WorldWideScience

Sample records for surface dose large

  1. Surface dose in intracavitary orthovoltage radiotherapy

    International Nuclear Information System (INIS)

    Podgorsak, M.B.; Schreiner, L.J.; Podgorsak, E.B.

    1990-01-01

    Radiotherapy with orthovoltage techniques is often the prime treatment for localized superficial malignancies. Surface doses and depth doses measured with cylindrical and end-window Farmer chambers are presented for various orthovoltage x-ray beams in the range from 80 to 300 kVp, both for open beams and beams collimated with commercial intracavitary leaded-glass cones. For radiation fields collimated by a diaphragm positioned at a distance from the patient surface (open beams) there is a small skin-sparing effect. On the other hand, the surface doses with commercial leaded-glass intracavitary cones can exhibit a fivefold increase compared to the open-beam dose maxima. Beyond a depth of ∼0.2 mm in a tissue-equivalent phantom, the doses measured for open beams and beams collimated with intracavitary cones are essentially identical. The increase in the surface dose observed with intracavitary cones is attributed to photoelectrons and recoil electrons produced in the cones. The high surface doses are measured by thin-wall parallel-plate ionization chambers but cannot be measured with cylindrical Farmer chambers since these chambers have wall thicknesses too large for the transmission of electrons produced in the cone. Since cylindrical Farmer chambers are typically used for calibration of radiation output, the high surface doses produced by the intracavitary cones may be overlooked; they can, however, be reduced to open-beam values by simple modifications to the cones

  2. Dose reduction factors from a radioactive cloud for large buildings

    International Nuclear Information System (INIS)

    Grand, J. le; Roux, Y.

    1986-01-01

    A set of complex and accurate computer codes has been established to determine the transport of photons emitted from a radioactive cloud through various media. The geometrical and physical description of large buildings with various numbers of floors and rooms can be done by the user. The codes can calculate, in any room or apartment, the characteristics of the photon fields (photon flux, energy flux and distribution, direction distribution) and whole-body absorbed dose rates in a phantom standing or lying on the floor. The dose reduction factor is then the quotient of the mean absorbed dose rate in the apartment to the absorbed dose rate in the phantom standing on the ground outdoors. Applications to several modern multistorey buildings are presented. The results show the influence of various parameters such as density and composition of building materials, the fraction of the external building surface containing apertures and initial photon energy. (author)

  3. Dose reduction factors from a radioactive cloud for large buildings

    Energy Technology Data Exchange (ETDEWEB)

    Grand, J. le; Roux, Y.; Patau, J.P.

    1986-01-01

    A set of complex and accurate computer codes has been established to determine the transport of photons emitted from a radioactive cloud through various media. The geometrical and physical description of large buildings with various numbers of floors and rooms can be done by the user. The codes can calculate, in any room or apartment, the characteristics of the photon fields (photon flux, energy flux and distribution, direction distribution) and whole-body absorbed dose rates in a phantom standing or lying on the floor. The dose reduction factor is then the quotient of the mean absorbed dose rate in the apartment to the absorbed dose rate in the phantom standing on the ground outdoors. Applications to several modern multistorey buildings are presented. The results show the influence of various parameters such as density and composition of building materials, the fraction of the external building surface containing apertures and initial photon energy.

  4. Surface dose extrapolation measurements with radiographic film

    International Nuclear Information System (INIS)

    Butson, Martin J; Cheung Tsang; Yu, Peter K N; Currie, Michael

    2004-01-01

    Assessment of surface dose delivered from radiotherapy x-ray beams for optimal results should be performed both inside and outside the prescribed treatment fields. An extrapolation technique can be used with radiographic film to perform surface dose assessment for open field high energy x-ray beams. This can produce an accurate two-dimensional map of surface dose if required. Results have shown that the surface percentage dose can be estimated within ±3% of parallel plate ionization chamber results with radiographic film using a series of film layers to produce an extrapolated result. Extrapolated percentage dose assessment for 10 cm, 20 cm and 30 cm square fields was estimated to be 15% ± 2%, 29% ± 3% and 38% ± 3% at the central axis and relatively uniform across the treatment field. The corresponding parallel plate ionization chamber measurements are 16%, 27% and 37%, respectively. Surface doses are also measured outside the treatment field which are mainly due to scattered electron contamination. To achieve this result, film calibration curves must be irradiated to similar x-ray field sizes as the experimental film to minimize quantitative variations in film optical density caused by varying x-ray spectrum with field size. (note)

  5. Review of surface dose detectors in radiotherapy

    LENUS (Irish Health Repository)

    O'Shea, E.

    2006-11-20

    Several instruments have been used to measure absorbed radiation dose under non-electronic equilibrium conditions, such as in the build-up region or near the interface between two different media, including the surface. Many of these detectors are discussed in this paper. A common method of measuring the absorbed dose distribution and electron contamination in the build-up region of high-energy beams for radiation therapy is by means of parallel-plate ionisation chambers. Thermoluminescent dosimeters (TLDs), diodes and radiographic film have also been used to obtain surface dose measurements. The diamond detector was used recently by the author in an investigation on the effects of beam-modifying devices on skin dose and it is also described in this report

  6. Variation of surface dose in CT

    International Nuclear Information System (INIS)

    Aviles Lucas, P.; Castellano, I. A.; Dance, D. R.; Vano Carruana, E.; Prieto Martin, C.

    2003-01-01

    An experimental study has been made of the variations of the air kerma-length product at the surface of a phantom exposed in a CT scanner using clinical parameters. the effect of patient size, position within the gantry plane and beam-shaping filter type was studied using three different elliptical phantoms. A dose reduction technique based on a sinusoidal tube current modulation system was also investigated. the result of the variation of the surface dose was analysed for the case of CT fluoroscopy procedures. The surface air kerma-length product was shown to be independent of phantom size (within experimental error) but decreases as the surface moves vertically away from the iso centre. The major contributor to this variation the beam-shaping filter. The possibility of underestimating the surface dose if an AAPM body phantom is used (a 36% increase for the head phantom) is an indirect result of the previous conclusion when applied to CT fluoroscopy. This highlights the importance of considering the size and position of the patient when measuring the does. Finally, when the tube current modulation system was used, the maximum surface dose reduction was 18%. (Author) 23 refs

  7. The characteristics on dose distribution of a large field

    International Nuclear Information System (INIS)

    Lee, Sang Rok; Jeong, Deok Yang; Lee, Btiung Koo; Kwon, Young Ho

    2003-01-01

    In special cases of Total Body Irradiation(TBI), Half Body Irradiation(HBI), Non-Hodgkin's lymphoma, E-Wing's sarcoma, lymphosarcoma and neuroblastoma a large field can be used clinically. The dose distribution of a large field can use the measurement result which gets from dose distribution of a small field (standard SSD 100 cm, size of field under 40 x 40 cm 2 ) in the substitution which always measures in practice and it will be able to calibrate. With only the method of simple calculation, it is difficult to know the dose and its uniformity of actual body region by various factor of scatter radiation. In this study, using Multidata Water Phantom from standard SSD 100 cm according to the size change of field, it measures the basic parameter (PDD,TMR,Output,Sc,Sp) From SSD 180 cm (phantom is to the bottom vertically) according to increasing of a field, it measures a basic parameter. From SSD 350 cm (phantom is to the surface of a wall, using small water phantom. which includes mylar capable of horizontal beam's measurement) it measured with the same method and compared with each other. In comparison with the standard dose data, parameter which measures between SSD 180 cm and 350 cm, it turned out there was little difference. The error range is not up to extent of the experimental error. In order to get the accurate data, it dose measures from anthropomorphous phantom or for this objective the dose measurement which is the possibility of getting the absolute value which uses the unlimited phantom that is devised especially is demanded. Additionally, it needs to consider ionization chamber use of small volume and stem effect of cable by a large field.

  8. Patient surface doses in computerized tomography examinations

    International Nuclear Information System (INIS)

    Vekic, B; Kovacevic, S.; Ranogajec-Komor, M.; Duvnjak, N.; Marusic, P.; Anic, P.; Dolencic, P.

    1996-01-01

    The diagnostic value of computerized tomography has increased due to very rapid technical advances in both equipment and techniques. When the CT scanners were introduced, a significant problem for the specification of the radiation dose imparted to the patient undergoing CT examination has been created. In CT, the conditions of exposure are quite different from those in conventional X-ray imaging. CT procedure involves the continuous tomography of thin layers. Some of these layers touch each other while others overlap. The radiation doses received by patients can vary considerably. In addition to the radiation from the collimated primary beam, patients are exposed to significant scattered doses in unpredictable amounts. Every effort should be made to keep these doses to a reasonable minimum, without sacrificing the image quality. The aims of this work were to determine the surface doses delivered to various organs of patients during various computerized tomography examinations (head, thorax, kidney, abdomen and pelvis). Particular attention was directed to the precise determination of doses received by the eyes (during CT of head) and gonads (during CT of pelvis and lower abdomen) since these organs can be near or even in the primary X-ray beam

  9. Determination of Absorbed Dose in Large 60-Co Fields Radiotherapy

    International Nuclear Information System (INIS)

    Hrsak, H.

    2003-01-01

    Radiation in radiotherapy has selective impact on ill and healthy tissue. During the therapy the healthy tissue receives certain amount of dose. Therefore dose calculations in outer radiotherapy must be accurate because too high doses produce damage in healthy tissue and too low doses cannot ensure efficient treatment of cancer cells. A requirement on accuracy in the dose calculations has lead to improvement of detectors, and development of absolute and relative dosimetry. Determination of the dose distribution with use of computer is based on data provided by the relative dosimetry. This paper compares the percentage depth doses in cubic water phantoms of various dimensions with percentage depth doses calculated with use of Mayneord factor from the experimental depth doses measured in water phantom of large dimension. Depth doses in water phantoms were calculated by the model of empirical dosimetrical functions. The calculations were based on the assumption that large 6 0C o photon field exceeds the phantom's limits. The experimental basis for dose calculations by the model of empirical dosimetrical functions were exposure doses measured in air and dose reduction factors because of finite phantom dimensions. Calculations were performed by fortran 90 software. It was found that the deviation of dosimetric model was small in comparison to the experimental data. (author)

  10. Entrance surface dose according to dose calculation: Head and wrist

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Ho Jin [Dept. Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of); Han, Jae Bok; Song, Jong Nam; Choi, Nam Gil [Dept. of Radiological Science, Dongshin University, Naju (Korea, Republic of)

    2016-09-15

    This study were compared with the direct measurement and indirect dose methods through various dose calculation in head and wrist. And, the modified equation was proposed considering equipment type, setting conditions, tube voltage, inherent filter, added filter and its accompanied back scatter factor. As a result, it decreased the error of the direct measurement than the existing dose calculation. Accordingly, diagnostic radiography patient dose comparison would become easier and radiographic exposure control and evaluation will become more efficient. The study findings are expected to be useful in patients' effective dose rate evaluation and dose reduction.

  11. Assessment of large aperture scintillometry for large-area surface ...

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Earth System Science; Volume 126; Issue 5. Assessment of large aperture scintillometry for large-area surface energy fluxes over an irrigated cropland in north India. Abhishek Danodia V K Sehgal N R Patel R Dhakar J Mukherjee S K Saha A Senthil Kumar. Volume 126 Issue 5 July 2017 Article ...

  12. Entrance surface dose of the common radiological investigations in ...

    African Journals Online (AJOL)

    The entrance surface Dose (ESD) was determined among patients who presented for routine radiological examinations using thermoluminescent dosimeter (TLD) chips placed on averagely built adult [ (30cm) chest width, 60 - 90kg weight and 20-40years)] by multiplying the incident dose/entrances dose by the back ...

  13. SU-E-T-577: Obliquity Factor and Surface Dose in Proton Beam Therapy

    International Nuclear Information System (INIS)

    Das, I; Andersen, A; Coutinho, L

    2015-01-01

    Purpose: The advantage of lower skin dose in proton beam may be diminished creating radiation related sequalae usually seen with photon and electron beams. This study evaluates the surface dose as a complex function of beam parameters but more importantly the effect of beam angle. Methods: Surface dose in proton beam depends on the beam energy, source to surface distance, the air gap between snout and surface, field size, material thickness in front of surface, atomic number of the medium, beam angle and type of nozzle (ie double scattering, (DS), uniform scanning (US) or pencil beam scanning (PBS). Obliquity factor (OF) is defined as ratio of surface dose in 0° to beam angle Θ. Measurements were made in water phantom at various beam angles using very small microdiamond that has shown favorable beam characteristics for high, medium and low proton energy. Depth dose measurements were performed in the central axis of the beam in each respective gantry angle. Results: It is observed that surface dose is energy dependent but more predominantly on the SOBP. It is found that as SSD increases, surface dose decreases. In general, SSD, and air gap has limited impact in clinical proton range. High energy has higher surface dose and so the beam angle. The OF rises with beam angle. Compared to OF of 1.0 at 0° beam angle, the value is 1.5, 1.6, 1,7 for small, medium and large range respectively for 60 degree angle. Conclusion: It is advised that just like range and SOBP, surface dose should be clearly understood and a method to reduce the surface dose should be employed. Obliquity factor is a critical parameter that should be accounted in proton beam therapy and a perpendicular beam should be used to reduce surface dose

  14. Dose banding as an alternative to body surface area-based dosing of chemotherapeutic agents

    NARCIS (Netherlands)

    E. Chatelut (Etienne); M.L. White-Koning (M.); A.H.J. Mathijssen (Ron); F. Puisset (F.); S.D. Baker (Sharyn); A. Sparreboom (Alex)

    2012-01-01

    textabstractBackground: Dose banding is a recently suggested dosing method that uses predefined ranges (bands) of body surface area (BSA) to calculate each patients dose by using a single BSA-value per band. Thus, drugs with sufficient long-term stability can be prepared in advance. The main

  15. Results of large scale thyroid dose reconstruction in Ukraine

    International Nuclear Information System (INIS)

    Likhtarev, I.; Sobolev, B.; Kairo, I.; Tabachny, L.; Jacob, P.; Proehl, G.; Goulko, G.

    1996-01-01

    In 1993, the Ukrainian Ministry on Chernobyl Affairs initiated a large scale reconstruction of thyroid exposures to radioiodine after the Chernobyl accident. The objective was to provide the state policy on social compensations with a scientific background. About 7000 settlements from five contaminated regions have gotten certificates of thyroid exposure since then. Certificates contain estimates of the average thyroid dose from 131 I for seven age groups. The primary dose estimates used about 150000 direct measurements of the 131 I activity in the thyroid glands of inhabitants from Chernigiv, Kiev, Zhytomyr, and also Vinnytsa regions. Parameters of the assumed intake function were related to environmental and questionnaire data. The dose reconstruction for the remaining territory was based on empirical relations between intake function parameters and the 137 Cs deposition. The relationship was specified by the distance and the direction to the Chernobyl Nuclear Power Plant. The relations were first derived for territories with direct measurements and then they were spread on other areas using daily iodine releases and atmospheric transportation routes. The results of the dose reconstruction allowed to mark zones on the territory of Ukraine according to the average levels of thyroid exposures. These zones underlay a policy of post-accidental health care and social compensations. Another important application of the thyroid dose reconstruction is the radiation risk assessment of thyroid cancer among people exposed during childhood due to the Chernobyl accident

  16. Plastic film materials for dosimetry of very large absorbed doses

    DEFF Research Database (Denmark)

    McLaughlin, W.L.; Miller, Arne; Abdel-Rahim, F.

    1985-01-01

    , polystyrene, dyed and undyed polyhalostyrenes, dyed aromatic polyamides, and polyvinylidene fluoride. Although most of these systems have fairly stable absorption spectra after irradiation, tests of dependence on dose rate and on temperature during irradiation show that only polystyrene and some...... of the polyhalostyrenes have essentially rate-independent and moderately temperature-dependent responses to such large doses of ionizing radiation. While radiation-induced optical absorption in the ultraviolet for polystyrene is unstable following irradiation, thus leading to an intrinsic low-intensity rate dependence......, the dyed polychlorostyrenes show essentially the same response to radiation-processing gamma-ray fields and to very high-intensity electron beams, and a relatively stable absorption spectrum at wavelengths for dosimetry analysis in the visible spectral region of ≈430 nm....

  17. Decontamination of large horizontal concrete surfaces outdoors

    International Nuclear Information System (INIS)

    Barbier, M.M.; Chester, C.V.

    1980-01-01

    A study is being conducted of the resources and planning that would be required to clean up an extensive contamination of the outdoor environment. As part of this study, an assessment of the fleet of machines needed for decontaminating large outdoor surfaces of horizontal concrete will be attempted. The operations required are described. The performance of applicable existing equipment is analyzed in terms of area cleaned per unit time, and the comprehensive cost of decontamination per unit area is derived. Shielded equipment for measuring directional radiation and continuously monitoring decontamination work are described. Shielding of drivers' cabs and remote control vehicles is addressed

  18. NOTE: Surface dose extrapolation measurements with radiographic film

    Science.gov (United States)

    Butson, Martin J.; Cheung, Tsang; Yu, Peter K. N.; Currie, Michael

    2004-07-01

    Assessment of surface dose delivered from radiotherapy x-ray beams for optimal results should be performed both inside and outside the prescribed treatment fields. An extrapolation technique can be used with radiographic film to perform surface dose assessment for open field high energy x-ray beams. This can produce an accurate two-dimensional map of surface dose if required. Results have shown that the surface percentage dose can be estimated within ±3% of parallel plate ionization chamber results with radiographic film using a series of film layers to produce an extrapolated result. Extrapolated percentage dose assessment for 10 cm, 20 cm and 30 cm square fields was estimated to be 15% ± 2%, 29% ± 3% and 38% ± 3% at the central axis and relatively uniform across the treatment field. The corresponding parallel plate ionization chamber measurements are 16%, 27% and 37%, respectively. Surface doses are also measured outside the treatment field which are mainly due to scattered electron contamination. To achieve this result, film calibration curves must be irradiated to similar x-ray field sizes as the experimental film to minimize quantitative variations in film optical density caused by varying x-ray spectrum with field size.

  19. Hematological changes after single large dose half-body irradiation

    International Nuclear Information System (INIS)

    Herrmann, T.; Friedrich, S.; Jochem, I.; Eberhardt, H.J.; Koch, R.; Knorr, A.

    1981-01-01

    The determination of different peripheral blood parameters aimed at the study of side effects on the hematological cellular system following a 5 - 8 Gy single large dose half-body irradiation in 20 patients. Compared to the initial values the leukocytes between the 6. and 14., the thrombocytes between the 14. and 21. postirradiation day as well as the lymphocytes between 3 hours and 4 weeks postirradiation were significantly decreased without exhibiting complications such as hemorrhages or infections. The hemoglobin, hematocrit and reticulocyte values revealed but a slight decrease normalized within a 28 days postirradiation period. Transfusions were necessary when a tumor-caused anemia was present prior to irradiation. Changes in serum activity of aminotransferases and lactate dehydrogenase occured during the first hours after irradiation and were due to enzyme release from destroyed tumor cells

  20. Surface slip during large Owens Valley earthquakes

    KAUST Repository

    Haddon, E. K.

    2016-01-10

    The 1872 Owens Valley earthquake is the third largest known historical earthquake in California. Relatively sparse field data and a complex rupture trace, however, inhibited attempts to fully resolve the slip distribution and reconcile the total moment release. We present a new, comprehensive record of surface slip based on lidar and field investigation, documenting 162 new measurements of laterally and vertically displaced landforms for 1872 and prehistoric Owens Valley earthquakes. Our lidar analysis uses a newly developed analytical tool to measure fault slip based on cross-correlation of sublinear topographic features and to produce a uniquely shaped probability density function (PDF) for each measurement. Stacking PDFs along strike to form cumulative offset probability distribution plots (COPDs) highlights common values corresponding to single and multiple-event displacements. Lateral offsets for 1872 vary systematically from approximate to 1.0 to 6.0 m and average 3.31.1 m (2 sigma). Vertical offsets are predominantly east-down between approximate to 0.1 and 2.4 m, with a mean of 0.80.5 m. The average lateral-to-vertical ratio compiled at specific sites is approximate to 6:1. Summing displacements across subparallel, overlapping rupture traces implies a maximum of 7-11 m and net average of 4.41.5 m, corresponding to a geologic M-w approximate to 7.5 for the 1872 event. We attribute progressively higher-offset lateral COPD peaks at 7.12.0 m, 12.8 +/- 1.5 m, and 16.6 +/- 1.4 m to three earlier large surface ruptures. Evaluating cumulative displacements in context with previously dated landforms in Owens Valley suggests relatively modest rates of fault slip, averaging between approximate to 0.6 and 1.6 mm/yr (1 sigma) over the late Quaternary.

  1. Dose distribution considerations of medium energy electron beams at extended source-to-surface distance

    International Nuclear Information System (INIS)

    Saw, Cheng B.; Ayyangar, Komanduri M.; Pawlicki, Todd; Korb, Leroy J.

    1995-01-01

    Purpose: To determine the effects of extended source-to-surface distance (SSD) on dose distributions for a range of medium energy electron beams and cone sizes. Methods and Materials: The depth-dose curves and isodose distributions of 6 MeV, 10 MeV, and 14 MeV electron beams from a dual photon and multielectron energies linear accelerator were studied. To examine the influence of cone size, the smallest and the largest cone sizes available were used. Measurements were carried out in a water phantom with the water surface set at three different SSDs from 101 to 116 cm. Results: In the region between the phantom surface and the depth of maximum dose, the depth-dose decreases as the SSD increases for all electron beam energies. The effects of extended SSD in the region beyond the depth of maximum dose are unobservable and, hence, considered minimal. Extended SSD effects are apparent for higher electron beam energy with small cone size causing the depth of maximum dose and the rapid dose fall-off region to shift deeper into the phantom. However, the change in the depth-dose curve is small. On the other hand, the rapid dose fall-off region is essentially unaltered when the large cone is used. The penumbra enlarges and electron beam flatness deteriorates with increasing SSD

  2. Assessment of large aperture scintillometry for large-area surface ...

    Indian Academy of Sciences (India)

    29

    This study defines that large aperture scintillometer is robust instrument which can evaluate energy flux over a large area with a long term series time domain. Moreover, further studied should be conducted to use in crop simulation modelling, developing of new model with calibration and validation of remote sensing energy ...

  3. Entrance surface dose in cerebral interventional radiology procedures

    International Nuclear Information System (INIS)

    Barrera-Rico, M.; López-Rendón, X.; Vega-Montesino, S.; Gamboa-deBuen, I.

    2014-01-01

    During interventional radiology procedures patients receive doses which exceed thresholds for non-stochastic effects on the skin, such as erythema (2 Gy) and epilation (3 Gy), so the entrance surface dose imparted during these proceedings should be monitored. The aim of this work was to determine the entrance surface dose (ESD) in patients who undergo diagnostic or therapeutic procedures at the Instituto Nacional de Neurología y Neurocirugía (INNN). The procedures were performed using two systems for neuroradiology, an Axiom Artis and an Artis Zeego from Siemens. The ESD was measured, for diagnostic and therapeutic procedures, using 15 × 15 cm 2 of Gafchromic XR-RV3 film and/or 25 TLD-100 chips that were attached in a holder of 15 × 15 cm 2 in the posteroanterior and left and right lateral positions during all the procedures. The results show that the maximum ESD measured was lower than 1 Gy for the nine diagnostic procedures evaluated whereas four of the ten therapeutic procedures were greater than 2 Gy in at least one position. Seven patients were monitored, three of which have presented epilation and one erythema. - Highlights: • We measured the entrance surface dose in cerebral interventional radiology. • Entrance surface doses were lower than 1 Gy for diagnostic procedures. • In four therapeutic procedures entrance surface doses were greater than 2 Gy. • Three patients presented epilation and one erythema

  4. Surface slip during large Owens Valley earthquakes

    Science.gov (United States)

    Haddon, E.K.; Amos, C.B.; Zielke, O.; Jayko, Angela S.; Burgmann, R.

    2016-01-01

    The 1872 Owens Valley earthquake is the third largest known historical earthquake in California. Relatively sparse field data and a complex rupture trace, however, inhibited attempts to fully resolve the slip distribution and reconcile the total moment release. We present a new, comprehensive record of surface slip based on lidar and field investigation, documenting 162 new measurements of laterally and vertically displaced landforms for 1872 and prehistoric Owens Valley earthquakes. Our lidar analysis uses a newly developed analytical tool to measure fault slip based on cross-correlation of sublinear topographic features and to produce a uniquely shaped probability density function (PDF) for each measurement. Stacking PDFs along strike to form cumulative offset probability distribution plots (COPDs) highlights common values corresponding to single and multiple-event displacements. Lateral offsets for 1872 vary systematically from ∼1.0 to 6.0 m and average 3.3 ± 1.1 m (2σ). Vertical offsets are predominantly east-down between ∼0.1 and 2.4 m, with a mean of 0.8 ± 0.5 m. The average lateral-to-vertical ratio compiled at specific sites is ∼6:1. Summing displacements across subparallel, overlapping rupture traces implies a maximum of 7–11 m and net average of 4.4 ± 1.5 m, corresponding to a geologic Mw ∼7.5 for the 1872 event. We attribute progressively higher-offset lateral COPD peaks at 7.1 ± 2.0 m, 12.8 ± 1.5 m, and 16.6 ± 1.4 m to three earlier large surface ruptures. Evaluating cumulative displacements in context with previously dated landforms in Owens Valley suggests relatively modest rates of fault slip, averaging between ∼0.6 and 1.6 mm/yr (1σ) over the late Quaternary.

  5. SU-F-18C-12: On the Relationship of the Weighted Dose to the Surface Dose In Abdominal CT - Patient Size Dependency

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Y; Scott, A; Allahverdian, J [Cedars-Sinai Medical Center, Los Angeles, CA (United States)

    2014-06-15

    Purpose: It is possible to measure the patient surface dose non-invasively using radiolucent dosimeters. However, the patient size specific weighted dose remains unknown. We attempted to study the weighted dose to surface dose relationship as the patient size varies in abdominal CT. Methods: Seven abdomen phantoms (CIRS TE series) simulating patients from an infant to a large adult were used. Size specific doses were measured with a 100 mm CT chamber under axial scans using a Siemens Sensation 64 (mCT) and a GE 750 HD. The scanner settings were 120 kVp, 200 mAs with fully opened collimations. Additional kVps (80, 100, 140) were added depending on the phantom sizes. The ratios (r) of the weighted CT dose (Dw) to the surface dose (Ds) were related to the phantom size (L) defined as the diameter resulting the equivalent cross-sectional area. Results: The Dw versus Ds ratio (r) was fitted to a linear relationship: r = 1.083 − 0.007L (R square = 0.995), and r = 1.064 − 0.007L (R square = 0.953), for Siemens Sensation 64 and GE 750 HD, respectively. The relationship appears to be independent of the scanner specifics. Conclusion: The surface dose to the weighted dose ratio decreases linearly as the patient size increases. The result is independent of the scanner specifics. The result can be used to obtain in vivo CT dosimetry in abdominal CT.

  6. Dose-area product and entrance surface dose in paediatric radiography

    Energy Technology Data Exchange (ETDEWEB)

    Servomaa, A.; Komppa, T.; Parviainen, T.; Heikkilae, M. [STUK - Radiation and Nuclear Safety Authority, Helsinki (Finland)

    2003-06-01

    Dose-area products (DAP) in paediatric radiography were measured in four university hospitals in Finland. The entrance surface dose (ESD) was calculated from the measured DAP value for each radiographic projection. The purpose was to combine the results with other European studies for development of diagnostic reference levels for paediatric X-ray examinations. The study included 740 paediatric patients, and a total of 1500 single projections were recorded, including 660 projections from extremities. Results were compared with recommended best practices and diagnostic reference levels for ESD. Ratios of DAP to ESD were studied to estimate the levels of DAP corresponding to recommended ESD reference levels. It is desirable for practical purposes that diagnostic reference levels for radiographic projections are also expressed in terms of dose-area product. (orig.)

  7. Surface doses under head and neck immobilisation devices

    International Nuclear Information System (INIS)

    Baveas, E.

    2004-01-01

    Full text: Methods using ion chambers, TLDs and film were developed to measure the skin-sparing properties of three head and neck immobilisation devices used in radiation therapy, viz. Sinmed multi-perforated and micro-perforated posicast thermoplastic masks (used with a supporting carbon fibre back support), and a Kablite vacuum-formed shell plastic mask (used with a Perspex back support). All measurements were performed with 6 MV beams from Elekta Precise linear accelerators. Two situations have been considered in this study. In the first situation, phantom surface doses under the flat unmoulded mask and back-support materials lying on the surface of a 'solid water' phantom were measured with parallel plate ion chambers and correlated with the physical properties of the materials. In the second situation a particular head and neck treatment technique was adopted and the treatment planned on an anthropomorphic tissue-equivalent phantom. The clinical setup consisted of a wedged pair to the right parotid, planned to deliver a reference dose of 63 Gy to the isocentre, plus an anterior supraclavicular field planned to deliver a reference dose of 50 Gy at a depth of 2 cm. The 3 immobilisation masks were each moulded to the anthropomorphic tissue-equivalent phantom. TLD chips were used to measure the phantom skin dose at a set of 18 locations under each of the 3 immobilisation masks and also without an immobilisation device. The results clearly demonstrate the extent to which the various immobilisation devices increase the surface dose. Results for the first situation are summarised. The averages of the doses recorded by the TLDs in three separate regions for the second situation are shown in Table 2. The combined results show that the areal density of the unmoulded mask materials correlates with the surface dose these materials produce before moulding, but this correlation is lost after moulding for the clinical situation considered. This change upon moulding is

  8. Plastic film materials for dosimetry of very large absorbed doses

    DEFF Research Database (Denmark)

    McLaughlin, W.L.; Miller, Arne; Abdel-Rahim, F.

    1985-01-01

    Most plastic films have limited response ranges for dosimetry because of radiation-induced brittleness, degradation, or saturation of the signal used for analysis (e.g. spectrophotometry) at high doses. There are, however, a few types of thin plastic films showing linearity of response even up...

  9. NANOMETER PRECISION IN LARGE SURFACE PROFILOMETRY

    International Nuclear Information System (INIS)

    TAKACS, P.Z.

    1999-01-01

    The Long Trace Profiler (LTP) is in use at many synchrotron radiation (SR) laboratories throughout the world and by a number of manufacturers who specialize in fabricating grazing incidence mirrors for SR and x-ray telescope applications. Recent improvements in the design and operation of the LTP system have reduced the statistical error in slope profile measurement to the 1 standard deviation level of 0.3 microradian for 0.5 meter long mirrors. This corresponds to a height error on the order of 10-20 nanometers. This level of performance allows one to measure with confidence the absolute shape of large cylindrical aspheres and spheres that have kilometer radii of curvature in the axial direction. The LTP is versatile enough to make measurements of a mirror in the face up, sideways, and face down configurations. We will illustrate the versatility of the current version of the instrument, the LTP II, and present results from two new versions of the instrument: the in situ LTP (ISLTP) and the Vertical Scan LTP (VSLTP). Both of them are based on the penta prism LTP (ppLTP) principle that utilizes a stationary optical head and moving penta prism. The ISLTP is designed to measure the distortion of high heat load mirrors during actual operation in SR beam lines. The VSLTP is designed to measure the complete 3-dimensional shape of x-ray telescope cylinder mirrors and mandrels in a vertical configuration. Scans are done both in the axial direction and in the azimuthal direction

  10. Influence of phantom size on output, peak scatter factor, and percentage depth dose in large-field photon irradiation

    International Nuclear Information System (INIS)

    Podgorsak, E.B.; Pla, C.; Evans, M.D.C.; Pla, M.

    1985-01-01

    Machine outputs, peak scatter factors, and central axis percentage depth dose distributions were measured for various phantom sizes in large radiation fields produced at extended distances by cobalt, 6-MV, and 10-MV photon beams. The results can be applied to practical total body irradiation procedures which usually involve treatment volumes smaller than the actual field sizes in order to provide a uniform total body exposure to radiation. Our study addresses the question of the appropriate phantom dimension to be used in the calibration of photon beams employed in total body irradiations. The measurements show that the machine outputs are only slightly dependent on phantom size; the percentage depth dose distributions, however, are strongly dependent on the phantom size, suggesting that machine data for total body irradiations should be measured in phantoms whose dimensions approximate the patient during the total body irradiation. Peak scatter factors measured in large-field/small-phantom configurations link up well with the published small-field/large-phantom data. The finite patient thickness lowers the dose to points close to the beam exit surface by a few percent, when compared to dose measured at the same depths in infinitely thick phantoms. The surface doses in large radiation fields are essentially independent of phantom cross sections and range from 40% for the 10-MV beam, to 65% for the 6-MV beam and 80% for the cobalt beam

  11. Entrance surface dose measurements in mammography using thermoluminescence technique

    International Nuclear Information System (INIS)

    Rivera, T.; Vega C, H.R.; Manzanares A, E; Azorin, J.; Gonzalez, P.R.

    2007-01-01

    Full text: Of the various techniques that can be used for personnel dosimetry, thermoluminescence dosimetry (TLD) has emerged as a superior technique due to its manifold advantages over other methods of dose estimation. Various phosphors have been therefore investigated regarding their suitability for dosimetry. In this paper, a dosimetry system based on thermally stimulated luminescence (TSL) from zirconium oxide phosphors embedded in polytetrafluorethylene (ZrO 2 +PTFE) was developed for entrance surface doses (ES) measurements in mammography. Small ZrO 2 pellets of 5 mm in diameter and 0.8 mm in thickness were used. The reproducibility of measurements and linearity of ZrO 2 were also studied. The results were compared with those obtained from LiF:Mg,Cu,P usually used for the determination of absorbed dose in mammography. Measurements both per unit air kerma and In vivo were performed using a mammography unit model DMR (General Electric). The results showed that ZrO 2 TLDs can be used for the same X-ray dosimetry applications as LiF:Mg,Cu,P, with each type having the disadvantage of a response dependent on energy, particularly at low energies. These results indicate a considerable potential for use in routine control and In vivo ES measurements in mammography. (Author)

  12. Technical Note: Out-of-field dose measurement at near surface with plastic scintillator detector.

    Science.gov (United States)

    Bourgouin, Alexandra; Varfalvy, Nicolas; Archambault, Louis

    2016-09-08

    Out-of-field dose depends on multiple factors, making peripheral dosimetry com-plex. Only a few dosimeters have the required features for measuring peripheral dose. Plastic scintillator dosimeters (PSDs) offer numerous dosimetric advantages as required for out-of-field dosimetry. The purpose of this study is to determine the potential of using PSD as a surface peripheral dosimeter. Measurements were performed with a parallel-plate ion chamber, a small volume ion chamber, and with a PSD. Lateral-dose measurements (LDM) at 0.5 cm depth and depth-dose curve (PDD) were made and compared to the dose calculation provided by a treatment planning system (TPS). This study shows that a PSD can measure a dose as low as 0.51 ± 0.17 cGy for photon beam and 0.58 ± 0.20 cGy for electron beam with a difference of 0.2 and 0.1 cGy compared to a parallel-plate ion chamber. This study demonstrates the potential of using PSD as an out-of-field dosimeter since measure-ments with PSD avoid averaging over a too-large depth, at 1 mm diameter, and can make precise measurement at very low dose. Also, electronic equilibrium is easier to reach with PSD due to its small sensitive volume and its water equivalence. © 2016 The Authors.

  13. Low dose effect of bisphosphonates on hMSCs osteogenic response to titanium surface in vitro

    Directory of Open Access Journals (Sweden)

    N.R. Alqhtani

    2017-06-01

    Full Text Available Since the 1980s, titanium (Ti implants have been routinely used to replace missing teeth. This success is mainly due to the good biocompatibility of Ti and the phenomenon of osseointegration, with very early events at implant placement being important in determining good osseointegration. However, enhancing implant performance with coatings such as hydroxyapatite (HA and calcium phosphate has proved largely unsuccessful. Human mesenchymal stem cells (hMSCs are the first osteogenic cells to colonise implant surfaces and offer a target for enhancing osseointegration. We previously reported that small doses of bisphosphonate (BP may play an integral role in enhancing hMSC proliferation and osteogenic differentiation. The aim of this study is to investigate whether small doses of bisphosphonates enhance proliferation and osteogenic differentiation of hMSCs on Ti surfaces, to enhance bone osseointegration and to accelerate wound healing around the implant surface. Our data suggests that treating cells with small doses of BP (100 nM & 10 nM induces significant hMSC stimulation of osteogenic markers including calcium, collagen type I and ALP compared to control group on titanium surfaces (P < 0.05. In addition, cell proliferation and migration were significantly enhanced on titanium surfaces (P < 0.05.

  14. Entrance surface dose measurements in pediatric radiological examinations

    International Nuclear Information System (INIS)

    Ribeiro, L.A.; Yoshimura, E.M.

    2008-01-01

    A survey of pediatric radiological examinations was carried out in a reference pediatric hospital of the city of Sao Paulo, in order to investigate the doses to children undergoing conventional X-ray examinations. The results showed that the majority of pediatric patients are below 4 years, and that about 80% of the examinations correspond to chest projections. Doses to typical radiological examinations were measured in vivo with thermoluminescent dosimeters (LiF: Mg, Ti and LiF: Mg, Cu, P) attached to the skin of the children to determine entrance surface dose (ESD). Also homogeneous phantoms were used to obtain ESD to younger children, because the technique uses a so small kVp that the dosimeters would produce an artifact image in the patient radiograph. Four kinds of pediatric examinations were investigated: three conventional examinations (chest, skull and abdomen) and a fluoroscopic procedure (barium swallow). Relevant information about kVp and mAs values used in the examinations was collected, and we discuss how these parameters can affect the ESD. The ESD values measured in this work are compared to reference levels published by the European Commission for pediatric patients. The results obtained (third-quartile of the ESD distribution) for chest AP examinations in three age groups were: 0.056 mGy (2-4 years old); 0.068 mGy (5-9 years old); 0.069 mGy (10-15 years old). All of them are below the European reference level (0.100 mGy). ESD values measured to the older age group in skull and abdomen AP radiographs (mean values 3.44 and 1.20 mGy, respectively) are above the European reference levels (1.5 mGy to skull and 1.0 mGy to abdomen). ESD values measured in the barium swallow examination reached 10 mGy in skin regions corresponding to thyroid and esophagus. It was noticed during this survey that some technicians use, improperly, X-ray fluoroscopy in conventional examinations to help them in positioning the patient. The results presented here are a

  15. Surface sputtering in high-dose Fe ion implanted Si

    International Nuclear Information System (INIS)

    Ishimaru, Manabu

    2007-01-01

    Microstructures and elemental distributions in high-dose Fe ion implanted Si were characterized by means of transmission electron microscopy and Rutherford backscattering spectroscopy. Single crystalline Si(0 0 1) substrates were implanted at 350 deg. C with 120 keV Fe ions to fluences ranging from 0.1 x 10 17 to 4.0 x 10 17 /cm 2 . Extensive damage induced by ion implantation was observed inside the substrate below 1.0 x 10 17 /cm 2 , while a continuous iron silicide layer was formed at 4.0 x 10 17 /cm 2 . It was found that the spatial distribution of Fe projectiles drastically changes at the fluence between 1.0 x 10 17 and 4.0 x 10 17 /cm 2 due to surface sputtering during implantation

  16. Entrance surface dose in cerebral interventional radiology procedures

    International Nuclear Information System (INIS)

    Barrera-Rico, M.; López-Rendón, X.; Rivera-Ordóñez, C. E.; Gamboa-deBuen, I.

    2012-01-01

    At the Instituto Nacional de Neurología y Neurocirugía (INNN) diagnostic as well as therapeutic procedures of interventional radiology are carried out. Since the procedures can last from some minutes to several hours, the absorbed dose for the patient could increase dangerously. An investigation had begun in order to determine the entrance surface dose (ESD) using 25 thermoluminiscent dosimeters TLD-100 and 8 strips of 15 ×1 cm 2 of Gafchromic XR-QA2 film bound in a holder of 15×15 cm 2 in the posteroanterior (PA) and lateral (LAT) positions during all the procedure. The results show that maximum ESD could be from 0.9 to 2.9 Gy for the PA position and between 1.6 and 2.5 Gy for the lateral position. The average ESD was between 0.7 and 1.3 Gy for the PA position, and from 0.44 to 1.1 Gy for the lateral position in a therapeutic procedure.

  17. Entrance surface dose in cerebral interventional radiology procedures

    Energy Technology Data Exchange (ETDEWEB)

    Barrera-Rico, M.; Lopez-Rendon, X.; Rivera-Ordonez, C. E.; Gamboa-deBuen, I. [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, 04510 DF (Mexico); Instituto Nacional de Neurologia y Neurocirugia Manuel Velasco Suarez, 14269 DF (Mexico); Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, 04510 DF (Mexico)

    2012-10-23

    At the Instituto Nacional de Neurologia y Neurocirugia (INNN) diagnostic as well as therapeutic procedures of interventional radiology are carried out. Since the procedures can last from some minutes to several hours, the absorbed dose for the patient could increase dangerously. An investigation had begun in order to determine the entrance surface dose (ESD) using 25 thermoluminiscent dosimeters TLD-100 and 8 strips of 15 Multiplication-Sign 1 cm{sup 2} of Gafchromic XR-QA2 film bound in a holder of 15 Multiplication-Sign 15 cm{sup 2} in the posteroanterior (PA) and lateral (LAT) positions during all the procedure. The results show that maximum ESD could be from 0.9 to 2.9 Gy for the PA position and between 1.6 and 2.5 Gy for the lateral position. The average ESD was between 0.7 and 1.3 Gy for the PA position, and from 0.44 to 1.1 Gy for the lateral position in a therapeutic procedure.

  18. The survey of the surface doses of the dental x-ray machines

    International Nuclear Information System (INIS)

    Lee, Jae Seo; Kang, Byung Cheol; Yoon, Suk Ja

    2005-01-01

    The purpose of this study was to investigate variability of doses with same exposure parameters and evaluate radiographic density according to the variability of doses. Twenty-eight MAX-GLS (Shinhung Co, Seoul, Korea), twenty-one D-60-S (DongSeo Med, Seoul, Korea), and eleven REX-601 (Yoshida Dental MFG, Tokyo, Japan) dental x-ray machines were selected for this study. Surface doses were measured under selected combinations of tube voltage, tube current, exposure time, and constant distance 42 cm from the focal spot to the surface of the Multi-O-meter (Unfors Instrument, Billdal, Sweden). Radiographic densities were measured on the films at maximum, minimum and mean surface doses of each brand of x-ray units. With MAX-GLS, the maximum surface doses were thirteen to fourteen times as much as the minimum surfaces doses. With D-60-S, the maximum surface doses were three to eight times as much as the minimum surface doses. With REX-601, the maximum surface doses were six to ten times as much as the minimum surface doses. The differences in radiographic densities among maximum, mean, and minimum doses were significant (p<0.01). The surface exposure doses of each x-ray machine at the same exposure parameters were different within the same manufacturer's machines.

  19. Calculation of Organ Doses for a Large Number of Patients Undergoing CT Examinations.

    Science.gov (United States)

    Bahadori, Amir; Miglioretti, Diana; Kruger, Randell; Flynn, Michael; Weinmann, Sheila; Smith-Bindman, Rebecca; Lee, Choonsik

    2015-10-01

    The objective of our study was to develop an automated calculation method to provide organ dose assessment for a large cohort of pediatric and adult patients undergoing CT examinations. We adopted two dose libraries that were previously published: the volume CT dose index-normalized organ dose library and the tube current-exposure time product (100 mAs)-normalized weighted CT dose index library. We developed an algorithm to calculate organ doses using the two dose libraries and the CT parameters available from DICOM data. We calculated organ doses for pediatric (n = 2499) and adult (n = 2043) CT examinations randomly selected from four health care systems in the United States and compared the adult organ doses with the values calculated from the ImPACT calculator. The median brain dose was 20 mGy (pediatric) and 24 mGy (adult), and the brain dose was greater than 40 mGy for 11% (pediatric) and 18% (adult) of the head CT studies. Both the National Cancer Institute (NCI) and ImPACT methods provided similar organ doses (median discrepancy variety of CT-related studies including retrospective epidemiologic studies and CT dose trend analysis studies.

  20. Impact of source position on high-dose-rate skin surface applicator dosimetry.

    Science.gov (United States)

    Jeong, Jeho; Barker, Christopher A; Zaider, Marco; Cohen, Gil'ad N

    2016-01-01

    Skin surface dosimetric discrepancies between measured and treatment planning system predicted values were traced to source position sag inside the applicator and to source transit time. We quantified their dosimetric impact and propose corrections for clinical use. We measured the dose profiles from the Varian Leipzig-style high-dose-rate (HDR) skin applicator, using EBT3 film, photon diode, and optically stimulated luminescence dosimeter for three different GammaMedplus HDR afterloaders. The measured dose profiles at several depths were compared with BrachyVision Acuros calculated profiles. To assess the impact of the source sag, two different applicator orientations were considered. The dose contribution during source transit was assessed by comparing diode measurements using an HDR timer and an electrometer timer. Depth doses measured using the three dosimeters were in good agreement, but were consistently higher than the Acuros dose calculations. Measurements with the applicator face up were significantly (exceeding 10%) lower than those in the face down position, due to source sag inside the applicator. Based on the inverse square law, the effective source sag was evaluated to be about 0.5 mm from the planned position. The additional dose during source transit was evaluated to be about 2.8% for 30 seconds of treatment with a 40700 U (10 Ci) source. With a very short source-to-surface distance, the small source sag inside the applicator has a significant dosimetric impact. This effect is unaccounted for in the vendor's treatment planning template and should be considered before the clinical use of the applicator. Further investigation of other applicators with large source lumen diameter may be warranted. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  1. Analysis on the entrance surface dose and contrast medium dose at computed tomography and angiography in cardiovascular examination

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Young Hyun [Dept. of Cardiovascular Center, Yeocheon Jeonnam Hospital, Yeosu (Korea, Republic of); Han, Jae Bok; Choi, Nam Gil; Song, Jong Nam [Dept. of Radiological Science, Dongshin University, Naju (Korea, Republic of)

    2016-12-15

    This study aimed to identify dose reduction measures by retrospectively analyzing the entrance surface dose at computed tomography and angiography in cardiovascular examination and to contribute the patients with renal impairmend and a high probability of side effects to determine the inspection's direction by measuring the contrast usages actually to active actions for the dose by actually measuring the contrast medium dose. The CTDIvol value and air kerma value, which are the entrance surface doses of the two examinations, and the contrast medium dose depending on the number of slides were compared and analyzed. This study was conducted in 21 subjects (11 males; 10 females) who underwent Cardiac Computed Tomographic Angiography (CCTA) and Coronary Angiography (CAG) in this hospital during the period from May 2014 to May 2016. The subject's age was 48-85 years old (mean 65±10 years old), and the weight was 37.6~83.3 kg (mean 63±6 kg). Dose reduction could be expected in the cardiovascular examination using CCTA rather than in the examination using CAG. In terms of contrast medium dose, CAG used a smaller dose than CCTA. In particular, as the number of slides increases at CAG, the contrast medium dose increases. Therefore, in order to reduce the contrast medium dose, the number of slides suitable for the scan range must be selected.

  2. Active Surface Compensation for Large Radio Telescope Antennas

    Science.gov (United States)

    Wang, Congsi; Li, Haihua; Ying, Kang; Xu, Qian; Wang, Na; Duan, Baoyan; Gao, Wei; Xiao, Lan; Duan, Yuhu

    2018-03-01

    With the development of radio telescope antennas with large apertures, high gain, and wide frequency bands, compensation methods, such as mechanical or electronic compensation, are obviously essential to ensure the electrical performance of antennas that work in complex environments. Since traditional compensation methods can only adjust antenna pointing but not the surface accuracy, which are limited for obtaining high surface precision and aperture efficiency, active surface adjustment has become an indispensable tool in this field. Therefore, the development process of electrical performance compensation methods for radio telescope antennas is introduced. Further, a series of analyses of the five key technologies of active surface adjustment is presented. Then, four typical large antennas that have been designed with active main reflector technology are presented and compared. Finally, future research directions and suggestions for reflector antenna compensation method! s based on active surface adjustment are presented.

  3. Dose contributions from large-angle scattered particles in therapeutic carbon beams

    International Nuclear Information System (INIS)

    Kusano, Yohsuke; Kanai, Tatsuaki; Kase, Yuki; Matsufuji, Naruhiro; Komori, Masataka; Kanematsu, Nobuyuki; Ito, Atsushi; Uchida, Hirohisa

    2007-01-01

    In carbon therapy, doses at center of spread-out Bragg peaks depend on field size. For a small field of 5x5 cm 2 , the central dose reduces to 96% of the central dose for the open field in case of 400 MeV/n carbon beam. Assuming the broad beam injected to the water phantom is made up of many pencil beams, the transverse dose distribution can be reconstructed by summing the dose distribution of the pencil beams. We estimated dose profiles of this pencil beam through measurements of dose distributions of broad uniform beams blocked half of the irradiation fields. The dose at a distance of a few cm from the edge of the irradiation field reaches up to a few percent of the central dose. From radiation quality measurements of this penumbra, the large-angle scattered particles were found to be secondary fragments which have lower LET than primary carbon beams. Carbon ions break up in beam modifying devices or in water phantom through nuclear interaction with target nuclei. The angular distributions of these fragmented nuclei are much broader than those of primary carbon particles. The transverse dose distribution of the pencil beam can be approximated by a function of the three-Gaussian form. For a simplest case of mono-energetic beam, contributions of the Gaussian components which have large mean deviations become larger as the depth in the water phantom increases

  4. Estimates of Radiation Dose Rates Near Large Diameter Sludge Containers in T Plant

    CERN Document Server

    Himes, D A

    2002-01-01

    Dose rates in T Plant canyon during the handling and storage of large diameter storage containers of K Basin sludge were estimated. A number of different geometries were considered from which most operational situations of interest can be constructed.

  5. Use of the LQ model with large fraction sizes results in underestimation of isoeffect doses

    International Nuclear Information System (INIS)

    Sheu, Tommy; Molkentine, Jessica; Transtrum, Mark K.; Buchholz, Thomas A.; Withers, Hubert Rodney; Thames, Howard D.; Mason, Kathy A.

    2013-01-01

    Purpose: To test the appropriateness of the linear-quadratic (LQ) model to describe survival of jejunal crypt clonogens after split doses with variable (small 1–6 Gy, large 8–13 Gy) first dose, as a model of its appropriateness for both small and large fraction sizes. Methods: C3Hf/KamLaw mice were exposed to whole body irradiation using 300 kVp X-rays at a dose rate of 1.84 Gy/min, and the number of viable jejunal crypts was determined using the microcolony assay. 14 Gy total dose was split into unequal first and second fractions separated by 4 h. Data were analyzed using the LQ model, the lethal potentially lethal (LPL) model, and a repair-saturation (RS) model. Results: Cell kill was greater in the group receiving the larger fraction first, creating an asymmetry in the plot of survival vs size of first dose, as opposed to the prediction of the LQ model of a symmetric response. There was a significant difference in the estimated βs (higher β after larger first doses), but no significant difference in the αs, when large doses were given first vs small doses first. This difference results in underestimation (based on present data by approximately 8%) of isoeffect doses using LQ model parameters based on small fraction sizes. While the LPL model also predicted a symmetric response inconsistent with the data, the RS model results were consistent with the observed asymmetry. Conclusion: The LQ model underestimates doses for isoeffective crypt-cell survival with large fraction sizes (in the present setting, >9 Gy)

  6. Surface barrier silicon detectors with a large active area

    International Nuclear Information System (INIS)

    Kim, Y.; Husimi, K.; Ikeda, Y.; Kim, C.; Ohkawa, S.; Sakai, T.

    1985-01-01

    Surface barrier silicon detectors with a large active area have been produced by using high resistive n-type silicon crystals, diameters of which are 3 to 5 inches. High quality detectors with a low leakage current and a low noise were achieved by developing the improved surface treatment. Characteristics of detectors obtained are good in energy resolution compared with conventional large area Si(Li) detectors. It has also been confirmed that local dead region is not found from measuring results of photo-pulse injection

  7. Predicting Surface Runoff from Catchment to Large Region

    Directory of Open Access Journals (Sweden)

    Hongxia Li

    2015-01-01

    Full Text Available Predicting surface runoff from catchment to large region is a fundamental and challenging task in hydrology. This paper presents a comprehensive review for various studies conducted for improving runoff predictions from catchment to large region in the last several decades. This review summarizes the well-established methods and discusses some promising approaches from the following four research fields: (1 modeling catchment, regional and global runoff using lumped conceptual rainfall-runoff models, distributed hydrological models, and land surface models, (2 parameterizing hydrological models in ungauged catchments, (3 improving hydrological model structure, and (4 using new remote sensing precipitation data.

  8. Moving gantry method for electron beam dose profile measurement at extended source-to-surface distances.

    Science.gov (United States)

    Fekete, Gábor; Fodor, Emese; Pesznyák, Csilla

    2015-03-08

    A novel method has been put forward for very large electron beam profile measurement. With this method, absorbed dose profiles can be measured at any depth in a solid phantom for total skin electron therapy. Electron beam dose profiles were collected with two different methods. Profile measurements were performed at 0.2 and 1.2 cm depths with a parallel plate and a thimble chamber, respectively. 108cm × 108 cm and 45 cm × 45 cm projected size electron beams were scanned by vertically moving phantom and detector at 300 cm source-to-surface distance with 90° and 270° gantry angles. The profiles collected this way were used as reference. Afterwards, the phantom was fixed on the central axis and the gantry was rotated with certain angular steps. After applying correction for the different source-to-detector distances and incidence of angle, the profiles measured in the two different setups were compared. Correction formalism has been developed. The agreement between the cross profiles taken at the depth of maximum dose with the 'classical' scanning and with the new moving gantry method was better than 0.5 % in the measuring range from zero to 71.9 cm. Inverse square and attenuation corrections had to be applied. The profiles measured with the parallel plate chamber agree better than 1%, except for the penumbra region, where the maximum difference is 1.5%. With the moving gantry method, very large electron field profiles can be measured at any depth in a solid phantom with high accuracy and reproducibility and with much less time per step. No special instrumentation is needed. The method can be used for commissioning of very large electron beams for computer-assisted treatment planning, for designing beam modifiers to improve dose uniformity, and for verification of computed dose profiles.

  9. Power Spectral Density Specification and Analysis of Large Optical Surfaces

    Science.gov (United States)

    Sidick, Erkin

    2009-01-01

    The 2-dimensional Power Spectral Density (PSD) can be used to characterize the mid- and the high-spatial frequency components of the surface height errors of an optical surface. We found it necessary to have a complete, easy-to-use approach for specifying and evaluating the PSD characteristics of large optical surfaces, an approach that allows one to specify the surface quality of a large optical surface based on simulated results using a PSD function and to evaluate the measured surface profile data of the same optic in comparison with those predicted by the simulations during the specification-derivation process. This paper provides a complete mathematical description of PSD error, and proposes a new approach in which a 2-dimentional (2D) PSD is converted into a 1-dimentional (1D) one by azimuthally averaging the 2D-PSD. The 1D-PSD calculated this way has the same unit and the same profile as the original PSD function, thus allows one to compare the two with each other directly.

  10. Maximum skin dose assessment in interventional cardiology: large area detectors and calculation methods

    International Nuclear Information System (INIS)

    Quail, E.; Petersol, A.

    2002-01-01

    Advances in imaging technology have facilitated the development of increasingly complex radiological procedures for interventional radiology. Such interventional procedures can involve significant patient exposure, although often represent alternatives to more hazardous surgery or are the sole method for treatment. Interventional radiology is already an established part of mainstream medicine and is likely to expand further with the continuing development and adoption of new procedures. Between all medical exposures, interventional radiology is first of the list of the more expansive radiological practice in terms of effective dose per examination with a mean value of 20 mSv. Currently interventional radiology contribute 4% to the annual collective dose, in spite of contributing to total annual frequency only 0.3% but considering the perspectives of this method can be expected a large expansion of this value. In IR procedures the potential for deterministic effects on the skin is a risk to be taken into account together with stochastic long term risk. Indeed, the International Commission on Radiological Protection (ICRP) in its publication No 85, affirms that the patient dose of priority concern is the absorbed dose in the area of skin that receives the maximum dose during an interventional procedure. For the mentioned reasons, in IR it is important to give to practitioners information on the dose received by the skin of the patient during the procedure. In this paper maximum local skin dose (MSD) is called the absorbed dose in the area of skin receiving the maximum dose during an interventional procedure

  11. Evaluation of the Entrance Surface Dose (ESD and Radiation Dose to the Radiosensitive Organs in Pediatric Pelvic Radiography

    Directory of Open Access Journals (Sweden)

    Vahid Karami

    2017-06-01

    Full Text Available Background Patients' dosimetry is crucial in order to enhance radiation protection optimization and to deliver low radiation dose to the patients in a radiological procedure. The aim of this study was to assess the entrance surface dose (ESD and radiation dose to the radiosensitive organs in pediatric pelvic radiography. Materials and Methods The studied population included 98 pediatric patients of both genders referred to anteroposterior (AP projection of pelvic radiography. The radiation dose was directly measured using high radiosensitive cylindrical lithium fluoride thermo-luminescent dosimeters (TLD-GR200. Two TLDs were placed at the center point of the radiation field to measure the ESD of pelvis. Moreover for each patient, 2 TLDs were placed upon each eyelid, 2 TLDs upon each breast, 2 TLDs upon the surface anatomical position of the thyroid gland and finally 2 TLDs at the surface anatomical position of the gonads to measure the received dose. Results The ESD ± standard deviation for AP pelvic radiography was obtained 591.7±76 µGy. Statistically significant difference was obtained between organs located outside and inside of the radiation field with respect to dose received (P

  12. Multispectral Acquisition of Large-Sized Pictorial Surfaces

    Directory of Open Access Journals (Sweden)

    Paviotti Anna

    2009-01-01

    Full Text Available Multispectral acquisition of artworks has recently received considerable attention in the image processing community. Quite understandably, so far this attention has mainly focused on paintings, given their predominant role in museum collections. It is worth pointing out that the instrumentation and procedures used for acquiring regular paintings are not suited for the multispectral acquisition of large-sized painted surfaces such as frescoed halls and great paintings. Given the relevance of such artifacts, and their widespread presence in churches or historical buildings due to their social function, the problem of finding suitable techniques for their acquisition is certainly worth addressing. This paper focuses on multispectral acquisition of large-sized pictorial surfaces, systematically addressing the practical issues related to the acquisition equipment and procedure. Given the crucial role played by the illumination in this application, special attention is given to this issue. The proposed approach is supported by experimental results.

  13. Behavior of plasma facing surface in the large helical device

    International Nuclear Information System (INIS)

    Hino, T.; Nobuta, Y.; Sagara, A.

    2002-01-01

    Material probes have been installed at the inner walls along poloidal direction in LHD from the first experimental campaign. After each campaign, the impurity deposition and the gas retention have been examined to clarify the plasma surface interaction and the degree of wall cleaning. In the 2nd campaign, the entire wall was considerably cleaned by helium glow discharge conditionings. For the 3rd and 4th campaigns, graphite tiles were installed at entire divertor strike region, and then the wall condition significantly changed compared to the case of stainless steel wall. The erosion of graphite took place during the main discharges and the eroded carbon deposited on the entire wall. In particular, the deposition thickness was large at the wall far from the plasma. Since the entire wall was well carbonized, amount of retained discharge gas such as H and He became large. In particular, the helium retention was large at the position close to the anodes used for helium glow discharge cleanings. One characteristics of the LHD wall is a large retention of helium gas since the wall temperature is limited below 368 K. In order to reduce the recycling of discharge gas, the wall heating before the experimental campaign and the surface heating between the main discharge shots are planned. (author)

  14. Behavior of plasma facing surfaces in the large helical device

    International Nuclear Information System (INIS)

    Hino, T.; Nobuta, Y.; Sagara, A.

    2003-01-01

    Material probes have been installed at the inner walls along the poloidal direction in LHD from the first experimental campaign. After each campaign, the impurity deposition and the gas retention have been examined to clarify the plasma surface interaction and the degree of wall cleaning. In the 2nd campaign, the entire wall was thoroughly cleaned by helium glow discharge conditioning. For the 3rd and 4th campaigns, graphite tiles were installed over the entire divertor strike region, and then the wall condition was significantly changed compared to the case of a stainless steel wall. Graphite erosion took place during the main discharges and the eroded carbon was deposited on the entire wall. In particular, the deposition thickness was large at the wall far from the plasma. Since the entire wall was well carbonized, the amount of retained discharge gases such as H and He became large. In particular, the helium retention was large at the position close to the anodes used for helium glow discharge cleanings. One characteristic of the LHD wall is a large retention of helium gas since the wall temperature is limited to below 368 K. In order to reduce the recycling of discharge gas, wall heating before the experimental campaign and surface heating between the main discharge shots are planned. (author)

  15. Behavior of plasma facing surface in the large helical device

    International Nuclear Information System (INIS)

    Hino, T.; Nobuta, Y.; Sagara, A.

    2002-10-01

    Material probes have been installed at the inner walls along poloidal direction in LHD from the first experimental campaign. After each the campaign, the impurity deposition and the gas retention have been examined to clarify the plasma surface interaction and the degree of wall cleaning. In the 2nd campaign, the entire wall was considerably cleaned by helium glow discharge conditionings. For the 3rd and 4th campaigns, graphite tiles were installed at entire divertor strike region, and then the wall condition significantly changed compared to the case of stainless steel wall. The erosion of graphite took place during the main discharges and the eroded carbon deposited on the entire wall. In particular, the deposition thickness was large at the wall far from the plasma. Since the entire wall was well carbonized, amount of retained discharge gas such as H and He became large. In particular, the helium retention was large at the position close to the anodes used for helium glow discharge cleanings. One characteristics of the LHD wall is a large retention of helium gas since the wall temperature is limited below 368 K. In order to reduce the recycling of discharge gas, the wall heating before the experimental campaign and the surface heating between the main discharge shots are planned. (author)

  16. Behavior of plasma facing surface in the large helical device

    Energy Technology Data Exchange (ETDEWEB)

    Hino, T.; Nobuta, Y. [Hokkaido Univ., Dept. of Nuclear Engineering, Sapporo, Hokkaido (Japan); Sagara, A. [National Inst. for Fusion Science, Toki, Gifu (Japan)] [and others

    2002-11-01

    Material probes have been installed at the inner walls along poloidal direction in LHD from the first experimental campaign. After each campaign, the impurity deposition and the gas retention have been examined to clarify the plasma surface interaction and the degree of wall cleaning. In the 2nd campaign, the entire wall was considerably cleaned by helium glow discharge conditionings. For the 3rd and 4th campaigns, graphite tiles were installed at entire divertor strike region, and then the wall condition significantly changed compared to the case of stainless steel wall. The erosion of graphite took place during the main discharges and the eroded carbon deposited on the entire wall. In particular, the deposition thickness was large at the wall far from the plasma. Since the entire wall was well carbonized, amount of retained discharge gas such as H and He became large. In particular, the helium retention was large at the position close to the anodes used for helium glow discharge cleanings. One characteristics of the LHD wall is a large retention of helium gas since the wall temperature is limited below 368 K. In order to reduce the recycling of discharge gas, the wall heating before the experimental campaign and the surface heating between the main discharge shots are planned. (author)

  17. Two large preoperative doses of erythropoietin do not reduce the systemic inflammatory response to cardiac surgery

    DEFF Research Database (Denmark)

    Poulsen, Troels Dirch; Andersen, Lars Willy; Steinbrüchel, Daniel

    2009-01-01

    . This study tested the hypothesis that 2 large doses of EPO administered shortly before CPB ameliorate the systemic inflammatory response to CPB. DESIGN AND SETTING: A prospective, double-blind, placebo-controlled and randomized study at a single tertiary care hospital. PARTICIPANTS: Patients scheduled...

  18. Influence of standard RF coil materials on surface and buildup dose from a 6 MV photon beam in magnetic field.

    Science.gov (United States)

    Ghila, A; Fallone, B G; Rathee, S

    2016-11-01

    magnetic field, the surface dose reduction was more rapid reaching a dose level of 30%-40% with only 3-4 cm gap. In the presence of the parallel magnetic field, as expected, the surface dose did not decrease considerably as the gap between the phantom surface and test materials was increased; the surface dose remained >60% at 10 cm gap for all tested materials except for the thin copper conductor. As expected, placing coil materials in direct contact with the phantom surface increases the surface dose considerably. The surface dose is reduced by creating a gap between the coil materials and phantom surface. This dose reduction happens more rapidly in the presence of a transverse magnetic field. However, the surface dose stays relatively large irrespective of the gap in the presence of a parallel magnetic field. Thus, the standard, off-the-shelf RF coils should be used with caution in integrated linac-MR systems, especially those using a parallel magnetic field orientation in which case the RF coils will probably need to be reconfigured to create open ports for the radiation beam.

  19. Exposing earth surface process model simulations to a large audience

    Science.gov (United States)

    Overeem, I.; Kettner, A. J.; Borkowski, L.; Russell, E. L.; Peddicord, H.

    2015-12-01

    The Community Surface Dynamics Modeling System (CSDMS) represents a diverse group of >1300 scientists who develop and apply numerical models to better understand the Earth's surface. CSDMS has a mandate to make the public more aware of model capabilities and therefore started sharing state-of-the-art surface process modeling results with large audiences. One platform to reach audiences outside the science community is through museum displays on 'Science on a Sphere' (SOS). Developed by NOAA, SOS is a giant globe, linked with computers and multiple projectors and can display data and animations on a sphere. CSDMS has developed and contributed model simulation datasets for the SOS system since 2014, including hydrological processes, coastal processes, and human interactions with the environment. Model simulations of a hydrological and sediment transport model (WBM-SED) illustrate global river discharge patterns. WAVEWATCH III simulations have been specifically processed to show the impacts of hurricanes on ocean waves, with focus on hurricane Katrina and super storm Sandy. A large world dataset of dams built over the last two centuries gives an impression of the profound influence of humans on water management. Given the exposure of SOS, CSDMS aims to contribute at least 2 model datasets a year, and will soon provide displays of global river sediment fluxes and changes of the sea ice free season along the Arctic coast. Over 100 facilities worldwide show these numerical model displays to an estimated 33 million people every year. Datasets storyboards, and teacher follow-up materials associated with the simulations, are developed to address common core science K-12 standards. CSDMS dataset documentation aims to make people aware of the fact that they look at numerical model results, that underlying models have inherent assumptions and simplifications, and that limitations are known. CSDMS contributions aim to familiarize large audiences with the use of numerical

  20. A consideration on internal dose evaluation and intervention based on a surface contamination concept

    International Nuclear Information System (INIS)

    Yasuda, H.

    1997-01-01

    Long-term radiation doses received by the inhabitants after the Chernobyl accident have been evaluated according to the surface contamination levels on the ground surface. The health effects have also been discussed by comparison between the surface-contaminated area and the uncontaminated control area. Selected protective measures were carried out in accordance with the contamination level of surface soil. These have been based on the 'surface contamination concept' which assumes that the radiation risk to inhabitants is proportional to the level of ground-surface contamination. The observations collected in regions around Chernobyl, however, show that the internal radiation doses to the inhabitants poorly correlate with the surface contamination level. This fact poses a question on the suitability of dose evaluations and interventions based on this concept

  1. Large Rashba spin splitting of a metallic surface-state band on a semiconductor surface

    Science.gov (United States)

    Yaji, Koichiro; Ohtsubo, Yoshiyuki; Hatta, Shinichiro; Okuyama, Hiroshi; Miyamoto, Koji; Okuda, Taichi; Kimura, Akio; Namatame, Hirofumi; Taniguchi, Masaki; Aruga, Tetsuya

    2010-01-01

    The generation of spin-polarized electrons at room temperature is an essential step in developing semiconductor spintronic applications. To this end, we studied the electronic states of a Ge(111) surface, covered with a lead monolayer at a fractional coverage of 4/3, by angle-resolved photoelectron spectroscopy (ARPES), spin-resolved ARPES and first-principles electronic structure calculation. We demonstrate that a metallic surface-state band with a dominant Pb 6p character exhibits a large Rashba spin splitting of 200 meV and an effective mass of 0.028 me at the Fermi level. This finding provides a material basis for the novel field of spin transport/accumulation on semiconductor surfaces. Charge density analysis of the surface state indicated that large spin splitting was induced by asymmetric charge distribution in close proximity to the nuclei of Pb atoms. PMID:20975678

  2. Large chiral diffeomorphisms on Riemann surfaces and W-algebras

    International Nuclear Information System (INIS)

    Bandelloni, G.; Lazzarini, S.

