WorldWideScience

Sample records for surface magnetic probes

  1. Probing surface magnetism with ion beams

    International Nuclear Information System (INIS)

    Winter, H.

    2007-01-01

    Ion beams can be used to probe magnetic properties of surfaces by a variety of different methods. Important features of these methods are related to trajectories of atomic projectiles scattered from the surface of a solid target and to the electronic interaction mechanisms in the surface region. Both items provide under specific conditions a high sensitivity for the detection of magnetic properties in the region at the topmost layer of surface atoms. This holds in particular for scattering under planar surface channeling conditions, where under grazing impact atoms or ions are reflected specularly from the surface without penetration into the subsurface region. Two different types of methods are employed based on the detection of the spin polarization of emitted or captured electrons and on spin blocking effects for capture into atomic terms. These techniques allow one to probe the long range and short range magnetic order in the surface region

  2. A new capacitive/resistive probe method for studying magnetic surfaces

    International Nuclear Information System (INIS)

    Kitajima, Sumio; Takayama, Masakazu; Zama, Tatsuya; Takaya, Kazuhiro; Takeuchi, Nobunao; Watanabe, Hiroshige

    1991-01-01

    A new capacitive/resistive probe method for mapping the magnetic surfaces from resistance or capacitance between a magnetic surface and a vacuum vessel was developed and tested. Those resistances and capacitances can be regarded as components of a simple electrical bridge circuit. This method exploits electrical transient response of the bridge circuit for a square pulse. From equiresistance or equicapacitance points, the magnetic surface structure can be deduced. Measurements on the Tohoku University Heliac, which is a small-size standard heliac, show good agreement with numerical calculations. This method is particularly useful for pulse-operated machines. (author)

  3. Radioactive Probes on Ferromagnetic Surfaces

    CERN Multimedia

    2002-01-01

    On the (broad) basis of our studies of nonmagnetic radioactive probe atoms on magnetic surfaces and at interfaces, we propose to investigate the magnetic interaction of magnetic probe atoms with their immediate environment, in particular of rare earth (RE) elements positioned on and in ferromagnetic surfaces. The preparation and analysis of the structural properties of such samples will be performed in the UHV chamber HYDRA at the HMI/Berlin. For the investigations of the magnetic properties of RE atoms on surfaces Perturbed Angular Correlation (PAC) measurements and Mössbauer Spectroscopy (MS) in the UHV chamber ASPIC (Apparatus for Surface Physics and Interfaces at CERN) are proposed.

  4. Curling probe measurement of a large-volume pulsed plasma with surface magnetic confinement

    Science.gov (United States)

    Pandey, A.; Tashiro, H.; Sakakibara, W.; Nakamura, K.; Sugai, H.

    2016-12-01

    A curling probe (CP) based on microwave resonance is applied to the measurement of electron density in a pulsed DC glow discharge under surface magnetic confinement (SMC) provided by a number of permanent magnets on a chamber wall. Owing to the SMC effects, a 1 m scale large-volume plasma is generated by a relatively low voltage (~1 kV) at low pressure (~1 Pa) in various gases (Ar, CH4, and C2H2). Temporal variation of the electron density is measured for pulse frequency f  =  0.5-25 kHz for various discharge-on times (T ON) with a high resolution time (~0.2 µs), using the on-point mode. In general, the electron density starts to increase at time t  =  0 after turn-on of the discharge voltage, reaches peak density at t  =  T ON, and then decreases after turn-off. The peak electron density is observed to increase with the pulse frequency f for constant T ON owing to the residual plasma. This dependence is successfully formulated using a semi-empirical model. The spatio-temporal evolution of the cathode sheath in the pulsed discharge is revealed by a 1 m long movable CP. The measured thickness of the high-voltage cathode fall in a steady state coincides with the value of the so-called Child-Langmuir sheath.

  5. Response of Magnetic Force Microscopy Probes under AC Magnetic Field

    Science.gov (United States)

    Sungthong, A.; Ruksasakchai, P.; Saengkaew, K.; Cheowanish, I.; Damrongsak, B.

    2017-09-01

    In this paper, magnetic force microscopy (MFM) probes with different coating materials were characterized under AC magnetic field. A perpendicular magnetic write head similar to those used in hard disk drives was employed as the AC magnetic field generator. In order to measure a response of MFM probes to AC magnetic field, a MFM probe under test was scanned, at a scan height of 10 nm, across the surface of the magnetic write head. During MFM imaging, the write head was biased by a sufficient magnitude of AC current, approximately 30 mA. A spectral analysis for a frequency sweep from 1 kHz to 100 MHz was extracted from post-processing MFM images. As expected, a MFM probe coated with hard magnetic alloys, i.e. FePt, has the lowest response to AC magnetic fields. MFM probes coated with soft magnetic alloys, i.e. NiFe and NiCoCr, have a relatively high and flat response across the frequency range. Ni coated MFM probe has the highest response to AC magnetic fields. In addition, CoCr and NiCo coated MFM probes show lower response than NiFe and NiCoCr probes at low frequencies; however, theirs response to AC magnetic field increase for the AC magnetic field with a frequency above 50 kHz. This can be implied that those MFM probes are a good candidate for being used to study the high-frequency performance of perpendicular magnetic write heads. Noting that response of all MFM probes significantly decreased when driven frequencies above 1 MHz due to the limitation of the hardware, i.e. response of quadrant photodiode and op-amp in a pre-amplifier.

  6. Probing fine magnetic particles with neutron scattering

    International Nuclear Information System (INIS)

    Pynn, R.

    1991-01-01

    Because thermal neutrons are scattered both by nuclei and by unpaired electrons, they provide an ideal probe for studying the atomic and magnetic structures of fine-grained magnetic materials, including nanocrystalline solids, thin epitaxial layers, and colloidal suspensions of magnetic particles, known as ferrofluids. Diffraction, surface reflection, and small angle neutron scattering (SANS) are the techniques used. With the exception of surface reflection, these methods are described in this article. The combination of SANS with refractive-index matching and neutron polarisation analysis is particularly powerful because it allows the magnetic and atomic structures to be determined independently. This technique has been used to study both dilute and concentrated ferrofluid suspensions of relatively monodisperse cobalt particles, subjected to a series of applied magnetic fields. The size of the cobalt particle core and the surrounding surfactant layer were determined. The measured interparticle structure factor agrees well with a recent theory that allows correlations in binary mixtures of magnetic particles to be calculated in the case of complete magnetic alignment. When one of the species in such a binary mixture is a nonmagnetic, cyclindrical macromolecule, application of a magnetic field leads to some degree of alignment of the nonmagnetic species. This result has been demonstrated with tobacco mosaic virus suspended in a water-based ferrofluid

  7. Magnetism and magnetic materials probed with neutron scattering

    Energy Technology Data Exchange (ETDEWEB)

    Velthuis, S.G.E. te, E-mail: tevelthuis@anl.gov [Materials Science Division, Argonne National Laboratory, 9700 S Cass Ave, Argonne, IL 60439 (United States); Pappas, C. [Faculty of Applied Sciences, Delft University of Technology, Mekelweg 15, NL-2629JB Delft (Netherlands)

    2014-01-15

    Neutron scattering techniques are becoming increasingly accessible to a broader range of scientific communities, in part due to the onset of next-generation, high-power spallation sources, high-performance, sophisticated instruments and data analysis tools. These technical advances also advantageously impact research into magnetism and magnetic materials, where neutrons play a major role. In this Current Perspective series, the achievements and future prospects of elastic and inelastic neutron scattering, polarized neutron reflectometry, small angle neutron scattering, and neutron imaging, are highlighted as they apply to research into magnetic frustration, superconductivity and magnetism at the nanoscale. - Highlights: • Introduction to Current Perspective series titled Magnetism and Magnetic Materials probed with Neutron Scattering. • Elastic and inelastic neutron scattering in systems with magnetic frustration and superconductivity. • Small angle neutron scattering and polarized neutron reflectometry in studying magnetism at the nanoscale. • Imaging of magnetic fields and domains.

  8. Magnetism and magnetic materials probed with neutron scattering

    International Nuclear Information System (INIS)

    Velthuis, S.G.E. te; Pappas, C.

    2014-01-01

    Neutron scattering techniques are becoming increasingly accessible to a broader range of scientific communities, in part due to the onset of next-generation, high-power spallation sources, high-performance, sophisticated instruments and data analysis tools. These technical advances also advantageously impact research into magnetism and magnetic materials, where neutrons play a major role. In this Current Perspective series, the achievements and future prospects of elastic and inelastic neutron scattering, polarized neutron reflectometry, small angle neutron scattering, and neutron imaging, are highlighted as they apply to research into magnetic frustration, superconductivity and magnetism at the nanoscale. - Highlights: • Introduction to Current Perspective series titled Magnetism and Magnetic Materials probed with Neutron Scattering. • Elastic and inelastic neutron scattering in systems with magnetic frustration and superconductivity. • Small angle neutron scattering and polarized neutron reflectometry in studying magnetism at the nanoscale. • Imaging of magnetic fields and domains

  9. Characteristics of langmuir probe in low temperature, weakly magnetized plasmas

    International Nuclear Information System (INIS)

    Wu Liqi; Liu Wandong; Xie Jinlin; Yu Zhi; Lan Tao; Ouyang Liang; Wang Yi; Zhao Kai

    2003-01-01

    The systematic Langmuir probe measurements for a weakly magnetized plasma have been carried out in the Linear Magnetized Plasma Device for different magnetic fields. By comparing the ion current density of probes with different sizes, the sheath thickness can be evaluated. It is found that while the ratio of cylindrical probe's dimension to ion Larmor radius is not more than 2, the model of probe for non-magnetized plasma is still applicable

  10. Surface charge measurement using an electrostatic probe

    DEFF Research Database (Denmark)

    Crichton, George C; McAllister, Iain Wilson

    1998-01-01

    During the 1960s, the first measurements of charge on dielectric surfaces using simple electrostatic probes were reported. However it is only within the last 10 years that a proper understanding of the probe response has been developed. This situation arose as a consequence of the earlier studies...

  11. Calibration of NS value of magnetic probe on EAST

    International Nuclear Information System (INIS)

    Sun Jiuyu; Shen Biao; Liu Guangjun; Sun Youwen; Qian Jinping; Li Shi; Xiao Bingjia; Chen Dalong; Shi Tonghui

    2014-01-01

    Based on the basic principle of measuring magnetic field by magnetic probe, a solenoid calibration system is constructed by a long solenoid, alternating current power, standard probe and data acquisition system in order to get the accurate magnetic field data. The NS value of magnetic probe on EAST is calibrated accurately by the solenoid calibration system and the data of the calibration is analysed. The obtained results are what we expected and provide the prerequisite for accurate magnetic field measurement in tokamak. (authors)

  12. Design of magnetic probe coils in the EAST tokamak

    International Nuclear Information System (INIS)

    Xi Weibin; Wu Songtao; Shen Biao; Wan Baonan; Song Yuntao

    2008-01-01

    A detailed description of measurement theory, magnetic probes geometry, fabrication, calibration, and frequency response is introduced. The calibration error of the magnetic probe and the frequency response of Mirnov coil are given. The EAST experiments show that magnetic sensors could provide sufficient information for machine operation and plasma control. (authors)

  13. Evaluation of Flat Surface Temperature Probes

    Science.gov (United States)

    Beges, G.; Rudman, M.; Drnovsek, J.

    2011-01-01

    The objective of this paper is elaboration of elements related to metrological analysis in the field of surface temperature measurement. Surface temperature measurements are applicable in many fields. As examples, safety testing of electrical appliances and a pharmaceutical production line represent case studies for surface temperature measurements. In both cases correctness of the result of the surface temperature has an influence on final product safety and quality and thus conformity with specifications. This paper deals with the differences of flat surface temperature probes in measuring the surface temperature. For the purpose of safety testing of electrical appliances, surface temperature measurements are very important for safety of the user. General requirements are presented in European standards, which support requirements in European directives, e.g., European Low Voltage Directive 2006/95/EC and pharmaceutical requirements, which are introduced in official state legislation. This paper introduces a comparison of temperature measurements of an attached thermocouple on the measured surface and measurement with flat surface temperature probes. As a heat generator, a so called temperature artifact is used. It consists of an aluminum plate with an incorporated electrical heating element with very good temperature stability in the central part. The probes and thermocouple were applied with different forces to the surface in horizontal and vertical positions. The reference temperature was measured by a J-type fine-wire (0.2 mm) thermocouple. Two probes were homemade according to requirements in the European standard EN 60335-2-9/A12, one with a fine-wire (0.2 mm) thermocouple and one with 0.5mm of thermocouple wire diameter. Additional commercially available probes were compared. Differences between probes due to thermal conditions caused by application of the probe were found. Therefore, it can happen that measurements are performed with improper equipment or

  14. Surface sampling concentration and reaction probe

    Science.gov (United States)

    Van Berkel, Gary J; Elnaggar, Mariam S

    2013-07-16

    A method of analyzing a chemical composition of a specimen is described. The method can include providing a probe comprising an outer capillary tube and an inner capillary tube disposed co-axially within the outer capillary tube, where the inner and outer capillary tubes define a solvent capillary and a sampling capillary in fluid communication with one another at a distal end of the probe; contacting a target site on a surface of a specimen with a solvent in fluid communication with the probe; maintaining a plug volume proximate a solvent-specimen interface, wherein the plug volume is in fluid communication with the probe; draining plug sampling fluid from the plug volume through the sampling capillary; and analyzing a chemical composition of the plug sampling fluid with an analytical instrument. A system for performing the method is also described.

  15. Surface Effects in Magnetic Nanoparticles

    CERN Document Server

    Fiorani, Dino

    2005-01-01

    This volume is a collection of articles on different approaches to the investigation of surface effects on nanosized magnetic materials, with special emphasis on magnetic nanoparticles. The book aims to provide an overview of progress in the understanding of surface properties and surface driven effects in magnetic nanoparticles through recent results of different modeling, simulation, and experimental investigations.

  16. MTRAP: The Magnetic Transition Region Probe

    Science.gov (United States)

    Davis, J. M.; West, E. A.; Moore, R. L.; Gary, G. A.; Kobayashi, K.; Oberright, J. F.; Evans, D. C.; Wood, H. J.; Saba, J. L. R.; Alexander, D.

    2005-01-01

    The Magnetic Transition Region Probe is a space telescope designed to measure the magnetic field at several heights and temperatures in the solar atmosphere, providing observations spanning the chromospheric region where the field is expected to become force free. The primary goal is to provide an early warning system (hours to days) for solar energetic particle events that pose a serious hazard to astronauts in deep space and to understand the source regions of these particles. The required magnetic field data consist of simultaneous circular and linear polarization measurements in several spectral lines over the wavelength range from 150 to 855 nm. Because the observations are photon limited an optical telescope with a large (>18sq m) collecting area is required. To keep the heat dissipation problem manageable we have chosen to implement MTRAP with six separate Gregorian telescopes, each with approx. 3 sq m collecting area, that are brought to a common focus. The large field of view (5 x 5 arcmin(sup 2)) and angular resolution (0.025 arcsec pixels) require large detector arrays and, because of the requirements on signal to noise (10(exp 3)), pixels with large full well depths to reduce the readout time and improve the temporal resolution. The optical and engineering considerations that have gone into the development of a concept that meets MTRAP's requirements are described.

  17. Drift-free equilibrium reconstruction using magnetic probes

    International Nuclear Information System (INIS)

    Lister, J.B.; Saint-Laurent, F.; Moreau, Ph.; Lukash, V.E.

    2004-01-01

    Tore Supra has recently demonstrated the existence of a new effect, causing magnetic diagnostic drift and not previously taken into consideration, which is slight rotation of the magnetic probes by thermo-mechanical distortion during 300 second pulses absorbing more than 1 GJ into the plasma, resulting in time-dependent pick-up of the toroidal magnetic field. The Tore Supra control system tracks these offsets and displaces the last closed flux surface from its reference location. This new effect of long high-power pulses has the properties of a drift, generating a slowly evolving unmeasured offset to the integrated magnetic signals. For this reason, we have decided to take another look at methods of reconstructing an offset-free equilibrium from magnetic diagnostics, whereas most proposed approaches to drift compensation rely on non-magnetic, non-integrated measurements of plasma emission or reflectometry. We note that a similar approach was tested on HT-7 using the induction in the poloidal field coils as the sole measurement of the radial position, modulating in a similar way. Although this present work uses magnetic diagnostics, we are extending this idea to include the vertical position and the deformation of highly shaped plasmas

  18. Bunker probe: A plasma potential probe almost insensitive to its orientation with the magnetic field.

    Science.gov (United States)

    Costea, S; Fonda, B; Kovačič, J; Gyergyek, T; Schneider, B S; Schrittwieser, R; Ionita, C

    2016-05-01

    Due to their ability to suppress a large part of the electron current and thus measuring directly the plasma potential, ion sensitive probes have begun to be widely tested and used in fusion devices. For these probes to work, almost perfect alignment with the total magnetic field is necessary. This condition cannot always be fulfilled due to the curvature of magnetic fields, complex magnetic structure, or magnetic field reconnection. In this perspective, we have developed a plasma potential probe (named Bunker probe) based on the principle of the ion sensitive probe but almost insensitive to its orientation with the total magnetic field. Therefore it can be used to measure the plasma potential inside fusion devices, especially in regions with complex magnetic field topology. Experimental results are presented and compared with Ball-Pen probe measurements taken under identical conditions. We have observed that the floating potential of the Bunker probe is indeed little affected by its orientation with the magnetic field for angles ranging from 90° to 30°, in contrast to the Ball-Pen probe whose floating potential decreases towards that of a Langmuir probe if not properly aligned with the magnetic field.

  19. Bunker probe: A plasma potential probe almost insensitive to its orientation with the magnetic field

    International Nuclear Information System (INIS)

    Costea, S.; Schneider, B. S.; Schrittwieser, R.; Ionita, C.; Fonda, B.; Kovačič, J.; Gyergyek, T.

    2016-01-01

    Due to their ability to suppress a large part of the electron current and thus measuring directly the plasma potential, ion sensitive probes have begun to be widely tested and used in fusion devices. For these probes to work, almost perfect alignment with the total magnetic field is necessary. This condition cannot always be fulfilled due to the curvature of magnetic fields, complex magnetic structure, or magnetic field reconnection. In this perspective, we have developed a plasma potential probe (named Bunker probe) based on the principle of the ion sensitive probe but almost insensitive to its orientation with the total magnetic field. Therefore it can be used to measure the plasma potential inside fusion devices, especially in regions with complex magnetic field topology. Experimental results are presented and compared with Ball-Pen probe measurements taken under identical conditions. We have observed that the floating potential of the Bunker probe is indeed little affected by its orientation with the magnetic field for angles ranging from 90° to 30°, in contrast to the Ball-Pen probe whose floating potential decreases towards that of a Langmuir probe if not properly aligned with the magnetic field.

  20. Eddy Current Probe for Surface and Sub-Surface Inspection

    Science.gov (United States)

    Wincheski, Russell A. (Inventor); Simpson, John W. (Inventor)

    2014-01-01

    An eddy current probe includes an excitation coil for coupling to a low-frequency alternating current (AC) source. A magneto-resistive sensor is centrally disposed within and at one end of the excitation coil to thereby define a sensing end of the probe. A tubular flux-focusing lens is disposed between the excitation coil and the magneto-resistive sensor. An excitation wire is spaced apart from the magneto-resistive sensor in a plane that is perpendicular to the sensor's axis of sensitivity and such that, when the sensing end of the eddy current probe is positioned adjacent to the surface of a structure, the excitation wire is disposed between the magneto-resistive sensor and the surface of the structure. The excitation wire is coupled to a high-frequency AC source. The excitation coil and flux-focusing lens can be omitted when only surface inspection is required.

  1. Magnetic Classification of Meteorites and Asteroid Probing

    Science.gov (United States)

    Rochette, P.; Sagnotti, L.; Chevrier, V.; Consolmagno, G.; Denise, M.; Folco, L.; Osete, M.; Pesonen, L.

    intrinsic magnetic field the only way to measure X is to use a lander able to apply a small coil on the surface to mea- sure. Existing pocket susceptometer with a 25 mm radius loop and penetration depth of 30 mm are easily adaptable to such a purpose with a payload of less than 50 g (not counting the mobile arm). Such a petrophysical tool would have the advantage of its penetration depth with respect to all other chemical and mineralogical analysers that obtain essentially surface information prone to bias by space weathering. It should allow to attribute the asteroid to a meteorite class.

  2. Spin polarized auger electron spectroscopy (SPAES): An element specific local magnetization probe of magnetic materials

    Science.gov (United States)

    Anilturk, Onder S.

    Spin Polarized Auger Electron Spectroscopy (SPAES) is found to have application for investigating fundamental properties as well as element specific local magnetization information on magnetic materials. By using the uniqueness of the UTA-SEMPA tool, one can obtain the surface magnetic domain microstructure and also perform SPAES studies by probing a single domain at the surface. In the current study, knowing the probed domain, spin polarization of electrons from super Coster-Kronig MVV Auger emissions on 3%Si-Fe sheets have been investigated. It is observed that on both sides of 180° domains, separated by a domain wall with an out-of-plane component of magnetization, the spin polarized Auger spectra exhibit similar distributions with high polarization structures, which are consistent with the published data. The element specificity of the system is applied to Gd-Co composite system. Details of 4d core hole initiated Auger transitions showed that the 5d states have enhanced spin polarization, confirming the coupling of moments in the composite system via 5d states of Gd. It is also unambiguously observed that Co magnetic moments are indeed aligned antiparallel to the Gd ones via 4f-5d positive exchange and 3d-5d hybridization.

  3. Nanofabrication of magnetic scanned-probe microscope sensors

    CERN Document Server

    Chong, B K

    2001-01-01

    experiments were carried out under ambient conditions. The experiments required no extra preparation to be done to the specimen before imaging and measurements were carried out under ambient conditions. These probes offer the prospect of direct magnetic field measurement, non- invasiveness, very close proximity, possible local manipulation, better control over the tip- specimen interaction distance and topographic imaging. It is hoped that these magnetic microscope probes will be of great interest and general utility for academic and industrial magneticians. This thesis presents the development of novel magnetic sensor combined with Atomic Force Microscope probe (AFM) using conventional semiconductor processing techniques and Electron Beam Lithography (EBL). The fabrication of these magnetic sensors was performed on a common micromachined silicon substrate using a generic batch fabrication technique. Sub-micron Hall bar for Scanning Hall probe Microscopy (SHPM) and electromagnetic force coil magnet for Scanni...

  4. Resonator Sensitivity Optimization in Magnetic Resonance and the Development of a Magic Angle Spinning Probe for the NMR Study of Rare Spin Nuclei on Catalytic Surfaces.

    Science.gov (United States)

    Doty, Francis David

    The sensitivity of an arbitrary resonator for the detection of a magnetic resonance signal is derived from basic energy considerations, and is shown to be dependent on V(,s)/t(,90)P(' 1/2). The radiation damping time constant is shown to be inversely dependent on the rf filling factor. Several resonators are analyzed in detail. The optimum solenoid is shown to have a length of about 1.5 times the diameter. The multilayer solenoid and the capacitively shortened slotted line resonator are shown to have advantages for samples with high dielectric losses. The capacitively shortened slotted line resonator is shown to substantially reduce acoustic ringing problems. Efficient methods are discussed for double and triple tuning these resonators. A slotted cylindrical resonator is described which gives higher sensitivity and faster response time than conventional cavities for very small samples at X-band ESR frequencies. Double tuned circuits using lumped elements are shown to be generally more efficient than those using transmission lines in generating rf fields. The optimum inductance ratio of the two coils in a ('13)C, ('1)H CP experiment is about 3. The high speed cylindrical sample spinner is analyzed in terms of compressible fluid dynamics, resonant modes, and structural analysis to arrive at optimum air bearing and spinner design recommendations. The optimum radial clearance is shown to depend on the 1/3 power of the rotor diameter. The required air bearing hole diameter has a square root dependence on the rotor diameter. Air pockets are shown to increase the resonant frequencies. Relevant data for a number of high strength insulators including hard ceramics are tabulated, and limiting speeds are calculated. CP MAS experiments on a 5% monolayer of n-butylamine absorbed on (gamma)-alumina reveal six lines. By comparison with the liquid phase spectrum it was determined that at least two types of chemically different surface species were present and that surface

  5. Probes for anionic cell surface detection

    Science.gov (United States)

    Smith, Bradley D.

    2013-03-05

    Embodiments of the present invention are generally directed to compositions comprising a class of molecular probes for detecting the presence of anionic cell surfaces. Embodiments include compositions that are enriched for these compositions and preparations, particularly preparations suitable for use as laboratory/clinical reagents and diagnostic indicators, either alone or as part of a kit. An embodiment of the invention provides for a highly selective agent useful in the discernment and identification of dead or dying cells, such as apoptotic cells, in a relatively calcium-free environment. An embodiment of the invention provides a selective agent for the identification of bacteria in a mixed population of bacterial cells and nonbacterial cells.

  6. Polarized SANS for probing magnetic nanostructures

    Science.gov (United States)

    Wiedenmann, Albrecht

    2005-02-01

    Cross-sections for small angle neutron scattering, using non-polarised and polarised neutrons, with and without polarisation analysis, are derived for single-domain ferromagnetic particles when inter-particle correlations are taken into account. The potential for magnetic contrast variation is demonstrated by investigations of poly disperse magnetic colloids. Size distributions, compositions and magnetic moments of magnetic composites and magnetic aggregates were determined precisely independently from that of non-magnetic micelles and free surfactants of similar sizes. Nuclear and magnetic inter-particle correlations have been extracted from the scattering signals by using polarisation analysis via a 3He filter cell.

  7. Polarized SANS for probing magnetic nanostructures

    International Nuclear Information System (INIS)

    Wiedenmann, Albrecht

    2005-01-01

    Cross-sections for small angle neutron scattering, using non-polarised and polarised neutrons, with and without polarisation analysis, are derived for single-domain ferromagnetic particles when inter-particle correlations are taken into account. The potential for magnetic contrast variation is demonstrated by investigations of poly disperse magnetic colloids. Size distributions, compositions and magnetic moments of magnetic composites and magnetic aggregates were determined precisely independently from that of non-magnetic micelles and free surfactants of similar sizes. Nuclear and magnetic inter-particle correlations have been extracted from the scattering signals by using polarisation analysis via a 3 He filter cell

  8. Probing Magnetic Fields with Square Kilometre Array and its ...

    Indian Academy of Sciences (India)

    of-sight (along the galactic plane). Probing magnetic fields by FD alone will fail to give complete information about these systematic fields. In radio, these fields are probed by synchrotron emission. Despite the limitation due to assumption of ...

  9. Probing Anisotropic Surface Properties and Surface Forces of Fluorite Crystals.

    Science.gov (United States)

    Gao, Zhiyong; Xie, Lei; Cui, Xin; Hu, Yuehua; Sun, Wei; Zeng, Hongbo

    2018-02-20

    Fluorite is the most important mineral source for producing fluorine-based chemicals and materials in a wide range of engineering and technological applications. In this work, atomic force microscopy was employed, for the first time, to probe the surface interactions and adhesion energy of model oleic acid (a commonly used surface modification organics for fluorite) molecules on fluorite surfaces with different orientations in both air and aqueous solutions at different pH conditions. Fitted with the Derjaguin-Landau-Verwey-Overbeek theory, the force results during surface approaching demonstrate the anisotropy in the surface charge of different orientations, with the {111} surface exhibiting a higher magnitude of surface charge, which could be attributed to the difference in the atomic composition. The adhesion measured during surface retraction shows that model oleic acid molecules have a stronger adhesion with the {100} surface than with the {111} surface in both air and aqueous solutions. The anisotropic adhesion energy was analyzed in relation to the surface atom (especially calcium) activity, which was supported by the surface free energy results calculated based on a three-probe-liquid method. Each calcium atom on the {100} surface with four dangling bonds is more active than the calcium atom on the {111} surface with only one dangling bond, supported by a larger value of the Lewis acid component for the {100} surface. The model oleic acid molecules present in the ionic form at pH 9 exhibit a higher adhesion energy with fluorite surfaces as compared to their molecular form at pH 6, which was related to the surface activity of different forms. The adhesion energy measured in solution is much lower than that in air, indicating that the solvent exerts an important influence on the interactions of organic molecules with mineral surfaces. The results provide useful information on the fundamental understanding of surface interactions and adhesion energy of organic

  10. Molecular Tension Probes for Imaging Forces at the Cell Surface.

    Science.gov (United States)

    Liu, Yang; Galior, Kornelia; Ma, Victor Pui-Yan; Salaita, Khalid

    2017-12-19

    Mechanical forces are essential for a variety of biological processes ranging from transcription and translation to cell adhesion, migration, and differentiation. Through the activation of mechanosensitive signaling pathways, cells sense and respond to physical stimuli from the surrounding environment, a process widely known as mechanotransduction. At the cell membrane, many signaling receptors, such as integrins, cadherins and T- or B-cell receptors, bind to their ligands on the surface of adjacent cells or the extracellular matrix (ECM) to mediate mechanotransduction. Upon ligation, these receptor-ligand bonds transmit piconewton (pN) mechanical forces that are generated, in part, by the cytoskeleton. Importantly, these forces expose cryptic sites within mechanosensitive proteins and modulate the binding kinetics (on/off rate) of receptor-ligand complexes to further fine-tune mechanotransduction and the corresponding cell behavior. Over the past three decades, two categories of methods have been developed to measure cell receptor forces. The first class is traction force microscopy (TFM) and micropost array detectors (mPADs). In these methods, cells are cultured on elastic polymers or microstructures that deform under mechanical forces. The second category of techniques is single molecule force spectroscopy (SMFS) including atomic force microscopy (AFM), optical or magnetic tweezers, and biomembrane force probe (BFP). In SMFS, the experimenter applies external forces to probe the mechanics of individual cells or single receptor-ligand complexes, serially, one bond at a time. Although these techniques are powerful, the limited throughput of SMFS and the nN force sensitivity of TFM have hindered further elucidation of the molecular mechanisms of mechanotransduction. In this Account, we introduce the recent advent of molecular tension fluorescence microscopy (MTFM) as an emerging tool for molecular imaging of receptor mechanics in living cells. MTFM probes are

  11. The magnetic-distortion probe: velocimetry in conducting fluids.

    Science.gov (United States)

    Miralles, Sophie; Verhille, Gautier; Plihon, Nicolas; Pinton, Jean-François

    2011-09-01

    A new type of velocimeter, capable of local velocity measurements in conducting fluids, is introduced. The principle of the "magnetic-distortion probe" is based on the measurement of the induced magnetic field by the flow of a conducting fluid in the vicinity of a localized magnetic field. The new velocimeter has no moving parts, and can be enclosed in a sealed cap, easing the implementation in harsh environments, such as liquid metals. The proposed method allows one to probe both the continuous part and fluctuations of the velocity, the temporal and spatial resolution being linked to the actual geometric configuration of the probe. A prototype probe has been tested in a gallinstan pipe flow and in a fully turbulent flow of liquid gallium generated by the counter rotation of two coaxial impellers in a cylinder. The signals have been compared to a reference potential probe and show very good agreement both for time-averaged velocities and turbulent fluctuations. The prototype is shown to detect motion from a few cm s(-1) to a few m s(-1). Moreover, the use of the magnetic-distortion probe with large-scale applied magnetic field is discussed. © 2011 American Institute of Physics

  12. A modified Katsumata probe - ion sensitive probe for measurement in non-magnetized plasmas

    Czech Academy of Sciences Publication Activity Database

    Čada, Martin; Hubička, Zdeněk; Adámek, Petr; Olejníček, Jiří; Kment, Štěpán; Adámek, Jiří; Stöckel, Jan

    2015-01-01

    Roč. 86, č. 7 (2015), "073510-1"-"073510-7" ISSN 0034-6748 R&D Projects: GA MŠk LH12043 Institutional support: RVO:68378271 ; RVO:61389021 Keywords : Katsumata probe * non-magnetized plasma * magnetron * ion temperature * non-magnetized plasmas Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.336, year: 2015

  13. Waveguide volume probe for magnetic resonance imaging and spectroscopy

    DEFF Research Database (Denmark)

    2015-01-01

    The present disclosure relates to a probe for use within the field of nuclear magnetic resonance, such as magnetic resonance imaging (MRI), and magnetic resonance spectroscopy (MRS)). One embodiment relates to an RF probe for magnetic resonance imaging and/or spectroscopy comprising a conductive...... non-magnetic hollow waveguide having an internal volume and at least one open end, one or more capacitors and at least a first conductive non-magnetic wire, wherein said first conductive wire connects at least one of said one or more capacitors to opposite walls of one open end of the waveguide...... and wherein said first conductive wire and said one or more capacitors are located outside of said internal volume, wherein the internal volume of the hollow waveguide defines an imaging volume or sample volume....

  14. Eddy current probe development based on a magnetic sensor array

    International Nuclear Information System (INIS)

    Vacher, F.

    2007-06-01

    This research deals with in the study of the use of innovating magnetic sensors in eddy current non destructive inspection. The author reports an analysis survey of magnetic sensor performances. This survey enables the selection of magnetic sensor technologies used in non destructive inspection. He presents the state-of-the-art of eddy current probes exploiting the qualities of innovating magnetic sensors, and describes the methods enabling the use of these magnetic sensors in non destructive testing. Two main applications of innovating magnetic sensors are identified: the detection of very small defects by means of magneto-resistive sensors, and the detection of deep defects by means of giant magneto-impedances. Based on the use of modelling, optimization, signal processing tools, probes are manufactured for these both applications

  15. Probing electric and magnetic vacuum fluctuations with quantum dots

    OpenAIRE

    Tighineanu, Petru; Andersen, Mads Lykke; Sørensen, Anders Søndberg; Stobbe, Søren; Lodahl, Peter

    2014-01-01

    The electromagnetic-vacuum-field fluctuations are intimately linked to the process of spontaneous emission of light. Atomic emitters cannot probe electric- and magnetic-field fluctuations simultaneously because electric and magnetic transitions correspond to different selection rules. In this paper we show that semiconductor quantum dots are fundamentally different and are capable of mediating electric-dipole, magnetic-dipole, and electric-quadrupole transitions on a single electronic resonan...

  16. Probing Magnetic Fields of Early Galaxies

    Science.gov (United States)

    Kohler, Susanna

    2017-06-01

    How do magnetic fields form and evolve in early galaxies? A new study has provided some clever observations to help us answer this question.The Puzzle of Growing FieldsDynamo theory is the primary model describing how magnetic fields develop in galaxies. In this picture, magnetic fields start out as weak seed fields that are small and unordered. These fields then become ordered and amplified by large-scale rotation and turbulence in galaxy disks and halos, eventually leading to the magnetic fields we observe in galaxies today.Schematic showinghow to indirectly measure protogalactic magnetic fields. The measured polarization of a background quasar is altered by the fields in a foreground protogalaxy. Click for a closer look! [Farnes et al. 2017/Adolf Schaller/STSCI/NRAO/AUI/NSF]To test this model, we need observations of the magnetic fields in young protogalaxies. Unfortunately, we dont have the sensitivity to be able to measure these fields directly but a team of scientists led by Jamie Farnes (Radboud University in the Netherlands) have come up with a creative alternative.The key is to find early protogalaxies that absorb the light of more distant background objects. If a protogalaxy lies between us and a distant quasar, then magnetic fields of the protogalaxy if present will affect the polarization measurements of the background quasar.Observing Galactic Building BlocksTop: Redshift distribution for the background quasars in the authors sample. Bottom: Redshift distribution for the foreground protogalaxies the authors are exploring. [Farnes et al. 2017]Farnes and collaborators examined two types of foreground protogalaxies: Damped Lyman-Alpha Absorbers (DLAs) and Lyman Limit Systems (LLSs). They obtained polarimetric data for a sample of 114 distant quasars with nothing in the foreground (the control sample), 19 quasars with DLAs in the foreground, and 27 quasars with LLSs in the foreground. They then used statistical analysis techniques to draw conclusions about

  17. Surface magnetic structures in amorphous ferromagnetic microwires

    International Nuclear Information System (INIS)

    Usov, N.A.; Serebryakova, O.N.; Gudoshnikov, S.A.; Tarasov, V.P.

    2017-01-01

    The spatial period of magnetization perturbations that occur near the surface of magnetic nanotube or nanowire under the influence of surface magnetic anisotropy is determined by means of numerical simulation as a function of the sample geometry and material parameters. The surface magnetization distribution obtained is then used to estimate the period of the surface magnetic texture in amorphous microwire of several micrometers in diameter by means of appropriate variational procedure. The period of the surface magnetic texture in amorphous microwire is found to be significantly smaller than the wire diameter. - Highlights: • Magnetic structure may arise near the magnetic nanotube surface under the influence of surface magnetic anisotropy. • The period of the surface magnetization pattern is calculated as a function of the sample geometry. • Similar magnetic structure may exist in amorphous microwire of several micrometers in diameter. • The period of the surface magnetic structure in amorphous wire is found to be significantly smaller than the wire diameter.

  18. Surface magnetic structures in amorphous ferromagnetic microwires

    Energy Technology Data Exchange (ETDEWEB)

    Usov, N.A., E-mail: usov@obninsk.ru [National University of Science and Technology «MISIS», 119049 Moscow (Russian Federation); Pushkov Institute of Terrestrial Magnetism, Ionosphere and Radio Wave Propagation, Russian Academy of Sciences, IZMIRAN, 108840 Troitsk, Moscow (Russian Federation); Serebryakova, O.N.; Gudoshnikov, S.A. [National University of Science and Technology «MISIS», 119049 Moscow (Russian Federation); Pushkov Institute of Terrestrial Magnetism, Ionosphere and Radio Wave Propagation, Russian Academy of Sciences, IZMIRAN, 108840 Troitsk, Moscow (Russian Federation); Tarasov, V.P. [National University of Science and Technology «MISIS», 119049 Moscow (Russian Federation)

    2017-05-01

    The spatial period of magnetization perturbations that occur near the surface of magnetic nanotube or nanowire under the influence of surface magnetic anisotropy is determined by means of numerical simulation as a function of the sample geometry and material parameters. The surface magnetization distribution obtained is then used to estimate the period of the surface magnetic texture in amorphous microwire of several micrometers in diameter by means of appropriate variational procedure. The period of the surface magnetic texture in amorphous microwire is found to be significantly smaller than the wire diameter. - Highlights: • Magnetic structure may arise near the magnetic nanotube surface under the influence of surface magnetic anisotropy. • The period of the surface magnetization pattern is calculated as a function of the sample geometry. • Similar magnetic structure may exist in amorphous microwire of several micrometers in diameter. • The period of the surface magnetic structure in amorphous wire is found to be significantly smaller than the wire diameter.

  19. Analysis of Scanned Probe Images for Magnetic Focusing in Graphene

    Science.gov (United States)

    Bhandari, Sagar; Lee, Gil-Ho; Kim, Philip; Westervelt, Robert M.

    2017-07-01

    We have used cooled scanning probe microscopy (SPM) to study electron motion in nanoscale devices. The charged tip of the microscope was raster-scanned at constant height above the surface as the conductance of the device was measured. The image charge scatters electrons away, changing the path of electrons through the sample. Using this technique, we imaged cyclotron orbits that flow between two narrow contacts in the magnetic focusing regime for ballistic hBN-graphene-hBN devices. We present herein an analysis of our magnetic focusing imaging results based on the effects of the tip-created charge density dip on the motion of ballistic electrons. The density dip locally reduces the Fermi energy, creating a force that pushes electrons away from the tip. When the tip is above the cyclotron orbit, electrons are deflected away from the receiving contact, creating an image by reducing the transmission between contacts. The data and our analysis suggest that the graphene edge is rather rough, and electrons scattering off the edge bounce in random directions. However, when the tip is close to the edge, it can enhance transmission by bouncing electrons away from the edge, toward the receiving contact. Our results demonstrate that cooled SPM is a promising tool to investigate the motion of electrons in ballistic graphene devices.

  20. A read and write element for magnetic probe recording

    International Nuclear Information System (INIS)

    Craus, C B; Onoue, T; Ramstoeck, K; Geerts, W G M A; Siekman, M H; Abelmann, L; Lodder, J C

    2005-01-01

    We present our results on the development of magnetic sensors for application in magnetic probe recording. Successful writing experiments on a magnetic medium with perpendicular anisotropy show that magnetic domains of 130 nm can be reversed in a heat-assisted process. For reading purposes we propose a magnetoresistive sensor. The optimization of the shape of the sensor was performed using micromagnetic simulations with the requirement that the sensor has to be capable of both read and write operations. At this stage, the experimental realization of the sensor was carried out at a wafer-base level. The fabrication technique consists of a combination of optical lithography and focused ion beam etching

  1. Performance of field measuring probes for SSC magnets

    International Nuclear Information System (INIS)

    Thomas, R.; Ganetis, G.; Herrera, J.; Hogue, R.; Jain, A.; Louie, W.; Marone, A.; Wanderer, P.

    1994-01-01

    Several years of experience have been acquired on the operation of probes (open-quotes molesclose quotes) constructed for the measurement of the multipole components of the magnetic fields of SSC magnets. The field is measured by rotating coils contained in a 2.4-m long tube that is pulled through the aperture of the magnet by an external device - the transporter. In addition to the measuring coils, the tube contains motors for rotating the coil and a system for sensing local vertical using gravity sensors to provide an absolute reference for the field measurements. The authors describe the steps that must be taken in order to ensure accurate, repeatable measurements; the design changes that have been motivated by difficulties encountered (noise, vibration, variations in temperature); and other performance issues. The mechanical interface between the probe and the beam tube of the magnet is also described

  2. Soft-landing deposition of radioactive probe atoms on surfaces

    NARCIS (Netherlands)

    Laurens, C.R; Rosu, M.F; Pleiter, F; Niesen, L

    1999-01-01

    We present a method to deposit a wide range of radioactive probe atoms on surfaces, without introducing lattice damage or contaminating the surface with other elements or isotopes. In this method, the probe atoms are mass-separated using an isotope separa-tor, decelerated to 5 eV, and directly

  3. Moment switching in nanotube magnetic force probes

    NARCIS (Netherlands)

    Kirtley, J.R.; Deng, Z.; Luan, L.; Yenilmez, E.; Dai, H.; Moler, K.A.

    2007-01-01

    Magnetic images of high density vertically recorded media using metal-coated carbon nanotube tips exhibit a doubling of the spatial frequency under some conditions (Deng et al 2004 Appl. Phys. Lett. 85 6263). Here we demonstrate that this spatial frequency doubling is due to the switching of the

  4. Distinguishing magnetic and electrostatic interactions by a Kelvin probe force microscopy-magnetic force microscopy combination.

    Science.gov (United States)

    Jaafar, Miriam; Iglesias-Freire, Oscar; Serrano-Ramón, Luis; Ibarra, Manuel Ricardo; de Teresa, Jose Maria; Asenjo, Agustina

    2011-01-01

    The most outstanding feature of scanning force microscopy (SFM) is its capability to detect various different short and long range interactions. In particular, magnetic force microscopy (MFM) is used to characterize the domain configuration in ferromagnetic materials such as thin films grown by physical techniques or ferromagnetic nanostructures. It is a usual procedure to separate the topography and the magnetic signal by scanning at a lift distance of 25-50 nm such that the long range tip-sample interactions dominate. Nowadays, MFM is becoming a valuable technique to detect weak magnetic fields arising from low dimensional complex systems such as organic nanomagnets, superparamagnetic nanoparticles, carbon-based materials, etc. In all these cases, the magnetic nanocomponents and the substrate supporting them present quite different electronic behavior, i.e., they exhibit large surface potential differences causing heterogeneous electrostatic interaction between the tip and the sample that could be interpreted as a magnetic interaction. To distinguish clearly the origin of the tip-sample forces we propose to use a combination of Kelvin probe force microscopy (KPFM) and MFM. The KPFM technique allows us to compensate in real time the electrostatic forces between the tip and the sample by minimizing the electrostatic contribution to the frequency shift signal. This is a great challenge in samples with low magnetic moment. In this work we studied an array of Co nanostructures that exhibit high electrostatic interaction with the MFM tip. Thanks to the use of the KPFM/MFM system we were able to separate the electric and magnetic interactions between the tip and the sample.

  5. Distinguishing magnetic and electrostatic interactions by a Kelvin probe force microscopy–magnetic force microscopy combination

    Directory of Open Access Journals (Sweden)

    Miriam Jaafar

    2011-09-01

    Full Text Available The most outstanding feature of scanning force microscopy (SFM is its capability to detect various different short and long range interactions. In particular, magnetic force microscopy (MFM is used to characterize the domain configuration in ferromagnetic materials such as thin films grown by physical techniques or ferromagnetic nanostructures. It is a usual procedure to separate the topography and the magnetic signal by scanning at a lift distance of 25–50 nm such that the long range tip–sample interactions dominate. Nowadays, MFM is becoming a valuable technique to detect weak magnetic fields arising from low dimensional complex systems such as organic nanomagnets, superparamagnetic nanoparticles, carbon-based materials, etc. In all these cases, the magnetic nanocomponents and the substrate supporting them present quite different electronic behavior, i.e., they exhibit large surface potential differences causing heterogeneous electrostatic interaction between the tip and the sample that could be interpreted as a magnetic interaction. To distinguish clearly the origin of the tip–sample forces we propose to use a combination of Kelvin probe force microscopy (KPFM and MFM. The KPFM technique allows us to compensate in real time the electrostatic forces between the tip and the sample by minimizing the electrostatic contribution to the frequency shift signal. This is a great challenge in samples with low magnetic moment. In this work we studied an array of Co nanostructures that exhibit high electrostatic interaction with the MFM tip. Thanks to the use of the KPFM/MFM system we were able to separate the electric and magnetic interactions between the tip and the sample.

  6. Probing lateral magnetic nanostructures by polarized GISANS

    International Nuclear Information System (INIS)

    Kentzinger, E.; Frielinghaus, H.; Ruecker, U.; Ioffe, A.; Richter, D.; Brueckel, Th.

    2007-01-01

    While structural and magnetic lateral correlations in thin film materials can be investigated at the μm length scale by neutron off-specular scattering (OSS) with polarization analysis, they can also be investigated at the nm length scale by grazing incidence small-angle scattering of polarized neutrons (polarized GISANS). We exemplify this issue showing a combined OSS and GISANS study of the lateral correlations in a remanent polarizing supermirror

  7. Probing lateral magnetic nanostructures by polarized GISANS

    Science.gov (United States)

    Kentzinger, E.; Frielinghaus, H.; Rücker, U.; Ioffe, A.; Richter, D.; Brückel, Th.

    2007-07-01

    While structural and magnetic lateral correlations in thin film materials can be investigated at the μm length scale by neutron off-specular scattering (OSS) with polarization analysis, they can also be investigated at the nm length scale by grazing incidence small-angle scattering of polarized neutrons (polarized GISANS). We exemplify this issue showing a combined OSS and GISANS study of the lateral correlations in a remanent polarizing supermirror.

  8. Magnetic Probe Construction using Thick-film Technology

    International Nuclear Information System (INIS)

    Takahashi, H.; Sakakibara, S.; Kubota, Y.; Yamada, H.

    2001-01-01

    Thick-film technology has been successfully adapted for the design and fabrication of magnetic probes of a new type suitable for use in the simultaneous ultra-high vacuum and high-temperature environment of a nuclear fusion device. The maximum usable temperature is expected to be around 900 degrees C. This new probe has a specific sensitivity (coupling area per unit volume) an order of magnitude higher than a conventional coil. The new probe in one implementation is capable of simultaneously measuring magnetic field in three orthogonal directions about a single spatial point and in two frequency ranges. Low-frequency coils have a measured coupling area of 296-323 cm squared and a frequency response of about 300 kHz. High-frequency coils have a design coupling area of 12-15 cm squared

  9. The role of probe oxide in local surface conductivity measurements

    Science.gov (United States)

    Barnett, C. J.; Kryvchenkova, O.; Wilson, L. S. J.; Maffeis, T. G. G.; Kalna, K.; Cobley, R. J.

    2015-05-01

    Local probe methods can be used to measure nanoscale surface conductivity, but some techniques including nanoscale four point probe rely on at least two of the probes forming the same low resistivity non-rectifying contact to the sample. Here, the role of probe shank oxide has been examined by carrying out contact and non-contact I V measurements on GaAs when the probe oxide has been controllably reduced, both experimentally and in simulation. In contact, the barrier height is pinned but the barrier shape changes with probe shank oxide dimensions. In non-contact measurements, the oxide modifies the electrostatic interaction inducing a quantum dot that alters the tunneling behavior. For both, the contact resistance change is dependent on polarity, which violates the assumption required for four point probe to remove probe contact resistance from the measured conductivity. This has implications for all nanoscale surface probe measurements and macroscopic four point probe, both in air and vacuum, where the role of probe oxide contamination is not well understood.

  10. Prospects for neutron probed magnetic resonance imaging

    International Nuclear Information System (INIS)

    Granroth, Garrett E.

    2009-01-01

    The information gained from magnetic resonance imaging has provided useful insight into many insulators. Extending this technique to conductors requires an alternative means of spin manipulation besides electromagnetic radiation. A method to use neutron measurement of the Zeeman splitting to measure the relaxation time is described. The Zeeman splitting is observed by a neutron spectrometer as an incoherent signal with an energy transfer equal to the Zeeman energy. This energy scale is so small that fields in excess of 15 T are required to sufficiently separate this line from other incoherent processes. Once the Zeeman splitting is observed, a perturbation of the system is required to enable measurement of the nuclear spin relaxation time; the physical quantity measured in a Nuclear Magnetic Resonance experiment. The proposed perturbation is a pulsed field of 10 T. The relaxation of the Zeeman splitting back to the 15 T condition is then recorded as a function of time. The resultant data is the aforementioned measure of the relaxation time. With the ability to measure the relaxation times the image map can be created by rastering the sample with respect to the beam.

  11. Local magnetism in palladium bionanomaterials probed by muon spectroscopy.

    Science.gov (United States)

    Creamer, Neil J; Mikheenko, Iryna P; Johnson, Clive; Cottrell, Stephen P; Macaskie, Lynne E

    2011-05-01

    Palladium bionanomaterial was manufactured using the sulfate-reducing bacterium, Desulfovibrio desulfuricansm, to reduce soluble Pd(II) ions to cell-bound Pd(0) in the presence of hydrogen. The biomaterial was examined using a Superconducting Quantum Interference Device (SQUID) to measure bulk magnetisation and by Muon Spin Rotation Spectroscopy (µSR) which is uniquely able to probe the local magnetic environment inside the sample. Results showed behaviour attributable to interaction of muons both with palladium electrons and the nuclei of hydrogen trapped in the particles during manufacture. Electronic magnetism, also suggested by SQUID, is not characteristic of bulk palladium and is consistent with the presence of nanoparticles previously seen in electron micrographs. We show the first use of μSR as a tool to probe the internal magnetic environment of a biologically-derived nanocatalyst material. © Springer Science+Business Media B.V. 2011

  12. Probing Nanoscale Electronic and Magnetic Interaction with Scanning Tunneling Spectroscopy

    DEFF Research Database (Denmark)

    Bork, Jakob

    This thesis is concerned with fundamental research into electronic and magnetic interaction on the nanoscale. From small metallic and magnetic islands and layers to single atoms. The research revolves around magnetic interaction probed through the spectroscopic capabilities of the scanning....... This is related to research in correlated electron materials such as studies of phase transitions in heavy fermion compounds and magnetic interaction in spintronic research. The capping of cobalt islands on Cu(111) with silver is investigated with STM and photoemission spectroscopy. It is shown that at low...... coverage the silver preferably nucleates on top of the bilayer high cobalt islands compared to directly on the Cu(111) substrate. Furthermore, the silver forms a combination of a reconstruction and a Moire pattern which is investigated with low-energy electron diraction and spectroscopic STM mapping at 6...

  13. Surface chemical reactions probed with scanning force microscopy

    NARCIS (Netherlands)

    Werts, M.P L; van der Vegte, E.W.; Hadziioannou, G

    1997-01-01

    In this letter we report the study of surface chemical reactions with scanning force microscopy (SFM) with chemical specificity. Using chemically modified SFM probes, we can determine the local surface reaction conversion during a chemical surface modification. The adhesion forces between a

  14. Novel magnetic heating probe for multimodal cancer treatment.

    Science.gov (United States)

    Kan-Dapaah, Kwabena; Rahbar, Nima; Soboyejo, Wole

    2015-05-01

    Multifunctional materials consisting of polymers and magnetic nanoparticles (MNPs) are highly sought after in the field of biomedical engineering. These materials offer new opportunities for the development of novel cancer treatment modalities that can increase the efficacy of cancer therapy. In this paper, a novel probe for multimodal cancer treatment is proposed and analyzed. The probe is essentially a cannula with two main parts: a distal heat generating tip made of a magnetic nanocomposite and a proximal insulated shaft. A description of the concept and functional operations of the probe is presented. In an effort to assess its feasibility, the authors evaluated the ability of probe tip (made of PMMA-Fe3O4 nanocomposite) to generate heat in biological tissue using alternating magnetic field (AMF) parameters (field strength and frequency) that are acceptable for human use. Heat generation by MNPs was determined using the linear response theory. The effects of Fe3O4 volume fraction on heat generation as well as treatment time on the thermal dose were studied. The finite element method model was tested for its validity using an analytical model. Lesions were revealed to have an ellipsoidal shape and their sizes were affected by treatment time. However, their shapes remained unchanged. The comparison with the analytical model showed reasonably a good agreement to within 2%. Furthermore, the authors' numerical predictions also showed reasonable agreement with the experimental results previously reported in the literature. The authors' predictions demonstrate the feasibility of their novel probe to achieve reasonable lesion sizes, during hyperthermic or ablative heating using AMF parameters (field strength and frequency) that are acceptable for human use.

  15. Topological mass of magnetic Skyrmions probed by ultrafast dynamic imaging

    International Nuclear Information System (INIS)

    Buettner, Felix

    2013-01-01

    In this thesis, we investigate the GHz dynamics of skyrmionic spin structures by means of pump-probe dynamic imaging to determine the equation of motion that governs the behavior of these technologically relevant spin structures. To achieve this goal, we first designed and optimized a perpendicular magnetic anisotropy CoB/Pt multilayer material for low magnetic pinning, as required for ultrafast pump-probe imaging experiments. Second, we developed an integrated sample design for X-ray holography capable of tracking relative magnetic positional changes down to 3 nm spatial resolution. These advances enabled us to image the trajectory of a single magnetic Skyrmion. We find that the motion is comprised of two gyrotropic modes, one clockwise and one counterclockwise. The existence of two modes shows that Skyrmions are massive quasiparticles. From their derived frequencies we find an inertial mass for the Skyrmion which is a factor of five larger than expected based on existing models for inertia in magnetism. Our results demonstrate that the mass of Skyrmions is based on a novel mechanism emerging from their confined nature, which is a direct consequence of their topology.

  16. Three axis vector magnet set-up for cryogenic scanning probe microscopy

    International Nuclear Information System (INIS)

    Galvis, J. A.; Herrera, E.; Buendía, A.; Guillamón, I.; Vieira, S.; Suderow, H.; Azpeitia, J.; Luccas, R. F.; Munuera, C.; García-Hernandez, M.

    2015-01-01

    We describe a three axis vector magnet system for cryogenic scanning probe microscopy measurements. We discuss the magnet support system and the power supply, consisting of a compact three way 100 A current source. We obtain tilted magnetic fields in all directions with maximum value of 5T along z-axis and of 1.2T for XY-plane magnetic fields. We describe a scanning tunneling microscopy-spectroscopy (STM-STS) set-up, operating in a dilution refrigerator, which includes a new high voltage ultralow noise piezodrive electronics and discuss the noise level due to vibrations. STM images and STS maps show atomic resolution and the tilted vortex lattice at 150 mK in the superconductor β-Bi 2 Pd. We observe a strongly elongated hexagonal lattice, which corresponds to the projection of the tilted hexagonal vortex lattice on the surface. We also discuss Magnetic Force Microscopy images in a variable temperature insert

  17. Three axis vector magnet set-up for cryogenic scanning probe microscopy

    Science.gov (United States)

    Galvis, J. A.; Herrera, E.; Guillamón, I.; Azpeitia, J.; Luccas, R. F.; Munuera, C.; Cuenca, M.; Higuera, J. A.; Díaz, N.; Pazos, M.; García-Hernandez, M.; Buendía, A.; Vieira, S.; Suderow, H.

    2015-01-01

    We describe a three axis vector magnet system for cryogenic scanning probe microscopy measurements. We discuss the magnet support system and the power supply, consisting of a compact three way 100 A current source. We obtain tilted magnetic fields in all directions with maximum value of 5T along z-axis and of 1.2T for XY-plane magnetic fields. We describe a scanning tunneling microscopy-spectroscopy (STM-STS) set-up, operating in a dilution refrigerator, which includes a new high voltage ultralow noise piezodrive electronics and discuss the noise level due to vibrations. STM images and STS maps show atomic resolution and the tilted vortex lattice at 150 mK in the superconductor β-Bi2Pd. We observe a strongly elongated hexagonal lattice, which corresponds to the projection of the tilted hexagonal vortex lattice on the surface. We also discuss Magnetic Force Microscopy images in a variable temperature insert.

  18. Surface magnetism of Fe(001)

    International Nuclear Information System (INIS)

    Ohnishi, S.; Freeman, A.J.; Weinert, M.

    1983-01-01

    Results of all-electron self-consistent semirelativistic full-potential linearized augmented-plane-wave local-density and local-spin-density studies are reported for a seven-layer Fe(001) thin film. The calculated work function for the ferromagnetic state is found to be in excellent agreement with experiment, whereas that calculated for the paramagnetic state is significantly worse (namely, 0.5 eV too large), indicating the importance of spin polarization on this electrostatic property. For both states, partial densities of states (projected by layer and by orbital angular momentum), surface states, and charge (and spin) densities are presented and their differences employed to discuss the origin of surface magnetism. No Friedel oscillation is found in the layer-by-layer charge density. The surface-layer magnetic moment is found to have been increased by 0.73μ/sub B/ from the center layer to 2.98μ/sub B//atom; a very small Friedel oscillation is obtained for the spin density, which indicates possible size effects in this seven-layer film. Layer-by-layer Fermi contact hyperfine fields are presented: While the core-polarization contributions are proportional to the magnetic moment, the conduction-electron contribution shows a pronounced Friedel oscillation in the central layer and, significantly, a change of sign and increase in the magnitude for the surface-layer contribution. The hyperfine field at the nucleus of the center-layer atoms is found to be in excellent agreement with experiment

  19. MFM probe control of magnetic vortex chirality in elliptical Co nanoparticles

    International Nuclear Information System (INIS)

    Mironov, V.L.; Gribkov, B.A.; Fraerman, A.A.; Gusev, S.A.; Vdovichev, S.N.; Karetnikova, I.R.; Nefedov, I.M.; Shereshevsky, I.A.

    2007-01-01

    Magnetic force microscopy (MFM) methods were applied to investigate the peculiarities of magnetization distribution in elliptical 400x600x27 nm Co particles. Reversible transitions between the uniform and vortex states under inhomogeneous magnetic field of MFM probe were observed. Possibility to control the chirality of a magnetic vortex in these particles by MFM probe manipulation was shown

  20. Atomic probes of surface structure and dynamics

    International Nuclear Information System (INIS)

    Heller, E.J.; Jonsson, H.

    1992-01-01

    Progress for the period Sept. 15, 1992 to Sept. 14, 1993 is discussed. Semiclassical methods that will allow much faster and more accurate three-dimensional atom--surface scattering calculations, both elastic and inelastic, are being developed. The scattering of He atoms from buckyballs is being investigated as a test problem. Somewhat more detail is given on studies of He atom scattering from defective Pt surfaces. Molecular dynamics simulations of He + and Ar + ion sputtering of Pt surfaces are also being done. He atom scattering from Xe overlayers on metal surfaces and the thermalized dissociation of H 2 on Cu(110) are being studied. (R.W.R.) 64 refs

  1. Magnetic activity at Mars - Mars Surface Magnetic Observatory

    DEFF Research Database (Denmark)

    Vennerstrøm, Susanne; Menvielle, M.; Merayo, José M.G.

    2012-01-01

    We use the extensive database of magnetic observations from the Mars Global Surveyor to investigate magnetic disturbances in the Martian space environment statistically, both close to and far from crustal anomalies. We discuss the results in terms of possible ionospheric and magnetospheric currents...... a magnetic experiment at the martian surface, the Mars Surface Magnetic Observatory (MSMO) including the science objectives, science experiment requirements, instrument and basic operations. We find the experiment to be feasible within the constraints of proposed stationary landing platforms....

  2. Development of flexible array eddy current probes for complex geometries and inspection of magnetic parts using magnetic sensors

    Science.gov (United States)

    Marchand, B.; Decitre, J.-M.; Sergeeva-Chollet, N.; Skarlatos, A.

    2013-01-01

    Eddy Current Technique is a powerful method of inspection of metal parts. When size of flaws decreases, inspection areas become hardly accessible or material is magnetic, traditional winding coil probes are less efficient. Thanks to new CIVA simulation tools, we have designed and optimized advanced EC probes: flexible EC probe based on micro-coil arrays and EC probe with magnetic sensors, including specific electronics.

  3. Surface Plasmon Polaritons Probed with Cold Atoms

    DEFF Research Database (Denmark)

    Kawalec, Tomasz; Sierant, Aleksandra; Panas, Roman

    2017-01-01

    We report on an optical mirror for cold rubidium atoms based on a repulsive dipole potential created by means of a modified recordable digital versatile disc. Using the mirror, we have determined the absolute value of the surface plasmon polariton (SPP) intensity, reaching 90 times the intensity...

  4. Surface modification of YIG by magnet array

    Energy Technology Data Exchange (ETDEWEB)

    Atalay, S., E-mail: satalay@inonu.edu.tr [Inonu University, Science and Art Faculty, Physics Department, 44280 Malatya (Turkey); Kolat, V.S. [Inonu University, Science and Art Faculty, Physics Department, 44280 Malatya (Turkey); Bakır, H.G. [Inonu University, Science and Art Faculty, Astronomy Department, 44280 Malatya (Turkey); Izgi, T.; Kaya, A.O. [Inonu University, Science and Art Faculty, Physics Department, 44280 Malatya (Turkey); Kaya, O.A. [Inonu University, Education Faculty, Computer Education and Educational Technology Department, 44280 Malatya (Turkey); Gencer, H. [Inonu University, Science and Art Faculty, Physics Department, 44280 Malatya (Turkey)

    2015-11-01

    Highlights: • The surface of YIG films were magnetically modulated by magnet array. • The surface modulated YIG films formed sharp band gaps. • A very small magnetic field change leads a large change in the peak value of band gap frequency. - Abstract: In this work, magnetostatic surface spin waves (MSSW) were propagated along the single crystal YIG (Y{sub 3}Fe{sub 5}O{sub 12}) film grown on GGG substrate. In order to obtain magnonic crystals, unlike the conventional methods, the surface of YIG films were magnetically modulated by magnet array in one and two-dimensions. The surface modulated YIG films formed sharp band gaps at approximately 6.55 GHz and 6.58 GHz at 1600 Oe magnetic field for one and two-dimensional magnonic crystals, respectively. It was found that a very small magnetic field change leads a large change in the peak value of band gap frequency.

  5. Surface modification of YIG by magnet array

    International Nuclear Information System (INIS)

    Atalay, S.; Kolat, V.S.; Bakır, H.G.; Izgi, T.; Kaya, A.O.; Kaya, O.A.; Gencer, H.

    2015-01-01

    Highlights: • The surface of YIG films were magnetically modulated by magnet array. • The surface modulated YIG films formed sharp band gaps. • A very small magnetic field change leads a large change in the peak value of band gap frequency. - Abstract: In this work, magnetostatic surface spin waves (MSSW) were propagated along the single crystal YIG (Y 3 Fe 5 O 12 ) film grown on GGG substrate. In order to obtain magnonic crystals, unlike the conventional methods, the surface of YIG films were magnetically modulated by magnet array in one and two-dimensions. The surface modulated YIG films formed sharp band gaps at approximately 6.55 GHz and 6.58 GHz at 1600 Oe magnetic field for one and two-dimensional magnonic crystals, respectively. It was found that a very small magnetic field change leads a large change in the peak value of band gap frequency.

  6. Probing droplets on superhydrophobic surfaces by synchrotron radiation scattering techniques

    KAUST Repository

    Accardo, Angelo

    2014-06-10

    Droplets on artificially structured superhydrophobic surfaces represent quasi contact-free sample environments which can be probed by X-ray microbeams and nanobeams in the absence of obstructing walls. This review will discuss basic surface wettability concepts and introduce the technology of structuring surfaces. Quasi contact-free droplets are compared with contact-free droplets; processes related to deposition and evaporation on solid surfaces are discussed. Droplet coalescence based on the electrowetting effect allows the probing of short-time mixing and reaction processes. The review will show for several materials of biological interest that structural processes related to conformational changes, nucleation and assembly during droplet evaporation can be spatially and temporally resolved by raster-scan diffraction techniques. Orientational ordering of anisotropic materials deposited during solidification at pinning sites facilitates the interpretation of structural data. 2014 International Union of Crystallography.

  7. Magnetic hydroxyapatite coatings as a new tool in medicine: A scanning probe investigation

    International Nuclear Information System (INIS)

    Gambardella, A.; Bianchi, M.; Kaciulis, S.; Mezzi, A.; Brucale, M.; Cavallini, M.; Herrmannsdoerfer, T.; Chanda, G.; Uhlarz, M.; Cellini, A.; Pedna, M.F.; Sambri, V.; Marcacci, M.; Russo, A.

    2016-01-01

    Hydroxyapatite films enriched with magnetite have been fabricated via a Pulsed Plasma Deposition (PPD) system with the final aim of representing a new platform able to disincentivate bacterial adhesion and biofilm formation. The chemical composition and magnetic properties of films were respectively examined by X-ray photoelectron spectroscopy (XPS) and Superconducting Quantum Interference Device (SQUID) measurements. The morphology and conductive properties of the magnetic films were investigated via a combination of scanning probe technologies including atomic force microscopy (AFM), electrostatic force microscopy (EFM), and scanning tunneling microscopy (STM). Interestingly, the range of adopted techniques allowed determining the preservation of the chemical composition and magnetic properties of the deposition target material while STM analysis provided new insights on the presence of surface inhomogeneities, revealing the presence of magnetite-rich islands over length scales compatible with the applications. Finally, preliminary results of bacterial adhesion tests, indicated a higher ability of magnetic hydroxyapatite films to reduce Escherichia coli adhesion at 4 h from seeding compared to control hydroxyapatite films. - Highlights: • Pulsed Plasma Deposition technique is used to deposit magnetite-rich films of hydroxyapatite for antibacterial purposes. • The preservation of the chemical composition and magnetic properties of the deposition target material is demonstrated. • Scanning tunnelling microscopy is employed for the first time to reveal the presence of magnetite-rich states at the surface. • Preliminary tests suggest that Mag HA films hamper the adhesion of Escherichia coli compared to not magnetic films.

