WorldWideScience

Sample records for surface mass injection

  1. Liquid chromatography-tandem mass spectrometry direct injection analysis of organophosphorus flame retardants in Ontario surface water and wastewater effluent.

    Science.gov (United States)

    Hao, Chunyan; Helm, Paul A; Morse, David; Reiner, Eric J

    2018-01-01

    Organophosphorus flame retardants (OPFRs) started to be used in plastics, electronics and furnishings back in the 1960s and became popular again last decade. They are now widely present in the environment and regarded as "new" emerging organic pollutants. An effective liquid chromatography-tandem mass spectrometry (LC-MS/MS) direct injection analysis (DIA) method was developed to monitor OPFR levels in aquatic environment. The removal of sample extraction and concentration steps not only improved operation efficiency, but also reduced the potential contamination commonly observed during the sample preparation process before. Positive background signals from the analytical instrument were eliminated by employing a "trap" column in front of the sample injector while an ACE C18 and an ACE C18-PFP column were compared for the separation of OPFRs. Nineteen OPFR related compounds were evaluated and rapid signal drops were observed for seven of them including TOTP, TMTP, TPTP, TEHP, T35DMPP, T2iPPP and EHDP, due to their low water solubility. The other twelve compounds, TMP, TEP, TPrP, TiPP, TBP, TCEP, TCPP, TDCPP, TPP, TBEP, BDCP and BEHP, were included for the measurement of OPFRs in drinking water, surface water, ground water and wastewater effluent samples. The instrumental detection limits of these twelve OPFRs at signal-to-noise ≥3 were in the 1.5-30 ng/L range. The method was applied for the determination of OPFRs in surface water and wastewater samples in Ontario, Canada, and BEHP, TBEP, TBP, TCEP, TCPP, TDCPP, and TEP were commonly detected. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  2. Surface Microstructure Replication in Injection Moulding

    DEFF Research Database (Denmark)

    Hansen, Hans Nørgaard; Arlø, Uffe Rolf

    2005-01-01

    topography is transcribed onto the plastic part through complex mechanisms. This replication however, is not perfect, and the replication quality depends on the plastic material properties, the topography itself, and the process conditions. This paper describes and discusses an investigation of injection......In recent years polymer components with surface microstructures have been in rising demand for applications such as lab-on-a-chip and optical components. Injection moulding has proven to be a feasible and efficient way to manufacture such components. In injection moulding the mould surface...... moulding of surface microstructures. Emphasis is put on the ability to replicate surface microstructures under normal injection moulding conditions, notably with low cost materials at low mould temperatures. The replication of surface microstructures in injection moulding has been explored...

  3. Surface micro topography replication in injection moulding

    DEFF Research Database (Denmark)

    Arlø, Uffe Rolf

    , the topography itself, and other factors were also investigated. The experimental work is based on a multi-purpose experimental injection mould with a collection of test surface inserts manufactured by EDM (electrical discharge machining). Experimental production took place with an injection moulding machine...

  4. Injection molded self-cleaning surfaces

    DEFF Research Database (Denmark)

    Søgaard, Emil

    This PhD thesis concerns the development of superhydrophobic surfaces fabricated by injection molding. Today, injection molding is the prevalent production method for consumer plastic products. However, concerns regarding the environmental impact of a plastic production are increasing, especially...... because the use of potentially toxic self-cleaning coatings is used worldwide in a larger and larger scale. In this context, the work in this PhD project could be seen as a scientific effort towards reducing toxic compounds in manufactured plastic parts by developing injecting molded surfaces......° for structured surfaces with a drop roll-off angle of less than 2°. Thereby, it is shown that an extremely water repellant surface can be injection molded directly with clear perspectives for more environmental and healthier plastic consumer products....

  5. Injection optics for fast mass switching for accelerator mass spectrometry

    Science.gov (United States)

    Weisser, D. C.; Fifield, L. K.; De Cesare, M.; Tims, S. G.; Lobanov, N. R.; Crook, G. G.; Tsifakis, D.; Tunningley, T. B.

    2013-04-01

    Accelerator Mass Spectrometry (AMS) measures the ratio of extremely small amounts of a radioactive isotope in the presence of ˜ 1015 times more stable ones. The isotopes are injected sequentially over a repeated period and observed at the exit of the accelerator. so any fluctuations in ion source output or transmission through the accelerator over a time comparable to the measurement time, will reduce the accuracy of such measurements. This compromise in accuracy can be lessened by reducing the switching time between isotopes from several seconds to a few milli-seconds. New AMS systems accomplish fast switching by modifying the beam energy though the 90 injection magnet by pulsing the voltage by several kV on the flight tube in the magnet. That requires that the flight tube be electrically insulated which competes with having the flight tube as large as possible. At the ANU, insulating the magnet flight tube would not only have reduced the acceptance of the injection system, but conflicted with a beam chopper attached to the flight tube, that would also have had to be insulated from the ground. This was not practical so the novel alternative of pulsing the voltage on the high voltage ion source deck is being implemented. Beam optics calculations have been performed and beam tests conducted that demonstrated that, in addition to pulsing the voltage on the 150 kV ion source deck, a pulsed Einzel lens in front of the following electrostatic quadrupole triplet lens is required to maintain isotope-independent transmission through the 14UD Pelletron accelerator. The high voltage rise time performance of the components of the system has been shown to be satisfactory.

  6. Imprinted and injection-molded nano-structured optical surfaces

    DEFF Research Database (Denmark)

    Christiansen, Alexander Bruun; Højlund-Nielsen, Emil; Clausen, Jeppe Sandvik

    2013-01-01

    . In this paper, nanostructured polymer surfaces suitable for up-scalable polymer replication methods, such as imprinting/embossing and injection-molding, are discussed. The limiting case of injection-moulding compatible designs is investigated. Anti-reflective polymer surfaces are realized by replication...... of light from polymer surfaces and their implication for creating structural colors is discussed. In the case of injection-moulding compatible designs, the maximum reflection of nano-scale textured surfaces cannot exceed the Fresnel reflection of a corresponding flat polymer surface, which is approx. 4...

  7. Near-surface groundwater responses to injection of geothermal wastes

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, S.C.

    1984-06-01

    Experiences with injecting geothermal fluids have identified technical problems associated with geothermal waste disposal. This report assesses the feasibility of injection as an alternative for geothermal wastewater disposal and analyzes hydrologic controls governing the upward migration of injected fluids. Injection experiences at several geothermal developments are presented, including: Raft River, Salton Sea, East Mesa, Otake and Hatchobaru in Japan, and Ahuachapan in El Salvador. Hydrogeologic and design/operational factors affecting the success of an injection program are identified. Hydrogeologic factors include subsidence, near-surface effects of injected fluids, and seismicity. Design/operational factors include hydrodynamic breakthrough, condition of the injection system and reservoir maintenance. Existing and potential effects of production/injection on these factors are assessed.

  8. Surface microstructure replication in injection molding

    DEFF Research Database (Denmark)

    Theilade, Uffe Arlø; Hansen, Hans Nørgaard

    2006-01-01

    molding of surface microstructures. The fundamental problem of surface microstructure replication has been studied. The research is based on specific microstructures as found in lab-on-a-chip products and on rough surfaces generated from EDM (electro discharge machining) mold cavities. Emphasis is put...

  9. Image resolution influence on determination of resin injection rock mass

    Science.gov (United States)

    Wang, Weixing; Hakami, Eva

    2006-01-01

    In the context of nuclear waste repositories, an important approach to understanding brittle rock mass behavior to integrate new and powerful observational and numerical methods with multi-functional 3-D imaging and visualization techniques. Since 1994, Swedish Nuclear Fuel and Waste Management Company (SKB) have identified the need for a better understanding of radionuclide transport and retention processes in fractured rock. As a cooperation project between Sweden and China, we sampled a number of rock specimens for analyze rock fracture network by optical image technique. The samples are resin injected, in which way; opened fractures can be seen clearly by means of UV (Ultraviolet) light illumination. In the study period, we used different optical focuses to obtain the images from the same samples; we found that Image resolution influences on porosity determination of resin injected rock mass. This paper presents and discusses the six issues based on our research results: (1) Fracture porosity increases as camera focus distance decreases; (2) Porosity increases as illumination increases in resin injected fracture images; (3) To roughly estimate the porosity, the low resolution image can be used; (4) To collect more details of fracture information, the high resolution image is needed; (5) The resolution of image should be determined based on the aim of fracture analysis; (6) To acquire high resolution image, constructing a special illumination (standard) box maybe helpful to avoid light reflection and diffusion.

  10. Packing parameters effect on injection molding of polypropylene nanostructured surfaces

    DEFF Research Database (Denmark)

    Calaon, Matteo; Tosello, Guido; Hansen, Hans Nørgaard

    2012-01-01

    In today´s industry, applications involving surface patterning of sub-μm to nanometer scale structures have shown a high growth potential. To investigate the injection molding capability of replicating sub-μm surface texture on a large scale area, a 30x80 mm2 tool insert with surface structures...... having a diameter of 500 nm was employed. The tool insert surface was produced using chemical-based-batch techniques such aluminum anodization and nickel electroplating. During the injection molding process, polypropylene (PP) was employed as material and packing phase parameters (packing time, packing...

  11. Surface Micro Topography Replication in Injection Moulding

    DEFF Research Database (Denmark)

    Arlø, Uffe Rolf; Hansen, Hans Nørgaard; Kjær, Erik Michael

    2005-01-01

    carried out with rough EDM (electrical discharge machining) mould surfaces, a PS grade, and by applying established three-dimensional topography parameters. Significant quantitative relationships between process parameters and topography parameters were established. It further appeared that replication...

  12. Surface wear of TiN coated nickel tool during the injection moulding of polymer micro Fresnel lenses

    DEFF Research Database (Denmark)

    Tosello, Guido; Hansen, Hans Nørgaard; Gasparin, Stefania

    2012-01-01

    Limited tool life of nickel mould inserts represents an issue for the mass-production of polymer optics with complex micro three-dimensional geometries by injection moulding. TiN coating was applied to a nickel insert for the injection moulding of polycarbonate micro Fresnel lenses. Surface wear ...

  13. On the Injection Molding of Nanostructured Polymer Surfaces

    DEFF Research Database (Denmark)

    Pranov, Henrik; Rasmussen, Henrik K.; Larsen, Niels Bent

    2006-01-01

    ranged from 310 to 3100 rim. All the pillars were 220 nm high. The nickel-shim was used as a surface-template during injection molding of polycarbonate. Secondly, a nickel shim, with a surface pattern consisted of a squared sine with a period of 700 nm and amplitude of 450 nm, was mounted on...... with a clean shim and a shim coated with a monolayer of fluorocarbonsilane. As a result of the surface coating, the amplitude of the replicated grating decreased from about 350 nm in polycarbonate and 100 nm in polystyrene to less than 10 nm. The experiments strongly suggest that the possibility to injection...... mold sub-micrometer surface structures in polymers mainly relates to adhesive energy between polymer and shim....

  14. Assessment methods of injection moulded nano-patterned surfaces

    DEFF Research Database (Denmark)

    Menotti, S.; Bisacco, G.; Hansen, H. N.

    2014-01-01

    algorithm for feature recognition. To compare the methods, the mould insert and a number of replicated nano-patterned surfaces, injection moulded with an induction heating aid, were measured on nominally identical locations by means of an atomic force microscope mounted on a manual CMM....

  15. Applicability of the direct injection liquid chromatographic tandem mass spectrometric analytical approach to the sub-ngL-1 determination of perfluoro-alkyl acids in waste, surface, ground and drinking water samples.

    Science.gov (United States)

    Ciofi, Lorenzo; Renai, Lapo; Rossini, Daniele; Ancillotti, Claudia; Falai, Alida; Fibbi, Donatella; Bruzzoniti, Maria Concetta; Santana-Rodriguez, José Juan; Orlandini, Serena; Del Bubba, Massimo

    2018-01-01

    The applicability of a direct injection UHPLC-MS/MS method for the analysis of several perfluoroalkyl acids (PFAAs) in a wide range of water matrices was investigated. The method is based on the direct injection of 100µL of centrifuged water sample, without any other sample treatment. Very good method detection limits (0.014-0.44ngL -1 ) and excellent intra and inter-day precision (RSD% values in the range 1.8-4.4% and 2.7-5.7%, respectively) were achieved, with a total analysis time of 20min per sample. A high number of samples - i.e. 8 drinking waters (DW), 12 ground waters (GW), 13 surface waters (SW), 8 influents and 11 effluents of wastewater treatment plants (WWTP IN and WWTP OUT ) were processed and the extent of matrix effect (ME) was calculated, highlighting the strong prevalence of |ME| 50% was occasionally observed only for perfluorooctanesulphonic and perfluorodecanoic acids. Linear discriminant analysis highlighted the great contribution of the sample origin (i.e. DW, GW, SW, WWTP IN and WWTP OUT ) to the ME. Partial least square regression (PLS) and leave-one-out cross-validation were performed in order to interpret and predict the signal suppression or enhancement phenomena as a function of physicochemical parameters of water samples (i.e. conductivity, hardness and chemical oxygen demand) and background chromatographic area. The PLS approach resulted only in an approximate screening, due to the low prediction power of the PLS models. However, for most analytes in most samples, the fitted and cross-validated values were such as to correctly distinguish between | ME | higher than 20% or below this limit. PFAAs in the aforementioned water samples were quantified by means of the standard addition method, highlighting their occurrence mainly in WWTP influents and effluents, at concentrations as high as one hundred of µgL -1 . Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Injection Moulding of Plastic Parts with Surface Microstructures

    DEFF Research Database (Denmark)

    Arlø, Uffe Rolf; Hansen, Hans Nørgaard; Kjær, Erik Michael

    2003-01-01

    In this study the replication of surface microstructures in injection moulding has been explored for Polypropylene at low mould temperatures. The issue of the physical mechanisms controlling replication has also been addressed. The mould micro geometries applied are essentially 2½D rectangular...... structures with heights of 9 µm and aspect ratios from 0.2 to 1. For topographical characterisation a confocal laser scanning microscope was used. The injection moulding process conditions were varied over the recommended process window for the material, and the process was analysed using commercial...

  17. Two-component injection moulding simulation of ABS-POM micro structured surfaces

    DEFF Research Database (Denmark)

    Tosello, Guido; Hansen, Hans Nørgaard; Islam, Aminul

    2013-01-01

    Multi-component micro injection moulding (μIM) processes such as two-component (2k) μIM are the key technologies for the mass fabrication of multi-material micro products. 2k-μIM experiments involving a miniaturized test component with micro features in the sub-mm dimensional range and moulding a...... process. Flow front predictions are compared with experimental results using the short shots technique over the whole miniaturized component and within the surface micro structures....

  18. Surface ionization mass spectrometry of opiates

    International Nuclear Information System (INIS)

    Usmanov, D.T.

    2009-07-01

    Key words: surface ionization, adsorption, heterogeneous reactions, surface ionization mass spectrometry, thermodesorption surface ionization spectroscopy, thermoemitter, opiates, extracts of biosamples. Subjects of study. The mass - spectrometric study of thermal - ion emission: surface ionization of opiates by on the surface of oxidized refractory metals. Purpose of work is to establish the regularities of surface ionization (SI) of multi-atomic molecule opiates and their mixtures develop the scientific base of SI methods for high sensitive and selective detection and analysis of these substances in the different objects, including biosamples. Methods of study: surface ionization mass spectrometry, thermodesorption surface ionization spectroscopy. The results obtained and their novelty. For the first time, SI of molecule opiates on the oxidized tungsten surface has been studied and their SI mass-spectra and temperature dependences of ion currents have been obtained, the characteristic heterogeneous reactions of an adsorbed molecules and the channels of monomolecular decays vibrationally-excited ions on their way in mass-spectrometry have been revealed, sublimation energy has been defined, the activation energy of E act , of these decays has been estimated for given period of time. Additivity of the SI mass-spectra of opiate mixtures of has been established under conditions of joint opiate adsorption. High selectivity of SI allows the extracts of biosamples to be analyzed without their preliminary chromatographic separation. The opiates are ionized by SI with high efficiency (from 34 C/mol to 112 C/mol), which provides high sensitivity of opiate detection by SI/MS and APTDSIS methods from - 10 -11 g in the samples under analysis. Practical value. The results of these studies create the scientific base for novel SI methods of high sensitive detection and analysis of the trace amounts of opiates in complicated mixtures, including biosamples without their preliminary

  19. A wide variety of injection molding technologies is now applicable to small series and mass production

    Science.gov (United States)

    Bloß, P.; Jüttner, G.; Jacob, S.; Löser, C.; Michaelis, J.; Krajewsky, P.

    2014-05-01

    Micro plastic parts open new fields for application, e. g., to electronics, sensor technologies, optics, and medical engineering. Before micro parts can go to mass production, there is a strong need of having the possibility for testing different designs and materials including material combinations. Hence, flexible individual technical and technological solutions for processing are necessary. To manufacture high quality micro parts, a micro injection moulding machine named formicaPlast based on a two-step plunger injection technology was developed. Resulting from its design, the residence time and the accuracy problems for managing small shot volumes with reproducible high accuracy are uncompromisingly solved. Due to their simple geometry possessing smooth transitions and non adherent inner surfaces, the plunger units allow to process "all" thermoplastics from polyolefines to high performance polymers, optical clear polymers, thermally sensitive bioresorbables, highly filled systems (the so-called powder injection molding PIM), and liquid silicon rubber (LSR, here with a special kit). The applied platform strategy in the 1K and 2K version allows integrating automation for assembling, handling and packaging. A perpendicular arrangement allows encapsulation of inserts, also partially, and integration of this machine into process chains. Considering a wide variety of different parts consisting of different materials, the high potential of the technology is demonstrated. Based on challenging industrial parts from electronic applications (2K micro MID and bump mat, where both are highly structured parts), the technological solutions are presented in more detail.

  20. A wide variety of injection molding technologies is now applicable to small series and mass production

    International Nuclear Information System (INIS)

    Bloß, P.; Jüttner, G.; Jacob, S.; Löser, C.; Michaelis, J.; Krajewsky, P.

    2014-01-01

    Micro plastic parts open new fields for application, e. g., to electronics, sensor technologies, optics, and medical engineering. Before micro parts can go to mass production, there is a strong need of having the possibility for testing different designs and materials including material combinations. Hence, flexible individual technical and technological solutions for processing are necessary. To manufacture high quality micro parts, a micro injection moulding machine named formicaPlast based on a two-step plunger injection technology was developed. Resulting from its design, the residence time and the accuracy problems for managing small shot volumes with reproducible high accuracy are uncompromisingly solved. Due to their simple geometry possessing smooth transitions and non adherent inner surfaces, the plunger units allow to process 'all' thermoplastics from polyolefines to high performance polymers, optical clear polymers, thermally sensitive bioresorbables, highly filled systems (the so-called powder injection molding PIM), and liquid silicon rubber (LSR, here with a special kit). The applied platform strategy in the 1K and 2K version allows integrating automation for assembling, handling and packaging. A perpendicular arrangement allows encapsulation of inserts, also partially, and integration of this machine into process chains. Considering a wide variety of different parts consisting of different materials, the high potential of the technology is demonstrated. Based on challenging industrial parts from electronic applications (2K micro MID and bump mat, where both are highly structured parts), the technological solutions are presented in more detail

  1. Evolution of Surface Texture and Cracks During Injection Molding of Fiber-Reinforced, Additively-Manufactured, Injection Molding Inserts

    DEFF Research Database (Denmark)

    Hofstätter, Thomas; Mischkot, Michael; Pedersen, David Bue

    2016-01-01

    This paper investigates the lifetime and surfacedeterioration of additively-manufactured, injection-moulding inserts. The inserts were produced using digital light processing and were reinforcedwith oriented short carbon fibers. Theinserts were used during injection molding oflow......-density polyethylene until their failure. The molded products were used to analyse the development of the surface roughness and wear. By enhancing the lifetime of injection-molding inserts,this work contributes to the establishment of additively manufactured inserts in pilot production....

  2. PROTVINO: Mass-production of scintillator tiles by injection moulding

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    The technique of the segmented sandwich-calorimeters with wavelength-shifting readout, especially its large-scale application in big detectors, requires enormous quantities of a cheap scintillator tiles of moderate dimensions (20 x 20 cm 2 ). Initial trials carried out in the Institute for High Energy Physics (IHEP), Protvino, Russia almost ten years ago showed that manufacturing such scintillator tiles was possible using an ordinary commercially-available granulated optical polystyrene, an existing technology of plastic dyeing, and a well-known process of the injection moulding, used to produce plastic goods (like buttons!)

  3. Near-surface groundwater responses to injection of geothermal wastes

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, S.C.

    1984-06-01

    This report assesses the feasibility of injection as an alternative for geothermal wastewater disposal and analyzes hydrologic controls governing the upward migration of injected fluids. Injection experiences at several geothermal developments are presented including the following: Raft River Valley, Salton Sea, East Mesa, Otake, Hatchobaru, and Ahuachapan geothermal fields.

  4. Dissipation on Steady MHD Marangoni Convection Flow over a Flat Surface with Suction and Injection

    Directory of Open Access Journals (Sweden)

    S. Mohammed Ibrahim

    2013-01-01

    Full Text Available The combined effects of radiation and mass transfer on a steady MHD two-dimensional Marangoni convection flow over a flat surface in presence of Joule heating and viscous dissipation under influence of suction and injection is studied numerically. The general governing partial differential equations are transformed into a set of nonlinear ordinary differential equations by using unique similarity transformation. Numerical solutions of the similarity equations are obtained using the Runge-Kutta method along with shooting technique. The effects of governing parameters on velocity, temperature, and concentration as well as interface velocity, the surface temperature gradient, and the surface concentration gradient were presented in graphical and tabular forms. Comparisons with previously published work are performed and the results are found to be in excellent agreement.

  5. Contaminant mass estimation of powder contaminated surfaces

    Science.gov (United States)

    Gibbs, Timothy J.; Messinger, David W.

    2017-05-01

    How can we determine the physical characteristics of a mixture of multiple materials within a single pixel? Intimate mixing occurs when different materials within the region encompassed by a pixel interact with each other prior to reaching the sensor. For powder contaminated surfaces, nonlinear mixing is unavoidable. The Nonconventional Exploitation Factors Data System (NEFDS) Contamination Model can make longwave hyperspectral mixture signatures, but only for a small subset of their spectral library. In addition, the model uses percent coverage as its only physical property input despite it not being informative to the contaminants physical properties. Through a complex parameter inversion, the NEFDS contamination model can be used to derive various physical properties. These physical characteristics were estimated by using empirically measured data of varying contaminant amounts using a Designs and Prototypes Fourier transform infrared spectrometer. Once estimated parameters are found, the mixture spectra was recreated and compared to the measured data. The estimated areal coverage density is used to derive a total deposited mass on the surface based on the area of contaminated surface. This is compared to the known amount deposited that was measured during the experimental campaign. This paper presents some results of those measurements and model estimates.

  6. Injected mass deposition thresholds for lithium granule instigated triggering of edge localized modes on EAST

    Science.gov (United States)

    Lunsford, R.; Sun, Z.; Maingi, R.; Hu, J. S.; Mansfield, D.; Xu, W.; Zuo, G. Z.; Diallo, A.; Osborne, T.; Tritz, K.; Canik, J.; Huang, M.; Meng, X. C.; Gong, X. Z.; Wan, B. N.; Li, J. G.; the EAST team

    2018-03-01

    The ability of an injected lithium granule to promptly trigger an edge localized mode (ELM) has been established in multiple experiments. By horizontally injecting granules ranging in diameter from 200 microns to 1 mm in diameter into the low field side of EAST H-mode discharges we have determined that granules with diameter  >600 microns are successful in triggering ELMs more than 95% of the time. It was also demonstrated that below 600 microns the triggering efficiency decreased roughly with granule size. Granules were radially injected from the outer midplane with velocities ~80 m s‑1 into EAST upper single null discharges with an ITER like tungsten monoblock divertor. These granules were individually tracked throughout their injection cycle in order to determine their efficacy at triggering an ELM. For those granules of sufficient size, ELM triggering was a prompt response to granule injection. By simulating the granule injection with an experimentally benchmarked neutral gas shielding (NGS) model, the ablatant mass deposition required to promptly trigger an ELM is calculated and the fractional mass deposition is determined.

  7. Mass Production Tools and Process Readiness for Uniform Parts—Injection Molding Application

    DEFF Research Database (Denmark)

    Boorla, Srinivasa Murthy; Eifler, Tobias; Howard, Thomas J.

    2017-01-01

    A mass production always aims to produce uniform performing products. Production tools such as pressing dies, casting dies and injection moulds, play a significant role by producing uniform parts for achieving final products. Tool complexity increases when multiple cavities are present. These too...... and of finding opportunities to counter them. Application is assessed over a hypothetical plastic injection mould and found feasible. Proposed process could evaluate the tool capability for producing uniform parts, at its digital design verification and its physical validation.......A mass production always aims to produce uniform performing products. Production tools such as pressing dies, casting dies and injection moulds, play a significant role by producing uniform parts for achieving final products. Tool complexity increases when multiple cavities are present. These tools...

  8. Interfacing capillary electrophoresis with inductively coupled plasma mass spectrometry by direct injection nebulization for selenium speciation

    DEFF Research Database (Denmark)

    Bendahl, Lars; Gammelgaard, Bente; Jons, O.

    2001-01-01

    A demountable direct injection high efficiency nebulizer operating at low sample uptake rates was developed and used for coupling of capillary electrophoresis (CE) with inductively coupled plasma mass spectrometry (ICP-MS). When the nebulizer was used for continuous sample introduction, detection...

  9. Turbulent heat transfer on a permeable surface in the range of supercritical gas injections

    International Nuclear Information System (INIS)

    Kichatov, B.V.; Polyaev, V.M.

    1997-01-01

    Gas injection in a permeable surface is used as one of the most perspective ways of thermal protection. Forcing back of the boundary layer from the surface takes place by injection, whereby the friction coefficients and heat exchange are decreased. By certain injection parameter, which is called critical, there takes place the complete forcing back of the boundary layer from the surface. However the process of friction and heat exchange degeneration proceeds nonuniformly. This article is devoted to explanation of the above notice. Analysis of the problem is based on the limiting relative law of heat exchange and friction for a turbulent boundary layer

  10. Characterization methods of nano-patterned surfaces generated by induction heating assisted injection molding

    DEFF Research Database (Denmark)

    Tang, Peter Torben; Ravn, Christian; Menotti, Stefano

    2015-01-01

    An induction heating-assisted injection molding (IHAIM) process developed by the authors is used to replicate surfaces containing random nano-patterns. The injection molding setup is developed so that an induction heating system rapidly heats the cavity wall at rates of up to 10◦C/s. In order...

  11. Transcription of Small Surface Structures in Injection Moulding - An Experimental Study

    DEFF Research Database (Denmark)

    Arlø, Uffe Rolf; Kjær, Erik Michael

    2000-01-01

    The ability to replicate the surface roughness from mold wall to the plastic part in injection moldning has many functional and cosmetic important implications from medical use to designer products. Generally the understanding of surface transcription i.e the the replication of the surface...... structure from the mould to plastic part, also relates to micro injection moulding and moulding of parts with specific micro structures on the surface such as optical parts. The present study concerns transcription of surface roughness as a function of process parameters. The study is carried out...

  12. Transcription of Small Surface Structures in Injection Molding - an Experimental Study

    DEFF Research Database (Denmark)

    Arlø, Uffe Rolf; Kjær, Erik Michael

    2001-01-01

    The ability to replicate the surface roughness from mold wall to the plastic part in injection moldning has many functional and cosmetic important implications from medical use to designer products. Generally the understanding of surface transcription i.e the the replication of the surface...... structure from the mould to plastic part, also relates to micro injection moulding and moulding of parts with specific micro structures on the surface such as optical parts. The present study concerns transcription of surface roughness as a function of process parameters. The study is carried out...

  13. A control-oriented approach to estimate the injected fuel mass on the basis of the measured in-cylinder pressure in multiple injection diesel engines

    International Nuclear Information System (INIS)

    Finesso, Roberto; Spessa, Ezio

    2015-01-01

    Highlights: • Control-oriented method to estimate injected quantities from in-cylinder pressure. • Able to calculate the injected quantities for multiple injection strategies. • Based on the inversion of a heat-release predictive model. • Low computational time demanding. - Abstract: A new control-oriented methodology has been developed to estimate the injected fuel quantities, in real-time, in multiple injection DI diesel engines on the basis of the measured in-cylinder pressure. The method is based on the inversion of a predictive combustion model that was previously developed by the authors, and that is capable of estimating the heat release rate and the in-cylinder pressure on the basis of the injection rate. The model equations have been rewritten in order to derive the injected mass as an output quantity, starting from use of the measured in-cylinder pressure as input. It has been verified that the proposed method is capable of estimating the injected mass of pilot pulses with an uncertainty of the order of ±0.15 mg/cyc, and the total injected mass with an uncertainty of the order of ±0.9 mg/cyc. The main sources of uncertainty are related to the estimation of the in-cylinder heat transfer and of the isentropic coefficient γ = c p /c v . The estimation of the actual injected quantities in the combustion chamber can represent a powerful means to diagnose the behavior of the injectors during engine operation, and offers the possibility of monitoring effects, such as injector ageing and injector coking, as well as of allowing an accurate control of the pilot injected quantities to be obtained; the latter are in fact usually characterized by a large dispersion, with negative consequences on the combustion quality and emission formation. The approach is characterized by a very low computational time, and is therefore suitable for control-oriented applications.

  14. Mass microscopy : imaging biomolecules on surfaces

    NARCIS (Netherlands)

    Luxembourg, Stefan Libertus

    2005-01-01

    Now, that mass spectrometry (MS) has been established as the analytical tool for the analysis of proteins a new challenge awaits: the development of spatial resolved mass spectrometry directly on biological tissue and cells at single cell level or beyond. The desire to study the complexity of

  15. Injection and laser acceleration of ions based on the resonant surface photoionization

    International Nuclear Information System (INIS)

    Antsiferov, V.V.; Smirnov, G.I.; Telegin, G.G.

    1993-01-01

    The collective effects have been investigated of the injection and acceleration of the ion beams due to the resonant surface photoionization. The considered scheme of the laser accelerator allows to obtain positive ions with relativistic velocities. 11 refs., 2 figs

  16. Helicity injection with moving vacuum--plasma boundary with arbitrary flux surfaces

    International Nuclear Information System (INIS)

    Bellan, P.M.

    1988-01-01

    If a toroidal plasma has arbitrary nested magnetic flux surfaces and a moving plasma--vacuum interface, then any helicity injected by modulating the magnetic fields is simply consumed by an increase in helicity dissipation due to the modulated fields

  17. Replication of micro structured surface by injection moulding of PEEK

    DEFF Research Database (Denmark)

    Zhang, Yang; Hansen, Hans Nørgaard; Sørensen, Søren

    A micro-structured Ni insert was investigated for PEEK injection moulding. The micro features are circular holes 4 μm in diameter and 2 μm deep, with a 2 μm edge-to-edge distance. 6000 moulding cycles was operated. Half of the insert was coated by 200nm CrN. PEEK parts produced by the coated side...... and non-coated side were compared. Coating thickness was measured at intervals of production and employed to characterize the coating wear. Pillars geometry at fixed locations on PEEK parts was studied by SEM. EDS was conducted on the PEEK parts in order to study the Ni and Ag contamination. The results...... show the studied coating has a very low wear, and no Ni or Ag contamination on PEEK was detected for both parts produced by coated side and uncoated side. Coating improved demolding by reducing small indentations on pillars. The method to apply micro structured Ni plate on 3D parts injection moulding...

  18. Transport and transformation of surface water masses across the ...

    African Journals Online (AJOL)

    Transport and transformation of surface water masses across the Mascarene Plateau during the Northeast Monsoon season. ... Mixing occurs in the central gap between intermediate water masses (Red Sea Water [RSW] and Antarctic Intermediate Water [AAIW]) as well as in the upper waters (Subtropical Surface Water ...

  19. Improvements in the injection system of the Canadian Penning trap mass spectrometer

    CERN Document Server

    Clark, J; Boudreau, C; Buchinger, F; Crawford, J E; Gulick, S; Hardy, J C; Heinz, A; Lee, J K P; Moore, R B; Savard, G; Seweryniak, D; Sharma, K S; Sprouse, G; Vaz, J; Wang, J C; Zhou, Z

    2003-01-01

    The Canadian Penning Trap (CPT) mass spectrometer is designed to make precise mass measurements on a variety of stable and short-lived isotopes. Modifications to the injection system of the CPT have been implemented in recent months, the purpose being to more efficiently collect and transfer weakly-produced reaction products from the target to the Penning trap. These include a magnetic triplet situated after the target chamber to increase the acceptance of the Enge spectrograph, a velocity filter to more effectively separate the beam from the reaction products and the replacement of the Paul trap with a linear trap resulting in more efficient capture and accumulation of ions from the ion cooler. This paper will discuss these recent modifications and how they have increased our ability in making mass measurements on isotopes of low abundance, including those from a sup 2 sup 5 sup 2 Cf fission source.

  20. The effect of mold surface topography on plastic parat in-process shrinkage in injection molding

    DEFF Research Database (Denmark)

    Arlø, Uffe Rolf; Hansen, Hans Nørgaard; Kjær, Erik Michael

    2003-01-01

    An experimental study of the effect of mold surface roughness on in-process in-flow linear part shrinkage in injection molding has been carried out. The investigation is based on an experimental two-cavity tool, where the cavities have different surface topographies, but are otherwise identical...

  1. Surface Replication of Molded Products with Microneedle Features in Injection Molding

    Science.gov (United States)

    Uchiumi, Kazuyasu; Takayama, Tetsuo; Ito, Hiroshi; Inou, Akinori

    Micro-molding of microneedle features was conducted using several injection-molding techniques. Injection compression molding and injection molding were performed with supercritical carbon dioxide fluid and with or without vacuum processing inside the mold cavity. Effects of process parameters on processability and surface replication of the molded parts were evaluated. The height replication ratio for microneedles was improved using injection compression molding. At a shorter compression stroke, the needle height was improved, and the influence of compression delay time was also small. Moreover, the effects of vacuum processing inside the mold cavity under the filling process were slight. The height replication ratio for microneedles showed the highest values using injection molding using supercritical carbon dioxide fluid with vacuum inside the mold cavity.

  2. Two component tungsten powder injection molding – An effective mass production process

    International Nuclear Information System (INIS)

    Antusch, Steffen; Commin, Lorelei; Mueller, Marcus; Piotter, Volker; Weingaertner, Tobias

    2014-01-01

    Tungsten and tungsten-alloys are presently considered to be the most promising materials for plasma facing components for future fusion power plants. The Karlsruhe Institute of Technology (KIT) divertor design concept for the future DEMO power plant is based on modular He-cooled finger units and the development of suitable mass production methods for such parts was needed. A time and cost effective near-net-shape forming process with the advantage of shape complexity, material utilization and high final density is Powder Injection Molding (PIM). This process allows also the joining of two different materials e.g. tungsten with a doped tungsten alloy, without brazing. The complete technological process of 2-Component powder injection molding for tungsten materials and its application on producing real DEMO divertor parts, characterization results of the finished parts e.g. microstructure, hardness, density and joining zone quality are discussed in this contribution

  3. Rapid detection of milk adulteration using intact protein flow injection mass spectrometric fingerprints combined with chemometrics.

    Science.gov (United States)

    Du, Lijuan; Lu, Weiying; Cai, Zhenzhen Julia; Bao, Lei; Hartmann, Christoph; Gao, Boyan; Yu, Liangli Lucy

    2018-02-01

    Flow injection mass spectrometry (FIMS) combined with chemometrics was evaluated for rapidly detecting economically motivated adulteration (EMA) of milk. Twenty-two pure milk and thirty-five counterparts adulterated with soybean, pea, and whey protein isolates at 0.5, 1, 3, 5, and 10% (w/w) levels were analyzed. The principal component analysis (PCA), partial least-squares-discriminant analysis (PLS-DA), and support vector machine (SVM) classification models indicated that the adulterated milks could successfully be classified from the pure milks. FIMS combined with chemometrics might be an effective method to detect possible EMA in milk. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Isotope analysis of U using surface ionization mass spectrometry

    International Nuclear Information System (INIS)

    Cesario, Jean

    Surface ionization mass spectrometry is a good technique for the determination of U isotope concentrations. The principles of the method are described: ionization, optical systems, measuring systems. The sensitivity and accuracy of the method are presented [fr

  5. Effect of injection molded micro-structured polystyrene surfaces on proliferation of MC3T3-E1 cells

    Directory of Open Access Journals (Sweden)

    G. Lucchetta

    2015-04-01

    Full Text Available In this work, osteoinductive micro-pillared polystyrene surfaces were mass-produced for bone replacement applications, by means of the micro injection molding process. Firstly, the molding process parameters were optimized with a two-level, three-factor central composite face-centered plan to increase the quality of polystyrene micro pillars replication and to maximize the pillars height uniformity over the molded part. Secondly, osteoblastic MC3T3-E1 cells adhesion and proliferation on the replicated substrates were assessed as a function of micro topography parameters, such as pillars diameter, aspect ratio and spacing. Cell morphology and proliferation were evaluated through MTS test after 1, 3 and 7 days from seeding. The experimental results showed that cells adhesion and proliferation is more positively promoted on micro-pillared surfaces compared to flat surfaces, but no correlations were observed between cell proliferation and pillar diameter and spacing.

  6. Under pressure: progressively enlarging facial mass following high-pressure paint injection injury.

    Science.gov (United States)

    Mushtaq, Jameel; Walker, Abigail; Hunter, Ben

    2016-01-19

    High-pressure paint injection injuries are relatively rare industrial accidents and almost exclusively occur on the non-dominant hand. A rarely documented complication of these injuries is the formation of a foreign body granuloma. We report a case of a 33-year-old man presenting with extensive facial scarring and progressive right paranasal swelling 7 years after a high-pressure paint injury. After imaging investigations, an excision of the mass and revision of scarring was performed. Access to the mass was gained indirectly through existing scarring over the nose to ensure an aesthetic result. Histological analysis revealed a florid granulomatous foreign body reaction to retained paint. To the best of our knowledge, this is the first reported case of a facial high-pressure paint injury with consequent formation of a foreign body granuloma. 2016 BMJ Publishing Group Ltd.

  7. Cavitating flow control through continuous tangential mass injection on a 2D hydrofoil at a small attack angle

    Directory of Open Access Journals (Sweden)

    Timoshevskiy Mikhail V.

    2016-01-01

    Full Text Available We studied cavitating flow over the suction side of a symmetric 2D foil – a scaled-down model of high-pressure hydroturbine guide vanes (GV – in different cavitation regimes at the attack angle of 3°. High-speed imaging was used to analyze spatial patterns and time dynamics of the gas-vapour cavities. A hydroacoustic pressure transducer was employed to register time-spectra of pressure fluctuations nearby the hydrofoil. A PIV technique was applied to measure the velocity fields and its fluctuations. The active flow control was implemented by means of a continuous liquid supply with different flow rates through a slot channel located in the GV surface. It was found that the active mass injection does not influence the primary flow upstream of the slot channel position. For the cavitation-free and cavitation inception cases, the injection was shown to make the turbulent wake past the GV section more intense. However, at the developed cavitation regimes the active flow management made it possible to reduce substantially the amplitude or even totally suppress the periodic cavity length oscillations and pressure pulsations associated with them.

  8. Use of flow injection mass spectrometric fingerprinting and chemometrics for differentiation of three black cohosh species

    International Nuclear Information System (INIS)

    Huang, Huilian; Sun, Jianghao; McCoy, Joe-Ann; Zhong, Haiyan; Fletcher, Edward J.; Harnly, James; Chen, Pei

    2015-01-01

    Flow injection mass spectrometry (FIMS) was used to provide chemical fingerprints of black cohosh (Actaea racemosa L.) in a manner of minutes by omitting the separation step. This method has proven to be a powerful tool for botanical authentication and in this study it was used to distinguish between three Actaea species prior to a more detailed chemical analysis using ultra high-performance liquid chromatography high-resolution mass spectrometry (UHPLC–HRMS). Black cohosh has become increasingly popular as a dietary supplement in the United States for the treatment of symptoms related to menopause. However, it has been known to be adulterated with the Asian Actaea dahurica (Turcz. ex Fisch. & C.A.Mey.) Franch. species (syn. Cimicifuga dahurica (Turcz.) Maxim). Existing methods for identification of black cohosh and differentiation of Actaea species are usually lengthy, laborious, and lack robustness, often based on the comparison of a few pre-selected components. Chemical fingerprints were obtained for 77 black cohosh samples and their related species using FIMS in the negative ion mode. The analysis time for each sample was less than 2 min. All data were processed using principal component analysis (PCA). FIMS fingerprints could readily differentiate all three species. Representative samples from each of the three species were further examined using UHPLC–MS to provide detailed profiles of the chemical differences between the three species and were compared to the PCA loadings. This study demonstrates a simple, fast, and easy analytical method that can be used to differentiate A. racemosa, Actaea podocarpa, and A. dahurica. - Highlights: • Flow injection mass spectrometry (FIMS) was used to provide chemical fingerprints of black cohosh (Actaea racemosa L.) in a manner of minutes by omitting the separation step. • FIMS can discriminate between A. dahurica, A. podocarpa, and A. racemosa. • FIMS is a valuable screening tool for authentication of botanicals

  9. Use of flow injection mass spectrometric fingerprinting and chemometrics for differentiation of three black cohosh species

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Huilian [Food Composition and Methods Development Laboratory, Beltsville Human Nutrition Research Center, Agricultural Research Service, U.S. Department of Agriculture, Beltsville, MD (United States); Key Laboratory of Modern Preparation of TCM, Jiangxi University of Traditional Chinese Medicine, Ministry of Education, Nanchang, Jiangxi Province (China); Sun, Jianghao [Food Composition and Methods Development Laboratory, Beltsville Human Nutrition Research Center, Agricultural Research Service, U.S. Department of Agriculture, Beltsville, MD (United States); McCoy, Joe-Ann [The North Carolina Arboretum Germplasm Repository, UNC Affiliate Campus, Asheville, NC (United States); Zhong, Haiyan [College of Food Science and Engineering, Central South University of Forestry and Technology, Changsha, Hunan Province (China); Fletcher, Edward J. [Strategic Sourcing, Inc., Banner Elk, NC 28604 (United States); Harnly, James, E-mail: harnly.james@ars.usda.gov [Food Composition and Methods Development Laboratory, Beltsville Human Nutrition Research Center, Agricultural Research Service, U.S. Department of Agriculture, Beltsville, MD (United States); Chen, Pei, E-mail: pei.chen@ars.usda.gov [Food Composition and Methods Development Laboratory, Beltsville Human Nutrition Research Center, Agricultural Research Service, U.S. Department of Agriculture, Beltsville, MD (United States)

    2015-03-01

    Flow injection mass spectrometry (FIMS) was used to provide chemical fingerprints of black cohosh (Actaea racemosa L.) in a manner of minutes by omitting the separation step. This method has proven to be a powerful tool for botanical authentication and in this study it was used to distinguish between three Actaea species prior to a more detailed chemical analysis using ultra high-performance liquid chromatography high-resolution mass spectrometry (UHPLC–HRMS). Black cohosh has become increasingly popular as a dietary supplement in the United States for the treatment of symptoms related to menopause. However, it has been known to be adulterated with the Asian Actaea dahurica (Turcz. ex Fisch. & C.A.Mey.) Franch. species (syn. Cimicifuga dahurica (Turcz.) Maxim). Existing methods for identification of black cohosh and differentiation of Actaea species are usually lengthy, laborious, and lack robustness, often based on the comparison of a few pre-selected components. Chemical fingerprints were obtained for 77 black cohosh samples and their related species using FIMS in the negative ion mode. The analysis time for each sample was less than 2 min. All data were processed using principal component analysis (PCA). FIMS fingerprints could readily differentiate all three species. Representative samples from each of the three species were further examined using UHPLC–MS to provide detailed profiles of the chemical differences between the three species and were compared to the PCA loadings. This study demonstrates a simple, fast, and easy analytical method that can be used to differentiate A. racemosa, Actaea podocarpa, and A. dahurica. - Highlights: • Flow injection mass spectrometry (FIMS) was used to provide chemical fingerprints of black cohosh (Actaea racemosa L.) in a manner of minutes by omitting the separation step. • FIMS can discriminate between A. dahurica, A. podocarpa, and A. racemosa. • FIMS is a valuable screening tool for authentication of botanicals.

  10. Injection molded superhydrophobic surfaces based on microlithography and black silicon processing

    DEFF Research Database (Denmark)

    Søgaard, Emil; Andersen, Nis Korsgaard; Taboryski, Rafael

    2012-01-01

    This work is concerned with the design, development, and testing of nanostructured polymer surfaces with self-cleaning properties that can be manufactured by injection molding. In particular, the superimposed micro- and nanometer length scales of the so-called Lotus effect were investigated...

  11. SUSTAINED HYPERLIPEMIA INDUCED IN RABBITS BY MEANS OF INTRAVENOUSLY INJECTED SURFACE-ACTIVE AGENTS

    Science.gov (United States)

    Kellner, Aaron; Correll, James W.; Ladd, Anthony T.

    1951-01-01

    The intravenous injection of the surface-active agents Tween 80 and Triton A20 into rabbits fed a normal diet resulted in marked and sustained elevations of the cholesterol, phospholipid, and total lipid content of their blood. The increase in phospholipid in general paralleled that of the blood cholesterol. The implications of the findings are briefly discussed. PMID:14824409

  12. Injection molding of nanopatterned surfaces in the sub-micrometer range with induction heating aid

    DEFF Research Database (Denmark)

    Menotti, Stefano; Hansen, Hans Nørgaard; Bissacco, Giuliano

    2014-01-01

    Replication of sub-micrometer structures by injection molding leads to special requirements for the mold in order to ensure proper replica and acceptable cycle time. This paper investigates the applicability of induction heating embedded into the mold for the improvement of nanopattern replication...... as materials, and heating parameters were investigated after a preliminary optimization with standard heating conditions. The replicated surfaces were quantitatively characterized by atomic force microscopy using specific three-dimensional surface amplitude parameters and qualitatively inspected by scanning...

  13. Determination of phosphodiesterase type V inhibitors in wastewater by direct injection followed by liquid chromatography coupled to tandem mass spectrometry

    NARCIS (Netherlands)

    Causanilles, A.; Emke, E.; de Voogt, P.

    2016-01-01

    A simple, fast and reliable analytical method for the determination of phosphodiesterase type V inhibitors in wastewater was developed and validated. The method was based on direct injection followed by liquid chromatography coupled to tandem mass spectrometry with triple quadrupole as mass

  14. Gravitational lensing by a smoothly variable surface mass density

    Science.gov (United States)

    Paczynski, Bohdan; Wambsganss, Joachim

    1989-01-01

    The statistical properties of gravitational lensing due to smooth but nonuniform distributions of matter are considered. It is found that a majority of triple images had a parity characteristic for 'shear-induced' lensing. Almost all cases of triple or multiple imaging were associated with large surface density enhancements, and lensing objects were present between the images. Thus, the observed gravitational lens candidates for which no lensing object has been detected between the images are unlikely to be a result of asymmetric distribution of mass external to the image circle. In a model with smoothly variable surface mass density, moderately and highly amplified images tended to be single rather than multiple. An opposite trend was found in models which had singularities in the surface mass distribution.

  15. Injection molded superhydrophobic surfaces based on microlithography and black silicon processing

    DEFF Research Database (Denmark)

    Søgaard, Emil; Andersen, Nis Korsgaard; Taboryski, Rafael

    2012-01-01

    This work is concerned with the design, development, and testing of nanostructured polymer surfaces with self-cleaning properties that can be manufactured by injection molding. In particular, the superimposed micro- and nanometer length scales of the so-called Lotus effect were investigated...... in detail with an engineering perspective on choice of materials and manufacturability by injection molding. Microscope slides with superhydrophobic properties were succesfully fabricated. Preliminary results indicate a contact angle increase from 95° for the unstructured polymer to a maximum 150...

  16. Filterless preconcentration, flow injection analysis and detection by inductively-coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov

    The influence of interferences in the analysis of elements by inductively-coupled-plasma mass-spectrometry (ICP-MS) may be significantly diminished by utilising a protocol of flow-injection analysis (FIA). The method is based on filterless preconcentration of metallic elements at the walls...... of a knotted reactor that was made of nylon tubings. In the load mode, the preconcentration was accomplished by precipitation of metallic species in alkaline-buffered carriers onto the inner walls of the hydrofilic tube. After a preconcen-tration period of 40-120 seconds using sample volumes of 4-10 m...... of 10-30 were obtained in the analysis of aluminium, of chromium and of iron, which resulted in detection limits (3) down to 20 g/L at a sampling frequency of 50 per hour. The preconcentration protocol improves the selectivity thus allowing direct determination of the elements in saline media. Anionic...

  17. Mass loading of soil particles on plant surfaces

    International Nuclear Information System (INIS)

    Pinder, J.E. III; McLeod, K.W.

    1989-01-01

    Radionuclide-bearing soil particles on plant surfaces can be ingested and contribute to human dose, but evaluating the potential dose is limited by the relatively few data available on the masses of soil particles present on plant surfaces. This report summarizes mass loading data (i.e., mass of soil per unit of vegetation) for crops in the southeastern United States and compares these data to (1) those from other regions and (2) the mass loadings used in radionuclide transfer models to predict soil contamination of plant surfaces. Mass loadings were estimated using the 238Pu content of crops as an indicator of soil on plant surfaces. Crops were grown in two soils: a sandy clay loam soil and a loamy sand soil. Concentrations of soil on southeastern crops (i.e., mg soil g-1 plant) differed by more than a factor of 100 due to differences in crop growth form and biomass. Mean concentrations ranged from 1.7 mg g-1 for corn to 260 mg g-1 for lettuce. Differences in mass loadings between soils were less than those among crops. Concentrations differed by less than a factor of two between the two soil types. Because of (1) the differences among crops and (2) the limited data available from other systems, it is difficult to draw conclusions regarding regional or climatic variation in mass loadings. There is, however, little evidence to suggest large differences among regions. The mass loadings used to predict soil contamination in current radionuclide transfer models appear to be less than those observed for most crops

  18. Trace analysis of isothiazolinones in water samples by large-volume direct injection liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Speksnijder, P; van Ravestijn, J; de Voogt, P

    2010-08-06

    Isothiazolinones are used as preservatives, biocides and disinfectants in a variety of industrial and domestic applications. Some of the isothiazolinones are difficult to isolate from water due their high polarity. A sensitive and selective analytical method was developed and optimized for the determination of sub-microg/L levels of three isothiazolinones in water samples. Three isothiazolinones are described in this paper: 2-methyl-3-isothiazolinone, 5-chloro-2-methyl-3-isothiazolinone and 4,5-dichloro-2-methyl-3-isothiazolinone. The analytical method involves a robust large-volume direct on-column loop injection of 2 mL on an Aqua ODS HPLC column and tandem MS detection (HPLC-MS/MS). After filtration, samples are directly injected without further pretreatment. Detection limits of the individual target compounds were between 0.03 and 0.1 microg/L employing Multi-Reaction Monitoring (MRM) mass spectrometry. Based on the constant ratio of two selected product-ions together with the retention time, the identification is very selective and quantification is reliable. The method was successfully applied to real samples of membrane flushings, drinking water, surface waters and waste water. Additional investigations showed the instability of the isothiazolinones in river- and waste water. Preservation of river water and waste water samples with sodium azide (NaN(3)) promotes the stability of the isothiazolines in solution. In membrane flushings, waste water, surface waters and drinking water, levels of the three isothiazolinones were all below the limit of detection. In effluents of households containing washings from normal shampoo use, isothiazolinones could be detected. Copyright 2010 Elsevier B.V. All rights reserved.

  19. On-ground testing of the role of adhesion in the LISA-Pathfinder test mass injection phase

    Science.gov (United States)

    Bortoluzzi, D.; Zanoni, C.; Conklin, J. W.

    2017-05-01

    Many space missions share the need to fly a free-falling body inside the spacecraft, as a reference for navigation and/or as a probe for the local gravitational field. When a mechanism is required to cage such an object during the launch phase, the need arises to release it to free-fall once the operational phase must be initiated in orbit. The criticality of this phase increases when the mechanical interfaces between the body and the mechanism are affected by adhesion and the actuation authority of the control system on the free-falling body is limited. Both conditions are realized in the LISA Pathfinder mission, which aims at injecting a gold-coated 2 kg cubic test mass into a nearly perfect geodesic trajectory to demonstrate the readiness of the developed technology for in-space gravity wave detection. The criticality of adhesion is widely recognized in space technology, because it can affect and jeopardize the functionality of mechanisms, when arising between moving parts. In the LISA Pathfinder case, metallic adhesion potentially plays a relevant role, mainly for two reasons. First, thanks to its properties (ductility, high surface energy) the gold coating on the proof mass easily produces cold weldings, especially in vacuum conditions. Second, the detachment of the proof mass from the releasing device occurs abruptly and a relevant influence of the separation velocity is expected on the strength of the welding. This can produce an excessive velocity of the proof mass at the retraction of the releasing device for the following capture and centring phase on behalf of the control system. A testing activity is performed to characterize the dynamic behaviour of the adhesive bonds between the proof mass and the releasing device, which can be used to predict their contribution on the residual velocity of the proof mass after in-flight release. The study of such a dynamic phenomenon sets some challenging requirements on the measurement technique, both on the

  20. Gold nanorods for surface Plasmon resonance detection of mercury (II) in flow injection analysis.

    Science.gov (United States)

    Trieu, Khang; Heider, Emily C; Brooks, Scott C; Barbosa, Fernando; Campiglia, Andres D

    2014-10-01

    This article investigates the flow injection analysis of mercury (II) ions in tap water samples via surface Plasmon resonance detection. Quantitative analysis of mercury (II) is based on the chemical interaction of metallic mercury with gold nanorods immobilized on a glass substrate. A new flow cell design is presented with the ability to accommodate the detecting substrate in the sample compartment of commercial spectrometers. Two alternatives are here considered for mercury (II) detection, namely stop-flow and continuous flow injection analysis modes. The best limit of detection (2.4 ng mL(-1)) was obtained with the continuous flow injection analysis approach. The accurate determination of mercury (II) ions in samples of unknown composition is demonstrated with a fortified tap water sample. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Nonlinear dynamic behaviors of an optically injected vertical-cavity surface-emitting laser

    International Nuclear Information System (INIS)

    Li Xiaofeng; Pan Wei; Luo Bin; Ma Dong; Wang Yong; Li Nuohan

    2006-01-01

    Nonlinear dynamics of a vertical-cavity surface-emitting laser (VCSEL) with external optical injection are studied numerically. We consider a master-slave configuration where the dynamic characteristics of the slave are affected by the optical injection from the master, and we also establish the corresponding Simulink model. The period-doubling route as well as the period-halving route is observed, where the regular, double-periodic, and chaotic pulsings are found. By adjusting the injection strength properly, the laser can be controlled to work at a given state. The effects of frequency detuning on the nonlinear behaviors are also investigated in terms of the bifurcation diagrams of photon density with the frequency detuning. For weak injection case, the nonlinear dynamics shown by the laser are quite different when the value of frequency detuning varies contrarily (positive and negative direction). If the optical injection is strong enough, the slave can be locked by the master even though the frequency detuning is relatively large

  2. The sensitivity of the surface oil signature to subsurface dispersant injection and weather conditions.

    Science.gov (United States)

    Daae, Ragnhild L; Skancke, Jørgen; Brandvik, Per Johan; Faksness, Liv-Guri

    2018-02-01

    Subsea blowouts have the potential to spread oil across large geographical areas, and subsea dispersant injection (SSDI) is a response option targeted at reducing the impact of a blowout, especially reducing persistent surface oil slicks. Modified Weber scaling was used to predict oil droplet sizes with the OSCAR oil spill model, and to evaluate the surface oil volume and area when using SSDI under different conditions. Generally, SSDI reduces the amount of oil on the surface, and creates wider and thinner surface oil slicks. It was found that the reduction of surface oil area and volume with SSDI was enhanced for higher wind speeds. Overall, given the effect of SSDI on oil volume and weathering, it may be suggested that tar ball formation, requiring thick and weathered oil, could possibly be reduced when SSDI is used. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Injection moulding of plastic parts with laser textured surfaces with optical applications

    Science.gov (United States)

    Pina-Estany, J.; García-Granada, A. A.; Corull-Massana, E.

    2018-05-01

    The purpose of this work is to manufacture micro and nanotextured surfaces on plastic injection moulds with the aim of replicating them and obtaining plastic parts with optical applications. Different patterns are manufactured with nanosecond and femtosecond lasers in order to obtain three different optical applications: (i) homogeneous light diffusion (ii) 1D light directionality and (iii) 2D light directionality. Induction heating is used in the injections in order to improve the textures degree of replication. The steel mould and the plastic parts are analyzed with a confocal/focus variation microscope and with a surface roughness tester. A mock-up and a luminance camera are used to evaluate the homogeneity and luminance of the homogeneous light diffusion application in comparison with the current industrial solutions.

  4. Development of a rapid surface temperature heating system and its application to micro-injection

    OpenAIRE

    Sora, Ricardo Jorge Paredes

    2014-01-01

    Dissertação de mestrado integrado em Polymer Engineering During filling stage, the constant mold temperature control strategy by circling coolant through cooling channels used in conventional injection molding causes an abrupt polymer solidification close to the mold surface and consequently resulting in a frozen layer. As the viscosity increases, the mobility of the polymer to fill the cavity is largely decreased influencing the frozen orientation. This phenomenon affects grea...

  5. The effect of body mass index on fluoroscopy time and radiation dose in intra-articular glenohumeral joint injections.

    Science.gov (United States)

    Mattie, Ryan; McCormick, Zachary L; Fogg, Benjamin; Cushman, Daniel M

    To determine the relationship between body mass index (BMI) and fluoroscopy time and radiation dose during fluoroscopy-guided glenohumeral joint injections. This was a retrospective analysis of prospectively collected data. Physicians with board certification in Physical Medicine and Rehabilitation and/or Sports Medicine performed or supervised all injections. BMI was calculated within three months of the injection. Fluoroscopy time and radiation dose data were recorded by the fluoroscopy system and transcribed into the clinical database after each procedure. A total of 335 intra-articular GHJ injections were performed, 230 on the right shoulder and 105 on the left shoulder; none were bilateral. The mean fluoroscopy time for all injections was 18.8±12.6s, and the mean radiation DAP was 656±1190mGy-cm2. There was no significant difference in fluoroscopy time or dose between first-time and repeat injections (P=.405; P=.011) and no significant differences in fluoroscopy time or radiation dose when a trainee was involved (P=.756 for time and P=.149 for dose). Needle lengths of 1.5, 2.5, or 3.5in. were used during the injection, and there was no significant difference in needle length selection between BMI groups (P=.319). Intra-articular glenohumeral joint injection fluoroscopy time and radiation dose are not affected by body mass index, age, gender, trainee-involvement, first versus repeat injection, or needle length. This procedure is associated with a dose of radiation that likely has minimal to no clinical significance. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Surface topographic characterization for polyamide composite injection molds made of aluminum and copper alloys.

    Science.gov (United States)

    Pereira, A; Hernández, P; Martinez, J; Pérez, J A; Mathia, T G

    2014-01-01

    In order to ensure flexibility and rapid new product development, the mold industry made use of soft materials for cavity inserts in injection molds. However, materials of this kind are prone to wear. This article analyzes the topographic characterization of the surface and wear processes in injection molds cavities. Two materials have been used to produce the cavities: aluminum alloy EN AW‐6082 T4 and copper alloy Cu Zn39 Pb3. The surface topography was measured with the use of optical interferometry profiling technology; roughness and surface parameters were determined according to ISO 4287, ISO 25178, and EUR 15178N. In order to complete this research, an experimental part with different thicknesses and shapes was designed, and cavity inserts of aluminum and copper were made. Polyamide PA6, with 30% fiberglass reinforcement, was employed in the experimental procedure. Measurements of cavity mold surfaces were performed after 9,200 cycles on each mold and at different locations on the mold. The surface measurement was made with a white light vertical scanning interferometry, also known as coherence scanning interferometry (ISO DIS 25178‐604). The results are analyzed and differences between the two types of cavity inserts materials are discussed. © Wiley Periodicals, Inc.

  7. Surface self-potential patterns related to transmissive fracture trends during a water injection test

    Science.gov (United States)

    DesRoches, A. J.; Butler, K. E.; MacQuarrie, K. TB

    2018-03-01

    Variations in self-potential (SP) signals were recorded over an electrode array during a constant head injection test in a fractured bedrock aquifer. Water was injected into a 2.2 m interval isolated between two inflatable packers at 44 m depth in a vertical well. Negative SP responses were recorded on surface corresponding to the start of the injection period with strongest magnitudes recorded in electrodes nearest the well. SP response decreased in magnitude at electrodes further from the well. Deflation of the packer system resulted in a strong reversal in the SP signal. Anomalous SP patterns observed at surface at steady state were found to be aligned with dominant fracture strike orientations found within the test interval. Numerical modelling of fluid and current flow within a simplified fracture network showed that azimuthal patterns in SP are mainly controlled by transmissive fracture orientations. The strongest SP gradients occur parallel to hydraulic gradients associated with water flowing out of the transmissive fractures into the tighter matrix and other less permeable cross-cutting fractures. Sensitivity studies indicate that increasing fracture frequency near the well increases the SP magnitude and enhances the SP anomaly parallel to the transmissive set. Decreasing the length of the transmissive fractures leads to more fluid flow into the matrix and into cross-cutting fractures proximal to the well, resulting in a more circular and higher magnitude SP anomaly. Results from the field experiment and modelling provide evidence that surface-based SP monitoring during constant head injection tests has the ability to identify groundwater flow pathways within a fractured bedrock aquifer.

  8. Influence of Mold Surface Treatments on Flow of Polymer in Injection Moulding. Application to Weldlines

    Science.gov (United States)

    Chailly, M.; Charmeau, J.-Y.; Bereaux, Y.; Monasse, B.

    2007-04-01

    Due to increasing expectations from the market, the aspect of molded parts has to be improved constantly. Some of the defects observed on these parts such as weldlines are related to the filling stage. To limit this, we investigated the influence on weldlines using various surface deposits on the mold surface, mainly PVD and PACVD deposits : Chromium nitride (CrN), Titanium nitride (TiN), Diamond like Carbon (DLC), Chromium and polished steel (PG) on an instrumented plate mold. Injection campaign was led on three polymers which differ in terms of nature (amorphous, semi-crystalline, copolymers). We studied the evolution of the dimensions of weldlines appearing on the plate using the same injection parameters for a given polymer, but with various deposits and thicknesses. Another aspect that had been investigated is the morphology of the weldline through the thickness of the part, depending on polymer nature. Adhesion of polymer at the flow front with the mold surface proved to change. The modification of the initial contact in the filling stage and thus the thermal resistance at the mold implied a change in the process, increasing or reducing the pressure loss in the flow and differential shrinkage in the final part. The induced impact on dimensions of the weldlines allowed to distinguish which surface treatments were able to reduce the defect. A complementary study was led on both polymers in molten state and deposits in terms of wetting using a sessile drop method to confirm the adhesion at the polymer/mold interface. This study proved the influence of the use of surface treatments has clearly an impact on the filling stage of the injection molding process, and it is necessary to get a better knowledge of the interactions between physical adhesion, tribology of polymer/mold contact, and thermal properties of the coatings and their impact on solidification of the polymer.

  9. Numerical study of surface water waves generated by mass movement

    Energy Technology Data Exchange (ETDEWEB)

    Ghozlani, Belgacem; Hafsia, Zouhaier; Maalel, Khlifa, E-mail: ghozlanib@yahoo.fr [Ecole Nationale d' Ingenieurs de Tunis, Laboratoire de Modelisation en ' Hydraulique et Environnement, BP 37, Le Belvedere, 1002 Tunis (Tunisia)

    2013-10-01

    In this paper waves generated by two-dimensional mass movement are simulated using a numerical model based on the full hydrodynamic coupling between rigid-body motion and ambient fluid flow. This approach has the capability to represent the dynamics of the moving rigid body, which avoids the need to prescribe the body velocity based on the data measurements. This model is implemented in the CFX code and uses the Reynolds average Navier-Stokes equations solver coupled to the recently developed immersed solid technique. The latter technique allows us to follow implicitly the motion of the solid block based on the rigid body solver. The volume-of-fluid method is used to track the free surface locations. The accuracy of the present model is firstly examined against the simple physical case of a freely falling rigid body into water reproducing Scott Russell's solitary waves. More complex and realistic simulations of aerial and submarine mass-movement, simulated by a rigid wedge sliding into water along a 45 Degree-Sign slope, are then performed. Simulated results of the aerial mass movement show the complex flow patterns in terms of the velocity fields and free surface profiles. Results are in good agreement with the available experimental data. In addition, the physical processes associated with the generation of water wave by two-dimensional submarine mass-movement are explored. The effects of the initial submergence and specific gravity on the slide mass kinematics and maximum wave amplitude are investigated. The terminal velocity and initial acceleration of the slide mass are well predicted when compared to experimental results. It is found that the initial submergence did not have a significant effect on the initial acceleration of the slide block centre of mass. However, it depends nonlinearly on the specific gravity. The maximum wave amplitude and the time at which it occurred are also presented as a function of the initial submergence and specific gravity

  10. Use of flow injection mass spectrometric fingerprinting and chemometrics for differentiation of three black cohosh species

    Science.gov (United States)

    Huang, Huilian; Sun, Jianghao; McCoy, Joe-Ann; Zhong, Haiyan; Fletcher, Edward J.; Harnly, James; Chen, Pei

    2015-03-01

    Flow injection mass spectrometry (FIMS) was used to provide chemical fingerprints of black cohosh (Actaea racemosa L.) in a manner of minutes by omitting the separation step. This method has proven to be a powerful tool for botanical authentication and in this study it was used to distinguish between three Actaea species prior to a more detailed chemical analysis using ultra high-performance liquid chromatography high-resolution mass spectrometry (UHPLC-HRMS). Black cohosh has become increasingly popular as a dietary supplement in the United States for the treatment of symptoms related to menopause. However, it has been known to be adulterated with the Asian Actaea dahurica (Turcz. ex Fisch. & C.A.Mey.) Franch. species (syn. Cimicifuga dahurica (Turcz.) Maxim). Existing methods for identification of black cohosh and differentiation of Actaea species are usually lengthy, laborious, and lack robustness, often based on the comparison of a few pre-selected components. Chemical fingerprints were obtained for 77 black cohosh samples and their related species using FIMS in the negative ion mode. The analysis time for each sample was less than 2 min. All data were processed using principal component analysis (PCA). FIMS fingerprints could readily differentiate all three species. Representative samples from each of the three species were further examined using UHPLC-MS to provide detailed profiles of the chemical differences between the three species and were compared to the PCA loadings. This study demonstrates a simple, fast, and easy analytical method that can be used to differentiate A. racemosa, Actaea podocarpa, and A. dahurica.

  11. Mass spectrometric confirmation criterion for product-ion spectra generated in flow-injection analysis. Environmental application

    NARCIS (Netherlands)

    Geerdink, R.B.; Niessen, W.M.A.; Brinkman, U.A.T.

    2001-01-01

    The suitability of a confirmation criterion recently recommended in the Netherlands for gas chromatography with mass spectrometric detection (GC-MS), was evaluated for flow-injection analysis (FIA) with atmospheric pressure chemical ionisation MS-MS detection. The main feature of the criterion is

  12. On the adsorbed mass of polymers on surfaces (NOTE

    Directory of Open Access Journals (Sweden)

    GEORGIOS K. STRATOURAS

    2001-06-01

    Full Text Available It is shown that for ideal polymers interacting with a surface via the pseudopotential of a delta function, the number of contacts between the monomer units and the surface as a function of concentration cb is a dependence of the form acb/(1–bcb. The architecture of the polymer, the degree of polymerization, the interaction energy between a monomer unit and the surface, the area of the surface and the monomer length are embodied in the parameters a and b. The above dependence of the adsorbed mass of a polymer on the concentration is confirmed by the experimental results of Takahashi and his collaborators. For linear polystyrene of molecular weight 134×105,interacting with a chrome plate, the parameters a and b are, respectively, about equal to (89938/273 ×10-6 m and (–19300/273 m3 kg-1.

  13. Powder Injection Molding for mass production of He-cooled divertor parts

    International Nuclear Information System (INIS)

    Antusch, S.; Norajitra, P.; Piotter, V.; Ritzhaupt-Kleissl, H.-J.