    2006-01-01

    The diffeomorphism action lifted on truncated (chiral) Taylor expansion of a complex scalar field over a Riemann surface is presented in the paper under the name of large diffeomorphisms. After an heuristic approach, we show how a linear truncation in the Taylor expansion can generate an algebra of symmetry characterized by some structure functions. Such a linear truncation is explicitly realized by introducing the notion of Forsyth frame over the Riemann surface with the help of a conformally covariant algebraic differential equation. The large chiral diffeomorphism action is then implemented through a Becchi-Rouet-Stora (BRS) formulation (for a given order of truncation) leading to a more algebraic setup. In this context the ghost fields behave as holomorphically covariant jets. Subsequently, the link with the so-called W-algebras is made explicit once the ghost parameters are turned from jets into tensorial ghost ones. We give a general solution with the help of the structure functions pertaining to all the possible truncations lower or equal to the given order. This provides another contribution to the relationship between Korteweg-de Vries (KdV) flows and W-diffeomorphims

  3. Pathomorphology of spleen lymphocyte apoptosis in large dose 60Co γ-irradiated mice

    International Nuclear Information System (INIS)

    Gao Linlu; Cui Yufang; Yang Hong; Xia Guowei; Peng Ruiyun; Gao Yabing; Wang Dewen

    2000-01-01

    Objective: The aim of the authors was to investigate the pathomorphology changes of spleen lymphocyte apoptosis after 60 Co γ-irradiation. Methods: The mice were irradiated with 6, 9, 12, 15 and 20 Gy of 60 Co γ-rays. At different times after irradiation, the mice were sacrificed and the pathological changes of spleen lymphocyte were observed by light and transmission electron microscopies. Results: Spleen lymphocyte decreased evidently and the peak of apoptosis in spleen lymphocyte was dependent on radiation dose and the time after irradiation. Conclusion: After γ-irradiation with large doses, pathological changes of spleen lymphocyte apoptosis in mice can be divided into obviously different stages. The main causes of death of spleen lymphocytes are different in different dose groups

  4. Validating modeled turbulent heat fluxes across large freshwater surfaces

    Science.gov (United States)

    Lofgren, B. M.; Fujisaki-Manome, A.; Gronewold, A.; Anderson, E. J.; Fitzpatrick, L.; Blanken, P.; Spence, C.; Lenters, J. D.; Xiao, C.; Charusambot, U.

    2017-12-01

    Turbulent fluxes of latent and sensible heat are important physical processes that influence the energy and water budgets of the Great Lakes. Validation and improvement of bulk flux algorithms to simulate these turbulent heat fluxes are critical for accurate prediction of hydrodynamics, water levels, weather, and climate over the region. Here we consider five heat flux algorithms from several model systems; the Finite-Volume Community Ocean Model, the Weather Research and Forecasting model, and the Large Lake Thermodynamics Model, which are used in research and operational environments and concentrate on different aspects of the Great Lakes' physical system, but interface at the lake surface. The heat flux algorithms were isolated from each model and driven by meteorological data from over-lake stations in the Great Lakes Evaporation Network. The simulation results were compared with eddy covariance flux measurements at the same stations. All models show the capacity to the seasonal cycle of the turbulent heat fluxes. Overall, the Coupled Ocean Atmosphere Response Experiment algorithm in FVCOM has the best agreement with eddy covariance measurements. Simulations with the other four algorithms are overall improved by updating the parameterization of roughness length scales of temperature and humidity. Agreement between modelled and observed fluxes notably varied with geographical locations of the stations. For example, at the Long Point station in Lake Erie, observed fluxes are likely influenced by the upwind land surface while the simulations do not take account of the land surface influence, and therefore the agreement is worse in general.

  5. Comparison of skin doses to large fields using tangential beams from cobalt-60 gamma rays and 4-MV x rays

    International Nuclear Information System (INIS)

    Gagnon, W.F.; Peterson, M.D.

    1978-01-01

    Excess radiation to the skin during external beam megavoltage radiation therapy has reportedly caused excessive erythema in patients treated with the Clinac 4 linear accelerator on sloping surfaces, but not for similar treatments with cobalt-60. Doses at the epidermal level were measured under geometries simulating sloping surfaces for a Clinac 4 and an Eldorado 8 cobalt-60 teletherapy machine. For equal doses to the axilla, doses to the epidermal layer were similar. When the tumor dose was calculated for the mediastinum, the dose to the skin in the axillary region was 12% higher for the Clinac 4

  6. Validation of a large-scale audit technique for CT dose optimisation

    International Nuclear Information System (INIS)

    Wood, T. J.; Davis, A. W.; Moore, C. S.; Beavis, A. W.; Saunderson, J. R.

    2008-01-01

    The expansion and increasing availability of computed tomography (CT) imaging means that there is a greater need for the development of efficient optimisation strategies that are able to inform clinical practice, without placing a significant burden on limited departmental resources. One of the most fundamental aspects to any optimisation programme is the collection of patient dose information, which can be compared with appropriate diagnostic reference levels. This study has investigated the implementation of a large-scale audit technique, which utilises data that already exist in the radiology information system, to determine typical doses for a range of examinations on four CT scanners. This method has been validated against what is considered the 'gold standard' technique for patient dose audits, and it has been demonstrated that results equivalent to the 'standard-sized patient' can be inferred from this much larger data set. This is particularly valuable where CT optimisation is concerned as it is considered a 'high dose' technique, and hence close monitoring of patient dose is particularly important. (authors)

  7. Electromagnetic surface waves for large-area RF plasma productions between large-area planar electrodes

    International Nuclear Information System (INIS)

    Nonaka, S.

    1992-01-01

    Recently, large-area plasma production has been tested by means of a 13.56 MHz radio-frequency (RF) discharge between a pair of large-area planar electrodes, approximately 0.5 m x 1.4 m, as one of the semiconductor technologies for fabrication of large-area amorphous silicon solar cells in the ''Sunshine Project'' of the Agency of Industrial Science and Technology in Japan. We also confirmed long plasma production between a pair of long electrodes. In this paper, normal electromagnetic (EM) waves propagating in a region between a planar waveguide with one plasma and two dielectric layers are analyzed in order to study the feasibility of large-area plasma productions by EM wave-discharges between a pair of large-area RF electrodes larger than the half-wavelength of RF wave. In conclusion, plasmas higher than an electron plasma frequency will be produced by an odd TMoo surface mode. (author) 4 refs., 3 figs

  8. Radiolysis of aqueous solutions of ammonium bicarbonate over a large dose range

    International Nuclear Information System (INIS)

    Draganic, Z.D.; Negron-Mendoza, A.; Vujosevic, S.I.; Navarro-Gonzales, R.; Albarran-Sanchez, M.G.

    1991-01-01

    Oxygen-free aqueous solutions of 0.05 mol dm -3 ammonium and sodium bicarbonate were studied after receiving various doses of 60 Co gammas (0.01-400 kGy) or 0.5-20 Gy pulses of 10 Mev electrons. Formate and oxalate were found to be the main radiolytic products, in addition to trace amounts of formaldehyde and an unidentified polymer. A large initial yield of formate in the γ-radiolysis, G(HCOO - ) = 2.2, is due to the reaction COO - + HCO 3 - ↔ HCOO - +CO 3 - . The efficiency of organic synthesis within the large dose range studied is low and is explained by efficient pathways leading to the reformation of bicarbonate, where the reaction COO - + CO 3 - is particularly significant. (author)

  9. Accidental intravenous infusion of a large dose of magnesium sulphate during labor: A case report

    Directory of Open Access Journals (Sweden)

    Kamal Kumar

    2013-01-01

    Full Text Available During labor and child delivery, a wide range of drugs are administered. Most of these medications are high-alert medications, which can cause significant harm to the patient due to its inadvertent use. Errors could be caused due to unfamiliarity with safe dosage ranges, confusion between similar looking drugs, mislabeling of drugs, equipment misuse, or malfunction and communication errors. We report a case of inadvertent infusion of a large dose of magnesium sulphate in a pregnant woman.

  10. Interdependence between body surface area and ultraviolet B dose in vitamin D production

    DEFF Research Database (Denmark)

    Bogh, M K B; Schmedes, Anne; Philipsen, P A

    2011-01-01

    Ultraviolet (UV) B radiation increases serum vitamin D level expressed as 25-hydroxyvitamin-D(3) [25(OH)D], but the relationship to body surface area and UVB dose needs investigation.......Ultraviolet (UV) B radiation increases serum vitamin D level expressed as 25-hydroxyvitamin-D(3) [25(OH)D], but the relationship to body surface area and UVB dose needs investigation....

  11. Boron Diffused Thermoluminescent Surface Layer in LiF TLDs for Skin Dose Assessments

    DEFF Research Database (Denmark)

    Christensen, Poul; Majborn, Benny

    1980-01-01

    A new high-temperature glow peak produced in a thin surface layer of LiF TLDs by diffusion of boron into the LiF material has been studied for skin dose assessments in personnel dosimetry.......A new high-temperature glow peak produced in a thin surface layer of LiF TLDs by diffusion of boron into the LiF material has been studied for skin dose assessments in personnel dosimetry....

  12. A magnetic particle micro-trap for large trapping surfaces

    KAUST Repository

    Gooneratne, Chinthaka P.

    2012-01-08

    Manipulation of micron-size magnetic particles of the superparamagnetic type contributes significantly in many applications like controlling the antibody/antigen binding process in immunoassays. Specifically, more target biomolecules can be attached/tagged and analyzed since the three dimensional structure of the magnetic particles increases the surface to volume ratio. Additionally, such biomolecular-tagged magnetic particles can be easily manipulated by an external magnetic field due to their superparamagnetic behavior. Therefore, magnetic particle- based immunoassays are extensively applied in micro-flow cytometry. The design of a square-loop micro-trap as a magnetic particle manipulator as well as numerical and experimental analysis is presented. Experimental results showed that the micro-trap could successfully trap and concentrate magnetic particles from a large to a small area with a high spatial range.

  13. Survey of doses and frequency of X-ray examinations on children at the intensive care unit of a large reference pediatric hospital

    International Nuclear Information System (INIS)

    Pedrosa de Azevedo, Ana Cecilia; Osibote, Adelaja Otolorin; Bastos Boechat, Marcia Cristina

    2006-01-01

    Objective: This work aims to evaluate the entrance surface dose (ESD), the body organ dose (BOD) and the effective dose (E) resulting from pediatric radiological procedures with the use of portable X-ray equipments. Materials and methods: The software DoseCal was used to evaluate the doses imparted to patients. The children were classified according to their weight and age groups, and the study included three sectors of the intensive care unit of a large reference pediatric hospital in Rio de Janeiro. Results: A total of 518 radiographs have been performed (424 for chest and 94 for abdomen). The statistical data were compared with previously published results. The BOD is presented for the most exposed organs. Conclusion: The mean value of ESD and E varied widely among neonates. The highest number of radiographs per infant peaked 33 for chest examination in the age group 0-1 year

  14. Threshold dose for peripheral neuropathy following intraoperative radiotherapy (IORT) in a large animal model

    International Nuclear Information System (INIS)

    Kinsella, T.J.; DeLuca, A.M.; Barnes, M.; Anderson, W.; Terrill, R.; Sindelar, W.F.

    1991-01-01

    Radiation injury to peripheral nerve is a dose-limiting toxicity in the clinical application of intraoperative radiotherapy, particularly for pelvic and retroperitoneal tumors. Intraoperative radiotherapy-related peripheral neuropathy in humans receiving doses of 20-25 Gy is manifested as a mixed motor-sensory deficit beginning 6-9 months following treatment. In a previous experimental study of intraoperative radiotherapy-related neuropathy of the lumbro-sacral plexus, an approximate inverse linear relationship was reported between the intraoperative dose (20-75 Gy range) and the time to onset of hind limb paresis (1-12 mos following intraoperative radiotherapy). The principal histological lesion in irradiated nerve was loss of large nerve fibers and perineural fibrosis without significant vascular injury. Similar histological changes in irradiated nerves were found in humans. To assess peripheral nerve injury to lower doses of intraoperative radiotherapy in this same large animal model, groups of four adult American Foxhounds received doses of 10, 15, or 20 Gy to the right lumbro-sacral plexus and sciatic nerve using 9 MeV electrons. The left lumbro-sacral plexus and sciatic nerve were excluded from the intraoperative field to allow each animal to serve as its own control. Following treatment, a complete neurological exam, electromyogram, and nerve conduction studies were performed monthly for 1 year. Monthly neurological exams were performed in years 2 and 3 whereas electromyogram and nerve conduction studies were performed every 3 months during this follow-up period. With follow-up of greater than or equal to 42 months, no dog receiving 10 or 15 Gy IORT shows any clinical or laboratory evidence of peripheral nerve injury. However, all four dogs receiving 20 Gy developed right hind limb paresis at 8, 9, 9, and 12 mos following intraoperative radiotherapy

  15. Detection for flatness of large surface based on structured light

    Science.gov (United States)

    He, Wenyan; Cao, Xuedong; Long, Kuang; Peng, Zhang

    2016-09-01

    In order to get flatness of a large plane, this paper set up a measurement system, composed by Line Structured Light, imaging system, CCD, etc. Line Structured Light transmits parallel fringes at a proper angle onto the plane which is measured; the imaging system and CCD locate above the plane to catch the fringes. When the plane is perfect, CCD will catch straight fringes; however, the real plane is not perfect; according to the theory of projection, the fringes caught by CCD will be distorted by convex and concave. Extract the center of line fringes to obtain the distortion of the fringe, according to the functional relationship between the distortion of fringes and the height which is measured, then we will get flatness of the entire surface. Data from experiment approached the analysis of theory. In the simulation, the vertical resolution is 0.0075 mm per pixel when measuring a plane of 400mm×400mm, choosing the size of CCD 4096×4096, at the angle 85°. Helped by sub-pixel, the precision will get the level of submicron. There are two obvious advantages: method of surface sampling can increase the efficiency for auto-repairing of machines; considering the center of fringe is required mainly in this system, as a consequence, there is no serious demand for back light.

  16. The clinical meaning of radiodermatitis considering the surface dose of supervoltage electron beam

    International Nuclear Information System (INIS)

    Hiraki, Tatsunosuke; Rikimaru, Shigeho; Kakishita, Masao; Kuranishi, Makoto.

    1975-01-01

    In our experience using supervoltage betatron electron beam, the skin surface dose of the electron decreased when the energy became either greater of less than 18 MeV. When we considered 18 MeV to be a 100% dose, the dose with 4 MeV, which was the least amount, corresponded to 81% of the dose. The skin surface dose of 10 MeV betatron electrons or more became greater than the 90% standard tumor dose. An external irradiation of more than 10 MeV should not be applied to neoplasms of which the curative ratio is less than 1.0. Therefore another methods such as intraoperative irradiation, should be used. The surface skin dose about 4-6 MeV betatron postoperative irradiation, particularly after resection of breast cancer, was less than the skin dose with 10 MeV. Close care should be taken to prevent hot lesions which are caused by duplication of irradiation fields. It should be kept in mind that the late effects of hot lesions caused by electron beam irradiation with an energy of 10 MeV or more are serious. (Kashu, E.)

  17. Dose Prediction for surface nuclear explosions: case studies for Semipalatinsk and Lop Nur tests

    International Nuclear Information System (INIS)

    Takada, Jun

    2008-01-01

    Dose prediction method RAPS after surface nuclear explosion has been developed by using the empirical dose function of USA nuclear test. This method which provides us external total dose, dose rate at any distant, at any time for any yield of nuclear explosion, is useful for radiation protection in case of nuclear events such as terrorism and nuclear war. The validity of RAPS has been confirmed by application to historical surface nuclear test explosions. The first test case study which was done for the first test explosion of the former USSR at the Semipalatinsk Nuclear Test Site on August 29th 1949, shows a good agreement with luminescence dosimetry on a brick. This dose prediction method was applied nuclear tests in Lop Nur. The results indicate dangerous nuclear radiation influences including fatal risk in the wide Uygur area. (author)

  18. Modified surface testing method for large convex aspheric surfaces based on diffraction optics.

    Science.gov (United States)

    Zhang, Haidong; Wang, Xiaokun; Xue, Donglin; Zhang, Xuejun

    2017-12-01

    Large convex aspheric optical elements have been widely applied in advanced optical systems, which have presented a challenging metrology problem. Conventional testing methods cannot satisfy the demand gradually with the change of definition of "large." A modified method is proposed in this paper, which utilizes a relatively small computer-generated hologram and an illumination lens with certain feasibility to measure the large convex aspherics. Two example systems are designed to demonstrate the applicability, and also, the sensitivity of this configuration is analyzed, which proves the accuracy of the configuration can be better than 6 nm with careful alignment and calibration of the illumination lens in advance. Design examples and analysis show that this configuration is applicable to measure the large convex aspheric surfaces.

  19. Differences in Radiation Dose Response between Small and Large Intestinal Crypts.

    Science.gov (United States)

    Otsuka, Kensuke; Suzuki, Keiji

    2016-09-01

    The protection of intestinal epithelial cells from the lethal effects induced by high-dose radiation is an important issue in radiotherapy and in the treatment of acute radiation syndrome. However, the effects of middle- and low-dose radiation on intestinal epithelial cells remain unclear. Because the accumulation of DNA damage in intestinal stem cells may be crucial for the development of cancer-initiating cells, it is important to understand the kinetics of DNA repair and tissue response (which are involved in the elimination of damaged cells and tissue injury repair) to middle- to low-dose irradiation. In this study, mice were X-ray irradiated with 0.1, 1 or 4 Gy, after which the small intestine (duodenum and ileum) and colon were harvested from the animals. DNA damage repair and the elimination of damaged cells were quantified by measuring the number of foci of 53BP1, a surrogate marker for DNA double-strand breaks. Tissue-proliferative response was evaluated by determining the number of Ki-67(+) and mitotic cells. Intra-crypt response differed considerably between the small intestine and the colon. In the small intestine, 53BP1 foci were detected immediately after irradiation, but rapidly disappeared thereafter, especially noticeable in Lgr5(+) stem cells. Cellular growth was temporally arrested; however, cell numbers and mitotic cell numbers in the crypt did not change. The kinetics of DNA damage repair in Lgr5(+) stem cells were similar to those in the small intestines, while the colon was more susceptible to radiation-induced damage. Preferential cell loss in the lower crypt was clearly observed in the colon; and after low-dose X-ray irradiation, only the colon exhibited considerably reduced cell numbers and dramatic induction of mitosis. These results suggest that differences in radiation dose response between the small and the large intestine may depend on the growth activity of stem cells after DNA repair.

  20. Analysis of surface absorbed dose in X-ray grating interferometry

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zhili, E-mail: wangnsrl@ustc.edu.cn [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230026 (China); Wu, Zhao; Gao, Kun; Wang, Dajiang; Chen, Heng; Wang, Shenghao [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230026 (China); Wu, Ziyu, E-mail: wuzy@ustc.edu.cn [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230026 (China); Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)

    2014-10-15

    Highlights: • Theoretical framework for dose estimation in X-ray grating interferometry. • Potential dose reduction of X-ray grating interferometry compared to conventional radiography. • Guidelines for optimization of X-ray grating interferometry for dose-sensitive applications. • Measure to compare various existing X-ray phase contrast imaging techniques. - Abstract: X-ray phase contrast imaging using grating interferometry has shown increased contrast over conventional absorption imaging, and therefore the great potential of dose reduction. The extent of the dose reduction depends on the geometry of grating interferometry, the photon energy, the properties of the sample under investigation and the utilized detector. These factors also determine the capability of grating interferometry to distinguish between different tissues with a specified statistical certainty in a single raw image. In this contribution, the required photon number for imaging and the resulting surface absorbed dose are determined in X-ray grating interferometry, using a two-component imaging object model. The presented results confirm that compared to conventional radiography, phase contrast imaging using grating interferometry indeed has the potential of dose reduction. And the extent of dose reduction is strongly dependent on the imaging conditions. Those results provide a theoretical framework for dose estimation under given imaging conditions before experimental trials, and general guidelines for optimization of grating interferometry for those dose-sensitive applications.

  1. Analysis of surface absorbed dose in X-ray grating interferometry

    International Nuclear Information System (INIS)

    Wang, Zhili; Wu, Zhao; Gao, Kun; Wang, Dajiang; Chen, Heng; Wang, Shenghao; Wu, Ziyu

    2014-01-01

    Highlights: • Theoretical framework for dose estimation in X-ray grating interferometry. • Potential dose reduction of X-ray grating interferometry compared to conventional radiography. • Guidelines for optimization of X-ray grating interferometry for dose-sensitive applications. • Measure to compare various existing X-ray phase contrast imaging techniques. - Abstract: X-ray phase contrast imaging using grating interferometry has shown increased contrast over conventional absorption imaging, and therefore the great potential of dose reduction. The extent of the dose reduction depends on the geometry of grating interferometry, the photon energy, the properties of the sample under investigation and the utilized detector. These factors also determine the capability of grating interferometry to distinguish between different tissues with a specified statistical certainty in a single raw image. In this contribution, the required photon number for imaging and the resulting surface absorbed dose are determined in X-ray grating interferometry, using a two-component imaging object model. The presented results confirm that compared to conventional radiography, phase contrast imaging using grating interferometry indeed has the potential of dose reduction. And the extent of dose reduction is strongly dependent on the imaging conditions. Those results provide a theoretical framework for dose estimation under given imaging conditions before experimental trials, and general guidelines for optimization of grating interferometry for those dose-sensitive applications

  2. Are Titan's radial Labyrinth terrains surface expressions of large laccoliths?

    Science.gov (United States)

    Schurmeier, L.; Dombard, A. J.; Malaska, M.; Radebaugh, J.

    2017-12-01

    The Labyrinth terrain unit may be the one of the best examples of the surface expression of Titan's complicated history. They are characterized as highly eroded, dissected, and elevated plateaus and remnant ridges, with an assumed composition that is likely organic-rich based on radar emissivity. How these features accumulated organic-rich sediments and formed topographic highs by either locally uplifting or surviving pervasive regional deflation or erosion is an important question for understanding the history of Titan. There are several subsets of Labyrinth terrains, presumably with differing evolutionary histories and formation processes. We aim to explain the formation of a subset of Labyrinth terrain units informally referred to as "radial Labyrinth terrains." They are elevated and appear dome-like, circular in planform, have a strong radial dissection pattern, are bordered by Undifferentiated Plains units, and are found in the mid-latitudes. Based on their shape, clustering, and dimensions, we suggest that they may be the surface expression of large subsurface laccoliths. A recent study by Manga and Michaut (Icarus, 2017) explained Europa's lenticulae (pits, domes, spots) with the formation of saucer-shaped sills that form laccoliths around the brittle-ductile transition depth within the ice shell (1-5 km). Here, we apply the same scaling relationships and find that the larger size of radial labyrinth terrains with Titan's higher gravity implies deeper intrusion depths of around 20-40 km. This intrusion depth matches the expected brittle-ductile transition on Titan based on our finite element simulations and yield strength envelope analyses. We hypothesize that Titan's radial labyrinth terrains formed as cryovolcanic (water) intrusions that rose to the brittle-ductile transition within the ice shell where they spread horizontally, and uplifted the overlying ice. The organic-rich sedimentary cover also uplifted, becoming more susceptible to pluvial and fluvial

  3. MEGARA Optics: Sub-aperture Stitching Interferometry for Large Surfaces

    Science.gov (United States)

    Aguirre-Aguirre, Daniel; Carrasco, Esperanza; Izazaga-Pérez, Rafael; Páez, Gonzalo; Granados-Agustín, Fermín; Percino-Zacarías, Elizabeth; Gil de Paz, Armando; Gallego, Jesús; Iglesias-Páramo, Jorge; Villalobos-Mendoza, Brenda

    2018-04-01

    In this work, we present a detailed analysis of sub-aperture interferogram stitching software to test circular and elliptical clear apertures with diameters and long axes up to 272 and 180 mm, respectively, from the Multi-Espectrógrafo en GTC de Alta Resolución para Astronomía (MEGARA). MEGARA is a new spectrograph for the Gran Telescopio Canarias (GTC). It offers a resolution between 6000 and 20000 via the use of volume phase holographic gratings. It has an integral field unit and a set of robots for multi-object spectroscopy at the telescope focal plane. The output end of the fibers forms the spectrograph pseudo-slit. The fixed geometry of the collimator and camera configuration requires prisms in addition to the flat windows of the volume phase holographic gratings. There are 73 optical elements of large aperture and high precision manufactured in Mexico at the Instituto Nacional de Astrofísica, Óptica y Electrónica (INAOE) and the Centro de Investigaciones en Óptica (CIO). The principle of stitching interferometry is to divide the surface being tested into overlapping small sections, which allows an easier analysis (Kim & Wyant 1981). This capability is ideal for non-contact tests for unique and large optics as required by astronomical instruments. We show that the results obtained with our sub-aperture stitching algorithm were consistent with other methods that analyze the entire aperture. We used this method to analyze the 24 MEGARA prisms that could not be tested otherwise. The instrument has been successfully commissioned at GTC in all the spectral configurations. The fulfillment of the irregularity specifications was one of the necessary conditions to comply with the spectral requirements.

  4. Surface dose measurement with Gafchromic EBT3 film for intensity modulated radiotherapy technique

    Science.gov (United States)

    Akbas, Ugur; Kesen, Nazmiye Donmez; Koksal, Canan; Okutan, Murat; Demir, Bayram; Becerir, Hatice Bilge

    2017-09-01

    Accurate dose measurement in the buildup region is extremely difficult. Studies have reported that treatment planning systems (TPS) cannot calculate surface dose accurately. The aim of the study was to compare the film measurements and TPS calculations for surface dose in head and neck cancer treatment using intensity modulated radiation therapy (IMRT). IMRT plans were generated for 5 head and neck cancer patients by using Varian Eclipse TPS. Quality assurance (QA) plans of these IMRT plans were created on rando phantoms for surface dose measurements. EBT3 films were cut in size of 2.5 x 2.5 cm2 and placed on the left side, right side and the center of larynx and then the films were irradiated with 6 MV photon beams. The measured doses were compared with TPS. The results of TPS calculations were found to be lower compared to the EBT3 film measurements at all selected points. The lack of surface dose calculation in TPS should be considered while evaluating the radiotherapy plans.

  5. Surface dose in the treatment of breast cancer with helical tomotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Zibold, Felix; Sterzing, Florian; Sroka-Perez, Gabriele; Schubert, Kai; Wagenknecht, Katja; Major, Gerald; Debus, Juergen; Herfarth, Klaus [Dept. of Radiation Oncology, Univ. of Heidelberg (Germany)

    2009-09-15

    Purpose: investigation of the effects of breathing motion- and misregistration-induced errors on the superficial dose in the treatment of breast cancer using helical tomotherapy (HT). Material and methods: surface dose measurements were performed with thermoluminescence dosimetry (TLD). Two treatment plans with different planning target volume (PTV) definitions of the left breast were used: PTV{sub skin} had its ventral border exactly on skin level, while PTV{sub air} included also a 10-mm extension ventral to the PTV{sub skin}. With a thoracic static phantom, misregistration errors in an HT were simulated. A dynamic phantom was used to simulate a breathing patient during HT. Surface doses of breast cancer patients were measured both for an HT (179 points) and a conventional three-dimensional conformal treatment (70 points). Results: in the static phantom misregistration setup, dose deviations of -31.9% for PTV{sub skin} to +35.4% for PTV{sub air} could be observed. The dynamic phantom measurements resulted in surface dose deviations from those in a static position between 0.8% and 3.8% without a significant difference for the PTV definitions. The measured surface doses on patients averaged (mean {+-} standard deviation) 1.65 {+-} 0.13 Gy for the HT and 1.42 {+-} 0.11 Gy for the three-dimensional conformal treatment. Conclusion: HT enables a homogeneous and reproducible surface dose with small dose deviations in the treatment of breast cancer. HT is a feasible method to treat breast cancer under free shallow breathing of the patient using a treatment plan with a ventral PTV border on the skin level. (orig.)

  6. Effect of Increasing Doses of γ-Radiation on Bone Marrow Stromal Cells Grown on Smooth and Rough Titanium Surfaces

    Directory of Open Access Journals (Sweden)

    Bo Huang

    2015-01-01

    Full Text Available Radiation therapy for oral and maxillofacial tumors could damage bone marrow stromal cells (BMSCs in jaw, which caused dental implant failure. However, how radiation affects BMSCs on SLA (sandblasted with large-grits, acid-etched surfaces is still unknown. The aim of this study was to investigate effect of different dose of γ-radiation on BMSCs on SLA and PT (polished titanium surfaces. Rat BMSCs were radiated with 2, 4, and 8 Gy γ-radiation and then seeded on both surfaces. Cell adhesion, spreading, and proliferation were tested. The osteogenesis and the adipogenesis ability were examined by Alizarin-Red and Oil-Red staining, respectively. Real-time PCR was performed to detect osteogenic (osteocalcin, OCN; runt-related transcription factor 2, Runx2 and adipogenic (peroxisome proliferator-activated receptor gamma, PPARγ gene expression at days 7 and 14 postirradiation. Results showed that γ-radiation reduced cell proliferation, adhesion, spreading, and osteogenic differentiation. 2 Gy radiation promoted adipogenic differentiation, but it was significantly decreased when dosage reached 4 Gy. In conclusion, results suggest that γ-radiation influenced BMSCs behaviors in a dosage-dependent manner except adipogenic differentiation, low dose promoted it, and high dose inhibited it. This effect was influenced by surface characteristics, which may explain the different failure rate of various implants in patients after radiation.

  7. Comparison of patient doses in interventional radiology procedures performed in two large hospitals in Greece

    International Nuclear Information System (INIS)

    Papageorgiou, E.; Tsapaki, V.; Tsalafoutas, I. A.; Maurikou, E.; Kottou, S.; Orfanos, A.; Karidas, G.; Fidanis, T.; Zafiriadou, E.; Neofotistou, V.

    2007-01-01

    Purpose of the study was to determine patient doses in the most common interventional radiology (IR) procedures performed in two large Greek hospitals. A total of 164 patients who underwent 4 types of IR procedures were studied. Fluoroscopy time, total exposure time, number of frames, number of runs, radiation field size, and cumulative dose-area product (DAP) were recorded. The median DAP values for carotid arteriography and lower limb arteriography were 66 and 123 Gy cm 2 for hospital 'A' and 21 and 49 Gy cm 2 for hospital 'B'. For the cerebral arteriographies performed in hospital 'A', the median DAP was 116 Gy cm 2 while for the hepatic embolizations performed in hospital 'B', it was 104 Gy cm 2 . The DAP values observed in hospital 'A' for carotid arteriography and lower limb arteriography were almost three times than those of hospital 'B'. From the data analysis, it is evident that dose optimization in hospital 'A' should be pursued through revision of the techniques used. (authors)

  8. Variation of surface dose in CT; Variacion de la dosis superficial en Tomografia Computarizada

    Energy Technology Data Exchange (ETDEWEB)

    Aviles Lucas, P.; Castellano, I. A.; Dance, D. R.; Vano Carruana, E.; Prieto Martin, C.

    2003-07-01

    An experimental study has been made of the variations of the air kerma-length product at the surface of a phantom exposed in a CT scanner using clinical parameters. the effect of patient size, position within the gantry plane and beam-shaping filter type was studied using three different elliptical phantoms. A dose reduction technique based on a sinusoidal tube current modulation system was also investigated. the result of the variation of the surface dose was analysed for the case of CT fluoroscopy procedures. The surface air kerma-length product was shown to be independent of phantom size (within experimental error) but decreases as the surface moves vertically away from the iso centre. The major contributor to this variation the beam-shaping filter. The possibility of underestimating the surface dose if an AAPM body phantom is used (a 36% increase for the head phantom) is an indirect result of the previous conclusion when applied to CT fluoroscopy. This highlights the importance of considering the size and position of the patient when measuring the does. Finally, when the tube current modulation system was used, the maximum surface dose reduction was 18%. (Author) 23 refs.

  9. Experimental characterization of micromilled surfaces by large range AFM

    DEFF Research Database (Denmark)

    Bariani, Paolo; Bissacco, Giuliano; Hansen, Hans Nørgaard

    2004-01-01

    of workpiece material, particularly when sub-micrometer chip thicknesses are considered and when machining hard materials. Quantification of surface topography is of fundamental importance for the evaluation of the generated surface; high resolution and wide measuring range being highly desirable...... for the evaluation of the distinctive behaviour of the ball end mill. The combination of the two demands is to date not matched by any measuring instrument. The paper describes an experimental investigation of surface topography of such micromachined surfaces. Accurate characterization of fine surface details...

  10. Radiolysis of aqueous solutions of ammonium bicarbonate over a large dose range

    International Nuclear Information System (INIS)

    Draganic, Z.D.; Draganic, I.G.; Negron-Mendoza, A.; Navarro-Gonzales, R.; Albarran-Sanchez, M.G.; Sehested, K.

    1986-12-01

    0 2 -free aqueous solutions of 0.05 mol dm -3 ammonium bicarbonate were studied after receiving various doses of 60 Co gammas (0.001-170 Mrd) or krd pulses of 10 MeV electrons. Formate, oxalate, formaldehyde and an unidentified polymer (M w 14000-16000 daltons) were found to be the main radiolytic products. A large initial yield of formate in the γ-radiolysis, G(HCOO - ) = 2.2, is due to the reaction CO 2 - + HCO 3 - ↔ HC00 - + CO 3 - . The efficiency of organic synthesis within the large dose range studied is low and is explained by efficient pathways to the reformation of bicarbonate, where the reaction CO 2 - + CO 3 - is particurlarly significant. Computer fitting of the data obtained in the γ-radiolysis and by pulsed electron beam experiments gives k(CO 2 - + HCO 3 - ) = (2 ± 0.4)x10 3 dm 3 mol -1 s -1 , k(CO 2 - + CO 3 - ) = (5 ± 1)x10 7 dm 3 mol -1 s -1 , k(NH 2 + = HCO 3 - ) 4 dm 3 mol -1 s -1 and k(NH 2 + CO 3 - ) = (1.5 ± 0.5)x10 9 dm 3 mol -1 s -1 . (author)

  11. Radiolysis of aqueous solutions of ammonium bicarbonate over a large dose range

    DEFF Research Database (Denmark)

    Draganic, Z.D.; Negrón-Mendoza, A.; Sehested, K.

    1991-01-01

    Oxygen-free aqueous solutions of 0.05 mol dm-3 ammonium and sodium bicarbonate were studied after receiving various doses of Co-60 gammas (0.01-400 kGy) or 0.5-20 Gy pulses of 10 Mev electrons. Formate and oxalate were found to be the main radiolytic products, in addition to trace amounts...... of formaldehyde and an unidentified polymer. A large initial yield of formate in the gamma-radiolysis, G(HCOO-) = 2.2, is due to the reaction COO- + HCO3- reversible HCOO- + CO3-. The efficiency of organic synthesis within the large dose range studied is low and is explained by efficient pathways leading...... to the reformation of bicarbonate, where the reaction COO- + CO3- is particularly significant. Computer fitting of the data obtained gives k(COO- + HCO3-) = (2 +/- 0.4) x 10(3) dm3 mol-1 s-1, k(COO- + CO3-) = (5 +/- 1) x 10(7) dm3 mol-1 s-1, k(NH2 + HCO3-)

  12. Radioeffects on the advanced breast cancer treated preoperatively by a single large dose irradiation method

    International Nuclear Information System (INIS)

    Mikuriya, Shuichi; Konoeda, Koichi; Mikami, Akihiko

    1981-01-01

    A single irradiation with a large electron dose was applied on 26 cases of advanced breast cancer in National Medical Center Hospital. Pertinent voltage from 6 to 20 MeV betatron electron was selected in accordance with tumor sizes. In eight patients, 30 Gy were given at once and other patients were irradiated with fractionated dose from 10 to 20 Gy, two or three times within 2 or 3 weeks (total 28 - 38 Gy). The radioresponse in primary and metastatic lesions was macroscopically, histopathologically and immunologically examined. Direct effects of preoperative irradiation of the primary lesions in 18 out of 24 cases (75%) were relatively remarkable by histopathological examinations. Remarkable cellular infiltrations into tumor nests of primary lesions were observed in 14 out of 24 cases (58%). Abscopal effects on metastatic lymph nodes were observed macroscopically in 7 of 20 cases (35%) and microscopic abscopal effects were seen in 10 of 20 cases (50%). In 6 cases among these ten cases macroscopic abscopal effects were associated with microscopic ones. In tests for cellular immunity, blastoid formation rates of lymphocytes induced by PHA in vitro, lymphocytes and absolute numbers of T-cells in peripheral blood slightly decreased after the irradiation. However, in four kinds of skin tests, enhancements of the response were confirmed. The crude survival rate for 3 years of Stage III cases revealed 83.3% and relative survival rate of these cases was 85.5%. A single large electron dose for the treatment of advanced breast cancer may inhibit the depression of immunoreaction in hosts. (J.P.N.)

  13. Surface dose of X rays to patients during extracorporeal shock wave lithotripsy

    International Nuclear Information System (INIS)

    Jiang Qingqi; Weng Zhigeng; Feng Ming; Wang Guomin.

    1990-01-01

    During extracorporeal shock wave lithotripsy (ESWL), the fluoroscopy must be made to show the location and size of the stone thus the patient has to be exposed to X rays. The surface dose to patients during ESWL was measured in an investigation on 134 cases of renal lithiasis admitted in a certain hospital of Shanghai. The results show that the average skin dose equivalent for these patients was 162 mSv and the magnitude of doses was depended upon some factors such as the size and location of the stone

  14. Dosimetric perturbations of a lead shield for surface and interstitial high-dose-rate brachytherapy

    International Nuclear Information System (INIS)

    Candela-Juan, Cristian; Granero, Domingo; Vijande, Javier; Ballester, Facundo; Perez-Calatayud, Jose; Rivard, Mark J

    2014-01-01

    In surface and interstitial high-dose-rate brachytherapy with either 60 Co, 192 Ir, or 169 Yb sources, some radiosensitive organs near the surface may be exposed to high absorbed doses. This may be reduced by covering the implants with a lead shield on the body surface, which results in dosimetric perturbations. Monte Carlo simulations in Geant4 were performed for the three radionuclides placed at a single dwell position. Four different shield thicknesses (0, 3, 6, and 10 mm) and three different source depths (0, 5, and 10 mm) in water were considered, with the lead shield placed at the phantom surface. Backscatter dose enhancement and transmission data were obtained for the lead shields. Results were corrected to account for a realistic clinical case with multiple dwell positions. The range of the high backscatter dose enhancement in water is 3 mm for 60 Co and 1 mm for both 192 Ir and 169 Yb. Transmission data for 60 Co and 192 Ir are smaller than those reported by Papagiannis et al (2008 Med. Phys. 35 4898–4906) for brachytherapy facility shielding; for 169 Yb, the difference is negligible. In conclusion, the backscatter overdose produced by the lead shield can be avoided by just adding a few millimetres of bolus. Transmission data provided in this work as a function of lead thickness can be used to estimate healthy organ equivalent dose saving. Use of a lead shield is justified. (paper)

  15. SU-F-T-424: Mitigation of Increased Surface Dose When Treating Through A Carbon Fiber Couch Top

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, E; Misgina, F [University of Kentucky, Lexington, KY (United States)

    2016-06-15

    Purpose: To study the effect of the Varian carbon fiber couch top on surface dose for patients being treated using single PA beams in the supine position and to identify simple methods for surface dose reduction. Methods: Measurements of surface dose were obtained in Solid Water phantoms using both a parallel plate ionization chamber (PTW Advanced Markus) and EBT2 Radiochromic films for both 6 and 10MV photons. All measurements were referenced to a depth considered a typical for PA Spine fields. Techniques used to reduce the surface dose included introducing an air standoff using Styrofoam sheets to suspend the phantom surface above the couch top and by adding a thin high Z scattering foil on the table surface. Surface doses were evaluated for typical field sizes, standoff heights, and various scattering materials. Comparisons were made to the surface dose obtainable when treating through a Varian Mylar covered tennis racket style couch top. Results: Dependence on typical spine field sizes was relatively minor. Dependence on air gap was much more significant. Surface doses decreased exponentially with increases in air standoff distance. Surface doses were reduced by approximately 50% for an air gap of 10cm and 40% for a 15cm air gap. Surface doses were reduced by an additional 15% by the addition of a 1mm Tin scattering foil. Conclusion: Using simple techniques, it is possible to reduce the surface dose when treating single PA fields through the Varian carbon fiber couch top. Surface doses can be reduced to levels observed when treating though transparent Mylar tops by adding about 15 cm of air gap. Further reductions are possible by adding thin scattering foils, such as Tin or Lead, on the couch surface. This is a low cost approach to reduce surface dose when using the Varian carbon fiber couch top.

  16. SU-F-T-424: Mitigation of Increased Surface Dose When Treating Through A Carbon Fiber Couch Top

    International Nuclear Information System (INIS)

    Johnson, E; Misgina, F

    2016-01-01

    Purpose: To study the effect of the Varian carbon fiber couch top on surface dose for patients being treated using single PA beams in the supine position and to identify simple methods for surface dose reduction. Methods: Measurements of surface dose were obtained in Solid Water phantoms using both a parallel plate ionization chamber (PTW Advanced Markus) and EBT2 Radiochromic films for both 6 and 10MV photons. All measurements were referenced to a depth considered a typical for PA Spine fields. Techniques used to reduce the surface dose included introducing an air standoff using Styrofoam sheets to suspend the phantom surface above the couch top and by adding a thin high Z scattering foil on the table surface. Surface doses were evaluated for typical field sizes, standoff heights, and various scattering materials. Comparisons were made to the surface dose obtainable when treating through a Varian Mylar covered tennis racket style couch top. Results: Dependence on typical spine field sizes was relatively minor. Dependence on air gap was much more significant. Surface doses decreased exponentially with increases in air standoff distance. Surface doses were reduced by approximately 50% for an air gap of 10cm and 40% for a 15cm air gap. Surface doses were reduced by an additional 15% by the addition of a 1mm Tin scattering foil. Conclusion: Using simple techniques, it is possible to reduce the surface dose when treating single PA fields through the Varian carbon fiber couch top. Surface doses can be reduced to levels observed when treating though transparent Mylar tops by adding about 15 cm of air gap. Further reductions are possible by adding thin scattering foils, such as Tin or Lead, on the couch surface. This is a low cost approach to reduce surface dose when using the Varian carbon fiber couch top.

  17. Monte Carlo characterization of skin doses in 6 MV transverse field MRI-linac systems: effect of field size, surface orientation, magnetic field strength, and exit bolus.

    Science.gov (United States)

    Oborn, B M; Metcalfe, P E; Butson, M J; Rosenfeld, A B

    2010-10-01

    The main focus of this work is to continue investigations into the Monte Carlo predicted skin doses seen in MRI-guided radiotherapy. In particular, the authors aim to characterize the 70 microm skin doses over a larger range of magnetic field strength and x-ray field size than in the current literature. The effect of surface orientation on both the entry and exit sides is also studied. Finally, the use of exit bolus is also investigated for minimizing the negative effects of the electron return effect (ERE) on the exit skin dose. High resolution GEANT4 Monte Carlo simulations of a water phantom exposed to a 6 MV x-ray beam (Varian 2100C) have been performed. Transverse magnetic fields of strengths between 0 and 3 T have been applied to a 30 x 30 x 20 cm3 phantom. This phantom is also altered to have variable entry and exit surfaces with respect to the beam central axis and they range from -75 degrees to +75 degrees. The exit bolus simulated is a 1 cm thick (water equivalent) slab located on the beam exit side. On the entry side, significant skin doses at the beam central axis are reported for large positive surface angles and strong magnetic fields. However, over the entry surface angle range of -30 degrees to -60 degrees, the entry skin dose is comparable to or less than the zero magnetic field skin dose, regardless of magnetic field strength and field size. On the exit side, moderate to high central axis skin dose increases are expected except at large positive surface angles. For exit bolus of 1 cm thickness, the central axis exit skin dose becomes an almost consistent value regardless of magnetic field strength or exit surface angle. This is due to the almost complete absorption of the ERE electrons by the bolus. There is an ideal entry angle range of -30 degrees to -60 degrees where entry skin dose is comparable to or less than the zero magnetic field skin dose. Other than this, the entry skin dose increases are significant, especially at higher magnetic

  18. Spiraling contaminant electrons increase doses to surfaces outside the photon beam of an MRI-linac with a perpendicular magnetic field.

    Science.gov (United States)

    Hackett, Sara L; van Asselen, Bram; Wolthaus, Jochem W H; Bluemink, J J; Ishakoglu, Kübra; Kok, Jan G M; Lagendijk, Jan J W; Raaymakers, Bas W

    2018-03-29

    The transverse magnetic field of an MRI-linac sweeps contaminant electrons away from the radiation beam. Films oriented perpendicular to the magnetic field and 5cm from the radiation beam edge show a projection of the divergent beam, indicating that contaminant electrons spiral along magnetic field lines and deposit dose on surfaces outside the primary beam perpendicular to the magnetic field. These spiraling contaminant electrons (SCE) could increase skin doses to protruding regions of the patient along the cranio-caudal axis. This study investigated doses from SCE for an MRI-linac comprising a 7MV linac and a 1.5T MRI scanner. Surface doses to films perpendicular to the magnetic field and 5cm from the radiation beam edge showed increased dose within the projection of the primary beam, whereas films parallel to the magnetic field and 5cm from the beam edge showed no region of increased dose. However, the dose from contaminant electrons is absorbed within a few millimeters. For large fields, the SCE dose is within the same order of magnitude as doses from scattered and leakage photons. Doses for both SCE and scattered photons decrease rapidly with decreasing beam size and increasing distance from the beam edge. © 2018 Institute of Physics and Engineering in Medicine.

  19. Calculated dose factors for the radiosensitive tissues in bone irradiated by surface-deposited radionuclides

    International Nuclear Information System (INIS)

    Spiers, F.W.; Whitwell, J.R.; Beddoe, A.H.

    1978-01-01

    The method of calculating dose factors for the haemopoietic marrow and endosteal tissues in human trabecular bone, used by Whitwell and Spiers for volume-seeking radionuclides, has been developed for the case of radionuclides which are deposited as very thin layers on bone surfaces. The Monte Carlo method is again used, but modifications to the computer program are made to allow for a surface rather than a volume source of particle emission. The principal change is the introduction of a surface-orientation factor which is shown to have a value of approximately 2, varying slightly with bone structure. Results are given for β-emitting radionuclides ranging from 171 Tm(anti Esub(β) = 0.025 MeV) to 90 Y(anti Esub(β) = 0.93 MeV), and also for the α-emitter 239 Pu. It is shown that where the particle ranges are short compared with the dimensions of the bone structures the dose factors for the surface seekers are much greater than those for the volume seekers. For long range particles the dose factors for surface- and volume-seeking radionuclides converge. Comparisons are given relating the dose factors calculated in this paper on the basis of measured bone structures to those of other workers based on single plane geometry. (author)

  20. SU-F-T-93: Breast Surface Dose Enhancement Using a Clinical Prone Breast Board

    Energy Technology Data Exchange (ETDEWEB)

    Guerra, M; Jozsef, G [New York University Langone Medical Center, New York, NY (United States)

    2016-06-15

    Purpose: The use of specialized patient set-up devices in radiotherapy, such as prone breast boards, may have unwanted dosimetric effects. The goal of this study was to evaluate the effect of a clinically used prone breast board on skin dose due to buildup. Methods: GafChromic film (EBT3) was used for dose measurements on the surface of a solid water phantom shaped to mimic the curvature of the breast. We investigated two setup scenarios: the medial field border placed at the medial edge of the board and 1 cm contralaterally from that edge. A strip of film was taped to the medial surface of the phantom. Gantry angles varied from 10 to 30 degrees below the lateral gantry position, representing anterior oblique fields. The measurements were performed with and without the presence of the board; the ratio of their corresponding doses (dose enhancement) was evaluated. Results: For the cases where the field edge is at the edge of the board, the dose enhancement is negligible for all the tested angles. When the field edge is 1 cm inside the board, the maximum surface dose enhancement varies depending on the gantry angle between 2.2 for 30 degrees and 3.2 for 20 degrees. The length on the film at which the presence of the board is detectable (i.e. where there is dose enhancement) is longer for the shallower angles. Conclusion: Even the low-density, thin carbon fiber board with a thin soft foam pad on the top can produce significant dose enhancement on the skin in prone breast treatment due to loss of buildup. However, it happens only when the patient mid-sternum is over the board, i.e. the medial edge of the field traverses through the board and pad. Even then, the effect occurs only at the field edge, i.e. the penumbral region.

  1. Oxygen dosing the surface of SrTiO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Dudy, L.; Scheiderer, P.; Schuetz, P.; Gabel, J.; Buchwald, M.; Sing, M.; Claessen, R. [Physikalisches Institut, Universitaet Wuerzburg (Germany); Denlinger, J.D. [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA, 94270 (United States); Schlueter, C.; Lee, T.L. [Diamond Light Source Ltd., Didcot, Oxfordshire (United Kingdom)

    2015-07-01

    The highly mobile two-dimensional electron system (2DES) on the surface of the insulating SrTiO{sub 3}(STO) offers exciting perspectives for advanced material design. This 2DES resides in a depletion layer caused by oxygen deficiency of the surface. With photoemission spectroscopy, we monitor the appearance of quasi-particle weight (QP) at the Fermi energy and oxygen vacancy induced states in the band gap (IG). Both, QP and IG weight, increase and decrease respectively upon exposure to extreme ultraviolet (XUV) light and in-situ oxygen dosing. By a proper adjustment of oxygen dosing, any intermediate state can be stabilized providing full control over the charge carrier density. From a comparison of the charge carrier concentrations obtained from an analysis of core-level spectra and the Fermi-surface volume, we conclude on a spatially inhomogeneous surface electronic structure with at least two different phases.

  2. Surface membrane based bladder registration for evaluation of accumulated dose during brachytherapy in cervical cancer

    DEFF Research Database (Denmark)

    Noe, Karsten Østergaard; Tanderup, Kari; Sørensen, Thomas Sangild

    2011-01-01

    of the fixed surface. Optional landmark based matches can be included in the suggested iterative solver. The technique is demonstrated for bladder registration in brachytherapy treatment evaluation of cervical cancer. It holds promise to better estimate the accumulated but unintentional dose delivered...

  3. Printable organometallic perovskite enables large-area, low-dose X-ray imaging.

    Science.gov (United States)

    Kim, Yong Churl; Kim, Kwang Hee; Son, Dae-Yong; Jeong, Dong-Nyuk; Seo, Ja-Young; Choi, Yeong Suk; Han, In Taek; Lee, Sang Yoon; Park, Nam-Gyu

    2017-10-04

    Medical X-ray imaging procedures require digital flat detectors operating at low doses to reduce radiation health risks. Solution-processed organic-inorganic hybrid perovskites have characteristics that make them good candidates for the photoconductive layer of such sensitive detectors. However, such detectors have not yet been built on thin-film transistor arrays because it has been difficult to prepare thick perovskite films (more than a few hundred micrometres) over large areas (a detector is typically 50 centimetres by 50 centimetres). We report here an all-solution-based (in contrast to conventional vacuum processing) synthetic route to producing printable polycrystalline perovskites with sharply faceted large grains having morphologies and optoelectronic properties comparable to those of single crystals. High sensitivities of up to 11 microcoulombs per air KERMA of milligray per square centimetre (μC mGy air -1 cm -2 ) are achieved under irradiation with a 100-kilovolt bremsstrahlung source, which are at least one order of magnitude higher than the sensitivities achieved with currently used amorphous selenium or thallium-doped cesium iodide detectors. We demonstrate X-ray imaging in a conventional thin-film transistor substrate by embedding an 830-micrometre-thick perovskite film and an additional two interlayers of polymer/perovskite composites to provide conformal interfaces between perovskite films and electrodes that control dark currents and temporal charge carrier transportation. Such an all-solution-based perovskite detector could enable low-dose X-ray imaging, and could also be used in photoconductive devices for radiation imaging, sensing and energy harvesting.

  4. Printable organometallic perovskite enables large-area, low-dose X-ray imaging

    Science.gov (United States)

    Kim, Yong Churl; Kim, Kwang Hee; Son, Dae-Yong; Jeong, Dong-Nyuk; Seo, Ja-Young; Choi, Yeong Suk; Han, In Taek; Lee, Sang Yoon; Park, Nam-Gyu

    2017-10-01

    Medical X-ray imaging procedures require digital flat detectors operating at low doses to reduce radiation health risks. Solution-processed organic–inorganic hybrid perovskites have characteristics that make them good candidates for the photoconductive layer of such sensitive detectors. However, such detectors have not yet been built on thin-film transistor arrays because it has been difficult to prepare thick perovskite films (more than a few hundred micrometres) over large areas (a detector is typically 50 centimetres by 50 centimetres). We report here an all-solution-based (in contrast to conventional vacuum processing) synthetic route to producing printable polycrystalline perovskites with sharply faceted large grains having morphologies and optoelectronic properties comparable to those of single crystals. High sensitivities of up to 11 microcoulombs per air KERMA of milligray per square centimetre (μC mGyair‑1 cm‑2) are achieved under irradiation with a 100-kilovolt bremsstrahlung source, which are at least one order of magnitude higher than the sensitivities achieved with currently used amorphous selenium or thallium-doped cesium iodide detectors. We demonstrate X-ray imaging in a conventional thin-film transistor substrate by embedding an 830-micrometre-thick perovskite film and an additional two interlayers of polymer/perovskite composites to provide conformal interfaces between perovskite films and electrodes that control dark currents and temporal charge carrier transportation. Such an all-solution-based perovskite detector could enable low-dose X-ray imaging, and could also be used in photoconductive devices for radiation imaging, sensing and energy harvesting.

  5. Impact of thermoplastic mask on X-ray surface dose calculated with Monte Carlo code

    International Nuclear Information System (INIS)

    Zhao Yanqun; Li Jie; Wu Liping; Wang Pei; Lang Jinyi; Wu Dake; Xiao Mingyong

    2010-01-01

    Objective: To calculate the effects of thermoplastic mask on X-ray surface dose. Methods: The BEAMnrc Monte Carlo Code system, designed especially for computer simulation of radioactive sources, was performed to evaluate the effects of thermoplastic mask on X-ray surface dose.Thermoplastic mask came from our center with a material density of 1.12 g/cm 2 . The masks without holes, with holes size of 0.1 cm x 0.1 cm, and with holes size of 0. 1 cm x 0.2 cm, and masks with different depth (0.12 cm and 0.24 cm) were evaluated separately. For those with holes, the material width between adjacent holes was 0.1 cm. Virtual masks with a material density of 1.38 g/cm 3 without holes with two different depths were also evaluated. Results: Thermoplastic mask affected X-rays surface dose. When using a thermoplastic mask with the depth of 0.24 cm without holes, the surface dose was 74. 9% and 57.0% for those with the density of 1.38 g/cm 3 and 1.12 g/cm 3 respectively. When focusing on the masks with the density of 1.12 g/cm 3 , the surface dose was 41.2% for those with 0.12 cm depth without holes; 57.0% for those with 0. 24 cm depth without holes; 44.5% for those with 0.24 cm depth with holes size of 0.1 cm x 0.2 cm;and 54.1% for those with 0.24 cm depths with holes size of 0.1 cm x 0.1 cm.Conclusions: Using thermoplastic mask during the radiation increases patient surface dose. The severity is relative to the hole size and the depth of thermoplastic mask. The surface dose change should be considered in radiation planning to avoid severe skin reaction. (authors)

  6. X-ray tube output based calculation of patient entrance surface dose: validation of the method

    Energy Technology Data Exchange (ETDEWEB)

    Harju, O.; Toivonen, M.; Tapiovaara, M.; Parviainen, T. [Radiation and Nuclear Safety Authority, Helsinki (Finland)

    2003-06-01

    X-ray departments need methods to monitor the doses delivered to the patients in order to be able to compare their dose level to established reference levels. For this purpose, patient dose per radiograph is described in terms of the entrance surface dose (ESD) or dose-area product (DAP). The actual measurement is often made by using a DAP-meter or thermoluminescent dosimeters (TLD). The third possibility, the calculation of ESD from the examination technique factors, is likely to be a common method for x-ray departments that do not have the other methods at their disposal or for examinations where the dose may be too low to be measured by the other means (e.g. chest radiography). We have developed a program for the determination of ESD by the calculation method and analysed the accuracy that can be achieved by this indirect method. The program calculates the ESD from the current time product, x-ray tube voltage, beam filtration and focus- to-skin distance (FSD). Additionally, for calibrating the dose calculation method and thereby improving the accuracy of the calculation, the x-ray tube output should be measured for at least one x-ray tube voltage value in each x-ray unit. The aim of the present work is to point out the restrictions of the method and details of its practical application. The first experiences from the use of the method will be summarised. (orig.)

  7. A Generalized Approach to Model the Spectra and Radiation Dose Rate of Solar Particle Events on the Surface of Mars

    Science.gov (United States)

    Guo, Jingnan; Zeitlin, Cary; Wimmer-Schweingruber, Robert F.; McDole, Thoren; Kühl, Patrick; Appel, Jan C.; Matthiä, Daniel; Krauss, Johannes; Köhler, Jan

    2018-01-01

    For future human missions to Mars, it is important to study the surface radiation environment during extreme and elevated conditions. In the long term, it is mainly galactic cosmic rays (GCRs) modulated by solar activity that contribute to the radiation on the surface of Mars, but intense solar energetic particle (SEP) events may induce acute health effects. Such events may enhance the radiation level significantly and should be detected as immediately as possible to prevent severe damage to humans and equipment. However, the energetic particle environment on the Martian surface is significantly different from that in deep space due to the influence of the Martian atmosphere. Depending on the intensity and shape of the original solar particle spectra, as well as particle types, the surface spectra may induce entirely different radiation effects. In order to give immediate and accurate alerts while avoiding unnecessary ones, it is important to model and well understand the atmospheric effect on the incoming SEPs, including both protons and helium ions. In this paper, we have developed a generalized approach to quickly model the surface response of any given incoming proton/helium ion spectra and have applied it to a set of historical large solar events, thus providing insights into the possible variety of surface radiation environments that may be induced during SEP events. Based on the statistical study of more than 30 significant solar events, we have obtained an empirical model for estimating the surface dose rate directly from the intensities of a power-law SEP spectra.

  8. Multiview specular stereo reconstruction of large mirror surfaces

    KAUST Repository

    Balzer, Jonathan

    2011-06-01

    In deflectometry, the shape of mirror objects is recovered from distorted images of a calibrated scene. While remarkably high accuracies are achievable, state-of-the-art methods suffer from two distinct weaknesses: First, for mainly constructive reasons, these can only capture a few square centimeters of surface area at once. Second, reconstructions are ambiguous i.e. infinitely many surfaces lead to the same visual impression. We resolve both of these problems by introducing the first multiview specular stereo approach, which jointly evaluates a series of overlapping deflectometric images. Two publicly available benchmarks accompany this paper, enabling us to numerically demonstrate viability and practicability of our approach. © 2011 IEEE.

  9. Effectiveness of hearing conservation program at a large surface ...

    African Journals Online (AJOL)

    A study conducted to determine the effectiveness of a Hearing Conservation Programme (HcP) was conducted in a surface gold mining Company in Ghana. The procedure adopted included a retrospective review and comparison of individual Audiograms from 1999-2003. The analysis of data was based on 200 workers at ...

  10. Calculation of rectal dose surface histograms in the presence of time varying deformations

    International Nuclear Information System (INIS)

    Roeske, John C.; Spelbring, Danny R.; Vijayakumar, S.; Forman, Jeffrey D.; Chen, George T.Y.

    1996-01-01

    Purpose: Dose volume (DVH) and dose surface histograms (DSH) of the bladder and rectum are usually calculated from a single treatment planning scan. These DVHs and DSHs will eventually be correlated with complications to determine parameters for normal tissue complication probabilities (NTCP). However, from day to day, the size and shape of the rectum and bladder may vary. The purpose of this study is to compare a more accurate estimate of the time integrated DVHs and DSHs of the rectum (in the presence of daily variations in rectal shape) to initial DVHs/DSHs. Methods: 10 patients were scanned once per week during the course of fractionated radiotherapy, typically accumulating a total of six scans. The rectum and bladder were contoured on each of the studies. The model used to assess effects of rectal contour deformation is as follows: the contour on a given axial slice (see figure) is boxed within a rectangle. A line drawn parallel to the AP axis through the rectangle equally partitions the box. Starting at the intersection of the vertical line and the rectal contour, points on the contour are marked off representing the same rectal dose point, even in the presence of distortion. Corresponding numbered points are used to sample the dose matrix and create a composite DSH. The model assumes uniform stretching of the rectal contour for any given axial cut, and no twist of the structure or vertical displacement. A similar model is developed for the bladder with spherical symmetry. Results: Normalized DSHs (nDSH) for each CT scan were calculated as well as the time averaged nDSH over all scans. These were compared with the nDSH from the initial planning scan. Individual nDSHs differed by 8% surface area irradiated at the 80% dose level, to as much as 20% surface area in the 70-100% dose range. DSH variations are due to position and shape changes in the rectum during different CT scans. The spatial distribution of dose is highly variable, and depends on the field

  11. The biological effect of large single doses: a possible role for non-targeted effects in cell inactivation.

    Directory of Open Access Journals (Sweden)

    Marlon R Veldwijk

    Full Text Available BACKGROUND AND PURPOSE: Novel radiotherapy techniques increasingly use very large dose fractions. It has been argued that the biological effect of large dose fractions may differ from that of conventional fraction sizes. The purpose was to study the biological effect of large single doses. MATERIAL AND METHODS: Clonogenic cell survival of MCF7 and MDA-MB-231 cells was determined after direct X-ray irradiation, irradiation of feeder cells, or transfer of conditioned medium (CM. Cell-cycle distributions and the apoptotic sub-G1 fraction were measured by flow cytometry. Cytokines in CM were quantified by a cytokine antibody array. γH2AX foci were detected by immunofluorescence microscopy. RESULTS: The surviving fraction of MCF7 cells irradiated in vitro with 12 Gy showed an 8.5-fold decrease (95% c.i.: 4.4-16.3; P<0.0001 when the density of irradiated cells was increased from 10 to 50×10(3 cells per flask. Part of this effect was due to a dose-dependent transferrable factor as shown in CM experiments in the dose range 5-15 Gy. While no effect on apoptosis and cell cycle distribution was observed, and no differentially expressed cytokine could be identified, the transferable factor induced prolonged expression of γH2AX DNA repair foci at 1-12 h. CONCLUSIONS: A dose-dependent non-targeted effect on clonogenic cell survival was found in the dose range 5-15 Gy. The dependence of SF on cell numbers at high doses would represent a "cohort effect" in vivo. These results support the hypothesis that non-targeted effects may contribute to the efficacy of very large dose fractions in radiotherapy.

  12. Using dose-surface maps to predict radiation-induced rectal bleeding: a neural network approach

    Science.gov (United States)

    Buettner, Florian; Gulliford, Sarah L.; Webb, Steve; Partridge, Mike

    2009-09-01

    The incidence of late-toxicities after radiotherapy can be modelled based on the dose delivered to the organ under consideration. Most predictive models reduce the dose distribution to a set of dose-volume parameters and do not take the spatial distribution of the dose into account. The aim of this study was to develop a classifier predicting radiation-induced rectal bleeding using all available information on the dose to the rectal wall. The dose was projected on a two-dimensional dose-surface map (DSM) by virtual rectum-unfolding. These DSMs were used as inputs for a classification method based on locally connected neural networks. In contrast to fully connected conventional neural nets, locally connected nets take the topology of the input into account. In order to train the nets, data from 329 patients from the RT01 trial (ISRCTN 47772397) were split into ten roughly equal parts. By using nine of these parts as a training set and the remaining part as an independent test set, a ten-fold cross-validation was performed. Ensemble learning was used and 250 nets were built from randomly selected patients from the training set. Out of these 250 nets, an ensemble of expert nets was chosen. The performances of the full ensemble and of the expert ensemble were quantified by using receiver-operator-characteristic (ROC) curves. In order to quantify the predictive power of the shape, ensembles of fully connected conventional neural nets based on dose-surface histograms (DSHs) were generated and their performances were quantified. The expert ensembles performed better than or equally as well as the full ensembles. The area under the ROC curve for the DSM-based expert ensemble was 0.64. The area under the ROC curve for the DSH-based expert ensemble equalled 0.59. This difference in performance indicates that not only volumetric, but also morphological aspects of the dose distribution are correlated to rectal bleeding after radiotherapy. Thus, the shape of the dose

  13. Using dose-surface maps to predict radiation-induced rectal bleeding: a neural network approach

    Energy Technology Data Exchange (ETDEWEB)

    Buettner, Florian; Gulliford, Sarah L; Webb, Steve; Partridge, Mike [Joint Department of Physics, Institute of Cancer Research and Royal Marsden NHS Foundation Trust, Sutton, Surrey SM2 5PT (United Kingdom)], E-mail: florian.buttner@icr.ac.uk

    2009-09-07

    The incidence of late-toxicities after radiotherapy can be modelled based on the dose delivered to the organ under consideration. Most predictive models reduce the dose distribution to a set of dose-volume parameters and do not take the spatial distribution of the dose into account. The aim of this study was to develop a classifier predicting radiation-induced rectal bleeding using all available information on the dose to the rectal wall. The dose was projected on a two-dimensional dose-surface map (DSM) by virtual rectum-unfolding. These DSMs were used as inputs for a classification method based on locally connected neural networks. In contrast to fully connected conventional neural nets, locally connected nets take the topology of the input into account. In order to train the nets, data from 329 patients from the RT01 trial (ISRCTN 47772397) were split into ten roughly equal parts. By using nine of these parts as a training set and the remaining part as an independent test set, a ten-fold cross-validation was performed. Ensemble learning was used and 250 nets were built from randomly selected patients from the training set. Out of these 250 nets, an ensemble of expert nets was chosen. The performances of the full ensemble and of the expert ensemble were quantified by using receiver-operator-characteristic (ROC) curves. In order to quantify the predictive power of the shape, ensembles of fully connected conventional neural nets based on dose-surface histograms (DSHs) were generated and their performances were quantified. The expert ensembles performed better than or equally as well as the full ensembles. The area under the ROC curve for the DSM-based expert ensemble was 0.64. The area under the ROC curve for the DSH-based expert ensemble equalled 0.59. This difference in performance indicates that not only volumetric, but also morphological aspects of the dose distribution are correlated to rectal bleeding after radiotherapy. Thus, the shape of the dose

  14. Large Area Diamond Tribological Surfaces with Negligible Wear in Extreme Environments, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — In Phase I we propose to demonstrate the processing of very large area diamond sliding bearings and tribological surfaces. The bearings and surfaces will experience...

  15. Large area optical mapping of surface contact angle.

    Science.gov (United States)

    Dutra, Guilherme; Canning, John; Padden, Whayne; Martelli, Cicero; Dligatch, Svetlana

    2017-09-04

    Top-down contact angle measurements have been validated and confirmed to be as good if not more reliable than side-based measurements. A range of samples, including industrially relevant materials for roofing and printing, has been compared. Using the top-down approach, mapping in both 1-D and 2-D has been demonstrated. The method was applied to study the change in contact angle as a function of change in silver (Ag) nanoparticle size controlled by thermal evaporation. Large area mapping reveals good uniformity for commercial Aspen paper coated with black laser printer ink. A demonstration of the forensic and chemical analysis potential in 2-D is shown by uncovering the hidden CsF initials made with mineral oil on the coated Aspen paper. The method promises to revolutionize nanoscale characterization and industrial monitoring as well as chemical analyses by allowing rapid contact angle measurements over large areas or large numbers of samples in ways and times that have not been possible before.

  16. Variations of Polymer Porous Surface Structures via the Time-Sequenced Dosing of Mixed Solvents.

    Science.gov (United States)

    Wrzecionko, Erik; Minařík, Antonín; Smolka, Petr; Minařík, Martin; Humpolíček, Petr; Rejmontová, Petra; Mráček, Aleš; Minaříková, Magda; Gřundělová, Lenka

    2017-02-22

    A new approach to polystyrene surface treatment via the time-sequenced dispensing of good and poor solvent mixtures on the rotating surface of treated substrate is presented in this study. It is demonstrated that the variation of the sequencing together with other variables (e.g., temperature and solvent concentration) affects the size and depth of pores evolving on the polystyrene surface. A model of the surface pore creation, associated with the viscoelastic phase separation, surface tension, and secondary flows caused by temperature variations and the rapid evaporation of the good solvent is proposed. Experimental results of profilometric, goniometric, and optical measurements show that this approach enables the simple and quick preparation of surfaces with various numbers, diameters, and depths of individual pores, which ultimately affects not only the wetting characteristics of the surfaces but also the fate of cells cultivated there. The presented method allows the easy preparation of a large number of structured substrates for effective cell cultivation and proliferation.

  17. SSD effects on high energy x-ray surface and build up dose

    International Nuclear Information System (INIS)

    Cheung, T.; Yu, P.K.N.; Butson, M.J.; Cancer Services, Wollongong, NSW

    2004-01-01

    Full text: Dose in the build up region for high energy x-rays produced by a medical linear accelerator is affected by the x-ray source to patient surface distance (SSD). The use of isocentric treatments whereby the tumour is positions 100cm from the source means that depending of the depth of the tumour and the size of the patient, the SSD can vary from distances of 80cm to 100cm. To achieve larger field sizes, the SSD can also be extended out to 120cm at times. Results have shown that open fields are not significantly affected by SSD changes with deviations in percentage dose being less than 4% of maximum dose for SSD's from 80cm to 120cm SSD. With the introduction of beam modifying devices such as Perspex blocking trays, the effects are significant with a deviation of up to 22% measured at 6MV energy with a 6mm Perspex tray for SSD's from 80cm to 120cm. These variations are largest at the skin surface and reduce with depth. The use of a multi leaf collimator for blocking removes extra skin dose caused by the Perspex block trays with decreasing SSD. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  18. Field investigation of surface-deposited radon progeny as a possible predictor of the airborne radon progeny dose rate.