  8. Magnetic hydroxyapatite coatings as a new tool in medicine: A scanning probe investigation

    Energy Technology Data Exchange (ETDEWEB)

    Gambardella, A., E-mail: a.gambardella@biomec.ior.it [Laboratorio di NanoBiotecnologie (NaBi), Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, I-40136 Bologna (Italy); Bianchi, M. [Laboratorio di NanoBiotecnologie (NaBi), Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, I-40136 Bologna (Italy); Kaciulis, S.; Mezzi, A.; Brucale, M. [Istituto per lo Studio dei Materiali Nanostrutturati (ISMN), Consiglio Nazionale delle Ricerche, Via Salaria km 29.300, P.O. Box 10, 00015 Monterotondo Staz, Roma (Italy); Cavallini, M. [Magnetic Nanostructures for Spintronics and Nanomedicine, CNR-ISMN, Via Gobetti 101, 40129 Bologna (Italy); Herrmannsdoerfer, T.; Chanda, G.; Uhlarz, M. [Dresden High Magnetic Field Laboratory (HLD-EMFL), Helmholtz-Zentrum Dresden-Rossendorf, D-01314 Dresden (Germany); Cellini, A.; Pedna, M.F. [Unità Operativa Microbiologia Laboratorio Unico del Centro Servizi AUSL della Romagna, Pievesestina, Cesena (Italy); Sambri, V. [Unità Operativa Microbiologia Laboratorio Unico del Centro Servizi AUSL della Romagna, Pievesestina, Cesena (Italy); Dipartimento di Medicina Specialistica, Diagnostica e Sperimentale (DIMES), Università degli Studi di Bologna, Via Zamboni 33, 40126 Bologna (Italy); Marcacci, M.; Russo, A. [Laboratorio di NanoBiotecnologie (NaBi), Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, I-40136 Bologna (Italy); Laboratorio di Biomeccanica ed Innovazione Tecnologica, Istituto Ortopedico Rizzoli, Via di Barbiano1/10, I-40136 Bologna (Italy)

    2016-05-01

    Hydroxyapatite films enriched with magnetite have been fabricated via a Pulsed Plasma Deposition (PPD) system with the final aim of representing a new platform able to disincentivate bacterial adhesion and biofilm formation. The chemical composition and magnetic properties of films were respectively examined by X-ray photoelectron spectroscopy (XPS) and Superconducting Quantum Interference Device (SQUID) measurements. The morphology and conductive properties of the magnetic films were investigated via a combination of scanning probe technologies including atomic force microscopy (AFM), electrostatic force microscopy (EFM), and scanning tunneling microscopy (STM). Interestingly, the range of adopted techniques allowed determining the preservation of the chemical composition and magnetic properties of the deposition target material while STM analysis provided new insights on the presence of surface inhomogeneities, revealing the presence of magnetite-rich islands over length scales compatible with the applications. Finally, preliminary results of bacterial adhesion tests, indicated a higher ability of magnetic hydroxyapatite films to reduce Escherichia coli adhesion at 4 h from seeding compared to control hydroxyapatite films. - Highlights: • Pulsed Plasma Deposition technique is used to deposit magnetite-rich films of hydroxyapatite for antibacterial purposes. • The preservation of the chemical composition and magnetic properties of the deposition target material is demonstrated. • Scanning tunnelling microscopy is employed for the first time to reveal the presence of magnetite-rich states at the surface. • Preliminary tests suggest that Mag HA films hamper the adhesion of Escherichia coli compared to not magnetic films.

  9. Measuring the surface-heating of medical ultrasonic probes

    International Nuclear Information System (INIS)

    Kollmann, Chr; Vacariu, G; Fialka-Moser, V; Bergmann, H

    2004-01-01

    Due to converting losses the probe's surface itself is heated up, especially when emitting into air. Possible temperature increases in an ensemble of 15 different diagnostic and therapeutic ultrasound probes from 7 manufacturers in the frequency range between 0.05-7.5 MHz have been examined. Surface temperatures were detected by means of a calibrated IR-thermographic camera using a scheme of various power and pulse settings, as well as different imaging modalitites as used in clinical routine. Depending on the setup and the output power, the absolute surface temperatures of some of the probes emitting in air can be beyond 43 deg. C within 5-7 min.; a maximum surface temperature of 84 deg. C has been detected. Continuous mode or high pulse repetition frequencies on the therapeutic system side, small focused Doppler modes on the diagnostic system side combined with increased emitted acoustic intensities result in high surface temperatures. Within a worst case scenario a potential risk of negative skin changes (heat damage) or non-optimal therapeutic effects seems to be possible if a therapeutic system is used very often and if its emission continues unintentionally. In general the user should be aware that low emission intensities of e.g. 50 mW cm -2 could already produce hot surfaces

  10. Toxoplasma gondii DNA detection with a magnetic molecular beacon probe

    Science.gov (United States)

    Xu, Shichao; Yao, Cuicui; Wei, Shuoming; Zhang, Jimei; Dai, Zhao; Zheng, Guo; Sun, Bo; Han, Qing; Hu, Fei; Zhou, Hongming

    2008-12-01

    Toxoplasma Gondii infection is widespread in humans worldwide and reported infection rates range from 3%-70%, depending on the populations or geographic areas, and it has been recognized as a potential food safety hazard in our daily life. A magnetic molecular beacon probe (mMBP), based on theory of fluorescence resonance energy transfer (FRET), was currently reported to detect Toxoplasma Gondii DNA. Nano-sized Fe3O4 were primarily prepared by coprecipitation method in aqueous phase with NaOH as precipitator, and was used as magnetic core. The qualified coreshell magnetic quantum dots (mQDs), i.e. CdTe(symbol)Fe3O4, were then achieved by layer-by-layer method when mol ratio of Fe3O4/CdTe is 1/3, pH at 6.0, 30 °C, and reactant solution was refluxed for 30 min, the size of mQDs were determined to be 12-15 nm via transmission electron microscopy (TEM). Over 70% overlap between emission spectrum of mQDs and absorbance spectrum of BHQ-2 was observed, this result suggests the synthesized mQDs and BHQ-2 can be utilized as energy donor and energy acceptor, respectively. The sensing probe was fabricated and a stem-loop Toxoplasma Gondii DNA oligonucleotide was labeled with mQDs at the 5' end and BHQ-2 at 3' end, respectively. Target Toxoplasma gondii DNA was detected under conditions of 37 °C, hybridization for 2h, at pH8.0 in Tris-HCl buffer. About 30% recovery of fluorescence intensity was observed via fluorescence spectrum (FS) after the Toxoplasma gondii DNA was added, which suggested that the Toxoplasma Gondii DNA was successfully detected. Specificity investigation of the mMBP indicated that relative low recovery of fluorescence intensity was obtained when the target DNA with one-base pair mismatch was added, this result indicated the high specificity of the sensing probe. Our research simultaneously indicated that mMBP can be conveniently separated from the unhybridized stem-loop DNA and target DNA, which will be meaningful in DNA sensing and purification process.

  11. Tendamistat surface accessibility to the TEMPOL paramagnetic probe

    Energy Technology Data Exchange (ETDEWEB)

    Scarselli, Maria; Bernini, Andrea; Segoni, Claudia [Universita di Siena, Dipartimento di Biologia Molecolare and Centro per lo Studio Strutturale di Sistemi Biomolecolari (Italy); Molinari, Henriette [Universita di Verona, Istituto Policattedra (Italy); Esposito, Gennaro [Universita di Udine, Dipartimento di Scienze e Tecnologie Biomediche (Italy); Lesk, Arthur M. [University of Cambridge, Department of Haematology (United Kingdom); Laschi, Franco [Universita di Siena, Dipartimento di Chimica (Italy); Temussi, Pierandrea [Universita di Napoli, Dipartimento di Chimica (Italy); Niccolai, Neri [Universita di Siena, Dipartimento di Biologia Molecolare and Centro per lo Studio Strutturale di Sistemi Biomolecolari (Italy)

    1999-10-15

    TEMPOL, the soluble spin-label 4-hydroxy-2,2,6,6-tetramethyl-piperidine-1-oxyl, has been used to determine the surface characteristics of tendamistat, a small protein with a well-characterised structure both in solution and in the crystal. A good correlation has been found between predicted regions of exposed protein surface and the intensity attenuations induced by the probe on 2D NMR TOCSY cross peaks of tendamistat in the paramagnetic water solution. All the high paramagnetic effects have been interpreted in terms of more efficient competition of TEMPOL with water molecules at some surface positions. The active site of tendamistat coincides with the largest surface patch accessible to the probe. A strong hydration of protein N and C termini can also be suggested by this structural approach, as these locations exhibit reduced paramagnetic perturbations. Provided that the solution structure is known, the use of this paramagnetic probe seems to be well suited to delineate the dynamic behaviour of the protein surface and, more generally, to gain relevant information about the molecular presentation processes.

  12. Measurement of steep aspheric surfaces using an anamorphic probe

    International Nuclear Information System (INIS)

    Biswas, Amiya; Coupland, Jeremy

    2008-01-01

    Synthetic aperture interferometry has been previously proposed as a possible in-process method to measure aspheric form (R. Tomlinson, Appl. Opt.42, 701, 2003.APOPAI0003-693510.1364/AO.42.000701). Preliminary demonstration utilized a scanning probe consisting of a pair of bare single mode fibers to perform source and receive functions. It was found that this probe did not have sufficient numerical aperture (NA) to measure steep surfaces and that simply increasing the NA decreases the light gathering efficiency substantially. In this paper, we introduce supplementary optics to increase the NA, and the light gathering efficiency has been increased by adopting an anamorphic design. A spherical test optic of known form is measured to demonstrate the capability of the new probe design

  13. Measurement of steep aspheric surfaces using an anamorphic probe

    Science.gov (United States)

    Biswas, Amiya; Coupland, Jeremy

    2008-04-01

    Synthetic aperture interferometry has been previously proposed as a possible in-process method to measure aspheric form (R. Tomlinson, Appl. Opt.42, 701, 2003.APOPAI0003-693510.1364/AO.42.000701). Preliminary demonstration utilized a scanning probe consisting of a pair of bare single mode fibers to perform source and receive functions. It was found that this probe did not have sufficient numerical aperture (NA) to measure steep surfaces and that simply increasing the NA decreases the light gathering efficiency substantially. In this paper, we introduce supplementary optics to increase the NA, and the light gathering efficiency has been increased by adopting an anamorphic design. A spherical test optic of known form is measured to demonstrate the capability of the new probe design.

  14. Dual-Color Fluorescence Imaging of Magnetic Nanoparticles in Live Cancer Cells Using Conjugated Polymer Probes

    Science.gov (United States)

    Sun, Minjie; Sun, Bin; Liu, Yun; Shen, Qun-Dong; Jiang, Shaojun

    2016-01-01

    Rapid growth in biological applications of nanomaterials brings about pressing needs for exploring nanomaterial-cell interactions. Cationic blue-emissive and anionic green-emissive conjugated polymers are applied as dual-color fluorescence probes to the surface of negatively charged magnetic nanoparticles through sequentially electrostatic adsorption. These conjugated polymers have large extinction coefficients and high fluorescence quantum yield (82% for PFN and 62% for ThPFS). Thereby, one can visualize trace amount (2.7 μg/mL) of fluorescence-labeled nanoparticles within cancer cells by confocal laser scanning microscopy. Fluorescence labeling by the conjugated polymers is also validated for quantitative determination of the internalized nanoparticles in each individual cell by flow cytometry analysis. Extensive overlap of blue and green fluorescence signals in the cytoplasm indicates that both conjugated polymer probes tightly bind to the surface of the nanoparticles during cellular internalization. The highly charged and fluorescence-labeled nanoparticles non-specifically bind to the cell membranes, followed by cellular uptake through endocytosis. The nanoparticles form aggregates inside endosomes, which yields a punctuated staining pattern. Cellular internalization of the nanoparticles is dependent on the dosage and time. Uptake efficiency can be enhanced three-fold by application of an external magnetic field. The nanoparticles are low cytotoxicity and suitable for simultaneously noninvasive fluorescence and magnetic resonance imaging application. PMID:26931282

  15. Probing Magnetic Fields with Square Kilometre Array and its ...

    Indian Academy of Sciences (India)

    /fulltext/joaa/037/04/0042. Keywords. Magnetic fields; telescopes; galaxies: magnetic fields; ISM: magnetic fields; stars: magnetic fields; turbulence. Abstract. Origin of magnetic fields, its structure and effects on dynamical processes in stars to ...

  16. Standard Practices for Usage of Inductive Magnetic Field Probes with Application to Electric Propulsion Testing

    Science.gov (United States)

    Polzin, Kurt A.; Hill, Carrie S.; Turchi, Peter J.; Burton, Rodney L.; Messer, Sarah; Lovberg, Ralph H.; Hallock, Ashley K.

    2013-01-01

    Inductive magnetic field probes (also known as B-dot probes and sometimes as B-probes or magnetic probes) are often employed to perform field measurements in electric propulsion applications where there are time-varying fields. Magnetic field probes provide the means to measure these magnetic fields and can even be used to measure the plasma current density indirectly through the application of Ampere's law. Measurements of this type can yield either global information related to a thruster and its performance or detailed, local data related to the specific physical processes occurring in the plasma. Results of the development of a standard for B-dot probe measurements are presented, condensing the available literature on the subject into an accessible set of rules, guidelines, and techniques to standardize the performance and presentation of future measurements.

  17. Surface acoustic wave probe implant for predicting epileptic seizures

    Science.gov (United States)

    Gopalsami, Nachappa [Naperville, IL; Kulikov, Stanislav [Sarov, RU; Osorio, Ivan [Leawood, KS; Raptis, Apostolos C [Downers Grove, IL

    2012-04-24

    A system and method for predicting and avoiding a seizure in a patient. The system and method includes use of an implanted surface acoustic wave probe and coupled RF antenna to monitor temperature of the patient's brain, critical changes in the temperature characteristic of a precursor to the seizure. The system can activate an implanted cooling unit which can avoid or minimize a seizure in the patient.

  18. Surface potential modeling and reconstruction in Kelvin probe force microscopy.

    Science.gov (United States)

    Xu, Jie; Wu, Yangqing; Li, Wei; Xu, Jun

    2017-09-08

    Kelvin probe force microscopy (KPFM) measurement has been extensively applied in metallic, semiconductor and organic electronic or photovoltaic devices, to characterize the local contact potential difference or surface potential of the samples at the nanoscale. Here, a comprehensive modeling of surface potential in KPFM is established, from the well-known single capacitance model to a precise electrodynamic model, considering the long range property of the electrostatic force in KPFM. The limitations and relations of different models are also discussed. Besides, the feedback condition of the KPFM system is reconsidered and modified, showing that the influence of the cantilever has been overestimated by about 20% in previous reports. Afterwards, the surface potential of charged Si-nanocrystals is reconstructed based on the electrodynamic model, and the calculated surface charge density is very consistent with the macroscopic capacitance-voltage (C-V) measurement. A deep understanding and correct reconstruction of surface potential is crucial to the quantitative analysis of KPFM results.

  19. Probing photospheric magnetic fields with new spectral line pairs

    Science.gov (United States)

    Smitha, H. N.; Solanki, S. K.

    2017-12-01

    Context. The magnetic line ratio (MLR) method has been extensively used in the measurement of photospheric magnetic field strength. It was devised for the neutral iron line pair at 5247.1 Å and 5250.2 Å (5250 Å pair). Other line pairs as well-suited as this pair have not been reported in the literature. Aims: The aim of the present work is to identify new line pairs useful for the MLR technique and to test their reliability. Methods: We used a three-dimensional magnetohydrodynamic 3D MHD simulation representing the quiet Sun atmosphere to synthesize the Stokes profiles. Then, we applied the MLR technique to the Stokes V profiles to recover the fields in the MHD cube both at original resolution and after degrading with a point spread function. In both these cases, we aim to empirically represent the field strengths returned by the MLR method in terms of the field strengths in the MHD cube. Results: We have identified two new line pairs that are very well adapted to be used for MLR measurements. The first pair is in the visible, Fe I 6820-6842 Å, whose intensity profiles have previously been used to measure stellar magnetic fields, and the other pair is in the infrared (IR), Fe I 15 534-15 542 Å. The lines in these pairs reproduce the magnetic fields in the MHD cube rather well and, in fact, somewhat better than the original 5250 Å pair. Conclusions: The newly identified line pairs complement the old pairs. The lines in the new IR pair, because of their higher Zeeman sensitivity, are ideal for the measurement of weak fields. The new visible pair works best above 300 G. The new IR pair, due to its large Stokes V signal samples more fields in the MHD cube than the old IR pair at 1.56 μm, even in the presence of noise, and hence likely also on the real Sun. Owing to their low formation heights (100-200 km above τ5000 = 1), both the new line pairs are well suited for probing magnetic fields in the lower photosphere.

  20. Neutron scattering on magnetic surfaces

    International Nuclear Information System (INIS)

    Ott, F.

    2007-01-01

    During the early eighties, advanced techniques for the deposition of ultra-thin metal films were developed. The combination of different types of materials gave rise to new physical phenomena such as the magnetic exchange coupling in superlattices or the exchange bias between ferro and anti-ferro layers. New types of heterostructures combining magnetic oxides, insulating oxides or magnetic semiconductors are still being developed. Alongside the fabrication of these new meta-materials made of thin films stacking, polarized neutron reflectometry has emerged as a routine tool for the characterization of magnetic hetero-structures. In the recent years, the new developments of polarized reflectivity have been connected to the study of micro- and nano-structures, especially micro-magnetic structures in multilayers. The technique of off-specular scattering has been developed for the study of the roughness or the micro magnetism at a micro metric scale. For the study of nano-metric structures, in the range below 100 nm, grazing incidence Small Angle Scattering is being considered. In thin films, the volume of magnetic matter is very small but nevertheless, diffraction experiments can be performed owing to the good performances of modern neutron spectrometers

  1. Scanning probe manipulation of magnetism at the LaAlO3/SrTiO3 heterointerface.

    Science.gov (United States)

    Kalisky, Beena; Bert, Julie A; Bell, Christopher; Xie, Yanwu; Sato, Hiroki K; Hosoda, Masayuki; Hikita, Yasuyuki; Hwang, Harold Y; Moler, Kathryn A

    2012-08-08

    Manipulation of magnetism is a longstanding goal of research in exotic materials. In this work, we demonstrate that the small ferromagnetic patches in LaAlO(3)/SrTiO(3) heterostructures can be dramatically changed by in situ contact of a scanning probe. Our results provide a platform for manipulation of small magnets through either a strong magneto-elastic coupling or sensitivity to surface modification. The ability to locally control magnetism is particularly interesting due to the presence of superconductivity with strong spin-orbit coupling in LaAlO(3)/SrTiO(3).

  2. Surface magnetism of gallium arsenide nanofilms

    Science.gov (United States)

    Lu, Huan; Yu, Jin; Guo, Wanlin

    2017-11-01

    Gallium arsenide (GaAs) is the most widely used second-generation semiconductor with a direct band gap, and it is being increasingly used as nanofilms. However, the magnetic properties of GaAs nanofilms have never been studied. Here we find by comprehensive density-functional-theory calculations that GaAs nanofilms cleaved along the 〈111 〉 and 〈100 〉 directions become intrinsically metallic films with strong surface magnetism and the magnetoelectric effect. Surface magnetism and electrical conductivity are realized via a combined effect of charge transfer induced by spontaneous electric polarization through the film thickness and spin-polarized surface states. The surface magnetism of 〈111 〉 nanofilms can be significantly and linearly tuned by a vertically applied electric field, endowing the nanofilms with unexpectedly high magnetoelectric coefficients, which are tens of times higher than those of ferromagnetic metals and transition-metal oxides.

  3. Neutron scattering on magnetic surfaces

    Science.gov (United States)

    Ott, Frédéric

    2007-09-01

    During the early 1980s, advanced techniques for the deposition of ultra-thin metal films were developed. The combination of different types of materials gave rise to new physical phenomena such as the magnetic exchange coupling in superlattices or the exchange bias between ferro and anti-ferro layers. The field was very active because of the associated industrial applications in magnetic field sensors. New types of heterostructures combining magnetic oxides, insulating oxides or magnetic semiconductors are still being developed. Alongside the fabrication of these new meta-materials made of thin films stacking, polarized neutron reflectometry has emerged as a routine tool for the characterization of magnetic hetero-structures. In the recent years, the new developments of polarized reflectivity have been connected to the study of micro and nanostructures, especially micromagnetic structures in multilayers. The technique of off-specular scattering has been developed for the study of the roughness or the micromagnetism at a micrometric scale. For the study of nanometric structures, in the range below 100 nm, grazing incidence Small Angle Scattering is being considered. To cite this article: F. Ott, C. R. Physique 8 (2007).

  4. Homogeneous protein analysis by magnetic core-shell nanorod probes

    KAUST Repository

    Schrittwieser, Stefan

    2016-03-29

    Studying protein interactions is of vital importance both to fundamental biology research and to medical applications. Here, we report on the experimental proof of a universally applicable label-free homogeneous platform for rapid protein analysis. It is based on optically detecting changes in the rotational dynamics of magnetically agitated core-shell nanorods upon their specific interaction with proteins. By adjusting the excitation frequency, we are able to optimize the measurement signal for each analyte protein size. In addition, due to the locking of the optical signal to the magnetic excitation frequency, background signals are suppressed, thus allowing exclusive studies of processes at the nanoprobe surface only. We study target proteins (soluble domain of the human epidermal growth factor receptor 2 - sHER2) specifically binding to antibodies (trastuzumab) immobilized on the surface of our nanoprobes and demonstrate direct deduction of their respective sizes. Additionally, we examine the dependence of our measurement signal on the concentration of the analyte protein, and deduce a minimally detectable sHER2 concentration of 440 pM. For our homogeneous measurement platform, good dispersion stability of the applied nanoprobes under physiological conditions is of vital importance. To that end, we support our measurement data by theoretical modeling of the total particle-particle interaction energies. The successful implementation of our platform offers scope for applications in biomarker-based diagnostics as well as for answering basic biology questions.

  5. Ultrasmall superparamagnetic iron oxide (USPIO)-based liposomes as magnetic resonance imaging probes.

    Science.gov (United States)

    Frascione, Daniela; Diwoky, Clemens; Almer, Gunter; Opriessnig, Peter; Vonach, Caroline; Gradauer, Kerstin; Leitinger, Gerd; Mangge, Harald; Stollberger, Rudolf; Prassl, Ruth

    2012-01-01

    Magnetic liposomes (MLs) are phospholipid vesicles that encapsulate magnetic and/or paramagnetic nanoparticles. They are applied as contrast agents for magnetic resonance imaging (MRI). MLs have an advantage over free magnetic nanocores, in that various functional groups can be attached to the surface of liposomes for ligand-specific targeting. We have synthesized PEG-coated sterically-stabilized magnetic liposomes (sMLs) containing ultrasmall superparamagnetic iron oxides (USPIOs) with the aim of generating stable liposomal carriers equipped with a high payload of USPIOs for enhanced MRI contrast. Regarding iron oxide nanoparticles, we have applied two different commercially available surface-coated USPIOs; sMLs synthesized and loaded with USPIOs were compared in terms of magnetization and colloidal stability. The average diameter size, morphology, phospholipid membrane fluidity, and the iron content of the sMLs were determined by dynamic light scattering (DLS), transmission electron microscopy (TEM), fluorescence polarization, and absorption spectroscopy, respectively. A colorimetric assay using potassium thiocyanate (KSCN) was performed to evaluate the encapsulation efficiency (EE%) to express the amount of iron enclosed into a liposome. Subsequently, MRI measurements were carried out in vitro in agarose gel phantoms to evaluate the signal enhancement on T1- and T2-weighted sequences of sMLs. To monitor the biodistribution and the clearance of the particles over time in vivo, sMLs were injected in wild type mice. DLS revealed a mean particle diameter of sMLs in the range between 100 and 200 nm, as confirmed by TEM. An effective iron oxide loading was achieved just for one type of USPIO, with an EE% between 74% and 92%, depending on the initial Fe concentration (being higher for lower amounts of Fe). MRI measurements demonstrated the applicability of these nanostructures as MRI probes. Our results show that the development of sMLs is strictly dependent on the

  6. Magnetic surfaces and neoclassical transport in stellarators

    International Nuclear Information System (INIS)

    Ng, K.C.

    1987-06-01

    This paper studies the structure of a stellarator field and the confinement of a high temperature plasma in toroidal geometry. A field line tracing program is developed to explore the structure of magnetic fields on a fine scale so as to explain anomalous electron transport. The model magnetic field chosen has a simple analytic representation which is easy to compute, so that the field lines can be integrated to a high accuracy. In a typical case most of the magnetic surfaces are well behaved on the scale of the gyroradius of the electron, rho/sub e/, even when the magnetic field has no 2d symmetry. Island chains or stochastic regions are formed in the vicinity of magnetic surfaces with rational rotational transform iota = n/m. It is shown that the island with w decays exponentially with m. Results suggest that the anomalous electron transport observed in experiments may be due to the presence of an ambipolar electrostatic potential phi. This hypothesis is proven by computing the guiding center orbits of the electrons and estimating island widths of the drift surfaces that are swept out. It is shown that with a small electric potential depending on the toroidal and poloidal angles, the drift surface island width w is an order of magnitude larger than that of the magnetic surfaces and decays exponentially at a slower rate

  7. Surface magnetic enhancement for coal cleaning

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, J.Y.

    1988-01-01

    The progress achieved during this quarter includes the reagent shelf life study, the evaluation and selection of magnetizing reagents, an experimental database for activating and depressing the adsorption of magnetizing reagents in the presence of various chemicals, an adsorption regulator investigation, the establishment of a coal surface controlling theory, and a magnetite size effect study for the separation of magnetic enhanced minerals. The work is on schedule with the original plan. Modifications include the addition of a regulator study to help proving the selectivity controlling theory. The fundamentals for applying the magnetizing reagent technology on coal cleaning are generally established during this quarter. Selective magnetic enhancement of minerals through the adsorption of magnetizing reagents has been experimentally proved. The work for the next quarter will be mainly on optimizing the selective adsorption conditions and the continuation on magnetite size effect study.

  8. Extremal surfaces as bulk probes in AdS/CFT

    Science.gov (United States)

    Hubeny, Veronika E.

    2012-07-01

    Motivated by the need for further insight into the emergence of AdS bulk spacetime from CFT degrees of freedom, we explore the behaviour of probes represented by specific geometric quantities in the bulk. We focus on geodesics and n-dimensional extremal surfaces in a general static asymptotically AdS spacetime with spherical and planar symmetry, respectively. While our arguments do not rely on the details of the metric, we illustrate some of our findings explicitly in spacetimes of particular interest (specifically AdS, Schwarzschild-AdS and extreme Reissner-Nordstrom-AdS). In case of geodesics, we find that for a fixed spatial distance between the geodesic endpoints, spacelike geodesics at constant time can reach deepest into the bulk. We also present a simple argument for why, in the presence of a black hole, geodesics cannot probe past the horizon whilst anchored on the AdS boundary at both ends. The reach of an extremal n-dimensional surface anchored on a given region depends on its dimensionality, the shape and size of the bounding region, as well as the bulk metric. We argue that for a fixed extent or volume of the boundary region, spherical regions give rise to the deepest reach of the corresponding extremal surface. Moreover, for physically sensible spacetimes, at fixed extent of the boundary region, higher-dimensional surfaces reach deeper into the bulk. Finally, we show that in a static black hole spacetime, no extremal surface (of any dimensionality, anchored on any region in the boundary) can ever penetrate the horizon.

  9. Magnetism and Superconductivity in Iron-based Superconductors as Probed by Nuclear Magnetic Resonance

    CERN Document Server

    Hammerath, Franziska

    2012-01-01

    Nuclear Magnetic Resonance (NMR) has been a fundamental player in the studies of superconducting materials for many decades. This local probe technique allows for the study of the static electronic properties as well as of the low energy excitations of the electrons in the normal and the superconducting state. On that account it has also been widely applied to Fe-based superconductors from the very beginning of their discovery in February 2008. This dissertation comprises some of these very first NMR results, reflecting the unconventional nature of superconductivity and its strong link to magnetism in the investigated compounds LaO1–xFxFeAs and LiFeAs.

  10. Probing and Mapping Electrode Surfaces in Solid Oxide Fuel Cells

    Science.gov (United States)

    Blinn, Kevin S.; Li, Xiaxi; Liu, Mingfei; Bottomley, Lawrence A.; Liu, Meilin

    2012-01-01

    Solid oxide fuel cells (SOFCs) are potentially the most efficient and cost-effective solution to utilization of a wide variety of fuels beyond hydrogen 1-7. The performance of SOFCs and the rates of many chemical and energy transformation processes in energy storage and conversion devices in general are limited primarily by charge and mass transfer along electrode surfaces and across interfaces. Unfortunately, the mechanistic understanding of these processes is still lacking, due largely to the difficulty of characterizing these processes under in situ conditions. This knowledge gap is a chief obstacle to SOFC commercialization. The development of tools for probing and mapping surface chemistries relevant to electrode reactions is vital to unraveling the mechanisms of surface processes and to achieving rational design of new electrode materials for more efficient energy storage and conversion2. Among the relatively few in situ surface analysis methods, Raman spectroscopy can be performed even with high temperatures and harsh atmospheres, making it ideal for characterizing chemical processes relevant to SOFC anode performance and degradation8-12. It can also be used alongside electrochemical measurements, potentially allowing direct correlation of electrochemistry to surface chemistry in an operating cell. Proper in situ Raman mapping measurements would be useful for pin-pointing important anode reaction mechanisms because of its sensitivity to the relevant species, including anode performance degradation through carbon deposition8, 10, 13, 14 ("coking") and sulfur poisoning11, 15 and the manner in which surface modifications stave off this degradation16. The current work demonstrates significant progress towards this capability. In addition, the family of scanning probe microscopy (SPM) techniques provides a special approach to interrogate the electrode surface with nanoscale resolution. Besides the surface topography that is routinely collected by AFM and STM

  11. Evaluation of disturbed magnetic surfaces with fractal dimensions

    International Nuclear Information System (INIS)

    Mishimagi, Shigehiro; Yoshii, Keiichi; Kogoshi, Sumio; Maeda, Joji

    1998-01-01

    For collapsed magnetic surfaces that are produced by overlapping of two magnetic islands, the fractal dimension can effectively estimate the degradation of them. The fractal dimensions of cross sections of regular magnetic surfaces and clear magnetic islands are nearly 1, while that of a collapsed magnetic surface is more than 1.2 in the present study. The Lyapunov exponents and dimensions are also calculated, which suggest the behavior of the field line of the collapsed magnetic surface is chaos. (author)

  12. Critical phenomena in magnetic vortex formation probed by noise spectroscopy

    International Nuclear Information System (INIS)

    Saitoh, E.; Harii, K.; Miyajima, H.; Yamaoka, T.

    2004-01-01

    Transition between a vortex magnetic state and a uniform magnetic state in a Ni 81 Fe 19 mesoscopic ring has been investigated in terms of resistive-noise spectroscopy. The observed low-frequency noise exhibits critical enhancement around the magnetization saturation. This noise enhancement can be argued from the viewpoint of the critical phenomena due to the chiral-symmetry breakdown of mesoscopic magnetic-structure, which can present a typical mechanism of symmetry transition of magnetic structure in mesoscopic ferromagnets

  13. Sealed magic angle spinning nuclear magnetic resonance probe and process for spectroscopy of hazardous samples

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Herman M.; Washton, Nancy M.; Mueller, Karl T.; Sears, Jr., Jesse A.; Townsend, Mark R.; Ewing, James R.

    2016-06-14

    A magic-angle-spinning (MAS) nuclear magnetic resonance (NMR) probe is described that includes double containment enclosures configured to seal and contain hazardous samples for analysis. The probe is of a modular design that ensures containment of hazardous samples during sample analysis while preserving spin speeds for superior NMR performance and convenience of operation.

  14. Batch fabrication of scanning microscopy probes for thermal and magnetic imaging using standard micromachining

    NARCIS (Netherlands)

    Sarajlic, Edin; Vermeer, Rolf; Delalande, M.Y.; Siekman, Martin Herman; Huijink, R.; Fujita, H.; Abelmann, Leon

    2010-01-01

    We present a process for batch fabrication of a novel scanning microscopy probe for thermal and magnetic imaging using standard micromachining and conventional optical contact lithography. The probe features an AFM-type cantilever with a sharp pyramidal tip composed of four freestanding silicon

  15. SURFACE MODIFITED MAGNETIC NANOPARTICLES FOR BIOMEDICAL APPLICATION

    Directory of Open Access Journals (Sweden)

    G. Yu. Vasyukov

    2014-01-01

    Full Text Available Unique physicochemical properties of nanomaterials arouse a great interest of specialists of various fields. Materials based on nanostructures purchase new mechanical, optical, and electrical properties. Great practical importance is the magnetic properties of materials, structural elements which lie at the nanoscale. Nanomaterials with magnetic properties have been used in drug delivery, magnetic hyperthermia, magnetic separation, and magnetic resonance imaging. Magnetic properties of nanoparticles depend on many factors, such as particle size and shape, chemical properties and lattice type. Magnetic characteristics can be changed by the interaction of particles with the surrounding matrix and neighboring particles.Unfortunately, many studies show that a great disadvantage of the unmodified nanoparticles is their non-specific interaction with the cells, which leads to their accumulation outside the target organs, also to­xicity of nanomaterials and their low colloidal stability. Surface modification of nanoparticles can solve this problem. Development of nanostructures based on magnetic nanoparticles and functionalized by biocompatible agents is one of the main targets of nanobiotechnology.

  16. Fluorescent Magnetic Bioprobes by Surface Modification of Magnetite Nanoparticles

    Directory of Open Access Journals (Sweden)

    Tito Trindade

    2013-07-01

    Full Text Available Bimodal nanoprobes comprising both magnetic and optical functionalities have been prepared via a sequential two-step process. Firstly, magnetite nanoparticles (MNPs with well-defined cubic shape and an average dimension of 80 nm were produced by hydrolysis of iron sulfate and were then surface modified with silica shells by using the sol-gel method. The Fe3O4@SiO2 particles were then functionalized with the fluorophore, fluorescein isothiocyanate (FITC, mediated by assembled shells of the cationic polyelectrolyte, polyethyleneimine (PEI. The Fe3O4 functionalized particles were then preliminary evaluated as fluorescent and magnetic probes by performing studies in which neuroblast cells have been contacted with these nanomaterials.

  17. Numerical simulation of directivity for angle probe and surface defect

    International Nuclear Information System (INIS)

    Nam, Young Hyun

    1995-01-01

    An ultrasonic testing uses the directivity of the ultrasonic wave which propagates in one direction. The directivity is expressed as the relationship between the propagate direction and i ts sound pressure. This paper studied the directivity of shear waves emitted from angle probes and scattered from surface defects by using visualization method. These experimental results were compared with the theory which was based on the continuous wave. The applicability of continuous wave theory was discussed in terms of the parameter d/λ where d is transducer or defect size and λ is the wavelength. In the case of angle probes, the experimental results show good agreement with theoretical directivity on the principal lobe. When defect size was smaller than the wavelengths, clear directivity in the reflected wave was observed. In the case of the same ratio of defect size to wavelength, the directivity of reflected waves from the defect show almost the same directivity in spite of frequency differences. When the d/λ is greater than 1.5, measured directivities almost agreed with the theoretical one.

  18. Quantitatively Probing the Means of Controlling Nanoparticle Assembly on Surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Patete, J.m.; Wong, S.; Peng, X.; Serafin, J.M.

    2011-05-17

    As a means of developing a simple, cost-effective, and reliable method for probing nanoparticle behavior, we have used atomic force microscopy to gain a quantitative 3D visual representation of the deposition patterns of citrate-capped Au nanoparticles on a substrate as a function of (a) sample preparation, (b) the choice of substrate, (c) the dispersion solvent, and (d) the number of loading steps. Specifically, we have found that all four parameters can be independently controlled and manipulated in order to alter the resulting pattern and quantity of as-deposited nanoparticles. From these data, the sample preparation technique appears to influence deposition patterns most broadly, and the dispersion solvent is the most convenient parameter to use in tuning the quantity of nanoparticles deposited onto the surface under spin-coating conditions. Indeed, we have quantitatively measured the effect of surface coverage for both mica and silicon substrates under preparation techniques associated with (i) evaporation under ambient air, (ii) heat treatment, and (iii) spin-coating preparation conditions. In addition, we have observed a decrease in nanoparticle adhesion to a substrate when the ethylene glycol content of the colloidal dispersion solvent is increased, which had the effect of decreasing interparticle-substrate interactions. Finally, we have shown that substrates prepared by these diverse techniques have potential applicability in surface-enhanced Raman spectroscopy.

  19. Quantitatively Probing the Means of Controlling Nanoparticle Assembly on Surfaces

    International Nuclear Information System (INIS)

    Patete, J.M.; Wong, S.; Peng, X.; Serafin, J.M.

    2011-01-01

    As a means of developing a simple, cost-effective, and reliable method for probing nanoparticle behavior, we have used atomic force microscopy to gain a quantitative 3D visual representation of the deposition patterns of citrate-capped Au nanoparticles on a substrate as a function of (a) sample preparation, (b) the choice of substrate, (c) the dispersion solvent, and (d) the number of loading steps. Specifically, we have found that all four parameters can be independently controlled and manipulated in order to alter the resulting pattern and quantity of as-deposited nanoparticles. From these data, the sample preparation technique appears to influence deposition patterns most broadly, and the dispersion solvent is the most convenient parameter to use in tuning the quantity of nanoparticles deposited onto the surface under spin-coating conditions. Indeed, we have quantitatively measured the effect of surface coverage for both mica and silicon substrates under preparation techniques associated with (i) evaporation under ambient air, (ii) heat treatment, and (iii) spin-coating preparation conditions. In addition, we have observed a decrease in nanoparticle adhesion to a substrate when the ethylene glycol content of the colloidal dispersion solvent is increased, which had the effect of decreasing interparticle-substrate interactions. Finally, we have shown that substrates prepared by these diverse techniques have potential applicability in surface-enhanced Raman spectroscopy.

  20. Preparation and characterization of a magnetic and optical dual-modality molecular probe

    Science.gov (United States)

    Bumb, A.; Regino, C. A. S.; Perkins, M. R.; Bernardo, M.; Ogawa, M.; Fugger, L.; Choyke, P. L.; Dobson, P. J.; Brechbiel, M. W.

    2010-04-01

    Multi-modality imaging probes combine the advantages of individual imaging techniques to yield highly detailed anatomic and molecular information in living organisms. Herein, we report the synthesis and characterization of a dual-modality nanoprobe that couples the magnetic properties of ultrasmall superparamagnetic iron oxide nanoparticles (USPIOs) with the near infrared fluorescence of Cy5.5. The fluorophore is encapsulated in a biocompatible shell of silica surrounding the iron oxide core for a final diameter of ~ 17 nm. This silica-coated iron oxide nanoparticle (SCION) has been analyzed by transmission electron microscopy, dynamic light scattering, and superconducting quantum interference device (SQUID). The particle demonstrates a strong negative surface charge and maintains colloidal stability in the physiological pH range. Magnetic hysteresis analysis confirms superparamagnetic properties that could be manipulated for thermotherapy. The viability of primary human monocytes, T cells, and B cells incubated with the particle has been examined in vitro. In vivo analysis of agent leakage into subcutaneous A431 tumors in mice was also conducted. This particle has been designed for diagnostic application with magnetic resonance and fluorescence imaging, and has future potential to serve as a heat-sensitive targeted drug delivery platform.

  1. Preparation and characterization of a magnetic and optical dual-modality molecular probe

    Energy Technology Data Exchange (ETDEWEB)

    Bumb, A; Brechbiel, M W [Radioimmune and Inorganic Chemistry Section, Radiation Oncology Branch, NCI, NIH, Building 10, Room 1B53, 10 Center Drive, Bethesda, MD 20892 (United States); Regino, C A S; Ogawa, M; Choyke, P L [Molecular Imaging Program, NCI, NIH, Building 10, Room B3B69, 10 Center Drive, Bethesda, MD 20892 (United States); Perkins, M R [Vaccine Research Center, NIAID, NIH, Building 40, Room 3608B, 40 Convent Drive, Bethesda, MD 20892 (United States); Bernardo, M [SAIC-Frederick Inc., NCI-Frederick, Frederick, MD 21702 (United States); Fugger, L [MRC Human Immunology Unit, Weatherall Institute of Molecular Medicine, John Radcliffe Hospital, The University of Oxford, Oxford OX3 9DS (United Kingdom); Dobson, P J, E-mail: Bumba@mail.nih.gov, E-mail: martinwb@mail.nih.gov [Oxford University Begbroke Science Park, Sandy Lane, Kidlington, Oxon OX5 1PF (United Kingdom)

    2010-04-30

    Multi-modality imaging probes combine the advantages of individual imaging techniques to yield highly detailed anatomic and molecular information in living organisms. Herein, we report the synthesis and characterization of a dual-modality nanoprobe that couples the magnetic properties of ultrasmall superparamagnetic iron oxide nanoparticles (USPIOs) with the near infrared fluorescence of Cy5.5. The fluorophore is encapsulated in a biocompatible shell of silica surrounding the iron oxide core for a final diameter of {approx} 17 nm. This silica-coated iron oxide nanoparticle (SCION) has been analyzed by transmission electron microscopy, dynamic light scattering, and superconducting quantum interference device (SQUID). The particle demonstrates a strong negative surface charge and maintains colloidal stability in the physiological pH range. Magnetic hysteresis analysis confirms superparamagnetic properties that could be manipulated for thermotherapy. The viability of primary human monocytes, T cells, and B cells incubated with the particle has been examined in vitro. In vivo analysis of agent leakage into subcutaneous A431 tumors in mice was also conducted. This particle has been designed for diagnostic application with magnetic resonance and fluorescence imaging, and has future potential to serve as a heat-sensitive targeted drug delivery platform.

  2. Theory of magnetism application to surface physics

    CERN Document Server

    Diep, Hung T

    2014-01-01

    The book is intended for graduate students and researchers who wish to master the main properties of magnetic materials in the bulk state and at the nanometric scale such as for thin films and multilayers. This textbook provides the theories and methods of simulation to study and to understand these properties in an explicit manner. In the first part of the book, the quantum theory of magnetism is presented while the second part of the book is devoted to the application of the theory of magnetism to surface physics. Numerous examples covering typical cases in ferromagnets, antiferromagnets, ferrimagnets, helimagnets, and frustrated spin systems are all illustrated. Fundamental surface effects are shown and discussed. Lastly, the spin transport is described — in which the basic formulation of the Boltzmann's equation is recalled — and the recent methods of Monte Carlo simulation to deal with the spin resistivity are explained. This book contains a large number of detailed solutions for the problems given ...

  3. A portable Hall magnetometer probe for characterization of magnetic iron oxide nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, Jefferson F.D.F.; Costa, Mateus C.; Louro, Sonia R.W.; Bruno, Antonio C., E-mail: acbruno@puc-rio.br

    2017-03-15

    We have built a portable Hall magnetometer probe, for measuring magnetic properties of iron oxide nanoparticles, that can be used for bulk materials and liquid samples as well. The magnetometer probe consists of four voltage-programmable commercial Hall sensors and a thin acrylic plate for positioning the sensors. In order to operate, it needs to be attached to a pole of an electromagnet and connected to an AD converter and a computer. It acquires a complete magnetization curve in a couple of minutes and has a magnetic moment sensitivity of 3.5×10{sup −7} Am{sup 2}. We tested its performance with magnetic nanoparticles containing an iron oxide core and having coating layers with different sizes. The magnetization results obtained were compared with measurements performed on commercial stand-alone magnetometers, and exhibited errors of about ±0.2 Am{sup 2}/kg (i.e 0.4%) at saturation and below 0.5 Am{sup 2}/kg (i.e. 10%) at remanence. - Highlights: • A low-cost portable Hall magnetometer probe has been built. • The Hall magnetometer probe can be attached to any electromagnet. • The Hall probe was calibrated and successfully compared to industry standard magnetometers. • The Hall probe was able to measure iron oxide nanoparticles with different coatings.

  4. Novel cylindrical probe for measuring ion temperature in magnetized plasmas

    Czech Academy of Sciences Publication Activity Database

    Tierens, W.; Komm, Michael; Stöckel, Jan; Van Oost, G.

    2010-01-01

    Roč. 50, č. 9 (2010), s. 841-846 ISSN 0863-1042 R&D Projects: GA ČR GA202/07/0044 Institutional research plan: CEZ:AV0Z20430508 Keywords : PIC * particle-in-cell * simulation * ion temperature * cylindrical probe * STP * segmented tunnel probe * non-thermal plasma Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.006, year: 2010 http://onlinelibrary.wiley.com/doi/10.1002/ctpp.201010143/abstract

  5. Radicals as EPR probes of magnetization of gadolinium stearate Langmuir-Blodgett film

    DEFF Research Database (Denmark)

    Koksharov, Y.A.; Bykov, I.V.; Malakho, A.P.

    2002-01-01

    In the present work we have applied the method of the EPR spin probes which allows performing simultaneously EPR and magnetization measurements to the investigation of magnetism of the Cid stearate Langmuir-Blodgett (LB) films. For this purpose we have prepared and studied by the EPR technique...

  6. Determination of the plasma column shape in the Tokamak Novillo cross section by magnetic probes

    International Nuclear Information System (INIS)

    Hernandez Omana, A.

    1993-01-01

    The determination of plasma cross section shape in Tokamaks is an important diagnostic method for equilibrium conditions analysis. In this work, it is obtained a time dependent variation of the plasma column cross section in Novillo Tokamak. The experimental method is based on using one magnetic probe, which is installed inside of the vacuum vessel in a 1 mm. wall thickness stainless steel tube, in the protected region of the limiter shadow. The plasma column cross section is determined measuring the poloidal magnetic field produced by the plasma current. This method, now running for determining the plasma column shape, requires the measurement of magnetic present field outside plasma column. The measurements are carried out from a set of small coils, which are located inside the vacuum chamber in the radial and poloidal direction, so we can measure magnetic field with no current attenuations produced by the penetration time of the stainless steel vacuum chamber. The magnetic probe detect a real time variation of magnetic flux passing through them. In order to obtain the magnetic field values, it is required that the electric signals coming from the magnetic probe be integrated, this operation is carried out by active circuits located between the probe signal and one oscilloscope. The integrated signals can be exhibited photographed on the oscilloscope display. (Author)

  7. Interactions between protein coated particles and polymer surfaces studied with the rotating particles probe.

    Science.gov (United States)

    Kemper, M; Spridon, D; van IJzendoorn, L J; Prins, M W J

    2012-05-29

    Nonspecific interactions between proteins and polymer surfaces have to be minimized in order to control the performance of biosensors based on immunoassays with particle labels. In this paper we investigate these nonspecific interactions by analyzing the response of protein coated magnetic particles to a rotating magnetic field while the particles are in nanometer vicinity to a polymer surface. We use the fraction of nonrotating (bound) particles as a probe for the interaction between the particles and the surface. As a model system, we study the interaction of myoglobin coated particles with oxidized polystyrene surfaces. We measure the interaction as a function of the ionic strength of the solution, varying the oxidation time of the polystyrene and the pH of the solution. To describe the data we propose a model in which particles bind to the polymer by crossing an energy barrier. The height of this barrier depends on the ionic strength of the solution and two interaction parameters. The fraction of nonrotating particles as a function of ionic strength shows a characteristic shape that can be explained with a normal distribution of energy barrier heights. This method to determine interaction parameters paves the way for further studies to quantify the roles of protein coated particles and polymers in their mutual nonspecific interactions in different matrixes.

  8. Probing High Temperature Superconductors with Magnetometry in Ultrahigh Magnetic Fields

    Energy Technology Data Exchange (ETDEWEB)

    Li, Lu [Univ. of Michigan, Ann Arbor, MI (United States)

    2017-07-26

    The objective of this research is to investigate the high-field magnetic properties of high temperature superconductors, materials that conduct electricity without loss. A technique known as high-resolution torque magnetometry that was developed to directly measure the magnetization of high temperature superconductors. This technique was implemented using the 65 Tesla pulsed magnetic field facility that is part of the National High Magnetic Field Laboratory at Los Alamos National Laboratory. This research addressed unanswered questions about the interplay between magnetism and superconductivity, determine the electronic structure of high temperature superconductors, and shed light on the mechanism of high temperature superconductivity and on potential applications of these materials in areas such as energy generation and power transmission. Further applications of the technology resolve the novel physical phenomena such as correlated topological insulators, and spin liquid state in quantum magnets.

  9. Nanoscale magnetic field mapping with a single spin scanning probe magnetometer

    Energy Technology Data Exchange (ETDEWEB)

    Rondin, L.; Tetienne, J.-P.; Spinicelli, P.; Roch, J.-F.; Jacques, V. [Laboratoire de Photonique Quantique et Moleculaire, Ecole Normale Superieure de Cachan and CNRS UMR 8537, 94235 Cachan Cedex (France); Dal Savio, C.; Karrai, K. [Attocube systems AG, Koeniginstrasse 11A RGB, Munich 80539 (Germany); Dantelle, G. [Laboratoire de Physique de la Matiere Condensee, Ecole Polytechnique and CNRS UMR 7643, 91128 Palaiseau (France); Thiaville, A.; Rohart, S. [Laboratoire de Physique des Solides, Universite Paris-Sud and CNRS UMR 8502, 91405 Orsay (France)

    2012-04-09

    We demonstrate quantitative magnetic field mapping with nanoscale resolution, by applying a lock-in technique on the electron spin resonance frequency of a single nitrogen-vacancy defect placed at the apex of an atomic force microscope tip. In addition, we report an all-optical magnetic imaging technique which is sensitive to large off-axis magnetic fields, thus extending the operation range of diamond-based magnetometry. Both techniques are illustrated by using a magnetic hard disk as a test sample. Owing to the non-perturbing and quantitative nature of the magnetic probe, this work should open up numerous perspectives in nanomagnetism and spintronics.

  10. Note: Commercial SQUID magnetometer-compatible NMR probe and its application for studying a quantum magnet

    Science.gov (United States)

    Vennemann, T.; Jeong, M.; Yoon, D.; Magrez, A.; Berger, H.; Yang, L.; Živković, I.; Babkevich, P.; Rønnow, H. M.

    2018-04-01

    We present a compact nuclear magnetic resonance (NMR) probe which is compatible with a magnet of a commercial superconducting quantum interference device magnetometer and demonstrate its application to the study of a quantum magnet. We employ trimmer chip capacitors to construct an NMR tank circuit for low temperature measurements. Using a magnetic insulator MoOPO4 with S = 1/2 (Mo5+) as an example, we show that the T-dependence of the circuit is weak enough to allow the ligand-ion NMR study of magnetic systems. Our 31P NMR results are compatible with previous bulk susceptibility and neutron scattering experiments and furthermore reveal unconventional spin dynamics.

  11. Magnetic properties of Martian surface material

    Science.gov (United States)

    Hargraves, R. B.

    1984-01-01

    The hypothesis that the magnetic properties of the Martian surface material are due to the production of a magnetic phase in the clay mineral nontronite by transient shock heating is examined. In the course of the investigation a magnetic material is produced with rather unusual properties. Heating from 900 C to 1000 C, of natural samples of nontronite leads first to the production of what appears to be Si doped maghemite gamma (-Fe2O3). Although apparently metastable, the growth of gamma -Fe2O3 at these temprtures is unexpected, and its relative persistence of several hours at 1000 C is most surprising. Continued annealing of this material for longer periods promote the crystallization of alpha Fe2O3 and cristobalite (high temperature polymorph of SiO2). All available data correlate this new magnetic material with the cristobalite hence our naming it magnetic ferri cristobalite. Formation of this magnetic cristobalite, however, may require topotactic growth from a smectite precursor.

  12. Direct measurement of surface-state conductance by microscopic four-point probe method

    DEFF Research Database (Denmark)

    Hasegawa, S.; Shiraki, I.; Tanikawa, T.

    2002-01-01

    For in situ measurements of local electrical conductivity of well defined crystal surfaces in ultrahigh vacuum, we have developed microscopic four-point probes with a probe spacing of several micrometres, installed in a scanning-electron - microscope/electron-diffraction chamber. The probe...

  13. Surface magnetism in iron, cobalt, and nickel

    DEFF Research Database (Denmark)

    Alde´n, M.; Mirbt, S.; Skriver, Hans Lomholt

    1992-01-01

    with experimental values to within 10%, which may be considered most satisfactory in view of the computational efficiency of the Green’s function technique. Exchange and correlation have been treated wihtin the local spin-density approximation and we have considered three different parametrizations of the original......We have calculated magnetic moments, work functions, and surface energies for several of the most closely packed surfaces of iron, cobalt, and nickel by means of a spin-polarized Green’s-function technique based on the linear muffin-tin orbitals method within the tight-binding and atomic sphere...... approximations. We find enhanced spin moments at all the surfaces considered except for Ni fcc(111), where the moment at the surface reverts to its bulk value. This is in close agreement with earlier slab calculations. In addition, we find that the calculated work functions and surface energies agree...

  14. Surface treatment of magnetic recording heads

    Science.gov (United States)

    Komvopoulos, Kyriakos; Brown, Ian G.; Wei, Bo; Anders, Simone; Anders, Andre; Bhatia, Singh C.

    1995-01-01

    Surface modification of magnetic recording heads using plasma immersion ion implantation and deposition is disclosed. This method may be carried out using a vacuum arc deposition system with a metallic or carbon cathode. By operating a plasma gun in a long-pulse mode and biasing the substrate holder with short pulses of a high negative voltage, direct ion implantation, recoil implantation, and surface deposition are combined to modify the near-surface regions of the head or substrate in processing times which may be less than 5 min. The modified regions are atomically mixed into the substrate. This surface modification improves the surface smoothness and hardness and enhances the tribological characteristics under conditions of contact-start-stop and continuous sliding. These results are obtained while maintaining original tolerances.

  15. Development of a fiber based Raman probe compatible with interventional magnetic resonance imaging

    Science.gov (United States)

    Ashok, Praveen C.; Praveen, Bavishna B.; Rube, Martin; Cox, Benjamin; Melzer, Andreas; Dholakia, Kishan

    2014-02-01

    Raman spectroscopy has proven to be a powerful tool for discriminating between normal and abnormal tissue types. Fiber based Raman probes have demonstrated its potential for in vivo disease diagnostics. Combining Raman spectroscopy with Magnetic Resonance Imaging (MRI) opens up new avenues for MR guided minimally invasive optical biopsy. Although Raman probes are commercially available, they are not compatible with a MRI environment due to the metallic components which are used to align the micro-optic components such as filters and lenses at the probe head. Additionally they are not mechanically compatible with a typical surgical environment as factors such as sterility and length of the probe are not addressed in those designs. We have developed an MRI compatible fiber Raman probe with a disposable probe head hence maintaining sterility. The probe head was specially designed to avoid any material that would cause MR imaging artefacts. The probe head that goes into patient's body had a diameter <1.5 mm so that it is compatible with biopsy needles and catheters. The probe has been tested in MR environment and has been proven to be capable of obtaining Raman signal while the probe is under real-time MR guidance.

  16. Analysis of the distribution of magnetic fluid inside tumors by a giant magnetoresistance probe

    KAUST Repository

    Gooneratne, Chinthaka P.

    2013-11-29

    Magnetic fluid hyperthermia (MFH) therapy uses the magnetic component of electromagnetic fields in the radiofrequency spectrum to couple energy to magnetic nanoparticles inside tumors. In MFH therapy, magnetic fluid is injected into tumors and an alternating current (AC) magnetic flux is applied to heat the magnetic fluid- filled tumor. If the temperature can be maintained at the therapeutic threshold of 42C for 30 minutes or more, the tumor cells can be destroyed. Analyzing the distribution of the magnetic fluid injected into tumors prior to the heating step in MFH therapy is an essential criterion for homogenous heating of tumors, since a decision can then be taken on the strength and localization of the applied external AC magnetic flux density needed to destroy the tumor without affecting healthy cells. This paper proposes a methodology for analyzing the distribution of magnetic fluid in a tumor by a specifically designed giant magnetoresistance (GMR) probe prior to MFH heat treatment. Experimental results analyzing the distribution of magnetic fluid suggest that different magnetic fluid weight densities could be estimated inside a single tumor by the GMR probe. 2013 Gooneratne et al.

  17. Analysis of the distribution of magnetic fluid inside tumors by a giant magnetoresistance probe.

    Science.gov (United States)

    Gooneratne, Chinthaka P; Kurnicki, Adam; Yamada, Sotoshi; Mukhopadhyay, Subhas C; Kosel, Jürgen

    2013-01-01

    Magnetic fluid hyperthermia (MFH) therapy uses the magnetic component of electromagnetic fields in the radiofrequency spectrum to couple energy to magnetic nanoparticles inside tumors. In MFH therapy, magnetic fluid is injected into tumors and an alternating current (AC) magnetic flux is applied to heat the magnetic fluid- filled tumor. If the temperature can be maintained at the therapeutic threshold of 42 °C for 30 minutes or more, the tumor cells can be destroyed. Analyzing the distribution of the magnetic fluid injected into tumors prior to the heating step in MFH therapy is an essential criterion for homogenous heating of tumors, since a decision can then be taken on the strength and localization of the applied external AC magnetic flux density needed to destroy the tumor without affecting healthy cells. This paper proposes a methodology for analyzing the distribution of magnetic fluid in a tumor by a specifically designed giant magnetoresistance (GMR) probe prior to MFH heat treatment. Experimental results analyzing the distribution of magnetic fluid suggest that different magnetic fluid weight densities could be estimated inside a single tumor by the GMR probe.

  18. Analysis of the distribution of magnetic fluid inside tumors by a giant magnetoresistance probe.

    Directory of Open Access Journals (Sweden)

    Chinthaka P Gooneratne

    Full Text Available Magnetic fluid hyperthermia (MFH therapy uses the magnetic component of electromagnetic fields in the radiofrequency spectrum to couple energy to magnetic nanoparticles inside tumors. In MFH therapy, magnetic fluid is injected into tumors and an alternating current (AC magnetic flux is applied to heat the magnetic fluid- filled tumor. If the temperature can be maintained at the therapeutic threshold of 42 °C for 30 minutes or more, the tumor cells can be destroyed. Analyzing the distribution of the magnetic fluid injected into tumors prior to the heating step in MFH therapy is an essential criterion for homogenous heating of tumors, since a decision can then be taken on the strength and localization of the applied external AC magnetic flux density needed to destroy the tumor without affecting healthy cells. This paper proposes a methodology for analyzing the distribution of magnetic fluid in a tumor by a specifically designed giant magnetoresistance (GMR probe prior to MFH heat treatment. Experimental results analyzing the distribution of magnetic fluid suggest that different magnetic fluid weight densities could be estimated inside a single tumor by the GMR probe.

  19. Magnetically engineered Cd-free quantum dots as dual-modality probes for fluorescence/magnetic resonance imaging of tumors.

    Science.gov (United States)

    Ding, Ke; Jing, Lihong; Liu, Chunyan; Hou, Yi; Gao, Mingyuan

    2014-02-01

    Magnetically engineered Cd-free CuInS2@ZnS:Mn quantum dots (QDs) were designed, synthesized, and evaluated as potential dual-modality probes for fluorescence and magnetic resonance imaging (MRI) of tumors in vivo. The synthesis of Mn-doped core-shell structured CuInS2@ZnS mainly comprised three steps, i.e., the preparation of fluorescent CuInS2 seeds, the particle surface coating of ZnS, and the Mn-doping of the ZnS shells. Systematic spectroscopy studies were carried out to illustrate the impacts of ZnS coating and the following Mn-doping on the optical properties of the QDs. In combination with conventional fluorescence, fluorescence excitation, and time-resolved fluorescence measurements, the structure of CuInS2@ZnS:Mn QDs prepared under optimized conditions presented a Zn gradient CuInS2 core and a ZnS outer shell, while Mn ions were mainly located in the ZnS shell, which well balanced the optical and magnetic properties of the resultant QDs. For the following in vivo imaging experiments, the hydrophobic CuInS2@ZnS:Mn QDs were transferred into water upon ligand exchange reactions by replacing the 1-dodecanethiol ligand with dihydrolipoic acid-poly(ethylene glycol) (DHLA-PEG) ligand. The MTT assays based on HeLa cells were carried out to evaluate the cytotoxicity of the current Cd-free CuInS2@ZnS:Mn QDs for comparing with that of water soluble CdTe QDs. Further in vivo fluorescence and MR imaging experiments suggested that the PEGylated CuInS2@ZnS:Mn QDs could well target both subcutaneous and intraperitoneal tumors in vivo. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Magnetic surfaces, thin films, and multilayers

    International Nuclear Information System (INIS)

    Parkin, S.S.P.; Renard, J.P.; Shinjo, T.; Zinn, W.

    1992-01-01

    This paper details recent developments in the magnetism of surfaces, thin films and multilayers. More than 20 invited contributions and more than 60 contributed papers attest to the great interest and vitality of this subject. In recent years the study of magnetic surfaces, thin films and multilayers has undergone a renaissance, partly motivated by the development of new growth and characterization techniques, but perhaps more so by the discovery of many exciting new properties, some quite unanticipated. These include, most recently, the discovery of enormous values of magnetoresistance in magnetic multilayers far exceeding those found in magnetic single layer films and the discovery of oscillatory interlayer coupling in transition metal multilayers. These experimental studies have motivated much theoretical work. However these developments are to a large extent powered by materials engineering and our ability to control and understand the growth of thin layers just a few atoms thick. The preparation of single crystal thin film layers and multilayers remains important for many studies, in particular, for properties dependent. These studies obviously require engineering not just a layer thicknesses but of lateral dimensions as well. The properties of such structures are already proving to be a great interest

  1. Three-dimensional sensitivity mapping of a handheld magnetic probe for sentinel lymph node biopsy

    Directory of Open Access Journals (Sweden)

    Akihiro Kuwahata

    2017-05-01

    Full Text Available An experimental apparatus for three-dimensional sensitivity mapping of a handheld magnetic probe with a permanent magnet and a Hall sensor was developed. To optimize the shapes and sizes of the magnets, the sensitivity mappings of two types of magnets, column- and cone-type magnets, were evaluated by the experimental apparatus. The longitudinal sensitivities of column and cone types are 8 and 9 mm, respectively, for 5 μL of magnetic nanoparticles. The measured longitudinal sensitivities agree well with the sensitivities calculated by the finite element method. Furthermore, the maximum lateral resolutions of column and cone types are 4.1 and 3.7 mm, respectively. In terms of the directionality, the sensitivities of column and cone types of the angle of 90° with respect to the probe axis fall approximately to 72% and 50% at 6 mm distance from the probe head, indicating that the cone type has high directionality due to its sharp shape. The measurement of sensitivity mapping revealed that the characteristics of the cone-type magnet are superior to that of the column-type magnet for the identification of sentinel lymph nodes.

  2. Local probing spinel and perovskite complex magnetic systems

    CERN Document Server

    De Pinho Oliveira, Goncalo; Lima Lopes, Armandina Maria

    Materials with multifunctional physical properties are crucial for the modern society, especially those which display a strong coupling between magnetic, lattice and polar degrees of freedom. This by far unexploited capability promises new paradigm-shift technologies for cooling technologies, magnetic data storage, high-frequency magnetic devices, spintronics, and micro-electromechanical systems. Alongside with the understanding of the properties of these materials, the need to improve them and to make them smaller and more efficient is a current goal. Device miniaturization towards very high-density data storage stands also as a trend in modern science and technology. Here, the integration of several functions into one material system has become highly desirable. Research in this area has already highlighted complex magnetic materials with po- tential for multifunctional applications based on spinel type structures like CdMn2O4 or multiferroic CdCr2S4 or even RCrO3 with orthorhombically distorted perovskite ...

  3. Ionization and reflux dependence of magnetic instability generation and probing inside laser-irradiated solid thin foils

    Science.gov (United States)

    Huang, L. G.; Schlenvoigt, H.-P.; Takabe, H.; Cowan, T. E.

    2017-10-01

    When an intense laser accelerated electron beam, with large current density on the order of 1012 A/cm2, enters a solid density plasma, it is well-known to be subject to a number of different types of instabilities that cause it to filament. In this work, we investigate the transport instability of a fast electron beam that is imprinted on the self-generated magnetic filaments inside the solid density plasmas using particle-in-cell simulations. By varying collisional ionization models, our simulations show that the atomic ionization process is crucial to determine the structure of the magnetic filaments. We further attribute the generation of bulk magnetic filaments to Weibel-like instability mechanism caused by counter-propagating hot forward-bulk return current streams and counter-propagating hot forward-reflux current streams. It is found that the magnetic fields in the filament channels near the rear surface are around one order of magnitude higher than those near the front surface of the thin solid target. This asymmetry is likely induced by the very different properties of bulk electron stream and hot reflux electron stream in terms of density and velocity distribution. Finally, we propose to probe the magnetic fields inside the solid density plasmas by X-Ray polarimetry via Faraday rotation using X-Ray free electron lasers (XFELs). The synthetic simulations show that XFELs are capable to detect the magnetic fields from relativistic laser-solid interactions.

  4. Hydrogen as a probe into 5f-magnetism

    Czech Academy of Sciences Publication Activity Database

    Mašková, S.; Havela, L.; Šantavá, Eva; Miliyanchuk, K.

    2009-01-01

    Roč. 100, č. 9 (2009), s. 1187-1189 ISSN 1862-5282 Grant - others:GA ČR(CZ) GA202/07/0418; GA MŠk(CZ) OC 146 Institutional research plan: CEZ:AV0Z10100520 Keywords : uranium compounds * magnetic properties * hydrogen absorption Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 0.862, year: 2009

  5. Probing electric field control of magnetism using ferromagnetic resonance

    Science.gov (United States)

    Zhou, Ziyao; Trassin, Morgan; Gao, Ya; Gao, Yuan; Qiu, Diana; Ashraf, Khalid; Nan, Tianxiang; Yang, Xi; Bowden, S. R.; Pierce, D. T.; Stiles, M. D.; Unguris, J.; Liu, Ming; Howe, Brandon M.; Brown, Gail J.; Salahuddin, S.; Ramesh, R.; Sun, Nian X.

    2015-01-01

    Exchange coupled CoFe/BiFeO3 thin-film heterostructures show great promise for power-efficient electric field-induced 180° magnetization switching. However, the coupling mechanism and precise qualification of the exchange coupling in CoFe/BiFeO3 heterostructures have been elusive. Here we show direct evidence for electric field control of the magnetic state in exchange coupled CoFe/BiFeO3 through electric field-dependent ferromagnetic resonance spectroscopy and nanoscale spatially resolved magnetic imaging. Scanning electron microscopy with polarization analysis images reveal the coupling of the magnetization in the CoFe layer to the canted moment in the BiFeO3 layer. Electric field-dependent ferromagnetic resonance measurements quantify the exchange coupling strength and reveal that the CoFe magnetization is directly and reversibly modulated by the applied electric field through a ~180° switching of the canted moment in BiFeO3. This constitutes an important step towards robust repeatable and non-volatile voltage-induced 180° magnetization switching in thin-film multiferroic heterostructures and tunable RF/microwave devices.

  6. Direct measurement of surface-state conductance by microscopic four-point probe method

    DEFF Research Database (Denmark)

    Hasegawa, S.; Shiraki, I.; Tanikawa, T.

    2002-01-01

    For in situ measurements of local electrical conductivity of well defined crystal surfaces in ultrahigh vacuum, we have developed microscopic four-point probes with a probe spacing of several micrometres, installed in a scanning-electron - microscope/electron-diffraction chamber. The probe...... is precisely positioned on targeted areas of the sample surface by using piezoactuators. This apparatus enables conductivity measurement with extremely high surface sensitivity, resulting in direct access to surface-state conductivity of the surface superstructures, and clarifying the influence of atomic steps...

  7. Detection of secondary phases in duplex stainless steel by magnetic force microscopy and scanning Kelvin probe force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ramírez-Salgado, J. [Instituto Mexicano del Petróleo, Dirección de Investigación y Posgrado, Eje Central Norte Lázaro Cárdenas, No. 152, 07730 D.F., México (Mexico); Domínguez-Aguilar, M.A., E-mail: madoming@imp.mx [Instituto Mexicano del Petróleo, Dirección de Investigación y Posgrado, Eje Central Norte Lázaro Cárdenas, No. 152, 07730 D.F., México (Mexico); Castro-Domínguez, B. [University of Tokyo, Department of Chemical System Engineering, Faculty of Engineering Bldg. 5, 7F 722, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113–8656 (Japan); Hernández-Hernández, P. [Instituto Mexicano del Petróleo, Dirección de Investigación y Posgrado, Eje Central Norte Lázaro Cárdenas, No. 152, 07730 D.F., México (Mexico); Newman, R.C. [University of Toronto, Department of Chemical Engineering and Applied Chemistry, 200 College Street, Toronto M5S 3E5 (Canada)

    2013-12-15

    The secondary phase transformations in a commercial super duplex stainless steel were investigated by micro-chemical analyses and high resolution scanning probe microscopy. Energy dispersive X-ray and electron probe detected ferrite and austenite as well as secondary phases in unetched aged duplex stainless steel type 25Cr-7Ni-3Mo. Volta potential indicated that nitride and sigma appeared more active than ferrite, while secondary austenite and austenite presented a nobler potential. Reversal order in nobility is thought to be attributable to the potential ranking provided by oxide nature diversity as a result of secondary phase surface compositions on steel. After eutectoid transformation, secondary austenite was detected by electron probe microanalysis, whereas atomic force microscopy distinguished this phase from former austenite by image contrast. Magnetic force microscopy revealed a “ghosted” effect on the latter microstructure probably derived from metal memory reminiscence of mechanical polishing at passivity and long range magnetic forces of ferrite phase. - Highlights: • Nobility detection of secondary phases by SKPFM in DSS particles is not a straightforward procedure. • As Volta potential and contrast are not always consistent SKPFM surface oxides is thought played an important role in detection. • AFM distinguished secondary austenite from former austenite by image contrast though SEM required EPMA.