    2011-01-01

    A He-cooled divertor for future fusion power plants has been developed at KIT. Tungsten and tungsten alloys are presently considered the most promising materials for functional and structural divertor components. The advantages of tungsten materials lie, e.g. in the high melting point, and low activation, the disadvantages are high hardness and brittleness. The machinig of tungsten, e.g. milling, is very complex and cost-intensive. Powder Injection Molding (PIM) is a method for cost effective mass production of near-net-shape parts with high precision. The complete W-PIM process route is outlined and, results of product examination discussed. A binary tungsten powder feedstock with a grain size distribution in the range 0.7-1.7 μm FSSS, and a solid load of 50 vol.% was developed. After heat treatment, the successfully finished samples showed promising results, i.e. 97.6% theoretical density, a grain size of approximately 5 μm, and a hardness of 457 HV0.1.

  14. Determination of injection molding process windows for optical lenses using response surface methodology.

    Science.gov (United States)

    Tsai, Kuo-Ming; Wang, He-Yi

    2014-08-20

    This study focuses on injection molding process window determination for obtaining optimal imaging optical properties, astigmatism, coma, and spherical aberration using plastic lenses. The Taguchi experimental method was first used to identify the optimized combination of parameters and significant factors affecting the imaging optical properties of the lens. Full factorial experiments were then implemented based on the significant factors to build the response surface models. The injection molding process windows for lenses with optimized optical properties were determined based on the surface models, and confirmation experiments were performed to verify their validity. The results indicated that the significant factors affecting the optical properties of lenses are mold temperature, melt temperature, and cooling time. According to experimental data for the significant factors, the oblique ovals for different optical properties on the injection molding process windows based on melt temperature and cooling time can be obtained using the curve fitting approach. The confirmation experiments revealed that the average errors for astigmatism, coma, and spherical aberration are 3.44%, 5.62%, and 5.69%, respectively. The results indicated that the process windows proposed are highly reliable.

  15. Ellipsoidal Correction in GRACE Surface Mass Change Estimation

    Science.gov (United States)

    Li, Jin; Chen, Jianli; Li, Ziang; Wang, Song-Yun; Hu, Xiaogong

    2017-11-01

    The Earth's shape is much closer to an ellipsoid than a sphere. The commonly used spherical approximation in mass change inversion is expected to cause bias by the spherical harmonic (SH) solutions from Gravity Recovery and Climate Experiment (GRACE), especially in high-latitude regions where significant present-day ice losses occur. This bias, or ellipsoidal correction, reaches up to 8% from the evaluation by simulations based on synthetic mass change rate models. Further evaluation using 14 plus years of GRACE monthly SH solutions (from April 2002 to December 2016) indicates that the ellipsoidal correction is also noticeable in the total mass change time series over polar regions. Before and after the ellipsoidal correction, the estimated linear rates from mass change time series differ by 4.3%, 4.7%, 5.2%, 5.7%, and 6.6% for five selected regions over Greenland, Antarctic Peninsula, Amundsen Sea Embayment, Alaska glacier, and Svalbard Islands, respectively. Although with amplitudes likely below the current GRACE's uncertainty level, these differences are consistently negative over the five regions. This indicates that the spherical approximation leads to systematic underestimation for polar mass change rates. Thus, the ellipsoidal correction needs to be considered for more precise mass recovery with GRACE SH solutions. It also depends on spatial scales of mass change signals (the smaller the spatial scale, the larger the correction). To more reliably estimate high-latitude surface mass changes by GRACE SH solutions, the ellipsoidal correction is recommended, especially for ice-loss signals over polar regions.

  16. The Shrinkage Behavior and Surface Topographical Investigation for Micro Metal Injection Molding

    DEFF Research Database (Denmark)

    Islam, Aminul; Giannekas, Nikolaos; Marhöfer, David Maximilian

    2014-01-01

    Metal injection molding (MIM) is a near net shape manufacturing technology that can produce highly complex and dimensionally stable parts for high end engineering applications. Despite the recent growth and industrial interest, micro metal molding is yet to be the field of extensive research...... especially when it is compared with micro molding of thermoplastics. The current paper presents a thorough investigation on the process of metal injection molding where it systematically characterizes the effects of important process conditions on the shrinkage and surface quality of molded parts with micro...... features. Effects of geometrical factors like feature dimensions and distance from the gate on the replication quality are studied. The influence of process conditions on the achievable roughness for the final metal parts is discussed based on the experimental findings. The test geometry is characterized...

  17. SBAS Analysis of Induced Ground Surface Deformation from Wastewater Injection in East Central Oklahoma, USA

    Directory of Open Access Journals (Sweden)

    Elizabeth Loesch

    2018-02-01

    Full Text Available The state of Oklahoma has experienced a dramatic increase in the amount of measurable seismic activities over the last decade. The needs of a petroleum-driven world have led to increased production utilizing various technologies to reach energy reserves locked in tight formations and stimulate end-of-life wells, creating significant amounts of undesirable wastewater ultimately injected underground for disposal. Using Phased Array L-band Synthetic Aperture Radar (PALSAR data, we performed a differential Synthetic Aperture Radar Interferometry (InSAR technique referred to as the Small BAseline Subset (SBAS-based analysis over east central Oklahoma to identify ground surface deformation with respect to the location of wastewater injection wells for the period of December 2006 to January 2011. Our results show broad spatial correlation between SBAS-derived deformation and the locations of injection wells. We also observed significant uplift over Cushing, Oklahoma, the largest above ground crude oil storage facility in the world, and a key hub of the Keystone Pipeline. This finding has significant implications for the oil and gas industry due to its close proximity to the zones of increased seismicity attributed to wastewater injection. Results southeast of Drumright, Oklahoma represent an excellent example of the potential of InSAR, identifying a fault bordered by an area of subduction to the west and uplift to the east. This differentiated movement along the fault may help explain the lack of any seismic activity in this area, despite the large number of wells and high volume of fluid injected.

  18. Optical Injection Locking of Vertical Cavity Surface-Emitting Lasers: Digital and Analog Applications

    Science.gov (United States)

    Parekh, Devang

    With the rise of mobile (cellphones, tablets, notebooks, etc.) and broadband wireline communications (Fiber to the Home), there are increasing demands being placed on transmitters for moving data from device to device and around the world. Digital and analog fiber-optic communications have been the key technology to meet this challenge, ushering in ubiquitous Internet and cable TV over the past 20 years. At the physical layer, high-volume low-cost manufacturing of semiconductor optoelectronic devices has played an integral role in allowing for deployment of high-speed communication links. In particular, vertical cavity surface emitting lasers (VCSEL) have revolutionized short reach communications and are poised to enter more markets due to their low cost, small size, and performance. However, VCSELs have disadvantages such as limited modulation performance and large frequency chirp which limits fiber transmission speed and distance, key parameters for many fiber-optic communication systems. Optical injection locking is one method to overcome these limitations without re-engineering the VCSEL at the device level. By locking the frequency and phase of the VCSEL by the direct injection of light from another laser oscillator, improved device performance is achieved in a post-fabrication method. In this dissertation, optical injection locking of VCSELs is investigated from an applications perspective. Optical injection locking of VCSELs can be used as a pathway to reduce complexity, cost, and size of both digital and analog fiber-optic communications. On the digital front, reduction of frequency chirp via bit pattern inversion for large-signal modulation is experimentally demonstrated showing up to 10 times reduction in frequency chirp and over 90 times increase in fiber transmission distance. Based on these results, a new reflection-based interferometric model for optical injection locking was established to explain this phenomenon. On the analog side, the resonance

  19. Coupling sequential injection on-line preconcentration using a PTFE beads packed column to direct injection nebulization inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2002-01-01

    An automated sequential injection on-line preconcentration procedure for trace metals by using a PTFE bead-packed microcolumn coupled to ICP-MS is described, and used for simultaneous analyses of cadmium and lead. In dilute nitric acid (0.5%, v/v), neutral complexes between the analytes and chela......An automated sequential injection on-line preconcentration procedure for trace metals by using a PTFE bead-packed microcolumn coupled to ICP-MS is described, and used for simultaneous analyses of cadmium and lead. In dilute nitric acid (0.5%, v/v), neutral complexes between the analytes...... and chelating reagent, diethyldithiophosphate (DDPA), are formed and adsorbed onto the surface of the PTFE beads. The adsorbed complexes are afterwards eluted with 20% nitric acid and the leading part of the eluate (40 mul) is stored in a sample loop (SL), the contents of which are subsequently transported, via...

  20. Summary report: Assessment of deep injection well associated surface soils at the Idaho National Engineering Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Pole, S.B.

    1993-01-01

    This report summarizes sampling activities and analytical results of the chemical and radiological content of surface soils from storm water retention basins and drainage ditches associated with eight deep injection wells at the Idaho National Engineering Laboratory. The results of the sampling effort were intended to support permitting of the injection wells by the State of Idaho Department of Water Resources. In August 1992, the surface soils associated with eight storm water retention basins and ditches were sampled. All samples were collected and analyzed in accordance with a written sampling and analysis plan. The samples were analyzed by an off-Site contract laboratory, and the results were compared to local and regional soil analytical data to determine the presence of contaminants. The results indicated that the surface soils from the storm water retention basins and ditches did not have concentrations of metals or radionuclides greater than the range of concentrations found in local and regional soils. Volatile organic compounds were below detection limits.

  1. Evaluation of optical functional surfaces on the injection moulding insert by micro milling process

    DEFF Research Database (Denmark)

    Li, Dongya; Davoudinejad, Ali; Zhang, Yang

    2017-01-01

    This study presents the optimization of micro milling process for manufacturing injection moulding inserts with an optical functionalsurface. The objective is the optimal surface functionality. Micro ridges were used as the microstructures to realize the function to generate contrast between...... orthogonally textured areas by reflecting light in different directions. In order to maximize the contrast,a sample was machined with the same structures and dimensions, according to a Design of Experiments (DOEs) to optimize the milling parameters by considering the contrast as a response. The contrast...

  2. In vitro bioactivity of micro metal injection moulded stainless steel with defined surface features

    Directory of Open Access Journals (Sweden)

    C Brose

    2012-05-01

    Full Text Available Micrometre- and nanometre-scale surface structuring with ordered topography features may dramatically enhance orthopaedic implant integration. In this study we utilised a previously optimised micron metal injection moulding (µ-MIM process to produce medical grade stainless steel surfaces bearing micrometre scale, protruding, hemispheres of controlled dimensions and spatial distribution. Additionally, the structured surfaces were characterised by the presence of submicrometre surface roughness resulting from metal grain boundary formation. Following cytocompatibility (cytotoxicity evaluation using 3T3 mouse fibroblast cell line, the effect on primary human cell functionality was assessed focusing on cell attachment, shape and cytoskeleton conformation. In this respect, and by day 7 in culture, significant increase in focal adhesion size was associated with the microstructured surfaces compared to the planar control. The morphological conformation of the seeded cells, as revealed by fluorescence cytoskeleton labelling, also appeared to be guided in the vertical dimension between the hemisphere bodies. Quantitative evaluation of this guidance took place using live cytoplasm fluorescence labelling and image morphometry analysis utilising both, compactness and elongation shape descriptors. Significant increase in cell compactness was associated with the hemisphere arrays indicating collective increase in focused cell attachment to the hemisphere bodies across the entire cell population. Micrometre-scale hemisphere array patterns have therefore influenced cell attachment and conformation. Such influence may potentially aid in enhancing key cellular events such as, for example, neo-osteogenesis on implanted orthopaedic surfaces.

  3. Optimisation of warpage on plastic injection moulding part using response surface methodology (RSM) and genetic algorithm method (GA)

    Science.gov (United States)

    Miza, A. T. N. A.; Shayfull, Z.; Nasir, S. M.; Fathullah, M.; Hazwan, M. H. M.

    2017-09-01

    In this study, Computer Aided Engineering was used for injection moulding simulation. The method of Design of experiment (DOE) was utilize according to the Latin Square orthogonal array. The relationship between the injection moulding parameters and warpage were identify based on the experimental data that used. Response Surface Methodology (RSM) was used as to validate the model accuracy. Then, the RSM and GA method were combine as to examine the optimum injection moulding process parameter. Therefore the optimisation of injection moulding is largely improve and the result shown an increasing accuracy and also reliability. The propose method by combining RSM and GA method also contribute in minimising the warpage from occur.

  4. Quantitative Caffeine Analysis Using a Surface Sampling Probe Electrospray Ionization Tandem Mass Spectrometry System

    Energy Technology Data Exchange (ETDEWEB)

    Ford, Michael J [ORNL; Deibel, Michael A. [Earlham College; Tomkins, Bruce A [ORNL; Van Berkel, Gary J [ORNL

    2005-01-01

    Quantitative determination of caffeine on reversed-phase C8 thin-layer chromatography plates using a surface sampling electrospray ionization system with tandem mass spectrometry detection is reported. The thin-layer chromatography/electrospray tandem mass spectrometry method employed a deuterium-labeled caffeine internal standard and selected reaction monitoring detection. Up to nine parallel caffeine bands on a single plate were sampled in a single surface scanning experiment requiring 35 min at a surface scan rate of 44 {mu}m/s. A reversed-phase HPLC/UV caffeine assay was developed in parallel to assess the mass spectrometry method performance. Limits of detection for the HPLC/UV and thin-layer chromatography/electrospray tandem mass spectrometry methods determined from the calibration curve statistics were 0.20 ng injected (0.50 {mu}L) and 1.0 ng spotted on the plate, respectively. Spike recoveries with standards and real samples ranged between 97 and 106% for both methods. The caffeine content of three diet soft drinks (Diet Coke, Diet Cherry Coke, Diet Pepsi) and three diet sport drinks (Diet Turbo Tea, Speed Stack Grape, Speed Stack Fruit Punch) was measured. The HPLC/UV and mass spectrometry determinations were in general agreement, and these values were consistent with the quoted values for two of the three diet colas. In the case of Diet Cherry Coke and the diet sports drinks, the determined caffeine amounts using both methods were consistently higher (by 8% or more) than the literature values.

  5. Cyanide Antidotes for Mass Casualties: Comparison of Intramuscular Injector by Autoinjector, Intraosseous Injection, and Inhalational Delivery

    Science.gov (United States)

    2015-12-01

    Public Release; Distribution Unlimited 13. SUPPLEMENTARY NOTES 14. ABSTRACT Current antidotes for cyanide poisoning must be administered by intravenous... Cyanide Poisoning ; Intramuscular Injection; Intraosseous Injection; Inhalational Delivery 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT...required in cyanide - poisoned victims, since they may be hypotensive with collapsed peripheral veins. Thus, intravenous antidote administration would not

  6. The shrinkage behavior and surface topographical investigation for micro metal injection molding

    Science.gov (United States)

    Islam, A.; Giannekas, N.; Marhöfer, D. M.; Tosello, G.; Hansen, H. N.

    2015-05-01

    Metal injection molding (MIM) is a near net shape manufacturing technology that can produce highly complex and dimensionally stable parts for high end engineering applications. Despite the recent growth and industrial interest, micro metal molding is yet to be the field of extensive research especially when it is compared with micro molding of thermoplastics. The current paper presents a thorough investigation on the process of metal injection molding where it systematically characterizes the effects of important process conditions on the shrinkage and surface quality of molded parts with micro features. Effects of geometrical factors like feature dimensions and distance from the gate on the replication quality are studied. The influence of process conditions on the achievable roughness for the final metal parts is discussed based on the experimental findings. The test geometry is characterized by 2½D surface structures containing thin ribs of different aspect ratios and thicknesses in the sub-mm dimensional range. The test parts were molded from Catamold 316L with a conventional injection molding machine. Afterwards, the parts were de-binded and sintered to produce the final test samples. Among the different process parameters studied, the melt temperature was the most influential parameters for better replication and dimensional stability of the final part. The results presented in the paper clearly show that the shrinkage in metal part is not uniform in the micro scale. It depends on the feature dimensions and also on the process conditions. A thin section of the part exhibits higher relative shrinkage compared with a thicker section. Based on these findings, it can be concluded that a micro part molded by MIM process will have higher relative shrinkage compared to a macro part made with the same process.

  7. The experimental study on the mass transfer model of boron injection for natural circular heating reactor

    International Nuclear Information System (INIS)

    Zha Meisheng; Nie Mengchen; Zhou Huizhong; Wang Liqun; Guo Weiping; Liu ZHiyong

    1989-09-01

    A pulse injection stimulus-response technique to study the boron mixing and transport performance after boron-loaded liquid was injected into the reactor core is described. The experiment was carried out in a simulation device. The simulation medium was used. The experimental results show that the lower plenum where the injection point located can be simplified to one scale inertial unit and the movement of boron mixture was only transported after it had entered into the fuel elements. The definition of boron initiative mixing fraction η is also given. By using relating data a dimensionless equation is obtained

  8. Characterization and analysis of sub-micron surface roughness of injection moulded microfluidic systems using White Light Interferometry

    DEFF Research Database (Denmark)

    Tosello, Guido; Marinello, Francesco; Hansen, Hans Nørgaard

    2009-01-01

    characterization of polymer surfaces. In particular the study considers replication performance of injection moulding applied for the realization of microfluidic systems for blood analysis. Parts were produced by means of a series of statistically designed injection moulding experiments. Three process parameters......Surface topography is of great importance in polymer micro fluidics, therefore the replication capability of the process and the surface quality of the tool has to be suitably optimized. In this paper, optical profilometry (white light interferometry, WLI) is implemented for topographical...... have been controlled: temperature of the melt, temperature of the mould and injection speed. Hybrid tooling was employed for the tool making process and two different types of surfaces were obtained within the micro cavity: a finely finished flat surface (average roughness Ra...

  9. Determination of Parabens by Injection-Port Derivatization Coupled With Gas-Chromatography-Mass Spectrometry and Matrix Solid Phase Dispersion

    Science.gov (United States)

    Djatmika, Rosalina; Ding, Wang-Hsien; Sulistyarti, Hermin

    2018-01-01

    A rapid determination of four parabens preservatives (methyl paraben, ethyl paraben, propyl paraben, and butyl paraben) in marketed seafood is presented. Analytes were extracted and purified using matrix solid-phase dispersion (MSPD) method, followed by Injection port acylation gas chromatography-mass spectrometry (GC-MS) with acetic anhydride reagent. In this method, acylation of parabens was performed by acetic anhydride at GC injection-port generating reduction of the time-consuming sample-processing steps, and the amount of toxic reagents and solvents. The parameters affecting this method such as injection port temperature, purge-off time and acylation (acetic anhydride) volume were studied. In addition, the MSPD influence factors (including the amount of dispersant and clean-up co-sorbent, as well as the volume of elution solvent) were also investigated. After MSPD method and Injection port acylation applied, good linearity of analytes was achieved. The limits of quantitation (LOQs) were 0.2 to 1.0 ng/g (dry weight). Compared with offline derivatization commonly performed, injection port acylation employs a rapid, simple, low-cost and environmental-friendly derivatization process. The optimized method has been successfully applied for the analysis of parabens in four kind of marketed seafood. Preliminary results showed that the total concentrations of four selected parabens ranged from 16.7 to 44.7 ng/g (dry weight).

  10. Partial least-squares-discriminant analysis differentiating Chinese wolfberries by UPLC-MS and flow injection mass spectrometric (FIMS) fingerprints.

    Science.gov (United States)

    Lu, Weiying; Jiang, Qianqian; Shi, Haiming; Niu, Yuge; Gao, Boyan; Yu, Liangli Lucy

    2014-09-17

    Lycium barbarum L. fruits (Chinese wolfberries) were differentiated for their cultivation locations and the cultivars by ultraperformance liquid chromatography coupled with mass spectrometry (UPLC-MS) and flow injection mass spectrometric (FIMS) fingerprinting techniques combined with chemometrics analyses. The partial least-squares-discriminant analysis (PLS-DA) was applied to the data projection and supervised learning with validation. The samples formed clusters in the projected data. The prediction accuracies by PLS-DA with bootstrapped Latin partition validation were greater than 90% for all models. The chemical profiles of Chinese wolfberries were also obtained. The differentiation techniques might be utilized for Chinese wolfberry authentication.

  11. A homemade high-resolution orthogonal-injection time-of-flight mass spectrometer with a heated capillary inlet

    International Nuclear Information System (INIS)

    Guo Changjuan; Huang Zhengxu; Gao Wei; Nian Huiqing; Chen Huayong; Dong Junguo; Shen Guoying; Fu Jiamo; Zhou Zhen

    2008-01-01

    We describe a homemade high-resolution orthogonal-injection time-of-flight (O-TOF) mass spectrometer combing a heated capillary inlet. The O-TOF uses a heated capillary tube combined with a radio-frequency only quadrupole (rf-only quadrupole) as an interface to help the ion transmission from the atmospheric pressure to the low-pressure regions. The principle, configuration of the O-TOF, and the performance of the instrument are introduced in this paper. With electrospray ion source, the performances of the mass resolution, the sensitivity, the mass range, and the mass accuracy are described. We also include our results obtained by coupling atmospheric pressure matrix-assisted laser deporption ionization with this instrument

  12. Lie group analysis for the effect of viscosity and thermophoresis particle deposition on free convective heat and mass transfer in the presence of suction/injection

    Directory of Open Access Journals (Sweden)

    Sivagnana Prabhu K.K.

    2009-01-01

    Full Text Available An analysis has been carried out to study heat and mass transfer characteristics of an incompressible and Newtonian fluid having temperature-dependent fluid viscosity and thermophoresis particle deposition over a vertical stretching surface with variable stream condition. The Rosseland approximation is used to describe the radiative heat flux in the energy equation. The vertical surface is assumed to be permeable so as to allow for possible wall suction or injection. The governing differential equations are derived and transformed using Lie group analysis. The transformed equations are solved numerically by applying Runge-Kutta Gill scheme with shooting technique. Favorable comparisons with previously published work on various special cases of the problem are obtained. Numerical results for the velocity, temperature and concentration profiles for a prescribed temperature-dependent fluid viscosity and thermophoresis particle deposition parameters are presented graphically to elucidate the influence of the various physical parameters.

  13. Surface-ionization field mass-spectrometry studies of nonequilibrium surface ionization

    International Nuclear Information System (INIS)

    Blashenkov, Nikolai M; Lavrent'ev, Gennadii Ya

    2007-01-01

    The ionization of polyatomic molecules on tungsten and tungsten oxide surfaces is considered for quasiequilibrium or essentially nonequilibrium conditions (in the latter case, the term nonequilibrium surface ionization is used for adsorbate ionization). Heterogeneous reactions are supposed to proceed through monomolecular decay of polyatomic molecules or fragments of multimolecular complexes. The nonequilibrium nature of these reactions is established. The dependences of the current density of disordered ions on the surface temperature, electric field strength, and ionized particle energy distribution are obtained in analytical form. Heterogeneous dissociation energies, the ionization potentials of radicals, and the magnitude of reaction departure from equilibrium are determined from experimental data, as are energy exchange times between reaction products and surfaces, the number of molecules in molecular complexes, and the number of effective degrees of freedom in molecules and complexes. In collecting the data a new technique relying on surface-ionization field mass-spectrometry was applied. (instruments and methods of investigation)

  14. A comparison of continuous pneumatic nebulization and flow injection-direct injection nebulization for sample introduction in inductively coupled plasma-mass spectrometry

    International Nuclear Information System (INIS)

    Crain, J.S.; Kiely, J.T.

    1995-08-01

    Dilute nitric acid blanks and solutions containing Ni, Cd, Pb, and U (including two laboratory waste samples) were analyzed eighteen times over a two-month period using inductively coupled plasma-mass spectrometry (ICP-MS). Two different sample introduction techniques were employed: flow injection-direct injection nebulization (FI-DIN) and continuous pneumatic nebulization (CPN). Using comparable instrumental measurement procedures, FI-DIN analyses were 33% faster and generated 52% less waste than CPN analyses. Instrumental limits of detection obtained with FI-DIN and CPN were comparable but not equivalent (except in the case of Pb) because of nebulizer-related differences in sensitivity (i.e., signal per unit analyte concentration) and background. Substantial and statistically significant differences were found between FI-DIN and CPN Ni determinations, and in the case of the laboratory waste samples, there were also small but statistically significant differences between Cd determinations. These small (2 to 3%) differences were not related to polyatomic ion interference (e.g., 95 Mo 16 O + ), but in light of the time savings and waste reduction to be realized, they should not preclude the use of FI-DIN in place of CPN for determination of Cd, Pb, U and chemically

  15. A surface structural model for ferrihydrite I: Sites related to primary charge, molar mass, and mass density

    NARCIS (Netherlands)

    Hiemstra, T.; Riemsdijk, van W.H.

    2009-01-01

    A multisite surface complexation (MUSIC) model for ferrihydrite (Fh) has been developed. The surface structure and composition of Fh nanoparticles are described in relation to ion binding and surface charge development. The site densities of the various reactive surface groups, the molar mass, the

  16. Water injection into vapor- and liquid-dominated reservoirs: Modeling of heat transfer and mass transport

    Energy Technology Data Exchange (ETDEWEB)

    Pruess, K.; Oldenburg, C.; Moridis, G.; Finsterle, S. [Lawrence Berkeley National Lab., CA (United States)

    1997-12-31

    This paper summarizes recent advances in methods for simulating water and tracer injection, and presents illustrative applications to liquid- and vapor-dominated geothermal reservoirs. High-resolution simulations of water injection into heterogeneous, vertical fractures in superheated vapor zones were performed. Injected water was found to move in dendritic patterns, and to experience stronger lateral flow effects than predicted from homogeneous medium models. Higher-order differencing methods were applied to modeling water and tracer injection into liquid-dominated systems. Conventional upstream weighting techniques were shown to be adequate for predicting the migration of thermal fronts, while higher-order methods give far better accuracy for tracer transport. A new fluid property module for the TOUGH2 simulator is described which allows a more accurate description of geofluids, and includes mineral dissolution and precipitation effects with associated porosity and permeability change. Comparisons between numerical simulation predictions and data for laboratory and field injection experiments are summarized. Enhanced simulation capabilities include a new linear solver package for TOUGH2, and inverse modeling techniques for automatic history matching and optimization.

  17. Body mass index and active range of motion exercise treatment after intra-articular injection in adhesive capsulitis.

    Science.gov (United States)

    Lin, Hsi-Hsien; Huang, Tung-Fu; Ma, Hsiao-Li; Liu, Chien-Lin

    2013-04-01

    Adhesive capsulitis is commonly associated with medical diseases such as diabetes mellitus, hyperthyroidism, and obesity. Intra-articular injection has been used to speed recovery and relieve pain associated with frozen shoulder. In this study, we evaluated and compared the effects of an intra-articular injection of corticosteroid and lidocaine in the treatment of primary adhesive capsulitis in overweight and normal-weight patients. This is a prospective clinical study of patients with adhesive capsulitis, in which the main treatment strategy was an intra-articular injection of corticosteroid (3 mL) and lidocaine (3 mL). Active range of motion exercise was initiated immediately after the injection and performed four times daily. The evaluation included the recording of a detailed medical and orthopedic history, and the assessment of pain and function by determining the Constant score at baseline (before injection) and every 2 weeks thereafter. Patients were classified as normal weight (body mass index [BMI] adhesive capsulitis between 2010 and 2012. In the normal-weight group, the mean Constant score increased from 35.4 to 74.6 after 8 weeks, whereas in the overweight group, the mean Constant score increased from 32.0 to 47.2. There was a significant difference in the mean Constant score between the normal-weight and overweight groups at 8 weeks. Active range of motion exercise after an intra-articular injection of corticosteroid and lidocaine improved pain and functional outcome at 8 weeks in normal-weight (BMI adhesive capsulitis. Manipulation under anesthesia may be considered a priority in overweight patients. Copyright © 2013. Published by Elsevier B.V.

  18. Effect of Body Mass Index in Patients Administered Epidural Steroid Injection for Back Pain

    Directory of Open Access Journals (Sweden)

    Pinar Karaca Baysal

    2016-07-01

    Full Text Available Aim: The aim is to investigate the efficacy of epidural steroid injection applied for lumbar discopathy pain to obese and non-obese patients with continuing complaints of back pain, despite the application of medical treatment and physical therapy. Material and Method: The study included 119 patients aged 31-73 years who presented at the Algology Clinic with complaints of back and leg pain which had been ongoing for at least 6 months and with single level disc pathologies, and for whom epidural steroid injection was planned. The patients were separated into 2 groups as obese (BMI >30 and non-obese (BMI

  19. Impact of injection solvent composition on protein identification in column-switching chip-liquid chromatography/mass spectrometry.

    Science.gov (United States)

    Houbart, V; Cobraiville, G; Nys, G; Merville, M-P; Fillet, M

    2016-05-06

    In shotgun proteomics, the gold standard technique is reversed-phase liquid chromatography coupled to mass spectrometry. Many researches have been carried out to study the effects on identification performances of chromatographic parameters such as the stationary phase and column dimensions, mobile phase composition and flow rate, as well as the gradient slope and length. However, little attention is usually paid to the injection solvent composition. In this study, we investigated the effect of the injection solvent on protein identification parameters (number of distinct peptides, amino acid coverage and MS/MS search score) as well as sensitivity. Tryptic peptides from six different proteins, covering a wide range of physicochemical properties, were employed as training set. Design of experiments was employed as a tool to highlight the factors related to the composition of the injection solvent that significantly influenced the obtained results. Optimal results for the training set were applied to analysis of more complex samples. The experiments pointed out optimising the composition of the injection solvent had a strong beneficial effect on all the considered responses. On the basis of these results, an approach to determine optimal conditions was proposed to maximise the protein identification performances and detection sensitivity. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Estimation of the quantification uncertainty from flow injection and liquid chromatography transient signals in inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Laborda, Francisco; Medrano, Jesus; Castillo, Juan R.

    2004-01-01

    The quality of the quantitative results obtained from transient signals in high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICPMS) and flow injection-inductively coupled plasma mass spectrometry (FI-ICPMS) was investigated under multielement conditions. Quantification methods were based on multiple-point calibration by simple and weighted linear regression, and double-point calibration (measurement of the baseline and one standard). An uncertainty model, which includes the main sources of uncertainty from FI-ICPMS and HPLC-ICPMS (signal measurement, sample flow rate and injection volume), was developed to estimate peak area uncertainties and statistical weights used in weighted linear regression. The behaviour of the ICPMS instrument was characterized in order to be considered in the model, concluding that the instrument works as a concentration detector when it is used to monitorize transient signals from flow injection or chromatographic separations. Proper quantification by the three calibration methods was achieved when compared to reference materials, although the double-point calibration allowed to obtain results of the same quality as the multiple-point calibration, shortening the calibration time. Relative expanded uncertainties ranged from 10-20% for concentrations around the LOQ to 5% for concentrations higher than 100 times the LOQ

  1. Isotope dilution-surface ionization mass spectrometry of thallium

    International Nuclear Information System (INIS)

    Murozumi, Masayo; Nakamura, Seiji; Igarashi, Tatsushi

    1978-01-01

    An ultra-micro amount of thallium could be determined by the isotope dilution-surface ionization mass spectrometry by using 203 Tl as a spike. After thallium was separately extracted into 10 ml of 0.00125% dithizone chloroform solution from the solution of the sample isotopically equilibrated with the 203 Tl spike, it was back extracted into 5 ml of 1% nitric acid. The nitric acid solution was treated with a mixture of 0.2 ml of 14 N nitric acid and 0.1 ml of 60% perchloric acid, and evaporated to dryness in a pyrex glass oven supplied with highly pure nitrogen. The residue was dissolved in a mixture of 60 μl of water with 0.015% silica gel suspension and 5 μl of 2% phosphoric acid solution. An aliquot of this mixture was loaded onto a rhenium single filament as an ionization equipment of a Hitachi RMU-6 type mass spectrometer. The detection limit of the present method was 10 -15 -- 10 -14 g for thallium. The precision concerning mass spectroscopic analysis, as a coefficient of variation for the measurements of 205 Tl/ 203 Tl ratios, was 0.1 -- 0.5%. The application of the present method to environmental materials such as Japanese standard rocks and Orchard Leaves delivered by N.B.S. has shown that the precision of repeated analyses was 0.2 -- 0.7% for a concentration of ppm level. This method has revealed that concentration of thallium in the ocean increased with increasing depth at a ppt level. (author)

  2. Hydromechanical Simulations of Surface Uplift due to CO2 Injection at In Salah (Invited)

    Science.gov (United States)

    Morris, J. P.; Hao, Y.; Foxall, W.; McNab, W. W.

    2009-12-01

    We present recent simulations of the hydromechanical response of the reservoir and overburden associated with CO2 injection at In Salah. Using the best available field data for the reservoir and fault network properties, we are able to demonstrate excellent agreement between simulation and observation. These results are providing new insight into the fate of the CO2 about one of the injectors where intriguing morphology was observed in surface uplift. Additionally, this work is helping to better establish the advantages and limitations of interpreting surface displacements to guide our understanding of fluid fate. The In Salah Project (a joint venture of BP, StatoilHydro and Sonatrach) includes a CO2 sequestration effort that has successfully injected millions of tons of CO2 into a deep saline formation close to a producing gas field in Algeria. We have been funded by the Joint Industry Project (A consortium consisting of BP, StatoilHydro and Sonatrach, hereafter the JIP) and the U.S. Department of Energy to investigate the role of injection induced mechanical deformation and geochemical alteration at the In Salah CO2 storage project. Here we focus upon the hydromechanical portion of the study. We have performed detailed simulations of the hydromechanical response in the vicinity of the KB-502 CO2 injector specifically because the morphology of the observed surface deformation differed from that above the other injectors at the field. First we performed a geomechanical analysis to predict which faults are flow conduits and which are flow barriers. NUFT simulations were performed based upon this information using permeability fields for the reservoir provided by the JIP. These results indicate that the presence of faults in the vicinity of the KB-502 injector may be responsible for the early breakthrough of CO2 observed at a nearby well, KB-5. We have simulated the mm-scale uplift of the overburden and compared the results with observed deformation using InSAR data

  3. Metabolic profile of Kudiezi injection in rats by UHPLC coupled with Fourier transform ion cyclotron resonance mass spectrometry.

    Science.gov (United States)

    Zhang, Jingdan; Zhang, Xiaoxue; Zhao, Yangyang; Song, Aihua; Sun, Wei; Yin, Ran

    2018-02-01

    In this study, a reliable and sensitive ultra-high performance liquid chromatography coupled with fourier transform ion cyclotron resonance mass spectrometry method was developed for the systematic study of the metabolic profile of Kudiezi injection in rat plasma, bile, urine, and feces after intravenous administration of a single dose. The chromatographic separation was performed on an Agilent Eclipse Plus C 18 column (4.6 mm × 50 mm, 1.8 μm) and the identification of prototype components and metabolites was achieved on a Bruker Solarix 7.0 T ultra-high resolution spectrometer in negative ion mode. Results indicated that a total of 76 constituents including 29 prototype compounds and 47 metabolites (10 phase I metabolites and 37 phase II metabolites) were tentatively identified. And the metabolic pathways of these prototype compounds including hydroxylation, dehydrogenation, glucuronidation, and sulfate conjugation. In conclusion, the developed method with high resolution and sensitivity was effective for screening and identification of prototypes and metabolites of Kudiezi injection in vivo. Moreover, these results would provide significant information for further pharmacokinetic and pharmacological research of Kudiezi injection in vivo. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. A problem-solving approach to effective insulin injection for patients at either end of the body mass index.

    Science.gov (United States)

    Juip, Micki; Fitzner, Karen

    2012-06-01

    People with diabetes require skills and knowledge to adhere to medication regimens and self-manage this complex disease. Effective self-management is contingent upon effective problem solving and decision making. Gaps existed regarding useful approaches to problem solving by individuals with very low and very high body mass index (BMI) who self-administer insulin injections. This article addresses those gaps by presenting findings from a patient survey, a symposium on the topic of problem solving, and recent interviews with diabetes educators to facilitate problem-solving approaches for people with diabetes with high and low BMI who inject insulin and/or other medications. In practice, problem solving involves problem identification, definition, and specification; goal and barrier identification are a prelude to generating a set of potential strategies for problem resolution and applying these strategies to implement a solution. Teaching techniques, such as site rotation and ensuring that people with diabetes use the appropriate equipment, increase confidence with medication adherence. Medication taking is more effective when people with diabetes are equipped with the knowledge, skills, and problem-solving behaviors to effectively self-manage their injections.

  5. Associations of Body Mass Index with Sexual Risk-Taking and Injection Drug Use among US High School Students

    Directory of Open Access Journals (Sweden)

    Richard Lowry

    2014-01-01

    Full Text Available The purpose of this study was to determine if body mass index (BMI is associated with behaviors that may increase risk for HIV and other sexually transmitted diseases (STDs among US high school students. We analyzed nationally representative data from the 2005–2011 national Youth Risk Behavior Surveys (YRBS to examine associations of BMI categories with sexual risk behaviors and injection drug use among sexually active high school students, using sex-stratified logistic regression models. Controlling for race/ethnicity and grade, among female and male students, both underweight (BMI < 5th percentile and obesity (BMI ≥ 95th percentile were associated with decreased odds of being currently sexually active (i.e., having had sexual intercourse during the past 3 months. However, among sexually active female students, obese females were more likely than normal weight females to have had 4 or more sex partners (odds ratio, OR = 1.59, not used a condom at last sexual intercourse (OR = 1.30, and injected illegal drugs (OR = 1.98. Among sexually active male students, overweight (85th percentile ≤ BMI < 95th percentile was associated with not using a condom at last sexual intercourse (OR = 1.19 and obesity was associated with injection drug use (OR = 1.42. Among sexually active students, overweight and obesity may be indicators of increased risk for HIV and other STDs.

  6. Constraints on geothermal reservoir volume change calculations from InSAR surface displacements and injection and production data

    Science.gov (United States)

    Kaven, J. Ole; Barbour, Andrew J.; Ali, Tabrez

    2017-04-01

    Continual production of geothermal energy at times leads to significant surface displacement that can be observed in high spatial resolution using InSAR imagery. The surface displacement can be analyzed to resolve volume change within the reservoir revealing the often-complicated patterns of reservoir deformation. Simple point source models of reservoir deformation in a homogeneous elastic or poro-elastic medium can be superimposed to provide spatially varying, kinematic representations of reservoir deformation. In many cases, injection and production data are known in insufficient detail; but, when these are available, the same Green functions can be used to constrain the reservoir deformation. Here we outline how the injection and production data can be used to constrain bounds on the solution by posing the inversion as a quadratic programming with inequality constraints and regularization rather than a conventional least squares solution with regularization. We apply this method to InSAR-derived surface displacements at the Coso and Salton Sea Geothermal Fields in California, using publically available injection and production data. At both geothermal fields the available surface deformation in conjunction with the injection and production data permit robust solutions for the spatially varying reservoir deformation. The reservoir deformation pattern resulting from the constrained quadratic programming solution is more heterogeneous when compared to a conventional least squares solution. The increased heterogeneity is consistent with the known structural controls on heat and fluid transport in each geothermal reservoir.

  7. Comparison of peri-implant bone formation around injection-molded and machined surface zirconia implants in rabbit tibiae

    OpenAIRE

    Kim, Hong-Kyun; Woo, Kyung mi; Shon, Won-Jun; Ahn, Jin-Soo; Cha, Seunghee; Park, Young-Seok

    2015-01-01

    The aim of this study was to compare osseointegration and surface characteristics of zirconia implants made by the powder injection molding (PIM) technique and made by the conventional milling procedure in rabbit tibiae. Surface characteristics of 2 types of implant were evaluated. Sixteeen rabbits received 2 types of external hex implants with similar geometry, machined zirconia implants and PIM zirconia implants, in the tibiae. Removal torque tests and histomorphometric analyses were perfor...

  8. Hot surface assisted compression ignition in a direct injection natural gas engine

    Energy Technology Data Exchange (ETDEWEB)

    Aesoey, Vilmar

    1996-12-31

    This study investigates the problem of ignition in a direct injection natural gas engine. Due to poor auto-ignition properties of natural gas compared to regular diesel engine fuels, a special arrangement to assist and secure ignition is required. The objective was to investigate the feasibility of using a hot surface as ignition assistance, primarily for application in medium and large size engines, and further study the main mechanisms involved in the ignition process. A constant volume combustion bomb and a test engine are used for experiments, supported by theoretical analysis and numerical simulations. Variable composition of natural gas depending on the gas source and over time, is a important problem causing significant variation in ignition properties. It is shown that even small quantities of non-methane components, which are normally present in natural gases, strongly influence ignition. Actions to handle the ignition problem caused by variable natural composition, are also discussed. In order to estimate the ignition properties of natural gas, a simple correlation to gas composition is proposed, showing good correlation to the experimental data. Mathematical models for simulation of the processes are developed based on fundamental physical relations and experimental results. They are mainly used in this study to support and analyze the physical experiments, but can also be useful in future design and optimization processes. 71 refs., 80 figs., 6 tabs.

  9. Precision injection molding of freeform optics

    Science.gov (United States)

    Fang, Fengzhou; Zhang, Nan; Zhang, Xiaodong

    2016-08-01

    Precision injection molding is the most efficient mass production technology for manufacturing plastic optics. Applications of plastic optics in field of imaging, illumination, and concentration demonstrate a variety of complex surface forms, developing from conventional plano and spherical surfaces to aspheric and freeform surfaces. It requires high optical quality with high form accuracy and lower residual stresses, which challenges both optical tool inserts machining and precision injection molding process. The present paper reviews recent progress in mold tool machining and precision injection molding, with more emphasis on precision injection molding. The challenges and future development trend are also discussed.

  10. Method for 236U Determination in Seawater Using Flow Injection Extraction Chromatography and Accelerator Mass Spectrometry

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Steier, Peter

    2015-01-01

    An automated analytical method implemented in a flow injection (FI) system was developed for rapid determination of 236U in 10 L seawater samples. 238U was used as a chemical yield tracer for the whole procedure, in which extraction chromatography (UTEVA) was exploited to purify uranium, after...... experimental parameters affecting the analytical effectiveness were investigated and optimized in order to achieve high chemical yields and simple and rapid analysis as well as low procedure background. Besides, the operational conditions for the target preparation prior to the AMS measurement were optimized......, on the basis of studying the coprecipitation behavior of uranium with iron hydroxide. The analytical results indicate that the developed method is simple and robust, providing satisfactory chemical yields (80−100%) and high analysis speed (4 h/sample), which could be an appealing alternative to conventional...

  11. Quantitative Thin-Layer Chromatography/Mass Spectrometry Analysis of Caffeine Using a Surface Sampling Probe Electrospray Ionization Tandem Mass Spectrometry System

    Energy Technology Data Exchange (ETDEWEB)

    Ford, Michael J [ORNL; Deibel, Michael A. [Earlham College; Tomkins, Bruce A [ORNL; Van Berkel, Gary J [ORNL

    2005-01-01

    Quantitative determination of caffeine on reversed-phase C8 thin-layer chromatography plates using a surface sampling electrospray ionization system with tandem mass spectrometry detection is reported. The thin-layer chromatography/electrospray tandem mass spectrometry method employed a deuterium-labeled caffeine internal standard and selected reaction monitoring detection. Up to nine parallel caffeine bands on a single plate were sampled in a single surface scanning experiment requiring 35 min at a surface scan rate of 44 {mu}m/s. A reversed-phase HPLC/UV caffeine assay was developed in parallel to assess the mass spectrometry method performance. Limits of detection for the HPLC/UV and thin-layer chromatography/electrospray tandem mass spectrometry methods determined from the calibration curve statistics were 0.20 ng injected (0.50 {mu}L) and 1.0 ng spotted on the plate, respectively. Spike recoveries with standards and real samples ranged between 97 and 106% for both methods. The caffeine content of three diet soft drinks (Diet Coke, Diet Cherry Coke, Diet Pepsi) and three diet sport drinks (Diet Turbo Tea, Speed Stack Grape, Speed Stack Fruit Punch) was measured. The HPLC/UV and mass spectrometry determinations were in general agreement, and these values were consistent with the quoted values for two of the three diet colas. In the case of Diet Cherry Coke and the diet sports drinks, the determined caffeine amounts using both methods were consistently higher (by 8% or more) than the literature values.

  12. Vapour explosions (fuel-coolant interactions) resulting from the sub-surface injection of water into molten metals: preliminary results

    International Nuclear Information System (INIS)

    Asher, R.C.; Bullen, D.; Davies, D.

    1976-03-01

    Preliminary experiments are reported on the relationship between the injection mode of contact and the occurrence and magnitude of vapour explosions. Water was injected beneath the surface of molten metals, chiefly tin at 250 to 900 0 C. Vapour explosions occurred in many, but not all, cases. The results are compared with Dullforce's observations (Culham Report (CLM-P424) on the dropping mode of contact and it appears that rather different behaviour is found; in particular, the present results suggest that the Temperature Interaction Zone is different for the two modes of contact. (author)

  13. Electron spin injection from a regrown Fe layer in a spin-polarized vertical-cavity surface-emitting laser

    Science.gov (United States)

    Holub, M.; Bhattacharya, P.; Shin, J.; Saha, D.

    2007-04-01

    An electroluminescence circular polarization of 23% and threshold current reduction of 11% are obtained in an electrically pumped spin-polarized vertical-cavity surface-emitting laser. Electron spin injection is accomplished utilizing a regrown Fe/ n-AlGaAs Schottky tunnel barrier deposited around the base of the laser mesas. Negligible circular polarizations and threshold current reductions are measured for nonmagnetic and Fe-based control VCSELs, which provides convincing evidence of spin injection, transport, and detection in our spin-polarized laser.

  14. Advanced Production Surface Preparation Technology Development for Ultra-High Pressure Diesel Injection

    Energy Technology Data Exchange (ETDEWEB)

    Grant, Marion B.

    2012-04-30

    In 2007, An Ultra High Injection Pressure (UHIP) fueling method has been demonstrated by Caterpillar Fuel Systems - Product Development, demonstrating ability to deliver U.S. Environment Protection Agency (EPA) Tier 4 Final diesel engine emission performance with greatly reduced emissions handling components on the engine, such as without NOx reduction after-treatment and with only a through-flow 50% effective diesel particulate trap (DPT). They have shown this capability using multiple multi-cylinder engine tests of an Ultra High Pressure Common Rail (UHPCR) fuel system with higher than traditional levels of CEGR and an advanced injector nozzle design. The system delivered better atomization of the fuel, for more complete burn, to greatly reduce diesel particulates, while CEGR or high efficiency NOx reduction after-treatment handles the NOx. With the reduced back pressure of a traditional DPT, and with the more complete fuel burn, the system reduced levels of fuel consumption by 2.4% for similar delivery of torque and horsepower over the best Tier 4 Interim levels of fuel consumption in the diesel power industry. The challenge is to manufacture the components in high-volume production that can withstand the required higher pressure injection. Production processes must be developed to increase the toughness of the injector steel to withstand the UHIP pulsations and generate near perfect form and finish in the sub-millimeter size geometries within the injector. This project resulted in two developments in 2011. The first development was a process and a machine specification by which a high target of compressive residual stress (CRS) can be consistently imparted to key surfaces of the fuel system to increase the toughness of the steel, and a demonstration of the feasibility of further refinement of the process for use in volume production. The second development was the demonstration of the feasibility of a process for imparting near perfect, durable geometry to

  15. Surface characterisation and functionalisation of indium tin oxide anodes for improvement of charge injection in organic light emitting diodes

    International Nuclear Information System (INIS)

    Davenas, J.; Besbes, S.; Abderrahmen, A.; Jaffrezic, N.; Ben Ouada, H.

    2008-01-01

    Wettability studies have been performed to probe the surface properties of ITO substrates, aimed to be used as hole injecting electrode in OLEDs. The elimination of organic contaminants upon the cleaning treatment (ultrasonic bath in organic solvents) leads to an increase of the free energy of the ITO surface becoming hydrophilic. The surface energy components calculated from the Van Oss model show the appearance of a basic component upon the cleaning treatment. A thermal treatment at 100 deg. C for 3 h leads to a decrease of the surface free energy due to surface dehydration. These properties are attributed to the hydroxides formed at the ITO surface inducing improved adhesion at the ITO/polymer interface. The ITO surfaces have been functionalised with a chloroethylphosphonic acid mono-layer to increase their stability. The appearance of an acid-base component leads to a dipolar character of the ITO surface. The formation of a compact layer of a spin coated poly(phenylenevinylene) derivative induces the shielding of the ITO basic character. The weakening of the near infrared absorption associated to ITO free carriers confirms the formation of a dipole layer at the interface with the molecular layer in contact with ITO. Improved injection properties, shown by the current/voltage characteristics, result from the interface modifications

  16. Single injection of the β2-adrenergic receptor agonist, clenbuterol, into newly hatched chicks alters abdominal fat pad mass in growing birds.

    Science.gov (United States)

    Ishimaru, Yoshitaka; Ijiri, Daichi; Shimamoto, Saki; Ishitani, Kanae; Nojima, Tsutomu; Ohtsuka, Akira

    2015-01-15

    Excessive energy is stored in white adipose tissue as triacylglycerols in birds as well as in mammals. Although β2-adrenergic receptor agonists reduce adipose tissue mass in birds, the underlying mechanism remains unclear. The aim of the current study was to examine the effects of a single intraperitoneal injection of the β2-adrenergic receptor agonist, clenbuterol, on the abdominal fat pad tissue development. Thirty-three chicks at 1-day-old were given a single intraperitoneal injection of clenbuterol (0.1mg/kg body weight) or phosphate-buffered saline. At 2 weeks post-dose, the weight of the abdominal fat tissue was decreased in the clenbuterol-injected chicks, and small adipocyte-like cells were observed in the abdominal fat pad tissue of the clenbuterol-injected chicks. Then, the expression of mRNAs encoding genes related to avian adipogenesis was examined in the abdominal fat pat tissue. The expression of mRNAs encoding Krüppel-like zinc finger transcription factor 5 (KLF-5), KLF-15, and zinc finger protein 423 in the abdominal fat pad tissue of the clenbuterol-injected chicks was significantly lower (Pclenbuterol-injected chicks, while clenbuterol injection did not affect FAS activity in liver. These results suggested that a single injection with clenbuterol into newly hatched chicks reduces their abdominal fat pad mass possibly via disrupting adipocyte development during later growth stages. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Replication of micro and nano-features on iPP by injection molding with fast cavity surface temperature evolution

    DEFF Research Database (Denmark)

    Speranzaa, Vito; Liparotia, Sara; Calaon, Matteo

    2017-01-01

    The production of polymeric components with functional structures in the micrometer and sub-micrometer range is a complex challenge for the injection molding process, since it suffers the use of low cavity surface temperatures that induce the fast formation of a frozen layer, thus preventing...... was sufficient to obtain accurate replication, with adequate surface temperatures. In the case of nano-features, the replication accuracy was affected by the morphology developed on the molding surface, that is aligned along the flow direction with dimensions comparable with the dimension of the nano...

  18. Orthogonal Injection Ion Funnel Interface Providing Enhanced Performance for Selected Reaction Monitoring-Triple Quadrupole Mass Spectrometry.

    Science.gov (United States)

    Chen, Tsung-Chi; Fillmore, Thomas L; Prost, Spencer A; Moore, Ronald J; Ibrahim, Yehia M; Smith, Richard D

    2015-07-21

    The electrodynamic ion funnel facilitates efficient focusing and transfer of charged particles in the higher-pressure regions (e.g., ion source interfaces) of mass spectrometers, thus providing increased sensitivity. An "off-axis" ion funnel design has been developed to reduce the source contamination and interferences from, e.g. ESI droplet residue and other poorly focused neutral or charged particles with very high mass-to-charge ratios. In this study, a dual ion funnel interface consisting of an orthogonal higher pressure electrodynamic ion funnel (HPIF) and an ion funnel trap combined with a triple quadrupole mass spectrometer was developed and characterized. An orthogonal ion injection inlet and a repeller plate electrode was used to direct ions to an ion funnel HPIF at a pressure of 9-10 Torr. Key factors for the HPIF performance characterized included the effects of RF amplitude, the DC gradient, and operating pressure. Compared to the triple quadrupole standard interface more than 4-fold improvement in the limit of detection for the direct quantitative MS analysis of low abundance peptides was observed. The sensitivity enhancement in liquid chromatography selected reaction monitoring (LC-SRM) analyses of low-abundance peptides spiked into a highly complex mixture was also compared with that obtained using both a commercial S-lens interface and an in-line dual-ion funnel interface.

  19. Unambiguous identification and discovery of bacterial siderophores by direct injection 21 Tesla Fourier transform ion cyclotron resonance mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Lawrence R.; Tfaily, Malak M.; Shaw, Jared B.; Hess, Nancy J.; Pasa Tolic, Ljiljana; Koppenaal, David W.

    2017-01-01

    Under iron-limiting conditions, bacteria produce low molecular mass Fe(III) binding molecules known as siderophores to sequester the Fe(III), along with other elements, increasing their bioavailibility. Siderophores are thought to influence iron cycling and biogeochemistry in both marine and terrestrial ecosystems and hence the need for rapid, confident characterization of these compounds has increased. In this study, the type of siderophores produced by two marine bacterial species, Synechococcus sp. PCC 7002 and Vibrio cyclitrophicus 1F53, were characterized using a newly developed 21T Fourier Transform Ion Cyclotron Resonance Mass Spectrometer (FTICR MS) with direct injection electrospray ionization. This technique allowed for the rapid detection of synechobactins from Synechococcus sp. PCC 7002 as well as amphibactins from Vibrio cyclitrophicus 1F53 based on high mass accuracy and resolution allowing for observation of specific Fe isotopic peaks and fine isotopic structure enables highly confident identification of these sideropohores. When combined with molecular network analysis two new amphibactins were discovered and verified by tandem MS. These results show that high-field FTICR MS is a powerful technique that will greatly improve the ability to rapidly identify and discover metal binding species in the environment.

  20. Surface-MALDI mass spectrometry in biomaterials research

    DEFF Research Database (Denmark)

    Griesser, H.J.; Kingshott, P.; McArthur, S.L.

    2004-01-01

    Matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS) has been used for over a decade for the determination of purity and accurate molecular masses of macromolecular analytes, such as proteins, in solution. In the last few years the technique has been adapted to become a new...

  1. Determination of pesticides and pesticide degradates in filtered water by direct aqueous-injection liquid chromatography-tandem mass spectrometry

    Science.gov (United States)

    Sandstrom, Mark W.; Kanagy, Leslie K.; Anderson, Cyrissa A.; Kanagy, Christopher J.

    2016-01-11

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for determination of 229 pesticides compounds (113 pesticides and 116 pesticide degradates) in filtered water samples from stream and groundwater sites. The pesticides represent a broad range of chemical classes and were selected based on criteria such as current-use intensity, probability of occurrence in streams and groundwater, and toxicity to humans or aquatic organisms. More than half of the analytes are pesticide degradates. The method involves direct injection of a 100-microliter (μL) sample onto the LC-MS/MS without any sample preparation other than filtration. Samples are analyzed with two injections, one in electrospray ionization (ESI) positive mode and one in ESI negative mode, using dynamic multiple reaction monitoring (MRM) conditions, with two MRM transitions for each analyte. The LC-MS/MS instrument parameters were optimized for highest sensitivity for the most analytes. This report describes the analytical method and presents characteristics of the method validation including bias and variability, detection levels, and holding-time studies.

  2. A Customizable Flow Injection System for Automated, High Throughput, and Time Sensitive Ion Mobility Spectrometry and Mass Spectrometry Measurements.

    Science.gov (United States)

    Orton, Daniel J; Tfaily, Malak M; Moore, Ronald J; LaMarche, Brian L; Zheng, Xueyun; Fillmore, Thomas L; Chu, Rosalie K; Weitz, Karl K; Monroe, Matthew E; Kelly, Ryan T; Smith, Richard D; Baker, Erin S

    2018-01-02

    To better understand disease conditions and environmental perturbations, multiomic studies combining proteomic, lipidomic, and metabolomic analyses are vastly increasing in popularity. In a multiomic study, a single sample is typically extracted in multiple ways, and various analyses are performed using different instruments, most often based upon mass spectrometry (MS). Thus, one sample becomes many measurements, making high throughput and reproducible evaluations a necessity. One way to address the numerous samples and varying instrumental conditions is to utilize a flow injection analysis (FIA) system for rapid sample injections. While some FIA systems have been created to address these challenges, many have limitations such as costly consumables, low pressure capabilities, limited pressure monitoring, and fixed flow rates. To address these limitations, we created an automated, customizable FIA system capable of operating at a range of flow rates (∼50 nL/min to 500 μL/min) to accommodate both low- and high-flow MS ionization sources. This system also functions at varying analytical throughputs from 24 to 1200 samples per day to enable different MS analysis approaches. Applications ranging from native protein analyses to molecular library construction were performed using the FIA system, and results showed a highly robust and reproducible platform capable of providing consistent performance over many days without carryover, as long as washing buffers specific to each molecular analysis were utilized.

  3. Fast gas chromatographic residue analysis in animal feed using split injection and atmospheric pressure chemical ionisation tandem mass spectrometry.

    Science.gov (United States)

    Tienstra, M; Portolés, T; Hernández, F; Mol, J G J

    2015-11-27

    Significant speed improvement for instrumental runtime would make GC–MS much more attractive for determination of pesticides and contaminants and as complementary technique to LC–MS. This was the trigger to develop a fast method (time between injections less than 10 min) for the determination of pesticides and PCBs that are not (or less) amenable to LC–MS. A key factor in achieving shorter analysis time was the use of split injection (1:10) which allowed the use of a much higher initial GC oven temperature. A shorter column (15 m), higher temperature ramp, and higher carrier gas flow rate (6 mL/min) further contributed to analysis-time reduction. Chromatographic resolution was slightly compromised but still well fit-for-purpose. Due to the high sensitivity of the technique used (GC–APCI-triple quadrupole MS/MS), quantification and identification were still possible down to the 10 μg/kg level, which was demonstrated by successful validation of the method for complex feed matrices according to EU guidelines. Other advantages of the method included a better compatibility of acetonitrile extracts (e.g. QuEChERS) with GC, and a reduced transfer of co-extractants into the GC column and mass spectrometer.

  4. High-rate production of micro- and nanostructured surfaces: Injection molding and novel process for metal tooling manufacturing

    Science.gov (United States)

    De Jesus Vega, Marisely

    Devices containing micro and nanostructured surfaces are developing and constantly finding new applications, especially for medical diagnostics, point-of-care applications, and microneedles. They are also employed in the functionalization of surfaces for superhydrophobicity, drag reduction, or reversible adhesion by mimicking bio-inspired surfaces. This research provides a thorough investigation on the effects of different polymeric materials and processing conditions on the replication of micro and nanostructured surfaces via injection molding. In addition, this dissertation also presents a novel approach for the production of durable microstructured metal tooling to be used for the production of surfaces with microchannels via injection molding. Materials such as thermoplastic vulcanizates are substituting regular thermoplastic materials and vulcanized elastomers in many applications due to their outstanding properties and ease of processability. These material properties broaden the scope of applications for microstructured surfaces. However, there is a need for understanding how these materials behave in microinjection molding since thermoplastic elastomers' behavior during injection molding have been shown to differ from that of the widely understood behavior of thermoplastics. Replication of microstructured surfaces using thermoplastic vulcanizates (TPV) was studied in the first part of this thesis. TPVs with different hardness's were molded using microinjection molding with various processing conditions and the replication and surface details of 20 microm pillars (aspect ratio of 1:1) were characterized. In the second part of this research liquid silicone rubber (LSR) was studied as a material for the production of micro and nanostructured surfaces. LSR is a silicone based material such as polydimethylsiloxane (PDMS), which is widely used for research and development of micro and nanostructured devices, and thus provides all the benefits of PDMS but can be

  5. Surface-downhole and crosshole geoelectrics for monitoring of brine injection at the Ketzin CO2 storage site

    Science.gov (United States)

    Rippe, Dennis; Bergmann, Peter; Labitzke, Tim; Wagner, Florian; Schmidt-Hattenberger, Cornelia

    2016-04-01

    The Ketzin pilot site in Germany is the longest operating on-shore CO2 storage site in Europe. From June 2008 till August 2013, a total of ˜67,000 tonnes of CO2 were safely stored in a saline aquifer at depths of 630 m to 650 m. The storage site has now entered the abandonment phase, and continuation of the multi-disciplinary monitoring as part of the national project "CO2 post-injection monitoring and post-closure phase at the Ketzin pilot site" (COMPLETE) provides the unique chance to participate in the conclusion of the complete life cycle of a CO2 storage site. As part of the continuous evaluation of the functionality and integrity of the CO2 storage in Ketzin, from October 12, 2015 till January 6, 2015 a total of ˜2,900 tonnes of brine were successfully injected into the CO2 reservoir, hereby simulating in time-lapse the natural backflow of brine and the associated displacement of CO2. The main objectives of this brine injection experiment include investigation of how much of the CO2 in the pore space can be displaced by brine and if this displacement of CO2 during the brine injection differs from the displacement of formation fluid during the initial CO2 injection. Geophysical monitoring of the brine injection included continuous geoelectric measurements accompanied by monitoring of pressure and temperature conditions in the injection well and two adjacent observation wells. During the previous CO2 injection, the geoelectrical monitoring concept at the Ketzin pilot site consisted of permanent crosshole measurements and non-permanent large-scale surveys (Kiessling et al., 2010). Time-lapse geoelectrical tomographies derived from the weekly crosshole data at near-wellbore scale complemented by six surface-downhole surveys at a scale of 1.5 km showed a noticeable resistivity signature within the target storage zone, which was attributed to the CO2 plume (Schmidt-Hattenberger et al., 2011) and interpreted in terms of relative CO2 and brine saturations (Bergmann

  6. Greenland surface mass-balance observations from the ice-sheet ablation area and local glaciers

    DEFF Research Database (Denmark)

    Machguth, Horst; Thomsen, Henrik H.; Weidick, Anker

    2016-01-01

    Glacier surface mass-balance measurements on Greenland started more than a century ago, but no compilation exists of the observations from the ablation area of the ice sheet and local glaciers. Such data could be used in the evaluation of modelled surface mass balance, or to document changes in g...

  7. Greenland surface mass-balance observations from the ice-sheet ablation area and local glaciers

    NARCIS (Netherlands)

    Machguth, Horst; Thomsen, Henrik H.; Weidick, Anker; Ahlstrøm, Andreas P.; Abermann, Jakob; Andersen, Morten L.; Andersen, Signe B.; Bjørk, Anders A.; Box, Jason E.; Braithwaite, Roger J.; Bøggild, Carl E.; Citterio, Michele; Clement, Poul; Colgan, William; Fausto, Robert S.; Gleie, Karin; Gubler, Stefanie; Hasholt, Bent; Hynek, Bernhard; Knudsen, Niels T.; Larsen, Signe H.; Mernild, Sebastian H.; Oerlemans, Johannes; Oerter, Hans; Olesen, Ole B.; Smeets, C. J P Paul; Steffen, Konrad; Stober, Manfred; Sugiyama, Shin; Van As, Dirk; Van Den Broeke, Michiel R.; Van De Wal, Roderik S W

    2016-01-01

    Glacier surface mass-balance measurements on Greenland started more than a century ago, but no compilation exists of the observations from the ablation area of the ice sheet and local glaciers. Such data could be used in the evaluation of modelled surface mass balance, or to document changes in

  8. Large volume cold on-column injection for gas chromatography-negative chemical ionization-mass spectrometry analysis of selected pesticides in air samples.

    Science.gov (United States)

    Bailey, Renata; Belzer, Wayne

    2007-02-21

    A new gas chromatographic method is described for the analysis of fungicides captan, captafol, and folpet from organic extracts of air samples using large volume injection (LVI) via a cold on-column (COC) inlet coupled with gas chromatography-negative chemical ionization-mass spectrometry (GC-NCI-MS). Although standard split/splitless injection due to high injection port temperatures (>225 degrees C) have been shown to degrade these thermally labile fungicides, COC injection minimizes degradation. Insecticides such as chlorpyrifos and diazinon were also examined to show added selectivity. By using a solvent vapor exit with the COC inlet, injection volumes of 10-100 microL can be made to lower detection levels. GC-NCI-MS was compared to GC-electron impact ionization-mass spectrometry for each pesticide using LVI-COC injections and was found to be 2-80 times more sensitive, depending on the pesticide. Method detection limit (MDL) values with 100 microL injections were 2.5 microg L-1 for captan, folpet, and diazinon, 5.0 microg L-1 captafol, and 1.0 microg L-1 for chlorpyrifos, with the normal working range examined for sample analysis from MDL to 100 microg L-1. Detection of all pesticides except captafol, used only in the United States but not Canada, was demonstrated from air samples taken from Abbotsford, British Columbia, Canada.

  9. Greenland surface mass-balance observations from the ice-sheet ablation area and local glaciers

    DEFF Research Database (Denmark)

    Machguth, Horst; Thomsen, Henrik H.; Weidick, Anker

    2016-01-01

    Glacier surface mass-balance measurements on Greenland started more than a century ago, but no compilation exists of the observations from the ablation area of the ice sheet and local glaciers. Such data could be used in the evaluation of modelled surface mass balance, or to document changes...... in glacier melt independently from model output. Here, we present a comprehensive database of Greenland glacier surface mass-balance observations from the ablation area of the ice sheet and local glaciers. The database spans the 123 a from 1892 to 2015, contains a total of similar to 3000 measurements from......-term time series of which there are only two exceeding 20 a. We use the data to analyse uncertainties in point measurements of surface mass balance, as well as to estimate surface mass-balance profiles for most regions of Greenland....

  10. Characterizing near-surface CO2 conditions before injection - Perspectives from a CCS project in the Illinois Basin, USA

    Science.gov (United States)

    Locke, R.A.; Krapac, I.G.; Lewicki, J.L.; Curtis-Robinson, E.

    2011-01-01

    The Midwest Geological Sequestration Consortium is conducting a large-scale carbon capture and storage (CCS) project in Decatur, Illinois, USA to demonstrate the ability of a deep saline formation to store one million tonnes of carbon dioxide (CO2) from an ethanol facility. Beginning in early 2011, CO2 will be injected at a rate of 1,000 tonnes/day for three years into the Mount Simon Sandstone at a depth of approximately 2,100 meters. An extensive Monitoring, Verification, and Accounting (MVA) program has been undertaken for the Illinois Basin Decatur Project (IBDP) and is focused on the 0.65 km2 project site. Goals include establishing baseline conditions to evaluate potential impacts from CO2 injection, demonstrating that project activities are protective of human health and the environment, and providing an accurate accounting of stored CO2. MVA efforts are being conducted pre-, during, and post- CO2 injection. Soil and net CO2 flux monitoring has been conducted for more than one year to characterize near-surface CO2 conditions. More than 2,200 soil CO2 flux measurements have been manually collected from a network of 118 soil rings since June 2009. Three ring types have been evaluated to determine which type may be the most effective in detecting potential CO 2 leakage. Bare soil, shallow-depth rings were driven 8 cm into the ground and were prepared to minimize surface vegetation in and near the rings. Bare soil, deep-depth rings were prepared similarly, but were driven 46 cm. Natural-vegetation, shallow-depth rings were driven 8 cm and are most representative of typical vegetation conditions. Bare-soil, shallow-depth rings had the smallest observed mean flux (1.78 ??mol m-2 s-1) versus natural-vegetation, shallow-depth rings (3.38 ??mol m-2 s-1). Current data suggest bare ring types would be more sensitive to small CO2 leak signatures than natural ring types because of higher signal to noise ratios. An eddy covariance (EC) system has been in use since June

  11. Effects of mass transfer between Martian satellites on surface geology

    Science.gov (United States)

    2015-12-21

    suspected. Published by Elsevier Inc.1. Introduction Several features about the surface geology on the moons of Mars remain poorly understood. The grooves on...Deimos may have an effect on Phobos’ geology ; we shall attempt to estimate the magnitude of that effect in Section 4. For impacts with Mars, Phobos or...global surface geology , particularly in the 100+ Ma since the last Voltaire-sized impact. Therefore we believe it unlikely that the red veneer of

  12. Mass transfer from smooth alabaster surfaces in turbulent flows

    Science.gov (United States)

    Opdyke, Bradley N.; Gust, Giselher; Ledwell, James R.

    1987-11-01

    The mass transfer velocity for alabaster plates in smooth-wall turbulent flow is found to vary with the friction velocity according to an analytic solution of the advective diffusion equation. Deployment of alabaster plates on the sea floor can perhaps be used to estimate the viscous stress, and transfer velocities for other species.

