquiring several 3D fingerprint data. The experimental results demonstrate the feasibility of the proposed 3D fingerprint imaging system.

  11. Imaging by Electrochemical Scanning Tunneling Microscopy and Deconvolution Resolving More Details of Surfaces Nanomorphology

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov

    observed in high-resolution images of metallic nanocrystallites may be effectively deconvoluted, as to resolve more details of the crystalline morphology (see figure). Images of surface-crystalline metals indicate that more than a single atomic layer is involved in mediating the tunneling current......Upon imaging, electrochemical scanning tunneling microscopy (ESTM), scanning electrochemical micro-scopy (SECM) and in situ STM resolve information on electronic structures and on surface topography. At very high resolution, imaging processing is required, as to obtain information that relates...... to crystallographic-surface structures. Within the wide range of new technologies, those images surface features, the electrochemical scanning tunneling microscope (ESTM) provides means of atomic resolution where the tip participates actively in the process of imaging. Two metallic surfaces influence ions trapped...

  12. Multipurpose Hyperspectral Imaging System

    Science.gov (United States)

    Mao, Chengye; Smith, David; Lanoue, Mark A.; Poole, Gavin H.; Heitschmidt, Jerry; Martinez, Luis; Windham, William A.; Lawrence, Kurt C.; Park, Bosoon

    2005-01-01

    A hyperspectral imaging system of high spectral and spatial resolution that incorporates several innovative features has been developed to incorporate a focal plane scanner (U.S. Patent 6,166,373). This feature enables the system to be used for both airborne/spaceborne and laboratory hyperspectral imaging with or without relative movement of the imaging system, and it can be used to scan a target of any size as long as the target can be imaged at the focal plane; for example, automated inspection of food items and identification of single-celled organisms. The spectral resolution of this system is greater than that of prior terrestrial multispectral imaging systems. Moreover, unlike prior high-spectral resolution airborne and spaceborne hyperspectral imaging systems, this system does not rely on relative movement of the target and the imaging system to sweep an imaging line across a scene. This compact system (see figure) consists of a front objective mounted at a translation stage with a motorized actuator, and a line-slit imaging spectrograph mounted within a rotary assembly with a rear adaptor to a charged-coupled-device (CCD) camera. Push-broom scanning is carried out by the motorized actuator which can be controlled either manually by an operator or automatically by a computer to drive the line-slit across an image at a focal plane of the front objective. To reduce the cost, the system has been designed to integrate as many as possible off-the-shelf components including the CCD camera and spectrograph. The system has achieved high spectral and spatial resolutions by using a high-quality CCD camera, spectrograph, and front objective lens. Fixtures for attachment of the system to a microscope (U.S. Patent 6,495,818 B1) make it possible to acquire multispectral images of single cells and other microscopic objects.

  13. Evaluation of Fine Aggregate Morphology by Image Method and Its Effect on Skid-Resistance of Micro-Surfacing

    Directory of Open Access Journals (Sweden)

    Yue Xiao

    2018-05-01

    Full Text Available Micro-surfacing is a widely used pavement preventive maintenance technology used all over the world, due to its advantages of fast construction, low maintenance cost, good waterproofness, and skid-resistance performance. This study evaluated the fine aggregate morphology and surface texture of micro-surfacing by AIMS (aggregate image measurement system, and explored the effect of aggregate morphology on skid-resistance of single-grade micro-surfacing. Sand patch test and British pendulum test were also used to detect skid-resistance for comparison with the image-based method. Wet abrasion test was used to measure skid-resistance durability for feasibility verification of single-grade micro-surfacing. The results show that the effect of Form2D on the skid-resistance of micro-surfacing is much stronger than that of angularity. Combining the feasibility analysis of durability and skid-resistance, 1.18–2.36 grade micro-surfacing meets the requirements of durability and skid-resistance at the same time. This study also determined that, compared with British pendulum test, the texture result obtained by sand patch test fits better with results of image method.

  14. Development and Performance Evaluation of Image-Based Robotic Waxing System for Detailing Automobiles.

    Science.gov (United States)

    Lin, Chi-Ying; Hsu, Bing-Cheng

    2018-05-14

    Waxing is an important aspect of automobile detailing, aimed at protecting the finish of the car and preventing rust. At present, this delicate work is conducted manually due to the need for iterative adjustments to achieve acceptable quality. This paper presents a robotic waxing system in which surface images are used to evaluate the quality of the finish. An RGB-D camera is used to build a point cloud that details the sheet metal components to enable path planning for a robot manipulator. The robot is equipped with a multi-axis force sensor to measure and control the forces involved in the application and buffing of wax. Images of sheet metal components that were waxed by experienced car detailers were analyzed using image processing algorithms. A Gaussian distribution function and its parameterized values were obtained from the images for use as a performance criterion in evaluating the quality of surfaces prepared by the robotic waxing system. Waxing force and dwell time were optimized using a mathematical model based on the image-based criterion used to measure waxing performance. Experimental results demonstrate the feasibility of the proposed robotic waxing system and image-based performance evaluation scheme.

  15. Multiple interpretations of a pair of images of a surface

    Science.gov (United States)

    Longuet-Higgins, H. C.

    1988-07-01

    It is known that, if two optical images of a visually textured surface, projected from finitely separated viewpoints, allow more than one three-dimensional interpretation, then the surface must be part of a quadric passing through the two viewpoints. It is here shown that this quadric is either a plane or a ruled surface of a type first considered by Maybank (1985) in a study of ambiguous optic flow fields. In the latter case, three is the maximum number of distinct interpretations that the two images can sustain.

  16. Imaging near-surface heterogeneities by natural migration of backscattered surface waves: Field data test

    KAUST Repository

    Liu, Zhaolun; AlTheyab, Abdullah; Hanafy, Sherif M.; Schuster, Gerard T.

    2017-01-01

    We have developed a methodology for detecting the presence of near-surface heterogeneities by naturally migrating backscattered surface waves in controlled-source data. The near-surface heterogeneities must be located within a depth of approximately one-third the dominant wavelength λ of the strong surface-wave arrivals. This natural migration method does not require knowledge of the near-surface phase-velocity distribution because it uses the recorded data to approximate the Green’s functions for migration. Prior to migration, the backscattered data are separated from the original records, and the band-passed filtered data are migrated to give an estimate of the migration image at a depth of approximately one-third λ. Each band-passed data set gives a migration image at a different depth. Results with synthetic data and field data recorded over known faults validate the effectiveness of this method. Migrating the surface waves in recorded 2D and 3D data sets accurately reveals the locations of known faults. The limitation of this method is that it requires a dense array of receivers with a geophone interval less than approximately one-half λ.

  17. Imaging near-surface heterogeneities by natural migration of backscattered surface waves: Field data test

    KAUST Repository

    Liu, Zhaolun

    2017-03-06

    We have developed a methodology for detecting the presence of near-surface heterogeneities by naturally migrating backscattered surface waves in controlled-source data. The near-surface heterogeneities must be located within a depth of approximately one-third the dominant wavelength λ of the strong surface-wave arrivals. This natural migration method does not require knowledge of the near-surface phase-velocity distribution because it uses the recorded data to approximate the Green’s functions for migration. Prior to migration, the backscattered data are separated from the original records, and the band-passed filtered data are migrated to give an estimate of the migration image at a depth of approximately one-third λ. Each band-passed data set gives a migration image at a different depth. Results with synthetic data and field data recorded over known faults validate the effectiveness of this method. Migrating the surface waves in recorded 2D and 3D data sets accurately reveals the locations of known faults. The limitation of this method is that it requires a dense array of receivers with a geophone interval less than approximately one-half λ.

  18. Normal appearance of the prostate and seminal tract: MR imaging using an endorectal surface coil

    International Nuclear Information System (INIS)

    Kim, Myeong Jin; Lee, Jong Tae; Lee, Moo Sang; Choi, Pil Sik; Hong, Sung Joon; Lee, Yeon Hee; Choi, Hak Yong

    1994-01-01

    To assess the ability of MR imaging with an endorectal surface coil for the depiction of normal anatomical structure of prostate and its adjacent organs. MR imaging using an endorectal surface coil was performed in 23 male patients(age ; 20-75) to evaluate various prostatic and vasovesicular disorders, i. e, 14 cases of ejaculatory problems, 3 cases of hypogonadism, and 4 cases of prostatic cancers and 2 cases of benign prostatic hyperplasia. MR images were obtained with axial, sagittal and coronal fast spin echo long TR/TE images and axial spin echo short TR/TE images. Field of views was 10-12 cm and scan thickness was 3-5 mm. Depiction of normal anatomcial structures was excellent in all cases. On T2WI, zonal anatomy of the prostate and prostatic urethra, urethral crest, and ejaculatory duct were cleary visualized. On T1WI, periprostatic fat plane is more cleary visualized. On transverse images, periprostatic structures were well visualized on T1WI,and on T2WI, anterior fibromuscular stroma, transition zone and peripheral zone could be readily differentiated. Coronal images were more helpful in visualization of both central and peripheral zones. Vas deferens, ejaculatory duct and vermontanum were also more easily defined on these images. Sagittal images was helpful in the depiction of anterior fibromuscular stroma, central zone and peripheral zone with prostatic urethra and ejaculatory duct in a single plane. High resolution MR imaging with an endorectal surface coil can readily visualize the normal anatomy of the prostate and its related structures and may be useful in the evaluation of various diseases of prostate and vasvesicular system

  19. Normal appearance of the prostate and seminal tract: MR imaging using an endorectal surface coil

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myeong Jin; Lee, Jong Tae; Lee, Moo Sang; Choi, Pil Sik; Hong, Sung Joon; Lee, Yeon Hee; Choi, Hak Yong [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1994-06-15

    To assess the ability of MR imaging with an endorectal surface coil for the depiction of normal anatomical structure of prostate and its adjacent organs. MR imaging using an endorectal surface coil was performed in 23 male patients(age ; 20-75) to evaluate various prostatic and vasovesicular disorders, i. e, 14 cases of ejaculatory problems, 3 cases of hypogonadism, and 4 cases of prostatic cancers and 2 cases of benign prostatic hyperplasia. MR images were obtained with axial, sagittal and coronal fast spin echo long TR/TE images and axial spin echo short TR/TE images. Field of views was 10-12 cm and scan thickness was 3-5 mm. Depiction of normal anatomcial structures was excellent in all cases. On T2WI, zonal anatomy of the prostate and prostatic urethra, urethral crest, and ejaculatory duct were cleary visualized. On T1WI, periprostatic fat plane is more cleary visualized. On transverse images, periprostatic structures were well visualized on T1WI,and on T2WI, anterior fibromuscular stroma, transition zone and peripheral zone could be readily differentiated. Coronal images were more helpful in visualization of both central and peripheral zones. Vas deferens, ejaculatory duct and vermontanum were also more easily defined on these images. Sagittal images was helpful in the depiction of anterior fibromuscular stroma, central zone and peripheral zone with prostatic urethra and ejaculatory duct in a single plane. High resolution MR imaging with an endorectal surface coil can readily visualize the normal anatomy of the prostate and its related structures and may be useful in the evaluation of various diseases of prostate and vasvesicular system.

  20. Impulse radar imaging system for concealed object detection

    Science.gov (United States)

    Podd, F. J. W.; David, M.; Iqbal, G.; Hussain, F.; Morris, D.; Osakue, E.; Yeow, Y.; Zahir, S.; Armitage, D. W.; Peyton, A. J.

    2013-10-01

    Electromagnetic systems for imaging concealed objects at checkpoints typically employ radiation at millimetre and terahertz frequencies. These systems have been shown to be effective and provide a sufficiently high resolution image. However there are difficulties and current electromagnetic systems have limitations particularly in accurately differentiating between threat and innocuous objects based on shape, surface emissivity or reflectivity, which are indicative parameters. In addition, water has a high absorption coefficient at millimetre wavelength and terahertz frequencies, which makes it more difficult for these frequencies to image through thick damp clothing. This paper considers the potential of using ultra wideband (UWB) in the low gigahertz range. The application of this frequency band to security screening appears to be a relatively new field. The business case for implementing the UWB system has been made financially viable by the recent availability of low-cost integrated circuits operating at these frequencies. Although designed for the communication sector, these devices can perform the required UWB radar measurements as well. This paper reports the implementation of a 2 to 5 GHz bandwidth linear array scanner. The paper describes the design and fabrication of transmitter and receiver antenna arrays whose individual elements are a type of antipodal Vivaldi antenna. The antenna's frequency and angular response were simulated in CST Microwave Studio and compared with laboratory measurements. The data pre-processing methods of background subtraction and deconvolution are implemented to improve the image quality. The background subtraction method uses a reference dataset to remove antenna crosstalk and room reflections from the dataset. The deconvolution method uses a Wiener filter to "sharpen" the returned echoes which improves the resolution of the reconstructed image. The filter uses an impulse response reference dataset and a signal

  1. Establishment of the method of surface shaded display for brain PET imaging

    International Nuclear Information System (INIS)

    Zhang Xiangsong; Tang Anwu; He Zuoxiang

    2003-01-01

    Objective: To establish the method of surface shaded display (SSD) for brain PET imaging. Methods: The original brain PET images volume data were transferred to the personal computer by the local area network, and scaled into 256 grayscale values between 0 and 255. An appropriate threshold could be selected with three differential methods: depended on the histogram or maximum percentage of the volume data and the opposite value percentage of the lesion. The list of vertices and triangles describing the contour surface was produced with a high resolution three dimensional (3D) surface construction algorithm. Results: The final software of SSD for brain PET imaging with interactive user interface can produce 3D brain PET images which can be rotated, scaled, and saved or outputted with several image formats. Conclusion: The method of SSD for brain PET imaging can directly and integrally reflect the surface of brain cortex, and be helpful to locate lesions and display the range of lesions, but can not reflect the severity of lesions, nor can display the structure under brain cortex

  2. Adaptive fringe-pattern projection for image saturation avoidance in 3D surface-shape measurement.

    Science.gov (United States)

    Li, Dong; Kofman, Jonathan

    2014-04-21

    In fringe-projection 3D surface-shape measurement, image saturation results in incorrect intensities in captured images of fringe patterns, leading to phase and measurement errors. An adaptive fringe-pattern projection (AFPP) method was developed to adapt the maximum input gray level in projected fringe patterns to the local reflectivity of an object surface being measured. The AFPP method demonstrated improved 3D measurement accuracy by avoiding image saturation in highly-reflective surface regions while maintaining high intensity modulation across the entire surface. The AFPP method can avoid image saturation and handle varying surface reflectivity, using only two prior rounds of fringe-pattern projection and image capture to generate the adapted fringe patterns.

  3. Development of gamma-photon/Cerenkov-light hybrid system for simultaneous imaging of I-131 radionuclide

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Seiichi; Suzuki, Mayumi; Kato, Katsuhiko [Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine (Japan); Watabe, Tadashi; Ikeda, Hayato; Kanai, Yasukazu [Department of Molecular Imaging in Medicine, Osaka University Graduate School of Medicine (Japan); Ogata, Yoshimune [Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine (Japan); Hatazawa, Jun [Department of Molecular Imaging in Medicine, Osaka University Graduate School of Medicine (Japan)

    2016-09-11

    Although iodine 131 (I-131) is used for radionuclide therapy, high resolution images are difficult to obtain with conventional gamma cameras because of the high energy of I-131 gamma photons (364 keV). Cerenkov-light imaging is a possible method for beta emitting radionuclides, and I-131 (606 MeV maximum beta energy) is a candidate to obtain high resolution images. We developed a high energy gamma camera system for I-131 radionuclide and combined it with a Cerenkov-light imaging system to form a gamma-photon/Cerenkov-light hybrid imaging system to compare the simultaneously measured images of these two modalities. The high energy gamma imaging detector used 0.85-mm×0.85-mm×10-mm thick GAGG scintillator pixels arranged in a 44×44 matrix with a 0.1-mm thick reflector and optical coupled to a Hamamatsu 2 in. square position sensitive photomultiplier tube (PSPMT: H12700 MOD). The gamma imaging detector was encased in a 2 cm thick tungsten shield, and a pinhole collimator was mounted on its top to form a gamma camera system. The Cerenkov-light imaging system was made of a high sensitivity cooled CCD camera. The Cerenkov-light imaging system was combined with the gamma camera using optical mirrors to image the same area of the subject. With this configuration, we simultaneously imaged the gamma photons and the Cerenkov-light from I-131 in the subjects. The spatial resolution and sensitivity of the gamma camera system for I-131 were respectively ~3 mm FWHM and ~10 cps/MBq for the high sensitivity collimator at 10 cm from the collimator surface. The spatial resolution of the Cerenkov-light imaging system was 0.64 mm FWHM at 10 cm from the system surface. Thyroid phantom and rat images were successfully obtained with the developed gamma-photon/Cerenkov-light hybrid imaging system, allowing direct comparison of these two modalities. Our developed gamma-photon/Cerenkov-light hybrid imaging system will be useful to evaluate the advantages and disadvantages of these two

  4. Prostate position relative to pelvic bony anatomy based on intraprostatic gold markers and electronic portal imaging

    International Nuclear Information System (INIS)

    Schallenkamp, John M.; Herman, Michael G.; Kruse, Jon J.; Pisansky, Thomas M.

    2005-01-01

    Purpose: To describe the relative positions and motions of the prostate, pelvic bony anatomy, and intraprostatic gold fiducial markers during daily electronic portal localization of the prostate. Methods and Materials: Twenty prostate cancer patients were treated supine with definitive external radiotherapy according to an on-line target localization protocol using three or four intraprostatic gold fiducial markers and an electronic portal imaging device. Daily pretherapy and through-treatment electronic portal images (EPIs) were obtained for each of four treatment fields. The patients' pelvic bony anatomy, intraprostatic gold markers, and a best visual match to the target (i.e., prostate) were identified on simulation digitally reconstructed radiographs and during daily treatment setup and delivery. These data provided quantitative inter- and intrafractional analysis of prostate motion, its position relative to the bony anatomy, and the individual intraprostatic fiducial markers. Treatment planning margins, with and without on-line localization, were subsequently compared. Results: A total of 22,266 data points were obtained from daily pretherapy and through-treatment EPIs. The pretherapy three-dimensional (3D) average displacement of the fiducial markers, as a surrogate for the prostate, was 5.6 mm, which improved to 2.8 mm after use of the localization protocol. The bony anatomy 3D average displacement was 4.4 mm both before and after localization to the prostate (p = 0.46). Along the superior-inferior (SI), anterior-posterior (AP), and right-left (RL) axes, the average prostate displacement improved from 2.5, 3.7, and 1.9 mm, respectively, before localization to 1.4, 1.6, and 1.1 mm after (all p < 0.001). The pretherapy to through-treatment position of the bony landmarks worsened from 1.7 to 2.5 mm (p < 0.001) in the SI axis, remained statistically unchanged at 2.8 mm (p = 0.39) in the AP axis, and improved from 2.0 to 1.2 mm in the RL axis (p < 0.001). There

  5. Image reconstruction of dynamic infrared single-pixel imaging system

    Science.gov (United States)

    Tong, Qi; Jiang, Yilin; Wang, Haiyan; Guo, Limin

    2018-03-01

    Single-pixel imaging technique has recently received much attention. Most of the current single-pixel imaging is aimed at relatively static targets or the imaging system is fixed, which is limited by the number of measurements received through the single detector. In this paper, we proposed a novel dynamic compressive imaging method to solve the imaging problem, where exists imaging system motion behavior, for the infrared (IR) rosette scanning system. The relationship between adjacent target images and scene is analyzed under different system movement scenarios. These relationships are used to build dynamic compressive imaging models. Simulation results demonstrate that the proposed method can improve the reconstruction quality of IR image and enhance the contrast between the target and the background in the presence of system movement.

  6. Surface Habitat Systems

    Science.gov (United States)

    Kennedy, Kriss J.

    2009-01-01

    The Surface Habitat Systems (SHS) Focused Investment Group (FIG) is part of the National Aeronautics and Space Administration (NASA) Johnson Space Center (JSC) effort to provide a focused direction and funding to the various projects that are working on human surface habitat designs and technologies for the planetary exploration missions. The overall SHS-FIG effort focuses on directing and guiding those projects that: 1) develop and demonstrate new surface habitat system concepts, innovations, and technologies to support human exploration missions, 2) improve environmental systems that interact with human habitats, 3) handle and emplace human surface habitats, and 4) focus on supporting humans living and working in habitats on planetary surfaces. The activity areas of the SHS FIG described herein are focused on the surface habitat project near-term objectives as described in this document. The SHS-FIG effort focuses on mitigating surface habitat risks (as identified by the Lunar Surface Systems Project Office (LSSPO) Surface Habitat Element Team; and concentrates on developing surface habitat technologies as identified in the FY08 gap analysis. The surface habitat gap assessment will be updated annually as the surface architecture and surface habitat definition continues to mature. These technologies are mapped to the SHS-FIG Strategic Development Roadmap. The Roadmap will bring to light the areas where additional innovative efforts are needed to support the development of habitat concepts and designs and the development of new technologies to support of the LSSPO Habitation Element development plan. Three specific areas of development that address Lunar Architecture Team (LAT)-2 and Constellation Architecture Team (CxAT) Lunar habitat design issues or risks will be focused on by the SHS-FIG. The SHS-FIG will establish four areas of development that will help the projects prepare in their planning for surface habitat systems development. Those development areas are

  7. Implications of Artefacts Reduction in the Planning CT Originating from Implanted Fiducial Markers

    International Nuclear Information System (INIS)

    Kassim, Iskandar; Joosten, Hans; Barnhoorn, Jaco C.; Heijmen, Ben J.M.; Dirkx, Maarten L.P.

    2011-01-01

    The efficacy of metal artefact reduction (MAR) software to suppress artefacts in reconstructed computed tomography (CT) images originating from small metal objects, like tumor markers and surgical clips, was evaluated. In addition, possible implications of using digital reconstructed radiographs (DRRs), based on the MAR CT images, for setup verification were analyzed. A phantom and 15 patients with different tumor sites and implanted markers were imaged with a multislice CT scanner. The raw image data was reconstructed both with the clinically used filtered-backprojection (FBP) and with the MAR software. Using the MAR software, improvements in image quality were often observed in CT slices with markers or clips. Especially when several markers were located near to each other, fewer streak artefacts were observed than with the FBP algorithm. In addition, the shape and size of markers could be identified more accurately, reducing the contoured marker volumes by a factor of 2. For the phantom study, the CT numbers measured near to the markers corresponded more closely to the expected values. However, the MAR images were slightly more smoothed compared with the images reconstructed with FBP. For 8 prostate cancer patients in this study, the interobserver variation in 3D marker definition was similar (<0.4 mm) when using DRRs based on either FBP or MAR CT scans. Automatic marker matches also showed a similar success rate. However, differences in automatic match results up to 1 mm, caused by differences in the marker definition, were observed, which turned out to be (borderline) statistically significant (p = 0.06) for 2 patients. In conclusion, the MAR software might improve image quality by suppressing metal artefacts, probably allowing for a more reliable delineation of structures. When implanted markers or clips are used for setup verification, the accuracy may slightly be improved as well, which is relevant when using very tight clinical target volume (CTV) to

  8. Measuring stone surface area from a radiographic image is accurate and reproducible with the help of an imaging program.

    Science.gov (United States)

    Kurien, Abraham; Ganpule, Arvind; Muthu, V; Sabnis, R B; Desai, Mahesh

    2009-01-01

    The surface area of the stone from a radiographic image is one of the more suitable parameters defining stone bulk. The widely accepted method of measuring stone surface area is to count the number of square millimeters enclosed within a tracing of the stone outline on graph paper. This method is time consuming and cumbersome with potential for human error, especially when multiple measurements are needed. The purpose of this study was to evaluate the accuracy, efficiency, and reproducibility of a commercially available imaging program, Adobe Photoshop 7.0 for the measurement of stone surface area. The instructions to calculate area using the software are simple and easy in a Windows-based format. The accuracy of the imaging software was estimated by measuring surface areas of shapes of known mathematical areas. The efficiency and reproducibility were then evaluated from radiographs of 20 persons with radiopaque upper-tract urinary stones. The surface areas of stone images were measured using both graph paper and imaging software. Measurements were repeated after 10 days to assess the reproducibility of the techniques. The time taken to measure the area by the two methods was also assessed separately. The accuracy of the imaging software was estimated to be 98.7%. The correlation coefficient between the two methods was R(2) = 0.97. The mean percentage variation using the imaging software was 0.68%, while it was 6.36% with the graph paper. The mean time taken to measure using the image analyzer and graph paper was 1.9 +/- 0.8 minutes and 4.5 +/- 1.08 minutes, respectively (P stone surface area from radiographs compared with manual measurements using graph paper.