  8. Establishment of a novel immunoassay system for rapid detection of 2,4-dichlorophenoxyacetic acid residues based on magnetic-fluorescent probes

    Directory of Open Access Journals (Sweden)

    WANG Yuanfeng

    2014-12-01

    Full Text Available A novel immunoassay system based on magnetic-fluorescent probes was established to detect 2.4-dichlorophenoxyacetic acid (2,4-D residue in liquid system in food and agricultural products.The composites of anti-2,4-D antibody bound to Fe3O4@SiO2-NH2 was employed as the solid phase as well as magnetic probe.The composites composed of 2,4-D-OVA labeled with CdTe@SiO2-NH2 as the fluorescent probe was used to produce fluorescent signal.2,4-D and its fluorescent probe competed binding the antibody on the surface of the magnetic probe.The optimization of 2,4-D-OVA dosage,coupling PH and reaction time in preparing the fluorescent probe were investigated.It showed that in the synthesis of fluorescent probe 8.2 was the optimal pH,70 min was the optimal coupling time,500 μL amount of 2,4-D-OVA.The standard curve was obtained with the concentration of 2,4-D and the maximum fluorescence intensity.The detection limit of the assay was gotten and it was 3.55×10-8.One reaction step and one washing step were needed.The assay significantly shortened the testing time and amplified the detection signal compared with classic ELISA.

  9. Design and Application of Hybrid Magnetic Field-Eddy Current Probe

    Science.gov (United States)

    Wincheski, Buzz; Wallace, Terryl; Newman, Andy; Leser, Paul; Simpson, John

    2013-01-01

    The incorporation of magnetic field sensors into eddy current probes can result in novel probe designs with unique performance characteristics. One such example is a recently developed electromagnetic probe consisting of a two-channel magnetoresistive sensor with an embedded single-strand eddy current inducer. Magnetic flux leakage maps of ferrous materials are generated from the DC sensor response while high-resolution eddy current imaging is simultaneously performed at frequencies up to 5 megahertz. In this work the design and optimization of this probe will be presented, along with an application toward analysis of sensory materials with embedded ferromagnetic shape-memory alloy (FSMA) particles. The sensory material is designed to produce a paramagnetic to ferromagnetic transition in the FSMA particles under strain. Mapping of the stray magnetic field and eddy current response of the sample with the hybrid probe can thereby image locations in the structure which have experienced an overstrain condition. Numerical modeling of the probe response is performed with good agreement with experimental results.

  10. Soft-landing ion deposition of isolated radioactive probe atoms on surfaces: A novel method

    NARCIS (Netherlands)

    Laurens, C.R; Rosu, M.F; Pleiter, F; Niesen, L

    1997-01-01

    We present a method to deposit a wide range of radioactive probe atoms on surfaces, without introducing lattice damage or contaminating the surface with other elements or isotopes. In this method, the probe atoms are mass separated using an isotope separator, decelerated to 5 eV, and directly

  11. Detection of the position and cross-section of a tokamak plasma with magnetic probes

    International Nuclear Information System (INIS)

    Aikawa, Hiroshi; Ogata, Atsushi; Suzuki, Yasuo

    1977-02-01

    The position and cross-sectional shape of a Tokamak plasma are obtained analytically from magnetic probe signals, taking into consideration the toroidal effect. Multipole moment analysis of the plasma current density, introducing the vertical asymmetry, shows the horizontal and vertical displacements and the elliptical deviation. The error in the measurement is estimated by means of the least square method. The observed error is proportional to the error of setting the probes, and inversely proportional to the square root of the number of probes. (auth.)

  12. Electrical conduction through surface superstructures measured by microscopic four-point probes

    DEFF Research Database (Denmark)

    Hasegawa, S.; Shiraki, I.; Tanabe, F.

    2003-01-01

    For in-situ measurements of the local electrical conductivity of well-defined crystal surfaces in ultra-high vacuum, we have developed two kinds of microscopic four-point probe methods. One involves a "four-tip STM prober," in which four independently driven tips of a scanning tunneling microscope...... (STM) are used for measurements of four-point probe conductivity. The probe spacing can be changed from 500 nm to 1 mm. The other method involves monolithic micro-four-point probes, fabricated on silicon chips, whose probe spacing is fixed around several mum. These probes are installed in scanning...... compared with the macroscopic four-point probe method. Then the conduction through the topmost atomic layers (surface-state conductivity) and the influence of atomic steps on conductivity can be directly measured....

  13. Estimation of current sheath curvature in plasma focus device using magnetic probes

    International Nuclear Information System (INIS)

    Li, Cai; Yujuan, Shi; Patran, A.; Rawat, R.S.

    2002-01-01

    The dynamics of current sheath, in terms of its speed and sheath curvature, in dense plasma focus device was investigated in its axial acceleration phase using multiple magnetic probes. The investigation was performed for different filling gas pressures of neon. The relative X-ray yields were estimated using a diode X-ray spectrometer. A possible correlation between the current sheath curvature and the X-ray emission was explored. The investigation demonstrates the effective use of relatively simple diagnostics tool, the magnetic probes, in the estimation of current sheath axial speeds and curvatures. (authors)

  14. A versatile rotary-stage high frequency probe station for studying magnetic films and devices

    Energy Technology Data Exchange (ETDEWEB)

    He, Shikun [Data Storage Institute, A*STAR (Agency for Science, Technology and Research), 2 Fusionopolis Way, #08-01, Innovis 138634 (Singapore); Division of Physics and Applied Physics, School of Physical and Mathematical Sciences, Nanyang Technological University, Singapore 637371 (Singapore); Meng, Zhaoliang; Huang, Lisen; Yap, Lee Koon; Zhou, Tiejun [Data Storage Institute, A*STAR (Agency for Science, Technology and Research), 2 Fusionopolis Way, #08-01, Innovis 138634 (Singapore); Panagopoulos, Christos [Division of Physics and Applied Physics, School of Physical and Mathematical Sciences, Nanyang Technological University, Singapore 637371 (Singapore)

    2016-07-15

    We present a rotary-stage microwave probe station suitable for magnetic films and spintronic devices. Two stages, one for field rotation from parallel to perpendicular to the sample plane (out-of-plane) and the other intended for field rotation within the sample plane (in-plane) have been designed. The sample probes and micro-positioners are rotated simultaneously with the stages, which allows the field orientation to cover θ from 0{sup ∘} to 90{sup ∘} and φ from 0{sup ∘} to 360{sup ∘}. θ and φ being the angle between the direction of current flow and field in a out-of-plane and an in-plane rotation, respectively. The operation frequency is up to 40 GHz and the magnetic field up to 1 T. The sample holder vision system and probe assembly are compactly designed for the probes to land on a wafer with diameter up to 3 cm. Using homemade multi-pin probes and commercially available high frequency probes, several applications including 4-probe DC measurements, the determination of domain wall velocity, and spin transfer torque ferromagnetic resonance are demonstrated.

  15. Individually grown cobalt nanowires as magnetic force microscopy probes.

    Science.gov (United States)

    Alotaibi, Shuaa; Samba, Joshua; Pokharel, Sabin; Lan, Yucheng; Uradu, Kelechi; Afolabi, Ayodeji; Unlu, Ilyas; Basnet, Gobind; Aslan, Kadir; Flanders, Bret N; Lisfi, Abdellah; Ozturk, Birol

    2018-02-26

    AC electric fields were utilized in the growth of individual high-aspect ratio cobalt nanowires from simple salt solutions using the Directed Electrochemical Nanowire Assembly method. Nanowire diameters were tuned from the submicron scale to 40 nm by adjusting the AC voltage frequency and the growth solution concentration. The structural properties of the nanowires, including shape and crystallinity, were identified using electron microscopy. Hysteresis loops obtained along different directions of an individual nanowire using vibrating sample magnetometry showed that the magnetocrystalline anisotropy energy has the same order of magnitude as the shape anisotropy energy. Additionally, the saturation magnetization of an individual cobalt nanowire was estimated to be close to the bulk single crystal value. A small cobalt nanowire segment was grown from a conductive atomic force microscope cantilever tip that was utilized in magnetic force microscopy (MFM) imaging. The fabricated MFM tip provided moderate quality magnetic images of an iron-cobalt thin-film sample.

  16. Probing magnetic fields with Square Kilometre array and its precursors

    Indian Academy of Sciences (India)

    48

    2016-11-16

    Nov 16, 2016 ... redshift will provide important information on magnetic field evolution as a function of redshift. The background ... determines the typical masses of stars and the initial mass function, regulating the propagation and confinement of ..... Since cosmic ray spectrum in the Galaxy is known (Ackermann et al., 2012) ...

  17. Probing magnetic fields with Square Kilometre array and its precursors

    Indian Academy of Sciences (India)

    48

    2016-11-16

    Nov 16, 2016 ... find measurable Faraday rotation towards only ∼1 source per square degree with an integration ..... of these jets and the role of magnetic fields in their production is ill understood (Ray, 2009). One expects .... (2015a), the theoretical estimate is much smaller than the measured values and this type of field.

  18. Carbon induced magnetism of SnO2 surfaces

    International Nuclear Information System (INIS)

    Lu, Ying-Bo; Ling, Z.C.; Cong, Wei-Yan; Zhang, Peng; Dai, Ying

    2015-01-01

    The magnetism induced by Carbon (C) in SnO 2 surfaces are investigated by first principle calculations. The results show that C substitution at the outmost surface oxygen sites can induce magnetism in (110), (001) and (101) surfaces of SnO 2 . (110) surface is the most stable surface and the magnetism in which is stronger than that in other two surfaces, indicating that it is (110), but not other surfaces provides the main contribution to the surface magnetism of C-doped SnO 2 (SnO 2 :C). The magnetic moments predominantly come from C-2p orbitals, which arise from the crystal field transformation induced by the loss of coordinated atoms and the destroy of the local symmetry, and is enhanced by the local lattice distortion due to the Jahn–Teller effect. In all three surface slabs, the magnetism decays when C dopants are deeper from the outmost surfaces and disappears eventually. This work provides more rational understanding to the observed magnetism in SnO 2 :C materials than ever. - Highlights: • We investigate surface magnetism in (110), (001) and (101) surfaces of SnO 2 :C. • (110) surface provides the main contribution to the surface magnetism of SnO 2 :C. • Magnetism predominantly come from C-2p orbitals and crystal field transformation

  19. THE MAGNETIC FIELD IN TAURUS PROBED BY INFRARED POLARIZATION

    International Nuclear Information System (INIS)

    Chapman, Nicholas L.; Goldsmith, Paul F.; Pineda, Jorge L.; Li Di; Clemens, D. P.; Krco, Marko

    2011-01-01

    We present maps of the plane-of-sky magnetic field within two regions of the Taurus molecular cloud: one in the dense core L1495/B213 filament and the other in a diffuse region to the west. The field is measured from the polarization of background starlight seen through the cloud. In total, we measured 287 high-quality near-infrared polarization vectors in these regions. In L1495/B213, the percent polarization increases with column density up to A V ∼ 9 mag, the limits of our data. The radiative torques model for grain alignment can explain this behavior, but models that invoke turbulence are inconsistent with the data. We also combine our data with published optical and near-infrared polarization measurements in Taurus. Using this large sample, we estimate the strength of the plane-of-sky component of the magnetic field in nine subregions. This estimation is done with two different techniques that use the observed dispersion in polarization angles. Our values range from 5 to 82 μG and tend to be higher in denser regions. In all subregions, the critical index of the mass-to-magnetic flux ratio is sub-unity, implying that Taurus is magnetically supported on large scales (∼2 pc). Within the region observed, the B213 filament takes a sharp turn to the north and the direction of the magnetic field also takes a sharp turn, switching from being perpendicular to the filament to becoming parallel. This behavior can be understood if we are observing the rim of a bubble. We argue that it has resulted from a supernova remnant associated with a recently discovered nearby gamma-ray pulsar.

  20. Magnification bias as a novel probe for primordial magnetic fields

    International Nuclear Information System (INIS)

    Camera, S.; Fedeli, C.; Moscardini, L.

    2014-01-01

    In this paper we investigate magnetic fields generated in the early Universe. These fields are important candidates at explaining the origin of astrophysical magnetism observed in galaxies and galaxy clusters, whose genesis is still by and large unclear. Compared to the standard inflationary power spectrum, intermediate to small scales would experience further substantial matter clustering, were a cosmological magnetic field present prior to recombination. As a consequence, the bias and redshift distribution of galaxies would also be modified. Hitherto, primordial magnetic fields (PMFs) have been tested and constrained with a number of cosmological observables, e.g. the cosmic microwave background radiation, galaxy clustering and, more recently, weak gravitational lensing. Here, we explore the constraining potential of the density fluctuation bias induced by gravitational lensing magnification onto the galaxy-galaxy angular power spectrum. Such an effect is known as magnification bias. Compared to the usual galaxy clustering approach, magnification bias helps in lifting the pathological degeneracy present amongst power spectrum normalisation and galaxy bias. This is because magnification bias cross-correlates galaxy number density fluctuations of nearby objects with weak lensing distortions of high-redshift sources. Thus, it takes advantage of the gravitational deflection of light, which is insensitive to galaxy bias but powerful in constraining the density fluctuation amplitude. To scrutinise the potentiality of this method, we adopt a deep and wide-field spectroscopic galaxy survey. We show that magnification bias does contain important information on primordial magnetism, which will be useful in combination with galaxy clustering and shear. We find we shall be able to rule out at 95.4% CL amplitudes of PMFs larger than 5 × 10 −4 nG for values of the PMF power spectral index n B ∼ 0

  1. Dual imaging probes for magnetic resonance imaging and fluorescence microscopy based on perovskite manganite nanoparticles

    Czech Academy of Sciences Publication Activity Database

    Kačenka, M.; Kaman, Ondřej; Kotek, J.; Falteisek, L.; Černý, J.; Jirák, D.; Herynek, V.; Zacharovová, K.; Berková, A.; Jendelová, Pavla; Kupčík, Jaroslav; Pollert, Emil; Veverka, Pavel; Lukeš, I.

    2011-01-01

    Roč. 21, č. 1 (2011), s. 157-164 ISSN 0959-9428 R&D Projects: GA AV ČR KAN200200651 Institutional research plan: CEZ:AV0Z10100521; CEZ:AV0Z50390703; CEZ:AV0Z40720504 Keywords : cellular labelling * dual probe * magnetic nanoparticles * MRI * silica coating Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 5.968, year: 2011

  2. Robotized Surface Mounting of Permanent Magnets

    Directory of Open Access Journals (Sweden)

    Erik Hultman

    2014-10-01

    Full Text Available Using permanent magnets on a rotor can both simplify the design and increase the efficiency of electric machines compared to using electromagnets. A drawback, however, is the lack of existing automated assembly methods for large machines. This paper presents and motivates a method for robotized surface mounting of permanent magnets on electric machine rotors. The translator of the Uppsala University Wave Energy Converter generator is used as an example of a rotor. The robot cell layout, equipment design and assembly process are presented and validated through computer simulations and experiments with prototype equipment. A comparison with manual assembly indicates substantial cost savings and an improved work environment. By using the flexibility of industrial robots and a scalable equipment design, it is possible for this assembly method to be adjusted for other rotor geometries and sizes. Finally, there is a discussion on the work that remains to be done on improving and integrating the robot cell into a production line.

  3. Renormalization and the breakup of magnetic surfaces

    International Nuclear Information System (INIS)

    Greene, J.M.

    1983-02-01

    There has been very considerable progress in the last few years on problems that are equivalent to finding the global structure of magnetic field lines in toroidal systems. A general problem of this class has a solution that is so complicated that it is impossible to find equations for the location of a field line which are valid everywhere along an infinitely long line. However, recent results are making it possible to find the asymptotic behavior of such systems in the limit of long lengths. This is just the information that is desired in many situations, since it includes the determination of the existence, or nonexistence, of magnetic surfaces. The key to our present understanding is renormalization. The present state-of-the-art has been described in Robert MacKay's thesis, for which this is an advertisement

  4. Formulation of novel lipid-coated magnetic nanoparticles as the probe for in vivo imaging

    Directory of Open Access Journals (Sweden)

    Mou Chung-Yuan

    2009-09-01

    Full Text Available Abstract Background Application of superparamagnetic iron oxide nanoparticles (SPIOs as the contrast agent has improved the quality of magnetic resonance (MR imaging. Low efficiency of loading the commercially available iron oxide nanoparticles into cells and the cytotoxicity of previously formulated complexes limit their usage as the image probe. Here, we formulated new cationic lipid nanoparticles containing SPIOs feasible for in vivo imaging. Methods Hydrophobic SPIOs were incorporated into cationic lipid 1,2-dioleoyl-3-(trimethylammonium propane (DOTAP and polyethylene-glycol-2000-1,2-distearyl-3-sn-phosphatidylethanolamine (PEG-DSPE based micelles by self-assembly procedure to form lipid-coated SPIOs (L-SPIOs. Trace amount of Rhodamine-dioleoyl-phosphatidylethanolamine (Rhodamine-DOPE was added as a fluorescent indicator. Particle size and zeta potential of L-SPIOs were determined by Dynamic Light Scattering (DLS and Laser Doppler Velocimetry (LDV, respectively. HeLa, PC-3 and Neuro-2a cells were tested for loading efficiency and cytotoxicity of L-SPIOs using fluorescent microscopy, Prussian blue staining and flow cytometry. L-SPIO-loaded CT-26 cells were tested for in vivo MR imaging. Results The novel formulation generates L-SPIOs particle with the average size of 46 nm. We showed efficient cellular uptake of these L-SPIOs with cationic surface charge into HeLa, PC-3 and Neuro-2a cells. The L-SPIO-loaded cells exhibited similar growth potential as compared to unloaded cells, and could be sorted by a magnet stand over ten-day duration. Furthermore, when SPIO-loaded CT-26 tumor cells were injected into Balb/c mice, the growth status of these tumor cells could be monitored using optical and MR images. Conclusion We have developed a novel cationic lipid-based nanoparticle of SPIOs with high loading efficiency, low cytotoxicity and long-term imaging signals. The results suggested these newly formulated non-toxic lipid-coated magnetic

  5. AFM fluid delivery/liquid extraction surface sampling/electrostatic spray cantilever probe

    Science.gov (United States)

    Van Berkel, Gary J.

    2015-06-23

    An electrospray system comprises a liquid extraction surface sampling probe. The probe comprises a probe body having a liquid inlet and a liquid outlet, and having a liquid extraction tip. A solvent delivery conduit is provided for receiving solvent liquid from the liquid inlet and delivering the solvent liquid to the liquid extraction tip. An open liquid extraction channel extends across an exterior surface of the probe body from the liquid extraction tip to the liquid outlet. An electrospray emitter tip is in liquid communication with the liquid outlet of the liquid extraction surface sampling probe. A system for analyzing samples, a liquid junction surface sampling system, and a method of analyzing samples are also disclosed.

  6. Probing large-scale magnetism with the cosmic microwave background

    Science.gov (United States)

    Giovannini, Massimo

    2018-04-01

    Prior to photon decoupling magnetic random fields of comoving intensity in the nano-Gauss range distort the temperature and the polarization anisotropies of the microwave background, potentially induce a peculiar B-mode power spectrum and may even generate a frequency-dependent circularly polarized V-mode. We critically analyze the theoretical foundations and the recent achievements of an interesting trialogue involving plasma physics, general relativity and astrophysics.

  7. Field emission to control tip-sample distance in magnetic probe recording

    NARCIS (Netherlands)

    le Fèbre, A.J.; Lüttge, Regina; Abelmann, Leon; Lodder, J.C.

    2007-01-01

    An integrated method using field-emission to control the tip-sample distance for non-contact magnetic probe recording is presented, adopting the exponential relation between current and electric field as feedback. I/V characteristics that correspond well to field emission theory are measured using a

  8. Electron ring diagnostics with magnetic probes during roll-out and acceleration

    International Nuclear Information System (INIS)

    Schumacher, U.; Ulrich, M.

    1976-03-01

    Different methods using magnetic field probes to determine the properties of electron rings during their compression, roll-out and acceleration are presented. The results of the measurements of the electron number and the axial velocity and acceleration of the rings, as obtained with the various diagnostic devices, are discussed and compared. (orig.) [de

  9. Probing momentum distributions in magnetic tunnel junctions via hot-electron decay

    NARCIS (Netherlands)

    Jansen, R.; Banerjee, T.; Park, B.G.; Lodder, J.C.

    2007-01-01

    The tunnel momentum distribution in a (magnetic) tunnel junction is probed by analyzing the decay of the hot electrons in the Co metal anode after tunneling, using a three-terminal transistor structure in which the hot-electron attenuation is sensitive to the tunnel momentum distribution. Solid

  10. Zeeman effect in sulfur monoxide: a tool to probe magnetic fields in star forming regions

    DEFF Research Database (Denmark)

    Cazzoli, Gabriele; Lattanzi, Valerio; Coriani, Sonia

    2017-01-01

    abundant species in star forming regions, for probing the intensity of magnetic fields via the Zeeman effect. Methods. We investigated the Zeeman effect for several rotational transitions of SO in the (sub-)mm spectral regions by using a frequency-modulated, computer-controlled spectrometer...

  11. Magnetic signature of surface defects at nanodiamonds

    Energy Technology Data Exchange (ETDEWEB)

    Vollmers, Nora Jenny; Gerstmann, Uwe; Schmidt, Wolf Gero [Theoretische Physik, Universitaet Paderborn (Germany)

    2011-07-01

    The n-type doping of diamond has been a long-standing issue, which recently gained attention in the context of nanodiamonds. Attempts of doping with nitrogen failed to result in the Electron paramagnetic Resonance (EPR) fingerprints expected from bulk material. Instead, the nanodiamond signals show a much larger deviation from the free-electron g-value and are believed to be related to intrinsic, carbon inherited defects. However, the absence of the bulk-like EPR spectra does not mean that nitrogen is not incorporated at all. The N atoms could be built in predominantly at or at least close to the surfaces yielding EPR spectra, very different from those measured in the bulk. In this work, we elucidate the situation by investigating the magnetic signature of paramagnetic defects in the nanodiamonds. We use the gauge-including projector augmented plane wave (GI-PAW) approach to calculate the hyperfine splittings and the elements of the electronic g-tensor. Taking the C(100) surface as a first model system, a possible contribution of nitrogen is discussed by comparing EPR parameters for different N incorporation depths: Incorporated directly at the surface, N gives rise to surface states similar to intrinsic carbon dangling bond-like states. Otherwise N is able to introduce surface conductivity as demonstrated by calculated effective mass tensors.

  12. Consideration of magnetic field fluctuation measurements in a torus plasma with heavy ion beam probe

    International Nuclear Information System (INIS)

    Shimizu, A.; Fujisawa, A.; Ohshima, S.; Nakano, H.

    2004-03-01

    The article discusses feasibility of magnetic fluctuation measurement with a heavy ion beam probe (HIBP) in an axisymmetric torus configuration. In the measurements, path integral fluctuation along the probing beam orbit should be considered as is similar to the density fluctuation measurements with HIBP. A calculation, based on an analytic formula, is performed to estimate the path integral effects for fluctuation patterns that have difference in profile, the correlation length, the radial wavelength, and the poloidal mode number. In addition, the large distance between the plasma and the detector is considered to lessen the path integral effect. As a result, it is found that local fluctuation of magnetic field can be properly detected with a heavy ion beam probe. (author)

  13. Waves on the surface of a magnetic fluid layer in a traveling magnetic field

    International Nuclear Information System (INIS)

    Zimmermann, K.; Zeidis, I.; Naletova, V.A.; Turkov, V.A.

    2004-01-01

    The plane flow of a layer of incompressible viscous magnetic fluid with constant magnetic permeability under the action of a traveling magnetic field is analyzed. The strength of the magnetic field producing a sinusoidal traveling small-amplitude wave on the surface of a magnetic fluid is found. This flow can be used in designing mobile robots

  14. X-Ray Detected Magnetic Resonance: A Unique Probe of the Precession Dynamics of Orbital Magnetization Components

    Directory of Open Access Journals (Sweden)

    Roger Guilard

    2011-12-01

    Full Text Available X-ray Detected Magnetic Resonance (XDMR is a novel spectroscopy in which X-ray Magnetic Circular Dichroism (XMCD is used to probe the resonant precession of local magnetization components in a strong microwave pump field. We review the conceptual bases of XDMR and recast them in the general framework of the linear and nonlinear theories of ferromagnetic resonance (FMR. Emphasis is laid on the information content of XDMR spectra which offer a unique opportunity to disentangle the precession dynamics of spin and orbital magnetization components at given absorbing sites. For the sake of illustration, we focus on selected examples in which marked differences were found between FMR and XDMR spectra simultaneously recorded on ferrimagnetically ordered iron garnets. With pumping capabilities extended up to sub-THz frequencies, high-field XDMR should allow us to probe the precession of orbital magnetization components in paramagnetic organometallic complexes with large zero-field splitting. Even more challenging, we suggest that XDMR spectra might be recorded on selected antiferromagnetic crystals for which orbital magnetism is most often ignored in the absence of any supporting experimental evidence.

  15. Design and construction of high-frequency magnetic probe system on the HL-2A tokamak

    Science.gov (United States)

    Liang, S. Y.; Ji, X. Q.; Sun, T. F.; Xu, Yuan; Lu, J.; Yuan, B. S.; Ren, L. L.; Yang, Q. W.

    2017-12-01

    A high-frequency magnetic probe system is designed, calibrated and constructed on the HL-2A tokamak. To investigate the factors which affect the probe frequency response, the inductance and capacitance in the probe system are analyzed using an equivalent circuit. Suitable sizes and turn number of the coil, and the length of transmission cable are optimized based on the theory and detailed test in the calibration. To deal with the frequency response limitation and bake-out, the ceramic grooved technique is used and the probe is wound with a bare copper wire. A cascade filter is manufactured with a suitable bandwidth as well as a good phase consistency between channels. The system has been used in the experiment to measure high frequency (≤300 kHz) magnetohydrodynamic fluctuations, which can meet the requirement of physical analysis on HL-2A.

  16. ZEEMANS - a new facility to probe matter at high magnetic field through neutron scattering

    International Nuclear Information System (INIS)

    Savici, A T; Granroth, G E; Broholm, C; Lee, Y S; Bird, M D

    2010-01-01

    We describe ZEEMANS, a new instrument proposed for the Spallation Neutron Source (SNS) to probe matter at extremely high magnetic fields. The complexity of the high field magnet demands a versatile neutron scattering instrument, capable of performing diffraction (powder and single crystal), SANS, reflectometry, and inelastic spectrometry, with minimal modifications between configurations. In this paper we present a conceptual design for neutron scattering instrumentation to be built around the horizontal conical high field magnet. Monte Carlo simulations and analytical calculations indicate performance on a par with other SNS instrumentation despite limited access to the sample.

  17. Determination of toroidal equilibrium parameters from magnetic probe measurements

    International Nuclear Information System (INIS)

    Brynolf, J.; Eriksson, H.G.; Persson, H.; Hellblom, G.

    1992-12-01

    A method has been developed by which the poloidal flux function in the vacuum region between the plasma and the external conductors (and the iron core) can be deduced from external magnetic field measurements. The plasma is in equilibrium and the solution is restricted to plasmas without irregularities. The poloidal field components Bθ and B r are measured at different poloidal positions outside the liner and modelled by truncated Fourier series. The Grad-Shafranov equation in the vacuum region is then solved with these modelled values of Bθ and B r as boundary conditions. (authors)

  18. Microfour-point probe for studying electronic transport through surface states

    DEFF Research Database (Denmark)

    Petersen, Christian Leth; Grey, Francois; Shiraki, I.

    2000-01-01

    Microfour-point probes integrated on silicon chips have been fabricated with probe spacings in the range 4-60 mum. They provide a simple robust device for electrical transport measurements at surfaces, bridging the gap between conventional macroscopic four-point probes and scanning tunneling...... microscopy. Measurements on Si(111) surfaces in ultrahigh vacuum reveal that the Si(111)-root 3x root3-Ag structure induced by a monolayer of Ag atoms has a four-point resistance two orders of magnitude lower than that of the Si(111)-7x7 clean surface. We attribute this remarkable difference to direct...

  19. Magnetic scanning gate microscopy of a domain wall nanosensor using microparticle probe

    Energy Technology Data Exchange (ETDEWEB)

    Corte-León, H., E-mail: hector.corte@npl.co.uk [National Physical Laboratory, Teddington TW11 0LW (United Kingdom); Royal Holloway University of London, Egham TW20 0EX (United Kingdom); Gribkov, B. [National Physical Laboratory, Teddington TW11 0LW (United Kingdom); Krzysteczko, P. [Physikalisch-Technische Bundesanstalt, Braunschweig D-38116 (Germany); Marchi, F.; Motte, J.-F. [University of Grenoble Alpes, Inst. NEEL, Grenoble F-38042 (France); CNRS, Inst. NEEL, Grenoble F-38042 (France); Schumacher, H.W. [Physikalisch-Technische Bundesanstalt, Braunschweig D-38116 (Germany); Antonov, V. [Royal Holloway University of London, Egham TW20 0EX (United Kingdom); Kazakova, O. [National Physical Laboratory, Teddington TW11 0LW (United Kingdom)

    2016-02-15

    We apply the magnetic scanning gate microscopy (SGM) technique to study the interaction between a magnetic bead (MB) and a domain wall (DW) trapped in an L-shaped magnetic nanostructure. Magnetic SGM is performed using a custom-made probe, comprising a hard magnetic NdFeB bead of diameter 1.6 µm attached to a standard silicon tip. The MB–DW interaction is detected by measuring changes in the electrical resistance of the device as a function of the tip position. By scanning at different heights, we create a 3D map of the MB–DW interaction and extract the sensing volume for different widths of the nanostructure's arms. It is shown that for 50 nm wide devices the sensing volume is a cone of 880 nm in diameter by 1.4 µm in height, and reduces down to 800 nm in height for 100 nm devices with almost no change in its diameter. - Highlights: • AFM tips with a magnetic bead attached used to test interaction with domain wall. • Domain wall inside a nanostructure affect the electrical resistance. • Recording electrical resistance while scanning with modified AFM probe. • Change of resistance as a function of the position of the magnetic bead. • This allows comparing different devices in a reproducible and controllable way.

  20. Heavy ion beam probe plasma diagnostic system for the deep magnetic well LITE device

    International Nuclear Information System (INIS)

    Stufflebeam, J.H.; Jennings, W.C.; Hickok, R.L.

    1978-01-01

    A heavy ion beam probe plasma diagnostic system has been developed for the Laser Initiated Target Experiment (LITE) at UTRC. This is the first application of ion beam probing to a plasma confined by a strongly three dimensional magnetic field. The deep magnetic well, minimum-B field produced by the ''baseball'' magnet coil results in complex trajectories and severe defocusing of both the injected primary beam and detected secondary beam. Spatial resolution can be maintained by aperturing the entrance slit to the detector or installing compensating ion optics. The system is capable of space and time resolved measurements of plastic density and space potential near the central region of the mirror-confined plasma. 11 refs

  1. Vibrational Surface Electron-Energy-Loss Spectroscopy Probes Confined Surface-Phonon Modes

    Directory of Open Access Journals (Sweden)

    Hugo Lourenço-Martins

    2017-12-01

    Full Text Available Recently, two reports [Krivanek et al. Nature (London 514, 209 (2014NATUAS0028-083610.1038/nature13870, Lagos et al. Nature (London 543, 529 (2017NATUAS0028-083610.1038/nature21699] have demonstrated the amazing possibility to probe vibrational excitations from nanoparticles with a spatial resolution much smaller than the corresponding free-space phonon wavelength using electron-energy-loss spectroscopy (EELS. While Lagos et al. evidenced a strong spatial and spectral modulation of the EELS signal over a nanoparticle, Krivanek et al. did not. Here, we show that discrepancies among different EELS experiments as well as their relation to optical near- and far-field optical experiments [Dai et al. Science 343, 1125 (2014SCIEAS0036-807510.1126/science.1246833] can be understood by introducing the concept of confined bright and dark surface phonon modes, whose density of states is probed by EELS. Such a concise formalism is the vibrational counterpart of the broadly used formalism for localized surface plasmons [Ouyang and Isaacson Philos. Mag. B 60, 481 (1989PMABDJ1364-281210.1080/13642818908205921, García de Abajo and Aizpurua Phys. Rev. B 56, 15873 (1997PRBMDO0163-182910.1103/PhysRevB.56.15873, García de Abajo and Kociak Phys. Rev. Lett. 100, 106804 (2008PRLTAO0031-900710.1103/PhysRevLett.100.106804, Boudarham and Kociak Phys. Rev. B 85, 245447 (2012PRBMDO1098-012110.1103/PhysRevB.85.245447]; it makes it straightforward to predict or interpret phenomena already known for localized surface plasmons such as environment-related energy shifts or the possibility of 3D mapping of the related surface charge densities [Collins et al. ACS Photonics 2, 1628 (2015APCHD52330-402210.1021/acsphotonics.5b00421].

  2. Vibrational Surface Electron-Energy-Loss Spectroscopy Probes Confined Surface-Phonon Modes

    Science.gov (United States)

    Lourenço-Martins, Hugo; Kociak, Mathieu

    2017-10-01

    Recently, two reports [Krivanek et al. Nature (London) 514, 209 (2014), 10.1038/nature13870, Lagos et al. Nature (London) 543, 529 (2017), 10.1038/nature21699] have demonstrated the amazing possibility to probe vibrational excitations from nanoparticles with a spatial resolution much smaller than the corresponding free-space phonon wavelength using electron-energy-loss spectroscopy (EELS). While Lagos et al. evidenced a strong spatial and spectral modulation of the EELS signal over a nanoparticle, Krivanek et al. did not. Here, we show that discrepancies among different EELS experiments as well as their relation to optical near- and far-field optical experiments [Dai et al. Science 343, 1125 (2014), 10.1126/science.1246833] can be understood by introducing the concept of confined bright and dark surface phonon modes, whose density of states is probed by EELS. Such a concise formalism is the vibrational counterpart of the broadly used formalism for localized surface plasmons [Ouyang and Isaacson Philos. Mag. B 60, 481 (1989), 10.1080/13642818908205921, García de Abajo and Aizpurua Phys. Rev. B 56, 15873 (1997), 10.1103/PhysRevB.56.15873, García de Abajo and Kociak Phys. Rev. Lett. 100, 106804 (2008), 10.1103/PhysRevLett.100.106804, Boudarham and Kociak Phys. Rev. B 85, 245447 (2012), 10.1103/PhysRevB.85.245447]; it makes it straightforward to predict or interpret phenomena already known for localized surface plasmons such as environment-related energy shifts or the possibility of 3D mapping of the related surface charge densities [Collins et al. ACS Photonics 2, 1628 (2015), 10.1021/acsphotonics.5b00421].

  3. Using the lambda function to evaluate probe measurements of charged dielectric surfaces

    DEFF Research Database (Denmark)

    Rerup, T. O.; Crichton, George C; McAllister, Iain Wilson

    1996-01-01

    The use of Pedersen's λ function to evaluate electrostatic probe measurements of charged dielectric surfaces is demonstrated. With a knowledge of the probe λ function, the procedure by which this function is employed is developed, and thereafter applied to a set of experimental measurements avail...

  4. Probing correlations of early magnetic fields using mu-distortion

    DEFF Research Database (Denmark)

    Ganc, Jonathan; Sloth, Martin Snoager

    2014-01-01

    the perturbations which produce the $\\mu$-distortion will be much smaller scale than the relevant density perturbations, the observation of this correlation is sensitive to the squeezed limit of $\\langle B^2\\zeta\\rangle$, which is naturally parameterized by $b_{\\text{NL}}$ (a parameter defined analogously to $f_{\\text......{NL}}$). We find that a PIXIE-like CMB experiments has a signal to noise $S/N\\approx 1.0 \\times b_{\\text{NL}} (\\tilde B_\\mu/10\\text{ nG})^2$, where $\\tilde B_\\mu$ is the magnetic field's strength on $\\mu$-distortion scales normalized to today's redshift; thus, a 10 nG field would be detectable with $b_{\\text...

  5. A dual mode targeting probe for distinguishing HER2-positive breast cancer cells using silica-coated fluorescent magnetic nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Li, Jia [Medical School Southeast University, Department of Ultrasonography, Zhongda Hospital (China); An, Yan-Li; Zang, Feng-Chao [Southeast University, Jiangsu Key Laboratory of Molecular and Functional Imaging (China); Zong, Shen-Fei; Cui, Yi-Ping, E-mail: cyp@seu.edu.cn [Southeast University, Advanced Photonics Center (China); Teng, Gao-Jun, E-mail: gjteng@vip.sina.com [Southeast University, Jiangsu Key Laboratory of Molecular and Functional Imaging (China)

    2013-10-15

    We report a composite nanoprobe based on silica-coated magnetic nanoparticles (NPs) for distinguishing breast cancers at different HER2 statuses. The nanoprobe has a core-shell structure, with Fe{sub 3}O{sub 4} NPs as the magnetic core and dye-embedded silica as the fluorescent shell, whose average size is about 150 nm. Besides, the outmost surfaces of the probes were modified with specific antibodies to endow the probe with a targeting ability. With such a structure, the nanoprobe can accomplish dual mode targeting of human breast cancer cells based on fluorescence and magnetic resonance imaging (MRI). In the experiments, three human breast cancer cell lines were used to test the targeting ability of the nanoprobe. Specifically, SKBR3 cells with a high HER2 expression level were used as the model target cells, while MCF7 cells with a lower HER2 expression levels and HER2-negative MDA-MB-231 cells were used as the controls. Both the fluorescence and MRI imaging results confirmed that the nanoprobe can distinguish three cancer cell lines with different HER2 expression levels. With the dual mode imaging and specific targeting properties, we anticipate that the presented nanoprobe may have a great potential in the diagnosis and treatment of cancerous diseases.

  6. A dual mode targeting probe for distinguishing HER2-positive breast cancer cells using silica-coated fluorescent magnetic nanoparticles

    Science.gov (United States)

    Li, Jia; An, Yan-Li; Zang, Feng-Chao; Zong, Shen-Fei; Cui, Yi-Ping; Teng, Gao-Jun

    2013-10-01

    We report a composite nanoprobe based on silica-coated magnetic nanoparticles (NPs) for distinguishing breast cancers at different HER2 statuses. The nanoprobe has a core-shell structure, with Fe3O4 NPs as the magnetic core and dye-embedded silica as the fluorescent shell, whose average size is about 150 nm. Besides, the outmost surfaces of the probes were modified with specific antibodies to endow the probe with a targeting ability. With such a structure, the nanoprobe can accomplish dual mode targeting of human breast cancer cells based on fluorescence and magnetic resonance imaging (MRI). In the experiments, three human breast cancer cell lines were used to test the targeting ability of the nanoprobe. Specifically, SKBR3 cells with a high HER2 expression level were used as the model target cells, while MCF7 cells with a lower HER2 expression levels and HER2-negative MDA-MB-231 cells were used as the controls. Both the fluorescence and MRI imaging results confirmed that the nanoprobe can distinguish three cancer cell lines with different HER2 expression levels. With the dual mode imaging and specific targeting properties, we anticipate that the presented nanoprobe may have a great potential in the diagnosis and treatment of cancerous diseases.

  7. Chaotic approach to evaluation of disturbed magnetic surfaces

    International Nuclear Information System (INIS)

    Kogoshi, Sumio; Mishimagi, Sigehiro; Yoshii, Keiichi; Maeda, Joji

    1998-01-01

    A circle mapping can approximately reproduce the cross section of magnetic surfaces and the value of the periodic driving force (K) at a magnetic island varies with the width of the magnetic island, which suggests the value of K is one of measures for the degradation of magnetic surfaces. The profile of a rotational transform has flat regions at the magnetic islands. The width of the flat region is proportional to the width of the magnetic island. Therefore it may be another measure of the degradation of magnetic surfaces. This method requires less data for the estimation than the usual method of calculating the width of magnetic islands. For collapsed magnetic surfaces that are produced by overlapping of two magnetic islands, the fractal dimension can effectively estimate the degradation of them. The fractal dimensions of cross sections of regular magnetic surfaces and clear magnetic islands are nearly 1, while that of a collapsed magnetic surface is about 1.2 in the present study. (author)

  8. Surface decorated Fe3O4 nanoparticles for magnetic hyperthermia

    Science.gov (United States)

    Gawali, Santosh L.; Barick, K. C.; Hassan, P. A.

    2017-05-01

    Magnetic nanoparticles have been widely investigated for their great potential in several biomedical applications such as magnetic hyperthermia, drug delivery and magnetic resonance imaging (MRI). We have developed a formulation in which the surface of Fe3O4 magnetic nanoparticles is decorated with succinic acid (SA) to provide enhanced colloidal stability in biological fluids while preserving their optimal magnetic properties. The successful surface decoration of particles with SA is evident from FTIR, TGA, DLS and zeta-potential measurements. XRD and TEM analysis revealed the formation of inverse spinel Fe3O4 nanoparticles of average size 10 nm. Our induction heating studies exhibited the excellent heating efficacy of these nanoparticles under applied AC magnetic field. The heating ability was found to be strongly dependent on the concentration of particles in magnetic suspension and applied AC magnetic field. Specifically, a novel water-dispersible surface decorated Fe3O4 nanoparticles formulation was developed for magnetic hyperthermia.

  9. DIII-D Equilibrium Reconstructions with New 3D Magnetic Probes

    Science.gov (United States)

    Lao, Lang; Strait, E. J.; Ferraro, N. M.; Ferron, J. R.; King, J. D.; Lee, X.; Meneghini, O.; Turnbull, A. D.; Huang, Y.; Qian, J. G.; Wingen, A.

    2015-11-01

    DIII-D equilibrium reconstructions with the recently installed new 3D magnetic diagnostic are presented. In addition to providing information to allow more accurate 2D reconstructions, the new 3D probes also provide useful information to guide computation of 3D perturbed equilibria. A new more comprehensive magnetic compensation has been implemented. Algorithms are being developed to allow EFIT to reconstruct 3D perturbed equilibria making use of the new 3D probes and plasma responses from 3D MHD codes such as GATO and M3D-C1. To improve the computation efficiency, all inactive probes in one of the toroidal planes in EFIT have been replaced with new probes from other planes. Other 3D efforts include testing of 3D reconstructions using V3FIT and a new 3D variational moment equilibrium code VMOM3D. Other EFIT developments include a GPU EFIT version and new safety factor and MSE-LS constraints. The accuracy and limitation of the new probes for 3D reconstructions will be discussed. Supported by US DOE under DE-FC02-04ER54698 and DE-FG02-95ER54309.

  10. RFID Antenna Near-field Characterization Using a New 3D Magnetic Field Probe

    Directory of Open Access Journals (Sweden)

    Kassem Jomaa

    2017-05-01

    Full Text Available In this paper the design of a new 3D magnetic field (H-field probe with a near-field scanning system is presented, then the near electromagnetic fields radiated by a Library RFID system is characterized. The proposed system is developed in order to determine the magnetic near-field emitted by electronic devices. The designed isotropic H-field probe consists of three orthogonal and identical loops each of diameter of 6 mm having 3 turns. The antenna factor of the designed probe is presented for a frequency range from 10 MHz to 1 GHz. The designed probe is tested and validated using a standard passive circuit as a device under test. An RFID reader antenna is also designed and simulated on HFSS (high frequency structural simulator and the radiated magnetic field, obtained by simulations, is then compared to the real measured one above the fabricated circuit. The obtained levels are checked if they satisfy the European and ICNIRP Electromagnetic Fields Guidelines.

  11. Interpreting the probe-surface interaction of surface measuring instruments, or what is a surface?

    Science.gov (United States)

    Leach, Richard; Weckenmann, Albert; Coupland, Jeremy; Hartmann, Wito

    2014-09-01

    When using dimensional measuring instruments it is assumed that there is a property of the object, which we call surface, that is present before during and after the measurement, i.e. the surface is a fundamental property of an object that can, by appropriate means, be used to measure geometry. This paper will attempt to show that the fundamental property ‘surface’ does not exist in any simple form and that all the information we can have about a surface is the measurement data, which will include measurement uncertainty. Measurement data, or what will be referred to as the measured surface, is all that really exists. In this paper the basic physical differences between mechanically, electromagnetically and electrically measured surfaces are highlighted and discussed and accompanied by measurement results on a roughness artefact.

  12. Interpreting the probe-surface interaction of surface measuring instruments, or what is a surface?

    International Nuclear Information System (INIS)

    Leach, Richard; Weckenmann, Albert; Hartmann, Wito; Coupland, Jeremy

    2014-01-01

    When using dimensional measuring instruments it is assumed that there is a property of the object, which we call surface, that is present before during and after the measurement, i.e. the surface is a fundamental property of an object that can, by appropriate means, be used to measure geometry. This paper will attempt to show that the fundamental property ‘surface’ does not exist in any simple form and that all the information we can have about a surface is the measurement data, which will include measurement uncertainty. Measurement data, or what will be referred to as the measured surface, is all that really exists. In this paper the basic physical differences between mechanically, electromagnetically and electrically measured surfaces are highlighted and discussed and accompanied by measurement results on a roughness artefact. (paper)

  13. Simultaneous surface and depth neural activity recording with graphene transistor-based dual-modality probes.

    Science.gov (United States)

    Du, Mingde; Xu, Xianchen; Yang, Long; Guo, Yichuan; Guan, Shouliang; Shi, Jidong; Wang, Jinfen; Fang, Ying

    2018-05-15

    Subdural surface and penetrating depth probes are widely applied to record neural activities from the cortical surface and intracortical locations of the brain, respectively. Simultaneous surface and depth neural activity recording is essential to understand the linkage between the two modalities. Here, we develop flexible dual-modality neural probes based on graphene transistors. The neural probes exhibit stable electrical performance even under 90° bending because of the excellent mechanical properties of graphene, and thus allow multi-site recording from the subdural surface of rat cortex. In addition, finite element analysis was carried out to investigate the mechanical interactions between probe and cortex tissue during intracortical implantation. Based on the simulation results, a sharp tip angle of π/6 was chosen to facilitate tissue penetration of the neural probes. Accordingly, the graphene transistor-based dual-modality neural probes have been successfully applied for simultaneous surface and depth recording of epileptiform activity of rat brain in vivo. Our results show that graphene transistor-based dual-modality neural probes can serve as a facile and versatile tool to study tempo-spatial patterns of neural activities. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Experimental study of the use of probe methods for diagnostic of low-temperature magnetized plasma

    OpenAIRE

    Zanáška, Michal

    2015-01-01

    The ball-pen probe is a relatively new diagnostic method, that has been designed for direct measurement of plasma potential in magnetized plasmas. Nowadays, it is routinely used at several high-temperature plasma devices in Europe and it has been tested also in conditions of low-temperature plasma, which are substantially different from that of high-temperature plasma. The measurements performed so far showed, that ball-pen probe could be used also in low-temperature plasma. However, more mea...

  15. Resolution limit of probe-forming systems with magnetic quadrupole lens triplets and quadruplets

    International Nuclear Information System (INIS)

    Ponomarev, A.G.; Melnik, K.I.; Miroshnichenko, V.I.; Storizhko, V.E.; Sulkio-Cleff, B.

    2003-01-01

    Over the past decade, in MeV ion beam microanalysis efforts to achieve a spatial resolution better than 0.1 μm with a beam current of ∼100 pA have been connected with microprobes of new generation where the probe is formed by means of separated magnetic quadrupole lens structures . However, as was pointed out in , no dramatic improvements in spatial resolution have been produced so far. For better understanding of the situation the authors carried out theoretical studies of multiparameter sets of probe-forming systems based on separated triplets and quadruplets of magnetic quadrupole lenses. Comparisons were made between the highest current values attained at different systems for a given beam spot size. The maximum parasitic sextupole and octupole field components were found whose contributions to spot broadening are tolerable. It is shown that the use of modern electrostatic accelerators and precision magnetic quadrupole lenses makes it possible to eliminate the effect of chromatic aberrations and second- and third-order parasitic aberrations resulting from distortions of the quadrupole lens symmetry. Therefore probe-forming systems with triplets and quadruplets of magnetic quadrupole lenses have a lower theoretical spatial resolution limit which is restricted mainly by intrinsic spherical third-order aberrations in state-of-the-art microprobes

  16. Magnetic micro-manipulations to probe the local physical properties of porous scaffolds and to confine stem cells.

    Science.gov (United States)

    Robert, Damien; Fayol, Delphine; Le Visage, Catherine; Frasca, Guillaume; Brulé, Séverine; Ménager, Christine; Gazeau, Florence; Letourneur, Didier; Wilhelm, Claire

    2010-03-01

    The in vitro generation of engineered tissue constructs involves the seeding of cells into porous scaffolds. Ongoing challenges are to design scaffolds to meet biochemical and mechanical requirements and to optimize cell seeding in the constructs. In this context, we have developed a simple method based on a magnetic tweezer set-up to manipulate, probe, and position magnetic objects inside a porous scaffold. The magnetic force acting on magnetic objects of various sizes serves as a control parameter to retrieve the local viscosity of the scaffolds internal channels as well as the stiffness of the scaffolds pores. Labeling of human stem cells with iron oxide magnetic nanoparticles makes it possible to perform the same type of measurement with cells as probes and evaluate their own microenvironment. For 18 microm diameter magnetic beads or magnetically labeled stem cells of similar diameter, the viscosity was equivalently equal to 20 mPa s in average. This apparent viscosity was then found to increase with the magnetic probes sizes. The stiffness probed with 100 microm magnetic beads was found in the 50 Pa range, and was lowered by a factor 5 when probed with cells aggregates. The magnetic forces were also successfully applied to the stem cells to enhance the cell seeding process and impose a well defined spatial organization into the scaffold. (c) 2009 Elsevier Ltd. All rights reserved.

  17. Bio-polymer coatings on neural probe surfaces: Influence of the initial sample composition

    Energy Technology Data Exchange (ETDEWEB)

    Chow, Winnie W.Y. [Department of Physics and Astronomy, Uppsala University, Box 516, 751 20 Uppsala (Sweden); Herwik, Stanislav; Ruther, Patrick [Department of Microsystems Engineering (IMTEK), University of Freiburg (Germany); Goethelid, Emmanuelle [Department of Physics and Astronomy, Uppsala University, Box 516, 751 20 Uppsala (Sweden); Oscarsson, Sven, E-mail: sven@svenoscarsson.com [Department of Organic Chemistry, Stockholm University, Arrhenius Laboratory, SE-106 91 Stockholm (Sweden)

    2012-08-01

    This paper presents the results of the study of hyaluronic acid (HyA) coating on two structural materials, silicon oxide (dielectric) surface and platinum (Pt) surface used for fabrication of probes developed for neurological investigations in the framework of the EU-project NeuroProbes. The silicon-based neural probes consist of multiple Pt electrodes on the probe shafts for neural recording applications. HyA coatings were proposed to apply on the probe surfaces to enhance the biocompatibility. This study aims at understanding the influence of the initial composition of the probe surface on the structure and morphology of HyA coating. HyA was chemically functionalized by SS-pyridin using (N-Succinimidyl 3-[2-pyridyldithio]-propionate) (SPDP) and was immobilized on the surfaces via a covalent bond. The dielectric and Pt surfaces were derivatized by use of (3-mercaptopropyl) methyldimethoxysilane (MPMDMS). The silanol groups in MPMDMS bind to the dielectric surface, leaving the thiol groups at the uppermost surface and the thiol groups then bind covalently to the functionalized HyA. On the Pt surface, it is the thiol group which binds on the Pt surface. The coated surfaces were characterized by X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM). A well-defined HyA layer was observed on both dielectric and Pt surfaces. The coating of two molecular weights (340 kDa and 1.3 MDa) of HyA was examined. The influence of the silanized layer on the HyA coating was also investigated.

  18. Atomic scale properties of magnetic Mn-based alloys probed by emission Mössbauer spectroscopy

    CERN Multimedia

    Mn-based alloys are characterized by a wealth of properties, which are of interest both from fundamental physics point of view and particularly attractive for different applications in modern technology: from magnetic storage to sensing and spin-based electronics. The possibility to tune their magnetic properties through post-growth thermal processes and/or stoichiometry engineering is highly important in order to target different applications (i.e. Mn$_{x}$Ga) or to increase their Curie temperature above room temperature (i.e. off-stoichiometric MnSi). In this project, the Mössbauer effect will be applied at $^{57}$Fe sites following implantation of radioactive $^{57}$Mn, to probe the micro-structure and magnetism of Mn-based alloys on the atomic-scale. The proposed experimental plan is devoted to establish a direct correlation between the local structure and bulk magnetism (and other physical properties) of Mn-based alloys.

  19. Sensor probes and phantoms for advanced transcranial magnetic stimulation system developments

    Science.gov (United States)

    Meng, Qinglei; Patel, Prashil; Trivedi, Sudhir; Du, Xiaoming; Hong, Elliot; Choa, Fow-Sen

    2015-05-01

    Transcranial magnetic stimulation (TMS) has become one of the most widely used noninvasive method for brain tissue stimulation and has been used as a treatment tool for various neurological and psychiatric disorders including migraine, stroke, Parkinson's disease, dystonia, tinnitus and depression. In the process of developing advanced TMS deep brain stimulation tools, we need first to develop field measurement devices like sensory probes and brain phantoms, which can be used to calibrate the TMS systems. Currently there are commercially available DC magnetic or electric filed measurement sensors, but there is no instrument to measure transient fields. In our study, we used a commercial figure-8 shaped TMS coil to generate transient magnetic field and followed induced field and current. The coil was driven by power amplified signal from a pulse generator with tunable pulse rate, amplitude, and duration. In order to obtain a 3D plot of induced vector electric field, many types of probes were designed to detect single component of electric-field vectors along x, y and z axis in the space around TMS coil. We found that resistor probes has an optimized signal-to-noise ratio (SNR) near 3k ohm but it signal output is too weak compared with other techniques. We also found that inductor probes can have very high output for Curl E measurement, but it is not the E-field distribution we are interested in. Probes with electrical wire wrapped around iron coil can directly measure induced E-field with high sensitivity, which matched computer simulation results.

  20. Beating of magnetic oscillations in a graphene device probed by quantum capacitance

    KAUST Repository

    Tahir, M.

    2012-07-05

    We report the quantum capacitance of a monolayergraphene device in an external perpendicular magnetic field including the effects of Rashba spin-orbit interaction(SOI). The SOI mixes the spin up and spin down states of neighbouring Landau levels into two (unequally spaced) energy branches. In order to investigate the role of the SOI for the electronic transport, we study the density of states to probe the quantum capacitance of monolayergraphene.SOIeffects on the quantum magnetic oscillations (Shubnikov de Haas and de Hass-van Alphen) are deduced from the quantum capacitance.

  1. The use of probe characteristics in plasma in the presence of a magnetic field (1960)

    International Nuclear Information System (INIS)

    Brunet, A.; Geller, R.; Leroy, J.

    1960-01-01

    In this article we recall the principal methods of interpretation of probe characteristics in plasma in the presence of magnetic fields. Our purpose is to resume and to present the methods in such a form as to be immediately applicable in a particular case. This article is therefore principally useful to experimenters. Finally we expose our practical view points by comparing of experimental methods. (author) [fr

  2. Surface magnetic enhancement for coal cleaning

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, J.Y.

    1989-01-01

    The progress achieved during this quarter includes the ten months shelf life study of magnetizing reagent, the effect of cation regulators on minerals and coals, the combination effect of depressant and activator on the adsorption of magnetizing reagent, optimum magnetite size for magnetizing reagent, and the magnetic field strength for separating magnetic enhanced minerals. The work is generally on schedule with the original plan. The Phase I study (a fundamental study) is nearly completed. Selective conditions for adsorbing magnetizing reagent on minerals have been identified. The work for the next quarter will be mainly on the Phase II study. Coal will be selected, procured, characterized, and processed.

  3. In situ magnetic compensation for potassium spin-exchange relaxation-free magnetometer considering probe beam pumping effect

    Energy Technology Data Exchange (ETDEWEB)

    Fang, Jiancheng; Wang, Tao, E-mail: wangtaowt@aspe.buaa.edu.cn; Quan, Wei; Yuan, Heng; Li, Yang [School of Instrument Science and Opto-Electronics Engineering, Beihang University, Beijing 100191 (China); Zhang, Hong; Zou, Sheng [School of Instrument Science and Engineering, Southeast University, Nanjing 210096 (China)

    2014-06-15

    A novel method to compensate the residual magnetic field for an atomic magnetometer consisting of two perpendicular beams of polarizations was demonstrated in this paper. The method can realize magnetic compensation in the case where the pumping rate of the probe beam cannot be ignored. In the experiment, the probe beam is always linearly polarized, whereas, the probe beam contains a residual circular component due to the imperfection of the polarizer, which leads to the pumping effect of the probe beam. A simulation of the probe beam's optical rotation and pumping rate was demonstrated. At the optimized points, the wavelength of the probe beam was optimized to achieve the largest optical rotation. Although, there is a small circular component in the linearly polarized probe beam, the pumping rate of the probe beam was non-negligible at the optimized wavelength which if ignored would lead to inaccuracies in the magnetic field compensation. Therefore, the dynamic equation of spin evolution was solved by considering the pumping effect of the probe beam. Based on the quasi-static solution, a novel magnetic compensation method was proposed, which contains two main steps: (1) the non-pumping compensation and (2) the sequence compensation with a very specific sequence. After these two main steps, a three-axis in situ magnetic compensation was achieved. The compensation method was suitable to design closed-loop spin-exchange relaxation-free magnetometer. By a combination of the magnetic compensation and the optimization, the magnetic field sensitivity was approximately 4 fT/Hz{sup 1/2}, which was mainly dominated by the noise of the magnetic shield.

  4. Negligible water surface charge determined using Kelvin probe and total reflection X-ray fluorescence techniques.

    Science.gov (United States)

    Shapovalov, Vladimir L; Möhwald, Helmuth; Konovalov, Oleg V; Knecht, Volker

    2013-09-07

    The water surface charge has been extensively debated in recent decades. Electrophoretic mobilities of air bubbles in water and disjoining pressures between the surfaces of aqueous films suggest that the surface of water exhibits a significant negative charge. This is commonly attributed to a strong adsorption of hydroxide ions at the interface, though spectroscopic measurements and simulation studies suggest surface depletion of hydroxide ions. Alternatively, the negative surface charge could arise from surface contamination with trace charged surfactants. We have probed the variation in the surface charge of water with pH by measuring surface potentials using the Kelvin probe technique. Independently, the abundance in the interfacial layer of "reporter ions" (Rb(+) and Br(-)), which must be affected by a charged surface, has been monitored using the total reflection X-ray fluorescence (TRXF) technique. Special care was taken to prove the high sensitivity of this technique as well as to avoid surface contaminants. The magnitude of the surface charge was found to be below 1 e per 500 nm(2) (TRXF). No evidence of variations in the surface potential between pH 2-3 and pH 9-12 was detected within the accuracies of the methods (5 mV for Kelvin probe and 2 mV for TRXF). Hence, our findings suggest that the clean water surface exhibits negligible charge in a wide pH range.

  5. Measurement of magnetic surfaces on the Compact Auburn Torsatron

    International Nuclear Information System (INIS)

    Henderson, M.A.; Gandy, R.F.; Hanson, J.D.; Knowlton, S.F.; Swanson, D.G.

    1992-01-01

    The magnetic flux surfaces of the Compact Auburn Torsatron have been experimentally mapped in a variety of magnetic configurations. The magnetic surface mapping was done using the phosphor screen technique. The results are compared with an extensive computer model in order to validate the design coil structure and determine what modifications are needed to correct any minor winding errors. In initial field mapping experiments, a large up--down asymmetry was identified in the vacuum magnetic surfaces. A set of mapping studies was used to characterize the error through addition of terms to the coil winding law. The error was corrected with the use of a radial trim coil

  6. Isolation of residuals using trend surface analysis to magnetic data ...

    African Journals Online (AJOL)

    Polynomial surfaces of various degrees are fitted to a magnetic data of Awo area, southwestern Nigeria with the aim of isolating the residuals of the area associated with mineralogy. The fourth degree surface correlates better with the magnetic map of the study area. The residualized data were obtained by subtracting the ...

  7. Enhancement of surface magnetism due to bulk bond dilution

    International Nuclear Information System (INIS)

    Tsallis, C.; Sarmento, E.F.; Albuquerque, E.L. de

    1985-01-01

    Within a renormalization group scheme, the phase diagram of a semi-infinite simple cubic Ising ferromagnet is discussed, with arbitrary surface and bulk coupling constants, and including possible dilution of the bulk bonds. It is obtained that dilution makes easier the appearance of surface magnetism in the absence of bulk magnetism. (Author) [pt

  8. Conformation of bovine submaxillary mucin layers on hydrophobic surface as studied by biomolecular probes

    DEFF Research Database (Denmark)

    Pakkanen, Kirsi I.; Madsen, Jan Busk; Lee, Seunghwan

    2015-01-01

    non-linear responses with increasing surface concentration. The results from this study support the conventional amphiphilic, triblock model of BSM in the adsorption onto hydrophobic surface from aqueous solution.The biomolecular probe-based approaches employed in this study, however, provided further...

  9. Surface-sensitive conductivity measurement using a micro multi-point probe approach

    DEFF Research Database (Denmark)

    Perkins, Edward; Barreto, Lucas; Wells, Justin

    2013-01-01

    measurements with an equidistant four-point probe for a wide range of contact spacings. In this way, it is possible to distinguish between bulk-like and surface-like conduction. The paper describes the design of the instrument and the approach to data and error analysis. Application examples are given......An instrument for microscale electrical transport measurements in ultra-high vacuum is presented. The setup is constructed around collinear lithographically-created multi-point probes with a contact spacing down to 500 nm. Most commonly, twelve-point probes are used. These probes are approached...... to the surface via piezoelectric positioners. Standard four-point resistance measurements can be performed using any combination of contacts out of the twelve available. Current/voltage measurements are taken semi-automatically for a variety of the possible contact configurations, effectively emulating...

  10. Can We Probe the Conductivity of the Lithosphere and Upper Mantle Using Satellite Tidal Magnetic Signals?

    Science.gov (United States)

    Schnepf, N. R.; Kuvshinov, A.; Sabaka, T.

    2015-01-01

    A few studies convincingly demonstrated that the magnetic fields induced by the lunar semidiurnal (M2) ocean flow can be identified in satellite observations. This result encourages using M2 satellite magnetic data to constrain subsurface electrical conductivity in oceanic regions. Traditional satellite-based induction studies using signals of magnetospheric origin are mostly sensitive to conducting structures because of the inductive coupling between primary and induced sources. In contrast, galvanic coupling from the oceanic tidal signal allows for studying less conductive, shallower structures. We perform global 3-D electromagnetic numerical simulations to investigate the sensitivity of M2 signals to conductivity distributions at different depths. The results of our sensitivity analysis suggest it will be promising to use M2 oceanic signals detected at satellite altitude for probing lithospheric and upper mantle conductivity. Our simulations also suggest that M2 seafloor electric and magnetic field data may provide complementary details to better constrain lithospheric conductivity.

  11. Surface morphology of contact lenses probed with microscopy techniques

    Czech Academy of Sciences Publication Activity Database

    Guryča, Vilém; Hobzová, Radka; Přádný, Martin; Širc, Jakub; Michálek, Jiří

    2007-01-01

    Roč. 30, č. 4 (2007), s. 215-222 ISSN 1367-0484 R&D Projects: GA AV ČR 1QS400500558 Institutional research plan: CEZ:AV0Z40500505 Keywords : atomic force microscopy * scanning electron microscopy * surface roughness Subject RIV: CD - Macromolecular Chemistry

  12. ANALYSIS OF SURFACE DEFECTS OF ALUMINUM AND ITS ALLOYS WITH A SCANNING KELVIN PROBE

    Directory of Open Access Journals (Sweden)

    A. K. Tyavlovsky

    2017-01-01

    Full Text Available Currently, the use of probe electrometry in non-destructive testing is constrained by the complexity of measurement results interpretation. An output signal of electrometric probe depends on a number of physical and chemical parameters of surface including chemical composition variations, stresses, dislocations, crystallographic orientation of a surface, etc. The study aims to the use of probe electrometry methods for nondestructive testing and analysis of precision metal surfaces’ defects after different treatment or processing.Control of surface defects of aluminum and its alloys was performed with a scanning Kelvin probe technique. The results of scanning were plotted in a form of contact potential difference (CPD distribution map. Additionally, a histogram of CPD values distribution and statistical characteristics including the expectation of CPD mean value and histogram half-width were calculated either for the whole distribution or for each individual mode in a case of multimodal distribution.The spatial CPD distribution of A99 aluminum and AMG-2 alloy surfaces after electrochemical polishing and diamond finishing was studied. An additional study was held for AMG-2 surface after the formation of 30 microns thick specific nanostructured alumina oxide surface layer. Higher quality surfaces have characterized as more homogeneous distribution of the physical properties (at half-width distribution histogram. Surfaces with higher mechanical strength and overall better mechanical properties found to have lower CPD values that correspond to higher electron work function and surface energy. The presence of the second mode in the CPD distribution histogram indicates the significant proportion of defect areas on the sample surface.Analysis of visualized CPD distribution maps using defined criteria allows detecting and characterizing such defects as residual stress areas, areas with reduced microhardness, surface contamination spots, corrosion

  13. Micro reflectance difference techniques: Optical probes for surface exploration

    Energy Technology Data Exchange (ETDEWEB)

    Lastras-Martinez, L.F.; Del Pozo-Zamudio, O.; Herrera-Jasso, R.; Ulloa-Castillo, N.A.; Balderas-Navarro, R.E.; Ortega-Gallegos, J.; Lastras-Martinez, A. [Instituto de Investigacion en Comunicacion Optica, Universidad Autonoma de San Luis Potosi, Alvaro Obregon 64, 78000 San Luis Potosi, S.L.P. (Mexico)

    2012-06-15

    Micro reflectance difference spectroscopy ({mu}-RDS) is a promising tool for the in-situ and ex-situ characterization of semiconductors surfaces and interfaces. We discuss and compare two different approaches used to measure {mu}-RD spectra. One is based on a charge-coupled device (CCD) camera, while the other uses a laser and a XY translation stage. To show the performance of these systems, we have measured surface optical anisotropies of GaSb(001) sample on which anisotropic strains have been generated by preferential mechanical polishing along [110] and [1 anti 10] directions. The spectrometers are complementary and the selection of one of them depends on the sample to be investigated and on experimental conditions. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  14. Probing the selectivity of a nanostructured surface by xenon adsorption.

    Science.gov (United States)

    Widmer, Roland; Passerone, Daniele; Mattle, Thomas; Sachdev, Hermann; Gröning, Oliver

    2010-04-01

    Surface-supported molecular self-assembly with the goal to produce highly ordered, functional supramolecular nanostructures are often realized using nanopatterned surfaces, which exhibit long range - ideally periodic - modulations of the molecule adsorption properties. To elucidate the physical origins of the site-specific adsorption properties of such a nanopatterned substrate, we investigated the temperature-dependent microscopic structure and the dynamics of adsorbed Xe at different temperatures on single-sheet h-BN on a Rh(111) nanomesh. In combination with molecular dynamics simulations we show that the site-specific adsorption arises from two different interactions of similar magnitude with respect to their lateral variations. The first can be attributed to a van der Waals type interaction, whereas the second originates from lateral variation of the electrostatic surface potential and is of polarization type. Both types lead to an adsorption energy minimum at the rim of the nanomesh pore and are therefore responsible for stabilizing dynamic and static Xe rings in these pores. The insight into this interplay of interactions should pave the way to gain a more general knowledge on such site-specific adsorption processes.

