WorldWideScience

Sample records for surface magnetometer employs

  1. The MASCOT Magnetometer

    Science.gov (United States)

    Herčík, David; Auster, Hans-Ulrich; Blum, Jürgen; Fornaçon, Karl-Heinz; Fujimoto, Masaki; Gebauer, Kathrin; Güttler, Carsten; Hillenmaier, Olaf; Hördt, Andreas; Liebert, Evelyn; Matsuoka, Ayako; Nomura, Reiko; Richter, Ingo; Stoll, Bernd; Weiss, Benjamin P.; Glassmeier, Karl-Heinz

    2017-07-01

    The Mobile Asteroid Scout (MASCOT) is a small lander on board the Hayabusa2 mission of the Japan Aerospace Exploration Agency to the asteroid 162173 Ryugu. Among the instruments on MASCOT is a fluxgate magnetometer, the MASCOT Magnetometer (MasMag). The magnetometer is a lightweight (˜280 g) and low power (˜0.5 W) triaxial fluxgate magnetometer. Magnetic field measurements during the landing period and during the surface operational phase shall provide information about any intrinsic magnetic field of the asteroid and its remanent magnetization. This could provide important constraints on planet formation and the thermal and aqueous evolution of primitive asteroids.

  2. Comparison of a triaxial fluxgate magnetometer and Toftness sensometer for body surface EMF measurement.

    Science.gov (United States)

    Zhang, John; Toftness, Dave; Snyder, Brian; Nosco, Dennis; Balcavage, Walter; Nindl, Gabi

    2004-12-01

    The use of magnetic fields to treat disease has intrigued mankind since the time of the ancient Greeks. More recently it has been shown that electromagnetic field (EMF) treatment aids bone healing, and repetitive transcranial magnetic stimulation (rTMS) appears to be beneficial in treating schizophrenia and depression. Since external EMFs influence internal body processes, we hypothesized that measurement of body surface EMFs might be used to detect disease states and direct the course of subsequent therapy. However, measurement of minute body surface EMFs requires use of a sensitive and well documented magnetometer. In this study we evaluated the sensitivity and frequency response of a fluxgate magnetometer with a triaxial probe for use in detecting body surface EMF and we compared the magnetometer readings with a signal from a Toftness Sensometer, operated by an experienced clinician, in the laboratory and in a clinical setting. A Peavy Audio Amplifier and variable power output Telulex signal generator were used to develop 50 microT EMFs in a three coil Merritt coil system. A calibrated magnetometer was used to set a 60 Hz 50 microT field in the coil and an ammeter was used to measure the current required to develop the 50 microT field. At frequencies other than 60 Hz, the field strength was maintained at 50 microT by adjusting the Telulex signal output to keep the current constant. The field generated was monitored using a 10 turn coil connected to an oscilloscope. The oscilloscope reading indicated that the field strength was the same at all frequencies tested. To determine if there was a correspondence between the signals detected by a fluxgate magnetometer (FGM1) and the Toftness Sensometer both devices were placed in the Merritt coil and readings were recorded from the FGM1 and compared with the ability of a highly experienced Toftness operator to detect the 50 microT field. Subsequently, in a clinical setting, FGM1 readings made by an FGM1 technician and

  3. Man-Portable Simultaneous Magnetometer and EM System (MSEMS)

    Science.gov (United States)

    2008-12-01

    limited to cesium vapor magnetometers outputting a Larmor signal. It cannot, as presently configured, be used with less expensive fluxgate magnetometers ...pulses to convert the frequency-based Larmor signal into nT. A fluxgate magnetometer does not employ the resonance mechanism of an alkali vapor...Simultaneous Magnetometer and EM System (MSEMS) December 2008 Report Documentation Page Form ApprovedOMB No. 0704-0188 Public reporting burden for the

  4. Magnetometer calibration and test procedure

    International Nuclear Information System (INIS)

    Squier, D.M.

    1997-01-01

    Nuclear waste has been sluiced and pumped from storage tank 241-AX-104, leaving a contaminated heel volume. These operations did not include measurements of the removed waste volume leaving an unknown heel volume in the tank. A magnetometer transducer will be lowered through tank riser ports to rest on the heel's surface. The heel thickness will control the distance between the transducer and the tank's bottom The instrument's output varies with the distance from a magnetic mass, such as the tank's steel bottom, thereby enabling a measurement of the heel depth. Measurements at several tank locations will permit an estimate of the tank's heel volume. The magnetometer's output is influenced by adjacent magnetic materials, such as the tank walls, air lift circulators or other equipment installed in the tank. An adjacent vertical steel surface produces a voltage offset in the instrument's output. Measurements near a tank wall or other tank components may be corrected by noting the offset before the instrument's output is influenced by the tank bottom. An unlevel or uneven heel surface could orient the magnetometer transducer so that it is not vertically level. The magnetometer readings are influenced by these skewed transducer orientations. The magnitude of these errors and offsets must be characterized to bound the heel volume estimate range. The data collected by this activity will be statistically analyzed by SESC to state the confidence level of the heel volume estimates. A test report will document the results of the measurements

  5. Choice of Magnetometers and Gradiometers after Signal Space Separation.

    Science.gov (United States)

    Garcés, Pilar; López-Sanz, David; Maestú, Fernando; Pereda, Ernesto

    2017-12-16

    Modern Elekta Neuromag MEG devices include 102 sensor triplets containing one magnetometer and two planar gradiometers. The first processing step is often a signal space separation (SSS), which provides a powerful noise reduction. A question commonly raised by researchers and reviewers relates to which data should be employed in analyses: (1) magnetometers only, (2) gradiometers only, (3) magnetometers and gradiometers together. The MEG community is currently divided with regard to the proper answer. First, we provide theoretical evidence that both gradiometers and magnetometers result from the backprojection of the same SSS components. Then, we compare resting state and task-related sensor and source estimations from magnetometers and gradiometers in real MEG recordings before and after SSS. SSS introduced a strong increase in the similarity between source time series derived from magnetometers and gradiometers (r² = 0.3-0.8 before SSS and r² > 0.80 after SSS). After SSS, resting state power spectrum and functional connectivity, as well as visual evoked responses, derived from both magnetometers and gradiometers were highly similar (Intraclass Correlation Coefficient > 0.8, r² > 0.8). After SSS, magnetometer and gradiometer data are estimated from a single set of SSS components (usually ≤ 80). Equivalent results can be obtained with both sensor types in typical MEG experiments.

  6. Silent Localization of Underwater Sensors Using Magnetometers

    Directory of Open Access Journals (Sweden)

    Jonas Callmer

    2010-01-01

    Full Text Available Sensor localization is a central problem for sensor networks. If the sensor positions are uncertain, the target tracking ability of the sensor network is reduced. Sensor localization in underwater environments is traditionally addressed using acoustic range measurements involving known anchor or surface nodes. We explore the usage of triaxial magnetometers and a friendly vessel with known magnetic dipole to silently localize the sensors. The ferromagnetic field created by the dipole is measured by the magnetometers and is used to localize the sensors. The trajectory of the vessel and the sensor positions are estimated simultaneously using an Extended Kalman Filter (EKF. Simulations show that the sensors can be accurately positioned using magnetometers.

  7. Fluxgate vector magnetometers: Compensated multi-sensor devices for ground, UAV and airborne magnetic survey for various application in near surface geophysics

    Science.gov (United States)

    Gavazzi, Bruno; Le Maire, Pauline; Munschy, Marc; Dechamp, Aline

    2017-04-01

    Fluxgate 3-components magnetometer is the kind of magnetometer which offers the lightest weight and lowest power consumption for the measurement of the intensity of the magnetic field. Moreover, vector measurements make it the only kind of magnetometer allowing compensation of magnetic perturbations due to the equipment carried with it. Unfortunately, Fluxgate magnetometers are quite uncommon in near surface geophysics due to the difficulty to calibrate them precisely. The recent advances in calibration of the sensors and magnetic compensation of the devices from a simple process on the field led Institut de Physique du Globe de Strasbourg to develop instruments for georeferenced magnetic measurements at different scales - from submetric measurements on the ground to aircraft-conducted acquisition through the wide range offered by unmanned aerial vehicles (UAVs) - with a precision in the order of 1 nT. Such equipment is used for different kind of application: structural geology, pipes and UXO detection, archaeology.

  8. Long-term vacuum tests of single-mode vertical cavity surface emitting laser diodes used for a scalar magnetometer

    Science.gov (United States)

    Hagen, C.; Ellmeier, M.; Piris, J.; Lammegger, R.; Jernej, I.; Magnes, W.; Murphy, E.; Pollinger, A.; Erd, C.; Baumjohann, W.

    2017-11-01

    Scalar magnetometers measure the magnitude of the magnetic field, while vector magnetometers (mostly fluxgate magnetometers) produce three-component outputs proportional to the magnitude and the direction of the magnetic field. While scalar magnetometers have a high accuracy, vector magnetometers suffer from parameter drifts and need to be calibrated during flight. In some cases, full science return can only be achieved by a combination of vector and scalar magnetometers.

  9. Obtaining 'images' from iron objects using a 3-axis fluxgate magnetometer

    International Nuclear Information System (INIS)

    Chilo, Jose; Jabor, Abbas; Lizska, Ludwik; Eide, Age J.; Lindblad, Thomas

    2007-01-01

    Magnetic objects can cause local variations in the Earth's magnetic field that can be measured with a magnetometer. Here we used tri-axial magnetometer measurements and an analysis method employing wavelet techniques to determine the 'signature' or 'fingerprint' of different iron objects. Clear distinctions among the iron samples were observed. The time-dependent changes in the frequency powers were extracted by use of the Morlet wavelet corresponding to frequency bands from 0.1 to 100 Hz

  10. Calibration of three-axis magnetometers with differential evolution algorithm

    International Nuclear Information System (INIS)

    Pang, Hongfeng; Zhang, Qi; Wang, Wei; Wang, Junya; Li, Ji; Luo, Shitu; Wan, Chengbiao; Chen, Dixiang; Pan, Mengchun; Luo, Feilu

    2013-01-01

    The accuracy of three-axis magnetometers is influenced by different scale and bias of each axis and nonorthogonality between axes. One limitation of traditional iteration methods is that initial parameters influence the calibration, thus leading to the local optimal or wrong results. In this paper, a new method is proposed to calibrate three-axis magnetometers. To employ this method, a nonmagnetic rotation platform, a proton magnetometer, a DM-050 three-axis magnetometer and the differential evolution (DE) algorithm are used. The performance of this calibration method is analyzed with simulation and experiment. In simulation, the calibration results of DE, unscented Kalman filter (UKF), recursive least squares (RLS) and genetic algorithm (GA) are compared. RMS error using DE is least, which is reduced from 81.233 nT to 1.567 nT. Experimental results show that comparing with UKF, RLS and GA, the DE algorithm has not only the least calibration error but also the best robustness. After calibration, RMS error is reduced from 68.914 nT to 2.919 nT. In addition, the DE algorithm is not sensitive to initial parameters, which is an important advantage compared with traditional iteration algorithms. The proposed algorithm can avoid the troublesome procedure to select suitable initial parameters, thus it can improve the calibration performance of three-axis magnetometers. - Highlights: • The calibration results and robustness of UKF, GA, RLS and DE algorithm are analyzed. • Calibration error of DE is the least in simulation and experiment. • Comparing with traditional calibration algorithms, DE is not sensitive to initial parameters. • It can improve the calibration performance of three-axis magnetometers

  11. Field Measurement of Surface Ship Magnetic Signature Using Multiple AUVs

    Science.gov (United States)

    2009-10-01

    been equipped with a tri-axial fluxgate magnetometer and used to perform preliminary magnetic field measurements. Measurements of this type will be...mounted on the AUVs, shown in Fig. 1, was a three-axis fluxgate type [16] magnetometer with a range of ±100,000 nT and a sensitivity of 100μV/nT. The...surface ship. The system will employ a formation of multiple AUVs, each equipped with a magnetometer . The objective is to measure total magnetic

  12. Rad-Hard Sigma-Delta 3-channel ADC for Fluxgate Magnetometers, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed project aims to develop a multi-channel analog to digital converter (ADC) required for a fluxgate magnetometer (EPD) employed on NASA's planetary...

  13. Radiation tolerance of a spin-dependent tunnelling magnetometer for space applications

    International Nuclear Information System (INIS)

    Persson, Anders; Thornell, Greger; Nguyen, Hugo

    2011-01-01

    To meet the increasing demand for miniaturized space instruments, efforts have been made to miniaturize traditional magnetometers, e.g. fluxgate and spin-exchange relaxation-free magnetometers. These have, for different reasons, turned out to be difficult. New technologies are needed, and promising in this respect are tunnelling magnetoresistive (TMR) magnetometers, which are based on thin film technology. However, all new space devices first have to be qualified, particularly in terms of radiation resistance. A study on TMR magnetometers' vulnerability to radiation is crucial, considering the fact that they employ a dielectric barrier, which can be susceptible to charge trapping from ionizing radiation. Here, a TMR-based magnetometer, called the spin-dependent tunnelling magnetometer (SDTM), is presented. A magnetometer chip consisting of three Wheatstone bridges, with an angular pitch of 120°, was fabricated using microstructure technology. Each branch of the Wheatstone bridges consists of eight pairs of magnetic tunnel junctions (MTJs) connected in series. Two such chips are used to measure the three-dimensional magnetic field vector. To investigate the SDTM's resistance to radiation, one branch of a Wheatstone bridge was irradiated with gamma rays from a Co 60 source with a dose rate of 10.9 rad min −1 to a total dose of 100 krad. The TMR of the branch was monitored in situ, and the easy axis TMR loop and low-frequency noise characteristics of a single MTJ were acquired before and after irradiation with the total dose. It was concluded that radiation did not influence the MTJs in any noticeable way in terms of the TMR ratio, coercivity, magnetostatic coupling or low-frequency noise

  14. Obtaining 'images' from iron objects using a 3-axis fluxgate magnetometer

    Energy Technology Data Exchange (ETDEWEB)

    Chilo, Jose [University of Gaevle, S-80176 Gaevle (Sweden); Jabor, Abbas [Royal Institute of Technology, Department of Physics, S-106 91 Stockholm (Sweden); Lizska, Ludwik [Swedish Institute of Space Physics in Umea (Sweden); Eide, Age J. [Ostfold University College, N-1757 Halden (Norway); Lindblad, Thomas [Royal Institute of Technology, Department of Physics, S-106 91 Stockholm (Sweden)], E-mail: lindblad@particle.kth.se

    2007-10-01

    Magnetic objects can cause local variations in the Earth's magnetic field that can be measured with a magnetometer. Here we used tri-axial magnetometer measurements and an analysis method employing wavelet techniques to determine the 'signature' or 'fingerprint' of different iron objects. Clear distinctions among the iron samples were observed. The time-dependent changes in the frequency powers were extracted by use of the Morlet wavelet corresponding to frequency bands from 0.1 to 100 Hz.

  15. Harmonic detection of magnetic resonance for sensitivity improvement of optical atomic magnetometers

    Energy Technology Data Exchange (ETDEWEB)

    Ranjbaran, M. [Laser and Plasma Research Institute, Shahid Beheshti University, Tehran (Iran, Islamic Republic of); Tehranchi, M.M., E-mail: teranchi@sbu.ac.ir [Laser and Plasma Research Institute, Shahid Beheshti University, Tehran (Iran, Islamic Republic of); Physics Department, Shahid Beheshti University, Tehran (Iran, Islamic Republic of); Hamidi, S.M. [Laser and Plasma Research Institute, Shahid Beheshti University, Tehran (Iran, Islamic Republic of); Khalkhali, S.M.H. [Physics Department, Kharazmi University, Tehran (Iran, Islamic Republic of)

    2017-02-15

    Highly sensitive atomic magnetometers use optically detected magnetic resonance of atomic spins to measure extremely weak magnetic field changes. The magnetometer sensitivity is directly proportional to the ratio of intensity to line-shape of the resonance signal. To obtain narrower resonance signal, we implemented harmonic detection of magnetic resonance method in M{sub x} configuration. The nonlinear spin polarization dynamics in detection of the higher harmonics were employed in phenomenological Bloch equations. The measured and simulated harmonic components of the resonance signals in frequency domain yielded significantly narrower line-width accompanying much improved sensitivity. Our results confirm the sensitivity improvement by a factor of two in optical atomic magnetometer via second harmonic signal which can open a new insight in the weak magnetic field measurement system design. - Highlights: • Highly sensitive atomic magnetometers have been used to measure weak magentic filed. • To obtain narrower resonance signal, we impalnted harmonic detection of magnetic resonance. • The nonlinear spin polarization dynamics in detetion of the higher harmonics were imployed.

  16. GOES Space Environment Monitor, Magnetometer

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Three orthogonal flux-gate magnetometer elements, (spinning twin fluxgate magnetometer prior to GOES-8) provide magnetic field measurements in three mutually...

  17. Digitalization of highly precise fluxgate magnetometers

    DEFF Research Database (Denmark)

    Cerman, Ales; Kuna, A.; Ripka, P.

    2005-01-01

    This paper describes the theory behind all three known ways of digitalizing the fluxgate magnetometers: analogue magnetometers with digitalized output using high resolution ADC, application of the delta-sigma modulation to the sensor feedback loop and fully digital signal detection. At present time...... the Delta-Sigma ADCs are mostly used for the digitalization of the highly precise fluxgate magnetorneters. The relevant part of the paper demonstrates some pitfalls of their application studied during the design of the magnetometer for the new Czech scientific satellite MIMOSA. The part discussing...... the application of the A-E modulation to the sensor feedback loop theoretically derives the main advantage of this method-increasing of the modulation order and shows its real potential compared to the analog magnetometer with consequential digitalization. The comparison is realized on the modular magnetometer...

  18. Tuned cavity magnetometer sensitivity.

    Energy Technology Data Exchange (ETDEWEB)

    Okandan, Murat; Schwindt, Peter

    2009-09-01

    We have developed a high sensitivity (magnetometer that utilizes a novel optical (interferometric) detection technique. Further miniaturization and low-power operation are key advantages of this magnetometer, when compared to systems using SQUIDs which require liquid Helium temperatures and associated overhead to achieve similar sensitivity levels.

  19. Low Cost, Low Power, High Sensitivity Magnetometer

    Science.gov (United States)

    2008-12-01

    which are used to measure the small magnetic signals from brain. Other types of vector magnetometers are fluxgate , coil based, and magnetoresistance...concentrator with the magnetometer currently used in Army multimodal sensor systems, the Brown fluxgate . One sees the MEMS fluxgate magnetometer is...Guedes, A.; et al., 2008: Hybrid - LOW COST, LOW POWER, HIGH SENSITIVITY MAGNETOMETER A.S. Edelstein*, James E. Burnette, Greg A. Fischer, M.G

  20. Scalar magnetometers for space applications

    DEFF Research Database (Denmark)

    Primdahl, Fritz

    A survey of existing instrumentation and developments is presented emphasizing instrumentation for in-flight calibration of vector magnetometers on magnetic mapping missions. Proton free or forced precession magnetometers are at the focus as calibration references, because the proton gyromagnetic...

  1. The Magnetospheric Multiscale Magnetometers

    Science.gov (United States)

    Russell, C. T.; Anderson, B. J.; Baumjohann, W.; Bromund, K. R.; Dearborn, D.; Fischer, D.; Le, G.; Leinweber, H. K.; Leneman, D.; Magnes, W.; hide

    2014-01-01

    The success of the Magnetospheric Multiscale mission depends on the accurate measurement of the magnetic field on all four spacecraft. To ensure this success, two independently designed and built fluxgate magnetometers were developed, avoiding single-point failures. The magnetometers were dubbed the digital fluxgate (DFG), which uses an ASIC implementation and was supplied by the Space Research Institute of the Austrian Academy of Sciences and the analogue magnetometer (AFG) with a more traditional circuit board design supplied by the University of California, Los Angeles. A stringent magnetic cleanliness program was executed under the supervision of the Johns Hopkins University,s Applied Physics Laboratory. To achieve mission objectives, the calibration determined on the ground will be refined in space to ensure all eight magnetometers are precisely inter-calibrated. Near real-time data plays a key role in the transmission of high-resolution observations stored onboard so rapid processing of the low-resolution data is required. This article describes these instruments, the magnetic cleanliness program, and the instrument pre-launch calibrations, the planned in-flight calibration program, and the information flow that provides the data on the rapid time scale needed for mission success.

  2. Coherent population trapping magnetometer by differential detecting magneto–optic rotation effect

    International Nuclear Information System (INIS)

    Zhang Fan; Tian Yuan; Zhang Yi; Gu Si-Hong

    2016-01-01

    A pocket coherent population trapping (CPT) atomic magnetometer scheme that uses a vertical cavity surface emitting laser as a light source is proposed and experimentally investigated. Using the differential detecting magneto–optic rotation effect, a CPT spectrum with the background canceled and a high signal-to-noise ratio is obtained. The experimental results reveal that the sensitivity of the proposed scheme can be improved by half an order, and the ability to detect weak magnetic fields is extended one-fold. Therefore, the proposed scheme is suited to realize a pocket-size CPT magnetometer. (paper)

  3. Scalar Calibration of Vector Magnetometers

    DEFF Research Database (Denmark)

    Merayo, José M.G.; Brauer, Peter; Primdahl, Fritz

    2000-01-01

    The calibration parameters of a vector magnetometer are estimated only by the use of a scalar reference magnetometer. The method presented in this paper differs from those previously reported in its linearized parametrization. This allows the determination of three offsets or signals in the absence...

  4. Performances and place of magnetometers based on amorphous wires compared to conventional magnetometers

    International Nuclear Information System (INIS)

    Robbes, D.; Dolabdjian, C.; Monfort, Y.

    2002-01-01

    We discuss and compare performances of various room temperature magnetometers. The work is directed towards the search of those magnetometers having a high sensitivity (>1000 V/T), a very low noise level (>1 pT/√Hz at white noise) attainable in a volume typically smaller than 1 cm 3 . The choice of this set of parameters is related to the useful comparison of room temperature magnetometers versus cryogenic ones, such as Superconducting Quantum Interferometer Devices (SQUIDs). The latter have highly degraded performances when their working operations needs an open unshielded environment as required for example in industrial application (non-destructive evaluation). SQUIDs have also a rather poor spatial resolution, and could be replaced by room temperature sensors in some magnetic imaging systems, which require a high spatial resolution. The paper is 'highlighted' in the field of magnetic sensors based on amorphous magnetic wires that were used to carry out wide bandwidth (>100 kHz), very low noise flux gate (∼pT/√Hz at white noise) and highly sensitive, low noise magnetometers (∼pT/√Hz at white noise) Colpitts oscillator configuration use by K. Bushida's

  5. Magnetogama: an open schematic magnetometer

    Science.gov (United States)

    Wahyudi; Khakhim, Nurul; Kuntoro, Tri; Mardiatno, Djati; Rakhman, Afif; Setyo Handaru, Anas; Akhmad Mufaqih, Adien; Marwan Irnaka, Theodosius

    2017-09-01

    Magnetogama is an open schematic hand-assembled fluxgate magnetometer. Compared to another magnetometer, Magnetogama has more benefit concerning its price and its ease of use. Practically Magnetogama can be utilized either in land or attached to an unmanned aerial vehicle (UAV). Magnetogama was designed to give open access to a cheap and accurate alternative to magnetometer sensor. Therefore it can be used as a standard design which is directly applicable to the low-budget company or education purposes. Schematic, code and several verification tests were presented in this article ensuring its reproducibility. Magnetogama has been tested with two kind of tests: a comparison with two nearest observatories at Learmonth (LRM) and Kakadu (KDU) and the response of magnetic substance.

  6. The Pioneer XI high field fluxgate magnetometer

    Science.gov (United States)

    Acuna, M. A.; Ness, N. F.

    1975-01-01

    The high field fluxgate magnetometer experiment flown aboard the Pioneer XI spacecraft is described. This extremely simple instrument was used to extend the spacecraft's upper-limit measurement capability by approximately an order of magnitude (from 0.14 mT to 1.00 mT) with minimum power and volume requirements. This magnetometer was designed to complement the low-field measurements provided by a helium vector magnetometer and utilizes magnetic ring core sensors with biaxial orthogonal sense coils. The instrument is a single-range, triaxial-fluxgate magnetometer capable of measuring fields of up to 1 mT along each orthogonal axis, with a maximum resolution of 1 microT.

  7. Development of a nuclear precession magnetometer

    International Nuclear Information System (INIS)

    Virgens Alves, J.G. das.

    1983-12-01

    The objective of this thesis was to develop a proton precession magnetometer for geophysical prospecting and base stations. The proton procession magnetometer measures the total magnetic fields intensity. It operates on the basis of nuclear magnetic resonance by determining the processing frequency of protons of a non viscous liquid in the terrestrial magnetic fields. The instrument was tested in field to evaluate signal/noise ratio, supportable gradient and battery consumption. Application test was carried out to take diurnal variation data and, reconnaissance and detail surveys data on an archaeological site in the Marajo Island-Pa. The test results were confronted with two commercial magnetometers-GP-70, McPhar e G-816, Geometric - and, with data from Observatorio Magnetico Ilha de Tatuoca as well. For all cases, the data comparison showed a good performance of the magnetometer tested. (author)

  8. High transition-temperature SQUID magnetometers and practical applications

    International Nuclear Information System (INIS)

    Dantsker, E.; Lawrence Berkeley National Lab., CA

    1997-05-01

    The design, fabrication and performance of SQUID magnetometers based on thin films of the high-transition temperature superconductor YBa 2 Cu 3 O 7-x (YBCO) are described. Essential to the achieving high magnetic field resolution at low frequencies is the elimination of 1/f flux noise due to thermally activated hopping of flux vortices between pinning sites in the superconducting films. Through improvements in processing, 1/f noise in single layer YBCO thin films and YBCO-SrTiO 3 -YBCO trilayers was systematically reduced to allow fabrication of sensitive SQUID magnetometers. Both single-layer directly coupled SQUID magnetometers and multilayer magnetometers were fabricated, based on the dc SQUID with bicrystal grain boundary Josephson junctions. Multilayer magnetometers had a lower magnetic field noise for a given physical size due to greater effective sensing areas. A magnetometer consisting of a SQUID inductively coupled to the multiturn input coil of a flux transformer in a flip-chip arrangement had a field noise of 27 fT Hz -1/2 at 1 Hz and 8.5 fT Hz -1/2 at 1 kHz. A multiloop multilayer SQUID magnetometer had a field noise of 37 fT Hz -1/2 at 1 Hz and 18 fT Hz -1/2 at 1 kHz. A three-axis SQUID magnetometer for geophysical applications was constructed and operated in the field in the presence of 60 Hz and radiofrequency noise. Clinical quality magnetocardiograms were measured using multilayer SQUID magnetometers in a magnetically shielded room

  9. Magnetometer and Gyroscope Calibration Method with Level Rotation

    Directory of Open Access Journals (Sweden)

    Zongkai Wu

    2018-03-01

    Full Text Available Micro electro mechanical system (MEMS gyroscopes and magnetometers are usually integrated into a sensor module or chip and widely used in a variety of applications. In existing integrated gyroscope and magnetometer calibration methods, rotation in all possible orientations is a necessary condition for a good calibration result. However, rotation around two or more axes is difficult to attain, as it is limited by the range of movement of vehicles such as cars, ships, or planes. To solve this problem, this paper proposes an integrated magnetometer and gyroscope calibration method with level rotation. The proposed method presents a redefined magnetometer output model using level attitude. New gyroscope and magnetometer calibration models are then deduced. In addition, a simplified cubature Kalman filter (CKF is established to estimate calibration parameters. This method possesses important value for application in actual systems, as it only needs level rotation for real-time calibration of gyroscopes and magnetometers. Theoretical analysis and test results verify the validity and feasibility of this method.

  10. Magnetogama: an open schematic magnetometer

    Directory of Open Access Journals (Sweden)

    Wahyudi

    2017-09-01

    Full Text Available Magnetogama is an open schematic hand-assembled fluxgate magnetometer. Compared to another magnetometer, Magnetogama has more benefit concerning its price and its ease of use. Practically Magnetogama can be utilized either in land or attached to an unmanned aerial vehicle (UAV. Magnetogama was designed to give open access to a cheap and accurate alternative to magnetometer sensor. Therefore it can be used as a standard design which is directly applicable to the low-budget company or education purposes. Schematic, code and several verification tests were presented in this article ensuring its reproducibility. Magnetogama has been tested with two kind of tests: a comparison with two nearest observatories at Learmonth (LRM and Kakadu (KDU and the response of magnetic substance.

  11. Vector Fluxgate Magnetometer (VMAG) Development for DSX

    Science.gov (United States)

    2010-06-03

    AFRL-RV-HA-TR-2010-1056 Vector Fluxgate Magnetometer (VMAG) Development for DSX Mark B. Moldwin UCLA Institute of Geophysics... Fluxgate Magnetometer (VMAG) Development for DSX 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 62601F 6. AUTHOR(S) Mark B. Moldwin 5d. PROJECT...axis fluxgate magnetometer for the AFRL-mission. The instrument is designed to measure the medium-Earth orbit geomagnetic field with precision of 0.1

  12. High transition-temperature SQUID magnetometers and practical applications

    Energy Technology Data Exchange (ETDEWEB)

    Dantsker, Eugene [Univ. of California, Berkeley, CA (United States). Dept. of Physics

    1997-05-01

    The design, fabrication and performance of SQUID magnetometers based on thin films of the high-transition temperature superconductor YBa2Cu3O7-x (YBCO) are described. Essential to the achieving high magnetic field resolution at low frequencies is the elimination of 1/f flux noise due to thermally activated hopping of flux vortices between pinning sites in the superconducting films. Through improvements in processing, 1/f noise in single layer YBCO thin films and YBCO-SrTiO3-YBCO trilayers was systematically reduced to allow fabrication of sensitive SQUID magnetometers. Both single-layer directly coupled SQUID magnetometers and multilayer magnetometers were fabricated, based on the dc SQUID with bicrystal grain boundary Josephson junctions. Multilayer magnetometers had a lower magnetic field noise for a given physical size due to greater effective sensing areas. A magnetometer consisting of a SQUID inductively coupled to the multiturn input coil of a flux transformer in a flip-chip arrangement had a field noise of 27 fT Hz-1/2 at 1 Hz and 8.5 fT Hz-1/2 at 1 kHz. A multiloop multilayer SQUID magnetometer had a field noise of 37 fT Hz-1/2 at 1 Hz and 18 fT Hz-1/2 at 1 kHz. A three-axis SQUID magnetometer for geophysical applications was constructed and operated in the field in the presence of 60 Hz and radiofrequency noise. Clinical quality magnetocardiograms were measured using multilayer SQUID magnetometers in a magnetically shielded room.

  13. Directly coupled YBCO dc SQUID magnetometers

    International Nuclear Information System (INIS)

    Petersen, P.R.E.; Shen, Y.Q.; Holst, T.; Larsen, B.H.; Sager, M.P.; Bindslev Hansen, J.

    1999-01-01

    YBa 2 Cu 3 O 7- x magnetometers have been made on 10mmx10mm MgO substrates by directly coupling the magnetometer pick-up loop to a dc SQUID with narrow strip lines. The dc SQUIDs were made with YBa 2 Cu 3 O 7-x step-edge Josephson junctions. The layout of the magnetometer pick-up loop was chosen as a compromise between maximizing the loop effective area and minimizing the loop inductance. The SQUID was designed to have L S ∼100 pH in order to obtain β L =2I 0 L S /Φ 0 approx.= 1 with the single-junction critical current I 0 ∼10 μA. We have made magnetometers with white noise levels down to 55 fT Hz -1/2 and a 1/f knee at 1 Hz (ac biased). Noise measurements were made on a field-cooled magnetometer. The noise measured at 1 Hz when cooled in 'zero field' was 175 fT Hz -1/2 . When cooled in magnetic fields of B = 50 μT and B = 100 μT we measured the noise at 1 Hz to be 430 fT Hz -1 2 and 1.3 pT Hz -1/2 , respectively. (author)

  14. Magnetoresistive magnetometer for space science applications

    International Nuclear Information System (INIS)

    Brown, P; Beek, T; Carr, C; O’Brien, H; Cupido, E; Oddy, T; Horbury, T S

    2012-01-01

    Measurement of the in situ dc magnetic field on space science missions is most commonly achieved using instruments based on fluxgate sensors. Fluxgates are robust, reliable and have considerable space heritage; however, their mass and volume are not optimized for deployment on nano or picosats. We describe a new magnetometer design demonstrating science measurement capability featuring significantly lower mass, volume and to a lesser extent power than a typical fluxgate. The instrument employs a sensor based on anisotropic magnetoresistance (AMR) achieving a noise floor of less than 50 pT Hz −1/2 above 1 Hz on a 5 V bridge bias. The instrument range is scalable up to ±50 000 nT and the three-axis sensor mass and volume are less than 10 g and 10 cm 3 , respectively. The ability to switch the polarization of the sensor's easy axis and apply magnetic feedback is used to build a driven first harmonic closed loop system featuring improved linearity, gain stability and compensation of the sensor offset. A number of potential geospace applications based on the initial instrument results are discussed including attitude control systems and scientific measurement of waves and structures in the terrestrial magnetosphere. A flight version of the AMR magnetometer will fly on the TRIO-CINEMA mission due to be launched in 2012. (paper)

  15. Observatory Magnetometer In-Situ Calibration

    Directory of Open Access Journals (Sweden)

    A Marusenkov

    2011-07-01

    Full Text Available An experimental validation of the in-situ calibration procedure, which allows estimating parameters of observatory magnetometers (scale factors, sensor misalignment without its operation interruption, is presented. In order to control the validity of the procedure, the records provided by two magnetometers calibrated independently in a coil system have been processed. The in-situ estimations of the parameters are in very good agreement with the values provided by the coil system calibration.

  16. Tuned optical cavity magnetometer

    Science.gov (United States)

    Okandan, Murat; Schwindt, Peter

    2010-11-02

    An atomic magnetometer is disclosed which utilizes an optical cavity formed from a grating and a mirror, with a vapor cell containing an alkali metal vapor located inside the optical cavity. Lasers are used to magnetically polarize the alkali metal vapor and to probe the vapor and generate a diffracted laser beam which can be used to sense a magnetic field. Electrostatic actuators can be used in the magnetometer for positioning of the mirror, or for modulation thereof. Another optical cavity can also be formed from the mirror and a second grating for sensing, adjusting, or stabilizing the position of the mirror.

  17. Attitude Determination with Magnetometers and Accelerometers to Use in Satellite Simulator

    Directory of Open Access Journals (Sweden)

    Helio Koiti Kuga

    2013-01-01

    Full Text Available Attitude control of artificial satellites is dependent on information provided by its attitude determination process. This paper presents the implementation and tests of a fully self-contained algorithm for the attitude determination using magnetometers and accelerometers, for application on a satellite simulator based on frictionless air bearing tables. However, it is known that magnetometers and accelerometers need to be calibrated so as to allow that measurements are used to their ultimate accuracy. A calibration method is implemented which proves to be essential for improving attitude determination accuracy. For the stepwise real-time attitude determination, it was used the well-known QUEST algorithm which yields quick response with reduced computer resources. The algorithms are tested and qualified with actual data collected on the streets under controlled situations. For such street runaways, the experiment employs a solid-state magnetoresistive magnetometer and an IMU navigation block consisting of triads of accelerometers and gyros, with MEMS technology. A GPS receiver is used to record positional information. The collected measurements are processed through the developed algorithms, and comparisons are made for attitude determination using calibrated and noncalibrated data. The results show that the attitude accuracy reaches the requirements for real-time operation for satellite simulator platforms.

  18. Development of a Micro-Fabricated Total-Field Magnetometer

    Science.gov (United States)

    2011-03-01

    are made with fluxgate technologies. Fluxgates have lower sensitivity than Cs magnetometers , yet they continue to be used in small wands simply...extraction process by providing the sensitivity of a Cs magnetometer with the convenience and low cost of a fluxgate wand. Extremely small and low cost...FINAL REPORT Development of a Micro-Fabricated Total-Field Magnetometer SERDP Project MR-1512 MARCH 2011 Mark Prouty Geometrics, Inc

  19. Optical Magnetometer Incorporating Photonic Crystals

    Science.gov (United States)

    Kulikov, Igor; Florescu, Lucia

    2007-01-01

    According to a proposal, photonic crystals would be used to greatly increase the sensitivities of optical magnetometers that are already regarded as ultrasensitive. The proposal applies, more specifically, to a state-of-the-art type of quantum coherent magnetometer that exploits the electromagnetically-induced-transparency (EIT) method for determining a small change in a magnetic field indirectly via measurement of the shift, induced by that change, in the hyperfine levels of resonant atoms exposed to the field.

  20. A game-theoretic approach for calibration of low-cost magnetometers under noise uncertainty

    Science.gov (United States)

    Siddharth, S.; Ali, A. S.; El-Sheimy, N.; Goodall, C. L.; Syed, Z. F.

    2012-02-01

    Pedestrian heading estimation is a fundamental challenge in Global Navigation Satellite System (GNSS)-denied environments. Additionally, the heading observability considerably degrades in low-speed mode of operation (e.g. walking), making this problem even more challenging. The goal of this work is to improve the heading solution when hand-held personal/portable devices, such as cell phones, are used for positioning and to improve the heading estimation in GNSS-denied signal environments. Most smart phones are now equipped with self-contained, low cost, small size and power-efficient sensors, such as magnetometers, gyroscopes and accelerometers. A magnetometer needs calibration before it can be properly employed for navigation purposes. Magnetometers play an important role in absolute heading estimation and are embedded in many smart phones. Before the users navigate with the phone, a calibration is invoked to ensure an improved signal quality. This signal is used later in the heading estimation. In most of the magnetometer-calibration approaches, the motion modes are seldom described to achieve a robust calibration. Also, suitable calibration approaches fail to discuss the stopping criteria for calibration. In this paper, the following three topics are discussed in detail that are important to achieve proper magnetometer-calibration results and in turn the most robust heading solution for the user while taking care of the device misalignment with respect to the user: (a) game-theoretic concepts to attain better filter parameter tuning and robustness in noise uncertainty, (b) best maneuvers with focus on 3D and 2D motion modes and related challenges and (c) investigation of the calibration termination criteria leveraging the calibration robustness and efficiency.

  1. A game-theoretic approach for calibration of low-cost magnetometers under noise uncertainty

    International Nuclear Information System (INIS)

    Siddharth, S; Ali, A S; El-Sheimy, N; Goodall, C L; Syed, Z F

    2012-01-01

    Pedestrian heading estimation is a fundamental challenge in Global Navigation Satellite System (GNSS)-denied environments. Additionally, the heading observability considerably degrades in low-speed mode of operation (e.g. walking), making this problem even more challenging. The goal of this work is to improve the heading solution when hand-held personal/portable devices, such as cell phones, are used for positioning and to improve the heading estimation in GNSS-denied signal environments. Most smart phones are now equipped with self-contained, low cost, small size and power-efficient sensors, such as magnetometers, gyroscopes and accelerometers. A magnetometer needs calibration before it can be properly employed for navigation purposes. Magnetometers play an important role in absolute heading estimation and are embedded in many smart phones. Before the users navigate with the phone, a calibration is invoked to ensure an improved signal quality. This signal is used later in the heading estimation. In most of the magnetometer-calibration approaches, the motion modes are seldom described to achieve a robust calibration. Also, suitable calibration approaches fail to discuss the stopping criteria for calibration. In this paper, the following three topics are discussed in detail that are important to achieve proper magnetometer-calibration results and in turn the most robust heading solution for the user while taking care of the device misalignment with respect to the user: (a) game-theoretic concepts to attain better filter parameter tuning and robustness in noise uncertainty, (b) best maneuvers with focus on 3D and 2D motion modes and related challenges and (c) investigation of the calibration termination criteria leveraging the calibration robustness and efficiency. (paper)

  2. THOR Fluxgate Magnetometer (MAG)

    Science.gov (United States)

    Nakamura, Rumi; Eastwood, Jonathan; Magnes, Werner; Carr, Christopher, M.; O'Brien, Helen, L.; Narita, Yasuhito; K, Chen, Christopher H.; Berghofer, Gerhard; Valavanoglou, Aris; Delva, Magda; Plaschke, Ferdinand; Cupido, Emanuele; Soucek, Jan

    2017-04-01

    Turbulence Heating ObserveR (THOR) is the first mission ever flown in space dedicated to plasma turbulence. The fluxgate Magnetometer (MAG) measures the background to low frequency magnetic field. The high sensitivity measurements of MAG enable to characterize the nature of turbulent fluctuations as well as the large-scale context. MAG will provide the reference system for determining anisotropy of field fluctuations, pitch-angle and gyro-phase of particles. The design of the magnetometer consists of two tri-axial sensors and the related magnetometer electronics; the electronics are hosted on printed circuit boards in the common electronics box of the fields and wave processor (FWP). A fully redundant two- sensor system mounted on a common boom and the new miniaturized low noise design based on MMS and Solar Orbiter instruments enable accurate measurement throughout the region of interest for THOR science. The usage of the common electronics hosted by FWP guarantees to fulfill the required timing accuracy with other fields measurements. These improvements are important to obtain precise measurements of magnetic field, which is essential to estimate basic plasma parameters and correctly identify the spatial and temporal scales of the turbulence. Furthermore, THOR MAG provides high quality data with sufficient overlap with the Search Coil Magnetometer (SCM) in frequency space to obtain full coverage of the wave forms over all the frequencies necessary to obtain the full solar wind turbulence spectrum from MHD to kinetic range with sufficient accuracy. We discuss the role of MAG in THOR key science questions and present the new developments during Phase A such as the finalised instrument design, MAG relevant requirement, and new calibraion schemes.

  3. Effect of second harmonic in pulse-width-modulation-based DAC for feedback of digital fluxgate magnetometer

    Science.gov (United States)

    Belyayev, Serhiy; Ivchenko, Nickolay

    2018-04-01

    Digital fluxgate magnetometers employ processing of the measured pickup signal to produce the value of the compensation current. Using pulse-width modulation with filtering for digital to analog conversion is a convenient approach, but it can introduce an intrinsic source of nonlinearity, which we discuss in this design note. A code shift of one least significant bit changes the second harmonic content of the pulse train, which feeds into the pick-up signal chain despite the heavy filtering. This effect produces a code-dependent nonlinearity. This nonlinearity can be overcome by the specific design of the timing of the pulse train signal. The second harmonic is suppressed if the first and third quarters of the excitation period pulse train are repeated in the second and fourth quarters. We demonstrate this principle on a digital magnetometer, achieving a magnetometer noise level corresponding to that of the sensor itself.

  4. Atomic magnetometer for human magnetoencephalograpy.

    Energy Technology Data Exchange (ETDEWEB)

    Schwindt, Peter; Johnson, Cort N.

    2010-12-01

    We have developed a high sensitivity (<5 fTesla/{radical}Hz), fiber-optically coupled magnetometer to detect magnetic fields produced by the human brain. This is the first demonstration of a noncryogenic sensor that could replace cryogenic superconducting quantum interference device (SQUID) magnetometers in magnetoencephalography (MEG) and is an important advance in realizing cost-effective MEG. Within the sensor, a rubidium vapor is optically pumped with 795 laser light while field-induced optical rotations are measured with 780 nm laser light. Both beams share a single optical axis to maximize simplicity and compactness. In collaboration with neuroscientists at The Mind Research Network in Albuquerque, NM, the evoked responses resulting from median nerve and auditory stimulation were recorded with the atomic magnetometer and a commercial SQUID-based MEG system with signals comparing favorably. Multi-sensor operation has been demonstrated with two AMs placed on opposite sides of the head. Straightforward miniaturization would enable high-density sensor arrays for whole-head magnetoencephalography.

  5. Evaluating Detection and Estimation Capabilities of Magnetometer-Based Vehicle Sensors

    Science.gov (United States)

    2012-05-01

    fluxgate magnetometers whose operating characteristics are well documented [1, 2]. Such magnetometers measure two perpendicular magnetic components of...of surveillance scenarios. As part of that work, this analysis focuses on UGS utilizing of two-axis fluxgate magnetometers . Two MOPs are 12 -60 -40 -20...Proceedings of the IEEE, 78(6):973–989, June 1990. [2] E. M. Billingsley and S. W. Billingsley. Fluxgate magnetometers . Proceedings of the IEEE, 5090(194

  6. Vector Magnetometer Application with Moving Carriers

    Directory of Open Access Journals (Sweden)

    Andrii Prystai

    2016-12-01

    Full Text Available In magnetic prospecting the aeromagnetic survey is a widespread method used for research in large territories or in the areas with difficult access (forests, swamps, shallow waters. At present, a new type of mobile carriers – remotely piloted vehicles or drones – is becoming very common. The drones supplied by magnetometer can be also used for underground utility location (for example, steel and concrete constructions, buried power cables, to name a few. For aeromagnetic survey, obtaining of 3-component magnetic field data gives higher processing precision, so the fluxgate magnetometers (FGM seem to be the most preferable by reason of low weight, noise, power consumption and costs. During movement of FGM fixed to a drone practically permanent attitude changes in the Earth’s magnetic field arises with corresponding changes of its projection at FGM axes. Also the electromagnetic interference from the drone motor and uncontrolled oscillations of drone and suspension are the factors which limit the magnetometer sensitivity level. Aroused because of this, signals significantly exceed the expected signals from a studied object and so should be removed by proper interference filtration and use of stabilized towed construction, as well as at data processing. To find the necessary resolution threshold of a drone-portable FGM, the modeling was made to estimate magnetic field value from a small sphere about 1 cm radius at the minimal altitude of drone flight and it was shown that such a small object can be reliably detected if the FGM noise level is less than 0.15 nT. Next requirement is the necessity to decrease as much as possible the FGM power consumption with retention of low noise level. Finally, because of drone movement, the broadening of a frequency range should be done. The LEMI-026 magnetometer was developed satisfying all requirements to the drone-mounted device. The field tests were successfully performed using two of LEMI-026

  7. The MAGSAT vector magnetometer: A precision fluxgate magnetometer for the measurement of the geomagnetic field

    Science.gov (United States)

    Acuna, M. H.; Scearce, C. S.; Seek, J.; Scheifele, J.

    1978-01-01

    A description of the precision triaxial fluxgate magnetometer to be flown aboard the MAGSAT spacecraft is presented. The instrument covers the range of + or - 64,000 nT with a resolution of + or - 0.5 nT, an intrinsic accuracy of + or - 0.001% of full scale and an angular alignment stability of the order of 2 seconds of arc. It was developed at NASA's Goddard Space Flight Center and represents the state-of-the-art in precision vector magnetometers developed for spaceflight use.

  8. A simple fluxgate magnetometer using amorphous alloys

    International Nuclear Information System (INIS)

    Ghatak, S.K.; Mitra, A.

    1992-01-01

    A simple fluxgate magnetometer is developed using low magnetostrictive ferromagnetic amorphous alloy acting as a sensing element. It uses the fact that the magnetization of sensing element symmetrically magnetized by a sinusoidal field contains even harmonic components in presence of dc signal field H and the amplitude of the second harmonic component of magnetization is proportional to H. The sensitivity and linearity of the magnetometer with signal field are studied for parallel configuration and the field ranging from 10 nT to 10 μT can be measured. The functioning of the magnetometer is demonstrated by studying the shielding and flux-trapping phenomena in high-Tc superconductor. (orig.)

  9. Battlefield Applications for the Polatomic 2000 Magnetometer/Gradiometer

    National Research Council Canada - National Science Library

    Kuhlman, G

    2002-01-01

    ... He(4) scalar magnetometer/gradiometer. A major innovation in the P-2000 helium magnetometer is the introduction of a laser pump source to replace the conventional RF discharge helium lamp used in the Navy AN/ASQ-81/208 MAD Set...

  10. Digital fluxgate magnetometer: design notes

    International Nuclear Information System (INIS)

    Belyayev, Serhiy; Ivchenko, Nickolay

    2015-01-01

    We presented an approach to understanding the performance of a fully digital fluxgate magnetometer. All elements of the design are important for the performance of the instrument, and the presence of the digital feed-back loop introduces certain peculiarities affecting the noise and dynamic performance of the instrument. Ultimately, the quantisation noise of the digital to analogue converter is found to dominate the noise of the current design, although noise shaping alleviates its effect to some extent. An example of magnetometer measurements on board a sounding rocket is presented, and ways to further improve the performance of the instrument are discussed. (paper)

  11. Digital fluxgate magnetometer: design notes

    Science.gov (United States)

    Belyayev, Serhiy; Ivchenko, Nickolay

    2015-12-01

    We presented an approach to understanding the performance of a fully digital fluxgate magnetometer. All elements of the design are important for the performance of the instrument, and the presence of the digital feed-back loop introduces certain peculiarities affecting the noise and dynamic performance of the instrument. Ultimately, the quantisation noise of the digital to analogue converter is found to dominate the noise of the current design, although noise shaping alleviates its effect to some extent. An example of magnetometer measurements on board a sounding rocket is presented, and ways to further improve the performance of the instrument are discussed.

  12. Digital fluxgate magnetometer for the "Astrid-2" satellite

    DEFF Research Database (Denmark)

    Pedersen, Erik Bøje; Primdahl, Fritz; Petersen, Jan Raagaard

    1999-01-01

    The design and performance of the Astrid-2 magnetometer are described. The magnetometer uses mathematical routines implemented by software for commercially available digital dignal processors to determine the magnetic field from the fluxgate sensor. The sensor is from the latest generation of amo...

  13. On the control of magnetic perturbing field onboard landers: the Magnetometer Protection program for the ESA ExoMars/Humboldt MSMO magnetometer experiment

    DEFF Research Database (Denmark)

    Menvielle, M.; Primdahl, Fritz; Brauer, Peter

    to planetary research. The major difficulty in implementing a magnetometer experiment onboard a lander is to achieve at acceptable costs a good Magnetometer Protection, namely to control the perturbing magnetic field generated by the lander during operations at the planetary surfa ce, so as to achieve...... scientific payload in the frame of the ESA ExoMars mission. Experience from previous missions constitutes the background for the MSMO Magnetometer Protection strategy. DC and AC lander generated magnetic perturbations are discussed, with particular attention to those related to solar generators. Emphasis...... and very resource consuming....

  14. Development of autonomous magnetometer rotorcraft for wide area assessment

    Energy Technology Data Exchange (ETDEWEB)

    Roelof Versteeg; Matt Anderson; Les Beard; Eric Corban; Darryl Curley; Jeff Gamey; Ross Johnson; Dwight Junkin; Mark McKay; Jared Salzmann; Mikhail Tchernychev; Suraj Unnikrishnan; Scott Vinson

    2010-04-01

    Large areas across the United States are potentially contaminated with UXO, with some ranges encompassing tens to hundreds of thousands of acres. Technologies are needed which will allow for cost effective wide area scanning with 1) near 100 % coverage and 2) near 100 % detection of subsurface ordnance or features indicative of subsurface ordnance. The current approach to wide area assessment is a multi-level one, in which medium - altitude fixed wing optical imaging is used for an initial site assessment. This assessment is followed with low altitude manned helicopter based magnetometry. Subsequent to this wide area assessment targeted surface investigations are performed using either towed geophysical sensor arrays or man portable sensors. In order to be an effective tool for small UXO detection, the sensing altitude for magnetic site investigations needs to be on the order of 1 – 3 meters. These altitude requirements mean that manned helicopter surveys will generally only be feasible in large, open and relatively flat terrains. While such surveys are effective in mapping large areas relatively fast there are substantial mobilization/demobilization, staffing and equipment costs associated with these surveys (resulting in costs of approximately $100-$150/acre). In addition, due to the low altitude there are substantial risks to pilots and equipment. Surface towed arrays provide high resolution maps but have other limitations, e.g. in their ability to navigate rough terrain effectively. There is thus a need for other systems which can be used for effective data collection. An UAV (Unmanned Aerial Vehicle) magnetometer platform is an obvious alternative. The motivation behind such a system is that it reduces risk to operators, is lower in initial and Operational and Maintenance (O&M) costs (and can thus potentially be applied to smaller sites) and has the potential of being more effective in terms of detection and possibly characterization (through the use of

  15. Testing the three axis magnetometer and gradiometer MOURA and data comparison on San Pablo de los Montes Observatory.

    Science.gov (United States)

    Belen Fernandez, Ana; Sanz, Ruy; Covisa, Pablo; Tordesillas, Jose Manuel; Diaz-Michelena, Marina

    2013-04-01

    obtained by SPT magnetometers. This is considered the last step prior to Mars in situ measurements. SPT employs for geomagnetic observations a fluxgate magnetometer FGE-Danish Meteorological Institute and a fluxgate vector magnetometer Geomag M390, both equipped with Overhauser effect magnetometers GSM90. The conditions into the rooms that contain these instruments are controlled. The equipments are situated on several pillars fixed strategically at Earth surface avoiding vibrations and other Earth movement that could affect measurement due to changes on the sensor position, the region is magnetically clean and the temperature variation is very low. Magnetic measurements are performed by MOURA for several days located on one of these pillars. These measurements are compared with SPT reference instrumentation with the aim to obtain a direct and very accurate evaluation of MOURA facing reference instrumentation. http://metnet.fmi.fi/index.php Development of miniaturized instrumentation for Planetary Exploration and its application to the Mars MetNet Precursor Mission. H. Guerrero et al. EGU General Assembly 2010, held 2-7 May, 2010 in Vienna, Austria, p.13330 Funaki, M.; Hirasawa, N.; and the Ant-Plane Group. Outline of a small unmanned aerial vehicle (Ant-Plane) designed for Antartic research. Polar Science 2008, 2, 129-142. M. Diaz-Michelena Sensors 2009, 9(4), 2271-2288

  16. Self-Compensating Excitation of Fluxgate Sensors for Space Magnetometers

    DEFF Research Database (Denmark)

    Cerman, Alec; Merayo, José M.G.; Brauer, Peter

    2008-01-01

    The paper presents design and implementation of the new self-compensating excitation circuitry to the new generation of high-precise space vector magnetometers. The application starts with complex study including design of new robust model of the non-linear inductor leading to investigation...... of the most crucial points, continuous by design of the self-compensating excitation unit and concludes with unit complex testing and application to the magnetometer. The application of the self-compensation of the excitation decreases temperature drift of the magnetometer offset caused by the temperature...

  17. Analysing Harmonic Motions with an iPhone's Magnetometer

    Science.gov (United States)

    Yavuz, Ahmet; Temiz, Burak Kagan

    2016-01-01

    In this paper, we propose an experiment for analysing harmonic motion using an iPhone's (or iPad's) magnetometer. This experiment consists of the detection of magnetic field variations obtained from an iPhone's magnetometer sensor. A graph of harmonic motion is directly displayed on the iPhone's screen using the "Sensor Kinetics"…

  18. High-sensitivity dc field magnetometer using nonlinear resonance magnetoelectric effect

    International Nuclear Information System (INIS)

    Burdin, D.A.; Chashin, D.V.; Ekonomov, N.A.; Fetisov, Y.K.; Stashkevich, A.A.

    2016-01-01

    The design and operation principle of dc field magnetometer using nonlinear resonance magnetoelectric effect in a ferromagnetic–piezoelectric structure are described. It is shown that under action of ac pumping magnetic field the structure generates the output voltage containing higher harmonics whose amplitudes depend on the dc magnetic field. Best performance of the device is obtained if the signal of the third harmonics is used for the dc field measurement. The sensitivity can be considerably (by approximately three orders of magnitude) increased if advantage is taken of the acoustic resonance of the structure at this frequency. There exists the optimal pumping field ensuring the highest sensitivity. Further increasing of this field expands the range of measurable dc fields at the expense of deteriorated sensitivity. The magnetometer fabricated on the basis of a planar langatate-Metglas structure had sensitivity up to ~1 V/Oe and allowed detection of the fields as low as ~10"−"5 Oe. - Highlights: • Operational principle and design of new type dc field magnetometer is described. • Magnetometer uses nonlinear magnetoelectric effect in a langatate-Metglas structure. • Magnetometer has sensitivity of ~1 V/Oe and detects fields as low as 10"−"5 Oe. • The proposed magnetometer can compete with well known fluxgate sensors.

  19. High-sensitivity dc field magnetometer using nonlinear resonance magnetoelectric effect

    Energy Technology Data Exchange (ETDEWEB)

    Burdin, D.A.; Chashin, D.V.; Ekonomov, N.A. [Moscow State University of Information Technologies, Radio Engineering and Electronics, Moscow (Russian Federation); Fetisov, Y.K., E-mail: fetisov@mirea.ru [Moscow State University of Information Technologies, Radio Engineering and Electronics, Moscow (Russian Federation); Stashkevich, A.A. [LSPM (CNRS-UPR 3407), Université Paris 13, Sorbonne Paris Cité, 93430 Villetaneuse (France)

    2016-05-01

    The design and operation principle of dc field magnetometer using nonlinear resonance magnetoelectric effect in a ferromagnetic–piezoelectric structure are described. It is shown that under action of ac pumping magnetic field the structure generates the output voltage containing higher harmonics whose amplitudes depend on the dc magnetic field. Best performance of the device is obtained if the signal of the third harmonics is used for the dc field measurement. The sensitivity can be considerably (by approximately three orders of magnitude) increased if advantage is taken of the acoustic resonance of the structure at this frequency. There exists the optimal pumping field ensuring the highest sensitivity. Further increasing of this field expands the range of measurable dc fields at the expense of deteriorated sensitivity. The magnetometer fabricated on the basis of a planar langatate-Metglas structure had sensitivity up to ~1 V/Oe and allowed detection of the fields as low as ~10{sup −5} Oe. - Highlights: • Operational principle and design of new type dc field magnetometer is described. • Magnetometer uses nonlinear magnetoelectric effect in a langatate-Metglas structure. • Magnetometer has sensitivity of ~1 V/Oe and detects fields as low as 10{sup −5} Oe. • The proposed magnetometer can compete with well known fluxgate sensors.

  20. High Accuracy Vector Helium Magnetometer

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed HAVHM instrument is a laser-pumped helium magnetometer with both triaxial vector and omnidirectional scalar measurement capabilities in a single...

  1. Design of a Low-Cost 2-Axes Fluxgate Magnetometer for Small Satellite Applications

    Directory of Open Access Journals (Sweden)

    Su-Jeoung Kim

    2005-03-01

    Full Text Available This paper addresses the design and analysis results of a 2-axes magnetometer for attitude determination of small satellite. A low-cost and efficient 2-axes fluxgate magnetometer was selected as the most suitable attitude sensor for LEO microsatellites which require a low-to-medium level pointing accuracy. An optimization trade-off study has been performed for the development of 2-axes fluxgate magnetometer. All the relevant parameters such as permeability, demagnetization factor, coil diameter, core thickness, and number of coil turns were considered for the sizing of a small satellite magnetometer. The magnetometer which is designed, manufactured, and tested in-house as described in this paper satisfies linearity requirement for determining attitude position of small satellites. On the basis of magnetometer which is designed in Space System Research Lab. (SSRL, commercial magnetometer will be developed.

  2. Search Coil vs. Fluxgate Magnetometer Measurements at Interplanetary Shocks

    Science.gov (United States)

    Wilson, L.B., III

    2012-01-01

    We present magnetic field observations at interplanetary shocks comparing two different sample rates showing significantly different results. Fluxgate magnetometer measurements show relatively laminar supercritical shock transitions at roughly 11 samples/s. Search coil magnetometer measurements at 1875 samples/s, however, show large amplitude (dB/B as large as 2) fluctuations that are not resolved by the fluxgate magnetometer. We show that these fluctuations, identified as whistler mode waves, would produce a significant perturbation to the shock transition region changing the interpretation from laminar to turbulent. Thus, previous observations of supercritical interplanetary shocks classified as laminar may have been under sampled.

  3. Induction Magnetometers – Design Peculiarities

    Directory of Open Access Journals (Sweden)

    Valeriy KOREPANOV

    2010-09-01

    Full Text Available Induction or search-coil magnetometers (IM are widely used in many branches of science and industry. The frequency range and dynamic range of IMs are probably the widest of all existing magnetometers: they are used for the measurement of magnetic field variations in the frequency band from ~10-4 till ~106 Hz with the intensities from fractions of femtotesla till tens of tesla. This explains the permanent interest to IM design and the attempts to construct the IMs with best possible parameters. The present paper deals with the peculiarities of IM design. An attempt to re-establish the correctness of priorities in the field is made and the approaches to the IM optimization and their quality estimation are described.

  4. Preliminary Report: DESiGN and Test Result of KSR-3 Rocket Magnetometers

    Directory of Open Access Journals (Sweden)

    Hyo-Min Kim

    2000-12-01

    Full Text Available The solar wind contributes to the formation of unique space environment called the Earth's magnetosphere by various interactions with the Earth's magnetic field. Thus the solar-terrestrial environment affects the Earth's magnetic field, which can be observed with an instrument for the magnetic field measurement, the magnetometer usually mounted on the rocket and the satellite and based on the ground observatory. The magnetometer is a useful instrument for the spacecraft attitude control as well as the Earth's magnetic field measurements for a scientific purpose. In this paper, we present the preliminary design and test results of the two onboard magnetometers of KARI's (Korea Aerospace Research Institute sounding rocket, KSR-3, which will be launched four times during the period of 2001-02. The KSR-3 magnetometers consist of the fluxgate magnetometer, MAG/AIM (Attitude Information Magnetometer for acquiring the rocket flight attitude information, and of the search-coil magnetometer, MAG/SIM (Scientific Investigation Magnetometer for the observation of the Earth's magnetic field fluctuations. With the MAG/AIM, the 3-axis attitude information can be acquired by the comparison of the resulting dc magnetic vector field with the IGRF (International Geomagnetic Reference Field. The Earth's magnetic field fluctuations ranging from 10 to 1,000 Hz can also be observed with the MAG/SIM measurement.

  5. Ultra-sensitive Magnetic Microscopy with an Atomic Magnetometer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Jin [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-08-19

    The PowerPoint presentation focused on research goals, specific information about the atomic magnetometer, response and resolution factors of the SERF magnetometer, FC+AM systems, tests of field transfer and resolution on FC, gradient cancellation, testing of AM performance, ideas for a multi-channel AM, including preliminary sensitivity testing, and a description of a 6 channel DAQ system. A few ideas for future work ended the presentation.

  6. Analysing harmonic motions with an iPhone’s magnetometer

    Science.gov (United States)

    Yavuz, Ahmet; Kağan Temiz, Burak

    2016-05-01

    In this paper, we propose an experiment for analysing harmonic motion using an iPhone’s (or iPad’s) magnetometer. This experiment consists of the detection of magnetic field variations obtained from an iPhone’s magnetometer sensor. A graph of harmonic motion is directly displayed on the iPhone’s screen using the Sensor Kinetics application. Data from this application was analysed with Eureqa software to establish the equation of the harmonic motion. Analyses show that the use of an iPhone’s magnetometer to analyse harmonic motion is a practical and effective method for small oscillations and frequencies less than 15-20 Hz.

  7. Correlation between fluxgate and SQUID magnetometer data sets for geomagnetic storms

    Directory of Open Access Journals (Sweden)

    Matladi Thabang

    2014-01-01

    Full Text Available There has always been a need to monitor the near Earth's magnetic field, as this monitoring provides understanding and possible predictions of Space Weather events such as geomagnetic storms. Conventional magnetometers such as fluxgates have been used for decades for Space Weather research. The use of highly sensitive magnetometers such as Superconducting QUantum Interference Devices (SQUIDs, promise to give more insight into Space Weather. SQUIDs are relatively recent types of magnetometers that exploit the superconductive effects of flux quantization and Josephson tunneling to measure magnetic flux. SQUIDs have a very broad bandwidth compared to most conventional magnetometers and can measure magnetic flux as low as a few femtotesla. Since SQUIDs have never been used in Space Weather research, unshielded, it is necessary to investigate if they can be reliable Space Weather instruments. The validation is performed by comparing the frequency content of the SQUID and fluxgate magnetometers, as reported by Phiri.

