WorldWideScience

Sample records for surface laboratory system

  1. Laboratory Determination of Thermal Protection System Materials Surface Catalytic Properties

    Science.gov (United States)

    2007-07-01

    Zalar, A., "Recombination of Neutral Hydrogen Atoms on AISI 304 Stainless Steel Surface," Applied Surface Science, Vol. 144-145, 1999, pp. 399-403. 57...and test environments. Typically, these fits contain only the temperature dependence of the loss probability, with no information on pressure or...generated in the MESOX test facility in the PROMES-CNRS laboratory on a variety of ceramic materials.47-50 The MESOX facility uses a flow tube

  2. Earth System Research Laboratory Long-Term Surface Aerosol Measurements

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Aerosol measurements began at the NOAA Earth System Research Laboratory (ESRL) Global Monitoring Division (GMD) baseline observatories in the mid-1970's with the...

  3. Hydrodynamic systems for assessing surface fouling, soil adherence and cleaning in laboratory installations

    Directory of Open Access Journals (Sweden)

    Detry JG.

    2009-01-01

    Full Text Available Five hydrodynamic systems are presented in this short review: the parallel plate flow cell, the impinging jet, the radial flow cell, the rotating disk and fluid dynamic gauging. These systems are of particular relevance to study surface fouling, surface cleaning or adhesion onto solid surfaces in laboratory environment. The key features of their hydrodynamics are given as well as their practical advantages and drawbacks. Examples of applications fields are also listed.

  4. Simulating the Near-Surface Environments of Solar System Bodies in the Laboratory

    Science.gov (United States)

    Donaldson Hanna, K. L.; Bowles, N. E.; Greenhagen, B. T.

    2016-12-01

    Thermal infrared (TIR) emissivity measurements are sensitive to a planetary body's near-surface (upper hundreds of microns) environment, porosity and particle size, which make the interpretation of thermal infrared remote sensing observations of planetary surfaces challenging. Thus, well-constrained laboratory TIR measurements of analogue samples for a range of particle sizes, porosities and near-surface environments are needed. Near-surface environments and porosities for a range of solar system bodies can be simulated using facilities within University of Oxford's Planetary Spectroscopy Facility (PSF). The Simulated Lunar Environment Chamber (SLEC) within Oxford's PSF is a vacuum chamber capable of simulating near-surface conditions for a range of solar system bodies by varying atmospheric pressure and incident solar irradiation. By varying the near-surface environment, the thermal gradient in the upper hundreds of microns of the sample is varied, which can affect the position and contrast of diagnostic features in TIR spectra. The atmospheric pressure inside the chamber is varied between 1000, 5 and < 10-4 mbar to simulate Earth, Mars and airless bodies (e.g. the Moon, Mars' moons and asteroids) conditions. The solar-like irradiation is varied by adjusting the power of the halogen lamp until the brightness temperature of the sample is similar to the brightness temperature of the simulated planetary body. Varying the sample packing in the sample cup simulates a range of near-surface porosities. Here we present laboratory emissivity spectra of a suite of well-characterized rock, soil and mineral samples (< 25 mm in particle size) measured under a range of simulated planetary conditions including Earth, Mars, Moon and asteroids. These well-controlled laboratory measurements enable the interpretation of remote sensing observations, which help in determining a planet's surface composition as well as the consolidated nature of its regolith.

  5. Simulating Near-Surface Environments of Solar System Bodies in the Laboratory

    Science.gov (United States)

    Donaldson Hanna, Kerri; Bowles, Neil

    2017-04-01

    Thermal infrared (TIR) emissivity measurements are sensitive to a planetary body's near-surface (upper hundreds of microns) environment, porosity and particle size, which make the interpretation of thermal infrared remote sensing observations of planetary surfaces challenging. Thus, well-constrained laboratory TIR measurements of analogue samples for a range of particle sizes, porosities and near-surface environments are needed. Near-surface environments and porosities for a range of solar system bodies can be simulated using facilities within University of Oxford's Planetary Spectroscopy Facility (PSF). The Simulated Lunar Environment Chamber (SLEC) within Oxford's PSF is a vacuum chamber capable of simulating near-surface conditions for a range of solar system bodies by varying atmospheric pressure and incident solar irradiation. By varying the near-surface environment, the thermal gradient in the upper hundreds of microns of the sample is varied, which can affect the position and contrast of diagnostic features in TIR spectra. The atmospheric pressure inside the chamber is varied between 1000, 5 and < 10-4 mbar to simulate Earth, Mars and airless bodies (e.g. the Moon, Mars' moons and asteroids) conditions. The solar-like irradiation is varied by adjusting the power of the halogen lamp until the brightness temperature of the sample is similar to the brightness temperature of the simulated planetary body. Varying the sample packing in the sample cup simulates a range of near-surface porosities. Here we present laboratory emissivity spectra of a suite of well-characterized rock, soil and mineral samples (< 25 microns in particle size) measured under a range of simulated planetary conditions including Earth, Mars, Moon and asteroids. These well-controlled laboratory measurements enable the interpretation of remote sensing observations, which help in determining a planet's surface composition as well as the consolidated nature of its regolith.

  6. Field and laboratory emission cell automation and control system for investigating surface chemistry reactions

    Science.gov (United States)

    Flemmer, Michael M.; Ham, Jason E.; Wells, J. R.

    2007-01-01

    A novel system [field and laboratory emission cell (FLEC) automation and control system] has been developed to deliver ozone to a surface utilizing the FLEC to simulate indoor surface chemistry. Ozone, humidity, and air flow rate to the surface were continuously monitored using an ultraviolet ozone monitor, humidity, and flow sensors. Data from these sensors were used as feedback for system control to maintain predetermined experimental parameters. The system was used to investigate the chemistry of ozone with α-terpineol on a vinyl surface over 72h. Keeping all other experimental parameters the same, volatile organic compound emissions from the vinyl tile with α-terpineol were collected from both zero and 100ppb(partsper109) ozone exposures. System stability profiles collected from sensor data indicated experimental parameters were maintained to within a few percent of initial settings. Ozone data from eight experiments at 100ppb (over 339h) provided a pooled standard deviation of 1.65ppb and a 95% tolerance of 3.3ppb. Humidity data from 17 experiments at 50% relative humidity (over 664h) provided a pooled standard deviation of 1.38% and a 95% tolerance of 2.77%. Data of the flow rate of air flowing through the FLEC from 14 experiments at 300ml/min (over 548h) provided a pooled standard deviation of 3.02ml/min and a 95% tolerance range of 6.03ml/min. Initial experimental results yielded long term emissions of ozone/α-terpineol reaction products, suggesting that surface chemistry could play an important role in indoor environments.

  7. An Overview of the Naval Research Laboratory Ocean Surface Flux (NFLUX) System

    Science.gov (United States)

    May, J. C.; Rowley, C. D.; Barron, C. N.

    2016-02-01

    The Naval Research Laboratory (NRL) ocean surface flux (NFLUX) system is an end-to-end data processing and assimilation system used to provide near-real time satellite-based surface heat flux fields over the global ocean. Swath-level air temperature (TA), specific humidity (QA), and wind speed (WS) estimates are produced using multiple polynomial regression algorithms with inputs from satellite sensor data records from the Special Sensor Microwave Imager/Sounder, the Advanced Microwave Sounding Unit-A, the Advanced Technology Microwave Sounder, and the Advanced Microwave Scanning Radiometer-2 sensors. Swath-level WS estimates are also retrieved from satellite environmental data records from WindSat, the MetOp scatterometers, and the Oceansat scatterometer. Swath-level solar and longwave radiative flux estimates are produced utilizing the Rapid Radiative Transfer Model for Global Circulation Models (RRTMG). Primary inputs to the RRTMG include temperature and moisture profiles and cloud liquid and ice water paths from the Microwave Integrated Retrieval System. All swath-level satellite estimates undergo an automated quality control process and are then assimilated with atmospheric model forecasts to produce 3-hourly gridded analysis fields. The turbulent heat flux fields, latent and sensible heat flux, are determined from the Coupled Ocean-Atmosphere Response Experiment (COARE) 3.0 bulk algorithms using inputs of TA, QA, WS, and a sea surface temperature model field. Quality-controlled in situ observations over a one-year time period from May 2013 through April 2014 form the reference for validating ocean surface state parameter and heat flux fields. The NFLUX fields are evaluated alongside the Navy's operational global atmospheric model, the Navy Global Environmental Model (NAVGEM). NFLUX is shown to have smaller biases and lower or similar root mean square errors compared to NAVGEM.

  8. Free Surface Hydrodynamics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Investigates processes and interactions at the air-sea interface, and compares measurements to numerical simulations and field data. Typical phenomena of...

  9. Neural Systems Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — As part of the Electrical and Computer Engineering Department and The Institute for System Research, the Neural Systems Laboratory studies the functionality of the...

  10. Tactical Systems Integration Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Tactical Systems Integration Laboratory is used to design and integrate computer hardware and software and related electronic subsystems for tactical vehicles....

  11. Undergraduate Laboratory for Surface Science

    Science.gov (United States)

    Okumura, Mitchio; Beauchamp, Jesse L.; Dickert, Jeffrey M.; Essy, Blair R.; Claypool, Christopher L.

    1996-02-01

    Surface science has developed into a multidisciplinary field of research with applications ranging from heterogeneous catalysis to semiconductor etching (1). Aspects of surface chemistry are now included in physical chemistry textbooks (2) and undergraduate curricula (3), but the perceived cost and complexity of equipment has deterred the introduction of surface science methods in undergraduate laboratories (4). Efforts to expose chemistry undergraduates to state-of-the-art surface instrumentation have just begun (5). To provide our undergraduates with hands-on experience in using standard techniques for characterizing surface morphology, adsorbates, kinetics, and reaction mechanisms, we have developed a set of surface science experiments for our physical chemistry laboratory sequence. The centerpiece of the laboratory is an ultrahigh vacuum (UHV) chamber for studies of single crystal surfaces. This instrument, shown in the figure, has surface analysis capabilities including low energy electron diffraction (LEED), Auger spectroscopy, and temperature-programmed desorption (TPD). The laboratory exercises involve experiments on the well-studied Pt(111) surface. Students prepare a previously mounted single crystal sample by sputtering it with an argon ion gun and heating it under O2. Electron diffraction patterns from the cleaned surface are then obtained with a reverse view LEED apparatus (Princeton Instruments). Images are captured by a charge-coupled device (CCD) camera interfaced to a personal computer for easy downloading and subsequent analysis. Although the LEED images from a Pt(111) surface can be readily interpreted using simple diffraction arguments, this lab provides an excellent context for introducing Miller indices and reciprocal lattices (6). The surface chemical composition can be investigated by Auger spectroscopy, using the LEED apparatus as a simple energy analyzer. The temperature programmed desorption experiment, which is nearly complete, will be

  12. Probabilistic risk assessment for the Sandia National Laboratories Technical Area V Liquid Waste Disposal System surface impoundments

    International Nuclear Information System (INIS)

    Dawson, L.A.; Eidson, A.F.

    1996-01-01

    A probabilistic risk assessment was completed for a former radioactive waste disposal site. The site, two unlined surface impoundment, was designed as part of the Liquid Waste Disposal System (LWDS) to receive radioactive effluent from nuclear reactors in Technical Area-V (TA-V) at Sandia National Laboratories/New Mexico (SNL/NM). First, a statistical comparison of site sampling results to natural background, using EPA methods, and a spatial distribution analysis were performed. Risk assessment was conducted with SNL/NM's Probabilistic Risk Evaluation and Characterization Investigation System model. The risk assessment indicated that contamination from several constituents might have been high enough to require remediation. However, further analysis based on expected site closure activities and recent EPA guidance indicated that No Further Action was acceptable

  13. Characterizing Dust from Cutting Corian®, a Solid-Surface Composite Material, in a Laboratory Testing System.

    Science.gov (United States)

    Qi, Chaolong; Echt, Alan; Murata, Taichi K

    2016-06-01

    We conducted a laboratory test to characterize dust from cutting Corian(®), a solid-surface composite material, with a circular saw. Air samples were collected using filters and direct-reading instruments in an automatic laboratory testing system. The average mass concentrations of the total and respirable dusts from the filter samples were 4.78±0.01 and 1.52±0.01mg cm(-3), respectively, suggesting about 31.8% mass of the airborne dust from cutting Corian(®) is respirable. Analysis of the metal elements on the filter samples reveals that aluminum hydroxide is likely the dominant component of the airborne dust from cutting Corian(®), with the total airborne and respirable dusts containing 86.0±6.6 and 82.2±4.1% aluminum hydroxide, respectively. The results from the direct-reading instruments confirm that the airborne dust generated from cutting Corian(®) were mainly from the cutting process with very few particles released from the running circular saw alone. The number-based size distribution of the dusts from cutting Corian(®) had a peak for fine particles at 1.05 µm with an average total concentration of 871.9 particles cm(-3), and another peak for ultrafine particles at 11.8nm with an average total concentration of 1.19×10(6) particles cm(-3) The small size and high concentration of the ultrafine particles suggest additional investigation is needed to study their chemical composition and possible contribution to pulmonary effect. Published by Oxford University Press on behalf of the British Occupational Hygiene Society 2016.

  14. Low-level multicounter β/γ systems with external guards in surface and shallow underground laboratories

    International Nuclear Information System (INIS)

    Theodorsson, P.

    1997-01-01

    When weak samples are measured it is important that they can be given ample counting time in order to obtain satisfactory accuracy and that the background count rate can be checked well. This calls for a high counting capacity, which multidetectors can bring us. I will discuss development possibilities of low-level β/γ multidetector systems with an external anticosmic shield that will in many cases be operated in underground laboratories. These simple and low-cost system can frequently help us in increasing the number of detectors. Three concepts are combined in these systems: (1) multidetectors, (2) an external anticosmic (or guard) detector arrangement and (3) overburden shielding. (orig.)

  15. Low-level multicounter {beta}/{gamma} systems with external guards in surface and shallow underground laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Theodorsson, P. [Iceland Univ. (Iceland). Science Inst.

    1997-03-01

    When weak samples are measured it is important that they can be given ample counting time in order to obtain satisfactory accuracy and that the background count rate can be checked well. This calls for a high counting capacity, which multidetectors can bring us. I will discuss development possibilities of low-level {beta}/{gamma} multidetector systems with an external anticosmic shield that will in many cases be operated in underground laboratories. These simple and low-cost system can frequently help us in increasing the number of detectors. Three concepts are combined in these systems: (1) multidetectors, (2) an external anticosmic (or guard) detector arrangement and (3) overburden shielding. (orig.)

  16. Purdue Hydrogen Systems Laboratory

    International Nuclear Information System (INIS)

    Gore, Jay P.; Kramer, Robert; Pourpoint, Timothee L.; Ramachandran, P.V.; Varma, Arvind; Zheng, Yuan

    2011-01-01

    The Hydrogen Systems Laboratory in a unique partnership between Purdue University's main campus in West Lafayette and the Calumet campus was established and its capabilities were enhanced towards technology demonstrators. The laboratory engaged in basic research in hydrogen production and storage and initiated engineering systems research with performance goals established as per the USDOE Hydrogen, Fuel Cells, and Infrastructure Technologies Program. In the chemical storage and recycling part of the project, we worked towards maximum recycling yield via novel chemical selection and novel recycling pathways. With the basic potential of a large hydrogen yield from AB, we used it as an example chemical but have also discovered its limitations. Further, we discovered alternate storage chemicals that appear to have advantages over AB. We improved the slurry hydrolysis approach by using advanced slurry/solution mixing techniques. We demonstrated vehicle scale aqueous and non-aqueous slurry reactors to address various engineering issues in on-board chemical hydrogen storage systems. We measured the thermal properties of raw and spent AB. Further, we conducted experiments to determine reaction mechanisms and kinetics of hydrothermolysis in hydride-rich solutions and slurries. We also developed a continuous flow reactor and a laboratory scale fuel cell power generation system. The biological hydrogen production work summarized as Task 4.0 below, included investigating optimal hydrogen production cultures for different substrates, reducing the water content in the substrate, and integrating results from vacuum tube solar collector based pre and post processing tests into an enhanced energy system model. An automated testing device was used to finalize optimal hydrogen production conditions using statistical procedures. A 3 L commercial fermentor (New Brunswick, BioFlo 115) was used to finalize testing of larger samples and to consider issues related to scale up. Efforts

  17. Purdue Hydrogen Systems Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Jay P Gore; Robert Kramer; Timothee L Pourpoint; P. V. Ramachandran; Arvind Varma; Yuan Zheng

    2011-12-28

    The Hydrogen Systems Laboratory in a unique partnership between Purdue University's main campus in West Lafayette and the Calumet campus was established and its capabilities were enhanced towards technology demonstrators. The laboratory engaged in basic research in hydrogen production and storage and initiated engineering systems research with performance goals established as per the USDOE Hydrogen, Fuel Cells, and Infrastructure Technologies Program. In the chemical storage and recycling part of the project, we worked towards maximum recycling yield via novel chemical selection and novel recycling pathways. With the basic potential of a large hydrogen yield from AB, we used it as an example chemical but have also discovered its limitations. Further, we discovered alternate storage chemicals that appear to have advantages over AB. We improved the slurry hydrolysis approach by using advanced slurry/solution mixing techniques. We demonstrated vehicle scale aqueous and non-aqueous slurry reactors to address various engineering issues in on-board chemical hydrogen storage systems. We measured the thermal properties of raw and spent AB. Further, we conducted experiments to determine reaction mechanisms and kinetics of hydrothermolysis in hydride-rich solutions and slurries. We also developed a continuous flow reactor and a laboratory scale fuel cell power generation system. The biological hydrogen production work summarized as Task 4.0 below, included investigating optimal hydrogen production cultures for different substrates, reducing the water content in the substrate, and integrating results from vacuum tube solar collector based pre and post processing tests into an enhanced energy system model. An automated testing device was used to finalize optimal hydrogen production conditions using statistical procedures. A 3 L commercial fermentor (New Brunswick, BioFlo 115) was used to finalize testing of larger samples and to consider issues related to scale up

  18. Road Transportable Analytical Laboratory (RTAL) system

    International Nuclear Information System (INIS)

    1993-01-01

    The goal of this contractual effort is the development and demonstration of a Road Transportable Analytical Laboratory (RTAL) system to meet the unique needs of the Department of Energy (DOE) for rapid, accurate analysis of a wide variety of hazardous and radioactive contaminants in soil, groundwater, and surface waters. This laboratory system will be designed to provide the field and laboratory analytical equipment necessary to detect and quantify radionuclides, organics, heavy metals and other inorganics, and explosive materials. The planned laboratory system will consist of a set of individual laboratory modules deployable independently or as an interconnected group to meet each DOE site's specific needs

  19. Protective Systems Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — This laboratory is a 40 by 28 by 9 foot facility that is equipped with tools for the development of various items of control technology related to the transmission...

  20. The Computational Sensorimotor Systems Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Computational Sensorimotor Systems Lab focuses on the exploration, analysis, modeling and implementation of biological sensorimotor systems for both scientific...

  1. Propulsion Systems Laboratory, Bldg. 125

    Data.gov (United States)

    Federal Laboratory Consortium — The Propulsion Systems Laboratory (PSL) is NASAs only ground test facility capable of providing true altitude and flight speed simulation for testing full scale gas...

  2. Spectro-Polarimetry of Fine-Grained Ice and Dust Surfaces Measured in the Laboratory to Study Solar System Objects and Beyond

    Science.gov (United States)

    Poch, O.; Cerubini, R.; Pommerol, A.; Thomas, N.; Schmid, H. M.; Potin, S.; Beck, P.; Schmitt, B.; Brissaud, O.; Carrasco, N.; Szopa, C.; Buch, A.

    2017-12-01

    The polarization of the light is very sensitive to the size, morphology, porosity and composition of the scattering particles. As a consequence, polarimetric observations could significantly complement observations performed in total light intensity, providing additional constraints to interpret remote sensing observations of Solar System and extra-solar objects. This presentation will focus on measurements performed in the laboratory on carefully characterized surface samples, providing reference data that can be used to test theoretical models and predict or interpret spectro-polarimetric observations. Using methods developed in the Laboratory for Outflow Studies of Sublimating Materials (LOSSy) at the University of Bern, we produce well-characterized and reproducible surfaces made of water ice particles having different grain sizes and porosities, as well as mineral/organic dusts, pure or mixed together, as analogues of planetary or small bodies surfaces. These surface samples are illuminated with a randomly polarized light source simulating the Sun. The polarization of their scattered light is measured at multiple phase angles and wavelengths, allowing to study the shape of the polarimetric phase curves and their spectral dependence, with two recently developed setups: The POLarimeter for Icy Samples (POLICES), at the University of Bern, allows the measurement of the weak polarization of ice surfaces from 400 to 800 nm, with direct application to icy satellites. Using a precision Stokes polarimeter, this setup is also used to study the spectral variations of circular polarization in the light scattered by biotic versus abiotic surfaces. The Spectrogonio radiometer with cHanging Angles for Detection Of Weak Signals (SHADOWS), at IPAG (University of Grenoble Alpes), measures linear polarization spectra from 0.35 to 5 μm in the light scattered by dark meteorite powders or icy samples, with application to primitive objects of the Solar System (asteroids, comets).

  3. Semi-Autonomous Systems Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — VisionThe Semi-Autonomous Systems Lab focuses on developing a comprehensive framework for semi-autonomous coordination of networked robotic systems. Semi-autonomous...

  4. The ideal laboratory information system.

    Science.gov (United States)

    Sepulveda, Jorge L; Young, Donald S

    2013-08-01

    Laboratory information systems (LIS) are critical components of the operation of clinical laboratories. However, the functionalities of LIS have lagged significantly behind the capacities of current hardware and software technologies, while the complexity of the information produced by clinical laboratories has been increasing over time and will soon undergo rapid expansion with the use of new, high-throughput and high-dimensionality laboratory tests. In the broadest sense, LIS are essential to manage the flow of information between health care providers, patients, and laboratories and should be designed to optimize not only laboratory operations but also personalized clinical care. To list suggestions for designing LIS with the goal of optimizing the operation of clinical laboratories while improving clinical care by intelligent management of laboratory information. Literature review, interviews with laboratory users, and personal experience and opinion. Laboratory information systems can improve laboratory operations and improve patient care. Specific suggestions for improving the function of LIS are listed under the following sections: (1) Information Security, (2) Test Ordering, (3) Specimen Collection, Accessioning, and Processing, (4) Analytic Phase, (5) Result Entry and Validation, (6) Result Reporting, (7) Notification Management, (8) Data Mining and Cross-sectional Reports, (9) Method Validation, (10) Quality Management, (11) Administrative and Financial Issues, and (12) Other Operational Issues.

  5. Production Systems. Laboratory Activities.

    Science.gov (United States)

    Gallaway, Ann, Ed.

    This production systems guide provides teachers with learning activities for secondary students. Introductory materials include an instructional planning outline and worksheet, an outline of essential elements, domains and objectives, a course description, and a content outline. The guide contains 30 modules on the following topics: production…

  6. Lawrence Livermore National Laboratory Surface Water Protection: A Watershed Approach

    Energy Technology Data Exchange (ETDEWEB)

    Coty, J

    2009-03-16

    is largely developed yet its surface water system encompasses two arroyos, an engineered detention basin (Lake Haussmann), storm channels, and wetlands. Conversely, the more rural Site 300 includes approximately 7,000 acres of largely undeveloped land with many natural tributaries, riparian habitats, and wetland areas. These wetlands include vernal pools, perennial seeps, and emergent wetlands. The watersheds within which the Laboratory's sites lie provide local and community ecological functions and services which require protection. These functions and services include water supply, flood attenuation, groundwater recharge, water quality improvement, wildlife and aquatic habitats, erosion control, and (downstream) recreational opportunities. The Laboratory employs a watershed approach to protect these surface water systems. The intent of this approach, presented in this document, is to provide an integrated effort to eliminate or minimize any adverse environmental impacts of the Laboratory's operations and enhance the attributes of these surface water systems, as possible and when reasonable, to protect their value to the community and watershed. The Laboratory's watershed approach to surface water protection will use the U.S. Environmental Protection Agency's Watershed Framework and guiding principles of geographic focus, scientifically based management and partnerships1 as a foundation. While the Laboratory's unique site characteristics result in objectives and priorities that may differ from other industrial sites, these underlying guiding principles provide a structure for surface water protection to ensure the Laboratory's role in environmental stewardship and as a community partner in watershed protection. The approach includes pollution prevention, continual environmental improvement, and supporting, as possible, community objectives (e.g., protection of the San Francisco Bay watershed).

  7. Laboratory information management system proposal

    Energy Technology Data Exchange (ETDEWEB)

    Brown, B.; Schweitzer, S.; Adams, C.; White, S. [Tennessee Univ., Knoxville, TN (United States)

    1992-08-01

    The objectives of this paper is design a user friendly information management system using a relational database in order to: allow customers direct access to the system; provide customers with direct sample tracking capabilities; provide customers with more timely, consistent reporting; better allocate costs for analyses to appropriate customers; eliminate cumbersome and costly papertrails; and enhance facility utilization by laboratory personnel. The resultant savings through increased efficiency provided by this system should more than offset its cost in the long-term.

  8. Laboratory information management system proposal

    Energy Technology Data Exchange (ETDEWEB)

    Brown, B.; Schweitzer, S.; Adams, C.; White, S. (Tennessee Univ., Knoxville, TN (United States))

    1992-01-01

    The objectives of this paper is design a user friendly information management system using a relational database in order to: allow customers direct access to the system; provide customers with direct sample tracking capabilities; provide customers with more timely, consistent reporting; better allocate costs for analyses to appropriate customers; eliminate cumbersome and costly papertrails; and enhance facility utilization by laboratory personnel. The resultant savings through increased efficiency provided by this system should more than offset its cost in the long-term.

  9. Road Transportable Analytical Laboratory system

    International Nuclear Information System (INIS)

    Finger, S.M.; Keith, V.F.; Spertzel, R.O.; De Avila, J.C.; O'Donnell, M.; Vann, R.L.

    1993-09-01

    This developmental effort clearly shows that a Road Transportable Analytical Laboratory System is a worthwhile and achievable goal. The RTAL is designed to fully analyze (radioanalytes, and organic and inorganic chemical analytes) 20 samples per day at the highest levels of quality assurance and quality control. It dramatically reduces the turnaround time for environmental sample analysis from 45 days (at a central commercial laboratory) to 1 day. At the same time each RTAL system will save the DOE over $12 million per year in sample analysis costs compared to the costs at a central commercial laboratory. If RTAL systems were used at the eight largest DOE facilities (at Hanford, Savannah River, Fernald, Oak Ridge, Idaho, Rocky Flats, Los Alamos, and the Nevada Test Site), the annual savings would be $96,589,000. The DOE's internal study of sample analysis needs projects 130,000 environmental samples requiring analysis in FY 1994, clearly supporting the need for the RTAL system. The cost and time savings achievable with the RTAL system will accelerate and improve the efficiency of cleanup and remediation operations throughout the DOE complex

  10. Sandia Laboratories plutonium protection system

    International Nuclear Information System (INIS)

    Bernard, E.A.; Miyoshi, D.S.; Gutierrez, F.D.

    1977-01-01

    Sandia Laboratories is developing an improved plutonium protection system (PPS) to demonstrate new concepts for enhancing special nuclear materials safeguards. PPS concepts include separation of functions, real-time item accountability and improved means for control of materials, activities and personnel access. Physical barriers and a secure communications network are designed into the system to offer greater protection against sabotage, diversion and theft attempts. Prototype systems are being constructed at Hanford, Washington and Albuquerque, New Mexico and will be subjected to a comprehensive testing and evaluation program

  11. Aviation Information Systems Development Laboratory (AISDL)

    Data.gov (United States)

    Federal Laboratory Consortium — Purpose:The Aviation Information Systems Development Laboratory (AISDL) provides the tools, reconfigurability and support to ensure the quality and integrity of new...

  12. Region 7 Laboratory Information Management System

    Data.gov (United States)

    U.S. Environmental Protection Agency — This is metadata documentation for the Region 7 Laboratory Information Management System (R7LIMS) which maintains records for the Regional Laboratory. Any Laboratory...

  13. Quality system for Medical laboratories

    Directory of Open Access Journals (Sweden)

    Shiva Raj K.C.

    2015-03-01

    Full Text Available According to William Edwards Deming “Good quality does not necessarily mean high quality. Instead it means a predicable degree of uniformity and dependability at low cost with a quality suited to the market.” Whereas according to famous engineer and management consultant Joseph M. Juran quality is “fitness for purpose”. It should meet the customers’ expectations and requirements, should be cost effective.ISO began in 1926 as the International Federation of the National Standardizing Associations (ISA. The name, "ISO" was derived from the Greek word "isos" meaning "equal". (The relation to standards is that if two objects meet the same standard, they should be equal. This name eliminates any confusion that could result from the translation of "International Organization for Standardization" into different languages which would lead to different acronyms.In health sector, quality plays pivotal role, as it is directly related to patient’s care. Earlier time, health service was simple, quite safe but ineffective. Now health care system is an organizational system with more complex processes to deliver care. Medical laboratory service is an integral part in patient’s management system. So, for everyone involved in the treatment of the patient, the accuracy, reliability and safety of those services must be the primary concerns. Accreditation is a significant enabler of quality, thereby delivering confidence to healthcare providers, clinicians, the medical laboratories and the patients themselves.ISO announced meeting in Philadelphia to form a technical committee to develop a new standard for medical laboratory quality. It took 7 years for the creation of a new Quality standard for medical laboratories. It was named as “ISO 15189” and was first published in 2003. The ISO has released three versions of the standard. The first two were released in 2003 and 2007. In 2012, a revised and updated version of the standard, ISO 15189

  14. Robotics and Autonomous Systems Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Provides an environment for developing and evaluating intelligent software for both actual and simulated autonomous vehicles. Laboratory computers provide...

  15. The laboratory station for tyres grip testing on different surfaces

    Science.gov (United States)

    Kalinowski, K.; Grabowik, C.; Janik, W.; Ćwikła, G.; Skowera, M.

    2015-11-01

    The paper presents the conception of the device for tyre grip testing in the laboratory conditions. The main purpose is to provide a device working in confined spaces, which enables rapid changes of the tested samples of the road surfaces. Among the key assumptions the minimization of the device dimensions and the relative ease of transportation and mobility - the ability to quick assemble and disassemble were also assumed. The main components of the projected workstation includes: the replaceable platform for mounting samples of a road surface, the roller conveyor, the drive of the platform, the wheel mounting assembly and the axial force measuring system. At the design the station a morphological structure method has been used, particular elements have been optimized individually.

  16. A Solar System Perspective on Laboratory Astrophysics

    Science.gov (United States)

    Cruikshank, Dale P.

    2002-01-01

    Planetary science deals with a wide variety of natural materials in a wide variety of environments. These materials include metals, minerals, ices, gases, plasmas, and organic chemicals. In addition, the newly defined discipline of astrobiology introduces biological materials to planetary science. The environments range from the interiors of planets with megapascal pressures to planetary magnetospheres, encompassing planetary mantles, surfaces, atmospheres, and ionospheres. The interplanetary environment includes magnetic and electrical fields, plasma, and dust. In order to understand planetary processes over these vast ranges, the properties of materials must be known, and most of the necessary information comes from the laboratory. Observations of the bodies and materials in the Solar System are accomplished over the full range of the electromagnetic spectrum by remote sensing from Earth or spacecraft. Comets exemplify this; molecular and atomic identifications are made from the hard ultraviolet to radio wavelengths, while X-rays are emitted as comets interact with the solar wind. Gamma rays from the surfaces of the Moon and asteroids are diagnostic of the mineral and ice content of those bodies; eventually, gamma rays will also be observed by probes to comets. A number of planetary materials are available in the laboratory for extensive Study: rocks from the Moon, Mars, several asteroids, as well as dust from comets (and perhaps the Kuiper Belt) are closely studied at every level, including atomic (isotopic). Even pre-solar interstellar grains isolated from meteorites are scrutinized for composition and crystalline structure. Beyond the materials themselves, various agents and processes have altered them over the 4.6-Gy age of the Solar System. Solar radiation, solar wind particles, trapped magnetospheric particles, cosmic rays, and micrometeoroid impacts have produced chemical, physical, and morphological changes in the atmospheres and on the surfaces of all

  17. Research System Integration Laboratory (SIL)

    Data.gov (United States)

    Federal Laboratory Consortium — The VEA Research SIL (VRS) is essential to the success of the TARDEC 30-Year Strategy. The vast majority of the TARDEC Capability Sets face challenging electronics...

  18. Simulation-Based System Design Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The research objective is to develop, test, and implement effective and efficient simulation techniques for modeling, evaluating, and optimizing systems in order to...

  19. Region 7 Laboratory Information Management System

    Science.gov (United States)

    This is metadata documentation for the Region 7 Laboratory Information Management System (R7LIMS) which maintains records for the Regional Laboratory. Any Laboratory analytical work performed is stored in this system which replaces LIMS-Lite, and before that LAST. The EPA and its contractors may use this database. The Office of Policy & Management (PLMG) Division at EPA Region 7 is the primary managing entity; contractors can access this database but it is not accessible to the public.

  20. Towards an Integrated Laboratory Information System

    OpenAIRE

    Boyarsky, M. William; Schneider, Dale E.; Lindbloom, Hali; Pickett, Michael P.; Schneider, Kenneth A.; Stead, William W.

    1989-01-01

    A pilot workstation in a project to integrate Laboratory Information System (LIS) function into an existing Hospital Information System is presented. The goal is to distribute local function while maintaining an integrated central database.

  1. Seawater circulating system in an aquaculture laboratory

    Digital Repository Service at National Institute of Oceanography (India)

    Chatterji, A.; Ingole, B.S.; Parulekar, A.H.

    The note gives an account, for the first time in India, of an Aquaculture Laboratory with open type seawater circulating system developed at the National Institute of Oceanography, Goa, India. Besides describing the details of the system...

  2. Intelligent Acquisition System Used in Mechanical Laboratory

    Directory of Open Access Journals (Sweden)

    Rob Raluca

    2016-01-01

    Full Text Available The main purpose of this paper consists in determining of the parameters which characterize the functioning of the Teves MK 60 as an ABS-ESP braking laboratory stand. This braking system model is used by the Volkswagen Golf and Bora the since 2002. The braking laboratory stand is able to simulate many operations which are able to give information concerning the ABS-ESP braking system comparing to the classical braking system. An application designed in LabVIEW comes to acquire and to process in real time the electrical signals generated by the Teves MK 60 laboratory stand.

  3. Laboratory Study of Dispersion of Buoyant Surface Plumes

    DEFF Research Database (Denmark)

    Petersen, Ole; Larsen, Torben

    1990-01-01

    A laboratory a study on surface dispersion of buoyant plumes in open channel turbulence in made, where the buoyancy is due to both salinity and heat. The measured parameters are the downstream derivative of a plume width and height, which are integral-characteristics of the distributions of density...

  4. Sandia Laboratories technical capabilities: systems analysis

    International Nuclear Information System (INIS)

    Lundergan, C.D.

    1975-06-01

    The systems analysis capabilities at Sandia Laboratories are summarized. Selected applications of these capabilities are presented to illustrate the extent to which they can be applied in research and development programs. (U.S.)

  5. Laboratory measurements of dusty surface charging in plasma.

    Science.gov (United States)

    Chou, Kevin; Wang, Joseph

    2017-09-01

    A novel method is developed to study the charging of a conducting surface covered by a thin dust layer in plasma. The potential profile in the dust layer and the floating potential of the surface underneath are measured directly by embedding conducting wires in the dust and connecting the wires to a measurement plate outside the vacuum chamber, where a Trek non-contacting electrostatic voltmeter measures the floating potential of the measurement plate. Laboratory experiments are carried out to study plasma charging of a conducting plate covered by lunar dust simulant, JSC-1A. The results show that the plate potential is dependent on both the ambient plasma condition and the dust layer thickness. The current balance condition controls the floating potential of the dust surface while the dust layer acts as a capacitor and controls the potential of the plate with respect to the dust surface. Hence, a dust covered conducting plate will be charged more negatively than a clean plate.

  6. Impact of surface water recharge on the design of a groundwater monitoring system for the Radioactive Waste Management Complex, Idaho National Engineering Laboratory

    International Nuclear Information System (INIS)

    Wood, T.R.

    1990-01-01

    Recent hydrogeologic studies have been initiated to characterize the hydrogeologic conditions at the Radioactive Waste Management Complex (RWMC) at the Idaho National Engineering Laboratory (INEL). Measured water levels in wells penetrating the Snake River Plain aquifer near the RWMC and the corresponding direction of flow show change over time. This change is related to water table mounding caused by recharge from excess water diverted from the Big Lost River for flood protection during high flows. Water levels in most wells near the RWMC rise on the order of 10 ft (3 m) in response to recharge, with water in one well rising over 60 ft (18 m). Recharge changes the normal south-southwest direction of flow to the east. Design of the proposed groundwater monitoring network for the RWMC must account for the variable directions of groundwater flow. 11 refs., 9 figs., 2 tabs

  7. Surface concrete decontamination equipment developed by Pacific Northwest Laboratory

    International Nuclear Information System (INIS)

    Halter, J.M.; Sullivan, R.G.; Bevan, J.L.

    1982-08-01

    This report documents a project that the Pacific Northwest Laboratory conducted to identify and develop techniques for removing contaminated concrete surfaces. A major problem associated with nuclear facility decontamination and decommissioning is how to economically demolish and dispose of contaminated concrete. Removing only the contaminated portion of the concrete can substantially reduce costs. Evaluation of various methods for removing concrete surfaces shows that several techniques presently used require excessive manpower, time, and energy. Many times more material is removed than necessary, increasing the quantity of waste that must be handled under controlled conditions. These evaluations generated the basic criteria for developing a suitable concrete removal technique: provide a convenient method for cleaning surfaces (such as those contaminated by a small spill); reduce the contaminated waste volume that has to be placed into controlled storage; remove surfaces quickly; and minimize personal exposure to potentially harmful radiation or toxic materials. Removal to 1/4 to 1/2 in. of contaminated surface layer is sufficient for cleanup of most facilities. Two unique decontamination methods have been developed: the concrete spaller and the water cannon. The concrete spaller is the most efficient technique: it removes the concrete surface faster than the water cannons and at a lower cost (as little as $3.00/ft 2 of concrete surface). However, the .458 magnum water cannon may be well suited for small or hard-to-reach locations

  8. Clinical and laboratory surface finishing procedures for zirconia on opposing human enamel wear: A laboratory study.

    Science.gov (United States)

    Chong, Bevan J; Thangavel, Arun K; Rolton, Shane B; Guazzato, Massimiliano; Klineberg, Iven J

    2015-10-01

    To investigate the effect of laboratory and clinical finishing procedures for zirconia on antagonistic enamel wear. Forty-eight yttria-tetragonal partially stabilised zirconia (Y-TZP) specimens were prepared and divided into four groups according to their surface preparation: laboratory polished (LP); laboratory polished and glazed (G); clinically adjusted (CA); and clinically adjusted and repolished (CAR). Enamel opposing enamel was used as a control. Pre-testing surface roughness for each group was determined using contact profilometry. Two-body wear resistance tests were conducted using a masticatory simulator. Enamel specimens were subjected to 120,000 cycles in distilled water (frequency 1.6 Hz, loading force of 49 N). Volumetric and vertical enamel losses were measured by superimposition of pre- and post-testing images using a three-dimensional laser scanner and software analysis. Scanning electron microscopy was used for qualitative surface analysis of pre- and post-testing zirconia and enamel surfaces. One-way ANOVA and multiple comparisons with Bonferroni corrections were used for statistical analysis at a significance level of α=0.05. There was no statistical difference in volumetric and vertical enamel loss between CAR, G and LP. CAR produced statistically significantly less volumetric enamel loss compared with CA and control, and statistically significantly less vertical enamel loss compared with CA. Volumetric and vertical enamel loss were highly correlated in all groups. Enamel wear by clinically ground zirconia is comparable to that of opposing enamel surfaces and greater than clinically repolished zirconia. Repolishing of zirconia restorations following clinical adjustment with diamond burs is effective in reducing antagonistic enamel wear. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Mars Science Laboratory Sample Acquisition, Sample Processing and Handling Subsystem: A Description of the Sampling Functionality of the System after being on the Surface for Two Years.

    Science.gov (United States)

    Beegle, L. W.; Anderson, R. C.; Abbey, W. J.

    2014-12-01

    The Sample Acquisition/Sample Processing and Handling (SA/SPaH) subsystem for the Mars Science Library (MSL) is a rover-based sampling system. SA/SPaH consists of a powdering drill and a scooping, sieving, and portioning device mounted on a turret at the end of a robotic arm. Curiosity rover preformed several sample acquisitions and processing of solid samples during its first year of operation. Material were processed and delivered to the two analytical instruments, Chemistry and Mineralogy (CheMin) and Sample Analysis at Mars (SAM), both of which required specific particle size for the material delivered to them to perform their analysis to determine its mineralogy and geochemistry content. In this presentation, the functionality of the system will be explained along with the in-situ targets the system has acquire and the samples that were delivered.

  10. CMDS System Integration and IAMD End-to-End Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Cruise Missile Defense Systems (CMDS) Project Office is establishing a secure System Integration Laboratory at the AMRDEC. This lab will contain tactical Signal...

  11. Assessment of laboratory logistics management information system ...

    African Journals Online (AJOL)

    Focus group discussion with the designated supply chain managers and key informant interviews were conducted for the qualitative method. Results: There exists a well-designed logistics system for laboratory commodities with trained pharmacy personnel, distributed standard LMIS formats and established inventory ...

  12. Road Transportable Analytical Laboratory system. Phase 1

    Energy Technology Data Exchange (ETDEWEB)

    Finger, S.M.; Keith, V.F.; Spertzel, R.O.; De Avila, J.C.; O`Donnell, M.; Vann, R.L.

    1993-09-01

    This developmental effort clearly shows that a Road Transportable Analytical Laboratory System is a worthwhile and achievable goal. The RTAL is designed to fully analyze (radioanalytes, and organic and inorganic chemical analytes) 20 samples per day at the highest levels of quality assurance and quality control. It dramatically reduces the turnaround time for environmental sample analysis from 45 days (at a central commercial laboratory) to 1 day. At the same time each RTAL system will save the DOE over $12 million per year in sample analysis costs compared to the costs at a central commercial laboratory. If RTAL systems were used at the eight largest DOE facilities (at Hanford, Savannah River, Fernald, Oak Ridge, Idaho, Rocky Flats, Los Alamos, and the Nevada Test Site), the annual savings would be $96,589,000. The DOE`s internal study of sample analysis needs projects 130,000 environmental samples requiring analysis in FY 1994, clearly supporting the need for the RTAL system. The cost and time savings achievable with the RTAL system will accelerate and improve the efficiency of cleanup and remediation operations throughout the DOE complex.

  13. HSI Prototypes for Human Systems Simulation Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Jokstad, Håkon [Idaho National Lab. (INL), Idaho Falls, ID (United States); McDonald, Rob [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-09-01

    This report describes in detail the design and features of three Human System Interface (HSI) prototypes developed by the Institutt for Energiteknikk (IFE) in support of the U.S. Department of Energy’s Light Water Reactor Sustainability Program under Contract 128420 through Idaho National Laboratory (INL). The prototypes are implemented for the Generic Pressurized Water Reactor simulator and installed in the Human Systems Simulation Laboratory at INL. The three prototypes are: 1) Power Ramp display 2) RCS Heat-up and Cool-down display 3) Estimated time to limit display The power ramp display and the RCS heat-up/cool-down display are designed to provide good visual indications to the operators on how well they are performing their task compared to their target ramp/heat-up/cool-down rate. The estimated time to limit display is designed to help operators restore levels or pressures before automatic or required manual actions are activated.

  14. Public health laboratory systems development in East Africa through ...

    African Journals Online (AJOL)

    Public health laboratory systems development in East Africa through training in laboratory management and field epidemiology. Fausta Mosha, Joseph Oundo, David Mukanga, Kariuki Njenga, Peter Nsubuga ...

  15. Mobile User Objective Systems (MUOS) Reference Implementation Laboratory (MRIL)

    Data.gov (United States)

    Federal Laboratory Consortium — The Mobile User Objective Systems (MUOS) Reference Implementation Laboratory (MRIL) performs verification and validation testing of various MUOS terminals. MRIL also...

  16. Chapter 3. System quality in chemical and radiochemical laboratories

    International Nuclear Information System (INIS)

    Rosskopfova, O.

    2006-01-01

    This chapter deals with the system quality in chemical and radiochemical laboratories. It contains following parts: requirement on management, system of management in laboratory, as well as system of the management

  17. Laboratory Reference Spectroscopy of Icy Satellite Candidate Surface Materials (Invited)

    Science.gov (United States)

    Dalton, J. B.; Jamieson, C. S.; Shirley, J. H.; Pitman, K. M.; Kariya, M.; Crandall, P.

    2013-12-01

    The bulk of our knowledge of icy satellite composition continues to be derived from ultraviolet, visible and infrared remote sensing observations. Interpretation of remote sensing observations relies on availability of laboratory reference spectra of candidate surface materials. These are compared directly to observations, or incorporated into models to generate synthetic spectra representing mixtures of the candidate materials. Spectral measurements for the study of icy satellites must be taken under appropriate conditions (cf. Dalton, 2010; also http://mos.seti.org/icyworldspectra.html for a database of compounds) of temperature (typically 50 to 150 K), pressure (from 10-9 to 10-3 Torr), viewing geometry, (i.e., reflectance), and optical depth (must manifest near infrared bands but avoid saturation in the mid-infrared fundamentals). The Planetary Ice Characterization Laboratory (PICL) is being developed at JPL to provide robust reference spectra for icy satellite surface materials. These include sulfate hydrates, hydrated and hydroxylated minerals, and both organic and inorganic volatile ices. Spectral measurements are performed using an Analytical Spectral Devices FR3 portable grating spectrometer from .35 to 2.5 microns, and a Thermo-Nicolet 6500 Fourier-Transform InfraRed (FTIR) spectrometer from 1.25 to 20 microns. These are interfaced with the Basic Extraterrestrial Environment Simulation Testbed (BEEST), a vacuum chamber capable of pressures below 10-9 Torr with a closed loop liquid helium cryostat with custom heating element capable of temperatures from 30-800 Kelvins. To generate optical constants (real and imaginary index of refraction) for use in nonlinear mixing models (i.e., Hapke, 1981 and Shkuratov, 1999), samples are ground and sieved to six different size fractions or deposited at varying rates to provide a range of grain sizes for optical constants calculations based on subtractive Kramers-Kronig combined with Hapke forward modeling (Dalton and

  18. Laboratory automation in clinical bacteriology: what system to choose?

    Science.gov (United States)

    Croxatto, A; Prod'hom, G; Faverjon, F; Rochais, Y; Greub, G

    2016-03-01

    Automation was introduced many years ago in several diagnostic disciplines such as chemistry, haematology and molecular biology. The first laboratory automation system for clinical bacteriology was released in 2006, and it rapidly proved its value by increasing productivity, allowing a continuous increase in sample volumes despite limited budgets and personnel shortages. Today, two major manufacturers, BD Kiestra and Copan, are commercializing partial or complete laboratory automation systems for bacteriology. The laboratory automation systems are rapidly evolving to provide improved hardware and software solutions to optimize laboratory efficiency. However, the complex parameters of the laboratory and automation systems must be considered to determine the best system for each given laboratory. We address several topics on laboratory automation that may help clinical bacteriologists to understand the particularities and operative modalities of the different systems. We present (a) a comparison of the engineering and technical features of the various elements composing the two different automated systems currently available, (b) the system workflows of partial and complete laboratory automation, which define the basis for laboratory reorganization required to optimize system efficiency, (c) the concept of digital imaging and telebacteriology, (d) the connectivity of laboratory automation to the laboratory information system, (e) the general advantages and disadvantages as well as the expected impacts provided by laboratory automation and (f) the laboratory data required to conduct a workflow assessment to determine the best configuration of an automated system for the laboratory activities and specificities. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. Laboratory use of industrial control systems

    International Nuclear Information System (INIS)

    Rijllart, A.; Avot, L.; Brahy, D.; Jegou, D.; Saban, R.

    1994-01-01

    Industrial control system manufacturers supply the building blocks for the control of industrial equipment or specific process control applications. Although the laboratory environment is different in many aspects (prototyping, evolution and frequent reconfiguration), the use of these building blocks remain attractive because of their general purpose nature, their cost and the large spectrum of available types. In this paper we present three projects which have been implemented using both industrial control system building blocks (PLCs, controllers, digital and analogue plug-in I/O cards) and commercial software packages (LabView and VisualBasic) for the man-machine interface, the data acquisition and archiving, and the process control. This approach has proved to be economical, easy and fast to implement. ((orig.))

  20. Laboratory robotics systems at the Savannah River Laboratory

    International Nuclear Information System (INIS)

    Dyches, G.M.; Burkett, S.D.

    1983-01-01

    Many analytical chemistry methods normally used at the Savannah River site require repetitive procedures and handling of radioactive and other hazardous solutions. Robotics is being investigated as a method of reducing personnel fatigue and radiation exposure and also increasing product quality. Several applications of various commercially available robot systems are discussed involving cold (nonradioactive) and hot (radioactive) sample preparations and glovebox waste removal. Problems encountered in robot programming, parts fixturing, design of special robot hands and other support equipment, glovebox operation, and operator-system interaction are discussed. A typical robot system cost analysis for one application is given

  1. Quality management system in hospital radiopharmacy laboratory

    International Nuclear Information System (INIS)

    Poch, Carolina; Rabiller, Graciela; Basualdo, Daniel A.; El Tamer, Elias A.

    2009-01-01

    Objective: 1) To determine the necessary conditions for increasing the complexity of the Radiopharmacy Laboratory and reach an operational level defined by the IAEA as 3a (Operational Guidance on Hospital Radiopharmacy). Our aim is that, within a framework of quality, last generation radiopharmaceuticals can be used, by sophisticated techniques such as labeling with bifunctional chelating agents, like HYNIC; 2) Consequently, we decided to implement a Quality Management System (QMS) in the field of Hospital Radiopharmacy in order to guarantee the safe and effective preparation and handling of radiopharmaceuticals for the diagnosis of patients, based on recommendations of the IAEA. Procedure For the implementation of the QMS, the sector of Radiopharmacy was capacitated in the application of ISO 9001. In a first stage it had begun with the formulation of the main documents and their enumeration. According to the recommendations of the IAEA Operational Guide, this year we proceeded to the optimization of the documents produced in the first stage and formulation of new documents essential to the improvement of work in the Radiopharmacy Laboratory. Results: Corrections were made to the performed procedures, and new ones were composed such as: Reception of raw materials, Control dose calibrator (Activity meter), General procedure of dosage, Procedure for decontamination, for Using the bio safety cabinet, for Cleaning the hot laboratory, etc. The Quality Controls were added to each of the Work Instructions of radiopharmaceuticals to be undertaken and how and when to carry out, with their respective references. Records were modified and new ones incorporated, in order to ensure traceability of the results before and after injection. Finally, the require documentation has been completed with the addition of the Staff Training Plan, and other records such as Nonconformance and Corrective and Preventive Actions. Conclusion: With the application of a QMS correctly implemented

  2. Computerized plutonium laboratory-stack monitoring system

    International Nuclear Information System (INIS)

    Stafford, R.G.; DeVore, R.K.

    1977-01-01

    The Los Alamos Scientific Laboratory has recently designed and constructed a Plutonium Research and Development Facility to meet design criteria imposed by the United States Energy Research and Development Administration. A primary objective of the design criteria is to assure environmental protection and to reliably monitor plutonium effluent via the ventilation exhaust systems. A state-of-the-art facility exhaust air monitoring system is described which establishes near ideal conditions for evaluating plutonium activity in the stack effluent. Total and static pressure sensing manifolds are incorporated to measure average velocity and integrated total discharge air volume. These data are logged at a computer which receives instrument data through a multiplex scanning system. A multipoint isokinetic sampling assembly with associated instrumentation is described. Continuous air monitors have been designed to sample from the isokinetic sampling assembly and transmit both instantaneous and integrated stack effluent concentration data to the computer and various cathode ray tube displays. The continuous air monitors also serve as room air monitors in the plutonium facility with the primary objective of timely evacuation of personnel if an above tolerance airborne plutonium concentration is detected. Several continuous air monitors are incorporated in the ventilation system to assist in identification of release problem areas

  3. Cooling systems research at Argonne National Laboratory

    International Nuclear Information System (INIS)

    Spigarelli, S.A.

    1977-01-01

    Studies of the thermal plumes resulting from discharges from once-through cooling systems of electric generating stations are reviewed. The collection of large amounts of water temperature data for definition of the three-dimensional structure of a thermal plume, of current data, and related ambient data for model evaluation purposes required the development of an integrated data collection system. The Argonne system employs measurements of water temperature over the water column from a moving small boat. Temperatures are measured with thermistors attached to a rigid strut for surface plumes and to a flexible, faired cable for submerged plumes. Water temperatures and boat location, determined by a microwave ranging system, are recorded on magnetic tape while the boat is underway and prove a quasi-synoptic map of plume temperatures. Automated data handling and processing procedures provide for the production of isotherm maps of the plume at several elevations and in cross section. Mathematical model evaluation for surface discharges of waste heat included the consideration of over 40 different models and detailed evaluation of 11 models. Most models were run on Argonne's computers, and all models were evaluated in terms of their limitations and capabilities as well as their predictive performance against prototype data. Measurements were made of thermal plumes at the discharges of nuclear power plants located on the shores of Lake Michigan

  4. Public health laboratory systems development in East Africa through training in laboratory management and field epidemiology.

    Science.gov (United States)

    Mosha, Fausta; Oundo, Joseph; Mukanga, David; Njenga, Kariuki; Nsubuga, Peter

    2011-01-01

    Laboratories are integral to the delivery of quality health care and for public health functions; however laboratory systems and services are often neglected in resource-poor settings such as the East African region. In order to sustainably strengthen national laboratory systems in resource-poor countries, there is a need to train laboratory personnel to work in clinical as well as public health laboratories. In 2004,Kenya, Uganda, Tanzania, and South Sudan began training public health laboratory workers jointly with field epidemiologists in the Kenya Field Epidemiology and Laboratory Training Program (FELTP), and later through the Tanzania FELTP, as a strategy to strengthen public health laboratories. These programs train laboratory epidemiologists through a two-year public health leadership development course, and also offer various types of short course training for frontline staff. The FELTP laboratory graduates in Kenya, Tanzania, Uganda, and South Sudan are working in their respective countries to strengthen public health laboratory systems while the short course participants provide a pool of frontline implementers with the capacity to support the lower tiers of health systems, as well as serve as surge capacity for the regions and the national level. Through training competent public health laboratory workers, the East African ministries of health, in collaboration with other regional partners and stakeholders are now engaged in developing and implementing a holistic approach that will guarantee an overall strengthening of the health system by using well-trained public health laboratory leaders to drive the process. Strengthening public health laboratory medicine in East Africa is critical to improve health-care systems. The experience with the FELTP model in East Africa is a step in the right direction towards ensuring a stronger role for the laboratory in public health.

  5. Laboratory information system data demonstrate successful ...

    African Journals Online (AJOL)

    The National Health Laboratory Service (NHLS) performs the PCR tests for the public health sector and stores test data in a corporate data warehouse (CDW). Objectives. To demonstrate the utility of laboratory data for monitoring trends in EID coverage and early vertical transmission rates and to describe the scale-up of the ...

  6. AUTOMATION OF THE SYSTEM OF INTERNAL LABORATORY QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    V. Z. Stetsyuk

    2015-05-01

    Full Text Available Quality control system base d on the principles of standardi zation of all phases of laboratory testing and analysis of internal laboratory quality control and external quality assessment. For the detection accuracy of the results of laboratory tests, carried out internally between the laboratory and laboratory quality control. Under internal laboratory quality control we understand measurement results of each analysis in each anal ytical series rendered directly in the lab every day. The purpose of internal laboratory control - identifying and eliminating unacceptable deviations from standard perfor mance test in the laboratory, i.e. identifying and eliminating harmful analytical errors. The solutions to these problems by implementing automated systems - software that allows you to optimize analytical laboratory research stage of the procedure by automatically creating process control charts was shown.

  7. Mining of hospital laboratory information systems

    DEFF Research Database (Denmark)

    Søeby, Karen; Jensen, Peter Bjødstrup; Werge, Thomas

    2015-01-01

    Abstract Background: The knowledge of physiological fluctuation and variation of even commonly used biochemical quantities in extreme age groups and during development is sparse. This challenges the clinical interpretation and utility of laboratory tests in these age groups. To explore the utility...... of hospital laboratory data as a source of information, we analyzed enzymatic plasma creatinine as a model analyte in two large pediatric hospital samples. Methods: Plasma creatinine measurements from 9700 children aged 0-18 years were obtained from hospital laboratory databases and partitioned into high...... in creatinine levels at different time points after birth and around the early teens, which challenges the establishment and usefulness of reference intervals in those age groups. Conclusions: The study documents that hospital laboratory data may inform on the developmental aspects of creatinine, on periods...

  8. Development of laboratory information management system

    OpenAIRE

    Tereshchenko, O. V.; Tereshchenko, A. G.; Tereshchenko, V. A.; Yanin, A. M.; Tolstikhina, T. V.

    2006-01-01

    Results of the actual direction of work of Scientific Research Institute of HV on development of the program complex LIS/LIMS «Chemist - analysts» for automatization of activity of analytical laboratories are presented. Functions of the complex and methodological principles of its development are considered, comparison with foreign analogues is carried out. The model of the industrial analytical control with use of concepts of a life cycle of a laboratory, technique and test is described.

  9. Washington Clinical Laboratory Initiative: a vision for collaboration and strategic planning for an integrated laboratory system.

    Science.gov (United States)

    Counts, J M

    2001-01-01

    This article addresses the importance of public health, hospital, and clinical laboratories in the role of patient care, disease prevention, and surveillance. It also focuses on the coordination and planning that needs to take place between these institutions in order to develop a more cost-effective and responsive laboratory delivery system. The Washington Clinical Laboratory Initiative is an innovative state initiative illustrating that coordinated and integrated strategic planning of public and private sector laboratories can be accomplished within a state. It also has increased interaction, collaboration, and communication between health practitioners, health plans, hospitals, laboratories, government agencies, and academicians. This accomplishment has enabled the establishment of public policy concerning laboratory reimbursement and development of standards of laboratory practice.

  10. [Knowledge management system for laboratory work and clinical decision support].

    Science.gov (United States)

    Inada, Masanori; Sato, Mayumi; Yoneyama, Akiko

    2011-05-01

    This paper discusses a knowledge management system for clinical laboratories. In the clinical laboratory of Toranomon Hospital, we receive about 20 questions relevant to laboratory tests per day from medical doctors or co-medical staff. These questions mostly involve the essence to appropriately accomplish laboratory tests. We have to answer them carefully and suitably because an incorrect answer may cause a medical accident. Up to now, no method has been in place to achieve a rapid response and standardized answers. For this reason, the laboratory staff have responded to various questions based on their individual knowledge. We began to develop a knowledge management system to promote the knowledge of staff working for the laboratory. This system is a type of knowledge base for assisting the work, such as inquiry management, laboratory consultation, process management, and clinical support. It consists of several functions: guiding laboratory test information, managing inquiries from medical staff, reporting results of patient consultation, distributing laboratory staffs notes, and recording guidelines for laboratory medicine. The laboratory test information guide has 2,000 records of medical test information registered in the database with flexible retrieval. The inquiry management tool provides a methos to record all questions, answer easily, and retrieve cases. It helps staff to respond appropriately in a short period of time. The consulting report system treats patients' claims regarding medical tests. The laboratory staffs notes enter a file management system so they can be accessed to aid in clinical support. Knowledge sharing using this function can achieve the transition from individual to organizational learning. Storing guidelines for laboratory medicine will support EBM. Finally, it is expected that this system will support intellectual activity concerning laboratory work and contribute to the practice of knowledge management for clinical work support.