  15. Probing Magnetism in the Vortex Phase of PuCoGa_{5} by X-Ray Magnetic Circular Dichroism.

    Science.gov (United States)

    Magnani, N; Eloirdi, R; Wilhelm, F; Colineau, E; Griveau, J-C; Shick, A B; Lander, G H; Rogalev, A; Caciuffo, R

    2017-10-13

    We measure x-ray magnetic circular dichroism (XMCD) spectra at the Pu M_{4,5} absorption edges from a newly prepared high-quality single crystal of the heavy-fermion superconductor ^{242}PuCoGa_{5}, exhibiting a critical temperature T_{c}=18.7  K. The experiment probes the vortex phase below T_{c} and shows that an external magnetic field induces a Pu 5f magnetic moment at 2 K equal to the temperature-independent moment measured in the normal phase up to 300 K by a superconducting quantum interference device. This observation is in agreement with theoretical models claiming that the Pu atoms in PuCoGa_{5} have a nonmagnetic singlet ground state resulting from the hybridization of the conduction electrons with the intermediate-valence 5f electronic shell. Unexpectedly, XMCD spectra show that the orbital component of the 5f magnetic moment increases significantly between 30 and 2 K; the antiparallel spin component increases as well, leaving the total moment practically constant. We suggest that this indicates a low-temperature breakdown of the complete Kondo-like screening of the local 5f moment.

  16. Ultrasound surface probe as a screening method for evaluating the patients with blunt abdominal trauma

    Directory of Open Access Journals (Sweden)

    Mohammad Nasr-Esfahani

    2014-01-01

    Full Text Available Background: Blunt abdominal trauma is one of the causes of mortality in emergency department. Free fluid in the abdomen due to intra-abdominal blunt trauma can be determined by the surface probe of ultrasound. Since the importance of this free fluid in hemodynamic stable patients with blunt trauma is associated with the unknown outcome for surgeons, this study was performed to evaluate the role of ultrasound surface probe as a screening method in evaluating the patients with blunt abdominal trauma. Materials and Methods: A descriptive-analytical study was done on 45 patients with blunt abdominal trauma and hemodynamic stability. The patients were evaluated twice during the three-hours, including repeated ultrasound surface probe and clinical examinations. Computerized tomography was also performed. The patients were divided based on the amount of the free fluid in the abdomen during the evaluations into two groups: Fixed or increased, and decreased free fluid. The results of the different evaluated methods were compared using the sensitivity and specificity. Results: From 17 patients with CT abnormalities, free fluid increased in 14 patients (82.4%. Free fluid was decreased in three patients who were discharged well from the surgery service without any complication. Surface probe in prognosis detection had a sensitivity of 82.4% and specificity of 92.9%. The percentage of false positive and negative ultrasound compared with CT scan was 7.1% and 17.6%. Also, positive and negative predictive value of the ultrasound with surface probe was 87.5% and 89.7% respectively. Conclusion: The use of the ultrasound with surface probe in the diagnosis of free fluid in blunt abdominal trauma in hemodynamic stable patients can be considered as a useful screening method.

  17. Resolution limit of probe-forming systems with magnetic quadrupole lens triplets and quadruplets

    CERN Document Server

    Ponomarev, A G; Miroshnichenko, V I; Storizhko, V E; Sulkio-Cleff, B

    2003-01-01

    Over the past decade, in MeV ion beam microanalysis efforts to achieve a spatial resolution better than 0.1 mu m with a beam current of approx 100 pA have been connected with microprobes of new generation where the probe is formed by means of separated magnetic quadrupole lens structures . However, as was pointed out in , no dramatic improvements in spatial resolution have been produced so far. For better understanding of the situation the authors carried out theoretical studies of multiparameter sets of probe-forming systems based on separated triplets and quadruplets of magnetic quadrupole lenses. Comparisons were made between the highest current values attained at different systems for a given beam spot size. The maximum parasitic sextupole and octupole field components were found whose contributions to spot broadening are tolerable. It is shown that the use of modern electrostatic accelerators and precision magnetic quadrupole lenses makes it possible to eliminate the effect of chromatic aberrations and s...

  18. Magnetic field and magnetic isotope effects in organic photochemical reactions. A novel probe of reaction mechanisms and a method for enrichment of magnetic isotopes

    International Nuclear Information System (INIS)

    Turro, N.J.; Kraeutler, B.

    1980-01-01

    A brief qualitative description of the theory of intersystem crossing (ISC) in radical pairs is presented. It provides a simple unified theoretical basis for understanding chemically induced nuclear polarization (CIDNP), the magnetic spin isotope effect, and magnetic field effects on chemical reactions. Examples are given in which the magnetic spin isotope effect is employed to separate 13 C (a magnetic isotope) from 12 C (a nonmagnetic isotope) more efficiently than any mechanism involving a conventional mass isotope effect, and to separate selectively 17 O (a magnetic isotope) from 16 O and 18 O (nonmagnetic isotope), which is impossible via a conventional mass isotope effect. Examples are also provided for which the magnetic field effect is utilized to control the efficiency of cage reactions of radical pairs. The observation of magnetic isotope and magnetic field effects on the photolysis of dibenzyl ketone in micellar solution is not an isolated finding. Numerous other ketones (phenyl adamantyl ketone, phenyl benzyl ketone, etc.) have been found to exhibit analogous behavior. The ideas discussed may be employed in principle, to design chemical reactions that will separate magnetic isotopes from their nonmagnetic colleagues. The key features are the requirement of a singlet-triplet crossing along the reaction coordinate, the availability of a hyperfine hole at the molecular geometry corresponding to the hole, and sufficient time for the representative point to find the hole when it arrives in the region of phase space corresponding to the hole. Magnetic field and magnetic isotope effects provide a complement to CIDNP for probing mechanisms of radical reactions

  19. Electronic transport at semiconductor surfaces - from point-contact transistor to micro-four-point probes

    DEFF Research Database (Denmark)

    Hasegawa, S.; Grey, Francois

    2002-01-01

    show that this type of conduction is measurable using new types of experimental probes, such as the multi-tip scanning tunnelling microscope and the micro-four-point probe. The resulting electronic transport properties are intriguing, and suggest that semiconductor surfaces should be considered...... of the first point-contact transistors, and led to the successful fabrication of field-effect transistors. However, to this day, one property of semiconductor surface states remains poorly understood, both theoretically and experimentally. That is the conduction of electrons or holes directly through...

  20. Surface ferro (or antiferro) magnetism in bulk antiferro (or ferro) magnets: renormalization group analysis

    International Nuclear Information System (INIS)

    Sarmento, E.F.; Tsallis, C.

    1985-01-01

    The renormalization group techniques are applied, for the first time, to surface magnetism in bulk magnets, for all signs of surface and bulk coupling constants. The g-state Potts model is specifically focused, and a interesting q-evolution of the phase diagram is exhibited. In particular the Ising model (q=2) presents a remarkable feature: surface ferro (or antiferro) magnetism can disappear while heating an antiferro (or ferro) magnet, and reappear again for higher temperatures, before entering in the paramagnetic phase. (Author) [pt

  1. Controlled Clustering of Gold Nanoparticles using Solid-support for Surface-enhanced Raman Spectroscopic Probes

    International Nuclear Information System (INIS)

    Chang, Hyejin; Chae, Jinjoo; Jeong, Hong; Kang, Homan; Lee, Yoonsik

    2014-01-01

    We fabricated small clusters of gold nanoparticles by using solid-supported aggregation of gold nanoparticles. The fabricated Au nanoclusters consisting mainly of dimers showed homogeneous characteristics in cluster size and SERS intensity. The SERS enhancement of 4-ABT molecules in an effective area within 2-nm gap appeared to be approximately 10. Detachment process by ultrasonication was successively carried out in order to use the nanoclusters as SERS probes. The possibility of these clusters as SERS probe was proved in terms of signal and cluster size. Single molecule-level sensitivity of surface-enhanced Raman scattering (SERS) was known approximately fifteen years ago. Ever since there have been many different applications benefiting from the ultra-high sensitivity such as single molecule detection, chemical sensing and bio-molecular probes. Especially, SERS has drawn much attention in bio-multiplexing probes owing to its unique optical characteristics claiming extremely narrow bandwidth, high sensitivity of light signals, and non-bleaching feature

  2. Electronic transport at semiconductor surfaces - from point-contact transistor to micro-four-point probes

    DEFF Research Database (Denmark)

    Hasegawa, S.; Grey, Francois

    2002-01-01

    show that this type of conduction is measurable using new types of experimental probes, such as the multi-tip scanning tunnelling microscope and the micro-four-point probe. The resulting electronic transport properties are intriguing, and suggest that semiconductor surfaces should be considered......The electrical properties of semiconductor surfaces have played a decisive role in one of the most important discoveries of the last century, transistors. In the 1940s, the concept of surface states-new electron energy levels characteristic of the surface atoms-was instrumental in the fabrication...... of the first point-contact transistors, and led to the successful fabrication of field-effect transistors. However, to this day, one property of semiconductor surface states remains poorly understood, both theoretically and experimentally. That is the conduction of electrons or holes directly through...

  3. Effect of iron on vanadium (001) strained surface magnetism

    Energy Technology Data Exchange (ETDEWEB)

    Elzain, M; Al-Barwani, M; Gismelseed, A; Al-Rawas, A; Yousif, A; Widatallah, H; Bouziane, K; Al-Omari, I, E-mail: elzain@squ.edu.o [Department of Physics, College Of Science, Box 36, Sultan Qaboos University, Al Khod 123 (Oman)

    2010-03-01

    The magnetism of the vanadium (001) surface has been a controversial subject on both theoretical and experiment fronts. Both strongly ferromagnetic and paramagnetic phases were reported. We have used the first principle full-potential linearized-augmented plane waves (FP-LAPW) as implemented in WIEN2k package to study the magnetic properties of strained surfaces of vanadium films as a function of film thickness. We found that for films thicker than about 11 monolayers, the magnetism of the strained surfaces converge to a constant value of about 0.15{mu}{sub B}. Introduction of Fe monolayers and impurities at the centre of the films affects the magnetic structure of thin films but has no influence on the surface magnetism of thicker films. For Fe monolayers positioned at the centre of thick films, the Fe atoms maintain magnetic moment of order 0.86{mu}{sub B}, a quadruple splitting of order -0.3 mm/s and a small negative isomer shift, while an Fe impurity has vanishing hyperfine fields and magnetic moment. In addition we have varied the location of the Fe monolayer and impurity within the V films and found that their position affects the surface magnetism.

  4. Competing magnetic fluctuations in Sr3Ru2O7 probed by Ti doping

    DEFF Research Database (Denmark)

    Hooper, J.; Fang, M.H.; Zhou, M.

    2007-01-01

    We report the effect of nonmagnetic Ti4+ impurities on the electronic and magnetic properties of Sr3Ru2O7. Small amounts of Ti suppress the characteristic peak in magnetic susceptibility near 16 K and result in a sharp upturn in specific heat. The metamagnetic quantum phase transition and related...... anomalous features are quickly smeared out by small amounts of Ti. These results provide strong evidence for the existence of competing magnetic fluctuations in the ground state of Sr3Ru2O7. Ti doping suppresses the low-temperature antiferromagnetic interactions that arise from Fermi surface nesting...

  5. Probing surfaces with single-polymer atomic force microscope experiments.

    Science.gov (United States)

    Friedsam, C; Gaub, H E; Netz, R R

    2006-03-01

    In the past 15 years atomic force microscope (AFM) based force spectroscopy has become a versatile tool to study inter- and intramolecular interactions of single polymer molecules. Irreversible coupling of polymer molecules between the tip of an AFM cantilever and the substrate allows one to study the stretching response up to the high force regime of several nN. For polymers that glide or slip laterally over the surface with negligible friction, on the other hand, the measured force profiles exhibit plateaus which allow one to extract the polymer adsorption energies. Long-term stable polymer coatings of the AFM tips allow for the possibility of repeating desorption experiments from solid supports with individual molecules many times, yielding good sampling statistics and thus reliable estimates for adsorption energies. In combination with recent advances in theoretical modeling, a detailed picture of the conformational statistics, backbone elasticity, and the adsorption characteristics of single polymer molecules is obtained.

  6. In vitro study of proteins surface activity by tritium probe

    International Nuclear Information System (INIS)

    Chernysheva, M.G.; Badun, G.A.

    2010-01-01

    A new technique for in vitro studies of biomacromolecules interactions, their adsorption at aqueous/organic liquid interfaces and distribution in the bulk of liquid/liquid systems was developed. The method includes (1) tritium labeling of biomolecules by tritium thermal activation method and (2) scintillation phase step with organic phase, which can be concerned as a model of cellular membrane. Two globular proteins lysozyme and human serum albumin tested. We have determined the conditions of tritium labeling when labeled by-products can be easy separated by means of dialysis and size-exclusion chromatography. Scintillation phase experiments were conducted for three types of organic liquids. Thus, the influences of the nature of organic phase on proteins adsorption and its distribution in the bulk of aqueous/organic liquid system were determined. It was found that proteins possess high surface activity at aqueous/organic liquid interface. Furthermore, values of hydrophobicity of globular proteins were found by the experiment. (author)

  7. Design and validation of the ball-pen probe for measurements in a low-temperature magnetized plasma

    International Nuclear Information System (INIS)

    Bousselin, G.; Cavalier, J.; Pautex, J. F.; Heuraux, S.; Lemoine, N.; Bonhomme, G.

    2013-01-01

    Ball-pen probes have been used in fusion devices for direct measurements of the plasma potential. Their application in low-temperature magnetized plasma devices is still subject to studies. In this context, a ball-pen probe has been recently implemented on the linear plasma device Mirabelle. Produced by a thermionic discharge, the plasma is characterized by a low electron temperature and a low density. Plasma confinement is provided by an axial magnetic field that goes up to 100 mT. The principle of the ball-pen probe is to adjust the saturation current ratio to 1 by reducing the electron current contribution. In that case, the floating potential of the probe is close to the plasma potential. A thorough study of the ball-pen probe operation is performed for different designs of the probe over a large set of plasma conditions. Comparisons between ball-pen, Langmuir, and emissive probes are conducted in the same plasma conditions. The ball-pen probe is successfully measuring the plasma potential in these specific plasma conditions only if an adapted electronics and an adapted probe size to the plasma characteristic lengths (λ D , ρ ce ) are used.

  8. Design and validation of the ball-pen probe for measurements in a low-temperature magnetized plasma.

    Science.gov (United States)

    Bousselin, G; Cavalier, J; Pautex, J F; Heuraux, S; Lemoine, N; Bonhomme, G

    2013-01-01

    Ball-pen probes have been used in fusion devices for direct measurements of the plasma potential. Their application in low-temperature magnetized plasma devices is still subject to studies. In this context, a ball-pen probe has been recently implemented on the linear plasma device Mirabelle. Produced by a thermionic discharge, the plasma is characterized by a low electron temperature and a low density. Plasma confinement is provided by an axial magnetic field that goes up to 100 mT. The principle of the ball-pen probe is to adjust the saturation current ratio to 1 by reducing the electron current contribution. In that case, the floating potential of the probe is close to the plasma potential. A thorough study of the ball-pen probe operation is performed for different designs of the probe over a large set of plasma conditions. Comparisons between ball-pen, Langmuir, and emissive probes are conducted in the same plasma conditions. The ball-pen probe is successfully measuring the plasma potential in these specific plasma conditions only if an adapted electronics and an adapted probe size to the plasma characteristic lengths (λ(D), ρ(ce)) are used.

  9. Theoretical Investigation of Dynamic Properties of Magnetic Molecule Systems as Probed by NMR and Pulsed Fields Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Rousochatzakis, Ioannis [Iowa State Univ., Ames, IA (United States)

    2005-12-17

    The field of molecular magnetism[l-6] has become a subject of intense theoretical and experimental interest and has rapidly evolved during the last years. This inter-disciplinary field concerns magnetic systems at the molecular or "nanoscopic" level, whose realization has become feasible due to recent advances in the field of chemical synthesis. The present theoretical work provides a first step towards exploiting the possibilities that are offered by probing magnetic molecules using external magnetic fields with high sweep rates. These probes, apart for providing information specific to magnetic molecules, offer the possibility of conducting a detailed study of the relaxational behavior of interacting spin systems as a result of their coupling with a "heat bath" and in particular the excitations of the host lattice. Development of a broad theoretical framework for dealing with relaxational phenomena induced by dynamical magnetic fields is indeed a worthy goal.

  10. Scanning Hall Probe Microscopy of Magnetic Vortices inVery Underdoped yttrium-barium-copper-oxide

    Energy Technology Data Exchange (ETDEWEB)

    Guikema, Janice Wynn; /SLAC, SSRL

    2005-12-02

    Since their discovery by Bednorz and Mueller (1986), high-temperature cuprate superconductors have been the subject of intense experimental research and theoretical work. Despite this large-scale effort, agreement on the mechanism of high-T{sub c} has not been reached. Many theories make their strongest predictions for underdoped superconductors with very low superfluid density n{sub s}/m*. For this dissertation I implemented a scanning Hall probe microscope and used it to study magnetic vortices in newly available single crystals of very underdoped YBa{sub 2}Cu{sub 3}O{sub 6+x} (Liang et al. 1998, 2002). These studies have disproved a promising theory of spin-charge separation, measured the apparent vortex size (an upper bound on the penetration depth {lambda}{sub ab}), and revealed an intriguing phenomenon of ''split'' vortices. Scanning Hall probe microscopy is a non-invasive and direct method for magnetic field imaging. It is one of the few techniques capable of submicron spatial resolution coupled with sub-{Phi}{sub 0} (flux quantum) sensitivity, and it operates over a wide temperature range. Chapter 2 introduces the variable temperature scanning microscope and discusses the scanning Hall probe set-up and scanner characterizations. Chapter 3 details my fabrication of submicron GaAs/AlGaAs Hall probes and discusses noise studies for a range of probe sizes, which suggest that sub-100 nm probes could be made without compromising flux sensitivity. The subsequent chapters detail scanning Hall probe (and SQUID) microscopy studies of very underdoped YBa{sub 2}Cu{sub 3}O{sub 6+x} crystals with T{sub c} {le} 15 K. Chapter 4 describes two experimental tests for visons, essential excitations of a spin-charge separation theory proposed by Senthil and Fisher (2000, 2001b). We searched for predicted hc/e vortices (Wynn et al. 2001) and a vortex memory effect (Bonn et al. 2001) with null results, placing upper bounds on the vison energy inconsistent with

  11. Li-ion battery ageing model parameter: SEI layer analysis using magnetic field probing

    Directory of Open Access Journals (Sweden)

    Parmender Singh

    2018-02-01

    Full Text Available With the growing usage of lithium-ion (Li-ion batteries in various applications from stationary applications to automotive industries, their ageing mechanism and its influencing factors have become a big concern today. Ageing may be defined as deterioration in the performance of the battery due to irreversible physical and chemical changes like internal resistance rise, electrolyte decompositions, electrodes cracking and solid electrolyte interphase (SEI modification/growth. The aim of this research article is to study and analyse the behaviour of SEI layer growth at the anode using a novel non-invasive magnetic field probing (MFP. A 3-d model based upon well-known John Newman’s pseudo 2-d approach has been developed in COMSOL Multiphysics®. It is observed that the magnetic field response (MFR is inversely related to SEI growth. Anode’s state of charge (SoC response with SEI layer and MFR is also studied.

  12. How to probe transverse magnetic anisotropy of a single-molecule magnet by electronic transport?

    Science.gov (United States)

    Misiorny, M.; Burzuri, E.; Gaudenzi, R.; Park, K.; Leijnse, M.; Wegewijs, M.; Paaske, J.; Cornia, A.; van der Zant, H.

    We propose an approach for in-situ determination of the transverse magnetic anisotropy (TMA) of an individual molecule by electronic transport measurements, see Phys. Rev. B 91, 035442 (2015). We study a Fe4 single-molecule magnet (SMM) captured in a gateable junction, a unique tool for addressing the spin in different redox states of a molecule. We show that, due to mixing of the spin eigenstates of the SMM, the TMA significantly manifests itself in transport. We predict and experimentally observe the pronounced intensity modulation of the Coulomb peak amplitude with the magnetic field in the linear-response transport regime, from which the TMA parameter E can be estimated. Importantly, the method proposed here does not rely on the small induced tunnelling effects and, hence, works well at temperatures and electron tunnel broadenings by far exceeding the tunnel splittings and even E itself. We deduce that the TMA for a single Fe4 molecule captured in a junction is substantially larger than the bulk value. Work supported by the Polish Ministry of Science and Education as `Iuventus Plus' project (IP2014 030973) in years 2015-2016.

  13. Probing α -RuCl3 Beyond Magnetic Order: Effects of Temperature and Magnetic Field

    Science.gov (United States)

    Winter, Stephen M.; Riedl, Kira; Kaib, David; Coldea, Radu; Valentí, Roser

    2018-02-01

    Recent studies have brought α -RuCl3 to the forefront of experimental searches for materials realizing Kitaev spin-liquid physics. This material exhibits strongly anisotropic exchange interactions afforded by the spin-orbit coupling of the 4 d Ru centers. We investigate the dynamical response at finite temperature and magnetic field for a realistic model of the magnetic interactions in α -RuCl3 . These regimes are thought to host unconventional paramagnetic states that emerge from the suppression of magnetic order. Using exact diagonalization calculations of the quantum model complemented by semiclassical analysis, we find a very rich evolution of the spin dynamics as the applied field suppresses the zigzag order and stabilizes a quantum paramagnetic state that is adiabatically connected to the fully polarized state at high fields. At finite temperature, we observe large redistributions of spectral weight that can be attributed to the anisotropic frustration of the model. These results are compared to recent experiments and provide a road map for further studies of these regimes.

  14. Probing Ultrafast Electron Dynamics at Surfaces Using Soft X-Ray Transient Reflectivity Spectroscopy

    Science.gov (United States)

    Baker, L. Robert; Husek, Jakub; Biswas, Somnath; Cirri, Anthony

    The ability to probe electron dynamics with surface sensitivity on the ultrafast time scale is critical for understanding processes such as charge separation, injection, and surface trapping that mediate efficiency in catalytic and energy conversion materials. Toward this goal, we have developed a high harmonic generation (HHG) light source for femtosecond soft x-ray reflectivity. Using this light source we investigated the ultrafast carrier dynamics at the surface of single crystalline α-Fe2O3, polycrystalline α-Fe2O3, and the mixed metal oxide, CuFeO2. We have recently demonstrated that CuFeO2 in particular is a selective catalyst for photo-electrochemical CO2 reduction to acetate; however, the role of electronic structure and charge carrier dynamics in mediating catalytic selectivity has not been well understood. Soft x-ray reflectivity measurements probe the M2,3, edges of the 3d transition metals, which provide oxidation and spin state resolution with element specificity. In addition to chemical state specificity, these measurements are also surface sensitive, and by independently simulating the contributions of the real and imaginary components of the complex refractive index, we can differentiate between surface and sub-surface contributions to the excited state spectrum. Accordingly, this work demonstrates the ability to probe ultrafast carrier dynamics in catalytic materials with element and chemical state specificity and with surface sensitivity.

  15. A magnetic particle micro-trap for large trapping surfaces

    KAUST Repository

    Gooneratne, Chinthaka P.

    2012-01-08

    Manipulation of micron-size magnetic particles of the superparamagnetic type contributes significantly in many applications like controlling the antibody/antigen binding process in immunoassays. Specifically, more target biomolecules can be attached/tagged and analyzed since the three dimensional structure of the magnetic particles increases the surface to volume ratio. Additionally, such biomolecular-tagged magnetic particles can be easily manipulated by an external magnetic field due to their superparamagnetic behavior. Therefore, magnetic particle- based immunoassays are extensively applied in micro-flow cytometry. The design of a square-loop micro-trap as a magnetic particle manipulator as well as numerical and experimental analysis is presented. Experimental results showed that the micro-trap could successfully trap and concentrate magnetic particles from a large to a small area with a high spatial range.

  16. Metal-coated magnetic nanoparticles for surface enhanced Raman ...

    Indian Academy of Sciences (India)

    magnetic properties of these nanoparticles combined with SERS provide a wide range of applications. Keywords. Surface-enhanced Raman scattering; magnetic nanoparticles; core-shell nanostructure; bio-diagnosis. 1. Introduction. In recent years, plasmonic nanostructures exhibiting novel optical properties have attracted ...

  17. Surface structure of quark stars with magnetic fields

    Indian Academy of Sciences (India)

    We investigate the impact of magnetic fields on the electron distribution of the electrosphere of quark stars. For moderately strong magnetic fields of ∼ 1013 G, quantization effects are generally weak due to the large number density of electrons at surface, but can nevertheless affect the photon emission properties of quark ...

  18. Linked Min.B configuration inside high shear magnetic surface

    International Nuclear Information System (INIS)

    Ohasa, K.; Ikuta, K.

    1976-03-01

    Arrangement of the l = m baseball coils to form the toroidally linked Min.B configuration with large rotational transform is studied analytically and numerically. By an optimization the closed magnetic isobars are obtained inside the last closed magnetic surface having practical volume and high shear if l = 3 baseball coils are arranged. (auth.)

  19. The use of low energy alkali ion scattering as a probe of surface structure

    International Nuclear Information System (INIS)

    Overbury, S.H.

    1987-01-01

    An overview is given of the use of low energy ion scattering as a probe of surface structure with emphasis on work done using alkali ions. Various schemes for extracting structural information from the ion energy and angle distribution are discussed in therms of advantages and disadvantages of each. The scattering potential, which is the primary nonstructural parameter needed for analysis, is discussed in terms of recent experimental results. The structures of clean and reconstructed surfaces are discussed, with examples of measurements of layer relaxations on the Mo (111) surface and missing row reconstructions on the Au (110) and Pt (110) surfaces. Studies of adsorbate covered surfaces are presented with respect to location of the adsorbate and its effect on the structure of the underlying substrate. Finally, examples are given which demonstrate the sensitivity of ion scattering to surface defects and disordering on reconstructed Au (110) and Pt (110) surfaces and reconstructed Mo (111) surfaces, and to ordering of adsorbates on Mo

  20. Surface Magnetism of Cobalt Nanoislands Controlled by Atomic Hydrogen.

    Science.gov (United States)

    Park, Jewook; Park, Changwon; Yoon, Mina; Li, An-Ping

    2017-01-11

    Controlling the spin states of the surface and interface is key to spintronic applications of magnetic materials. Here, we report the evolution of surface magnetism of Co nanoislands on Cu(111) upon hydrogen adsorption and desorption with the hope of realizing reversible control of spin-dependent tunneling. Spin-polarized scanning tunneling microscopy reveals three types of hydrogen-induced surface superstructures, 1H-(2 × 2), 2H-(2 × 2), and 6H-(3 × 3), with increasing H coverage. The prominent magnetic surface states of Co, while being preserved at low H coverage, become suppressed as the H coverage level increases, which can then be recovered by H desorption. First-principles calculations reveal the origin of the observed magnetic surface states by capturing the asymmetry between the spin-polarized surface states and identify the role of hydrogen in controlling the magnetic states. Our study offers new insights into the chemical control of magnetism in low-dimensional systems.

  1. Ring-averaged ion velocity distribution function probe for laboratory magnetized plasma experiment.

    Science.gov (United States)

    Kawamori, Eiichirou; Chen, Jinting; Lin, Chiahsuan; Lee, Zongmau

    2017-10-01

    Ring-averaged velocity distribution function of ions at a fixed guiding center position is a fundamental quantity in the gyrokinetic plasma physics. We have developed a diagnostic tool for the ring averaged velocity distribution function of ions for laboratory plasma experiments, which is named as the ring-averaged ion distribution function probe (RIDFP). The RIDFP is a set of ion collectors for different velocities. It is designed to be immersed in magnetized plasmas and achieves momentum selection of incoming ions by the selection of the ion Larmor radii. To nullify the influence of the sheath potential surrounding the RIDFP on the orbits of the incoming ions, the electrostatic potential of the RIDFP body is automatically adjusted to coincide with the space potential of the target plasma with the use of an emissive probe and a voltage follower. The developed RIDFP successfully measured the equilibrium ring-averaged velocity distribution function of a laboratory magnetized plasma, which was in accordance with the Maxwellian distribution having an ion temperature of 0.2 eV.

  2. Ring-averaged ion velocity distribution function probe for laboratory magnetized plasma experiment

    Science.gov (United States)

    Kawamori, Eiichirou; Chen, Jinting; Lin, Chiahsuan; Lee, Zongmau

    2017-10-01

    Ring-averaged velocity distribution function of ions at a fixed guiding center position is a fundamental quantity in the gyrokinetic plasma physics. We have developed a diagnostic tool for the ring averaged velocity distribution function of ions for laboratory plasma experiments, which is named as the ring-averaged ion distribution function probe (RIDFP). The RIDFP is a set of ion collectors for different velocities. It is designed to be immersed in magnetized plasmas and achieves momentum selection of incoming ions by the selection of the ion Larmor radii. To nullify the influence of the sheath potential surrounding the RIDFP on the orbits of the incoming ions, the electrostatic potential of the RIDFP body is automatically adjusted to coincide with the space potential of the target plasma with the use of an emissive probe and a voltage follower. The developed RIDFP successfully measured the equilibrium ring-averaged velocity distribution function of a laboratory magnetized plasma, which was in accordance with the Maxwellian distribution having an ion temperature of 0.2 eV.

  3. Development of Magnetically Insulated Baffled Probe Cluster for Measurement of Energy Flux and Particle Flux in the Texas Helimak

    Science.gov (United States)

    Nogami, S. H.; Koepke, M.; Demidov, V.; Williams, C.; Gentle, K.

    2015-11-01

    Progress is reported in employing magnetically insulated baffled (MIB) probes in the Texas Helimak. Radial scans at the plasma edge of dc and ac space potential are presented. Like the Ball-Pen probe, the MIB probe shares the Langmuir probe simplicity and overcomes its shortcomings in the ability to make real-time measurements of plasma space potential, temperature, and energy/particle fluxes in magnetized plasma. By rotating the probe shaft to change the extent to which the baffle ``masks'' the probe collection area, the ratio between electron and ion probe current, and consequently the relative sensitivity of the floating-probe oscillations to space potential and electron/ion temperature, can be adjusted, thus allowing space potential fluctuations and electron/ion temperature fluctuations to be distinguished when measured at two different rotation angles. At the optimal rotation angle, the contribution of electron temperature and its fluctuations to the floating-potential measurement are eliminated and the space potential fluctuation phase is preserved. Support from DOE is gratefully acknowledged.

  4. High-Temperature Magnetism as a Probe for Structural and Compositional Uniformity in Ligand-Capped Magnetite Nanoparticles.

    Science.gov (United States)

    Kolen'ko, Yury V; Bañobre-López, Manuel; Rodríguez-Abreu, Carlos; Carbó-Argibay, Enrique; Deepak, Francis Leonard; Petrovykh, Dmitri Y; Cerqueira, M Fátima; Kamali, Saeed; Kovnir, Kirill; Shtansky, Dmitry V; Lebedev, Oleg I; Rivas, Jose

    2014-12-04

    To investigate magnetostructural relationships in colloidal magnetite (Fe 3 O 4 ) nanoparticles (NPs) at high temperature (300-900 K), we measured the temperature dependence of magnetization ( M ) of oleate-capped magnetite NPs ca. 20 nm in size. Magnetometry revealed an unusual irreversible high-temperature dependence of M for these NPs, with dip and loop features observed during heating-cooling cycles. Detailed characterizations of as-synthesized and annealed Fe 3 O 4 NPs as well as reference ligand-free Fe 3 O 4 NPs indicate that both types of features in M ( T ) are related to thermal decomposition of the capping ligands. The ligand decomposition upon the initial heating induces a reduction of Fe 3+ to Fe 2+ and the associated dip in M , leading to more structurally and compositionally uniform magnetite NPs. Having lost the protective ligands, the NPs continually sinter during subsequent heating cycles, resulting in divergent M curves featuring loops. The increase in M with sintering proceeds not only through elimination of a magnetically dead layer on the particle surface, as a result of a decrease in specific surface area with increasing size, but also through an uncommonly invoked effect resulting from a significant change in Fe 3+ /Fe 2+ ratio with heat treatment. The interpretation of irreversible features in M ( T ) indicates that reversible M ( T ) behavior, conversely, can be expected only for ligand-free, structurally and compositionally uniform magnetite NPs, suggesting a general applicability of high-temperature M ( T ) measurements as an analytical method for probing the structure and composition of magnetic nanomaterials.

  5. Surface spin tunneling and heat dissipation in magnetic nanoparticles

    Science.gov (United States)

    Palakkal, Jasnamol P.; Obula Reddy, Chinna; Paulose, Ajeesh P.; Sankar, Cheriyedath Raj

    2018-03-01

    Quantum superparamagnetic state is observed in ultra-fine magnetic particles, which is often experimentally identified by a significant hike in magnetization towards low temperatures much below the superparamagnetic blocking temperature. Here, we report experimentally observed surface spin relaxation at low temperatures in hydrated magnesium ferrite nanoparticles of size range of about 5 nm. We observed time dependent oscillatory magnetization of the sample below 2.5 K, which is attributed to surface spin tunneling. Interestingly, we observed heat dissipation during the process by using an external thermometer.

  6. Micro-four-point probes in a UHV scanning electron microscope for in-situ surface-conductivity measurements

    DEFF Research Database (Denmark)

    Shiraki, I.; Nagao, T.; Hasegawa, S.

    2000-01-01

    For in-situ measurements of surface conductivity in ultrahigh vacuum (UHV), we have installed micro-four-point probes (probe spacings down to 4 mum) in a UHV scanning electron microscope (SEM) combined with scanning reflection-high-energy electron diffraction (RHEED). With the aid of piezoactuators...... for precise positioning of the probes, local conductivity of selected surface domains of well-defined superstructures could be measured during SEM and RHEED observations. It was found that the surface sensitivity of the conductivity measurements was enhanced by reducing the probe spacing, enabling...

  7. Probing the switching state of a surface-mounted azobenzene derivative using femtosecond XUV photoemission

    Science.gov (United States)

    Grunau, Jan; Heinemann, Nils; Rohwer, Timm; Zargarani, Dordaneh; Kuhn, Sonja; Jung, Ullrich; Kipp, Lutz; Magnussen, Olaf; Herges, Rainer; Bauer, Michael

    2012-03-01

    Photoemission spectroscopy using femtosecond XUV light pulses is applied to probe the isomerization state of the molecular switch 3-(4-(4-hexyl-phenylazo)-phenoxy)-propane-1-thiol deposited by liquid phase self-assembly on Au(111). Spectral shifts of valence-electronic signatures that we associate with the carbon C2s orbital enable us to distinguish the trans and the cis isomerization state of the adsorbed molecules. These preliminary results envision the potential to probe reversible switching processes of surface-mounted molecules in real time by tracking the temporal evolution of the electronic and nuclear degrees of freedom in a femtosecond XUV photoemission experiment.

  8. Effect of magnetic polarity on surface roughness during magnetic field assisted EDM of tool steel

    Science.gov (United States)

    Efendee, A. M.; Saifuldin, M.; Gebremariam, MA; Azhari, A.

    2018-04-01

    Electrical discharge machining (EDM) is one of the non-traditional machining techniques where the process offers wide range of parameters manipulation and machining applications. However, surface roughness, material removal rate, electrode wear and operation costs were among the topmost issue within this technique. Alteration of magnetic device around machining area offers exciting output to be investigated and the effects of magnetic polarity on EDM remain unacquainted. The aim of this research is to investigate the effect of magnetic polarity on surface roughness during magnetic field assisted electrical discharge machining (MFAEDM) on tool steel material (AISI 420 mod.) using graphite electrode. A Magnet with a force of 18 Tesla was applied to the EDM process at selected parameters. The sparks under magnetic field assisted EDM produced better surface finish than the normal conventional EDM process. At the presence of high magnetic field, the spark produced was squeezed and discharge craters generated on the machined surface was tiny and shallow. Correct magnetic polarity combination of MFAEDM process is highly useful to attain a high efficiency machining and improved quality of surface finish to meet the demand of modern industrial applications.

  9. Comparative measurements of plasma potential with ball-pen and Langmuir probe in low-temperature magnetized plasma

    Science.gov (United States)

    Zanáška, M.; Adámek, J.; Peterka, M.; Kudrna, P.; Tichý, M.

    2015-03-01

    The ball-pen probe (BPP) is used for direct plasma potential measurements in magnetized plasma. The probe can adjust the ratio of the electron and ion saturation currents Isat-/Isat+ to be close to one and therefore its I-V characteristic becomes nearly symmetric. If this is achieved, the floating potential of the BPP is close to the plasma potential. Because of its rather simple construction, it offers an attractive probe for measurements in magnetized plasma. Comparative measurements of plasma potential by BPPs of different dimensions as well as one Langmuir probe (LP) in an argon discharge plasma of a cylindrical magnetron were performed at various experimental conditions. An additional comparison by an emissive probe was also performed. All these types of probes provide similar values of plasma potential in a wide range of plasma parameters. Our results for three different BPP dimensions indicate that the BPP can be operated in a cylindrical magnetron DC argon discharge if the value of the ratio of the magnetic field and neutral gas pressure, B/p, is greater than approximately 10 mT/Pa.

  10. Probing structure-property relationships in perpendicularly magnetized Fe/Cu(001) using MXLD and XPD

    Energy Technology Data Exchange (ETDEWEB)

    Cummins, T.R.; Waddill, G.D. [Univ. of Missouri, Rolla, MO (United States); Goodman, K.W. [Lawrence Berkeley National Lab., CA (United States)] [and others

    1997-04-01

    Magnetic X-ray Linear Dichroism (MXLD) in Photoelectron Spectroscopy and X-Ray Photoelectron Diffraction (XPD) of the Fe 3p core level have been used to probe the magnetic structure-property relationships of perpendicularly magnetized Fe/Cu(001), in an element-specific fashion. A strong MEXLD effect was observed in the high resolution photoelectron spectroscopy of the Fe 3p at {open_quotes}normal{close_quotes} emission and was used to follow the loss of perpendicular ferromagnetic ordering as the temperature was raised toward room temperature. In parallel with this, {open_quotes}Forward Focussing{close_quotes} in XPD was used as a direct measure of geometric structure in the overlayer. These results and the implications of their correlation will be discussed. Additionally, an investigation of the effect of Mn doping of the Fe/Cu(001) will be described. These measurements were performed at the Spectromicroscopy Facility (Beamline 7.0.1) of the Advanced Light Source.

  11. Advances in Langmuir probe diagnostics of the plasma potential and electron-energy distribution function in magnetized plasma

    Czech Academy of Sciences Publication Activity Database

    Popov, Tsv.K.; Dimitrova, Miglena; Ivanova, P.; Kovačič, J.; Gyergyek, T.; Dejarnac, Renaud; Stöckel, Jan; Pedrosa, M.A.; López-Bruna, D.; Hidalgo, C.

    2016-01-01

    Roč. 25, č. 3 (2016), č. článku 033001. ISSN 0963-0252 R&D Projects: GA ČR(CZ) GAP205/12/2327; GA MŠk(CZ) LM2011021 EU Projects: European Commission(XE) 633053 - EUROfusion Institutional support: RVO:61389021 Keywords : COMPASS tokamak * Langmuir probes * magnetized plasma * second-derivative probe techniques * first-derivative probe techniques * plasma potential * EEDF Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 3.302, year: 2016 http://iopscience.iop.org/article/10.1088/0963-0252/25/3/033001/meta

  12. A surface plasmon resonance probe without optical fibers as a portable sensing device

    International Nuclear Information System (INIS)

    Akimoto, Takuo; Wada, Syunsuke; Karube, Isao

    2008-01-01

    A surface plasmon resonance (SPR) sensor integrating a small sensor probe, a laser emission diode, a photo detector, and a polarizer was developed as a portable sensing device. The sensor probe was made with a glass cylinder, 50 mm long and 1.5 mm in diameter, that was connected directly to a beam splitter without optical fibers. The SPR spectrum obtained with this probe system showed a 10% reflectivity minimum at 690 nm. Shifts of the SPR spectrum induced by refractive index (RI) changes in the sample were measured by detecting the reflection light intensity at 670 nm. When the sensitivity was compared using a BIAcore TM SPR instrument, the lowest sensor response of 1 mV observed with the SPR probe system coincided with 1.4 x 10 -6 of the RI changes. The RI resolution of the SPR probe was estimated with experimentally evaluated noise on the signal, and, consequently, it was concluded that the RI resolution was 1.2 x 10 -5 . Moreover, immunoreaction was demonstrated with adsorbed bovine serum albumin (BSA) and anti-BSA antibody as an analyte. As a result, 50 ng mL -1 of the lower detection limit was estimated

  13. Magnetic flux surface measurements at the Wendelstein 7-X stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Otte, Matthias; Andreeva, Tamara; Biedermann, Christoph; Bozhenkov, Sergey; Geiger, Joachim; Sunn Pedersen, Thomas [Max-Planck-Institut fuer Plasmaphysik, Greifswald (Germany); Lazerson, Samuel [Princeton Plasma Physics Laboratory, Princeton (United States)

    2016-07-01

    Recently the first plasma operation phase of the Wendelstein 7-X stellarator has been started at IPP Greifswald. Wendelstein 7-X is an optimized stellarator with a complex superconducting magnet system consisting of 50 non-planar and 20 planar field coils and further 10 normal conducting control and 5 trim coils. The magnetic confinement and hence the expected plasma performance are decisively determined by the properties of the magnet system, especially by the existence and quality of the magnetic flux surfaces. Even small error fields may result in significant changes of the flux surface topology. Therefore, measurements of the vacuum magnetic flux surfaces have been performed before plasma operation. The first experimental results confirm the existence and quality of the flux surfaces to the full extend from low field up to the nominal field strength of B=2.5T. This includes the dedicated magnetic limiter configuration that is exclusively used for the first plasma operation. Furthermore, the measurements are indicating that the intrinsic error fields are within the tolerable range and can be controlled utilizing the trim coils as expected.

  14. Near-surface nanoscale InAs Hall cross sensitivity to localized magnetic and electric fields.

    Science.gov (United States)

    Folks, L; Troup, A S; Boone, T D; Katine, J A; Nishioka, M; Grobis, M; Sullivan, G J; Ikhlassi, A; Field, M; Gurney, B A

    2009-06-24

    We have measured the room temperature response of nanoscale semiconductor Hall crosses to local applied magnetic fields under various local electric gate conditions using scanning probe microscopy. Near-surface quantum wells of AlSb/InAs/AlSb, located just 5 nm from the heterostructure surface, allow very high sensitivity to localized electric and magnetic fields applied near the device surfaces. The Hall crosses have critical dimensions of 400 and 100 nm, while the mean free path of the carriers is about 160 nm; hence the devices nominally span the transition from diffusive to quasi-ballistic transport. With certain small gate voltages (V(g)) the devices of both sizes are strongly responsive to the local magnetic field at the center of the cross, and the results are well described using finite element modeling. At high V(g), the response to local magnetic fields is greatly distorted by strong electric fields applied near the cross corners. However we observe no change in behavior with the size of the device.

  15. Magnetic Fields above the Surface of aSuperconductor with Internal Magnetism

    Energy Technology Data Exchange (ETDEWEB)

    Bluhm, Hendrik; /Stanford U., Phys. Dept. /SLAC, SSRl

    2007-06-26

    The author presents a method for calculating the magnetic fields near a planar surface of a superconductor with a given intrinsic magnetization in the London limit. He computes solutions for various magnetic domain boundary configurations and derives relations between the spectral densities of the magnetization and the resulting field in the vacuum half space, which are useful if the magnetization can be considered as a statistical quantity and its features are too small to be resolved individually. The results are useful for analyzing and designing magnetic scanning experiments. Application to existing data from such experiments on Sr{sub 2}RuO{sub 4} show that a domain wall would have been detectable, but the magnetic field of randomly oriented small domains and small defects may have been smaller than the experimental noise level.

  16. Mercury's Surface Magnetic Field Determined from Proton-Reflection Magnetometry

    Science.gov (United States)

    Winslow, Reka M.; Johnson, Catherine L.; Anderson, Brian J.; Gershman, Daniel J.; Raines, Jim M.; Lillis, Robert J.; Korth, Haje; Slavin, James A.; Solomon, Sean C.; Zurbuchen, Thomas H.; hide

    2014-01-01

    Solar wind protons observed by the MESSENGER spacecraft in orbit about Mercury exhibit signatures of precipitation loss to Mercury's surface. We apply proton-reflection magnetometry to sense Mercury's surface magnetic field intensity in the planet's northern and southern hemispheres. The results are consistent with a dipole field offset to the north and show that the technique may be used to resolve regional-scale fields at the surface. The proton loss cones indicate persistent ion precipitation to the surface in the northern magnetospheric cusp region and in the southern hemisphere at low nightside latitudes. The latter observation implies that most of the surface in Mercury's southern hemisphere is continuously bombarded by plasma, in contrast with the premise that the global magnetic field largely protects the planetary surface from the solar wind.

  17. Surface mapping of magnetic hot stars. Theories versus observations

    Science.gov (United States)

    Kochukhov, O.

    2018-01-01

    This review summarises results of recent magnetic and chemical abundance surface mapping studies of early-type stars. We discuss main trends uncovered by observational investigations and consider reliability of spectropolarimetric inversion techniques used to infer these results. A critical assessment of theoretical attempts to interpret empirical magnetic and chemical maps in the framework of, respectively, the fossil field and atomic diffusion theories is also presented. This confrontation of theory and observations demonstrates that 3D MHD models of fossil field relaxation are successful in matching the observed range of surface magnetic field geometries. At the same time, even the most recent time-dependent atomic diffusion calculations fail to reproduce diverse horizontal abundance distributions found in real magnetic hot stars.

  18. RADIO SYNCHROTRON FLUCTUATION STATISTICS AS A PROBE OF MAGNETIZED INTERSTELLAR TURBULENCE

    International Nuclear Information System (INIS)

    Herron, C. A.; Gaensler, B. M.; Burkhart, Blakesley; Lazarian, A.; McClure-Griffiths, N. M.

    2016-01-01

    We investigate how observations of synchrotron intensity fluctuations can be used to probe the sonic and Alfvénic Mach numbers of interstellar turbulence, based on mock observations performed on simulations of magnetohydrodynamic turbulence. We find that the structure function slope and a diagnostic of anisotropy that we call the integrated quadrupole ratio modulus both depend on the Alfvénic Mach number. However, these statistics also depend on the orientation of the mean magnetic field in the synchrotron emitting region relative to our line of sight, and this creates a degeneracy that cannot be broken by observations of synchrotron intensity alone. We conclude that the polarization of synchrotron emission could be analyzed to break this degeneracy, and suggest that this will be possible with the Square Kilometre Array.

  19. RADIO SYNCHROTRON FLUCTUATION STATISTICS AS A PROBE OF MAGNETIZED INTERSTELLAR TURBULENCE

    Energy Technology Data Exchange (ETDEWEB)

    Herron, C. A.; Gaensler, B. M. [Sydney Institute for Astronomy, School of Physics, University of Sydney, New South Wales 2006 (Australia); Burkhart, Blakesley [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA (United States); Lazarian, A. [Astronomy Department, University of Wisconsin, Madison, 475 N. Charter Street, WI 53711 (United States); McClure-Griffiths, N. M., E-mail: C.Herron@physics.usyd.edu.au [Research School of Astronomy and Astrophysics, The Australian National University, Canberra, ACT 2611 (Australia)

    2016-05-01

    We investigate how observations of synchrotron intensity fluctuations can be used to probe the sonic and Alfvénic Mach numbers of interstellar turbulence, based on mock observations performed on simulations of magnetohydrodynamic turbulence. We find that the structure function slope and a diagnostic of anisotropy that we call the integrated quadrupole ratio modulus both depend on the Alfvénic Mach number. However, these statistics also depend on the orientation of the mean magnetic field in the synchrotron emitting region relative to our line of sight, and this creates a degeneracy that cannot be broken by observations of synchrotron intensity alone. We conclude that the polarization of synchrotron emission could be analyzed to break this degeneracy, and suggest that this will be possible with the Square Kilometre Array.

  20. Probing the Intergalactic Magnetic Field with the Anisotropy of the Extragalactic Gamma-ray Background

    Science.gov (United States)

    Venters, T. M.; Pavlidou, V.

    2013-01-01

    The intergalactic magnetic field (IGMF) may leave an imprint on the angular anisotropy of the extragalactic gamma-ray background through its effect on electromagnetic cascades triggered by interactions between very high energy photons and the extragalactic background light. A strong IGMF will deflect secondary particles produced in these cascades and will thus tend to isotropize lower energy cascade photons, thereby inducing a modulation in the anisotropy energy spectrum of the gamma-ray background. Here we present a simple, proof-of-concept calculation of the magnitude of this effect and demonstrate that current Fermi data already seem to prefer nonnegligible IGMF values. The anisotropy energy spectrum of the Fermi gamma-ray background could thus be used as a probe of the IGMF strength.

  1. Surface magnetism of exfoliated α-Co hydroxide nanosheets

    Science.gov (United States)

    Honda, Zentaro; Anai, Katsuki; Hagiwara, Masayuki; Kida, Takanori; Okutani, Akira; Sakai, Masamichi; Fukuda, Takeshi; Kamata, Norihiko

    2017-08-01

    α-Co hydroxide nanosheets have been synthesized and their magnetic properties were investigated. By using a soft chemical exfoliation technique, exfoliated α-Co hydroxide nanosheets, typically with lateral dimensions of few 100 nm, were obtained in a colloidal suspension. The magnetic responses of a sample consisting of a colloidal suspension of the nanosheets indicates a ferromagnetic phase transition occurs at TC=37.8 K. The magnetization possesses a linear temperature dependence at low temperatures below TC. In addition to this observation, the magnetization is proportional to (1-T/TC)β with β=0.8±0.1 near TC, which imply that the surface magnetism dominates in the exfoliated α-Co hydroxide nanosheets.

  2. Magnetic Nanoparticles: Surface Effects and Properties Related to Biomedicine Applications

    OpenAIRE

    Issa, Bashar; Obaidat, Ihab M.; Albiss, Borhan A.; Haik, Yousef

    2013-01-01

    Due to finite size effects, such as the high surface-to-volume ratio and different crystal structures, magnetic nanoparticles are found to exhibit interesting and considerably different magnetic properties than those found in their corresponding bulk materials. These nanoparticles can be synthesized in several ways (e.g., chemical and physical) with controllable sizes enabling their comparison to biological organisms from cells (10–100 μm), viruses, genes, down to proteins (3–50 nm). The opti...

  3. Evaluation of surface decarburization depth by magnetic Barkhausen noise technique

    Czech Academy of Sciences Publication Activity Database

    Stupakov, Oleksandr; Perevertov, Oleksiy; Tomáš, Ivan; Skrbek, B.

    2011-01-01

    Roč. 323, č. 12 (2011), s. 1692-1697 ISSN 0304-8853 R&D Projects: GA ČR GA101/09/1323; GA ČR GP102/09/P108 Grant - others:AVČR(CZ) M100100906 Institutional research plan: CEZ:AV0Z10100520 Keywords : Barkhausen noise * steel surface decarburization * residual stress * magnetic non-destructive testing Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.780, year: 2011

  4. A probe for Eddy current inspection devices

    International Nuclear Information System (INIS)

    1974-01-01

    The invention relates to a surface probe for Eddy current inspection devices. According to the invention, said probe comprises two magnetic core windings, with their axes in parallel relationship and at right angles to the surface of the part to be inspected. This can be applied to the nondestructive inspection of reactor components [fr

  5. Study of Binding between Protein A and Immunoglobulin G Using a Surface Tension Probe

    OpenAIRE

    Yang, L.; Biswas, M. E.; Chen, P.

    2003-01-01

    Molecular interactions and binding are one of the most important and fundamental properties in the study of biochemical and biomedical systems. The understanding of such interactions and binding among biomolecules forms the basis for the design and processing of many biotechnological applications, such as bioseparation and immunoadsorption. In this study, we present a novel method to probe molecular interactions and binding based on surface tension measurement. This method complements convent...

  6. Friction as a probe of surface properties of a polymer glass

    OpenAIRE

    Bureau, Lionel

    2007-01-01

    We probe the temperature dependence of friction at the interface between a glassy poly(methylmethacrylate) lens and a flat substrate coated with a methyl-terminated self-assembled monolayer. The monolayer exhibits density defects which act as pinning sites for the polymer chains. We show that the shear response of such an interface supports the existence, at the surface of the glassy polymer, of a nanometer-thick layer of mobile chains. Friction can be ascribed to the interplay between viscou...

  7. In situ surface reduction of a NiO-YSZ-alumina composite using scanning probe microscopy

    DEFF Research Database (Denmark)

    Hansen, Karin Vels; Jacobsen, Torben; Thydén, Karl Tor Sune

    2014-01-01

    In situ surface reductions of NiO-YSZ-Al2O3 composites into Ni-YSZ-Al2O3 cermets were carried out at 312–525 °C in a controlled atmosphere high-temperature scanning probe microscope (CAHT-SPM) in dry and humidified 9 % H2 in N2. The reduction of NiO was followed by contact mode scanning of topogr...

  8. Protein surface topology-probing by selective chemical modification and mass spectrometric peptide mapping.

    OpenAIRE

    Suckau, D; Mak, M; Przybylski, M

    1992-01-01

    Aminoacetylation of lysine residues and the modification of arginine by 1,2-cyclohexanedione to N7,N8-(dihydroxy-1,2-cyclohexylidene)arginine were used for probing the surface topology of hen-eggwhite lysozyme as a model protein. The molecular identification of lysine and arginine modification sites was provided by molecular weight determinations of modified and unmodified tryptic peptide mixtures (peptide mapping) using 252Cf plasma desorption mass spectrometry. At conditions of limited chem...

  9. Synergistic structures from magnetic freeze casting with surface magnetized alumina particles and platelets.

    Science.gov (United States)

    Frank, Michael B; Hei Siu, Sze; Karandikar, Keyur; Liu, Chin-Hung; Naleway, Steven E; Porter, Michael M; Graeve, Olivia A; McKittrick, Joanna

    2017-12-01

    Magnetic freeze casting utilizes the freezing of water, a low magnetic field and surface magnetized materials to make multi-axis strengthened porous scaffolds. A much greater magnetic moment was measured for larger magnetized alumina platelets compared with smaller particles, which indicated that more platelet aggregation occurred within slurries. This led to more lamellar wall alignment along the magnetic field direction during magnetic freeze casting at 75 mT. Slurries with varying ratios of magnetized particles to platelets (0:1, 1:3, 1:1, 3:1, 7:1, 1:0) produced porous scaffolds with different structural features and degrees of lamellar wall alignment. The greatest mechanical enhancement in the magnetic field direction was identified in the synergistic condition with the highest particle to platelet ratio (7:1). Magnetic freeze casting with varying ratios of magnetized anisotropic and isotropic alumina provided insights about how heterogeneous morphologies aggregate within lamellar walls that impact mechanical properties. Fabrication of strengthened scaffolds with multi-axis aligned porosity was achieved without introducing different solid materials, freezing agents or additives. Resemblance of 7:1 particle to platelet scaffold microstructure to wood light-frame house construction is framed in the context of assembly inspiration being derived from both natural and synthetic sources. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Surfaces of colloidal PbSe nanocrystals probed by thin-film positron annihilation spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Chai, L.; Schut, H.; Schaarenburg, L. C. van; Eijt, S. W. H., E-mail: S.W.H.Eijt@tudelft.nl [Department of Radiation, Radionuclides and Reactors, Faculty of Applied Sciences, Delft University of Technology, Mekelweg 15, NL-2629 JB Delft (Netherlands); Al-Sawai, W.; Barbiellini, B.; Bansil, A. [Physics Department, Northeastern University, Boston, Massachusetts 02115 (United States); Gao, Y. [Department of Chemical Engineering, Faculty of Applied Sciences, Delft University of Technology, Julianalaan 136, NL-2628 BL Delft (Netherlands); Kavli Institute of Nanoscience, Faculty of Applied Sciences, Delft University of Technology, Lorentzweg 1, NL-2628 CJ Delft (Netherlands); Houtepen, A. J. [Department of Chemical Engineering, Faculty of Applied Sciences, Delft University of Technology, Julianalaan 136, NL-2628 BL Delft (Netherlands); Mijnarends, P. E. [Department of Radiation, Radionuclides and Reactors, Faculty of Applied Sciences, Delft University of Technology, Mekelweg 15, NL-2629 JB Delft (Netherlands); Physics Department, Northeastern University, Boston, Massachusetts 02115 (United States); Huis, M. A. van [Kavli Institute of Nanoscience, Faculty of Applied Sciences, Delft University of Technology, Lorentzweg 1, NL-2628 CJ Delft (Netherlands); Ravelli, L.; Egger, W. [Institut für Angewandte Physik und Messtechnik, Universität der Bundeswehr München, Werner-Heisenberg-Weg 39, D-85579 Neubiberg (Germany); Kaprzyk, S. [Physics Department, Northeastern University, Boston, Massachusetts 02115 (United States); Academy of Mining and Metallurgy AGH, PL-30059 Kraków (Poland)

    2013-08-01

    Positron annihilation lifetime spectroscopy and positron-electron momentum density (PEMD) studies on multilayers of PbSe nanocrystals (NCs), supported by transmission electron microscopy, show that positrons are strongly trapped at NC surfaces, where they provide insight into the surface composition and electronic structure of PbSe NCs. Our analysis indicates abundant annihilation of positrons with Se electrons at the NC surfaces and with O electrons of the oleic ligands bound to Pb ad-atoms at the NC surfaces, which demonstrates that positrons can be used as a sensitive probe to investigate the surface physics and chemistry of nanocrystals inside multilayers. Ab initio electronic structure calculations provide detailed insight in the valence and semi-core electron contributions to the positron-electron momentum density of PbSe. Both lifetime and PEMD are found to correlate with changes in the particle morphology characteristic of partial ligand removal.

  11. Surfaces of colloidal PbSe nanocrystals probed by thin-film positron annihilation spectroscopy

    Directory of Open Access Journals (Sweden)

    L. Chai

    2013-08-01

    Full Text Available Positron annihilation lifetime spectroscopy and positron-electron momentum density (PEMD studies on multilayers of PbSe nanocrystals (NCs, supported by transmission electron microscopy, show that positrons are strongly trapped at NC surfaces, where they provide insight into the surface composition and electronic structure of PbSe NCs. Our analysis indicates abundant annihilation of positrons with Se electrons at the NC surfaces and with O electrons of the oleic ligands bound to Pb ad-atoms at the NC surfaces, which demonstrates that positrons can be used as a sensitive probe to investigate the surface physics and chemistry of nanocrystals inside multilayers. Ab initio electronic structure calculations provide detailed insight in the valence and semi-core electron contributions to the positron-electron momentum density of PbSe. Both lifetime and PEMD are found to correlate with changes in the particle morphology characteristic of partial ligand removal.

  12. Developing an optical chopper-modulated capacitive probe for measuring surface charge.

    Science.gov (United States)

    Ugolini, D; McKinney, R; Harry, G M

    2007-04-01

    Gravitational-wave observatories such as Laser Interferometer Gravitational-Wave Observatory (LIGO) use suspended optics in a Michelson interferometer configuration to measure strains in space between 10 Hz and 3 kHz. One potential noise source in this frequency range is the buildup and motion of surface charge on the optics, which can generate fluctuating electric fields, interfere with position control, and reduce reflectance by attracting dust to the optical surface. We have developed a capacitive probe to measure the magnitude and relaxation time of surface charge deposited on smaller test optics in high vacuum ( approximately 10(-5) Torr). Our device modulates capacitance with a tuning-fork optical chopper between probe and sample, chosen for vacuum compatibility and minimal cost. We have found that the probe has a resolution of (3.5+/-0.5)x10(5) e(-)cm(2) in air, on the order of charging levels that could contribute noise to Advanced LIGO, and sufficient for measuring relaxation times on test optics.

  13. Methicillin-Resistant Bacteria Inhabiting Surface Waters Monitored by mecA-Targeted Oligonucleotide Probes.

    Science.gov (United States)

    Seyedmonir, Elnaz; Yilmaz, Fadime; Icgen, Bulent

    2016-08-01

    Part of a 20-60 kb staphylococcal chromosome cassette called mecA encodes low-affinity penicillin-binding protein PBP2a and causes methicillin resistance. Among all methicillin-resistant bacteria, methicillin-resistant Staphylococcus aureus is a major pathogen and main concern worldwide. Although the origin of the mecA is not very well-defined, mecA homologues are also ubiquitous in methicillin-resistant non-staphylococcal bacteria. Due to the dissemination of methicillin resistance through the transmission of mecA gene among staphylococcal and non-staphylococcal bacteria inhabiting surface waters, there is a need to monitor mecA gene in these waters for public health safety. Therefore, this study aimed at monitoring mecA harboring bacteria inhabiting surface waters by using fluorescently labelled mecA-targeted oligonucleotide probes. Under the hybridization conditions of 55 % formamide and 0.020 M NaCl at 46°C, the oligonucleotide probe used in the study showed high hybridization stringency to the mecA gene targeted. The strong linear relationships observed between the signal intensity and the target gene were used to assess the population dynamics of mecA harboring isolates over a 2-year-period. The results indicated that mecA-targeted oligonucleotide probes can be effectively used for in situ monitoring of methicillin resistant isolates inhabiting surface waters.

  14. Fourier decomposition of segmented magnets with radial magnetization in surface-mounted PM machines

    Science.gov (United States)

    Tiang, Tow Leong; Ishak, Dahaman; Lim, Chee Peng

    2017-11-01

    This paper presents a generic field model of radial magnetization (RM) pattern produced by multiple segmented magnets per rotor pole in surface-mounted permanent magnet (PM) machines. The magnetization vectors from either odd- or even-number of magnet blocks per pole are described. Fourier decomposition is first employed to derive the field model, and later integrated with the exact 2D analytical subdomain method to predict the magnetic field distributions and other motor global quantities. For the assessment purpose, a 12-slot/8-pole surface-mounted PM motor with two segmented magnets per pole is investigated by using the proposed field model. The electromagnetic performances of the PM machines are intensively predicted by the proposed magnet field model which include the magnetic field distributions, airgap flux density, phase back-EMF, cogging torque, and output torque during either open-circuit or on-load operating conditions. The analytical results are evaluated and compared with those obtained from both 2D and 3D finite element analyses (FEA) where an excellent agreement has been achieved.

  15. The role of MFM signal in mark size measurement in probe-based magnetic recording on CoNi/Pt multilayers

    NARCIS (Netherlands)

    Zhang, Li; Bain, James A.; Zhu, Jian-Gang; Abelmann, Leon; Onoue, T.

    2007-01-01

    A method of heat-assisted magnetic recording (HAMR) potentially suitable for probe-based storage systems is characterized. Magnetic marks were formed by a scanning tunneling microscopy (STM)-based thermal magnetic mechanism on a perpendicular CoNi/Pt multilayered film. Magnetic force microscopy

  16. Probing surface tension additivity on chemically heterogeneous surfaces by a molecular approach.

    Science.gov (United States)

    Wang, Jihang; Bratko, Dusan; Luzar, Alenka

    2011-04-19

    Surface free energy of a chemically heterogeneous surface is often treated as an approximately additive quantity through the Cassie equation [Cassie ABD (1948) Discuss Faraday Soc 3:11-16]. However, deviations from additivity are common, and molecular interpretations are still lacking. We use molecular simulations to measure the microscopic analogue of contact angle, Θ(c), of aqueous nanodrops on heterogeneous synthetic and natural surfaces as a function of surface composition. The synthetic surfaces are layers of graphene functionalized with prototypical nonpolar and polar head group: methyl, amino, and nitrile. We demonstrate positive as well as negative deviations from the linear additivity. We show the deviations reflect the uneven exposure of mixture components to the solvent and the linear relation is recovered if fractions of solvent-accessible surface are used as the measure of composition. As the spatial variations in polarity become of larger amplitude, the linear relation can no longer be obtained. Protein surfaces represent such natural patterned surfaces, also characterized by larger patches and roughness. Our calculations reveal strong deviations from linear additivity on a prototypical surface comprising surface fragments of melittin dimer. The deviations reflect the disproportionately strong influence of isolated polar patches, preferential wetting, and changes in the position of the liquid interface above hydrophobic patches. Because solvent-induced contribution to the free energy of surface association grows as cos Θ(c), deviations of cos Θ(c) from the linear relation directly reflect nonadditive adhesive energies of biosurfaces.

  17. Probing the spectral density of the surface electromagnetic fields through scattering of waveguide photons.

    Science.gov (United States)

    Chen, Guang-Yin

    2016-02-10

    The spectral density of the metal-surface electromagnetic fields will be strongly modified in the presence of a closely-spaced quantum emitter. In this work, we propose a feasible way to probe the changes of the spectral density through the scattering of the waveguide photon incident on the quantum emitter. The variances of the lineshape in the transmission spectra indicate the coherent interaction between the emitter and the pseudomode resulting from all the surface electromagnetic modes. We further investigate the quantum coherence between the emitter and the pseudomode of the metal-dielectric interface.

  18. Evolution of magnetism on a curved nano-surface.

    Science.gov (United States)

    Merkel, D G; Bessas, D; Zolnai, Z; Rüffer, R; Chumakov, A I; Paddubrouskaya, H; Van Haesendonck, C; Nagy, N; Tóth, A L; Deák, A

    2015-08-14

    To design custom magnetic nanostructures, it is indispensable to acquire precise knowledge about the systems in the nanoscale range where the magnetism forms. In this paper we present the effect of a curved surface on the evolution of magnetism in ultrathin iron films. Nominally 70 Å thick iron films were deposited in 9 steps on 3 different types of templates: (a) a monolayer of silica spheres with 25 nm diameter, (b) a monolayer of silica spheres with 400 nm diameter and (c) for comparison a flat silicon substrate. In situ iron evaporation took place in an ultrahigh vacuum chamber using the molecular beam epitaxy technique. After the evaporation steps, time differential nuclear forward scattering spectra, grazing incidence small angle X-ray scattering images and X-ray reflectivity curves were recorded. In order to reconstruct and visualize the magnetic moment configuration in the iron cap formed on top of the silica spheres, micromagnetic simulations were performed for all iron thicknesses. We found a great influence of the template topography on the onset of magnetism and on the developed magnetic nanostructure. We observed an individual magnetic behaviour for the 400 nm spheres which was modelled by vortex formation and a collective magnetic structure for the 25 nm spheres where magnetic domains spread over several particles. Depth selective nuclear forward scattering measurements showed that the formation of magnetism begins at the top region of the 400 nm spheres in contrast to the 25 nm particles where the magnetism first appears in the region where the spheres are in contact with each other.

  19. Using fluorine nuclear magnetic resonance to probe the interaction of membrane-active peptides with the lipid bilayer.

    Science.gov (United States)

    Buer, Benjamin C; Chugh, Jeetender; Al-Hashimi, Hashim M; Marsh, E Neil G

    2010-07-13

    A variety of biologically active peptides exert their function through direct interactions with the lipid membrane of the cell. These surface interactions are generally transient and highly dynamic, making them hard to study. Here we have examined the feasibility of using solution phase (19)F nuclear magnetic resonance (NMR) to study peptide-membrane interactions. Using the antimicrobial peptide MSI-78 as a model system, we demonstrate that peptide binding to either small unilamellar vesicles (SUVs) or bicelles can readily be detected by simple one-dimensional (19)F NMR experiments with peptides labeled with l-4,4,4-trifluoroethylglycine. The (19)F chemical shift associated with the peptide-membrane complex is sensitive both to the position of the trifluoromethyl reporter group (whether in the hydrophobic face or positively charged face of the amphipathic peptide) and to the curvature of the lipid bilayer (whether the peptide is bound to SUVs or bicelles). (19)F spin echo experiments using the Carr-Purcell-Meiboom-Gill pulse sequence were used to measure the transverse relaxation (T(2)) of the nucleus and thereby examine the local mobility of the MSI-78 analogues bound to bicelles. The fluorine probe positioned in the hydrophobic face of the peptide relaxes at a rate that correlates with the tumbling of the bicelle, suggesting that it is relatively immobile, whereas the probe at the positively charged face relaxes more slowly, indicating this position is much more dynamic. These results are in accord with structural models of MSI-78 bound to lipids and point to the feasibility of using fluorine-labeled peptides to monitor peptide-membrane interactions in living cells.