  8. Calibration of a fluxgate magnetometer array and its application in magnetic object localization

    International Nuclear Information System (INIS)

    Pang, Hongfeng; Luo, Shitu; Zhang, Qi; Li, Ji; Chen, Dixiang; Pan, Mengchun; Luo, Feilu

    2013-01-01

    The magnetometer array is effective for magnetic object detection and localization. Calibration is important to improve the accuracy of the magnetometer array. A magnetic sensor array built with four three-axis DM-050 fluxgate magnetometers is designed, which is connected by a cross aluminum frame. In order to improve the accuracy of the magnetometer array, a calibration process is presented. The calibration process includes magnetometer calibration, coordinate transformation and misalignment calibration. The calibration system consists of a magnetic sensor array, a GSM-19T proton magnetometer, a two-dimensional nonmagnetic rotation platform, a 12 V-dc portable power device and two portable computers. After magnetometer calibration, the RMS error has been decreased from an original value of 125.559 nT to a final value of 1.711 nT (a factor of 74). After alignment, the RMS error of misalignment has been decreased from 1322.3 to 6.0 nT (a factor of 220). Then, the calibrated array deployed on the nonmagnetic rotation platform is used for ferromagnetic object localization. Experimental results show that the estimated errors of X, Y and Z axes are −0.049 m, 0.008 m and 0.025 m, respectively. Thus, the magnetometer array is effective for magnetic object detection and localization in three dimensions. (paper)

  9. Calibration of a fluxgate magnetometer array and its application in magnetic object localization

    Science.gov (United States)

    Pang, Hongfeng; Luo, Shitu; Zhang, Qi; Li, Ji; Chen, Dixiang; Pan, Mengchun; Luo, Feilu

    2013-07-01

    The magnetometer array is effective for magnetic object detection and localization. Calibration is important to improve the accuracy of the magnetometer array. A magnetic sensor array built with four three-axis DM-050 fluxgate magnetometers is designed, which is connected by a cross aluminum frame. In order to improve the accuracy of the magnetometer array, a calibration process is presented. The calibration process includes magnetometer calibration, coordinate transformation and misalignment calibration. The calibration system consists of a magnetic sensor array, a GSM-19T proton magnetometer, a two-dimensional nonmagnetic rotation platform, a 12 V-dc portable power device and two portable computers. After magnetometer calibration, the RMS error has been decreased from an original value of 125.559 nT to a final value of 1.711 nT (a factor of 74). After alignment, the RMS error of misalignment has been decreased from 1322.3 to 6.0 nT (a factor of 220). Then, the calibrated array deployed on the nonmagnetic rotation platform is used for ferromagnetic object localization. Experimental results show that the estimated errors of X, Y and Z axes are -0.049 m, 0.008 m and 0.025 m, respectively. Thus, the magnetometer array is effective for magnetic object detection and localization in three dimensions.

  10. Calibration of the Ørsted vector magnetometer

    DEFF Research Database (Denmark)

    Olsen, Nils; Tøffner-Clausen, Lars; Sabaka, T.J.

    2003-01-01

    The vector fluxgate magnetometer of the Orsted satellite is routinely calibrated by comparing its output with measurements of the absolute magnetic intensity from the Overhauser instrument, which is the second magnetometer of the satellite. We describe the method used for and the result obtained...... coordinate system and the reference system of the star imager. This is done by comparing the magnetic and attitude measurements with a model of Earth's magnetic field. The Euler angles describing this rotation are determined in this way with an accuracy of better than 4 arcsec....

  11. NetPICOmag: A low-cost networked magnetometer and its applications

    Science.gov (United States)

    Schofield, I.; Connors, M.; Russell, C. T.

    2012-03-01

    NetPICOmag (NPM) is the culmination of a design effort to build a compact, low-cost, laboratory-grade, networked magnetometer designed for remote autonomous operation, suited for research and education. NPM allows wide placement of magnetometers sensitive enough to detect auroral activity and the daily variation, and is suitable for education projects and a range of geophysical applications. The use of networked microcontrollers and GPS timing is applicable to other small instruments for field or local deployment, and an onboard data logging capability has also been demonstrated. We illustrate the value of the placement of low-cost magnetometers to increase coverage in an area through the study of a Pc 5 pulsation event which took place on September 4, 2010. By combining results with those from auroral zone magnetometers supporting the THEMIS project, we find that the phase velocity of these morning sector pulsations was northward on the ground. The event took place under very quiet solar wind conditions, and credible mapping associates it with the inner magnetosphere. Another aspect beyond increasing areal coverage is increasing density of coverage, which becomes feasible with instruments of very low cost. We examine aspects of the April 5, 2010 space weather event which are possible to deduce from closely spaced magnetometers.

  12. Developement of a Fluxgate Magnetometer for the KITSAT-3 Satellite

    Directory of Open Access Journals (Sweden)

    S. H. Hwang

    1997-12-01

    Full Text Available The magnetometer is one of the most important payloads of scientific satellites to monitor the near-earth space environment. The electromagnetic variations of the space environment can be observed with the electric and magnetic field measurements. In practice, it is well known that the measurement of magnetic fields needs less technical complexities than that of electric fields in space. Therefore the magnetometer has long been recognized as one of the basic payloads for the scientific satellites. In this paper, we discuss the scientific fluxgate magnetometer which will be on board the KITSAT-3. The main circuit design of the present magnetometer is based on that of KISAT-1 and -2 but its facilities have been re-designed to improve the resolution to about 5nT for scientific purpose. The calibration and noise level test of this circuit have been performed at the laboratory of the Tierra Tecnica company in Japan.

  13. Differential Search Coils Based Magnetometers: Conditioning, Magnetic Sensitivity, Spatial Resolution

    Directory of Open Access Journals (Sweden)

    Timofeeva Maria

    2012-03-01

    Full Text Available A theoretical and experimental comparison of optimized search coils based magnetometers, operating either in the Flux mode or in the classical Lenz-Faraday mode, is presented. The improvements provided by the Flux mode in terms of bandwidth and measuring range of the sensor are detailed. Theory, SPICE model and measurements are in good agreement. The spatial resolution of the sensor is studied which is an important parameter for applications in non destructive evaluation. A general expression of the magnetic sensitivity of search coils sensors is derived. Solutions are proposed to design magnetometers with reduced weight and volume without degrading the magnetic sensitivity. An original differential search coil based magnetometer, made of coupled coils, operating in flux mode and connected to a differential transimpedance amplifier is proposed. It is shown that this structure is better in terms of volume occupancy than magnetometers using two separated coils without any degradation in magnetic sensitivity. Experimental results are in good agreement with calculations.

  14. Design and analysis of miniature tri-axial fluxgate magnetometer

    Science.gov (United States)

    Zhi, Menghui; Tang, Liang; Qiao, Donghai

    2017-02-01

    The detection technology of weak magnetic field is widely used in Earth resource survey and geomagnetic navigation. Useful magnetic field information can be obtained by processing and analyzing the measurement data from magnetic sensors. A miniature tri-axial fluxgate magnetometer is proposed in this paper. This miniature tri-axial fluxgate magnetometer with ring-core structure has a dynamic range of the Earth’s field ±65,000 nT, resolution of several nT. It has three independent parts placed in three perpendicular planes for measuring three orthogonal magnetic field components, respectively. A field-programmable gate array (FPGA) is used to generate stimulation signal, analog-to-digital (A/D) convertor control signal, and feedback digital-to-analog (D/A) control signal. Design and analysis details are given to improve the dynamic range, sensitivity, resolution, and linearity. Our prototype was measured and compared with a commercial standard Magson fluxgate magnetometer as a reference. The results show that our miniature fluxgate magnetometer can follow the Magson’s change trend well. When used as a magnetic compass, our prototype only has ± 0.3∘ deviation compared with standard magnetic compass.

  15. All optical vector magnetometer, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase I research project will investigate a novel method of operating an atomic magnetometer to simultaneously measure total magnetic fields and vector magnetic...

  16. Sensitivity optimization of Bell-Bloom magnetometers by manipulation of atomic spin synchronization

    Science.gov (United States)

    Ranjbaran, M.; Tehranchi, M. M.; Hamidi, S. M.; Khalkhali, S. M. H.

    2018-05-01

    Many efforts have been devoted to the developments of atomic magnetometers for achieving the high sensitivity required in biomagnetic applications. To reach the high sensitivity, many types of atomic magnetometers have been introduced for optimization of the creation and relaxation rates of atomic spin polarization. In this paper, regards to sensitivity optimization techniques in the Mx configuration, we have proposed a novelty approach for synchronization of the spin precession in the Bell-Bloom magnetometers. We have utilized the phenomenological Bloch equations to simulate the spin dynamics when modulation of pumping light and radio frequency magnetic field were both used for atomic spin synchronization. Our results showed that the synchronization process, improved the magnetometer sensitivity respect to the classical configurations.

  17. New Magneto-Inductive DC Magnetometer for Space Missions

    Science.gov (United States)

    Moldwin, M.; Bronner, B.; Regoli, L.; Thoma, J.; Shen, A.; Jenkins, G.; Cutler, J.

    2017-12-01

    A new magneto-inductive DC magnetometer is being developed at the University of Michigan that provides fluxgate quality measurements in a low mass, volume, power and cost package. The magnetometer enables constellation-class missions not only due to its low-resource requirements, but also its potential for commercial integrated circuit fabrication. The magneto-inductive operating principle is based on a simple resistance-inductor (RL) circuit and involves measurement of the time it takes to charge and discharge the inductor between an upper and lower threshold by means of a Schmitt trigger oscillator. This time is proportional to the inductance that in turn is proportional to the field strength. We have modeled the operating principle in the circuit simulator SPICE and have built a proto-type using modified commercial sensors. The performance specifications include a dynamic range over the full-Earth's field, sampling rates up to 80 Hz, sensor and electronics mass of about 30 g, circuit board and sensor housing volume of magnetometer.

  18. A spinner magnetometer for large Apollo lunar samples

    Science.gov (United States)

    Uehara, M.; Gattacceca, J.; Quesnel, Y.; Lepaulard, C.; Lima, E. A.; Manfredi, M.; Rochette, P.

    2017-10-01

    We developed a spinner magnetometer to measure the natural remanent magnetization of large Apollo lunar rocks in the storage vault of the Lunar Sample Laboratory Facility (LSLF) of NASA. The magnetometer mainly consists of a commercially available three-axial fluxgate sensor and a hand-rotating sample table with an optical encoder recording the rotation angles. The distance between the sample and the sensor is adjustable according to the sample size and magnetization intensity. The sensor and the sample are placed in a two-layer mu-metal shield to measure the sample natural remanent magnetization. The magnetic signals are acquired together with the rotation angle to obtain stacking of the measured signals over multiple revolutions. The developed magnetometer has a sensitivity of 5 × 10-7 Am2 at the standard sensor-to-sample distance of 15 cm. This sensitivity is sufficient to measure the natural remanent magnetization of almost all the lunar basalt and breccia samples with mass above 10 g in the LSLF vault.

  19. A spinner magnetometer for large Apollo lunar samples.

    Science.gov (United States)

    Uehara, M; Gattacceca, J; Quesnel, Y; Lepaulard, C; Lima, E A; Manfredi, M; Rochette, P

    2017-10-01

    We developed a spinner magnetometer to measure the natural remanent magnetization of large Apollo lunar rocks in the storage vault of the Lunar Sample Laboratory Facility (LSLF) of NASA. The magnetometer mainly consists of a commercially available three-axial fluxgate sensor and a hand-rotating sample table with an optical encoder recording the rotation angles. The distance between the sample and the sensor is adjustable according to the sample size and magnetization intensity. The sensor and the sample are placed in a two-layer mu-metal shield to measure the sample natural remanent magnetization. The magnetic signals are acquired together with the rotation angle to obtain stacking of the measured signals over multiple revolutions. The developed magnetometer has a sensitivity of 5 × 10 -7 Am 2 at the standard sensor-to-sample distance of 15 cm. This sensitivity is sufficient to measure the natural remanent magnetization of almost all the lunar basalt and breccia samples with mass above 10 g in the LSLF vault.

  20. A portable Hall magnetometer probe for characterization of magnetic iron oxide nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, Jefferson F.D.F.; Costa, Mateus C.; Louro, Sonia R.W.; Bruno, Antonio C., E-mail: acbruno@puc-rio.br

    2017-03-15

    We have built a portable Hall magnetometer probe, for measuring magnetic properties of iron oxide nanoparticles, that can be used for bulk materials and liquid samples as well. The magnetometer probe consists of four voltage-programmable commercial Hall sensors and a thin acrylic plate for positioning the sensors. In order to operate, it needs to be attached to a pole of an electromagnet and connected to an AD converter and a computer. It acquires a complete magnetization curve in a couple of minutes and has a magnetic moment sensitivity of 3.5×10{sup −7} Am{sup 2}. We tested its performance with magnetic nanoparticles containing an iron oxide core and having coating layers with different sizes. The magnetization results obtained were compared with measurements performed on commercial stand-alone magnetometers, and exhibited errors of about ±0.2 Am{sup 2}/kg (i.e 0.4%) at saturation and below 0.5 Am{sup 2}/kg (i.e. 10%) at remanence. - Highlights: • A low-cost portable Hall magnetometer probe has been built. • The Hall magnetometer probe can be attached to any electromagnet. • The Hall probe was calibrated and successfully compared to industry standard magnetometers. • The Hall probe was able to measure iron oxide nanoparticles with different coatings.

  1. A portable Hall magnetometer probe for characterization of magnetic iron oxide nanoparticles

    International Nuclear Information System (INIS)

    Araujo, Jefferson F.D.F.; Costa, Mateus C.; Louro, Sonia R.W.; Bruno, Antonio C.

    2017-01-01

    We have built a portable Hall magnetometer probe, for measuring magnetic properties of iron oxide nanoparticles, that can be used for bulk materials and liquid samples as well. The magnetometer probe consists of four voltage-programmable commercial Hall sensors and a thin acrylic plate for positioning the sensors. In order to operate, it needs to be attached to a pole of an electromagnet and connected to an AD converter and a computer. It acquires a complete magnetization curve in a couple of minutes and has a magnetic moment sensitivity of 3.5×10 −7 Am 2 . We tested its performance with magnetic nanoparticles containing an iron oxide core and having coating layers with different sizes. The magnetization results obtained were compared with measurements performed on commercial stand-alone magnetometers, and exhibited errors of about ±0.2 Am 2 /kg (i.e 0.4%) at saturation and below 0.5 Am 2 /kg (i.e. 10%) at remanence. - Highlights: • A low-cost portable Hall magnetometer probe has been built. • The Hall magnetometer probe can be attached to any electromagnet. • The Hall probe was calibrated and successfully compared to industry standard magnetometers. • The Hall probe was able to measure iron oxide nanoparticles with different coatings.

  2. An Arduino-Based Magnetometer

    Science.gov (United States)

    McCaughey, Mike

    2017-01-01

    An Arduino-based system with a triple axis magnetometer chip may be used to plot both the strength and direction of the magnetic field of a magnet directly on a sheet of paper. Before taking measurements, it is necessary either to correct for or to eliminate soft and hard iron effects. The same sensor may be used to determine the presence of soft…

  3. Midlatitude magnetometer chains during the IMS

    International Nuclear Information System (INIS)

    Mcpherron, R.L.

    1982-01-01

    The International Magnetospheric Study (IMS) is an international program to study global problems of magnetospheric dynamics. A key element of the U.S. participation in this program was the establishment of a ground magnetometer network. This network included a number of arrays at high and low latitudes. This report describes three chains established at midlatitudes, including the IMS Midlatitude Chain, the AFGL Magnetometer Network, and the Bell Lab Conjugate Array. Descriptions of the type of equipment, station locations, types of data display, and availability of data for each chain are presented in this report. A major problem of the data analysis phase of the IMS will be reducing selected subsets of these data to a common format. Currently, there are no plans to do this in a systematic manner

  4. Design Principles of A Sigma-delta Flux-gate Magnetometer

    Science.gov (United States)

    Magnes, W.; Valavanoglou, A.; Pierce, D.; Frank, A.; Schwingenschuh, K.

    A state-of-the-art flux-gate magnetometer is characterised by magnetic field resolution of several pT in a wide frequency range, low power consumption, low weight and high robustness. Therefore, flux-gate magnetometers are frequently used for ground-based Earth's field observation as well as for measurements aboard scientific space missions. But both traditional analogue and recently developed digital flux-gate magnetometers need low power and high-resolution analogue-to-digital converters for signal quan- tization. The disadvantage of such converters is the low radiation hardness. This fact has led to the idea of combining a traditional analogue flux-gate regulation circuit with that of a discretely realized sigma-delta converter in order to get a radiation hard and further miniaturized magnetometer. The name sigma-delta converter is derived from putting an integrator in front of a 1-bit delta modulator which forms the sigma-delta loop. It is followed by a digital decimation filter realized in a field-programmable gate array (FPGA). The flux-gate regulation and the sigma-delta loop are quite similar in the way of realizing the integrator and feedback circuit, which makes it easy to com- bine these two systems. The presented talk deals with the design principles and the results of a first bread board model.

  5. Microfabricated optically pumped magnetometer arrays for biomedical imaging

    Science.gov (United States)

    Perry, A. R.; Sheng, D.; Krzyzewski, S. P.; Geller, S.; Knappe, S.

    2017-02-01

    Optically-pumped magnetometers have demonstrated magnetic field measurements as precise as the best superconducting quantum interference device magnetometers. Our group develops miniature alkali atom-based magnetic sensors using microfabrication technology. Our sensors do not require cryogenic cooling, and can be positioned very close to the sample, making these sensors an attractive option for development in the medical community. We will present our latest chip-scale optically-pumped gradiometer developed for array applications to image magnetic fields from the brain noninvasively. These developments should lead to improved spatial resolution, and potentially sensitive measurements in unshielded environments.

  6. A dumbbell-shaped hybrid magnetometer operating in DC-10 kHz

    Science.gov (United States)

    Shi, Hongyu; Wang, Yanzhang; Chen, Siyu; Lin, Jun

    2017-12-01

    This study is motivated by the need to design a hybrid magnetometer operating in a wide-frequency band from DC to 10 kHz. To achieve this objective, a residence times difference fluxgate magnetometer (RTDFM) and an induction magnetometer (IM) have been integrated into a compact form. The hybrid magnetometer has a dumbbell-shaped structure in which the RTDFM transducer is partially inserted into the tube cores of the IM. Thus, the sensitivity of the RTDFM is significantly improved due to the flux amplification. The optimal structure, which has maximum sensitivity enhancement, was obtained through FEM analysis. To validate the theoretical analysis, the optimal hybrid magnetometer was manufactured, and its performance was evaluated. The device has a sensitivity of 45 mV/nT at 1 kHz in IM mode and 0.38 μs/nT in RTDFM mode, which is approximately 3.45 times as large as that of the single RTDFM structure. Furthermore, to obtain a lower noise performance in the entire frequency band, two operation modes switch at the cross frequency (0.16 Hz) of their noise levels. The noise level is 30 pT/√Hz in RTDFM mode and 0.07 pT/√Hz at 1 kHz in IM mode.

  7. DSCOVR Magnetometer Level 2 One Minute Averages

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Interplanetary magnetic field observations collected from magnetometer on DSCOVR satellite - 1-minute average of Level 1 data

  8. DSCOVR Magnetometer Level 2 One Second Averages

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Interplanetary magnetic field observations collected from magnetometer on DSCOVR satellite - 1-second average of Level 1 data

  9. Studies of Polar Current Systems Using the IMS Scandinavian Magnetometer Array

    Science.gov (United States)

    Untiedt, J.; Baumjohann, W.

    1993-09-01

    As a contribution to the International Magnetospheric Study (IMS, 1976 1979) a two-dimensional array of 42 temporary magnetometer stations was run in Scandinavia, supplementary to the permanent observatories and concentrated in the northern part of the region. This effort aimed at the time-dependent (periods above about 100 s) determination of the two-dimensional structure of substorm-related magnetic fields at the Earth's surface with highest reasonable spatial resolution (about 100 km, corresponding to the height of the ionosphere) near the footpoints of field-aligned electric currents that couple the disturbed magnetosphere to the ionosphere at auroral latitudes. It has been of particular advantage for cooperative studies that not only simultaneous data were available from all-sky cameras, riometers, balloons, rockets, and satellites, but also from the STARE radar facility yielding colocated two-dimensional ionospheric electric field distributions. In many cases it therefore was possible to infer the three-dimensional regional structure of substorm-related ionospheric current systems. The first part of this review outlines the basic relationships and methods that have been used or have been developed for such studies. The second short part presents typical equivalent current patterns observed by the magnetometer array in the course of substorms. Finally we review main results of studies that have been based on the magnetometer array observations and on additional data, omitting studies on geomagnetic pulsations. These studies contributed to a clarification of the nature of auroral electrojets including the Harang discontinuity and of ionospheric current systems related to auroral features such as the break-up at midnight, the westward traveling surge, eastward drifting omega bands, and spirals.

  10. Through-barrier electromagnetic imaging with an atomic magnetometer.

    Science.gov (United States)

    Deans, Cameron; Marmugi, Luca; Renzoni, Ferruccio

    2017-07-24

    We demonstrate the penetration of thick metallic and ferromagnetic barriers for imaging of conductive targets underneath. Our system is based on an 85 Rb radio-frequency atomic magnetometer operating in electromagnetic induction imaging modality in an unshielded environment. Detrimental effects, including unpredictable magnetic signatures from ferromagnetic screens and variations in the magnetic background, are automatically compensated by active compensation coils controlled by servo loops. We exploit the tunability and low-frequency sensitivity of the atomic magnetometer to directly image multiple conductive targets concealed by a 2.5 mm ferromagnetic steel shield and/or a 2.0 mm aluminium shield, in a single scan. The performance of the atomic magnetometer allows imaging without any prior knowledge of the barriers or the targets, and without the need of background subtraction. A dedicated edge detection algorithm allows automatic estimation of the targets' size within 3.3 mm and of their position within 2.4 mm. Our results prove the feasibility of a compact, sensitive and automated sensing platform for imaging of concealed objects in a range of applications, from security screening to search and rescue.

  11. Determination of the Overhauser magnetometer uncertainty

    Czech Academy of Sciences Publication Activity Database

    Ulvr, M.; Zikmund, A.; Kupec, J.; Janošek, M.; Vlk, Michal; Bayer, Tomáš

    2015-01-01

    Roč. 66, 7/s (2015), s. 26-29 ISSN 1335-3632 Institutional support: RVO:67985530 Keywords : Overhauser magnetometer * Earth `s magnetic field * comparison * uncertainty Subject RIV: DE - Earth Magnetism, Geodesy, Geography Impact factor: 0.407, year: 2015

  12. A theoretical and experimental investigation of the proton magnetometer

    International Nuclear Information System (INIS)

    Hancke, G.P.

    1987-01-01

    This study comprises the investigation of the properties of the proton magnetometer based on the free precession of protons. The basic principle of the free precession of protons in the earth's magnetic field is described and the most important factors affecting this free precession are examined. It is shown that very important parameters to keep in mind are the polarization time and the magnitude of the polarization field. A discussion of the errors of a proton magnetometer built on the periodometer principles is given and it is shown that the error in counting of the number of precession periods during the time of measurement contributes most to the total error. The magnitude of this error depends on the signal-to-noise ratio, the instability of the operating threshold of the discriminator of the period counter, it's operating time and the tuning accuracy of the sensor to the precession frequency. The penetration to a magnetometer input of variable magnetic and electric interferences, their influence on the phase of the useful signal, and the resulting measurement errors are examined and methods of reducing the effects of interferences are discussed. The optimization of sensor design is very important in the development of proton magnetometers. The coil geometry, physical size, the working substance and the polarization design are important parameters. The selection of a method for processing the precession signal of a proton magnetometer is examined, given a sensor and signal amplifier with fixed parameters. A method is proposed and compared with known methods. Measurement errors are computed for various signal-to-noise ratios and times of observation of the precession signal, and it is shown that the proposed method is superior to conventional methods found in commercial instruments

  13. Cryostats for SQUID magnetometers

    International Nuclear Information System (INIS)

    Testard, O.A.; Locatelli, M.

    1982-05-01

    A non metallic and non magnetic cryostat, with a very low thermal budget and a container type autonomy was developed, to condition S.Q.U.I.D. magnetometers which maximum sensitivity reaches 10 -14 Tesla Hertzsup(-1/2). This instrumentation puts in hand new concepts of composite materials, thermal shock and vibration resistant, multilayer thermal radiative insulation also to the prouve of vibrations with thermal equivalent emissivity lower than 10 -3

  14. Design and implementation of JOM-3 Overhauser magnetometer analog circuit

    Science.gov (United States)

    Zhang, Xiao; Jiang, Xue; Zhao, Jianchang; Zhang, Shuang; Guo, Xin; Zhou, Tingting

    2017-09-01

    Overhauser magnetometer, a kind of static-magnetic measurement system based on the Overhauser effect, has been widely used in archaeological exploration, mineral resources exploration, oil and gas basin structure detection, prediction of engineering exploration environment, earthquakes and volcanic eruotions, object magnetic measurement and underground buried booty exploration. Overhauser magnetometer plays an important role in the application of magnetic field measurement for its characteristics of small size, low power consumption and high sensitivity. This paper researches the design and the application of the analog circuit of JOM-3 Overhauser magnetometer. First, the Larmor signal output by the probe is very weak. In order to obtain the signal with high signal to noise rstio(SNR), the design of pre-amplifier circuit is the key to improve the quality of the system signal. Second, in this paper, the effectual step which could improve the frequency characters of bandpass filter amplifier circuit were put forward, and theoretical analysis was made for it. Third, the shaping circuit shapes the amplified sine signal into a square wave signal which is suitable for detecting the rising edge. Fourth, this design elaborated the optimized choice of tuning circuit, so the measurement range of the magnetic field can be covered. Last, integrated analog circuit testing system was formed to detect waveform of each module. By calculating the standard deviation, the sensitivity of the improved Overhauser magnetometer is 0.047nT for Earth's magnetic field observation. Experimental results show that the new magnetometer is sensitive to earth field measurement.

  15. Field-Programmable Gate Array-based fluxgate magnetometer with digital integration

    Science.gov (United States)

    Butta, Mattia; Janosek, Michal; Ripka, Pavel

    2010-05-01

    In this paper, a digital magnetometer based on printed circuit board fluxgate is presented. The fluxgate is pulse excited and the signal is extracted by gate integration. We investigate the possibility to perform integration on very narrow gates (typically 500 ns) by using digital techniques. The magnetometer is based on field-programmable gate array (FPGA) card: we will show all the advantages and disadvantages, given by digitalization of fluxgate output voltage by means of analog-to-digital converter on FPGA card, as well as digitalization performed by external digitizer. Due to very narrow gate, it is shown that a magnetometer entirely based on a FPGA card is preferable, because it avoids noise due to trigger instability. Both open loop and feedback operative mode are described and achieved results are presented.

  16. A Web Server for MACCS Magnetometer Data

    Science.gov (United States)

    Engebretson, Mark J.

    1998-01-01

    NASA Grant NAG5-3719 was provided to Augsburg College to support the development of a web server for the Magnetometer Array for Cusp and Cleft Studies (MACCS), a two-dimensional array of fluxgate magnetometers located at cusp latitudes in Arctic Canada. MACCS was developed as part of the National Science Foundation's GEM (Geospace Environment Modeling) Program, which was designed in part to complement NASA's Global Geospace Science programs during the decade of the 1990s. This report describes the successful use of these grant funds to support a working web page that provides both daily plots and file access to any user accessing the worldwide web. The MACCS home page can be accessed at http://space.augsburg.edu/space/MaccsHome.html.

  17. Nonlinear temperature compensation of fluxgate magnetometers with a least-squares support vector machine

    International Nuclear Information System (INIS)

    Pang, Hongfeng; Chen, Dixiang; Pan, Mengchun; Luo, Shitu; Zhang, Qi; Luo, Feilu

    2012-01-01

    Fluxgate magnetometers are widely used for magnetic field measurement. However, their accuracy is influenced by temperature. In this paper, a new method was proposed to compensate the temperature drift of fluxgate magnetometers, in which a least-squares support vector machine (LSSVM) is utilized. The compensation performance was analyzed by simulation, which shows that the LSSVM has better performance and less training time than backpropagation and radical basis function neural networks. The temperature characteristics of a DM fluxgate magnetometer were measured with a temperature experiment box. Forty-five measured data under different magnetic fields and temperatures were obtained and divided into 36 training data and nine test data. The training data were used to obtain the parameters of the LSSVM model, and the compensation performance of the LSSVM model was verified by the test data. Experimental results show that the temperature drift of magnetometer is reduced from 109.3 to 3.3 nT after compensation, which suggests that this compensation method is effective for the accuracy improvement of fluxgate magnetometers. (paper)

  18. Nonlinear temperature compensation of fluxgate magnetometers with a least-squares support vector machine

    Science.gov (United States)

    Pang, Hongfeng; Chen, Dixiang; Pan, Mengchun; Luo, Shitu; Zhang, Qi; Luo, Feilu

    2012-02-01

    Fluxgate magnetometers are widely used for magnetic field measurement. However, their accuracy is influenced by temperature. In this paper, a new method was proposed to compensate the temperature drift of fluxgate magnetometers, in which a least-squares support vector machine (LSSVM) is utilized. The compensation performance was analyzed by simulation, which shows that the LSSVM has better performance and less training time than backpropagation and radical basis function neural networks. The temperature characteristics of a DM fluxgate magnetometer were measured with a temperature experiment box. Forty-five measured data under different magnetic fields and temperatures were obtained and divided into 36 training data and nine test data. The training data were used to obtain the parameters of the LSSVM model, and the compensation performance of the LSSVM model was verified by the test data. Experimental results show that the temperature drift of magnetometer is reduced from 109.3 to 3.3 nT after compensation, which suggests that this compensation method is effective for the accuracy improvement of fluxgate magnetometers.

  19. Magnetometer Data recovered from 35mm film

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The L57 CDMP recovery project takes magnetometer data on 35mm film stored at the archive's climate controlled warehouse and digitizes them.

  20. A broadband two axis flux-gate magnetometer

    Directory of Open Access Journals (Sweden)

    P. Palangio

    1998-06-01

    Full Text Available A broadband two axis flux-gate magnetometer was developed to obtain high sensitivity in magnetotelluric measurements. In magnetotelluric sounding, natural low frequency electromagnetic fields are used to estimate the conductivity of the Earth's interior. Because variations in the natural magnetic field have small amplitude(10-100 pT in the frequency range 1 Hz to 100 Hz, highly sensitive magnetic sensors are required. In magnetotelluric measurements two long and heavy solenoids, which must be installed, in the field station, perpendicular to each other (north-south and east-west and levelled in the horizontal plane are used. The coil is a critical component in magnetotelluric measurements because very slight motions create noise voltages, particularly troublesome in wooded areas; generally the installation takes place in a shallow trench. Moreover the coil records the derivative of the variations rather than the magnetic field variations, consequently the transfer function (amplitude and phase of this sensor is not constant throughout the frequency range 0.001-100 Hz. The instrument, developed at L'Aquila Geomagnetic Observatory, has a flat response in both amplitude and phase in the frequency band DC-100 Hz, in addition it has low weight, low power, small volume and it is easier to install in the field than induction magnetometers. The sensivity of this magnetometer is 10 pT rms.

  1. Fluxgate Magnetometer Array for Geomagnetic Abnormal Phenomena Tracking

    Directory of Open Access Journals (Sweden)

    Xiaomei Wang

    2011-06-01

    Full Text Available The objective of this project is to develop a flexible observation mode for a geomagnetic abnormal phenomena tracking system. The instrument, based on ring core fluxgate magnetometer technology, improves the field environment performance. Using wireless technology provides on-the-spot mobile networking for the observational data, with efficient access to the earthquake precursor observation network. It provides a powerful detection method for earthquake short-term prediction through installation of a low-noise fluxgate magnetometer array, intensely observing the phenomenon of geomagnetic disturbances and abnormal low-frequency electromagnetic signals in different latitudes, then carrying out observational data processing and exploring the relationship between earthquake activity and geomagnetic field changes.

  2. Miniature scientific-grade induction magnetometer for cubesats

    Science.gov (United States)

    Pronenko, Vira

    2017-04-01

    One of the main areas of space research is the study and forecasting of space weather. The society is more and more depending nowadays on satellite technology and communications, so it is vital to understand the physical process in the solar-terrestrial system which may disturb them. Besides the solar radiation and Space Weather effects, the Earth's ionosphere is also modified by the ever increasing industrial activity. There have been also multiple reports relating VLF and ELF wave activity to atmospheric storms and geological processes, such as earthquakes and volcanic activity. For advancing in these fields, the AC magnetic field permanent monitoring is crucial. Using the cubesat technology would allow increasing the number of measuring points dramatically. It is necessary to mention that the cubesats use for scientific research requires the miniaturization of scientific sensors what is a serious problem because the reduction of their dimensions leads, as a rule, to the parameters degradation, especially of sensitivity threshold. Today, there is no basic model of a sensitive miniature induction magnetometer. Even the smallest one of the known - for the Bepi-Colombo mission to Mercury - is too big for cubesats. The goal of the present report is to introduce the new design of miniature three-component sensor for measurement of alternative vector magnetic fields - induction magnetometer (IM). The study directions were concentrated on the ways and possibilities to create the miniature magnetometer with best combination of parameters. For this a set of scientific and technological problems, mostly aimed at the sensor construction improvement, was solved. The most important parameter characterizing magnetometer quality is its own magnetic noise level (NL). The analysis of the NL influencing factors is made and the ways to decrease it are discussed in the report. Finally, the LEMI-151 IM was developed for the SEAM cubesat mission with optimal performances within the

  3. The Fluxgate Magnetometer Simulation in Comsol Multiphysics

    OpenAIRE

    Kolomeytsev Andrey; Baranov Pavel; Zatonov Ivan

    2018-01-01

    This article describes the fluxgate magnetometer simulation in Comsol Multiphysics software package. The simulation results coincide with the experiment described earlier. Decomposition of the output signal by the Fourier coefficients shows a frequency doubling.

  4. Swarm's absolute magnetometer experimental vector mode, an innovative capability for space magnetometry

    DEFF Research Database (Denmark)

    Hulot, Gauthier; Vigneron, Pierre; Leger, Jean-Michel

    2015-01-01

    , combining ASM scalar data with independent uxgate magnetometer vector data. The high level of agreement between these models demonstrates the potential of the ASM's vector mode for data quality control and as a stand alone magnetometer, and illustrates the way the evolution of key eld features can easily...

  5. The low cost Proton Precession Magnetometer developed at the Indian Institute of Geomagnetism

    International Nuclear Information System (INIS)

    Mahavarkar, P.; Singh, S.; Labde, S.; Dongre, V.; Patil, A.

    2017-01-01

    Proton magnetometers are the oldest scalar magnetometers. The first commercial units were produced in early 1960s as portable instruments. In continuation airborne instruments appeared with optimized speed of readings and sensitivity, large sensors etc. Later development of Overhauser and optically pumped magnetometers has eliminated Proton magnetometers from airborne surveys. However they remain very popular in various ground surveys and observatories. With this primary purpose of generating the ground based magnetic data, the Indian Institute of Geomagnetism (IIG) for the last 3 decades have been developing low cost Proton Precession Magnetometers (PPM). Beginning with the 1 nT PPM which has undergone several changes in design, the successor PM7 the advanced version has been successfully developed by the institute and is installed at various observatories of the institute. PM7 records the total field 'F' with accuracy of 0.1 nT and a sampling rate of 10 seconds/sample. This article briefly discusses the design and development of this IIG make PM7 and compares the data recorded by this instrument with one of the commercially available Overhauser magnetometer in the world market. The quality of data recorded by PM7 is in excellent agreement with the Overhauser. With the available quality of data generated by this instrument, PM7 is an affordable PPM for scientific institutions, schools and colleges intending to carry out geomagnetic studies. The commercial cost of PM7 is ≈ 20% of the cost of Overhauser available in market.

  6. The low cost Proton Precession Magnetometer developed at the Indian Institute of Geomagnetism

    Science.gov (United States)

    Mahavarkar, P.; Singh, S.; Labde, S.; Dongre, V.; Patil, A.

    2017-05-01

    Proton magnetometers are the oldest scalar magnetometers. The first commercial units were produced in early 1960s as portable instruments. In continuation airborne instruments appeared with optimized speed of readings and sensitivity, large sensors etc. Later development of Overhauser and optically pumped magnetometers has eliminated Proton magnetometers from airborne surveys. However they remain very popular in various ground surveys and observatories. With this primary purpose of generating the ground based magnetic data, the Indian Institute of Geomagnetism (IIG) for the last 3 decades have been developing low cost Proton Precession Magnetometers (PPM). Beginning with the 1 nT PPM which has undergone several changes in design, the successor PM7 the advanced version has been successfully developed by the institute and is installed at various observatories of the institute. PM7 records the total field `F' with accuracy of 0.1 nT and a sampling rate of 10 seconds/sample. This article briefly discusses the design and development of this IIG make PM7 and compares the data recorded by this instrument with one of the commercially available Overhauser magnetometer in the world market. The quality of data recorded by PM7 is in excellent agreement with the Overhauser. With the available quality of data generated by this instrument, PM7 is an affordable PPM for scientific institutions, schools and colleges intending to carry out geomagnetic studies. The commercial cost of PM7 is ≈ 20% of the cost of Overhauser available in market.

  7. Integrated de SQUID magnetometer with high dV/dB

    International Nuclear Information System (INIS)

    Drung, D.; Cantor, R.; Peters, M.; Ryhanen, T.; Kochi, H.

    1991-01-01

    This paper presents a directly coupled dc SQUID magnetometer with very simple feedback electronics. The magnetometer has been integrated on a 7.2 x 7.2 mm 2 chip and fabricated using a four-level Nb/Si x N v /Nb process. Eight pick-up loops are connected in parallel to directly form the SQUID inductance of about 0.4 nH which leads to a high sensitivity B/Φ = 0.47 nT/Φ. An Additional Positive Feedback (APF) circuit on the magnetometer chip has been used to increase the gradient of the V-μ characteristic to dV/dΦ ≅ 300 μV/Φ 0 at the SQUID operating point. The resulting gradient of the transfer function of dV/dB ≅ 640 μV/nT makes it possible to directly read out the SQUID without helium temperature impedance matching circuits or flux modulation techniques

  8. Swarm Optimization-Based Magnetometer Calibration for Personal Handheld Devices

    Directory of Open Access Journals (Sweden)

    Naser El-Sheimy

    2012-09-01

    Full Text Available Inertial Navigation Systems (INS consist of accelerometers, gyroscopes and a processor that generates position and orientation solutions by integrating the specific forces and rotation rates. In addition to the accelerometers and gyroscopes, magnetometers can be used to derive the user heading based on Earth’s magnetic field. Unfortunately, the measurements of the magnetic field obtained with low cost sensors are usually corrupted by several errors, including manufacturing defects and external electro-magnetic fields. Consequently, proper calibration of the magnetometer is required to achieve high accuracy heading measurements. In this paper, a Particle Swarm Optimization (PSO-based calibration algorithm is presented to estimate the values of the bias and scale factor of low cost magnetometers. The main advantage of this technique is the use of the artificial intelligence which does not need any error modeling or awareness of the nonlinearity. Furthermore, the proposed algorithm can help in the development of Pedestrian Navigation Devices (PNDs when combined with inertial sensors and GPS/Wi-Fi for indoor navigation and Location Based Services (LBS applications.

  9. A novel HTS magnetometer, exploiting the low jc of bulk YBCO

    International Nuclear Information System (INIS)

    Gallop, J.C.; Lilleyman, S.; Langham, C.D.; Radcliffe, W.J.; Stewart, M.

    1989-01-01

    The authors report here a novel of magnetometer which is based on the low critical magnetic field H/sub cl/ of sintered samples of the high temperature ceramic superconductor YBa/sub 2/Cu/sub 3/O/sub y/. By driving a sample of the superconductor around a magnetization hysteresis loop, at a frequency of --100 kHz, and detecting the induced voltage in a coil coupled to the sample, at the second harmonic of the drive frequency, the authors find that this voltage is linearly dependent on the aplied d.c. magnetic field in which the sample is situated. They present a model which explains the operation of this magnetometer. This device, while not as sensitive as a SQUID, has the advantage of a wider dynamic range and direct measurement of flux density, unlike a SQUID which is only capable of sensing flux density changes. When operated at 77K the prototype magnetometer has already demonstrated a sensitivity at least 10 times better than that of a commercial fluxgate magnetometer. The system also appears to provide a simple method for investigation of flux flow in these materials

  10. The IRM fluxgate magnetometer

    Science.gov (United States)

    Luehr, H.; Kloecker, N.; Oelschlaegel, W.; Haeusler, B.; Acuna, M.

    1985-01-01

    This report describes the three-axis fluxgate magnetometer instrument on board the AMPTE IRM spacecraft. Important features of the instrument are its wide dynamic range (0.1-60,000 nT), a high resolution (16-bit analog to digital conversion) and the capability to operate automatically or via telecommand in two gain states. In addition, the wave activity is monitored in all three components up to 50 Hz. Inflight checkout proved the nominal functioning of the instrument in all modes.

  11. The Fluxgate Magnetometer Simulation in Comsol Multiphysics

    Directory of Open Access Journals (Sweden)

    Kolomeytsev Andrey

    2018-01-01

    Full Text Available This article describes the fluxgate magnetometer simulation in Comsol Multiphysics software package. The simulation results coincide with the experiment described earlier. Decomposition of the output signal by the Fourier coefficients shows a frequency doubling.

  12. Closed-cycle gas flow system for cooling a HTc dc-SQUID magnetometer

    NARCIS (Netherlands)

    Bosch, van den P.J.; Holland, H.J.; Brake, ter H.J.M.; Rogalla, H.

    1994-01-01

    A closed-cycle gas flow system for cooling a high-crit. temp. d.c.-superconducting quantum interference device (SQUID) magnetometer by means of a cryocooler has been designed, constructed and tested. The magnetometer is aimed to measure heart signals with a sensitivity of 0.1 pT/Hz1/2. The required

  13. Electromagnetic induction imaging with a radio-frequency atomic magnetometer

    Energy Technology Data Exchange (ETDEWEB)

    Deans, Cameron; Marmugi, Luca, E-mail: l.marmugi@ucl.ac.uk; Hussain, Sarah; Renzoni, Ferruccio [Department of Physics and Astronomy, University College London, Gower Street, London WC1E 6BT (United Kingdom)

    2016-03-07

    We report on a compact, tunable, and scalable to large arrays imaging device, based on a radio-frequency optically pumped atomic magnetometer operating in magnetic induction tomography modality. Imaging of conductive objects is performed at room temperature, in an unshielded environment and without background subtraction. Conductivity maps of target objects exhibit not only excellent performance in terms of shape reconstruction but also demonstrate detection of sub-millimetric cracks and penetration of conductive barriers. The results presented here demonstrate the potential of a future generation of imaging instruments, which combine magnetic induction tomography and the unmatched performance of atomic magnetometers.

  14. Self-Calibrating Vector Helium Magnetometer (SVHM), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase I SBIR proposal describes proposed development of a conceptual design for a Self-Calibrating Vector Helium Magnetometer (SVHM) for design and fabrication...

  15. MOURA magnetometer for Mars MetNet Precursor Mission. Its potential for an in situ magnetic environment and surface characterization

    Energy Technology Data Exchange (ETDEWEB)

    Diaz Michelena, M.; Sanz, R.; Fernandez, A.B.; Manuel, V. de; Cerdan, M.F.; Apestigue, V.; Arruego, I.; Azcue, J.; Dominguez, J.A.; Gonzalez, M.; Guerrero, H.; Sabau, M.; Kilian, R.; Baeza, O.; Ros, F.; Vazquez, M.; Tordesillas, J.M.; Covisa, P.; Aguado, J.

    2016-07-01

    MOURA magnetometer and gradiometer is part of the scientific instrumentation for Mars MetNet Precursor mission. This work describes the objective of the investigation, summarizes the work done in the design and development of the sensor as well as its calibration, and shows the demonstration campaigns to show the potential of such instrument for planetary landers and rovers. (Author)

  16. Hall probe magnetometer for SSC magnet cables

    International Nuclear Information System (INIS)

    Cross, R.W.; Goldfarb, R.B.

    1991-01-01

    The authors of this paper constructed a Hall probe magnetometer to measure the magnetization hysteresis loops of Superconducting Super Collider magnet cables. The instrument uses two Hall-effect field sensors to measure the applied field H and the magnetic induction B. Magnetization M is calculated from the difference of the two quantities. The Hall probes are centered coaxially in the bore of a superconducting solenoid with the B probe against the sample's broad surface. An alternative probe arrangement, in which M is measured directly, aligns the sample probe parallel to the field. The authors measured M as a function of H and field cycle rate both with and without a dc transport current. Flux creep as a function of current was measured from the dependence of ac loss on the cycling rate and from the decay of magnetization with time. Transport currents up to 20% of the critical current have minimal effect on magnetization and flux creep

  17. In-Flight Calibration Processes for the MMS Fluxgate Magnetometers

    Science.gov (United States)

    Bromund, K. R.; Leinweber, H. K.; Plaschke, F.; Strangeway, R. J.; Magnes, W.; Fischer, D.; Nakamura, R.; Anderson, B. J.; Russell, C. T.; Baumjohann, W.; hide

    2015-01-01

    The calibration effort for the Magnetospheric Multiscale Mission (MMS) Analog Fluxgate (AFG) and DigitalFluxgate (DFG) magnetometers is a coordinated effort between three primary institutions: University of California, LosAngeles (UCLA); Space Research Institute, Graz, Austria (IWF); and Goddard Space Flight Center (GSFC). Since thesuccessful deployment of all 8 magnetometers on 17 March 2015, the effort to confirm and update the groundcalibrations has been underway during the MMS commissioning phase. The in-flight calibration processes evaluatetwelve parameters that determine the alignment, orthogonalization, offsets, and gains for all 8 magnetometers usingalgorithms originally developed by UCLA and the Technical University of Braunschweig and tailored to MMS by IWF,UCLA, and GSFC. We focus on the processes run at GSFC to determine the eight parameters associated with spin tonesand harmonics. We will also discuss the processing flow and interchange of parameters between GSFC, IWF, and UCLA.IWF determines the low range spin axis offsets using the Electron Drift Instrument (EDI). UCLA determines the absolutegains and sensor azimuth orientation using Earth field comparisons. We evaluate the performance achieved for MMS andgive examples of the quality of the resulting calibrations.

  18. Particle swarm optimization algorithm based low cost magnetometer calibration

    Science.gov (United States)

    Ali, A. S.; Siddharth, S., Syed, Z., El-Sheimy, N.

    2011-12-01

    Inertial Navigation Systems (INS) consist of accelerometers, gyroscopes and a microprocessor provide inertial digital data from which position and orientation is obtained by integrating the specific forces and rotation rates. In addition to the accelerometers and gyroscopes, magnetometers can be used to derive the absolute user heading based on Earth's magnetic field. Unfortunately, the measurements of the magnetic field obtained with low cost sensors are corrupted by several errors including manufacturing defects and external electro-magnetic fields. Consequently, proper calibration of the magnetometer is required to achieve high accuracy heading measurements. In this paper, a Particle Swarm Optimization (PSO) based calibration algorithm is presented to estimate the values of the bias and scale factor of low cost magnetometer. The main advantage of this technique is the use of the artificial intelligence which does not need any error modeling or awareness of the nonlinearity. The estimated bias and scale factor errors from the proposed algorithm improve the heading accuracy and the results are also statistically significant. Also, it can help in the development of the Pedestrian Navigation Devices (PNDs) when combined with the INS and GPS/Wi-Fi especially in the indoor environments

  19. In-Flight Calibration Processes for the MMS Fluxgate Magnetometers

    Science.gov (United States)

    Bromund, K. R.; Leinweber, H. K.; Plaschke, F.; Strangeway, R. J.; Magnes, W.; Fischer, D.; Nakamura, R.; Anderson, B. J.; Russell, C. T.; Baumjohann, W.; Chutter, M.; Torbert, R. B.; Le, G.; Slavin, J. A.; Kepko, L.

    2015-12-01

    The calibration effort for the Magnetospheric Multiscale Mission (MMS) Analog Fluxgate (AFG) and Digital Fluxgate (DFG) magnetometers is a coordinated effort between three primary institutions: University of California, Los Angeles (UCLA); Space Research Institute, Graz, Austria (IWF); and Goddard Space Flight Center (GSFC). Since the successful deployment of all 8 magnetometers on 17 March 2015, the effort to confirm and update the ground calibrations has been underway during the MMS commissioning phase. The in-flight calibration processes evaluate twelve parameters that determine the alignment, orthogonalization, offsets, and gains for all 8 magnetometers using algorithms originally developed by UCLA and the Technical University of Braunschweig and tailored to MMS by IWF, UCLA, and GSFC. We focus on the processes run at GSFC to determine the eight parameters associated with spin tones and harmonics. We will also discuss the processing flow and interchange of parameters between GSFC, IWF, and UCLA. IWF determines the low range spin axis offsets using the Electron Drift Instrument (EDI). UCLA determines the absolute gains and sensor azimuth orientation using Earth field comparisons. We evaluate the performance achieved for MMS and give examples of the quality of the resulting calibrations.

  20. The Pioneer 11 high-field fluxgate magnetometer

    Science.gov (United States)

    Acuna, M. H.; Ness, N. F.

    1973-01-01

    The High Field Fluxgate Magnetometer Experiment flow aboard the Pioneer 11 spacecraft to investigate Jupiter's magnetic field is described. The instrument extends the spacecraft's upper limit measurement capability by more than an order of magnitude to 17.3 gauss with minimum power and volume requirements.

  1. Development of Geomagnetic Monitoring System Using a Magnetometer for the Field

    Science.gov (United States)

    Lee, Young-Cheol; Kim, Sung-Wook; Choi, Eun-Kyeong; Kim, In-Soo

    2014-05-01

    Three institutes including KMA (Korea Meteorological Administration), KSWC (Korean Space Weather Center) of NRRA (National Radio Research Agency) and KIGAM (Korea Institute of Geoscience and Mineral Resources) are now operating magnetic observatories. Those observatories observe the total intensity and three components of geomagnetic element. This paper comes up with a magnetic monitoring system now under development that uses a magnetometer for field survey. In monitoring magnetic variations in areas (active faults or volcanic regions), more reliable results can be obtained when an array of several magnetometers are used rather than a single magnetometer. In order to establish and operate a magnetometer array, such factors as expenses, convenience of the establishment and operation of the array should be taken into account. This study has come up with a magnetic monitoring system complete with a magnetometer for the field survey of our own designing. A magnetic monitoring system, which is composed of two parts. The one is a field part and the other a data part. The field part is composed of a magnetometer, an external memory module, a power supply and a set of data transmission equipment. The data part is a data server which can store the data transmitted from the field part, analyze the data and provide service to the web. This study has developed an external memory module for ENVI-MAG (Scintrex Ltd.) using an embedded Cortex-M3 board, which can be programmed, attach other functional devices (SD memory cards, GPS antennas for time synchronization, ethernet cards and so forth). The board thus developed can store magnetic measurements up to 8 Gbytes, synchronize with the GPS time and transmit the magnetic measurements to the data server which is now under development. A monitoring system of our own developing was installed in Jeju island, taking measurements throughout Korea. Other parts including a data transfer module, a server and a power supply using solar

  2. Empirical Determination of Efficient Sensing Frequencies for Magnetometer-Based Continuous Human Contact Monitoring

    Directory of Open Access Journals (Sweden)

    Seungho Kuk

    2018-04-01

    Full Text Available The high linear correlation between the smartphone magnetometer readings in close proximity can be exploited for physical human contact detection, which could be useful for such applications as infectious disease contact tracing or social behavior monitoring. Alternative approaches using other capabilities in smartphones have aspects that do not fit well with the human contact detection. Using Wi-Fi or cellular fingerprints have larger localization errors than close human contact distances. Bluetooth beacons could reveal the identity of the transmitter, threatening the privacy of the user. Also, using sensors such as GPS does not work for indoor contacts. However, the magnetometer correlation check works best in human contact distances that matter in infectious disease transmissions or social interactions. The omni-present geomagnetism makes it work both indoors and outdoors, and the measured magnetometer values do not easily reveal the identity and the location of the smartphone. One issue with the magnetometer-based contact detection, however, is the energy consumption. Since the contacts can take place anytime, the magnetometer sensing and recording should be running continuously. Therefore, how we address the energy requirement for the extended and continuous operation can decide the viability of the whole idea. However, then, we note that almost all existing magnetometer-based applications such as indoor location and navigation have used high sensing frequencies, ranging from 10 Hz to 200 Hz. At these frequencies, we measure that the time to complete battery drain in a typical smartphone is shortened by three to twelve hours. The heavy toll raises the question as to whether the magnetometer-based contact detection can avoid such high sensing rates while not losing the contact detection accuracy. In order to answer the question, we conduct a measurement-based study using independently produced magnetometer traces from three different

  3. Empirical Determination of Efficient Sensing Frequencies for Magnetometer-Based Continuous Human Contact Monitoring.

    Science.gov (United States)

    Kuk, Seungho; Kim, Junha; Park, Yongtae; Kim, Hyogon

    2018-04-27

    The high linear correlation between the smartphone magnetometer readings in close proximity can be exploited for physical human contact detection, which could be useful for such applications as infectious disease contact tracing or social behavior monitoring. Alternative approaches using other capabilities in smartphones have aspects that do not fit well with the human contact detection. Using Wi-Fi or cellular fingerprints have larger localization errors than close human contact distances. Bluetooth beacons could reveal the identity of the transmitter, threatening the privacy of the user. Also, using sensors such as GPS does not work for indoor contacts. However, the magnetometer correlation check works best in human contact distances that matter in infectious disease transmissions or social interactions. The omni-present geomagnetism makes it work both indoors and outdoors, and the measured magnetometer values do not easily reveal the identity and the location of the smartphone. One issue with the magnetometer-based contact detection, however, is the energy consumption. Since the contacts can take place anytime, the magnetometer sensing and recording should be running continuously. Therefore, how we address the energy requirement for the extended and continuous operation can decide the viability of the whole idea. However, then, we note that almost all existing magnetometer-based applications such as indoor location and navigation have used high sensing frequencies, ranging from 10 Hz to 200 Hz. At these frequencies, we measure that the time to complete battery drain in a typical smartphone is shortened by three to twelve hours. The heavy toll raises the question as to whether the magnetometer-based contact detection can avoid such high sensing rates while not losing the contact detection accuracy. In order to answer the question, we conduct a measurement-based study using independently produced magnetometer traces from three different countries. Specifically, we

  4. GIOTTO MAGNETOMETER 8 SECOND DATA V1.0

    Data.gov (United States)

    National Aeronautics and Space Administration — The main objective of the Giotto Magnetometer Experiment is the investigation of the interaction between Comet Halley and the solar wind at a distance of 0.9 AU from...

  5. Machine Learning Based Localization and Classification with Atomic Magnetometers

    Science.gov (United States)

    Deans, Cameron; Griffin, Lewis D.; Marmugi, Luca; Renzoni, Ferruccio

    2018-01-01

    We demonstrate identification of position, material, orientation, and shape of objects imaged by a Rb 85 atomic magnetometer performing electromagnetic induction imaging supported by machine learning. Machine learning maximizes the information extracted from the images created by the magnetometer, demonstrating the use of hidden data. Localization 2.6 times better than the spatial resolution of the imaging system and successful classification up to 97% are obtained. This circumvents the need of solving the inverse problem and demonstrates the extension of machine learning to diffusive systems, such as low-frequency electrodynamics in media. Automated collection of task-relevant information from quantum-based electromagnetic imaging will have a relevant impact from biomedicine to security.

  6. Plasma Distribution in Mercury's Magnetosphere Derived from MESSENGER Magnetometer and Fast Imaging Plasma Spectrometer Observations

    Science.gov (United States)

    Korth, Haje; Anderson, Brian J.; Gershman, Daniel J.; Raines, Jim M.; Slavin, James A.; Zurbuchen, Thomas H.; Solomon, Sean C.; McNutt, Ralph L.

    2014-01-01

    We assess the statistical spatial distribution of plasma in Mercury's magnetosphere from observations of magnetic pressure deficits and plasma characteristics by the MErcury Surface, Space ENvironment, GEochemistry, and Ranging (MESSENGER) spacecraft. The statistical distributions of proton flux and pressure were derived from 10months of Fast Imaging Plasma Spectrometer (FIPS) observations obtained during the orbital phase of the MESSENGER mission. The Magnetometer-derived pressure distributions compare favorably with those deduced from the FIPS observations at locations where depressions in the magnetic field associated with the presence of enhanced plasma pressures are discernible in the Magnetometer data. The magnitudes of the magnetic pressure deficit and the plasma pressure agree on average, although the two measures of plasma pressure may deviate for individual events by as much as a factor of approximately 3. The FIPS distributions provide better statistics in regions where the plasma is more tenuous and reveal an enhanced plasma population near the magnetopause flanks resulting from direct entry of magnetosheath plasma into the low-latitude boundary layer of the magnetosphere. The plasma observations also exhibit a pronounced north-south asymmetry on the nightside, with markedly lower fluxes at low altitudes in the northern hemisphere than at higher altitudes in the south on the same field line. This asymmetry is consistent with particle loss to the southern hemisphere surface during bounce motion in Mercury's offset dipole magnetic field.

  7. Athermal fiber laser for the SWARM absolute scalar magnetometer

    Science.gov (United States)

    Fourcault, W.; Léger, J.-M.; Costes, V.; Fratter, I.; Mondin, L.

    2017-11-01

    The Absolute Scalar Magnetometer (ASM) developed by CEA-LETI/CNES is an optically pumped 4He magnetic field sensor based on the Zeeman effect and an electronic magnetic resonance whose effects are amplified by a laser pumping process [1-2]. Consequently, the role of the laser is to pump the 4He atoms at the D0 transition as well as to allow the magnetic resonance signal detection. The ASM will be the scalar magnetic reference instrument of the three ESA Swarm satellites to be launched in 2012 in order to carry out the best ever survey of the Earth magnetic field and its temporal evolution. The sensitivity and accuracy of this magnetometer based on 4He optical pumping depend directly on the characteristics of its light source, which is the key sub-system of the sensor. We describe in this paper the selected fiber laser architecture and its wavelength stabilization scheme. Its main performance in terms of spectral emission, optical power at 1083 nm and intensity noise characteristics in the frequency bands used for the operation of the magnetometer, are then presented. Environmental testing results (thermal vacuum cycling, vibrations, shocks and ageing) are also reported at the end of this paper.

  8. High Tc Josephson Junctions, SQUIDs and magnetometers

    International Nuclear Information System (INIS)

    Clarke, J.

    1991-01-01

    There has recently been considerable progress in the state-of-the-art of high-T c magnetometers based on dc SQUIDs (Superconducting Quantum Interference Devices). This progress is due partly to the development of more manufacturable Josephson junctions, making SQUIDs easier to fabricate, and partly to the development of multiturn flux transformers that convert the high sensitivity of SQUIDs to magnetic flux to a correspondingly high sensitivity to magnetic field. Needless to say, today's high-T c SQUIDs are still considerably less sensitive than their low-T c counterparts, particularly at low frequencies (f) where their level of 1/f noise remains high. Nonetheless, the performance of the high-T c devices has now reached the point where they are adequate for a number of the less demanding applications; furthermore, as we shall see, at least modest improvements in performance are expected in the near future. In this article, the author outlines these various developments. This is far from a comprehensive review of the field, however, and, apart from Sec. 2, he describes largely his own work. He begins in Sec. 2 with an overview of the various types of Josephson junctions that have been investigated, and in Sec. 3, he describes some of the SQUIDs that have been tested, and assess their performance. Section 4 discuss the development of the multilayer structures essential for an interconnect technology, and, in particular, for crossovers and vias. Section 5 shows how this technology enables one to fabricate multiturn flux transformers which, in turn, can be coupled to SQUIDs to make magnetometers. The performance and possible future improvements in these magnetometers are assessed, and some applications mentioned

  9. MgB2 magnetometer with a directly coupled pick-up loop

    Science.gov (United States)

    Portesi, C.; Mijatovic, D.; Veldhuis, D.; Brinkman, A.; Monticone, E.; Gonnelli, R. S.

    2006-05-01

    In this work, we show the results obtained in the fabrication and characterization of an MgB2 magnetometer with a directly coupled pick-up loop. We used an all in situ technique for fabricating magnesium diboride films, which consists of the co-evaporation of B and Mg by means of an e-gun and a resistive heater respectively. Consequently, we realized the superconducting device, which incorporates two nanobridges as weak links in a superconducting loop. The nanobridges were realized by focused ion beam milling; they were 240 nm wide and had a critical current density of 107 A cm-2. The magnetometer was characterized at different temperatures and also measurements of the noise levels have been performed. The device shows Josephson quantum interference up to 20 K and the calculated effective area at low temperatures was 0.24 mm2. The transport properties of the magnetometer allow determining fundamental materials properties of the MgB2 thin films, such as the penetration depth.

  10. Choice of optimal parameters for the superconductive quantum magnetometer

    Energy Technology Data Exchange (ETDEWEB)

    Vasiliev, B V; Ivanenko, A I; Trofimov, V N

    1974-12-31

    The problem of choosing the optimal coupling coefficient and optimal working frequency for superconductive quantum magnetometer is considered. The present experimental signalnoise dependence confirms the drawn conclusions. (auth)

  11. Mathematical model of a fluxgate magnetometer

    OpenAIRE

    Baranov Pavel F.; Baranova Vitalia E.; Nesterenko Tamara G.

    2018-01-01

    In paper analytical equations for calculate the electromotive force in the measuring coil of the fluxgate magnetometer independent of the drive signal frequency content are presented. Also, the equations for es-timation of the fluxgate sensitivity at any harmonic and for study fluxgates operation with a glance to the waveform and the polynomial approximation of the mean magnetization curve of the core are provided.

  12. Mathematical model of a fluxgate magnetometer

    Directory of Open Access Journals (Sweden)

    Baranov Pavel F.

    2018-01-01

    Full Text Available In paper analytical equations for calculate the electromotive force in the measuring coil of the fluxgate magnetometer independent of the drive signal frequency content are presented. Also, the equations for es-timation of the fluxgate sensitivity at any harmonic and for study fluxgates operation with a glance to the waveform and the polynomial approximation of the mean magnetization curve of the core are provided.

  13. Fluxgate magnetometers for outer planets exploration

    Science.gov (United States)

    Acuna, M. H.

    1974-01-01

    The exploration of the interplanetary medium and the magnetospheres of the outer planets requires the implementation of magnetic field measuring instrumentation with wide dynamic range, high stability, and reliability. The fluxgate magnetometers developed for the Pioneer 11 and Mariner-Jupiter-Saturn missions are presented. These instruments cover the range of .01 nT to 2 million nT with optimum performance characteristics and low power consumption.

  14. Digital Detection and feedback Fluxgate Magnetometer

    DEFF Research Database (Denmark)

    Piil-Henriksen, J.; Merayo, José M.G.; Nielsen, Otto V

    1996-01-01

    A new full Earth's field dynamic feedback fluxgate magnetometer is described. It is based entirely on digital signal processing and digital feedback control, thereby replacing the classical second harmonic tuned analogue electronics by processor algorithms. Discrete mathematical cross......-correlation routines and substantial oversampling reduce the noise to 71 pT root-mean-square in a 0.25-10 Hz bandwidth for a full Earth's field range instrument....

  15. Optimizations of spin-exchange relaxation-free magnetometer based on potassium and rubidium hybrid optical pumping

    International Nuclear Information System (INIS)

    Fang, Jiancheng; Wang, Tao; Li, Yang; Zhang, Hong; Zou, Sheng

    2014-01-01

    The hybrid optical pumping atomic magnetometers have not realized its theoretical sensitivity, the optimization is critical for optimal performance. The optimizations proposed in this paper are suitable for hybrid optical pumping atomic magnetometer, which contains two alkali species. To optimize the parameters, the dynamic equations of spin evolution with two alkali species were solved, whose steady-state solution is used to optimize the parameters. The demand of the power of the pump beam is large for hybrid optical pumping. Moreover, the sensitivity of the hybrid optical pumping magnetometer increases with the increase of the power density of the pump beam. The density ratio between the two alkali species is especially important for hybrid optical pumping magnetometer. A simple expression for optimizing the density ratio is proposed in this paper, which can help to determine the mole faction of the alkali atoms in fabricating the hybrid cell before the cell is sealed. The spin-exchange rate between the two alkali species is proportional to the saturated density of the alkali vapor, which is highly dependent on the temperature of the cell. Consequently, the sensitivity of the hybrid optical pumping magnetometer is dependent on the temperature of the cell. We proposed the thermal optimization of the hybrid cell for a hybrid optical pumping magnetometer, which can improve the sensitivity especially when the power of the pump beam is low. With these optimizations, a sensitivity of approximately 5 fT/Hz 1/2 is achieved with gradiometer arrangement

  16. Development of Magnetometer Digital Circuit for KSR-3 Rocket and Analytical Study on Calibration Result

    Directory of Open Access Journals (Sweden)

    Eun-Seok Lee

    2002-12-01

    Full Text Available This paper describes the re-design and the calibration results of the MAG digital circuit onboard the KSR-3. We enhanced the sampling rate of magnetometer data. Also, we reduced noise and increased authoritativeness of data. We could confirm that AIM resolution was decreased less than 1nT of analog calibration by a digital calibration of magnetometer. Therefore, we used numerical-program to correct this problem. As a result, we could calculate correction and error of data. These corrections will be applied to magnetometer data after the launch of KSR-3.