  9. Improvement of a Vocal Fold Imaging System

    Energy Technology Data Exchange (ETDEWEB)

    Krauter, K. G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-02-01

    Medical professionals can better serve their patients through continual update of their imaging tools. A wide range of pathologies and disease may afflict human vocal cords or, as they’re also known, vocal folds. These diseases can affect human speech hampering the ability of the patient to communicate. Vocal folds must be opened for breathing and the closed to produce speech. Currently methodologies to image markers of potential pathologies are difficult to use and often fail to detect early signs of disease. These current methodologies rely on a strobe light and slower frame rate camera in an attempt to obtain images as the vocal folds travel over the full extent of their motion.

  10. Effects of surface-mapping corrections and synthetic-aperture focusing techniques on ultrasonic imaging

    International Nuclear Information System (INIS)

    Barna, B.A.; Johnson, J.A.

    1981-01-01

    Improvements in ultrasonic imaging that can be obtained using algorithms that map the surface of targets are evaluated. This information is incorporated in the application of synthetic-aperture focusing techniques which also have the potential to improve image resolution. Images obtained using directed-beam (flat) transducers and the focused transducers normally used for synthetic-aperture processing are quantitatively compared by using no processing, synthetic-aperture processing with no corrections for surface variations, and synthetic-aperture processing with surface mapping. The unprocessed images have relatively poor lateral resolutions because echoes from two adjacent reflectors show interference effects which prevent their identification even if the spacing is larger than the single-hole resolution. The synthetic-aperture-processed images show at least a twofold improvement in lateral resolution and greatly reduced interference effects in multiple-hole images compared to directed-beam images. Perhaps more importantly, in images of test blocks with substantial surface variations portions of the image are displaced from their actual positions by several wavelengths. To correct for this effect an algorithm has been developed for calculating the surface variations. The corrected images produced using this algorithm are accurate within the experimental error. In addition, the same algorithm, when applied to the directed-beam data, produced images that are not only accurately positioned, but that also have a resolution comparable to conventional synthetic-aperture-processed images obtained from focused-transducer data. This suggests that using synthetic-aperture processing on the type of data normally collected during directed-beam ultrasonic inspections would eliminate the need to rescan for synthetic-aperture enhancement

  11. Surface analysis of lipids by mass spectrometry: more than just imaging.

    Science.gov (United States)

    Ellis, Shane R; Brown, Simon H; In Het Panhuis, Marc; Blanksby, Stephen J; Mitchell, Todd W

    2013-10-01

    Mass spectrometry is now an indispensable tool for lipid analysis and is arguably the driving force in the renaissance of lipid research. In its various forms, mass spectrometry is uniquely capable of resolving the extensive compositional and structural diversity of lipids in biological systems. Furthermore, it provides the ability to accurately quantify molecular-level changes in lipid populations associated with changes in metabolism and environment; bringing lipid science to the "omics" age. The recent explosion of mass spectrometry-based surface analysis techniques is fuelling further expansion of the lipidomics field. This is evidenced by the numerous papers published on the subject of mass spectrometric imaging of lipids in recent years. While imaging mass spectrometry provides new and exciting possibilities, it is but one of the many opportunities direct surface analysis offers the lipid researcher. In this review we describe the current state-of-the-art in the direct surface analysis of lipids with a focus on tissue sections, intact cells and thin-layer chromatography substrates. The suitability of these different approaches towards analysis of the major lipid classes along with their current and potential applications in the field of lipid analysis are evaluated. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Computerized method for estimation of the location of a lung tumor on EPID cine images without implanted markers in stereotactic body radiotherapy

    International Nuclear Information System (INIS)

    Arimura, H; Toyofuku, F; Higashida, Y; Onizuka, Y; Terashima, H; Egashira, Y; Shioyama, Y; Nomoto, S; Honda, H; Nakamura, K; Yoshidome, S; Anai, S

    2009-01-01

    The purpose of this study was to develop a computerized method for estimation of the location of a lung tumor in cine images on an electronic portal imaging device (EPID) without implanted markers during stereotactic body radiotherapy (SBRT). Each tumor region was segmented in the first EPID cine image, i.e., reference portal image, based on a multiple-gray level thresholding technique and a region growing technique, and then the image including the tumor region was cropped as a 'tumor template' image. The tumor location was determined as the position in which the tumor template image took the maximum cross-correlation value within each consecutive portal image, which was acquired in cine mode on the EPID in treatment. EPID images with 512 x 384 pixels (pixel size: 0.56 mm) were acquired at a sampling rate of 0.5 frame s -1 by using energies of 4, 6 or 10 MV on linear accelerators. We applied our proposed method to EPID cine images (226 frames) of 12 clinical cases (ages: 51-83, mean: 72) with a non-small cell lung cancer. As a result, the average location error between tumor points obtained by our method and the manual method was 1.47 ± 0.60 mm. This preliminary study suggests that our method based on the tumor template matching technique might be feasible for tracking the location of a lung tumor without implanted markers in SBRT.

  13. Two EST-derived marker systems for cultivar identification in tree peony.

    Science.gov (United States)

    Zhang, J J; Shu, Q Y; Liu, Z A; Ren, H X; Wang, L S; De Keyser, E

    2012-02-01

    Tree peony (Paeonia suffruticosa Andrews), a woody deciduous shrub, belongs to the section Moutan DC. in the genus of Paeonia of the Paeoniaceae family. To increase the efficiency of breeding, two EST-derived marker systems were developed based on a tree peony expressed sequence tag (EST) database. Using target region amplification polymorphism (TRAP), 19 of 39 primer pairs showed good amplification for 56 accessions with amplicons ranging from 120 to 3,000 bp long, among which 99.3% were polymorphic. In contrast, 7 of 21 primer pairs demonstrated adequate amplification with clear bands for simple sequence repeats (SSRs) developed from ESTs, and a total of 33 alleles were found in 56 accessions. The similarity matrices generated by TRAP and EST-SSR markers were compared, and the Mantel test (r = 0.57778, P = 0.0020) showed a moderate correlation between the two types of molecular markers. TRAP markers were suitable for DNA fingerprinting and EST-SSR markers were more appropriate for discriminating synonyms (the same cultivars with different names due to limited information exchanged among different geographic areas). The two sets of EST-derived markers will be used further for genetic linkage map construction and quantitative trait locus detection in tree peony.

  14. Torso geometry reconstruction and body surface electrode localization using three-dimensional photography.

    Science.gov (United States)

    Perez-Alday, Erick A; Thomas, Jason A; Kabir, Muammar; Sedaghat, Golriz; Rogovoy, Nichole; van Dam, Eelco; van Dam, Peter; Woodward, William; Fuss, Cristina; Ferencik, Maros; Tereshchenko, Larisa G

    We conducted a prospective clinical study (n=14; 29% female) to assess the accuracy of a three-dimensional (3D) photography-based method of torso geometry reconstruction and body surface electrodes localization. The position of 74 body surface electrocardiographic (ECG) electrodes (diameter 5mm) was defined by two methods: 3D photography, and CT (marker diameter 2mm) or MRI (marker size 10×20mm) imaging. Bland-Altman analysis showed good agreement in X (bias -2.5 [95% limits of agreement (LoA) -19.5 to 14.3] mm), Y (bias -0.1 [95% LoA -14.1 to 13.9] mm), and Z coordinates (bias -0.8 [95% LoA -15.6 to 14.2] mm), as defined by the CT/MRI imaging, and 3D photography. The average Hausdorff distance between the two torso geometry reconstructions was 11.17±3.05mm. Thus, accurate torso geometry reconstruction using 3D photography is feasible. Body surface ECG electrodes coordinates as defined by the CT/MRI imaging, and 3D photography, are in good agreement. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Imaging the Surfaces of Stars from Space

    Science.gov (United States)

    Carpenter, Kenneth; Rau, Gioia

    2018-04-01

    Imaging of Stellar Surfacess has been dominated to-date by ground-based observations, but space-based facilities offer tremendous potential for extending the wavelength coverage and ultimately the resolution of such efforts. We review the imaging accomplished so far from space and then talk about exciting future prospects. The earliest attempts from space indirectly produced surface maps via the Doppler Imaging Technique, using UV spectra obtained with the International Ultraviolet Explorer (IUE). Later, the first direct UV images were obtained with the Hubble Space Telescope (HST), of Mira and Betelgeuse, using the Faint Object Camera (FOC). We will show this work and then investigate prospects for IR imaging with the James Webb Space Telescope (JWST). The real potential of space-based Imaging of Stellar Surfacess, however, lies in the future, when large-baseline Fizeau interferometers, such as the UV-optical Stellar Imager (SI) Vision Mission, with a 30-element array and 500m max baseline, are flown. We describe SI and its science goals, which include 0.1 milli-arcsec spectral Imaging of Stellar Surfacess and the probing of internal structure and flows via asteroseismology.

  16. The correlation between internal and external markers for abdominal tumors: Implications for respiratory gating

    International Nuclear Information System (INIS)

    Gierga, David P.; Brewer, Johanna; Sharp, Gregory C.; Betke, Margrit; Willett, Christopher G.; Chen, George T.Y.

    2005-01-01

    Purpose: The correlation of the respiratory motion of external patient markers and abdominal tumors was examined. Data of this type are important for image-guided therapy techniques, such as respiratory gating, that monitor the movement of external fiducials. Methods and Materials: Fluoroscopy sessions for 4 patients with internal, radiopaque tumor fiducial clips were analyzed by computer vision techniques. The motion of the internal clips and the external markers placed on the patient's abdominal skin surface were quantified and correlated. Results: In general, the motion of the tumor and external markers were well correlated. The maximum amount of peak-to-peak craniocaudal tumor motion was 2.5 cm. The ratio of tumor motion to external-marker motion ranged from 0.85 to 7.1. The variation in tumor position for a given external-marker position ranged from 2 to 9 mm. The period of the breathing cycle ranged from 2.7 to 4.5 seconds, and the frequency patterns for both the tumor and the external markers were similar. Conclusions: Although tumor motion generally correlated well with external fiducial marker motion, relatively large underlying tumor motion can occur compared with external-marker motion and variations in the tumor position for a given marker position. Treatment margins should be determined on the basis of a detailed understanding of tumor motion, as opposed to relying only on external-marker information

  17. Metal surface corrosion grade estimation from single image

    Science.gov (United States)

    Chen, Yijun; Qi, Lin; Sun, Huyuan; Fan, Hao; Dong, Junyu

    2018-04-01

    Metal corrosion can cause many problems, how to quickly and effectively assess the grade of metal corrosion and timely remediation is a very important issue. Typically, this is done by trained surveyors at great cost. Assisting them in the inspection process by computer vision and artificial intelligence would decrease the inspection cost. In this paper, we propose a dataset of metal surface correction used for computer vision detection and present a comparison between standard computer vision techniques by using OpenCV and deep learning method for automatic metal surface corrosion grade estimation from single image on this dataset. The test has been performed by classifying images and calculating the accuracy for the two different approaches.

  18. An imaging system for quantitive surface temperature mapping using two-color thermographic phosphors

    Science.gov (United States)

    Buck, Gregory M.

    1988-01-01

    A technique for obtaining detailed quantitative temperature distributions on test models in hypersonic wind tunnels is presented. This technique is based on the ratio of blue to green (450, 520 nm) emission from an UV (365 nm) excited phosphor coating. Separately filtered images are recorded from a three-tube color camera, utilizing off-the-shelf front-end video optics to discriminate wavelengths. Two demonstration studies in a 31-inch Mach 10 tunnel are discussed. One study presents the windward surface temperature-time history for a transatmospheric vehicle, and the other illustrates nosetip heating on a spherically blunted slender cone.

  19. Monitoring Cu nodule formation using Ni marker layers

    Energy Technology Data Exchange (ETDEWEB)

    Lafouresse, M.C., E-mail: mlafouresse@gmail.co [Department of Civil and Earth Resources Engineering, Kyoto University, Katsura, Kyoto 615-8540 (Japan); Fukunaka, Y. [Institute for Nanoscience and Nanotechnology, Waseda University, Shinjuku Ku, Tokyo 169-8555 (Japan); ISS Science Project Office, JAXA, Tsukuba-shi, Ibaraki 305-8505 (Japan); Matsuoka, T. [Department of Civil and Earth Resources Engineering, Kyoto University, Katsura, Kyoto 615-8540 (Japan); Schwarzacher, W. [H. H. Wills Physics Laboratory, Tyndall Avenue, Bristol BS8 1TL (United Kingdom)

    2011-04-30

    Highlights: {yields} Ni marker layers to monitor electrodeposited Cu nodule morphological evolution. {yields} The edges of the nodules trace out a straight line. {yields} Difference in growth between spheres and hemispheres. {yields} Nodule on nodule growth at high overpotential. {yields} No dramatic effect of the diffusion layer thickness on the film morphology. - Abstract: We have used Ni marker layers to study the evolution of the characteristic spheroidal nodule morphology in electrodeposited Cu films. Ultrathin Ni layers were electrodeposited in-between Cu layers, and cross sections prepared by electrochemical polishing. During growth of a typical spheroidal feature, the edge (i.e. where there is a discontinuity in the surface slope) traces out a straight line in the cross-sectional image. At high overpotential, the cross-sections show nodule-on-nodule growth, giving rise to the well known cauliflower morphology. Rotating disk electrode studies reveal that, surprisingly, the absolute diffusion layer thickness does not appear to play a major role in the development of spheres.

  20. Monitoring Cu nodule formation using Ni marker layers

    International Nuclear Information System (INIS)

    Lafouresse, M.C.; Fukunaka, Y.; Matsuoka, T.; Schwarzacher, W.

    2011-01-01

    Highlights: → Ni marker layers to monitor electrodeposited Cu nodule morphological evolution. → The edges of the nodules trace out a straight line. → Difference in growth between spheres and hemispheres. → Nodule on nodule growth at high overpotential. → No dramatic effect of the diffusion layer thickness on the film morphology. - Abstract: We have used Ni marker layers to study the evolution of the characteristic spheroidal nodule morphology in electrodeposited Cu films. Ultrathin Ni layers were electrodeposited in-between Cu layers, and cross sections prepared by electrochemical polishing. During growth of a typical spheroidal feature, the edge (i.e. where there is a discontinuity in the surface slope) traces out a straight line in the cross-sectional image. At high overpotential, the cross-sections show nodule-on-nodule growth, giving rise to the well known cauliflower morphology. Rotating disk electrode studies reveal that, surprisingly, the absolute diffusion layer thickness does not appear to play a major role in the development of spheres.

  1. Improving Image Matching by Reducing Surface Reflections Using Polarising Filter Techniques

    Science.gov (United States)

    Conen, N.; Hastedt, H.; Kahmen, O.; Luhmann, T.

    2018-05-01

    In dense stereo matching applications surface reflections may lead to incorrect measurements and blunders in the resulting point cloud. To overcome the problem of disturbing reflexions polarising filters can be mounted on the camera lens and light source. Reflections in the images can be suppressed by crossing the polarising direction of the filters leading to homogeneous illuminated images and better matching results. However, the filter may influence the camera's orientation parameters as well as the measuring accuracy. To quantify these effects, a calibration and an accuracy analysis is conducted within a spatial test arrangement according to the German guideline VDI/VDE 2634.1 (2002) using a DSLR with and without polarising filter. In a second test, the interior orientation is analysed in more detail. The results do not show significant changes of the measuring accuracy in object space and only very small changes of the interior orientation (Δc ≤ 4 μm) with the polarising filter in use. Since in medical applications many tiny reflections are present and impede robust surface measurements, a prototypic trinocular endoscope is equipped with polarising technique. The interior and relative orientation is determined and analysed. The advantage of the polarising technique for medical image matching is shown in an experiment with a moistened pig kidney. The accuracy and completeness of the resulting point cloud can be improved clearly when using polarising filters. Furthermore, an accuracy analysis using a laser triangulation system is performed and the special reflection properties of metallic surfaces are presented.

  2. IMPROVING IMAGE MATCHING BY REDUCING SURFACE REFLECTIONS USING POLARISING FILTER TECHNIQUES

    Directory of Open Access Journals (Sweden)

    N. Conen

    2018-05-01

    Full Text Available In dense stereo matching applications surface reflections may lead to incorrect measurements and blunders in the resulting point cloud. To overcome the problem of disturbing reflexions polarising filters can be mounted on the camera lens and light source. Reflections in the images can be suppressed by crossing the polarising direction of the filters leading to homogeneous illuminated images and better matching results. However, the filter may influence the camera’s orientation parameters as well as the measuring accuracy. To quantify these effects, a calibration and an accuracy analysis is conducted within a spatial test arrangement according to the German guideline VDI/VDE 2634.1 (2002 using a DSLR with and without polarising filter. In a second test, the interior orientation is analysed in more detail. The results do not show significant changes of the measuring accuracy in object space and only very small changes of the interior orientation (Δc ≤ 4 μm with the polarising filter in use. Since in medical applications many tiny reflections are present and impede robust surface measurements, a prototypic trinocular endoscope is equipped with polarising technique. The interior and relative orientation is determined and analysed. The advantage of the polarising technique for medical image matching is shown in an experiment with a moistened pig kidney. The accuracy and completeness of the resulting point cloud can be improved clearly when using polarising filters. Furthermore, an accuracy analysis using a laser triangulation system is performed and the special reflection properties of metallic surfaces are presented.

  3. Concave omnidirectional imaging device for cylindrical object based on catadioptric panoramic imaging

    Science.gov (United States)

    Wu, Xiaojun; Wu, Yumei; Wen, Peizhi

    2018-03-01

    To obtain information on the outer surface of a cylinder object, we propose a catadioptric panoramic imaging system based on the principle of uniform spatial resolution for vertical scenes. First, the influence of the projection-equation coefficients on the spatial resolution and astigmatism of the panoramic system are discussed, respectively. Through parameter optimization, we obtain the appropriate coefficients for the projection equation, and so the imaging quality of the entire imaging system can reach an optimum value. Finally, the system projection equation is calibrated, and an undistorted rectangular panoramic image is obtained using the cylindrical-surface projection expansion method. The proposed 360-deg panoramic-imaging device overcomes the shortcomings of existing surface panoramic-imaging methods, and it has the advantages of low cost, simple structure, high imaging quality, and small distortion, etc. The experimental results show the effectiveness of the proposed method.

  4. Remote Monitoring of Near-Surface Soil Moisture Dynamics In Unstable Slopes Using a Low-Power Autonomous Resistivity Imaging System

    Science.gov (United States)

    Chambers, J. E.; Meldrum, P.; Gunn, D.; Wilkinson, P. B.; Uhlemann, S.; Swift, R. T.; Kuras, O.; Inauen, C.; Hutchinson, D.; Butler, S.

    2016-12-01

    ERT monitoring has been demonstrated in numerous studies as an effective means of imaging near surface processes for applications as diverse as permafrost studies and contaminated land assessment. A limiting factor in applying time-lapse ERT for long-term studies in remote locations has been the availability of cost-effective ERT measurement systems designed specifically for monitoring applications. Typically, monitoring is undertaken using repeated manual data collection, or by building conventional survey instruments into a monitoring setup. The latter often requires high power and is therefore difficult to operate remotely without access to mains electricity. We describe the development of a low-power resistivity imaging system designed specifically for remote monitoring, taking advantage of, e.g., solar power and data telemetry. Here, we present the results of two field deployments. The system has been installed on an active railway cutting to provide insights into the effect of vegetation on the moisture dynamics in unstable infrastructure slopes and to gather subsurface information for pro-active remediation measures. The system, comprising 255 electrodes, acquires 4596 reciprocal measurement pairs twice daily during standard operation. In case of severe weather events, the measurement schedule is reactively changed, to gather high temporal resolution data to image rainfall infiltration processes. The system has also been installed along a leaking and marginally stable canal embankment; a less favourable location for remote monitoring, with limited solar power and poor mobile reception. Nevertheless, the acquired data indicated the effectiveness of remedial actions on the canal. The ERT results showed that one leak was caused by the canal and fixed during remediation, while two other "leaks" were shown to be effects of groundwater dynamics. The availability of cost-effective, low-power ERT monitoring instrumentation, combined with an automated workflow of

  5. Development of ballistics identification—from image comparison to topography measurement in surface metrology

    International Nuclear Information System (INIS)

    Song, J; Chu, W; Vorburger, T V; Thompson, R; Renegar, T B; Zheng, A; Yen, J; Silver, R; Ols, M

    2012-01-01

    Fired bullets and ejected cartridge cases have unique ballistics signatures left by the firearm. By analyzing the ballistics signatures, forensic examiners can trace these bullets and cartridge cases to the firearm used in a crime scene. Current automated ballistics identification systems are primarily based on image comparisons using optical microscopy. The correlation accuracy depends on image quality which is largely affected by lighting conditions. Because ballistics signatures are geometrical micro-topographies by nature, direct measurement and correlation of the surface topography is being investigated for ballistics identification. A Two-dimensional and Three-dimensional Topography Measurement and Correlation System was developed at the National Institute of Standards and Technology for certification of Standard Reference Material 2460/2461 bullets and cartridge cases. Based on this system, a prototype system for bullet signature measurement and correlation has been developed for bullet signature identifications, and has demonstrated superior correlation results. (paper)

  6. IMPACT: Imaging and Molecular Markers for Patients with Lung Cancer: Approaches with Molecular Targets, Complementary/Innovative Treatments, and Therapeutic Modalities

    Science.gov (United States)

    2016-04-01

    imaging, MRI and CT scan in vivo imaging, and/or heat deposition for NIR photo-therapy. The identification of vascular markers targeted by...studies, as a prelude to potential clinical trials, is to secure a large source of the drug from our pharmaceutical counterparts. Therefore, from the...beginning of this project, we tried to identify agents that target FGF receptor signaling and are under development in pharmaceutical companies. We had

  7. Bone surface enhancement in ultrasound images using a new Doppler-based acquisition/processing method

    Science.gov (United States)

    Yang, Xu; Tang, Songyuan; Tasciotti, Ennio; Righetti, Raffaella

    2018-01-01

    Ultrasound (US) imaging has long been considered as a potential aid in orthopedic surgeries. US technologies are safe, portable and do not use radiations. This would make them a desirable tool for real-time assessment of fractures and to monitor fracture healing. However, image quality of US imaging methods in bone applications is limited by speckle, attenuation, shadow, multiple reflections and other imaging artifacts. While bone surfaces typically appear in US images as somewhat ‘brighter’ than soft tissue, they are often not easily distinguishable from the surrounding tissue. Therefore, US imaging methods aimed at segmenting bone surfaces need enhancement in image contrast prior to segmentation to improve the quality of the detected bone surface. In this paper, we present a novel acquisition/processing technique for bone surface enhancement in US images. Inspired by elastography and Doppler imaging methods, this technique takes advantage of the difference between the mechanical and acoustic properties of bones and those of soft tissues to make the bone surface more easily distinguishable in US images. The objective of this technique is to facilitate US-based bone segmentation methods and improve the accuracy of their outcomes. The newly proposed technique is tested both in in vitro and in vivo experiments. The results of these preliminary experiments suggest that the use of the proposed technique has the potential to significantly enhance the detectability of bone surfaces in noisy ultrasound images.

  8. Bone surface enhancement in ultrasound images using a new Doppler-based acquisition/processing method.

    Science.gov (United States)

    Yang, Xu; Tang, Songyuan; Tasciotti, Ennio; Righetti, Raffaella

    2018-01-17

    Ultrasound (US) imaging has long been considered as a potential aid in orthopedic surgeries. US technologies are safe, portable and do not use radiations. This would make them a desirable tool for real-time assessment of fractures and to monitor fracture healing. However, image quality of US imaging methods in bone applications is limited by speckle, attenuation, shadow, multiple reflections and other imaging artifacts. While bone surfaces typically appear in US images as somewhat 'brighter' than soft tissue, they are often not easily distinguishable from the surrounding tissue. Therefore, US imaging methods aimed at segmenting bone surfaces need enhancement in image contrast prior to segmentation to improve the quality of the detected bone surface. In this paper, we present a novel acquisition/processing technique for bone surface enhancement in US images. Inspired by elastography and Doppler imaging methods, this technique takes advantage of the difference between the mechanical and acoustic properties of bones and those of soft tissues to make the bone surface more easily distinguishable in US images. The objective of this technique is to facilitate US-based bone segmentation methods and improve the accuracy of their outcomes. The newly proposed technique is tested both in in vitro and in vivo experiments. The results of these preliminary experiments suggest that the use of the proposed technique has the potential to significantly enhance the detectability of bone surfaces in noisy ultrasound images.