  20. From surfaces to magnetic properties: special section dedicated to Juan Rojo

    Science.gov (United States)

    Mascaraque, A.; Rodríguez de la Fuente, O.; González-Barrio, Miguel A.

    2013-12-01

    Surface physics and magnetism, in particular the connection between surface defects, reduced dimensionality or size, crystal structure, electronic density of states and the mechanical and magnetic properties of solids, were always at the core of Juan Rojo's scientific interest and output. Both fields seem to meet at the nanoscale, a privileged playing field which is ideal for testing theoretical concepts, exploring new physics or probing a wealth of new, stunning and unheard-of applications. Upon reducing size or dimensionality, either in bulk systems or in thin films, surfaces and surface effects are telling. Thus, for instance, an ultra-thin coating can make nanoparticles of non-magnetic materials exhibit magnetic behaviour; or atomic steps can modify the local mechanical properties of a metallic single crystal. In this special section there are eight invited papers by disciples and close collaborators of Juan Rojo, that cover an ample spectrum of the above mentioned topics. The first paper, by Palacio et al, investigates the temperature and oxygen partial pressure conditions for FeO mono- and bi-layer growth on Ru(0001). The following paper, by Cortés-Gil et al, reports on the dramatic change in the electric resistivity of the manganite perovskite (La0.5Ca0.5)z MnO3 as a function of Ca content, an effect related to the removal of a charge-ordered state and a magnetic transition. Baeza et al study biomaterials for bone cancer treatment and skeletal reinforcing, as well as targeted magnetic nanoparticles used for intracell hyperthermia in cancer therapies. In the following paper, Marcano et al, assisted by a multi-technique approach, revisit the extraordinarily rich magnetic phase diagram of the Kondo system CeNi1- x Cux down to 100 mK temperatures. The magnetic field dependence of the martensitic transition temperature of the meta-magnetic shape memory alloy Ni50Mn34.5In15.5 in a crystalline and amorphous phase, in fields up to 13 T, is the subject of the paper

  1. Clay mineralogy and magnetic susceptibility of Oxisols in geomorphic surfaces

    Directory of Open Access Journals (Sweden)

    Livia Arantes Camargo

    2014-06-01

    Full Text Available Studies analyzing the variability of clay minerals and magnetic susceptibility provide data for the delineation of site-specific management areas since many of their attributes are important to agronomy and the environment. This study aimed to evaluate the spatial variability of clay minerals, magnetic susceptibility, adsorbed phosphorus and physical attributes in Oxisols of sandstones in different geomorphic surfaces. For that purpose, soil samples were collected every 25 m along a transect located within the area where the geomorphic surfaces were identified and mapped. The transect occupied the central portion of 500 ha, where it was also sampled for density purposes with one sample per six hectares. Soil samples were collected at a depth of 0.0-0.2 m. The results of the physical, chemical, mineralogical and magnetic susceptibility analyses were subjected to statistical and geostatistical analyses. The nature of the clay minerals and magnetic susceptibility was dependent on the variation of the soil parent material. High values of magnetic susceptibility were associated with the presence of maghemite and magnetite of coarse size. The spatial variability of crystallinity and the content of Fe oxides, as well as magnetic susceptibility, were dependent on the age of the geomorphic surfaces. The youngest surface had greater spatial variability of these attributes. The iron (goethite and hematite and aluminum (gibbsite oxides in the youngest geomorphic surface influenced the low values of soil density and high values of total pore volume, micropores and P adsorption. The characterization of the spatial variability of Fe oxides and susceptibility allowed for the delineation of homogeneous areas.

  2. Transmission X-ray scattering as a probe for complex liquid-surface structures

    Energy Technology Data Exchange (ETDEWEB)

    Fukuto, Masafumi; Yang, Lin; Nykypanchuk, Dmytro; Kuzmenko, Ivan

    2016-01-28

    The need for functional materials calls for increasing complexity in self-assembly systems. As a result, the ability to probe both local structure and heterogeneities, such as phase-coexistence and domain morphologies, has become increasingly important to controlling self-assembly processes, including those at liquid surfaces. The traditional X-ray scattering methods for liquid surfaces, such as specular reflectivity and grazing-incidence diffraction, are not well suited to spatially resolving lateral heterogeneities due to large illuminated footprint. A possible alternative approach is to use scanning transmission X-ray scattering to simultaneously probe local intermolecular structures and heterogeneous domain morphologies on liquid surfaces. To test the feasibility of this approach, transmission small- and wide-angle X-ray scattering (TSAXS/TWAXS) studies of Langmuir films formed on water meniscus against a vertically immersed hydrophilic Si substrate were recently carried out. First-order diffraction rings were observed in TSAXS patterns from a monolayer of hexagonally packed gold nanoparticles and in TWAXS patterns from a monolayer of fluorinated fatty acids, both as a Langmuir monolayer on water meniscus and as a Langmuir–Blodgett monolayer on the substrate. The patterns taken at multiple spots have been analyzed to extract the shape of the meniscus surface and the ordered-monolayer coverage as a function of spot position. These results, together with continual improvement in the brightness and spot size of X-ray beams available at synchrotron facilities, support the possibility of using scanning-probe TSAXS/TWAXS to characterize heterogeneous structures at liquid surfaces.

  3. OPEN CLUSTERS AS PROBES OF THE GALACTIC MAGNETIC FIELD. I. CLUSTER PROPERTIES

    Energy Technology Data Exchange (ETDEWEB)

    Hoq, Sadia; Clemens, D. P., E-mail: shoq@bu.edu, E-mail: clemens@bu.edu [Institute for Astrophysical Research, 725 Commonwealth Avenue, Boston University, Boston, MA 02215 (United States)

    2015-10-15

    Stars in open clusters are powerful probes of the intervening Galactic magnetic field via background starlight polarimetry because they provide constraints on the magnetic field distances. We use 2MASS photometric data for a sample of 31 clusters in the outer Galaxy for which near-IR polarimetric data were obtained to determine the cluster distances, ages, and reddenings via fitting theoretical isochrones to cluster color–magnitude diagrams. The fitting approach uses an objective χ{sup 2} minimization technique to derive the cluster properties and their uncertainties. We found the ages, distances, and reddenings for 24 of the clusters, and the distances and reddenings for 6 additional clusters that were either sparse or faint in the near-IR. The derived ranges of log(age), distance, and E(B−V) were 7.25–9.63, ∼670–6160 pc, and 0.02–1.46 mag, respectively. The distance uncertainties ranged from ∼8% to 20%. The derived parameters were compared to previous studies, and most cluster parameters agree within our uncertainties. To test the accuracy of the fitting technique, synthetic clusters with 50, 100, or 200 cluster members and a wide range of ages were fit. These tests recovered the input parameters within their uncertainties for more than 90% of the individual synthetic cluster parameters. These results indicate that the fitting technique likely provides reliable estimates of cluster properties. The distances derived will be used in an upcoming study of the Galactic magnetic field in the outer Galaxy.

  4. Theory of magnetic transition metal nanoclusters on surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Lounis, S.

    2007-04-17

    This thesis is motivated by the quest for the understanding and the exploration of complex magnetism provided by atomic scale magnetic clusters deposited on surfaces or embedded in the bulk. Use is made of the density functional theory (DFT). Acting within this framework, we have developed and implemented the treatment of non-collinear magnetism into the Juelich version of the full-potential Korringa-Kohn-Rostoker Green Function (KKR-GF) method. Firstly, the method was applied to 3d transition-metal clusters on different ferromagnetic surfaces. Different types of magnetic clusters where selected. In order to investigate magnetic frustration due to competing interactions within the ad-cluster we considered a (001) oriented surface of fcc metals, a topology which usually does not lead to non-collinear magnetism. We tuned the strength of the magnetic coupling between the ad-clusters and the ferromagnetic surface by varying the substrate from the case of Ni(001) with a rather weak hybridization of the Ni d-states with the adatom d-states to the case of Fe{sub 3ML}/Cu(001) with a much stronger hybridization due to the larger extend of the Fe wavefunctions. On Ni(001), the interaction between the Cr- as well as the Mn-dimer adatoms is of antiferromagnetic nature, which is in competition with the interaction with the substrate atoms. After performing total energy calculations we find that for Cr-dimer the ground state is collinear whereas the Mn-dimer prefers the non-collinear configuration as ground state. Bigger clusters are found to be magnetically collinear. These calculations were extended to 3d multimers on Fe{sub 3ML}/Cu(001). All neighboring Cr(Mn) moments in the compact tetramer are antiferromagnetically aligned in-plane, with the directions slightly tilted towards (outwards from) the substrate to gain some exchange interaction energy. The second type of frustration was investigated employing a Ni(111) surface, a surface with a triangular lattice of atoms, were

  5. Surface electronic transport measurements: A micro multi-point probe approach

    DEFF Research Database (Denmark)

    Barreto, Lucas

    2014-01-01

    This work is mostly focused on the study of electronic transport properties of two-dimensional materials, in particular graphene and topological insulators. To study these, we have improved a unique micro multi-point probe instrument used to perform transport measurements. Not only the experimental...... quantities are extracted, such as conductivity, carrier density and carrier mobility. • A method to insulate electrically epitaxial graphene grown on metals, based on a stepwise intercalation methodology, is developed and transport measurements are performed in order to test the insulation. • We show...... a direct measurement of the surface electronic transport on a bulk topological insulator. The surface state conductivity and mobility are obtained. Apart from transport properties, we also investigate the atomic structure of the Bi2Se3(111) surface via surface x-ray diraction and low-energy electron...

  6. High-Resolution Magnetic Force Microscopy Using Carbon Nanotube Probes Fabricated Directly by Microwave Plasma-Enhanced Chemical Vapor Deposition

    Directory of Open Access Journals (Sweden)

    Kei Tanaka

    2009-01-01

    Full Text Available Carbon nanotubes (CNTs have been successfully grown on the tip apex of an atomic force microscopy (AFM cantilever by microwave plasma-enhanced chemical vapor deposition (MPECVD. Both scanning electron microscopy (SEM and transmission electron microscopy (TEM observations reveal that the diameter of the CNTs is ∼30 nm and the magnetic particles with diameter of ∼20 nm, which was used as catalyst for the CNT growth, exist on the top. This CNT probe has been applied to magnetic force microscopy (MFM on the ultrahigh-density magnetic recording media with 1200 kilo flux change per inch (kfci.

  7. Magnetic nanoparticles: surface effects and properties related to biomedicine applications.

    Science.gov (United States)

    Issa, Bashar; Obaidat, Ihab M; Albiss, Borhan A; Haik, Yousef

    2013-10-25

    Due to finite size effects, such as the high surface-to-volume ratio and different crystal structures, magnetic nanoparticles are found to exhibit interesting and considerably different magnetic properties than those found in their corresponding bulk materials. These nanoparticles can be synthesized in several ways (e.g., chemical and physical) with controllable sizes enabling their comparison to biological organisms from cells (10-100 μm), viruses, genes, down to proteins (3-50 nm). The optimization of the nanoparticles' size, size distribution, agglomeration, coating, and shapes along with their unique magnetic properties prompted the application of nanoparticles of this type in diverse fields. Biomedicine is one of these fields where intensive research is currently being conducted. In this review, we will discuss the magnetic properties of nanoparticles which are directly related to their applications in biomedicine. We will focus mainly on surface effects and ferrite nanoparticles, and on one diagnostic application of magnetic nanoparticles as magnetic resonance imaging contrast agents.

  8. The Probing Radio Signal Polarization Effect on Separation Efficiency of Surface Target Response

    Directory of Open Access Journals (Sweden)

    A. N. Pinchuk

    2015-01-01

    Full Text Available The aim of the study was a quantitative analysis of the level of interference with radar monitoring characteristics of surface targets, caused by the scattered electromagnetic field, arising due to the interaction between radio waves and sea surface, which is a study aspect a radiooceanography encompasses. Backscatter signal, arising from the interaction of radio waves and sea surface, extends in a direction opposite the probing radar signal of spread marine and coastal radar stations.With radar sounding of sea surface at high incidence angles of radio waves, a basic physical mechanism to form the received signal is resonant (Bragg scattering, and at small incidence angles of radio waves it is quasi-specular reflection. Consequently, the energy of electromagnetic radiation, backscattered by the sea surface, depends on the type of wave polarization: for horizontal polarization it is less than for vertical one.The paper presents a mathematical model, which describes dependence of interference level caused by interaction between radio waves and sea surface, on the radio wave polarization for the case when the same polarization is used to sent-out and receive a radio wave.To determine the noise reduction to be achievable with radar monitoring the surface targets by selecting the polarization of the probing radar signal, a signal/noise ratio is analyzed for its different polarizations.It is shown that in order to reduce the noise level caused by the interaction between radio waves and sea surface, it is possible to use the differences in the level of scattered radio signals of different polarization: with horizontally-polarized radar operation at incidence angles of 75°- 85° a signal/noise ratio is by 20-35 dB higher than that of vertically- polarized one.

  9. Signal Evaluation System of Flexible Array Ect Probes for Inspecting Complexly Shaped Surfaces

    Science.gov (United States)

    Endo, H.; Nishimizu, A.; Tooma, M.; Ouchi, H.; Yoshida, I.; Nonaka, Y.; Otani, K.

    2011-06-01

    We developed a signal evaluation system of flexible array eddy current testing (ECT) probes for inspecting complexly shaped metal surfaces. Our probes employ excitation and pickup coil pairs arrayed on a bendable substrate to measure curved targets. Since the developed probes produce signals due to the change in the relative position between the coil pair, an evaluation module for flaw signal identification is integrated into the system. The identification utilizes signal phase combination of the coil pairs. It is represented as a two-dimensional diagram constituting the phase values of two of the coil pairs with different positions. The phase of signals around flaws is significantly affected by their orientations. The diagram is therefore capable of separating flaw information from other information and of imaging flaw positions. We applied the system to complex geometric mock-ups. Flaw signals were successfully identified and the images obtained for identified positions could be used to efficiently measure the length of surface flaws by the 12 decibel down method.

  10. Study of plasma-material surface interaction using Langmuir probe technique during plasma treatment

    International Nuclear Information System (INIS)

    Saloum, S.; Akel, M.

    2009-06-01

    In this study, we tried to understand the plasma-surface interactions by using Langmuir probes. Two different types of plasmas were studied, the first is the electropositive plasma in Argon and the second is the electronegative plasma in Sulfur Hexafluoride. In the first type, the effects of Argon gas pressure, the injection of Helium in the remote zone and the substrate bias on the measurements of the Electron Energy Probability Function (EEPF) and on the plasma parameters (electron density (n e ), effective electron temperature (T e ff), plasma potential (V p ) and floating potential (V f )) have been investigated. The obtained EEPFs and plasma parameters have been used to control two remote plasma processes. The first is the remote Plasma Enhanced Chemical Vapor Deposition (PE-CVD) of thin films, on silicon wafers, from Hexamethyldisoloxane (HMDSO) precursor diluted in the remote Ar-He plasma. The second is the pure Argon remote plasma treatment of polymethylmethacrylate (PMMA) polymer surface. In the second type, the plasma diagnostics were performed in the remote zone as a function of SF 6 flow rate, where relative concentrations of fluorine atoms were measured using actinometry optical emission spectroscopy; electron density, electron temperature and plasma potential were determined using single cylindrical Langmuir probe, positive ion flux and negative ion fraction were determined using an planar probe. The silicon etching process in SF 6 plasma was studied. (author)

  11. Oxidation of clean silicon surfaces studied by four-point probe surface conductance measurements

    DEFF Research Database (Denmark)

    Petersen, Christian Leth; Grey, Francois; Aono, M.

    1997-01-01

    We have investigated how the conductance of Si(100)-(2 x 1) and Si(111)-(7 x 7) surfaces change during exposure to molecular oxygen. A monotonic decrease in conductance is seen as the (100) surfaces oxidizes. In contract to a prior study, we propose that this change is caused by a decrease in sur...

  12. A large volume double channel 1H-X RF probe for hyperpolarized magnetic resonance at 0.0475 T

    Science.gov (United States)

    Coffey, Aaron M.; Shchepin, Roman V.; Wilkens, Ken; Waddell, Kevin W.; Chekmenev, Eduard Y.

    2012-07-01

    In this work we describe a large volume 340 mL 1H-X magnetic resonance (MR) probe for studies of hyperpolarized compounds at 0.0475 T. 1H/13C and 1H/15N probe configurations are demonstrated with the potential for extension to 1H/129Xe. The primary applications of this probe are preparation and quality assurance of 13C and 15N hyperpolarized contrast agents using PASADENA (parahydrogen and synthesis allow dramatically enhanced nuclear alignment) and other parahydrogen-based methods of hyperpolarization. The probe is efficient and permits 62 μs 13C excitation pulses at 5.3 W, making it suitable for portable operation. The sensitivity and detection limits of this probe, tuned to 13C, are compared with a commercial radio frequency (RF) coil operating at 4.7 T. We demonstrate that low field MR of hyperpolarized contrast agents could be as sensitive as conventional high field detection and outline potential improvements and optimization of the probe design for preclinical in vivo MRI. PASADENA application of this low-power probe is exemplified with 13C hyperpolarized 2-hydroxyethyl propionate-1-13C,2,3,3-d3.

  13. Note: Development of a multichannel magnetic probe array for magnetohydrodynamic activity studies in Sino-United Spherical Tokamak

    Science.gov (United States)

    Zhong, H.; Tan, Y.; Gao, Z.

    2018-02-01

    A 30-channel movable magnetic probe radial array measuring the poloidal magnetic field's time derivative B˙ θ has been developed and installed on the Sino-United Spherical Tokamak to investigate the magnetohydrodynamic (MHD) activities in ohmic discharges. The probe array consists of thirty identical commercial chip inductors mounted on a slim printed circuit board and shielded by a customized quartz tube of 14 mm in outer diameter. With the application of instrumentation amplifiers, the system exhibits a good signal to noise ratio and the measured vertical field spatial distribution agrees well with the simulation result. The measured spatial and temporal distribution of B˙ θ during the MHD activities exhibits a clear phase reversal layer, which is a direct proof of tearing mode and provides a reliable indication of the magnetic island chain position.

  14. Surface functionalized magnetic nanoparticles shift cell behavior with on/off magnetic fields.

    Science.gov (United States)

    Jeon, Seongbeom; Subbiah, Ramesh; Bonaedy, Taufik; Van, Seyoung; Park, Kwideok; Yun, Kyusik

    2018-02-01

    Magnetic nanoparticles (MNPs) are used as contrast agents and targeted drug delivery systems (TDDS) due to their favorable size, surface charge, and magnetic properties. Unfortunately, the toxicity associated with MNPs limits their biological applications. Surface functionalization of MNPs with selective polymers alters the surface chemistry to impart better biocompatibility. We report the preparation of surface functionalized MNPs using iron oxide NPs (MNPs), poly (lactic-co-glycolic acid) (PLGA), and sodium alginate via co-precipitation, emulsification, and electro-spraying, respectively. The NPs are in the nanosize range and negatively charged. Morphological and structural analyses affirm the surface functionalized nanostructure of the NPs. The surface functionalized MNPs are biocompatible, and demonstrate enhanced intracellular delivery under an applied magnetic field (H), which evinces the targeting ability of MNPs. After NP treatment, the physico-mechanical properties of fibroblasts are decided by the selective MNP uptake under "on" or "off" magnetic field conditions. We envision potential use of biocompatible surface functionalized MNP for intracellular-, targeted-DDS, imaging, and for investigating cellular mechanics. © 2017 Wiley Periodicals, Inc.

  15. Destruction of Invariant Surfaces and Magnetic Coordinates for Perturbed Magnetic Fields

    International Nuclear Information System (INIS)

    Hudson, S.R.

    2003-01-01

    Straight-field-line coordinates are constructed for nearly integrable magnetic fields. The coordinates are based on the robust, noble-irrational rotational-transform surfaces, whose existence is determined by an application of Greene's residue criterion. A simple method to locate these surfaces is described. Sequences of surfaces with rotational-transform converging to low order rationals maximize the region of straight-field-line coordinates

  16. Mesogranulation and the Solar Surface Magnetic Field Distribution

    Science.gov (United States)

    Yelles Chaouche, L.; Moreno-Insertis, F.; Martínez Pillet, V.; Wiegelmann, T.; Bonet, J. A.; Knölker, M.; Bellot Rubio, L. R.; del Toro Iniesta, J. C.; Barthol, P.; Gandorfer, A.; Schmidt, W.; Solanki, S. K.

    2011-02-01

    The relation of the solar surface magnetic field with mesogranular cells is studied using high spatial (≈100 km) and temporal (≈30 s) resolution data obtained with the IMaX instrument on board SUNRISE. First, mesogranular cells are identified using Lagrange tracers (corks) based on horizontal velocity fields obtained through local correlation tracking. After ≈20 minutes of integration, the tracers delineate a sharp mesogranular network with lanes of width below about 280 km. The preferential location of magnetic elements in mesogranular cells is tested quantitatively. Roughly 85% of pixels with magnetic field higher than 100 G are located in the near neighborhood of mesogranular lanes. Magnetic flux is therefore concentrated in mesogranular lanes rather than intergranular ones. Second, magnetic field extrapolations are performed to obtain field lines anchored in the observed flux elements. This analysis, therefore, is independent of the horizontal flows determined in the first part. A probability density function (PDF) is calculated for the distribution of distances between the footpoints of individual magnetic field lines. The PDF has an exponential shape at scales between 1 and 10 Mm, with a constant characteristic decay distance, indicating the absence of preferred convection scales in the mesogranular range. Our results support the view that mesogranulation is not an intrinsic convective scale (in the sense that it is not a primary energy-injection scale of solar convection), but also give quantitative confirmation that, nevertheless, the magnetic elements are preferentially found along mesogranular lanes.

  17. Nanoscale Surface Photovoltage Mapping of 2D Materials and Heterostructures by Illuminated Kelvin Probe Force Microscopy

    KAUST Repository

    Shearer, Melinda J.

    2018-02-01

    Nanomaterials are interesting for a variety of applications, such as optoelectronics and photovoltaics. However, they often have spatial heterogeneity, i.e. composition change or physical change in the topography or structure, which can lead to varying properties that would influence their applications. New techniques must be developed to understand and correlate spatial heterogeneity with changes in electronic properties. Here we highlight the technique of surface photovoltage-Kelvin probe force microscopy (SPV-KFM), which is a modified version of non-contact atomic force microscopy capable of imaging not only the topography and surface potential, but also the surface photovoltage on the nanoscale. We demonstrate its utility in probing monolayer WSe2-MoS2 lateral heterostructures, which form an ultrathin p-n junction promising for photovoltaic and optoelectronic applications. We show surface photovoltage maps highlighting the different photoresponse of the two material regions as a result of the effective charge separation across this junction. Additionally, we study the variations between different heterostructure flakes and emphasize the importance of controlling the synthesis and transfer of these materials to obtain consistent properties and measurements.

  18. In situ X-ray probing reveals fingerprints of surface platinum oxide.

    Science.gov (United States)

    Friebel, Daniel; Miller, Daniel J; O'Grady, Christopher P; Anniyev, Toyli; Bargar, John; Bergmann, Uwe; Ogasawara, Hirohito; Wikfeldt, Kjartan Thor; Pettersson, Lars G M; Nilsson, Anders

    2011-01-07

    In situ X-ray absorption spectroscopy (XAS) at the Pt L(3) edge is a useful probe for Pt-O interactions at polymer electrolyte membrane fuel cell (PEMFC) cathodes. We show that XAS using the high energy resolution fluorescence detection (HERFD) mode, applied to a well-defined monolayer Pt/Rh(111) sample where the bulk penetrating hard X-rays probe only surface Pt atoms, provides a unique sensitivity to structure and chemical bonding at the Pt-electrolyte interface. Ab initio multiple-scattering calculations using the FEFF code and complementary extended X-ray absorption fine structure (EXAFS) results indicate that the commonly observed large increase of the white-line at high electrochemical potentials on PEMFC cathodes originates from platinum oxide formation, whereas previously proposed chemisorbed oxygen-containing species merely give rise to subtle spectral changes.

  19. In Situ X-Ray Probing Reveals Fingerprints of Surface Platinum Oxide

    Energy Technology Data Exchange (ETDEWEB)

    Friebel, Daniel

    2011-08-24

    In situ x-ray absorption spectroscopy (XAS) at the Pt L{sub 3} edge is a useful probe for Pt-O interactions at polymer electrolyte membrane fuel cell (PEMFC) cathodes. We show that XAS using the high energy resolution fluorescence detection (HERFD) mode, applied to a well-defined monolayer Pt/Rh(111) sample where the bulk penetrating hard x-rays probe only surface Pt atoms, provides a unique sensitivity to structure and chemical bonding at the Pt-electrolyte interface. Ab initio multiple-scattering calculations using the FEFF8 code and complementary extended x-ray absorption fine structure (EXAFS) results indicate that the commonly observed large increase of the white-line at high electrochemical potentials on PEMFC cathodes originates from platinum oxide formation, whereas previously proposed chemisorbed oxygen-containing species merely give rise to subtle spectral changes.

  20. Surface structure of quark stars with magnetic fields

    Indian Academy of Sciences (India)

    the formation of quark stars, with particular attention to the attractive quark-nova scenario which may be connected to r-process nucleosynthesis. 2. Degenerate electron gas in a strong magnetic field. Recently, a few authors [21] pointed out that the deficit of (massive) strange quarks due to surface effects on the star can lead ...

  1. Surface-modified magnetic nanoparticles for cell labeling

    Czech Academy of Sciences Publication Activity Database

    Zasońska, Beata Anna; Patsula, Vitalii; Stoika, R.; Horák, Daniel

    2014-01-01

    Roč. 13, č. 4 (2014), s. 63-73 ISSN 2305-7815 R&D Projects: GA MŠk(CZ) LH14318 Institutional support: RVO:61389013 Keywords : magnetic nanoparticles * surface-modified * cell labeling Subject RIV: CD - Macromolecular Chemistry

  2. Noncollinear magnetism in surfaces and interfaces of transition metals

    Energy Technology Data Exchange (ETDEWEB)

    Tan, Huahai

    2009-09-15

    Noncollinear (NC) magnetism is common in nature, especially when there exist geometrical frustration and chemical imparity in the system. In this work we studied the NC magnetism and the response to external magnetic fields in surfaces and interfaces of transition metals by using an semi-empirical tight-binding (TB) method that parameterized to the ab initio TB-LMTO calculations. We implemented this method to study two systems. The first one is the system of 6 Mn monolayers on Fe(001) substrate. Due to the complex structure and magnetic properties of Mn, we found 23 collinear magnetic configurations but only one NC configuration. The collinear ground state has a layered antiferromagnetic (AFM) coupling which agrees with previous experiments and calculations. In the NC configuration the local AFM coupling in the Mn layers is preserved, but the surface is 90 degree coupled to the substrate. Similar to the experiment in CdCr{sub 2}O{sub 4}, we obtained a collinear plateau in the NC evolution of the average magnetic moment in Mn slab under external magnetic fields. Another is the system of a Cr monolayer on a stepped Fe(001) substrate. As expected, the local AFM coupling in the interface of Cr and Fe are preserved. However, the edge Cr atoms is about 90 coupled to their nearest Fe neighbors. We also simulated the procedure of adding more Cr coverages gradually to a Cr bilayer coverage. As coverages increase, the magnetic moments in the Cr interface reduce, and the collinear plateau becomes wider as coverages increase. However, the saturation fields in both the two systems are extremely high, around 10 kT.We expect that when the effect of temperature is taken into account, and in some proper systems, the saturation fields could be largely reduced to the scale that can be implemented in experiment, and our study may shed light on information storage devices with ultrahigh storage density. (orig.)

  3. A dual-modal magnetic nanoparticle probe for preoperative and intraoperative mapping of sentinel lymph nodes by magnetic resonance and near infrared fluorescence imaging.

    Science.gov (United States)

    Zhou, Zhengyang; Chen, Hongwei; Lipowska, Malgorzata; Wang, Liya; Yu, Qiqi; Yang, Xiaofeng; Tiwari, Diana; Yang, Lily; Mao, Hui

    2013-07-01

    The ability to reliably detect sentinel lymph nodes for sentinel lymph node biopsy and lymphadenectomy is important in clinical management of patients with metastatic cancers. However, the traditional sentinel lymph node mapping with visible dyes is limited by the penetration depth of light and fast clearance of the dyes. On the other hand, sentinel lymph node mapping with radionucleotide technique has intrinsically low spatial resolution and does not provide anatomic details in the sentinel lymph node mapping procedure. This work reports the development of a dual modality imaging probe with magnetic resonance and near infrared imaging capabilities for sentinel lymph node mapping using magnetic iron oxide nanoparticles (10 nm core size) conjugated with a near infrared molecule with emission at 830 nm. Accumulation of magnetic iron oxide nanoparticles in sentinel lymph nodes leads to strong T2 weighted magnetic resonance imaging contrast that can be potentially used for preoperative localization of sentinel lymph nodes, while conjugated near infrared molecules provide optical imaging tracking of lymph nodes with a high signal to background ratio. The new magnetic nanoparticle based dual imaging probe exhibits a significant longer lymph node retention time. Near infrared signals from nanoparticle conjugated near infrared dyes last up to 60 min in sentinel lymph node compared to that of 25 min for the free near infrared dyes in a mouse model. Furthermore, axillary lymph nodes, in addition to sentinel lymph nodes, can be also visualized with this probe, given its slow clearance and sufficient sensitivity. Therefore, this new dual modality imaging probe with the tissue penetration and sensitive detection of sentinel lymph nodes can be applied for preoperative survey of lymph nodes with magnetic resonance imaging and allows intraoperative sentinel lymph node mapping using near infrared optical devices.

  4. Use of low energy alkali ion scattering as a probe of surface structure

    International Nuclear Information System (INIS)

    Overbury, S.H.

    1986-01-01

    An overview is given of the use of low energy ion scattering as a probe of surface structure with emphasis on work done using alkali ions. Various schemes for extracting structural information from the ion energy and angle distributions are discussed in terms of advantages and disadvantages of each. The scattering potential which is the primary non-structural parameter needed for analysis, is discussed in terms of recent experimental results. The structure of clean and reconstructed surfaces are discussed, with examples of measurements of layer relaxations on the Mo(111) surface and missing row reconstructions on the Au(110) and Pt(110) surfaces. Studies of adsorbate covered surfaces are presented with respect to location of the adsorbate and its effect on the structure of the underlying substrate. Finally, examples are given which demonstrate the sensitivity of ion scattering to surface defects and disordering on reconstructed Au(110) and Pt(110) surfaces and unreconstructed Mo(111) surfaces, and to ordering of adsorbates on Mo(001). 47 refs., 12 figs

  5. Electric control of magnetism in low-dimensional magnets on ferroelectric surfaces

    Directory of Open Access Journals (Sweden)

    Dorj Odkhuu

    2017-05-01

    Full Text Available Employing first-principles electronic structure calculations, we have studied the electric field controls of magnetism and magnetic anisotropy energy (MAE of the Fe adatoms on ferroelectric BaTiO3 and PbTiO3 surfaces. Remarkably, those effects exhibit dependence of the level of coverage as well as adsorption site of Fe atoms. While the magnitude of MAE is shown tunable by ferroelectric polarization in the full coverage of Fe monolayer, the direction of magnetization undergoes a transition from perpendicular to in-plane for the half or lower coverages. This magnetization reorientation is mainly ascribed to the site-dependent Fe d–O p hybridization, as a consequence of the formation of FeTiO2 layer at the surface.

  6. THE INTEGRATED USE OF COMPUTATIONAL CHEMISTRY, SCANNING PROBE MICROSCOPY, AND VIRTUAL REALITY TO PREDICT THE CHEMICAL REACTIVITY OF ENVIRONMENTAL SURFACES

    Science.gov (United States)

    In the last decade three new techniques scanning probe microscopy (SPM), virtual reality (YR) and computational chemistry ave emerged with the combined capability of a priori predicting the chemically reactivity of environmental surfaces. Computational chemistry provides the cap...

  7. Probing the Surface of Platinum during the Hydrogen Evolution Reaction in Alkaline Electrolyte

    Energy Technology Data Exchange (ETDEWEB)

    Stoerzinger, Kelsey A. [Physical; Favaro, Marco [Advanced; Joint; Chemical; Ross, Philip N. [Materials; Yano, Junko [Joint; Molecular; Liu, Zhi [State; Division; Hussain, Zahid [Advanced; Crumlin, Ethan J. [Advanced; Joint Center

    2017-11-02

    Understanding the surface chemistry of electrocatalysts in operando can bring insight into the reaction mechanism, and ultimately the design of more efficient materials for sustainable energy storage and conversion. Recent progress in synchrotron based X-ray spectroscopies for in operando characterization allows us to probe the solid/liquid interface directly while applying an external potential, applied here to the model system of Pt in alkaline electrolyte for the hydrogen evolution reaction (HER). We employ ambient pressure X-ray photoelectron spectroscopy (AP-XPS) to identify the oxidation and reduction of Pt-oxides and hydroxides on the surface as a function of applied potential, and further assess the potential for hydrogen adsorption and absorption (hydride formation) during and after the HER. This new window into the surface chemistry of Pt in alkaline brings insight into the nature of the rate limiting step, the extent of H ad/absorption and it’s persistence at more anodic potentials.

  8. Evaluation of surface decarburization depth by magnetic Barkhausen noise technique

    Energy Technology Data Exchange (ETDEWEB)

    Stupakov, O., E-mail: stupak@fzu.c [Institute of Physics of the AS CR, v.v.i., Na Slovance 2, 18221 Prague (Czech Republic); Perevertov, O.; Tomas, I. [Institute of Physics of the AS CR, v.v.i., Na Slovance 2, 18221 Prague (Czech Republic); Skrbek, B. [Technical University of Liberec, Studentska 2, 46117 Liberec (Czech Republic)

    2011-06-15

    Industrially unfavorable process of steel surface decarburization was induced by annealing in air. Two methods of after-anneal surface treatment were used: an acid pickling and a sand blasting. The obtained decarburized layers were examined by optical microscope, wave dispersive spectrometer, and surface X-ray diffraction method. Magnetic Barkhausen noise technique was tested for applicability of non-destructive characterization of the decarburized layer depth. A newly introduced parameter, Barkhausen noise coercivity, was proposed for practical use due to its sensitivity to decarburization and stability to measurement conditions. Other magnetic parameters, e.g. number of Barkhausen noise counts, were found to be sensitive to the compressive residual stress caused by the sand blasting. - Research highlights: Barkhausen coercivity shows good stability and sensitivity to decarburization depth. Number of Barkhausen noise counts indicates compressive residual stress. Rms value of Barkhausen noise shows nonmonotonic dependence on decarburization depth.

  9. Probing the surface profile and friction behavior of heterogeneous polymers: a molecular dynamics study

    Science.gov (United States)

    Dai, L.; Sorkin, V.; Zhang, Y. W.

    2017-04-01

    We perform molecular dynamics simulations to investigate molecular structure alternation and friction behavior of heterogeneous polymer (perfluoropolyether) surfaces using a nanoscale probing tip (tetrahedral amorphous carbon). It is found that depending on the magnitude of the applied normal force, three regimes exist: the shallow depth-sensing (SDS), deep depth-sensing (DDS), and transitional depth-sensing (TDS) regimes; TDS is between SDS and DDS. In SDS, the tip is floating on the polymer surface and there is insignificant permanent alternation in the polymer structure due to largely recoverable atomic deformations, and the surface roughness profile can be accurately measured. In DDS, the tip is plowing through the polymer surface and there is significant permanent alternation in the molecular structure. In this regime, the lateral friction force rises sharply and fluctuates violently when overcoming surface pile-ups. In SDS, the friction can be described by a modified Amonton’s law including the adhesion effect; meanwhile, in DDS, the adhesion effect is negligible but the friction coefficient is significantly higher. The underlying reason for the difference in these regimes rests upon different contributions by the repulsion and attraction forces between the tip and polymer surfaces to the friction force. Our findings here reveal important insights into lateral depth-sensing on heterogeneous polymer surfaces and may help improve the precision of depth-sensing devices.

  10. Atomic species recognition on oxide surfaces using low temperature scanning probe microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Zong Min, E-mail: mzmncit@163.com [National Key Laboratory for Electronic Measurement Technology, North University of China, Taiyuan, 030051 (China); Key Laboratory of Instrumentation Science & Dynamic Measurement, North University of China, Ministry of Education, Taiyuan, 030051 (China); School of Instrument and Electronics, North University of China, Taiyuan, 030051 (China); Shi, Yun Bo; Mu, Ji Liang; Qu, Zhang; Zhang, Xiao Ming; Qin, Li [National Key Laboratory for Electronic Measurement Technology, North University of China, Taiyuan, 030051 (China); Key Laboratory of Instrumentation Science & Dynamic Measurement, North University of China, Ministry of Education, Taiyuan, 030051 (China); School of Instrument and Electronics, North University of China, Taiyuan, 030051 (China); Liu, Jun, E-mail: liuj@nuc.edu.cn [National Key Laboratory for Electronic Measurement Technology, North University of China, Taiyuan, 030051 (China); Key Laboratory of Instrumentation Science & Dynamic Measurement, North University of China, Ministry of Education, Taiyuan, 030051 (China); School of Instrument and Electronics, North University of China, Taiyuan, 030051 (China)

    2017-02-01

    Highlights: • The coexisted phase of p(2 × 1)and c(6 × 2) on Cu(110)-O surface using AFM under UHV at low temperature. • Two different c(6 × 2) phase depending on the status of the tip apex. • Electronic state of tip seriously effect the resolution and stability of the sample surface. - Abstract: In scanning probe microscopy (SPM), the chemical properties and sharpness of the tips of the cantilever greatly influence the scanning of a sample surface. Variation in the chemical properties of the sharp tip apex can induce transformation of the SPM images. In this research, we explore the relationship between the tip and the structure of a sample surface using dynamic atomic force microscopy (AFM) on a Cu(110)-O surface under ultra-high vacuum (UHV) at low temperature (78 K). We observed two different c(6 × 2) phase types in which super-Cu atoms show as a bright spot when the tip apex is of O atoms and O atoms show as a bright spot when the tip apex is of Cu atoms. We also found that the electronic state of the tip has a serious effect on the resolution and stability of the sample surface, and provide an explanation for these phenomena. This technique can be used to identify atom species on sample surfaces, and represents an important development in the SPM technique.

  11. Determination of self generated magnetic field and the plasma density using Cotton Mouton polarimetry with two color probes

    Directory of Open Access Journals (Sweden)

    Joshi A.S.

    2013-11-01

    Full Text Available Self generated magnetic fields (SGMF in laser produced plasmas are conventionally determined by measuring the Faraday rotation angle of a linearly polarized laser probe beam passing through the plasma along with the interferogram for obtaining plasma density. In this paper, we propose a new method to obtain the plasma density and the SGMF distribution from two simultaneous measurements of Cotton Mouton polarimetry of two linearly polarized probe beams of different colors that pass through plasma in a direction normal to the planar target. It is shown that this technique allows us to determine the distribution of SGMF and the plasma density without doing interferometry of laser produced plasmas.

  12. Overview of magnetic bias X-probe qualification and inspection of PNGS Monel 400 steam generator tubing

    International Nuclear Information System (INIS)

    Lepine, B.A.; Van Langen, J.; Obrutsky, L.

    2006-01-01

    This paper presents an overview of the X-probe MB 350, the qualification for detection of open OD axial crack-like flaws, and a selection of inspection results from the subsequent field inspections performed with this probe during the 2003 and 2004 period at Pickering Nuclear Generating Station A and B. Examples of the field indications to be presented are axial cracking, OD pitting at top of tubesheet location (TTS), and flow assisted corrosion (top hats). During the 2003 in-service eddy current inspection results of Pickering Nuclear Generating Station A (PNGS-A) Unit 2, a 13 mm (0.5 inch) long axial indication was detected by the CTR1 bobbin and CTR2-C4 array probes in Tube R25-C52 of Steam Generator (SG) 11 in the hot leg sludge pile region. An experimental magnetic bias X-probe, especially designed by Zetec for inspection of Monel 400 tubing, was deployed and the indication was characterized as a potential outer diameter (OD) axially oriented crack. Posterior tube pulling and destructive examination confirmed the presence of an Environmentally Assisted Crack (EAC), approximately 80% deep and 13 mm long. Due to the significance of this discovery, Ontario Power Generation (OPG) requested AECL to initiate a program for qualification of the X-Probe MB 350 for the detection of OD axial cracks in medium to high magnetic permeability (μ r ) Monel 400 PNGS-A and B steam generator tubing at different locations. The X-probe MB 350 subsequently has been deployed as a primary inspection probe for crack detection for PNGS steam generators. (author)

  13. AFM Colloidal Probe Measurements Implicate Capillary Condensation in Punch-Particle Surface Interactions during Tableting.

    Science.gov (United States)

    Badal Tejedor, Maria; Nordgren, Niklas; Schuleit, Michael; Millqvist-Fureby, Anna; Rutland, Mark W

    2017-11-21

    Adhesion of the powders to the punches is a common issue during tableting. This phenomenon is known as sticking and affects the quality of the manufactured tablets. Defective tablets increase the cost of the manufacturing process. Thus, the ability to predict the tableting performance of the formulation blend before the process is scaled-up is important. The adhesive propensity of the powder to the tableting tools is mostly governed by the surface-surface adhesive interactions. Atomic force microscopy (AFM) colloidal probe is a surface characterization technique that allows the measurement of the adhesive interactions between two materials of interest. In this study, AFM steel colloidal probe measurements were performed on ibuprofen, MCC (microcrystalline cellulose), α-lactose monohydrate, and spray-dried lactose particles as an approach to modeling the punch-particle surface interactions during tableting. The excipients (lactose and MCC) showed constant, small, attractive, and adhesive forces toward the steel surface after a repeated number of contacts. In comparison, ibuprofen displayed a much larger attractive and adhesive interaction increasing over time both in magnitude and in jump-in/jump-out separation distance. The type of interaction acting on the excipient-steel interface can be related to a van der Waals force, which is relatively weak and short-ranged. By contrast, the ibuprofen-steel interaction is described by a capillary force profile. Even though ibuprofen is not highly hydrophilic, the relatively smooth surfaces of the crystals allow "contact flooding" upon contact with the steel probe. Capillary forces increase because of the "harvesting" of moisture-due to the fast condensation kinetics-leaving a residual condensate that contributes to increase the interaction force after each consecutive contact. Local asperity contacts on the more hydrophilic surface of the excipients prevent the flooding of the contact zone, and there is no such adhesive

  14. Observational Effects of Magnetism in O Stars: Surface Nitrogen Abundances

    Science.gov (United States)

    Martins, F.; Escolano, C.; Wade, G. A.; Donati, J. F.; Bouret, J. C.

    2011-01-01

    Aims. We investigate the surface nitrogen content of the six magnetic O stars known to date as well as of the early B-type star Tau Sco.. We compare these abundances to predictions of evolutionary models to isolate the effects of magnetic field on the transport of elements in stellar interiors. Methods. We conduct a quantitative spectroscopic analysis of the ample stars with state-of-the-art atmosphere models. We rely on high signal-to-noise ratio, high resolution optical spectra obtained with ESPADONS at CFHT and NARVAL at TBL. Atmosphere models and synthetic spectra are computed with the code CMFGEN. Values of N/H together with their uncertainties are determined and compared to predictions of evolutionary models. Results. We find that the magnetic stars can be divided into two groups: one with stars displaying no N enrichment (one object); and one with stars most likely showing extra N enrichment (5 objects). For one star (Ori C) no robust conclusion can be drawn due to its young age. The star with no N enrichment is the one with the weakest magnetic field, possibly of dynamo origin. It might be a star having experienced strong magnetic braking under the condition of solid body rotation, but its rotational velocity is still relatively large. The five stars with high N content were probably slow rotators on the zero age main sequence, but they have surface N/H typical of normal O stars, indicating that the presence of a (probably fossil) magnetic field leads to extra enrichment. These stars may have a strong differential rotation inducing shear mixing. Our results shOuld be viewed as a basis on which new theoretical simulations can rely to better understand the effect of magnetism on the evolution of massive stars.

  15. A rapid method for detection of genetically modified organisms based on magnetic separation and surface-enhanced Raman scattering.

    Science.gov (United States)

    Guven, Burcu; Boyacı, İsmail Hakkı; Tamer, Ugur; Çalık, Pınar

    2012-01-07

    In this study, a new method combining magnetic separation (MS) and surface-enhanced Raman scattering (SERS) was developed to detect genetically modified organisms (GMOs). An oligonucleotide probe which is specific for 35 S DNA target was immobilized onto gold coated magnetic nanospheres to form oligonucleotide-coated nanoparticles. A self assembled monolayer was formed on gold nanorods using 5,5'-dithiobis (2-nitrobenzoic acid) (DTNB) and the second probe of the 35 S DNA target was immobilized on the activated nanorod surfaces. Probes on the nanoparticles were hybridized with the target oligonucleotide. Optimization parameters for hybridization were investigated by high performance liquid chromatography. Optimum hybridization parameters were determined as: 4 μM probe concentration, 20 min immobilization time, 30 min hybridization time, 55 °C hybridization temperature, 750 mM buffer salt concentration and pH: 7.4. Quantification of the target concentration was performed via SERS spectra of DTNB on the nanorods. The correlation between the target concentration and the SERS signal was found to be linear within the range of 25-100 nM. The analyses were performed with only one hybridization step in 40 min. Real sample analysis was conducted using Bt-176 maize sample. The results showed that the developed MS-SERS assay is capable of detecting GMOs in a rapid and selective manner. This journal is © The Royal Society of Chemistry 2012

  16. A new optical method for measuring surface temperature at large incident probe angles

    Science.gov (United States)

    Lee, A. S.; Norris, P. M.

    1997-02-01

    A novel thermoreflectance technique has been developed for noncontact temperature measurements using laser light incident at large angles on solid materials and devices. The method involves measuring the differential reflectance from a polarization modulated laser beam. The polarization differential reflectance technique is demonstrated on single-crystal Si wafers and on a polycrystalline carbon thin film over a temperature range of 20-60 °C. The method is shown to be an extremely sensitive temperature probe for near grazing angle measurements, which could be useful for monitoring the surface temperature of closely stacked silicon wafers used in batch processing in the microelectronics industry.

  17. Probing feedforward and feedback contributions to awareness with visual masking and transcranial magnetic stimulation.

    Science.gov (United States)

    Tapia, Evelina; Beck, Diane M

    2014-01-01

    A number of influential theories posit that visual awareness relies not only on the initial, stimulus-driven (i.e., feedforward) sweep of activation but also on recurrent feedback activity within and between brain regions. These theories of awareness draw heavily on data from masking paradigms in which visibility of one stimulus is reduced due to the presence of another stimulus. More recently transcranial magnetic stimulation (TMS) has been used to study the temporal dynamics of visual awareness. TMS over occipital cortex affects performance on visual tasks at distinct time points and in a manner that is comparable to visual masking. We draw parallels between these two methods and examine evidence for the neural mechanisms by which visual masking and TMS suppress stimulus visibility. Specifically, both methods have been proposed to affect feedforward as well as feedback signals when applied at distinct time windows relative to stimulus onset and as a result modify visual awareness. Most recent empirical evidence, moreover, suggests that while visual masking and TMS impact stimulus visibility comparably, the processes these methods affect may not be as similar as previously thought. In addition to reviewing both masking and TMS studies that examine feedforward and feedback processes in vision, we raise questions to guide future studies and further probe the necessary conditions for visual awareness.

  18. Design and simulations of a short optical baffle for the Lightweight Asymmetry and Magnetism Probe (LAMP)

    Science.gov (United States)

    Xing, Yujie; Wang, Zhanshan; Li, Wenbi; Yu, Jun; Feng, Hua

    2017-08-01

    The Lightweight Asymmetry and Magnetism Probe (LAMP) is a micro-satellite based mission concept for soft X-ray polarimetry at 250 eV with a large aperture but a short focal length. Due to the very low energy response of the gas pixel detector (GPD) used in LAMP, the stray light must be extremely attenuated. However, a long baffle is not favored for the micro-satellite with a limited geometry. In this paper, we propose a novel design having a short optical baffle but with high efficiency suppressing stray lights. For the optical aperture with a diameter of 700 mm used in LAMP, a short baffle of just 150 mm long can reduce the solar stray light by a factor better than 10-4 at the incidence angle larger than 60°, which is verified by simulations with TracePro ray-tracing software. This design meets the requirement for LAMP and the design concept should be helpful for other optical/UV/X-ray telescopes.

  19. Versatile variable temperature and magnetic field scanning probe microscope for advanced material research

    Science.gov (United States)

    Jung, Jin-Oh; Choi, Seokhwan; Lee, Yeonghoon; Kim, Jinwoo; Son, Donghyeon; Lee, Jhinhwan

    2017-10-01

    We have built a variable temperature scanning probe microscope (SPM) that covers 4.6 K-180 K and up to 7 T whose SPM head fits in a 52 mm bore magnet. It features a temperature-controlled sample stage thermally well isolated from the SPM body in good thermal contact with the liquid helium bath. It has a 7-sample-holder storage carousel at liquid helium temperature for systematic studies using multiple samples and field emission targets intended for spin-polarized spectroscopic-imaging scanning tunneling microscopy (STM) study on samples with various compositions and doping conditions. The system is equipped with a UHV sample preparation chamber and mounted on a two-stage vibration isolation system made of a heavy concrete block and a granite table on pneumatic vibration isolators. A quartz resonator (qPlus)-based non-contact atomic force microscope (AFM) sensor is used for simultaneous STM/AFM operation for research on samples with highly insulating properties such as strongly underdoped cuprates and strongly correlated electron systems.

  20. Probing the surface properties of a polymer glass with macroscopic friction

    International Nuclear Information System (INIS)

    Bureau, Lionel

    2007-01-01

    We show how macroscopic friction can be used as a sensitive probe of chain dynamics at the surface of a glassy polymer. We present experiments in which a smooth poly(methylmethacrylate) (PMMA) solid slides on flat surfaces presenting different densities of pinning sites available for polymer/substrate bond formation. These experiments indicate that: (i) at high pinning level, frictional dissipation occurs through the sudden flips of molecular-sized bistable regions localized in a nm-thick layer of confined chains, which responds to shear as an elasto-plastic solid, and (ii) in situations of weak pinning, dissipation appears to be governed by a process akin to that proposed for rubber friction. This suggests that some 'glass-to-rubber' transition occurs at the polymer surface when its interaction with the substrate goes from strong to weak. The temperature-dependence of friction provides further support for the presence of a nm-thick layer at the polymer surface, which exhibits a rubberlike response in situation of weak interaction with the countersurface. This behavior results from the interplay between viscous flow in this surface layer, and shear induced depinning of adsorbed surface chains. Moreover, a quantitative analysis of the results indicates that the pinning dynamics of polymer chains is controlled by localized β rotational motions at the interface

  1. Rain, winds and haze during the Huygens probe's descent to Titan's surface

    Science.gov (United States)

    Tomasko, M.G.; Archinal, B.; Becker, T.; Bezard, B.; Bushroe, M.; Combes, M.; Cook, D.; Coustenis, A.; De Bergh, C.; Dafoe, L.E.; Doose, L.; Doute, S.; Eibl, A.; Engel, S.; Gliem, F.; Grieger, B.; Holso, K.; Howington-Kraus, E.; Karkoschka, E.; Keller, H.U.; Kirk, R.; Kramm, R.; Kuppers, M.; Lanagan, P.; Lellouch, E.; Lemmon, M.; Lunine, J.; McFarlane, E.; Moores, J.; Prout, G.M.; Rizk, B.; Rosiek, M.; Rueffer, P.; Schroder, S.E.; Schmitt, B.; See, C.; Smith, P.; Soderblom, L.; Thomas, N.; West, R.

    2005-01-01

    The irreversible conversion of methane into higher hydrocarbons in Titan's stratosphere implies a surface or subsurface methane reservoir. Recent measurements from the cameras aboard the Cassini orbiter fail to see a global reservoir, but the methane and smog in Titan's atmosphere impedes the search for hydrocarbons on the surface. Here we report spectra and high-resolution images obtained by the Huygens Probe Descent Imager/Spectral Radiometer instrument in Titan's atmosphere. Although these images do not show liquid hydrocarbon pools on the surface, they do reveal the traces of once flowing liquid. Surprisingly like Earth, the brighter highland regions show complex systems draining into flat, dark lowlands. Images taken after landing are of a dry riverbed. The infrared reflectance spectrum measured for the surface is unlike any other in the Solar System; there is a red slope in the optical range that is consistent with an organic material such as tholins, and absorption from water ice is seen. However, a blue slope in the near-infrared suggests another, unknown constituent. The number density of haze particles increases by a factor of just a few from an altitude of 150 km to the surface, with no clear space below the tropopause. The methane relative humidity near the surface is 50 per cent. ?? 2005 Nature Publishing Group.

  2. Preparation, surface modification and microwave characterization of magnetic iron fibers

    Energy Technology Data Exchange (ETDEWEB)

    Nie Yan [Department of Electronic Science and Technology, Huazhong University of Science and Technology, Wuhan 430074 (China)]. E-mail: nieyanko@yahoo.com.cn; He Huahui [Department of Electronic Science and Technology, Huazhong University of Science and Technology, Wuhan 430074 (China); Zhao Zhenshen [Department of Electronic Science and Technology, Huazhong University of Science and Technology, Wuhan 430074 (China); Gong Rongzhou [Department of Electronic Science and Technology, Huazhong University of Science and Technology, Wuhan 430074 (China); Yu Hongbin [Department of optoelectronic Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2006-11-15

    In this paper, magnetic iron fibers of 3-10 {mu}m diameter and an adjustable aspect ratio were synthesized successfully by a method involving pyrolysis of carbonyl under a magnetic field. A surface modification technology was also investigated. The electromagnetic parameters of the iron-fiber-wax composites were measured using the transmission/reflection coaxial line method in the microwave frequency range of 2-18 GHz. The results show that the prepared iron-fiber-wax composites exhibit high magnetic loss that can be further improved after phosphating. On the other hand, the complex permittivity was significantly decreased after phosphating. As a result, this kind of iron fiber may be useful for thin and lightweight radar-absorbing materials.

  3. Crystallographic analysis of thin film surfaces using micro-probe reflexion high-energy electron diffraction

    International Nuclear Information System (INIS)

    Ichikawa, Masakazu; Doi, Takahisa; Hayakawa, Kazunobu

    1984-01-01

    Micro-probe reflexion high-energy electron diffraction using an electron beam having a 20nm beam diameter at a beam current of 8 nA, has been developed for performing crystallographic analyses of thin film and bulk crystal surfaces. High spatial resolution and high brightness have made it possible to perform analyses of thin films on substrates having fine structures without such sample preparation as thinning. A dark field imaging method using part of the diffraction spot intensity has also been developed. Using this method, it was found that atomic steps and dislocations on bulk and material-deposited Si surfaces can be observed. This shows the usefulness of the technique for studying crystal growth of thin films with mono-layer depth resolution. (author)

  4. Nanoscale surface photovoltage of organic semiconductors with two pass Kelvin probe microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Escasain, E; Colchero, J; Palacios-Lidon, E [Departamento Fisica, Facultad de Quimica (Campus Espinardo), Universidad de Murcia, E-30100 Murcia (Spain); Lopez-Elvira, E; Baro, A M, E-mail: elisapl@um.es [Instituto de Ciencia de Materiales de Madrid-CSIC, Campus de Cantoblanco, E-28049, Madrid (Spain)

    2011-09-16

    Kelvin probe microscopy implemented with controlled sample illumination is used to study nanoscale surface photovoltage effects. With this objective a two trace method, where each scanning line is measured with and without external illumination, is proposed. This methodology allows a direct comparison of the contact potential images acquired in darkness and under illumination and, therefore, the surface photovoltage is simply inferred. Combined with an appropriate data analysis, the temporal and spatial evolution of reversible and irreversible photo-induced processes can be obtained. The potential and versatility of this technique is applied to MEH-PPV thin films. Photo-physical phenomena such as the mesoscale polymer electronic light-induced response as well as the local nanoscale electro-optical properties are studied.

  5. The quantum magnetism of individual manganese-12-acetate molecular magnets anchored at surfaces.

    Science.gov (United States)

    Kahle, Steffen; Deng, Zhitao; Malinowski, Nikola; Tonnoir, Charlène; Forment-Aliaga, Alicia; Thontasen, Nicha; Rinke, Gordon; Le, Duy; Turkowski, Volodymyr; Rahman, Talat S; Rauschenbach, Stephan; Ternes, Markus; Kern, Klaus

    2012-01-11

    The high intrinsic spin and long spin relaxation time of manganese-12-acetate (Mn(12)) makes it an archetypical single molecular magnet. While these characteristics have been measured on bulk samples, questions remain whether the magnetic properties replicate themselves in surface supported isolated molecules, a prerequisite for any application. Here we demonstrate that electrospray ion beam deposition facilitates grafting of intact Mn(12) molecules on metal as well as ultrathin insulating surfaces enabling submolecular resolution imaging by scanning tunneling microscopy. Using scanning tunneling spectroscopy we detect spin excitations from the magnetic ground state of the molecule at an ultrathin boron nitride decoupling layer. Our results are supported by density functional theory based calculations and establish that individual Mn(12) molecules retain their intrinsic spin on a well chosen solid support. © 2011 American Chemical Society

  6. Multiparametric Kelvin Probe Force Microscopy for the Simultaneous Mapping of Surface Potential and Nanomechanical Properties.

    Science.gov (United States)

    Xie, Hui; Zhang, Hao; Hussain, Danish; Meng, Xianghe; Song, Jianmin; Sun, Lining

    2017-03-21

    We report high-resolution multiparametric kelvin probe force microscopy (MP-KPFM) measurements for the simultaneous quantitative mapping of the contact potential difference (CPD) and nanomechanical properties of the sample in single-pass mode. This method combines functionalities of the force-distance-based atomic force microscopy and amplitude-modulation (AM) KPFM to perform measurements in single-pass mode. During the tip-sample approach-and-retract cycle, nanomechanical measurements are performed for the retract part of nanoindentation, and the CPD is measured by the lifted probe with a constant tip-sample distance. We compare the performance of the proposed method with the conventional KPFMs by mapping the CPD of multilayer graphene deposited on n-doped silicon, and the results demonstrate that MP-KPFM has comparable performance to AM-KPFM. In addition, the experimental results of a custom-fabricated polymer grating with heterogeneous surfaces validate the multiparametric imaging capability of the MP-KPFM. This method can have potential applications in finding the inherent link between nanomechanical properties and the surface potential of the materials, such as the quantification of the electromechanical response of the deformed piezoelectric materials.

  7. Gapless Fermi Surfaces in anisotropic multiband superconductors in magnetic field.

    Science.gov (United States)

    Barzykin, Victor; Gor'kov, Lev P.

    2007-03-01

    We propose that a new state with a fully gapless Fermi surface appears in quasi-2D multiband superconductors in magnetic field applied parallel to the plane. It is characterized by a paramagnetic moment caused by a finite density of states on the open Fermi surface. We calculate thermodynamic and magnetic properties of the gapless state for both s-wave and d-wave cases, and discuss the details of the 1-st order metamagnetic phase transition that accompanies the appearance of the new phase in s-wave superconductors. We suggest possible experiments to detect this state both in the s-wave (2-H NbSe2) and d-wave (CeCoIn5) superconductors.

  8. Statistical Analysis of Magnetic Abrasive Finishing (MAF) On Surface Roughness

    Science.gov (United States)

    Givi, Mehrdad; Tehrani, Alireza Fadaei; Mohammadi, Aminollah

    2010-06-01

    Magnetic assisted finishing is one of the nontraditional methods of polishing that recently has been attractive for the researchers. This paper investigates the effects of some parameters such as rotational speed of the permanent magnetic pole, work gap between the permanent pole and the work piece, number of the cycles and the weight of the abrasive particles on aluminum surface plate finishing. The three levels full factorial method was used as the DOE technique (design of experiments) for studying the selected factors. Analysis of Variance (ANOVA) has been used to determine significant factors and also to obtain an equation based on data regression. Experimental results indicate that for a change in surface roughness ΔRa, number of cycles and working gap are found to be the most significant parameters followed by rotational speed and then weight of powders.

  9. Folic acid-targeted magnetic Tb-doped CeF3 fluorescent nanoparticles as bimodal probes for cellular fluorescence and magnetic resonance imaging.

    Science.gov (United States)

    Ma, Zhi-Ya; Liu, Yu-Ping; Bai, Ling-Yu; An, Jie; Zhang, Lin; Xuan, Yang; Zhang, Xiao-Shuai; Zhao, Yuan-Di

    2015-10-07

    Magnetic fluorescent nanoparticles (NPs) have great potential applications for diagnostics, imaging and therapy. We developed a facile polyol method to synthesize multifunctional Fe3O4@CeF3:Tb@CeF3 NPs with small size (imaging agents for simultaneous in vitro targeted fluorescence imaging and magnetic resonance imaging (MRI) of HeLa cells with overexpressed folate receptors (FR). The results indicated that these NPs had strong luminescence and enhanced T2-weighted MR contrast and would be promising candidates as multimodal probes for both fluorescence and MRI imaging.

  10. Virus-based surface patterning of biological molecules, probes, and inorganic materials.

    Science.gov (United States)

    Ahn, Suji; Jeon, Seongho; Kwak, Eun-A; Kim, Jong-Man; Jaworski, Justyn

    2014-10-01

    An essential requirement for continued technological advancement in many areas of biology, physics, chemistry, and materials science is the growing need to generate custom patterned materials. Building from recent achievements in the site-specific modification of virus for covalent surface tethering, we show in this work that stable 2D virus patterns can be generated in custom geometries over large area glass surfaces to yield templates of biological, biochemical, and inorganic materials in high density. As a nanomaterial building block, filamentous viruses have been extensively used in recent years to produce materials with interesting properties, owing to their ease of genetic and chemical modification. By utilizing un-natural amino acids generated at specific locations on the filamentous fd bacteriophage protein coat, surface immobilization is carried out on APTES patterned glass resulting in precise geometries of covalently linked virus material. This technique facilitated the surface display of a high density of virus that were labeled with biomolecules, fluorescent probes, and gold nanoparticles, thereby opening the possibility of integrating virus as functional components for surface engineering. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Magnetic surface compression heating in the heliotron device

    International Nuclear Information System (INIS)

    Uo, K.; Motojima, O.

    1982-01-01

    The slow adiabatic compression of the plasma in the heliotron device is examined. It has a prominent characteristic that the plasma equilibrium always exists at each stage of the compression. The heating efficiency is calculated. We show the possible access to fusion. A large amount of the initial investment for the heating system (NBI or RF) is reduced by using the magnetic surface compression heating. (author)

  12. Fluorescent Magnetic Bioprobes by Surface Modification of Magnetite Nanoparticles

    OpenAIRE

    Pinheiro, Paula C.; Daniel-da-Silva, Ana L.; Tavares, Daniela S.; Calatayud, M. Pilar; Goya, Gerardo F.; Trindade, Tito

    2013-01-01

    Bimodal nanoprobes comprising both magnetic and optical functionalities have been prepared via a sequential two-step process. Firstly, magnetite nanoparticles (MNPs) with well-defined cubic shape and an average dimension of 80 nm were produced by hydrolysis of iron sulfate and were then surface modified with silica shells by using the sol-gel method. The Fe3O4@SiO2 particles were then functionalized with the fluorophore, fluorescein isothiocyanate (FITC), mediated by assembled shells of the c...

  13. Plasmas fluxes to surfaces for an oblique magnetic field

    International Nuclear Information System (INIS)

    Pitcher, C.S.; Stangeby, P.C.; Elder, J.D.; Bell, M.G.; Kilpatrick, S.J.; Manos, D.M.; Medley, S.S.; Owens, D.K.; Ramsey, A.T.; Ulrickson, M.

    1992-07-01

    The poloidal and toroidal spatial distributions of D α , He I and C II emission have been obtained in the vicinity of the TFTR bumper limiter and are compared with models of ion flow to the surface. The distributions are found not to agree with a model (the ''Cosine'' model) which determines the incident flux density using only the parallel fluxes in the scrape-off layer and the projected area of the surface perpendicular to the field lines. In particular, the Cosine model is not able to explain the significant fluxes observed at locations on the surface which are oblique to the magnetic field. It is further shown that these fluxes cannot be explained by the finite Larmor radius of impinging ions. Finally, it is demonstrated, with the use of Monte Carlo codes, that the distributions can be explained by including both parallel and cross-field transport onto the limiter surface

  14. Nanoscale x-ray magnetic circular dichroism probing of electric-field-induced magnetic switching in multiferroic nanostructures

    Science.gov (United States)

    Zhao, T.; Scholl, A.; Zavaliche, F.; Zheng, H.; Barry, M.; Doran, A.; Lee, K.; Cruz, M. P.; Ramesh, R.

    2007-03-01

    The magnetic structure as well as its response to an external electric field were studied in ferrimagnetic CoFe2O4 nanopillars embedded in an epitaxial ferroelectric BiFeO3 film using photoemission electron microscopy and x-ray magnetic circular dichroism. Magnetic switching was observed in both Co and Fe magnetic sublattices after application of an electric field. About 50% of the CoFe2O4 nanopillars were measured to switch their magnetization with the electric field, implying an elastic-mediated electric-field-induced magnetic anisotropy change.

  15. Adhesion and friction of polymer surfaces studied using scanning probe microscopy

    Science.gov (United States)

    Moon, Seung-Ho

    2003-10-01

    Scanning Probe Microscopy has been utilized to investigate the nanomechanical and nanorheological properties at the surface of polymers and polymer blends. To study the surface behavior in detail, it is critical that the SPM instrument have sufficient flexibility. A temperature stage and environmental chamber have been implemented and measurement automation has been achieved using a high-speed data acquisition system controlled by LabView(TM). Finally, new measurement protocols, "X-modulation" and "Force-Distance with X-modulation", have been developed. First measurements using those techniques have been performed for the study of aged model pressure sensitive adhesives. It has been found that the magnitude of the lateral force is so sensitive to adhesion force that X-modulation can identify qualitative differences in the strength of surface stickiness. Variations in surface adhesiveness with humidity are more obvious when the tackifier is present. A large lateral force and strongly reduced stiffness, measured using F-d with X-modulation, have been observed at high humidity for the homogeneous, hydrophilic surface of the adhesive loaded with 60wt% tackifier. These observations are consistent with a model that envisions a tackifier-enriched region near the surface. A large creep effect has also been observed for this sample, and the creep effect is magnified with temperature. These results are consistent with the hypothesis that at a hydrophilic adhesive surface water molecules may strongly alter the surface-tip interactions or modify the mechanical properties of the material nearest the surface. By changing the Z-loading velocity, dynamic adhesion behavior has been investigated. The mechanism of adhesive failure have been elucidated by comparing the velocity dependence of pull-off force and lateral force. Since this dynamic measurement is sensitive to the material composition at the surface, it has been utilized to study the surface segregation of one component at

  16. Probing the Dynamics of Cellular Traction Forces with Magnetic Micropost Arrays

    Science.gov (United States)

    Kramer, Corinne; Chen, Christopher; Reich, Daniel

    2009-03-01

    Mechanical forces on living cells are associated with changes in cellular function. For example, vascular smooth muscle cells are known to undergo a mechanical feedback response to increased stress, which can result in atherosclerosis. We have recently developed a magnetic micropost array, a novel device for measuring cellular traction forces that simultaneously enables the application of localized external forces to cells. The device consists of an array of micrometer scale elastomeric posts that act as force sensors for cells cultured on their tips. An external force is applied to the adherent surface of a cell via a magnetic torque on a cobalt nanowire embedded in a single post. Initial results showed an active and non-local cellular response to applied forces in mouse fibroblast cells.ootnotetextN. Sniadecki, et. al, Proc Natl Acad Sci, 104, 14553 (2007). We will present results on the spatially resolved dynamics of traction forces exerted by smooth muscle cells over time in response to constant and time-varying stimulation. The observation of biochemical and mechanical regulation of the subcellular redistribution of force may allow insights into cellular mechanotransduction and control of cell function.