  17. Attitude-independent magnetometer calibration for marine magnetic surveys: regularization issue

    International Nuclear Information System (INIS)

    Wu, Zhitian; Hu, Xiaoping; Wu, Meiping; Cao, Juliang

    2013-01-01

    We have developed an attitude-independent calibration method for a shipboard magnetometer to estimate the absolute strength of the geomagnetic field from a marine vessel. The three-axis magnetometer to be calibrated is fixed on a rigid aluminium boom ahead of the vessel to reduce the magnetic effect of the vessel. Due to the constrained manoeuvres of the vessel, a linear observational equation system for calibration parameter estimation is severely ill-posed. Consequently, if the issue is not mitigated, traditional calibration methods may result in unreliable or unsuccessful solutions. In this paper, the ill-posed problem is solved by using the truncated total least squares (TTLS) technique. This method takes advantage of simultaneously considering errors on both sides of the observation equation. Furthermore, the TTLS method suits strongly ill-posed problems. Simulations and experiments have been performed to assess the performance of the TTLS method and to compare it with the performance of conventional regularization approaches such as the Tikhonov method and truncated single value decomposition. The results show that the proposed algorithm can effectively mitigate the ill-posed problem and is more stable than the compared regularization methods for magnetometer calibration applications. (paper)

  18. Feasibility Study for an Autonomous UAV -Magnetometer System -- Final Report on SERDP SEED 1509:2206

    Energy Technology Data Exchange (ETDEWEB)

    Roelof Versteeg; Mark McKay; Matt Anderson; Ross Johnson; Bob Selfridge; Jay Bennett

    2007-09-01

    Large areas across the United States are potentially contaminated with UXO, with some ranges encompassing tens to hundreds of thousands of acres. Technologies are needed which will allow for cost effective wide area scanning with 1) near 100 % coverage and 2) near 100 % detection of subsurface ordnance or features indicative of subsurface ordnance. The current approach to wide area scanning is a multi-level one, in which medium altitude fixed wing optical imaging is used for an initial site assessment. This assessment is followed with low altitude manned helicopter based magnetometry followed by surface investigations using either towed geophysical sensor arrays or man portable sensors. In order to be effective for small UXO detection, the sensing altitude for magnetic site investigations needs to be on the order of 1 – 3 meters. These altitude requirements means that manned helicopter surveys will generally only be feasible in large, open and relatively flat terrains. While such surveys are effective in mapping large areas relatively fast there are substantial mobilization/demobilization, staffing and equipment costs associated with these surveys (resulting in costs of approximately $100-$150/acre). Surface towed arrays provide high resolution maps but have other limitations, e.g. in their ability to navigate rough terrain effectively. Thus, other systems are needed allowing for effective data collection. An UAV (Unmanned Aerial Vehicle) magnetometer platform is an obvious alternative. The motivation behind such a system is that it would be safer for the operators, cheaper in initial and O&M costs, and more effective in terms of site characterization. However, while UAV data acquisition from fixed wing platforms for large (> 200 feet) stand off distances is relatively straight forward, a host of challenges exist for low stand-off distance (~ 6 feet) UAV geophysical data acquisition. The objective of SERDP SEED 1509:2006 was to identify the primary challenges

  19. Note: Commercial SQUID magnetometer-compatible NMR probe and its application for studying a quantum magnet.

    Science.gov (United States)

    Vennemann, T; Jeong, M; Yoon, D; Magrez, A; Berger, H; Yang, L; Živković, I; Babkevich, P; Rønnow, H M

    2018-04-01

    We present a compact nuclear magnetic resonance (NMR) probe which is compatible with a magnet of a commercial superconducting quantum interference device magnetometer and demonstrate its application to the study of a quantum magnet. We employ trimmer chip capacitors to construct an NMR tank circuit for low temperature measurements. Using a magnetic insulator MoOPO 4 with S = 1/2 (Mo 5+ ) as an example, we show that the T-dependence of the circuit is weak enough to allow the ligand-ion NMR study of magnetic systems. Our 31 P NMR results are compatible with previous bulk susceptibility and neutron scattering experiments and furthermore reveal unconventional spin dynamics.

  20. Note: Commercial SQUID magnetometer-compatible NMR probe and its application for studying a quantum magnet

    Science.gov (United States)

    Vennemann, T.; Jeong, M.; Yoon, D.; Magrez, A.; Berger, H.; Yang, L.; Živković, I.; Babkevich, P.; Rønnow, H. M.

    2018-04-01

    We present a compact nuclear magnetic resonance (NMR) probe which is compatible with a magnet of a commercial superconducting quantum interference device magnetometer and demonstrate its application to the study of a quantum magnet. We employ trimmer chip capacitors to construct an NMR tank circuit for low temperature measurements. Using a magnetic insulator MoOPO4 with S = 1/2 (Mo5+) as an example, we show that the T-dependence of the circuit is weak enough to allow the ligand-ion NMR study of magnetic systems. Our 31P NMR results are compatible with previous bulk susceptibility and neutron scattering experiments and furthermore reveal unconventional spin dynamics.

  1. Integrated high-transition temperature magnetometer with only two superconducting layers

    DEFF Research Database (Denmark)

    Kromann, R.; Kingston, J.J.; Miklich, A.H.

    1993-01-01

    We describe the fabrication and testing of an integrated YBa2Cu3O7-x thin-film magnetometer consisting of a dc superconducting quantum interference device (SQUID), with biepitaxial grain boundary junctions, integrated with a flux transformer on a single substrate. Only two superconducting layers...... are required, the SQUID body serving as the crossunder that completes the multiturn flux transformer. The highest temperature at which any of the magnetometers functioned was 76 K. At 60 K the magnetic field gain of this device was 63, and the magnetic field noise was 160 fT Hz-1/2 at 2 kHz, increasing to 3...

  2. The simple procedure for the fluxgate magnetometers calibration

    Science.gov (United States)

    Marusenkov, Andriy

    2014-05-01

    The fluxgate magnetometers are widely used in geophysics investigations including the geomagnetic field monitoring at the global network of geomagnetic observatories as well as for electromagnetic sounding of the Earth's crust conductivity. For solving these tasks the magnetometers have to be calibrated with an appropriate level of accuracy. As a particular case, the ways to satisfy the recent requirements to the scaling and orientation errors of 1-second INTERNAGNET magnetometers are considered in the work. The goal of the present study was to choose a simple and reliable calibration method for estimation of scale factors and angular errors of the three-axis magnetometers in the field. There are a large number of the scalar calibration methods, which use a free rotation of the sensor in the calibration field followed by complicated data processing procedures for numerical solution of the high-order equations set. The chosen approach also exploits the Earth's magnetic field as a calibrating signal, but, in contrast to other methods, the sensor has to be oriented in some particular positions in respect to the total field vector, instead of the sensor free rotation. This allows to use very simple and straightforward linear computation formulas and, as a result, to achieve more reliable estimations of the calibrated parameters. The estimation of the scale factors is performed by the sequential aligning of each component of the sensor in two positions: parallel and anti-parallel to the Earth's magnetic field vector. The estimation of non-orthogonality angles between each pair of components is performed after sequential aligning of the components at the angles +/- 45 and +/- 135 degrees of arc in respect to the total field vector. Due to such four positions approach the estimations of the non-orthogonality angles are invariant to the zero offsets and non-linearity of transfer functions of the components. The experimental justifying of the proposed method by means of the

  3. Validation of the GOES-16 magnetometer using multipoint measurements and magnetic field models

    Science.gov (United States)

    Califf, S.; Loto'aniu, P. T. M.; Redmon, R. J.; Sarris, T. E.; Brito, T.

    2017-12-01

    The Geostationary Operational Environmental Satellites (GOES) have been providing continuous geomagnetic field measurements for over 40 years. While the primary purpose of GOES is operational, the magnetometer data are also widely used in the scientific community. In an effort to validate the recently launched GOES-16 magnetometer, we compare the measurements to existing magnetic field models and other GOES spacecraft currently on orbit. There are four concurrent measurements from GOES-13, 14, 15 and 16 spanning 75W to 135W longitude. Also, GOES-13 is being replaced by GOES-16 in the GOES-East location, and during the transition, GOES-13 and GOES-16 will be parked nearby in order to assist with calibration of the new operational satellite. This work explores techniques to quantify the performance of the GOES-16 magnetometer by comparison to data from nearby spacecraft. We also build on previous work to assimilate in situ measurements with existing magnetic field models to assist in comparing data from different spatial locations. Finally, we use this unique dataset from four simultaneous geosynchronous magnetometer measurements and the close separation between GOES-13 and GOES-16 to study the spatial characteristics of ULF waves and other magnetospheric processes.

  4. Automated system for the calibration of magnetometers

    International Nuclear Information System (INIS)

    Petrucha, Vojtech; Kaspar, Petr; Ripka, Pavel; Merayo, Jose M. G.

    2009-01-01

    A completely nonmagnetic calibration platform has been developed and constructed at DTU Space (Technical University of Denmark). It is intended for on-site scalar calibration of high-precise fluxgate magnetometers. An enhanced version of the same platform is being built at the Czech Technical University. There are three axes of rotation in this design (compared to two axes in the previous version). The addition of the third axis allows us to calibrate more complex devices. An electronic compass based on a vector fluxgate magnetometer and micro electro mechanical systems (MEMS) accelerometer is one example. The new platform can also be used to evaluate the parameters of the compass in all possible variations in azimuth, pitch, and roll. The system is based on piezoelectric motors, which are placed on a platform made of aluminum, brass, plastic, and glass. Position sensing is accomplished through custom-made optical incremental sensors. The system is controlled by a microcontroller, which executes commands from a computer. The properties of the system as well as calibration and measurement results will be presented

  5. Detection Range of Airborne Magnetometers in Magnetic Anomaly Detection

    Directory of Open Access Journals (Sweden)

    Chengjing Li

    2015-11-01

    Full Text Available Airborne magnetometers are utilized for the small-range search, precise positioning, and identification of the ferromagnetic properties of underwater targets. As an important performance parameter of sensors, the detection range of airborne magnetometers is commonly set as a fixed value in references regardless of the influences of environment noise, target magnetic properties, and platform features in a classical model to detect airborne magnetic anomalies. As a consequence, deviation in detection ability analysis is observed. In this study, a novel detection range model is proposed on the basis of classic detection range models of airborne magnetometers. In this model, probability distribution is applied, and the magnetic properties of targets and the environment noise properties of a moving submarine are considered. The detection range model is also constructed by considering the distribution of the moving submarine during detection. A cell-averaging greatest-of-constant false alarm rate test method is also used to calculate the detection range of the model at a desired false alarm rate. The detection range model is then used to establish typical submarine search probabilistic models. Results show that the model can be used to evaluate not only the effects of ambient magnetic noise but also the moving and geomagnetic features of the target and airborne detection platform. The model can also be utilized to display the actual operating range of sensor systems.

  6. The Future of Ground Magnetometer Arrays in Support of Space Weather Monitoring and Research

    Science.gov (United States)

    Engebretson, Mark; Zesta, Eftyhia

    2017-11-01

    A community workshop was held in Greenbelt, Maryland, on 5-6 May 2016 to discuss recommendations for the future of ground magnetometer array research in space physics. The community reviewed findings contained in the 2016 Geospace Portfolio Review of the Geospace Section of the Division of Atmospheric and Geospace Science of the National Science Foundation and discussed the present state of ground magnetometer arrays and possible pathways for a more optimal, robust, and effective organization and scientific use of these ground arrays. This paper summarizes the report of that workshop to the National Science Foundation (Engebretson & Zesta, as well as conclusions from two follow-up meetings. It describes the current state of U.S.-funded ground magnetometer arrays and summarizes community recommendations for changes in both organizational and funding structures. It also outlines a variety of new and/or augmented regional and global data products and visualizations that can be facilitated by increased collaboration among arrays. Such products will enhance the value of ground-based magnetometer data to the community's effort for understanding of Earth's space environment and space weather effects.

  7. Mid-latitude Geomagnetic Field Analysis Using BOH Magnetometer: Preliminary Results

    Directory of Open Access Journals (Sweden)

    Junga Hwang

    2011-09-01

    Full Text Available Korea Astronomy and Space Science Institute researchers have installed and operated magnetometers at Mt. Bohyun Observatory to measure the Earth's magnetic field variations in South Korea. We, in 2007, installed a fluxgate magnetometer (RFP-523C to measure H, D, and Z components of the geomagnetic field. In addition, in 2009, we installed a Overhauser proton sensor to measure the absolute total magnetic field F and a three-axis magneto-impedance sensor for spectrum analysis. Currently three types of magnetometer data have been accumulated. In this paper, we provide the preliminary and the first statistical analysis using the BOH magnetometer installed at Mt. Bohyun Observatory. By superposed analysis, we find that daily variations of H, D, and Z shows similar tendency, that is, about 30 minutes before the meridian (11:28 a minimum appears and the time after about 3 hours and 30 minutes (15:28 a maximum appears. Also, a quiet interval start time (19:06 is near the sunset time, and a quiet interval end time (06:40 is near the sunrise time. From the sunset to the sunrise, the value of H has a nearly constant interval, that is, the sun affects the changes in H values. Seasonal variations show similar dependences to the sun. Local time variations show that noon region has the biggest variations and midnight region has the smallest variations. We compare the correlations between geomagnetic variations and activity indices as we expect the geomagnetic variation would contain the effects of geomagnetic activity variations. As a result, the correlation coefficient between H and Dst is the highest (r = 0.947, and other AL, AE, AU index and showed a high correlation. Therefore, the effects of geomagnetic storms and geomagnetic substorms might contribute to the geomagnetic changes significantly.

  8. Z3 model of Saturns magnetic field and the Pioneer 11 vector helium magnetometer observations

    International Nuclear Information System (INIS)

    Connerney, J.E.P.; Acuna, M.H.; Ness, N.F.

    1984-05-01

    Magnetic field observations obtained by the Pioneer 11 vector helium magnetometer are compared with the Z(sub 3) model magnetic field. These Pioneer 11 observations, obtained at close-in radial distances, constitute an important and independent test of the Z(sub 3) zonal harmonic model, which was derived from Voyager 1 and Voyager 2 fluxgate magnetometer observations. Differences between the Pioneer 11 magnetometer and the Z(sub 3) model field are found to be small (approximately 1%) and quantitatively consistent with the expected instrumental accuracy. A detailed examination of these differences in spacecraft payload coordinates shows that they are uniquely associated with the instrument frame of reference and operation. A much improved fit to the Pioneer 11 observations is obtained by rotation of the instrument coordinate system about the spacecraft spin axis by 1.4 degree. With this adjustment, possibly associated with an instrumental phase lag or roll attitude error, the Pioneer 11 vector helium magnetometer observations are fully consistent with the Voyager Z(sub 3) model

  9. High temperature superconductive flux gate magnetometer

    International Nuclear Information System (INIS)

    Gershenson, M.

    1991-01-01

    This paper proposes a different type of HTS superconducting magnetometer based on the non-linear magnetic behavior of bulk HTS materials. The device design is based on the generation of second harmonics which arise as a result of non-linear magnetization observed in Type-II superconductors. Even harmonics are generated from the non-linear interaction of an ac excitation signal with an external DC magnetic field which acts as a bias signal

  10. Automatic torque magnetometer for vacuum-to-high-pressure hydrogen environments

    International Nuclear Information System (INIS)

    Larsen, J.W.; Livesay, B.R.

    1979-01-01

    An automatic torque magnetometer has been developed for use in high-pressure hydrogen. It will contain pressures ranging from vacuum to 200 atm of hydrogen gas at sample temperatures greater than 400 0 C. This magnetometer, which uses an optical lever postion sensor and a restoring force technique has an operating range of 2.0 x 10 3 dyn cm to l.6 x 10 -4 dyn cm. An accompanying digital data collection system extends the sensitivity to 1 x 10 -5 dyn cm as well as increasing the data handling capacity of the system. The magnetic properties of thin films in high-temperature and high-pressure hydrogen environments can be studied using this instruments

  11. VOYAGER 1 SATURN MAGNETOMETER RESAMPLED DATA 9.60 SEC

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set includes Voyager 1 Saturn encounter magnetometer data that have been resampled at a 9.6 second sample rate. The data set is composed of 6 columns: 1)...

  12. VOYAGER 2 JUPITER MAGNETOMETER RESAMPLED DATA 48.0 SEC

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set includes Voyager 2 Jupiter encounter magnetometer data that have been resampled at a 48.0 second sample rate. The data set is composed of 6 columns: 1)...

  13. The absolute magnetometers on board Swarm, lessons learned from more than two years in space

    DEFF Research Database (Denmark)

    Hulot, Gauthier; Leger, Jean-Michel; Vigneron, Pierre

    ESA's Swarm satellites carry 4He absolute magnetometers (ASM), designed by CEA-Léti and developed in partnership with CNES. These instruments are the first-ever space-borne magnetometers to use a common sensor to simultaneously deliver 1Hz independent absolute scalar and vector readings of the ma...

  14. Performance Improvement of Inertial Navigation System by Using Magnetometer with Vehicle Dynamic Constraints

    Directory of Open Access Journals (Sweden)

    Daehee Won

    2015-01-01

    Full Text Available A navigation algorithm is proposed to increase the inertial navigation performance of a ground vehicle using magnetic measurements and dynamic constraints. The navigation solutions are estimated based on inertial measurements such as acceleration and angular velocity measurements. To improve the inertial navigation performance, a three-axis magnetometer is used to provide the heading angle, and nonholonomic constraints (NHCs are introduced to increase the correlation between the velocity and the attitude equation. The NHCs provide a velocity feedback to the attitude, which makes the navigation solution more robust. Additionally, an acceleration-based roll and pitch estimation is applied to decrease the drift when the acceleration is within certain boundaries. The magnetometer and NHCs are combined with an extended Kalman filter. An experimental test was conducted to verify the proposed method, and a comprehensive analysis of the performance in terms of the position, velocity, and attitude showed that the navigation performance could be improved by using the magnetometer and NHCs. Moreover, the proposed method could improve the estimation performance for the position, velocity, and attitude without any additional hardware except an inertial sensor and magnetometer. Therefore, this method would be effective for ground vehicles, indoor navigation, mobile robots, vehicle navigation in urban canyons, or navigation in any global navigation satellite system-denied environment.

  15. Construction and calibration of a low cost and fully automated vibrating sample magnetometer

    International Nuclear Information System (INIS)

    El-Alaily, T.M.; El-Nimr, M.K.; Saafan, S.A.; Kamel, M.M.; Meaz, T.M.; Assar, S.T.

    2015-01-01

    A low cost vibrating sample magnetometer (VSM) has been constructed by using an electromagnet and an audio loud speaker; where both are controlled by a data acquisition device. The constructed VSM records the magnetic hysteresis loop up to 8.3 KG at room temperature. The apparatus has been calibrated and tested by using magnetic hysteresis data of some ferrite samples measured by two scientifically calibrated magnetometers; model (Lake Shore 7410) and model (LDJ Electronics Inc. Troy, MI). Our VSM lab-built new design proved success and reliability. - Highlights: • A low cost automated vibrating sample magnetometer VSM has been constructed. • The VSM records the magnetic hysteresis loop up to 8.3 KG at room temperature. • The VSM has been calibrated and tested by using some measured ferrite samples. • Our VSM lab-built new design proved success and reliability

  16. Construction and calibration of a low cost and fully automated vibrating sample magnetometer

    Energy Technology Data Exchange (ETDEWEB)

    El-Alaily, T.M., E-mail: toson_alaily@yahoo.com [Physics Department, Faculty of Science, Tanta University, Tanta (Egypt); El-Nimr, M.K.; Saafan, S.A.; Kamel, M.M.; Meaz, T.M. [Physics Department, Faculty of Science, Tanta University, Tanta (Egypt); Assar, S.T. [Engineering Physics and Mathematics Department, Faculty of Engineering, Tanta University, Tanta (Egypt)

    2015-07-15

    A low cost vibrating sample magnetometer (VSM) has been constructed by using an electromagnet and an audio loud speaker; where both are controlled by a data acquisition device. The constructed VSM records the magnetic hysteresis loop up to 8.3 KG at room temperature. The apparatus has been calibrated and tested by using magnetic hysteresis data of some ferrite samples measured by two scientifically calibrated magnetometers; model (Lake Shore 7410) and model (LDJ Electronics Inc. Troy, MI). Our VSM lab-built new design proved success and reliability. - Highlights: • A low cost automated vibrating sample magnetometer VSM has been constructed. • The VSM records the magnetic hysteresis loop up to 8.3 KG at room temperature. • The VSM has been calibrated and tested by using some measured ferrite samples. • Our VSM lab-built new design proved success and reliability.

  17. Adaption of the Magnetometer Towed Array geophysical system to meet Department of Energy needs for hazardous waste site characterization

    International Nuclear Information System (INIS)

    Cochran, J.R.; McDonald, J.R.; Russell, R.J.; Robertson, R.; Hensel, E.

    1995-10-01

    This report documents US Department of Energy (DOE)-funded activities that have adapted the US Navy's Surface Towed Ordnance Locator System (STOLS) to meet DOE needs for a ''... better, faster, safer and cheaper ...'' system for characterizing inactive hazardous waste sites. These activities were undertaken by Sandia National Laboratories (Sandia), the Naval Research Laboratory, Geo-Centers Inc., New Mexico State University and others under the title of the Magnetometer Towed Array (MTA)

  18. Simplified High-Performance Roll Out Composite Magnetometer Boom, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — In response to NASA's need for compact, low-cost deployable magnetometer booms for CubeSats, Roccor proposes to develop a Simple High-performance Roll-Out Composite...

  19. MgB{sub 2} magnetometer with a directly coupled pick-up loop

    Energy Technology Data Exchange (ETDEWEB)

    Portesi, C [Istituto Elettrotecnico Nazionale Galileo Ferraris, Strada delle Cacce 91, I-10135 Turin (Italy); Mijatovic, D [Low Temperature Division and Mesa Research Institute, University of Twente, PO Box 217, 7500 AE Enschede (Netherlands); Veldhuis, D [Low Temperature Division and Mesa Research Institute, University of Twente, PO Box 217, 7500 AE Enschede (Netherlands); Brinkman, A [Low Temperature Division and Mesa Research Institute, University of Twente, PO Box 217, 7500 AE Enschede (Netherlands); Monticone, E [Istituto Elettrotecnico Nazionale Galileo Ferraris, Strada delle Cacce 91, I-10135 Turin (Italy); Gonnelli, R S [INFM, Dipartimento di Fisica, Politecnico di Torino, Corso Duca degli Abruzzi 24, I-10129 Turin (Italy)

    2006-05-15

    In this work, we show the results obtained in the fabrication and characterization of an MgB{sub 2} magnetometer with a directly coupled pick-up loop. We used an all in situ technique for fabricating magnesium diboride films, which consists of the co-evaporation of B and Mg by means of an e-gun and a resistive heater respectively. Consequently, we realized the superconducting device, which incorporates two nanobridges as weak links in a superconducting loop. The nanobridges were realized by focused ion beam milling; they were 240 nm wide and had a critical current density of 10{sup 7} A cm{sup -2}. The magnetometer was characterized at different temperatures and also measurements of the noise levels have been performed. The device shows Josephson quantum interference up to 20 K and the calculated effective area at low temperatures was 0.24 mm{sup 2}. The transport properties of the magnetometer allow determining fundamental materials properties of the MgB{sub 2} thin films, such as the penetration depth.

  20. Intense auroral field-aligned currents and electrojets detected by rocket-borne fluxgate magnetometer

    International Nuclear Information System (INIS)

    Tohyama, Fumio; Fukunishi, Hiroshi; Takahashi, Takao; Kokubun, Susumu; Fujii, Ryoichi; Yamagishi, Hisao.

    1988-01-01

    The S-310JA-11 and S-310JA-12 rockets, having a vector magnetometer with high sensitivity (1.8 nT) and high sampling frequency (100 Hz), were launched into the aurora on May 29 and July 12, 1985, from Syowa Station, Antarctica. The S-310JA-11 rocket penetrated twice quiet arcs, while the S-310JA-12 rocket traversed across intense and active auroral arcs during a large magnetic substorm. In the S-310JA-12 rocket experiment, intense field-aligned currents of 400 - 600 nT were observed when the rocket penetrated an active arc during the descending flight. The magnetometer on board the S-310JA-12 rocket also detected intense electrojet currents with a center at 110 km on the upward leg and at 108 km on the downward leg. The magnetometer data of the S-310JA-11 rocket showed no distinguished magnetic field variation due to field-aligned current and electrojet. (author)

  1. Characterization and demonstration results of a SQUID magnetometer system developed for geomagnetic field measurements

    Science.gov (United States)

    Kawai, J.; Miyamoto, M.; Kawabata, M.; Nosé, M.; Haruta, Y.; Uehara, G.

    2017-08-01

    We characterized a low temperature superconducting quantum interference device (SQUID) magnetometer system developed for high-sensitivity geomagnetic field measurement, and demonstrated the detection of weak geomagnetic signals. The SQUID magnetometer system is comprised of three-axis SQUID magnetometers housed in a glass fiber reinforced plastic cryostat, readout electronics with flux locked loop (FLL), a 24-bit data logger with a global positioning system and batteries. The system noise was approximately 0.2 pT √Hz- 1/2 in the 1-50 Hz frequency range. This performance was determined by including the thermal noise and the shielding effect of the copper shield, which covered the SQUID magnetometers to eliminate high-frequency interference. The temperature drift of the system was ˜0.8 pT °C- 1 in an FLL operation. The system operated for a month using 33 l liquid helium. Using this system, we performed the measurements of geomagnetic field in the open-air, far away from the city. The system could detect weak geomagnetic signals such as the Schumann resonance with sixth harmonics, and the ionospheric Alfvén resonance appearing at night, for the north-south and east-west components of the geomagnetic field. We confirm that the system was capable of high-sensitivity measurement of the weak geomagnetic activities.

  2. Probabilistic resident space object detection using archival THEMIS fluxgate magnetometer data

    Science.gov (United States)

    Brew, Julian; Holzinger, Marcus J.

    2018-05-01

    Recent progress in the detection of small space objects, at geosynchronous altitudes, through ground-based optical and radar measurements is demonstrated as a viable method. However, in general, these methods are limited to detection of objects greater than 10 cm. This paper examines the use of magnetometers to detect plausible flyby encounters with charged space objects using a matched filter signal existence binary hypothesis test approach. Relevant data-set processing and reduction of archival fluxgate magnetometer data from the NASA THEMIS mission is discussed in detail. Using the proposed methodology and a false alarm rate of 10%, 285 plausible detections with probability of detection greater than 80% are claimed and several are reviewed in detail.

  3. Measuring In-Flight Angular Motion With a Low-Cost Magnetometer

    National Research Council Canada - National Science Library

    Harkins, Thomas E; Wilson, Michael J

    2007-01-01

    A technique for obtaining pitch, yaw, and roll rates of a projectile from a single, low-cost, commercial off-the-shelf magnetometer has been developed at the Advanced Munitions Concepts Branch of the U.S...

  4. Construction and calibration of a low cost and fully automated vibrating sample magnetometer

    Science.gov (United States)

    El-Alaily, T. M.; El-Nimr, M. K.; Saafan, S. A.; Kamel, M. M.; Meaz, T. M.; Assar, S. T.

    2015-07-01

    A low cost vibrating sample magnetometer (VSM) has been constructed by using an electromagnet and an audio loud speaker; where both are controlled by a data acquisition device. The constructed VSM records the magnetic hysteresis loop up to 8.3 KG at room temperature. The apparatus has been calibrated and tested by using magnetic hysteresis data of some ferrite samples measured by two scientifically calibrated magnetometers; model (Lake Shore 7410) and model (LDJ Electronics Inc. Troy, MI). Our VSM lab-built new design proved success and reliability.

  5. Membrane-based torque magnetometer: Enhanced sensitivity by optical readout of the membrane displacement

    Science.gov (United States)

    Blankenhorn, M.; Heintze, E.; Slota, M.; van Slageren, J.; Moores, B. A.; Degen, C. L.; Bogani, L.; Dressel, M.

    2017-09-01

    The design and realization of a torque magnetometer is reported that reads the deflection of a membrane by optical interferometry. The compact instrument allows for low-temperature measurements of tiny crystals less than a microgram with a significant improvement in sensitivity, signal-to-noise ratio as well as data acquisition time compared with conventional magnetometry and offers an enormous potential for further improvements and future applications in different fields. Magnetic measurements on single-molecule magnets demonstrate the applicability of the membrane-based torque magnetometer.

  6. Digital Fluxgate Magnetometer for Detection of Microvibration

    Directory of Open Access Journals (Sweden)

    Menghui Zhi

    2017-01-01

    Full Text Available In engineering practice, instruments, such as accelerometer and laser interferometer, are widely used in vibration measurement of structural parts. A method for using a triaxial fluxgate magnetometer as a microvibration sensor to measure low-frequency pendulum microvibration (not translational vibration is proposed in this paper, so as to detect vibration from low-frequency vibration sources, such as large rotating machine, large engineering structure, earthquake, and microtremor. This method provides vibration detection based on the environmental magnetic field signal to avoid increased measurement difficulty and error due to different relative positions of permanent magnet and magnetometer on the device under test (DUT when using the original magnetic measurement method. After fixedly connecting the fluxgate probe with the DUT during the test, the angular displacement due to vibration can be deduced by measuring the geomagnetic field’s magnetic induction intensity change on the orthogonal three components during the vibration. The test shows that the microvibration sensor has angular resolution of over 0.05° and maximum measuring frequency of 64 Hz. As an exploring test aimed to detect the microvibration of earth-orbiting satellite in the in-orbit process, the simulation experiment successfully provides the real-time microvibration information for attitude and orbit control subsystem.

  7. Results from the GSFC fluxgate magnetometer on Pioneer 11

    Science.gov (United States)

    Acuna, M. H.; Ness, N. F.

    1976-01-01

    A high-field triaxial fluxgate magnetometer was mounted on Pioneer 11 to measure the main magnetic field of Jupiter. It is found that this planetary magnetic field is more complex than that indicated by the results of the Pioneer 10 vector helium magnetometer. At distances less than 3 Jupiter radii, the magnetic field is observed to increase more rapidly than an inverse-cubed distance law associated with any simple dipole model. Contributions from higher-order multipoles are significant, with the quadrupole and octupole being 24 and 21 percent of the dipole moment, respectively. Implications of the results for the study of trapped particles, planetary radio emission, and planetary interiors are discussed. Major conclusions are that the deviation of the main planetary magnetic field from a simple dipole leads to distortion of the L shells of the charged particles and to warping of the magnetic equator. Enhanced absorption effects associated with Amalthea and Io are predicted.

  8. Mapping of Ambient Magnetic Fields within Liquid Helium Dewar for Testing of a DC SQUID Magnetometer

    International Nuclear Information System (INIS)

    Newhouse, Randal

    2003-01-01

    In an effort to explore the cavity lights phenomenon, Experimental Facilities Department at SLAC is testing a DC SQUID magnetometer. Due to the nature of the SQUID magnetometer and the intended tests, the earth's magnetic field must be negated. It is proposed to reduce ambient fields using bucking coils. First, however, an accurate map of the magnetic field inside the liquid helium Dewar where the experiment is going to take place needed to be made. This map was made using a three-axis fluxgate magnetometer mounted on a 3D positioning device made for this purpose. A ten inch tall volume within the Dewar was measured at data points approximately an inch from each other in all three axes. A LabVEIW program took readings from the magnetometer at 2 ms intervals for 1000 readings in such a way as to eliminate any ambient 60 Hz signals that may be present in the data. This data was stored in spreadsheet format and was analyzed to determine how the magnetic field within the Dewar was changing as a function of position

  9. Small fluxgate magnetometers: development and future trends in Spain.

    Science.gov (United States)

    Ciudad, David; Díaz-Michelena, Marina; Pérez, Lucas; Aroca, Claudio

    2010-01-01

    In this paper, we give an overview of the research on fluxgate magnetometers carried out in Spain. In particular we focus in the development of the planar-type instruments. We summarize the fabrication processes and signal processing developments as well as their use in complex systems and space.

  10. Small Fluxgate Magnetometers: Development and Future Trends in Spain

    OpenAIRE

    Lucas Pérez; Claudio Aroca; Marina Díaz-Michelena; David Ciudad

    2010-01-01

    In this paper, we give an overview of the research on fluxgate magnetometers carried out in Spain. In particular we focus in the development of the planar-type instruments. We summarize the fabrication processes and signal processing developments as well as their use in complex systems and space.

  11. Corrosion measurement using flux gate magnetometer

    International Nuclear Information System (INIS)

    Rashdi Shah Ahmad; Chong Cheong Wei

    2001-01-01

    The ability of fluxgate magnetometer to detect and measure quantitatively the magnetic field generated by electrochemical corrosion is presented. In this study, each sample (iron plate) was exposed to a range of increasingly corrosive environment. During the exposure, we measured the magnetic field above the sample for specific duration of time. The result shows that there is a clear relationship between corrosivity of the environment and the change in magnitude of magnetic field that was generated by the corrosion reaction. Therefore, the measurement of magnetic field might be used to determine the corrosion rates. (Author)

  12. High-sensitivity low-noise miniature fluxgate magnetometers using a flip chip conceptual design.

    Science.gov (United States)

    Lu, Chih-Cheng; Huang, Jeff; Chiu, Po-Kai; Chiu, Shih-Liang; Jeng, Jen-Tzong

    2014-07-30

    This paper presents a novel class of miniature fluxgate magnetometers fabricated on a print circuit board (PCB) substrate and electrically connected to each other similar to the current "flip chip" concept in semiconductor package. This sensor is soldered together by reversely flipping a 5 cm × 3 cm PCB substrate to the other identical one which includes dual magnetic cores, planar pick-up coils, and 3-D excitation coils constructed by planar Cu interconnections patterned on PCB substrates. Principles and analysis of the fluxgate sensor are introduced first, and followed by FEA electromagnetic modeling and simulation for the proposed sensor. Comprehensive characteristic experiments of the miniature fluxgate device exhibit favorable results in terms of sensitivity (or "responsivity" for magnetometers) and field noise spectrum. The sensor is driven and characterized by employing the improved second-harmonic detection technique that enables linear V-B correlation and responsivity verification. In addition, the double magnitude of responsivity measured under very low frequency (1 Hz) magnetic fields is experimentally demonstrated. As a result, the maximum responsivity of 593 V/T occurs at 50 kHz of excitation frequency with the second harmonic wave of excitation; however, the minimum magnetic field noise is found to be 0.05 nT/Hz(1/2) at 1 Hz under the same excitation. In comparison with other miniature planar fluxgates published to date, the fluxgate magnetic sensor with flip chip configuration offers advances in both device functionality and fabrication simplicity. More importantly, the novel design can be further extended to a silicon-based micro-fluxgate chip manufactured by emerging CMOS-MEMS technologies, thus enriching its potential range of applications in modern engineering and the consumer electronics market.

  13. Small Fluxgate Magnetometers: Development and Future Trends in Spain

    Science.gov (United States)

    Ciudad, David; Díaz-Michelena, Marina; Pérez, Lucas; Aroca, Claudio

    2010-01-01

    In this paper, we give an overview of the research on fluxgate magnetometers carried out in Spain. In particular we focus in the development of the planar-type instruments. We summarize the fabrication processes and signal processing developments as well as their use in complex systems and space. PMID:22294904

  14. Small Fluxgate Magnetometers: Development and Future Trends in Spain

    Directory of Open Access Journals (Sweden)

    Lucas Pérez

    2010-03-01

    Full Text Available In this paper, we give an overview of the research on fluxgate magnetometers carried out in Spain. In particular we focus in the development of the planar-type instruments. We summarize the fabrication processes and signal processing developments as well as their use in complex systems and space.

  15. Quantifying the In-Flight Yaw, Pitch, and Roll of a Semi-Rigidly Mounted Potassium Vapour Magnetometer Suspended Under a Heavy-Lift Multi-Rotor UAV and its Impact on Data Quality

    Science.gov (United States)

    Walter, C. A.; Braun, A.; Fotopoulos, G.

    2017-12-01

    Research is being conducted to develop an Unmanned Aerial System (UAS) that is capable of reliably and efficiently collecting high resolution, industry standard magnetic data (magnetic data with a fourth difference of +/- 0.05 nT) via an optically pumped vapour magnetometer. The benefits of developing a UAS with these capabilities include improvements in the resolution of localized airborne surveys (2.5 km by 2.5 km) and the ability to conduct 3D magnetic gradiometry surveys in the observation gap evident between traditional terrestrial and manned airborne magnetic surveys (surface elevation up to 120 m). Quantifying the extent of an optically pumped vapour magnetometer's 3D orientation variations, while in-flight and suspended under a UAS, is a significant advancement to existing knowledge as optically pumped magnetometers have an orientation-dependent (to the primary magnetic field vector) process for measuring the magnetic field. This study investigates the orientation characteristics of a GEM Systems potassium vapour magnetometer, GSMP-35U, while semi-rigidly suspended 3 m under a DJI S900, heavy-lift multi-rotor UAV (Unmanned Aerial Vehicle) during an airborne surveying campaign conducted Northeast of Thunder Bay, Ontario, Canada. A nine degrees of freedom IMU (Inertial Measurement Unit), the Adafruit GY-80, was used to quantify the 3D orientation variations (yaw, pitch and roll) of the magnetic sensor during flight. The orientation and magnetic datasets were indexed and linked with a date and time stamp (within 1 ms) via a Raspberry Pi 2, acting as an on-board computer and data storage system. Analysing the two datasets allowed for the in-flight orientation variations of the potassium vapour magnetometer to be directly compared with the gathered magnetic and signal quality data of the magnetometer. The in-flight orientation characteristics of the magnetometer were also quantified for a range of air-speeds and flight maneuvers throughout the survey. Overall

  16. Development of a {sup 3}He magnetometer for a neutron electric dipole moment experiment

    Energy Technology Data Exchange (ETDEWEB)

    Kraft, Andreas; Heil, Werner; Lauer, Thorsten; Neumann, Daniel [Johannes Gutenberg University, Institute of Physics, Mainz (Germany); Koch, Hans-Christian [Johannes Gutenberg University, Institute of Physics, Mainz (Germany); University of Fribourg, Physics Department, Fribourg (Switzerland); Daum, Manfred [Paul Scherrer Institute, Villigen (Switzerland); Pazgalev, Anatoly [Ioffe Institute, St Petersburg (Russian Federation); Sobolev, Yuri [Johannes Gutenberg University, Institute of Nuclear Chemistry, Mainz (Germany); Petersburg Nuclear Physics Institute, Gatchina (Russian Federation); Weis, Antoine [University of Fribourg, Physics Department, Fribourg (Switzerland)

    2014-01-01

    We have developed a highly sensitive {sup 3}He magnetometer for the accurate measurement of the magnetic field in an experiment searching for an electric dipole moment of the neutron. By measuring the Larmor frequency of nuclear spin polarized {sup 3}He atoms a sensitivity on the femto-Tesla scale can be achieved. A {sup 3}He/Cs-test facility was established at the Institute of Physics of the Johannes Gutenberg University in Mainz to investigate the readout of {sup 3}He free induction decay with a lamp-pumped Cs magnetometer. For this we designed and built an ultra-compact and transportable polarizer unit which polarizes {sup 3}He gas up to 55% by metastability exchange optical pumping. The polarized {sup 3}He was successfully transfered from the polarizer into a glass cell mounted in a magnetic shield and the {sup 3}He free induction decay was detected by a lamp-pumped Cs magnetometer. (orig.)

  17. Ionospheric travelling convection vortices observed by the Greenland magnetometer chain

    DEFF Research Database (Denmark)

    Kotsiaros, Stavros; Stolle, Claudia; Friis-Christensen, Eigil

    2013-01-01

    The Greenland magnetometer array continuously provides geomagnetic variometer data since the early eighties. With the polar cusp passing over it almost every day, the array is suitable to detect ionospheric traveling convection vortices (TCVs), which were rst detected by Friis-Christensen et al...

  18. Multi-flux-transformer MRI detection with an atomic magnetometer.

    Science.gov (United States)

    Savukov, Igor; Karaulanov, Todor

    2014-12-01

    Recently, anatomical ultra-low field (ULF) MRI has been demonstrated with an atomic magnetometer (AM). A flux-transformer (FT) has been used for decoupling MRI fields and gradients to avoid their negative effects on AM performance. The field of view (FOV) was limited because of the need to compromise between the size of the FT input coil and MRI sensitivity per voxel. Multi-channel acquisition is a well-known solution to increase FOV without significantly reducing sensitivity. In this paper, we demonstrate twofold FOV increase with the use of three FT input coils. We also show that it is possible to use a single atomic magnetometer and single acquisition channel to acquire three independent MRI signals by applying a frequency-encoding gradient along the direction of the detection array span. The approach can be generalized to more channels and can be critical for imaging applications of non-cryogenic ULF MRI where FOV needs to be large, including head, hand, spine, and whole-body imaging. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Fluxgate Magnetometer system mounted on UAS system: First field test at Dominga IOCG deposit, Chile

    Science.gov (United States)

    Yanez, G. A.; Banchero, L.; Marco, A.; Figueroa, R.

    2016-12-01

    With the support of Fundacion Chile (FCH) grant, we developed an airborne magnetic system (GeoMagDrone GFDAS) mounted on a UAS octodrone platform (DJI, S1000), based on a low cost/light-weight fluxgate magnetometer (FGM-301) and a robust/light-weight data logger for position, temperature, radar altimeter and 3 magnetic components at 16 Hz recording. Fluxgate magnetometer is hanging from the UAS platform at a distance of 2.5m where the EM noise is reduced to less than 2 nT. The whole geophysical system, including batteries, weights 650 gr., with an autonomy of 2 hours. Magnetometer calibration includes the 9 coefficients of amplitude, offset, and orthogonality, and temperature correction. We test the system over the IOCG deposit of Dominga-Chile, a magnetite ore (40%) (a block of 2x3 km with NS lines separated every 50m and a clearance of 40m, the mineral deposit buried 50-100m from the surface, where a ground magnetic survey was conducted previously. Ground conditions includes relatively rough topography with slopes of 10-20%, and some windy days. We use the digital terrain model SRTM30 to define the drape flight shape Average flight performance includes a mean speed of 35-40 km/hour, and an UAS battery consumption of 18-12 minutes depending on the wind conditions. A good correspondence was found between plan deployment and survey results in terms of line direction/separation/clearance. Line path were flown with errors less than 5 meters, whereas clearance of 40m was kept depending on the amount of control points used. The comparison between ground survey and GeoMagDrone results show a perfect match (anomaly amplitude/shape and noise envelope), validating in this way the system developed. Main concern for the productive application of this technology in unmanned geophysical platforms is the battery performance and the quality of digital terrain models to follow the topography.

  20. Magnetometer-inferred, Equatorial, Daytime Vertical ExB Drift Velocities Observed in the African Longitude Sector

    Science.gov (United States)

    Anderson, D. N.; Yizengaw, E.

    2011-12-01

    A recent paper has investigated the sharp longitude gradients in the dayside ExB drift velocities associated with the 4-cell, non-migrating structures thought to be connected with the eastward propagating, diurnal, non-migrating (DE3) tides. Observations of vertical ExB drift velocities obtained from the Ion Velocity Meter (IVM) on the Communication/Navigation Outage Forecast System (C/NOFS) satellite were obtained in the Western Pacific, Eastern Pacific, Peruvian and Atlantic sectors for a few days during the months of October, March and December, 2009. Respective ExB drift velocity gradients at the cell boundaries for these 4 longitude sectors were a.) -1.3m/sec/degree, b.) 3m/sec/degree, c.) -4m/sec/degree and d.) 1m/sec/degree and were observed on a day-to-day basis. In this talk, we estimate the longitude gradients in the dayside, vertical ExB drift velocities from magnetometer H-component observations in the African sector. We briefly describe the technique for obtaining realistic ExB drift velocities associated with the difference in the H-component values between a magnetometer on the magnetic equator and one off the magnetic equator at 6 to 9 degrees dip latitude (delta H). We present magnetometer-inferred, dayside ExB drift velocities obtained from the AMBER (African Meridian B-field Education and Research) magnetometer chain in the East Africa (Ethiopian) longitude sector and the West African (Nigerian) longitude sector. We compare the longitude gradients in ExB drift velocities in the African sector with the C/NOFS- observed longitude gradients mentioned above. We also discuss the advantages of using ground-based magnetometer observations to infer ExB drift velocities compared with the C/NOFS satellite observations.

  1. Observations of interplanetary dust by the Juno magnetometer investigation

    DEFF Research Database (Denmark)

    Benn, Mathias; Jørgensen, John Leif; Denver, Troelz

    2017-01-01

    One of the Juno magnetometer investigation's star cameras was configured to search for unidentified objects during Juno's transit en route to Jupiter. This camera detects and registers luminous objects to magnitude 8. Objects persisting in more than five consecutive images and moving with an appa...... on the distribution and motion of interplanetary (>μm sized) dust....

  2. The QuakeFinder Magnetometer Network - a Platform for Earth and Space Science Research

    Science.gov (United States)

    Bleier, T.; Kappler, K. N.; Schneider, D.

    2016-12-01

    QuakeFinder (QF) is a humanitarian research and development project attempting to characterize earth-emitting electromagnetic (EM) signals as potential precursors to earthquakes. Beginning in 2005, QF designed, built, deployed and now maintains an array of 165 remote monitoring stations in 6 countries (US/California, Taiwan, Greece, Indonesia, Peru and Chile). Having amassed approximately 70 TB of data and greater than 140 earthquakes (M4+), QF is focused on the data analysis and signal processing algorithms in our effort to enable a forecasting capability. QF's autonomous stations, located along major fault lines, collect and transmit electromagnetic readings from 3-axis induction magnetometers and positive/negative ion sensors, a geophone, as well as various station health status and local conditions. The induction magnetometers, oriented N-S,E-W and vertically, have a 40 nT range and 1 pT sensitivity. Data is continuously collected at 50 samples/sec (sps), GPS time-stamped and transmitted, primarily through cell phone networks, to our data center in Palo Alto, California. The induction magnetometers routinely detect subtle geomagnetic and ionospheric disturbances as observed worldwide. QF seeks to make available both historic data and the array platform to strategic partners in the EM-related research and operation fields. The QF system will be described in detail with examples of local and regional geomagnetic activity. The stations are robust and will be undergoing a system-level upgrade in the near future. Domestically, QF maintains a 98% `up time' among the 120 stations in California while internationally our metric is typically near 80%. Irregular cell phone reception is chief among the reasons for outages although little data has been lost as the stations can store up to 90 days of data. These data are retrieved by QF personnel or, when communication is reestablished, the QF data ingest process automatically updates the database. Planned station upgrades

  3. Identification of Mobile Phones Using the Built-In Magnetometers Stimulated by Motion Patterns

    Directory of Open Access Journals (Sweden)

    Gianmarco Baldini

    2017-04-01

    Full Text Available We investigate the identification of mobile phones through their built-in magnetometers. These electronic components have started to be widely deployed in mass market phones in recent years, and they can be exploited to uniquely identify mobile phones due their physical differences, which appear in the digital output generated by them. This is similar to approaches reported in the literature for other components of the mobile phone, including the digital camera, the microphones or their RF transmission components. In this paper, the identification is performed through an inexpensive device made up of a platform that rotates the mobile phone under test and a fixed magnet positioned on the edge of the rotating platform. When the mobile phone passes in front of the fixed magnet, the built-in magnetometer is stimulated, and its digital output is recorded and analyzed. For each mobile phone, the experiment is repeated over six different days to ensure consistency in the results. A total of 10 phones of different brands and models or of the same model were used in our experiment. The digital output from the magnetometers is synchronized and correlated, and statistical features are extracted to generate a fingerprint of the built-in magnetometer and, consequently, of the mobile phone. A SVM machine learning algorithm is used to classify the mobile phones on the basis of the extracted statistical features. Our results show that inter-model classification (i.e., different models and brands classification is possible with great accuracy, but intra-model (i.e., phones with different serial numbers and same model classification is more challenging, the resulting accuracy being just slightly above random choice.

  4. The fluxgate magnetometer of the BepiColombo Mercury Planetary Orbiter

    Science.gov (United States)

    Glassmeier, K.-H.; Auster, H.-U.; Heyner, D.; Okrafka, K.; Carr, C.; Berghofer, G.; Anderson, B. J.; Balogh, A.; Baumjohann, W.; Cargill, P.; Christensen, U.; Delva, M.; Dougherty, M.; Fornaçon, K.-H.; Horbury, T. S.; Lucek, E. A.; Magnes, W.; Mandea, M.; Matsuoka, A.; Matsushima, M.; Motschmann, U.; Nakamura, R.; Narita, Y.; O'Brien, H.; Richter, I.; Schwingenschuh, K.; Shibuya, H.; Slavin, J. A.; Sotin, C.; Stoll, B.; Tsunakawa, H.; Vennerstrom, S.; Vogt, J.; Zhang, T.

    2010-01-01

    The magnetometer (MAG) on the Mercury Planetary Orbiter (MPO) of the joint European-Japanese BepiColombo mission to planet Mercury is a low-noise, tri-axial, dual-sensor, digital fluxgate instrument with its sensors mounted on a 2.8-m-long boom. The primary MPO/MAG science objectives are to determine the spatial and temporal structure of the magnetic field in the Hermean system, in particular the structure and origin of the intrinsic magnetic field of Mercury. MPO/MAG has a dynamic measurement range of ±2000nT with a resolution of 2 pT during operation along the near-polar orbit of the MPO spacecraft around Mercury. MPO/MAG is designed to provide measurements with rates between 0.5 and 128 vectors/s. In cooperation with its sister magnetometer instrument, MMO/MGF on board the BepiColombo Mercury Magnetospheric Orbiter (MMO), MPO/MAG will be able to distinguish between temporal and spatial magnetic field variations in the magnetically closely coupled Hermean system.

  5. Space Weather Magnetometer Set with Automated AC Spacecraft Field Correction for GEO-KOMPSAT-2A

    Science.gov (United States)

    Auster, U.; Magnes, W.; Delva, M.; Valavanoglou, A.; Leitner, S.; Hillenmaier, O.; Strauch, C.; Brown, P.; Whiteside, B.; Bendyk, M.; Hilgers, A.; Kraft, S.; Luntama, J. P.; Seon, J.

    2016-05-01

    Monitoring the solar wind conditions, in particular its magnetic field (interplanetary magnetic field) ahead of the Earth is essential in performing accurate and reliable space weather forecasting. The magnetic condition of the spacecraft itself is a key parameter for the successful performance of the magnetometer onboard. In practice a condition with negligible magnetic field of the spacecraft cannot always be fulfilled and magnetic sources on the spacecraft interfere with the natural magnetic field measured by the space magnetometer. The presented "ready-to-use" Service Oriented Spacecraft Magnetometer (SOSMAG) is developed for use on any satellite implemented without magnetic cleanliness programme. It enables detection of the spacecraft field AC variations on a proper time scale suitable to distinguish the magnetic field variations relevant to space weather phenomena, such as sudden increase in the interplanetary field or southward turning. This is achieved through the use of dual fluxgate magnetometers on a short boom (1m) and two additional AMR sensors on the spacecraft body, which monitor potential AC disturbers. The measurements of the latter sensors enable an automated correction of the AC signal contributions from the spacecraft in the final magnetic vector. After successful development and test of the EQM prototype, a flight model (FM) is being built for the Korean satellite Geo-Kompsat 2A, with launch foreseen in 2018.

  6. The polarization and the fundamental sensitivity of 39K (133Cs)-85Rb-4He hybrid optical pumping spin exchange relaxation free atomic magnetometers.

    Science.gov (United States)

    Liu, Jian-Hua; Jing, Dong-Yang; Wang, Liang-Liang; Li, Yang; Quan, Wei; Fang, Jian-Cheng; Liu, Wu-Ming

    2017-07-28

    The hybrid optical pumping spin exchange relaxation free (SERF) atomic magnetometers can realize ultrahigh sensitivity measurement of magnetic field and inertia. We have studied the 85 Rb polarization of two types of hybrid optical pumping SERF magnetometers based on 39 K- 85 Rb- 4 He and 133 Cs- 85 Rb- 4 He respectively. Then we found that 85 Rb polarization varies with the number density of buffer gas 4 He and quench gas N 2 , pumping rate of pump beam and cell temperature respectively, which will provide an experimental guide for the design of the magnetometer. We obtain a general formula on the fundamental sensitivity of the hybrid optical pumping SERF magnetometer due to shot-noise. The formula describes that the fundamental sensitivity of the magnetometer varies with the number density of buffer gas and quench gas, the pumping rate of pump beam, external magnetic field, cell effective radius, measurement volume, cell temperature and measurement time. We obtain a highest fundamental sensitivity of 1.5073 aT/Hz 1/2 (1 aT = 10 -18 T) with 39 K- 85 Rb- 4 He magnetometer between above two types of magnetometers when 85 Rb polarization is 0.1116. We estimate the fundamental sensitivity limit of the hybrid optical pumping SERF magnetometer to be superior to 1.8359 × 10 -2 aT/Hz 1/2 , which is higher than the shot-noise-limited sensitivity of 1 aT/Hz 1/2 of K SERF atomic magnetometer.

  7. Vector magnetometer design study: Analysis of a triaxial fluxgate sensor design demonstrates that all MAGSAT Vector Magnetometer specifications can be met

    Science.gov (United States)

    Adams, D. F.; Hartmann, U. G.; Lazarow, L. L.; Maloy, J. O.; Mohler, G. W.

    1976-01-01

    The design of the vector magnetometer selected for analysis is capable of exceeding the required accuracy of 5 gamma per vector field component. The principal elements that assure this performance level are very low power dissipation triaxial feedback coils surrounding ring core flux-gates and temperature control of the critical components of two-loop feedback electronics. An analysis of the calibration problem points to the need for improved test facilities.

  8. Automated system for the calibration of magnetometers

    DEFF Research Database (Denmark)

    Petrucha, Vojtech; Kaspar, Petr; Ripka, Pavel

    2009-01-01

    A completely nonmagnetic calibration platform has been developed and constructed at DTU Space (Technical University of Denmark). It is intended for on-site scalar calibration of high-precise fluxgate magnetometers. An enhanced version of the same platform is being built at the Czech Technical Uni...... through custom-made optical incremental sensors. The system is controlled by a microcontroller, which executes commands from a computer. The properties of the system as well as calibration and measurement results will be presented. ©2009 American Institute of Physics...

  9. High-Sensitivity Low-Noise Miniature Fluxgate Magnetometers Using a Flip Chip Conceptual Design

    Directory of Open Access Journals (Sweden)

    Chih-Cheng Lu

    2014-07-01

    Full Text Available This paper presents a novel class of miniature fluxgate magnetometers fabricated on a print circuit board (PCB substrate and electrically connected to each other similar to the current “flip chip” concept in semiconductor package. This sensor is soldered together by reversely flipping a 5 cm × 3 cm PCB substrate to the other identical one which includes dual magnetic cores, planar pick-up coils, and 3-D excitation coils constructed by planar Cu interconnections patterned on PCB substrates. Principles and analysis of the fluxgate sensor are introduced first, and followed by FEA electromagnetic modeling and simulation for the proposed sensor. Comprehensive characteristic experiments of the miniature fluxgate device exhibit favorable results in terms of sensitivity (or “responsivity” for magnetometers and field noise spectrum. The sensor is driven and characterized by employing the improved second-harmonic detection technique that enables linear V-B correlation and responsivity verification. In addition, the double magnitude of responsivity measured under very low frequency (1 Hz magnetic fields is experimentally demonstrated. As a result, the maximum responsivity of 593 V/T occurs at 50 kHz of excitation frequency with the second harmonic wave of excitation; however, the minimum magnetic field noise is found to be 0.05 nT/Hz1/2 at 1 Hz under the same excitation. In comparison with other miniature planar fluxgates published to date, the fluxgate magnetic sensor with flip chip configuration offers advances in both device functionality and fabrication simplicity. More importantly, the novel design can be further extended to a silicon-based micro-fluxgate chip manufactured by emerging CMOS-MEMS technologies, thus enriching its potential range of applications in modern engineering and the consumer electronics market.

  10. High-Sensitivity Low-Noise Miniature Fluxgate Magnetometers Using a Flip Chip Conceptual Design

    Science.gov (United States)

    Lu, Chih-Cheng; Huang, Jeff; Chiu, Po-Kai; Chiu, Shih-Liang; Jeng, Jen-Tzong

    2014-01-01

    This paper presents a novel class of miniature fluxgate magnetometers fabricated on a print circuit board (PCB) substrate and electrically connected to each other similar to the current “flip chip” concept in semiconductor package. This sensor is soldered together by reversely flipping a 5 cm × 3 cm PCB substrate to the other identical one which includes dual magnetic cores, planar pick-up coils, and 3-D excitation coils constructed by planar Cu interconnections patterned on PCB substrates. Principles and analysis of the fluxgate sensor are introduced first, and followed by FEA electromagnetic modeling and simulation for the proposed sensor. Comprehensive characteristic experiments of the miniature fluxgate device exhibit favorable results in terms of sensitivity (or “responsivity” for magnetometers) and field noise spectrum. The sensor is driven and characterized by employing the improved second-harmonic detection technique that enables linear V-B correlation and responsivity verification. In addition, the double magnitude of responsivity measured under very low frequency (1 Hz) magnetic fields is experimentally demonstrated. As a result, the maximum responsivity of 593 V/T occurs at 50 kHz of excitation frequency with the second harmonic wave of excitation; however, the minimum magnetic field noise is found to be 0.05 nT/Hz1/2 at 1 Hz under the same excitation. In comparison with other miniature planar fluxgates published to date, the fluxgate magnetic sensor with flip chip configuration offers advances in both device functionality and fabrication simplicity. More importantly, the novel design can be further extended to a silicon-based micro-fluxgate chip manufactured by emerging CMOS-MEMS technologies, thus enriching its potential range of applications in modern engineering and the consumer electronics market. PMID:25196107

  11. Rad-Hard Sigma-Delta 3-Channel ADC for Fluxgate Magnetometers, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The measurement of the magnetic field vector is of fundamental importance to space physics missions. The fluxgate magnetometer is a device developed for precise...

  12. MgB2 magnetometer with directly coupled pick-up loop

    NARCIS (Netherlands)

    Portesi, C.; Mijatovic, D.; Veldhuis, Dick; Brinkman, Alexander; Monticone, E.; Gonnelli, R.S.

    2006-01-01

    magnetometer with a directly coupled pick-up loop. We used an all in situ technique for fabricating magnesium diboride films, which consists of the co-evaporation of B and Mg by means of an e-gun and a resistive heater respectively. Consequently, we realized the superconducting device, which

  13. Micromechanical ``Trampoline'' Magnetometers for Use in Pulsed Magnetic Fields Exceeding 60 Tesla

    Science.gov (United States)

    Balakirev, F. F.; Boebinger, G. S.; Aksyuk, V.; Gammel, P. L.; Haddon, R. C.; Bishop, D. J.

    1998-03-01

    We present the design, construction, and operation of a novel magnetometer for use in intense pulsed magnetic fields. The magnetometer consists of a silicon micromachined "trampoline" to which the sample is attached. The small size of the device (typically 400 microns on a side) gives a fast mechanical response (10,000 to 50,000 Hz) and extremely high sensitivity (10-11 Am^2, corresponding to 10-13 Am^2/Hz^(1/2)). The device is robust against electrical and mechanical noise and requires no special vibration isolation from the pulsed magnet. As a demonstration, we present data taken in a 60 tesla pulsed magnetic field which show clear de Haas-van Alphen oscillations in a one microgram sample of the organic superconductor K-(BEDT-TTF)_2Cu(NCS)_2.

  14. Magnetisation reversal on surface of Nd-Fe-B magnets

    International Nuclear Information System (INIS)

    Sun, H.; Woodward, R.; Street, R.

    1998-01-01

    Full text: Time dependent magnetisation processes on surface of isotropic and anisotropic Nd-Fe-B magnets were measured using a Magneto-Optic Magnetometer (MOM) and the data were analysed by means of the constitutive equation H = H(M, M). The surface magnetic viscosity parameter Λ (or fluctuation field H f ) was obtained. The activation volume v, which represents the volume of a negative magnetisation nuclei during a magnetisation reversal process was calculated from Λ. The results are compared with those of the corresponding bulk properties obtained by analysing the data measured using a Vibrating Sample Magnetometer (VSM). Similar to bulk materials, Λ for the surface magnetisation is nearly constant over a wide range of magnetisation for both isotropic and anisotropic Nd-Fe-B. However, the surface hysteresis loops are significantly different from the bulk materials, indicating a significant difference in the magnetisation reversal processes between the bulk and surface materials. The surface magnetisation reversal mechanism, its relation and influence to the bulk properties and therefore the performance of permanent magnet are discussed

  15. Temperature-dependent performance of all-NbN DC-SQUID magnetometers

    Science.gov (United States)

    Liu, Quansheng; Wang, Huiwu; Zhang, Qiyu; Wang, Hai; Peng, Wei; Wang, Zhen

    2017-05-01

    Integrated NbN direct current superconducting quantum interference device (DC-SQUID) magnetometers were developed based on high-quality epitaxial NbN/AlN/NbN Josephson junctions for SQUID applications operating at high temperatures. We report the current-voltage and voltage-flux characteristics and the noise performance of the NbN DC-SQUIDs for temperatures ranging from 4.2 to 9 K. The critical current and voltage swing of the DC-SQUIDs decreased by 15% and 25%, respectively, as the temperature was increased from 4.2 to 9 K. The white flux noise of the DC-SQUID magnetometer at 1 kHz increased from 3.9 μΦ0/Hz1/2 at 4.2 K to 4.8 μΦ0/Hz1/2 at 9 K with 23% increase, corresponding to the magnetic field noise of 6.6 and 8.1 fT/Hz1/2, respectively. The results show that NbN DC-SQUIDs improve the tolerance of the operating temperatures and temperature fluctuations in SQUID applications.

  16. New vector/scalar Overhauser DNP magnetometers POS-4 for magnetic observatories and directional oil drilling support

    Directory of Open Access Journals (Sweden)

    Sapunov V.A., Denisov A.Y., Saveliev D.V., Soloviev A.A., Khomutov S.Y., Borodin P.B., Narkhov E.D., Sergeev A.V., Shirokov A.N.

    2016-12-01

    Full Text Available This paper covers same results of the research directed at developing an absolute vector proton magnetometer POS-4 based on the switching bias magnetic fields methods. Due to the high absolute precision and stability magnetometer POS-4 found application not only for observatories and to directional drilling support of oi and gas well. Also we discuss the some basic errors of measurements and discuss the long-term experience in the testing of magnetic observatories ART and PARATUNKA.

  17. The MAGIC of CINEMA: first in-flight science results from a miniaturised anisotropic magnetoresistive magnetometer

    Science.gov (United States)

    Archer, M. O.; Horbury, T. S.; Brown, P.; Eastwood, J. P.; Oddy, T. M.; Whiteside, B. J.; Sample, J. G.

    2015-06-01

    We present the first in-flight results from a novel miniaturised anisotropic magnetoresistive space magnetometer, MAGIC (MAGnetometer from Imperial College), aboard the first CINEMA (CubeSat for Ions, Neutrals, Electrons and MAgnetic fields) spacecraft in low Earth orbit. An attitude-independent calibration technique is detailed using the International Geomagnetic Reference Field (IGRF), which is temperature dependent in the case of the outboard sensor. We show that the sensors accurately measure the expected absolute field to within 2% in attitude mode and 1% in science mode. Using a simple method we are able to estimate the spacecraft's attitude using the magnetometer only, thus characterising CINEMA's spin, precession and nutation. Finally, we show that the outboard sensor is capable of detecting transient physical signals with amplitudes of ~ 20-60 nT. These include field-aligned currents at the auroral oval, qualitatively similar to previous observations, which agree in location with measurements from the DMSP (Defense Meteorological Satellite Program) and POES (Polar-orbiting Operational Environmental Satellites) spacecraft. Thus, we demonstrate and discuss the potential science capabilities of the MAGIC instrument onboard a CubeSat platform.

  18. Suppression of the Nonlinear Zeeman Effect and Heading Error in Earth-Field-Range Alkali-Vapor Magnetometers.

    Science.gov (United States)

    Bao, Guzhi; Wickenbrock, Arne; Rochester, Simon; Zhang, Weiping; Budker, Dmitry

    2018-01-19

    The nonlinear Zeeman effect can induce splitting and asymmetries of magnetic-resonance lines in the geophysical magnetic-field range. This is a major source of "heading error" for scalar atomic magnetometers. We demonstrate a method to suppress the nonlinear Zeeman effect and heading error based on spin locking. In an all-optical synchronously pumped magnetometer with separate pump and probe beams, we apply a radio-frequency field which is in phase with the precessing magnetization. This results in the collapse of the multicomponent asymmetric magnetic-resonance line with ∼100  Hz width in the Earth-field range into a single peak with a width of 22 Hz, whose position is largely independent of the orientation of the sensor within a range of orientation angles. The technique is expected to be broadly applicable in practical magnetometry, potentially boosting the sensitivity and accuracy of Earth-surveying magnetometers by increasing the magnetic-resonance amplitude, decreasing its width, and removing the important and limiting heading-error systematic.