    Science.gov (United States)

    Sun, Kainan; Steck, Daniel J; Field, R William

    2009-08-01

    The quantitative relationships between radon gas concentration, the surface-deposited activities of various radon progeny, the airborne radon progeny dose rate, and various residential environmental factors were investigated through actual field measurements in 38 selected Iowa houses occupied by either smokers or nonsmokers. Airborne dose rate was calculated from unattached and attached potential alpha energy concentrations (PAECs) using two dosimetric models with different activity-size weighting factors. These models are labeled Pdose and Jdose, respectively. Surface-deposited 218Po and 214Po were found significantly correlated to radon, unattached PAEC, and both airborne dose rates (p fireplace, or usage of a ceiling fan significantly, or marginally significantly, reduced the Pdose to 0.65 (90% CI 0.42-0.996), 0.54 (90% CI 0.28-1.02), and 0.66 (90% CI 0.45-0.96), respectively. For Jdose, only the usage of a ceiling fan significantly reduced the dose rate to 0.57 (90% CI 0.39-0.85). In smoking environments, deposited 218Po was a significant negative predictor for Pdose (RR 0.68, 90% CI 0.55-0.84) after adjusting for long-term 222Rn and environmental factors. A significant decrease of 0.72 (90% CI 0.64-0.83) in the mean Pdose was noted, after adjusting for the radon and radon progeny effects and other environmental factors, for every 10 additional cigarettes smoked in the room. A significant increase of 1.71 in the mean Pdose was found for large room size relative to small room size (90% CI 1.08-2.79) after adjusting for the radon and radon progeny effects as well as other environmental factors. Fireplace usage was found to significantly increase the mean Pdose to 1.71 (90% CI 1.20-2.45) after adjusting for other factors.

  19. A control study of TACE using high-dosed and routine-dosed iodized oil as a treatment of large hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Zhou Junmin; Zhan Jincheng; Zhang Zhenming

    2005-01-01

    Objective: To investigate the side effects and curative effect in high-dosed lipiodol-transcatheter arterial chemoembolization as a treatment of large hepatocellular carcinoma. Methods: 79 patients with unresectable hepatocellular carcinoma were treated by TACE, and divided into 2 groups. In group A, 39 patients with the tumor sized 7-18cm in diameter, routine-dosed, 10-20ml lipiodol was given in TACE. 40 patients were enrolled in the high-dosed group B, who were given more than 20ml iodized oil in TACE. Results: The First to third year survival rate of group A was 66.7%, 33.3%, 0% respectively,while in group B it was 75%, 45%, 7.5% respectively. The effective rate was 71.7% in Group A and 87.5% in Group B. There was a significant difference between both groups. There was no significant difference of critical side effects and liver function damage between group A and B. Conclusion: High-dosed lipiodol chemoembolization as a treatment of unresectable hepatocellular carcinoma is superior to the routine TACE, especially when the tumor is large and the liver function reserve is good. (authors)

  20. Extrapolated surface dose measurements using a NdFeB magnetic deflector for 6 MV x-ray beams.

    Science.gov (United States)

    Damrongkijudom, N; Butson, M; Rosenfeld, A

    2007-03-01

    Extrapolated surface dose measurements have been performed using radiographic film to measure 2-Dimensional maps of skin and surface dose with and without a magnetic deflector device aimed at reducing surface dose. Experiments are also performed using an Attix parallel plate ionisation chamber for comparison to radiographic film extrapolation surface dose analysis. Extrapolated percentage surface dose assessments from radiographic film at the central axis of a 6 MV x-ray beam with magnetic deflector for field size 10 x 10 cm2, 15 x 15 cm2 and 20 x 20 cm2 are 9 +/- 3%, 13 +/- 3% and 16 +/- 3%, these compared to 14 +/- 3%, 19 +/- 3%, and 27 +/- 3% for open fields, respectively. Results from Attix chamber for the same field size are 12 +/- 1%, 15 +/- 1% and 18 +/- 1%, these compared to 16 +/- 1%, 21 +/- 1% and 27 +/- 1% for open fields, respectively. Results are also shown for profiles measured in-plane and cross-plane to the magnetic deflector and compared to open field data. Results have shown that the surface dose is reduced at all sites within the treatment field with larger reductions seen on one side of the field due to the sweeping nature of the designed magnetic field. Radiographic film extrapolation provides an advanced surface dose assessment and has matched well with Attix chamber results. Film measurement allows for easy 2 dimensional dose assessments.

  1. DS86 neutron dose. Monte Carlo analysis for depth profile of {sup 152}Eu activity in a large stone sample

    Energy Technology Data Exchange (ETDEWEB)

    Endo, Satoru; Hoshi, Masaharu; Takada, Jun [Hiroshima Univ. (Japan). Research Inst. for Radiation Biology and Medicine; Iwatani, Kazuo; Oka, Takamitsu; Shizuma, Kiyoshi; Imanaka, Tetsuji; Fujita, Shoichiro; Hasai, Hiromi

    1999-06-01

    The depth profile of {sup 152}Eu activity induced in a large granite stone pillar by Hiroshima atomic bomb neutrons was calculated by a Monte Carlo N-Particle Transport Code (MCNP). The pillar was on the Motoyasu Bridge, located at a distance of 132 m (WSW) from the hypocenter. It was a square column with a horizontal sectional size of 82.5 cm x 82.5 cm and height of 179 cm. Twenty-one cells from the north to south surface at the central height of the column were specified for the calculation and {sup 152}Eu activities for each cell were calculated. The incident neutron spectrum was assumed to be the angular fluence data of the Dosimetry System 1986 (DS86). The angular dependence of the spectrum was taken into account by dividing the whole solid angle into twenty-six directions. The calculated depth profile of specific activity did not agree with the measured profile. A discrepancy was found in the absolute values at each depth with a mean multiplication factor of 0.58 and also in the shape of the relative profile. The results indicated that a reassessment of the neutron energy spectrum in DS86 is required for correct dose estimation. (author)

  2. SU-E-T-44: Angular Dependence of Surface Dose Enhancement Measured On Several Inhomogeneities Using Radiochromic EBT3 Films

    Energy Technology Data Exchange (ETDEWEB)

    Jansen, A; Schoenfeld, A; Poppinga, D; Chofor, N; Poppe, B [University of Oldenburg, Oldenburg (Germany); Pius Hospital Oldenburg, Oldenburg (Germany)

    2014-06-01

    Purpose: The quantification of the relative surface dose enhancement in dependence on the angle of incidence and the atomic number Z of the surface material. Methods: Experiments were performed with slabs made of aluminum, titanium, copper, silver, dental gold and lead. The metal slabs with equal sizes of 1.0×8.0×8.8mm{sup 3} were embedded in an Octavius 4D phantom (PTW Freiburg, Germany). Radiochromic EBT3 films were used to measure the surface dose for angles of incidence ranging from 0° to 90°. The setup with the metals slabs at the isocenter was irradiated with acceleration voltages of 6MV and 10MV. Water reference measurements were taken under equal conditions. Results: The surface dose enhancement is highest for angles of incidence below 30° and drops significantly for higher. The surface dose enhancement produced by lead and dental gold at 6MV showed a peak of 65%. At 90°, the surface dose enhancement dropped to 15% for both materials. The surface dose enhancements for silver, copper, titanium and aluminum were 45%, 32%, 22% and 12% at 0°, respectively. At an angle of incidence of 80°, the values dropped to 22%, 18%, 12% und 6%. The values for 10MV were very similar. Lead and dental gold showed peaks of 65% und 60%. Their values dropped to 18% at an angle of 90°. The surface dose enhancements for silver, copper, titanium and aluminum were 45%, 30%, 20% and 8% at 0°. At 80° the values dropped to 30%, 20%, 12% and 5%. A dependence of the magnitude of the surface dose enhancement on the atomic number of the surface material can be seen, which is in consistence with literature. Conclusion: The results show that the surface dose enhancements near implant materials with high Z-values should be taken into consideration in radio therapy, even when the angle of incidence is flat.

  3. SU-E-T-44: Angular Dependence of Surface Dose Enhancement Measured On Several Inhomogeneities Using Radiochromic EBT3 Films

    International Nuclear Information System (INIS)

    Jansen, A; Schoenfeld, A; Poppinga, D; Chofor, N; Poppe, B

    2014-01-01

    Purpose: The quantification of the relative surface dose enhancement in dependence on the angle of incidence and the atomic number Z of the surface material. Methods: Experiments were performed with slabs made of aluminum, titanium, copper, silver, dental gold and lead. The metal slabs with equal sizes of 1.0×8.0×8.8mm 3 were embedded in an Octavius 4D phantom (PTW Freiburg, Germany). Radiochromic EBT3 films were used to measure the surface dose for angles of incidence ranging from 0° to 90°. The setup with the metals slabs at the isocenter was irradiated with acceleration voltages of 6MV and 10MV. Water reference measurements were taken under equal conditions. Results: The surface dose enhancement is highest for angles of incidence below 30° and drops significantly for higher. The surface dose enhancement produced by lead and dental gold at 6MV showed a peak of 65%. At 90°, the surface dose enhancement dropped to 15% for both materials. The surface dose enhancements for silver, copper, titanium and aluminum were 45%, 32%, 22% and 12% at 0°, respectively. At an angle of incidence of 80°, the values dropped to 22%, 18%, 12% und 6%. The values for 10MV were very similar. Lead and dental gold showed peaks of 65% und 60%. Their values dropped to 18% at an angle of 90°. The surface dose enhancements for silver, copper, titanium and aluminum were 45%, 30%, 20% and 8% at 0°. At 80° the values dropped to 30%, 20%, 12% and 5%. A dependence of the magnitude of the surface dose enhancement on the atomic number of the surface material can be seen, which is in consistence with literature. Conclusion: The results show that the surface dose enhancements near implant materials with high Z-values should be taken into consideration in radio therapy, even when the angle of incidence is flat

  4. Therapeutic doses of radiation alter proliferation and attachment of osteoblasts to implant surfaces.

    Science.gov (United States)

    Ahmad, Mansur; Sampair, Christopher; Nazmul-Hossain, Abu N M; Khurana, Neerja; Nerness, Andrew; Wutticharoenmongkol, Patcharaporn

    2008-09-15

    Osseointegration of implants in irradiated bone is inadequate. The effect of radiation on cell-implant material interaction has not been adequately studied. The goal of this study was to investigate the effects of ionizing radiationon the proliferation, differentiation, and attachment of osteoblasts to commercially pure titanium (cpTi). Human fetal osteoblasts (hFOB) were irradiated either before or after plating in tissue culture (TC) dishes with or without cpTi disks. Radiation was single dose of 10 cGy, 25 cGy, 50 cGy, 1 Gy, 2 Gy, 4 Gy or 8 Gy. Cell proliferation was determined by counting trypsinized cells on 7 days after irradiation. Attachment of irradiated hFOB was measured indirectly by counting cells 2 and 6 h after plating. Differentiation was evaluated by alkaline phosphatase activity. Compared with nonirradiated sham controls, higher doses of radiation significantly reduced cell attachment and proliferation. Both proliferation and attachment were significantly lower on cpTi compared with TC. Attachment decreased based on the length of postirradiation period. Although differentiation was significantly enhanced by a dose of 8 Gy, proliferation was lowest. These initial studies show that effects of therapeutic doses of radiation on osteoblasts varied depending on the surface, time-elapsed, and amount of radiation.

  5. Patient doses in computed tomography: An assessment of local diagnostic reference levels in a large teaching hospital

    Directory of Open Access Journals (Sweden)

    Hadnađev Darka R.

    2012-01-01

    Full Text Available This paper presents an estimation of local diagnostic reference levels in computed tomography in a large teaching hospital. Local diagnostic reference levels, expressed in terms of volume weighted computed tomography dose index and dose-length product, were estimated for three most frequent adult computer tomography examinations: head, abdomen and pelvis combined, and thorax. The established local diagnostic reference levels values were similar or slightly higher compared to the available guidelines, indicating the possibility for optimization of current practice. Analyzing the protocols used here and recently published studies on dose reduction in computed tomography, a dose-reduction technique, was proposed to decrease tube current values in all three examinations. However, the optimization should be restricted only to standard-sized patients.

  6. Natural Radioactivity and External Dose Assessment of Surface Soils in Vietnam

    International Nuclear Information System (INIS)

    Huy, N.Q.; Hien, P.D.; Hoang, D.V.; Quang, N.H.; Long, N.Q.; Binh, N.T.; Hai, P.S.

    2012-01-01

    In this study, natural radioactivity in surface soils of Vietnam and external dose assessment to human population, deduces from activities of 226 Ra, 232 Th and 40 K nuclides, were determined. From 528 soil samples collected in 63 provinces of Vietnam, including five centrally governed cities, the average activities were obtained and equal to 42.77 ± 18.15 Bq kg -1 for 226 Ra, 59.84 ± 19.81 Bq kg -1 for 232 Th and 411.93 ± 230.69 Bq kg -1 for 40 K. The outdoor absorbed dose rates (OADRs) in air at 1 m above the ground level for 63 provinces were calculated, and their average value was 71.72 ± 24.72 nGy h -1 , with a range from 17.45 to 149.40 nGy h -1 . The population-weighted OADR of Vietnam was 66.70 nGy h -1 , which lies in the range of 18-93 nGy h -1 found in the World. From the OADR obtained, it was estimated that the outdoor annual effective dose and indoor annual effective dose to the population were 0.082 and 0.458 mSv, which are higher than the corresponding values 0.07 and 0.41 mSv, respectively, of the World. The radium equivalent activity Ra eq and the external hazard index H ex of surface soils of Vietnam are lower than the corresponding permissible limits of 370 Bq kg -1 and 1, respectively. Therefore, soil from Vietnam is safe for the human population when it used as a building material. (author)

  7. Natural radioactivity and external dose assessment of surface soils in Vietnam

    International Nuclear Information System (INIS)

    Huy, N. Q.; Hien, P. D.; Luyen, T. V.; Hoang, D. V.; Hiep, H. T.; Quang, N. H.; Long, N. Q.; Nhan, D. D.; Binh, N. T.; Hai, P. S.; Ngo, N. T.

    2012-01-01

    In this study, natural radioactivity in surface soils of Vietnam and external dose assessment to human population, deduced from activities of 226 Ra, 232 Th and 40 K nuclides, were determined. From 528 soil samples collected in 63 provinces of Vietnam, including five centrally governed cities, the average activities were obtained and equal to 42.77 ± 18.15 Bq kg -1 for 226 Ra, 59.84 ± 19.81 Bq kg -1 for 232 Th and 411.93 ± 230.69 Bq kg -1 for 40 K. The outdoor absorbed dose rates (OADRs) in air at 1 m above the ground level for 63 provinces were calculated, and their average value was 71.72 ± 24.72 nGy h -1 , with a range from 17.45 to 149.40 nGy h -1 . The population-weighted OADR of Vietnam was 66.70 nGy h -1 , which lies in the range of 18-93 nGy h -1 found in the World. From the OADRs obtained, it was estimated that the outdoor annual effective dose and indoor annual effective dose to the population were 0.082 and 0.458 mSv, which are higher than the corresponding values 0.07 and 0.41 mSv, respectively, of the World. The radium equivalent activity Ra eq and the external hazard index H ex of surface soils of Vietnam are lower than the corresponding permissible limits of 370 Bq kg -1 and 1, respectively. Therefore, soil from Vietnam is safe for the human population when it is used as a building material. (authors)

  8. Response surfaces and sensitivity analyses for an environmental model of dose calculations

    International Nuclear Information System (INIS)

    Iooss, Bertrand; Van Dorpe, Francois; Devictor, Nicolas

    2006-01-01

    A parametric sensitivity analysis is carried out on GASCON, a radiological impact software describing the radionuclides transfer to the man following a chronic gas release of a nuclear facility. An effective dose received by age group can thus be calculated according to a specific radionuclide and to the duration of the release. In this study, we are concerned by 18 output variables, each depending of approximately 50 uncertain input parameters. First, the generation of 1000 Monte-Carlo simulations allows us to calculate correlation coefficients between input parameters and output variables, which give a first overview of important factors. Response surfaces are then constructed in polynomial form, and used to predict system responses at reduced computation time cost; this response surface will be very useful for global sensitivity analysis where thousands of runs are required. Using the response surfaces, we calculate the total sensitivity indices of Sobol by the Monte-Carlo method. We demonstrate the application of this method to one site of study and to one reference group near the nuclear research Center of Cadarache (France), for two radionuclides: iodine 129 and uranium 238. It is thus shown that the most influential parameters are all related to the food chain of the goat's milk, in decreasing order of importance: dose coefficient 'effective ingestion', goat's milk ration of the individuals of the reference group, grass ration of the goat, dry deposition velocity and transfer factor to the goat's milk

  9. Non-coplanar beam intensity modulation allows large dose escalation in stage III lung cancer

    International Nuclear Information System (INIS)

    Derycke, Sylvie; Van Duyse, Bart; De Gersem, Werner; De Wagter, Carlos; De Neve, Wilfried

    1997-01-01

    Purpose: To evaluate the feasibility of dose escalation in stage III non-small cell lung cancer, we compared standard coplanar (2D) with non-coplanar beam arrangements, without (3D) and with beam intensity modulation (3D-BIM). Materials and methods: This study was a planning effort performed on a non-selected group of 10 patients. Starting from a serial CT scan, treatment planning was performed using Sherouse's GRATIS TM 3D planning system. Two target volumes were defined; gross tumor volume (GTV) defined a high-dose target volume that had to receive a dose of at least 80 Gy and GTV plus the lymph node regions with >10% probability of invasion defined an intermediate-dose target volume (GTV+N). It was our intention to irradiate GTV+N up to 56 Gy or more. If the prescribed doses on GTV and GTV+N could not be reached with either the 2D or 3D technique, a 3D-BIM plan was performed. The 3D-BIM plan was a class solution involving identical gantry angles, segment arrangements and relative segment weights for all patients. Dose volume histograms for GTV, GTV+N, lung and spinal cord were calculated. Criteria for tolerance were met if no points inside the spinal cord exceeded 50 Gy and if at least 50% of the lung volume received less than 20 Gy. Under these constraints, maximal achievable doses to GTV and GTV+N were calculated. Results: In all 2D plans, spinal cord was the limiting factor and the prescribed doses for GTV and GTV+N could not be reached in any patient. The non-coplanar 3D plan resulted in a satisfying solution in 4 out of 10 patients under the same constraints. In comparison with 2D, the minimum dose in GTV+N was increased. Six patients had to be planned with the 3D-BIM technique. The theoretical minimum dose to GTV+N ranged between 56 and 98 Gy. The delivery of 80 Gy or more to GTV was possible in all patients. For a minimal dose of 80 Gy to GTV, the maximal dose to any point of the spinal cord varied between 27 and 46 Gy. The lung volume receiving more than

  10. Influence of irradiation dose on laser-induced surface nanostructures on silicon

    Energy Technology Data Exchange (ETDEWEB)

    Varlamova, Olga [Brandenburgische Technische Universität BTU Cottbus, Platz der Deutschen Einheit 1, 03046 Cottbus (Germany); Cottbus JointLab, Platz der Deutschen Einheit 1, 03046 Cottbus (Germany); Bounhalli, Mourad [Brandenburgische Technische Universität BTU Cottbus, Platz der Deutschen Einheit 1, 03046 Cottbus (Germany); Laboratoire Hubert Curien, Université St. Etienne, Bâtiment F 18 Rue du Professeur Benoît Lauras, 42000 Saint-Etienne (France); Reif, Juergen, E-mail: REIF@TU-COTTBUS.DE [Brandenburgische Technische Universität BTU Cottbus, Platz der Deutschen Einheit 1, 03046 Cottbus (Germany); Cottbus JointLab, Platz der Deutschen Einheit 1, 03046 Cottbus (Germany)

    2013-08-01

    We report on the dependence of femtosecond laser-induced periodic surface structures on an increase of incident pulse number. On silicon, the patterns evolve from linear, parallel sub-wavelength ripples, grossly perpendicular to the laser polarization, via coalesced wider features parallel to the polarization, to a crater with periodically structured, pillar-like walls. Closer inspection of the patterns indicates that the different features always continue to exhibit reminiscence to the preceding lower-dose patterns, suggesting that, indeed, all patterns can be created by ONE single GENERAL formation process, as in self-organized structure formation, and the different structures/feature sizes are NOT due to DIFFERENT mechanisms.

  11. Influence of irradiation dose on laser-induced surface nanostructures on silicon

    International Nuclear Information System (INIS)

    Varlamova, Olga; Bounhalli, Mourad; Reif, Juergen

    2013-01-01

    We report on the dependence of femtosecond laser-induced periodic surface structures on an increase of incident pulse number. On silicon, the patterns evolve from linear, parallel sub-wavelength ripples, grossly perpendicular to the laser polarization, via coalesced wider features parallel to the polarization, to a crater with periodically structured, pillar-like walls. Closer inspection of the patterns indicates that the different features always continue to exhibit reminiscence to the preceding lower-dose patterns, suggesting that, indeed, all patterns can be created by ONE single GENERAL formation process, as in self-organized structure formation, and the different structures/feature sizes are NOT due to DIFFERENT mechanisms.

  12. Evolution of Entrance Surface Doses and Image Quality in Pediatric Chest Radiographs

    International Nuclear Information System (INIS)

    Campello, A.C.; Marques, D.T.; Medeiros, C.B.; Carvalho, P.P.; Khoury, H.J.; Azevedo, A.C.P.

    2006-01-01

    This work presents the results of a survey about image quality, radiographic techniques and patient doses in a large public hospital located in the city of Recife, Brazil. It was detected that the quality criteria are not fully reached and represent 70% of the agreement with recommendations from the European Community. Concerning the radiographic techniques the kV is in accordance with international recommendations in 90% if the examinations while the exposure time is 72%. The results also show that the dose values change in the range from 0.020 to 0.250 mGy. The variability is mainly caused by the disparity on the radiographic techniques employed in the examinations as well as by the radiographer's expertise. It could be concluded that the ALARA principle is not being applied in the hospital, which becomes a concern in terms of public health. (author)

  13. Passive Rn dose meters - measuring methods appropriate for large measurement series

    International Nuclear Information System (INIS)

    Urban, M.; Kiefer, H.

    1985-01-01

    Passive integrating measuring methods can be classified in several groups by their functioning principle, e.g. spray chambers or open chambers with nuclear trace detectors or TL detectors, open detectors, activated carbon dose meters with or without TL detectors. According to the functioning principle, only radon or radon and fission products can be detected. The lecture gives a survey of the present state of development of passive Rn dose meters. By the example of the Ra dose meter developed at Karlsruhe which was used in inquiry measurements carried out in Germany, Switzerland, the Netherlands, Belgium and Austria, etching technology, estimation of measuring uncertainties, reproducibility and fading behaviour shall be discussed. (orig./HP) [de

  14. Internal dose assessment due to large area contamination: Main lessons drawn from the Chernobyl accident

    International Nuclear Information System (INIS)

    Andrasi, A.

    1997-01-01

    The reactor accident at Chernobyl in 1986 beside its serious and tragic consequences provided also an excellent opportunity to check, test and validate all kind of environmental models and calculation tools which were available in the emergency preparedness systems of different countries. Assessment of internal and external doses due to the accident has been carried out for the population all over Europe using different methods. Dose predictions based on environmental model calculation considering various pathways have been compared with those obtained by more direct monitoring methods. One study from Hungary and one from the TAEA is presented shortly. (orig./DG)

  15. Internal dose assessment due to large area contamination: Main lessons drawn from the Chernobyl accident

    Energy Technology Data Exchange (ETDEWEB)

    Andrasi, A. [KFKI Atomic Energy Research Inst., Budapest (Hungary)

    1997-03-01

    The reactor accident at Chernobyl in 1986 beside its serious and tragic consequences provided also an excellent opportunity to check, test and validate all kind of environmental models and calculation tools which were available in the emergency preparedness systems of different countries. Assessment of internal and external doses due to the accident has been carried out for the population all over Europe using different methods. Dose predictions based on environmental model calculation considering various pathways have been compared with those obtained by more direct monitoring methods. One study from Hungary and one from the TAEA is presented shortly. (orig./DG)

  16. Developing equations to predict surface dose and therapeutic interval in bolused electron fields: A Monte Carlo Study

    Science.gov (United States)

    Jabbari, Nasrollah; Khalkhali, Hamid Reza

    2017-07-01

    In this research, we aim to investigate the influence of different materials, as a bolus, on the low-energy electron beam dose distributions and to develop equations for predicting surface dose based on bolus thickness, as well as the therapeutic interval based on surface dose. All the Monte Carlo (MC) calculations and measurements were conducted on a Siemens PRIMUS linac. Based on EGSnrc MC code, BEAMnrc system was used to model a Siemens linac and generate phase-space files for three electron beams (6, 8, and 10 MeV). The particles were transported from the phase-space files to the bolus materials and the simulated water phantom using DOSXYZnrc. Various materials with different thicknesses were examined as a bolus, and appropriate equations were determined for each material and electron beam. The comparison of percent depth dose (PDD) curves and beam profiles, using MC, with the measured data demonstrated that the calculated values properly matched with the measurements. The results indicated that the use of bolus materials with the density of higher than soft tissue can increase both surface dose and therapeutic interval simultaneously. This finding arises from the fact that the required bolus thickness for achieving the therapeutic surface dose decreases in the case of high-density materials. Two series of prediction equations were proposed for predicting the surface dose based on bolus thickness and the therapeutic interval based on surface dose. These equations are able to calculate properly the bolus thickness required for producing a therapeutic surface dose (above 90%) for any therapeutic interval.

  17. Dose-response relationship between periodontal inflamed surface area and HbA1c in type 2 Diabetics

    NARCIS (Netherlands)

    Nesse, Willem; Linde, Annemiek; Abbas, Frank; Spijkervet, Frederik Karst Lucien; Dijkstra, Pieter Ubele; de Brabander, Eric Carl; Gerstenbluth, Izzy; Vissink, Arjan

    Nesse W, Linde A, Abbas F, Spijkervet FKL, Dijkstra PU, de Brabander EC, Gerstenbluth I, Vissink A. Dose-response relationship between periodontal inflamed surface area and HbA1c in type 2 diabetics. J Clin Periodontol 2009; 36: 295-300. doi: 10.1111/j.1600-051X.2009.01377.x. A dose-response

  18. Modeling Urinary Dysfunction After External Beam Radiation Therapy of the Prostate Using Bladder Dose-Surface Maps: Evidence of Spatially Variable Response of the Bladder Surface.

    Science.gov (United States)

    Yahya, Noorazrul; Ebert, Martin A; House, Michael J; Kennedy, Angel; Matthews, John; Joseph, David J; Denham, James W

    2017-02-01

    We assessed the association of the spatial distribution of dose to the bladder surface, described using dose-surface maps, with the risk of urinary dysfunction. The bladder dose-surface maps of 754 participants from the TROG 03.04-RADAR trial were generated from the volumetric data by virtually cutting the bladder at the sagittal slice, intersecting the bladder center-of-mass through to the bladder posterior and projecting the dose information on a 2-dimensional plane. Pixelwise dose comparisons were performed between patients with and without symptoms (dysuria, hematuria, incontinence, and an International Prostate Symptom Score increase of ≥10 [ΔIPSS10]). The results with and without permutation-based multiple-comparison adjustments are reported. The pixelwise multivariate analysis findings (peak-event model for dysuria, hematuria, and ΔIPSS10; event-count model for incontinence), with adjustments for clinical factors, are also reported. The associations of the spatially specific dose measures to urinary dysfunction were dependent on the presence of specific symptoms. The doses received by the anteroinferior and, to lesser extent, posterosuperior surface of the bladder had the strongest relationship with the incidence of dysuria, hematuria, and ΔIPSS10, both with and without adjustment for clinical factors. For the doses to the posteroinferior region corresponding to the area of the trigone, the only symptom with significance was incontinence. A spatially variable response of the bladder surface to the dose was found for symptoms of urinary dysfunction. Limiting the dose extending anteriorly might help reduce the risk of urinary dysfunction. Copyright © 2016. Published by Elsevier Inc.

  19. Surface dose measurements under stretched, perforated thermoplast sheets and under protective wound dressings for high energy photon radiation

    International Nuclear Information System (INIS)

    Staudenraus, J.; Christ, G.

    2000-01-01

    Patient fixation masks made of perforated thermoplast sheets are widely used in radiotherapy. These masks in particular serve to immobilize the head and neck region during radiation treatment. We placed samples made of differently stretched, perforated mask material on the surface of a white polystyrene (RW3) phantom and measured for high energy photon beams from Co-60 radiation up to 25 MV bremsstrahlung the dose increase resulting from the build-up under the hole and bridge areas. Depending on the energy of the incident beam and the thickness of the stretched mask material we observed a dose increase under the bridges at the phantom surface of 55% up to 140% compared to the dose without a layer of mask material. Under a hole the dose increase is almost half the value found under a bridge. However, deeper than 1 mm under the phantom surface this difference in dose increase under holes and bridges decreases to less than 10%. The mean dose increase under a perforated thermoplast sheet is lower than the dose increase under a homogeneous sheet made of the same material with the same mean thickness. Radiation induced skin lesions or an ulcerating tumour, respectively, may require a protective wound dressing under a patient fixation mask during radiation therapy. Choosing a thin hydrocolloid wound dressing the additional dose increase of the skin, compared to the dose increase due to the fixation mask, can be kept low. (orig.) [de

  20. Modeling dose-rate on/over the surface of cylindrical radio-models using Monte Carlo methods

    International Nuclear Information System (INIS)

    Xiao Xuefu; Ma Guoxue; Wen Fuping; Wang Zhongqi; Wang Chaohui; Zhang Jiyun; Huang Qingbo; Zhang Jiaqiu; Wang Xinxing; Wang Jun

    2004-01-01

    Objective: To determine the dose-rates on/over the surface of 10 cylindrical radio-models, which belong to the Metrology Station of Radio-Geological Survey of CNNC. Methods: The dose-rates on/over the surface of 10 cylindrical radio-models were modeled using the famous Monte Carlo code-MCNP. The dose-rates on/over the surface of 10 cylindrical radio-models were measured by a high gas pressurized ionization chamber dose-rate meter, respectively. The values of dose-rate modeled using MCNP code were compared with those obtained by authors in the present experimental measurement, and with those obtained by other workers previously. Some factors causing the discrepancy between the data obtained by authors using MCNP code and the data obtained using other methods are discussed in this paper. Results: The data of dose-rates on/over the surface of 10 cylindrical radio-models, obtained using MCNP code, were in good agreement with those obtained by other workers using the theoretical method. They were within the discrepancy of ±5% in general, and the maximum discrepancy was less than 10%. Conclusions: As if each factor needed for the Monte Carlo code is correct, the dose-rates on/over the surface of cylindrical radio-models modeled using the Monte Carlo code are correct with an uncertainty of 3%

  1. Low-Stress Silicon Cladding for Surface Finishing Large UVOIR Mirrors Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase I research, ZeCoat Corporation demonstrated a low-stress silicon cladding process for surface finishing large UVOIR mirrors. A polishable cladding is...

  2. Surface and Internal Waves due to a Moving Load on a Very Large Floating Structure

    Directory of Open Access Journals (Sweden)

    Taro Kakinuma

    2012-01-01

    Full Text Available Interaction of surface/internal water waves with a floating platform is discussed with nonlinearity of fluid motion and flexibility of oscillating structure. The set of governing equations based on a variational principle is applied to a one- or two-layer fluid interacting with a horizontally very large and elastic thin plate floating on the water surface. Calculation results of surface displacements are compared with the existing experimental data, where a tsunami, in terms of a solitary wave, propagates across one-layer water with a floating thin plate. We also simulate surface and internal waves due to a point load, such as an airplane, moving on a very large floating structure in shallow water. The wave height of the surface or internal mode is amplified when the velocity of moving point load is equal to the surface- or internal-mode celerity, respectively.

  3. Electron dose-rate conversion factors for external exposure of the skin from uniformly deposited activity on the body surface

    International Nuclear Information System (INIS)

    Kocher, D.C.; Eckerman, K.F.

    1987-01-01

    Dose-rate conversion factors have been calculated for external exposure of the skin from electrons emitted by sources that are deposited uniformly on the body surface. The dose-rate factors are obtained from electron scaled point kernels developed by Berger. The dose-rate factors are calculated at depths of 4, 8, and 40 mg cm-2 below the body surface as recommended by Whitton, and at a depth of 7 mg cm-2 as recommended in ICRP Publication 26 (ICRP77). The dependence of the dose-rate factors at selected depths on the energy of the emitted electrons is displayed. The dose-rate factors for selected radionuclides of potential importance in radiological assessments are tabulated

  4. Field Investigation of the Surface-deposited Radon Progeny as a Possible Predictor of the Airborne Radon Progeny Dose Rate

    Science.gov (United States)

    Sun, Kainan; Steck, Daniel J.; Field, R. William

    2009-01-01

    The quantitative relationships between radon gas concentration, the surface-deposited activities of various radon progeny, the airborne radon progeny dose rate, and various residential environmental factors were investigated through actual field measurements in 38 selected Iowa houses occupied by either smokers or nonsmokers. Airborne dose rate was calculated from unattached and attached potential alpha energy concentrations (PAECs) using two dosimetric models with different activity-size weighting factors. These models are labeled Pdose and Jdose, respectively. Surface-deposited 218Po and 214Po were found significantly correlated to radon, unattached PAEC, and both airborne dose rates (p fireplace, or usage of a ceiling fan significantly, or marginal significantly, reduced the Pdose to 0.65 (90% CI 0.42–0.996), 0.54 (90% CI 0.28–1.02) and 0.66 (90% CI 0.45–0.96), respectively. For Jdose, only the usage of a ceiling fan significantly reduced the dose rate to 0.57 (90% CI 0.39–0.85). In smoking environments, deposited 218Po was a significant negative predictor for Pdose (RR 0.68, 90% CI 0.55–0.84) after adjusting for long-term 222Rn and environmental factors. A significant decrease of 0.72 (90% CI 0.64–0.83) in the mean Pdose was noted, after adjusting for the radon and radon progeny effects and other environmental factors, for every 10 increasing cigarettes smoked in the room. A significant increase of 1.71 in the mean Pdose was found for large room size relative to small room size (90% CI 1.08–2.79) after adjusting for the radon and radon progeny effects as well as other environmental factors. Fireplace usage was found to significantly increase the mean Pdose to 1.71 (90% CI 1.20–2.45) after adjusting for other factors. PMID:19590273

  5. SU-E-T-348: Effect of Treatment Table and Immobilization Devices On Surface Dose When Using a GRID Technique

    Energy Technology Data Exchange (ETDEWEB)

    Gajdos, S; Donaghue, J [Akron General Medical Center, Akron, OH (United States)

    2015-06-15

    Purpose: To determine the increase of surface dose of MLC-designed GRID therapy in the presence of immobilization devices and treatment table. Methods: To create a GRID field, our facility utilizes an MLC consisting of four millimeter wide leaves. The field is designed to have aperture sizes of 0.8 cm X 0.8 cm with inter-aperture distance of 3.2 cm. Gafchromic EBT3 film was placed between the surface of a solid water phantom and the immobilization device. The treatment table was also present within the beam path. The devices consist of carbon fiber exterior shell. A piece of film was also placed at maximal depth for the photon energy of 10 MV. Image files were converted to dose per a calibration curve based on the selected red channel. The surface dose to maximum dose was established by comparing the ratio of seven centrally located aperture regions-of-interest and four adjacent inter-aperture regions-of-interest were measured with the available software tools. Results: With no devices present in beam path, the ratio of surface dose to maximum dose was 11.5% ± 0.3% for aperture region and 7.0% ± 0.1% for inter-aperture region. When devices are present, the ratio of surface dose to maximum dose was 45.2% ± 0.5% and 33.8% ± 1.1%, respectively. Due to the presence of devices, the surface dose increases in aperture region by 3.8 times or in the inter-aperture region by 4.7 times. Conclusion: The purpose of using GRID technique is to deliver a single fractional dose in range of 15–20 Gy to a bulky lesion while also preserving skin tolerance. The increase of surface dose due to devices placed in beam path may increase the chance of skin toxicity in GRID therapy. Care should be used to determine best manageable patient immobilization while considering skin dose especially for posteriorly located lesions.

  6. The influence of single low dose of recombinant human thyrotropin on I-131 treatment of large multi-nodular goitre

    International Nuclear Information System (INIS)

    Mojsak, M.N.; Abdelrazek, S.; Rogowski, F.; Szunowski, P.; Mysliwiec, J.; Kociura-Sawicka, A.

    2015-01-01

    Full text of publication follows. Recombinant human thyrotropin (rhTSH) is a substance that after single intramuscular injection can increase thyroid radioiodine uptake (RAIU) and improve the results of radioiodine therapy (RIT) in patients with nontoxic multi-nodular goitre (MNG). These effects are very important especially in cases of large MNG with relatively low RAIU or contraindications to surgery. The aim of the study: the evaluation of the influence of the single low dose of rhTSH to RAIU and the effects of RIT in patients with benign large nontoxic MNG. Material and methods: 40 patients (14 male, 26 female, age 41-80 yr) with large MNG > 100 grams and with baseline RAIU < 40% (33,37±7,96%) were included to the study and divided into two groups. First group received the single intramuscular injection of 0,03 mg rhTSH and the second received placebo. The RAIU were measured again 48 hours after the rhTSH (24 hours after diagnostic dose of I-131). After this, all the patients were administered the therapeutic doses of I-131 recalculated according to new RAIU. The patients follow up was continued for minimum 12 months. Results: the mean RAIU after rhTSH increased more than twice, to 75% from 33%. One year after RIT the mean volume goitre reduction were significantly greater in group with rhTSH than in patients with placebo (48±16% vs. 37±18%). Decrease of compression symptoms has taken place earlier and was more important in patients after rhTSH. 12 months after RIT two patients stay in hypothyroid state (from the group with rhTSH), other patients are euthyroid. Conclusions: even the single very low dose of rhTSH increases the values of RAIU in significant way. Efficacy of rhTSH-augmented RIT in patients with large nontoxic MNG is greater than standard RIT. It allows to reduce administered doses of I-131, decreases the need of repeating RIT, makes the radiation adsorbed doses for whole body lower and the RIT shorter. (authors)

  7. Misonidazole cytotoxicity in vivo: a comparison of large single doses with smaller doses and extended contact of the drug with tumor cells

    International Nuclear Information System (INIS)

    Conroy, P.J.; Sutherland, R.M.; Passalacqua, W.

    1980-01-01

    Experiments were performed to determine the kinetics and magnitude of misonidazole cytotoxicity in EMT6/Ro tumors using an in vivo-in vitro clonogenicity assay. A comparison was made between the cytotoxic effects of large single doses with smaller doses of misonidazole administered ip and those produced on extended contact of the drug with tumor cells using a continuous iv drug infusion system. After a single ip dose of 1 mg/g, cytotoxicity was maximum at 18 to 24 h; by 72 h the clonogenic cells per tumor had returned to control levels. The maximum cytotoxicity was greater (a decrease of 10 times) if the animals were kept at 37 0 C compared with ambient conditions (a decrease of 4.5 times) where the body temperature would decrease due to the drug. A dose-response curve performed with the animals at 37 0 C showed no significant cytotoxicity at 18 h after single ip doses of 0.5 mg/g or less. Other experiments were carried out at 37 0 C using a drug continuous infusion system. Two profiles were studied: (a) continuous constant rate infusion over 3 days of constant serum and tumor levels of both 100 and 200 μg/ml and (b) continuous variable rate infusion where the maximum serum levels reached 80 or 200 μg/ml after 2 to 4 h and decayed with a half-life of 12 h as in humans. Significant cytotoxicity was obtained under both of these conditions. Maximum cytotoxicity occurred at about 24 h in both types of experiments and amounted to decreases of clonogenic tumor cells of 4.5 and 7 times for 100 and 200 μg/ml, respectively, after constant rate infusion and 2 to 4 times for 80 and 200 μg/ml, respectively, after variable rate infusion. Because of the relatively rapid recovery in the number of clonogenic tumor cells by 72 h, the cytotoxic effects were not reflected as changes in tumor size even when the animals were maintained at 37 0 C

  8. Large-area electromagnetic enhancement by a resonant excitation of surface waves on a metallic surface with periodic subwavelength patterns.

    Science.gov (United States)

    Zhang, Xin; Liu, Haitao; Zhong, Ying

    2013-10-07

    We theoretically investigate the electromagnetic enhancement on a metallic surface patterned with periodic subwavelength structures. Fully-vectorial calculations show a large-area electromagnetic enhancement (LAEE) on the surface, which strongly contrasts with the previously reported "hot spots" that occur in specific tiny regions and which relieves the rigorous requirement of the nano-scale location of sample molecules. The LAEE allows for designing more practicable substrates for many enhanced-spectra applications. By building up microscopic models, the LAEE is shown due to a resonant excitation of surface waves that include both the surface plasmon polariton (SPP) and a quasi-cylindrical wave (QCW). The surface waves propagate on the substrate over a long distance and thus greatly enlarge the area of electromagnetic enhancement compared to the nano-sized hot spots caused by localized modes. Gain medium is introduced to further strengthen the large-area surface-wave resonance, with which an enhancement factor (EF) of electric-field intensity up to a few thousands is achieved.

  9. Effect of surface roughness on the heating rates of large-angled hypersonic blunt cones

    Science.gov (United States)

    Irimpan, Kiran Joy; Menezes, Viren

    2018-03-01

    Surface-roughness caused by the residue of an ablative Thermal Protection System (TPS) can alter the turbulence level and surface heating rates on a hypersonic re-entry capsule. Large-scale surface-roughness that could represent an ablated TPS, was introduced over the forebody of a 120° apex angle blunt cone, in order to test for its influence on surface heating rates in a hypersonic freestream of Mach 8.8. The surface heat transfer rates measured on smooth and roughened models under the same freestream conditions were compared. The hypersonic flow-fields of the smooth and rough-surfaced models were visualized to analyse the flow physics. Qualitative numerical simulations and pressure measurements were carried out to have an insight into the high-speed flow physics. Experimental observations under moderate Reynolds numbers indicated a delayed transition and an overall reduction of 17-46% in surface heating rates on the roughened model.

  10. Utility of Activation Detectors for the Assessment of Large Doses from High-Energy Particles

    International Nuclear Information System (INIS)

    Sklavenitis, L.

    1965-01-01

    Threshold detectors are used to evaluate the neutron doses received from exposure to high fluxes (e.g. criticality accidents). Use of the same principle in the dosimetry of very high-energy particles produced by accelerators is beset by considerable difficulties because, after a few tens of MeV, protons penetrate the Coulomb barrier and react with nuclei, like neutrons. Mesons created by high-energy reactions, and the associated electromagnetic quanta, are also capable of producing nuclear reactions. Moreover, in this energy range, each nuclear reaction is in competition with several others and a particle striking the nucleus has a definite probability of producing all the isotopes with mass numbers lower than that of the target. In spite of these complications, the shape of the curves of certain reaction cross-sections, in relation to energy, points to the possibility of using activation detectors for approximate spectral analysis of the radiation field and for flux calculations. Although our present knowledge of very high-energy reactions and the values of the corresponding cross sections is inadequate, particularly as regards neutrons and relativistic particles, it is nevertheless sufficient to enable us to make a preliminary choice of activation detectors providing, with sufficient accuracy for radiological protection purposes, an estimate of the mean fluxes of particles in various energy ranges and thus the doses absorbed. (author) [fr

  11. Individual fluorouracil dose adjustment in FOLFOX based on pharmacokinetic follow-up compared with conventional body-area-surface dosing: a phase II, proof-of-concept study.

    Science.gov (United States)

    Capitain, Olivier; Asevoaia, Andreaa; Boisdron-Celle, Michele; Poirier, Anne-Lise; Morel, Alain; Gamelin, Erick

    2012-12-01

    To compare the efficacy and safety of pharmacokinetically (PK) guided fluorouracil (5-FU) dose adjustment vs. standard body-surface-area (BSA) dosing in a FOLFOX (folinic acid, fluorouracil, oxaliplatin) regimen in metastatic colorectal cancer (mCRC). A total of 118 patients with mCRC were administered individually determined PK-adjusted 5-FU in first-line FOLFOX chemotherapy. The comparison arm consisted of 39 patients, and these patients were also treated with FOLFOX with 5-FU by BSA. For the PK-adjusted arm 5-FU was monitored during infusion, and the dose for the next cycle was based on a dose-adjustment chart to achieve a therapeutic area under curve range (5-FU(ODPM Protocol)). The objective response rate was 69.7% in the PK-adjusted arm, and median overall survival and median progression-free survival were 28 and 16 months, respectively. In the traditional patients who received BSA dosage, objective response rate was 46%, and overall survival and progression-free survival were 22 and 10 months, respectively. Grade 3/4 toxicity was 1.7% for diarrhea, 0.8% for mucositis, and 18% for neutropenia in the dose-monitored group; they were 12%, 15%, and 25%, respectively, in the BSA group. Efficacy and tolerability of PK-adjusted FOLFOX dosing was much higher than traditional BSA dosing in agreement with previous reports for 5-FU monotherapy PK-adjusted dosing. Analysis of these results suggests that PK-guided 5-FU therapy offers added value to combination therapy for mCRC. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Radiolysis of aqueous solutions of ammonium bicarbonate over a large dose range

    DEFF Research Database (Denmark)

    Draganic, Z.D.; Negrón-Mendoza, A.; Sehested, K.

    1991-01-01

    Oxygen-free aqueous solutions of 0.05 mol dm-3 ammonium and sodium bicarbonate were studied after receiving various doses of Co-60 gammas (0.01-400 kGy) or 0.5-20 Gy pulses of 10 Mev electrons. Formate and oxalate were found to be the main radiolytic products, in addition to trace amounts...... to the reformation of bicarbonate, where the reaction COO- + CO3- is particularly significant. Computer fitting of the data obtained gives k(COO- + HCO3-) = (2 +/- 0.4) x 10(3) dm3 mol-1 s-1, k(COO- + CO3-) = (5 +/- 1) x 10(7) dm3 mol-1 s-1, k(NH2 + HCO3-)

  13. Spatial features of dose-surface maps from deformably-registered plans correlate with late gastrointestinal complications

    Science.gov (United States)

    Moulton, Calyn R.; House, Michael J.; Lye, Victoria; Tang, Colin I.; Krawiec, Michele; Joseph, David J.; Denham, James W.; Ebert, Martin A.

    2017-05-01

    This study investigates the associations between spatial distribution of dose to the rectal surface and observed gastrointestinal toxicities after deformably registering each phase of a combined external beam radiotherapy (EBRT)/high-dose-rate brachytherapy (HDRBT) prostate cancer treatment. The study contains data for 118 patients where the HDRBT CT was deformably-registered to the EBRT CT. The EBRT and registered HDRBT TG43 dose distributions in a reference 2 Gy/fraction were 3D-summed. Rectum dose-surface maps (DSMs) were obtained by virtually unfolding the rectum surface slice-by-slice. Associations with late peak gastrointestinal toxicities were investigated using voxel-wise DSM analysis as well as parameterised spatial patterns. The latter were obtained by thresholding DSMs from 1-80 Gy (increment  =  1) and extracting inferior-superior extent, left-right extent, area, perimeter, compactness, circularity and ellipse fit parameters. Logistic regressions and Mann-Whitney U-tests were used to correlate features with toxicities. Rectal bleeding, stool frequency, diarrhoea and urgency/tenesmus were associated with greater lateral and/or longitudinal spread of the high doses near the anterior rectal surface. Rectal bleeding and stool frequency were also influenced by greater low-intermediate doses to the most inferior 20% of the rectum and greater low-intermediate-high doses to 40-80% of the rectum length respectively. Greater low-intermediate doses to the superior 20% and inferior 20% of the rectum length were associated with anorectal pain and urgency/tenesmus respectively. Diarrhoea, completeness of evacuation and proctitis were also related to greater low doses to the posterior side of the rectum. Spatial features for the intermediate-high dose regions such as area, perimeter, compactness, circularity, ellipse eccentricity and confinement to ellipse fits were strongly associated with toxicities other than anorectal pain. Consequently, toxicity is

  14. Quantification of acute vocal fold epithelial surface damage with increasing time and magnitude doses of vibration exposure.

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Kojima

    Full Text Available Because the vocal folds undergo repeated trauma during continuous cycles of vibration, the epithelium is routinely susceptible to damage during phonation. Excessive and prolonged vibration exposure is considered a significant predisposing factor in the development of vocal fold pathology. The purpose of the present study was to quantify the extent of epithelial surface damage following increased time and magnitude doses of vibration exposure using an in vivo rabbit phonation model. Forty-five New Zealand white breeder rabbits were randomized to nine groups and received varying phonation time-doses (30, 60, or 120 minutes and magnitude-doses (control, modal intensity phonation, or raised intensity phonation of vibration exposure. Scanning electron microscopy and transmission electron microscopy was used to quantify the degree of epithelial surface damage. Results revealed a significant reduction in microprojection density, microprojection height, and depth of the epithelial surface with increasing time and phonation magnitudes doses, signifying increased epithelial surface damage risk with excessive and prolonged vibration exposure. Destruction to the epithelial cell surface may provide significant insight into the disruption of cell function following prolonged vibration exposure. One important goal achieved in the present study was the quantification of epithelial surface damage using objective imaging criteria. These data provide an important foundation for future studies of long-term tissue recovery from excessive and prolonged vibration exposure.

  15. Environmental dose level survey of radiotherapy center in large cancer hospital

    International Nuclear Information System (INIS)

    Wan Bin; Zhong Hailuo; Wu Dake; Li Jian; Wang Pei; Qi Guohai; Huang Renbing; Lang Jinyi

    2009-01-01

    Objective: To investigate and analyze the radiation dosage around the working environment in radiotherapy centre affiliated to Sichuan cancer hospital in the western China. Methods: In 60 days, we have continuously monitored the accumulated dose that absorbed by doctors, nurses, technicians, physicists and engineers, and investigated the working environment ( 60 Co unit, accelerator, after loading unit, X-ray simulator, CT simulator, gamma knife, MRI and doctor's office) and external environment by using TLD, and compared our results to those released by relevant departments. Results: The average dosage in the working environment is 1.96 μC ·kg -1 ·month -1 , 1.61 μC ·kg -1 ·month -1 in external environment. Conclusion: In the past 25 years, the radiotherapy center constructed strictly by the criterions of environment and protection departments required, so the radiation dosage in or outside the radiotherapy center has reached the national standard, which is safe for the staff and patients. Its instatement that the radiotherapy sites constructed by the related laws well accorded with the safety standards regulated. (authors)

  16. Large dose hyperpolarized water with dissolution-DNP at high magnetic field

    DEFF Research Database (Denmark)

    Lipsø, Hans Kasper Wigh; Bowen, Sean; Rybalko, Oleksandr

    2016-01-01

    We demonstrate a method for the preparation of hyperpolarized water by dissolution Dynamic Nuclear Polarization at high magnetic field. Protons were polarized at 6.7T and 1.1K to >70% with frequency modulated microwave irradiation at 188GHz. 97.2±0.7% of the radical was extracted from the sample...... was polarized and dissolved in a fluid path compatible with clinical polarizers. The volume of hyperpolarized water produced by this method enables angiography and perfusion measurements in large animals, as well as NMR experiments for studies of e.g. proton exchange and polarization transfer to other nuclei....

  17. Estimating patient dose from x-ray tube output metrics: automated measurement of patient size from CT images enables large-scale size-specific dose estimates.

    Science.gov (United States)

    Ikuta, Ichiro; Warden, Graham I; Andriole, Katherine P; Khorasani, Ramin; Sodickson, Aaron

    2014-02-01

    To test the hypothesis that patient size can be accurately calculated from axial computed tomographic (CT) images, including correction for the effects of anatomy truncation that occur in routine clinical CT image reconstruction. Institutional review board approval was obtained for this HIPAA-compliant study, with waiver of informed consent. Water-equivalent diameter (D(W)) was computed from the attenuation-area product of each image within 50 adult CT scans of the thorax and of the abdomen and pelvis and was also measured for maximal field of view (FOV) reconstructions. Linear regression models were created to compare D(W) with the effective diameter (D(eff)) used to select size-specific volume CT dose index (CTDI(vol)) conversion factors as defined in report 204 of the American Association of Physicists in Medicine. Linear regression models relating reductions in measured D(W) to a metric of anatomy truncation were used to compensate for the effects of clinical image truncation. In the thorax, D(W)versus D(eff) had an R(2) of 0.51 (n = 200, 50 patients at four anatomic locations); in the abdomen and pelvis, R(2) was 0.90 (n = 150, 50 patients at three anatomic locations). By correcting for image truncation, the proportion of clinically reconstructed images with an extracted D(W) within ±5% of the maximal FOV D(W) increased from 54% to 90% in the thorax (n = 3602 images) and from 95% to 100% in the abdomen and pelvis (6181 images). The D(W) extracted from axial CT images is a reliable measure of patient size, and varying degrees of clinical image truncation can be readily corrected. Automated measurement of patient size combined with CT radiation exposure metrics may enable patient-specific dose estimation on a large scale. © RSNA, 2013.

  18. Transparent self-cleaning lubricant-infused surfaces made with large-area breath figure patterns

    Science.gov (United States)

    Zhang, Pengfei; Chen, Huawei; Zhang, Liwen; Ran, Tong; Zhang, Deyuan

    2015-11-01

    Nepenthes pitcher inspired slippery lubricant-infused porous surfaces greatly impact the understanding of liquid-repellent surfaces construction and have attracted extensive attention in recent years due to their potential applications in self-cleaning, anti-fouling, anti-icing, etc. In this work, we have successfully fabricated transparent slippery lubricant-infused surfaces based on breath figure patterns (BFPs). Large-area BFPs with interconnected pores were initially formed on the glass substrate and then a suitable lubricant was added onto the surfaces. The interconnected pores in BFPs were able to hold the lubricant liquid in place and form a stable liquid/solid composite surface capable of repelling a variety of liquids. The liquid-repellent surfaces show extremely low critical sliding angles for various liquids, thus providing the surfaces with efficient self-cleaning property. It was also found that the liquid droplets' sliding behaviors on the surfaces were significantly influenced by the tilting angle of the substrate, liquid volume, liquid chemical properties, and pore sizes of the surfaces.

  19. Carcinoma of the large bowel after a single massive dose of radiation in healthy teenagers

    Energy Technology Data Exchange (ETDEWEB)

    Rotmensch, S.; Avigad, I.; Soffer, E.E.; Horowitz, A.; Bar-Meir, S.; Confino, R.; Czerniak, A.; Wolfstein, I.

    1986-02-15

    Three healthy teenagers were exposed to a single pelvic x-ray irradiation as part of sterilization experiments performed in the Auschwitz concentration camp in 1943. Single and multiple carcinomas of the colon and rectum developed 40 years later in the radiation field. Histologic examination of surgical specimens revealed severe radiation-induced changes in all layers of tumor-adjacent areas. In contrast to previous reports of radiation-induced large bowel cancers, these women had not undergone repeated courses of radiation, had no known co-existing disease that might raise the risk for colonic and rectal malignancies, and had an extremely long and remarkably similar latency period. These cases emphasize the need for long-term surveillance in previously radiated patients. Since thousands of teenagers were subjected to similar sterilization experiments, awareness of this association might help in the early diagnosis of additional cases.

  20. Carcinoma of the large bowel after a single massive dose of radiation in healthy teenagers

    International Nuclear Information System (INIS)

    Rotmensch, S.; Avigad, I.; Soffer, E.E.; Horowitz, A.; Bar-Meir, S.; Confino, R.; Czerniak, A.; Wolfstein, I.

    1986-01-01

    Three healthy teenagers were exposed to a single pelvic x-ray irradiation as part of sterilization experiments performed in the Auschwitz concentration camp in 1943. Single and multiple carcinomas of the colon and rectum developed 40 years later in the radiation field. Histologic examination of surgical specimens revealed severe radiation-induced changes in all layers of tumor-adjacent areas. In contrast to previous reports of radiation-induced large bowel cancers, these women had not undergone repeated courses of radiation, had no known co-existing disease that might raise the risk for colonic and rectal malignancies, and had an extremely long and remarkably similar latency period. These cases emphasize the need for long-term surveillance in previously radiated patients. Since thousands of teenagers were subjected to similar sterilization experiments, awareness of this association might help in the early diagnosis of additional cases

  1. Numerical simulation of sloshing with large deforming free surface by MPS-LES method

    Science.gov (United States)

    Pan, Xu-jie; Zhang, Huai-xin; Sun, Xue-yao

    2012-12-01

    Moving particle semi-implicit (MPS) method is a fully Lagrangian particle method which can easily solve problems with violent free surface. Although it has demonstrated its advantage in ocean engineering applications, it still has some defects to be improved. In this paper, MPS method is extended to the large eddy simulation (LES) by coupling with a sub-particle-scale (SPS) turbulence model. The SPS turbulence model turns into the Reynolds stress terms in the filtered momentum equation, and the Smagorinsky model is introduced to describe the Reynolds stress terms. Although MPS method has the advantage in the simulation of the free surface flow, a lot of non-free surface particles are treated as free surface particles in the original MPS model. In this paper, we use a new free surface tracing method and the key point is "neighbor particle". In this new method, the zone around each particle is divided into eight parts, and the particle will be treated as a free surface particle as long as there are no "neighbor particles" in any two parts of the zone. As the number density parameter judging method has a high efficiency for the free surface particles tracing, we combine it with the neighbor detected method. First, we select out the particles which may be mistreated with high probabilities by using the number density parameter judging method. And then we deal with these particles with the neighbor detected method. By doing this, the new mixed free surface tracing method can reduce the mistreatment problem efficiently. The serious pressure fluctuation is an obvious defect in MPS method, and therefore an area-time average technique is used in this paper to remove the pressure fluctuation with a quite good result. With these improvements, the modified MPS-LES method is applied to simulate liquid sloshing problems with large deforming free surface. Results show that the modified MPS-LES method can simulate the large deforming free surface easily. It can not only capture

  2. Biodosimetry versus physical dosimetry for emergency dose assessment following large-scale radiological exposures

    International Nuclear Information System (INIS)

    McKeever, S.W.S.; Sholom, S.

    2016-01-01

    Existing data on intercomparisons involving biodosimetry or physical dosimetry methods are analyzed and the results interpreted regarding their efficacy in triage in emergency dosimetry following mass casualty radiological events. The biodosimetry technique examined is dicentric chromosome aberrations (DCA). The physical dosimetry techniques include electron paramagnetic resonance (EPR) of biological material (teeth) and physical material (smartphone screen glass), and optically stimulated luminescence (OSL) of electronic components (surface mount resistors) from mobile phones. Issues relating to calibration and interpretation of the data are discussed. An important conclusion of the analysis is that more research is critically needed to interpret the efficacy of the various methods. Included in this needed research are intercomparisons of the various methods in controlled experiments and the need to harmonize protocols. - Highlights: • Utility of bio- and physical dosimetry methods for emergency dosimetry triage. • Analysis of intercomparison data for different bio- and physical dosimetry methods. • The percentage of false positives and false negatives for a simulated IND event. • More research, especially intercomparisons, is required to reduce uncertainties.

  3. 3D-PTV on large particles in the free-surface vortex

    NARCIS (Netherlands)

    Duinmeijer, S.P.A.; Clemens, F.H.L.R.

    2017-01-01

    Wastewater pumping stations can experience problems due the presence of floating particles of solidified fat and grease. To transport this debris, the ability of free-surface vortices as transport mechanism is investigated. An experimental set-up is developed where the behaviour of large particles

  4. Surface and Curve Skeletonization of Large 3D Models on the GPU

    NARCIS (Netherlands)

    Jalba, Andrei C.; Kustra, Jacek; Telea, Alexandru C.

    We present a GPU-based framework for extracting surface and curve skeletons of 3D shapes represented as large polygonal meshes. We use an efficient parallel search strategy to compute point-cloud skeletons and their distance and feature transforms (FTs) with user-defined precision. We regularize

  5. Use of Large Surface MicroChannel Plates for the Tagging of Intermediate Energy Exotic Beams

    International Nuclear Information System (INIS)

    Lombardo, I.; Amorini, F.; Cardella, G.; Cavallaro, S.; De Filippo, E.; Geraci, E.; Grassi, L.; La Guidara, E.; Lanzalone, G.; Pagano, A.; Papa, M.; Pirrone, S.; Politi, G.; Porto, F.; Rizzo, F.; Russotto, P.; Verde, G.; Vigilante, M.

    2011-01-01

    We show the properties of the tagging system for exotic beams coupled to the CHIMERA detector. In particular, the characteristics of a newly developed large surface MicroChannel Plate will be discussed. Timing and efficiency of this instrument have been investigated. Preliminary results of tests performed with radioactive beams and alpha sources are presented.

  6. Dose-volume histogram and dose-surface histogram analysis for skin reactions to carbon ion radiotherapy for bone and soft tissue sarcoma.

    Science.gov (United States)

    Yanagi, Takeshi; Kamada, Tadashi; Tsuji, Hiroshi; Imai, Reiko; Serizawa, Itsuko; Tsujii, Hirohiko

    2010-04-01

    To evaluate the usefulness of the dose-volume histogram (DVH) and dose-surface histogram (DSH) as clinically relevant and available parameters that helped to identify bone and soft tissue sarcoma patients at risk of developing late skin reactions, including ulceration, when treated with carbon ion radiotherapy. Thirty-five patients with bone and soft tissue sarcoma treated with carbon ion beams were studied. The clinical skin reactions were evaluated. Some pretreatment variables were compared with the grade of late skin reactions. Average DVH and DSH were established in accordance with the grading of the skin reactions. Prescribed dose, the difference in depths between the skin surface and the proximal extent of the tumor, and some DVH/DSH parameters were correlated with late skin reaction (> or = grade 3) according to univariate analysis. Furthermore, the area irradiated with over 60 GyE (S(60)>20 cm(2)) on DSH was the most important factor by multivariate analysis. The area irradiated with over 60 GyE (S(60)>20 cm(2)) on DSH was found to be a parameter for use as a predictor of late skin reactions. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.

  7. Skin dose estimation for various beam modifiers and source-to-surface distances for 6MV photons

    Directory of Open Access Journals (Sweden)

    Yadav Girigesh

    2009-01-01

    Full Text Available The purpose of this study was to learn the skin dose estimation for various beam modifiers at various source-to-surface distances (SSDs for a 6 MV photon. Surface and buildup region doses were measured with an acrylic slab phantom and Markus 0.055 cc parallel plate (PP ionization chamber. Measurements were carried out for open fields, motorized wedge fields, acrylic block tray fields ranging from 3 x 3 cm 2 to 30 x 30 cm 2 . Twenty-five percent of the field was blocked with a cerrobend block and a Multileaf collimator (MLC. The effect of the blocks on the skin dose was measured for a 20 x 20 cm 2 field size, at 80 cm, 100 cm and 120 cm SSD. During the use of isocentric treatments, whereby the tumor is positioned at 100 cm from the source, depending on the depth of the tumor and size of the patient, the SSD can vary from 80 cm to 100 cm. To achieve a larger field size, the SSD can also be extended up to 120 cm at times. The skin dose increased as field size increased. The skin dose for the open 10 x10 cm 2 field was 15.5%, 14.8% and 15.5% at 80 cm, 100 cm and 120 cm SSDs, respectively. The skin dose due to a motorized 60 0 wedge for the 10 x 10 cm 2 field was 9.9%, 9.5%, and 9.5% at 80 cm, 100 cm and 120 cm SSDs. The skin dose due to acrylic block tray, of thickness 1.0 cm for a 10 x 10 cm 2 field was 27.0%, 17.2% and 16.1% at 80, 100 and 120 cm SSD respectively. Due to the use of an acrylic block tray, the surface dose was increased for all field sizes at the above three SSDs and the percentage skin dose was more dominant at the lower SSD and larger field size. The skin dose for a 30 x 30 cm 2 field size at 80 cm SSD was 38.3% and it was 70.4% for the open and acrylic block tray fields, respectively. The skin doses for motorized wedge fields were lower than for open fields. The effect of SSDs on the surface dose for motorized 60° wedge fields was not significant for a small field size (difference was less than 1% up to a 15 x 15 cm 2 field size

  8. Botswana water and surface energy balance research program. Part 2: Large scale moisture and passive microwaves

    Science.gov (United States)

    Vandegriend, A. A.; Owe, M.; Chang, A. T. C.

    1992-01-01

    The Botswana water and surface energy balance research program was developed to study and evaluate the integrated use of multispectral satellite remote sensing for monitoring the hydrological status of the Earth's surface. The research program consisted of two major, mutually related components: a surface energy balance modeling component, built around an extensive field campaign; and a passive microwave research component which consisted of a retrospective study of large scale moisture conditions and Nimbus scanning multichannel microwave radiometer microwave signatures. The integrated approach of both components are explained in general and activities performed within the passive microwave research component are summarized. The microwave theory is discussed taking into account: soil dielectric constant, emissivity, soil roughness effects, vegetation effects, optical depth, single scattering albedo, and wavelength effects. The study site is described. The soil moisture data and its processing are considered. The relation between observed large scale soil moisture and normalized brightness temperatures is discussed. Vegetation characteristics and inverse modeling of soil emissivity is considered.

  9. Large displacement bi-directional out-of-plane Lorentz actuator array for surface manipulation

    International Nuclear Information System (INIS)

    Park, Byoungyoul; Afsharipour, Elnaz; Chrusch, Dwayne; Shafai, Cyrus; Andersen, David; Burley, Greg

    2017-01-01

    This paper presents a large displacement out-of-plane Lorentz actuator array for surface manipulation. Actuators are formed from single crystal silicon flexible serpentine springs on either side of a rigid crossbar containing a narrow contact pillar. A rigid mounting rail system was employed to enable a 5  ×  5 array, which offers scalability of the array size. Analytical and finite element models were used to optimize actuator design. Individual actuators were tested to show linear deflection response of  ±150 µ m motion, using a  ±14.7 mA current in the presence of a 0.48 T magnetic field. This actuator array is suitable for various 2D surface modification applications due to its large deformation with low current and temperature of operation, and narrow contact area to a target surface. (paper)

  10. Seeded on-surface supramolecular growth for large area conductive donor-acceptor assembly.

    Science.gov (United States)

    Goudappagouda; Chithiravel, Sundaresan; Krishnamoorthy, Kothandam; Gosavi, Suresh W; Babu, Sukumaran Santhosh

    2015-07-04

    Charge transport features of organic semiconductor assemblies are of paramount importance. However, large-area extended supramolecular structures of donor-acceptor combinations with controlled self-assembly pathways are hardly accessible. In this context, as a representative example, seeded on-surface supramolecular growth of tetrathiafulvalene and tetracyano-p-quinodimethane (TTF-TCNQ) using active termini of solution-formed sheaves has been introduced to form an extended assembly. We demonstrate for the first time, the creation of a large-area donor-acceptor assembly on the surface, which is practically very tedious, using a seeded, evaporation-assisted growth process. The excellent molecular ordering in this assembly is substantiated by its good electrical conductivity (~10⁻² S cm⁻¹). The on-surface assembly via both internally formed and externally added sheaf-like seeds open new pathways in supramolecular chemistry and device applications.

  11. Investigation on large-area fabrication of vivid shark skin with superior surface functions

    Science.gov (United States)

    Chen, Huawei; Zhang, Xin; Ma, Lingxi; Che, Da; Zhang, Deyuan; Sudarshan, T. S.

    2014-10-01

    Shark skin has attracted worldwide attention because of its superior drag reduction, antifouling performance induced from its unique surface morphology. Although the vivid shark skin has been fabricated by a bio-replicated micro-imprinting approach in previous studies and superior drag reduction effect has been validated in water tunnel, continuous large-area fabrication is still an obstacle to wide apply. In this paper, one novel bio-replication coating technology is proposed for large-area transfer of shark skin based on rapid UV curable paint. Apart from design of coating system, bio-replication accuracy of surface morphology was validated about 97% by comparison between shark skin template and coating surface morphology. Finally, the drag reduction and anti-fouling function of coating surface were tested in water tunnel and open algae pond respectively. Drag reduction rate of coating surface was validated about 12% higher and anti-fouling was proved to about hundred times ameliorate, all of which are more excellent than simple 2D riblet surface.

  12. Specific dose-dependent damage of Lieberkuehn crypts promoted by large doses of type 2 ribosome-inactivating protein nigrin b intravenous injection to mice

    International Nuclear Information System (INIS)

    Gayoso, M.J.; Munoz, R.; Arias, Y.; Villar, R.; Rojo, M.A.; Jimenez, P.; Ferreras, J.M.; Aranguez, I.; Girbes, T.