  17. Probing surface plasmons in individual Ag nanoparticles in the ultra-violet spectral regime.

    Science.gov (United States)

    Chu, Ming-Wen; Sharma, Pradeep; Chang, Ching-Pin; Liou, Sz Chian; Tsai, Kun-Tong; Wang, Juen-Kai; Wang, Yuh-Lin; Chen, Cheng Hsuan

    2009-06-10

    Previous investigations of surface plasmons in Ag largely focused on their excitations in the visible spectral regime. Using scanning transmission electron microscopy with an electron beam of 0.2 nm in conjunction with electron energy-loss spectroscopy, we spectrally and spatially probe the surface plasmons in individual Ag nanoparticles (approximately 30 nm), grown on Si, in the ultra-violet spectral regime. The nanomaterials show respective sharp and broad surface-plasmon resonances at approximately 3.5 eV (approximately 355 nm) and approximately 7.0 eV (approximately 177 nm), and the correlated spectral calculations established their multipolar characteristics. The near-field distributions of the surface plasmons on the nanoparticles were also mapped out, revealing the predominant dipolar nature of the 3.5 eV excitation with obvious near-field enhancements at one end of the nano-object. The unveiled near-field enhancements have potential applications in plasmonics and molecular sensing.

  18. Probing surface plasmons in individual Ag nanoparticles in the ultra-violet spectral regime

    International Nuclear Information System (INIS)

    Chu, M-W; Chang, C-P; Liou, S C; Wang, J-K; Chen, C H; Sharma, Pradeep; Tsai, K-T; Wang, Y-L

    2009-01-01

    Previous investigations of surface plasmons in Ag largely focused on their excitations in the visible spectral regime. Using scanning transmission electron microscopy with an electron beam of 0.2 nm in conjunction with electron energy-loss spectroscopy, we spectrally and spatially probe the surface plasmons in individual Ag nanoparticles (∼30 nm), grown on Si, in the ultra-violet spectral regime. The nanomaterials show respective sharp and broad surface-plasmon resonances at ∼3.5 eV (∼355 nm) and ∼7.0 eV (∼177 nm), and the correlated spectral calculations established their multipolar characteristics. The near-field distributions of the surface plasmons on the nanoparticles were also mapped out, revealing the predominant dipolar nature of the 3.5 eV excitation with obvious near-field enhancements at one end of the nano-object. The unveiled near-field enhancements have potential applications in plasmonics and molecular sensing.

  19. Impurity scattering and magnetic field influence on a nodal surface of a d-wave superconductor

    Energy Technology Data Exchange (ETDEWEB)

    Zare, Aida

    2012-02-17

    peak height has a nonmonotonous temperature dependence. Considering the Born impurity scattering in the presence of an external magnetic field, we show that the peak height in the local density of states at the surface is strongly reduced due to the scattering rate. The peak width also grows with decreasing mean-free path. However, the size of the peak splitting remains almost unaffected. The presence of the surface ABSs also has a significant influence on the nonlinear Meissner effect. The nonlinear response coefficient in the bulk of a d-wave superconductor is known to show an upturn at low temperatures following a 1/T law in a clean system. However we show that the contribution of the surface ABSs to the nonlinear response coefficient follows an inverse T-cube law, which will ultimately dominate. Considering the total inductance, a quantity which actually is probed in typical intermodulation experiments, we show that the crossover from bulk dominated behavior to surface dominated behavior occurs at a comparatively high temperature. Also at this point the nonlinear coefficient changes the sign. Such temperatures are readily available in intermodulation experiments and make them a tool to study surface ABSs. Furthermore, in order to check the validity of the numerical calculations and obtain a physical understanding of the results, we present a model to solve the problem analytically.

  20. Quantum phase transitions and local magnetism in Mott insulators: A local probe investigation using muons, neutrons, and photons

    Science.gov (United States)

    Frandsen, Benjamin A.

    Mott insulators are materials in which strong correlations among the electrons induce an unconventional insulating state. Rich interplay between the structural, magnetic, and electronic degrees of freedom resulting from the electron correlation can lead to unusual complexity of Mott materials on the atomic scale, such as microscopically heterogeneous phases or local structural correlations that deviate significantly from the average structure. Such behavior must be studied by suitable experimental techniques, i.e. "local probes", that are sensitive to this local behavior rather than just the bulk, average properties. In this thesis, I will present results from our studies of multiple families of Mott insulators using two such local probes: muon spin relaxation (muSR), a probe of local magnetism; and pair distribution function (PDF) analysis of x-ray and neutron total scattering, a probe of local atomic structure. In addition, I will present the development of magnetic pair distribution function analysis, a novel method for studying local magnetic correlations that is highly complementary to the muSR and atomic PDF techniques. We used muSR to study the phase transition from Mott insulator to metal in two archetypal Mott insulating systems: RENiO3 (RE = rare earth element) and V2O3. In both of these systems, the Mott insulating state can be suppressed by tuning a nonthermal parameter, resulting in a "quantum" phase transition at zero temperature from the Mott insulating state to a metallic state. In RENiO3, this occurs through variation of the rare-earth element in the chemical composition; in V 2O3, through the application of hydrostatic pressure. Our results show that the metallic and Mott insulating states unexpectedly coexist in phase-separated regions across a large portion of parameter space near the Mott quantum phase transition and that the magnitude of the ordered antiferromagnetic moment remains constant across the phase diagram until it is abruptly

  1. Direct surface magnetometry with photoemission magnetic x-ray dichroism

    Energy Technology Data Exchange (ETDEWEB)

    Tobin, J.G.; Goodman, K.W. [Lawrence Berkeley National Lab., CA (United States); Schumann, F.O. [Pennsylvania State Univ., University Park, PA (United States)] [and others

    1997-04-01

    Element specific surface magnetometry remains a central goal of synchrotron radiation based studies of nanomagnetic structures. One appealing possibility is the combination of x-ray absorption dichroism measurements and the theoretical framework provided by the {open_quotes}sum rules.{close_quotes} Unfortunately, sum rule analysis are hampered by several limitations including delocalization of the final state, multi-electronic phenomena and the presence of surface dipoles. An alternative experiment, Magnetic X-Ray Dichroism in Photoelectron Spectroscopy, holds out promise based upon its elemental specificity, surface sensitivity and high resolution. Computational simulations by Tamura et al. demonstrated the relationship between exchange and spin orbit splittings and experimental data of linear and circular dichroisms. Now the authors have developed an analytical framework which allows for the direct extraction of core level exchange splittings from circular and linear dichroic photoemission data. By extending a model initially proposed by Venus, it is possible to show a linear relation between normalized dichroism peaks in the experimental data and the underlying exchange splitting. Since it is reasonable to expect that exchange splittings and magnetic moments track together, this measurement thus becomes a powerful new tool for direct surface magnetometry, without recourse to time consuming and difficult spectral simulations. The theoretical derivation will be supported by high resolution linear and circular dichroism data collected at the Spectromicroscopy Facility of the Advanced Light Source.

  2. Cleaning of magnetic nanoparticle surfaces via cold plasmas treatments

    Directory of Open Access Journals (Sweden)

    Narayan Poudyal

    2017-05-01

    Full Text Available We report surface cleaning of magnetic nanoparticles (SmCo5 nanochips and CoFe2O4 nanoparticles by using cold plasma. SmCo5 nanochips and CoFe2O4 nanoparticles, coated with surfactants (oleic acid and oleylamine, respectively on their surfaces, were treated in cold plasmas generated in argon, hydrogen or oxygen atmospheres. The plasmas were generated using a capacitively coupled pulsed radio frequency discharge. Surface cleaning of nanoparticles was monitored by measurement of the reduction of surface carbon content as functions of plasma processing parameters and treatment times. EDX and XPS analyses of the nanoparticles, obtained after the plasma treatment, revealed significant reduction of carbon content was achieved via plasma treatment. The SmCo5 nanochips and CoFe2O4 nanoparticles treated in an argon plasma revealed reduction of atomic carbon content by more than 54 and 40 in atomic percentage, compared with the untreated nanoparticles while the morphology, crystal structures and magnetic properties are retained upon the treatments.

  3. Direct surface magnetometry with photoemission magnetic x-ray dichroism

    International Nuclear Information System (INIS)

    Tobin, J.G.; Goodman, K.W.; Schumann, F.O.

    1997-01-01

    Element specific surface magnetometry remains a central goal of synchrotron radiation based studies of nanomagnetic structures. One appealing possibility is the combination of x-ray absorption dichroism measurements and the theoretical framework provided by the open-quotes sum rules.close quotes Unfortunately, sum rule analysis are hampered by several limitations including delocalization of the final state, multi-electronic phenomena and the presence of surface dipoles. An alternative experiment, Magnetic X-Ray Dichroism in Photoelectron Spectroscopy, holds out promise based upon its elemental specificity, surface sensitivity and high resolution. Computational simulations by Tamura et al. demonstrated the relationship between exchange and spin orbit splittings and experimental data of linear and circular dichroisms. Now the authors have developed an analytical framework which allows for the direct extraction of core level exchange splittings from circular and linear dichroic photoemission data. By extending a model initially proposed by Venus, it is possible to show a linear relation between normalized dichroism peaks in the experimental data and the underlying exchange splitting. Since it is reasonable to expect that exchange splittings and magnetic moments track together, this measurement thus becomes a powerful new tool for direct surface magnetometry, without recourse to time consuming and difficult spectral simulations. The theoretical derivation will be supported by high resolution linear and circular dichroism data collected at the Spectromicroscopy Facility of the Advanced Light Source

  4. Superconducting magnetic control system for manipulation of particulate matter and magnetic probes in medical and industrial applications

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Yung Sheng; Hull, John R.; Askew, Thomas R.

    2006-07-11

    A system and method of controlling movement of magnetic material with at least first and second high temperature superconductors at spaced locations. A plurality of solenoids are associated with the superconductors to induce a persistent currents in preselected high temperature superconductors establishing a plurality of magnetic fields in response to pulsed currents introduced to one or more of the solenoids. Control mechanism in communication with said solenoids and/or said high temperature superconductors are used to demagnetize selected ones of the high temperature superconductors to reduce the magnetic fields substantially to zero. Magnetic material is moved between magnetic fields by establishing the presence thereof and thereafter reducing magnetic fields substantially to zero and establishing magnetic fields in other superconductors arranged in a predetermined configuration.

  5. Ab initio STM and STS simulations on magnetic and nonmagnetic metallic surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Dick, Alexey

    2008-04-14

    The aim of this work was to provide an in-depth understanding of a new generation of scan- ning tunneling microscopy experiments, performed employing different regimes of the STM: the spectroscopy-mode (the so-called Fourier Transformed STM, FT-STM), and the spin-sensitive mode (the so-called spin-polarized STM, SP-STM). In the present thesis ab initio tools are proposed that are based on DFT calculations to theoretically predict and analyze such types of the STM. The first part of this thesis focusses on the simulation of FT-STM, the mode that allows to probe local dispersion properties of the electrons at the surface. In order to provide the theoretical counterpart of the experimental FT-STM spectra we have introduced a new implicit approach that is derived from Tersoff-Hamann theory of the STM. The importance of an accurate description of surface wavefunctions at 5-15 A above the surface as well as the spurious quantum- size effects have been discussed in detail together with approaches to obtain converged FT-STM images. We applied our method to FT-STM experiments performed on Ag(110) surfaces. In the second part of the thesis we discuss the modeling of the spin-resolved STM, the mode that allows to characterize the magnetic structure of a surface. As a case system we studied here the magnetically-ordered transition-metal nitride surface Mn{sub 3}N{sub 2}(010). Because SP-STM experiments did not allow a conclusive understanding of the surface structure, we have first employed ab initio thermodynamics to figure out the most stable magnetic and atomic configuration of the surface that are consistent with experiments. To simulate SP-STM images on the most stable Mn{sub 3}N{sub 2}(010) surface we have employed the spin-generalized transfer-Hamiltonian formalism, assuming that the tip wavefunctions have dominant radial symmetry (s-like tip). (orig.)

  6. Unidirectional edge modes launched by surface fluctuation in magnetic metamaterials

    Science.gov (United States)

    Chen, Huajin; Luo, Youzhu; Liang, Chenghua; Li, Zhenglin; Liu, Shiyang; Lin, Zhifang

    2018-03-01

    We demonstrate theoretically that the surface fluctuation can be used to launch the unidirectional electromagnetic edge mode for a Gaussian beam incident normal to the magnetic metamaterials (MMs) composed of an array of ferrite rods with the uppermost layer introduced position or size fluctuation in the coupling region. Such an edge mode is solely allowed to propagate in one direction due to the time-reversal symmetry breaking in MMs under the exertion of an external magnetic field, and it is substantially enhanced by the magnetic surface plasmon resonance. The nonreciprocal excitation of the edge states can also be understood by examining the scattering amplitudes of different partial waves, which indicate that the 1st order of the angular momentum channel plays a crucial role in realizing the nonreciprocity. The present research might be significant for the implementation of unidirectional absorption and the reexamination of bound states in the continuum in the context of MMs. In addition, the unique optical property can be exploited to design electromagnetic waveguide devices, such as one-way waveguide and wave bender, which are strongly robust against the obstacles placed in the channel of designed devices, facilitating to realize optical integrated circuits.

  7. Design of a triple resonance magic angle sample spinning probe for high field solid state nuclear magnetic resonance

    Science.gov (United States)

    Martin, Rachel W.; Paulson, Eric K.; Zilm, Kurt W.

    2003-06-01

    Standard design and construction practices used in building nuclear magnetic resonance (NMR) probes for the study of solid state samples become difficult if not entirely impractical to implement as the 1H resonance frequency approaches the self resonance frequency of commercial capacitors. We describe an approach that utilizes short variable transmission line segments as tunable reactances. Such an approach effectively controls stray reactances and provides a higher Q alternative to ceramic chip capacitors. The particular probe described is built to accommodate a 2.5 mm magic angle spinning rotor system, and is triply tuned to 13C, 15N, and 1H frequencies for use at 18.8 T (200, 80, and 800 MHz, respectively). Isolation of the three radio frequency (rf) channels is achieved using both a rejection trap and a transmission line notch filter. The compact geometry of this design allows three channels with high power handling capability to fit in a medium bore (63 mm) magnet. Extended time variable temperature operation is integral to the mechanical design, enabling the temperature control necessary for investigation of biological macromolecules. Accurate measurement of the air temperature near the sample rotor is achieved using a fiber optic thermometer, which does not interfere with the rf electronics. We also demonstrate that acceptable line shapes are only readily achieved using zero magnetic susceptibility wire in construction of the sample coil. Computer simulation of the circuit aided in the physical design of the probe. Representative data illustrating the efficiency, rf homogeneity, and signal to noise factor of the probe are presented.

  8. Surface topography acquisition method for double-sided near-right-angle structured surfaces based on dual-probe wavelength scanning interferometry.

    Science.gov (United States)

    Zhang, Tao; Gao, Feng; Jiang, Xiangqian

    2017-10-02

    This paper proposes an approach to measure double-sided near-right-angle structured surfaces based on dual-probe wavelength scanning interferometry (DPWSI). The principle and mathematical model is discussed and the measurement system is calibrated with a combination of standard step-height samples for both probes vertical calibrations and a specially designed calibration artefact for building up the space coordinate relationship of the dual-probe measurement system. The topography of the specially designed artefact is acquired by combining the measurement results with white light scanning interferometer (WLSI) and scanning electron microscope (SEM) for reference. The relative location of the two probes is then determined with 3D registration algorithm. Experimental validation of the approach is provided and the results show that the method is able to measure double-sided near-right-angle structured surfaces with nanometer vertical resolution and micrometer lateral resolution.

  9. Planck intermediate results XXXV. Probing the role of the magnetic field in the formation of structure in molecular clouds

    DEFF Research Database (Denmark)

    Ade, P. A. R.; Aghanim, N.; Alves, M. I. R.

    2016-01-01

    Within ten nearby (d molecular clouds we evaluate statistically the relative orientation between the magnetic field projected on the plane of sky, inferred from the polarized thermal emission of Galactic dust observed by Planck at 353 GHz, and the gas column density structures...... with increasing N-H, from mostly parallel or having no preferred orientation to mostly perpendicular. In simulations of magnetohydrodynamic turbulence in molecular clouds this trend in relative orientation is a signature of Alfvenic or sub-Alfvenic turbulence, implying that the magnetic field is significant...... for the gas dynamics at the scales probed by Planck. We compare the deduced magnetic field strength with estimates we obtain from other methods and discuss the implications of the Planck observations for the general picture of molecular cloud formation and evolution....

  10. Surface impedance of travelling--Wave antenna in magnetized plasma

    International Nuclear Information System (INIS)

    Denisenko, I.B.; Ostrikov, K.N.

    1993-01-01

    Wave properties of metal antennas immersed in a magnetoactive plasma are intensively studied nowadays with the objects of radio communications in ionosphere, plasma heating, gas discharge technique. Many papers are devoted to studies of sheath waves (SW) in magnetoplasma, which are surface by nature and propagate along the metal-low-density sheath-plasma waveguide structure. The results of these papers suggest that the existence of these waves makes significant contribution in antenna impedance. Note that the impedance measurement is one of possible ways of experimental surface waves characterization. In the present report the surface impedance of travelling SW antenna immersed in magnetoactive plasma is calculated and its dependence on the waveguide structure parameters such as plasma density, external magnetic field H 0 and electrons collisional frequency values, sheath region width, conductivity of metal surface is studied. The calculations have been carried out in a quasiplane approximation, when antenna radius greatly exceeds the SW skin depth. Note that the finite conductivity of metal is necessary to be taken into account to provide a finite surface impedance value. The surface impedance is calculated in two cases, namely when SW propagate along (Ζ parallel ) and across (Ζ perpendicular ) the external magnetic field. The relation between the values Ζ parallel and Ζ perpendicular is obtained. This relation shows that the values Ζ parallel and Ζ parallel may satisfy both inequalities Ζ parallel much-gt Ζ perpendicular and Ζ perpendicular approx-gt Ζ perpendicular dependent on the parameters of the structure. The comparison of dispersion properties of the SW propagating along Η 0 with the experimental results is carried out. The results are shown to satisfactorily correspond to the experimental results

  11. Magnetically Filtered Faraday Probe for Measuring the Ion Current Density Profile of a Hall Thruster

    National Research Council Canada - National Science Library

    Rovey, Joshua L; Walker, Mitchell L. R; Gallimore, Alec D; Peterson, Peter Y

    2006-01-01

    .... In this study, a MFFP, Faraday probe with a reduced acceptance angle (BFP), and nude Faraday probe are used to measure the ion current density profile of a 5 kW Hall thruster operating over the range of 300-500 V and 5-10 mg...

  12. Surface magnetic phase transitions in Dy/Lu superlattices

    International Nuclear Information System (INIS)

    Goff, J.P.; Sarthour, R.S.; Micheletti, C.; Langridge, S.; Wilkins, C.J.T.; Ward, R.C.C.; Wells, M.R.

    1999-01-01

    Dy/Lu superlattices comprising ferromagnetic Dy blocks coupled antiferromagnetically across the Lu blocks may be modelled as a chain of XY spins with antiferromagnetic exchange and six-fold anisotropy. We have calculated the stable magnetic phases for the cases of large anisotropy and a field applied along an easy direction. For an infinite chain an intermediate phase (1, 5,...) is predicted, where the notation gives the angle between the moment and the applied field in units of π/3. Furthermore, the effects of surface reconstruction are determined for finite chains. A [Dy 20 Lu 12 ] 20 superlattice has been studied using bulk magnetization and polarized neutron reflectivity. The (1, 5,...) phase has been identified and the results provide direct evidence in support of the theoretical predictions. Dipolar forces are shown to account for the magnitude of the observed exchange coupling. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  13. Ab initio theory of magnetic interactions at surfaces

    International Nuclear Information System (INIS)

    Sousa, C; Graaf, C de; Lopez, N; Harrison, N M; Illas, F

    2004-01-01

    The low to high spin energy transition of Ni adsorbed on regular and defective sites of MgO(100) and the relative strengths of bulk and surface magnetic coupling constants of first row transition metal oxides (MnO, FeO, CoO, NiO and CuO) are taken as examples to illustrate some deficiencies of density functional theory (DFT). For these ionic systems a cluster/periodic comparison within the same computational method (either DFT or Hartree-Fock) is used to establish that embedded cluster models provide an adequate representation. The cluster model approach is then used to obtain accurate values for the magnetic properties of interest by using explicitly correlated wavefunction methods which handle the electronic open shell rigorously as spin eigenfunctions

  14. Surface segregations in amorphous magnetically soft alloy under oxidation

    International Nuclear Information System (INIS)

    Bayankin, V.A.; Vasil'ev, V.Yu.; Volkova, I.B.; Skvortsova, N.G.; Smirnova, O.I.

    1997-01-01

    Using the Auger electron spectroscopy and electron reflecting diffraction the effects of high temperature annealing and electro-chemical treatment on chemical composition and atomic structure of amorphous magnetically soft alloy Co 57 Fe 5 Ni 10 Si 11 B 7 were investigated. It is shown the surface layers on the base of silicon carbide are formed during annealing while during electro-chemical treatment a cobalt borides are formed. Besides, during electro-chemical treatment the amorphous structure with different interatomic space are saved depending on time. At the time, mechanical properties of the alloy are not worse and it may be used for manufacturing of magnetodrives from amorphous magnetically soft materials [ru

  15. Reversal of atomic contrast in scanning probe microscopy on (111) metal surfaces

    Czech Academy of Sciences Publication Activity Database

    Ondráček, Martin; González, C.; Jelínek, Pavel

    2012-01-01

    Roč. 24, 08 (2012), 084003/1-084003/7 ISSN 0953-8984 R&D Projects: GA ČR(CZ) GPP204/11/P578; GA ČR GAP204/10/0952; GA ČR GA202/09/0545; GA MŠk(CZ) ME10076 Grant - others:AVČR(CZ) M100100904 Institutional research plan: CEZ:AV0Z10100521 Keywords : atomic force microscopy * metallic surfaces * atomic contrast * scanning tunneling microscopy Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.355, year: 2012 http://iopscience.iop.org/0953-8984/24/8/084003

  16. Epitaxial growth of pentacene on alkali halide surfaces studied by Kelvin probe force microscopy.

    Science.gov (United States)

    Neff, Julia L; Milde, Peter; León, Carmen Pérez; Kundrat, Matthew D; Eng, Lukas M; Jacob, Christoph R; Hoffmann-Vogel, Regina

    2014-04-22

    In the field of molecular electronics, thin films of molecules adsorbed on insulating surfaces are used as the functional building blocks of electronic devices. Control of the structural and electronic properties of the thin films is required for reliably operating devices. Here, noncontact atomic force and Kelvin probe force microscopies have been used to investigate the growth and electrostatic landscape of pentacene on KBr(001) and KCl(001) surfaces. We have found that, together with molecular islands of upright standing pentacene, a new phase of tilted molecules appears near step edges on KBr. Local contact potential differences (LCPD) have been studied with both Kelvin experiments and density functional theory calculations. Our images reveal that differently oriented molecules display different LCPD and that their value is independent of the number of molecular layers. These results point to the formation of an interface dipole, which may be explained by a partial charge transfer from the pentacene to the surface. Moreover, the monitoring of the evolution of the pentacene islands shows that they are strongly affected by dewetting: Multilayers build up at the expense of monolayers, and in the Kelvin images, previously unknown line defects appear, which reveal the epitaxial growth of pentacene crystals.

  17. Probing protein: DNA interactions using a uniform monolayer of DNA and surface plasmon resonance

    Science.gov (United States)

    Shumaker-Parry, Jennifer S.; Campbell, Charles T.; Stormo, Gary D.; Silbaq, Fauzi S.; Aebersold, Rudolf H.

    2000-04-01

    A method is described for immobilizing double-stranded DNAs to a planar gold surface with high density and uniform spacing. This is accomplished by adsorbing biotinylated DNAs onto a nearly close-packed monolayer of the protein streptavidin. This streptavidin monolayer, which offers approximately 5 X 1012 biotin sites per cm2, is prepared first by adsorbing it onto a mixed self-assembled monolayer on gold which contains biotin-terminated and oligo-terminated alkylthiolates in a 3/7 ratio. This DNA- functionalized surface resists non-specific protein adsorption and is useful for probing the kinetics and equilibrium binding of proteins to DNA with surface plasmon resonance. This is demonstrated with the Mnt protein, which is found to bind in 3.8:1 ratio to its immobilized DNA operator sequence. This is consistent with its behavior in homogeneous solution, where it binds as a tetramer to its DNA. A sequence with a single base-pair mutation shows nearly as much Mnt binding, but a completely random DNA sequence shows only 5 percent of this binding. This proves that DNA-binding proteins bind sequence-specifically to double-stranded DNAs which are immobilized to gold with this streptavidin linker layer.

  18. Characterization of local hydrophobicity on sapphire (0001) surfaces in aqueous environment by colloidal probe atomic force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Wada, Tomoya; Yamazaki, Kenji; Isono, Toshinari; Ogino, Toshio, E-mail: ogino-toshio-rx@ynu.ac.jp

    2017-02-28

    Highlights: • Local hydrophobicity of phase-separated sapphire (0001) surfaces was investigated. • These surfaces are featured by coexistence of hydrophilic and hydrophobic domains. • Each domain was characterized by colloidal probe atomic force microscopy in water. • Both domains can be distinguished by adhesive forces of the probe to the surfaces. • Characterization in aqueous environment is important in bio-applications of sapphire. - Abstract: Sapphire (0001) surfaces exhibit a phase-separation into hydrophobic and hydrophilic domains upon high-temperature annealing, which were previously distinguished by the thickness of adsorbed water layers in air using atomic force microscopy (AFM). To characterize their local surface hydrophobicity in aqueous environment, we used AFM equipped with a colloidal probe and measured the local adhesive force between each sapphire domain and a hydrophilic SiO{sub 2} probe surface, or a hydrophobic polystyrene one. Two data acquisition modes for statistical analyses were used: one is force measurements at different positions of the surface and the other repeated measurement at a fixed position. We found that adhesive force measurements using the polystyrene probe allow us to distinctly separate the hydrophilic and hydrophobic domains. The dispersion in the force measurement data at different positions of the surface is larger than that in the repeated measurements at a fixed position. It indicates that the adhesive force measurement is repeatable although their data dispersion for the measurement positions is relatively large. From these results, we can conclude that the hydrophilic and hydrophobic domains on the sapphire (0001) surfaces are distinguished by a difference in their hydration degrees.

  19. Magnetic and Crystalline Nanostructures in Ferrofluids as Probed by Small Angle Neutron Scattering

    Science.gov (United States)

    Wiedenmann, A.

    We present a newly developed technique of nuclear and magnetic contrast variation by using polarised neutrons in Small Angle Neutron Scattering (SANSPOL) which allows density, concentration and magnetisation fluctuations in magnetic liquids to be analysed simultaneously. Diluted Ferrofluids based on different magnetic materials (Co, Magnetite, Ba-ferrite) and stabilized by charges or surfactants in different carrier liquids have been investigated. In such polydisperse systems several constituents of similar sizes have been identified by this technique: Magnetic core-shell composites, magnetic aggregates and free surfactants. The corresponding size distributions, compositions and magnetic moments have been determined. In more concentrated Co-FF the nature of field induced particle arrangements has been determined.

  20. Probing spin helical surface states in topological HgTe nanowires

    Science.gov (United States)

    Ziegler, J.; Kozlovsky, R.; Gorini, C.; Liu, M.-H.; Weishäupl, S.; Maier, H.; Fischer, R.; Kozlov, D. A.; Kvon, Z. D.; Mikhailov, N.; Dvoretsky, S. A.; Richter, K.; Weiss, D.

    2018-01-01

    Nanowires with helical surface states represent key prerequisites for observing and exploiting phase-coherent topological conductance phenomena, such as spin-momentum locked quantum transport or topological superconductivity. We demonstrate in a joint experimental and theoretical study that gated nanowires fabricated from high-mobility strained HgTe, known as a bulk topological insulator, indeed preserve the topological nature of the surface states, that moreover extend phase-coherently across the entire wire geometry. The phase-coherence lengths are enhanced up to 5 μ m when tuning the wires into the bulk gap, so as to single out topological transport. The nanowires exhibit distinct conductance oscillations, both as a function of the flux due to an axial magnetic field and of a gate voltage. The observed h /e -periodic Aharonov-Bohm-type modulations indicate surface-mediated quasiballistic transport. Furthermore, an in-depth analysis of the scaling of the observed gate-dependent conductance oscillations reveals the topological nature of these surface states. To this end we combined numerical tight-binding calculations of the quantum magnetoconductance with simulations of the electrostatics, accounting for the gate-induced inhomogeneous charge carrier densities around the wires. We find that helical transport prevails even for strongly inhomogeneous gating and is governed by flux-sensitive high-angular momentum surface states that extend around the entire wire circumference.

  1. Spectropolarimetry of Giant stars: Probing the influence of magnetic field on evolved stars Spectropolarimetry of Giant stars: Probing the influence of magnetic field on evolved stars

    Science.gov (United States)

    da Costa, Jefferson; Castro, Matthieu; Petit, Pascal; do Nascimento, José-Dias, Jr.

    2015-08-01

    It is know that lithium is element easily destroyed in stellar interior, the existence of lithium rich stars means a great challenge in stellar evolution. In this context our observations ravels the serendipitous discovery of an unusually high lithium abundance star. This is a K0III HD 150050, which has strong deepening on lithium line (6707.8 Å) this means lithium abundance of 2.81 0.2 dex, therefore this star belong a rare group called super Li-Rich stars. A possible source of the non-standard episodes required to produce Li-rich stars were identified in magneto-thermohaline mixing accounted by models of extra-mixing induced by magnetic buoyancy. However to better understand this is necessary more observational data. In last three decades several studies has showed that late type red giant stars presents a remarkable modifications in these outer atmosphere layers when they become late type star in HR diagram. These changes are founded through X-ray, Ultraviolet, and Chromospheric activity analyses, and then we can establish the called “Dividing lines”. We made spectropalarimetric observations with ESPaDOnS@CFHT to achieve two main objectives: analyze the influence of magnetic field in the Li-rich giant stars, and understand how works the magnetic field in late type giants and supergiants across the “dividing line”.

  2. I-cored Coil Probe Located Above a Conductive Plate with a Surface Hole

    Directory of Open Access Journals (Sweden)

    Tytko Grzegorz

    2018-02-01

    Full Text Available This work presents an axially symmetric mathematical model of an I-cored coil placed over a two-layered conductive material with a cylindrical surface hole. The problem was divided into regions for which the magnetic vector potential of a filamentary coil was established applying the truncated region eigenfunction expansion method. Then the final formula was developed to calculate impedance changes for a cylindrical coil with reference to both the air and to a material with no hole. The influence of a surface flaw in the conductive material on the components of coil impedance was examined. Calculations were made in Matlab for a hole with various radii and the results thereof were verified with the finite element method in COMSOL Multiphysics package. Very good consistency was achieved in all cases.

  3. Modelling and experimental verification of tip-induced polarization in Kelvin probe force microscopy measurements on dielectric surfaces

    DEFF Research Database (Denmark)

    Nielsen, Dennis Achton; Popok, Vladimir; Pedersen, Kjeld

    2015-01-01

    Kelvin probe force microscopy is a widely used technique for measuring surface potential distributions on the micro- and nanometer scale. The data are, however, often analyzed qualitatively, especially for dielectrics. In many cases, the phenomenon of polarization and its influence on the measured...... signals is disregarded leading to misinterpretation of the results. In this work, we present a model that allows prediction of the surface potential on a metal/polymer heterostructure as measured by Kelvin probe force microscopy by including the tip-induced polarization of the dielectric that arises...

  4. Study on characteristics of eddy current array coil operated in transmit-receive mode and surface inspection using this probe

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Tae Hun; Jee, Dong Hyun; Cho, Chan Hee; Kim, In Chul [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2017-02-15

    Eddy current array (ECA) technology provides the ability to electronically scan without mechanical scanning for a footprint of probe that consists of several eddy current coils arranged side-by-side and two dimensionally. Compared to single-coil eddy current technology, the ECA technology has a higher inspection speed and reliability because a large area can be covered in a single-probe pass and the obtained images can facilitate data interpretation. In this study, we developed an eddy current array probe with 2×16 coil arrays and a multiplexer that can select transmit-receive coils sequentially and operate in transmit-receive mode. Surface inspection was performed using this probe for specimens that had various flaws and the characteristics of transmit-receive mode ECA technology was studied through an analysis of the obtained eddy current signals and C-scan images.

  5. Hyperfine fields in a Ag/Fe magnetic multilayer probed with low energy spin polarized {sup 8}Li

    Energy Technology Data Exchange (ETDEWEB)

    Keeler, T.A. [Department of Physics and Astronomy, University of British Columbia, Vancouver, BC, V6T 1Z1 (Canada); Salman, Z. [TRIUMF, 4004 Wesbrook Mall, Vancouver, V6T 2A3 (Canada); Chow, K.H. [Department of Physics, University of Alberta, Edmonton, AB, T6G 2J1 (Canada); Heinrich, B. [Department of Physics, Simon Fraser University, Vancouver, BC (Canada); Hossain, M.D. [Department of Physics and Astronomy, University of British Columbia, Vancouver, BC, V6T 1Z1 (Canada); Kardasz, B. [Department of Physics, Simon Fraser University, Vancouver, BC (Canada); Kiefl, R.F. [Department of Physics and Astronomy, University of British Columbia, Vancouver, BC, V6T 1Z1 (Canada)]. E-mail: kiefl@triumf.ca; Kreitzman, S.R. [TRIUMF, 4004 Wesbrook Mall, Vancouver, V6T 2A3 (Canada); MacFarlane, W.A. [Department of Chemistry, University of British Columbia, Vancouver, V6T 1Z1 (Canada); Mosendz, O. [Department of Physics, Simon Fraser University, Vancouver, BC (Canada); Parolin, T.J. [Department of Chemistry, University of British Columbia, Vancouver, V6T 1Z1 (Canada); Wang, D. [Department of Physics and Astronomy, University of British Columbia, Vancouver, BC, V6T 1Z1 (Canada)

    2006-03-31

    A beam of low energy Li8 has been used to probe the hyperfine field distribution in a magnetic multilayer composed of Au(4nm)/Ag(80nm)/Fe(2nm) grown on a GaAs substrate. The {beta}-NMR frequency spectrum is shown to be a strong function of the implantation energy reflecting the depth dependence of the local hyperfine fields. Correlating the spectra with TRIM.SP implantation profiles allows us to identify signals from the GaAs, Ag and Au layers. The frequency spectrum in Ag is a strong function of energy. A very narrow line, and corresponding distribution of hyperfine fields, is observed when the beam in centered well away from the Fe whereas a much broader distribution is observed when the Li stops close to the Fe. These results demonstrate that low energy {beta}-NMR can act as a sensitive probe of the induced magnetism in the otherwise non-magnetic Ag spacer layers.

  6. Identification of waves by RF magnetic probes during lower hybrid wave injection experiments on the TST-2 spherical tokamak

    International Nuclear Information System (INIS)

    Shinya, Takahiro; Ejiri, Akira; Takase, Yuichi

    2014-01-01

    RF magnetic probes can be used to measure not only the wavevector, but also the polarization of waves in plasmas. A 5-channel RF magnetic probe (5ch-RFMP) was installed in the TST-2 spherical tokamak and the waves were studied in detail during lower hybrid wave injection experiments. From the polarization measurements, the poloidal RF magnetic field is found to be dominant. In addition to polarization, components of k perpendicular to the major radial direction were obtained from phase differences among the five channels. The radial wavenumber was obtained by scanning the radial position of the 5ch-RFMP on a shot by shot basis. The measured wavevector and polarization in the plasma edge region were consistent with those calculated from the wave equation for the slow wave branch. While the waves with small and large k ∥ were excited by the antenna, only the small k ∥ component was measured by the 5ch-RFMP; this suggests that the waves with larger k ∥ were absorbed by the plasma. (author)

  7. Technology of magnetic abrasive finishing in machining of difficult-to-machine alloy complex surface

    Directory of Open Access Journals (Sweden)

    Fujian MA

    2016-10-01

    Full Text Available The technology of magnetic abrasive finishing is one of the important finishing technologies. Combining with low-frequency vibration and ultrasonic vibration, it can attain higher precision, quality and efficiency. The characteristics and the related current research of magnetic abrasive finishing, vibration assisted magnetic abrasive finishing and ultrasonic assisted magnetic abrasive finishing are introduced. According to the characteristics of the difficult-to-machine alloy's complex surface, the important problems for further study are presented to realize the finishing of complex surface with the technology of magnetic abrasive finishing, such as increasing the machining efficiency by enhancing the magnetic flux density of machining gap and compounding of magnetic energy and others, establishing of the control function during machining and the process planning method for magnetic abrasive finishing of complex surface under the space geometry restraint of complex surface on magnetic pole, etc.

  8. Spectroscopic, imaging, and probe diagnostics of laser plasma plumes expanding between confining surfaces

    International Nuclear Information System (INIS)

    Yeates, P.; Kennedy, E. T.

    2010-01-01

    Laser plasma plumes were generated in aluminum rectangular cavities of fixed depth (6 mm) and varying height (2.0, 1.5, and 1.0 mm). Space and time resolved visible emission spectroscopy, gated intensified visible imaging, and Langmuir probe diagnostics were utilized to diagnose the evolution of the confined plasma plumes in comparison to freely expanding plasma plume generated from ablation of a planar target. The constrained plasma behavior displayed a multiphase history. Early stage interactions (t 160 ns) resulted in sustained 'decay', i.e., a rapid termination of continuum emission, in concert with decreases in peak electron density (N e ) and plasma temperature (T). This later phase originates from loss mechanisms which bleed the plasma plume of thermal energy and charged particles. These loss mechanisms increase in magnitude as the duration of the plasma-surface interaction increases. The transition from enhancement phase, originating from hydrodynamic containment, and plasma-surface collisions, to decay phase is described and occurs for each cavity at a different point in the space time history.

  9. Lavoisier: A Low Altitude Balloon Network for Probing the Deep Atmosphere and Surface of Venus

    Science.gov (United States)

    Chaasefiere, E.; Berthelier, J. J.; Bertaux, J.-L.; Quemerais, E.; Pommereau, J.-P.; Rannou, P.; Raulin, F.; Coll, P.; Coscia, D.; Jambon, A.; hide

    2005-01-01

    The in-situ exploration of the low atmosphere and surface of Venus is clearly the next step of Venus exploration. Understanding the geochemistry of the low atmosphere, interacting with rocks, and the way the integrated Venus system evolved, under the combined effects of inner planet cooling and intense atmospheric greenhouse, is a major challenge of modern planetology. Due to the dense atmosphere (95 bars at the surface), balloon platforms offer an interesting means to transport and land in-situ measurement instruments. Due to the large Archimede force, a 2 cubic meter He-pressurized balloon floating at 10 km altitude may carry up to 60 kg of payload. LAVOISIER is a project submitted to ESA in 2000, in the follow up and spirit of the balloon deployed at cloud level by the Russian Vega mission in 1986. It is composed of a descent probe, for detailed noble gas and atmosphere composition analysis, and of a network of 3 balloons for geochemical and geophysical investigations at local, regional and global scales.

  10. Estimation of cerebral surface area using vertical sectioning and magnetic resonance imaging: a stereological study.

    Science.gov (United States)

    Acer, Niyazi; Cankaya, Mehmet Niyazi; Işçi, Oznur; Baş, Orhan; Camurdanoğlu, Mehmet; Turgut, Mehmet

    2010-01-15

    Stereological techniques using isotropic uniform random and vertical uniform random sections have been used for surface area estimation. However, there are a few studies in which the surface area of the brain is estimated using the vertical section technique in a stereological approach. The objective of the current study was to apply the vertical section technique using cycloid test probes for estimation of cerebral surface area in magnetic resonance imaging (MRI). In this study, cerebral surface areas were estimated in a total of 13 young subjects (6 males, 7 females) who were free of any neurological symptoms and signs. The means (+/-S.D.) of the surface areas were 1619.92+/-140. 97 cm (2), 1625.69+/-147. 58 cm(2) and 1674.69+/-160. 60 cm(2) for 36, 18 and 12 vertical sections, respectively. The mean coefficient of error obtained by applying cycloid test lines that use a 2. 8-cm ratio of area associated with each cycloid was estimated at 0.05). In addition, the three models correlated well with each other. From these results, it is concluded that the vertical section technique is an unbiased, efficient and reliable method and is ideally suited to in vivo examination of MRI data for estimating the surface area of the brain. Hence, we suggest that estimation of surface area using MRI and stereology may be clinically relevant for assessing cortical atrophy as well as for investigating the structure and function of cerebral hemispheres. Copyright 2009 Elsevier B.V. All rights reserved.

  11. Surface enhanced Raman spectroscopic studies on magnetic Fe3O4@AuAg alloy core-shell nanoparticles

    Science.gov (United States)

    Sun, Hai-Long; Xu, Min-Min; Guo, Qing-Hua; Yuan, Ya-Xian; Shen, Li-Ming; Gu, Ren-Ao; Yao, Jian-Lin

    2013-10-01

    A facile approach has been developed to fabricate multifunctional Fe3O4@AuAg alloy core-shell nanoparticles, owning the magnetism of the core and the surface enhanced Raman spectroscopy (SERS) activities of the alloy shell. By changing the amount of HAuCl4 and AgNO3, Fe3O4@AuAg alloy nanoparticles with different component ratios of Au and Ag were successfully prepared. The surface plasmon resonance of the composition was linearly tuned in a wide range by varying the molar fraction of Ag and Au, suggesting the formation of AuAg alloy shell. SERS and magnetic enrichment effects were investigated by using thiophenol (TP) as the probe molecule. The SERS intensity was strongly dependent on the molar ratios of Au and Ag and the excitation line. Enrichment for the molecules with low concentration and on line SERS monitoring experiments were performed through combining the magnetism of the core and the SERS effect of the alloy shell. The results revealed that the magnetic enrichment efficiency was dramatically increased due to the strong magnetism of Fe3O4 core. In addition, the Fe3O4@AuAg nanoparticles were also used in the microfluidic chip to continuously detect different flowing solution in the channel. The detection time and amount of analyte were successfully decreased.

  12. Eddy current probe development based on a magnetic sensor array; Developpement d'un imageur magnetique pour le controle non destructif par courants de Foucault

    Energy Technology Data Exchange (ETDEWEB)

    Vacher, F

    2007-06-15

    This research deals with in the study of the use of innovating magnetic sensors in eddy current non destructive inspection. The author reports an analysis survey of magnetic sensor performances. This survey enables the selection of magnetic sensor technologies used in non destructive inspection. He presents the state-of-the-art of eddy current probes exploiting the qualities of innovating magnetic sensors, and describes the methods enabling the use of these magnetic sensors in non destructive testing. Two main applications of innovating magnetic sensors are identified: the detection of very small defects by means of magneto-resistive sensors, and the detection of deep defects by means of giant magneto-impedances. Based on the use of modelling, optimization, signal processing tools, probes are manufactured for these both applications.

  13. Control of magnetism in dilute magnetic semiconductor (Ga,MnAs films by surface decoration of molecules

    Directory of Open Access Journals (Sweden)

    Hailong eWang

    2016-03-01

    Full Text Available The responses of magnetic moments to external stimuli such as magnetic-field, heat, light and electric-field have been utilized to manipulate the magnetism in magnetic semiconductors, with many of the novel ideas applied even to ferromagnetic metals. Here, we review a new experimental development on the control of magnetism in (Ga,MnAs thin films by surface decoration of organic molecules: Molecules deposited on the surface of (Ga,MnAs thin films are shown to be capable of significantly modulating their saturation magnetization and Curie temperature. These phenomena are shown to originate from the carrier-mediated ferromagnetism in (Ga,MnAs and the surface molecules acting as acceptors or donors depending on their highest occupied molecular orbitals, resembling the charge transfer mechanism in a pn junction in which the equilibrium state is reached on the alignment of Fermi levels.

  14. Revisiting magnetism of capped Au and ZnO nanoparticles: Surface band structure and atomic orbital with giant magnetic moment

    Energy Technology Data Exchange (ETDEWEB)

    Hernando, Antonio; Crespo, Patricia [Instituto de Magnetismo Aplicado, UCM-CSIC-ADIF, Las Rozas. P.O. Box 155, 28230 Madrid (Spain); Dept. Fisica de Materiales, Universidad Complutense, Madrid (Spain); Garcia, Miguel Angel [Instituto de Ceramica y Vidrio, CSIC, C/ Kelsen, 5, Madrid 28049 (Spain); Coey, Michael [Trinity College Dublin, Dublin (Ireland); Ayuela, Andres; Echenique, Pedro Miguel [Centro de Fisica de Materiales, CFM-MPC CSIC-UPV/EHU, Donostia International Physics Center (DIPC), 20018 San Sebastian (Spain); Departamento de Fisica de Materiales, Fac. de Quimicas, Universidad del Pais Vasco UPV-EHU, 20018 San Sebastian (Spain)

    2011-10-15

    In this article we review the exotic magnetism of nanoparticles (NPs) formed by substances that are not magnetic in bulk as described with generality in Section 1. In particular, the intrinsic character of the magnetism observed on capped Au and ZnO NPs is analysed. X-ray magnetic circular dichroism (XMCD) analysis has shown that the magnetic moments are intrinsic and lie in the Au and Zn atoms, respectively, as analysed in Section 2, where the general theoretical ideas are also revisited. Since impurity atoms bonded to the surface act as donor or acceptor of electrons that occupy the surface states, the anomalous magnetic response is analysed in terms of the surface band in Section 3. Finally, Section 4 summarizes our last theoretical proposal. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  15. Comparative measurements of plasma potential with ball-pen and Langmuir probe in low-temperature magnetized plasma

    Czech Academy of Sciences Publication Activity Database

    Zanáška, M.; Adámek, Jiří; Peterka, Matěj; Kudrna, P.; Tichý, M.

    2015-01-01

    Roč. 22, č. 3 (2015), č. článku 033516. ISSN 1070-664X Institutional support: RVO:61389021 Keywords : plasma * tokamak * ball- pen probe (BPP) Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: Fluids and plasma physics (including surface physics) Impact factor: 2.207, year: 2015 http://scitation.aip.org/content/aip/journal/pop/22/3/10.1063/1.4916572

  16. Probing potential energy surfaces with high-resolution spectroscopy : From the Universe's carbon locker to molecular machines

    NARCIS (Netherlands)

    Maltseva, E.O.

    2017-01-01

    Light is a powerful tool that, on the one hand, can alter the molecular state and, on the other hand, can be used to probe molecular properties without changing the state. Fundamentals of these interactions are potential energy surfaces (PESs) of molecular ground and electronically excited states.

  17. Two dimensional electron gas confined over a spherical surface: Magnetic moment

    Energy Technology Data Exchange (ETDEWEB)

    Hernando, A; Crespo, P [Instituto de Magnetismo Aplicado, UCM-CSIC-ADIF, Las Rozas. P. O. Box 155, Madrid 28230 (Spain) and Dpto. Fisica de Materiales, Universidad Complutense (Spain); Garcia, M A, E-mail: antonio.hernando@adif.es [Instituto de Ceramica y Vidrio, CSIC c/Kelsen, 5 Madrid 28049 (Spain)

    2011-04-01

    Magnetism of capped nanoparticles, NPs, of non-magnetic substances as Au and ZnO is briefly reviewed. The source of the magnetization is discussed on the light of recent X-ray magnetic circular dichroism experiments. As magnetic dichroism analysis has pointed out impurity atoms bonded to the surface act as donor or acceptor of electrons that occupy the surface states. It is proposed that mesoscopic collective orbital magnetic moments induced at the surface states can account for the experimental magnetism characteristic of these nanoparticles. The total magnetic moment of the surface originated at the unfilled Fermi level can reach values as large as 10{sup 2} or 10{sup 3} Bohr magnetons.

  18. A new temperature profiling probe for investigating groundwater-surface water interaction

    Science.gov (United States)

    Naranjo, Ramon C.; Robert Turcotte,

    2015-01-01

    Measuring vertically nested temperatures at the streambed interface poses practical challenges that are addressed here with a new discrete subsurface temperature profiling probe. We describe a new temperature probe and its application for heat as a tracer investigations to demonstrate the probe's utility. Accuracy and response time of temperature measurements made at 6 discrete depths in the probe were analyzed in the laboratory using temperature bath experiments. We find the temperature probe to be an accurate and robust instrument that allows for easily installation and long-term monitoring in highly variable environments. Because the probe is inexpensive and versatile, it is useful for many environmental applications that require temperature data collection for periods of several months in environments that are difficult to access or require minimal disturbance.

  19. Advanced Magnetic Resonance Imaging techniques to probe muscle structure and function

    Science.gov (United States)

    Malis, Vadim

    Structural and functional Magnetic Resonance Imaging (MRI) studies of skeletal muscle allow the elucidation of muscle physiology under normal and pathological conditions. Continuing on the efforts of the Muscle Imaging and Modeling laboratory, the focus of the thesis is to (i) extend and refine two challenging imaging modalities: structural imaging using Diffusion Tensor Imaging (DTI) and functional imaging based on Velocity Encoded Phase Contrast Imaging (VE-PC) and (ii) apply these methods to explore age related structure and functional differences of the gastrocnemius muscle. Diffusion Tensor Imaging allows the study of tissue microstructure as well as muscle fiber architecture. The images, based on an ultrafast single shot Echo Planar Imaging (EPI) sequence, suffer from geometric distortions and low signal to noise ratio. A processing pipeline was developed to correct for distortions and to improve image Signal to Noise Ratio (SNR). DTI acquired on a senior and young cohort of subjects were processed through the pipeline and differences in DTI derived indices and fiber architecture between the two cohorts were explored. The DTI indices indicated that at the microstructural level, fiber atrophy was accompanied with a reduction in fiber volume fraction. At the fiber architecture level, fiber length and pennation angles decreased with age that potentially contribute to the loss of muscle force with age. Velocity Encoded Phase Contrast imaging provides tissue (e.g. muscle) velocity at each voxel which allows the study of strain and Strain Rate (SR) under dynamic conditions. The focus of the thesis was to extract 2D strain rate tensor maps from the velocity images and apply the method to study age related differences. The tensor mapping can potentially provide unique information on the extracellular matrix and lateral transmission the role of these two elements has recently emerged as important determinants of force loss with age. In the cross sectional study on

  20. Direct Surface and Droplet Microsampling for Electrospray Ionization Mass Spectrometry Analysis with an Integrated Dual-Probe Microfluidic Chip

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Cong-Min [Institute of Microanalytical; Zhu, Ying [Institute of Microanalytical; Jin, Di-Qiong [Institute of Microanalytical; Kelly, Ryan T. [Environmental; Fang, Qun [Institute of Microanalytical

    2017-08-15

    Ambient mass spectrometry (MS) has revolutionized the way of MS analysis and broadened its application in various fields. This paper describes the use of microfluidic techniques to simplify the setup and improve the functions of ambient MS by integrating the sampling probe, electrospray emitter probe, and online mixer on a single glass microchip. Two types of sampling probes, including a parallel-channel probe and a U-shaped channel probe, were designed for dryspot and liquid-phase droplet samples, respectively. We demonstrated that the microfabrication techniques not only enhanced the capability of ambient MS methods in analysis of dry-spot samples on various surfaces, but also enabled new applications in the analysis of nanoliter-scale chemical reactions in an array of droplets. The versatility of the microchip-based ambient MS method was demonstrated in multiple different applications including evaluation of residual pesticide on fruit surfaces, sensitive analysis of low-ionizable analytes using postsampling derivatization, and high-throughput screening of Ugi-type multicomponent reactions.

  1. Probing magnetic bottom and crustal temperature variations along the Red Sea margin of Egypt

    Science.gov (United States)

    Ravat, D.; Salem, A.; Abdelaziz, A.M.S.; Elawadi, E.; Morgan, P.

    2011-01-01

    Over 50 magnetic bottom depths derived from spectra of magnetic anomalies in Eastern Egypt along the Red Sea margin show variable magnetic bottoms ranging from 10 to 34. km. The deep magnetic bottoms correspond more closely to the Moho depth in the region, and not the depth of 580??C, which lies significantly deeper on the steady state geotherms. These results support the idea of Wasilewski and coworkers that the Moho is a magnetic boundary in continental regions. Reduced-to-pole magnetic highs correspond to areas of Younger Granites that were emplaced toward the end of the Precambrian. Other crystalline Precambrian units formed earlier during the closure of ocean basins are not strongly magnetic. In the north, magnetic bottoms are shallow (10-15. km) in regions with a high proportion of these Younger Granites. In the south, the shoaling of the magnetic bottom associated with the Younger Granites appears to be restricted to the Aswan and Ras Banas regions. Complexity in the variation of magnetic bottom depths may arise due to a combination of factors: i) regions of Younger (Precambrian) Granites with high magnetite content in the upper crust, leaving behind low Curie temperature titanomagnetite components in the middle and lower crust, ii) rise in the depth of 580??C isotherm where the crust may have been heated due to initiation of intense magmatism at the time of the Red Sea rifting (~. 20. Ma), and iii) the contrast of the above two factors with respect to the neighboring regions where the Moho and/or Curie temperature truncates lithospheric ferromagnetism. Estimates of fractal and centroid magnetic bottoms in the oceanic regions of the Red Sea are significantly below the Moho in places suggesting that oceanic uppermost mantle may be serpentinized to the depth of 15-30 km in those regions. ?? 2011 Elsevier B.V.

  2. Surface flute modes in the bumpy magnetic field

    International Nuclear Information System (INIS)

    Girka, I.O.; Girka, V.O.; Lapshin, V.I.

    2005-01-01

    Surface electromagnetic waves are often determined as the most possible cause of undesirable heating of edge plasma that leads, in turn, to strengthening of plasma - wall interaction in stellarators and increased plasma contamination. The propagation of surface flute modes near the interface of plasma column separated by a vacuum layer from the ring cylindrical ideally conductive metallic chamber is studied. The external steady bumpy magnetic field B-vector 0 = B 0z e-vector z + B 0r e-vector r was considered, B 0z =B 00 [1+ε m (r)cos(k m z)], here ε m '≡dε m /dr, k m =2π/L, L is the period of nonuniformity. non-uniformity of B-vector 0 is planned to be dominant in the confining magnetic field of the modular stellarator Helias, ε m ∼ 0.13. In the bumpy magnetic field the electromagnetic disturbance propagates in the form of the wave envelope, in which one alongside with the fundamental harmonic, proportional to exp[i(mθ±-ωt)], infinite set of satellite spatial harmonics, proportional to exp[i(mθ ± jk m z - ωt)], j=1,2,3..., is present. It is shown, that in the first approximation in the respect to ε m , amplitudes of the fundamental harmonics of the E-wave with the field components E r , E θ , B z do not vary, small satellite harmonics of these fields arise, proportional to exp[i(mθ ± k m z - ωt)]. At the same time due to weak coupling of - and - modes, caused by B-vector 0 nonuniformity and nonzero axial wave number of satellite harmonics, small satellite harmonics of H-wave with the field components E z , B r , B θ also arise. The amplitudes of satellite harmonics of E-wave are shown to be symmetric: E r (+) =E r (-) , E θ (+) =E θ (-) , B z (+) =B z (-) , and the amplitudes of H-wave are antisymmetric: B r (+) =-B r (-) , B θ (+) =- B θ (-) , E z (+) =-E z (-) . In the second approximation in the respect to ε m corrections to the amplitudes of the fundamental harmonic of E-wave arise. The correction to the eigen frequency of the wave

  3. Streams and magnetic fields in surface layers of Ap-stars

    International Nuclear Information System (INIS)

    Dolginov, A.Z.; Urpin, V.A.

    1978-01-01

    Magnetic field generation of Ap-stars is considered. It is shown that in the surface layers of Ap-stars inhomogeneity of chemical composition produces a strong magnetic field. Velocities of possible circulation of stellar matter are estimated. It is shown that circulation does not prevent the process of the magnetic field generation. It needs the order of million years, for arranging the stationary magnetic field in surface layers

  4. Design and construction of small magnetic probes for a toroidal plasma machine

    International Nuclear Information System (INIS)

    McLeod, R.

    1975-01-01

    A number of probes were built with consideration given to the problems of heating, caused by bombardment by the hot plasma, interaction of the probe on the plasma, stray pick up by inaccurate alignment and accidental damage to the delicate coils. These problems were resolved by the following design criteria: 1. Heat resistant materials and thermocouple attached. 2. Dimensions kept to a minimum size. 3. Double layer coils wound back on themselfes and lead tightly twisted together. 4. Coils accurately aligned. 5. Protective covering over coils. (author)

  5. Spin-polarized scanning tunneling microscopy with quantitative insights into magnetic probes.

    Science.gov (United States)

    Phark, Soo-Hyon; Sander, Dirk

    2017-01-01

    Spin-polarized scanning tunneling microscopy and spectroscopy (spin-STM/S) have been successfully applied to magnetic characterizations of individual nanostructures. Spin-STM/S is often performed in magnetic fields of up to some Tesla, which may strongly influence the tip state. In spite of the pivotal role of the tip in spin-STM/S, the contribution of the tip to the differential conductance d I /d V signal in an external field has rarely been investigated in detail. In this review, an advanced analysis of spin-STM/S data measured on magnetic nanoislands, which relies on a quantitative magnetic characterization of tips, is discussed. Taking advantage of the uniaxial out-of-plane magnetic anisotropy of Co bilayer nanoisland on Cu(111), in-field spin-STM on this system has enabled a quantitative determination, and thereby, a categorization of the magnetic states of the tips. The resulting in-depth and conclusive analysis of magnetic characterization of the tip opens new venues for a clear-cut sub-nanometer scale spin ordering and spin-dependent electronic structure of the non-collinear magnetic state in bilayer high Fe nanoislands on Cu(111).

  6. Orbital Effects of In-Plane Magnetic Fields Probed by Mesoscopic Conductance Fluctuations

    DEFF Research Database (Denmark)

    Zumbuhl, D.; Miller, Jessica; M. Marcus, C.

    2003-01-01

    We use the high sensitivity to magnetic flux of mesoscopic conductance fluctuations in large quantum dots to investigate changes in the two-dimensional electron dispersion caused by an in-plane magnetic field. In particular, changes in effective mass and the breaking of momentum reversal symmetry...

  7. The magnetic particle in a box: Analytic and micromagnetic analysis of probe-localized spin wave modes

    Science.gov (United States)

    Adur, Rohan; Du, Chunhui; Manuilov, Sergei A.; Wang, Hailong; Yang, Fengyuan; Pelekhov, Denis V.; Hammel, P. Chris

    2015-05-01

    The dipole field from a probe magnet can be used to localize a discrete spectrum of standing spin wave modes in a continuous ferromagnetic thin film without lithographic modification to the film. Obtaining the resonance field for a localized mode is not trivial due to the effect of the confined and inhomogeneous magnetization precession. We compare the results of micromagnetic and analytic methods to find the resonance field of localized modes in a ferromagnetic thin film, and investigate the accuracy of these methods by comparing with a numerical minimization technique that assumes Bessel function modes with pinned boundary conditions. We find that the micromagnetic technique, while computationally more intensive, reveals that the true magnetization profiles of localized modes are similar to Bessel functions with gradually decaying dynamic magnetization at the mode edges. We also find that an analytic solution, which is simple to implement and computationally much faster than other methods, accurately describes the resonance field of localized modes when exchange fields are negligible, and demonstrating the accessibility of localized mode analysis.

  8. Research on the best measurement situation between optical probe and tissue surfaces in non-invasive detection

    Science.gov (United States)

    Yu, Xuyao; Liu, Rong; Yu, Hui; Wang, Jiao; Wang, Jun; Xu, Kexin

    2016-11-01

    Near-infrared spectroscopy is often used for the non-invasive detection of composition in the human body, such as that of blood glucose and haemoglobin, due to its high penetration depth into tissues. Although it is feasible to position the optical probe precisely, contact situation between probe and human tissues is a difficult problem to determine because of physiological tremor and mechanical performance of bio-soft tissue. Here, we proposed a novel estimation method for the situation between the optical probe and tissue surfaces based on the dynamic auto-correlation matrix of two-dimensional correlation spectroscopy (2DCOS) and radar chart. The diffuse reflectance spectra from the left palm of 4 healthy volunteers were collected while the optical probe gradually approached and pressed bio-tissues with a custom-design controlling device. 2DCOS in the wavelength with lower absorption (1000-1400 nm) was calculated under the perturbation of relative-distance and contact pressure between the optical probe and tissue surface. The synchronous 2DCOS showed that the surface reflection and diffuse reflectance were greatly affected by the contact conditions in 1100 nm, 1220 nm, and 1300 nm. Then the dynamic auto-correlation matrix of 2DCOS was established for the adjacent spectra, and the significant difference wavelengths were used to build radar charts to determine the critical contact situation visually. Results showed that the maximum variations of dynamic auto-correlation matrix appeared at near 1300 nm, and the relative distance between the probe and tissue corresponding to the critical contact state can be easily observed with radar charts with 0.25 mm uncertainty, which was consistent with the self-feeling of each volunteer. So this method can be applied to exactly determine the optimal measurement status for the non-invasive body composition detection in vivo. It is important for the design of human-machine interface and the accuracy improvement of body

  9. Method of driving liquid flow at or near the free surface using magnetic microparticles

    Science.gov (United States)

    Snezhko, Oleksiy [Woodridge, IL; Aronson, Igor [Darien, IL; Kwok, Wai-Kwong [Evanston, IL; Belkin, Maxim V [Woodridge, IL

    2011-10-11

    The present invention provides a method of driving liquid flow at or near a free surface using self-assembled structures composed of magnetic particles subjected to an external AC magnetic field. A plurality of magnetic particles are supported at or near a free surface of liquid by surface tension or buoyancy force. An AC magnetic field traverses the free surface and dipole-dipole interaction between particles produces in self-assembled snake structures which oscillate at the frequency of the traverse AC magnetic field. The snake structures independently move across the free surface and may merge with other snake structures or break up and coalesce into additional snake structures experiencing independent movement across the liquid surface. During this process, the snake structures produce asymmetric flow vortices across substantially the entirety of the free surface, effectuating liquid flow across the free surface.

  10. New insight in the nature of surface magnetic anisotropy in iron borate

    Science.gov (United States)

    Strugatsky, M.; Seleznyova, K.; Zubov, V.; Kliava, J.

    2018-02-01

    The theory of surface magnetism of iron borate, FeBO3, has been extended by taking into consideration a crystal field contribution to the surface magnetic anisotropy energy. For this purpose, a model of distortion of the six-fold oxygen environment of iron ions in the near-surface layer of iron borate has been put forward. The spin Hamiltonian parameters for isolated Fe3+ ions in the distorted environment of the near-surface layer have been calculated using the Newman's superposition model. The crystal field contribution to the surface magnetic anisotropy energy has been calculated in the framework of the perturbation theory. The model developed allows concluding that the distortions of the iron environment produce a significant crystal field contribution to the surface magnetic anisotropy constant. The results of experimental studies of the surface magnetic anisotropy in iron borate can be described assuming the existence of relative contractions in the near-surface layer of the order of 1 %.

  11. Hotspot detection and spatial distribution of methane emissions from landfills by a surface probe method.

    Science.gov (United States)

    Gonzalez-Valencia, Rodrigo; Magana-Rodriguez, Felipe; Cristóbal, Jordi; Thalasso, Frederic

    2016-09-01

    A surface probe method previously developed was used to detect hotspots and to determine spatial variation of methane (CH4) emissions from three landfills located in Mexico, with an intermediate or a final cover, as well as with or without a landfill gas collection system. The method was effective in the three landfills and allowed mapping of CH4 emissions with a resolution of 24-64 measurements per hectare, as well as the detection and quantification of hotspots, with a moderate experimental effort. In the three selected landfills, CH4 emissions were quantified to 10, 72, and 575gm(-2)d(-1). Two straightforward parameters describing the spatial distribution of CH4 emissions were also developed. The first parameter provides the percentage of area responsible for a given percentage of total emissions, while the second parameter assigns a numerical value to flux homogeneity. Together, the emissions map and the spatial distribution parameters offer an appropriate tool to landfill operators willing to begin recovering CH4 emissions or to improve the effectiveness of an existing recovery system. This method may therefore help to reduce the greenhouse gas footprint of landfills, which are still the primary option for waste management in developing countries. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Direct protein quantification in complex sample solutions by surface-engineered nanorod probes

    KAUST Repository

    Schrittwieser, Stefan

    2017-06-30

    Detecting biomarkers from complex sample solutions is the key objective of molecular diagnostics. Being able to do so in a simple approach that does not require laborious sample preparation, sophisticated equipment and trained staff is vital for point-of-care applications. Here, we report on the specific detection of the breast cancer biomarker sHER2 directly from serum and saliva samples by a nanorod-based homogeneous biosensing approach, which is easy to operate as it only requires mixing of the samples with the nanorod probes. By careful nanorod surface engineering and homogeneous assay design, we demonstrate that the formation of a protein corona around the nanoparticles does not limit the applicability of our detection method, but on the contrary enables us to conduct in-situ reference measurements, thus further strengthening the point-of-care applicability of our method. Making use of sandwich assays on top of the nanorods, we obtain a limit of detection of 110 pM and 470 pM in 10-fold diluted spiked saliva and serum samples, respectively. In conclusion, our results open up numerous applications in direct protein biomarker quantification, specifically in point-of-care settings where resources are limited and ease-of-use is of essence.

  13. Variation of Radiation Belt Content Indices and total electron energy During Magnetic Storms Based On Van Allen Probe Observations

    Science.gov (United States)

    Xiong, Y.; Xie, L.; Chen, L.; Pu, Z.

    2017-12-01

    We investigate the variability of the RBC indices and total electron energy for varying energies within outer belt during 42 isolate magnetic storms based on the electron flux data from MagEIS and REPT onboard Van Allen Probe-A spacecraft. Van Allan Probes travel throughout the entire radiation belt twice during each orbit, providing an excellent opportunity to measure the electron's pitch angle distributions near the magnetic equatorial plane which is essential to calculate the RBC index accurately. Instead of assuming an isotropic electron pitch angle distribution which is widely used in previous studies, we develop a new and reliable technique to infer the equatorial pitch angle distributions based on the off-equator measurements. The statistic results show that the total electron energy in outer belt increase in 80% storms and has a positive correlation with median value of AE during recovery phase and minimum -Dst. The possibility of observing RBC depletion increase at high energies. The upper limit energy of RBC enhancement has a positive correlation with median value of AE and Vsw during recovery phase and a negative correlation with median value of Nsw during storm, which is consist of the balance of acceleration by chorus waves and loss by EMIC waves.

  14. Results from the magnetic electron ion spectrometer (MagEIS) instruments aboard the Van Allen Probes spacecraft

    Science.gov (United States)

    Fennell, Joseph; O'Brien, Paul; Roeder, James; Reeves, Geoffrey; Claudepierre, Seth; Clemmons, James; Spence, Harlan; Blake, Bernard

    The Magnetic Electron Ion Spectrometer (MagEIS) instruments aboard the Van Allen Probes Spacecraft (formerly RBSP) measure electrons and ions in the Earth's inner and outer radiation belts. The MagEIS instruments are part of the Energetic Particle, Composition, and Thermal Plasma Suite (ECT), which also includes the Relativistic Electron Proton Telescope (REPT) and the Helium Oxygen Proton Electron (HOPE) analyzer. MagEIS consists of four magnetic electron spectrometers aboard each of the two Van Allen Probes spacecraft that measure the differential fluxes, energies, and angular distributions of electrons from 20 keV to 4 MeV. The MagEIS suite also contains a silicon-detector telescope that measures the differential fluxes, energies, and angular distributions of protons from 60 keV to 20 MeV, and helium and oxygen ions above a hundred keV/AMU. We briefly describe the instrument design and measurement technique and present a set of results from the MagEIS observations, including ultra-low frequency (ULF) modulations of energetic electron flux, and observations of electron flux enhancements associated with the recent BARREL x-ray observations.