  19. Suppression of the Nonlinear Zeeman Effect and Heading Error in Earth-Field-Range Alkali-Vapor Magnetometers

    Science.gov (United States)

    Bao, Guzhi; Wickenbrock, Arne; Rochester, Simon; Zhang, Weiping; Budker, Dmitry

    2018-01-01

    The nonlinear Zeeman effect can induce splitting and asymmetries of magnetic-resonance lines in the geophysical magnetic-field range. This is a major source of "heading error" for scalar atomic magnetometers. We demonstrate a method to suppress the nonlinear Zeeman effect and heading error based on spin locking. In an all-optical synchronously pumped magnetometer with separate pump and probe beams, we apply a radio-frequency field which is in phase with the precessing magnetization. This results in the collapse of the multicomponent asymmetric magnetic-resonance line with ˜100 Hz width in the Earth-field range into a single peak with a width of 22 Hz, whose position is largely independent of the orientation of the sensor within a range of orientation angles. The technique is expected to be broadly applicable in practical magnetometry, potentially boosting the sensitivity and accuracy of Earth-surveying magnetometers by increasing the magnetic-resonance amplitude, decreasing its width, and removing the important and limiting heading-error systematic.

  20. Evaluating detection and estimation capabilities of magnetometer-based vehicle sensors

    Science.gov (United States)

    Slater, David M.; Jacyna, Garry M.

    2013-05-01

    In an effort to secure the northern and southern United States borders, MITRE has been tasked with developing Modeling and Simulation (M&S) tools that accurately capture the mapping between algorithm-level Measures of Performance (MOP) and system-level Measures of Effectiveness (MOE) for current/future surveillance systems deployed by the the Customs and Border Protection Office of Technology Innovations and Acquisitions (OTIA). This analysis is part of a larger M&S undertaking. The focus is on two MOPs for magnetometer-based Unattended Ground Sensors (UGS). UGS are placed near roads to detect passing vehicles and estimate properties of the vehicle's trajectory such as bearing and speed. The first MOP considered is the probability of detection. We derive probabilities of detection for a network of sensors over an arbitrary number of observation periods and explore how the probability of detection changes when multiple sensors are employed. The performance of UGS is also evaluated based on the level of variance in the estimation of trajectory parameters. We derive the Cramer-Rao bounds for the variances of the estimated parameters in two cases: when no a priori information is known and when the parameters are assumed to be Gaussian with known variances. Sample results show that UGS perform significantly better in the latter case.

  1. Fluxgate magnetometer offset vector determination by the 3D mirror mode method

    Science.gov (United States)

    Plaschke, F.; Goetz, C.; Volwerk, M.; Richter, I.; Frühauff, D.; Narita, Y.; Glassmeier, K.-H.; Dougherty, M. K.

    2017-07-01

    Fluxgate magnetometers on-board spacecraft need to be regularly calibrated in flight. In low fields, the most important calibration parameters are the three offset vector components, which represent the magnetometer measurements in vanishing ambient magnetic fields. In case of three-axis stabilized spacecraft, a few methods exist to determine offsets: (I) by analysis of Alfvénic fluctuations present in the pristine interplanetary magnetic field, (II) by rolling the spacecraft around at least two axes, (III) by cross-calibration against measurements from electron drift instruments or absolute magnetometers, and (IV) by taking measurements in regions of well-known magnetic fields, e.g. cometary diamagnetic cavities. In this paper, we introduce a fifth option, the 3-dimensional (3D) mirror mode method, by which 3D offset vectors can be determined using magnetic field measurements of highly compressional waves, e.g. mirror modes in the Earth's magnetosheath. We test the method by applying it to magnetic field data measured by the following: the Time History of Events and Macroscale Interactions during Substorms-C spacecraft in the terrestrial magnetosheath, the Cassini spacecraft in the Jovian magnetosheath and the Rosetta spacecraft in the vicinity of comet 67P/Churyumov-Gerasimenko. The tests reveal that the achievable offset accuracies depend on the ambient magnetic field strength (lower strength meaning higher accuracy), on the length of the underlying data interval (more data meaning higher accuracy) and on the stability of the offset that is to be determined.

  2. On-orbit real-time magnetometer bias determination for micro-satellites without attitude information

    Directory of Open Access Journals (Sweden)

    Zhang Zhen

    2015-10-01

    Full Text Available Due to the disadvantages such as complex calculation, low accuracy of estimation, and being non real time in present methods, a new real-time algorithm is developed for on-orbit magnetometer bias determination of micro-satellites without attitude knowledge in this paper. This method uses the differential value approach. It avoids the impact of quartic nature and uses the iterative method to satisfy real-time applications. Simulation results indicate that the new real-time algorithm is more accurate compared with other methods, which are also tested by an experiment system using real noise data. With the new real-time algorithm, a magnetometer calibration can be taken on-orbit and will reduce the demand for computing power effectively.

  3. Searching for axion stars and Q-balls with a terrestrial magnetometer network

    Energy Technology Data Exchange (ETDEWEB)

    Jackson Kimball, D. F. [Cal State, East Bay; Budker, D. [UC, Berkeley; Eby, J. [Fermilab; Pospelov, M. [Perimeter Inst. Theor. Phys.; Pustelny, S. [Jagiellonian U.; Scholtes, T. [Fribourg U.; Stadnik, Y. V. [Helmholtz Inst., Mainz; Weis, A. [Fribourg U.; Wickenbrock, A. [Mainz U.

    2017-10-11

    Light (pseudo-)scalar fields are promising candidates to be the dark matter in the Universe. Under certain initial conditions in the early Universe and/or with certain types of self-interactions, they can form compact dark-matter objects such as axion stars or Q-balls. Direct encounters with such objects can be searched for by using a global network of atomic magnetometers. It is shown that for a range of masses and radii not ruled out by existing observations, the terrestrial encounter rate with axion stars or Q-balls can be sufficiently high (at least once per year) for a detection. Furthermore, it is shown that a global network of atomic magnetometers is sufficiently sensitive to pseudoscalar couplings to atomic spins so that a transit through an axion star or Q-ball could be detected over a broad range of unexplored parameter space.

  4. Venus Lightning: What We Have Learned from the Venus Express Fluxgate Magnetometer

    Science.gov (United States)

    Russell, C. T.; Strangeway, R. J.; Wei, H. Y.; Zhang, T. L.

    2010-03-01

    The Venus Express magnetometer sees short (tens of milliseconds) pulses of EM waves in the Venus ionosphere as predicted by the lightning model for the PVO electric pulses. These waves are stronger than similar terrestrial signals produced by lightning.

  5. Exploiting nonlinear dynamics in a coupled-core fluxgate magnetometer

    International Nuclear Information System (INIS)

    Bulsara, Adi R; In, Visarath; Kho, Andy; Longhini, Patrick; Neff, Joe; Anderson, Gregory; Obra, Christopher; Palacios, Antonio; Baglio, Salvatore; Ando, Bruno

    2008-01-01

    Unforced bistable dynamical systems having dynamics of the general form τ F x-dot (t)=-∇ x U(x) cannot oscillate (i.e. switch between their stable attractors). However, a number of such systems subject to carefully crafted coupling schemes have been shown to exhibit oscillatory behavior under carefully chosen operating conditions. This behavior, in turn, affords a new mechanism for the detection and quantification of target signals having magnitude far smaller than the energy barrier height in the potential energy function U(x) for a single (uncoupled) element. The coupling-induced oscillations are a feature that appears to be universal in systems described by bi- or multi-stable potential energy functions U(x), and are being exploited in a new class of dynamical sensors being developed by us. In this work we describe one of these devices, a coupled-core fluxgate magnetometer (CCFM), whose operation is underpinned by this dynamic behavior. We provide an overview of the underlying dynamics and, also, quantify the performance of our test device; in particular, we provide a quantitative performance comparison to a conventional (single-core) fluxgate magnetometer via a 'resolution' parameter that embodies the device sensitivity (the slope of its input–output transfer characteristic) as well as the noise floor

  6. Magnetogate: Using an iPhone Magnetometer for Measuring Kinematic Variables

    Science.gov (United States)

    Temiz, Burak Kagan; Yavuz, Ahmet

    2016-01-01

    This paper presents a method to measure the movement of an object from specific locations on a straight line using an iPhone's magnetometer. In this method, called "magnetogate," an iPhone is placed on a moving object (in this case a toy car) and small neodymium magnets are arranged at equal intervals on one side of a straight line. The…

  7. Surface and interior of Venus

    Energy Technology Data Exchange (ETDEWEB)

    Masursky, H [U.S. Geological Survey, Flagstaff, Arizona, USA; Kaula, W M [California Univ., Los Angeles (USA); McGill, G E [Massachusetts Univ., Amherst (USA); Pettengill, G H; Shapiro, I I [Massachusetts Inst. of Tech., Cambridge (USA). Dept. of Earth and Planetary Sciences; Phillips, R J [Jet Propulsion Lab., Pasadena, Calif. (USA); Russell, C T [California Univ., Los Angeles (USA). Inst. of Geophysics and Planetary Physics; Schubert, G [California Univ., Los Angeles (USA)

    1977-06-01

    Present ideas about the surface and interior of Venus are based on data obtained from (1) Earth-based radio and radar: temperature, rotation, shape, and topography; (2) fly-by and orbiting spacecraft: gravity and magnetic fields; and (3) landers: winds, local structure, gamma radiation. Surface features, including large basins, crater-like depressions, and a linear valley, have been recognized from recent ground-based radar images. Pictures of the surface acquired by the USSR's Venera 9 and 10 show abundant boulders and apparent wind erosion. On the Pioneer Venus 1978 Orbiter mission, the radar mapper experiment will determine surface heights, dielectric constant values and small-scale slope values along the sub-orbital track between 50/sup 0/S and 75/sup 0/N. This experiment will also estimate the global shape and provide coarse radar images (40-80 km identification resolution) of part of the surface. Gravity data will be obtained by radio tracking. Maps combining radar altimetry with spacecraft and ground-based images will be made. A fluxgate magnetometer will measure the magnetic fields around Venus. The radar and gravity data will provide clues to the level of crustal differentiation and tectonic activity. The magnetometer will determine the field variations accurately. Data from the combined experiments may constrain the dynamo mechanism; if so, a deeper understanding of both Venus and Earth will be gained.

  8. Quantum critical environment assisted quantum magnetometer

    Science.gov (United States)

    Jaseem, Noufal; Omkar, S.; Shaji, Anil

    2018-04-01

    A central qubit coupled to an Ising ring of N qubits, operating close to a critical point is investigated as a potential precision quantum magnetometer for estimating an applied transverse magnetic field. We compute the quantum Fisher information for the central, probe qubit with the Ising chain initialized in its ground state or in a thermal state. The non-unitary evolution of the central qubit due to its interaction with the surrounding Ising ring enhances the accuracy of the magnetic field measurement. Near the critical point of the ring, Heisenberg-like scaling of the precision in estimating the magnetic field is obtained when the ring is initialized in its ground state. However, for finite temperatures, the Heisenberg scaling is limited to lower ranges of N values.

  9. Comparison of Vertical Drifts of ISR and Magnetometer Data Measurements at the Magnetic Equator

    Science.gov (United States)

    Condor P, P. J.

    2014-12-01

    We compare vertical drifts measured with the Jicamarca incoherent scatter radar (ISR) and drifts estimated from magnetometer data applying a Neural Network data processing technique. For the application of the Neural Network (NN) method, we use the magnitude of the horizontal (H) component of the magnetic field measured with magnetometers at Jicamarca and Piura (Peru). The data was collected between the years 2002 and 2013. In training the NN we use the difference between the magnitudes of the horizontal components (dH) measured at JRO (placed at the magnetic equator) and Piura (displaced 5° away). Additional parameters used are F10.7 and Ap indexes. The estimates obtained with the NN procedure are very good. We have an RMS error of 3.7 m/s using dH as an input of the NN while the error is 3.9 m/s when we use the component H of JRO as an input. The results are validated using the set of vertical drifts observations collected with the Jicamarca incoherent scatter radar. The estimated drifts can be accessed using the following website: http://jro.igp.gob.pe/driftnn. In the poster, we show the comparison of vertical drifts from 2002 to 2013 where we discuss the agreement between magnetometer and ISR data.

  10. Loop-locked coherent population trapping magnetometer based on a fiber electro-optic modulator.

    Science.gov (United States)

    Hu, Yong; Feng, Y Y; Xu, Chi; Xue, H B; Sun, Li

    2014-04-01

    We have set up a coherent population trapping (CPT)-based magnetometer prototype with the D1 line of ⁸⁷Rb atoms. The dichromatic light field is derived from a fiber electro-optic modulator (FEOM) connected to an external cavity laser diode. A CPT resonance signal with a 516 Hz linewidth is observed. By feeding back the derivative of the resonance curve to the FEOM with a proportional integral controller, of which the voltage output is directly converted to the measured magnetic field intensity, the resonance peak is locked to the environmental magnetic field. The measurement data we have achieved are well matched with the data measured by a commercial fluxgate magnetometer within 2 nT, and the sensitivity is better than 8 pT/√Hz in a parallel B field.

  11. New type of fluxgate magnetometer for the heart’s magnetic fields detection

    Directory of Open Access Journals (Sweden)

    Rybalko Ruslan

    2015-09-01

    Full Text Available The application area of fluxgate sensors is limited by their sensitivity. Medical researches create high demand on the magnetometers with the characteristics of high accuracy and sensibility for measuring weak magnetic fields produced by the human body, such as the heart‘s magnetic field. Due to the insufficient sensitivity of fluxgate sensors, superconducting magnetometers (SQUID take the dominant position for the cardiomagnetic measurements. They have to be cooled by liquefied gases and it leads to high service costs. Therefore an idea of creating a high sensitive sensor based on fluxgate principles and known methods of measurement is attractive and up to date. This paper is dedicated to the modified flux-gate sensors based on Racetrack technology with a new approach of signal demodulation. The improved fluxgate sensor system provides detection of the heart‘s magnetic field without additional expenditures for use.

  12. Miniaturized digital fluxgate magnetometer for small spacecraft applications

    International Nuclear Information System (INIS)

    Forslund, Åke; Ivchenko, Nickolay; Olsson, Göran; Edberg, Terry; Belyayev, Serhiy; Marusenkov, Andriy

    2008-01-01

    A novel design of an Earth field digital fluxgate magnetometer is presented, the small magnetometer in low-mass experiment (SMILE). The combination of a number of new techniques results in significant miniaturization of both sensor and electronics. The design uses a sensor with volume compensation, combining three dual rod cores in a Macor® cube with the side dimension of 20 mm. Use of volume compensation provides high geometrical stability of the axes and improved performance compared to component compensated sensors. The sensor is operated at an excitation frequency of 8 kHz. Most of the instrument functionality is combined in a digital signal processing core, implemented in a field programmable gate array (FPGA). The pick-up signal is digitized after amplification and filtering, and values of compensation currents for each of the axes are determined by a digital correlation algorithm, equivalent to a matched filter, and are fed to a hybrid pulse-width modulation/delta-sigma digital-to-analogue converter driving the currents through the compensation coils. Using digital design makes the instrument very flexible, reduces power consumption and opens possibilities for the customization of the operation modes. The current implementation of the design is based on commercial off-the-shelf components. A calibration of the SMILE instrument was carried out at the Nurmijärvi Geophysical Observatory, showing high linearity (within 6 nT on the whole ±50 µT scale), good orthogonality (22 arcmin) and very good temperature stability of the axes

  13. Diurnal and Seasonal Variations in Mid-Latitude Geomagnetic Field During International Quiet Days: BOH Magnetometer

    Directory of Open Access Journals (Sweden)

    Junga Hwang

    2012-12-01

    Full Text Available Korea Astronomy and Space Science Institute researchers have installed and operated magnetometers at Bohyunsan Observatory to measure the Earth's magnetic field variations in South Korea. In 2007, we installed a fluxgate magnetometer (RFP-523C to measure H, D, and Z components of the geomagnetic field. In addition, in 2009, we installed a Overhauser proton sensor to measure the absolute total magnetic field F and a three-axis magneto-impedance sensor for spectrum analysis. Currently three types of magnetometer data have been accumulated. In this paper, we use the H, D, Z components of fluxgate magnetometer data to investigate the characteristics of mid-latitude geomagnetic field variation. To remove the temporary changes in Earth’s geomagnetic filed by space weather, we use the international quiet days’ data only. In other words, we performed a superposed epoch analysis using five days per each month during 2008-2011. We find that daily variations of H, D, and Z shows similar tendency compared to previous results using all days. That is, H, D, Z all three components’ quiet intervals terminate near the sunrise and shows maximum 2-3 hours after the culmination and the quiet interval start from near the sunset. Seasonal variations show similar dependences to the Sun. As it becomes hot season, the geomagnetic field variation’s amplitude becomes large and the quiet interval becomes shortened. It is well-known that these variations are effects of Sq current system in the Earth’s atmosphere. We confirm that the typical mid-latitude geomagnetic field variations due to the Sq current system by excluding all possible association with the space weather.

  14. Magnetic shield effect simulation of superconducting film shield covering directly coupled HTS dc-SQUID magnetometer

    International Nuclear Information System (INIS)

    Terauchi, N.; Noguchi, S.; Igarashi, H.

    2011-01-01

    A superconducting film shield over a SQUID ring improves the robustness of the SQUID with respect to magnetic noise. Supercurrent in the SQUID magnetometer and the superconducting film shield were simulated. The superconducting film shield reduces the influence of the external magnetic field on the SQUID ring. An HTS SQUID is a high sensitive magnetic sensor. In recent years, the HTS SQUID is widely used in various applications. In some applications, high robustness with respect to magnetic noise is required to realize stable operation at outside of a magnetic shielding room. The target of this paper is a directly coupled HTS dc-SQUID magnetometer. To enhance the robustness of the SQUID magnetometer, use of a superconducting thin film shield has been proposed. The magnetic field directly penetrating the SQUID ring causes the change of the critical current of Josephson junction, and then the SQUID magnetometer transitions into inoperative state. In order to confirm the magnetic shield effect of the superconducting film shield, electromagnetic field simulation with 3D edge finite element method was performed. To simulate the high temperature superconductor, E-J characteristics and c-axis anisotropy are considered. To evaluate the effect of the superconducting film shield, an external magnetic field which is supposed to be a magnetic noise is applied. From the simulation results, the time transition of the magnetic flux penetrating the SQUID ring is investigated and the effect of the superconducting film shield is confirmed. The amplitude of the magnetic flux penetrating the SQUID ring can be reduced to about one-sixth since the superconducting film shield prevents the magnetic noise from directly penetrating the SQUID ring.

  15. The MAGIC of CINEMA: first in-flight science results from a miniaturised anisotropic magnetoresistive magnetometer

    Directory of Open Access Journals (Sweden)

    M. O. Archer

    2015-06-01

    Full Text Available We present the first in-flight results from a novel miniaturised anisotropic magnetoresistive space magnetometer, MAGIC (MAGnetometer from Imperial College, aboard the first CINEMA (CubeSat for Ions, Neutrals, Electrons and MAgnetic fields spacecraft in low Earth orbit. An attitude-independent calibration technique is detailed using the International Geomagnetic Reference Field (IGRF, which is temperature dependent in the case of the outboard sensor. We show that the sensors accurately measure the expected absolute field to within 2% in attitude mode and 1% in science mode. Using a simple method we are able to estimate the spacecraft's attitude using the magnetometer only, thus characterising CINEMA's spin, precession and nutation. Finally, we show that the outboard sensor is capable of detecting transient physical signals with amplitudes of ~ 20–60 nT. These include field-aligned currents at the auroral oval, qualitatively similar to previous observations, which agree in location with measurements from the DMSP (Defense Meteorological Satellite Program and POES (Polar-orbiting Operational Environmental Satellites spacecraft. Thus, we demonstrate and discuss the potential science capabilities of the MAGIC instrument onboard a CubeSat platform.

  16. A simple vibrating sample magnetometer for macroscopic samples

    Science.gov (United States)

    Lopez-Dominguez, V.; Quesada, A.; Guzmán-Mínguez, J. C.; Moreno, L.; Lere, M.; Spottorno, J.; Giacomone, F.; Fernández, J. F.; Hernando, A.; García, M. A.

    2018-03-01

    We here present a simple model of a vibrating sample magnetometer (VSM). The system allows recording magnetization curves at room temperature with a resolution of the order of 0.01 emu and is appropriated for macroscopic samples. The setup can be mounted with different configurations depending on the requirements of the sample to be measured (mass, saturation magnetization, saturation field, etc.). We also include here examples of curves obtained with our setup and comparison curves measured with a standard commercial VSM that confirms the reliability of our device.

  17. In-flight calibration of the spin axis offset of a fluxgate magnetometer with an electron drift instrument

    Science.gov (United States)

    Leinweber, H. K.; Russell, C. T.; Torkar, K.

    2012-10-01

    We show that the spin axis offset of a fluxgate magnetometer can be calibrated with an electron drift instrument (EDI) and that the required input time interval is relatively short. For missions such as Cluster or the upcoming Magnetospheric Multiscale (MMS) mission the spin axis offset of a fluxgate magnetometer could be determined on an orbital basis. An improvement of existing methods for finding spin axis offsets via comparison of accurate measurements of the field magnitude is presented, that additionally matches the gains of the two instruments that are being compared. The technique has been applied to EDI data from the Cluster Active Archive and fluxgate magnetometer data processed with calibration files also from the Cluster Active Archive. The method could prove to be valuable for the MMS mission because the four MMS spacecraft will only be inside the interplanetary field (where spin axis offsets can be calculated from Alfvénic fluctuations) for short periods of time and during unusual solar wind conditions.

  18. In-flight calibration of the spin axis offset of a fluxgate magnetometer with an electron drift instrument

    International Nuclear Information System (INIS)

    Leinweber, H K; Russell, C T; Torkar, K

    2012-01-01

    We show that the spin axis offset of a fluxgate magnetometer can be calibrated with an electron drift instrument (EDI) and that the required input time interval is relatively short. For missions such as Cluster or the upcoming Magnetospheric Multiscale (MMS) mission the spin axis offset of a fluxgate magnetometer could be determined on an orbital basis. An improvement of existing methods for finding spin axis offsets via comparison of accurate measurements of the field magnitude is presented, that additionally matches the gains of the two instruments that are being compared. The technique has been applied to EDI data from the Cluster Active Archive and fluxgate magnetometer data processed with calibration files also from the Cluster Active Archive. The method could prove to be valuable for the MMS mission because the four MMS spacecraft will only be inside the interplanetary field (where spin axis offsets can be calculated from Alfvénic fluctuations) for short periods of time and during unusual solar wind conditions. (paper)

  19. A nitrogen triple-point thermal storage unit for cooling a SQUID magnetometer

    NARCIS (Netherlands)

    Rijpma, A.P.; Meenderink, D.J.; Reincke, H.A.; Venhorst, G.C.F.; Holland, H.J.; Brake, ter H.J.M.

    2005-01-01

    In order to achieve turnkey operation, the use is planned of cryocoolers to cool a SQUID magnetometer system. To minimize the magnetical and mech. interference from the coolers, they are switched off during the actual measurements. Consequently, a thermal storage unit (TSU) is required with

  20. Combined spacecraft orbit and attitude control through extended Kalman filtering of magnetometer, gyro, and GPS measurements

    Directory of Open Access Journals (Sweden)

    Tamer Mekky Ahmed Habib

    2014-06-01

    Full Text Available The main goal of this research is to establish spacecraft orbit and attitude control algorithms based on extended Kalman filter which provides estimates of spacecraft orbital and attitude states. The control and estimation algorithms must be capable of dealing with the spacecraft conditions during the detumbling and attitude acquisition modes of operation. These conditions are characterized by nonlinearities represented by large initial attitude angles, large initial angular velocities, large initial attitude estimation error, and large initial position estimation error. All of the developed estimation and control algorithms are suitable for application to the next Egyptian scientific satellite, EGYPTSAT-2. The parameters of the case-study spacecraft are similar but not identical to the former Egyptian satellite EGYPTSAT-1. This is done because the parameters of EGYPTSAT-2 satellite have not been consolidated yet. The sensors utilized are gyro, magnetometer, and GPS. Gyro and magnetometer are utilized to provide measurements for the estimates of spacecraft attitude state vector where as magnetometer and GPS are utilized to provide measurements for the estimates of spacecraft orbital state vector.

  1. Development of fluxgate magnetometers and applications to the space science missions

    Science.gov (United States)

    Matsuoka, A.; Shinohara, M.; Tanaka, Y.-M.; Fujimoto, A.; Iguchi, K.

    2013-11-01

    Magnetic field is one of the essential physical parameters to study the space physics and evolution of the solar system. There are several methods to measure the magnetic field in the space by spacecraft and rockets. Fluxgate magnetometer has been most generally used out of them because it measures the vector field accurately and does not need much weight and power budgets. When we try more difficult missions such as multi-satellite observation, landing on the celestial body and exploration in the area of severe environment, we have to modify the magnetometer or develop new techniques to make the instrument adequate for those projects. For example, we developed a 20-bit delta-sigma analogue-to-digital converter for MGF-I on the BepiColombo MMO satellite, to achieve the wide-range (±2000 nT) measurement with good resolution in the high radiation environment. For further future missions, we have examined the digitalizing of the circuit, which has much potential to drastically reduce the instrument weight, power consumption and performance dependence on the temperature.

  2. A nitrogen triple-point thermal storage unit for cooling a SQUID magnetometer

    NARCIS (Netherlands)

    Rijpma, A.P.; Meenderink, D.J.; Reincke, H.A.; Venhorst, G.C.F.; Venhorst, G.C.F.; Holland, Herman J.; ter Brake, Hermanus J.M.

    2005-01-01

    In order to achieve turnkey operation, we plan to use cryocoolers to cool a SQUID magnetometer system. To minimize the magnetical and mechanical interference from the coolers, we intend to switch them off during the actual measurements. Consequently, a thermal storage unit (TSU) is required with

  3. The effect of winding and core support material on the thermal gain dependence of a fluxgate magnetometer sensor

    Science.gov (United States)

    Miles, David M.; Mann, Ian R.; Kale, Andy; Milling, David K.; Narod, Barry B.; Bennest, John R.; Barona, David; Unsworth, Martyn J.

    2017-10-01

    Fluxgate magnetometers are an important tool in geophysics and space physics but are typically sensitive to variations in sensor temperature. Changes in instrumental gain with temperature, thermal gain dependence, are thought to be predominantly due to changes in the geometry of the wire coils that sense the magnetic field and/or provide magnetic feedback. Scientific fluxgate magnetometers typically employ some form of temperature compensation and support and constrain wire sense coils with bobbins constructed from materials such as MACOR machinable ceramic (Corning Inc.) which are selected for their ultra-low thermal deformation rather than for robustness, cost, or ease of manufacturing. We present laboratory results comparing the performance of six geometrically and electrically matched fluxgate sensors in which the material used to support the windings and for the base of the sensor is varied. We use a novel, low-cost thermal calibration procedure based on a controlled sinusoidal magnetic source and quantitative spectral analysis to measure the thermal gain dependence of fluxgate magnetometer sensors at the ppm°C-1 level in a typical magnetically noisy university laboratory environment. We compare the thermal gain dependence of sensors built from MACOR, polyetheretherketone (PEEK) engineering plastic (virgin, 30 % glass filled and 30 % carbon filled), and acetal to examine the trade between the thermal properties of the material, the impact on the thermal gain dependence of the fluxgate, and the cost and ease of manufacture. We find that thermal gain dependence of the sensor varies as one half of the material properties of the bobbin supporting the wire sense coils rather than being directly related as has been historically thought. An experimental sensor constructed from 30 % glass-filled PEEK (21.6 ppm°C-1) had a thermal gain dependence within 5 ppm°C-1 of a traditional sensor constructed from MACOR ceramic (8.1 ppm°C-1). If a modest increase in thermal

  4. A radiation hardened digital fluxgate magnetometer for space applications

    Science.gov (United States)

    Miles, D. M.; Bennest, J. R.; Mann, I. R.; Millling, D. K.

    2013-09-01

    Space-based measurements of Earth's magnetic field are required to understand the plasma processes responsible for energising particles in the Van Allen radiation belts and influencing space weather. This paper describes a prototype fluxgate magnetometer instrument developed for the proposed Canadian Space Agency's (CSA) Outer Radiation Belt Injection, Transport, Acceleration and Loss Satellite (ORBITALS) mission and which has applications in other space and suborbital applications. The magnetometer is designed to survive and operate in the harsh environment of Earth's radiation belts and measure low-frequency magnetic waves, the magnetic signatures of current systems, and the static background magnetic field. The new instrument offers improved science data compared to its predecessors through two key design changes: direct digitisation of the sensor and digital feedback from two cascaded pulse-width modulators combined with analog temperature compensation. These provide an increase in measurement bandwidth up to 450 Hz with the potential to extend to at least 1500 Hz. The instrument can resolve 8 pT on a 65 000 nT field with a magnetic noise of less than 10 pT/√Hz at 1 Hz. This performance is comparable with other recent digital fluxgates for space applications, most of which use some form of sigma-delta (ΣΔ) modulation for feedback and omit analog temperature compensation. The prototype instrument was successfully tested and calibrated at the Natural Resources Canada Geomagnetics Laboratory.

  5. IceBridge Scintrex CS-3 Cesium Magnetometer L0 Raw Magnetic Field, Version 1

    Data.gov (United States)

    National Aeronautics and Space Administration — The NASA IceBridge Scintrex CS-3 Cesium Magnetometer L0 Raw Magnetic Field data set contains magnetic field readings and fluxgate values taken over Greenland using...

  6. Multilayer Based Technology to Build RTD Fluxgate Magnetometer

    Directory of Open Access Journals (Sweden)

    B. ANDO

    2006-03-01

    Full Text Available In this paper we discuss the main features of the Residence Times Difference Fluxgate Magnetometer. A low-cost technology, negligible onboard power requirements and the intrinsic digital form of the readout signal are the main advantages of the proposed strategy. Results obtained show the possibility to realise low-cost devices exploiting Printed Circuit Board (PCB technology for applications requiring resolution in the nanotesla range as the ferrous object (or particles detection, being the performance obtained suitable to detect the presence or the transit of ferrous materials via their interaction with the geomagnetic field.

  7. Magnetometer Data in the Classroom as a part of the NASA THEMIS Satellite Mission

    Science.gov (United States)

    Peticolas, L. M.; Bean, J.; Walker, A.

    2011-12-01

    The NASA-funded THEMIS mission was designed to determine the onset time and location of magnetic substorms of Earth's space environment, a prerequisite to understanding space weather. THEMIS is an acronym for Time History of Events and Macroscale Interactions during Substorms. he Geomagnetic Event Observation Network by Students (GEONS) project was the flagship, formal education component of the E/PO program. With the placement of magnetometers in the proximity of rural schools throughout the country, middle and high school teachers along with their students benefited from the opportunity to work with 'real-time' data and participated in hands-on space science activities. Particular attention was paid to placing the magnetometer stations at schools in rural communities whose students were traditionally underserved and underrepresented in the sciences. The project offered to the teachers of these students long-term professional development opportunities that centered around THEMIS-related space science and the magnetometer data. The THEMIS E/PO final evaluation report for the main phase of the THEMIS mission covered the period from 2003-2009, describing the impact of this program such as this program placed magnetometers sites at 13 rural, underserved schools/communities, two-fifths of which are on tribal lands; and provided intensive professional development for 20 teachers from 2004 through 2009. A core group of eight teachers estimated reaching more than 2,720 students with THEMIS-related materials/ideas. 75% of these students are minorities in science. Core teachers provided evidence of the project's positive impact on students' attitudes toward science and their choices for courses that position them for STEM-related careers. Core teachers reported sharing THEMIS-related materials/ideas with 275 colleagues. The NewsHour with Jim Lehrer featured the Petersburg, Alaska site potentially reaching more than 5 million viewers in two airings, according to Nielsen

  8. Two-channel recoder for magnetometer with energy-independent mass memory device

    International Nuclear Information System (INIS)

    Korzinin, V.N.; Selivanov, A.M.

    1993-01-01

    The paper describes a two-channel digit-to-analog recorder designed for converting the sequence of pulses from proton magnetometer (MMH-203) outlet; the device enables processing of the pulses and their recording in RAM and on the tape of the analog recorder. The availability of nonvolotile RAM allows to transmit digit information to a computer (BK-0010) for its further processing

  9. Basic technical parameters of magnetometers with ferromagnetic transducers and a method to define them

    International Nuclear Information System (INIS)

    Nagiello, Z.

    1980-01-01

    The basic technical parameters of magnetometers with ferromagnetic transducers and measuring methods to define these parameters have been discussed. Special attention was paid to factors which essentially affect the inaccuracy of these measuring instruments. (author)

  10. UNMANNED AIRCRAFT SYSTEMS FOR RAPID NEAR SURFACE GEOPHYSICAL MEASUREMENTS

    Directory of Open Access Journals (Sweden)

    J. B. Stoll

    2013-08-01

    Full Text Available This paper looks at some of the unmanned aircraft systems (UAS options and deals with a magnetometer sensor system which might be of interest in conducting rapid near surface geophysical measurements. Few of the traditional airborne geophysical sensors are now capable of being miniaturized to sizes and payload within mini UAS limits (e.g. airborne magnetics, gamma ray spectrometer. Here the deployment of a fluxgate magnetometer mounted on an UAS is presented demonstrating its capability of detecting metallic materials that are buried in the soil. The effectiveness in finding ferrous objects (e.g. UXO, landslides is demonstrated in two case studies.

  11. General theory of detection of signal induced in vibrating magnetometer

    International Nuclear Information System (INIS)

    Pacyna, A.W.

    1980-01-01

    Assuming the point dipole approximation only and making use of the vectorial notation, signal (EMF) induced in a single-turn pick-up coil of the vibrating magnetometer are calculated for the case of any orientation of the coil, of vibration axis and of the magnetic moment of the sample. On the basis of formula obtained, three types of measurement geometries have been distinquished and for these the qualitative analysis is made. (author)

  12. Effects of diffusion and surface interactions on the line shape of electron paramagnetic resonances in the presence of a magnetic field gradient

    International Nuclear Information System (INIS)

    Schaden, M.; Zhao, K. F.; Wu, Z.

    2007-01-01

    In an evanescent wave magnetometer the Zeeman polarization is probed at micrometer to submicrometer distances from the cell surface. The electron paramagnetic resonance lines of an evanescent wave magnetometer in the presence of a magnetic field gradient exhibit edge enhancement seen previously in nuclear magnetic resonance lines. We present a theoretical model that describes quantitatively the shape of the magnetic resonance lines of an evanescent wave magnetometer under a wide range of experimental conditions. It accounts for diffusion broadening in the presence of a magnetic field gradient as well as interactions of spin polarized Rb atoms with the coated Pyrex glass surfaces. Depending on the field gradient, cell thickness, and buffer gas pressure, the resonance line may have the form of a single asymmetric peak or two peaks localized near the front and back surfaces in frequency space. The double-peaked response depends on average characteristics of the surface interactions. Its shape is sensitive to the dwell time, relaxation probability, and average phase shift of adsorbed spin polarized Rb atoms

  13. The effect of winding and core support material on the thermal gain dependence of a fluxgate magnetometer sensor

    Directory of Open Access Journals (Sweden)

    D. M. Miles

    2017-10-01

    Full Text Available Fluxgate magnetometers are an important tool in geophysics and space physics but are typically sensitive to variations in sensor temperature. Changes in instrumental gain with temperature, thermal gain dependence, are thought to be predominantly due to changes in the geometry of the wire coils that sense the magnetic field and/or provide magnetic feedback. Scientific fluxgate magnetometers typically employ some form of temperature compensation and support and constrain wire sense coils with bobbins constructed from materials such as MACOR machinable ceramic (Corning Inc. which are selected for their ultra-low thermal deformation rather than for robustness, cost, or ease of manufacturing. We present laboratory results comparing the performance of six geometrically and electrically matched fluxgate sensors in which the material used to support the windings and for the base of the sensor is varied. We use a novel, low-cost thermal calibration procedure based on a controlled sinusoidal magnetic source and quantitative spectral analysis to measure the thermal gain dependence of fluxgate magnetometer sensors at the ppm°C−1 level in a typical magnetically noisy university laboratory environment. We compare the thermal gain dependence of sensors built from MACOR, polyetheretherketone (PEEK engineering plastic (virgin, 30 % glass filled and 30 % carbon filled, and acetal to examine the trade between the thermal properties of the material, the impact on the thermal gain dependence of the fluxgate, and the cost and ease of manufacture. We find that thermal gain dependence of the sensor varies as one half of the material properties of the bobbin supporting the wire sense coils rather than being directly related as has been historically thought. An experimental sensor constructed from 30 % glass-filled PEEK (21.6 ppm°C−1 had a thermal gain dependence within 5 ppm°C−1 of a traditional sensor constructed from MACOR ceramic (8.1

  14. On determining fluxgate magnetometer spin axis offsets from mirror mode observations

    Science.gov (United States)

    Plaschke, Ferdinand; Narita, Yasuhito

    2016-09-01

    In-flight calibration of fluxgate magnetometers that are mounted on spacecraft involves finding their outputs in vanishing ambient fields, the so-called magnetometer offsets. If the spacecraft is spin-stabilized, then the spin plane components of these offsets can be relatively easily determined, as they modify the spin tone content in the de-spun magnetic field data. The spin axis offset, however, is more difficult to determine. Therefore, usually Alfvénic fluctuations in the solar wind are used. We propose a novel method to determine the spin axis offset: the mirror mode method. The method is based on the assumption that mirror mode fluctuations are nearly compressible such that the maximum variance direction is aligned to the mean magnetic field. Mirror mode fluctuations are typically found in the Earth's magnetosheath region. We introduce the method and provide a first estimate of its accuracy based on magnetosheath observations by the THEMIS-C spacecraft. We find that 20 h of magnetosheath measurements may already be sufficient to obtain high-accuracy spin axis offsets with uncertainties on the order of a few tenths of a nanotesla, if offset stability can be assumed.

  15. On determining fluxgate magnetometer spin axis offsets from mirror mode observations

    Directory of Open Access Journals (Sweden)

    F. Plaschke

    2016-09-01

    Full Text Available In-flight calibration of fluxgate magnetometers that are mounted on spacecraft involves finding their outputs in vanishing ambient fields, the so-called magnetometer offsets. If the spacecraft is spin-stabilized, then the spin plane components of these offsets can be relatively easily determined, as they modify the spin tone content in the de-spun magnetic field data. The spin axis offset, however, is more difficult to determine. Therefore, usually Alfvénic fluctuations in the solar wind are used. We propose a novel method to determine the spin axis offset: the mirror mode method. The method is based on the assumption that mirror mode fluctuations are nearly compressible such that the maximum variance direction is aligned to the mean magnetic field. Mirror mode fluctuations are typically found in the Earth's magnetosheath region. We introduce the method and provide a first estimate of its accuracy based on magnetosheath observations by the THEMIS-C spacecraft. We find that 20 h of magnetosheath measurements may already be sufficient to obtain high-accuracy spin axis offsets with uncertainties on the order of a few tenths of a nanotesla, if offset stability can be assumed.

  16. Study on modulation amplitude stabilization method for PEM based on FPGA in atomic magnetometer

    Science.gov (United States)

    Wang, Qinghua; Quan, Wei; Duan, Lihong

    2017-10-01

    Atomic magnetometer which uses atoms as sensitive elements have ultra-high precision and has wide applications in scientific researches. The photoelastic modulation method based on photoelastic modulator (PEM) is used in the atomic magnetometer to detect the small optical rotation angle of a linearly polarized light. However, the modulation amplitude of the PEM will drift due to the environmental factors, which reduces the precision and long-term stability of the atomic magnetometer. Consequently, stabilizing the PEM's modulation amplitude is essential to precision measurement. In this paper, a modulation amplitude stabilization method for PEM based on Field Programmable Gate Array (FPGA) is proposed. The designed control system contains an optical setup and an electrical part. The optical setup is used to measure the PEM's modulation amplitude. The FPGA chip, with the PID control algorithm implemented in it, is used as the electrical part's micro controller. The closed loop control method based on the photoelastic modulation detection system can directly measure the PEM's modulation amplitude in real time, without increasing the additional optical devices. In addition, the operating speed of the modulation amplitude stabilization control system can be greatly improved because of the FPGA's parallel computing feature, and the PID control algorithm ensures flexibility to meet different needs of the PEM's modulation amplitude set values. The Modelsim simulation results show the correctness of the PID control algorithm, and the long-term stability of the PEM's modulation amplitude reaches 0.35% in a 3-hour continuous measurement.

  17. 10. The surface and interior of venus

    Science.gov (United States)

    Masursky, H.; Kaula, W.M.; McGill, G.E.; Pettengill, G.H.; Phillips, R.J.; Russell, C.T.; Schubert, G.; Shapiro, I.I.

    1977-01-01

    Present ideas about the surface and interior of Venus are based on data obtained from (1) Earth-based radio and radar: temperature, rotation, shape, and topography; (2) fly-by and orbiting spacecraft: gravity and magnetic fields; and (3) landers: winds, local structure, gamma radiation. Surface features, including large basins, crater-like depressions, and a linear valley, have been recognized from recent ground-based radar images. Pictures of the surface acquired by the USSR's Venera 9 and 10 show abundant boulders and apparent wind erosion. On the Pioneer Venus 1978 Orbiter mission, the radar mapper experiment will determine surface heights, dielectric constant values and small-scale slope values along the sub-orbital track between 50??S and 75??N. This experiment will also estimate the global shape and provide coarse radar images (40-80 km identification resolution) of part of the surface. Gravity data will be obtained by radio tracking. Maps combining radar altimetry with spacecraft and ground-based images will be made. A fluxgate magnetometer will measure the magnetic fields around Venus. The radar and gravity data will provide clues to the level of crustal differentiation and tectonic activity. The magnetometer will determine the field variations accurately. Data from the combined experiments may constrain the dynamo mechanism; if so, a deeper understanding of both Venus and Earth will be gained. ?? 1977 D. Reidel Publishing Company.

  18. The Global Network of Optical Magnetometers for Exotic physics (GNOME): A novel scheme to search for physics beyond the Standard Model

    International Nuclear Information System (INIS)

    Pustelny, Szymon; Jackson Kimball, Derek F.; Pankow, Chris; Ledbetter, Micah P.; Wlodarczyk, Przemyslaw; Wcislo, Piotr; Pospelov, Maxim; Smith, Joshua R.; Read, Jocelyn; Gawlik, Wojciech; Budker, Dmitry

    2013-01-01

    A novel experimental scheme enabling the investigation of transient exotic spin couplings is discussed. The scheme is based on synchronous measurements of optical-magnetometer signals from several devices operating in magnetically shielded environments in distant locations (>or similar 100 km). Although signatures of such exotic couplings may be present in the signal from a single magnetometer, it would be challenging to distinguish them from noise. By analyzing the correlation between signals from multiple, geographically separated magnetometers, it is not only possible to identify the exotic transient but also to investigate its nature. The ability of the network to probe presently unconstrained physics beyond the Standard Model is examined by considering the spin coupling to stable topological defects (e.g., domain walls) of axion-like fields. In the spirit of this research, a brief (∝2 hours) demonstration experiment involving two magnetometers located in Krakow and Berkeley (∝9000 km separation) is presented and discussion of the data-analysis approaches that may allow identification of transient signals is provided. The prospects of the network are outlined in the last part of the paper. (copyright 2013 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  19. Three axis vector atomic magnetometer utilizing polarimetric technique

    Energy Technology Data Exchange (ETDEWEB)

    Pradhan, Swarupananda, E-mail: spradhan@barc.gov.in, E-mail: pradhans75@gmail.com [Laser and Plasma Technology Division, Bhabha Atomic Research Centre, Mumbai 400085, India and Homi Bhabha National Institute, Department of Atomic Energy, Mumbai 400094 (India)

    2016-09-15

    The three axis vector magnetic field measurement based on the interaction of a single elliptically polarized light beam with an atomic system is described. The magnetic field direction dependent atomic responses are extracted by the polarimetric detection in combination with laser frequency modulation and magnetic field modulation techniques. The magnetometer geometry offers additional critical requirements like compact size and large dynamic range for space application. Further, the three axis magnetic field is measured using only the reflected signal (one polarization component) from the polarimeter and thus can be easily expanded to make spatial array of detectors and/or high sensitivity field gradient measurement as required for biomedical application.

  20. ATS-6 - UCLA fluxgate magnetometer

    Science.gov (United States)

    Mcpherron, R. L.; Coleman, P. J., Jr.; Snare, R. C.

    1975-01-01

    A summary of the design of the University of California at Los Angeles' fluxgate magnetometer is presented. Instrument noise in the bandwidth 0.001 to 1.0 Hz is of order 85 m gamma. The DC field of the spacecraft transverse to the earth-pointing axis is 1.0 + or - 21 gamma in the X direction and -2.4 + or - 1.3 gamma in the Y direction. The spacecraft field parallel to this axis is less than 5 gamma. The small spacecraft field has made possible studies of the macroscopic field not previously possible at synchronous orbit. At the 96 W longitude of Applications Technology Satellite-6 (ATS-6), the earth's field is typically inclined 30 deg to the dipole axis at local noon. Most perturbations of the field are due to substorms. These consist of a rotation in the meridian to a more radial field followed by a subsequent rotation back. The rotation back is normally accompanied by transient variations in the azimuthal field. The exact timing of these perturbations is a function of satellite location and the details of substorm development.

  1. A wide-frequency range AC magnetometer to measure the specific absorption rate in nanoparticles for magnetic hyperthermia

    International Nuclear Information System (INIS)

    Garaio, E.; Collantes, J.M.; Garcia, J.A.; Plazaola, F.; Mornet, S.; Couillaud, F.; Sandre, O.

    2014-01-01

    Measurement of specific absorption rate (SAR) of magnetic nanoparticles is crucial to assert their potential for magnetic hyperthermia. To perform this task, calorimetric methods are widely used. However, those methods are not very accurate and are difficult to standardize. In this paper, we present AC magnetometry results performed with a lab-made magnetometer that is able to obtain dynamic hysteresis-loops in the AC magnetic field frequency range from 50 kHz to 1 MHz and intensities up to 24 kA m −1 . In this work, SAR values of maghemite nanoparticles dispersed in water are measured by AC magnetometry. The so-obtained values are compared with the SAR measured by calorimetric methods. Both measurements, by calorimetry and magnetometry, are in good agreement. Therefore, the presented AC magnetometer is a suitable way to obtain SAR values of magnetic nanoparticles. - Highlights: • We propose AC magnetometry as a method to measure the specific absorption rate (SAR) of magnetic nanoparticles suitable for magnetic hyperthermia therapy. • We have built a lab-made AC magnetometer, which is able to measure magnetic dynamic hysteresis-loops of nanoparticle dispersions. • The device works with AC magnetic field intensities up to 24 kA m −1 in a frequency range from 75 kHz to 1 MHz. • The SAR values of maghemite nanoparticles around 12 nm in magnetic diameter dispersed in water are measured by the lab-made magnetometer and different calorimetric methods. • Although all methods are in good agreement, several factors (probe location, thermal inertia, losses, etc.) make calorimetric method less accurate than AC magnetometry

  2. CalMagNet – an array of search coil magnetometers monitoring ultra low frequency activity in California

    Directory of Open Access Journals (Sweden)

    C. Dunson

    2008-04-01

    Full Text Available The California Magnetometer Network (CalMagNet consists of sixty-eight triaxial search-coil magnetometer systems measuring Ultra Low Frequency (ULF, 0.001–16 Hz, magnetic field fluctuations in California. CalMagNet provides data for comprehensive multi-point measurements of specific events in the Pc 1–Pc 5 range at mid-latitudes as well as a systematic, long-term study of ULF signals in active fault regions in California. Typical events include geomagnetic micropulsations and spectral resonant structures associated with the ionospheric Alfvén resonator. This paper provides a technical overview of the CalMagNet sensors and data processing systems. The network is composed of ten reference stations and fifty-eight local monitoring stations. The primary instruments at each site are three orthogonal induction coil magnetometers. A geophone monitors local site vibration. The systems are designed for future sensor expansion and include resources for monitoring four additional channels. Data is currently sampled at 32 samples per second with a 24-bit converter and time tagged with a GPS-based timing system. Several examples of representative magnetic fluctuations and signals as measured by the array are given.

  3. IceBridge Scintrex CS-3 Cesium Magnetometer L1B Geolocated Magnetic Anomalies, Version 1

    Data.gov (United States)

    National Aeronautics and Space Administration — The NASA IceBridge Scintrex CS-3 Cesium Magnetometer L1B Geolocated Magnetic Anomalies (IMCS31B) data set contains magnetic field readings taken over Greenland using...

  4. A Near-real-time Data Transport System for Selected Stations in the Magnetometer Array for Cusp and Cleft Studies (MACCS)

    Science.gov (United States)

    Engebretson, M. J.; Valentic, T. A.; Stehle, R. H.; Hughes, W. J.

    2004-05-01

    The Magnetometer Array for Cusp and Cleft Studies (MACCS) is a two-dimensional array of eight fluxgate magnetometers that was established in 1992-1993 in the Eastern Canadian Arctic from 75° to over 80° MLAT to study electrodynamic interactions between the solar wind and Earth's magnetosphere and high-latitude ionosphere. A ninth site in Nain, Labrador, extends coverage down to 66° between existing Canadian and Greenland stations. Originally designed as part of NSF's GEM (Geospace Environment Modeling) Program, MACCS has contributed to the study of transients and waves at the magnetospheric boundary and in the near-cusp region as well as to large, cooperative, studies of ionospheric convection and substorm processes. Because of the limitations of existing telephone lines to each site, it has not been possible to economically access MACCS data promptly; instead, each month's collected data is recorded and mailed to the U.S. for processing and eventual posting on a publicly-accessible web site, http://space.augsburg.edu/space. As part of its recently renewed funding, NSF has supported the development of a near-real-time data transport system using the Iridium satellite network, which will be implemented at two MACCS sites in summer 2004. At the core of the new MACCS communications system is the Data Transport Network, software developed with NSF-ITR funding to automate the transfer of scientific data from remote field stations over unreliable, bandwidth-constrained network connections. The system utilizes a store-and-forward architecture based on sending data files as attachments to Usenet messages. This scheme not only isolates the instruments from network outages, but also provides a consistent framework for organizing and accessing multiple data feeds. Client programs are able to subscribe to data feeds to perform tasks such as system health monitoring, data processing, web page updates and e-mail alerts. The MACCS sites will employ the Data Transport Network

  5. Research on Intelligent Control System of DC SQUID Magnetometer Parameters for Multi-channel System

    Science.gov (United States)

    Chen, Hua; Yang, Kang; Lu, Li; Kong, Xiangyan; Wang, Hai; Wu, Jun; Wang, Yongliang

    2018-03-01

    In a multi-channel SQUID measurement system, adjusting device parameters to optimal condition for all channels is time-consuming. In this paper, an intelligent control system is presented to determine the optimal working point of devices which is automatic and more efficient comparing to the manual one. An optimal working point searching algorithm is introduced as the core component of the control system. In this algorithm, the bias voltage V_bias is step scanned to obtain the maximal value of the peak-to-peak current value I_pp of the SQUID magnetometer modulation curve. We choose this point as the optimal one. Using the above control system, more than 30 weakly damped SQUID magnetometers with area of 5 × 5 mm^2 or 10 × 10 mm^2 are adjusted and a 36-channel magnetocardiography system perfectly worked in a magnetically shielded room. The average white flux noise is 15 μΦ_0/Hz^{1/2}.

  6. Feasibility study of a sup 3 He-magnetometer for neutron electric dipole moment experiments

    CERN Document Server

    Borisov, Y; Leduc, M; Lobashev, V; Otten, E W; Sobolev, Y

    2000-01-01

    We report on a sup 3 He-magnetometer capable of detecting tiny magnetic field fluctuations of less than 10 sup - sup 1 sup 4 T in experiments for measuring the electric dipole moment (EDM) of the neutron. It is based on the Ramsey technique of separated oscillating fields and uses nuclear spin-polarized sup 3 He gas which is stored in two vessels of V approx =10 l in a sandwich-type arrangement around the storage bottle for ultra-cold neutrons (UCN). The gas is polarized by means of optical pumping in a separate, small discharge cell at pressures around 0.5 mbar and is then expanded into the actual magnetometer volume. To detect the polarization of sup 3 He gas at the end of the storage cycle the gas is pumped out by means of an oil-diffusion pump and compressed again into the discharge cell where optical detection of nuclear polarization is used.

  7. Setup and taking into operation of a highly sensitive {sup 3}He magnetometer for a future experiment for the determination of an electric dipole moment of the free neutron; Aufbau und Inbetriebnahme eines hochsensitiven {sup 3}He-Magnetometers fuer ein zukuenftiges Experiment zur Bestimmung eines elektrischen Dipolmoments des freien Neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Kraft, Andreas

    2012-12-20

    The measurement of the electric dipole moment of the free neutron is directly linked to the question on the accurate determination of the magnetic field conditions inside the nEDM spectrometer. Using in-situ the spin-precession of polarized {sup 3}He, monitored by optically pumped Cs-magnetometers a sensitivity on the femto-tesla-scale can be obtained. At the institute of physics of the University Mainz a {sup 3}He/Cs-test facility was built to investigate the readout of {sup 3}He-spin-precession with a lamp-pumped Cs-magnetometer. Additionally, an ultra-compact and transportable polarizer unit was developed and installed in Mainz, which polarizes {sup 3}He gas up to 55 % of polarization before the compressed gas is delivered to two sandwich magnetometer cells inside the EDM chamber. This theses will present some results of the first successful test of the polarizer unit in January 2012. {sup 3}He was polarized in the ultra compact polarizer unit and transferred via guiding fields into a 4 layer mu-metal shield, where the free spin precession was detected with a lamp pumped Cs-magnetometer.

  8. A method for combining search coil and fluxgate magnetometer data to reveal finer structures in reconnection physics

    Science.gov (United States)

    Argall, M. R.; Caide, A.; Chen, L.; Torbert, R. B.

    2012-12-01

    Magnetometers have been used to measure terrestrial and extraterrestrial magnetic fields in space exploration ever since Sputnik 3. Modern space missions, such as Cluster, RBSP, and MMS incorporate both search coil magnetometers (SCMs) and fluxgate magnetometers (FGMs) in their instrument suites: FGMs work well at low frequencies while SCMs perform better at high frequencies. In analyzing the noise floor of these instruments, a cross-over region is apparent around 0.3-1.5Hz. The satellite separation of MMS and average speeds of field convection and plasma flows at the subsolar magnetopause make this a crucial range for the upcoming MMS mission. The method presented here combines the signals from SCM and FGM by taking a weighted average of both in this frequency range in order to draw out key features, such as narrow current sheet structures, that would otherwise not be visible. The technique is applied to burst mode Cluster data for reported magnetopause and magnetotail reconnection events to demonstrate the power of the combined data. This technique is also applied to data from the the EMFISIS instrument on the RBSP mission. The authors acknowledge and thank the FGM and STAFF team for the use of their data from the CLUSTER Active Archive.

  9. A Visual Detection System for Determining Tritium Surface Deposition Employing Phosphor Coated Materials

    International Nuclear Information System (INIS)

    Gentile, C.A.; Skinner, C.H.; Young, K.M.; Zweben, S.J.

    1999-01-01

    A method for visually observing tritium deposition on the surface of the Tokamak Fusion Test Reactor (TFTR) deuterium-tritium (D-T) tiles is being investigated at the Princeton Plasma Physics Laboratory. A green phosphor (P31, zinc sulfide: copper) similar to that used in oscilloscope screens with a wavelength peak of 530 nm was positioned on the surface of a TFTR D-T tile. The approximately 600 gram tile, which contains approximately 1.5 Ci of tritium located on the top approximately 1-50 microns of the surface, was placed in a two liter lexan chamber at Standard Temperature and Pressure (STP). The phosphor plates and phosphor powder were placed on the surface of the tile which resulted in visible light being observed, the consequence of tritium betas interacting with the phosphor. This technique provides a method of visually observing varying concentrations of tritium on the surface of D-T carbon tiles, and may be employed (in a calibrated system) to obtain quantitative data

  10. Performance of a novel SQUID-based superconducting imaging-surface magnetoencephalography system

    Science.gov (United States)

    Kraus, R. H.; Volegov, P.; Maharajh, K.; Espy, M. A.; Matlashov, A. N.; Flynn, E. R.

    2002-03-01

    Performance for a recently completed whole-head magnetoencephalography system using a superconducting imaging surface (SIS) surrounding an array of 150 SQUID magnetometers is reported. The helmet-like SIS is hemispherical in shape with a brim. Conceptually, the SIS images nearby sources onto the SQUIDs while shielding sensors from distant “noise” sources. A finite element method (FEM) description using the as-built geometry was developed to describe the SIS effect on source fields by imposing B⊥( surface)=0 . Sensors consist of 8×8 mm 2 SQUID magnetometers with 0.84 nT/ Φ0 sensitivity and positions and orientations was found. Good agreement was found between modeled and measured shielding of the SQUIDs from sources external to the array showing significant frequency-independent shielding. Phantom localization precision was better than 0.5 mm at all locations with a mean of better than 0.3 mm.

  11. Integrated induction coil and fluxgate magnetometers for EM analysis and monitoring

    Science.gov (United States)

    Hanstein, T.; Strack, K.; Jiang, J.

    2013-12-01

    The concept of a full field array electromagnetic system is an ideal tool to support hydrocarbon and geothermal E & P as well as various engineering monitoring applications. Some of the key questions are defining the reservoir, mapping of the fractures and reservoir depletion monitoring. The reservoirs are all too often relative thin and give an anomalous electromagnetic (EM) response, which is often small in amplitude and challenging for the EM measuring system. A digital fluxgate magnetometer (32-bit) is connected to the KMS magnetotelluric acquisition system with analogue induction coils and electrodes to extend the range of application of a single recording site. Since the noise level is above that of the induction coil for periods shorter than 20 s, the apparent resistivity is biased. For longer periods the apparent resistivity is consistent and eventually better than the induction coil. However, phase and tipper are not biased and agree well with the induction data even for shorter periods. This allows us to develop algorithms that significantly extend the range of application of the fluxgate beyond what was done in the past. The highest frequency of the fluxgate magnetometer is about 180 Hz and the hightest sampling of the FG-board is 4 kHz.The different induction coils and fluxgate magnetometer have intensively been tested in the magnetic chamber and at the field test site near Houston for noise performance by parallel recordings. They show that even in an environment with high cultural noise, the specification can be met. In Northeast China, a 30-day monitoring test with MT was carried out for seismologic applications. Acquisitition schedule included different recordings times and sampling rates. Daily, the data was collected and processed via the internet from either Europe or the US. Even with long recording, we still had to select the time windows for data averaging and coherences are not a good threshhold criteria in this case. During another MT

  12. Magnetorelaxometry of magnetic nanoparticles with fluxgate magnetometers for the analysis of biological targets

    International Nuclear Information System (INIS)

    Ludwig, Frank; Heim, Erik; Maeuselein, Sascha; Eberbeck, Dietmar; Schilling, Meinhard

    2005-01-01

    A magnetorelaxometry system based on sensitive fluxgate magnetometers for the analysis of the relaxation behavior of magnetic nanoparticles is presented. The system is tested with a dilution series of magnetite. The results are directly compared with data obtained with a SQUID magnetorelaxometry system measured on the same samples. Advantages of using fluxgates rather than SQUIDs for magnetorelaxometry are discussed

  13. GaAs nanopillar-array solar cells employing in situ surface passivation

    Science.gov (United States)

    Mariani, Giacomo; Scofield, Adam C.; Hung, Chung-Hong; Huffaker, Diana L.

    2013-01-01

    Arrays of III–V direct-bandgap semiconductor nanopillars represent promising photovoltaic candidates due to their inherent high optical absorption coefficients and minimized reflection arising from light trapping, efficient charge collection in the radial direction and the ability to synthesize them on low-cost platforms. However, the increased surface area results in surface states that hamper the power conversion efficiency. Here, we report the first demonstration of GaAs nanopillar-array photovoltaics employing epitaxial passivation with air mass 1.5 global power conversion efficiencies of 6.63%. High-bandgap epitaxial InGaP shells are grown in situ and cap the radial p–n junctions to alleviate surface-state effects. Under light, the photovoltaic devices exhibit open-circuit voltages of 0.44 V, short-circuit current densities of 24.3 mA cm−2 and fill factors of 62% with high external quantum efficiencies >70% across the spectral regime of interest. A novel titanium/indium tin oxide annealed alloy is exploited as transparent ohmic anode. PMID:23422665

  14. Coupled-core fluxgate magnetometer: Novel configuration scheme and the effects of a noise-contaminated external signal

    International Nuclear Information System (INIS)

    Palacios, Antonio; Aven, John; In, Visarath; Longhini, Patrick; Kho, Andy; Neff, Joseph D.; Bulsara, Adi

    2007-01-01

    Recent theoretical and experimental work has shown that unidirectional coupling can induce oscillations in overdamped and undriven nonlinear dynamical systems that are non-oscillatory when uncoupled; in turn, this has been shown to lead to new mechanisms for weak (compared to the energy barrier height) signal detection and amplification. The potential applications include fluxgate magnetometers, electric field sensors, and arrays of Superconducting Quantum Interference Device (SQUID) rings. In the particular case of the fluxgate magnetometer, we have developed a ''coupled-core fluxgate magnetometer'' (CCFM); this device has been realized in the laboratory and its dynamics used to quantify many properties that are generic to this class of systems and coupling. The CCFM operation is underpinned by the emergent oscillatory behavior in a unidirectionally coupled ring of wound ferromagnetic cores, each of which can be treated as an overdamped bistable dynamic system when uncoupled. In particular, one can determine the regimes of existence and stability of the (coupling-induced) oscillations, and the scaling behavior of the oscillation frequency. More recently, we studied the effects of a (Gaussian) magnetic noise floor on a CCFM system realized with N=3 coupled ferromagnetic cores. In this Letter, we first introduce a variation on the basic CCFM configuration that affords a path to enhanced device sensitivity, particularly for N>=3 coupled elements. We then analyze the response of the basic CCFM configuration as well as the new setup to a dc target signal that has a small noisy component (or ''contamination'')

  15. Calibration of Helmholtz Coils for the characterization of MEMS magnetic sensor using fluxgate magnetometer with DAS1 magnetic range data acquisition system

    Science.gov (United States)

    Ahmad, Farooq; Dennis, John Ojur; Md Khir, Mohd Haris; Hamid, Nor Hisham

    2012-09-01

    This paper presents the calibration of Helmholtz coils for the characterization of MEMS Magnetic sensor using Fluxgate magnetometer with DAS1 Magnetic Range Data Acquisition System. The Helmholtz coils arrangement is often used to generate a uniform magnetic field in space. In the past, standard magnets were used to calibrate the Helmholtz coils. A method is presented here for calibrating these coils using a Fluxgate magnetometer and known current source, which is easier and results in greater accuracy.

  16. Development of Autonomous Magnetometer Rotorcraft For Wide Area Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Mark D. McKay; Matthew O. Anderson

    2011-08-01

    Large areas across the United States and internationally are potentially contaminated with unexploded ordinance (UXO), with some ranges encompassing tens to hundreds of thousands of acres. Technologies are needed which will allow for cost effective wide area scanning with (1) near 100% coverage and (2) near 100% detection of subsurface ordnance or features indicative of subsurface ordnance. The current approach to wide area assessment is a multi-level one, in which medium - altitude fixed wing optical imaging is used for an initial site assessment. This assessment is followed with low altitude manned helicopter based magnetometry. Subsequent to this wide area assessment targeted surface investigations are performed using either towed geophysical sensor arrays or man portable sensors. In order to be an effective tool for small UXO detection, the sensing altitude for magnetic site investigations needs to be on the order of 1 to 3 meters. These altitude requirements mean that manned helicopter surveys will generally only be feasible in large, open and relatively flat terrains. While such surveys are effective in mapping large areas relatively fast there are substantial mobilization/demobilization, staffing and equipment costs associated with these surveys, resulting in costs of approximately $100-$150/acre. In addition, due to the low altitude there are substantial risks to pilots and equipment. Surface towed arrays provide highresolution maps but have other limitations, e.g. in their ability to navigate rough terrain effectively. Thus there is a need for other systems, which can be used for effective data collection. An Unmanned Aerial Vehicle (UAV) magnetometer platform is an obvious alternative. The motivation behind such a system is that it reduces risk to operators, is lower in initial and Operational and Maintenance (O&M) costs (and can thus potentially be applied to smaller sites) and has the potential of being more effective in terms of detection and possibly

  17. Geospace Science from Ground-based Magnetometer Arrays: Advances in Sensors, Data Collection, and Data Integration

    Science.gov (United States)

    Mann, Ian; Chi, Peter

    2016-07-01

    Networks of ground-based magnetometers now provide the basis for the diagnosis of magnetic disturbances associated with solar wind-magnetosphere-ionosphere coupling on a truly global scale. Advances in sensor and digitisation technologies offer increases in sensitivity in fluxgate, induction coil, and new micro-sensor technologies - including the promise of hybrid sensors. Similarly, advances in remote connectivity provide the capacity for truly real-time monitoring of global dynamics at cadences sufficient for monitoring and in many cases resolving system level spatio-temporal ambiguities especially in combination with conjugate satellite measurements. A wide variety of the plasmaphysical processes active in driving geospace dynamics can be monitored based on the response of the electrical current system, including those associated with changes in global convection, magnetospheric substorms and nightside tail flows, as well as due to solar wind changes in both dynamic pressure and in response to rotations of the direction of the IMF. Significantly, any changes to the dynamical system must be communicated by the propagation of long-period Alfven and/or compressional waves. These wave populations hence provide diagnostics for not only the energy transport by the wave fields themselves, but also provide a mechanism for diagnosing the structure of the background plasma medium through which the waves propagate. Ultra-low frequency (ULF) waves are especially significant in offering a monitor for mass density profiles, often invisible to particle detectors because of their very low energy, through the application of a variety of magneto-seismology and cross-phase techniques. Renewed scientific interest in the plasma waves associated with near-Earth substorm dynamics, including magnetosphere-ionosphere coupling at substorm onset and their relation to magnetotail flows, as well the importance of global scale ultra-low frequency waves for the energisation, transport

  18. Development of Next-Generation Borehole Magnetometer and Its Potential Application in Constraining the Magnetic Declination of Oman Samail Ophiolite at ICDP Drill Sites

    Science.gov (United States)

    Lee, S. M.; Parq, J. H.; Kim, H.; Moe, K.; Lee, C. S.; Kanamatsu, T.; Kim, K. J.; Bahk, K. S.