  11. Fission Surface Power System Initial Concept Definition

    Science.gov (United States)

    2010-01-01

    Under the NASA Exploration Technology Development Program (ETDP) and in partnership with the Department of Energy (DOE), NASA has embarked on a project to develop Fission Surface Power (FSP) technology. The primary goals of the project are to 1) develop FSP concepts that meet expected surface power requirements at reasonable cost with added benefits over other options, 2) establish a hardwarebased technical foundation for FSP design concepts and reduce overall development risk, 3) reduce the cost uncertainties for FSP and establish greater credibility for flight system cost estimates, and 4) generate the key products to allow NASA decision-makers to consider FSP as a preferred option for flight development. The FSP project was initiated in 2006 as the Prometheus Program and the Jupiter Icy Moons Orbiter (JIMO) mission were phased-out. As a first step, NASA Headquarters commissioned the Affordable Fission Surface Power System Study to evaluate the potential for an affordable FSP development approach. With a cost-effective FSP strategy identified, the FSP team evaluated design options and selected a Preliminary Reference Concept to guide technology development. Since then, the FSP Preliminary Reference Concept has served as a point-of-departure for several NASA mission architecture studies examining the use of nuclear power and has provided the foundation for a series of "Pathfinder" hardware tests. The long-term technology goal is a Technology Demonstration Unit (TDU) integrated system test using full-scale components and a non-nuclear reactor simulator. The FSP team consists of Glenn Research Center (GRC), Marshall Space Flight Center (MSFC) and the DOE National Laboratories at Los Alamos (LANL), Idaho (INL), Oak Ridge (ORNL), and Sandia (SNL). The project is organized into two main elements: Concept Definition and Risk Reduction. Under Concept Definition, the team performs trade studies, develops analytical tools, and formulates system concepts. Under Risk

  12. Laboratory Assessment of the Infiltration Capacity Reduction in Clogged Porous Mixture Surfaces

    Directory of Open Access Journals (Sweden)

    Valerio C. Andrés-Valeri

    2016-08-01

    Full Text Available Permeable pavements have been used widely across the world to manage urban stormwater. The hydrological behaviour of permeable surfaces is a complex process affected by many factors, such as rainfall intensity, rainfall duration, pavement geometrical conditions, and clogging level of the permeable surface, amongst others. This laboratory study was carried out to assess the influence of clogging level and rainfall intensity on the infiltration capacity of porous mixture surfaces used in Permeable Pavement Systems (PPS. Porous Concrete (PC and Porous Asphalt (PA mixtures with different air void contents (15%, 20%, and 25% were subject to different clogging scenarios by using varying sediment loads (0, 500, and 1000 g/m2. Permeability experiments were carried out for each clogging scenario through a new rainfall simulator specially developed, tailored, and calibrated for the laboratory simulation of a wide range of rainfall events. Permeability measurements were taken under all different scenarios as a result of the combination of the different rainfall events (50, 100, and 150 mm/h simulated over the specimens of porous mixtures and the sediment loads applied to them. The results showed that the PC mixtures tested perform better than the PA ones in terms of infiltration capacity, showing less potential for clogging and being more easily cleaned by the wash-off produced by the simulated rainfall events.

  13. Laboratory services series: a programmed maintenance system

    Energy Technology Data Exchange (ETDEWEB)

    Tuxbury, D.C.; Srite, B.E.

    1980-01-01

    The diverse facilities, operations and equipment at a major national research and development laboratory require a systematic, analytical approach to operating equipment maintenance. A computer-scheduled preventive maintenance program is described including program development, equipment identification, maintenance and inspection instructions, scheduling, personnel, and equipment history.

  14. Expert Systems for the Analytical Laboratory.

    Science.gov (United States)

    de Monchy, Allan R.; And Others

    1988-01-01

    Discusses two computer problem solving programs: rule-based expert systems and decision analysis expert systems. Explores the application of expert systems to automated chemical analyses. Presents six factors to consider before using expert systems. (MVL)

  15. Dynamic surface deformation of silicone elastomers for management of marine biofouling: laboratory and field studies using pneumatic actuation.

    Science.gov (United States)

    Shivapooja, Phanindhar; Wang, Qiming; Szott, Lizzy M; Orihuela, Beatriz; Rittschof, Daniel; Zhao, Xuanhe; López, Gabriel P

    2015-01-01

    Many strategies have been developed to improve the fouling release (FR) performance of silicone coatings. However, biofilms inevitably build on these surfaces over time. Previous studies have shown that intentional deformation of silicone elastomers can be employed to detach biofouling species. In this study, inspired by the methods used in soft-robotic systems, controlled deformation of silicone elastomers via pneumatic actuation was employed to detach adherent biofilms. Using programmed surface deformation, it was possible to release > 90% of biofilm from surfaces in both laboratory and field environments. A higher substratum strain was required to remove biofilms accumulated in the field environment as compared with laboratory-grown biofilms. Further, the study indicated that substratum modulus influences the strain needed to de-bond biofilms. Surface deformation-based approaches have potential for use in the management of biofouling in a number of technological areas, including in niche applications where pneumatic actuation of surface deformation is feasible.

  16. Laboratory screening of some saprophytic coffee surface microflora ...

    African Journals Online (AJOL)

    La microflore saprophyte de surface a été isolée des baies de café. Huit isolats ont été sélectionnés pour les tests d\\'antagonisme contre Colletotrichum kahawae. Six isolats (Bacillus macerans [deux isolats], Epicoccum nigrum, Aspergillus niger, Penicillium citrinum et Pestalotiopsis sp) ont été sélectionnés pour avoir ...

  17. Laboratory Information Management System Chain of Custody: Reliability and Security

    OpenAIRE

    Tomlinson, J. J.; Elliott-Smith, W.; Radosta, T.

    2006-01-01

    A chain of custody (COC) is required in many laboratories that handle forensics, drugs of abuse, environmental, clinical, and DNA testing, as well as other laboratories that want to assure reliability of reported results. Maintaining a dependable COC can be laborious, but with the recent establishment of the criteria for electronic records and signatures by US regulatory agencies, laboratory information management systems (LIMSs) are now being developed to fully automate COCs. The extent of a...

  18. Laboratory Tests of Small SDHW Systems

    DEFF Research Database (Denmark)

    Furbo, Simon; Shah, Louise Jivan

    1997-01-01

    as foreign manufacturers have been tested.The thermal performances of the systems have been measured for periods with a duration of about 1 year. In this way direct comparisons of the thermal performances of the different systems are possible.Further, measured and calculated thermal performances for all...... models the yearly thermal performances of the tested systems have been determined with the Danish Test Reference Year as the weather data. Based on calculations with the models improvements of the design of the different systems have been recommended.Experience from the operation of the different systems...

  19. Road Transportable Analytical Laboratory (RTAL) system

    International Nuclear Information System (INIS)

    1994-12-01

    The problem of groundwater contamination at a large number of industrial facilities is well known. Many US Army and Department of Energy (DOE) facilities share this problem of potentially contaminated water as a result of past disposal practices associated with military and energy source development activities. A wide range of contaminants are found at certain installations encompassing industrial pollutants and military-unique materials. The US Army Biomedical Research and Development Laboratory has been conducting research for a number of years on developing better means to determine the hazards associated with exposure to these types of complex mixtures. The methods involve the use of aquatic organisms together with in vitro mutagenicity assays and analytical chemistry in an integrated biological assessment of a specific site. Integrated Biological Assessment is an important development in the Army's continuing efforts to locate, clean and monitor sites contaminated as a result of military operations. This method provides meaningful hazard data regarding whether a test medium contains low levels of industrial or military-unique contaminants. This is an important advance in determining which sites are clean and which require remediation. It provides continuing monitoring of the effectiveness of remediation operations. Engineering Computer Opteconomics (ECO), Inc. was tasked, in a collaborative Army and DOE effort, to develop a transportable Integrated Biological Assessment Laboratory Complex. This multimodular Complex is designed to be taken into remote areas to provide the necessary long-term on-site research for determining hazards from low levels of contamination in the environment. Each module of the Complex is designed to be self-sufficient, to provide a safe environment for the operators, and a controlled environment for the test organisms and related critical chemical and biological analyses

  20. Capabilities of the DOE Remote Sensing Laboratory`s aerial measuring system

    Energy Technology Data Exchange (ETDEWEB)

    Riedhauser, S.R.

    1995-09-01

    This report describes the capabilities of the Remote Sensing Laboratory`s aircraft for use in environmental radiation surveys, multispectral (visible, near infrared, and thermal infrared) surveys of vegetation and buildings, and photographic documentation of the areas covered by the two other surveys. The report discusses the technical capabilities of the various systems and presents examples of the data from a recent demonstration survey. To provide a view of the types of surveys the Remote Sensing Laboratory has conducted in the past, the appendices describe several of the previous area surveys and emergency search surveys.

  1. Multipurpose laboratory test system applying CAMAC standards

    Energy Technology Data Exchange (ETDEWEB)

    Bowers, J.L.

    1976-11-01

    A flexible electronic product test and evaluation system is proposed. A system study was performed to determine how increasingly complex telemetry systems could be effectively evaluated during development and preproduction and after first production units were built. A primary requirement was that this system remain flexible with respect to configuration and mission and that it be easily maintainable. In addition, the system must be upgraded easily as old product requirements and definitions are replaced by new designs. As a result of this study it is concluded that this project would involve the expenditure of considerable funds and manpower at the beginning of the project and that the cost effectiveness of the system would be dependent upon its utilization and management. This study also demonstrates how the use of computer interface hardware standards (IEEE 583) can minimize requirements for expensive specially designed test equipment for each application.

  2. Signals and systems laboratory with Matlab

    CERN Document Server

    Palamides, Alex

    2010-01-01

    Introduction to MATLAB®Working EnvironmentGetting StartedMemory ManagementVectorsMatricesPlotting with MATLABComplex NumbersM-FilesInput-Output CommandsFile ManagementLogical-Relational OperatorsControl FlowSymbolic VariablesPolynomials(Pseudo)Random NumbersSignalsCategorization by the Variable TypeBasic Continuous-Time SignalsDiscrete-Time SignalsProperties of SignalsTransformations of the Time Variable for Continuous-Time SignalsTransformations of the Time Variable for Discrete-Time SignalsSystemsSystems ClassificationProperties of SystemsTime Domain System AnalysisImpulse ResponseContinuous Time Convolution Convolution PropertiesInterconnections of SystemsStabilityDiscrete-Time ConvolutionSystems Described by Difference EquationsFiltersStability Criterion for Discrete-Time SystemsSystems Described by Differential EquationsStep Response of a SystemFourier SeriesOrthogonality of Complex Exponential SignalsComplex Exponential Fourier SeriesTrigonometric Fourier SeriesFourier Series in the Cosine with Phase F...

  3. Laboratory Control System's Effects on Student Achievement and Attitudes

    Science.gov (United States)

    Cicek, Fatma Gozalan; Taspinar, Mehmet

    2016-01-01

    Problem Statement: The current study investigates whether the learning environment designed based on the laboratory control system affects the academic achievement, the attitude toward the learning-teaching process and the retention of the students in computer education. Purpose of Study: The study aims to identify the laboratory control system…

  4. Challenges in small screening laboratories: implementing an on-demand laboratory information management system.

    Science.gov (United States)

    Lemmon, Vance P; Jia, Yuanyuan; Shi, Yan; Holbrook, S Douglas; Bixby, John L; Buchser, William

    2011-11-01

    The Miami Project to Cure Paralysis, part of the University of Miami Miller School of Medicine, includes a laboratory devoted to High Content Analysis (HCA) of neurons. The goal of the laboratory is to uncover signaling pathways, genes, compounds, or drugs that can be used to promote nerve growth. HCA permits the quantification of neuronal morphology, including the lengths and numbers of axons. HCA of various libraries on primary neurons requires a team-based approach, a variety of process steps and complex manipulations of cells and libraries to obtain meaningful results. HCA itself produces vast amounts of information including images, well-based data and cell-based phenotypic measures. Documenting and integrating the experimental workflows, library data and extensive experimental results is challenging. For academic laboratories generating large data sets from experiments involving thousands of perturbagens, a Laboratory Information Management System (LIMS) is the data tracking solution of choice. With both productivity and efficiency as driving rationales, the Miami Project has equipped its HCA laboratory with an On Demand or Software As A Service (SaaS) LIMS to ensure the quality of its experiments and workflows. The article discusses how the system was selected and integrated into the laboratory. The advantages of a SaaS based LIMS over a client-server based system are described. © 2011 Bentham Science Publishers

  5. Distilled Water Distribution Systems. Laboratory Design Notes.

    Science.gov (United States)

    Sell, J.C.

    Factors concerning water distribution systems, including an evaluation of materials and a recommendation of materials best suited for service in typical facilities are discussed. Several installations are discussed in an effort to bring out typical features in selected applications. The following system types are included--(1) industrial…

  6. A laboratory based x-ray reflectivity system

    International Nuclear Information System (INIS)

    Holt, S.A.; Creagh, D.C.; Jamie, I.M.; Dowling, T.L.; Brown, A.S.

    1996-01-01

    Full text: X-ray Reflectivity (XRR) over the last decade has proved to be a versatile and powerful technique by which the thickness of thin films, surface roughness and interface roughness can be determined. The systems amenable to study range from organic monolayers (liquid or solid substrates) to layered metal or semiconductor systems. Access to XRR has been limited by the requirement for synchrotron radiation sources. The development of XRR systems for the laboratory environment was pioneered by Weiss. An X-ray Reflectometer has been constructed by the Department of Physics (Australian Defence Force Academy) and the Research School of Chemistry (Australian National University). The general principles of the design were similar to those described by Weiss. The reflectometer is currently in the early stages of commissioning, with encouraging results thus far. The diffraction pattern of Mobil Catalytic Material (MCM), consisting primarily of SiO 2 . The poster will describe the reflectometer, its operation and present a summary of the most important results obtained to date

  7. Hazardous waste systems analysis at Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    Urioste, J.

    1997-01-01

    Los Alamos National Laboratory produces routine and non-routine hazardous waste as a by-product of mission operations. Hazardous waste commonly generated at the Laboratory includes many types of laboratory research chemicals, solvents, acids, bases, carcinogens, compressed gases, metals, and other solid waste contaminated with hazardous waste. The Los Alamos National Laboratory Environmental Stewardship Office has established a Hazardous Waste Minimization Coordinator to specifically focus on routine and non-routine RCRA, TSCA, and other administratively controlled wastes. In this process, the Waste Minimization Coordinator has developed and implemented a systems approach to define waste streams, estimate waste management costs and develop plans to implement avoidance practices, and develop projects to reduce or eliminate the waste streams at the Laboratory. The paper describes this systems approach

  8. Microwave system for research biological effects on laboratory animals

    OpenAIRE

    Kopylov, Alexei; Kruglik, Olga; Khlebopros, Rem

    2014-01-01

    This research is concerned with development of the microwave system for research the radiophysical microwave radiation effects on laboratory animals. The frequency was 1 GHz. The results obtained demonstrate the metabolic changes in mice under the electromagnetic field influence.

  9. DEMONSTRATION BULLETIN: IN SITU ELECTROKINETIC EXTRACTION SYSTEM - SANDIA NATIONAL LABORATORIES

    Science.gov (United States)

    Sandia National Laboratories (SNL) has developed an in situ soil remediation system that uses electrokinetic principles to remediate hexavalent chromium-contaminated unsaturated or partially saturated soils. The technology involves the in situ application of direct current to the...

  10. The Laboratory Efficiencies Initiative: Partnership for Building a Sustainable National Public Health Laboratory System

    Science.gov (United States)

    Moulton, Anthony D.; Ned, Renée M.; Nicholson, Janet K.A.; Chu, May C.; Becker, Scott J.; Blank, Eric C.; Breckenridge, Karen J.; Waddell, Victor; Brokopp, Charles

    2013-01-01

    Beginning in early 2011, the Centers for Disease Control and Prevention and the Association of Public Health Laboratories launched the Laboratory Efficiencies Initiative (LEI) to help public health laboratories (PHLs) and the nation's entire PHL system achieve and maintain sustainability to continue to conduct vital services in the face of unprecedented financial and other pressures. The LEI focuses on stimulating substantial gains in laboratories' operating efficiency and cost efficiency through the adoption of proven and promising management practices. In its first year, the LEI generated a strategic plan and a number of resources that PHL directors can use toward achieving LEI goals. Additionally, the first year saw the formation of a dynamic community of practitioners committed to implementing the LEI strategic plan in coordination with state and local public health executives, program officials, foundations, and other key partners. PMID:23997300

  11. A prospective survey of air and surface fungal contamination in a medical mycology laboratory at a tertiary care university hospital.

    Science.gov (United States)

    Sautour, Marc; Dalle, Frédéric; Olivieri, Claire; L'ollivier, Coralie; Enderlin, Emilie; Salome, Elsa; Chovelon, Isabelle; Vagner, Odile; Sixt, Nathalie; Fricker-Pap, Véronique; Aho, Serge; Fontaneau, Olivier; Cachia, Claire; Bonnin, Alain

    2009-04-01

    Invasive filamentous fungi infections resulting from inhalation of mold conidia pose a major threat in immunocompromised patients. The diagnosis is based on direct smears, cultural symptoms, and culturing fungi. Airborne conidia present in the laboratory environment may cause contamination of cultures, resulting in false-positive diagnosis. Baseline values of fungal contamination in a clinical mycology laboratory have not been determined to date. A 1-year prospective survey of air and surface contamination was conducted in a clinical mycology laboratory during a period when large construction projects were being conducted in the hospital. Air was sampled with a portable air system impactor, and surfaces were sampled with contact Sabouraud agar plates. The collected data allowed the elaboration of Shewhart graphic charts. Mean fungal loads ranged from 2.27 to 4.36 colony forming units (cfu)/m(3) in air and from 0.61 to 1.69 cfu/plate on surfaces. Strict control procedures may limit the level of fungal contamination in a clinical mycology laboratory even in the context of large construction projects at the hospital site. Our data and the resulting Shewhart graphic charts provide baseline values to use when monitoring for inappropriate variations of the fungal contamination in a mycology laboratory as part of a quality assurance program. This is critical to the appropriate management of the fungal risk in hematology, cancer and transplantation patients.

  12. Laboratory system for alpha particle spectroscopy

    International Nuclear Information System (INIS)

    Dean, J.R.; Chiu, N.W.

    1987-03-01

    An automated alpha particle spectroscopy system has beeen designed and fabricated. It consists of two major components, the automatic sample changer and the controller/data acquisition unit. It is capable of unattended analysis of ten samples for up to 65,000 seconds per sample

  13. Laboratory Information Management System Chain of Custody: Reliability and Security

    Science.gov (United States)

    Tomlinson, J. J.; Elliott-Smith, W.; Radosta, T.

    2006-01-01

    A chain of custody (COC) is required in many laboratories that handle forensics, drugs of abuse, environmental, clinical, and DNA testing, as well as other laboratories that want to assure reliability of reported results. Maintaining a dependable COC can be laborious, but with the recent establishment of the criteria for electronic records and signatures by US regulatory agencies, laboratory information management systems (LIMSs) are now being developed to fully automate COCs. The extent of automation and of data reliability can vary, and FDA- and EPA-compliant electronic signatures and system security are rare. PMID:17671623

  14. Laboratory information management system chain of custody: reliability and security.

    Science.gov (United States)

    Tomlinson, J J; Elliott-Smith, W; Radosta, T

    2006-01-01

    A chain of custody (COC) is required in many laboratories that handle forensics, drugs of abuse, environmental, clinical, and DNA testing, as well as other laboratories that want to assure reliability of reported results. Maintaining a dependable COC can be laborious, but with the recent establishment of the criteria for electronic records and signatures by US regulatory agencies, laboratory information management systems (LIMSs) are now being developed to fully automate COCs. The extent of automation and of data reliability can vary, and FDA- and EPA-compliant electronic signatures and system security are rare.

  15. Laboratory Information Management System (LIMS): A case study

    Science.gov (United States)

    Crandall, Karen S.; Auping, Judith V.; Megargle, Robert G.

    1987-01-01

    In the late 70's, a refurbishment of the analytical laboratories serving the Materials Division at NASA Lewis Research Center was undertaken. As part of the modernization efforts, a Laboratory Information Management System (LIMS) was to be included. Preliminary studies indicated a custom-designed system as the best choice in order to satisfy all of the requirements. A scaled down version of the original design has been in operation since 1984. The LIMS, a combination of computer hardware, provides the chemical characterization laboratory with an information data base, a report generator, a user interface, and networking capabilities. This paper is an account of the processes involved in designing and implementing that LIMS.

  16. SETTING UP AN INDUSTRIAL CONTROL SYSTEMS LABORATORY

    Directory of Open Access Journals (Sweden)

    Haryanto Natalius Liuwan

    2014-01-01

    Full Text Available With the evolution of Industrial Control Systems, many solutions from vendors are offered for industries. But sadly, most of those solutions are close-sourced, delivering lack of support for third parties who aim to develop Industrial Control Systems further. A start-up company named SecurityMatters needs an industrial instrument to simulate industrial environment to have a better idea how a particular protocol works. The application made in this project was developed using Java programming language to have compatibilities across platforms. An Object-Oriented-Programming and Model-View-Controller pattern are used as well to ensure maintainability. This application can be used to demonstrate capabilities of Modbus protocol and test industrial devices for vulnerabilities.

  17. Laboratory system strengthening and quality improvement in Ethiopia

    Directory of Open Access Journals (Sweden)

    Tilahun M. Hiwotu

    2014-11-01

    Full Text Available Background: In 2010, a National Laboratory Strategic Plan was set forth in Ethiopia to strengthen laboratory quality systems and set the stage for laboratory accreditation. As a result, the Strengthening Laboratory Management Toward Accreditation (SLMTA programme was initiated in 45 Ethiopian laboratories. Objectives: This article discusses the implementation of the programme, the findings from the evaluation process and key challenges. Methods: The 45 laboratories were divided into two consecutive cohorts and staff from each laboratory participated in SLMTA training and improvement projects. The average amount of supportive supervision conducted in the laboratories was 68 hours for cohort I and two hoursfor cohort II. Baseline and exit audits were conducted in 44 of the laboratories and percent compliance was determined using a checklist with scores divided into zero- to five-star ratinglevels. Results: Improvements, ranging from < 1 to 51 percentage points, were noted in 42 laboratories, whilst decreases were recorded in two. The average scores at the baseline and exit audits were 40% and 58% for cohort I (p < 0.01; and 42% and 53% for cohort II (p < 0.01,respectively. The p-value for difference between cohorts was 0.07. At the exit audit, 61% ofthe first and 48% of the second cohort laboratories achieved an increase in star rating. Poor awareness, lack of harmonisation with other facility activities and the absence of a quality manual were challenges identified. Conclusion: Improvements resulting from SLMTA implementation are encouraging. Continuous advocacy at all levels of the health system is needed to ensure involvement of stakeholders and integration with other improvement initiatives and routine activities.

  18. Monitoring system of the Tritium Research Laboratory, Sandia Laboratories, Livermore, CA

    International Nuclear Information System (INIS)

    Wall, W.R.; Hafner, R.S.; Westfall, D.L.; Ristau, R.D.

    1978-11-01

    Automated tritium monitoring is now in use at the Tritium Research Laboratory (TRL). Betatec 100 tritium monitors, along with several Sandia-designed accessories, have been combined with a PDP 11/40 computer to automatically read and record tritium concentrations of room air, containment, and cleanup systems. Each individual monitoring system, in addition to a local display in the area of interest, has a visible/audible display in the control room. Each system is then channeled into the PDP 11/40 computer, providing immediate assessment of the status of the entire laboratory from a central location. Measurement capability ranges from μCi/m 3 levels for room air monitoring to kCi/m 3 levels for glove box and cleanup systems monitoring. In this report the overall monitoring system and its capabilities are discussed, with detailed descriptions given of monitors and their components

  19. Laboratory and field testing results of the LMT/GTM primary surface actuators

    Science.gov (United States)

    Smith, David R.; Souccar, Kamal; Montalvo, Gabriela; Arteaga Magaña, César; Hernández Rebollar, José Luis; Olmos Tapia, Arak; Gallieni, Daniele; Lazzarini, Paolo; Fumi, Pierluigi; Anaclerio, Enzo

    2016-07-01

    With the final installation of the two outermost rings of the primary surface of the Large Millimeter Telescope/ Gran Telescopio Milimétrico (LMT/GTM), the project is also upgrading the primary surface actuators. There are commercial actuators that can approach the required operational accuracy and stroke, but the combination of the size and load requirements ultimately required a customized design. The new actuators fit within the volume constraints imposed by the tighter interior angles in the outer rings and are designed to support the operational and survival loading conditions even for the largest surface segments. Laboratory testing confirmed that the actuators should meet the precision, repeatability, load, and lifetime requirements. However, the LMT/GTM is at a particularly difficult site for electromechanical systems. The high altitude has the usual effect of reducing cooling effectiveness for the drives and motors, and the ambient temperature hovers near freezing. Since there is a significant amount of precipitation during some times of the year, there are frequent freeze/thaw cycles. The constant formation and either sublimation or melting of ice, along with the associated high humidity, has been a challenge for the environmental protection of many devices at the LMT/GTM. Because there are a total of 720 primary surface actuators in the system, it is particularly important that the actuators, their local drive control boxes, and their cable connections be able to meet its specifications even under the site conditions. To confirm the suitability of the actuators, the LMT/GTM procured an initial set of sixteen actuators for testing at the site. After laboratory testing, the actuators were installed into the outer two rings of the telescope and cycled during the early winter months of the 2015-16 scientific observing season. Because of the continuing installation activities in these two rings, they are not illuminated by the receivers, so field testing

  20. Incorporating Systems Thinking in Traditional Geoscience Curriculum: A Laboratory Assignment

    Science.gov (United States)

    Mitra, R.; Cook, G. W.; McNeal, K.

    2014-12-01

    The role of systems thinking in understanding climate change has gained credence over the years. A key concept of systems thinking, namely, stock and flow, deals with the accumulation of any stock in a system over time, such as carbon dioxide in the atmosphere. Several studies have shown that people find it difficult to comprehend the dynamics of such a system. In this study, we design a laboratory module for an introductory earth science course aimed at improving students' understanding of stock-flow concepts. We have structured the laboratory exercise after Bloom's taxonomic principles to include comprehension, application, analysis, synthesis and evaluation. Additionally, we have blended metacognition and self-correction by asking the students to reflect on their learning and by providing cues that enable them to rectify and learn from their own mistakes. We will discuss learning gains for the class, the efficacy of using such scaffolding for laboratory modules and the role of systems thinking in understanding climate change.

  1. The monitoring system of the Tritium Research Laboratory, Sandia Laboratories, Livermore, California

    International Nuclear Information System (INIS)

    Hafner, R.S.; Westfall, D.L.; Ristau, R.D.

    1978-01-01

    Computerized tritium monitoring is now in use at the Tritium Research Laboratory (TRL). Betatec 100 tritium monitors, along with several Sandia designed accessories, have been combined with a PDP 11/40 computer to provide maximum personnel and environmental protection. Each individual monitoring system, in addition to a local display in the area of interest, has a visual/audible display in the control room. Each system is then channeled into the PDP 11/40 computer, providing immediate assessment of the status of the entire laboratory from a central location. Measurement capability ranges from uCi/m 3 levels for room air monitoring to KCi/m 3 levels for glove box and process system monitoring. The overall monitoring system and its capabilities will be presented

  2. Laboratory Activity Worksheet to Train High Order Thinking Skill of Student on Surface Chemistry Lecture

    Science.gov (United States)

    Yonata, B.; Nasrudin, H.

    2018-01-01

    A worksheet has to be a set with activity which is help students to arrange their own experiments. For this reason, this research is focused on how to train students’ higher order thinking skills in laboratory activity by developing laboratory activity worksheet on surface chemistry lecture. To ensure that the laboratory activity worksheet already contains aspects of the higher order thinking skill, it requires theoretical and empirical validation. From the data analysis results, it shows that the developed worksheet worth to use. The worksheet is worthy of theoretical and empirical feasibility. This conclusion is based on the findings: 1) Assessment from the validators about the theoretical feasibility aspects in the category is very feasible with an assessment range of 95.24% to 97.92%. 2) students’ higher thinking skill from N Gain values ranges from 0.50 (enough) to 1.00 (high) so it can be concluded that the laboratory activity worksheet on surface chemistry lecture is empirical in terms of worth. The empirical feasibility is supported by the responses of the students in very reasonable categories. It is expected that the laboratory activity worksheet on surface chemistry lecture can train students’ high order thinking skills for students who program surface chemistry lecture.

  3. Wet chemical analysis with a laboratory robotic system

    International Nuclear Information System (INIS)

    Burkett, S.D.; Dyches, G.M.; Spencer, W.A.

    1984-01-01

    Emphasis on laboratory automation has increased in recent years. The desire to improve analytical reliability, increase productivity, and reduce exposure of personnel to hazardous materials has been fundamental to this increase. The Savannah River Laboratory (SRL) performs research and development on nuclear materials. Development of methods to increase efficiency and safety and to reduce exposure of personnel to radioactive materials is an ongoing process at our site. Robotic systems offer a potentially attractive way to achieve these goals

  4. BIOPLUS: An eclectic laboratory information management system for the ORNL Radiobioassay Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Ferguson, R.L.; Hwang, H.L.; Bishop, C.P.; Blair, R.L.; Cornett, R.L.; Gonzalez, B.D.; Hotchandani, M.; Keaton, J.A.; Miller, J.L.; Myers, R.D.; Ohnesorge, M.J.; Thein, M.

    1992-12-31

    Data management activities in analytical laboratories can include sample scheduling, logging, and tracking, as well as results collection and reporting. In the Radiobioassay Laboratory (RBL) such activities were formerly accomplished by entering data in log books and on forms followed by manual entry of data into a computer database. As sample load has increased and further emphasis has been placed on improving efficiency and on error reduction, it has become worthwhile to automate the laboratory`s information management. In addition, a Bioassay Data Management System (BDMS) has developed for use by all five of the DOE sites managed by Martin Marietta Energy Systems in order to centralize bioassay data management for internal dosimetry purposes. BIOPLUS, the LIMS described in this paper, provides an interface with BDMS and automates RBL information management to a large extent. The system provides for downloading personnel data from a central computer, logging in samples, and bar-code sample tracking, as well as recording, reporting, archiving, and trending of analysis results. Sketches of the hardware and software are presented along with some details of the instrument interface modules.

  5. Improving performance in the ED through laboratory information exchange systems.

    Science.gov (United States)

    Raymond, Louis; Paré, Guy; Maillet, Éric; Ortiz de Guinea, Ana; Trudel, Marie-Claude; Marsan, Josianne

    2018-03-12

    The accessibility of laboratory test results is crucial to the performance of emergency departments and to the safety of patients. This study aims to develop a better understanding of which laboratory information exchange (LIE) systems emergency care physicians (ECPs) are using to consult their patients' laboratory test results and which benefits they derive from such use. A survey of 163 (36%) ECPs in Quebec was conducted in collaboration with the Quebec's Department of Health and Social Services. Descriptive statistics, chi-square tests, cluster analyses, and ANOVAs were conducted. The great majority of respondents indicated that they use several LIE systems including interoperable electronic health record (iEHR) systems, laboratory results viewers (LRVs), and emergency department information systems (EDIS) to consult their patients' laboratory results. Three distinct profiles of LIE users were observed. The extent of LIE usage was found to be primarily determined by the functional design differences between LIE systems available in the EDs. Our findings also indicate that the more widespread LIE usage, the higher the perceived benefits. More specifically, physicians who make extensive use of iEHR systems and LRVs obtain the widest range of benefits in terms of efficiency, quality, and safety of emergency care. Extensive use of LIE systems allows ECPs to better determine and monitor the health status of their patients, verify their diagnostic assumptions, and apply evidence-based practices in laboratory medicine. But for such benefits to be possible, ECPs must be provided with LIE systems that produce accurate, up-to-date, complete, and easy-to-interpret information.

  6. Exploration technology surface systems: Surface Habitats And Construction (SHAC)

    Science.gov (United States)

    Hirschbein, Murray

    1991-01-01

    The objectives of exploration technology program - surface systems are: (1) to develop technology emplace and to build an outpost on the moon and Mars; and (2) to develop concepts for permanent habitats and enclosures on the Moon and Mars.

  7. Sandia National Laboratories, California Environmental Management System program manual

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, Barbara L.

    2014-04-01

    The Sandia National Laboratories, California (SNL/CA) Environmental Management System (EMS) Program Manual documents the elements of the site EMS Program. The SNL/CA EMS Program conforms to the International Standard on Environmental Management Systems, ISO 14001:2004 and Department of Energy (DOE) Order 436.1.

  8. Sandia National Laboratories, California Environmental Management System program manual.

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, Barbara L.

    2013-04-01

    The Sandia National Laboratories, California (SNL/CA) Environmental Management System (EMS) Program Manual documents the elements of the site EMS Program. The SNL/CA EMS Program conforms to the International Standard on Environmental Management Systems, ISO 14001:2004 and Department of Energy (DOE) Order 436.1.

  9. Integrated management system best practices in radioecological laboratories

    International Nuclear Information System (INIS)

    Carvalho, Claudia Aparecida Zerbinatti de

    2009-01-01

    This paper presents a Master dissertation advancements with the target of studying the best practices, in order to give support to an IMS conceptual model ?Integrated Management System (quality, environment, work safety and health), applied to radioecological laboratories. The planning of the proposed research comprises the following stages: first stage - the bibliographic and documental survey in IMS; a survey and study of the applied standards (QMS NBR ISO 9000 (2005), NBR ISO 9001 (2008), NBR ISO 9004 (2000), EMS 14001(2004) and OHSMS OHSAS 18001 (2007) and OHSAS 18002 (2008)); identification and characterization in radioecological laboratories processes; a methodological study of better practices and benchmarking is carried out. In the second stage of the research, the development of a case study is forecast (qualitative research, with electronic questionnaires and personal interviews, when possible), preceded by a survey and selection of international and national radioecological laboratories to be studied and, in sequence, these laboratories should be contacted and agree to participate in the research; in a third stage, the construction of a matrix of better practices, which incur in the results able to subside an IMS conceptual model proposition for radioecological laboratories; the fourth and last stage of the research comprises the construction of a conceptual proposal of an IMS structure for radioecological laboratories. The first stage of the research results are presented concisely, as well as a preliminary selection of laboratories to be studied. (author)

  10. Integrated management system best practices in radioecological laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Claudia Aparecida Zerbinatti de [Centro Tecnologico da Marinha em Sao Paulo (CTMSP), SP (Brazil). Dept. da Qualidade], e-mail: clau.zerbina@gmail.com; Zouain, Desiree Moraes [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)], e-mail: dmzouain@ipen.br

    2009-07-01

    This paper presents a Master dissertation advancements with the target of studying the best practices, in order to give support to an IMS conceptual model ?Integrated Management System (quality, environment, work safety and health), applied to radioecological laboratories. The planning of the proposed research comprises the following stages: first stage - the bibliographic and documental survey in IMS; a survey and study of the applied standards (QMS NBR ISO 9000 (2005), NBR ISO 9001 (2008), NBR ISO 9004 (2000), EMS 14001(2004) and OHSMS OHSAS 18001 (2007) and OHSAS 18002 (2008)); identification and characterization in radioecological laboratories processes; a methodological study of better practices and benchmarking is carried out. In the second stage of the research, the development of a case study is forecast (qualitative research, with electronic questionnaires and personal interviews, when possible), preceded by a survey and selection of international and national radioecological laboratories to be studied and, in sequence, these laboratories should be contacted and agree to participate in the research; in a third stage, the construction of a matrix of better practices, which incur in the results able to subside an IMS conceptual model proposition for radioecological laboratories; the fourth and last stage of the research comprises the construction of a conceptual proposal of an IMS structure for radioecological laboratories. The first stage of the research results are presented concisely, as well as a preliminary selection of laboratories to be studied. (author)

  11. Laboratory Information System – Where are we Today?

    Directory of Open Access Journals (Sweden)

    Lukić Vera

    2017-09-01

    Full Text Available Wider implementation of laboratory information systems (LIS in clinical laboratories in Serbia has been initiated ten years ago. The first LIS in the Railway Health Care Institute has been implemented nine years ago. Before the LIS was initiated, manual admission procedures limited daily output of patients. Moreover, manual entering of patients data and ordering tests on analyzers was problematic and time consuming. After completing tests, laboratory personnel had to write results in patient register (with potential errors and provide invoices for health insurance organisation. First LIS brought forward some advantages with regards to these obstacles, but it also showed various weaknesses. These can be summarised in rigidity of system and inability to fulfil user expectation. After 4 years of use, we replaced this system with another LIS. Hence, the main aim of this paper is to evaluate advant ages of using LIS in laboratory of the Railway Health Care Institute and also to discuss further possibilities for its application. After implementing LIS, admission procedure has proven to be much faster. LIS enabled electronic requests, barcoded specimens prevent identification errors, bidirectional interface replaces redundant data entry steps, QC data are transferred automatically, results are electronically validated and automatically archived in data base, billing information is transferred electronically, and more. We also use some advanced options, like delta check, HIL feature, quality indicators and various types of reports. All steps in total testing process are drastically improved after the implementation of LIS, which had a positive impact on the quality of issued laboratory results. However, we expect development of some new features in the future, for example auto-verification and inventory management. On the example of the laboratory of the Railway Health Care Institute, we show that it is crucial that laboratory specialists have the main

  12. Installation of Computerized Procedure System and Advanced Alarm System in the Human Systems Simulation Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Le Blanc, Katya Lee [Idaho National Lab. (INL), Idaho Falls, ID (United States); Spielman, Zachary Alexander [Idaho National Lab. (INL), Idaho Falls, ID (United States); Rice, Brandon Charles [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-04-01

    This report describes the installation of two advanced control room technologies, an advanced alarm system and a computerized procedure system, into the Human Systems Simulation Laboratory (HSSL). Installation of these technologies enables future phases of this research by providing a platform to systematically evaluate the effect of these technologies on operator and plant performance.

  13. Installation of Computerized Procedure System and Advanced Alarm System in the Human Systems Simulation Laboratory

    International Nuclear Information System (INIS)

    Le Blanc, Katya Lee; Spielman, Zachary Alexander; Rice, Brandon Charles

    2016-01-01

    This report describes the installation of two advanced control room technologies, an advanced alarm system and a computerized procedure system, into the Human Systems Simulation Laboratory (HSSL). Installation of these technologies enables future phases of this research by providing a platform to systematically evaluate the effect of these technologies on operator and plant performance.

  14. Laboratory Information Management Systems for Forensic Laboratories: A White Paper for Directors and Decision Makers

    Energy Technology Data Exchange (ETDEWEB)

    Anthony Hendrickson; Brian Mennecke; Kevin Scheibe; Anthony Townsend

    2005-10-01

    Modern, forensics laboratories need Laboratory Information Management Systems (LIMS) implementations that allow the lab to track evidentiary items through their examination lifecycle and also serve all pertinent laboratory personnel. The research presented here presents LIMS core requirements as viewed by respondents serving in different forensic laboratory capacities as well as different forensic laboratory environments. A product-development methodology was employed to evaluate the relative value of the key features that constitute a LIMS, in order to develop a set of relative values for these features and the specifics of their implementation. In addition to the results of the product development analysis, this paper also provides an extensive review of LIMS and provides an overview of the preparation and planning process for the successful upgrade or implementation of a LIMS. Analysis of the data indicate that the relative value of LIMS components are viewed differently depending upon respondents' job roles (i.e., evidence technicians, scientists, and lab management), as well as by laboratory size. Specifically, the data show that: (1) Evidence technicians place the most value on chain of evidence capabilities and on chain of custody tracking; (2) Scientists generally place greatest value on report writing and generation, and on tracking daughter evidence that develops during their analyses; (3) Lab. Managers place the greatest value on chain of custody, daughter evidence, and not surprisingly, management reporting capabilities; and (4) Lab size affects LIMS preference in that, while all labs place daughter evidence tracking, chain of custody, and management and analyst report generation as their top three priorities, the order of this prioritization is size dependent.

  15. Culturing Security System of Chemical Laboratory in Indonesia

    Directory of Open Access Journals (Sweden)

    Eka Dian Pusfitasari

    2017-04-01

    Full Text Available Indonesia has experiences on the lack of chemical security such as: a number of bombing terrors and hazardous chemicals found in food. Bomb used in terror is a homemade bomb made from chemicals which are widely spread in the research laboratories such as a mixture of pottasium chlorate, sulphur, and alumunium. Therefore, security of chemicals should be implemented to avoid the misused of the chemicals. Although it has experienced many cases of the misuse of chemicals, and many regulations and seminars related to chemical security have been held, but the implementation of chemical security is still a new thing for Indonesian citizens. The evident is coming from the interviews conducted in this study. Questions asked in this interview/survey included: the implementation of chemical safety and chemical security in laboratory; chemical inventory system and its regulation; and training needed for chemical security implementation. Respondents were basically a researcher from Government Research Institutes, University laboratories, senior high school laboratories, and service laboratories were still ambiguous in distinguishing chemical safety and chemical security. Because of this condition, most Indonesia chemical laboratories did not totally apply chemical security system. Education is very important step to raise people awareness and address this problem. Law and regulations should be sustained by all laboratory personnel activities to avoid chemical diversion to be used for harming people and environment. The Indonesia Government could also develop practical guidelines and standards to be applied to all chemical laboratories in Indonesia. These acts can help Government’s efforts to promote chemical security best practices which usually conducted by doing seminars and workshop.

  16. Brookhaven National Laboratory's multiparticle spectrometer drift chamber system

    International Nuclear Information System (INIS)

    Etkin, A.; Kramer, M.A.

    1979-01-01

    A system of drift chambers is being built to replace the present spark chambers in the Brookhaven National Laboratory's Multiparticle Spectrometer. This system will handle a beam of approx. 3 million particles per second and have a resolution of 200 μm. A summary of the status of the chambers and the custom integrated circuits is presented. The data acquisition system is described. Prototype chambers have been built and tested with results that are consistent with the expected chamber properties

  17. Surface water data at Los Alamos National Laboratory: 2008 water year

    Energy Technology Data Exchange (ETDEWEB)

    Ortiz, David; Cata, Betsy; Kuyumjian, Gregory

    2009-09-01

    The principal investigators collected and computed surface water discharge data from 69 stream-gage stations that cover most of Los Alamos National Laboratory and one at Bandelier National Monument. Also included are discharge data from three springs— two that flow into Cañon de Valle and one that flows into Water Canyon.

  18. Surface Water Data at Los Alamos National Laboratory 2006 Water Year

    Energy Technology Data Exchange (ETDEWEB)

    R.P. Romero, D. Ortiz, G. Kuyumjian

    2007-08-01

    The principal investigators collected and computed surface water discharge data from 44 stream-gaging stations that cover most of Los Alamos National Laboratory and one at Bandelier National Monument. Also included are discharge data from three springs--two that flow into Canon de Valle and one that flows into Water Canyon--and peak flow data for 44 stations.

  19. Shielding concepts for low-background proportional counter arrays in surface laboratories

    International Nuclear Information System (INIS)

    Aalseth, C.E.; Humble, P.H.; Mace, E.K.; Orrell, J.L.; Seifert, A.; Williams, R.M.

    2016-01-01

    Development of ultra low background gas proportional counters has made the contribution from naturally occurring radioactive isotopes – primarily α and β activity in the uranium and thorium decay chains – inconsequential to instrumental sensitivity levels when measurements are performed in above ground surface laboratories. Simple lead shielding is enough to mitigate against gamma rays as gas proportional counters are already relatively insensitive to naturally occurring gamma radiation. The dominant background in these surface laboratory measurements using ultra low background gas proportional counters is due to cosmic ray generated muons, neutrons, and protons. Studies of measurements with ultra low background gas proportional counters in surface and underground laboratories as well as radiation transport Monte Carlo simulations suggest a preferred conceptual design to achieve the highest possible sensitivity from an array of low background gas proportional counters when operated in a surface laboratory. The basis for a low background gas proportional counter array and the preferred shielding configuration is reported, especially in relation to measurements of radioactive gases having low energy decays such as 37 Ar. - Highlights: • Optimization of a cosmic ray shield to measure environmental radioactive gases. • Proportional counter sensitivity may reach ambient environmental 37 Ar concentrations. • Variable length counter method evaluated for low concentration absolute gas counting. • Feasibility of several hour duration preparation of gas samples for 37 Ar measurement.

  20. BIOPLUS: An eclectic laboratory information management system for the ORNL Radiobioassay Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Ferguson, R.L.; Hwang, H.L.; Bishop, C.P.; Blair, R.L.; Cornett, R.L.; Gonzalez, B.D.; Hotchandani, M.; Keaton, J.A.; Miller, J.L.; Myers, R.D.; Ohnesorge, M.J.; Thein, M.

    1992-01-01

    Data management activities in analytical laboratories can include sample scheduling, logging, and tracking, as well as results collection and reporting. In the Radiobioassay Laboratory (RBL) such activities were formerly accomplished by entering data in log books and on forms followed by manual entry of data into a computer database. As sample load has increased and further emphasis has been placed on improving efficiency and on error reduction, it has become worthwhile to automate the laboratory's information management. In addition, a Bioassay Data Management System (BDMS) has developed for use by all five of the DOE sites managed by Martin Marietta Energy Systems in order to centralize bioassay data management for internal dosimetry purposes. BIOPLUS, the LIMS described in this paper, provides an interface with BDMS and automates RBL information management to a large extent. The system provides for downloading personnel data from a central computer, logging in samples, and bar-code sample tracking, as well as recording, reporting, archiving, and trending of analysis results. Sketches of the hardware and software are presented along with some details of the instrument interface modules.

  1. ELAN - expert system supported information and management system for analytical laboratories

    International Nuclear Information System (INIS)

    Jaeschke, A.; Orth, H.; Zilly, G.

    1990-08-01

    The demand for high efficiency and short response time calls for the use of computer support in chemico-analytical laboratories. This is usually achieved by laboratory information and management systems covering the three levels of analytical instrument automation, laboratory operation support and laboratory management. The management component of the systems implemented up to now suffers from a lack of flexibility as far as unforeseen analytical investigations outside the laboratory routine work are concerned. Another drawback is the lack of adaptability with respect to structural changes in laboratory organization. It can be eliminated by the application of expert system structures and methods for the implementation of this system level. The ELAN laboratory information and management system has been developed on the basis of this concept. (orig.) [de

  2. Building a Laboratory Information Management System Using Windows4GL

    International Nuclear Information System (INIS)

    Pickens, M.A.; Shaieb, M.R.

    1996-05-01

    The system discussed is currently implemented at LLNL in the Environmental Services program which operates out of the Chemistry ampersand Materials Science (C ampersand MS) directorate. Responsibility is to provide the C ampersand MS Environmental Services (CES) program with an enterprise-wide information system which will aid CES. The specific portion of the information system is the Sample Tracking, Analysis and Reporting System (STARS). Since CES was formed by merging two analytical laboratory organizations in May 1995, a new Laboratory Information Management System (LIMS) had to be developed. The development of a LIMS in Windows4GL was found to be satisfactory. The product STARS was well received by the user community, and it has improved business practices and efficiency in CES. The CES management staff has seen increased personnel productivity since STARS was release. We look forward to upgrading to CA-OpenROAD and taking advantage of its many improved and innovative features to further enhance STARS

  3. Building a Laboratory Information Management System Using Windows4GL

    Energy Technology Data Exchange (ETDEWEB)

    Pickens, M.A.; Shaieb, M.R.

    1996-05-01

    The system discussed is currently implemented at LLNL in the Environmental Services program which operates out of the Chemistry & Materials Science (C&MS) directorate. Responsibility is to provide the C&MS Environmental Services (CES) program with an enterprise-wide information system which will aid CES. The specific portion of the information system is the Sample Tracking, Analysis and Reporting System (STARS). Since CES was formed by merging two analytical laboratory organizations in May 1995, a new Laboratory Information Management System (LIMS) had to be developed. The development of a LIMS in Windows4GL was found to be satisfactory. The product STARS was well received by the user community, and it has improved business practices and efficiency in CES. The CES management staff has seen increased personnel productivity since STARS was release. We look forward to upgrading to CA-OpenROAD and taking advantage of its many improved and innovative features to further enhance STARS.

  4. System Quality Management in Software Testing Laboratory that Chooses Accreditation

    Directory of Open Access Journals (Sweden)

    Yanet Brito R.

    2013-12-01

    Full Text Available The evaluation of software products will reach full maturity when executed by the scheme and provides third party certification. For the validity of the certification, the independent laboratory must be accredited for that function, using internationally recognized standards. This brings with it a challenge for the Industrial Laboratory Testing Software (LIPS, responsible for testing the products developed in Cuban Software Industry, define strategies that will permit it to offer services with a high level of quality. Therefore it is necessary to establish a system of quality management according to NC-ISO/IEC 17025: 2006 to continuously improve the operational capacity and technical competence of the laboratory, with a view to future accreditation of tests performed. This article discusses the process defined in the LIPS for the implementation of a Management System of Quality, from the current standards and trends, as a necessary step to opt for the accreditation of the tests performed.

  5. AUTOMATED REMOTE MANAGEMENT AND CONTROL SYSTEM OF THE LABORATORY EQUIPMENT

    Directory of Open Access Journals (Sweden)

    V. I. Freyman

    2017-01-01

    Full Text Available The paper deals with the hardware and software implementation of automated remote management system of laboratory equipment for studying fundamentals of electronics and circuit technology. This system gives the possibility to create the virtual model of a real stand. The original software has enabled to compare information from the memory of microcontroller keeping in laboratory stands with etalon model, and reveal discrepancies of set connections and template data. Graphical interface allows for operation control of students and correction of studying process. Automation of configuring and the following checking procedures has accelerated the work and decreased error frequency, made it possible to improve the quality of learning, increase efficiency of laboratory researches and control accuracy, intensify the check procedure and use self-checking in case of independent execution of tasks.

  6. Laboratory experiments to investigate radionuclide enrichment in the sea-surface microlayer

    International Nuclear Information System (INIS)

    Hickmott, S.J.B.

    1982-02-01

    Samples of simulated seawater, and seawater from the Irish Sea, were contained in a plastic tank in the laboratory, and bubbles were passed through them to burst at the water surface. The emitted jet droplets, as representing the surface microlayer, were collected on filter papers. Such measurements are easier to perform than similar measurements at sea, and the lack of waves enables greater collection efficiencies to be obtained. The droplet samples were analysed for stable Na, 137 Cs and actinides, and compared with the concentrations in the bulk tank water, in order to examine possible concentration factors for radionuclides in the surface microlayer. (author)

  7. Integrated management system best practices in radioecological laboratories

    International Nuclear Information System (INIS)

    Carvalho, Claudia Aparecida Zerbinatti de

    2010-01-01

    The research aims to study the best practices to support a conceptual proposal for IMS - Integrated Management System (quality, environment, safety and health) applicable to Radioecology laboratories. The research design is organized into the following steps: in a first step, it was developed the bibliographic and documentary research in IMS, survey and study of standards (QMS ISO 9000 (2005), ISO 9001 (2008), ISO 9004 (2000), EMS ISO 14001 (2004) and OHSMS OHSAS 18001 (2007) and OHSAS 18002 (2008)), identification and characterization of processes in Radioecology Laboratories and study of best practices methodology and benchmarking; in the second stage of the research it was developed a case study (qualitative research, with questionnaires via e-mail and interviews, when possible), preceded by a survey and selection of international and national radioecology laboratories and then these laboratories were contacted and some of them agreed to participate in this research; in the third stage of the research it was built the framework of best practices that showed results that could support the conceptual proposal for the IMS Radioecology Laboratory; the fourth and final stage of research consisted in the construction of the proposed conceptual framework of SGI for Radioecology Laboratory, being then achieved the initial objective of the research. (author)

  8. The evolution of a LIMS [laboratory information management system

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Changes in the world and United Kingdom markets for nuclear fuels during the 1990s have prompted British Nuclear Fuels (BNFL) to maximise cost effectiveness in its Chemical and Metallurgical Services department. A laboratory information management system (LIMS) was introduced in order to keep records of analytical techniques and equipment up to date by coordinating various computer systems. Wherever possible automated systems have replaced traditional, labour intensive techniques. So successful has the LIMS system been, that the team now hopes to expand into expert systems. (UK)

  9. A Computerized Clinical Support System and Psychological Laboratory.

    Science.gov (United States)

    Cassel, Russell N.

    1978-01-01

    Advocating "holistic" medicine, this article details the benefits to be derived from using a computerized clinical support system in a psychological laboratory focusing on internal healing where the client/patient becomes a committed partner utilizing biofeedback equipment, gaming, and simulation to achieve self-understanding and…

  10. Sandia National Laboratories photovoltaic balance of systems program

    Science.gov (United States)

    Bonn, Russell H.; Ginn, Jerry; Hund, Tom; Gonzalez, Sigfredo; Ralph, Mark; Strommen, Roger

    1999-03-01

    The Sandia National Laboratories photovoltaic balance of system (BOS) program is sponsored by the Department of Energy to increase the reliability and lower the cost of BOS components. Efforts for FY1998 are discussed. Principal efforts include a quality program for inverter manufacturers, a grid-tied anti-islanding program, development of a hybrid inverter, hardware benchmarking program, and a battery evaluation program.

  11. A laboratory information management system for DNA barcoding workflows

    NARCIS (Netherlands)

    Vu, D.; Eberhardt, U.; Szöke, S.; Groenewald, M.; Robert, V.

    2012-01-01

    This paper presents a laboratory information management system for DNA sequences (LIMS) created and based on the needs of a DNA barcoding project at the CBS-KNAW Fungal Biodiversity Centre (Utrecht, the Netherlands). DNA barcoding is a global initiative for species identification through simple DNA

  12. A laboratory goniometer system for measuring reflectance and emittance anisotropy

    NARCIS (Netherlands)

    Roosjen, P.P.J.; Clevers, J.G.P.W.; Bartholomeus, H.; Schaepman, M.E.; Schaepman-Strub, G.; Jalink, H.; Schoor, van der R.; Jong, de A.

    2012-01-01

    In this paper, a laboratory goniometer system for performing multi-angular measurements under controlled illumination conditions is described. A commercially available robotic arm enables the acquisition of a large number of measurements over the full hemisphere within a short time span making it

  13. Onsite Distributed Generation Systems For Laboratories, Laboratories for the 21st Century: Best Practices (Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    2011-09-01

    This guide provides general information on implementing onsite distributed generation systems in laboratory environments. Specific technology applications, general performance information, and cost data are provided to educate and encourage laboratory energy managers to consider onsite power generation or combined heat and power (CHP) systems for their facilities. After conducting an initial screening, energy managers are encouraged to conduct a detailed feasibility study with actual cost and performance data for technologies that look promising. Onsite distributed generation systems are small, modular, decentralized, grid-connected, or off-grid energy systems. These systems are located at or near the place where the energy is used. These systems are also known as distributed energy or distributed power systems. DG technologies are generally considered those that produce less than 20 megawatts (MW) of power. A number of technologies can be applied as effective onsite DG systems, including: (1) Diesel, natural gas, and dual-fuel reciprocating engines; (2) Combustion turbines and steam turbines; (3) Fuel cells; (4) Biomass heating; (5) Biomass combined heat and power; (6) Photovoltaics; and (7) Wind turbines. These systems can provide a number of potential benefits to an individual laboratory facility or campus, including: (1) High-quality, reliable, and potentially dispatchable power; (2) Low-cost energy and long-term utility cost assurance, especially where electricity and/or fuel costs are high; (3) Significantly reduced greenhouse gas (GHG) emissions. Typical CHP plants reduce onsite GHG by 40 to 60 percent; (4) Peak demand shaving where demand costs are high; (5) CHP where thermal energy can be used in addition to electricity; (6) The ability to meet standby power needs, especially where utility-supplied power is interrupted frequently or for long periods and where standby power is required for safety or emergencies; and (7) Use for standalone or off

  14. Power System for Venus Surface Exploration

    Science.gov (United States)

    Landis, Geoffrey A.; Mellott, Kenneth

    2002-01-01

    A radioisotope power and cooling system is designed to provide electrical power for a probe operating on the surface of Venus. Most foreseeable electronics devices and sensors cannot operate at the 450 C ambient surface temperature of Venus. Because the mission duration is substantially long and the use of thermal mass to maintain an operable temperature range is likely impractical, some type of active refrigeration may be required to keep electronic components at a temperature below ambient. The fundamental cooling parameters are the cold sink temperature, the hot sink temperature, and the amount of heat to be removed. In this instance, it is anticipated that electronics would have a nominal operating temperature of 300 C. Due to the highly thermal convective nature of the high-density (90 bar CO2) atmosphere, the hot sink temperature was assumed to be 50 C, which provided a 500 C temperature of the cooler's heat rejecter to the ambient atmosphere. The majority of the heat load on the cooler is from the high temperature ambient surface environment on Venus, with a small contribution of heat generation from electronics and sensors. Both thermoelectric (RTG) and dynamic power conversion systems were analyzed, based on use of a standard isotope (General-purpose heat source, or GPHS) brick. For the radioisotope Stirling power converter configuration designed, the Sage model predicts a thermodynamic power output capacity of 478.1 watts, which slightly exceeds the required 469.1 watts. The hot sink temperature is 1200 C, and the cold sink temperature is 500 C. The required heat input is 1740 watts. This gives a thermodynamic efficiency of 27.48 %. It is estimated that the mechanical efficiency of the power converter design is on the order of 85 %, based on experimental measurements taken from 500-watt power class, laboratory-tested Stirling engines. The overall efficiency is calculated to be 23.36 %. The mass of the power converter is estimated at approximately 21.6 kg

  15. Experiential learning in control systems laboratories and engineering project management

    Science.gov (United States)

    Reck, Rebecca Marie

    Experiential learning is a process by which a student creates knowledge through the insights gained from an experience. Kolb's model of experiential learning is a cycle of four modes: (1) concrete experience, (2) reflective observation, (3) abstract conceptualization, and (4) active experimentation. His model is used in each of the three studies presented in this dissertation. Laboratories are a popular way to apply the experiential learning modes in STEM courses. Laboratory kits allow students to take home laboratory equipment to complete experiments on their own time. Although students like laboratory kits, no previous studies compared student learning outcomes on assignments using laboratory kits with existing laboratory equipment. In this study, we examined the similarities and differences between the experiences of students who used a portable laboratory kit and students who used the traditional equipment. During the 2014- 2015 academic year, we conducted a quasi-experiment to compare students' achievement of learning outcomes and their experiences in the instructional laboratory for an introductory control systems course. Half of the laboratory sections in each semester used the existing equipment, while the other sections used a new kit. We collected both quantitative data and qualitative data. We did not identify any major differences in the student experience based on the equipment they used. Course objectives, like research objectives and product requirements, help provide clarity and direction for faculty and students. Unfortunately, course and laboratory objectives are not always clearly stated. Without a clear set of objectives, it can be hard to design a learning experience and determine whether students are achieving the intended outcomes of the course or laboratory. In this study, I identified a common set of laboratory objectives, concepts, and components of a laboratory apparatus for undergraduate control systems laboratories. During the summer of

  16. SSCL magnet systems quality program implementation for laboratory and industry

    International Nuclear Information System (INIS)

    Warner, D.G.; Bever, D.L.

    1992-01-01

    The development and delivery of reliable and producible magnets for the Superconducting Super Collider Laboratory (SSCL) require the teamwork of a large and diverse workforce composed of personnel with backgrounds in laboratory research, defense, and energy. The SSCL Magnet Quality Program is being implemented with focus on three definitive objectives: (1) communication of requirements, (2) teamwork, and (3) verification. Examination of the SSCL Magnet Systems Division's (MSD) current and planned approach to implementation of the SSCL Magnet Quality Program utilizing these objectives is discussed

  17. Treatment systems for liquid wastes generated in chemical analysis laboratories

    International Nuclear Information System (INIS)

    Linda Berrio; Oscar Beltran; Edison Agudelo; Santiago Cardona

    2012-01-01

    Nowadays, handling of liquid wastes from chemical analysis laboratories is posing problems to different public and private organizations because of its requirements of an integrated management. This article reviews various treatment technologies and its removal efficiencies in order to establish criteria for selecting the system and the appropriate variables to achieve research objectives as well as environmental sustainability. Review begins with a description of the problem and continues with the study of treatments for laboratory wastes. These technologies are segregated into physicochemical and biological treatments that comprise a variety of processes, some of which are considered in this review.

  18. Using the Human Systems Simulation Laboratory at Idaho National Laboratory for Safety Focused Research

    Energy Technology Data Exchange (ETDEWEB)

    Joe, Jeffrey .C; Boring, Ronald L.

    2016-07-01

    Under the United States (U.S.) Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) program, researchers at Idaho National Laboratory (INL) have been using the Human Systems Simulation Laboratory (HSSL) to conduct critical safety focused Human Factors research and development (R&D) for the nuclear industry. The LWRS program has the overall objective to develop the scientific basis to extend existing nuclear power plant (NPP) operating life beyond the current 60-year licensing period and to ensure their long-term reliability, productivity, safety, and security. One focus area for LWRS is the NPP main control room (MCR), because many of the instrumentation and control (I&C) system technologies installed in the MCR, while highly reliable and safe, are now difficult to replace and are therefore limiting the operating life of the NPP. This paper describes how INL researchers use the HSSL to conduct Human Factors R&D on modernizing or upgrading these I&C systems in a step-wise manner, and how the HSSL has addressed a significant gap in how to upgrade systems and technologies that are built to last, and therefore require careful integration of analog and new advanced digital technologies.

  19. Retrofitting Combined Space and Water Heating Systems. Laboratory Tests

    Energy Technology Data Exchange (ETDEWEB)

    Schoenbauer, B. [NorthernStar Building America Partnership, St. Paul, MN (United States); Bohac, D. [NorthernStar Building America Partnership, St. Paul, MN (United States); Huelman, P. [NorthernStar Building America Partnership, St. Paul, MN (United States); Olsen, R. [NorthernStar Building America Partnership, St. Paul, MN (United States); Hewett, M. [NorthernStar Building America Partnership, St. Paul, MN (United States)

    2012-10-01

    Better insulated and tighter homes can often use a single heating plant for both space and domestic water heating. These systems, called dual integrated appliances (DIA) or combination systems, can operate at high efficiency and eliminate combustion safety issues associated by using a condensing, sealed combustion heating plant. Funds were received to install 400 DIAs in Minnesota low-income homes. The NorthernSTAR DIA laboratory was created to identify proper system components, designs, operating parameters, and installation procedures to assure high efficiency of field installed systems. Tests verified that heating loads up to 57,000 Btu/hr can be achieved with acceptable return water temperatures and supply air temperatures.