  9. Evaluation of different magnetic resonance imaging contrast materials to be used as dummy markers in image-guided brachytherapy for gynecologic malignancies*

    Science.gov (United States)

    Sales, Camila Pessoa; Carvalho, Heloisa de Andrade; Taverna, Khallil Chaim; Pastorello, Bruno Fraccini; Rubo, Rodrigo Augusto; Borgonovi, Arthur Felipe; Stuart, Silvia Radwanski; Rodrigues, Laura Natal

    2016-01-01

    Objective To identify a contrast material that could be used as a dummy marker for magnetic resonance imaging. Materials and Methods Magnetic resonance images were acquired with six different catheter-filling materials-water, glucose 50%, saline, olive oil, glycerin, and copper sulfate (CuSO4) water solution (2.08 g/L)-inserted into compatible computed tomography/magnetic resonance imaging ring applicators placed in a phantom made of gelatin and CuSO4. The best contrast media were tested in four patients with the applicators in place. Results In T2-weighted sequences, the best contrast was achieved with the CuSO4-filled catheters, followed by saline- and glycerin-filled catheters, which presented poor visualization. In addition (also in T2-weighted sequences), CuSO4 presented better contrast when tested in the phantom than when tested in the patients, in which it provided some contrast but with poor identification of the first dwell position, mainly in the ring. Conclusion We found CuSO4 to be the best solution for visualization of the applicator channels, mainly in T2-weighted images in vitro, although the materials tested presented low signal intensity in the images obtained in vivo, as well as poor precision in determining the first dwell position. PMID:27403016

  10. Evaluation of different magnetic resonance imaging contrast materials to be used as dummy markers in image-guided brachytherapy for gynecologic malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Sales, Camila Pessoa; Carvalho, Heloisa de Andrade; Rubo, Rodrigo Augusto; Stuart, Silvia Radwanski; Rodrigues, Laura Natal, E-mail: camyps@gmail.com [Universidade de Sao Paulo (InRad/HC/FM/USP), Sao Paulo, SP (Brazil). Faculdade de Medicina. Instituto de Radiologia; Taverna, Khallil Chaim; Pastorello, Bruno Fraccini [Universidade de Sao Paulo (FM/USP), Sao Paulo, SP (Brazil). Departamento de Radiologia e Oncologia. Lab. de Ressonancia Magnetica em Neurorradiologia; Borgonovi, Arthur Felipe [Royal Philips Electronics, Eindhoven (Netherlands)

    2016-05-15

    Objective: to identify a contrast material that could be used as a dummy marker for magnetic resonance imaging. Materials and methods: magnetic resonance images were acquired with six different catheter-filling materials - water, glucose 50%, saline, olive oil, glycerin, and copper sulfate (CuSO{sub 4}) water solution (2.08 g/L) - inserted into compatible computed tomography/magnetic resonance imaging ring applicators placed in a phantom made of gelatin and CuSO{sub 4}. The best contrast media were tested in four patients with the applicators in place. Results: in T2-weighted sequences, the best contrast was achieved with the CuSO{sub 4}-filled catheters, followed by saline- and glycerin-filled catheters, which presented poor visualization. In addition (also in T2-weighted sequences), CuSO{sub 4} presented better contrast when tested in the phantom than when tested in the patients, in which it provided some contrast but with poor identification of the first dwell position, mainly in the ring. Conclusion: we found CuSO{sub 4} to be the best solution for visualization of the applicator channels, mainly in T2-weighted images in vitro, although the materials tested presented low signal intensity in the images obtained in vivo, as well as poor precision in determining the first dwell position. (author)

  11. Quality transitivity and traceability system of herbal medicine products based on quality markers.

    Science.gov (United States)

    Liu, Changxiao; Guo, De-An; Liu, Liang

    2018-05-15

    Due to a variety of factors to affect the herb quality, the existing quality management model is unable to evaluate the process control. The development of the concept of "quality marker" (Q-marker) lays basis for establishing an independent process quality control system for herbal products. To ensure the highest degree of safety, effectiveness and quality process control of herbal products, it is aimed to establish a quality transitivity and traceability system of quality and process control from raw materials to finished herbal products. Based on the key issues and challenges of quality assessment, the current status of quality and process controls from raw materials to herbal medicinal products listed in Pharmacopoeia were analyzed and the research models including discovery and identification of Q-markers, analysis and quality management of risk evaluation were designed. Authors introduced a few new technologies and methodologies, such as DNA barcoding, chromatographic technologies, fingerprint analysis, chemical markers, bio-responses, risk management and solution for quality process control. The quality and process control models for herbal medicinal products were proposed and the transitivity and traceability system from raw materials to the finished products was constructed to improve the herbal quality from the entire supply and production chain. The transitivity and traceability system has been established based on quality markers, especially on how to control the production process under Good Engineering Practices, as well as to implement the risk management for quality and process control in herbal medicine production. Copyright © 2018 Elsevier GmbH. All rights reserved.

  12. Imaging systems in nuclear medicine and image evaluation

    International Nuclear Information System (INIS)

    Beck, R.; Charleston, D.; Metz, C.

    1980-01-01

    This project deals with imaging systems in nuclear medicine and image evaluation and is presented as four subprojects. The goal of the first subproject is to improve diagnositc image quality by development of a general computer code for optimizing collimator design. The second subproject deals with a secondary emission and fluorescence technique for thyroid scanning while the third subproject emphasizes the need for more sophisticated image processing systems such as coherent optical spatial filtering systems and digital image processing. The fourth subproject presents a new approach for processing image data by taking into account the energy of each detected gamma-ray photon

  13. Comparison between skin-mounted fiducials and bone-implanted fiducials for image-guided neurosurgery

    Science.gov (United States)

    Rost, Jennifer; Harris, Steven S.; Stefansic, James D.; Sillay, Karl; Galloway, Robert L., Jr.

    2004-05-01

    Point-based registration for image-guided neurosurgery has become the industry standard. While the use of intrinsic points is appealing because of its retrospective nature, affixing extrinsic objects to the head prior to scanning has been demonstrated to provide much more accurate registrations. Points of reference between image space and physical space are called fiducials. The extrinsic objects which generate those points are fiducial markers. The markers can be broken down into two classifications: skin-mounted and bone-implanted. Each has distinct advantages and disadvantages. Skin-mounted fiducials require simply sticking them on the patient in locations suggested by the manufacturer, however, they can move with tractions placed on the skin, fall off and perhaps the most dangerous problem, they can be replaced by the patient. Bone implanted markers being rigidly affixed to the skull do not present such problems. However, a minor surgical intervention (analogous to dental work) must be performed to implant the markers prior to surgery. Therefore marker type and use has become a decision point for image-guided surgery. We have performed a series of experiments in an attempt to better quantify aspects of the two types of markers so that better informed decisions can be made. We have created a phantom composed of a full-size plastic skull [Wards Scientific Supply] with a 500 ml bag of saline placed in the brain cavity. The skull was then sealed. A skin mimicking material, DragonSkinTM [SmoothOn Company] was painted onto the surface and allowed to dry. Skin mounted fiducials [Medtronic-SNT] and bone-implanted markers [Z-Kat]were placed on the phantom. In addition, three additional bone-implanted markers were placed (two on the base of the skull and one in the eye socket for use as targets). The markers were imaged in CT and 4 MRI sequences (T1-weighted, T2 weighted, SPGR, and a functional series.) The markers were also located in physical space using an Optotrak

  14. Method comparison of ultrasound and kilovoltage x-ray fiducial marker imaging for prostate radiotherapy targeting

    Science.gov (United States)

    Fuller, Clifton David; Thomas, Charles R., Jr.; Schwartz, Scott; Golden, Nanalei; Ting, Joe; Wong, Adrian; Erdogmus, Deniz; Scarbrough, Todd J.

    2006-10-01

    Several measurement techniques have been developed to address the capability for target volume reduction via target localization in image-guided radiotherapy; among these have been ultrasound (US) and fiducial marker (FM) software-assisted localization. In order to assess interchangeability between methods, US and FM localization were compared using established techniques for determination of agreement between measurement methods when a 'gold-standard' comparator does not exist, after performing both techniques daily on a sequential series of patients. At least 3 days prior to CT simulation, four gold seeds were placed within the prostate. FM software-assisted localization utilized the ExacTrac X-Ray 6D (BrainLab AG, Germany) kVp x-ray image acquisition system to determine prostate position; US prostate targeting was performed on each patient using the SonArray (Varian, Palo Alto, CA). Patients were aligned daily using laser alignment of skin marks. Directional shifts were then calculated by each respective system in the X, Y and Z dimensions before each daily treatment fraction, previous to any treatment or couch adjustment, as well as a composite vector of displacement. Directional shift agreement in each axis was compared using Altman-Bland limits of agreement, Lin's concordance coefficient with Partik's grading schema, and Deming orthogonal bias-weighted correlation methodology. 1019 software-assisted shifts were suggested by US and FM in 39 patients. The 95% limits of agreement in X, Y and Z axes were ±9.4 mm, ±11.3 mm and ±13.4, respectively. Three-dimensionally, measurements agreed within 13.4 mm in 95% of all paired measures. In all axes, concordance was graded as 'poor' or 'unacceptable'. Deming regression detected proportional bias in both directional axes and three-dimensional vectors. Our data suggest substantial differences between US and FM image-guided measures and subsequent suggested directional shifts. Analysis reveals that the vast majority of

  15. Differential expression of growth factor receptors and membrane-bound tumor markers for imaging in male and female breast cancer.

    Directory of Open Access Journals (Sweden)

    Jeroen F Vermeulen

    Full Text Available INTRODUCTION: Male breast cancer accounts for 0.5-1% of all breast cancers and is generally diagnosed at higher stage than female breast cancers and therefore might benefit from earlier detection and targeted therapy. Except for HER2 and EGFR, little is known about expression of growth factor receptors in male breast cancer. We therefore investigated expression profiles of growth factor receptors and membrane-bound tumor markers in male breast cancer and gynecomastia, in comparison with female breast cancer. METHODS: Tissue microarrays containing 133 male breast cancer and 32 gynecomastia cases were stained by immunohistochemistry for a panel of membrane-bound targets and compared with data on 266 female breast cancers. RESULTS: Growth factor receptors were variably expressed in 4.5% (MET up to 38.5% (IGF1-R of male breast cancers. Compared to female breast cancer, IGF1-R and carbonic anhydrase 12 (CAXII were more frequently and CD44v6, MET and FGFR2 less frequently expressed in male breast cancer. Expression of EGFR, HER2, CAIX, and GLUT1 was not significantly different between male and female breast cancer. Further, 48.1% of male breast cancers expressed at least one and 18.0% expressed multiple growth factor receptors. Since individual membrane receptors are expressed in only half of male breast cancers, a panel of membrane markers will be required for molecular imaging strategies to reach sensitivity. A potential panel of markers for molecular imaging, consisting of EGFR, IGF1-R, FGFR2, CD44v6, CAXII, GLUT1, and CD44v6 was positive in 77% of male breast cancers, comparable to female breast cancers. CONCLUSIONS: Expression patterns of growth factor receptors and hypoxia membrane proteins in male breast cancer are different from female breast cancer. For molecular imaging strategies, a putative panel consisting of markers for EGFR, IGF1-R, FGFR2, GLUT1, CAXII, CD44v6 was positive in 77% of cases and might be considered for development of

  16. Preliminary Study on Earthquake Surface Rupture Extraction from Uav Images

    Science.gov (United States)

    Yuan, X.; Wang, X.; Ding, X.; Wu, X.; Dou, A.; Wang, S.

    2018-04-01

    Because of the advantages of low-cost, lightweight and photography under the cloud, UAVs have been widely used in the field of seismic geomorphology research in recent years. Earthquake surface rupture is a typical seismic tectonic geomorphology that reflects the dynamic and kinematic characteristics of crustal movement. The quick identification of earthquake surface rupture is of great significance for understanding the mechanism of earthquake occurrence, disasters distribution and scale. Using integrated differential UAV platform, series images were acquired with accuracy POS around the former urban area (Qushan town) of Beichuan County as the area stricken seriously by the 2008 Wenchuan Ms8.0 earthquake. Based on the multi-view 3D reconstruction technique, the high resolution DSM and DOM are obtained from differential UAV images. Through the shade-relief map and aspect map derived from DSM, the earthquake surface rupture is extracted and analyzed. The results show that the surface rupture can still be identified by using the UAV images although the time of earthquake elapse is longer, whose middle segment is characterized by vertical movement caused by compression deformation from fault planes.

  17. Prospective Isolation of Murine and Human Bone Marrow Mesenchymal Stem Cells Based on Surface Markers

    Directory of Open Access Journals (Sweden)

    Yo Mabuchi

    2013-01-01

    Full Text Available Mesenchymal stem cells (MSCs are currently defined as multipotent stromal cells that undergo sustained in vitro growth and can give rise to cells of multiple mesenchymal lineages, such as adipocytes, chondrocytes, and osteoblasts. The regenerative and immunosuppressive properties of MSCs have led to numerous clinical trials exploring their utility for the treatment of a variety of diseases (e.g., acute graft-versus-host disease, Crohn’s disease, multiple sclerosis, osteoarthritis, and cardiovascular diseases including heart failure and myocardial infarction. On the other hand, conventionally cultured MSCs reflect heterogeneous populations that often contain contaminating cells due to the significant variability in isolation methods and the lack of specific MSC markers. This review article focuses on recent developments in the MSC research field, with a special emphasis on the identification of novel surface markers for the in vivo localization and prospective isolation of murine and human MSCs. Furthermore, we discuss the physiological importance of MSC subtypes in vivo with specific reference to data supporting their contribution to HSC niche homeostasis. The isolation of MSCs using selective markers (combination of PDGFRα and Sca-1 is crucial to address the many unanswered questions pertaining to these cells and has the potential to enhance their therapeutic potential enormously.

  18. Photoacoustic imaging of hidden dental caries by using a fiber-based probing system

    Science.gov (United States)

    Koyama, Takuya; Kakino, Satoko; Matsuura, Yuji

    2017-04-01

    Photoacoustic method to detect hidden dental caries is proposed. It was found that high frequency ultrasonic waves are generated from hidden carious part when radiating laser light to occlusal surface of model tooth. By making a map of intensity of these high frequency components, photoacoustic images of hidden caries were successfully obtained. A photoacoustic imaging system using a bundle of hollow optical fiber was fabricated for using clinical application, and clear photoacoustic image of hidden caries was also obtained by this system.

  19. Development of an image processing system at the Technology Applications Center, UNM: Landsat image processing in mineral exploration and related activities. Final report

    International Nuclear Information System (INIS)

    Budge, T.K.

    1980-09-01

    This project was a demonstration of the capabilities of Landsat satellite image processing applied to the monitoring of mining activity in New Mexico. Study areas included the Navajo coal surface mine, the Jackpile uranium surface mine, and the potash mining district near Carlsbad, New Mexico. Computer classifications of a number of land use categories in these mines were presented and discussed. A literature review of a number of case studies concerning the use of Landsat image processing in mineral exploration and related activities was prepared. Included in this review is a discussion of the Landsat satellite system and the basics of computer image processing. Topics such as destriping, contrast stretches, atmospheric corrections, ratioing, and classification techniques are addressed. Summaries of the STANSORT II and ELAS software packages and the Technology Application Center's Digital Image Processing System (TDIPS) are presented

  20. Quantitative sub-surface and non-contact imaging using scanning microwave microscopy

    International Nuclear Information System (INIS)

    Gramse, Georg; Kasper, Manuel; Hinterdorfer, Peter; Brinciotti, Enrico; Rankl, Christian; Kienberger, Ferry; Lucibello, Andrea; Marcelli, Romolo; Patil, Samadhan B.; Giridharagopal, Rajiv

    2015-01-01

    The capability of scanning microwave microscopy for calibrated sub-surface and non-contact capacitance imaging of silicon (Si) samples is quantitatively studied at broadband frequencies ranging from 1 to 20 GHz. Calibrated capacitance images of flat Si test samples with varying dopant density (10 15 –10 19 atoms cm −3 ) and covered with dielectric thin films of SiO 2 (100–400 nm thickness) are measured to demonstrate the sensitivity of scanning microwave microscopy (SMM) for sub-surface imaging. Using standard SMM imaging conditions the dopant areas could still be sensed under a 400 nm thick oxide layer. Non-contact SMM imaging in lift-mode and constant height mode is quantitatively demonstrated on a 50 nm thick SiO 2 test pad. The differences between non-contact and contact mode capacitances are studied with respect to the main parameters influencing the imaging contrast, namely the probe tip diameter and the tip–sample distance. Finite element modelling was used to further analyse the influence of the tip radius and the tip–sample distance on the SMM sensitivity. The understanding of how the two key parameters determine the SMM sensitivity and quantitative capacitances represents an important step towards its routine application for non-contact and sub-surface imaging. (paper)

  1. AFM imaging of bacteria in liquid media immobilized on gelatin coated mica surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Doktycz, M.J.; Sullivan, C.J.; Hoyt, P.R.; Pelletier, D.A.; Wu, S.; Allison, D.P

    2003-10-15

    Immobilization of particulates, especially biomolecules and cells, onto surfaces is critical for imaging with the atomic force microscope (AFM). In this paper, gelatin coated mica surfaces are shown to be suitable for immobilizing and imaging both gram positive, Staphylococcus aureus, and gram negative, Escherichia coli, bacteria in both air and liquid environments. Gelatin coated surfaces are shown to be superior to poly-L-lysine coated surfaces that are commonly used for the immobilization of cells. This cell immobilization technique is being developed primarily for live cell imaging of Rhodopseudomonas palustris. The genome of R. palustris has been sequenced and the organism is the target of intensive studies aimed at understanding genome function. Images of R. palustris grown both aerobically and anaerobically in liquid media are presented. Images in liquid media show the bacteria is rod shaped and smooth while images in air show marked irregularity and folding of the surface. Significant differences in the vertical dimension are also apparent with the height of the bacteria in liquid being substantially greater than images taken in air. In air immobilized bacterial flagella are clearly seen while in liquid this structure is not visible. Additionally, significant morphological differences are observed that depend on the method of bacterial growth.

  2. Ultrasonic phased array with surface acoustic wave for imaging cracks

    Directory of Open Access Journals (Sweden)

    Yoshikazu Ohara

    2017-06-01

    Full Text Available To accurately measure crack lengths, we developed a real-time surface imaging method (SAW PA combining an ultrasonic phased array (PA with a surface acoustic wave (SAW. SAW PA using a Rayleigh wave with a high sensitivity to surface defects was implemented for contact testing using a wedge with the third critical angle that allows the Rayleigh wave to be generated. Here, to realize high sensitivity imaging, SAW PA was optimized in terms of the wedge and the imaging area. The improved SAW PA was experimentally demonstrated using a fatigue crack specimen made of an aluminum alloy. For further verification in more realistic specimens, SAW PA was applied to stainless-steel specimens with a fatigue crack and stress corrosion cracks (SCCs. The fatigue crack was visualized with a high signal-to-noise ratio (SNR and its length was measured with a high accuracy of better than 1 mm. The SCCs generated in the heat-affected zones (HAZs of a weld were successfully visualized with a satisfactory SNR, although responses at coarse grains appeared throughout the imaging area. The SCC lengths were accurately measured. The imaging results also precisely showed complicated distributions of SCCs, which were in excellent agreement with the optically observed distributions.

  3. Segmentation of 3D ultrasound computer tomography reflection images using edge detection and surface fitting

    Science.gov (United States)

    Hopp, T.; Zapf, M.; Ruiter, N. V.

    2014-03-01

    An essential processing step for comparison of Ultrasound Computer Tomography images to other modalities, as well as for the use in further image processing, is to segment the breast from the background. In this work we present a (semi-) automated 3D segmentation method which is based on the detection of the breast boundary in coronal slice images and a subsequent surface fitting. The method was evaluated using a software phantom and in-vivo data. The fully automatically processed phantom results showed that a segmentation of approx. 10% of the slices of a dataset is sufficient to recover the overall breast shape. Application to 16 in-vivo datasets was performed successfully using semi-automated processing, i.e. using a graphical user interface for manual corrections of the automated breast boundary detection. The processing time for the segmentation of an in-vivo dataset could be significantly reduced by a factor of four compared to a fully manual segmentation. Comparison to manually segmented images identified a smoother surface for the semi-automated segmentation with an average of 11% of differing voxels and an average surface deviation of 2mm. Limitations of the edge detection may be overcome by future updates of the KIT USCT system, allowing a fully-automated usage of our segmentation approach.

  4. Scanning tunnelling microscope imaging of nanoscale electron density gradients on the surface of GaAs

    International Nuclear Information System (INIS)

    Hamilton, B; Jacobs, J; Missous, M

    2003-01-01

    This paper is concerned with the scanning tunnelling microscope tunnelling conditions needed to produce constant current images dominated either by surface topology or by electronic effects. A model experimental structure was produced by cleaving a GaAs multiδ-doped layer in UHV and so projecting a spatially varying electron gas density onto the (110) surface. This cross sectional electron density varies on a nanometre scale in the [100] growth direction. The electronic structure and tunnelling properties of this system were modelled, and the tunnelling conditions favouring sensitivity to the surface electron gas density determined

  5. High-speed Imaging of Global Surface Temperature Distributions on Hypersonic Ballistic-Range Projectiles

    Science.gov (United States)

    Wilder, Michael C.; Reda, Daniel C.

    2004-01-01

    The NASA-Ames ballistic range provides a unique capability for aerothermodynamic testing of configurations in hypersonic, real-gas, free-flight environments. The facility can closely simulate conditions at any point along practically any trajectory of interest experienced by a spacecraft entering an atmosphere. Sub-scale models of blunt atmospheric entry vehicles are accelerated by a two-stage light-gas gun to speeds as high as 20 times the speed of sound to fly ballistic trajectories through an 24 m long vacuum-rated test section. The test-section pressure (effective altitude), the launch velocity of the model (flight Mach number), and the test-section working gas (planetary atmosphere) are independently variable. The model travels at hypersonic speeds through a quiescent test gas, creating a strong bow-shock wave and real-gas effects that closely match conditions achieved during actual atmospheric entry. The challenge with ballistic range experiments is to obtain quantitative surface measurements from a model traveling at hypersonic speeds. The models are relatively small (less than 3.8 cm in diameter), which limits the spatial resolution possible with surface mounted sensors. Furthermore, since the model is in flight, surface-mounted sensors require some form of on-board telemetry, which must survive the massive acceleration loads experienced during launch (up to 500,000 gravities). Finally, the model and any on-board instrumentation will be destroyed at the terminal wall of the range. For these reasons, optical measurement techniques are the most practical means of acquiring data. High-speed thermal imaging has been employed in the Ames ballistic range to measure global surface temperature distributions and to visualize the onset of transition to turbulent-flow on the forward regions of hypersonic blunt bodies. Both visible wavelength and infrared high-speed cameras are in use. The visible wavelength cameras are intensified CCD imagers capable of integration

  6. Surface-functionalized nanoparticles for biosensing and imaging-guided therapeutics

    Science.gov (United States)

    Jiang, Shan; Win, Khin Yin; Liu, Shuhua; Teng, Choon Peng; Zheng, Yuangang; Han, Ming-Yong

    2013-03-01

    In this article, the very recent progress of various functional inorganic nanomaterials is reviewed including their unique properties, surface functionalization strategies, and applications in biosensing and imaging-guided therapeutics. The proper surface functionalization renders them with stability, biocompatibility and functionality in physiological environments, and further enables their targeted use in bioapplications after bioconjugation via selective and specific recognition. The surface-functionalized nanoprobes using the most actively studied nanoparticles (i.e., gold nanoparticles, quantum dots, upconversion nanoparticles, and magnetic nanoparticles) make them an excellent platform for a wide range of bioapplications. With more efforts in recent years, they have been widely developed as labeling probes to detect various biological species such as proteins, nucleic acids and ions, and extensively employed as imaging probes to guide therapeutics such as drug/gene delivery and photothermal/photodynamic therapy.

  7. Imaging system design and image interpolation based on CMOS image sensor

    Science.gov (United States)

    Li, Yu-feng; Liang, Fei; Guo, Rui

    2009-11-01

    An image acquisition system is introduced, which consists of a color CMOS image sensor (OV9620), SRAM (CY62148), CPLD (EPM7128AE) and DSP (TMS320VC5509A). The CPLD implements the logic and timing control to the system. SRAM stores the image data, and DSP controls the image acquisition system through the SCCB (Omni Vision Serial Camera Control Bus). The timing sequence of the CMOS image sensor OV9620 is analyzed. The imaging part and the high speed image data memory unit are designed. The hardware and software design of the image acquisition and processing system is given. CMOS digital cameras use color filter arrays to sample different spectral components, such as red, green, and blue. At the location of each pixel only one color sample is taken, and the other colors must be interpolated from neighboring samples. We use the edge-oriented adaptive interpolation algorithm for the edge pixels and bilinear interpolation algorithm for the non-edge pixels to improve the visual quality of the interpolated images. This method can get high processing speed, decrease the computational complexity, and effectively preserve the image edges.