    2005-01-01

    Nigrin b is a non-toxic type 2 ribosome-inactivating protein as active as ricin at ribosomal level but 10 5 and 5 x 10 3 times less toxic for animal cell cultures and mice, respectively, than ricin. The purpose of the present study was to analyze the effects of intravenous injection of large amounts of nigrin b to the mouse. Injection through the tail vein of 16 mg/kg body weight killed all mice studied before 2 days. Analysis of several major tissues by light microscopy did not reveal gross nigrin b-promoted changes, except in the intestines which appeared highly damaged. As a consequence of the injury, the villi and crypt structures of the small intestine disappeared, leading to profuse bleeding and death. In contrast, intravenous injection of 5 mg/kg body weight was not lethal to mice but did trigger reversible toxic effects. In both cases, lethal and sub-lethal doses, the target of nigrin b appeared to be the highly proliferating stem cells of the intestinal crypts, which had undergone apoptotic changes. In contrast to nigrin b, the injection of 3 μg/kg of ricin kills all mice in 5 days but does not trigger apoptosis in the crypts. Therefore, the effect seen with sub-lethal nigrin b concentrations seems to be specific. Nigrin b killed COLO 320 human colon adenocarcinoma cells with an IC 50 of 3.1 x 10 -8 M and the effect was parallel to the extent of DNA fragmentation of these cells. Accordingly, despite the low general toxicity exerted by nigrin b as compared with ricin, intravenous injection of large amounts of nigrin b is able to kill mouse intestinal stem cells without threatening the lives of the animals, thereby opening a door for its use for the targeting of intestinal stem cells

  13. Treatment of skin carcinomas of the face by high-dose-rate brachytherapy and custom-made surface molds

    International Nuclear Information System (INIS)

    Guix, Benjamin; Finestres, Fernando; Tello, Jose-Ignacio; Palma, Cesar; Martinez, Antonio; Guix, Jose-Ramon; Guix, Ricardo

    2000-01-01

    Purpose: To analyze the results obtained in a prospective group of patients with basal or squamous cell skin carcinomas of the face treated by high-dose-rate (HDR) brachytherapy via custom-made surface molds. Methods and Materials: A total of 136 patients with basal or squamous cell carcinomas of the face were treated between March 1992 and March 1997 by surface molds and HDR brachytherapy with iridium-192. Nineteen patients were treated with standard Brock applicators and 117 patients with custom-made polymethyl methacrylate applicators, built over a plaster mold obtained of the patient's face. Minimum dose administered to the tumor was 6000 to 6500 cGy in 33 to 36 fractions at 180 cGy/fraction in lesions of up to 4 cm. Lesions greater than 4 cm were boosted up to 7500-8000 cGy after a 3-week pause. Results: With the custom-made surface molds, the dose distribution was uniform in the surface of the skin and at 5 mm depth in the whole area of the applicator. Differences between the areas of maximum and minimum dose at this depth never reached values higher than 5% of the prescribed dose. At the edges of the custom-made molds dose gradient was sharp, with the detected dose at 5 mm from the applicator being negligible. All the patients were complete responders. There were 3 local recurrences, 1/73 patients treated for primary tumor and 2/63 patients treated for recurrent tumor. Actuarial local control at 5 years for all patients was 98%, for those patients with primary tumors 99%, and for recurrent patients 87%. The treatment tolerance was excellent in all cases. No severe, early, or late, complications were detected. Conclusions: Radiotherapy is a highly effective treatment of skin carcinomas of the face. Custom-made molds, to be used in conjunction with HDR brachytherapy equipment, make possible a uniform dose distribution, with a sharp dose gradient in the limits of applicators. Custom-made surface molds are easy and safe to use, and they fit very accurately for

  14. An evaluation of surface-dose increase caused by the thermoplastic shell in head and neck radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Wada, Shin-ichi; Hayama, Kazuhide; Toyama, Michio; Ninomiya, Shuichi; Eguchi, Toru; Takase, Hiroshi; Maeda, Kadzuo (Nippon Dental Univ., Niigata (Japan) Faculty of Dentistry (Niigata))

    1992-10-01

    Some kinds of the thermoplastic shells have been developed to improve the reproducibility of patient immobilization in head and neck radiotherapy treatment. Due to a build-up layer of high energy photons, the consideration of the surface-dose under the shell is important in radiotherapy treatment planning. This paper presents the precise evaluation of the surface-dose affected by the shell. The therapy machine used was 2.8 MV linac X-ray. The shell used was mesh sheet type thermoplastic shell. The TPR (tissue peak ratio) in the build-up layer was measured in various irradiation fields under the conditions with or without a wedge filter. The coefficients m' and K's of the power function of the build-up region were obtained from the relation between TPR and the irradiation fields. As a result, the coefficients were approximately intermediate values between cobalt-60 [gamma]-ray and 4.3 MV X-ray. When a wedge filter was used, the coefficients shifted toward those of higher energy. Before obtaining the dose distribution under the thermoplastic shell, film response was tested under the conditions of various irradiation fields and use of a wedge filter. The results showed that the film response was constant enough for dosimetry in the build-up region. Digital surface-absorbed dose distribution images under the shell were obtained using the microphotometer-microcomputer system. The digital image demonstrated a meshy dose pattern under the shell. In the area of a higher absorbed dose, the dose increases were in the range of 40-50%. The differences depended on not only the irradiation field and presence of a wedge-filter, but especially on the extent of expansion of the thermoplastic material in making the shell mask. (author).

  15. Rapid fabrication of large-area, corrosion-resistant superhydrophobic Mg alloy surfaces.

    Science.gov (United States)

    Xu, Wenji; Song, Jinlong; Sun, Jing; Lu, Yao; Yu, Ziyuan

    2011-11-01

    A superhydrophobic magnesium (Mg) alloy surface was successfully fabricated via a facile electrochemical machining process, and subsequently covered with a fluoroalkylsilane (FAS) film. The surface morphologies and chemical compositions were investigated using a scanning electron microscope (SEM) equipped with an energy-dispersive spectroscopy (EDS) and a Fourier-transform infrared spectrophotometer (FTIR). The results show hierarchal rough structures and an FAS film with a low surface energy on the Mg alloy surfaces, which confers good superhydrophobicity with a water contact angle of 165.2° and a water tilting angle of approximately 2°. The processing conditions, such as the processing time and removal rate per unit area at a constant removal mass per unit area, were investigated to determine their effects on the superhydrophobicity. Interestingly, when the removal mass per unit area is constant at approximately 11.10 mg/cm(2), the superhydrophobicity does not change with the removal rate per unit area. Therefore, a superhydrophobic Mg alloy surface can be rapidly fabricated based on this property. A large-area superhydrophobic Mg alloy surface was also fabricated for the first time using a small-area moving cathode. The corrosion resistance and durability of the superhydrophobic surfaces were also examined.

  16. Large eddies modulating flux convergence and divergence in a disturbed unstable atmospheric surface layer

    Science.gov (United States)

    Gao, Zhongming; Liu, Heping; Russell, Eric S.; Huang, Jianping; Foken, Thomas; Oncley, Steven P.

    2016-02-01

    The effects of large eddies on turbulence structures and flux transport were studied using data collected over a flat cotton field during the Energy Balance Experiment 2000 in the San Joaquin Valley of California in August 2000. Flux convergence (FC; larger fluxes at 8.7 m than 2.7 m) and divergence (FD) in latent heat flux (LE) were observed in a disturbed, unstable atmospheric surface layer, and their magnitudes largely departed from the prediction of Monin-Obukhov similarity theory. From our wavelet analysis, it was identified that large eddies affected turbulence structures, scalar distribution, and flux transport differently at 8.7 m and 2.7 m under the FC and FD conditions. Using the ensemble empirical mode decomposition, time series data were decomposed into large eddies and small-scale background turbulence, the time-domain characteristics of large eddies were examined, and the flux contribution by large eddies was also determined quantitatively. The results suggest that large eddies over the frequency range of 0.002 Hz < f < 0.02 Hz (predominantly 300-400 m) enhanced the vertical velocity spectra more significantly at 8.7 m than 2.7 m, leading to an increased magnitude of the cospectra and thus LE at 8.7 m. In the FD case, however, these large eddies were not present and even suppressed in the vertical velocity spectra at 8.7 m. Consequently, the cospectra divergence over the low-frequency ranges primarily caused the LE divergence. This work implies that large eddies may either improve or degrade the surface energy balance closure by increasing or decreasing turbulent fluxes, respectively.

  17. Nanotechnological Advances in Catalytic Thin Films for Green Large-Area Surfaces

    Directory of Open Access Journals (Sweden)

    Suzan Biran Ay

    2015-01-01

    Full Text Available Large-area catalytic thin films offer great potential for green technology applications in order to save energy, combat pollution, and reduce global warming. These films, either embedded with nanoparticles, shaped with nanostructuring techniques, hybridized with other systems, or functionalized with bionanotechnological methods, can include many different surface properties including photocatalytic, antifouling, abrasion resistant and mechanically resistive, self-cleaning, antibacterial, hydrophobic, and oleophobic features. Thus, surface functionalization with such advanced structuring methods is of significance to increase the performance and wide usage of large-area thin film coatings specifically for environmental remediation. In this review, we focus on methods to increase the efficiency of catalytic reactions in thin film and hence improve the performance in relevant applications while eliminating high cost with the purpose of widespread usage. However, we also include the most recent hybrid architectures, which have potential to make a transformational change in surface applications as soon as high quality and large area production techniques are available. Hence, we present and discuss research studies regarding both organic and inorganic methods that are used to structure thin films that have potential for large-area and eco-friendly coatings.

  18. Analysis of enhancement at small and large radiation doses for effectiveness of inactivation in cultured cells by combining two agents with radiation

    NARCIS (Netherlands)

    Franken, Nicolaas A. P.; Kok, H. Petra; Crezee, Johannes; Barendsen, Gerrit W.

    2016-01-01

    To evaluate the enhancement effect of two combined radiation-sensitizing agents in mammalian cells at small doses as compared to large doses using the linear-quadratic (LQ) mathematical model. Data on clonogenic assays concerning the radio-enhancement effects of combined halogenated pyrimidines and

  19. Beyond Massive MIMO: The Potential of Data Transmission With Large Intelligent Surfaces

    Science.gov (United States)

    Hu, Sha; Rusek, Fredrik; Edfors, Ove

    2018-05-01

    In this paper, we consider the potential of data-transmission in a system with a massive number of radiating and sensing elements, thought of as a contiguous surface of electromagnetically active material. We refer to this as a large intelligent surface (LIS). The "LIS" is a newly proposed concept, which conceptually goes beyond contemporary massive MIMO technology, that arises from our vision of a future where man-made structures are electronically active with integrated electronics and wireless communication making the entire environment "intelligent". We consider capacities of single-antenna autonomous terminals communicating to the LIS where the entire surface is used as a receiving antenna array. Under the condition that the surface-area is sufficiently large, the received signal after a matched-filtering (MF) operation can be closely approximated by a sinc-function-like intersymbol interference (ISI) channel. We analyze the capacity per square meter (m^2) deployed surface, \\hat{C}, that is achievable for a fixed transmit power per volume-unit, \\hat{P}. Moreover, we also show that the number of independent signal dimensions per m deployed surface is 2/\\lambda for one-dimensional terminal-deployment, and \\pi/\\lambda^2 per m^2 for two and three dimensional terminal-deployments. Lastly, we consider implementations of the LIS in the form of a grid of conventional antenna elements and show that, the sampling lattice that minimizes the surface-area of the LIS and simultaneously obtains one signal space dimension for every spent antenna is the hexagonal lattice. We extensively discuss the design of the state-of-the-art low-complexity channel shortening (CS) demodulator for data-transmission with the LIS.

  20. R-CHOP with dose-attenuated radiation therapy could induce good prognosis in gastric diffuse large B cell lymphoma

    Directory of Open Access Journals (Sweden)

    Mishima Yuko

    2012-09-01

    Full Text Available Abstract Background The treatment strategy for gastric diffuse large cell lymphoma (DLBCL has not been standardized in such as to the cycles of chemotherapy, dose of radiation, or necessity for the surgery. Although the results of CHOP or R-CHOP treatments have demonstrated the good prognosis, the treatments have been controversial in many cases. Methods We retrospectively analyzed 40 gastric DLBCL patients receiving chemotherapy with or without radiation in our institute. Those in stages II-IV were treated with six cycles of R-CHOP without radiation; for those in stage I, we administered three cycles of R-CHOP with radiation. Results The three-year overall survival (OS and progression-free survival (PFS rates were 95.2 and 91.8%, respectively. Those in stage I obtained 100% of OS. The radiation dose prescribed was 30.6 Gy for CR cases and 39.6 to 40 Gy for PR after chemotherapy. Although survival rates tended to correlate with staging groups or age-adjusted IPI classifications, multivariate statistical analysis did not show clear differences. All 14 patients with initial bleeding were successfully managed without surgery during treatment. Conclusion R-CHOP therapy was very effective for gastric DLBCL. It may be not necessary to use more than 30.6 Gy of radiotherapy in the highly chemo-sensitive cases. Less toxic treatments should be made available to gastric DLBCL patients.

  1. High-Accuracy Near-Surface Large-Eddy Simulation with Planar Topography

    Science.gov (United States)

    2015-08-03

    Planar Topography ” The views, opinions and/or findings contained in this report are those of the author(s) and should not contrued as an official...Simulation with Planar Topography ” Report Title Large-eddy simulation (LES) has been plagued by an inability to predict the law-of-the-wall (LOTW) in mean...Report July 2015 HIGH-ACCURACY NEAR-SURFACE LARGE-EDDY SIMULATION WITH PLANAR TOPOGRAPHY ARO Grant W911NF-04-1-0205 PI: James G. Brasseur

  2. Overcoming the reference large-area sources non-uniformity in surface area monitor calibration

    Energy Technology Data Exchange (ETDEWEB)

    Junior, Iremar Alves S.; Siqueira, Paulo de T.D.; Xavier, Marcs; Nascimento, Eduardo do; Potiens, Maria da Penha A., E-mail: iremarjr@usp.br, E-mail: ptsiquei@ipen.br, E-mail: mxavier@ipen.br, E-mail: eduardon@ufba.br, E-mail: mppalbu@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    This paper describes a study using MCNP5 simulations, a Monte Carlo based radiation transport code, in order to evaluate the possibility of using reference large-area sources that do not meet the uniformity recommendations of the ISO 8769:2010 in surface contamination monitors calibration. {sup 14}C, {sup 36}Cl, {sup 99}Tc, {sup 137}Cs and {sup 90}Sr + {sup 90}Y large area reference sources were simulated as well as the setup and the detector probe. Simulations were carried out for both uniform and non-uniform surface distributions. In the case of uniform distribution, specific weights for each region were considered, as obtained in the uniformity evaluation measurements. To each simulation, it was considered the average number of signals generated in each detector probe, i.e., it was determined the fraction of stories depositing energy in the corresponding gas filled region of the detector. Simulations results show differences in detection efficiency values up to 15%. (author)

  3. SU-F-I-47: Optimizing Protocols for Image Quality and Dose in Abdominal CT of Large Patients

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, L; Yester, M [UAB Medical Center, Birmingham, AL (United Kingdom)

    2016-06-15

    Purpose: Newer CT scanners are able to use scout views to adjust mA throughout the scan in order to achieve a given noise level. However, given constraints of radiologist preferences for kVp and rotation time, it may not be possible to achieve an acceptable noise level for large patients. A study was initiated to determine for which patients kVp and/or rotation time should be changed in order to achieve acceptable image quality. Methods: Patient scans were reviewed on two new Emergency Department scanners (Philips iCT) to identify patients over a large range of sizes. These iCTs were set with a limit of 500 mA to safeguard against a failure that might cause a CT scan to be (incorrectly) obtained at too-high mA. Scout views of these scans were assessed for both AP and LAT patient width and AP and LAT standard deviation in an ROI over the liver. Effective diameter and product of the scout standard deviations over the liver were both studied as possible metrics for identifying patients who would need kVp and/or rotation time changed. The mA used for the liver in the CT was compared to these metrics for those patients whose CT scans showed acceptable image quality. Results: Both effective diameter and product of the scout standard deviations over the liver result in similar predictions for which patients will require the kVp and/or rotation time to be changed to achieve an optimal combination of image quality and dose. Conclusion: Two mechanisms for CT technologists to determine based on scout characteristics what kVp, mA limit, and rotation time to use when DoseRight with our physicians’ preferred kVp and rotation time will not yield adequate image quality are described.

  4. Design and calibration of a scanning tunneling microscope for large machined surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Grigg, D.A.; Russell, P.E.; Dow, T.A.

    1988-12-01

    During the last year the large sample STM has been designed, built and used for the observation of several different samples. Calibration of the scanner for prope dimensional interpretation of surface features has been a chief concern, as well as corrections for non-linear effects such as hysteresis during scans. Several procedures used in calibration and correction of piezoelectric scanners used in the laboratorys STMs are described.

  5. Novel threadlike structures may be present on the large animal organ surface: evidence in Swine model.

    Science.gov (United States)

    Bae, Kyoung-Hee; Park, Sang Hyun; Lee, Byung-Cheon; Nam, Min-Ho; Yoon, Ji Woong; Kwon, Hee-Min; Yoon, Seung Zhoo

    2013-01-01

    Background. The types of embryonic development probably provoke different paths of novel threadlike structure (NTS) development. The authors hypothesized that NTS may be easily observed on the surface of swine intestines by using trypan blue staining method and visualization under an optical microscope. Methods. General anesthesia was administered to 2 Yorkshire pigs. The abdominal walls of the pigs were carefully dissected along the medial alba. NTSs were identified on organ surfaces under a stereoscopic microscope after trypan blue staining. Isolated NTS specimens obtained from the large intestine were subjected to 4',6-diamidino-2-phenylindole (DAPI) staining and observed using the polarized light microscopy to confirm whether the obtained structure fits the definition of NTS. Results. We found elastic, semitransparent threadlike structures (forming a network structure) that had a milky-white color in situ and in vivo in swine large intestines. The samples showed distinct extinction of polarized light at every 90 degrees, and nucleus was shown to be rod shaped by DAPI staining, indicating that they meet the criteria of NTS. Conclusion. We used a swine model to demonstrate that NTS may be present on large animal organ surfaces. Our results may permit similar studies by using human specimens.

  6. Novel Threadlike Structures May Be Present on the Large Animal Organ Surface: Evidence in Swine Model

    Directory of Open Access Journals (Sweden)

    Kyoung-Hee Bae

    2013-01-01

    Full Text Available Background. The types of embryonic development probably provoke different paths of novel threadlike structure (NTS development. The authors hypothesized that NTS may be easily observed on the surface of swine intestines by using trypan blue staining method and visualization under an optical microscope. Methods. General anesthesia was administered to 2 Yorkshire pigs. The abdominal walls of the pigs were carefully dissected along the medial alba. NTSs were identified on organ surfaces under a stereoscopic microscope after trypan blue staining. Isolated NTS specimens obtained from the large intestine were subjected to 4′,6-diamidino-2-phenylindole (DAPI staining and observed using the polarized light microscopy to confirm whether the obtained structure fits the definition of NTS. Results. We found elastic, semitransparent threadlike structures (forming a network structure that had a milky-white color in situ and in vivo in swine large intestines. The samples showed distinct extinction of polarized light at every 90 degrees, and nucleus was shown to be rod shaped by DAPI staining, indicating that they meet the criteria of NTS. Conclusion. We used a swine model to demonstrate that NTS may be present on large animal organ surfaces. Our results may permit similar studies by using human specimens.

  7. SU-E-J-87: Lung Deformable Image Registration Using Surface Mesh Deformation for Dose Distribution Combination

    International Nuclear Information System (INIS)

    Labine, A; Carrier, J; Bedwani, S; Chav, R; DeGuise, J

    2014-01-01

    Purpose: To allow a reliable deformable image registration (DIR) method for dose calculation in radiation therapy. This work proposes a performance assessment of a morphological segmentation algorithm that generates a deformation field from lung surface displacements with 4DCT datasets. Methods: From the 4DCT scans of 15 selected patients, the deep exhale phase of the breathing cycle is identified as the reference scan. Varian TPS EclipseTM is used to draw lung contours, which are given as input to the morphological segmentation algorithm. Voxelized contours are smoothed by a Gaussian filter and then transformed into a surface mesh representation. Such mesh is adapted by rigid and elastic deformations to match each subsequent lung volumes. The segmentation efficiency is assessed by comparing the segmented lung contour and the TPS contour considering two volume metrics, defined as Volumetric Overlap Error (VOE) [%] and Relative Volume Difference (RVD) [%] and three surface metrics, defined as Average Symmetric Surface Distance (ASSD) [mm], Root Mean Square Symmetric Surface Distance (RMSSD) [mm] and Maximum Symmetric Surface Distance (MSSD) [mm]. Then, the surface deformation between two breathing phases is determined by the displacement of corresponding vertices in each deformed surface. The lung surface deformation is linearly propagated in the lung volume to generate 3D deformation fields for each breathing phase. Results: The metrics were averaged over the 15 patients and calculated with the same segmentation parameters. The volume metrics obtained are a VOE of 5.2% and a RVD of 2.6%. The surface metrics computed are an ASSD of 0.5 mm, a RMSSD of 0.8 mm and a MSSD of 6.9 mm. Conclusion: This study shows that the morphological segmentation algorithm can provide an automatic method to capture an organ motion from 4DCT scans and translate it into a volume deformation grid needed by DIR method for dose distribution combination

  8. Investigation on the growth of DAST crystals of large surface area for THz applications

    International Nuclear Information System (INIS)

    Vijay, R. Jerald; Melikechi, N.; Thomas, Tina; Gunaseelan, R.; Arockiaraj, M. Antony; Sagayaraj, P.

    2012-01-01

    Graphical abstract: It is evident from the photographs that the crystal tend to grow as a needle (Fig. 1a) in the lower concentration region (2–3 g/200 mL); whereas, in the high concentration region (5 g/200 mL) though there is a marked enlargement in the size of the crystal, the morphology of the resulting DAST crystal is slightly irregular (Fig. 1d) in nature. Among the four concentrations employed, best result was obtained with the DAST–methanol solution of concentration 4 g/200 mL; which resulted in the DAST crystal of large surface area (270 mm 2 ) with high transparency and nearly square shape (Fig. 1c) in a growth period of 20–25 days. Highlights: ► DAST crystals of different sizes are obtained for different concentrations. ► The main focus is to grow DAST crystals with large surface area. ► Structural, optical, thermal and mechanical properties are investigated. - Abstract: The growth of high quality 4-N,N-dimethylamino-4-N-methyl-stilbazoliumtosylate (DAST) crystal with large surface area is reported by adopting the slope nucleation coupled slow evaporation method (SNM-SE). The structure and composition of the crystal are studied by single crystal X-ray diffraction and CHN analyses. The linear optical properties are investigated by UV–vis absorption. The melting point and thermal behavior of DAST are investigated using differential scanning calorimetric (DSC) and thermogravimetric analyses (TGA). The Vickers microhardness number (VHN) and work hardening coefficient of the grown crystal have been determined. The surface features of the DAST crystal are analyzed by scanning electron microscopy (SEM) and it confirmed the presence of narrow line defects (NLDs) in the sample.

  9. Development of mathematical model for estimation of entrance surface dose in mammography

    International Nuclear Information System (INIS)

    Abdelgani, Yassir Mohammed Tahir

    2013-05-01

    Computer simulation is a convenient and frequently used tool in the study of x-ray mammography, for the design of novel detector systems, the evaluation of dose deposition, x-ray technique optimization, and other applications. An important component in the simulation process is the accurate computer generation of x-ray spectra. A computer model for the generation of x-ray spectra in the mammographic energy rang from 18 keV to 40 ke V has been developed by Boone et al. Due to the lack of QC and dose measurement tools, in addition to unavailability of medical physics, a mathematical tool was developed for estimation of patient exposure and entrance dose. The proposed model require no assumptions concerning the physics of x-ray production in an x-ray tube, but rather makes use of x-ray spectra recently measured experimentally by John M Boone (Department of Radiology, University of California). Using experimental dose measurements for specific tube voltage and tube current the generated x-ray spectra were calibrated. The spectrum calibration factors show a tube voltage dependency. From the calibrated x-ray spectrum, the exposure and entrance dose were estimated for different k Vp and m A. Results show good agreement between the measured and estimated values for tube voltage between 18 to 45 k Vp with a good correlation of nearly 1 and equal slope. The maximum estimated different between the measured and the simulated dose is approximately equal to 0.07%.(Author)

  10. Advances in deployable structures and surfaces for large apertures in space

    Science.gov (United States)

    Santiago-Prowald, J.; Baier, H.

    2013-12-01

    Large apertures in space have applications for telecommunications, Earth observation and scientific missions. This paper reviews advances in mechanical architectures and technologies for large deployable apertures for space antennas and telescopes. Two complementary approaches are described to address this challenge: the deployment of structures based on quasi-rigid members and highly flexible structures. Regarding the first approach, deployable articulated structures are classified in terms of their kinematics as 3D or planar linkages in multiple variants, resulting in different architectures of radial, peripheral or modular constructions. A dedicated discussion on the number of degrees of freedom and constraints addresses the deployment reliability and thermo-elastic stability of large elastic structures in the presence of thermal gradients. This aspect has been identified as a design driver for new developments of peripheral ring and modular structures. Meanwhile, other design drivers are maintained, such as the optimization of mass and stiffness, overall accuracy and stability, and pragmatic aspects including controlled industrial development and a commitment to operators' needs. Furthermore, reflecting surface technologies and concepts are addressed with a view to the future, presenting advances in technical solutions for increasing apertures and reducing areal mass densities to affordable levels for future missions. Highly flexible materials capable of producing ultra-stable shells are described with reference to the state of the art and new developments. These concepts may enable large deployable surfaces for antennas and telescopes, as well as innovative optical concepts such as photon sieves. Shape adjustment and shape control of these surfaces are described in terms of available technologies and future needs, particularly for the reconfiguration of telecommunications antennas. In summary, the two complementary approaches described and reviewed cover the

  11. Surface accuracy of a large-scale compact antenna test range considering mechanism, metrology and alignment

    International Nuclear Information System (INIS)

    Zhou, Guofeng; Li, Xiaoxing; Li, Dongsheng; Luan, Jingdong; Zhao, Jinze

    2014-01-01

    A large compact range (CR) having a width of 23 m and height of 16 m that will generate a Φ15 m quiet zone is presented. The antenna consists of 30 blocks and 76 serrated reflectors. Its mechanical accuracy is reflected in two aspects: surface precision and gap precision. In addition, the root-mean-square (RMS) surface accuracy should be less than or equal to 0.075 mm for achieving the highest operating frequency of 40 GHz, and the gaps between two segments should be controlled strictly to the tolerance of 0.4 ± 0.2 mm for avoiding gap diffraction and compensating for inter-block interference due to thermal deformation. The surface accuracy in terms of mechanical structure, metrology and alignment approach is very tight. First, a high-accuracy honeycomb sandwich panel, anisotropic back structure and spatial parallel adjustment mechanism are introduced, and the error contributions of these three mechanisms are 0.03 mm, 0.01 mm and 0.005 mm, respectively. Second, a measurement network based on laser tracker metrology was established, and the RMS error of the measurement system is controlled to 0.025 mm through the optimization of the measuring stations and weighted coordinate regression. Third, an original alignment approach that divides the entire assembly into three key phases by marked point edge-constrained surface is proposed. By performing a few iterations of onsite adjustment, the reflectors were aligned in the prescribed positions, and the gap quality was controlled effectively. Finally, the on-site alignment of the large CR is introduced. The final antenna surface RMS accuracy was up to 0.054 mm, and the gaps achieved the desired design index. (paper)

  12. The Dose Assessment in the Vault Test Case of Near-Surface Disposal Facility for Drinking Water Scenario

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hyoung; Choi, Byung Seon; Moon, Jei Kwon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Park, Jae Woo [Jeju National University, Jeju (Korea, Republic of)

    2012-05-15

    It is generally accepted that the radionuclides contained in the radioactive wastes will be eventually released and these will be transported to the accessible environment (near-field, far-field, biosphere). Therefore, the long-term safety assessment of near-surface radioactive waste disposal should be required by modeling the expected release of radionuclides from the repository, far-field area, and biosphere. Finally, the effective dose rate should be estimated through the released radionuclides. In this study, the radiological dose was evaluated for the reference near-surface radioactive waste disposal facility in Vaalputs, South Africa, which has been selected as a part of IAEA coordinated research program on improvement of safety assessment methodologies(ISAM). The assessment of radiological dose was performed for drinking water scenario from a well. The release and transport of radionuclides in disposal system were simulated by GoldSim. This approach suggested the time variation of effective dose over long-term period. And the results from this approach were compared with another approach method for the same facility and scenario

  13. The Dose Assessment in the Vault Test Case of Near-Surface Disposal Facility for Drinking Water Scenario

    International Nuclear Information System (INIS)

    Kim, Tae Hyoung; Choi, Byung Seon; Moon, Jei Kwon; Park, Jae Woo

    2012-01-01

    It is generally accepted that the radionuclides contained in the radioactive wastes will be eventually released and these will be transported to the accessible environment (near-field, far-field, biosphere). Therefore, the long-term safety assessment of near-surface radioactive waste disposal should be required by modeling the expected release of radionuclides from the repository, far-field area, and biosphere. Finally, the effective dose rate should be estimated through the released radionuclides. In this study, the radiological dose was evaluated for the reference near-surface radioactive waste disposal facility in Vaalputs, South Africa, which has been selected as a part of IAEA coordinated research program on improvement of safety assessment methodologies(ISAM). The assessment of radiological dose was performed for drinking water scenario from a well. The release and transport of radionuclides in disposal system were simulated by GoldSim. This approach suggested the time variation of effective dose over long-term period. And the results from this approach were compared with another approach method for the same facility and scenario

  14. A smart car for the surface shape measurement of large antenna based on laser tracker

    Science.gov (United States)

    Gu, Yonggang; Hu, Jing; Jin, Yi; Zhai, Chao

    2012-09-01

    The geometric accuracy of the surface shape of large antenna is an important indicator of antenna’s quality. Currently, high-precision measurement of large antenna surface shape can be performed in two ways: photogrammetry and laser tracker. Photogrammetry is a rapid method, but its accuracy is not enough good. Laser tracker can achieve high precision, but it is very inconvenient to move the reflector (target mirror) on the surface of the antenna by hand during the measurement. So, a smart car is designed to carry the reflector in this paper. The car, controlled by wireless, has a small weight and a strong ability for climbing, and there is a holding bracket gripping the reflector and controlling reflector rise up and drop down on the car. During the measurement of laser tracker, the laser beam between laser tracker and the reflector must not be interrupted, so two high-precision three-dimensional miniature electronic compasses, which can real-time monitor the relative angle between the holding bracket and the laser tracker’s head, are both equipped on the car and the head of laser tracker to achieve automatic alignment between reflector and laser beam. With the aid of the smart car, the measurement of laser tracker has the advantages of high precision and rapidity.

  15. Puddle jumping: Spontaneous ejection of large liquid droplets from hydrophobic surfaces during drop tower tests

    Science.gov (United States)

    Attari, B.; Weislogel, M.; Wollman, A.; Chen, Y.; Snyder, T.

    2016-10-01

    Large droplets and puddles jump spontaneously from sufficiently hydrophobic surfaces during routine drop tower tests. The simple low-cost passive mechanism can in turn be used as an experimental device to investigate dynamic droplet phenomena for drops up to 104 times larger than their normal terrestrial counterparts. We provide and/or confirm quick and qualitative design guides for such "drop shooters" as employed in drop tower tests including relationships to predict droplet ejection durations and velocities as functions of drop volume, surface texture, surface contour, wettability pattern, and fluid properties including contact angle. The latter is determined via profile image comparisons with numerical equilibrium interface computations. Water drop volumes of 0.04-400 ml at ejection speeds of -0.007-0.12 m/s are demonstrated herein. A sample application of the drop jump method is made to the classic problem of low-gravity phase change heat transfer for large impinging drops. Many other candidate problems might be identified by the reader.

  16. Measurement of Entrance Surface Dose on an Anthropomorphic Thorax Phantom Using a Miniature Fiber-Optic Dosimeter

    OpenAIRE

    Yoo, Wook Jae; Shin, Sang Hun; Jeon, Dayeong; Hong, Seunghan; Sim, Hyeok In; Kim, Seon Geun; Jang, Kyoung Won; Cho, Seunghyun; Youn, Won Sik; Lee, Bongsoo

    2014-01-01

    A miniature fiber-optic dosimeter (FOD) system was fabricated using a plastic scintillating fiber, a plastic optical fiber, and a multi-pixel photon counter to measure real-time entrance surface dose (ESD) during radiation diagnosis. Under varying exposure parameters of a digital radiography (DR) system, we measured the scintillating light related to the ESD using the sensing probe of the FOD, which was placed at the center of the beam field on an anthropomorphic thorax phantom. Also, we obt...

  17. Development of a scintillating fiber-optic dosimeter for measuring the entrance surface dose in diagnostic radiology

    International Nuclear Information System (INIS)

    Yoo, Wook Jae; Jeon, Dayeong; Seo, Jeong Ki; Shin, Sang Hun; Han, Ki-Tek; Youn, Won Sik; Cho, Seunghyun; Lee, Bongsoo

    2013-01-01

    As a direct method, a scintillating fiber-optic dosimeter (SFOD) was fabricated using an organic scintillator, a plastic optical fiber, and a photomultiplier tube (PMT) to measure entrance surface doses (ESDs) in diagnostic radiology. In this study, we measured the scintillating lights, which are altered by to the exposure parameters, such as the tube potential, current-time product, and focus-surface distance (FSD), with an SFOD placed on the top of an acrylic and aluminum chest phantom to provide a backscatter medium. The scintillating light signals of the SFOD were compared with the ESDs obtained using conventional dosimeters. The ESDs that were measured using the dose-area product (DAP) meter, as an indirect method, and a semiconductor dosimeter, as a direct method, were distinguished according to differences in the measurement position and the method used. In the case of the two direct methods with the SFOD and the semiconductor dosimeter, the output light signals of the SFOD were similar to the ESDs of the semiconductor dosimeter. It is expected that the SFOD will be a useful dosimeter for diagnostic radiology due to its many advantages, including its small size, lightweight, substantial flexibility, remote sensing, real-time monitoring, and immunity to electromagnetic interference (EMI). - Highlights: ► Fabrication of a scintillating fiber-optic dosimeter for use in diagnostic radiology. ► Measurements of the scintillating light according to the exposure parameters. ► Comparison of the entrance surface doses obtained using conventional dosimeters

  18. Staff eye doses in a large medical centre in Saudi Arabia: are they meeting the new ICRP recommendations?

    International Nuclear Information System (INIS)

    Al-Haj, Abdalla N.; Al-Gain, Ibrahim; Lobriguito, Aida M.

    2015-01-01

    A 5-y retrospective analysis of the cardiology staff eye doses was performed on 34 staff from different categories (cardiologists, nurses and technologists) at King Faisal Specialist Hospital and Research Centre (KFSHRC) in Riyadh, Saudi Arabia. KFSHRC is a tertiary medical centre with 800-bed capacity having more than 5000 cardiac catheterisation procedures performed annually. The aim of the study is to derive staff doses to the lens of the eyes using the personal dose equivalent Hp(0.07) values from the annual TLD dose report for the years 2008-2012 and determine the category of staff with high estimated eye doses. The study also aims to investigate the causes for high doses and recommend dose-reduction techniques. The dose to the lens of the eye was estimated by using the ratio Hp(0.07) slab /H lens of 1.1 where Hp(0.07) values are the reported doses read from TLD badge worn at the collar level. The average annual eye dose of each category for the 5-y monitoring period was determined. Cardiologists tend to receive higher doses than the nurses by a factor of 2-4 and can exceed 5 mSv y -1 . No correlation exists between the eye doses of nurses and the cardiologists. There is a need to use a conversion coefficient in terms of eye lens dose per dose-area product for faster estimation of eye lens doses. However, there is a limitation on the use of the conversion coefficient because it will depend on the clinical procedure and the X-ray tube angulation. Further investigation on this limitation is needed. (authors)

  19. Large-eddy simulation of open channel flow with surface cooling

    International Nuclear Information System (INIS)

    Walker, R.; Tejada-Martínez, A.E.; Martinat, G.; Grosch, C.E.

    2014-01-01

    Highlights: • Open channel flow comparable to a shallow tidal ocean flow is simulated using LES. • Unstable stratification is imposed by a constant surface cooling flux. • Full-depth, convection-driven, rotating supercells develop when cooling is applied. • Strengthening of cells occurs corresponding to an increasing of the Rayleigh number. - Abstract: Results are presented from large-eddy simulations of an unstably stratified open channel flow, driven by a uniform pressure gradient and with zero surface shear stress and a no-slip lower boundary. The unstable stratification is applied by a constant cooling flux at the surface and an adiabatic bottom wall, with a constant source term present to ensure the temperature reaches a statistically steady state. The structure of the turbulence and the turbulence statistics are analyzed with respect to the Rayleigh number (Ra τ ) representative of the surface buoyancy relative to shear. The impact of the surface cooling-induced buoyancy on mean and root mean square of velocity and temperature, budgets of turbulent kinetic energy (and components), Reynolds shear stress and vertical turbulent heat flux will be investigated. Additionally, colormaps of velocity fluctuations will aid the visualization of turbulent structures on both vertical and horizontal planes in the flow. Under neutrally stratified conditions the flow is characterized by weak, full-depth, streamwise cells similar to but less coherent than Couette cells in plane Couette flow. Increased Ra τ and thus increased buoyancy effects due to surface cooling lead to full-depth convection cells of significantly greater spanwise size and coherence, thus termed convective supercells. Full-depth convective cell structures of this magnitude are seen for the first time in this open channel domain, and may have important implications for turbulence analysis in a comparable tidally-driven ocean boundary layer. As such, these results motivate further study of the

  20. Image-based Exploration of Iso-surfaces for Large Multi- Variable Datasets using Parameter Space.

    KAUST Repository

    Binyahib, Roba S.

    2013-05-13

    With an increase in processing power, more complex simulations have resulted in larger data size, with higher resolution and more variables. Many techniques have been developed to help the user to visualize and analyze data from such simulations. However, dealing with a large amount of multivariate data is challenging, time- consuming and often requires high-end clusters. Consequently, novel visualization techniques are needed to explore such data. Many users would like to visually explore their data and change certain visual aspects without the need to use special clusters or having to load a large amount of data. This is the idea behind explorable images (EI). Explorable images are a novel approach that provides limited interactive visualization without the need to re-render from the original data [40]. In this work, the concept of EI has been used to create a workflow that deals with explorable iso-surfaces for scalar fields in a multivariate, time-varying dataset. As a pre-processing step, a set of iso-values for each scalar field is inferred and extracted from a user-assisted sampling technique in time-parameter space. These iso-values are then used to generate iso- surfaces that are then pre-rendered (from a fixed viewpoint) along with additional buffers (i.e. normals, depth, values of other fields, etc.) to provide a compressed representation of iso-surfaces in the dataset. We present a tool that at run-time allows the user to interactively browse and calculate a combination of iso-surfaces superimposed on each other. The result is the same as calculating multiple iso- surfaces from the original data but without the memory and processing overhead. Our tool also allows the user to change the (scalar) values superimposed on each of the surfaces, modify their color map, and interactively re-light the surfaces. We demonstrate the effectiveness of our approach over a multi-terabyte combustion dataset. We also illustrate the efficiency and accuracy of our

  1. Surfacing safety hazards using standardized operating room briefings and debriefings at a large regional medical center.

    Science.gov (United States)

    Bandari, Jathin; Schumacher, Kathy; Simon, Michelle; Cameron, Danielle; Goeschel, Christine A; Holzmueller, Christine G; Makary, Martin A; Welsh, Robert J; Berenholtz, Sean M

    2012-04-01

    Briefings and debriefings, previously shown to be a practical and feasible strategy to improve interdisciplinary communication and teamwork in the operating room (OR), was then assessed as a strategy to prospectively surface clinical and operational defects in surgical care--and thereby prevent patient harm. A one-page, double-sided briefing and debriefing tool was used by surgical teams during cases at the William Beaumont Hospital Royal Oak (Royal Oak, Michigan) campus to surface clinical and operational defects during the study period (October 2006-May 2010). Defects were coded into six categories (with each category stratified by briefing or debriefing period) during the first six months, and refinement of coding resulted in expansion to 16 defect categories and no further stratification. A provider survey was used in January 2008 to interview a sample of 40 caregivers regarding the perceived effectiveness of the tool in surfacing defects. The teams identified a total of 6,202 defects--an average of 141 defects per month--during the entire study period. Of 2,760 defects identified during the six-defect coding period, 1,265 (46%) surfaced during briefings, and the remaining 1,495 (54%) during debriefings. Equipment (48%) and communication (31%) issues were most prominent. Of 3,442 defects identified during the 16-defect coding period, the most common were Central Processing Department (CPD) instrumentation (22%) and Communication/Safety (15%). Overall, 70 (87%) of the 80 responses were in agreement that briefings were effective for surfacing defects, as were 59 (76%) of the 78 responses for debriefings. Briefings and debriefings were a practical and effective strategy to surface potential surgical defects in the operating rooms of a large medical center.

  2. Sensitivity of coefficients for converting entrance surface dose and kerma-area product to effective dose and energy imparted to the patient

    International Nuclear Information System (INIS)

    Wise, K.N.; Sandborg, M.; Persliden, J.; Alm Carlsson, G.

    1999-01-01

    We investigate the sensitivity of the conversions from entrance surface dose (ESD) or kerma-area product (KAP) to effective dose (E) or to energy imparted to the patient (ε) to the likely variations in tube potential, field size, patient size and sex which occur in clinical work. As part of a factorial design study for chest and lumbar spine examinations, the tube potentials were varied to be ±10% of the typical values for the examinations while field sizes and the positions of the field centres were varied to be representative of values drawn from measurements on patient images. Variation over sex and patient size was based on anthropomorphic phantoms representing males and females of ages 15 years (small adult) and 21 years (reference adult). All the conversion coefficients were estimated using a mathematical phantom programmed with the Monte Carlo code EGS4 for all factor combinations and analysed statistically to derive factor effects. In general, the factors studied behaved independently in the sense that interaction of the physical factors generally gave no more than a 5% variation in a conversion coefficient. Taken together, variation of patient size, sex, field size and field position can lead to significant variation of E/KAP by up to a factor of 2, of E/ESD by up to a factor of 3, of ε/KAP by a factor of 1.3 and of ε/ESD by up to a factor of 2. While KAP is preferred to determine ε, the results show no strong preference of KAP over ESD in determining E. The mean absorbed dose D-bar in the patient obtained by dividing ε (determined using KAP) by the patient's mass was found to be the most robust measure of E. (author)

  3. Fluvial and climate controls on the surface energy balance in a large lowland river

    Science.gov (United States)

    Bray, E. N.; Dunne, T.; Dozier, J.

    2013-12-01

    Partitioning of radiant and turbulent energy into evaporation and absorption in a river channel is controlled by climate and streamflow characteristics, and controls the water and energy balance. Atmosphere-surface interactions, coupled with advective processes, drive the heterogeneity of heat storage and exchange over longitudinal profiles whose hydraulic and thermal patterns are crucial for survival of migratory and resident fishes and subject to alteration by humans. Over 100 large-scale flow experiments have been conducted globally to measure abiotic and biotic responses to streamflow, yet none has been utilized to elucidate large-scale physical controls on the surface energy balance of a river. In this paper, we describe a synoptic method by which net solar radiation and turbulent heat fluxes were calculated over the length of a river from time series of hydroclimatological and fluvial conditions measured during a long-term large-scale flow experiment. We examine what are the dominant physical controls to the surface energy balance in a lowland river when surface water stage varies with flow releases in a 240-km reach of the San Joaquin River, California, USA. We developed an energy balance model integrated with advective exchange of heat utilizing spatially-distributed predictions of water surface elevation, inundated surface area, and velocity from an existing hydraulic model that accounts for losses and gains over the length of the river. Absorption of radiation along the river is determined by the wavelength-dependent index of refraction, expressed by the angle of refraction and the optical depth as a function of physical depth and the absorption coefficient. Results show that over the solar spectrum, the absorption coefficient varies by seven orders of magnitude, while flow depth varies by two orders of magnitude over time and distance. Observations and modeling show that (1) discharge is controlled mainly by flow releases, diversions, and exchanges with

  4. Groundwater-surface water interactions in a large semi-arid floodplain: implications for salinity management

    Science.gov (United States)

    Lamontagne, Sébastien; Leaney, Fred W.; Herczeg, Andrew L.

    2005-10-01

    Flow regulation and water diversion for irrigation have considerably impacted the exchange of surface water between the Murray River and its floodplains. However, the way in which river regulation has impacted groundwater-surface water interactions is not completely understood, especially in regards to the salinization and accompanying vegetation dieback currently occurring in many of the floodplains. Groundwater-surface water interactions were studied over a 2 year period in the riparian area of a large floodplain (Hattah-Kulkyne, Victoria) using a combination of piezometric surface monitoring and environmental tracers (Cl-, 2H, and 18O). Despite being located in a local and regional groundwater discharge zone, the Murray River is a losing stream under low flow conditions at Hattah-Kulkyne. The discharge zone for local groundwater, regional groundwater and bank recharge is in the floodplain within 1 km of the river and is probably driven by high rates of transpiration by the riparian Eucalyptus camaldulensis woodland. Environmental tracers data suggest that the origin of groundwater is principally bank recharge in the riparian zone and a combination of diffuse rainfall recharge and localized floodwater recharge elsewhere in the floodplain. Although the Murray River was losing under low flows, bank discharge occurred during some flood recession periods. The way in which the water table responded to changes in river level was a function of the type of stream bank present, with point bars providing a better connection to the alluvial aquifer than the more common clay-lined banks. Understanding the spatial variability in the hydraulic connection with the river channel and in vertical recharge following inundations will be critical to design effective salinity remediation strategies for large semi-arid floodplains.

  5. A new optical method for measuring surface temperature at large incident probe angles

    Science.gov (United States)

    Lee, A. S.; Norris, P. M.

    1997-02-01

    A novel thermoreflectance technique has been developed for noncontact temperature measurements using laser light incident at large angles on solid materials and devices. The method involves measuring the differential reflectance from a polarization modulated laser beam. The polarization differential reflectance technique is demonstrated on single-crystal Si wafers and on a polycrystalline carbon thin film over a temperature range of 20-60 °C. The method is shown to be an extremely sensitive temperature probe for near grazing angle measurements, which could be useful for monitoring the surface temperature of closely stacked silicon wafers used in batch processing in the microelectronics industry.

  6. A novel hybrid surface micromachined segmented mirror for large aperture laser applications

    Science.gov (United States)

    Li, Jie; Chen, Haiqing; Yu, Hongbin

    2006-07-01

    A novel hybrid surface micromachined segmented mirror array is described. This device is capable of scaling to large apertures for correcting time-varying aberrations in laser applications. Each mirror is composed of bottom electrode, support part, and mirror plate, in which a T-shaped beam structure is used to support the mirror plate. It can provide mirror with vertical movement and rotation around two horizontal axes. The test results show that the maximum deflection along the vertical direction of the mirror plate is 2 microns, while the rotation angles around x and y axes are +-2.3 deg. and +-1.45 deg., respectively.

  7. Compact Wideband and Low-Profile Antenna Mountable on Large Metallic Surfaces

    DEFF Research Database (Denmark)

    Zhang, Shuai; Pedersen, Gert F.

    2017-01-01

    This paper proposes a compact wideband and low-profile antenna mountable on large metallic surfaces. Six rows of coupled microstrip resonators with different lengths are printed on a Teflon block. The lengths of the microstrip resonators in different rows are gradually reduced along the end...... resonance at the lowest frequency. A trapezoid-shaped capacitive-feed (C-fed) strip is utilized and also printed on the Teflon block to globally optimize the wideband impedance matching. The proposed antenna covers a relative bandwidth of 109% for VSWR

  8. Fabrication of large-area hydrophobic surfaces with femtosecond-laser-structured molds

    Science.gov (United States)

    Wu, P. H.; Cheng, C. W.; Chang, C. P.; Wu, T. M.; Wang, J. K.

    2011-11-01

    Fast replication of large-area femtosecond-laser-induced surface micro/nanostructures on plastic parts by injection molding is demonstrated. An STAVAX steel mold insert is irradiated by femtosecond laser pulses with linear or circular polarization to form periodic-like nanostructures or nanostructure-covered conical microstructures. It was then used for the process of thermal injection molding. The process provides high-volume manufacturing means to generate hydrophobic enhanced plastic parts, which is expected to be widely used in consumables and chemical/biomedical device industries.

  9. Strong relationship between DMS and the solar radiation dose over the global surface ocean.

    Science.gov (United States)

    Vallina, Sergio M; Simó, Rafel

    2007-01-26

    Marine biogenic dimethylsulfide (DMS) is the main natural source of tropospheric sulfur, which may play a key role in cloud formation and albedo over the remote ocean. Through a global data analysis, we found that DMS concentrations are highly positively correlated with the solar radiation dose in the upper mixed layer of the open ocean, irrespective of latitude, plankton biomass, or temperature. This is a necessary condition for the feasibility of a negative feedback in which light-attenuating DMS emissions are in turn driven by the light dose received by the pelagic ecosystem.

  10. Surface States Effect on the Large Photoluminescence Redshift in GaN Nanostructures

    KAUST Repository

    Ben Slimane, Ahmed

    2013-01-01

    We report on the large photoluminescence redshift observed in nanostructures fabricated using n-type GaN by ultraviolet (UV) metal-assisted electroless chemical-etching method. The scanning electron microscopy (SEM) characterization showed nanostructures with size dispersion ranging from 10 to 100 nm. We observed the crystalline structure using high resolution transmission electron microscopy (HRTEM) and electron energy loss (EELS) techniques. In contrast to 362 nm UV emission from the GaN epitaxy, the nanostructures emitted violet visible-light in photoluminescence (PL) characterization with increasing optical excitation. An energy band model was presented to shed light on the large PL redshift under the influence of surface states, which resulted in two competing photoluminescence mechanisms depending on excitation conditions.

  11. Observation of Stable Low Surface Resistance in Large-Grain Niobium SRF Cavities

    Energy Technology Data Exchange (ETDEWEB)

    Geng, Rongli [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States); Huang, Shichun [Institute of Modern Physics (IMP)/Chinese Academy of Sciences (CAS), Lanzhou (China)

    2016-05-01

    Low surface resistance, or high unloaded quality factor (Q0), superconducting radio frequency (SRF) cavities are being pursued actively nowadays as their application in large-scale CW SRF accelerators can save capital and operational cost in cryogenics. There are different options in realization of such cavities. One of them is the large-grain (LG) niobium cavity. In this contribution, we present new experimental results in evaluation of LG niobium cavities cooled down in the presence of an external magnetic field. High Q0 values are achieved even with an ambient magnetic field of up to 100 mG. More over, it is observed that these high Q0 values are super-robust against repeated quench, literally not affected at all after the cavity being deliberately quenched for hundreds of times in the presence of an ambient magnetic field of up to 200 mG.

  12. A method for producing uniform dose distributions in the junction regions of large hinge angle electrol fields

    International Nuclear Information System (INIS)

    Zavgorodni, S.F.; Beckham, W.A.; Roos, D.E.

    1996-01-01

    The planning problems presented by abutting electron fields are well recognised. Junctioning electron fields with large hinge angle compounds the problems because of the creation of closely situated 'hot' and 'cold' spots. The technique involving a compensated superficial x-ray (SXR) field to treat the junction region between electron fields was developed and used in a particular clinical case (treatment of a squamous cell carcinoma of the forehead/scalp). The SXR beam parameters were chosen and the compensator was designed to make the SXR field complementary to the electron fields. Application of a compensated SXR field eliminated 'cold' spots in the junction region and minimised 'hot' spots to (110%). In the clinical case discusses the 'hot' spots due to the SXR field would not appear because of increased attenuation of the soft x-rays in bone. The technique proposed produces uniform dose distribution up to 3 cm deep and can be considered as an additional tool for dealing with electron fields junctioning problems. (author)

  13. Large Differences between Glaciers 3D Surface Extents and 2D Planar Areas in Central Tianshan

    Directory of Open Access Journals (Sweden)

    Xianwei Wang

    2017-04-01

    Full Text Available Most glaciers in China lie in high mountainous environments and have relatively large surface slopes. Common analyses consider glaciers’ projected areas (2D Area in a two-dimensional plane, which are much smaller than glacier’s topographic surface extents (3D Area. The areal difference between 2D planar areas and 3D surface extents exceeds −5% when the glacier’s surface slope is larger than 18°. In this study, we establish a 3D model in the Muzart Glacier catchment using ASTER GDEM data. This model is used to quantify the areal difference between glaciers’ 2D planar areas and their 3D surface extents in various slope zones and elevation bands by using the second Chinese Glacier Inventory (CGI2. Finally, we analyze the 2D and 3D area shrinking rate between 2007 and 2013 in Central Tianshan using glaciers derived from Landsat images by an object-based classification approach. This approach shows an accuracy of 89% when it validates by comparison of glaciers derived from Landsat and high spatial resolution GeoEye images. The extracted glaciers in 2007 also have an agreement of 89% with CGI2 data in the Muzart Glacier catchment. The glaciers’ 3D area is 34.2% larger than their 2D area from CGI2 in the Muzart Glacier catchment and by 27.9% in the entire Central Tianshan. Most underestimation occurs in the elevation bands of 4000–5000 m above sea level (a.s.l.. The 3D glacier areas reduced by 30 and 115 km2 between 2007 and 2013 in the Muzart Glacier catchment and Central Tianshan, being 37.0% and 27.6% larger than their 2D areas reduction, respectively. The shrinking rates decrease with elevation increase.

  14. Evaluation of dose to skin surface contamination in the factory Juzbado of fuel elements

    International Nuclear Information System (INIS)

    Ortiz Trujillo, D.; Agustin Perez Fonseca, A.; Alejandro Fuentes, A.

    2013-01-01

    The aim of this work is previously set a simple calculation methodology applicable to the boundary conditions surrounding the environment where skin contamination may have occurred so that you can evaluate in a simple and fast way the dose that the worker is receiving while enduring such pollution. (Author)

  15. Test-retest reliability of trunk motor variability measured by large-array surface electromyography.

    Science.gov (United States)

    Abboud, Jacques; Nougarou, François; Loranger, Michel; Descarreaux, Martin

    2015-01-01

    The objective of this study was to evaluate the test-retest reliability of the trunk muscle activity distribution in asymptomatic participants during muscle fatigue using large-array surface electromyography (EMG). Trunk muscle activity distribution was evaluated twice, with 3 to 4 days between them, in 27 asymptomatic volunteers using large-array surface EMG. Motor variability, assessed with 2 different variables (the centroid coordinates of the root mean square map and the dispersion variable), was evaluated during a low back muscle fatigue task. Test-retest reliability of muscle activity distribution was obtained using Pearson correlation coefficients. A shift in the distribution of EMG amplitude toward the lateral-caudal region of the lumbar erector spinae induced by muscle fatigue was observed. Moderate to very strong correlations were found between both sessions in the last 3 phases of the fatigue task for both motor variability variables, whereas weak to moderate correlations were found in the first phases of the fatigue task only for the dispersion variable. These findings show that, in asymptomatic participants, patterns of EMG activity are less reliable in initial stages of muscle fatigue, whereas later stages are characterized by highly reliable patterns of EMG activity. Copyright © 2015 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.

  16. Modeling large-scale human alteration of land surface hydrology and climate

    Science.gov (United States)

    Pokhrel, Yadu N.; Felfelani, Farshid; Shin, Sanghoon; Yamada, Tomohito J.; Satoh, Yusuke

    2017-12-01

    Rapidly expanding human activities have profoundly affected various biophysical and biogeochemical processes of the Earth system over a broad range of scales, and freshwater systems are now amongst the most extensively altered ecosystems. In this study, we examine the human-induced changes in land surface water and energy balances and the associated climate impacts using a coupled hydrological-climate model framework which also simulates the impacts of human activities on the water cycle. We present three sets of analyses using the results from two model versions—one with and the other without considering human activities; both versions are run in offline and coupled mode resulting in a series of four experiments in total. First, we examine climate and human-induced changes in regional water balance focusing on the widely debated issue of the desiccation of the Aral Sea in central Asia. Then, we discuss the changes in surface temperature as a result of changes in land surface energy balance due to irrigation over global and regional scales. Finally, we examine the global and regional climate impacts of increased atmospheric water vapor content due to irrigation. Results indicate that the direct anthropogenic alteration of river flow in the Aral Sea basin resulted in the loss of 510 km3 of water during the latter half of the twentieth century which explains about half of the total loss of water from the sea. Results of irrigation-induced changes in surface energy balance suggest a significant surface cooling of up to 3.3 K over 1° grids in highly irrigated areas but a negligible change in land surface temperature when averaged over sufficiently large global regions. Results from the coupled model indicate a substantial change in 2 m air temperature and outgoing longwave radiation due to irrigation, highlighting the non-local (regional and global) implications of irrigation. These results provide important insights on the direct human alteration of land surface

  17. Validity of the formalism of calculation in surface TG-43 brachytherapy high dose rate

    International Nuclear Information System (INIS)

    Granero, D.; Perez-Calatayud, J.; Vijande, J.; Ballester, F.; Rivard, M. J.

    2013-01-01

    The purpose of this work is to evaluate the clinical implications and limitations in implant surface with a source of HDR very close or in contact with the surface of the skin, also studied the effect of bolus on the implant. The two available radionuclides have been studied commercially in HDR, Ir-192 and Co-60 units. (Author)

  18. Quantifying the Impact of Immediate Reconstruction in Postmastectomy Radiation: A Large, Dose-Volume Histogram-Based Analysis

    International Nuclear Information System (INIS)

    Ohri, Nisha; Cordeiro, Peter G.; Keam, Jennifer; Ballangrud, Ase; Shi Weiji; Zhang Zhigang; Nerbun, Claire T.; Woch, Katherine M.; Stein, Nicholas F.; Zhou Ying; McCormick, Beryl; Powell, Simon N.; Ho, Alice Y.

    2012-01-01

    Purpose: To assess the impact of immediate breast reconstruction on postmastectomy radiation (PMRT) using dose-volume histogram (DVH) data. Methods and Materials: Two hundred forty-seven women underwent PMRT at our center, 196 with implant reconstruction and 51 without reconstruction. Patients with reconstruction were treated with tangential photons, and patients without reconstruction were treated with en-face electron fields and customized bolus. Twenty percent of patients received internal mammary node (IMN) treatment. The DVH data were compared between groups. Ipsilateral lung parameters included V20 (% volume receiving 20 Gy), V40 (% volume receiving 40 Gy), mean dose, and maximum dose. Heart parameters included V25 (% volume receiving 25 Gy), mean dose, and maximum dose. IMN coverage was assessed when applicable. Chest wall coverage was assessed in patients with reconstruction. Propensity-matched analysis adjusted for potential confounders of laterality and IMN treatment. Results: Reconstruction was associated with lower lung V20, mean dose, and maximum dose compared with no reconstruction (all P 98%). IMN coverage was superior in patients with reconstruction (D95 >92.0 vs 75.7%, P .05). Among IMN-treated patients, only lower lung V20 in those without reconstruction persisted (P=.022), and mean and maximum heart doses were higher than in patients without reconstruction (P=.006, P=.015, respectively). Conclusions: Implant reconstruction does not compromise the technical quality of PMRT when the IMNs are untreated. Treatment technique, not reconstruction, is the primary determinant of target coverage and normal tissue doses.

  19. Role of low-order rational surfaces in transport barrier formation on the Large Helical Device

    International Nuclear Information System (INIS)

    Toi, K.; Tanaka, K.; Watanabe, F.

    2010-11-01

    In the Large Helical Device, edge transport barrier (ETB) was formed by H-mode transition near the low-order rational surfaces, that is, at the ι/2π=1 resonant layer (ι/2π: the rotational transform) in outward-shifted plasmas of R ax =3.9m (R ax : the magnetic axis position in the vacuum field), and the ι/2π=2 resonant layer in inward-shifted plasmas of R ax =3.6m. The ι/2π=1 and 2 resonant layers reside in the stochastic field region existing just outside the last closed magnetic surface (LCFS). In the outward-shifted plasmas, H-modes without edge localized modes (ELM-free H-modes) followed by giant ELMs were obtained, while H-modes with high frequency and low amplitude ELMs were obtained in the inward-shifted plasmas. A new type of barrier formation induced by TAE bursts was observed in the plasmas of R ax =3.6m, where the transport barrier is formed near the ι/2π=1 surface locates inside LCFS. (author)

  20. Beyond Massive MIMO: The Potential of Positioning With Large Intelligent Surfaces

    Science.gov (United States)

    Hu, Sha; Rusek, Fredrik; Edfors, Ove

    2018-04-01

    We consider the potential for positioning with a system where antenna arrays are deployed as a large intelligent surface (LIS), which is a newly proposed concept beyond massive-MIMO where future man-made structures are electronically active with integrated electronics and wireless communication making the entire environment \\lq\\lq{}intelligent\\rq\\rq{}. In a first step, we derive Fisher-information and Cram\\'{e}r-Rao lower bounds (CRLBs) in closed-form for positioning a terminal located perpendicular to the center of the LIS, whose location we refer to as being on the central perpendicular line (CPL) of the LIS. For a terminal that is not on the CPL, closed-form expressions of the Fisher-information and CRLB seem out of reach, and we alternatively find approximations of them which are shown to be accurate. Under mild conditions, we show that the CRLB for all three Cartesian dimensions ($x$, $y$ and $z$) decreases quadratically in the surface-area of the LIS, except for a terminal exactly on the CPL where the CRLB for the $z$-dimension (distance from the LIS) decreases linearly in the same. In a second step, we analyze the CRLB for positioning when there is an unknown phase $\\varphi$ presented in the analog circuits of the LIS. We then show that the CRLBs are dramatically increased for all three dimensions but decrease in the third-order of the surface-area. Moreover, with an infinitely large LIS the CRLB for the $z$-dimension with an unknown $\\varphi$ is 6 dB higher than the case without phase uncertainty, and the CRLB for estimating $\\varphi$ converges to a constant that is independent of the wavelength $\\lambda$. At last, we extensively discuss the impact of centralized and distributed deployments of LIS, and show that a distributed deployment of LIS can enlarge the coverage for terminal-positioning and improve the overall positioning performance.

  1. Differences in rates of decrease of environmental radiation dose rates by ground surface property in Fukushima City after the Fukushima Daiichi nuclear power plant accident.

    Science.gov (United States)

    Kakamu, Takeyasu; Kanda, Hideyuki; Tsuji, Masayoshi; Kobayashi, Daisuke; Miyake, Masao; Hayakawa, Takehito; Katsuda, Shin-ichiro; Mori, Yayoi; Okouchi, Toshiyasu; Hazama, Akihiro; Fukushima, Tetsuhito

    2013-01-01

    After the Great East Japan Earthquake on 11 March 2011, the environmental radiation dose in Fukushima City increased. On 11 April, 1 mo after the earthquake, the environmental radiation dose rate at various surfaces in the same area differed greatly by surface property. Environmental radiation measurements continue in order to determine the estimated time to 50% reduction in environmental radiation dose rates by surface property in order to make suggestions for decontamination in Fukushima. The measurements were carried out from 11 April to 11 November 2011. Forty-eight (48) measurement points were selected, including four kinds of ground surface properties: grass (13), soil (5), artificial turf (7), and asphalt (23). Environmental radiation dose rate was measured at heights of 100 cm above the ground surface. Time to 50% reduction of environmental radiation dose rates was estimated for each ground surface property. Radiation dose rates on 11 November had decreased significantly compared with those on 11 April for all surface properties. Artificial turf showed the longest time to 50% reduction (544.32 d, standard error: 96.86), and soil showed the shortest (213.20 d, standard error: 35.88). The authors found the environmental radiation dose rate on artificial materials to have a longer 50% reduction time than that on natural materials. These results contribute to determining an order of priority for decontamination after nuclear disasters.

  2. Simulations of absorbed dose on the phantom surface of MATROSHKA-R experiment at the ISS

    Czech Academy of Sciences Publication Activity Database

    Kolísková, Zlata; Sihver, L.; Ambrožová, Iva; Sato, T.; Spurný, František; Shurshakov, V. A.

    2012-01-01

    Roč. 49, č. 2 (2012), s. 230-236 ISSN 0273-1177 R&D Projects: GA ČR GA205/09/0171; GA AV ČR KJB100480901; GA ČR GD202/09/H086 Institutional research plan: CEZ:AV0Z10480505 Keywords : MATROSHKA-R * PHITS * Simulations * Space radiation * Dose estimation Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.183, year: 2012

  3. Fast inspection of bulk and surface defects of large aperture optics in high power lasers

    Science.gov (United States)

    Zhao, Yuan'an; Hu, Guohang; Liu, Shijie; Yi, Kui; Shao, Jianda

    2015-05-01

    Laser induced damage for nanosecond pulse duration is attributed to the existence of defects. The growth and polishing, as well as coating deposition, may induce versatile kinds of defects, including dig, scratch and inclusion. It is special important to get the information of the defects, such as size and location, which is the basis to know the origin of the defects and figures out effective techniques to eliminate it. It is quite easy to get the information of the defects with micron-level resolution, but it is time-consuming and is not suitable for fast inspection of the large aperture (hundreds of millimeters). In this work, on-the-fly image capture technique was employed to realize fast inspection of large aperture optics. A continuous green laser was employed as illumination source to enhance and enlarge the image of bulk defects. So it could detect the submicron-scale defects. A transmission microscopy with white light illumination was employed to detect the surface defect. Its field of view was about 2.8mm×1.6mm. The sample was raster scanned driving by a stepper motor through the stationary illumination laser and digital camera, and the speed to scan the sample was about 10mm/s. The results of large aperture optics proved the functions of this fast inspection technique.

  4. Quantifying the Impact of Immediate Reconstruction in Postmastectomy Radiation: A Large, Dose-Volume Histogram-Based Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ohri, Nisha [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Cordeiro, Peter G. [Department of Plastic Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Keam, Jennifer [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Ballangrud, Ase [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Shi Weiji; Zhang Zhigang [Department of Biostatistics and Epidemiology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Nerbun, Claire T.; Woch, Katherine M.; Stein, Nicholas F.; Zhou Ying [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); McCormick, Beryl; Powell, Simon N. [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Ho, Alice Y., E-mail: HoA1234@mskcc.org [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States)

    2012-10-01

    Purpose: To assess the impact of immediate breast reconstruction on postmastectomy radiation (PMRT) using dose-volume histogram (DVH) data. Methods and Materials: Two hundred forty-seven women underwent PMRT at our center, 196 with implant reconstruction and 51 without reconstruction. Patients with reconstruction were treated with tangential photons, and patients without reconstruction were treated with en-face electron fields and customized bolus. Twenty percent of patients received internal mammary node (IMN) treatment. The DVH data were compared between groups. Ipsilateral lung parameters included V20 (% volume receiving 20 Gy), V40 (% volume receiving 40 Gy), mean dose, and maximum dose. Heart parameters included V25 (% volume receiving 25 Gy), mean dose, and maximum dose. IMN coverage was assessed when applicable. Chest wall coverage was assessed in patients with reconstruction. Propensity-matched analysis adjusted for potential confounders of laterality and IMN treatment. Results: Reconstruction was associated with lower lung V20, mean dose, and maximum dose compared with no reconstruction (all P<.0001). These associations persisted on propensity-matched analysis (all P<.0001). Heart doses were similar between groups (P=NS). Ninety percent of patients with reconstruction had excellent chest wall coverage (D95 >98%). IMN coverage was superior in patients with reconstruction (D95 >92.0 vs 75.7%, P<.001). IMN treatment significantly increased lung and heart parameters in patients with reconstruction (all P<.05) but minimally affected those without reconstruction (all P>.05). Among IMN-treated patients, only lower lung V20 in those without reconstruction persisted (P=.022), and mean and maximum heart doses were higher than in patients without reconstruction (P=.006, P=.015, respectively). Conclusions: Implant reconstruction does not compromise the technical quality of PMRT when the IMNs are untreated. Treatment technique, not reconstruction, is the primary

  5. Modifying a dynamic global vegetation model for simulating large spatial scale land surface water balances

    Directory of Open Access Journals (Sweden)

    G. Tang

    2012-08-01

    Full Text Available Satellite-based data, such as vegetation type and fractional vegetation cover, are widely used in hydrologic models to prescribe the vegetation state in a study region. Dynamic global vegetation models (DGVM simulate land surface hydrology. Incorporation of satellite-based data into a DGVM may enhance a model's ability to simulate land surface hydrology by reducing the task of model parameterization and providing distributed information on land characteristics. The objectives of this study are to (i modify a DGVM for simulating land surface water balances; (ii evaluate the modified model in simulating actual evapotranspiration (ET, soil moisture, and surface runoff at regional or watershed scales; and (iii gain insight into the ability of both the original and modified model to simulate large spatial scale land surface hydrology. To achieve these objectives, we introduce the "LPJ-hydrology" (LH model which incorporates satellite-based data into the Lund-Potsdam-Jena (LPJ DGVM. To evaluate the model we ran LH using historical (1981–2006 climate data and satellite-based land covers at 2.5 arc-min grid cells for the conterminous US and for the entire world using coarser climate and land cover data. We evaluated the simulated ET, soil moisture, and surface runoff using a set of observed or simulated data at different spatial scales. Our results demonstrate that spatial patterns of LH-simulated annual ET and surface runoff are in accordance with previously published data for the US; LH-modeled monthly stream flow for 12 major rivers in the US was consistent with observed values respectively during the years 1981–2006 (R2 > 0.46, p < 0.01; Nash-Sutcliffe Coefficient > 0.52. The modeled mean annual discharges for 10 major rivers worldwide also agreed well (differences < 15% with observed values for these rivers. Compared to a degree-day method for snowmelt computation, the addition of the solar radiation effect on snowmelt

  6. A comparison of dose-response models for the parotid gland in a large group of head-and-neck cancer patients.

    Science.gov (United States)

    Houweling, Antonetta C; Philippens, Marielle E P; Dijkema, Tim; Roesink, Judith M; Terhaard, Chris H J; Schilstra, Cornelis; Ten Haken, Randall K; Eisbruch, Avraham; Raaijmakers, Cornelis P J

    2010-03-15

    The dose-response relationship of the parotid gland has been described most frequently using the Lyman-Kutcher-Burman model. However, various other normal tissue complication probability (NTCP) models exist. We evaluated in a large group of patients the value of six NTCP models that describe the parotid gland dose response 1 year after radiotherapy. A total of 347 patients with head-and-neck tumors were included in this prospective parotid gland dose-response study. The patients were treated with either conventional radiotherapy or intensity-modulated radiotherapy. Dose-volume histograms for the parotid glands were derived from three-dimensional dose calculations using computed tomography scans. Stimulated salivary flow rates were measured before and 1 year after radiotherapy. A threshold of 25% of the pretreatment flow rate was used to define a complication. The evaluated models included the Lyman-Kutcher-Burman model, the mean dose model, the relative seriality model, the critical volume model, the parallel functional subunit model, and the dose-threshold model. The goodness of fit (GOF) was determined by the deviance and a Monte Carlo hypothesis test. Ranking of the models was based on Akaike's information criterion (AIC). None of the models was rejected based on the evaluation of the GOF. The mean dose model was ranked as the best model based on the AIC. The TD(50) in these models was approximately 39 Gy. The mean dose model was preferred for describing the dose-response relationship of the parotid gland. Copyright 2010 Elsevier Inc. All rights reserved.