    2017-12-01

    Determining the azimuthal orientation of core samples obtained from deep drilling is extremely difficult because the core itself could have rotated during drilling operations. Several indirect methods have been devised to address this issue, but have certain limitations. Thus it is still a challenge to determine the azimuthal orientation consistently over the entire length of the hole. Provided that the recovery rate is high and thus all the other magnetic properties such as magnetization intensity and inclination are measured from the recovered cores, one possible method for ascertaining magnetic declination information is to measure the magnetic field inside the empty borehole and invert for the best fitting declination. However, there are two major problems: one is that present-day borehole magnetometers are not precise enough to resolve changes in direction of magnetization, and the other is that in most rock drilling experiments the rate of recovery is low. To overcome the first major problem which is technical, scientists from Korea and Japan jointly conducted the development for the next-generation borehole magnetometer, namely 3GBM (3rd Generation Borehole Magnetometer). The borehole magnetometer which uses fiber-optic laser gyro promises to provide accurate information on not only the magnetic field itself but also the orientation of the instrument inside the borehole. Our goal is to deploy this borehole magnetometer in the ICDP Oman Drilling Project Phase 2 drilling experiment early 2018. The site may be suitable for the investigation because, as recent Phase 1 of the Oman Samail Ophiolite drilling has demonstrated, the recovery rate was very high. Also the post-drilling measurements onboard DV Chikyu have shown that much of the recovered samples has moderate magnetization intensity on the order of 0.1 and 1 A/m. Here, we present the results of numerical simulation of magnetic field inside the borehole using finite element method to show that magnetic

  19. Thermodynamics of a closed-cycle gas flow system for cooling a HTc dc-SQUID magnetometer

    NARCIS (Netherlands)

    van den Bosch, P.J.; van den Bosch, P.J.; ter Brake, Hermanus J.M.; van den Eijkel, G.C.; Boelens, J.P.; Holland, Herman J.; Verberne, J.F.C.; Rogalla, Horst

    1994-01-01

    A multichannel high-Tc dc-SQUID based heart-magnetometer is currently under development in our laboratory. The system is cooled by a cooler that, due to its magnetic interference, has to be separated from the SQUID unit. In the present prototype system a closed-cycle gas flow was chosen as the

  20. Ultrasensitive magnetometers based on rotational magnetic excitation

    International Nuclear Information System (INIS)

    Hristoforou, E.; Svec, P. Sr.

    2014-01-01

    Three new types of fluxgate magnetometers are presented in this paper, able to monitor the three components of the ambient field, all of them based on the principle of rotational excitation field. The first type is based on Yttrium- Iron Garnet (YIG) single crystal film, magnetized with rotational field on its plane, where the 2"n"d, 4"t"h and 6"t"h harmonics offer the three components of the ambient field with sensitivity better than 1 pT at 0.2 Hz, its size being 25 cm"3. The second type is based on permalloy film, where the rotational excitation field on its plane offers change of magnetoresistance with sensitivity better than 10 pT at 1 Hz, uncertainty of 1 ppm and size ∼ 8 cm"3. The third type, is based on amorphous film, where the rotation field mode offer sensitivity better than 100 pT at 1 Hz, uncertainty of 10 ppm and size ∼ 10 mm"3. (authors)

  1. Magnetometer-Augmented IMU Simulator: In-Depth Elaboration

    Directory of Open Access Journals (Sweden)

    Thomas Brunner

    2015-03-01

    Full Text Available The location of objects is a growing research topic due, for instance, to the expansion of civil drones or intelligent vehicles. This expansion was made possible through the development of microelectromechanical systems (MEMS, inexpensive and miniaturized inertial sensors. In this context, this article describes the development of a new simulator which generates sensor measurements, giving a specific input trajectory. This will allow the comparison of pose estimation algorithms. To develop this simulator, the measurement equations of every type of sensor have to be analytically determined. To achieve this objective, classical kinematic equations are used for the more common sensors, i.e., accelerometers and rate gyroscopes. As nowadays, the MEMS inertial measurement units (IMUs are generally magnetometer-augmented, an absolute world magnetic model is implemented. After the determination of the perfect measurement (through the error-free sensor models, realistic error models are developed to simulate real IMU behavior. Finally, the developed simulator is subjected to different validation tests.

  2. Coupled-core fluxgate magnetometer: Novel configuration scheme and the effects of a noise-contaminated external signal

    Energy Technology Data Exchange (ETDEWEB)

    Palacios, Antonio [San Diego State University, Nonlinear Dynamical Systems Group, Department of Mathematics and Statistics, San Diego, CA 92182-7720 (United States)]. E-mail: palacios@euler.sdsu.edu; Aven, John [San Diego State University, Nonlinear Dynamical Systems Group, Department of Mathematics and Statistics, San Diego, CA 92182-7720 (United States); In, Visarath [Space and Naval Warfare Systems Center San Diego, Code 2363, 53560 Hull St, San Diego, CA 92152-5001 (United States)]. E-mail: visarath@spawar.navy.mil; Longhini, Patrick [Space and Naval Warfare Systems Center San Diego, Code 2363, 53560 Hull St, San Diego, CA 92152-5001 (United States); Kho, Andy [Space and Naval Warfare Systems Center San Diego, Code 2363, 53560 Hull St, San Diego, CA 92152-5001 (United States); Neff, Joseph D. [Space and Naval Warfare Systems Center San Diego, Code 2363, 53560 Hull St, San Diego, CA 92152-5001 (United States); Bulsara, Adi [Space and Naval Warfare Systems Center San Diego, Code 2363, 53560 Hull St, San Diego, CA 92152-5001 (United States)]. E-mail: bulsara@spawar.navy.mil

    2007-07-16

    Recent theoretical and experimental work has shown that unidirectional coupling can induce oscillations in overdamped and undriven nonlinear dynamical systems that are non-oscillatory when uncoupled; in turn, this has been shown to lead to new mechanisms for weak (compared to the energy barrier height) signal detection and amplification. The potential applications include fluxgate magnetometers, electric field sensors, and arrays of Superconducting Quantum Interference Device (SQUID) rings. In the particular case of the fluxgate magnetometer, we have developed a ''coupled-core fluxgate magnetometer'' (CCFM); this device has been realized in the laboratory and its dynamics used to quantify many properties that are generic to this class of systems and coupling. The CCFM operation is underpinned by the emergent oscillatory behavior in a unidirectionally coupled ring of wound ferromagnetic cores, each of which can be treated as an overdamped bistable dynamic system when uncoupled. In particular, one can determine the regimes of existence and stability of the (coupling-induced) oscillations, and the scaling behavior of the oscillation frequency. More recently, we studied the effects of a (Gaussian) magnetic noise floor on a CCFM system realized with N=3 coupled ferromagnetic cores. In this Letter, we first introduce a variation on the basic CCFM configuration that affords a path to enhanced device sensitivity, particularly for N>=3 coupled elements. We then analyze the response of the basic CCFM configuration as well as the new setup to a dc target signal that has a small noisy component (or ''contamination'')

  3. Note: Readout of a micromechanical magnetometer for the ITER fusion reactor

    International Nuclear Information System (INIS)

    Rimminen, H.; Kyynäräinen, J.

    2013-01-01

    We present readout instrumentation for a MEMS magnetometer, placed 30 m away from the MEMS element. This is particularly useful when sensing is performed in high-radiation environment, where the semiconductors in the readout cannot survive. High bandwidth transimpedance amplifiers are used to cancel the cable capacitances of several nanofarads. A frequency doubling readout scheme is used for crosstalk elimination. Signal-to-noise ratio in the range of 60 dB was achieved and with sub-percent nonlinearity. The presented instrument is intended for the steady-state magnetic field measurements in the ITER fusion reactor.

  4. A three-axis SQUID-based absolute vector magnetometer

    Energy Technology Data Exchange (ETDEWEB)

    Schönau, T.; Schmelz, M.; Stolz, R.; Anders, S.; Linzen, S.; Meyer, H.-G. [Department of Quantum Detection, Leibniz Institute of Photonic Technology, Jena 07745 (Germany); Zakosarenko, V.; Meyer, M. [Supracon AG, An der Lehmgrube 11, Jena 07751 (Germany)

    2015-10-15

    We report on the development of a three-axis absolute vector magnetometer suited for mobile operation in the Earth’s magnetic field. It is based on low critical temperature dc superconducting quantum interference devices (LTS dc SQUIDs) with sub-micrometer sized cross-type Josephson junctions and exhibits a white noise level of about 10 fT/Hz{sup 1/2}. The width of superconducting strip lines is restricted to less than 6 μm in order to avoid flux trapping during cool-down in magnetically unshielded environment. The long-term stability of the flux-to-voltage transfer coefficients of the SQUID electronics is investigated in detail and a method is presented to significantly increase their reproducibility. We further demonstrate the long-term operation of the setup in a magnetic field varying by about 200 μT amplitude without the need for recalibration.

  5. Hypervelocity dust particle impacts observed by the Giotto Magnetometer and Plasma Experiments

    OpenAIRE

    Neubauer, F. M.; Glassmeier, K. H.; Coates, A. J.; Goldstein, R.; Acuña, M. H.; Musmann, G.

    1990-01-01

    We report thirteen very short events in the magnetic field of the inner magnetic pile‐up region of comet Halley observed by the Giotto magnetometer experiment together with simultaneous plasma data obtained by the Johnstone plasma analyzer and the ion mass spectrometer experiments. The events are due to dust impacts in the milligram range on the spacecraft at the relative velocity between the cemetery dust and the spacecraft of 68 km/sec. They are generally consistent with dust impact events ...

  6. Associating ground magnetometer observations with current or voltage generators

    DEFF Research Database (Denmark)

    Hartinger, M. D.; Xu, Z.; Clauer, C. R.

    2017-01-01

    A circuit analogy for magnetosphere-ionosphere current systems has two extremes for driversof ionospheric currents: ionospheric elec tric fields/voltages constant while current/conductivity vary—the“voltage generator”—and current constant while electric field/conductivity vary—the “current generator.......”Statistical studies of ground magnetometer observations associated with dayside Transient High LatitudeCurrent Systems (THLCS) driven by similar mechanisms find contradictory results using this paradigm:some studies associate THLCS with voltage generators, others with current generators. We argue that mostof...... these two assumptions substantially alter expectations for magnetic perturbations associatedwith either a current or a voltage generator. Our results demonstrate that before interpreting groundmagnetometer observations of THLCS in the context of current/voltage generators, the location...

  7. Magnetic profiling of the San Andreas Fault using a dual magnetometer UAV aerial survey system.

    Science.gov (United States)

    Abbate, J. A.; Angelopoulos, V.; Masongsong, E. V.; Yang, J.; Medina, H. R.; Moon, S.; Davis, P. M.

    2017-12-01

    Aeromagnetic survey methods using planes are more time-effective than hand-held methods, but can be far more expensive per unit area unless large areas are covered. The availability of low cost UAVs and low cost, lightweight fluxgate magnetometers (FGMs) allows, with proper offset determination and stray fields correction, for low-cost magnetic surveys. Towards that end, we have developed a custom multicopter UAV for magnetic mapping using a dual 3-axis fluxgate magnetometer system: the GEOphysical Drone Enhanced Survey Instrument (GEODESI). A high precision sensor measures the UAV's position and attitude (roll, pitch, and yaw) and is recorded using a custom Arduino data processing system. The two FGMs (in-board and out-board) are placed on two ends of a vertical 1m boom attached to the base of the UAV. The in-board FGM is most sensitive to stray fields from the UAV and its signal is used, after scaling, to clean the signal of the out-board FGM from the vehicle noise. The FGMs record three orthogonal components of the magnetic field in the UAV body coordinates which are then transformed into a north-east-down coordinate system using a rotation matrix determined from the roll-pitch-yaw attitude data. This ensures knowledge of the direction of all three field components enabling us to perform inverse modeling of magnetic anomalies with greater accuracy than total or vertical field measurements used in the past. Field tests were performed at Dragon's Back Pressure Ridge in the Carrizo Plain of California, where there is a known crossing of the San Andreas Fault. Our data and models were compared to previously acquired LiDAR and hand-held magnetometer measurements. Further tests will be carried out to solidify our results and streamline our processing for educational use in the classroom and student field training.

  8. NEWTON - NEW portable multi-sensor scienTific instrument for non-invasive ON-site characterization of rock from planetary surface and sub-surfaces

    Science.gov (United States)

    Díaz-Michelena, M.; de Frutos, J.; Ordóñez, A. A.; Rivero, M. A.; Mesa, J. L.; González, L.; Lavín, C.; Aroca, C.; Sanz, M.; Maicas, M.; Prieto, J. L.; Cobos, P.; Pérez, M.; Kilian, R.; Baeza, O.; Langlais, B.; Thébault, E.; Grösser, J.; Pappusch, M.

    2017-09-01

    In space instrumentation, there is currently no instrument dedicated to susceptibly or complete magnetization measurements of rocks. Magnetic field instrument suites are generally vector (or scalar) magnetometers, which locally measure the magnetic field. When mounted on board rovers, the electromagnetic perturbations associated with motors and other elements make it difficult to reap the benefits from the inclusion of such instruments. However, magnetic characterization is essential to understand key aspects of the present and past history of planetary objects. The work presented here overcomes the limitations currently existing in space instrumentation by developing a new portable and compact multi-sensor instrument for ground breaking high-resolution magnetic characterization of planetary surfaces and sub-surfaces. This new technology introduces for the first time magnetic susceptometry (real and imaginary parts) as a complement to existing compact vector magnetometers for planetary exploration. This work aims to solve the limitations currently existing in space instrumentation by means of providing a new portable and compact multi-sensor instrument for use in space, science and planetary exploration to solve some of the open questions on the crustal and more generally planetary evolution within the Solar System.

  9. Fluxgate vector magnetometers: A multisensor device for ground, UAV, and airborne magnetic surveys

    OpenAIRE

    Gavazzi , Bruno; Le Maire , Pauline; Munschy , Marc; Dechamp , Aline

    2016-01-01

    International audience; Fluxgate magnetometers are quite uncommon in geophysics. Recent advances in calibration of the devices and their magnetic compensation ability led Institut de Physique du Globe de Stras-bourg to develop instruments for magnetic measurements at different scales for a wide range of applications — from submetric measurements on the ground to aircraft-conducted acquisition by unmanned aerial vehicles (UAVs). A case study on the aerial military base BA112 shows the usefulne...

  10. Setup and taking into operation of a highly sensitive 3He magnetometer for a future experiment for the determination of an electric dipole moment of the free neutron

    International Nuclear Information System (INIS)

    Kraft, Andreas

    2012-01-01

    The measurement of the electric dipole moment of the free neutron is directly linked to the question on the accurate determination of the magnetic field conditions inside the nEDM spectrometer. Using in-situ the spin-precession of polarized 3 He, monitored by optically pumped Cs-magnetometers a sensitivity on the femto-tesla-scale can be obtained. At the institute of physics of the University Mainz a 3 He/Cs-test facility was built to investigate the readout of 3 He-spin-precession with a lamp-pumped Cs-magnetometer. Additionally, an ultra-compact and transportable polarizer unit was developed and installed in Mainz, which polarizes 3 He gas up to 55 % of polarization before the compressed gas is delivered to two sandwich magnetometer cells inside the EDM chamber. This theses will present some results of the first successful test of the polarizer unit in January 2012. 3 He was polarized in the ultra compact polarizer unit and transferred via guiding fields into a 4 layer mu-metal shield, where the free spin precession was detected with a lamp pumped Cs-magnetometer.

  11. Development, construction and analysis of the "Ørsted" fluxgate magnetometer

    DEFF Research Database (Denmark)

    Nielsen, Otto V; Petersen, Jan Raagaard; Primdahl, Fritz

    1995-01-01

    glass ribbons as core materials. It is shown that very simple physical models can be used to explain the fluxgate mode of operation, thereby making it easy to calculate the overall sensor performance from first principles. Special attention is drawn to the core excitation current which is analysed...... in the instrument (±65 536 nT with 0.5 nT resolution). The maximum attainablebandwidth is half the sensor excitation frequency (½ x 15 kHz) but the Ørsted magnetometer bandwidth is limited to 250 Hz. The thermal stability of the sensor has been measured to be better than 1 nT in the temperature range -20 to +60°C....

  12. Elimination of the induced current error in magnetometers using superconducting flux transformers

    International Nuclear Information System (INIS)

    Dummer, D.; Weyhmann, W.

    1987-01-01

    The changing magnetization of a sample in a superconducting flux transformer coupled magnetometer induces a current in the transformer which in turn changes the field at the sample. This ''image'' field and the error caused by it can be eliminated by sensing the current in the loop and nulling it by feedback through a mutual inductance. We have tested the technique on the superconducting transition of indium in an applied magnetic field and shown that the observed width of the transition is greatly reduced by maintaining zero current in the flux transformer

  13. The Search-Coil Magnetometer for MMS

    Science.gov (United States)

    Le Contel, O.; Leroy, P.; Roux, A.; Coillot, C.; Alison, D.; Bouabdellah, A.; Mirioni, L.; Meslier, L.; Galic, A.; Vassal, M. C.; Torbert, R. B.; Needell, J.; Rau, D.; Dors, I.; Ergun, R. E.; Westfall, J.; Summers, D.; Wallace, J.; Magnes, W.; Valavanoglou, A.; Olsson, G.; Chutter, M.; Macri, J.; Myers, S.; Turco, S.; Nolin, J.; Bodet, D.; Rowe, K.; Tanguy, M.; de la Porte, B.

    2016-03-01

    The tri-axial search-coil magnetometer (SCM) belongs to the FIELDS instrumentation suite on the Magnetospheric Multiscale (MMS) mission (Torbert et al. in Space Sci. Rev. (2014), this issue). It provides the three magnetic components of the waves from 1 Hz to 6 kHz in particular in the key regions of the Earth's magnetosphere namely the subsolar region and the magnetotail. Magnetospheric plasmas being collisionless, such a measurement is crucial as the electromagnetic waves are thought to provide a way to ensure the conversion from magnetic to thermal and kinetic energies allowing local or global reconfigurations of the Earth's magnetic field. The analog waveforms provided by the SCM are digitized and processed inside the digital signal processor (DSP), within the Central Electronics Box (CEB), together with the electric field data provided by the spin-plane double probe (SDP) and the axial double probe (ADP). On-board calibration signal provided by DSP allows the verification of the SCM transfer function once per orbit. Magnetic waveforms and on-board spectra computed by DSP are available at different time resolution depending on the selected mode. The SCM design is described in details as well as the different steps of the ground and in-flight calibrations.

  14. High temperature superconductor micro-superconducting-quantum-interference-device magnetometer for magnetization measurement of a microscale magnet.

    Science.gov (United States)

    Takeda, Keiji; Mori, Hatsumi; Yamaguchi, Akira; Ishimoto, Hidehiko; Nakamura, Takayoshi; Kuriki, Shinya; Hozumi, Toshiya; Ohkoshi, Shin-ichi

    2008-03-01

    We have developed a high temperature superconductor (HTS) micrometer-sized dc superconducting quantum interference device (SQUID) magnetometer for high field and high temperature operation. It was fabricated from YBa2Cu3O7-delta of 92 nm in thickness with photolithography techniques to have a hole of 4x9 microm2 and 2 microm wide grain boundary Josephson junctions. Combined with a three dimensional magnetic field coil system, the modulation patterns of critical current Ic were observed for three different field directions. They were successfully used to measure the magnetic properties of a molecular ferrimagnetic microcrystal (23x17x13 microm3), [Mn2(H2O)2(CH3COO)][W(CN)8]2H2O. The magnetization curve was obtained in magnetic field up to 0.12 T between 30 and 70 K. This is the first to measure the anisotropy of hysteresis curve in the field above 0.1 T with an accuracy of 10(-12) J T(-1) (10(-9) emu) with a HTS micro-SQUID magnetometer.

  15. High-Sensitivity Low-Noise Miniature Fluxgate Magnetometers Using a Flip Chip Conceptual Design

    OpenAIRE

    Lu, Chih-Cheng; Huang, Jeff; Chiu, Po-Kai; Chiu, Shih-Liang; Jeng, Jen-Tzong

    2014-01-01

    This paper presents a novel class of miniature fluxgate magnetometers fabricated on a print circuit board (PCB) substrate and electrically connected to each other similar to the current “flip chip” concept in semiconductor package. This sensor is soldered together by reversely flipping a 5 cm × 3 cm PCB substrate to the other identical one which includes dual magnetic cores, planar pick-up coils, and 3-D excitation coils constructed by planar Cu interconnections patterned on PCB substrates. P...

  16. Demonstration of the SeptiStrand benthic microbial fuel cell powering a magnetometer for ship detection

    Science.gov (United States)

    Arias-Thode, Y. Meriah; Hsu, Lewis; Anderson, Greg; Babauta, Jerome; Fransham, Roy; Obraztsova, Anna; Tukeman, Gabriel; Chadwick, D. Bart

    2017-07-01

    The Navy has a need for monitoring conditions and gathering information in marine environments. Sensors can monitor and report environmental parameters and potential activities such as animal movements, ships, or personnel. However, there has to be a means to power these sensors. One promising enabling technology that has been shown to provide long-term power production in underwater environments is the benthic microbial fuel cells (BMFC). BMFCs are devices that generate energy by coupling bioanodes and biocathodes through an external energy harvester. Recent studies have demonstrated success for usage of BMFCs in powering small instruments and other devices on the seafloor over limited periods of time. In this effort, a seven-stranded BMFC linear array of 30 m was designed to power a seafloor magnetometer to detect passing ship movements through Pearl Harbor, Hawaii. The BMFC system was connected to a flyback energy harvesting circuit that charged the battery powering the magnetometer. The deployment was demonstrated the BMFC supplied power to the battery for approximately 38 days. This is the first large-scale demonstration system for usage of the SeptiStrand BMFC technology to power a relevant sensor.

  17. Counter electrojet features in the Brazilian sector: simultaneous observation by radar, digital sounder and magnetometers

    Directory of Open Access Journals (Sweden)

    C. M. Denardini

    2009-04-01

    Full Text Available In the present work we show new results regarding equatorial counter electrojet (CEJ events in the Brazilian sector, based on the RESCO radar, two set of fluxgate magnetometer systems and a digital sounder. RESCO radar is a 50 MHz backscatter coherent radar installed in 1998 at São Luís (SLZ, 2.33° S, 44.60° W, an equatorial site. The Digital sounder routinely monitors the electron density profile at the radar site. The magnetometer systems are fluxgate-type installed at SLZ and Eusébio (EUS, 03.89° S, 38.44° W. From the difference between the horizontal component of magnetic field at SLZ station and the same component at EUS (EEJ ground strength several cases of westward morning electrojet and its normal inversion to the eastward equatorial electrojet (EEJ have been observed. Also, the EEJ ground strength has shown some cases of CEJ events, which been detected with the RESCO radar too. Detection of these events were investigated with respect to their time and height of occurrence, correlation with sporadic E (Es layers at the same time, and their spectral characteristics as well as the radar echo power intensity.

  18. Airborne gamma-ray spectrometer and magnetometer survey, Meade River Quadrangle, Alaska. Final report

    International Nuclear Information System (INIS)

    1981-02-01

    The results obtained from an airborne high sensitivity gamma-ray spectrometer and magnetometer survey over the Meade River map area of Alaska are presented. Based on the criteria outlined in the general section on interpretation, a total of eight uranium anomalies have been outlined on the interpretation map. Most of these are only weakly to moderately anomalous. Zones 3 and 7 are relatively better than the others though none of the anomalies are thought to be of any economic significance. No follow-up work is recommended

  19. Airborne gamma-ray spectrometer and magnetometer survey: north/south tieline. Final report

    International Nuclear Information System (INIS)

    1981-05-01

    An airborne high sensitivity gamma-ray spectrometer and magnetometer survey was conducted along the 99 0 longitude meridian from the Canadian border southward to the Mexican border. A total of 1555 line miles of geophysical data were acquired and, subsequently, compiled. The north-south tieline was flown as part of the National Uranium Resources Evaluation. NURE is a program of the US Department of Energy's Grand Junction, Colorado, office to acquire and compile geologic and other information with which to assess the magnitude and distribution of uranium resources and to determine areas favorable for the occurrence of uranium in the United States

  20. Airborne gamma-ray spectrometer and magnetometer survey, Sagavanirktok Quadrangle, Alaska. Volume I. Final report

    International Nuclear Information System (INIS)

    1981-03-01

    The results obtained from an airborne high sensitivity gamma-ray spectrometer and magnetometer survey over the Sagavanirktok map area of Alaska are presented. Based on the criteria outlined in the general section on interpretation, a total of eight uranium anomalies have been outlined on the interpretation map. However, all of these zones are only weakly to moderately anomalous. None are thought to be indicative of local enrichment of uranium to economically significant levels. No follow-up work is recommended

  1. Sensitivity of proposed search for axion-induced magnetic field using optically pumped magnetometers

    Science.gov (United States)

    Chu, P.-H.; Duffy, L. D.; Kim, Y. J.; Savukov, I. M.

    2018-04-01

    We investigate the sensitivity of a search for the oscillating current induced by axion dark matter in an external magnetic field using optically pumped magnetometers. This experiment is based upon the LC circuit (circuit with inductor and capacitor) axion detection concept of Sikivie et al. [Phys. Rev. Lett. 112, 131301 (2014), 10.1103/PhysRevLett.112.131301]. The modification of Maxwell's equations caused by the axion-photon coupling results in a minute magnetic field oscillating at a frequency equal to the axion mass, in the presence of an external magnetic field. The axion-induced magnetic field could be searched for using a LC circuit amplifier with an optically pumped magnetometer, the most sensitive cryogen-free magnetic-field sensor, in a room-temperature experiment, avoiding the need for a complicated and expensive cryogenic system. We discuss how an existing magnetic resonance imaging experiment can be modified to search for axions in a previously unexplored part of the parameter space. Our existing detection setup, optimized for magnetic resonance imagining, is already sensitive to an axion-photon coupling of 10-7 GeV-1 for an axion mass near 3 ×10-10 eV , which is already limited by astrophysical processes and solar axion searches. We show that realistic modifications, and optimization of the experiment for axion detection, can probe the axion-photon coupling up to 4 orders of magnitude beyond the current best limit, for axion masses between 10-11 and 10-7 eV .

  2. Simulation and measurement of ferromagnetic impurities in non-magnetic aeroengine turbine disks using fluxgate magnetometers

    OpenAIRE

    Sebastian Hantscher; Ruixin Zhou; Albert Seidl; Johann Hinken; Christian Ziep

    2015-01-01

    In this paper, ferromagnetic impurities in paramagnetic aeroengine turbine disks are investigated. Because such inclusions represent a significant threat in aviation, a detailed analysis is required for impured turbine disks. For this purpose, sensitive fluxgate magnetometers are used. After a premagnetisation, this sensor is able to detect small ferromagnetic particles by recording the variation of the magnetic flux density while the disk rotates below the sensor head. This trajectory create...

  3. Geophysical Surveying of Shallow Magnetic Anomalies Using the iPhone Magnetometer

    Science.gov (United States)

    Opdyke, P.; Dudley, C.; Louie, J. N.

    2012-12-01

    This investigation examined whether the 3-axis Hall-effect magnetometer in the Apple iPhone 3GS can function as an effective shallow magnetic survey instrument. The xSensor Pro app from Crossbow Systems allows recoding of all three sensor components along with the GPS location, at a frequency of 1.0, 4.0, 16.0, and 32.0 Hz. If the iPhone proves successful in collecting useful magnetic data, then geophysicists and especially educators would have a new tool for high-density geophysical mapping. No-contract iPhones that can connect with WiFi can be obtained for about $400, allowing deployment of large numbers of instruments. iPhones with the xSensor Pro app surveyed in parallel with an Overhauser GEM system magnetometer (1 nT sensitivity) to test this idea. Anderson Bay, located on the Pyramid Lake Paiute Reservation, provided a rural survey location free from cultural interference. xSensor Pro, logged each component's intensity and the GPS location at a frequency of four measurements per second. Two Overhauser units functioned as a base unit and a roving unit. The roving unit collected total field at set points located with a handheld GPS. Comparing the total field computed from the iPhone components against that collected by the Overhauser establishes the level of anomalies that the iPhone can detect. iPhone total-field measurements commonly vary by 200 nT from point to point, so a spatial-temporal average over 25 seconds produces a smoothed signal for comparison. Preliminary analysis of the iPhone results show that the data do not accurately correlate to the total field collected by the Overhauser for any anomaly of less than 200 nT.

  4. Is light narrowing possible with dense-vapor paraffin coated cells for atomic magnetometers?

    Science.gov (United States)

    Han, Runqi; Balabas, Mikhail; Hovde, Chris; Li, Wenhao; Roig, Hector Masia; Wang, Tao; Wickenbrock, Arne; Zhivun, Elena; You, Zheng; Budker, Dmitry

    2017-12-01

    We investigated the operation of an all-optical rubidium-87 atomic magnetometer with amplitude-modulated light. To study the suppression of spin-exchange relaxation, three schemes of pumping were implemented with room-temperature and heated paraffin coated vacuum cells. Efficient pumping and accumulation of atoms in the F=2 ground state were obtained. However, the sought-for narrowing of the resonance lines has not been achieved. A theoretical analysis of the polarization degree is presented to illustrate the absence of light narrowing due to radiation trapping at high temperature.

  5. In-situ measurement of magnetic field gradient in a magnetic shield by a spin-exchange relaxation-free magnetometer

    International Nuclear Information System (INIS)

    Fang Jian-Cheng; Wang Tao; Li Yang; Cai Hong-Wei; Zhang Hong

    2015-01-01

    A method of measuring in-situ magnetic field gradient is proposed in this paper. The magnetic shield is widely used in the atomic magnetometer. However, there is magnetic field gradient in the magnetic shield, which would lead to additional gradient broadening. It is impossible to use an ex-situ magnetometer to measure magnetic field gradient in the region of a cell, whose length of side is several centimeters. The method demonstrated in this paper can realize the in-situ measurement of the magnetic field gradient inside the cell, which is significant for the spin relaxation study. The magnetic field gradients along the longitudinal axis of the magnetic shield are measured by a spin-exchange relaxation-free (SERF) magnetometer by adding a magnetic field modulation in the probe beam’s direction. The transmissivity of the cell for the probe beam is always inhomogeneous along the pump beam direction, and the method proposed in this paper is independent of the intensity of the probe beam, which means that the method is independent of the cell’s transmissivity. This feature makes the method more practical experimentally. Moreover, the AC-Stark shift can seriously degrade and affect the precision of the magnetic field gradient measurement. The AC-Stark shift is suppressed by locking the pump beam to the resonance of potassium’s D1 line. Furthermore, the residual magnetic fields are measured with σ + - and σ – -polarized pump beams, which can further suppress the effect of the AC-Stark shift. The method of measuring in-situ magnetic field gradient has achieved a magnetic field gradient precision of better than 30 pT/mm. (paper)

  6. Prospecting For Magnetite Ore Deposits With A Innovative Sensor's of Unique Fundamentally New Magnetometer.

    Science.gov (United States)

    Emelianenko, T. I.; Tachaytdinov, R. S.; Sarichev, V. F.; Kotov, B. V.; Susoeva, G. N.

    After careful study of principles and abilities of all existing magnetmeters of all three revolutions in magnetic prospecting we have come to the conclusion that they cannot solve local guestions of the magnetic prospecting or determine centre coordinates of magnetite ore body before drilling Electromagnetism lows and achievents magnetprospectings and radioelectronics of all 20th century serve as a theoretical base of the "locator". While creating this cardinally new magnetmeter , we borrowed different things from radio-prospectors, magnetprospectors, wireless operators and combined all of them while creating the "locators''. The "locators' construction is bas ed on the "magnetic intensification" principle ,owing to which this "locators" are characterised by hight sensitiveness and ability to determine centers of even little commercial magnetite ore deposits with relatively weak magnetic anomalies. The main advantage of the "locators" over existing ones is that it can solve local questions determine centre coordinates. A remarkably simple locator construction determine direction of the on-surface measurings towards the ore body centre and gives approximate prognosis resourses before/withour/ drilling. The "locators" were worked out for the first time in history , they have 2 licences. The fundamental design and drawbacks of the existing magnetometers have been inherited from the original magnetometre dating back two or three hundred years. The developers of the existing magnetometres have all gone along the same well- beaten track of replacing the primitive sensor in the form of a piece of ore hung on a string at first by an arrow sensor and later by magnetically oriented protons and quanta, with amplification of the sensors' OUTPUT signal. Furthermore, all the existing magnetometres are imperfect in that they, lacking the directivity of the ground-level magnetic measurements, only record the overall magnetic vector field generated by all the ore bodies around the

  7. 49 CFR 1014.140 - Employment.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 8 2010-10-01 2010-10-01 false Employment. 1014.140 Section 1014.140... HANDICAP IN PROGRAMS OR ACTIVITIES CONDUCTED BY THE SURFACE TRANSPORTATION BOARD § 1014.140 Employment. No qualified handicapped person shall, on the basis of handicap, be subjected to discrimination in employment...

  8. A summary of the results from the UCLA OGO-5 fluxgate magnetometer

    Science.gov (United States)

    Coleman, P. J., Jr.; Russell, C. T.

    1973-01-01

    The OGO-5 fluxgate magnetometer experiment (E-14) was designed to measure the vector magnetic field over the full range of the OGO-5 orbit. Thus, it had a dynamic range of + or - 64,000 gamma yet it maintained a precision of + or - 1/16 gamma at all times. This enabled a broad spectrum of problems to be attached. Studies of the magnetospheric waves, currents, waves-particle interactions, pitch angle distributions and wave normal directions were made. The structure of the magnetopause, the magnetotail, and bow shock were probed, waves and discontinuities in the solar wind were examined and the various phases of substorms were examined in depth.

  9. Airborne gamma-ray spectrometer and magnetometer survey, Wainwright Quadrangle, Alaska. Final report

    International Nuclear Information System (INIS)

    1981-03-01

    The results obtained from a gamma-ray spectrometer and magnetometer survey over the Wainwright map area of Alaska are presented. Based on the criteria outlined in the general section of interpretation, a total of seven uranium anomalies have been outlined on the interpretation map. With the exception of Anomaly 1, all are located over the higher terrain of the foothills in the southern portion of the quadrangle. All seven anomalies are only weakly to moderately anomalous. There are no indications anywhere within the area of any significant preferential accumulations of uranium. None of the anomalies are thought to be of any economic importance. No follow-up work is recommended

  10. Apparatus for measurement of the electric dipole moment of the neutron using a cohabiting atomic-mercury magnetometer

    Energy Technology Data Exchange (ETDEWEB)

    Baker, C.A. [Rutherford Appleton Laboratory, Chilton, Didcot, Oxon OX11 0QX (United Kingdom); Chibane, Y.; Chouder, M. [University of Sussex, Falmer, Brighton BN1 9QH (United Kingdom); Geltenbort, P. [Institut Laue-Langevin, BP 156, F-38042 Grenoble Cedex 9 (France); Green, K. [Rutherford Appleton Laboratory, Chilton, Didcot, Oxon OX11 0QX (United Kingdom); Harris, P.G., E-mail: p.g.harris@sussex.ac.uk [University of Sussex, Falmer, Brighton BN1 9QH (United Kingdom); Heckel, B.R. [Department of Physics, University of Washington, Seattle, WA 98195 (United States); Iaydjiev, P.; Ivanov, S.N.; Kilvington, I. [Rutherford Appleton Laboratory, Chilton, Didcot, Oxon OX11 0QX (United Kingdom); Lamoreaux, S.K. [Department of Physics, University of Washington, Seattle, WA 98195 (United States); May, D.J.; Pendlebury, J.M.; Richardson, J.D.; Shiers, D.B.; Smith, K.F. [University of Sussex, Falmer, Brighton BN1 9QH (United Kingdom); Grinten, M. van der [Rutherford Appleton Laboratory, Chilton, Didcot, Oxon OX11 0QX (United Kingdom)

    2014-02-01

    A description is presented of apparatus used to carry out an experimental search for an electric dipole moment of the neutron, at the Institut Laue-Langevin (ILL), Grenoble. The experiment incorporated a cohabiting atomic-mercury magnetometer in order to reduce spurious signals from magnetic field fluctuations. The result has been published in an earlier letter [1]; here, the methods and equipment used are discussed in detail.

  11. Airborne gamma-ray spectrometer and magnetometer survey: Aberdeen quadrangle, South Dakota. Final report

    International Nuclear Information System (INIS)

    1981-04-01

    During the months of June through October, 1980, Aero Service Division Western Geophysical Company of America conducted an airborne high sensitivity gamma-ray spectrometer and magnetometer survey over eleven (11) 2 0 x 1 0 NTMS quadrangles located in the states of Minnesota and Wisconsin and seven (7) 2 0 x 1 0 NTMS quadrangles in North and South Dakota. This report discusses the results obtained over the Aberdeen, South Dakota map area. The final data are presented in four different forms: on magnetic tape; on microfiche; in graphic form as profiles and histograms; and in map form as anomaly maps, flight path maps, and computer printer maps

  12. Airborne gamma-ray spectrometer and magnetometer survey, Point Lay Quadrangle, Alaska. Volume I. Final report

    International Nuclear Information System (INIS)

    1981-02-01

    The results obtained from an airborne high sensitivity gamma-ray spectrometer and magnetometer survey over the Point Lay map area of Alaska are presented. Based on the criteria outlined in the general section on interpretation, a total of six uranium anomalies have been indicated on the interpretation map. All six are only weakly to moderately anomalous in either uranium or the uranium ratios. None of these are thought to be of any economic significance. No follow-up work is recommended for the Point Lay Quadrangle

  13. Airborne gamma-ray spectrometer and magnetometer survey: Harrison Bay Quadrangle, Alaska. Final report, Volume 1

    International Nuclear Information System (INIS)

    1981-02-01

    During the months of July and August of 1980, Aero Service Division Western Geophysical Company of America conducted an airborne high sensitivity gamma-ray spectrometer and magnetometer survey over eleven (11) 3 0 x 1 0 and one (1) 4 0 x 1 0 NTMS quadrangles of the Alaska North Slope. These include the Barrow, Wainwright, Meade River, Teshekpuk, Harrison Bay, Beechey Point, Point Lay, Utukok River, Lookout Ridge, Ikpikpuk River, Umiat, and Sagavanirktok quadrangles. This report discusses the results obtained over the Harrison Bay map area

  14. Digitally controlled high-performance dc SQUID readout electronics for a 304-channel vector magnetometer

    Science.gov (United States)

    Bechstein, S.; Petsche, F.; Scheiner, M.; Drung, D.; Thiel, F.; Schnabel, A.; Schurig, Th

    2006-06-01

    Recently, we have developed a family of dc superconducting quantum interference device (SQUID) readout electronics for several applications. These electronics comprise a low-noise preamplifier followed by an integrator, and an analog SQUID bias circuit. A highly-compact low-power version with a flux-locked loop bandwidth of 0.3 MHz and a white noise level of 1 nV/√Hz was specially designed for a 304-channel low-Tc dc SQUID vector magnetometer, intended to operate in the new Berlin Magnetically Shielded Room (BMSR-2). In order to minimize the space needed to mount the electronics on top of the dewar and to minimize the power consumption, we have integrated four electronics channels on one 3 cm × 10 cm sized board. Furthermore we embedded the analog components of these four channels into a digitally controlled system including an in-system programmable microcontroller. Four of these integrated boards were combined to one module with a size of 4 cm × 4 cm × 16 cm. 19 of these modules were implemented, resulting in a total power consumption of about 61 W. To initialize the 304 channels and to service the system we have developed software tools running on a laptop computer. By means of these software tools the microcontrollers are fed with all required data such as the working points, the characteristic parameters of the sensors (noise, voltage swing), or the sensor position inside of the vector magnetometer system. In this paper, the developed electronics including the software tools are described, and first results are presented.

  15. Digitally controlled high-performance dc SQUID readout electronics for a 304-channel vector magnetometer

    International Nuclear Information System (INIS)

    Bechstein, S; Petsche, F; Scheiner, M; Drung, D; Thiel, F; Schnabel, A; Schurig, Th

    2006-01-01

    Recently, we have developed a family of dc superconducting quantum interference device (SQUID) readout electronics for several applications. These electronics comprise a low-noise preamplifier followed by an integrator, and an analog SQUID bias circuit. A highly-compact low-power version with a flux-locked loop bandwidth of 0.3 MHz and a white noise level of 1 nV/√Hz was specially designed for a 304-channel low-T c dc SQUID vector magnetometer, intended to operate in the new Berlin Magnetically Shielded Room (BMSR-2). In order to minimize the space needed to mount the electronics on top of the dewar and to minimize the power consumption, we have integrated four electronics channels on one 3 cm x 10 cm sized board. Furthermore we embedded the analog components of these four channels into a digitally controlled system including an in-system programmable microcontroller. Four of these integrated boards were combined to one module with a size of 4 cm x 4 cm x 16 cm. 19 of these modules were implemented, resulting in a total power consumption of about 61 W. To initialize the 304 channels and to service the system we have developed software tools running on a laptop computer. By means of these software tools the microcontrollers are fed with all required data such as the working points, the characteristic parameters of the sensors (noise, voltage swing), or the sensor position inside of the vector magnetometer system. In this paper, the developed electronics including the software tools are described, and first results are presented

  16. Digitally controlled high-performance dc SQUID readout electronics for a 304-channel vector magnetometer

    Energy Technology Data Exchange (ETDEWEB)

    Bechstein, S [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany); Petsche, F [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany); Scheiner, M [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany); Drung, D [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany); Thiel, F [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany); Schnabel, A [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany); Schurig, Th [Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin (Germany)

    2006-06-01

    Recently, we have developed a family of dc superconducting quantum interference device (SQUID) readout electronics for several applications. These electronics comprise a low-noise preamplifier followed by an integrator, and an analog SQUID bias circuit. A highly-compact low-power version with a flux-locked loop bandwidth of 0.3 MHz and a white noise level of 1 nV/{radical}Hz was specially designed for a 304-channel low-T{sub c} dc SQUID vector magnetometer, intended to operate in the new Berlin Magnetically Shielded Room (BMSR-2). In order to minimize the space needed to mount the electronics on top of the dewar and to minimize the power consumption, we have integrated four electronics channels on one 3 cm x 10 cm sized board. Furthermore we embedded the analog components of these four channels into a digitally controlled system including an in-system programmable microcontroller. Four of these integrated boards were combined to one module with a size of 4 cm x 4 cm x 16 cm. 19 of these modules were implemented, resulting in a total power consumption of about 61 W. To initialize the 304 channels and to service the system we have developed software tools running on a laptop computer. By means of these software tools the microcontrollers are fed with all required data such as the working points, the characteristic parameters of the sensors (noise, voltage swing), or the sensor position inside of the vector magnetometer system. In this paper, the developed electronics including the software tools are described, and first results are presented.

  17. Magnetic field `flyby' measurement using a smartphone's magnetometer and accelerometer simultaneously

    Science.gov (United States)

    Monteiro, Martín; Stari, Cecilia; Cabeza, Cecilia; Marti, Arturo C.

    2017-12-01

    The spatial dependence of magnetic fields in simple configurations is a common topic in introductory electromagnetism lessons, both in high school and in university courses. In typical experiments, magnetic fields and distances are obtained taking point-by-point values using a Hall sensor and a ruler, respectively. Here, we show how to take advantage of the smartphone capabilities to get simultaneous measures with the built-in accelerometer and magnetometer and to obtain the spatial dependence of magnetic fields. We consider a simple setup consisting of a smartphone mounted on a track whose direction coincides with the axis of a coil. While the smartphone is moving on the track, both the magnetic field and the distance from the center of the coil (integrated numerically from the acceleration values) are simultaneously obtained. This methodology can easily be extended to more complicated setups.

  18. Magnetic dichroism in photoemission: a new element-specific magnetometer with atomic-layer resolution

    International Nuclear Information System (INIS)

    Starke, K.; Arenholz, E.; Kaindl, G.

    1998-01-01

    Full text: Magnetic coupling in layered metallic structures has become a key issue in thin-film magnetism since the observation of oscillatory exchange coupling across non-ferromagnetic spacer layers. Although this phenomenon was discovered in rare earths (RE) superlattices, mostly transition-metal systems have been studied and are now applied in data-storage industry. An understanding of the coupling mechanisms has been reached after a fabrication of high-quality interfaces became possible. It allowed, in particular, the experimental finding of induced ferromagnetic order in 'nonmagnetic' atomic layers near an interface, using element-specific probes such as magnetic circular dichroism in x-ray absorption. - In layered RE systems, by contrast, the well known intermiscibility has prevented a preparation of atomically sharp interfaces, and all RE superlattices studied so far showed interdiffusion zones of several atomic layers. In the present overview, we report the first fabrication of atomically flat heteromagnetic RE interfaces, their structural characterization and their magnetic analysis using magnetic dichroism in photoemission (MDPE). This new tool gives access to the magnetization of individual atomic layers near interfaces in favourite cases. Merits of MDPE as a magnetometer are demonstrated at the example of Eu/Gd(0001), where chemical shifts of core-level photoemission lines allow to spectroscopically separate up to four different atomic layers. The high surface sensitivity of MDPE, together with the well known dependence of the core-level binding energies on the coordination number of the photo emitting atom, opens the door to future site-specific studies of magnetism in sub-monolayer systems such as 'nanowires'

  19. Deconvolution of continuous paleomagnetic data from pass-through magnetometer: A new algorithm to restore geomagnetic and environmental information based on realistic optimization

    Science.gov (United States)

    Oda, Hirokuni; Xuan, Chuang

    2014-10-01

    development of pass-through superconducting rock magnetometers (SRM) has greatly promoted collection of paleomagnetic data from continuous long-core samples. The output of pass-through measurement is smoothed and distorted due to convolution of magnetization with the magnetometer sensor response. Although several studies could restore high-resolution paleomagnetic signal through deconvolution of pass-through measurement, difficulties in accurately measuring the magnetometer sensor response have hindered the application of deconvolution. We acquired reliable sensor response of an SRM at the Oregon State University based on repeated measurements of a precisely fabricated magnetic point source. In addition, we present an improved deconvolution algorithm based on Akaike's Bayesian Information Criterion (ABIC) minimization, incorporating new parameters to account for errors in sample measurement position and length. The new algorithm was tested using synthetic data constructed by convolving "true" paleomagnetic signal containing an "excursion" with the sensor response. Realistic noise was added to the synthetic measurement using Monte Carlo method based on measurement noise distribution acquired from 200 repeated measurements of a u-channel sample. Deconvolution of 1000 synthetic measurements with realistic noise closely resembles the "true" magnetization, and successfully restored fine-scale magnetization variations including the "excursion." Our analyses show that inaccuracy in sample measurement position and length significantly affects deconvolution estimation, and can be resolved using the new deconvolution algorithm. Optimized deconvolution of 20 repeated measurements of a u-channel sample yielded highly consistent deconvolution results and estimates of error in sample measurement position and length, demonstrating the reliability of the new deconvolution algorithm for real pass-through measurements.

  20. A high-performance lab-on-a-chip liquid sensor employing surface acoustic wave resonance

    Science.gov (United States)

    Kustanovich, K.; Yantchev, V.; Kirejev, V.; Jeffries, G. D. M.; Lobovkina, T.; Jesorka, A.

    2017-11-01

    We demonstrate herein a new concept for lab-on-a-chip in-liquid sensing, through integration of surface acoustic wave resonance (SAR) in a one-port configuration with a soft polymer microfluidic delivery system. In this concept, the reflective gratings of a one-port surface acoustic wave (SAW) resonator are employed as mass loading-sensing elements, while the SAW transducer is protected from the measurement environment. We describe the design, fabrication, implementation, and characterization using liquid medium. The sensor operates at a frequency of 185 MHz and has demonstrated a comparable sensitivity to other SAW in-liquid sensors, while offering quality factor (Q) value in water of about 250, low impedance and fairly low susceptibility to viscous damping. For proof of principle, sensing performance was evaluated by means of binding 40 nm neutravidin-coated SiO2 nanoparticles to a biotin-labeled lipid bilayer deposited over the reflectors. Frequency shifts were determined for every step of the affinity assay. Demonstration of this integrated technology highlights the potential of SAR technology for in-liquid sensing.

  1. Electrodynamics of an omega-band as deduced from optical and magnetometer data

    Directory of Open Access Journals (Sweden)

    H. Vanhamäki

    2009-09-01

    Full Text Available We investigate an omega-band event that took place above northern Scandinavia around 02:00–02:30 UT on 9 March 1999. In our analysis we use ground based magnetometer, optical and riometer measurements together with satellite based optical images. The optical and riometer data are used to estimate the ionospheric Hall and Pedersen conductances, while ionospheric equivalent currents are obtained from the magnetometer measurements. These data sets are used as input in a local KRM calculation, which gives the ionospheric potential electric field as output, thus giving us a complete picture of the ionospheric electrodynamic state during the omega-band event. The overall structure of the electric field and field-aligned current (FAC provided by the local KRM method are in good agreement with previous studies. Also the E×B drift velocity calculated from the local KRM solution is in good qualitative agreement with the plasma velocity measured by the Finnish CUTLASS radar, giving further support for the new local KRM method. The high-resolution conductance estimates allow us to discern the detailed structure of the omega-band current system. The highest Hall and Pedersen conductances, ~50 and ~25 S, respectively, are found at the edges of the bright auroral tongue. Inside the tongue, conductances are somewhat smaller, but still significantly higher than typical background values. The electric field shows a converging pattern around the tongues, and the field strength drops from ~40 mV/m found at optically dark regions to ~10 mV/m inside the areas of enhanced conductivity. Downward FAC flow in the dark regions, while upward currents flow inside the auroral tongue. Additionally, sharp conductance gradients at the edge of an auroral tongue are associated with narrow strips of intense FACs, so that a strip of downward current flows at the eastern (leading edge and a similar strip of upward current is present at the western (trailing edge. The Joule

  2. A large-scale view of Space Technology 5 magnetometer response to solar wind drivers.

    Science.gov (United States)

    Knipp, D J; Kilcommons, L M; Gjerloev, J; Redmon, R J; Slavin, J; Le, G

    2015-04-01

    In this data report we discuss reprocessing of the Space Technology 5 (ST5) magnetometer database for inclusion in NASA's Coordinated Data Analysis Web (CDAWeb) virtual observatory. The mission consisted of three spacecraft flying in elliptical orbits, from 27 March to 27 June 2006. Reprocessing includes (1) transforming the data into the Modified Apex Coordinate System for projection to a common reference altitude of 110 km, (2) correcting gain jumps, and (3) validating the results. We display the averaged magnetic perturbations as a keogram, which allows direct comparison of the full-mission data with the solar wind values and geomagnetic indices. With the data referenced to a common altitude, we find the following: (1) Magnetic perturbations that track the passage of corotating interaction regions and high-speed solar wind; (2) unexpectedly strong dayside perturbations during a solstice magnetospheric sawtooth oscillation interval characterized by a radial interplanetary magnetic field (IMF) component that may have enhanced the accompanying modest southward IMF; and (3) intervals of reduced magnetic perturbations or "calms," associated with periods of slow solar wind, interspersed among variable-length episodic enhancements. These calms are most evident when the IMF is northward or projects with a northward component onto the geomagnetic dipole. The reprocessed ST5 data are in very good agreement with magnetic perturbations from the Defense Meteorological Satellite Program (DMSP) spacecraft, which we also map to 110 km. We briefly discuss the methods used to remap the ST5 data and the means of validating the results against DMSP. Our methods form the basis for future intermission comparisons of space-based magnetometer data.

  3. Auto-Calibration Methods of Kinematic Parameters and Magnetometer Offset for the Localization of a Tracked Mobile Robot

    OpenAIRE

    Luciano Cantelli; Samuel Ligama; Giovanni Muscato; Davide Spina

    2016-01-01

    This paper describes an automatic calibration procedure adopted to improve the localization of an outdoor mobile robot. The proposed algorithm estimates, by using an extended Kalman filter, the main kinematic parameters of the vehicles, such as the wheel radii and the wheelbase as well as the magnetometer offset. Several trials have been performed to validate the proposed strategy on a tracked electrical mobile robot. The mobile robot is aimed to be adopted as a tool to help humanitarian demi...

  4. Airborne gamma-ray spectrometer and magnetometer survey, Devils Lake quadrangle, North Dakota. Final report

    International Nuclear Information System (INIS)

    1981-05-01

    During the months of June through October, 1980, Aero Service Division Western Geophysical Company of America conducted an airborne high sensitivity gamma-ray spectrometer and magnetometer survey over eleven (11) 2 0 x 1 0 NTMS quadrangles located in the states of Minnesota and Wisconsin and seven (7) 2 0 x 1 0 NTMS quadrangles in North and South Dakota. This report discusses the results obtained over the Devil's Lake map area of North Dakota. The final data are presented in four different forms: on magnetic tape; on microfiche; in graphic form as profiles and histograms; and in map form as anomaly maps, flight path maps, and computer printer maps

  5. A miniature, low-power scientific fluxgate magnetometer: A stepping-stone to cube-satellite constellation missions

    Science.gov (United States)

    Miles, D. M.; Mann, I. R.; Ciurzynski, M.; Barona, D.; Narod, B. B.; Bennest, J. R.; Pakhotin, I. P.; Kale, A.; Bruner, B.; Nokes, C. D. A.; Cupido, C.; Haluza-DeLay, T.; Elliott, D. G.; Milling, D. K.

    2016-12-01

    Difficulty in making low noise magnetic measurements is a significant challenge to the use of cube-satellite (CubeSat) platforms for scientific constellation class missions to study the magnetosphere. Sufficient resolution is required to resolve three-dimensional spatiotemporal structures of the magnetic field variations accompanying both waves and current systems of the nonuniform plasmas controlling dynamic magnetosphere-ionosphere coupling. This paper describes the design, validation, and test of a flight-ready, miniature, low-mass, low-power, and low-magnetic noise boom-mounted fluxgate magnetometer for CubeSat applications. The miniature instrument achieves a magnetic noise floor of 150-200 pT/√Hz at 1 Hz, consumes 400 mW of power, has a mass of 121 g (sensor and boom), stows on the hull, and deploys on a 60 cm boom from a three-unit CubeSat reducing the noise from the onboard reaction wheel to less than 1.5 nT at the sensor. The instrument's capabilities will be demonstrated and validated in space in late 2016 following the launch of the University of Alberta Ex-Alta 1 CubeSat, part of the QB50 constellation mission. We illustrate the potential scientific returns and utility of using a CubeSats carrying such fluxgate magnetometers to constitute a magnetospheric constellation using example data from the low-Earth orbit European Space Agency Swarm mission. Swarm data reveal significant changes in the spatiotemporal characteristics of the magnetic fields in the coupled magnetosphere-ionosphere system, even when the spacecraft are separated by only approximately 10 s along track and approximately 1.4° in longitude.

  6. Employing Ti nano-powder dielectric to enhance surface characteristics in electrical discharge machining of AISI D2 steel

    Energy Technology Data Exchange (ETDEWEB)

    Marashi, Houriyeh, E-mail: houriyeh@marashi.co [Department of Mechanical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur (Malaysia); Center of Advanced Manufacturing and Materials Processing (AMMP), 50603 Kuala Lumpur (Malaysia); Sarhan, Ahmed A.D., E-mail: ah_sarhan@yahoo.com [Department of Mechanical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur (Malaysia); Center of Advanced Manufacturing and Materials Processing (AMMP), 50603 Kuala Lumpur (Malaysia); Department of Mechanical Engineering, Faculty of Engineering, Assiut University, Assiut 71516 (Egypt); Hamdi, Mohd [Department of Mechanical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur (Malaysia); Center of Advanced Manufacturing and Materials Processing (AMMP), 50603 Kuala Lumpur (Malaysia)

    2015-12-01

    Graphical abstract: - Highlights: • We proposed adding Ti nano-powder to dielectric in EDM. • Average and peak-valley surface roughness was improved by 35 and 40%, respectively. • Improvement of up to 69% in material removal rate was obtained. • Enhanced surface morphology and formation of shallower craters were observed. - Abstract: Manufacturing components with superior surface characteristics is challenging when electrical discharge machining (EDM) is employed for mass production. The aim of this research is to enhance the characteristics of AISI D2 steel surface machined with EDM through adding Ti nano-powder to dielectric under various machining parameters, including discharge duration (T{sub on}) and peak current (I). Surface roughness profilometer, FESEM and AFM analysis were utilized to reveal the machined surface characteristics in terms of surface roughness, surface morphology and surface micro-defects. Moreover, EDX analysis was performed in order to evaluate the atomic deposition of Ti nano-powder on the surface. The concentration of Ti nano-powder in dielectric was also examined using ESEM and EDX. According to the results, the addition of Ti nano-powder to dielectric notably enhanced the surface morphology and surface roughness at all machining parameters except T{sub on} = 340 μs. Of these parameters, maximum enhancement was observed at T{sub on} = 210 μs, where the material removal rate and average surface roughness improved by ∼69 and ∼35% for peak current of 6 and 12 A, respectively. Elemental analysis signified negligible Ti deposition on the machined surface while the atomic concentration of Ti was increased around the crack areas.

  7. Surface crystallization and magnetic properties of amorphous Fe80B20 alloy

    International Nuclear Information System (INIS)

    Vavassori, P.; Ronconi, F.; Puppin, E.

    1997-01-01

    We have studied the effects of surface crystallization on the magnetic properties of Fe 80 B 20 amorphous alloys. The surface magnetic properties have been studied with magneto-optic Kerr measurements, while those of bulk with a vibrating sample magnetometer. This study reveals that surface crystallization is similar to the bulk process but occurs at a lower temperature. At variance with previous results on other iron-based amorphous alloys the surface crystalline layer does not induce bulk magnetic hardening. Furthermore, both the remanence to saturation ratio and the bulk magnetic anisotropy do not show appreciable variations after the formation of the surface crystalline layer. The Curie temperature of the surface layer is lower with respect to the bulk of the sample. These effects can be explained by a lower boron concentration in the surface region of the as-cast amorphous alloy. Measurements of the chemical composition confirm a reduction of boron concentration in the surface region. copyright 1997 American Institute of Physics

  8. Directly coupled direct current superconducting quantum interference device magnetometers based on ramp-edge Ag:YBa2Cu3O7-x/PrBa2Cu3O7-x/Ag:YBa2Cu3O7-x junctions

    International Nuclear Information System (INIS)

    Jia, Q.X.; Yan, F.; Mombourquette, C.; Reagor, D.

    1998-01-01

    Directly coupled dc superconducting quantum interference device (SQUID) magnetometers on LaAlO 3 substrates were fabricated using ramp-edge superconductor/normal-metal/superconductor junctions, where Ag-doped YBa 2 Cu 3 O 7-x was used for the electrode and PrBa 2 Cu 3 O 7-x for the normal-metal barrier. A flux noise of 8x10 -6 Φ 0 Hz -1/2 at 10 kHz measured with a dc bias current was achieved at 75 K, which corresponded to a field sensitivity of 400fTHz -1/2 for a magnetometer with a pick-up loop area of 8.5mmx7.5mm. Most significantly, the noise floor increased at lower frequencies with a frequency dependence slightly less than 1/f. The field noise of the SQUID magnetometers increased by only 25% after cycling the devices from zero field to 500 mG. In a static earth close-quote s magnetic field background, the field noise of the SQUID magnetometers increased by less than a factor of 2. copyright 1998 American Institute of Physics

  9. Auto-Calibration Methods of Kinematic Parameters and Magnetometer Offset for the Localization of a Tracked Mobile Robot

    Directory of Open Access Journals (Sweden)

    Luciano Cantelli

    2016-11-01

    Full Text Available This paper describes an automatic calibration procedure adopted to improve the localization of an outdoor mobile robot. The proposed algorithm estimates, by using an extended Kalman filter, the main kinematic parameters of the vehicles, such as the wheel radii and the wheelbase as well as the magnetometer offset. Several trials have been performed to validate the proposed strategy on a tracked electrical mobile robot. The mobile robot is aimed to be adopted as a tool to help humanitarian demining operations.

  10. Daytime, low latitude, vertical ExB drift velocities, inferred from ground-based magnetometer observations in the Peruvian, Philippine and Indian longitude sectors under quiet and disturbed conditions

    CERN Document Server

    Anderson, D; Chau, J; Yumoto, K; Bhattacharya, A; Alex, S

    2006-01-01

    Daytime, low latitude, vertical ExB drift velocities, inferred from ground-based magnetometer observations in the Peruvian, Philippine and Indian longitude sectors under quiet and disturbed conditions

  11. Feasibility study on measurement of magnetocardiography (MCG) using fluxgate magnetometer

    Science.gov (United States)

    Sengottuvel, S.; Sharma, Akash; Biswal, Deepak; Khan, Pathan Fayaz; Swain, Pragyna Parimita; Patel, Rajesh; Gireesan, K.

    2018-04-01

    This paper reports the feasibility of measuring weak magnetic fields generated by the electrical activity of the heart using a portable tri-axial fluxgate magnetometer inside a magnetically shielded room. Measurement of Magnetocardiogram (MCG) signals could be successfully demonstrated from a healthy subject using a novel set-up involving a reference fluxgate sensor which simultaneously measures the magnetic fields associated with the ECG waveform measured on the same subject. The timing information provided by R wave peaks of ECG recorded by the reference sensor is utilized to generate trigger locked average of the sensor output of the measurement fluxgate, and extract MCG signals in all the three orthogonal directions (X, Y and Z) on the anterior thorax. It is expected that such portable room temperature measurements using fluxgate sensor could assist in validating the direction of the equivalent current dipole associated with the electrical activity of the human heart. This is somewhat difficult in conventional MCG measurements using SQUID sensors, which usually furnish only the z component of the magnetic field and its spatial derivatives.

  12. Real-time Geomagnetic Data from a Raspberry Pi Magnetometer Network in the United Kingdom

    Science.gov (United States)

    Case, N.; Beggan, C.; Marple, S. R.

    2017-12-01

    In 2014, BGS and the University of Lancaster won an STFC Public Engagement grant to build and deploy 10 Raspberry Pi magnetometers to secondary schools across the UK to enable citizen science. The system uses a Raspberry Pi computer as a logging and data transfer device, connected to a set of three orthogonal miniature fluxgate magnetometers. The system has a nominal sensitivity of around 1 nanoTesla (nT), in each component direction (North, East and Down). This is around twenty times less sensitive than a current scientific-level instrument, but given its relatively low-cost, at about £250 ($325) per unit, this is an excellent price-to-performance ratio given we could not improve the sensitivity unless we spent a lot more money. The magnetic data are sampled at a 5 second cadence and sent to the AuroraWatch website at Lancaster University every 2 minutes. The data are freely available to view and download. The primary aim of the project is to encourage students from 14-18 years old to look at how sensors can be used to collect geophysical data and integrate it together to give a wider understanding of physical phenomena. A second aim is to provide useful data on the spatial variation of the magnetic field for analysis of geomagnetic storms, alongside data from the BGS observatory and University of Lancaster's SAMNET variometer network. We show results from the build, testing and running of the sensors including some recent storms and we reflect on our experiences in engaging schools and the general public with information about the magnetic field. The information to build the system and logging and analysis software for the Raspberry Pi is all freely available, allowing those interested to participate in the project as citizen scientists.