  20. Retrofitting Combined Space and Water Heating Systems: Laboratory Tests

    Energy Technology Data Exchange (ETDEWEB)

    Schoenbauer, B.; Bohac, D.; Huelman, P.; Olson, R.; Hewitt, M.

    2012-10-01

    Better insulated and tighter homes can often use a single heating plant for both space and domestic water heating. These systems, called dual integrated appliances (DIA) or combination systems, can operate at high efficiency and eliminate combustion safety issues associated by using a condensing, sealed combustion heating plant. Funds were received to install 400 DIAs in Minnesota low-income homes. The NorthernSTAR DIA laboratory was created to identify proper system components, designs, operating parameters, and installation procedures to assure high efficiency of field installed systems. Tests verified that heating loads up to 57,000 Btu/hr can be achieved with acceptable return water temperatures and supply air temperatures.

  1. Laboratory quality management system: road to accreditation and beyond.

    Science.gov (United States)

    Wadhwa, V; Rai, S; Thukral, T; Chopra, M

    2012-01-01

    This review attempts to clarify the concepts of Laboratory Quality Management System (Lab QMS) for a medical testing and diagnostic laboratory in a holistic way and hopes to expand the horizon beyond quality control (QC) and quality assurance. It provides an insight on accreditation bodies and highlights a glimpse of existing laboratory practices but essentially it takes the reader through the journey of accreditation and during the course of reading and understanding this document, prepares the laboratory for the same. Some of the areas which have not been highlighted previously include: requirement for accreditation consultants, laboratory infrastructure and scope, applying for accreditation, document preparation. This section is well supported with practical illustrations and necessary tables and exhaustive details like preparation of a standard operating procedure and a quality manual. Concept of training and privileging of staff has been clarified and a few of the QC exercises have been dealt with in a novel way. Finally, a practical advice for facing an actual third party assessment and caution needed to prevent post-assessment pitfalls has been dealt with.

  2. Laboratory quality management system: Road to accreditation and beyond

    Directory of Open Access Journals (Sweden)

    V Wadhwa

    2012-01-01

    Full Text Available This review attempts to clarify the concepts of Laboratory Quality Management System (Lab QMS for a medical testing and diagnostic laboratory in a holistic way and hopes to expand the horizon beyond quality control (QC and quality assurance. It provides an insight on accreditation bodies and highlights a glimpse of existing laboratory practices but essentially it takes the reader through the journey of accreditation and during the course of reading and understanding this document, prepares the laboratory for the same. Some of the areas which have not been highlighted previously include: requirement for accreditation consultants, laboratory infrastructure and scope, applying for accreditation, document preparation. This section is well supported with practical illustrations and necessary tables and exhaustive details like preparation of a standard operating procedure and a quality manual. Concept of training and privileging of staff has been clarified and a few of the QC exercises have been dealt with in a novel way. Finally, a practical advice for facing an actual third party assessment and caution needed to prevent post-assessment pitfalls has been dealt with.

  3. Drain Back Systems in Laboratory and in Practice

    DEFF Research Database (Denmark)

    Perers, Bengt; Furbo, Simon; Fan, Jianhua

    2015-01-01

    Drain Back systems with ETC collectors are tested and analyzed in a Danish - Chinese cooperation project. Experiences from early work at DTU, with drain back, low flow systems, was used to design two systems: 1) One laboratory system at DTU. 2) One demonstration system in a single family house...... in Sorö Denmark. Detailed monitoring and modelling/validation of the system in the DTU lab is done, to be able to generalize the results, to other climates and loads by simulation and to make design optimizations. The advantage with drain back, low flow systems, is that the system can be made more simple...... in the collector loop to have a safe reliable operation. The components should also be designed and marked so that only one correct mounting option is possible, like forward and return pipes to/from the collector of slightly different sizes or color. Adapted installer education and training is a very important...

  4. Venus Surface Power and Cooling System Design

    Science.gov (United States)

    Landis, Geoffrey A.; Mellott, Kenneth D.

    2004-01-01

    A radioisotope power and cooling system is designed to provide electrical power for the a probe operating on the surface of Venus. Most foreseeable electronics devices and sensors simply cannot operate at the 450 C ambient surface temperature of Venus. Because the mission duration is substantially long and the use of thermal mass to maintain an operable temperature range is likely impractical, some type of active refrigeration may be required to keep certain components at a temperature below ambient. The fundamental cooling requirements are comprised of the cold sink temperature, the hot sink temperature, and the amount of heat to be removed. In this instance, it is anticipated that electronics would have a nominal operating temperature of 300 C. Due to the highly thermal convective nature of the high-density atmosphere, the hot sink temperature was assumed to be 50 C, which provided a 500 C temperature of the cooler's heat rejecter to the ambient atmosphere. The majority of the heat load on the cooler is from the high temperature ambient surface environment on Venus. Assuming 5 cm radial thickness of ceramic blanket insulation, the ambient heat load was estimated at approximately 77 watts. With an estimated quantity of 10 watts of heat generation from electronics and sensors, and to accommodate some level of uncertainty, the total heat load requirement was rounded up to an even 100 watts. For the radioisotope Stirling power converter configuration designed, the Sage model predicts a thermodynamic power output capacity of 478.1 watts, which slightly exceeds the required 469.1 watts. The hot sink temperature is 1200 C, and the cold sink temperature is 500 C. The required heat input is 1740 watts. This gives a thermodynamic efficiency of 27.48 %. The maximum theoretically obtainable efficiency is 47.52 %. It is estimated that the mechanical efficiency of the power converter design is on the order of 85 %, based on experimental measurements taken from 500 watt power

  5. Customizing Laboratory Information Systems: Closing the Functionality Gap.

    Science.gov (United States)

    Gershkovich, Peter; Sinard, John H

    2015-09-01

    Highly customizable laboratory information systems help to address great variations in laboratory workflows, typical in Pathology. Often, however, built-in customization tools are not sufficient to add all of the desired functionality and improve systems interoperability. Emerging technologies and advances in medicine often create a void in functionality that we call a functionality gap. These gaps have distinct characteristics—a persuasive need to change the way a pathology group operates, the general availability of technology to address the missing functionality, the absence of this technology from your laboratory information system, and inability of built-in customization tools to address it. We emphasize the pervasive nature of these gaps, the role of pathology informatics in closing them, and suggest methods on how to achieve that. We found that a large number of the papers in the Journal of Pathology Informatics are concerned with these functionality gaps, and an even larger proportion of electronic posters and abstracts presented at the Pathology Informatics Summit conference each year deal directly with these unmet needs in pathology practice. A rapid, continuous, and sustainable approach to closing these gaps is critical for Pathology to provide the highest quality of care, adopt new technologies, and meet regulatory and financial challenges. The key element of successfully addressing functionality gaps is gap ownership—the ability to control the entire pathology information infrastructure with access to complementary systems and components. In addition, software developers with detailed domain expertise, equipped with right tools and methodology can effectively address these needs as they emerge.

  6. Colloid and surface chemistry a laboratory guide for exploration of the nano world

    CERN Document Server

    Bucak, Seyda

    2013-01-01

    Scientific Research The research processEthics in Science Design of Experiments Fundamentals of Scientific Computing, Nihat Baysal Recording Data: Keeping a Good Notebook Presenting Data: Writing a Laboratory ReportReferencesCharacterization Techniques Surface Tension Measurements, Seyda BucakViscosity/Rheological Measurements, Patrick UnderhillElectrokinetic Techniques, Marek KosmulskiDiffraction (XRD), Deniz RendeScattering, Ulf OlssonMicroscopy, Cem Levent Altan and Nico A.J.M. SommerdijkColloids and Surfaces Experiment 1: SedimentationExperiment 2: Determination of Critical Micelle Concent

  7. Study on Microbial Deposition and Contamination onto Six Surfaces Commonly Used in Chemical and Microbiological Laboratories

    Directory of Open Access Journals (Sweden)

    Elena Tamburini

    2015-07-01

    Full Text Available The worktops in both chemical and microbiological laboratories are the surfaces most vulnerable to damage and exposure to contamination by indoor pollutants. The rate at which particles are deposited on indoor surfaces is an important parameter to determine human exposure to airborne biological particles. In contrast to what has been established for inorganic pollutants, no limit has been set by law for microbial contamination in indoor air. To our knowledge, a comparative study on the effect of surfaces on the deposition of microbes has not been carried out. An evaluation of the microbial contamination of worktop materials could be of crucial importance, both for safety reasons and for the reliability of tests and experiments that need to be carried out in non-contaminated environments. The aim of this study was to evaluate the overall microbial contamination (fungi, mesophilic and psychrophilic bacteria, staphylococci on six widely used worktop materials in laboratories (glass, stainless steel, fine porcelain stoneware, post-forming laminate, high-performing laminate and enamel steel and to correlate it with the characteristics of the surfaces. After cleaning, the kinetics of microbial re-contamination were also evaluated for all surfaces.

  8. Factors in the Selection of Surface Disinfectants for Use in a Laboratory Animal Setting

    Science.gov (United States)

    Campagna, Michael V; Faure-Kumar, Emmanuelle; Treger, Janet A; Cushman, Jesse D; Grogan, Tristan R; Kasahara, Noriyuki; Lawson, Gregory W

    2016-01-01

    Because surface disinfectants are an important means of pathogen control within laboratory animal facilities, these products must have an appropriate spectrum of antimicrobial activity. However, many other factors must also be considered, including effects on human health, environmental safety, and animal behavior. Aqueous solutions of sodium hypochlorite often are considered to be the ‘gold standard’ for surface disinfection, but these products can be corrosive, caustic, and aversive in odor. This study was designed to identify disinfectants that are as effective as hypochlorite solutions but more acceptable for use in a laboratory animal setting. An antiviral disinfectant-efficacy assay was developed by using viral vectors that expressed green fluorescence protein as surrogates for wild-type viruses of concern in laboratory animals. Efficacy testing revealed that most of the products were highly effective when used against viral vectors in suspension. However, when the disinfectants were challenged by buffering virus in protein or drying virus on nonporous surfaces, the hypochlorite and peroxymonosulfate products performed the best. Review of safety data sheets for the agents indicated that a peroxide-based product was considerably safer than the other products tested and that the pH of most products was not conducive to disposal down a drain. Behavioral testing of Swiss Webster, C57Bl/6, and BALB/c mice showed that the hypochlorite- and peroxide-based products were clearly aversive, given that the mice consistently avoided these products. All of these factors must be considered when choosing the appropriate disinfectant. PMID:27025810

  9. Laboratory Flume Experiment with a Coded Structured Light System

    Science.gov (United States)

    Akca, D.; Seybold, H.

    2012-07-01

    The topography of inland deltas is influenced chiefly by the water-sediment balance in distributary channels and local evaporation and seepage rates. In a previous study, a reduced complexity model has been applied to simulate the process of inland delta formation. Results have been compared with the Okavango Delta, Botswana and with a laboratory experiment. Both in the macro scale and the micro scale cases, high quality digital elevation models (DEM) are essential. This work elaborates the laboratory experiment where an artificial inland delta is generated on laboratory scale and its topography is measured using a Breuckmann 3D scanner. The space-time evolution of the inland delta is monitored in the consecutive DEM layers. Regarding the 1.0m x 1.0m x 0.3m size of the working area, better than 100 micron precision is achieved which gives a relative precision of 1/10 000. The entire 3D modelling workflow is presented in terms of scanning, co-registration, surface generation, editing, and visualization steps. The co-registered high resolution topographic data allows us to analyse the stratigraphy patterns of the experiment and gain quantitative insight into the spatio-temporal evolution of the delta formation process.

  10. LABORATORY FLUME EXPERIMENT WITH A CODED STRUCTURED LIGHT SYSTEM

    Directory of Open Access Journals (Sweden)

    D. Akca

    2012-07-01

    Full Text Available The topography of inland deltas is influenced chiefly by the water-sediment balance in distributary channels and local evaporation and seepage rates. In a previous study, a reduced complexity model has been applied to simulate the process of inland delta formation. Results have been compared with the Okavango Delta, Botswana and with a laboratory experiment. Both in the macro scale and the micro scale cases, high quality digital elevation models (DEM are essential. This work elaborates the laboratory experiment where an artificial inland delta is generated on laboratory scale and its topography is measured using a Breuckmann 3D scanner. The space-time evolution of the inland delta is monitored in the consecutive DEM layers. Regarding the 1.0m x 1.0m x 0.3m size of the working area, better than 100 micron precision is achieved which gives a relative precision of 1/10 000. The entire 3D modelling workflow is presented in terms of scanning, co-registration, surface generation, editing, and visualization steps. The co-registered high resolution topographic data allows us to analyse the stratigraphy patterns of the experiment and gain quantitative insight into the spatio-temporal evolution of the delta formation process.

  11. Data integrity by validation of a computer based laboratory system

    OpenAIRE

    Jasmin, Ramić

    2017-01-01

    The thesis deals with the assurance of regulatory compliance and validation of computer supported laboratory systems in the pharmaceutical industry. It describes the functioning and importance of regulatory authorities and explains the standards and good practice examples to be observed in the validation process. By actively introducing the act on electronic records and signatures, food and drug agencies have succeeded in setting up clear requirements and guidelines in the pharmaceutical indu...

  12. Laboratory diagnostic methods, system of quality and validation

    Directory of Open Access Journals (Sweden)

    Ašanin Ružica

    2005-01-01

    Full Text Available It is known that laboratory investigations secure safe and reliable results that provide a final confirmation of the quality of work. Ideas, planning, knowledge, skills, experience, and environment, along with good laboratory practice, quality control and reliability of quality, make the area of biological investigations very complex. In recent years, quality control, including the control of work in the laboratory, is based on international standards and is used at that level. The implementation of widely recognized international standards, such as the International Standard ISO/IEC 17025 (1 and the implementing of the quality system series ISO/IEC 9000 (2 have become the imperative on the grounds of which laboratories have a formal, visible and corresponding system of quality. The diagnostic methods that are used must constantly yield results which identify the animal as positive or negative, and the precise status of the animal is determined with a predefined degree of statistical significance. Methods applied on a selected population reduce the risk of obtaining falsely positive or falsely negative results. A condition for this are well conceived and documented methods, with the application of the corresponding reagents, and work with professional and skilled staff. This process requires also a consistent implementation of the most rigorous experimental plans, epidemiological and statistical data and estimations, with constant monitoring of the validity of the applied methods. Such an approach is necessary in order to cut down the number of misconceptions and accidental mistakes, for a referent population of animals on which the validity of a method is tested. Once a valid method is included in daily routine investigations, it is necessary to apply constant monitoring for the purpose of internal quality control, in order adequately to evaluate its reproducibility and reliability. Consequently, it is necessary at least twice yearly to conduct

  13. Surface Waters Information Management System (SWIMS)

    Data.gov (United States)

    Kansas Data Access and Support Center — The Surface Waters Information Management System (SWIMS) has been designed to meet multi-agency hydrologic database needs for Kansas. The SWIMS project was supported...

  14. Surface Meteorological Observation System (SMOS) Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Ritsche, MT

    2008-03-01

    The Surface Meteorological Observation System (SMOS) mostly uses conventional in situ sensors to obtain 1-minute, 30-minute, and 1440-minute (daily) averages of surface wind speed, wind direction, air temperature, relative humidity (RH), barometric pressure, and precipitation at the Central Facility and many of the extended facilities of the Southern Great Plains (SGP) climate research site. The SMOSs are not calibrated as systems. The sensors and the data logger (which includes the analog-to-digital converter, or A/D) are calibrated separately. All systems are installed using components that have a current calibration. SMOSs have not been installed at extended facilities located within about 10 km of existing surface meteorological stations, such as those of the Oklahoma Mesonet. The Surface Meteorological Observation Systems are used to create climatology for each particular location, and to verify the output of numerical weather forecast and other model output. They are also used to “ground-truth” other remote sensing equipment.

  15. Observation and control system of the thermohydraulic assays laboratory

    International Nuclear Information System (INIS)

    Santome, D.; Hualde, R.

    1990-01-01

    The Thermohydraulic Assays Laboratory (L.E.T.) is an installation whose purpose will be the components testing and the CAREM-25 reactor thermohydraulic processes operation dynamics. This plant is located at Pilcaniyeu, province of Rio Negro. Part of the tests which will be carried out consist in the use of different control strategies. The control of the systems by digital processors (control by software) has been decided to proceed with a maximum flexibility and capacity to make changes in the algorithms. This work describes the design and implementation of a digital control system to command the three circuits of the installation. (Author) [es

  16. Power supplies for space systems quality assurance by Sandia Laboratories

    International Nuclear Information System (INIS)

    Hannigan, R.L.; Harnar, R.R.

    1976-07-01

    The Sandia Laboratories' participation in Quality Assurance programs for Radioisotopic Thermoelectric Generators which have been used in space systems over the past 10 years is summarized. Basic elements of this QA program are briefly described and recognition of assistance from other Sandia organizations is included. Descriptions of the various systems for which Sandia has had the QA responsibility are presented, including SNAP 19 (Nimbus, Pioneer, Viking), SNAP 27 (Apollo), Transit, Multi-Hundred Watt (LES 8/9 and MJS), and a new program, High-Performance Generator Mod 3. The outlook for Sandia participation in RTG programs for the next several years is noted

  17. Laboratory information management system at the Hanford Site

    Energy Technology Data Exchange (ETDEWEB)

    Leggett, W.; Barth, D.; Ibsen, T.; Newman, B.

    1994-03-01

    In January of 1994 an important new technology was brought on line to help in the monumental waste management and environmental restoration work at the Hanford Site. Cleanup at the Hanford Site depends on analytical chemistry information to identify contaminates, design and monitor cleanup processes, assure worker safety, evaluate progress, and prove completion. The new technology, a laboratory information management system (LIMS) called ``LABCORE,`` provides the latest systems to organize and communicate the analytical tasks: track work and samples; collect and process data, prepare reports, and store data in readily accessible electronic form.

  18. Mars' surface radiation environment measured with the Mars Science Laboratory's Curiosity rover.

    Science.gov (United States)

    Hassler, Donald M; Zeitlin, Cary; Wimmer-Schweingruber, Robert F; Ehresmann, Bent; Rafkin, Scot; Eigenbrode, Jennifer L; Brinza, David E; Weigle, Gerald; Böttcher, Stephan; Böhm, Eckart; Burmeister, Soenke; Guo, Jingnan; Köhler, Jan; Martin, Cesar; Reitz, Guenther; Cucinotta, Francis A; Kim, Myung-Hee; Grinspoon, David; Bullock, Mark A; Posner, Arik; Gómez-Elvira, Javier; Vasavada, Ashwin; Grotzinger, John P

    2014-01-24

    The Radiation Assessment Detector (RAD) on the Mars Science Laboratory's Curiosity rover began making detailed measurements of the cosmic ray and energetic particle radiation environment on the surface of Mars on 7 August 2012. We report and discuss measurements of the absorbed dose and dose equivalent from galactic cosmic rays and solar energetic particles on the martian surface for ~300 days of observations during the current solar maximum. These measurements provide insight into the radiation hazards associated with a human mission to the surface of Mars and provide an anchor point with which to model the subsurface radiation environment, with implications for microbial survival times of any possible extant or past life, as well as for the preservation of potential organic biosignatures of the ancient martian environment.

  19. Mars' Surface Radiation Environment Measured with the Mars Science Laboratory's Curiosity Rover

    Science.gov (United States)

    Hassler, Donald M.; Zeitlin, Cary; Wimmer-Schweingruber, Robert F.; Ehresmann, Bent; Rafkin, Scot; Eigenbrode, Jennifer L.; Brinza, David E.; Weigle, Gerald; Böttcher, Stephan; Böhm, Eckart; Burmeister, Soenke; Guo, Jingnan; Köhler, Jan; Martin, Cesar; Reitz, Guenther; Cucinotta, Francis A.; Kim, Myung-Hee; Grinspoon, David; Bullock, Mark A.; Posner, Arik; Gómez-Elvira, Javier; Vasavada, Ashwin; Grotzinger, John P.; MSL Science Team; Kemppinen, Osku; Cremers, David; Bell, James F.; Edgar, Lauren; Farmer, Jack; Godber, Austin; Wadhwa, Meenakshi; Wellington, Danika; McEwan, Ian; Newman, Claire; Richardson, Mark; Charpentier, Antoine; Peret, Laurent; King, Penelope; Blank, Jennifer; Schmidt, Mariek; Li, Shuai; Milliken, Ralph; Robertson, Kevin; Sun, Vivian; Baker, Michael; Edwards, Christopher; Ehlmann, Bethany; Farley, Kenneth; Griffes, Jennifer; Miller, Hayden; Newcombe, Megan; Pilorget, Cedric; Rice, Melissa; Siebach, Kirsten; Stack, Katie; Stolper, Edward; Brunet, Claude; Hipkin, Victoria; Léveillé, Richard; Marchand, Geneviève; Sánchez, Pablo Sobrón; Favot, Laurent; Cody, George; Steele, Andrew; Flückiger, Lorenzo; Lees, David; Nefian, Ara; Martin, Mildred; Gailhanou, Marc; Westall, Frances; Israël, Guy; Agard, Christophe; Baroukh, Julien; Donny, Christophe; Gaboriaud, Alain; Guillemot, Philippe; Lafaille, Vivian; Lorigny, Eric; Paillet, Alexis; Pérez, René; Saccoccio, Muriel; Yana, Charles; Armiens-Aparicio, Carlos; Rodríguez, Javier Caride; Blázquez, Isaías Carrasco; Gómez, Felipe Gómez; Hettrich, Sebastian; Malvitte, Alain Lepinette; Jiménez, Mercedes Marín; Martínez-Frías, Jesús; Martín-Soler, Javier; Martín-Torres, F. Javier; Jurado, Antonio Molina; Mora-Sotomayor, Luis; Caro, Guillermo Muñoz; López, Sara Navarro; Peinado-González, Verónica; Pla-García, Jorge; Manfredi, José Antonio Rodriguez; Romeral-Planelló, Julio José; Fuentes, Sara Alejandra Sans; Martinez, Eduardo Sebastian; Redondo, Josefina Torres; Urqui-O'Callaghan, Roser; Mier, María-Paz Zorzano; Chipera, Steve; Lacour, Jean-Luc; Mauchien, Patrick; Sirven, Jean-Baptiste; Manning, Heidi; Fairén, Alberto; Hayes, Alexander; Joseph, Jonathan; Squyres, Steven; Sullivan, Robert; Thomas, Peter; Dupont, Audrey; Lundberg, Angela; Melikechi, Noureddine; Mezzacappa, Alissa; Berger, Thomas; Matthia, Daniel; Prats, Benito; Atlaskin, Evgeny; Genzer, Maria; Harri, Ari-Matti; Haukka, Harri; Kahanpää, Henrik; Kauhanen, Janne; Kemppinen, Osku; Paton, Mark; Polkko, Jouni; Schmidt, Walter; Siili, Tero; Fabre, Cécile; Wray, James; Wilhelm, Mary Beth; Poitrasson, Franck; Patel, Kiran; Gorevan, Stephen; Indyk, Stephen; Paulsen, Gale; Gupta, Sanjeev; Bish, David; Schieber, Juergen; Gondet, Brigitte; Langevin, Yves; Geffroy, Claude; Baratoux, David; Berger, Gilles; Cros, Alain; d'Uston, Claude; Forni, Olivier; Gasnault, Olivier; Lasue, Jérémie; Lee, Qiu-Mei; Maurice, Sylvestre; Meslin, Pierre-Yves; Pallier, Etienne; Parot, Yann; Pinet, Patrick; Schröder, Susanne; Toplis, Mike; Lewin, Éric; Brunner, Will; Heydari, Ezat; Achilles, Cherie; Oehler, Dorothy; Sutter, Brad; Cabane, Michel; Coscia, David; Israël, Guy; Szopa, Cyril; Dromart, Gilles; Robert, François; Sautter, Violaine; Le Mouélic, Stéphane; Mangold, Nicolas; Nachon, Marion; Buch, Arnaud; Stalport, Fabien; Coll, Patrice; François, Pascaline; Raulin, François; Teinturier, Samuel; Cameron, James; Clegg, Sam; Cousin, Agnès; DeLapp, Dorothea; Dingler, Robert; Jackson, Ryan Steele; Johnstone, Stephen; Lanza, Nina; Little, Cynthia; Nelson, Tony; Wiens, Roger C.; Williams, Richard B.; Jones, Andrea; Kirkland, Laurel; Treiman, Allan; Baker, Burt; Cantor, Bruce; Caplinger, Michael; Davis, Scott; Duston, Brian; Edgett, Kenneth; Fay, Donald; Hardgrove, Craig; Harker, David; Herrera, Paul; Jensen, Elsa; Kennedy, Megan R.; Krezoski, Gillian; Krysak, Daniel; Lipkaman, Leslie; Malin, Michael; McCartney, Elaina; McNair, Sean; Nixon, Brian; Posiolova, Liliya; Ravine, Michael; Salamon, Andrew; Saper, Lee; Stoiber, Kevin; Supulver, Kimberley; Van Beek, Jason; Van Beek, Tessa; Zimdar, Robert; French, Katherine Louise; Iagnemma, Karl; Miller, Kristen; Summons, Roger; Goesmann, Fred; Goetz, Walter; Hviid, Stubbe; Johnson, Micah; Lefavor, Matthew; Lyness, Eric; Breves, Elly; Dyar, M. Darby; Fassett, Caleb; Blake, David F.; Bristow, Thomas; DesMarais, David; Edwards, Laurence; Haberle, Robert; Hoehler, Tori; Hollingsworth, Jeff; Kahre, Melinda; Keely, Leslie; McKay, Christopher; Wilhelm, Mary Beth; Bleacher, Lora; Brinckerhoff, William; Choi, David; Conrad, Pamela; Dworkin, Jason P.; Floyd, Melissa; Freissinet, Caroline; Garvin, James; Glavin, Daniel; Harpold, Daniel; Jones, Andrea; Mahaffy, Paul; Martin, David K.; McAdam, Amy; Pavlov, Alexander; Raaen, Eric; Smith, Michael D.; Stern, Jennifer; Tan, Florence; Trainer, Melissa; Meyer, Michael; Voytek, Mary; Anderson, Robert C.; Aubrey, Andrew; Beegle, Luther W.; Behar, Alberto; Blaney, Diana; Calef, Fred; Christensen, Lance; Crisp, Joy A.; DeFlores, Lauren; Ehlmann, Bethany; Feldman, Jason; Feldman, Sabrina; Flesch, Gregory; Hurowitz, Joel; Jun, Insoo; Keymeulen, Didier; Maki, Justin; Mischna, Michael; Morookian, John Michael; Parker, Timothy; Pavri, Betina; Schoppers, Marcel; Sengstacken, Aaron; Simmonds, John J.; Spanovich, Nicole; Juarez, Manuel de la Torre; Webster, Christopher R.; Yen, Albert; Archer, Paul Douglas; Jones, John H.; Ming, Douglas; Morris, Richard V.; Niles, Paul; Rampe, Elizabeth; Nolan, Thomas; Fisk, Martin; Radziemski, Leon; Barraclough, Bruce; Bender, Steve; Berman, Daniel; Dobrea, Eldar Noe; Tokar, Robert; Vaniman, David; Williams, Rebecca M. E.; Yingst, Aileen; Lewis, Kevin; Leshin, Laurie; Cleghorn, Timothy; Huntress, Wesley; Manhès, Gérard; Hudgins, Judy; Olson, Timothy; Stewart, Noel; Sarrazin, Philippe; Grant, John; Vicenzi, Edward; Wilson, Sharon A.; Hamilton, Victoria; Peterson, Joseph; Fedosov, Fedor; Golovin, Dmitry; Karpushkina, Natalya; Kozyrev, Alexander; Litvak, Maxim; Malakhov, Alexey; Mitrofanov, Igor; Mokrousov, Maxim; Nikiforov, Sergey; Prokhorov, Vasily; Sanin, Anton; Tretyakov, Vladislav; Varenikov, Alexey; Vostrukhin, Andrey; Kuzmin, Ruslan; Clark, Benton; Wolff, Michael; McLennan, Scott; Botta, Oliver; Drake, Darrell; Bean, Keri; Lemmon, Mark; Schwenzer, Susanne P.; Anderson, Ryan B.; Herkenhoff, Kenneth; Lee, Ella Mae; Sucharski, Robert; Hernández, Miguel Ángel de Pablo; Ávalos, Juan José Blanco; Ramos, Miguel; Malespin, Charles; Plante, Ianik; Muller, Jan-Peter; Navarro-González, Rafael; Ewing, Ryan; Boynton, William; Downs, Robert; Fitzgibbon, Mike; Harshman, Karl; Morrison, Shaunna; Dietrich, William; Kortmann, Onno; Palucis, Marisa; Sumner, Dawn Y.; Williams, Amy; Lugmair, Günter; Wilson, Michael A.; Rubin, David; Jakosky, Bruce; Balic-Zunic, Tonci; Frydenvang, Jens; Jensen, Jaqueline Kløvgaard; Kinch, Kjartan; Koefoed, Asmus; Madsen, Morten Bo; Stipp, Susan Louise Svane; Boyd, Nick; Campbell, John L.; Gellert, Ralf; Perrett, Glynis; Pradler, Irina; VanBommel, Scott; Jacob, Samantha; Owen, Tobias; Rowland, Scott; Atlaskin, Evgeny; Savijärvi, Hannu; García, César Martín; Mueller-Mellin, Reinhold; Bridges, John C.; McConnochie, Timothy; Benna, Mehdi; Franz, Heather; Bower, Hannah; Brunner, Anna; Blau, Hannah; Boucher, Thomas; Carmosino, Marco; Atreya, Sushil; Elliott, Harvey; Halleaux, Douglas; Rennó, Nilton; Wong, Michael; Pepin, Robert; Elliott, Beverley; Spray, John; Thompson, Lucy; Gordon, Suzanne; Newsom, Horton; Ollila, Ann; Williams, Joshua; Vasconcelos, Paulo; Bentz, Jennifer; Nealson, Kenneth; Popa, Radu; Kah, Linda C.; Moersch, Jeffrey; Tate, Christopher; Day, Mackenzie; Kocurek, Gary; Hallet, Bernard; Sletten, Ronald; Francis, Raymond; McCullough, Emily; Cloutis, Ed; ten Kate, Inge Loes; Kuzmin, Ruslan; Arvidson, Raymond; Fraeman, Abigail; Scholes, Daniel; Slavney, Susan; Stein, Thomas; Ward, Jennifer; Berger, Jeffrey; Moores, John E.

    2014-01-01

    The Radiation Assessment Detector (RAD) on the Mars Science Laboratory's Curiosity rover began making detailed measurements of the cosmic ray and energetic particle radiation environment on the surface of Mars on 7 August 2012. We report and discuss measurements of the absorbed dose and dose equivalent from galactic cosmic rays and solar energetic particles on the martian surface for ~300 days of observations during the current solar maximum. These measurements provide insight into the radiation hazards associated with a human mission to the surface of Mars and provide an anchor point with which to model the subsurface radiation environment, with implications for microbial survival times of any possible extant or past life, as well as for the preservation of potential organic biosignatures of the ancient martian environment.

  20. Laboratory Studies on Surface Sampling of Bacillus anthracis Contamination: Summary, Gaps, and Recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F.; Amidan, Brett G.; Hu, Rebecca

    2011-11-28

    This report summarizes previous laboratory studies to characterize the performance of methods for collecting, storing/transporting, processing, and analyzing samples from surfaces contaminated by Bacillus anthracis or related surrogates. The focus is on plate culture and count estimates of surface contamination for swab, wipe, and vacuum samples of porous and nonporous surfaces. Summaries of the previous studies and their results were assessed to identify gaps in information needed as inputs to calculate key parameters critical to risk management in biothreat incidents. One key parameter is the number of samples needed to make characterization or clearance decisions with specified statistical confidence. Other key parameters include the ability to calculate, following contamination incidents, the (1) estimates of Bacillus anthracis contamination, as well as the bias and uncertainties in the estimates, and (2) confidence in characterization and clearance decisions for contaminated or decontaminated buildings. Gaps in knowledge and understanding identified during the summary of the studies are discussed and recommendations are given for future studies.

  1. Radioactivity decontamination of materials commonly used as surfaces in general-purpose radioisotope laboratories.

    Science.gov (United States)

    Leonardi, Natalia M; Tesán, Fiorella C; Zubillaga, Marcela B; Salgueiro, María J

    2014-12-01

    In accord with as-low-as-reasonably-achievable and good-manufacturing-practice concepts, the present study evaluated the efficiency of radioactivity decontamination of materials commonly used in laboratory surfaces and whether solvent spills on these materials affect the findings. Four materials were evaluated: stainless steel, a surface comprising one-third acrylic resin and two-thirds natural minerals, an epoxy cover, and vinyl-based multipurpose flooring. Radioactive material was eluted from a (99)Mo/(99m)Tc generator, and samples of the surfaces were control-contaminated with 37 MBq (100 μL) of this eluate. The same procedure was repeated with samples of surfaces previously treated with 4 solvents: methanol, methyl ethyl ketone, acetone, and ethanol. The wet radioactive contamination was allowed to dry and then was removed with cotton swabs soaked in soapy water. The effectiveness of decontamination was defined as the percentage of activity removed per cotton swab, and the efficacy of decontamination was defined as the total percentage of activity removed, which was obtained by summing the percentages of activity in all the swabs required to complete the decontamination. Decontamination using our protocol was most effective and most efficacious for stainless steel and multipurpose flooring. Moreover, treatment with common organic solvents seemed not to affect the decontamination of these surfaces. Decontamination of the other two materials was less efficient and was interfered with by the organic solvents; there was also great variability in the overall results obtained for these other two materials. In expanding our laboratory, it is possible for us to select those surface materials on which our decontamination protocol works best. © 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  2. The Lawrence Livermore National Laboratory Intelligent Actinide Analysis System

    International Nuclear Information System (INIS)

    Buckley, W.M.; Carlson, J.B.; Koenig, Z.M.

    1993-01-01

    The authors have developed an Intelligent Actinide Analysis System (IAAS) for Materials Management to use in the Plutonium Facility at the Lawrence Livermore National Laboratory. The IAAS will measure isotopic ratios for plutonium and other actinides non-destructively by high-resolution gamma-ray spectrometry. This system will measure samples in a variety of matrices and containers. It will provide automated control of many aspects of the instrument that previously required manual intervention and/or control. The IAAS is a second-generation instrument, based on experience in fielding gamma isotopic systems, that is intended to advance non-destructive actinide analysis for nuclear safeguards in performance, automation, ease of use, adaptability, systems integration and extensibility to robotics. It uses a client-server distributed monitoring and control architecture. The IAAS uses MGA as the isotopic analysis code. The design of the IAAS reduces the need for operator intervention, operator training, and operator exposure

  3. The MIT Lincoln Laboratory optical systems test facility

    Science.gov (United States)

    Harrison, David C.; Hayes, Alexander G.; Jiang, Leaf A.; Hines, Eric L.; Richardson, Jonathan M.

    2006-05-01

    The Optical Systems Test Facility was established at MIT Lincoln Laboratory to support a broad scope of program areas, encompassing tactical ground-based sensors through strategic space-based sensors. The Optical Systems Test Facility comprises several separate ranges developed as a coordinated set of test sites at MIT Lincoln Laboratory. There are currently four separate ranges in the facility, an active range (Laser Radar Test Facility), a passive range (Seeker Experimental System), an aerosol range (Standoff Aerosol Active Signature Testbed) and an optical material measurements range. The active range has optical and target facilities for evaluating elements of laser radar sensors as well as complete ladar systems. It has facilities for simulating long range wavefronts and for dynamic target motions. The passive range concentrates on evaluating passive infrared sensors, with capabilities for static and dynamic scene generation in both cryogenic and room temperature environments. The aerosol range is currently configured for the measurement of both particulate and bio-agent aerosol dispersion characteristics. The optical materials measurements range started with measurement capabilities for laser radar target materials and is currently being expanded to measure both emissivity and reflectance of materials from the visible through the infrared.

  4. JCMT active surface control system: implementation

    Science.gov (United States)

    Smith, Ian A.

    1998-05-01

    The James Clerk Maxwell Telescope on the summit of Mauna Kea in Hawaii is a 15 meter sub-millimeter telescope which operates in the 350 microns to 2 millimeter region. The primary antenna surface consists of 276 panels, each of which is positioned by 3 stepper motors. In order to achieve the highest possible surface accuracy we are embarking upon a project to actively control the position of the panels adjuster system is based on a 6809 micro connected to the control computer by a GPIB interface. This system is slow and inflexible and it would prove difficult to build an active surface control system with it. Part of the upgrade project is to replace the existing micro with a 68060 VME micro. The poster paper will describe how the temperature of the antenna is monitored with the new system, how a Finite Element Analyses package transforms temperature changes into a series of panel adjuster moves, and how these moves are then applied to the surface. The FEA package will run on a high end Sun workstation. A series of DRAMA tasks distributed between the workstation and the Baja 68060 VxWorks Active Surface Control System micro will control the temperature monitoring, FEA and panel adjustment activities. Users can interact with the system via a Tcl/TK based GUI.

  5. Summary report: Assessment of deep injection well associated surface soils at the Idaho National Engineering Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Pole, S.B.

    1993-01-01

    This report summarizes sampling activities and analytical results of the chemical and radiological content of surface soils from storm water retention basins and drainage ditches associated with eight deep injection wells at the Idaho National Engineering Laboratory. The results of the sampling effort were intended to support permitting of the injection wells by the State of Idaho Department of Water Resources. In August 1992, the surface soils associated with eight storm water retention basins and ditches were sampled. All samples were collected and analyzed in accordance with a written sampling and analysis plan. The samples were analyzed by an off-Site contract laboratory, and the results were compared to local and regional soil analytical data to determine the presence of contaminants. The results indicated that the surface soils from the storm water retention basins and ditches did not have concentrations of metals or radionuclides greater than the range of concentrations found in local and regional soils. Volatile organic compounds were below detection limits.

  6. Adsorption of Ten Microcystin Congeners to Common Laboratory-Ware Is Solvent and Surface Dependent

    Directory of Open Access Journals (Sweden)

    Stefan Altaner

    2017-04-01

    Full Text Available Cyanobacteria can produce heptapetides called microcystins (MC which are harmful to humans due to their ability to inhibit cellular protein phosphatases. Quantitation of these toxins can be hampered by their adsorption to common laboratory-ware during sample processing and analysis. Because of their structural diversity (>100 congeners and different physico-chemical properties, they vary in their adsorption to surfaces. In this study, the adsorption of ten different MC congeners (encompassing non-arginated to doubly-arginated congeners to common laboratory-ware was assessed using different solvent combinations. Sample handling steps were mimicked with glass and polypropylene pipettes and vials with increasing methanol concentrations at two pH levels, before analysis by liquid chromatography-tandem mass spectrometry. We demonstrated that MC adsorb to polypropylene surfaces irrespective of pH. After eight successive pipet actions using polypropylene tips ca. 20% of the MC were lost to the surface material, which increased to 25%–40% when solutions were acidified. The observed loss was alleviated by changing the methanol (MeOH concentration in the final solvent. The required MeOH concentration varied depending on which congener was present. Microcystins only adsorbed to glass pipettes (loss up to 30% after eight pipet actions when in acidified aqueous solutions. The latter appeared largely dependent on the presence of ionizable groups, such as arginine residues.

  7. Application of the Toyota Production System improves core laboratory operations.

    Science.gov (United States)

    Rutledge, Joe; Xu, Min; Simpson, Joanne

    2010-01-01

    To meet the increased clinical demands of our hospital expansion, improve quality, and reduce costs, our tertiary care, pediatric core laboratory used the Toyota Production System lean processing to reorganize our 24-hour, 7 d/wk core laboratory. A 4-month, consultant-driven process removed waste, led to a physical reset of the space to match the work flow, and developed a work cell for our random access analyzers. In addition, visual controls, single piece flow, standard work, and "5S" were instituted. The new design met our goals as reflected by achieving and maintaining improved turnaround time (TAT; mean for creatinine reduced from 54 to 23 minutes) with increased testing volume (20%), monetary savings (4 full-time equivalents), decreased variability in TAT, and better space utilization (25% gain). The project had the unanticipated consequence of eliminating STAT testing because our in-laboratory TAT for routine testing was less than our prior STAT turnaround goal. The viability of this approach is demonstrated by sustained gains and further PDCA (Plan, Do, Check, Act) improvements during the 4 years after completion of the project.

  8. Report on the Acadiana Research Laboratory nuclear microprobe system

    Science.gov (United States)

    Glass, Gary A.; Hollerman, William A.; Hynes, Shelly F.; Fournet, Justin; Bailey, Alan M.; Liao, Changgeng

    2001-07-01

    The Acadiana Research Laboratory of the University of Louisiana at Lafayette provides high energy ion beams for materials research. Major components of the ion beam systems include a National Electrostatics Corporation (NEC) 1.7 MV tandem Pelletron accelerator system with both SNICS and RF ion sources and a Varian CF-4 200 kV implanter. The NEC Pelletron has three operational beamlines that provide a wide range of capabilities for materials modification and analysis, including such techniques as PIXE, PIGE, RBS, RFS, TOF-ERDA and ion implantation. An Oxford Microbeams Ltd. microprobe system was recently declared operational with the attainment of a 1.5 μm×2.0 μm beam spot size. Microprobe techniques presently available include μPIXE, μRBS and scanning transmission ion microscopy (STIM).

  9. Limits determination of microbial contamination present on surfaces from a pharmaceutical microbiology district reference laboratory

    Directory of Open Access Journals (Sweden)

    Natalia Charry

    2016-06-01

    Full Text Available Context: The bioburden present on the pharmaceutical microbiology laboratory’s surfaces, may increase the risk of cross-contamination when analytical tests are being carried out; periodic monitoring allows to set limits that reduce the risk. Aims: To determinate the limits of bioburden present on seven surfaces of the pharmaceutical microbiology laboratory, after the cleaning and disinfection process. Methods: The swabbing method was used for sampling. With a 25 cm2 stencil and a sterile swab, a sample was taken, passing the swab over five points of every surface chosen. A total aerobic microbial count and a total yeast and mold count was done. Finally, the average and the standard deviation of the counts was obtained. Results: The average from the counts obtained on each surface selected for the study, were below the recommended limits by international entities like the World Health Organization and the European Union, between others; also, the results generated in this study, allow to classify the biosafety cabinet as an ISO 5 area and the other areas as ISO 7. Conclusions: Bioburden levels on the tested surfaces are considered low, reducing the risk of cross-contamination, which could have a negative impact on laboratory’s activities. Also, it follows that disinfectant concentration used, is effectively.

  10. Surface Defects in Sheet Metal Forming: a Simulative Laboratory Device and Comparison with FE Analysis

    Science.gov (United States)

    Thuillier, Sandrine; Le Port, Alban; Manach, Pierre-Yves

    2011-08-01

    Surface defects are small concave imperfections that can develop during forming on outer convex panels of automotive parts like doors. They occur during springback steps, after drawing in the vicinity of bending over a curved line and flanging/hemming in the vicinity of the upper corner of a door. They can alter significantly the final quality of the automobile and it is of primary importance to deal with them as early as possible in the design of the forming tools. The aim of this work is to reproduce at the laboratory scale such a defect, in the case of the flanging along a curved edge, made of two orthogonal straight part of length 50 mm and joint by a curved line. A dedicated device has been designed and steel samples were tested. Each sample was measured initially (after laser cutting) and after flanging, with a 3D measuring machine. 2D profiles were extracted and the curvature was calculated. Surface defects were defined between points where the curvature sign changed. Isovalues of surface defect depth could then be plotted, thus displaying also the spatial geometry on the part surface. An experimental database has been created on the influence of process parameters like the flanging height and the flanging radius. Numerical simulations have been performed with the finite element code Abaqus to predict the occurrence of such surface defects and to analyze stress and strain distribution within the defect area.

  11. Automatic opening system for radioactive source in teaching laboratory

    International Nuclear Information System (INIS)

    Seren, Maria Emilia Gibin; Gaal, Vladimir; Rodrigues, Varlei; Morais, Sergio Luiz de

    2013-01-01

    Compton scattering phenomenon is experimentally studied during the medical physics laboratory course at the University of Campinas (UNICAMP). The Teaching Laboratory of Medical Physics from IFGW/UNICAMP has a structure for its development: a fixed 137 Cs sealed source with activity 610.5MBq, whose emitted radiation collides on a target, and a scintillation detector that turns around the target and detects scattered photons spectrum. 137 Cs source is stored in a lead shield with a collimating window for the gamma radiation emitted with energy of 0.662MeV. This source is exposed only when attenuation barrier protecting the collimating window is opened. The process of opening and closing the attenuation barrier may deliver radiation dose to users when done manually. Taking into account the stochastic harmful effects of ionizing radiation, the objective of this project was to develop an automatic exposure system of the radioactive source in order to reduce the dose during the Compton scattering experiment. The developed system is micro controlled and performs standard operating routines and responds to emergencies. Electromagnetic lock enables quick closing barrier by gravity in case of interruption of electrical current circuit. Besides reducing the total dose of lab users, the system adds more security in the routine since it limits access to the source and prevents accidental exposure. (author)

  12. Design considerations for laboratory robotics systems handling toxic substances

    International Nuclear Information System (INIS)

    Stelting, K.M.; Rollheiser, J.J.

    1987-01-01

    This paper discusses design issues pertinent to development of reliable robotic systems for handling toxic substances, using examples from Midwest Research Institute's experience with the full range of materials selected by the federal government for toxicology testing. This includes laboratory work with substances known to have adverse toxicological effects (e.g., known carcinogens) as well as chemicals selected for evaluation of their toxic potential. Chemicals under evaluation include pharmaceuticals, industrial chemicals, solvents, pesticides, and a variety of other chemicals, solvents, pesticides, and a variety of other chemicals to which the populace is exposed in the workplace or in their daily lives

  13. Sandia National Laboratories, California Environmental Management System program manual.

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, Barbara L.

    2012-03-01

    The Sandia National Laboratories, California (SNL/CA) Environmental Management System (EMS) Program Manual documents the elements of the site EMS Program. The SNL/CA EMS Program conforms to the International Standard on Environmental Management Systems, ISO 14001:2004and Department of Energy (DOE) Order 436.1. Sandia National Laboratories, California (SNL/CA) has maintained functional environmental programs to assist with regulatory compliance for more than 30 years. During 2005, these existing programs were rolled into a formal environmental management system (EMS) that expands beyond the traditional compliance focus to managing and improving environmental performance and stewardship practices for all site activities. An EMS is a set of inter-related elements that represent a continuing cycle of planning, implementing, evaluating, and improving processes and actions undertaken to achieve environmental policy and goals. The SNL/CA EMS Program conforms to the International Standard for Environmental Management Systems, ISO 14001:2004 (ISO 2004). The site first received ISO 14001 certification in September 2006 and recertification in 2009. SNL/CA's EMS Program is applicable to the Sandia, Livermore site only. Although SNL/CA operates as one organizational division of the overall Sandia National Laboratories, the EMS Program is site-specific, with site-specific objectives and targets. SNL/CA (Division 8000) benefits from the organizational structure as it provides corporate level policies, procedures, and standards, and established processes that connect to and support elements of the SNL/CA EMS Program. Additionally, SNL/CA's EMS Program benefits from two corporate functional programs (Facilities Energy and Water Resource Management and Fleet Services programs) that maintain responsibility for energy management and fleet services for all Sandia locations. Each EMS element is further enhanced with site-specific processes and standards. Division 8000 has

  14. Sandia National Laboratories, California Environmental Management System Program Manual.

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, Barbara L.

    2011-04-01

    The Sandia National Laboratories, California (SNL/CA) Environmental Management System (EMS) Program Manual documents the elements of the site EMS Program. The SNL/CA EMS Program conforms to the International Standard on Environmental Management Systems, ISO 14001:2004and Department of Energy (DOE) Order 450.1. Sandia National Laboratories, California (SNL/CA) has maintained functional environmental programs to assist with regulatory compliance for more than 30 years. During 2005, these existing programs were rolled into a formal environmental management system (EMS) that expands beyond the traditional compliance focus to managing and improving environmental performance and stewardship practices for all site activities. An EMS is a set of inter-related elements that represent a continuing cycle of planning, implementing, evaluating, and improving processes and actions undertaken to achieve environmental policy and goals. The SNL/CA EMS Program conforms to the International Standard for Environmental Management Systems, ISO 14001:2004 (ISO 2004). The site received ISO 14001 certification in September 2006. SNL/CA's EMS Program is applicable to the Sandia, Livermore site only. Although SNL/CA operates as one organizational division of the overall Sandia National Laboratories, the EMS Program is site-specific, with site-specific objectives and targets. SNL/CA (Division 8000) benefits from the organizational structure as it provides corporate level policies, procedures, and standards, and established processes that connect to and support elements of the SNL/CA EMS Program. Additionally, SNL/CA's EMS Program benefits from two corporate functional programs (Facilities Energy Management and Fleet Services programs) that maintain responsibility for energy management and fleet services for all Sandia locations. Each EMS element is further enhanced with site-specific processes and standards. Division 8000 has several groups operating at Sandia National Laboratories

  15. Quality Management Systems in the Clinical Laboratories in Latin America

    Science.gov (United States)

    2015-01-01

    The implementation of management systems in accordance with standards like ISO 9001:2008 (1,2) in the clinical laboratories has conferred and added value of reliability and therefore a very significant input to patient safety. As we know the ISO 9001:2008 (1) a certification standard, and ISO 15189:2012 (2) an accreditation standard, both, at the time have generated institutional memory where they have been implemented, the transformation of culture focused on correct execution, control and following, evidence needed and the importance of register. PMID:27683495

  16. Mapping Soil Surface Macropores Using Infrared Thermography: An Exploratory Laboratory Study

    Science.gov (United States)

    de Lima, João L. M. P.; Abrantes, João R. C. B.; Silva, Valdemir P.; de Lima, M. Isabel P.; Montenegro, Abelardo A. A.

    2014-01-01

    Macropores and water flow in soils and substrates are complex and are related to topics like preferential flow, nonequilibrium flow, and dual-continuum. Hence, the quantification of the number of macropores and the determination of their geometry are expected to provide a better understanding on the effects of pores on the soil's physical and hydraulic properties. This exploratory study aimed at evaluating the potential of using infrared thermography for mapping macroporosity at the soil surface and estimating the number and size of such macropores. The presented technique was applied to a small scale study (laboratory soil flume). PMID:25371915

  17. Overview of groundwater and surface water standards pertinent to the Idaho National Engineering Laboratory. Revision 3

    Energy Technology Data Exchange (ETDEWEB)

    Lundahl, A.L.; Williams, S.; Grizzle, B.J.

    1995-09-01

    This document presents an overview of groundwater- and surface water-related laws, regulations, agreements, guidance documents, Executive Orders, and DOE orders pertinent to the Idaho National Engineering Laboratory. This document is a summary and is intended to help readers understand which regulatory requirements may apply to their particular circumstances. However, the document is not intended to be used in lieu of applicable regulations. Unless otherwise noted, the information in this report reflects a summary and evaluation completed July 1, 1995. This document is considered a Living Document, and updates on changing laws and regulations will be provided.

  18. Mapping soil surface macropores using infrared thermography: an exploratory laboratory study.

    Science.gov (United States)

    de Lima, João L M P; Abrantes, João R C B; Silva, Valdemir P; de Lima, M Isabel P; Montenegro, Abelardo A A

    2014-01-01

    Macropores and water flow in soils and substrates are complex and are related to topics like preferential flow, nonequilibrium flow, and dual-continuum. Hence, the quantification of the number of macropores and the determination of their geometry are expected to provide a better understanding on the effects of pores on the soil's physical and hydraulic properties. This exploratory study aimed at evaluating the potential of using infrared thermography for mapping macroporosity at the soil surface and estimating the number and size of such macropores. The presented technique was applied to a small scale study (laboratory soil flume).

  19. Decontamination of scientific and laboratory equipment with different materials and surface

    International Nuclear Information System (INIS)

    Kharita, M. H.; Khaito, M.; Wali, K.

    2003-01-01

    The process of decontamination of scientific and laboratory equipment is considered to be a very important scientific work with a good economical justification due to the expensive value of some of the contaminated equipment. This will lead to the rehabilitation of these equipment on one hand and decrease in volume of the radioactive waste on the other hand. The materials used for this process are cheap and widely available. The process developed and employed in this work showed a very good values for the decontamination factor for glass, metallic and plastic surfaces contaminated with different radioisotopes. (author)

  20. Evaluation of Surface Runoff Generation Processes Using a Rainfall Simulator: A Small Scale Laboratory Experiment

    Science.gov (United States)

    Danáčová, Michaela; Valent, Peter; Výleta, Roman

    2017-12-01

    Nowadays, rainfall simulators are being used by many researchers in field or laboratory experiments. The main objective of most of these experiments is to better understand the underlying runoff generation processes, and to use the results in the process of calibration and validation of hydrological models. Many research groups have assembled their own rainfall simulators, which comply with their understanding of rainfall processes, and the requirements of their experiments. Most often, the existing rainfall simulators differ mainly in the size of the irrigated area, and the way they generate rain drops. They can be characterized by the accuracy, with which they produce a rainfall of a given intensity, the size of the irrigated area, and the rain drop generating mechanism. Rainfall simulation experiments can provide valuable information about the genesis of surface runoff, infiltration of water into soil and rainfall erodibility. Apart from the impact of physical properties of soil, its moisture and compaction on the generation of surface runoff and the amount of eroded particles, some studies also investigate the impact of vegetation cover of the whole area of interest. In this study, the rainfall simulator was used to simulate the impact of the slope gradient of the irrigated area on the amount of generated runoff and sediment yield. In order to eliminate the impact of external factors and to improve the reproducibility of the initial conditions, the experiments were conducted in laboratory conditions. The laboratory experiments were carried out using a commercial rainfall simulator, which was connected to an external peristaltic pump. The pump maintained a constant and adjustable inflow of water, which enabled to overcome the maximum volume of simulated precipitation of 2.3 l, given by the construction of the rainfall simulator, while maintaining constant characteristics of the simulated precipitation. In this study a 12-minute rainfall with a constant intensity

  1. Laboratory insights into the detection of surface biosignatures by remote-sensing techniques

    Science.gov (United States)

    Poch, O.; Pommerol, A.; Jost, B.; Roditi, I.; Frey, J.; Thomas, N.

    2014-03-01

    With the progress of direct imaging techniques, it will be possible in the short or long-term future to retrieve more efficiently the information on the physical properties of the light reflected by rocky exoplanets (Traub et al., 2010). The search for visible-infrared absorption bands of peculiar gases (O2, CH4 etc.) in this light could give clues for the presence of life (Kaltenegger and Selsis, 2007). Even more uplifting would be the direct detection of life itself, on the surface of an exoplanet. Considering this latter possibility, what is the potential of optical remote-sensing methods to detect surface biosignatures? Reflected light from the surface of the Earth exhibits a strong surface biosignature in the form of an abrupt change of reflectance between the visible and infrared range of the spectrum (Seager et al., 2005). This spectral feature called "vegetation red-edge" is possibly the consequence of biological evolution selecting the right chemical structures enabling the plants to absorb the visible energy, while preventing them from overheating by reflecting more efficiently the infrared. Such red-edge is also found in primitive photosynthetic bacteria, cyanobacteria, that colonized the surface of the Earth ocean and continents billions of years before multicellular plants (Knacke, 2003). If life ever arose on an Earth-like exoplanet, one could hypothesize that some form of its surface-life evolves into similar photo-active organisms, also exhibiting a red-edge. In this paper, we will present our plan and preliminary results of a laboratory study aiming at precising the potentiality of remote sensing techniques in detecting such surface biosignatures. Using equipment that has been developed in our team for surface photometry studies (Pommerol 2011, Jost 2013, Pommerol 2013), we will investigate the reflectance spectra and bidirectional reflectance function of soils containing bacteria such as cyanobacteria, in various environmental conditions. We will

  2. Barium fluoride surface preparation, analysis and UV reflective coatings at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Wuest, C.R.

    1992-01-01

    Lawrence Livermore National Laboratory (LLNL) has begun a program of study on barium fluoride scintillating crystals for the Barium Fluoride Electromagnetic Calorimeter Collaboration. This program has resulted in a number of significant improvements in the mechanical processing, polishing and coating of barium fluoride crystals. Techniques have been developed using diamond-loaded pitch lapping that can produce 15 angstrom RMS surface finishes over large areas. These lapped surfaces have been shown to be crystalline using Rutherford Back-scattering (RBS). Also, special polishing fixtures have been designed based on mounting technology developed for the 1.1 m diameter optics used in LLNL's Nova Laser. These fixtures allow as many as five 25--50 cm long barium fluoride crystals to be polished and lapped at a time with the necessary tolerances for the 16,000 crystal Barium Fluoride Calorimeter. In addition, results will be presented on coating barium fluoride with UV reflective layers of magnesium fluoride and aluminum

  3. Reference Avionics Architecture for Lunar Surface Systems

    Science.gov (United States)

    Somervill, Kevin M.; Lapin, Jonathan C.; Schmidt, Oron L.

    2010-01-01

    Developing and delivering infrastructure capable of supporting long-term manned operations to the lunar surface has been a primary objective of the Constellation Program in the Exploration Systems Mission Directorate. Several concepts have been developed related to development and deployment lunar exploration vehicles and assets that provide critical functionality such as transportation, habitation, and communication, to name a few. Together, these systems perform complex safety-critical functions, largely dependent on avionics for control and behavior of system functions. These functions are implemented using interchangeable, modular avionics designed for lunar transit and lunar surface deployment. Systems are optimized towards reuse and commonality of form and interface and can be configured via software or component integration for special purpose applications. There are two core concepts in the reference avionics architecture described in this report. The first concept uses distributed, smart systems to manage complexity, simplify integration, and facilitate commonality. The second core concept is to employ extensive commonality between elements and subsystems. These two concepts are used in the context of developing reference designs for many lunar surface exploration vehicles and elements. These concepts are repeated constantly as architectural patterns in a conceptual architectural framework. This report describes the use of these architectural patterns in a reference avionics architecture for Lunar surface systems elements.

  4. A laboratory goniometer system for measuring reflectance and emittance anisotropy.

    Science.gov (United States)

    Roosjen, Peter P J; Clevers, Jan G P W; Bartholomeus, Harm M; Schaepman, Michael E; Schaepman-Strub, Gabriela; Jalink, Henk; van der Schoor, Rob; de Jong, Arjan

    2012-12-13

    In this paper, a laboratory goniometer system for performing multi-angular measurements under controlled illumination conditions is described. A commercially available robotic arm enables the acquisition of a large number of measurements over the full hemisphere within a short time span making it much faster than other goniometers. In addition, the presented set-up enables assessment of anisotropic reflectance and emittance behaviour of soils, leaves and small canopies. Mounting a spectrometer enables acquisition of either hemispherical measurements or measurements in the horizontal plane. Mounting a thermal camera allows directional observations of the thermal emittance. This paper also presents three showcases of these different measurement set-ups in order to illustrate its possibilities. Finally, suggestions for applying this instrument and for future research directions are given, including linking the measured reflectance anisotropy with physically-based anisotropy models on the one hand and combining them with field goniometry measurements for joint analysis with remote sensing data on the other hand. The speed and flexibility of the system offer a large added value to the existing pool of laboratory goniometers.

  5. An open microcomputer-based laboratory system for perceptional experimentality

    Science.gov (United States)

    Hamalainen, Ari

    A computer, equipped with hardware for acquiring data about the properties of a physical system and programs for processing that data, is a powerful tool for physics research and instruction. There is strong evidence that utilizing microcomputer-based laboratories (MBLs) in instruction can lead to significantly improved learning. The perceptional approach is a method for physics instruction, developed at the Department of Physics, University of Helsinki. Its main arguments are that the meanings of the concepts must be learnt before their formal definitions and adoption, and that learning and research are fundamentally similar concept formation processes. Applying the perceptional approach requires the ability to perform quantitative experiments, either as students' laboratory exercises or as lecture demonstrations, and to process their results. MBL tools are essential for this. In student's laboratory exercises, they reduce the routine work and leave more time for the actual learning. In lecture demonstrations, they make it possible to perform the experiments in the tight time limits. At a previous stage of the research, a set of requirements was found that the perceptional approach places on MBL systems. The primary goal of this thesis is to build a prototype of a MBL system that would fulfil these requirements. A secondary goal is to describe technical aspects of a computerized measurement system from the standpoint of educational use. The prototype was built using mostly commercial sensors and data acquisition units. The software was written with a visual programming language, designed for instrumentation applications. The prototype system was developed and tested with a set of demonstrations of various topics in the Finnish high school physics curriculum, which were implemented according to the perceptional approach. Limited usability tests were also performed. The prototype was improved, until it could perform the test demonstrations. It was found to meet the

  6. A laboratory information management system for DNA barcoding workflows.

    Science.gov (United States)

    Vu, Thuy Duong; Eberhardt, Ursula; Szöke, Szániszló; Groenewald, Marizeth; Robert, Vincent

    2012-07-01

    This paper presents a laboratory information management system for DNA sequences (LIMS) created and based on the needs of a DNA barcoding project at the CBS-KNAW Fungal Biodiversity Centre (Utrecht, the Netherlands). DNA barcoding is a global initiative for species identification through simple DNA sequence markers. We aim at generating barcode data for all strains (or specimens) included in the collection (currently ca. 80 k). The LIMS has been developed to better manage large amounts of sequence data and to keep track of the whole experimental procedure. The system has allowed us to classify strains more efficiently as the quality of sequence data has improved, and as a result, up-to-date taxonomic names have been given to strains and more accurate correlation analyses have been carried out.