  7. Cloud-enabled large-scale land surface model simulations with the NASA Land Information System

    Science.gov (United States)

    Duffy, D.; Vaughan, G.; Clark, M. P.; Peters-Lidard, C. D.; Nijssen, B.; Nearing, G. S.; Rheingrover, S.; Kumar, S.; Geiger, J. V.

    2017-12-01

    Developed by the Hydrological Sciences Laboratory at NASA Goddard Space Flight Center (GSFC), the Land Information System (LIS) is a high-performance software framework for terrestrial hydrology modeling and data assimilation. LIS provides the ability to integrate satellite and ground-based observational products and advanced modeling algorithms to extract land surface states and fluxes. Through a partnership with the National Center for Atmospheric Research (NCAR) and the University of Washington, the LIS model is currently being extended to include the Structure for Unifying Multiple Modeling Alternatives (SUMMA). With the addition of SUMMA in LIS, meaningful simulations containing a large multi-model ensemble will be enabled and can provide advanced probabilistic continental-domain modeling capabilities at spatial scales relevant for water managers. The resulting LIS/SUMMA application framework is difficult for non-experts to install due to the large amount of dependencies on specific versions of operating systems, libraries, and compilers. This has created a significant barrier to entry for domain scientists that are interested in using the software on their own systems or in the cloud. In addition, the requirement to support multiple run time environments across the LIS community has created a significant burden on the NASA team. To overcome these challenges, LIS/SUMMA has been deployed using Linux containers, which allows for an entire software package along with all dependences to be installed within a working runtime environment, and Kubernetes, which orchestrates the deployment of a cluster of containers. Within a cloud environment, users can now easily create a cluster of virtual machines and run large-scale LIS/SUMMA simulations. Installations that have taken weeks and months can now be performed in minutes of time. This presentation will discuss the steps required to create a cloud-enabled large-scale simulation, present examples of its use, and

  8. Changes in entrance surface dose in relation to the location of shielding material in chest computed tomography

    Science.gov (United States)

    Kang, Y. M.; Cho, J. H.; Kim, S. C.

    2015-07-01

    This study examined the effects of entrance surface dose (ESD) on the abdomen and pelvis of the patient when undergoing chest computed tomography (CT) procedure, and evaluated the effects of ESD reduction depending on the location of radiation shield. For CT scanner, the 64-slice multi-detector computed tomography was used. The alderson radiation therapy phantom and optically stimulated luminescence dosimeter (OSLD), which enabled measurement from low to high dose, were also used. For measurement of radiation dose, the slice number from 9 to 21 of the phantom was set as the test range, which included apex up to both costophrenic angles. A total of 10 OSLD nanoDots were attached for measurement of the front and rear ESD. Cyclic tests were performed using the low-dose chest CT and high-resolution CT (HRCT) protocol on the following set-ups: without shielding; shielding only on the front side; shielding only on the rear side; and shielding for both front and rear sides. According to the test results, ESD for both front and rear sides was higher in HRCT than low-dose CT when radiation shielding was not used. It was also determined that, compared to the set-up that did not use the radiation shield, locating the radiation shield on the front side was effective in reducing front ESD, while locating the radiation shield on the rear side reduced rear ESD level. Shielding both the front and rear sides resulted in ESD reduction. In conclusion, it was confirmed that shielding the front and rear sides was the most effective method to reduce the ESD effect caused by scatter ray during radiography.

  9. SU-F-I-73: Surface Dose from KV Diagnostic Beams From An On-Board Imager On a Linac Machine Using Different Imaging Techniques and Filters

    Energy Technology Data Exchange (ETDEWEB)

    Ali, I; Hossain, S; Syzek, E; Ahmad, S [University of Oklahoma Health Sciences Center, Department of Radiation Oncology, Oklahoma City, OK (United States)

    2016-06-15

    Purpose: To quantitatively investigate the surface dose deposited in patients imaged with a kV on-board-imager mounted on a radiotherapy machine using different clinical imaging techniques and filters. Methods: A high sensitivity photon diode is used to measure the surface dose on central-axis and at an off-axis-point which is mounted on the top of a phantom setup. The dose is measured for different imaging techniques that include: AP-Pelvis, AP-Head, AP-Abdomen, AP-Thorax, and Extremity. The dose measurements from these imaging techniques are combined with various filtering techniques that include: no-filter (open-field), half-fan bowtie (HF), full-fan bowtie (FF) and Cu-plate filters. The relative surface dose for different imaging and filtering techniques is evaluated quantiatively by the ratio of the dose relative to the Cu-plate filter. Results: The lowest surface dose is deposited with the Cu-plate filter. The highest surface dose deposited results from open fields without filter and it is nearly a factor of 8–30 larger than the corresponding imaging technique with the Cu-plate filter. The AP-Abdomen technique delivers the largest surface dose that is nearly 2.7 times larger than the AP-Head technique. The smallest surface dose is obtained from the Extremity imaging technique. Imaging with bowtie filters decreases the surface dose by nearly 33% in comparison with the open field. The surface doses deposited with the HF or FF-bowtie filters are within few percentages. Image-quality of the radiographic images obtained from the different filtering techniques is similar because the Cu-plate eliminates low-energy photons. The HF- and FF-bowtie filters generate intensity-gradients in the radiographs which affects image-quality in the different imaging technique. Conclusion: Surface dose from kV-imaging decreases significantly with the Cu-plate and bowtie-filters compared to imaging without filters using open-field beams. The use of Cu-plate filter does not affect

  10. Dose of dialysis based on body surface area is markedly less in younger children than in older adolescents.

    Science.gov (United States)

    Daugirdas, John T; Hanna, Melisha G; Becker-Cohen, Rachel; Langman, Craig B

    2010-05-01

    BACKGROUND AND OBSERVATIONS: The current denominator for dosing dialysis is the urea distribution volume (V). Normalizing Kt/V to body surface area (S) has been proposed, but the implications of doing this in children have not been examined. Dialysis dose given to children and adolescents was calculated in terms of conventional V-based scaling and surface-area-normalized standard Kt/V (SAN-stdKt/V) calculated as stdKt/V x (Vant/S)/17.5, where Vant was an anthropometric estimate of V calculated using the Morgenstern equation. Formal 2-pool modeling was used to compute all dialysis adequacy outputs. In 34 children (11 girls, 23 boys) dialyzed 3 times a week, age range 1.4 to 18 years, the mean delivered equilibrated Kt/V (eKt/V) was 1.40, and the mean stdKt/V was 2.49, both of which tended to be higher in younger children. The ratio of Vant to S was 15.6 +/- 2.69 and was strongly associated with age between ages 2 and 16. SAN-stdKt/V averaged 2.21 and was strongly correlated with age between ages 2 and 16. If one considers a desired target for SAN-stdKt/V to be 2.45, all children less than 10 years of age were below target, despite having relatively high values of eKt/V and stdKt/V. If a surface-area-based denominator were to be adopted for dialysis dosing, most children under 10 years of age would receive markedly less dialysis than adolescent patients and would require 6- to 8-hour hemodialysis sessions or, for the youngest children, treatments given more frequently than 3 times/wk.

  11. Surface-assisted large-scale ordering of DNA origami tiles.

    Science.gov (United States)

    Aghebat Rafat, Ali; Pirzer, Tobias; Scheible, Max B; Kostina, Anna; Simmel, Friedrich C

    2014-07-14

    The arrangement of DNA-based nanostructures into extended higher order assemblies is an important step towards their utilization as functional molecular materials. We herein demonstrate that by electrostatically controlling the adhesion and mobility of DNA origami structures on mica surfaces by the simple addition of monovalent cations, large ordered 2D arrays of origami tiles can be generated. The lattices can be formed either by close-packing of symmetric, non-interacting DNA origami structures, or by utilizing blunt-end stacking interactions between the origami units. The resulting crystalline lattices can be readily utilized as templates for the ordered arrangement of proteins. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Particularities of surface plasmon-exciton strong coupling with large Rabi splitting

    International Nuclear Information System (INIS)

    Symonds, C; Bonnand, C; Plenet, J C; Brehier, A; Parashkov, R; Lauret, J S; Deleporte, E; Bellessa, J

    2008-01-01

    This paper presents some of the particularities of the strong coupling regime occurring between surface plasmon (SP) modes and excitons. Two different active materials were deposited on a silver film: a cyanine dye J-aggregate, and a two-dimensional layered perovskite-type semiconductor. The dispersion relations, which are deduced from angular resolved reflectometry spectra, present an anticrossing characteristic of the strong coupling regime. The wavevector is a good parameter to determine the Rabi splitting. Due to the large interaction energies (several hundreds of milli-electron-volts), the calculations at constant angle can induce an overestimation of the Rabi splitting of more than a factor of two. Another property of polaritons based on SP is their nonradiative character. In order to observe the polaritonic emission, it is thus necessary to use particular extraction setups, such as gratings or prisms. Otherwise only the incoherent emission can be detected, very similar to the bare exciton emission

  13. Derivation and representation of dose-volume response from large clinical trial data sets: an example from the RADAR prostate radiotherapy trial

    Science.gov (United States)

    Ebert, M. A.; Foo, K.; Haworth, A.; Gulliford, S. L.; Kearvall, R.; Kennedy, A.; Richardson, S.; Krawiec, M.; Stewart, N.; Joseph, D. J.; Denham, J. W.

    2014-03-01

    Large multicentre radiotherapy trials incorporating assessment of multiple outcomes at multiple timepoints can generate extensive datasets. We have investigated graphical techniques for presentation of this data and the associated underlying dose-volume response information, necessary for guiding statistical analyses and translating outcomes to future patient treatments. A relational database was used to archive reviewed plan data for patients accrued to the TROG 03.04 RADAR trial. Viewing software was used to clean and enhance the data. Scripts were developed to export arbitrary dose-histogram data which was combined with clinical toxicity data with a median follow-up of 72 months. Graphical representations of dose-volume response developed include prevalence atlasing, univariate logistic regression and dose-volume-point odds ratios, and continuous cut-point derivation via ROC analysis. These representations indicate variable association of toxicities across structures and time-points.

  14. Large apparent electric size of solid-state nanopores due to spatially extended surface conduction.

    Science.gov (United States)

    Lee, Choongyeop; Joly, Laurent; Siria, Alessandro; Biance, Anne-Laure; Fulcrand, Rémy; Bocquet, Lydéric

    2012-08-08

    Ion transport through nanopores drilled in thin membranes is central to numerous applications, including biosensing and ion selective membranes. This paper reports experiments, numerical calculations, and theoretical predictions demonstrating an unexpectedly large ionic conduction in solid-state nanopores, taking its origin in anomalous entrance effects. In contrast to naive expectations based on analogies with electric circuits, the surface conductance inside the nanopore is shown to perturb the three-dimensional electric current streamlines far outside the nanopore in order to meet charge conservation at the pore entrance. This unexpected contribution to the ionic conductance can be interpreted in terms of an apparent electric size of the solid-state nanopore, which is much larger than its geometric counterpart whenever the number of charges carried by the nanopore surface exceeds its bulk counterpart. This apparent electric size, which can reach hundreds of nanometers, can have a major impact on the electrical detection of translocation events through nanopores, as well as for ionic transport in biological nanopores.

  15. The experimental study of the optimized kVp and it's relationships with the surface dose of phantom and the phantom thickness

    International Nuclear Information System (INIS)

    He Yinghui; Han Yuedong; Gao Kai; Deng Houjun; Sun Lijun; Mu Xuanxin; Ren Dongqing

    2006-01-01

    Objective: To investigate the relationships of X-ray tube voltage (kVp) with surface dose of the phantom and phantom-thickness on the basis of the particular signal to noise ratio of X-ray images. Methods X-ray digital subtraction angiography was simulated using a phantom made of acrylic acids. Under the particular surface dose of X-ray image intensifier, the curve of the surface doses of phantom surface-kVp and the curve of the phantom thickness-kVp were acquired with different exposure combinations of kVp and mAs. Results: According to the curve of the surface dose of phantom-kVp, it suggestsd that the gradual increase in kVp corresponded to the gradually decreased surface dose of phantom, with the slope tending to zero. However, the gradual increased phantom thickness corresponded to the gradually increased kVp on the basis of the curve of the phantom thickness-kVp, with the presentation of kVp = 64 + 0.89D (phantom thickness, cm) between the phantom thickness and kVp. Conclusion: The graduall increased in kVp might result in the gradual decrease in surface dose of phantom, the optimized kVp relating directly to the phantom thickness. (authors)

  16. An approach for rapid establishment of patient effective dose during radiology and results for two large university hospitals

    NARCIS (Netherlands)

    Kamman, RL; Geleijns, J; Berting, R; van der Brink, HA

    2000-01-01

    Patient dosimetry and assessment of effective dose was implemented under the condition that measurements involve commonly available instrumentation. Four categories of examination were distinguished: radiographs with manual techniques, radiographs with automatic exposure control (AEC), examinations

  17. Dose patterns in commercially insured subjects chronically exposed to opioids: a large cohort study in the United States

    Directory of Open Access Journals (Sweden)

    Boston Raymond

    2010-06-01

    Full Text Available Abstract Background Little data exist on how opioid doses vary with the length of exposure among chronic opioid users. Methods To characterize the change in the dosage of opioids over time, a retrospective cohort study using the PharMetrics database for the years 1999 through 2008 was conducted. Individuals exposed to opioids in 2000 who had 2 opioid dispensings at least 6 months apart and were opioid naive (did not receive any opioid 6 month before their exposure in 2000 were included. The date of the first dispensing in 2000 was defined as the index date and the dispensing had to be for a strong and full agonist opioid. All opioid doses were converted to oral morphine equivalent doses. Exposure was classified as continuous or intermittent. Mean, median, interquartile range, and 95th percentile of opioid dose over 6-month periods, as well as the percentage of subjects who ever received a high or very high opioid dose, were calculated. Results Among the 48,986 subjects, the mean age was 44.5 years and 54.5% were women. Intermittent exposure was observed in 99% of subjects; continuous exposure was observed in 1% of subjects. The mean duration of exposure for the subjects who were continuously exposed to opioids was 477 days. In subjects with no cancer diagnosis who were continuously exposed to opioids, the mean, 25th, 50th, and 75th percentile of dose was stable during the first 2 years of use, but the 95th percentile increased. Seven percent of them were exposed to doses of 180 mg or more of morphine at some point. Conclusions Dose escalation is uncommon in subjects with intermittent exposure to opioids. For subjects with continuous exposure to opioids who have cancer, doses rise substantially with time. For those without cancer, doses remain relatively stable for the first 2 years of use, but subsequently increase. Seven percent of subjects with no cancer diagnosis will be exposed to daily doses of 180 mg or more of morphine equivalent at some

  18. Factors contributing to high levothyroxine doses in primary hypothyroidism: an interventional audit of a large community database.

    Science.gov (United States)

    Robertson, Hannah M A; Narayanaswamy, Anil K P; Pereira, Olivia; Copland, Shirley A; Herriot, Richard; McKinlay, Alistair W; Bevan, John S; Abraham, Prakash

    2014-12-01

    While few hypothyroid patients require more than the expected weight-related dose of levothyroxine, the underlying causes of larger-than-expected dosing requirements have not been studied in a single cohort. Our aim was to determine and quantify the multiple factors contributing to high-dose levothyroxine requirements in a cohort of patients with hypothyroidism. The Grampian Automated Follow-Up Register (GAFUR) monitors around 17,500 hypothyroid patients. In 2008, 190 (1%) patients took >225 μg of levothyroxine daily. A questionnaire was sent to 174 patients (16 were untraceable) to assess causes and to offer blood tests for endomysial, parietal cell (PCA), and thyroid peroxidase (TPO) autoantibodies. Primary care practices were contacted for medication details. All patients with positive endomysial autoantibodies were referred to a gastroenterologist. Thyroid function tests and levothyroxine doses were re-evaluated in 2011. A total of 125 questionnaires (72%) were returned. Mean levothyroxine dose was 248 μg daily. Twenty-six patients (20.8%) took medication known to interfere with levothyroxine absorption, and 21 patients (16.8%) admitted to compliance issues. Seven patients had positive anti-endomysial antibodies on initial screening, with four being new diagnoses of celiac disease, and PCA were positive in 27 (21.6%) patients. At follow-up in 2011, the mean levothyroxine dose had decreased in patients on interfering medications and in the four new cases of celiac disease. Causes of patients needing high-dose levothyroxine replacement include poor compliance, medication interference, PCA (as a marker of atrophic/autoimmune gastritis), and celiac disease. Doses can be decreased following advice regarding medication or after management of underlying conditions.

  19. Screen-film versus full-field digital mammography: Radiation dose and image quality in a large teaching hospital

    Directory of Open Access Journals (Sweden)

    Stantić Tomislav J.

    2013-01-01

    Full Text Available The objective of this paper is to measure the radiation dose and image quality in conventional screen-film mammography and full-field digital mammography in women referred to mammography examination. Participants underwent bilateral, two-view screen-film mammography or full-field digital mammography. The visibility of anatomical regions and overall clinical image quality was rated by experienced radiologists. Total of 387 women and 1548 mammograms were enrolled in the study. Image quality was assessed in terms of image quality score, whereas patient dose assessment was performed in terms of mean glandular dose. Average mean glandular dose for cranio-caudal projection was 1.5 mGy and 2.1 mGy in full-field digital mammography and screen-film mammography, respectively. For medio-lateral oblique projection, corresponding values were 2.3 and 2.1 mGy. Overall image quality criteria scoring was 0.82 and 0.99 for screen-film and digital systems, respectively. The scores were in the range from 0.11 to 1.0 for different anatomical structures. Overall, full-field digital mammography was superior both in terms of image quality and dose over the screen-film mammography. The results have indicated that phantom dose values can assist in setting the optimisation activities in mammography and for comparison between mammography units. To obtain accurate diagnostic information with an acceptable radiation dose to breast, it is necessary to periodically perform patient dose and image quality surveys in all mammography units.

  20. A COMPARISON OF DOSE-RESPONSE MODELS FOR THE PAROTID GLAND IN A LARGE GROUP OF HEAD-AND-NECK CANCER PATIENTS

    NARCIS (Netherlands)

    Houweling, Antonetta C.; Philippens, Marielle E. P.; Dijkema, Tim; Roesink, Judith M.; Terhaard, Chris H. J.; Schilstra, Cornelis; Ten Haken, Randall K.; Eisbruch, Avraham; Raaijmakers, Cornelis P. J.

    2010-01-01

    Purpose: The dose response relationship of the parotid gland has been described most frequently using the Lyman-Kutcher-Burman model. However, various other normal tissue complication probability (NTCP) models exist. We evaluated in a large group of patients the value of six NTCP models that

  1. Mating competitiveness of male Anopheles arabiensis mosquitoes irradiated with a partially or fully sterilizing dose in small and large laboratory cages.

    Science.gov (United States)

    Helinski, M E H; Knols, B G J

    2008-07-01

    Male mating competitiveness is a crucial parameter in many genetic control programs including the sterile insect technique (SIT). We evaluated competitiveness of male Anopheles arabiensis Patton as a function of three experimental variables: (1) small or large cages for mating, (2) the effects of either a partially sterilizing (70 Gy) or fully sterilizing (120 Gy) dose, and (3) pupal or adult irradiation. Irradiated males competed for females with an equal number of unirradiated males. Competitiveness was determined by measuring hatch rates of individually laid egg batches. In small cages, pupal irradiation with the high dose resulted in the lowest competitiveness, whereas adult irradiation with the low dose gave the highest, with the latter males being equal in competitiveness to unirradiated males. In the large cage, reduced competitiveness of males irradiated in the pupal stage was more pronounced compared with the small cage; the males irradiated as adults at both doses performed similarly to unirradiated males. Unexpectedly, males irradiated with the high dose performed better in a large cage than in a small one. A high proportion of intermediate hatch rates was observed for eggs collected in the large cage experiments with males irradiated at the pupal stage. It is concluded that irradiation of adult An. arabiensis with the partially sterilizing dose results in the highest competitiveness for both cage designs. Cage size affected competitiveness for some treatments; therefore, competitiveness determined in laboratory experiments must be confirmed by releases into simulated field conditions. The protocols described are readily transferable to evaluate male competitiveness for other genetic control techniques.

  2. OMI/Aura Surface UVB Irradiance and Erythemal Dose Daily L2 Global 0.25 deg Lat/Lon Grid V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The Version 003 of Aura-OMI Spectral Surface UVB Irradiance and Erythemal Dose Level-2G data product (Daily level-2 data binned into global 0.25 deg Lat/Lon grids)...

  3. Evaluation of entrance surface-skin doses in animals submitted on exams of abdomen in veterinary radiology using Tl dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Veneziani, G. R.; Matsushima, L. C.; Campos, L. L. [Instituto de Pesquisas Energeticas e Nucleares, Gerencia de Metrologia das Radiacoes / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil); Filho, A. M., E-mail: venezianigr@gmail.com [Centro Universitario de Rio Petro - UNIRP, Rodovia Br 153 (Transbrasiliana), Km. 69 Sao Jose do Rio Preto, Sao Paulo (Brazil)

    2014-08-15

    The radiation protection has recently gained considerable attention in human medicine. In veterinary medicine has been some advances in radiodiagnostic and therapy for domestic animal like dogs and cats. It is notable the increase of the costs with domestic animals that are considered, by many people in the whole world, like members of family. However, an important parameter that must be taken into account is the increasing use of computed tomography and other equipment s that uses ionizing radiation, which may lead to comparatively high exposure of critical organs. The radiation dose is determined by the balance between therapeutic benefit and possible damage to surrounding normal tissues. This study aimed the evaluation of entrance surface-skin doses in dogs submitted to radiodiagnostic procedures of abdomen using the technique of thermoluminescent dosimetry (TLD). The radiation doses were measured using thermoluminescent dosimeters of LiF:Mg,Ti (TLD 100) and a dog phantom made with a plastic container, proportional to the dog size, fulfilled with water. (Author)

  4. Evaluation of entrance surface-skin doses in animals submitted on exams of abdomen in veterinary radiology using Tl dosimetry

    International Nuclear Information System (INIS)

    Veneziani, G. R.; Matsushima, L. C.; Campos, L. L.; Filho, A. M.

    2014-08-01

    The radiation protection has recently gained considerable attention in human medicine. In veterinary medicine has been some advances in radiodiagnostic and therapy for domestic animal like dogs and cats. It is notable the increase of the costs with domestic animals that are considered, by many people in the whole world, like members of family. However, an important parameter that must be taken into account is the increasing use of computed tomography and other equipment s that uses ionizing radiation, which may lead to comparatively high exposure of critical organs. The radiation dose is determined by the balance between therapeutic benefit and possible damage to surrounding normal tissues. This study aimed the evaluation of entrance surface-skin doses in dogs submitted to radiodiagnostic procedures of abdomen using the technique of thermoluminescent dosimetry (TLD). The radiation doses were measured using thermoluminescent dosimeters of LiF:Mg,Ti (TLD 100) and a dog phantom made with a plastic container, proportional to the dog size, fulfilled with water. (Author)

  5. Spatial distribution of tritium in surface water and assessment of ingestion dose

    International Nuclear Information System (INIS)

    Rupali, C.K.; Jha, S.K.; Tripathi, R.M.; Sonali, B.; Reddy, Priyanka

    2014-01-01

    The present study focuses on the distribution of tritium in drinking water samples from Mumbai and other suburban areas. Measurement of tritium in the drinking water was carried out using an ultra-low background LKB Quantulus Spectrometer, model 1220. The concentration of tritium in the drinking water ranged between ≤12.3-19.8TU with a geometric mean of 13.3TU. The observed values doesn't indicate any fresh input of tritium and are well within prescribed limit of 740 Bq/L (approx. 6,271.2 TU) given by USEPA for tritium ingestion through drinking water. The estimated dose due to tritium ingestion through drinking was 0.02 μSv/y which is negligible when compared to the limit of 1000 μSv/y assigned to general public. (author)

  6. Electrochemical machining of internal built-up surfaces of large-sized vessels for nuclear power plants

    International Nuclear Information System (INIS)

    Ryabchenko, N.N.; Pulin, V.Ya.

    1977-01-01

    Electrochemical machining (ECM) has been employed for finishing of mechanically processed inner surfaces of large lateral parts of construction bodies with welded 0Kh18N10T steel overlayer. The finishing technology developed reduces the surface roughness from 10 mcm to the standard 2.5 mcm at the efficiency of machining of 2-4 m 2 per hour

  7. Sci-Thur PM – Brachytherapy 06: 3D Printed Surface Applicators for High Dose Rate Brachytherapy

    International Nuclear Information System (INIS)

    Clarke, Scott; Yewondwossen, Mammo; Robar, James

    2016-01-01

    Purpose: The purpose of this work is to develop a new applicator for administering high dose rate (HDR) brachytherapy using 3D printing technology. Primary advantages of using a 3D printed applicator will be to offer a more streamlined approach for therapists and patients while achieving better conformity, reproducibility, and patient specific applicators. Methods: A phantom study was conducted to measure the effectiveness of a 3D printed surface applicator by analyzing tumours on three locations of the body: the foot, nose, and scalp. The applicator was designed using Eclipse and further modified using Blender to create the catheter tunnels before being printed on a Lulzbot Taz 5 3D printer. A radiation plan was made using Oncentra Brachytherapy for a control treatment option using Freiburg Flaps and one with the novel method of a 3D printed applicator. A comparative analysis was made using D90, D100, V100, V150, and V200 Results: The 3D printed applicator showed comparable dose coverage with significant improvements on highly irregular surfaces when analyzed against a plan made using Freiburg Flaps. Although both plans exhibited complete tumour coverage, the 3D applicator showed improvements in D90 and V150 and the 3D applicator had a dose homogeneity index (DHI) of 0.99 compared to a DHI of 0.97 for the control. Therapist prep time also dropped significantly due to the lack of need for a thermoplastic mesh. Conclusions: 3D printed applicators for treatment of superficial sites proved to offer more patient convenience, less prep time, better conformity and tighter margins.

  8. An evaluation of calculation parameters in the EGSnrc/BEAMnrc Monte Carlo codes and their effect on surface dose calculation

    International Nuclear Information System (INIS)

    Kim, Jung-Ha; Hill, Robin; Kuncic, Zdenka

    2012-01-01

    The Monte Carlo (MC) method has proven invaluable for radiation transport simulations to accurately determine radiation doses and is widely considered a reliable computational measure that can substitute a physical experiment where direct measurements are not possible or feasible. In the EGSnrc/BEAMnrc MC codes, there are several user-specified parameters and customized transport algorithms, which may affect the calculation results. In order to fully utilize the MC methods available in these codes, it is essential to understand all these options and to use them appropriately. In this study, the effects of the electron transport algorithms in EGSnrc/BEAMnrc, which are often a trade-off between calculation accuracy and efficiency, were investigated in the buildup region of a homogeneous water phantom and also in a heterogeneous phantom using the DOSRZnrc user code. The algorithms and parameters investigated include: boundary crossing algorithm (BCA), skin depth, electron step algorithm (ESA), global electron cutoff energy (ECUT) and electron production cutoff energy (AE). The variations in calculated buildup doses were found to be larger than 10% for different user-specified transport parameters. We found that using BCA = EXACT gave the best results in terms of accuracy and efficiency in calculating buildup doses using DOSRZnrc. In addition, using the ESA = PRESTA-I option was found to be the best way of reducing the total calculation time without losing accuracy in the results at high energies (few keV ∼ MeV). We also found that although choosing a higher ECUT/AE value in the beam modelling can dramatically improve computation efficiency, there is a significant trade-off in surface dose uncertainty. Our study demonstrates that a careful choice of user-specified transport parameters is required when conducting similar MC calculations. (note)

  9. Assessment of large aperture scintillometry for large-area surface energy fluxes over an irrigated cropland in north India

    Science.gov (United States)

    Danodia, Abhishek; Sehgal, V. K.; Patel, N. R.; Dhakar, R.; Mukherjee, J.; Saha, S. K.; Kumar, A. Senthil

    2017-07-01

    Amount of available net energy and its partitioning into sensible, latent and soil heat fluxes over an agricultural landscape are critical to improve estimation of evapotranspiration and modelling parse (ecosystem modelling, hydrological and meteorological modelling). Scintillometry is a peculiar and robust methodology to provide structure parameter of refractive index and energy balance. Scintillometer has proven for assessment of sensible and latent heat flux, which is based on the principle of Monin-Obukhov similarity theory. Scintillometer has been installed in the agricultural experimental farm of ICAR-Indian Agricultural Research Institute, New Delhi, with a spatial covering path length of 990 m of irrigated and cultivable agricultural landscape. This paper discusses the patterns of energy flux as diurnal and seasonal basis at scintillometer path which was mainly covered by maize in Kharif and wheat in Rabi season during a crop growing seasons of 2014-2015. The biophysical parameters (leaf area, soil moisture, crop height) were recorded at a temporal resolution of fortnight basis along the path length at usual sampling distance. The Bowen ratio value for both Kharif and Rabi season was 0.76 and 0.88, respectively by scintillometer. Leaf area index had a significantly positive correlation with latent heat flux (R2 =0.80) while a significantly negative correlation with sensible heat flux (R2{=}-0.79). Soil moisture had a significant negative correlation with sensible heat flux (R2{=}-0.68). The average evapotranspiration from crop land was 1.58 mm d^{-1} and total evapotranspiration was 543 mm over the 12 months study period. This study defines that large aperture scintillometer is robust instrument which can evaluate energy flux over a large area with a long term series time domain. Moreover, further studied should be conducted to use in crop simulation modelling, developing of new model with calibration and validation of remote sensing energy balance

  10. Measured and Monte Carlo simulated surface dose reduction for superficial X-rays incident on tissue with underlying air or bone.

    Science.gov (United States)

    Baines, John; Zawlodzka, Sylwia; Markwell, Tim; Chan, Millicent

    2018-02-01

    Measurement of surface dose reduction effects for superficial x-rays incident on tissue with underlying air or bone and comparison with Monte Carlo simulations of such effects. Further to investigate the correlation between surface dose reduction and changes in Compton backscatter spectra with tissue-bone separation. An Advanced Markus chamber with entrance window facing downstream on the surface of a solid water phantom was used to investigate changes in surface dose with an underlying air or bone interface located at various depths below the surface. Chamber readings were obtained for interface depths ranging from 1 to 100 mm using the 50 kV, 100 kV and 150 kV beams of an Xstrahl 150 x-ray unit, with field diameters (ϕ) = 2.5 cm and 5 cm. For each beam quality and field size the dose correction factor, DCF(t), namely the ratio of measured dose (t) to dose (t = 100 mm) was determined. Monte Carlo simulations of DCF(t) for air and bone interfaces in tissue are used to validate corresponding measured data. For a given beam and field size, the difference between simulated spectra with an air or bone interface at t = 3 mm was used to determine the Compton backscatter from bone at the surface. For air, DCF(t tube potentials corresponding factors, ϕ = 2.5 cm, for air(bone) are 0.94(0.96) and 0.92(0.99). Calculated DCF(t) based on Monte Carlo simulations are consistent with experimental observations to within 2%. Monte Carlo simulations of x-ray spectra demonstrate the presence of Compton backscatter from underlying bone in tissue. With bone at 3 mm depth calculated backscatter spectra at the tissue surface suggest that surface dose is influenced by the proximity of bone and that this effect depends on beam quality. This work demonstrates the feasibility of using an Advanced Markus chamber with entrance window facing downstream to investigate surface dose reduction with underlying air or bone in tissue. As the field size decreases and beam quality increases surface

  11. Effective dose calculations in conventional diagnostic X-ray examinations for adult and paediatric patients in a large Italian hospital

    International Nuclear Information System (INIS)

    Compagnone, G.; Pagan, L.; Bergamini, C.

    2005-01-01

    The effective dose E is an efficient and powerful parameter to study the radioprotection of the patient. In our hospital, eight radiological departments and more than 100 radiological X-ray tubes are present. The effective doses were calculated for adults and paediatric patients in 10 standard projections. To calculate E, first the entrance skin dose (ESD) was evaluated by a mathematical model that was validated by >400 direct measurements taken with an ionisation chamber on four different phantoms: the overall accuracy of the model was better than 12%. Second, to relate ESD to E, conversion coefficients calculated by Monte Carlo techniques were used. The E-values obtained were of the same order as those presented in the literature. Finally, we analysed how the study of E distributions among the various radiological departments can help to optimise the procedures, by identifying the most critical examinations or sub-optimal clinical protocols. (authors)

  12. Shear wave velocity structure in North America from large-scale waveform inversions of surface waves

    Science.gov (United States)

    Alsina, D.; Woodward, R.L.; Snieder, R.K.

    1996-01-01

    A two-step nonlinear and linear inversion is carried out to map the lateral heterogeneity beneath North America using surface wave data. The lateral resolution for most areas of the model is of the order of several hundred kilometers. The most obvious feature in the tomographic images is the rapid transition between low velocities in the technically active region west of the Rocky Mountains and high velocities in the stable central and eastern shield of North America. The model also reveals smaller-scale heterogeneous velocity structures. A high-velocity anomaly is imaged beneath the state of Washington that could be explained as the subducting Juan de Fuca plate beneath the Cascades. A large low-velocity structure extends along the coast from the Mendocino to the Rivera triple junction and to the continental interior across the southwestern United States and northwestern Mexico. Its shape changes notably with depth. This anomaly largely coincides with the part of the margin where no lithosphere is consumed since the subduction has been replaced by a transform fault. Evidence for a discontinuous subduction of the Cocos plate along the Middle American Trench is found. In central Mexico a transition is visible from low velocities across the Trans-Mexican Volcanic Belt (TMVB) to high velocities beneath the Yucatan Peninsula. Two elongated low-velocity anomalies beneath the Yellowstone Plateau and the eastern Snake River Plain volcanic system and beneath central Mexico and the TMVB seem to be associated with magmatism and partial melting. Another low-velocity feature is seen at depths of approximately 200 km beneath Florida and the Atlantic Coastal Plain. The inversion technique used is based on a linear surface wave scattering theory, which gives tomographic images of the relative phase velocity perturbations in four period bands ranging from 40 to 150 s. In order to find a smooth reference model a nonlinear inversion based on ray theory is first performed. After

  13. Exploring proximity effects and large depth of field in helium ion beam lithography: large-area dense patterns and tilted surface exposure.

    Science.gov (United States)

    Flatabø, Ranveig; Agarwal, Akshay; Hobbs, Richard; Greve, Martin Møeller; Holst, Bodil; Berggren, Karl K

    2018-04-13

    Helium ion beam lithography (HIL) is an emerging nanofabrication technique. It benefits from a reduced interaction volume compared to that of an electron beam of similar energy, and hence reduced long-range scattering (proximity effect), higher resist sensitivity and potentially higher resolution. Furthermore, the small angular spread of the helium ion beam gives rise to a large depth of field. This should enable patterning on tilted and curved surfaces without the need of any additional adjustments, such as laser-auto focus. So far, most work on helium ion beam lithography has been focused on exploiting the reduced proximity effect to reach single-digit nanometer resolution, and has thus been concentrated on single-pixel exposures over small areas. Here we explore two new areas of application. Firstly, we investigate the proximity effect in large area exposures and demonstrate HIL's capabilities in fabricating precise high-density gratings on large planar surfaces (100 µm × 100 µm, with pitch down to 35 nm). Secondly, we exploit the large depth of field by making the first HIL patterns on tilted surfaces (sample stage tilted 45◦). We demonstrate a depth of field greater than 100 µm for a resolution of about 20 nm. © 2018 IOP Publishing Ltd.

  14. Large area window on vacuum chamber surface for neutron scattering instruments

    International Nuclear Information System (INIS)

    Itoh, Shinichi; Yokoo, Tetsuya; Ueno, Kenji; Suzuki, Junichi; Teraoku, Takuji; Tsuchiya, Masao

    2012-01-01

    The feasibility of a large area window using a thin aluminum plate on the surface of the vacuum chamber for neutron scattering instruments at a pulsed neutron source was investigated. In the prototype investigation for a window with an area of 1m×1.4m and a thickness of 1 mm, the measured pressure dependence of the displacement agreed well with a calculation using a nonlinear strain–stress curve up to the plastic deformation region. In addition, we confirmed the repetition test up to 2000 pressurization-and-release cycles, which is sufficient for the lifetime of the vacuum chamber for neutron scattering instruments. Based on these investigations, an actual model of the window to be mounted on the vacuum chamber of the High Resolution Chopper Spectrometer (HRC) at J-PARC was designed. By using a calculated stress distribution on the window, the clamping structure capable of balancing the tension in the window was determined. In a model with a structure identical to the actual window, we confirmed the repetition test over more than 7000 pressurization-and-release cycles, which shows a lifetime long enough for the actual usage of the vacuum chamber on the HRC.

  15. Solving very large scattering problems using a parallel PWTD-enhanced surface integral equation solver

    KAUST Repository

    Liu, Yang

    2013-07-01

    The computational complexity and memory requirements of multilevel plane wave time domain (PWTD)-accelerated marching-on-in-time (MOT)-based surface integral equation (SIE) solvers scale as O(NtNs(log 2)Ns) and O(Ns 1.5); here N t and Ns denote numbers of temporal and spatial basis functions discretizing the current [Shanker et al., IEEE Trans. Antennas Propag., 51, 628-641, 2003]. In the past, serial versions of these solvers have been successfully applied to the analysis of scattering from perfect electrically conducting as well as homogeneous penetrable targets involving up to Ns ≈ 0.5 × 106 and Nt ≈ 10 3. To solve larger problems, parallel PWTD-enhanced MOT solvers are called for. Even though a simple parallelization strategy was demonstrated in the context of electromagnetic compatibility analysis [M. Lu et al., in Proc. IEEE Int. Symp. AP-S, 4, 4212-4215, 2004], by and large, progress in this area has been slow. The lack of progress can be attributed wholesale to difficulties associated with the construction of a scalable PWTD kernel. © 2013 IEEE.

  16. Curling probe measurement of a large-volume pulsed plasma with surface magnetic confinement

    Science.gov (United States)

    Pandey, A.; Tashiro, H.; Sakakibara, W.; Nakamura, K.; Sugai, H.

    2016-12-01

    A curling probe (CP) based on microwave resonance is applied to the measurement of electron density in a pulsed DC glow discharge under surface magnetic confinement (SMC) provided by a number of permanent magnets on a chamber wall. Owing to the SMC effects, a 1 m scale large-volume plasma is generated by a relatively low voltage (~1 kV) at low pressure (~1 Pa) in various gases (Ar, CH4, and C2H2). Temporal variation of the electron density is measured for pulse frequency f  =  0.5-25 kHz for various discharge-on times (T ON) with a high resolution time (~0.2 µs), using the on-point mode. In general, the electron density starts to increase at time t  =  0 after turn-on of the discharge voltage, reaches peak density at t  =  T ON, and then decreases after turn-off. The peak electron density is observed to increase with the pulse frequency f for constant T ON owing to the residual plasma. This dependence is successfully formulated using a semi-empirical model. The spatio-temporal evolution of the cathode sheath in the pulsed discharge is revealed by a 1 m long movable CP. The measured thickness of the high-voltage cathode fall in a steady state coincides with the value of the so-called Child-Langmuir sheath.

  17. [Study on plasma temperature of a large area surface discharge by optical emission spectrum].

    Science.gov (United States)

    Dong, Li-Fang; Tong, Guo-Liang; Zhang, Yu; Zhou, Bin

    2014-04-01

    A large area surface discharge was realized in air/argon gas mixture by designing a discharge device with water electrodes. By using optical emission spectrum, the variations of the molecular vibrational temperature, the mean energy of electron, and the electronic excitation temperature as a function of the gas pressure were studied. The nitrogen molecular vibrational temperature was calculated according to the emission line of the second positive band system of the nitrogen molecule (C3 pi(u) --> B 3 pi(g)). The electronic excitation temperature was obtained by using the intensity ratio of Ar I 763.51 nm (2P(6) --> 1S(5)) to Ar I 772.42 nm (2P(2) --> 1S(3)). The changes in the mean energy of electron were studied by the relative intensity ratio of the nitrogen molecular ion 391.4 nm to nitrogen 337.1 nm. It was found that the intensity of emission spectral line increases with the increase in the gas pressure, meanwhile, the outline and the ratios of different spectral lines intensity also change. The molecular vibrational temperature, the mean energy of electron, and the electronic excitation temperature decrease as the gas pressure increases from 0.75 x 10(5) Pa to 1 x 10(5) Pa.

  18. Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults

    International Nuclear Information System (INIS)

    Desai, Gaurav S.; Uppot, Raul N.; Kambadakone, Avinash R.; Yu, Elaine W.; Sahani, Dushyant V.

    2012-01-01

    To compare image quality and radiation dose using Adaptive Statistical Iterative Reconstruction (ASiR) and Filtered Back Projection (FBP) in patients weighing ≥91 kg. In this Institution Review Board-approved retrospective study, single-phase contrast-enhanced abdominopelvic CT examinations of 100 adults weighing ≥91 kg (mean body weight: 107.6 ± 17.4 kg range: 91-181.9 kg) with (1) ASiR and (2) FBP were reviewed by two readers in a blinded fashion for subjective measures of image quality (using a subjective standardized numerical scale and objective noise) and for radiation exposure. Imaging parameters and radiation dose results of the two techniques were compared within weight and BMI sub-categories. All examinations were found to be of adequate quality. Both subjective (mean = 1.4 ± 0.5 vs. 1.6 ± 0.6, P < 0.05) and objective noise (13.0 ± 3.2 vs.19.5 ± 5.7, P < 0.0001) were lower with ASiR. Average radiation dose reduction of 31.5 % was achieved using ASiR (mean CTDIvol. ASiR: 13.5 ± 7.3 mGy; FBP: 19.7 ± 9.0 mGy, P < 0.0001). Other measures of image quality were comparable between the two techniques. Trends for all parameters were similar in patients across weight and BMI sub-categories. In obese individuals, abdominal CT images reconstructed using ASiR provide diagnostic images with reduced image noise at lower radiation dose. circle CT images in obese adults are noisy, even with high radiation dose. (orig.)

  19. Application of optimized large surface area date stone (Phoenix dactylifera ) activated carbon for rhodamin B removal from aqueous solution: Box-Behnken design approach.

    Science.gov (United States)

    Danish, Mohammed; Khanday, Waheed Ahmad; Hashim, Rokiah; Sulaiman, Nurul Syuhada Binti; Akhtar, Mohammad Nishat; Nizami, Maniruddin

    2017-05-01

    Box-Behnken model of response surface methodology was used to study the effect of adsorption process parameters for Rhodamine B (RhB) removal from aqueous solution through optimized large surface area date stone activated carbon. The set experiments with three input parameters such as time (10-600min), adsorbent dosage (0.5-10g/L) and temperature (25-50°C) were considered for statistical significance. The adequate relation was found between the input variables and response (removal percentage of RhB) and Fisher values (F- values) along with P-values suggesting the significance of various term coefficients. At an optimum adsorbent dose of 0.53g/L, time 593min and temperature 46.20°C, the adsorption capacity of 210mg/g was attained with maximum desirability. The negative values of Gibb ' s free energy (ΔG) predicted spontaneity and feasibility of adsorption; whereas, positive Enthalpy change (ΔH) confirmed endothermic adsorption of RhB onto optimized large surface area date stone activated carbons (OLSADS-AC). The adsorption data were found to be the best fit on the Langmuir model supporting monolayer type of adsorption of RhB with maximum monolayer layer adsorption capacity of 196.08mg/g. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Fast Measurement and Reconstruction of Large Workpieces with Freeform Surfaces by Combining Local Scanning and Global Position Data

    Directory of Open Access Journals (Sweden)

    Zhe Chen

    2015-06-01

    Full Text Available In this paper, we propose a new approach for the measurement and reconstruction of large workpieces with freeform surfaces. The system consists of a handheld laser scanning sensor and a position sensor. The laser scanning sensor is used to acquire the surface and geometry information, and the position sensor is utilized to unify the scanning sensors into a global coordinate system. The measurement process includes data collection, multi-sensor data fusion and surface reconstruction. With the multi-sensor data fusion, errors accumulated during the image alignment and registration process are minimized, and the measuring precision is significantly improved. After the dense accurate acquisition of the three-dimensional (3-D coordinates, the surface is reconstructed using a commercial software piece, based on the Non-Uniform Rational B-Splines (NURBS surface. The system has been evaluated, both qualitatively and quantitatively, using reference measurements provided by a commercial laser scanning sensor. The method has been applied for the reconstruction of a large gear rim and the accuracy is up to 0.0963 mm. The results prove that this new combined method is promising for measuring and reconstructing the large-scale objects with complex surface geometry. Compared with reported methods of large-scale shape measurement, it owns high freedom in motion, high precision and high measurement speed in a wide measurement range.

  1. Omega-3 polyunsaturated fatty acids in large doses attenuate seizures, cognitive impairment, and hippocampal oxidative DNA damage in young kindled rats.

    Science.gov (United States)

    Abdel-Wahab, Basel A; Al-Qahtani, Jobran M; El-Safty, Samy A

    2015-01-01

    Omega-3 (OM3) dietary polyunsaturated fatty acids have promising seizure-protective effects, as well as enhancing effects of cognitive development and memory-related learning. This study aimed to explore the effect of large doses of OM3 on cognitive impairment and hippocampal oxidative DNA damage produced by seizures in epileptic children using a PTZ-kindled young rat model. Cognitive functions, biomarkers of oxidative stress, and DNA damage were assessed in PTZ-kindled young rats (30 mg/kg, i.p. once every other day for 13 injections) pretreated with OM3 (200-500 mg/kg, p.o.). Pretreatment with OM3 at the tested doses significantly attenuated PTZ-induced seizures and decreased cognitive impairment in both passive avoidance and elevated plus maze tests in the PTZ-kindled rats. Moreover, OM3 significantly attenuated the increase in hippocampal malondialdehyde and 8-hydroxy-2'-deoxyguanosine (8-OHdG) levels, as well as the decrease in reduced glutathione (GSH) levels and GSH-peroxidase activity induced by PTZ kindling, in a dose-related manner. Relatively large dose levels of OM3 (200-500 mg/kg) effectively attenuated seizures and their associated cognitive deficits, and reduced oxidative stress and hippocampal DNA damage in PTZ-kindled young rats. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  2. Estimates of surface deposition of radioactivity and radiation doses resulting from proposed NNTRP activities

    International Nuclear Information System (INIS)

    Gudiksen, P.H.; Peterson, K.R.

    1975-04-01

    The National Nuclear Test Readiness Program (NNTRP) has been developed by the AEC (now ERDA) and DOD to maintain a state of readiness for the prompt resumption of atmospheric nuclear testing if circumstances warrant such resumption. Such proposed tests would be conducted at the Pacific Test Site. The environmental consequences of the program were assessed. Estimations were made of the magnitude and distribution of radioactive debris deposited on the surface waters of the Pacific Ocean as a result of the test and of the total person-rem to the Continental U.S. and Hawaiian Islands populations. Since the proposed test series consists of a wide range of weapon yields to be detonated at various altitudes and the specific number and types of tests change with time according to national defense needs, a set of seven representative tests were selected for performing a parametric yield analysis at various burst locations and heights. The yields were selected to cover the low intermediate, intermediate, and low megaton ranges. The respective yields, detonation heights, and ground zero locations of the seven bursts were considered. The atmospheric transport and diffusion models that were used are described and the meteorological and radiological input data used, and the results of the calculations are included. (U.S.)

  3. Structural, chemical surface and transport modifications of regenerated cellulose dense membranes due to low-dose γ-radiation

    International Nuclear Information System (INIS)

    Vazquez, M.I.; Heredia-Guerrero, J.A.; Galan, P.; Benitez, J.J.; Benavente, J.

    2011-01-01

    Research highlights: → Low dose γ-radiation causes slight structural, chemical and morphological changes on regenerated cellulose films. → Induced structural changes increase the fragility of irradiated films. → Structural modifications reduce ion permeability of films. - Abstract: Modifications caused in commercial dense regenerated cellulose (RC) flat membranes by low-dose γ-irradiation (average photons energy of 1.23 MeV) are studied. Slight structural, chemical and morphological surface changes due to irradiation in three films with different RC content were determined by ATR-FTIR, XRD, XPS and AFM. Also, the alteration of their mechanical elasticity has been studied. Modification of membrane performance was determined from solute diffusion coefficient and effective membrane fixed charge concentration obtained from NaCl diffusion measurements. Induced structural changes defining new and effective fracture propagation directions are considered to be responsible for the increase of fragility of irradiated RC membranes. The same structural changes are proposed to explain the reduction of the membrane ion permeability through a mechanism involving either ion pathways elongation and/or blocking.

  4. Entrance surface dose distribution and organ dose assessment for cone-beam computed tomography using measurements and Monte Carlo simulations with voxel phantoms

    Science.gov (United States)

    Baptista, M.; Di Maria, S.; Vieira, S.; Vaz, P.

    2017-11-01

    Cone-Beam Computed Tomography (CBCT) enables high-resolution volumetric scanning of the bone and soft tissue anatomy under investigation at the treatment accelerator. This technique is extensively used in Image Guided Radiation Therapy (IGRT) for pre-treatment verification of patient position and target volume localization. When employed daily and several times per patient, CBCT imaging may lead to high cumulative imaging doses to the healthy tissues surrounding the exposed organs. This work aims at (1) evaluating the dose distribution during a CBCT scan and (2) calculating the organ doses involved in this image guiding procedure for clinically available scanning protocols. Both Monte Carlo (MC) simulations and measurements were performed. To model and simulate the kV imaging system mounted on a linear accelerator (Edge™, Varian Medical Systems) the state-of-the-art MC radiation transport program MCNPX 2.7.0 was used. In order to validate the simulation results, measurements of the Computed Tomography Dose Index (CTDI) were performed, using standard PMMA head and body phantoms, with 150 mm length and a standard pencil ionizing chamber (IC) 100 mm long. Measurements for head and pelvis scanning protocols, usually adopted in clinical environment were acquired, using two acquisition modes (full-fan and half fan). To calculate the organ doses, the implemented MC model of the CBCT scanner together with a male voxel phantom ("Golem") was used. The good agreement between the MCNPX simulations and the CTDIw measurements (differences up to 17%) presented in this work reveals that the CBCT MC model was successfully validated, taking into account the several uncertainties. The adequacy of the computational model to map dose distributions during a CBCT scan is discussed in order to identify ways to reduce the total CBCT imaging dose. The organ dose assessment highlights the need to evaluate the therapeutic and the CBCT imaging doses, in a more balanced approach, and the

  5. Adsorption of Polyanion onto Large Alpha Alumina Beads with Variably Charged Surface

    Directory of Open Access Journals (Sweden)

    Tien Duc Pham

    2014-01-01

    Full Text Available Adsorption of strong polyelectrolyte, poly(styrenesulfonate, PSS, of different molecular weights onto large α-Al2O3 beads was systematically investigated as functions of pH and NaCl concentrations. The ultraviolet (UV absorption spectra of PSS at different pH and salt concentrations confirmed that the structure of PSS is independent of pH. With the change of molecular weight from 70 kg/mol (PSS 70 to 1000 kg/mol (PSS 1000, adsorption amount of PSS increases and proton coadsorption on the surface of α-Al2O3 decreases at given pH and salt concentration. It suggests that higher molecular weight of PSS was less flat conformation than lower one. The adsorption density of PSS 70 and PSS 1000 decreases with decreasing salt concentrations, indicating that both electrostatic and nonelectrostatic interactions are involved. Experimental results of both PSS 70 and PSS 1000 adsorption isotherms onto α-Al2O3 at different pH and salt concentrations can be represented well by two-step adsorption model. The effects of molecular weight and salt concentration are explained by structure of adsorbed PSS onto α-Al2O3. The influence of added SDS on the isotherms is evaluated from the sequential adsorption. The SDS uptake onto α-Al2O3 in the presence of hemimicelles can prevent the adsorption of PSS at low concentration so that adsorption of PSS reduces with preadsorbed SDS.

  6. Monte Carlo based investigations of electron contamination from telecobalt unit head in build up region and its impact on surface dose.

    Science.gov (United States)

    Jagtap, A S; Palani Selvam, T; Patil, B J; Chavan, S T; Pethe, S N; Kulkarni, Gauri; Dahiwale, S S; Bhoraskar, V N; Dhole, S D

    2016-12-01

    A Telecobalt unit has wide range of applications in cancer treatments and is used widely in many countries all around the world. Estimation of surface dose in Cobalt-60 teletherapy machine becomes important since clinically useful photon beam consist of contaminated electrons during the patient treatment. EGSnrc along with the BEAMnrc user code was used to model the Theratron 780E telecobalt unit. Central axis depth dose profiles including surface doses have been estimated for the field sizes of 0×0, 6×6, 10×10, 15×15, 20×20, 25×25, 30×30cm 2 and at Source-to-surface distance (SSD) of 60 and 80cm. Surface dose was measured experimentally by the Gafchromic RTQA2 films and are in good agreement with the simulation results. The central axis depth dose data are compared with the data available from the British Journal of Radiology report no. 25. Contribution of contaminated electrons has also been calculated using Monte Carlo simulation by the different parts of the Cobalt-60 head for different field size and SSD's. Moreover, depth dose curve in zero area field size is calculated by extrapolation method and compared with the already published data. They are found in good agreement. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Expression of Fas and Bcl-2 and their relationship to apoptosis in spleen lymphocytes of mice irradiated with large dose 60Co γ-rays

    International Nuclear Information System (INIS)

    Gao Linlu; Cui Yufang; Yang Hong; Xia Guowei; Peng Ruiyun; Gao Yabin; Wang Dewen

    2000-01-01

    Objective: To investigate the expressions of Fas and Bcl-2 and their significance in apoptosis of spleen lymphocyte of mice after large dose γ-ray irradiation. Methods: At 3,6,12,24 h, 3, 7, 14 and 28 d after 6-20 Gy γ-ray irradiation mice were sacrificed and their spleens were removed. The expressions of Fas and Bcl-2 oncoprotein were analysed by LSAB immunohistochemical method. Results: The expression of Fas was strongly positive at 6 h after irradiation, especially in 6-12 Gy groups. It become less obvious along with prolongation of time after irradiation and almost disappeared on d 7 after irradiation. The expression of Bcl-2 was nearly negative at 6 h after irradiation, especially in 12-20 Gy groups, and did not recover on d 28 after irradiation. Conclusion: After large dose γ-ray irradiation the expression of Fas in mouse spleen lymphocytes shows a better relationship to lymphocyte apoptosis; in other words, Fas can prompt apoptosis. On the other hand, the action of Bcl-2 is reduced or even disappeared. Both of them play an important role in spleen lymphocyte apoptosis after large dose of γ-irradiation

  8. SU-E-T-232: Custom High-Dose-Rate Brachytherapy Surface Mold Applicators: The Importance Source to Skin Distance

    International Nuclear Information System (INIS)

    Park, S; Demanes, J; Kamrava, M

    2015-01-01

    Purpose: Surface mold applicators can be customized to fit irregular skin surfaces that are difficult to treat with other radiation therapy techniques. Optimal design of customized HDR skin brachytherapy is not well-established. We evaluated the impact of applicator thickness (source to skin distance) on target dosimetry. Methods: 27 patients had 34 treated sites: scalp 4, face 13, extremity 13, and torso 4. Custom applicators were constructed from 5–15 mm thick thermoplastic bolus molded over the skin lesion. A planar array of plastic brachytherapy catheters spaced 5–10 mm apart was affixed to the bolus. CT simulation was used to contour the target volume and to determine the prescription depth. Inverse planning simulated annealing followed by graphical optimization was used to plan and deliver 40–56 Gy in 8–16 fractions. Target coverage parameters (D90, Dmean, and V100) and dose uniformity (V110–200, D0.1cc, D1cc, and D2cc) were studied according to target depth (<5mm vs. ≥5mm) and applicator thickness (5–10mm vs. ≥10mm). Results: The average prescription depth was 4.2±1.5mm. The average bolus thickness was 9.2±2.4mm. The median CTV volume was 10.0 cc (0.2–212.4 cc). Similar target coverage was achieved with prescription depths of <5mm and ≥5mm (Dmean = 113.8% vs. 112.4% and D90 = 100.2% vs. 98.3%). The <5mm prescription depth plans were more uniform (D0.1cc = 131.8% vs. 151.8%). Bolus thickness <10mm vs. ≥10mm plans also had similar target coverage (Dmean = 118.2% vs. 110.7% and D90 = 100.1% vs. 99.0%). Applicators ≥10mm thick, however, provide more uniform target dosimetry (D0.1cc = 146.9% vs. 139.5%). Conclusion: Prescription depth is based upon the thickness of the lesion and upon the clinical needs of the patient. Applicators ≥10mm thick provide more dose uniformity than 5–10mm thick applicators. Applicator thickness is an important variable that should be considered during treatment planning to achieve optimal dose uniformity

  9. Computer aided display of multiple soft tissue anatomical surfaces for simultaneous structural and area-dose appreciation in 3D-radiationtherapy planning. 115

    International Nuclear Information System (INIS)

    Moore, C.J.; Mott, D.J.; Wilkinson, J.M.

    1987-01-01

    For radiotherapy applications a 3D display that includes soft tissues is required but the presentation of all anatomical structures is often unnecessary and is potentially confusing. A tumour volume and a small number of critical organs, usually embedded within other soft tissue anatomy, are likely to be all that can be clearly displayed when presented in a 3D format. The inclusion of dose data (in the form of isodose lines or surfaces) adds to the complication of any 3D display. A solution to this problem is to incorporate the presentation of dose distribution into the technique used to provide the illusion of 3D. This illusion can be provided by either depth cueing or by the hypothetical illumination of spatially defined object surfaces. The dose distribution from irradiation fields or, in the case of brachytherapy from radioactive sources, can be regarded as a source of illumination for tumour and critical organs. The intensity of illumination at any point on a tissue surface represents the dose at that point. Such an approach also allows the variation of dose over a given surface (and by extension, over the corresponding volume) to be quantified using histogram techniques. This may be of value in analysing and comparing techniques in which vulnerable tissue surfaces are irradiated. The planning of intracavitary treatments for cervical cancer is one application which might benefit from the display approach described above. Here the variation of dose over the mucosal surfaces of the bladder and the rectum is of particular interest, since dose related morbidity has often been reported following these treatments. 7 refs.; 8 figs

  10. Study of Near-Surface Models in Large-Eddy Simulations of a Neutrally Stratified Atmospheric Boundary Layer

    Science.gov (United States)

    Senocak, I.; Ackerman, A. S.; Kirkpatrick, M. P.; Stevens, D. E.; Mansour, N. N.

    2004-01-01

    Large-eddy simulation (LES) is a widely used technique in armospheric modeling research. In LES, large, unsteady, three dimensional structures are resolved and small structures that are not resolved on the computational grid are modeled. A filtering operation is applied to distinguish between resolved and unresolved scales. We present two near-surface models that have found use in atmospheric modeling. We also suggest a simpler eddy viscosity model that adopts Prandtl's mixing length model (Prandtl 1925) in the vicinity of the surface and blends with the dynamic Smagotinsky model (Germano et al, 1991) away from the surface. We evaluate the performance of these surface models by simulating a neutraly stratified atmospheric boundary layer.

  11. Large deformation and instability of soft hollow cylinder with surface effects

    OpenAIRE

    Wu, Jian; Liu, Mingchao; Wang, Zhenyu; Chen, C. Q.

    2017-01-01

    Surface stress, which is always neglected in classical elastic theories, has recently emerged as a key role in the mechanics of highly deformable soft solids. In this paper, the effect of surface stress on the deformation and instability of soft hollow cylinder are analyzed. By incorporating surface energy density function into the constitutive model of a hyper-elastic theory, explicit solutions are obtained for the deformation of soft hollow cylinder under the conditions of uniform pressure ...

  12. Surface growth mechanisms and structural faulting in the growth of large single and spherulitic titanosilicate ETS-4 crystals

    Science.gov (United States)

    Miraglia, Peter Q.; Yilmaz, Bilge; Warzywoda, Juliusz; Sacco, Albert

    2004-10-01

    Morphological, surface and crystallographic analyses of titanosilicate ETS-4 products, with diverse habits ranging from spherulitic particles composed of submicron crystallites to large single crystals, are presented. Pole figures revealed that crystal surfaces with a-, b- and c- axes corresponded to , and directions, respectively. Thus, technologically important 8-membered ring pores and titania chains in ETS-4 run along the b-axis of single crystals and terminate at the smallest crystal face. Height of the spiral growth steps observed on {1 0 0} and {0 0 1} surfaces corresponded to the interplanar spacings associated with their crystallographic orientation, and is equivalent to the thickness of building units that form the ETS-4 framework. Data suggest that the more viscous synthesis mixtures, with a large driving force for growth, increased the two- and three-dimensional nucleation, while limiting the transport of nutrients to the growth surface. These conditions increase the tendency for stacking fault formation on {1 0 0} surfaces and small angle branching, which eventually results in spherulitic growth. The growth of high quality ETS-4 single crystals (from less viscous synthesis mixtures) occurred at lower surface nucleation rates. Data suggest that these high quality, large crystals grew due to one-dimensional nucleation at spiral hillocks, and indicate that under these conditions un-faulted growth is preferred.

  13. Effect of large doses of 131I-19-iodocholesterol on metapyralone-induced adrenal cortical hyperplasia in dogs

    International Nuclear Information System (INIS)

    Anderson, B.G.; Beierwaltes, W.H.; Nishiyama, R.H.; Ice, R.D.

    1975-01-01

    The potential use of 131 I-19-iodocholesterol to treat ACTH excess Cushing's disease was evaluated in the dog. Three normal female dogs were given LD 50 radiation doses of 131 I-19-iodocholesterol without producing gross or histopathologically demonstrable change of the adrenals at autopsy 3 months later. The adrenal cortices of three dogs were made hyperplastic (to simulate the adrenal cortex in Cushing's disease) with ACTH and three with Metapyralone. In addition these six dogs were given LD 50 doses of 131 I-19-iodocholesterol. Three months after treatment, the adrenal glands of the ACTH-treated dogs were not enlarged, the cortex was thicker than normal, and there were no changes attributable to irradiation. At 3 months, the Metapyralone-treated dogs had enlarged adrenals, widening of the adrenal cortex, and no necrosis or other changes attributable to irradiation. It is concluded that a therapeutic trial of 131 I-19-iodocholesterol in the treatment of Cushing's disease is not indicated. (auth)

  14. Large-area homogeneous periodic surface structures generated on the surface of sputtered boron carbide thin films by femtosecond laser processing

    International Nuclear Information System (INIS)

    Serra, R.; Oliveira, V.; Oliveira, J.C.; Kubart, T.; Vilar, R.; Cavaleiro, A.

    2015-01-01

    Highlights: • Large-area LIPSS were formed by femtosecond laser processing B-C films surface. • The LIPSS spatial period increases with laser fluence (140–200 nm). • Stress-related sinusoidal-like undulations were formed on the B-C films surface. • The undulations amplitude (down to a few nanometres) increases with laser fluence. • Laser radiation absorption increases with surface roughness. - Abstract: Amorphous and crystalline sputtered boron carbide thin films have a very high hardness even surpassing that of bulk crystalline boron carbide (≈41 GPa). However, magnetron sputtered B-C films have high friction coefficients (C.o.F) which limit their industrial application. Nanopatterning of materials surfaces has been proposed as a solution to decrease the C.o.F. The contact area of the nanopatterned surfaces is decreased due to the nanometre size of the asperities which results in a significant reduction of adhesion and friction. In the present work, the surface of amorphous and polycrystalline B-C thin films deposited by magnetron sputtering was nanopatterned using infrared femtosecond laser radiation. Successive parallel laser tracks 10 μm apart were overlapped in order to obtain a processed area of about 3 mm 2 . Sinusoidal-like undulations with the same spatial period as the laser tracks were formed on the surface of the amorphous boron carbide films after laser processing. The undulations amplitude increases with increasing laser fluence. The formation of undulations with a 10 μm period was also observed on the surface of the crystalline boron carbide film processed with a pulse energy of 72 μJ. The amplitude of the undulations is about 10 times higher than in the amorphous films processed at the same pulse energy due to the higher roughness of the films and consequent increase in laser radiation absorption. LIPSS formation on the surface of the films was achieved for the three B-C films under study. However, LIPSS are formed under different

  15. Large-area homogeneous periodic surface structures generated on the surface of sputtered boron carbide thin films by femtosecond laser processing

    Energy Technology Data Exchange (ETDEWEB)

    Serra, R., E-mail: ricardo.serra@dem.uc.pt [SEG-CEMUC, Mechanical Engineering Department, University of Coimbra, Rua Luís Reis Santos, 3030-788 Coimbra (Portugal); Oliveira, V. [ICEMS-Instituto de Ciência e Engenharia de Materiais e Superfícies, Avenida Rovisco Pais no 1, 1049-001 Lisbon (Portugal); Instituto Superior de Engenharia de Lisboa, Avenida Conselheiro Emídio Navarro no 1, 1959-007 Lisbon (Portugal); Oliveira, J.C. [SEG-CEMUC, Mechanical Engineering Department, University of Coimbra, Rua Luís Reis Santos, 3030-788 Coimbra (Portugal); Kubart, T. [The Ångström Laboratory, Solid State Electronics, P.O. Box 534, SE-751 21 Uppsala (Sweden); Vilar, R. [Instituto Superior de Engenharia de Lisboa, Avenida Conselheiro Emídio Navarro no 1, 1959-007 Lisbon (Portugal); Instituto Superior Técnico, Avenida Rovisco Pais no 1, 1049-001 Lisbon (Portugal); Cavaleiro, A. [SEG-CEMUC, Mechanical Engineering Department, University of Coimbra, Rua Luís Reis Santos, 3030-788 Coimbra (Portugal)

    2015-03-15

    Highlights: • Large-area LIPSS were formed by femtosecond laser processing B-C films surface. • The LIPSS spatial period increases with laser fluence (140–200 nm). • Stress-related sinusoidal-like undulations were formed on the B-C films surface. • The undulations amplitude (down to a few nanometres) increases with laser fluence. • Laser radiation absorption increases with surface roughness. - Abstract: Amorphous and crystalline sputtered boron carbide thin films have a very high hardness even surpassing that of bulk crystalline boron carbide (≈41 GPa). However, magnetron sputtered B-C films have high friction coefficients (C.o.F) which limit their industrial application. Nanopatterning of materials surfaces has been proposed as a solution to decrease the C.o.F. The contact area of the nanopatterned surfaces is decreased due to the nanometre size of the asperities which results in a significant reduction of adhesion and friction. In the present work, the surface of amorphous and polycrystalline B-C thin films deposited by magnetron sputtering was nanopatterned using infrared femtosecond laser radiation. Successive parallel laser tracks 10 μm apart were overlapped in order to obtain a processed area of about 3 mm{sup 2}. Sinusoidal-like undulations with the same spatial period as the laser tracks were formed on the surface of the amorphous boron carbide films after laser processing. The undulations amplitude increases with increasing laser fluence. The formation of undulations with a 10 μm period was also observed on the surface of the crystalline boron carbide film processed with a pulse energy of 72 μJ. The amplitude of the undulations is about 10 times higher than in the amorphous films processed at the same pulse energy due to the higher roughness of the films and consequent increase in laser radiation absorption. LIPSS formation on the surface of the films was achieved for the three B-C films under study. However, LIPSS are formed under

  16. An approach for mapping large-area impervious surfaces: Synergistic use of Landsat-7 ETM+ and high spatial resolution imagery

    Science.gov (United States)

    Yang, Limin; Huang, Chengquan; Homer, Collin G.; Wylie, Bruce K.; Coan, Michael

    2003-01-01

    A wide range of urban ecosystem studies, including urban hydrology, urban climate, land use planning, and resource management, require current and accurate geospatial data of urban impervious surfaces. We developed an approach to quantify urban impervious surfaces as a continuous variable by using multisensor and multisource datasets. Subpixel percent impervious surfaces at 30-m resolution were mapped using a regression tree model. The utility, practicality, and affordability of the proposed method for large-area imperviousness mapping were tested over three spatial scales (Sioux Falls, South Dakota, Richmond, Virginia, and the Chesapeake Bay areas of the United States). Average error of predicted versus actual percent impervious surface ranged from 8.8 to 11.4%, with correlation coefficients from 0.82 to 0.91. The approach is being implemented to map impervious surfaces for the entire United States as one of the major components of the circa 2000 national land cover database.