  8. Surface regions of illusory images are detected with a slower processing speed than those of luminance-defined images.

    Science.gov (United States)

    Mihaylova, Milena; Manahilov, Velitchko

    2010-11-24

    Research has shown that the processing time for discriminating illusory contours is longer than for real contours. We know, however, little whether the visual processes, associated with detecting regions of illusory surfaces, are also slower as those responsible for detecting luminance-defined images. Using a speed-accuracy trade-off (SAT) procedure, we measured accuracy as a function of processing time for detecting illusory Kanizsa-type and luminance-defined squares embedded in 2D static luminance noise. The data revealed that the illusory images were detected at slower processing speed than the real images, while the points in time, when accuracy departed from chance, were not significantly different for both stimuli. The classification images for detecting illusory and real squares showed that observers employed similar detection strategies using surface regions of the real and illusory squares. The lack of significant differences between the x-intercepts of the SAT functions for illusory and luminance-modulated stimuli suggests that the detection of surface regions of both images could be based on activation of a single mechanism (the dorsal magnocellular visual pathway). The slower speed for detecting illusory images as compared to luminance-defined images could be attributed to slower processes of filling-in of regions of illusory images within the dorsal pathway.

  9. Utilization of an Airborne Plant Chlorophyll Imaging System for Detection of Septic System Malfunction

    Science.gov (United States)

    Spiering, Bruce A.; Carter, Gregory A.

    2001-01-01

    Malfunctioning, or leaking, sewer systems increase the supply of water and nutrients to surface vegetation. Excess nutrients and harmful bacteria in the effluent pollute ground water and local water bodies and are dangerous to humans and the aquatic ecosystems. An airborne multispectral plant chlorophyll imaging system (PCIS) was used to identify growth patterns in the vegetation covering onsite and public sewer systems. The objective was to evaluate overall performance of the PCIS as well as to determine the best operational configuration for this application. The imaging system was flown in a light aircraft over selected locations Mobile County, Alabama. Calibration panels were used to help characterize instrument performance. Results demonstrated that the PCIS performed well and was capable of detecting septic leakage patterns from altitudes as high as 915 m. From 915 m, 6 of 18 sites were suspected to have sewage leakage. Subsequent ground inspections confirmed leakage on 3 of the 6 sites. From 610 m, 3 of 8 known leakage sites were detected. Tree cover and shadows near residential structures prevented detection of several known malfunctioning systems. Also some leakages known to occur in clear areas were not detected. False detections occurred in areas characterized by surface water drainage problems or recent excavation.

  10. Multi-channel medical imaging system

    Science.gov (United States)

    Frangioni, John V

    2013-12-31

    A medical imaging system provides simultaneous rendering of visible light and fluorescent images. The system may employ dyes in a small-molecule form that remain in the subject's blood stream for several minutes, allowing real-time imaging of the subject's circulatory system superimposed upon a conventional, visible light image of the subject. The system may provide an excitation light source to excite the fluorescent substance and a visible light source for general illumination within the same optical guide used to capture images. The system may be configured for use in open surgical procedures by providing an operating area that is closed to ambient light. The systems described herein provide two or more diagnostic imaging channels for capture of multiple, concurrent diagnostic images and may be used where a visible light image may be usefully supplemented by two or more images that are independently marked for functional interest.

  11. A Novel Algorithm of Surface Eliminating in Undersurface Optoacoustic Imaging

    Directory of Open Access Journals (Sweden)

    Zhulina Yulia V

    2004-01-01

    Full Text Available This paper analyzes the task of optoacoustic imaging of the objects located under the surface covering them. In this paper, we suggest the algorithm of the surface eliminating based on the fact that the intensity of the image as a function of the spatial point should change slowly inside the local objects, and will suffer a discontinuity of the spatial gradients on their boundaries. The algorithm forms the 2-dimensional curves along which the discontinuity of the signal derivatives is detected. Then, the algorithm divides the signal space into the areas along these curves. The signals inside the areas with the maximum level of the signal amplitudes and the maximal gradient absolute values on their edges are put equal to zero. The rest of the signals are used for the image restoration. This method permits to reconstruct the picture of the surface boundaries with a higher contrast than that of the surface detection technique based on the maximums of the received signals. This algorithm does not require any prior knowledge of the signals' statistics inside and outside the local objects. It may be used for reconstructing any images with the help of the signals representing the integral over the object's volume. Simulation and real data are also provided to validate the proposed method.

  12. Innovative Magnetic Resonance Imaging Markers of Hereditary Cerebral Amyloid Angiopathy at 7 Tesla.

    Science.gov (United States)

    Koemans, Emma A; van Etten, Ellis S; van Opstal, Anna M; Labadie, Gerda; Terwindt, Gisela M; Wermer, Marieke J H; Webb, Andrew G; Gurol, Edip M; Greenberg, Steven M; van Buchem, Mark A; van der Grond, Jeroen; van Rooden, Sanneke

    2018-06-01

    The aim of the present study is to explore whether using 7 Tesla magnetic resonance imaging, additional brain changes can be observed in hereditary cerebral hemorrhage with amyloidosis-Dutch type (HCHWA-D) patients as compared with the established magnetic resonance imaging features of sporadic cerebral amyloid angiopathy. The local institutional review board approved this prospective cohort study. In all cases, informed consent was obtained. This prospective parallel cohort study was conducted between 2012 and 2014. We performed T 2 *-weighted magnetic resonance imaging performed at 7 Tesla in presymptomatic mutation carriers (n=11, mean age 35±12 years), symptomatic HCHWA-D patients (n=15, mean age 45±14 years), and in control subjects (n=29, mean age 45±14 years). Images were analyzed for the presence of changes that have not been reported before in sporadic cerebral amyloid angiopathy and HCHWA-D. Innovative observations comprised intragyral hemorrhaging and cortical changes. The presence of these changes was systematically assessed in all participants of the study. Symptomatic HCHWA-D-patients had a higher incidence of intragyral hemorrhage (47% [7/15], controls 0% [0/29], P <0.001), and a higher incidence of specific cortical changes (40% [6/15] versus 0% [0/29], P <0.005). In presymptomatic HCHWA-D-mutation carriers, the prevalence of none of these markers was increased compared with control subjects. The presence of cortical changes and intragyral hemorrhage are imaging features of HCHWA-D that may help recognizing sporadic cerebral amyloid angiopathy in living patients. © 2018 American Heart Association, Inc.

  13. Evaluation of an X-ray-excited optical microscope for chemical imaging of metal and other surfaces.

    Science.gov (United States)

    Sabbe, Pieter-Jan; Dowsett, Mark; Hand, Matthew; Grayburn, Rosie; Thompson, Paul; Bras, Wim; Adriaens, Annemie

    2014-12-02

    The application of a modular system for the nondestructive chemical imaging of metal and other surfaces is described using heritage metals as an example. The custom-built X-ray-excited optical luminescence (XEOL) microscope, XEOM 1, images the chemical state and short-range atomic order of the top 200 nm of both amorphous and crystalline surfaces. A broad X-ray beam is used to illuminate large areas (up to 4 mm(2)) of the sample, and the resulting XEOL emission is collected simultaneously for each pixel by a charge-coupled device sensor to form an image. The input X-ray energy is incremented across a range typical for the X-ray absorption near-edge structure (XANES) and an image collected for each increment. The use of large-footprint beams combined with parallel detection allows the power density to be kept low and facilitates complete nondestructive XANES mapping on a reasonable time scale. In this study the microscope was evaluated by imaging copper surfaces with well-defined patterns of different corrosion products (cuprite Cu2O and nantokite CuCl). The images obtained show chemical contrast, and filtering the XEOL light allowed different corrosion products to be imaged separately. Absorption spectra extracted from software-selected regions of interest exhibit characteristic XANES fingerprints for the compounds present. Moreover, when the X-ray absorption edge positions were extracted from each spectrum, an oxidation state map of the sample could be compiled. The results show that this method allows one to obtain nondestructive and noninvasive information at the micrometer scale while using full-field imaging.

  14. Application of image recognition algorithms for statistical description of nano- and microstructured surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Mărăscu, V.; Dinescu, G. [National Institute for Lasers, Plasma and Radiation Physics, 409 Atomistilor Street, Bucharest– Magurele (Romania); Faculty of Physics, University of Bucharest, 405 Atomistilor Street, Bucharest-Magurele (Romania); Chiţescu, I. [Faculty of Mathematics and Computer Science, University of Bucharest, 14 Academiei Street, Bucharest (Romania); Barna, V. [Faculty of Physics, University of Bucharest, 405 Atomistilor Street, Bucharest-Magurele (Romania); Ioniţă, M. D.; Lazea-Stoyanova, A.; Mitu, B., E-mail: mitub@infim.ro [National Institute for Lasers, Plasma and Radiation Physics, 409 Atomistilor Street, Bucharest– Magurele (Romania)

    2016-03-25

    In this paper we propose a statistical approach for describing the self-assembling of sub-micronic polystyrene beads on silicon surfaces, as well as the evolution of surface topography due to plasma treatments. Algorithms for image recognition are used in conjunction with Scanning Electron Microscopy (SEM) imaging of surfaces. In a first step, greyscale images of the surface covered by the polystyrene beads are obtained. Further, an adaptive thresholding method was applied for obtaining binary images. The next step consisted in automatic identification of polystyrene beads dimensions, by using Hough transform algorithm, according to beads radius. In order to analyze the uniformity of the self–assembled polystyrene beads, the squared modulus of 2-dimensional Fast Fourier Transform (2- D FFT) was applied. By combining these algorithms we obtain a powerful and fast statistical tool for analysis of micro and nanomaterials with aspect features regularly distributed on surface upon SEM examination.

  15. Application of image recognition algorithms for statistical description of nano- and microstructured surfaces

    International Nuclear Information System (INIS)

    Mărăscu, V.; Dinescu, G.; Chiţescu, I.; Barna, V.; Ioniţă, M. D.; Lazea-Stoyanova, A.; Mitu, B.

    2016-01-01

    In this paper we propose a statistical approach for describing the self-assembling of sub-micronic polystyrene beads on silicon surfaces, as well as the evolution of surface topography due to plasma treatments. Algorithms for image recognition are used in conjunction with Scanning Electron Microscopy (SEM) imaging of surfaces. In a first step, greyscale images of the surface covered by the polystyrene beads are obtained. Further, an adaptive thresholding method was applied for obtaining binary images. The next step consisted in automatic identification of polystyrene beads dimensions, by using Hough transform algorithm, according to beads radius. In order to analyze the uniformity of the self–assembled polystyrene beads, the squared modulus of 2-dimensional Fast Fourier Transform (2- D FFT) was applied. By combining these algorithms we obtain a powerful and fast statistical tool for analysis of micro and nanomaterials with aspect features regularly distributed on surface upon SEM examination.

  16. Dual analyzer system for surface analysis dedicated for angle-resolved photoelectron spectroscopy at liquid surfaces and interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Niedermaier, Inga; Kolbeck, Claudia; Steinrück, Hans-Peter; Maier, Florian, E-mail: florian.maier@fau.de [Lehrstuhl für Physikalische Chemie II, FAU Universität Erlangen-Nürnberg, Egerlandstraße 3, 91058 Erlangen (Germany)

    2016-04-15

    The investigation of liquid surfaces and interfaces with the powerful toolbox of ultra-high vacuum (UHV)-based surface science techniques generally has to overcome the issue of liquid evaporation within the vacuum system. In the last decade, however, new classes of liquids with negligible vapor pressure at room temperature—in particular, ionic liquids (ILs)—have emerged for surface science studies. It has been demonstrated that particularly angle-resolved X-ray Photoelectron Spectroscopy (ARXPS) allows for investigating phenomena that occur at gas-liquid and liquid-solid interfaces on the molecular level. The results are not only relevant for IL systems but also for liquids in general. In all of these previous ARXPS studies, the sample holder had to be tilted in order to change the polar detection angle of emitted photoelectrons, which restricted the liquid systems to very thin viscous IL films coating a flat solid support. We now report on the concept and realization of a new and unique laboratory “Dual Analyzer System for Surface Analysis (DASSA)” which enables fast ARXPS, UV photoelectron spectroscopy, imaging XPS, and low-energy ion scattering at the horizontal surface plane of macroscopically thick non-volatile liquid samples. It comprises a UHV chamber equipped with two electron analyzers mounted for simultaneous measurements in 0° and 80° emission relative to the surface normal. The performance of DASSA on a first macroscopic liquid system will be demonstrated.

  17. Dual analyzer system for surface analysis dedicated for angle-resolved photoelectron spectroscopy at liquid surfaces and interfaces

    International Nuclear Information System (INIS)

    Niedermaier, Inga; Kolbeck, Claudia; Steinrück, Hans-Peter; Maier, Florian

    2016-01-01

    The investigation of liquid surfaces and interfaces with the powerful toolbox of ultra-high vacuum (UHV)-based surface science techniques generally has to overcome the issue of liquid evaporation within the vacuum system. In the last decade, however, new classes of liquids with negligible vapor pressure at room temperature—in particular, ionic liquids (ILs)—have emerged for surface science studies. It has been demonstrated that particularly angle-resolved X-ray Photoelectron Spectroscopy (ARXPS) allows for investigating phenomena that occur at gas-liquid and liquid-solid interfaces on the molecular level. The results are not only relevant for IL systems but also for liquids in general. In all of these previous ARXPS studies, the sample holder had to be tilted in order to change the polar detection angle of emitted photoelectrons, which restricted the liquid systems to very thin viscous IL films coating a flat solid support. We now report on the concept and realization of a new and unique laboratory “Dual Analyzer System for Surface Analysis (DASSA)” which enables fast ARXPS, UV photoelectron spectroscopy, imaging XPS, and low-energy ion scattering at the horizontal surface plane of macroscopically thick non-volatile liquid samples. It comprises a UHV chamber equipped with two electron analyzers mounted for simultaneous measurements in 0° and 80° emission relative to the surface normal. The performance of DASSA on a first macroscopic liquid system will be demonstrated.

  18. Error analysis of marker-based object localization using a single-plane XRII

    International Nuclear Information System (INIS)

    Habets, Damiaan F.; Pollmann, Steven I.; Yuan, Xunhua; Peters, Terry M.; Holdsworth, David W.

    2009-01-01

    The role of imaging and image guidance is increasing in surgery and therapy, including treatment planning and follow-up. Fluoroscopy is used for two-dimensional (2D) guidance or localization; however, many procedures would benefit from three-dimensional (3D) guidance or localization. Three-dimensional computed tomography (CT) using a C-arm mounted x-ray image intensifier (XRII) can provide high-quality 3D images; however, patient dose and the required acquisition time restrict the number of 3D images that can be obtained. C-arm based 3D CT is therefore limited in applications for x-ray based image guidance or dynamic evaluations. 2D-3D model-based registration, using a single-plane 2D digital radiographic system, does allow for rapid 3D localization. It is our goal to investigate - over a clinically practical range - the impact of x-ray exposure on the resulting range of 3D localization precision. In this paper it is assumed that the tracked instrument incorporates a rigidly attached 3D object with a known configuration of markers. A 2D image is obtained by a digital fluoroscopic x-ray system and corrected for XRII distortions (±0.035 mm) and mechanical C-arm shift (±0.080 mm). A least-square projection-Procrustes analysis is then used to calculate the 3D position using the measured 2D marker locations. The effect of x-ray exposure on the precision of 2D marker localization and on 3D object localization was investigated using numerical simulations and x-ray experiments. The results show a nearly linear relationship between 2D marker localization precision and the 3D localization precision. However, a significant amplification of error, nonuniformly distributed among the three major axes, occurs, and that is demonstrated. To obtain a 3D localization error of less than ±1.0 mm for an object with 20 mm marker spacing, the 2D localization precision must be better than ±0.07 mm. This requirement was met for all investigated nominal x-ray exposures at 28 cm FOV, and

  19. Infrared photothermal imaging spectroscopy for detection of trace explosives on surfaces.

    Science.gov (United States)

    Kendziora, Christopher A; Furstenberg, Robert; Papantonakis, Michael; Nguyen, Viet; Byers, Jeff; Andrew McGill, R

    2015-11-01

    We are developing a technique for the standoff detection of trace explosives on relevant substrate surfaces using photothermal infrared (IR) imaging spectroscopy (PT-IRIS). This approach leverages one or more compact IR quantum cascade lasers, which are tuned to strong absorption bands in the analytes and directed to illuminate an area on a surface of interest. An IR focal plane array is used to image the surface and detect increases in thermal emission upon laser illumination. The PT-IRIS signal is processed as a hyperspectral image cube comprised of spatial, spectral, and temporal dimensions as vectors within a detection algorithm. The ability to detect trace analytes at standoff on relevant substrates is critical for security applications but is complicated by the optical and thermal analyte/substrate interactions. This manuscript describes a series of PT-IRIS experimental results and analysis for traces of RDX, TNT, ammonium nitrate, and sucrose on steel, polyethylene, glass, and painted steel panels. We demonstrate detection at surface mass loadings comparable with fingerprint depositions ( 10μg/cm2 to 100μg/cm2) from an area corresponding to a single pixel within the thermal image.

  20. Impact of weight loss on markers of systemic inflammation in obese ...

    African Journals Online (AJOL)

    Background: Weight loss studies were conducted in children without asthma have demonstrated a reduction in systemic inflammation. However, the impact of weight loss in the obese paediatric population with asthma has not been investigated. Objective: To measure the effects of weight loss on markers of systemic ...

  1. SU-F-I-11: Software Development for 4D-CBCT Research of Real-Time-Image Gated Spot Scanning Proton Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, T; Fujii, Y; Shimizu, S; Shirato, H [Graduate School of Medicine, Hokkaido University, Sapporo, Hokkaido (Japan); Matsuura, T; Umegaki, K [Faculty of Engineering, Hokkaido University, Sapporo, Hokkaido (Japan); Takao, S; Miyamoto, N; Matsuzaki, Y [Proton Beam Therapy Center, Hokkaido University Hospital, Sapporo, Hokkaido (Japan)

    2016-06-15

    Purpose: To acquire correct information for inside the body in patient positioning of Real-time-image Gated spot scanning Proton Therapy (RGPT), utilization of tomographic image at exhale phase of patient respiration obtained from 4-dimensional Cone beam CT (4D-CBCT) has been desired. We developed software named “Image Analysis Platform” for 4D-CBCT researches which has technique to segment projection-images based on 3D marker position in the body. The 3D marker position can be obtained by using two axes CBCT system at Hokkaido University Hospital Proton Therapy Center. Performance verification of the software was implemented. Methods: The software calculates 3D marker position retrospectively by using matching positions on pair projection-images obtained by two axes fluoroscopy mode of CBCT system. Log data of 3D marker tracking are outputted after the tracking. By linking the Log data and gantry-angle file of projection-image, all projection-images are equally segmented to spatial five-phases according to marker 3D position of SI direction and saved to specified phase folder. Segmented projection-images are used for CBCT reconstruction of each phase. As performance verification of the software, test of segmented projection-images was implemented for sample CT phantom (Catphan) image acquired by two axes fluoroscopy mode of CBCT. Dummy marker was added on the images. Motion of the marker was modeled to move in 3D space. Motion type of marker is sin4 wave function has amplitude 10.0 mm/5.0 mm/0 mm, cycle 4 s/4 s/0 s for SI/AP/RL direction. Results: The marker was tracked within 0.58 mm accuracy in 3D for all images, and it was confirmed that all projection-images were segmented and saved to each phase folder correctly. Conclusion: We developed software for 4D-CBCT research which can segment projection-image based on 3D marker position. It will be helpful to create high quality of 4D-CBCT reconstruction image for RGPT.

  2. Macro-carriers of plastic deformation of steel surface layers detected by digital image correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kopanitsa, D. G., E-mail: kopanitsa@mail.ru; Ustinov, A. M., E-mail: artemustinov@mail.ru [Tomsk State University of Architecture and Building, 2 Solyanaya Sq, Tomsk, 634003 (Russian Federation); Potekaev, A. I., E-mail: potekaev@spti.tsu.ru [National Research Tomsk State University, 36 Lenin Ave., Tomsk, 634050 (Russian Federation); Klopotov, A. A., E-mail: klopotovaa@tsuab.ru [Tomsk State University of Architecture and Building, 2 Solyanaya Sq, Tomsk, 634003 (Russian Federation); National Research Tomsk State University, 36 Lenin Ave., Tomsk, 634050 (Russian Federation); Kopanitsa, G. D., E-mail: georgy.kopanitsa@mail.com [National Research Tomsk Polytechnic University, 30 Lenin Ave., Tomsk, 634050 (Russian Federation)

    2016-01-15

    This paper presents a study of characteristics of an evolution of deformation fields in surface layers of medium-carbon low-alloy specimens under compression. The experiments were performed on the “Universal Testing Machine 4500” using a digital stereoscopic image processing system Vic-3D. A transition between stages is reflected as deformation redistribution on the near-surface layers. Electronic microscopy shows that the structure of the steel is a mixture of pearlite and ferrite grains. A proportion of pearlite is 40% and ferrite is 60%.

  3. Cervix Motion in 50 Cervical Cancer Patients Assessed by Daily Cone Beam Computed Tomographic Imaging of a New Type of Marker

    Energy Technology Data Exchange (ETDEWEB)

    Langerak, Thomas, E-mail: t.langerak@erasmusmc.nl; Mens, Jan Willem; Quint, Sandra; Bondar, Luiza; Heijkoop, Sabrina; Heijmen, Ben; Hoogeman, Mischa

    2015-11-01

    Purpose: To evaluate a new type of marker and a new method of marker implantation and to assess interfraction cervix motion for a large population of patients with locally advanced cervical cancer by daily cone beam computed tomographic (CBCT) imaging. Methods and Materials: We investigated the position of markers in 50 patients treated in prone position during at least 23 fractions. To reduce streaking artifacts in the planning CT scan, a new type of polymeric marker was used and compared with conventional gold markers. In addition, a new method of implantation was used in an attempt to reduce marker loss. In each fraction, a CT scan was acquired before dose delivery and aligned to the bony anatomy of the planning CT scan, simulating the clinical setup protocol. First, sufficient visibility of the markers was verified. Then, systematic and random displacement of the marker centroids was recorded and analyzed in 3 directions with regard to the planning CT and the first CBCT (to evaluate the presence of a vaginal catheter in the planning CT). Streaking artifacts were quantified with the standard deviation of the mean squared intensity difference in a radius around the marker. Results: Marker loss was minimal during treatment: in only 3 of the 50 patients 1 marker was lost. Streaking artifacts for the new markers were reduced compared with conventional gold markers. For the planning CT, M/Σ/σ were 0.4/3.4/2.2 mm, 1.0/5.5/4.5 mm, and −3.9/5.1/3.6 mm for the left-right, anterior-posterior, and cranial-caudal directions, respectively. With regard to the first CBCT scan, M/Σ/σ were 0.8/2.8/2.1, 0.6/4.4/4.4, and −1.3/4.5/3.6 mm. Conclusions: A new type of marker and implantation method was shown to have significantly reduced marker loss and streaking artifacts compared with gold fiducial markers. The recorded marker displacement confirms results reported in the existing literature but for a larger dataset.

  4. Quality control of a kV cone beam computed tomography imaging system

    International Nuclear Information System (INIS)

    Marguet, M.; Bodez, V.

    2009-01-01

    Purpose: This work presents the introduction of a quality assurance program for the On-Board Imager (O.B.I., Varian) kV cone beam computed tomography (kV C.B.C.T.) system, together with the results of 1 year monthly testing. Materials and methods: Firstly the geometric precision and stability of the equipment and of the associated software were evaluated using the Marker phantom. The coincidence of the accelerator isocenter and the imager isocenter was verified as well as the accuracy of the registration of kV cone beam computed tomography (kV C.B.C.T.) with reference CT images. Then, the kV C.B.C.T. image quality was evaluated using the Catphan 504 phantom and ArtiScan software (Aquilab) for both full-fan (F.F.) and half-fan (H.F.) imaging modes. Results: The kV C.B.C.T. isocenter and image registration with correction of the table position were found to be within a tolerance of 2.0 mm. Concerning the kV C.B.C.T. image quality, image noise and uniformity, the Hounsfield units (HU) stability and linearity, geometric distortion and high contrast resolution were all found to be within the manufacturer's recommendations for both F.F. and H.F. modes. However, the low contrast resolution for the HF mode did not meet the manufacturer's specifications. Conclusion: The quality assurance tests introduced have defined the initial system characteristics and their evolution during a period of 1 year, demonstrating the stability of the O.B.I.. (authors)

  5. Expression of Lipid Peroxidation Markers in the Tear Film and Ocular Surface of Patients with Non-Sjogren Syndrome: Potential Biomarkers for Dry Eye Disease.