  13. Application of an on-line flow injection high resolution inductivity coupled plasma mass spectrometry to the determination of Pu isotopes in soil and seawater

    International Nuclear Information System (INIS)

    Kim, Chang-Kyu; Kim, Cheol-Su; Rho, Byung-Hwan; Lee, Jong-Inn

    2000-01-01

    High resolution inductively coupled plasma mass spectrometry combined with an on-line flow injection system (FI-HR-ICP-MS) was applied to the determination of ultra-trace level 239 Pu and 240 Pu and their atomic ratio ( 240 Pu/ 239 Pu) in soil and seawater samples. To reduce the interference effect of 238 U, MCN-6000(R) was used as a sample introduction system, which showed a 5-fold reduction in 238 UH + formation, compared to the conventional pneumatic nebulizer. The flow injection system (PrepLab(TM)) coupled with HR-ICP-MS, which was composed of Sr-Spec(R) and TEVA-Spec(R) resins, reduced significantly the sample volume and the analysis time, compared to the conventional method of Pu isotopes. With this method, it was possible to determine ultra-low level of Pu in only 0.5 g soil and 5L surface seawater with an analysis speed of 3 - 5 hours per sample. The accuracy of this method was verified by the spike recovery experiments and by the comparison of results obtained from the on-line FI-HR-ICP-MS method with one from alpha spectrometry. In spite of small amount sample, the RSD in the determination of 239 Pu and 240 Pu by the on-line FI-HR-ICP-MS were less than 7%. The analytical results of the NIST reference material obtained by the present method agreed with certified values within a 10% of relative error. The detection limits for 239 Pu and 240 Pu were 1.27 fg m -1 (2.92 μBq ml -1 ) and 0.88 fg ml -1 (7.38 μBq ml -1 ), respectively. (author)

  14. Peri-implant bone formation and surface characteristics of rough surface zirconia implants manufactured by powder injection molding technique in rabbit tibiae.

    Science.gov (United States)

    Park, Young-Seok; Chung, Shin-Hye; Shon, Won-Jun

    2013-05-01

    To evaluate osseointegration in rabbit tibiae and to investigate surface characteristics of novel zirconia implants made by powder injection molding (PIM) technique, using molds with and without roughened inner surfaces. A total of 20 rabbits received three types of external hex implants with identical geometry on the tibiae: machined titanium implants, PIM zirconia implants without mold etching, and PIM zirconia implants with mold etching. Surface characteristics of the three types of implant were evaluated. Removal torque tests and histomorphometric analyses were performed. The roughness of PIM zirconia implants was higher than that of machined titanium implants. The PIM zirconia implants exhibited significantly higher bone-implant contact and removal torque values than the machined titanium implants (P mold showed significantly higher removal torque values than PIM zirconia implants without using roughened mold (P mold etching technique can produce substantially rough surfaces on zirconia implants. © 2012 John Wiley & Sons A/S.

  15. Significancy in atomic mass measurements and the topography of the mass-surface

    International Nuclear Information System (INIS)

    Audi, G.

    1991-01-01

    It is discussed how to explore new regions of the chart of the nuclides through masses, and what has to be understood under significant mass measurements. In the exploratory phase of a new region of the chart, a result with almost any accuracy is appropriate. The higher the accuracy is, the better the possibility is to see finer structures. (G.P.) 24 refs.; 10 figs

  16. Differentiation of the four major types (C. Burmannii, C. Verum, C. cassia, And C. Loureiroi) of cinnamons using a flow-injection mass spectrometric (FIMS) fingerprinting method

    Science.gov (United States)

    A simple and efficient flow-injection mass spectrometric (FIMS) method was developed to differentiate cinnamon (Cinnamomum) bark (CB) samples of the four major species (C. burmannii, C. verum, C. aromaticum, and C. loureiroi) of cinnamon. Fifty cinnamon samples collected from China, Vietnam, Indon...

  17. Differentiation of the two major species of Echinacea (E. augustifolia and E. purpurea) using a flow injection mass spectrometric (FIMS) fingerprinting method and chemometric analysis

    Science.gov (United States)

    A rapid, simple, and reliable flow-injection mass spectrometric (FIMS) method was developed to discriminate two major Echinacea species (E. purpurea and E. angustifolia) samples. Fifty-eight Echinacea samples collected from United States were analyzed using FIMS. Principle component analysis (PCA) a...

  18. Rapid isolation of biomarkers for compound specific radiocarbon dating using high-performance liquid chromatography and flow injection analysis-atmospheric pressure chemical ionisation mass spectrometry

    NARCIS (Netherlands)

    Sinninghe Damsté, J.S.; Smittenberg, R.H.; Hopmans, E.C.; Schouten, S.

    2002-01-01

    Repeated semi-preparative normal-phase HPLC was performed to isolate selected biomarkers from sediment extracts for radiocarbon analysis. Flow injection analysis mass spectrometry was used for rapid analysis of collected fractions to evaluate the separation procedure, taking only 1 min per fraction.

  19. Flow injection on-line dilution for multi-element determination in human urine with detection by inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald; Gammelgaard, Bente

    2001-01-01

    A simple flow injection on-line dilution procedure with detection by inductively coupled plasma mass spectrometry (ICP-MS) was developed for the determination of copper, zinc, arsenic, lead, selenium, nickel and molybdenum in human urine. Matrix effects were minimized by employing a dilution factor...

  20. Microporous Titanium through Metal Injection Moulding of Coarse Powder and Surface Modification by Plasma Oxidation

    OpenAIRE

    Shbeh, Mohammed; Yerokhin, Aleksey; Goodall, Russell

    2017-01-01

    Titanium is one of the most attractive materials for biomedical applications due to having excellent biocompatibility accompanied by good corrosion resistance. One popular processing technique for Ti is Metal Injection Moulding (MIM). However, there are several issues associated with the use of this technique, such as the high cost of the fine powder used, the high level of contamination and consequent alteration to material properties, as well as the large volume shrinkage that occurs during...

  1. Impact of Body Mass Index on Outcomes of In Vitro Fertilization/Intracytoplasmic Sperm Injection Among Polycystic Ovarian Syndrome Patients

    Directory of Open Access Journals (Sweden)

    Na Cui

    2016-10-01

    Full Text Available Background: The aim of this study is to assess the effect of body mass index (BMI on outcomes of in vitro fertilization (IVF / intracytoplasmic sperm injection (ICSI among polycystic ovarian syndrome (PCOS and non-PCOS patients. Methods: This was a retrospective cohort study that was performed in the Second Hospital of Hebei Medical University. Patients who were under 35 years old were included in the study and were divided into four groups based on their BMI. The number of retrieved oocytes, implantation rate, clinical pregnancy rate, miscarriage rate and live births among PCOS and non-PCOS patients were compared between different BMIs. Results: IVF/ICSI pregnancies in obese PCOS women had a considerably higher risk of miscarriage and low rate of clinical pregnancy than in non-obese PCOS pregnancies. However, in non-PCOS patient, obesity significantly elevated miscarriage rate but did not affect clinical pregnancy rate. Conclusion: Obesity in PCOS patients led to poor outcomes of IVF/ICSI.

  2. Evaluation of volatile compounds in different types of ghee using direct injection with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Wadodkar, Uday R; Punjrath, Jagjit S; Shah, Amrish C

    2002-02-01

    Desi ghee (DG) was prepared from fermented cream followed by heat clarification (desi method) in the laboratory and butter oil (BO) was prepared from fresh butter by melting and centrifugation. Fresh samples of three brands of industrial ghee (IG-1, IG-2, IG-3) were collected from the local market. Volatile compounds of desi and industrial ghee and butter oil were isolated and concentrated using direct injection and cryofocussing techniques; separation and identification was by Gas Chromatography Mass Spectrometry (GCMS). A maximum of 36 compounds were detected in desi ghee whereas compounds detected in three industrial ghee samples varied from 22-29. The lowest number of compounds (16) was detected in butter oil. Of the identified compounds, maltol, 5-hydroxymethyl furfuraldehyde, dihydrodihydroxypyranone, 1,3-butanediol and 1-octanol were identified only in desi ghee volatiles. The concentration of acetic acid was found to be remarkably higher in desi ghee volatiles than in industrial ghee. Also the levels of identified fatty acids, methyl ketones, aldehydes, lactones and alcohols were high in desi ghee volatiles compared with industrial ghee and butter oil. In total, 62 compounds were detected, which included 6 aldehydes, 12 ketones, 8 each of fatty acids, alcohols and lactones, 4 each of esters and hydrocarbons or other compounds, and 12 compounds remained unidentified.

  3. Comparison of peri-implant bone formation around injection-molded and machined surface zirconia implants in rabbit tibiae

    Science.gov (United States)

    Kim, Hong-Kyun; Woo, Kyung mi; Shon, Won-Jun; Ahn, Jin-Soo; Cha, Seunghee; Park, Young-Seok

    2017-01-01

    The aim of this study was to compare osseointegration and surface characteristics of zirconia implants made by the powder injection molding (PIM) technique and made by the conventional milling procedure in rabbit tibiae. Surface characteristics of 2 types of implant were evaluated. Sixteeen rabbits received 2 types of external hex implants with similar geometry, machined zirconia implants and PIM zirconia implants, in the tibiae. Removal torque tests and histomorphometric analyses were performed. The roughness of PIM zirconia implants was higher than that of machined zirconia implants. The PIM zirconia implants exhibited significantly higher bone-implant contact and removal torque values than the machined zirconia implants (P zirconia implant is promising, and PIM, using the roughened mold etching technique, can produce substantially rough surfaces on zirconia implants. PMID:26235717

  4. Fabrication of Hierarchically Micro- and Nano-structured Mold Surfaces Using Laser Ablation for Mass Production of Superhydrophobic Surfaces

    Science.gov (United States)

    Noh, Jiwhan; Lee, Jae-Hoon; Na, Suckjoo; Lim, Hyuneui; Jung, Dae-Hwan

    2010-10-01

    Many studies have examined the formation of surfaces with mixed patterns of micro- and nano-sized lotus leaves that have hydrophobic properties. In this study, micro- and nano-shapes such as lotus leaves were fabricated on a metal mold surface using laser ablation and ripple formation. A microstructure on the mold surface was replicated onto poly(dimethylsiloxane) (PDMS) using the polymer casting method to manufacture low-cost hydrophobic surfaces. A PDMS surface with micro- and nano-structures that were the inverse image of a lotus leaf showed hydrophobic characteristics (water contact angle: 157°). From these results, we deduced that portions of the microstructures were wet and that air gaps existed between the microstructures and the water drops. In this paper we suggest the possibility of the mass production of hydrophobic plastic surfaces and the development of a methodology for the hydrophobic texturing of various polymer surfaces, using the polymer casting method with laser-processed molds.

  5. Fabrication of high aspect ratio nanopillars and micro/nano combined structures with hydrophobic surface characteristics by injection molding

    Science.gov (United States)

    Zhou, Mingyong; Xiong, Xiang; Jiang, Bingyan; Weng, Can

    2018-01-01

    Polymer products with micro/nano-structures have excellent mechanical and optical properties, chemical resistance, and other advantages. Injection molding is one of the most potential techniques to fabricate polymer products with micro/nano-structures artificially in large numbers. In this study, a surface approach to fabricate high aspect ratio nanopillars and micro/nano combined structures was presented. Mold insert with micropillar arrays and nanopillars on its surface was prepared by combing anodic aluminum oxide (AAO) template and etched plate. Anti-sticking modification was done on the template to realize a better demolding quality. The influences of mold temperature and polymer material on the final replication quality were investigated. The results showed that the final replication quality of high aspect ratio nanopillars was greatly improved as compared with the unprocessed template. Polymer with low elongation at break was not suitable to fabricate structures with high aspect ratio via injection molding. For polypropylene surface, the experimental results of static contact angles were almost consistent with Cassie-Baxter equation. When the mold temperature reached 178 °C, hair-like polycarbonate nanopillars were observed, resulting in an excellent hydrophobic characteristic.

  6. Effects of size reduction on deformation, microstructure, and surface roughness of micro components for micro metal injection molding

    Science.gov (United States)

    Liu, Lin; Wang, Xin-da; Li, Xiang; Qi, Xiao-tong; Qu, Xuan-hui

    2017-09-01

    The fabrication of 17-4PH micro spool mandrils by micro metal injection molding was described here. The effects of size reduction on deformation, microstructure and surface roughness were studied by comparing a ϕ500 μm micro post and a ϕ1.7 mm cylinder after debinding and sintering. Experimental results show that slumping of the micro posts occurred due to a dramatic increase in outlet vapor pressure initiated at the thermal degradation onset temperature and the moment of gravity. Asymmetrical stress distribution within the micro component formed during the cooling stage may cause warping. Prior solvent debinding and adjustment in a thermal debinding scheme were useful for preventing the deformation of the micro components. Smaller grain size and higher micro hardness due to impeded grain growth were observed for the micro posts compared with the ϕ1.7 mm cylinder. Surface roughness increased with distance from the gate of the micro spool mandril due to melt front advancement during mold filling and the ensuing pressure distribution. At each position, surface roughness was dictated by injection molding and increased slightly after sintering.

  7. Surface profiling of lithium with a laser-desorption mass-spectrometer microprobe

    International Nuclear Information System (INIS)

    Bickel, G.A.; Adams, H.M.

    1999-01-01

    A laser-desorption mass-spectrometer microprobe has been developed to profile Li distributions on the crevice surfaces of Cr-plated rolled-joint hubs. A single laser pulse is used to desorb and ionize the surface species followed by detection of Li + in a time-of-flight mass spectrometer. Images of the surface Li distribution are obtained with are solution of <10 μm. These images are directly compared with Li images from the more conventional secondary ion mass spectrometry technique and evaluated with respect to surface topographical features measured by secondary electron microscopy and atomic force microscopy. The laser-desorption images are shown to provide the same qualitative information as that available from secondary ion mass spectrometry. (author)

  8. Exploiting flow injection and sequential injection for trace metal determinations in conjunction with detection by electrothermal atomic absorption spectrometry and inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    Despite their excellent analytical chemical capacities, Electrothermal Atomic Absorption Spectrometry (ETAAS) and Inductively Coupled Plasma Mass Spectrometry (ICPMS), nevertheless, often require suitable pretreatment of the sample material in order to obtain the necessary sensitivity...

  9. The pattern of anthropogenic signal emergence in Greenland Ice Sheet surface mass balance

    NARCIS (Netherlands)

    Fyke, J.G.; Vizcaino, M.; Lipscomb, W.H.

    2014-01-01

    Surface mass balance (SMB) trends influence observed Greenland Ice Sheet (GrIS) mass loss, but the component of these trends related to anthropogenic forcing is unclear. Here we study the simulated spatial pattern of emergence of an anthropogenically derived GrIS SMB signal between 1850 and 2100

  10. Analysis of the lipidated recombinant outer surface protein A from Borrelia burgdorferi by mass spectrometry

    NARCIS (Netherlands)

    Bouchon, B.; Klein, Michele; Bischoff, Rainer; Van Dorsselaer, A.; Roitsch, C.

    1997-01-01

    The outer surface protein A, OspA, from the spirochete Borrelia burgdorferi is a lipoprotein of 25 kDa. The recombinant OspA (rOspA) expressed in Escherichia coli has been purified and analyzed by electrospray mass spectrometry (ESMS). A heterogenous spectrum gave a measured mass of 28,462 +/- 9 Da

  11. Analysis of charge injection and contact resistance as a function of electrode surface treatment in ambipolar polymer transistors

    Science.gov (United States)

    Lee, Seon Jeng; Kim, Chaewon; Jung, Seok-Heon; Di Pietro, Riccardo; Lee, Jin-Kyun; Kim, Jiyoung; Kim, Miso; Lee, Mi Jung

    2018-01-01

    Ambipolar organic field-effect transistors (OFETs) have both of hole and electron enhancements in charge transport. The characteristics of conjugated diketopyrrolopyrrole ambipolar OFETs depend on the metal-contact surface treatment for charge injection. To investigate the charge-injection characteristics of ambipolar transistors, these devices are processed via various types of self-assembled monolayer treatments and annealing. We conclude that treatment by the self-assembled monolayer 1-decanethiol gives the best enhancement of electron charge injection at both 100 and 300 °C annealing temperature. In addition, the contact resistance is calculated by using two methods: One is the gated four-point probe (gFPP) method that gives the voltage drop between channels, and the other is the simultaneous contact resistance extraction method, which extracts the contact resistance from the general transfer curve. We confirm that the gFPP method and the simultaneous extraction method give similar contact resistance, which means that we can extract contact resistance from the general transfer curve without any special contact pattern. Based on these characteristics of ambipolar p- and n-type transistors, we fabricate inverter devices with only one active layer. [Figure not available: see fulltext.

  12. The Role of the North Atlantic Oscillation (NAO) on Recent Greenland Surface Mass Loss and Mass Partitioning

    Science.gov (United States)

    Tedesco, M.; Alexander, P.; Porter, D. F.; Fettweis, X.; Luthcke, S. B.; Mote, T. L.; Rennermalm, A.; Hanna, E.

    2017-12-01

    Despite recent changes in Greenland surface mass losses and atmospheric circulation over the Arctic, little attention has been given to the potential role of large-scale atmospheric processes on the spatial and temporal variability of mass loss and partitioning of the GrIS mass loss. Using a combination of satellite gravimetry measurements, outputs of the MAR regional climate model and reanalysis data, we show that changes in atmospheric patterns since 2013 over the North Atlantic region of the Arctic (NAA) modulate total mass loss trends over Greenland together with the spatial and temporal distribution of mass loss partitioning. For example, during the 2002 - 2012 period, melting persistently increased, especially along the west coast, as a consequence of increased insulation and negative NAO conditions characterizing that period. Starting in 2013, runoff along the west coast decreased while snowfall increased substantially, when NAO turned to a more neutral/positive state. Modeled surface mass balance terms since 1950 indicate that part of the GRACE-period, specifically the period between 2002 and 2012, was exceptional in terms of snowfall over the east and northeast regions. During that period snowfall trend decreased to almost 0 Gt/yr from a long-term increasing trend, which presumed again in 2013. To identify the potential impact of atmospheric patterns on mass balance and its partitioning, we studied the spatial and temporal correlations between NAO and snowfall/runoff. Our results indicate that the correlation between summer snowfall and NAO is not stable during the 1950 - 2015 period. We further looked at changes in patterns of circulation using self organizing maps (SOMs) to identify the atmospheric patterns characterizing snowfall during different periods. We discuss potential implications for past changes and future GCM and RCM simulations.

  13. Surface photometry and mass distributions of spiral galaxies

    International Nuclear Information System (INIS)

    Blackman, C.P.

    1979-01-01

    U, B, V and R surface photometry is presented for the two luminosity class I-II galaxies NGC 1084 and 7331. The reduced profiles of both galaxies have well-defined outer components similar to that described in an earlier paper for NGC 157. The radial variation of M/L has been studied by extrapolating the observed rotation curves. The gross structure and detailed colour and M/L variations for both galaxies are described in terms of the density wave theory of spiral structure, which implies that the rotation curves are not flat at large radii. The outer components of both galaxies are too luminous to form conventional massive haloes. In both galaxies the total luminosity exceeds that expected from their luminosity class. (author)

  14. Geophysical monitoring of near surface CO2 injection at Svelvik - Learnings from the CO2FieldLab experiments.

    Science.gov (United States)

    Querendez, Etor; Romdhane, Anouar; Jordan, Michael; Eliasson, Peder; Grimstad, Alv-Arne

    2014-05-01

    A CO2 migration field laboratory for testing monitoring methods and tools has been established in the glaciofluvial-glaciomarine Holocene deposits of the Svelvik ridge, near Oslo (Norway). At the site, feasibility, sensitivity, acquisition geometry and usefulness of various surface and subsurface monitoring tools are investigated during controlled CO2 injection experiments. In a first stage, a shallow CO2 injection experiment was conducted in September 2011. Approximately 1700 kg of CO2 was injected at 18 m depth below surface in an unconsolidated sand formation. The objectives of this experiment were to (i) detect and, where possible, quantify migrated CO2 concentrations at the surface and very shallow subsurface, (ii) evaluate the sensitivity of the monitoring tools and (iii) study the impact of the vadose zone on observed measurements. Results showed that all deployed monitoring tools (for surface and near-surface gas monitoring, subsurface water monitoring and subsurface geophysical monitoring) where able to detect the presence of CO2 even though the CO2 plume did not migrate vertically as expected in what was thought to be an homogeneous unconsolidated sand structure. The upper part of the site revealed to be more heterogeneous than expected, mainly due to the highly variable lamination and channelling of the morainic sediments and to the presence of pebble and cobble beds sporadically showing throughout the deposits. Building on the learnings from the 18m depth injection experiment, a second experiment is being planned for a deeper injection, at a depth of 65m. Re-processing of the appraisal 2D multi-channel seismic with state-of-the-art processing techniques, like Linear Radon coherent and random noise attenuation and Full Waveform Inversion followed by pre-stack depth migration, corroborate the presence of heterogeneities at the near surface. Based on the re-interpreted seismic sections, a more realistic 3D geomodel, where the complex topography of the site

  15. A radio frequency signal driver for quadrupole used in desktop orthogonal-injection time-of-flight mass spectrometer

    International Nuclear Information System (INIS)

    Guo, Changjuan; Jiang, Zhongyao; Xie, Chunguang; Zhu, Hui; Gao, Wei; Huang, Zhengxu; Cheng, Ping; Fu, Zhong; Zhou, Zhen

    2012-01-01

    According to the demand of home-made spectrometer, a radio frequency (RF) signal driver was developed. This RF signal driver is composed of signal generating circuit, signal amplification circuit and power output circuit, to drive the radio frequency quadrupole (RFQ). The designed RFQ is used to transfer ions generated in atmospheric pressure ion source to a home-made desktop orthogonal-injection time-of-flight mass analyzer. This signal driver is divided into low-frequency part and high-frequency part to support RFQ transferring ions of larger values (i.e., m/z=100–600) and smaller values (i.e., m/z=20–100) respectively. The low-frequency part of the RF signal driver can provide RF signals with resonance frequency of 1.43 MHz, peak to peak voltage V p–p of 0–1080 V, and the high-frequency part can provide RF signals with resonance frequency of 2.05 MHz, peak to peak voltage V p–p of 0–520 V. With the radio frequency signal driver described in this paper, ions in the range m/z 20–600 can be transmitted efficiently by RFQ. -- Highlights: ► According to the demand of home-made TOF MS, a radio frequency (RF) signal driver was developed. ► First, we calculated by the theory to determine the parameters, then based on the calculations designed the RF circuit and built it, finally tested the results. ► Found in practice, the theoretical calculations of the air core coil inductances are very close to the actual results. ► The RF circuit built is cheap, compact, stable, and easy to adjust according to the different needs of the TOF MS.

  16. Effect of Body Mass Index on the Outcome of In-Vitro Fertilization/Intracytoplasmic Sperm Injection in Women

    Directory of Open Access Journals (Sweden)

    Manish Banker

    2017-01-01

    Full Text Available Background: Obesity, a known epidemic, is a leading cause of various reproductive disorders. Association of body mass index (BMI with pregnancy outcomes, either ovarian or endometrial, is controversial and least elucidated. Aim: This study aimed to analyze the effect of BMI on in-vitro fertilization (IVF/intracytoplasmic sperm injection (ICSI outcome in women using self-oocytes, embryos prepared from donor oocytes (DE, or vitrified/frozen embryos (VE obtained from both the SE and DE groups. Materials and Methods: A 9-month retrospective study was conducted on women undergoing IVF/ICSI. The women were grouped according to the World Health Organization classification of BMI (<18.50, 18.50–24.99, 25.00–29.99, and ≥30.00 kg/m2. They were further subcategorized as SE, DE, and VE groups. Ongoing pregnancy rate (OPR was recorded as primary, whereas pregnancy rate (PR, clinical PR (CPR, implantation rate (IR, and clinical abortion rate (CAR were secondary endpoints. Age, number of mature eggs, usable embryos, and embryos transferred were also measured. The data were statistically analyzed using chi-square and analysis of variance. P-value <0.05 was considered statistically significant. Results: OPR was statistically insignificant across all the groups. Secondary outcomes were statistically insignificant in all the groups except in VE, where IR (P = 0.008 and CAR (P = 0.0002 were statically significant. Other parameters were statistically insignificant among all the groups. However, in the SE and VE groups, the mean age was statistically significant (SE, P = 0.0001; VE, P = 0.0191. Conclusion: This study showed marginal/no effect of BMI on oocyte quality/endometrial receptivity and, subsequently, on the pregnancy outcome. However, well-designed, larger prospective studies are needed to clarify the role of BMI in pregnancy outcome in women undergoing IVF/ICSI.

  17. Experimental and Numerical Investigation of the Effect of Process Conditions on Residual Wall Thickness and Cooling and Surface Characteristics of Water-Assisted Injection Molded Hollow Products

    Directory of Open Access Journals (Sweden)

    Hyungpil Park

    2015-01-01

    Full Text Available Recently, water-assisted injection molding was employed in the automobile industry to manufacture three-dimensional hollow tube-type products with functionalities. However, process optimization is difficult in the case of water-assisted injection molding because of the various rheological interactions between the injected water and the polymer. In this study, the boiling phenomenon that occurs because of the high melt temperature when injecting water and the molding characteristics of the hollow section during the water-assisted injection process were analyzed by a water-assisted injection molding analysis. In addition, the changes in the residual wall thickness accompanying changes in the process conditions were compared with the analysis results by considering water-assisted injection molding based on gas-assisted injection molding. Furthermore, by comparing the cooling characteristics and inner wall surface qualities corresponding to the formation of the hollow section by gas and water injections, a water-assisted injection molding technique was proposed for manufacturing hollow products with functionality.

  18. Yttria coating on quartz mould inner surface for fabrication of metal fuel slug using injection casting process

    International Nuclear Information System (INIS)

    Vinod, A.V.; Hemanth Kumar, S.; Manivannan, A.; Muralidaran, P.; Anthonysamy, S.; Sudha, R.

    2016-01-01

    Quartz moulds are used for casting metal alloy of U-Zr slugs by injection casting process. Ceramic (Y 2 O 3 ) coating on inner surface of the quartz mould is provided to avoid silica contamination in the fuel slugs during casting. Experiments were carried out to standardise the coating process and optimising various parameters such as particle size of Y 2 O 3 , choice of suitable binder, method for application of coating, drying and sintering at high temperature to ensure uniformity and strength of coating. Required Coating thickness of ∼40 μm was achieved on a quartz mould of inner diameter of 4.98±0.01mm. Experimental procedure for coating on inner surface of the quartz tubes using yttrium oxide is described in this work. (author)

  19. Fabrication of hierarchical polymer surfaces with superhydrophobicity by injection molding from nature and function-oriented design

    Science.gov (United States)

    Weng, Can; Wang, Fei; Zhou, Mingyong; Yang, Dongjiao; Jiang, Bingyan

    2018-04-01

    A comparison of processes and wettability characteristics was presented for injection molded superhydrophobic polypropylene surfaces from two fabricating strategies. One is the biomimetic replication of patterns from indocalamus leaf in nature. The contact angle of water sitting on this PP surface was measured as 152 ± 2°, with comparable wetting behavior to natural indocalamus leaf surface. The other strategy is the fabrication of superhydrophobic structure by combining methods that produce structures at different length scales. Regarding both the machinability of mold inserts and function-oriented design, three micro-quadrangular arrays and one hierarchical micro-nano cylinder array were designed with the goal of superhydrophobicity. Particularly, a simple approach to the fabrication of hierarchical structures was proposed by combining the anodized plate and the punching plate. The function-oriented design targets as superhydrophobicity were all reached for the designed four structures. The measured contact angles of droplet for these structures were almost consistent with the calculated equilibrium contact angles from thermodynamic analysis. Among them, the contact angle of droplet on the surface of designed hierarchical structure reached about 163° with the sliding angle of 5°, resulting in self-cleaning characteristic. The superhydrophobicity of function-oriented designed polymer surfaces could be modified and controlled, which is exactly the limitation of replicating from natural organisms.

  20. Charge Retention by Monodisperse Gold Clusters on Surfaces Prepared Using Soft Landing of Mass Selected Ions

    Science.gov (United States)

    Johnson, Grant; Priest, Thomas; Laskin, Julia

    2012-02-01

    Monodisperse gold clusters have been prepared on surfaces in different charge states through soft landing of mass-selected ions. Gold clusters were synthesized in methanol solution by reduction of a gold precursor with a weak reducing agent in the presence of a diphosphine capping ligand. Electrospray ionization was used to introduce the clusters into the gas-phase and mass-selection was employed to isolate a single ionic cluster species which was delivered to surfaces at well controlled kinetic energies. Using in-situ time of flight secondary ion mass spectrometry (SIMS) it is demonstrated that the cluster retains its 3+ charge state when soft landed onto the surface of a fluorinated self assembled monolayer on gold. In contrast, when deposited onto carboxylic acid terminated and conventional alkyl thiol surfaces on gold the clusters exhibit larger relative abundances of the 2+ and 1+ charge states, respectively. The kinetics of charge reduction on the surface have been investigated using in-situ Fourier Transform Ion Cyclotron Resonance SIMS. It is shown that an extremely slow interfacial charge reduction occurs on the fluorinated monolayer surface while an almost instantaneous neutralization takes place on the surface of the alkyl thiol monolayer. Our results demonstrate that the size and charge state of small gold clusters on surfaces, both of which exert a dramatic influence on their chemical and physical properties, may be tuned through soft landing of mass-selected ions onto selected substrates.

  1. Flux-surface closure during resistive-MHD simulations of Coaxial Helicity Injection (CHI) in NSTX

    Science.gov (United States)

    Hooper, E. B.; Sovinec, C. R.; Raman, R.; Ebrahimi, Fatima; Menard, J. E.

    2012-10-01

    CHI in STs offers considerable promise for generating startup plasmas, with NSTX experiments demonstrating coupling to Ohmic drive with magnetic flux savings.footnotetextR. Raman et al., Phys. Rev. Letters 104, 095003 (2010). Success in these experiments depends in part on the achievement of flux closure following CHI voltage crowbarring. Flux closure is demonstrated here in whole-device, resistive MHD simulations using the NIMROD code. In axisymmetric plasmas significant closure due to resistive effects requires the injection slot to be narrow (e.g. 4 cm vs. 11 cm) in agreement with experiment. In simulations reduction of the applied injector flux following the crowbar forms an X-point close to the bottom of NSTX that significantly enlarges the closed volume; closure is not seen if the flux is held constant. The physics of closure will be discussed and applied to maximizing the volume. Effects of a background plasma in simulations of flux formation and closure will also be described.

  2. Reduction of Surface Flashover of the Beam Screen of the LHC Injection Kickers

    CERN Document Server

    Barnes, M J; Calatroni, S; Caspers, F; Ducimetière, L; Gomes Namora, V; Mertens, V; Noulibos, R; Taborelli, M; Teissandier, B; Uythoven, J; Weterings, W

    2013-01-01

    The LHC injection kicker magnets include beam screens to shield the ferrite yokes against wake fields resulting from the high intensity beam. The screening is provided by conductors lodged in the inner wall of a ceramic support tube. LHC operation with increasingly higher bunch intensity and short bunch lengths, requires improved ferrite screening. This will be implemented by additional conductors; however these must not compromise the good high-voltage behaviour of the kicker magnets. Extensive studies have been carried out to better satisfy the often conflicting requirements for low beam coupling impedance, fast magnetic field rise-time, ultra-high vacuum and good high voltage behaviour. A new design is proposed which significantly reduces the electric field associated with the screen conductors. Results of high voltage tests are also presented.

  3. Sensitivity of Greenland Ice Sheet surface mass balance to surface albedo parameterization: a study with a regional climate model

    NARCIS (Netherlands)

    van Angelen, J.H.|info:eu-repo/dai/nl/325922470; Lenaerts, J.T.M.|info:eu-repo/dai/nl/314850163; Lhermitte, S.; Fettweis, X.; Kuipers Munneke, P.|info:eu-repo/dai/nl/304831891; van den Broeke, M.R.|info:eu-repo/dai/nl/073765643; van Meijgaard, E.; Smeets, C.J.P.P.|info:eu-repo/dai/nl/191522236

    2012-01-01

    We present a sensitivity study of the surface mass balance (SMB) of the Greenland Ice Sheet, as modeled using a regional atmospheric climate model, to various parameter settings in the albedo scheme. The snow albedo scheme uses grain size as a prognostic variable and further depends on cloud cover,

  4. Californium-252 plasma desorption mass analysis of proteins adsorbed on polymer and modified-polymer surfaces

    International Nuclear Information System (INIS)

    Hill, J.C.

    1987-01-01

    A new Cf-252 plasma desorption mass spectrometer has been built specifically for the analysis of large biomolecules. This mass spectrometer was used to investigate the interactions between proteins adsorbed onto polymer surfaces and how the chemical nature of the polymer surface influences the production of stable, gas-phase molecule ions. Chemical modification of the polymer surfaces was achieved by means of ultra-violet irradiation, resulting in the production of a more hydrophilic surface. Analysis of a series of model compounds adsorbed onto modified and non-modified polymer surfaces indicates that the wettability of the surface is an important influence in the production of stable molecular ions. This information was then utilized to aid in the analysis of lysozyme, myoglobin, and porcine trypsin

  5. Evaluation of flow-injection tandem mass spectrometry for rapid and high-throughput quantitative determination of B vitamins in nutritional supplements.

    Science.gov (United States)

    Bhandari, Deepak; Van Berkel, Gary J

    2012-08-29

    The use of flow-injection electrospray ionization tandem mass spectrometry for rapid and high-throughput mass spectral analysis of selected B vitamins, viz., B1, B2, B3, B5, and B6, in nutritional formulations was demonstrated. A simple and rapid (~5 min) in-tube sample preparation was performed. Automated flow injection introduced 1 μL of the extracts directly into the mass spectrometer ion source without chromatographic separation. Sample-to-sample analysis time was 60 s. Quantitative capabilities of the flow-injection analysis were tested using the method of standard additions and SRM 3280. The quantity determined for each B vitamin in SRM 3280 was within the statistical range provided for the respective certified values. This approach was also applied to two different commercial vitamin supplement tablets and proved to be successful in the quantification of the selected B vitamins, as evidenced by an agreement with the label values and the results obtained using isotope dilution liquid chromatography/mass spectrometry.

  6. Evaluation of Flow-Injection Tandem Mass Spectrometry for Rapid and High-Throughput Quantitative Determination of B-Vitamins in Nutritional Supplements

    Energy Technology Data Exchange (ETDEWEB)

    Bhandari, Deepak [ORNL; Van Berkel, Gary J [ORNL

    2012-01-01

    The use of flow-injection electrospray ionization tandem mass spectrometry for rapid and high-throughput mass spectral analysis of selected B-vitamins, viz. B1, B2, B3, B5, and B6, in nutritional formulations was demonstrated. A simple and rapid (~5 min) in-tube sample preparation was performed by adding extraction solvent to a powdered sample aliquot followed by agitation, centrifugation, and filtration to recover an extract for analysis. Automated flow injection introduced 1 L of the extracts directly into the mass spectrometer ion source without chromatographic separation. Sample-to-sample analysis time was 60 s representing significant improvement over conventional liquid chromatography approaches which typically require 25-45 min, and often require more significant sample preparation procedures. Quantitative capabilities of the flow-injection analysis were tested using the method of standard additions and NIST standard reference material (SRM 3280) multivitamin/multielement tablets. The quantity determined for each B-vitamin in SRM 3280 was within the statistical range provided for the respective certified values. The same sample preparation and analysis approach was also applied to two different commercial vitamin supplement tablets and proved to be successful in the quantification of the selected B-vitamins as evidenced by an agreement with the labels values and the results obtained using isotope dilution liquid chromatography/mass spectrometry.

  7. Experimental investigation on shrinkage and surface replication of injection moulded ceramic parts

    DEFF Research Database (Denmark)

    Islam, Aminul; Giannekas, Nikolaos; Marhöfer, David Maximilian

    2014-01-01

    Ceramic moulded parts are increasingly being used in advanced components and devices due to their unprecedented material and performance attributes. The surface finish, replication quality and material shrinkage are of immense importance for moulded ceramic parts intended for precision applications....... The current paper presents a thorough investigation on the process of ceramic moulding where it systematically characterizes the surface replication and shrinkage behaviours of precision moulded ceramic components. The test parts are moulded from Catamold TZP-A which is Y2O3-stabilised ZrO2 having widespread...... distribution for the moulded ceramic parts is presented....

  8. SEMIC: an efficient surface energy and mass balance model applied to the Greenland ice sheet

    Directory of Open Access Journals (Sweden)

    M. Krapp

    2017-07-01

    Full Text Available We present SEMIC, a Surface Energy and Mass balance model of Intermediate Complexity for snow- and ice-covered surfaces such as the Greenland ice sheet. SEMIC is fast enough for glacial cycle applications, making it a suitable replacement for simpler methods such as the positive degree day (PDD method often used in ice sheet modelling. Our model explicitly calculates the main processes involved in the surface energy and mass balance, while maintaining a simple interface and requiring minimal data input to drive it. In this novel approach, we parameterise diurnal temperature variations in order to more realistically capture the daily thaw–freeze cycles that characterise the ice sheet mass balance. We show how to derive optimal model parameters for SEMIC specifically to reproduce surface characteristics and day-to-day variations similar to the regional climate model MAR (Modèle Atmosphérique Régional, version 2 and its incorporated multilayer snowpack model SISVAT (Soil Ice Snow Vegetation Atmosphere Transfer. A validation test shows that SEMIC simulates future changes in surface temperature and surface mass balance in good agreement with the more sophisticated multilayer snowpack model SISVAT included in MAR. With this paper, we present a physically based surface model to the ice sheet modelling community that is general enough to be used with in situ observations, climate model, or reanalysis data, and that is at the same time computationally fast enough for long-term integrations, such as glacial cycles or future climate change scenarios.

  9. ac electrokinetic micropumps: The effect of geometrical confinement, Faradaic current injection, and nonlinear surface capacitance

    DEFF Research Database (Denmark)

    Olesen, Laurits Højgaard; Bruus, Henrik; Ajdari, A.

    2006-01-01

    therefore extend the latter theories to account for three experimentally relevant effects: (i) vertical confinement of the pumping channel, (ii) Faradaic currents from electrochemical reactions at the electrodes, and (iii) nonlinear surface capacitance of the Debye layer. We report here that these effects...... indeed affect the pump performance in a way that we can rationalize by physical arguments....

  10. Two-component injection moulding simulation of ABS-POM micro structured surfaces

    DEFF Research Database (Denmark)

    Tosello, Guido; Hansen, Hans Nørgaard; Islam, Aminul

    2013-01-01

    a pair of thermoplastic materials (ABS and POM) were conducted. Three dimensional process simulations based on the finite element method have been performed to explore the capability of predicting filling pattern shape at component-level and surface micro feature-level in a polymer/polymer overmoulding...

  11. Evaluation of errors for mass-spectrometric analysis with surface-ionization type mass-spectrometer (statistical evaluation of mass-discrimination effect)

    International Nuclear Information System (INIS)

    Wada, Y.

    1981-01-01

    The surface-ionization type mass-spectrometer is widely used as an apparatus for quality assurance, accountability and safeguarding of nuclear materials, and for this analysis it has become an important factor to statistically evaluate an analytical error which consists of a random error and a systematic error. The major factor of this systematic error was the mass-discrimination effect. In this paper, various assays for evaluating the factor of variation on the mass-discrimination effect were studied and the data obtained were statistically evaluated. As a result of these analyses, it was proved that the factor of variation on the mass-discrimination effect was not attributed to the acid concentration of sample, sample size on the filament and supplied voltage for a multiplier, but mainly to the filament temperature during the mass-spectrometric analysis. The mass-discrimination effect values β which were usually calculated from the measured data of uranium, plutonium or boron isotopic standard sample were not so significant dependently of the difference of U-235, Pu-239 or B-10 isotopic abundance. Furthermore, in the case of U and Pu, measurement conditions and the mass range of these isotopes were almost similar, and these values β were not statistically significant between U and Pu. On the other hand, the value β for boron was about a third of the value β for U or Pu, but compared with the coefficient of the correction on the mass-discrimination effect for the difference of mass-number, ΔM, these coefficient values were almost the same among U, Pu, and B.As for the isotopic analysis error of U, Pu, Nd and B, it was proved that the isotopic abundance of these elements and the isotopic analysis error were in a relationship of quadratic curves on a logarithmic-logarithmic scale

  12. Rapid Quantitative Analysis of Multiple Explosive-Compound Classes on a Single Instrument via Flow-Injection Analysis Tandem Mass Spectrometry

    Science.gov (United States)

    2017-03-20

    on a Single In‐ strument via Flow‐Injection Analysis Tandem Mass  Spectrometry   Alla Ostrinskaya, Roderick R. Kunz, Michelle Clark, Rich P...alla.ostrinskaya@ll.mit.edu    ABSTRACT: A flow injection analysis (FIA) tandem mass spectrometry (MSMS) method was developed for rapid quantita- tive analysis of...and has redundant detection channels for reduced  error   rates necessary  for probative use,  (b)  is more  rapid  than existing methods to allow for

  13. Microporous Titanium through Metal Injection Moulding of Coarse Powder and Surface Modification by Plasma Oxidation

    Directory of Open Access Journals (Sweden)

    Mohammed Menhal Shbeh

    2017-01-01

    Full Text Available Titanium is one of the most attractive materials for biomedical applications due to having excellent biocompatibility accompanied by good corrosion resistance. One popular processing technique for Ti is Metal Injection Moulding (MIM. However, there are several issues associated with the use of this technique, such as the high cost of the fine powder used, the high level of contamination and consequent alteration to material properties, as well as the large volume shrinkage that occurs during sintering. In this study, the use of a relatively coarse Ti powder with a mean particle size of 75 μm to process Ti parts with the potential for biomedical applications by MIM will be examined, compared to a commercial Ti feedstock, and subsequently coated using Plasma Electrolytic Oxidation (PEO. The results show that samples produced with the coarse powder shrink 35% less and have a relative density 14% less with an average pore size three-times larger than that of the commercial feedstock. This helps increase the potential competitiveness of MIM in the production of biomedical parts, as it reduces cost, shrinkage and results in more intentionally-induced micropores, such as are desired for biomedical implants. PEO treatment of the samples yields a thick rough coating comprised of a mixture of rutile and anatase with interconnected microporous channels and openings resembling the mouth of a volcanic crater.

  14. On the Changes in Lift of Hydrofoils Due to Surface Injections of Polymer Additives

    Science.gov (United States)

    1978-02-01

    no aIn thom ease of 0.l vox ’-trtd ing theo 110e- ativo I’votttro -paks . Also, thet~o eu dCt’tt.!o iva fe e on tlke t’oil’ .n e 00 I’蜳 ý .0k4 01...hydrofoil chord, c.. In -Equation 133 tho .posoitivo -ig applies to tho uipper surface ou, the hydrofoil Wh11i tho.1wk~ ativo pitgn applies to tho lower

  15. Attractor hopping between polarization dynamical states in a vertical-cavity surface-emitting laser subject to parallel optical injection

    Science.gov (United States)

    Denis-le Coarer, Florian; Quirce, Ana; Valle, Angel; Pesquera, Luis; Rodríguez, Miguel A.; Panajotov, Krassimir; Sciamanna, Marc

    2018-03-01

    We present experimental and theoretical results of noise-induced attractor hopping between dynamical states found in a single transverse mode vertical-cavity surface-emitting laser (VCSEL) subject to parallel optical injection. These transitions involve dynamical states with different polarizations of the light emitted by the VCSEL. We report an experimental map identifying, in the injected power-frequency detuning plane, regions where attractor hopping between two, or even three, different states occur. The transition between these behaviors is characterized by using residence time distributions. We find multistability regions that are characterized by heavy-tailed residence time distributions. These distributions are characterized by a -1.83 ±0.17 power law. Between these regions we find coherence enhancement of noise-induced attractor hopping in which transitions between states occur regularly. Simulation results show that frequency detuning variations and spontaneous emission noise play a role in causing switching between attractors. We also find attractor hopping between chaotic states with different polarization properties. In this case, simulation results show that spontaneous emission noise inherent to the VCSEL is enough to induce this hopping.

  16. Monitoring the on-surface synthesis of graphene nanoribbons by mass spectrometry

    KAUST Repository

    Zhang, Wen

    2017-06-14

    We present a mass spectrometric approach to monitor and characterize the intermediates of graphene nanoribbon (GNR) formation by chemical vapor deposition (CVD) on top of Au(111) surfaces. Information regarding the repeating units, lengths, and termini can be obtained directly from the surface sample by a modified matrix assisted laser desorption/ionization (MALDI) method. The mass spectrometric results reveal ample oxidative side reactions under CVD conditions which can, however, be diminished drastically by introduction of protective H2 gas at ambient pressure. Simultaneously, addition of hydrogen extends the lengths of the oligophenylenes and thus the final GNRs. Moreover, the prematurely formed cyclodehydrogenation products during the oligomer growth can be assigned by the mass spectrometric method. The obtained mechanistic insights provide valuable information for optimizing and upscaling the bottom-up fabrication of GNRs. Given the important role of GNRs as semiconductors, the mass spectrometric characterization provides a readily available tool to improve and characterize their structural perfection.

  17. Paint Spray Mass Spectrometry for the Detection of Additives from Polymers on Conducting Surfaces

    OpenAIRE

    Martin R. L. Paine; Philip J. Barker; Stephen J. Blanksby

    2012-01-01

    Paint Spray is developed as a direct sampling ionisation method for mass spectrometric analysis of additives in polymer-based surface coatings. The technique simply involves applying an external high voltage (5 kV) to the wetted sample placed in front of the mass spectrometer inlet and represents a much simpler ionisation technique compared to those currently available.The capabilities of Paint Spray are demonstrated herein with the detection of four commercially available hindered amine ligh...

  18. Circular polarization switching and bistability in an optically injected 1300 nm spin-vertical cavity surface emitting laser

    Energy Technology Data Exchange (ETDEWEB)

    Alharthi, S. S., E-mail: ssmalh@essex.ac.uk; Henning, I. D.; Adams, M. J. [School of Computer Science and Electronic Engineering, University of Essex, Wivenhoe Park, Colchester CO4 3SQ (United Kingdom); Hurtado, A. [School of Computer Science and Electronic Engineering, University of Essex, Wivenhoe Park, Colchester CO4 3SQ (United Kingdom); Institute of Photonics, Physics Department, University of Strathclyde, Wolfson Centre, 106 Rottenrow East, Glasgow G4 0NW, Scotland (United Kingdom); Korpijarvi, V.-M.; Guina, M. [Optoelectronics Research Centre (ORC), Tampere University of Technology, P.O. Box 692, FIN-33101 Tampere (Finland)

    2015-01-12

    We report the experimental observation of circular polarization switching (PS) and polarization bistability (PB) in a 1300 nm dilute nitride spin-vertical cavity surface emitting laser (VCSEL). We demonstrate that the circularly polarized optical signal at 1300 nm can gradually or abruptly switch the polarization ellipticity of the spin-VCSEL from right-to-left circular polarization and vice versa. Moreover, different forms of PS and PB between right- and left-circular polarizations are observed by controlling the injection strength and the initial wavelength detuning. These results obtained at the telecom wavelength of 1300 nm open the door for novel uses of spin-VCSELs in polarization sensitive applications in future optical systems.

  19. Modelling the deformations during the manufacturing of nanostructures on non-planar surfaces for injection moulding tool inserts

    DEFF Research Database (Denmark)

    Sonne, M. R.; Cech, J.; Pranov, H.

    2016-01-01

    This paper presents a new manufacturing process for transferring nanostructures from a glass wafer to a curved aluminium insert for polymer injection moulding. A nanostructure consisting of sinusoidal cross-gratings with a period of 426 nm is successfully transferred to hemispheres with different...... radii via an embossing process. The embossing is done into a glass-like resist called HSQ, using a 50 μm thick nickel foil, manufactured with electroforming. During the imprinting process the nickel foil is stretched due to the curved surface of the aluminium substrate and it is experimentally possible...... to characterize this stretch by counting the periods of the cross-gratings via SEM characterization. A numerical model for simulating the deformation of the nickel foil during nanoimprint is also developed, utilizing non-linear material and geometrical behaviour. Good agreement between measured and numerically...

  20. Volumes, Masses, and Surface Areas for Shippingport LWBR Spent Nuclear Fuel in a DOE SNF Canister

    International Nuclear Information System (INIS)

    J.W. Davis

    1999-01-01

    The purpose of this calculation is to estimate volumes, masses, and surface areas associated with (a) an empty Department of Energy (DOE) 18-inch diameter, 15-ft long spent nuclear fuel (SNF) canister, (b) an empty DOE 24-inch diameter, 15-ft long SNF canister, (c) Shippingport Light Water Breeder Reactor (LWBR) SNF, and (d) the internal basket structure for the 18-in. canister that has been designed specifically to accommodate Seed fuel from the Shippingport LWBR. Estimates of volumes, masses, and surface areas are needed as input to structural, thermal, geochemical, nuclear criticality, and radiation shielding calculations to ensure the viability of the proposed disposal configuration

  1. Heat Transfer and Mass Diffusion in Nanofluids over a Moving Permeable Convective Surface

    Directory of Open Access Journals (Sweden)

    Muhammad Qasim

    2013-01-01

    Full Text Available Heat transfer and mass diffusion in nanofluid over a permeable moving surface are investigated. The surface exhibits convective boundary conditions and constant mass diffusion. Effects of Brownian motion and thermophoresis are considered. The resulting partial differential equations are reduced into coupled nonlinear ordinary differential equations using suitable transformations. Shooting technique is implemented for the numerical solution. Velocity, temperature, and concentration profiles are analyzed for different key parameters entering into the problem. Performed comparative study shows an excellent agreement with the previous analysis.

  2. Injection moulding antireflective nanostructures

    DEFF Research Database (Denmark)

    Christiansen, Alexander Bruun; Clausen, Jeppe Sandvik; Mortensen, N. Asger

    2014-01-01

    in an injection moulding process, to fabricate the antireflective surfaces. The cycle-time was 35 s. The injection moulded structures had a height of 125 nm, and the visible spectrum reflectance of injection moulded black polypropylene surfaces was reduced from 4.5±0.5% to 2.5±0.5%. The gradient of the refractive...

  3. Injection moulding antireflective nanostructures

    DEFF Research Database (Denmark)

    Christiansen, Alexander Bruun; Clausen, Jeppe Sandvik; Mortensen, N. Asger

    in an injection moulding process, to fabricate the antireflective surfaces. The cycle-time was 35 s. The injection moulded structures had a height of 125 nm, and the visible spectrum reflectance of injection moulded black polypropylene surfaces was reduced from 4.5±0.5% to 2.5±0.5%. The gradient of the refractive...

  4. Rapid Quantitation of Ascorbic and Folic Acids in SRM 3280 Multivitamin/Multielement Tablets using Flow-Injection Tandem Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Bhandari, Deepak [ORNL; Kertesz, Vilmos [ORNL; Van Berkel, Gary J [ORNL

    2013-01-01

    RATIONALE: Ascorbic acid (AA) and folic acid (FA) are water-soluble vitamins and are usually fortified in food and dietary supplements. For the safety of human health, proper intake of these vitamins is recommended. Improvement in the analysis time required for the quantitative determination of these vitamins in food and nutritional formulations is desired. METHODS: A simple and fast (~5 min) in-tube sample preparation was performed, independently for FA and AA, by mixing extraction solvent with a powdered sample aliquot followed by agitation, centrifugation, and filtration to recover an extract for analysis. Quantitative detection was achieved by flow-injection (1 L injection volume) electrospray ionization tandem mass spectrometry (ESI-MS/MS) in negative ion mode using the method of standard addition. RESULTS: Method of standard addition was employed for the quantitative estimation of each vitamin in a sample extract. At least 2 spiked and 1 non-spiked sample extract were injected in triplicate for each quantitative analysis. Given an injection-to-injection interval of approximately 2 min, about 18 min was required to complete the quantitative estimation of each vitamin. The concentration values obtained for the respective vitamins in the standard reference material (SRM) 3280 using this approach were within the statistical range of the certified values provided in the NIST Certificate of Analysis. The estimated limit of detections of FA and AA were 13 and 5.9 ng/g, respectively. CONCLUSIONS: Flow-injection ESI-MS/MS was successfully applied for the rapid quantitation of FA and AA in SRM 3280 multivitamin/multielement tablets.

  5. Charge retention by gold clusters on surfaces prepared using soft landing of mass selected ions.

    Science.gov (United States)

    Johnson, Grant E; Priest, Thomas; Laskin, Julia

    2012-01-24

    Monodisperse gold clusters have been prepared on surfaces in different charge states through soft landing of mass-selected ions. Ligand-stabilized gold clusters were prepared in methanol solution by reduction of chloro(triphenylphosphine)gold(I) with borane tert-butylamine complex in the presence of 1,3-bis(diphenylphosphino)propane. Electrospray ionization was used to introduce the clusters into the gas phase, and mass selection was employed to isolate a single ionic cluster species (Au(11)L(5)(3+), L = 1,3-bis(diphenylphosphino)propane), which was delivered to surfaces at well-controlled kinetic energies. Using in situ time-of-flight secondary ion mass spectrometry (TOF-SIMS), it is demonstrated that the Au(11)L(5)(3+) cluster retains its 3+ charge state when soft landed onto the surface of a 1H,1H,2H,2H-perfluorodecanethiol self-assembled monolayer (FSAM) on gold. In contrast, when deposited onto 16-mercaptohexadecanoic acid (COOH-SAM) and 1-dodecanethiol (HSAM) surfaces on gold, the clusters exhibit larger relative abundances of the 2+ and 1+ charge states, respectively. The kinetics of charge reduction on the FSAM and HSAM surfaces are investigated using in situ Fourier transform ion cyclotron resonance (FT-ICR) SIMS. It is shown that an extremely slow interfacial charge reduction occurs on the FSAM surface while an almost instantaneous neutralization takes place on the surface of the HSAM. Our results demonstrate that the size and charge state of small gold clusters on surfaces, both of which exert a dramatic influence on their chemical and physical properties, may be tuned through soft landing of mass-selected ions onto carefully selected substrates. © 2011 American Chemical Society

  6. Secondary ions mass spectrometric signal enhancement of peptides on enlarged-gold nanoparticle surfaces.

    Science.gov (United States)

    Kim, Young-Pil; Lee, Tae Geol

    2012-06-05

    A high surface coverage of gold nanoparticles (AuNPs) is a prerequisite for enhancing the peptide signal intensity in time-of-flight secondary ion mass spectrometry (TOF-SIMS). Here, we demonstrate the TOF-SIMS signal amplification of peptides on a surface by enlarging surface-confined AuNPs using the NH(2)OH/Au(3+) seeding method. Because of the increased surface area and spherical structure of the Au, the SIMS intensity of the peptides became significantly enhanced on the enlarged-AuNPs surface, especially at high concentrations of peptide solution (>10 μM), compared to that of the bare gold surface or submonolyer of AuNPs. We are confident that this will be a useful method for diagnosis and bioassay with high sensitivity in a label-free manner.

  7. Surface topography of cylindrical gear wheels after smoothing in abrasive mass, honing and shot peening

    International Nuclear Information System (INIS)

    Michalski, J; Pawlus, P; Zelasko, W

    2011-01-01

    The present paper presents the analysis of surface topography of gear teeth as the result of final machining processes. Teeth of multiple cylindrical gears shaped by grinding were smoothed in abrasive mass, honed or shot peened. The measurement of gears were made using coordinate measuring machine and 3D surface topography stylus instrument. The following deviations were studied; pitch deviation, total pitches deviations, variation of teeth thickness and deviation of gear radial run-out. Changes in teeth surface topography during machining process were determined. 3D surface topography parameters, surface directionality as well as areal autocorrelation and power spectral density functions were taken into consideration. As the results of the analysis, the best surface topography with regard to gear operational properties was recommended.

  8. Determination of human-use pharmaceuticals in filtered water by direct aqueous injection: high-performance liquid chromatography/tandem mass spectrometry

    Science.gov (United States)

    Furlong, Edward T.; Noriega, Mary C.; Kanagy, Christopher J.; Kanagy, Leslie K.; Coffey, Laura J.; Burkhardt, Mark R.

    2014-01-01

    This report describes a method for the determination of 110 human-use pharmaceuticals using a 100-microliter aliquot of a filtered water sample directly injected into a high-performance liquid chromatograph coupled to a triple-quadrupole tandem mass spectrometer using an electrospray ionization source operated in the positive ion mode. The pharmaceuticals were separated by using a reversed-phase gradient of formic acid/ammonium formate-modified water and methanol. Multiple reaction monitoring of two fragmentations of the protonated molecular ion of each pharmaceutical to two unique product ions was used to identify each pharmaceutical qualitatively. The primary multiple reaction monitoring precursor-product ion transition was quantified for each pharmaceutical relative to the primary multiple reaction monitoring precursor-product transition of one of 19 isotope-dilution standard pharmaceuticals or the pesticide atrazine, using an exact stable isotope analogue where possible. Each isotope-dilution standard was selected, when possible, for its chemical similarity to the unlabeled pharmaceutical of interest, and added to the sample after filtration but prior to analysis. Method performance for each pharmaceutical was determined for reagent water, groundwater, treated drinking water, surface water, treated wastewater effluent, and wastewater influent sample matrixes that this method will likely be applied to. Each matrix was evaluated in order of increasing complexity to demonstrate (1) the sensitivity of the method in different water matrixes and (2) the effect of sample matrix, particularly matrix enhancement or suppression of the precursor ion signal, on the quantitative determination of pharmaceutical concentrations. Recovery of water samples spiked (fortified) with the suite of pharmaceuticals determined by this method typically was greater than 90 percent in reagent water, groundwater, drinking water, and surface water. Correction for ambient environmental

  9. Body mass index and active range of motion exercise treatment after intra-articular injection in adhesive capsulitis

    Directory of Open Access Journals (Sweden)

    Hsi-Hsien Lin

    2013-04-01

    Conclusion: Active range of motion exercise after an intra-articular injection of corticosteroid and lidocaine improved pain and functional outcome at 8 weeks in normal-weight (BMI < 25 kg/m2 patients with primary adhesive capsulitis. Manipulation under anesthesia may be considered a priority in overweight patients.

  10. Fast gas chromatographic residue analysis in animal feed using split injection and atmospheric pressure chemical ionisation tandem mass spectrometry

    NARCIS (Netherlands)

    Tienstra, M.; Portolés, T.; Hernandez, F.; Mol, J.G.J.

    2015-01-01

    Significant speed improvement for instrumental runtime would make GC–MS much more attractive for determination of pesticides and contaminants and as complementary technique to LC–MS. This was the trigger to develop a fast method (time between injections less than 10 min) for the determination of

  11. Basin-scale heterogeneity in Antarctic precipitation and its impact on surface mass variability

    Directory of Open Access Journals (Sweden)

    J. Fyke

    2017-11-01

    Full Text Available Annually averaged precipitation in the form of snow, the dominant term of the Antarctic Ice Sheet surface mass balance, displays large spatial and temporal variability. Here we present an analysis of spatial patterns of regional Antarctic precipitation variability and their impact on integrated Antarctic surface mass balance variability simulated as part of a preindustrial 1800-year global, fully coupled Community Earth System Model simulation. Correlation and composite analyses based on this output allow for a robust exploration of Antarctic precipitation variability. We identify statistically significant relationships between precipitation patterns across Antarctica that are corroborated by climate reanalyses, regional modeling and ice core records. These patterns are driven by variability in large-scale atmospheric moisture transport, which itself is characterized by decadal- to centennial-scale oscillations around the long-term mean. We suggest that this heterogeneity in Antarctic precipitation variability has a dampening effect on overall Antarctic surface mass balance variability, with implications for regulation of Antarctic-sourced sea level variability, detection of an emergent anthropogenic signal in Antarctic mass trends and identification of Antarctic mass loss accelerations.

  12. Characterization and analysis of micro channels and sub-micron surface roughness of injection moulded microfluidic systems using optical metrology

    DEFF Research Database (Denmark)

    Tosello, Guido; Marinello, Francesco; Hansen, Hans Nørgaard

    2012-01-01

    Precision injection moulding of miniaturized products with micro features such as channels for microfluidic applications poses the greatest challenges in terms of tooling technology and process optimization. The injection moulding process window of polypropylene was validated using a metrological...... temperature, injection speed)....

  13. An experimental study on mass loading of soil particles on plant surfaces

    International Nuclear Information System (INIS)

    Li, J.; Gerzabek, M.H.; Mueck, K.

    1994-03-01

    Radionuclide contaminated soil adhered to plant surfaces can contribute to human ingestion dose. To determine this contribution, a method of 46 Sc neutron activation analysis was established and tested, by which a detection limit of 0.05 mg soil per g dry plant biomass can be obtained. In the field and greenhouse experiment the mass loading of soil on ryegrass (Lolium perenne L.) and broad bean (Vicia faba L.) was investigated and the contribution from rainsplash and wind erosion were evaluated separately. Soil retained on plant surfaces in field conditions in Seibersdorf/Austria was 5.77 ± 1.44 mg soil per g dry plant for ryegrass and 9.51 ± 0.73 mg soil per g dry plant for broad bean. Estimates of contribution from rainsplash and wind erosion to soil contamination of plant during the experimental period are 68 % and 32 % for broadbean, 47 % and 53 % for ryegrass, respectively. Mass loading results from field studies indicate that soil adhesion on plant surfaces can contribute up to 23 % of plant 137 Cs contamination, the transfer factors modified by mass loading decline differently, depending on 137 Cs concentration of the soil and the soil mass adhered to plant surfaces. (authors)

  14. Ambient Surface Analysis of Organic Monolayers using Direct Analysis in Real Time Orbitrap Mass Spectrometry

    NARCIS (Netherlands)

    Manova, R.K.; Joshi, S.; Debrassi, A.; Bhairamadgi, N.S.; Roeven, E.; Gagnon, J.; Tahir, M.N.; Claassen, F.W.; Scheres, L.M.W.; Wennekes, T.; Schroën, C.G.P.H.; Beek, van T.A.; Zuilhof, H.; Nielen, M.W.F.

    2014-01-01

    A better characterization of nanometer-thick organic layers (monolayers) as used for engineering surface properties, biosensing, nanomedicine, and smart materials will widen their application. The aim of this study was to develop direct analysis in real time high-resolution mass spectrometry

  15. An experimental study on mass loading of soil particles on plant surfaces

    International Nuclear Information System (INIS)

    Li, J. G.; Gerzabek, M. H.; Mueck, K.

    1994-01-01

    Radionuclide contaminated soil adhered to plant surfaces can contribute to human ingestion dose. To determine this contribution, a method of 46 Sc neutron activation analysis was established and tested, by which a detection limit of 0.05 mg soil per g dry plant biomass can be obtained. In the field and greenhouse experiment the mass loading of soil on ryegrass (Lolium perenne L.) and broadbean (Vicia faba L.) was investigated and the contribution from rainsplash and wind erosion were evaluated separately. Soil retained on plant surfaces in field conditions in Seibersdorf/Austria was 5.77 ± 1.44 mg soil per g dry plant for ryegrass and 9.51 ± 0.73 mg soil per g dry plant for broadbean. Estimates of contribution from rainsplash and wind erosion to soil contamination of plants during the experimental period are 68 % and 32 % for broadbean 47 % and 53 % for ryegrass respectively. Mass loading results from field studies indicate that soil adhesion on plant surfaces can contribute up to 23 % of plant 137 Cs contamination, the transfer factors modified by mass loading decline differently, depending on 137 Cs concentration of the soil and the soil mass adhered to plant surfaces. (author)

  16. The Minimum-Mass Surface Density of the Solar Nebula using the Disk Evolution Equation

    Science.gov (United States)

    Davis, Sanford S.

    2005-01-01

    The Hayashi minimum-mass power law representation of the pre-solar nebula (Hayashi 1981, Prog. Theo. Phys.70,35) is revisited using analytic solutions of the disk evolution equation. A new cumulative-planetary-mass-model (an integrated form of the surface density) is shown to predict a smoother surface density compared with methods based on direct estimates of surface density from planetary data. First, a best-fit transcendental function is applied directly to the cumulative planetary mass data with the surface density obtained by direct differentiation. Next a solution to the time-dependent disk evolution equation is parametrically adapted to the planetary data. The latter model indicates a decay rate of r -1/2 in the inner disk followed by a rapid decay which results in a sharper outer boundary than predicted by the minimum mass model. The model is shown to be a good approximation to the finite-size early Solar Nebula and by extension to extra solar protoplanetary disks.

  17. Higher surface mass balance of the Greenland ice sheet revealed by high-resolution climate modeling

    NARCIS (Netherlands)

    Ettema, J.|info:eu-repo/dai/nl/304831913; van den Broeke, M.R.|info:eu-repo/dai/nl/073765643; van Meijgaard, E.; van de Berg, W.J.|info:eu-repo/dai/nl/304831611; Bamber, Jonathan L.; Box, J.E.; Bales, R.C.

    2009-01-01

    High-resolution (∼11 km) regional climate modeling shows total annual precipitation on the Greenland ice sheet for 1958–2007 to be up to 24% and surface mass balance up to 63% higher than previously thought. The largest differences occur in coastal southeast Greenland, where the much higher

  18. Future climate warming increases Greenland ice sheet surface mass balance variability

    NARCIS (Netherlands)

    Fyke, J.G.; Vizcaino, M.; Lipscomb, W.; Price, S.

    2014-01-01

    The integrated surface mass balance (SMB) of the Greenland ice sheet (GrIS) has large interannual variability. Long-term future changes to this variability will affect GrIS dynamics, freshwater fluxes, regional oceanography, and detection of changes in ice volume trends. Here we analyze a simulated

  19. Greenland ice sheet surface mass balance: evaluating simulations and making projections with regional climate models

    NARCIS (Netherlands)

    Rae, J.G.L.; Aðalgeirsdóttir, G.; Edwards, T.L.; Fettweis, X.; Gregory, J.M.; Hewitt, H.T.; Lowe, J.A.; Lucas-Picher, P.; Mottram, R.H.; Payne, A.J.; Ridley, J.K.; Shannon, S.R.; van de Berg, W.J.|info:eu-repo/dai/nl/304831611; van de Wal, R.S.W.|info:eu-repo/dai/nl/101899556; van den Broeke, M.R.|info:eu-repo/dai/nl/073765643

    2012-01-01

    Four high-resolution regional climate models (RCMs) have been set up for the area of Greenland, with the aim of providing future projections of Greenland ice sheet surface mass balance (SMB), and its contribution to sea level rise, with greater accuracy than is possible from coarser-resolution

  20. Dynamics and mass accommodation of HCl molecules on sulfuric acid-water surfaces.

    Science.gov (United States)

    Behr, P; Scharfenort, U; Ataya, K; Zellner, R

    2009-09-28

    A molecular beam technique has been used to study the dynamics and mass accommodation of HCl molecules in collision with sulfuric acid-water surfaces. The experiments were performed by directing a nearly mono-energetic beam of HCl molecules onto a continuously renewed liquid film of 54-76 wt% sulfuric acid at temperatures between 213 K and 243 K. Deuterated sulfuric acid was used to separate sticking but non-reactive collisions from those that involved penetration through the phase boundary followed by dissociation and recombination with D+. The results indicate that the mass accommodation of HCl on sulfuric acid-water surfaces decreases sharply with increasing acidity over the concentration range 54-76 wt%. Using the capillary wave theory of mass accommodation this effect is explained by a change of the surface dynamics. Regarding the temperature dependence it is found that the mass accommodation of HCl increases with increasing temperature and is limited by the bulk phase viscosity and driven by the restoring forces of the surface tension. These findings imply that under atmospheric conditions the uptake of HCl from the gas phase depends crucially on the bulk phase parameters of the sulfuric acid aerosol.

  1. Aeolian vertical mass flux profiles above dry and moist sandy beach surfaces

    Science.gov (United States)

    Rotnicka, Joanna

    2013-04-01

    The vertical distribution of aeolian mass flux was investigated in a natural beach environment. Field experiments conducted on the beach of the Łeba Barrier, southern Baltic coast, Poland, measured the sand transport rate and the vertical mass flux distribution above dry rippled sand and a moist flat sandy surface. The experiments were intended to show the changes in the vertical distribution of sand with changing wind speed. All the data represent saturated flux conditions. Sand transport was measured using 0.5 m-high vertically segmented passive sand traps, while the wind speed and direction were monitored at 1 m elevation. The obtained dataset comprises 65 measurements on dry surfaces and 51 measurements on moist sandy surfaces. The sand transport rate above the moist surface was up to 90% higher than above the dry surface for wind speeds of 7-11 m/s, but higher velocities gave smaller differences between the surfaces. The saltation layer was thicker above the moist surface than above the dry surface. All the vertical sand flux profiles are best described by exponential decay functions. Analysis of the normalised flux profiles grouped by wind velocity shows that the fitted curves are less inclined for moist surfaces than dry surfaces. Moreover, the regression coefficients depict a marked trend in which the intercept decreases and the slope increases with increasing wind speed; this indicates that more sand is transported at higher elevations above the bed and less at lower elevations. The proportion of total transport seems to be independent of wind speed at elevations of approximately 35 mm and 50 mm above the dry and moist surfaces, respectively. Differences between the measured- and exponential-fit values of mass flux are particularly distinct close to the bed, where the exponential fit either over- or under-predicts the measured values. Over-predictions occur in weaker winds (up to 6-7 m/s), whereas under-predictions become more pronounced as the wind

  2. Corporal surface as indicator of muscular mass in the adult of the masculine sex

    International Nuclear Information System (INIS)

    Fernandez Vieitez, Jorge Alberto

    2003-01-01

    With the objective of finding out the body surface area equation (BSA, m2) that is most suitable as indicator of musculature because of its higher correlation with the muscle mass (MM,kg), a correlation analysis was made between the MM and the BSA estimated by 11 weight and height-based formulae. Primary weight, height and MM data were obtained from these studies (N=41) in which MM was determined by cadaver dissection or by computerized axial tomography. A remarkable variability was observed in the BSA values estimated by 11 equations (F=59,7; p< 0,05). The correlation coefficients between the body surface estimated by different equations and the muscle mass were statistically significant and very similar. It was concluded that there is no BSA equation that is far better than the rest as muscle mass indicator. Mostellers equation is recommended due to its calculation simplicity

  3. Exploring surface photoreaction dynamics using pixel imaging mass spectrometry (PImMS)

    Science.gov (United States)

    Kershis, Matthew D.; Wilson, Daniel P.; White, Michael G.; John, Jaya John; Nomerotski, Andrei; Brouard, Mark; Lee, Jason W. L.; Vallance, Claire; Turchetta, Renato

    2013-08-01

    A new technique for studying surface photochemistry has been developed using an ion imaging time-of-flight mass spectrometer in conjunction with a fast camera capable of multimass imaging. This technique, called pixel imaging mass spectrometry (PImMS), has been applied to the study of butanone photooxidation on TiO2(110). In agreement with previous studies of this system, it was observed that the main photooxidation pathway for butanone involves ejection of an ethyl radical into vacuum which, as confirmed by our imaging experiment, undergoes fragmentation after ionization in the mass spectrometer. This proof-of-principle experiment illustrates the usefulness and applicability of PImMS technology to problems of interest within the surface science community.