  13. A xylophone bar magnetometer for micro/pico satellites

    Science.gov (United States)

    Lamy, Hervé; Niyonzima, Innocent; Rochus, Pierre; Rochus, Véronique

    2010-10-01

    The Belgian Institute of Space Aeronomy (BIRA-IASB), "Centre Spatial de Liège" (CSL), "Laboratoire de Techniques Aéronautiques et Spatiales" (LTAS) of University of Liège, and the Microwave Laboratory of University of Louvain-La-Neuve (UCL) are collaborating in order to develop a miniature version of a xylophone bar magnetometer (XBM) using Microelectromechanical Systems (MEMS) technology. The device is based on a classical resonating xylophone bar. A sinusoidal current is supplied to the bar oscillating at the fundamental transverse resonant mode of the bar. When an external magnetic field is present, the resulting Lorentz force causes the bar to vibrate at its fundamental frequency with an amplitude directly proportional to the vertical component of the ambient magnetic field. In this paper we illustrate the working principles of the XBM and the challenges to reach the required sensitivity in space applications (measuring magnetic fields with an accuracy of approximately of 0.1 nT). The optimal dimensions of the MEMS XBM are discussed as well as the constraints on the current flowing through the bar. Analytical calculations as well as simulations with finite element methods have been used. Prototypes have been built in the Microwave Laboratory using silicon on insulator (SOI) and bulk micromachining processes. Several methods to accurately measure the displacement of the bar are proposed.

  14. A 3-Axis Miniature Magnetic Sensor Based on a Planar Fluxgate Magnetometer with an Orthogonal Fluxguide.

    Science.gov (United States)

    Lu, Chih-Cheng; Huang, Jeff

    2015-06-19

    A new class of tri-axial miniature magnetometer consisting of a planar fluxgate structure with an orthogonal ferromagnetic fluxguide centrally situated over the magnetic cores is presented. The magnetic sensor possesses a cruciform ferromagnetic core placed diagonally upon the square excitation coil under which two pairs of pick-up coils for in-plane field detection are allocated. Effective principles and analysis of the magnetometer for 3-D field vectors are described and verified by numerically electromagnetic simulation for the excitation and magnetization of the ferromagnetic cores. The sensor is operated by applying the second-harmonic detection technique that can verify V-B relationship and device responsivity. Experimental characterization of the miniature fluxgate device demonstrates satisfactory spatial magnetic field detection results in terms of responsivity and noise spectrum. As a result, at an excitation frequency of 50 kHz, a maximum in-plane responsivity of 122.4 V/T appears and a maximum out-of-plane responsivity of 11.6 V/T is obtained as well. The minimum field noise spectra are found to be 0.11 nT/√Hz and 6.29 nT/√Hz, respectively, in X- and Z-axis at 1 Hz under the same excitation frequency. Compared with the previous tri-axis fluxgate devices, this planar magnetic sensor with an orthogonal fluxguide provides beneficial enhancement in both sensory functionality and manufacturing simplicity. More importantly, this novel device concept is considered highly suitable for the extension to a silicon sensor made by the current CMOS-MEMS technologies, thus emphasizing its emerging applications of field detection in portable industrial electronics.

  15. Selective Surface Acoustic Wave-Based Organophosphorus Sensor Employing a Host-Guest Self-Assembly Monolayer of β-Cyclodextrin Derivative

    Directory of Open Access Journals (Sweden)

    Yong Pan

    2015-07-01

    Full Text Available Self-assembly and molecular imprinting technologies are very attractive technologies for the development of artificial recognition systems and provide chemical recognition based on need and not happenstance. In this paper, we employed a b-cyclodextrin derivative surface acoustic wave (SAW chemical sensor for detecting the chemical warfare agents (CWAs sarin (O-Isoprophyl methylphosphonofluoridate, GB. Using sarin acid (isoprophyl hydrogen methylphosphonate as an imprinting template, mono[6-deoxy-6-[(mercaptodecamethylenethio

  16. Low-frequency noise in high-(Tc) superconductor Josephson junctions, SQUIDs, and magnetometers

    Science.gov (United States)

    Miklich, A. H.

    1994-05-01

    Design and performance of high-T(sub c) dc superconducting quantum interference devices (SQUID's), junctions that comprise them, and magnetometers made from them are described, with attention to sources of 1/f noise. Biepitaxial junctions are found to have large levels of critical current fluctuations which make them unsuitable for low-noise SQUID's; this suggests a poorly connected interface at the grain boundary junction. SQUID's from bicrystal junctions have levels of critical current noise controllable using bias current reversal techniques which leave the noise white down to frequencies of a few Hz. A SQUID with an energy resolution of 1.5 x 10(exp -30) J Hz(exp -1) at 1 Hz is reported. Magnetometers in which a (9 mm)(exp 2) pickup loop is directly coupled to a SQUID body have achieved field resolutions of 93 fT Hz(exp -1/2) down to frequencies below 1 Hz, improving to 39 fT Hz(exp -1/2) at 1 Hz with the addition of a 50mm-diameter single-turn flux transformer. Poor coupling to pickup loop makes it difficult to satisfy competing goals of high field resolution and small detector size necessary for multichannel biomagnetic imaging. Improved coupling is demonstrated by the use of multiturn-input-coil flux transformers, and a resolution of 35 fT Hz(exp -1/2) in the white noise region is reported with a (10 mm)(exp 2) pickup loop. However, additional 1/f noise from processed multilayer structures in the transformer limits the resolution at 1 Hz to 114 fT Hz(exp -1/2). High-T(sub c) SQUID's exhibit additional 1/f noise when cooled in a nonzero static magnetic field because of additional flux vortices trapped in the film, with the noise power at 1 Hz typically increasing by a factor of 10-20 in a field of 0.05mT (0.5 G). Finally, a SQUID-based voltmeter with a resolution of 9.2 pV Hz(exp -1/2) at 10 Hz (24 pV Hz(exp -1/2) at 1 Hz) is described.

  17. Low-Frequency Noise in High-T Superconductor Josephson Junctions, Squids, and Magnetometers.

    Science.gov (United States)

    Miklich, Andrew Hostetler

    The design and performance of high-T_ {rm c} dc superconducting quantum interference devices (SQUIDs), the junctions that comprise them, and magnetometers made from them are described, with special attention paid to sources of 1/f noise. Biepitaxial junctions are found to have large levels of critical current fluctuations which make them unsuitable for low-noise SQUIDs. This noise suggests a poorly connected interface at the grain boundary junction. SQUIDs from bicrystal junctions, in contrast, have levels of critical current noise that are controllable using bias current reversal techniques which leave the noise white down to frequencies of a few Hz. A SQUID with an energy resolution of 1.5times 10^{-30} J Hz^ {-1} at 1 Hz is reported. Magnetometers in which a (9 mm)^2 pickup loop is directly coupled to a SQUID body have achieved field resolutions of 93 fT Hz^{-1/2} down to frequencies below 1 Hz, improving to 39 fT Hz^{-1/2} at 1 Hz with the addition of a 50 mm-diameter single-turn flux transformer. Although the performance of these devices is sufficient for single -channel biomagnetometry or geophysical studies, their relatively poor coupling to the pickup loop makes it difficult to satisfy the competing goals of high field resolution and small detector size necessary for multichannel biomagnetic imaging. Improved coupling is demonstrated by the use of multiturn-input-coil flux transformers, and a resolution of 35 fT Hz^{-1/2} in the white noise region is reported with a (10 mm) ^2 pickup loop. However, additional 1/f noise from the processed multilayer structures in the transformer limits the resolution at 1 Hz to 114 fT Hz^ {-1/2}. High-T_{ rm c} SQUIDs are shown to exhibit additional 1/f noise when they are cooled in a nonzero static magnetic field because of the additional flux vortices trapped in the film, with the noise power at 1 Hz typically increasing by a factor of 10-20 in a field of 0.05 mT (0.5 G). Finally, a SQUID-based voltmeter with a resolution

  18. Summary of initial results from the GSFC fluxgate magnetometer on Pioneer 11

    Science.gov (United States)

    Acuna, M. H.; Ness, N. F.

    1975-01-01

    The main magnetic field of Jupiter was measured by the Fluxgate Magnetometer on Pioneer 11 and analysis reveals it to be relatively more complex than expected. In a centered spherical harmonic representation with a maximum order of n = 3 (designated GSFC model 04), the dipole term (with opposite polarity to the Earth's) has a moment of 4.28 Gauss x (Jupiter radius cubed), tilted by 9.6 deg towards a system 111 longitude of 232. The quadrupole and octupole moments are significant, 24% and 21% of the dipole moment respectively, and this leads to deviations of the planetary magnetic field from a simple offset tilted dipole for distances smaller than three Jupiter radii. The GSFC model shows a north polar field strength of 14 Gauss and a south polar field strength of 10.4 Gauss. Enhanced absorption effects in the radiation belts may be predicted as a result of field distortion.

  19. Investigation of a low-cost magneto-inductive magnetometer for space science applications

    Science.gov (United States)

    Regoli, Leonardo H.; Moldwin, Mark B.; Pellioni, Matthew; Bronner, Bret; Hite, Kelsey; Sheinker, Arie; Ponder, Brandon M.

    2018-03-01

    A new sensor for measuring low-amplitude magnetic fields that is ideal for small spacecraft is presented. The novel measurement principle enables the fabrication of a low-cost sensor with low power consumption and with measuring capabilities that are comparable to recent developments for CubeSat applications. The current magnetometer, a software-modified version of a commercial sensor, is capable of detecting fields with amplitudes as low as 8.7 nT at 40 Hz and 2.7 nT at 1 Hz, with a noise floor of 4 pT/Hz at 1 Hz. The sensor has a linear response to less than 3 % over a range of ±100 000 nT. All of these features make the magneto-inductive principle a promising technology for the development of magnetic sensors for both space-borne and ground-based applications to study geomagnetic activity.

  20. Hypervelocity dust particle impacts observed by the Giotto magnetometer and plasma experiments

    Science.gov (United States)

    Neubauer, F. M.; Glassmeier, K.-H.; Coates, A. J.; Goldstein, R.; Acuna, M. H.

    1990-01-01

    This paper describes 13 very short events in the magnetic field of the inner magnetic pile-up region of Comet Halley observed by the Giotto magnetometer experiment together with simultaneous plasma data obtained by the Johnstone plasma analyzer and the ion mass spectrometer experiments. The events are due to dust impacts in the milligram range on the spacecraft at the relative velocity between the cometary dust and the spacecraft of 68 km/sec. They are generally consistent with dust impact events derived from spacecraft attitude perturbations by the Giotto camera. Their characteristic shape generally involves a sudden decrease in magnetic-field magnitude, a subsequent overshoot beyond initial field values, and an asymptotic approach to the initial field (somewhat reminiscent of the magnetic-field signature after the AMPTE releases in the solar wind). These observations give a new way of analyzing ultra-fast dust particles incident on a spacecraft.

  1. Free induction decay MR signal measurements toward ultra-low field MRI with an optically pumped atomic magnetometer.

    Science.gov (United States)

    Oida, Takenori; Kobayashi, Tetsuo

    2013-01-01

    Ultra-low field magnetic resonance imaging (ULF-MRI) has attracted attention because of its low running costs and minimum patient exposure. An optically pumped atomic magnetometer (OPAM) is a magnetic sensor with high sensitivity in the low frequency range, which does not require a cryogenic cooling system. In an effort to develop a ULF-MRI, we attempted to measure the free induction decay MR signals with an OPAM. We successfully detected the MR signals by combining an OPAM and a flux transformer, demonstrating the feasibility of the proposed system.

  2. Natural remanent magnetization and rock magnetic parameters from the North-East Atlantic continental margin : Insights from a new, automated cryogenic magnetometer at the Geological Survey of Norway

    Science.gov (United States)

    Klug, Martin; Fabian, Karl; Knies, Jochen; Sauer, Simone

    2017-04-01

    Natural remanent magnetization (NRM) and rock magnetic parameters from two locations, West Barents Sea ( 71.6°N,16.2°E) and Vestnesa Ridge, NW Svalbard ( 79.0°N, 6.9°E), were acquired using a new, automatically operating cryogenic magnetometer system at the Geological Survey of Norway. The magnetometer setup comprises an automated robot sample feeding, dynamic operation and measurement monitoring, and customised output-to-database data handling. The setup is designed to dynamically enable a variety of parallel measurements with several coupled devices (e.g. balance, MS2B) to effectively use dead-time in between the otherwise time-consuming measurements with the cryogen magnetometer. Web-based access allows remote quality control and interaction 24/7 and enables high sample throughput. The magnetic properties are combined with geophysical, geochemical measurements and optical imaging, both radiographic and colour images, from high-resolution core-logging. The multidisciplinary approach enables determination and interpretation of content and formation of the magnetic fraction, and its development during diagenetic processes. Besides palaeomagnetic age determination the results offer the opportunity to study sediment transformation processes that have implications for the burial and degradation of organic matter. The results also help to understand long and short-term variability of sediment accumulation. Chemical sediment stability is directly linked to environmental and climate variability in the polar marine environment during the recent past.

  3. Comparison between SuperDARN flow vectors and equivalent ionospheric currents from ground magnetometer arrays

    DEFF Research Database (Denmark)

    Weygand, J. M.; Amm, O.; Angelopoulos, V.

    2012-01-01

    seasons. This comparison is done over a range of spatial separations, magnetic latitudes, magnetic local times, and auroral electrojet activity to investigate under what conditions the vectors are anti-parallel to one another. Our results show that in general the equivalent ionospheric currents are anti...... that may influence the alignment include ionospheric conductivity gradients and quiet time backgrounds. Our results can be used to approximate the macroscopic (similar to 1000 km) ionospheric convection patterns. The SECS maps represent a value-added product from the raw magnetometer database and can...... be used for contextual interpretation; they can help with our understanding of magnetosphere-ionosphere coupling mechanisms using ground arrays and the magnetospheric spacecraft data, and they can be used as input for other techniques....

  4. A 3-Axis Miniature Magnetic Sensor Based on a Planar Fluxgate Magnetometer with an Orthogonal Fluxguide

    Directory of Open Access Journals (Sweden)

    Chih-Cheng Lu

    2015-06-01

    Full Text Available A new class of tri-axial miniature magnetometer consisting of a planar fluxgate structure with an orthogonal ferromagnetic fluxguide centrally situated over the magnetic cores is presented. The magnetic sensor possesses a cruciform ferromagnetic core placed diagonally upon the square excitation coil under which two pairs of pick-up coils for in-plane field detection are allocated. Effective principles and analysis of the magnetometer for 3-D field vectors are described and verified by numerically electromagnetic simulation for the excitation and magnetization of the ferromagnetic cores. The sensor is operated by applying the second-harmonic detection technique that can verify V-B relationship and device responsivity. Experimental characterization of the miniature fluxgate device demonstrates satisfactory spatial magnetic field detection results in terms of responsivity and noise spectrum. As a result, at an excitation frequency of 50 kHz, a maximum in-plane responsivity of 122.4 V/T appears and a maximum out-of-plane responsivity of 11.6 V/T is obtained as well. The minimum field noise spectra are found to be 0.11 nT/√Hz and 6.29 nT/√Hz, respectively, in X- and Z-axis at 1 Hz under the same excitation frequency. Compared with the previous tri-axis fluxgate devices, this planar magnetic sensor with an orthogonal fluxguide provides beneficial enhancement in both sensory functionality and manufacturing simplicity. More importantly, this novel device concept is considered highly suitable for the extension to a silicon sensor made by the current CMOS-MEMS technologies, thus emphasizing its emerging applications of field detection in portable industrial electronics.

  5. Nanosatellite High-Precision Magnetic Missions Enabled by Advances in a Stand-Alone Scalar/Vector Absolute Magnetometer

    Science.gov (United States)

    Hulot, G.; Leger, J. M.; Vigneron, P.; Jager, T.; Bertrand, F.; Coisson, P.; Deram, P.; Boness, A.; Tomasini, L.; Faure, B.

    2017-12-01

    Satellites of the ESA Swarm mission currently in operation carry a new generation of Absolute Scalar Magnetometers (ASM), which nominally deliver 1 Hz scalar for calibrating the relative flux gate magnetometers that complete the magnetometry payload (together with star cameras, STR, for attitude restitution) and providing extremely accurate scalar measurements of the magnetic field for science investigations. These ASM instruments, however, can also operate in two additional modes, a high-frequency 250 Hz scalar mode and a 1 Hz absolute dual-purpose scalar/vector mode. The 250 Hz scalar mode already allowed the detection of until now very poorly documented extremely low frequency whistler signals produced by lightning in the atmosphere, while the 1 Hz scalar/vector mode has provided data that, combined with attitude restitution from the STR, could be used to produce scientifically relevant core field and lithospheric field models. Both ASM modes have thus now been fully validated for science applications. Efforts towards developing an improved and miniaturized version of this instrument is now well under way with CNES support in the context of the preparation of a 12U nanosatellite mission (NanoMagSat) proposed to be launched to complement the Swarm satellite constellation. This advanced miniaturized ASM could potentially operate in an even more useful mode, simultaneously providing high frequency (possibly beyond 500 Hz) absolute scalar data and self-calibrated 1 Hz vector data, thus providing scientifically valuable data for multiple science applications. In this presentation, we will illustrate the science such an instrument taken on board a nanosatellite could enable, and report on the current status of the NanoMagSat project that intends to take advantage of it.

  6. Hypervelocity dust particle impacts observed by the Giotto magnetometer and plasma experiments

    International Nuclear Information System (INIS)

    Neubauer, F.M.; Glassmeier, K.H.; Goldstein, R.; Acuna, M.H.; Musmann, G.; Coates, A.J.

    1990-01-01

    The authors report thirteen very short events in the magnetic field of the inner magnetic pile-up region of comet Halley observed by the Giotto magnetometer experiment together with simultaneous plasma data obtained by the Johnstone plasma analyzer and the ion mass spectrometer experiments. The events are due to dust impacts in the milligram range on the spacecraft at the relative velocity between the cometary dust and the spacecraft of 68 km/sec. They are generally consistent with dust impact events derived from spacecraft attitude perturbations by the Giotto camera [Curdt and Keller, private communication]. Their characteristic shape generally involves a sudden decrease in magnetic field magnitude, a subsequent overshoot beyond initial field values and an asymptotic approach to the initial field somewhat reminiscent of the magnetic field signature after the AMPTE releases in the solar wind. These observations give a new way of analyzing ultra-fast dust particles incident on a spacecraft

  7. Optical pumping in a microfabricated Rb vapor cell using a microfabricated Rb discharge light source

    International Nuclear Information System (INIS)

    Venkatraman, V.; Kang, S.; Affolderbach, C.; Mileti, G.; Shea, H.

    2014-01-01

    Miniature ( 3 ) vapor-cell based devices using optical pumping of alkali atoms, such as atomic clocks and magnetometers, today mostly employ vertical-cavity surface-emitting lasers as pump light sources. Here, we report on the demonstration of optical pumping in a microfabricated alkali vapor resonance cell using (1) a microfabricated Rb discharge lamp light source, as well as (2) a conventional glass-blown Rb discharge lamp. The microfabricated Rb lamp cell is a dielectric barrier discharge (DBD) light source, having the same inner cell volume of around 40 mm 3 as that of the resonance cell, both filled with suitable buffer gases. A miniature (∼2 cm 3 volume) test setup based on the M z magnetometer interrogation technique was used for observation of optical-radiofrequency double-resonance signals, proving the suitability of the microfabricated discharge lamp to introduce efficient optical pumping. The pumping ability of this light source was found to be comparable to or even better than that of a conventional glass-blown lamp. The reported results indicate that the micro-fabricated DBD discharge lamp has a high potential for the development of a new class of miniature atomic clocks, magnetometers, and quantum sensors

  8. Sticky Bomb Detection With Other Implications For Vehicle Security

    Science.gov (United States)

    2010-04-15

    performance of two commercial magnetometers . The first was a handheld Walker Scientific Triaxial FluxGate Magnetometer with a 1 nanoTesla (nT) resolution...along each of 3 axes. The other ! !!!!!!!!!!!!!!!!!!!!!!!!!"#$%&’(!#)!*+,-./’(!01/$%.2,!34567!89:39!4;ɝɞ! ! 38! magnetometer was a PNI V2XE 2-axis...Argonne, IL is approximately 45,000 nT at the surface.) Readings from the Walker magnetometer were recorded manually from the liquid crystal

  9. Localization of firearm projectiles in the human body using a superconducting quantum interference device magnetometer: A theoretical study

    Science.gov (United States)

    Hall Barbosa, C.

    2004-06-01

    A technique had been previously developed, based on magnetic field measurements using a superconducting quantum interference device sensor, to localize in three dimensions steel needles lost in the human body. In all six cases that were treated until now, the technique allowed easy surgical localization of the needles with high accuracy. The technique decreases, by a large factor, the surgery time for foreign body extraction, and also reduces the generally high odds of failure. The method is accurate, noninvasive, and innocuous, and with clear clinical importance. Despite the importance of needle localization, the most prevalent foreign body in the modern society is the firearm projectile (bullet), generally composed of lead, a paramagnetic material, thus not presenting a remanent magnetic field as steel needles do. On the other hand, since lead is a good conductor, eddy current detection techniques can be employed, by applying an alternating magnetic field with the aid of excitation coils. The primary field induces eddy currents on the lead, which in turn generate a secondary magnetic field that can be detected by a magnetometer, and give information about position and volume of the conducting foreign body. In this article we present a theoretical study for the development of a localization technique for lead bullets inside the human body. Initially, we present a model for the secondary magnetic field generated by the bullet, given a known applied field. After that, we study possible excitation systems, and propose a localization algorithm based on the detected magnetic field.

  10. Lunar magnetic anomalies detected by the Apollo substatellite magnetometers

    Science.gov (United States)

    Hood, L.L.; Coleman, P.J.; Russell, C.T.; Wilhelms, D.E.

    1979-01-01

    Properties of lunar crustal magnetization thus far deduced from Apollo subsatellite magnetometer data are reviewed using two of the most accurate presently available magnetic anomaly maps - one covering a portion of the lunar near side and the other a part of the far side. The largest single anomaly found within the region of coverage on the near-side map correlates exactly with a conspicuous, light-colored marking in western Oceanus Procellarum called Reiner Gamma. This feature is interpreted as an unusual deposit of ejecta from secondary craters of the large nearby primary impact crater Cavalerius. An age for Cavalerius (and, by implication, for Reiner Gamma) of 3.2 ?? 0.2 ?? 109 y is estimated. The main (30 ?? 60 km) Reiner Gamma deposit is nearly uniformly magnetized in a single direction, with a minimum mean magnetization intensity of ???7 ?? 10-2 G cm3/g (assuming a density of 3 g/cm3), or about 700 times the stable magnetization component of the most magnetic returned samples. Additional medium-amplitude anomalies exist over the Fra Mauro Formation (Imbrium basin ejecta emplaced ???3.9 ?? 109 y ago) where it has not been flooded by mare basalt flows, but are nearly absent over the maria and over the craters Copernicus, Kepler, and Reiner and their encircling ejecta mantles. The mean altitude of the far-side anomaly gap is much higher than that of the near-side map and the surface geology is more complex, so individual anomaly sources have not yet been identified. However, it is clear that a concentration of especially strong sources exists in the vicinity of the craters Van de Graaff and Aitken. Numerical modeling of the associated fields reveals that the source locations do not correspond with the larger primary impact craters of the region and, by analogy with Reiner Gamma, may be less conspicuous secondary crater ejecta deposits. The reason for a special concentration of strong sources in the Van de Graaff-Aitken region is unknown, but may be indirectly

  11. Improved molecular fingerprint analysis employing multi-branched gold nanoparticles in conjunction with surface-enhanced Raman scattering

    Directory of Open Access Journals (Sweden)

    Johnston J

    2015-12-01

    Full Text Available Jencilin Johnston,1 Erik N Taylor,1,2 Richard J Gilbert,2 Thomas J Webster1,3 1Department of Chemical Engineering, 2Department of Chemistry and Chemical Biology, Northeastern University, Boston, MA, USA; 3Center of Excellence for Advanced Materials Research, King Abdulaziz University, Jeddah, Saudi Arabia Abstract: Vibrational spectroscopy is a powerful analytical tool that assesses molecular properties based on spectroscopic signatures. In this study, the effect of gold nanoparticle morphology (spherical vs multi-branched was assessed for the characterization of a Raman signal (ie, molecular fingerprint that may be helpful for numerous medical applications. Multi-branched gold nanoparticles (MBAuNPs were fabricated using a green chemistry method which employed the reduction of gold ion solute by 2-[4-(2-hydroxyethyl-1-piperazyl] ethane sulfonic acid. Two types of reporter dyes, indocyanine (IR820 and IR792 and carbocyanine (DTTC [3,3'-diethylthiatricarbocyanine iodide] and DTDC [3,3'-diethylthiadicarbocyanine iodide], were functionalized to the surface of the MBAuNPs and stabilized with denatured bovine serum albumin, thus forming the surface-enhanced Raman spectroscopy tag. Fluorescein isothiocyanate-conjugated anti-epidermal growth factor receptor to the surface-enhanced Raman spectroscopy tags and the properties of the resulting conjugates were assessed through determination of the Raman signal. Using the MBAuNP Raman probes synthesized in this manner, we demonstrated that MBAuNP provided significantly more surface-enhanced Raman scattering signal when compared with the associated spherical gold nanoparticle of similar size and concentration. MBAuNP enhancements were retained in the surface-enhanced Raman spectroscopy tags complexed to anti-epidermal growth factor receptor, providing evidence that this could be a useful biological probe for enhanced Raman molecular fingerprinting. Furthermore, while utilizing IR820 as a novel reporter dye

  12. Magnetic measurements with fluxgate 3-components magnetometers in archaeology. Multi-sensor device and associated potential field operators for large scale to centimetre investigations on the 1st millennium BC site of Qasr ʿAllam in the western desert of

    Science.gov (United States)

    Gavazzi, Bruno; Alkhatib-Alkontar, Rozan; Munschy, Marc; Colin, Frédéric; Duvette, Catherine

    2016-04-01

    Fluxgate 3-components magnetometers allow vector measurements of the magnetic field. Moreover, they are the magnetometers measuring the intensity of the magnetic field with the lightest weight and the lowest power consumption. Vector measurements make them the only kind of magnetometer allowing compensation of magnetic perturbations due to the equipment carried with the magnetometer. Fluxgate 3-components magnetometers are common in space magnetometry and in aero-geophysics but are never used in archaeology due to the difficulty to calibrate them. This problem is overcome by the use of a simple calibration and compensation procedure on the field developed initially for space research (after calibration and compensation, rms noise is less than 1 nT). It is therefore possible to build a multi-sensor (up to 8) and georeferenced device for investigations at different scales down to the centimetre: because the locus of magnetic measurements is less than a cubic centimetre, magnetic profiling or mapping can be performed a few centimetres outside magnetized bodies. Such an equipment is used in a context of heavy sediment coverage and uneven topography on the 1st millennium BC site of Qasr ʿAllam in the western desert of Egypt. Magnetic measurements with a line spacing of 0.5 m allow to compute a magnetic grid. Interpretation using potential field operators such as double reduction to the pole and fractional vertical derivatives reveals a widespread irrigation system and a vast cultic facility. In some areas, magnetic profiling with a 0.1 m line spacing and at 0.1 m above the ground is performed. Results of interpretations give enough proof to the local authorities to enlarge the protection of the site against the threatening progression of agricultural fields.

  13. Mapping plasma structures in the high-latitude ionosphere using beacon satellite, incoherent scatter radar and ground-based magnetometer observations

    Directory of Open Access Journals (Sweden)

    T. Neubert

    2002-06-01

    Full Text Available In the autumn of the year 2000, four radio receivers capable of tracking various beacon satellites were set up along the southwestern coast of Greenland. They are used to reconstruct images of the ionospheric plasma density distribution via the tomographic method. In order to test and validate tomographic imaging under the highly variable conditions often prevailing in the high-latitude ionosphere, a time interval was selected when the Sondrestrom incoherent scatter radar conducted measurements of the ionospheric plasma density while the radio receivers tracked a number of beacon satellites. A comparison between two-dimensional images of the plasma density distribution obtained from the radar and the satellite receivers revealed generally good agreement between radar measurements and tomographic images. Observed discrepancies can be attributed to F region plasma patches moving through the field of view with a speed of several hundred meters per second, thereby smearing out the tomographic image. A notable mismatch occurred around local magnetic midnight when a magnetospheric substorm breakup occurred in the vicinity of southwest Greenland (identified from ground-based magnetometer observations. The breakup was associated with a sudden intensification of the westward auroral electrojet which was centered at about 69 and extended up to some 73 corrected geomagnetic latitude. Ground-based magnetometer data may thus have the potential of indicating when the tomographic method is at risk and may fail. We finally outline the application of tomographic imaging, when combined with magnetic field data, to estimate ionospheric Joule heating rates.

  14. CLUSTER STAFF search coils magnetometer calibration - comparisons with FGM

    Science.gov (United States)

    Robert, P.; Cornilleau-Wehrlin, N.; Piberne, R.; de Conchy, Y.; Lacombe, C.; Bouzid, V.; Grison, B.; Alison, D.; Canu, P.

    2013-12-01

    The main part of Cluster Spatio Temporal Analysis of Field Fluctuations (STAFF) experiment consists of triaxial search coils allowing the measurements of the three magnetic components of the waves from 0.1 Hz up to 4 kHz. Two sets of data are produced, one by a module to filter and transmit the corresponding waveform up to either 10 or 180 Hz (STAFF-SC) and the second by an onboard Spectrum Analyser (STAFF-SA) to compute the elements of the spectral matrix for five components of the waves, 3 × B and 2 × E (from EFW experiment) in the frequency range 8 Hz to 4 kHz. In order to understand the way the output signal of the search coils are calibrated, the transfer functions of the different parts of the instrument are described as well as the way to transform telemetry data into physical units, across various coordinate systems from the spinning sensors to a fixed and known frame. The instrument sensitivity is discussed. Cross-calibration inside STAFF (SC and SA) is presented. Results of cross-calibration between the STAFF search coils and the Cluster Flux Gate Magnetometer (FGM) data are discussed. It is shown that these cross-calibrations lead to an agreement between both data sets at low frequency within a 2% error. By means of statistics done over 10 yr, it is shown that the functionalities and characteristics of both instruments have not changed during this period.

  15. CLUSTER-STAFF search coil magnetometer calibration - comparisons with FGM

    Science.gov (United States)

    Robert, P.; Cornilleau-Wehrlin, N.; Piberne, R.; de Conchy, Y.; Lacombe, C.; Bouzid, V.; Grison, B.; Alison, D.; Canu, P.

    2014-09-01

    The main part of the Cluster Spatio-Temporal Analysis of Field Fluctuations (STAFF) experiment consists of triaxial search coils allowing the measurements of the three magnetic components of the waves from 0.1 Hz up to 4 kHz. Two sets of data are produced, one by a module to filter and transmit the corresponding waveform up to either 10 or 180 Hz (STAFF-SC), and the second by the onboard Spectrum Analyser (STAFF-SA) to compute the elements of the spectral matrix for five components of the waves, 3 × B and 2 × E (from the EFW experiment), in the frequency range 8 Hz to 4 kHz. In order to understand the way the output signals of the search coils are calibrated, the transfer functions of the different parts of the instrument are described as well as the way to transform telemetry data into physical units across various coordinate systems from the spinning sensors to a fixed and known frame. The instrument sensitivity is discussed. Cross-calibration inside STAFF (SC and SA) is presented. Results of cross-calibration between the STAFF search coils and the Cluster Fluxgate Magnetometer (FGM) data are discussed. It is shown that these cross-calibrations lead to an agreement between both data sets at low frequency within a 2% error. By means of statistics done over 10 yr, it is shown that the functionalities and characteristics of both instruments have not changed during this period.

  16. Investigation of a low-cost magneto-inductive magnetometer for space science applications

    Directory of Open Access Journals (Sweden)

    L. H. Regoli

    2018-03-01

    Full Text Available A new sensor for measuring low-amplitude magnetic fields that is ideal for small spacecraft is presented. The novel measurement principle enables the fabrication of a low-cost sensor with low power consumption and with measuring capabilities that are comparable to recent developments for CubeSat applications. The current magnetometer, a software-modified version of a commercial sensor, is capable of detecting fields with amplitudes as low as 8.7 nT at 40 Hz and 2.7 nT at 1 Hz, with a noise floor of 4 pT∕Hz at 1 Hz. The sensor has a linear response to less than 3 % over a range of ±100 000 nT. All of these features make the magneto-inductive principle a promising technology for the development of magnetic sensors for both space-borne and ground-based applications to study geomagnetic activity.

  17. Remote sensing the plasmasphere, plasmapause, plumes and other features using ground-based magnetometers

    Directory of Open Access Journals (Sweden)

    Menk Frederick

    2014-01-01

    Full Text Available The plasmapause is a highly dynamic boundary between different magnetospheric particle populations and convection regimes. Some of the most important space weather processes involve wave-particle interactions in this region, but wave properties may also be used to remote sense the plasmasphere and plasmapause, contributing to plasmasphere models. This paper discusses the use of existing ground magnetometer arrays for such remote sensing. Using case studies we illustrate measurement of plasmapause location, shape and movement during storms; refilling of flux tubes within and outside the plasmasphere; storm-time increase in heavy ion concentration near the plasmapause; and detection and mapping of density irregularities near the plasmapause, including drainage plumes, biteouts and bulges. We also use a 2D MHD model of wave propagation through the magnetosphere, incorporating a realistic ionosphere boundary and Alfvén speed profile, to simulate ground array observations of power and cross-phase spectra, hence confirming the signatures of plumes and other density structures.

  18. A survey of flux transfer events recorded by the UKS spacecraft magnetometer

    International Nuclear Information System (INIS)

    Southwood, D.J.; Saunders, M.A.; Dunlop, M.W.; Mier-Jedrzejowicz, W.A.C.; Rijnbeek, R.P.

    1986-01-01

    The UKS spacecraft operated from August 1984 through to January 1985. During that time, it made multiple crossings of the magnetopause in local time sectors extending from mid-afternoon to just behind the dawn meridian. We have surveyed the magnetometer records from these magnetopause encounters and have compiled a catalogue of flux transfer events. Using the catalogue, we find the FTE occurrence determined from the UKS data set is substantially less than that detected using data from the early ISEE 1/2 spacecraft orbits. The UKS data set shows a correlation between FTE occurrence and southward external magnetic field, but there are several instances of passes in which no FTEs are detected but for which the external field was unambiguously southward. The passes with the largest number of events are those for which the field outside the magnetopause has a large Bsub(M) component. We conclude that the lower latitude of the UKS encounters is responsible for the discrepancy with the ISEE occurrence. The most likely source region appears to be near the subsolar region. (author)

  19. Airborne gamma-ray spectrometer and magnetometer survey Coos Bay, Oregon. Final report

    International Nuclear Information System (INIS)

    1981-05-01

    During the months of August, September, and October of 1980, Aero Service Division Western Geophysical Company of America conducted an airborne high sensitivity gamma-ray spectrometer and magnetometer survey over ten (10) areas over northern California and southwestern Oregon. These include the 2 0 x 1 0 NTMS quadrangles of Roseburg, Medford, Weed, Alturas, Redding, Susanville, Ukiah, and Chico along with the 1 0 x 2 0 areas of the Coos Bay quadrangle and the Crescent City/Eureka areas combined. This report discusses the results obtained over the Coos Bay, Oregon, map area. Line spacing was generally six miles for east/west traverses and eighteen miles for north/south tie lines over the northern one-half of the area. Traverses and tie lines were flown at three miles and twelve miles respectively over the southern one-half of the area. A total of 16,880.5 line miles of geophysical data were acquired, compiled, and interpreted during the survey, of which 863.8 line miles are in this quadrangle

  20. Airborne gamma-ray spectrometer and magnetometer survey: Alturas quadrangle, California. Final report

    International Nuclear Information System (INIS)

    1981-05-01

    An airborne high sensitivity gamma-ray spectrometer and magnetometer survey was conducted over ten (10) areas over northern California and southwestern Oregon. These include the 2 0 x 1 0 NTMS quadrangles of Roseburg, Medford, Weed, Alturas, Redding, Susanville, Ukiah, and Chico along with the 1 0 x 2 0 areas of the Coos Bay quadrangle and the Crescent City/Eureka areas combined. This report discusses the results obtained over the Alturas, California, map area. Traverse lines were flown in an east-west direction at a line spacing of six (6) miles. Tie lines were flown north-south approximately eighteen (18) miles apart. A total of 16,880.5 line miles of geophysical data were acquired, compiled, and interpreted during the survey, of which 1631.6 line miles are in this quadrangle. The purpose of this study is to acquire and compile geologic and other information with which to assess the magnitude and distribution of uranium resources and to determine areas favorable for the occurrence of uranium in the United States

  1. Airborne gamma-ray spectrometer and magnetometer survey: Susanville quadrangle, California. Final report

    International Nuclear Information System (INIS)

    1981-05-01

    An airborne high sensitivity gamma-ray spectrometer and magnetometer survey was conducted over ten (10) areas over northern California and southwestern Oregon. These include the 2 0 x 1 0 NTMS quadrangles of Roseburg, Medford, Weed, Alturas, Redding, Susanville, Ukiah, and Chico along with the 1 0 x 2 0 areas of the Coos Bay quadrangle and the Crescent City/Eureka areas combined. This report discusses the results obtained over the Susanville, California, map area. Traverse lines were flown in an east-west direction at a line spacing of six (6) miles. Tie lines were flown north-south approximately eighteen (18) miles apart. A total of 16,880.5 line miles of geophysical data were acquired, compiled, and interpreted during the survey, of which 1642.8 line miles are in this quadrangle. The purpose of this study is to acquire and compile geologic and other information with which to assess the magnitude and distribution of uranium resources and to determine areas favorable for the occurrence of uranium in the United States

  2. DESIGN AND CALIBRATION OF A VIBRANT SAMPLE MAGNETOMETER: CHARACTERIZATION OF MAGNETIC MATERIALS

    Directory of Open Access Journals (Sweden)

    Freddy P. Guachun

    2018-01-01

    Full Text Available This paper presents the process followed in the implementation of a vibrating sample magnetometer (VSM, constructed with materials commonly found in an electromagnetism laboratory. It describes the design, construction, calibration and use in the characterization of some magnetic materials. A VSM measures the magnetic moment of a sample when it is vibrated perpendicular to a uniform magnetic field; Magnetization and magnetic susceptibility can be determined from these readings. This instrument stands out for its simplicity, versatility and low cost, but it is very sensitive and capable of eliminating or minimizing many sources of error that are found in other methods of measurement, allowing to obtain very accurate and reliable results. Its operation is based on the law of magnetic induction of Lenz-Faraday that consists in measuring the induced voltage in coils of detection produced by the variation of the magnetic flux that crosses them. The calibration of the VSM was performed by means of a standard sample (Magnetite and verified by means of a test sample (Nickel.

  3. In-Flight Calibration of the MMS Fluxgate Magnetometers

    Science.gov (United States)

    Bromund, K. R.; Plaschke, F.; Strangeway, R. J.; Anderson, B. J.; Huang, B. G.; Magnes, W.; Fischer, D.; Nakamura, R.; Leinweber, H. K.; Russell, C. T.; hide

    2017-01-01

    We present an overview of the approach to in-flight calibration, which is a coordinated effort between the University of California Los Angeles (UCLA), Space Research Institute, Graz, Austria (IWF) and the NASA Goddard Space Flight Center (GSFC). We present details of the calibration effort at GSFC. During the first dayside season of the Magnetospheric Multiscale (MMS) mission, the in-flight calibration process for the Fluxgate magnetometers (FGM) implemented an algorithm that selected a constant offset (zero-level) for each sensor on each orbit. This method was generally able to reduce the amplitude of residual spin tone to less than 0.2 nT within the region of interest. However, there are times when the offsets do show significant short-term variations. These variations are most prominent in the nighttime season (phase 1X), when eclipses are accompanied by offset changes as large as 1 nT. Eclipses are followed by a recovery period as long as 12 hours where the offsets continue to change as temperatures stabilize. Understanding and compensating for these changes will become critical during Phase 2 of the mission in 2017, when the nightside will become the focus of MMS science. Although there is no direct correlation between offset and temperature, the offsets are seen for the period of any given week to be well-characterized as function of instrument temperature. Using this property, a new calibration method has been developed that has proven effective in compensating for temperature-dependent offsets during phase 1X of the MMS mission and also promises to further refine calibration quality during the dayside season.

  4. Magnetism and the interior of the moon. [measured at Apollo landing sites

    Science.gov (United States)

    Dyal, P.; Parkin, C. W.; Daily, W. D.

    1974-01-01

    During the time period 1961-1972 eleven magnetometers were sent to the moon. The results of lunar magnetometer data analysis are reviewed, with emphasis on the lunar interior. Magnetic fields have been measured on the lunar surface at the Apollo 12, 14, 15, and 16 landing sites. The remanent field values at these sites are given. Satellite and surface measurements show strong evidence that the lunar crust is magnetized over much of the lunar globe. The origin of the lunar remanent field is not yet satisfactorily understood; several source models are presented. Simultaneous data from the Apollo 12 lunar surface magnetometer and the Explorer 35 Ames magnetometer are used to construct a wholemoon hysteresis curve, from which the global lunar permeability is determined. Total iron abundance is calculated for two assumed compositional models of the lunar interior. Other lunar models with a small iron core and with a shallow iron-rich layer are also discussed in light of the measured global permeability.

  5. Reducing systematic errors in measurements made by a SQUID magnetometer

    International Nuclear Information System (INIS)

    Kiss, L.F.; Kaptás, D.; Balogh, J.

    2014-01-01

    A simple method is described which reduces those systematic errors of a superconducting quantum interference device (SQUID) magnetometer that arise from possible radial displacements of the sample in the second-order gradiometer superconducting pickup coil. By rotating the sample rod (and hence the sample) around its axis into a position where the best fit is obtained to the output voltage of the SQUID as the sample is moved through the pickup coil, the accuracy of measuring magnetic moments can be increased significantly. In the cases of an examined Co 1.9 Fe 1.1 Si Heusler alloy, pure iron and nickel samples, the accuracy could be increased over the value given in the specification of the device. The suggested method is only meaningful if the measurement uncertainty is dominated by systematic errors – radial displacement in particular – and not by instrumental or environmental noise. - Highlights: • A simple method is described which reduces systematic errors of a SQUID. • The errors arise from a radial displacement of the sample in the gradiometer coil. • The procedure is to rotate the sample rod (with the sample) around its axis. • The best fit to the SQUID voltage has to be attained moving the sample through the coil. • The accuracy of measuring magnetic moment can be increased significantly

  6. Optical pumping in a microfabricated Rb vapor cell using a microfabricated Rb discharge light source

    Energy Technology Data Exchange (ETDEWEB)

    Venkatraman, V.; Kang, S.; Affolderbach, C.; Mileti, G., E-mail: gaetano.mileti@unine.ch [Laboratoire Temps-Fréquence, University of Neuchâtel, Neuchâtel 2000 (Switzerland); Shea, H. [Microsystems for Space Technologies Laboratory, Ecole Polytechnique Fédérale de Lausanne (EPFL), Neuchâtel 2002 (Switzerland)

    2014-02-03

    Miniature (magnetometers, today mostly employ vertical-cavity surface-emitting lasers as pump light sources. Here, we report on the demonstration of optical pumping in a microfabricated alkali vapor resonance cell using (1) a microfabricated Rb discharge lamp light source, as well as (2) a conventional glass-blown Rb discharge lamp. The microfabricated Rb lamp cell is a dielectric barrier discharge (DBD) light source, having the same inner cell volume of around 40 mm{sup 3} as that of the resonance cell, both filled with suitable buffer gases. A miniature (∼2 cm{sup 3} volume) test setup based on the M{sub z} magnetometer interrogation technique was used for observation of optical-radiofrequency double-resonance signals, proving the suitability of the microfabricated discharge lamp to introduce efficient optical pumping. The pumping ability of this light source was found to be comparable to or even better than that of a conventional glass-blown lamp. The reported results indicate that the micro-fabricated DBD discharge lamp has a high potential for the development of a new class of miniature atomic clocks, magnetometers, and quantum sensors.

  7. A Bistable Microelectronic Circuit for Sensing Extremely Low Electric Field

    Science.gov (United States)

    2010-01-01

    potential system describing the ferromagnetic ma- terials employed in the fluxgate magnetometers .1 To give a clearer picture of the separations between...this behavior in a specific prototype system comprised of three unidirectionally coupled ferromagnetic cores, the basis of a coupled core fluxgate ... magnetometer . Another prototypical quartic poten- tial based system of coupled overdamped Duffing elements has been applied to describe the dynamics

  8. Detection of Target ssDNA Using a Microfabricated Hall Magnetometer with Correlated Optical Readout

    Directory of Open Access Journals (Sweden)

    Steven M. Hira

    2012-01-01

    Full Text Available Sensing biological agents at the genomic level, while enhancing the response time for biodetection over commonly used, optics-based techniques such as nucleic acid microarrays or enzyme-linked immunosorbent assays (ELISAs, is an important criterion for new biosensors. Here, we describe the successful detection of a 35-base, single-strand nucleic acid target by Hall-based magnetic transduction as a mimic for pathogenic DNA target detection. The detection platform has low background, large signal amplification following target binding and can discriminate a single, 350 nm superparamagnetic bead labeled with DNA. Detection of the target sequence was demonstrated at 364 pM (<2 target DNA strands per bead target DNA in the presence of 36 μM nontarget (noncomplementary DNA (<10 ppm target DNA using optical microscopy detection on a GaAs Hall mimic. The use of Hall magnetometers as magnetic transduction biosensors holds promise for multiplexing applications that can greatly improve point-of-care (POC diagnostics and subsequent medical care.

  9. Infrastructure-Less Indoor Localization Using the Microphone, Magnetometer and Light Sensor of a Smartphone

    Directory of Open Access Journals (Sweden)

    Carlos E. Galván-Tejada

    2015-08-01

    Full Text Available In this paper, we present the development of an infrastructure-less indoor location system (ILS, which relies on the use of a microphone, a magnetometer and a light sensor of a smartphone, all three of which are essentially passive sensors, relying on signals available practically in any building in the world, no matter how developed the region is. In our work, we merge the information from those sensors to estimate the user’s location in an indoor environment. A multivariate model is applied to find the user’s location, and we evaluate the quality of the resulting model in terms of sensitivity and specificity. Our experiments were carried out in an office environment during summer and winter, to take into account changes in light patterns, as well as changes in the Earth’s magnetic field irregularities. The experimental results clearly show the benefits of using the information fusion of multiple sensors when contrasted with the use of a single source of information.

  10. Infrastructure-Less Indoor Localization Using the Microphone, Magnetometer and Light Sensor of a Smartphone.

    Science.gov (United States)

    Galván-Tejada, Carlos E; García-Vázquez, Juan Pablo; Galván-Tejada, Jorge I; Delgado-Contreras, J Rubén; Brena, Ramon F

    2015-08-18

    In this paper, we present the development of an infrastructure-less indoor location system (ILS), which relies on the use of a microphone, a magnetometer and a light sensor of a smartphone, all three of which are essentially passive sensors, relying on signals available practically in any building in the world, no matter how developed the region is. In our work, we merge the information from those sensors to estimate the user's location in an indoor environment. A multivariate model is applied to find the user's location, and we evaluate the quality of the resulting model in terms of sensitivity and specificity. Our experiments were carried out in an office environment during summer and winter, to take into account changes in light patterns, as well as changes in the Earth's magnetic field irregularities. The experimental results clearly show the benefits of using the information fusion of multiple sensors when contrasted with the use of a single source of information.

  11. Optimization of a digital SQUID magnetometer in terms of noise and distortion

    International Nuclear Information System (INIS)

    Haverkamp, I; Toepfer, H; Wetzstein, O; Kunert, J; Stolz, R; Meyer, H-G; Ortlepp, T

    2012-01-01

    The digital SQUID magnetometer takes advantage of flux quantization in a superconducting loop in order to measure magnetic fields. The core element of the digital SQUID is a Josephson comparator with a superconducting antenna loop attached to one of its junctions. Evaluation of the circuit from the system’s point of view requires an analysis in the frequency domain. In order to obtain a high-resolution fast Fourier transform, large datasets are necessary which are difficult to generate with transient simulation tools. In this work we derive a behavioural model for the digital SQUID in order to overcome restrictions imposed by transient simulation. By means of this model the influence of the comparator grey zone and the input loop inductance on the system performance was analysed. In order to assess the system, evaluation criteria based on the power spectral density were applied, which are commonly used for characterization of semiconductor analogue to digital converters. As a result of this study, design guidelines for an optimum antenna inductance depending on the comparator grey zone are derived, allowing us to achieve an optimum system performance in terms of noise and distortion. (paper)

  12. Flux-gate magnetometer spin axis offset calibration using the electron drift instrument

    International Nuclear Information System (INIS)

    Plaschke, Ferdinand; Nakamura, Rumi; Baumjohann, Wolfgang; Steller, Manfred; Magnes, Werner; Leinweber, Hannes K; Chutter, Mark; Vaith, Hans

    2014-01-01

    Spin-stabilization of spacecraft immensely supports the in-flight calibration of on-board flux-gate magnetometers (FGMs). From 12 calibration parameters in total, 8 can be easily obtained by spectral analysis. From the remaining 4, the spin axis offset is known to be particularly variable. It is usually determined by analysis of Alfvénic fluctuations that are embedded in the solar wind. In the absence of solar wind observations, the spin axis offset may be obtained by comparison of FGM and electron drift instrument (EDI) measurements. The aim of our study is to develop methods that are readily usable for routine FGM spin axis offset calibration with EDI. This paper represents a major step forward in this direction. We improve an existing method to determine FGM spin axis offsets from EDI time-of-flight measurements by providing it with a comprehensive error analysis. In addition, we introduce a new, complementary method that uses EDI beam direction data instead of time-of-flight data. Using Cluster data, we show that both methods yield similarly accurate results, which are comparable yet more stable than those from a commonly used solar wind-based method. (paper)

  13. An ultra-sensitive and wideband magnetometer based on a superconducting quantum interference device

    Science.gov (United States)

    Storm, Jan-Hendrik; Hömmen, Peter; Drung, Dietmar; Körber, Rainer

    2017-02-01

    The magnetic field noise in superconducting quantum interference devices (SQUIDs) used for biomagnetic research such as magnetoencephalography or ultra-low-field nuclear magnetic resonance is usually limited by instrumental dewar noise. We constructed a wideband, ultra-low noise system with a 45 mm diameter superconducting pick-up coil inductively coupled to a current sensor SQUID. Thermal noise in the liquid helium dewar is minimized by using aluminized polyester fabric as superinsulation and aluminum oxide strips as heat shields. With a magnetometer pick-up coil in the center of the Berlin magnetically shielded room 2 (BMSR2), a noise level of around 150 aT Hz-1/2 is achieved in the white noise regime between about 20 kHz and the system bandwidth of about 2.5 MHz. At lower frequencies, the resolution is limited by magnetic field noise arising from the walls of the shielded room. Modeling the BMSR2 as a closed cube with continuous μ-metal walls, we can quantitatively reproduce its measured field noise.

  14. Airborne gamma-ray spectrometer and magnetometer survey, Mitchell Quadrangle, South Dakota. Final report

    International Nuclear Information System (INIS)

    1981-04-01

    An airborne high sensitivity gamma-ray spectrometer and magnetometer survey was conducted over eleven (11) 2 0 x 1 0 NTMS quadrangles located in the states of Minnesota and Wisconsin and seven (7) 2 0 x 1 0 NTMS quadrangles in North and South Dakota. The quadrangles located within the North and South Dakota survey area include Devil's Lake, New Rockford, Jamestown, Aberdeen, Huron, Mitchell, and Sioux Falls. This report discusses the results obtained over the Mitchell map area. The purpose of this program is to acquire and compile geologic and other information with which to assess the magnitude and distribution of uranium resources and to determine areas favorable for the occurrence of uranium in the United States. Traverse lines were flown in an east-west direction at a line spacing of six (6) miles. Tie lines were flown north-south approximately twenty-four (24) miles apart. A total of 21,481 line miles of geophysical data were acquired, compiled, and interpreted during the survey, of which 1479 line miles are in this quadrangle

  15. Airborne gamma-ray spectrometer and magnetometer survey: Huron quadrangle, South Dakota. Final report

    International Nuclear Information System (INIS)

    1981-04-01

    An airborne high sensitivity gamma-ray spectrometer and magnetometer survey was conducted over eleven (11) 2 0 x 1 0 NTMS quadrangles located in the states of Minnesota and Wisconsin and seven (7) 2 0 x 1 0 NTMS quadrangles in North and South Dakota. The quadrangles located within the North and South Dakota survey area include Devil's Lake, New Rockford, Jamestown, Aberdeen, Huron, Mitchell, and Sioux Falls. This report discusses the results obtained over the Huron map area. Traverse lines were flown in an east-west direction at a line spacing of six (6) miles. Tie lines were flown north-south approximately twenty-four (24) miles apart. A total of 21,481 line miles of geophysical data were acquired, compiled, and interpreted during the survey, of which 1459 line miles are in this quadrangle. The purpose of this study is to acquire and compile geologic and other information with which to assess the magnitude and distribution of uranium resources and to determine areas favorable for the occurrence of uranium in the United States

  16. Robust design of microlenses arrays employing dielectric resonators metasurfaces

    NARCIS (Netherlands)

    Silvestri, F.; Gerini, G.; Bäumer, S.M.B.

    2017-01-01

    In the last years, much interest has grown around the concept of optical surfaces employing high contrast dielectric resonators. However, a systematic approach for the design of this optical surfaces under particular requirements has never been proposed. In this contribution, we describe this

  17. Development of Search-Coil Magnetometer for Ultra Low Frequency (ULF) Wave Observations at Jang Bogo Station in Antarctica

    Science.gov (United States)

    Lee, J. K.; Shin, J.; Kim, K. H.; Jin, H.; Kim, H.; Kwon, J.; Lee, S.; Jee, G.; Lessard, M.

    2016-12-01

    A ground-based bi-axial search-coil magnetometer (SCM) has been devloped for observation of time-varying magnetic fields (dB/dt) in the Ultra Low Frequency (ULF) range (a few mHz up to 5 Hz) to understand magnetosphere-ionosphere coupling processes. The SCM consists of magnetic sensors, analog electronics, cables and data acquisition system (DAQ). The bi-axial magnetic sensor has coils of wire wound around a mu-metal cores, each of which measures magnetic field pulsations in the horizontal components, geomagnetic north-south and east-west, respectively. The analog electronics is designed to control the cut-off frequency of the instrument and to amplify detected signals. The DAQ has a 16 bit analog to digital converter (ADC) at the user defined rate of 10 Hz. It is also equipped with the Global Positioning System (GPS) and Network Time Protocol (NTP) for time synchronization and accuracy. We have carried out in-lab performance tests (e.g., frequency response, noise level, etc) using a magnetically shielded case and a field-test in a magnetically quiet location in South Korea. During the field test, a ULF Pi 2 event has been observed clearly. We also confirmed that it was a substorm activity from a fluxgate magnetometer data at Mineyama (35°57.3'N, 135°05'E, geographic). The SCM will be installed and operated at Jang Bogo Antarctic Research Station (74°37.4'S, 164°13.7'E, geographic) on Dec. 2016. The geomagnetic latitude of the station is similar to that of the US McMurdo station (77°51'S, 166°40'E, geographic), both of which are typically near the cusp region. Thus, we expect that the SCM can provide useful information to understand ULF wave propagation characteristics.

  18. Triaxial digital fluxgate magnetometer for NASA applications explorer mission: Results of tests of critical elements

    Science.gov (United States)

    Mcleod, M. G.; Means, J. D.

    1977-01-01

    Tests performed to prove the critical elements of the triaxial digital fluxgate magnetometer design were described. A method for improving the linearity of the analog to digital converter portion of the instrument was studied in detail. A sawtooth waveform was added to the signal being measured before the A/D conversion, and averaging the digital readings over one cycle of the sawtooth. It was intended to reduce bit error nonlinearities present in the A/D converter which could be expected to be as much as 16 gamma if not reduced. No such nonlinearities were detected in the output of the instrument which included the feature designed to reduce these nonlinearities. However, a small scale nonlinearity of plus or minus 2 gamma with a 64 gamma repetition rate was observed in the unit tested. A design improvement intended to eliminate this small scale nonlinearity was examined.

  19. Measurements on very small single crystals of NdFeB using a vibrating reed magnetometer

    International Nuclear Information System (INIS)

    Richter, H.J.; Hempel, K.A.; Verhoef, R.

    1988-01-01

    Nd 2 Fe 14 B single crystals with magnetic moments ranging from 1.6 x 10 -8 Acm 2 to 9.5 x 10 -7 Acm 2 are measured using the ultra high sensitivity vibrating reed magnetometer. The hysteresis loops are compared to those of BaFe 12 O 19 single crystals. It turns out that the magnetization reversal of the Nd 2 Fe 14 B samples is similar to that of BaFe 12 O 19 single crystals if the ferrite samples are considerably bigger in size. This does not hold for bigger Nd 2 Fe 14 B particles where stronger domain wall pinning is observed. For very small grains of Nd 2 Fe 14 B there is still evidence of domain wall processes while for BaFe 12 O 19 grains of the same size true single domain behaviour can be observed

  20. Optimizing the sensing performance of a single-rod fluxgate magnetometer using thin magnetic wires

    International Nuclear Information System (INIS)

    Can, Hava; Tanrıseven, Sercan; Birlikseven, Cengiz; Sözeri, Hüseyin; Topal, Uğur; Svec, Peter Jr; Svec, Peter Sr; Bydzovsky, Jan

    2015-01-01

    This paper presents the optimal conditions for the design of a single-rod fluxgate magnetometer using Co-based amorphous magnetic wires with reduced geometrical dimensions of 100 μm in diameter. In order to enhance the performance of the current sensor (i.e. the noise level, the sensitivity, the dynamical range, the scaling factor, etc), the core materials were subjected to annealing at different annealing temperatures in a longitudinal magnetic field ranging from 0 to 0.5 T. The B–H measurements have shown that the heat treatments significantly change the magnetic parameters of the cores (the saturation field, the initial and apparent permeabilities). For instance, the initial permeability μ i attains values of between 3500 and 4700 depending on the treatment conditions. These magnetic parameters were subsequently correlated with the sensor performance by using the principles of the fluxgate physics. Consequently, the enhanced fluxgate effect with improved sensing characteristics has been obtained by annealing the wire core at 250 °C (B  =  0 T). It is shown that this magnetic wire with a sensing area of 0.00785 mm 2 is suitable as a sensor core for the nondestructive testing of metallic objects and the surfaces of magnetic cards. The sensor signal shows perfect linear dependence to dc or low frequency fields up to ∼1 Oe. The fitting parameters R 2 of 0.9998 could be achieved in a dc field interval of  −1.0 Oe and 1.0 Oe (when R 2   =1.0, all points lie exactly on the curve with no scatter). Such linearity has not been seen in such a large dynamical range until now in the rod-type single-core fluxgates. It is also shown that there is no hysteresis on the V 2f –H dc graphs (the V 2f is the sensor signal) even after applying fields as high as 100 Oe. Besides, the cross-field effect is almost zero due to the geometry of the long-thin wire. (paper)

  1. Optimizing the sensing performance of a single-rod fluxgate magnetometer using thin magnetic wires

    Science.gov (United States)

    Can, Hava; Svec, Peter, Jr.; Tanrıseven, Sercan; Bydzovsky, Jan; Birlikseven, Cengiz; Sözeri, Hüseyin; Svec, Peter, Sr.; Topal, Uğur

    2015-11-01

    This paper presents the optimal conditions for the design of a single-rod fluxgate magnetometer using Co-based amorphous magnetic wires with reduced geometrical dimensions of 100 μm in diameter. In order to enhance the performance of the current sensor (i.e. the noise level, the sensitivity, the dynamical range, the scaling factor, etc), the core materials were subjected to annealing at different annealing temperatures in a longitudinal magnetic field ranging from 0 to 0.5 T. The B-H measurements have shown that the heat treatments significantly change the magnetic parameters of the cores (the saturation field, the initial and apparent permeabilities). For instance, the initial permeability μ i attains values of between 3500 and 4700 depending on the treatment conditions. These magnetic parameters were subsequently correlated with the sensor performance by using the principles of the fluxgate physics. Consequently, the enhanced fluxgate effect with improved sensing characteristics has been obtained by annealing the wire core at 250 °C (B  =  0 T). It is shown that this magnetic wire with a sensing area of 0.00785 mm2 is suitable as a sensor core for the nondestructive testing of metallic objects and the surfaces of magnetic cards. The sensor signal shows perfect linear dependence to dc or low frequency fields up to ~1 Oe. The fitting parameters R 2 of 0.9998 could be achieved in a dc field interval of  -1.0 Oe and 1.0 Oe (when R 2  =1.0, all points lie exactly on the curve with no scatter). Such linearity has not been seen in such a large dynamical range until now in the rod-type single-core fluxgates. It is also shown that there is no hysteresis on the V 2f -H dc graphs (the V 2f is the sensor signal) even after applying fields as high as 100 Oe. Besides, the cross-field effect is almost zero due to the geometry of the long-thin wire.

  2. Airborne gamma-ray spectrometer and magnetometer survey. Volume I. Final report

    International Nuclear Information System (INIS)

    An airborne combined radiometric and magnetic survey was performed for the Department of Energy (DOE) over the area covered by the Mariposa, California and Nevada; Fresno, California; and Bakersfield, Caifornia 1:250,000 National Topographic Map Series (NTMS) 1 0 x 2 0 quadrangle maps. The survey was a part of DOE's National Aerial Radiometric Reconnaissance (ARR) program, which in turn is a part of the National Uranium Resource Evaluation (NURE) program. Data were collected by a helicopter equipped with a gamma-ray spectrometer having a large crystal volume, and a high sensitivity proton precession magnetometer. The radiometric system was calibrated at the Walker Field Calibration pads and the Lake Mead Dynamic Test range. Data quality was ensured throughout the survey by daily test flights and equipment checks. Radiometric data were corrected for live time, aircraft and equipment background, cosmic background, atmospheric radon, Compton scatter, and altitude dependence. The corrected data were statistically evaluated, plotted, and contoured to produce anomaly maps based on the radiometric response of individual geological units. These maps were interpreted and an anomaly interpretation map produced. Volume I contains a description of the systems used in the survey, a discussion of the calibration of the systems, the data processing procedures, the data display format, the interpretation rationale, and the interpretation methodology. A separate Volume II for each quadrangle contains the data displays and the interpretation results

  3. Liquid extraction surface analysis (LESA) of food surfaces employing chip-based nano-electrospray mass spectrometry.

    Science.gov (United States)

    Eikel, Daniel; Henion, Jack

    2011-08-30

    An automated surface-sampling technique called liquid extraction surface analysis (LESA), coupled with infusion nano-electrospray high-resolution mass spectrometry and tandem mass spectrometry (MS/MS), is described and applied to the qualitative determination of surface chemical residues resulting from the artificial spraying of selected fresh fruits and vegetables with representative pesticides. Each of the targeted pesticides was readily detected with both high-resolution and full-scan collision-induced dissociation (CID) mass spectra. In the case of simazine and sevin, a mass resolution of 100,000 was insufficient to distinguish the isobaric protonated molecules for these compounds. When the surface of a spinach leaf was analyzed by LESA, trace levels of diazinon were readily detected on the spinach purchased directly from a supermarket before they were sprayed with the five-pesticide mixture. A 30 s rinse under hot running tap water appeared to quantitatively remove all remaining residues of this pesticide. Diazinon was readily detected by LESA analysis on the skin of the artificially sprayed spinach. Finally, incurred pyrimethanil at a level of 169 ppb in a batch slurry of homogenized apples was analyzed by LESA and this pesticide was readily detected by both high-resolution mass spectrometry and full-scan CID mass spectrometry, thus showing that pesticides may also be detected in whole fruit homogenized samples. This report shows that representative pesticides on fruit and vegetable surfaces present at levels 20-fold below generally allowed EPA tolerance levels are readily detected and confirmed by the title technologies making LESA-MS as interesting screening method for food safety purposes. Copyright © 2011 John Wiley & Sons, Ltd.

  4. Swarm Deployable Boom Assembly (DBA) Development of a Deployable Magnetometer Boom for the Swarm Spacecraft

    Science.gov (United States)

    McMahon, Paul; Jung, Hans-Juergen; Edwards, Jeff

    2013-09-01

    The Swarm programme consists of 3 magnetically clean satellites flying in close formation designed to measure the Earth's magnetic field using 2 Magnetometers mounted on a 4.3m long deployable boom.Deployment is initiated by releasing 3 HDRMs, once released the boom oscillates back and forth on a pair of pivots, similar to a restaurant kitchen door hinge, for around 120 seconds before coming to rest on 3 kinematic mounts which are used to provide an accurate reference location in the deployed position. Motion of the boom is damped through a combination of friction, spring hysteresis and flexing of the 120+ cables crossing the hinge. Considerable development work and accurate numerical modelling of the hinge motion was required to predict performance across a wide temperature range and ensure that during the 1st overshoot the boom did not damage itself, the harness or the spacecraft.Due to the magnetic cleanliness requirements of the spacecraft no magnetic materials could be used in the design of the hardware.