    Science.gov (United States)

    Choi, Won; Lian, Cui; Ying, Li; Kim, Ga Eon; You, In Cheon; Park, Soo Hyun; Yoon, Kyung Chul

    2016-09-01

    To investigate the expression of lipid peroxidation markers in the tear film and ocular surface and their correlation with disease severity in patients with dry eye disease. The concentrations of hexanoyl-lysine (HEL), 4-hydroxy-2-nonenal (HNE), and malondialdehyde (MDA) were measured with enzyme-linked immunosorbent assays in tears obtained from 44 patients with non-Sjogren syndrome dry eye and 33 control subjects. The correlations between the marker levels and the tear film and ocular surface parameters, including tear film break-up time (BUT), Schirmer tear value, tear clearance rate, keratoepitheliopathy scores, corneal sensitivity, conjunctival goblet cell density, and symptom score, were analyzed. The expression of the lipid peroxidation markers HEL, 4-HNE, and MDA in the conjunctiva was evaluated using immunohistochemistry. The concentrations of HEL, 4-HNE, and MDA were 279.84 ± 69.98 nmol/L, 0.02 ± 0.01 μg/mL, and 3.80 ± 1.05 pmol/mg in control subjects and 283.21 ± 89.67 nmol/L (p = 0.97), 0.20 ± 0.03 μg/mL (p dry eye patients. 4-HNE and MDA levels significantly correlated with BUT, Schirmer tear value, tear clearance rate, keratoepitheliopathy scores, conjunctival goblet cell density, and symptom score (p dry eye patients. The expression of late lipid peroxidation markers, 4-HNE and MDA, increases in the tear film and ocular surface of patients with dry eye. The levels correlate with various tear film and ocular surface parameters and may reflect the severity of dry eye disease.

  6. Image findings and bone metabolic markers of bone involvement by oral squamous cell carcinoma

    International Nuclear Information System (INIS)

    Kameta, Ayako; Tsuchimochi, Makoto; Harada, Mikiko; Katada, Tsutomu; Sasaki, Yoshihiko; Hayama, Kazuhide

    2000-01-01

    Recently it has been reported that the circulating pyridinoline cross-linked carboxyl-terminal telopeptide of type I collagen (ICTP) and carboxyl-terminal propeptide of type I procollagen (PICP) are useful markers for detecting metastasis of malignancies to bone. Since ICTP and PICP are related to collagen metabolism, respectively breaking down and synthesizing type I collagen, elevated blood concentrations of these markers may reflect direct jaw bone destruction by oral cancer. The purpose of this study was to clarify the relationship between serum ICTP and PICP levels and bone invasion associated with oral cancer. Bone invasion was evaluated in 41 patients with oral squamous cell carcinoma (SCC) by panoramic radiography and 99m Tc-methylene diphosphonate (MDP) scintigraphy. We also assayed serum levels of parathyroid hormone-related protein (PTHrP) and compared them with concentrations of bone metabolic markers and imaging findings. There was no significant relationship between serum ICTP and PICP levels and bone invasion. However, in three of the five cases that showed remarkably high serum ICTP levels, 99m Tc-MDP uptake in the lesion was intensely increased. This suggests that serum ICTP levels may be elevated when bone metabolic changes caused by cancer involving the bone are extensive. We could find no significant correlation among serum levels of ICTP, PICP, and PTHrP. ICTP and PICP do not appear to be good indicators of direct bone invasion by oral SCC in early stages. (author)

  7. Microscopic image processing system for measuring nonuniform film thickness profiles: Image scanning ellipsometry

    International Nuclear Information System (INIS)

    Liu, A.H.; Plawsky, J.L.; Wayner, P.C. Jr.

    1993-01-01

    The long-term objective of this research program is to determine the stability and heat transfer characteristics of evaporating thin films. The current objective is to develop and use a microscopic image-processing system (IPS) which has two parts: an image analyzing interferometer (IAI) and an image scanning ellipsometer (ISE). The primary purpose of this paper is to present the basic concept of ISE, which is a novel technique to measure the two dimensional thickness profile of a non-uniform, thin film, from several nm up to several μm, in a steady state as well as in a transient state. It is a full-field imaging technique which can study every point on the surface simultaneously with high spatial resolution and thickness sensitivity, i.e., it can measure and map the 2-D film thickness profile. The ISE was tested by measuring the thickness profile and the refractive index of a nonuniform solid film

  8. From quality markers to data mining and intelligence assessment: A smart quality-evaluation strategy for traditional Chinese medicine based on quality markers.

    Science.gov (United States)

    Bai, Gang; Zhang, Tiejun; Hou, Yuanyuan; Ding, Guoyu; Jiang, Min; Luo, Guoan

    2018-01-31

    The quality of traditional Chinese medicine (TCM) forms the foundation of its clinical efficacy. The standardization of TCM is the most important task of TCM modernization. In recent years, there has been great progress in the quality control of TCM. However, there are still many issues related to the current quality standards, and it is difficult to objectively evaluate and effectively control the quality of TCM. To face these challenge, we summarized the current quality marker (Q-marker) research based on its characteristics and benefits, and proposed a reasonable and intelligentized quality evaluation strategy for the development and application of Q-markers. Ultra-performance liquid chromatography-quadrupole/time-of-flight with partial least squares-discriminant analysis was suggested to screen the chemical markers from Chinese medicinal materials (CMM), and a bioactive-guided evaluation method was used to select the Q-markers. Near-infrared spectroscopy (NIRS), based on the distinctive wavenumber zones or points from the Q-markers, was developed for its determination. Then, artificial intelligence algorithms were used to clarify the complex relationship between the Q-markers and their integral functions. Internet and mobile communication technology helped us to perform remote analysis and determine the information feedback of test samples. The quality control research, evaluation, standard establishment and quality control of TCM must be based on the systematic analysis of Q-markers to study and describe the material basis of TCM efficacy, define the chemical markers in the plant body, and understand the process of herb drug acquisition, change and transmission laws affecting metabolism and exposure. Based on the advantages of chemometrics, new sensor technologies, including infrared spectroscopy, hyperspectral imaging, chemical imaging, electronic nose and electronic tongue, have become increasingly important in the quality evaluation of CMM. Inspired by the

  9. Conversion of a Surface Model of a Structure of Interest into a Volume Model for Medical Image Retrieval

    Directory of Open Access Journals (Sweden)

    Sarmad ISTEPHAN

    2015-06-01

    Full Text Available Volumetric medical image datasets contain vital information for noninvasive diagnosis, treatment planning and prognosis. However, direct and unlimited query of such datasets is hindered due to the unstructured nature of the imaging data. This study is a step towards the unlimited query of medical image datasets by focusing on specific Structures of Interest (SOI. A requirement in achieving this objective is having both the surface and volume models of the SOI. However, typically, only the surface model is available. Therefore, this study focuses on creating a fast method to convert a surface model to a volume model. Three methods (1D, 2D and 3D are proposed and evaluated using simulated and real data of Deep Perisylvian Area (DPSA within the human brain. The 1D method takes 80 msec for DPSA model; about 4 times faster than 2D method and 7.4 fold faster than 3D method, with over 97% accuracy. The proposed 1D method is feasible for surface to volume conversion in computer aided diagnosis, treatment planning and prognosis systems containing large amounts of unstructured medical images.

  10. Validation of phalanx bone three-dimensional surface segmentation from computed tomography images using laser scanning

    International Nuclear Information System (INIS)

    DeVries, Nicole A.; Gassman, Esther E.; Kallemeyn, Nicole A.; Shivanna, Kiran H.; Magnotta, Vincent A.; Grosland, Nicole M.

    2008-01-01

    To examine the validity of manually defined bony regions of interest from computed tomography (CT) scans. Segmentation measurements were performed on the coronal reformatted CT images of the three phalanx bones of the index finger from five cadaveric specimens. Two smoothing algorithms (image-based and Laplacian surface-based) were evaluated to determine their ability to represent accurately the anatomic surface. The resulting surfaces were compared with laser surface scans of the corresponding cadaveric specimen. The average relative overlap between two tracers was 0.91 for all bones. The overall mean difference between the manual unsmoothed surface and the laser surface scan was 0.20 mm. Both image-based and Laplacian surface-based smoothing were compared; the overall mean difference for image-based smoothing was 0.21 mm and 0.20 mm for Laplacian smoothing. This study showed that manual segmentation of high-contrast, coronal, reformatted, CT datasets can accurately represent the true surface geometry of bones. Additionally, smoothing techniques did not significantly alter the surface representations. This validation technique should be extended to other bones, image segmentation and spatial filtering techniques. (orig.)

  11. Validation of phalanx bone three-dimensional surface segmentation from computed tomography images using laser scanning

    Energy Technology Data Exchange (ETDEWEB)

    DeVries, Nicole A.; Gassman, Esther E.; Kallemeyn, Nicole A. [The University of Iowa, Department of Biomedical Engineering, Center for Computer Aided Design, Iowa City, IA (United States); Shivanna, Kiran H. [The University of Iowa, Center for Computer Aided Design, Iowa City, IA (United States); Magnotta, Vincent A. [The University of Iowa, Department of Biomedical Engineering, Department of Radiology, Center for Computer Aided Design, Iowa City, IA (United States); Grosland, Nicole M. [The University of Iowa, Department of Biomedical Engineering, Department of Orthopaedics and Rehabilitation, Center for Computer Aided Design, Iowa City, IA (United States)

    2008-01-15

    To examine the validity of manually defined bony regions of interest from computed tomography (CT) scans. Segmentation measurements were performed on the coronal reformatted CT images of the three phalanx bones of the index finger from five cadaveric specimens. Two smoothing algorithms (image-based and Laplacian surface-based) were evaluated to determine their ability to represent accurately the anatomic surface. The resulting surfaces were compared with laser surface scans of the corresponding cadaveric specimen. The average relative overlap between two tracers was 0.91 for all bones. The overall mean difference between the manual unsmoothed surface and the laser surface scan was 0.20 mm. Both image-based and Laplacian surface-based smoothing were compared; the overall mean difference for image-based smoothing was 0.21 mm and 0.20 mm for Laplacian smoothing. This study showed that manual segmentation of high-contrast, coronal, reformatted, CT datasets can accurately represent the true surface geometry of bones. Additionally, smoothing techniques did not significantly alter the surface representations. This validation technique should be extended to other bones, image segmentation and spatial filtering techniques. (orig.)

  12. Functional imaging of neurotransmitter systems in movement disorders

    Energy Technology Data Exchange (ETDEWEB)

    Ilgin, N. [Ankara, Gazi Univ. Medical School (Turkey). Dept. of Nuclear Medicine

    1998-09-01

    PET and SPECT enable the direct measurement of components of the dopaminergic and other systems in the living human brain and offer unique opportunity for the in vivo quantification on the dopaminergic function in PD and other movement disorders. The need to establish the early and differential diagnosis of PD is increasingly important given the recent evidence that early pharmacologic intervention may slow progression of this progressive degenerative disease. Accordingly, imaging with PET and SPECT using specific neuro markers has been increasingly important to biochemically identify the loss of specific neurotransmitters, their synthesizing enzymes and their receptors in movement disorders. Through the parallel development of new radiotracers, kinetic models and better instruments, PET and SPECT technology is enabling investigation of increasingly more complex aspects of the human brain neurotransmitter systems. This paper summarizes the results of different PET-SPECT studies used to evaluate the various elements of the dopamine system in the human brain with PET and intends to introduce the newly emerging specific tracers and their applications to clinical research in movement disorders.

  13. Functional imaging of neurotransmitter systems in movement disorders

    International Nuclear Information System (INIS)

    Ilgin, N.

    1998-01-01

    PET and SPECT enable the direct measurement of components of the dopaminergic and other systems in the living human brain and offer unique opportunity for the in vivo quantification on the dopaminergic function in PD and other movement disorders. The need to establish the early and differential diagnosis of PD is increasingly important given the recent evidence that early pharmacologic intervention may slow progression of this progressive degenerative disease. Accordingly, imaging with PET and SPECT using specific neuro markers has been increasingly important to biochemically identify the loss of specific neurotransmitters, their synthesizing enzymes and their receptors in movement disorders. Through the parallel development of new radiotracers, kinetic models and better instruments, PET and SPECT technology is enabling investigation of increasingly more complex aspects of the human brain neurotransmitter systems. This paper summarizes the results of different PET-SPECT studies used to evaluate the various elements of the dopamine system in the human brain with PET and intends to introduce the newly emerging specific tracers and their applications to clinical research in movement disorders

  14. MarsSI: Martian surface data processing information system

    Science.gov (United States)

    Quantin-Nataf, C.; Lozac'h, L.; Thollot, P.; Loizeau, D.; Bultel, B.; Fernando, J.; Allemand, P.; Dubuffet, F.; Poulet, F.; Ody, A.; Clenet, H.; Leyrat, C.; Harrisson, S.

    2018-01-01

    MarsSI (Acronym for Mars System of Information, https://emars.univ-lyon1.fr/MarsSI/, is a web Geographic Information System application which helps managing and processing martian orbital data. The MarsSI facility is part of the web portal called PSUP (Planetary SUrface Portal) developed by the Observatories of Paris Sud (OSUPS) and Lyon (OSUL) to provide users with efficient and easy access to data products dedicated to the martian surface. The portal proposes 1) the management and processing of data thanks to MarsSI and 2) the visualization and merging of high level (imagery, spectral, and topographic) products and catalogs via a web-based user interface (MarsVisu). The portal PSUP as well as the facility MarsVisu is detailed in a companion paper (Poulet et al., 2018). The purpose of this paper is to describe the facility MarsSI. From this application, users are able to easily and rapidly select observations, process raw data via automatic pipelines, and get back final products which can be visualized under Geographic Information Systems. Moreover, MarsSI also contains an automatic stereo-restitution pipeline in order to produce Digital Terrain Models (DTM) on demand from HiRISE (High Resolution Imaging Science Experiment) or CTX (Context Camera) pair-images. This application is funded by the European Union's Seventh Framework Programme (FP7/2007-2013) (ERC project eMars, No. 280168) and has been developed in the scope of Mars, but the design is applicable to any other planetary body of the solar system.

  15. Image quality of digital mammography images produced using wet and dry laser imaging systems

    International Nuclear Information System (INIS)

    Al Khalifah, K.; Brindhaban, A.; AlArfaj, R.; Jassim, O.

    2006-01-01

    Introduction: A study was carried out to compare the quality of digital mammographic images printed or processed by a wet laser imaging system and a dedicated mammographic dry laser imaging system. Material and methods: Digital images of a tissue equivalent breast phantom were obtained using a GE Senographe 2000D digital mammography system and different target/filter combinations of the X-ray tube. These images were printed on films using the Fuji FL-IM D wet laser imaging system and the Kodak DryView 8600 dry laser imaging system. The quality of images was assessed in terms of detectability of microcalcifications and simulated tumour masses by five radiologists. In addition, the contrast index and speed index of the two systems were measured using the step wedge in the phantom. The unpaired, unequal variance t-test was used to test any statistically significant differences. Results: There were no significant (p < 0.05) differences between the images printed using the two systems in terms of microcalcification and tumour mass detectability. The wet system resulted in slightly higher contrast index while the dry system showed significantly higher speed index. Conclusion: Both wet and dry laser imaging systems can produce mammography images of good quality on which 0.2 mm microcalcifications and 2 mm tumour masses can be detected. Dry systems are preferable due to the absence of wet chemical processing and solid or liquid chemical waste. The wet laser imaging systems, however, still represent a useful alternative to dry laser imaging systems for mammography studies

  16. The retrieval of two-dimensional distribution of the earth's surface aerodynamic roughness using SAR image and TM thermal infrared image

    Institute of Scientific and Technical Information of China (English)

    ZHANG; Renhua; WANG; Jinfeng; ZHU; Caiying; SUN; Xiaomin

    2004-01-01

    After having analyzed the requirement on the aerodynamic earth's surface roughness in two-dimensional distribution in the research field of interaction between land surface and atmosphere, this paper presents a new way to calculate the aerodynamic roughness using the earth's surface geometric roughness retrieved from SAR (Synthetic Aperture Radar) and TM thermal infrared image data. On the one hand, the SPM (Small Perturbation Model) was used as a theoretical SAR backscattering model to describe the relationship between the SAR backscattering coefficient and the earth's surface geometric roughness and its dielectric constant retrieved from the physical model between the soil thermal inertia and the soil surface moisture with the simultaneous TM thermal infrared image data and the ground microclimate data. On the basis of the SAR image matching with the TM image, the non-volume scattering surface geometric information was obtained from the SPM model at the TM image pixel scale, and the ground pixel surface's equivalent geometric roughness-height standard RMS (Root Mean Square) was achieved from the geometric information by the transformation of the typical topographic factors. The vegetation (wheat, tree) height retrieved from spectrum model was also transferred into its equivalent geometric roughness. A completely two-dimensional distribution map of the equivalent geometric roughness over the experimental area was produced by the data mosaic technique. On the other hand, according to the atmospheric eddy currents theory, the aerodynamic surface roughness was iterated out with the atmosphere stability correction method using the wind and the temperature profiles data measured at several typical fields such as bare soil field and vegetation field. After having analyzed the effect of surface equivalent geometric roughness together with dynamic and thermodynamic factors on the aerodynamic surface roughness within the working area, this paper first establishes a scale

  17. A preclinical model for noninvasive imaging of hypoxia-induced gene expression; comparison with an exogenous marker of tumor hypoxia

    Energy Technology Data Exchange (ETDEWEB)

    Wen Bixiu; Burgman, Paul; Zanzonico, Pat; O' Donoghue, Joseph; Li, Gloria C.; Ling, C. Clifton [Memorial Sloan-Kettering Cancer Center, Department of Medical Physics, New York (United States); Cai Shangde; Finn, Ron [Memorial Sloan-Kettering Cancer Center, Department of Radiology, New York (United States); Serganova, Inna [Memorial Sloan-Kettering Cancer Center, Department of Neurology, New York (United States); Blasberg, Ronald; Gelovani, Juri [Memorial Sloan-Kettering Cancer Center, Department of Radiology, New York (United States); Memorial Sloan-Kettering Cancer Center, Department of Neurology, New York (United States)

    2004-11-01

    Hypoxia is associated with tumor aggressiveness and is an important cause of resistance to radiation therapy and chemotherapy. Assays of tumor hypoxia could provide selection tools for hypoxia-modifying treatments. The purpose of this study was to develop and characterize a rodent tumor model with a reporter gene construct that would be transactivated by the hypoxia-inducible molecular switch, i.e., the upregulation of HIF-1. The reporter gene construct is the herpes simplex virus 1-thymidine kinase (HSV1-tk) fused with the enhanced green fluorescent protein (eGFP) under the regulation of an artificial hypoxia-responsive enhancer/promoter. In this model, tumor hypoxia would up-regulate HIF-1, and through the hypoxia-responsive promoter transactivate the HSV1-tkeGFPfusion gene. The expression of this reporter gene can be assessed with the {sup 124}I-labeled reporter substrate 2'-fluoro-2'-deoxy-1-{beta}-d-arabinofuranosyl-5-iodouracil ({sup 124}I-FIAU), which is phosphorylated by the HSV1-tk enzyme and trapped in the hypoxic cells. Animal positron emission tomography (microPET) and phosphor plate imaging (PPI) were used in this study to visualize the trapped {sup 124}I-FIAU, providing a distribution of the hypoxia-induced molecular events. The distribution of {sup 124}I-FIAU was also compared with that of an exogenous hypoxic cell marker, {sup 18}F-fluoromisonidazole (FMISO). Our results showed that {sup 124}I-FIAU microPET imaging of the hypoxia-induced reporter gene expression is feasible, and that the intratumoral distributions of {sup 124}I-FIAU and {sup 18}F-FMISO are similar. In tumor sections, detailed radioactivity distributions were obtained with PPI which also showed similarity between {sup 124}I-FIAU and {sup 18}F-FMISO. This reporter system is sufficiently sensitive to detect hypoxia-induced transcriptional activation by noninvasive imaging and might provide a valuable tool in studying tumor hypoxia and in validating existing and future

  18. Combined analysis of surface reflection imaging and vertical seismic profiling at Yucca Mountain, Nevada

    International Nuclear Information System (INIS)

    Daley, T.M.; Majer, E.L.; Karageorgi, E.

    1994-08-01

    This report presents results from surface and borehole seismic profiling performed by the Lawrence Berkeley Laboratory (LBL) on Yucca Mountain. This work was performed as part of the site characterization effort for the potential high-level nuclear waste repository. Their objective was to provide seismic imaging from the near surface (200 to 300 ft. depth) to the repository horizon and below, if possible. Among the issues addressed by this seismic imaging work are location and depth of fracturing and faulting, geologic identification of reflecting horizons, and spatial continuity of reflecting horizons. The authors believe their results are generally positive, with tome specific successes. This was the first attempt at this scale using modem seismic imaging techniques to determine geologic features on Yucca Mountain. The principle purpose of this report is to present the interpretation of the seismic reflection section in a geologic context. Three surface reflection profiles were acquired and processed as part of this study. Because of environmental concerns, all three lines were on preexisting roads. Line 1 crossed the mapped surface trace of the Ghost Dance fault and it was intended to study the dip and depth extent of the fault system. Line 2 was acquired along Drill Hole wash and was intended to help the ESF north ramp design activities. Line 3 was acquired along Yucca Crest and was designed to image geologic horizons which were thought to be less faulted along the ridge. Unfortunately, line 3 proved to have poor data quality, in part because of winds, poor field conditions and limited time. Their processing and interpretation efforts were focused on lines 1 and 2 and their associated VSP studies

  19. A photomultiplier-based secondary electron imaging system for a nuclear microprobe

    International Nuclear Information System (INIS)

    Alves, L.C.; Breese, M.B.H.; Silva, M.F. da; Soares, J.C.

    2002-01-01

    The ability to define, or recognise particular regions of interest or surface features is vital to the analysis and interpretation of spatially-resolved images collected with a nuclear microprobe. However, good topographic image contrast is difficult to accomplish using PIXE or RBS images due to their inherent insensitivity to topography, lack of elemental variation or poor statistics. Topographic image contrast is commonly obtained in scanning electron microscopy (SEM) by detecting a large flux of secondary electrons produced by the focused keV electron beam. Similar systems have not been widely used on nuclear microprobes due to ion beam intensity fluctuations, which limit the minimum resolvable contrast and present a major limitation for this technique. This paper describes a secondary electron imaging system which has been developed on the Lisbon microprobe. It is based on a scintillator, a photomultiplier operated in a pulsed mode, a pulse shaping electronic chain and ADC, and requires no changes to the existing data acquisition system. Examples of the images obtained from materials such as patterned SiGe wafers and hydrogen-implanted silicon are given, and compared with SEM or optical images

  20. A mobile laboratory for surface and subsurface imaging in geo-hazard monitoring activity

    Science.gov (United States)

    Cornacchia, Carmela; Bavusi, Massimo; Loperte, Antonio; Pergola, Nicola; Pignatti, Stefano; Ponzo, Felice; Lapenna, Vincenzo

    2010-05-01

    A new research infrastructure for supporting ground-based remote sensing observations in the different phases of georisk management cycle is presented. This instrumental facility has been designed and realised by TeRN, a public-private consortium on Earth Observations and Natural Risks, in the frame of the project "ImpresAmbiente" funded by Italian Ministry of Research and University. The new infrastructure is equipped with ground-based sensors (hyperspectral cameras, thermal cameras, laser scanning and electromagnetic antennae) able to remotely map physical parameters and/or earth-surface properties (temperature, soil moisture, land cover, etc…) and to illuminate near-surface geological structures (fault, groundwater tables, landslide bodies etc...). Furthermore, the system can be used for non-invasive investigations of architectonic buildings and civil infrastructures (bridges, tunnel, road pavements, etc...) interested by natural and man-made hazards. The hyperspectral cameras can acquire high resolution images of earth-surface and cultural objects. They are operating in the Visible Near InfraRed (0.4÷1.0μm) with 1600 spatial pixel and 3.7nm of spectral sampling and in the Short Wave InfraRed (1.3÷2.5µm) spectral region with 320 spatial pixel and 5nm of spectral sampling. The IR cameras are operating in the Medium Wavelength InfraRed (3÷5µm; 640x512; NETDcultural heritage. As a consequence, laser data can be useful integrated with traditional monitoring techniques. The Laser Scanner is characterized by very high data acquisition repetition rate up to 500.000 pxl/sec with a range resolution of 0.1 mm, vertical and horizontal FoV of 310° and 360° respectively with a resolution of 0.0018°. The system is also equipped with a metric camera allows to georeference the high resolution images acquired. The electromagnetic sensors allow to obtain in near real time high-resolution 2D and 3D subsurface tomographic images. The main components are a fully automatic

  1. Superparamagnetic iron oxide nanoparticle-labeled cells as an effective vehicle for tracking the GFP gene marker using magnetic resonance imaging

    Science.gov (United States)

    Zhang, Z; Mascheri, N; Dharmakumar, R; Fan, Z; Paunesku, T; Woloschak, G; Li, D

    2010-01-01

    Background Detection of a gene using magnetic resonance imaging (MRI) is hindered by the magnetic resonance (MR) targeting gene technique. Therefore it may be advantageous to image gene-expressing cells labeled with superparamagnetic iron oxide (SPIO) nanoparticles by MRI. Methods The GFP-R3230Ac (GFP) cell line was incubated for 24 h using SPIO nanoparticles at a concentration of 20 μg Fe/mL. Cell samples were prepared for iron content analysis and cell function evaluation. The labeled cells were imaged using fluorescent microscopy and MRI. Results SPIO was used to label GFP cells effectively, with no effects on cell function and GFP expression. Iron-loaded GFP cells were successfully imaged with both fluorescent microscopy and T2*-weighted MRI. Prussian blue staining showed intracellular iron accumulation in the cells. All cells were labeled (100% labeling efficiency). The average iron content per cell was 4.75±0.11 pg Fe/cell (P<0.05 versus control). Discussion This study demonstrates that the GFP expression of cells is not altered by the SPIO labeling process. SPIO-labeled GFP cells can be visualized by MRI; therefore, GFP, a gene marker, was tracked indirectly with the SPIO-loaded cells using MRI. The technique holds promise for monitoring the temporal and spatial migration of cells with a gene marker and enhancing the understanding of cell- and gene-based therapeutic strategies. PMID:18956269

  2. Image restoration techniques using Compton backscatter imaging for the detection of buried land mines

    Science.gov (United States)

    Wehlburg, Joseph C.; Keshavmurthy, Shyam P.; Watanabe, Yoichi; Dugan, Edward T.; Jacobs, Alan M.