  15. Initial Results from the Magnetic Electron Ion Spectrometer (MagEIS) Instruments Aboard the Van Allen Probes Spacecraft

    Science.gov (United States)

    Claudepierre, S. G.; Blake, J. B.; Fennell, J. F.; Clemmons, J. H.; Roeder, J. L.; Spence, H. E.; Reeves, G. D.; Van Allen Probes ECT Team

    2013-05-01

    The Magnetic Electron Ion Spectrometer (MagEIS) instruments aboard the Van Allen Probes Spacecraft (formerly RBSP) measure electrons and ions in the Earth's inner and outer radiation belts. The MagEIS instruments are part of the Energetic Particle, Composition, and Thermal Plasma Suite (ECT), which also includes the Relativistic Electron Proton Telescope (REPT) and the Helium Oxygen Proton Electron (HOPE) analyzer. MagEIS consists of four magnetic electron spectrometers aboard each of the two Van Allen Probes spacecraft that measure the differential fluxes, energies, and angular distributions of electrons from 20 keV to 4 MeV. The MagEIS suite also contains a silicon-detector telescope that measures the differential fluxes, energies, and angular distributions of protons from 60 keV to 20 MeV, and helium and oxygen ions above a hundred keV/AMU. We briefly describe the instrument design and measurement technique and present a set of initial results from the MagEIS observations, including ultra-low frequency (ULF) modulations of energetic electron flux, and observations of electron flux enhancements associated with the recent BARREL x-ray observations.

  16. Fabrication of nano-sized magnetic tunnel junctions using lift-off process assisted by atomic force probe tip.

    Science.gov (United States)

    Jung, Ku Youl; Min, Byoung-Chul; Ahn, Chiyui; Choi, Gyung-Min; Shin, Il-Jae; Park, Seung-Young; Rhie, Kungwon; Shin, Kyung-Ho

    2013-09-01

    We present a fabrication method for nano-scale magnetic tunnel junctions (MTJs), employing e-beam lithography and lift-off process assisted by the probe tip of atomic force microscope (AFM). It is challenging to fabricate nano-sized MTJs on small substrates because it is difficult to use chemical mechanical planarization (CMP) process. The AFM-assisted lift-off process enables us to fabricate nano-sized MTJs on small substrates (12.5 mm x 12.5 mm) without CMP process. The e-beam patterning has been done using bi-layer resist, the poly methyl methacrylate (PMMA)/ hydrogen silsesquioxane (HSQ). The PMMA/HSQ resist patterns are used for both the etch mask for ion milling and the self-aligned mask for top contact formation after passivation. The self-aligned mask buried inside a passivation oxide layer, is readily lifted-off by the force exerted by the probe tip. The nano-MTJs (160 nm x 90 nm) fabricated by this method show clear current-induced magnetization switching with a reasonable TMR and critical switching current density.

  17. Ion optics of probe-forming systems on the base of magnetic quadrupole lenses with conical aperture

    Science.gov (United States)

    Ponomarova, A. A.; Vorobjov, G. S.; Ponomarev, A. G.

    2015-04-01

    This paper describes the performance of probe-forming systems based on a new type of magnetic quadrupole lens with a conical aperture (MQL CA). The main difference in the MQL CA from the conventional quadrupole lens with a cylindrical aperture is that the poles in it are not parallel to the lens axis and positioned at a certain angle. The basic advantage of such a lens is that the conical angle of the aperture allows the profile of the longitudinal distribution of the main components of the quadrupole field to be changed. It provides for the changing of the focal length value, displacement of the principal plane relative to the centre of the lens and aberration variations depending on the conical angle. A theoretical study of the ion optics of the probe-forming systems consisting of a triplet MQLs CA was carried out. A comparison of the systems with MQLs CA and conventional systems based on the magnetic quadrupole lens (MQL) with a cylindrical aperture shows the possibility of increasing the acceptance of the first due to using the new type of lens.

  18. Magnetic induction strength on surface of a ferro-medium circular cylinder

    Directory of Open Access Journals (Sweden)

    M. Jin

    2016-09-01

    Full Text Available Based on the Ampere molecular current hypothesis and the Biot–Savart law, a magnetic model on the metal magnetic memory (MMM testing of a specimen is proposed. Relation between magnetic flux leakage (MFL and magnetization of a ferro-medium circular cylinder is set up. We can predict magnetization of material according to the MFL on surface of the circular cylinder.

  19. Surface Photochemistry: Benzophenone as a Probe for the Study of Modified Cellulose Fibres

    Directory of Open Access Journals (Sweden)

    L. F. Vieira Ferreira

    2007-01-01

    Full Text Available This work reports the use of benzophenone, a very well characterized probe, to study new hosts (i.e., modified celluloses grafted with alkyl chains bearing 12 carbon atoms by surface esterification. Laser-induced room temperature luminescence of air-equilibrated or argon-purged solid powdered samples of benzophenone adsorbed onto the two modified celluloses, which will be named C12-1500 and C12-1700, revealed the existence of a vibrationally structured phosphorescence emission of benzophenone in the case where ethanol was used for sample preparation, while a nonstructured emission of benzophenone exists when water was used instead of ethanol. The decay times of the benzophenone emission vary greatly with the solvent used for sample preparation and do not change with the alkylation degree in the range of 1500–1700 micromoles of alkyl chains per gram of cellulose. When water was used as a solvent for sample preparation, the shortest lifetime for the benzophenone emission was observed; this result is similar to the case of benzophenone adsorbed onto the “normal” microcrystalline cellulose surface, with this latter case previously reported by Vieira Ferreira et al. in 1995. This is due to the more efficient hydrogen abstraction reaction from the glycoside rings of cellulose when compared with hydrogen abstraction from the alkyl chains of the modified celluloses. Triplet-triplet transient absorption of benzophenone was obtained in both cases and is the predominant absorption immediately after laser pulse, while benzophenone ketyl radical formation occurs in a microsecond time scale both for normal and modified celluloses.

  20. Hadron physics studied at TJNAF with the electro-magnetic and weak probes

    International Nuclear Information System (INIS)

    Kox, S.

    2005-01-01

    This contribution presents general features of the hadron physics program developed at the Thomas Jefferson Laboratory. This is made using the EM and Weak probes provided by the electron beams of the CEBAF accelerator and address mostly the non-perturbative regime of QCD. (author)

  1. Probing the mechanical properties, conformational changes, and interactions of nucleic acids with magnetic tweezers.

    Science.gov (United States)

    Kriegel, Franziska; Ermann, Niklas; Lipfert, Jan

    2017-01-01

    Nucleic acids are central to the storage and transmission of genetic information. Mechanical properties, along with their sequence, both enable and fundamentally constrain the biological functions of DNA and RNA. For small deformations from the equilibrium conformations, nucleic acids are well described by an isotropic elastic rod model. However, external forces and torsional strains can induce conformational changes, giving rise to a complex force-torque phase diagram. This review focuses on magnetic tweezers as a powerful tool to precisely determine both the elastic parameters and conformational transitions of nucleic acids under external forces and torques at the single-molecule level. We review several variations of magnetic tweezers, in particular conventional magnetic tweezers, freely orbiting magnetic tweezers and magnetic torque tweezers, and discuss their characteristic capabilities. We then describe the elastic rod model for DNA and RNA and discuss conformational changes induced by mechanical stress. The focus lies on the responses to torque and twist, which are crucial in the mechanics and interactions of nucleic acids and can directly be measured using magnetic tweezers. We conclude by highlighting several recent studies of nucleic acid-protein and nucleic acid-small-molecule interactions as further applications of magnetic tweezers and give an outlook of some exciting developments to come. Copyright © 2016. Published by Elsevier Inc.

  2. Electrostatic surface waves on a magnetized quantum plasma half-space

    Energy Technology Data Exchange (ETDEWEB)

    Moradi, Afshin, E-mail: a.moradi@kut.ac.ir [Department of Engineering Physics, Kermanshah University of Technology, Kermanshah, Iran and Department of Nano Sciences, Institute for Studies in Theoretical Physics and Mathematics (IPM), Tehran (Iran, Islamic Republic of)

    2016-03-15

    A theory of electrostatic surface waves on a quantum plasma half-space is developed with the inclusion of external magnetic field effects for the geometry in which the magnetic field is parallel to the surface and the direction of propagation is perpendicular to the magnetic field. A general analytical expression for dispersion relation of surface waves is obtained by solving Poisson and quantum magnetohydrodynamic equations with appropriate quantum boundary conditions.

  3. Measurement of in-plane magnetic relaxation in RE-123 coated conductors by use of scanning Hall probe microscopy

    International Nuclear Information System (INIS)

    Shiohara, K.; Higashikawa, K.; Inoue, M.; Kiss, T.; Iijima, Y.; Saitoh, T.; Yoshizumi, M.; Izumi, T.

    2013-01-01

    Highlights: ► We have investigated electric field criterion of in-plane critical current density. ► We could measure magnetic relaxation in a remanent state. ► The SHPM results show good agreement with the measurements by the 4-probe method. -- Abstract: We have investigated electric field criterion of in-plane critical current density in a coated conductor characterized by scanning Hall-probe microscopy (SHPM). From remanent field distribution and its relaxation measurements, we could obtain critical current distribution and induced electric field simultaneously by considering the Biot-Savart law and the Faraday’s law, respectively. These results lead us to evaluate a distribution of local critical current density and the corresponding criterion of electric field. As a result, it was found that the electric field criterion for the SHPM analysis was several orders lower than that used in the conventional 4-probe resistive method. However, the data point obtained by the SHPM shows good agreement with E–J curve analytically extended from the measurements by the 4-probe method. This means that we could characterize in-plane distribution of critical current density in a coated conductor at an electric field criterion quantitatively by this method in a nondestructive manner. These findings will be very important information since the uniformity of local critical current density in a coated conductor at extremely low electric fields is a key issue (1) especially for DC applications, (2) for quality control of coated conductors, and (3) for the standardization of the characterization of critical current among different methods

  4. Three Dimensional Imaging of Helicon Wave Fields Via Magnetic Induction Probes

    Science.gov (United States)

    2009-07-13

    field Gauss bz radial magnetic field Gauss B0 magnetic field strength Tesla or Gauss c speed of light m/s cs acoustic velocity...eV ΦB magnetic flux Tesla -m2 λ0 mean free path or beam width m or cm λD Debye length m or cm λHelicon helicon wavelength m or cm...locations Turbo Pump Chamber Convectron vent valve Latched door Latched door Roughing Pump 0.5 meter 1.0 meter Cold Cathode Foreline Convectron

  5. Noncollinear Spin Structure in Fe--Ni Invar Alloy Probed by Magnetic EXAFS at High Pressure

    Science.gov (United States)

    Matsumoto, Ken; Maruyama, Hiroshi; Ishimatsu, Naoki; Kawamura, Naomi; Mizumaki, Masaichiro; Irifune, Tetsuo; Sumiya, Hitoshi

    2011-02-01

    To examine theoretical models of the Invar effect, X-ray magnetic circular dichroism and magnetic extended X-ray absorption fine structure (MEXAFS) measurements are performed under high pressures at the Fe and Ni K-edges in 35.4 at. % Ni--Fe alloy. An oscillatory MEXAFS signal is observed up to 6 GPa. Its amplitude significantly decreases with increasing pressure. The magnetic component of the radial distribution function, obtained by taking the Fourier transform, shows a different reduction in the ferromagnetic correlations of Fe and Ni absorbing atoms. The present results are favorable to the noncollinear spin structure picture rather than the Fe 2γ-state model.

  6. Development of Neutron Probes for Characterization of Hazardous Materials in the Sub-surface Medium

    International Nuclear Information System (INIS)

    Keegan, R.P.; McGrath, C.A.; Lopez, J.C.

    2002-01-01

    Neutron probes are being developed at the Idaho National Engineering and Environmental Laboratory (INEEL) for the detection, identification and quantification of hazardous materials in the ground. Such materials include plutonium, uranium, americium, chlorine and fluorine. Both a Neutron Gamma (NG) probe and a Prompt Fission Neutron (PFN) probe are being developed. The NG probe is used primarily for nuclide identification and quantification measurements. The PFN is used mostly for the detection and measurement of fissile material, but also for the determination of thermal neutron macroscopic absorption cross sections of the various elements comprising the ground matrix. Calibration of these probes will be carried out at the INEEL using an indoor facility that has been designed for this activity

  7. Circular mode: a new scanning probe microscopy method for investigating surface properties at constant and continuous scanning velocities.

    Science.gov (United States)

    Nasrallah, Hussein; Mazeran, Pierre-Emmanuel; Noël, Olivier

    2011-11-01

    In this paper, we introduce a novel scanning probe microscopy mode, called the circular mode, which offers expanded capabilities for surface investigations especially for measuring physical properties that require high scanning velocities and/or continuous displacement with no rest periods. To achieve these specific conditions, we have implemented a circular horizontal displacement of the probe relative to the sample plane. Thus the relative probe displacement follows a circular path rather than the conventional back and forth linear one. The circular mode offers advantages such as high and constant scanning velocities, the possibility to be combined with other classical operating modes, and a simpler calibration method of the actuators generating the relative displacement. As application examples of this mode, we report its ability to (1) investigate the influence of scanning velocity on adhesion forces, (2) measure easily and instantly the friction coefficient, and (3) generate wear tracks very rapidly for tribological investigations. © 2011 American Institute of Physics

  8. Planetary Magnetism

    International Nuclear Information System (INIS)

    Russell, C.T.

    1980-01-01

    Planetary spacecraft have now probed the magnetic fields of all the terrestrial planets, the moon, Jupiter, and Saturn. These measurements reveal that dynamos are active in at least four of the planets, Mercury, the earth, Jupiter, and Saturn but that Venus and Mars appear to have at most only very weak planetary magnetic fields. The moon may have once possessed an internal dynamo, for the surface rocks are magnetized. The large satellites of the outer solar system are candidates for dynamo action in addition to the large planets themselves. Of these satellites the one most likely to generate its own internal magnetic field is Io

  9. Probing a dusty magnetized plasma with self-excited dust-density waves

    Science.gov (United States)

    Tadsen, Benjamin; Greiner, Franko; Piel, Alexander

    2018-03-01

    A cloud of nanodust particles is created in a reactive argon-acetylene plasma. It is then transformed into a dusty magnetized argon plasma. Plasma parameters are obtained with the dust-density wave diagnostic introduced by Tadsen et al. [Phys. Plasmas 22, 113701 (2015), 10.1063/1.4934927]. A change from an open to a cylindrically enclosed nanodust cloud, which was observed earlier, can now be explained by a stronger electric confinement if a vertical magnetic field is present. Using two-dimensional extinction measurements and the inverse Abel transform to determine the dust density, a redistribution of the dust with increasing magnetic induction is found. The dust-density profile changes from being peaked around the central void to being peaked at an outer torus ring resulting in a hollow profile. As the plasma parameters cannot explain this behavior, we propose a rotation of the nanodust cloud in the magnetized plasma as the origin of the modified profile.

  10. Probing spin frustration in high-symmetry magnetic nanomolecules by inelastic neutron scattering

    DEFF Research Database (Denmark)

    Garlea, V.O.; Nagler, S.E.; Zarestky, J.L.

    2006-01-01

    Low temperature inelastic neutron scattering studies have been performed to characterize the low energy magnetic excitation spectrum of the magnetic nanomolecule {Mo(72)Fe(30)}. This unique highly symmetric cluster features spin frustration and is one of the largest discrete magnetic molecules...... of the temperature dependence of the observed neutron scattering are explained by a quantum model of the frustrated spin cluster. However, no satisfactory theoretical explanation is yet available for the observed magnetic field dependence....... studied to date by inelastic neutron scattering. The 30 s=5/2 Fe(III) ions, embedded in a spherical polyoxomolybdate molecule, occupy the vertices of an icosidodecahedron and are coupled via nearest-neighbor antiferromagnetic interactions. The overall energy scale of the excitation and the gross features...

  11. Heat transfer control in a plane magnetic fluid layer with a free surface

    International Nuclear Information System (INIS)

    Bashtovoi, V.G.; Pogirnitskaya, S.G.; Reks, A.G.

    1993-01-01

    The heat transfer mechanisms that are specific to a magnetic liquid have been already investigated extensively. The high sensitivity of the free magnetic liquid surface to the external magnetic field introduces a new feature into the heat transfer process. In the present work, the authors have investigated the possibility of controlling the heat transfer through the phenomenon of magnetic liquid surface instability in a uniform magnetic field. The conditions for heat transfer through a chamber, partially filled with a magnetic liquid, are governed by the characteristics of the free liquid surface and by its stability and development in the supercritical magnetic fields. The authors consider a model two-dimensional problem of heat transfer through a two-layer medium consisting of horizontally situated immiscible layers of magnetic and nonmagnetic liquids with given thermal conductivities. In the absence of an external magnetic field, the interface of the liquids represents a plane surface. In fields which exceed the critical magnitude, the interface is deformed along the wave. As the field intensity is increased, the amplitude of interface distortion becomes larger. The two-dimensional shape of the free magnetic liquid surface may be realized experimentally using two plane layers of magnetic and nonmagnetic liquids in a uniform magnetic field tangent to the interface of the component layers. 7 refs., 9 figs

  12. The Stellar Imager (SI) - A Mission to Resolve Stellar Surfaces, Interiors, and Magnetic Activity

    International Nuclear Information System (INIS)

    Christensen-Dalsgaard, Joergen; Carpenter, Kenneth G; Schrijver, Carolus J; Karovska, Margarita

    2011-01-01

    The Stellar Imager (SI) is a space-based, UV/Optical Interferometer (UVOI) designed to enable 0.1 milli-arcsecond (mas) spectral imaging of stellar surfaces and of the Universe in general. It will also probe via asteroseismology flows and structures in stellar interiors. SI will enable the development and testing of a predictive dynamo model for the Sun, by observing patterns of surface activity and imaging of the structure and differential rotation of stellar interiors in a population study of Sun-like stars to determine the dependence of dynamo action on mass, internal structure and flows, and time. SI's science focuses on the role of magnetism in the Universe and will revolutionize our understanding of the formation of planetary systems, of the habitability and climatology of distant planets, and of many magneto-hydrodynamically controlled processes in the Universe. SI is a 'Landmark/Discovery Mission' in the 2005 Heliophysics Roadmap, an implementation of the UVOI in the 2006 Astrophysics Strategic Plan, and a NASA Vision Mission ('NASA Space Science Vision Missions' (2008), ed. M. Allen). We present here the science goals of the SI Mission, a mission architecture that could meet those goals, and the technology development needed to enable this mission. Additional information on SI can be found at: http://hires.gsfc.nasa.gov/si/.

  13. Ultrahigh energy cosmic ray probes of large scale structure and magnetic fields

    International Nuclear Information System (INIS)

    Sigl, Guenter; Miniati, Francesco; Ensslin, Torsten A.

    2004-01-01

    We study signatures of a structured universe in the multi-pole moments, auto-correlation function, and cluster statistics of ultrahigh energy cosmic rays above 10 19 eV. We compare scenarios where the sources are distributed homogeneously or according to the baryon density distribution obtained from a cosmological large scale structure simulation. The influence of extragalactic magnetic fields is studied by comparing the case of negligible fields with fields expected to be produced along large scale shocks with a maximal strength consistent with observations. We confirm that strongly magnetized observers would predict considerable anisotropy on large scales, which is already in conflict with current data. In the best fit scenario only the sources are strongly magnetized, although deflection can still be considerable, of order 20 deg. up to 10 20 eV, and a pronounced GZK cutoff is predicted. We then discuss signatures for future large scale full-sky detectors such as the Pierre Auger and EUSO projects. Auto-correlations are sensitive to the source density only if magnetic fields do not significantly affect propagation. In contrast, for a weakly magnetized observer, degree scale auto-correlations below a certain level indicate magnetized discrete sources. It may be difficult even for next generation experiments to distinguish between structured and unstructured source distributions

  14. Spin excitations in 3D molecular magnets probed by neutron scattering

    International Nuclear Information System (INIS)

    Bordallo, H.N.; Goremychkin, E.; Chapon, L.C.; Manson, J.L.; Cook, J.C.; Lee, S.H.; Copley, J.R.D.; Yildirim, T.; Kern, S.

    2002-01-01

    The emerging field of molecular magnetism constitutes a new branch of materials science that deals with the magnetic properties of molecules, or assemblies of molecules, that contain magnetic centers. The growing interest in understanding the origin of the magnetic ordering in these materials is to obtain novel multiproperty molecular magnetic materials with high transition temperatures. Molecules based on the dicyanamide ion [N≡C-N-C≡N], abbreviated (dca), such as M(dca) 2 [M=Mn, Ni], have shown interesting bulk properties that prompted our inelastic neutron scattering (INS) studies. While the Mn 2+ ion is isotropic because of its L=0 configuration, the isostructural Ni analog has S=1 and demonstrates marked single-ion anisotropy. Mn(dca) 2 is a canted antiferromagnet below 16 K, while Ni(dca) 2 is a ferromagnet below 21 K. INS has been used to investigate the magnetic excitations in Mn(dca) 2 and Ni(dca) 2 . For Mn(dca) 2 , a Heisenberg model gives good correspondence with the experimental results. (orig.)

  15. Spin excitations in 3D molecular magnets probed by neutron scattering

    CERN Document Server

    Bordallo, H N; Chapon, L C; Manson, J L; Cook, J C; Lee, S H; Copley, J R D; Yildirim, T; Kern, S

    2002-01-01

    The emerging field of molecular magnetism constitutes a new branch of materials science that deals with the magnetic properties of molecules, or assemblies of molecules, that contain magnetic centers. The growing interest in understanding the origin of the magnetic ordering in these materials is to obtain novel multiproperty molecular magnetic materials with high transition temperatures. Molecules based on the dicyanamide ion [N ident to C-N-C ident to N], abbreviated (dca), such as M(dca) sub 2 [M=Mn, Ni], have shown interesting bulk properties that prompted our inelastic neutron scattering (INS) studies. While the Mn sup 2 sup + ion is isotropic because of its L=0 configuration, the isostructural Ni analog has S=1 and demonstrates marked single-ion anisotropy. Mn(dca) sub 2 is a canted antiferromagnet below 16 K, while Ni(dca) sub 2 is a ferromagnet below 21 K. INS has been used to investigate the magnetic excitations in Mn(dca) sub 2 and Ni(dca) sub 2. For Mn(dca) sub 2 , a Heisenberg model gives good corr...

  16. Inducing spin-dependent tunneling to probe magnetic correlations in optical lattices

    DEFF Research Database (Denmark)

    Pedersen, Kim Georg Lind; Andersen, Brian Møller; Bruun, Georg Morten

    2012-01-01

    We suggest a simple experimental method for probing antiferromagnetic spin correlations of two-component Fermi gases in optical lattices. The method relies on a spin selective Raman transition to excite atoms of one spin species to their first excited vibrational mode where the tunneling is large....... The resulting difference in the tunneling dynamics of the two spin species can then be exploited, to reveal the spin correlations by measuring the number of doubly occupied lattice sites at a later time. We perform quantum Monte Carlo simulations of the spin system and solve the optical lattice dynamics...... numerically to show how the timed probe can be used to identify antiferromagnetic spin correlations in optical lattices....

  17. Local structures of mesoporous bioactive glasses and their surface alterations in vitro: inferences from solid-state nuclear magnetic resonance

    Science.gov (United States)

    Gunawidjaja, Philips N.; Mathew, Renny; Lo, Andy Y. H.; Izquierdo-Barba, Isabel; García, Ana; Arcos, Daniel; Mattias Edén, María Vallet-Regí

    2012-01-01

    We review the benefits of using 29Si and 1H magic angle spinning (MAS) nuclear magnetic resonance (NMR) spectroscopy for probing the local structures of both bulk and surface portions of mesoporous bioactive glasses (MBGs) of the CaO–SiO2−(P2O5) system. These mesoporous materials exhibit an ordered pore arrangement, and are promising candidates for improved bone and tooth implants. We discuss experimental MAS NMR results from three MBGs displaying different Ca, Si and P contents: the 29Si NMR spectra were recorded either directly by employing radio-frequency pulses to 29Si, or by magnetization transfers from neighbouring protons using cross polarization, thereby providing quantitative information about the silicate speciation present in the pore wall and at the MBG surface, respectively. The surface modifications were monitored for the three MBGs during their immersion in a simulated body fluid (SBF) for intervals between 30 min and one week. The results were formulated as a reaction sequence describing the interconversions between the distinct silicate species. We generally observed a depletion of Ca2+ ions at the MBG surface, and a minor condensation of the silicate-surface network over one week of SBF soaking. PMID:22349247

  18. Probing surface distributions of α clusters in 20Ne via α -transfer reaction

    Science.gov (United States)

    Fukui, Tokuro; Taniguchi, Yasutaka; Suhara, Tadahiro; Kanada-En'yo, Yoshiko; Ogata, Kazuyuki

    2016-03-01

    Background: Direct evidence of the α -cluster manifestation in bound states has not been obtained yet, although a number of experimental studies were carried out to extract the information of the clustering. In particular in conventional analyses of α -transfer reactions, there exist a few significant problems on reaction models, which are insufficient to qualitatively discuss the cluster structure. Purpose: We aim to verify the manifestation of the α -cluster structure from observables. As the first application, we plan to extract the spatial information of the cluster structure of the 20Ne nucleus in its ground state through the cross section of the α -transfer reaction 16O(6Li,d )20Ne. Methods: For the analysis of the transfer reaction, we work with the coupled-channel Born approximation (CCBA) approach, in which the breakup effect of 6Li is explicitly taken into account by means of the continuum-discretized coupled-channel method based on the three-body α +d +16O model. The two methods are adopted to calculate the overlap function between 20Ne and α +16O ; one is the microscopic cluster model (MCM) with the generator coordinate method, and the other is the phenomenological two-body potential model (PM). Results: We show that the CCBA calculation with the MCM wave function gives a significant improvement of the theoretical result on the angular distribution of the transfer cross section, which is consistent with the experimental data. Employing the PM, it is discussed which region of the cluster wave function is probed on the transfer cross section. Conclusions: It is found that the surface region of the cluster wave function is sensitive to the cross section. The present work is situated as the first step in obtaining important information to systematically investigate the cluster structure.

  19. Radioactive probe studies of coordination modes of heavy metal ions from natural waters to functionalized magnetic nanoparticles

    CERN Multimedia

    Carvalho Soares, J; Lopes, C; Araujo, J

    We propose to use PAC, Perturbed Angular Correlations, to study the local environment of ionic species (Hg$^{2+}$, Cd$^{2+}$) coordinated on functionalized magnetic nanoparticles. Studies include the analysis of different nanoparticle sizes (30-100nm), and the monitoring of time/steps dependence of the coordination of those cations at the nanoparticle surfaces. Combined with theoretical calculations, the obtained data will support the understanding of local coordination modes, which is essential to help to improve methods of magnetically assisted separation of such hazardous contaminants from water.

  20. Magnetic fluid hyperthermia probed by both calorimetric and dynamic hysteresis measurements

    Energy Technology Data Exchange (ETDEWEB)

    Guibert, Clément; Fresnais, Jérôme; Peyre, Véronique; Dupuis, Vincent, E-mail: vincent.dupuis@upmc.fr

    2017-01-01

    In this paper, we report an investigation of magnetic fluid hyperthermia (MFH) using combined calorimetric and newly implemented dynamic hysteresis measurements for two sets of well characterized size-sorted maghemite nanoparticles (with diameters of about 10 nm and 20 nm) dispersed in water and in glycerol. Our primary goal was to assess the influence of viscosity on the heating efficiency of magnetic nanoparticles described in terms of specific loss power (SLP or specific absorption rate, SAR) and dynamic hysteresis. In particular, we aimed to investigate how this SLP depends on the transition from Néelian to Brownian behavior of nanoparticles expected to occur between 10 nm and 20 nm (for maghemite) and dependent on the viscosity. While we observed a good agreement between calorimetric and dynamic hysteresis measurements, we found that the SLP measured for the different systems do not depend noticeably on the viscosity of solvent. Calculations performed according to Rosensweig's linear model [1] allow us to quantitatively reproduce our results at low field intensities, provided we use a value for the magnetic anisotropy constant much smaller than the one commonly used in the literature. This raises the question of the temperature dependance of the magnetic anisotropy constant and its relevance for a quantitative description of MFH. - Highlights: • Dynamic hysteresis measurements are a promising tool to study magnetic hyperthermia. • Dynamic hysteresis cycles can be reproduced using a simple model. • The effect of viscosity on hyperthermia of maghemite is weaker than expected.

  1. Computational analysis of transcranial magnetic stimulation in the presence of deep brain stimulation probes

    Science.gov (United States)

    Syeda, F.; Holloway, K.; El-Gendy, A. A.; Hadimani, R. L.

    2017-05-01

    Transcranial Magnetic Stimulation is an emerging non-invasive treatment for depression, Parkinson's disease, and a variety of other neurological disorders. Many Parkinson's patients receive the treatment known as Deep Brain Stimulation, but often require additional therapy for speech and swallowing impairment. Transcranial Magnetic Stimulation has been explored as a possible treatment by stimulating the mouth motor area of the brain. We have calculated induced electric field, magnetic field, and temperature distributions in the brain using finite element analysis and anatomically realistic heterogeneous head models fitted with Deep Brain Stimulation leads. A Figure of 8 coil, current of 5000 A, and frequency of 2.5 kHz are used as simulation parameters. Results suggest that Deep Brain Stimulation leads cause surrounding tissues to experience slightly increased E-field (Δ Emax =30 V/m), but not exceeding the nominal values induced in brain tissue by Transcranial Magnetic Stimulation without leads (215 V/m). The maximum temperature in the brain tissues surrounding leads did not change significantly from the normal human body temperature of 37 °C. Therefore, we ascertain that Transcranial Magnetic Stimulation in the mouth motor area may stimulate brain tissue surrounding Deep Brain Stimulation leads, but will not cause tissue damage.

  2. Templating Biomineralization: Surface Directed Protein Self-assembly and External Magnetic Field Stimulation of Osteoblasts

    Science.gov (United States)

    Ba, Xiaolan

    Biomineralization is a wide-spread phenomenon in the biological systems, which is the process of mineral formation by organisms through interaction between its organic contents and the inorganic minerals. The process is essential in a broad spectrum of biological phenomena ranging from bone and tooth formation to pathological mineralization under hypoxic conditions or cancerous formations. In this thesis I studied biomineralization at the earliest stages in order to obtain a better understanding of the fundamental principals involved. This knowledge is essential if we want to engineer devices which will increase bone regeneration or prevent unwanted mineral deposits. Extracellular matrix (ECM) proteins play an essential role during biomineralization in bone and engineered tissues. In this dissertation, I present an approach to mimic the ECM in vitro to probe the interactions of these proteins with calcium phosphate mineral and with each other. Early stage of mineralization is investigated by mechanical properties of the protein fibers using Scanning Probe Microscopy (SPM) and Shear Modulation Force Microscopy (SMFM). The development of mineral crystals on the protein matrices is also characterized by Scanning Electron Microscopy (SEM), Transmission Electron Microscopy (TEM) and Grazing Incidence X-ray Diffraction (GIXRD). The results demonstrate complementary actions of the two ECM proteins to collect cations and template calcium phosphate mineral, respectively. Magnets have been clinically used as an "induction source" in various bone or orthodontic treatments. However, the mechanism and effects of magnetic fields remain unclear. In this dissertation, I also undertake the present investigation to study the effects of 150 mT static magnetic fields (SMF) on ECM development and cell biomineralization using MC3T3-E1 osteobalst-like cells. Early stage of biomineralization is characterized by SPM, SMFM and confocal laser scanning microscopy (CSLM). Late stage of

  3. Chemical, electronic, and magnetic structure of LaFeCoSi alloy: Surface and bulk properties

    Energy Technology Data Exchange (ETDEWEB)

    Lollobrigida, V. [Dipartimento di Scienze, Università Roma Tre, I-00146 Rome (Italy); Dipartimento di Matematica e Fisica, Università Roma Tre, I-00146 Rome (Italy); Basso, V.; Kuepferling, M.; Coïsson, M.; Olivetti, E. S.; Celegato, F. [Istituto Nazionale di Ricerca Metrologica (INRIM), I-10135 Torino (Italy); Borgatti, F. [CNR, Istituto per lo Studio dei Materiali Nanostrutturati (ISMN), I-40129 Bologna (Italy); Torelli, P.; Panaccione, G. [CNR, Istituto Officina dei Materiali (IOM), Lab. TASC, I-34149 Trieste (Italy); Tortora, L. [Laboratorio di Analisi di Superficie, Dipartimento di Matematica e Fisica, Università Roma Tre, I-00146 Rome (Italy); Dipartimento di Ingegneria Meccanica, Università Tor Vergata, I-00133 Rome (Italy); Stefani, G.; Offi, F. [Dipartimento di Scienze, Università Roma Tre, I-00146 Rome (Italy)

    2014-05-28

    We investigate the chemical, electronic, and magnetic structure of the magnetocaloric LaFeCoSi compound with bulk and surface sensitive techniques. We put in evidence that the surface retains a soft ferromagnetic behavior at temperatures higher than the Curie temperature of the bulk due to the presence of Fe clusters at the surface only. This peculiar magnetic surface effect is attributed to the exchange interaction between the ferromagnetic Fe clusters located at the surface and the bulk magnetocaloric alloy, and it is used here to monitor the magnetic properties of the alloy itself.

  4. Chemical, electronic, and magnetic structure of LaFeCoSi alloy: Surface and bulk properties

    International Nuclear Information System (INIS)

    Lollobrigida, V.; Basso, V.; Kuepferling, M.; Coïsson, M.; Olivetti, E. S.; Celegato, F.; Borgatti, F.; Torelli, P.; Panaccione, G.; Tortora, L.; Stefani, G.; Offi, F.

    2014-01-01

    We investigate the chemical, electronic, and magnetic structure of the magnetocaloric LaFeCoSi compound with bulk and surface sensitive techniques. We put in evidence that the surface retains a soft ferromagnetic behavior at temperatures higher than the Curie temperature of the bulk due to the presence of Fe clusters at the surface only. This peculiar magnetic surface effect is attributed to the exchange interaction between the ferromagnetic Fe clusters located at the surface and the bulk magnetocaloric alloy, and it is used here to monitor the magnetic properties of the alloy itself.

  5. Using magnetic nanoparticles to probe protein damage in ferritin caused by freeze concentration

    Directory of Open Access Journals (Sweden)

    E. F. Chagas

    2015-11-01

    Full Text Available We demonstrate a method for monitoring the damage caused to a protein during freeze-thawing in the presence of glycerol, a cryo-protectant. For this work we synthesized magnetite nanoparticles doped with 2.5% cobalt inside the protein ferritin (CMF, dissolved them in different concentration glycerol solutions and measured their magnetization after freezing in a high applied field (5 T. As the temperature was raised, a step-like decrease in the sample magnetization was observed, corresponding to the onset of Brownian relaxation as the viscosity of the freeze-concentrated glycerol solution decreased. The position of the step reveals changes to the protein hydrodynamic radius that we attribute to protein unfolding, while its height depends on how much protein is trapped by ice during freeze concentration. Changes to the protein hydrodynamic radius are confirmed by dynamic light scattering (DLS measurements, but unlike DLS, the magnetic measurements can provide hydrodynamic data while the solution remains mainly frozen.

  6. Probing spin correlations with phonons in the strongly frustrated magnet ZnCr2O4.

    Science.gov (United States)

    Sushkov, A B; Tchernyshyov, O; Ratcliff, W; Cheong, S W; Drew, H D

    2005-04-08

    The spin-lattice coupling plays an important role in strongly frustrated magnets. In ZnCr2O4, an excellent realization of the Heisenberg antiferromagnet on the pyrochlore network, a lattice distortion relieves the geometrical frustration through a spin-Peierls-like phase transition at T(c)=12.5 K. Conversely, spin correlations strongly influence the elastic properties of a frustrated magnet. By using infrared spectroscopy and published data on magnetic specific heat, we demonstrate that the frequency of an optical phonon triplet in ZnCr2O4 tracks the nearest-neighbor spin correlations above T(c). The splitting of the phonon triplet below T(c) provides a way to measure the spin-Peierls order parameter.

  7. Using Magnetic Forces to Probe the Gravi-response of Swimming Paramecium

    Science.gov (United States)

    Guevorkian, Karine; Valles, James M., Jr.

    2004-03-01

    Paramecium Caudatum, a single celled ciliate, alters its swimming behavior when subjected to different gravity environments (e.g. centrifugation and micro-gravity). To dissect the mechanisms behind this gravi-response and that of other biological systems, we are developing the use of magnetic body forces as a means of creating a rapidly tunable, simulated variable gravity environment. Since biological materials are weakly diamagnetic, we must subject them to intense inhomogeneous magnetic fields with characteristic field-field gradient products on the order of 16 T^2/cm. We will describe experiments on Paramecium Caudatum in which we adjust their net buoyancy with magnetic forces and measure the resulting changes in their swimming behavior.

  8. A sphericon-shaped magnetic millirobot rolling on a surface actuated by an external wobbling magnetic field

    Directory of Open Access Journals (Sweden)

    Seungmun Jeon

    2017-05-01

    Full Text Available This paper proposes a novel sphericon-shaped magnetic millirobot (SSMM that can roll on a variety of surfaces. The SSMM comprises four identical half cones with a cylindrical magnet inserted into the geometric center. It can roll forward or backward on a surface with repeated rolling cone motions (wobbling motions. Since a rolling SSMM develops its entire surface by means of line contact, a relatively large maximum static friction force can make the SSMM move on a surface steadily and effectively. In this work, a new type of external wobbling magnetic field (EWMF was also derived to manipulate the SSMM’s rolling motions precisely. Then, the controlled rolling motions of prototype SSMMs under various surface conditions were demonstrated to examine the rolling ability of the proposed SSMM.

  9. Eddy current analysis by BEM utilizing loop electric and surface magnetic currents as unknowns

    International Nuclear Information System (INIS)

    Ishibashi, Kazuhisa

    2002-01-01

    The surface integral equations whose unknowns are the surface electric and magnetic currents are widely used in eddy current analysis. However, when the skin depth is thick, computational error is increased especially in obtaining electromagnetic fields near the edge of the conductor. In order to obtain the electromagnetic field accurately, we propose an approach to solve surface integral equations utilizing loop electric and surface magnetic currents as unknowns. (Author)

  10. Nanopatterning on silicon surface using atomic force microscopy with diamond-like carbon (DLC-coated Si probe

    Directory of Open Access Journals (Sweden)

    Zhou Jingfang

    2011-01-01

    Full Text Available Abstract Atomic force microscope (AFM equipped with diamond-like carbon (DLC-coated Si probe has been used for scratch nanolithography on Si surfaces. The effect of scratch direction, applied tip force, scratch speed, and number of scratches on the size of the scratched geometry has been investigated. The size of the groove differs with scratch direction, which increases with the applied tip force and number of scratches but decreases slightly with scratch speed. Complex nanostructures of arrays of parallel lines and square arrays are further fabricated uniformly and precisely on Si substrates at relatively high scratch speed. DLC-coated Si probe has the potential to be an alternative in AFM-based scratch nanofabrication on hard surfaces.

  11. Accounting for Debye sheath expansion for proud Langmuir probes in magnetic confinement fusion plasmas

    Science.gov (United States)

    Tsui, C. K.; Boedo, J. A.; Stangeby, P. C.; TCV Team

    2018-01-01

    A Child-Langmuir law-based method for accounting for Debye sheath expansion while fitting the current-voltage I-V characteristic of proud Langmuir probes (electrodes that extend into the volume of the plasma) is described. For Langmuir probes of a typical size used in tokamak plasmas, these new estimates of electron temperature and ion saturation current density values decreased by up to 60% compared to methods that did not account for sheath expansion. Changes to the collection area are modeled using the Child-Langmuir law and effective expansion perimeter lp, and the model is thus referred to as the "perimeter sheath expansion method." lp is determined solely from electrode geometry, so the method may be employed without prior measurement of the magnitude of the sheath expansion effects for a given Langmuir probe and can be used for electrodes of different geometries. This method correctly predicts the non-saturating ΔI/ΔV slope for cold, low-density plasmas where sheath-expansion effects are strong, as well as for hot plasmas where ΔI/ΔV ˜ 0, though it is shown that the sheath can still significantly affect the collection area in these hot conditions. The perimeter sheath expansion method has several advantages compared to methods where the non-saturating current is fitted: (1) It is more resilient to scatter in the I-V characteristics observed in turbulent plasmas. (2) It is able to separate the contributions to the ΔI/ΔV slope from sheath expansion to that of the high energy electron tail in high Te conditions. (3) It calculates the change in the collection area due to the Debye sheath for conditions where ΔI/ΔV ˜ 0 and for V = Vf.

  12. Accounting for Debye sheath expansion for proud Langmuir probes in magnetic confinement fusion plasmas.

    Science.gov (United States)

    Tsui, C K; Boedo, J A; Stangeby, P C

    2018-01-01

    A Child-Langmuir law-based method for accounting for Debye sheath expansion while fitting the current-voltage I-V characteristic of proud Langmuir probes (electrodes that extend into the volume of the plasma) is described. For Langmuir probes of a typical size used in tokamak plasmas, these new estimates of electron temperature and ion saturation current density values decreased by up to 60% compared to methods that did not account for sheath expansion. Changes to the collection area are modeled using the Child-Langmuir law and effective expansion perimeter l p , and the model is thus referred to as the "perimeter sheath expansion method." l p is determined solely from electrode geometry, so the method may be employed without prior measurement of the magnitude of the sheath expansion effects for a given Langmuir probe and can be used for electrodes of different geometries. This method correctly predicts the non-saturating ΔI/ΔV slope for cold, low-density plasmas where sheath-expansion effects are strong, as well as for hot plasmas where ΔI/ΔV ∼ 0, though it is shown that the sheath can still significantly affect the collection area in these hot conditions. The perimeter sheath expansion method has several advantages compared to methods where the non-saturating current is fitted: (1) It is more resilient to scatter in the I-V characteristics observed in turbulent plasmas. (2) It is able to separate the contributions to the ΔI/ΔV slope from sheath expansion to that of the high energy electron tail in high Te conditions. (3) It calculates the change in the collection area due to the Debye sheath for conditions where ΔI/ΔV ∼ 0 and for V = V f .

  13. Diagnostics of magnetized low temperature plasma by ball-pen probe

    Czech Academy of Sciences Publication Activity Database

    Adámek, Jiří; Peterka, M.; Gyergyek, T.; Kudrna, P.; Tichý, M.

    2012-01-01

    Roč. 57, č. 2 (2012), s. 297-300 ISSN 0029-5922. [International Conference on Research and Applications of Plasmas (PLASMA). Warsaw, 12.09.2011-16.09.2011] R&D Projects: GA ČR GA202/07/0044; GA AV ČR KJB100430901 Institutional research plan: CEZ:AV0Z20430508 Keywords : ball- pen probe * magnetron Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.507, year: 2012 http://www.nukleonika.pl/www/back/full/vol57_2012/v57n2p297f.pdf

  14. Magnetic fluid hyperthermia probed by both calorimetric and dynamic hysteresis measurements

    Science.gov (United States)

    Guibert, Clément; Fresnais, Jérôme; Peyre, Véronique; Dupuis, Vincent

    2017-01-01

    In this paper, we report an investigation of magnetic fluid hyperthermia (MFH) using combined calorimetric and newly implemented dynamic hysteresis measurements for two sets of well characterized size-sorted maghemite nanoparticles (with diameters of about 10 nm and 20 nm) dispersed in water and in glycerol. Our primary goal was to assess the influence of viscosity on the heating efficiency of magnetic nanoparticles described in terms of specific loss power (SLP or specific absorption rate, SAR) and dynamic hysteresis. In particular, we aimed to investigate how this SLP depends on the transition from Néelian to Brownian behavior of nanoparticles expected to occur between 10 nm and 20 nm (for maghemite) and dependent on the viscosity. While we observed a good agreement between calorimetric and dynamic hysteresis measurements, we found that the SLP measured for the different systems do not depend noticeably on the viscosity of solvent. Calculations performed according to Rosensweig's linear model [1] allow us to quantitatively reproduce our results at low field intensities, provided we use a value for the magnetic anisotropy constant much smaller than the one commonly used in the literature. This raises the question of the temperature dependance of the magnetic anisotropy constant and its relevance for a quantitative description of MFH.

  15. Probing spin-polarized tunneling at high bias and temperature with a magnetic tunnel transistor

    NARCIS (Netherlands)

    Park, B.G.; Banerjee, T.; Min, B.C.; Sanderink, Johannes G.M.; Lodder, J.C.; Jansen, R.

    2005-01-01

    The magnetic tunnel transistor (MTT) is a three terminal hybrid device that consists of a tunnel emitter, a ferromagnetic (FM) base, and a semiconductor collector. In the MTT with a FM emitter and a single FM base, spin-polarized hot electrons are injected into the base by tunneling. After

  16. Probing the local, electronic and magnetic structure of matter under extreme conditions of temperature and pressure

    DEFF Research Database (Denmark)

    Torchio, R.; Boccato, S.; Cerantola, V.

    2016-01-01

    In this paper we present recent achievements in the field of investigation of the local, electronic and magnetic structure of the matter under extreme conditions of pressure and temperature. These results were obtained thanks to the coupling of a compact laser heating system to the energy-dispersive...

  17. Spin-orbit interaction in chiral carbon nanotubes probed in pulsed magnetic fields

    NARCIS (Netherlands)

    Jhang, S.H.; Marganska, M.; Skourski, Y.; Preusche, D.; Witkamp, B.; Grifoni, M.; Van der Zant, H.; Wosnitza, J.; Strunk, C.

    2010-01-01

    The magnetoconductance of an open carbon nanotube (CNT)-quantum wire was measured in pulsed magnetic fields. At low temperatures, we find a peculiar split magnetoconductance peak close to the chargeneutrality point. Our analysis of the data reveals that this splitting is intimately connected to the

  18. Infrared lines as probes of solar magnetic features. VIII. Mg I 12 micron diagnostics of sunspots

    NARCIS (Netherlands)

    Bruls, J.H.M.J.; Solanki, S.K.; Rutten, R.J.; Carlsson, M.

    1995-01-01

    Due to their large Zeeman sensitivity, the MgI lines at 12μm are important diagnostics of solar magnetism. The formation of their central emission features is now understood, enabling quantitative modeling and diagnostic application of these lines. We supply the first systematic analysis of solar

  19. Size and surface effects on the magnetism of magnetite and maghemite nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Nikiforov, V. N., E-mail: pppnvn@yandex.ru [Moscow State University (Russian Federation); Ignatenko, A. N.; Irkhin, V. Yu. [Russian Academy of Sciences, Mikheev Institute of Metal Physics, Ural Branch (Russian Federation)

    2017-02-15

    The size effects of magnetite and maghemite nanoparticles on their magnetic properties (magnetic moment, Curie temperature, blocking temperature, etc.) have been investigated. Magnetic separation and centrifugation of an aqueous solution of nanoparticles were used for their separation into fractions; their sizes were measured by atomic force microscopy, dynamic light scattering, and electron microscopy. A change in the size leads to a change in the Curie temperature and magnetic moment per formula unit. Both native nanoparticles and those covered with a bioresorbable layer have been considered. The magnetic properties have been calculated by the Monte Carlo method for the classical Heisenberg model with various bulk and surface magnetic moments.

  20. Reduction process of nitroxyl spin probes used in Overhauser-enhanced magnetic resonance imaging: An ESR study

    Energy Technology Data Exchange (ETDEWEB)

    Meenakumari, V.; Premkumar, S.; Benial, A. Milton Franklin, E-mail: miltonfranklin@yahoo.com [Department of Physics, NMSSVN College, Nagamalai, Madurai-625 019, Tamilnadu (India); Jawahar, A. [Department of Chemistry, NMSSVN College, Nagamalai, Madurai-625 019, Tamilnadu (India)

    2016-05-23

    The Electron spin resonance studies on the reduction process of nitroxyl spin probes were carried out for 1mM {sup 14}N- labeled nitroxyl radicals in pure water and 1 mM concentration of ascorbic acid as a function of time. The electron spin resonance parameters, such as line width, hyperfine coupling constant, g-factor, signal intensity ratio and rotational correlation time were estimated. The 3-carbamoyl-PROXYL radical has narrowest line width and fast tumbling motion compared with 3-carboxy-PROXYL, 4-methoxy-TEMPO, and 4-acetamido-TEMPO radicals. The half life time and decay rate were estimated for 1mM concentration of {sup 14}N- labeled nitroxyl radicals in 1 mM concentration of ascorbic acid. From the results, the 3-carbamoyl-PROXYL has long half life time and high stability compared with 3-carboxy-PROXYL, 4-methoxy-TEMPO and 4-acetamido-TEMPO radicals. Therefore, this study reveals that the 3-carbamoyl-PROXYL radical can act as a good redox sensitive spin probe for Overhauser-enhanced Magnetic Resonance Imaging.

  1. The influence of hydrogen adsorption on magnetic properties of Ni/Cu(001) surface

    Czech Academy of Sciences Publication Activity Database

    Máca, František; Shick, Alexander; Redinger, J.; Podloucky, R.; Weinberger, P.

    2003-01-01

    Roč. 53, č. 1 (2003), s. 33-39 ISSN 0011-4626. [Symposium on Surface Physics /9./. Třešt', 02.09.2002-06.09.2002] R&D Projects: GA AV ČR IAA1010214 Grant - others:HPRN-CT(XE) 2000-00143 Institutional research plan: CEZ:AV0Z1010914 Keywords : surface magnetism * thin films * magnetic anisotropy Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 0.263, year: 2003

  2. Surface Crack Detection for Carbon Fiber Reinforced Plastic Materials Using Pulsed Eddy Current Based on Rectangular Differential Probe

    Directory of Open Access Journals (Sweden)

    Jialong Wu

    2014-01-01

    Full Text Available Aiming at the surface defect inspection of carbon fiber reinforced composite, the differential and the direct measurement finite element simulation models of pulsed eddy current flaw detection were built. The principle of differential pulsed eddy current detection was analyzed and the sensitivity of defect detection was compared through two kinds of measurements. The validity of simulation results was demonstrated by experiments. The simulation and experimental results show that the pulsed eddy current detection method based on rectangular differential probe can effectively improve the sensitivity of surface defect detection of carbon fiber reinforced composite material.

  3. Effect of surface free energy on PDMS transfer in microcontact printing and its application to ToF-SIMS to probe surface energies.

    Science.gov (United States)

    Yang, Li; Shirahata, Naoto; Saini, Gaurav; Zhang, Feng; Pei, Lei; Asplund, Matthew C; Kurth, Dirk G; Ariga, Katsuhiko; Sautter, Ken; Nakanishi, Takashi; Smentkowski, Vincent; Linford, Matthew R

    2009-05-19

    Although polydimethylsiloxane (PDMS) transfer during microcontact printing (microCP) has been observed in previous reports, which generally focused on only one or a few different substrates, in this work we investigate the extent of PDMS transfer onto a series of surfaces with a wide range of hydrophobicities using an uninked, unpatterned PDMS stamp. These surfaces include clean silicon, clean titanium, clean gold, "dirty" silicon, polystyrene, Teflon, surfaces modified with PEG, amino, dodecyl, and hexadecyl monolayers, and also two loose molecular materials. The PDMS transferred onto planar surfaces is, in general, easily detected by wetting and spectroscopic ellipsometry. More importantly, it is detected by time-of-flight secondary ion mass spectrometry (ToF-SIMS) because of the sensitivity of this technique to PDMS. The effect of surface free energy on PDMS transfer in microcontact printing is investigated, and the relationship between the amount of PDMS in ToF-SIMS spectra and the surface tensions of initial surfaces is revealed. We show that PDMS transfer can be applied as a probe of surface free energies using ToF-SIMS, where PDMS preferentially transfers onto more hydrophilic surface features during stamping, with little being transferred onto very hydrophobic surface features. Multivariate curve resolution (MCR) analysis of the ToF-SIMS image data further confirms and clarifies these results. Our data lend themselves to the hypothesis that it is the free energy of the surface that plays a major role in determining the degree of PDMS transfer during microCP.

  4. Growth rate of matter perturbations as a probe of large-scale magnetism

    CERN Document Server

    Giovannini, Massimo

    2011-01-01

    The growth rate of matter perturbations is computed in a magnetized environment for the LambdaCDM and wCDM paradigms. It is argued that the baryons do not necessarily follow into the dark matter potential wells after they are released from the drag of the photons. The baryonic evolution equations inherit a forcing term whose explicit form depends on the plasma description and can be deduced, for instance, in the resistive magnetohydrodynamical approximation. After deriving an analytical expression for the growth rate applicable when dark energy does not cluster, the effects of relativistic corrections and of the inhomogeneities associated with the other species of the plasma are taken into account numerically. The spectral amplitudes and slopes of the stochastic magnetic background are selected to avoid appreciable distortions in the measured temperature and polarization anisotropies of the Cosmic Microwave Background. The growth of structures in the current paradigms of structure formation represents a compl...

  5. Temperature and magnetic field dependence of the Yosida-Kondo resonance for a single magnetic atom adsorbed on a surface

    International Nuclear Information System (INIS)

    Dino, Wilson Agerico; Kasai, Hideaki; Rodulfo, Emmanuel Tapas; Nishi, Mayuko

    2006-01-01

    Manifestations of the Kondo effect on an atomic length scale on and around a magnetic atom adsorbed on a nonmagnetic surface differ depending on the spectroscopic mode of operation of the scanning tunneling microscope. Two prominent signatures of the Kondo effect that can be observed at surfaces are the development of a sharp resonance (Yosida-Kondo resonance) at the Fermi level, which broadens with increasing temperature, and the splitting of this sharp resonance upon application of an external magnetic field. Until recently, observing the temperature and magnetic field dependence has been a challenge, because the experimental conditions strongly depend on the system's critical temperature, the so-called Kondo temperature T K . In order to clearly observe the temperature dependence, one needs to choose a system with a large T K . One can thus perform the experiments at temperatures T K . However, because the applied external magnetic field necessary to observe the magnetic field dependence scales with T K , one needs to choose a system with a very small T K . This in turn means that one should perform the experiments at very low temperatures, e.g., in the mK range. Here we discuss the temperature and magnetic field dependence of the Yosida-Kondo resonance for a single magnetic atom on a metal surface, in relation to recent experimental developments

  6. arXiv Probing large-scale magnetism with the Cosmic Microwave Background

    CERN Document Server

    Giovannini, Massimo

    2018-03-19

    Prior to photon decoupling magnetic random fields of comoving intensity in the nano-Gauss range distort the temperature and the polarization anisotropies of the microwave background, potentially induce a peculiar B-mode power spectrum and may even generate a frequency-dependent circularly polarized V-mode. We critically analyze the theoretical foundations and the recent achievements of an interesting trialogue involving plasma physics, general relativity and astrophysics.

  7. Magnetic field dependence of spatial frequency encoding NMR as probed on an oligosaccharide.

    Science.gov (United States)

    Pitoux, D; Hu, Z; Plainchont, B; Merlet, D; Farjon, J; Bonnaffé, D; Giraud, N

    2015-10-01

    The magnetic field dependence of spatial frequency encoding NMR techniques is addressed through a detailed analysis of (1)H NMR spectra acquired under spatial frequency encoding on an oligomeric saccharide sample. In particular, the influence of the strength of the static magnetic field on spectral and spatial resolutions that are key features of this method is investigated. For this purpose, we report the acquisition of correlation experiments implementing broadband homodecoupling or J-edited spin evolutions, and we discuss the resolution enhancements that are provided by these techniques at two different magnetic fields. We show that performing these experiments at higher field improves the performance of high resolution NMR techniques based on a spatial frequency encoding. The significant resolution enhancements observed on the correlation spectra acquired at very high field make them valuable analytical tools that are suitable for the assignment of (1)H chemical shifts and scalar couplings in molecules with highly crowded spectrum such as carbohydrates. Copyright © 2015 John Wiley & Sons, Ltd.

  8. Probing Magnetism in 2D Molecular Networks after in Situ Metalation by Transition Metal Atoms.

    Science.gov (United States)

    Schouteden, K; Ivanova, Ts; Li, Z; Iancu, V; Janssens, E; Van Haesendonck, C

    2015-03-19

    Metalated molecules are the ideal building blocks for the bottom-up fabrication of, e.g., two-dimensional arrays of magnetic particles for spintronics applications. Compared to chemical synthesis, metalation after network formation by an atom beam can yield a higher degree of control and flexibility and allows for mixing of different types of magnetic atoms. We report on successful metalation of tetrapyridyl-porphyrins (TPyP) by Co and Cr atoms, as demonstrated by scanning tunneling microscopy experiments. For the metalation, large periodic networks formed by the TPyP molecules on a Ag(111) substrate are exposed in situ to an atom beam. Voltage-induced dehydrogenation experiments support the conclusion that the porphyrin macrocycle of the TPyP molecule incorporates one transition metal atom. The newly synthesized Co-TPyP and Cr-TPyP complexes exhibit striking differences in their electronic behavior, leading to a magnetic character for Cr-TPyP only as evidenced by Kondo resonance measurements.

  9. submitter Probing electric and magnetic fields with a Moiré deflectometer

    CERN Document Server

    Lansonneur, P; Demetrio, A; Müller, S R; Nedelec, P; Oberthaler, M K

    2017-01-01

    A new contact-free approach for measuring simultaneously electric and magnetic field is reported, which considers the use of a low energy ion source, a set of three transmission gratings and a position sensitive detector. Recently tested with antiprotons (Aghion et al., 2014) [1] at the CERN Antiproton Decelerator facility, this paper extends the proof of principle of a moiré deflectometer (Oberthaler et al., 1996) [2] for distinguishing electric from magnetic fields and opens the route to precision measurements when one is not limited by the ion source intensity. The apparatus presented, whose resolution is mainly limited by the shot noise is able to measure fields as low as 9 mVm−1 Hz−1/2 for electric component and 100 μG Hz−1/2 for the magnetic component. Scaled to 100 nm pitch for the gratings, accessible with current state-of-the-art technology [3], the moiré fieldmeter would be able to measure fields as low as 22 μVm−1 Hz−1/2 and 0.2 μG Hz−1/2.

  10. AC susceptibility as a tool to probe the dipolar interaction in magnetic nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Landi, Gabriel T., E-mail: gtlandi@gmail.com [Universidade Federal do ABC, 09210-580 Santo André (Brazil); Arantes, Fabiana R. [Universidade Federal do ABC, 09210-580 Santo André (Brazil); Cornejo, Daniel R. [Instituto de Física da Universidade de São Paulo, São Paulo 05508-090 (Brazil); Bakuzis, Andris F. [Instituto de Física, Universidade Federal de Goiás, 74690-900 Goiânia-GO (Brazil); Andreu, Irene; Natividad, Eva [Instituto de Ciencia de Materiales de Aragón (ICMA), CSIC-Universidad de Zaragoza, Zaragoza 50018 (Spain)

    2017-01-01

    The dipolar interaction is known to substantially affect the properties of magnetic nanoparticles. This is particularly important when the particles are kept in a fluid suspension or packed within nano-carriers. In addition to its usual long-range nature, in these cases the dipolar interaction may also induce the formation of clusters of particles, thereby strongly modifying their magnetic anisotropies. In this paper we show how AC susceptibility may be used to obtain information regarding the influence of the dipolar interaction in a sample. We develop a model which includes both aspects of the dipolar interaction and may be fitted directly to the susceptibility data. The usual long-range nature of the interaction is implemented using a mean-field approximation, whereas the particle-particle aggregation is modeled using a distribution of anisotropy constants. The model is then applied to two samples studied at different concentrations. One consists of spherical magnetite nanoparticles dispersed in oil and the other of cubic magnetite nanoparticles embedded on polymeric nanospheres. We also introduce a simple technique to address the presence of the dipolar interaction in a given sample, based on the height of the AC susceptibility peaks for different driving frequencies. - Highlights: We discuss the importance of the dipolar interaction in magnetic nanoparticle samples. It is shown that AC susceptibility may be used to estimate the extent of this interaction. We develop a model that accounts for particle aggregation. The theoretical model is then fitted to distinct magnetite samples.

  11. The Lavoisier mission : A system of descent probe and balloon flotilla for geochemical investigation of the deep atmosphere and surface of Venus

    Science.gov (United States)

    Chassefière, E.; Berthelier, J. J.; Bertaux, J.-L.; Quèmerais, E.; Pommereau, J.-P.; Rannou, P.; Raulin, F.; Coll, P.; Coscia, D.; Jambon, A.; Sarda, P.; Sabroux, J. C.; Vitter, G.; Le Pichon, A.; Landeau, B.; Lognonné, P.; Cohen, Y.; Vergniole, S.; Hulot, G.; Mandéa, M.; Pineau, J.-F.; Bézard, B.; Keller, H. U.; Titov, D.; Breuer, D.; Szego, K.; Ferencz, Cs.; Roos-Serote, M.; Korablev, O.; Linkin, V.; Rodrigo, R.; Taylor, F. W.; Harri, A.-M.

    Lavoisier mission is a joint effort of eight European countries and a technological challenge aimed at investigating the lower atmosphere and the surface of Venus. The mission consists of a descent probe and three balloons to be deployed below the cloud deck. Its main scientific objectives may be summarized as following : (i) composition of the deep atmosphere : noble gas (elemental/isotopic), molecular species (elemental/ isotopic), oxygen fugacity; vertical/horizontal/temporal variability; (ii) infrared spectroscopy and radiometry (molecular composition, radiative transfer); (iii) dynamics of the atmosphere : p, T, acceleration measurements, balloon localization through VLBI, meteorological events signed by acoustic waves, atmospheric mixing as imprinted on radioactive tracers; (iv) surface morphology and mineralogy through near infrared imaging on dayside, surface temperature through NIR imaging on nightside. Additional tentative objectives are search for (a) atmospheric electrical activity (optically, radioelectrically, acoustically), (b) crustal outgassing and/or volcanic activity : acoustic activity, horizontal/vertical distribution of radioactive tracers, (c) seismic activity : acoustic waves transmitted from crust to atmosphere, and (d) remanent and/or intrinsic magnetic field. Lavoisier was proposed to ESA in response to the F2/F3 mission Announcement of Opportunity at the beginning of 2000, but it was not selected for the assessment study. A wide international partnership was created for this occasion, including Finland (FMI), France (IPSL, MAGIE, Université Orsay, IPSN, INPG, CEA, IPGP, Obs. Paris-Meudon), Germany (MPAe, Univ. Muenster), Hungary (KFKI, Univ. Eotvos), Portugal (OAL), Russia (IKI), Spain (IAA), United Kingdom (Univ. Oxford).

  12. Coupling between magnetic field and curvature in Heisenberg spins on surfaces with rotational symmetry

    International Nuclear Information System (INIS)

    Carvalho-Santos, Vagson L.; Dandoloff, Rossen

    2012-01-01

    We study the nonlinear σ-model in an external magnetic field applied on curved surfaces with rotational symmetry. The Euler–Lagrange equations derived from the Hamiltonian yield the double sine-Gordon equation (DSG) provided the magnetic field is tuned with the curvature of the surface. A 2π skyrmion appears like a solution for this model and surface deformations are predicted at the sector where the spins point in the opposite direction to the magnetic field. We also study some specific examples by applying the model on three rotationally symmetric surfaces: the cylinder, the catenoid and the hyperboloid.

  13. Magnetic domains and surface effects in hollow maghemite nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Cabot, Andreu; Alivisatos, A. Paul; Puntes, Victor; Balcells, Lluis; Iglesias, Oscar; Labarta, Amilcar

    2008-09-30

    In the present work, we investigate the magnetic properties of ferrimagnetic and non-interacting maghemite hollow nanoparticles obtained by the Kirkendall effect. From the experimental characterization of their magnetic behavior, we find that polycrystalline hollow maghemite nanoparticles exhibit low blocked-to-superparamagnetic transition temperatures, small magnetic moments, significant coercivities and irreversibility fields, and no magnetic saturation on external magnetic fields up to 5 T. These results are interpreted in terms of the microstructural parameters characterizing the maghemite shells by means of atomistic Monte Carlo simulations of an individual spherical shell. The model comprises strongly interacting crystallographic domains arranged in a spherical shell with random orientations and anisotropy axis. The Monte Carlo simulation allows discernment between the influence of the polycrystalline structure and its hollow geometry, while revealing the magnetic domain arranggement in the different temperataure regimes.

  14. Competition/coexistence of magnetism and superconductivity in iron pnictides probed by muon spin rotation

    International Nuclear Information System (INIS)

    Takeshita, Soshi; Kadono, Ryosuke

    2009-01-01

    The presence of macroscopic phase separation into superconducting and magnetic phases in LaFeAsO 1-x F x and CaFe 1-x Co x AsF is demonstrated by muon spin rotation (μSR) measurement across their phase boundaries (x=0.06 for LaFeAsO 1-x F x and x=0.075-0.15 for CaFe 1-x Co x AsF). In LaFeAsO 0.94 F 0.06 , both magnetism and superconductivity develop simultaneously below a common critical temperature, T m ≅T c ≅18 K, where the magnetism is characterized by strong randomness. A similar, but more distinct segregation of these two phases is observed in CaFe 1-x Co x AsF, where the magnetic phase retains T m close to that of the parent compound (T c m ≅80-120 K) and the superconducting volume fraction is mostly proportional to the Co content x. The close relationship between magnetism and superconductivity is discussed based on these experimental observations. Concerning the superconducting phase, an assessment is made on the anisotropy of the order parameter in the superconducting state of LaFeAsO 1-x F x , CaFe 1-x Co x AsF and Ba 1-x K x Fe 2 As 2 (x=0.4) based on the temperature dependence of superfluid density [n s (T)] measured by μSR. The gap parameter, 2Δ/k B T c , determined from n s (T) exhibits a tendency that values in the hole-doped pnictides (Ba 1-x K x Fe 2 As 2 ) are much greater than those in electron-doped ones (LaFeAsO 1-x F x and CaFe 1-x Co x AsF), suggesting a difference in the coupling to bosons mediating the Cooper pairs between relevant d electron bands.

  15. Rare earth(III) complexes for the development of new magnetic and luminescent probes

    International Nuclear Information System (INIS)

    Nonat, A.

    2007-10-01

    The simultaneous optimisation of the molecular parameters determining the relaxivity (number of coordinated water molecules, water-exchange, rotation dynamics of the whole complex, electronic relaxation, Gd(III)-proton distance) is essential to prepare efficient contrast agents. The aim of this work is on the one hand to design and study complexes with a high number of bound water molecules and to understand the influence of the coordination sphere on the stability and on the electronic relaxation and on the other hand, to use the ligand as a chromophore for the development of luminescent probes for biomedical imaging. We present the structure, the stability and the relaxivity of Gd(III) complexes of two series of tripodal ligands containing picolinate units based either on the 1,4,7-tri-aza-cyclononane ring or on a tertiary amine. These complexes show high relaxivity in water and in serum and can establish a non covalent interaction with serum albumin. The interpretation of the water proton relaxivity with the help of new relaxometric methods based on an auxiliary probe solute has allowed us to show that both the presence of the picolinate groups and the 1,4,7-tri-aza-cyclononane framework can lead to Gd(III) complexes with favourable electronic relaxation properties. This ligands have also been used for Eu(III) and Tb(III) complexation leading to strong luminescence in visible light. Other complexes derived from 8-hydroxyquinoline unit which display a very high luminescence in infrared are also studied. (author)

  16. The effect of external magnetic field on mark size in heat-assisted probe recording on CoNi/Pt multilayers

    NARCIS (Netherlands)

    Zhang, Li; Bain, James A.; Zhu, Jian-Gang; Abelmann, Leon; Onoue, T.