  4. Body surface dosimetry following re-injection of sup 111 In-leucocytes. [Radiation doses to infants from parents injected with sup 111 In-leucocytes

    Energy Technology Data Exchange (ETDEWEB)

    Mountford, P.J.; Coakley, A.J. (Kent and Canterbury Hospital (United Kingdom))

    1989-07-01

    The dose to a young infant cared for by a parent re-injected with {sup 111}In-leucocytes was estimated from the exposure of thermoluminescent dosimeters at five sites on the chest wall of eight patients. The UK Guidance Notes recommend that patients with a residual activity exceeding 20 MBq of {sup 111}In should avoid non-essential contact with children. The results confirmed those of an earlier preliminary study which showed that re-injection of 20 MBq of {sup 111}In-leucocytes to a parent could lead to a close contact dose greater than 1 mSv. It was concluded that the {sup 111}In-leucocyte activity administered to a parent of a young infant should not exceed 10 MBq. (author).

  5. Past and future sea-level change from the surface mass balance of glaciers

    Directory of Open Access Journals (Sweden)

    B. Marzeion

    2012-11-01

    Full Text Available We present estimates of sea-level change caused by the global surface mass balance of glaciers, based on the reconstruction and projection of the surface mass balance of all the individual glaciers of the world, excluding the ice sheets in Greenland and Antarctica. The model is validated using a leave-one-glacier-out cross-validation scheme against 3997 observed surface mass balances of 255 glaciers, and against 756 geodetically observed, temporally integrated volume and surface area changes of 341 glaciers. When forced with observed monthly precipitation and temperature data, the glaciers of the world are reconstructed to have lost mass corresponding to 114 ± 5 mm sea-level equivalent (SLE between 1902 and 2009. Using projected temperature and precipitation anomalies from 15 coupled general circulation models from the Coupled Model Intercomparison Project phase 5 (CMIP5 ensemble, they are projected to lose an additional 148 ± 35 mm SLE (scenario RCP26, 166 ± 42 mm SLE (scenario RCP45, 175 ± 40 mm SLE (scenario RCP60, or 217 ± 47 mm SLE (scenario RCP85 during the 21st century. Based on the extended RCP scenarios, glaciers are projected to approach a new equilibrium towards the end of the 23rd century, after having lost either 248 ± 66 mm SLE (scenario RCP26, 313 ± 50 mm SLE (scenario RCP45, or 424 ± 46 mm SLE (scenario RCP85. Up until approximately 2100, ensemble uncertainty within each scenario is the biggest source of uncertainty for the future glacier mass loss; after that, the difference between the scenarios takes over as the biggest source of uncertainty. Ice mass loss rates are projected to peak 2040 ∼ 2050 (RCP26, 2050 ∼ 2060 (RCP45, 2070 ∼ 2090 (RCP60, or 2070 ∼ 2100 (RCP85.

  6. Nanostructuring steel for injection molding tools

    DEFF Research Database (Denmark)

    Al-Azawi, A.; Smistrup, Kristian; Kristensen, Anders

    2014-01-01

    The production of nanostructured plastic items by injection molding with ridges down to 400 nm in width, which is the smallest line width replicated from nanostructured steel shims, is presented. Here we detail a micro-fabrication method where electron beam lithography, nano-imprint lithography...... and ion beam etching are combined to nanostructure the planar surface of a steel wafer. Injection molded plastic parts with enhanced surface properties, like anti-reflective, superhydrophobic and structural colors can be achieved by micro-and nanostructuring the surface of the steel molds. We investigate...... has been produced by injection molding with good structure transfer fidelity. Thus we have demonstrated that by utilizing well-established fabrication techniques, nanostructured steel shims that are used in injection molding, a technique that allows low cost mass fabrication of plastic items...

  7. Trace analysis of total naphthenic acids in aqueous environmental matrices by liquid chromatography/mass spectrometry-quadrupole time of flight mass spectrometry direct injection.

    Science.gov (United States)

    Brunswick, Pamela; Shang, Dayue; van Aggelen, Graham; Hindle, Ralph; Hewitt, L Mark; Frank, Richard A; Haberl, Maxine; Kim, Marcus

    2015-07-31

    A rapid and sensitive liquid chromatography quadrupole time of flight method has been established for the determination of total naphthenic acid concentrations in aqueous samples. This is the first methodology that has been adopted for routine, high resolution, high throughput analysis of total naphthenic acids at trace levels in unprocessed samples. A calibration range from 0.02 to 1.0μgmL(-1) total Merichem naphthenic acids was validated and demonstrated excellent accuracy (97-111% recovery) and precision (1.9% RSD at 0.02μgmL(-1)). Quantitative validation was also demonstrated in a non-commercial oil sands process water (OSPW) acid extractable organics (AEOs) fraction containing a higher percentage of polycarboxylic acid isomers than the Merichem technical mix. The chromatographic method showed good calibration linearity of ≥0.999 RSQ to 0.005μgmL(-1) total naphthenic acids with a precision <3.1% RSD and a calculated detection limit of 0.0004μgmL(-1) employing Merichem technical mix reference material. The method is well suited to monitoring naturally occurring and industrially derived naphthenic acids (and other AEOs) present in surface and ground waters in the vicinity of mining developments. The advantage of the current method is its direct application to unprocessed environmental samples and to examine natural naphthenic acid isomer profiles. It is noted that where the isomer profile of samples differs from that of the reference material, results should be considered semi-quantitative due to the lack of matching isomer content. The fingerprint profile of naphthenic acids is known to be transitory during aging and the present method has the ability to adapt to monitoring of these changes in naphthenic acid content. The method's total ion scan approach allows for data previously collected to be examined retrospectively for specific analyte mass ions of interest. A list of potential naphthenic acid isomers that decrease in response with aging is proposed

  8. Extending and refining the nuclear mass surface with ISOLTRAP and MISTRAL

    International Nuclear Information System (INIS)

    Lunney, D.; Bollen, G.

    2000-01-01

    Through the nuclear binding energy, the atomic mass gives us important information about nuclear structure. Viewing the ensemble of mass data over the nuclear chart, we can examine the hills and valleys that form this surface and make hypotheses about the effects of certain nuclear configurations. To unveil these effects, mass measurements of very high precision ( -6 ) are required. Two experiments at ISOLDE pursue this effort of nuclear cartography: the tandem Penning trap spectrometer ISOLTRAP and the radiofrequency transmission spectrometer MISTRAL. Between them, the masses of almost 150 nuclides have been measured from stable isotopes to those with half-lives as short as 30 ms. Both experiments rely on good optical properties of a low energy ion beam and are thus well suited to the ISOLDE facility

  9. Pre-column dilution large volume injection ultra-high performance liquid chromatography-tandem mass spectrometry for the analysis of multi-class pesticides in cabbages.

    Science.gov (United States)

    Zhong, Qisheng; Shen, Lingling; Liu, Jiaqi; Yu, Dianbao; Li, Siming; Yao, Jinting; Zhan, Song; Huang, Taohong; Hashi, Yuki; Kawano, Shin-ichi; Liu, Zhaofeng; Zhou, Ting

    2016-04-15

    Pre-column dilution large volume injection (PD-LVI), a novel sample injection technique for reverse phase ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS), was developed in this study. The PD-LVI UHPLC-MS/MS system was designed by slightly modifying the commercial UHPLC-MS/MS equipment with a mixer chamber. During the procedure of PD-LVI, sample solution of 200μL was directly carried by the organic mobile phase to the mixer and diluted with the aqueous mobile phase. After the mixture was introduced to the UHPLC column in a mobile phase of acetonitrile-water (15/85, v/v), the target analytes were stacked on the head of the column until following separation. Using QuEChERS extraction, no additional steps such as solvent evaporation or residue redissolution were needed before injection. The features of PD-LVI UHPLC-MS/MS system were systematically investigated, including the injection volume, the mixer volume, the precondition time and the gradient elution. The efficiency of this approach was demonstrated by direct analysis of 24 pesticides in cabbages. Under the optimized conditions, low limits of detection (0.00074-0.8 ng/kg) were obtained. The recoveries were in the range of 63.3-109% with relative standard deviations less than 8.1%. Compared with common UHPLC-MS/MS technique, PD-LVI UHPLC-MS/MS showed significant advantages such as excellent sensitivity and reliability. The mechanism of PD-LVI was demonstrated to be based on the column-head stacking effect with pre-column dilution. Based on the results, PD-LVI as a simple and effective sample injection technique of reverse phase UHPLC-MS/MS for the analysis of trace analytes in complex samples showed a great promising prospect. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Geographical altitude, size, mass and body surface area in children (1-4 years) in the Province of Jujuy (Argentina).

    Science.gov (United States)

    Román, Estela María; Bejarano, Ignacio Felipe; Alfaro, Emma Laura; Abdo, Guadalupe; Dipierri, José Edgardo

    2015-01-01

    Highland child populations show low growth rates. To evaluate the variation of size, mass and body surface area of Jujenean infants (1-4 years) as a function of geographic altitude. Nutritional status of 8059 healthy infants was determined based on weight and height data; body mass index, ponderal index, body surface area, body surface area/mass and ectomorphy were calculated. Variables were standardized with a provincial mean and WHO references. Data were grouped by age, sex and geographic altitude: Highlands (≥2500 masl) and Lowlands (children differ in size, mass and body surface area based on the geographical altitude and adverse nutritional and socioeconomic factors.

  11. Mass

    International Nuclear Information System (INIS)

    Quigg, Chris

    2007-01-01

    In the classical physics we inherited from Isaac Newton, mass does not arise, it simply is. The mass of a classical object is the sum of the masses of its parts. Albert Einstein showed that the mass of a body is a measure of its energy content, inviting us to consider the origins of mass. The protons we accelerate at Fermilab are prime examples of Einsteinian matter: nearly all of their mass arises from stored energy. Missing mass led to the discovery of the noble gases, and a new form of missing mass leads us to the notion of dark matter. Starting with a brief guided tour of the meanings of mass, the colloquium will explore the multiple origins of mass. We will see how far we have come toward understanding mass, and survey the issues that guide our research today.

  12. Bead Injection Extraction Chromatography using High-capacity Lab-on-Valve as a Front End to Inductively Coupled Plasma Mass Spectrometry for Rapid Urine Radiobioassay

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per

    2013-01-01

    L) incorporated within the LOV processing unit is loaded on-line with a metered amount of disposable extraction chromatographic resin (up to 330 mg of TEVA) through programmable beads transport. Selective capture and purification of plutonium onto the resin beads is then performed by pressure driven flow after......A novel bead injection (BI) extraction chromatographic microflow system exploiting high-capacity lab-on-valve (LOV) platform coupled with inductively coupled plasma mass spectrometric detection is developed for rapid and automated determination of plutonium in human urine. A microconduit (1 m...

  13. A Study of the Geo-Herbalism of Evodiae Fructus Based on a Flow-Injection Mass Spectrometric Fingerprinting Method Combined with Chemometrics

    Directory of Open Access Journals (Sweden)

    Yang Zhao

    2015-02-01

    Full Text Available A flow-injection mass spectrometric (FIMS fingerprinting method in combination with principal component analysis (PCA was used to study the geo-herbalism of Evodiae Fructus (EF samples. Twenty four EF samples from different regions in China were collected and analyzed. The PCA scores plot showed that the samples from Guizhou Province were scattered in different groups, however, most of the samples from other provinces were basically scattered in the same group. Nine characteristic compounds responsible for the classification of the samples were tentatively characterized. These nine compounds might help differentiating EF samples from different regions.

  14. Rapid isolation of biomarkers for compound specific radiocarbon dating using high-performance liquid chromatography and flow injection analysis-atmospheric pressure chemical ionisation mass spectrometry.

    Science.gov (United States)

    Smittenberg, Rienk H; Hopmans, Ellen C; Schouten, Stefan; Sinninghe Damsté, Jaap S

    2002-11-29

    Repeated semi-preparative normal-phase HPLC was performed to isolate selected biomarkers from sediment extracts for radiocarbon analysis. Flow injection analysis-mass spectrometry was used for rapid analysis of collected fractions to evaluate the separation procedure, taking only 1 min per fraction. In this way 100-1000 microg of glycerol dialkyl glycerol tetraethers, sterol fractions and chlorophyll-derived phytol were isolated from typically 100 g of marine sediment, i.e., in sufficient quantities for radiocarbon analysis, without significant carbon isotopic fractionation or contamination.

  15. Development of a Linear Ion Trap Mass Spectrometer (LITMS) Investigation for Future Planetary Surface Missions

    Science.gov (United States)

    Brinckerhoff, W.; Danell, R.; Van Ameron, F.; Pinnick, V.; Li, X.; Arevalo, R.; Glavin, D.; Getty, S.; Mahaffy, P.; Chu, P.; hide

    2014-01-01

    Future surface missions to Mars and other planetary bodies will benefit from continued advances in miniature sensor and sample handling technologies that enable high-performance chemical analyses of natural samples. Fine-scale (approx.1 mm and below) analyses of rock surfaces and interiors, such as exposed on a drill core, will permit (1) the detection of habitability markers including complex organics in association with their original depositional environment, and (2) the characterization of successive layers and gradients that can reveal the time-evolution of those environments. In particular, if broad-based and highly-sensitive mass spectrometry techniques could be brought to such scales, the resulting planetary science capability would be truly powerful. The Linear Ion Trap Mass Spectrometer (LITMS) investigation is designed to conduct fine-scale organic and inorganic analyses of short (approx.5-10 cm) rock cores such as could be acquired by a planetary lander or rover arm-based drill. LITMS combines both pyrolysis/gas chromatograph mass spectrometry (GCMS) of sub-sampled core fines, and laser desorption mass spectrometry (LDMS) of the intact core surface, using a common mass analyzer, enhanced from the design used in the Mars Organic Molecule Analyzer (MOMA) instrument on the 2018 ExoMars rover. LITMS additionally features developments based on the Sample Analysis at Mars (SAM) investigation on MSL and recent NASA-funded prototype efforts in laser mass spectrometry, pyrolysis, and precision subsampling. LITMS brings these combined capabilities to achieve its four measurement objectives: (1) Organics: Broad Survey Detect organic molecules over a wide range of molecular weight, volatility, electronegativity, concentration, and host mineralogy. (2) Organic: Molecular Structure Characterize internal molecular structure to identify individual compounds, and reveal functionalization and processing. (3) Inorganic Host Environment Assess the local chemical

  16. The influence of changes in glacier extent and surface elevation on modeled mass balance

    Directory of Open Access Journals (Sweden)

    F. Paul

    2010-12-01

    Full Text Available Glaciers are widely recognized as unique demonstration objects for climate change impacts, mostly due to the strong change of glacier length in response to small climatic changes. However, glacier mass balance as the direct response to the annual atmospheric conditions can be better interpreted in meteorological terms. When the climatic signal is deduced from long-term mass balance data, changes in glacier geometry (i.e. surface extent and elevation must be considered as such adjustments form an essential part of the glacier reaction to new climatic conditions. In this study, a set of modelling experiments is performed to assess the influence of changes in glacier geometry on mass balance for constant climatic conditions. The calculations are based on a simplified distributed energy/mass balance model in combination with information on glacier extent and surface elevation for the years 1850 and 1973/1985 for about 60 glaciers in the Swiss Alps. The results reveal that over this period about 50–70% of the glacier reaction to climate change (here a one degree increase in temperature is "hidden" in the geometric adjustment, while only 30–50% can be measured as the long-term mean mass balance. For larger glaciers, the effect of the areal change is partly reduced by a lowered surface elevation, which results in a slightly more negative balance despite a potential increase of topographic shading. In view of several additional reinforcement feedbacks that are observed in periods of strong glacier decline, it seems that the climatic interpretation of long-term mass balance data is rather complex.

  17. Application of gas chromatography-surface ionization organic mass spectrometry to forensic toxicology.

    Science.gov (United States)

    Ishii, Akira; Watanabe-Suzuki, Kanako; Seno, Hiroshi; Suzuki, Osamu; Katsumata, Yoshinao

    2002-08-25

    Surface ionization (SI), which consists in the formation of positive and negative ions along the course of thermal desorption of particles from a solid surface, was first applied as a detector for gas chromatography (GC), GC-surface ionization detection (SID); we developed many new sensitive methods for the determination of abused and other drugs by GC-SID. Recently, Fujii has devised a combination of SI and a quadrupole mass spectrometer and named this system a surface ionization organic mass spectrometer (SIOMS), which is highly selective and sensitive for organic compounds containing tertiary amino groups. We have tried to apply this mass spectrometer to forensic toxicological study; so far we have succeeded in determining important drugs-of-abuse and toxic compounds, such as phencyclidine (PCP), pethidine, pentazocine, MPTP and its derivatives from human body fluids with high sensitivity and selectivity. In this review, we describe our recent studies on the application of GC-SIOMS to forensic toxicology. Copyright 2002 Elsevier Science B.V.

  18. Application of »Mass Titration« to Determination of Surface Charge of Metal Oxides

    OpenAIRE

    1998-01-01

    The mass titration method, used for the point of zero charge determination, was extended to the measurement of the surface charge density. The results agree with the common method, which is the acid-base titration of the colloidal suspension. The advantage of mass titration is that one does not need to perform blank titration, instead one simply adds metal oxide powder to the electrolyte aqueous solution of known pH. To cover the pH range above and below the point of zero charge, two experime...

  19. Raman spectroscopic analysis of cyanogenic glucosides in plants: development of a Flow Injection Surface-Enhanced Raman Scatter (FI-SERS) method for determination of cyanide

    DEFF Research Database (Denmark)

    Thygesen, Lisbeth Garbrecht; Jørgensen, Kirsten; Møller, Birger Lindberg

    2004-01-01

    -dried sorghum leaf was also obtained using this instrument. Surface-enhanced Raman Spectroscopy (SERS) was demonstrated to be a more sensitive method that enabled determination of the cyanogenic potential of plant tissue. The SERS method was optimized by flow injection (FI) using a colloidal gold dispersion...... as effluent. Potential problems and pitfalls of the method are discussed....

  20. Behavior of Gingival Fibroblasts on Titanium Implant Surfaces in Combination with either Injectable-PRF or PRP

    Directory of Open Access Journals (Sweden)

    Xuzhu Wang

    2017-02-01

    Full Text Available Various strategies have been employed to speed tissue regeneration using bioactive molecules. Interestingly, platelet concentrates derived from a patient’s own blood have been utilized as a regenerative strategy in recent years. In the present study, a novel liquid platelet formulation prepared without the use of anti-coagulants (injectable-platelet-rich fibrin, i-PRF was compared to standard platelet-rich plasma (PRP with gingival fibroblasts cultured on smooth and roughened titanium implant surfaces. Standard PRP and i-PRF (centrifuged at 700 rpm (60× g for 3 min were compared by assays for fibroblast biocompatibility, migration, adhesion, proliferation, as well as expression of platelet-derived growth factor (PDGF, transforming growth factor-β (TGF-β, collagen1 (COL1 and fibronectin (FN. The results demonstrate that i-PRF induced significantly higher cell migration, as well as higher messenger RNA (mRNA levels of PDGF, TGF-β, collagen1 and fibronectin when compared to PRP. Furthermore, collagen1 synthesis was highest in the i-PRF group. These findings demonstrate that liquid platelet concentrates can be formulated without the use of anticoagulants and present much translational potential for future research. Future animal and clinical trials are now necessary to further investigate the potential of utilizing i-PRF for soft tissue regenerative protocols in combination with various biomaterials.

  1. Mass spectrometric investigation of synthetic glycoside of muramyl dipeptide immobilized on fumed silica surface

    International Nuclear Information System (INIS)

    Kulik, Tetiana V.; Azizova, Liana R.; Palyanytsya, Borys B.; Zemlyakov, Alexander E.; Tsikalova, Victoria N.

    2010-01-01

    N-Acetylmuramyl-L-alanyl-D-isoglutamine or muramyl dipeptide is a cleavage product of peptidoglycan by lysozyme. This study explored the use of the temperature-programmed desorption mass spectrometry (TPDMS) in analysis of glycoside of muramyl dipeptide: O-{(4-tert-butylcyclohexyl)-2-acetamido-2, 3-dideoxy-β-D-glucopyranoside-3-yl}-D-lactoyl-L-alanyl-D-isoglutamine (MDP) on the surface of fumed silica. Stages of pyrolysis of MDP in condensed state and on the silica surface have been determined. Three stages have been clear identified under pyrolysis of MDP on the silica surface. Kinetic parameters of thermal reactions on the fumed silica surface and in the condensed state have been calculated.

  2. The Impact of Body Mass Index on Fluoroscopy Time During Lumbar Epidural Steroid Injection; A Multicenter Cohort Study.

    Science.gov (United States)

    McCormick, Zachary L; Choxi, Sarah C; Lee, David T; Marcolina, Austin; Press, Joel; Kennedy, D J; Smuck, Matthew; Walega, David R; Cushman, Daniel M

    2017-01-01

    This study aimed to assess the relationship between BMI and fluoroscopy time during lumbar epidural steroid injections (LESIs) performed for lumbosacral radicular pain. Multicenter retrospective cohort study. Three academic, outpatient pain treatment centers. Patients who underwent fluoroscopically guided LESI. Mean and standard deviation (SD) fluoroscopy time were compared between patients with normal (18.5-24.9 kg/m2), overweight (25.0-29.9 kg/m2), and obese (≥30.0 kg/m2) BMI. Statistical significance was set at P=0.01 due to multiple comparisons. A total of 2,930 procedure encounters were included, consisting of 598 interlaminar LESIs and 2,332 transforaminal LESIs. Fluoroscopy time was significantly longer in the obese patients compared to normal and overweight patients during interlaminar LESI (P Fluoroscopy time was significantly longer with each increasing BMI category in during transforaminal LESI (P fluoroscopy times were required in high BMI categories during L5-S1 transforaminal LESI (P fluoroscopy time and BMI during L4-L5 and S1 transforaminal LESI (P = 0.02; P = 0.13). Fluoroscopy time during interlaminar LESI compared to transforaminal LESI was significantly lower within all BMI categories (all Pfluoroscopy time is increased during interlaminar LESIs and during L5-S1 transforaminal LESIs in patients who are obese. These relationships are not affected by injection number, performance of bilateral injections, or trainee involvement. Further study is needed to determine if this increase in fluoroscopy time is indicative of a clinically significant associated increase in radiation dose. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. Application of a novel metabolomic approach based on atmospheric pressure photoionization mass spectrometry using flow injection analysis for the study of Alzheimer's disease.

    Science.gov (United States)

    González-Domínguez, Raúl; García-Barrera, Tamara; Gómez-Ariza, José Luis

    2015-01-01

    The use of atmospheric pressure photoionization is not widespread in metabolomics, despite its considerable potential for the simultaneous analysis of compounds with diverse polarities. This work considers the development of a novel analytical approach based on flow injection analysis and atmospheric pressure photoionization mass spectrometry for rapid metabolic screening of serum samples. Several experimental parameters were optimized, such as type of dopant, flow injection solvent, and their flows, given that a careful selection of these variables is mandatory for a comprehensive analysis of metabolites. Toluene and methanol were the most suitable dopant and flow injection solvent, respectively. Moreover, analysis in negative mode required higher solvent and dopant flows (100 µl min(-1) and 40 µl min(-1), respectively) compared to positive mode (50 µl min(-1) and 20 µl min(-1)). Then, the optimized approach was used to elucidate metabolic alterations associated with Alzheimer's disease. Thereby, results confirm the increase of diacylglycerols, ceramides, ceramide-1-phosphate and free fatty acids, indicating membrane destabilization processes, and reduction of fatty acid amides and several neurotransmitters related to impairments in neuronal transmission, among others. Therefore, it could be concluded that this metabolomic tool presents a great potential for analysis of biological samples, considering its high-throughput screening capability, fast analysis and comprehensive metabolite coverage. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Determination of low-molecular-weight dicarboxylic acids in atmospheric aerosols by injection-port derivatization and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Hsu, Ching-Lin; Ding, Wang-Hsien

    2009-12-15

    A rapid and environmental-friendly injection-port derivatization with gas chromatography-mass spectrometry (GC-MS) method was developed to determine selected low-molecular weight (LMW) dicarboxylic acids (from C2 to C10) in atmospheric aerosol samples. The parameters related to the derivatization process (i.e., type of ion-pair reagent, injection-port temperature and concentration of ion-pair reagent) were optimized. Tetrabutylammonium hydroxide (TBA-OH) 20 mM in methanol gave excellent yield for di-butyl ester dicarboxylate derivatives at injection-port temperature at 300 degrees C. Solid-phase extraction (SPE) method instead of rotary evaporation was used to concentrate analytes from filter extracts. The recovery from filter extracts ranged from 78 to 95% with relative standard deviation (RSD) less than 12%. Limits of quantitation (LOQs) ranged from 25 to 250 pg/m(3). The concentrations of di-carboxylated C2-C5 and total C6-C10 in particles of atmospheric aerosols ranged from 91.9 to 240, 11.3 to 56.7, 9.2 to 49.2, 8.7 to 35.3 and n.d. to 37.8 ng/m(3), respectively. Oxalic acid (C2) was the dominant LMW-dicarboxylic acids detected in aerosol samples. The quantitative results were comparable to the results obtained by the off-line derivatization.

  5. Mass spectrometric analysis of illicit drugs in wastewater and surface water.

    Science.gov (United States)

    Castiglioni, Sara; Zuccato, Ettore; Chiabrando, Chiara; Fanelli, Roberto; Bagnati, Renzo

    2008-01-01

    Residues of illicit drugs have been recently found in urban wastewater and surface water. Their levels reflect the amount of drugs collectively excreted by consumers and can therefore be used to estimate drug abuse. An overview of the most widely used illicit drugs and of the analytical methods used for their detection in wastewater and surface water is presented here. Solid-phase extraction and high performance liquid chromatography-tandem mass spectrometry are the techniques that have been used for these investigations. Instrumental conditions and fragmentation patterns of illicit drugs and their metabolites are described. (c) 2008 Wiley Periodicals, Inc.

  6. Re-discovering surface mass spectrometry: chemical mapping from micro to macro

    International Nuclear Information System (INIS)

    Lloyd, K.G.; O'Keefe, D.P.

    2004-01-01

    New developments in electronics, devices, micro-encapsulation, and other areas demand the ability to acquire molecularly-specific information from smaller and smaller features. ToF-SIMS provides molecularly-specific mass spectral data, but sufficient high-mass signal has historically been difficult to obtain from organic/polymeric surfaces in the point-mapping mode of operation. Use of chemometric data reduction methods and the development of heavier primary ion sources enhance and extend the chemical information in the mapping data. Large-area chemical mapping via sample stage rastering has also opened up new applications. This capability allows single-experiment mapping of large or multiple features, provides information on surface uniformity over end-use-relevant areas, and offers potential for combinatorial and other screening applications. Examples of these applications are presented

  7. Atmospheric pressure surface sampling/ionization techniques for direct coupling of planar separations with mass spectrometry.

    Science.gov (United States)

    Pasilis, Sofie P; Van Berkel, Gary J

    2010-06-18

    Planar separations, which include thin layer chromatography and gel electrophoresis, are in widespread use as important and powerful tools for conducting separations of complex mixtures. To increase the utility of planar separations, new methods are needed that allow in situ characterization of the individual components of the separated mixtures. A large number of atmospheric pressure surface sampling and ionization techniques for use with mass spectrometry have emerged in the past several years, and several have been investigated as a means for mass spectrometric read-out of planar separations. In this article, we review the atmospheric pressure surface sampling and ionization techniques that have been used for the read-out of planar separation media. For each technique, we briefly explain the operational basics and discuss the analyte type for which it is appropriate and some specific applications from the literature. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  8. Laser-based mass spectrometry for in situ chemical composition analysis of planetary surfaces

    Science.gov (United States)

    Frey, Samira; Neuland, Maike B.; Grimaudo, Valentine; Moreno-García, Pavel; Riedo, Andreas; Tulej, Marek; Broekmann, Peter; Wurz, Peter

    2016-04-01

    Mass spectrometry is an important analytical technique in space research. The chemical composition of planetary surface material is a key scientific question on every space mission to a planet, moon or asteroid. Chemical composition measurements of rocky material on the surface are of great importance to understand the origin and evolution of the planetary body.[1] A miniature laser ablation/ionisation reflectron- type time-of-flight mass spectrometer (instrument name LMS) was designed and built at the University of Bern for planetary research.[2] Despite its small size and light weight, the LMS instrument still maintains the same capabilities as large laboratory systems, which makes it suitable for its application on planetary space missions.[3-5] The high dynamic range of about eight orders of magnitude, high lateral (μm-level) and vertical (sub-nm level) resolution and high detection sensitivity for almost all elements (10 ppb, atomic fraction) make LMS a versatile instrument for various applications. LMS is a suitable instrument for in situ measurements of elemental and isotope composition with high precision and accuracy. Measurements of Pb- isotope abundances can be used for dating of planetary material. Measurements of bio-relevant elements allow searching for past or present life on a planetary surface. The high spatial resolution, both in lateral and vertical direction, is of considerable interest, e.g. for analysis of inhomogeneous, extraterrestrial samples as well as weathering processes of planetary material. References [1] P. Wurz, D. Abplanalp, M. Tulej, M. Iakovleva, V.A. Fernandes, A. Chumikov, and G. Managadze, "Mass Spectrometric Analysis in Planetary Science: Investigation of the Surface and the Atmosphere", Sol. Sys. Res., 2012, 46, 408. [2] U. Rohner, J.A. Whitby, P. Wurz, "A miniature laser ablation time of flight mass spectrometer for in situ planetary exploration" Meas. Sci. Tch., 2003, 14, 2159. [3] M. Tulej, A. Riedo, M.B. Neuland, S

  9. A Customizable Flow Injection System for Automated, High Throughput, and Time Sensitive Ion Mobility Spectrometry and Mass Spectrometry Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Orton, Daniel J. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Tfaily, Malak M. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Moore, Ronald J. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; LaMarche, Brian L. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Zheng, Xueyun [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Fillmore, Thomas L. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Chu, Rosalie K. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Weitz, Karl K. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Monroe, Matthew E. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Kelly, Ryan T. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Smith, Richard D. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States; Baker, Erin S. [Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA 99352, United States

    2017-12-13

    To better understand disease conditions and environmental perturbations, multi-omic studies (i.e. proteomic, lipidomic, metabolomic, etc. analyses) are vastly increasing in popularity. In a multi-omic study, a single sample is typically extracted in multiple ways and numerous analyses are performed using different instruments. Thus, one sample becomes many analyses, making high throughput and reproducible evaluations a necessity. One way to address the numerous samples and varying instrumental conditions is to utilize a flow injection analysis (FIA) system for rapid sample injection. While some FIA systems have been created to address these challenges, many have limitations such as high consumable costs, low pressure capabilities, limited pressure monitoring and fixed flow rates. To address these limitations, we created an automated, customizable FIA system capable of operating at diverse flow rates (~50 nL/min to 500 µL/min) to accommodate low- and high-flow instrument sources. This system can also operate at varying analytical throughputs from 24 to 1200 samples per day to enable different MS analysis approaches. Applications ranging from native protein analyses to molecular library construction were performed using the FIA system. The results from these studies showed a highly robust platform, providing consistent performance over many days without carryover as long as washing buffers specific to each molecular analysis were utilized.

  10. Stark effect of excitons in corrugated lateral surface superlattices: effect of centre-of-mass quantization

    International Nuclear Information System (INIS)

    Hong Sun

    1998-11-01

    The quantum confined Stark effect (QCSE) of excitons in GaAs/AlAs corrugated lateral surface superlattices (CLSSLs) is calculated. Blue and red shifts in the exciton energies are predicted for the heavy- and light-excitons in the CLSSLs, respectively, comparing with those in the unmodulated quantum well due to the different effective hole masses in the parallel direction. Sensitive dependence of the QCSE on the hole effective mass in the parallel direction is expected because of the ''centre-of-mass'' quantization (CMQ) induced by the periodic corrugated interfaces of the CLSSLs. The effect of the CMQ on the exciton mini-bands and the localization of the excitons in the CLSSLs is discussed. (author)

  11. Detection of alkylmethylphosphonic acids on leaf surfaces by static secondary ion mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ingram, J.C.; Groenewold, G.S.; Appelhans, A.D.; Delmore, J.E.; Dahl, D.A. (Idaho National Engineering Lab., Idaho Falls, ID (United States))

    1995-01-01

    Detection of environmental degradation products of nerve agents directly from the surface of plant leaves using static secondary ion mass spectrometry (SIMS) is demonstrated. Pinacolylmethylphosphonic acid (PMPA), isopropylmethylphosphonic acid (IMPA), and ethylmethylphosphonic acid (EMPA) were spiked from aqueous solutions onto philodendron leaves prior to analysis by static SIMS. Fragment ions were observed in the anion SIMS spectra from all three compounds at m/z 63, 77, 79, and 95, which are attributed to PO[sub 2][sup [minus

  12. Ambient mass spectrometry: From the planar to the non-planar surface analysis

    Czech Academy of Sciences Publication Activity Database

    Rejšek, Jan; Vrkoslav, Vladimír; Cvačka, Josef

    2017-01-01

    Roč. 15, č. 1 (2017), s. 31 ISSN 2336-7202. [Mezioborové setkání mladých biologů, biochemiků a chemiků /17./. 30.05.2017-01.06.2017, Milovy] Institutional support: RVO:61388963 Keywords : ambient mass spectrometry * thin layer chromatography * non-planar surface analysis Subject RIV: CB - Analytical Chemistry, Separation

  13. Protein surface topology-probing by selective chemical modification and mass spectrometric peptide mapping.

    OpenAIRE

    Suckau, D; Mak, M; Przybylski, M

    1992-01-01

    Aminoacetylation of lysine residues and the modification of arginine by 1,2-cyclohexanedione to N7,N8-(dihydroxy-1,2-cyclohexylidene)arginine were used for probing the surface topology of hen-eggwhite lysozyme as a model protein. The molecular identification of lysine and arginine modification sites was provided by molecular weight determinations of modified and unmodified tryptic peptide mixtures (peptide mapping) using 252Cf plasma desorption mass spectrometry. At conditions of limited chem...

  14. Mechanical Q-factor measurements on a test mass with a structured surface

    Energy Technology Data Exchange (ETDEWEB)

    Nawrodt, R [Institut fuer Festkoerperphysik, Friedrich-Schiller-Universitaet Jena, Helmholtzweg 5, D-07743 Jena (Germany); Zimmer, A [Institut fuer Festkoerperphysik, Friedrich-Schiller-Universitaet Jena, Helmholtzweg 5, D-07743 Jena (Germany); Koettig, T [Institut fuer Festkoerperphysik, Friedrich-Schiller-Universitaet Jena, Helmholtzweg 5, D-07743 Jena (Germany); Clausnitzer, T [Institut fuer Angewandte Physik, Friedrich-Schiller-Universitaet Jena, Max-Wien-Platz 1, D-07743 Jena (Germany); Bunkowski, A [Max-Planck-Institut fuer Gravitationsphysik (Albert-Einstein-Institut) and Institut fuer Gravitationsphysik, Leibniz Universitaet Hannover, Callinstr. 38, D-30167 Hannover (Germany); Kley, E B [Institut fuer Angewandte Physik, Friedrich-Schiller-Universitaet Jena, Max-Wien-Platz 1, D-07743 Jena (Germany); Schnabel, R [Max-Planck-Institut fuer Gravitationsphysik (Albert-Einstein-Institut) and Institut fuer Gravitationsphysik, Leibniz Universitaet Hannover, Callinstr. 38, D-30167 Hannover (Germany); Danzmann, K [Max-Planck-Institut fuer Gravitationsphysik (Albert-Einstein-Institut) and Institut fuer Gravitationsphysik, Leibniz Universitaet Hannover, Callinstr. 38, D-30167 Hannover (Germany); Nietzsche, S [Institut fuer Festkoerperphysik, Friedrich-Schiller-Universitaet Jena, Helmholtzweg 5, D-07743 Jena (Germany); Vodel, W [Institut fuer Festkoerperphysik, Friedrich-Schiller-Universitaet Jena, Helmholtzweg 5, D-07743 Jena (Germany); Tuennermann, A [Institut fuer Angewandte Physik, Friedrich-Schiller-Universitaet Jena, Max-Wien-Platz 1, D-07743 Jena (Germany); Seidel, P [Institut fuer Festkoerperphysik, Friedrich-Schiller-Universitaet Jena, Helmholtzweg 5, D-07743 Jena (Germany)

    2007-07-15

    We present mechanical Q-factors (quality factors) of a crystalline quartz test mass with a nano-structured surface, measured in the temperature regime from 5 to 300 K. The nano-structure was a grating with a period of 2 {mu}m and a depth of about 0.1 {mu}m. Comparative measurements were performed on the plain substrate and on the structured test mass with different numbers of SiO{sub 2}/Ta{sub 2}O{sub 5} coating layers. The measurements at different stages of the test mass fabrication process show that the surface distortion induced by the nanostructure does not severely lower the mechanical Q-factor of the substrate. Damping due to a multi-layer coating stack was found to be orders of magnitude higher. The results provide vital information concerning the potential usage of low-thermal noise nano-structured test masses in future generations of high-precision laser interferometers and in current attempts to measure quantum effects of macroscopic mirror oscillators.

  15. Investigation into Mass Loading Sensitivity of Sezawa Wave Mode-Based Surface Acoustic Wave Sensors

    Directory of Open Access Journals (Sweden)

    N. Ramakrishnan

    2013-02-01

    Full Text Available In this work mass loading sensitivity of a Sezawa wave mode based surface acoustic wave (SAW device is investigated through finite element method (FEM simulation and the prospects of these devices to function as highly sensitive SAW sensors is reported. A ZnO/Si layered SAW resonator is considered for the simulation study. Initially the occurrence of Sezawa wave mode and displacement amplitude of the Rayleigh and Sezawa wave mode is studied for lower ZnO film thickness. Further, a thin film made of an arbitrary material is coated over the ZnO surface and the resonance frequency shift caused by mass loading of the film is estimated. It was observed that Sezawa wave mode shows significant sensitivity to change in mass loading and has higher sensitivity (eight times higher than Rayleigh wave mode for the same device configuration. Further, the mass loading sensitivity was observed to be greater for a low ZnO film thickness to wavelength ratio. Accordingly, highly sensitive SAW sensors can be developed by coating a sensing medium over a layered SAW device and operating at Sezawa mode resonance frequency. The sensitivity can be increased by tuning the ZnO film thickness to wavelength ratio.

  16. Secondary ion mass spectrometric signal enhancement of phosphatidylcholine dioleoyl on enlarged nanoparticles surface

    Energy Technology Data Exchange (ETDEWEB)

    Gulin, A. [N.N. Semenov Institute of Chemical Physics, RAS, Kosigin str. 4, Moscow 119991 (Russian Federation); Mochalova, M. [Moscow Institute of Physics and Technology, Institutskii per. 9, Dolgoprudny, Moscow 141700 (Russian Federation); Denisov, N. [Institute of Problem of Chemical Physics, RAS, Semenov av. 1, Chernogolovka, 142432 (Russian Federation); Nadtochenko, V., E-mail: nadtochenko@gmail.com [N.N. Semenov Institute of Chemical Physics, RAS, Kosigin str. 4, Moscow 119991 (Russian Federation); Moscow Institute of Physics and Technology, Institutskii per. 9, Dolgoprudny, Moscow 141700 (Russian Federation); Institute of Problem of Chemical Physics, RAS, Semenov av. 1, Chernogolovka, 142432 (Russian Federation)

    2014-10-15

    Graphical abstract: - Highlights: • TOF-SIMS mass-spectra of DOPC lipid on enlarged nanoparticles surface were studied. • Metallic, semiconductor, dielectric and hybrid nanoparticles were examined. • Effect of nanoparticles on mass-spectral peaks intensity was investigated. • The highest signal enhancement of 42 times was found for hybrid core–shell Au/SiO{sub 2} nanoparticles. - Abstract: A silicon wafer surface coverage of nanoparticles (NPs) can enhance the L-α-phosphatidylcholine dioleoyl (DOPC) signal intensity in time-of-flight secondary ion mass spectrometry (TOF-SIMS). A ToF-SIMS mass spectrometer was used with a pulsed primary beam of focused 30 keV Bi{sub 3}{sup +} ions. The signal enhancing effect has been studied for metallic (Ag, Au, Pb), semiconductor (TiO{sub 2}), dielectric (SiO{sub 2}) and hybrid (Au/TiO{sub 2}NPs, core–shell Au/SiO{sub 2}) nanoparticles. Ag NPs can attenuate secondary ions signal, whereas all other studied NPs show the signal enhancement. The emission of DOPC lipid secondary ions immobilized on core–shell Au/SiO{sub 2}NPs was enhanced up to 42 times. This technique is a simple preparatory method enabling an overall increase in molecular lipid ions.

  17. Secondary ion mass spectrometric signal enhancement of phosphatidylcholine dioleoyl on enlarged nanoparticles surface

    International Nuclear Information System (INIS)

    Gulin, A.; Mochalova, M.; Denisov, N.; Nadtochenko, V.

    2014-01-01

    Graphical abstract: - Highlights: • TOF-SIMS mass-spectra of DOPC lipid on enlarged nanoparticles surface were studied. • Metallic, semiconductor, dielectric and hybrid nanoparticles were examined. • Effect of nanoparticles on mass-spectral peaks intensity was investigated. • The highest signal enhancement of 42 times was found for hybrid core–shell Au/SiO 2 nanoparticles. - Abstract: A silicon wafer surface coverage of nanoparticles (NPs) can enhance the L-α-phosphatidylcholine dioleoyl (DOPC) signal intensity in time-of-flight secondary ion mass spectrometry (TOF-SIMS). A ToF-SIMS mass spectrometer was used with a pulsed primary beam of focused 30 keV Bi 3 + ions. The signal enhancing effect has been studied for metallic (Ag, Au, Pb), semiconductor (TiO 2 ), dielectric (SiO 2 ) and hybrid (Au/TiO 2 NPs, core–shell Au/SiO 2 ) nanoparticles. Ag NPs can attenuate secondary ions signal, whereas all other studied NPs show the signal enhancement. The emission of DOPC lipid secondary ions immobilized on core–shell Au/SiO 2 NPs was enhanced up to 42 times. This technique is a simple preparatory method enabling an overall increase in molecular lipid ions

  18. Effects of acetic acid injection and operating conditions on NO emission in a vortexing fluidized bed combustor using response surface methodology

    Energy Technology Data Exchange (ETDEWEB)

    Fuping Qian; Chiensong Chyang; Weishen Yen [Anhui University of Technology, Ma' anshan (China). School of Civil Engineering and Architecture

    2009-07-15

    The effects of acetic acid injection and operating conditions on NO emission were investigated in a pilot scale vortexing fluidized bed combustor (VFBC), an integration of circular freeboard and a rectangular combustion chamber. Operating conditions, such as the stoichiometric oxygen in the combustion chamber, the bed temperature and the injecting location of acetic acid, were determined by means of response surface methodology (RSM), which enables the examination of parameters with a moderate number of experiments. In RSM, NO emission concentration after acetic acid injection and NO removal percentage at the exit of the VFBC are used as the objective function. The results show that the bed temperature has a more important effect on the NO emission than the injecting location of acetic acid and the stoichiometric oxygen in the combustion chamber. Meanwhile, the injecting location of acetic acid and the stoichiometric oxygen in the combustion chamber have a more important effect on the NO removal percentage than the bed temperature. NO emission can be decreased by injecting the acetic acid into the combustion chamber, and NO emission decreases with the height of the acetic acid injecting location above the distributor. On the other hand, NO removal percentage increases with the height of the acetic acid injecting location, and NO emission increases with the stoichiometric oxygen in the combustion chamber and the bed temperature. NO removal percentage increases with the stoichiometric oxygen, and increases first, then decreases with the bed temperature. Also, a higher NO removal percentage could be obtained at 850{sup o}C. 26 refs., 12 figs., 8 tabs.

  19. Reconciling satellite aerosol optical thickness and surface fine particle mass through aerosol liquid water: ALW AND AOT

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Thien Khoi V. [Department of Environmental Sciences, Rutgers University, New Brunswick New Jersey USA; Ghate, Virendra P. [Environmental Science Division, Argonne National Laboratory, Argonne Illinois USA; Carlton, Annmarie G. [Department of Chemistry, University of California, Irvine California USA

    2016-11-22

    Summertime aerosol optical thickness (AOT) over the Southeast U.S. is sharply enhanced over wintertime values. This seasonal pattern is unique and of particular interest because temperatures there have not warmed over the past 100 years. Patterns in surface fine particle mass are inconsistent with satellite reported AOT. In this work, we attempt to reconcile the spatial and temporal distribution of AOT over the U.S. with particle mass measurements at the surface by examining trends in aerosol liquid water (ALW), a particle constituent that scatters radiation affecting the satellite AOT, but is removed in mass measurements at routine surface monitoring sites. We employ the thermodynamic model ISORROPIAv2.1 to estimate ALW mass concentrations at IMRPOVE sites using measured ion mass concentrations and NARR meteorological data. Our findings suggest ALW provides a plausible explanation for the geographical and seasonal patterns in AOT and can reconcile previously noted discrepancies with surface mass measurements.

  20. Study of the interaction of liquid with the surface of mass standards of high accuracy stainless steel

    International Nuclear Information System (INIS)

    Ramirez Varas, Lautaro; Castro, Claudio S.C.; Cacais, Fabio L.; Pires, Manoel J. M.; Loayza Mendoza, Victor M.

    2011-01-01

    The long term stability of mass standards depends on the interaction between the surface and environment molecules. From this point of view, a study was investigated of the effect on stainless steel surfaces by liquids frequently used in hydrostatic weighing (FC40) and in cleaning procedures of mass standards (isopropyl alcohol). Firstly, mass weighing difference was measured as function of time with a gravimetric method. Additionally, stainless steel samples were analyzed by X-ray Photoelectron Spectroscopy (XPS). The standard used for the gravimetric mass difference determination was immersed in FC40. The samples analyzed by XPS were previously immersed in both FC40 and isopropyl alcohol. Mass differences were obtained with an uncertainty of 1 μg when FC40 was used. Preliminary results have suggested that FC40 is not chemically bound to stainless steel surfaces and the mass gain was due to physisorbed molecules on the surface. (author) [es

  1. Monitoring of lactic fermentation driven by different starter cultures via direct injection mass spectrometric analysis of flavour-related volatile compounds.

    Science.gov (United States)

    Benozzi, Elisabetta; Romano, Andrea; Capozzi, Vittorio; Makhoul, Salim; Cappellin, Luca; Khomenko, Iuliia; Aprea, Eugenio; Scampicchio, Matteo; Spano, Giuseppe; Märk, Tilmann D; Gasperi, Flavia; Biasioli, Franco

    2015-10-01

    In this work, we used Proton Transfer Reaction-Mass Spectrometry (PTR-ToF-MS), coupled with an automated sampling system, to monitor lactic fermentation driven by different yogurt commercial starter cultures via direct injection mass spectrometric analysis of flavour-related volatile compounds. The aim is the identification of markers for real-time and non-invasive bioprocess control and optimisation as an industrial driver of innovation in food technology and biotechnology. We detected more than 300 mass peaks, tentatively identifying all major yogurt aroma volatiles. Thirteen mass peaks showed statistically significant differences among the four commercial starters. Among these are acetaldehyde, methanethiol, butanoic acid, 2-butanone, diacetyl, acetoin, 2-hydroxy-3-pentanone/pentanoic acid, heptanoic acid and benzaldehyde which play a key role in yogurt flavour. These volatile described the diverse flavour properties claimed by food biotechnological companies and, considering the possible contribution to yogurt flavour, are potential markers for the rapid screening of starter cultures and for the quality design in this fermentation-driven production. The strength of our approach lies in the identification, for the first time, of specific depletion kinetics of four sulphur containing compounds occurring during fermentation (hydrogen sulphide, methanethiol, S-methyl thioacetate/S-ethyl thioformate, pentane-thiol), which suggest a new possible protechnological feature of yogurt starter cultures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Direct injection liquid chromatography/electrospray ionization mass spectrometric horse urine analysis for the quantification and confirmation of threshold substances for doping control. II. Determination of theobromine.

    Science.gov (United States)

    Vonaparti, A; Lyris, E; Panderi, I; Koupparis, M; Georgakopoulos, C

    2009-04-01

    In equine sport, theobromine is prohibited with a threshold level of 2 microg mL(-1) in urine, hence doping control laboratories have to establish quantitative and qualitative methods for its determination. Two simple liquid chromatography/mass spectrometry (LC/MS) methods for the identification and quantification of theobromine were developed and validated using the same sample preparation procedure but different mass spectrometric systems: ion trap mass spectrometry (ITMS) and time-of-flight mass spectrometry (TOFMS). Particle-free diluted urine samples were directly injected into the LC/MS systems, avoiding the time-consuming extraction step. 3-Propylxanthine was used as the internal standard. The tested linear range was 0.75-15 microg mL(-1). Matrix effects were evaluated analyzing calibration curves in water and different fortified horse urine samples. A great variation in the signal of theobromine and the internal standard was observed in different matrices. To overcome matrix effects, a standard additions calibration method was applied. The relative standard deviations of intra- and inter-day analysis were lower than 8.6 and 7.2%, respectively, for the LC/ITMS method and lower than 5.7 and 5.8%, respectively, for the LC/TOFMS method. The bias was less than 8.7% for both methods. The methods were applied to two case samples, demonstrating simplicity, accuracy and selectivity. Copyright (c) 2009 John Wiley & Sons, Ltd.

  3. Mass transfer of CO2 to groundwaters from a near-surface waste disposal site

    International Nuclear Information System (INIS)

    Caron, F.; Wilkinson, S.R.; Manni, G.; Torok, J.

    1995-01-01

    Gaseous 14 CO 2 originating from buried low-level radioactive wastes (LLRW) in a near-surface disposal site can be released to the environment via two major paths: gas-phase diffusion through soils to the atmosphere, and dissolution in groundwater, followed by aqueous migration. Aqueous migration would give the highest dose to an individual, especially if C-14 was converted to an organic form and ingested. Gaseous diffusion would give a lower dose, largely because of atmospheric dispersion and dilution. The objective of this study was to develop the capability to estimate which of the two paths will likely be dominant for typical near-surface disposal facilities. The main missing parameter for making this estimate was a mass-transfer coefficient (K L ) of 14 CO 2 to groundwaters, which was determined experimentally using a large sand box. The K L thus determined was approximately 10 to 20 times smaller than for an open liquid surface. This suggests that there is a potential resistance to mass transfer, probably caused by the capillary fringe. The value obtained was incorporated into a simple model of CO 2 transport around a typical near-surface disposal site. The model suggests that CO 2 transport via both gaseous release and aqueous migration paths are of similar magnitude for a repository located ∼2 m above the water table. (author). 11 refs., 2 tabs., 2 figs

  4. Chemical characterization of neonicotinoids in surface waters by high performance liquid chromatography with Tandem Mass Spectrometry (HPLC MS/MS)

    International Nuclear Information System (INIS)

    Amaral, Priscila Oliveira

    2017-01-01

    The present study aimed to develop a method for the determination and validation of a method for the identification and quantification of Neonicotinoids in surface waters collected in the Bauru region, in the state of São Paulo. The analytical techniques studied for the development of this method were the high performance liquid chromatography with tandem mass spectrometry (HPLC - MS / MS), gas chromatography with mass spectrometry (GC / MS) and gas chromatography with electron capture detector (GC / ECD). The class of pesticides Neonicotinoids was chosen for this work because it is related to a sudden disappearance of bees in colonies around the world. This phenomenon is known as Colony Collapse Disorder (CCD) and it is characterized by a rapid loss in the population of adult bees. The Neonicotinoids used in this study were the compounds Clothianidin, Imidacloprid and Thiamethoxam which were banned in their use as pesticides in Europe by Implementing Regulation No. 540/2011. The samples were concentrated using solid phase extraction (SPE) and liquid liquid extraction (LLE) techniques and injected into HPLC-MS / MS, GC / MS and GC / ECD. The GC / ECD and GC / MS techniques were not satisfactory for determination in the water matrix because the detection limit (10 mg L -1 ) is above the maximum allowed by the US Environmental Protection Agency (0.6 μg L -1 ). The HPLC - MS / MS technique using the multiple reaction monitoring (MRM) proved to be adequate for this study because it obtained quantification limits between 5.89 and 8.06 μg L -1 and a linearity between 0.9963 and 0.9999 for the three compounds. (author)

  5. Mass balance and surface movement of the Greenland Ice Sheet at Summit, Central Greenland

    DEFF Research Database (Denmark)

    Hvidberg, C.S.; Keller, K.; Gundestrup, N.S.

    1997-01-01

    During the GRIP deep drilling in Central Greenland, the ice sheet topography and surface movement at Summit has been mapped with GPS. Measurements of the surface velocity are presented for a strain net consisting of 13 poles at distances of 25-60 km from the GRIP site. Some results are: The GRIP...... site is located approximately 2 km NW of the topographic summit; the surface velocity at the GISP 2 site is 1.7 m/yr in the W direction. The present mass balance at Summit is calculated to be -0.03+/-0.04 m/yr, i.e. close to steady state. This result is the best now available for Summit. A small...... thinning rate might be a transient response of the Greenland Ice Sheet due to the temperature increase at the Wisconsin-Holocene transition....

  6. Surface-enhanced Raman detection of RNA and DNA bases following flow-injection analysis or HPLC separation

    Science.gov (United States)

    Cotton, Therese M.; Sheng, Rong-Sheng; Ni, Fan

    1990-11-01

    The goal of this study is to develop Surface-enhanced Raman scattering (SERS) detection methods for flow injection analysis (FIA) and high performance liquid chromatography (HPLC). Nucleic acid bases have been chosen for analysis because of their importance in life processes. The advantages to the use of SERS-based detection include its sensitivity, specificity and versatility. With the development of improved methodology, the detection limits should be comparable to UV spectroscopy. However, the specificity is considerably superior to that obtained with electronic spectroscopy in that the Raman spectrum provides a molecular fingerprint of the individual analytes. Raman spectroscopy is very versatile: aqueous samples, gases and solids can be analyzed with equal facility. The results presented here demonstrate that SERS can be used as a detection method for both FIA and HPLC detection. In the following experiments Ag sols have been used as the active substrate. The effect of various parameters such as temperature, pH, flow rate, and the nature of the interface between the HPLC system and the Raman spectrometer have been examined. One of the most significant findings is that the temperature of the Ag sol/HPLC effluent mixture has a dramatic effect on the SERS intensities. This effect is a result of increased colloid aggregation at higher temperatures. Aggregation is known to produce greater enhancement in SERS and proceeds much more rapidly at elevated temperatures. An increase in the temperature of the Ag sol enables SERS detection under flowing conditions and in real time. This is a substantial improvement over many of the previous attempts to interface SERS detection to FIA or HPLC. In most of the previous studies, it was necessary to stop the flow as the analyte eluted from the chromatogram and measure the SERS spectra under static conditions.

  7. The galactic disk surface mass density and the Galactic force K(z) at z = 1.1 kiloparsecs

    International Nuclear Information System (INIS)

    Kuijken, K.; Gilmore, G.

    1991-01-01

    A set of distance and velocity data previously obtained and analyzed is rediscussed to determine the surface mass density of the Galactic disk. These data reliably determine the integral surface mass density of all (disk + halo) Galactic components within 1.1 kpc from the Galactic plane near the sun to be 71 + or 6 solar masses/sq pc, independent of the disk/halo ratio. Determination of the fraction of this total mass which is distributed in the Galactic disk and the fraction which is associated with an extended halo remains highly model-dependent. The best available estimate of the relative contributions of disk mass and halo mass to the local integral surface density, obtained from modeling of the Galactic rotation curve, yields a surface mass density of 48 + or - 9 solar masses/sq pc for mass associated with the Galactic disk near the sun. The corresponding mass of identified disk matter is 48 + or - 8 solar masses/sq pc. 7 refs

  8. Surface Mass Balance of the Greenland Ice Sheet Derived from Paleoclimate Reanalysis

    Science.gov (United States)

    Badgeley, J.; Steig, E. J.; Hakim, G. J.; Anderson, J.; Tardif, R.

    2017-12-01

    Modeling past ice-sheet behavior requires independent knowledge of past surface mass balance. Though models provide useful insight into ice-sheet response to climate forcing, if past climate is unknown, then ascertaining the rate and extent of past ice-sheet change is limited to geological and geophysical constraints. We use a novel data-assimilation framework developed under the Last Millennium Reanalysis Project (Hakim et al., 2016) to reconstruct past climate over ice sheets with the intent of creating an independent surface mass balance record for paleo ice-sheet modeling. Paleoclimate data assimilation combines the physics of climate models and the time series evidence of proxy records in an offline, ensemble-based approach. This framework allows for the assimilation of numerous proxy records and archive types while maintaining spatial consistency with known climate dynamics and physics captured by the models. In our reconstruction, we use the Community Climate System Model version 4, CMIP5 last millennium simulation (Taylor et al., 2012; Landrum et al., 2013) and a nearly complete database of ice core oxygen isotope records to reconstruct Holocene surface temperature and precipitation over the Greenland Ice Sheet on a decadal timescale. By applying a seasonality to this reconstruction (from the TraCE-21ka simulation; Liu et al., 2009), our reanalysis can be used in seasonally-based surface mass balance models. Here we discuss the methods behind our reanalysis and the performance of our reconstruction through prediction of unassimilated proxy records and comparison to paleoclimate reconstructions and reanalysis products.

  9. Surface Energy and Mass Balance Model for Greenland Ice Sheet and Future Projections

    Science.gov (United States)

    Liu, Xiaojian

    The Greenland Ice Sheet contains nearly 3 million cubic kilometers of glacial ice. If the entire ice sheet completely melted, sea level would raise by nearly 7 meters. There is thus considerable interest in monitoring the mass balance of the Greenland Ice Sheet. Each year, the ice sheet gains ice from snowfall and loses ice through iceberg calving and surface melting. In this thesis, we develop, validate and apply a physics based numerical model to estimate current and future surface mass balance of the Greenland Ice Sheet. The numerical model consists of a coupled surface energy balance and englacial model that is simple enough that it can be used for long time scale model runs, but unlike previous empirical parameterizations, has a physical basis. The surface energy balance model predicts ice sheet surface temperature and melt production. The englacial model predicts the evolution of temperature and meltwater within the ice sheet. These two models can be combined with estimates of precipitation (snowfall) to estimate the mass balance over the Greenland Ice Sheet. We first compare model performance with in-situ observations to demonstrate that the model works well. We next evaluate how predictions are degraded when we statistically downscale global climate data. We find that a simple, nearest neighbor interpolation scheme with a lapse rate correction is able to adequately reproduce melt patterns on the Greenland Ice Sheet. These results are comparable to those obtained using empirical Positive Degree Day (PDD) methods. Having validated the model, we next drove the ice sheet model using the suite of atmospheric model runs available through the CMIP5 atmospheric model inter-comparison, which in turn built upon the RCP 8.5 (business as usual) scenarios. From this exercise we predict how much surface melt production will increase in the coming century. This results in 4-10 cm sea level equivalent, depending on the CMIP5 models. Finally, we try to bound melt water

  10. Estimation of surface area concentration of workplace incidental nanoparticles based on number and mass concentrations

    Science.gov (United States)

    Park, J. Y.; Ramachandran, G.; Raynor, P. C.; Kim, S. W.

    2011-10-01

    Surface area was estimated by three different methods using number and/or mass concentrations obtained from either two or three instruments that are commonly used in the field. The estimated surface area concentrations were compared with reference surface area concentrations (SAREF) calculated from the particle size distributions obtained from a scanning mobility particle sizer and an optical particle counter (OPC). The first estimation method (SAPSD) used particle size distribution measured by a condensation particle counter (CPC) and an OPC. The second method (SAINV1) used an inversion routine based on PM1.0, PM2.5, and number concentrations to reconstruct assumed lognormal size distributions by minimizing the difference between measurements and calculated values. The third method (SAINV2) utilized a simpler inversion method that used PM1.0 and number concentrations to construct a lognormal size distribution with an assumed value of geometric standard deviation. All estimated surface area concentrations were calculated from the reconstructed size distributions. These methods were evaluated using particle measurements obtained in a restaurant, an aluminum die-casting factory, and a diesel engine laboratory. SAPSD was 0.7-1.8 times higher and SAINV1 and SAINV2 were 2.2-8 times higher than SAREF in the restaurant and diesel engine laboratory. In the die casting facility, all estimated surface area concentrations were lower than SAREF. However, the estimated surface area concentration using all three methods had qualitatively similar exposure trends and rankings to those using SAREF within a workplace. This study suggests that surface area concentration estimation based on particle size distribution (SAPSD) is a more accurate and convenient method to estimate surface area concentrations than estimation methods using inversion routines and may be feasible to use for classifying exposure groups and identifying exposure trends.

  11. Estimation of surface area concentration of workplace incidental nanoparticles based on number and mass concentrations

    International Nuclear Information System (INIS)

    Park, J. Y.; Ramachandran, G.; Raynor, P. C.; Kim, S. W.

    2011-01-01

    Surface area was estimated by three different methods using number and/or mass concentrations obtained from either two or three instruments that are commonly used in the field. The estimated surface area concentrations were compared with reference surface area concentrations (SA REF ) calculated from the particle size distributions obtained from a scanning mobility particle sizer and an optical particle counter (OPC). The first estimation method (SA PSD ) used particle size distribution measured by a condensation particle counter (CPC) and an OPC. The second method (SA INV1 ) used an inversion routine based on PM1.0, PM2.5, and number concentrations to reconstruct assumed lognormal size distributions by minimizing the difference between measurements and calculated values. The third method (SA INV2 ) utilized a simpler inversion method that used PM1.0 and number concentrations to construct a lognormal size distribution with an assumed value of geometric standard deviation. All estimated surface area concentrations were calculated from the reconstructed size distributions. These methods were evaluated using particle measurements obtained in a restaurant, an aluminum die-casting factory, and a diesel engine laboratory. SA PSD was 0.7–1.8 times higher and SA INV1 and SA INV2 were 2.2–8 times higher than SA REF in the restaurant and diesel engine laboratory. In the die casting facility, all estimated surface area concentrations were lower than SA REF . However, the estimated surface area concentration using all three methods had qualitatively similar exposure trends and rankings to those using SA REF within a workplace. This study suggests that surface area concentration estimation based on particle size distribution (SA PSD ) is a more accurate and convenient method to estimate surface area concentrations than estimation methods using inversion routines and may be feasible to use for classifying exposure groups and identifying exposure trends.

  12. Gold-enhanced biomolecular surface imaging of cells and tissue by SIMS and MALDI mass spectrometry.

    Science.gov (United States)

    Altelaar, A F Maarten; Klinkert, Ivo; Jalink, Kees; de Lange, Robert P J; Adan, Roger A H; Heeren, Ron M A; Piersma, Sander R

    2006-02-01

    Surface metallization by plasma coating enhances desorption/ionization of membrane components such as lipids and sterols in imaging time-of-flight secondary ion mass spectrometry (TOF-SIMS) of tissues and cells. High-resolution images of cholesterol and other membrane components were obtained for neuroblastoma cells and revealed subcellular details (resolving power 1.5 mum). Alternatively, in matrix-enhanced SIMS, 2,5-dihydroxybenzoic acid electrosprayed on neuroblastoma cells allowed intact molecular ion imaging of phosphatidylcholine and sphingomyelin at the cellular level. Gold deposition on top of matrix-coated rat brain tissue sections strongly enhanced image quality and signal intensity in stigmatic matrix-assisted laser desorption/ionization imaging mass spectrometry. High-quality total ion count images were acquired, and the neuropeptide vasopressin was localized in the rat brain tissue section at the hypothalamic area around the third ventricle. Although the mechanism of signal enhancement by gold deposition is under debate, the results we have obtained for cells and tissue sections illustrate the potential of this sample preparation technique for biomolecular surface imaging by mass spectrometry.

  13. Controlled-Resonant Surface Tapping-Mode Scanning Probe Electrospray Ionization Mass Spectrometry Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lorenz, Matthias [ORNL; Ovchinnikova, Olga S [ORNL; Kertesz, Vilmos [ORNL; Van Berkel, Gary J [ORNL

    2014-01-01

    This paper reports on the advancement of a controlled-resonance surface tapping-mode single capillary liquid junction extraction/ESI emitter for mass spectrometry imaging. The basic instrumental setup and the general operation of the system were discussed and optimized performance metrics were presented. The ability to spot sample, lane scan and chemically image in an automated and controlled fashion were demonstrated. Rapid, automated spot sampling was demonstrated for a variety of compound types including the cationic dye basic blue 7, the oligosaccharide cellopentaose, and the protein equine heart cytochrome c. The system was used for lane scanning and chemical imaging of the cationic dye crystal violet in inked lines on glass and for lipid distributions in mouse brain thin tissue sections. Imaging of the lipids in mouse brain tissue under optimized conditions provided a spatial resolution of approximately 35 m based on the ability to distinguish between features observed both in the optical and mass spectral chemical images. The sampling spatial resolution of this system was comparable to the best resolution that has been reported for other types of atmospheric pressure liquid extraction-based surface sampling/ionization techniques used for mass spectrometry imaging.

  14. Identification of xenobiotic metabolites from biological fluids using flow injection analysis high-resolution mass spectrometry and post-acquisition data filtering.

    Science.gov (United States)

    Rathahao-Paris, Estelle; Paris, Alain; Bursztyka, Julian; Jaeg, Jean-Philippe; Cravedi, Jean-Pierre; Debrauwer, Laurent

    2014-12-30

    Concern for public health entails the need to evaluate the degree of exposure of population to toxicants. To do this, robust high-throughput approaches are required to be able to perform a large number of analyses in cohort studies. In this study, a data-filtering procedure was applied to mass spectral data acquired by direct analysis of biological fluids leading to rapid detection of metabolites in a model xenobiotic system. Flow injection analysis (FIA) coupled to negative electrospray ionization (ESI)-LTQ Orbitrap Fourier transform mass spectrometry was used to directly analyze urine of rats treated with vinclozolin. Tandem mass spectrometry (MS/MS) experiments were subsequently performed for confirmation of a new metabolite structure. The isotope filtering based on the difference between accurate masses of (35)Cl and (37)Cl was applied to the raw data for the specific detection of ions containing at least one chlorine atom. Seven metabolites of vinclozolin were manually identified thanks to the characteristic isotope pattern of dichlorinated compounds. A new metabolite of vinclozolin was detected for the first time and identified as a sulfate conjugate. The application of an isotope-filtering procedure allowed the selective extraction of pertinent signals from the data. The processed mass spectrum was greatly simplified, significantly facilitating the detection of the seven metabolites previously identified. The use of FIA-HRMS in combination with dedicated bio-informatics data processing is shown to be an efficient approach for the rapid detection of metabolites in biological fluids. This is a very promising high-throughput approach for rapid characterization of the exposure status to xenobiotics. Copyright © 2014 John Wiley & Sons, Ltd.

  15. Constructing a mass measurement error surface to improve automatic annotations in liquid chromatography/mass spectrometry based metabolomics

    NARCIS (Netherlands)

    Shahaf, N.; Franceschi, P.; Arapitsas, P.; Rogachev, I.; Vrhovsek, U.; Wehrens, H.R.M.J.