  7. New laboratory methods to study tooth surface coverage and interproximal plaque control by dentifrice products.

    Science.gov (United States)

    Xu, Tao; Herles, Susan M; Barnes, Virginia M

    2004-01-01

    To develop and test an in vitro tooth model for use in conjunction with laboratory methods to study interproximal effects and efficacy of dentifrices. The application of the model should offer visual evaluation of dentifrice coverage of the tooth surface, and measure dental plaque control at posterior interdental spaces with a dentifrice. The dentifrice products tested with the model were: Colgate Total 2 in 1 Toothpaste and Mouthwash (CTTM), Colgate Total dentifrice (CTD), and Colgate Regular dentifrice (CRD). Extracted human posterior teeth were disinfected, cleaned, aligned, and mounted in denture acrylic. In the area coverage method, tooth surface coverage and penetration of two different forms of dentifrice products (CTTM and CRD) were compared using digital photography. In the interproximal plaque control method, the teeth were coated with human saliva and incubated anaerobically with a mixture of representative oral bacteria for six hours at 37 degrees C. In vitro dental plaque was assessed after brushing the facial surface with one of the three dentifrice products using a clinical plaque scoring index. The area coverage method demonstrated that both dentifrice products tested covered approximately 70% of the facial tooth surface; the CTTM dentifrice coverage on the lingual tooth surface was significantly higher than the coverage for the CRD dentifrice. With the interproximal plaque control method, in the presence of an active ingredient, the CTTM dentifrice had equivalent efficacy to the CTD dentifrice. Both CTTM and CTD were significantly superior to the CRD for interproximal dental plaque control. Using the developed tooth model, two assessment methods have been shown to have the potential to demonstrate tooth surface coverage, and to assess the potential efficacy of a dentifrice for the control of interproximal dental plaque. This process can indicate potential clinical evaluation of an oral care product, and support clinical findings with controlled

  8. Los Alamos National Laboratory's Mobile Real Time Radiography System

    International Nuclear Information System (INIS)

    Vigil, J.; Taggart, D.; Betts, S.; Mendez, J.; Rael, C.; Martinez, F.

    1997-01-01

    A 450-KeV Mobile Real Time Radiography (RTR) System was delivered to Los Alamos National Laboratory (LANL) in January 1996. It was purchased to inspect containers of radioactive waste produced at (LANL). Since its delivery it has been used to radiograph greater than 600 drums of radioactive waste at various LANL sites. It has the capability of inspecting waste containers of various sizes. It has three independent X-Ray acquisition formats. The primary system used is a 12 in. image intensifier, the second is a 36 in. linear diode array (LDA) and the last is an open system. It is fully self contained with on board generator, HVAC and a fire suppression system. It is on a 53 ft long X 8 ft. wide X 14 ft. high trailer that can be moved over any highway requiring only a easily obtainable overweight permit because it weighs approximately 38 tons. It was built to conform to industry standards for a cabinet system which does not require an exclusion zone. The fact that this unit is mobile has allowed us to operate where the waste is stored, rather than having to move the waste to a fixed facility

  9. Monitoring and information management system at the Underground Research Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Strobel, G.S.; Chernis, P.J.; Bushman, A.T.; Spinney, M.H.; Backer, R.J. [Atomic Energy of Canada Limited, Pinawa, Manitoba (Canada)

    1996-07-01

    Atomic Energy of Canada Limited (AECL) has developed a customer oriented monitoring and information management system at the Underground Research Laboratory (URL) near Lac du Bonnet, Manitoba. The system is used to monitor instruments and manage, process, and distribute data. It consists of signal conditioners and remote loggers, central schedule and control systems, computer aided design and drafting work centres, and the communications linking them. The monitoring and communications elements are designed to meet the harsh demands of underground conditions while providing accurate monitoring of sensitive instruments to rigorous quality assured specifications. These instruments are used for testing of the concept for the deep geological disposal of nuclear fuel waste as part of the Canadian Nuclear Fuel Waste Management Program. Many of the tests are done in situ and at full-scale. The monitoring and information management system services engineering, research, and support staff working to design, develop, and demonstrate and present the concept. Experience gained during development of the monitoring and information management system at the URL, can be directly applied at the final disposal site. (author)

  10. Monitoring and information management system at the Underground Research Laboratory

    International Nuclear Information System (INIS)

    Strobel, G.S.; Chernis, P.J.; Bushman, A.T.; Spinney, M.H.; Backer, R.J.

    1996-01-01

    Atomic Energy of Canada Limited (AECL) has developed a customer oriented monitoring and information management system at the Underground Research Laboratory (URL) near Lac du Bonnet, Manitoba. The system is used to monitor instruments and manage, process, and distribute data. It consists of signal conditioners and remote loggers, central schedule and control systems, computer aided design and drafting work centres, and the communications linking them. The monitoring and communications elements are designed to meet the harsh demands of underground conditions while providing accurate monitoring of sensitive instruments to rigorous quality assured specifications. These instruments are used for testing of the concept for the deep geological disposal of nuclear fuel waste as part of the Canadian Nuclear Fuel Waste Management Program. Many of the tests are done in situ and at full-scale. The monitoring and information management system services engineering, research, and support staff working to design, develop, and demonstrate and present the concept. Experience gained during development of the monitoring and information management system at the URL, can be directly applied at the final disposal site. (author)

  11. Los Alamos Scientific Laboratory long-range alarm system

    International Nuclear Information System (INIS)

    DesJardin, R.; Machanik, J.

    1980-01-01

    The Los Alamos Scientific Laboratory (LASL) Long-Range Alarm System is described. The last few years have brought significant changes in the Department of Energy regulations for protection of classified documents and special nuclear material. These changes in regulations have forced a complete redesign of the LASL security alarm system. LASL covers many square miles of varying terrain and consists of separate technical areas connected by public roads and communications. A design study over a period of 2 years produced functional specifications for a distributed intelligence, expandable alarm system that will handle 30,000 alarm points from hundreds of data concentrators spread over a 250-km 2 area. Emphasis in the design was on nonstop operation, data security, data communication, and upward expandability to incorporate fire alarms and the computer-aided dispatching of security and fire vehicles. All aspects of the alarm system were to be fault tolerant from the central computer system down to but not including the individual data concentrators. Redundant communications lines travel over public domain from the alarmed area to the central alarm station

  12. Flat Surface Damage Detection System (FSDDS)

    Science.gov (United States)

    Williams, Martha; Lewis, Mark; Gibson, Tracy; Lane, John; Medelius, Pedro; Snyder, Sarah; Ciarlariello, Dan; Parks, Steve; Carrejo, Danny; Rojdev, Kristina

    2013-01-01

    The Flat Surface Damage Detection system (FSDDS} is a sensory system that is capable of detecting impact damages to surfaces utilizing a novel sensor system. This system will provide the ability to monitor the integrity of an inflatable habitat during in situ system health monitoring. The system consists of three main custom designed subsystems: the multi-layer sensing panel, the embedded monitoring system, and the graphical user interface (GUI). The GUI LABVIEW software uses a custom developed damage detection algorithm to determine the damage location based on the sequence of broken sensing lines. It estimates the damage size, the maximum depth, and plots the damage location on a graph. Successfully demonstrated as a stand alone technology during 2011 D-RATS. Software modification also allowed for communication with HDU avionics crew display which was demonstrated remotely (KSC to JSC} during 2012 integration testing. Integrated FSDDS system and stand alone multi-panel systems were demonstrated remotely and at JSC, Mission Operations Test using Space Network Research Federation (SNRF} network in 2012. FY13, FSDDS multi-panel integration with JSC and SNRF network Technology can allow for integration with other complementary damage detection systems.

  13. Monitoring System for ALICE Surface Areas

    CERN Document Server

    Demirbasci, Oguz

    2016-01-01

    I have been at CERN for 12 weeks within the scope of Summer Student Programme working on a monitoring system project for surface areas of the ALICE experiment during this period of time. The development and implementation of a monitoring system for environmental parameters in the accessible areas where a cheap hardware setup can be deployed were aim of this project. This report explains how it was developed by using Arduino, Raspberry PI, WinCC OA and DIM protocol.

  14. Dry cooling systems with plastic surfaces

    International Nuclear Information System (INIS)

    Roma, Carlo; Leonelli, Vincenzo

    1975-01-01

    Research and experiments made on dry cooling systems with plastic surfaces are described. The demonstration program planned in Italy for a 100Gcal/h dry cooling system is exposed, and an installation intended for a large 1300Mwe nuclear power station is described with reference to the assembly (exploitation and maintenance included). The performance and economic data relating to this installation are also exposed [fr

  15. ARM Surface Meteorology Systems Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Ritsche, MT

    2011-03-08

    The ARM Surface Meteorology Systems consist mainly of conventional in situ sensors that obtain a defined “core” set of measurements. The core set of measurements is: Barometric Pressure (kPa), Temperature (°C), Relative Humidity (%), Arithmetic-Averaged Wind Speed (m/s), Vector-Averaged Wind Speed (m/s), and Vector-Averaged Wind Direction (deg).

  16. Regolith Advanced Surface Systems Operations Robot Excavator

    Science.gov (United States)

    Mueller, Robert P.; Smith, Jonathan D.; Ebert, Thomas; Cox, Rachel; Rahmatian, Laila; Wood, James; Schuler, Jason; Nick, Andrew

    2013-01-01

    The Regolith Advanced Surface Systems Operations Robot (RASSOR) excavator robot is a teleoperated mobility platform with a space regolith excavation capability. This more compact, lightweight design (<50 kg) has counterrotating bucket drums, which results in a net-zero reaction horizontal force due to the self-cancellation of the symmetrical, equal but opposing, digging forces.

  17. Automatic exposure system for radioactive source at teaching laboratory

    International Nuclear Information System (INIS)

    Seren, Maria Emilia G.; Gaal, Vladmir; Morais, Sergio Luiz de; Rodrigues, Varlei

    2013-01-01

    The development of Compton Scattering experiment, studied by undergraduate students of the Medical Physics course at the Universidade Estadual de Campinas (UNICAMP), takes place in the Medical Physics Teaching Laboratory, belonging to the Gleb Wataghin Physics Institute (IFGW/UNICAMP). The experiment consists of a fixed 137 Cs radioactive source, with current activity of 610.5 MBq and a scintillation detector that turns around the center of the system whose function is to detect the scattered photons spectrum by a scatter object (target). The 137 Cs source is stored in a lead shield with a collimating window for the gamma radiation emitted with energy of 0.662 MeV. This source is exposed only when an attenuation barrier protecting the collimating window is opened. The process of opening and closing the attenuation barrier may deliver a radiation dose to users when done manually. Considering the stochastic harmful effects of ionizing radiation, the goal of this project was to develop an automatic exposure system of the radioactive source, in order to reduce the radiation dose received during the Compton Scattering experiment. The developed system is micro controlled and performs standard operating routines, responding to emergencies. Furthermore, an electromagnetic lock enables quick closing of the barrier by gravity, in case of interruption of the electrical current circuit. Besides reducing the total dose to lab users, the system adds more security to the routine, since it limits the access to the radioactive source and prevents accidental exposure. (author)

  18. The Laboratory for Laser Energetics’ Hydrogen Isotope Separation System

    Energy Technology Data Exchange (ETDEWEB)

    Shmayda, W.T., E-mail: wshm@lle.rochester.edu; Wittman, M.D.; Earley, R.F.; Reid, J.L.; Redden, N.P.

    2016-11-01

    The University of Rochester’s Laboratory for Laser Energetics has commissioned a hydrogen Isotope Separation System (ISS). The ISS uses two columns—palladium on kieselguhr and molecular sieve—that act in a complementary manner to separate the hydrogen species by mass. The 4-sL per day throughput system is compact and has no moving parts. The columns and the attendant gas storage and handling subsystems are housed in a 0.8 -m{sup 3} glovebox. The glovebox uses a helium cover gas that is continuously processed to extract oxygen and water vapor that permeates through the glovebox gloves and any tritium that is released while attaching or detaching vessels to add feedstock to or drawing product from the system. The isotopic separation process is automated and does not require manual intervention. A total of 315 TBq of tritium was extracted from 23.6 sL of hydrogen with tritium purities reaching 99.5%. Deuterium was the sole residual component in the processed gas. Raffinate contained 0.2 TBq of activity was captured for reprocessing. The total emission from the system to the environment was 0.4 GBq over three weeks.

  19. Control code for laboratory adaptive optics teaching system

    Science.gov (United States)

    Jin, Moonseob; Luder, Ryan; Sanchez, Lucas; Hart, Michael

    2017-09-01

    By sensing and compensating wavefront aberration, adaptive optics (AO) systems have proven themselves crucial in large astronomical telescopes, retinal imaging, and holographic coherent imaging. Commercial AO systems for laboratory use are now available in the market. One such is the ThorLabs AO kit built around a Boston Micromachines deformable mirror. However, there are limitations in applying these systems to research and pedagogical projects since the software is written with limited flexibility. In this paper, we describe a MATLAB-based software suite to interface with the ThorLabs AO kit by using the MATLAB Engine API and Visual Studio. The software is designed to offer complete access to the wavefront sensor data, through the various levels of processing, to the command signals to the deformable mirror and fast steering mirror. In this way, through a MATLAB GUI, an operator can experiment with every aspect of the AO system's functioning. This is particularly valuable for tests of new control algorithms as well as to support student engagement in an academic environment. We plan to make the code freely available to the community.

  20. Quantifying soil surface photolysis under conditions simulating water movement in the field: a new laboratory test design.

    Science.gov (United States)

    Hand, Laurence H; Nichols, Carol; Kuet, Sui F; Oliver, Robin G; Harbourt, Christopher M; El-Naggar, Essam M

    2015-10-01

    Soil surface photolysis can be a significant dissipation pathway for agrochemicals under field conditions, although it is assumed that such degradation ceases once the agrochemical is transported away from the surface following rainfall or irrigation and subsequent drainage of soil porewater. However, as both downward and upward water movements occur under field conditions, relatively mobile compounds may return to the surface, prolonging exposure to ultraviolet light and increasing the potential for degradation by photolysis. To test this hypothesis, a novel experimental system was used to quantify the contribution of photolysis to the overall dissipation of a new herbicide, bicyclopyrone, under conditions that mimicked field studies more closely than the standard laboratory test guidance. Soil cores were taken from 3 US field study sites, and the surfaces were treated with [(14) C]-bicyclopyrone. The radioactivity was redistributed throughout the cores using a simulated rainfall event, following which the cores were incubated under a xenon-arc lamp with continuous provision of moisture from below and a wind simulator to induce evaporation. After only 2 d, most of the test compound had returned to the soil surface. Significantly more degradation was observed in the irradiated samples than in a parallel dark control sample. Degradation rates were very similar to those observed in both the thin layer photolysis study and the field dissipation studies and significantly faster than in the soil metabolism studies conducted in the dark. Thus, for highly soluble, mobile agrochemicals, such as bicyclopyrone, photolysis is not terminated permanently by rainfall or irrigation but can resume following transport to the surface in evaporating water. © 2015 SETAC.

  1. Novel surface measurement system reading cost savings

    Energy Technology Data Exchange (ETDEWEB)

    Sword, M.

    1996-05-01

    A new state-of-the-art data acquisition system for the oil and natural gas industries is being marketed by OPSCO`92 Industries Ltd. The unit is portable, it measures surface data which is calibrated to bottom-hole conditions and designed to measure temperature and pressure information without the necessity of sending testing equipment downhole. The Surface Data System (SDS) uses silicon-crystal technology, is mounted in a suitcase size carrying case, and runs off a 12-volt battery enclosure which can be backed up by a small solar panel. The first generation system can handle 16 different channels of information input on a laptop computer. Pressure, pressure differential, temperature, frequency and pulse signals for flow meter measurements are handled by standard sensors. Areas of application include build-up and fall-off tests, pipeline evaluation, pre-frac tests, underbalanced drilling and gas well evaluation. 1 fig., 1 photo.

  2. New radionuclide specific laboratory detection system for metallurgical industry

    International Nuclear Information System (INIS)

    Burianova, L.; Solc, J.; Dryak, P.; Moser, H.; Branger, T.; Garcia-Torano, E.; Peyres, V.; Capogni, M.; Luca, A.; Vodenik, B.; Oliveira, C.; Portugal, L.; Tzika, F.; Lutter, G.; Szucs, L.; Dziel, T.; Burda, O.; Dirk, A.; Martinkovic, J.; Sliskonen, T.; Mattila, A.

    2014-01-01

    One of the main outputs of the European Metrology Research Programme (EMRP) project 'Ionising radiation metrology for the metallurgical industry' (MetroMetal) was the recommendation on a novel spectrometric detection system optimized for the measurement of radioactivity in metallurgical samples. The recommended system, prototypes of which were constructed at two project partner's laboratories, was characterized by using Monte Carlo (MC) simulations. Six different MC codes were used to model the system and a range of cylindrical samples of cast steel, slag and fume dust. The samples' shape, density, and elemental composition were the same as the ones of the calibration standards developed within the project to provide traceability to end-users. The MC models were used to calculate full-energy peak and total detection efficiencies as well as true coincidence summing correction (TCSC) factors for selected radionuclides of interest in the metallurgical industry: 60 Co, 137 Cs, 192 Ir, 214 Bi, 214 Pb, and 208 Tl. The MC codes were compared to each other on the basis of the calculated detection efficiencies and TCSC factors. In addition, a 'Procedural guide for calculation of TCSC factors for samples in metallurgical industry' was developed for end-users. The TCSC factors reached in certain cases up to 32% showing that the summing effects are of high importance in the close measurement geometries met in routine analysis of metallurgical samples. (authors)

  3. Evaluation of the Earth Systems Research Laboratory's global Observing System Simulation Experiment system

    Directory of Open Access Journals (Sweden)

    Nikki C. Privé

    2013-03-01

    Full Text Available An Observing System Simulation Experiment (OSSE system has been implemented at the National Oceanographic and Atmospheric Administration Earth Systems Research Laboratory in the US as part of an international Joint OSSE effort. The setup of the OSSE consists of a Nature Run from a 13-month free run of the European Center for Medium-Range Weather Forecasts operational model, synthetic observations developed at the National Centers for Environmental Prediction (NCEP and the National Aeronautics and Space Administration Global Modelling and Assimilation Office, and an operational version of the NCEP Gridpoint Statistical Interpolation data assimilation and Global Forecast System numerical weather prediction model. Synthetic observations included both conventional observations and the following radiance observations: AIRS, AMSU-A, AMSU-B, HIRS2, HIRS3, MSU, GOES radiance and OSBUV. Calibration was performed by modifying the error added to the conventional synthetic observations to achieve a match between data denial impacts on the analysis state in the OSSE system and in the real data system. Following calibration, the performance of the OSSE system was evaluated in terms of forecast skill scores and impact of observations on forecast fields.

  4. Energy-related environmental computer graphics systems in the Department of Energy Laboratories

    Energy Technology Data Exchange (ETDEWEB)

    None

    1978-02-01

    Computerized graphics techniques available in the Department of Energy's national laboratories for use in the environmental aspects of energy such as land use planning (including siting), and regional studies, environmental impact assessment are discussed. Areas covered include: computer graphics; mapping/cartography; image processing; animation; computer movies; satellite graphics; surface representation; land use analysis; pattern recognition; demographics analysis; ecological analysis; and biomedical applications. Descriptions of each graphics system included should be sufficient for a potential user to determine its possible use to him. Further, information is available by writing or telephoning the indicated contact person.

  5. Surface-wave and refraction tomography at the FACT Site, Sandia National Laboratories, Albuquerque, New Mexico.

    Energy Technology Data Exchange (ETDEWEB)

    Abbott, Robert E.; Bartel, Lewis Clark; Pullammanappallil, Satish (Optim, Inc., Reno, NV); Engler, Bruce Phillip

    2006-08-01

    We present a technique that allows for the simultaneous acquisition and interpretation of both shear-wave and compressive-wave 3-D velocities. The technique requires no special seismic sources or array geometries, and is suited to studies with small source-receiver offsets. The method also effectively deals with unwanted seismic arrivals by using the statistical properties of the data itself to discriminate against spurious picks. We demonstrate the technique with a field experiment at the Facility for Analysis, Calibration, and Testing at Sandia National Laboratories, Albuquerque, New Mexico. The resulting 3-D shear-velocity and compressive-velocity distributions are consistent with surface geologic mapping. The averaged velocities and V{sub p}/V{sub s} ratio in the upper 30 meters are also consistent with examples found in the scientific literature.

  6. Baobab Laboratory Information Management System: Development of an Open-Source Laboratory Information Management System for Biobanking.

    Science.gov (United States)

    Bendou, Hocine; Sizani, Lunga; Reid, Tim; Swanepoel, Carmen; Ademuyiwa, Toluwaleke; Merino-Martinez, Roxana; Meuller, Heimo; Abayomi, Akin; Christoffels, Alan

    2017-04-01

    A laboratory information management system (LIMS) is central to the informatics infrastructure that underlies biobanking activities. To date, a wide range of commercial and open-source LIMSs are available and the decision to opt for one LIMS over another is often influenced by the needs of the biobank clients and researchers, as well as available financial resources. The Baobab LIMS was developed by customizing the Bika LIMS software ( www.bikalims.org ) to meet the requirements of biobanking best practices. The need to implement biobank standard operation procedures as well as stimulate the use of standards for biobank data representation motivated the implementation of Baobab LIMS, an open-source LIMS for Biobanking. Baobab LIMS comprises modules for biospecimen kit assembly, shipping of biospecimen kits, storage management, analysis requests, reporting, and invoicing. The Baobab LIMS is based on the Plone web-content management framework. All the system requirements for Plone are applicable to Baobab LIMS, including the need for a server with at least 8 GB RAM and 120 GB hard disk space. Baobab LIMS is a server-client-based system, whereby the end user is able to access the system securely through the internet on a standard web browser, thereby eliminating the need for standalone installations on all machines.

  7. System for removing contaminated surface layers

    International Nuclear Information System (INIS)

    Yoshikawa, Kozo.

    1987-04-01

    The object of the present invention is to offer a new type of useful decontamination system, with which the contaminated surface layers can be removed effectively by injection of such solid microparticles. Liquid carbon dioxide is passed from a liquid carbon dioxide tank via the carbon dioxide supply line into the system for injecting solid carbon dioxide particles. Part of the liquid carbon dioxide introduced into the system is converted to solid carbon dioxide particles by the temperature drop resulting from adiabatic expansion in the carbon dioxide expansion space of the injection system. The solid carbon dioxide particles reach the injection nozzle, which is connected through the expansion space. The carbon dioxide microparticles are further cooled and accelerated by nitrogen gas injected from the nitrogen gas nozzle at the tip of the nitrogen gas supply line, which is connected to a liquid nitrogen tank. The cooled and accelerated solid carbon dioxide microparticles are injected from the injection nozzle for the solid carbon dioxide and directed against the contaminated surface to be cleaned, and, as a result, the surface contamination is removed

  8. SURFACE INDUSTRIAL HVAC SYSTEM DESCRIPTION DOCUMENT

    Energy Technology Data Exchange (ETDEWEB)

    M.M. Ansari

    2005-04-05

    The purpose of this system description document (SDD) is to establish requirements that drive the design of the surface industrial heating, ventilation, and air-conditioning (HVAC) system and its bases to allow the design effort to proceed to license application. This SDD will be revised at strategic points as the design matures. This SDD identifies the requirements and describes the system design, as it currently exists, with emphasis on attributes of the design provided to meet the requirements. This SDD is an engineering tool for design control; accordingly, the primary audience and users are design engineers. This SDD is part of an iterative design process. It leads the design process with regard to the flowdown of upper tier requirements onto the system. Knowledge of these requirements is essential to performing the design process. The SDD follows the design with regard to the description of the system. The description that provided in this SDD reflects the current results of the design process.

  9. Environmental Molecular Sciences Laboratory Operations System: Version 4.0 - system requirements specification

    Energy Technology Data Exchange (ETDEWEB)

    Kashporenko, D.

    1996-07-01

    This document is intended to provide an operations standard for the Environmental Molecular Sciences Laboratory OPerations System (EMSL OPS). It is directed toward three primary audiences: (1) Environmental Molecular Sciences Laboratory (EMSL) facility and operations personnel; (2) laboratory line managers and staff; and (3) researchers, equipment operators, and laboratory users. It is also a statement of system requirements for software developers of EMSL OPS. The need for a finely tuned, superior research environment as provided by the US Department of Energy`s (DOE) Environmental Molecular Sciences Laboratory has never been greater. The abrupt end of the Cold War and the realignment of national priorities caused major US and competing overseas laboratories to reposition themselves in a highly competitive research marketplace. For a new laboratory such as the EMSL, this means coming into existence in a rapidly changing external environment. For any major laboratory, these changes create funding uncertainties and increasing global competition along with concomitant demands for higher standards of research product quality and innovation. While more laboratories are chasing fewer funding dollars, research ideas and proposals, especially for molecular-level research in the materials and biological sciences, are burgeoning. In such an economically constrained atmosphere, reduced costs, improved productivity, and strategic research project portfolio building become essential to establish and maintain any distinct competitive advantage. For EMSL, this environment and these demands require clear operational objectives, specific goals, and a well-crafted strategy. Specific goals will evolve and change with the evolution of the nature and definition of DOE`s environmental research needs. Hence, EMSL OPS is designed to facilitate migration of these changes with ease into every pertinent job function, creating a facile {open_quotes}learning organization.{close_quotes}

  10. Terrestrial aurora: astrophysical laboratory for anomalous abundances in stellar systems

    Directory of Open Access Journals (Sweden)

    I. Roth

    2014-02-01

    Full Text Available The unique magnetic structure of the terrestrial aurora as a conduit of information between the ionosphere and magnetosphere can be utilized as a laboratory for physical processes at similar magnetic configurations and applied to various evolutionary phases of the solar (stellar system. The most spectacular heliospheric abundance enhancement involves the 3He isotope and selective heavy elements in impulsive solar flares. In situ observations of electromagnetic waves on active aurora are extrapolated to flaring corona in an analysis of solar acceleration processes of 3He, the only element that may resonate strongly with the waves, as well as heavy ions with specific charge-to-mass ratios, which may resonate weaker via their higher gyroharmonics. These results are applied to two observed anomalous astrophysical abundances: (1 enhanced abundance of 3He and possibly 13C in the late stellar evolutionary stages of planetary nebulae; and (2 enhanced abundance of the observed fossil element 26Mg in meteorites as a decay product of radioactive 26Al isotope due to interaction with the flare-energized 3He in the early solar system.

  11. Regional Educational Laboratory Electronic Network Phase 2 System

    Science.gov (United States)

    Cradler, John

    1995-01-01

    The Far West Laboratory in collaboration with the other regional educational laboratories is establishing a regionally coordinated telecommunication network to electronically interconnect each of the ten regional laboratories with educators and education stakeholders from the school to the state level. For the national distributed information database, each lab is working with mid-level networks to establish a common interface for networking throughout the country and include topics of importance to education reform as assessment and technology planning.

  12. Laboratory evaluation of the effect of toothbrushing on surface gloss of resin composites.

    Science.gov (United States)

    Lefever, Dorien; Krejci, Ivo; Ardu, Stefano

    2014-02-01

    To determine changes in surface gloss of different composite materials after laboratory toothbrushing simulation. 40 specimens were fabricated for each material (Filtek Supreme XTE, Renamel, Empress Direct, Gradia Direct, Edelweiss, G-aenial, Venus Pearl and Venus Diamond) and polished with 120-, 220-, 500-, 1200-, 2400- and 4000- grit SiC abrasive paper, respectively. Gloss measurements were made with a glossmeter prior to testing procedures and then subjected to simulated toothbrushing for 5, 15, 30 and 60 minutes by means of an electrical toothbrush with a pressure of 2N while being immersed in a 50 RDA toothpaste slurry. Four samples per group were analyzed under SEM immediately after polishing procedures and four samples after 60 minutes simulated toothbrushing in order to evaluate the causes of the gloss decrease. Human enamel was the control group. Statistical analysis was performed using Kruskal Wallis and Tukey's post-hoc test (P < 0.05). Resin composite initial gloss values ranged from 78.2 to 100.5 at baseline to 13.8 to 62.4 after 1 hour of brushing. Highest gloss values were obtained by Filtek Supreme XTE and Renamel (P < 0.05), followed by Empress Direct. Lowest values were obtained with Venus Diamond, Venus Pearl, G-aenial and Edelweiss. Human enamel was the only material which maintained its gloss throughout the brushing procedure (110.4 after 60 minutes). SEM analysis revealed different patterns of surface degradation dependant on the material.

  13. Integrated Verification Experiment data collected as part of the Los Alamos National Laboratory`s Source Region Program. Appendix B: Surface ground motion

    Energy Technology Data Exchange (ETDEWEB)

    Weaver, T.A.; Baker, D.F.; Edwards, C.L.; Freeman, S.H.

    1993-10-01

    Surface ground motion was recorded for many of the Integrated Verification Experiments using standard 10-, 25- and 100-g accelerometers, force-balanced accelerometers and, for some events, using golf balls and 0.39-cm steel balls as surface inertial gauges (SIGs). This report contains the semi-processed acceleration, velocity, and displacement data for the accelerometers fielded and the individual observations for the SIG experiments. Most acceleration, velocity, and displacement records have had calibrations applied and have been deramped, offset corrected, and deglitched but are otherwise unfiltered or processed from their original records. Digital data for all of these records are stored at Los Alamos National Laboratory.

  14. Laboratory evaluations of elmex inter X toothbrushes for interproximal access efficacy and posterior tooth surface cleaning.

    Science.gov (United States)

    Yankell, S L; Shi, X; Emling, R C

    2002-01-01

    Laboratory methods have been developed to evaluate the ability of toothbrush bristles to remove artificial plaque deposits at interproximal sites (Interproximal Access Efficacy; IAE) and on distal tooth surfaces (Posterior Tooth Surface Cleaning; PTSC). In the testing performed for this study, six toothbrushes were evaluated. These were: elmex inter X Sensitive; elmex inter X Sensitive Short Head; elmex inter X medium; elmex inter X Medium Short Head; Oral-B Cross Action 40 medium; and the ADA reference standard toothbrush. Six toothbrushes of each design were tested four times under wet brushing conditions in all assays. In the IAE studies, toothbrushing was conducted using a vertical or horizontal brushing motion, simulated anterior or posterior teeth, and a brushing weight of 250 g. The bristles were placed at a 90 degree angle to the tooth surface, and brushing was performed for 15 seconds at two strokes per second with 50 mm strokes. IAE was recorded as the maximum width of simulated plaque deposit removed. For the PTSC evaluations, a horizontal brushing motion was used on posterior tooth shapes, with a 250 g brushing pressure for ten seconds. PTSC was determined as the maximum measurement of artificial plaque deposit removed from the mid-facial area to the maximum post-distal area of the most posterior simulated tooth shape. All data were assessed with ANOVA and the post hoc Tukey test. In the individual IAE tests, with vertical or horizontal brushing on anterior and posterior simulated teeth, and on overall IAE mean values, the four elmex inter X toothbrushes were significantly higher (p PTSC values for all toothbrushes were significantly higher (p PTSC. All elmex inter X brushes were statistically significantly higher (p PTSC compared to the PTSC mean values of the other elmex inter X products tested.

  15. Usability evaluation of Laboratory and Radiology Information Systems integrated into a hospital information system.

    Science.gov (United States)

    Nabovati, Ehsan; Vakili-Arki, Hasan; Eslami, Saeid; Khajouei, Reza

    2014-04-01

    This study was conducted to evaluate the usability of widely used laboratory and radiology information systems. Three usability experts independently evaluated the user interfaces of Laboratory and Radiology Information Systems using heuristic evaluation method. They applied Nielsen's heuristics to identify and classify usability problems and Nielsen's severity rating to judge their severity. Overall, 116 unique heuristic violations were identified as usability problems. In terms of severity, 67 % of problems were rated as major and catastrophic. Among 10 heuristics, "consistency and standards" was violated most frequently. Moreover, mean severity of problems concerning "error prevention" and "help and documentation" heuristics was higher than of the others. Despite widespread use of specific healthcare information systems, they suffer from usability problems. Improving the usability of systems by following existing design standards and principles from the early phased of system development life cycle is recommended. Especially, it is recommended that the designers design systems that inhibit the initiation of erroneous actions and provide sufficient guidance to users.

  16. Remote Laboratory and Animal Behaviour: An Interactive Open Field System

    Science.gov (United States)

    Fiore, Lorenzo; Ratti, Giovannino

    2007-01-01

    Remote laboratories can provide distant learners with practical acquisitions which would otherwise remain precluded. Our proposal here is a remote laboratory on a behavioural test (open field test), with the aim of introducing learners to the observation and analysis of stereotyped behaviour in animals. A real-time video of a mouse in an…

  17. A Multi-User Remote Academic Laboratory System

    Science.gov (United States)

    Barrios, Arquimedes; Panche, Stifen; Duque, Mauricio; Grisales, Victor H.; Prieto, Flavio; Villa, Jose L.; Chevrel, Philippe; Canu, Michael

    2013-01-01

    This article describes the development, implementation and preliminary operation assessment of Multiuser Network Architecture to integrate a number of Remote Academic Laboratories for educational purposes on automatic control. Through the Internet, real processes or physical experiments conducted at the control engineering laboratories of four…

  18. Liposomal drug delivery system from laboratory to clinic

    Directory of Open Access Journals (Sweden)

    Kshirsagar N

    2005-01-01

    Full Text Available The main objective of drug delivery systems is to deliver a drug effectively, specifically to the site of action and to achieve greater efficacy and minimise the toxic effects compared to conventional drugs. Amongst various carrier systems, liposomes have generated a great interest because of their versatility. Liposomes are vesicular concentric bilayered structures, which are biocompatible, biodegradable and nonimmumnogenic. They can control the delivery of drugs by targeting the drug to the site of action or by site avoidance drug delivery or by prolonged circulation of drugs. Amphotericin B (Amp B remains the drug of choice in most systemic mycoses and also as a second line treatment for Kala azar. However, its toxic effects often limit its use. Although the liposome delivery system has been tried for several drugs, only a few have been used in patients due to the slow development of necessary large-scale pharmaceutical procedures. This paper reviews the development of the technique for liposomal Amphotericin B (L-Amp-LRC-1, FungisomeTM drug delivery system in our laboratory in collaboration with the department of Biochemistry, Delhi University in India and proving the safety and efficacy of this preparation in clinical practice. It also attempts to compare the efficacy and benefits of our product for Indian patients with those of similar products and it includes facts from the publications that flowed from our work. As compared to conventional Amp B, Fungisome is infused over a much shorter period requiring a smaller volume and no premedication. It was found to be safe in patients who had developed serious unacceptable toxicity with conventional Amp B. In renal transplant patients, Fungisome did not produce any nephrotoxicity. Fungisome is effective in fungal infections resistant to fluconazole, conventional Amp B and in virgin and resistant cases of visceral leishmaniasis. The cost of any drug is of great significance, especially in India

  19. Vacuum Systems Consensus Guideline for Department of Energy Accelerator Laboratories

    International Nuclear Information System (INIS)

    Casey, R.; Collins, J.; Haas, E.; Hseuh, H.; Jobe, R.; Kane, S.; Ladd, P.; Lessard, E.; Sharma, S.; Oils, D.; Pushka, D.; Toter, W.

    2008-01-01

    inspections of materials, in-process fabrications, non-destructive tests, and acceptance test. (3) Documentation, traceability, and accountability must be maintained for each unique pressure vessel or system, including descriptions of design, pressure conditions, testing, inspection, operation, repair, and maintenance. The purpose of this guideline is to establish a set of expectations and recommendations which will satisfy the requirements for vacuum vessels in general and particularly when an equivalent level of safety as required by 10 CFR 851 must be provided. It should be noted that these guidelines are not binding on DOE Accelerator Laboratories and that other approaches may be equally acceptable in addressing the Part 851 requirements

  20. Surface sedimentation at permeable pavement systems

    DEFF Research Database (Denmark)

    Støvring, Jan; Dam, Torben; Jensen, Marina Bergen

    2018-01-01

    of restorative cleaning (RC), nine recently built PP systems were tested for their infiltration capacity with and without restorative cleaning (RC) over an interval of 12–14.5 months. The results were related to each site’s unique history of sedimentation. RC significantly improved permeability, but when...... revisited after approximately one year, the permeability of cleaned surfaces was not significantly better for the RC spots than from their uncleaned neighbouring areas. Relating permeability to the contextual issues revealed that PP perimeter, adjacent bare soil and mismanagement strongly affected...... the sedimentation process. At two of the sites, sedimentation processes were so advanced that surface permeability was below the level of service (five-year design storm)....

  1. Laboratory investigations of the heat and momentum transfer in the stably stratified air turbulent boundary layer above the wavy surface

    Science.gov (United States)

    Sergeev, Daniil; Troitskaya, Yuliya; Vdovin, Maxim

    2015-04-01

    Investigation of small scale transfer processes between the ocean and atmosphere in the boundary and its parameterization on the meteorological conditions (wind and surface waves parameters) is very important for weather forecasts modeling [1]. The accuracy of the predictions taking in to account the so named bulk-formulas strongly depends on the quality empirical data. That is why the laboratory modeling sometimes is preferable (see [2]) then in situ measurements for obtaining enough ensembles of the data with a good accuracy in control conditions, first of all in a case of severe conditions (strong winds with intensive wave breaking and sprays generation). In this investigation laboratory modeling was performed on the Thermostratified Wind-Wave Channel of the IAP RAS (see. [3]). Experiments were carried out for the wind speeds up to 18.5 m/s (corresponding the equivalent 10-m wind speed 30 m/s). For the possibility of varying parameters of surface roughness independently on the wind flow a special system basing on the submerged mosquito mesh (cell of 2*2 mm) was used (see [4]). The roughness was controlled by the depth of the mesh installation under the free surface (no waves when the mesh was on the surface and maximum wave amplitude for the maximum depth). So, for each wind speed several cases of the waves parameters were investigated. During experiments a stable stratification of the boundary layer of air flow was obtained. Temperature of the heating air was 33-37 degrees (depending on the reference wind speed), and the water temperature was 14-16 degrees. The Pitote gauge and hotwire were used together for measuring velocity and temperature profiles. Also indirect estimations of the total volume of the phase of sprays were obtained by analyzing hotwire signals errors during droplets hits. Then aerodynamic drag CD and heat transfer Ch coefficients were obtained by profiling method. It was shown that that these parameters are very sensitive to the intensity of

  2. Modified hot-conditioning of PHT system surfaces of PHWRs

    International Nuclear Information System (INIS)

    Venkateswaran, G.

    1997-01-01

    The increased awareness on the importance of controlling activity transport and radiation buildup on out-of-core surfaces of water cooled nuclear reactors is leading to a host of measures both from chemistry as well as engineering sides being undertaken. Passivation of the surfaces of structural materials is one such. Pressurised Heavy Water Reactors of CANDU design use large surface area of carbon steel alloy in the Primary Heat Transport System. Hot-conditioning of the PHT system with deoxygenated light water at temperatures ≅ 473 - 523 K during commissioning stage is done to form a protective magnetite film on the surfaces of carbon steel essentially to guard this material from corrosion during the intervening period between initial commissioning and first fuel loading and achieving nuclear heat. However, a need is felt to improve the quality of this magnetite film and control the crud release so that the twin objectives of controlling the corrosion of carbon steel and reducing a possible deposition of corrosion products on surfaces of fuel clad could be achieved. Laboratory static autoclave investigations have been carried out on the formation of protective magnetite film on carbon steel at 473 K, pH 10 (pH at 298 K) deoxygenated aqueous solutions of chelants like HEDTA, DTPA, NTA apart from EDTA. Additionally, influence of AVT chemicals like hydrazine, cyclohexylamine, morpholine and additives like glucose, boric acid has been studied. The data have been compared with the standard procedure of hot-conditioning namely with simple LiOH. It is found that chelants increase the base metal loss but the oxide formed is more protective than the one formed under simple LiOH treatment. The efficiency of passivation is greatly enhanced by hydrazine and boric acid while it is adversely affected by glucose. AVT chemicals acts as effective corrosion inhibitors. (author). 14 refs, 2 figs, 4 tabs

  3. Evaluation of a bioluminescence method, contact angle measurements and topography for testing the cleanability of plastic surfaces under laboratory conditions

    Science.gov (United States)

    Redsven, I.; Kymäläinen, H.-R.; Pesonen-Leinonen, E.; Kuisma, R.; Ojala-Paloposki, T.; Hautala, M.; Sjöberg, A.-M.

    2007-04-01

    Detection of adenosine triphosphate (ATP) by bioluminescence is used, for instance, in the food industry and in hospitals to assess the hygiene status of surfaces. The aim of this laboratory study was to investigate the feasibility of the ATP method for estimating the cleanability of resilient floor coverings from biological soil. The surfaces were worn using a Soiling and Wearing Drum Tester, and soiled and cleaned with an Erichsen Washability and Scrubbing Resistance Tester. In the laboratory test carried out with the bioluminescence method, most of the new and worn floor coverings that were biologically soiled were cleaned efficiently. According to this study, the semiquantitative ATP screening method can be used for hygiene monitoring of flooring materials. No correlation was found between cleanability and contact angles or surface topography measured using a profilometer. However, by revealing local irregularities and damage on surfaces, scanning electron micrographs appeared useful in explaining differences in cleanability.

  4. TEACHING PHYSICS: Stockholm Science Laboratory for Schools: a complement to the traditional education system

    Science.gov (United States)

    Johansson, K. E.; Nilsson, Ch

    1999-11-01

    The Science Laboratory for Schools is a physics laboratory at the Department of Physics at Stockholm University in Sweden. The laboratory plays an important role in making modern physics accessible to teachers, school classes and individual students. It is a resource for the teachers and their classes, and a complement to the traditional education system.

  5. Surface Energy Balance System (SEBS) Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Cook, D. R. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-01-01

    A Surface Energy Balance System (SEBS) has been installed collocated with each deployed Eddy Correlation Flux Measurement System (ECOR) at the Atmospheric Radiation Measurement (ARM) Climate Research Facility’s Southern Great Plains (SGP) site, North Slope of Alaska (NSA) site, first ARM Mobile Facility (AMF1), second ARM Mobile Facility (AMF2), and third ARM Mobile Facility (AMF3) at Oliktok Point (OLI). A SEBS was also deployed with the Tropical Western Pacific (TWP) site, before it was decommissioned. Data from these sites, including the retired TWP, are available in the ARM Data Archive. The SEBS consists of upwelling and downwelling solar and infrared radiometers within one net radiometer, a wetness sensor, and soil measurements. The SEBS measurements allow the comparison of ECOR sensible and latent heat fluxes with the energy balance determined from the SEBS and provide information on wetting of the sensors for data quality purposes.

  6. Estimating the Analytical and Surface Enhancement Factors in Surface-Enhanced Raman Scattering (SERS): A Novel Physical Chemistry and Nanotechnology Laboratory Experiment

    Science.gov (United States)

    Pavel, Ioana E.; Alnajjar, Khadijeh S.; Monahan, Jennifer L.; Stahler, Adam; Hunter, Nora E.; Weaver, Kent M.; Baker, Joshua D.; Meyerhoefer, Allie J.; Dolson, David A.

    2012-01-01

    A novel laboratory experiment was successfully implemented for undergraduate and graduate students in physical chemistry and nanotechnology. The main goal of the experiment was to rigorously determine the surface-enhanced Raman scattering (SERS)-based sensing capabilities of colloidal silver nanoparticles (AgNPs). These were quantified by…

  7. ELAN - expert system supported information and management system for analytical laboratories. ELAN - Expertengestuetztes Informationssystem fuer die Laboranalytik

    Energy Technology Data Exchange (ETDEWEB)

    Orth, H.; Zilly, G.

    1990-05-01

    The demand for high efficiency and short response time calls for the use of computer support in chemico-analytical laboratories. This is usually achieved by laboratory information and management systems covering the three levels of analytical instrument automation, laboratory operation support and laboratory management. The management component of the systems implemented up to now suffers from a lack of flexibility as far as unforeseen analytical investigations outside the laboratory routine work are concerned. Another drawback is the lack of adaptability with respect to structural changes in laboratory organization. It can be eliminated by the application of expert system structures and methods for the implementation of this system level. The ELAN laboratory information and management system has been developed on the basis of this concept. (orig.).

  8. Virtual Earth System Laboratory (VESL): Effective Visualization of Earth System Data and Process Simulations

    Science.gov (United States)

    Quinn, J. D.; Larour, E. Y.; Cheng, D. L. C.; Halkides, D. J.

    2016-12-01

    The Virtual Earth System Laboratory (VESL) is a Web-based tool, under development at the Jet Propulsion Laboratory and UC Irvine, for the visualization of Earth System data and process simulations. It contains features geared toward a range of applications, spanning research and outreach. It offers an intuitive user interface, in which model inputs are changed using sliders and other interactive components. Current capabilities include simulation of polar ice sheet responses to climate forcing, based on NASA's Ice Sheet System Model (ISSM). We believe that the visualization of data is most effective when tailored to the target audience, and that many of the best practices for modern Web design/development can be applied directly to the visualization of data: use of negative space, color schemes, typography, accessibility standards, tooltips, etc cetera. We present our prototype website, and invite input from potential users, including researchers, educators, and students.

  9. Automation in control laboratory and related information management system

    International Nuclear Information System (INIS)

    Gopalan, B.; Syamsundar, S.

    1997-01-01

    In the field of technology, the word automation is often employed to indicate many types of mechanized operations, though in the strict sense it means those operations which involve application of an element of knowledge or decision making without the intervention of human mind. In laboratory practice for example, the use of multi-sample array turret and millivolt recorder connected to a spectrophotometer represents a situation of mechanized operation as these gadgets help eliminating human muscle power. If a micro processor or a computer is connected to the above equipment for interpreting the measured parameters and establishing calibration graphs or display concentration results, then a real automated situation results where the application of human mind is eliminated. The state of the art of modern laboratory analysis abounds in the employment of automatic analytical equipment thanks to the development in the field of VLSI, computer, software etc. and this has given rise to the concept of laboratory automation

  10. The evolution of the Carpathians-Pannonian system: Interaction between neotectonics, deep structure, polyphase orogeny and sedimentary basins in a source to sink natural laboratory.

    NARCIS (Netherlands)

    Cloetingh, S.A.P.L.; Matenco, L.C.; Bada, G.; Dinu, C.; Mocanu, V.I.

    2005-01-01

    The Carpathians-Pannonian Basin system provides a natural laboratory for analysing lithospheric to surface controls on tectonic topography development in a coupled source-to-sink environment. To link processes taking place at depth and at the surface, recent research focused on the interplay between

  11. Potential for saturated ground-water system contamination at the Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Stone, R.; Ruggieri, M.R.; Rogers, L.L.; Emerson, D.O.; Buddemeier, R.W.

    1982-01-01

    A program of hydrogeologic investigation has been carried out to determine the likelihood of contaminant movement to the saturated zone from near the ground surface at Lawrence Livermore National Laboratory (LLNL). A companion survey of potential contaminant sources was also conducted at the LLNL. Water samples from selected LLNL wells were analyzed to test the water quality in the uppermost part of the saturated zone, which is from 14 to 48 m (45 to 158 ft) beneath the surface. Only nitrate and tritium were found in concentrations above natural background. In one well, the nitrate was slightly more concentrated than the drinking water limit. The nitrate source has not been found. The tritium in all ground-water samples from wells was found far less concentrated than the drinking water limit. The extent of infiltration of surface water was traced with environmental tritium. The thickness and stratigraphy of the unsaturated zone beneath the LLNL, and nearby area, was determined with specially constructed wells and boreholes. Well hydrograph analysis indicated where infiltration of surface water reached the saturated ground-water system. The investigation indicates that water infiltrating from the surface, through alluvial deposits, reaches the saturated zone along the course of Arroyo Seco, Arroyo Las Positas, and from the depression near the center of the site where seasonal water accumulates. Several potential contaminant sources were identified, and it is likely that contaminants could move from near the ground surface to the saturated zone beneath LLNL. Additional ground-water sampling and analysis will be performed and ongoing investigations will provide estimates of the speed with which potential contaminants can flow laterally in the saturated zone beneath LLNL. 34 references, 61 figures, 16 tables

  12. Laboratorial training of examiners for using a visual caries detection system in epidemiological surveys.

    Science.gov (United States)

    Piovesan, Chaiana; Moro, Bruna Lp; Lara, Juan S; Ardenghi, Thiago M; Guedes, Renata S; Haddad, Ana E; Braga, Mariana M; Mendes, Fausto M

    2013-10-03

    In epidemiological surveys, a good reliability among the examiners regarding the caries detection method is essential. However, training and calibrating those examiners is an arduous task because it involves several patients who are examined many times. To facilitate this step, we aimed to propose a laboratory methodology to simulate the examinations performed to detect caries lesions using the International Caries Detection and Assessment System (ICDAS) in epidemiological surveys. A benchmark examiner conducted all training sessions. A total of 67 exfoliated primary teeth, varying from sound to extensive cavitated, were set in seven arch models to simulate complete mouths in primary dentition. Sixteen examiners (graduate students) evaluated all surfaces of the teeth under illumination using buccal mirrors and ball-ended probe in two occasions, using only coronal primary caries scores of the ICDAS. As reference standard, two different examiners assessed the proximal surfaces by direct visual inspection, classifying them in sound, with non-cavitated or with cavitated lesions. After, teeth were sectioned in the bucco-lingual direction, and the examiners assessed the sections in stereomicroscope, classifying the occlusal and smooth surfaces according to lesion depth. Inter-examiner reproducibility was evaluated using weighted kappa. Sensitivities and specificities were calculated at two thresholds: all lesions and advanced lesions (cavitated lesions in proximal surfaces and lesions reaching the dentine in occlusal and smooth surfaces). Regarding the reproducibility, the mean (range) of kappa values was 0.781 (0.529-0.927) for occlusal surfaces, 0.568 (0.191-0.881) for smooth surfaces, and 0.844 (0.698-0.971) for proximal surfaces. Considering all lesions, sensitivity and specificity mean values were respectively 0.724 and 0.844 for occlusal, 0.635 and 0.943 for smooth and 0.658 and 0.927 for proximal surfaces. For detecting advanced lesions, sensitivities and

  13. Common Learning Objectives for Undergraduate Control Systems Laboratories

    Science.gov (United States)

    Reck, Rebecca M.

    2017-01-01

    Course objectives, like research objectives and product requirements, help provide clarity and direction for faculty and students. Unfortunately, course and laboratory objectives are not always clearly stated. Without a clear set of objectives, it can be hard to design a learning experience and determine whether students are achieving the intended…

  14. ARM Surface Meteorology Systems Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Ritsche, MT

    2011-03-08

    The ARM Surface Meteorology Systems consist mainly of conventional in situ sensors that obtain a defined “core” set of measurements. The core set of measurements is: Barometric Pressure (kPa), Temperature (°C), Relative Humidity (%), Arithmetic-Averaged Wind Speed (m/s), Vector-Averaged Wind Speed (m/s), and Vector-Averaged Wind Direction (deg). The sensors that collect the core variables are mounted at the standard heights defined for each variable: • Winds: 10 meters • Temperature and Relative Humidity: 2 meters • Barometric Pressure: 1 meter. Depending upon the geographical location, different models and types of sensors may be used to measure the core variables due to the conditions experienced at those locations. Most sites have additional sensors that measure other variables that are unique to that site or are well suited for the climate of the location but not at others.

  15. Surface Management System Departure Event Data Analysis

    Science.gov (United States)

    Monroe, Gilena A.

    2010-01-01

    This paper presents a data analysis of the Surface Management System (SMS) performance of departure events, including push-back and runway departure events.The paper focuses on the detection performance, or the ability to detect departure events, as well as the prediction performance of SMS. The results detail a modest overall detection performance of push-back events and a significantly high overall detection performance of runway departure events. The overall detection performance of SMS for push-back events is approximately 55%.The overall detection performance of SMS for runway departure events nears 100%. This paper also presents the overall SMS prediction performance for runway departure events as well as the timeliness of the Aircraft Situation Display for Industry data source for SMS predictions.

  16. Implementing an integrated standards-based management system to ensure compliance at Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    Hjeresen, D.; Roybal, S.; Bertino, P.; Gherman, C.; Hosteny, B.

    1995-01-01

    Los Alamos National Laboratory (LANL or the Laboratory) is developing and implementing a comprehensive, Integrated Standards-Based Management System (ISBMS) to enhance environmental, safety, and health (ESH) compliance efforts and streamline management of ESH throughout the Laboratory. The Laboratory recognizes that to be competitive in today's business environment and attractive to potential Partnerships, Laboratory operations must be efficient and cost-effective. The Laboratory also realizes potential growth opportunities for developing ESH as a strength in providing new or improved services to its customers. Overall, the Laboratory desires to establish and build upon an ESH management system which ensures continuous improvement in protecting public health and safety and the environment and which fosters a working relationship with stakeholders. A team of process experts from the LANL Environmental Management (EM) Program Office, worked with management system consultants, and the Department of Energy (DOE) to develop an ESH management systems process to compare current LANL ESH management Systems and programs against leading industry standards. The process enabled the Laboratory to gauge its performance in each of the following areas: Planning and Policy Setting; Systems and Procedures; Implementation and Education; and Monitoring and Reporting. The information gathered on ESH management systems enabled LANL to pinpoint and prioritize opportunities for improvement in the provision of ESH services throughout the Laboratory and ultimately overall ESH compliance

  17. Laboratory simulations of planetary surfaces: Understanding regolith physical properties from remote photopolarimetric observations

    Science.gov (United States)

    Nelson, Robert M.; Boryta, Mark D.; Hapke, Bruce W.; Manatt, Kenneth S.; Shkuratov, Yuriy; Psarev, V.; Vandervoort, Kurt; Kroner, Desire; Nebedum, Adaze; Vides, Christina L.; Quiñones, John

    2018-03-01

    We present reflectance and polarization phase curve measurements of highly reflective planetary regolith analogues having physical characteristics expected on atmosphereless solar system bodies (ASSBs) such as a eucritic asteroids or icy satellites. We used a goniometric photopolarimeter (GPP) of novel design to study thirteen well-sorted particle size fractions of aluminum oxide (Al2O3). The sample suite included particle sizes larger than, approximately equal to, and smaller than the wavelength of the incident monochromatic radiation (λ = 635 nm). The observed phase angle, α, was 0.056 o ∼95%). The incident radiation has a very high probability of being multiply scattered before being backscattered toward the incident direction or ultimately absorbed. The five smallest particle sizes exhibited extremely high void space (> ∼95%). The reflectance phase curves for all particle size fractions show a pronounced non-linear reflectance increase with decreasing phase angle at α∼ ∼1 we detect no polarization. This polarization behavior is distinct from that observed in low albedo solar system objects such as the Moon and asteroids and for absorbing materials in the laboratory. We suggest this behavior arises because photons that are backscattered have a high probability of having interacted with two or more particles, thus giving rise to the CB process. These results may explain the unusual negative polarization behavior observed near small phase angles reported for several decades on highly reflective ASSBs such as the asteroids 44 Nysa, 64 Angelina and the Galilean satellites Io, Europa and Ganymede. Our results suggest these ASSB regoliths scatter electromagnetic radiation as if they were extremely fine grained with void space > ∼95%, and grain sizes of the order field of terrestrial geo-engineering, particularly to suggestions that earth's radiation balance can be modified by injecting Al2O3 particulates into the stratosphere thereby offsetting the effect

  18. A mobile laboratory for surface and subsurface imaging in geo-hazard monitoring activity

    Science.gov (United States)

    Cornacchia, Carmela; Bavusi, Massimo; Loperte, Antonio; Pergola, Nicola; Pignatti, Stefano; Ponzo, Felice; Lapenna, Vincenzo

    2010-05-01

    A new research infrastructure for supporting ground-based remote sensing observations in the different phases of georisk management cycle is presented. This instrumental facility has been designed and realised by TeRN, a public-private consortium on Earth Observations and Natural Risks, in the frame of the project "ImpresAmbiente" funded by Italian Ministry of Research and University. The new infrastructure is equipped with ground-based sensors (hyperspectral cameras, thermal cameras, laser scanning and electromagnetic antennae) able to remotely map physical parameters and/or earth-surface properties (temperature, soil moisture, land cover, etc…) and to illuminate near-surface geological structures (fault, groundwater tables, landslide bodies etc...). Furthermore, the system can be used for non-invasive investigations of architectonic buildings and civil infrastructures (bridges, tunnel, road pavements, etc...) interested by natural and man-made hazards. The hyperspectral cameras can acquire high resolution images of earth-surface and cultural objects. They are operating in the Visible Near InfraRed (0.4÷1.0μm) with 1600 spatial pixel and 3.7nm of spectral sampling and in the Short Wave InfraRed (1.3÷2.5µm) spectral region with 320 spatial pixel and 5nm of spectral sampling. The IR cameras are operating in the Medium Wavelength InfraRed (3÷5µm; 640x512; NETDfield, as geology, architecture, environmental monitoring and cultural heritage. As a consequence, laser data can be useful integrated with traditional monitoring techniques. The Laser Scanner is characterized by very high data acquisition repetition rate up to 500.000 pxl/sec with a range resolution of 0.1 mm, vertical and horizontal FoV of 310° and 360° respectively with a resolution of 0.0018°. The system is also equipped with a metric camera allows to georeference the high resolution images acquired. The electromagnetic sensors allow to obtain in near real time high-resolution 2D and 3D subsurface

  19. Global health: Integrating national laboratory health systems and services in resource-limited settings

    Directory of Open Access Journals (Sweden)

    Linda M. Parsons

    2012-06-01

    Full Text Available Laboratory systems worldwide are challenged not only by the need to compete for scarce resources with other sections of national health care programmes, but also with the lack of understanding of the critical role that laboratories play in the accurate diagnosis and monitoring of patients suffering from high-burdens of disease. An effective approach to establishing cost-effective laboratory systems that provide rapid and accurate test results for optimal impact on patient care is to move away from disease-specific programmes and establish integrated laboratory services. An integrated laboratory network provides all primary diagnostic services needed for care and treatment without requiring patients to go to different laboratory facilities for specific tests. Such a network focuses on providing quality-assured basic laboratory testing through the use of common specimen collection, reporting and diagnostic platforms that can be used across diseases. An integrated laboratory system also provides specimen transport to specialised laboratories and an environment conducive to the introduction and use of new and more complex technologies that would benefit the patient population and public health systems as a whole. As such, this article described various strategies for, and practical examples of, the successful integration of laboratory services.

  20. Global health: Integrating national laboratory health systems and services in resource-limited settings.

    Science.gov (United States)

    Parsons, Linda M; Somoskovi, Akos; Lee, Evan; Paramasivan, Chinnambedu N; Schneidman, Miriam; Birx, Deborah; Roscigno, Giorgio; Nkengasong, John

    2012-01-01

    Laboratory systems worldwide are challenged not only by the need to compete for scarce resources with other sections of national health care programmes, but also with the lack of understanding of the critical role that laboratories play in the accurate diagnosis and monitoring of patients suffering from high-burdens of disease. An effective approach to establishing cost-effective laboratory systems that provide rapid and accurate test results for optimal impact on patient care is to move away from disease-specific programmes and establish integrated laboratory services. An integrated laboratory network provides all primary diagnostic services needed for care and treatment without requiring patients to go to different laboratory facilities for specific tests. Such a network focuses on providing quality-assured basic laboratory testing through the use of common specimen collection, reporting and diagnostic platforms that can be used across diseases. An integrated laboratory system also provides specimen transport to specialised laboratories and an environment conducive to the introduction and use of new and more complex technologies that would benefit the patient population and public health systems as a whole. As such, this article described various strategies for, and practical examples of, the successful integration of laboratory services.

  1. Laboratory coupling tests for optimum land streamer design over sand dunes surface

    KAUST Repository

    Almalki, Hashim

    2012-02-26

    The cost of data acquisition in land is becoming a major issue as we strive to cover larger areas with seismic surveys at high resolution. Over sand dunes the problem is compounded by the week coupling obtain using geophones, which often forces us to bury the phone. A major challenge is designing such a land streamer system that combines durability, mobility and the required coupling. We share a couple of such designs and discuss the merits behind such designs and test their capability. The testing includes, the level of coupling, mobility and drag over sand surfaces. For specific designs loose sand can accumulate inside the steamer reducing its mobility. On the other hand, poor coupling will attenuate the high frequencies and cause an effective delay in the signal. The weight of the streamer is also an important factor in both mobility and coupling as it adds to the coupling it reduces the mobility of the streamer. We study the impact of weight and base plate surface area on the seismic signal quality, as well as the friction factor of different designs.