    A method of heat-assisted magnetic recording potentially suitable for probe-based storage systems is characterized. In this work, field-emission current from a scanning tunneling microscope tip isused as the heating source. Pulse voltages of 2-7 V were applied to a CoNi/Pt multilayered film. During

  17. A model for mark size dependence on field emission voltage in heat-assisted magnetic probe recording on CoNi/Pt multilayers

    NARCIS (Netherlands)

    Zhang, Li; Bain, James A.; Zhu, Jian-Gang; Abelmann, Leon; Onoue, T.

    2004-01-01

    A method of heat-assisted magnetic recording (HAMR) potentially suitable for probe-based storage systems is characterized. In this work, field emission current from a scanning tunneling microscope (STM) tip is used as the heating source. Pulse voltages of 2-7 V with a duration of 500 ns were applied

  18. Using Force to Probe Single-Molecule Receptor-Cytoskeletal Anchoring Beneath the Surface of a Living Cell

    DEFF Research Database (Denmark)

    Evans, Evan; Kinoshita, Koji

    2007-01-01

    , K. (2005). Nano-to-micro scale dynamics of P-selectin detachment from leukocyte interfaces: I. Separation of PSGL-1 from the cell cytoskeleton. Biophys. J. 88, 2288-2298]. Retracting cells from receptor-surface attachments at many different speeds revealed that the kinetic rate for receptor......The ligation of cell surface receptors often communicates a signal that initiates a cytoplasmic chemical cascade to implement an important cell function. Less well understood is how physical stress applied to a cell surface adhesive bond propagates throughout the cytostructure to catalyze...... or trigger important steps in these chemical processes. Probing the nanoscale impact of pulling on cell surface bonds, we discovered that receptors frequently detach prematurely from the interior cytostructure prior to failure of the exterior adhesive bond [Evans, E., Heinrich, V., Leung, A., and Kinoshita...

  19. Counting probe

    International Nuclear Information System (INIS)

    Matsumoto, Haruya; Kaya, Nobuyuki; Yuasa, Kazuhiro; Hayashi, Tomoaki

    1976-01-01

    Electron counting method has been devised and experimented for the purpose of measuring electron temperature and density, the most fundamental quantities to represent plasma conditions. Electron counting is a method to count the electrons in plasma directly by equipping a probe with the secondary electron multiplier. It has three advantages of adjustable sensitivity, high sensitivity of the secondary electron multiplier, and directional property. Sensitivity adjustment is performed by changing the size of collecting hole (pin hole) on the incident front of the multiplier. The probe is usable as a direct reading thermometer of electron temperature because it requires to collect very small amount of electrons, thus it doesn't disturb the surrounding plasma, and the narrow sweep width of the probe voltage is enough. Therefore it can measure anisotropy more sensitively than a Langmuir probe, and it can be used for very low density plasma. Though many problems remain on anisotropy, computer simulation has been carried out. Also it is planned to provide a Helmholtz coil in the vacuum chamber to eliminate the effect of earth magnetic field. In practical experiments, the measurement with a Langmuir probe and an emission probe mounted to the movable structure, the comparison with the results obtained in reverse magnetic field by using a Helmholtz coil, and the measurement of ionic sound wave are scheduled. (Wakatsuki, Y.)

  20. Kinetics of ultraviolet and plasma surface modification of poly(dimethylsiloxane) probed by sum frequency vibrational spectroscopy.

    Science.gov (United States)

    Ye, Hongke; Gu, Zhiyong; Gracias, David H

    2006-02-14

    In numerous applications in microfluidics, cell growth, soft lithography, and molecular imprinting, the surface of poly(dimethylsiloxane) (PDMS) is modified from a hydrophobic methyl-terminated surface to a hydrophilic hydroxyl-terminated surface. In this study, we investigated molecular structural and orientational changes at the PDMS-air interface in response to three commonly used surface modification processes: exposure to long-wavelength ultraviolet light (UV), exposure to short-wavelength UV that generates ozone (UVO), and exposure to oxygen plasma (OP). The surfaces of two PDMS compositions (10:1 and 4:1 of base polymer/curing agent) were probed during modification, using monolayer-sensitive IR + visible sum frequency generation (SFG) vibrational spectroscopy, with two different polarization combinations. During PDMS surface modification, the peak intensities of CH3 side groups and CH2 cross-link groups decreased, while peak intensities of Si-OH groups increased. There was no significant change in the average orientation of the CH3 groups on the PDMS surface during modification. The concentration of CH3 groups on the surface decreased exponentially with time, for all three UV, UVO, and OP modification processes, with first order kinetics and time constants of approximately 160, 66, and 0.3 min, respectively. At steady state, residual CH3 groups were detected at the PDMS surface for UV and UVO treatments; however, there were negligible CH3 groups detected after OP modification.

  1. Investigation of the surface potential of TiO2 (110) by frequency-modulation Kelvin probe force microscopy.

    Science.gov (United States)

    Kou, Lili; Li, Yan Jun; Kamijyo, Takeshi; Naitoh, Yoshitaka; Sugawara, Yasuhiro

    2016-12-16

    We investigate the surface potential distribution on a TiO 2 (110)-1 × 1 surface by Kelvin probe force microscopy (KPFM) and atom-dependent bias-distance spectroscopic mapping. The experimental results demonstrate that the local contact potential difference increases on twofold-coordinated oxygen sites, and decreases on OH defects and fivefold-coordinated Ti sites. We propose a qualitative model to explain the origin of the surface potential of TiO 2 (110). We qualitatively calculate the surface potential induced by chemical potential and permanent surface dipole. The calculated results agree with our experimental ones. Therefore, we suggest that the surface potential of TiO 2 (110) is dominated not only by the permanent surface dipole between the tip apex atom and surface, but also by the dipoles induced by the chemical interaction between the tip and sample. The KPFM technique demonstrate the possibility of investigation of the charge transfer phenomenon on TiO 2 surface under gas conditions. It is useful for the elucidation of the mechanism of the catalytic reactions.

  2. On the surface magnetism induced atypical ferromagnetic behavior of cerium oxide (CeO2) nanoparticles

    Science.gov (United States)

    Sakara, M.; Arumugam, S.; Tripathy, S.; Balakumar, S.

    2012-06-01

    An investigation was made on the intrinsic ferromagnetic behavior of nano sized cerium oxide (ceria). The nanosized ceria was prepared by modified sol gel method with crystallite size around 7nm. Structural analysis was done by XRD which showed a single phase, impurity free fluorite type crystal structured of nano ceria. The morphological analysis by FESEM technique showed agglomerated nature of nanoparticles due to their high surface energy. The surface and bulk information was obtained from UV and visible Raman analysis. From Raman studies it was observed that the large surface defect which was the prime reason for the induced surface magnetism in the nano ceria. From magnetization studies by VSM, it was found that if magnetism was associated with the surface defects of the material. The ferromagnetic behavior of nanosized ceria is still under debate. An attempt has taken to explain the same with emphasizing the surface magnetism of ceria nanoparticles.

  3. Liquid Microjunction Surface Sampling Probe Electrospray Mass Spectrometry for Detection of Drugs and Metabolites in Thin Tissue Sections

    Energy Technology Data Exchange (ETDEWEB)

    Van Berkel, Gary J [ORNL; Kertesz, Vilmos [ORNL; Koeplinger, Kenneth A. [Merck Research Laboratories; Vavek, Marissa [Merck Research Laboratories; Kong, Ah-Ng Tony [Rutgers University

    2008-01-01

    A self-aspirating, liquid micro-junction surface sampling probe/electrospray emitter mass spectrometry system was demonstrated for use in the direct analysis of spotted and dosed drugs and their metabolites in thin tissue sections. Proof-of-principle sampling and analysis directly from tissue without the need for sample preparation was demonstrated first by raster scanning a region on a section of rat liver onto which reserpine was spotted. The mass spectral signal from selected reaction monitoring was used to develop a chemical image of the spotted drug on the tissue. The probe was also used to selectively spot sample areas of sagittal whole mouse body tissue sections that had been dosed orally (90 mg/kg) with R,S-sulforaphane 3 hrs prior to sacrifice. Sulforaphane and its glutathione and N-acetyl cysteine conjugates were monitored with selected reaction monitoring and detected in the stomach and various other tissues from the dosed mouse. No signal for these species was observed in the tissue from a control mouse. The same dosed tissue section was used to illustrate the possibility of obtaining a line scan across the whole body section. In total these results illustrate the potential for rapid screening of the distribution of drugs and metabolites in tissue sections with the micro-liquid junction surface sampling probe/electrospray mass spectrometry approach.

  4. Enhanced magnetic field probe array for improved excluded flux calculations on the C-2U advanced beam-driven field-reversed configuration plasma experiment

    Energy Technology Data Exchange (ETDEWEB)

    Roche, T., E-mail: troche@trialphaenergy.com; Thompson, M. C.; Mendoza, R.; Allfrey, I.; Garate, E.; Romero, J.; Douglass, J. [Tri Alpha Energy, P.O. Box 7010, Rancho Santa Margarita, California 92688 (United States)

    2016-11-15

    External flux conserving coils were installed onto the exterior of the C-2U [M. W. Binderbauer et al., Phys. Plasmas 22, 056110 (2015)] confinement vessel to increase the flux confinement time of the system. The 0.5 in. stainless steel vessel wall has a skin time of ∼5 ms. The addition of the external copper coils effectively increases this time to ∼7 ms. This led to better-confined/longer-lived field-reversed configuration (FRC) plasmas. The fringing fields generated by the external coils have the side effect of rendering external field measurements invalid. Such measurements were key to the previous method of excluded flux calculation [M. C. Thompson et al., Rev. Sci. Instrum. 83, 10D709 (2012)]. A new array of B-dot probes and Rogowski coils were installed to better determine the amount of flux leaked out of the system and ultimately provide a more robust measurement of plasma parameters related to pressure balance including the excluded flux radius. The B-dot probes are surface mountable chip inductors with inductance of 33 μH capable of measuring the DC magnetic field and transient field, due to resistive current decay in the wall/coils, when coupled with active integrators. The Rogowski coils measure the total change in current in each external coil (150 A/2 ms). Currents were also actively driven in the external coils. This renders the assumption of total flux conservation invalid which further complicates the analysis process. The ultimate solution to these issues and the record breaking resultant FRC lifetimes will be presented.

  5. Oxidation of hydrogen-passivated silicon surfaces by scanning near-field optical lithography using uncoated and aluminum-coated fiber probes

    DEFF Research Database (Denmark)

    Madsen, Steen; Bozhevolnyi, Sergey I.; Birkelund, Karen

    1997-01-01

    Optically induced oxidation of hydrogen-passivated silicon surfaces using a scanning near-field optical microscope was achieved with both uncoated and aluminum-coated fiber probes. Line scans on amorphous silicon using uncoated fiber probes display a three-peak profile after etching in potassium...

  6. Probing the magnetic ground state of single crystalline Ce3TiSb5

    Science.gov (United States)

    Matin, M.; Kulkarni, R.; Thamizhavel, A.; Dhar, S. K.; Provino, A.; Manfrinetti, P.

    2017-04-01

    Motivated by the report of superconductivity in R3TiSb5 (R  =  La and Ce) and possibly Nd3TiSb5 at  ∼4 K, we grew single crystals of La3TiSb5 and Ce3TiSb5 by the high-temperature solution method using Sn as a flux. While in both compounds we observed a superconducting transition at 3.7 K for resistivity and low-field magnetization, our data conclusively show that it arose from residual Sn flux present in the single crystals. In particular, the heat capacity data do not present any of the anomalies expected from a bulk superconducting transition. The anisotropic magnetic properties of Ce3TiSb5, crystallizing in a hexagonal P63/mcm structure, were studied in detail. We find that the Ce ions in Ce3TiSb5 form a Kondo lattice and exhibited antiferromagnetic ordering at 5.5 K with a reduced moment and a moderately normalized Sommerfeld coefficient of 598 mJ/mol K2. The characteristic single-ion Kondo energy scale was found to be  ∼8 K. The magnetization data were subjected to a crystal electric field (CEF) analysis. The experimentally observed Schottky peak in the 4f-electron heat capacity of Ce3TiSb5 was reproduced fairly well by the energy levels derived from the CEF analysis.

  7. Near-field optical microscopy of localized excitations on rough surfaces: influence of a probe

    DEFF Research Database (Denmark)

    Bozhevolnyi, Sergey I.

    1999-01-01

    Starting from the general principles of near-field optical microscopy. I consider the influence of a probe when being used to image localized dipolar excitations and suggest a way of evaluating the perturbation thus introduced. Using the rigorous microscopic (electric) point-dipole description, I...

  8. A non perturbative optical probe for laser induced fluorescence diagnostics in magnetized plasma

    International Nuclear Information System (INIS)

    Anderegg, F.; Paris, P.J.; Skiff, F.; Good, T.N.; Tran, M.Q.

    1988-01-01

    An 'optical carriage' has been developed to improve plasma access for LIF diganostics. Laser light inducing the fluorescence is transported through an optical fiber to the carriage. A telescope fixed on the carriage collects the plasma fluorescence light and sends it through a fiber bundle to an external PMT. The whole carriage is mounted on rails and can be scanned along and acrosss magnetic field. Wave interferograms and slow rotation of a plasma measured via LIF and optical tagging demonstrate the flexibility of the 'optical carriage'. (author) 4 figs., 8 refs

  9. Fiber optic probe enabled by surface-enhanced Raman scattering for early diagnosis of potential acute rejection of kidney transplant

    Science.gov (United States)

    Chi, Jingmao; Chen, Hui; Tolias, Peter; Du, Henry

    2014-06-01

    We have explored the use of a fiber-optic probe with surface-enhanced Raman scattering (SERS) sensing modality for early, noninvasive and, rapid diagnosis of potential renal acute rejection (AR) and other renal graft dysfunction of kidney transplant patients. Multimode silica optical fiber immobilized with colloidal Ag nanoparticles at the distal end was used for SERS measurements of as-collected urine samples at 632.8 nm excitation wavelength. All patients with abnormal renal graft function (3 AR episodes and 2 graft failure episodes) who were clinically diagnosed independently show common unique SERS spectral features in the urines collected just one day after transplant. SERS-based fiber-optic probe has excellent potential to be a bedside tool for early diagnosis of kidney transplant patients for timely medical intervention of patients at high risk of transplant dysfunction.

  10. Vector Magnetic Fields, Sub surface Stresses and Evolution of ...

    Indian Academy of Sciences (India)

    tribpo

    Abstract. Observations of the strength and spatial distribution of vector magnetic fields in active regions have revealed several fundamental properties of the twist of their magnetic fields. First, the handedness of this twist obeys a hemispheric rule: left handed in the northern hemis phere, right handed in the southern. Second ...

  11. Probing quantum Hall states with single-electron transistors at high magnetic fields

    Science.gov (United States)

    Gustafsson, Martin; Yankowitz, Matthew; Forsythe, Carlos; Zhu, Xiaoyang; Dean, Cory

    The sequence of fractional quantum Hall states in graphene is not yet fully understood, largely due to disorder-induced limitations of conventional transport studies. Measurements of magnetotransport in other 2D crystals are further complicated by the difficulties in making ohmic contact to the materials. On the other hand, bulk electronic compressibility can provide clear signatures of the integer and fractional quantum Hall effects, does not require ohmic contact, and can be localized to regions of low disorder. The single-electron transistor (SET) is a suitable tool for such experiments due to its small size and high charge sensitivity, which allow electric fields penetrating the 2D electron system to be detected locally and with high fidelity. Here we report studies of exfoliated 2D van der Waals materials fully encapsulated in flakes of hexagonal boron nitride. SETs are fabricated lithographically on top of the encapsulation, yielding a structure which lends itself to experiments at high electric and magnetic fields. We demonstrate the method on monolayer graphene, where we observe fractional quantum Hall states at all filling factors ν = n / 3 up to n = 17 and extract their associated energy gaps for magnetic fields up to 31 tesla.

  12. Eddy current magnetic bias x-probe qualification and inspection of steam generator Monel 400 tubing in Pickering Nuclear Generating Station

    International Nuclear Information System (INIS)

    Lepine, B.A.; Van Langen, J.; Obrutsky, L.

    2006-01-01

    This paper presents an overview of the x-probe MB 350 eddy current inspection array probe, for detection of open OD axial crack-like flaws in Monel 400 tubes at Pickering Nuclear Generating Station. This report contains a selection of inspection results from the field inspections performed with this probe during the 2003 and 2004 period at Pickering Nuclear Generating Station A and B. During the 2003 in-service eddy current inspection results of Pickering Nuclear Generating Station A (PNGS-A) Unit 2, a 13 mm (0.5 inch) long axial indication was detected by the CTR1 bobbin and CTR2-C4 array probes in Tube R25-C52 of Steam Generator (SG) 11 in the hot leg sludge pile region. An experimental magnetic bias X-probe, specially designed by Zetec for inspection of Monel 400 tubing, was deployed and the indication was characterized as a potential out diameter (OD) axially oriented crack. Post-inspection tube pulling and destructive examination confirmed the presence of an Environmentally Assisted Crack (EAC), approximately 80% deep and 13mm long. Due to the significance of this discovery, Ontario Power Generation (OPG) requested AECL to initiate a program for qualification of the X-probe MB 350 for the detection of OD axial cracks in medium to high magnetic permeability μ r Monel 400 PNGS-A and B steam generator tubing at different locations. The X-probe MB 350 subsequently has been deployed as a primary inspection probe for crack detection for PNGS steam generators. (author)

  13. Role of lactobacillus cell surface hydrophobicity as probed by AFM in adhesion to surfaces at low and high ionic strength

    NARCIS (Netherlands)

    Vadillo Rodriguez, Virginia; Busscher, Hendrik; van der Mei, Henderina; Norde, Willem; de Vries, Jacob

    2005-01-01

    The S-layer present at the outermost cell surface of some lactobacillus species is known to convey hydrophobicity to the lactobacillus cell surface. Yet, it is commonly found that adhesion of lactobacilli to solid substrata does not proceed according to expectations based on cell surface

  14. Role of lactobacillus cell surface hydrophobicity as probed by AMF in adhesion to surfaces at low and high ionic strength

    NARCIS (Netherlands)

    Vadillo-Rodriguez, V.; Busscher, H.J.; Meij, van der H.C.; Vries, de J.; Norde, W.

    2005-01-01

    The S-layer present at the outermost cell surface of some lactobacillus species is known to convey hydrophobicity to the lactobacillus cell surface. Yet, it is commonly found that adhesion of lactobacilli to solid substrata does not proceed according to expectations based on cell surface

  15. A high excitation magnetic quadrupole lens quadruplet incorporating a single octupole lens for a low spherical aberration probe forming lens system

    Science.gov (United States)

    Dou, Yanxin; Jamieson, David N.; Liu, Jianli; Li, Liyi

    2018-03-01

    This paper describes the design of a new probe forming lens system consisting of a high excitation magnetic quadrupole lens quadruplet that incorporates a single magnetic octupole lens. This system achieves both a high demagnification and a low spherical aberration compared to conventional high excitation systems and is intended for deployment for the Harbin 300 MeV proton microprobe for applications in space science and ion beam therapy. This relative simplicity of the ion optical design to include a single octupole lens minimizes the risks associated with the constructional and operational precision usually needed for the probe forming lens system and this system could also be deployed in microprobe systems that operate with less magnetically rigid ions. The design of the new system is validated with reference to two independent ion optical computer codes.

  16. Watching ultrafast responses of structure and magnetism in condensed matter with momentum-resolved probes

    Directory of Open Access Journals (Sweden)

    S. L. Johnson

    2017-11-01

    Full Text Available We present a non-comprehensive review of some representative experimental studies in crystalline condensed matter systems where the effects of intense ultrashort light pulses are probed using x-ray diffraction and photoelectron spectroscopy. On an ultrafast (sub-picosecond time scale, conventional concepts derived from the assumption of thermodynamic equilibrium must often be modified in order to adequately describe the time-dependent changes in material properties. There are several commonly adopted approaches to this modification, appropriate in different experimental circumstances. One approach is to treat the material as a collection of quasi-thermal subsystems in thermal contact with each other in the so-called “N-temperature” models. On the other extreme, one can also treat the time-dependent changes as fully coherent dynamics of a sometimes complex network of excitations. Here, we present examples of experiments that fall into each of these categories, as well as experiments that partake of both models. We conclude with a discussion of the limitations and future potential of these concepts.

  17. Analytical Calculation of Magnetic Field Distribution and Stator Iron Losses for Surface-Mounted Permanent Magnet Synchronous Machines

    Directory of Open Access Journals (Sweden)

    Zhen Tian

    2017-03-01

    Full Text Available Permanent-magnet synchronous machines (PMSMs are widely used in electric vehicles owing to many advantages, such as high power density, high efficiency, etc. Iron losses can account for a significant component of the total loss in permanent-magnet (PM machines. Consequently, these losses should be carefully considered during the PMSM design. In this paper, an analytical calculation method has been proposed to predict the magnetic field distribution and stator iron losses in the surface-mounted permanent magnet (SPM synchronous machines. The method introduces the notion of complex relative air-gap permeance to take into account the effect of slotting. The imaginary part of the relative air-gap permeance is neglected to simplify the calculation of the magnetic field distribution in the slotted air gap for the surface-mounted permanent-magnet (SPM machine. Based on the armature reaction magnetic field analysis, the stator iron losses can be estimated by the modified Steinmetz equation. The stator iron losses under load conditions are calculated according to the varying d-q-axis currents of different control methods. In order to verify the analysis method, finite element simulation results are compared with analytical calculations. The comparisons show good performance of the proposed analytical method.

  18. Reciprocal space XRD mapping with varied incident angle as a probe of structure variation within surface depth

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Qiguang [Norfolk State University; Williams, Frances [Norfolk State University; Zhao, Xin [JLAB; Reece, Charles E. [JLAB; Krishnan, Mahadevan [AASC, San Leandro, California

    2013-09-01

    In this study, we used a differential-depth X-Ray diffraction Reciprocal Spacing Mapping (XRD RSM) technique to investigate the crystal quality of a variety of SRF-relevant Nb film and bulk materials. By choosing different X-ray probing depths, the RSM study successfully revealed evolution the of materials microstructure after different materials processes, such as energetic condensation or surface polishing. The RSM data clearly measured the materials crystal quality at different thickness. Through a novel differential-depth RSM technique, this study found: I. for a heteroepitaxy Nb film Nb(100)/MgO(100), the film thickening process, via a cathodic arc-discharge Nb ion deposition, created a near-perfect single crystal Nb on the surfaces top-layer; II. for a mechanically polished single-crystal bulk Nb material, the microstructure on the top surface layer is more disordered than that in-grain.

  19. The role of MFM signal in mark size measurement in probe-based magnetic recording on CoNi/Pt multilayers

    International Nuclear Information System (INIS)

    Zhang Li; Bain, James A.; Zhu Jiangang; Abelmann, Leon; Onoue, Takahiro

    2007-01-01

    A method of heat-assisted magnetic recording (HAMR) potentially suitable for probe-based storage systems is characterized. Magnetic marks were formed by a scanning tunneling microscopy (STM)-based thermal magnetic mechanism on a perpendicular CoNi/Pt multilayered film. Magnetic force microscopy (MFM) was applied to display those marks. The MFM signal is dependent of the lift-height during MFM scanning: smaller lift-height leads to higher resolution of the MFM image and a double-peak signal line, while higher lift-height leads to lower resolution and a single-peak signal line. Theoretical calculation of the magnetic field from the mark was executed. It agrees well with experiments, and demonstrates the method of mark size measurement in perpendicular media: full-width half-maximum (FWHM) of the measured MFM signal

  20. In situ real-time gravimetric and viscoelastic probing of surface films formation on lithium batteries electrodes.

    Science.gov (United States)

    Dargel, Vadim; Shpigel, Netanel; Sigalov, Sergey; Nayak, Prasant; Levi, Mikhael D; Daikhin, Leonid; Aurbach, Doron

    2017-11-09

    It is generally accepted that solid-electrolyte interphase formed on the surface of lithium-battery electrodes play a key role in controlling their cycling performance. Although a large variety of surface-sensitive spectroscopies and microscopies were used for their characterization, the focus was on surface species nature rather than on the mechanical properties of the surface films. Here we report a highly sensitive method of gravimetric and viscoelastic probing of the formation of surface films on composite Li 4 Ti 5 O 12 electrode coupled with lithium ions intercalation into this electrode. Electrochemical quartz-crystal microbalance with dissipation monitoring measurements were performed with LiTFSI, LiPF 6 , and LiPF 6  + 2% vinylene carbonate solutions from which structural parameters of the surface films were returned by fitting to a multilayer viscoelastic model. Only a few fast cycles are required to qualify surface films on Li 4 Ti 5 O 12 anode improving in the sequence LiPF 6  < LiPF 6  + 2% vinylene carbonate < LiTFSI.

  1. Order-disorder transitions in adsorbed systems on magnetic surfaces

    International Nuclear Information System (INIS)

    Aguilera-Granja, F.; Moran-Lopez, J.L.; Instituto Politecnico Nacional, Mexico City. Centro de Investigacion y de Estudios Avanzados); Falicov, L.M.

    1984-01-01

    It is investigated the effect of adsorbed atoms on the magnetic properties of ferromagnets. The Ising model is employed considering nearest neigbours with antiferromagnetic coupling between atoms. (M.W.O.) [pt

  2. Local Environment and Interactions of Liquid and Solid Interfaces Revealed by Spectral Line Shape of Surface Selective Nonlinear Vibrational Probe

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Shun-Li; Fu, Li; Chase, Zizwe A.; Gan, Wei; Wang, Hong-Fei

    2016-11-10

    Vibrational spectral lineshape contains important detailed information of molecular vibration and reports its specific interactions and couplings to its local environment. In this work, recently developed sub-1 cm-1 high-resolution broadband sum frequency generation vibrational spectroscopy (HR-BB-SFG-VS) was used to measure the -C≡N stretch vibration in the 4-n-octyl-4’-cyanobiphenyl (8CB) Langmuir or Langmuir-Blodgett (LB) monolayer as a unique vibrational probe, and the spectral lineshape analysis revealed the local environment and interactions at the air/water, air/glass, air/calcium fluoride and air/-quartz interfaces for the first time. The 8CB Langmuir or LB film is uniform and the vibrational spectral lineshape of its -C≡N group has been well characterized, making it a good choice as the surface vibrational probe. Lineshape analysis of the 8CB -C≡N stretch SFG vibrational spectra suggests the coherent vibrational dynamics and the structural and dynamic inhomogeneity of the -C≡N group at each interface are uniquely different. In addition, it is also found that there are significantly different roles for water molecules in the LB films on different substrate surfaces. These results demonstrated the novel capabilities of the surface nonlinear spectroscopy in characterization and in understanding the specific structures and chemical interactions at the liquid and solid interfaces in general.

  3. Detection of spring steel surface decarburization by magnetic hysteresis measurements

    Czech Academy of Sciences Publication Activity Database

    Perevertov, Oleksiy; Stupakov, Oleksandr; Tomáš, Ivan; Skrbek, B.

    2011-01-01

    Roč. 44, č. 6 (2011), s. 490-494 ISSN 0963-8695 R&D Projects: GA ČR GA101/09/1323; GA ČR GP102/09/P108 Grant - others:AV ČR(CZ) M100100906 Institutional research plan: CEZ:AV0Z10100520 Keywords : decarburization * magnetic hysteresis * spring steel Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.477, year: 2011

  4. Probing beer aging chemistry by nuclear magnetic resonance and multivariate analysis

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, J.A. [CICECO-Department of Chemistry, University of Aveiro, Campus de Santiago, 3810-193 Aveiro (Portugal); Barros, A.S. [QOPNA-Department of Chemistry, University of Aveiro, Campus de Santiago, 3810-193 Aveiro (Portugal); Carvalho, B.; Brandao, T. [UNICER, Bebidas de Portugal, Leca do Balio, 4466-955, S. Mamede de Infesta (Portugal); Gil, Ana M., E-mail: agil@ua.pt [CICECO-Department of Chemistry, University of Aveiro, Campus de Santiago, 3810-193 Aveiro (Portugal)

    2011-09-30

    Graphical abstract: The use of nuclear magnetic resonance (NMR) metabonomics for monitoring the chemical changes occurring in beer exposed to forced aging (at 45 deg. C for up to 18 days) is described. Both principal component analysis (PCA) and partial least squares-discriminant analysis (PLS-DA) were applied to the NMR spectra of beer recorded as a function of aging and an aging trend was observed. Inspection of PLS-DA loadings and peak integration revealed the importance of well known markers (e.g. 5-HMF) as well as of other compounds: amino acids, higher alcohols, organic acids, dextrins and some still unassigned spin systems. 2D correlation analysis enabled relevant compound variations to be confirmed and inter-compound correlations to be assessed, thus offering improved insight into the chemical aspects of beer aging. Highlights: {center_dot} Use of NMR metabonomics for monitoring the chemical changes occurring in beer exposed to forced aging. {center_dot} Compositional variations evaluated by principal component analysis and partial least squares-discriminant analysis. {center_dot} Results reveal importance of known markers and other compounds: amino and organic acids, higher alcohols, dextrins. {center_dot} 2D correlation analysis reveals inter-compound relationships, offering insight into beer aging chemistry. - Abstract: This paper describes the use of nuclear magnetic resonance (NMR) spectroscopy, in tandem with multivariate analysis (MVA), for monitoring the chemical changes occurring in a lager beer exposed to forced aging (at 45 deg. C for up to 18 days). To evaluate the resulting compositional variations, both principal component analysis (PCA) and partial least squares-discriminant analysis (PLS-DA) were applied to the NMR spectra of beer recorded as a function of aging and a clear aging trend was observed. Inspection of PLS-DA loadings and peak integration enabled the changing compounds to be identified, revealing the importance of well known

  5. Probing beer aging chemistry by nuclear magnetic resonance and multivariate analysis

    International Nuclear Information System (INIS)

    Rodrigues, J.A.; Barros, A.S.; Carvalho, B.; Brandao, T.; Gil, Ana M.

    2011-01-01

    Graphical abstract: The use of nuclear magnetic resonance (NMR) metabonomics for monitoring the chemical changes occurring in beer exposed to forced aging (at 45 deg. C for up to 18 days) is described. Both principal component analysis (PCA) and partial least squares-discriminant analysis (PLS-DA) were applied to the NMR spectra of beer recorded as a function of aging and an aging trend was observed. Inspection of PLS-DA loadings and peak integration revealed the importance of well known markers (e.g. 5-HMF) as well as of other compounds: amino acids, higher alcohols, organic acids, dextrins and some still unassigned spin systems. 2D correlation analysis enabled relevant compound variations to be confirmed and inter-compound correlations to be assessed, thus offering improved insight into the chemical aspects of beer aging. Highlights: · Use of NMR metabonomics for monitoring the chemical changes occurring in beer exposed to forced aging. · Compositional variations evaluated by principal component analysis and partial least squares-discriminant analysis. · Results reveal importance of known markers and other compounds: amino and organic acids, higher alcohols, dextrins. · 2D correlation analysis reveals inter-compound relationships, offering insight into beer aging chemistry. - Abstract: This paper describes the use of nuclear magnetic resonance (NMR) spectroscopy, in tandem with multivariate analysis (MVA), for monitoring the chemical changes occurring in a lager beer exposed to forced aging (at 45 deg. C for up to 18 days). To evaluate the resulting compositional variations, both principal component analysis (PCA) and partial least squares-discriminant analysis (PLS-DA) were applied to the NMR spectra of beer recorded as a function of aging and a clear aging trend was observed. Inspection of PLS-DA loadings and peak integration enabled the changing compounds to be identified, revealing the importance of well known markers such as 5-hydroxymethylfurfural (5

  6. Stability of skyrmions on curved surfaces in the presence of a magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho-Santos, V.L., E-mail: vagson.carvalho@usach.cl [Instituto Federal de Educação, Ciência e Tecnologia Baiano - Campus Senhor do Bonfim, Km 04 Estrada da Igara, 48970-000 Senhor do Bonfim, Bahia (Brazil); Departamento de Física, Universidad de Santiago de Chile and CEDENNA, Avda. Ecuador 3493, Santiago (Chile); Elias, R.G.; Altbir, D. [Departamento de Física, Universidad de Santiago de Chile and CEDENNA, Avda. Ecuador 3493, Santiago (Chile); Fonseca, J.M. [Universidade Federal de Viçosa, Departamento de Física, Avenida Peter Henry Rolfs s/n, 36570-000 Viçosa, MG (Brazil)

    2015-10-01

    We study the stability and energetics associated to skyrmions appearing as excitations on curved surfaces. Using a continuum model we show that the presence of cylindrically radial and azimuthal fields destabilize the skyrmions that appear in the absence of an external field. Weak fields generate fractional skyrmions while strong magnetic fields yield stable 2π-skyrmions, which have their widths diminished by the magnetic field strength. Under azimuthal fields vortex appears as stable state on the curved surface. - Highlights: • Stability of skyrmions on curved surfaces in the presence of a magnetic field. • Weak fields can destabilize skyrmions. • Strong magnetic fields yield the appearing of 2π-skyrmions. • The width of skyrmions is determined by the curvature and magnetic field strength. • Under azimuthal fields vortex appears as stable states.

  7. Probing droplets with biological colloidal suspensions on smart surfaces by synchrotron radiation micro- and nano-beams

    KAUST Repository

    Marinaro, Giovanni

    2015-03-01

    Droplets with colloidal biological suspensions evaporating on substrates with defined wetting properties generate confined environments for initiating aggregation and self-assembly processes. We describe smart micro- and nanostructured surfaces, optimized for probing single droplets and residues by synchrotron radiation micro- and nanobeam diffraction techniques. Applications are presented for Ac-IVD and β-amyloid (1-42) peptides capable of forming cross-β sheet structures. Complementary synchrotron radiation FTIR microspectroscopy addresses secondary structure formation. The high synchrotron radiation source brilliance enables fast raster-scan experiments. © 2015 Elsevier Ltd.

  8. HI observations of low surface brightness galaxies : Probing low-density galaxies

    NARCIS (Netherlands)

    deBlok, WJG; McGaugh, SS; vanderHulst, JM

    1996-01-01

    We present Very Large Array (VLA) and Westerbork Synthesis Radio Telescope (WSRT) 21-cm HI observations of 19 late-type low surface brightness (LSB) galaxies. Our main findings are that these galaxies, as well as having low surface brightnesses, have low HI surface densities, about a factor of

  9. X-ray free electron laser as a real-time probe of chemistry on surfaces

    International Nuclear Information System (INIS)

    Katayama, Tetsuo; Ogasawara, Hirohito

    2015-01-01

    X-ray free electron laser has opened up new possibilities for the study of surface chemical reactions on ultrafast time scale. This article reviews the recent work on the desorption of a molecule from a surface, which is one of the most fundamental surface chemical process. (author)

  10. Probing adsorption phenomena on a single crystal Pt-alloy surface under oxygen reduction reaction conditions

    DEFF Research Database (Denmark)

    Bondarenko, Alexander S.; Stephens, Ifan E.L.; Bech, Lone

    2012-01-01

    The adsorption dynamics of *OH and *O species at Pt(111) and Cu/Pt(111) near-surface alloy (NSA) surfaces in oxygen-free and O2-saturated 0.1M HClO4 was investigated. Subsurface Cu modifies the electronic structure at the Pt(111) surface resulting in weaker bonding to adsorbates like *OH, *H or *...

  11. Probing gender-specific metabolism differences in humans by nuclear magnetic resonance-based metabonomics.

    Science.gov (United States)

    Kochhar, Sunil; Jacobs, Doris M; Ramadan, Ziad; Berruex, France; Fuerholz, Andreas; Fay, Laurent B

    2006-05-15

    The measurement of metabolite profiles that are interpreted to yield biomarkers using multivariate data analysis is now a well-established approach for gaining an improved understanding of the impact of genetic modifications, toxicological and therapeutic interventions, and exposure to stimuli (e.g., noxious agents, stressors, nutrients) on the network of transcripts, proteins, and metabolites present in cells, tissues, or whole organisms. This has been termed metabonomics. In this study, multivariate analysis of (1)H nuclear magnetic resonance (NMR) spectra of metabolite profiles of urine and plasma from 150 healthy humans revealed that in young people and/or individuals with low body mass indexes, females had higher rates of lipid biosynthesis than did males, whereas males had higher rates of protein turnover than did females. With increasing age, overall lipid biosynthesis decreased in females, whereas metabolism increasingly favored lipid synthesis over protein turnover in males. By relating the derived metabonomic data to known metabolic pathways and published biochemical data, it appears that females synthesize relatively more lipoproteins and unsaturated lipids than do males. Furthermore, the changes in lipid biosynthesis and urinary citrate excretion in females showed a positive correlation. Estrogen most likely plays an essential role in the regulation of, and communication between, protein and lipid biosynthesis by controlling pH in mitochondria and the cytoplasm and hence the observed altered citrate levels.

  12. Long wave dispersion relations for surface waves in a magnetically structured atmosphere

    International Nuclear Information System (INIS)

    Rae, I.C.; Roberts, B.

    1983-01-01

    A means of obtaining approximate dispersion relations for long wavelength magnetoacoustic surface waves propagating in a magnetically structured atmosphere is presented. A general dispersion relation applying to a wide range of magnetic profiles is obtained, and illustrated for the special cases of a single interface and a magnetic slab. In the slab geometry, for example, the dispersion relation contains both the even (sausage) and odd (kink) modes in one formalism

  13. Direct Observation of Domain-Wall Surface Tension by Deflating or Inflating a Magnetic Bubble

    Science.gov (United States)

    Zhang, Xueying; Vernier, Nicolas; Zhao, Weisheng; Yu, Haiming; Vila, Laurent; Zhang, Yue; Ravelosona, Dafiné

    2018-02-01

    The surface energy of a magnetic domain wall (DW) strongly affects its static and dynamic behaviors. However, this effect is seldom directly observed, and some of the related phenomena are not well understood. Moreover, a reliable method to quantify the DW surface energy is still absent. Here, we report a series of experiments in which the DW surface energy becomes a dominant parameter. We observe that a semicircular magnetic domain bubble can spontaneously collapse under the Laplace pressure induced by DW surface energy. We further demonstrate that the surface energy can lead to a geometrically induced pinning when the DW propagates in a Hall cross or from a nanowire into a nucleation pad. Based on these observations, we develop two methods to quantify the DW surface energy, which can be very helpful in the estimation of intrinsic parameters such as Dzyaloshinskii-Moriya interactions or exchange stiffness in magnetic ultrathin films.

  14. Magnetic scattering experiments

    International Nuclear Information System (INIS)

    Vettier, C.

    2001-01-01

    We discuss the relative use of neutrons and X-rays as scattering tools to probe the magnetic properties of materials. Neutron diffraction experiments continue to be the most appropriate tool to determine the magnetic structure of bulk solids. Synchrotron X-ray experiments are and will be used to investigate selectively the magnetic behaviour of different chemical species and/or electronic shells in magnetic systems. There exist some grey areas where the two probes can be used depending on the scientific problem under investigation. In particular, neutrons allow very accurate measurements of magnetic form factors, but X-rays provide a separation of the orbital momentum contribution to magnetisation. Comparisons between X-rays and neutrons studies of magnetism at surfaces are presented. Finally, one can anticipate that only inelastic neutron scattering experiments will allow the observation of magnetic excitations across the whole Brillouin zone

  15. In situ probing of surface hydrides on hydrogenated amorphous silicon using attenuated total reflection infrared spectroscopy

    CERN Document Server

    Kessels, W M M; Sanden, M C M; Aydil, E S

    2002-01-01

    An in situ method based on attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) is presented for detecting surface silicon hydrides on plasma deposited hydrogenated amorphous silicon (a-Si:H) films and for determining their surface concentrations. Surface silicon hydrides are desorbed by exposing the a-Si:H films to low energy ions from a low density Ar plasma and by comparing the infrared spectrum before and after this low energy ion bombardment, the absorptions by surface hydrides can sensitively be separated from absorptions by bulk hydrides incorporated into the film. An experimental comparison with other methods that utilize isotope exchange of the surface hydrogen with deuterium showed good agreement and the advantages and disadvantages of the different methods are discussed. Furthermore, the determination of the composition of the surface hydrogen bondings on the basis of the literature data on hydrogenated crystalline silicon surfaces is presented, and quantification of the h...

  16. Controllable magnetic doping of the surface state of a topological insulator

    DEFF Research Database (Denmark)

    Schlenk, T.; Bianchi, M.; Koleini, Mohammad

    2013-01-01

    principles calculations within density functional theory, these Fe substitutional impurities retain a large magnetic moment thus presenting an alternative scheme for magnetically doping the topological surface state. For both types of Fe doping, we see no indication of a gap at the Dirac point....

  17. Surface field in an ensemble of superconducting spheres under external magnetic field

    CERN Document Server

    Peñaranda, A; Ramírez-Piscina, L

    1999-01-01

    We perform calculations of the magnetic field on the surface of an ensemble of superconducting spheres when placed into an external magnetic field, which is the configuration employed in superheated superconducting granule detectors. The Laplace equation is numerically solved with appropriate boundary conditions by means of an iterative procedure and a multipole expansion.

  18. Magnetic surface breaking in 3D MHD equilibria of 1=2 Heliotron

    International Nuclear Information System (INIS)

    Hayashi, Takaya; Takei, Akira; Sato, Tetsuya.

    1992-01-01

    Magnetic surface breaking due to the finite pressure effect is analyzed for three dimensional magnetohydrodynamic equilibria of 1=2 Heliotron configuration. Characteristics of magnetic island formation are extensively surveyed. It is found that the well-hill criterion which has been predicted by the local analysis is not always applicable for all cases. (author)

  19. Estimating Antarctic near-surface magnetic anomalies from Oersted and CHAMP satellite magnetometer observations

    Science.gov (United States)

    von Frese, R. R.; Kim, H.; Gaya-Pique, L. R.; Taylor, P. T.; Golynsky, A. V.; Kim, J.

    2004-12-01

    Significant improvement in predicting near-surface magnetic anomalies can result from the highly accurate magnetic observations of the CHAMP satellite that is orbiting at about 400 km altitude. In general, regional magnetic signals of the crust are strongly masked by the core field and its secular variations due to wavelength coupling in the spherical harmonic representation and thus are difficult to isolate in the satellite measurements. However, efforts to isolate the regional lithospheric from core field components can exploit the correlations between the CHAMP magnetic anomalies and the pseudo magnetic effects inferred from gravity-derived crustal thickness variations. In addition, we can use spectral correlation theory to filter the static lithospheric field components from the dynamic external field effects. Employing these procedures, we processed the CHAMP magnetic observations for an improved magnetic anomaly map of the Antarctic crust. Relative to the much higher altitude Oersted and noisier Magsat observations, CHAMP magnetic anomalies at 400 km altitude reveal new details on the effects of intra-crustal magnetic features and crustal thickness variations of the Antarctic. Moreover, these results greatly facilitate predicting magnetic anomalies in the regional coverage gaps of the ADMAP compilation of Antarctic magnetic anomalies from shipborne, airborne and ground surveys. Our analysis suggests that considerable new insights on the magnetic properties of the lithosphere may be revealed by a further order-of-magnitude improvement in the accuracy of the magnetometer measurements at minimum orbital altitude.

  20. Pair-breaking effects by parallel magnetic field in electric-field-induced surface superconductivity

    Energy Technology Data Exchange (ETDEWEB)

    Nabeta, Masahiro, E-mail: nabeta@mp.okayama-u.ac.jp; Tanaka, Kenta K.; Onari, Seiichiro; Ichioka, Masanori

    2016-11-15

    Highlights: • Zeeman effect shifts superconducting gaps of sub-band system, towards pair-breaking. • Higher-level sub-bands become normal-state-like electronic states by magnetic fields. • Magnetic field dependence of zero-energy DOS reflects multi-gap superconductivity. - Abstract: We study paramagnetic pair-breaking in electric-field-induced surface superconductivity, when magnetic field is applied parallel to the surface. The calculation is performed by Bogoliubov-de Gennes theory with s-wave pairing, including the screening effect of electric fields by the induced carriers near the surface. Due to the Zeeman shift by applied fields, electronic states at higher-level sub-bands become normal-state-like. Therefore, the magnetic field dependence of Fermi-energy density of states reflects the multi-gap structure in the surface superconductivity.

  1. Pair-breaking effects by parallel magnetic field in electric-field-induced surface superconductivity

    International Nuclear Information System (INIS)

    Nabeta, Masahiro; Tanaka, Kenta K.; Onari, Seiichiro; Ichioka, Masanori

    2016-01-01

    Highlights: • Zeeman effect shifts superconducting gaps of sub-band system, towards pair-breaking. • Higher-level sub-bands become normal-state-like electronic states by magnetic fields. • Magnetic field dependence of zero-energy DOS reflects multi-gap superconductivity. - Abstract: We study paramagnetic pair-breaking in electric-field-induced surface superconductivity, when magnetic field is applied parallel to the surface. The calculation is performed by Bogoliubov-de Gennes theory with s-wave pairing, including the screening effect of electric fields by the induced carriers near the surface. Due to the Zeeman shift by applied fields, electronic states at higher-level sub-bands become normal-state-like. Therefore, the magnetic field dependence of Fermi-energy density of states reflects the multi-gap structure in the surface superconductivity.

  2. Electroconvulsive therapy in the treatment of neuropsychiatric conditions and transcranial magnetic stimulation as a pathophysiological probe in neuropsychiatry.

    Science.gov (United States)

    McDonald, W M; Greenberg, B D

    2000-01-01

    It is a challenging task to review transcranial magnetic stimulation (TMS) studies in neuropsychiatric disorders alongside assessments of longstanding clinical applications of ECT as an empirical treatment. The task is challenging because TMS was developed as a probe of neural mechanisms, whereas, in marked contrast, ECT has been a clinical technique from its inception. Since the onset of modern psychopharmacology, the understanding of the potential applications of ECT to neuropsychiatric disorders is generally restricted to case reports of patients with intractable disease that have had at least a partial response to ECT. Studies of the possible efficacy of TMS in neuropsychiatric conditions have a significant advantage over ECT as the treatments are associated with less morbidity. The only serious known complication in TMS is a risk of seizures that may increase in patients with neuropsychiatric conditions such as course brain disease. Only cortical structures are themselves accessible to TMS using current technology. Present TMS techniques, however, seem capable of affecting activity in deeper brain structures that are functionally linked to cortical brain regions. TMS permits novel explorations of relationships between regional brain activity and symptoms of a number of neuropsychiatric disorders, as well as in research relating activity in functionally related brain regions to modulation of cognition and affective states in healthy individuals. This is particularly true at present because TMS and powerful neuroimaging and neuropsychological tools are all making rapid advances simultaneously.

  3. Hyperfine field distribution in the Heusler compound Co2FeAl probed by 59Co nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Wurmehl, Sabine; Kohlhepp, Juergen T; Swagten, Henk J M; Koopmans, Bert

    2008-01-01

    The Heusler compound Co 2 FeAl is reported to occur in various structures ranging from the completely ordered L2 1 to the completely disordered A2 structure type. In this work, we use spin echo nuclear magnetic resonance (NMR) to probe the local structure of Co 2 FeAl bulk samples. The study of Co 2 FeAl bulk samples provides the unique possibility to verify the intrinsic generic structural properties. The 59 Co NMR measurements reveal a distribution of Fe and Al not only in the first neighbouring shells of the 59 Co nuclei but also in more distant shells. The analysis of 59 Co NMR main resonance lines with an underlying sub-structure confirms that the local structure of the as-cast Co 2 FeAl bulk samples consists of a B2 type structure with contributions of the L2 1 type structure of about 10%. The observed sub-lines, which are attributed to a distribution of Fe and Al atoms in more distant shells, were previously not resolved in NMR spectra of Co 2 FeAl thin films, pointing to better long range order in bulk material than in thin films. We also show that the individual contributions of the structure types can be influenced by annealing

  4. An ultra-low temperature scanning Hall probe microscope for magnetic imaging below 40 mK

    Science.gov (United States)

    Karcı, Özgür; Piatek, Julian O.; Jorba, Pau; Dede, Münir; Rønnow, Henrik M.; Oral, Ahmet

    2014-10-01

    We describe the design of a low temperature scanning Hall probe microscope (SHPM) for a dilution refrigerator system. A detachable SHPM head with 25.4 mm OD and 200 mm length is integrated at the end of the mixing chamber base plate of the dilution refrigerator insert (Oxford Instruments, Kelvinox MX-400) by means of a dedicated docking station. It is also possible to use this detachable SHPM head with a variable temperature insert (VTI) for 2 K-300 K operations. A microfabricated 1μm size Hall sensor (GaAs/AlGaAs) with integrated scanning tunneling microscopy tip was used for magnetic imaging. The field sensitivity of the Hall sensor was better than 1 mG/√Hz at 1 kHz bandwidth at 4 K. Both the domain structure and topography of LiHoF4, which is a transverse-field Ising model ferromagnet which orders below TC = 1.53 K, were imaged simultaneously below 40 mK.

  5. Van Allen Probes observations of unusually low frequency whistler mode waves observed in association with moderate magnetic storms: Statistical study.

    Science.gov (United States)

    Cattell, C A; Breneman, A W; Thaller, S A; Wygant, J R; Kletzing, C A; Kurth, W S

    2015-09-28

    We show the first evidence for locally excited chorus at frequencies below 0.1  f ce (electron cyclotron frequency) in the outer radiation belt. A statistical study of chorus during geomagnetic storms observed by the Van Allen Probes found that frequencies are often dramatically lower than expected. The frequency at peak power suddenly stops tracking the equatorial 0.5  f ce and f / f ce decreases rapidly, often to frequencies well below 0.1  f ce (in situ and mapped to equator). These very low frequency waves are observed both when the satellites are close to the equatorial plane and at higher magnetic latitudes. Poynting flux is consistent with generation at the equator. Wave amplitudes can be up to 20 to 40 mV/m and 2 to 4 nT. We conclude that conditions during moderate to large storms can excite unusually low frequency chorus, which is resonant with more energetic electrons than typical chorus, with critical implications for understanding radiation belt evolution.

  6. Paper-based magnetic nanoparticle-peptide probe for rapid and quantitative colorimetric detection of Escherichia coli O157:H7.

    Science.gov (United States)

    Suaifan, Ghadeer A R Y; Alhogail, Sahar; Zourob, Mohammed

    2017-06-15

    There is a critical and urgent demand for a simple, rapid and specific qualitative and quantitative colorimetric biosensor for the detection of the food contaminant Escherichia coli O157:H7 (E. coli O157:H7) in complex food products due to the recent outbreaks of food-borne diseases. Traditional detection techniques are time-consuming, require expensive instrumentation and are labour-intensive. To overcome these limitations, a novel, ultra-rapid visual biosensor was developed based on the ability of E. coli O157:H7 proteases to change the optical response of a surface-modified, magnetic nanoparticle-specific (MNP-specific) peptide probe. Upon proteolysis, a gradual increase in the golden color of the sensor surface was visually observed. The intensification of color was correlated with the E. coli O157:H7 concentration. The color change resulting from the dissociation of the self-assembled monolayer (SAM) was detected by the naked eye and analysed using an image analysis software (ImageJ) for the purpose of quantitative detection. This biosensor demonstrated high sensitivity and applicability, with lower limits of detection of 12CFUmL -1 in broth samples and 30-300CFUmL -1 in spiked complex food matrices. In conclusion, this approach permits the use of a disposable biosensor chip that can be mass-produced at low cost and can be used not only by food manufacturers but also by regulatory agencies for better control of potential health risks associated with the consumption of contaminated foods. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Pair-breaking effects by parallel magnetic field in electric-field-induced surface superconductivity

    Science.gov (United States)

    Nabeta, Masahiro; Tanaka, Kenta K.; Onari, Seiichiro; Ichioka, Masanori

    2016-11-01

    We study paramagnetic pair-breaking in electric-field-induced surface superconductivity, when magnetic field is applied parallel to the surface. The calculation is performed by Bogoliubov-de Gennes theory with s-wave pairing, including the screening effect of electric fields by the induced carriers near the surface. Due to the Zeeman shift by applied fields, electronic states at higher-level sub-bands become normal-state-like. Therefore, the magnetic field dependence of Fermi-energy density of states reflects the multi-gap structure in the surface superconductivity.

  8. Magnetic character of holmium atom adsorbed on platinum surface

    Czech Academy of Sciences Publication Activity Database

    Shick, Alexander; Shapiro, D.S.; Kolorenč, Jindřich; Lichtenstein, A.I.

    2017-01-01

    Roč. 7, č. 1 (2017), s. 1-6, č. článku 2751. ISSN 2045-2322 R&D Projects: GA ČR GC15-05872J Grant - others:GA MŠk(CZ) LM2015042 Institutional support: RVO:68378271 Keywords : rare-earth adatoms * density-functional theory * single- atom magnets Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) Impact factor: 4.259, year: 2016

  9. Anomalous magnetism of the nanocrystalline oxide TiO2 surface

    Science.gov (United States)

    Ermakov, A. E.; Uimin, M. A.; Korolev, A. V.; Volegov, A. S.; Byzov, I. V.; Shchegoleva, N. N.; Minin, A. S.

    2017-03-01

    The magnetic properties of an oxygen-deficient nanocrystalline undoped titanium dioxide synthesized by the gas-phase, electric-explosion, and chemical method have been studied. The defect state was controlled using reduction treatments in vacuum or in a hydrogen atmosphere. It is shown that the defect state of the surface of nanocrystalline oxides (for example, the existence of vacancies in the anion sublattice and other defects) has a dominant influence on the formation of the magnetic properties of the samples under study. The main contributions to the magnetism of TiO2 nanoparticles after the reduction treatments are the paramagnetic contribution of the matrix, the paramagnetic Curie-Weiss contribution, and the contribution of the spontaneous magnetic moment provided by the existence of regions with different spin ordering. A heterogeneous magnetic state is found to exist in the TiO2 nanopowders; for example, at low temperatures, shifted hysteresis loops are observed as a result of a possible set of magnetic states with different spin orders. It is shown that a soft compaction or grinding of nanopowders in an agate mortar lead to substantial increase in the magnetization, sometimes, by a factor of more than two, regardless of the nanopowder synthesis method and the initial phase state of TiO2 (anatase or rutile structures). This experimental fact proves the key role of the surface defects and the magnetic moment carriers with different spin configurations localized mainly on the nanoparticle surface. The compaction changes the magnetization only in the case when the initial magnetic state has a nonlinear "quasi-superparamagnetic" character of the magnetization curve. As a result of predominant exchange interaction between the nanoparticles with a frustrated character of spin ordering on the nanoparticles surface, the ferromagnetic contribution increases as nanoparticles contact.

  10. A Brief Note on the Magnetowetting of Magnetic Nanofluids on AAO Surfaces

    Directory of Open Access Journals (Sweden)

    Yu-Chin Chien

    2018-02-01

    Full Text Available In magnetowetting, the material properties of liquid, surface morphology of solid, and applied external field are three major factors used to determine the wettability of a liquid droplet on a surface. For wetting measurements, an irregular or uneven surface could result in a significant experimental uncertainty. The periodic array with a hexagonal symmetry structure is an advantage of the anodic aluminum oxide (AAO structure. This study presents the results of the wetting properties of magnetic nanofluid sessile droplets on surfaces of various AAO pore sizes under an applied external magnetic field. Stable, water-based magnetite nanofluids are prepared by combining the chemical co-precipitation with the sol-gel technique, and AAO surfaces are then generated by anodizing the aluminum sheet in the beginning. The influence of pore size and magnetic field gradient on the magnetowetting of magnetic nanofluids on AAO surfaces is then investigated by an optical test system. Experimental results show that increasing the processing voltage of AAO templates could result in enhanced non-wettability behavior; that is, the increase in AAO pore size could lead to the increase in contact angle. The contact angle could be reduced by the applied magnetic field gradient. In general, the magnetic field has a more significant effect at smaller AAO pore sizes.

  11. Monte Carlo simulation of the surface magnetic phase transition in chromium

    International Nuclear Information System (INIS)

    Mata, G.J.; Valera, M.

    1995-03-01

    Antiferromagnetic chromium is known to have a surface magnetic phase transition at a temperature T s = 780K, which is well above its bulk Neel temperature, T N = 311K. Electronic structure calculations predict an enhancement of the magnetic moment at the surface, due to changes in the local electronic environment. In order to ascertain the role of such an enhancement in the surface magnetic transition, we have modelled the surface by means of a classical Heisenberg model in which: a) the magnitude of a given spin is equal to the value of the corresponding magnetic moment predicted by band structure calculations, b) the exchange interaction J between spins is the same throughout the system, and c) the exchange interaction is chosen so as to reproduce the bulk transition temperature. We find a ratio of surface to bulk transition temperature of T S /T N = 2.5, which is an excellent agreement with the experimental result. Our results suggest that the surface magnetic transition in chromium is driven by fluctuations in the orientation of the magnetic moments and that quantum fluctuations play a minor role. (author). 18 refs, 5 figs

  12. Probing the intrinsically oil-wet surfaces of pores in North Sea chalk at subpore resolution

    DEFF Research Database (Denmark)

    Hassenkam, Tue; Skovbjerg, Lone Lindbæk; Stipp, Susan Louise Svane

    2009-01-01

    Ultimate Oil recovery from chalk reservoirs is limited by many factors - including the grain size and the surface properties of the small mainly biogenic calcite particles that chalk is made off . Wettability, the tendency for water or oil to spread over a surface, of the particle surfaces is one......, not a product of later migration of oil into the reservoir, which is known to alter the wettability of the surfaces. The data indicated distinct patches, with diameters ranging from 500 to 50 nm, which appears to have different wettability The size of the patches is significantly less than the size of the chalk...

  13. Atom probe study on microstructure change in severely deformed pearlitic steels: application to rail surfaces and drawn wires

    Science.gov (United States)

    Takahashi, Jun

    2017-07-01

    Pearlitic steel is used as the material for high tensile steel wires, rails and wheels due to its high work hardening and wear resistance. These properties arise from a layered structure comprising deformable lamellar ferrite and hard lamellar cementite. This paper reviews the microstructural change in heavily drawn pearlitic steels wires and worn surfaces of pearlitic rails using atom probe tomography analysis. The cementite decomposition mechanism was elucidated for heavily drawn pearlitic steel wires. For pearlitic rail steels, atomic scale characterization of worn surfaces and of the white etching layer (WEL) were performed, and a mechanism for the formation of the WEL was proposed. The differences and similarities in microstructure and in the state of the cementite in these severely deformed pearlitic steels are discussed.

  14. Device for positioning ultrasonic probes and/or television cameras on the outer surface of reactor pressure vessels

    International Nuclear Information System (INIS)

    Zipser, R.; Dose, G.F.

    1977-01-01

    The device makes possible periodical in-service inspections of welding seams and material of a reactor pressure vessel without local human presence. A 'support ring' encloses the pressure vessel in a horizontal plane with free space. It is vertically moved up and down in the space between pressure vessel and thermal shield by means of tackles. At a control desk placed in a protected area its movement is controlled and its vertical position is indicated. A 'rotating track' with its own drive is rotating remote-controlled on the 'support ring'. By a combination of the vertical with the rotating movement, an ultrasonic probe placed removably on the 'rotating hack', or a television camera will be brought to any position on the cylindrical circumference of the pressure vessel. Special devices extend the radius of action, in upward direction for inspecting the welding seams of the coolant nozzles, and in downward direction for the inspection of welds on the hemispherical bottom of the pressure vessel or on the outlet pipe nozzle placed there. The device remains installed during reactor operation, but is moved down to the lower horizontal surface of the thermal shield. Parts which are sensible to radiation like probes or television cameras and special devices will then be removed respectively mounted before beginning an inspection compaign. This position may be reached by the lower access in the biological shield and through an opening in the horizontal surface of the thermal shield. (HP) [de

  15. Surface and Downhole Prospecting Tools for Planetary Exploration: Tests of Neutron and Gamma Ray Probes - Research Paper

    Energy Technology Data Exchange (ETDEWEB)

    R. C. Elphic; P. Chu; S. Hahn; M. R. James; D. J. Lawrence; T. H. Prettyman; J. B. Johnson; R. K. Podgorney

    2008-06-01

    The ability to locate and characterize icy deposits and other hydrogenous materials on the Moon and Mars will help us understand the distribution of water and, therefore, possible habitats at Mars, and may help us locate primitive prebiotic compounds at the Moon’s poles. We have developed a rover-borne neutron probe that localizes a near-surface icy deposit and provides information about its burial depth and abundance. We have also developed a borehole neutron probe to determine the stratigraphy of hydrogenous subsurface layers while operating within a drill string segment. In our field tests, we have used a neutron source to “illuminate” surrounding materials and gauge the instruments’ efficacy, and we can simulate accurately the observed instrument responses using a Monte Carlo nuclear transport code (MCNPX). An active neutron source would not be needed for lunar or martian near-surface exploration: cosmic-ray interactions provide sufficient neutron flux to depths of several meters and yield better depth and abundance sensitivity than an active source. However, for deep drilling (>10 m depth), a source is required. We also present initial tests of a borehole gamma ray lithodensity tool and demonstrate its utility in determining soil or rock densities and composition.

  16. Dynamics of phenanthrenequinone on carbon nano-onion surfaces probed by quasielastic neutron scattering.

    Science.gov (United States)

    Chathoth, Suresh M; Anjos, Daniela M; Mamontov, Eugene; Brown, Gilbert M; Overbury, Steven H

    2012-06-21

    We used quasielastic neutron scattering (QENS) to study the dynamics of phenanthrenequinone (PQ) on the surface of onion-like carbon (OLC), or so-called carbon onions, as a function of surface coverage and temperature. For both the high- and low-coverage samples, we observed two diffusion processes; a faster process and nearly an order of magnitude slower process. On the high-coverage surface, the slow diffusion process is of long-range translational character, whereas the fast diffusion process is spatially localized on the length scale of ∼4.7 Å. On the low-coverage surface, both diffusion processes are spatially localized; on the same length scale of ∼4.7 Å for the fast diffusion and a somewhat larger length scale for the slow diffusion. Arrhenius temperature dependence is observed except for the long-range diffusion on the high-coverage surface. We attribute the fast diffusion process to the generic localized in-cage dynamics of PQ molecules, and the slow diffusion process to the long-range translational dynamics of PQ molecules, which, depending on the coverage, may be either spatially restricted or long-range. On the low-coverage surface, uniform surface coverage is not attained, and the PQ molecules experience the effect of spatial constraints on their long-range translational dynamics. Unexpectedly, the dynamics of PQ molecules on OLC as a function of temperature and surface coverage bears qualitative resemblance to the dynamics of water molecules on oxide surfaces, including practically temperature-independent residence times for the low-coverage surface. The dynamics features that we observed may be universal across different classes of surface adsorbates.

  17. Dynamics of Phenanthrenequinone on Carbon Nano-Onion Surfaces Probed by Quasielastic Neutron Scattering

    International Nuclear Information System (INIS)

    Mamontov, Eugene; Brown, Gilbert M.; Overbury, Steven H.; Mavila Chathoth, Suresh

    2012-01-01

    We used quasielastic neutron scattering (QENS) to study the dynamics of phenanthrenequinone (PQ) on the surface of onion-like carbon (OLC), or so called carbon onions, as a function of surface coverage and temperature. For both the high- and low-coverage samples, we observed two diffusion processes; a faster process and nearly an order of magnitude slower process. On the high-coverage surface, the slow diffusion process is of long-range translational character, whereas the fast diffusion process is spatially localized on the length scale of ∼ 4.7. On the low-coverage surface, both diffusion processes are spatially localized; on the same length scale of ∼ 4.7 for the fast diffusion and a somewhat larger length scale for the slow diffusion. Arrhenius temperature dependence is observed except for the long-range diffusion on the high-coverage surface. We attribute the fast diffusion process to the generic localized in-cage dynamics of PQ molecules, and the slow diffusion process to the long-range translational dynamics of PQ molecules, which, depending on the coverage, may be either spatially restricted, or long-range. On the low-coverage surface, uniform surface coverage is not attained, and the PQ molecules experience the effect of spatial constraints on their long-range translational dynamics. Unexpectedly, the dynamics of PQ molecules on OLC as a function of temperature and surface coverage bears qualitative resemblance to the dynamics of water molecules on oxide surfaces, including practically temperature-independent residence times for the low-coverage surface. The dynamics features that we observed may be universal across different classes of surface adsorbates.

  18. Water adsorption on TiO2 surfaces probed by soft X-ray spectroscopies: bulk materials vs. isolated nanoparticles

    Science.gov (United States)

    Benkoula, Safia; Sublemontier, Olivier; Patanen, Minna; Nicolas, Christophe; Sirotti, Fausto; Naitabdi, Ahmed; Gaie-Levrel, François; Antonsson, Egill; Aureau, Damien; Ouf, François-Xavier; Wada, Shin-Ichi; Etcheberry, Arnaud; Ueda, Kiyoshi; Miron, Catalin

    2015-01-01

    We describe an experimental method to probe the adsorption of water at the surface of isolated, substrate-free TiO2 nanoparticles (NPs) based on soft X-ray spectroscopy in the gas phase using synchrotron radiation. To understand the interfacial properties between water and TiO2 surface, a water shell was adsorbed at the surface of TiO2 NPs. We used two different ways to control the hydration level of the NPs: in the first scheme, initially solvated NPs were dried and in the second one, dry NPs generated thanks to a commercial aerosol generator were exposed to water vapor. XPS was used to identify the signature of the water layer shell on the surface of the free TiO2 NPs and made it possible to follow the evolution of their hydration state. The results obtained allow the establishment of a qualitative determination of isolated NPs’ surface states, as well as to unravel water adsorption mechanisms. This method appears to be a unique approach to investigate the interface between an isolated nano-object and a solvent over-layer, paving the way towards new investigation methods in heterogeneous catalysis on nanomaterials. PMID:26462615

  19. Investigation of simultaneously existed Raman scattering enhancement and inhibiting fluorescence using surface modified gold nanostars as SERS probes.

    Science.gov (United States)

    Shan, Feng; Zhang, Xiao-Yang; Fu, Xing-Chang; Zhang, Li-Jiang; Su, Dan; Wang, Shan-Jiang; Wu, Jing-Yuan; Zhang, Tong

    2017-07-28

    One of the main challenges for highly sensitive surface-enhanced Raman scattering (SERS) detection is the noise interference of fluorescence signals arising from the analyte molecules. Here we used three types of gold nanostars (GNSs) SERS probes treated by different surface modification methods to reveal the simultaneously existed Raman scattering enhancement and inhibiting fluorescence behaviors during the SERS detection process. As the distance between the metal nanostructures and the analyte molecules can be well controlled by these three surface modification methods, we demonstrated that the fluorescence signals can be either quenched or enhanced during the detection. We found that fluorescence quenching will occur when analyte molecules are closely contacted to the surface of GNSs, leading to a ~100 fold enhancement of the SERS sensitivity. An optimized Raman signal detection limit, as low as the level of 10 -11  M, were achieved when Rhodamine 6 G were used as the analyte. The presented fluorescence-free GNSs SERS substrates with plentiful hot spots and controllable surface plasmon resonance wavelengths, fabricated using a cost-effective self-assembling method, can be very competitive candidates for high-sensitive SERS applications.

  20. An improved thin-layer chromatography/mass spectrometry coupling using a surface sampling probe electrospray ion trap system

    Energy Technology Data Exchange (ETDEWEB)

    Ford, Michael J [ORNL; Van Berkel, Gary J [ORNL

    2004-01-01

    A combined surface sampling probe/electrospray emitter coupled with an ion trap mass spectrometer was used for the direct read out of unmodified reversed-phase C18 thin-layer chromatography (TLC) plates. The operation of the surface sampling electrospray ionization interface in positive and negative ionization modes was demonstrated through the direct analysis of TLC plates on which a commercial test mix comprised of four dye compounds viz., rhodamine B, fluorescein, naphthol blue black, and fast green FCF, and an extract of the caffeine-containing plant Ilex vomitoria, were spotted and developed. Acquisition of full-scan mass spectra and automated collection of MS/MS product ion spectra while scanning a development lane along the surface of a TLC plate demonstrated the advantages of using an ion trap in this combination. Details of the sampling system, benefits of analyzing a developed lane in both positive ion and negative ion modes, levels of detection while surface scanning, surface scan speed effects, and the utility of three-dimensional data display, are also discussed.