    2013-01-01

    RATIONALE Estimation of mass measurement accuracy is an elementary step in the application of mass spectroscopy (MS) data towards metabolite annotations and has been addressed several times in the past. However, the reproducibility of mass measurements over a diverse set of analytes and in variable

  16. Climate dependent contrast in surface mass balance in East Antarctica over the past 216 ka

    Science.gov (United States)

    Parrenin, Frédéric; Fujita, Shuji; Abe-Ouchi, Ayako; Kawamura, Kenji; Masson-Delmotte, Valérie; Motoyama, Hideaki; Saito, Fuyuki; Severi, Mirko; Stenni, Barbara; Uemura, Ryu; Wolff, Eric

    2017-04-01

    Documenting past changes in the East Antarctic surface mass balance is important to improve ice core chronologies and to constrain the ice-sheet contribution to global mean sea-level change. Here we reconstruct past changes in the ratio of surface mass balance (SMB ratio) between the EPICA Dome C (EDC) and Dome Fuji (DF) East Antarctica ice core sites, based on a precise volcanic synchronization of the two ice cores and on corrections for the vertical thinning of layers. During the past 216 000 a, this SMB ratio, denoted SMB EDC /SMB DF , varied between 0.7 and 1.1, being small during cold periods and large during warm periods. Our results therefore reveal larger amplitudes of changes in SMB at EDC compared with DF, consistent with previous results showing larger amplitudes of changes in water stable isotopes and estimated surface temperature at EDC compared with DF. Within the last glacial inception (Marine Isotope Stages, MIS-5c and MIS-5d), the SMB ratio deviates by up to 0.2 from what is expected based on differences in water stable isotope records. Moreover, the SMB ratio is constant throughout the late parts of the current and last interglacial periods, despite contrasting isotopic trends.

  17. Impact-induced concerted mass transport on W surfaces by a voidion mechanism

    Science.gov (United States)

    Mazilova, T. I.; Sadanov, E. V.; Voyevodin, V. N.; Ksenofontov, V. A.; Mikhailovskij, I. M.

    2018-03-01

    Using low-temperature field ion microscope techniques, we studied at the atomic level morphological evolution of the W surface through bombardment by a beam of several keV He atoms. This technique allows the direct observation of the results of the high energy He atom impact on the elementary damage stages. The formation of the 〈110〉 and 〈100〉 linear vacancy chains and the high relaxation of the near-neighbors of the surface vacancy clusters were revealed. Performed molecular dynamics simulations shows that a single He atom impact triggers the relaxation process of the linear vacancy chain by a substantial decrease of the distance between atoms at both sides of the chain. The observed inward relaxations in W and Mo are an order of magnitude more than that for a single vacancy. It was revealed a novel highly cooperative impact-induced mass transport mechanism on the stepped surface: the formation and motion of a surface spatially delocalized vacancies (voidions). Surface voidions are extremely mobile: the mean velocity of atoms in voidions equals to a substantial portion of the sound velocity. Successive collective translations of the 〈111〉 lines of atoms in adjacent voidions give rise to a concerted gliding motion of great atomic clusters.

  18. Mass Sensitivity Optimization of a Surface Acoustic Wave Sensor Incorporating a Resonator Configuration

    Directory of Open Access Journals (Sweden)

    Wenchang Hao

    2016-04-01

    Full Text Available The effect of the sensitive area of the two-port resonator configuration on the mass sensitivity of a Rayleigh surface acoustic wave (R-SAW sensor was investigated theoretically, and verified in experiments. A theoretical model utilizing a 3-dimensional finite element method (FEM approach was established to extract the coupling-of-modes (COM parameters in the absence and presence of mass loading covering the electrode structures. The COM model was used to simulate the frequency response of an R-SAW resonator by a P-matrix cascading technique. Cascading the P-matrixes of unloaded areas with mass loaded areas, the sensitivity for different sensitive areas was obtained by analyzing the frequency shift. The performance of the sensitivity analysis was confirmed by the measured responses from the silicon dioxide (SiO2 deposited on different sensitive areas of R-SAW resonators. It is shown that the mass sensitivity varies strongly for different sensitive areas, and the optimal sensitive area lies towards the center of the device.

  19. The role of mass balance equations in growth mechanics illustrated in surface and volume dissolutions.

    Science.gov (United States)

    Ateshian, Gerard A

    2011-01-01

    Growth mechanics problems require the solution of mass balance equations that include supply terms and account for mass exchanges among constituents of a mixture. Though growth may often be accompanied by a variety of concomitant phenomena that increase modeling complexity, such as solid matrix deformation, evolving traction-free configurations, cell division, and active cell contraction, it is important to distinguish these accompanying phenomena from the fundamental growth process that consists of deposition or removal of mass from the solid matrix. Therefore, the objective of this study is to present a canonical problem of growth, namely, dissolution of a rigid solid matrix in a solvent. This problem illustrates a case of negative growth (loss of mass) of the solid in a mixture framework that includes three species, a solid, a solvent, and a solute, where the solute is the product of the solid dissolution. By analyzing both volumetric and surface dissolutions, the two fundamental modes of growth are investigated within the unified framework of mixture theory.

  20. Surface-assisted laser desorption ionization mass spectrometry techniques for application in forensics.

    Science.gov (United States)

    Guinan, Taryn; Kirkbride, Paul; Pigou, Paul E; Ronci, Maurizio; Kobus, Hilton; Voelcker, Nicolas H

    2015-01-01

    Matrix-assisted laser desorption ionization (MALDI) mass spectrometry (MS) is an excellent analytical technique for the rapid and sensitive analysis of macromolecules (>700 Da), such as peptides, proteins, nucleic acids, and synthetic polymers. However, the detection of smaller organic molecules with masses below 700 Da using MALDI-MS is challenging due to the appearance of matrix adducts and matrix fragment peaks in the same spectral range. Recently, nanostructured substrates have been developed that facilitate matrix-free laser desorption ionization (LDI), contributing to an emerging analytical paradigm referred to as surface-assisted laser desorption ionization (SALDI) MS. Since SALDI enables the detection of small organic molecules, it is rapidly growing in popularity, including in the field of forensics. At the same time, SALDI also holds significant potential as a high throughput analytical tool in roadside, work place and athlete drug testing. In this review, we discuss recent advances in SALDI techniques such as desorption ionization on porous silicon (DIOS), nano-initiator mass spectrometry (NIMS) and nano assisted laser desorption ionization (NALDI™) and compare their strengths and weaknesses with particular focus on forensic applications. These include the detection of illicit drug molecules and their metabolites in biological matrices and small molecule detection from forensic samples including banknotes and fingerprints. Finally, the review highlights recent advances in mass spectrometry imaging (MSI) using SALDI techniques. © 2014 Wiley Periodicals, Inc.

  1. Quantitative analysis of fragrance in selectable one dimensional or two dimensional gas chromatography-mass spectrometry with simultaneous detection of multiple detectors in single injection.

    Science.gov (United States)

    Tan, Hui Peng; Wan, Tow Shi; Min, Christina Liew Shu; Osborne, Murray; Ng, Khim Hui

    2014-03-14

    A selectable one-dimensional ((1)D) or two-dimensional ((2)D) gas chromatography-mass spectrometry (GC-MS) system coupled with flame ionization detector (FID) and olfactory detection port (ODP) was employed in this study to analyze perfume oil and fragrance in shower gel. A split/splitless (SSL) injector and a programmable temperature vaporization (PTV) injector are connected via a 2-way splitter of capillary flow technology (CFT) in this selectable (1)D/(2)D GC-MS/FID/ODP system to facilitate liquid sample injections and thermal desorption (TD) for stir bar sorptive extraction (SBSE) technique, respectively. The dual-linked injectors set-up enable the use of two different injector ports (one at a time) in single sequence run without having to relocate the (1)D capillary column from one inlet to another. Target analytes were separated in (1)D GC-MS/FID/ODP and followed by further separation of co-elution mixture from (1)D in (2)D GC-MS/FID/ODP in single injection without any instrumental reconfiguration. A (1)D/(2)D quantitative analysis method was developed and validated for its repeatability - tR; calculated linear retention indices (LRI); response ratio in both MS and FID signal, limit of detection (LOD), limit of quantitation (LOQ), as well as linearity over a concentration range. The method was successfully applied in quantitative analysis of perfume solution at different concentration level (RSD≤0.01%, n=5) and shower gel spiked with perfume at different dosages (RSD≤0.04%, n=5) with good recovery (96-103% for SSL injection; 94-107% for stir bar sorptive extraction-thermal desorption (SBSE-TD). Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Mass spectrometric method for the determination of the stable isotopic content of nitrous oxide by the technique of direct injection

    International Nuclear Information System (INIS)

    Rahn, T.; Wahlen, M.

    2002-01-01

    A method for the direct isotopic analysis of N 2 O has been developed for VG-Prism H dynamic dual inlet stable isotope mass spectrometer. Tests have shown extreme sensitivity to contamination by carbon dioxide with a dependence of 6.8 per mille per % CO 2 for δ 15 N and 12.4 per mille per % CO 2 for δ 18 O. Trace amounts of CO 2 have proven difficult to eliminate, particularly for small sample sizes. In order to ensure accurate analyses an indicator of CO 2 contamination must be monitored and corrections applied when necessary. We have found that ions with mass to charge ratios of 12 and 22 are excellent proxies for CO 2 contamination. Empirical relationships between these indicator species and CO 2 contamination are documented which allow for corrections to be applied to raw data. Additional corrections required due to the presence of isobaric molecules containing 17 O are described. Issues of standardization are discussed and sample handling procedures described. Finally, these methods and corrections are applied to a suite of stratospheric air samples. (author)

  3. Heat and mass transfer in magnetohydrodynamic Casson fluid over an exponentially permeable stretching surface

    Directory of Open Access Journals (Sweden)

    C.S.K. Raju

    2016-03-01

    Full Text Available In this study we analyzed the flow, heat and mass transfer behavior of Casson fluid past an exponentially permeable stretching surface in presence of thermal radiation, magneticfield, viscous dissipation, heat source and chemical reaction. We presented dual solutions by comparing the results of the Casson fluid with the Newtonian fluid. The governing partial nonlinear differential equations of the flow, heat and mass transfer are transformed into ordinary differential equations by using similarity transformation and solved numerically by using Matlab bvp4c package. The effects of various non-dimensional governing parameters on velocity, temperature and concentration profiles are discussed and presented graphically. Also, the friction factor, Nusselt and Sherwood numbers are analyzed and presented in tabular form for both Casson and Newtonian fluids separately. Under some special conditions the results of the present study have an excellent agreement with existing studies for both Casson and Newtonian fluid cases.

  4. Improving Surface Mass Balance Over Ice Sheets and Snow Depth on Sea Ice

    Science.gov (United States)

    Koenig, Lora Suzanne; Box, Jason; Kurtz, Nathan

    2013-01-01

    Surface mass balance (SMB) over ice sheets and snow on sea ice (SOSI) are important components of the cryosphere. Large knowledge gaps remain in scientists' abilities to monitor SMB and SOSI, including insufficient measurements and difficulties with satellite retrievals. On ice sheets, snow accumulation is the sole mass gain to SMB, and meltwater runoff can be the dominant single loss factor in extremely warm years such as 2012. SOSI affects the growth and melt cycle of the Earth's polar sea ice cover. The summer of 2012 saw the largest satellite-recorded melt area over the Greenland ice sheet and the smallest satellite-recorded Arctic sea ice extent, making this meeting both timely and relevant.

  5. Secondary ion mass spectrometric signal enhancement of phosphatidylcholine dioleoyl on enlarged nanoparticles surface

    Science.gov (United States)

    Gulin, A.; Mochalova, M.; Denisov, N.; Nadtochenko, V.

    2014-10-01

    A silicon wafer surface coverage of nanoparticles (NPs) can enhance the L-α-phosphatidylcholine dioleoyl (DOPC) signal intensity in time-of-flight secondary ion mass spectrometry (TOF-SIMS). A ToF-SIMS mass spectrometer was used with a pulsed primary beam of focused 30 keV Bi3+ ions. The signal enhancing effect has been studied for metallic (Ag, Au, Pb), semiconductor (TiO2), dielectric (SiO2) and hybrid (Au/TiO2NPs, core-shell Au/SiO2) nanoparticles. Ag NPs can attenuate secondary ions signal, whereas all other studied NPs show the signal enhancement. The emission of DOPC lipid secondary ions immobilized on core-shell Au/SiO2NPs was enhanced up to 42 times. This technique is a simple preparatory method enabling an overall increase in molecular lipid ions.

  6. Ion optics of a new time-of-flight mass spectrometer for quantitative surface analysis

    International Nuclear Information System (INIS)

    Veryovkin, Igor V.; Calaway, Wallis F.; Pellin, Michael J.

    2004-01-01

    A new time-of-flight instrument for quantitative surface analysis was developed and constructed at Argonne National Laboratory. It implements ion sputtering and laser desorption for probing analyzed samples and can operate in regimes of secondary neutral mass spectrometry with laser post-ionization and secondary ion mass spectrometry. The instrument incorporates two new ion optics developments: (1) 'push-pull' front end ion optics and (2) focusing and deflecting lens. Implementing these novel elements significantly enhance analytical capabilities of the instrument. Extensive three-dimensional computer simulations of the instrument were conducted in SIMION 3D (c) to perfect its ion optics. The operating principles of the new ion optical systems are described, and a scheme of the new instrument is outlined together with its operating modes

  7. Hot-wire air flow meter for gasoline fuel-injection system. Calculation of air mass in cylinder during transient condition; Gasoline funsha system yo no netsusenshiki kuki ryuryokei. Kato untenji no cylinder juten kukiryo no keisan

    Energy Technology Data Exchange (ETDEWEB)

    Oyama, Y. [Hitachi Car Engineering, Ltd., Tokyo (Japan); Nishimura, Y.; Osuga, M.; Yamauchi, T. [Hitachi, Ltd., Tokyo (Japan)

    1997-10-01

    Air flow characteristics of hot-wire air flow meters for gasoline fuel-injection systems with supercharging and exhaust gas recycle during transient conditions were investigated to analyze a simple method for calculating air mass in cylinder. It was clarified that the air mass in cylinder could be calculated by compensating for the change of air mass in intake system by using aerodynamic models of intake system. 3 refs., 6 figs., 1 tab.

  8. On the local injection of emitted electrons into micrograins on the surface of A{sup III}–B{sup V} semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Zhukov, N. D., E-mail: ndzhukov@rambler.ru; Glukhovskoi, E. G.; Khazanov, A. A. [Saratov State University (Russian Federation)

    2016-06-15

    The characteristics of the injection of electrons into a semiconductor from a microprobe–micrograin nanogap are investigated with a tunneling microscope in the mode of field emission into locally selected surface microcrystals of indium antimonide, indium arsenide, and gallium arsenide. The current mechanisms are established and their parameters are determined by comparing the experimental I–V characteristics and those calculated from formulas of current transport. The effect of limitation of the current into the micrograins of indium antimonide and indium arsenide which manifests itself at injection levels exceeding a certain critical value, e.g., 6 × 10{sup 16} cm{sup –3} for indium antimonide and 4 × 10{sup 17} cm{sup –3} for indium arsenide, is discovered. A physical model, i.e., the localization of electrons in the surface area of a micrograin due to their Coulomb interaction, is proposed.

  9. Simultaneous quantification of polar and non-polar volatile organic compounds in water samples by direct aqueous injection-gas chromatography/mass spectrometry.

    Science.gov (United States)

    Aeppli, Christoph; Berg, Michael; Hofstetter, Thomas B; Kipfer, Rolf; Schwarzenbach, René P

    2008-02-15

    A direct aqueous injection-gas chromatography/mass spectrometry (DAI-GC/MS) method for trace analysis of 24 volatile organic compounds (VOCs) in water samples is presented. The method allows for the simultaneous quantification of benzene, toluene, ethyl benzene, and xylenes (BTEX), methyl tert-butyl ether (MTBE), tert-butyl alcohol (TBA), as well as a variety of chlorinated methanes, ethanes, propane, enthenes and benzenes. Applying a liquid film polyethylene glycol or a porous layer open tubular (PLOT) divinylbenzene GC capillary column to separate the water from the VOCs, volumes of 1-10 microL aqueous sample are directly injected into the GC. No enrichment or pretreatment steps are required and sample volumes as low as 100 microL are sufficient for accurate quantification. Method detection limits determined in natural groundwater samples were between 0.07 and 2.8 microg/L and instrument detection limits of VOCs. DAI-GC/MS offers both good accuracy and precision (relative standard deviations VOC concentration measurements in a polluted aquifer. The wide range of detectable compounds and the lack of labor-intensive sample preparation illustrate that the DAI method is robust and easily applicable for the quantification of important organic groundwater contaminants.

  10. Surface acoustic wave nebulization of peptides as a microfluidic interface for mass spectrometry.

    Science.gov (United States)

    Heron, Scott R; Wilson, Rab; Shaffer, Scott A; Goodlett, David R; Cooper, Jonathan M

    2010-05-15

    We describe the fabrication of a surface acoustic wave (SAW) device on a LiNbO(3) piezoelectric transducer for the transfer of nonvolatile analytes to the gas phase at atmospheric pressure (a process referred to as nebulization or atomization). We subsequently show how such a device can be used in the field of mass spectrometry (MS) detection, demonstrating that SAW nebulization (SAWN) can be performed either in a discontinuous or pulsed mode, similar to that for matrix assisted laser desorption ionization (MALDI) or in a continuous mode like electrospray ionization (ESI). We present data showing the transfer of peptides to the gas phase, where ions are detected by MS. These peptide ions were subsequently fragmented by collision-induced dissociation, from which the sequence was assigned. Unlike MALDI mass spectra, which are typically contaminated with matrix ions at low m/z, the SAWN generated spectra had no such interference. In continuous mode, the SAWN plume was sampled on a microsecond time scale by a linear ion trap mass spectrometer and produced multiply charged peptide precursor ions with a charge state distribution shifted to higher m/z compared to an identical sample analyzed by ESI. The SAWN technology also provides the opportunity to re-examine a sample from a flat surface, repeatedly. The process can be performed without the need for capillaries, which can clog, reservoirs, which dilute the sample, and electrodes, which when in direct contact with sample, cause unwanted electrochemical oxidation. In both continuous and pulsed sampling modes, the quality of precursor ion scans and tandem mass spectra of peptides was consistent across the plume's lifetime.

  11. Nonlinear MHD mixed convection flow and heat and mass transfer of first order chemical reaction over a wedge with variable viscosity in the presence of suction or injection

    Directory of Open Access Journals (Sweden)

    Kandasamy R.

    2007-01-01

    Full Text Available In the present study, an analysis is carried out to study the variable viscosity and chemical reaction effects on MHD flow, heat, and mass transfer characteristics in a viscous fluid over a porous wedge in the presence of heat radiation. The wall of the wedge is embedded in a uniform Darcian porous medium in order to allow for possible fluid wall suction or injection. The governing boundary layer equations are written into a dimensionless form by similarity transformations. The transformed coupled nonlinear ordinary differential equations are solved numerically by using the R. K. Gill and shooting methods. The effects of different parameters on the dimensionless velocity, temperature, and concentration profiles are shown graphically. Comparisons with previously published works are performed and excellent agreement between the results is obtained. The results are presented graphically and the conclusion is drawn that the flow field and other quantities of physical interest are significantly influenced by these parameters.

  12. Study the effects of drying processes on chemical compositions in daylily flowers using flow injection mass spectrometric fingerprinting method and chemometrics.

    Science.gov (United States)

    Liu, Wei; Zhao, Yang; Sun, Jianghao; Li, Gaoyang; Shan, Yang; Chen, Pei

    2017-12-01

    Daylily flowers is an important vegetable in eastern Asia, widely used in many dishes. Daylily flowers are usually sold in dried forms in the supermarkets. There are a few method for processing fresh daylily flowers, however, no study has been conducted to analyze the effects of the processing methods in the composition of final products. In the present study, a flow-injection mass spectrometric fingerprinting (FIMS) method in combination with principal component analysis (PCA) was used to differentiate two species of daylily flowers (Mengzi and Chongli) with three different treatments (vacuum freeze drying, solar drying and hot-air drying treatments) for each. The results showed the fast and simple FIMS method could successfully differentiate between species (raw material) and treatments among each species. However, the two species could not be discriminated very well after being processed in hot-air drying treatment. The difference in chemical profiles of species and treatments were discussed. Copyright © 2017. Published by Elsevier Ltd.

  13. Direct large volume injection ultra-high performance liquid chromatography-tandem mass spectrometry determination of artificial sweeteners sucralose and acesulfame in well water.

    Science.gov (United States)

    Wu, Minghuo; Qian, Yichao; Boyd, Jessica M; Hrudey, Steve E; Le, X Chris; Li, Xing-Fang

    2014-09-12

    Acesulfame (ACE) and sucralose (SUC) have become recognized as ideal domestic wastewater contamination indicators. Liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) analysis is commonly used; however, the sensitivity of SUC is more than two orders of magnitude lower than that of ACE, limiting the routine monitoring of SUC. To address this issue, we examined the ESI behavior of both ACE and SUC under various conditions. ACE is ionic in aqueous solution and efficiently produces simple [M-H](-) ions, but SUC produces multiple adduct ions, limiting its sensitivity. The formic acid (FA) adducts of SUC [M+HCOO](-) are sensitively and reproducibly generated under the LC-MS conditions. When [M+HCOO](-) is used as the precursor ion for SUC detection, the sensitivity increases approximately 20-fold compared to when [M-H](-) is the precursor ion. To further improve the limit of detection (LOD), we integrated the large volume injection approach (500μL injection) with ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS), which reduced the method detection limit (MDL) to 0.2ng/L for ACE and 5ng/L for SUC. To demonstrate the applicability of this method, we analyzed 100 well water samples collected in Alberta. ACE was detected in 24 wells at concentrations of 1-1534ng/L and SUC in 8 wells at concentrations of 65-541ng/L. These results suggest that wastewater is the most likely source of ACE and SUC impacts in these wells, suggesting the need for monitoring the quality of domestic well water. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Determination of low-molecular-weight dicarboxylic acids in atmospheric aerosols by injection-port derivatization and gas chromatography-mass spectrometry

    Science.gov (United States)

    Ding, W.; Hsu, C.

    2008-12-01

    Currently, the investigations on aerosol water-soluble organic compounds (WSOCs) formed by burning biomass have become increasingly concerned with the role of these compounds in atmospheric chemistry and their effect on climate, because they have great potential to influence cloud formation, precipitation, and climate on both global and regional scales. Of these compounds, low-molecular weight (LMW) dicarboxylic acids (from C2 to C10) have attracted the most interest because of their properties as specific tracers for the burning of biomass. In this study, a modified injection-port derivatization and gas chromatography - mass spectrometry method was developed and evaluated for rapid determination of LMW dicarboxylic acids in atmospheric aerosol samples. The parameters related to the derivatization process (i.e., type of ion-pair reagent, injection-port temperature and concentration of ion-pair reagent) were optimized. Tetrabutylammonium hydroxide (TBA-OH) dissolved in methanol used as the ion-pair solution gave excellent yield for di-butyl ester low-molecular weight derivatives. Solid-phase extraction method instead of rotary evaporation was used to concentrate analytes from filter extracts. The recovery from filter extracts ranged from 67 to 86% with relative standard deviation (RSD) less than 13%. The concentrations of dicarboxylated C2, C3, C4, C5 and C6-C10 in atmospheric aerosols ranged from 91-240 ng/m3, 11-56 ng/m3, 12-49 ng/m3, 8-35 ng/m3 and n.d. to 17 ng/m3, respectively. Oxalic (C2) acid was the dominant dicarboxylic acids detected in aerosol samples. The total concentrations of the LMW dicarboxylic acids (from C2 to C10) correspond to 2.2 to 2.6% of the total aerosol mass.

  15. Monitoring glacier albedo as a proxy to derive summer and annual surface mass balances from optical remote-sensing data

    Science.gov (United States)

    Davaze, Lucas; Rabatel, Antoine; Arnaud, Yves; Sirguey, Pascal; Six, Delphine; Letreguilly, Anne; Dumont, Marie

    2018-01-01

    Less than 0.25 % of the 250 000 glaciers inventoried in the Randolph Glacier Inventory (RGI V.5) are currently monitored with in situ measurements of surface mass balance. Increasing this archive is very challenging, especially using time-consuming methods based on in situ measurements, and complementary methods are required to quantify the surface mass balance of unmonitored glaciers. The current study relies on the so-called albedo method, based on the analysis of albedo maps retrieved from optical satellite imagery acquired since 2000 by the MODIS sensor, on board the TERRA satellite. Recent studies revealed substantial relationships between summer minimum glacier-wide surface albedo and annual surface mass balance, because this minimum surface albedo is directly related to the accumulation-area ratio and the equilibrium-line altitude. On the basis of 30 glaciers located in the French Alps where annual surface mass balance data are available, our study conducted on the period 2000-2015 confirms the robustness and reliability of the relationship between the summer minimum surface albedo and the annual surface mass balance. For the ablation season, the integrated summer surface albedo is significantly correlated with the summer surface mass balance of the six glaciers seasonally monitored. These results are promising to monitor both annual and summer glacier-wide surface mass balances of individual glaciers at a regional scale using optical satellite images. A sensitivity study on the computed cloud masks revealed a high confidence in the retrieved albedo maps, restricting the number of omission errors. Albedo retrieval artifacts have been detected for topographically incised glaciers, highlighting limitations in the shadow correction algorithm, although inter-annual comparisons are not affected by systematic errors.

  16. Nanofluidic transport over a curved surface with viscous dissipation and convective mass flux

    Energy Technology Data Exchange (ETDEWEB)

    Mehmood, Zaffar; Iqbal, Z.; Azhar, Ehtsham; Maraj, E.N. [HITEC Univ., Taxila (Pakistan). Dept. of Mathematics

    2017-06-01

    This article is a numerical investigation of boundary layer flow of nanofluid over a bended stretching surface. The study is carried out by considering convective mass flux condition. Contribution of viscous dissipation is taken into the account along with thermal radiation. Suitable similarity transformations are employed to simplify the system of nonlinear partial differential equations into a system of nonlinear ordinary differential equations. Computational results are extracted by means of a shooting method embedded with a Runge-Kutta Fehlberg technique. Key findings include that velocity is a decreasing function of curvature parameter K. Moreover, Nusselt number decreases with increase in curvature of the stretching surface while skin friction and Sherwood number enhance with increase in K.

  17. Ultrasensitive probing of the protein resistance of PEG surfaces by secondary ion mass spectrometry

    DEFF Research Database (Denmark)

    Kingshott, P.; McArthur, S.; Thissen, H.

    2002-01-01

    The highly sensitive surface analytical techniques X-ray photoelectron spectroscopy (XPS) and time-of-flight static secondary ion mass spectrometry (ToF-SIMS) were used to test the resistance of poly(ethylene glycol) (PEG) coatings towards adsorption of lysozyme (LYS) and fibronectin (FN). PEG...... temperature to maximise the graft density of the PEG chains. XPS showed that the grafted density of PEG chains was slightly higher on the allylamine surface. XPS detected no adsorption of either protein on either PEG coating. ToF-SIMS analysis, on the other hand, found, in the positive ion spectra, minute...... but statistically significant signals assignable to amino acid fragment ions from both proteins adsorbed to the lower density PEG coating and from LYS but not FN on the higher density PEG coating. Negative ion spectra contained relatively more intense protein fragment ion signals for the lower density PEG coating...

  18. SURFACE BRIGHTNESS PROFILES OF DWARF GALAXIES. II. COLOR TRENDS AND MASS PROFILES

    Energy Technology Data Exchange (ETDEWEB)

    Herrmann, Kimberly A. [Penn State Mont Alto, 1 Campus Drive, Mont Alto, PA 17237 (United States); Hunter, Deidre A. [Lowell Observatory, 1400 West Mars Hill Road, Flagstaff, AZ 86001 (United States); Elmegreen, Bruce G., E-mail: kah259@psu.edu, E-mail: dah@lowell.edu, E-mail: bge@us.ibm.com [IBM T. J. Watson Research Center, 1101 Kitchawan Road, Yorktown Heights, NY 10598 (United States)

    2016-06-01

    In this second paper of a series, we explore the B  −  V , U  −  B , and FUV−NUV radial color trends from a multi-wavelength sample of 141 dwarf disk galaxies. Like spirals, dwarf galaxies have three types of radial surface brightness profiles: (I) single exponential throughout the observed extent (the minority), (II) down-bending (the majority), and (III) up-bending. We find that the colors of (1) Type I dwarfs generally become redder with increasing radius, unlike spirals which have a blueing trend that flattens beyond ∼1.5 disk scale lengths, (2) Type II dwarfs come in six different “flavors,” one of which mimics the “U” shape of spirals, and (3) Type III dwarfs have a stretched “S” shape where the central colors are flattish, become steeply redder toward the surface brightness break, then remain roughly constant beyond, which is similar to spiral Type III color profiles, but without the central outward bluing. Faint (−9 >  M{sub B}  > −14) Type II dwarfs tend to have continuously red or “U” shaped colors and steeper color slopes than bright (−14 >  M{sub B}  > −19) Type II dwarfs, which additionally have colors that become bluer or remain constant with increasing radius. Sm dwarfs and BCDs tend to have at least some blue and red radial color trend, respectively. Additionally, we determine stellar surface mass density (Σ) profiles and use them to show that the break in Σ generally remains in Type II dwarfs (unlike Type II spirals) but generally disappears in Type III dwarfs (unlike Type III spirals). Moreover, the break in Σ is strong, intermediate, and weak in faint dwarfs, bright dwarfs, and spirals, respectively, indicating that Σ may straighten with increasing galaxy mass. Finally, the average stellar surface mass density at the surface brightness break is roughly 1−2  M {sub ⊙} pc{sup −2} for Type II dwarfs but higher at 5.9  M {sub ⊙} pc{sup −2} or 27  M {sub ⊙} pc{sup −2} for

  19. Atmospheric summer teleconnections and Greenland Ice Sheet surface mass variations: insights from MERRA-2

    International Nuclear Information System (INIS)

    Lim, Young-Kwon; Schubert, Siegfried D; Molod, Andrea M; Cullather, Richard I; Zhao, Bin; Nowicki, Sophie M J; Lee, Jae N; Velicogna, Isabella

    2016-01-01

    The relationship between leading atmospheric teleconnection patterns and Greenland Ice Sheet (GrIS) temperature, precipitation, and surface mass balance (SMB) are investigated for the last 36 summers (1979–2014) based on Modern-Era Retrospective analysis for Research and Applications version 2 reanalyses. The results indicate that the negative phase of both the North Atlantic Oscillation (NAO) and Arctic Oscillation, associated with warm and dry conditions for the GrIS, lead to SMB decreases within 0–1 months. Furthermore, the positive phase of the East Atlantic (EA) pattern often lags the negative NAO, reflecting a dynamical linkage between these modes that acts to further enhance the warm and dry conditions over the GrIS, leading to a favorable environment for enhanced surface mass loss. The development of a strong negative NAO in combination with a strong positive EA in recent years leads to significantly larger GrIS warming compared to when the negative NAO occurs in combination with a negative or weak positive EA (0.69 K versus 0.13 K anomaly). During 2009 and 2011, weakened (as compared to conditions during the severe surface melt cases of 2010 and 2012) local high pressure blocking produced colder northerly flow over the GrIS inhibiting warming despite the occurrence of a strong negative NAO, reflecting an important role for the EA during those years. In particular, the EA acts with the NAO to enhance warming in 2010 and 2012, and weaken high pressure blocking in 2009 and 2011. In general, high pressure blocking primarily impacts the western areas of the GrIS via advective temperature increases, while changes in net surface radiative fluxes account for both western and eastern GrIS temperature changes. (letter)

  20. Surface deformation induced by water pumping for construction of Mass Rapid Transportation in Taipei basin

    Science.gov (United States)

    Hu, J. C.; Wu, P. C.; Tung, H.; Tsai, M. C.

    2017-12-01

    In 1968, there were 2,200 wells in the Taipei Basin used for water supply to meet the requirement of high population density. The overuse of ground water lead to the land subsidence rate up to 5 cm/yr. Although the government had already begun to limit groundwater pumping since 1968, the groundwater in the Taipei Basin demonstrated temporary fluctuation induced by pumping water for large deep excavation site or engineering usage. The previous study based on precise leveling suggested that the surface deformation was highly associated with the recovery of water level. In 1989, widespread uplift dominated in Taipei basin due to the recovery of ground water Table. In this study, we use 37 high-resolution X-band COSMO-SkyMed radar images from May 2011 to April 2015 to characterize deformation pattern in the period of construction of Mass Rapid Transportation (MRT). We also use 30 wells and 380 benchmarks of precise leveling in Taipei basin to study the correlation of surface deformation and change of ground water table. The storability is roughly constant across most of the aquifer with values between 0.8 x 10-4 and 1.3 x 10-3. Moreover, the high water pumping in two major aquifers, Jignme and Wuku Foramtions, before the underground construction for MRT led to inflict surface deformation and no time delay observed for surface deformation during the water pumping. It implies that the poro-elastic effect dominates in major aquifers in Taipei basin.

  1. Investigating the relationship between seismicity and fluid injection in the Barnett Shale, Texas using coupled poroelastic model and surface deformation data

    Science.gov (United States)

    Zhai, G.; Shirzaei, M.

    2017-12-01

    Across the Barnett Shale, Texas a noticeable increase in seismic activity was observed during 2007 and 2015, which was accompanied by high volume injection at several nearby disposal wells. Many studies focused on the positive correlation between injection rate at individual wells and the adjacent seismicity, suggesting that seismicity is triggered or induced due to increased pore fluid pressure associated with fluid injection in hydraulically connected geological units. However, investigating temporal evolution of total volume of injected fluid and concurrent earthquakes in a larger area indicates more complex patterns, requiring a more comprehensive analysis of the spatiotemporal evolution of coupled poroelastic stress and pore fluid pressure. In this study, we created a coupled poroelastic model to simulate large scale spatiotemporal evolution of pore pressure, poroelastic stresses, and Coulomb failure stress in the Barnett Shale using injection time series of 96 high-volume injection wells spanning from 2007 to 2015. We additionally account for a layered poroelastic medium, where its parameters are set up using geological maps and seismic tomographic data sets. Fault orientations and relevant frictional properties are also extracted from published literatures. We further integrate observation of surface deformation obtained from interferometric processing of 16 ALOS L-Band SAR images to optimize rock hydraulic diffusivity and constrain the extent to which fluid may migrate. The preliminary modeling result shows that poroelastic stress is only 10% of pore pressure. However, the superimposition of these two effects is spatially and temporally responsible for the occurrence of earthquakes in the Barnett Shale. Also, not all area with increased Coulomb failure stress experiences elevated seismicity, suggesting possible heterogeneous background tectonic stresses, lacking pre-existing faults, and/or heterogeneous fault orientations.

  2. Experimental survey on percutaneous injection of calcium phosphate cement in preventing the articular surface collapsing secondary to avascular necrosis of femoral head

    International Nuclear Information System (INIS)

    Hou Changlong; Lv Weifu; Zhang Xuebin; Wang Weiyu; Zhang Xingming

    2007-01-01

    Objective: To study the technical way for animal model of ANFH with TAE (transcatheter arterial embolization)and to observe the image and pathologic changes of percutaneous injection with CPC (Calcium Phosphate Cement)in preventing the articular surface collapsing secondary to ANFH (avascular necrosis of femoral head)in pigs and its feasibility and safety. Methods: Branch arteries of the pig's left femoral head were embolized with woolly threads. Twenty pigs were randomly divided into A and B groups, and after about 1 month changes were assessed by imagings. Group A(n=8)was served as control of model contrast group, with only TAE and then surveyed the avascular necrosis features of femoral head by imaging together with pathologic and histologic examinations. Group B (n=12) was designated as percutaneous injection with CPC for interventional treatment group of ANFH at the stage Ficat II. Results: The animal models of ANFH in early stage were established by embolization of feeding arteries. In Group A, bone collapse occurred in 1.5 months after TAE, with imaging features of femoral head necrosis aggravated gradually. In group B, technical success of percutaneous injection with CPC was high and technical criteria included precise injection time, vigorous percutaneous fixing of bone, suitable proportion of CPC powder to liquid. CT scan of femoral head with injection CPC showed that it diffused well. Volume of bone trabecula (TBV)and percentage of bone lacuna (PBL)at unit area under microscopy were also inspected in two groups. TBV and PBL of two groups were compared in different special times and calculated especially for group B (P<0.05). Conclusion: The percutaneous injection of CPC to femoral head is a quite safe and effective palliative therapy for ANFH in early stage. (authors)

  3. Effects of sample injection amount and time-of-flight mass spectrometric detection dynamic range on metabolome analysis by high-performance chemical isotope labeling LC-MS.

    Science.gov (United States)

    Zhou, Ruokun; Li, Liang

    2015-04-06

    The effect of sample injection amount on metabolome analysis in a chemical isotope labeling (CIL) liquid chromatography-mass spectrometry (LC-MS) platform was investigated. The performance of time-of-flight (TOF) mass spectrometers with and without a high-dynamic-range (HD) detection system was compared in the analysis of (12)C2/(13)C2-dansyl labeled human urine samples. An average of 1635 ± 21 (n = 3) peak pairs or putative metabolites was detected using the HD-TOF-MS, compared to 1429 ± 37 peak pairs from a conventional or non-HD TOF-MS. In both instruments, signal saturation was observed. However, in the HD-TOF-MS, signal saturation was mainly caused by the ionization process, while in the non-HD TOF-MS, it was caused by the detection process. To extend the MS detection range in the non-HD TOF-MS, an automated switching from using (12)C to (13)C-natural abundance peaks for peak ratio calculation when the (12)C peaks are saturated has been implemented in IsoMS, a software tool for processing CIL LC-MS data. This work illustrates that injecting an optimal sample amount is important to maximize the metabolome coverage while avoiding the sample carryover problem often associated with over-injection. A TOF mass spectrometer with an enhanced detection dynamic range can also significantly increase the number of peak pairs detected. In chemical isotope labeling (CIL) LC-MS, relative metabolite quantification is done by measuring the peak ratio of a (13)C2-/(12)C2-labeled peak pair for a given metabolite present in two comparative samples. The dynamic range of peak ratio measurement does not need to be very large, as only subtle changes of metabolite concentrations are encountered in most metabolomic studies where relative metabolome quantification of different groups of samples is performed. However, the absolute concentrations of different metabolites can be very different, requiring a technique to provide a wide detection dynamic range to allow the detection of as

  4. Ozone-surface interactions: Investigations of mechanisms, kinetics, mass transport, and implications for indoor air quality

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, Glenn Charles [Univ. of California, Berkeley, CA (United States)

    1999-12-01

    In this dissertation, results are presented of laboratory investigations and mathematical modeling efforts designed to better understand the interactions of ozone with surfaces. In the laboratory, carpet and duct materials were exposed to ozone and measured ozone uptake kinetics and the ozone induced emissions of volatile organic compounds. To understand the results of the experiments, mathematical methods were developed to describe dynamic indoor aldehyde concentrations, mass transport of reactive species to smooth surfaces, the equivalent reaction probability of whole carpet due to the surface reactivity of fibers and carpet backing, and ozone aging of surfaces. Carpets, separated carpet fibers, and separated carpet backing all tended to release aldehydes when exposed to ozone. Secondary emissions were mostly n-nonanal and several other smaller aldehydes. The pattern of emissions suggested that vegetable oils may be precursors for these oxidized emissions. Several possible precursors and experiments in which linseed and tung oils were tested for their secondary emission potential were discussed. Dynamic emission rates of 2-nonenal from a residential carpet may indicate that intermediate species in the oxidation of conjugated olefins can significantly delay aldehyde emissions and act as reservoir for these compounds. The ozone induced emission rate of 2-nonenal, a very odorous compound, can result in odorous indoor concentrations for several years. Surface ozone reactivity is a key parameter in determining the flux of ozone to a surface, is parameterized by the reaction probability, which is simply the probability that an ozone molecule will be irreversibly consumed when it strikes a surface. In laboratory studies of two residential and two commercial carpets, the ozone reaction probability for carpet fibers, carpet backing and the equivalent reaction probability for whole carpet were determined. Typically reaction probability values for these materials were 10

  5. Re-assessment of recent (2008–2013 surface mass balance over Dome Argus, Antarctica

    Directory of Open Access Journals (Sweden)

    Minghu Ding

    2016-04-01

    Full Text Available At Dome Argus, East Antarctica, the surface mass balance (SMB from 2008 to 2013 was evaluated using 49 stakes installed across a 30×30 km area. Spatial analysis showed that at least 12 and 20 stakes are needed to obtain reliable estimates of SMB at local scales (a few hundred square metres and regional scales (tens of square kilometres, respectively. The estimated annual mean SMB was 22.9±5.9 kg m−2 yr−1, including a net loss by sublimation of −2.22±0.02 kg m−2 yr−1 and a mass gain by deposition of 1.37±0.01 kg m−2 yr−1. Therefore, ca. 14.3% of precipitation was modified after deposition, which should be considered when interpreting snow or ice core records produced by future drilling projects. The surface snow density and SMB in the western portion of Dome Argus are higher than in other areas, and these differences are likely related to the katabatic wind, which is strengthened by topography in this sector. A new digital elevation model (DEM of Dome Argus was generated, confirming that both peaks of the dome can be considered as the summit of the East Antarctic Ice Sheet. Findings from this study should be valuable for validating SMB estimates obtained from regional climate models and DEMs established using remote-sensing data.

  6. Upper limit of the muon-neutrino mass and charged-pion mass from the momentum analysis of a surface muon beam

    International Nuclear Information System (INIS)

    Kettle, P.R.

    1996-01-01

    Using a surface muon beam and a magnetic spectrometer equipped with a position-sensitive detector, we have measured the muon momentum from pion decay at rest π + →μ + ν μ , to be p μ + =(29.79200±0.00011)MeV/c. This value together with the muon mass and the favoured pion mass leads to an upper limit of 0.17 MeV (90%CL) for the muon-neutrino mass. (author) 4 figs., 5 refs

  7. Upper limit of the muon-neutrino mass and charged-pion mass from the momentum analysis of a surface muon beam

    Energy Technology Data Exchange (ETDEWEB)

    Kettle, P.R. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1996-11-01

    Using a surface muon beam and a magnetic spectrometer equipped with a position-sensitive detector, we have measured the muon momentum from pion decay at rest {pi}{sup +}{yields}{mu}{sup +}{nu}{sub {mu}}, to be p{sub {mu}{sup +}}=(29.79200{+-}0.00011)MeV/c. This value together with the muon mass and the favoured pion mass leads to an upper limit of 0.17 MeV (90%CL) for the muon-neutrino mass. (author) 4 figs., 5 refs.

  8. Graphene Surface Acoustic Wave Sensor for Simultaneous Detection of Charge and Mass.

    Science.gov (United States)

    Okuda, Satoshi; Ono, Takao; Kanai, Yasushi; Ikuta, Takashi; Shimatani, Masaaki; Ogawa, Shinpei; Maehashi, Kenzo; Inoue, Koichi; Matsumoto, Kazuhiko

    2018-01-26

    We have combined a graphene field-effect transistor (GFET) and a surface acoustic wave (SAW) sensor on a LiTaO 3 substrate to create a graphene surface acoustic wave (GSAW) sensor. When a SAW propagates in graphene, an acoustoelectric current (I A ) flows between two attached electrodes. This current has unique electrical characteristics, having both positive and negative peak values with respect to the electrolyte-gate voltage (V Eg ) in solution. We found that I A is controlled by V Eg and the amplitude of the SAW. It was also confirmed that the GSAW sensor detects changes of electrical charge in solution like conventional GFET sensors. Furthermore, the detection of amino-group-modified microbeads was performed by employing a GSAW sensor in a phthalate buffer solution at pH 4.1. The hole current peak shifted to the lower left in the I A -V Eg characteristics. The left shift was caused by charge detection by the GFET and can be explained by an increase of amino groups that have positive charges at pH 4.1. In contrast, the downward shift is thought to be due to a reduction in the amplitude of the propagating SAW because of an increase in the mass loading of microbeads. This mass loading was detected by the SAW sensor. Thus, we have demonstrated that the GSAW sensor is a transducer capable of the simultaneous detection of charge and mass, which indicates that it is an attractive platform for highly sensitive and multifunctional solution sensing.

  9. An Ultra-High Performance Liquid Chromatographic-Tandem Mass Spectrometric Method for the Determination of Sinomenine in Human Plasma after Transdermal Delivery of the Zhengqing Fengtongning Injection

    Directory of Open Access Journals (Sweden)

    Tingbo Chen

    2015-04-01

    Full Text Available A sensitive, precise and selective ultra-high performance liquid chromatography method coupled with triple-quadrupole mass spectrometry was developed and validated for the determination of trace amounts of sinomenine (ng/mL in minute volumes of human plasma. Fifty microliter plasma samples were precipitated using methanol to extract sinomenine. Separation was carried out on a C18 column with a water and acetonitrile mobile phase gradient with formic acid as an additive. The mass spectrometry data were obtained in the positive ion mode, and the transition of multiple reactions was monitored at m/z 330.2→181.0 for sinomenine quantification. The working assay range for sinomenine was linear from 0.1173 to 15.02 ng/mL with the lower limit of quantification of 0.1173 ng/mL. The precision and accuracy of the method was less than 15% in intra-day and inter-day experiments with a matrix effect of less than 6.5%. After validation, the quantitative method was applied to analyze sinomenine levels in human plasma after transdermal delivery of the Zhengqing Fengtongning Injection. The results showed that some samples contained sinomenine within the concentration range 0.4131–4.407 ng/mL.

  10. Pressure-assisted electrokinetic injection for on-line enrichment in capillary electrophoresis-mass spectrometry: a sensitive method for measurement of ten haloacetic acids in drinking water.

    Science.gov (United States)

    Zhang, Huijuan; Zhu, Jiping; Aranda-Rodriguez, Rocio; Feng, Yong-Lai

    2011-11-07

    Haloacetic acids (HAAs) are by-products of the chlorination of drinking water containing natural organic matter and bromide. A simple and sensitive method has been developed for determination of ten HAAs in drinking water. The pressure-assisted electrokinetic injection (PAEKI), an on-line enrichment technique, was employed to introduce the sample into a capillary electrophoresis (CE)-electrospray ionization-tandem mass spectrometry system (ESI-MS/MS). HAAs were monitored in selected reaction monitoring mode. With 3 min of PAEKI time, the ten major HAAs (HAA10) in drinking water were enriched up to 20,000-fold into the capillary without compromising resolution. A simple solid phase clean-up method has been developed to eliminate the influence of ionic matrices from drinking water on PAEKI. Under conditions optimized for mass spectrometry, PAEKI and capillary electrophoresis, detection limits defined as three times ratio of signal to noise have been achieved in a range of 0.013-0.12 μg L(-1) for ten HAAs in water sample. The overall recoveries for all ten HAAs in drinking water samples were between 76 and 125%. Six HAAs including monochloro- (MCAA), dichloro- (DCAA), trichloro- (TCAA), monobromo- (MBAA), bromochloro- (BCAA), and bromodichloroacetic acids (BDCAA) were found in tap water samples collected. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.

  11. Atmospheric river impacts on Greenland Ice Sheet surface melt and mass balance

    Science.gov (United States)

    Mattingly, K.; Mote, T. L.

    2017-12-01

    Mass loss from the Greenland Ice Sheet (GrIS) has accelerated during the early part of the 21st Century. Several episodes of widespread GrIS melt in recent years have coincided with intense poleward moisture transport by atmospheric rivers (ARs), suggesting that variability in the frequency and intensity of these events may be an important driver of the surface mass balance (SMB) of the GrIS. ARs may contribute to GrIS surface melt through the greenhouse effect of water vapor, the radiative effects of clouds, condensational latent heating within poleward-advected air masses, and the energy provided by liquid precipitation. However, ARs may also provide significant positive contributions to GrIS SMB through enhanced snow accumulation. Prior research on the role of ARs in Arctic climate has consisted of case studies of ARs associated with major GrIS melt events or examined the effects of poleward moisture flux on Arctic sea ice. In this study, a long-term (1979-2016) record of intense moisture transport events affecting Greenland is compiled using a conventional AR identification algorithm as well as a self-organizing map (SOM) classification applied to integrated water vapor transport (IVT) data from several atmospheric reanalysis datasets. An analysis of AR effects on GrIS melt and SMB is then performed with GrIS surface melt data from passive microwave satellite observations and the Modèle Atmosphérique Régional (MAR) regional climate model. Results show that meltwater production is above normal during and after AR impact days throughout the GrIS during all seasons, with surface melt enhanced most by strong (> 85th percentile IVT) and extreme (> 95th percentile IVT) ARs. This relationship holds at the seasonal scale, as the total amount of water vapor transported to the GrIS by ARs is significantly greater during above-normal melt seasons. ARs exert a more complex influence on SMB. Normal (< 85th percentile IVT) ARs generally do not have a substantial impact on

  12. Controlled Dissolution of Surface Layers for Elemental Analysis by Inductively Coupled Plasma-Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Lorge, Susan Elizabeth [Iowa State Univ., Ames, IA (United States)

    2007-01-01

    Determining the composition of thin layers is increasingly important for a variety of industrial materials such as adhesives, coatings and microelectronics. Secondary ion mass spectrometry (SIMS), Auger electron spectroscopy (AES), X-ray photoelectron spectroscopy (XPS), glow discharge optical emission spectroscopy (GDOES), glow discharge mass spectrometry (GDMS), and laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) are some of the techniques that are currently employed for the direct analysis of the sample surface. Although these techniques do not suffer from the contamination problems that often plague sample dissolution studies, they do require matrix matched standards for quantification. Often, these standards are not readily available. Despite the costs of clean hoods, Teflon pipette tips and bottles, and pure acids, partial sample dissolution is the primary method used in the semiconductor industry to quantify surface impurities. Specifically, vapor phase decomposition (VPD) coupled to ICP-MS or total reflection x-ray fluorescence (TXRF) provides elemental information from the top most surface layers at detection sensitivities in the 107-1010atoms/cm2 range. The ability to quantify with standard solutions is a main advantage of these techniques. Li and Houk applied a VPD-like technique to steel. The signal ratio of trace element to matrix element was used for quantification. Although controlled dissolution concentrations determined for some of the dissolved elements agreed with the certified values, concentrations determined for refractory elements (Ti, Nb and Ta) were too low. LA-ICP-MS and scanning electron microscopy (SEM) measurements indicated that carbide grains distributed throughout the matrix were high in these refractory elements. These elements dissolved at a slower rate than the matrix element, Fe. If the analyte element is not removed at a rate similar to the matrix element a true

  13. Extending and refining the mass surface around $^{208}$Pb by high-precision Penning-trap mass spectrometry with ISOLTRAP

    CERN Multimedia

    Herfurth, F; Stora, T; Blaum, K; Beck, D; Kowalska, M; Schwarz, S; Stanja, J; Herlert, A J; Yamaguchi, T

    We propose high-precision mass spectrometry of nuclides around the doubly magic $^{208}$Pb. On the neutron-rich side, we aim to extend the knowledge of Fr, At, Hg, and Au masses to study the robustness of the N = 126 shell closure and to provide mass data necessary for modeling the rapid-neutron-capture process. On the proton-rich side, we aim at high-resolution mass spectrometry of selected Au, At, and Fr isotopes to verify the predicted existence of very low-lying isomeric states. The proposal will make use of newly-available laser-ionization schemes for Au and At. Finally, the recently implemented multi-reflection time-of-flight mass separator for auxiliary isobaric purification now allows measurements which were not feasible before.

  14. Dynamics of 1.55 μm Wavelength Single-Mode Vertical-Cavity Surface-Emitting Laser Output under External Optical Injection

    Directory of Open Access Journals (Sweden)

    Kyong Hon Kim

    2012-01-01

    Full Text Available We review the temporal dynamics of the laser output spectrum and polarization state of 1.55 μm wavelength single-mode (SM vertical-cavity surface-emitting lasers (VCSELs induced by external optical beam injection. Injection of an external continuous-wave laser beam to a gain-switched SM VCSEL near the resonance wavelength corresponding to its main polarization-mode output was critical for improvement of its laser pulse generation characteristics, such as pulse timing-jitter reduction, linewidth narrowing, pulse amplitude enhancement, and pulse width shortening. Pulse injection of pulse width shorter than the cavity photon lifetime into the SM VCSEL in the orthogonal polarization direction with respect to its main polarization mode caused temporal delay of the polarization recovery after polarization switching (PS, and its delay was found to be the minimum at an optimized bias current. Polarization-mode bistability was observed even in the laser output of an SM VCSEL of a standard circularly cylindrical shape and used for all-optical flip-flop operations with set and reset injection pulses of very low pulse energy of order of the 3.5~4.5 fJ.

  15. Response surface modeling to predict fluid loss from beef strip loins and steaks injected with salt and phosphate with or without a dehydrated beef protein water binding adjunct.

    Science.gov (United States)

    Lowder, Austin C; Goad, Carla L; Lou, Xingqiu; Morgan, J Brad; Koh, Chern Lin; Deakins, Alisha Parsons; Mireles DeWitt, Christina A

    2013-05-01

    This study was conducted using response surface methodology to predict fluid loss from injected beef strip steaks as influenced by levels of salt and sodium phosphates (SP) in the injection brine. Also, a beef-based dehydrated beef protein (DBP) water binding ingredient was evaluated. Paired U.S. select beef strip loins were quartered before being injected with 110% of initial weight with brines containing various concentrations of salt and SP (CON) or salt, SP and 5% DBP. Steaks were sliced, overwrapped and stored in the dark for 4d. Purge values ranged from 0.6% to 4.6% for CON and 0.3% to 2.1% for DBP. Fluid losses when accounting for the fluid lost from injection to slicing were as high as 6.8% for CON brines, but only 2.8% for DBP brines. The equations generated here and the DBP product could help producers achieve acceptable purge while reducing sodium use. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Modelling non-adiabatic effects in H{sub 3}{sup +}: Solution of the rovibrational Schrödinger equation with motion-dependent masses and mass surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Mátyus, Edit, E-mail: matyus@chem.elte.hu [Institute of Chemistry, Eötvös University, P.O. Box 32, H-1518 Budapest 112 (Hungary); Szidarovszky, Tamás [MTA-ELTE Research Group on Complex Chemical Systems, Pázmány Péter sétány 1/A, H-1117 Budapest (Hungary); Császár, Attila G., E-mail: csaszar@chem.elte.hu [Institute of Chemistry, Eötvös University, P.O. Box 32, H-1518, Budapest 112, Hungary and MTA-ELTE Research Group on Complex Chemical Systems, Pázmány Péter sétány 1/A, H-1117 Budapest (Hungary)

    2014-10-21

    Introducing different rotational and vibrational masses in the nuclear-motion Hamiltonian is a simple phenomenological way to model rovibrational non-adiabaticity. It is shown on the example of the molecular ion H{sub 3}{sup +}, for which a global adiabatic potential energy surface accurate to better than 0.1 cm{sup −1} exists [M. Pavanello, L. Adamowicz, A. Alijah, N. F. Zobov, I. I. Mizus, O. L. Polyansky, J. Tennyson, T. Szidarovszky, A. G. Császár, M. Berg et al., Phys. Rev. Lett. 108, 023002 (2012)], that the motion-dependent mass concept yields much more accurate rovibrational energy levels but, unusually, the results are dependent upon the choice of the embedding of the molecule-fixed frame. Correct degeneracies and an improved agreement with experimental data are obtained if an Eckart embedding corresponding to a reference structure of D{sub 3h} point-group symmetry is employed. The vibrational mass of the proton in H{sub 3}{sup +} is optimized by minimizing the root-mean-square (rms) deviation between the computed and recent high-accuracy experimental transitions. The best vibrational mass obtained is larger than the nuclear mass of the proton by approximately one third of an electron mass, m{sub opt,p}{sup (v)}=m{sub nuc,p}+0.31224 m{sub e}. This optimized vibrational mass, along with a nuclear rotational mass, reduces the rms deviation of the experimental and computed rovibrational transitions by an order of magnitude. Finally, it is shown that an extension of the algorithm allowing the use of motion-dependent masses can deal with coordinate-dependent mass surfaces in the rovibrational Hamiltonian, as well.

  17. Annual and Seasonal Glacier-Wide Surface Mass Balance Quantified from Changes in Glacier Surface State: A Review on Existing Methods Using Optical Satellite Imagery

    Directory of Open Access Journals (Sweden)

    Antoine Rabatel

    2017-05-01

    Full Text Available Glaciers are one of the terrestrial essential climate variables (ECVs as they respond very sensitively to climate change. A key driver of their response is the glacier surface mass balance that is typically derived from field measurements. It deserves to be quantified over long time scales to better understand the accumulation and ablation processes at the glacier surface and their relationships with inter-annual changes in meteorological conditions and long-term climate changes. Glaciers with in situ monitoring of surface mass balance are scarce at the global scale, and satellite remote sensing provides a powerful tool to increase the number of monitored glaciers. In this study, we present a review of three optical remote sensing methods developed to quantify seasonal and annual glacier surface mass balances. These methodologies rely on the multitemporal monitoring of the end-of-summer snow line for the equilibrium-line altitude (ELA method, the annual cycle of glacier surface albedo for the albedo method and the mapping of the regional snow cover at the seasonal scale for the snow-map method. Together with a presentation of each method, an application is illustrated. The ELA method shows promising results to quantify annual surface mass balance and to reconstruct multi-decadal time series. The other two methods currently need a calibration on the basis of existing in situ data; however, a generalization of these methods (without calibration could be achieved. The two latter methods show satisfying results at the annual and seasonal scales, particularly for the summer surface mass balance in the case of the albedo method and for the winter surface mass balance in the case of the snow-map method. The limits of each method (e.g., cloud coverage, debris-covered glaciers, monsoon-regime and cold glaciers, their complementarities and the future challenges (e.g., automating of the satellite images processing, generalization of the methods needing

  18. Properties of the surface snow in Princess Elizabeth Land, East Antarctica - climate and non-climate dependent variability of the surface mass balance and stable water isotopic composition

    Science.gov (United States)

    Vladimirova, D.; Ekaykin, A.; Lipenkov, V.; Popov, S. V.; Petit, J. R.; Masson-Delmotte, V.

    2017-12-01

    Glaciological and meteorological observations conducted during the past four decades in Princess Elizabeth Land, East Antarctica, are compiled. The database is used to investigate spatial patterns of surface snow isotopic composition and surface mass balance, including detailed information near subglacial lake Vostok. We show diverse relationships between snow isotopic composition and surface temperature. In the most inland part (elevation 3200-3400 m a.s.l.), surface snow isotopic composition varies independently from surface temperature, and is closely related to the distance to the open water source (with a slope of 0.98±0.17 ‰ per 100 km). Surface mass balance values are higher along the ice sheet slope, and relatively evenly distributed inland. The minimum values of snow isotopic composition and surface mass balance are identified in an area XX km southwestward from Vostok station. The spatial distribution of deuterium excess delineates regions influenced by the Indian Ocean and Pacific Ocean air masses, with Vostok area being situated close to their boundary. Anomalously high deuterium excess values are observed near Dome A, suggesting high kinetic fractionation for its moisture source, or specifically high post-deposition artifacts. The dataset is available for further studies such as the assessment of skills of general circulation or regional atmospheric models, and the search for the oldest ice.

  19. Sensitivity of Greenland Ice Sheet surface mass balance to surface albedo parameterization: a study with a regional climate model

    Directory of Open Access Journals (Sweden)

    J. H. van Angelen

    2012-10-01

    Full Text Available We present a sensitivity study of the surface mass balance (SMB of the Greenland Ice Sheet, as modeled using a regional atmospheric climate model, to various parameter settings in the albedo scheme. The snow albedo scheme uses grain size as a prognostic variable and further depends on cloud cover, solar zenith angle and black carbon concentration. For the control experiment the overestimation of absorbed shortwave radiation (+6% at the K-transect (west Greenland for the period 2004–2009 is considerably reduced compared to the previous density-dependent albedo scheme (+22%. To simulate realistic snow albedo values, a small concentration of black carbon is needed, which has strongest impact on melt in the accumulation area. A background ice albedo field derived from MODIS imagery improves the agreement between the modeled and observed SMB gradient along the K-transect. The effect of enhanced meltwater retention and refreezing is a decrease of the albedo due to an increase in snow grain size. As a secondary effect of refreezing the snowpack is heated, enhancing melt and further lowering the albedo. Especially in a warmer climate this process is important, since it reduces the refreezing potential of the firn layer that covers the Greenland Ice Sheet.

  20. Testosterone Injection

    Science.gov (United States)

    ... typical male characteristics. Testosterone injection works by supplying synthetic testosterone to replace the testosterone that is normally ... as a pellet to be injected under the skin.Testosterone injection may control your symptoms but will ...

  1. Assessing modeled Greenland surface mass balance in the GISS Model E2 and its sensitivity to surface albedo

    Science.gov (United States)

    Alexander, Patrick; LeGrande, Allegra N.; Koenig, Lora S.; Tedesco, Marco; Moustafa, Samiah E.; Ivanoff, Alvaro; Fischer, Robert P.; Fettweis, Xavier

    2016-04-01

    The surface mass balance (SMB) of the Greenland Ice Sheet (GrIS) plays an important role in global sea level change. Regional Climate Models (RCMs) such as the Modèle Atmosphérique Régionale (MAR) have been employed at high spatial resolution with relatively complex physics to simulate ice sheet SMB. Global climate models (GCMs) incorporate less sophisticated physical schemes and provide outputs at a lower spatial resolution, but have the advantage of modeling the interaction between different components of the earth's oceans, climate, and land surface at a global scale. Improving the ability of GCMs to represent ice sheet SMB is important for making predictions of future changes in global sea level. With the ultimate goal of improving SMB simulated by the Goddard Institute for Space Studies (GISS) Model E2 GCM, we compare simulated GrIS SMB against the outputs of the MAR model and radar-derived estimates of snow accumulation. In order to reproduce present-day climate variability in the Model E2 simulation, winds are constrained to match the reanalysis datasets used to force MAR at the lateral boundaries. We conduct a preliminary assessment of the sensitivity of the simulated Model E2 SMB to surface albedo, a parameter that is known to strongly influence SMB. Model E2 albedo is set to a fixed value of 0.8 over the entire ice sheet in the initial configuration of the model (control case). We adjust this fixed value in an ensemble of simulations over a range of 0.4 to 0.8 (roughly the range of observed summer GrIS albedo values) to examine the sensitivity of ice-sheet-wide SMB to albedo. We prescribe albedo from the Moderate Resolution Imaging Spectroradiometer (MODIS) MCD43A3 v6 to examine the impact of a more realistic spatial and temporal variations in albedo. An age-dependent snow albedo parameterization is applied, and its impact on SMB relative to observations and the RCM is assessed.

  2. DFT study of anthocyanidin and anthocyanin pigments for Dye-Sensitized Solar Cells: Electron injecting from the excited states and adsorption onto TiO2 (anatase) surface

    Science.gov (United States)

    Marcano, Emildo

    2017-06-01

    We explored, the absorption spectra, excited states and electronic injection parameters of anthocyanidin and anthocyanin pigments using the level of theory (TD)CAM-B3LYP/6-31+G(d,p). For the most isolated dyes, the distribution pattern of HOMO and LUMO spreads over the whole molecules, which lead an efficient electronic delocalization. The calculated light harvesting efficiencies (LHEs) are all near unity. Methoxy group in peonidin molecule lead the largest oscillator strength and LHE. The presence of water lead a higher spontaneous electronic inject process, with ΔGinject average of -1.14 eV. The ΔGinject order is peonidin anthocyanin-(TiO2)30 complex was calculated to be from 17 to 24 eV, indicating both, the strong interactions between the dyes and the anatase (TiO2) surface and stronger electronic coupling strengths of the anthocyanin-(TiO2)30 complex, which corresponded to higher observed η. The HOMO and LUMO shape showed the electrons delocalized predominantly on the anthocyanin structure while the LUMO + 1 shape is localized into the (TiO2)30 surface. Therefore, we expected a electronic injection from HOMO to LUMO + 1 in the anthocyanin-(TiO2)30 adsorption complex, after the light absorption.

  3. [Optimization of vacuum belt drying process of Gardeniae Fructus in Reduning injection by Box-Behnken design-response surface methodology].

    Science.gov (United States)

    Huang, Dao-sheng; Shi, Wei; Han, Lei; Sun, Ke; Chen, Guang-bo; Wu Jian-xiong; Xu, Gui-hong; Bi, Yu-an; Wang, Zhen-zhong; Xiao, Wei

    2015-06-01

    To optimize the belt drying process conditions optimization of Gardeniae Fructus extract from Reduning injection by Box-Behnken design-response surface methodology, on the basis of single factor experiment, a three-factor and three-level Box-Behnken experimental design was employed to optimize the drying technology of Gardeniae Fructus extract from Reduning injection. With drying temperature, drying time, feeding speed as independent variables and the content of geniposide as dependent variable, the experimental data were fitted to a second order polynomial equation, establishing the mathematical relationship between the content of geniposide and respective variables. With the experimental data analyzed by Design-Expert 8. 0. 6, the optimal drying parameter was as follows: the drying temperature was 98.5 degrees C , the drying time was 89 min, the feeding speed was 99.8 r x min(-1). Three verification experiments were taked under this technology and the measured average content of geniposide was 564. 108 mg x g(-1), which was close to the model prediction: 563. 307 mg x g(-1). According to the verification test, the Gardeniae Fructus belt drying process is steady and feasible. So single factor experiments combined with response surface method (RSM) could be used to optimize the drying technology of Reduning injection Gardenia extract.

  4. Seaweed allelopathy against coral: surface distribution of a seaweed secondary metabolite by imaging mass spectrometry.

    Science.gov (United States)

    Andras, Tiffany D; Alexander, Troy S; Gahlena, Asiri; Parry, R Mitchell; Fernandez, Facundo M; Kubanek, Julia; Wang, May D; Hay, Mark E

    2012-10-01

    Coral reefs are in global decline, with seaweeds increasing as corals decrease. Although seaweeds inhibit coral growth, recruitment, and survivorship, the mechanism of these interactions is poorly understood. Here, we used field experiments to show that contact with four common seaweeds induces bleaching on natural colonies of Porites rus. Controls in contact with inert, plastic mimics of seaweeds did not bleach, suggesting seaweed effects resulted from allelopathy rather than shading, abrasion, or physical contact. Bioassay-guided fractionation of the hydrophobic extract from the red alga Phacelocarpus neurymenioides revealed a previously characterized antibacterial metabolite, neurymenolide A, as the main allelopathic agent. For allelopathy of lipid-soluble metabolites to be effective, the compounds would need to be deployed on algal surfaces where they could transfer to corals on contact. We used desorption electrospray ionization mass spectrometry (DESI-MS) to visualize and quantify neurymenolide A on the surface of P. neurymenioides, and we found the molecule on all surfaces analyzed, with highest concentrations on basal portions of blades.

  5. In situ analysis of ion-induced polymer surface modification using secondary ion mass spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Okuji, Shigeto, E-mail: s-okuji@post.lintec.co.jp [Lintec Corporation, 5-14-42 Nishiki-cho, Warabi, Saitama 335-0005 (Japan); Quantum Beam Unit, National Institute for Materials Science, 3-13 Sakura, Tsukuba, Ibaraki 305-0003 (Japan); University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8577 (Japan); Kitazawa, Hideaki [Quantum Beam Unit, National Institute for Materials Science, 3-13 Sakura, Tsukuba, Ibaraki 305-0003 (Japan); Takeda, Yoshihiko, E-mail: TAKEDA.Yoshihiko@nims.go.jp [Quantum Beam Unit, National Institute for Materials Science, 3-13 Sakura, Tsukuba, Ibaraki 305-0003 (Japan); University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8577 (Japan)

    2016-06-15

    We have investigated the surface modification process consisting of ion irradiation immediately followed by exposure to ambient gas for three types of polymers having the same main chain, −C−C−, but different atoms bound to the main chain, using in situ secondary ion mass spectroscopy. The polymers’ surface was irradiated with 30 keV Au ions at a total fluence for up to 1 × 10{sup 17} cm{sup −2} and exposed to ambient gas in a ultra-high-vacuum chamber (1 × 10{sup −6} Pa) for 30 min after the ion irradiation. Low density polyethylene mainly exhibited a hydrogen dissociation during the ion irradiation and a recombination with hydrogen atoms by the exposure, polytetrafluoroethylene mainly showed a main chain scission and no recombination during the exposure, and polyvinylidene difluoride lost hydrogen and fluorine atoms by the ion irradiation and partially recombined with hydrogen and fluorine atoms upon the exposure. The deposited energy density on the polymer surfaces reflects the dependence of the modification on the incident ion species, Au or Ga ions.