  2. A Project-Based Laboratory for Learning Embedded System Design with Industry Support

    Science.gov (United States)

    Lee, Chyi-Shyong; Su, Juing-Huei; Lin, Kuo-En; Chang, Jia-Hao; Lin, Gu-Hong

    2010-01-01

    A project-based laboratory for learning embedded system design with support from industry is presented in this paper. The aim of this laboratory is to motivate students to learn the building blocks of embedded systems and practical control algorithms by constructing a line-following robot using the quadratic interpolation technique to predict the…

  3. GESCAL: Quality management automated system for a calibration and test laboratory

    International Nuclear Information System (INIS)

    Manzano de Armas, J.; Valdes Ramos, M.; Morales Monzon, J.A.

    1998-01-01

    GESCAL is a software created to automate all elements composing the quality system in a calibration and test laboratory. It also evaluates quality according to its objectives and policies. This integrated data system decreases considerably the amount of time devoted to manage quality. It is speedier in searching and evaluating information registers thus notably in reducing the workload for laboratory staff

  4. Culturing Security System of Chemical Laboratory in Indonesia

    OpenAIRE

    Pusfitasari, Eka Dian

    2017-01-01

    Indonesia has experiences on the lack of chemical security such as: a number of bombing terrors and hazardous chemicals found in food. Bomb used in terror is a homemade bomb made from chemicals which are widely spread in the research laboratories such as a mixture of pottasium chlorate, sulphur, and alumunium. Therefore, security of chemicals should be implemented to avoid the misused of the chemicals. Although it has experienced many cases of the misuse of chemicals, and many regulations and...

  5. Mg Isotope Inter-Laboratory Comparison of Reference Materials from Earth-Surface Low-Temperature Environments

    OpenAIRE

    Shalev, Netta; Farkas, Juraj; Fietzke, Jan; Novak, Martin; Schuessler, Jan A.; Pogge von Strandmann, Philip A.E; Törber, Philip B.

    2018-01-01

    To enable quality control of measurement procedures for determinations of Mg isotope amount ratios, expressed as δ26Mg and δ25Mg values, in Earth-surface studies, the δ26Mg and δ25Mg values of eight reference materials (RMs) were determined by inter-laboratory comparison between five laboratories and considering published data, if available. These matrix RMs, including river water SLRS-5, spring water NIST SRM 1640a, Dead Sea brine DSW-1, dolomites JDo-1 and CRM 512, limestone CRM 513, soil N...

  6. Employee Engagement Is Vital for the Successful Selection of a Total Laboratory Automation System.

    Science.gov (United States)

    Yu, Hoi-Ying E; Wilkerson, Myra L

    2017-11-08

    To concretely outline a process for selecting a total laboratory automation system that connects clinical chemistry, hematology, and coagulation analyzers and to serve as a reference for other laboratories. In Phase I, a committee including the laboratory's directors and technologists conducted a review of 5 systems based on formal request for information process, site visits, and vendor presentations. We developed evaluation criteria and selected the 2 highest performing systems. In Phase II, we executed a detailed comparison of the 2 vendors based on cost, instrument layout, workflow design, and future potential. In addition to selecting a laboratory automation system, we used the process to ensure employee engagement in preparation for implementation. Selecting a total laboratory automation system is a complicated process. This paper provides practical guide in how a thorough selection process can be done with participation of key stakeholders. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  7. Identification of laboratory techniques to optimize Superpave HMA surface friction characteristics : final report, April 2010.

    Science.gov (United States)

    2010-04-15

    Wet pavement friction is known to be one of the most important roadway safety parameters. In this : research, frictional properties of flexible (asphalt) pavements were investigated. : As a part of this study, a laboratory device to polish asphalt sp...

  8. Thermal performance of marketed SDHW systems under laboratory conditions

    DEFF Research Database (Denmark)

    Furbo, Simon; Andersen, Elsa; Fan, Jianhua

    A test facility for solar domestic hot water systems, SDHW systems was established at the Technical University of Denmark in 1992. During the period 1992-2012 21 marketed SDHW systems, 16 systems from Danish manufacturers and 5 systems from manufacturers from abroad, have been tested in the test...... comfort, avoiding simple errors, using the low flow principle and heat stores with a high degree of thermal stratification and by using components with good thermal characteristics....

  9. Surface Contamination Monitor and Survey Information Management System

    International Nuclear Information System (INIS)

    1998-02-01

    Shonka Research Associates, Inc.'s (SRA) Surface Contamination Monitor and Survey Information management System (SCM/SIMS) is designed to perform alpha and beta radiation surveys of floors and surfaces and document the measured data. The SRA-SCM/SIMS technology can be applied to routine operational surveys, characterization surveys, and free release and site closure surveys. Any large nuclear site can make use of this technology. This report describes a demonstration of the SRA-SCM/SIMS technology. This demonstration is part of the chicago Pile-5 (CP-5) Large-Scale Demonstration Project (LSDP) sponsored by the US Department of Energy (DOE), Office of Science and Technology (ST), Deactivation and Decommissioning Focus Area (DDFA). The objective of the LSDP is to select and demonstrate potentially beneficial technologies at the Argonne National Laboratory-East's (ANL) CP-5 Research Reactor Facility. The purpose of the LSDP is to demonstrate that by using innovative and improved deactivation and decommissioning (D and D) technologies from various sources, significant benefits can be achieved when compared to baseline D and D technologies

  10. Surface Contamination Monitor and Survey Information Management System

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-02-01

    Shonka Research Associates, Inc.`s (SRA) Surface Contamination Monitor and Survey Information management System (SCM/SIMS) is designed to perform alpha and beta radiation surveys of floors and surfaces and document the measured data. The SRA-SCM/SIMS technology can be applied to routine operational surveys, characterization surveys, and free release and site closure surveys. Any large nuclear site can make use of this technology. This report describes a demonstration of the SRA-SCM/SIMS technology. This demonstration is part of the chicago Pile-5 (CP-5) Large-Scale Demonstration Project (LSDP) sponsored by the US Department of Energy (DOE), Office of Science and Technology (ST), Deactivation and Decommissioning Focus Area (DDFA). The objective of the LSDP is to select and demonstrate potentially beneficial technologies at the Argonne National Laboratory-East`s (ANL) CP-5 Research Reactor Facility. The purpose of the LSDP is to demonstrate that by using innovative and improved deactivation and decommissioning (D and D) technologies from various sources, significant benefits can be achieved when compared to baseline D and D technologies.

  11. Precision Subsampling System for Mars Surface Missions

    Science.gov (United States)

    Mahaffy, P. R.; Paulsen, G.; Mellerowicz, B.; ten Kate, I. L.; Conrad, P.; Corrigan, C. M.; Li, X.

    2012-01-01

    The ability to analyze heterogeneous rock samples at fine spatial scales would represent a powerful addition to our planetary in situ analytical toolbox. This is particularly true for Mars, where the signatures of past environments and, potentially, habitability are preserved in chemical and morphological variations across sedimentary layers and among mineral pr.ases in a given rock specimen. On Earth, microbial life often associates with surfaces at the interface of chemical nutrients, and ultimately retains sub-millimeter to millimeter-scale layer confinement in fossilization. On Mars, and possibly other bodies, trace chemical markers (elemental, organic/molecular, isotopic, chiral, etc.) and fine-scale morphological markers (e.g., micro-fossils) may he too subtle, degraded, or ambiguous to be detected, using miniaturized instrumentation, without some concentration or isolation. This is because (i) instrument sensitivity may not be high enough to detect trace markers in bulk averages; and (ii) instrument slectiviry may not be sufficient to distinguish such markers from interfering/counteracting signals from the bulk. Moreover from a fundamental chemostratigraphic perspective there would be a great benefit to assessing specific chemical and stable isotopic gradients, over millimeter-to-centimeter scales and beyond, with higher precision than currently possible in situ. We have developed a precision subsampling system (PSS) that addresses this need while remaining relatively flexible to a variety of instruments that may take advantage of the capability on future missions. The PSS is relevant to a number of possible lander/rover missions, especially Mars Sample Return. Our specific PSS prototype is undergoing testing under Mars ambient conditions, on a variety of natural analog rocks and rock drill cores, using a set of complementary flight-compatible measurement techniques. The system is available for testing with other contact instruments that may benefit from

  12. RASSOR - Regolith Advanced Surface Systems Operations Robot

    Science.gov (United States)

    Gill, Tracy R.; Mueller, Rob

    2015-01-01

    The Regolith Advanced Surface Systems Operations Robot (RASSOR) is a lightweight excavator for mining in reduced gravity. RASSOR addresses the need for a lightweight (robot that is able to overcome excavation reaction forces while operating in reduced gravity environments such as the moon or Mars. A nominal mission would send RASSOR to the moon to operate for five years delivering regolith feedstock to a separate chemical plant, which extracts oxygen from the regolith using H2 reduction methods. RASSOR would make 35 trips of 20 kg loads every 24 hours. With four RASSORs operating at one time, the mission would achieve 10 tonnes of oxygen per year (8 t for rocket propellant and 2 t for life support). Accessing craters in space environments may be extremely hard and harsh due to volatile resources - survival is challenging. New technologies and methods are required. RASSOR is a product of KSC Swamp Works which establishes rapid, innovative and cost effective exploration mission solutions by leveraging partnerships across NASA, industry and academia.

  13. Lunar Surface Systems Supportability Technology Development Roadmap

    Science.gov (United States)

    Oeftering, Richard C.; Struk, Peter M.; Green, Jennifer L.; Chau, Savio N.; Curell, Philip C.; Dempsey, Cathy A.; Patterson, Linda P.; Robbins, William; Steele, Michael A.; DAnnunzio, Anthony; hide

    2011-01-01

    The Lunar Surface Systems Supportability Technology Development Roadmap is a guide for developing the technologies needed to enable the supportable, sustainable, and affordable exploration of the Moon and other destinations beyond Earth. Supportability is defined in terms of space maintenance, repair, and related logistics. This report considers the supportability lessons learned from NASA and the Department of Defense. Lunar Outpost supportability needs are summarized, and a supportability technology strategy is established to make the transition from high logistics dependence to logistics independence. This strategy will enable flight crews to act effectively to respond to problems and exploit opportunities in an environment of extreme resource scarcity and isolation. The supportability roadmap defines the general technology selection criteria. Technologies are organized into three categories: diagnostics, test, and verification; maintenance and repair; and scavenge and recycle. Furthermore, "embedded technologies" and "process technologies" are used to designate distinct technology types with different development cycles. The roadmap examines the current technology readiness level and lays out a four-phase incremental development schedule with selection decision gates. The supportability technology roadmap is intended to develop technologies with the widest possible capability and utility while minimizing the impact on crew time and training and remaining within the time and cost constraints of the program.

  14. Expert Assessment of Conditions for Accredited Quality Management System Functioning in Testing Laboratories

    Science.gov (United States)

    Mytych, Joanna; Ligarski, Mariusz J.

    2018-03-01

    The quality management systems compliant with the ISO 9001:2009 have been thoroughly researched and described in detail in the world literature. The accredited management systems used in the testing laboratories and compliant with the ISO/IEC 17025:2005 have been mainly described in terms of the system design and implementation. They have also been investigated from the analytical point of view. Unfortunately, a low number of studies concerned the management system functioning in the accredited testing laboratories. The aim of following study was to assess the management system functioning in the accredited testing laboratories in Poland. On 8 October 2015, 1,213 accredited testing laboratories were present in Poland. They investigated various scientific areas and substances/objects. There are more and more such laboratories that have various problems and different long-term experience when it comes to the implementation, maintenance and improvement of the management systems. The article describes the results of the conducted expert assessment (survey) carried out to examine the conditions for the functioning of a management system in an accredited laboratory. It also focuses on the characteristics of the accredited research laboratories in Poland. The authors discuss the selection of the external and internal conditions that may affect the accredited management system. They show how the experts assessing the selected conditions were chosen. The survey results are also presented.

  15. Geometric Description of Fibre Bundle Surface for Birkhoff System

    International Nuclear Information System (INIS)

    Li-Mei, Cao; Hua-Fei, Sun; Zhen-Ning, Zhang

    2009-01-01

    A fibre bundle surface for the Birkhoff system is constructed. The metric and the Riemannian connection of the surface are defined and the representation of the Gaussian curvature of this surface is presented. Finally, three examples for the Birkhoff system are given to illustrate our results. (general)

  16. Developing a customised approach for strengthening tuberculosis laboratory quality management systems toward accreditation

    Directory of Open Access Journals (Sweden)

    Heidi Albert

    2017-03-01

    Full Text Available Background: Quality-assured tuberculosis laboratory services are critical to achieve global and national goals for tuberculosis prevention and care. Implementation of a quality management system (QMS in laboratories leads to improved quality of diagnostic tests and better patient care. The Strengthening Laboratory Management Toward Accreditation (SLMTA programme has led to measurable improvements in the QMS of clinical laboratories. However, progress in tuberculosis laboratories has been slower, which may be attributed to the need for a structured tuberculosis-specific approach to implementing QMS. We describe the development and early implementation of the Strengthening Tuberculosis Laboratory Management Toward Accreditation (TB SLMTA programme. Development: The TB SLMTA curriculum was developed by customizing the SLMTA curriculum to include specific tools, job aids and supplementary materials specific to the tuberculosis laboratory. The TB SLMTA Harmonized Checklist was developed from the World Health Organisation Regional Office for Africa Stepwise Laboratory Quality Improvement Process Towards Accreditation checklist, and incorporated tuberculosis-specific requirements from the Global Laboratory Initiative Stepwise Process Towards Tuberculosis Laboratory Accreditation online tool. Implementation: Four regional training-of-trainers workshops have been conducted since 2013. The TB SLMTA programme has been rolled out in 37 tuberculosis laboratories in 10 countries using the Workshop approach in 32 laboratories in five countries and the Facility based approach in five tuberculosis laboratories in five countries. Conclusion: Lessons learnt from early implementation of TB SLMTA suggest that a structured training and mentoring programme can build a foundation towards further quality improvement in tuberculosis laboratories. Structured mentoring, and institutionalisation of QMS into country programmes, is needed to support tuberculosis laboratories

  17. The Integrated Cloud-based Environmental Data Management System at Los Alamos National Laboratory - 13391

    International Nuclear Information System (INIS)

    Schultz Paige, Karen; Gomez, Penny; Patel, Nita P.; EchoHawk, Chris; Dorries, Alison M.

    2013-01-01

    In today's world, instant access to information is taken for granted. The national labs are no exception; our data users expect immediate access to their data. Los Alamos National Laboratory (LANL) has collected over ten million records, and the data needs to be accessible to scientists as well as the public. The data span a wide range of media, analytes, time periods, formats, and quality and have traditionally existed in scattered databases, making comprehensive work with the data impossible. Recently, LANL has successfully integrated all their environmental data into a single, cloud-based, web-accessible data management system. The system combines data transparency to the public with immediate access required by the technical staff. The use of automatic electronic data validation has been critical to immediate data access while saving millions of dollars and increasing data consistency and quality. The system includes a Google Maps based GIS tool that is simple enough for people to locate potentially contaminated sites near their home or workplace, and complex enough to allow scientists to plot and trend their data at the surface and at depth as well as over time. A variety of formatted reports can be run at any desired frequency to report the most current data available in the data base. The advanced user can also run free form queries of the data base. This data management system has saved LANL time and money, an increasingly important accomplishment during periods of budget cuts with increasing demand for immediate electronic services. (authors)

  18. The Integrated Cloud-based Environmental Data Management System at Los Alamos National Laboratory - 13391

    Energy Technology Data Exchange (ETDEWEB)

    Schultz Paige, Karen; Gomez, Penny; Patel, Nita P.; EchoHawk, Chris; Dorries, Alison M. [Los Alamos National Laboratory, MS M996, Los Alamos, NM, 87544 (United States)

    2013-07-01

    In today's world, instant access to information is taken for granted. The national labs are no exception; our data users expect immediate access to their data. Los Alamos National Laboratory (LANL) has collected over ten million records, and the data needs to be accessible to scientists as well as the public. The data span a wide range of media, analytes, time periods, formats, and quality and have traditionally existed in scattered databases, making comprehensive work with the data impossible. Recently, LANL has successfully integrated all their environmental data into a single, cloud-based, web-accessible data management system. The system combines data transparency to the public with immediate access required by the technical staff. The use of automatic electronic data validation has been critical to immediate data access while saving millions of dollars and increasing data consistency and quality. The system includes a Google Maps based GIS tool that is simple enough for people to locate potentially contaminated sites near their home or workplace, and complex enough to allow scientists to plot and trend their data at the surface and at depth as well as over time. A variety of formatted reports can be run at any desired frequency to report the most current data available in the data base. The advanced user can also run free form queries of the data base. This data management system has saved LANL time and money, an increasingly important accomplishment during periods of budget cuts with increasing demand for immediate electronic services. (authors)

  19. Mound Laboratory's Air Surveillance System

    Energy Technology Data Exchange (ETDEWEB)

    Carfagno, D. G.

    1974-12-31

    A comprehensive air surveillance system was developed. The system includes surveillance of the source, transport conditions, and concentration at the receptor sites. An unusual aspect of the system is the implementation of off-site sampling programs through local governmental agencies. Background levels of radioactivity are routinely determined.

  20. The impact of SLMTA in improving laboratory quality systems in the Caribbean Region

    Directory of Open Access Journals (Sweden)

    Giselle Guevara

    2014-11-01

    Objective: To describe the impact of the Strengthening of Laboratory Management Toward Accreditation (SLMTA training programme and mentorship amongst five clinical laboratories in the Caribbean after 18 months. Method: Five national reference laboratories from four countries participated in the SLMTA programme that incorporated classroom teaching and implementation of improvement projects. Mentors were assigned to the laboratories to guide trainees on their improvement projects and to assist in the development of Quality Management Systems (QMS. Audits were conducted at baseline, six months, exit (at 12 months and post-SLMTA (at 18 months using the Stepwise Laboratory Quality Improvement Process Towards Accreditation (SLIPTA checklist to measure changes in implementation of the QMS during the period. At the end of each audit, a comprehensive implementation plan was developed in order to address gaps. Results: Baseline audit scores ranged from 19% to 52%, corresponding to 0 stars on the SLIPTA five-star scale. After 18 months, one laboratory reached four stars, two reached three stars and two reached two stars. There was a corresponding decrease in nonconformities and development of over 100 management and technical standard operating procedures in each of the five laboratories. Conclusion: The tremendous improvement in these five Caribbean laboratories shows that SLMTA coupled with mentorship is an effective, user-friendly, flexible and customisable approach to the implementation of laboratory QMS. It is recommended that other laboratories in the region consider using the SLMTA training programme as they engage in quality systems improvement and preparation for accreditation.

  1. Strengthening Laboratory Capacity for Early Warning Alert and Response System (EWARS) in Indonesia

    OpenAIRE

    Kandel, Nirmal; Hapsari, Ratna Budi; Riana, Dyah Armi; Setiawaty, Vivi; Larasati, Wita; Wulandari, Endang; Purwanto, Edy

    2017-01-01

    Background: Establishment of Early Warning Alert and Response System (EWARS) in Indonesia was initiated since 2009 in few selected provinces and government was planning to roll out in other provinces. Before initiating this roll out the assessment of performance of EWARS in 2012 was conducted. The aim of the assessment is to strengthen laboratory for supporting to EWARS for alerts testing. Methods: Laboratory capacity mapping tool and laboratory algorithm for twenty two priority diseases of ...

  2. Developing an Affordable and Portable Control Systems Laboratory Kit with a Raspberry Pi

    OpenAIRE

    Rebecca M. Reck; R. S. Sreenivas

    2016-01-01

    Instructional laboratories are common in engineering programs. Instructional laboratories should evolve with technology and support the changes in higher education, like the increased popularity of online courses. In this study, an affordable and portable laboratory kit was designed to replace the expensive on-campus equipment for two control systems courses. The complete kit costs under $135 and weighs under 0.68 kilograms. It is comprised of off-the-shelf components (e.g., Raspberry Pi, DC ...

  3. Development of a novel SCADA system for laboratory testing.

    Science.gov (United States)

    Patel, M; Cole, G R; Pryor, T L; Wilmot, N A

    2004-07-01

    This document summarizes the supervisory control and data acquisition (SCADA) system that allows communication with, and controlling the output of, various I/O devices in the renewable energy systems and components test facility RESLab. This SCADA system differs from traditional SCADA systems in that it supports a continuously changing operating environment depending on the test to be performed. The SCADA System is based on the concept of having one Master I/O Server and multiple client computer systems. This paper describes the main features and advantages of this dynamic SCADA system, the connections of various field devices to the master I/O server, the device servers, and numerous software features used in the system. The system is based on the graphical programming language "LabVIEW" and its "Datalogging and Supervisory Control" (DSC) module. The DSC module supports a real-time database called the "tag engine," which performs the I/O operations with all field devices attached to the master I/O server and communications with the other tag engines running on the client computers connected via a local area network. Generic and detailed communication block diagrams illustrating the hierarchical structure of this SCADA system are presented. The flow diagram outlining a complete test performed using this system in one of its standard configurations is described.

  4. STANSORT - Stanford Remote Sensing Laboratory pattern recognition and classification system

    Science.gov (United States)

    Honey, F. R.; Prelat, A.; Lyon, R. J. P.

    1974-01-01

    The principal barrier to routine use of the ERTS multispectral scanner computer compatible tapes, rather than photointerpretation examination of the images, has been the high computing costs involved due to the large quantity of information (4 Mbytes) contained in a scene. STANSORT, the interactive program package developed at Stanford Remote Sensing Laboratories alleviates this problem, providing an extremely rapid, flexible and low cost tool for data reduction, scene classification, species searches and edge detection. The primary classification procedure, utilizing a search with variable gate widths, for similarities in the normalized, digitized spectra is described along with associated procedures for data refinement and extraction of information. The more rigorous statistical classification procedures are also explained.

  5. Laboratory and field scale demonstration of reactive barrier systems

    International Nuclear Information System (INIS)

    Dwyer, B.P.; Marozas, D.C.; Cantrell, K.; Stewart, W.

    1996-10-01

    In an effort to devise a cost efficient technology for remediation of uranium contaminated groundwater, the Department of Energy's Uranium Mill Tailings Remedial Action (DOE-UMTRA) Program through Sandia National Laboratories (SNL) fabricated a pilot scale research project utilizing reactive subsurface barriers at an UMTRA site in Durango, Colorado. A reactive subsurface barrier is produced by placing a reactant material (in this experiment, metallic iron) in the flow path of the contaminated groundwater. The reactive media then removes and/or transforms the contaminant(s) to regulatory acceptable levels. Experimental design and results are discussed with regard to other potential applications of reactive barrier remediation strategies at other sites with contaminated groundwater problems

  6. Computerized nuclear material system at Sandia National Laboratories

    International Nuclear Information System (INIS)

    Tischhauser, J.L.

    1980-01-01

    SNLA developed and implemented a nuclear material control and accountability system on an HP 3000 minicomputer. The Sandia Nuclear Materials Computer System (SNMCS) which became operative in January 1980 provides: control of shipments and receivals of nuclear material, control of internal transfers of nuclear material, automated inventory with a bar code system, control of inventory adjustments, automated reporting/transmitting to other contractors and operations offices, automated ledgers and journals for material weights and costs, and interface to the Albuquerque Operations Office (ALO) Automated 741 System

  7. Application node system image manager subsystem within a distributed function laboratory computer system

    International Nuclear Information System (INIS)

    Stubblefield, F.W.; Beck, R.D.

    1978-10-01

    A computer system to control and acquire data from one x-ray diffraction, five neutron scattering, and four neutron diffraction experiments located at the Brookhaven National Laboratory High Flux Beam Reactor has operated in a routine manner for over three years. The computer system is configured as a network of computer processors with the processor interconnections assuming a star-like structure. At the points of the star are the ten experiment control-data acquisition computers, referred to as application nodes. At the center of the star is a shared service node which supplies a set of shared services utilized by all of the application nodes. A program development node occupies one additional point of the star. The design and implementation of a network subsystem to support development and execution of operating systems for the application nodes is described. 6 figures, 1 table

  8. Hairy Root as a Model System for Undergraduate Laboratory Curriculum and Research

    Science.gov (United States)

    Keyes, Carol A.; Subramanian, Senthil; Yu, Oliver

    2009-01-01

    Hairy root transformation has been widely adapted in plant laboratories to rapidly generate transgenic roots for biochemical and molecular analysis. We present hairy root transformations as a versatile and adaptable model system for a wide variety of undergraduate laboratory courses and research. This technique is easy, efficient, and fast making…

  9. Mixed Methods Student Evaluation of an Online Systemic Human Anatomy Course with Laboratory

    Science.gov (United States)

    Attardi, Stefanie M.; Choi, Suwhan; Barnett, John; Rogers, Kem A.

    2016-01-01

    A fully online section of an existing face-to-face (F2F) systemic human anatomy course with a prosection laboratory was offered for the first time in 2012-2013. Lectures for F2F students (N = 365) were broadcast in both live and archived format to online students (N = 40) using virtual classroom software. Laboratories were delivered online by a…

  10. A Methodology to Obtain Learning Effective Laboratories with Learning Management System Integration

    Science.gov (United States)

    Ruano, Ildefonso; Gamez, Javier; Dormido, Sebastian; Gomez, Juan

    2016-01-01

    Online laboratories are useful and valuable resources in high education, especially in engineering studies. This work presents a methodology to create effective laboratories for learning that interact with a Learning Management System (LMS) to achieve advanced integration. It is based on pedagogical aspects and considers not only the laboratory…

  11. Creating and Using a Computer Networking and Systems Administration Laboratory Built under Relaxed Financial Constraints

    Science.gov (United States)

    Conlon, Michael P.; Mullins, Paul

    2011-01-01

    The Computer Science Department at Slippery Rock University created a laboratory for its Computer Networks and System Administration and Security courses under relaxed financial constraints. This paper describes the department's experience designing and using this laboratory, including lessons learned and descriptions of some student projects…

  12. Flexible System Integration and Advanced Hierarchical Control Architectures in the Microgrid Research Laboratory of Aalborg University

    DEFF Research Database (Denmark)

    Meng, Lexuan; Hernández, Adriana Carolina Luna; Diaz, Enrique Rodriguez

    2016-01-01

    This paper presents the system integration and hierarchical control implementation in an inverter-based microgrid research laboratory (MGRL) in Aalborg University, Denmark. MGRL aims to provide a flexible experimental platform for comprehensive studies of microgrids. The structure of the laboratory...

  13. Design of an electronic performance support system for food chemistry laboratory classes

    NARCIS (Netherlands)

    Kolk, van der J.

    2013-01-01

    The design oriented research described in this thesis aims at designing an realizing an electronic performance support system for food chemistry laboratory classes (labEPSS). Four design goals related to food chemistry laboratory classes were identified. Firstly, labEPSS should avoid extraneous

  14. Planning an Automatic Fire Detection, Alarm, and Extinguishing System for Research Laboratories

    Directory of Open Access Journals (Sweden)

    Rostam Golmohamadi

    2014-04-01

    Full Text Available Background & Objectives: Educational and research laboratories in universities have a high risk of fire, because they have a variety of materials and equipment. The aim of this study was to provide a technical plan for safety improvement in educational and research laboratories of a university based on the design of automatic detection, alarm, and extinguishing systems . Methods : In this study, fire risk assessment was performed based on the standard of Military Risk Assessment method (MIL-STD-882. For all laboratories, detection and fire alarm systems and optimal fixed fire extinguishing systems were designed. Results : Maximum and minimum risks of fire were in chemical water and wastewater (81.2% and physical agents (62.5% laboratories, respectively. For studied laboratories, we designed fire detection systems based on heat and smoke detectors. Also in these places, fire-extinguishing systems based on CO2 were designed . Conclusion : Due to high risk of fire in studied laboratories, the best control method for fire prevention and protection based on special features of these laboratories is using automatic detection, warning and fire extinguishing systems using CO2 .

  15. A Novel General Chemistry Laboratory: Creation of Biomimetic Superhydrophobic Surfaces through Replica Molding

    Science.gov (United States)

    Verbanic, Samuel; Brady, Owen; Sanda, Ahmed; Gustafson, Carolina; Donhauser, Zachary J.

    2014-01-01

    Biomimetic replicas of superhydrophobic lotus and taro leaf surfaces can be made using polydimethylsiloxane. These replicas faithfully reproduce the microstructures of the leaves' surface and can be analyzed using contact angle goniometry, self-cleaning experiments, and optical microscopy. These simple and adaptable experiments were used to…

  16. Laboratory measurement of the interface pressures applied by active therapy support surfaces: a consensus document.

    Science.gov (United States)

    2010-02-01

    A key element in pressure ulcer prevention and management is the selection of appropriate pressure redistributing (PR) patient support surfaces for use while seated and in bed. However little explicit guidance exists allowing standardised quantitative comparison of different PR surfaces based upon their ability to redistribute pressure from anatomical landmarks such as the heels and sacrum. In 2008 a working group was established in Europe through the US National Pressure Ulcer Advisory Panel (NPUAP) support surface standardisation initiative (S3I) and under the aegis of the European Pressure Ulcer Advisory Panel with the specific remit of developing test methods for the evaluation of active therapy support surfaces (alternating pressure air mattresses). This report describes a consensus development process to agree test methods appropriate to compare active therapy surfaces based upon their ability to redistribute pressure from the sacrum and the heels. Copyright 2009 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

  17. A computer-aided surface roughness measurement system

    International Nuclear Information System (INIS)

    Hughes, F.J.; Schankula, M.H.

    1983-11-01

    A diamond stylus profilometer with computer-based data acquisitions/analysis system is being used to characterize surfaces of reactor components and materials, and to examine the effects of surface topography on thermal contact conductance. The current system is described; measurement problems and system development are discussed in general terms and possible future improvements are outlined

  18. From Beetles in Nature to the Laboratory: Actuating Underwater Locomotion on Hydrophobic Surfaces.

    Science.gov (United States)

    Pinchasik, Bat-El; Steinkühler, Jan; Wuytens, Pieter; Skirtach, Andre G; Fratzl, Peter; Möhwald, Helmuth

    2015-12-29

    The controlled wetting and dewetting of surfaces is a primary mechanism used by beetles in nature, such as the ladybird and the leaf beetle for underwater locomotion.1 Their adhesion to surfaces underwater is enabled through the attachment of bubbles trapped in their setae-covered legs. Locomotion, however, is performed by applying mechanical forces in order to move, attach, and detach the bubbles in a controlled manner. Under synthetic conditions, however, when a bubble is bound to a surface, it is nearly impossible to maneuver without the use of external stimuli. Thus, actuated wetting and dewetting of surfaces remain challenges. Here, electrowetting-on-dielectric (EWOD) is used for the manipulation of bubble-particle complexes on unpatterned surfaces. Bubbles nucleate on catalytic Janus disks adjacent to a hydrophobic surface. By changing the wettability of the surface through electrowetting, the bubbles show a variety of reactions, depending on the shape and periodicity of the electrical signal. Time-resolved (μs) imaging of bubble radial oscillations reveals possible mechanisms for the lateral mobility of bubbles on a surface under electrowetting: bubble instability is induced when electric pulses are carefully adjusted. This instability is used to control the surface-bound bubble locomotion and is described in terms of the change in surface energy. It is shown that a deterministic force applied normal can lead to a random walk of micrometer-sized bubbles by exploiting the phenomenon of contact angle hysteresis. Finally, bubble use in nature for underwater locomotion and the actuated bubble locomotion presented in this study are compared.

  19. Plexus (Phillips Laboratory Expert System-Assisted User Software)

    National Research Council Canada - National Science Library

    Myers, Thomas

    1997-01-01

    This report summarizes the results of the Phillips Lab PLEXUS project to design, build, and distribute a user friendly, expert system assisted, GUI enhanced software suite of sophisticated atmospheric...

  20. Contamination confinement system of irradiated materials handling laboratories

    International Nuclear Information System (INIS)

    Lobao, A. dos S.T.; Araujo, J.A. de; Camilo, R.L.

    1988-06-01

    A study to prevent radioctivity release in lab scale is presented. As a basis for the design all the limits established by the IAEA for ventilation systems were observed. An evaluation of the different parameters involved in the design have been made, resulting in the especification of the working areas, ducts and filtering systems in order to get the best conditions for the safe handling of irradiated materials. (author) [pt

  1. The Oak Ridge National Laboratory's Robotics and Intelligent Systems Program

    International Nuclear Information System (INIS)

    Meacham, S.A.

    1987-01-01

    The goals of the newly formed Robotics and Intelligent Systems Program are discussed. The application of the remote systems technology developed by the Consolidated Fuel Reprocessing Program for the Department of Energy is presented. The activities (satellite refueling and space station truss assembly) with the National Aeronautics and Space Administration are presented in a videotape format with narration by the presenter. The goals of technology transfer to the private sector and the potential positive impact on the community conclude the oral presentation

  2. Selection and implementation of a laboratory computer system.

    Science.gov (United States)

    Moritz, V A; McMaster, R; Dillon, T; Mayall, B

    1995-07-01

    The process of selection of a pathology computer system has become increasingly complex as there are an increasing number of facilities that must be provided and stringent performance requirements under heavy computing loads from both human users and machine inputs. Furthermore, the continuing advances in software and hardware technology provide more options and innovative new ways of tackling problems. These factors taken together pose a difficult and complex set of decisions and choices for the system analyst and designer. The selection process followed by the Microbiology Department at Heidelberg Repatriation Hospital included examination of existing systems, development of a functional specification followed by a formal tender process. The successful tenderer was then selected using predefined evaluation criteria. The successful tenderer was a software development company that developed and supplied a system based on a distributed network using a SUN computer as the main processor. The software was written using Informix running on the UNIX operating system. This represents one of the first microbiology systems developed using a commercial relational database and fourth generation language. The advantages of this approach are discussed.

  3. [Information system of the national network of public health laboratories in Peru (Netlab)].

    Science.gov (United States)

    Vargas-Herrera, Javier; Segovia-Juarez, José; Garro Nuñez, Gladys María

    2015-01-01

    Clinical laboratory information systems produce improvements in the quality of information, reduce service costs, and diminish wait times for results, among other things. In the construction process of this information system, the National Institute of Health (NIH) of Peru has developed and implemented a web-based application to communicate to health personnel (laboratory workers, epidemiologists, health strategy managers, physicians, etc.) the results of laboratory tests performed at the Peruvian NIH or in the laboratories of the National Network of Public Health Laboratories which is called NETLAB. This article presents the experience of implementing NETLAB, its current situation, perspectives of its use, and its contribution to the prevention and control of diseases in Peru.

  4. The Horonobe Underground Research Laboratory (Tentative name) Project. A program on survey and research performed from earth surface

    International Nuclear Information System (INIS)

    2001-03-01

    The Horonobe Underground Research Laboratory (Tentative name) Project under planning at Horonobe-machi by the Japan Nuclear Cycle Development Institute (JNC) is a research facility on deep underground shown in the Long-term program on research, development and application of nuclear energy (June, 1994)' (LPNE), where some researches on the deep underground targeted at sedimentary rocks are carried out. The plan on The Horonobe Underground Research Laboratory performed at Horonobe-machi' is an about 20 years plan ranging from beginning to finishing of its survey and research, which is carried out by three steps such as 'Survey and research performed from earth surface', 'Survey and research performed under excavation of road', and Survey and research performed by using the road'. The Horonobe Underground Research Laboratory is one of research facilities on deep underground shown its importance in LPNE, and carries out some researches on the deep underground at a target of the sedimentary rocks. And also The Horonobe Underground Research Laboratory confirms some technical reliability and support on stratum disposal shown in the 'Technical reliability on stratum disposal of the high level radioactive wastes. The Second Progress Report of R and D on geological disposal' summarized on November, 1999 by JNC through actual tests and researches at the deep stratum. The obtained results are intended to reflect to disposal business of The Horonobe Underground Research Laboratory and safety regulation and so on performed by the government, together with results of stratum science research, at the Tono Geoscience Center, of geological disposal R and D at the Tokai Works, or of international collaborations. For R and D at the The Horonobe Underground Research Laboratory after 2000, following subjects are shown: 1) Survey technique on long-term stability of geological environment, 2) Survey technique on geological environment, 3) Engineering technique on engineered barrier and

  5. Laboratory information management system: an example of international cooperation in Namibia.

    Science.gov (United States)

    Colangeli, Patrizia; Ferrilli, Monica; Quaranta, Fabrizio; Malizia, Elio; Mbulu, Rosa-Stella; Mukete, Esther; Iipumbu, Lukas; Kamhulu, Anna; Tjipura-Zaire, Georgina; Di Francesco, Cesare; Lelli, Rossella; Scacchia, Massimo

    2012-01-01

    The authors describe the project undertaken by the Istituto G. Caporale to provide a laboratory information management system (LIMS) to the Central Veterinary Laboratory (CVL) in Windhoek, Namibia. This robust laboratory management tool satisfies Namibia's information obligations under international quality standard ISO 17025:2005. The Laboratory Information Management System (LIMS) for Africa was designed to collect and manage all necessary information on samples, tests and test results. The system involves the entry of sample data on arrival, as required by Namibian sampling plans, the tracking of samples through the various sections of the CVL, the collection of test results, generation of test reports and monitoring of outbreaks through data interrogation functions, eliminating multiple registrations of the same data on paper records. It is a fundamental component of the Namibian veterinary information system.

  6. A direct probe of dark energy interactions with a solar System laboratory

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose a mission concept for direct detection of dark energy interactions with normal matter in a Solar System laboratory. Dark energy is the leading proposal to...

  7. Laboratory information management system: an example of international cooperation in Namibia

    Directory of Open Access Journals (Sweden)

    Patrizia Colangeli

    2012-09-01

    Full Text Available The authors describe the project undertaken by the Istituto G. Caporale to provide a laboratory information management system (LIMS to the Central Veterinary Laboratory (CVL in Windhoek, Namibia. This robust laboratory management tool satisfies Namibia’s information obligations under international quality standard ISO 17025:2005. The Laboratory Information Management System (LIMS for Africa was designed to collect and manage all necessary information on samples, tests and test results. The system involves the entry of sample data on arrival, as required by Namibian sampling plans, the tracking of samples through the various sections of the CVL, the collection of test results, generation of test reports and monitoring of outbreaks through data interrogation functions, eliminating multiple registrations of the same data on paper records. It is a fundamental component of the Namibian veterinary information system.

  8. Sandia National Laboratories, California sewer system management plan.

    Energy Technology Data Exchange (ETDEWEB)

    Holland, Robert C.

    2010-02-01

    A Sewer System Management Plan (SSMP) is required by the State Water Resources Control Board (SWRCB) Order No. 2006-0003-DWQ Statewide General Waste Discharge Requirements (WDR) for Sanitary Sewer Systems (General Permit). DOE, National Nuclear Security Administration (NNSA), Sandia Site Office has filed a Notice of Intent to be covered under this General Permit. The General Permit requires a proactive approach to reduce the number and frequency of sanitary sewer overflows (SSOs) within the State. SSMPs must include provisions to provide proper and efficient management, operation, and maintenance of sanitary sewer systems and must contain a spill response plan. Elements of this Plan are under development in accordance with the SWRCB's schedule.

  9. A laboratory facility for electric vehicle propulsion system testing

    Science.gov (United States)

    Sargent, N. B.

    1980-01-01

    The road load simulator facility located at the NASA Lewis Research Center enables a propulsion system or any of its components to be evaluated under a realistic vehicle inertia and road loads. The load is applied to the system under test according to the road load equation: F(net)=K1F1+K2F2V+K3 sq V+K4(dv/dt)+K5 sin theta. The coefficient of each term in the equation can be varied over a wide range with vehicle inertial representative of vehicles up to 7500 pounds simulated by means of flywheels. The required torque is applied by the flywheels, a hydroviscous absorber and clutch, and a drive motor integrated by a closed loop control system to produce a smooth, continuous load up to 150 horsepower.

  10. Velocity and stage data collected in a laboratory flume for water-surface slope determination using a pipe manometer

    Science.gov (United States)

    Lee, Jonathan K.; Visser, H.M.; Jenter, H.L.; Duff, M.P.

    2000-01-01

    U.S. Geological Survey (USGS) hydrologists and ecologist are conducting studies to quantify vegetative flow resistance in order to improve numerical models of surface-water flow in the Florida Everglades. Water-surface slope is perhaps the most difficult of the flow resistance parameters to measure in the Everglades due to the very low gradients of the topography and flow. In an effort to measure these very small slopes, a unique pipe manometer was developed for the local measurement of water-surface slopes on the order of 1 centimeter per kilometer (cm/km). According to theory, a very precise measurement of centerline velocity obtained inside the pipe manometer should serve as a unique proxy for water-surface slope in the direction of the pipe axis. In order to confirm this theoretical relationship and calibrate the pipe manometer, water-surface elevation and pipe centerline velocity data were simultaneously measured in a set of experiments carried out in the tilting flume at the USGS Hydraulic Laboratory Facility at Stennis Space Center, Mississippi. A description of the instrumentation and methods used to evaluate this technique for measuring water-surface slope as well as a summary of the entire data set is presented.

  11. Equipment Proposal for the Autonomous Vehicle Systems Laboratory at UIW

    Science.gov (United States)

    2015-04-29

    testing, 5) 38 Lego Mindstorm EV3 and Hitechnic Sensors for use in feedback control and autonomous systems for STEM undergraduate and High School...autonomous robots using the Lego Mindstorm EV3. This robotics workshop will be used as a pilot study for next summer when more High School students

  12. A computerised EEG-analyzing system for small laboratory animals

    NARCIS (Netherlands)

    Kropveld, D.; Chamuleau, R. A.; Popken, R. J.; Smith, J.

    1983-01-01

    The experimental setup, including instrumentation and software packaging, is described for the use of a minicomputer as an on-line analyzing system of the EEG in rats. Complete fast Fourier transformation of the EEG sampled in 15 episodes of 10 s each is plotted out within 7 min after the start of

  13. Concrete-Ice Abrasion: Laboratory Studies using a Sawn Concrete Surfac

    OpenAIRE

    Shamsutdinova, Guzel; Hendriks, Max; Jacobsen, Stefan

    2017-01-01

    Concrete-ice abrasion is a surface degradation mechanism due to ice-structure interaction especially relevant for concrete gravity-based structures in the Arctic offshore. Experiment is the main evaluation method for concrete durability against ice abrasion. The paper presents NTNUs lab facilities and a 4 km concrete-ice abrasion test between a sawn concrete surface with fc cube = 110 MPa and unidirectionally grown fresh water ice. Results demonstrate the load cells response, coefficient of f...

  14. Impact of laboratory accreditation on patient care and the health system.

    Science.gov (United States)

    Peter, Trevor F; Rotz, Philip D; Blair, Duncan H; Khine, Aye-Aye; Freeman, Richard R; Murtagh, Maurine M

    2010-10-01

    Accreditation is emerging as a preferred framework for building quality medical laboratory systems in resource-limited settings. Despite the low numbers of laboratories accredited to date, accreditation has the potential to improve the quality of health care for patients through the reduction of testing errors and attendant decreases in inappropriate treatment. Accredited laboratories can become more accountable and less dependent on external support. Efforts made to achieve accreditation may also lead to improvements in the management of laboratory networks by focusing attention on areas of greatest need and accelerating improvement in areas such as supply chain, training, and instrument maintenance. Laboratory accreditation may also have a positive influence on performance in other areas of health care systems by allowing laboratories to demonstrate high standards of service delivery. Accreditation may, thus, provide an effective mechanism for health system improvement yielding long-term benefits in the quality, cost-effectiveness, and sustainability of public health programs. Further studies are needed to strengthen the evidence on the benefits of accreditation and to justify the resources needed to implement accreditation programs aimed at improving the performance of laboratory systems.

  15. Proceedings of the National Renewable Energy Laboratory Wind Energy Systems Engineering Workshop

    Energy Technology Data Exchange (ETDEWEB)

    Dykes, K.

    2014-12-01

    The second National Renewable Energy Laboratory (NREL) Wind Energy Systems Engineering Workshop was held in Broomfield, Colorado, from January 29 to February 1, 2013. The event included a day-and-a-half workshop exploring a wide variety of topics related to system modeling and design of wind turbines and plants. Following the workshop, 2 days of tutorials were held at NREL, showcasing software developed at Sandia National Laboratories, the National Aeronautics and Space Administration's Glenn Laboratories, and NREL. This document provides a brief summary of the various workshop activities and includes a review of the content and evaluation results from attendees.

  16. In situ surface-enhanced Raman spectroelectrochemical analysis system with a hemin modified nanostructured gold surface

    NARCIS (Netherlands)

    Yuan, Tao; Le Thi Ngoc, Loan; van Nieuwkasteele, Jan; Odijk, Mathieu; van den Berg, Albert; Permentier, Hjalmar; Bischoff, Rainer; Carlen, Edwin T

    2015-01-01

    An integrated surface-enhanced Raman scattering (SERS) spectroelectrochemical (SEC) analysis system is presented that combines a small volume microfluidic sample chamber (<100 μL) with a compact three-electrode configuration for in situ surface-enhanced Raman spectroelectrochemistry. The SEC system

  17. Laboratory Calibration of a Field Imaging Spectrometer System

    Directory of Open Access Journals (Sweden)

    Qingxi Tong

    2011-02-01

    Full Text Available A new Field Imaging Spectrometer System (FISS based on a cooling area CCD was developed. This paper describes the imaging principle, structural design, and main parameters of the FISS sensor. The FISS was spectrally calibrated with a double grating monochromator to determine the center wavelength and FWHM of each band. Calibration results showed that the spectral range of the FISS system is 437–902 nm, the number of channels is 344 and the spectral resolution of each channel is better than 5 nm. An integrating sphere was used to achieve absolute radiometric calibration of the FISS with less than 5% calibration error for each band. There are 215 channels with signal to noise ratios (SNRs greater than 500 (62.5% of the bands. The results demonstrated that the FISS has achieved high performance that assures the feasibility of its practical use in various fields.

  18. HVAC systems in a field laboratory for indoor climate study

    DEFF Research Database (Denmark)

    Fang, Lei; Melikov, Arsen Krikor; Olesen, Bjarne W.

    2012-01-01

    convectors. The field lab was designed for experimental research, education and demonstration of ventilation and air-conditioning principals with special focus on studying the impact of different air distribution and heating/cooling methods on human comfort and health. The system can also be used for testing......This paper presents the design of a HVAC system for a field lab. The design integrated mixing ventilation, displacement ventilation, low impulse vertical ventilation, personalized ventilation, natural ventilation, hybrid ventilation, active chilled beams, radiant ceiling and floor, and heat...... under realistic conditions the performance of air processing units (e.g. a special air handling unit, an air cleaning devices, etc.) including their energy consumption and human response. The field lab can accommodate up to 50 occupants and supply 750 L/s of conditioned outdoor fresh air...

  19. Role of a quality management system in improving patient safety - laboratory aspects.

    Science.gov (United States)

    Allen, Lynn C

    2013-09-01

    The aim of this study is to describe how implementation of a quality management system (QMS) based on ISO 15189 enhances patient safety. A literature review showed that several European hospitals implemented a QMS based on ISO 9001 and assessed the impact on patient safety. An Internet search showed that problems affecting patient safety have occurred in a number of laboratories across Canada. The requirements of a QMS based on ISO 15189 are outlined, and the impact of the implementation of each requirement on patient safety is summarized. The Quality Management Program - Laboratory Services in Ontario is briefly described, and the experience of Ontario laboratories with Ontario Laboratory Accreditation, based on ISO 15189, is outlined. Several hospitals that implemented ISO 9001 reported either a positive impact or no impact on patient safety. Patient safety problems in Canadian laboratories are described. Implementation of each requirement of the QMS can be seen to have a positive effect on patient safety. Average laboratory conformance on Ontario Laboratory Accreditation is very high, and laboratories must address and resolve any nonconformities. Other standards, practices, and quality requirements may also contribute to patient safety. Implementation of a QMS based on ISO 15189 provides a solid foundation for quality in the laboratory and enhances patient safety. It helps to prevent patient safety issues; when such issues do occur, effective processes are in place for investigation and resolution. Patient safety problems in Canadian laboratories might have been prevented had effective QMSs been in place. Ontario Laboratory Accreditation has had a positive impact on quality in Ontario laboratories. Copyright © 2013 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  20. Surface nucleation in complex rheological systems

    Science.gov (United States)

    Herfurth, J.; Ulrich, J.

    2017-07-01

    Forced nucleation induced by suitable foreign seeds is an important tool to control the production of defined crystalline products. The quality of a surface provided by seed materials represents an important variable in the production of crystallizing layers that means for the nucleation process. Parameters like shape and surface structure, size and size distribution of the seed particles as well as the ability to hold up the moisture (the solvent), can have an influence on the nucleation process of different viscous supersaturated solutions. Here the properties of different starch powders as seeds obtained from corn, potato, rice, tapioca and wheat were tested. It could be found, that the best nucleation behavior of a sugar solution could be reached with the use of corn starch as seed material. Here the surface of the crystallized sugar layer is smooth, crystallization time is short (<3 h) and the shape of the product is easily reproducible. Beneficial properties of seed materials are therefore an edged, uneven surface, small particle sizes as well as low moisture content at ambient conditions within the seed materials.

  1. Massive Modularity of Space and Surface Systems

    Data.gov (United States)

    National Aeronautics and Space Administration — This project will conduct a systems level investigation of a modular design and operations approach for future NASA exploration systems. Particular emphasis will be...

  2. Quality assurance for systems at the Lawrence Livermore Laboratory tritium facility

    International Nuclear Information System (INIS)

    Dow, J.P.

    1976-01-01

    A quality-assurance program for tritium-handling systems at the Lawrence Livermore Laboratory tritium facility has been developed. Operational guidelines governing system design, construction, and testing have been written. A certified-material storeroom has been established to procure and distribute high-quality materials. Ten systems are currently being modified under the new guidelines

  3. Laboratory Information Systems in Molecular Diagnostics: Why Molecular Diagnostics Data are Different.

    Science.gov (United States)

    Lee, Roy E; Henricks, Walter H; Sirintrapun, Sahussapont J

    2016-03-01

    Molecular diagnostic testing presents new challenges to information management that are yet to be sufficiently addressed by currently available information systems for the molecular laboratory. These challenges relate to unique aspects of molecular genetic testing: molecular test ordering, informed consent issues, diverse specimen types that encompass the full breadth of specimens handled by traditional anatomic and clinical pathology information systems, data structures and data elements specific to molecular testing, varied testing workflows and protocols, diverse instrument outputs, unique needs and requirements of molecular test reporting, and nuances related to the dissemination of molecular pathology test reports. By satisfactorily addressing these needs in molecular test data management, a laboratory information system designed for the unique needs of molecular diagnostics presents a compelling reason to migrate away from the current paper and spreadsheet information management that many molecular laboratories currently use. This paper reviews the issues and challenges of information management in the molecular diagnostics laboratory.

  4. THE EFFECTS OF CRACKING ON THE SURFACE POTENTIAL OF ICY GRAINS IN SATURN’S E-RING: LABORATORY STUDIES

    Energy Technology Data Exchange (ETDEWEB)

    Bu, Caixia; Bahr, David A.; Dukes, Catherine A.; Baragiola, Raúl A., E-mail: cb8nw@virginia.edu [Laboratory for Astrophysics and Surface Physics, Materials Science and Engineering, University of Virginia, Charlottesville, VA 22904 (United States)

    2016-07-10

    Within Saturn's E-ring, dust grains are coated by water vapor co-released with ice grains from the geyser-like eruptions of Enceladus. These ice-coated grains have intrinsic surface potential and interact synergistically with the ions and electrons of Saturn's magnetospheric plasmas. We perform laboratory experiments to investigate the effects of water-ice growth on the surface potential, using amorphous solid water (ASW) films. We estimate the growth of the surface potential to be ∼ 2.5 mV (Earth) yr{sup 1} and 112 mV yr{sup 1} for E-ring grains at ∼4.5 R {sub s} and 3.95 R {sub s} outside Enceladus’s plume, respectively. In addition, our measurements show that the linear relationship between the surface potential and the film thickness, as described in previous studies, has an upper limit, where the film spontaneously cracks above a porosity-dependent critical thickness. Heating of the cracked films with (and without) deposited charge shows that significant positive (and negative) surface potentials are retained at temperatures above 110 K, contrary to the minimal values (roughly zero) for thin, transparent ASW films. The significant surface potentials observed on micron-scale cracked ice films after thermal cycling, (5–20) V, are consistent with Cassini measurements, which indicate a negative charge of up to 5 V for E-ring dust particles at ∼5 R {sub s}. Therefore, the native grain surface potential resulting from water-vapor coating must be included in modeling studies of interactions between E-ring icy surfaces and Saturn's magnetospheric plasma.

  5. Sandia National Laboratories Electrochemical Storage System Abuse Test Procedure Manual

    Energy Technology Data Exchange (ETDEWEB)

    Unkelhaeuser, Terry; Smallwood David

    1999-07-01

    The series of tests described in this report are intended to simulate actual use and abuse conditions and internally initiated failures that may be experienced in electrochemical storage systems (ECSS). These tests were derived from Failure Mode and Effect Analysis, user input, and historical abuse testing. The tests are to provide a common framework for various ECSS technologies. The primary purpose of testing is to gather response information to external/internal inputs. Some tests and/or measurements may not be required for some ECSS technologies and designs if it is demonstrated that a test is not applicable, and the measurements yield no useful information.

  6. The laboratory health system and its response to the Ebola virus disease outbreak in Liberia

    Directory of Open Access Journals (Sweden)

    Stephen B. Kennedy

    2016-10-01

    Full Text Available The laboratory system in Liberia has generally been fragmented and uncoordinatedAccordingly, the country’s Ministry of Health established the National Reference Laboratoryto strengthen and sustain laboratory services. However, diagnostic testing services were oftenlimited to clinical tests performed in health facilities, with the functionality of the NationaReference Laboratory restricted to performing testing services for a limited number ofepidemic-prone diseases. The lack of testing capacity in-country for Lassa fever and otherhaemorrhagic fevers affected the response of the country’s health system during the onset ofthe Ebola virus disease (EVD outbreak. Based on the experiences of the EVD outbreak, effortswere initiated to strengthen the laboratory system and infrastructure, enhance human resourcecapacity, and invest in diagnostic services and public health surveillance to inform admittancetreatment, and discharge decisions. In this article, we briefly describe the pre-EVD laboratorycapability in Liberia, and extensively explore the post-EVD strengthening initiatives to enhancecapacity, mobilise resources and coordinate disaster response with international partners torebuild the laboratory infrastructure in the country. Now that the EVD outbreak has endedadditional initiatives are needed to revise the laboratory strategic and operational plan forpost-EVD relevance, promote continual human resource capacity, institute accreditation andvalidation programmes, and coordinate the investment strategy to strengthen and sustain thepreparedness of the laboratory sector to mitigate future emerging and re-emerging infectiousdiseases.

  7. MASTR-MS: a web-based collaborative laboratory information management system (LIMS) for metabolomics.

    Science.gov (United States)

    Hunter, Adam; Dayalan, Saravanan; De Souza, David; Power, Brad; Lorrimar, Rodney; Szabo, Tamas; Nguyen, Thu; O'Callaghan, Sean; Hack, Jeremy; Pyke, James; Nahid, Amsha; Barrero, Roberto; Roessner, Ute; Likic, Vladimir; Tull, Dedreia; Bacic, Antony; McConville, Malcolm; Bellgard, Matthew

    2017-01-01

    An increasing number of research laboratories and core analytical facilities around the world are developing high throughput metabolomic analytical and data processing pipelines that are capable of handling hundreds to thousands of individual samples per year, often over multiple projects, collaborations and sample types. At present, there are no Laboratory Information Management Systems (LIMS) that are specifically tailored for metabolomics laboratories that are capable of tracking samples and associated metadata from the beginning to the end of an experiment, including data processing and archiving, and which are also suitable for use in large institutional core facilities or multi-laboratory consortia as well as single laboratory environments. Here we present MASTR-MS, a downloadable and installable LIMS solution that can be deployed either within a single laboratory or used to link workflows across a multisite network. It comprises a Node Management System that can be used to link and manage projects across one or multiple collaborating laboratories; a User Management System which defines different user groups and privileges of users; a Quote Management System where client quotes are managed; a Project Management System in which metadata is stored and all aspects of project management, including experimental setup, sample tracking and instrument analysis, are defined, and a Data Management System that allows the automatic capture and storage of raw and processed data from the analytical instruments to the LIMS. MASTR-MS is a comprehensive LIMS solution specifically designed for metabolomics. It captures the entire lifecycle of a sample starting from project and experiment design to sample analysis, data capture and storage. It acts as an electronic notebook, facilitating project management within a single laboratory or a multi-node collaborative environment. This software is being developed in close consultation with members of the metabolomics research

  8. From Concept-to-Flight: An Active Active Fluid Loop Based Thermal Control System for Mars Science Laboratory Rover

    Science.gov (United States)

    Birur, Gajanana C.; Bhandari, Pradeep; Bame, David; Karlmann, Paul; Mastropietro, A. J.; Liu, Yuanming; Miller, Jennifer; Pauken, Michael; Lyra, Jacqueline

    2012-01-01

    The Mars Science Laboratory (MSL) rover, Curiosity, which was launched on November 26, 2011, incorporates a novel active thermal control system to keep the sensitive electronics and science instruments at safe operating and survival temperatures. While the diurnal temperature variations on the Mars surface range from -120 C to +30 C, the sensitive equipment are kept within -40 C to +50 C. The active thermal control system is based on a single-phase mechanically pumped fluid loop (MPFL) system which removes or recovers excess waste heat and manages it to maintain the sensitive equipment inside the rover at safe temperatures. This paper will describe the entire process of developing this active thermal control system for the MSL rover from concept to flight implementation. The development of the rover thermal control system during its architecture, design, fabrication, integration, testing, and launch is described.

  9. A Laboratory Experimental Study: An FBG-PVC Tube Integrated Device for Monitoring the Slip Surface of Landslides.

    Science.gov (United States)

    Wang, Kai; Zhang, Shaojie; Chen, Jiang; Teng, Pengxiao; Wei, Fangqiang; Chen, Qiao

    2017-10-30

    A new detection device was designed by integrating fiber Bragg grating (FBG) and polyvinyl chloride (PVC) tube in order to monitor the slip surface of a landslide. Using this new FBG-based device, a corresponding slope model with a pre-set slip surface was designed, and seven tests with different soil properties were carried out in laboratory conditions. The FBG sensing fibers were fixed on the PVC tube to measure strain distributions of PVC tube at different elevation. Test results indicated that the PVC tube could keep deformation compatible with soil mass. The new device was able to monitor slip surface location before sliding occurrence, and the location of monitored slip surface was about 1-2 cm above the pre-set slip surface, which basically agreed with presupposition results. The monitoring results are expected to be used to pre-estimate landslide volume and provide a beneficial option for evaluating the potential impact of landslides on shipping safety in the Three Gorges area.

  10. Evaluation of Cavity Collapse and Surface Crater Formation for Selected Lawrence Livermore National Laboratory Underground Nuclear Tests - 2010

    Energy Technology Data Exchange (ETDEWEB)

    Pawloski, G A

    2011-01-03

    This report evaluates collapse evolution for selected Lawrence Livermore National Laboratory (LLNL) underground nuclear tests at the Nevada National Security Site (NNSS, formerly called the Nevada Test Site). The work is being done at the request of Navarro-Interra LLC, and supports environmental restoration efforts by the Department of Energy, National Nuclear Security Administration for the Nevada Site Office. Safety decisions must be made before a surface crater area, or potential surface crater area, can be reentered for any work. Our statements on cavity collapse and surface crater formation are input into their safety decisions. These statements do not include the effects of erosion that may modify the surface collapse craters over time. They also do not address possible radiation dangers that may be present. Subject matter experts from the LLNL Containment Program who had been active in weapons testing activities performed these evaluations. Information used included drilling and hole construction, emplacement and stemming, timing and sequence of the selected test and nearby tests, geology, yield, depth of burial, collapse times, surface crater sizes, cavity and crater volume estimations, and ground motion. Both classified and unclassified data were reviewed. Various amounts of information are available for these tests, depending on their age and other associated activities. Lack of data can hamper evaluations and introduce uncertainty. We make no attempt to quantify this uncertainty.

  11. Note: Measurement system for the radiative forcing of greenhouse gases in a laboratory scale.

    Science.gov (United States)

    Kawamura, Yoshiyuki

    2016-01-01

    The radiative forcing of the greenhouse gases has been studied being based on computational simulations or the observation of the real atmosphere meteorologically. In order to know the greenhouse effect more deeply and to study it from various viewpoints, the study on it in a laboratory scale is important. We have developed a direct measurement system for the infrared back radiation from the carbon dioxide (CO2) gas. The system configuration is similar with that of the practical earth-atmosphere-space system. Using this system, the back radiation from the CO2 gas was directly measured in a laboratory scale, which roughly coincides with meteorologically predicted value.

  12. [Systemic lupus erythematosus in the aged: clinical and laboratory characteristics].

    Science.gov (United States)

    Takayasu, V; Bonfá, E; Levy Neto, M; Kumeda, C; Daud, R M; Cossermelli, W

    1992-01-01

    The clinical and serologic characteristics of 199 systemic lupus erythematosus patients with early and late onset of disease were compared to determine if the disease in the older age group defines a specific subset of SLE. This study demonstrated that SLE in the elderly patients exhibits peculiar clinical features with a high frequency of muscular involvement (p manifestations (p manifestation was muscular pain and stiffness, arthritis and weight loss (over 10 kg). This condition is often hard to distinguish from polymyalgia rheumatica or underlying malignancy. The frequency of autoantibodies was similar in both groups. The absence of anti-La was surprising, however it was confirmed by "Western blotting". The symptoms of late onset SLE are not very prominent however the diagnosis should be considered in order to avoid delays in treatment.