  17. Radiation Dose Calculation for a Large Break Loss of Coolant Accident for the Dry Process Fuel Core with a Dual Failure

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jong Ho; Kim, Taek Mo; Choi, Hang Bok

    2005-05-15

    The compatibility of the direct use of spent pressurized water reactor fuel in Canada deuterium uranium (CANDU) reactors (DUPIC) fuel with the existing 713 MWe CANDU (CANDU-6) reactor has been analyzed for a limiting large break loss of coolant accident (LOCA) scenario such as 100% reactor outlet header break accompanied by a dual failure of the containment isolation logic. For the DUPIC fuel, the radiation source term was calculated for a 1/4 of fission products inventory in the fuel gap of the CANDU-6 reactor being steadily operated at the full power. However it was assumed that all the fission products of the DUPIC fuel core are instantaneously released to the containment building at 3 sec after the break, because the transient release model of the fission products has not yet been developed for the DUPIC fuel. The radiation effect was estimated for the personal dose of the critical age and the public dose. The calculations have shown that the personal doses are 231 mSv and 1954 mSv for the whole body and thyroid, respectively, which are blow the limits of 250 mSv and 2500 mSv. In fact, the personal doses of the DUPIC fuel core are higher than those of the natural uranium core, which is due to the assumption that all the fission products are instantaneously released into the containment building. Therefore if a realistic transient model of the fission products release is used, it is expected that the radiation doses of the DUPIC fuel core are much less that those of the natural uranium core. The public doses are 157 person-Sv and 1929 person-Sv for the whole body and thyroid, respectively, which are much less that the design limit of 10000 person-Sv. This study has confirmed that the personal and public doses of the DUPIC fuel core satisfy the design limits for the large break LOCA accompanied by a dual failure of the containment isolation logic.

  18. Spatial validation of large scale land surface models against monthly land surface temperature patterns using innovative performance metrics.

    Science.gov (United States)

    Koch, Julian; Siemann, Amanda; Stisen, Simon; Sheffield, Justin

    2016-04-01

    Land surface models (LSMs) are a key tool to enhance process understanding and to provide predictions of the terrestrial hydrosphere and its atmospheric coupling. Distributed LSMs predict hydrological states and fluxes, such as land surface temperature (LST) or actual evapotranspiration (aET), at each grid cell. LST observations are widely available through satellite remote sensing platforms that enable comprehensive spatial validations of LSMs. In spite of the availability of LST data, most validation studies rely on simple cell to cell comparisons and thus do not regard true spatial pattern information. This study features two innovative spatial performance metrics, namely EOF- and connectivity-analysis, to validate predicted LST patterns by three LSMs (Mosaic, Noah, VIC) over the contiguous USA. The LST validation dataset is derived from global High-Resolution-Infrared-Radiometric-Sounder (HIRS) retrievals for a 30 year period. The metrics are bias insensitive, which is an important feature in order to truly validate spatial patterns. The EOF analysis evaluates the spatial variability and pattern seasonality, and attests better performance to VIC in the warm months and to Mosaic and Noah in the cold months. Further, more than 75% of the LST variability can be captured by a single pattern that is strongly driven by air temperature. The connectivity analysis assesses the homogeneity and smoothness of patterns. The LSMs are most reliable at predicting cold LST patterns in the warm months and vice versa. Lastly, the coupling between aET and LST is investigated at flux tower sites and compared against LSMs to explain the identified LST shortcomings.

  19. Large breast size as a risk factor for late adverse effects of breast radiotherapy: Is residual dose inhomogeneity, despite 3D treatment planning and delivery, the main explanation?

    International Nuclear Information System (INIS)

    Goldsmith, Christy; Haviland, Joanne; Tsang, Yat; Sydenham, Mark; Yarnold, John

    2011-01-01

    Background and Purpose: Large breast size is associated with an increased risk of late adverse effects after breast conservation surgery and radiotherapy, even when 3D dosimetry is used. The purpose of this study is to test the hypothesis that residual dose inhomogeneity is sufficient to explain the association. Methods: Patients previously treated after breast conservation surgery with whole breast radiotherapy using 3D dosimetry and followed up in the UK FAST hypofractionation trial were selected for this analysis. The residual level of dose inhomogeneity across the whole breast treatment volume was used to test for association between residual dosimetry and post-treatment change in breast appearance at 2 years post-radiotherapy. Results: At 2 years, 201/279 (72%) of women had no change in photographic breast appearance, 61 (22%) had mild change and 17 (6%) had marked change. Breast size and dosimetry were both significantly associated with late effects in univariate analyses, but only breast size remained an independent significant risk factor for change in breast appearance when included in a multiple regression model together with other prognostic factors (p = 0.006 for trend). Conclusion: Large-breasted women are more likely to suffer change in breast size and shape after whole breast radiotherapy delivered using 3D dosimetry, but residual dose inhomogeneity is insufficient to explain the association.

  20. Use of 198 Au, with surface labelling, in the study of solid transport by bed load in large natural channels

    International Nuclear Information System (INIS)

    Nakahira, S.

    1987-01-01

    The present study aims to present a method of measuring the bed load transport using a radioisotope technique in large natural channels. This study describes the basic principles of radioisotope application in this field, emphasizing the use of 198 Au for surface labelling of a natural sediment. Moreover, it presents the theoretical aspects, critical analysis, recommendations and comments on the methodology proposed. (author)

  1. Surface infrastructure : cost, financing and schedules for large-dollar transportation projects

    Science.gov (United States)

    1998-02-01

    In fiscal year 1998, the federal government will distribute nearly $26 billion to states and localities for the construction and repair of the nation's surface transportation systems. To meet the nations' transportation needs, states and localities a...

  2. Analysis of Large Array Surface Myoelectric Potentials for the Low Back Muscles

    National Research Council Canada - National Science Library

    Reger, Steven

    2001-01-01

    .... The surface EMC distribution from the low back of 161 healthy and 44 acute LBP subjects were collected in three minimum stress postural positions including standing, 20 degrees of lumbar flexion...

  3. Dose-surface analysis for prediction of severe acute radio-induced skin toxicity in breast cancer patients.

    Science.gov (United States)

    Pastore, Francesco; Conson, Manuel; D'Avino, Vittoria; Palma, Giuseppe; Liuzzi, Raffaele; Solla, Raffaele; Farella, Antonio; Salvatore, Marco; Cella, Laura; Pacelli, Roberto

    2016-01-01

    Severe acute radiation-induced skin toxicity (RIST) after breast irradiation is a side effect impacting the quality of life in breast cancer (BC) patients. The aim of the present study was to develop normal tissue complication probability (NTCP) models of severe acute RIST in BC patients. We evaluated 140 consecutive BC patients undergoing conventional three-dimensional conformal radiotherapy (3D-CRT) after breast conserving surgery in a prospective study assessing acute RIST. The acute RIST was classified according to the RTOG scoring system. Dose-surface histograms (DSHs) of the body structure in the breast region were extracted as representative of skin irradiation. Patient, disease, and treatment-related characteristics were analyzed along with DSHs. NTCP modeling by Lyman-Kutcher-Burman (LKB) and by multivariate logistic regression using bootstrap resampling techniques was performed. Models were evaluated by Spearman's Rs coefficient and ROC area. By the end of radiotherapy, 139 (99%) patients developed any degree of acute RIST. G3 RIST was found in 11 of 140 (8%) patients. Mild-moderate (G1-G2) RIST was still present at 40 days after treatment in six (4%) patients. Using DSHs for LKB modeling of acute RIST severity (RTOG G3 vs. G0-2), parameter estimates were TD50=39 Gy, n=0.38 and m=0.14 [Rs = 0.25, area under the curve (AUC) = 0.77, p = 0.003]. On multivariate analysis, the most predictive model of acute RIST severity was a two-variable model including the skin receiving ≥30 Gy (S30) and psoriasis [Rs = 0.32, AUC = 0.84, p skin dose, the LKB n parameter was consistent with a surface effect for the skin. A good prediction performance was obtained using a data-driven multivariate model including S30 and a pre-existing skin disease (psoriasis) as a clinical factor.

  4. Facile fabrication of large-area and uniform silica nanospheres monolayer for efficient surface-enhanced Raman scattering

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Junqi; Zhao, Qianrun; Zhang, Ning; Man, Shi-Qing, E-mail: man_shiqing@yahoo.com

    2014-07-01

    A large-area efficient surface enhanced Raman scattering (SERS) substrate was deposited by Langmuir–Blodgett (LB) assembly and followed by sputter coating process. The interparticle distance of silica nanospheres was convenient and readily regulated by controlling the surface pressure. After sputter coating with a small amount of gold, the nanocomposite film was formed. The surfaces of nanostructures were characterized by scanning electron microscopy (SEM) and atomic force microscopy (AFM). The applicability of the nanostructures as SERS substrates was investigated by adsorption of crystal violet (CV) molecules. Different SERS effects were observed on deposited gold nanostructure upon large-area silica nanospheres monolayer with diameter of 250, 570 and 800 nm. It was also discussed the nanospheres with diameter of 250 nm for the fabrication of ordered arrangement of monolayers at surface pressures of 10–30 mN/m. These substrates with the close-packed nanospheres and sputtering of gold were found to exhibit high and uniform enhancement of the Raman signal across the entire surface. The averaged surface enhancement factor (ASEF) was calculated and discussed. The fabricated nanocomposite structures could be utilized as low-cost SERS-active substrates for biomedical and analytical chemistry field.

  5. Prediction of Acute Radiation Mucositis using an Oral Mucosal Dose Surface Model in Carbon Ion Radiotherapy for Head and Neck Tumors.

    Directory of Open Access Journals (Sweden)

    Atsushi Musha

    Full Text Available To evaluate the dose-response relationship for development of acute radiation mucositis (ARM using an oral mucosal dose surface model (OMDS-model in carbon ion radiotherapy (C-ion RT for head and neck tumors.Thirty-nine patients receiving C-ion RT for head and neck cancer were evaluated for ARM (once per week for 6 weeks according to the Common Terminology Criteria for Adverse Events (CTCAE, version 4.0, and the Radiation Therapy Oncology Group (RTOG scoring systems. The irradiation schedule typically used was 64 Gy [relative biological effectiveness (RBE] in 16 fractions for 4 weeks. Maximum point doses in the palate and tongue were compared with ARM in each patient.The location of the ARM coincided with the high-dose area in the OMDS-model. There was a clear dose-response relationship between maximum point dose and ARM grade assessed using the RTOG criteria but not the CTCAE. The threshold doses for grade 2-3 ARM in the palate and tongue were 43.0 Gy(RBE and 54.3 Gy(RBE, respectively.The OMDS-model was useful for predicting the location and severity of ARM. Maximum point doses in the model correlated well with grade 2-3 ARM.

  6. Large area substrate for surface enhanced Raman spectroscopy (SERS) using glass-drawing technique

    Science.gov (United States)

    Ivanov, Ilia N; Simpson, John T

    2012-06-26

    A method of making a large area substrate comprises drawing a plurality of tubes to form a plurality of drawn tubes, and cutting the plurality of drawn tubes into cut drawn tubes. Each cut drawn tube has a first end and a second end along the longitudinal direction of the respective cut drawn tube. The cut drawn tubes collectively have a predetermined periodicity. The method of making a large area substrate also comprises forming a metal layer on the first ends of the cut drawn tubes to provide a large area substrate.

  7. Measurement of entrance surface dose on an anthropomorphic thorax phantom using a miniature fiber-optic dosimeter.

    Science.gov (United States)

    Yoo, Wook Jae; Shin, Sang Hun; Jeon, Dayeong; Hong, Seunghan; Sim, Hyeok In; Kim, Seon Geun; Jang, Kyoung Won; Cho, Seunghyun; Youn, Won Sik; Lee, Bongsoo

    2014-04-01

    A miniature fiber-optic dosimeter (FOD) system was fabricated using a plastic scintillating fiber, a plastic optical fiber, and a multi-pixel photon counter to measure real-time entrance surface dose (ESD) during radiation diagnosis. Under varying exposure parameters of a digital radiography (DR) system, we measured the scintillating light related to the ESD using the sensing probe of the FOD, which was placed at the center of the beam field on an anthropomorphic thorax phantom. Also, we obtained DR images using a flat panel detector of the DR system to evaluate the effects of the dosimeter on image artifacts during posteroanterior (PA) chest radiography. From the experimental results, the scintillation output signals of the FOD were similar to the ESDs including backscatter simultaneously obtained using a semiconductor dosimeter. We demonstrated that the proposed miniature FOD can be used to measure real-time ESDs with minimization of DR image artifacts in the X-ray energy range of diagnostic radiology.

  8. Measurement of Entrance Surface Dose on an Anthropomorphic Thorax Phantom Using a Miniature Fiber-Optic Dosimeter

    Directory of Open Access Journals (Sweden)

    Wook Jae Yoo

    2014-04-01

    Full Text Available A miniature fiber-optic dosimeter (FOD system was fabricated using a plastic scintillating fiber, a plastic optical fiber, and a multi-pixel photon counter to measure real-time entrance surface dose (ESD during radiation diagnosis. Under varying exposure parameters of a digital radiography (DR system, we measured the scintillating light related to the ESD using the sensing probe of the FOD, which was placed at the center of the beam field on an anthropomorphic thorax phantom. Also, we obtained DR images using a flat panel detector of the DR system to evaluate the effects of the dosimeter on image artifacts during posteroanterior (PA chest radiography. From the experimental results, the scintillation output signals of the FOD were similar to the ESDs including backscatter simultaneously obtained using a semiconductor dosimeter. We demonstrated that the proposed miniature FOD can be used to measure real-time ESDs with minimization of DR image artifacts in the X-ray energy range of diagnostic radiology.

  9. Large area nanoscale patterning of silicon surfaces by parallel local oxidation

    Energy Technology Data Exchange (ETDEWEB)

    Losilla, N S; Martinez, J; Garcia, R [Instituto de Microelectronica de Madrid, CSIC, Isaac Newton 8, 28760 Tres Cantos, Madrid (Spain)

    2009-11-25

    The homogeneity and the reproducibility of parallel local oxidation have been improved by introducing a thin film of polymethylmethacrylate (PMMA) between the stamp and the silicon surface. The flexibility of the polymer film enables a homogeneous contact of the stamp with the silicon surface to be achieved. The oxides obtained yield better aspect ratios compared with the ones created with no PMMA layer. The pattern is formed when a bias voltage is applied between the stamp and the silicon surface for 1 min. The patterning can be done by a step and repeat technique and is reproducible across a centimetre length scale. Once the oxide nanostructures have been created, the polymer is removed by etching in acetone. Finally, parallel local oxidation is applied to fabricate silicon nanostructures and templates for the growth of organic molecules.

  10. Low-Stress Silicon Cladding for Surface Finishing Large UVOIR Mirrors Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase I research, ZeCoat Corporation will develop an affordable, low-stress silicon cladding process which is super-polishable for large UVOIR mirrors. The...

  11. Effect of fructose diphosphate combined with large-dose vitamin C therapy on the myocardial oxidative stress injury after neonatal asphyxia

    Directory of Open Access Journals (Sweden)

    Chun-Hua Liang1

    2017-04-01

    Full Text Available Objective: To study the effect of fructose diphosphate combined with large-dose vitamin C therapy on the myocardial oxidative stress injury after neonatal asphyxia. Methods: 40 patients with neonatal asphyxia who were treated in our hospital between June 2013 and April 2016 were collected and divided into the control group (n=20 who received large-dose vitamin C therapy and the observation group (n=20 who received fructose diphosphate combined with large-dose vitamin C therapy according to the double-blind randomized control method, and the treatment lasted for 10 d. Immediately after admission and after 10 d of treatment, RIA method was used to detect the serum levels of oxidative stress indexes, color Doppler diasonograph was used to determine left cardiac function parameters, and the myocardial enzyme spectrum detector was used to determine myocardial enzyme spectrum index levels. Results: Immediately after admission, the differences in the systemic oxidative stress degree, the left cardiac function damage degree and the myocardial enzyme spectrum index levels were not statistically significant between two groups of patients (P>0.05. After 10 d of treatment, serum malondialdehyde (MDA, advanced oxidation protein products (AOPP, creatine kinase isoenzyme (CK-MB, N-terminal pro-brain natriuretic peptide (Nt-proBNP, heart-type fatty acid-binding protein (H-FABP and troponin I (cTnI contents of observation group were lower than those of control group (P<0.05 while superoxide dismutase (SOD content was higher than that of control group (P<0.05, and the left cardiac function parameter ejection time (ET level was higher than that of control group (P<0.05 while left ventricular isovolumetric contraction time (ICT and left ventricular isovolumetric relaxation time (IRT levels were lower than those of control group (P<0.05. Conclusion: Fructose diphosphate combined with large-dose vitamin C can reduce the systemic oxidative stress of neonatal asphyxia

  12. Downscaling the Impacts of Large-Scale LUCC on Surface Temperature along with IPCC RCPs: A Global Perspective

    Directory of Open Access Journals (Sweden)

    Xiangzheng Deng

    2014-04-01

    Full Text Available This study focuses on the potential impacts of large-scale land use and land cover changes (LUCC on surface temperature from a global perspective. As important types of LUCC, urbanization, deforestation, cultivated land reclamation, and grassland degradation have effects on the climate, the potential changes of the surface temperature caused by these four types of large-scale LUCC from 2010 to 2050 are downscaled, and this issue analyzed worldwide along with Representative Concentration Pathways (RCPs of the Intergovernmental Panel on Climate Change (IPCC. The first case study presents some evidence of the effects of future urbanization on surface temperature in the Northeast megalopolis of the United States of America (USA. In order to understand the potential climatological variability caused by future forest deforestation and vulnerability, we chose Brazilian Amazon region as the second case study. The third selected region in India as a typical region of cultivated land reclamation where the possible climatic impacts are explored. In the fourth case study, we simulate the surface temperature changes caused by future grassland degradation in Mongolia. Results show that the temperature in built-up area would increase obviously throughout the four land types. In addition, the effects of all four large-scale LUCC on monthly average temperature change would vary from month to month with obviously spatial heterogeneity.

  13. Shallow to Deep Convection Transition over a Heterogeneous Land Surface Using the Land Model Coupled Large-Eddy Simulation

    Science.gov (United States)

    Lee, J.; Zhang, Y.; Klein, S. A.

    2017-12-01

    The triggering of the land breeze, and hence the development of deep convection over heterogeneous land should be understood as a consequence of the complex processes involving various factors from land surface and atmosphere simultaneously. That is a sub-grid scale process that many large-scale models have difficulty incorporating it into the parameterization scheme partly due to lack of our understanding. Thus, it is imperative that we approach the problem using a high-resolution modeling framework. In this study, we use SAM-SLM (Lee and Khairoutdinov, 2015), a large-eddy simulation model coupled to a land model, to explore the cloud effect such as cold pool, the cloud shading and the soil moisture memory on the land breeze structure and the further development of cloud and precipitation over a heterogeneous land surface. The atmospheric large scale forcing and the initial sounding are taken from the new composite case study of the fair-weather, non-precipitating shallow cumuli at ARM SGP (Zhang et al., 2017). We model the land surface as a chess board pattern with alternating leaf area index (LAI). The patch contrast of the LAI is adjusted to encompass the weak to strong heterogeneity amplitude. The surface sensible- and latent heat fluxes are computed according to the given LAI representing the differential surface heating over a heterogeneous land surface. Separate from the surface forcing imposed from the originally modeled surface, the cases that transition into the moist convection can induce another layer of the surface heterogeneity from the 1) radiation shading by clouds, 2) adjusted soil moisture pattern by the rain, 3) spreading cold pool. First, we assess and quantifies the individual cloud effect on the land breeze and the moist convection under the weak wind to simplify the feedback processes. And then, the same set of experiments is repeated under sheared background wind with low level jet, a typical summer time wind pattern at ARM SGP site, to

  14. Kinematic behaviour of a large earthflow defined by surface displacement monitoring, DEM differencing, and ERT imaging

    Czech Academy of Sciences Publication Activity Database

    Prokešová, R.; Kardoš, M.; Tábořík, Petr; Medveďová, A.; Stacke, V.; Chudý, F.

    2014-01-01

    Roč. 224, NOV 1 (2014), s. 86-101 ISSN 0169-555X R&D Projects: GA MŠk LM2010008 Institutional support: RVO:67985891 Keywords : earthflow * surface displacement * strain modelling * DEM differencing * kinematic behaviour Subject RIV: DE - Earth Magnetism, Geodesy, Geography Impact factor: 2.577, year: 2013

  15. Adsorption configuration effects on the surface diffusion of large organic molecules

    DEFF Research Database (Denmark)

    Sato, F.; Legoas, S.B.; Hummelink, F.

    2010-01-01

    results show that it has its physical basis on the interplay of the molecular hydrogens and the Cu(110) atomic spacing, which is a direct consequence of the matching between molecule and surface dimensions. This information could be used to find new molecules capable of displaying lock-and-key behavior...

  16. Large Optical Nonlinearity of Surface Plasmon Modes on Thin Gold Films

    DEFF Research Database (Denmark)

    Huck, Alexander; Witthaut, Dirk; Kumar, Shailesh

    2013-01-01

    We investigate the optical nonlinear effects of a long-range surface plasmon polariton mode propagating on a thin gold film. These effects may play a key role in the design of future nanophotonic circuits as they allow for the realization of active plasmonic elements. We demonstrate a significant...

  17. The effects of large-scale atmospheric flows on berylium-7 activity concentration in surface air.

    Science.gov (United States)

    Arkian, Foroozan; Meshkatee, Amir-Hussain; Bidokhti, Ali Akbar

    2010-09-01

    Understanding the exchange mechanism between stratosphere and troposphere is one of the most important concerns of meteorologists and climatologists for decades. Different methods are being adopted to study those mechanisms. One of those methods is the study upon the tropospheric concentration of conserve or passive entities with stratospheric origin. One of those passive entities is (7)Be that is produced upon the incident of cosmic rays on light atmospheric nuclei in the stratosphere. The availability of 5 years observations of (7)Be concentration in surface air in Tehran (35 degrees 41(') N, 51 degrees 18(') E) encouraged us to investigate meteorological condition effect on the surface concentration of (7)Be. Also, the intention was to see if there was any intrusion of stratospheric air into the troposphere at the time of high surface concentration of (7)Be and scavenging mechanism when the concentration was low. During the course of this study, it has been found that (7)Be concentration is high whenever there is a jet stream over Tehran. Since high-level jet streams normally form near tropopause folding, it could be interpreted as a sign of the intrusion of stratospheric air into the troposphere. It was also found that high concentration of (7)Be in the Tehran surface air in summer is associated with an upper ridge on 500 hPa surface located east of the city, and low concentration in winter is associated with an upper trough. The latter normally is seen whenever there is precipitation that suggests wet scavenging could be the reason for that observed low concentration.

  18. In-situ monitoring of surface post-processing in large aperture fused silica optics with Optical Coherence Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Guss, G M; Bass, I l; Hackel, R P; Mailhiot, C; Demos, S G

    2008-02-08

    Optical Coherence Tomography is explored as a method to image laser-damage sites located on the surface of large aperture fused silica optics during post-processing via CO{sub 2} laser ablation. The signal analysis for image acquisition was adapted to meet the sensitivity requirements for this application. A long-working distance geometry was employed to allow imaging through the opposite surface of the 5-cm thick optic. The experimental results demonstrate the potential of OCT for remote monitoring of transparent material processing applications.

  19. Process for producing curved surface of membrane rings for large containers, particulary for prestressed concrete pressure vessels of nuclear reactors

    International Nuclear Information System (INIS)

    Kumpf, H.

    1977-01-01

    Membrane rings for large pressure vessels, particularly for prestressed-concrete pressure vessels, often have curved surfaces. The invention describes a process of producing these at site, which is particularly advantageous as the forming and installation of the vessel component coincide. According to the invention, the originally flat membrane ring is set in a predetermined position, is then pressed in sections by a forming tool (with a preformed support ring as opposite tool), and shaped. After this, the shaped parts are welded to the ring-shaped wall parts of the large vessel. The manufacture of single and double membrane rings arrangements is described. (HP) [de

  20. Turbulent Flow and Large Surface Wave Events in the Marine Boundary Layers

    Science.gov (United States)

    2013-08-22

    AIAA, 2011 • Gulf of Mexico Oil Spill and Ecosystem Conference, 2013 150 s time averaged streamlines (U,W) Vectors and Pressure over Incipient...observations78 of the sea surface from field campaigns ( Romero and Melville 2010). Although our main79 computational target is building a turbulence resolving...the LES; this observational data is generally unknown. In the absence of a full description228 of the wavefield kinematics and dynamics (e.g., Romero

  1. GPM and TRMM Radar Vertical Profiles and Impact on Large-scale Variations of Surface Rain

    Science.gov (United States)

    Wang, J. J.; Adler, R. F.

    2017-12-01

    Previous studies by the authors using Tropical Rainfall Measuring Mission (TRMM) and Global Precipitation Measurement (GPM) data have shown that TRMM Precipitation Radar (PR) and GPM Dual-Frequency Precipitation Radar (DPR) surface rain estimates do not have corresponding amplitudes of inter-annual variations over the tropical oceans as do passive microwave observations by TRMM Microwave Imager (TMI) and GPM Microwave Imager (GMI). This includes differences in surface temperature-rainfall variations. We re-investigate these relations with the new GPM Version 5 data with an emphasis on understanding these differences with respect to the DPR vertical profiles of reflectivity and rainfall and the associated convective and stratiform proportions. For the inter-annual variation of ocean rainfall from both passive microwave (TMI and GMI) and active microwave (PR and DPR) estimates, it is found that for stratiform rainfall both TMI-PR and GMI-DPR show very good correlation. However, the correlation of GMI-DPR is much higher than TMI-PR in convective rainfall. The analysis of vertical profile of PR and DPR rainfall during the TRMM and GPM overlap period (March-August, 2014) reveals that PR and DPR have about the same rainrate at 4km and above, but PR rainrate is more than 10% lower that of DPR at the surface. In other words, it seems that convective rainfall is better defined with DPR near surface. However, even though the DPR results agree better with the passive microwave results, there still is a significant difference, which may be a result of DPR retrieval error, or inherent passive/active retrieval differences. Monthly and instantaneous GMI and DPR data need to be analyzed in details to better understand the differences.

  2. Mathematical model for biomolecular quantification using large-area surface-enhanced Raman spectroscopy mapping

    DEFF Research Database (Denmark)

    Palla, Mirkó; Bosco, Filippo; Yang, Jaeyoung

    2015-01-01

    Surface-enhanced Raman spectroscopy (SERS) based on nanostructured platforms is a promising technique for quantitative and highly sensitive detection of biomolecules in the field of analytical biochemistry. Here, we report a mathematical model to predict experimental SERS signal (or hotspot......) intensity distributions of target molecules on receptor-functionalized nanopillar substrates for biomolecular quantification. We demonstrate that by utilizing only a small set of empirically determined parameters, our general theoretical framework agrees with the experimental data particularly well...

  3. Surface hydrophobic co-modification of hollow silica nanoparticles toward large-area transparent superhydrophobic coatings.

    Science.gov (United States)

    Gao, Liangjuan; He, Junhui

    2013-04-15

    The present paper reports a novel, simple, and efficient approach to fabricate transparent superhydrophobic coatings on glass substrates by spray-coating stearic acid (STA) and 1H,1H,2H,2H-perflurooctyltriethoxysilane (POTS) co-modified hollow silica nanoparticles (SPHSNs), the surfaces of which were hydrophobic. The surface wettability of coatings was dependent on the conditions of post-treatment: the water contact angle of coating increased and then leveled off with increase in either the drying temperature or the drying time. When the coating was treated at 150°C for 5h, the water contact angle was as high as 160° and the sliding angle was lower than 1°, reaching excellent superhydrophobicity. They remained 159° and ≤1°, respectively, even after 3months storage under indoor conditions (20°C, 20%RH), demonstrating the long time stability of coating superhydrophobicity. The coating was robust both to the impact of water droplets (297 cm/s) and to acidic (pH=1) and basic (pH=14) droplets. It showed good transparency in the visible-near infrared spectral range, and the maximum transmittance reached as high as 89%. Fourier transform infrared spectroscopy, transmission electron microscopy, differential scanning calorimetry, and thermogravimetric analysis were used to investigate the interactions among STA, POTS, and hollow silica nanoparticles (HSNs). Scanning electron microscopy and atomic force microscopy were used to observe and estimate the morphology and surface roughness of coatings. Optical properties were characterized by a UV-visible-near infrared spectrophotometer. Surface wettability was studied by a contact angle/interface system. The enhancement of hydrophobicity to superhydrophobicity by post-treatment was discussed based on the transition from the Wenzel state to the Cassie state. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. Large accumulation of micro-sized synthetic polymer particles in the sea surface microlayer.

    Science.gov (United States)

    Song, Young Kyoung; Hong, Sang Hee; Jang, Mi; Kang, Jung-Hoon; Kwon, Oh Youn; Han, Gi Myung; Shim, Won Joon

    2014-08-19

    Determining the exact abundance of microplastics on the sea surface can be susceptible to the sampling method used. The sea surface microlayer (SML) can accumulate light plastic particles, but this has not yet been sampled. The abundance of microplastics in the SML was evaluated off the southern coast of Korea. The SML sampling method was then compared to bulk surface water filtering, a hand net (50 μm mesh), and a Manta trawl net (330 μm mesh). The mean abundances were in the order of SML water > hand net > bulk water > Manta trawl net. Fourier transform infrared spectroscopy (FTIR) identified that alkyds and poly(acrylate/styrene) accounted for 81 and 11%, respectively, of the total polymer content of the SML samples. These polymers originated from paints and the fiber-reinforced plastic (FRP) matrix used on ships. Synthetic polymers from ship coatings should be considered to be a source of microplastics. Selecting a suitable sampling method is crucial for evaluating microplastic pollution.

  5. Process variations in surface nano geometries manufacture on large area substrates

    DEFF Research Database (Denmark)

    Calaon, Matteo; Hansen, Hans Nørgaard; Tosello, Guido

    2014-01-01

    The need of transporting, treating and measuring increasingly smaller biomedical samples has pushed the integration of a far reaching number of nanofeatures over large substrates size in respect to the conventional processes working area windows. Dimensional stability of nano fabrication processes...

  6. Effective half-life of the large dose 131I in treatment of thyroid cancer patients and the relevant influence factors

    International Nuclear Information System (INIS)

    Objective: To study the effective half-life of large dose of 131 I in treatment of thyroid cancer patients and to analyze the relevant influence factors. Methods: Twenty patients were included in the study (12 patients were treated for the first time and 8 patients had been treated repeatedly). The radiation exposure rate of the patients was measured at the same intervals within 0 - 9 d. The effective half-life was derived from one compartment model based on the data measured. Results: The effective half-life was 0.6492 d for the first time treatment group and 0.5123 d for repeated treatment group. The difference was statistically significant. The effective half-life in local metastasis and lung metastasis were 0.4997 d and 0.6105 d, respectively. The difference was also statistically significant. Conclusions: The effective half-life of large dose 131 I in treatment of thyroid cancer patients was affected by treatment times and metastasis position. The result suggests that some measures should be taken to increase the effective half-life in order to get better treatment results

  7. Low-Dose Aspirin in Early Gestation for Prevention of Preeclampsia and Small-for-Gestational-Age Neonates: Meta-analysis of Large Randomized Trials.

    Science.gov (United States)

    Roberge, Stéphanie; Sibai, Baha; McCaw-Binns, Affette; Bujold, Emmanuel

    2016-07-01

    Objectives Meta-analyses of small to moderate size randomized controlled trials (RCTs) suggested that aspirin started before 17 weeks' gestation reduces the risk of preeclampsia and small-for-gestational-age (SGA) neonates. We evaluated data from large randomized trials originally excluded from meta-analyses. Methods We performed meta-analyses of RCTs including more than 350 participants that compared aspirin to placebo during pregnancy. Corresponding authors were contacted to obtain data according to gestational age. Outcomes included preeclampsia, severe preeclampsia, and SGA. Relative risks (RRs) with their 95% confidence intervals (CIs) were calculated. Results Data for women recruited before 17 weeks' gestation were obtained for three (50%) of the six eligible trials for a total of 11,949 participants including 3,293 recruited before 17 weeks' gestation with available data. We observed no impact of low-dose aspirin (60 mg) started before 17 weeks' gestation on the risk of preeclampsia (RR: 0.93; 95% CI: 0.75-1.15), severe preeclampsia (RR: 0.96; 95% CI: 0.71-1.28), or SGA (RR: 0.84; 95% CI: 0.56-1.26) and it was not statistically different than when started at or after 17 weeks' gestation. Conclusion Data from large randomized trials do not support greater benefits of low-dose aspirin (at 60 mg daily) when started before 17 weeks' gestation for the prevention of preeclampsia or SGA. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  8. Dosimetric coverage of the prostate, normal tissue sparing, and acute toxicity with high-dose-rate brachytherapy for large prostate volumes

    Energy Technology Data Exchange (ETDEWEB)

    Yang, George; Strom, Tobin J.; Shrinath, Kushagra; Mellon, Eric A.; Fernandez, Daniel C.; Biagioli, Matthew C. [Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL (United States); Wilder, Richard B., E-mail: mcbiagioli@yahoo.com [Cancer Treatment Centers of America, Newnan, GA (United States)

    2015-05-15

    Purpose: to evaluate dosimetric coverage of the prostate, normal tissue sparing, and acute toxicity with HDR brachytherapy for large prostate volumes. Materials and methods: one hundred and two prostate cancer patients with prostate volumes >50 mL (range: 5-29 mL) were treated with high-dose-rate (HDR) brachytherapy ± intensity modulated radiation therapy (IMRT) to 4,500 cGy in 25 daily fractions between 2009 and 2013. HDR brachytherapy monotherapy doses consisted of two 1,350-1,400 cGy fractions separated by 2-3 weeks, and HDR brachytherapy boost doses consisted of two 950-1,150 cGy fractions separated by 4 weeks. Twelve of 32 (38%) unfavorable intermediate risk, high risk, and very high risk patients received androgen deprivation therapy. Acute toxicity was graded according to the Common Terminology Criteria for Adverse Events (CTCAE) version 4. Results: median follow-up was 14 months. Dosimetric goals were achieved in over 90% of cases. Three of 102 (3%) patients developed Grade 2 acute proctitis. No variables were significantly associated with Grade 2 acute proctitis. Seventeen of 102 (17%) patients developed Grade 2 acute urinary retention. American Urological Association (AUA) symptom score was the only variable significantly associated with Grade 2 acute urinary retention (p-0.04). There was no ≥ Grade 3 acute toxicity. Conclusions: dosimetric coverage of the prostate and normal tissue sparing were adequate in patients with prostate volumes >50 mL. Higher pre-treatment AUA symptom scores increased the relative risk of Grade 2 acute urinary retention. However, the overall incidence of acute toxicity was acceptable in patients with large prostate volumes. (author)

  9. Dosimetric Coverage of the Prostate, Normal Tissue Sparing, and Acute Toxicity with High-Dose-Rate Brachytherapy for Large Prostate Volumes

    Directory of Open Access Journals (Sweden)

    George Yang

    2015-06-01

    Full Text Available ABSTRACTPurposeTo evaluate dosimetric coverage of the prostate, normal tissue sparing, and acute toxicity with HDR brachytherapy for large prostate volumes.Materials and MethodsOne hundred and two prostate cancer patients with prostate volumes >50 mL (range: 5-29 mL were treated with high-dose-rate (HDR brachytherapy ± intensity modulated radiation therapy (IMRT to 4,500 cGy in 25 daily fractions between 2009 and 2013. HDR brachytherapy monotherapy doses consisted of two 1,350-1,400 cGy fractions separated by 2-3 weeks, and HDR brachytherapy boost doses consisted of two 950-1,150 cGy fractions separated by 4 weeks. Twelve of 32 (38% unfavorable intermediate risk, high risk, and very high risk patients received androgen deprivation therapy. Acute toxicity was graded according to the Common Terminology Criteria for Adverse Events (CTCAE version 4.ResultsMedian follow-up was 14 months. Dosimetric goals were achieved in over 90% of cases. Three of 102 (3% patients developed Grade 2 acute proctitis. No variables were significantly associated with Grade 2 acute proctitis. Seventeen of 102 (17% patients developed Grade 2 acute urinary retention. American Urological Association (AUA symptom score was the only variable significantly associated with Grade 2 acute urinary retention (p=0.04. There was no ≥ Grade 3 acute toxicity.ConclusionsDosimetric coverage of the prostate and normal tissue sparing were adequate in patients with prostate volumes >50 mL. Higher pre-treatment AUA symptom scores increased the relative risk of Grade 2 acute urinary retention. However, the overall incidence of acute toxicity was acceptable in patients with large prostate volumes.

  10. Largely enhanced near band edge emission of ultrathin zinc oxide nanowire/gold nanoparticles composites by surface plasmon resonance

    Science.gov (United States)

    Li, Lei; Wang, Chenying; Han, Feng; Yang, Shuming; Jing, Weixuan; Jiang, Zhuangde

    2018-03-01

    Ultrathin zinc oxide nanowires with diameter less than 50 nm were synthesized by polyethyleneimine assisted solution method. Zinc oxide nanowire near band edge emission was enhanced obviously by gold nanoparticles coating, and a max 26 times enhancement was realized. The defects caused visible light emission was also quenched to noise level when gold was deposited more than 10 s. The large near band edge emission enhancement was caused by surface plasmon resonance mediated luminescent energy transfer, which absorbed the visible light energy and transferred to the near band edge emission. The large surface to volume ratio enhanced the coupling strength between gold nanoparticles and ultrathin zinc oxide nanowires. This research provide a method to improve the luminescent efficiency of zinc oxide nanowires.

  11. Constraining MODIS snow albedo at large solar zenith angles: Implications for the surface energy budget in Greenland

    OpenAIRE

    Wang, Xianwei; Zender, Charles S

    2010-01-01

    An understanding of the surface albedo of high latitudes is crucial for climate change studies. MODIS albedo retrievals flagged as high-quality compare well with in situ Greenland Climate Network (GC-Net) measurements but cover too small an area to fully characterize Greenland's albedo in nonsummer months. In contrast, poor quality MODIS retrievals provide adequate spatiotemporal coverage, but are not recommended for use at large solar zenith angles (SZAs) where they have a systematic low bia...

  12. Canopy Surface Reconstruction and Tropical Forest Parameters Prediction from Airborne Laser Scanner for Large Forest Area

    Science.gov (United States)

    Chen, Z.; Yang, Z.; Chen, Y.; Wang, C.; Qian, J.; Yang, Q.; Chen, X.; Lei, J.

    2017-10-01

    Canopy height model(CHM) and tree mean height are critical forestry parameters that many other parameters such as growth, carbon sequestration, standing timber volume, and biomass can be derived from. LiDAR is a new method used to rapidly estimate these parameters over large areas. The estimation of these parameters has been derived successfully from CHM. However, a number of challenges limit the accurate retrieval of tree height and crowns, especially in tropical forest area. In this study, an improved canopy estimation model is proposed based on dynamic moving window that applied on LiDAR point cloud data. DEM, DSM and CHM of large tropical forest area can be derived from LiDAR data effectively and efficiently.

  13. Surface passivity largely governs the bioaccessibility of nickel-based powder particles at human exposure conditions.

    Science.gov (United States)

    Hedberg, Yolanda S; Herting, Gunilla; Latvala, Siiri; Elihn, Karine; Karlsson, Hanna L; Odnevall Wallinder, Inger

    2016-11-01

    The European chemical framework REACH requires that hazards and risks posed by chemicals, including alloys and metals, are identified and proven safe for humans and the environment. Therefore, differences in bioaccessibility in terms of released metals in synthetic biological fluids (different pH (1.5-7.4) and composition) that are relevant for different human exposure routes (inhalation, ingestion, and dermal contact) have been assessed for powder particles of an alloy containing high levels of nickel (Inconel 718, 57 wt% nickel). This powder is compared with the bioaccessibility of two nickel-containing stainless steel powders (AISI 316L, 10-12% nickel) and with powders representing their main pure alloy constituents: two nickel metal powders (100% nickel), two iron metal powders and two chromium metal powders. X-ray photoelectron spectroscopy, microscopy, light scattering, and nitrogen absorption were employed for the particle and surface oxide characterization. Atomic absorption spectroscopy was used to quantify released amounts of metals in solution. Cytotoxicity (Alamar blue assay) and DNA damage (comet assay) of the Inconel powder were assessed following exposure of the human lung cell line A549, as well as its ability to generate reactive oxygen species (DCFH-DA assay). Despite its high nickel content, the Inconel alloy powder did not release any significant amounts of metals and did not induce any toxic response. It is concluded, that this is related to the high surface passivity of the Inconel powder governed by its chromium-rich surface oxide. Read-across from the pure metal constituents is hence not recommended either for this or any other passive alloy. Copyright © 2016 The Author(s). Published by Elsevier Inc. All rights reserved.

  14. Biofilm formation by Psychrobacter arcticus and the role of a large adhesin in attachment to surfaces.

    Science.gov (United States)

    Hinsa-Leasure, Shannon M; Koid, Cassandra; Tiedje, James M; Schultzhaus, Janna N

    2013-07-01

    Psychrobacter arcticus strain 273-4, an isolate from a Siberian permafrost core, is capable of forming biofilms when grown in minimal medium under laboratory conditions. Biofilms form at 4 to 22°C when acetate is supplied as the lone carbon source and with 1 to 7% sea salt. P. arcticus is also capable of colonizing quartz sand. Transposon mutagenesis identified a gene important for biofilm formation by P. arcticus. Four transposon mutants were mapped to a 20.1-kbp gene, which is predicted to encode a protein of 6,715 amino acids (Psyc_1601). We refer to this open reading frame as cat1, for cold attachment gene 1. The cat1 mutants are unable to form biofilms at levels equivalent to that of the wild type, and there is no impact on the planktonic growth characteristics of the strains, indicating a specific role in biofilm formation. Through time course studies of the static microtiter plate assay, we determined that cat1 mutants are unable to form biofilms equivalent to that of the wild type under all conditions tested. In flow cell experiments, cat1 mutants initially are unable to attach to the surface. Over time, however, they form microcolonies, an architecture very different from that produced by wild-type biofilms. Our results demonstrate that Cat1 is involved in the initial stages of bacterial attachment to surfaces.

  15. Spherical Torus Plasma Interactions with Large-area Liquid Lithium Surfaces in CDX-U

    International Nuclear Information System (INIS)

    Kaita, R.; Majeski, R.; Boaz, M.; Efthimion, P.; Jones, B.; Hoffman, D.; Kugel, H.; Menard, J.; Munsat, T.; Post-Zwicker, A.; Soukhanovskii, V.; Spaleta, J.; Taylor, G.; Timberlake, J.; Woolley, R.; Zakharov, L.; Finkenthal, M.; Stutman, D.; Antar, G.; Doerner, R.; Luckhardt, S.; Maingi, R.; Maiorano, M.; Smith, S.

    2002-01-01

    The Current Drive Experiment-Upgrade (CDX-U) device at the Princeton Plasma Physics Laboratory (PPPL) is a spherical torus (ST) dedicated to the exploration of liquid lithium as a potential solution to reactor first-wall problems such as heat load and erosion, neutron damage and activation, and tritium inventory and breeding. Initial lithium limiter experiments were conducted with a toroidally-local liquid lithium rail limiter (L3) from the University of California at San Diego. Spectroscopic measurements showed a clear reduction of impurities in plasmas with the L3, compared to discharges with a boron carbide limiter. The evidence for a reduction in recycling was less apparent, however. This may be attributable to the relatively small area in contact with the plasma, and the presence of high-recycling surfaces elsewhere in the vacuum chamber. This conclusion was tested in subsequent experiments with a fully toroidal lithium limiter that was installed above the floor of the vacuum vessel. The new limiter covered over ten times the area of the L3 facing the plasma. Experiments with the toroidal lithium limiter have recently begun. This paper describes the conditioning required to prepare the lithium surface for plasma operations, and effect of the toroidal liquid lithium limiter on discharge performance

  16. Spherical Torus Plasma Interactions with Large-area Liquid Lithium Surfaces in CDX-U

    Energy Technology Data Exchange (ETDEWEB)

    R. Kaita; R. Majeski; M. Boaz; P. Efthimion; B. Jones; D. Hoffman; H. Kugel; J. Menard; T. Munsat; A. Post-Zwicker; V. Soukhanovskii; J. Spaleta; G. Taylor; J. Timberlake; R. Woolley; L. Zakharov; M. Finkenthal; D. Stutman; G. Antar; R. Doerner; S. Luckhardt; R. Maingi; M. Maiorano; S. Smith

    2002-01-18

    The Current Drive Experiment-Upgrade (CDX-U) device at the Princeton Plasma Physics Laboratory (PPPL) is a spherical torus (ST) dedicated to the exploration of liquid lithium as a potential solution to reactor first-wall problems such as heat load and erosion, neutron damage and activation, and tritium inventory and breeding. Initial lithium limiter experiments were conducted with a toroidally-local liquid lithium rail limiter (L3) from the University of California at San Diego. Spectroscopic measurements showed a clear reduction of impurities in plasmas with the L3, compared to discharges with a boron carbide limiter. The evidence for a reduction in recycling was less apparent, however. This may be attributable to the relatively small area in contact with the plasma, and the presence of high-recycling surfaces elsewhere in the vacuum chamber. This conclusion was tested in subsequent experiments with a fully toroidal lithium limiter that was installed above the floor of the vacuum vessel. The new limiter covered over ten times the area of the L3 facing the plasma. Experiments with the toroidal lithium limiter have recently begun. This paper describes the conditioning required to prepare the lithium surface for plasma operations, and effect of the toroidal liquid lithium limiter on discharge performance.

  17. Assessment of Surface Radiation Dose Rate and Accumulation of Cadmium, Nickel and Lead in the Roadside Soils Along Bandar Pusat Jengka to Chenor Toll, Pahang

    International Nuclear Information System (INIS)

    Norihan Zainun Abiden; Nazree Ahmad; Junaidah Md Sani; Ahmad Saat; Ahmad Saat

    2015-01-01

    Studies have been carried out along the road of Bandar Pusat Jengka to Tol Chenor, Pahang to determine surface radiation dose rate and heavy metals concentration in the roadside soils as a result of transportation of mining wastes. The in situ surface radiation dose and concentration of Cd, Ni and Pb were studied and compared with the results obtained from an area with no transportation of mining wastes. The outcomes of this research were compared with the tolerable radiation dose and maximum allowable metal concentration in soils recommended by regulators. Result shows that, radiation dose at the surface was in a range of 0.146 μSv hr -1 to 0.467 μSv hr -1 with a mean value of 0.227 μSv hr -1 while radiation dose at 1 m above the ground was in a range of 0.101 μSv hr -1 to 0.322 μSv hr -1 with an average value of 0.151 μSv/ hr. Accumulation of Cd, Ni and Pb in soil samples at study areas yield an average concentration of 1.90±0.54 mg kg -1 , 61.45±14.71 mg kg -1 and 104.41±8.62 mg kg -1 respectively. The result indicates elevated doses of radiation which is above the recommended value. Meanwhile, the distribution of heavy metals in the roadside soils at the sampling areas noted a lower level of metal concentration than their background limit. The findings of this preliminary study indicates the importance of radiological and heavy metals studies on the side of preventing further dispersion and distribution of these toxicants in the environment besides monitoring and protecting the ecosystem balance for present and future generation. (author)

  18. Evaluation of surface radiation dose to the thyroid gland and the gonads during routine full-mouth intraoral periapical and maxillary occlusal radiography

    Directory of Open Access Journals (Sweden)

    Soheyl Sheikh

    2010-01-01

    Full Text Available Aim: The quantitative aspects of radiation doses to critical organs can help the dental professionals to take the necessary radiation protective measures as deemed necessary and can help the general public to allay radiation exposure fear in dental radiography, if any. Our study determines the surface radiation dose to thyroid and gonads in full-mouth intraoral periapical (IOPA and maxillary occlusal radiography.Materials and Methods: A total number of 120 subjects participated in the study. The surface radiation dose was estimated to the thyroid gland and the gonads in full-mouth IOPA radiography using 10 IOPA (E speed films and in maxillary occlusal radiography. The measurements were calculated using a digital pocket dosimeter (PD-4507.Results: The average dose at the thyroid gland level during full-mouth intraoral and maxillary occlusal radiography was estimated to be 10.93 mRads (1.093 Χ 10 -2 mGy and 0.4 mRads (4.0 Χ 10 -2 mGy, respectively. The average surface radiation dose at the gonadal region during a full mouth intraoral and maxillary occlusal radiography was estimated to be 1.5 mRads (1.5 Χ 10 -2 mGy and 0.15 mRads (1.5 Χ 10 -3 mGy, respectively. Conclusion: Our results suggest that although the radiation exposure doses to critical organs namely thyroid and gonads is within the safe limits still precautionary measures for these organs are advocated.

  19. Monte Carlo simulations of the secondary neutron ambient and effective dose equivalent rates from surface to suborbital altitudes and low Earth orbit.

    Science.gov (United States)

    El-Jaby, Samy; Richardson, Richard B

    2015-07-01

    Occupational exposures from ionizing radiation are currently regulated for airline travel (Earth orbit (∼300-400 km). Aircrew typically receive between 1 and 6 mSv of occupational dose annually, while aboard the International Space Station, the area radiation dose equivalent measured over just 168 days was 106 mSv at solar minimum conditions. It is anticipated that space tourism vehicles will reach suborbital altitudes of approximately 100 km and, therefore, the annual occupational dose to flight crew during repeated transits is expected to fall somewhere between those observed for aircrew and astronauts. Unfortunately, measurements of the radiation environment at the high altitudes reached by suborbital vehicles are sparse, and modelling efforts have been similarly limited. In this paper, preliminary MCNPX radiation transport code simulations are developed of the secondary neutron flux profile in air from surface altitudes up to low Earth orbit at solar minimum conditions and excluding the effects of spacecraft shielding. These secondary neutrons are produced by galactic cosmic radiation interacting with Earth's atmosphere and are among the sources of radiation that can pose a health risk. Associated estimates of the operational neutron ambient dose equivalent, used for radiation protection purposes, and the neutron effective dose equivalent that is typically used for estimates of stochastic health risks, are provided in air. Simulations show that the neutron radiation dose rates received at suborbital altitudes are comparable to those experienced by aircrew flying at 7 to 14 km. We also show that the total neutron dose rate tails off beyond the Pfotzer maximum on ascension from surface up to low Earth orbit. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  20. Big Jump of Record Warm Global Mean Surface Temperature in 2014-2016 Related to Unusually Large Oceanic Heat Releases

    Science.gov (United States)

    Yin, Jianjun; Overpeck, Jonathan; Peyser, Cheryl; Stouffer, Ronald

    2018-01-01

    A 0.24°C jump of record warm global mean surface temperature (GMST) over the past three consecutive record-breaking years (2014-2016) was highly unusual and largely a consequence of an El Niño that released unusually large amounts of ocean heat from the subsurface layer of the northwestern tropical Pacific. This heat had built up since the 1990s mainly due to greenhouse-gas (GHG) forcing and possible remote oceanic effects. Model simulations and projections suggest that the fundamental cause, and robust predictor of large record-breaking events of GMST in the 21st century, is GHG forcing rather than internal climate variability alone. Such events will increase in frequency, magnitude, and duration, as well as impact, in the future unless GHG forcing is reduced.

  1. Organ Doses and Effective Doses in Pediatric Radiography: Patient-Dose Survey in Finland

    Energy Technology Data Exchange (ETDEWEB)

    Kiljunen, T.; Tietaevaeinen, A.; Parviainen, T.; Viitala, A.; Kortesniemi, M. (Radiation Practices Regulation, Radiation and Nuclear Safety Authority, Helsinki (Finland))

    2009-01-15

    Background: Use of the effective dose in diagnostic radiology permits the radiation exposure of diverse diagnostic procedures to be quantified. Fundamental knowledge of patient doses enhances the implementation of the 'as low as reasonably achievable' (ALARA) principle. Purpose: To provide comparative information on pediatric examination protocols and patient doses in skull, sinus, chest, abdominal, and pelvic radiography examinations. Material and Methods: 24 Finnish hospitals were asked to register pediatric examination data, including patient information and examination parameters and specifications. The total number of examinations in the study was 1916 (1426 chest, 228 sinus, 96 abdominal, 94 skull, and 72 pelvic examinations). Entrance surface dose (ESD) and dose-area products (DAP) were calculated retrospectively or DAP meters were used. Organ doses and effective doses were determined using a Monte Carlo program (PCXMC). Results: There was considerable variation in examination protocols between different hospitals, indicating large variations in patient doses. Mean effective doses of different age groups ranged from 5 muSv to 14 muSv in skull and sinus examinations, from 25 muSv to 483 muSv in abdominal examinations, and from 6 muSv to 48 muSv in chest examinations. Conclusion: In chest and sinus examinations, the amount of data was extensive, allowing national pediatric diagnostic reference levels to be defined. Parameter selection in pediatric examination protocols should be harmonized in order to reduce patient doses and improve optimization

  2. Self-assembling of large ordered DNA arrays using superhydrophobic patterned surfaces

    International Nuclear Information System (INIS)

    Ciasca, G; Papi, M; Chiarpotto, M; Palmieri, V; De Spirito, M; Businaro, L; Notargiacomo, A; De Ninno, A; Carta, S; Giovine, E; Gerardino, A

    2013-01-01

    In this paper we present a simple and robust method to realize highly ordered arrays of stretched and suspended DNA molecules over the millimeter length scale. To this end we used an ad hoc designed superhydrophobic surface made of high aspect-ratio silicon pillars, where we deposited a droplet containing genomic DNA. A precise positioning of DNA strands was achieved by shaping the silicon pillars so that sharpened features resembling tips were included. Such features allowed us to accurately control the droplet de-wetting dynamics, pinning DNA strands in a well-defined position above pillars. The proposed technique has the potential to positively impact on the development of novel DNA chips for genetic analysis. (paper)

  3. Large-scale sea surface temperature variability from satellite and shipboard measurements

    Science.gov (United States)

    Bernstein, R. L.; Chelton, D. B.

    1985-01-01

    A series of satellite sea surface temperature intercomparison workshops were conducted under NASA sponsorship at the Jet Propulsion Laboratory. Three different satellite data sets were compared with each other, with routinely collected ship data, and with climatology, for the months of November 1979, December 1981, March 1982, and July 1982. The satellite and ship data were differenced against an accepted climatology to produce anomalies, which in turn were spatially and temporally averaged into two-degree latitude-longitude, one-month bins. Monthly statistics on the satellite and ship bin average temperatures yielded rms differences ranging from 0.58 to 1.37 C, and mean differences ranging from -0.48 to 0.72 C, varying substantially from month to month, and sensor to sensor.

  4. Effects of ground surface decontamination on the air radiation dose rate. Results of a decontamination trial at a playground lot in a Fukushima residential area

    International Nuclear Information System (INIS)

    Tagawa, Akihiro

    2012-01-01

    The Japan Atomic Energy Agency decontaminated schools, playgrounds, swimming pools, and houses in nonevacuated, less-contaminated areas in Fukushima for environmental restoration. A small, 150 m 2 playground lot in the residential area was chosen for decontamination demonstration, which used routinely available tools and commodities to carry out the work. The surfaces of playground lot equipment, such as swings, slides, and horizontal iron bars, were completely decontaminated by brushing with water and/or detergent. Side gutters around the playground lot were cleaned by removing the mud and then brushed and washed with a high-pressure water jet (7 MPa). The air dose rate at the playground lot was dominated by radiation from the ground surface and adjacent surroundings, such as apartments and rice fields. Two or three centimeters of the surface soil contaminated with cesium was removed manually with shovels, hoes, and other gardening tools. This significantly reduced the average air dose rate of the entire playground lot from 1.5 μSv/h before decontamination to 0.6 μSv/h. These results showed that ground surface decontamination can contribute measurably to the reduction in air dose rate in relatively small areas in residential areas. (author)

  5. Femtosecond laser fabrication of large-area periodic surface ripple structure on Si substrate

    International Nuclear Information System (INIS)

    Hong, L.; Rusli; Wang, X.C.; Zheng, H.Y.; Wang, H.; Yu, H.Y.

    2014-01-01

    In this paper, we report the fabrication of a large area uniformly distributed periodic nano-ripple structure on silicon substrate through the proper scanning of a line-shaped femtosecond laser beam. The fabricated nano-ripple structure has a periodicity of ∼600 nm and a ripple depth of ∼300 nm. The modulation depth is much deeper than the one previously reported. The developed structure is demonstrated to be able to substantially reduce light reflection due to the effective optical coupling between the incident sunlight with the nano-ripple structure and exhibit an absorption enhancement of ∼41% compared with planar silicon wafer. The physics underlying the formation of the nano-ripple structure is also discussed

  6. Rugosidade superficial do solo sob diferentes doses de resíduo de milho submetido à chuva simulada Soil surface roughness with different doses of corn residue submitted to simulated rainfall

    Directory of Open Access Journals (Sweden)

    Ildegardis Bertol

    2007-01-01

    Full Text Available O objetivo deste trabalho foi avaliar a rugosidade e a tortuosidade da superfície do solo, preparado com diferentes doses de resíduo cultural de milho, e relacioná-las com o volume de chuva simulada. Em um Cambissolo, em La Coruña, Espanha, em agosto de 2005, avaliou-se a rugosidade superficial, no preparo mínimo sob chuva simulada, com as doses de 0, 2, 4, 6 e 8 t ha-1 de resíduo de milho picado e semi-incorporado ao solo. Aplicaram-se oito testes de chuva simulada, com 65 mm h-1 e 60 min cada um. A rugosidade e a tortuosidade, ao acaso, foram menores do que na condição linear e, as desta condição foram menores do que na condição original. A redução da rugosidade e da tortuosidade, em decorrência das chuvas, diminuiu com o aumento da dose de resíduo de milho. A rugosidade superficial foi mais fortemente influenciada quando se eliminou o efeito da declividade do terreno do que quando se eliminaram, simultaneamente, os efeitos da declividade e das marcas de preparo do solo para o seu cálculo.The objective of this work was to determine the surface roughness and the tortuosity of the soil tilled with different doses of corn residues, and to relate them to simulated rainfall volume. In an Inceptisol, in La Coruña, Spain, in August of 2005, the surface roughness and tortuosity were evaluated in the minimum soil tillage system under simulated rain, with the doses 0, 2, 4, 6, and 8 t ha-1 of corn residues semi-incorporated to the soil for manual tillage. Eight tests of simulated rain were applied, with 65 mm h-1 and 60 min each one. The surface roughness and tortuosity were determined before the application of the residue, immediately after the soil tillage and immediately after the 1st, 2nd, 4th, 6th and 8th tests of the rain. The reduction of the roughness and of the tortuosity, due to rain, decreased with the increase of corn residues doses. The superficial roughness was more strongly influenced, when the effect of land steepness

  7. Surface stress and large-scale self-organization at organic-metal interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Pollinger, Florian

    2009-01-22

    The role of elastic interactions, particularly for the self-organized formation of periodically faceted interfaces, was investigated in this thesis for archetype organic-metal interfaces. The cantilever bending technique was applied to study the change of surface stress upon formation of the interface between 3,4,9,10-perylene-tetracarboxylic-dianhydride (PTCDA) and Ag(111). The main focus of this work was on the investigation of the formation of the long-range ordered, self-organized faceted PTCDA/Ag(10 8 7) interface. Reciprocal space maps of this interface were recorded both by spot profile analysis low energy electron diffraction (SPA-LEED) and low energy electron microscopy (LEEM) in selected area LEED mode. Complementary to the reciprocal data, also microscopic real-space LEEM data were used to characterize the morphology of this interface. Six different facet faces ((111), (532), (743), (954), (13 9 5), and (542)) were observed for the preparation path of molecular adsorption on the substrate kept at 550 K. Facet-sensitive dark-field LEEM localized these facets to grow in homogeneous areas of microscopic extensions. The temperature-dependence of the interface formation was studied in a range between 418 K and 612 K in order to learn more about the kinetics of the process. Additional steeper facets of 27 inclination with respect to the (111) surface were observed in the low temperature regime. Furthermore, using facet-sensitive dark-field LEEM, spatial and size distributions of specific facets were studied for the different temperatures. Moreover, the facet dimensions were statistically analyzed. The total island size of the facets follows an exponential distribution, indicating a random growth mode in absence of any mutual facet interactions. While the length distribution of the facets also follows an exponential distribution, the width distribution is peaked, reflecting the high degree of lateral order. This anisotropy is temperature-dependent and occurs

  8. SU-E-T-230: Creating a Large Number of Focused Beams with Variable Patient Head Tilt to Improve Dose Fall-Off for Brain Radiosurgery

    International Nuclear Information System (INIS)

    Chiu, J; Ma, L

    2015-01-01

    Purpose: To develop a treatment delivery and planning strategy by increasing the number of beams to minimize dose to brain tissue surrounding a target, while maximizing dose coverage to the target. Methods: We analyzed 14 different treatment plans via Leksell PFX and 4C. For standardization, single tumor cases were chosen. Original treatment plans were compared with two optimized plans. The number of beams was increased in treatment plans by varying tilt angles of the patient head, while maintaining original isocenter and the beam positions in the x-, y- and z-axes, collimator size, and beam blocking. PFX optimized plans increased beam numbers with three pre-set tilt angles, 70, 90, 110, and 4C optimized plans increased beam numbers with tilt angles increasing arbitrarily from range of 30 to 150 degrees. Optimized treatment plans were compared dosimetrically with original treatment plans. Results: Comparing total normal tissue isodose volumes between original and optimized plans, the low-level percentage isodose volumes decreased in all plans. Despite the addition of multiple beams up to a factor of 25, beam-on times for 1 tilt angle versus 3 or more tilt angles were comparable (<1 min.). In 64% (9/14) of the studied cases, the volume percentage decrease by >5%, with the highest value reaching 19%. The addition of more tilt angles correlates to a greater decrease in normal brain irradiated volume. Selectivity and coverage for original and optimized plans remained comparable. Conclusion: Adding large number of additional focused beams with variable patient head tilt shows improvement for dose fall-off for brain radiosurgery. The study demonstrates technical feasibility of adding beams to decrease target volume

  9. Significance of tumor size and radiation dose to local control in stage I-III diffuse large cell lymphoma treated with CHOP-Bleo and radiation

    International Nuclear Information System (INIS)

    Fuller, Lillian M.; Krasin, Matthew J.; Velasquez, William S.; Allen, Pamela K.; McLaughlin, Peter; Rodriguez, M. Alma; Hagemeister, Fredrick B.; Swan, Forrest; Cabanillas, Fernando; Palmer, Judy L.; Cox, James D.

    1995-01-01

    Purpose: The purpose of this study was to evaluate the possible effect of adjunctive involved field (IF) radiotherapy on long-term local control for patients with Ann Arbor Stage I-III diffuse large cell lymphoma (DLCL) who achieved a complete remission on a combined modality program which included cyclophosphamide, doxorubicin, vincristine, prednisone, and Bleomycin (CHOP-Bleo). Methods and Materials: One hundred and ninety patients with Ann Arbor Stage I-III DLCL were treated with CHOP-Bleo and radiotherapy. Analyses were undertaken to determine (a) response to treatment according to stage, extent of maximum local disease, and irradiation dose either < 40 Gy or ≥ 40 Gy and (b) relapse patterns. Results: A complete remission (CR) was achieved in 162 patients. Among patients who achieved a CR, local control was better for those who received tumor doses of ≥ 40 Gy (97%) than for those who received < 40 Gy (83%) (p = 0.002.) Among those with extensive local disease, the corresponding control rates were 88% and 71%, respectively. A study of distant relapse patterns following a CR showed that the first relapse usually involved an extranodal site. Conclusion: Radiotherapy was an effective adjunctive treatment to CHOP-Bleo for patients with stage I-III DLCL who achieved a CR. Patterns of relapse suggested that total nodal irradiation (TNI) possibly could have benefited a small subset of patients

  10. Modeling detailed hydro-meteorological surfaces and runoff response in large diverse watersheds

    International Nuclear Information System (INIS)

    Byrne, J.; Kienzle, S.W.; MacDonald, R.J.

    2008-01-01

    An understanding of local variability in climatic conditions over complex terrain is imperative to making accurate assessments of impacts from climate change on fresh water ecosystems (Daly, 2006). The derivation of representative spatial data in diverse environments poses a significant challenge to the modelling community. This presentation describes the current status of a long term ongoing hydro-climate model development program. We are developing a gridded hydroclimate dataset for diverse watersheds using SimGrid (Larson, 2008; Lapp et al., 2005; Sheppard, 1996), a model that applies the Mountain Climate Model (MTCLIM; Hungerford et al., 1989) to simulate hydro-climatic conditions over diverse terrain. The model uses GIS based terrain categories (TC) classified by slope, aspect, elevation, and soil water storage. SimGrid provides daily estimates of solar radiation, air temperature, relative humidity, precipitation, snowpack and soil water storage over space. Earlier versions of the model have been applied in the St. Mary (Larson, 2008) and upper Oldman basins (Lapp et al., 2005), giving realistic estimates of hydro-climatic variables. The current study demonstrates improvements to the estimation of temperature, precipitation, snowpack, soil water storage and runoff from the basin. Soil water storage data for the upper drainage were derived with GIS and included in SimGrid to estimate soil water flux over the time period. These changes help improve the estimation of spatial climatic variability over the basin while accounting for topographical influence. In further work we will apply spatial hydro-climatic surfaces from the SimGrid model to assess the hydrologic response to environmental change for watersheds in Canada and beyond. (author)

  11. Randomized Trial Comparing R-CHOP Versus High-Dose Sequential Chemotherapy in High-Risk Patients With Diffuse Large B-Cell Lymphomas.

    Science.gov (United States)

    Cortelazzo, Sergio; Tarella, Corrado; Gianni, Alessandro Massimo; Ladetto, Marco; Barbui, Anna Maria; Rossi, Andrea; Gritti, Giuseppe; Corradini, Paolo; Di Nicola, Massimo; Patti, Caterina; Mulé, Antonino; Zanni, Manuela; Zoli, Valerio; Billio, Atto; Piccin, Andrea; Negri, Giovanni; Castellino, Claudia; Di Raimondo, Francesco; Ferreri, Andrés J M; Benedetti, Fabio; La Nasa, Giorgio; Gini, Guido; Trentin, Livio; Frezzato, Maurizio; Flenghi, Leonardo; Falorio, Simona; Chilosi, Marco; Bruna, Riccardo; Tabanelli, Valentina; Pileri, Stefano; Masciulli, Arianna; Delaini, Federica; Boschini, Cristina; Rambaldi, Alessandro

    2016-11-20

    Purpose The benefit of high-dose chemotherapy with autologous stem-cell transplantation (ASCT) as first-line treatment in patients with diffuse large B-cell lymphomas is still a matter of debate. To address this point, we designed a randomized phase III trial to compare rituximab plus cyclophosphamide, doxorubicin, vincristine, and prednisone (R-CHOP)-14 (eight cycles) with rituximab plus high-dose sequential chemotherapy (R-HDS) with ASCT. Patients and Methods From June 2005 to June 2011, 246 high-risk patients with a high-intermediate (56%) or high (44%) International Prognostic Index score were randomly assigned to the R-CHOP or R-HDS arm, and 235 were analyzed by intent to treat. The primary efficacy end point of the study was 3-year event-free survival, and results were analyzed on an intent-to-treat basis. Results Clinical response (complete response, 78% v 76%; partial response, 5% v 9%) and failures (no response, 15% v 11%; and early treatment-related mortality, 2% v 3%) were similar after R-CHOP versus R-HDS, respectively. After a median follow-up of 5 years, the 3-year event-free survival was 62% versus 65% ( P = .83). At 3 years, compared with the R-CHOP arm, the R-HDS arm had better disease-free survival (79% v 91%, respectively; P = .034), but this subsequently vanished because of late-occurring treatment-related deaths. No difference was detected in terms of progression-free survival (65% v 75%, respectively; P = .12), or overall survival (74% v 77%, respectively; P = .64). Significantly higher hematologic toxicity ( P < .001) and more infectious complications ( P < .001) were observed in the R-HDS arm. Conclusion In this study, front-line intensive R-HDS chemotherapy with ASCT did not improve the outcome of high-risk patients with diffuse large B-cell lymphomas.

  12. TH-C-12A-10: Surface Dose Enhancement Using Novel Hybrid Electron and Photon Low-Z Therapy Beams: Monte Carlo Simulation

    International Nuclear Information System (INIS)

    Parsons, C; Parsons, D; Robar, J; Kelly, R

    2014-01-01

    Purpose: The introduction of the TrueBeam linac platform provides access to an in-air target assembly making it possible to apply novel treatments using multiple target designs. One such novel treatment uses multiple low-Z targets to enhance surface dose replacing the use of synthetic tissue equivalent material (bolus). This treatment technique will decrease the common dosimetric and set up errors prevalent in using physical treatment accessories like bolus. The groundwork for a novel treatment beam used to enhance surface dose to within 80-100% of the dose at dmax by utilizing low-Z (Carbon) targets of various percent CSDA range thickness operated at 2.5–4 MeV used in conjunction with a clinical 6 MV beam is presented herein. Methods: A standard Monte Carlo model of a Varian Clinac accelerator was developed to manufacturers specifications. Simulations were performed using Be, C, AL, and C, as potential low-Z targets, placed in the secondary target position. The results determined C to be the target material of choice. Simulations of 15, 30 and 60% CSDA range C beams were propagated through slab phantoms. The resulting PDDs were weighted and combined with a standard 6 MV treatment beam. Versions of the experimental targets were installed into a 2100C Clinac and the models were validated. Results: Carbon was shown to be the low-Z material of choice for this project. Using combinations of 15, 30, 60% CSDA beams operated at 2.5 and 4 MeV in combination with a standard 6 MV treatment beam the surface dose was shown to be enhanced to within 80–100% the dose at dmax. Conclusion: The modeled low-Z beams were successfully validated using machined versions of the targets. Water phantom measurements and slab phantom simulations show excellent correlation. Patient simulations are now underway to compare the use of bolus with the proposed novel beams. NSERC

  13. Metal-Free Counter Electrode for Efficient Dye-Sensitized Solar Cells through High Surface Area and Large Porous Carbon

    Directory of Open Access Journals (Sweden)

    Pavuluri Srinivasu

    2011-01-01

    Full Text Available Highly efficient, large mesoporous carbon is fabricated as a metal-free counter electrode for dye-sensitized solar cells. The mesoporous carbon shows very high energy conversion efficiency of 7.1% compared with activated carbon. The mesoporous carbon is prepared and characterized by nitrogen adsorption, scanning electron microscopy (SEM, and transmission electron microscopy (TEM. The nitrogen adsorption data reveals that the material possesses BET specific surface area ca.1300 m2/g and pore diameter 4.4 nm. Hexagonal rod-like morphology and ordered pore structure of mesoporous carbon are confirmed by electron microscopy data. The better performance of this carbon material is greatly benefited from its ordered interconnected mesoporous structure and high surface area.