  6. Understanding the structure, dynamics, and mass transport properties of self assembling peptide hydrogels for injectable, drug delivery applications

    Science.gov (United States)

    Branco, Monica Cristina

    hydrogels as a function of peptide sequence and concentration. Changes in nanoscale dynamics and structure inherently lead to substantial differences in bulk properties, such as the elastic modulus and network mesh size. Learning how the material properties of the gels influence the transport rate of therapeutics through the hydrogel is essential to the development of delivery vehicles. The remainder of the thesis focuses on correlating the mesh sizes of MAX1 and MAX8 gels to the diffusion and mass transport properties of model dextran and protein probes. Here, work is centered on how peptide charge and concentration, as well as probe structure, in particular hydrodynamic diameter and charge, dictate the temporal release of model probes from the peptide hydrogels. Experiments include self diffusion studies and bulk release experiments with model dextrans and proteins from gels before and after syringe delivery. Overall, this thesis will demonstrate the importance of understanding material properties from the nanoscale up to the macroscale for application based design. With this approach, better and specific development of self-assembling peptide materials can be achieved, allowing for the rational engineering of peptide sequences to form hydrogels appropriate for specific drug delivery applications.

  7. 21st century changes in the surface mass balance of the Greenland ice sheet simulated with the global model CESM

    Science.gov (United States)

    Vizcaíno, M.; Lipscomb, W. H.; Van den Broeke, M.

    2012-04-01

    We present here the first projections of 21st century surface mass balance change of the Greenland ice sheet simulated with the Community Earth System Model (CESM). CESM is a fully-coupled, global climate model developed at many research centers and universities, primarily in the U.S. The model calculates the surface mass balance in the land component (the Community Land Model, CLM), at the same resolution as the atmosphere (1 degree), with an energy-balance scheme. The snow physics included in CLM for non-glaciated surfaces (SNiCAR model, Flanner and Zender, 2005) are used over the ice sheet. The surface mass balance is calculated for 10 elevation classes, and then downscaled to the grid of the ice sheet model (5 km in this case) via vertical linear interpolation between elevation classes combined with horizontal bilinear interpolation. The ice sheet topography is fixed at present-day values for the simulations presented here. The use of elevation classes reduces computational costs while giving results that reproduce well the mass balance gradients at the steep margins of the ice sheet. The simulated present-day surface mass balance agrees well with results from regional models. We focus on the regional model RACMO (Ettema et al. 2009) to compare the results on 20th-century surface mass balance evolution and two-dimensional patterns. The surface mass balance of the ice sheet under RCP8.5. forcing becomes negative in the last decades of the 21st century. The equilibrium line becomes ~500 m higher on average. Accumulation changes are positive in the accumulation zone. We examine changes in refreezing, accumulation, albedo, surface fluxes, and the timing of the melt season.

  8. Slurry sampling flow injection chemical vapor generation inductively coupled plasma mass spectrometry for the determination of trace Ge, As, Cd, Sb, Hg and Bi in cosmetic lotions

    International Nuclear Information System (INIS)

    Chen, Wei-Ni; Jiang, Shiuh-Jen; Chen, Yen-Ling; Sahayam, A.C.

    2015-01-01

    Highlights: • Determination of Ge, As, Cd, Sb, Hg and Bi in cosmetic lotions in a single run. • Accurate analysis using isotope dilution and standard addition methods. • Vapor generation ICP-MS yielded superior detection limits compared to ETV-ICP-MS. • No sample dissolution increased sample through put. • Analysis of GBW09305 Cosmetic (Cream) reference material for accuracy. - Abstract: A slurry sampling inductively coupled plasma mass spectrometry (ICP-MS) method has been developed for the determination of Ge, As, Cd, Sb, Hg and Bi in cosmetic lotions using flow injection (FI) vapor generation (VG) as the sample introduction system. A slurry containing 2% m/v lotion, 2% m/v thiourea, 0.05% m/v L-cysteine, 0.5 μg mL −1 Co(II), 0.1% m/v Triton X-100 and 1.2% v/v HCl was injected into a VG-ICP-MS system for the determination of Ge, As, Cd, Sb, Hg and Bi without dissolution and mineralization. Because the sensitivities of the analytes in the slurry and that of aqueous solution were quite different, an isotope dilution method and a standard addition method were used for the determination. This method has been validated by the determination of Ge, As, Cd, Sb, Hg and Bi in GBW09305 Cosmetic (Cream) reference material. The method was also applied for the determination of Ge, As, Cd, Sb, Hg and Bi in three cosmetic lotion samples obtained locally. The analysis results of the reference material agreed with the certified value and/or ETV-ICP-MS results. The detection limit estimated from the standard addition curve was 0.025, 0.1, 0.2, 0.1, 0.15, and 0.03 ng g −1 for Ge, As, Cd, Sb, Hg and Bi, respectively, in original cosmetic lotion sample

  9. Slurry sampling flow injection chemical vapor generation inductively coupled plasma mass spectrometry for the determination of trace Ge, As, Cd, Sb, Hg and Bi in cosmetic lotions

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Wei-Ni [Department of Chemistry, National Sun Yat-sen University, Kaohsiung 80424, Taiwan (China); Jiang, Shiuh-Jen, E-mail: sjjiang@faculty.nsysu.edu.tw [Department of Chemistry, National Sun Yat-sen University, Kaohsiung 80424, Taiwan (China); Department of Medical Laboratory Science and Biotechnology, Kaohsiung Medical University, Kaohsiung 80708, Taiwan (China); Chen, Yen-Ling [Department of Fragrance and Cosmetic Science, Kaohsiung Medical University, Kaohsiung 80708, Taiwan (China); Sahayam, A.C. [National Centre for Compositional Characterisation of Materials (CCCM), Hyderabad (India)

    2015-02-20

    Highlights: • Determination of Ge, As, Cd, Sb, Hg and Bi in cosmetic lotions in a single run. • Accurate analysis using isotope dilution and standard addition methods. • Vapor generation ICP-MS yielded superior detection limits compared to ETV-ICP-MS. • No sample dissolution increased sample through put. • Analysis of GBW09305 Cosmetic (Cream) reference material for accuracy. - Abstract: A slurry sampling inductively coupled plasma mass spectrometry (ICP-MS) method has been developed for the determination of Ge, As, Cd, Sb, Hg and Bi in cosmetic lotions using flow injection (FI) vapor generation (VG) as the sample introduction system. A slurry containing 2% m/v lotion, 2% m/v thiourea, 0.05% m/v L-cysteine, 0.5 μg mL{sup −1} Co(II), 0.1% m/v Triton X-100 and 1.2% v/v HCl was injected into a VG-ICP-MS system for the determination of Ge, As, Cd, Sb, Hg and Bi without dissolution and mineralization. Because the sensitivities of the analytes in the slurry and that of aqueous solution were quite different, an isotope dilution method and a standard addition method were used for the determination. This method has been validated by the determination of Ge, As, Cd, Sb, Hg and Bi in GBW09305 Cosmetic (Cream) reference material. The method was also applied for the determination of Ge, As, Cd, Sb, Hg and Bi in three cosmetic lotion samples obtained locally. The analysis results of the reference material agreed with the certified value and/or ETV-ICP-MS results. The detection limit estimated from the standard addition curve was 0.025, 0.1, 0.2, 0.1, 0.15, and 0.03 ng g{sup −1} for Ge, As, Cd, Sb, Hg and Bi, respectively, in original cosmetic lotion sample.

  10. Injection moulding antireflective nanostructures

    DEFF Research Database (Denmark)

    Christiansen, Alexander Bruun; Clausen, Jeppe Sandvik; Mortensen, N. Asger

    We present a method for injection moulding antireflective nanostructures on large areas, for high volume production. Nanostructured black silicon masters were fabricated by mask-less reactive ion etching, and electroplated with nickel. The nickel shim was antistiction coated and used in an inject......We present a method for injection moulding antireflective nanostructures on large areas, for high volume production. Nanostructured black silicon masters were fabricated by mask-less reactive ion etching, and electroplated with nickel. The nickel shim was antistiction coated and used...... in an injection moulding process, to fabricate the antireflective surfaces. The cycle-time was 35 s. The injection moulded structures had a height of 125 nm, and the visible spectrum reflectance of injection moulded black polypropylene surfaces was reduced from 4.5±0.5% to 2.5±0.5%. The gradient of the refractive...

  11. In situ investigation of titanium nitride surface dynamics: The role of surface and bulk mass transport processes

    Science.gov (United States)

    Bareno, Javier

    NaCl-structure TiN and related transition-metal (TM) nitrides are widely used as hard wear-resistant coatings on cutting tools, diffusion-barriers in microelectronic devices, corrosion-resistant layers on mechanical components, and abrasion-resistant thin films on optics and architectural glass. Since the elastic and physical properties of TiN are highly anisotropic, controlling the microstructural and surface morphological evolution of polycrystalline TM nitride films is important for all of the above applications. In this thesis, I used in-situ high-temperature low-energy electron microscopy (LEEM) to gain insight into film growth and microstructure development dynamics by studying mass-transport processes occurring during annealing of three dimensional (3D) structures on TiN surfaces. Additionally, in order to extend the current understanding of nanostructure development in binary nitride films to more complex ternary TM-nitride-based nanocomposites, I employed in-situ scanning tunneling microscopy (STM) and low-energy electron diffraction (LEED), as well as ab-initio modeling, to investigate the atomic structure of the SiNx/TiN heterointerfaces which control the properties of SiNx-TiN nanocomposites. The LEEM studies of mass transport on TiN(111) focus on two specific surface morphologies which are observed to be present during growth of TiN single-crystals. (1) I investigated the temperature-dependent coarsening/decay kinetics of three-dimensional TiN island mounds on large (>1000 A) atomically-flat terraces; showing that TiN(111) steps are highly permeable and exhibit strong repulsive temperature-dependent step-step interactions that vary from 0.03 eV-A at 1559 K to 0.76 eV-A at 1651 K. (2) I studied the nucleation and growth of spiral steps originating at surface-terminated screw dislocations; I developed a model of spiral growth relating the emission rate of point defects from the bulk to the temperature-dependent spiral rotation frequency o(T); and I

  12. Surface tailoring of newly developed amorphous Znsbnd Sisbnd O thin films as electron injection/transport layer by plasma treatment: Application to inverted OLEDs and hybrid solar cells

    Science.gov (United States)

    Yang, Hongsheng; Kim, Junghwan; Yamamoto, Koji; Xing, Xing; Hosono, Hideo

    2018-03-01

    We report a unique amorphous oxide semiconductor Znsbnd Sisbnd O (a-ZSO) which has a small work function of 3.4 eV for as-deposited films. The surface modification of a-ZSO thin films by plasma treatments is examined to apply it to the electron injection/transport layer of organic devices. It turns out that the energy alignment and exciton dissociation efficiency at a-ZSO/organic semiconductor interface significantly changes by choosing different gas (oxygen or argon) for plasma treatments (after a-ZSO was exposed to atmospheric environment for 5 days). In situ ultraviolet photoelectron spectroscopy (UPS) measurement reveals that the work function of a-ZSO is increased to 4.0 eV after an O2-plasma treatment, while the work function of 3.5 eV is recovered after an Ar-plasma treatment which indicates this treatment is effective for surface cleaning. To study the effects of surface treatments to device performance, OLEDs and hybrid polymer solar cells with O2-plasma or Ar-plasma treated a-ZSO are compared. Effects of these surface treatments on performance of inverted OLEDs and hybrid polymer solar cells are examined. Ar-plasma treated a-ZSO works well as the electron injection layer in inverted OLEDs (Alq3/a-ZSO) because the injection barrier is small (∼ 0.1 eV). On the other hands, O2-plasma treated a-ZSO is more suitable for application to hybrid solar cells which is benefiting from higher exciton dissociation efficiency at polymer (P3HT)/ZSO interface.

  13. Elevation change of the Greenland Ice Sheet due to surface mass balance and firn processes, 1960-2014

    NARCIS (Netherlands)

    Kuipers Munneke, P.; Ligtenberg, S. R M; Noël, B. P Y; Howat, I. M.; Box, J. E.; Mosley-Thompson, E.; McConnell, J. R.; Steffen, K.; Harper, J. T.; Das, S. B.; Van Den Broeke, M. R.

    2015-01-01

    Observed changes in the surface elevation of the Greenland Ice Sheet are caused by ice dynamics, basal elevation change, basal melt, surface mass balance (SMB) variability, and by compaction of the overlying firn. The last two contributions are quantified here using a firn model that includes

  14. Greenland Surface Mass Balance as Simulated by the Community Earth System Model. Part II: Twenty-First-Century Changes

    NARCIS (Netherlands)

    Vizcaino, M.; Lipscomb, W.H.; Sacks, W.J.; van den Broeke, M.R.

    2014-01-01

    This study presents the first twenty-first-century projections of surface mass balance (SMB) changes for the Greenland Ice Sheet (GIS) with the Community Earth System Model (CESM), which includes a new ice sheet component. For glaciated surfaces, CESM includes a sophisticated calculation of energy

  15. Determination of platinum surface contamination in veterinary and human oncology centres using inductively coupled plasma mass spectrometry

    NARCIS (Netherlands)

    Janssens, T.; Brouwers, E. E M; de Vos, J. P.; de Vries, N.; Schellens, J. H M; Beijnen, J. H.

    2015-01-01

    The objective of this study was to determine the surface contamination with platinum-containing antineoplastic drugs in veterinary and human oncology centres. Inductively coupled plasma mass spectrometry was used to measure platinum levels in surface samples. In veterinary and human oncology

  16. Assessment of the surface mass balance along the K-transect (Greenland ice sheet) from satellite-derived albedos

    NARCIS (Netherlands)

    Oerlemans, J.; Greuell, W.

    This paper explores the potential of using satellite-derived albedos to estimate the surface mass balance of the Kangerlussuaq transect (K-transect; Greenland ice sheet). We first retrieved surface albedos from Advanced Very High Resolution Radar data by using, among other techniques, a new

  17. Mass balance of the Greenland ice sheet - a study of ICESat data, surface density and firn compaction modelling

    DEFF Research Database (Denmark)

    Sørensen, L. S.; Simonsen, Sebastian Bjerregaard; Nielsen, K.

    2010-01-01

    in estimating the mass balance of the Greenland ice sheet. We find firn dynamics and surface densities to be important factors in deriving the mass loss from remote sensing altimetry. The volume change derived from ICESat data is corrected for firn compaction, vertical bedrock movement and an intercampaign...... elevation bias in the ICESat data. Subsequently, the corrected volume change is converted into mass change by surface density modelling. The firn compaction and density models are driven by a dynamically downscaled simulation of the HIRHAM5 regional climate model using ERA-Interim reanalysis lateral......ICESat has provided surface elevation measurements of the ice sheets since the launch in January 2003, resulting in a unique data set for monitoring the changes of the cryosphere. Here we present a novel method for determining the mass balance of the Greenland ice sheet derived from ICESat...

  18. Measurement of elemental speciation by liquid chromatography -- inductively coupled plasma mass spectrometry (LC-ICP-MS) with the direct injection nebulizer (DIN)

    Energy Technology Data Exchange (ETDEWEB)

    Shum, Sam [Iowa State Univ., Ames, IA (United States)

    1993-05-01

    This thesis is divided into 4 parts: elemental speciation, speciation of mercury and lead compounds by microbore column LC-ICP-MS with direct injection nebulization, spatially resolved measurements of size and velocity distributions of aerosol droplets from a direct injection nebulizer, and elemental speciation by anion exchange and size exclusion chromatography with detection by ICP-MS with direct injection nebulization.

  19. Surface Mass Balance Distributions: Downscaling of Coarse Climates to drive Ice Sheet Models realistically

    Science.gov (United States)

    Rodehacke, Christian; Mottram, Ruth; Langen, Peter; Madsen, Marianne; Yang, Shuting; Boberg, Fredrik; Christensen, Jens

    2017-04-01

    The surface mass balance (SMB) is the most import boundary conditions for the state of glaciers and ice sheets. Hence its representation in numerical model simulations is of highest interest for glacier, ice cap and ice sheet modeling efforts. While descent SMB distributions of the current climate could be interfered with the help of various observation techniques and platforms, its construction for older past and future climates relies on input from spatially coarse resolved global climate models or reconstructions. These coarse SMB estimates with a footprint in the order of 100 km could hardly resolve the marginal ablations zones where the Greenland ice sheets, for instance, loses snow and ice. We present a downscaling method that is based on the physical calculation of the surface mass and energy balance. By the consequent application of universal and computationally cheap parameterizations we get an astonishing good representation of the SMB distribution including its marginal ablation zone. However the method has its limitations; for example wrong accumulation rates due to an insufficient precipitation field leaves its imprint on the SMB distribution. Also the still not satisfactory description of the bare ice albedo, in particular, in parts of Greenland is a challenge. We inspect our Greenland SMB fields' for various forcings and compare them with some widely used reference fields in the community to highlight the weakness and strength of our approach. We use the ERA-Interim reanalyzes period starting in 1979 directly as well as dynamically downscaled by our regional climate model HIRHAM (5 km resolution). Also SMB distributions obtained from the climate model EC-Earth with a resolution of T159 (approx. 125 km resolution in Greenland) are used either directly or downscaled with our regional climate model HIRHAM. Model-based End-of-the-century SMB estimates give an outlook of the future.

  20. Greenland ice sheet surface mass balance: evaluating simulations and making projections with regional climate models

    Directory of Open Access Journals (Sweden)

    J. G. L. Rae

    2012-11-01

    Full Text Available Four high-resolution regional climate models (RCMs have been set up for the area of Greenland, with the aim of providing future projections of Greenland ice sheet surface mass balance (SMB, and its contribution to sea level rise, with greater accuracy than is possible from coarser-resolution general circulation models (GCMs. This is the first time an intercomparison has been carried out of RCM results for Greenland climate and SMB. Output from RCM simulations for the recent past with the four RCMs is evaluated against available observations. The evaluation highlights the importance of using a detailed snow physics scheme, especially regarding the representations of albedo and meltwater refreezing. Simulations with three of the RCMs for the 21st century using SRES scenario A1B from two GCMs produce trends of between −5.5 and −1.1 Gt yr−2 in SMB (equivalent to +0.015 and +0.003 mm sea level equivalent yr−2, with trends of smaller magnitude for scenario E1, in which emissions are mitigated. Results from one of the RCMs whose present-day simulation is most realistic indicate that an annual mean near-surface air temperature increase over Greenland of ~ 2°C would be required for the mass loss to increase such that it exceeds accumulation, thereby causing the SMB to become negative, which has been suggested as a threshold beyond which the ice sheet would eventually be eliminated.

  1. Diffusive mass transport in agglomerated glassy fallout from a near-surface nuclear test

    Science.gov (United States)

    Weisz, David G.; Jacobsen, Benjamin; Marks, Naomi E.; Knight, Kim B.; Isselhardt, Brett H.; Matzel, Jennifer E.

    2018-02-01

    Aerodynamically-shaped glassy fallout is formed when vapor phase constituents from the nuclear device are incorporated into molten carriers (i.e. fallout precursor materials derived from soil or other near-field environmental debris). The effects of speciation and diffusive transport of condensing constituents are not well defined in models of fallout formation. Previously we reported observations of diffuse micrometer scale layers enriched in Na, Fe, Ca, and 235U, and depleted in Al and Ti, at the interfaces of agglomerated fallout objects. Here, we derive the timescales of uranium mass transport in such fallout as it cools from 2500 K to 1500 K by applying a 1-dimensional planar diffusion model to the observed 235U/30Si variation at the interfaces. By modeling the thermal transport between the fireball and the carrier materials, the time of mass transport is calculated to be <0.6 s, <1 s, <2 s, and <3.5 s for fireball yields of 0.1 kt, 1 kt, 10 kt, and 100 kt respectively. Based on the calculated times of mass transport, a maximum temperature of deposition of uranium onto the carrier material of ∼2200 K is inferred (1σ uncertainty of ∼200 K). We also determine that the occurrence of micrometer scale layers of material enriched in relatively volatile Na-species as well as more refractory Ca-species provides evidence for an oxygen-rich fireball based on the vapor pressure of the two species under oxidizing conditions. These results represent the first application of diffusion-based modeling to derive material transport, thermal environments, and oxidation-speciation in near-surface nuclear detonation environments.

  2. Gaussian Process Model for Antarctic Surface Mass Balance and Ice Core Site Selection

    Science.gov (United States)

    White, P. A.; Reese, S.; Christensen, W. F.; Rupper, S.

    2017-12-01

    Surface mass balance (SMB) is an important factor in the estimation of sea level change, and data are collected to estimate models for prediction of SMB on the Antarctic ice sheet. Using Favier et al.'s (2013) quality-controlled aggregate data set of SMB field measurements, a fully Bayesian spatial model is posed to estimate Antarctic SMB and propose new field measurement locations. Utilizing Nearest-Neighbor Gaussian process (NNGP) models, SMB is estimated over the Antarctic ice sheet. An Antarctic SMB map is rendered using this model and is compared with previous estimates. A prediction uncertainty map is created to identify regions of high SMB uncertainty. The model estimates net SMB to be 2173 Gton yr-1 with 95% credible interval (2021,2331) Gton yr-1. On average, these results suggest lower Antarctic SMB and higher uncertainty than previously purported [Vaughan et al. (1999); Van de Berg et al. (2006); Arthern, Winebrenner and Vaughan (2006); Bromwich et al. (2004); Lenaerts et al. (2012)], even though this model utilizes significantly more observations than previous models. Using the Gaussian process' uncertainty and model parameters, we propose 15 new measurement locations for field study utilizing a maximin space-filling, error-minimizing design; these potential measurements are identied to minimize future estimation uncertainty. Using currently accepted Antarctic mass balance estimates and our SMB estimate, we estimate net mass loss [Shepherd et al. (2012); Jacob et al. (2012)]. Furthermore, we discuss modeling details for both space-time data and combining field measurement data with output from mathematical models using the NNGP framework.

  3. Analysis of supramolecular surface nanostructures using secondary ion mass spectrometry (poster)

    International Nuclear Information System (INIS)

    Halaszova, S.; Velic, D.

    2013-01-01

    Our system consists of host molecules β-cyclodextrin (C 42 H 70 O 35 ), of implemented Iron nanoparticles (guest). Whole supramolecular complex is placed on a gold substrate. In our project we work with monotiolated β-cyclodextrin (C 42 H 70 O 34 S), consisting of seven α-D-1-4 glucopyranose units. Cyclodextrins have been selected deliberately because of their ability to form inclusion complexes .They are also capable of forming structures similar to self-assembly monolayers. To study the formation of these supramolecular surface nanostructures mass secondary ion spectrometry is used. With this technique fragmentation of monotiolated β-cyclodextrin and the presence of the supramolecular complex on a gold surface can be examined. The observed fragments of monotiolated cyclodextrines films can be divided into three groups: Au X H Y S Z , fragments originating from cyclodextrin molecules associated with Au. Fragments as (C 42 H 70 O 34 S)Na + , (C 42 H 70 O 35 )Na + and (AuC 42 H 69 O 34 S)Na + were identified as well as fragments thereof in cationized form with K + . The main objective of the project is a detailed study and preparation of supramolecular nanostructures consisting of complex guest-host monotiolated β-cyclodextrin host-iron), and a gold substrate. (Authors)

  4. Greenland ice sheet surface mass-balance modeling in a 131-Yr perspective, 1950-2080

    DEFF Research Database (Denmark)

    Mernild, Sebastian H.; Liston, Glen E.; Hiemstra, Christopher A.

    2010-01-01

    and correct RCM output data before they were used as input for SnowModel. Satellite observations and independent SMB studies were used to validate the SnowModel output and confirmthemodel's robustness. The authors simulated an ~90% increase in end-of-summer surface melt extent (0.483 × 106 km2) from 1950......Fluctuations in the Greenland ice sheet (GrIS) surface mass balance (SMB) and freshwater influx to the surrounding oceans closely follow climate fluctuations and are of considerable importance to the global eustatic sea level rise.Astate-of-the-art snow-evolution modeling system(SnowModel) was used...... to 2080 and a melt index (above 2000-m elevation) increase of 138% (1.96 × 106 km2 × days). The greatest difference in melt extent occurred in the southern part of theGrIS, and the greatest changes in the number of melt dayswere seen in the eastern part of the GrIS (~50%-70%) and were lowest in the west...

  5. Analysis of personal care products on model skin surfaces using DESI and PADI ambient mass spectrometry.

    Science.gov (United States)

    Salter, Tara L; Green, Felicia M; Faruqui, Nilofar; Gilmore, Ian S

    2011-08-21

    Two ambient ionisation techniques, desorption electrospray ionisation (DESI) and plasma assisted desorption ionisation (PADI), have been used to analyse personal care products (PCPs) on fixed fibroblast cell surfaces. The similarities and differences between the two techniques for this type of analysis have been explored in various ways. Here, we show the results of DESI and PADI analysis of individual PCP ingredients as well as the analysis of these as complex creams on model skin surfaces, with minimal sample preparation. Typically, organosiloxanes and small molecules were detected from the creams. A study of the morphological damage of the fibroblast cells by the two ionisation techniques showed that for a less than 10% reduction in cell number, acquisition times should be limited to 5 s for PADI, which gives good signal levels; with DESI, the morphological damage was negligible. The operating parameters for the plasma source were optimised, and it was also found that the parameters could be modified to vary the relative intensity of different ions in the mass spectrum.

  6. EVALUATION OF ALTERNATE STAINLESS STEEL SURFACE TREATMENTS FOR MASS SPECTROSCOPY AND OTHER TRITIUM SYSTEMS

    Energy Technology Data Exchange (ETDEWEB)

    Clark, E.; Mauldin, C.; Neikirk, K.

    2012-02-29

    There are specific components in the SRS Tritium Facilities that are required to introduce as few chemical impurities (such as protium and methane) as possible into the process gas. Two such components are the inlet systems for the mass spectroscopy facilities and hydrogen isotope mix standard containers. Two vendors now passivate stainless steel components for these systems, and both are relatively small businesses whose future viability can be questioned, which creates the need for new sources. Stainless steel containers were designed to evaluate alternate surface treatment vendors for tritium storage and handling for these high purity tritium systems. Five vendors applied their own 'best' surface treatments to two containers each - one was a current vendor, another was a chemical vapor deposited silicon coating, and the other three were electropolishing and chemical cleaning vendors. Pure tritium gas was introduced into all ten containers and the composition was monitored over time. The only observed impurities in the gas were some HT, less CT{sub 4}, and very small amounts of T{sub 2}O in all cases. The currently used vendor treated containers contained the least impurities. The chemical vapor deposited silicon treatment resulted in the highest impurity levels. Sampling one set of containers after about one month of tritium exposure revealed the impurity level to be nearly the same as that after more than a year of exposure - this result suggests that cleaning new stainless steel components by tritium gas contact for about a month may be a worthy operation.

  7. Determination of gamithromycin in an injection by ultra-performance liquid chromatography-tandem quadrupole-time-of-flight mass spectrometry.

    Science.gov (United States)

    Wu, Jia-Xin; Zhang, Gang; Song, Min; Liu, Min; Liang, Jing-Le; Xu, Jin-Lei; Shang, Fei; Qi, Peng

    2016-07-07

    In this study, a sensitive and precise method was developed for the determination of gamithromycin in an injection using ultra-performance liquid chromatography-tandem quadrupole-time-of-flight mass spectrometry (UPLC-QTOF-MS) and the results were compared with a similar analysis for the ion fragments of gamithromycin in MS/ MS. The sample was dissolved in methanol then filtered and separated on a C18 column using acetonitrile-0.1% formic acid (containing 2 mmol/L ammonium acetate) as the mobile phase. The flow rate was 0.4 mL/min and the column temperature was 40 °C. The mass spectrometry conditions were electrospray ionization (ESI) operated in positive ion full scan mode and quantified using external calibration. Subsequently, ion fragments of the MS/MS were compared and analyzed. The linear range was 10 ∼ 200 μg/L with a correlation coefficient of 0.9992. The limit of detection (LOD) was 0.77 μg/L and the limit of quantitation (LOQ) was 2.55 μg/L. The average recoveries of the intra-assay were 98.8%-105.6% with a relative standard deviation ranging from 1.79% to 2.38% and the inter-assay were 89.3%-110.7% with a relative standard deviation ranging from 4.93% to 6.27%. After the comparative analysis of the fragments with a Molecular Structure Correlator, the score of the total matching degree reached 83.19 and the scores of each ion fragment matching degree were all greater than 90, which supplied the basis for the confirmation of gamithromycin. The results indicated that the method was simple, sensitive and precise and could be applied in the determination of gamithromycin in real samples.

  8. Solvent system selectivities in countercurrent chromatography using Salicornia gaudichaudiana metabolites as practical example with off-line electrospray mass-spectrometry injection profiling.

    Science.gov (United States)

    Costa, Fernanda das Neves; Jerz, Gerold; Figueiredo, Fabiana de Souza; Winterhalter, Peter; Leitão, Gilda Guimarães

    2015-03-13

    For the development of an efficient two-stage isolation process for high-speed countercurrent chromatography (HSCCC) with focus on principal metabolites from the ethyl acetate extract of the halophyte plant Salicornia gaudichaudiana, separation selectivities of two different biphasic solvent systems with similar polarities were evaluated using the elution and extrusion approach. Efficiency in isolation of target compounds is determined by the solvent system selectivity and their chronological use in multiple separation steps. The system n-hexane-ethyl acetate-methanol-water (0.5:6:0.5:6, v/v/v/v) resulted in a comprehensive separation of polyphenolic glycosides. The system n-hexane-n-butanol-water (1:1:2, v/v/v) was less universal but was highly efficient in the fractionation of positional isomers such as di-substituted cinnamic acid quinic acid derivatives. Multiple metabolite detection performed on recovered HSCCC tube fractions was done with rapid mass-spectrometry profiling by sequential off-line injections to electrospray mass-spectrometry (ESI-MS/MS). Selective ion traces of metabolites delivered reconstituted preparative HSCCC runs. Molecular weight distribution of target compounds in single HSCCC tube fractions and MS/MS fragment data were available. Chromatographic areas with strong co-elution effects and fractions of pure recoverable compounds were visualized. In total 11 metabolites have been identified and monitored. Result of this approach was a fast isolation protocol for S. gaudichaudiana metabolites using two solvent systems in a strategic sequence. The process could easily be scaled-up to larger lab-scale or industrial recovery. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Differentiation of leaf and whole-plant samples of di- and tetraploid Gynostemma pentaphyllum (Thunb.) Makino using flow-injection mass spectrometric(FIMS) fingerprinting method combined with chemometric approaches

    Science.gov (United States)

    In the present study, the feasibility and advantages of employing a flow-injection mass spectrometry (FIMS) fingerprinting method combined with chemometric analyses for assessment of di- and tetraploid leaf and whole-plant Gynostemma. pentaphyllum (Thunb.) Makino samples were investigated for the fi...

  10. Develop of ceramic effects: surface finishes, through digital inject technology; Desarrollo de efectos ceramicos como acabados superficiales, mediante tecnologia de inyeccion digital

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-07-01

    Ferro Spain SA has tackled the practical viability of tile surfaces decoration by means of applying layers of reduced thickness by means of the use of digital injection technology by ink jet and, specifically, relating to effects and superficial finishes different from colouring. It has been studied several mechanisms which allow to get those effects and the influence of the main variables. It has also been assessed the obtained results dealing with the current regulations as in the case of non-slip effect. (Author)

  11. Greenland ice sheet surface mass-balance modeling in a 131-year perspective, 1950-2080

    Energy Technology Data Exchange (ETDEWEB)

    Mernild, Sebastian Haugard [Los Alamos National Laboratory; Liston, Glen [COLORADO STATE UNIV.; Hiemstra, Christopher [COLORADO STATE UNIV.; Christensen, Jens [DANISH METEOROLOGICAL INS.

    2009-01-01

    Fluctuations in the Greenland Ice Sheet (GrIS) surface mass-balance (SMB) and freshwater influx to the surrounding oceans closely follow climate fluctuations and are of considerable importance to the global eustatic sea level rise. SnowModel, a state-of-the-art snow-evolution modeling system, was used to simulate variations in the GrIS melt extent, surface water balance components, changes in SMB, and freshwater influx to the ocean. The simulations are based on the IPCC scenario AlB modeled by the HIRHAM4 RCM (using boundary conditions from ECHAM5 AOGCM) from 1950 through 2080. In-situ meteorological station (GC-Net and WMO DMI) observations from inside and outside the GrIS were used to validate and correct RCM output data before it was used as input for SnowModel. Satellite observations and independent SMB studies were used to validate the SnowModel output and confirm the model's robustness. We simulated a {approx}90% increase in end-of-summer surface melt extent (0.483 x 10{sup 6} km{sup 2}) from 1950 to 2080, and a melt index (above 2,000-m elevation) increase of 138% (1.96 x 10{sup 6} km{sup 2} x days). The greatest difference in melt extent occured in the southern part of the GrIS, and the greatest changes in the number of melt days was seen in the eastern part of the GrIS ({approx}50-70%) and was lowest in the west ({approx}20-30%). The rate of SMB loss, largely tied to changes in ablation processes, lead to an enhanced average loss of 331 km{sup 3} from 1950 to 2080, an average 5MB level of -99 km{sup 3} for the period 2070-2080. GrIS surface freshwater runoff yielded an eustatic rise in sea level from 0.8 {+-} 0.1 (1950-1959) to 1.9 {+-} 0.1 mm (2070-2080) sea level equivalent (SLE) y{sup -1}. The accumulated GrIS freshwater runoff contribution from surface melting equaled 160 mm SLE from 1950 through 2080.

  12. Surface-sampling and analysis of TATP by swabbing and gas chromatography/mass spectrometry.

    Science.gov (United States)

    Romolo, Francesco Saverio; Cassioli, Luigi; Grossi, Silvana; Cinelli, Giuseppe; Russo, Mario Vincenzo

    2013-01-10

    The method of sample recovery for trace detection and identification of explosives plays a critical role in several criminal investigations. After bombing, there can be difficulties in sending big objects to a laboratory for analysis. Traces can also be searched for on large surfaces, on hands of suspects or on surfaces where the explosive was placed during preparatory phases (e.g. places where an IED was assembled, vehicles used for transportation, etc.). In this work, triacetone triperoxide (TATP) was synthesized from commercial precursors following reported methods. Several portions of about 6mg of TATP were then spread on different surfaces (e.g. floors, tables, etc.) or used in handling tests. Three different swabbing systems were used: a commercial swab, pre-wetted with propan-2-ol (isopropanol) and water (7:3), dry paper swabs, and cotton swabs wetted with propan-2-ol. Paper and commercial swabs were also used to sample a metal plate, where a small charge of about 4g of TATP was detonated. Swabs were sealed in small glass jars with screw caps and Parafilm(®) M and sent to the laboratory for analysis. Swabs were extracted and analysed several weeks later by gas chromatography/mass spectrometry. All the three systems gave positive results, but wetted swabs collected higher amounts of TATP. The developed procedure showed its suitability for use in real cases, allowing TATP detection in several simulations, including a situation in which people wash their hands after handling the explosive. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  13. Reduction of aflatoxin B1 during tortilla production and identification of degradation by-products by direct-injection electrospray mass spectrometry

    Directory of Open Access Journals (Sweden)

    Abigail Moreno-Pedraza

    2015-01-01

    Full Text Available Objective. To determine the effect of pH, and exposure time over the inactivation of aflatoxin B1 (AFB1 during the tortilla making process as well as the degradative molecules generated. Materials and methods. Inactivation of AFB1 in maize-dough with alkaline pH and in alkaline methanolic solutions was determined by HPLC. Kinetics of time exposure of AFB1 in methanolic solution and the degradative products were analyzed by direct injection electrospray mass spectometry (DIESI-MS. Results. The alkaline pH of the maize-dough after nixtamalización between 10.2, and 30-40 minutes of resting at room temperature allows the 100% reduction of AFB1. DIESI-MS analysis of the extracts indicated the presence of two degradation molecules from AFB1. Conclusion. The alkaline pH of maize-dough and resting time are the principal factors involved in diminishing AFB1 levels in tortillas. A procedure to the tortilla making process is proposed, which allows the reduction of remnant AFB1, avoiding the accumulative effect over consumers.

  14. Performance of different preconcentration columns used in sequential injection analysis and inductively coupled plasma-mass spectrometry for multielemental determination in seawater

    Science.gov (United States)

    Jiménez, María. S.; Velarte, Rosario; Castillo, Juan R.

    2002-03-01

    A simple, versatile and economical method of sequential injection analysis and inductively coupled plasma-mass spectrometry with matrix removal in two different ion-exchange resins for the determination of Al, As, Co, Cu, Mn, Mo, Ni, Pb and V is reported. The resins used, both of which contain the iminodiacetic acid functional group, were Chelex 100 and Metpac CC-1. With both resins, a matrix removal step (alkaline and alkaline-earth metals) with ammonium acetate is required before elution of the analytes with 2 M HNO 3. The procedure was validated by analyzing CASS-3 seawater reference material and good agreement was found with the certified values. Precision ( n=8) for the nine elements was in the range 0.8-4.9% for the Chelex 100 column and the recoveries ranged from 87.4 to 107.9%, except for Cu (78.7%) and Pb (74.9%), owing to the formation of hydroxides. For the Metpac CC-1 column, precision for the nine elements was in the range 1.2-7.1% and the recoveries between 91.7 and 109.3%, except for Al (127.2%), Co (118.5%) and Ni (127.5%) due to contamination problems.

  15. Flow injection on-line dilution for multi-element determination in human urine with detection by inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald; Gammelgaard, Bente

    2001-01-01

    A simple flow injection on-line dilution procedure with detection by inductively coupled plasma mass spectrometry (ICP-MS) was developed for the determination of copper, zinc, arsenic, lead, selenium, nickel and molybdenum in human urine. Matrix effects were minimized by employing a dilution factor...... of 16.5 with on-line standard addition, and sup/ 103/Rh was used as internal standard to compensate for signal fluctuation. The procedure was validated by the analysis of two standard reference materials SRM 2670 (NIST) and Seronorm(TM) Trace Elements in Urine. Recovery experiments were performed...... by spiking the reference materials as well as artificial urine. The detection limits (mug/l were 0.12, 0.96, 0.30, 0.09, 0.45, 0.08, 0.09, and the precisions (RSD,%) were 2.6, 2.3, 3.0, 3.7, 3.7, 4.9, 2.8 for Cu, Zn, As, Pb, Se, Ni and Mo, respectively. The procedure was applied to the analysis of 41 human...

  16. Direct injection of tissue extracts in liquid chromatography/tandem mass spectrometry for the determination of pharmaceuticals and other contaminants of emerging concern in mollusks.

    Science.gov (United States)

    Bayen, Stéphane; Estrada, Elvagris Segovia; Juhel, Guillaume; Kelly, Barry C

    2015-07-01

    In the present study, a straightforward approach was validated for the analysis of pharmaceutically active compounds and endocrine-disrupting chemicals in the mollusk tissues, with a focus on two species commonly consumed in Southeast Asia (green mussels: Perna viridis; lokan clams: Polymesoda expansa). This approach relied on a simple solvent extraction (shaker table) followed by direct injection in liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). This "cleanup-free" approach was made possible by the use of isotopically labeled surrogates (to correct for matrix effects) and a post-column switch on the LC-MS/MS system (to remove potential interfering material). Altogether, relative recoveries were satisfactory for 36 out of 44 compounds (26-163% range) and excellent for 27 out of 44 compounds (79-107% range). Method detection limits (MDLs) were usually expressed in the nanogram per gram wet weight (ww) range and below. The method was successfully applied to 16 batches of green mussel samples collected in Singapore coastal waters. Trace levels of six compounds were detected in mussel tissues: caffeine (0.22-1.55 ng g(-1) ww), carbamazepine (

  17. Fast Determination of Yttrium and Rare Earth Elements in Seawater by Inductively Coupled Plasma-Mass Spectrometry after Online Flow Injection Pretreatment

    Directory of Open Access Journals (Sweden)

    Zuhao Zhu

    2018-02-01

    Full Text Available A method for daily monitoring of yttrium and rare earth elements (YREEs in seawater using a cheap flow injection system online coupled to inductively coupled plasma-mass spectrometry is reported. Toyopearl AF Chelate 650M® resin permits separation and concentration of YREEs using a simple external calibration. A running cycle consumed 6 mL sample and took 5.3 min, providing a throughput of 11 samples per hour. Linear ranges were up to 200 ng kg−1 except Tm (100 ng kg−1. The precision of the method was <6% (RSDs, n = 5, and recoveries ranged from 93% to 106%. Limits of detection (LODs were in the range 0.002 ng kg−1 (Tm to 0.078 ng kg−1 (Ce. Good agreement between YREEs concentrations in CASS-4 and SLEW-3 obtained in this work and results from other studies was observed. The proposed method was applied to the determination of YREEs in seawater from the Jiulong River Estuary and the Taiwan Strait.

  18. Fast Determination of Yttrium and Rare Earth Elements in Seawater by Inductively Coupled Plasma-Mass Spectrometry after Online Flow Injection Pretreatment.

    Science.gov (United States)

    Zhu, Zuhao; Zheng, Airong

    2018-02-23

    A method for daily monitoring of yttrium and rare earth elements (YREEs) in seawater using a cheap flow injection system online coupled to inductively coupled plasma-mass spectrometry is reported. Toyopearl AF Chelate 650M ® resin permits separation and concentration of YREEs using a simple external calibration. A running cycle consumed 6 mL sample and took 5.3 min, providing a throughput of 11 samples per hour. Linear ranges were up to 200 ng kg -1 except Tm (100 ng kg -1 ). The precision of the method was <6% (RSDs, n = 5), and recoveries ranged from 93% to 106%. Limits of detection (LODs) were in the range 0.002 ng kg -1 (Tm) to 0.078 ng kg -1 (Ce). Good agreement between YREEs concentrations in CASS-4 and SLEW-3 obtained in this work and results from other studies was observed. The proposed method was applied to the determination of YREEs in seawater from the Jiulong River Estuary and the Taiwan Strait.

  19. Fluoroscopically guided transforaminal epidural steroid injections at a quaternary-care teaching institution: effect of trainee involvement and patient body mass index on fluoroscopy time and patient dose.

    Science.gov (United States)

    Tiegs-Heiden, C A; Murthy, N S; Geske, J R; Diehn, F E; Schueler, B A; Wald, J T; Kaufmann, T J; Lehman, V T; Carr, C M; Amrami, K K; Morris, J M; Thielen, K R; Maus, T P

    2016-01-01

    To investigate whether there are differences in fluoroscopy time and patient dose for fluoroscopically guided lumbar transforaminal epidural steroid injections (TFESIs) performed by staff radiologists versus with trainees and to evaluate the effect of patient body mass index (BMI) on fluoroscopy time and patient dose, including their interactions with other variables. Single-level lumbar TFESIs (n=1844) between 1 January 2011 and 31 December 2013 were reviewed. Fluoroscopy time, reference point air kerma (Ka,r), and kerma area product (KAP) were recorded. BMI and trainee involvement were examined as predictors of fluoroscopy time, Ka,r, and KAP in models adjusted for age and gender in multivariable linear models. Stratified models of BMI groups by trainee presence were performed. Increased age was the only significant predictor of increased fluoroscopy time (pfluoroscopy time predicted increased Ka,r and KAP in all groups (pfluoroscopy time or Ka,r in any BMI category. KAP was lower with trainees in the overweight group (p=0.0009) and higher in male patients for all BMI categories (pfluoroscopy time or patient dose. BMI did not affect fluoroscopy time; however, overweight and obese patients received significantly higher Ka,r and KAP. Male patients received a higher KAP in all BMI categories. Limiting fluoroscopy time and good collimation practices should be reinforced in these patients. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  20. Development of a bar adsorptive micro-extraction-large-volume injection-gas chromatography-mass spectrometric method for pharmaceuticals and personal care products in environmental water matrices.

    Science.gov (United States)

    Neng, N R; Nogueira, J M F

    2012-01-01

    The combination of bar adsorptive micro-extraction using activated carbon (AC) and polystyrene-divinylbenzene copolymer (PS-DVB) sorbent phases, followed by liquid desorption and large-volume injection gas chromatography coupled to mass spectrometry, under selected ion monitoring mode acquisition, was developed for the first time to monitor pharmaceutical and personal care products (PPCPs) in environmental water matrices. Assays performed on 25 mL water samples spiked (100 ng L(-1)) with caffeine, gemfibrozil, triclosan, propranolol, carbamazepine and diazepam, selected as model compounds, yielded recoveries ranging from 74% to 99% under optimised experimental conditions (equilibrium time, 16 h (1,000 rpm); matrix characteristics: pH 5, 5% NaCl for AC phase; LD: methanol/acetonitrile (1:1), 45 min). The analytical performance showed good precision (RSD 0.99), where the PS-DVB sorbent phase showed a much better efficiency. By using the standard addition methodology, the application of the present analytical approach on tap, ground, sea, estuary and wastewater samples allowed very good performance at the trace level. The proposed method proved to be a suitable sorption-based micro-extraction alternative for the analysis of priority pollutants with medium-polar to polar characteristics, showing to be easy to implement, reliable, sensitive and requiring a low sample volume to monitor PPCPs in water matrices.

  1. Flow injection on-line dilution for multi-element determination in human urine with detection by inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Wang, J.H.; Hansen, E.H.; Gammelgaard, Bente

    2001-01-01

    A simple flow injection on-line dilution procedure with detection by inductively coupled plasma mass spectrometry (ICP-MS) was developed for the determination of copper, zinc, arsenic, lead, selenium, nickel and molybdenum in human urine. Matrix effects were minimized by employing a dilution fact...... of 16.5 with on-line standard addition, and Rh-103 was used as internal standard to compensate for signal fluctuation. The procedure was validated by the analysis of two standard reference materials SRM 2670 (NIST) and Seronorm (TM) Trace Elements in Urine. Recovery experiments were pet......-formed by spiking the reference materials as well as artificial urine. The detection limits (mug l(-1)) were 0.12, 0.96, 0.30, 0.09, 0.45, 0.08, 0.09, and the precisions (RSD,%) were 2.6, 2.3, 3.0, 3.7, 3.7, 4.9, 2.8 for Cu, Zn, As, Pb, Se, Ni and Mo, respectively. The procedure was applied to the analysis of 41...... human urine samples. No correlations between the concentrations of the elements were observed. (C) 2001 Elsevier Science B.V. All rights reserved...

  2. Trace analysis of pesticides in paddy field water by direct injection using liquid chromatography-quadrupole-linear ion trap-mass spectrometry.

    Science.gov (United States)

    Pareja, Lucía; Martínez-Bueno, M J; Cesio, Verónica; Heinzen, Horacio; Fernández-Alba, A R

    2011-07-29

    A multiresidue method was developed for the quantification and confirmation of 70 pesticides in paddy field water. After its filtration, water was injected directly in a liquid chromatograph coupled to a hybrid triple quadrupole-linear ion trap-mass spectrometer (QqLIT). The list of target analytes included organophosphates, phenylureas, sulfonylureas, carbamates, conazoles, imidazolinones and others compounds widely used in different countries where rice is cropped. Detection and quantification limits achieved were in the range from 0.4 to 80 ng L(-1) and from 2 to 150 ng L(-1), respectively. Correlation coefficients for the calibration curves in the range 0.1-50 μg L(-1) were higher than 0.99 except for diazinon (0.1-25 μg L(-1)). Only 9 pesticides presented more than 20% of signal suppression/enhancement, no matrix effect was observed in the studied conditions for the rest of the target pesticides. The method developed was used to investigate the occurrence of pesticides in 59 water samples collected in paddy fields located in Spain and Uruguay. The study shows the presence of bensulfuron methyl, tricyclazole, carbendazim, imidacloprid, tebuconazole and quinclorac in a concentration range from 0.08 to 7.20 μg L(-1). Copyright © 2011 Elsevier B.V. All rights reserved.

  3. High-spatial and high-mass resolution imaging of surface metabolites of Arabidopsis thaliana by laser desorption-ionization mass spectrometry using colloidal silver.

    Science.gov (United States)

    Jun, Ji Hyun; Song, Zhihong; Liu, Zhenjiu; Nikolau, Basil J; Yeung, Edward S; Lee, Young Jin

    2010-04-15

    High-spatial resolution and high-mass resolution techniques are developed and adopted for the mass spectrometric imaging of epicuticular lipids on the surface of Arabidopsis thaliana. Single cell level spatial resolution of approximately 12 mum was achieved by reducing the laser beam size by using an optical fiber with 25 mum core diameter in a vacuum matrix-assisted laser desorption ionization-linear ion trap (vMALDI-LTQ) mass spectrometer and improved matrix application using an oscillating capillary nebulizer. Fine chemical images of a whole flower were visualized in this high spatial resolution showing substructure of an anther and single pollen grains at the stigma and anthers. The LTQ-Orbitrap with a MALDI ion source was adopted to achieve MS imaging in high mass resolution. Specifically, isobaric silver ion adducts of C29 alkane (m/z 515.3741) and C28 aldehyde (m/z 515.3377), indistinguishable in low-resolution LTQ, can now be clearly distinguished and their chemical images could be separately constructed. In the application to roots, the high spatial resolution allowed molecular MS imaging of secondary roots and the high mass resolution allowed direct identification of lipid metabolites on root surfaces.

  4. High-Spatial and High-Mass Resolution Imaging of Surface Metabolites of Arabidopsis thaliana by Laser Desorption-Ionization Mass Spectrometry Using Colloidal Silver

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Ji Hyun; Song, Zhihong; Liu, Zhenjiu; Nikolau, Basil J.; Yeung, Edward S.; and Lee, Young Jin

    2010-03-17

    High-spatial resolution and high-mass resolution techniques are developed and adopted for the mass spectrometric imaging of epicuticular lipids on the surface of Arabidopsis thaliana. Single cell level spatial resolution of {approx}12 {micro}m was achieved by reducing the laser beam size by using an optical fiber with 25 {micro}m core diameter in a vacuum matrix-assisted laser desorption ionization-linear ion trap (vMALDI-LTQ) mass spectrometer and improved matrix application using an oscillating capillary nebulizer. Fine chemical images of a whole flower were visualized in this high spatial resolution showing substructure of an anther and single pollen grains at the stigma and anthers. The LTQ-Orbitrap with a MALDI ion source was adopted to achieve MS imaging in high mass resolution. Specifically, isobaric silver ion adducts of C29 alkane (m/z 515.3741) and C28 aldehyde (m/z 515.3377), indistinguishable in low-resolution LTQ, can now be clearly distinguished and their chemical images could be separately constructed. In the application to roots, the high spatial resolution allowed molecular MS imaging of secondary roots and the high mass resolution allowed direct identification of lipid metabolites on root surfaces.

  5. Effects of moulding and environmental conditions on the mechanical and surface properties of injection moulded santoprene rubber

    DEFF Research Database (Denmark)

    Islam, Aminul; Ruby, Tobias M.; Jessen, Rikke L.

    the electronics inside from environmental hazards. The sealing ring is injection moulded in Santoprene-a thermoplastic vulcanizate consisting of Polypropelene and highly vulcanized EPDM rubber. The scope of the project was therefore to investigate the properties of Santoprene and make an immediate evaluation...... of whether Santoprene is appropriate for use under the conditions, to which it will be subjected being part of a hearing aid used on daily basis. The conditions tested are: sweat, acid corrosion, extreme temperatures. An evaluation of the maximum load before breakage in relation to manufacturing conditions...

  6. Preparative mass-spectrometry profiling of bioactive metabolites in Saudi-Arabian propolis fractionated by high-speed countercurrent chromatography and off-line atmospheric pressure chemical ionization mass-spectrometry injection.

    Science.gov (United States)

    Jerz, Gerold; Elnakady, Yasser A; Braun, André; Jäckel, Kristin; Sasse, Florenz; Al Ghamdi, Ahmad A; Omar, Mohamed O M; Winterhalter, Peter

    2014-06-20

    Propolis is a glue material collected by honeybees which is used to seal cracks in beehives and to protect the bee population from infections. Propolis resins have a long history in medicinal use as a natural remedy. The multiple biological properties are related to variations in their chemical compositions. Geographical settings and availability of plant sources are important factors for the occurrence of specific natural products in propolis. A propolis ethylacetate extract (800mg) from Saudi Arabia (Al-Baha region) was separated by preparative scale high-speed countercurrent chromatography (HSCCC) using a non-aqueous solvent system n-hexane-ACN (1:1, v/v). For multiple metabolite detection, the resulting HSCCC-fractions were sequentially injected off-line into an atmospheric pressure chemical ionization mass-spectrometry (APCI-MS/MS) device, and a reconstituted mass spectrometry profile of the preparative run was visualized by selected ion traces. Best ion-intensities for detected compounds were obtained in the negative APCI mode and monitored occurring co-elution effects. HSCCC and successive purification steps resulted in the isolation and characterization of various bioactive natural products such as (12E)- and (12Z)-communic acid, sandaracopimaric acid, (+)-ferruginol, (+)-totarol, and 3β-acetoxy-19(29)-taraxasten-20a-ol using EI-, APCI-MS and 1D/2D-NMR. Cycloartenol-derivatives and triterpene acetates were isolated in mixtures and elucidated by EI-MS and 1D-NMR. Free fatty acids, and two labdane fatty acid esters were identified by APCI-MS/MS. In total 19 metabolites have been identified. The novel combination of HSCCC fractionation, and APCI-MS-target-guided molecular mass profiling improve efficiency of lead-structure identification. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Influence of the surface permeability on the GRACE water mass variations. Case of the Lake Chad basin.

    Science.gov (United States)

    Lopez, T.; Ramillien, G.; Antoine, R.; Darrozes, J.; Rabinowicz, M.

    2017-12-01

    Since its launch in 2002, the Gravity Recovery And Climate Experiment (GRACE) has been measured the tiny variations of the gravity field due to redistributions of water mass in the surface envelops of Earth. At a spatial resolution of 400 km, these satellite data offer a unique perspective to understand the evolution of continental water storage at regional and global scales, and therefore they enable the monitoring of the hydrological systems such as river basins. It is well known that seasonal cycle, droughts, vegetation and human extractions are the main contributors of the hydrology signals sensed by GRACE. However, the coupling between land surface and the atmosphere is important in semi-arid and arid regions, in particular in West Africa [1]. We propose to quantify the surface water fluxes in the Lake Chad region by using the 10-day water mass solutions of the GRACE mission in the context of the regular West African monsoon. Alternation of the evaporation/condensation cycles during the recent period are interpreted in terms of surface vertical permeability changes that control the thermal evolution in this region [2]. GRACE solutions reveal an interannual increase of surface water mass at the beginning of the dry seasons, especially between 2005 and 2008. We propose that this gain of surface water mass is caused by a seasonal cycle of clay fracturing that controls the evaporation/condensation cycle. [1] Koster et al. (2004). Science, 305, 1138-1140. [2] Lopez et al. (2016). Surv. Geophys., 37 (2), 471-502.

  8. Surface analytical investigation of diamond coatings and nucleation processes by secondary ion mass spectrometry

    International Nuclear Information System (INIS)

    Steiner, R.

    1993-10-01

    Imaging SIMS for the investigation of substrate surfaces: the influence of the substrate surface on diamond nucleation is a major topic in the investigation of the chemical vapour deposition (CVD) of diamond. It is well known that the nucleation density can be enhanced by scratching the substrate surface with abrasive powders. Diamond can nucleate at scratches or at residues of the polishing material. In the present work the surface of refractory metals (Mo, Nb, Ta, W) polished with silicon carbide and diamond powder is studied by imaging (2- or 3-D) secondary ion mass spectrometry (SIMS). In first experiments the distribution of SiC and/or diamond residues after polishing was determined. The reaction of diamond with the substrate during heating to deposition temperatures was investigated. Investigation of WC/Co hardmetal substrates: it is well known that Co contained in the binder phase of the hard metal inhibits a strong adhesion between the diamond film and the substrate, which is need for an application as cutting tool. Several attempts to improve the adhesion have been reported up to now. In this work a pre-treatment procedure leading to the formation of Co compounds (borides and silicides) which are stable under diamond deposition conditions were investigated. Furthermore, the application of intermediate sputter layers consisting of chromium and titanium were studied. Investigation of P-doped diamond coatings: in the quaternary phase diagram C-P-B-N exist some phases with diamond structure and superhard phases (e.g BP, c-BN). Also a hypothetical superhard phase of the composition C 3 N 4 is predicted. A scientific objective is the synthesis of such phases by chemical vapour deposition. An increase of the phosphorus concentration effects a distinct change in the morphology of the deposited coatings. A major advantage of SIMS is that the concentration profiles can be measured through the whole film, due to the sputter removal of the sample, and the interface

  9. Numerical study for nanofluid flow due to a nonlinear curved stretching surface with convective heat and mass conditions

    Directory of Open Access Journals (Sweden)

    Tasawar Hayat

    Full Text Available This article presents the simultaneous effects of convective heat and mass conditions in boundary-layer flow of nanoliquid due to a nonlinear curved stretching surface. A nonlinear curved stretching surface is used to generate the flow. Thermophoretic diffusion and random motion features are also incorporated. Convective heat and mass conditions are imposed at boundary. Suitable variables are utilized to convert the nonlinear partial differential system into nonlinear ordinary differential system. The obtained nonlinear systems are solved numerically through shooting technique. Plots are displayed in order to explore the role of physical flow variables on the solutions. The skin-friction coefficient and local Nusselt and Sherwood numbers are computed and examined. Our findings indicate that the local Nusselt and Sherwood numbers are reduced for larger values of thermophoresis parameter. Keywords: Nonlinear curved stretching surface, Nanoparticles, Convective heat and mass conditions, Numerical solution

  10. Ecology of ontogenetic body-mass scaling of gill surface area in a freshwater crustacean.

    Science.gov (United States)

    Glazier, Douglas S; Paul, David A

    2017-06-01

    Several studies have documented ecological effects on intraspecific and interspecific body-size scaling of metabolic rate. However, little is known about how various ecological factors may affect the scaling of respiratory structures supporting oxygen uptake for metabolism. To our knowledge, our study is the first to provide evidence for ecological effects on the scaling of a respiratory structure among conspecific populations of any animal. We compared the body-mass scaling of gill surface area (SA) among eight spring-dwelling populations of the amphipod crustacean Gammarus minus Although gill SA scaling was not related to water temperature, conductivity or G. minus population density, it was significantly related to predation regime (and secondarily to pH). Body-mass scaling slopes for gill SA were significantly lower in four populations inhabiting springs with fish predators than for four populations in springs without fish (based on comparing means of the population slopes, or slopes calculated from pooled raw data for each comparison group). As a result, gill SA was proportionately smaller in adult amphipods from springs with versus without fish. This scaling difference paralleled similar differences in the scaling exponents for the rates of growth and resting metabolic rate. We hypothesized that gill SA scaling is shallower in fish-containing versus fishless spring populations of G. minus because of effects of size-selective predation on size-specific growth and activity that in turn affect the scaling of oxygen demand and concomitantly the gill capacity (SA) for oxygen uptake. Although influential theory claims that metabolic scaling is constrained by internal body design, our study builds on previous work to show that the scaling of both metabolism and the respiratory structures supporting it may be ecologically sensitive and evolutionarily malleable. © 2017. Published by The Company of Biologists Ltd.

  11. The effect of insulated combustion chamber surfaces on direct-injected diesel engine performance, emissions, and combustion

    Science.gov (United States)

    Dickey, Daniel W.; Vinyard, Shannon; Keribar, Rifat

    1988-01-01

    The combustion chamber of a single-cylinder, direct-injected diesel engine was insulated with ceramic coatings to determine the effect of low heat rejection (LHR) operation on engine performance, emissions, and combustion. In comparison to the baseline cooled engine, the LHR engine had lower thermal efficiency, with higher smoke, particulate, and full load carbon monoxide emissions. The unburned hydrocarbon emissions were reduced across the load range. The nitrous oxide emissions increased at some part-load conditions and were reduced slightly at full loads. The poor LHR engine performance was attributed to degraded combustion characterized by less premixed burning, lower heat release rates, and longer combustion duration compared to the baseline cooled engine.

  12. Glacier surface mass balance and freshwater runoff modeling for the entire Andes Cordillera

    Science.gov (United States)

    Mernild, Sebastian H.; Liston, Glen E.; Yde, Jacob C.

    2017-04-01

    Glacier surface mass balance (SMB) observations for the Andes Cordillera are limited and, therefore, estimates of the SMB contribution from South America to sea-level rise are highly uncertain. Here, we simulate meteorological, snow, glacier surface, and hydrological runoff conditions and trends for the Andes Cordillera (1979/80-2013/14), covering the tropical latitudes in the north down to the sub-polar latitudes in the far south, including the Northern Patagonia Ice Field (NPI) and Southern Patagonia Ice Field (SPI). SnowModel - a fully integrated energy balance, blowing-snow distribution, multi-layer snowpack, and runoff routing model - was used to simulate glacier SMBs for the Andes Cordillera. The Randolph Glacier Inventory and NASA Modern-Era Retrospective Analysis for Research and Applications products, downscaled in SnowModel, allowed us to conduct relatively high-resolution simulations. The simulated glacier SMBs were verified against independent directly-observed and satellite gravimetry and altimetry-derived SMB, indicating a good statistical agreement. For glaciers in the Andes Cordillera, the 35-year mean annual SMB was found to be -1.13 m water equivalent. For both NPI and SPI, the mean SMB was positive (where calving is the likely reason for explaining why geodetic estimates are negative). Further, the spatio-temporal freshwater river runoff patterns from individual basins, including their runoff magnitude and change, were simulated. For the Andes Cordillera rivers draining to the Pacific Ocean, 86% of the simulated runoff originated from rain, 12% from snowmelt, and 2% from ice melt, whereas, for example, for Chile, the water-source distribution was 69, 24, and 7%, respectively. Along the Andes Cordillera, the 35-year mean basin outlet-specific runoff (L s-1 km-2) showed a characteristic regional hourglass shape pattern with highest runoff in both Colombia and Ecuador and in Patagonia, and lowest runoff in the Atacama Desert area.

  13. Cefoxitin Injection

    Science.gov (United States)

    ... injection is used to treat infections caused by bacteria including pneumonia and other lower respiratory tract (lung) infections; and urinary tract, abdominal (stomach area), female reproductive organs, blood, ... by killing bacteria.Antibiotics such as cefoxitin injection will not work ...

  14. Golimumab Injection

    Science.gov (United States)

    ... damaged, and do not use an auto-injection device if the security seal is broken. Look through the viewing window on the prefilled syringe or auto-injection device. The liquid inside should be clear and colorless ...

  15. Doxycycline Injection

    Science.gov (United States)

    ... may have been exposed to anthrax in the air. Doxycycline injection is in a class of medications ... decrease the effectiveness of hormonal contraceptives (birth control pills, patches, rings, or injections). Talk to your doctor ...

  16. Abaloparatide Injection

    Science.gov (United States)

    ... injection may cause osteosarcoma (bone cancer) in laboratory rats. It is not known whether abaloparatide injection increases ... too have too much calcium in the blood, hyperparathyroidism (condition in which the body produces too much ...

  17. Paliperidone Injection

    Science.gov (United States)

    Paliperidone extended-release injections (Invega Sustenna, Invega Trinza) are used to treat schizophrenia (a mental illness that ... interest in life, and strong or inappropriate emotions). Paliperidone extended-release injection (Invega Sustenna) is also used ...

  18. Doripenem Injection

    Science.gov (United States)

    ... injection is in a class of medications called carbapenem antibiotics. It works by killing bacteria.Antibiotics such ... if you are allergic to doripenem injection; other carbapenem antibiotics such as imipenem/cilastatin (Primaxin) or meropenem ( ...

  19. Ceftriaxone Injection

    Science.gov (United States)

    Ceftriaxone injection is used to treat certain infections caused by bacteria such as gonorrhea (a sexually transmitted ... skin, urinary tract, blood, bones, joints, and abdomen. Ceftriaxone injection is also sometimes given before certain types ...

  20. Nalbuphine Injection

    Science.gov (United States)

    ... injection is in a class of medications called opioid agonist-antagonists. It works by changing the way ... suddenly stop using nalbuphine injection, you may experience withdrawal symptoms including restlessness; teary eyes; runny nose; yawning; ...

  1. Naltrexone Injection

    Science.gov (United States)

    ... Videos & Tools Español You Are Here: Home → Drugs, Herbs and Supplements → Naltrexone Injection URL of this page: ... become depressed and sometimes try to harm or kill themselves. Receiving naltrexone injection does not decrease the ...

  2. Power System Mass Analysis for Hydrogen Reduction Oxygen Production on the Lunar Surface

    Science.gov (United States)

    Colozza, Anthony J.

    2009-01-01

    The production of oxygen from the lunar regolith requires both thermal and electrical power in roughly similar proportions. This unique power requirement is unlike most applications on the lunar surface. To efficiently meet these requirements, both solar PV array and solar concentrator systems were evaluated. The mass of various types of photovoltaic and concentrator based systems were calculated to determine the type of power system that provided the highest specific power. These were compared over a range of oxygen production rates. Also a hybrid type power system was also considered. This system utilized a photovoltaic array to produce the electrical power and a concentrator to provide the thermal power. For a single source system the three systems with the highest specific power were a flexible concentrator/Stirling engine system, a rigid concentrator/Stirling engine system and a tracking triple junction solar array system. These systems had specific power values of 43, 34, and 33 W/kg, respectively. The hybrid power system provided much higher specific power values then the single source systems. The best hybrid combinations were the triple junction solar array with the flexible concentrator and the rigid concentrator. These systems had a specific power of 81 and 68 W/kg, respectively.

  3. Heat and mass transfer boundary conditions at the surface of a heated sessile droplet

    Science.gov (United States)

    Ljung, Anna-Lena; Lundström, T. Staffan

    2017-12-01

    This work numerically investigates how the boundary conditions of a heated sessile water droplet should be defined in order to include effects of both ambient and internal flow. Significance of water vapor, Marangoni convection, separate simulations of the external and internal flow, and influence of contact angle throughout drying is studied. The quasi-steady simulations are carried out with Computational Fluid Dynamics and conduction, natural convection and Marangoni convection are accounted for inside the droplet. For the studied conditions, a noticeable effect of buoyancy due to evaporation is observed. Hence, the inclusion of moisture increases the maximum velocities in the external flow. Marangoni convection will, in its turn, increase the velocity within the droplet with up to three orders of magnitude. Results furthermore show that the internal and ambient flow can be simulated separately for the conditions studied, and the accuracy is improved if the internal temperature gradient is low, e.g. if Marangoni convection is present. Simultaneous simulations of the domains are however preferred at high plate temperatures if both internal and external flows are dominated by buoyancy and natural convection. The importance of a spatially resolved heat and mass transfer boundary condition is, in its turn, increased if the internal velocity is small or if there is a large variation of the transfer coefficients at the surface. Finally, the results indicate that when the internal convective heat transport is small, a rather constant evaporation rate may be obtained throughout the drying at certain conditions.

  4. Mass transfer behavior of tritium from air to water through the water surface

    International Nuclear Information System (INIS)

    Takata, Hiroki; Nishikawa, Masabumi; Kamimae, Kozo

    2005-01-01

    It is anticipated that a certain amount of tritiated water exists in the atmosphere of tritium handling facilities, and it is recognized that the hazardous potential of tritiated water is rather high. Then, it is important to grasp the behavior of tritiated water for preserving of the radiation safety. The mass transfer behavior of tritium from air to water through the water surface was discussed in this study. The evaporation rate of water and the condensation rate of water were experimentally examined from measurement of change of the weight of distilled water. The tritium transfer rate from the tritiated water in air to the distilled water was also experimentally examined by using a liquid scintillation counter. Experimental results about change of tritium level in a small beaker placed in the atmosphere with tritiated water showed that diffusion of tritium in water and gas flow in the atmosphere gives considerable effect on tritium transfer. The estimation method of the tritium transfer made in this study was applied to explain the data at The Japan Atomic Power Company second power station at Tsuruga and good agreement was obtained. (author)

  5. Quantification of four artificial sweeteners in Finnish surface waters with isotope-dilution mass spectrometry

    International Nuclear Information System (INIS)

    Perkola, Noora; Sainio, Pirjo

    2014-01-01

    The artificial sweeteners sucralose (SCL), acesulfame (ACS), saccharin (SAC), and cyclamate (CYC) have been detected in environmental waters in Europe and North America. Higher environmental levels are expected in view of the increasing consumption of these food additives. In this study, an isotope-dilution mass spectrometry (IDMS) LC–MS/MS method was developed and validated for quantifying the four artificial sweeteners in boreal lakes (n = 3) and rivers (n = 12). The highest concentrations of ACS, SAC, CYC and SCL were 9,600, 490, 210 and 1000 ng/L, respectively. ACS and SAC were detected in all studied samples, and CYC and SCL in 98% and 56% of the samples. Seasonal trends of ACS and SAC were observed in some rivers. ACS and SCL concentrations in rivers correlated linearly with population equivalents of the wastewater treatment plants in the catchment areas, whereas SAC and CYC concentrations depend more on the source. -- Highlights: • A reliable method for analysing artificial sweeteners in water was validated. • Artificial sweeteners were quantified in boreal rivers and lakes. • Most concentrations were in accordance with previous European studies. • Acesulfame and saccharine concentrations were high in the most contaminated rivers. • Correlation observed between concentrations and mean water throughflow in rivers. -- High concentrations of artificial sweeteners were obtained, which indicates slow or negligible degradation of these compounds in boreal surface waters

  6. Simplifying and expanding analytical capabilities for various classes of doping agents by means of direct urine injection high performance liquid chromatography high resolution/high accuracy mass spectrometry.