  13. LINA: a laboratory inventory system for oligonucleotides, microbial strains, and cell lines.

    Science.gov (United States)

    Yousef, A F; Baggili, I M; Bartlett, G; Kane, M D; Mymryk, J S

    2011-02-01

    In this article, we present the Laboratory Inventory Network Application (LINA), a software system that assists research laboratories in keeping track of their collections of biologically relevant materials. This open source application uses relational Microsoft Access database technology as a back end and a Microsoft .NET application as a front end. Preconstructed table templates are provided that contain standardized and customizable data fields. As new samples are added to the inventory, each is provided with a unique laboratory identifier, which is assigned automatically and sequentially, allowing rapid retrieval when a given reagent is required. The LINA contains a number of useful search tools including a general search, which allows database searches using up to four user-defined criteria. The LINA represents an easily implemented and useful organizational tool for biological laboratories with large numbers of strains, clones, or other reagents. Copyright © 2011 Society for Laboratory Automation and Screening. All rights reserved.

  14. Regolith Advanced Surface Systems Operations Robot (RASSOR)

    Science.gov (United States)

    Mueller, Robert P.; Smith, Jonathan D.; Cox, Rachel E.; Schuler, Jason M.; Ebert, Tom; Nick, Andrew J.

    2012-01-01

    Regolith is abundant on extra-terrestrial surfaces and is the source of many resources such as oxygen, hydrogen, titanium, aluminum, iron, silica and other valuable materials, which can be used to make rocket propellant, consumables for life support, radiation protection barrier shields, landing pads, blast protection berms, roads, habitats and other structures and devices. Recent data from the Moon also indicates that there are substantial deposits of water ice in permanently shadowed crater regions and possibly under an over burden of regolith. The key to being able to use this regolith and acquire the resources, is being able to manipulate it with robotic excavation and hauling machinery that can survive and operate in these very extreme extra-terrestrial surface environments. In addition, the reduced gravity on the Moon, Mars, comets and asteroids poses a significant challenge in that the necessary reaction force for digging cannot be provided by the robot's weight as is typically done on Earth. Space transportation is expensive and limited in capacity, so small, lightweight payloads are desirable, which means large traditional excavation machines are not a viable option. A novel, compact and lightweight excavation robot prototype for manipulating, excavating, acquiring, hauling and dumping regolith on extra-terrestrial surfaces has been developed and tested. Lessons learned and test results will be presented including digging in a variety of lunar regolith simulant conditions including frozen regolith mixed with water ice.

  15. The Dark Matter Time Projection Chamber 4Shooter directional dark matter detector: Calibration in a surface laboratory

    International Nuclear Information System (INIS)

    Battat, James B.R.; Deaconu, Cosmin; Druitt, Gabriela; Eggleston, Richard; Fisher, Peter; Giampa, Pietro; Gregoric, Vincent; Henderson, Shawn; Jaegle, Igal; Lawhorn, Jay; Lopez, Jeremy P.; Monroe, Jocelyn; Recine, Kristen A.; Strandberg, Adam; Tomita, Hidefumi; Vahsen, Sven; Wellenstein, Hermann

    2014-01-01

    The 4Shooter is a prototype dark matter detector built by the Dark Matter Time Projection Chamber (DMTPC) collaboration. The aim of the collaboration is to observe dark matter with directional sensitivity by measuring the recoil directions of nuclei struck by dark matter particles. The 4Shooter is a single time projection chamber containing CF 4 gas, with both optical (CCD and photomultiplier tube) and charge readout. This paper describes the 4Shooter and presents results from the commissioning of the detector in a surface laboratory

  16. Mars' surface radiation environment measured with the Mars science laboratory's curiosity rover

    NARCIS (Netherlands)

    Hassler, D.M.; Zeitlin, C.; Wimmer-Schweingruber, R.F.; Ehresmann, B.; Rafkin, S.; Eigenbrode, J.L.; Brinza, D.E.; Weigle, G.; Böttcher, S.; Böhm, E.; Burmeister, S.; Guo, J.; Köhler, J.; Martin, C.; Reitz, G.; Cucinotta, F.A.; Kim, M.-H.; Grinspoon, D.; Bullock, M.A.; Posner, A.; Gómez-Elvira, J.; Vasavada, A.; Grotzinger, J.P.; MSL Science Team, the|info:eu-repo/dai/nl/292012217

    2014-01-01

    The Radiation Assessment Detector (RAD) on the Mars Science Laboratory’s Curiosity rover began making detailed measurements of the cosmic ray and energetic particle radiation environment on the surface of Mars on 7 August 2012. We report and discuss measurements of the absorbed dose and dose

  17. Critical laboratory and field evaluation of selected surface prospecting techniques for locating oil and natural gas

    Energy Technology Data Exchange (ETDEWEB)

    Heemstra, R.J.; Ray, R.M.; Wesson, T.C.; Abrams, J.R.; Moore, G.A.

    1979-01-01

    The theoretical basis for the radiation HALO method in geochemical exploration for oil and gas is largely unproven but has been covered extensively in the literature. An evaluation of the method was conducted by direct field examination of some of the variables. The variables chosen were surface radiometry, magnetometry, gravity, and near-surface soil sampling. The radiometry included measurements of potassium-40, thallium-208, and bismuth-214. The near-surface soil samples were analyzed for light hydrocarbon gases through C-4, pH, conductivity, surface area, and moisture. Statistical evaluation and comparisons of these variables were made by computer from their data bases. High correlations between variables were confirmed by comparisons of contour maps on transparent overlays. The highest positive correlations were between the five normal gases over the entire eighteen-section map. A distinct relationship was found between conductivity, pH, and the five normal gases. The role of field topography was also found to be significant. No relationship between the hydrocarbon and radiometric anomalies could be found. Radiometric patterns were heavily influenced, however, by the topographic features.

  18. Optical Verification Laboratory Demonstration System for High Security Identification Cards

    Science.gov (United States)

    Javidi, Bahram

    1997-01-01

    Document fraud including unauthorized duplication of identification cards and credit cards is a serious problem facing the government, banks, businesses, and consumers. In addition, counterfeit products such as computer chips, and compact discs, are arriving on our shores in great numbers. With the rapid advances in computers, CCD technology, image processing hardware and software, printers, scanners, and copiers, it is becoming increasingly easy to reproduce pictures, logos, symbols, paper currency, or patterns. These problems have stimulated an interest in research, development and publications in security technology. Some ID cards, credit cards and passports currently use holograms as a security measure to thwart copying. The holograms are inspected by the human eye. In theory, the hologram cannot be reproduced by an unauthorized person using commercially-available optical components; in practice, however, technology has advanced to the point where the holographic image can be acquired from a credit card-photographed or captured with by a CCD camera-and a new hologram synthesized using commercially-available optical components or hologram-producing equipment. Therefore, a pattern that can be read by a conventional light source and a CCD camera can be reproduced. An optical security and anti-copying device that provides significant security improvements over existing security technology was demonstrated. The system can be applied for security verification of credit cards, passports, and other IDs so that they cannot easily be reproduced. We have used a new scheme of complex phase/amplitude patterns that cannot be seen and cannot be copied by an intensity-sensitive detector such as a CCD camera. A random phase mask is bonded to a primary identification pattern which could also be phase encoded. The pattern could be a fingerprint, a picture of a face, or a signature. The proposed optical processing device is designed to identify both the random phase mask and the

  19. Ion Beam and Plasma Technology Development for Surface Modification at Los Alamos National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Davis, H.A.; Munson, C.P.; Wood, B.P.; Bitteker, L.J.; Nastasi, M.A.; Rej, D.J.; Waganaar, W.J.; Walter, K.C. [Los Alamos National Lab., NM (United States); Coates, D.M.; Schleinitz, H.M. [DuPont Central Research and Development, Wilmington, DE (United States)

    1997-12-31

    We are developing two high-throughput technologies for materials modification. The first is a repetitive intense ion beam source for materials modification through rapid surface melt and resolidification (up to 10{sup 10} deg/sec cooling rates) and for ablative deposition of coatings. The short range of the ions (typically 0.1 to 5 micrometers) allows vaporization or melting at moderate beam energy density (typically 1-50 J/cm{sup 2}). A new repetitive intense ion beam accelerator called CHAMP is under development at Los Alamos. The design beam parameters are: E=200 keV, I=15 kA, {tau}=1 {micro}s, and 1 Hz. This accelerator will enable applications such as film deposition, alloying and mixing, cleaning and polishing, corrosion and wear resistance, polymer surface treatments, and nanophase powder synthesis. The second technology is plasma source ion implantation (PSII) using plasmas generated from both gas phase (using radio frequency excitation) and solid phase (using a cathodic arc) sources. We have used PSII to directly implant ions for surface modification or as method for generating graded interfaces to enhance the adhesion of surface coatings. Surfaces with areas of up to 16 m{sup 2} and weighing more than a thousand kilograms have been treated in the Los Alamos PSII chamber. In addition, PSII in combination with cathodic source deposition has been used to form highly adherent, thick Er{sub 2}O{sub 3} coatings on steel for reactive metal containment in casting. These coatings resist delamination under extreme mechanical and thermal stress.

  20. Reference reactor module for NASA's lunar surface fission power system

    International Nuclear Information System (INIS)

    Poston, David I.; Kapernick, Richard J.; Dixon, David D.; Werner, James; Qualls, Louis; Radel, Ross

    2009-01-01

    Surface fission power systems on the Moon and Mars may provide the first US application of fission reactor technology in space since 1965. The Affordable Fission Surface Power System (AFSPS) study was completed by NASA/DOE to determine the cost of a modest performance, low-technical risk surface power system. The AFSPS concept is now being further developed within the Fission Surface Power (FSP) Project, which is a near-term technology program to demonstrate system-level TRL-6 by 2013. This paper describes the reference FSP reactor module concept, which is designed to provide a net power of 40 kWe for 8 years on the lunar surface; note, the system has been designed with technologies that are fully compatible with a Martian surface application. The reactor concept uses stainless-steel based. UO 2 -fueled, pumped-NaK fission reactor coupled to free-piston Stirling converters. The reactor shielding approach utilizes both in-situ and launched shielding to keep the dose to astronauts much lower than the natural background radiation on the lunar surface. The ultimate goal of this work is to provide a 'workhorse' power system that NASA can utilize in near-term and future Lunar and Martian mission architectures, with the eventual capability to evolve to very high power, low mass systems, for either surface, deep space, and/or orbital missions.

  1. Surface radiological investigation of Trench 5 in Waste Area Grouping 7 at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    Goff, D.D.

    1991-08-01

    A surface radiological investigation of areas encompassing Trench 5 on the Oak Ridge Reservation (ORR) was conducted from May 1990 through November 1990. This survey was led by the author, assisted by various members of the Measurement Applications and Development (MAD) group of the Health and Safety Research Division (HASRD) of Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee. The purpose of the investigation was to determine the presence, nature, and extent of surface radiological contamination at Trench 5, the Homogeneous Reactor Experiment fuel wells, and surrounding areas. Based on the data obtained in the field, interim corrective measures were recommended to limit human exposure to radioactivity and to minimize insult to the environment. It should be stressed that this project was not intended to be a complete site characterization but rather to be a preliminary investigation into the potential contamination problem that might exist as a result of past operations at Trench 5

  2. Surface radiological investigation of Trench 5 in Waste Area Grouping 7 at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    Goff, D.D.

    1991-08-01

    A surface radiological investigation of areas encompassing Trench 5 on the Oak Ridge Reservation (ORR) was conducted from May 1990 through November 1990. This survey was led by the author, assisted by various members of the Measurement Applications and Development (MAD) group of the Health and Safety Research Division (HASRD) of Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee. The purpose of the investigation was to determine the presence, nature, and extent of surface radiological contamination at Trench 5, the Homogeneous Reactor Experiment fuel wells, and surrounding areas. Based on the data obtained in the field, interim corrective measures were recommended to limit human exposure to radioactivity and to minimize insult to the environment. It should be stressed that this project was not intended to be a complete site characterization but rather to be a preliminary investigation into the potential contamination problem that might exist as a result of past operations at Trench 5.

  3. Implementation of a configurable laboratory information management system for use in cellular process development and manufacturing.

    Science.gov (United States)

    Russom, Diana; Ahmed, Amira; Gonzalez, Nancy; Alvarnas, Joseph; DiGiusto, David

    2012-01-01

    Regulatory requirements for the manufacturing of cell products for clinical investigation require a significant level of record-keeping, starting early in process development and continuing through to the execution and requisite follow-up of patients on clinical trials. Central to record-keeping is the management of documentation related to patients, raw materials, processes, assays and facilities. To support these requirements, we evaluated several laboratory information management systems (LIMS), including their cost, flexibility, regulatory compliance, ongoing programming requirements and ability to integrate with laboratory equipment. After selecting a system, we performed a pilot study to develop a user-configurable LIMS for our laboratory in support of our pre-clinical and clinical cell-production activities. We report here on the design and utilization of this system to manage accrual with a healthy blood-donor protocol, as well as manufacturing operations for the production of a master cell bank and several patient-specific stem cell products. The system was used successfully to manage blood donor eligibility, recruiting, appointments, billing and serology, and to provide annual accrual reports. Quality management reporting features of the system were used to capture, report and investigate process and equipment deviations that occurred during the production of a master cell bank and patient products. Overall the system has served to support the compliance requirements of process development and phase I/II clinical trial activities for our laboratory and can be easily modified to meet the needs of similar laboratories.

  4. The LLNL Multiuser Tandem Laboratory computer-controlled radiation monitoring system

    International Nuclear Information System (INIS)

    Homann, S.G.

    1992-01-01

    The Physics Department of the Lawrence Livermore National Laboratory (LLNL) recently constructed a Multiuser Tandem Laboratory (MTL) to perform a variety of basic and applied measurement programs. The laboratory and its research equipment were constructed with support from a consortium of LLNL Divisions, Sandia National Laboratories Livermore, and the University of California. Primary design goals for the facility were inexpensive construction and operation, high beam quality at a large number of experimental stations, and versatility in adapting to new experimental needs. To accomplish these goals, our main design decisions were to place the accelerator in an unshielded structure, to make use of reconfigured cyclotrons as effective switching magnets, and to rely on computer control systems for both radiological protection and highly reproducible and well-characterized accelerator operation. This paper addresses the radiological control computer system

  5. Implementation of ISO 28218 quality system in the laboratory of body radioactivity counter CIEMAT

    International Nuclear Information System (INIS)

    Navarro Amaro, J. F.; Perez Lopez, B.; Lopez Ponte, M. A.; Perez Jimenez, C.

    2011-01-01

    The laboratory of body radioactivity counter has implemented IS0 28218 standard Performance Criteria for Radio bioassay in all measured in vivo techniques of internal contamination in the human organism in monitoring programs defined by the Personal Dosimetry Service Internal CIEMAT. The application of this rule in the laboratory's quality system is essential to meet the technical requirements of the standard IS0/IEC 17025 with the purpose of obtaining ENAC accreditation as a testing laboratory and calibration within the framework of the accreditation of Service CIEMAT Radiation Dosimetry. (Author)

  6. Laboratory hyperspectral studies of ice/regolith associations. Application to icy surfaces on Mars.

    Science.gov (United States)

    Yoldi, Z.; Pommerol, A.; Poch, O.; Cerubini, R.; Thomas, N.

    2017-09-01

    Water and carbon dioxide ices are present on Mars under various forms: grains, slab, frosts, inter/intra/areal mixtures, etc. In order to detect and characterize them, their VIS-NIR spectro-photometric are being studied by instruments such as OMEGA, CRISM, HRSC, HiRISE and soon CaSSIS. We provide hyperspectral laboratory data of water and carbon dioxide pure ices as well as mixed with Martian regolith simulant. We analyze the spectral signatures of every sample, studying how we would detect them from orbit. We also simulate the colours of our samples as CaSSIS would see them, to assess the filter combinations that will be more efficient when aiming different targets (i.e, ice or minerals).

  7. Ground and surface water for drinking: a laboratory study on genotoxicity using plant tests

    Directory of Open Access Journals (Sweden)

    Donatella Feretti

    2012-02-01

    Full Text Available Surface waters are increasingly utilized for drinking water because groundwater sources are often polluted. Several monitoring studies have detected the presence of mutagenicity in drinking water, especially from surface sources due to the reaction of natural organic matter with disinfectant. The study aimed to investigate the genotoxic potential of the products of reaction between humic substances, which are naturally present in surface water, and three disinfectants: chlorine dioxide, sodium hypochlorite and peracetic acid. Commercial humic acids dissolved in distilled water at different total organic carbon (TOC concentrations were studied in order to simulate natural conditions of both ground water (TOC=2.5 mg/L and surface water (TOC=7.5 mg/L. These solutions were treated with the biocides at a 1:1 molar ratio of C:disinfectant and tested for genotoxicity using the anaphase chromosomal aberration and micronucleus tests in Allium cepa, and the Vicia faba and Tradescantia micronucleus tests. The tests were carried out after different times and with different modes of exposure, and at 1:1 and 1:10 dilutions of disinfected and undisinfected humic acid solutions. A genotoxic effect was found for sodium hypochlorite in all plant tests, at both TOCs considered, while chlorine dioxide gave positive results only with the A.cepa tests. Some positive effects were also detected for PAA (A.cepa and Tradescantia. No relevant differences were found in samples with different TOC values. The significant increase in all genotoxicity end-points induced by all tested disinfectants indicates that a genotoxic potential is exerted even in the presence of organic substances at similar concentrations to those frequently present in drinking water.

  8. Fabrication and Characterization of the US Army Research Laboratory Surface Enhanced Raman Scattering (SERS) Substrates

    Science.gov (United States)

    2017-12-04

    enhancement. The chemical enhancement occurs when there is a charge transfer resonance between the molecule and the metalized surface. These effects can also...various genes, chemical warfare species, bacteria,60,108–114 diagnostic markers, environmental pollutants , glucose monitoring,102,115 and stress...Inspired Materials 5 1.2 US Army-Relevant Applications of SERS-Hazard Detection 7 1.3 Assessing SERS Substrate: ARL/Edgewood Chemical Biological

  9. Implementation of quality control systems in laboratories in Paraguay by the participants of ARCAL LXXVI project

    International Nuclear Information System (INIS)

    Villanueva, Z.

    2004-12-01

    In the Project ARCAL LXXVII, was realized the National Course of Control of Quality of Analytic Laboratories, from 12 to 16 of April in the CNEA, Paraguay, as a result of the one mentioned course was elaborated this project whose purpose is to elaborate the necessary documentation to fulfill the requirements of administration in the Analytic Laboratories to be adapted to the system of quality according to the ISO 17025 [es

  10. Description of the EDF research and development laboratory's radiographic picture processing system

    International Nuclear Information System (INIS)

    Brillault, B.

    1985-01-01

    A digital radiographic picture processing system has been developed at the EDF Research and Development Laboratory to be supplied to EDF radiography experts. We describe it in pointing out the difficulties of radiograph digitization but also the numerous processing possibilities. The final goal of the Laboratory work is to extract the information from industrial radiographs by digital means. Our study is divided into three parts: digitization by a microdensitometer; display, processing and quantization of flaws; and, digital storing. 5 refs

  11. Laboratory Experimental System for Examination of Acoustic Emission Generated by Partial Discharges

    Directory of Open Access Journals (Sweden)

    I. M. Salom

    2013-11-01

    Full Text Available One of the major causes of transformer failures is dielectric breakdown. Partial discharges cause gradual insulation degradation thus partial discharge activity monitoring provides transformer state insight. This paper gives an overview of common methods for partial discharges detection and source location in transformers, with a special reference to the acoustic method as an noninvasive and interference resistant method suitable for application. For laboratory testing a laboratory experimental system for partial discharge diagnostics using acoustic emission measurement was developed.

  12. A Comet Surface Sample Return System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed Phase I investigation will focus on the development of spacecraft systems required to obtain a sample from the nucleus of a comet, hermetically seal the...

  13. System and method for extracting a sample from a surface

    Science.gov (United States)

    Van Berkel, Gary; Covey, Thomas

    2015-06-23

    A system and method is disclosed for extracting a sample from a sample surface. A sample is provided and a sample surface receives the sample which is deposited on the sample surface. A hydrophobic material is applied to the sample surface, and one or more devices are configured to dispense a liquid on the sample, the liquid dissolving the sample to form a dissolved sample material, and the one or more devices are configured to extract the dissolved sample material from the sample surface.

  14. Sikorsky interactive graphics surface design/manufacturing system

    Science.gov (United States)

    Robbins, R.

    1975-01-01

    An interactive graphics system conceived to be used in the design, analysis, and manufacturing of aircraft components with free form surfaces was described. In addition to the basic surface definition and viewing capabilities inherent in such a system, numerous other features are present: surface editing, automated smoothing of control curves, variable milling patch boundary definitions, surface intersection definition and viewing, automatic creation of true offset surfaces, digitizer and drafting machine interfaces, and cutter path optimization. Documented costs and time savings of better than six to one are being realized with this system. The system was written in FORTRAN and GSP for use on IBM 2250 CRT's in conjunction with an IBM 370/158 computer.

  15. Design and installation of a laboratory-scale system for radioactive waste treatment

    International Nuclear Information System (INIS)

    Berger, D.N.; Knox, C.A.; Siemens, D.H.

    1980-05-01

    Described are the mechanical design features and remote installation of a laboratory-scale radiochemical immobilization system which is to provide a means at Pacific Northwest Laboratory of studying effluents generated during solidification of high-level liquid radioactive waste. Detailed are the hot cell, instrumentation, two 4-in. and 12-in. service racks, the immobilization system modules - waste feed, spray calciner unit, and effluent - and a gamma emission monitor system for viewing calcine powder buildup in the spray calciner/in-can melter

  16. Statement of Work Electrical Energy Storage System Installation at Sandia National Laboratories.

    Energy Technology Data Exchange (ETDEWEB)

    Schenkman, Benjamin L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-03-01

    Sandia is seeking to procure a 1 MWh energy storage system. It will be installed at the existing Energy Storage Test Pad, which is located at Sandia National Laboratories in Albuquerque, New Mexico. This energy storage system will be a daily operational system, but will also be used as a tool in our Research and development work. The system will be part of a showcase of Sandia distributed energy technologies viewed by many distinguished delegates.

  17. Progress in Harmonizing Tiered HIV Laboratory Systems: Challenges and Opportunities in 8 African Countries

    Science.gov (United States)

    Williams, Jason; Umaru, Farouk; Edgil, Dianna; Kuritsky, Joel

    2016-01-01

    ABSTRACT In 2014, the Joint United Nations Programme on HIV/AIDS released its 90-90-90 targets, which make laboratory diagnostics a cornerstone for measuring efforts toward the epidemic control of HIV. A data-driven laboratory harmonization and standardization approach is one way to create efficiencies and ensure optimal laboratory procurements. Following the 2008 “Maputo Declaration on Strengthening of Laboratory Systems”—a call for government leadership in harmonizing tiered laboratory networks and standardizing testing services—several national ministries of health requested that the United States Government and in-country partners help implement the recommendations by facilitating laboratory harmonization and standardization workshops, with a primary focus on improving HIV laboratory service delivery. Between 2007 and 2015, harmonization and standardization workshops were held in 8 African countries. This article reviews progress in the harmonization of laboratory systems in these 8 countries. We examined agreed-upon instrument lists established at the workshops and compared them against instrument data from laboratory quantification exercises over time. We used this measure as an indicator of adherence to national procurement policies. We found high levels of diversity across laboratories’ diagnostic instruments, equipment, and services. This diversity contributes to different levels of compliance with expected service delivery standards. We believe the following challenges to be the most important to address: (1) lack of adherence to procurement policies, (2) absence or limited influence of a coordinating body to fully implement harmonization proposals, and (3) misalignment of laboratory policies with minimum packages of care and with national HIV care and treatment guidelines. Overall, the effort to implement the recommendations from the Maputo Declaration has had mixed success and is a work in progress. Program managers should continue efforts to

  18. Strengthening systems for communicable disease surveillance: creating a laboratory network in Rwanda

    Directory of Open Access Journals (Sweden)

    Ndihokubwayo Jean B

    2011-06-01

    Full Text Available Abstract Background The recent emergence of a novel strain of influenza virus with pandemic potential underscores the need for quality surveillance and laboratory services to contribute to the timely detection and confirmation of public health threats. To provide a framework for strengthening disease surveillance and response capacities in African countries, the World Health Organization Regional Headquarters for Africa (AFRO developed Integrated Disease Surveillance and Response (IDSR aimed at improving national surveillance and laboratory systems. IDSR emphasizes the linkage of information provided by public health laboratories to the selection of relevant, appropriate and effective public health responses to disease outbreaks. Methods We reviewed the development of Rwanda's National Reference Laboratory (NRL to understand essential structures involved in creating a national public health laboratory network. We reviewed documents describing the NRL's organization and record of test results, conducted site visits, and interviewed health staff in the Ministry of Health and in partner agencies. Findings were developed by organizing thematic categories and grouping examples within them. We purposefully sought to identify success factors as well as challenges inherent in developing a national public health laboratory system. Results Among the identified success factors were: a structured governing framework for public health surveillance; political commitment to promote leadership for stronger laboratory capacities in Rwanda; defined roles and responsibilities for each level; coordinated approaches between technical and funding partners; collaboration with external laboratories; and use of performance results in advocacy with national stakeholders. Major challenges involved general infrastructure, human resources, and budgetary constraints. Conclusions Rwanda's experience with collaborative partnerships contributed to creation of a functional

  19. Laboratory QA/QC improvements for small drinking water systems at Savannah River Site

    Energy Technology Data Exchange (ETDEWEB)

    Turner, R.D.

    1995-12-01

    The Savannah River Site (SRS), a 310 square mile facility located near Aiken, S.C., is operated by Westinghouse Savannah River Company for the US Department of Energy. SRS has 28 separate drinking water systems with average daily demands ranging from 0.0002 to 0.5 MGD. All systems utilize treated groundwater. Until recently, the water laboratories for each system operated independently. As a result, equipment, reagents, chemicals, procedures, personnel, and quality control practices differed from location to location. Due to this inconsistency, and a lack of extensive laboratory OA/QC practices at some locations, SRS auditors were not confident in the accuracy of daily water quality analyses results. The Site`s Water Services Department addressed these concerns by developing and implementing a practical laboratory QA/QC program. Basic changes were made which can be readily adopted by most small drinking water systems. Key features of the program include: Standardized and upgraded laboratory instrumentation and equipment; standardized analytical procedures based on vendor manuals and site requirements; periodic accuracy checks for all instrumentation; creation of a centralized laboratory to perform metals digestions and chlorine colorimeter accuracy checks; off-site and on-site operator training; proper storage, inventory and shelf life monitoring for reagents and chemicals. This program has enhanced the credibility and accuracy of SRS drinking water system analyses results.

  20. On the atmospheric chemistry of NO2 - O3 systems : a laboratory study

    NARCIS (Netherlands)

    Verhees, P.W.C.

    1986-01-01

    In this dissertation a laboratory study dealing with the atmospheric chemistry of NO 2 -O 3 systems is described. Knowledge of this system is relevant for a better

  1. Model-based fuzzy control solutions for a laboratory Antilock Braking System

    DEFF Research Database (Denmark)

    Precup, Radu-Emil; Spataru, Sergiu; Rǎdac, Mircea-Bogdan

    2010-01-01

    This paper gives two original model-based fuzzy control solutions dedicated to the longitudinal slip control of Antilock Braking System laboratory equipment. The parallel distributed compensation leads to linear matrix inequalities which guarantee the global stability of the fuzzy control systems....... Real-time experimental results validate the new fuzzy control solutions....

  2. Assessment of laboratory logistics management information system practice for HIV/AIDS and tuberculosis laboratory commodities in selected public health facilities in Addis Ababa, Ethiopia.

    Science.gov (United States)

    Desale, Adino; Taye, Bineyam; Belay, Getachew; Nigatu, Alemayehu

    2013-01-01

    Logistics management information system for health commodities remained poorly implemented in most of developing countries. To assess the status of laboratory logistics management information system for HIV/AIDS and tuberculosis laboratory commodities in public health facilities in Addis Ababa. A cross-sectional descriptive study was conducted from September 2010-January 2011 at selected public health facilities. A stratified random sampling method was used to include a total of 43 facilities which, were investigated through quantitative methods using structured questionnaires interviews. Focus group discussion with the designated supply chain managers and key informant interviews were conducted for the qualitative method. There exists a well-designed logistics system for laboratory commodities with trained pharmacy personnel, distributed standard LMIS formats and established inventory control procedures. However, majority of laboratory professionals were not trained in LMIS. Majority of the facilities (60.5%) were stocked out for at least one ART monitoring and TB laboratory reagents and the highest stock out rate was for chemistry reagents. Expired ART monitoring laboratory commodities were found in 25 (73.5%) of facilities. Fifty percent (50%) of the assessed hospitals and 54% of health centers were currently using stock/bin cards for all HIV/AIDS and TB laboratory commodities in main pharmacy store, among these only 25% and 20.8% of them were updated with accurate information matching with the physical count done at the time of visit for hospitals and health centers respectively. Even though there exists a well designed laboratory LMIS, keeping quality stock/bin cards and LMIS reports were very low. Key ART monitoring laboratory commodities were stock out at many facilities at the day of visit and during the past six months. Based on findings, training of laboratory personnel's managing laboratory commodities and keeping accurate inventory control procedures

  3. Medical expert systems developed in j.MD, a Java based expert system shell: application in clinical laboratories.

    Science.gov (United States)

    Van Hoof, Viviane; Wormek, Arno; Schleutermann, Sylvia; Schumacher, Theo; Lothaire, Olivier; Trendelenburg, Christian

    2004-01-01

    Growing complexity of diagnostic tests, combined with increased workload, stringent laboratory accreditation demands, continuous shortening of turn-around-time and budget restrictions have forced laboratories to automate most of their iterative tasks. Introduction of artificial intelligence by means of expert systems has gained an important place in this automation process. Different parts of clinical laboratory activity can benefit from their implementation and the present project deals with one aspect, namely the clinical interpretation of diagnostic tests. This paper describes how j.MD, a new Java based expert system shell, was used to reprogram the expert system for interpretation of amylase isoenzyme patterns that has been in use for many years in our laboratory, and that was originally programmed in Pro.MD, a Prolog based expert system shell. One of the most important advantages of the j.MD system is its bidirectional link with the laboratory information system. This project shows how expert systems for the interpretation of complex diagnostic tests that demand specific expertise can become an integrated part of the automated clinical chemistry lab.

  4. Low energy ion beam systems for surface analytical and structural studies

    International Nuclear Information System (INIS)

    Nelson, G.C.

    1980-01-01

    This paper reviews the use of low energy ion beam systems for surface analytical and structural studies. Areas where analytical methods which utilize ion beams can provide a unique insight into materials problems are discussed. The design criteria of ion beam systems for performing materials studies are described and the systems now being used by a number of laboratories are reviewed. Finally, several specific problems are described where the solution was provided at least in part by information provided by low energy ion analysis techniques

  5. In situ surface-enhanced raman spectroelectrochemical analysis system with a hemin modified nanostructured gold surface

    NARCIS (Netherlands)

    Yuan, Tao; Le Thi Ngoc, Loan; van Nieuwkasteele, Jan William; Odijk, Mathieu; van den Berg, Albert; Permentier, Hjalmar; Bischoff, Rainer; Carlen, Edwin

    2015-01-01

    An integrated surface-enhanced Raman scattering (SERS) spectroelectrochemical (SEC) analysis system is presented that combines a small volume microfluidic sample chamber (<100 mu L) with a compact three-electrode configuration for in situ surface-enhanced Raman spectroelectrochemistry. The SEC

  6. A laboratory investigation of mixing dynamics between biofuels and surface waters

    Science.gov (United States)

    Wang, Xiaoxiang; Cotel, Aline

    2017-11-01

    Recently, production and usage of ethanol-blend fuels or biofuels have increased dramatically along with increasing risk of spilling into surface waters. Lack of understanding of the environmental impacts and absence of standard clean-up procedures make it crucial to study the mixing behavior between biofuels and water. Biofuels are represented by a solution of ethanol and glycol. A Plexiglas tank in conjunction with a wave generator is used to simulate the mixing of surface waters and biofuels under different natural conditions. In our previous experiments, two distinct mixing regimes were observed. One regime was driven by turbulence and the other by interfacial instabilities. However, under more realistic situations, without wind driven waves, only the first mixing regime was found. After one minute of rapid turbulent mixing, biofuels and water were fully mixed and no interface was formed. During the mixing process, chemical reactions happened simultaneously and influenced mixing dynamics. Current experiments are investigating the effect of waves on the mixing dynamics. Support from NSF CBET 1335878.

  7. Clinical significance of laboratory errors in patients with systemic lupus erythematosus

    Directory of Open Access Journals (Sweden)

    N.G. Klyukvina

    2014-01-01

    Full Text Available Laboratory examination is an integral part of managing patients with systemic lupus erythematosus (SLE. A number of laboratory tests need to be conducted to verify the diagnosis; some indicators attest to the development of a concomitant pathology (development of comorbid conditions and therapeutic aggravation. The monitoring of individual laboratory tests makes it possible to assess the effectiveness of therapy or indicates that it needs to be enhanced in some cases. Furthermore, some parameters are considered to be prognostic factors of treatment outcome. The article reports on the range and frequency of laboratory errors in SLE patients. The role of laboratory tests in diagnosis and assessment of disease prognosis is discussed. The relationship between clinical and laboratory manifestations and the mechanisms for preventing laboratory errors are studied. The international guidelines for monitoring SLE patients are presented. Proper range of examination of SLE patients and interpretation of the results ensures timely diagnosis (sometimes at the early stage and allows one to avoid a hyperdiagnosis, to timely prescribe adequate therapy, and prevent its complications. 

  8. Surface free energy for systems with integrable boundary conditions

    International Nuclear Information System (INIS)

    Goehmann, Frank; Bortz, Michael; Frahm, Holger

    2005-01-01

    The surface free energy is the difference between the free energies for a system with open boundary conditions and the same system with periodic boundary conditions. We use the quantum transfer matrix formalism to express the surface free energy in the thermodynamic limit of systems with integrable boundary conditions as a matrix element of certain projection operators. Specializing to the XXZ spin-1/2 chain we introduce a novel 'finite temperature boundary operator' which characterizes the thermodynamical properties of surfaces related to integrable boundary conditions

  9. Pre-Ebola virus disease laboratory system and related challenges in Liberia

    Directory of Open Access Journals (Sweden)

    Stephen B. Kennedy

    2016-10-01

    Full Text Available Prior to the Ebola virus disease outbreak in Liberia, the laboratory system was duplicativefragmented and minimally coordinated. The National Reference Laboratory was conceptualisedto address the existing challenges by promoting the implementation of effective and sustainablelaboratory services in Liberia. However, in a resource-limited environment such as Liberiaprogress regarding the rebuilding of the health system can be relatively slow, while efforts tosustain the transient gains remain a key challenge for the Ministry of Health. In this paper, wedescribe the pre-Ebola virus disease laboratory system in Liberia and its prevailing efforts toaddress future emerging infectious diseases, as well as current Infectious diseases, all of whichare exacerbated by poverty. We conclude that laboratory and diagnostic services in Liberiahave encountered numerous challenges regarding its efforts to strengthen the healthcaredelivery system. These challenges include limited trained human resource capacity, inadequateinfrastructure, and a lack of coordination. As with most countries in sub-Saharan Africa, whencomparing urban and rural settings, diagnostic and clinical services are generally skewedtoward urban health facilities and private, faith-based health facilities. We recommend thatstructured policy be directed at these challenges for national institutions to develop guidelinesto improve, strengthen and sustain diagnostic and curative laboratory services to effectivelyaddress current infectious diseases and prepare for future emerging and re-emerging infectiousdiseases.

  10. Developing Learning Tool of Control System Engineering Using Matrix Laboratory Software Oriented on Industrial Needs

    Science.gov (United States)

    Isnur Haryudo, Subuh; Imam Agung, Achmad; Firmansyah, Rifqi

    2018-04-01

    The purpose of this research is to develop learning media of control technique using Matrix Laboratory software with industry requirement approach. Learning media serves as a tool for creating a better and effective teaching and learning situation because it can accelerate the learning process in order to enhance the quality of learning. Control Techniques using Matrix Laboratory software can enlarge the interest and attention of students, with real experience and can grow independent attitude. This research design refers to the use of research and development (R & D) methods that have been modified by multi-disciplinary team-based researchers. This research used Computer based learning method consisting of computer and Matrix Laboratory software which was integrated with props. Matrix Laboratory has the ability to visualize the theory and analysis of the Control System which is an integration of computing, visualization and programming which is easy to use. The result of this instructional media development is to use mathematical equations using Matrix Laboratory software on control system application with DC motor plant and PID (Proportional-Integral-Derivative). Considering that manufacturing in the field of Distributed Control systems (DCSs), Programmable Controllers (PLCs), and Microcontrollers (MCUs) use PID systems in production processes are widely used in industry.

  11. Leaf LIMS: A Flexible Laboratory Information Management System with a Synthetic Biology Focus.

    Science.gov (United States)

    Craig, Thomas; Holland, Richard; D'Amore, Rosalinda; Johnson, James R; McCue, Hannah V; West, Anthony; Zulkower, Valentin; Tekotte, Hille; Cai, Yizhi; Swan, Daniel; Davey, Robert P; Hertz-Fowler, Christiane; Hall, Anthony; Caddick, Mark

    2017-12-15

    This paper presents Leaf LIMS, a flexible laboratory information management system (LIMS) designed to address the complexity of synthetic biology workflows. At the project's inception there was a lack of a LIMS designed specifically to address synthetic biology processes, with most systems focused on either next generation sequencing or biobanks and clinical sample handling. Leaf LIMS implements integrated project, item, and laboratory stock tracking, offering complete sample and construct genealogy, materials and lot tracking, and modular assay data capture. Hence, it enables highly configurable task-based workflows and supports data capture from project inception to completion. As such, in addition to it supporting synthetic biology it is ideal for many laboratory environments with multiple projects and users. The system is deployed as a web application through Docker and is provided under a permissive MIT license. It is freely available for download at https://leaflims.github.io .

  12. Factors Influencing Laboratory Information System Effectiveness Through Strategic Planning in Shiraz Teaching Hospitals.

    Science.gov (United States)

    Bahador, Fateme; Sharifian, Roxana; Farhadi, Payam; Jafari, Abdosaleh; Nematolahi, Mohtram; Shokrpour, Nasrin

    This study aimed to develop and test a research model that examined 7effective factors on the effectiveness of laboratory information system (LIS) through strategic planning. This research was carried out on total laboratory staff, information technology staff, and laboratory managers in Shiraz (a city in the south of Iran) teaching hospitals by structural equation modeling approach in 2015. The results revealed that there was no significant positive relationship between decisions based on cost-benefit analysis and LIS functionality with LIS effectiveness, but there was a significant positive relationship between other factors and LIS effectiveness. As expected, high levels of strategic information system planning result in increasing LIS effectiveness. The results also showed that the relationship between cost-benefit analysis, LIS functionality, end-user involvement, and information technology-business alignment with strategic information system planning was significant and positive.

  13. Developing an Affordable and Portable Control Systems Laboratory Kit with a Raspberry Pi

    Directory of Open Access Journals (Sweden)

    Rebecca M. Reck

    2016-07-01

    Full Text Available Instructional laboratories are common in engineering programs. Instructional laboratories should evolve with technology and support the changes in higher education, like the increased popularity of online courses. In this study, an affordable and portable laboratory kit was designed to replace the expensive on-campus equipment for two control systems courses. The complete kit costs under $135 and weighs under 0.68 kilograms. It is comprised of off-the-shelf components (e.g., Raspberry Pi, DC motor and 3D printed parts. The kit has two different configurations. The first (base configuration is a DC motor system with a position and speed sensor. The second configuration adds a Furuta inverted pendulum attachment with another position sensor. These configurations replicate most of the student learning outcomes for the two control systems courses for which they were designed.

  14. Iron oxides stimulate microbial monochlorobenzene in situ transformation in constructed wetlands and laboratory systems

    International Nuclear Information System (INIS)

    Schmidt, Marie; Wolfram, Diana; Birkigt, Jan; Ahlheim, Jörg; Paschke, Heidrun; Richnow, Hans-Hermann; Nijenhuis, Ivonne

    2014-01-01

    Natural wetlands are transition zones between anoxic ground and oxic surface water which may enhance the (bio)transformation potential for recalcitrant chloro-organic contaminants due to the unique geochemical conditions and gradients. Monochlorobenzene (MCB) is a frequently detected groundwater contaminant which is toxic and was thought to be persistent under anoxic conditions. Furthermore, to date, no degradation pathways for anoxic MCB removal have been proven in the field. Hence, it is important to investigate MCB biodegradation in the environment, as groundwater is an important drinking water source in many European countries. Therefore, two pilot-scale horizontal subsurface-flow constructed wetlands, planted and unplanted, were used to investigate the processes in situ contributing to the biotransformation of MCB in these gradient systems. The wetlands were fed with anoxic MCB-contaminated groundwater from a nearby aquifer in Bitterfeld, Germany. An overall MCB removal was observed in both wetlands, whereas just 10% of the original MCB inflow concentration was detected in the ponds. In particular in the gravel bed of the planted wetland, MCB removal was highest in summer season with 73 ± 9% compared to the unplanted one with 40 ± 5%. Whereas the MCB concentrations rapidly decreased in the transition zone of unplanted gravel to the pond, a significant MCB removal was already determined in the anoxic gravel bed of the planted system. The investigation of hydro-geochemical parameters revealed that iron and sulphate reduction were relevant redox processes in both wetlands. In parallel, the addition of ferric iron or nitrate stimulated the mineralisation of MCB in laboratory microcosms with anoxic groundwater from the same source, indicating that the potential for anaerobic microbial degradation of MCB is present at the field site. - Highlights: • MCB removal in anoxic gravel bed of a planted and an unplanted constructed wetland was accompanied by iron

  15. Iron oxides stimulate microbial monochlorobenzene in situ transformation in constructed wetlands and laboratory systems

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Marie; Wolfram, Diana; Birkigt, Jan [Department of Isotope Biogeochemistry, Helmholtz Centre for Environmental Research — UFZ, Permoserstrasse 15, 04318 Leipzig (Germany); Ahlheim, Jörg [Department of Groundwater Remediation, Helmholtz Centre for Environmental Research — UFZ, Permoserstrasse 15, 04318 Leipzig (Germany); Paschke, Heidrun [Department of Analytical Chemistry, Helmholtz Centre for Environmental Research — UFZ, Permoserstrasse 15, 04318 Leipzig (Germany); Richnow, Hans-Hermann [Department of Isotope Biogeochemistry, Helmholtz Centre for Environmental Research — UFZ, Permoserstrasse 15, 04318 Leipzig (Germany); Nijenhuis, Ivonne, E-mail: ivonne.nijenhuis@ufz.de [Department of Isotope Biogeochemistry, Helmholtz Centre for Environmental Research — UFZ, Permoserstrasse 15, 04318 Leipzig (Germany)

    2014-02-01

    Natural wetlands are transition zones between anoxic ground and oxic surface water which may enhance the (bio)transformation potential for recalcitrant chloro-organic contaminants due to the unique geochemical conditions and gradients. Monochlorobenzene (MCB) is a frequently detected groundwater contaminant which is toxic and was thought to be persistent under anoxic conditions. Furthermore, to date, no degradation pathways for anoxic MCB removal have been proven in the field. Hence, it is important to investigate MCB biodegradation in the environment, as groundwater is an important drinking water source in many European countries. Therefore, two pilot-scale horizontal subsurface-flow constructed wetlands, planted and unplanted, were used to investigate the processes in situ contributing to the biotransformation of MCB in these gradient systems. The wetlands were fed with anoxic MCB-contaminated groundwater from a nearby aquifer in Bitterfeld, Germany. An overall MCB removal was observed in both wetlands, whereas just 10% of the original MCB inflow concentration was detected in the ponds. In particular in the gravel bed of the planted wetland, MCB removal was highest in summer season with 73 ± 9% compared to the unplanted one with 40 ± 5%. Whereas the MCB concentrations rapidly decreased in the transition zone of unplanted gravel to the pond, a significant MCB removal was already determined in the anoxic gravel bed of the planted system. The investigation of hydro-geochemical parameters revealed that iron and sulphate reduction were relevant redox processes in both wetlands. In parallel, the addition of ferric iron or nitrate stimulated the mineralisation of MCB in laboratory microcosms with anoxic groundwater from the same source, indicating that the potential for anaerobic microbial degradation of MCB is present at the field site. - Highlights: • MCB removal in anoxic gravel bed of a planted and an unplanted constructed wetland was accompanied by iron

  16. Laboratory studies of spectroscopic markers for the characterization of surface erosion by plasmas

    International Nuclear Information System (INIS)

    Manos, D.M.; Bennett, T.; Herzer, M.; Schwarzmann, J.

    1992-01-01

    The erosion rates in portions of fusion plasma devices like the ITER tokamak are sufficiently high that nearly real-time information on cumulative removal is needed for control and machine safety. We are developing a digitally--encoded scheme to indicate the depth of erosion at numerous poloidal and toroidal locations around ITER. The scheme uses materials embedded in the walls and divertors, which, when uncovered, present remotely detectable signals. This paper reports laboratory experiments on prototype markers consisting of combinations of up to 5 elements (Au,Pd,Ag,In,Ga) along with Au,Pt, and Ta pure metals. The markers were bonded to 4-D carbon-carbon composite of the type proposed for use in the ITER first wall, and placed in the lower-hybrid-driven plasma of the atomic beam facility at PPL. The paper describes this device Light emission was characterized using a 1 meter Czerny-Turner vacuum ultraviolet monochromator. The samples were characterized both before and after plasma exposure by Auger spectroscopy. We report the time-dependent behavior of the spectra of the visible and ultraviolet light emitted by the plasma when the markers are uncovered by the erosion showing emission lines of the marker elements which are easily distinguished from the background plasma lines. The dependence of the light intensity on bias voltage is compared to the known sputtering yields of the elements. The optical detection method allows exploration of the threshold dependence of these multi-element targets. An exponential dependence of yield above threshold was observed for all of the elements studied

  17. An overview of Quality Management System implementation in a research laboratory

    Science.gov (United States)

    Molinéro-Demilly, Valérie; Charki, Abdérafi; Jeoffrion, Christine; Lyonnet, Barbara; O'Brien, Steve; Martin, Luc

    2018-02-01

    The aim of this paper is to show the advantages of implementing a Quality Management System (QMS) in a research laboratory in order to improve the management of risks specific to research programmes and to increase the reliability of results. This paper also presents experience gained from feedback following the implementation of the Quality process in a research laboratory at INRA, the French National Institute for Agronomic Research and details the various challenges encountered and solutions proposed to help achieve smoother adoption of a QMS process. The 7Ms (Management, Measurement, Manpower, Methods, Materials, Machinery, Mother-nature) methodology based on the Ishikawa `Fishbone' diagram is used to show the effectiveness of the actions considered by a QMS, which involve both the organization and the activities of the laboratory. Practical examples illustrate the benefits and improvements observed in the laboratory.

  18. Assessing the outcome of Strengthening Laboratory Management Towards Accreditation (SLMTA) on laboratory quality management system in city government of Addis Ababa, Ethiopia.

    Science.gov (United States)

    Sisay, Abay; Mindaye, Tedla; Tesfaye, Abrham; Abera, Eyob; Desale, Adino

    2015-01-01

    Strengthening Laboratory Management Toward Accreditation (SLMTA) is a competency-based management training programme designed to bring about immediate and measurable laboratory improvement. The aim of this study is to assess the outcome of SLMTA on laboratory quality management system in Addis Ababa, Ethiopia. The study used an Institutional based cross sectional study design that employed a secondary and primary data collection approach on the participated institution of medical laboratory in SLMTA. The study was conducted in Addis Ababa city government and the data was collected from February 'April 2014 and data was entered in to EPI-data version 3.1 and was analyzed by SPSS version 20. The assessment finding indicate that there was a significant improvement in average scores (141.4; range of 65-196, 95%CI=86.275-115.5, p=0.000) at final with 3 laboratories become 3 star, 6 laboratories were at 2 star, 11 were 1 star. Laboratory facilities respondents which thought getting adequate and timely manner mentorship were found 2.5 times more likely to get good success in the final score(AOR=2.501, 95% CI=1.109-4.602) than which did not get it. At the end of SLMTA implementation,3 laboratories score 3 star, 6 laboratories were at 2 star, 11 were at 1 star. The most important contributing factor for not scoring star in the final outcome of SLMTA were not conducting their customer satisfaction survey, poor staff motivation, and lack of regular equipment service maintenance. Mentorship, onsite and offsite coaching and training activities had shown a great improvement on laboratory quality management system in most laboratories.

  19. Waste-surface mapping of the Fernald K-65 silos using a structured light measurement system

    International Nuclear Information System (INIS)

    Burks, B.L.; DePiero, F.W.; Dinkins, M.A.; Rowe, J.C.; Selleck, C.B.; Jacoboski, D.L.

    1992-10-01

    A remotely operated surface-mapping measurement system was developed by the Robotics ampersand Process Systems Division at Oak Ridge National Laboratory for use in the K-65 waste-storage silos at Fernald, Ohio. The mapping system used three infrared line-generating laser diodes as illumination sources and three high-resolution, low-lux, calibrated, black-and-white, charge-coupled-device video cameras as receivers. These components were combined to form structured light source range and direction sensors with six different possible emitter-receiver pairs. A technology demonstration and predeployment tests were performed at Fernald using the empty Silo 4 into which was placed rectangular objects of known dimensions. These objects were scanned by the structured light sources to demonstrate functionality and verify that the system was giving sufficiently accurate range data in three dimensions. The structured light sources were deployed in Silos 1 and 2 to scan the waste surfaces. The resulting data were merged to create three-dimensional maps of those surfaces. A bentonite clay cap was placed over the waste surfaces and surface maps were obtained. The change in surface height before and after bentonite addition was utilized as a measure of clay cap thickness

  20. Modification and testing of the Sandia Laboratories Livermore tritium decontamination systems

    International Nuclear Information System (INIS)

    Gildea, P.D.; Birnbaum, H.G.; Wall, W.R.

    1979-01-01

    Sandia Laboratories, Livermore, has put into operation a new facility, the Tritium Research Laboratory. The laboratory incorporates containment and cleanup facilities such that any tritium accidentally released is captured rather than vented to the atmosphere. This containment is achieved with hermetically sealed glove boxes that are connected on demand by manifolds to two central decontamination systems called the Gas Purification System (GPS) and the Vacuum Effluent Recovery System (VERS). The primary function of the GPS is to remove tritium and tritiated water vapor from the glove box atmosphere. The primary function of the VERS is to decontaminate the gas exhausted from the glove box pressure control systems and vacuum pumps in the building before venting the gas to the stack. Both of these systems are designed to remove tritium to the few parts per billion range. Acceptance tests at the manufacturer's plant and preoperational testing at Livermore demonstrated that the systems met their design specifications. After preoperational testing the Gas Purification System was modified to enhance the safety of maintanance operations. Both the Gas Purification System and the Vacuum Effluent Recovery System were performance tested with tritium. Results show that concentration reduction factors (ratio of inlet to exhaust concentrations) much in excess of 1000 per pass have been achieved for both systems at inlet concentrations of 1 ppM or less

  1. Laboratory tests of overpressure differential systems for smoke protection of lobbies

    Science.gov (United States)

    Szałański, Paweł; Misiński, Jacek

    2017-11-01

    Paper presents the methodology of laboratory tests for ventilation overpressure differential systems for smoke protection of lobbies. Research area consists of two spaces representing the lobby and the area under fire equipped with proper ventilation installation. This allows testing of overpressure differential systems for smoke protection of lobbies. Moreover, piece of laboratory tests results for two selected smoke protection systems for lobbies are presented. First one is standard system with constantly opened transfer-damper mounted between lobby and area under fire. Second one - system with so called "electronic transfer" based on two dampers (supplying air to a lobby and to unprotected area alternatively). Opening and closing both dampers is electronically controlled. Changes of pressure difference between lobby and fire affected area during closing and opening doors between those spaces is presented. Conclusions, concerning the possibility of meeting the time period criteria of pressure difference stabilization required by standards, are presented and discussed for both systems.

  2. Laboratory investigation and direct numerical simulation of wind effect on steep surface waves

    Science.gov (United States)

    Troitskaya, Yuliya; Sergeev, Daniil; Druzhinin, Oleg; Ermakova, Olga

    2015-04-01

    The small scale ocean-atmosphere interaction at the water-air interface is one of the most important factors determining the processes of heat, mass, and energy exchange in the boundary layers of both geospheres. Another important aspect of the air-sea interaction is excitation of surface waves. One of the most debated open questions of wave modeling is concerned with the wind input in the wave field, especially for the case of steep and breaking waves. Two physical mechanisms are suggested to describe the excitation of finite amplitude waves. The first one is based on the treatment of the wind-wave interaction in quasi-linear approximation in the frameworks of semi-empirical models of turbulence of the low atmospheric boundary layer. An alternative mechanism is associated with separation of wind flow at the crests of the surface waves. The "separating" and "non-separating" mechanisms of wave generation lead to different dependences of the wind growth rate on the wave steepness: the latter predicts a decrease in the increment with wave steepness, and the former - an increase. In this paper the mechanism of the wind-wave interaction is investigated basing on physical and numerical experiments. In the physical experiment, turbulent airflow over waves was studied using the video-PIV method, based on the application of high-speed video photography. Alternatively to the classical PIV technique this approach provides the statistical ensembles of realizations of instantaneous velocity fields. Experiments were performed in a round wind-wave channel at Institute of Applied Physics, Russian Academy of Sciences. A fan generated the airflow with the centerline velocity 4 m/s. The surface waves were generated by a programmed wave-maker at the frequency of 2.5 Hz with the amplitudes of 0.65 cm, 1.4 cm, and 2 cm. The working area (27.4 × 10.7 cm2) was at a distance of 3 m from the fan. To perform the measurements of the instantaneous velocity fields, spherical polyamide

  3. SOFTICE: Facilitating both Adoption of Linux Undergraduate Operating Systems Laboratories and Students' Immersion in Kernel Code

    Directory of Open Access Journals (Sweden)

    Alessio Gaspar

    2007-06-01

    Full Text Available This paper discusses how Linux clustering and virtual machine technologies can improve undergraduate students' hands-on experience in operating systems laboratories. Like similar projects, SOFTICE relies on User Mode Linux (UML to provide students with privileged access to a Linux system without creating security breaches on the hosting network. We extend such approaches in two aspects. First, we propose to facilitate adoption of Linux-based laboratories by using a load-balancing cluster made of recycled classroom PCs to remotely serve access to virtual machines. Secondly, we propose a new approach for students to interact with the kernel code.

  4. Argonne National Laboratory's photo-oxidation organic mixed waste treatment system - installation and startup testing

    International Nuclear Information System (INIS)

    Shearer, T.L.; Nelson, R.A.; Torres, T.; Conner, C.; Wygmans, D.

    1997-01-01

    This paper describes the installation and startup testing of the Argonne National Laboratory (ANL-E) Photo-Oxidation Organic Mixed Waste Treatment System. This system will treat organic mixed (i.e., radioactive and hazardous) waste by oxidizing the organics to carbon dioxide and inorganic salts in an aqueous media. The residue will be treated in the existing radwaste evaporators. The system is installed in the Waste Management Facility at the ANL-E site in Argonne, Illinois. 1 fig

  5. APPLICATION OF A PLC TO A LABORATORY COMPRESSOR WORKSHOP CONTROL SYSTEM

    Directory of Open Access Journals (Sweden)

    Wojciech GÓRA

    2016-06-01

    Full Text Available In this paper a control system of air compressors in a university laboratory is presented. The control system, which is built using the Astraada RCC972 and the GE 90-20 drivers, is an extension of the two states’ inputs and outputs of Astraada. To visualize the work stand, the PC computer class and the Proficy Machine Edition (ME View software were applied. Selected results from the tests of the built control system are presented.

  6. IMPLEMENTATION OF DIGITAL LEARNING USING INTERACTIVE MULTIMEDIA IN EXCRETORY SYSTEM WITH VIRTUAL LABORATORY

    OpenAIRE

    Heru Setiawan; Wiwi Isnaeni; F. Putut Martin Herry Budijantoro; Aditya Marianti

    2015-01-01

    The aim of this study are (1) Developing an interactive multimedia with virtual laboratory in excretory system for senior high school students (2) determine the eligibility of digital multimedia of excretory system (3) determine the effectivity of digital learning using interactive multimedia to improve student’s achievement and student activities of excretory system. This research was conducted in senior high school in Indonesia at SMA 1 Jepon, Blora for 2 month. The research approach using ...

  7. Quality system of the Chemical Analysis Laboratory to fulfill the requirements with Certification Organizations

    International Nuclear Information System (INIS)

    Merlo S, L.; Rodriguez L, R.; Cota S, G.

    1996-01-01

    In the present work was described the Quality System established in the Chemical Analysis Department to fulfill with the Organization requirements, personnel, measurement equipment, calibration, working procedures, etc. to get official acknowledgment by the National Assurance System for Testing laboratories, dependent of the General Standards Direction. There are described the available resources, the performance and control of each of one principal points of the system. (Author)

  8. Research Applications and Capabilities of the NASA/Army Rotorcraft Aircrew Systems Concepts Airborne Laboratory (RASCAL)

    Science.gov (United States)

    Aiken, Edwin W.; Jacobsen, Robert A.; Hindson, William S.

    1996-01-01

    The Rotorcraft Aircrew Systems Concepts Airborne Laboratory (RASCAL) is a UH-60 Black Hawk helicopter that is being modified by NASA and the US Army for flight systems research. The principal systems that are being installed in the aircraft are a Helmet-Mounted Display (HMD) and associated imaging systems, and a programmable full-authority Research Flight Control System (RFCS). In addition, comprehensive instrumentation of both the rigid body of the helicopter and the rotor system is provided. This paper describes the design features of this modern rotorcraft in-flight simulation facility and their current state of development. A brief description of initial research applications is included.

  9. Surface-Mount Rotor Motion Sensing System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — A surface-mounted instrumentation system for measuring rotor blade motions on rotorcraft, for use both in flight and in wind tunnel testing, is proposed for...

  10. Flexible and Safe Control of Mobile Surface Systems, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The primary innovation of this work is a novel Petri net based approach for safe and flexible control of highly capable mobile surface systems, such as long-duration...

  11. Flexible and Safe Control of Mobile Surface Systems, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The primary innovation of this work is a novel approach for flexible and safe control of highly capable mobile surface systems, such as long-duration science rovers,...

  12. A Surface-Mounted Rotor State Sensing System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — A surface-mounted instrumentation system for measuring rotor blade motions on rotorcraft, for use both in flight and in wind tunnel testing, is proposed for...

  13. Sistema laboratorial de fracionamento de carboidratos de concentrados energéticos = Laboratorial system of carbohydrate fractions of energetic concentrate

    Directory of Open Access Journals (Sweden)

    Raquel Franco de Lima

    2006-04-01

    Full Text Available O objetivo deste estudo foi avaliar um sistema laboratorial de fracionamento para carboidratos para identificar e quantificar as frações que compõem esse nutriente em grãos e subprodutos. Foram determinadas as frações: açúcares simples (AS pelo método colorimétrico fenol-sulfúrico; amido disponível (AD e amido resistente (AR por digestões enzimáticas; fibra total (FT pelo método enzímico-gravimétrico; fibra em detergente neutro (FDN e fibra solúvel (FS, estimada pela diferença FT-FDN dos grãos de milho e sorgo, polpa de citrus, farelo de trigo, triguilho e farelo de arroz integral. Os coeficientes de variação para as frações AS, AD, AR, FT e FDN variaram de 4,81% a 19,17%; 4,58% a 15,03%; 2,42% a 9,91%; 1,23% a 8,23% e 1,16% a 8,42%, respectivamente, caracterizando uma boa repetibilidade das técnicas adotadas. O fracionamento identificou os principais grupos de carboidratos que compõem os alimentos e pode servir de referência para trabalhos futuros.The aim of this work was to evaluate a laboratorial system of carbohydrate fractions to identify and quantify the fractions that compose this nutrient. The following fractions were determined: simple sugars (SS using the colorimetric phenol-sulfuric method; digestible starch (DS and resistant starch (RS by enzymatic digestions; total fiber (TF using the enzymic-gravimetric method; neutral detergent fiber (NDF and soluble fiber (SF estimated by difference TF - NDF, in grains of corn and sorghum, citric pulp, wheat middlings, wheat mills and rice bran. The coefficient of variation for fractions SS, DS, RS, TF and NDF varied from 4.81 to 19.17%; 4.58 to 15.03%; 2.42 to 9.91%; 1.23 to 8.23% and 1.16 to 8.42%; respectively. A good repeatability of the method used was observed. The fraction identified the main groups of carbohydrates composed on the food and it can be a reference to future works.

  14. Real-Time Microbiology Laboratory Surveillance System to Detect Abnormal Events and Emerging Infections, Marseille, France.