    1995-06-01

    Earlier landmine imaging systems used two collimated detectors to image objects. These systems had difficulty in distinguishing between surface features and buried features. Using a combination of collimated and uncollimated detectors in a Compton backscatter imaging (CBI) system, allows the identification of surface and buried features. Images created from the collimated detectors contain information about the surface and the buried features, while the uncollimated detectors respond (approximately 80%) to features on the surface. The analysis of surface features are performed first, then these features can be removed and the buried features can be identified. Separation of the surface and buried features permits the use of a globbing algorithm to define regions of interest that can then be quantified [area, Y dimension, X dimension, and center location (xo, yo)]. Mine composition analysis is also possible because of the properties of the four detector system. Distinguishing between a pothole and a mine, that was previously very difficult, can now be easily accomplished.

  3. Imaging of surfaces and defects of crystals. Progress report, May 1, 1978--April 30, 1979

    International Nuclear Information System (INIS)

    Cowley, J.M.

    1979-04-01

    The possibility of obtaining electron diffraction patterns from very small specimen regions combined with high resolution imaging by use of scanning transmission electron microscopy (STEM) allows the detailed study of small nuclei of reaction products or of crystal defects. The capabilities of this method have been extended by the design and construction of a TV system for the viewing and recording of microdiffraction patterns from our STEM instrument so that clear patterns can be obtained from regions as small as 10A in diameter. This system has been applied to the study of initial stages of oxidation of chromium films, revealing the presence of very small oxide nuclei and identifying these crystals as having a previously unsuspected spinel structure. The further stages of growth of oxides on chromium are being investigated. Initial results have also been obtained on the surface structure of oxides such as MgO. The extension of previous work on the diffraction from, and imaging of crystal surfaces by the use of medium-to-low energy electrons (15 to 1 keV) has allowed a much more complete understanding of the contrast-producing mechanisms. Application to the study of pyrolytic graphite surfaces has given a clear picture of the mosaic structure and defect distribution and provided a basis for the more reliable and quantitative general use of these techniques in surface structure analysis

  4. Automated localization of the prostate at the time of treatment using implanted radiopaque markers: technical feasibility

    International Nuclear Information System (INIS)

    Balter, James M.; Kwok, L. Lam; Sandler, Howard M.; Littles, J. Fred; Bree, Robert L.; Ten Haken, Randall K.

    1995-01-01

    Purpose: Prostate movement is a major consideration in the formation of target volumes for conformal radiation therapy of prostate cancer. The goal of this study was to determine the technical feasibility of using implanted radiopaque markers and digital imaging to localize the prostate at the time of treatment, thus allowing for reduction of the margin required for uncertainty in target position. Methods and Materials: Radiopaque markers implanted around the prostate prior to treatment are visible on electronic radiographs generated with a portal imager or diagnostic imaging device. The locations of the images of these markers on the digital radiographs were automatically determined by a template-matching algorithm. The coordinates of the markers were found by projecting rays through the marker locations on orthogonal radiographs using a three-dimensional (3D) point-matching algorithm. Prostate and/or patient movement was inferred from the marker displacements. Images generated from known movements of a phantom with implanted markers were tested with this algorithm. Locations of markers from daily images of patients with implanted markers were determined by both manual and automatic techniques to determine the efficacy of automated localization on typical clinical images. Results: Prostate movements can be automatically detected in a phantom using low-energy photons within 30 s after image acquisition and with a precision of better than 1 mm in translation and 1 deg. in rotation (indistinguishable from the uncertainty in measuring precision). Conclusion: The studies show that on-line repositioning of the patient based on localization of the markers at the time of treatment is feasible, and may reduce the uncertainty in prostate location when combined with practical on-line repositioning techniques

  5. Correlative scanning electron and confocal microscopy imaging of labeled cells coated by indium-tin-oxide

    KAUST Repository

    Rodighiero, Simona

    2015-03-22

    Confocal microscopy imaging of cells allows to visualize the presence of specific antigens by using fluorescent tags or fluorescent proteins, with resolution of few hundreds of nanometers, providing their localization in a large field-of-view and the understanding of their cellular function. Conversely, in scanning electron microscopy (SEM), the surface morphology of cells is imaged down to nanometer scale using secondary electrons. Combining both imaging techniques have brought to the correlative light and electron microscopy, contributing to investigate the existing relationships between biological surface structures and functions. Furthermore, in SEM, backscattered electrons (BSE) can image local compositional differences, like those due to nanosized gold particles labeling cellular surface antigens. To perform SEM imaging of cells, they could be grown on conducting substrates, but obtaining images of limited quality. Alternatively, they could be rendered electrically conductive, coating them with a thin metal layer. However, when BSE are collected to detect gold-labeled surface antigens, heavy metals cannot be used as coating material, as they would mask the BSE signal produced by the markers. Cell surface could be then coated with a thin layer of chromium, but this results in a loss of conductivity due to the fast chromium oxidation, if the samples come in contact with air. In order to overcome these major limitations, a thin layer of indium-tin-oxide was deposited by ion-sputtering on gold-decorated HeLa cells and neurons. Indium-tin-oxide was able to provide stable electrical conductivity and preservation of the BSE signal coming from the gold-conjugated markers. © 2015 Wiley Periodicals, Inc.

  6. Full-field measurement of micromotion around a cementless femoral stem using micro-CT imaging and radiopaque markers.

    Science.gov (United States)

    Malfroy Camine, V; Rüdiger, H A; Pioletti, D P; Terrier, A

    2016-12-08

    A good primary stability of cementless femoral stems is essential for the long-term success of total hip arthroplasty. Experimental measurement of implant micromotion with linear variable differential transformers is commonly used to assess implant primary stability in pre-clinical testing. But these measurements are often limited to a few distinct points at the interface. New techniques based on micro-computed tomography (micro-CT) have recently been introduced, such as Digital Volume Correlation (DVC) or markers-based approaches. DVC is however limited to measurement around non-metallic implants due to metal-induced imaging artifacts, and markers-based techniques are confined to a small portion of the implant. In this paper, we present a technique based on micro-CT imaging and radiopaque markers to provide the first full-field micromotion measurement at the entire bone-implant interface of a cementless femoral stem implanted in a cadaveric femur. Micromotion was measured during compression and torsion. Over 300 simultaneous measurement points were obtained. Micromotion amplitude ranged from 0 to 24µm in compression and from 0 to 49µm in torsion. Peak micromotion was distal in compression and proximal in torsion. The technique bias was 5.1µm and its repeatability standard deviation was 4µm. The method was thus highly reliable and compared well with results obtained with linear variable differential transformers (LVDTs) reported in the literature. These results indicate that this micro-CT based technique is perfectly relevant to observe local variations in primary stability around metallic implants. Possible applications include pre-clinical testing of implants and validation of patient-specific models for pre-operative planning. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Selective isolation and noninvasive analysis of circulating cancer stem cells through Raman imaging.

    Science.gov (United States)

    Cho, Hyeon-Yeol; Hossain, Md Khaled; Lee, Jin-Ho; Han, Jiyou; Lee, Hun Joo; Kim, Kyeong-Jun; Kim, Jong-Hoon; Lee, Ki-Bum; Choi, Jeong-Woo

    2018-04-15

    Circulating cancer stem cells (CCSCs), a rare circulating tumor cell (CTC) type, recently arose as a useful resource for monitoring and characterizing both cancers and their metastatic derivatives. However, due to the scarcity of CCSCs among hematologic cells in the blood and the complexity of the phenotype confirmation process, CCSC research can be extremely challenging. Hence, we report a nanoparticle-mediated Raman imaging method for CCSC characterization which profiles CCSCs based on their surface marker expression phenotypes. We have developed an integrated combinatorial Raman-Active Nanoprobe (RAN) system combined with a microfluidic chip to successfully process complete blood samples. CCSCs and CTCs were detected (90% efficiency) and classified in accordance with their respective surface marker expression via completely distinct Raman signals of RANs. Selectively isolated CCSCs (93% accuracy) were employed for both in vitro and in vivo tumor phenotyping to identify the tumorigenicity of the CCSCs. We utilized our new method to predict metastasis by screening blood samples from xenograft models, showing that upon CCSC detection, all subjects exhibited liver metastasis. Having highly efficient detection and noninvasive isolation capabilities, we have demonstrated that our RAN-based Raman imaging method will be valuable for predicting cancer metastasis and relapse via CCSC detection. Moreover, the exclusion of peak overlapping in CCSC analysis with our Raman imaging method will allow to expand the RAN families for various cancer types, therefore, increasing therapeutic efficacy by providing detailed molecular features of tumor subtypes. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. COLOR IMAGES

    Directory of Open Access Journals (Sweden)

    Dominique Lafon

    2011-05-01

    Full Text Available The goal of this article is to present specific capabilities and limitations of the use of color digital images in a characterization process. The whole process is investigated, from the acquisition of digital color images to the analysis of the information relevant to various applications in the field of material characterization. A digital color image can be considered as a matrix of pixels with values expressed in a vector-space (commonly 3 dimensional space whose specificity, compared to grey-scale images, is to ensure a coding and a representation of the output image (visualisation printing that fits the human visual reality. In a characterization process, it is interesting to regard color image attnbutes as a set of visual aspect measurements on a material surface. Color measurement systems (spectrocolorimeters, colorimeters and radiometers and cameras use the same type of light detectors: most of them use Charge Coupled Devices sensors. The difference between the two types of color data acquisition systems is that color measurement systems provide a global information of the observed surface (average aspect of the surface: the color texture is not taken into account. Thus, it seems interesting to use imaging systems as measuring instruments for the quantitative characterization of the color texture.

  9. Magnetic motion capture system using LC resonant magnetic marker composed of Ni-Zn ferrite core

    International Nuclear Information System (INIS)

    Hashi, S.; Toyoda, M.; Ohya, M.; Okazaki, Y.; Yabukami, S.; Ishiyama, K.; Arai, K. I.

    2006-01-01

    We have proposed a magnetic motion capture system using an LC resonant magnetic marker. The proposed system is composed of an exciting coil, an LC marker, and a 5x5-matrix search coil array (25 search coils). The LC marker is small and has a minimal circuit with no battery and can be driven wirelessly by the action of electromagnetic induction. It consists of a Ni-Zn ferrite core (3 mmφx10 mm) with a wound coil and a chip capacitor, forming an LC series circuit with a resonant frequency of 186 kHz. The relative position accuracy of the system is less than 1 mm within the area of 100 mm 3 up to 150 mm from the search coil array. Compared with dc magnetic systems, the proposed system is applicable for precision motion capture in optically isolated spaces without magnetic shielding because the system is not greatly influenced by earth field noise

  10. Improved Interactive Medical-Imaging System

    Science.gov (United States)

    Ross, Muriel D.; Twombly, Ian A.; Senger, Steven

    2003-01-01

    An improved computational-simulation system for interactive medical imaging has been invented. The system displays high-resolution, three-dimensional-appearing images of anatomical objects based on data acquired by such techniques as computed tomography (CT) and magnetic-resonance imaging (MRI). The system enables users to manipulate the data to obtain a variety of views for example, to display cross sections in specified planes or to rotate images about specified axes. Relative to prior such systems, this system offers enhanced capabilities for synthesizing images of surgical cuts and for collaboration by users at multiple, remote computing sites.

  11. Soft x-ray imaging system for measurement of noncircular tokamak plasmas

    International Nuclear Information System (INIS)

    Fonck, R.J.; Reusch, M.; Jaehnig, K.P.; Hulse, R.; Roney, P.

    1986-08-01

    A soft x-ray camera and image processing system has been constructed to provide measurements of the internal shape of high temperature tokamak plasmas. The camera consists of a metallic-foil-filtered pinhole aperture and a microchannel plate image intensifier/convertor which produces a visible image for detection by a CCD TV camera. A wide-angle tangential view of the toroidal plasma allows a single compact camera to view the entire plasma cross section. With Be filters 12 to 50 μm thick, the signal from the microchannel plate is produced mostly by nickel L-line emissions which orignate in the hot plasma core. The measured toroidal image is numerically inverted to produce a cross-sectional soft x-ray image of the plasma. Since the internal magnetic flux surfaces are usually isothermal and the nickel emissivity depends strongly on the local electron temperature, the x-ray emission contours reflect the shape of the magnetic surfaces in the plasma interior. Initial results from the PBX tokamak experiment show clear differences in internal plasma shapes for circular and bean-shaped discharges

  12. Applying a CAD-generated imaging marker to assess short-term breast cancer risk

    Science.gov (United States)

    Mirniaharikandehei, Seyedehnafiseh; Zarafshani, Ali; Heidari, Morteza; Wang, Yunzhi; Aghaei, Faranak; Zheng, Bin

    2018-02-01

    Although whether using computer-aided detection (CAD) helps improve radiologists' performance in reading and interpreting mammograms is controversy due to higher false-positive detection rates, objective of this study is to investigate and test a new hypothesis that CAD-generated false-positives, in particular, the bilateral summation of false-positives, is a potential imaging marker associated with short-term breast cancer risk. An image dataset involving negative screening mammograms acquired from 1,044 women was retrospectively assembled. Each case involves 4 images of craniocaudal (CC) and mediolateral oblique (MLO) view of the left and right breasts. In the next subsequent mammography screening, 402 cases were positive for cancer detected and 642 remained negative. A CAD scheme was applied to process all "prior" negative mammograms. Some features from CAD scheme were extracted, which include detection seeds, the total number of false-positive regions, an average of detection scores and the sum of detection scores in CC and MLO view images. Then the features computed from two bilateral images of left and right breasts from either CC or MLO view were combined. In order to predict the likelihood of each testing case being positive in the next subsequent screening, two logistic regression models were trained and tested using a leave-one-case-out based cross-validation method. Data analysis demonstrated the maximum prediction accuracy with an area under a ROC curve of AUC=0.65+/-0.017 and the maximum adjusted odds ratio of 4.49 with a 95% confidence interval of [2.95, 6.83]. The results also illustrated an increasing trend in the adjusted odds ratio and risk prediction scores (pbreast cancer risk.

  13. Detection of cracks on concrete surfaces by hyperspectral image processing

    Science.gov (United States)

    Santos, Bruno O.; Valença, Jonatas; Júlio, Eduardo

    2017-06-01

    All large infrastructures worldwide must have a suitable monitoring and maintenance plan, aiming to evaluate their behaviour and predict timely interventions. In the particular case of concrete infrastructures, the detection and characterization of crack patterns is a major indicator of their structural response. In this scope, methods based on image processing have been applied and presented. Usually, methods focus on image binarization followed by applications of mathematical morphology to identify cracks on concrete surface. In most cases, publications are focused on restricted areas of concrete surfaces and in a single crack. On-site, the methods and algorithms have to deal with several factors that interfere with the results, namely dirt and biological colonization. Thus, the automation of a procedure for on-site characterization of crack patterns is of great interest. This advance may result in an effective tool to support maintenance strategies and interventions planning. This paper presents a research based on the analysis and processing of hyper-spectral images for detection and classification of cracks on concrete structures. The objective of the study is to evaluate the applicability of several wavelengths of the electromagnetic spectrum for classification of cracks in concrete surfaces. An image survey considering highly discretized wavelengths between 425 nm and 950 nm was performed on concrete specimens, with bandwidths of 25 nm. The concrete specimens were produced with a crack pattern induced by applying a load with displacement control. The tests were conducted to simulate usual on-site drawbacks. In this context, the surface of the specimen was subjected to biological colonization (leaves and moss). To evaluate the results and enhance crack patterns a clustering method, namely k-means algorithm, is being applied. The research conducted allows to define the suitability of using clustering k-means algorithm combined with hyper-spectral images highly

  14. Development of an image processing system in splendid squid quality classification

    Science.gov (United States)

    Masunee, Niyada; Chaiprapat, Supapan; Waiyagan, Kriangkrai

    2013-07-01

    Agricultural products typically exhibit high variance in quality characteristics. To assure customer satisfaction and control manufacturing productivity, quality classification is necessary to screen off defective items and to grade the products. This article presents an application of image processing techniques on squid grading and defect discrimination. A preliminary study indicated that surface color was an efficient determinant to justify quality of splendid squids. In this study, a computer vision system (CVS) was developed to examine the characteristics of splendid squids. Using image processing techniques, squids could be classified into three different quality grades as in accordance with an industry standard. The developed system first sifted through squid images to reject ones with black marks. Qualified squids were graded on a proportion of white, pink, and red regions appearing on their bodies by using fuzzy logic. The system was evaluated on 100 images of squids at different quality levels. It was found that accuracy obtained by the proposed technique was 95% compared with sensory evaluation of an expert.

  15. SU-G-BRA-05: Application of a Feature-Based Tracking Algorithm to KV X-Ray Fluoroscopic Images Toward Marker-Less Real-Time Tumor Tracking

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, M; Matsuo, Y; Mukumoto, N; Iizuka, Y; Yokota, K; Mizowaki, T; Hiraoka, M [Kyoto University, Graduate School of Medicine, Kyoto (Japan); Nakao, M [Kyoto University, Graduate School of Informatics, Kyoto (Japan)

    2016-06-15

    Purpose: To detect target position on kV X-ray fluoroscopic images using a feature-based tracking algorithm, Accelerated-KAZE (AKAZE), for markerless real-time tumor tracking (RTTT). Methods: Twelve lung cancer patients treated with RTTT on the Vero4DRT (Mitsubishi Heavy Industries, Japan, and Brainlab AG, Feldkirchen, Germany) were enrolled in this study. Respiratory tumor movement was greater than 10 mm. Three to five fiducial markers were implanted around the lung tumor transbronchially for each patient. Before beam delivery, external infrared (IR) markers and the fiducial markers were monitored for 20 to 40 s with the IR camera every 16.7 ms and with an orthogonal kV x-ray imaging subsystem every 80 or 160 ms, respectively. Target positions derived from the fiducial markers were determined on the orthogonal kV x-ray images, which were used as the ground truth in this study. Meanwhile, tracking positions were identified by AKAZE. Among a lot of feature points, AKAZE found high-quality feature points through sequential cross-check and distance-check between two consecutive images. Then, these 2D positional data were converted to the 3D positional data by a transformation matrix with a predefined calibration parameter. Root mean square error (RMSE) was calculated to evaluate the difference between 3D tracking and target positions. A total of 393 frames was analyzed. The experiment was conducted on a personal computer with 16 GB RAM, Intel Core i7-2600, 3.4 GHz processor. Results: Reproducibility of the target position during the same respiratory phase was 0.6 +/− 0.6 mm (range, 0.1–3.3 mm). Mean +/− SD of the RMSEs was 0.3 +/− 0.2 mm (range, 0.0–1.0 mm). Median computation time per frame was 179 msec (range, 154–247 msec). Conclusion: AKAZE successfully and quickly detected the target position on kV X-ray fluoroscopic images. Initial results indicate that the differences between 3D tracking and target position would be clinically acceptable.

  16. SU-G-BRA-05: Application of a Feature-Based Tracking Algorithm to KV X-Ray Fluoroscopic Images Toward Marker-Less Real-Time Tumor Tracking

    International Nuclear Information System (INIS)

    Nakamura, M; Matsuo, Y; Mukumoto, N; Iizuka, Y; Yokota, K; Mizowaki, T; Hiraoka, M; Nakao, M

    2016-01-01

    Purpose: To detect target position on kV X-ray fluoroscopic images using a feature-based tracking algorithm, Accelerated-KAZE (AKAZE), for markerless real-time tumor tracking (RTTT). Methods: Twelve lung cancer patients treated with RTTT on the Vero4DRT (Mitsubishi Heavy Industries, Japan, and Brainlab AG, Feldkirchen, Germany) were enrolled in this study. Respiratory tumor movement was greater than 10 mm. Three to five fiducial markers were implanted around the lung tumor transbronchially for each patient. Before beam delivery, external infrared (IR) markers and the fiducial markers were monitored for 20 to 40 s with the IR camera every 16.7 ms and with an orthogonal kV x-ray imaging subsystem every 80 or 160 ms, respectively. Target positions derived from the fiducial markers were determined on the orthogonal kV x-ray images, which were used as the ground truth in this study. Meanwhile, tracking positions were identified by AKAZE. Among a lot of feature points, AKAZE found high-quality feature points through sequential cross-check and distance-check between two consecutive images. Then, these 2D positional data were converted to the 3D positional data by a transformation matrix with a predefined calibration parameter. Root mean square error (RMSE) was calculated to evaluate the difference between 3D tracking and target positions. A total of 393 frames was analyzed. The experiment was conducted on a personal computer with 16 GB RAM, Intel Core i7-2600, 3.4 GHz processor. Results: Reproducibility of the target position during the same respiratory phase was 0.6 +/− 0.6 mm (range, 0.1–3.3 mm). Mean +/− SD of the RMSEs was 0.3 +/− 0.2 mm (range, 0.0–1.0 mm). Median computation time per frame was 179 msec (range, 154–247 msec). Conclusion: AKAZE successfully and quickly detected the target position on kV X-ray fluoroscopic images. Initial results indicate that the differences between 3D tracking and target position would be clinically acceptable.

  17. 3D spectrum imaging of multi-wall carbon nanotube coupled π-surface modes utilising electron energy-loss spectra acquired using a STEM/Enfina system

    International Nuclear Information System (INIS)

    Seepujak, A.; Bangert, U.; Gutierrez-Sosa, A.; Harvey, A.J.; Blank, V.D.; Kulnitskiy, B.A.; Batov, D.V.

    2005-01-01

    Numerous studies have utilised electron energy-loss (EEL) spectra acquired in the plasmon (2-10 eV) regime in order to probe delocalised π-electronic states of multi-wall carbon nanotubes (MWCNTs). Interpretation of electron energy loss (EEL) spectra of MWCNTs in the 2-10 eV regime. Carbon (accepted for publication); Blank et al. J. Appl. Phys. 91 (2002) 1657). In the present contribution, EEL spectra were acquired from a 2D raster defined on a bottle-shaped MWCNT, using a Gatan UHV Enfina system attached to a dedicated scanning transmission electron microscope (STEM). The technique utilised to isolate and sequentially filter each of the volume and surface resonances is described in detail. Utilising a scale for the intensity of a filtered mode enables one to 'see' the distribution of each resonance in the raster. This enables striking 3D resonance-filtered spectrum images (SIs) of π-collective modes to be observed. Red-shift of the lower energy split π-surface resonance provides explicit evidence of π-surface mode coupling predicted for thin graphitic films (Lucas et al. Phys. Rev. B 49 (1994) 2888). Resonance-filtered SIs are also compared to non-filtered SIs with suppressed surface contributions, acquired utilising a displaced collector aperture. The present filtering technique is seen to isolate surface contributions more effectively, and without the significant loss of statistics, associated with the displaced collector aperture mode. Isolation of collective modes utilising 3D resonance-filtered spectrum imaging, demonstrates a valuable method for 'pinpointing' the location of discrete modes in irregularly shaped nanostructures

  18. Advancements in medium and high resolution Earth observation for land-surface imaging: Evolutions, future trends and contributions to sustainable development

    Science.gov (United States)

    Ouma, Yashon O.