    Science.gov (United States)

    Görgens, Christian; Guddat, Sven; Thomas, Andreas; Wachsmuth, Philipp; Orlovius, Anne-Katrin; Sigmund, Gerd; Thevis, Mario; Schänzer, Wilhelm

    2016-11-30

    So far, in sports drug testing compounds of different classes are processed and measured using different screening procedures. The constantly increasing number of samples in doping analysis, as well as the large number of substances with doping related, pharmacological effects require the development of even more powerful assays than those already employed in sports drug testing, indispensably with reduced sample preparation procedures. The analysis of native urine samples after direct injection provides a promising analytical approach, which thereby possesses a broad applicability to many different compounds and their metabolites, without a time-consuming sample preparation. In this study, a novel multi-target approach based on liquid chromatography and high resolution/high accuracy mass spectrometry is presented to screen for more than 200 analytes of various classes of doping agents far below the required detection limits in sports drug testing. Here, classic groups of drugs as diuretics, stimulants, β 2 -agonists, narcotics and anabolic androgenic steroids as well as various newer target compounds like hypoxia-inducible factor (HIF) stabilizers, selective androgen receptor modulators (SARMs), selective estrogen receptor modulators (SERMs), plasma volume expanders and other doping related compounds, listed in the 2016 WADA prohibited list were implemented. As a main achievement, growth hormone releasing peptides could be implemented, which chemically belong to the group of small peptides (0.99), limit of detection (0.1-25ng/mL; 3'OH-stanozolol glucuronide: 50pg/mL; dextran/HES: 10μg/mL) and matrix effects. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Longitudinal growth of French singleton children born after in vitro fertilization and intracytoplasmic sperm injection. Body mass index up to 5 years of age.

    Science.gov (United States)

    Meddeb, L; Pauly, V; Boyer, P; Montjean, D; Devictor, B; Curel, L; Seng, P; Sambuc, R; Gervoise Boyer, M

    2017-06-01

    The literature presents conflicting results on the epigenetic effect of in vitro fertilization (IVF) on the short-term and mid-term growth of children. These contradictory results may be related to the use of heterogeneous methodologies and non-longitudinal data. The goal of this study was to compare the body mass index (BMI) of children conceived via IVF and spontaneous conception (SC) children, using longitudinal data from birth to 5 years. This study compared 118 singleton children born after in vitro fertilization, with or without intracytoplasmic sperm injection (ICSI), selected from a pre-existing single-center cohort to 320 SC children from the same geographic area. BMI and its evolution were analyzed using the mixed-effect model during three periods: before standing acquisition (from birth to 1 year of age), during standing acquisition, and the following period from 2 to 5 years of age. BMI means were not significantly different between groups regardless of the period, when adjusting for confounding factors related to parents, pregnancy, and children's characteristics and lifestyle. Nevertheless, during the standing acquisition period, children born after IVF-ICSI presented a less significant decrease in BMI (P<0.05). In addition, for each period we identified influencing factors (maternal BMI, level of wealth indicator) associated with BMI. In the study population, the suspected epigenetic influence of IVF reported in the literature was not observed for BMI from birth to 5 years of age. Further investigations need to be conducted to determine if the suspected influence of IVF on adiposity could be expressed through other parameters. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  8. Effects of aromatics, olefins and distillation temperatures (T50 & T90) on particle mass and number emissions from gasoline direct injection (GDI) vehicles

    International Nuclear Information System (INIS)

    Zhu, Rencheng; Hu, Jingnan; Bao, Xiaofeng; He, Liqiang; Zu, Lei

    2017-01-01

    Abstratct: Fuel quality is among the primary reasons for severe vehicle pollution. A limited understanding of the effects of gasoline properties on modern vehicle emissions is one obstacle for the establishment of stricter fuel standards in China. The goal of this study was to evaluate the effects of aromatic and olefin contents and T50 and T90 (defined as the 50%v and 90%v distillation temperatures) on tailpipe emissions from gasoline direct injection (GDI) vehicles compliant with China 4 standards. Both gaseous and particle emissions using different types of gasoline were measured. Changing aromatic and olefin contents had relatively small impacts on fuel consumption. Compared with olefins and T90, the regulated gaseous emissions were impacted more by aromatics and T50. Evident decreases of the particle mass (PM) and particle number (PN) emissions were noticed when the aromatic content and T90 decreased. Reducing the olefin content slightly decreased the PM emissions and increased the PN emissions. With decreasing T50, the PM emissions increased and the PN emissions slightly decreased. These results suggest that aromatic content and T90 should be decreased to reduce particle emissions from GDI vehicles. The information presented in this study provides some suggestions for how to improve gasoline quality in China. - Highlights: • Effect of aromatics, olefins, T50 and T90 on GDI vehicle emissions was investigated. • Aromatics and olefins had little impact on fuel consumption and CO 2 emissions. • Reducing the aromatic content and T90 significantly decreased PM and PN emissions. • Changing the olefin content and T50 had a minor impact on particle emissions. • Thresholds of aromatics and T90 should be tightened in future gasoline regulations.

  9. The determination of acrylamide in environmental and drinking waters by large-volume injection - hydrophilic-interaction liquid chromatography and tandem mass spectrometry.

    Science.gov (United States)

    Backe, Will J; Yingling, Virginia; Johnson, Todd

    2014-03-21

    A simple and sensitive analytical method was developed to quantify levels of acrylamide in environmental and drinking waters. The analytical method consisted of solvent exchanging acrylamide from 2mL of water into 2mL of dichloromethane using acetonitrile as an intermediate. The sample was then directly analyzed by large-volume (750μL) injection - hydrophilic-interaction liquid chromatography and tandem mass spectrometry. The method detection limit and reporting level were 2.4ng/L and 17ng/L of acrylamide, respectively. The recovery of acrylamide during solvent exchange was 95±2.8% and the matrix effects were 12±2.2% in river water. The use of atmospheric-pressure chemical ionization reduced matrix effects; however, it also reduced method sensitivity by a factor of 2.2 compared to electrospray ionization. Matrix effects were compensated for by the use of an isotopically-labeled internal standard and the method accuracy was 89±3.0% at 25ng/L of acrylamide and 102±2.6% at 250ng/L of acrylamide. The precision of the method was less than 6% relative standard deviation at both 25ng/L and 250ng/L of acrylamide. Samples from a sand-and-gravel mine and a drinking-water treatment plant were acquired to demonstrate the method. The concentrations of acrylamide at the sand-and-gravel mine were up to 280ng/L. In the drinking-water treatment plant, the concentration of acrylamide was approximately double in the finished drinking water when compared to other stages in the drinking-water treatment process. Disinfection or fluoridation may result in higher concentrations of acrylamide in finished drinking water; however, further research in this area is necessary. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Fluoroscopically guided transforaminal epidural steroid injections at a quaternary-care teaching institution: effect of trainee involvement and patient body mass index on fluoroscopy time and patient dose

    International Nuclear Information System (INIS)

    Tiegs-Heiden, C.A.; Murthy, N.S.; Geske, J.R.; Diehn, F.E.; Schueler, B.A.; Wald, J.T.; Kaufmann, T.J.; Lehman, V.T.; Carr, C.M.; Amrami, K.K.; Morris, J.M.; Thielen, K.R.; Maus, T.P.

    2016-01-01

    Aim: To investigate whether there are differences in fluoroscopy time and patient dose for fluoroscopically guided lumbar transforaminal epidural steroid injections (TFESIs) performed by staff radiologists versus with trainees and to evaluate the effect of patient body mass index (BMI) on fluoroscopy time and patient dose, including their interactions with other variables. Materials and methods: Single-level lumbar TFESIs (n=1844) between 1 January 2011 and 31 December 2013 were reviewed. Fluoroscopy time, reference point air kerma (K a,r ), and kerma area product (KAP) were recorded. BMI and trainee involvement were examined as predictors of fluoroscopy time, K a,r , and KAP in models adjusted for age and gender in multivariable linear models. Stratified models of BMI groups by trainee presence were performed. Results: Increased age was the only significant predictor of increased fluoroscopy time (p<0.0001). K a,r and KAP were significantly higher in patients with a higher BMI (p<0.0001 and p=0.0009). When stratified by BMI, longer fluoroscopy time predicted increased K a,r and KAP in all groups (p<0.0001). Trainee involvement was not a statistically significant predictor of fluoroscopy time or K a,r in any BMI category. KAP was lower with trainees in the overweight group (p=0.0009) and higher in male patients for all BMI categories (p<0.02). Conclusion: Trainee involvement did not result in increased fluoroscopy time or patient dose. BMI did not affect fluoroscopy time; however, overweight and obese patients received significantly higher K a,r and KAP. Male patients received a higher KAP in all BMI categories. Limiting fluoroscopy time and good collimation practices should be reinforced in these patients. - Highlights: • Trainee involvement did not contribute to increased fluoroscopy time or dose. • BMI did not affect fluoroscopy time. • Overweight and obese patients received significantly higher Ka,r and KAP.

  11. In Situ SIMS and IR Spectroscopy of Well-Defined Surfaces Prepared by Soft Landing of Mass-Selected Ions

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Grant E.; Gunaratne, Kalupathirannehelage Don D.; Laskin, Julia

    2014-06-16

    Soft landing of mass-selected ions onto surfaces is a powerful approach for the highly-controlled preparation of materials that are inaccessible using conventional synthesis techniques. Coupling soft landing with in situ characterization using secondary ion mass spectrometry (SIMS) and infrared reflection absorption spectroscopy (IRRAS) enables analysis of well-defined surfaces under clean vacuum conditions. The capabilities of three soft-landing instruments constructed in our laboratory are illustrated for the representative system of surface-bound organometallics prepared by soft landing of mass-selected ruthenium tris(bipyridine) dications, [Ru(bpy)3]2+, onto carboxylic acid terminated self-assembled monolayer surfaces on gold (COOH-SAMs). In situ time-of-flight (TOF)-SIMS provides insight into the reactivity of the soft-landed ions. In addition, the kinetics of charge reduction, neutralization and desorption occurring on the COOH-SAM both during and after ion soft landing are studied using in situ Fourier transform ion cyclotron resonance (FT-ICR)-SIMS measurements. In situ IRRAS experiments provide insight into how the structure of organic ligands surrounding metal centers is perturbed through immobilization of organometallic ions on COOH-SAM surfaces by soft landing. Collectively, the three instruments provide complementary information about the chemical composition, reactivity and structure of well-defined species supported on surfaces.

  12. In situ SIMS and IR spectroscopy of well-defined surfaces prepared by soft landing of mass-selected ions.

    Science.gov (United States)

    Johnson, Grant E; Gunaratne, K Don Dasitha; Laskin, Julia

    2014-06-16

    Soft landing of mass-selected ions onto surfaces is a powerful approach for the highly-controlled preparation of materials that are inaccessible using conventional synthesis techniques. Coupling soft landing with in situ characterization using secondary ion mass spectrometry (SIMS) and infrared reflection absorption spectroscopy (IRRAS) enables analysis of well-defined surfaces under clean vacuum conditions. The capabilities of three soft-landing instruments constructed in our laboratory are illustrated for the representative system of surface-bound organometallics prepared by soft landing of mass-selected ruthenium tris(bipyridine) dications, [Ru(bpy)3](2+) (bpy = bipyridine), onto carboxylic acid terminated self-assembled monolayer surfaces on gold (COOH-SAMs). In situ time-of-flight (TOF)-SIMS provides insight into the reactivity of the soft-landed ions. In addition, the kinetics of charge reduction, neutralization and desorption occurring on the COOH-SAM both during and after ion soft landing are studied using in situ Fourier transform ion cyclotron resonance (FT-ICR)-SIMS measurements. In situ IRRAS experiments provide insight into how the structure of organic ligands surrounding metal centers is perturbed through immobilization of organometallic ions on COOH-SAM surfaces by soft landing. Collectively, the three instruments provide complementary information about the chemical composition, reactivity and structure of well-defined species supported on surfaces.

  13. Corrective Action Investigation plan for Corrective Action Unit 546: Injection Well and Surface Releases, Nevada Test Site, Nevada, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    Alfred Wickline

    2008-03-01

    Corrective Action Unit (CAU) 546 is located in Areas 6 and 9 of the Nevada Test Site, which is approximately 65 miles northwest of Las Vegas, Nevada. Corrective Action Unit 546 is comprised of two Corrective Action Sites (CASs) listed below: •06-23-02, U-6a/Russet Testing Area •09-20-01, Injection Well These sites are being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives. Additional information will be obtained by conducting a corrective action investigation (CAI) before evaluating corrective action alternatives and selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible evaluation of viable corrective action alternatives that will be presented in the Corrective Action Decision Document. The sites will be investigated based on the data quality objectives (DQOs) developed on November 8, 2007, by representatives of the Nevada Division of Environmental Protection and U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office. The DQO process has been used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective actions for CAU 546.

  14. Do galaxy global relationships emerge from local ones? The SDSS IV MaNGA surface mass density-metallicity relation

    Science.gov (United States)

    Barrera-Ballesteros, Jorge K.; Heckman, Timothy M.; Zhu, Guangtun B.; Zakamska, Nadia L.; Sánchez, Sebastian F.; Law, David; Wake, David; Green, Jenny E.; Bizyaev, Dmitry; Oravetz, Daniel; Simmons, Audrey; Malanushenko, Elena; Pan, Kaike; Roman Lopes, Alexandre; Lane, Richard R.

    2016-12-01

    We present the stellar surface mass density versus gas metallicity (Σ*-Z) relation for more than 500 000 spatially resolved star-forming resolution elements (spaxels) from a sample of 653 disc galaxies included in the SDSS IV MaNGA survey. We find a tight relation between these local properties, with higher metallicities as the surface density increases. This relation extends over three orders of magnitude in the surface mass density and a factor of 4 in metallicity. We show that this local relationship can simultaneously reproduce two well-known properties of disc galaxies: their global mass-metallicity relationship and their radial metallicity gradients. We also find that the Σ*-Z relation is largely independent of the galaxy's total stellar mass and specific star formation rate (sSFR), except at low stellar mass and high sSFR. These results suggest that in the present-day universe local properties play a key role in determining the gas-phase metallicity in typical disc galaxies.

  15. Surface Acoustic Wave Nebulisation Mass Spectrometry for the Fast and Highly Sensitive Characterisation of Synthetic Dyes in Textile Samples

    NARCIS (Netherlands)

    Astefanei, A.; van Bommel, M.; Corthals, G.L.

    2017-01-01

    Surface acoustic wave nebulisation (SAWN) mass spectrometry (MS) is a method to generate gaseous ions compatible with direct MS of minute samples at femtomole sensitivity. To perform SAWN, acoustic waves are propagated through a LiNbO3 sampling chip, and are conducted to the liquid sample, which

  16. Salinity maxima associated with some sub-surface water masses in the upper layers of the Bay of Bengal

    Digital Repository Service at National Institute of Oceanography (India)

    Varadachari, V.V.R.; Murty, C.S.; Reddy, C.V.G.

    The distribution of some sub-surface water masses in the western bay of Bengal during the south-west monsoon period is presented. Based on the salinity maxima and sigma t values the existence of waters of Persian Gulf and Red Sea origin could...

  17. Light curve of a meteoroid during quasi-continuous escape of particles with equal primary mass from the meteoroid surface

    International Nuclear Information System (INIS)

    Kalenichenko, V.V.

    1980-01-01

    Quasi-continuous escape of particles with equal primary mass from a meteoroid surface in the process of ablation is considered. An analytical light curve of the meteoroid is calculated. A series of physical parameters of meteoroids is obtained. The meanings of these parameters can be determined in comparison of the theory with experimental light curves of meteoroids

  18. Estimating Greenland ice sheet surface mass balance contribution to future sea level rise using the regional atmospheric climate model MAR

    NARCIS (Netherlands)

    Fettweis, X.; Franco, B.; Tedesco, M.; van Angelen, J.H.; Lenaerts, J.T.M.; van den Broeke, M.R.; Gallee, H

    2012-01-01

    We report future projections of Surface Mass Balance (SMB) over the Greenland ice sheet (GrIS) obtained with the regional climate model MAR, forced by the outputs of three CMIP5 General Circulation Models (GCMs) when considering two different warming scenarios (RCP 4.5 and RCP 8.5). The GCMs

  19. Method and apparatus for enhanced sequencing of complex molecules using surface-induced dissociation in conjunction with mass spectrometric analysis

    Science.gov (United States)

    Laskin, Julia [Richland, WA; Futrell, Jean H [Richland, WA

    2008-04-29

    The invention relates to a method and apparatus for enhanced sequencing of complex molecules using surface-induced dissociation (SID) in conjunction with mass spectrometric analysis. Results demonstrate formation of a wide distribution of structure-specific fragments having wide sequence coverage useful for sequencing and identifying the complex molecules.

  20. Combined use of atomic force microscopy, X-ray photoelectron spectroscopy, and secondary ion mass spectrometry for cell surface analysis.

    Science.gov (United States)

    Dague, Etienne; Delcorte, Arnaud; Latgé, Jean-Paul; Dufrêne, Yves F

    2008-04-01

    Understanding the surface properties of microbial cells is a major challenge of current microbiological research and a key to efficiently exploit them in biotechnology. Here, we used three advanced surface analysis techniques with different sensitivity, probing depth, and lateral resolution, that is, in situ atomic force microscopy, X-ray photoelectron spectroscopy, and secondary ion mass spectrometry, to gain insight into the surface properties of the conidia of the human fungal pathogen Aspergillus fumigatus. We show that the native ultrastructure, surface protein and polysaccharide concentrations, and amino acid composition of three mutants affected in hydrophobin production are markedly different from those of the wild-type, thereby providing novel insight into the cell wall architecture of A. fumigatus. The results demonstrate the power of using multiple complementary techniques for probing microbial cell surfaces.

  1. EFFECT OF VARIABLE VISCOSITY AND SUCTION/INJECTION ON THERMAL BOUNDARY LAYER OF A NON-NEWTONIAN POWER-LAW FLUIDS PAST A POWER-LAW STRETCHED SURFACE

    Directory of Open Access Journals (Sweden)

    Rania Fathy

    2010-01-01

    Full Text Available The analysis of laminar boundary layer flow and heat transfer of non-Newtonian fluids over a continuous stretched surface with suction or injection has been presented.The velocity and temperature of the sheet were assumed to vary in a power-law form, that is u = U0xm, and Tw(x = T+ Cxb. The viscosity of the fluid is assumed to be inverse linear function of temperature. The resulting governing boundary-layer equations are highly non-linear and coupled form of partial differential equations and they have been solved numerically by using the Runge-Kutta method and Shooting technique. Velocity and temperature distributions as well as the Nusselt number where studied for two thermal boundary conditions: uniform surface temperature (b = 0 and cooled surface temperature (b = -1, for different parameters: variable viscosity parameter qr, temperature exponent b, blowing parameter d and Prandtl number. The obtained results show that the flow and heat transfer characteristics are significantly influenced by these parameters.

  2. Surface modification of hexatriacontane by CF_4 plasmas studied by optical emission and threshold ionization mass spectrometries

    Science.gov (United States)

    Poncin-Epaillard, F.; Wang, W.; Ausserré, D.; Scharzenbach, W.; Derouard, J.; Sadeghi, N.

    1998-11-01

    The behavior of tetrafluoromethane microwave plasma (2% argon included) has been studied by emission spectroscopy during the treatment of hexatriacontane, a model for high density polyethylene. The evolution of the densities of F* atoms, and CF, CF^*2, radicals has been followed by using the actinometric technique with 2% argon added to the gas. The surface properties, such as surface energy and surface roughness were correlated to the emission intensity of reactives species in the plasma gas phase. We found that the evolution of the fluorinated species emissions in the plasma gas phase can be a direct indication of the surface modifications by the plasma. A mild exposure to the plasma can result in a great decrease of surface energy corresponding to the fluorination. The surface roughness only changes under drastic plasma conditions. Threshold ionization mass spectroscopy is applied to detect the fluorine atoms and CFx radicals. Time resolved measurements in pulsed plasma, give access to the decay rate of F atoms concentration in the afterglow, and to their sticking coefficient on different surfaces. The influences of the discharge parameters and of the surfaces (metal, silicon or hexatriacontane) in contact with the plasma are investigated. The results show that the plasma generated ions and/or UV radiations highly enhance the reactivity of the F atoms on polymer surface.

  3. Characterization of the intragranular water regime within subsurface sediments: pore volume, surface area, and mass transfer limitations

    Science.gov (United States)

    Hay, Michael B.; Stoliker, Deborah L.; Davis, James A.; Zachara, John M.

    2011-01-01

    Although "intragranular" pore space within grain aggregates, grain fractures, and mineral surface coatings may contain a relatively small fraction of the total porosity within a porous medium, it often contains a significant fraction of the reactive surface area, and can thus strongly affect the transport of sorbing solutes. In this work, we demonstrate a batch experiment procedure using tritiated water as a high-resolution diffusive tracer to characterize the intragranular pore space. The method was tested using uranium-contaminated sediments from the vadose and capillary fringe zones beneath the former 300A process ponds at the Hanford site (Washington). Sediments were contacted with tracers in artificial groundwater, followed by a replacement of bulk solution with tracer-free groundwater and the monitoring of tracer release. From these data, intragranular pore volumes were calculated and mass transfer rates were quantified using a multirate first-order mass transfer model. Tritium-hydrogen exchange on surface hydroxyls was accounted for by conducting additional tracer experiments on sediment that was vacuum dried after reaction. The complementary ("wet" and "dry") techniques allowed for the simultaneous determination of intragranular porosity and surface area using tritium. The Hanford 300A samples exhibited intragranular pore volumes of ~1% of the solid volume and intragranular surface areas of ~20%–35% of the total surface area. Analogous experiments using bromide ion as a tracer yielded very different results, suggesting very little penetration of bromide into the intragranular porosity.

  4. Corrective Action Decision Document/Closure Report for Corrective Action Unit 546: Injection Well and Surface Releases Nevada Test Site, Nevada, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    Alfred Wickline

    2008-12-01

    This Corrective Action Decision Document/Closure Report has been prepared for Corrective Action Unit 546, Injection Well and Surface Releases, at the Nevada Test Site, Nevada, in accordance with the Federal Facility Agreement and Consent Order (FFACO, 1996; as amended February 2008). Corrective Action Unit (CAU) 546 is comprised of two corrective action sites (CASs): • 06-23-02, U-6a/Russet Testing Area • 09-20-01, Injection Well The purpose of this Corrective Action Decision Document/Closure Report is to provide justification and documentation supporting the recommendation for closure of CAU 546. To achieve this, corrective action investigation (CAI) activities were performed from May 5 through May 28, 2008, as set forth in the Corrective Action Investigation Plan for Corrective Action Unit 546: Injection Well and Surface Releases, Nevada Test Site, Nevada (NNSA/NSO, 2008). The purpose of the CAI was to fulfill the following data needs as defined during the data quality objective (DQO) process: • Determine whether a contaminant of concern is present at a given CAS. • Determine whether sufficient information is available to evaluate potential corrective action alternatives at each CAS. The CAU 546 dataset from the investigation results was evaluated based on the data quality indicator parameters. This evaluation demonstrated the quality and acceptability of the dataset for use in fulfilling the DQO data needs. Because DQO data needs were met, and corrective actions have been implemented, it has been determined that no further corrective action (based on risk to human receptors) is necessary for the CAU 546 CASs. The U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office provides the following recommendations: • No further corrective actions are needed for CAU 546 CASs. • No Corrective Action Plan is required. • A Notice of Completion to the U.S. Department of Energy, National Nuclear Security Administration Nevada Site

  5. An HI selected sample of galaxies : The HI mass function and the surface brightness distribution

    NARCIS (Netherlands)

    Zwaan, M; Briggs, F; Sprayberry, D

    Results from the Arecibo HI Strip Survey, an unbiased extragalactic HI survey, combined with optical and 21 cm follow-up observations, determine the HI mass function and the cosmological mass density of HI at the present epoch. Both are consistent with earlier estimates, computed for the population

  6. Mass spectrometry imaging of surface lipids on intact Drosophila melanogaster flies

    Czech Academy of Sciences Publication Activity Database

    Kaftan, Filip; Vrkoslav, Vladimír; Kynast, P.; Kulkarni, P.; Böcker, S.; Cvačka, Josef; Knaden, M.; Svatoš, Aleš

    2014-01-01

    Roč. 49, č. 3 (2014), s. 223-232 ISSN 1076-5174 R&D Projects: GA ČR GA203/09/0139 Institutional support: RVO:61388963 Keywords : MALDI * laser desorption * mass spectrometric imaging * fruit flies * neutral lipids * sex pheromones * mass shift correction Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.379, year: 2014

  7. A MASS BALANCE OF SURFACE WATER GENOTOXICITY IN PROVIDENCE RIVER (RHODE ISLAND USA)

    Science.gov (United States)

    White and Rasmussen (Mutation Res. 410:223-236) used a mass balance approach to demonstrate that over 85% of the total genotoxic loading to the St. Lawrence River at Montreal is non-industrial. To validate the mass balance approach and investigate the sources of genotoxins in sur...

  8. How effective would solar geoengineering be at offsetting surface mass balance losses of the ice-sheets?

    Science.gov (United States)

    Irvine, P. J.; Keith, D.

    2016-12-01

    Studies of the sea-level rise response to solar geoengineering suggest that it could be highly effective at reducing sea-level rise by reducing thermal expansion of ocean waters and reducing the melting of land ice. However, all studies to date have employed simplistic treatments of surface mass balance where melt is a function only of surface air temperature and many have not had explicit treatments of accumulation. Solar geoengineering would counteract the longwave forcing of elevated greenhouse gas concentrations by reducing incoming solar radiation, changing the seasonal, latitudinal and vertical distribution of energy within the climate system. Climate model simulations suggest that solar geoengineering deployed to counter future warming from rising greenhouse gas concentrations could partially offset many climate trends associated with rising greenhouse gas concentrations, however it would lead to a suppression of the hydrological cycle as well as leading to substantial residual regional climate changes. In this study the response of the surface mass balance of the Greenland and Antarctic ice sheets to solar geoengineering will be investigated. Multi-model results from G1, the idealized solar insolation reduction experiment of the Geoengineering Model Intercomparison Project (GeoMIP), will be compared against results from the abrupt4×CO2 and piControl experiment. The energy and mass balance of the ice sheets, as well as the broader climate response in the polar regions will be analysed in the GeoMIP ensemble. This analysis will be complemented by offline surface mass balance simulations, including both those which directly simulate the energy balance and by those which use approximations based on surface air temperatures. This analysis will help to determine whether previous studies have over- or under-estimated the efficacy of solar geoengineering at offsetting future sea-level rise.

  9. The odd-proton effects on the potential energy surfaces of odd mass Tl, Au, Ir and Re isotopes

    CERN Document Server

    De Wieclawik, W; Larsson, S E; Leander, G; Vieu, C; Dionisio, J S

    1976-01-01

    The total potential energy surfaces of thallium, gold, iridium and rhenium odd mass isotopes are calculated microscopically as functions of the quadrupole deformation, epsilon /sub 2/, when the odd protons occupy definite orbitals. The nuclear shapes and the static equilibrium deformations of these nuclei are deduced from the results of these calculations for the proton orbitals nearest to the Fermi level. The influence of the hexadecapole deformation, epsilon /sub 4/, on these results is investigated too. Finally, a few experimental data available for these odd mass nuclei are correlated to the corresponding theoretical results. (16 refs).

  10. Characterization of anti-theft devices directly from the surface of banknotes via easy ambient sonic spray ionization mass spectrometry.

    Science.gov (United States)

    Schmidt, Eduardo Morgado; Franco, Marcos Fernando; Cuelbas, Claudio José; Zacca, Jorge Jardim; de Carvalho Rocha, Werickson Fortunato; Borges, Rodrigo; de Souza, Wanderley; Sawaya, Alexandra Christine Helena Frankland; Eberlin, Marcos Nogueira; Correa, Deleon Nascimento

    2015-09-01

    Using Brazilian banknotes as a test case, forensic examination and identification of Rhodamine B dye anti-theft device (ATD) staining on banknotes were performed. Easy ambient sonic spray ionization mass spectrometry (EASI-MS) was used since it allows fast and simple analysis with no sample preparation providing molecular screening of the surface with direct desorption and ionization of the security dye. For a more accurate molecular characterization of the ATD dye, Q Exactive Orbitrap™ Fourier transform (tandem) mass spectrometry using eletrospray ionization (ESI-HRMS/MS) was also applied. Copyright © 2015 The Chartered Society of Forensic Sciences. Published by Elsevier Ireland Ltd. All rights reserved.

  11. Two-step Laser Time-of-Flight Mass Spectrometry to Elucidate Organic Diversity in Planetary Surface Materials.

    Science.gov (United States)

    Getty, Stephanie A.; Brinckerhoff, William B.; Cornish, Timothy; Li, Xiang; Floyd, Melissa; Arevalo, Ricardo Jr.; Cook, Jamie Elsila; Callahan, Michael P.

    2013-01-01

    Laser desorption/ionization time-of-flight mass spectrometry (LD-TOF-MS) holds promise to be a low-mass, compact in situ analytical capability for future landed missions to planetary surfaces. The ability to analyze a solid sample for both mineralogical and preserved organic content with laser ionization could be compelling as part of a scientific mission pay-load that must be prepared for unanticipated discoveries. Targeted missions for this instrument capability include Mars, Europa, Enceladus, and small icy bodies, such as asteroids and comets.

  12. Observationally constrained surface mass balance of Larsen C ice shelf, Antarctica

    Directory of Open Access Journals (Sweden)

    P. Kuipers Munneke

    2017-11-01

    Full Text Available The surface mass balance (SMB of the Larsen C ice shelf (LCIS, Antarctica, is poorly constrained due to a dearth of in situ observations. Combining several geophysical techniques, we reconstruct spatial and temporal patterns of SMB over the LCIS. Continuous time series of snow height (2.5–6 years at five locations allow for multi-year estimates of seasonal and annual SMB over the LCIS. There is high interannual variability in SMB as well as spatial variability: in the north, SMB is 0.40 ± 0.06 to 0.41 ± 0.04 m w.e. year−1, while farther south, SMB is up to 0.50 ± 0.05 m w.e. year−1. This difference between north and south is corroborated by winter snow accumulation derived from an airborne radar survey from 2009, which showed an average snow thickness of 0.34 m w.e. north of 66° S, and 0.40 m w.e. south of 68° S. Analysis of ground-penetrating radar from several field campaigns allows for a longer-term perspective of spatial variations in SMB: a particularly strong and coherent reflection horizon below 25–44 m of water-equivalent ice and firn is observed in radargrams collected across the shelf. We propose that this horizon was formed synchronously across the ice shelf. Combining snow height observations, ground and airborne radar, and SMB output from a regional climate model yields a gridded estimate of SMB over the LCIS. It confirms that SMB increases from north to south, overprinted by a gradient of increasing SMB to the west, modulated in the west by föhn-induced sublimation. Previous observations show a strong decrease in firn air content toward the west, which we attribute to spatial patterns of melt, refreezing, and densification rather than SMB.

  13. Structural Definition and Mass Estimation of Lunar Surface Habitats for the Lunar Architecture Team Phase 2 (LAT-2) Study

    Science.gov (United States)

    Dorsey, John T.; Wu, K, Chauncey; Smith, Russell W.

    2008-01-01

    The Lunar Architecture Team Phase 2 study defined and assessed architecture options for a Lunar Outpost at the Moon's South Pole. The Habitation Focus Element Team was responsible for developing concepts for all of the Habitats and pressurized logistics modules particular to each of the architectures, and defined the shapes, volumes and internal layouts considering human factors, surface operations and safety requirements, as well as Lander mass and volume constraints. The Structures Subsystem Team developed structural concepts, sizing estimates and mass estimates for the primary Habitat structure. In these studies, the primary structure was decomposed into a more detailed list of components to be sized to gain greater insight into concept mass contributors. Structural mass estimates were developed that captured the effect of major design parameters such as internal pressure load. Analytical and empirical equations were developed for each structural component identified. Over 20 different hard-shell, hybrid expandable and inflatable soft-shell Habitat and pressurized logistics module concepts were sized and compared to assess structural performance and efficiency during the study. Habitats were developed in three categories; Mini Habs that are removed from the Lander and placed on the Lunar surface, Monolithic habitats that remain on the Lander, and Habitats that are part of the Mobile Lander system. Each category of Habitat resulted in structural concepts with advantages and disadvantages. The same modular shell components could be used for the Mini Hab concept, maximizing commonality and minimizing development costs. Larger Habitats had higher volumetric mass efficiency and floor area than smaller Habitats (whose mass was dominated by fixed items such as domes and frames). Hybrid and pure expandable Habitat structures were very mass-efficient, but the structures technology is less mature, and the ability to efficiently package and deploy internal subsystems

  14. Soret and Dufour effects on convective heat and mass transfer in stagnation-point flow towards a shrinking surface

    International Nuclear Information System (INIS)

    Bhattacharyya, Krishnendu; Layek, G C; Seth, G S

    2014-01-01

    A mathematical model is presented to study the Soret and Dufour effects on the convective heat and mass transfer in stagnation-point flow of viscous incompressible fluid towards a shrinking surface. Suitable similarity transformations are used to convert the governing partial differential equations into self-similarity ordinary differential equations that are then numerically solved by shooting method. Dual solutions for temperature and concentration are obtained in the presence of Soret and Dufour effects. Graphical representations of the heat and mass transfer coefficients, the dimensionless thermal and solute profiles for various values of Prandtl number, Lewis number, Soret number and Dufour number are demonstrated. With Soret number the mass transfer coefficient which is related to mass transfer rate increases for both solutions and the heat transfer coefficient (related to heat transfer rate) for both solutions becomes larger with Dufour number. The Prandtl number causes reduction in heat and the mass transfer coefficients and similarly with the Lewis number mass transfer coefficient decreases. Also, double crossing over is found in dual dimensionless temperature profiles for increasing Soret number and in dual dimensionless concentration profiles for the increase in Dufour number. Due to the larger values of Dufour number the thermal boundary layer increases and for Prandtl number increment it decreases; whereas, the solute boundary layer thickness reduces with increasing values of Prandtl number and Lewis number. (paper)

  15. Solvent Separating Secondary Metabolites Directly from Biosynthetic Tissue for Surface-Assisted Laser Desorption Ionisation Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    David Rudd

    2015-03-01

    Full Text Available Marine bioactive metabolites are often heterogeneously expressed in tissues both spatially and over time. Therefore, traditional solvent extraction methods benefit from an understanding of the in situ sites of biosynthesis and storage to deal with heterogeneity and maximize yield. Recently, surface-assisted mass spectrometry (MS methods namely nanostructure-assisted laser desorption ionisation (NALDI and desorption ionisation on porous silicon (DIOS surfaces have been developed to enable the direct detection of low molecular weight metabolites. Since direct tissue NALDI-MS or DIOS-MS produce complex spectra due to the wide variety of other metabolites and fragments present in the low mass range, we report here the use of “on surface” solvent separation directly from mollusc tissue onto nanostructured surfaces for MS analysis, as a mechanism for simplifying data annotation and detecting possible artefacts from compound delocalization during the preparative steps. Water, ethanol, chloroform and hexane selectively extracted a range of choline esters, brominated indoles and lipids from Dicathais orbita hypobranchial tissue imprints. These compounds could be quantified on the nanostructured surfaces by comparison to standard curves generated from the pure compounds. Surface-assisted MS could have broad utility for detecting a broad range of secondary metabolites in complex marine tissue samples.

  16. Real-time monitoring of the progress of polymerization reactions directly on surfaces at open atmosphere by ambient mass spectrometry.

    Science.gov (United States)

    Nørgaard, Asger W; Vaz, Boniek G; Lauritsen, Frants R; Eberlin, Marcos N

    2010-12-15

    The progress of an on-surface polymerization process involving alkyl and perfluoroalkyl silanes and siloxanes was monitored in real-time via easy ambient sonic spray ionization mass spectrometry (EASI-MS). When sprayed on surfaces, the organosilicon compounds present in commercially available nanofilm products (NFPs) react by condensation to form a polymeric coating. A NFP for coating of floor materials (NFP-1) and a second NFP for coating tiles and ceramics (NFP-2) were applied to glass, filter paper or cotton surfaces and the progress of the polymerization was monitored by slowly scanning the surface. Via EASI(+)-MS monitoring, significant changes in the composition of hydrolysates and condensates of 1H,1H,2H,2H-perfluorooctyl triisopropoxysilane (NFP-1) and hexadecyl triethoxysilane (NFP-2) were observed over time. The abundances of the hydrolyzed species decreased compared with those of the non-hydrolysed species for both NFP-1 and NFP-2 and the heavier oligomers became relatively more abundant over a period of 15-20 min. A similar tendency favouring the heavier oligomers was observed via EASI(-)-MS. This work illustrates the potential of ambient mass spectrometry for the direct monitoring of polymerization reactions on surfaces. Copyright © 2010 John Wiley & Sons, Ltd.

  17. An improved thin-layer chromatography/mass spectrometry coupling using a surface sampling probe electrospray ion trap system

    Energy Technology Data Exchange (ETDEWEB)

    Ford, Michael J [ORNL; Van Berkel, Gary J [ORNL

    2004-01-01

    A combined surface sampling probe/electrospray emitter coupled with an ion trap mass spectrometer was used for the direct read out of unmodified reversed-phase C18 thin-layer chromatography (TLC) plates. The operation of the surface sampling electrospray ionization interface in positive and negative ionization modes was demonstrated through the direct analysis of TLC plates on which a commercial test mix comprised of four dye compounds viz., rhodamine B, fluorescein, naphthol blue black, and fast green FCF, and an extract of the caffeine-containing plant Ilex vomitoria, were spotted and developed. Acquisition of full-scan mass spectra and automated collection of MS/MS product ion spectra while scanning a development lane along the surface of a TLC plate demonstrated the advantages of using an ion trap in this combination. Details of the sampling system, benefits of analyzing a developed lane in both positive ion and negative ion modes, levels of detection while surface scanning, surface scan speed effects, and the utility of three-dimensional data display, are also discussed.

  18. Forensic Sampling and Analysis from a Single Substrate: Surface-Enhanced Raman Spectroscopy Followed by Paper Spray Mass Spectrometry.

    Science.gov (United States)

    Fedick, Patrick W; Bills, Brandon J; Manicke, Nicholas E; Cooks, R Graham

    2017-10-17

    Sample preparation is the most common bottleneck in the analysis and processing of forensic evidence. Time-consuming steps in many forensic tests involve complex separations, such as liquid and gas chromatography or various types of extraction techniques, typically coupled with mass spectrometry (e.g., LC-MS). Ambient ionization ameliorates these slow steps by reducing or even eliminating sample preparation. While some ambient ionization techniques have been adopted by the forensic community, there is significant resistance to discarding chromatography as most forensic analyses require both an identification and a confirmation technique. Here, we describe the use of a paper substrate, the surface of which has been inkjet printed with silver nanoparticles, for surface enhanced Raman spectroscopy (SERS). The same substrate can also act as the paper substrate for paper spray mass spectrometry. The coupling of SERS and paper spray ionization creates a quick, forensically feasible combination.

  19. Seasonal differences in aerosol water may reconcile AOT and surface mass measurements in the Southeast U.S.

    Science.gov (United States)

    Nguyen, T. K. V.; Ghate, V. P.; Carlton, A. M. G.

    2015-12-01

    Summertime aerosol optical thickness (AOT) in the Southeast U.S. is high and sharply enhanced (2-3 times) compared to wintertime AOT. This seasonal pattern is unique to the Southeast U.S. and is of particular interest because temperatures there have not warmed over the past 100 years, contrasting with trends in other U.S. regions. Some investigators hypothesize the Southeast temperature trend is due to secondary organic aerosols (SOA) formed from interactions of biogenic volatile organic compounds (BVOCs) and anthropogenic emissions that create a cooling haze. However, aerosol measurements made at the surface do not exhibit strong seasonal differences in mass or organic fraction to support this hypothesis. In this work, we attempt to reconcile the spatial and temporal distribution of AOT over the U.S. with surface mass measurements by examining trends in particle-phase liquid water, an aerosol constituent that effectively scatters radiation and is removed from aerosols in mass measurements at routine surface monitoring sites. We employ the thermodynamic model ISORROPIA (v2.1) to estimate surface and aloft aerosol water mass concentrations at locations of Interagency Monitoring of Protected Visual Environments (IMPROVE) sites using measured speciated ion mass concentrations and NCEP North American Regional Reanalysis (NARR) meteorological data. Results demonstrate strong seasonal differences in aerosol water in the eastern compared to the western part of the U.S., consistent with geographic patterns in AOT. The highest mean regional seasonal difference from 2000 to 2007 is 5.5 μg m-3 and occurs the Southeast, while the lowest is 0.44 μg m-3 and occurs in the dry Mountain West. Our findings suggest 1) similarity between spatial trends in aerosol water in the U.S. and previously published AOT data from the MODIS-TERRA instrument and 2) similar interannual trends in mean aerosol water and previously published interannual AOT trends from MISR, MODIS-TERRA, MODIS

  20. Cell Surface Proteome of Dental Pulp Stem Cells Identified by Label-Free Mass Spectrometry.

    Directory of Open Access Journals (Sweden)

    Christian Niehage

    Full Text Available Multipotent mesenchymal stromal cells (MSCs are promising tools for regenerative medicine. They can be isolated from different sources based on their plastic-adherence property. The identification of reliable cell surface markers thus becomes the Holy Grail for their prospective isolation. Here, we determine the cell surface proteomes of human dental pulp-derived MSCs isolated from single donors after culture expansion in low (2% or high (10% serum-containing media. Cell surface proteins were tagged on intact cells using cell impermeable, cleavable sulfo-NHS-SS-biotin, which allows their enrichment by streptavidin pull-down. For the proteomic analyses, we first compared label-free methods to analyze cell surface proteomes i.e. composition, enrichment and proteomic differences, and we developed a new mathematical model to determine cell surface protein enrichment using a combinatorial gene ontology query. Using this workflow, we identified 101 cluster of differentiation (CD markers and 286 non-CD cell surface proteins. Based on this proteome profiling, we identified 14 cell surface proteins, which varied consistently in abundance when cells were cultured under low or high serum conditions. Collectively, our analytical methods provide a basis for identifying the cell surface proteome of dental pulp stem cells isolated from single donors and its evolution during culture or differentiation. Our data provide a comprehensive cell surface proteome for the precise identification of dental pulp-derived MSC populations and their isolation for potential therapeutic intervention.

  1. Direct surface analysis coupled to high-resolution mass spectrometry reveals heterogeneous composition of the cuticle of Hibiscus trionum petals.

    Science.gov (United States)

    Giorio, Chiara; Moyroud, Edwige; Glover, Beverley J; Skelton, Paul C; Kalberer, Markus

    2015-10-06

    Plant cuticle, which is the outermost layer covering the aerial parts of all plants including petals and leaves, can present a wide range of patterns that, combined with cell shape, can generate unique physical, mechanical, or optical properties. For example, arrays of regularly spaced nanoridges have been found on the dark (anthocyanin-rich) portion at the base of the petals of Hibiscus trionum. Those ridges act as a diffraction grating, producing an iridescent effect. Because the surface of the distal white region of the petals is smooth and noniridescent, a selective chemical characterization of the surface of the petals on different portions (i.e., ridged vs smooth) is needed to understand whether distinct cuticular patterns correlate with distinct chemical compositions of the cuticle. In the present study, a rapid screening method has been developed for the direct surface analysis of Hibiscus trionum petals using liquid extraction surface analysis (LESA) coupled with high-resolution mass spectrometry. The optimized method was used to characterize a wide range of plant metabolites and cuticle monomers on the upper (adaxial) surface of the petals on both the white/smooth and anthocyanic/ridged regions, and on the lower (abaxial) surface, which is entirely smooth. The main components detected on the surface of the petals are low-molecular-weight organic acids, sugars, and flavonoids. The ridged portion on the upper surface of the petal is enriched in long-chain fatty acids, which are constituents of the wax fraction of the cuticle. These compounds were not detected on the white/smooth region of the upper petal surface or on the smooth lower surface.

  2. Mass balance and surface movement of the Greenland Ice Sheet at Summit, Central Greenland

    DEFF Research Database (Denmark)

    Hvidberg, C.S.; Keller, K.; Gundestrup, N.S.

    1997-01-01

    During the GRIP deep drilling in Central Greenland, the ice sheet topography and surface movement at Summit has been mapped with GPS. Measurements of the surface velocity are presented for a strain net consisting of 13 poles at distances of 25-60 km from the GRIP site. Some results are: The GRIP...

  3. GLACIOCLIM-SAMBA: A Terre Adelie / Wilkes Land Antarctic surface mass balance observatory

    Science.gov (United States)

    Genthon, C.; Frezzotti, M.; Le Meur, E.; Magand, O.; Six, D.; Wagnon, P.

    2005-12-01

    While local measurements at hundreds of sites are now available (although sometimes questionable, e.g. Magand et al., this volume) to verify how large-scale models reproduce the spatial distribution of the surface mass balance (SMB) of Antarctica, few field observations yet make it possible to verify current intra- and inter-annual variability and trends of the SMB in the models, and to evaluate the processes that relate this variability with that of climate. It is a major aim of the GLACIOCLIM-SAMBA observatory (http://lgge.obs.ujf-grenoble.fr/~christo/glacioclim/samba/), initiated in 2004, to provide such observations in the Terre Adelie and Wilkes Land area. Recognizing that the largest absolute changes (and thus contribution to sea-level) of Antarctic SMB are expected where the current mean SMB is largest, that is in the coastal regions, SAMBA is largely focused on ice sheet margin. To sample spatial scales compatible with the scales resolved by models used to predict climate and SMB changes, a 150 km accumulation stakes line is being set up from the coast near the French Dumont d'Urville station, towards to Antarctic plateau in the general direction of the Italy/France Concordia station. Ground penetrating radar survey will provide snap-shot SMB interpolation along the stakes line. A blue ice stretch at the coast is being monitored by a 50-stake ablation network. Three 50-stakes networks are being set up near Concordia station to relate coastal and plateau SMB variability and change. An automatic weather station (AWS, including radiation) deployed at the coast, and the D-10, D-47 and DCII Antarctic Meteorological Research Center (http://amrc.ssec.wisc.edu/) AWSs, provide meteorological information to relate observed SMB and climate. Italian meteorology and radiation programs at Concordia, planned micrometeorology special campaigns at the margin, and precipitation monitoring at both sites, should help decipher the processes that relate SMB and climate

  4. Detecting kinematic boundary surfaces in phase space and particle mass measurements in SUSY-like events

    CERN Document Server

    Debnath, Dipsikha; Kilic, Can; Kim, Doojin; Matchev, Konstantin T.; Yang, Yuan-Pao

    2017-06-19

    We critically examine the classic endpoint method for particle mass determination, focusing on difficult corners of parameter space, where some of the measurements are not independent, while others are adversely affected by the experimental resolution. In such scenarios, mass differences can be measured relatively well, but the overall mass scale remains poorly constrained. Using the example of the standard SUSY decay chain $\\tilde q\\to \\tilde\\chi^0_2\\to \\tilde \\ell \\to \\tilde \\chi^0_1$, we demonstrate that sensitivity to the remaining mass scale parameter can be recovered by measuring the two-dimensional kinematical boundary in the relevant three-dimensional phase space of invariant masses squared. We develop an algorithm for detecting this boundary, which uses the geometric properties of the Voronoi tessellation of the data, and in particular, the relative standard deviation (RSD) of the volumes of the neighbors for each Voronoi cell in the tessellation. We propose a new observable, $\\bar\\Sigma$, which is ...

  5. Detecting kinematic boundary surfaces in phase space: particle mass measurements in SUSY-like events

    CERN Document Server

    Debnath, Dipsikha; Kilic, Can; Kim, Doojin; Matchev, Konstantin T.; Yang, Yuan-Pao

    2017-06-19

    We critically examine the classic endpoint method for particle mass determination, focusing on difficult corners of parameter space, where some of the measurements are not independent, while others are adversely affected by the experimental resolution. In such scenarios, mass differences can be measured relatively well, but the overall mass scale remains poorly constrained. Using the example of the standard SUSY decay chain $\\tilde q\\to \\tilde\\chi^0_2\\to \\tilde \\ell \\to \\tilde \\chi^0_1$, we demonstrate that sensitivity to the remaining mass scale parameter can be recovered by measuring the two-dimensional kinematical boundary in the relevant three-dimensional phase space of invariant masses squared. We develop an algorithm for detecting this boundary, which uses the geometric properties of the Voronoi tessellation of the data, and in particular, the relative standard deviation (RSD) of the volumes of the neighbors for each Voronoi cell in the tessellation. We propose a new observable, $\\bar\\Sigma$, which is t...

  6. Rapid Determination of Plutonium Isotopes in Environmental Samples Using Sequential Injection Extraction Chromatography and Detection by Inductively Coupled Plasma Mass Spectrometry

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per

    2009-01-01

    This article presents an automated method for the rapid determination of 239Pu and 240Pu in various environmental samples. The analytical method involves the in-line separation of Pu isotopes using extraction chromatography (TEVA) implemented in a sequential injection (SI) network followed...... of the in-line extraction chromatographic run was...

  7. On the Utilization of Ice Flow Models and Uncertainty Quantification to Interpret the Impact of Surface Radiation Budget Errors on Estimates of Greenland Ice Sheet Surface Mass Balance and Regional Estimates of Mass Balance

    Science.gov (United States)

    Schlegel, N.; Larour, E. Y.; Gardner, A. S.; Lang, C.; Miller, C. E.; van den Broeke, M. R.

    2016-12-01

    How Greenland ice flow may respond to future increases in surface runoff and to increases in the frequency of extreme melt events is unclear, as it requires detailed comprehension of Greenland surface climate and the ice sheet's sensitivity to associated uncertainties. With established uncertainty quantification tools run within the framework of Ice Sheet System Model (ISSM), we conduct decadal-scale forward modeling experiments to 1) quantify the spatial resolution needed to effectively force distinct components of the surface radiation budget, and subsequently surface mass balance (SMB), in various regions of the ice sheet and 2) determine the dynamic response of Greenland ice flow to variations in components of the net radiation budget. The Glacier Energy and Mass Balance (GEMB) software is a column surface model (1-D) that has recently been embedded as a module within ISSM. Using the ISSM-GEMB framework, we perform sensitivity analyses to determine how perturbations in various components of the surface radiation budget affect model output; these model experiments allow us predict where and on what spatial scale the ice sheet is likely to dynamically respond to changes in these parameters. Preliminary results suggest that SMB should be forced at at least a resolution of 23 km to properly capture dynamic ice response. In addition, Monte-Carlo style sampling analyses reveals that the areas with the largest uncertainty in mass flux are located near the equilibrium line altitude (ELA), upstream of major outlet glaciers in the North and West of the ice sheet. Sensitivity analysis indicates that these areas are also the most vulnerable on the ice sheet to persistent, far-field shifts in SMB, suggesting that continued warming, and upstream shift in the ELA, are likely to result in increased velocities, and consequentially SMB-induced thinning upstream of major outlet glaciers. Here, we extend our investigation to consider various components of the surface radiation

  8. Impact of improved Greenland ice sheet surface representation in the NASA GISS ModelE2 GCM on simulated surface mass balance and regional climate

    Science.gov (United States)

    Alexander, P. M.; LeGrande, A. N.; Fischer, E.; Tedesco, M.; Kelley, M.; Schmidt, G. A.; Fettweis, X.

    2017-12-01

    Towards achieving coupled simulations between the NASA Goddard Institute for Space Studies (GISS) ModelE2 general circulation model (GCM) and ice sheet models (ISMs), improvements have been made to the representation of the ice sheet surface in ModelE2. These include a sub-grid-scale elevation class scheme, a multi-layer snow model, a time-variable surface albedo scheme, and adjustments to parameterization of sublimation/evaporation. These changes improve the spatial resolution and physical representation of the ice sheet surface such that the surface is represented at a level of detail closer to that of Regional Climate Models (RCMs). We assess the impact of these changes on simulated Greenland Ice Sheet (GrIS) surface mass balance (SMB). We also compare ModelE2 simulations in which winds have been nudged to match the European Center for Medium-Range Weather Forecasts (ECMWF) ERA-Interim reanalysis with simulations from the Modèle Atmosphérique Régionale (MAR) RCM forced by the same reanalysis. Adding surface elevation classes results in a much higher spatial resolution representation of the surface necessary for coupling with ISMs, but has a negligible impact on overall SMB. Implementing a variable surface albedo scheme increases melt by 100%, bringing it closer to melt simulated by MAR. Adjustments made to the representation of topography-influenced surface roughness length in ModelE2 reduce a positive bias in evaporation relative to MAR. We also examine the impact of changes to the GrIS surface on regional atmospheric and oceanic climate in coupled ocean-atmosphere simulations with ModelE2, finding a general warming of the Arctic due to a warmer GrIS, and a cooler North Atlantic in scenarios with doubled atmospheric CO2 relative to pre-industrial levels. The substantial influence of changes to the GrIS surface on the oceans and atmosphere highlight the importance of including these processes in the GCM, in view of potential feedbacks between the ice sheet

  9. The Anomalies of Hyaluronan Structures in Presence of Surface Active Phospholipids—Molecular Mass Dependence

    Directory of Open Access Journals (Sweden)

    Piotr Bełdowski

    2018-03-01

    Full Text Available Interactions between hyaluronan (A- and phospholipids play a key role in many systems in the human body. One example is the articular cartilage system, where the synergistic effect of such interactions supports nanoscale lubrication. A molecular dynamics simulation has been performed to understand the process of formation of hydrogen bonds inside the hyaluronan network, both in the presence and absence of phospholipids. Additionally, the effect of the molecular mass of (A- was analyzed. The main finding of this work is a robust demonstration of the optimal parameters (H-bond energy, molecular mass influencing the facilitated lubrication mechanism of the articular cartilage system. Simulation results show that the presence of phospholipids has the greatest influence on hyaluronan at low molecular mass. We also show the specific sites of H-bonding between chains. Simulation results can help to understand how hyaluronan and phospholipids interact at several levels of articular cartilage system functioning.

  10. The influence of surface treatment on mass transfer between air and building material

    DEFF Research Database (Denmark)

    Kwiatkowski, Jerzy; Rode, Carsten; Hansen, Kurt Kielsgaard

    2008-01-01

    The processes of mass transfer between air and building structure and in the material influence not only the conditions within the material but also inside the connected air spaces. The material which absorbs and desorbs water vapour can be used to moderate the amplitude of indoor relative humidity...... and therefore to participate in the improvement of the indoor air quality and energy saving. Many parameters influence water vapour exchange between indoor air and building material. The aim of this work is to present the change of mass transfer under different climatic and material conditions. The measurements...... for the experiments: gypsum board and calcium silicate. The wallpaper and paint were used as finishing materials. Impact of the following parameters for changes of RH was studied: coating, temperature and air movement. The measurements showed that acryl paint (diffusion open) can significantly decrease mass uptake...

  11. DOTS: A High Resolution Orbitrap Mass Spectrometer for In Situ Analysis of the surface samples of Airless Planetary Bodies

    Science.gov (United States)

    Briois, Christelle; Thissen, Roland; Engrand, Cécile; Altwegg, Kathrin; Bouabdellah, Abdel; Boukrara, Amirouche; Carrasco, Nathalie; Chapuis, Claude; Cottin, Hervé; Grün, Eberhard; Grand, Noel; Henkel, Hartmut; Kempf, Sascha; Lebreton, Jean-Pierre; Makarov, Alexander A.; Postber, Frank; Srama, Ralf; Schmidt, Jürgen; Szopa, Cyril; Thirkell, Laurent; Tobie, Gabriel; Wurz, Peter; Zolotov, Mikhail Yu

    2013-04-01

    The dust detectors on board the Ulysses and Galileo spacecraft have shown that the Galilean satellites are surrounded by clouds of sub-micrometer size grains generated by impacts of interplanetary (micro-) meteoroids [1, 2]. In situ chemical analysis from orbit of these ballistic grains ejected from the surface of airless bodies provides a unique opportunity to remotely access the chemical composition of the Jovian moons' surface and subsurface. For Saturn, in situ identification by the Cassini Dust Analyzer (CDA) of sodium in icy grains in the E-Ring and in Enceladus plumes have proven a subsurface liquid water reservoir inside Enceladus [3, 4]. Noticeably, this was not accessible to other in situ or traditional remote sensing techniques. In situ measurements, either during a flyby or from orbit, of grains ejected from the surface, or emerging from the subsurface, of an airless body is a powerful tool to remotely study its surface composition and the nature of its geological activity. Crucial constraints on habitability can thus be determined. Our consortium of laboratories, in collaboration with Thermo Fischer Scientific [5, 6], is currently developing a high mass resolution Fourier Transform (FT) Orbitrap-based mass spectrometer optimized for in situ analysis of dust and icy grains in the environment of Solar System airless bodies. This new generation of dust mass spectrometer was studied in the framework of the Europa Jupiter System Mission (EJSM) instrument study in 2010-2012 and proposed in response to ESA's AO for the JUpiter ICy moons Explorer (JUICE) mission [7]. This mass analyser can provide very high mass resolution analysis (M/ΔM reaching 50 000 at m/z 50 Da). DOTS would allow identification of elemental and molecular species with excellent accuracy, in the 20-1000 Da mass range. In the context of the JUICE mission, DOTS would provide decisive information on the surface composition and on the putative liquid oceans in the subsurface of Ganymede

  12. Probing Sub-GeV Mass Strongly Interacting Dark Matter with a Low-Threshold Surface Experiment.

    Science.gov (United States)

    Davis, Jonathan H

    2017-11-24

    Using data from the ν-cleus detector, based on the surface of Earth, we place constraints on dark matter in the form of strongly interacting massive particles (SIMPs) which interact with nucleons via nuclear-scale cross sections. For large SIMP-nucleon cross sections, the sensitivity of traditional direct dark matter searches using underground experiments is limited by the energy loss experienced by SIMPs, due to scattering with the rock overburden and experimental shielding on their way to the detector apparatus. Hence, a surface-based experiment is ideal for a SIMP search, despite the much larger background resulting from the lack of shielding. We show using data from a recent surface run of a low-threshold cryogenic detector that values of the SIMP-nucleon cross section up to approximately 10^{-27}  cm^{2} can be excluded for SIMPs with masses above 100 MeV.

  13. The response of surface mass and energy balance of a continental glacier to climate variability, western Qilian Mountains, China

    Science.gov (United States)

    Sun, Weijun; Qin, Xiang; Wang, Yetang; Chen, Jizu; Du, Wentao; Zhang, Tong; Huai, Baojuan

    2017-08-01

    To understand how a continental glacier responds to climate change, it is imperative to quantify the surface energy fluxes and identify factors controlling glacier mass balance using surface energy balance (SEB) model. Light absorbing impurities (LAIs) at the glacial surface can greatly decrease surface albedo and increase glacial melt. An automatic weather station was set up and generated a unique 6-year meteorological dataset for the ablation zone of Laohugou Glacier No. 12. Based on these data, the surface energy budget was calculated and an experiment on the glacial melt process was carried out. The effect of reduced albedo on glacial melting was analyzed. Owing to continuous accumulation of LAIs, the ablation zone had been darkening since 2010. The mean value of surface albedo in melt period (June through September) dropped from 0.52 to 0.43, and the minimum of daily mean value was as small as 0.1. From the records of 2010-2015, keeping the clean ice albedo fixed in the range of 0.3-0.4, LAIs caused an increase of +7.1 to +16 W m-2 of net shortwave radiation and an removal of 1101-2663 mm water equivalent. Calculation with the SEB model showed equivalent increases in glacial melt were obtained by increasing air temperature by 1.3 and 3.2 K, respectively.

  14. Analytical mass formula and nuclear surface properties in the ETF approximation. Part II: asymmetric nuclei

    Science.gov (United States)

    Aymard, François; Gulminelli, Francesca; Margueron, Jérôme

    2016-08-01

    We have recently addressed the problem of the determination of the nuclear surface energy for symmetric nuclei in the framework of the extended Thomas-Fermi (ETF) approximation using Skyrme functionals. We presently extend this formalism to the case of asymmetric nuclei and the question of the surface symmetry energy. We propose an approximate expression for the diffuseness and the surface energy. These quantities are analytically related to the parameters of the energy functional. In particular, the influence of the different equation of state parameters can be explicitly quantified. Detailed analyses of the different energy components (local/non-local, isoscalar/isovector, surface/curvature and higher order) are also performed. Our analytical solution of the ETF integral improves previous models and leads to a precision of better than 200 keV per nucleon in the determination of the nuclear binding energy for dripline nuclei.

  15. Cefazolin Injection

    Science.gov (United States)

    ... is used to treat certain infections caused by bacteria including skin, bone, joint, genital, blood, heart valve, respiratory tract (including pneumonia), biliary tract, and urinary tract infections. Cefazolin injection ...

  16. Atezolizumab Injection

    Science.gov (United States)

    ... is in a class of medications called monoclonal antibodies. It works by blocking the action of a ... infection breath that smells fruity slowed, fast or irregular heartbeat Atezolizumab injection may cause other side effects. ...

  17. Cidofovir Injection

    Science.gov (United States)

    Cidofovir injection is used along with another medication (probenecid) to treat cytomegaloviral retinitis (CMV retinitis) in people ... body's response to the medication.You must take probenecid tablets by mouth with each dose of cidofovir. ...

  18. Acyclovir Injection

    Science.gov (United States)

    ... It is also used to treat first-time genital herpes outbreaks (a herpes virus infection that causes sores ... in the body. Acyclovir injection will not cure genital herpes and may not stop the spread of genital ...

  19. Alirocumab Injection

    Science.gov (United States)

    ... further decrease the amount of low-density lipoprotein (LDL) cholesterol ('bad cholesterol') in the blood. Alirocumab injection is ... antibodies. It works by blocking the production of LDL cholesterol in the body to decrease the amount of ...

  20. Pegloticase Injection

    Science.gov (United States)

    ... doctor if you have glucose-6-phosphate dehydrogenase (G6PD) deficiency (an inherited blood disease). Your doctor may test you for G6PD deficiency before you start to receive pegloticase injection. If ...

  1. Risperidone Injection

    Science.gov (United States)

    ... of interest in life, and strong or inappropriate emotions). Risperidone extended-release injection is used alone or ... during your treatment: extreme thirst, frequent urination, extreme hunger, blurred vision, or weakness. It is very important ...

  2. Olanzapine Injection

    Science.gov (United States)

    ... of interest in life, and strong or inappropriate emotions). Olanzapine injection is used to treat episodes of ... during your treatment: extreme thirst, frequent urination, extreme hunger, blurred vision, or weakness. It is very important ...

  3. Tacrolimus Injection

    Science.gov (United States)

    ... in people who have received kidney, liver, or heart transplants. Tacrolimus injection should only be used by people ... or nurse will watch you closely during the first 30 minutes of your treatment and then will ...

  4. Omalizumab Injection

    Science.gov (United States)

    ... injection is used to decrease the number of asthma attacks (sudden episodes of wheezing, shortness of breath, and ... about how to treat symptoms of a sudden asthma attack. If your asthma symptoms get worse or if ...

  5. Daclizumab Injection

    Science.gov (United States)

    ... neck, armpits, or groin; diarrhea; bloody stools; stomach pain; or any new, unexplained symptom affecting any part of your body.Because of the risks with this medication, daclizumab injection is available only through a special ...

  6. Temozolomide Injection

    Science.gov (United States)

    ... balance or coordination fainting dizziness hair loss insomnia memory problems pain, itching, swelling, or redness in the place where the medication was injected changes in vision Some side effects can be serious. If you ...

  7. Moxifloxacin Injection

    Science.gov (United States)

    ... tendon area, or inability to move or to bear weight on an affected area.Using moxifloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  8. Delafloxacin Injection

    Science.gov (United States)

    ... a tendon area, or inability to move or bear weight on an affected area.Using delafloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  9. Levofloxacin Injection

    Science.gov (United States)

    ... tendon area, or inability to move or to bear weight on an affected area.Using levofloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  10. Ciprofloxacin Injection

    Science.gov (United States)

    ... a tendon area, or inability to move or bear weight on an affected area.Using ciprofloxacin injection ... muscle weakness) and cause severe difficulty breathing or death. Tell your doctor if you have myasthenia gravis. ...

  11. Butorphanol Injection

    Science.gov (United States)

    ... Butorphanol is in a class of medications called opioid agonist-antagonists. It works by changing the way ... suddenly stop using butorphanol injection, you may experience withdrawal symptoms such as nervousness, agitation, shakiness, diarrhea, chills, ...

  12. Haloperidol Injection

    Science.gov (United States)

    ... of interest in life, and strong or inappropriate emotions). Haloperidol injection is also used to control motor ... and the laboratory. Your doctor may order certain lab tests to check your body's response to haloperidol ...

  13. Ketorolac Injection

    Science.gov (United States)

    ... of ketorolac by intravenous (into a vein) or intramuscular (into a muscle) injection in a hospital or ... You can also visit the Food and Drug Administration (FDA) website (http://www.fda.gov/Drugs/DrugSafety/ ...

  14. Temperature coefficient for modeling denitrification in surface water sediments using the mass transfer coefficient

    Science.gov (United States)

    T.W. Appelboom; G.M. Chescheir; F. Birgand; R.W. Skaggs; J.W. Gilliam; D. Amatya

    2010-01-01

    Watershed modeling has become an important tool for researchers. Modeling nitrate transport within drainage networks requires quantifying the denitrification within the sediments in canals and streams. In a previous study, several of the authors developed an equation using a term called a mass transfer coefficient to mathematically describe sediment denitrification....

  15. Temperature Coefficient for Modeling Denitrification in Surface Water Sediments Using the Mass Transfer Coefficient

    Science.gov (United States)

    T. W. Appelboom; G. M. Chescheir; R. W. Skaggs; J. W. Gilliam; Devendra M. Amatya

    2006-01-01

    Watershed modeling has become an important tool for researchers with the high costs of water quality monitoring. When modeling nitrate transport within drainage networks, denitrification within the sediments needs to be accounted for. Birgand et. al. developed an equation using a term called a mass transfer coefficient to mathematically describe sediment...

  16. Gas–Liquid Mass Transfer to Single Bubbles: Effect of Surface Contamination.

    Czech Academy of Sciences Publication Activity Database

    Vasconcelos, J.M.T.; Orvalho, Sandra; Alves, S. S.

    2002-01-01

    Roč. 48, 6 (2002) , s. 1145-1154 ISSN 0001-1541 Institutional research plan: CEZ:AV0Z4072921 Keywords : bubble * mass tranfer * stagnant-cap model Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 1.626, year: 2002

  17. Examination and Manipulation of Protein Surface Charge in Solution with Electrospray Ionization Mass Spectrometry

    Science.gov (United States)

    Gross, Deborah S.; Van Ryswyk, Hal

    2014-01-01

    Electrospray ionization mass spectrometry (ESI-MS) is a powerful tool for examining the charge of proteins in solution. The charge can be manipulated through choice of solvent and pH. Furthermore, solution-accessible, protonated lysine side chains can be specifically tagged with 18-crown-6 ether to form noncovalent adducts. Chemical derivatization…

  18. Reconstruction of the 1979–2006 Greenland ice sheet surface mass balance using the regional climate model MAR

    Directory of Open Access Journals (Sweden)

    X. Fettweis

    2007-10-01

    Full Text Available Results from a 28-year simulation (1979–2006 over the Greenland ice sheet (GrIS reveal an increase of solid precipitation (+0.4±2.5 km3 yr−2 and run-off (+7.9±3.3 km3 yr−2 of surface meltwater. The net effect of these competing factors is a significant Surface Mass Balance (SMB loss of −7.2±5.1 km3 yr−2. The contribution of changes in the net water vapour flux (+0.02±0.09 km3 yr−2 and rainfall (+0.2±0.2 km3 yr−2 to the SMB variability is negligible. The meltwater supply has increased because the GrIS surface has been warming up +2.4°C since 1979. Sensible heat flux, latent heat flux and net solar radiation have not varied significantly over the last three decades. However, the simulated downward infrared flux has increased by 9.3 W m−2 since 1979. The natural climate variability (e.g. the North Atlantic Oscillation does not explain these changes. The recent global warming, due to the greenhouse gas concentration increase induced by human activities, could be a cause of these changes. The doubling of surface meltwater flux into the ocean over the period 1979–2006 suggests that the overall ice sheet mass balance has been increasingly negative, given the likely meltwater-induced acceleration of outlet glaciers. This study suggests that increased melting overshadows over an increased accumulation in a warming scenario and that the GrIS is likely to keep losing mass in the future. An enduring GrIS melting will probably affect in the future an certain effect on the stability of the thermohaline circulation and the global sea level rise.