    Science.gov (United States)

    Abat, Cédric; Chaudet, Hervé; Colson, Philippe; Rolain, Jean-Marc; Raoult, Didier

    2015-08-01

    Infectious diseases are a major threat to humanity, and accurate surveillance is essential. We describe how to implement a laboratory data-based surveillance system in a clinical microbiology laboratory. Two historical Microsoft Excel databases were implemented. The data were then sorted and used to execute the following 2 surveillance systems in Excel: the Bacterial real-time Laboratory-based Surveillance System (BALYSES) for monitoring the number of patients infected with bacterial species isolated at least once in our laboratory during the study periodl and the Marseille Antibiotic Resistance Surveillance System (MARSS), which surveys the primary β-lactam resistance phenotypes for 15 selected bacterial species. The first historical database contained 174,853 identifications of bacteria, and the second contained 12,062 results of antibiotic susceptibility testing. From May 21, 2013, through June 4, 2014, BALYSES and MARSS enabled the detection of 52 abnormal events for 24 bacterial species, leading to 19 official reports. This system is currently being refined and improved.

  15. Solar-wind ion interaction with carbonates on the surface of Ceres: Laboratory Experiments

    Science.gov (United States)

    Dukes, C. A.; Bu, C.; Lopez, G. R.; McFadden, L. A.; Ruesch, O.; Li, J. Y.

    2017-12-01

    Bright carbonates deposits on the dark background of Ceres have been identified by Dawn's VIR spectrometer [1, 2], with a composition that varies from Na2CO3 at Oxo crater and the Cerealia and Vinalia Faculae where carbonates are most abundant, to MgCO3 or CaCO3 in other regions [2, 3]. Solar-wind plasma impacts the surface of airless planetary bodies with 1 keV/amu H and He ( 107 ions cm-2 s-1at 2.8 A.U.), causing chemical and physical changes that influence the optical spectra. We investigate the stability of carbonate salts under ion irradiation, monitoring the spectral and compositional change. Anhydrous Na2CO3 (natrite) powders (grains 80% original material reflectance. Both hydrous and anhydrous Na2CO3 show blue/green radio-luminescence under ion impact. Ion-induced darkening of Ceres' natrite deposits is expected to occur on a time-scale of 100 - 1000 years, significantly less than the age of Cerealia facula 7 Ma [4]; darkening can be reversed by exposure to water vapor. For Ceres bright regions of varied albedo, this suggests that the brightest areas are the more recent deposits or the most recently exposed to water by upwelling, venting, or sublimation of subsurface ice [5]. [1] DeSanctis et al (2016) Nature 536, 54 - 57 [2] Palumbo et al (2016) LPSC 47, 2166 [3] Tosi et al (2016) DPS48, 511.06 [4] Nathues et al (2017) APJ 153, 112-124 [5] Titus (2015) GRL 42, 2130-2136

  16. Laboratory Study of Topographic Effects on the Near-surface Tornado Flow Field

    Science.gov (United States)

    Razavi, Alireza; Sarkar, Partha P.

    2018-03-01

    To study topographic effects on the near-surface tornado flow field, the Iowa State University tornado simulator was used to simulate a translating tornado passing over three different two-dimensional topographies: a ridge, an escarpment and a valley. The effect of the translation speed on maximum horizontal wind speeds is observed for translation speeds of 0.15 and 0.50 m s^{-1} , with the lower value resulting in a larger maximum horizontal wind speed. The tornado translation over the three topographies with respect to flat terrain is assessed for changes in: (a) the maximum horizontal wind speeds in terms of the flow-amplification factor; (b) the maximum aerodynamic drag in terms of the tornado speed-up ratio; (c) the maximum duration of exposure at any location to high wind speeds of a specific range in terms of the exposure amplification factor. Results show that both the maximum wind amplification factor of 14%, as well as the maximum speed-up ratio of 14%, occur on the ridge. For all topographies, the increase in aerodynamic drag is observed to be maximized for low-rise buildings, which illustrates the importance of the vertical profiles of the horizontal wind speed near the ground. The maximum exposure amplification factors, estimated for the range of wind speeds corresponding to the EF2 (50-60 m s^{-1} ) and EF3 (61-75 m s^{-1}) scales, are 86 and 110% for the ridge, 4 and 60% for the escarpment and - 6 and 47% for the valley, respectively.

  17. The computerised accountancy system (MYDAS) for irradiated components in RNL's Mayfair Laboratory at Culcheth

    International Nuclear Information System (INIS)

    Stansfield, R.G.; Baker, A.R.

    1985-09-01

    The computerised Mayfair Accountancy System (MYDAS) has been developed to account for irradiated components in the Mayfair Laboratory at Culcheth and supersedes a card-index system. The computerised system greatly improves the availability of the data held and it ensures, by means of extensive data validation programs, that the data accurately represent the current inventory of irradiated components in the Laboratory. The system has been implemented on the Risley ICL 2966 main-frame computer and uses an IDMS database to store the data. The computer is accessed through the facilities of the Transaction Processing Management System (TPMS) providing rapid and secure access to the database from several visual display units and printers simultaneously. (author)

  18. The technical and economic feasibility of establishing a building system integration laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Crawley, D.B.; Drost, M.K.; Johnson, B.M.

    1989-09-01

    On December 22, 1987, the US Congress provided funding to the US Department of Energy (DOE) to study the feasibility and conceptual design of a whole building system integration laboratory'' (Title II of Pub. L. 100--202). A whole-building system integration laboratory would be a full-scale experimental facility in which the energy performance interactions of two or more building components, e.g., walls, windows, lighting, could be tested under actual operating conditions. At DOE's request, the Pacific Northwest Laboratory (PNL) conducted the study with the assistance of a technical review and representing other federal agencies and the academic and private sectors, including professional societies, building component manufacturers, and building research organizations. The results of the feasibility study are presented in this report.

  19. A surface refractive index scanning system and method

    DEFF Research Database (Denmark)

    2015-01-01

    The invention relates to a surface refractive index scanning system for characterization of a sample. The system comprises a grating device for holding or receiving the sample, the device comprising at least a first grating region having a first grating width along a transverse direction, and a s......The invention relates to a surface refractive index scanning system for characterization of a sample. The system comprises a grating device for holding or receiving the sample, the device comprising at least a first grating region having a first grating width along a transverse direction...

  20. Electron/positron measurements obtained with the Mars Science Laboratory Radiation Assessment Detector on the surface of Mars

    Energy Technology Data Exchange (ETDEWEB)

    Koehler, J.; Wimmer-Schweingruber, R.F.; Appel, J. [Kiel Univ. (Germany). Inst. of Experimental and Applied Physics; and others

    2016-04-01

    The Radiation Assessment Detector (RAD), on board the Mars Science Laboratory (MSL) rover Curiosity, measures the energetic charged and neutral particles and the radiation dose rate on the surface of Mars. Although charged and neutral particle spectra have been investigated in detail, the electron and positron spectra have not been investigated yet. The reason for that is that they are difficult to separate from each other and because of the technical challenges involved in extracting energy spectra from the raw data. We use GEANT4 to model the behavior of the RAD instrument for electron/positron measurements.We compare Planetocosmics predictions for different atmospheric pressures and different modulation parameters Φ with the obtained RAD electron/positron measurements.We find that the RAD electron/positron measurements agree well with the spectra predicted by Planetocosmics. Both RAD measurements and Planetocosmics simulation show a dependence of the electron/positron fluxes on both atmospheric pressure and solar modulation potential.

  1. Metolachlor and atrazine fate in surface water systems

    Energy Technology Data Exchange (ETDEWEB)

    Rice, P.J.; Anderson, T.A.; Coats, J.R. [Iowa State Univ., Ames, IA (United States)

    1995-12-31

    The detection of pesticides in surface water and ground water provokes concern involving human health risks associated with pesticide exposure. Monitoring studies of surface waters have detected concentrations of herbicides that exceed the U.S. Environmental Protection Agency proposed maximum contamination level (MCL) for drinking water. Conventional water treatment processes do not remove many herbicides. Tap water drawn from surface-water sources has been reported to contain levels of herbicides above the regulatory limits. There is current interest in the use of artificial wetlands and macrophyte-cultured ponds in waste-water-treatment systems. Aquatic plant-based water treatment systems improve waste water effluent by solid filtration and nutrient assimilation. Various aquatic plants have been shown to accumulate metals, absorb inorganic ions, and accelerate the biodegradation of complex organics. Our research evaluates the fate of metolachlor and atrazine in surface water, surface water/sediment, and surface water/aquatic plant incubation systems to study the influence of sediment and aquatic plants in the removal and biotransformation of herbicides from contaminated waters. Aquatic macrophyte systems may prove to be useful in the remediation of herbicide contaminated surface waters in water treatment facilities or in the reduction of herbicide concentrations from tile drain effluents prior to entering watersheds.

  2. Hydrogeological characterization on surface-based investigation phase in the Mizunami underground research laboratory project, in Japan

    International Nuclear Information System (INIS)

    Saegusa, Hiromitsu; Onoe, Hironori; Takeuchi, Shinji; Takeuchi, Ryuji; Ohyama, Takuya

    2007-01-01

    The Mizunami Underground Research Laboratory (MIU) project is being carried out by Japan Atomic Energy Agency in the Cretaceous Toki granite in the Tono area, central Japan. The MIU project is a purpose-built generic underground research laboratory project that is planned for a broad scientific study of the deep geological environment as a basis of research and development for geological disposal of nuclear wastes. One of the main goals of the MIU project is to establish comprehensive techniques for investigation, analysis, and assessment of the deep geological environment. The MIU project has three overlapping phases: Surface-based Investigation (Phase I), Construction (Phase II) and Operation (Phase III). Hydrogeological investigations using a stepwise process in Phase I have been carried out in order to obtain information on important properties such as, location of water conducting features, hydraulic conductivity and so on. Hydrogeological modeling and groundwater flow simulations in Phase I have been carried out in order to synthesize these investigation results, to evaluate the uncertainty of the hydrogeological model and to identify the main issues for further investigations. Using the stepwise hydrogeological characterization approach and combining the investigation with modeling and simulation, understanding of the hydrogeological environment has been progressively improved. (authors)

  3. Cost and implementation analysis of a personal digital assistant system for laboratory data collection.

    Science.gov (United States)

    Blaya, J A; Gomez, W; Rodriguez, P; Fraser, H

    2008-08-01

    One hundred and twenty-six public health centers and laboratories in Lima, Peru, without internet. We have previously shown that a personal digital assistant (PDA) based system reduces data collection delays and errors for tuberculosis (TB) laboratory results when compared to a paper system. To assess the data collection efficiency of each system and the resources required to develop, implement and transfer the PDA-based system to a resource-poor setting. Time-motion study of data collectors using the PDA-based and paper systems. Cost analysis of developing, implementing and transferring the PDA-based system to a local organization and their redeployment of the system. Work hours spent collecting and processing results decreased by 60% (P collecting patient weights was $4107. A PDA-based system drastically reduced the effort required to collect TB laboratory results from remote locations. With the framework described, open-source software and local development, organizations in resource-poor settings could reap the benefits of this technology.

  4. Evaluation of Cavity Collapse and Surface Crater Formation for Selected Lawrence Livermore National Laboratory Underground Nuclear Tests - 2007

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, S K; Pawloski, G A; Raschke, K

    2007-04-26

    This report describes evaluation of collapse evolution for selected LLNL underground nuclear tests at the Nevada Test Site (NTS). The work is being done at the request of NSTec and supports the Department of Energy National Nuclear Security Association Nevada Site Office Borehole Management Program (BMP). The primary objective of this program is to close (plug) weapons program legacy boreholes that are deemed no longer useful. Safety decisions must be made before a crater area, or potential crater area, can be reentered for any work. Our statements on cavity collapse and crater formation are input into their safety decisions. The BMP is an on-going program to address hundreds of boreholes at the NTS. Each year NSTec establishes a list of holes to be addressed. They request the assistance of the Lawrence Livermore National Laboratory and Los Alamos National Laboratory Containment Programs to provide information related to the evolution of collapse history and make statements on completeness of collapse as relates to surface crater stability. These statements do not include the effects of erosion that may modify the collapse craters over time. They also do not address possible radiation dangers that may be present. Subject matter experts from the LLNL Containment Program and the Chemical Sciences Division who had been active in weapons testing activities performed these evaluations. Information used included drilling and hole construction, emplacement and stemming, timing and sequence of the selected test and nearby tests, geology, yield, depth of burial, collapse times, surface crater sizes, cavity and crater volume estimations, and ground motion. Both classified and unclassified data were reviewed. Various amounts of information are available for these tests, depending on their age and other associated activities. Lack of data can hamper evaluations and introduce uncertainty. We make no attempt to quantify this uncertainty. The following unclassified summary

  5. Particle surface area and bacterial activity in recirculating aquaculture systems

    DEFF Research Database (Denmark)

    Pedersen, Per Bovbjerg; von Ahnen, Mathis; Fernandes, Paulo

    2017-01-01

    Suspended particles in recirculating aquaculture systems (RAS) provide surface area that can be colonized by bacteria. More particles accumulate as the intensity of recirculation increases thus potentially increasing the bacterial carrying capacity of the systems. Applying a recent, rapid, cultur...... for determining bacterial activity might provide a means for future monitoring and assessment of microbial water quality in aquaculture farming systems......Suspended particles in recirculating aquaculture systems (RAS) provide surface area that can be colonized by bacteria. More particles accumulate as the intensity of recirculation increases thus potentially increasing the bacterial carrying capacity of the systems. Applying a recent, rapid, culture......-independent fluorometric detection method (Bactiquant®) for measuring bacterial activity, the current study explored the relationship between total particle surface area (TSA, derived from the size distribution of particles >5 μm) and bacterial activity in freshwater RAS operated at increasing intensity of recirculation...

  6. Reliability research on nuclear I and C system at KAIST NIC laboratory

    International Nuclear Information System (INIS)

    Seong, Poong-Hyun

    1996-01-01

    As the use of computer systems becomes popular in nuclear industry, reliability assurance of digitized nuclear instrumentation and control systems is becoming one of hot issues. Some issues on this are S/W verification and validation, reliability estimation of digital systems, development strategy of high integrity knowledge base for expert systems, and so on. In order to address these issues, the Nuclear Instrumentation and Control (NIC) laboratory at KAIST is conducting some research projects. This paper describes some highlights of these research activities. The final goal of these research activities is to develop some useful methodologies and tools for development of dependable digital nuclear instrument and control systems. (author)

  7. The evolution of a LIMS (laboratory information management system). [Chemical analyses at BNFL

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1992-04-01

    Changes in the world and United Kingdom markets for nuclear fuels during the 1990s have prompted British Nuclear Fuels (BNFL) to maximise cost effectiveness in its Chemical and Metallurgical Services department. A laboratory information management system (LIMS) was introduced in order to keep records of analytical techniques and equipment up to date by coordinating various computer systems. Wherever possible automated systems have replaced traditional, labour intensive techniques. So successful has the LIMS system been, that the team now hopes to expand into expert systems. (UK).

  8. Surface water sampling and analysis plan for environmental monitoring in Waste Area Grouping 6 at Oak Ridge National Laboratory, Oak Ridge, Tennessee. Environmental Restoration Program

    Energy Technology Data Exchange (ETDEWEB)

    1994-06-01

    This Sampling and Analysis Plan addresses surface water monitoring, sampling, and analysis activities that will be conducted in support of the Environmental Monitoring Plan for Waste Area Grouping (WAG) 6. WAG 6 is a shallow-burial land disposal facility for low-level radioactive waste at the Oak Ridge National Laboratory, a research facility owned by the US Department of Energy and managed by Martin Marietta Energy Systems, Inc. Surface water monitoring will be conducted at nine sites within WAG 6. Activities to be conducted will include the installation, inspection, and maintenance of automatic flow-monitoring and sampling equipment and manual collection of various water and sediment samples. The samples will be analyzed for various organic, inorganic, and radiological parameters. The information derived from the surface water monitoring, sampling, and analysis will aid in evaluating risk associated with contaminants migrating off-WAG, and will be used in calculations to establish relationships between contaminant concentration (C) and flow (Q). The C-Q relationship will be used in calculating the cumulative risk associated with the off-WAG migration of contaminants.

  9. Surface water sampling and analysis plan for environmental monitoring in Waste Area Grouping 6 at Oak Ridge National Laboratory, Oak Ridge, Tennessee. Environmental Restoration Program

    International Nuclear Information System (INIS)

    1994-06-01

    This Sampling and Analysis Plan addresses surface water monitoring, sampling, and analysis activities that will be conducted in support of the Environmental Monitoring Plan for Waste Area Grouping (WAG) 6. WAG 6 is a shallow-burial land disposal facility for low-level radioactive waste at the Oak Ridge National Laboratory, a research facility owned by the US Department of Energy and managed by Martin Marietta Energy Systems, Inc. Surface water monitoring will be conducted at nine sites within WAG 6. Activities to be conducted will include the installation, inspection, and maintenance of automatic flow-monitoring and sampling equipment and manual collection of various water and sediment samples. The samples will be analyzed for various organic, inorganic, and radiological parameters. The information derived from the surface water monitoring, sampling, and analysis will aid in evaluating risk associated with contaminants migrating off-WAG, and will be used in calculations to establish relationships between contaminant concentration (C) and flow (Q). The C-Q relationship will be used in calculating the cumulative risk associated with the off-WAG migration of contaminants

  10. Surface Moisture Measurement System Operation and Maintenance Manual

    International Nuclear Information System (INIS)

    Ritter, G.A.; Pearce, K.L.; Stokes, T.L.

    1995-12-01

    This operations and maintenance manual addresses deployment, equipment and field hazards, operating instructions, calibration verification, removal, maintenance, and other pertinent information necessary to safely operate and store the Surface Moisture Measurement System (SMMS) and Liquid Observation Well Moisture Measurement System (LOWMMS). These systems were developed primarily in support of Tank Waste Remediation System (TWRS) Safety Programs for moisture measurement in organic and ferrocyanide watch list tanks

  11. A continuous surface reconstruction method on point cloud captured from a 3D surface photogrammetry system

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Wenyang [Department of Bioengineering, University of California, Los Angeles, California 90095 (United States); Cheung, Yam; Sabouri, Pouya; Arai, Tatsuya J.; Sawant, Amit [Department of Radiation Oncology, University of Texas Southwestern, Dallas, Texas 75390 (United States); Ruan, Dan, E-mail: druan@mednet.ucla.edu [Department of Bioengineering, University of California, Los Angeles, California 90095 and Department of Radiation Oncology, University of California, Los Angeles, California 90095 (United States)

    2015-11-15

    Purpose: To accurately and efficiently reconstruct a continuous surface from noisy point clouds captured by a surface photogrammetry system (VisionRT). Methods: The authors have developed a level-set based surface reconstruction method on point clouds captured by a surface photogrammetry system (VisionRT). The proposed method reconstructs an implicit and continuous representation of the underlying patient surface by optimizing a regularized fitting energy, offering extra robustness to noise and missing measurements. By contrast to explicit/discrete meshing-type schemes, their continuous representation is particularly advantageous for subsequent surface registration and motion tracking by eliminating the need for maintaining explicit point correspondences as in discrete models. The authors solve the proposed method with an efficient narrowband evolving scheme. The authors evaluated the proposed method on both phantom and human subject data with two sets of complementary experiments. In the first set of experiment, the authors generated a series of surfaces each with different black patches placed on one chest phantom. The resulting VisionRT measurements from the patched area had different degree of noise and missing levels, since VisionRT has difficulties in detecting dark surfaces. The authors applied the proposed method to point clouds acquired under these different configurations, and quantitatively evaluated reconstructed surfaces by comparing against a high-quality reference surface with respect to root mean squared error (RMSE). In the second set of experiment, the authors applied their method to 100 clinical point clouds acquired from one human subject. In the absence of ground-truth, the authors qualitatively validated reconstructed surfaces by comparing the local geometry, specifically mean curvature distributions, against that of the surface extracted from a high-quality CT obtained from the same patient. Results: On phantom point clouds, their method

  12. A continuous surface reconstruction method on point cloud captured from a 3D surface photogrammetry system.

    Science.gov (United States)

    Liu, Wenyang; Cheung, Yam; Sabouri, Pouya; Arai, Tatsuya J; Sawant, Amit; Ruan, Dan

    2015-11-01

    To accurately and efficiently reconstruct a continuous surface from noisy point clouds captured by a surface photogrammetry system (VisionRT). The authors have developed a level-set based surface reconstruction method on point clouds captured by a surface photogrammetry system (VisionRT). The proposed method reconstructs an implicit and continuous representation of the underlying patient surface by optimizing a regularized fitting energy, offering extra robustness to noise and missing measurements. By contrast to explicit/discrete meshing-type schemes, their continuous representation is particularly advantageous for subsequent surface registration and motion tracking by eliminating the need for maintaining explicit point correspondences as in discrete models. The authors solve the proposed method with an efficient narrowband evolving scheme. The authors evaluated the proposed method on both phantom and human subject data with two sets of complementary experiments. In the first set of experiment, the authors generated a series of surfaces each with different black patches placed on one chest phantom. The resulting VisionRT measurements from the patched area had different degree of noise and missing levels, since VisionRT has difficulties in detecting dark surfaces. The authors applied the proposed method to point clouds acquired under these different configurations, and quantitatively evaluated reconstructed surfaces by comparing against a high-quality reference surface with respect to root mean squared error (RMSE). In the second set of experiment, the authors applied their method to 100 clinical point clouds acquired from one human subject. In the absence of ground-truth, the authors qualitatively validated reconstructed surfaces by comparing the local geometry, specifically mean curvature distributions, against that of the surface extracted from a high-quality CT obtained from the same patient. On phantom point clouds, their method achieved submillimeter

  13. MDAS2: A Data Acquisition System for the Soil Mechanic Laboratory

    International Nuclear Information System (INIS)

    Alberdi, J.; Barcala, J. M.

    2000-01-01

    The Soil Mechanic Laboratory in CIEMAT is working to characterize a bentonite which may be use in the storage of radioactive waste. The bentonite is studied with several tests, frequently used in soil mechanics. This document describes the data acquisition system used in one of these experiments

  14. Stable and optimal fuzzy control of a laboratory Antilock Braking System

    DEFF Research Database (Denmark)

    Precup, Radu-Emil; Spataru, Sergiu; Petriu, Emil M.

    2010-01-01

    This paper discusse four new Takagi-Sugeno fuzzy controllers (T-S FCs) for the longitudinal slip control of an Antilock Braking System laboratory equipment. Two discretetime dynamic Takagi-Sugeno fuzzy models of the controlled plant are derived based on the parameters in the consequents of the ru...

  15. An Embedded Systems Laboratory to Support Rapid Prototyping of Robotics and the Internet of Things

    Science.gov (United States)

    Hamblen, J. O.; van Bekkum, G. M. E.

    2013-01-01

    This paper describes a new approach for a course and laboratory designed to allow students to develop low-cost prototypes of robotic and other embedded devices that feature Internet connectivity, I/O, networking, a real-time operating system (RTOS), and object-oriented C/C++. The application programming interface (API) libraries provided permit…

  16. The significance of a usability evaluation of an emerging laboratory order entry system

    NARCIS (Netherlands)

    Peute, Linda W. P.; Jaspers, Monique W. M.

    2007-01-01

    OBJECTIVES: To assess the usability of an emerging POE system, OM/Lab, for the computer-supported ordering of laboratory tests. We were more specifically interested in the relation of the usability problems detected in the user testing sessions with the order behaviour in terms of efficiency and

  17. A Simple System for Observing Dynamic Phase Equilibrium via an Inquiry-Based Laboratory or Demonstration

    Science.gov (United States)

    Cloonan, Carrie A.; Andrew, Julie A.; Nichol, Carolyn A.; Hutchinson, John S.

    2011-01-01

    This article describes an activity that can be used as an inquiry-based laboratory or demonstration for either high school or undergraduate chemistry students to provide a basis for understanding both vapor pressure and the concept of dynamic phase equilibrium. The activity includes a simple setup to create a closed system of only water liquid and…

  18. Fingering in unsaturated zone flow: a qualitative review with laboratory experiments on heterogeneous systems

    CSIR Research Space (South Africa)

    Sililo, OTN

    2000-11-01

    Full Text Available Unstable unsaturated zone flow (fingering) is a potentially important process in recharge, pollution, and surface water/ground water body interactions. Extending previous workers ' studies on homogeneous systems, sand tank experiments have been...

  19. [Clinical governance and patient safety culture in clinical laboratories in the Spanish National Health System].

    Science.gov (United States)

    Giménez-Marín, Á; Rivas-Ruiz, F

    To conduct a situational analysis of patient safety culture in public laboratories in the Spanish National Health System and to determine the clinical governance variables that most strongly influence patient safety. A descriptive cross-sectional study was carried out, in which a Survey of Patient Safety in Clinical Laboratories was addressed to workers in 26 participating laboratories. In this survey, which consisted of 45 items grouped into 6 areas, scores were assigned on a scale from 0 to 100 (where 0 is the lowest perception of patient safety). Laboratory managers were asked specific questions about quality management systems and technology. The mean scores for the 26 participating hospitals were evaluated, and the following results observed: in 4of the 6areas, the mean score was higher than 70 points. In the third area (equipment and resources) and the fourth area (working conditions), the scores were lower than 60 points. Every hospital had a digital medical record system. This 100% level of provision was followed by that of an electronic request management system, which was implemented in 82.6% of the hospitals. The results obtained show that the culture of security is homogeneous and of high quality in health service laboratories, probably due to the steady improvement observed. However, in terms of clinical governance, there is still some way to go, as shown by the presence of weaknesses in crucial dimensions of safety culture, together with variable levels of implementation of fail-safe technologies and quality management systems. Copyright © 2017 SECA. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. RFID based Anti-theft System for Metropolia UAS Electronics laboratories

    OpenAIRE

    Weldemedhin, Desta

    2016-01-01

    The aim of this thesis is to study different types of RFID based anti-Theft system implementation suitable for Metropolia Electronics laboratory environment to deter theft taking into account several installation requirements. The operating frequencies of the RFID anti-theft system are from low frequency to High frequencies range and governed by different standards based on the region it is going to be implemented. The introduction of this thesis will go through Radio Frequency Identifica...

  1. Isotopic power supplies for space and terrestrial systems: quality assurance by Sandia National Laboratories

    International Nuclear Information System (INIS)

    Hannigan, R.L.; Harnar, R.R.

    1981-09-01

    The Sandia National Laboratories participation in Quality Assurance (QA) programs for Radioisotopic Thermoelectric Generators which have been used in space and terrestrial systems over the past 15 years is summarized. Basic elements of the program are briefly described and recognition of assistance from other Sandia organizations is included. Descriptions of the various systems for which Sandia has had the QA responsibility are also presented. In addition, the outlook for Sandia participation in RTG programs for the next several years is noted

  2. Isotopic power supplies for space and terrestrial systems: quality assurance by Sandia National Laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Hannigan, R.L.; Harnar, R.R.

    1981-09-01

    The Sandia National Laboratories participation in Quality Assurance (QA) programs for Radioisotopic Thermoelectric Generators which have been used in space and terrestrial systems over the past 15 years is summarized. Basic elements of the program are briefly described and recognition of assistance from other Sandia organizations is included. Descriptions of the various systems for which Sandia has had the QA responsibility are also presented. In addition, the outlook for Sandia participation in RTG programs for the next several years is noted.

  3. Stepwise approach to establishing multiple outreach laboratory information system-electronic medical record interfaces.

    Science.gov (United States)

    Pantanowitz, Liron; Labranche, Wayne; Lareau, William

    2010-05-26

    Clinical laboratory outreach business is changing as more physician practices adopt an electronic medical record (EMR). Physician connectivity with the laboratory information system (LIS) is consequently becoming more important. However, there are no reports available to assist the informatician with establishing and maintaining outreach LIS-EMR connectivity. A four-stage scheme is presented that was successfully employed to establish unidirectional and bidirectional interfaces with multiple physician EMRs. This approach involves planning (step 1), followed by interface building (step 2) with subsequent testing (step 3), and finally ongoing maintenance (step 4). The role of organized project management, software as a service (SAAS), and alternate solutions for outreach connectivity are discussed.

  4. Distributed Energy Technology Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Distributed Energy Technologies Laboratory (DETL) is an extension of the power electronics testing capabilities of the Photovoltaic System Evaluation Laboratory...

  5. Evaluation of Cavity Collapse and Surface Crater Formation for Selected Lawrence Livermore National Laboratory Underground Nuclear Tests - 2011, Part 2

    Energy Technology Data Exchange (ETDEWEB)

    Pawloski, G A

    2012-01-30

    This report evaluates collapse evolution for selected Lawrence Livermore National Laboratory (LLNL) underground nuclear tests at the Nevada National Security Site (NNSS, formerly called the Nevada Test Site). The work is being done to support several different programs that desire access to the ground surface above expended underground nuclear tests. The programs include: the Borehole Management Program, the Environmental Restoration Program, and the National Center for Nuclear Security Gas-Migration Experiment. Safety decisions must be made before a crater area, or potential crater area, can be reentered for any work. Evaluation of cavity collapse and crater formation is input into the safety decisions. Subject matter experts from the LLNL Containment Program who participated in weapons testing activities perform these evaluations. Information used included drilling and hole construction, emplacement and stemming, timing and sequence of the selected test and nearby tests, geology, yield, depth of burial, collapse times, surface crater sizes, cavity and crater volume estimations, ground motion, and radiological release information. Both classified and unclassified data were reviewed. The evaluations do not include the effects of erosion that may modify the collapse craters over time. They also do not address possible radiation dangers that may be present. Various amounts of information are available for these tests, depending on their age and other associated activities. Lack of data can hamper evaluations and introduce uncertainty. We make no attempt to quantify this uncertainty. Evaluation of Cavity Collapse and Surface Crater Formation for Selected Lawrence Livermore National Laboratory Underground Nuclear Tests - 2011 was published on March 2, 2011. This report, considered Part 2 of work undertaken in calendar year 2011, compiles evaluations requested after the March report. The following unclassified summary statements describe collapse evolution and crater

  6. TECHNICAL VISION SYSTEM FOR THE ROBOTIC MODEL OF SURFACE VESSEL

    Directory of Open Access Journals (Sweden)

    V. S. Gromov

    2016-07-01

    Full Text Available The paper presents results of work on creation of technical vision systems within the training complex for the verification of control systems by the model of surface vessel. The developed system allows determination of the coordinates and orientation angle of the object of control by means of an external video camera on one bench mark and without the need to install additional equipment on the object of control itself. Testing of the method was carried out on the robotic complex with the model of a surface vessel with a length of 430 mm; coordinates of the control object were determined with the accuracy of 2 mm. This method can be applied as a subsystem of receiving coordinates for systems of automatic control of surface vessels when testing on the scale models.

  7. Develop virtual joint laboratory for education like distance engineering system for robotic applications

    Science.gov (United States)

    Latinovic, T. S.; Deaconu, S. I.; Latinović, M. T.; Malešević, N.; Barz, C.

    2015-06-01

    This paper work with a new system that provides distance learning and online training engineers. The purpose of this paper is to develop and provide web-based system for the handling and control of remote devices via the Internet. Remote devices are currently the industry or mobile robots [13]. For future product development machine in the factory will be included in the system. This article also discusses the current use of virtual reality tools in the fields of science and engineering education. One programming tool in particular, virtual reality modeling language (VRML) is presented in the light of its applications and capabilities in the development of computer visualization tool for education. One contribution of this paper is to present the software tools and examples that can encourage educators to develop a virtual reality model to improve teaching in their discipline. [12] This paper aims to introduce a software platform, called VALIP where users can build, share, and manipulate 3D content in cooperation with the interaction processes in a 3D context, while participating hardware and software devices can be physical and / or logical distributed and connected together via the Internet. VALIP the integration of virtual laboratories to appropriate partners; therefore, allowing access to all laboratories in any of the partners in the project. VALIP provides advanced laboratory for training and research within robotics and production engineering, and thus, provides a great laboratory facilities with only having to invest a limited amount of resources at the local level to the partner site.

  8. Implementation of quality management systems and progress towards accreditation of National Tuberculosis Reference Laboratories in Africa

    Directory of Open Access Journals (Sweden)

    Heidi Albert

    2017-03-01

    Full Text Available Background: Laboratory services are essential at all stages of the tuberculosis care cascade, from diagnosis and drug resistance testing to monitoring response to treatment. Enabling access to quality services is a challenge in low-resource settings. Implementation of a strong quality management system (QMS and laboratory accreditation are key to improving patient care. Objectives: The study objective was to determine the status of QMS implementation and progress towards accreditation of National Tuberculosis Reference Laboratories (NTRLs in the African Region. Method: An online questionnaire was administered to NTRL managers in 47 World Health Organization Regional Office for Africa member states in the region, between February and April 2015, regarding the knowledge of QMS tools and progress toward implementation to inform strategies for tuberculosis diagnostic services strengthening in the region. Results: A total of 21 laboratories (43.0% had received SLMTA/TB-SLMTA training, of which 10 had also used the Global Laboratory Initiative accreditation tool. However, only 36.7% of NTRLs had received a laboratory audit, a first step in quality improvement. Most NTRLs participated in acid-fast bacilli microscopy external quality assurance (95.8%, although external quality assurance for other techniques was lower (60.4% for first-line drug susceptibility testing, 25.0% for second-line drug susceptibility testing, and 22.9% for molecular testing. Barriers to accreditation included lack of training and accreditation programmes. Only 28.6%of NTRLs had developed strategic plans and budgets which included accreditation. Conclusion: Good foundations are in place on the continent from which to scale up accreditation efforts. Laboratory audits should be conducted as a first step in developing quality improvement action plans. Political commitment and strong leadership are needed to drive accreditation efforts; advocacy will require clear evidence of patient

  9. Cost evaluation of clinical laboratory in Taiwan's National Health System by using activity-based costing.

    Science.gov (United States)

    Su, Bin-Guang; Chen, Shao-Fen; Yeh, Shu-Hsing; Shih, Po-Wen; Lin, Ching-Chiang

    2016-11-01

    To cope with the government's policies to reduce medical costs, Taiwan's healthcare service providers are striving to survive by pursuing profit maximization through cost control. This article aimed to present the results of cost evaluation using activity-based costing performed in the laboratory in order to throw light on the differences between costs and the payment system of National Health Insurance (NHI). This study analyzed the data of costs and income of the clinical laboratory. Direct costs belong to their respective sections of the department. The department's shared costs, including public expenses and administrative assigned costs, were allocated to the department's respective sections. A simple regression equation was created to predict profit and loss, and evaluate the department's break-even point, fixed cost, and contribution margin ratio. In clinical chemistry and seroimmunology sections, the cost per test was lower than the NHI payment and their major laboratory tests had revenues with the profitability ratio of 8.7%, while the other sections had a higher cost per test than the NHI payment and their major tests were in deficit. The study found a simple linear regression model as follows: "Balance=-84,995+0.543×income (R2=0.544)". In order to avoid deficit, laboratories are suggested to increase test volumes, enhance laboratory test specialization, and become marginal scale. A hospital could integrate with regional medical institutions through alliances or OEM methods to increase volumes to reach marginal scale and reduce laboratory costs, enhancing the level and quality of laboratory medicine.

  10. Effects of earthquake induced rock shear on containment system integrity. Laboratory testing plan development

    Energy Technology Data Exchange (ETDEWEB)

    Read, Rodney S. (RSRead Consulting Inc. (Canada))

    2011-07-15

    This report describes a laboratory-scale testing program plan to address the issue of earthquake induced rock shear effects on containment system integrity. The document contains a review of relevant literature from SKB covering laboratory testing of bentonite clay buffer material, scaled analogue tests, and the development of related material models to simulate rock shear effects. The proposed testing program includes standard single component tests, new two-component constant volume tests, and new scaled analogue tests. Conceptual drawings of equipment required to undertake these tests are presented along with a schedule of tests. The information in this document is considered sufficient to engage qualified testing facilities, and to guide implementation of laboratory testing of rock shear effects. This document was completed as part of a collaborative agreement between SKB and Nuclear Waste Management Organization (NWMO) in Canada

  11. Effects of earthquake induced rock shear on containment system integrity. Laboratory testing plan development

    International Nuclear Information System (INIS)

    Read, Rodney S.

    2011-07-01

    This report describes a laboratory-scale testing program plan to address the issue of earthquake induced rock shear effects on containment system integrity. The document contains a review of relevant literature from SKB covering laboratory testing of bentonite clay buffer material, scaled analogue tests, and the development of related material models to simulate rock shear effects. The proposed testing program includes standard single component tests, new two-component constant volume tests, and new scaled analogue tests. Conceptual drawings of equipment required to undertake these tests are presented along with a schedule of tests. The information in this document is considered sufficient to engage qualified testing facilities, and to guide implementation of laboratory testing of rock shear effects. This document was completed as part of a collaborative agreement between SKB and Nuclear Waste Management Organization (NWMO) in Canada

  12. Cathode cooling systems for the magnetron and Penning H- sources: a progress report of work at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    McKenzie-Wilson, R.B.

    1977-01-01

    The magnetron/Penning H - sources being developed at Brookhaven National Laboratory have produced ion currents up to 1 A with pulse lengths of 10 ms. The pulse length is limited by heating of the cathode surface. Cathode thermal conditions were investigated and lead to the conclusion that a cathode cooling system must be capable of handling 3 kW cm -2 of heated cathode surface. A review of cooling fluid requirements coupled with an examination of possible cooling fluids, leads to the conclusion that demineralized water is a suitable cooling fluid when used under pressurized nucleated boiling conditions. A correlation is used to show that heat-flux of 1.25 kW cm -2 could be removed using current technology and that this heat flux may be extended to 3 kW cm -2 by use of the Hyper-Vapotron effect. The temperature of the working surface of the cathode may be varied over a small temperature range by varying the system pressure during operation

  13. Visualization Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Evaluates and improves the operational effectiveness of existing and emerging electronic warfare systems. By analyzing and visualizing simulation results...

  14. A pollution prevention chargeback system at Sandia National Laboratories, New Mexico

    International Nuclear Information System (INIS)

    Davis, R.; Fish, J.; Brown, C.

    1994-08-01

    Sandia National Laboratories, New Mexico (Sandia/NM) has successfully developed and implemented a chargeback system to fund the implementation of Pollution Prevention activities. In the process of establishing this system, many valuable lessons have been learned. This paper describes how the chargeback system currently functions, the benefits and drawbacks of implementing such a system, and recommendations for implementing a chargeback system at other facilities. The initial goals in establishing a chargeback system were to create (1) funding for pollution prevention implementation, including specific pollution prevention projects; and (2) awareness on the part of the line organizations of the quantities and types of waste that they generate, thus providing them with a direct incentive to reduce that waste. The chargeback system inputs waste generation data and then filters and sorts the data to serve two purposes: (1) the operation of the chargeback system; and (2) the detailed waste generation reporting used for assessing processes and identifying pollution prevention opportunities

  15. System design description for surface moisture measurement system (SMMS)

    Energy Technology Data Exchange (ETDEWEB)

    Vargo, G.F.

    1996-09-23

    The SMMS has been developed to measure moisture in the top few centimeters of tank waste. The SMMS development was initiated by the preliminary findings of SAR-033, and does not necessarily fulfill any established DQO. After the SAR-033 is released, if no significant changes are made, moisture measurements in the organic waste tanks will rapidly become a DQO. The SMMS was designed to be installed in any 4 inch or larger riser, and to allow maximum adjustability for riser lengths, and is used to deploy a sensor package on the waste surface within a 6 foot radius about the azimuth. The first sensor package will be a neutron probe.

  16. A tracking system for laboratory mice to support medical researchers in behavioral analysis.

    Science.gov (United States)

    Macrì, S; Mainetti, L; Patrono, L; Pieretti, S; Secco, A; Sergi, I

    2015-08-01

    The behavioral analysis of laboratory mice plays a key role in several medical and scientific research areas, such as biology, toxicology, pharmacology, and so on. Important information on mice behavior and their reaction to a particular stimulus is deduced from a careful analysis of their movements. Moreover, behavioral analysis of genetically modified mice allows obtaining important information about particular genes, phenotypes or drug effects. The techniques commonly adopted to support such analysis have many limitations, which make the related systems particularly ineffective. Currently, the engineering community is working to explore innovative identification and sensing technologies to develop new tracking systems able to guarantee benefits to animals' behavior analysis. This work presents a tracking solution based on passive Radio Frequency Identification Technology (RFID) in Ultra High Frequency (UHF) band. Much emphasis is given to the software component of the system, based on a Web-oriented solution, able to process the raw tracking data coming from a hardware system, and offer 2D and 3D tracking information as well as reports and dashboards about mice behavior. The system has been widely tested using laboratory mice and compared with an automated video-tracking software (i.e., EthoVision). The obtained results have demonstrated the effectiveness and reliability of the proposed solution, which is able to correctly detect the events occurring in the animals' cage, and to offer a complete and user-friendly tool to support researchers in behavioral analysis of laboratory mice.

  17. QCloud: A cloud-based quality control system for mass spectrometry-based proteomics laboratories.

    Science.gov (United States)

    Chiva, Cristina; Olivella, Roger; Borràs, Eva; Espadas, Guadalupe; Pastor, Olga; Solé, Amanda; Sabidó, Eduard

    2018-01-01

    The increasing number of biomedical and translational applications in mass spectrometry-based proteomics poses new analytical challenges and raises the need for automated quality control systems. Despite previous efforts to set standard file formats, data processing workflows and key evaluation parameters for quality control, automated quality control systems are not yet widespread among proteomics laboratories, which limits the acquisition of high-quality results, inter-laboratory comparisons and the assessment of variability of instrumental platforms. Here we present QCloud, a cloud-based system to support proteomics laboratories in daily quality assessment using a user-friendly interface, easy setup, automated data processing and archiving, and unbiased instrument evaluation. QCloud supports the most common targeted and untargeted proteomics workflows, it accepts data formats from different vendors and it enables the annotation of acquired data and reporting incidences. A complete version of the QCloud system has successfully been developed and it is now open to the proteomics community (http://qcloud.crg.eu). QCloud system is an open source project, publicly available under a Creative Commons License Attribution-ShareAlike 4.0.

  18. Downtime procedures for the 21st century: using a fully integrated health record for uninterrupted electronic reporting of laboratory results during laboratory information system downtimes.

    Science.gov (United States)

    Oral, Bulent; Cullen, Regina M; Diaz, Danny L; Hod, Eldad A; Kratz, Alexander

    2015-01-01

    Downtimes of the laboratory information system (LIS) or its interface to the electronic medical record (EMR) disrupt the reporting of laboratory results. Traditionally, laboratories have relied on paper-based or phone-based reporting methods during these events. We developed a novel downtime procedure that combines advance placement of orders by clinicians for planned downtimes, the printing of laboratory results from instruments, and scanning of the instrument printouts into our EMR. The new procedure allows the analysis of samples from planned phlebotomies with no delays, even during LIS downtimes. It also enables the electronic reporting of all clinically urgent results during downtimes, including intensive care and emergency department samples, thereby largely avoiding paper- and phone-based communication of laboratory results. With the capabilities of EMRs and LISs rapidly evolving, information technology (IT) teams, laboratories, and clinicians need to collaborate closely, review their systems' capabilities, and design innovative ways to apply all available IT functions to optimize patient care during downtimes. Copyright© by the American Society for Clinical Pathology.

  19. Design demonstrations for Category B tank systems at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1992-07-01

    This document presents design demonstrations conducted of liquid low-level waste (LLLW) storage tank systems located at the Oak Ridge National Laboratory (ORNL). ORNL has conducted research in energy related fields since 1943. The facilities used to conduct the research include nuclear reactors, chemical pilot plants, research laboratories, radioisotope production laboratories, and support facilities. These facilities have produced a variety of radioactive and/or hazardous wastes. These wastes have been stored and transported through an extensive network of piping and tankage. Demonstration of the design of these tank systems has been stipulated by the Federal Facility Agreement (FFA) between the US Environmental Protection Agency (EPA) - Region IV; the Tennessee Department of Environment and Conservation (TDEC); and the DOE. The FFA establishes four categories of tanks. These are: Category A -- New or Replacement Tank Systems with Secondary Containment; Category B -- Existing Tank Systems with Secondary Containment; Category C -- Existing Tank Systems without Secondary Containment; and Category D -- Existing Tank Systems without Secondary Containment that are; Removed from Service. This document provides a design demonstration of the secondary containment and ancillary equipment of 11 tank systems listed in the FFA as Category ''B.'' The design demonstration for each tank is presented in Section 2. The design demonstrations were developed using information obtained from the design drawings (as-built when available), construction specifications, and interviews with facility operators. The assessments assume that each tank system was constructed in accordance with the design drawings and construction specifications for that system unless specified otherwise. Each design demonstration addresses system conformance to the requirements of the FFA (Appendix F, Subsection C)

  20. DB4US: A Decision Support System for Laboratory Information Management.

    Science.gov (United States)

    Carmona-Cejudo, José M; Hortas, Maria Luisa; Baena-García, Manuel; Lana-Linati, Jorge; González, Carlos; Redondo, Maximino; Morales-Bueno, Rafael

    2012-11-14

    Until recently, laboratory automation has focused primarily on improving hardware. Future advances are concentrated on intelligent software since laboratories performing clinical diagnostic testing require improved information systems to address their data processing needs. In this paper, we propose DB4US, an application that automates information related to laboratory quality indicators information. Currently, there is a lack of ready-to-use management quality measures. This application addresses this deficiency through the extraction, consolidation, statistical analysis, and visualization of data related to the use of demographics, reagents, and turn-around times. The design and implementation issues, as well as the technologies used for the implementation of this system, are discussed in this paper. To develop a general methodology that integrates the computation of ready-to-use management quality measures and a dashboard to easily analyze the overall performance of a laboratory, as well as automatically detect anomalies or errors. The novelty of our approach lies in the application of integrated web-based dashboards as an information management system in hospital laboratories. We propose a new methodology for laboratory information management based on the extraction, consolidation, statistical analysis, and visualization of data related to demographics, reagents, and turn-around times, offering a dashboard-like user web interface to the laboratory manager. The methodology comprises a unified data warehouse that stores and consolidates multidimensional data from different data sources. The methodology is illustrated through the implementation and validation of DB4US, a novel web application based on this methodology that constructs an interface to obtain ready-to-use indicators, and offers the possibility to drill down from high-level metrics to more detailed summaries. The offered indicators are calculated beforehand so that they are ready to use when the user

  1. Validating the Technology Acceptance Model in the Context of the Laboratory Information System-Electronic Health Record Interface System

    Science.gov (United States)

    Aquino, Cesar A.

    2014-01-01

    This study represents a research validating the efficacy of Davis' Technology Acceptance Model (TAM) by pairing it with the Organizational Change Readiness Theory (OCRT) to develop another extension to the TAM, using the medical Laboratory Information Systems (LIS)--Electronic Health Records (EHR) interface as the medium. The TAM posits that it is…

  2. The EnzymeTracker: an open-source laboratory information management system for sample tracking.

    Science.gov (United States)

    Triplet, Thomas; Butler, Gregory

    2012-01-26

    In many laboratories, researchers store experimental data on their own workstation using spreadsheets. However, this approach poses a number of problems, ranging from sharing issues to inefficient data-mining. Standard spreadsheets are also error-prone, as data do not undergo any validation process. To overcome spreadsheets inherent limitations, a number of proprietary systems have been developed, which laboratories need to pay expensive license fees for. Those costs are usually prohibitive for most laboratories and prevent scientists from benefiting from more sophisticated data management systems. In this paper, we propose the EnzymeTracker, a web-based laboratory information management system for sample tracking, as an open-source and flexible alternative that aims at facilitating entry, mining and sharing of experimental biological data. The EnzymeTracker features online spreadsheets and tools for monitoring numerous experiments conducted by several collaborators to identify and characterize samples. It also provides libraries of shared data such as protocols, and administration tools for data access control using OpenID and user/team management. Our system relies on a database management system for efficient data indexing and management and a user-friendly AJAX interface that can be accessed over the Internet. The EnzymeTracker facilitates data entry by dynamically suggesting entries and providing smart data-mining tools to effectively retrieve data. Our system features a number of tools to visualize and annotate experimental data, and export highly customizable reports. It also supports QR matrix barcoding to facilitate sample tracking. The EnzymeTracker was designed to be easy to use and offers many benefits over spreadsheets, thus presenting the characteristics required to facilitate acceptance by the scientific community. It has been successfully used for 20 months on a daily basis by over 50 scientists. The EnzymeTracker is freely available online at http

  3. The EnzymeTracker: an open-source laboratory information management system for sample tracking

    Directory of Open Access Journals (Sweden)

    Triplet Thomas

    2012-01-01

    Full Text Available Abstract Background In many laboratories, researchers store experimental data on their own workstation using spreadsheets. However, this approach poses a number of problems, ranging from sharing issues to inefficient data-mining. Standard spreadsheets are also error-prone, as data do not undergo any validation process. To overcome spreadsheets inherent limitations, a number of proprietary systems have been developed, which laboratories need to pay expensive license fees for. Those costs are usually prohibitive for most laboratories and prevent scientists from benefiting from more sophisticated data management systems. Results In this paper, we propose the EnzymeTracker, a web-based laboratory information management system for sample tracking, as an open-source and flexible alternative that aims at facilitating entry, mining and sharing of experimental biological data. The EnzymeTracker features online spreadsheets and tools for monitoring numerous experiments conducted by several collaborators to identify and characterize samples. It also provides libraries of shared data such as protocols, and administration tools for data access control using OpenID and user/team management. Our system relies on a database management system for efficient data indexing and management and a user-friendly AJAX interface that can be accessed over the Internet. The EnzymeTracker facilitates data entry by dynamically suggesting entries and providing smart data-mining tools to effectively retrieve data. Our system features a number of tools to visualize and annotate experimental data, and export highly customizable reports. It also supports QR matrix barcoding to facilitate sample tracking. Conclusions The EnzymeTracker was designed to be easy to use and offers many benefits over spreadsheets, thus presenting the characteristics required to facilitate acceptance by the scientific community. It has been successfully used for 20 months on a daily basis by over 50

  4. An Experimental Study of Laboratory Hybrid Power System with the Hydrogen Technologies

    Directory of Open Access Journals (Sweden)

    Daniel Minarik

    2014-01-01

    Full Text Available This paper presents very small laboratory hybrid photovoltaic-hydrogen power system. The system was primarily assembled to verify the operability of the control algorithms and practical deployment of available commercial hydrogen technologies that are directly usable for storage of electricity produced from renewable energy sources in a small island system. This energetic system was installed and tested in Laboratory of fuel cells that is located in the university campus of VSB-Technical University of Ostrava. The energetic system consists of several basic components: a photovoltaic field, accumulators bank, water commercial electrolyzer and compact fuel cell system. The weather conditions recorded in two different weeks as model weather and solar conditions are used as case studies to test the energetic system and the results for two different cases are compared each other. The results show and illustrate selected behaviour curves of the power system and also average energy storage efficiency for accumulation subsystem based on hydrogen technologies or at the energetic system embedded components. On the basis of real measurement and its evaluation the ideal parameters of the photovoltaic field were calculated as well as the hydrogen technologies for supposed purpose and the power requirements.

  5. Surface Complexation Modelling in Metal-Mineral-Bacteria Systems

    Science.gov (United States)

    Johnson, K. J.; Fein, J. B.

    2002-12-01

    The reactive surfaces of bacteria and minerals can determine the fate, transport, and bioavailability of aqueous heavy metal cations. Geochemical models are instrumental in accurately accounting for the partitioning of the metals between mineral surfaces and bacteria cell walls. Previous research has shown that surface complexation modelling (SCM) is accurate in two-component systems (metal:mineral and metal:bacteria); however, the ability of SCMs to account for metal distribution in mixed metal-mineral-bacteria systems has not been tested. In this study, we measure aqueous Cd distributions in water-bacteria-mineral systems, and compare these observations with predicted distributions based on a surface complexation modelling approach. We measured Cd adsorption in 2- and 3-component batch adsorption experiments. In the 2-component experiments, we measured the extent of adsorption of 10 ppm aqueous Cd onto either a bacterial or hydrous ferric oxide sorbent. The metal:bacteria experiments contained 1 g/L (wet wt.) of B. subtilis, and were conducted as a function of pH; the metal:mineral experiments were conducted as a function of both pH and HFO content. Two types of 3-component Cd adsorption experiments were also conducted in which both mineral powder and bacteria were present as sorbents: 1) one in which the HFO was physically but not chemically isolated from the system using sealed dialysis tubing, and 2) others where the HFO, Cd and B. subtilis were all in physical contact. The dialysis tubing approach enabled the direct determination of the concentration of Cd on each sorbing surface, after separation and acidification of each sorbent. The experiments indicate that both bacteria and mineral surfaces can dominate adsorption in the system, depending on pH and bacteria:mineral ratio. The stability constants, determined using the data from the 2-component systems, along with those for other surface and aqueous species in the systems, were used with FITEQL to

  6. Quality assurance plan for the data acquisition and management system for monitoring the fuel oil spill at the Sandia National Laboratories installation in Livermore, California

    International Nuclear Information System (INIS)

    Peerenboom, J.P.; Leser, C.C.; Ramsey, G.M.; Widing, M.A.

    1995-04-01

    In February 1975, the accidental puncture of an underground transfer line buried about 4 ft below the ground surface at the SNL installation in Livermore, California, resulted in the release of approximately 225.5 m 3 of No. 2 diesel fuel. This report describes the formal quality assurance plan that will be used for the data acquisition and management system developed to monitor a bioremediation pilot study by Argonne National Laboratory in association with Sandia National Laboratories. The data acquisition and management system will record the site data during the bioremediation effort and assist users in site analysis. The designs of the three major subsystems of this system are described in this report. Quality assurance criteria are defined for the management, performance, and assessment of the system. Finally, the roles and responsibilities for configuration management of this system are defined for the entire life cycle of the project

  7. Active surface system for the new Sardinia Radiotelescope

    Science.gov (United States)

    Orfei, Alessandro; Morsiani, Marco; Zacchiroli, Giampaolo; Maccaferri, Giuseppe; Roda, Juri; Fiocchi, Franco

    2004-09-01

    In this paper we'll describe the active surface system that will be provided on the new Italian radiotelescope being in the phase of erection in the Sardinia Island. SRT (Sardinia Radiotelescope) will be a 64m shaped dish working up to 100GHz by exploiting the active surface facility designed by the authors. This facility will overcome the effects of gravity deformations on the antenna gain and will also be used to re-shape in a parabolic form the primary mirror, in order to avoid large phase error contribution on the antenna gain for the highest frequencies placed on the primary focus. Together with the description of the SRT system, a wide overview will be given regarding our previous installation of an active surface system, that can be seen like a prototype for SRT, mounted on the 32m dish of the Noto antenna.

  8. Design and implementation of an online systemic human anatomy course with laboratory.

    Science.gov (United States)

    Attardi, Stefanie M; Rogers, Kem A

    2015-01-01

    Systemic Human Anatomy is a full credit, upper year undergraduate course with a (prosection) laboratory component at Western University Canada. To meet enrollment demands beyond the physical space of the laboratory facility, a fully online section was developed to run concurrently with the traditional face to face (F2F) course. Lectures given to F2F students are simultaneously broadcasted to online students using collaborative software (Blackboard Collaborate). The same collaborative software is used by a teaching assistant to deliver laboratory demonstrations in which three-dimensional (3D) virtual anatomical models are manipulated. Ten commercial software programs were reviewed to determine their suitability for demonstrating the virtual models, resulting in the selection of Netter's 3D Interactive Anatomy. Supplementary online materials for the central nervous system were developed by creating 360° images of plastinated prosected brain specimens and a website through which they could be accessed. This is the first description of a fully online undergraduate anatomy course with a live, interactive laboratory component. Preliminary data comparing the online and F2F student grades suggest that previous student academic performance, and not course delivery format, predicts performance in anatomy. Future qualitative studies will reveal student perceptions about their learning experiences in both of the course delivery formats. © 2014 American Association of Anatomists.

  9. Importance of implementing an analytical quality control system in a core laboratory.

    Science.gov (United States)

    Marques-Garcia, F; Garcia-Codesal, M F; Caro-Narros, M R; Contreras-SanFeliciano, T

    2015-01-01

    The aim of the clinical laboratory is to provide useful information for screening, diagnosis and monitoring of disease. The laboratory should ensure the quality of extra-analytical and analytical process, based on set criteria. To do this, it develops and implements a system of internal quality control, designed to detect errors, and compare its data with other laboratories, through external quality control. In this way it has a tool to detect the fulfillment of the objectives set, and in case of errors, allowing corrective actions to be made, and ensure the reliability of the results. This article sets out to describe the design and implementation of an internal quality control protocol, as well as its periodical assessment intervals (6 months) to determine compliance with pre-determined specifications (Stockholm Consensus(1)). A total of 40 biochemical and 15 immunochemical methods were evaluated using three different control materials. Next, a standard operation procedure was planned to develop a system of internal quality control that included calculating the error of the analytical process, setting quality specifications, and verifying compliance. The quality control data were then statistically depicted as means, standard deviations, and coefficients of variation, as well as systematic, random, and total errors. The quality specifications were then fixed and the operational rules to apply in the analytical process were calculated. Finally, our data were compared with those of other laboratories through an external quality assurance program. The development of an analytical quality control system is a highly structured process. This should be designed to detect errors that compromise the stability of the analytical process. The laboratory should review its quality indicators, systematic, random and total error at regular intervals, in order to ensure that they are meeting pre-determined specifications, and if not, apply the appropriate corrective actions

  10. Tangible display systems: bringing virtual surfaces into the real world

    Science.gov (United States)

    Ferwerda, James A.

    2012-03-01

    We are developing tangible display systems that enable natural interaction with virtual surfaces. Tangible display systems are based on modern mobile devices that incorporate electronic image displays, graphics hardware, tracking systems, and digital cameras. Custom software allows the orientation of a device and the position of the observer to be tracked in real-time. Using this information, realistic images of surfaces with complex textures and material properties illuminated by environment-mapped lighting, can be rendered to the screen at interactive rates. Tilting or moving in front of the device produces realistic changes in surface lighting and material appearance. In this way, tangible displays allow virtual surfaces to be observed and manipulated as naturally as real ones, with the added benefit that surface geometry and material properties can be modified in real-time. We demonstrate the utility of tangible display systems in four application areas: material appearance research; computer-aided appearance design; enhanced access to digital library and museum collections; and new tools for digital artists.

  11. Design demonstrations for category B tank systems at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1994-11-01

    This document presents design demonstrations conducted of liquid low-level waste (LLLW) storage tank systems located at the Oak Ridge National Laboratory (ORNL). Demonstration of the design of these tank systems has been stipulated by the Federal Facility Agreement (FFA) between the US Environmental Protection Agency (EPA)-Region IV; the Tennessee Department of Environment and Conservation (TDEC); and the DOE. The FFA establishes four categories of tanks. These are: Category A -- New or replacement tank systems with secondary containment; Category B -- Existing tank systems with secondary containment; Category C -- Existing tank systems without secondary containment; Category D -- Existing tank systems without secondary containment that are removed from service. This document provides a design demonstration of the secondary containment and ancillary equipment of 11 tank systems listed in the FFA as Category B. The design demonstration for each tank is presented

  12. Upgrading the control system for the Accelerators at the Svedberg Laboratory

    International Nuclear Information System (INIS)

    Gajewski, K.J.; Thuresson, L.; Johansson, O.

    1992-01-01

    Two accelerators at The Svedberg Laboratory in Uppsala, the Gustaf Werner cyclotron and the CELSIUS ring, will get a new control system. At present both the cyclotron and the ring have their own control systems based on S99 and PDP-11 minicomputers respectively. There are also a number of subsystems which are controlled separately from the stand-alone PC based consoles (ECR ion source, electron cooler, vacuum system). The goal of the rejuvenation is to integrate all existing control systems and provide the new system with an uniform operators interface based on workstations. The obsolete S99 microcomputers will be substituted with a VME system and all subsystems will be connected to the Ethernet. The upgrade strategy enabling the transformation of the system without any long shut-down period is discussed. Hardware and software planned for the upgrade is presented together with a discussion of expected problems. (author)

  13. Design demonstrations for category B tank systems at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    1994-11-01

    This document presents design demonstrations conducted of liquid low-level waste (LLLW) storage tank systems located at the Oak Ridge National Laboratory (ORNL). Demonstration of the design of these tank systems has been stipulated by the Federal Facility Agreement (FFA) between the US Environmental Protection Agency (EPA)-Region IV; the Tennessee Department of Environment and Conservation (TDEC); and the DOE. The FFA establishes four categories of tanks. These are: Category A -- New or replacement tank systems with secondary containment; Category B -- Existing tank systems with secondary containment; Category C -- Existing tank systems without secondary containment; Category D -- Existing tank systems without secondary containment that are removed from service. This document provides a design demonstration of the secondary containment and ancillary equipment of 11 tank systems listed in the FFA as Category B. The design demonstration for each tank is presented.

  14. Mechanical support and transport system used for the neutrino horn system at Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Walker, J.C.; Carroll, A.S.; Leonhardt, W.