  5. Anisotropic effects in a powder oriented YBCO sample using a three axes magnetometer

    Energy Technology Data Exchange (ETDEWEB)

    Boudissa, M. [Universite Ferhat Abbas, Faculte des Sciences de l' Ingenieur, Setif (Algeria); Halimi, R. [Universite Mentouri, Unite de Recherche de Physique des Materiaux, Constantine (Algeria); Senoussi, S. [Universite Paris-Sud, Laboratoire de Physique des Solides, Orsay (France)

    2006-09-15

    To measure the components of the magnetization vector along the XYZ directions of a reference frame, in the superconducting materials, we have conceived a three axes magnetometer, with a detection system equipped with three series of pick-up coils with axes parallel to the three directions X,Y, and Z. We describe in this paper the details of the design and the method of measurement, with some results obtained by magnetic measurements on samples of oriented YBCO powder, with size of the grains between 20 {mu}m and 40 {mu}m, for values of the angle {theta} between the magnetic field H and the c-axis, between 0 and 90 and for values of fields up to 12 T. The direct measurement of the Z and the XY components of the irreversible magnetization vector, M{sub irr}, allowed us to observe the twin effect (channeling) on the vortex pinning observed by many authors, the evolution of the magnetization vector and to measure with a high accuracy the anisotropy factor of our samples. (copyright 2006 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  6. Anisotropic effects in a powder oriented YBCO sample using a three axes magnetometer

    International Nuclear Information System (INIS)

    Boudissa, M.; Halimi, R.; Senoussi, S.

    2006-01-01

    To measure the components of the magnetization vector along the XYZ directions of a reference frame, in the superconducting materials, we have conceived a three axes magnetometer, with a detection system equipped with three series of pick-up coils with axes parallel to the three directions X,Y, and Z. We describe in this paper the details of the design and the method of measurement, with some results obtained by magnetic measurements on samples of oriented YBCO powder, with size of the grains between 20 μm and 40 μm, for values of the angle θ between the magnetic field H and the c-axis, between 0 and 90 and for values of fields up to 12 T. The direct measurement of the Z and the XY components of the irreversible magnetization vector, M irr , allowed us to observe the twin effect (channeling) on the vortex pinning observed by many authors, the evolution of the magnetization vector and to measure with a high accuracy the anisotropy factor of our samples. (copyright 2006 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  7. Airborne gamma-ray spectrometer and magnetometer survey: Barrow Quadrangle, Alaska. Final report. Volume I

    International Nuclear Information System (INIS)

    1981-03-01

    During the months of July-August 1980, Aero Service Division Western Geophysical Company of America conducted an airborne high sensitivity gamma-ray spectrometer and magnetometer survey over eleven (11) 3 0 x 1 0 and one (1) 4 0 x 1 0 NTMS quadrangles of the Alaskan North Slope. This report discusses the results obtained over the Barrow map area. The final data are presented in four different forms: on magnetic tape; on microfiche; in graphic form as profiles and histograms; and in map form as anomaly maps, flight path maps, and computer printer maps. The histograms and the multiparameter profiles are presented with the anomaly maps and flight path map in a separate bound volume. Complete data listings of both the reduced single record and the reduced averaged record data are found in the back of this report. The format of the printout of the microfiches and the format of the data files delivered on magnetic tape are in accordance with the specifications of the BFEC 1200-C and are described in appendices F through L of this report

  8. Airborne gamma-ray spectrometer and magnetometer survey, New Rockford Quadrangle, North Dakota. Final report

    International Nuclear Information System (INIS)

    1981-04-01

    An airborne high sensitivity gamma-ray spectrometer and magnetometer survey was conducted over eleven (11) 2 0 x 1 0 NTMS quadrangles located in the states of Minnesota and Wisconsin and seven (7) 2 0 x 1 0 NTMS quadrangles in North and South Dakota. The quadrangles located within the North and South Dakota survey area include Devil's Lake, New Rockford, Jamestown, Aberdeen, Huron, Mitchell, and Sioux Falls. This report discusses the results obtained over the New Rockford map area. Traverse lines were flown in an east-west direction at a line spacing of six (6) miles. Tie lines were flown north-south approximately twenty-four (24) miles apart. A total of 21,481 line miles of geophysical data were acquired, compiled, and interpreted during the survey, of which 1397 line miles are in this quadrangle. The purpose of this study is to acquire and compile geologic and other information with which to assess the magnitude and distribution of uranium resources and to determine areas favorable for the occurrence of uranium in the United States

  9. The Pulse Azimuth effect as seen in induction coil magnetometers located in California and Peru 2007–2010, and its possible association with earthquakes

    Directory of Open Access Journals (Sweden)

    J. C. Dunson

    2011-07-01

    Full Text Available The QuakeFinder network of magnetometers has recorded geomagnetic field activity in California since 2000. Established as an effort to follow up observations of ULF activity reported from before and after the M = 7.1 Loma Prieta earthquake in 1989 by Stanford University, the QuakeFinder network has over 50 sites, fifteen of which are high-resolution QF1005 and QF1007 systems. Pairs of high-resolution sites have also been installed in Peru and Taiwan.

    Increases in pulse activity preceding nearby seismic events are followed by decreases in activity afterwards in the three cases that are discussed here. In addition, longer term data is shown, revealing a rich signal structure not previously known in QuakeFinder data, or by many other authors who have reported on pre-seismic ULF phenomena. These pulses occur as separate ensembles, with demonstrable repeatability and uniqueness across a number of properties such as waveform, angle of arrival, amplitude, and duration. Yet they appear to arrive with exponentially distributed inter-arrival times, which indicates a Poisson process rather than a periodic, i.e., stationary process.

    These pulses were observed using three-axis induction coil magnetometers that are buried 1–2 m under the surface of the Earth. Our sites use a Nyquist frequency of 16 Hertz (25 Hertz for the new QF1007 units, and they record these pulses at amplitudes from 0.1 to 20 nano-Tesla with durations of 0.1 to 12 s. They are predominantly unipolar pulses, which may imply charge migration, and they are stronger in the two horizontal (north-south and east-west channels than they are in the vertical channels. Pulses have been seen to occur in bursts lasting many hours. The pulses have large amplitudes and study of the three-axis data shows that the amplitude ratios of the pulses taken from pairs of orthogonal coils is stable across the bursts, suggesting a similar source.

    This paper presents three

  10. Employment status, employment functioning, and barriers to employment among VA primary care patients.

    Science.gov (United States)

    Zivin, Kara; Yosef, Matheos; Levine, Debra S; Abraham, Kristen M; Miller, Erin M; Henry, Jennifer; Nelson, C Beau; Pfeiffer, Paul N; Sripada, Rebecca K; Harrod, Molly; Valenstein, Marcia

    2016-03-15

    Prior research found lower employment rates among working-aged patients who use the VA than among non-Veterans or Veterans who do not use the VA, with the lowest reported employment rates among VA patients with mental disorders. This study assessed employment status, employment functioning, and barriers to employment among VA patients treated in primary care settings, and examined how depression and anxiety were associated with these outcomes. The sample included 287 VA patients treated in primary care in a large Midwestern VA Medical Center. Bivariate and multivariable analyses were conducted examining associations between socio-demographic and clinical predictors of six employment domains, including: employment status, job search self-efficacy, work performance, concerns about job loss among employed Veterans, and employment barriers and likelihood of job seeking among not employed Veterans. 54% of respondents were employed, 36% were not employed, and 10% were economically inactive. In adjusted analyses, participants with depression or anxiety (43%) were less likely to be employed, had lower job search self-efficacy, had lower levels of work performance, and reported more employment barriers. Depression and anxiety were not associated with perceived likelihood of job loss among employed or likelihood of job seeking among not employed. Single VA primary care clinic; cross-sectional study. Employment rates are low among working-aged VA primary care patients, particularly those with mental health conditions. Offering primary care interventions to patients that address mental health issues, job search self-efficacy, and work performance may be important in improving health, work, and economic outcomes. Published by Elsevier B.V.

  11. Magnetic field fluctuations measurement onboard ESA/JUICE mission by search-coil magnetometer: SCM instrument as a part of RPWI consortium

    Science.gov (United States)

    Retinò, A.; Chust, T.; Mansour, M.; Canu, P.; Sahraoui, F.; Le Contel, O.; Alison, D.; Sou, G.; Varizat, L.; Techer, J.-D.; Jeandet, A.; Geyskens, N.; Chariet, M.; Cecconi, B.; Bergman, J.; Wahlund, J.-E.; Santolik, O.; Soucek, J.; Dougherty, M.

    2017-09-01

    The JUpiter ICy moons Explorer (JUICE) mission is planned for launch in 2022 with arrival at Jupiter in 2029 and will spend at least three years making detailed observations of Jupiter's system. The Radio and Plasma Wave Investigation (RPWI) consortium will carry the most advanced set of electric and magnetic fields sensors ever flown therein, which will allow to characterize the plasma wave environment and the radio emission of Jupiter and its icy moons in great detail. The Search Coil Magnetometer (SCM) will provide high-quality measurements of the magnetic field fluctuations' vector for RPWI. Here we present the technical features of the SCM instrument and we discuss its scientific objectives.

  12. Soldiers’ employment attitude and employability: An exploratory study

    Directory of Open Access Journals (Sweden)

    Peng Gao

    2015-04-01

    Full Text Available Purpose: Nowadays it is very difficult for Chinese retired soldiers to find proper jobs, and the primary reason is the significant gap between job requirements and soldiers owned job skills. Therefore, it is very important to improve the soldiers’ job skills and enhance their understanding of employment.Design/methodology/approach: This paper expands the study scope from the soldiers’ job skills to the employability, initiatively introduces the employment attitude which has obvious impact on the employment of soldiers, and analyses the influence that employment attitude can play on employability. At last, this paper develops statistical method to find the relationship between soldiers’ employment attitude and employability.Findings: The empirical analysis shows that soldiers’ employment attitude has the positive linkage with employability, which makes the employment attitude a measurable variable for the employability rather than an absolute standard.Research limitations/implications: According to the research purpose, more variables should be considered in the model, consequently, there are only three indicators to describe solders’ employment attitude and four indicators to describe solders’ employability.Originality/value: This paper takes research on soldiers’ employability in a new perspective. The soldiers’ employment attitude is served as the entry point, showing the influence that soldiers’ employment attitude has on employability.

  13. Diamond Synthesis Employing Nanoparticle Seeds

    Science.gov (United States)

    Uppireddi, Kishore (Inventor); Morell, Gerardo (Inventor); Weiner, Brad R. (Inventor)

    2014-01-01

    Iron nanoparticles were employed to induce the synthesis of diamond on molybdenum, silicon, and quartz substrates. Diamond films were grown using conventional conditions for diamond synthesis by hot filament chemical vapor deposition, except that dispersed iron oxide nanoparticles replaced the seeding. This approach to diamond induction can be combined with dip pen nanolithography for the selective deposition of diamond and diamond patterning while avoiding surface damage associated to diamond-seeding methods.

  14. Internal Physical Features of a Land Surface Model Employing a Tangent Linear Model

    Science.gov (United States)

    Yang, Runhua; Cohn, Stephen E.; daSilva, Arlindo; Joiner, Joanna; Houser, Paul R.

    1997-01-01

    The Earth's land surface, including its biomass, is an integral part of the Earth's weather and climate system. Land surface heterogeneity, such as the type and amount of vegetative covering., has a profound effect on local weather variability and therefore on regional variations of the global climate. Surface conditions affect local weather and climate through a number of mechanisms. First, they determine the re-distribution of the net radiative energy received at the surface, through the atmosphere, from the sun. A certain fraction of this energy increases the surface ground temperature, another warms the near-surface atmosphere, and the rest evaporates surface water, which in turn creates clouds and causes precipitation. Second, they determine how much rainfall and snowmelt can be stored in the soil and how much instead runs off into waterways. Finally, surface conditions influence the near-surface concentration and distribution of greenhouse gases such as carbon dioxide. The processes through which these mechanisms interact with the atmosphere can be modeled mathematically, to within some degree of uncertainty, on the basis of underlying physical principles. Such a land surface model provides predictive capability for surface variables including ground temperature, surface humidity, and soil moisture and temperature. This information is important for agriculture and industry, as well as for addressing fundamental scientific questions concerning global and local climate change. In this study we apply a methodology known as tangent linear modeling to help us understand more deeply, the behavior of the Mosaic land surface model, a model that has been developed over the past several years at NASA/GSFC. This methodology allows us to examine, directly and quantitatively, the dependence of prediction errors in land surface variables upon different vegetation conditions. The work also highlights the importance of accurate soil moisture information. Although surface

  15. Investigation of synthetic aperture methods in ultrasound surface imaging using elementary surface types.

    Science.gov (United States)

    Kerr, W; Pierce, S G; Rowe, P

    2016-12-01

    Synthetic aperture imaging methods have been employed widely in recent research in non-destructive testing (NDT), but uptake has been more limited in medical ultrasound imaging. Typically offering superior focussing power over more traditional phased array methods, these techniques have been employed in NDT applications to locate and characterise small defects within large samples, but have rarely been used to image surfaces. A desire to ultimately employ ultrasonic surface imaging for bone surface geometry measurement prior to surgical intervention motivates this research, and results are presented for initial laboratory trials of a surface reconstruction technique based on global thresholding of ultrasonic 3D point cloud data. In this study, representative geometry artefacts were imaged in the laboratory using two synthetic aperture techniques; the Total Focusing Method (TFM) and the Synthetic Aperture Focusing Technique (SAFT) employing full and narrow synthetic apertures, respectively. Three high precision metallic samples of known geometries (cuboid, sphere and cylinder) which featured a range of elementary surface primitives were imaged using a 5MHz, 128 element 1D phased array employing both SAFT and TFM approaches. The array was manipulated around the samples using a precision robotic positioning system, allowing for repeatable ultrasound derived 3D surface point clouds to be created. A global thresholding technique was then developed that allowed the extraction of the surface profiles, and these were compared with the known geometry samples to provide a quantitative measure of error of 3D surface reconstruction. The mean errors achieved with optimised SAFT imaging for the cuboidal, spherical and cylindrical samples were 1.3mm, 2.9mm and 2.0mm respectively, while those for TFM imaging were 3.7mm, 3.0mm and 3.1mm, respectively. These results were contrary to expectations given the higher information content associated with the TFM images. However, it was

  16. Signal Conditioning for the Kalman Filter: Application to Satellite Attitude Estimation with Magnetometer and Sun Sensors.

    Science.gov (United States)

    Esteban, Segundo; Girón-Sierra, Jose M; Polo, Óscar R; Angulo, Manuel

    2016-10-31

    Most satellites use an on-board attitude estimation system, based on available sensors. In the case of low-cost satellites, which are of increasing interest, it is usual to use magnetometers and Sun sensors. A Kalman filter is commonly recommended for the estimation, to simultaneously exploit the information from sensors and from a mathematical model of the satellite motion. It would be also convenient to adhere to a quaternion representation. This article focuses on some problems linked to this context. The state of the system should be represented in observable form. Singularities due to alignment of measured vectors cause estimation problems. Accommodation of the Kalman filter originates convergence difficulties. The article includes a new proposal that solves these problems, not needing changes in the Kalman filter algorithm. In addition, the article includes assessment of different errors, initialization values for the Kalman filter; and considers the influence of the magnetic dipole moment perturbation, showing how to handle it as part of the Kalman filter framework.

  17. Signal Conditioning for the Kalman Filter: Application to Satellite Attitude Estimation with Magnetometer and Sun Sensors

    Directory of Open Access Journals (Sweden)

    Segundo Esteban

    2016-10-01

    Full Text Available Most satellites use an on-board attitude estimation system, based on available sensors. In the case of low-cost satellites, which are of increasing interest, it is usual to use magnetometers and Sun sensors. A Kalman filter is commonly recommended for the estimation, to simultaneously exploit the information from sensors and from a mathematical model of the satellite motion. It would be also convenient to adhere to a quaternion representation. This article focuses on some problems linked to this context. The state of the system should be represented in observable form. Singularities due to alignment of measured vectors cause estimation problems. Accommodation of the Kalman filter originates convergence difficulties. The article includes a new proposal that solves these problems, not needing changes in the Kalman filter algorithm. In addition, the article includes assessment of different errors, initialization values for the Kalman filter; and considers the influence of the magnetic dipole moment perturbation, showing how to handle it as part of the Kalman filter framework.

  18. Development of an extraction type magnetometer under high pressure and high magnetic fields over 200 kOe in the hybrid magnet

    International Nuclear Information System (INIS)

    Koyama, K; Miura, S; Okada, H; Watanabe, K

    2006-01-01

    An extraction-type magnetometer has been developed, which is performed under pressures up to 12 kbar using a miniature high-pressure clamp-cell, in magnetic fields up to 270 kOe using our hybrid magnet and at the temperature range from 1.5 to 300 K. Magnetization curves can be measured for absolute value over 0.04 emu. We confirmed that resolution is about ±0.01 emu under high pressures and high magnetic fields if a sample has the magnetic moment of about 3 emu. For demonstrating the ability of the instrument, high field magnetization curves for SmMn 2 Ge 2 under high pressures are presented

  19. Evaluating Employability Skills: Employer and Student Perceptions

    Science.gov (United States)

    Saunders, Venetia; Zuzel, Katherine

    2010-01-01

    Graduate employability is a key issue for Higher Education. In this two-part study student employability skills have been evaluated from the perspective of sandwich students and graduates in biomolecular science, and their employers. A strong correlation was found between employer and sandwich student/graduate perceptions of the relative…

  20. Vector magnetometer based on synchronous manipulation of nitrogen-vacancy centers in all crystal directions

    Science.gov (United States)

    Zhang, Chen; Yuan, Heng; Zhang, Ning; Xu, Lixia; Zhang, Jixing; Li, Bo; Fang, Jiancheng

    2018-04-01

    Negatively charged nitrogen vacancy (NV‑) centers in diamond have been extensively studied as high-sensitivity magnetometers, showcasing a wide range of applications. This study experimentally demonstrates a vector magnetometry scheme based on synchronous manipulation of NV‑ center ensembles in all crystal directions using double frequency microwaves (MWs) and multi-coupled-strip-lines (mCSL) waveguide. The application of the mCSL waveguide ensures a high degree of synchrony (99%) for manipulating NV‑ centers in multiple orientations in a large volume. Manipulation with double frequency MWs makes NV‑ centers of all four crystal directions involved, and additionally leads to an enhancement of the manipulation field. In this work, by monitoring the changes in the slope of the resonance line consisting of multi-axes NV‑ centers, measurement of the direction of the external field vector was demonstrated with a sensitivity of {{10}\\prime}/\\sqrt{Hz} . Based on the scheme, the fluorescence signal contrast was improved by four times higher and the sensitivity to the magnetic field strength was improved by two times. The method provides a more practical way of achieving vector sensors based on NV‑ center ensembles in diamond.

  1. Activation of room temperature ferromagnetism in ZnO films by surface functionalization with thiol and amine

    International Nuclear Information System (INIS)

    Jayalakshmi, G.; Gopalakrishnan, N.; Balasubramanian, T.

    2013-01-01

    Highlights: ► Room temperature ferromagnetism (RTFM) is observed in surface functionalized ZnO films. ► Surface functionalization is a new approach to make ZnO as ferromagnetic. ► The RTFM is attributed to the interaction between the adsorbates and the surface of ZnO. ► The oxygen vacancies are passivated upon surface functionalization. - Abstract: In this paper, we report the activation of room temperature ferromagnetism in ZnO films by surface functionalization with thiol and amine. The pure and surface functionalized ZnO films have been examined by X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), photoluminescence (PL) and vibrating sample magnetometer (VSM) measurements. XRD measurements show that all the films have single phase and (0 0 2) preferred orientation. The chemical bonding of ZnO with thiol and amine molecules has been confirmed by XPS measurements. The quenching of visible emission in PL spectra indicates that the surface defects are passivated by functionalization with thiol and amine. Surface functionalization of ZnO films with thiol and amine induces robust room temperature ferromagnetism in ZnO films as evidenced from VSM measurements. It is concluded that the observed ferromagnetic behavior in functionalized ZnO films is attributed to the different electronegativity of the atom in the thiol (or amine) and the surface of ZnO.

  2. Detecting molecules and cells labeled with magnetic particles using an atomic magnetometer

    International Nuclear Information System (INIS)

    Yu Dindi; Ruangchaithaweesuk, Songtham; Yao Li; Xu Shoujun

    2012-01-01

    The detection of magnetically labeled molecules and cells involves three essential parameters: sensitivity, spatial resolution, and molecular specificity. We report on the use of atomic magnetometry and its derivative techniques to achieve high performance in terms of all these parameters. With a sensitivity of 80 fT/√Hz for dc magnetic fields, we show that 7,000 streptavidin-conjugated magnetic microparticles magnetized by a permanent magnet produce a magnetic field of 650 pT; this result predicts that a single such particle can be detected during one second of signal averaging. Spatial information is obtained using a scanning magnetic imaging scheme. The spatial resolution is 20 μm with a detection distance of more than 1 cm; this distance is much longer than that in previous reports. The molecular specificity is achieved using force-induced remnant magnetization spectroscopy, which currently uses an atomic magnetometer for detection. As an example, we perform measurement of magnetically labeled human CD4+ T cells, whose count in the blood is the diagnostic criterion for human immunodeficiency virus infection. Magnetic particles that are specifically bound to the cells are resolved from nonspecifically bound particles and quantitatively correlate with the number of cells. The magnetic particles have an overall size of 2.8 μm, with a magnetic core in nanometer regime. The combination of our techniques is predicted to be useful in molecular and cellular imaging.

  3. Detecting molecules and cells labeled with magnetic particles using an atomic magnetometer

    Energy Technology Data Exchange (ETDEWEB)

    Yu Dindi; Ruangchaithaweesuk, Songtham; Yao Li; Xu Shoujun, E-mail: sxu7@uh.edu [University of Houston, Department of Chemistry (United States)

    2012-09-15

    The detection of magnetically labeled molecules and cells involves three essential parameters: sensitivity, spatial resolution, and molecular specificity. We report on the use of atomic magnetometry and its derivative techniques to achieve high performance in terms of all these parameters. With a sensitivity of 80 fT/{radical}Hz for dc magnetic fields, we show that 7,000 streptavidin-conjugated magnetic microparticles magnetized by a permanent magnet produce a magnetic field of 650 pT; this result predicts that a single such particle can be detected during one second of signal averaging. Spatial information is obtained using a scanning magnetic imaging scheme. The spatial resolution is 20 {mu}m with a detection distance of more than 1 cm; this distance is much longer than that in previous reports. The molecular specificity is achieved using force-induced remnant magnetization spectroscopy, which currently uses an atomic magnetometer for detection. As an example, we perform measurement of magnetically labeled human CD4+ T cells, whose count in the blood is the diagnostic criterion for human immunodeficiency virus infection. Magnetic particles that are specifically bound to the cells are resolved from nonspecifically bound particles and quantitatively correlate with the number of cells. The magnetic particles have an overall size of 2.8 {mu}m, with a magnetic core in nanometer regime. The combination of our techniques is predicted to be useful in molecular and cellular imaging.

  4. Real-space imaging of non-collinear antiferromagnetic order with a single-spin magnetometer

    Science.gov (United States)

    Gross, I.; Akhtar, W.; Garcia, V.; Martínez, L. J.; Chouaieb, S.; Garcia, K.; Carrétéro, C.; Barthélémy, A.; Appel, P.; Maletinsky, P.; Kim, J.-V.; Chauleau, J. Y.; Jaouen, N.; Viret, M.; Bibes, M.; Fusil, S.; Jacques, V.

    2017-09-01

    Although ferromagnets have many applications, their large magnetization and the resulting energy cost for switching magnetic moments bring into question their suitability for reliable low-power spintronic devices. Non-collinear antiferromagnetic systems do not suffer from this problem, and often have extra functionalities: non-collinear spin order may break space-inversion symmetry and thus allow electric-field control of magnetism, or may produce emergent spin-orbit effects that enable efficient spin-charge interconversion. To harness these traits for next-generation spintronics, the nanoscale control and imaging capabilities that are now routine for ferromagnets must be developed for antiferromagnetic systems. Here, using a non-invasive, scanning single-spin magnetometer based on a nitrogen-vacancy defect in diamond, we demonstrate real-space visualization of non-collinear antiferromagnetic order in a magnetic thin film at room temperature. We image the spin cycloid of a multiferroic bismuth ferrite (BiFeO3) thin film and extract a period of about 70 nanometres, consistent with values determined by macroscopic diffraction. In addition, we take advantage of the magnetoelectric coupling present in BiFeO3 to manipulate the cycloid propagation direction by an electric field. Besides highlighting the potential of nitrogen-vacancy magnetometry for imaging complex antiferromagnetic orders at the nanoscale, these results demonstrate how BiFeO3 can be used in the design of reconfigurable nanoscale spin textures.

  5. In-Flight Calibration Methods for Temperature-Dependent Offsets in the MMS Fluxgate Magnetometers

    Science.gov (United States)

    Bromund, K. R.; Plaschke, F.; Strangeway, R. J.; Anderson, B. J.; Huang, B. G.; Magnes, W.; Fischer, D.; Nakamura, R.; Leinweber, H. K.; Russell, C. T.; hide

    2016-01-01

    During the first dayside season of the Magnetospheric Multiscale (MMS) mission, the in-flight calibration process for the Fluxgate magnetometers (FGM) implemented an algorithm that selected a constant offset (zero-level) for each sensor on each orbit. This method was generally able to reduce the amplitude of residual spin tone to less than 0.2 nT within the region of interest. However, there are times when the offsets do show significant short-term variations. These variations are most prominent in the nighttime season (phase 1X), when eclipses are accompanied by offset changes as large as 1 nT. Eclipses are followed by a recovery period as long as 12 hours where the offsets continue to change as temperatures stabilize. Understanding and compensating for these changes will become critical during Phase 2 of the mission in 2017, when the nightside will become the focus of MMS science. Although there is no direct correlation between offset and temperature, the offsets are seen for the period of any given week to be well-characterized as function of instrument temperature. Using this property, a new calibration method has been developed that has proven effective in compensating for temperature-dependent offsets during phase 1X of the MMS mission and also promises to further refine calibration quality during the dayside season.

  6. Analysis of digital fluxgate magnetometer and radon data of MPGO network in Kachchh

    International Nuclear Information System (INIS)

    Prasad, M.S.B.S.; Gupta, Arun; Pradhan, Rashmi; Rastogi, B.K.; Rawat, Gautam

    2010-01-01

    Institute of Seismological Research (ISR) has established a network of four Multi-parametric Geophysical Observatories (MPGO) at Bhachau, Vamka, Desalpar and Badargadh in Kachchh which fall in the aftershock zone of 2001 Bhuj earthquake (Mw 7.7) for earthquake prediction research. Two Magson digital fluxgate magnetometers (DFM) have been installed on February 07, 2009 to observe magnetic precursors, if any, at Desalpar and Vamka in Kachchh. The daily variations of geomagnetic horizontal and vertical components are being continuously observed at a sampling interval of 1 Hz. Variations of about 2-9 nT in vertical component have been observed during earthquakes of Mw = 4 occurring within a radius of 65 km from Vamka and 80 km from Desalpar. Conventional polarization analysis of DFM data is implemented to check lithospheric origin of electromagnetic signals. Geomagnetic transfer function is calculated to observe any subsurface conductivity variation beneath the measuring sites. Further a strong radon anomaly at Vamka and Chobari sites has been observed 7 days before Mw 4.1 earthquake of 12 April 2009 which is at a distance of 29 km W from Vamka and 23 Km SW from Chobari. DFM and Radon sensors were installed as a part of MPGO instruments and these data will be supplemented by several other parameters. Preliminary results will be presented and discussed in the meetings. (author)

  7. In-Flight Calibration Methods for Temperature-Dependendent Offsets in the MMS Fluxgate Magnetometers

    Science.gov (United States)

    Bromund, K. R.; Plaschke, F.; Strangeway, R. J.; Anderson, B. J.; Huang, B. G.; Magnes, W.; Fischer, D.; Nakamura, R.; Leinweber, H. K.; Russell, C. T.; Baumjohann, W.; Chutter, M.; Torbert, R. B.; Le, G.; Slavin, J. A.; Kepko, L.

    2016-12-01

    During the first dayside season of the Magnetospheric Multiscale (MMS) mission, the in-flight calibration process for the Fluxgate magnetometers (FGM) implemented an algorithm that selected a constant offset (zero-level) for each sensor on each orbit. This method was generally able to reduce the amplitude of residual spin tone to less than 0.2 nT within the region of interest. However, there are times when the offsets do show significant short-term variations. These variations are most prominent in the nighttime season (phase 1X), when eclipses are accompanied by offset changes as large as 1 nT. Eclipses are followed by a recovery period as long as 12 hours where the offsets continue to change as temperatures stabilize. Understanding and compensating for these changes will become critical during Phase 2 of the mission in 2017, when the nightside will become the focus of MMS science. Although there is no direct correlation between offset and temperature, the offsets are seen — for the period of any given week — to be well-characterized as function of instrument temperature. Using this property, a new calibration method has been developed that has proven effective in compensating for temperature-dependent offsets during phase 1X of the MMS mission and also promises to further refine calibration quality during the dayside season.

  8. Airborne gamma-ray spectrometer and magnetometer survey: Peoria, Decater, Belleville Quadrangles, (IL). Final report

    International Nuclear Information System (INIS)

    1981-01-01

    An airborne combined radiometric and magnetic survey was performed for the Department of Energy (DOE) over the area covered by the Peoria, Decatur, and Belleville, 1:250,000 National Topographic Map Series (NTMS), quadrangle maps. The survey was part of DOE's National Uranium Resource Evaluation (NURE) program. Data were collected by a helicopter equipped with a gamma-ray spectrometer with a large crystal volume, and with a high sensitivity proton procession magnetometer. The radiometric system was calibrated at the Walker Field Calibration pads and the Lake Mead Dynamic Test Range. Data quality was ensured during the survey by daily test flights and equipment checks. Radiometric data were corrected for live time, aircraft and equipment background, cosmic background, atmospheric radon, Compton scatter, and altitude dependence. The corrected data were statistically evaluated, plotted, and contoured to produce anomaly maps based on the radiometric response of individual geological units. The anomalies were interpreted and an interpretation map produced. Volume I contains a description of the systems used in the survey, a discussion of the calibration of the systems, the data collection procedures, the data processing procedures, the data presentation, the interpretation rationale, and the interpretation methodology. A separate Volume II for each quadrangle contains the data displays and the interpretation results

  9. Continued Development of Meandering Winding Magnetometer (MWM (Register Trademark)) Eddy Current Sensors for the Health Monitoring, Modeling and Damage Detection of Composite Overwrapped Pressure Vessels

    Science.gov (United States)

    Russell, Richard; Wincheski, Russell; Jablonski, David; Washabaugh, Andy; Sheiretov, Yanko; Martin, Christopher; Goldfine, Neil

    2011-01-01

    Composite Overwrapped Pressure Vessels (COPVs) are used in essentially all NASA spacecraft, launch. vehicles and payloads to contain high-pressure fluids for propulsion, life support systems and science experiments. Failure of any COPV either in flight or during ground processing would result in catastrophic damage to the spacecraft or payload, and could lead to loss of life. Therefore, NASA continues to investigate new methods to non-destructively inspect (NDE) COPVs for structural anomalies and to provide a means for in-situ structural health monitoring (SHM) during operational service. Partnering with JENTEK Sensors, engineers at NASA, Kennedy Space Center have successfully conducted a proof-of-concept study to develop Meandering Winding Magnetometer (MWM) eddy current sensors designed to make direct measurements of the stresses of the internal layers of a carbon fiber composite wrapped COPV. During this study three different MWM sensors were tested at three orientations to demonstrate the ability of the technology to measure stresses at various fiber orientations and depths. These results showed good correlation with actual surface strain gage measurements. MWM-Array technology for scanning COPVs can reliably be used to image and detect mechanical damage. To validate this conclusion, several COPVs were scanned to obtain a baseline, and then each COPV was impacted at varying energy levels and then rescanned. The baseline subtracted images were used to demonstrate damage detection. These scans were performed with two different MWM-Arrays. with different geometries for near-surface and deeper penetration imaging at multiple frequencies and in multiple orientations of the linear MWM drive. This presentation will include a review of micromechanical models that relate measured sensor responses to composite material constituent properties, validated by the proof of concept study, as the basis for SHM and NDE data analysis as well as potential improvements including

  10. Surface electric fields for North America during historical geomagnetic storms

    Science.gov (United States)

    Wei, Lisa H.; Homeier, Nichole; Gannon, Jennifer L.

    2013-01-01

    To better understand the impact of geomagnetic disturbances on the electric grid, we recreate surface electric fields from two historical geomagnetic storms—the 1989 “Quebec” storm and the 2003 “Halloween” storms. Using the Spherical Elementary Current Systems method, we interpolate sparsely distributed magnetometer data across North America. We find good agreement between the measured and interpolated data, with larger RMS deviations at higher latitudes corresponding to larger magnetic field variations. The interpolated magnetic field data are combined with surface impedances for 25 unique physiographic regions from the United States Geological Survey and literature to estimate the horizontal, orthogonal surface electric fields in 1 min time steps. The induced horizontal electric field strongly depends on the local surface impedance, resulting in surprisingly strong electric field amplitudes along the Atlantic and Gulf Coast. The relative peak electric field amplitude of each physiographic region, normalized to the value in the Interior Plains region, varies by a factor of 2 for different input magnetic field time series. The order of peak electric field amplitudes (largest to smallest), however, does not depend much on the input. These results suggest that regions at lower magnetic latitudes with high ground resistivities are also at risk from the effect of geomagnetically induced currents. The historical electric field time series are useful for estimating the flow of the induced currents through long transmission lines to study power flow and grid stability during geomagnetic disturbances.

  11. The Employer Perspective on Sustainable Employability in the Construction Industry

    NARCIS (Netherlands)

    Tonnon, Susanne C; van der Veen, Rozan; Westerman, Marjan J; Robroek, Suzan J W; van der Ploeg, Hidde P; Van Der Beek, Allard J.; Proper, Karin I.

    OBJECTIVE: To determine the measures employers in the construction industry take to promote sustainable employability, the barriers and facilitators that influence implementation and employer needs. METHODS: Questionnaire among 499 employers and interviews with 17 employers. RESULTS: Employers

  12. Influence of the dynamic Stark effect on long-term frequency stability of a self-oscillating magnetometer with laser-pumped alkali atoms

    Science.gov (United States)

    Baranov, A. A.; Ermak, S. V.; Kulachenkov, N. K.; Petrenko, M. V.; Sagitov, E. A.; Semenov, V. V.

    2017-11-01

    This paper presents the results of investigation Stark shift effect influence on the long-term stability of a dual scheme of quantum magnetometers. Such scheme allows suppressing Stark shift components when a certain pumping light polarization is applied. As a result, long-term stability of a quantum sensor increases. However, when low-frequency (LF) and microwave fields are attached to a single vapor cell a coherence circulation in hyperfine structure of alkali atoms takes place. Physical origin of this effect is associated with the so called “dressed” atom theory, when atom is “dressed” by LF field. It yields in multiphoton absorption and resonance frequency shift. First estimates for this shift based on density matrix evolution formalism are provided in the paper.

  13. U.S. Navy Employment Options for Unmanned Surface Vehicles (USVs)

    Science.gov (United States)

    2013-01-01

    the Navy had cleared in compliance with the Paris Peace Accords. The second condition under which minefield proofing is conducted is when there is...www.gdrs.com/about/profile/pdfs/UDTPacific2006_4A3_.pdf Bertram, Volker, “Unmanned Surface Vehicles: A Survey,” Brest , France: ENSIETA, 2008. As of

  14. First-Generation Jet Propulsion Laboratory "Hockey-Puck" Free-Flying Magnetometers for Distributed In-Situ Multiprobe Measurement of Current Density Filamentation in the Northern Auroral Zone: Enstrophy Mission

    Science.gov (United States)

    Javadi, H.; Blaes, B.; Boehm, M.; Boykins, K.; Gibbs, J.; Goodman, W.; Lieneweg, U.; Lux, J.; Lynch, K.; Narvaez, P.

    2000-01-01

    The sub-orbital rocket mission was a collaborative project between the University of New Hampshire, Cornell University, and the Jet Propulsion Laboratory (JPL) to study filamentation phenomena in the northern Auroral zone. The Enstrophy mission test flies the JPL Free-Flying Magnetometer (FFM) concept. The FFM technology development task has been funded by NASA develop miniaturized, low-power, integrated "sensorcrafts". JPL's role was to design, integrate, test, and deliver four FFMs for deployment from the sounding rocket, allowing a unique determination of curl-B. This provides a direct measurement of magnetic-field-aligned current density along the rocket trajectory. A miniaturized three-axis fluxgate magnetometer was integrated with a 4-channel 22-bit sigma-delta Analog to Digital Converter (ADC), four temperature sensors, digital control electronics, seven (Li-SOCl2) batteries, two (4 deg x 170 deg field of view) sun-sensors, a fan-shaped-beam laser diode beacon, a (16 MHz) stable Temperature Compensated Crystal Oscillator (TCXO) clock, Radio Frequency (RF) communication subsystem, and an antenna for approximately 15 minutes of operation where data was collected continuously and transmitted in three (3) bursts (approximately 26 seconds each) to ground station antennas at Poker Flat, Alaska. FFMs were stowed within two trays onboard the rocket during the rocket launch and were released simultaneously using the spinning action of the rocket at approximately 300 km altitude (approximately 100 sec. into the flight). FFMs were deployed with spin rate of approximately 17 Hz and approximately 3 m/sec linear velocity with respect to the rocket. For testing purposes while the rocket was in the launch pad and during flight prior to release of FFMs from the rocket, commands (such as "power on", "test", "flight", "power off', and clock "Reset" signal) were transmitted via a infrared Light Emitting Diode to an infrared detector in the FFM. Special attention was paid to low

  15. Is Self-Employment Really a Bad Experience? The Effects of Previous Self-Employment on Subsequent Wage-Employment Wages

    DEFF Research Database (Denmark)

    Kaiser, Ulrich; Malchow-Møller, Nikolaj

    2011-01-01

    of self-employment is associated with lower hourly wages compared to workers who were consecutively wage-employed. We also show, however, that this effect disappears—and even becomes positive in some settings—for formerly self-employed who find dependent employment in the same sector as their self......-employment sector. Hence, the on average negative effect of self-employment is rather caused by sector switching than by the self-employment experience per se. Moreover, formerly self-employed who either enjoyed a high income or hired at least one worker during their self-employment spell receive wages...... in subsequent dependent employment that are at least as high as for individuals who have been consecutively wage-employed....

  16. Graduate Employability: A Conceptual Framework for Understanding Employers' Perceptions

    Science.gov (United States)

    Cai, Yuzhuo

    2013-01-01

    This study provides a conceptual framework for understanding what employers think about the value of graduates with similar educational credentials in the workplace (their employability), using insights from the new institutionalism. In this framework, the development of employers' beliefs about graduates' employability is broken into a number of…

  17. Employing Discourse: Universities and Graduate "Employability"

    Science.gov (United States)

    Boden, Rebecca; Nedeva, Maria

    2010-01-01

    What constitutes graduate employability is discursively framed. In this paper we argue that whilst universities in the UK have long had an involvement in producing useful and productive citizens, the ongoing neoliberalisation of higher education has engendered a discursive shift in definitions of employability. Traditionally, universities regarded…

  18. Report on gravity measurements and replacement of an unmanned magnetometer in the Sor Rondane Mountains, Eastern Dronning Maud Land, 2013 (JARE-55

    Directory of Open Access Journals (Sweden)

    Yusuke Suganuma

    2014-11-01

    Full Text Available Gravity measurements, replacement of the unmanned magnetometer, and a reconnaissance flight to the Belgica Mountains were carried out in the Sor Rondane Mountains as a part of the 55 th Japanese Antarctic Research Expedition (JARE-55. The field party comprised two geodesists, one geomorphologists, and one magnetospheric scientist. The Belgian Antarctic Research Expedition (BELARE and International Polar Foundation (IPF supported this field expedition. Dronning Maud Land Air Network (DROMLAN provided airborne access from Cape Town, South Africa to the Sor Rondane Mountains via Novolazarevskaya Airbase. The survey areas of this field expedition are the central parts of the Sor Rondane Mountains and the Belgica Mountains. This report summarizes the field expedition in terms of operations, logistics, and weather observations.

  19. 75 FR 3168 - Vocational Rehabilitation and Employment Program-Self-Employment

    Science.gov (United States)

    2010-01-20

    ... Employment Program--Self-Employment AGENCY: Department of Veterans Affairs. ACTION: Final rule. SUMMARY: This document amends the vocational rehabilitation and employment regulations of the Department of Veterans Affairs (VA) concerning self-employment for individuals with qualifying disabilities. We are making...

  20. NV Diamond Micro-Magnetometer Baseline Studies

    Science.gov (United States)

    2009-08-12

    to define circular masks of diameters ranging from 100-250nm on the surface. An anisotropic etch was used to transfer the pattern into the crystal...between NV and nearby 13C. (b) Pulse sequence for transfer of electron spin coherence to nuclear spin and repetitive readout. (c) Cumulative Rabi

  1. Employment specialist competencies for supported employment programs

    NARCIS (Netherlands)

    Corbière, M.; Brouwers, E.P.M.; Lanctôt, N.; van Weeghel, J.

    2014-01-01

    Purpose Supported employment (SE) programs are evidence-based programs offered to people with severe mental illness to facilitate obtaining and keeping competitive work. However, significant variations in individuals’ vocational success may be partly explained by differences in their employment

  2. Development of Meandering Winding Magnetometer (MWM (Register Trademark)) Eddy Current Sensors for the Health Monitoring, Modeling and Damage Detection of High Temperature Composite Materials

    Science.gov (United States)

    Russell, Richard; Washabaugh, Andy; Sheiretov, Yanko; Martin, Christopher; Goldfine, Neil

    2011-01-01

    The increased use of high-temperature composite materials in modern and next generation aircraft and spacecraft have led to the need for improved nondestructive evaluation and health monitoring techniques. Such technologies are desirable to improve quality control, damage detection, stress evaluation and temperature measurement capabilities. Novel eddy current sensors and sensor arrays, such as Meandering Winding Magnetometers (MWMs) have provided alternate or complimentary techniques to ultrasound and thermography for both nondestructive evaluation (NDE) and structural health monitoring (SHM). This includes imaging of composite material quality, damage detection and .the monitoring of fiber temperatures and multidirectional stresses. Historically, implementation of MWM technology for the inspection of the Space Shuttle Orbiter Reinforced Carbon-Carbon Composite (RCC) leading edge panels was developed by JENTEK Sensors and was subsequently transitioned by NASA as an operational pre and post flight in-situ inspection at the Kennedy Space Center. A manual scanner, which conformed'automatically to the curvature of the RCC panels was developed and used as a secondary technique if a defect was found during an infrared thermography screening, During a recent proof of concept study on composite overwrapped pressure vessels (COPV's), three different MWM sensors were tested at three orientations to demonstrate the ability of the technology to measure stresses at various fiber orientations and depths. These results showed excellent correlation with actual surface strain gage measurements. Recent advancements of this technology have been made applying MWM sensor technology for scanning COPVs for mechanical damage. This presentation will outline the recent advance in the MWM.technology and the development of MWM techniques for NDE and SHM of carbon wraped composite overwrapped pressure vessels (COPVs) including the measurement of internal stresses via a surface mounted sensor

  3. Effect of low-frequency ambient magnetic fields on the control unit and RF head of a commercial SQUID magnetometer

    Science.gov (United States)

    Marcus, C. M.

    1984-01-01

    The control unit and RF head of the SHE model 330XRFSQUID system are shown to be sensitive to ambient ac magnetic fields below 1 HZ, which cause the appearance of false signals corresponding to a magnetometer signal of 0.000001 phi(0) per gauss of field applied. The control unit shows a sensitivity that is linear with frequency, suggesting that the signal is generated by Faraday induction. In contrast, the RF head response is independent of frequency and shows a strong second-harmonic coversion. This response may be due to the magnetic field sensitivity of the ferrite core inductor in the tuned amplifier of the RF head. These signals induced by ambient fields are a potential source of error in Stanford's Relativity Gyroscope experiment, which uses SQUID's on board a rolling satellite as part of the gyroscope readout system. The extent of the magnetic field sensitivity in these components necessitates the use of additional magnetic shielding aboard the satellite.

  4. Breastfeeding and employment: an assessment of employer attitudes.

    Science.gov (United States)

    Libbus, M Kay; Bullock, Linda F C

    2002-08-01

    Both research and anecdotal reports suggest that maternal employment is associated with failure to initiate breastfeeding and early breastfeeding attrition. The objective of this study was to describe the experience with and attitudes toward breastfeeding of a sample of employers in a small Midwestern city in the United States. Based on an analysis of 85 mail-out questionnaires, we found that less than half of the employers had personal experience with breastfeeding. A large percentage of the sample, however, indicated that they would be willing to facilitate women who wished to breastfeed or express milk in the workplace. However, these employers also stated that they saw little value to their business of supporting breastfeeding in the work environment. Thus, enhancement of breastfeeding opportunity in the work environment may come as a result of public and employer education but, more likely, will require some type of directive from official sources.

  5. The mechanism of mid-latitude Pi2 waves in the upper ionosphere as revealed by combined Doppler and magnetometer observations

    Directory of Open Access Journals (Sweden)

    V. A. Pilipenko

    2013-04-01

    Full Text Available The interpretation of simultaneous ionospheric Doppler sounding and ground magnetometer observations of low-latitude Pi2 waves is revised. We compare the theoretical estimates of the ionospheric Doppler velocity for the same amplitude of the ground magnetic disturbances produced by a large-scale compressional mode and an Alfvén mode. The plasma vertical displacement caused by the wave electric field is shown to be the dominating effect. Taking into account the correction of the previous paper, the observations of low-latitude Pi2 in the F layer ionosphere by Doppler sounding and SuperDARN (Super Dual Auroral Radar Network radars give consistent results. We suggest that the Doppler response to Pi2 waves is produced by the Alfvén wave component, but not the fast-mode component, whereas the ground magnetic signal is composed from both Alfvén and fast magnetosonic modes.

  6. Temporary Employment and Perceived Employability: Mediation by Impression Management

    Science.gov (United States)

    De Cuyper, Nele; De Witte, Hans

    2010-01-01

    Perceived employability (PE) has been advanced as the upcoming resource for career development, particularly for temporary workers. The question is how temporary workers become employable. Our hypothesis is that temporary workers more than permanent workers use impression management to become employable, both on the internal and the external labor…

  7. Fermi surface changes in dilute magnesium alloys: a pseudopotential band structure model

    International Nuclear Information System (INIS)

    Fung, W.K.

    1976-01-01

    The de Haas-van Alphen effect has been used to study the Fermi surface of pure magnesium and its dilute alloys containing lithium and indium. The quantum oscillations in magnetization were detected by means of a torque magnetometer in magnetic field up to 36 kilogauss and temperature range of 4.2 0 to 1.7 0 K. The results provide information on the effects of lithium and indium solutes on the Fermi surface of magnesium in changes of extremal cross sections and effective masses as well as the relaxation times associated with the orbits. The nonlocal pseudopotential model proposed by Kimball, Stark and Mueller has been fitted to the Fermi surface of magnesium and extended to include the dilute alloys, fitting all the observed de Haas-van Alphen frequencies with an accuracy of better than 1 percent. A modified rigid band interpretation including both Fermi energy and local band edge changes computed from the model, gives an overall satisfactory description of the observed frequency shifts. With the pseudo-wavefunctions provided by the nonlocal model, the relaxation times in terms of Dingle temperatures for several orbits have been predicted using Sorbello's multiple-plane-wave phase shift model. The calculation with phase shifts obtained from a model potential yields a greater anisotropy than has been observed experimentally, while a two-parameter phase shift model provides a good fit to the experimental results

  8. Quantum field theory near surfaces of discontinuity

    International Nuclear Information System (INIS)

    Onishi, H.T.

    1981-01-01

    This work deals with the problem of a quantized scalar field propagating near a surface of discontinuity. The proper time formalism is employed to express the Green's function and stress tensor as proper time integrals of a transformation function. The transformation function is calculated by a WKB approximation which exhibits the essential singularities generated by the high frequency behavior of waves propagating near the surface. Two singularities are present, the usual direct singularity and an additional reflected singularity generated by the high frequency behavior of waves reflected by the discontinuity. The stress tensor is calculated by dimensional continuation. The results are employed to analyze energy generated by the surface

  9. A theory for narrow-banded radio bursts at Uranus - MHD surface waves as an energy driver

    Science.gov (United States)

    Farrell, W. M.; Curtis, S. A.; Desch, M. D.; Lepping, R. P.

    1992-01-01

    A possible scenario for the generation of the narrow-banded radio bursts detected at Uranus by the Voyager 2 planetary radio astronomy experiment is described. In order to account for the emission burstiness which occurs on time scales of hundreds of milliseconds, it is proposed that ULF magnetic surface turbulence generated at the frontside magnetopause propagates down the open/closed field line boundary and mode-converts to kinetic Alfven waves (KAW) deep within the polar cusp. The oscillating KAW potentials then drive a transient electron stream that creates the bursty radio emission. To substantiate these ideas, Voyager 2 magnetometer measurements of enhanced ULF magnetic activity at the frontside magnetopause are shown. It is demonstrated analytically that such magnetic turbulence should mode-convert deep in the cusp at a radial distance of 3 RU.

  10. Magnetism and the interior of the moon

    Science.gov (United States)

    Dyal, P.; Parkin, C. W.; Daily, W. D.

    1974-01-01

    During the time period 1961-1972, 11 magnetometers were sent to the moon. The primary purpose of this paper is to review the results of lunar magnetometer data analysis, with emphasis on the lunar interior. Magnetic fields have been measured on the lunar surface at the Apollo 12, 14, 15, and 16 landing sites. The remanent field values at these sites are 38, 103 (maximum), 3, and 327 gammas (maximum), respectively. Simultaneous magnetic field and solar plasma pressure measurements show that the Apollo 12 and 16 remanent fields are compressed during times of high plasma dynamic pressure. Apollo 15 and 16 subsatellite magnetometers have mapped in detail the field above portions of the lunar surface and have placed an upper limit on the global permanent dipole moment. Satellite and surface measurements show strong evidence that the lunar crust is magnetized over much of the lunar globe. Magnetic fields are stronger in highland regions than in mare regions and stronger on the lunar far side than on the near side. The largest magnetic anomaly measured to date is between the craters Van de Graaff and Aitken on the lunar far side.

  11. An absolute nuclear magnetic resonance magnetometer; Magnetometre absolu a resonance magnetique nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Salvi, A [Commisariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1961-10-15

    After an introduction in which the various work undertaken since the discovery of nuclear magnetic resonance is rapidly reviewed, the author describes briefly In the first chapter three types of NMR magnetometers, giving the advantages and disadvantages of each of them and deducing from this the design of the apparatus having the greatest number of qualities Chapter II is devoted to the crossed coil nuclear oscillator which operates continuously over a wide range (800 gamma). To avoid an error due to a carrying over the frequency, the measurement is carried out using bands of 1000 {gamma}. Chapter III deals with frequency measurements. The author describes an original arrangement which makes possible the frequency-field conversion with an accuracy of {+-} 5 x 10{sup -6}, and the differential measurement between two nuclear oscillators. The report finishes with a conclusion and a few recordings. (author) [French] Apres une introduction rappelant les divers travaux effectues en resonance magnetique nucleaire depuis sa mise en evidence, l'auteur decrit sommairement dans le premier chapitre trois types de magnetometre a R.M.N. enumerant les avantages et les inconvenients de chacun a partir desquels il projet, l'appareillage reunissant le maximum de qualites. Le chapitre II est consacre a l'oscillateur nucleaire a bobines croisees permettant un fonctionnement continu dons une large plage (800 gamma). Pour eviter une erreur due a l'entrainement de frequence, la mesure s'effectue par bandes de 1000 {gamma} chacune. Le chapitre III traite la mesure de frequence. L'auteur expose un montage original permettant la traduction frequence-champ avec une precision egale a {+-} 5.10{sup -6}, et la mesure differentielle entre deux oscillateurs nucleaires. Une conclusion et quelques enregistrements terminent ce travail. (auteur)

  12. Norm Divergence, Opportunity Structure and Utilization of Self-Employed Immigrants' Qualifications

    DEFF Research Database (Denmark)

    Rezaei, Shahamak; Goli, Marco

    2009-01-01

    of immigrants' qualifications has come up to the surface of political and societal debate in Denmark. The focus of this study was challenges to that utilization. Focusing on opportunity structure and the formal and informal components of the concept and self-employment among migrants as one of the major...... the distribution of all self-employed migrants with national background in third countries with regard to (a) Business line: What they were doing and (b) Educational level: What was the level of their formal education. In order to make comparisons possible we had extracted data on 10% of self-employed with native...... sets of factors: One was the formal as well as the informal, e.g., substantially experienced by self employed immigrants, opportunity structure and the second was the type of qualifications that were required and developed in the informal economy, that produced and utilized specific comparative...

  13. Employer Branding

    DEFF Research Database (Denmark)

    Frimann, Søren; Mønsted, Bolette Rye

    2012-01-01

    Employer branding er både for den private og den offentlige sektor blevet en måde, de kan imødekomme ændrede arbejdsmarkedsvilkår og organisatoriske udfordringer i en postmoderne og globaliseret verden. Den aktuelle finanskrise har skabt nye udfordringer for organisationer i deres bestræbelser på...... at tiltrække- og fastholde attraktive medarbejdere. Men hvilken betydning har det, når Grundfos siger ”Mennesket er i fokus”, og hvad siger ”mangfoldighed” om Københavns Kommune som arbejdsplads i relation til employer branding? Er der egentlig sammenhæng mellem tankerne bag employer branding og de eksternt...... kommunikerede employer brandprodukter. Eller bliver det unikke ved arbejdspladserne ersattet af buzzwords uden substans og inddragelse af ansatte og interessenter? Artiklen har til formål at vurdere disse spørgsmål på baggrund af analyser af to cases med employer branding....

  14. Airborne gamma-ray spectrometer and magnetometer survey: Lund quadrangle, Ely quadrangle, Nevada. Volume I. Final report

    International Nuclear Information System (INIS)

    1980-01-01

    An airborne combined radiometric and magnetic survey was performed for the Department of Energy (DOE) over the area covered by the Ely and Lund 1:250,000 National Topographic Map Series (NTMS quadrangle maps). The survey was part of DOE's National Uranium Resource Evaluation (NURE) Aerial Radiometric Reconnaissance program. Data were collected by a helicopter equipped with a gamma-ray spectrometer having a large crystal volume, and a high sensitivity proton precession magnetometer. The radiometric system was calibrated at the Walker Field Calibration pads and the Lake Mead Dynamic Test range. Data quality was ensured during the survey by daily test flights and equipment checks. Radiometric data were corrected for live time, aircraft and equipment background, cosmic background, atmospheric radon, Compton scatter, and altitude dependence. The corrected data were statistically evaluated, plotted, and contoured to produce anomaly maps based on the radiometric response of individual geological units. The maps were interpreted and an anomaly interpretation map produced. Volume I contains a description of the systems used in the survey, a discussion of the calibration of the systems, the data processing procedures, the data display format, the interpretation rationale, and interpretation methodology. Volume II contains the data displays for a quadrangle and the interpretation results

  15. THE BANGLADESHI EMPLOYMENT SECTOR: EMPLOYER PERSPECTIVES CONCERNING ENGLISH PROFICIENCY

    Directory of Open Access Journals (Sweden)

    Rubina Khan

    2012-07-01

    Full Text Available Abstract: This paper presents a brief summary of a study which was carried out to investigate how employers representing major employment sectors in the Bangladeshi Industry view the skills and English proficiency level of the current employees. Opinions were also solicited on what skills are required for fresh recruits. Semi-structured interviews were conducted with 30 employers representing the major employment sectors in Bangladeshi Industry. Results revealed the importance of English as an indispensible means of communication in the Bangladeshi corporate sector and showed that the business enterprises use extensive amounts of English. It also highlighted that the existent English proficiency of the employees was far below the required proficiency level. Recommendations were made to address the gap and prepare the youth to meet the demands of the global market. Keywords: English proficiency, competency, employability skills, global literacy skills

  16. Vocational Rehabilitation and Employment program--self-employment. Final rule.

    Science.gov (United States)

    2010-01-20

    This document amends the vocational rehabilitation and employment regulations of the Department of Veterans Affairs (VA) concerning self-employment for individuals with qualifying disabilities. We are making changes to conform VA's regulations for self-employment programs for veterans, and for servicemembers awaiting discharge, to statutory provisions, including provisions limiting eligibility for certain supplies, equipment, stock, and license fees to individuals with the most severe service-connected disabilities. We are also making related changes in VA's regulations affecting eligibility for such assistance for certain veterans' children with birth defects in self-employment programs. In addition, we are amending our regulations regarding the approval authority for self-employment plans to make certain requirements less restrictive and less burdensome, to remove a vague and overly broad requirement, to make changes to reflect longstanding VA policy, and to make nonsubstantive clarifying changes.

  17. Becoming Self-Employed.

    Science.gov (United States)

    Lee, Grant; Cochran, Larry

    1997-01-01

    Explored how persons become self-employed. In critical incident interviews with five self-employed persons the critical events that assisted or hindered progress toward self-employment were listed in chronological order. In general, becoming self-employed involved establishing conditions of action that enhanced a sense of agency, thus enabling…

  18. Employer's Manual on Affirmative Action in Employment.

    Science.gov (United States)

    Kentucky State Commission on Human Rights, Frankfort.

    The express purpose of this manual is for its use by business and industry in Kentucky as an aid to eliminate discrimination. Affirmative action is defined here as a comprehensive effort by an employer designed to: employ women and minority persons where they are under-utilized; include minority persons and women in all facets of the company's…

  19. Employability Skills, Personal Qualities, and Early Employment Problems of Entry-Level Auditors: Perspectives from Employers, Lecturers, Auditors, and Students

    Science.gov (United States)

    Lim, Yet-Mee; Lee, Teck Heang; Yap, Ching Seng; Ling, Chui Ching

    2016-01-01

    The authors examine the issue of employability of university accounting students from the perspectives of accounting firm employers, junior auditors, accounting lecturers, and accounting students. Areas of investigation include perceived importance of employability skills and desirable personal qualities; and early employment problems encountered…

  20. Effects of Surface Epitope Coverage on the Sensitivity of Displacement Assays that Employ Modified Nanoparticles: Using Bisphenol A as a Model Analyte

    Directory of Open Access Journals (Sweden)

    Yang Lu

    2016-08-01

    Full Text Available With the ever-increasing use of nanoparticles in immunosensors, a fundamental study on the effect of epitope density is presented herein, with a small molecule epitope, on the performance of the displacement assay format in an enzyme-linked immunosorbent assay (ELISA. Thiolated bisphenol A (BPA functionalized gold nanoparticles (cysBPAv-AuNPs and specific anti-BPA antibodies are employed for this purpose. It is shown that the displacement of cysBPAv-AuNPs bound to the immobilized antibodies was influenced by both the avidity of bound cysBPAv-AuNPs and the concentration of free BPA to displace it. The importance of surface epitope density was that it changed the number of epitopes in close proximity to the antibody-binding site. This then influenced the avidity of cysBPAv-AuNPs bound to the immobilized antibody. Furthermore, the molar epitope concentration in an assay appears to affect the degree of antibody binding site saturation. Controlling surface epitope density of the functionalized nanoparticles and molar epitope concentration in an assay leads to a decrease of the concentration of free BPA required to displace the bound cysBPAv-AuNP, and hence better assay performance with regards to the D50 value and dynamic range in the displacement assay.

  1. Employer branding

    OpenAIRE

    Mičková, Kateřina

    2008-01-01

    The demand for qualified employees is higher then the offering, both in Czech republic and internationally. Demand for specific skills, in addition to a greater demand for workforce generally, is making employee recruitment and retention much more difficult and expensive. Employer Branding claims to be an answer to this new challenge. This international concept focuses on developing an "employer brand" - mental image of a company as an employer. To achieve this, it is necessary to demonstrate...

  2. Building Employer Capacity to Support Meaningful Employment for Persons with Developmental Disabilities: A Grounded Theory Study of Employment Support Perspectives.

    Science.gov (United States)

    Rashid, Marghalara; Hodgetts, Sandra; Nicholas, David

    2017-11-01

    To explore strategies to build employer capacity to support people with DD in meaningful employment from perspective of employment support workers. A grounded theory study was conducted with 34 employment support individuals. A theoretical sampling approach was used to identify and recruit participants from multiple sites in Ontario and Alberta. Three main themes, with seven sub-themes, emerged: (1) experiences of supporting employment finding for people with DD, (2) institutional influences on employee experiences, and (3) attitudes, assumptions and stigma. Several recommendations related to building employer capacity were offered. Our findings provide insight on specific elements and strategies that can support building employer capacity for persons with DD.

  3. Penggunaan Accelerometer dan Magnetometer pada Sistem Real Time Tracking Indoor Position untuk Studi Kasus Pada Gedung Teknik Informatika ITS

    Directory of Open Access Journals (Sweden)

    Dinar Winia Mahandhira

    2017-01-01

    Full Text Available Indoor Positioning System (IPS menggunakan perangkat mobile seperti smartphone masih menjadi permasalahan yang menantang. Seperti GPS yang tidak bekerja secara akurat di dalam gedung, IPS juga memiliki kelemahan yaitu sangat bergantung pada infrastruktur gedung seperti sinyal WiFi yang terkadang tidak tersebar secara merata di seluruh bagian gedung, sehingga membuat sistem ini terkadang tidak dapat bekerja secara optimal dan real time di setiap bagian gedung. Untuk itulah dikembangkan IPS yang menggunakan sensor gerak seperti accelerometer dan magnetometer sebagai tambahan untuk melakukan update posisi secara real time dengan mendeteksi langkah dan arah hadap pengguna saat berjalan. Pertama, posisi awal pengguna harus ditentukan terlebih dahulu misalnya menggunakan sinyal WiFi yang diproses melalui klasifikasi. Setelah posisi pengguna telah ditentukan, sistem akan mendeteksi pergerakan pengguna secara real time menggunakan sensor gerak. Uji coba dilakukan menggunakan studi kasus gedung Teknik Informatika lantai tiga. Hasil yang diberikan pada saat pengujian memberikan performa yang cukup baik dengan rata-rata persentase akurasi untuk pendeteksian langkah dan estimasi arah hadap pengguna adalah sebesar 94,8% dan 94,48%.

  4. Understanding the traction of tennis surfaces

    OpenAIRE

    Clarke, James; Carré, Matt; Richardson, Andrea; Yang, Zhijun; Damm, Loic; Dixon, Sharon

    2011-01-01

    The traction provided by a footwear-surface interaction can have an impact on player safety, performance and overall enjoyment of sport. Mechanical test methods used for the testing and categorisation of safe playing surfaces do not tend to simulate loads occurring during participation on the surface, and thus are unlikely to predict human response to the surface. For example, the pendulum system routinely employed by the International Tennis Federation (I.T.F.) utilises a standard rubber ‘fo...

  5. Flexible employment, precarious employees? Job-, employer- and institutional explanations for numerical flexibility, and its relation to precarious employment

    NARCIS (Netherlands)

    Olsthoorn, M.

    2015-01-01

    This dissertation presents a study of numerical flexibility and its relation to precarious employment in contemporary labour markets. Precarious employment is defined as the situation in which an employee has both insecure employment and insecure finances. More specifically, precarious employees are

  6. Employer Branding

    OpenAIRE

    Stroblová, Zuzana

    2017-01-01

    The aim of the Master Thesis is to describe how to build Employer Brand a company. It is based on the description of Employer Branding project of a particular company and the evaluation its process. The thesis is a case study and consists of theoretical and practical part. The theoretical part focuses on trends and changes in leadership approach, definition of Employer Branding and HR Marketing. The practical part deals with the brand building process itself, describes the outputs of the proj...

  7. A Conceptual Understanding of Employability: The Employers' View in Rwanda

    Science.gov (United States)

    Bamwesiga, Penelope Mbabazi

    2013-01-01

    Many governments believe that investing in human capital should increase citizens' employability, which is why it is often presented as a solution to the problems of knowledge-based economies and societies, rising unemployment rates and economic competiveness. The aim of this study is to understand employers' views regarding the employability of…

  8. Employer perceptions of the employability of workers in a social business.

    Science.gov (United States)

    Krupa, Terry; Howell-Moneta, Angela; Lysaght, Rosemary; Kirsh, Bonnie

    2016-06-01

    This study examined employer perceptions of employability of job candidates working in a social business for people with mental illnesses. Using an analogue research design, 99 employers participated in a simulated job hiring process, rating 2 applicants on potential to do the job, fit with workplace culture and likelihood of hiring. One job applicant worked in a social business, and the second was either (a) working in a conventional business, (b) with employment lapse attributable to mental health issues, or (c) with an unexplained employment lapse. Paired samples t tests were used to compare ratings. Qualitative data were collected regarding the rationale for rankings and a content analysis was conducted. Employer rankings were significantly higher for the applicant working in a social business compared to either applicant with an employment lapse. Employers rated the candidate working in a conventional business significantly higher compared with the candidate in a social business only on ratings of likelihood to hire. Employers valued the recency of work experience in the social business, citing concerns about risks associated with employment lapses. Their comments suggested a lack of understanding of the nature of social business. Experience in a social business appears to lessen the disadvantage of unemployment in the job hiring process, but does not appear to be ranked on par with experience in the conventional workforce. The social business sector could benefit from considering ways to publically portray these work opportunities to enhance acceptance and inclusion. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  9. Surface phonon modes of the NaI(001) crystal surface by inelastic He atom scattering

    International Nuclear Information System (INIS)

    Brug, W.P.; Chern, G.; Duan, J.; Safron, S.A.; Skofronick, J.G.; Benedek, G.