  14. [Measurement of effective energy and entrance surface dose using fluorescent glass dosimeter in interventional radiology procedures: make of half-value layer measurement instrument and IVR-phantom].

    Science.gov (United States)

    Iida, Hiroji; Noto, Kimiya; Takata, Tadanori; Chabatake, Mitsuhiro; Yamamoto, Tomoyuki

    2010-05-20

    In interventional radiology (IVR) procedures, automatic brightness control (ABC) is helpful in maintaining good image quality by adjusting kV and/or mA based on the subject's thickness. However, it was difficult to measure effective energy using half-value layer (HVL). We investigated the usefulness of measuring effective energy and entrance surface dose using a fluorescent glass dosimeter in IVR procedures, and we made an HVL folder and IVR-phantom for that purpose. Effective energy measured using the HVL folder correlated well with reference ionization dosimeter (y=0.992x, r=0.963). The result indicated that the present method using an HVL folder and IVR-phantom provides accurate measurements of effective energy and entrance surface dose in IVR procedures. In conclusion, the present measurement method may be useful for quality control of IVR equipment. In addition, the development of this measurement technique may be useful for comparisons of exposure levels in different hospitals.

  15. Martian Meteorology: Determination of Large Scale Weather Patterns from Surface Measurements

    Science.gov (United States)

    Murphy, James R.; Haberle, Robert M.; Bridger, Alison F. C.

    1998-01-01

    We employed numerical modelling of the martian atmosphere, and our expertise in understanding martian atmospheric processes, to better understand the coupling between lower and upper atmosphere processes. One practical application of this work has been our involvement with the ongoing atmospheric aerobraking which the Mars Global Surveyor (MGS) spacecraft is currently undergoing at Mars. Dr. Murphy is currently a member of the Mars Global Surveyor (MGS) Aerobraking Atmospheric Advisory Group (AAG). He was asked to participate in this activity based upon his knowledge of martian atmospheric dynamical processes. Aerobraking is a process whereby a spacecraft, in an elliptical orbit, passes through the upper layers of the atmosphere (in this instance Mars). This passage through the atmosphere 'drags'upon the spacecraft, gradually reducing its orbital velocity. This has the effect, over time, of converting the elliptical orbit to a circular orbit, which is the desired mapping orbit for MGS. Carrying out aerobraking eliminates the need for carrying large amounts of fuel on the spacecraft to execute an engine burn to achieve the desired orbit. Eliminating the mass of the fuel reduces the cost of launch. Damage to one of MGS's solar panels shortly after launch has resulted in a less aggressive extended in time aerobraking phase which will not end until March, 1999. Phase I extended from Sept. 1997 through March 1998. During this time period, Dr. Murphy participated almost daily in the AAG meetings, and beginning in December 1997 lead the meeting several times per week. The leader of each of the daily AAG meetings took the results of that meeting (current state of the atmosphere, identification of any time trends or spatial patterns in upper atmosphere densities, etc.) forward to the Aerobraking Planning Group (APG) meeting, at which time the decision was made to not change MGS orbit, to lower the orbit to reach higher densities (greater 'drag'), or raise the orbit to avoid

  16. Recent Successes and Remaining Challenges in Predicting Phosphorus Loading to Surface Waters at Large Scales

    Science.gov (United States)

    Harrison, J.; Metson, G.; Beusen, A.

    2017-12-01

    Over the past century humans have greatly accelerated phosphorus (P) flows from land to aquatic ecosystems, causing eutrophication and associated effects such as harmful algal blooms and hypoxia. Effectively addressing this challenge requires understanding geographic and temporal distribution of aquatic P loading, knowledge of major controls on P loading, and the relative importance of various potential P sources. The Global (N)utrient (E)xport from (W)ater(S)heds) NEWS model and recent improvements and extensions of this modeling system can be used to generate this understanding. This presentation will focus on insights global NEWS models grant into past, present, and potential future P sources and sinks, with a focus on the world's large rivers. Early results suggest: 1) that while aquatic P loading is globally dominated by particulate forms, dissolved P can be locally dominant; 2) that P loading has increased substantially at the global scale, but unevenly between world regions, with hotspots in South and East Asia; 3) that P loading is likely to continue to increase globally, but decrease in certain regions that are actively pursuing proactive P management; and 4) that point sources, especially in urban centers, play an important (even dominant) role in determining loads of dissolved inorganic P. Despite these insights, substantial unexplained variance remains when model predictions and measurements are compared at global and regional scales, for example within the U.S. Disagreements between model predictions and measurements suggest opportunities for model improvement. In particular, explicit inclusion of soil characteristics and the concept of temporal P legacies in future iterations of NEWS (and other) models may help improve correspondence between models and measurements.

  17. The role of reservoir storage in large-scale surface water availability analysis for Europe

    Science.gov (United States)

    Garrote, L. M.; Granados, A.; Martin-Carrasco, F.; Iglesias, A.

    2017-12-01

    A regional assessment of current and future water availability in Europe is presented in this study. The assessment was made using the Water Availability and Adaptation Policy Analysis (WAAPA) model. The model was built on the river network derived from the Hydro1K digital elevation maps, including all major river basins of Europe. Reservoir storage volume was taken from the World Register of Dams of ICOLD, including all dams with storage capacity over 5 hm3. Potential Water Availability is defined as the maximum amount of water that could be supplied at a certain point of the river network to satisfy a regular demand under pre-specified reliability requirements. Water availability is the combined result of hydrological processes, which determine streamflow in natural conditions, and human intervention, which determines the available hydraulic infrastructure to manage water and establishes water supply conditions through operating rules. The WAAPA algorithm estimates the maximum demand that can be supplied at every node of the river network accounting for the regulation capacity of reservoirs under different management scenarios. The model was run for a set of hydrologic scenarios taken from the Inter-Sectoral Impact Model Intercomparison Project (ISIMIP), where the PCRGLOBWB hydrological model was forced with results from five global climate models. Model results allow the estimation of potential water stress by comparing water availability to projections of water abstractions along the river network under different management alternatives. The set of sensitivity analyses performed showed the effect of policy alternatives on water availability and highlighted the large uncertainties linked to hydrological and anthropological processes.

  18. The Response of African Land Surface Phenology to Large Scale Climate Oscillations

    Science.gov (United States)

    Brown, Molly E.; de Beurs, Kirsten; Vrieling, Anton

    2010-01-01

    Variations in agricultural production due to rainfall and temperature fluctuations are a primary cause of food insecurity on the African continent. Analysis of changes in phenology can provide quantitative information on the effect of climate variability on growing seasons in agricultural regions. Using a robust statistical methodology, we describe the relationship between phenology metrics derived from the 26 year AVHRR NDVI record and the North Atlantic Oscillation index (NAO), the Indian Ocean Dipole (IOD), the Pacific Decadal Oscillation (PDO), and the Multivariate ENSO Index (MEI). We map the most significant positive and negative correlation for the four climate indices in Eastern, Western and Southern Africa between two phenological metrics and the climate indices. Our objective is to provide evidence of whether climate variability captured in the four indices has had a significant impact on the vegetative productivity of Africa during the past quarter century. We found that the start of season and cumulative NDVI were significantly affected by large scale variations in climate. The particular climate index and the timing showing highest correlation depended heavily on the region examined. In Western Africa the cumulative NDVI correlates with PDO in September-November. In Eastern Africa the start of the June-October season strongly correlates with PDO in March-May, while the PDO in December-February correlates with the start of the February-June season. The cumulative NDVI over this last season relates to the MEI of March-May. For Southern Africa, high correlations exist between SOS and NAO of September-November, and cumulative NDVI and MEI of March-May. The research shows that climate indices can be used to anticipate late start and variable vigor in the growing season of sensitive agricultural regions in Africa.

  19. Photocurrent enhancement by surface plasmon resonance of gold nanoparticles in spray deposited large area dye sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Chander, Nikhil; Singh, Puneet [Photovoltaic Laboratory, Centre for Energy Studies, Indian Institute of Technology Delhi, New Delhi 110016 (India); Khan, A.F. [Department of Electronics and Information Technology, Ministry of Communications and Information Technology, Government of India, New Delhi 110003 (India); Dutta, Viresh [Photovoltaic Laboratory, Centre for Energy Studies, Indian Institute of Technology Delhi, New Delhi 110016 (India); Komarala, Vamsi K., E-mail: vamsi@ces.iitd.ac.in [Photovoltaic Laboratory, Centre for Energy Studies, Indian Institute of Technology Delhi, New Delhi 110016 (India)

    2014-10-01

    A facile method for fabricating large area TiO{sub 2} and TiO{sub 2}–Au nanocomposite films for dye sensitized solar cells (DSSCs) is presented using a spray technique. Pre-synthesized gold nanoparticles (Au NPs) were sprayed together with the TiO{sub 2} NPs and composite films with brilliant coloration due to surface plasmon resonances of Au NPs were prepared. Composite films containing ∼ 15 nm sized Au NPs exhibited enhanced absorption in the visible region of the electromagnetic spectrum. DSSCs with a large area of ∼ 4.5 cm{sup 2} were fabricated and a photocurrent enhancement of ∼ 10% was obtained for plasmonic DSSC containing 0.3 wt.% of ∼ 15 nm Au NPs. Incident photon to current conversion efficiency data conclusively showed enhanced currents in the visible region of the polychromatic spectrum arising due to plasmon enhanced near-field effects of Au NPs around the absorbing dye molecules. - Highlights: • Preparation of TiO{sub 2} and TiO{sub 2}–Au films with a large area of ∼ 7.5 cm{sup 2} by a spray technique • An efficiency of ∼ 4.5% achieved by the large area plasmonic DSSC • Photocurrent enhancement due to SPR effects of gold NPs observed • Comparison of the spray and conventional doctor blade methods in DSSC performance • Demonstration of technological feasibility and versatility of a simple spray process.

  20. Analysis of operators' surface doses in the common endovascular and on-vascular interventional diagnosis and treatment

    International Nuclear Information System (INIS)

    Zhang Lin; Zhu Jianguo; Min Nan; Lu Feng

    2011-01-01

    Objective: To contrast the level of radiation doses of Lead protective clothing both inside and outside in different parts of the body of the first and second operators and touring nurse in common endovascular and non-vascular interventional diagnosis and treatment. Methods: We choose the common endovascular interventional diagnosis and treatment in the head, thorax, abdomen, such as Cerebral angiography, Coronary angiography, Transcatheter arterial chemoembolization and non-vascular interventional diagnosis and treatment such as Endoscopic Retrograde Cholangio-Pancreatography and Percutaneous transhepatic cholangial drainage as experiment objects. Put the thermoluminescence dosimeter on the different spots of Lead protective clothing of subjects (Inside and outside the lead cap and the lead collar, inside and outside of the lead protective clothing in chest and abdomen, left upper arm outside of lead protective clothing, back of the left hand) and X-ray machine outgoing port when the operation was going on. After that, measure the thermoluminescence dosimeter, calculate and analyze exposure doses inside and outside of the lead protective clothing. Results: The skin doses of operators in different types of interventional diagnosis and treatment are listed in Table 1to Table 4; exposure doses of touring nurses are very low; the doses of X-ray machine outgoing port are mostly over the measuring range. Conclusion: The protection of Lead clothes plays a significant role in these two types of interventional diagnosis and treatment based on the conclusion that the dose of inside of Lead clothes is less than that of outside. We should enhance the operators' protection and administration in the process of intervention and arise the conscious of self-protection, to avoid the unnecessary radiation exposure. (authors)

  1. Multi-Annual Climate Predictions for Fisheries: An Assessment of Skill of Sea Surface Temperature Forecasts for Large Marine Ecosystems

    Directory of Open Access Journals (Sweden)

    Desiree Tommasi

    2017-06-01

    Full Text Available Decisions made by fishers and fisheries managers are informed by climate and fisheries observations that now often span more than 50 years. Multi-annual climate forecasts could further inform such decisions if they were skillful in predicting future conditions relative to the 50-year scope of past variability. We demonstrate that an existing multi-annual prediction system skillfully forecasts the probability of next year, the next 1–3 years, and the next 1–10 years being warmer or cooler than the 50-year average at the surface in coastal ecosystems. Probabilistic forecasts of upper and lower seas surface temperature (SST terciles over the next 3 or 10 years from the GFDL CM 2.1 10-member ensemble global prediction system showed significant improvements in skill over the use of a 50-year climatology for most Large Marine Ecosystems (LMEs in the North Atlantic, the western Pacific, and Indian oceans. Through a comparison of the forecast skill of initialized and uninitialized hindcasts, we demonstrate that this skill is largely due to the predictable signature of radiative forcing changes over the 50-year timescale rather than prediction of evolving modes of climate variability. North Atlantic LMEs stood out as the only coastal regions where initialization significantly contributed to SST prediction skill at the 1 to 10 year scale.

  2. Low-cost and large-scale flexible SERS-cotton fabric as a wipe substrate for surface trace analysis

    Science.gov (United States)

    Chen, Yanmin; Ge, Fengyan; Guang, Shanyi; Cai, Zaisheng

    2018-04-01

    The large-scale surface enhanced Raman scattering (SERS) cotton fabrics were fabricated based on traditional woven ones using a dyeing-like method of vat dyes, where silver nanoparticles (Ag NPs) were in-situ synthesized by 'dipping-reducing-drying' process. By controlling the concentration of AgNO3 solution, the optimal SERS cotton fabric was obtained, which had a homogeneous close packing of Ag NPs. The SERS cotton fabric was employed to detect p-Aminothiophenol (PATP). It was found that the new fabric possessed excellent reproducibility (about 20%), long-term stability (about 57 days) and high SERS sensitivity with a detected concentration as low as 10-12 M. Furthermore, owing to the excellent mechanical flexibility and good absorption ability, the SERS cotton fabric was employed to detect carbaryl on the surface of an apple by simply swabbing, which showed great potential in fast trace analysis. More importantly, this study may realize large-scale production with low cost by a traditional cotton fabric.

  3. Dose-response relationship of tryptophan with large neutral amino acids, and its impact on physiological responses in the chick model.

    Science.gov (United States)

    Bello, Alhassan Usman; Idrus, Zulkifli; Meng, Goh Yong; Narayan, Edward J; Farjam, Abdoreza Soleimani

    2018-05-01

    Tryptophan (Trp) has been associated with the regulation of several behavioral and physiological processes, through stimulation of serotonergic activity. Tryptophan utilization at the metabolic level is influenced by the competitive carrier system it shares with large neutral amino acids (LNAA). This study was carried out using meat-type chicken as a model, to investigate the dose response effects of Trp/LNAA on fear response (tonic immobility; TI) and hormonal responses, including corticosterone (CORT), serotonin (5-HT), triiodothyronine (T 3 ) and thyroxine (T 4 ). A total of 12 cages (48 birds) were assigned to each of the six experimental groups at 29-42 days of age. Experimental diets were formulated to have incremental levels of Trp/LNAA (0.025, 0.030, 0.035, 0.040, 0.045, and 0.050). The results revealed that, Trp/NAA had no significant effect on growth performance and TI of the birds. However, elevation of Trp/LNAA was concurred with a linear reduction in CORT (P < .0001, r 2  = 0.819) and linear increases in 5-HT (P < .0001, r 2  = 0.945), T 3 (P = .0003, r 2  = 0.403) and T 4 (P < .0001, r 2  = 0.937) levels. In conclusion, the results from the current study demonstrated that, although incremental levels of Trp/LNAA did not affect bird growth performance or fearfulness, it increased 5-HT, T 3 and T 4, and decreased CORT levels in a linear dose-dependent manner. Manipulation of Trp feeding levels could be applied to manage stressful conditions in birds. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Uncertainties of Large-Scale Forcing Caused by Surface Turbulence Flux Measurements and the Impacts on Cloud Simulations at the ARM SGP Site

    Science.gov (United States)

    Tang, S.; Xie, S.; Tang, Q.; Zhang, Y.

    2017-12-01

    Two types of instruments, the eddy correlation flux measurement system (ECOR) and the energy balance Bowen ratio system (EBBR), are used at the Atmospheric Radiation Measurement (ARM) program Southern Great Plains (SGP) site to measure surface latent and sensible fluxes. ECOR and EBBR typically sample different land surface types, and the domain-mean surface fluxes derived from ECOR and EBBR are not always consistent. The uncertainties of the surface fluxes will have impacts on the derived large-scale forcing data and further affect the simulations of single-column models (SCM), cloud-resolving models (CRM) and large-eddy simulation models (LES), especially for the shallow-cumulus clouds which are mainly driven by surface forcing. This study aims to quantify the uncertainties of the large-scale forcing caused by surface turbulence flux measurements and investigate the impacts on cloud simulations using long-term observations from the ARM SGP site.

  5. Age-specific effective doses for pediatric MSCT examinations at a large children's hospital using DLP conversion coefficients: a simple estimation method

    International Nuclear Information System (INIS)

    Thomas, Karen E.; Wang, Bo

    2008-01-01

    There is a need for an easily accessible method for effective dose estimation in pediatric CT. To estimate effective doses for a variety of pediatric neurological and body CT examinations in five age groups using recently published age- and region-specific dose length product (DLP) to effective dose conversion coefficients. A retrospective review was performed of 1,431 consecutive CT scans over a 12-week period using age- and weight-adjusted CT protocols. Age- and region-specific DLP to effective dose conversion coefficients were applied to console-displayed DLP data. Effective dose estimates for single-phase head CT scans in neonatal, and 1-, 5-, 10- and 15-year-old age groups were 4.2, 3.6, 2.4, 2.0 and 1.4 mSv, respectively. For abdomen/pelvis CT scans the corresponding effective doses were 13.1, 11.1, 8.4, 8.9 and 5.9 mSv. The range of pediatric CT effective doses is wide, from ultralow dose protocols (<1 mSv) to extended-coverage body examinations (10-15 mSv). Age- and region-specific pediatric DLP to effective dose conversion coefficients provide an accessible and user-friendly method for estimating pediatric CT effective doses that is available to radiologists working without medical physics support. (orig.)

  6. Prevalence of anti-hepatitis B surface antibodies among children and adolescents vaccinated in infancy and effect of booster dose administered within a pilot study.

    Science.gov (United States)

    Bassal, R; Markovich, M P; Weil, M; Shinar, E; Carmeli, Y; Dan, M; Sofer, D; Mendelson, E; Cohen, D; Shohat, T

    2017-10-01

    We determined the prevalence of anti-hepatitis B surface antibodies (anti-HBs) among children and adolescents vaccinated for hepatitis B virus in infancy as part of the routine vaccination programme. A representative serum sample of the Israeli population age 0-19 was tested. In a separate pilot study, a booster dose of hepatitis B vaccine was administered to 31 candidates for national service, who were fully vaccinated in infancy and tested negative for hepatitis B surface antibodies at age 17-19 years and anti-HBs antibodies were assessed 8 weeks later. Of the 1273 samples tested, 631 (49·6%) were positive to anti-HBs antibodies. Seropositivity rates were 89·5% among infants aged 6-12 months and declined significantly with age to 20·7% at age 19 years. No differences in seropositivity rates were observed between Jews and Arabs, males and females and those born in Israel and in other countries. Seroconversion rate among the 31 individuals who received a booster dose was 90·3% (95% CI: 75·1-96·6%). We recommend a booster dose for healthcare personnel before starting to work at the health care facility.

  7. Survey of Gamma Dose and Radon Exhalation Rate from Soil Surface of High Background Natural Radiation Areas in Ramsar, Iran

    Directory of Open Access Journals (Sweden)

    Rouhollah Dehghani

    2013-09-01

    Full Text Available Background: Radon is a radioactive gas and the second leading cause of death due to lung cancer after smoking. Ramsar is known for having the highest levels of natural background radiation on earth. Materials and Methods: In this research study, 50 stations of high radioactivity areas of Ramsar were selected in warm season of the year. Then gamma dose and radon exhalation rate were measured.Results: Results showed that gamma dose and radon exhalation rate were in the range of 51-7100 nSv/hr and 9-15370 mBq/m2s, respectively.Conclusion: Compare to the worldwide average 16 mBq/m2s, estimated average annual effective of Radon exhalation rate in the study area is too high.

  8. Role of carbon impurities on the surface morphology evolution of tungsten under high dose helium ion irradiation

    International Nuclear Information System (INIS)

    Al-Ajlony, A.; Tripathi, J.K.; Hassanein, A.

    2015-01-01

    The effect of carbon impurities on the surface evolution (e.g., fuzz formation) of tungsten (W) surface during 300 eV He ions irradiation was studied. Several tungsten samples were irradiated by He ion beam with a various carbon ions percentage. The presence of minute carbon contamination within the He ion beam was found to be effective in preventing the fuzz formation. At higher carbon concentration, the W surface was found to be fully covered with a thick graphitic layer on the top of tungsten carbide (WC) layer that cover the sample surface. Lowering the ion beam carbon percentage was effective in a significant reduction in the thickness of the surface graphite layer. Under these conditions the W surface was also found to be immune for the fuzz formation. The effect of W fuzz prevention by the WC formation on the sample surface was more noticeable when the He ion beam had much lower carbon (C) ions content (0.01% C). In this case, the fuzz formation was prevented on the vast majority of the W sample surface, while W fuzz was found in limited and isolated areas. The W surface also shows good resistance to morphology evolution when bombarded by high flux of pure H ions at 900 °C. - Highlights: • Reporting formation of W nanostructure (fuzz) due to low energy He ion beam irradiation. • The effect of adding various percentage of carbon impurity to the He ion beam on the trend of W fuzz formation was studied. • Mitigation of W fuzz formation due to addition of small percentage of carbon to the He ion beam is reported. • The formation of long W nanowires due to He ion beam irradiation mixed with 0.01% carbon ions is reported.

  9. Biologically based analysis of lung cancer incidence in a large Canadian occupational cohort with low-LET low-dose radiation exposure, and comparison with Japanese atomic bomb survivors

    International Nuclear Information System (INIS)

    Hazelton, W.D.; Curtis, S.B.; Moolgavkar, S.H.; Hutchinson, F.; Krewski, D.

    2003-01-01

    Lung cancer incidence is analyzed in a large Canadian National Dose Registry (CNDR) cohort with individual annual dosimetry for low-dose occupational exposure to gamma and tritium radiation using several types of multistage models. The primary analysis utilizes the two-stage clonal expansion model (TSCE), with sensitivity analyses using extensions of this model incorporating additional stages. Characteristic and distinct temporal patterns of risk are found for dose-response affecting early, middle, or late stages of carcinogenesis, e.g. initiation with one or more stages, clonal expansion, or malignant conversion. Fixed lag or lag distributions are used to model time from first malignant cell to incidence. Background rates are analyzed by gender, job classification and birth cohort. Lacking individual smoking data, surrogate doses based on US annual per capita cigarette consumption appear to account for much of the birth cohort effect. Males, with mean cumulative exposure for gamma and tritium of 11.5 mSv and 322 incident lung cancer cases have a significant dose-response with 33 cases attributable to radiation. Female dose-response, with mean cumulative exposure of 1.7 mSv and 78 incident cases, appears similar but is not statistically significant. Findings for males include an inverse-dose-rate effect (increased risk with protraction of a given dose) and dose-response effects on initiation, promotion and malignant conversion, although the effect on initiation is not statistically significant. The excess relative risk (ERR) and excess absolute risk (EAR) depend on age at exposure, duration, dose, and age at follow-up. The ERR increases with dose, tapering off at higher doses, making a plot of ERR against dose concave-downward, similar to apparent low-dose results seen below 1 Sv for solid tumor mortality of atomic bomb survivors. The concave-downward trend of ERR and the inverse-dose-rate effect are both counter to prevailing beliefs about effects of low

  10. RF Surface Impedance Measurement of Polycrystalline and Large Grain Nb Disk Sample at 7.5 GHz

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, Binping [BNL; Geng, Rongli [JLAB; Kelley, Michael J. [W& M, JLAB; Marhauser, Frank [JLAB; Phillips, H. Larry [JLAB; Reece, Charles E. [JLAB; Wang, Haipeng [JLAB

    2009-11-01

    A Surface Impedance Characterization (SIC) system has been proposed at the 2005 SRF workshop and recently updated as detailed at the 2009 PAC conference. Currently the SIC system can measure samples in a temperature range from 2K to 20K exposed to an RF magnetic flux density of less than 3mT. We report on new results of a BCP etched large grain Nb sample measured with this system as compared with previous results of a BCP etched polycrystalline Nb sample. The design of an upgraded SIC system for use at higher magnetic flux densities is on the way to more efficiently investigate correlations between local material characteristics and associated SRF properties, both for preparation studies of bulk niobium and also new thin film SRF developments.

  11. A simple additive-free approach for the synthesis of uniform manganese monoxide nanorods with large specific surface area

    Science.gov (United States)

    Zheng, Mingtao; Zhang, Haoran; Gong, Xuebin; Xu, Ruchun; Xiao, Yong; Dong, Hanwu; Liu, Xiaotang; Liu, Yingliang

    2013-04-01

    A simple additive-free approach is developed to synthesize uniform manganese monoxide (MnO) one-dimensional nanorods, in which only manganese acetate and ethanol were used as reactants. The as-synthesized MnO nanorods were characterized in detail by X-ray diffraction, scanning and transmission electron microscopy (TEM) including high-resolution TEM and selected-area electron diffraction, Fourier transform infrared spectrum, and nitrogen adsorption isotherm measurements. The results indicate that the as-synthesized MnO nanorods present a mesoporous characteristic with large specific surface area (153 m2 g-1), indicating promising applications in catalysis, energy storage, and biomedical image. On the basis of experimental results, the formation mechanism of MnO one-dimensional nanorods in the absence of polymer additives was also discussed.

  12. Large-area gold nanohole arrays fabricated by one-step method for surface plasmon resonance biochemical sensing.

    Science.gov (United States)

    Qi, Huijie; Niu, Lihong; Zhang, Jie; Chen, Jian; Wang, Shujie; Yang, Jingjing; Guo, Siyi; Lawson, Tom; Shi, Bingyang; Song, Chunpeng

    2018-04-01

    Surface plasmon resonance (SPR) nanosensors based on metallic nanohole arrays have been widely reported to detect binding interactions in biological specimens. A simple and effective method for constructing nanoscale arrays is essential for the development of SPR nanosensors. In this work, we report a one-step method to fabricate nanohole arrays by thermal nanoimprinting in the matrix of IPS (Intermediate Polymer Stamp). No additional etching process or supporting substrate is required. The preparation process is simple, time-saving and compatible for roll-to-roll process, potentially allowing mass production. Moreover, the nanohole arrays were integrated into detection platform as SPR sensors to investigate different types of biological binding interactions. The results demonstrate that our one-step method can be used to efficiently fabricate large-area and uniform nanohole arrays for biochemical sensing.

  13. The six year report: Acidification of surface water in Europe and North America. Dose/response relationships and long-term trends

    Energy Technology Data Exchange (ETDEWEB)

    Skjelkvaale, B.L.; Newell, A.D.; Raddum, G.; Johannessen, M.; Hovind, H.; Tjomsland, T.; Wathne, B.M.

    1994-12-31

    This report discusses The International Cooperative Programme on Assessment and Monitoring of Acidification of Rivers and Lakes, which is designed to (1) establish degree and extent of acidification of surface waters, (2) evaluate dose/response relationships and (3) define long-term trends and variations in aquatic chemistry and biota attributable to atmospheric pollution. Data from 200 sites in 14 countries of Europe and North America are available. Dose/response relationships show that the fauna is adapted to different water qualities in different regions, and that critical limits for the fauna must be calculated according to data for the specific region. Long-term trends of water chemistry show decreases in SO{sub 4}{sup 2-} and Ca{sup 2+} at many sites. Nitrate shows no consistent trends. 66 refs., 26 figs., 16 tabs.

  14. Superconductivity across Lifshitz transition and anomalous insulating state in surface K-dosed (Li0.8Fe0.2OH)FeSe.

    Science.gov (United States)

    Ren, Mingqiang; Yan, Yajun; Niu, Xiaohai; Tao, Ran; Hu, Die; Peng, Rui; Xie, Binping; Zhao, Jun; Zhang, Tong; Feng, Dong-Lai

    2017-07-01

    In iron-based superconductors, understanding the relation between superconductivity and electronic structure upon doping is crucial for exploring the pairing mechanism. Recently, it was found that, in iron selenide (FeSe), enhanced superconductivity ( T c of more than 40 K) can be achieved via electron doping, with the Fermi surface only comprising M-centered electron pockets. By using surface K dosing, scanning tunneling microscopy/spectroscopy, and angle-resolved photoemission spectroscopy, we studied the electronic structure and superconductivity of (Li 0.8 Fe 0.2 OH)FeSe in the deep electron-doped regime. We find that a Γ-centered electron band, which originally lies above the Fermi level ( E F ), can be continuously tuned to cross E F and contribute a new electron pocket at Γ. When this Lifshitz transition occurs, the superconductivity in the M-centered electron pocket is slightly suppressed, and a possible superconducting gap with a small size (up to ~5 meV) and a dome-like doping dependence is observed on the new Γ electron pocket. Upon further K dosing, the system eventually evolves into an insulating state. Our findings provide new clues to understand superconductivity versus Fermi surface topology and the correlation effect in FeSe-based superconductors.

  15. Evaluation of the enter surface dose, dose in organ and E effective dose, received by personnel and patients in studies of endoscopic retrograde cholangeopancreatography in the General Hospital of Mexico

    International Nuclear Information System (INIS)

    Reyes, S.; Gama T, G.; Beristain, M.; Espino, H.

    2006-01-01

    The ESD for patient and personal is measured: gastroenterologuist endoscopist G1, A1 Assistant and A2 instrumentist that carried out 22 independent therapeutic procedures of CPRE, in a fluoroscopy equipment Toshiba trademark with tube under the table, operated in automatic exposure mode, CAE to average tensions of 80 kVp. The measurement is carried out with film dosemeters of double emulsion Kodak Type 2 trademark, calibrated in terms of H * for the energy of the 137 Cs, first it is determined the films sensitivity like function of the optical density DO, and second the ESD for the effective energy of the radiation beam (50 keV), in three different points from the dosemeter (C, D and H). The films was placed for the personnel in: right hand, front (eye), thyroid and thorax (under D and out F of the lead apron); in the case of the patient three positions were used: thorax, hepatic region and pelvis. The mean values of the ESD and it standard deviation SD in mGy units are determined by: study, personnel, film position in doctor and patient, dosemeter measurement point. The calculated doses in organ are also determined for the patient in the thorax region, liverwort and pelvis its are agreement with the NRPB SR 262 report. Finally the H E and E for medical personnel and patients are estimated demonstrating that its are not exceeded the annual dose limits for the case of the OEP. In the case of the the OEP have for the D thorax an ESD max = 0.04 mGy that one corresponds an H E = 0.02 and E = 0.01 mSv. (Author)

  16. Dynamical Orientation of Large Molecules on Oxide Surfaces and its Implications for Dye-Sensitized Solar Cells

    KAUST Repository

    Brennan, Thomas P.

    2013-11-12

    A dual experimental-computational approach utilizing near-edge X-ray absorption fine structure (NEXAFS) spectroscopy and density functional theory-molecular dynamics (DFT-MD) is presented for determining the orientation of a large adsorbate on an oxide substrate. A system of interest in the field of dye-sensitized solar cells is studied: an organic cyanoacrylic acid-based donor-π-acceptor dye (WN1) bound to anatase TiO2. Assessment of nitrogen K-edge NEXAFS spectra is supported by calculations of the electronic structure that indicate energetically discrete transitions associated with the two π systems of the C-N triple bond in the cyanoacrylic acid portion of the dye. Angle-resolved NEXAFS spectra are fitted to determine the orientation of these two orbital systems, and the results indicate an upright orientation of the adsorbed dye, 63 from the TiO2 surface plane. These experimental results are then compared to computational studies of the WN1 dye on an anatase (101) TiO2 slab. The ground state structure obtained from standard DFT optimization is less upright (45 from the surface) than the NEXAFS results. However, DFT-MD simulations, which provide a more realistic depiction of the dye at room temperature, exhibit excellent agreement - within 2 on average - with the angles determined via NEXAFS, demonstrating the importance of accounting for the dynamic nature of adsorbate-substrate interactions and DFT-MD\\'s powerful predictive abilities. © 2013 American Chemical Society.

  17. A Stream Tilling Approach to Surface Area Estimation for Large Scale Spatial Data in a Shared Memory System

    Science.gov (United States)

    Liu, Jiping; Kang, Xiaochen; Dong, Chun; Xu, Shenghua

    2017-12-01

    Surface area estimation is a widely used tool for resource evaluation in the physical world. When processing large scale spatial data, the input/output (I/O) can easily become the bottleneck in parallelizing the algorithm due to the limited physical memory resources and the very slow disk transfer rate. In this paper, we proposed a stream tilling approach to surface area estimation that first decomposed a spatial data set into tiles with topological expansions. With these tiles, the one-to-one mapping relationship between the input and the computing process was broken. Then, we realized a streaming framework towards the scheduling of the I/O processes and computing units. Herein, each computing unit encapsulated a same copy of the estimation algorithm, and multiple asynchronous computing units could work individually in parallel. Finally, the performed experiment demonstrated that our stream tilling estimation can efficiently alleviate the heavy pressures from the I/O-bound work, and the measured speedup after being optimized have greatly outperformed the directly parallel versions in shared memory systems with multi-core processors.

  18. A Stream Tilling Approach to Surface Area Estimation for Large Scale Spatial Data in a Shared Memory System

    Directory of Open Access Journals (Sweden)

    Liu Jiping

    2017-12-01

    Full Text Available Surface area estimation is a widely used tool for resource evaluation in the physical world. When processing large scale spatial data, the input/output (I/O can easily become the bottleneck in parallelizing the algorithm due to the limited physical memory resources and the very slow disk transfer rate. In this paper, we proposed a stream tilling approach to surface area estimation that first decomposed a spatial data set into tiles with topological expansions. With these tiles, the one-to-one mapping relationship between the input and the computing process was broken. Then, we realized a streaming framework towards the scheduling of the I/O processes and computing units. Herein, each computing unit encapsulated a same copy of the estimation algorithm, and multiple asynchronous computing units could work individually in parallel. Finally, the performed experiment demonstrated that our stream tilling estimation can efficiently alleviate the heavy pressures from the I/O-bound work, and the measured speedup after being optimized have greatly outperformed the directly parallel versions in shared memory systems with multi-core processors.

  19. A Mobile System for Measuring Water Surface Velocities Using Unmanned Aerial Vehicle and Large-Scale Particle Image Velocimetry

    Science.gov (United States)

    Chen, Y. L.

    2015-12-01

    Measurement technologies for velocity of river flow are divided into intrusive and nonintrusive methods. Intrusive method requires infield operations. The measuring process of intrusive methods are time consuming, and likely to cause damages of operator and instrument. Nonintrusive methods require fewer operators and can reduce instrument damages from directly attaching to the flow. Nonintrusive measurements may use radar or image velocimetry to measure the velocities at the surface of water flow. The image velocimetry, such as large scale particle image velocimetry (LSPIV) accesses not only the point velocity but the flow velocities in an area simultaneously. Flow properties of an area hold the promise of providing spatially information of flow fields. This study attempts to construct a mobile system UAV-LSPIV by using an unmanned aerial vehicle (UAV) with LSPIV to measure flows in fields. The mobile system consists of a six-rotor UAV helicopter, a Sony nex5T camera, a gimbal, an image transfer device, a ground station and a remote control device. The activate gimbal helps maintain the camera lens orthogonal to the water surface and reduce the extent of images being distorted. The image transfer device can monitor the captured image instantly. The operator controls the UAV by remote control device through ground station and can achieve the flying data such as flying height and GPS coordinate of UAV. The mobile system was then applied to field experiments. The deviation of velocities measured by UAV-LSPIV of field experiments and handhold Acoustic Doppler Velocimeter (ADV) is under 8%. The results of the field experiments suggests that the application of UAV-LSPIV can be effectively applied to surface flow studies.

  20. Adsorption and correlations of selected aromatic compounds on a KOH-activated carbon with large surface area.

    Science.gov (United States)

    Yang, Kun; Zhu, Lianghong; Yang, Jingjing; Lin, Daohui

    2018-03-15

    Knowledge of adsorption mechanism and behavior of organic compounds by KOH-activated carbons (KOH-ACs) from wastewater is crucial to its environmental application in wastewater treatment as adsorbent. A superior adsorbent, KOH-activated carbon (KOH-AC), with large surface area (3143m 2 /g), total pore volume of 2.03cm 3 /g, relatively low micropore fraction of 53.2%, and having adsorption capacities of organic compounds up to >1000mg/g, was prepared. It is an adsorbent significantly different with common ACs because the molecular sieving effect, widely observed for common ACs, is insignificant for KOH-AC. This difference could be attributed to the lower micropore fraction of KOH-AC than common ACs. A negative relationship of adsorption capacity of 25 aromatic compounds (including phenols, anilines, nitrobenzenes and polycyclic aromatic hydrocarbons) with chemical melting point was observed, suggesting that adsorption is dependent on the packing efficiency and stacking density of molecules on KOH-AC. A linear solvation energy relationships of adsorption affinity of 25 aromatic compounds with solute solvatochromic parameters was also observed, that can be used to quantify the contributions of π-π interaction, hydrogen-bonding interaction and hydrophobic effect to adsorption on KOH-AC. Combined with the reported results of adsorption of organic compounds on carbon nanotubes and biochars, it was also observed that external surface area of adsorbents is controlling the packing efficiency and stacking density of molecules on adsorbents and thus affecting adsorption capacity of organic compounds. Moreover, micropore surface area and the fraction of micropores are the adsorbent properties mainly affecting adsorption affinity of organic compounds. The observations and the developed correlations in this study would be helpful in the application of KOH-AC as superior adsorbent by enhancing the understanding of adsorption mechanisms of organic compounds on KOH-AC and by

  1. Design and analysis of drum lathe for manufacturing large-scale optical microstructured surface and load characteristics of aerostatic spindle

    Science.gov (United States)

    Wu, Dongxu; Qiao, Zheng; Wang, Bo; Wang, Huiming; Li, Guo

    2014-08-01

    In this paper, a four-axis ultra-precision lathe for machining large-scale drum mould with microstructured surface is presented. Firstly, because of the large dimension and weight of drum workpiece, as well as high requirement of machining accuracy, the design guidelines and component parts of this drum lathe is introduced in detail, including control system, moving and driving components, position feedback system and so on. Additionally, the weight of drum workpiece would result in the structural deformation of this lathe, therefore, this paper analyses the effect of structural deformation on machining accuracy by means of ANSYS. The position change is approximately 16.9nm in the X-direction(sensitive direction) which could be negligible. Finally, in order to study the impact of bearing parameters on the load characteristics of aerostatic journal bearing, one of the famous computational fluid dynamics(CFD) software, FLUENT, is adopted, and a series of simulations are carried out. The result shows that the aerostatic spindle has superior performance of carrying capacity and stiffness, it is possible for this lathe to bear the weight of drum workpiece up to 1000kg since there are two aerostatic spindles in the headstock and tailstock.

  2. Assessing actual evapotranspiration via surface energy balance aiming to optimize water and energy consumption in large scale pressurized irrigation systems

    Science.gov (United States)

    Awada, H.; Ciraolo, G.; Maltese, A.; Moreno Hidalgo, M. A.; Provenzano, G.; Còrcoles, J. I.

    2017-10-01

    Satellite imagery provides a dependable basis for computational models that aimed to determine actual evapotranspiration (ET) by surface energy balance. Satellite-based models enables quantifying ET over large areas for a wide range of applications, such as monitoring water distribution, managing irrigation and assessing irrigation systems' performance. With the aim to evaluate the energy and water consumption of a large scale on-turn pressurized irrigation system in the district of Aguas Nuevas, Albacete, Spain, the satellite-based image-processing model SEBAL was used for calculating actual ET. The model has been applied to quantify instantaneous, daily, and seasonal actual ET over high- resolution Landsat images for the peak water demand season (May to September) and for the years 2006 - 2008. The model provided a direct estimation of the distribution of main energy fluxes, at the instant when the satellite overpassed over each field of the district. The image acquisition day Evapotranspiration (ET24) was obtained from instantaneous values by assuming a constant evaporative fraction (Λ) for the entire day of acquisition; then, monthly and seasonal ET were estimated from the daily evapotranspiration (ETdaily) assuming that ET24 varies in proportion to reference ET (ETr) at the meteorological station, thus accounting for day to day variation in meteorological forcing. The comparison between the hydrants water consumption and the actual evapotranspiration, considering an irrigation efficiency of 85%, showed that a considerable amount of water and energy can be saved at district level.

  3. Hypercrosslinked large surface area porous polymer monoliths for hydrophilic interaction liquid chromatography of small molecules featuring zwitterionic functionalities attached to gold nanoparticles held in layered structure

    OpenAIRE

    Lv, Yongqin; Lin, Zhixing; Svec, Frantisek

    2012-01-01

    A novel approach to porous polymer monoliths hypercrosslinked to obtain large surface areas and modified with zwitterionic functionalities through the attachment of gold nanoparticles in a layered architecture has been developed. The capillary columns were used for the separation of small molecules in hydrophilic interaction liquid chromatography mode. First, a monolith with a very large surface area of 430 m2/g was prepared by hypercrosslinking from a generic poly(4-methylstyrene-co-vinylben...

  4. SU-F-J-52: A Novel Approach to X-Ray Tube Quality Assurance for CBCT Systems in Order to Better Assess the Patient Imaging Dose in a Large, Multi-Unit Treatment Facility

    Energy Technology Data Exchange (ETDEWEB)

    Buckley, L; Lambert, C; Nyiri, B; Gerig, L [The Ottawa Hospital Cancer Ctr., Ottawa, ON (Canada); Webb, R [Elekta, Montreal, Quebec (Canada)

    2016-06-15

    Purpose: To standardize the tube calibration for Elekta XVI cone beam CT (CBCT) systems in order to provide a meaningful estimate of the daily imaging dose and reduce the variation between units in a large centre with multiple treatment units. Methods: Initial measurements of the output from the CBCT systems were made using a Farmer chamber and standard CTDI phantom. The correlation between the measured CTDI and the tube current was confirmed using an Unfors Xi detector which was then used to perform a tube current calibration on each unit. Results: Initial measurements showed measured tube current variations of up to 25% between units for scans with the same image settings. In order to reasonably estimate the imaging dose, a systematic approach to x-ray generator calibration was adopted to ensure that the imaging dose was consistent across all units at the centre and was adopted as part of the routine quality assurance program. Subsequent measurements show that the variation in measured dose across nine units is on the order of 5%. Conclusion: Increasingly, patients receiving radiation therapy have extended life expectancies and therefore the cumulative dose from daily imaging should not be ignored. In theory, an estimate of imaging dose can be made from the imaging parameters. However, measurements have shown that there are large differences in the x-ray generator calibration as installed at the clinic. Current protocols recommend routine checks of dose to ensure constancy. The present study suggests that in addition to constancy checks on a single machine, a tube current calibration should be performed on every unit to ensure agreement across multiple machines. This is crucial at a large centre with multiple units in order to provide physicians with a meaningful estimate of the daily imaging dose.

  5. OMI/Aura Surface UVB Irradiance and Erythemal Dose Daily L2 Global Gridded 0.25 degree x 0.25 degree V3 (OMUVBG) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — This is Level-2G daily global gridded Aura-OMI Spectral Surface UVB Irradiance and Erythemal Dose product (OMUVBG). The OMUVBG is a special Level-2 Global Gridded...

  6. OMI/Aura Surface UVB Irradiance and Erythemal Dose Daily L3 Global Gridded 1.0 degree x 1.0 degree V3 (OMUVBd) at GES DISC

    Data.gov (United States)

    National Aeronautics and Space Administration — This is Level-3 daily global gridded Aura-OMI Spectral Surface UVB Irradiance and Erythemal Dose product (OMUVBd). The OMUVBd product contains global erythemally...

  7. Study of electronic field emission from large surfaces under static operating conditions and hyper-frequency; Etude de l'emision electronique par effet de champ sur des surfaces larges en regime statique et hyperfrequence

    Energy Technology Data Exchange (ETDEWEB)

    Luong, M

    1997-09-01

    The enhanced electronic field emission from large area metallic surfaces lowers performances of industrial devices that have to sustain high electric field under vacuum. Despite of numerous investigations in the past, the mechanisms of such an emission have never been well clarified. Recently, research in our laboratory has pointed out the importance played by conducting sites (particles and protrusions). A refined geometrical model, called superposed protrusions model has been proposed to explain the enhanced emission by local field enhancement. As a logical continuation, the present work aims at testing this model and, in the same time, investigating the means to suppress the emission where it is undesirable. Thus, we have showed: the cause of current fluctuations in a continuous field regime (DC), the identity of emission characteristics ({beta}, A{sub e}) in both radiofrequency (RF) and DC regimes, the effectiveness of a thermal treatment by extern high density electronic bombardment, the effectiveness of a mechanical treatment by high pressure rinsing with ultra pure water, the mechanisms and limits of an in situ RF processing. Furthermore, the electronic emission from insulating particles has also been studied concurrently with a spectral analysis of the associated luminous emission. Finally, the refined geometrical model for conducting sites is reinforced while another model is proposed for some insulating sites. Several emission suppressing treatments has been explored and validated. At last, the characteristic of a RF pulsed field emitted electron beam has been checked for the first time as a possible application of such a field emission. (author)

  8. High-dose therapy in diffuse large cell lymphoma: results and prognostic factors in 452 patients from the GEL-TAMO Spanish Cooperative Group.

    Science.gov (United States)

    Caballero, M D; Pérez-Simón, J A; Iriondo, A; Lahuerta, J J; Sierra, J; Marín, J; Gandarillas, M; Arranz, R; Zuazu, J; Rubio, V; Fernández de Sevilla, A; Carreras, E; García-Conde, J; García-Laraña, J; Grande, C; Sureda, A; Vidal, M J; Rifón, J; Pérez-Equiza, C; Varela, R; Moraleda, J M; García Ruíz, J C; Albó, C; Cabrera, R; San Miguel, J F; Conde, E

    2003-01-01

    The purpose of this study was to analyse the results and prognostic factors influencing overall survival (OS) and disease-free survival (DFS) in 452 patients diagnosed with diffuse large cell lymphomas (DLCL) treated with high-dose therapy (HDT) included in the Grupo Español de Linfomas/Trasplante Autólogo de Médula Osea (GEL-TAMO) Spanish registry. At transplantation, median age was 42 years (range 15-73), 146 patients (32%) were transplanted in first complete remission (1st CR), 19% in second CR (2nd CR) and 47% had active disease: sensitive disease in 157 (35%) patients [95 were in first partial remission (1st PR) and 62 in second PR (2nd PR)] and refractory disease in 55 (12%) patients. Age-adjusted International Prognostic Index (IPI) was 2 or 3 in 51 patients (12%). Conditioning regimen consisted of BEAM (carmustine, etoposide, cytarabine and melphalan) in 39% of patients, BEAC (carmustine, etoposide, cytarabine and cyclophosphamide) in 33%, CBV (carmustine, etoposide and cyclophosphamide) in 10% and cyclophosphamide plus total body irradiation (TBI) in 12%. Estimated overall survival (OS) and disease-free survival (DFS) at 5 years were 53% and 43%, respectively. The transplant-related mortality was 11% (53 cases). By multivariate analysis three variables significantly influenced OS and DFS: number of protocols to reach 1st CR, disease status at transplant and TBI in the conditioning regimen. Age-adjusted IPI at transplantation also influenced OS. Prolonged OS and DFS can be achieved in patients with DLCL after HDT and our results suggest that the best line of chemotherapy should be used up-front in patients considered as candidates for HDT in order to obtain an early CR. Resistant patients are not good candidates for HDT and they should be offered newer strategies. Finally, polichemotherapy conditioning regimens offer better results compared with TBI.

  9. A probabilistic approach to quantify the uncertainties in internal dose assessment using response surface and neural network

    International Nuclear Information System (INIS)

    Baek, M.; Lee, S.K.; Lee, U.C.; Kang, C.S.

    1996-01-01

    A probabilistic approach is formulated to assess the internal radiation exposure following the intake of radioisotopes. This probabilistic approach consists of 4 steps as follows: (1) screening, (2) quantification of uncertainties, (3) propagation of uncertainties, and (4) analysis of output. The approach has been applied for Pu-induced internal dose assessment and a multi-compartment dosimetric model is used for internal transport. In this approach, surrogate models of original system are constructed using response and neural network. And the results of these surrogate models are compared with those of original model. Each surrogate model well approximates the original model. The uncertainty and sensitivity analysis of the model parameters are evaluated in this process. Dominant contributors to each organ are identified and the results show that this approach could serve a good tool of assessing the internal radiation exposure

  10. Individualized recombinant human follicle-stimulating hormone dosing using the CONSORT calculator in assisted reproductive technology: a large, multicenter, observational study of routine clinical practice.

    Science.gov (United States)

    Naether, Olaf Gj; Tandler-Schneider, Andreas; Bilger, Wilma

    2015-01-01

    This postmarketing surveillance survey was conducted to investigate the utility of the CONsistency in r-FSH Starting dOses for individualized tReatmenT (CONSORT) calculator for individualizing recombinant human follicle-stimulating hormone (r-hFSH) starting doses for controlled ovarian stimulation (COS) in routine clinical practice. This was a 3-year, open-label, observational study evaluating data from women undergoing COS for assisted reproductive technology at 31 German fertility centers. Physicians stated their recommended r-hFSH starting dose, then generated a CONSORT-recommended r-hFSH starting dose. Physicians could prescribe any r-hFSH starting dose. The primary objective was to compare the r-hFSH starting dose recommended by the physician with the CONSORT-calculated dose and that prescribed. Statistical analyses were conducted post hoc. Data were collected from 2,579 patients; the mean (standard deviation [SD]) age was 30.5 (2.93) years (range: 19-40 years). The mean (SD) CONSORT-calculated r-hFSH starting dose was significantly lower than the physician-recommended dose (134.5 [38.0] IU versus 164.6 [47.1] IU; PCONSORT-calculated doses were prescribed for 27.3% (number [n] =677) of patients, and non-CONSORT-calculated doses prescribed for 72.7% (n=1,800). The mean (SD) number of oocytes retrieved per patient was 10.6 (6.15) and 11.4 (6.66) in the CONSORT and non-CONSORT groups, respectively; the mean (SD) number of embryos transferred per patient was 1.98 (0.41) and 2.03 (0.45), respectively. Clinical pregnancy rates per COS cycle were 38.8% (CONSORT) and 34.8% (non-CONSORT) (P=0.142); clinical pregnancy rates per embryos transferred were 45.0% and 39.5%, respectively (P=0.049). Miscarriage occurred in 14.8% of all clinical pregnancies ( 12.5%; non- 15.3%). The rate of grade 3 ovarian hyperstimulation syndrome (OHSS) was 0.3% (n=2) in the CONSORT group and 0.6% (n=11) in the non-CONSORT group. OHSS led to hospitalization in 0.81% (n=21) of cases (CONSORT

  11. Complete response of endemic Kaposi sarcoma lesions with high-dose-rate brachytherapy: treatment method, results, and toxicity using skin surface applicators.

    Science.gov (United States)

    Kasper, Michael E; Richter, Sam; Warren, Nicholas; Benda, Rashmi; Shang, Charles; Ouhib, Zoubir

    2013-01-01

    To analyze the clinical outcome of Kaposi sarcoma skin lesions treated with high-dose-rate (HDR) brachytherapy in patients with a minimum of 2 years of followup. Between February 2006 and July 2008, all patients with Kaposi sarcoma who received (192)Ir HDR brachytherapy using a skin surface applicator were evaluated for clinical response. Responses to treatment and toxicity were scored using standard criteria. Sixteen cases were collected. Treatment was delivered in four to six fractions, over a period of approximately 12 days. The specified dose ranged from 24 to 35Gy. Median followup the lesion was 41.4 months. No lesion was greater than 2cm. All patients had a complete response to treatment, with no evidence of local recurrence or tumor progression. Thirteen lesions developed Grade 1 and two lesions had Grade 2 acute skin reactions. One patient developed late skin changes with telangiectasias and hypopigmentation. HDR brachytherapy treatment seems to be an effective noninvasive option for patients with small cutaneous Kaposi sarcoma lesions, delivering excellent cosmesis and local control in our small series. Fewer fractions over a shorter period used in our group offer patients more convenience compared with other common regimens. Although HDR is being used more frequently for many surface applications, additional clinical studies with larger numbers of patients and longer followup are needed to confirm the general impression that it is an excellent option for many patients. Copyright © 2013 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  12. Secondary shock features for large surface explosions: results from the Sayarim Military Range, Israel and other experiments

    Science.gov (United States)

    Gitterman, Y.

    2014-05-01

    A series of surface explosions was designed and conducted by the Geophysical Institute of Israel at the Sayarim Military Range in the Negev desert, including two large-scale explosions: approx. 82 tons of high explosives in 2009, and approx. 100 tons of low-grade ANFO explosives in 2011. The main goal of the explosions was to provide large controlled sources for calibration of global infrasound stations designated for monitoring nuclear tests; however, the geophysical experiment also provided valuable observations for shock wave research. High-pressure gauges were deployed at distances between 100 and 600 m to record air blast properties and to provide reliable estimation of the true charge yield compared to the design value. Secondary shock phenomena were clearly observed at all near-source gauges as characteristic shock wave shapes. Secondary shocks were also observed at numerous seismic and acoustic sensors deployed in the range 0.3-20 km as acoustic phases. Empirical relationships for standard air blast parameters (peak pressure and impulse) and for a new parameter called secondary shock time delay, as a function of distance, were established and analyzed. The standard parameters, scaled by the cubic root of the estimated TNT yield, were found to be consistent for all analyzed explosions. However, the scaled secondary shock delays were clearly separated for the 2009 and 2011 explosions, thus demonstrating dependence on the explosive type. Additionally, air blast records from other experiments were used to extend the charge and distance ranges for the secondary shock observation, and showed consistency with the Sayarim data. Analysis and interpretation of observed features of the secondary shock phenomenon are proposed and a new empirical relationship of scaled secondary shock delay versus scaled distance is established. The results suggest that the secondary shock delay can be used as a new additional waveform feature for simple and cost-effective explosive

  13. Radioactivity levels of 238U and 232Th, the α and β activities and associated dose rates from surface soil in Ulu Tiram, Malaysia

    International Nuclear Information System (INIS)

    Abdul Rahman, A.T.; Ramli, A.T.

    2007-01-01

    A survey was carried out to determine terrestrial gamma radiation dose rates, the concentration level of 238 U and 232 Th and α and β activities for the surface soil in Ulu Tiram, Malaysia. A 125 measurements were performed using a NaI(Tl) gamma-ray detector with crystal size of 1' x 1' on 15 soil samples collected from the site area about 102 km 2 . 238 U and 232 Th concentrations were determined in soils by using hyper pure germanium (HPGe) gamma-ray spectrometry. The activity of α and β from the surface soil was counted by using alpha beta counting system. The average value of 238 U and 232 Th concentrations in soil samples collected are 3.63±0.39 ppm within the range of 1.74±0.20 to 4.58±0.48 and 43.00±2.31 ppm within the range of 10.68±0.76 to 82.10±4.01 ppm, respectively. The average estimate of α and β activity in soil samples collected are 0.65±0.09 Bq x g -1 and 0.68±0.08 Bq x g -1 , respectively. The average of terrestrial gamma-radiation dose rates measured in Ulu Tiram was found to be 200 nGy x h -1 , within the range of 96 to 409 nGy x h -1 . The population weighted outdoor annual effective dose was 1.2 mSv. (author)

  14. Polyunsaturated Aldehydes from Large Phytoplankton of the Atlantic Ocean Surface (42°N to 33°S

    Directory of Open Access Journals (Sweden)

    Ana Bartual

    2014-01-01

    Full Text Available Polyunsaturated aldehydes (PUAs are organic compounds mainly produced by diatoms, after cell wounding. These compounds are increasingly reported as teratogenic for species of grazers and deleterious for phytoplanktonic species, but there is still scarce information regarding concentration ranges and the composition of PUAs in the open ocean. In this study, we analyzed the spatial distribution and the type of aldehydes produced by the large-sized (>10 μm phytoplankton in the Atlantic Ocean surface. Analyses were conducted on PUAs released after mechanical disruption of the phytoplankton cells, referred to here as potential PUAs (pPUAs. Results show the ubiquitous presence of pPUA in the open ocean, including upwelling areas, as well as oligotrophic gyres. Total pPUA concentrations ranged from zero to 4.18 pmol from cells in 1 L. Identified PUAs were heptadienal, octadienal and decadienal, with heptadienal being the most common (79% of total stations. PUA amount and composition across the Atlantic Ocean was mainly related to the nitrogen:phosphorus ratio, suggesting nutrient-driven mechanisms of PUA production. Extending the range of trophic conditions considered by adding data reported for productive coastal waters, we found a pattern of PUA variation in relation to trophic status.

  15. Integrated surface water-groundwater modeling for interpreting ecohydrological processes in large arid and semi-arid river basins

    Science.gov (United States)

    Tian, Yong; Zheng, Yi; Zheng, Chunmiao; Wu, Bin; Wu, Xin

    2015-04-01

    Ecohydrological processes in arid and semi-arid environments are sensitive to both climate conditions and human activities, but the response mechanisms have been rarely explored for large river basins via an integrated modeling approach. In this study, GSFLOW, a USGS model coupling PRMS and MODFLOW, was improved to explicitly simulate flow diversion, groundwater pumping and agricultural irrigation. The improved GSFLOW was then applied in the Heihe River Basin (HRB), the second largest inland river basin in China, to characterize ecohydrological processes at different spatial and temporal scales. The integrated model is grid-based for both its surface and subsurface domains. It assimilated multiple types of data including classic hydrological observations and remote sensing-based evapotranspiration (ET) and leaf area index (LAI) products, and eventually produced a coherent understanding on the regional water cycle at different spatial and temporal scales. Complicated multi-scale features of both ET and vegetation growth processes in the study area were unraveled, and insights on tackling the existing water conflicts were achieved.

  16. Characterizing the lower log region of the atmospheric surface layer via large-scale particle tracking velocimetry

    Science.gov (United States)

    Rosi, Giuseppe A.; Sherry, Michael; Kinzel, Matthias; Rival, David E.

    2014-05-01

    As a first step toward characterizing coherent structures within the atmospheric surface layer (ASL), measurements obtained via a large-scale particle tracking velocimetry (LS-PTV) system were validated against wind-measurement station data as well as canonical turbulent boundary layer studies. The LS-PTV system resolves three-dimensional, Lagrangian tracks over a 16 m3 volume. Mean-velocity measurements, as well as vertical and shear Reynolds-stress measurements, generally agreed with wind-measurement station data and Reynolds-stress profiles referenced from literature. The probability distributions for streamwise, spanwise and vertical velocity-fluctuation components appear normally distributed about zero. Furthermore, the probability distributions for all three components of Lagrangian acceleration were exponential and followed the parametrization curve from LaPorta et al. (Lett Nat 409:1017-1019, 2001). Lastly, the vorticity probability distributions were exponential and symmetric about zero, which matches findings from Balint et al. (Fluid Mech 228:53-86, 1991). The vorticity intensity measured by the LS-PTV system was less than values from Priyadarshana et al. (Fluid Mech 570:307-346, 2007), which is attributed to the low spatial resolution. However, the average spacing of 0.5 m between tracer particles is deemed sufficient for the future characterization of vortical structures within the ASL.

  17. Variability of cold season surface air temperature over northeastern China and its linkage with large-scale atmospheric circulations

    Science.gov (United States)

    Zhuang, Yuanhuang; Zhang, Jingyong; Wang, Lin

    2018-05-01

    Cold temperature anomalies and extremes have profound effects on the society, the economy, and the environment of northeastern China (NEC). In this study, we define the cold season as the months from October to April, and investigate the variability of cold season surface air temperature (CSAT) over NEC and its relationships with large-scale atmospheric circulation patterns for the period 1981-2014. The empirical orthogonal function (EOF) analysis shows that the first EOF mode of the CSAT over NEC is characterized by a homogeneous structure that describes 92.2% of the total variance. The regionally averaged CSAT over NEC is closely linked with the Arctic Oscillation ( r = 0.62, 99% confidence level) and also has a statistically significant relation with the Polar/Eurasian pattern in the cold season. The positive phases of the Arctic Oscillation and the Polar/Eurasian pattern tend to result in a positive geopotential height anomaly over NEC and a weakened East Asian winter monsoon, which subsequently increase the CSAT over NEC by enhancing the downward solar radiation, strengthening the subsidence warming and warm air advection. Conversely, the negative phases of these two climate indices result in opposite regional atmospheric circulation anomalies and decrease the CSAT over NEC.

  18. Study on brain hemodynamics function according to data of rheoencephalography during multimodality treatment of oncologic patients with the use of general controlled artificial hyperthermia with hyperglycemia or with large insulin doses

    International Nuclear Information System (INIS)

    Lysenko, E.V.

    1990-01-01

    For the first time the effect of single and multiple treatments of artificial hyperthermia (AHT) with hyperglycemia (HG) or with large insulin doses on cerebral circulation of oncologic patients is studied. Cerebral hemodynamics was studied by rheoencephalography. The conclusion is made about the unidirectional AHT effect regardless of the bacrground used. 5 refs.; 4 tabs

  19. Experimental dosing of wetlands with coagulants removes mercury from surface water and decreases mercury bioaccumulation in fish

    Science.gov (United States)

    Ackerman, Joshua T.; Kraus, Tamara E.C.; Fleck, Jacob A.; Krabbenhoft, David P.; Horwarth, William R.; Bachand, Sandra M.; Herzog, Mark; Hartman, Christopher; Bachand, Philip A.M.

    2015-01-01

    Mercury pollution is widespread globally, and strategies for managing mercury contamination in aquatic environments are necessary. We tested whether coagulation with metal-based salts could remove mercury from wetland surface waters and decrease mercury bioaccumulation in fish. In a complete randomized block design, we constructed nine experimental wetlands in California’s Sacramento–San Joaquin Delta, stocked them with mosquitofish (Gambusia affinis), and then continuously applied agricultural drainage water that was either untreated (control), or treated with polyaluminum chloride or ferric sulfate coagulants. Total mercury and methylmercury concentrations in surface waters were decreased by 62% and 63% in polyaluminum chloride treated wetlands and 50% and 76% in ferric sulfate treated wetlands compared to control wetlands. Specifically, following coagulation, mercury was transferred from the filtered fraction of water into the particulate fraction of water which then settled within the wetland. Mosquitofish mercury concentrations were decreased by 35% in ferric sulfate treated wetlands compared to control wetlands. There was no reduction in mosquitofish mercury concentrations within the polyaluminum chloride treated wetlands, which may have been caused by production of bioavailable methylmercury within those wetlands. Coagulation may be an effective management strategy for reducing mercury contamination within wetlands, but further studies should explore potential effects on wetland ecosystems.

  20. Highly efficient and large-scale fabrication of superhydrophobic alumina surface with strong stability based on self-congregated alumina nanowires.

    Science.gov (United States)

    Peng, Shan; Tian, Dong; Yang, Xiaojun; Deng, Wenli

    2014-04-09

    In this study, a large-area superhydrophobic alumina surface with a series of superior properties was fabricated via an economical, simple, and highly effective one-step anodization process, and subsequently modified with low-surface-energy film. The effects of the anodization parameters including electrochemical anodization time, current density, and electrolyte temperature on surface morphology and surface wettability were investigated in detail. The hierarchical alumina pyramids-on-pores (HAPOP) rough structure which was produced quickly through the one-step anodization process together with a low-surface-energy film deposition [1H,1H,2H,2H-perfluorodecyltriethoxysilane (PDES) and stearic acid (STA)] confer excellent superhydrophobicity and an extremely low sliding angle. Both the PDES-modified superhydrophobic (PDES-MS) and the STA-modified superhydrophobic (STA-MS) surfaces present fascinating nonwetting and extremely slippery behaviors. The chemical stability and mechanical durability of the PDES-MS and STA-MS surfaces were evaluated and discussed. Compared with the STA-MS surface, the as-prepared PDES-MS surface possesses an amazing chemical stability which not only can repel cool liquids (water, HCl/NaOH solutions, around 25 °C), but also can show excellent resistance to a series of hot liquids (water, HCl/NaOH solutions, 30-100 °C) and hot beverages (coffee, milk, tea, 80 °C). Moreover, the PDES-MS surface also presents excellent stability toward immersion in various organic solvents, high temperature, and long time period. In particular, the PDES-MS surface achieves good mechanical durability which can withstand ultrasonication treatment, finger-touch, multiple fold, peeling by adhesive tape, and even abrasion test treatments without losing superhydrophobicity. The corrosion resistance and durability of the diverse-modified superhydrophobic surfaces were also examined. These fascinating performances makes the present method suitable for large

  1. Estimating Evapotranspiration over Heterogeneously Vegetated Surfaces using Large Aperture Scintillometer, LiDAR, and Airborne Multispectral Imagery

    Science.gov (United States)

    Geli, H. M.; Neale, C. M.; Pack, R. T.; Watts, D. R.; Osterberg, J.

    2011-12-01

    Estimates of evapotranspiration (ET) over heterogeneous areas is challenging especially in water-limited sparsely vegetated environments. New techniques such as airborne full-waveform LiDAR (Light Detection and Ranging) and high resolution multispectral and thermal imagery can provide enough detail of sparse canopies to improve energy balance model estimations as well as footprint analysis of scintillometer data. The objectives of this study were to estimate ET over such areas and develop methodologies for the use of these airborne data technologies. Because of the associated heterogeneity, this study was conducted over the Cibola National wildlife refuge, southern California on an area dominated with tamarisk (salt cedar) forest (90%) interspersed with arrowweed and bare soil (10%). A set of two large aperture scintillometers (LASs) were deployed over the area to provide estimates of sensible heat flux (HLAS). The LASs were distributed over the area in a way that allowed capturing different surface spatial heterogeneity. Bowen ratio systems were used to provide hydrometeorological variables and surface energy balance fluxes (SEBF) (i.e. Rn, G, H, and LE) measurements. Scintillometer-based estimates of HLAS were improved by considering the effect of the corresponding 3D footprint and the associated displacement height (d) and the roughness length (z0) following Geli et al. (2011). The LiDAR data were acquired using the LASSI Lidar developed at Utah State University (USU). The data was used to obtain 1-m spatial resolution DEM's and vegetation canopy height to improve the HLAS estimates. The BR measurements of Rn and G were combined with LAS estimates, HLAS, to provide estimates of LELASas a residual of the energy balance equation. A thermal remote sensing model namely the two source energy balance (TSEB) of Norman et al. (1995) was applied to provide spatial estimates of SEBF. Four airborne images at 1-4 meter spatial resolution acquired using the USU airborne

  2. Dose escalation in large anterior skull-base tumors by means of IMRT. First experience with the Novalis {sup registered} system

    Energy Technology Data Exchange (ETDEWEB)

    Ernst-Stecken, A.; Sauer, R.; Grabenbauer, G. [Dept. of Radiation Therapy and Novalis Shaped Beam Surgery Center, Univ. Hospital of Erlangen-Nuremberg, Erlangen (Germany); Lambrecht, U.; Mueller, R. [Dept. of Radiation Therapy and Novalis Shaped Beam Surgery Center, Univ. Hospital of Erlangen-Nuremberg, Erlangen (Germany); Div. of Medical Physics, Dept. of Radiation Therapy, Univ. Hospital of Erlangen-Nuremberg, Erlangen (Germany); Ganslandt, O. [Dept. of Neurosurgery, Univ. of Erlangen-Nuremberg, Erlangen (Germany)

    2006-03-15

    Purpose: to evaluate the feasibility and tolerance of dose escalation with stereotactic intensity-modulated radiotherapy (sIMRT) for skull-base tumors. Patients and Methods: between 01/2003 and 12/2004, twelve patients were treated. Nine were exclusively treated at the Novalis {sup registered} site with one planning target volume (PTV) field boost, three were administered boost IMRT treatment (two with each one PTV-shrinking field, one with single PTV) after conventional three-dimensional conformal radiotherapy. This resulted in 23 PTVs with a median volume of 93.63 cm{sup 3} (range, 88.58-125.88 cm{sup 3}). Dose calculation was done by the pencil-beam algorithm. Median total doses of 66.6, 77.4, and 63.9 Gy were prescribed for sIMRT alone, sIMRT after 3-D conformal irradiation of the nasopharynx and cervical lymph nodes with 59.4 Gy, and for reirradiation, respectively. Results: 95% isodose PTV coverage was reached in 86.5% (range, 80-93%). Homogeneity (D{sub max}/D{sup ref}) was 1.11, 1.09, and 1.08. Median total doses to 50% of chiasm, right and left optic nerve were 16.21, 16.82 and 10.23 Gy. 11/12 patients are locally controlled with a median follow-up of 11 months (range, 3-23 months), one has died of pulmonary embolism after cerebrospinal dissemination of retinal adenocarcinoma. Conclusion: SIMRT enables dose escalation to tumors located close to critical organs. Inverse planning for micro-multileaf collimator stereotactic irradiation is practicable in the daily routine irradiation program. SIMRT needs special verification and still, the following parameters have to be standardized: IMRT dose specification, dose maxima, length of radiation delivery time. (orig.)