    2016-01-01

    Technologies for imaging the surface of the Earth, through satellite based Earth observations (EO) have enormously evolved over the past 50 years. The trends are likely to evolve further as the user community increases and their awareness and demands for EO data also increases. In this review paper, a development trend on EO imaging systems is presented with the objective of deriving the evolving patterns for the EO user community. From the review and analysis of medium-to-high resolution EO-based land-surface sensor missions, it is observed that there is a predictive pattern in the EO evolution trends such that every 10-15 years, more sophisticated EO imaging systems with application specific capabilities are seen to emerge. Such new systems, as determined in this review, are likely to comprise of agile and small payload-mass EO land surface imaging satellites with the ability for high velocity data transmission and huge volumes of spatial, spectral, temporal and radiometric resolution data. This availability of data will magnify the phenomenon of ;Big Data; in Earth observation. Because of the ;Big Data; issue, new computing and processing platforms such as telegeoprocessing and grid-computing are expected to be incorporated in EO data processing and distribution networks. In general, it is observed that the demand for EO is growing exponentially as the application and cost-benefits are being recognized in support of resource management.

  19. Visual tracking for multi-modality computer-assisted image guidance

    Science.gov (United States)

    Basafa, Ehsan; Foroughi, Pezhman; Hossbach, Martin; Bhanushali, Jasmine; Stolka, Philipp

    2017-03-01

    With optical cameras, many interventional navigation tasks previously relying on EM, optical, or mechanical guidance can be performed robustly, quickly, and conveniently. We developed a family of novel guidance systems based on wide-spectrum cameras and vision algorithms for real-time tracking of interventional instruments and multi-modality markers. These navigation systems support the localization of anatomical targets, support placement of imaging probe and instruments, and provide fusion imaging. The unique architecture - low-cost, miniature, in-hand stereo vision cameras fitted directly to imaging probes - allows for an intuitive workflow that fits a wide variety of specialties such as anesthesiology, interventional radiology, interventional oncology, emergency medicine, urology, and others, many of which see increasing pressure to utilize medical imaging and especially ultrasound, but have yet to develop the requisite skills for reliable success. We developed a modular system, consisting of hardware (the Optical Head containing the mini cameras) and software (components for visual instrument tracking with or without specialized visual features, fully automated marker segmentation from a variety of 3D imaging modalities, visual observation of meshes of widely separated markers, instant automatic registration, and target tracking and guidance on real-time multi-modality fusion views). From these components, we implemented a family of distinct clinical and pre-clinical systems (for combinations of ultrasound, CT, CBCT, and MRI), most of which have international regulatory clearance for clinical use. We present technical and clinical results on phantoms, ex- and in-vivo animals, and patients.

  20. Laser electro-optic system for rapid three-dimensional /3-D/ topographic mapping of surfaces

    Science.gov (United States)

    Altschuler, M. D.; Altschuler, B. R.; Taboada, J.

    1981-01-01

    It is pointed out that the generic utility of a robot in a factory/assembly environment could be substantially enhanced by providing a vision capability to the robot. A standard videocamera for robot vision provides a two-dimensional image which contains insufficient information for a detailed three-dimensional reconstruction of an object. Approaches which supply the additional information needed for the three-dimensional mapping of objects with complex surface shapes are briefly considered and a description is presented of a laser-based system which can provide three-dimensional vision to a robot. The system consists of a laser beam array generator, an optical image recorder, and software for controlling the required operations. The projection of a laser beam array onto a surface produces a dot pattern image which is viewed from one or more suitable perspectives. Attention is given to the mathematical method employed, the space coding technique, the approaches used for obtaining the transformation parameters, the optics for laser beam array generation, the hardware for beam array coding, and aspects of image acquisition.

  1. Advances in Surface Plasmon Resonance Imaging enable quantitative measurement of laterally heterogeneous coatings of nanoscale thickness

    Science.gov (United States)

    Raegen, Adam; Reiter, Kyle; Clarke, Anthony; Lipkowski, Jacek; Dutcher, John

    2013-03-01

    The Surface Plasmon Resonance (SPR) phenomenon is routinely exploited to qualitatively probe changes to the optical properties of nanoscale coatings on thin metallic surfaces, for use in probes and sensors. Unfortunately, extracting truly quantitative information is usually limited to a select few cases - uniform absorption/desorption of small biomolecules and films, in which a continuous ``slab'' model is a good approximation. We present advancements in the SPR technique that expand the number of cases for which the technique can provide meaningful results. Use of a custom, angle-scanning SPR imaging system, together with a refined data analysis method, allow for quantitative kinetic measurements of laterally heterogeneous systems. We first demonstrate the directionally heterogeneous nature of the SPR phenomenon using a directionally ordered sample, then show how this allows for the calculation of the average coverage of a heterogeneous sample. Finally, the degradation of cellulose microfibrils and bundles of microfibrils due to the action of cellulolytic enzymes will be presented as an excellent example of the capabilities of the SPR imaging system.

  2. Remote radiation imaging system using a compact gamma-ray imager mounted on a multicopter drone

    International Nuclear Information System (INIS)

    Sato, Yuki; Terasaka, Yuta; Kaburagi, Masaaki; Tanifuji, Yuta; Kawabata, Kuniaki; Miyamura, Hiroko; Torii, Tatsuo; Ozawa, Shingo; Izumi, Ryo; Suzuki, Toshikazu

    2018-01-01

    A remote radiation imaging system comprising a lightweight Compton camera and a multicopter drone was developed to remotely and quickly measure radioactive contamination inside the buildings of the Fukushima Daiichi Nuclear Power Station (FDNPS). The drone system is used for measuring detailed radiation distributions in narrow areas, which have been difficult to gauge with conventional aircraft monitoring using helicopters. A measurement of radiation distributions in outdoor environments in the coastal areas of Fukushima, Japan, was performed. The drone system with the Compton camera succeeded in remote observations of dense hotspots from the sky over a contaminated area near the FDNPS. The time required for image reconstruction is approximately 550 s in the case of a 9-m flight altitude for the hotspots with a surface dose rate of several tens of μSv/h. This drone system will be used inside the buildings of the FDNPS for remote measurement of radioactive contamination. (author)

  3. Online patient dosimetry and an image quality audit system in digital radiology

    International Nuclear Information System (INIS)

    Fernandez, J. M.; Vano, E.; Ten, J. I.; Prieto, C.; Martinez, D.

    2006-01-01

    The present work describes an online patient dosimetry and an image quality audit system in digital radiology. the system allows auditing of different parameters depending on contents of DICOM (Digital Imaging and Communication in Medicine) header. For the patient dosimetry audit, current mean values of entrance surface dose (ESD) were compared with local and national reference values (RVs) for the specific examination type evaluated. Mean values exceeding the RV trigger an alarm signal and then an evaluation of the technical parameters, operational practice and image quality starts, using data available in the DICOM header to derive any abnormal settings or performance to obtain the image. the X-ray tube output for different kVp values is measured periodically, allowing for the automatic calculation of the ESD. The system also allows for image quality audit linking it with the dose imparted and other technical parameters if the alarm condition if produced. Results and advantages derived from this online quality control are discussed. (Author) 5 refs

  4. SU-F-J-21: Clinical Evaluation of Surface Scanning Systems in Different Treatment Locations

    Energy Technology Data Exchange (ETDEWEB)

    Moser, T; Karger, C [German Cancer Research Center (DKFZ), Heidelberg (Germany); Stefanowicz, S; Rhein, B; Oetzel, D; Adeberg, S; Koenig, L; Wolf, R; Rieken, S [Heidelberg University, Heidelberg (Germany)

    2016-06-15

    Purpose: To reduce imaging dose in fractionated IGRT, the ability of optical surface imaging systems (OSIS) to detect setup errors was tested. Therefore, clinical studies to evaluate for different treatment locations setup corrections derived by OSIS in comparison with x-ray image guidance in fractionated radiation therapy was performed. Methods: The setup correction accuracy of an OSIS system (AlignRT, VisionRT, London, UK) will be analysed for the 4 tumour locations Pelvis, Upper Abdomen, Thorax and Breast, 20 patients for each location in comparison to a different system (Sentinel, C-RAD, SE). For each patient, the setup corrections of the cone-beam computed tomography (CBCT) of an Elekta Versa HD linear accelerator (Elekta, Crawley, UK) is considered as gold-standard and then compared with those of the OSIS for the first ten fractions retrospectively. There were no clinical decisions made based on the surrogate system. For the OSIS, the reference surface is highly important as it represents the actual ground truth. It can be obtained either with the system itself or the surface structure delineated in the planning CT can be imported via DICOM interface. In this paper, the first results for the treatment region thorax are presented. The reference image modalities were compared. Results: Table 1 displays the difference between the setup corrections obtained with OSIS and CBCT in lateral (LAT), longitudinal (LNG) and vertical (VRT) direction for the DICOM reference image. While the median deviations are within a few millimeters, some outliers showed large deviations. Generally, the mean deviation as well as the spread was smallest in lateral and largest in vertical direction. Conclusion: Although the system allows fast, simple and non-invasive determination of setup corrections, it should be evaluated treatment region dependant. Therefore, the study is ongoing. The application of OSIS may help to reduce the imaging dose for the patient. We gratefully acknowledge

  5. Stemness-related markers in cancer

    Directory of Open Access Journals (Sweden)

    Wenxiu Zhao

    2017-01-01

    Full Text Available Cancer stem cells (CSCs, with their self-renewal ability and multilineage differentiation potential, are a critical subpopulation of tumor cells that can drive tumor initiation, growth, and resistance to therapy. Like embryonic and adult stem cells, CSCs express markers that are not expressed in normal somatic cells and are thus thought to contribute toward a “stemness” phenotype. This review summarizes the current knowledge of stemness-related markers in human cancers, with a particular focus on important transcription factors, protein surface markers, and signaling pathways.

  6. METHOD FOR CREATION OF SPHERICAL PANORAMAS FROM IMAGES OBTAINED BY OMNIDIRECTIONAL OPTOELECTRONIC SYSTEMS

    Directory of Open Access Journals (Sweden)

    V. P. Lazarenko

    2016-01-01

    Full Text Available Subject of Study. The key feature of spherical panoramas is the maximum possible angle of view (360 × 180 degrees. Omnidirectional optical-electronic systems are able to produce images that show most of this space, but these images are different from the canonical spherical panoramas. This paper proposes a method of converting the circular images obtained by omnidirectional optical systems, to canonical spherical panoramic images with the use ofcalibration procedure of omnidirectional optical-electronic system. Method. The process of spherical panoramas creation consists of three steps.The first step includesthe forming of virtual surface in the object space corresponding to a field of view of the spherical panorama. The surface is defined by the three-dimensional array of pixels.At the second step the coordinates of images of these points in the plane of the detectorare specified. At the third step pixel-by-pixel forming of the output imageisperformed from the original omnidirectional image with the use of coordinates obtained at the second step. Main Results. We have considered the geometric projectionmodel of spherical panoramas. The algorithm has been proposed calculating the three-dimensional array of pixels, characterizing the field of view of a spherical panorama and convenient for practical usage. The developed method is designed to work with omnidirectional optical-electronic systems both with catadioptric optical systems and with fisheye lens. Experimental results confirming the validity of this method are presented. The reprojection mean-square error was equal to 0.794 px. Practical Relevance. The proposed method can be applied in technologies of creating of virtual tours or panoramas of streets where spherical panoramic images are the standard for storing visual information. The method may also find its application in various fields of robotics, orientation and navigation of space vehicles and UAVs.

  7. Markers of T Cell Senescence in Humans

    Directory of Open Access Journals (Sweden)

    Weili Xu

    2017-08-01

    Full Text Available Many countries are facing the aging of their population, and many more will face a similar obstacle in the near future, which could be a burden to many healthcare systems. Increased susceptibility to infections, cardiovascular and neurodegenerative disease, cancer as well as reduced efficacy of vaccination are important matters for researchers in the field of aging. As older adults show higher prevalence for a variety of diseases, this also implies higher risk of complications, including nosocomial infections, slower recovery and sequels that may reduce the autonomy and overall quality of life of older adults. The age-related effects on the immune system termed as “immunosenescence” can be exemplified by the reported hypo-responsiveness to influenza vaccination of the elderly. T cells, which belong to the adaptive arm of the immune system, have been extensively studied and the knowledge gathered enables a better understanding of how the immune system may be affected after acute/chronic infections and how this matters in the long run. In this review, we will focus on T cells and discuss the surface and molecular markers that are associated with T cell senescence. We will also look at the implications that senescent T cells could have on human health and diseases. Finally, we will discuss the benefits of having these markers for investigators and the future work that is needed to advance the field of T cell senescence markers.

  8. Image Analysis Technique for Material Behavior Evaluation in Civil Structures

    Science.gov (United States)

    Moretti, Michele; Rossi, Gianluca

    2017-01-01

    The article presents a hybrid monitoring technique for the measurement of the deformation field. The goal is to obtain information about crack propagation in existing structures, for the purpose of monitoring their state of health. The measurement technique is based on the capture and analysis of a digital image set. Special markers were used on the surface of the structures that can be removed without damaging existing structures as the historical masonry. The digital image analysis was done using software specifically designed in Matlab to follow the tracking of the markers and determine the evolution of the deformation state. The method can be used in any type of structure but is particularly suitable when it is necessary not to damage the surface of structures. A series of experiments carried out on masonry walls of the Oliverian Museum (Pesaro, Italy) and Palazzo Silvi (Perugia, Italy) have allowed the validation of the procedure elaborated by comparing the results with those derived from traditional measuring techniques. PMID:28773129

  9. Artificial frame filling using adaptive neural fuzzy inference system for particle image velocimetry dataset

    Science.gov (United States)

    Akdemir, Bayram; Doǧan, Sercan; Aksoy, Muharrem H.; Canli, Eyüp; Özgören, Muammer

    2015-03-01

    Liquid behaviors are very important for many areas especially for Mechanical Engineering. Fast camera is a way to observe and search the liquid behaviors. Camera traces the dust or colored markers travelling in the liquid and takes many pictures in a second as possible as. Every image has large data structure due to resolution. For fast liquid velocity, there is not easy to evaluate or make a fluent frame after the taken images. Artificial intelligence has much popularity in science to solve the nonlinear problems. Adaptive neural fuzzy inference system is a common artificial intelligence in literature. Any particle velocity in a liquid has two dimension speed and its derivatives. Adaptive Neural Fuzzy Inference System has been used to create an artificial frame between previous and post frames as offline. Adaptive neural fuzzy inference system uses velocities and vorticities to create a crossing point vector between previous and post points. In this study, Adaptive Neural Fuzzy Inference System has been used to fill virtual frames among the real frames in order to improve image continuity. So this evaluation makes the images much understandable at chaotic or vorticity points. After executed adaptive neural fuzzy inference system, the image dataset increase two times and has a sequence as virtual and real, respectively. The obtained success is evaluated using R2 testing and mean squared error. R2 testing has a statistical importance about similarity and 0.82, 0.81, 0.85 and 0.8 were obtained for velocities and derivatives, respectively.

  10. MULTIPLE IMAGING TECHNIQUES DEMONSTRATE THE MANIPULATION OF SURFACES TO REDUCE BACTERIAL CONTAMINATION

    Science.gov (United States)

    Surface imaging techniques were combined to determine appropriate manipulation of technologically important surfaces for commercial applications. Stainless steel surfaces were engineered to reduce bacterial contamination, biofilm formation, and corrosion during product processing...

  11. SERS imaging of cell-surface biomolecules metabolically labeled with bioorthogonal Raman reporters.

    Science.gov (United States)

    Xiao, Ming; Lin, Liang; Li, Zefan; Liu, Jie; Hong, Senlian; Li, Yaya; Zheng, Meiling; Duan, Xuanming; Chen, Xing

    2014-08-01

    Live imaging of biomolecules with high specificity and sensitivity as well as minimal perturbation is essential for studying cellular processes. Here, we report the development of a bioorthogonal surface-enhanced Raman scattering (SERS) imaging approach that exploits small Raman reporters for visualizing cell-surface biomolecules. The cells were cultured and imaged by SERS microscopy on arrays of Raman-enhancing nanoparticles coated on silicon wafers or glass slides. The Raman reporters including azides, alkynes, and carbondeuterium bonds are small in size and spectroscopically bioorthogonal (background-free). We demonstrated that various cell-surface biomolecules including proteins, glycans, and lipids were metabolically incorporated with the corresponding precursors bearing a Raman reporter and visualized by SERS microscopy. The coupling of SERS microscopy with bioorthogonal Raman reporters expands the capabilities of live-cell microscopy beyond the modalities of fluorescence and label-free imaging. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. A prototype tap test imaging system: Initial field test results

    Science.gov (United States)

    Peters, J. J.; Barnard, D. J.; Hudelson, N. A.; Simpson, T. S.; Hsu, D. K.

    2000-05-01

    This paper describes a simple, field-worthy tap test imaging system that gives quantitative information about the size, shape, and severity of defects and damages. The system consists of an accelerometer, electronic circuits for conditioning the signal and measuring the impact duration, a laptop PC and data acquisition and processing software. The images are generated manually by tapping on a grid printed on a plastic sheet laid over the part's surface. A mechanized scanner is currently under development. The prototype has produced images for a variety of aircraft composite and metal honeycomb structures containing flaws, damages, and repairs. Images of the local contact stiffness, deduced from the impact duration using a spring model, revealed quantitatively the stiffness reduction due to flaws and damages, as well as the stiffness enhancement due to substructures. The system has been field tested on commercial and military aircraft as well as rotor blades and engine decks on helicopters. Field test results will be shown and the operation of the system will be demonstrated.—This material is based upon work supported by the Federal Aviation Administration under Contract #DTFA03-98-D-00008, Delivery Order No. IA016 and performed at Iowa State University's Center for NDE as part of the Center for Aviation Systems Reliability program.

  13. Surface topography characterization using 3D stereoscopic reconstruction of SEM images

    Science.gov (United States)

    Vedantha Krishna, Amogh; Flys, Olena; Reddy, Vijeth V.; Rosén, B. G.

    2018-06-01

    A major drawback of the optical microscope is its limitation to resolve finer details. Many microscopes have been developed to overcome the limitations set by the diffraction of visible light. The scanning electron microscope (SEM) is one such alternative: it uses electrons for imaging, which have much smaller wavelength than photons. As a result high magnification with superior image resolution can be achieved. However, SEM generates 2D images which provide limited data for surface measurements and analysis. Often many research areas require the knowledge of 3D structures as they contribute to a comprehensive understanding of microstructure by allowing effective measurements and qualitative visualization of the samples under study. For this reason, stereo photogrammetry technique is employed to convert SEM images into 3D measurable data. This paper aims to utilize a stereoscopic reconstruction technique as a reliable method for characterization of surface topography. Reconstructed results from SEM images are compared with coherence scanning interferometer (CSI) results obtained by measuring a roughness reference standard sample. This paper presents a method to select the most robust/consistent surface texture parameters that are insensitive to the uncertainties involved in the reconstruction technique itself. Results from the two-stereoscopic reconstruction algorithms are also documented in this paper.

  14. Systems and methods for imaging using radiation from laser produced plasmas

    Science.gov (United States)

    Renard-Le Galloudec, Nathalie; Cowan, Thomas E.; Sentoku, Yasuhiko; Rassuchine, Jennifer

    2009-06-30

    In particular embodiments, the present disclosure provides systems and methods for imaging a subject using radiation emitted from a laser produced plasma generating by irradiating a target with a laser. In particular examples, the target includes at least one radiation enhancing component, such as a fluor, cap, or wire. In further examples, the target has a metal layer and an internal surface defining an internal apex, the internal apex of less than about 15 .mu.m, such as less than about 1 .mu.m. The targets may take a variety of shapes, including cones, pyramids, and hemispheres. Certain aspects of the present disclosure provide improved imaging of a subject, such as improved medical images of a radiation dose than typical conventional methods and systems.

  15. Metal-Based Systems for Molecular Imaging Applications - COST D38 Annual Workshop - Scientific Program and Abstracts

    International Nuclear Information System (INIS)

    Mikolajczak, R.

    2009-01-01

    The main objective of the Action is the development of metal-based imaging probes for cellular and molecular imaging applications, based on MRI, PET, SPECT and optical imaging that will facilitate early diagnosis, assessment of disease progression and treatment evaluation.The goal of this Action is to further the development of innovative imaging probes through the pursuit of innovations in a number of different areas, ranging from the design of imaging units endowed with enhanced sensitivity to the control of the structural and electronic determinants responsible for the molecular recognition of the target molecule.At present, in vivo diagnostic systems basically assess the structure and function of human organs. Therefore, for important diseases such as cancer and cardiovascular pathologies,and also diseases of the central nervous system, only the late symptoms are detected. It is expected that the advances in genomics and proteomics will have a tremendous impact on human health care of the future. However, advances in molecular biology are already redefining diseases in terms of molecular abnormalities. With this knowledge, new generations of diagnostic imaging agents can be defined that aim at the detection of those molecular processes in vivo.The molecular imaging approach offers a great potential for earlier detection and characterisation of disease, and evaluation of treatment. However, more research is necessary to bring these ideas to clinical applications and a key aspect relates to the development of high-specificity, high-sensitivity imaging probes for the different detection modalities. Additionally, the Action includes research activities dealing with the exploitation of peculiar nuclear properties of given isotopes for therapeutic effects, thus integrating the diagnostic and the therapeutic stages.Apart from its use in early diagnosis in clinical practice, the molecular imaging approach will have also a major impact on the development of new

  16. CRISPR Primer Designer: Design primers for knockout and chromosome imaging CRISPR-Cas system.

    Science.gov (United States)

    Yan, Meng; Zhou, Shi-Rong; Xue, Hong-Wei

    2015-07-01

    The clustered regularly interspaced short palindromic repeats (CRISPR)-associated system enables biologists to edit genomes precisely and provides a powerful tool for perturbing endogenous gene regulation, modulation of epigenetic markers, and genome architecture. However, there are concerns about the specificity of the system, especially the usages of knocking out a gene. Previous designing tools either were mostly built-in websites or ran as command-line programs, and none of them ran locally and acquired a user-friendly interface. In addition, with the development of CRISPR-derived systems, such as chromosome imaging, there were still no tools helping users to generate specific end-user spacers. We herein present CRISPR Primer Designer for researchers to design primers for CRISPR applications. The program has a user-friendly interface, can analyze the BLAST results by using multiple parameters, score for each candidate spacer, and generate the primers when using a certain plasmid. In addition, CRISPR Primer Designer runs locally and can be used to search spacer clusters, and exports primers for the CRISPR-Cas system-based chromosome imaging system. © 2014 Institute of Botany, Chinese Academy of Sciences.

  17. A novel and compact spectral imaging system based on two curved prisms

    Science.gov (United States)

    Nie, Yunfeng; Bin, Xiangli; Zhou, Jinsong; Li, Yang

    2013-09-01

    As a novel detection approach which simultaneously acquires two-dimensional visual picture and one-dimensional spectral information, spectral imaging offers promising applications on biomedical imaging, conservation and identification of artworks, surveillance of food safety, and so forth. A novel moderate-resolution spectral imaging system consisting of merely two optical elements is illustrated in this paper. It can realize the function of a relay imaging system as well as a 10nm spectral resolution spectroscopy. Compared to conventional prismatic imaging spectrometers, this design is compact and concise with only two special curved prisms by utilizing two reflective surfaces. In contrast to spectral imagers based on diffractive grating, the usage of compound-prism possesses characteristics of higher energy utilization and wider free spectral range. The seidel aberration theory and dispersive principle of this special prism are analyzed at first. According to the results, the optical system of this design is simulated, and the performance evaluation including spot diagram, MTF and distortion, is presented. In the end, considering the difficulty and particularity of manufacture and alignment, an available method for fabrication and measurement is proposed.