  19. GAS SURFACE DENSITY, STAR FORMATION RATE SURFACE DENSITY, AND THE MAXIMUM MASS OF YOUNG STAR CLUSTERS IN A DISK GALAXY. II. THE GRAND-DESIGN GALAXY M51

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez-Lopezlira, Rosa A. [On sabbatical leave from the Centro de Radioastronomia y Astrofisica, UNAM, Campus Morelia, Michoacan, C.P. 58089, Mexico. (Mexico); Pflamm-Altenburg, Jan; Kroupa, Pavel, E-mail: r.gonzalez@crya.unam.mx [Argelander Institut fuer Astronomie, Universitaet Bonn, Auf dem Huegel 71, D-53121 Bonn (Germany)

    2013-06-20

    We analyze the relationship between maximum cluster mass and surface densities of total gas ({Sigma}{sub gas}), molecular gas ({Sigma}{sub H{sub 2}}), neutral gas ({Sigma}{sub H{sub I}}), and star formation rate ({Sigma}{sub SFR}) in the grand-design galaxy M51, using published gas data and a catalog of masses, ages, and reddenings of more than 1800 star clusters in its disk, of which 223 are above the cluster mass distribution function completeness limit. By comparing the two-dimensional distribution of cluster masses and gas surface densities, we find for clusters older than 25 Myr that M{sub 3rd}{proportional_to}{Sigma}{sub H{sub I}{sup 0.4{+-}0.2}}, whereM{sub 3rd} is the median of the five most massive clusters. There is no correlation with{Sigma}{sub gas},{Sigma}{sub H2}, or{Sigma}{sub SFR}. For clusters younger than 10 Myr, M{sub 3rd}{proportional_to}{Sigma}{sub H{sub I}{sup 0.6{+-}0.1}} and M{sub 3rd}{proportional_to}{Sigma}{sub gas}{sup 0.5{+-}0.2}; there is no correlation with either {Sigma}{sub H{sub 2}} or{Sigma}{sub SFR}. The results could hardly be more different from those found for clusters younger than 25 Myr in M33. For the flocculent galaxy M33, there is no correlation between maximum cluster mass and neutral gas, but we have determined M{sub 3rd}{proportional_to}{Sigma}{sub gas}{sup 3.8{+-}0.3}, M{sub 3rd}{proportional_to}{Sigma}{sub H{sub 2}{sup 1.2{+-}0.1}}, and M{sub 3rd}{proportional_to}{Sigma}{sub SFR}{sup 0.9{+-}0.1}. For the older sample in M51, the lack of tight correlations is probably due to the combination of strong azimuthal variations in the surface densities of gas and star formation rate, and the cluster ages. These two facts mean that neither the azimuthal average of the surface densities at a given radius nor the surface densities at the present-day location of a stellar cluster represent the true surface densities at the place and time of cluster formation. In the case of the younger sample, even if the clusters have not yet

  20. Electrode quenching control for highly efficient CsPbBr3 perovskite light-emitting diodes via surface plasmon resonance and enhanced hole injection by Au nanoparticles

    Science.gov (United States)

    Meng, Yan; Wu, Xiaoyan; Xiong, Ziyang; Lin, Chunyan; Xiong, Zuhong; Blount, Ethan; Chen, Ping

    2018-04-01

    Compared to organic-inorganic hybrid metal halide perovskites, all-inorganic cesium lead halides (e.g, CsPbBr3) hold greater promise in being emissive materials for light-emitting diodes owing to their superior optoelectronic properties as well as their higher stabilities. However, there is still considerable potential for breakthroughs in the current efficiency of CsPbBr3 perovskite light-emitting diodes (PeLEDs). Electrode quenching is one of the main problems limiting the current efficiency of PeLEDs when poly(3,4-ethylenedioxythiophene): poly(styrenesulfonate) (PEDOT:PSS) is used as the hole injection layer. In this work, electrode quenching control was realized via incorporating Au NPs into PEDOT:PSS. As a result, the CsPbBr3 PeLEDs realized an improvement in maximum luminescence ranging from ˜2348 to ˜7660 cd m-2 (˜226% enhancement) and current efficiency from 1.65 to 3.08 cd A-1 (˜86% enhancement). Such substantial enhancement of the electroluminescent performance can be attributed to effective electrode quenching control at the PEDOT:PSS/CsPbBr3 perovskite interface via the combined effects of local surface plasma resonance coupling and enhanced hole transportation in the PEDOT:PSS layer by Au nanoparticles.

  1. [Screening based on response surface methodology of multi-fractions traditional Chinese medicine with anti-influenza virus neuraminidase activity: take shuanghuanglian injection as an example].

    Science.gov (United States)

    Qiu, Ling-Ling; Chen, Long-Hu; Yan, Dan; Zhang, Ping; Tan, Man-Rong; Li, Zheng-Ming; Xiao, Xiao-He

    2012-04-01

    This study aimed to establish a novel method to screen out the combined components of multi-fractions traditional Chinese medicine (TCM), so that the internal relationship between multi-ingredients could be objectively assessed and the proportioning ratio could be optimized. Taking antiviral effect on neuraminidase activity of influenza virus as the evaluating indicator and using Box-Behnken response surface methodology, the main effective ingredients of Shuanghuanglian injection (SHL) were screened. Meanwhile, the relationship between active ingredients was discussed. Taking SHL as a comparison, the optimum proportioning ratio was predicted. The results indicated that chlorogenic acid, cryptochlorogenic acid, caffeic acid and baicalin have comparatively strong antiviral activity against influenza virus. Moreover, antagonistic action existed between chlorogenic acid and cryptochlorogenic acid, whereas synergistic action between caffeic acid and other components. The optimum proportioning ratio resulted from fitted model is: chlorogenic acid, cryptochlorogenic acid, caffeic acid and baicalin (107 microg x mL(-1) : 279 microg x mL(-1) : 7.99 microg x mL(-1) : 92 microg x mL(-1)). The antiviral activity of the recombined components is stronger than that of SHL, which was consistent with the experiment results (P < 0.05). Box-Behnken response surface methodology has the advantages of general-screening, high-performance and accurate-prediction etc, which is appropriate for screening the combined components of multi-fractions TCM and the optimization of the proportioning ratio. The proposed method can serve as a technological support for the development of modern multi-fractions TCM.

  2. Liquid Microjunction Surface Sampling Probe Electrospray Mass Spectrometry for Detection of Drugs and Metabolites in Thin Tissue Sections

    Energy Technology Data Exchange (ETDEWEB)

    Van Berkel, Gary J [ORNL; Kertesz, Vilmos [ORNL; Koeplinger, Kenneth A. [Merck Research Laboratories; Vavek, Marissa [Merck Research Laboratories; Kong, Ah-Ng Tony [Rutgers University

    2008-01-01

    A self-aspirating, liquid micro-junction surface sampling probe/electrospray emitter mass spectrometry system was demonstrated for use in the direct analysis of spotted and dosed drugs and their metabolites in thin tissue sections. Proof-of-principle sampling and analysis directly from tissue without the need for sample preparation was demonstrated first by raster scanning a region on a section of rat liver onto which reserpine was spotted. The mass spectral signal from selected reaction monitoring was used to develop a chemical image of the spotted drug on the tissue. The probe was also used to selectively spot sample areas of sagittal whole mouse body tissue sections that had been dosed orally (90 mg/kg) with R,S-sulforaphane 3 hrs prior to sacrifice. Sulforaphane and its glutathione and N-acetyl cysteine conjugates were monitored with selected reaction monitoring and detected in the stomach and various other tissues from the dosed mouse. No signal for these species was observed in the tissue from a control mouse. The same dosed tissue section was used to illustrate the possibility of obtaining a line scan across the whole body section. In total these results illustrate the potential for rapid screening of the distribution of drugs and metabolites in tissue sections with the micro-liquid junction surface sampling probe/electrospray mass spectrometry approach.

  3. Discussion on the Heat and Mass Transfer Model on the Pool Surface

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Soon-Joon; Choo, Yeon-Jun [FNC Tech., Yongin (Korea, Republic of); Ha, Sang-Jun [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Heat transfer on the pool surface involves the evaporation and condensation of steam in the presence of non-condensable gas. It is a kind of inter-phase heat transfer. This phenomenon has been regarded as less important on the thermal hydraulic behaviors such as pressure, temperature, hydrogen distribution, and so on in the nuclear reactor containment building. As a matter of fact, several RAIs (requests for additional information) during the licensing review of the developed CAP have been presented. And early in 2000s the steam condensation on the water surface of IRWST was a concern of APR1400 design. Such an increased concern is believed because it is a newly adopted system. This study discusses the pool surface heat transfer by reviewing the models of several well-known containment analysis codes, and conducting the sensitivities. This study discussed the pool surface heat transfer. The related models of CAP, GOTHIC, CONTEMPT-LT, and CONTEMPT4 were compared. The sensitivity of heat transfer coefficient for SKN3 and 4 using conventional code CONTEMPT-LT/028-A showed little effect. And the sensitivity of relative humidity and heat transfer area for latent heat transfer shows that CAP locates between GOTHIC and CONTEMPT4/MOD. The sensitivity for sensible heat transfer also shows similar trend. Conclusively, current CAP model of pool surface heat transfer has no fatal defect.

  4. Discussion on the Heat and Mass Transfer Model on the Pool Surface

    International Nuclear Information System (INIS)

    Hong, Soon-Joon; Choo, Yeon-Jun; Ha, Sang-Jun

    2016-01-01

    Heat transfer on the pool surface involves the evaporation and condensation of steam in the presence of non-condensable gas. It is a kind of inter-phase heat transfer. This phenomenon has been regarded as less important on the thermal hydraulic behaviors such as pressure, temperature, hydrogen distribution, and so on in the nuclear reactor containment building. As a matter of fact, several RAIs (requests for additional information) during the licensing review of the developed CAP have been presented. And early in 2000s the steam condensation on the water surface of IRWST was a concern of APR1400 design. Such an increased concern is believed because it is a newly adopted system. This study discusses the pool surface heat transfer by reviewing the models of several well-known containment analysis codes, and conducting the sensitivities. This study discussed the pool surface heat transfer. The related models of CAP, GOTHIC, CONTEMPT-LT, and CONTEMPT4 were compared. The sensitivity of heat transfer coefficient for SKN3 and 4 using conventional code CONTEMPT-LT/028-A showed little effect. And the sensitivity of relative humidity and heat transfer area for latent heat transfer shows that CAP locates between GOTHIC and CONTEMPT4/MOD. The sensitivity for sensible heat transfer also shows similar trend. Conclusively, current CAP model of pool surface heat transfer has no fatal defect

  5. A desk study of surface diffusion and mass transport in clay

    International Nuclear Information System (INIS)

    Cook, A.J.

    1988-09-01

    The concept of a geological barrier to radionuclide migration from theoretical radioactive waste repositories has drawn attention to the physico-chemical properties of clays, which are traditionally regarded as retarding media. This report addresses the different mechanisms of transport of radionuclides through clay and in particular focuses on the surface diffusion movement of sorbed cations. The relative contributory importance of the different transport mechanisms is governed by the pore size distributions and interconnections within the clay fabric. Surface diffusion data in the literature have been from experiments using compacted montmorillonite and biotite gneiss. A possible programme of laboratory work is outlined, based on diffusion experiments, which describes the way of measuring the effect of surface diffusion more accurately in clays, mudstones and shales. (author)

  6. Investigation of silicate surface chemistry and reaction mechanisms associated with mass transport in geologic media

    International Nuclear Information System (INIS)

    White, A.F.; Perry, D.L.

    1982-01-01

    The concentration and rate of transport of radionuclides through geologic media can be strongly influenced by the extent of sorption on aquifer surfaces. Over time intervals relevant to such transport processes, rock and mineral surfaces cannot be considered as inert, unreactive substrates but rather as groundwater/solidphase interfaces which are commonly in a state of natural or artificially induced disequilibrium. The goal of the present research is to define experimentally the type of water/rock interactions that will influence surface chemistry and hence sorption characteristics and capacities of natural aquifers. As wide a range of silicate minerals as possible was selected for study to represent rock-forming minerals in basalt, tuff, and granite. The minerals include K-feldspar, plagioclase feldspar, olivine, hornblende, biotite, and volcanic glass

  7. Role of Rock Mass Fabric and Faulting in the Development of Block Caving Induced Surface Subsidence

    Science.gov (United States)

    Vyazmensky, Alexander; Elmo, Davide; Stead, Douglas

    2010-09-01

    Extraction of a large volume of ore during block caving can lead to the formation of significant surface subsidence. Current knowledge of the mechanisms that control subsidence development is limited as are our subsidence prediction capabilities. Mining experience suggests that, among other contributing factors, geological structures play a particularly important role in subsidence development. A conceptual modeling study has been undertaken to evaluate the significance of geological structure on surface subsidence. A hybrid finite/discrete element technique incorporating a coupled elasto-plastic fracture mechanics constitutive criterion is adopted; this allows physically realistic modeling of block caving through simulation of the transition from a continuum to a discontinuum. Numerical experiments presented emphasize the importance of joint orientation and fault location on mechanisms of subsidence development and the governing role of geological structure in defining the degree of surface subsidence asymmetry.

  8. A comparison of molding procedures - Contact, injection and vacuum injection

    Science.gov (United States)

    Cathiard, G.

    1980-06-01

    The technical and economic aspects of the contact, injection and vacuum injection molding of reinforced plastic components are compared for the example of a tractor roof with a gel-coated surface. Consideration is given to the possibility of reinforcement, number of smooth faces, condition of the gel-coated surface, reliability, and labor and workplace requirements of the three processes, and advantages of molding between the mold and a countermold in smooth faces, reliability, labor requirements, working surface and industrial hygiene are pointed out. The times and labor requirements of each step in the molding cycles are examined, and material requirements and yields, investment costs, amortization and product cost prices of the processes are compared. It is concluded that, for the specific component examined, the processes of vacuum injection and injection molding appear very interesting, with injection molding processes resulting in lower cost prices than contact molding for any production volume.

  9. Chemical analysis of surfaces by resonance ionization mass spectroscopy associated to ionic pulverization

    International Nuclear Information System (INIS)

    Kern, P.

    1995-01-01

    This work shows that if resonance ionization mass spectroscopy was first applied in isotopic separation, it's also an analyzing method adapted to the study of semi-conductor materials and thin foils. We have improved this technic: a neodymium laser coupled with a dye laser, a new argon ions gun, a gallium ions gun and a new collection optic for the secondary ions quadrupole spectrometer to allow quantitative and selective measurements. (S.G.). 84 refs

  10. Estimation of the Greenland ice sheet surface mass balance for the 20th and 21st centuries

    Directory of Open Access Journals (Sweden)

    X. Fettweis

    2008-09-01

    Full Text Available Results from a regional climate simulation (1970–2006 over the Greenland ice sheet (GrIS reveals that more than 97% of the interannual variability of the modelled Surface Mass Balance (SMB can be explained by the GrIS summer temperature anomaly and the GrIS annual precipitation anomaly. This multiple regression is then used to empirically estimate the GrIS SMB since 1900 from climatological time series. The projected SMB changes in the 21st century are investigated with the set of simulations performed with atmosphere-ocean general circulation models (AOGCMs of the Fourth Assessment Report of the Intergovernmental Panel on Climate Change (IPCC AR4. These estimates show that the high surface mass loss rates of recent years are not unprecedented in the GrIS history of the last hundred years. The minimum SMB rate seems to have occurred earlier in the 1930s and corresponds to a zero SMB rate. The AOGCMs project that the SMB rate of the 1930s would be common at the end of 2100. The temperature would be higher than in the 1930s but the increase of accumulation in the 21st century would partly offset the acceleration of surface melt due to the temperature increase. However, these assumptions are based on an empirical multiple regression only validated for recent/current climatic conditions, and the accuracy and time homogeneity of the data sets and AOGCM results used in these estimations constitute a large uncertainty.

  11. On Deriving Requirements for the Surface Mass Balance forcing of a Greenland Ice Sheet Model using Uncertainty Analyses

    Science.gov (United States)

    Schlegel, N.; Larour, E. Y.; Box, J. E.

    2015-12-01

    During July of 2012, the percentage of the Greenland surface exposed to melt was the largest in recorded history. And, even though evidence of increased melt rates had been captured by remote sensing observations throughout the last decade, this particular event took the community by surprise. How Greenland ice flow will respond to such an event or to increased frequencies of extreme melt events in the future is unclear, as it requires detailed comprehension of Greenland surface climate and the ice sheet's sensitivity to associated uncertainties. With established uncertainty quantification (UQ) tools embedded within the Ice Sheet System Model (ISSM), we conduct decadal-scale forward modeling experiments to 1) quantify the spatial resolution needed to effectively force surface mass balance (SMB) in various regions of the ice sheet and 2) determine the dynamic response of Greenland outlet glaciers to variations in SMB. First, we perform sensitivity analyses to determine how perturbations in SMB affect model output; results allow us to investigate the locations where variations most significantly affect ice flow, and on what spatial scales. Next, we apply Monte-Carlo style sampling analyses to determine how errors in SMB propagate through the model as uncertainties in estimates of Greenland ice discharge and regional mass balance. This work is performed at the California Institute of Technology's Jet Propulsion Laboratory under a contract with the National Aeronautics and Space Administration's Cryosphere Program.

  12. High-resolution mass spectrometry for the analysis of interfacial kinetics of organic surface reactions

    NARCIS (Netherlands)

    Sen, Rickdeb

    2017-01-01

    In this thesis, XPS and DART–HRMS have been used in close conjugation to supplement each other, since the latter is a relatively new addition to surface chemist’s repertoire that – after development – needed a firm comparison to build up a reputation of its own. The strength of our approach has

  13. Allometric relationships for surface area and dry mass of young Norway spruce aboveground organs

    Czech Academy of Sciences Publication Activity Database

    Pokorný, Radek; Tomášková, Ivana

    53 2007, č. 12 (2007), s. 548-554 ISSN 1212-4834 R&D Projects: GA MŽP(CZ) SP/2D1/93/07 Institutional research plan: CEZ:AV0Z60870520 Keywords : allometry * biomass, * Picea abies * sapwood * surface area Subject RIV: GK - Forestry

  14. Gemini NIFS survey of feeding and feedback processes in nearby active galaxies - II. The sample and surface mass density profiles

    Science.gov (United States)

    Riffel, R. A.; Storchi-Bergmann, T.; Riffel, R.; Davies, R.; Bianchin, M.; Diniz, M. R.; Schönell, A. J.; Burtscher, L.; Crenshaw, M.; Fischer, T. C.; Dahmer-Hahn, L. G.; Dametto, N. Z.; Rosario, D.

    2018-02-01

    We present and characterize a sample of 20 nearby Seyfert galaxies selected for having BAT 14-195 keV luminosities LX ≥ 1041.5 erg s-1, redshift z ≤ 0.015, being accessible for observations with the Gemini Near-Infrared Field Spectrograph (NIFS) and showing extended [O III]λ5007 emission. Our goal is to study Active Galactic Nucleus (AGN) feeding and feedback processes from near-infrared integral-field spectra, which include both ionized (H II) and hot molecular (H2) emission. This sample is complemented by other nine Seyfert galaxies previously observed with NIFS. We show that the host galaxy properties (absolute magnitudes MB, MH, central stellar velocity dispersion and axial ratio) show a similar distribution to those of the 69 BAT AGN. For the 20 galaxies already observed, we present surface mass density (Σ) profiles for H II and H2 in their inner ˜500 pc, showing that H II emission presents a steeper radial gradient than H2. This can be attributed to the different excitation mechanisms: ionization by AGN radiation for H II and heating by X-rays for H2. The mean surface mass densities are in the range (0.2 ≤ ΣH II ≤ 35.9) M⊙ pc-2, and (0.2 ≤ ΣH2 ≤ 13.9)× 10-3 M⊙ pc-2, while the ratios between the H II and H2 masses range between ˜200 and 8000. The sample presented here will be used in future papers to map AGN gas excitation and kinematics, providing a census of the mass inflow and outflow rates and power as well as their relation with the AGN luminosity.

  15. The effect of TiO2 surface on the electron injection efficiency in PbS quantum dot solar cells: a first-principles study.

    NARCIS (Netherlands)

    Azpiroz, Jon M.; Ugalde, Jesus M.; Etgar, Lioz; Infante, Ivan; De Angelis, Filippo

    2015-01-01

    We present a density functional theory (DFT) study aimed at understanding the injection and recombination processes that occur at the interface between PbS QDs and TiO2 oxide nanoparticles with different morphologies. The calculated injection rates fall in the picosecond timescale in good agreement

  16. On-Line Derivatization Gas Chromatography Ion Trap Mass Spectrometry for Determination of Endocrine Disruptors in Surface Water

    Energy Technology Data Exchange (ETDEWEB)

    Tzing, Shin-Hwa; Chang, Jia-Yaw; Ling, Yong-Chien

    2004-03-31

    A method has been developed for the determination of endocrine disruptors (EDs) (containing hydroxyl groups) in surface water from different sources. The surface water samples from different sites including school and local dormitory sewage effluents, lake water and river water were collected and analyzed. In this method, the pretreated sample is directly analyzed by GC-MS using on-line derivatization, where tetramethylammonium hydroxide (TMA-OH) was used as the derivatizing agent. Use of large-volume direct sample introduction (DSI) and co-injection of the sample and TMAOH avoids external contaminations as observed in conventional derivatization protocols. Additionally, the use of chemical ionization (CI) and CI-MS/MS could enable detection of EDs at lower concentrations and reduce the matrices' interference thereby enhancing detection sensitivity of EDs for quantification. In this work, the use of dichloromethane as CI reagent for EDs is reported for the first time and could detect EDs to concentrations as low as 0.5 pg/mL. The recovery ranged from 74 to 112 % and the relative standard derivations for replicate analyses ranged from 5 to 17 %. We hope that this method will be applicable for routine analysis of EDs with hydroxyl functional groups.

  17. A METHOD OF LOADING UNIT FORMATION TAKING INTO ACCOUNT MASS, LOAD-BEARING STRENGTH AND SURFACES OF PACKING UNITS

    Directory of Open Access Journals (Sweden)

    Kamil POPIELA

    2017-09-01

    Full Text Available The problem of loading unit formation is computationally complex in nature. This article presents a heuristic algorithm of forming unit loads, which can be applied to unit load arrangement on unit load devices. This method accounts for dimensional, mass and load-bearing strength of loading units and loading devices. Moreover, the rotation of packages about a 90° vertical axis has been made possible. In this algorithm, the bearing surface of each packing unit is entirely supported. This guarantees the stability of additional unit load layers. A sample calculation of the arrangement of 30-unit loads is presented in this article.

  18. The interaction between endopolygalacturonase from Fusarium moniliforme and PGIP from Phaseolus Vulgaris studied by surface plasmon resonance and mass spectrometry

    DEFF Research Database (Denmark)

    Mattei, B; Cervone, F; Roepstorff, Peter

    2001-01-01

    A combination of surface plasmon resonance (SPR) and matrix-assisted laser-desorptionionization- time-of-flight mass spectrometry (MALDI-TOF-MS) was used to study the interaction between endopolygalacturonase (PG) from Fusarium moniliforme and a polygalacturonase-inhibiting protein (PGIP) from...... Phaseolus vulgaris. PG hydrolyses the homogalacturonan of the plant cell wall and is considered an important pathogenicity factor of many fungi. PGIP is a specific inhibitor of fungal PGs and is thought to be involved in plant defence against phytopathogenic fungi. SPR was used either to study the effect...

  19. Recovery of surface mass redistribution from a joint inversion of GPS and GRACE data - A methodology and results from the Australian and other continents

    Science.gov (United States)

    Han, S. C.; Tangdamrongsub, N.; Razeghi, S. M.

    2017-12-01

    We present a methodology to invert a regional set of vertical displacement data from Global Positioning System (GPS) to determine surface mass redistribution. It is assumed that GPS deformation is a result of the Earth's elastic response to the surface mass load of hydrology, atmosphere, and ocean. The identical assumption is made when global geopotential change data from Gravity Recovery And Climate Experiment (GRACE) are used to determine surface mass changes. We developed an algorithm to estimate the spectral information of displacements from "regional" GPS data through regional spherical (Slepian) basis functions and apply the load Love numbers to estimate the mass load. We rigorously examine all systematic errors caused by various truncations (spherical harmonic series and Slepian series) and the smoothing constraint applied to the GPS-only inversion. We demonstrate the technique by processing 16 years of daily vertical motions determined from 114 GPS stations in Australia. The GPS inverted surface mass changes are validated against GRACE data, atmosphere and ocean models, and a land surface model. Seasonal and inter-annual terrestrial mass variations from GPS are in good agreement with GRACE data and the water storage models. The GPS recovery compares better with the water storage model around the smaller coastal basins of Australia than two different GRACE solutions. The sub-monthly mass changes from GPS provide meaningful results agreeing with atmospheric mass changes in central Australia. Finally, we integrate GPS data from different continents with GRACE in the least-square normal equations and solve for the global surface mass changes by jointly inverting GPS and GRACE data. We present the results of surface mass changes from the GPS-only inversion and from the joint GPS-GRACE inversion.

  20. FI/SI on-line solvent extraction/back extraction preconcentration coupled to direct injection nebulization inductively coupled plasma mass spectrometry for determination of copper and lead

    DEFF Research Database (Denmark)

    Wang, Jianhua; Hansen, Elo Harald

    2002-01-01

    An automated sequential injection on-line preconcentration procedure for determination of trace levels of copper and lead via solvent extraction/back extraction coupled to ICP-MS is described. In citrate buffer of pH 3, neutral complexes between the analytes and the chelating reagent, ammonium...... acid containing Pd(II) ions as stripping agent, thereby facilitating a rapid metal exchange reaction with the APDC ligand and transfer of the analytes back into the aqueous phase. The aqueous phase is separated in a second dual-conical gravitational phase separator, and 30 mul is entrapped in a sample...

  1. Planar Functionalized Surfaces for Direct Immunoaffinity Desorption/Ionization Mass Spectrometry

    Czech Academy of Sciences Publication Activity Database

    Pompach, Petr; Kavan, Daniel; Benada, Oldřich; Růžička, V.; Volný, M.; Novák, Petr

    2016-01-01

    Roč. 62, č. 1 (2016), s. 270-278 ISSN 0009-9147 R&D Projects: GA MŠk LO1509; GA MŠk(CZ) EE2.3.30.0003; GA MŠk(CZ) ED1.1.00/02.0109 Institutional support: RVO:61388971 Keywords : TREATED METAL-SURFACE * IN-SITU ENRICHMENT * ELECTROSPRAY DEPOSITION Subject RIV: CE - Biochemistry Impact factor: 8.008, year: 2016

  2. Open charcoal chamber method for mass measurements of radon exhalation rate from soil surface

    International Nuclear Information System (INIS)

    Tsapalov, Andrey; Kovler, Konstantin; Miklyaev, Peter

    2016-01-01

    Radon exhalation rate from the soil surface can serve as an important criterion in the evaluation of radon hazard of the land. Recently published international standard ISO 11665-7 (2012) is based on the accumulation of radon gas in a closed container. At the same time since 1998 in Russia, as a part of engineering and environmental studies for the construction, radon flux measurements are made using an open charcoal chamber for a sampling duration of 3–5 h. This method has a well-defined metrological justification and was tested in both favorable and unfavorable conditions. The article describes the characteristics of the method, as well as the means of sampling and measurement of the activity of radon absorbed. The results of the metrological study suggest that regardless of the sampling conditions (weather, the mechanism and rate of radon transport in the soil, soil properties and conditions), uncertainty of method does not exceed 20%, while the combined standard uncertainty of radon exhalation rate measured from the soil surface does not exceed 30%. The results of the daily measurements of radon exhalation rate from the soil surface at the experimental site during one year are reported. - Highlights: • Radon exhalation rate from the soil surface area of 32 cm 2 can be measured at level of 10 mBq/(m 2 s) at the uncertainty ≤30%. • The method has a metrological justification. • No need to consider climate conditions, soil properties and conditions, mechanism and rate of radon transport in the soil.

  3. Mathematical analysis of intermittent gas injection model in oil production

    Science.gov (United States)

    Tasmi, Silvya, D. R.; Pudjo, S.; Leksono, M.; Edy, S.

    2016-02-01

    Intermittent gas injection is a method to help oil production process. Gas is injected through choke in surface and then gas into tubing. Gas forms three areas in tubing: gas column area, film area and slug area. Gas column is used to propel slug area until surface. A mathematical model of intermittent gas injection is developed in gas column area, film area and slug area. Model is expanding based on mass and momentum conservation. Using assume film thickness constant in tubing, model has been developed by Tasmi et. al. [14]. Model consists of 10 ordinary differential equations. In this paper, assumption of pressure in gas column is uniform. Model consist of 9 ordinary differential equations. Connection of several variables can be obtained from this model. Therefore, dynamics of all variables that affect to intermittent gas lift process can be seen from four equations. To study the behavior of variables can be analyzed numerically and mathematically. In this paper, simple mathematically analysis approach is used to study behavior of the variables. Variables that affect to intermittent gas injection are pressure in upstream valve and in gas column. Pressure in upstream valve will decrease when gas mass in valve greater than gas mass in choke. Dynamic of the pressure in the gas column will decrease and increase depending on pressure in upstream valve.

  4. Ambient ionization mass spectrometry imaging for characterizing plant-microbe interactions using liquid extraction surface analysis (LESA)

    Science.gov (United States)

    Chu, R. K.; Anderton, C.; Weston, D. J.; Carrell, A. A.; Paša-Tolić, L.; Veličković, D.; Tfaily, M.

    2017-12-01

    The rhizosphere consists of a diverse community of plants, bacteria and fungi that are interacting with each other and with complex soil matrix they occupy. By studying the chemical signaling and processes that occur within this dynamic microenvironment, we will further our understanding of the symbiotic and competitive interaction within microbial communities. Field studies and bulk analyses shed light on the mechanisms by which environmental perturbations alter carbon and nitrogen cycling, but what is less clear are the intra- and interspecies molecular transformations and transactions between the different constituents within the rhizosphere. Chemical imaging by liquid extraction surface analysis mass spectrometry (LESA-MS) is a highly sensitive technique capable of providing both spatial and molecular information. Here, we examined the chemical interactions among a tripartite system of peat moss (Sphagnum fallax), cyanobacteria (Nostoc muscorium), and fungus (Trizdiaspa). We coupled LESA source to both a 15 Tesla Fourier transform ion cyclotron resonance mass spectrometer (FTICR-MS), for ultrahigh mass resolution and mass accuracy results, and a Thermo Velos-LTQ mass spectrometer, for tandem MS of selected molecules to increase confidence in molecular identifications. With LESA-MS approach we spatially probed the tripartite interactions and isolated cultures using a coordinate system that can be mapped back and overlaid onto the original image. Using this method, we mapped an array of metabolic distributions within the model sphagnum microbiome. For instance, we identified carbendazim, an anti-fungal agent, distributed within the interaction zone between the bacteria and fungi, while glyceropcholine and sucrose were localized within the sphagnum and fungus interaction zone. Further analysis will look into larger metabolites, lipids, and small proteins.

  5. Comparative analysis of the uropathogenic Escherichia coli surface proteome by tandem mass-spectrometry of artificially induced outer membrane vesicles.

    Science.gov (United States)

    Wurpel, Daniël J; Moriel, Danilo G; Totsika, Makrina; Easton, Donna M; Schembri, Mark A

    2015-02-06

    Uropathogenic Escherichia coli (UPEC) are the major cause of urinary tract infections. For successful colonisation of the urinary tract, UPEC employ multiple surface-exposed or secreted virulence factors, including adhesins and iron uptake systems. Whilst individual UPEC strains and their virulence factors have been the focus of extensive research, there have been no outer membrane (OM) proteomic studies based on large clinical UPEC collections, primarily due to limitations of traditional methods. In this study, a high-throughput method based on tandem mass-spectrometry of EDTA heat-induced outer membrane vesicles (OMVs) was developed for the characterisation of the UPEC surface-associated proteome. The method was applied to compare the OM proteome of fifty-four UPEC isolates, resulting in the identification of 8789 proteins, consisting of 619 unique proteins, which were subsequently interrogated for their subcellular origin, prevalence and homology to characterised virulence factors. Multiple distinct virulence-associated proteins were identified, including two novel putative iron uptake proteins, an uncharacterised type of chaperone-usher fimbriae and various highly prevalent hypothetical proteins. Our results give fundamental insight into the physiology of UPEC and provide a framework for understanding the composition of the UPEC OM proteome. In this study a high-throughput method based on tandem mass-spectrometry of EDTA heat-induced outer membrane vesicles was used to define the outer membrane proteome of a large uropathogenic E. coli (UPEC) collection. Our results provide an inventory of proteins expressed on the surface of UPEC, and provide a framework for understanding the composition of the UPEC OM proteome. The method enables the rapid characterisation of the E. coli surface proteome and could easily be applied to the large-scale outer membrane protein profiling of other Gram-negative bacteria. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Molecular-scale model for the mass density of electrolyte solutions bound by clay surfaces: application to bentonites.

    Science.gov (United States)

    Gonçalvès, J; Rousseau-Gueutin, P

    2008-04-15

    A model to simulate the density of solutions adsorbed onto clay mineral surfaces is proposed. In this model, the alteration of the ionic distribution caused by the electric field associated with the surface charge of clay platelets is accounted for using an electrical triple-layer model with an overlapping diffuse layer. The combined effects of ion hydration and the electric field on the structure of water are introduced through their influence on the partial molar volume of water. This model, applied to Na-montmorillonite, simulates the distribution of the interplatelet solution density as a function of the distance to the mineral surface. High densities in the direct vicinity of the surface and slightly lower density (a few percent) than the normal density in the diffuse layer are obtained. These results show good consistency with the available data on bentonite and with the densities that can be inferred from molecular dynamics simulations. This model shows that the interplatelet distance plays an important role in the distribution of the mass density of the solution in the pore space of clay rocks.

  7. Pesticide residue determination in surface waters by stir bar sorptive extraction and liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Giordano, A; Fernández-Franzón, M; Ruiz, M J; Font, G; Picó, Y

    2009-03-01

    In this stir bar sorptive extraction (SBSE) method, 16 pesticides were extracted from surface water samples by sorption onto 1 mm polydimethylsiloxane layer coated on a 10-mm-length stir bar magnet. After liquid desorption of the analytes with 1 ml of methanol, the detection was performed on a liquid chromatography-tandem mass spectrometry with a triple quadrupole (QqQ) analyzer using selected reaction monitoring mode via electrospray ionization. Parameters affecting SBSE operation, including sample volume, salt addition, extraction time, stirring rate, and desorption conditions, have been evaluated. The optimized SBSE method required two 50 ml aliquots of surface water samples, one aliquot was added of 30% NaCl and stirred at 900 rpm during 1 h for testing five pesticides with log K(o/w) 3. The method was validated in spiked surface water samples at limits of quantifications (LOQs) and ten times the LOQs showing recoveries Albufera Lake and surrounding channels, showing that SBSE is a powerful tool for routine control analysis of pesticide residues in surface water.

  8. A Comparison of Tissue Spray and Lipid Extract Direct Injection Electrospray Ionization Mass Spectrometry for the Differentiation of Eutopic and Ectopic Endometrial Tissues

    Science.gov (United States)

    Chagovets, Vitaliy; Wang, Zhihao; Kononikhin, Alexey; Starodubtseva, Natalia; Borisova, Anna; Salimova, Dinara; Popov, Igor; Kozachenko, Andrey; Chingin, Konstantin; Chen, Huanwen; Frankevich, Vladimir; Adamyan, Leila; Sukhikh, Gennady

    2018-02-01

    Recent research revealed that tissue spray mass spectrometry enables rapid molecular profiling of biological tissues, which is of great importance for the search of disease biomarkers as well as for online surgery control. However, the payback for the high speed of analysis in tissue spray analysis is the generally lower chemical sensitivity compared with the traditional approach based on the offline chemical extraction and electrospray ionization mass spectrometry detection. In this study, high resolution mass spectrometry analysis of endometrium tissues of different localizations obtained using direct tissue spray mass spectrometry in positive ion mode is compared with the results of electrospray ionization analysis of lipid extracts. Identified features in both cases belong to three lipid classes: phosphatidylcholines, phosphoethanolamines, and sphingomyelins. Lipids coverage is validated by hydrophilic interaction liquid chromatography with mass spectrometry of lipid extracts. Multivariate analysis of data from both methods reveals satisfactory differentiation of eutopic and ectopic endometrium tissues. Overall, our results indicate that the chemical information provided by tissue spray ionization is sufficient to allow differentiation of endometrial tissues by localization with similar reliability but higher speed than in the traditional approach relying on offline extraction.

  9. A Comparison of Tissue Spray and Lipid Extract Direct Injection Electrospray Ionization Mass Spectrometry for the Differentiation of Eutopic and Ectopic Endometrial Tissues

    Science.gov (United States)

    Chagovets, Vitaliy; Wang, Zhihao; Kononikhin, Alexey; Starodubtseva, Natalia; Borisova, Anna; Salimova, Dinara; Popov, Igor; Kozachenko, Andrey; Chingin, Konstantin; Chen, Huanwen; Frankevich, Vladimir; Adamyan, Leila; Sukhikh, Gennady

    2017-09-01

    Recent research revealed that tissue spray mass spectrometry enables rapid molecular profiling of biological tissues, which is of great importance for the search of disease biomarkers as well as for online surgery control. However, the payback for the high speed of analysis in tissue spray analysis is the generally lower chemical sensitivity compared with the traditional approach based on the offline chemical extraction and electrospray ionization mass spectrometry detection. In this study, high resolution mass spectrometry analysis of endometrium tissues of different localizations obtained using direct tissue spray mass spectrometry in positive ion mode is compared with the results of electrospray ionization analysis of lipid extracts. Identified features in both cases belong to three lipid classes: phosphatidylcholines, phosphoethanolamines, and sphingomyelins. Lipids coverage is validated by hydrophilic interaction liquid chromatography with mass spectrometry of lipid extracts. Multivariate analysis of data from both methods reveals satisfactory differentiation of eutopic and ectopic endometrium tissues. Overall, our results indicate that the chemical information provided by tissue spray ionization is sufficient to allow differentiation of endometrial tissues by localization with similar reliability but higher speed than in the traditional approach relying on offline extraction. [Figure not available: see fulltext.

  10. Chemical profiling of Re-Du-Ning injection by ultra-performance liquid chromatography coupled with electrospray ionization tandem quadrupole time-of-flight mass spectrometry through the screening of diagnostic Ions in MS(E mode.

    Directory of Open Access Journals (Sweden)

    Haibo Li

    Full Text Available The broad applications and mechanism explorations of traditional Chinese medicine prescriptions (TCMPs require a clear understanding of TCMP chemical constituents. In the present study, we describe an efficient and universally applicable analytical approach based on ultra-performance liquid chromatography coupled to electrospray ionization tandem quadrupole time-of-flight mass spectrometry (UPLC-ESI-Q/TOF-MS with the MS(E ((E denotes collision energy data acquisition mode, which allowed the rapid separation and reliable determination of TCMP chemical constituents. By monitoring diagnostic ions in the high energy function of MS(E, target peaks of analogous compounds in TCMPs could be rapidly screened and identified. "Re-Du-Ning" injection (RDN, a eutherapeutic traditional Chinese medicine injection (TCMI that has been widely used to reduce fever caused by viral infections in clinical practice, was studied as an example. In total, 90 compounds, including five new iridoids and one new sesquiterpene, were identified or tentatively characterized by accurate mass measurements within 5 ppm error. This analysis was accompanied by MS fragmentation and reference standard comparison analyses. Furthermore, the herbal sources of these compounds were unambiguously confirmed by comparing the extracted ion chromatograms (EICs of RDN and ingredient herbal extracts. Our work provides a certain foundation for further studies of RDN. Moreover, the analytical approach developed herein has proven to be generally applicable for profiling the chemical constituents in TCMPs and other complicated mixtures.

  11. Chemical Profiling of Re-Du-Ning Injection by Ultra-Performance Liquid Chromatography Coupled with Electrospray Ionization Tandem Quadrupole Time-of-Flight Mass Spectrometry through the Screening of Diagnostic Ions in MSE Mode

    Science.gov (United States)

    Wang, Zhenzhong; Geng, Jianliang; Dai, Yi; Xiao, Wei; Yao, Xinsheng

    2015-01-01

    The broad applications and mechanism explorations of traditional Chinese medicine prescriptions (TCMPs) require a clear understanding of TCMP chemical constituents. In the present study, we describe an efficient and universally applicable analytical approach based on ultra-performance liquid chromatography coupled to electrospray ionization tandem quadrupole time-of-flight mass spectrometry (UPLC-ESI-Q/TOF-MS) with the MSE (E denotes collision energy) data acquisition mode, which allowed the rapid separation and reliable determination of TCMP chemical constituents. By monitoring diagnostic ions in the high energy function of MSE, target peaks of analogous compounds in TCMPs could be rapidly screened and identified. “Re-Du-Ning” injection (RDN), a eutherapeutic traditional Chinese medicine injection (TCMI) that has been widely used to reduce fever caused by viral infections in clinical practice, was studied as an example. In total, 90 compounds, including five new iridoids and one new sesquiterpene, were identified or tentatively characterized by accurate mass measurements within 5 ppm error. This analysis was accompanied by MS fragmentation and reference standard comparison analyses. Furthermore, the herbal sources of these compounds were unambiguously confirmed by comparing the extracted ion chromatograms (EICs) of RDN and ingredient herbal extracts. Our work provides a certain foundation for further studies of RDN. Moreover, the analytical approach developed herein has proven to be generally applicable for profiling the chemical constituents in TCMPs and other complicated mixtures. PMID:25875968

  12. Response Surface Analysis and Nonlinear Optimization Algorithm for Maximization of Clinical Drug Performance: Application to Extended-Release and Long-Acting Injectable Paliperidone.

    Science.gov (United States)

    Gomeni, Roberto; Bressolle-Gomeni, Françoise; Fava, Maurizio

    2016-10-01

    Model-based approach is recognized as a tool to make drug development more productive and to better support regulatory and therapeutic decisions. The objective of this study was to develop a novel model-based methodology based on the response surface analysis and a nonlinear optimizer algorithm to maximize the clinical performances of drug treatments. The treatment response was described using a drug-disease model accounting for multiple components such as the dosage regimen, the pharmacokinetic characteristics of a drug (including the mechanism and the rate of drug delivery), and the exposure-response relationship. Then, the clinical benefit of a treatment was defined as a function of the diseases and the clinical endpoints and was estimated as a function of the target pharmacodynamic endpoints used to evaluate the treatment effect. A case study is presented to illustrate how the treatment performances of paliperidone extended release (ER) and paliperidone long-acting injectable (LAI) can be improved. A convolution-based approach was used to characterize the pharmacokinetics of ER and LAI paliperidone. The drug delivery properties and the dosage regimen maximizing the clinical benefit (defined as the target level of D2 receptor occupancy) were estimated using a nonlinear optimizer. The results of the analysis indicated that a substantial improvement in clinical benefit (from 15% to 27% for the optimization of the in vivo release and from ∼30% to ∼70% for the optimization of dosage regimen) was obtained when optimal strategies were deployed either for optimizing the in vivo drug delivery properties of ER formulations or for optimizing the dosage regimen of LAI formulations. © 2016, The American College of Clinical Pharmacology.

  13. Direct Surface Analysis of Fungal Species by Matrix-assisted Laser Desorption/Ionization Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Valentine, Nancy B.(BATTELLE (PACIFIC NW LAB)); Wahl, Jon H.(BATTELLE (PACIFIC NW LAB)); Kingsley, Mark T.(BATTELLE (PACIFIC NW LAB)); Wahl, Karen L.(BATTELLE (PACIFIC NW LAB))

    2001-12-01

    Intact spores and/or hyphae of Aspergillus niger, Rhizopus oryzae, Trichoderma reesei and Phanerochaete chrysosporium are analyzed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). This study investigates various methods of sample preparation and matrices to determine optimum collection and analysis criteria for fungal analysis by MALDI-MS. Fungi are applied to the MALDI sample target as untreated, sonicated, acid/heat treated, or blotted directly from the fungal culture with double-stick tape. Ferulic acid or sinapinic acid matrix solution is layered over the dried samples and analyzed by MALDI-MS. Statistical analysis of the data show that simply using double stick tape to collect and transfer to a MALDI sample plate typically worked as well as the other preparation methods, but requires the least sample handling.

  14. Ceftazidime Injection

    Science.gov (United States)

    ... is used to treat certain infections caused by bacteria including pneumonia and other lower respiratory tract (lung) infections; meningitis (infection of the membranes that surround the brain and spinal cord) and ... killing bacteria.Antibiotics such as ceftazidime injection will not work ...

  15. Teduglutide Injection

    Science.gov (United States)

    ... who need additional nutrition or fluids from intravenous (IV) therapy. Teduglutide injection is in a class of medications ... of the ingredients.tell your doctor and pharmacist what other prescription and nonprescription medications, vitamins, nutritional supplements, and herbal products you are taking ...

  16. Dexrazoxane Injection

    Science.gov (United States)

    ... are used to treat or prevent certain side effects that may be caused by chemotherapy medications. Dexrazoxane injection (Zinecard) is used to prevent or decrease heart damage caused by doxorubicin in women who are taking the medication to treat breast cancer that has spread to other parts of the ...

  17. Dulaglutide Injection

    Science.gov (United States)

    ... thyroid carcinoma (MTC; a type of thyroid cancer). Laboratory animals who were given dulaglutide developed tumors, but it ... your doctor will probably tell you not to use dulaglutide injection. If you ... doctor and the laboratory. Your doctor may order certain tests to check ...

  18. Albiglutide Injection

    Science.gov (United States)

    ... thyroid carcinoma (MTC; a type of thyroid cancer). Laboratory animals who were given medications similar to albiglutide developed ... your doctor will probably tell you not to use albiglutide injection. If you ... doctor and the laboratory. Your doctor may order certain tests to check ...

  19. Semaglutide Injection

    Science.gov (United States)

    ... thyroid carcinoma (MTC; a type of thyroid cancer). Laboratory animals who were given semaglutide developed tumors, but it ... your doctor will probably tell you not to use semaglutide injection. If you ... doctor and the laboratory. Your doctor may order certain tests to check ...

  20. Liraglutide Injection

    Science.gov (United States)

    ... thyroid carcinoma (MTC; a type of thyroid cancer). Laboratory animals who were given liraglutide developed tumors, but it ... your doctor will probably tell you not to use liraglutide injection. If you ... doctor and the laboratory. Your doctor may order certain tests to check ...

  1. Exenatide Injection

    Science.gov (United States)

    ... thyroid carcinoma (MTC; a type of thyroid cancer). Laboratory animals who were given exenatide developed tumors, but it ... your doctor will probably tell you not to use exenatide injection. If you ... doctor and the laboratory. Your doctor may order certain tests to check ...

  2. Etoposide Injection

    Science.gov (United States)

    ... used in combination with other medications to treat cancer of the testicles that has not improved or that has worsened after treatment with other medications or radiation therapy. Etoposide injection ... type of lung cancer (small cell lung cancer; SCLC). Etoposide is in ...

  3. Cefepime Injection

    Science.gov (United States)

    ... infection because they have a low number of white blood cells. Cefepime injection is in a class ... In case of overdose, call the poison control helpline at 1-800-222-1222. Information is also available online at https://www.poisonhelp.org/help. If the victim has ...

  4. Triptorelin Injection

    Science.gov (United States)

    ... puberty too soon, resulting in faster than normal bone growth and development of sexual characteristics) in children 2 years and older. Triptorelin injection is in a class of medications called gonadotropin-releasing hormone (GnRH) agonists. It works by decreasing the amount ...

  5. Imaging spectroscopy to assess the composition of ice surface materials and their impact on glacier mass balance

    Science.gov (United States)

    Naegeli, Kathrin; Huss, Matthias; Damm, Alexander; de Jong, Rogier; Schaepman, Michael; Hoelzle, Martin

    2014-05-01

    The ice-albedo feedback plays a crucial role in various glaciological processes, but especially influences ice melt. Glacier surface albedo is one of the most important variables in the energy balance of snow and ice, but depends in a complicated way on many factors, such as cryoconite concentration, impurities due to mineral dust, soot or organic matter, grain size or ice surface morphology. Our understanding on how these various factors influence glacier albedo is still limited hindering a spatially and temporally explicit parameterization of energy balance models and requiring strongly simplified assumptions on actual albedo values. Over the last two decades, several studies have focused on glacier surface albedo using automatic in-situ weather stations in combination with radiation measurement setups or satellite images. Due to limitations of both approaches in matching either the spatial or the temporal length scale of glacier albedo, still fairly little is known about the state, changes and impact of glacier surface albedo in the Swiss Alps, although there are obvious changes in surface characteristics on most alpine glaciers over the last years. With use of the APEX (Airborne Prism EXperiment) image spectrometer, measurements of reflected radiation were acquired in high spatial and spectral resolution on Glacier de la Plaine Morte, Switzerland, to explicitly analyse the ice surface. In-situ radiometric measurements were acquired with an ASD field spectrometer in parallel to APEX overflights. These data are intended to be used for validation purposes as well as input data for the linear spectral unmixing analysis of the APEX data. Seasonal glacier mass balance is monitored since five years using the direct glaciological method. This contribution presents a first evaluation of the data collected in summer 2013. The obtained in-situ and airborne reflectance measurements were used in combination with a spectral mixture analysis (SMA) approach to assess the

  6. Optimization of a microwave-assisted extraction large-volume injection and gas chromatography-ion trap mass spectrometry procedure for the determination of polybrominated diphenyl ethers, polybrominated biphenyls and polychlorinated naphthalenes in sediments

    Energy Technology Data Exchange (ETDEWEB)

    Yusa, V. [Analytical Chemistry Department, University of Valencia, Edifici Jeroni Munoz, 50th Dr. Moliner, 46100 Burjassot, Valencia (Spain); Pardo, O. [Analytical Chemistry Department, University of Valencia, Edifici Jeroni Munoz, 50th Dr. Moliner, 46100 Burjassot, Valencia (Spain); Pastor, A. [Analytical Chemistry Department, University of Valencia, Edifici Jeroni Munoz, 50th Dr. Moliner, 46100 Burjassot, Valencia (Spain)]. E-mail: Agustin.Pastor@uv.es; Guardia, M. de la [Analytical Chemistry Department, University of Valencia, Edifici Jeroni Munoz, 50th Dr. Moliner, 46100 Burjassot, Valencia (Spain)

    2006-01-31

    A sensitive and rapid method for the determination of polybrominated diphenyl ethers (PBDEs), polybrominated biphenyls (PBBs) and polychlorinated naphthalenes (PCNs) in sediment samples is proposed. The method involving microwave-assisted extraction (MAE) and large-volume injection (LVI) gas chromatography (GC)-ion trap mass spectrometry (ITMS), and the experimental conditions were optimized using the statistical design of experiments (DOE). A Plackett-Burman (P-B) design was chosen to estimate the influence of five factors, such as resonance excitation voltage (EV), isolation time (IT), excitation time (ET), ion source temperature (IST) and electron energy (EE) on the analytical response in the ITMS determination. In order to increase the analytical response, 70 {mu}L of the final extract were injected into the GC-tandem mass spectrometry (MS-MS) using a programmable temperature vaporizer (PTV). The factor settings involving injection temperature, vaporization temperature, vaporization time and flow during the evaporation step were previously optimized using a central composite design (CCD). The MAE was carried out using the hexane-acetone (1:1, v/v) mixture and the extraction conditions were optimized with a CCD. The highest response was obtained with a volume of 48 mL, a temperature of 152 deg. C and an extraction time of 24 min. The optimized method gives recoveries between 75 and 95% with relative standard deviations (R.S.D.) that ranged from 4 to 13%. The limit of detection (LOD) ranged between 4 and 20 pg g{sup -1} dry weight (dw) when 5 g of sediment were analyzed. The MAE method was applied to the analyses of polyhalogenated compounds in sediments collected in the harbour of Valencia (Spain). The proposed method may serve as an alternative for GC-negative chemical ionization (NCI)-MS and can be used in government testing programmes.

  7. A desk study of surface diffusion and mass transport in clay

    International Nuclear Information System (INIS)

    Cook, A.J.

    1989-01-01

    Research into the properties of clays as barrier materials for nuclear waste disposal has led to the realization that they have important transport properties which are relatively insignificant in most other geological materials. Sorption has always been regarded as a purely retarding mechanism, but laboratory experiments over the past decade have indicated that surface diffusion of sorbed cations is a potentially significant transport mechanism in both compacted montmorillonite, and biotite gneiss. The present desk study about these issues was part of the CEC coordinated project Mirage-Second phase, research area Natural analogues

  8. 21st century projections of surface mass balance changes for major drainage systems of the Greenland ice sheet

    International Nuclear Information System (INIS)

    Tedesco, M; Fettweis, X

    2012-01-01

    Outputs from the regional climate model Modèle Atmosphérique Régionale at a spatial resolution of 25 km are used to study 21st century projected surface mass balance (SMB) over six major drainage basins of the Greenland ice sheet (GrIS). The regional model is forced with the outputs of three different Earth System Models (CanESM2, NorESM1 and MIROC5) obtained when considering two greenhouse gas future scenarios with levels of CO 2 equivalent of, respectively, 850 and >1370 ppm by 2100. Results indicate that the increase in runoff due to warming will exceed the increased precipitation deriving from the increase in evaporation for all basins, with the amount of net loss of mass at the surface varying spatially. Basins along the southwest and north coast are projected to have the highest sensitivity of SMB to increasing temperatures. For these basins, the global temperature anomaly corresponding to a decrease of the SMB below the 1980–99 average (when the ice sheet was near the equilibrium) ranges between +0.60 and +2.16 °C. For the basins along the northwest and northeast, these values range between +1.50 and +3.40 °C. Our results are conservative as they do not account for ice dynamics and changes in the ice sheet topography. (letter)

  9. A comparative study of solid surface analyses between low energy ion scattering spectroscopy (ISS) and secondary ion mass spectroscopy (SIMS)

    International Nuclear Information System (INIS)

    Taya, Shunroku; Tsuyama, Hitoshi; Itoh, Michiyasu; Kanomata, Ichiro

    1977-01-01

    Experimental studies of solid surface analyses are carried out by means of low energy ion scattering spectroscopy (ISS) and secondary ion mass spectroscopy (SIMS). The instrument is composed of a HITACHI IMA-2 ion probe and a stigmatic second-order double focusing mass spectrometer (electric toroidal sector: r sub(e)=212 mm, PHI sub(e)=85 0 , c=0.5; uniform magnetic sector: r sub(m)=200 mm, PHI sub(m)=90 0 , epsilon 1 =32 0 , epsilon 2 =-10 0 ). ISS analyses are carried out using the electric toroidal sector, while SIMS analyses employ both the electric and magnetic sectors. Primary 5 keV argon and helium ion beams are used for ISS analyses, and 8 keV oxygen ion beams for SIMS analyses. An aluminium plate, an Au-Ag-Cu alloy and a GaP crystal are analyzed. The obtained ISS and SIMS spectra are compared. The element discrimination characteristics of ISS are much more accurate than those of SIMS. Maximum mass resolving powers are obtained at 30(50% valley separation) for ISS, and 11,000 (10% valley separation) for SIMS. (auth.)

  10. Broad tunable photonic microwave generation based on period-one dynamics of optical injection vertical-cavity surface-emitting lasers.

    Science.gov (United States)

    Ji, Songkun; Hong, Yanhua; Spencer, Paul S; Benedikt, Johannes; Davies, Iwan

    2017-08-21

    Photonic microwave generation based on period-one dynamics of an optically injected VCSEL has been study experimentally. The results have shown that the frequency of the generated microwave signal can be broadly tunable through the adjustment of the injection power and the frequency detuning. Strong optical injection power and higher frequency detuning are favorable for obtaining a high frequency microwave signal. These results are similar to those found in systems based on distributed feedback lasers and quantum dot lasers. The variation of the microwave power at the fundamental frequency and the second-harmonic distortion have also been characterized.

  11. Challenges in high accuracy surface replication for micro optics and micro fluidics manufacture

    DEFF Research Database (Denmark)

    Tosello, Guido; Hansen, Hans Nørgaard; Calaon, Matteo

    2014-01-01

    Patterning the surface of polymer components with microstructured geometries is employed in optical and microfluidic applications. Mass fabrication of polymer micro structured products is enabled by replication technologies such as injection moulding. Micro structured tools are also produced by r...

  12. A miniaturized laser-ablation mass spectrometer for in-situ measurements of isotope composition on solar body surfaces

    Science.gov (United States)

    Riedo, A.; Meyer, S.; Tulej, M.; Neuland, M.; Bieler, A.; Iakovleva, M.; Wurz, P.

    2012-04-01

    The in-situ analysis of extraterrestrial material onboard planetary rovers and landers is of considerable interest for future planetary space missions. Due to the low detection sensitivity of spectroscopic instruments, e.g. α-particle X-ray, γ-ray or neutron spectrometers, it is frequently possible to measure only major/minor elements in extraterrestrial materials. Nevertheless, the knowledge of minor/trace elements is of considerable interest to cosmochemistry. Chemistry puts constraints on the origin of solar system and its evolution enabling also a deeper inside to planetary transformation processes (e.g. volcanic surface alteration, space weathering). The isotopes play special role in analysis of the origin and transformation of planetary matter. They are robust tracers of the early events because their abundances are less disturbed as the elemental once. Nevertheless, if the isotope abundance ratios are fractionated, the underlying chemical and physical processes can be then encoded from the variations of abundance ratios. A detailed analysis of isotopic patterns of radiogenic elements can allow age dating of minerals and temporal evolution of planetary matter. High accuracy and sensitive measurements of isotopic pattern of bio-relevant elements, i.e., sulfur, found on planetary surfaces can be helpful for the identification of possible past and present extraterrestrial life in terms of biomarker identification. Our group has designed a self-optimizing miniaturized laser ablation time-of-flight mass spectrometer (LMS) for in situ planetary measurements (Wurz et al., 2012; Rohner et al., 2003). Initial studies utilizing IR laser radiation for ablation, atomization and ionization of solid materials indicated a high instrumental performance in terms of sensitivity and mass resolution (Tulej et al., 2011). Current studies are conducted with a UV radiation and a high spatial resolution is achieved by focussing the laser beam to 20µm spots onto the sample. The

  13. Shape estimation of the buried body from the ground surface potential distributions generated by current injection; Tsuryu ni yoru chihyomen den`i bunpu wo riyoshita maizobutsu keijo no suitei

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Y.; Okamoto, Y. [Chiba Institute of Technology, Chiba (Japan); Noguchi, K. [Waseda University, Tokyo (Japan); Teramachi, Y. [University of Industrial Technology, Kanagawa (Japan); Akabane, H.; Agu, M. [Ibaraki University, Ibaraki (Japan)

    1996-10-01

    Ground surface potential distribution generated by current injection was studied to estimate the shape of buried bodies. Since the uniform ground system including a homogeneous buried body is perfectly determined with the surface shape of a buried body and resistivities in/around a buried body, inversion is easy if the surface shape is described with some parameters. N electrodes are arranged in 2-D grid manner on the ground, and two electrodes among them are used for current injection, while the others for measurement of potentials. M times of measurements are repeated while changing combination of electrodes for current injection. The potential distribution measured by the mth electrode pair is represented by N-2 dimensional vectors. The square error between this distribution and calculated one is the function of k parameters on the surface shape and resistivities on a buried body. Both shape and resistivities can be estimated by solving an optimum value problem using the square error as evaluation function. Analysis is easy for a spherical body with 6 unknown parameters, however, it is difficult for more complex bodies than elliptical one or more than two bodies. 5 refs., 9 figs.

  14. The impact of a seasonally ice free Arctic Ocean on the temperature, precipitation and surface mass balance of Svalbard

    Directory of Open Access Journals (Sweden)

    J. J. Day

    2012-01-01

    Full Text Available The observed decline in summer sea ice extent since the 1970s is predicted to continue until the Arctic Ocean is seasonally ice free during the 21st Century. This will lead to a much perturbed Arctic climate with large changes in ocean surface energy flux. Svalbard, located on the present day sea ice edge, contains many low lying ice caps and glaciers and is expected to experience rapid warming over the 21st Century. The total sea level rise if all the land ice on Svalbard were to melt completely is 0.02 m.

    The purpose of this study is to quantify the impact of climate change on Svalbard's surface mass balance (SMB and to determine, in particular, what proportion of the projected changes in precipitation and SMB are a result of changes to the Arctic sea ice cover. To investigate this a regional climate model was forced with monthly mean climatologies of sea surface temperature (SST and sea ice concentration for the periods 1961–1990 and 2061–2090 under two emission scenarios. In a novel forcing experiment, 20th Century SSTs and 21st Century sea ice were used to force one simulation to investigate the role of sea ice forcing. This experiment results in a 3.5 m water equivalent increase in Svalbard's SMB compared to the present day. This is because over 50 % of the projected increase in winter precipitation over Svalbard under the A1B emissions scenario is due to an increase in lower atmosphere moisture content associated with evaporation from the ice free ocean. These results indicate that increases in precipitation due to sea ice decline may act to moderate mass loss from Svalbard's glaciers due to future Arctic warming.

  15. Quantification of four artificial sweeteners in Finnish surface waters with isotope-dilution mass spectrometry.

    Science.gov (United States)

    Perkola, Noora; Sainio, Pirjo

    2014-01-01

    The artificial sweeteners sucralose (SCL), acesulfame (ACS), saccharin (SAC), and cyclamate (CYC) have been detected in environmental waters in Europe and North America. Higher environmental levels are expected in view of the increasing consumption of these food additives. In this study, an isotope-dilution mass spectrometry (IDMS) LC-MS/MS method was developed and validated for quantifying the four artificial sweeteners in boreal lakes (n = 3) and rivers (n = 12). The highest concentrations of ACS, SAC, CYC and SCL were 9,600, 490, 210 and 1000 ng/L, respectively. ACS and SAC were detected in all studied samples, and CYC and SCL in 98% and 56% of the samples. Seasonal trends of ACS and SAC were observed in some rivers. ACS and SCL concentrations in rivers correlated linearly with population equivalents of the wastewater treatment plants in the catchment areas, whereas SAC and CYC concentrations depend more on the source. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Electrochemical separation and isotopic determination of thallium at the nanogram level by surface ionisation mass spectrometry

    International Nuclear Information System (INIS)

    Arden, J.W.

    1983-01-01

    A rapid low-blank procedure is described for the co-separation of thallium and lead by sequential cathodic and anodic electrodeposition from natural samples, especially complex natural silicates, for subsequent mass spectrometry. A micro anion-exchange procedure is also described for the separation of thallium and lead. Ion currents of 10 - 10 A can be obtained from 1 ng of thallium. The isotopic composition of 1 ng of thallium can be measured on a Faraday detector with a precision of 0.05-0.1%. The total procedural blank is 3 pg. By using stable isotope dilution, 0.2 ng of thallium can be measured with a precision of 0.6% with only a 2% blank correction. This allows the accurate determination of thallium in natural samples down to concentration levels of about 50 pg g - 1 . The detection limit is 50 fg. This procedure has been applied to meteorites and terrestrial rocks. The stable isotope dilution technique is suitable for geochemical, environmental and toxicological studies requiring a highly sensitive, accurate and precise method for the determination of thallium. (Auth.)

  17. Entrainment of bed material by Earth-surface mass flows: review and reformulation of depth-integrated theory

    Science.gov (United States)

    Iverson, Richard M.; Chaojun Ouyang,

    2015-01-01

    Earth-surface mass flows such as debris flows, rock avalanches, and dam-break floods can grow greatly in size and destructive potential by entraining bed material they encounter. Increasing use of depth-integrated mass- and momentum-conservation equations to model these erosive flows motivates a review of the underlying theory. Our review indicates that many existing models apply depth-integrated conservation principles incorrectly, leading to spurious inferences about the role of mass and momentum exchanges at flow-bed boundaries. Model discrepancies can be rectified by analyzing conservation of mass and momentum in a two-layer system consisting of a moving upper layer and static lower layer. Our analysis shows that erosion or deposition rates at the interface between layers must in general satisfy three jump conditions. These conditions impose constraints on valid erosion formulas, and they help determine the correct forms of depth-integrated conservation equations. Two of the three jump conditions are closely analogous to Rankine-Hugoniot conditions that describe the behavior of shocks in compressible gasses, and the third jump condition describes shear traction discontinuities that necessarily exist across eroding boundaries. Grain-fluid mixtures commonly behave as compressible materials as they undergo entrainment, because changes in bulk density occur as the mixtures mobilize and merge with an overriding flow. If no bulk density change occurs, then only the shear-traction jump condition applies. Even for this special case, however, accurate formulation of depth-integrated momentum equations requires a clear distinction between boundary shear tractions that exist in the presence or absence of bed erosion.

  18. Subcutaneous or intramuscular injections of insulin in children. Are we injecting where we think we are?

    Science.gov (United States)

    Polak, M; Beregszaszi, M; Belarbi, N; Benali, K; Hassan, M; Czernichow, P; Tubiana-Rufi, N

    1996-12-01

    This study was designed to assess the insulin injection location in a group of children who had their injection according to their daily practice, thought to lead to subcutaneous injections. The location of the insulin deposit at the injection site was visualized using an ultrasound device. The exact insulin injection location could be localized, and 18 of 59 injections (30.5%) (one injection for each child) were in the intramuscular tissue. Of the children who had intramuscular injection, 15 of 18 were boys. The children who had an intramuscular injection had a significantly lower percentile of BMI (mean +/- SE: 47 +/- 8 vs. 72 +/- 4, P = 0.004), lower distance from skin surface to muscle fascia without a skinfold (5.6 +/- 0.6 vs. 11 +/- 0.7 mm, P insulin injection. We identified a group of children at risk for intramuscular insulin injections and that may deserve specific injection technique and advice.

  19. Modelling the climate and surface mass balance of polar ice sheets using RACMO2 - Part 1: Greenland (1958-2016)

    Science.gov (United States)

    Noël, Brice; van de Berg, Willem Jan; Melchior van Wessem, J.; van Meijgaard, Erik; van As, Dirk; Lenaerts, Jan T. M.; Lhermitte, Stef; Kuipers Munneke, Peter; Smeets, C. J. P. Paul; van Ulft, Lambertus H.; van de Wal, Roderik S. W.; van den Broeke, Michiel R.

    2018-03-01

    We evaluate modelled Greenland ice sheet (GrIS) near-surface climate, surface energy balance (SEB) and surface mass balance (SMB) from the updated regional climate model RACMO2 (1958-2016). The new model version, referred to as RACMO2.3p2, incorporates updated glacier outlines, topography and ice albedo fields. Parameters in the cloud scheme governing the conversion of cloud condensate into precipitation have been tuned to correct inland snowfall underestimation: snow properties are modified to reduce drifting snow and melt production in the ice sheet percolation zone. The ice albedo prescribed in the updated model is lower at the ice sheet margins, increasing ice melt locally. RACMO2.3p2 shows good agreement compared to in situ meteorological data and point SEB/SMB measurements, and better resolves the spatial patterns and temporal variability of SMB compared with the previous model version, notably in the north-east, south-east and along the K-transect in south-western Greenland. This new model version provides updated, high-resolution gridded fields of the GrIS present-day climate and SMB, and will be used for projections of the GrIS climate and SMB in response to a future climate scenario in a forthcoming study.

  20. Determination of platinum surface contamination in veterinary and human oncology centres using inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Janssens, T; Brouwers, E E M; de Vos, J P; de Vries, N; Schellens, J H M; Beijnen, J H

    2015-09-01

    The objective of this study was to determine the surface contamination with platinum-containing antineoplastic drugs in veterinary and human oncology centres. Inductively coupled plasma mass spectrometry was used to measure platinum levels in surface samples. In veterinary and human oncology centres, 46.3 and 68.9% of the sampled surfaces demonstrated platinum contamination, respectively. Highest platinum levels were found in the preparation rooms (44.6 pg cm(-2)) in veterinary centres, while maximal levels in human centres were found in oncology patient-only toilets (725 pg cm(-2)). Transference of platinum by workers outside areas where antineoplastic drugs were handled was observed in veterinary and human oncology centres. In conclusion, only low levels of platinum contamination attributable to carboplatin were found in the sampled veterinary oncology centres. However, dispersion of platinum outside areas where antineoplastic drugs were handled was detected in veterinary and human oncology centres. Consequently, not only personnel, but also others may be exposed to platinum. © 2013 Blackwell Publishing Ltd.