    1990-01-01

    The present theoretical treatment of the surface dynamics of ionic insulators employs the shell model with parameters obtained from bulk materials. The approach has been generally very successful in comparisons with experiment. However, most of the experimental surface dynamics work has been on the low-mass alkali halides with very little effort on higher energy modes or on the heavier alkali halides, where effects from relaxation might be important. The work of this paper explores these latter two conditions. Inelastic scattering of He atoms from the left-angle 110 right-angle NaI(001) surface has been used to obtain the acoustic S 1 Rayleigh mode, the S 6 longitudinal mode, and the S 8 crossing mode, however, no gap S 4 optical mode was seen. The results compare favorably with reported theoretical models employing both slab calculations and the Green's function method thus indicating that bulk parameters and the shell model go a long way in explaining most of the observations

  10. Surface characterization of ceramic materials

    International Nuclear Information System (INIS)

    Somorjai, G.A.; Salmeron, M.

    1976-01-01

    In recent years several techniques have become available to characterize the structure and chemical composition of surfaces of ceramic materials. These techniques utilize electron scattering and scattering of ions from surfaces. Low-energy electron diffraction is used to determine the surface structure, Auger electron spectroscopy and other techniques of electron spectroscopy (ultraviolet and photoelectron spectroscopies) are employed to determine the composition of the surface. In addition the oxidation state of surface atoms may be determined using these techniques. Ion scattering mass spectrometry and secondary ion mass spectrometry are also useful in characterizing surfaces and their reactions. These techniques, their applications and the results of recent studies are discussed. 12 figures, 52 references, 2 tables

  11. Northern South China Sea Surface Circulation and its Variability Derived by Combining Satellite Altimetry and Surface Drifter Data

    Directory of Open Access Journals (Sweden)

    N. Peter Benny

    2015-01-01

    Full Text Available The present study analyses the mean and seasonal mesoscale surface circulation of the Northern South China Sea (NSCS and determines the influence of El Niño/SouthernNiño/Southern Oscillation (ENSO. High resolution Eulerian velocity field is derived by combining the available satellite tracked surface drifter data with satellite altimetry during 1993 - 2012. The wind driven current is computed employing the weekly ocean surface mean wind fields derived from the scatterometers on board ERS 1/2, QuikSCAT and ASCAT. The derived mean velocity field exhibits strong boundary currents and broad zonal flow across NSCS. The anomalous field is quite strong in the southern part and the Seasonal circulation clearly depicts the monsoonal forcing. Eddy Kinetic Energy (EKE distribution and its spatial and temporal structures are determined employing Empirical Orthogonal Function (EOF analysis. The ENSO influence on NSCS surface circulation has been analyzed using monthly absolute geostrophic velocity fields during 1996 - 1999.

  12. Global measures of ionospheric electrodynamic activity inferred from combined incoherent scatter radar and ground magnetometer observations

    International Nuclear Information System (INIS)

    Richmond, A.D.; Kamide, Y.; Akasofu, S.I.; Alcayde, D.; Blanc, M.; De LaBeaujardiere, O.; Evans, D.S.; Foster, J.C.; Holt, J.M.; Friis-Christensen, E.; Pellinen, R.J.; Senior, C.; Zaitzev, A.N.

    1990-01-01

    An analysis of several global measures of high-latitude ionospheric electrodynamic activity is undertakn on the basis of results obtained from the Assimilative Mapping of Ionospheric Electrodynamics (AMIE) procedure applied to incoherent scatter radar and ground magnetometer observatons for January 18-19, 1984. Different global measures of electric potentials, currents, resistances, and energy transfer from the magnetosphere show temporal variations that are generally well correlated. The authors present parameterizations of thees quantities in terms of the AE index and the hemispheric power index of precipitating auroral particles. It is shown how error estimates of the mapped electric fields can be used to correct the estimation of Joule heating. Global measures of potential drop, field-aligned current, and Joule heating as obtained by the AMIE procedure are compared with similar measures presented in previous studies. Agreement is found to within the uncertainties inherent in each study. The mean potential drop through which field-aligned currents flow in closing through the ionosphere is approximately 28% of the total polar cap potential drop under all conditions during these 2 days. They note that order-of-magnitude differences can appear when comparing different global measures of total electric current flow and of effective resistances of the global circuit, so that care must be exercised in choosing characteristic values of these parameters for circuit-analogy studies of ionosphere-magnetosphere electrodynamic coupling

  13. Free surface modeling of contacting solid metal flows employing the ALE formulation

    NARCIS (Netherlands)

    van der Stelt, A.A.; Bor, Teunis Cornelis; Geijselaers, Hubertus J.M.; Akkerman, Remko; Huetink, Han; Merklein, M.; Hagenah, H.

    2012-01-01

    In this paper, a numerical problem with contacting solid metal flows is presented and solved with an arbitrary Lagrangian-Eulerian (ALE) finite element method. The problem consists of two domains which mechanically interact with each other. For this simulation a new free surface boundary condition

  14. Oxygen measurement by multimode diode lasers employing gas correlation spectroscopy.

    Science.gov (United States)

    Lou, Xiutao; Somesfalean, Gabriel; Chen, Bin; Zhang, Zhiguo

    2009-02-10

    Multimode diode laser (MDL)-based correlation spectroscopy (COSPEC) was used to measure oxygen in ambient air, thereby employing a diode laser (DL) having an emission spectrum that overlaps the oxygen absorption lines of the A band. A sensitivity of 700 ppm m was achieved with good accuracy (2%) and linearity (R(2)=0.999). For comparison, measurements of ambient oxygen were also performed by tunable DL absorption spectroscopy (TDLAS) technique employing a vertical cavity surface emitting laser. We demonstrate that, despite slightly degraded sensitivity, the MDL-based COSPEC-based oxygen sensor has the advantages of high stability, low cost, ease-of-use, and relaxed requirements in component selection and instrument buildup compared with the TDLAS-based instrument.

  15. Employment in Agribusiness.

    Science.gov (United States)

    Hilgenberg, Gene; Huston, Jane

    This curriculum guide is intended to assist persons teaching a course in employment in agribusiness. Addressed in the individual units of instruction are the following topics: employment information (training plans/agreements and wages, taxes, and fringe benefits); human relations (employer/employee/customer relations and communication skills);…

  16. Airborne gamma-ray spectrometer and magnetometer survey: Norton Bay Quadrangle (Alaska). Final report

    International Nuclear Information System (INIS)

    1980-01-01

    During the months of July, August, and September 1979, an airborne high sensitivity gamma-ray spectrometer and magnetometer survey was conducted over ten 3 0 x 1 0 NTMS quadrangles of West-Central Alaska. The results obtained over the Norton Bay Map area are discussed. The final data are presented in four different forms: on magnetic tape; on microfiche; in graphic form as profiles and histograms; and in map form as anomaly maps and flight path maps. The histograms and the multiparameter are presented with the anomaly maps and flight path map in a separate volume. A total of twenty (20) uranium anomalies have been indicated on the interpretation map. No thorium anomalies were found. The uranium anomalies are all weak and generally have only U/K or U/T expression. Often the uranium concentration within the zone is low, and generally is less than 2.5 ppM. Only zones 9, with an average of 3.0 ppM eU, and 14, with 2.6 ppm have above average uranium content. Zone 14 is also the only uranium anomaly with combined U/K and U/T ratio anomalies. No single uranium anomaly is believed to represent an economic follow-up target. The most prospective area appears to be the elongate zone of generally high uranium content, formed by the deposits of the Shaktolik group, to the east of the Ungalik conglomerate. This zone flanks an elongate area of relatively strong shallow magnetic sources, interpreted to be related to a monozonitic intrusive of which the Christmas mountain forms part. This intrusive rock contains in other neighboring areas often high thorium and uranium concentrations and may here as well served as a possible source of uranium deposits

  17. VIA Employability

    DEFF Research Database (Denmark)

    Andersen, Henrik Mariendal

    2017-01-01

    ’s realized at the entrance to the labor market and in the future career. The purpose is to find opportunities to improve employability-developing activities and to adapt it to specific needs from the students. Based on a number of qualitative interviews and personality tests of the graduates, an increased......The fact that students develop employability during their education is a key point for educational institutions and the focus on this issue has never been greater. This project looks into personal experience from VIA-graduates of "developing their employability" during the education and how it...

  18. The VHCF experimental investigation of FV520B-I with surface roughness Ry

    Science.gov (United States)

    Wang, J. L.; Zhang, Y. L.; Ding, M. C.; Zhao, Q. C.

    2018-05-01

    Different surface roughness type (Ra and Ry) has different effect on the VHCF failure and life. Ra is widely employed as the quantitative expression of the surface roughness, but there are few fatigue failure mechanism analysis and experimental study under surface roughness Ry. The VHCF experiment is conducted out using the specimen with different surface roughness values. The surface roughness Ry is employed as the major research object to investigate the relationship and distribution tendency between the Ry, fatigue life and the distance between internal inclusion and surface, and a new VHCF failure character is proposed.

  19. Potentially hazardous substances in surface waters. II. Cholinesterase inhibitors in Dutch surface waters

    NARCIS (Netherlands)

    Greve, P.A.; Freudenthal, J.; Wit, S.L.

    1972-01-01

    Several analytical methods were employed to determine the concentrations of cholinesterase inhibitors in several Dutch surface waters. An Auto-Analyzer method was used for screening purposes; thin-layer chromatography and gas-liquid chromatography-mass spectrometry were used for identification and

  20. Investigation on the micromilled surface characterization through replica technology

    DEFF Research Database (Denmark)

    Baruffi, Federico; Parenti, P.; Cacciatore, F.

    2016-01-01

    for the indirect measurement of micromilled surfaces, characterized by submicrometer roughness levels. The study assesses the performance of the replication method by measuring the surface roughness (in terms of Sa) of specifically designed micromilled flat surfaces. A 3D confocal optical microscope is employed...

  1. Which employment interview skills best predict the employability of schizophrenic patients?

    Science.gov (United States)

    Charisiou, J; Jackson, H J; Boyle, G J; Burgess, P M; Minas, I H; Joshua, S D

    1989-06-01

    To examine the effects of verbal and nonverbal interview microbehaviors and interview characteristics on employability, Simulated Employment Interviews were conducted with 46 psychiatric inpatients who each met the DSM-III criteria for a diagnosis of schizophrenia. Each interview was videotaped and shown to two raters, who generated independent ratings for six microbehaviors (eye-contact, facial gestures, body posture, verbal content, voice volume, and length of speech) and six subject characteristics (motivation, self-confidence, ability to communicate, manifest adjustment, manifest intelligence and overall interview skill). A panel of three Commonwealth Employment Service psychologists viewed the same videotaped interviews and generated employability ratings. Verbal and nonverbal microbehaviors were relatively independent while subject characteristics were highly interdependent. Microbehaviors and characteristics correlated at a high level. Of the 12 interview microbehaviors and characteristics, manifest adjustment and ability to communicate accounted for 64% of the total variance in predicting employability. Interviewees who were perceived as behaving in an adjusted manner and as being good communicators were rated as more employable.

  2. Identification of Optimum Magnetic Behavior of NanoCrystalline CmFeAl Type Heusler Alloy Powders Using Response Surface Methodology

    Science.gov (United States)

    Srivastava, Y.; Srivastava, S.; Boriwal, L.

    2016-09-01

    Mechanical alloying is a novelistic solid state process that has received considerable attention due to many advantages over other conventional processes. In the present work, Co2FeAl healer alloy powder, prepared successfully from premix basic powders of Cobalt (Co), Iron (Fe) and Aluminum (Al) in stoichiometric of 60Co-26Fe-14Al (weight %) by novelistic mechano-chemical route. Magnetic properties of mechanically alloyed powders were characterized by vibrating sample magnetometer (VSM). 2 factor 5 level design matrix was applied to experiment process. Experimental results were used for response surface methodology. Interaction between the input process parameters and the response has been established with the help of regression analysis. Further analysis of variance technique was applied to check the adequacy of developed model and significance of process parameters. Test case study was performed with those parameters, which was not selected for main experimentation but range was same. Response surface methodology, the process parameters must be optimized to obtain improved magnetic properties. Further optimum process parameters were identified using numerical and graphical optimization techniques.

  3. 20 CFR 404.1003 - Employment.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Employment. 404.1003 Section 404.1003...- ) Employment, Wages, Self-Employment, and Self-Employment Income Employment § 404.1003 Employment. Employment....1010. Section 404.1004 states the general rule on the kinds of work covered as employment. Exceptions...

  4. Measurement of the terrestrial magnetic field and its anomalies; Mesures du champ magnetique terrestre et de ses anomalies

    Energy Technology Data Exchange (ETDEWEB)

    Duret, D.

    1994-12-31

    After a presentation of the terrestrial magnetic field and its various anomalies, the different types of magnetometers commonly used are reviewed with their characteristics and performances: scalar magnetometers (free precession and continuous polarization proton magnetometers, dynamic polarization proton magnetometers, optical pumping magnetometers, electronic resonance scalar magnetometers (without pumping)); vectorial magnetometers (flux gate magnetometers, induction magnetometers, suspended magnet magnetometers, superconducting magnetometers, integrated magnetometers, resonance directional magnetometers). The magnetometry market and applications are discussed. 20 figs., 9 tabs., 72 refs.

  5. Measurement of the terrestrial magnetic field and its anomalies

    International Nuclear Information System (INIS)

    Duret, D.

    1994-01-01

    After a presentation of the terrestrial magnetic field and its various anomalies, the different types of magnetometers commonly used are reviewed with their characteristics and performances: scalar magnetometers (free precession and continuous polarization proton magnetometers, dynamic polarization proton magnetometers, optical pumping magnetometers, electronic resonance scalar magnetometers (without pumping)); vectorial magnetometers (flux gate magnetometers, induction magnetometers, suspended magnet magnetometers, superconducting magnetometers, integrated magnetometers, resonance directional magnetometers). The magnetometry market and applications are discussed. 20 figs., 9 tabs., 72 refs

  6. An initial investigation of the long-term trends in the fluxgate magnetometer (FGM) calibration parameters on the four Cluster spacecraft

    Science.gov (United States)

    Alconcel, L. N. S.; Fox, P.; Brown, P.; Oddy, T. M.; Lucek, E. L.; Carr, C. M.

    2014-07-01

    Over the course of more than 10 years in operation, the calibration parameters of the outboard fluxgate magnetometer (FGM) sensors on the four Cluster spacecraft are shown to be remarkably stable. The parameters are refined on the ground during the rigorous FGM calibration process performed for the Cluster Active Archive (CAA). Fluctuations in some parameters show some correlation with trends in the sensor temperature (orbit position). The parameters, particularly the offsets, of the spacecraft 1 (C1) sensor have undergone more long-term drift than those of the other spacecraft (C2, C3 and C4) sensors. Some potentially anomalous calibration parameters have been identified and will require further investigation in future. However, the observed long-term stability demonstrated in this initial study gives confidence in the accuracy of the Cluster magnetic field data. For the most sensitive ranges of the FGM instrument, the offset drift is typically 0.2 nT per year in each sensor on C1 and negligible on C2, C3 and C4.

  7. Employer Toolkit.

    Science.gov (United States)

    Thuli, Kelli J.; Hong, Esther

    This document consists of two guides intended for either employers or service providers involved in school to work partnerships for students with disabilities. "Tools for Service Providers" is intended to be used for training local-level providers who are developing school to work linkages with employers. Following an introduction, this…

  8. Employment and employment conditions in the current economic crisis in Croatia

    Directory of Open Access Journals (Sweden)

    Goran Vukšić

    2014-06-01

    Full Text Available The goal of this research is to analyze developments in employment and employment characteristics during the current crisis in Croatia. The main findings can be summarized as follows: (1 The primary (aggregate mode of adjustment to the crisis was a decline in employment. There are, however, considerable differences in adjustment patterns across economic activities. (2 During the crisis, jobs were lost in the, more dynamic, private sector, while the number of jobs in the public sector (entities in state ownership slightly increased. (3 Economic activities with comparatively larger shares of women in employment have experienced fewer employment cuts and the aggregate employment share of women rose during the crisis, especially in activities with a larger share of public sector workers.(4 There has been a declining share of younger workers during the crisis, justifying policy actions to facilitate their employment. (5 Employees with comparatively lower educational attainment face severe challenges in the labor market, which is a longer term trend, not specific to the crisis period. There are indications that this group of employees enjoys a higher level of protection in the public sector. (6 Analysis also shows a rising significance of more flexible forms of employment: increasing shares of fixed term employees (during the last two observed years, and of part time workers. (7 Working hours do not exhibit any strong trends specific to the crisis, except for the diminishing number of overtime hours per worker.

  9. Cohesion and coordination effects on transition metal surface energies

    Science.gov (United States)

    Ruvireta, Judit; Vega, Lorena; Viñes, Francesc

    2017-10-01

    Here we explore the accuracy of Stefan equation and broken-bond model semiempirical approaches to obtain surface energies on transition metals. Cohesive factors are accounted for either via the vaporization enthalpies, as proposed in Stefan equation, or via cohesive energies, as employed in the broken-bond model. Coordination effects are considered including the saturation degree, as suggested in Stefan equation, employing Coordination Numbers (CN), or as the ratio of broken bonds, according to the bond-cutting model, considering as well the square root dependency of the bond strength on CN. Further, generalized coordination numbers CN bar are contemplated as well, exploring a total number of 12 semiempirical formulations on the three most densely packed surfaces of 3d, 4d, and 5d Transition Metals (TMs) displaying face-centered cubic (fcc), body-centered cubic (bcc), or hexagonal close-packed (hcp) crystallographic structures. Estimates are compared to available experimental surface energies obtained extrapolated to zero temperature. Results reveal that Stefan formula cohesive and coordination dependencies are only qualitative suited, but unadvised for quantitative discussion, as surface energies are highly overestimated, favoring in addition the stability of under-coordinated surfaces. Broken-bond cohesion and coordination dependencies are a suited basis for quantitative comparison, where square-root dependencies on CN to account for bond weakening are sensibly worse. An analysis using Wulff shaped averaged surface energies suggests the employment of broken-bond model using CN to gain surface energies for TMs, likely applicable to other metals.

  10. Elastic layer under axisymmetric indentation and surface energy effects

    Science.gov (United States)

    Intarit, Pong-in; Senjuntichai, Teerapong; Rungamornrat, Jaroon

    2018-04-01

    In this paper, a continuum-based approach is adopted to investigate the contact problem of an elastic layer with finite thickness and rigid base subjected to axisymmetric indentation with the consideration of surface energy effects. A complete Gurtin-Murdoch surface elasticity is employed to consider the influence of surface stresses. The indentation problem of a rigid frictionless punch with arbitrary axisymmetric profiles is formulated by employing the displacement Green's functions, derived with the aid of Hankel integral transform technique. The problem is solved by assuming the contact pressure distribution in terms of a linear combination of admissible functions and undetermined coefficients. Those coefficients are then obtained by employing a collocation technique and an efficient numerical quadrature scheme. The accuracy of proposed solution technique is verified by comparing with existing solutions for rigid indentation on an elastic half-space. Selected numerical results for the indenters with flat-ended cylindrical and paraboloidal punch profiles are presented to portray the influence of surface energy effects on elastic fields of the finite layer. It is found that the presence of surface stresses renders the layer stiffer, and the size-dependent behavior of elastic fields is observed in the present solutions. In addition, the surface energy effects become more pronounced with smaller contact area; thus, the influence of surface energy cannot be ignored in the analysis of indentation problem especially when the indenter size is very small such as in the case of nanoindentation.

  11. Employers' attitudes to employment of people with epilepsy: still the same old story?

    Science.gov (United States)

    Jacoby, Ann; Gorry, Joanne; Baker, Gus A

    2005-12-01

    One area of life quality known to be compromised by having epilepsy is employment, and one factor contributing to the employment problems of people with epilepsy (PWE) is employer attitudes. Much research on this topic is now outdated and given the changing legal, medical, and social contexts in which PWE live, we therefore reexamined employer attitudes in the United Kingdom. A mail survey of a random sample of U.K. companies selected to be representative of the 14 U.K. economic regions and proportional to the number of employees. The overall response rate was 41% (n = 204). Twenty-six percent of respondents reported having experience of employing PWE. Sixteen percent considered that there were no jobs in their company suitable for PWE; 21% thought employing PWE would be "a major issue." Employers were uniformly of the view that PWE, even when in remission, should disclose their condition to a prospective employer. Seizure severity, frequency, and controllability were all considered important features of epilepsy in the context of employment. Epilepsy created high concern to around half of employers, including the likelihood of it being linked to a work-related accident. Employers were willing to make accommodations for PWE, in particular job sharing, temporary reassignment of duties, and flexible working hours. Attitudes to employment of PWE were influenced by company size and type and previous experience of doing so. We conclude that it is still the same old story for employers' attitudes toward PWE, though happily for PWE, with some room for optimism.

  12. A facile and flexible process of β-cyclodextrin grafted on Fe3O4 magnetic nanoparticles and host-guest inclusion studies

    International Nuclear Information System (INIS)

    Zhu Jie; He Jiang; Du Xiaoyan; Lu Ruihua; Huang Lizhen; Ge Xia

    2011-01-01

    In this study, a kind of novel surface-functionalized magnetic nanoparticles was fabricated by the Fe 3 O 4 nanoparticles surface modification with mono-6-deoxy-6-(p-tolylsulfonyl)-cyclodextrin (6-TsO-β-CD), which were employed to interact with uric acid and their behavior was investigated by electrochemical methods. The architecture has been characterized by powder X-ray diffraction (XRD), Fourier transform infrared spectra (FT-IR), transmission electron microscopy (TEM), and thermogravimetric analysis (TGA), which confirmed that cyclodextrins have been effectively functionalized on the surface of Fe 3 O 4 nanoparticles. The analyses of vibration sample magnetometer (VSM) verified that the nanoparticles owned good magnetic property. The grafted β-cyclodextrin on the Fe3O4 nanoparticles contributed to as a modified electrode for detecting uric acid with cyclic voltammograms. Electrochemical results revealed that the new materials could exhibit excellent molecules recognition ability and show high electrochemical response. The new nanoparticles simultaneously had unique properties of magnetic nanoparticles and cyclodextrins through combining their individual distinct advantages.

  13. Surface chemistry and tribology of MEMS.

    Science.gov (United States)

    Maboudian, Roya; Carraro, Carlo

    2004-01-01

    The microscopic length scale and high surface-to-volume ratio, characteristic of microelectro-mechanical systems (MEMS), dictate that surface properties are of paramount importance. This review deals with the effects of surface chemical treatments on tribological properties (adhesion, friction, and wear) of MEMS devices. After a brief review of materials and processes that are utilized in MEMS technology, the relevant tribological and chemical issues are discussed. Various MEMS microinstruments are discussed, which are commonly employed to perform adhesion, friction, and wear measurements. The effects of different surface treatments on the reported tribological properties are discussed.

  14. Building professionalism and employability skills: embedding employer engagement within first-year computing modules

    Science.gov (United States)

    Hanna, Philip; Allen, Angela; Kane, Russell; Anderson, Neil; McGowan, Aidan; Collins, Matthew; Hutchison, Malcolm

    2015-07-01

    This paper outlines a means of improving the employability skills of first-year university students through a closely integrated model of employer engagement within computer science modules. The outlined approach illustrates how employability skills, including communication, teamwork and time management skills, can be contextualised in a manner that directly relates to student learning but can still be linked forward into employment. The paper tests the premise that developing employability skills early within the curriculum will result in improved student engagement and learning within later modules. The paper concludes that embedding employer participation within first-year models can help relate a distant notion of employability into something of more immediate relevance in terms of how students can best approach learning. Further, by enhancing employability skills early within the curriculum, it becomes possible to improve academic attainment within later modules.

  15. Covalent Surface Modifications of Carbon Nanotubes.

    Energy Technology Data Exchange (ETDEWEB)

    Pavia Sanders, Adriana [Sandia National Lab. (SNL-CA), Livermore, CA (United States); O' Bryan, Greg [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2017-07-01

    A report meant to document the chemistries investigated by the author for covalent surface modification of CNTs. Oxidation, cycloaddition, and radical reactions were explored to determine their success at covalently altering the CNT surface. Characterization through infrared spectroscopy, Raman spectroscopy, and thermo gravimetric analysis was performed in order to determine the success of the chemistries employed. This report is not exhaustive and was performed for CNT surface modification exploration as it pertains to the "Next Gen" project.

  16. Concept of self-employment

    OpenAIRE

    Startienė, Gražina; Remeikienė, Rita; Dumčiuvienė, Daiva

    2010-01-01

    The article deals with the theories that explain the growth of self-employment and help to determine the presumptions of the self-employment growth. Self-employment theories are classified to several groups, i.e. the economic and sociological-psychological as well as the “push” and “pull” theories. Economic theories of self-employment interpret financial motives of the person to pursue own business, while sociologicalpsychological theories of self-employment determine non-financial objectives...

  17. Analysis of ULF Waves During Substorms Observed in the Ionosphere from the Dayside Ground Magnetometer and in the Solar Wind from the Satellite

    Science.gov (United States)

    Streltsov, A. V.; Alimaganbetov, M.

    2017-12-01

    Magnetospheric substorm is one of the most interesting and complicated phenomena of solar-terrestrial interactions. Despite numerous theoretical and experimental studies conducted during last 50 years, its several important phenomena are not completely understood yet. One of them are intense, ultra-low-frequency (from 0.5 mHz to 100 mHz), electromagnetic pulsations which are always observed during the substorms with the ground-based magnetometers and radars at high latitudes. These waves have the largest amplitudes in the power spectral densities during substorms. Hence, they are the most effective drivers of such mechanisms as high-latitude ionosphere energization, ion outflow production, formation of plasma density cavities, etc. In our study, we focus on the waves with frequencies 0.5-1.0 mHz, which is the lowest part of the frequency spectra observed during the substorm. The questions of what phenomena cause these oscillations and what are their spatiotemporal properties are among the most important ones about the physics of the substorm. To answer these questions, we analyzed disturbances of the magnetic field obtained from the two sources for the period from October 2015 to November 2016 during several substorms. One source is the fluxgate magnetometer in Poker Flat, Alaska. Another is the NASA Advanced Composite Explorer satellite in the Lagrangian L1 point that detects most of the solar wind from the Sun. The goal of our project is to find correlations between the disturbances observed from these sources, which will be a strong argument that the solar wind has a strong influence on the electromagnetic coupling between the ionosphere and magnetosphere of the Earth during the substorms. We observed 48 substorms during the abovementioned period. Our findings show that 1) the dominant frequency of the large-amplitude ULF waves observed during the substorms is 1 mHz or less; and 2) the same frequencies are frequently observed in the waves detected from the both

  18. Detection and delineation of waste trenches by geophysical methods at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Selfridge, R.J.

    1987-01-01

    Detection and delineation of waste trenches at hazardous waste sites are needed before actual implementation of site corrective measures. In a field study conducted in Solid Waste Storage Area 4 (SWSA4) at Oak Ridge National Laboratory (ORNL), surface geophysical techniques were used to assist in the delineation of waste trenches. A magnetometer/gradiometer survey was used to detect ferrous metals buried at the site. An electromagnetic ground conductivity survey was used to measure the electrical conductivity of the subsurface and aided in supporting the magnetometer/gradiometer results. Results from the two techniques were complimentary and easily integrated into a final interpretation. The reliability, efficiency, and worker safety benefits of these techniques offer a nondestructive surface technique for locating buried waste trenches

  19. An analysis of the procedural components of supported employment programs associated with employment outcomes.

    OpenAIRE

    McDonnell, J; Nofs, D; Hardman, M; Chambless, C

    1989-01-01

    This study examined the relation between the procedural components of supported employment programs and employment outcomes for 120 individuals with disabilities. These individuals were involved in supported employment programs established through the Utah Supported Employment Project. The results suggest that successful implementation of supported employment services led to ongoing employment of study participants in community work sites, increased wages, and ongoing opportunities for worker...

  20. Nanoscale spin sensing in artificial cell membranes

    International Nuclear Information System (INIS)

    Simpson David

    2014-01-01

    The use of the nitrogen-vacancy (NV) centre in diamond as a single spin sensor or magnetometer has attracted considerable interest in recent years because of its unique combination of sensitivity, nanoscale resolution, and optical initialisation and readout at room temperature. Nanodiamonds in particular hold great promise as an optical magnetometer probe for bio applications. In this work we employ nanodiamonds containing single NV spins to detect freely diffusing Mn2+ ions by detecting changes in the transverse relaxation time (T2) of the single spin probe. We also report the detection of gadolinium spin labels present in an artificial cell membrane by measuring changes in the longitudinal relaxation time (T1) of the probe. (author)

  1. Diamond surface functionalization with biomimicry - Amine surface tether and thiol moiety for electrochemical sensors

    Science.gov (United States)

    Sund, James B.; Causey, Corey P.; Wolter, Scott D.; Parker, Charles B.; Stoner, Brian R.; Toone, Eric J.; Glass, Jeffrey T.

    2014-05-01

    The surface of conducting diamond was functionalized with a terminal thiol group that is capable of binding and detecting nitrogen-oxygen species. The functionalization process employed multiple steps starting with doped diamond films grown by plasma enhanced chemical vapor deposition followed by hydrogen termination and photochemical attachment of a chemically protected amine alkene. The surface tether was deprotected to reveal the amine functionality, which enabled the tether to be extended with surface chemistry to add a terminal thiol moiety for electrochemical sensing applications. Each step of the process was validated using X-ray photoelectron spectroscopy analysis.

  2. Graduates', University Lecturers' and Employers' Perceptions towards Employability Skills

    Science.gov (United States)

    Wickramasinghe, Vathsala; Perera, Lasantha

    2010-01-01

    Purpose: The purpose of this study is to explore employability skills that employers, university lecturers and graduates value to bring to the workplace, when graduates are applying for entry-level graduate jobs in the field of computer science in Sri Lanka. Design/methodology/approach: A total of three samples were selected for this exploratory…

  3. Surface science techniques

    CERN Document Server

    Bracco, Gianangelo

    2013-01-01

    The book describes the experimental techniques employed to study surfaces and interfaces. The emphasis is on the experimental method. Therefore all chapters start with an introduction of the scientific problem, the theory necessary to understand how the technique works and how to understand the results. Descriptions of real experimental setups, experimental results at different systems are given to show both the strength and the limits of the technique. In a final part the new developments and possible extensions of the techniques are presented. The included techniques provide microscopic as well as macroscopic information. They cover most of the techniques used in surface science.

  4. Reduction of surface erosion in fusion reactors

    International Nuclear Information System (INIS)

    Rossing, T.D.; Das, S.K.; Kaminsky, M.

    1976-01-01

    Some of the major processes leading to surface erosion in fusion reactors are reviewed briefly, including blistering by implanted gas, sputtering by ions, atoms, and neutrons, and vaporization by local heating. Surface erosion affects the structural integrity and limits the lifetime of reactor components exposed to plasma radiation. In addition, some of the processes leading to surface erosion also cause the release of plasma contaminants. Methods proposed to reduce surface erosion have included control of surface temperature, selection of materials with a favorable microstructure, chemical and mechanical treatment of surfaces, and employment of protective surface coatings, wall liners, and divertors. The advantages and disadvantages of some of these methods are discussed

  5. A positioning and data logging system for surface geophysical surveys

    International Nuclear Information System (INIS)

    Nyquist, J.E.; Blair, M.S.

    1988-01-01

    The Ultrasonic Ranging and Data System (USRADS) developed at ORNL is being adapted to work with two commercially available geophysical instruments: a magnetometer and an EM31 terrain conductivity meter. Geophysical surveys have proven an important preliminary step in investigating hazardous waste sites. Magnetometers and terrain conductivity meters are used to locate buried drums, trenches, conductive contaminant plumes and map regional changes in geology. About half the field time of a typical geophysical investigation is spent surveying the position of the grid points at which the measurements will be made. Additional time is lost and errors may be made recording instrument values in field notebooks and transcribing the data to a computer. Developed for gamma radiation surveys, the USRAD system keeps track of the surveyor's position automatically by triangulating on an ultrasonic transmitter carried in a backpack. The backpack also contains a radio transmitter that sends the instrument's reading coincident with the ultrasonic pulse. The surveyor's position and the instrument's reading are recorded by a portable computer which can plot the data to check the survey's progress. Electronic files are stored in a form compatible with AutoCAD to speed report writing. 7 refs., 3 figs

  6. PERCEIVED EMPLOYABILITY OF UNIVERSITY STUDENTS INSOUTH AFRICA. IS IT RELATED TO EMPLOYABILITY SKILLS?

    Directory of Open Access Journals (Sweden)

    HA Koloba

    2017-01-01

    Full Text Available The on-going changes in the workplace demand that the current andfuturegeneration of workers should be well trained since their knowledge, skills andpositive attitude are essential to cope with the demands of the modern world. Forthis reason, university students, who are the future generation of the labour force,need to gear themselves up for a tough journey in the prevailing economicconditions. Previous research has revealed that the possession of employabilityskills has the potential to ascertain successful careers for students, as they will bemore employable during their working life. Therefore, this study aimed toinvestigate the relationship between employability skills of university studentsand their perceptions of employability. A quantitative research approach wasadopted. A self-administered questionnairewas distributed among universitystudents at four universities in South Africa and data were analysed from 485participants. Exploratory factor analysis was used to establish the factors.Correlation analysis was used to establish whether there is any relationshipbetween employability skills and perceived employability among universitystudents in South Africa. The majority of students regard themselves aspossessing employability skills. Furthermore, the findings revealed that there is apositive relationship between students’ employability skills and their perceptionsof employability. The conclusion drawn from this finding is that universitystudents, with the appropriate knowledge and skills acquired from different fieldsof study, are likely to have higher self-confidence and may, therefore, influencethe state of the labour market. It is recommended that employability skills shouldbe incorporated into the curriculum in order to enhance employability of students

  7. Employability Skills Valued by Employers as Important for Entry-Level Employees with and without Disabilities

    Science.gov (United States)

    Ju, Song; Zhang, Dalun; Pacha, Jacqueline

    2012-01-01

    Individuals with disabilities face persistent challenges in gaining meaningful employment. One of the barriers to successful employment is a lack of employability skills. The purpose of this study was to identify employability skills that employers value as being important and to examine whether employers have different expectations for…

  8. Surface Patterning Using Diazonium Ink Filled Nanopipette.

    Science.gov (United States)

    Zhou, Min; Yu, Yun; Blanchard, Pierre-Yves; Mirkin, Michael V

    2015-11-03

    Molecular grafting of diazonium is a widely employed surface modification technique. Local electrografting of this species is a promising approach to surface doping and related properties tailoring. The instability of diazonium cation complicates this process, so that this species was generated in situ in many reported studies. In this Article, we report the egress transfer of aryl diazonium cation across the liquid/liquid interface supported at the nanopipette tip that can be used for controlled delivery this species to the external aqueous phase for local substrate patterning. An aryl diazonium salt was prepared with weakly coordinating and lipophilic tetrakis(pentafluorophenyl)borate anion stable as a solid and soluble in low polarity media. The chemically stable solution of this salt in 1,2-dichloroethane can be used as "diazonium ink". The ink-filled nanopipette was employed as a tip in the scanning electrochemical microscope (SECM) for surface patterning with the spatial resolution controlled by the pipette orifice radius and a few nanometers film thickness. The submicrometer-size grafted spots produced on the HOPG surface were located and imaged with the atomic force microscope (AFM).

  9. The effect of organisational context variables on employer attitudes toward employability of ex-offenders.

    Science.gov (United States)

    Lukies, John; Graffam, Joseph; Shinkfield, Alison J

    2011-05-01

    The authors tested the premise that organisational context variables (i.e., size of organisation, industry type, location, and respondent's position in organisation) had significant effects on employer (N = 596) attitudes toward employability of ex-offenders. They also examined whether organisational context variables had an equivalent effect on employer attitudes to that of job-seeker criminal history and employer personal characteristics (e.g., respondent age and gender). Using linear regression (HLM 6.02a), organisational context variables were shown to have a significant effect on employer attitudes. In addition, organisational context variables had a significantly greater effect on employer attitudes than did employer personal characteristics. However, job-seeker criminal history contributed more to respondent ratings of ex-offender employability than did organisational context variables. The finding that judgements of employability are influenced by organisational context variables has implications for future research relevant to reintegration. Stakeholder attitudes toward the reintegration success of ex-offenders may be generally influenced by context variables.

  10. Employee to employer communication skills: balancing cancer treatment and employment.

    Science.gov (United States)

    Brown, Richard F; Owens, Myra; Bradley, Cathy

    2013-02-01

    Cancer patients face difficulties in accessing legally mandated benefits and accommodations when they return to the workplace. Poor employer-employee communication inflates these difficulties. Although proven methods to facilitate physician-patient communication exist, these have not been applied to the workplace. Thus, we aimed to assess the feasibility and utility of applying these methods to educate patients about their workplace rights and provide them with communication skills training to aid their conversations with their employers. A DVD was produced to educate patients and facilitate workplace communication. Participants consisted of 28 solid tumor cancer patients (14 women and 14 men) who completed primary cancer treatment in the past 12 months and were employed at the time of diagnosis. Participants watched a communication skills training DVD and completed a telephone interview. The interview elicited information about workplace experiences and evaluation of the DVD training program. The physician-patient communication skills training model utilized was successfully translated to the employer-employee setting. All but one participant found the DVD useful and easy to understand and indicated a high degree of confidence in using the communication skills to help them ask for workplace accommodations. All participants agreed that it would help newly diagnosed patients in discussions with their employers. Our data provides promising preliminary evidence that patient communication skills training can be applied to the workplace setting and is a welcomed aid to newly diagnosed cancer patients in their discussions with employers regarding the impact of treatment on their work performance and needs for accommodations. Copyright © 2011 John Wiley & Sons, Ltd.

  11. Gauging the Association of Employability Skills and Being Employable among Students

    OpenAIRE

    Fayeq Ali Ali

    2017-01-01

    The current study is to measure the employability skills of students and to assess how employability skills are perceived in higher educations. Three sets of employability skills have been used such as Basic Academic Skills, Personal Qualities and High-Order Thinking. A questionnaire has been developed and distributed among students in universities, Erbil, Kurdistan. Respondents’ opinions were assessed using a Likert scale analysis that shows opinions between two extremes of levels of agreeme...

  12. Reducing Employment Insecurity

    Directory of Open Access Journals (Sweden)

    Florence Lebert

    2016-10-01

    Full Text Available The perception of job insecurity is known to be a stressful condition for employees. Less is known about employment insecurity and the ways employees and their families deal with it. This study investigates whether participation in further training is a strategy that employees adopt to reduce perceived employment insecurity. As participation in further training is often costly and time-consuming, we assume that the family context is of importance for the decision to take part in further training. To take account of possible self-selection, we apply a propensity score matching procedure on longitudinal data from the Swiss Household Panel (2004-2013. Three main findings can be emphasized: first, participation in further training is not a strategy adopted particularly by employees who perceive high employment insecurity as they are less likely to train than their secure counterparts. Second, even though further training is not a strategy that is actively adopted, employees who train subsequently report lower levels of perceived employment insecurity. Third, the family context indeed influences the likelihood to train: partnered employees are more likely to train and preschool-aged children act as a constraint on women’s but enhance men’s participation in further training. Yet, in the context of high perceived employment insecurity, children generally reduce their parents’ likelihood to train as the parents may turn to other strategies that reduce perceived employment insecurity.

  13. 77 FR 76074 - Advisory Committee on Veterans' Employment, Training and Employer Outreach (ACVETEO): Meeting

    Science.gov (United States)

    2012-12-26

    ... Department of Labor's Veterans' Employment and Training Services' (VETS) core programs and new initiatives... DEPARTMENT OF LABOR Advisory Committee on Veterans' Employment, Training and Employer Outreach (ACVETEO): Meeting AGENCY: Veterans' Employment and Training Service, Labor. ACTION: Notice of open meeting...

  14. Health status of anthracite surface coal miners

    International Nuclear Information System (INIS)

    Amandus, H.E.; Petersen, M.R.; Richards, T.B.

    1989-01-01

    In 1984-1985, medical examinations consisting of a chest radiograph, spirometry test, and questionnaire on work history, respiratory symptoms, and smoking history were administered to 1,061 white males who were employed at 31 coal cleaning plants and strip coal mines in the anthracite coal region of northeastern Pennsylvania. The prevalence of radiographic evidence of International Labour Office (ILO) category 1 or higher small opacities was 4.5% in 516 men who had never been employed in a dusty job other than in surface coal mining. Among these 516 workers, all 4 cases of ILO radiographic category 2 or 3 rounded opacities and 1 case of large opacities had been employed as a highwall drill operator or helper. The prevalence of category 1 or higher opacities increased with tenure as a highwall drill operator or helper (2.7% for 0 y, 6.5% for 1-9 yr, 25.0% for 10-19 y, and 55.6% for greater than or equal to 20 y drilling). Radiographic evidence of small rounded opacities, dyspnea, and decreases in FEV1.0, FVC, and peak flow were significantly related to tenure at drilling operations after adjusting for age, height, cigarette smoking status, and exposures in dusty jobs other than in surface coal mining. However, tenure in coal cleansing plants and other surface coal mine jobs were not related to significant health effects. The apparent excess prevalence of radiographic small rounded opacities in anthracite surface coal mine drillers suggests that quartz exposures have been increased. Average respirable quartz concentrations at surface coal mine drilling operations should be evaluated to determine whether exposures are within existing standards, and dust exposures should be controlled

  15. Employer Child Care Surviving and Thriving: Employer Child Care Trend Report #17

    Science.gov (United States)

    Neugebauer, Roger

    2010-01-01

    Today employer child care is accepted as standard benefit for employees and nearly all Fortune 500 companies have gotten involved. The current recession threatened to halt the growth of employer child care as companies consolidated, cut back, and folded. However, in reviewing the status of employer child care for this trend report, it appears that…

  16. Perspectives of employability skills

    OpenAIRE

    ANNE LOUISE NEWTON

    2017-01-01

    The study investigated the different perspectives held by young people, employers and policy makers around Employability Skills and it examined how young people learnt these skills. This study draws young peoples’ perspectives into the research around Employability Skills and highlights the way in which social and cultural capital mediate their development. The research points to a model to re-vision employability skills which recognises the many ways in which they are learnt, over time a...

  17. Employer-Sponsored Health Insurance: Are Employers Good Agents for Their Employees?

    OpenAIRE

    Peele, Pamela B.; Lave, Judith R.; Black, Jeanne T.; Evans III, John H.

    2000-01-01

    Employers in the United States provide many welfare-type benefits, such as life insurance, disability insurance, health insurance, and pensions, to their employees. Employers can be viewed as performing an agency role in purchasing pension, health, and other welfare benefits for their employees. An exploration of their competence in this role as agents for their employees indicates that large employers are very helpful to their employees in this arena. They seem to contribute to individual em...

  18. Employment Composition: A Study of Australian Employment Growth, 2002–2006

    OpenAIRE

    Jeremy Lawson; Crystal Ossolinski

    2010-01-01

    This paper uses data from the Household, Income and Labour Dynamics in Australia (HILDA) Survey to examine whether there was a change in employment rates for people with ‘low employment’ characteristics between 2002 and 2006, which was a period of strong employment growth. In particular, it estimates the relationships between employment and personal and household characteristics using a binomial logit model, with a comparison of the coefficients in 2002 and 2006 providing tentative evidence o...

  19. Packing parameters effect on injection molding of polypropylene nanostructured surfaces

    DEFF Research Database (Denmark)

    Calaon, Matteo; Tosello, Guido; Hansen, Hans Nørgaard

    2012-01-01

    having a diameter of 500 nm was employed. The tool insert surface was produced using chemical-based-batch techniques such aluminum anodization and nickel electroplating. During the injection molding process, polypropylene (PP) was employed as material and packing phase parameters (packing time, packing...

  20. Suppression of the dayside magnetopause surface modes

    Directory of Open Access Journals (Sweden)

    Pilipenko V.A.

    2017-12-01

    Full Text Available Magnetopause surface eigenmodes were suggested as a potential source of dayside high-latitude broadband pulsations in the Pc5-6 band (frequency about 1–2 mHz. However, the search for a ground signature of these modes has not provided encouraging results. The comparison of multi-instrument data from Svalbard with the latitudinal structure of Pc5-6 pulsations, recorded by magnetometers covering near-cusp latitudes, has shown that often the latitudinal maximum of pulsation power occurs about 2–3° deeper in the magnetosphere than the dayside open-closed field line boundary (OCB. The OCB proxy was determined from SuperDARN radar data as the equatorward boundary of enhanced width of a return radio signal. The OCB-ULF correspondence is further examined by comparing the latitudinal profile of the near-noon pulsation power with the equatorward edge of the auroral red emission from the meridian scanning photometer. In most analyzed events, the “epicenter” of Pc5-6 power is at 1–2° lower latitude than the optical OCB proxy. Therefore, the dayside Pc5-6 pulsations cannot be associated with the ground image of the magnetopause surface modes or with oscillations of the last field line. A lack of ground response to these modes beneath the ionospheric projection of OCB seems puzzling. As a possible explanation, we suggest that a high variability of the outer magnetosphere near the magnetopause region may suppress the excitation efficiency. To quantify this hypothesis, we consider a driven field line resonator terminated by conjugate ionospheres with stochastic fluctuations of its eigenfrequency. A solution of this problem predicts a substantial deterioration of resonant properties of MHD resonator even under a relatively low level of background fluctuations. This effect may explain why there is no ground response to magnetopause surface modes or oscillations of the last field line at the OCB latitude, but it can be seen at somewhat lower latitudes

  1. Surface States and Effective Surface Area on Photoluminescent P-Type Porous Silicon

    Science.gov (United States)

    Weisz, S. Z.; Porras, A. Ramirez; Resto, O.; Goldstein, Y.; Many, A.; Savir, E.

    1997-01-01

    The present study is motivated by the possibility of utilizing porous silicon for spectral sensors. Pulse measurements on the porous-Si/electrolyte system are employed to determine the surface effective area and the surface-state density at various stages of the anodization process used to produce the porous material. Such measurements were combined with studies of the photoluminescence spectra. These spectra were found to shift progressively to the blue as a function of anodization time. The luminescence intensity increases initially with anodization time, reaches a maximum and then decreases with further anodization. The surface state density, on the other hand, increases with anodization time from an initial value of about 2 x 10(exp 12)/sq cm surface to about 1013 sq cm for the anodized surface. This value is attained already after -2 min anodization and upon further anodization remains fairly constant. In parallel, the effective surface area increases by a factor of 10-30. This behavior is markedly different from the one observed previously for n-type porous Si.

  2. The effects of the Employment Tax Incentive on South African employment

    OpenAIRE

    Ebrahim, Amina; Leibbrandt, Murray; Ranchhod, Vimal

    2017-01-01

    South Africa's Employment Tax Incentive, launched in 2014, aimed to address low youth employment by reducing the cost of hiring young workers. We make use of anonymized tax administrative data from the 2012-2015 tax years to examine the effect of the Incentive on youth employment. We match firms claiming the subsidy with similar firms not claiming the subsidy and observe their hiring behaviour before and after the implementation of the policy. We find no statistically significant impact on yo...

  3. Multiresolution molecular mechanics: Surface effects in nanoscale materials

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Qingcheng, E-mail: qiy9@pitt.edu; To, Albert C., E-mail: albertto@pitt.edu

    2017-05-01

    Surface effects have been observed to contribute significantly to the mechanical response of nanoscale structures. The newly proposed energy-based coarse-grained atomistic method Multiresolution Molecular Mechanics (MMM) (Yang, To (2015), ) is applied to capture surface effect for nanosized structures by designing a surface summation rule SR{sup S} within the framework of MMM. Combined with previously proposed bulk summation rule SR{sup B}, the MMM summation rule SR{sup MMM} is completed. SR{sup S} and SR{sup B} are consistently formed within SR{sup MMM} for general finite element shape functions. Analogous to quadrature rules in finite element method (FEM), the key idea to the good performance of SR{sup MMM} lies in that the order or distribution of energy for coarse-grained atomistic model is mathematically derived such that the number, position and weight of quadrature-type (sampling) atoms can be determined. Mathematically, the derived energy distribution of surface area is different from that of bulk region. Physically, the difference is due to the fact that surface atoms lack neighboring bonding. As such, SR{sup S} and SR{sup B} are employed for surface and bulk domains, respectively. Two- and three-dimensional numerical examples using the respective 4-node bilinear quadrilateral, 8-node quadratic quadrilateral and 8-node hexahedral meshes are employed to verify and validate the proposed approach. It is shown that MMM with SR{sup MMM} accurately captures corner, edge and surface effects with less 0.3% degrees of freedom of the original atomistic system, compared against full atomistic simulation. The effectiveness of SR{sup MMM} with respect to high order element is also demonstrated by employing the 8-node quadratic quadrilateral to solve a beam bending problem considering surface effect. In addition, the introduced sampling error with SR{sup MMM} that is analogous to numerical integration error with quadrature rule in FEM is very small. - Highlights:

  4. Youth employment in Egypt

    OpenAIRE

    Eekelen, Willem van; De Luca, Loretta; Ismail, Magwa

    2001-01-01

    Examines economic and social factors affecting youth employment in Egypt and describes three national programmes for the promotion of youth employment based on human resources development, direct job creation and support in self-employment and enterprise creation. Describes one public-private project in each case.

  5. [Detection of surface EMG signal using active electrode].

    Science.gov (United States)

    He, Qinghua; Peng, Chenglin; Wu, Baoming; Wang, He

    2003-09-01

    Research of surface electromyogram(EMG) signal is important in rehabilitation medicine, sport medicine and clinical diagnosis, accurate detection of signal is the base of quantitative analysis of surface EMG signal. In this article were discussed how to reduce possible noise in the detection of surface EMG. Considerations on the design of electrode unit were presented. Instrumentation amplifier AD620 was employed to design a bipolar active electrode for use in surface EMG detection. The experiments showed that active electrode could be used to improve signal/noise ratio, reduce noise and detect surface EMG signal effectively.

  6. Validity and reliability of smartphone magnetometer-based goniometer evaluation of shoulder abduction--A pilot study.

    Science.gov (United States)

    Johnson, Linda B; Sumner, Sean; Duong, Tina; Yan, Posu; Bajcsy, Ruzena; Abresch, R Ted; de Bie, Evan; Han, Jay J

    2015-12-01

    Goniometers are commonly used by physical therapists to measure range-of-motion (ROM) in the musculoskeletal system. These measurements are used to assist in diagnosis and to help monitor treatment efficacy. With newly emerging technologies, smartphone-based applications are being explored for measuring joint angles and movement. This pilot study investigates the intra- and inter-rater reliability as well as concurrent validity of a newly-developed smartphone magnetometer-based goniometer (MG) application for measuring passive shoulder abduction in both sitting and supine positions, and compare against the traditional universal goniometer (UG). This is a comparative study with repeated measurement design. Three physical therapists utilized both the smartphone MG and a traditional UG to measure various angles of passive shoulder abduction in a healthy subject, whose shoulder was positioned in eight different positions with pre-determined degree of abduction while seated or supine. Each therapist was blinded to the measured angles. Concordance correlation coefficients (CCCs), Bland-Altman plotting methods, and Analysis of Variance (ANOVA) were used for statistical analyses. Both traditional UG and smartphone MG were reliable in repeated measures of standardized joint angle positions (average CCC > 0.997) with similar variability in both measurement tools (standard deviation (SD) ± 4°). Agreement between the UG and MG measurements was greater than 0.99 in all positions. Our results show that the smartphone MG has equivalent reliability compared to the traditional UG when measuring passive shoulder abduction ROM. With concordant measures and comparable reliability to the UG, the newly developed MG application shows potential as a useful tool to assess joint angles. Published by Elsevier Ltd.

  7. Grain size measurements by ultrasonic Rayleigh surface waves

    International Nuclear Information System (INIS)

    Palanichamy, P.; Jayakumar, T.

    1996-01-01

    The use of Rayleigh surface waves to determine average grain size nondestructively in an austenitic stainless steel AISI type 316 stainless is discussed. Two commercial type 4MHz frequency surface wave transducers, one as transmitter and the other as receiver were employed for the measurement of surface wave amplitudes. Relative amplitudes of the Rayleigh surface waves were correlated with the metallographically obtained grain sizes. Results indicate that surface/sub-surface average grain sizes of AISI type 316 austenitic stainless steel can be estimated with a confidence level of more than 80% in the grain size range 30-170 μm. (author)

  8. Employment protection

    OpenAIRE

    Stefano Scarpetta

    2014-01-01

    Laws on hiring and firing are intended to protect workers from unfair behavior by employers, to counter imperfections in financial markets that limit workers’ ability to insure themselves against job loss, and to preserve firm-specific human capital. But by imposing costs on firms’ adaptation to changes in demand and technology, employment protection legislation may reduce not only job destruction but also job creation, hindering the efficient allocation of labor and productivity growth....

  9. The Netherlands: self-employed

    NARCIS (Netherlands)

    Houtman, I.L.D.

    2009-01-01

    This is the national contribution to the CAR on self-employed workers in the Netherlands. In this national contribution information is provided on self-employed workers in relation to (1) legal provisions and social security, (2) recent trends in self-employment with no employees, (3) collective

  10. Employment relations, flexibility and risk

    DEFF Research Database (Denmark)

    Jensen, Carsten Strøby

    Employment relations literature often distinguishes between social democratic/corporatist models of employment relations and liberal models of employment relations as they are seen as opposite or at least different ways of organizing labor markets. They are often characterized as having very...... different risk profiles in terms of relationships between employees, employers, and the state. Low levels of labor market regulation very often characterize the liberal models of employment relations as we know them from, for instance, the USA and the UK. This means that employment conditions are very often...... insecure and that the burden of unemployment risk mostly lies with the employees rather than the employer. Corporatist – or social democratic – employment relations models are, in contrast to the liberal models, often characterized by stricter regulation of the labor market and by high standards...

  11. Methods for Finding Legacy Wells in Large Areas

    Energy Technology Data Exchange (ETDEWEB)

    Hammack, Richard W. [National Energy Technology Lab. (NETL), Pittsburgh, PA, (United States); Veloski, Garret A. [National Energy Technology Lab. (NETL), Pittsburgh, PA, (United States); Hodges, D. Greg [Fugro Airborne Surveys, Mississauga, ON (Canada); White, Jr., Curt M. [National Energy Technology Lab. (NETL), Pittsburgh, PA, (United States)

    2016-06-16

    United States. When abandoned, many wells were not adequately sealed and now provide a potential conduit for the vertical movement of liquids and gases. Today, groundwater aquifers can be contaminated by surface pollutants flowing down wells or by deep, saline water diffusing upwards. Likewise, natural gas, carbon dioxide (CO2), or radon can travel upwards via these wells to endanger structures or human health on the surface. Recently, the need to find and plug wells has become critical with the advent of carbon dioxide injection into geologic formations for enhanced oil recovery (EOR) or carbon storage. The potential for natural gas or brine leakage through existing wells has also been raised as a concern in regions where shale resources are hydraulically fractured for hydrocarbon recovery. In this study, the National Energy Technology Laboratory (NETL) updated existing, effective well finding techniques to be able to survey large areas quickly using helicopter or ground-vehicle-mounted magnetometers, combined with mobile methane detection. For this study, magnetic data were collected using airborne and ground vehicles equipped with two boom-mounted magnetometers, or on foot using a hand-held magnetometer with a single sensor. Data processing techniques were employed to accentuate well-casing-type magnetic signatures. To locate wells with no magnetic signature (wells where the steel well casing had been removed), the team monitored for anomalous concentrations of methane, which could indicate migration of volatile compounds from deeper sedimentary strata along a well or fracture pathway. Methane measurements were obtained using the ALPIS DIfferential Absorption Lidar (DIAL) sensor for helicopter surveys and the Apogee leak detection system (LDS) for ground surveys. These methods were evaluated at a 100-year-old oilfield in Wyoming, where a helicopter magnetic survey accurately located 93% of visible wells. In addition, 20% of the wells found by the survey were

  12. Methods for Finding Legacy Wells in Large Areas

    Energy Technology Data Exchange (ETDEWEB)

    Hammack, Richard [National Energy Technology Lab. (NETL), Pittsburgh, PA, (United States); Veloski, Garret [National Energy Technology Lab. (NETL), Pittsburgh, PA, (United States); Hodges, D. Greg [Fugro Airborne Surveys, Mississauga, ON (Canada); White, Jr., Charles E. [National Energy Technology Lab. (NETL), Pittsburgh, PA, (United States)

    2016-06-16

    More than 10 million wells have been drilled during 150 years of oil and gas production in the United States. When abandoned, many wells were not adequately sealed and now provide a potential conduit for the vertical movement of liquids and gases. Today, groundwater aquifers can be contaminated by surface pollutants flowing down wells or by deep, saline water diffusing upwards. Likewise, natural gas, carbon dioxide (CO2), or radon can travel upwards via these wells to endanger structures or human health on the surface. Recently, the need to find and plug wells has become critical with the advent of carbon dioxide injection into geologic formations for enhanced oil recovery (EOR) or carbon storage. The potential for natural gas or brine leakage through existing wells has also been raised as a concern in regions where shale resources are hydraulically fractured for hydrocarbon recovery. In this study, the National Energy Technology Laboratory (NETL) updated existing, effective well finding techniques to be able to survey large areas quickly using helicopter or ground-vehicle-mounted magnetometers, combined with mobile methane detection. For this study, magnetic data were collected using airborne and ground vehicles equipped with two boom-mounted magnetometers, or on foot using a hand-held magnetometer with a single sensor. Data processing techniques were employed to accentuate well-casing-type magnetic signatures. To locate wells with no magnetic signature (wells where the steel well casing had been removed), the team monitored for anomalous concentrations of methane, which could indicate migration of volatile compounds from deeper sedimentary strata along a well or fracture pathway. Methane measurements were obtained using the ALPIS DIfferential Absorption Lidar (DIAL) sensor for helicopter surveys and the Apogee leak detection system (LDS) for ground surveys. These methods were evaluated at a 100-year-old oilfield in Wyoming, where a helicopter magnetic

  13. Social innovation in employment

    NARCIS (Netherlands)

    Oeij, P.R.A.; Torre, W. van der; Santoclides, M.E

    2017-01-01

    This policy brief on Social Innovation of Employment informs on an inventory of challenges and policy recommendations based on the Case Study Report of Employment and on the Second Policy Foresight Workshop of Employment. A ‘paradigm shift’ is needed in the mind-set of policymakers. ‘Traditional’

  14. Thin film surface reconstruction analysis

    Energy Technology Data Exchange (ETDEWEB)

    Imperatori, P [CNR, Monterotondo Stazione, Rome (Italy). Istituto di Chimica dei materiali

    1996-09-01

    The study of the atomic structure of surfaces and interfaces is a fundamental step in the knowledge and the development of new materials. Among the several surface-sensitive techniques employed to characterise the atomic arrangements, grazing incidence x-ray diffraction (GIXD) is one of the most powerful. With a simple data treatment, based on the kinematical theory, and using the classical methods of x-ray bulk structure determination, it gives the atomic positions of atoms at a surface or an interface and the atomic displacements of subsurface layers for a complete determination of the structure. In this paper the main features of the technique will be briefly reviewed and selected of application to semiconductor and metal surfaces will be discussed.

  15. Smoothing optimization of supporting quadratic surfaces with Zernike polynomials

    Science.gov (United States)

    Zhang, Hang; Lu, Jiandong; Liu, Rui; Ma, Peifu

    2018-03-01

    A new optimization method to get a smooth freeform optical surface from an initial surface generated by the supporting quadratic method (SQM) is proposed. To smooth the initial surface, a 9-vertex system from the neighbor quadratic surface and the Zernike polynomials are employed to establish a linear equation system. A local optimized surface to the 9-vertex system can be build by solving the equations. Finally, a continuous smooth optimization surface is constructed by stitching the above algorithm on the whole initial surface. The spot corresponding to the optimized surface is no longer discrete pixels but a continuous distribution.

  16. How Full is Full Employment? : How Tools and Not Theory Explained Full Employment

    NARCIS (Netherlands)

    Rodenburg, P.

    2016-01-01

    The post-war debate on full employment policy was blurred and unclear since the concept of full employment itself was theoretically unclear and un-operational. Unable to theoretically determine the unemployment level of full employment, economists tried to find more empirically based ways to

  17. Employer attractiveness from a generational perspective: Implications for employer branding

    Directory of Open Access Journals (Sweden)

    Germano Glufke Reis

    2016-03-01

    Full Text Available ABSTRACT This study aimed to identify the employer attractiveness factors prioritized by different generations: Baby Boomers, Generation X, and Generation Y. The survey was conducted with a sample of 937 professionals, working in various areas and companies, most of them were managers and had a high education level. The Employer Attractiveness Scale proposed by Berthon et al. (2005 was adopted and the results indicate that, when choosing a company, the generations under study have specific features regarding the attractiveness attributes they prioritize. It was also observed that Generation Y discriminates and ranks such attributes more clearly than the others. Possible implications for employer branding and research limitations are discussed at the end of the article.

  18. Business/Employers Influenza Toolkit

    Centers for Disease Control (CDC) Podcasts

    This podcast promotes the "Make It Your Business To Fight The Flu" toolkit for Businesses and Employers. The toolkit provides information and recommended strategies to help businesses and employers promote the seasonal flu vaccine. Additionally, employers will find flyers, posters, and other materials to post and distribute in the workplace.

  19. Dirac equation on a curved surface

    Energy Technology Data Exchange (ETDEWEB)

    Brandt, F.T., E-mail: fbrandt@usp.br; Sánchez-Monroy, J.A., E-mail: antosan@usp.br

    2016-09-07

    The dynamics of Dirac particles confined to a curved surface is examined employing the thin-layer method. We perform a perturbative expansion to first-order and split the Dirac field into normal and tangential components to the surface. In contrast to the known behavior of second order equations like Schrödinger, Maxwell and Klein–Gordon, we find that there is no geometric potential for the Dirac equation on a surface. This implies that the non-relativistic limit does not commute with the thin-layer method. Although this problem can be overcome when second-order terms are retained in the perturbative expansion, this would preclude the decoupling of the normal and tangential degrees of freedom. Therefore, we propose to introduce a first-order term which rescues the non-relativistic limit and also clarifies the effect of the intrinsic and extrinsic curvatures on the dynamics of the Dirac particles. - Highlights: • The thin-layer method is employed to derive the Dirac equation on a curved surface. • A geometric potential is absent at least to first-order in the perturbative expansion. • The effects of the extrinsic curvature are included to rescue the non-relativistic limit. • The resulting Dirac equation is consistent with the Heisenberg uncertainty principle.

  20. Diamond surface functionalization with biomimicry – Amine surface tether and thiol moiety for electrochemical sensors

    Energy Technology Data Exchange (ETDEWEB)

    Sund, James B., E-mail: jim@jamessund.com [Department of Electrical and Computer Engineering, Duke University, Durham, NC (United States); Causey, Corey P. [Departments of Chemistry and Biochemistry, Duke University, Durham, NC (United States); Wolter, Scott D. [Department of Physics, Elon University, Elon, NC 27244 (United States); Parker, Charles B., E-mail: charles.parker@duke.edu [Department of Electrical and Computer Engineering, Duke University, Durham, NC (United States); Stoner, Brian R. [Department of Electrical and Computer Engineering, Duke University, Durham, NC (United States); Research Triangle Institute (RTI) International, Research Triangle Park, NC (United States); Toone, Eric J. [Departments of Chemistry and Biochemistry, Duke University, Durham, NC (United States); Glass, Jeffrey T. [Department of Electrical and Computer Engineering, Duke University, Durham, NC (United States)

    2014-05-01

    Highlights: • Diamond surfaces were functionalized with organic molecules using a novel approach. • Used biomimicry to select a molecule to bind NO, similar to the human body. • Molecular orbital theory predicted the molecule-analyte oxidation behavior. • A thiol moiety was attached to an amine surface tether on the diamond surface. • XPS analysis verified each surface functionalization step. - Abstract: The surface of conducting diamond was functionalized with a terminal thiol group that is capable of binding and detecting nitrogen–oxygen species. The functionalization process employed multiple steps starting with doped diamond films grown by plasma enhanced chemical vapor deposition followed by hydrogen termination and photochemical attachment of a chemically protected amine alkene. The surface tether was deprotected to reveal the amine functionality, which enabled the tether to be extended with surface chemistry to add a terminal thiol moiety for electrochemical sensing applications. Each step of the process was validated using X-ray photoelectron spectroscopy analysis.