  18. OSPACS: Ultrasound image management system

    Directory of Open Access Journals (Sweden)

    Bessant Conrad

    2008-06-01

    Full Text Available Abstract Background Ultrasound scanning uses the medical imaging format, DICOM, for electronically storing the images and data associated with a particular scan. Large health care facilities typically use a picture archiving and communication system (PACS for storing and retrieving such images. However, these systems are usually not suitable for managing large collections of anonymized ultrasound images gathered during a clinical screening trial. Results We have developed a system enabling the accurate archiving and management of ultrasound images gathered during a clinical screening trial. It is based upon a Windows application utilizing an open-source DICOM image viewer and a relational database. The system automates the bulk import of DICOM files from removable media by cross-validating the patient information against an external database, anonymizing the data as well as the image, and then storing the contents of the file as a field in a database record. These image records may then be retrieved from the database and presented in a tree-view control so that the user can select particular images for display in a DICOM viewer or export them to external media. Conclusion This system provides error-free automation of ultrasound image archiving and management, suitable for use in a clinical trial. An open-source project has been established to promote continued development of the system.

  19. New image-stabilizing system

    Science.gov (United States)

    Zhao, Yuejin

    1996-06-01

    In this paper, a new method for image stabilization with a three-axis image- stabilizing reflecting prism assembly is presented, and the principle of image stabilization in this prism assembly, formulae for image stabilization and working formulae with an approximation up to the third power are given in detail. In this image-stabilizing system, a single chip microcomputer is used to calculate value of compensating angles and thus to control the prism assembly. Two gyroscopes act as sensors from which information of angular perturbation is obtained, three stepping motors drive the prism assembly to compensate for the movement of image produced by angular perturbation. The image-stabilizing device so established is a multifold system which involves optics, mechanics, electronics and computer.

  20. Evaluation of Accessory Lacrimal Gland in Muller's Muscle Conjunctival Resection Specimens for Precursor Cell Markers and Biological Markers of Dry Eye Disease.

    Science.gov (United States)

    Ali, Marwan; Shah, Dhara; Pasha, Zeeshan; Jassim, Sarmad H; Jassim Jaboori, Assraa; Setabutr, Pete; Aakalu, Vinay K

    2017-04-01

    The accessory lacrimal glands (ALGs) are an understudied component of the tear functional unit, even though they are important in the development of dry eye syndrome (DES). To advance our understanding of aging changes, regenerative potential, and histologic correlates to human characteristics, we investigated human ALG tissue from surgical samples to determine the presence or absence of progenitor cell markers and lacrimal epithelial markers and to correlate marker expression to relevant patient characteristics. ALG tissues obtained from Muller's muscle conjunctival resection (MMCR) specimens were created using tissue microarrays (TMAs). Immunofluorescence staining of MMCR sections was performed using primary antibodies specific to cell protein markers. Cell marker localization in TMAs was then assessed by two blinded observers using a standardized scoring system. Patient characteristics including age, race, and status of ocular surface health were then compared against expression of stem cell markers. Human ALG expressed a number of epithelial markers, and in particular, histatin-1 was well correlated with the expression of epithelial markers and was present in most acini. In addition, we noted the presence of precursor cell markers nestin, ABCG2, and CD90 in ALG tissue. There was a decrease in precursor cell marker expression with increasing age. Finally, we noted that a negative association was present between histatin-1 expression and DES. Thus, we report for the first time that human ALG tissues contain precursor marker-positive cells and that this marker expression may decrease with increasing age. Moreover, histatin-1 expression may be decreased in DES. Future studies will be performed to use these cell markers to isolate and culture lacrimal epithelial cells from heterogeneous tissues, determine the relevance of histatin-1 expression to DES, and isolate candidate precursor cells from ALG tissue.

  1. Serum markers thrombophilia in pregnant women with Systemic Lupus Erythematosus

    Directory of Open Access Journals (Sweden)

    Vanessa Marcon de Oliveira

    Full Text Available Abstract Objectives: to determine the frequency of serum markers for hereditary and acquired thrombophilia and their association with pregnancy in women with Systemic Lupus Erythematosus (SLE. Methods: a case-control study was conducted among 25 pregnant women with SLE (study group and 32 pregnant women without known disease and with at least one previous pregnancy (control group. The presence of antiphospholipid antibodies and hereditary thrombophilia were examined in both groups. We used the y2 Test with Yates correction or Fisher's Exact Test to verify the associations and calculate the relative risk. Results: thrombophilia was present in 72.0% of pregnant women with SLE and in 6.0% of patients in the control group. A significant association was found between the presence of SLE and serum markers for hereditary thrombophilia / antiphospholipid antibodies (p<0.05. The relative risks for antiphospholipid antibodies were 13.20 (ICR95%= 1.81 - 96.46 in pregnant women with SLE, 7.26 (CI95%= 1.77 - 29.86 for the presence of serum markers of hereditary thrombophilia and 7.92 (CI95%= 2.62 - 3.94 for the presence of hereditary thrombophilia and/or antiphospholipid antibodies. Conclusions: the identification of markers for hereditary and/or acquired thrombophilia in pregnant women with lupus may be clinically useful to determine which patients have a higher risk of obstetric complications.

  2. A Novel Marker Based Method to Teeth Alignment in MRI

    Science.gov (United States)

    Luukinen, Jean-Marc; Aalto, Daniel; Malinen, Jarmo; Niikuni, Naoko; Saunavaara, Jani; Jääsaari, Päivi; Ojalammi, Antti; Parkkola, Riitta; Soukka, Tero; Happonen, Risto-Pekka

    2018-04-01

    Magnetic resonance imaging (MRI) can precisely capture the anatomy of the vocal tract. However, the crowns of teeth are not visible in standard MRI scans. In this study, a marker-based teeth alignment method is presented and evaluated. Ten patients undergoing orthognathic surgery were enrolled. Supraglottal airways were imaged preoperatively using structural MRI. MRI visible markers were developed, and they were attached to maxillary teeth and corresponding locations on the dental casts. Repeated measurements of intermarker distances in MRI and in a replica model was compared using linear regression analysis. Dental cast MRI and corresponding caliper measurements did not differ significantly. In contrast, the marker locations in vivo differed somewhat from the dental cast measurements likely due to marker placement inaccuracies. The markers were clearly visible in MRI and allowed for dental models to be aligned to head and neck MRI scans.

  3. Diagnostic markers of infection in curret pediatric practice | Chiabia ...

    African Journals Online (AJOL)

    chemokines, cytokines, adhesion molecules, cell surface markers and polymerase chain reaction are expensive and available only in specialised research laboratories. Optimal benefit can be obtained from rational use of currently available markers either by multiple marker assays or serial measurements which increase ...

  4. Delineation of cortical pathology in multiple sclerosis using multi-surface magnetization transfer ratio imaging

    Directory of Open Access Journals (Sweden)

    David A. Rudko

    2016-01-01

    Full Text Available The purpose of our study was to evaluate the utility of measurements of cortical surface magnetization transfer ratio (csMTR on the inner, mid and outer cortical boundaries as clinically accessible biomarkers of cortical gray matter pathology in multiple sclerosis (MS. Twenty-five MS patients and 12 matched controls were recruited from the MS Clinic of the Montreal Neurological Institute. Anatomical and magnetization transfer ratio (MTR images were acquired using 3 Tesla MRI at baseline and two-year time-points. MTR maps were smoothed along meshes representing the inner, mid and outer neocortical boundaries. To evaluate csMTR reductions suggestive of sub-pial demyelination in MS patients, a mixed model analysis was carried out at both the individual vertex level and in anatomically parcellated brain regions. Our results demonstrate that focal areas of csMTR reduction are most prevalent along the outer cortical surface in the superior temporal and posterior cingulate cortices, as well as in the cuneus and precentral gyrus. Additionally, age regression analysis identified that reductions of csMTR in MS patients increase with age but appear to hit a plateau in the outer caudal anterior cingulate, as well as in the precentral and postcentral cortex. After correction for the naturally occurring gradient in cortical MTR, the difference in csMTR between the inner and outer cortex in focal areas in the brains of MS patients correlated with clinical disability. Overall, our findings support multi-surface analysis of csMTR as a sensitive marker of cortical sub-pial abnormality indicative of demyelination in MS patients.

  5. Electro-optical system for the high speed reconstruction of computed tomography images

    International Nuclear Information System (INIS)

    Tresp, V.

    1989-01-01

    An electro-optical system for the high-speed reconstruction of computed tomography (CT) images has been built and studied. The system is capable of reconstructing high-contrast and high-resolution images at video rate (30 images per second), which is more than two orders of magnitude faster than the reconstruction rate achieved by special purpose digital computers used in commercial CT systems. The filtered back-projection algorithm which was implemented in the reconstruction system requires the filtering of all projections with a prescribed filter function. A space-integrating acousto-optical convolver, a surface acoustic wave filter and a digital finite-impulse response filter were used for this purpose and their performances were compared. The second part of the reconstruction, the back projection of the filtered projections, is computationally very expensive. An optical back projector has been built which maps the filtered projections onto the two-dimensional image space using an anamorphic lens system and a prism image rotator. The reconstructed image is viewed by a video camera, routed through a real-time image-enhancement system, and displayed on a TV monitor. The system reconstructs parallel-beam projection data, and in a modified version, is also capable of reconstructing fan-beam projection data. This extension is important since the latter are the kind of projection data actually acquired in high-speed X-ray CT scanners. The reconstruction system was tested by reconstructing precomputed projection data of phantom images. These were stored in a special purpose projection memory and transmitted to the reconstruction system as an electronic signal. In this way, a projection measurement system that acquires projections sequentially was simulated

  6. Diagnosis of osteoarthritis by cartilage surface smoothness quantified automatically from knee MRI

    DEFF Research Database (Denmark)

    Tummala, Sudhakar; Bay-Jensen, Anne-Christine; Karsdal, Morten A.

    2011-01-01

    Objective: We investigated whether surface smoothness of articular cartilage in the medial tibiofemoral compartment quantified from magnetic resonance imaging (MRI) could be appropriate as a diagnostic marker of osteoarthritis (OA). Method: At baseline, 159 community-based subjects aged 21 to 81...... with normal or OA-affected knees were recruited to provide a broad range of OA states. Smoothness was quantified using an automatic framework from low-field MRI in the tibial, femoral, and femoral subcompartments. Diagnostic ability of smoothness was evaluated by comparison with conventional OA markers......, correlations between smoothness and pain values and smoothness loss and cartilage loss supported a link to progression of OA. Thereby, smoothness markers may allow detection and monitoring of OA-supplemented currently accepted markers....

  7. Spin-image surface matching based target recognition in laser radar range imagery

    International Nuclear Information System (INIS)

    Li, Wang; Jian-Feng, Sun; Qi, Wang

    2010-01-01

    We explore the problem of in-plane rotation-invariance existing in the vertical detection of laser radar (Ladar) using the algorithm of spin-image surface matching. The method used to recognize the target in the range imagery of Ladar is time-consuming, owing to its complicated procedure, which violates the requirement of real-time target recognition in practical applications. To simplify the troublesome procedures, we improve the spin-image algorithm by introducing a statistical correlated coefficient into target recognition in range imagery of Ladar. The system performance is demonstrated on sixteen simulated noise range images with targets rotated through an arbitrary angle in plane. A high efficiency and an acceptable recognition rate obtained herein testify the validity of the improved algorithm for practical applications. The proposed algorithm not only solves the problem of in-plane rotation-invariance rationally, but also meets the real-time requirement. This paper ends with a comparison of the proposed method and the previous one. (classical areas of phenomenology)

  8. Computer-based image analysis in radiological diagnostics and image-guided therapy: 3D-Reconstruction, contrast medium dynamics, surface analysis, radiation therapy and multi-modal image fusion

    International Nuclear Information System (INIS)

    Beier, J.

    2001-01-01

    This book deals with substantial subjects of postprocessing and analysis of radiological image data, a particular emphasis was put on pulmonary themes. For a multitude of purposes the developed methods and procedures can directly be transferred to other non-pulmonary applications. The work presented here is structured in 14 chapters, each describing a selected complex of research. The chapter order reflects the sequence of the processing steps starting from artefact reduction, segmentation, visualization, analysis, therapy planning and image fusion up to multimedia archiving. In particular, this includes virtual endoscopy with three different scene viewers (Chap. 6), visualizations of the lung disease bronchiectasis (Chap. 7), surface structure analysis of pulmonary tumors (Chap. 8), quantification of contrast medium dynamics from temporal 2D and 3D image sequences (Chap. 9) as well as multimodality image fusion of arbitrary tomographical data using several visualization techniques (Chap. 12). Thus, the software systems presented cover the majority of image processing applications necessary in radiology and were entirely developed, implemented and validated in the clinical routine of a university medical school. (orig.) [de

  9. Vision Analysis System for Autonomous Landing of Micro Drone

    Directory of Open Access Journals (Sweden)

    Skoczylas Marcin

    2014-12-01

    Full Text Available This article describes a concept of an autonomous landing system of UAV (Unmanned Aerial Vehicle. This type of device is equipped with the functionality of FPV observation (First Person View and radio broadcasting of video or image data. The problem is performance of a system of autonomous drone landing in an area with dimensions of 1m × 1m, based on CCD camera coupled with an image transmission system connected to a base station. Captured images are scanned and landing marker is detected. For this purpose, image features detectors (such as SIFT, SURF or BRISK are utilized to create a database of keypoints of the landing marker and in a new image keypoints are found using the same feature detector. In this paper results of a framework that allows detection of defined marker for the purpose of drone landing field positioning will be presented.

  10. A Lagrangian cylindrical coordinate system for characterizing dynamic surface geometry of tubular anatomic structures.

    Science.gov (United States)

    Lundh, Torbjörn; Suh, Ga-Young; DiGiacomo, Phillip; Cheng, Christopher

    2018-03-03

    Vascular morphology characterization is useful for disease diagnosis, risk stratification, treatment planning, and prediction of treatment durability. To quantify the dynamic surface geometry of tubular-shaped anatomic structures, we propose a simple, rigorous Lagrangian cylindrical coordinate system to monitor well-defined surface points. Specifically, the proposed system enables quantification of surface curvature and cross-sectional eccentricity. Using idealized software phantom examples, we validate the method's ability to accurately quantify longitudinal and circumferential surface curvature, as well as eccentricity and orientation of eccentricity. We then apply the method to several medical imaging data sets of human vascular structures to exemplify the utility of this coordinate system for analyzing morphology and dynamic geometric changes in blood vessels throughout the body. Graphical abstract Pointwise longitudinal curvature of a thoracic aortic endograft surface for systole and diastole, with their absolute difference.

  11. Army medical imaging system: ARMIS

    International Nuclear Information System (INIS)

    Siedband, M.P.; Kramp, D.C.

    1987-01-01

    Recent advances of stimulable phosphor screens, data cards using optical storage means, and new personal computers with image processing capability have made possible the design of economical filmless medical imaging systems. The addition of communication links means that remote interpretation of images is also possible. The Army Medical Imaging System uses stimulable phosphor screens, digital readout, a small computer, an optical digital data card device, and a DIN/PACS link. Up to 200 images can be stored in the computer hard disk for rapid recall and reading by the radiologist. The computer permits image processing, annotation, insertion of text, and control of the system. Each device contains an image storage RAM and communicates with the computer via the small computer systems interface. Data compression is used to reduce the required storage capacity and transmission times of the 1-mB images. The credit card-size optical data cards replace film and can store 12 or more images. The data cards can be read on an independent viewer. The research is supported by the U.S. Army Biomedical Research and Development Laboratory

  12. Study on municipal road cracking and surface deformation based on image recognition

    Science.gov (United States)

    Yuan, Haitao; Wang, Shuai; Tan, Jizong

    2017-05-01

    In recent years, the digital image recognition technology of concrete structure cracks and deformation of binocular vision technology detection of civil engineering structure have made substantial development. As a result, people's understanding of the road engineering structure cracking and surface deformation recognition gives rise to a new situation. For the research on digital image concrete structure cracking and masonry structure surface deformation recognition technology, the key is to break through in the method, and to improve the traditional recognition technology and mode. Only in this way can we continuously improve the security level of the highway, to adapt to the new requirements of the development of new urbanization and modernization. This thesis focuses on and systematically analyzes the digital image road engineering structure cracking and key technologies of surface deformation recognition and its engineering applications. In addition, we change the concrete structure cracking and masonry structure surface deformation recognition pattern, and realize the breakthrough and innovation of the road structure safety testing means and methods.

  13. Design of low noise imaging system

    Science.gov (United States)

    Hu, Bo; Chen, Xiaolai

    2017-10-01

    In order to meet the needs of engineering applications for low noise imaging system under the mode of global shutter, a complete imaging system is designed based on the SCMOS (Scientific CMOS) image sensor CIS2521F. The paper introduces hardware circuit and software system design. Based on the analysis of key indexes and technologies about the imaging system, the paper makes chips selection and decides SCMOS + FPGA+ DDRII+ Camera Link as processing architecture. Then it introduces the entire system workflow and power supply and distribution unit design. As for the software system, which consists of the SCMOS control module, image acquisition module, data cache control module and transmission control module, the paper designs in Verilog language and drives it to work properly based on Xilinx FPGA. The imaging experimental results show that the imaging system exhibits a 2560*2160 pixel resolution, has a maximum frame frequency of 50 fps. The imaging quality of the system satisfies the requirement of the index.

  14. Development of an MRI/x-ray/ultrasound compatible marker for pre-operative breast tumour localization

    International Nuclear Information System (INIS)

    Li Yangmei; Wang, Jianxiong; Holloway, Claire; Plewes, Donald B

    2005-01-01

    This paper describes an in vitro investigation into the composition, structure and development of an magnetic resonance imaging (MRI), ultrasound (US) and x-ray imaging compatible marker for breast tumour localization. The marker is composed of 0.4-0.6 mm glass and iron-containing aluminium microspheres suspended in a gelatin matrix. The final form of the marker is a cylindrical shape 7 mm long with 2.05 mm diameter to facilitate delivery through a 12 gauge biopsy needle. To get optimal reflectivity for the US contrast, the glass microsphere concentration was found to be 40% by weight. US contrast is independent of marker orientation and the cylindrical shape made its US signal appearance distinctive thus ensuring confident identification. To control the MRI contrast, iron content was varied to generate a clear and local susceptibility signal void to reflect the marker position. Optimal iron content was found to be 52 μg iron which produced a clear signal void in spoiled gradient recalled MR images. The appearance of the susceptibility artefact is determined by the marker's shape, orientation and echo time. The final marker produces a dark artefact in MRI while appears as a clear hyperintense structure with acoustic shadowing in US images. The x-ray image showed the marker as a radio-opaque structure. This in vitro study demonstrates that the marker forms an alternative to traditional wire localization currently used for breast surgical procedures and creates new opportunities for US guided surgical procedures

  15. Self-consistent density functional calculation of the image potential at a metal surface

    International Nuclear Information System (INIS)

    Jung, J; Alvarellos, J E; Chacon, E; GarcIa-Gonzalez, P

    2007-01-01

    It is well known that the exchange-correlation (XC) potential at a metal surface has an image-like asymptotic behaviour given by -1/4(z-z 0 ), where z is the coordinate perpendicular to the surface. Using a suitable fully non-local functional prescription, we evaluate self-consistently the XC potential with the correct image behaviour for simple jellium surfaces in the range of metallic densities. This allows a proper comparison between the corresponding image-plane position, z 0 , and other related quantities such as the centroid of an induced charge by an external perturbation. As a by-product, we assess the routinely used local density approximation when evaluating electron density profiles, work functions, and surface energies by focusing on the XC effects included in the fully non-local description

  16. Self-consistent density functional calculation of the image potential at a metal surface

    Energy Technology Data Exchange (ETDEWEB)

    Jung, J [Departamento de Fisica Fundamental, Universidad Nacional de Educacion a Distancia, Apartado 60141, 28080 Madrid (Spain); Alvarellos, J E [Departamento de Fisica Fundamental, Universidad Nacional de Educacion a Distancia, Apartado 60141, 28080 Madrid (Spain); Chacon, E [Instituto de Ciencias de Materiales de Madrid, Consejo Superior de Investigaciones CientIficas, E-28049 Madrid (Spain); GarcIa-Gonzalez, P [Departamento de Fisica Fundamental, Universidad Nacional de Educacion a Distancia, Apartado 60141, 28080 Madrid (Spain)

    2007-07-04

    It is well known that the exchange-correlation (XC) potential at a metal surface has an image-like asymptotic behaviour given by -1/4(z-z{sub 0}), where z is the coordinate perpendicular to the surface. Using a suitable fully non-local functional prescription, we evaluate self-consistently the XC potential with the correct image behaviour for simple jellium surfaces in the range of metallic densities. This allows a proper comparison between the corresponding image-plane position, z{sub 0}, and other related quantities such as the centroid of an induced charge by an external perturbation. As a by-product, we assess the routinely used local density approximation when evaluating electron density profiles, work functions, and surface energies by focusing on the XC effects included in the fully non-local description.

  17. Artificial intelligence and medical imaging. Expert systems and image analysis

    International Nuclear Information System (INIS)

    Wackenheim, A.; Zoellner, G.; Horviller, S.; Jacqmain, T.

    1987-01-01

    This paper gives an overview on the existing systems for automated image analysis and interpretation in medical imaging, especially in radiology. The example of ORFEVRE, the system for the analysis of CAT-scan images of the cervical triplet (c3-c5) by image analysis and subsequent expert-system is given and discussed in detail. Possible extensions are described [fr

  18. Highly integrated image sensors enable low-cost imaging systems

    Science.gov (United States)

    Gallagher, Paul K.; Lake, Don; Chalmers, David; Hurwitz, J. E. D.

    1997-09-01

    The highest barriers to wide scale implementation of vision systems have been cost. This is closely followed by the level of difficulty of putting a complete imaging system together. As anyone who has every been in the position of creating a vision system knows, the various bits and pieces supplied by the many vendors are not under any type of standardization control. In short, unless you are an expert in imaging, electrical interfacing, computers, digital signal processing, and high speed storage techniques, you will likely spend more money trying to do it yourself rather than to buy the exceedingly expensive systems available. Another alternative is making headway into the imaging market however. The growing investment in highly integrated CMOS based imagers is addressing both the cost and the system integration difficulties. This paper discusses the benefits gained from CMOS based imaging, and how these benefits are already being applied.

  19. Surface Plasmon Resonance Imaging of the Enzymatic Degradation of Cellulose Microfibrils

    Science.gov (United States)

    Reiter, Kyle; Raegen, Adam; Clarke, Anthony; Lipkowski, Jacek; Dutcher, John

    2012-02-01

    As the largest component of biomass on Earth, cellulose represents a significant potential energy reservoir. Enzymatic hydrolysis of cellulose into fermentable sugars, an integral step in the production of biofuel, is a challenging problem on an industrial scale. More efficient conversion processes may be developed by an increased understanding of the action of the cellulolytic enzymes involved in cellulose degradation. We have used our recently developed quantitative, angle-scanning surface plasmon resonance imaging (SPRi) device to study the degradation of cellulose microfibrils upon exposure to cellulosic enzymes. In particular, we have studied the action of individual enzymes, and combinations of enzymes, from the Hypocrea Jecorina cellulase system on heterogeneous, industrially-relevant cellulose substrates. This has allowed us to define a characteristic time of action for the enzymes for different degrees of surface coverage of the cellulose microfibrils.

  20. Searching for non-genetic molecular and imaging PTSD risk and resilience markers: Systematic review of literature and design of the German Armed Forces PTSD biomarker study.

    Science.gov (United States)

    Schmidt, Ulrike; Willmund, Gerd-Dieter; Holsboer, Florian; Wotjak, Carsten T; Gallinat, Jürgen; Kowalski, Jens T; Zimmermann, Peter

    2015-01-01

    Biomarkers allowing the identification of individuals with an above average vulnerability or resilience for posttraumatic stress disorder (PTSD) would especially serve populations at high risk for trauma exposure like firefighters, police officers and combat soldiers. Aiming to identify the most promising putative PTSD vulnerability markers, we conducted the first systematic review on potential imaging and non-genetic molecular markers for PTSD risk and resilience. Following the PRISMA guidelines, we systematically screened the PubMed database for prospective longitudinal clinical studies and twin studies reporting on pre-trauma and post-trauma PTSD risk and resilience biomarkers. Using 25 different combinations of search terms, we retrieved 8151 articles of which we finally included and evaluated 9 imaging and 27 molecular studies. In addition, we briefly illustrate the design of the ongoing prospective German Armed Forces (Bundeswehr) PTSD biomarker study (Bw-BioPTSD) which not only aims to validate these previous findings but also to identify novel and clinically applicable molecular, psychological and imaging risk, resilience and disease markers for deployment-related psychopathology in a cohort of German soldiers who served in Afghanistan. Copyright © 2014 Elsevier Ltd. All rights reserved.