    1987-01-01

    The study of neutrinos at the Alternating Gradient Synchrotron (AGS), Brookhaven National Laboratory (BNL), requires hardware for their initiation and control. The basics consist of a target, two horns and three collimators. This paper describes the installation, support and positioning of these components within a settling concrete blockhouse

  15. Use of artificial intelligence in analytical systems for the clinical laboratory.

    Science.gov (United States)

    Place, J F; Truchaud, A; Ozawa, K; Pardue, H; Schnipelsky, P

    1995-01-01

    The incorporation of information-processing technology into analytical systems in the form of standard computing software has recently been advanced by the introduction of artificial intelligence (AI), both as expert systems and as neural networks.This paper considers the role of software in system operation, control and automation, and attempts to define intelligence. AI is characterized by its ability to deal with incomplete and imprecise information and to accumulate knowledge. Expert systems, building on standard computing techniques, depend heavily on the domain experts and knowledge engineers that have programmed them to represent the real world. Neural networks are intended to emulate the pattern-recognition and parallel processing capabilities of the human brain and are taught rather than programmed. The future may lie in a combination of the recognition ability of the neural network and the rationalization capability of the expert system.In the second part of the paper, examples are given of applications of AI in stand-alone systems for knowledge engineering and medical diagnosis and in embedded systems for failure detection, image analysis, user interfacing, natural language processing, robotics and machine learning, as related to clinical laboratories.It is concluded that AI constitutes a collective form of intellectual propery, and that there is a need for better documentation, evaluation and regulation of the systems already being used in clinical laboratories.

  16. Survey of biomedical and environental data bases, models, and integrated computer systems at Argonne National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Murarka, I.P.; Bodeau, D.J.; Scott, J.M.; Huebner, R.H.

    1978-08-01

    This document contains an inventory (index) of information resources pertaining to biomedical and environmental projects at Argonne National Laboratory--the information resources include a data base, model, or integrated computer system. Entries are categorized as models, numeric data bases, bibliographic data bases, or integrated hardware/software systems. Descriptions of the Information Coordination Focal Point (ICFP) program, the system for compiling this inventory, and the plans for continuing and expanding it are given, and suggestions for utilizing the services of the ICFP are outlined.

  17. Survey of biomedical and environental data bases, models, and integrated computer systems at Argonne National Laboratory

    International Nuclear Information System (INIS)

    Murarka, I.P.; Bodeau, D.J.; Scott, J.M.; Huebner, R.H.

    1978-08-01

    This document contains an inventory (index) of information resources pertaining to biomedical and environmental projects at Argonne National Laboratory--the information resources include a data base, model, or integrated computer system. Entries are categorized as models, numeric data bases, bibliographic data bases, or integrated hardware/software systems. Descriptions of the Information Coordination Focal Point (ICFP) program, the system for compiling this inventory, and the plans for continuing and expanding it are given, and suggestions for utilizing the services of the ICFP are outlined

  18. Development of waste chargeback systems at the Idaho National Engineering Laboratory (INEL)

    International Nuclear Information System (INIS)

    Piscitella, R.R.

    1996-02-01

    Chargeback systems have been discussed (and cussed), tried, modified, and in some cases, successfully implemented in the DOE complex over the years. With the current emphasis on ''Doing business like a private company,'' there has been renewed interest at the Idaho National Engineering Laboratory (INEL) in implementing chargeback systems for waste management activities. The most recent activities relating to chargeback at the INEL started the summer of 1995 with direction from waste operations management to develop and pilot test a chargeback system. This paper presents the results of this effort to date

  19. Oceanographic and surface meteorological data collected from Gibraltar Island Station by Ohio State University; Stone Laboratory and assembled by Great Lakes Observing System (GLOS) in the Great Lakes region from 2015-05-26 to 2017-08-31 (NCEI Accession 0130545)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NCEI Accession 0130545 contains oceanographic and surface meteorological data in netCDF formatted files, which follow the Climate and Forecast metadata convention...

  20. Oceanographic and surface meteorological data collected from station Middle Bay Light, AL by Dauphin Island Sea Laboratory (DISL) and assembled by Gulf of Mexico Coastal Ocean Observing System (GCOOS) in the Coastal waters of Alabama and Gulf of Mexico from 2008-01-01 to 2017-05-03 (NCEI Accession 0163754)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NCEI Accession 0163754 contains oceanographic and surface meteorological data in netCDF formatted files, which follow the Climate and Forecast metadata convention...

  1. Oceanographic and surface meteorological data collected from station Cedar Point, AL by Dauphin Island Sea Laboratory (DISL) and assembled by Gulf of Mexico Coastal Ocean Observing System (GCOOS) in the Coastal waters of Alabama and Gulf of Mexico from 2008-04-03 to 2017-04-30 (NCEI Accession 0163213)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NCEI Accession 0163213 contains oceanographic and surface meteorological data in netCDF formatted files, which follow the Climate and Forecast metadata convention...

  2. Oceanographic and surface meteorological data collected from station Perdido Pass, AL by Dauphin Island Sea Laboratory (DISL) and assembled by Gulf of Mexico Coastal Ocean Observing System (GCOOS) in the Coastal waters of Alabama and Gulf of Mexico from 2011-11-07 to 2017-04-30 (NCEI Accession 0163767)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NCEI Accession 0163767 contains oceanographic and surface meteorological data in netCDF formatted files, which follow the Climate and Forecast metadata convention...

  3. Oceanographic and surface meteorological data collected from station RECON Michigan, Muskegon, by Great Lakes Environmental Research Laboratory and assembled by Great Lakes Observing System (GLOS) in the Great Lakes region from 2014-07-23 to 2017-08-31 (NODC Accession 0123651)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NCEI Accession 0123651 contains oceanographic and surface meteorological data in netCDF formatted files, which follow the Climate and Forecast metadata convention...

  4. Oceanographic and surface meteorological data collected from University of Michigan Marine Hydrodynamics Laboratories Bio Buoy by University of Michigan and assembled by Great Lakes Observing System (GLOS) in the Great Lakes region from 2014-07-01 to 2017-08-31 (NODC Accession 0123645)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NCEI Accession 0123645 contains oceanographic and surface meteorological data in netCDF formatted files, which follow the Climate and Forecast metadata convention...

  5. Oceanographic and surface meteorological data collected from University of Michigan Marine Hydrodynamics Laboratories Bio Buoy by University of Michigan and assembled by Great Lakes Observing System (GLOS) in the Great Lakes region from 2014-07-01 to 2017-08-31 (NCEI Accession 0123660)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NCEI Accession 0123660 contains oceanographic and surface meteorological data in netCDF formatted files, which follow the Climate and Forecast metadata convention...

  6. Oceanographic and surface meteorological data collected from station Dauphin Island, AL by Dauphin Island Sea Laboratory (DISL) and assembled by Gulf of Mexico Coastal Ocean Observing System (GCOOS) in the Coastal waters of Alabama and Gulf of Mexico from 2008-01-01 to 2017-04-30 (NCEI Accession 0163672)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NCEI Accession 0163672 contains oceanographic and surface meteorological data in netCDF formatted files, which follow the Climate and Forecast metadata convention...

  7. Oceanographic and surface meteorological data collected from station Bon Secour, LA by Dauphin Island Sea Laboratory (DISL) and assembled by Gulf of Mexico Coastal Ocean Observing System (GCOOS) in the Coastal waters of Alabama and Gulf of Mexico from 2011-01-01 to 2017-05-02 (NCEI Accession 0163204)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NCEI Accession 0163204 contains oceanographic and surface meteorological data in netCDF formatted files, which follow the Climate and Forecast metadata convention...

  8. Oceanographic and surface meteorological data collected from station Katrina Cut, AL by Dauphin Island Sea Laboratory (DISL) and assembled by Gulf of Mexico Coastal Ocean Observing System (GCOOS) in the Coastal waters of Alabama and Gulf of Mexico from 2011-04-15 to 2017-05-04 (NCEI Accession 0163673)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NCEI Accession 0163673 contains oceanographic and surface meteorological data in netCDF formatted files, which follow the Climate and Forecast metadata convention...

  9. Oceanographic and surface meteorological data collected from station Meaher Park, AL by Dauphin Island Sea Laboratory (DISL) and assembled by Gulf of Mexico Coastal Ocean Observing System (GCOOS) in the Coastal waters of Alabama and Gulf of Mexico from 2008-01-01 to 2017-05-04 (NCEI Accession 0163755)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NCEI Accession 0163755 contains oceanographic and surface meteorological data in netCDF formatted files, which follow the Climate and Forecast metadata convention...

  10. Establishing Ebola Virus Disease (EVD) diagnostics using GeneXpert technology at a mobile laboratory in Liberia: Impact on outbreak response, case management and laboratory systems strengthening.

    Science.gov (United States)

    Raftery, Philomena; Condell, Orla; Wasunna, Christine; Kpaka, Jonathan; Zwizwai, Ruth; Nuha, Mahmood; Fallah, Mosoka; Freeman, Maxwell; Harris, Victoria; Miller, Mark; Baller, April; Massaquoi, Moses; Katawera, Victoria; Saindon, John; Bemah, Philip; Hamblion, Esther; Castle, Evelyn; Williams, Desmond; Gasasira, Alex; Nyenswah, Tolbert

    2018-01-01

    The 2014-16 Ebola Virus Disease (EVD) outbreak in West Africa highlighted the necessity for readily available, accurate and rapid diagnostics. The magnitude of the outbreak and the re-emergence of clusters of EVD cases following the declaration of interrupted transmission in Liberia, reinforced the need for sustained diagnostics to support surveillance and emergency preparedness. We describe implementation of the Xpert Ebola Assay, a rapid molecular diagnostic test run on the GeneXpert platform, at a mobile laboratory in Liberia and the subsequent impact on EVD outbreak response, case management and laboratory system strengthening. During the period of operation, site coordination, management and operational capacity was supported through a successful collaboration between Ministry of Health (MoH), World Health Organization (WHO) and international partners. A team of Liberian laboratory technicians were trained to conduct EVD diagnostics and the laboratory had capacity to test 64-100 blood specimens per day. Establishment of the laboratory significantly increased the daily testing capacity for EVD in Liberia, from 180 to 250 specimens at a time when the effectiveness of the surveillance system was threatened by insufficient diagnostic capacity. During the 18 months of operation, the laboratory tested a total of 9,063 blood specimens, including 21 EVD positives from six confirmed cases during two outbreaks. Following clearance of the significant backlog of untested EVD specimens in November 2015, a new cluster of EVD cases was detected at the laboratory. Collaboration between surveillance and laboratory coordination teams during this and a later outbreak in March 2016, facilitated timely and targeted response interventions. Specimens taken from cases during both outbreaks were analysed at the laboratory with results informing clinical management of patients and discharge decisions. The GeneXpert platform is easy to use, has relatively low running costs and can be

  11. Establishing Ebola Virus Disease (EVD) diagnostics using GeneXpert technology at a mobile laboratory in Liberia: Impact on outbreak response, case management and laboratory systems strengthening

    Science.gov (United States)

    Condell, Orla; Wasunna, Christine; Kpaka, Jonathan; Zwizwai, Ruth; Nuha, Mahmood; Fallah, Mosoka; Freeman, Maxwell; Harris, Victoria; Miller, Mark; Baller, April; Massaquoi, Moses; Katawera, Victoria; Saindon, John; Bemah, Philip; Hamblion, Esther; Castle, Evelyn; Williams, Desmond; Gasasira, Alex; Nyenswah, Tolbert

    2018-01-01

    The 2014–16 Ebola Virus Disease (EVD) outbreak in West Africa highlighted the necessity for readily available, accurate and rapid diagnostics. The magnitude of the outbreak and the re-emergence of clusters of EVD cases following the declaration of interrupted transmission in Liberia, reinforced the need for sustained diagnostics to support surveillance and emergency preparedness. We describe implementation of the Xpert Ebola Assay, a rapid molecular diagnostic test run on the GeneXpert platform, at a mobile laboratory in Liberia and the subsequent impact on EVD outbreak response, case management and laboratory system strengthening. During the period of operation, site coordination, management and operational capacity was supported through a successful collaboration between Ministry of Health (MoH), World Health Organization (WHO) and international partners. A team of Liberian laboratory technicians were trained to conduct EVD diagnostics and the laboratory had capacity to test 64–100 blood specimens per day. Establishment of the laboratory significantly increased the daily testing capacity for EVD in Liberia, from 180 to 250 specimens at a time when the effectiveness of the surveillance system was threatened by insufficient diagnostic capacity. During the 18 months of operation, the laboratory tested a total of 9,063 blood specimens, including 21 EVD positives from six confirmed cases during two outbreaks. Following clearance of the significant backlog of untested EVD specimens in November 2015, a new cluster of EVD cases was detected at the laboratory. Collaboration between surveillance and laboratory coordination teams during this and a later outbreak in March 2016, facilitated timely and targeted response interventions. Specimens taken from cases during both outbreaks were analysed at the laboratory with results informing clinical management of patients and discharge decisions. The GeneXpert platform is easy to use, has relatively low running costs and can

  12. Using surfaces and surface relations in an early cognitive vision system

    DEFF Research Database (Denmark)

    Kraft, Dirk; Mustafa, Wail; Popovic, Mila

    2015-01-01

    We present a deep hierarchical visual system with two parallel hierarchies for edge and surface information. In the two hierarchies, complementary visual information is represented on different levels of granularity together with the associated uncertainties and confidences. At all levels geometr...

  13. Selective interaction of heparin with the variable region 3 within surface glycoprotein of laboratory-adapted feline immunodeficiency virus.

    Science.gov (United States)

    Hu, Qiong-Ying; Fink, Elizabeth; Grant, Chris K; Elder, John H

    2014-01-01

    Heparan sulfate proteoglycans (HSPG) can act as binding receptors for certain laboratory-adapted (TCA) strains of feline immunodeficiency virus (FIV) and human immunodeficiency virus (HIV). Heparin, a soluble heparin sulfate (HS), can inhibit TCA HIV and FIV entry mediated by HSPG interaction in vitro. In the present study, we further determined the selective interaction of heparin with the V3 loop of TCA of FIV. Our current results indicate that heparin selectively inhibits infection by TCA strains, but not for field isolates (FS). Heparin also specifically interferes with TCA surface glycoprotein (SU) binding to CXCR4, by interactions with HSPG binding sites on the V3 loop of the FIV envelope protein. Peptides representing either the N- or C-terminal side of the V3 loop and containing HSPG binding sites were able to compete away the heparin block of TCA SU binding to CXCR4. Heparin does not interfere with the interaction of SU with anti-V3 antibodies that target the CXCR4 binding region or with the interaction between FS FIV and anti-V3 antibodies since FS SU has no HSPG binding sites within the HSPG binding region. Our data show that heparin blocks TCA FIV infection or entry not only through its competition of HSPG on the cell surface interaction with SU, but also by its interference with CXCR4 binding to SU. These studies aid in the design and development of heparin derivatives or analogues that can inhibit steps in virus infection and are informative regarding the HSPG/SU interaction.

  14. Selective interaction of heparin with the variable region 3 within surface glycoprotein of laboratory-adapted feline immunodeficiency virus.

    Directory of Open Access Journals (Sweden)

    Qiong-Ying Hu

    Full Text Available Heparan sulfate proteoglycans (HSPG can act as binding receptors for certain laboratory-adapted (TCA strains of feline immunodeficiency virus (FIV and human immunodeficiency virus (HIV. Heparin, a soluble heparin sulfate (HS, can inhibit TCA HIV and FIV entry mediated by HSPG interaction in vitro. In the present study, we further determined the selective interaction of heparin with the V3 loop of TCA of FIV. Our current results indicate that heparin selectively inhibits infection by TCA strains, but not for field isolates (FS. Heparin also specifically interferes with TCA surface glycoprotein (SU binding to CXCR4, by interactions with HSPG binding sites on the V3 loop of the FIV envelope protein. Peptides representing either the N- or C-terminal side of the V3 loop and containing HSPG binding sites were able to compete away the heparin block of TCA SU binding to CXCR4. Heparin does not interfere with the interaction of SU with anti-V3 antibodies that target the CXCR4 binding region or with the interaction between FS FIV and anti-V3 antibodies since FS SU has no HSPG binding sites within the HSPG binding region. Our data show that heparin blocks TCA FIV infection or entry not only through its competition of HSPG on the cell surface interaction with SU, but also by its interference with CXCR4 binding to SU. These studies aid in the design and development of heparin derivatives or analogues that can inhibit steps in virus infection and are informative regarding the HSPG/SU interaction.

  15. ESTABLISHMENT OF AN ENVIRONMENTAL CONTROL TECHNOLOGY LABORATORY WITH A CIRCULATING FLUIDIZED-BED COMBUSTION SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Wei-Ping Pan; Andy Wu; John T. Riley

    2004-10-30

    This report is to present the progress made on the project ''Establishment of an Environmental Control Technology Laboratory (ECTL) with a Circulating Fluidized-Bed Combustion (CFBC) System'' during the period July 1, 2004 through September 30, 2004. The following tasks have been completed. First, renovation of the new Combustion Laboratory and the construction of the Circulating Fluidized-Bed (CFB) Combustor Building have started. Second, the design if the component parts of the CFBC system have been reviewed and finalized so that the drawings may be released to the manufacturers during the next quarter. Third, the experiments for solid waste (chicken litter) incineration have been conducted using a Thermogravimetric Analyzer (TGA). This is in preparation for testing in the simulated fluidized-bed combustor. The experimental results from this study are presented in this report. Finally, the proposed work for the next quarter has been outlined in this report.

  16. Idaho National Laboratory Integrated Safety Management System 2011 Effectiveness Review and Declaration Report

    Energy Technology Data Exchange (ETDEWEB)

    Farren Hunt

    2011-12-01

    Idaho National Laboratory (INL) performed an annual Integrated Safety Management System (ISMS) effectiveness review per 48 Code of Federal Regulations (CFR) 970.5223-1, 'Integration of Environment, Safety and Health into Work Planning and Execution.' The annual review assessed Integrated Safety Management (ISM) effectiveness, provided feedback to maintain system integrity, and helped identify target areas for focused improvements and assessments for fiscal year (FY) 2012. The information presented in this review of FY 2011 shows that the INL has performed many corrective actions and improvement activities, which are starting to show some of the desired results. These corrective actions and improvement activities will continue to help change culture that will lead to better implementation of defined programs, resulting in moving the Laboratory's performance from the categorization of 'Needs Improvement' to the desired results of 'Effective Performance.'

  17. Infrastructure Operations Technical Baseline Development at the Idaho National Engineering and Environmental Laboratory Using Systems Engineering

    International Nuclear Information System (INIS)

    Caliva, R.M.

    1999-01-01

    The Idaho National Engineering and Environmental Laboratory (INEEL) is a Department of Energy (DOE) national laboratory that has been performing environmental cleanup and stabilization, which was accelerated upon the end of the cold war. In fact, the INEEL currently receives two-thirds of its scope to perform these functions. These activities can only be successful, however, if infrastructure operations are adequate and appropriately tailored. Several of the systems engineers supporting a group called Environmental Management Integration (EMI) were given the charter to develop the technical baseline for all INEEL infrastructure operations. This paper will discuss the systems engineering process developed in order to capture the driving requirements and identify the necessary functions that must exist in order to successfully support environmental cleanup and stabilization

  18. Laboratory and field evaluation of a biological monitoring system using Corbicula fluminea and Mulinia lateralis

    Energy Technology Data Exchange (ETDEWEB)

    Waller, W.T.; Allen, H.J.; Schwalm, F.U.; Acevedo, M.F.; Ammann, L.P.; Dickson, K.L.; Kennedy, J.H. [Univ. of North Texas, Denton, TX (United States); Morgan, E.L. [Tennessee Technological Univ., Cookeville, TN (United States)

    1995-12-31

    Laboratory and field experiments have been performed to evaluate a non-invasive biomonitoring system using the Asiatic clam Corbicula fluminea and Mulinia lateralis. C. fluminea was exposed to simulated episodic toxicity events in the laboratory using copper, diazinon, and regulated flow rates. Group behavior during these simulated events was compared to behavior during unstressed periods to develop a statistical model and an alarm criteria. Bayou Chico, Pensacola Bay, FL, was the site for field experiments in which M. lateralis was placed in situ to evaluate the performance of the biomonitoring system. The biomonitoring system consists of proximity sensors which detect an aluminum foil target attached to the valve of an organism. Valve movements of the clams are then digitally recorded using a personal computer. Data collected from remote sites are telemetered to the lab using short wave radio. In its final form, the authors envision an in situ biological monitoring system using bivalves deployed in aquatic systems in conjunction with automated monitoring systems like those found at USGS gauging stations. A tool such as this could be used as a warning system to increase the probability of detecting toxic events as they occur.

  19. Development of a document management system for the standardization of clinical laboratory documents.

    Science.gov (United States)

    Hwang, Sang-Hyun; Jung, Seon-Kyung; Kang, Soo-Jin; Cha, Hyo Soung; Chung, Seung Hyun; Lee, Do-Hoon

    2013-11-01

    Documentation is very important; a considerable number of documents exist for use in accreditation inspection. However, most laboratories do not effectively manage the processes of documentation, organization, and storage. The purpose of this study was to facilitate the establishment of a strategically effective and sustainably standardized document management system. A document code formatting system was modified by comparing the document list data received from 3 major university hospitals. In addition, a questionnaire regarding document code standardization was created and sent to 268 institutes to establish document classifications and generate a standard coding scheme. A computerized document management system was developed. Only 32% (8 out of 25 institutes) answered that they were able to identify all of the document types and their numbers. In total, 76% of institutes (19 out of 25) answered that a systematic document management system was necessary. Disorganized document files were systemized by classifying them into 8 major groups according to their characteristics: patient test records (T), test quality control (Q), manuals (M), equipment and environment management (E), statistics (S), division administration (A), department administration (R), and others (X). Our documentation system may serve as a basis for the standardization of documents and the creation of a document management system for all hospital laboratories.

  20. Laboratory tests in support of the MSRE reactive gas removal system

    International Nuclear Information System (INIS)

    Rudolph, J.C.; Del Cul, G.D.; Caja, J.; Toth, L.M.; Williams, D.F.; Thomas, K.S.; Clark, D.E.

    1997-07-01

    The Molten Salt Reactor Experiment (MSRE) at Oak Ridge National Laboratory has been shut down since December 1969, at which time the molten salt mixture of LiF-BeF 2 -ZrF 4 - 233 UF 4 (64.5-30.3-5.0-0.13 mol%) was transferred to fuel salt drain tanks for storage. In the late 1980s, increased radiation in one of the gas lines from the drain tank was attributed to 233 UF 6 . In 1994 two gas samples were withdraw (from a gas line in the Vent House connecting to the drain tanks) and analyzed. Surprisingly, 350 mm Hg of F 2 , 70 mm Hg of UF 6 , and smaller amounts of other gases were found in both of the samples. To remote this gas from above the drain tanks and all of the associated piping, the reactive gas removal system (RGRS) was designed. This report details the laboratory testing of the RGRS, using natural uranium, prior to its implementation at the MSRE facility. The testing was performed to ensure that the equipment functioned properly and was sufficient to perform the task while minimizing exposure to personnel. In addition, the laboratory work provided the research and development effort necessary to maximize the performance of the system. Throughout this work technicians and staff who were to be involved in RGRS operation at the MSRE site worked directly with the research staff in completing the laboratory testing phase. Consequently, at the end of the laboratory work, the personnel who were to be involved in the actual operations had acquired all of the training and experience necessary to continue with the process of reactive gas removal

  1. QUALITY MANAGEMENT SYSTEM IN CLINICAL LABORATORIES ACCORDING TO THE ISO 15189:2007 STANDARD - EVALUATION OF THE BENEFITS OF IMPLEMENTATION IN AN ASSISTED REPRODUCTION LABORATORY

    Directory of Open Access Journals (Sweden)

    A.D. Sialakouma

    2011-03-01

    Full Text Available Biomedical science is a sensitive discipline and presents unique challenges due to its social character, continuous development and competitiveness. The issue of quality management systems and accreditation is gaining increasing interest in this sector. All over Europe, Health Services Units have started to introduce quality management systems and harmonization of criteria for accreditation is of increasing importance. Moreover, clinical laboratories, like the Assisted Reproduction laboratories and biochemical laboratories are required to apply a Quality Management System in order to ensure their correct, scientific and effective operation. Ultimately, it is a moral obligation for every health care organisation to supply the best possible care for the patient. The specific features and the diversity of clinical laboratories led to the introduction (2003 and, recently to the revision (2007 of the international standard ISO 15189, which is the first international standard developed specifically to address the requirements for accreditation of this type of laboratory. The basic principles for the quality assurance in the clinical laboratories are: x Complete and unambiguous standardized operating procedures. x Complete and unambiguous directives of operation. x Obligatory detailed written documentation, i.e., how each action is done, who will do it, where will this action take place and when. x Suitable scheduling of calibration/control/preventive maintenance of laboratory equipment and recording of each activity. x Distribution of responsibilities among the staff and continuous education and briefing according to current scientific data. x Complete and informed record file keeping. x Continuous improvement which is monitored with the adoption of quantified indicators. x Internal and external audit of all activities. x Troubleshooting. All these principles should be supported by the Management in order that the necessary adaptations should be made

  2. An Approach to Laboratory Cost Containment Using a Data Base Management System

    OpenAIRE

    Kaplan, E.; Boeckmann, A.; Sheiner, L.B.

    1981-01-01

    Numerous articles have emphasized the need to develop effective cost containment strategies for laboratory utilization. This paper discusses the construction and use of a prototype data base system to detect and verify the existence of conditionally useless tests, or CUTs. For the purposes of this paper, a conditionally useless test is defined to be a test which, under certain conditions, does not provide sufficient new or relevant information to offset its associated cost.

  3. Results from laboratory tests of the two-dimensional Time-Encoded Imaging System.

    Energy Technology Data Exchange (ETDEWEB)

    Marleau, Peter; Brennan, James S.; Brubaker, Erik; Gerling, Mark D; Le Galloudec, Nathalie Joelle

    2014-09-01

    A series of laboratory experiments were undertaken to demonstrate the feasibility of two dimensional time-encoded imaging. A prototype two-dimensional time encoded imaging system was designed and constructed. Results from imaging measurements of single and multiple point sources as well as extended source distributions are presented. Time encoded imaging has proven to be a simple method for achieving high resolution two-dimensional imaging with potential to be used in future arms control and treaty verification applications.

  4. Evaluation of potential surface rupture and review of current seismic hazards program at the Los Alamos National Laboratory. Final report

    International Nuclear Information System (INIS)

    1991-01-01

    This report summarizes the authors review and evaluation of the existing seismic hazards program at Los Alamos National Laboratory (LANL). The report recommends that the original program be augmented with a probabilistic analysis of seismic hazards involving assignment of weighted probabilities of occurrence to all potential sources. This approach yields a more realistic evaluation of the likelihood of large earthquake occurrence particularly in regions where seismic sources may have recurrent intervals of several thousand years or more. The report reviews the locations and geomorphic expressions of identified fault lines along with the known displacements of these faults and last know occurrence of seismic activity. Faults are mapped and categorized into by their potential for actual movement. Based on geologic site characterization, recommendations are made for increased seismic monitoring; age-dating studies of faults and geomorphic features; increased use of remote sensing and aerial photography for surface mapping of faults; the development of a landslide susceptibility map; and to develop seismic design standards for all existing and proposed facilities at LANL

  5. LiLa Booking System: Architecture and Conceptual Model of a Rig Booking System for On-Line Laboratories

    Directory of Open Access Journals (Sweden)

    Dr. Víctor A. Villagrá

    2011-11-01

    Full Text Available Many educational institutions acknowledged the importance of providing online-access to student laboratories. To optimize the use of the scarce and expensive resources such laboratories depend on, it is advisable to establish and setup a booking system that helps to administer access to them. This paper reports on the architecture and conceptual model of the rig booking system designed for the LiLa Portal, a web portal that makes virtual and remote experiments available on the Internet. The design of the booking system is based on a requirements analysis carried out by the EC funded LiLa project in cooperation with international partners from the Global Online Lab Consortium, GoLC.

  6. An exploratory investigation of the translation of Pacific Northwest Laboratory`s print manuals system to an on-line manuals system

    Energy Technology Data Exchange (ETDEWEB)

    Heubach, J.G.; Hunt, S.T.; Pond, L.R.

    1992-06-01

    Information management technology has proliferated in the past decade in response to the information explosion. As documentation accumulates, the need to access information residing in manuals, handbooks and regulations conveniently, accurately, and quickly has increased. However, studies show that only fractions of the available information is read (Martin, 1978). Consequently, one of the biggest challenges in linking information and electronic management of information is to use the power of communication technology to meet the information needs of the audience. Pacific Northwest Laboratories` (PNL) investigation of translating its print manual system to an on-line system fits this challenge precisely. PNL`s manuals contain a tremendous amount of information for which manual holders are responsible. To perform their tasks in compliance with policy and procedure guidelines, users need to access information accurately, conveniently, and quickly. In order to select and use information management tools wisely, answers must be sought to a few basic questions. Communication experts cite four key questions: What do users want? What do users need? What characteristics of an on-line information system affect its usefulness? Who are the users whose wants and needs are to be met? Once these questions are answered, attention can be focused on finding the best match between user requirements and technology characteristics and weighing the costs and benefits of proposed options.

  7. Experimental study of wireless part of laboratory bench, implementing IR-UWB radio-over-fiber system

    Science.gov (United States)

    Meshkov, Ivan K.; Sultanov, Albert Kh.; Vinogradova, Irina L.; Grakhova, Elizaveta P.; Abdrakhmanova, Guzel I.; Andrianova, Anna V.; Ishmyarov, Arsen A.; Voronkov, Grigory S.

    2017-04-01

    Wireless part of the laboratory bench, implementing IR-UWB Radio-over-Fiber system, is described in the paper. Experimental prototype of fractal antenna radiating system (FARS) is considered, various transmission modes of the laboratory bench, which allow to investigate technical specifications, are described. Research results are presented and analyzed.

  8. Integrating Environmental Management in Chemical Engineering Education by Introducing an Environmental Management System in the Student's Laboratory

    Science.gov (United States)

    Montanes, Maria T.; Palomares, Antonio E.

    2008-01-01

    In this work we show how specific challenges related to sustainable development can be integrated into chemical engineering education by introducing an environmental management system in the laboratory where the students perform their experimental lessons. It is shown how the system has been developed and implemented in the laboratory, what role…

  9. Role of WhatsApp Messenger in the Laboratory Management System: A Boon to Communication.

    Science.gov (United States)

    Dorwal, Pranav; Sachdev, Ritesh; Gautam, Dheeraj; Jain, Dharmendra; Sharma, Pooja; Tiwari, Assem Kumar; Raina, Vimarsh

    2016-01-01

    The revolution of internet and specifically mobile internet has occurred at a blinding pace over the last decade. With the advent of smart phones, the hand held device has become much more than a medium of voice calling. Healthcare has been catching up with the digital revolution in the form of Hospital Information System and Laboratory Information System. However, the advent of instant messaging services, which are abundantly used by the youth, can be used to improve communication and coordination among the various stake holders in the healthcare sector. We have tried to look at the impact of using the WhatsApp messenger service in the laboratory management system, by forming multiple groups of the various subsections of the laboratory. A total of 35 members used this service for a period of 3 months and their response was taken on a scale of 1 to 10. There was significant improvement in the communication in the form of sharing photographic evidence, information about accidents, critical alerts, duty rosters, academic activities and getting directives from seniors. There was also some increase in the load of adding information to the application and disturbance in the routine activities; but the benefits far outweighed the minor hassles. We thereby suggest and foresee another communication revolution which will change the way information is shared in a healthcare sector, with hospital specific dedicated apps.

  10. ESTABLISHMENT OF AN ENVIRONMENTAL CONTROL TECHNOLOGY LABORATORY WITH A CIRCULATING FLUIDIZED-BED COMBUSTION SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Wei-Ping Pan; Andy Wu; John T. Riley

    2005-07-30

    This purpose of this report is to present the progress made on the project ''Establishment of an Environmental Control Technology Laboratory (ECTL) with a Circulating Fluidized-Bed Combustion (CFBC) System'' during the period April 1, 2005 through June 30, 2005. The following tasks have been completed. First, the new Combustion Laboratory was occupied on June 15, 2005, and the construction of the Circulating Fluidized-Bed (CFB) Combustor Building is in the final painting stage. Second, the fabrication and manufacturing contract for the CFBC Facility was awarded to Sterling Boiler & Mechanical, Inc. of Evansville, Indiana. Sterling is manufacturing the assembly and component parts of the CFBC system. The erection of the CFBC system is expected to start September 1, 2005. Third, mercury emissions from the cofiring of coal and chicken waste was studied experimentally in the laboratory-scale simulated fluidized-bed combustion facility. The experimental results from this study are presented in this report. Finally, the proposed work for the next quarter is described.

  11. Laboratory information management system for membrane protein structure initiative--from gene to crystal.

    Science.gov (United States)

    Troshin, Petr V; Morris, Chris; Prince, Stephen M; Papiz, Miroslav Z

    2008-12-01

    Membrane Protein Structure Initiative (MPSI) exploits laboratory competencies to work collaboratively and distribute work among the different sites. This is possible as protein structure determination requires a series of steps, starting with target selection, through cloning, expression, purification, crystallization and finally structure determination. Distributed sites create a unique set of challenges for integrating and passing on information on the progress of targets. This role is played by the Protein Information Management System (PIMS), which is a laboratory information management system (LIMS), serving as a hub for MPSI, allowing collaborative structural proteomics to be carried out in a distributed fashion. It holds key information on the progress of cloning, expression, purification and crystallization of proteins. PIMS is employed to track the status of protein targets and to manage constructs, primers, experiments, protocols, sample locations and their detailed histories: thus playing a key role in MPSI data exchange. It also serves as the centre of a federation of interoperable information resources such as local laboratory information systems and international archival resources, like PDB or NCBI. During the challenging task of PIMS integration, within the MPSI, we discovered a number of prerequisites for successful PIMS integration. In this article we share our experiences and provide invaluable insights into the process of LIMS adaptation. This information should be of interest to partners who are thinking about using LIMS as a data centre for their collaborative efforts.

  12. Reference Reactor Module for the Affordable Fission Surface Power System

    International Nuclear Information System (INIS)

    Poston, David I.; Kapernick, Richard J.; Dixon, David D.; Amiri, Benjamin W.; Marcille, Thomas F.

    2008-01-01

    Surface fission power systems on the Moon and Mars may provide the first US application of fission reactor technology in space since 1965. The requirements of many surface power applications allow the consideration of systems with much less development risk than most other space reactor applications, because of modest power (10s of kWe) and no driving need for minimal mass (allowing temperatures 2 -fueled, liquid metal-cooled fission reactor coupled to free-piston Stirling converters. The reactor shielding approach utilizes both in-situ and launched shielding to keep the dose to astronauts much lower than the natural background radiation on the lunar surface. One of the important 'affordability' attributes is that the concept has been designed to minimize both the technical and programmatic safety risk

  13. Application of MIMO Techniques in sky-surface wave hybrid networking sea-state radar system

    Science.gov (United States)

    Zhang, L.; Wu, X.; Yue, X.; Liu, J.; Li, C.

    2016-12-01

    The sky-surface wave hybrid networking sea-state radar system contains of the sky wave transmission stations at different sites and several surface wave radar stations. The subject comes from the national 863 High-tech Project of China. The hybrid sky-surface wave system and the HF surface wave system work simultaneously and the HF surface wave radar (HFSWR) can work in multi-static and surface-wave networking mode. Compared with the single mode radar system, this system has advantages of better detection performance at the far ranges in ocean dynamics parameters inversion. We have applied multiple-input multiple-output(MIMO) techniques in this sea-state radar system. Based on the multiple channel and non-causal transmit beam-forming techniques, the MIMO radar architecture can reduce the size of the receiving antennas and simplify antenna installation. Besides, by efficiently utilizing the system's available degrees of freedom, it can provide a feasible approach for mitigating multipath effect and Doppler-spread clutter in Over-the-horizon Radar. In this radar, slow-time phase-coded MIMO method is used. The transmitting waveforms are phase-coded in slow-time so as to be orthogonal after Doppler processing at the receiver. So the MIMO method can be easily implemented without the need to modify the receiver hardware. After the radar system design, the MIMO experiments of this system have been completed by Wuhan University during 2015 and 2016. The experiment used Wuhan multi-channel ionospheric sounding system(WMISS) as sky-wave transmitting source and three dual-frequency HFSWR developed by the Oceanography Laboratory of Wuhan University. The transmitter system located at Chongyang with five element linear equi-spaced antenna array and Wuhan with one log-periodic antenna. The RF signals are generated by synchronized, but independent digital waveform generators - providing complete flexibility in element phase and amplitude control, and waveform type and parameters

  14. Localized surface plasmon resonance mercury detection system and methods

    Science.gov (United States)

    James, Jay; Lucas, Donald; Crosby, Jeffrey Scott; Koshland, Catherine P.

    2016-03-22

    A mercury detection system that includes a flow cell having a mercury sensor, a light source and a light detector is provided. The mercury sensor includes a transparent substrate and a submonolayer of mercury absorbing nanoparticles, e.g., gold nanoparticles, on a surface of the substrate. Methods of determining whether mercury is present in a sample using the mercury sensors are also provided. The subject mercury detection systems and methods find use in a variety of different applications, including mercury detecting applications.

  15. CLASSIFICATION OF THE MGR SURFACE ENVIRONMENTAL MONITORING SYSTEM

    International Nuclear Information System (INIS)

    J.A. Ziegler

    1999-01-01

    The purpose of this analysis is to document the Quality Assurance (QA) classification of the Monitored Geologic Repository (MGR) surface environmental monitoring system structures, systems and components (SSCs) performed by the MGR Safety Assurance Department. This analysis also provides the basis for revision of YMP/90-55Q, Q-List (YMP 1998). The Q-List identifies those MGR SSCs subject to the requirements of DOE/RW-0333PY ''Quality Assurance Requirements and Description'' (QARD) (DOE 1998)

  16. In situ surface-enhanced Raman spectroelectrochemical analysis system with a hemin modified nanostructured gold surface.

    Science.gov (United States)

    Yuan, Tao; Le Thi Ngoc, Loan; van Nieuwkasteele, Jan; Odijk, Mathieu; van den Berg, Albert; Permentier, Hjalmar; Bischoff, Rainer; Carlen, Edwin T

    2015-03-03

    An integrated surface-enhanced Raman scattering (SERS) spectroelectrochemical (SEC) analysis system is presented that combines a small volume microfluidic sample chamber (Raman spectroelectrochemistry. The SEC system includes a nanostructured Au surface that serves dual roles as the electrochemical working electrode (WE) and SERS substrate, a microfabricated Pt counter electrode (CE), and an external Ag/AgCl reference electrode (RE). The nanostructured Au WE enables highly sensitive in situ SERS spectroscopy through large and reproducible SERS enhancements, which eliminates the need for resonant wavelength matching of the laser excitation source with the electronic absorption of the target molecule. The new SEC analysis system has the merits of wide applicability to target molecules, small sample volume, and a low detection limit. We demonstrate in situ SERS spectroelectrochemistry measurements of the metalloporphyrin hemin showing shifts of the iron oxidation marker band ν4 with the nanostructured Au working electrode under precise potential control.

  17. CNEA's (Comision Nacional de Energia Atomica) experience in the preparation of a national system for laboratory accreditation

    International Nuclear Information System (INIS)

    Piacquadio, N.H.; Palacios, T.A.; Casa, V.A.; Koll, J.H.

    1993-01-01

    Within the regional markets, as it is the case of MERCOSUR , the laboratories which are suppliers of test and calibration results, are mutually recognized through the National Accreditation Systems. In Argentina there is a project to create a Center for the Accreditation of Test Laboratories. CNEA, which is involved in the execution of large projects and has adopted quality assurance criteria for a long time, requires for internal and external laboratories to be qualified. At the beginning of this year, a Committee for the Qualification of Laboratories was created in the Research and Development and Fuel Cycle Areas. Its objective was planning, management of documents, coordination, evaluation and quantification of laboratories, according to national IRAM and international ISO standards. This paper analyzes the organization of the system and the methods to evaluate and qualify laboratories as a process of growing up leading to the future National Accreditation System. (author). 3 figs

  18. Establishment of an Environmental Control Technology Laboratory with a Circulating Fluidized-Bed Combustion System

    Energy Technology Data Exchange (ETDEWEB)

    Wei-Ping Pan; Yan Cao; John Smith

    2008-05-31

    On February 14, 2002, President Bush announced the Clear Skies Initiative, a legislative proposal to control the emissions of nitrogen oxides (NO{sub x}), sulfur dioxide (SO{sub 2}), and mercury from power plants. In response to this initiative, the National Energy Technology Laboratory organized a Combustion Technology University Alliance and hosted a Solid Fuel Combustion Technology Alliance Workshop. The workshop identified multi-pollutant control; improved sorbents and catalysts; mercury monitoring and capture; and improved understanding of the underlying reaction chemistry occurring during combustion as the most pressing research needs related to controlling environmental emissions from fossil-fueled power plants. The Environmental Control Technology Laboratory will help meet these challenges and offer solutions for problems associated with emissions from fossil-fueled power plants. The goal of this project was to develop the capability and technology database needed to support municipal, regional, and national electric power generating facilities to improve the efficiency of operation and solve operational and environmental problems. In order to effectively provide the scientific data and the methodologies required to address these issues, the project included the following aspects: (1) Establishing an Environmental Control Technology Laboratory using a laboratory-scale, simulated fluidized-bed combustion (FBC) system; (2) Designing, constructing, and operating a bench-scale (0.6 MW{sub th}), circulating fluidized-bed combustion (CFBC) system as the main component of the Environmental Control Technology Laboratory; (3) Developing a combustion technology for co-firing municipal solid waste (MSW), agricultural waste, and refuse-derived fuel (RDF) with high sulfur coals; (4) Developing a control strategy for gaseous emissions, including NO{sub x}, SO{sub 2}, organic compounds, and heavy metals; and (5) Developing new mercury capturing sorbents and new

  19. Determination of Surface Fluxes Using a Bowen Ratio System

    African Journals Online (AJOL)

    USER

    Abstract. Components of the surface fluxes of the energy balance equation were determined using a Campbell Bowen ratio system. The fluxes are obtained by the energy balance Bowen ratio technique, a gradient method that uses vertical gradients of temperature and vapour pressure in combination with point ...

  20. Real-Time Hardware-in-the-Loop Laboratory Testing for Multisensor Sense and Avoid Systems

    Directory of Open Access Journals (Sweden)

    Giancarmine Fasano

    2013-01-01

    Full Text Available This paper focuses on a hardware-in-the-loop facility aimed at real-time testing of architectures and algorithms of multisensor sense and avoid systems. It was developed within a research project aimed at flight demonstration of autonomous non-cooperative collision avoidance for Unmanned Aircraft Systems. In this framework, an optionally piloted Very Light Aircraft was used as experimental platform. The flight system is based on multiple-sensor data integration and it includes a Ka-band radar, four electro-optical sensors, and two dedicated processing units. The laboratory test system was developed with the primary aim of prototype validation before multi-sensor tracking and collision avoidance flight tests. System concept, hardware/software components, and operating modes are described in the paper. The facility has been built with a modular approach including both flight hardware and simulated systems and can work on the basis of experimentally tested or synthetically generated scenarios. Indeed, hybrid operating modes are also foreseen which enable performance assessment also in the case of alternative sensing architectures and flight scenarios that are hardly reproducible during flight tests. Real-time multisensor tracking results based on flight data are reported, which demonstrate reliability of the laboratory simulation while also showing the effectiveness of radar/electro-optical fusion in a non-cooperative collision avoidance architecture.

  1. Body surface mounted biomedical monitoring system using Bluetooth.

    Science.gov (United States)

    Nambu, Masayuki

    2007-01-01

    Continuous monitoring in daily life is important for the health condition control of the elderly. However, portable or wearable devices need to carry by user on their own will. On the other hand, implantation sensors are not adoptable, because of generic users dislike to insert the any object in the body for monitoring. Therefore, another monitoring system of the health condition to carry it easily is necessary. In addition, ID system is necessary even if the subject live with few families. Furthermore, every measurement system should be wireless system, because not to obstruct the daily life of the user. In this paper, we propose the monitoring system, which is mounted on the body surface. This system will not obstruct the action or behavior of user in daily life, because this system attached the body surface on the back of the user. In addition, this system has wireless communication system, using Bluetooth, and acquired data transfer to the outside of the house via the Internet.

  2. Idaho National Laboratory Integrated Safety Management System 2010 Effectiveness Review and Declaration Report

    Energy Technology Data Exchange (ETDEWEB)

    Thomas J. Haney

    2010-12-01

    Idaho National Laboratory completes an annual Integrated Safety Management System effectiveness review per 48 CFR 970.5223-1 “Integration of Environment, Safety and Health into Work Planning and Execution.” The annual review assesses ISMS effectiveness, provides feedback to maintain system integrity, and helps identify target areas for focused improvements and assessments for the following year. Using one of the three Department of Energy (DOE) descriptors in DOE M 450.4-1 regarding the state of ISMS effectiveness during Fiscal Year (FY) 2010, the information presented in this review shows that INL achieved “Effective Performance.”

  3. A VME-based data acquisition system for nuclear physics and detector laboratories

    International Nuclear Information System (INIS)

    Fan Ruirui; Liang Xiaohua; Meng Xiangcheng

    2012-01-01

    In this paper,we report a laboratory DAQ system based on VME bus, for applications in nuclear physics and the detector tests. It uses a commercial ADC card and a single board computer as a crate controller. They are based on the VME bus.The software is based on the ROOT framework. A canvas window is employed for online monitoring, and the acquired data are stored as Histograms in a ROOT file. The data acquisition speed can rea MB/s. A spectrum of 241 Am 59 keV γ-ray collected with a CdZnTe detector is shown to demonstrate the system. (authors)

  4. A new and compact system at the AMS laboratory in Bucharest

    Science.gov (United States)

    Stan-Sion, C.; Enachescu, M.; Petre, A. R.; Simion, C. A.; Calinescu, C. I.; Ghita, D. G.

    2015-10-01

    AMS research started more than 15 years ago at our National Institute for Physics and Nuclear Engineering (IFIN-HH), Bucharest. A first facility was constructed based on our multipurpose 9 MV tandem accelerator and was upgraded several times. In May 2012 a new Cockcroft Walton type 1 MV HVEE tandetron AMS system, was commissioned. Two chemistry laboratories were constructed and are routinely performing the target preparation for carbon dating and for other isotope applications such as for geology, environment physics, medicine and forensic physics. Performance parameters of the new system are shown.

  5. Efficacy of AquatainTM, a monomolecular surface film, against the malaria vectors Anopheles stephensi and An. gambiae s.s. in the laboratory

    NARCIS (Netherlands)

    Bukhari, S.T.; Knols, B.G.J.

    2009-01-01

    Monomolecular films are used for mosquito control because of their asphyxiating effect on larvae and pupae. Compared with other films, Aquatain mosquito formulation (AMFTM) has an improved spreading ability and flexibility on a water surface. In the laboratory, AMFTM showed larvicidal, pupicidal,

  6. Using Raman Spectroscopy and Surface-Enhanced Raman Scattering to Identify Colorants in Art: An Experiment for an Upper-Division Chemistry Laboratory

    Science.gov (United States)

    Mayhew, Hannah E.; Frano, Kristen A.; Svoboda, Shelley A.; Wustholz, Kristin L.

    2015-01-01

    Surface-enhanced Raman scattering (SERS) studies of art represent an attractive way to introduce undergraduate students to concepts in nanoscience, vibrational spectroscopy, and instrumental analysis. Here, we present an undergraduate analytical or physical chemistry laboratory wherein a combination of normal Raman and SERS spectroscopy is used to…

  7. Relation between laboratory test results and histological hepatitis activity in individuals positive for hepatitis B surface antigen and antibodies to hepatitis B e antigen

    NARCIS (Netherlands)

    ter Borg, F.; ten Kate, F. J.; Cuypers, H. T.; Leentvaar-Kuijpers, A.; Oosting, J.; Wertheim-van Dillen, P. M.; Honkoop, P.; Rasch, M. C.; de Man, R. A.; van Hattum, J.; Chamuleau, R. A.; Reesink, H. W.; Jones, E. A.

    1998-01-01

    BACKGROUND: Hepatitis B surface antigen (HBsAg) and antibodies to hepatitis B e antigen (anti-HBe) commonly coexist, and laboratory tests are often requested to assess histological hepatitis activity. An optimum panel of tests has not been found and the usefulness of hepatitis B virus (HBV) DNA

  8. A tide prediction and tide height control system for laboratory mesocosms

    Directory of Open Access Journals (Sweden)

    Luke P. Miller

    2015-11-01

    Full Text Available Experimental mesocosm studies of rocky shore and estuarine intertidal systems may benefit from the application of natural tide cycles to better replicate variation in immersion time, water depth, and attendant fluctuations in abiotic and edaphic conditions. Here we describe a stand-alone microcontroller tide prediction open-source software program, coupled with a mechanical tidal elevation control system, which allows continuous adjustment of aquarium water depths in synchrony with local tide cycles. We used this system to monitor the growth of Spartina foliosa marsh cordgrass and scale insect herbivores at three simulated shore elevations in laboratory mesocosms. Plant growth decreased with increasing shore elevation, while scale insect population growth on the plants was not strongly affected by immersion time. This system shows promise for a range of laboratory mesocosm studies where natural tide cycling could impact organism performance or behavior, while the tide prediction system could additionally be utilized in field experiments where treatments need to be applied at certain stages of the tide cycle.

  9. Remote Systems Experience at the Oak Ridge National Laboratory--A Summary of Lessons Learned

    Energy Technology Data Exchange (ETDEWEB)

    Noakes, Mark W [ORNL; Burgess, Thomas W [ORNL; Rowe, John C [ORNL

    2011-01-01

    Oak Ridge National Laboratory (ORNL) has a long history in the development of remote systems to support the nuclear environment. ORNL, working in conjunction with Central Research Laboratories, created what is believed to be the first microcomputer-based implementation of dual-arm master-slave remote manipulation. As part of the Consolidated Fuel Reprocessing Program, ORNL developed the dual-arm advanced servomanipulator focusing on remote maintainability for systems exposed to high radiation fields. ORNL also participated in almost all of the various technical areas of the U.S. Department of Energy s Robotics Technology Development Program, while leading the Decontamination and Decommissioning and Tank Waste Retrieval categories. Over the course of this involvement, ORNL has developed a substantial base of working knowledge as to what works when and under what circumstances for many types of remote systems tasks as well as operator interface modes, control bandwidth, and sensing requirements to name a few. By using a select list of manipulator systems that is not meant to be exhaustive, this paper will discuss history and outcome of development, field-testing, deployment, and operations from a lessons learned perspective. The final outcome is a summary paper outlining ORNL experiences and guidelines for transition of developmental remote systems to real-world hazardous environments.

  10. Near Field UHF RFID Antenna System Enabling the Tracking of Small Laboratory Animals

    Directory of Open Access Journals (Sweden)

    Luca Catarinucci

    2013-01-01

    Full Text Available Radio frequency identification (RFID technology is more and more adopted in a wide range of applicative scenarios. In many cases, such as the tracking of small-size living animals for behaviour analysis purposes, the straightforward use of commercial solutions does not ensure adequate performance. Consequently, both RFID hardware and the control software should be tailored for the particular application. In this work, a novel RFID-based approach enabling an effective localization and tracking of small-sized laboratory animals is proposed. It is mainly based on a UHF Near Field RFID multiantenna system, to be placed under the animals’ cage, and able to rigorously identify the NF RFID tags implanted in laboratory animals (e.g., mice. Once the requirements of the reader antenna have been individuated, the antenna system has been designed and realized. Moreover, an algorithm based on the measured Received Signal Strength Indication (RSSI aiming at removing potential ambiguities in data captured by the multiantenna system has been developed and integrated. The animal tracking system has been largely tested on phantom mice in order to verify its ability to precisely localize each subject and to reconstruct its path. The achieved and discussed results demonstrate the effectiveness of the proposed tracking system.

  11. Laboratory testing of the in-well vapor-stripping system

    International Nuclear Information System (INIS)

    Gilmore, T.J.; Francois, O.

    1996-03-01

    The Volatile organic Compounds-Arid Integrated Demonstration (VOC-Arid ID) was implemented by the US Department of Energy's (DOE's) Office of Technology Development to develop and test new technologies for the remediation of organic chemicals in the subsurface. One of the technologies being tested under the VOC-Arid ID is the in-well vapor-stripping system. The in-well vapor-stripping concept was initially proposed by researchers at Stanford University and is currently under development through a collaboration between workers at Stanford University and DOE's Pacific Northwest National Laboratory. The project to demonstrate the in-well vapor-stripping technology is divided into three phases: (1) conceptual model and computer simulation, (2) laboratory testing, and (3) field demonstration. This report provides the methods and results of the laboratory testing in which a full-scale replica was constructed and tested above ground in a test facility located at DOE's Hanford Site, Washington. The system is a remediation technology designed to preferentially extract volatile organic compounds (VOCs) from contaminated groundwater by converting them to a vapor phase

  12. Experience of quality management system in a clinical laboratory in Nigeria

    Directory of Open Access Journals (Sweden)

    Rosemary A. Audu

    2012-10-01

    Description: In 2005, two personnel from the HVL spent time studying quality systems in a certified clinical laboratory in Dakar, Senegal. Following this peer-to-peer technical assistance, several training sessions were undertaken by HVL staff, a baseline assessment was conducted, and processes were established. The HVL has monitored its quality indicators and conducted internal and external audits; these analyses (from 2007 to 2009 are presented herein. Lessons learned: Although there was improvement in the pre-analytical and analytical indicators analysed and although data-entry errors decreased in the post-analytical process, the delay in returning laboratory test results increased significantly. There were several factors identified as causes for this delay and all of these have now been addressed except for an identified need for automation of some high-volume assays (currently being negotiated. Internal and external audits showed a trend of increasing non-conformities which could be the result of personnel simply becoming lax over time. Application for laboratory accreditation, however, could provide the renewed vigour needed to correct these non-conformities. Recommendation: This experience shows that sustainability of the QMS at present is a cause for concern. However, the tiered system of accreditation being developed by WHO–Afro may act as a driving force to preserve the spirit of continual improvement.

  13. Development of Rhizo-Columns for Nondestructive Root System Architecture Laboratory Measurements

    Science.gov (United States)

    Oostrom, M.; Johnson, T. J.; Varga, T.; Hess, N. J.; Wietsma, T. W.

    2016-12-01

    Numerical models for root water uptake in plant-soil systems have been developing rapidly, increasing the demand for laboratory experimental data to test and verify these models. Most of the increasingly detailed models are either compared to long-term field crop data or do not involve comparisons at all. Ideally, experiments would provide information on dynamic root system architecture (RSA) in combination with soil-pant hydraulics such as water pressures and volumetric water contents. Data obtained from emerging methods such as Spectral Induced Polarization (SIP) and x-ray computed tomography (x-ray CT) may be used to provide laboratory RSA data needed for model comparisons. Point measurements such as polymer tensiometers (PT) may provide soil moisture information over a large range of water pressures, from field capacity to the wilting point under drought conditions. In the presentation, we demonstrate a novel laboratory capability allowing for detailed RSA studies in large columns under controlled conditions using automated SIP, X-ray CT, and PT methods. Examples are shown for pea and corn root development under various moisture regimes.

  14. Interactive system for quick modeling of aircraft surfaces

    Science.gov (United States)

    Mudur, S. P.; Khandekar, Dilip R.

    1990-08-01

    The precise specification of surface geometry of an aircraft is one of the most important and major activities inits design. An initial design, defined by the fundamental requirements, is iteratively analysed and modified till a satisfactory configuration is obtained. Very often in the early stages the need to rapidly make modifications to the geometry for immediate analysis overrides the stringency of smoothness and correctness ofthe surfaces. This paper describes the design of an interactive system which enables the designer to quickly specify the surface geometry and to modify it easily and rapidly. In particular, the software engineering aspects are emphasized. The system uses B-splines for the representation of complex geometry. Surfaces of revolution, required to model certain parts ofthe aircraft, and other simple geometric primitives are also supported. Apart from the usual modeller facilities, features such as camber, twist and form constraints such as tangent or curvature control at a point, etc., are also provided. The system enables easy input and rapid editing of geomeiry through the use of a number of innovative concepts which aim at simplifying and speeding up the man-machine interaction. Multiple window display of entities, augmented by plots of curvature, cross sections etc. provide the visualization tool necessary to assist the designer in decision making.

  15. Data Analysis Techniques for a Lunar Surface Navigation System Testbed

    Science.gov (United States)

    Chelmins, David; Sands, O. Scott; Swank, Aaron

    2011-01-01

    NASA is interested in finding new methods of surface navigation to allow astronauts to navigate on the lunar surface. In support of the Vision for Space Exploration, the NASA Glenn Research Center developed the Lunar Extra-Vehicular Activity Crewmember Location Determination System and performed testing at the Desert Research and Technology Studies event in 2009. A significant amount of sensor data was recorded during nine tests performed with six test subjects. This paper provides the procedure, formulas, and techniques for data analysis, as well as commentary on applications.

  16. Virtual Earth System Laboratory (VESL): A Virtual Research Environment for The Visualization of Earth System Data and Process Simulations

    Science.gov (United States)

    Cheng, D. L. C.; Quinn, J. D.; Larour, E. Y.; Halkides, D. J.

    2017-12-01

    The Virtual Earth System Laboratory (VESL) is a Web application, under continued development at the Jet Propulsion Laboratory and UC Irvine, for the visualization of Earth System data and process simulations. As with any project of its size, we have encountered both successes and challenges during the course of development. Our principal point of success is the fact that VESL users can interact seamlessly with our earth science simulations within their own Web browser. Some of the challenges we have faced include retrofitting the VESL Web application to respond to touch gestures, reducing page load time (especially as the application has grown), and accounting for the differences between the various Web browsers and computing platforms.

  17. Surface moisture measurement system hardware acceptance test procedure

    International Nuclear Information System (INIS)

    Ritter, G.A.

    1996-01-01

    The purpose of this acceptance test procedure is to verify that the mechanical and electrical features of the Surface Moisture Measurement System are operating as designed and that the unit is ready for field service. This procedure will be used in conjunction with a software acceptance test procedure, which addresses testing of software and electrical features not addressed in this document. Hardware testing will be performed at the 306E Facility in the 300 Area and the Fuels and Materials Examination Facility in the 400 Area. These systems were developed primarily in support of Tank Waste Remediation System (TWRS) Safety Programs for moisture measurement in organic and ferrocyanide watch list tanks

  18. Stepwise approach to establishing multiple outreach laboratory information system-electronic medical record interfaces

    Directory of Open Access Journals (Sweden)

    Liron Pantanowitz

    2010-01-01

    Full Text Available Clinical laboratory outreach business is changing as more physician practices adopt an electronic medical record (EMR. Physician connectivity with the laboratory information system (LIS is consequently becoming more important. However, there are no reports available to assist the informatician with establishing and maintaining outreach LIS-EMR connectivity. A four-stage scheme is presented that was successfully employed to establish unidirectional and bidirectional interfaces with multiple physician EMRs. This approach involves planning (step 1, followed by interface building (step 2 with subsequent testing (step 3, and finally ongoing maintenance (step 4. The role of organized project management, software as a service (SAAS, and alternate solutions for outreach connectivity are discussed.

  19. Pacific Northwest National Laboratory Facility Radionuclide Emission Points and Sampling Systems

    Energy Technology Data Exchange (ETDEWEB)

    Barfuss, Brad C.; Barnett, J. Matthew; Ballinger, Marcel Y.

    2009-04-08

    Battelle—Pacific Northwest Division operates numerous research and development laboratories in Richland, Washington, including those associated with the Pacific Northwest National Laboratory (PNNL) on the Department of Energy’s Hanford Site that have the potential for radionuclide air emissions. The National Emission Standard for Hazardous Air Pollutants (NESHAP 40 CFR 61, Subparts H and I) requires an assessment of all effluent release points that have the potential for radionuclide emissions. Potential emissions are assessed annually. Sampling, monitoring, and other regulatory compliance requirements are designated based upon the potential-to-emit dose criteria found in the regulations. The purpose of this document is to describe the facility radionuclide air emission sampling program and provide current and historical facility emission point system performance, operation, and design information. A description of the buildings, exhaust points, control technologies, and sample extraction details is provided for each registered or deregistered facility emission point. Additionally, applicable stack sampler configuration drawings, figures, and photographs are provided.

  20. Real-time dosimetry system in catheterisation laboratory: utility as a learning tool in radiation protection

    International Nuclear Information System (INIS)

    Pinto Monedero, M.; Rodriguez Cobo, C.; Pifarre Martinez, X.; Ruiz Martin, J.; Barros Candelero, J.M.; Goicolea Ruigomez, J.; Diaz Blaires, G.; Garcia Lunar, I.

    2015-01-01

    Document available in abstract form only. Full text of publication follows: Workers at the catheter laboratory are among the most exposed to ionising radiation in hospitals. However, it is difficult to be certain of the radiation doses received by the staff, as personal dosemeters are often misused, and thus, the dose history is not reliable. Moreover, the information provided by personal dosemeters corresponds to the monthly accumulated dose, so corrective actions tends to be delayed. The purpose of this work is, on the one hand, to use a real-time dosimetry system to establish the occupational doses per procedure of workers at the catheter laboratories and, on the other hand, to evaluate its utility as a learning tool for radiation protection purposes with the simultaneous video recording of the interventions. (authors)