  3. Effects of rapid, high-dose, elevated temperature ion implantation on the microstructure and tribology of ferrous surfaces

    Science.gov (United States)

    Williamson, D. L.; Wei, R.; Wilbur, P. J.

    1991-05-01

    High-current, broad-beam ion implantation at 60 keV using a relatively simple system produces elevated target temperatures and results in remarkable enhancements in the wear resistance of ferrous materials compared to lower implantation temperatures. Effects of N, C and O implantation into AISI 304 stainless steel at 200 and 400°C on the microstructure and tribology are evaluated by conversion electron Mössbauer spectroscopy, X-ray diffraction, and a specially designed pin-on-disc tribotester. C and N implantation at 400°C yields unusually thick layers of austenite containing high concentrations of C and N in interstitial solid solution thereby accounting for the enhanced mechanical properties. O implantation at 400°C results in Fe 2O 3-like oxide rather than O in solid solution so a dispersion strengthening of the surface layer is suggested.

  4. Large-scale coherent structures of suspended dust concentration in the neutral atmospheric surface layer: A large-eddy simulation study

    Science.gov (United States)

    Zhang, Yangyue; Hu, Ruifeng; Zheng, Xiaojing

    2018-04-01

    Dust particles can remain suspended in the atmospheric boundary layer, motions of which are primarily determined by turbulent diffusion and gravitational settling. Little is known about the spatial organizations of suspended dust concentration and how turbulent coherent motions contribute to the vertical transport of dust particles. Numerous studies in recent years have revealed that large- and very-large-scale motions in the logarithmic region of laboratory-scale turbulent boundary layers also exist in the high Reynolds number atmospheric boundary layer, but their influence on dust transport is still unclear. In this study, numerical simulations of dust transport in a neutral atmospheric boundary layer based on an Eulerian modeling approach and large-eddy simulation technique are performed to investigate the coherent structures of dust concentration. The instantaneous fields confirm the existence of very long meandering streaks of dust concentration, with alternating high- and low-concentration regions. A strong negative correlation between the streamwise velocity and concentration and a mild positive correlation between the vertical velocity and concentration are observed. The spatial length scales and inclination angles of concentration structures are determined, compared with their flow counterparts. The conditionally averaged fields vividly depict that high- and low-concentration events are accompanied by a pair of counter-rotating quasi-streamwise vortices, with a downwash inside the low-concentration region and an upwash inside the high-concentration region. Through the quadrant analysis, it is indicated that the vertical dust transport is closely related to the large-scale roll modes, and ejections in high-concentration regions are the major mechanisms for the upward motions of dust particles.

  5. Computing the full spectrum of large sparse palindromic quadratic eigenvalue problems arising from surface Green's function calculations

    Science.gov (United States)

    Huang, Tsung-Ming; Lin, Wen-Wei; Tian, Heng; Chen, Guan-Hua

    2018-03-01

    Full spectrum of a large sparse ⊤-palindromic quadratic eigenvalue problem (⊤-PQEP) is considered arguably for the first time in this article. Such a problem is posed by calculation of surface Green's functions (SGFs) of mesoscopic transistors with a tremendous non-periodic cross-section. For this problem, general purpose eigensolvers are not efficient, nor is advisable to resort to the decimation method etc. to obtain the Wiener-Hopf factorization. After reviewing some rigorous understanding of SGF calculation from the perspective of ⊤-PQEP and nonlinear matrix equation, we present our new approach to this problem. In a nutshell, the unit disk where the spectrum of interest lies is broken down adaptively into pieces small enough that they each can be locally tackled by the generalized ⊤-skew-Hamiltonian implicitly restarted shift-and-invert Arnoldi (G⊤SHIRA) algorithm with suitable shifts and other parameters, and the eigenvalues missed by this divide-and-conquer strategy can be recovered thanks to the accurate estimation provided by our newly developed scheme. Notably the novel non-equivalence deflation is proposed to avoid as much as possible duplication of nearby known eigenvalues when a new shift of G⊤SHIRA is determined. We demonstrate our new approach by calculating the SGF of a realistic nanowire whose unit cell is described by a matrix of size 4000 × 4000 at the density functional tight binding level, corresponding to a 8 × 8nm2 cross-section. We believe that quantum transport simulation of realistic nano-devices in the mesoscopic regime will greatly benefit from this work.

  6. Three-dimensional conformal radiation may deliver considerable dose of incidental nodal irradiation in patients with early stage node-negative non-small cell lung cancer when the tumor is large and centrally located

    International Nuclear Information System (INIS)

    Zhao Lujun; Chen Ming; Haken, Randall ten; Chetty, Indrin; Chapet, Olivier; Hayman, James A.; Kong Fengming

    2007-01-01

    Background and purpose: To determine the dose to regional nodal stations in patients with T 1-3 N 0 M 0 non-small cell lung cancer (NSCLC) treated with three-dimensional conformal radiation therapy (3DCRT) without intentional elective nodal irradiation (ENI). Materials and methods: Twenty-three patients with medically inoperable T 1-3 N 0 M 0 NSCLC were treated with 3DCRT without ENI. Hilar and mediastinal nodal regions were contoured on planning CT. The prescription dose was normalized to 70 Gy. Equivalent uniform dose (EUD) and other dosimetric parameters (e.g., V 40 ) were calculated for each nodal station. Results: The median EUD for the whole group ranged from 0.4 to 4.4 Gy for all elective nodal regions. Gross tumor volume (GTV) and the relationship between GTV and hilum were significantly correlated with irradiation dose to ipsilateral hilar nodal regions (P 3 (diameter ∼ 4 cm) and or having any overlap with hilum, the median EUDs were 9.6, 22.6, and 62.9 Gy for ipsilateral lower paratracheal, subcarinal, and ipsilateral hilar regions, respectively. The corresponding median V 40 were 32.5%, 39.3%, and 97.6%, respectively. Conclusions: Although incidental nodal irradiation dose is low in the whole group, the dose to high-risk nodal regions is considerable in patients with T 1-3 N 0 NSCLC when the primary is large and/or centrally located

  7. Cationic lipid-formulated DNA vaccine against hepatitis B virus: immunogenicity of MIDGE-Th1 vectors encoding small and large surface antigen in comparison to a licensed protein vaccine.

    Directory of Open Access Journals (Sweden)

    Anne Endmann

    Full Text Available Currently marketed vaccines against hepatitis B virus (HBV based on the small (S hepatitis B surface antigen (HBsAg fail to induce a protective immune response in about 10% of vaccinees. DNA vaccination and the inclusion of PreS1 and PreS2 domains of HBsAg have been reported to represent feasible strategies to improve the efficacy of HBV vaccines. Here, we evaluated the immunogenicity of SAINT-18-formulated MIDGE-Th1 vectors encoding the S or the large (L protein of HBsAg in mice and pigs. In both animal models, vectors encoding the secretion-competent S protein induced stronger humoral responses than vectors encoding the L protein, which was shown to be retained mainly intracellularly despite the presence of a heterologous secretion signal. In pigs, SAINT-18-formulated MIDGE-Th1 vectors encoding the S protein elicited an immune response of the same magnitude as the licensed protein vaccine Engerix-B, with S protein-specific antibody levels significantly higher than those considered protective in humans, and lasting for at least six months after the third immunization. Thus, our results provide not only the proof of concept for the SAINT-18-formulated MIDGE-Th1 vector approach but also confirm that with a cationic-lipid formulation, a DNA vaccine at a relatively low dose can elicit an immune response similar to a human dose of an aluminum hydroxide-adjuvanted protein vaccine in large animals.

  8. Effects of upper-surface blowing and thrust vectoring on low-speed aerodynamic characteristics of a large-scale supersonic transport model

    Science.gov (United States)

    Coe, P. L., Jr.; Mclemore, H. C.; Shivers, J. P.

    1975-01-01

    Tests were conducted in the Langley full-scale tunnel to determine the low-speed aerodynamic characteristics of a large-scale arrow-wing supersonic transport configured with engines mounted above the wing for upper surface blowing, and conventional lower surface engines with provisions for thrust vectoring. A limited number of tests were conducted for the upper surface engine configuration in the high lift condition for beta = 10 in order to evaluate lateral directional characteristics, and with the right engine inoperative to evaluate the engine out condition.

  9. Recent Time Trends and Predictors of Heart Dose From Breast Radiation Therapy in a Large Quality Consortium of Radiation Oncology Practices.

    Science.gov (United States)

    Pierce, Lori J; Feng, Mary; Griffith, Kent A; Jagsi, Reshma; Boike, Thomas; Dryden, Daniel; Gustafson, Gregory S; Benedetti, Lisa; Matuszak, Martha M; Nurushev, Teamour S; Haywood, Joe; Radawski, Jeffrey D; Speers, Corey; Walker, Eleanor M; Hayman, James A; Moran, Jean M

    2017-12-01

    Limited data exist regarding the range of heart doses received in routine practice with radiation therapy (RT) for breast cancer in the United States today and the potential effect of the continual assessment of the cardiac dose on practice patterns. From 2012 to 2015, 4688 patients with breast cancer treated with whole breast RT at 20 sites participating in a state-wide consortium were enrolled into a registry. The importance of limiting the cardiac dose has been emphasized in the consortium since 2012, and the mean heart dose (MHD) has been reported by each institution since 2014. The effects on the MHD were estimated for both conventional and accelerated fractionation using regression models, with technique (intensity modulated RT [IMRT] vs 3-dimensional conformal RT), deep inspiration breath hold use, patient position (supine vs prone), nodal RT (if delivered), and boost (yes vs no) as covariates. For left-sided breast cancer treated with conventional fractionation, the median MHD in 2012 was 2.19 Gy versus 1.65 Gy in 2015 (Pinternal mammary nodal RT (40.7%), use of a boost (20.9%), treatment year before 2015 (7.7%), and use of IMRT (20.8%). For left-sided BC treated with accelerated fractionation, the median MHD in 2012 was 1.70 Gy versus 1.22 Gy in 2015 (Pradiation oncology community in general and a state-wide consortium specifically. These data suggest a positive effect of systematically monitoring the heart dose delivered. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Investigating the Impact of Surface Heterogeneity on the Convective Boundary Layer Over Urban Areas Through Coupled Large-Eddy Simulation and Remote Sensing

    Science.gov (United States)

    Dominguez, Anthony; Kleissl, Jan P.; Luvall, Jeffrey C.

    2011-01-01

    Large-eddy Simulation (LES) was used to study convective boundary layer (CBL) flow through suburban regions with both large and small scale heterogeneities in surface temperature. Constant remotely sensed surface temperatures were applied at the surface boundary at resolutions of 10 m, 90 m, 200 m, and 1 km. Increasing the surface resolution from 1 km to 200 m had the most significant impact on the mean and turbulent flow characteristics as the larger scale heterogeneities became resolved. While previous studies concluded that scales of heterogeneity much smaller than the CBL inversion height have little impact on the CBL characteristics, we found that further increasing the surface resolution (resolving smaller scale heterogeneities) results in an increase in mean surface heat flux, thermal blending height, and potential temperature profile. The results of this study will help to better inform sub-grid parameterization for meso-scale meteorological models. The simulation tool developed through this study (combining LES and high resolution remotely sensed surface conditions) is a significant step towards future studies on the micro-scale meteorology in urban areas.

  11. SU-E-T-96: Demonstration of a Consistent Method for Correcting Surface Dose Measurements Using Both Solid State and Ionization Chamber Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Reynolds, T; Gerbi, B; Higgins, P [UniversityMinnesota, Minneapolis, MN (United States)

    2014-06-01

    Purpose: To compare the surface dose (SD) measured using a PTW 30-360 extrapolation chamber with different commonly used dosimeters (Ds): parallel plate ion chambers (ICs): RMI-449 (Attix), Capintec PS-033, PTW 30-329 (Markus) and Memorial; TLD chips (cTLD), TLD powder (pTLD), optically stimulated (OSLs), radiochromic (EXR2) and radiographic (EDR2) films, and to provide an intercomparison correction to Ds for each of them. Methods: Investigations were performed for a 6 MV x-ray beam (Varian Clinac 2300, 10x10 cm{sup 2} open field, SSD = 100 cm). The Ds were placed at the surface of the solid water phantom and at the reference depth dref=1.7cm. The measurements for cTLD, OSLs, EDR2 and EXR2 were corrected to SD using an extrapolation method (EM) indexed to the baseline PTW 30-360 measurements. A consistent use of the EM involved: 1) irradiation of three Ds stacked on top of each other on the surface of the phantom; 2) measurement of the relative dose value for each layer; and, 3) extrapolation of these values to zero thickness. An additional measurement was performed with externally exposed OSLs (eOSLs), that were rotated out of their protective housing. Results: All single Ds measurements overestimated the SD compared with the extrapolation chamber, except for Attix IC. The closest match to the true SD was measured with the Attix IC (− 0.1%), followed by pTLD (0.5%), Capintec (4.5%), Memorial (7.3%), Markus (10%), cTLD (11.8%), eOSL (12.8%), EXR2 (14%), EDR2 (14.8%) and OSL (26%). The EM method of correction for SD worked well for all Ds, except the unexposed OSLs. Conclusion: This EM cross calibration of solid state detectors with an extrapolation or Attix chamber can provide thickness corrections for cTLD, eOSLs, EXR2, and EDR2. Standard packaged OSLs were not found to be simply corrected.

  12. Digital radiography of the skeleton using a large-area detector based on amorphous silicon technology: Image quality and potential for dose reduction in comparison with screen-film radiography

    International Nuclear Information System (INIS)

    Volk, M.; Strotzer, M.; Holzkneckt, N.; Manke, C.; Lenhart, M.; Gmeinwieser, J.; Link, J.; Reiser, M.; Feuerback, S.

    2000-01-01

    AIM: The purpose of this study was to evaluate a large-area, flat-panel X-ray detector (FD), based on caesium-iodide (CsI) and amorphous silicon (a-Si) with respect to skeletal radiography. Conventional images were compared with digital radiographs using identical and reduced radiation doses. MATERIALS AND METHODS: Thirty consecutive patients were studied prospectively using conventional screen-film radiography (SFR; detector dose 2.5 μGy). Digital images were taken from the same patients with detector doses of 2.5, 1.25 and 0.625 μGy, respectively. The active-matrix detector had a panel size of 43 x 43 cm, a matrix of 3 x 3K, and a pixel size of 143 μm. All hard copies were presented in a random order to eight independent observers, who rated image quality according to subjective quality criteria. Results were assessed for significance using the Student's t -test (confidence level 95%). RESULTS: A statistically significant preference for digital over conventional images was revealed for all quality criteria, except for over-exposure (detector dose 2.5 μGy). Digital images with a 50% dose showed a small, statistically not significant, inferiority compared with SFR. The FD-technique was significantly inferior to SFR at 75% dose reduction regarding bone cortex and trabecula, contrast and overall impression. No statistically significant differences were found with regard to over- and under-exposure and soft tissue presentation. CONCLUSION: Amorphous silicon-based digital radiography yields good image quality. The potential for dose reduction depends on the clinical query. Volk, M. (2000)

  13. The "AQUASCOPE" simplified model for predicting 89, 90Sr, 131l and 134, 137Cs in surface waters after a large-scale radioactive fallout

    NARCIS (Netherlands)

    Smith, J.T.; Belova, N.V.; Bulgakov, A.A.; Comans, R.N.J.; Konoplev, A.V.; Kudelsky, A.V.; Madruga, M.J.; Voitsekhovitch, O.V.; Zibolt, G.

    2005-01-01

    Simplified dynamic models have been developed for predicting the concentrations of radiocesium, radiostrontium, and 131I in surface waters and freshwater fish following a large-scale radioactive fallout. The models are intended to give averaged estimates for radionuclides in water bodies and in fish

  14. Dedicated Tool for Irradiation and Electrical Measurement of Large Surface Samples on the Beamline of a 2.5 Mev Pelletron Electron Accelerator: Application to Solar Cells

    Directory of Open Access Journals (Sweden)

    Lefèvre Jérémie

    2017-01-01

    After a brief description of the SIRIUS irradiation facility hosted at Laboratoire des Solides Irradiés (LSI, this paper gives detailed information about the Large Surface Irradiated-Cell (LSIC device. Preliminary results obtained during the ongoing qualification phase of the setup are also discussed.

  15. Wind-tunnel investigation of aerodynamic performance, steady amd vibratory loads, surface temperatures, and acoustic characteristics of a large-scale twin-engine upper-surface blown jet-flap configuration

    Science.gov (United States)

    1976-01-01

    Static and wind-on tests were conducted to determine the aerodynamic characteristics of and the effects of jet impingement on the wing of a large scale upper surface blown configuration powered with an actual turbine engine. The wing and flaps were instrumented with experimental dual-sensing transducer units consisting of a fluctuating pressure gage, a vibratory accelerometer, and a surface mounted alumel thermocouple. Noise directivity and spectral content measurements were obtained for various flap configurations and various engine thrust settings to provide baseline noise data for other upper surface blown configurations.

  16. Large-Area Direct Laser-Shock Imprinting of a 3D Biomimic Hierarchical Metal Surface for Triboelectric Nanogenerators.

    Science.gov (United States)

    Jin, Shengyu; Wang, Yixiu; Motlag, Maithilee; Gao, Shengjie; Xu, Jin; Nian, Qiong; Wu, Wenzhuo; Cheng, Gary J

    2018-03-01

    Ongoing efforts in triboelectric nanogenerators (TENGs) focus on enhancing power generation, but obstacles concerning the economical and cost-effective production of TENGs continue to prevail. Micro-/nanostructure engineering of polymer surfaces has been dominantly utilized for boosting the contact triboelectrification, with deposited metal electrodes for collecting the scavenged energy. Nevertheless, this state-of-the-art approach is limited by the vague potential for producing 3D hierarchical surface structures with conformable coverage of high-quality metal. Laser-shock imprinting (LSI) is emerging as a potentially scalable approach for directly surface patterning of a wide range of metals with 3D nanoscale structures by design, benefiting from the ultrahigh-strain-rate forming process. Here, a TENG device is demonstrated with LSI-processed biomimetic hierarchically structured metal electrodes for efficient harvesting of water-drop energy in the environment. Mimicking and transferring hierarchical microstructures from natural templates, such as leaves, into these water-TENG devices is effective regarding repelling water drops from the device surface, since surface hydrophobicity from these biomicrostructures maximizes the TENG output. Among various leaves' microstructures, hierarchical microstructures from dried bamboo leaves are preferable regarding maximizing power output, which is attributed to their unique structures, containing both dense nanostructures and microscale features, compared with other types of leaves. Also, the triboelectric output is significantly improved by closely mimicking the hydrophobic nature of the leaves in the LSI-processed metal surface after functionalizing it with low-surface-energy self-assembled-monolayers. The approach opens doors to new manufacturable TENG technologies for economically feasible and ecologically friendly production of functional devices with directly patterned 3D biomimic metallic surfaces in energy

  17. Are Trends in Total Hip Arthroplasty Bearing Surface Continuing to Change? 2007-2015 Usage in a Large Database Cohort.

    Science.gov (United States)

    Bedard, Nicholas A; Burnett, Robert A; DeMik, David E; Gao, Yubo; Liu, Steve S; Callaghan, John J

    2017-12-01

    Bearing surface issues related to trunnionosis or metal-on-metal (MoM) articulations have likely impacted recent trends in bearing surface choice. The purpose of this study is to evaluate trends in total hip arthroplasty (THA) bearing surface use, including 2015 data, with respect to the date of operation and patient demographics. The Humana dataset was reviewed from 2007 through 2015 to analyze bearing surface usage in primary THA. Four bearing surface types were identified by International Classification of Disease, 10th Revision codes and trended throughout the years: metal-on-polyethylene (MoP), ceramic-on-ceramic (CoC), ceramic-on-polyethylene (CoP), and MoM. Prevalence was analyzed as a function of age and sex. Of the 28,504 primary THA procedures, the most commonly used bearing was MoP (46.1%), followed by CoP (33.2%), MoM (17.1%), and ceramic-on-ceramic (3.6%). The use of CoP bearings significantly increased from 6.4% in 2007 to 52.0% in 2015, while MoM bearings decreased during this period. MoP bearings decreased over 2012-2015 (P bearings increased with a transition occurring at 65-69 years of age. Women were more likely to receive MoP bearings (odds ratio [OR] 1.2), while men were more likely to receive MoM and CoP bearings (OR 1.1). Multivariate logistic regression showed age to be an independent predictor of bearing surface choice with patients 65 and older more likely to receive MoP bearings (OR 3.2). Bearing surface choice in primary THA has changed tremendously from 2007 to 2015. MoM bearing use has decreased as a result of adverse effects. Age continues to remain a significant factor in bearing surface choice. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. The sensitivity of the large-scale atmosphere circulation to changes in surface temperature gradients in the Northern Hemisphere

    NARCIS (Netherlands)

    Molnos, Sonja; Petri, Stefan; Lehmann, Jascha; Peukert, Erik; Coumou, Dim

    2017-01-01

    Climate and weather conditions in the mid-latitudes are strongly driven by the large-scale atmosphere circulation. Observational data indicates that important components of the large-scale circulation have changed in recent decades including the strength of the Hadley cell, jet streams, storm tracks

  19. Long-Term Remission of Primary Bone Marrow Diffuse Large B-Cell Lymphoma Treated with High-Dose Chemotherapy Rescued by In Vivo Rituximab-Purged Autologous Stem Cells

    OpenAIRE

    Kazama, Hiroshi; Teramura, Masanao; Yoshinaga, Kentaro; Masuda, Akihiro; Motoji, Toshiko

    2012-01-01

    Primary bone marrow diffuse large B-cell lymphoma (DLBCL) is a rare type of extranodal lymphoma with poor prognosis. Here, we report a case of primary bone marrow DLBCL successfully treated with high-dose chemotherapy and rescued by in vivo rituximab-purged autologous stem cells. A 39-year-old woman visited our hospital because of anemia. Bone marrow examination revealed a large B-cell lymphoma invasion. An 18F-fluorodeoxyglucose positron emission tomography scan revealed disseminated bone ma...

  20. Surface clay formation during short-term warmer and wetter conditions on a largely cold ancient Mars

    Science.gov (United States)

    Bishop, Janice L.; Fairén, Alberto G.; Michalski, Joseph R.; Gago-Duport, Luis; Baker, Leslie L.; Velbel, Michael A.; Gross, Christoph; Rampe, Elizabeth B.

    2018-03-01

    The ancient rock record for Mars has long been at odds with climate modelling. The presence of valley networks, dendritic channels and deltas on ancient terrains points towards running water and fluvial erosion on early Mars1, but climate modelling indicates that long-term warm conditions were not sustainable2. Widespread phyllosilicates and other aqueous minerals on the Martian surface3-6 provide additional evidence that an early wet Martian climate resulted in surface weathering. Some of these phyllosilicates formed in subsurface crustal environments5, with no association with the Martian climate, while other phyllosilicate-rich outcrops exhibit layered morphologies and broad stratigraphies7 consistent with surface formation. Here, we develop a new geochemical model for early Mars to explain the formation of these clay-bearing rocks in warm and wet surface locations. We propose that sporadic, short-term warm and wet environments during a generally cold early Mars enabled phyllosilicate formation without requiring long-term warm and wet conditions. We conclude that Mg-rich clay-bearing rocks with lateral variations in mixed Fe/Mg smectite, chlorite, talc, serpentine and zeolite occurrences formed in subsurface hydrothermal environments, whereas dioctahedral (Al/Fe3+-rich) smectite and widespread vertical horizonation of Fe/Mg smectites, clay assemblages and sulphates formed in variable aqueous environments on the surface of Mars. Our model for aluminosilicate formation on Mars is consistent with the observed geological features, diversity of aqueous mineralogies in ancient surface rocks and state-of-the-art palaeoclimate scenarios.

  1. Finite Element Methods On Very Large, Dynamic Tubular Grid Encoded Implicit Surfaces

    DEFF Research Database (Denmark)

    Nemitz, Oliver; Nielsen, Michael Bang; Rumpf, Martin

    2009-01-01

    The simulation of physical processes on interfaces and a variety of applications in geometry processing and geometric modeling are based on the solution of partial differential equations on curved and evolving surfaces. Frequently, an implicit level set type representation of these surfaces...... on the boundary of the narrow band and a nested iteration scheme in each time step are investigated. This nested iteration scheme enables the discrete interfaces to move in a single time step significantly beyond the domain of the narrow band of the previous time step. Furthermore, algorithmic tools are provided...

  2. Modeling the large-scale effects of surface moisture heterogeneity on wetland carbon fluxes in the West Siberian Lowland

    Directory of Open Access Journals (Sweden)

    T. J. Bohn

    2013-10-01

    Full Text Available We used a process-based model to examine the role of spatial heterogeneity of surface and sub-surface water on the carbon budget of the wetlands of the West Siberian Lowland over the period 1948–2010. We found that, while surface heterogeneity (fractional saturated area had little overall effect on estimates of the region's carbon fluxes, sub-surface heterogeneity (spatial variations in water table depth played an important role in both the overall magnitude and spatial distribution of estimates of the region's carbon fluxes. In particular, to reproduce the spatial pattern of CH4 emissions recorded by intensive in situ observations across the domain, in which very little CH4 is emitted north of 60° N, it was necessary to (a account for CH4 emissions from unsaturated wetlands and (b use spatially varying methane model parameters that reduced estimated CH4 emissions in the northern (permafrost half of the domain (and/or account for lower CH4 emissions under inundated conditions. Our results suggest that previous estimates of the response of these wetlands to thawing permafrost may have overestimated future increases in methane emissions in the permafrost zone.

  3. Estimation of dependence between mean of fractionation of photons and neutrons dose and intensity of post-irradiation reaction of mouse large intestine; Ocena zaleznosci pomiedzy sposobem frakcjonowania dawki fotonow i neutronow a nasileniem popromiennego odczynu jelita grubego myszy

    Energy Technology Data Exchange (ETDEWEB)

    Gasinska, A. [Oncology Center, Cracow (Poland)

    1995-12-31

    The aim of the work was verification of mouse large intestine tolerance on fractionated 250 kV X-rays and 2.3 MeV neutrons doses. Two cm of large intestine of mouse CBA/HT strain were irradiated with various fraction doses: from 0.25 to 35 Gy of X-rays and 0.05-12 Gy of neutrons. The measure of injury was handicap of intestine function. Early post-irradiation reaction was measured by loss of body weight (2-3 weeks after irradiation) and mouse mortality (till 2 months after irradiation, LD50/2). The late reaction was measured on the base of maximal body weight in 1 year period after irradiation, deformation of excrements (after 10 months) and death of animals (till 12. month after irradiation, LD50/12). Fractionation of X-ray dose influenced on decrease of intensification of late irradiation effects. After fractionation of neutrons this effect has not been observed. {alpha}/{beta} coefficient for X-rays was 19.9 Gy [15.2; 27.0] for body weight nadir, 13.4 Gy [9.3; 19.5] for early mortality (LD50/2), 6.4 Gy [3.6;11.0] for maximal body weight and 6.9 [4.2; 10.8] for late mortality (LD50/12). Analysis of influence of low doses of photons 90.25-4 Gy) and neutrons (0.05-0.8 Gy) showed trend to reduction {alpha}/{beta} for photons only (LD50/2=5.4 Gy; LD50/12=4.6 Gy). {alpha}/{beta} coefficient for neutrons was defined by LQ model only for maximal body weight and was 19.9 Gy [9.5; 61.0]. In application of graphic method {alpha}/{beta} for neutrons was 230 Gy for early and 48 Gy for late effects. Lower values of {alpha}/{beta} coefficient for late irradiation effects for photon radiation demonstrate the big influence of fractionation of photons dose on large intestine tolerance (decrease intensity in all biological effects). Author did not observe increase of intestine tolerance in fractionation of neutrons dose. Effect of irradiation damages repair in interfraction pauses, measured by percent of regenerated dose (F{sub r}) was much bigger for photons. For X-rays it was 50

  4. Development and Application of Blast Casting Technique in Large-Scale Surface Mines: A Case Study of Heidaigou Surface Coal Mine in China

    Directory of Open Access Journals (Sweden)

    Li Ma

    2016-01-01

    Full Text Available Blast casting is a high-efficiency technique applied in surface mines for overburden removal and results in stripping cost savings. According to ballistic theory and center-of-mass frame basic movement principles, key factors influencing blast casting effect were analyzed, which include bench height and mining panel width, inclined angle of blast holes, explosive unit consumption (EUC, delay-time interval, presplitting, and blast hole pattern parameters. An intelligent design software was developed for obtaining better breaking and casting effect, and the error rates predicted with actual result can be controlled with 10%. Blast casting technique was successfully applied in Heidaigou Surface Coal Mine (HSCM with more than 34% of material casted into the inner dump. A ramp ditch was set within the middle inner dump for coal transportation. The procedure of stripping and excavating was implemented separately and alternately in the two sections around the middle ramp ditch. An unconstrained-nonlinear model was deduced for optimizing the shift distance of the middle ramp. The calculation results show that optimum shift distance of HSCM is 480 m, and the middle ditch should be shifted after 6 blast casting mining panels being stripped.

  5. Rapid and large-scale synthesis of pitaya-like silver nanostructures as highly efficient surface-enhanced Raman scattering substrates.

    Science.gov (United States)

    Huang, Qingli; Zhu, Xiashi

    2013-02-15

    A new wet-chemical approach to prepare surface-enhanced Raman scattering (SERS)-active substrates with pitaya-like silver nanostructures (PSNs) was proposed. It has been found that the morphology of as-prepared products is dependent on the reaction parameters. PSNs exhibit a high detection sensitivity of surface-enhanced Raman scattering for Rhodamine 6G (R6G) with a limit of detection of 1.0 × 10(-13) mol L(-1). This facile, large-scale, low-cost, and green chemistry synthesized Ag nanostructures make it a perfect choice for practical SERS detection applications. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Analysis of the Effect of Chronic and Low-Dose Radiation Exposure on Spermatogenic Cells of Male Large Japanese Field Mice ( Apodemus speciosus ) after the Fukushima Daiichi Nuclear Power Plant Accident.

    Science.gov (United States)

    Takino, Sachio; Yamashiro, Hideaki; Sugano, Yukou; Fujishima, Yohei; Nakata, Akifumi; Kasai, Kosuke; Hayashi, Gohei; Urushihara, Yusuke; Suzuki, Masatoshi; Shinoda, Hisashi; Miura, Tomisato; Fukumoto, Manabu

    2017-02-01

    In this study we analyzed the effect of chronic and low-dose-rate (LDR) radiation on spermatogenic cells of large Japanese field mice ( Apodemus speciosus ) after the Fukushima Daiichi Nuclear Power Plant (FNPP) accident. In March 2014, large Japanese field mice were collected from two sites located in, and one site adjacent to, the FNPP ex-evacuation zone: Tanashio, Murohara and Akogi, respectively. Testes from these animals were analyzed histologically. External dose rate from radiocesium (combined 134 Cs and 137 Cs) in these animals at the sampling sites exhibited 21 μGy/day in Tanashio, 304-365 μGy/day in Murohara and 407-447 μGy/day in Akogi. In the Akogi group, the numbers of spermatogenic cells and proliferating cell nuclear antigen (PCNA)-positive cells per seminiferous tubule were significantly higher compared to the Tanashio and Murohara groups, respectively. TUNEL-positive apoptotic cells tended to be detected at a lower level in the Murohara and Akogi groups compared to the Tanashio group. These results suggest that enhanced spermatogenesis occurred in large Japanese field mice living in and around the FNPP ex-evacuation zone. It remains to be elucidated whether this phenomenon, attributed to chronic exposure to LDR radiation, will benefit or adversely affect large Japanese field mice.

  7. [Induction of biological protection in pigs against infection with Aujeszky disease virus by vaccination with large doses of live or inactivated vaccines].

    Science.gov (United States)

    Zuffa, A

    1986-02-01

    Pigs were inoculated against the Aujeszky's disease twice in a four-week interval. The dose of the live vaccine was 10(6) TKID50 and the titres of neutralizing antibodies were 1 : 16 to 1 : 128 in blood serum. Two weeks later the pigs were exposed to contact infection. Primary multiplication of the virus was observed on the mucous membranes of the nose and oropharynx and the virus was detected on the nasal mucous membrane within one to five days, the maximum infection titre values being 10(1.3) TKID50, and on the oropharyngeal mucous membrane within seven days, the maximum titres being up to 10(3.5) TKID50. In another group the pigs were inoculated with the same dose of attenuated virus or re-vaccinated with a dose of 10(8.5) TKID50, with neutralizing antibody titres of 1 : 256 to 1 : 1024 in blood serum. No viruses were detected on the nasal mucous membrane after contact infection and only trace amounts of the virus were found in the oropharynx within one to five days. Six piglets were inoculated in the same way but the infection was intranasal. The infective virus was detected on the nasal mucous membrane of only one piglet; however, trace amounts of the virus were found in the oropharynx of all the six piglets within three to nine days after infection. The nasal mucous membrane and oropharynx of the noninoculated control piglets exposed to intranasal infection were infectious until death and those of the contact-infected piglets remained so until the 14th day. At the intranasal infection of the piglets infected twice with a live or inactivated vaccine and slaughtered the 1st to 14th day after intranasal infection, the virus was replicated only in the place of primary multiplication without penetrating into the CNS and the internal organs. The intranasal infection of susceptible control piglets resulted in the dissemination of the infection via the neurogenic and lymphohaematogenic routes.

  8. Radiation transport simulation of the Martian GCR surface flux and dose estimation using spherical geometry in PHITS compared to MSL-RAD measurements.

    Science.gov (United States)

    Flores-McLaughlin, John

    2017-08-01

    Planetary bodies and spacecraft are predominantly exposed to isotropic radiation environments that are subject to transport and interaction in various material compositions and geometries. Specifically, the Martian surface radiation environment is composed of galactic cosmic radiation, secondary particles produced by their interaction with the Martian atmosphere, albedo particles from the Martian regolith and occasional solar particle events. Despite this complex physical environment with potentially significant locational and geometric dependencies, computational resources often limit radiation environment calculations to a one-dimensional or slab geometry specification. To better account for Martian geometry, spherical volumes with respective Martian material densities are adopted in this model. This physical description is modeled with the PHITS radiation transport code and compared to a portion of measurements from the Radiation Assessment Detector of the Mars Science Laboratory. Particle spectra measured between 15 November 2015 and 15 January 2016 and PHITS model results calculated for this time period are compared. Results indicate good agreement between simulated dose rates, proton, neutron and gamma spectra. This work was originally presented at the 1st Mars Space Radiation Modeling Workshop held in 2016 in Boulder, CO. Copyright © 2017. Published by Elsevier Ltd.

  9. Method of producing the arched surfaces of diaphragm rings for large containers, especially for prestressed-concrete pressure vessels of nuclear reactors

    International Nuclear Information System (INIS)

    Kumpf, H.

    1976-01-01

    In producing arched surfaces of diaphragm rings for large containers, especially for prestressed-concrete pressure vessels for nuclear power plants, it is of advantage to manufacture these directly on the construction site. According to the invention the, at first level, diaphragm ring is put on the predetermined place, sectionally pressed against and shaped by a shaping tool - with a profiled supporting ring as a counter-acting tool - and afterwards welded together with the annular wall sections of the large container along the shaped parts. The manufacture of single and double configurations of diaphragm rings is described. It is of advantage if shaping and mounting position coincide. (UWI) [de

  10. Surface gravity wave effects in the oceanic boundary layer: large-eddy simulation with vortex force and stochastic breakers

    Science.gov (United States)

    Sullivan, Peter P.; McWilliams, James C.; Melville, W. Kendall

    The wind-driven stably stratified mid-latitude oceanic surface turbulent boundary layer is computationally simulated in the presence of a specified surface gravity-wave field. The gravity waves have broad wavenumber and frequency spectra typical of measured conditions in near-equilibrium with the mean wind speed. The simulation model is based on (i) an asymptotic theory for the conservative dynamical effects of waves on the wave-averaged boundary-layer currents and (ii) a boundary-layer forcing by a stochastic representation of the impulses and energy fluxes in a field of breaking waves. The wave influences are shown to be profound on both the mean current profile and turbulent statistics compared to a simulation without these wave influences and forced by an equivalent mean surface stress. As expected from previous studies with partial combinations of these wave influences, Langmuir circulations due to the wave-averaged vortex force make vertical eddy fluxes of momentum and material concentration much more efficient and non-local (i.e. with negative eddy viscosity near the surface), and they combine with the breakers to increase the turbulent energy and dissipation rate. They also combine in an unexpected positive feedback in which breaker-generated vorticity seeds the creation of a new Langmuir circulation and instigates a deep strong intermittent downwelling jet that penetrates through the boundary layer and increases the material entrainment rate at the base of the layer. These wave effects on the boundary layer are greater for smaller wave ages and higher mean wind speeds.

  11. Sensitivity Analysis of the Surface Runoff Coefficient of HiPIMS in Simulating Flood Processes in a Large Basin

    Directory of Open Access Journals (Sweden)

    Yueling Wang

    2018-03-01

    Full Text Available To simulate flood processes at the basin level, the GPU-based High-Performance Integrated Hydrodynamic Modelling System (HiPIMS is gaining interest as computational capability increases. However, the difficulty of coping with rainfall input to HiPIMS reduces the possibility of acquiring a satisfactory simulation accuracy. The objective of this study is to test the sensitivity of the surface runoff coefficient in the HiPIMS source term in the Misai basin with an area of 797 km2 in south China. To achieve this, the basin was divided into 909,824 grid cells, to each of which a Manning coefficient was assigned based on its land use type interpreted from remote sensing data. A sensitivity analysis was conducted for three typical flood processes under four types of surface runoff coefficients, assumed a priori, upon three error functions. The results demonstrate the crucial role of the surface runoff coefficient in achieving better simulation accuracy and reveal that this coefficient varies with flood scale and is unevenly distributed over the basin.

  12. Replication fidelity assessment of polymer large area sub-μm structured surfaces using fast angular intensity distribution measurements

    DEFF Research Database (Denmark)

    Calaon, M.; Hansen, H. N.; Tosello, G.

    The present investigation addresses one of the key challenges in the product quality control of transparent polymer substrates, identified in the replication fidelity of sub-μm structures over large area. Additionally the work contributes to the development of new techniques focused on in-line ch...

  13. Mating competitiveness of male Anopheles arabiensis mosquitoes irradiated with a partially or fully sterilizing dose in small and large laboratory cages

    NARCIS (Netherlands)

    Helinski, M.; Knols, B.G.J.

    2008-01-01

    Male mating competitiveness is a crucial parameter in many genetic control programs including the sterile insect technique (SIT). We evaluated competitiveness of male Anopheles arabiensis Patton as a function of three experimental variables: (1) small or large cages for mating, (2) the effects of

  14. Quantifying Hyporheic Exchanges in a Large Scale River Reach Using Coupled 3-D Surface and Subsurface Computational Fluid Dynamics Simulations.

    Energy Technology Data Exchange (ETDEWEB)

    Hammond, Glenn Edward; Bao, J; Huang, M; Hou, Z; Perkins, W; Harding, S; Titzler, S; Ren, H; Thorne, P; Suffield, S; Murray, C; Zachara, J

    2017-03-01

    Hyporheic exchange is a critical mechanism shaping hydrological and biogeochemical processes along a river corridor. Recent studies on quantifying the hyporheic exchange were mostly limited to local scales due to field inaccessibility, computational demand, and complexity of geomorphology and subsurface geology. Surface flow conditions and subsurface physical properties are well known factors on modulating the hyporheic exchange, but quantitative understanding of their impacts on the strength and direction of hyporheic exchanges at reach scales is absent. In this study, a high resolution computational fluid dynamics (CFD) model that couples surface and subsurface flow and transport is employed to simulate hyporheic exchanges in a 7-km long reach along the main-stem of the Columbia River. Assuming that the hyporheic exchange does not affect surface water flow conditions due to its negligible magnitude compared to the volume and velocity of river water, we developed a one-way coupled surface and subsurface water flow model using the commercial CFD software STAR-CCM+. The model integrates the Reynolds-averaged Navier-Stokes (RANS) equation solver with a realizable κ-ε two-layer turbulence model, a two-layer all y+ wall treatment, and the volume of fluid (VOF) method, and is used to simulate hyporheic exchanges by tracking the free water-air interface as well as flow in the river and the subsurface porous media. The model is validated against measurements from acoustic Doppler current profiler (ADCP) in the stream water and hyporheic fluxes derived from a set of temperature profilers installed across the riverbed. The validated model is then employed to systematically investigate how hyporheic exchanges are influenced by surface water fluid dynamics strongly regulated by upstream dam operations, as well as subsurface structures (e.g. thickness of riverbed and subsurface formation layers) and hydrogeological properties (e.g. permeability). The results

  15. Paediatric dose display

    International Nuclear Information System (INIS)

    Griffin, D.W.; Derges, S.; Hesslewood, S.

    1984-01-01

    A compact, inexpensive unit, based on an 8085 microprocessor, has been designed for calculating doses of intravenous radioactive injections for children. It has been used successfully for over a year. The dose is calculated from the body surface area and the result displayed in MBq. The operator can obtain the required dose on a twelve character alphanumeric display by entering the age of the patient and the adult dose using a hexadecimal keyboard. Circuit description, memory map and input/output, and firmware are dealt with. (U.K.)

  16. Printed Large-Area Single-Mode Photonic Crystal Bandedge Surface-Emitting Lasers on Silicon (Open Access Publisher’s Version)

    Science.gov (United States)

    2016-01-04

    beam shape, catastrophic optical damage free, and two-dimensional integration capabilities with CMOS electronics , vertical-cavity surface-emitting...longitudinal and transverse mode over a large lasing area , narrow linewidth, high power output, small beam divergence angle, polarization control...crystal lasers—ultimate nanolasers and broad - area coherent lasers [Invited]. J. Opt. Soc. Am. B 27, B1–B8 (2010). 13. Painter, O. et al. Two-dimensional

  17. Effects of upper-surface blowing and thrust vectoring on low speed aerodynamic characteristics of a large-scale supersonic transport model

    Science.gov (United States)

    Coe, P. L., Jr.; Mclemore, H. C.; Shivers, J. P.

    1976-01-01

    Tests were conducted in a full scale tunnel to determine the low speed aerodynamic characteristics of a large scale arrow wing supersonic transport configured with engines mounted above the wing for upper surface blowing and conventional lower surface engines having provisions for thrust vectoring. Tests were conducted over an angle of attack range of -10 deg to 34 deg and for Reynolds numbers (based on the mean aerodynamic chord) of 5.17 x 1 million and 3.89 x 1 million. A limited number of tests were also conducted for the upper surface engine configuration in the high lift condition at an angle of sideslip of 10 deg in order to evaluate lateral directional characteristics and with the right engine inoperative in order to evaluate the engine out condition.

  18. Large Scale Automatic Analysis and Classification of Roof Surfaces for the Installation of Solar Panels Using a Multi-Sensor Aerial Platform

    Directory of Open Access Journals (Sweden)

    Luis López-Fernández

    2015-09-01

    Full Text Available A low-cost multi-sensor aerial platform, aerial trike, equipped with visible and thermographic sensors is used for the acquisition of all the data needed for the automatic analysis and classification of roof surfaces regarding their suitability to harbor solar panels. The geometry of a georeferenced 3D point cloud generated from visible images using photogrammetric and computer vision algorithms, and the temperatures measured on thermographic images are decisive to evaluate the areas, tilts, orientations and the existence of obstacles to locate the optimal zones inside each roof surface for the installation of solar panels. This information is complemented with the estimation of the solar irradiation received by each surface. This way, large areas may be efficiently analyzed obtaining as final result the optimal locations for the placement of solar panels as well as the information necessary (location, orientation, tilt, area and solar irradiation to estimate the productivity of a solar panel from its technical characteristics.

  19. Is subterranean lifestyle reversible? Independent and recent large-scale dispersal into surface waters by two species of the groundwater amphipod genus Niphargus.

    Science.gov (United States)

    Copilaş-Ciocianu, Denis; Fišer, Cene; Borza, Péter; Petrusek, Adam

    2018-02-01

    Groundwater is an extreme environment due to its absence of light, resource scarcity and highly fragmentary nature. Successful groundwater colonizers underwent major evolutionary changes and exhibit eye and pigment loss (troglomorphies). Consequently, their chances of dispersal and survival in the well-connected surface waters are greatly decreased, resulting in significant endemism. The West Palaearctic subterranean amphipod genus Niphargus comprises hundreds of narrowly endemic and troglomorphic species. Nevertheless, a few are known to occur in surface waters, two of which, N. hrabei and N. valachicus, have extremely large ranges that even exceed those of many surface-water amphipods. We tested if this pattern results from a secondary colonization of the relatively well-connected epigean environment, and whether this ecological shift promoted the large-scale dispersal of these species. Results showed that despite their ecological and zoogeographic similarities, N. hrabei and N. valachicus are not closely related and independently colonized surface waters. Their phylogeographic patterns indicate Middle to Late Pleistocene dispersal episodes throughout the Danube lowlands, and relatively modest yet significant genetic differentiation among populations. Clustering based on morphology revealed that the two species are phenotypically closer to each other than they are to most other epigean congeners. We presume that the ecological shift to surface environments was facilitated by their ability to thrive in hypoxic waters where rheophilic competitors from the family Gammaridae cannot survive. In conclusion, our results indicate that adaptation to groundwater is not a one-way evolutionary path and that troglomorphic species can occasionally recolonize and widely disperse in surface waters. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Surface-Enhanced Raman Spectroscopy Based Quantitative Bioassay on Aptamer-Functionalized Nanopillars Using Large-Area Raman Mapping

    DEFF Research Database (Denmark)

    Yang, Jaeyoung; Palla, Mirko; Bosco, Filippo

    2013-01-01

    Surface-enhanced Raman spectroscopy (SERS) has been used in a variety of biological applications due to its high sensitivity and specificity. Here, we report a SERS-based biosensing approach for quantitative detection of biomolecules. A SERS substrate bearing gold-decorated silicon nanopillars......-to-spot variation in conventional SERS quantification. Furthermore, we have developed an analytical model capable of predicting experimental intensity distributions on the substrates for reliable quantification of biomolecules. Lastly, we have calculated the minimum needed area of Raman mapping for efficient...

  1. Large-scale, Lithography-free Production of Transparent Nanostructured Surface for Dual-functional Electrochemical and SERS Sensing

    DEFF Research Database (Denmark)

    Sanger, Kuldeep; Durucan, Onur; Wu, Kaiyu

    2017-01-01

    aspect ratios distributed homogeneously on a 4-inch fused silica wafer. The sensor was made up of three-electrode array, obtained by subsequent e-beam evaporation of Au on nanostructures in selected areas through a shadow mask. The SERS performance was evaluated through surface-averaged enhancement......-reversible behavior with decrease in peak potential separation (∆Ep ~90mV) and higher peak currents (Ipa/Ipc ~1), comparing to planar electrodes (∆Ep ~560mV). The oxidation potential of PAR was also lowered by ~80 mV on nanostructured electrodes. To illustrate dual-functional sensing, quantitative evaluation of PAR...

  2. [First experience of using modified high-dose therapy NHL-BFM-90 in diffuse large B-cell lymphosarcoma with primary skin involvement. A case report].

    Science.gov (United States)

    Zamiatina, V I; Magomedova, A U; Kravchenko, S K; Giliazitdinova, E A; Iliushkina, E A; Zvonkov, E E; Kaplanskaia, I B; Obukhova, T N; Kliasova, G A; Gorgidze, L A; Churakova, Zh V; Kremenetskaia, A M; Vorob'ev, A I

    2009-01-01

    Primary skin large B-cell lymphosarcomas (PLBCL) present with skin lesions, other organs and systems are not involved. As CHOP courses are not high effective in PLBCL, we were the first to treat a patient with modified block therapy NHL BFM-90. A complete remission was achieved after the first course of polychemotherapy and was consolidated by two courses of treatment. Further follow-up is needed.

  3. Nano composite of CeO2 and High-Coercivity Magnetic Carrier with Large Specific Surface Area

    International Nuclear Information System (INIS)

    Mantlikova, A. R.; Pacakova, B.; Kubickova, S.; Vejpravova, J.; Plocek, J.; Vik, O.; Niznansky, D.; Slouf, M.

    2016-01-01

    We succeeded in the preparation of CoFe 2 O 4 /CeO 2 nano composites with very high specific surface area (up to 264 g/m 2 ). First, highly crystalline nanoparticles (NP s ) of CoFe 2 O 4 (4.7 nm) were prepared by hydrothermal method in water-alcohol-oleic acid system. The oleate surface coating was subsequently modified by ligand exchange to citrate. Then the NP s were embedded in CeO 2 using heterogeneous precipitation from diluted Ce 3 + sulphate solution. Dried samples were characterized by Powder X-Ray Diffraction, Energy Dispersive X-Ray Analysis, Scanning and Transmission Electron Microscopy, Moessbauer Spectroscopy, and Brunauer-Emmett-Teller method. Moreover, detailed investigation of magnetic properties of the bare NP s and final composite was carried out. We observed homogeneous embedding of the magnetic NP s into the CeO 2 without significant change of their size and magnetic properties. We have thus demonstrated that the proposed synthesis method is suitable for preparation of extremely fine CeO 2 nano powders and their nano composites with NP s . The morphology and magnetic nature of the obtained nano composites make them a promising candidate for magneto responsive catalysis.

  4. Nanocomposite of CeO2 and High-Coercivity Magnetic Carrier with Large Specific Surface Area

    Directory of Open Access Journals (Sweden)

    Alice Reznickova Mantlikova

    2016-01-01

    Full Text Available We succeeded in the preparation of CoFe2O4/CeO2 nanocomposites with very high specific surface area (up to 264 g/m2. First, highly crystalline nanoparticles (NPs of CoFe2O4 (4.7 nm were prepared by hydrothermal method in water-alcohol-oleic acid system. The oleate surface coating was subsequently modified by ligand exchange to citrate. Then the NPs were embedded in CeO2 using heterogeneous precipitation from diluted Ce3+ sulphate solution. Dried samples were characterized by Powder X-Ray Diffraction, Energy Dispersive X-Ray Analysis, Scanning and Transmission Electron Microscopy, Mössbauer Spectroscopy, and Brunauer-Emmett-Teller method. Moreover, detailed investigation of magnetic properties of the bare NPs and final composite was carried out. We observed homogeneous embedding of the magnetic NPs into the CeO2 without significant change of their size and magnetic properties. We have thus demonstrated that the proposed synthesis method is suitable for preparation of extremely fine CeO2 nanopowders and their nanocomposites with NPs. The morphology and magnetic nature of the obtained nanocomposites make them a promising candidate for magnetoresponsive catalysis.

  5. Evidence for Topological Edge States in a Large Energy Gap near the Step Edges on the Surface of ZrTe_{5}

    Directory of Open Access Journals (Sweden)

    R. Wu

    2016-05-01

    Full Text Available Two-dimensional topological insulators with a large bulk band gap are promising for experimental studies of quantum spin Hall effect and for spintronic device applications. Despite considerable theoretical efforts in predicting large-gap two-dimensional topological insulator candidates, none of them have been experimentally demonstrated to have a full gap, which is crucial for quantum spin Hall effect. Here, by combining scanning tunneling microscopy/spectroscopy and angle-resolved photoemission spectroscopy, we reveal that ZrTe_{5} crystal hosts a large full gap of ∼100  meV on the surface and a nearly constant density of states within the entire gap at the monolayer step edge. These features are well reproduced by our first-principles calculations, which point to the topologically nontrivial nature of the edge states.

  6. A large 3D physical model: a tool to investigate the consequences of ground movements on the surface structures

    Directory of Open Access Journals (Sweden)

    Hor B.

    2010-06-01

    Full Text Available Soil subsidence of various extend and amplitude can result from the failure of underground cavities, whether natural (for example caused by the dissolution of rocks by underground water flow or man-made (such as mines. The impact of the ground movements on existing structures (houses, buildings, bridges, etc… is generally dramatic. A large small-scale physical model is developed in order to improve our understanding of the behaviour of the building subjected to ground subsidence or the collapse of cavities. We focus on the soil-structure interaction and on the mitigation techniques allowing reducing the vulnerability of the buildings (structures.

  7. A facile and cost-effective approach to engineer surface roughness for preparation of large-scale superhydrophobic substrate with high adhesive force

    Science.gov (United States)

    Zhou, Bingpu; Tian, Jingxuan; Wang, Cong; Gao, Yibo; Wen, Weijia

    2016-12-01

    This study presents a convenient avenue to fabricate polydimethylsiloxane (PDMS) with controllable surface morphologies and wetting characteristics via standard molding technique. The templates with engineered surface roughness were simply prepared by combinations of microfluidics and photo-polymerization of N-Isopropylacrylamide (NIPAM). The surface morphology of mold could be adjusted via ultraviolet-curing duration or the grafting density, which means that the surface of PDMS sample replicated from the mold could also be easily controlled based on the proposed method. Furthermore, via multiple grafting and replication processes, we have successfully demonstrated that hydrophobicity properties of prepared PDMS samples could be swiftly enhanced to ∼154° with highly adhesive force with resident water droplets. The obtained PDMS samples exhibited well resistance to external mechanical deformation even up to 100 cycles. The proposed scheme is timesaving, cost-effective and suitable for large-scale production of superhydrophobic PDMS substrates. We believe that the presented approach can provide a promising method for preparing superhydrophobic surface with highly adhesive force for on-chip liquid transport, localized reaction, etc.

  8. Large-area single-crystal graphene grown on a recrystallized Cu(111) surface by using a hole-pocket method

    Science.gov (United States)

    Phan, Hoang Danh; Jung, Jaehyuck; Kim, Youngchan; Huynh, Van Ngoc; Lee, Changgu

    2016-07-01

    We describe an efficient chemical vapor deposition (CVD) method for synthesizing graphene with a single crystal orientation on the whole surface of a copper (Cu) foil. We specifically synthesized graphene on the inner surface of a folded Cu foil, on which small holes were made for regulating the permeation and adsorption of the gases used for the synthesis. We compared the results of this method, which we call a ``hole-pocket'' method, with previously developed methods involving traditional synthesis on an open Cu foil and a Cu ``pita-pocket''. From these comparisons, we found the orientation of recrystallized Cu to depend on the shape of the Cu foil. Our hole-pocket method did not require treatment of the Cu surface with a complicated process to reduce the density of nucleation seeds in order to synthesize large hexagonal graphene grains, nor did it require the use of a single-crystalline substrate because methane passing through holes on the upper side of the hole-pocket slowly decomposed into carbon atoms and the control of the evaporation of Cu inside the foil pocket helped induce a transformation of the Cu domains to Cu(111). The current hole-pocket method resulted in domains that were both large, ranging from 2-5 mm in size, and oriented in the same manner. By extending the synthesis time, we were able to obtain continuous large-area films of single-crystalline orientation on the whole surface with dimensions of several centimeters.We describe an efficient chemical vapor deposition (CVD) method for synthesizing graphene with a single crystal orientation on the whole surface of a copper (Cu) foil. We specifically synthesized graphene on the inner surface of a folded Cu foil, on which small holes were made for regulating the permeation and adsorption of the gases used for the synthesis. We compared the results of this method, which we call a ``hole-pocket'' method, with previously developed methods involving traditional synthesis on an open Cu foil and a Cu

  9. Entrance surface dose and image quality: Comparison of adult chest and abdominal X-ray examinations in general practitioner clinics, public and private hospitals in Malaysia

    International Nuclear Information System (INIS)

    Hambali, A. S.; Ng, K. H.; Abdullah, B. J. J.; Wang, H. B.; Jamal, N.; Spelic, D. C.; Suleiman, O. H.

    2009-01-01

    This study was undertaken to compare the entrance surface dose (ESD) and image quality of adult chest and abdominal X-ray examinations conducted at general practitioner (GP) clinics, and public and private hospitals in Malaysia. The surveyed facilities were randomly selected within a given category (28 GP clinics, 20 public hospitals and 15 private hospitals). Only departmental X-ray units were involved in the survey. Chest examinations were done at all facilities, while only hospitals performed abdominal examinations. This study used the x-ray attenuation phantoms and protocols developed for the Nationwide Evaluation of X-ray Trends (NEXT) survey program in the United States. The ESD was calculated from measurements of exposure and clinical geometry. An image quality test tool was used to evaluate the low-contrast detectability and high-contrast detail performance under typical clinical conditions. The median ESD value for the adult chest X-ray examination was the highest (0.25 mGy) at GP clinics, followed by private hospitals (0.22 mGy) and public hospitals (0.17 mGy). The median ESD for the adult abdominal X-ray examination at public hospitals (3.35 mGy) was higher than that for private hospitals (2.81 mGy). Results of image quality assessment for the chest X-ray examination show that all facility types have a similar median spatial resolution and low-contrast detectability. For the abdominal X-ray examination, public hospitals have a similar median spatial resolution but larger low-contrast detectability compared with private hospitals. The results of this survey clearly show that there is room for further improvement in performing chest and abdominal X-ray examinations in Malaysia. (authors)

  10. Large-scale FMO-MP3 calculations on the surface proteins of influenza virus, hemagglutinin (HA) and neuraminidase (NA)

    Science.gov (United States)

    Mochizuki, Yuji; Yamashita, Katsumi; Fukuzawa, Kaori; Takematsu, Kazutomo; Watanabe, Hirofumi; Taguchi, Naoki; Okiyama, Yoshio; Tsuboi, Misako; Nakano, Tatsuya; Tanaka, Shigenori

    2010-06-01

    Two proteins on the influenza virus surface have been well known. One is hemagglutinin (HA) associated with the infection to cells. The fragment molecular orbital (FMO) calculations were performed on a complex consisting of HA trimer and two Fab-fragments at the third-order Møller-Plesset perturbation (MP3) level. The numbers of residues and 6-31G basis functions were 2351 and 201276, and thus a massively parallel-vector computer was utilized to accelerate the processing. This FMO-MP3 job was completed in 5.8 h with 1024 processors. Another protein is neuraminidase (NA) involved in the escape from infected cells. The FMO-MP3 calculation was also applied to analyze the interactions between oseltamivir and surrounding residues in pharmacophore.

  11. Naturally occurring mutations in large surface genes related to occult infection of hepatitis B virus genotype C.

    Directory of Open Access Journals (Sweden)

    Hong Kim

    Full Text Available Molecular mechanisms related to occult hepatitis B virus (HBV infection, particularly those based on genotype C infection, have rarely been determined thus far in the ongoing efforts to determine infection mechanisms. Therefore, we aim to elucidate the mutation patterns in the surface open reading frame (S ORF underlying occult infections of HBV genotype C in the present study. Nested PCRs were applied to 624 HBV surface antigen (HBsAg negative Korean subjects. Cloning and sequencing of the S ORF gene was applied to 41 occult cases and 40 control chronic carriers. Forty-one (6.6% of the 624 Korean adults with HBsAg-negative serostatus were found to be positive for DNA according to nested PCR tests. Mutation frequencies in the three regions labeled here as preS1, preS2, and S were significantly higher in the occult subjects compared to the carriers in all cases. A total of two types of deletions, preS1 deletions in the start codon and preS2 deletions as well as nine types of point mutations were significantly implicated in the occult infection cases. Mutations within the "a" determinant region in HBsAg were found more frequently in the occult subjects than in the carriers. Mutations leading to premature termination of S ORF were found in 16 occult subjects (39.0% but only in one subject from among the carriers (2.5%. In conclusion, our data suggest that preS deletions, the premature termination of S ORF, and "a" determinant mutations are associated with occult infections of HBV genotype C among a HBsAg-negative population. The novel mutation patterns related to occult infection introduced in the present study can help to broaden our understanding of HBV occult infections.

  12. Pollution, toxicity, and ecological risk of heavy metals in surface river sediments of a large basin undergoing rapid economic development.

    Science.gov (United States)

    Tang, Wenzhong; Zhang, Chao; Zhao, Yu; Shan, Baoqing; Song, Zhixin

    2017-05-01

    A comprehensive and detailed investigation of heavy metal pollution, toxicity, and ecological risk assessment was conducted for the surface river sediments of the Haihe Basin in China based on 220 sampling sites selected in 2013. The average concentrations of Cr, Cu, Ni, Pb, and Zn in the sediments were 129 mg/kg, 63.4 mg/kg, 36.6 mg/kg, 50.0 mg/kg, and 202 mg/kg, respectively. As indicated by the geoaccumulation and pollution load indices, most surface river sediments of the Haihe Basin were contaminated with the investigated metals, especially in the junction region of the Zi Ya He and Hei Long Gang watersheds. The 5 heavy metals in the sediments all had anthropogenic sources, and the enrichment degrees followed the order Cu > Pb > Zn > Cr > Ni, with mean enrichment factors of 3.27, 2.77, 2.58, 1.81, and 1.44, respectively. According to the mean index of comprehensive potential ecological risk (38.9), the studied sediments of the Haihe Basin showed low potential ecological risk, but the sediments were potentially biologically toxic based on the mean probable effect concentration quotient (0.547), which may be the result of speciation of the 5 metals in the sediments. The results indicate that heavy metal pollution should be considered during the development of ecological restoration strategies in the Haihe Basin. Environ Toxicol Chem 2017;36:1149-1155. © 2016 SETAC. © 2016 SETAC.

  13. Spatially resolving the atmospheric dynamics over the surface of red supergiants with the Very Large Telescope Interferometer

    Science.gov (United States)

    Ohnaka, K.

    2013-05-01

    The mass-loss mechanism in red supergiants is a long-stand-ing problem. The milliarcsecond angular resolution achieved by infrared long-baseline interferometry provides us with the only way to spatially resolve the region where the material is accelerated. For this goal, the 2.3 μm CO lines are important, because they form in the upper photosphere and the outer atmosphere (so-called MOLsphere). We present high-spatial and high-spectral resolution observations of the 2.3 μm CO lines in the red supergiants Betelgeuse and Antares using the Very Large Telescope Interferometer (VLTI). This has enabled us to spatially resolve the gas dynamics in the photosphere (and the MOLsphere) for the first time other than the Sun. We have detected vigorous motions of large CO gas clumps with velocities of up to 20-30 km s-1. Comparison of the CO line data taken 1 year apart shows a significant change in the dynamics of the atmosphere. In contrast to the CO line data, the continuum data reveal no or only marginal time variations. The observationally estimated gas density in the outer atmosphere at 1.3-1.4 R⋆ is higher than the values predicted by the current 3-D convection simulations by 6 to 11 orders of magnitude. Therefore, at the moment, convection alone cannot explain the detected vigorous gas motions in the extended outer atmosphere of Betelgeuse and Antares.

  14. Spatial distribution of gamma radiation levels in surface soils from Jaduguda uranium mineralization zone, Jharkhand, India, using γ-ray spectrometry, and determination of outdoor dose to the population

    Directory of Open Access Journals (Sweden)

    Maharana Mandakini

    2010-01-01

    Full Text Available The concentrations of natural radionuclides in surface soil samples around selected villages of Jaduguda were investigated and compared with the radioactivity level in the region. Concentrations of 238 U, 232 Th, and 40 K were determined by a gamma ray spectrometer using the HPGe detector with 50% relative efficiency, and the radiation dose to the local population was estimated. The average estimated activity concentrations of 238 U, 232 Th, and 40 K in the surface soil were 53.8, 44.2 and 464.2 Bq kg -1 respectively. The average absorbed dose rate in the study area was estimated to be 72.5 nGy h-1, where as the annual effective dose to the population was 0.09 mSv y-1. A correlation analysis was made between measured dose rate and individual radionuclides, in order to delineate the contribution of the respective nuclides towards dose rate. The radio-elemental concentrations of uranium, thorium and potassium estimated for the soils, in the study area, indicated the enrichment of uranium series nuclide. The results of the present study were subsequently compared with international and national recommended values.

  15. Peanut Shell-Derived Carbon Solid Acid with Large Surface Area and Its Application for the Catalytic Hydrolysis of Cyclohexyl Acetate

    Directory of Open Access Journals (Sweden)

    Wei Xue

    2016-10-01

    Full Text Available A carbon solid acid with large surface area (CSALA was prepared by partial carbonization of H3PO4 pre-treated peanut shells followed by sulfonation with concentrated H2SO4. The structure and acidity of CSALA were characterized by N2 adsorption–desorption, scanning electron microscopy (SEM, X-ray powder diffraction (XRD, 13C cross polarization (CP/magic angle spinning (MAS nuclear magnetic resonance (NMR, X-ray photoelectron spectroscopy (XPS, Fourier transform-infrared spectroscopy (FT-IR, titration, and elemental analysis. The results demonstrated that the CSALA was an amorphous carbon material with a surface area of 387.4 m2/g. SO3H groups formed on the surface with a density of 0.46 mmol/g, with 1.11 mmol/g of COOH and 0.39 mmol/g of phenolic OH. Densities of the latter two groups were notably greater than those observed on a carbon solid acid (CSA with a surface area of 10.1 m2/g. The CSALA catalyst showed better performance than the CSA for the hydrolysis of cyclohexyl acetate to cyclohexanol. Under optimal reaction conditions, cyclohexyl acetate conversion was 86.6% with 97.3% selectivity for cyclohexanol, while the results were 25.0% and 99.4%, respectively, catalyzed by CSA. The high activity of the CSALA could be attributed to its high density of COOH and large surface area. Moreover, the CSALA showed good reusability. Its catalytic activity decreased slightly during the first two cycles due to the leaching of polycyclic aromatic hydrocarbon-containing SO3H groups, and then remained constant during following uses.

  16. Implementation of Water Bolus in Patient with Large Tissue Defect

    International Nuclear Information System (INIS)

    Park, Hyo Kuk; Kim, Joo Ho; Lee, Sang Kyu; Yoon, Jong Won; Cho, Jeong Hee; Kim, Dong Wook

    2006-01-01

    To demonstrate that water bolus in the patient surface can decrease the dose inhomogeneity by patient surface large tissue defect when the surface is in an electron-beam field. And We tried to find a easy way to water control. To demonstrate the use of water bolus in the irregular surface clinically, the case of a patient with myxofibrosarcoma of the chest wall who was treated with electrons. We obtained dose distribution using missing tissue option of PINACLE 6.2b (ADAC, USA). We fabricate a Mev-green for water bolus in patient with defect of tissue. Then put the water bolus which is vinyl packed water into the designed Mev-green. We performed CT scan with CT-simulator. Three-dimensional (3D) dose distributions with and without water bolus in the large irregular chest wall were calculated for a representative patient. Resulting dose distributions and dose-volume histograms of water bolus were compared with missing tissue option and non bolus plans. We fabricate a new water control device. Controlled Water bolus markedly decrease the dose heterogeneity, and minimizes normal tissue exposure caused by the surface irregularities of the chest wall mass. In the test case, The non bolus plan has a maximum target dose of 132%. After applying water bolus, the maximum target dose has been reduced substantially to 110.4%. The maximum target dose was reduced by 21.6% using this technique. The results showed that controlled water bolus could significantly improve the dose homogeneity in the PTV for patients treated with electron therapy using water control device. This technique may reduce the incidence of normal organ complications that occur after electron-beam therapy in irregular surface. And our new device shows handiness of water control.

  17. Enjebi Island dose assessment

    International Nuclear Information System (INIS)

    Robison, W.L.; Conrado, C.L.; Phillips, W.A.

    1987-07-01

    We have updeated the radiological dose assessment for Enjebi Island at Enewetak Atoll using data derived from analysis of food crops grown on Enjebi. This is a much more precise assessment of potential doses to people resettling Enjebi Island than the 1980 assessment in which there were no data available from food crops on Enjebi. Details of the methods and data used to evaluate each exposure pathway are presented. The terrestrial food chain is the most significant potential exposure pathway and 137 Cs is the radionuclide responsible for most of the estimated dose over the next 50 y. The doses are calculated assuming a resettlement date of 1990. The average wholebody maximum annual estimated dose equivalent derived using our diet model is 166 mremy;the effective dose equivalent is 169 mremy. The estimated 30-, 50-, and 70-y integral whole-body dose equivalents are 3.5 rem, 5.1 rem, and 6.2 rem, respectively. Bone-marrow dose equivalents are only slightly higher than the whole-body estimates in each case. The bone-surface cells (endosteal cells) receive the highest dose, but they are a less sensitive cell population and are less sensitive to fatal cancer induction than whole body and bone marrow. The effective dose equivalents for 30, 50, and 70 y are 3.6 rem, 5.3 rem, and 6.6 rem, respectively. 79 refs., 17 figs., 24 tabs

  18. Differential Impact of Relative Dose-Intensity Reductions in Diffuse Large B-Cell Lymphoma Treated with R-CHOP21 or R-CHOP14.

    Directory of Open Access Journals (Sweden)

    Antonio Gutiérrez

    Full Text Available DLBCL is an aggressive lymphoma treated with R-CHOP. Recently, attempts have been made to improve the outcome by increasing both dose-density and intensity but there have been no benefits in terms of survival. When treating malignancies RDI is important to consider but there is little published information on DLBCL. The purpose of this study was to analyze the differential prognostic impact of RDI in two cohorts of DLBCL patients treated with R-CHOP21 or R-CHOP14. From January 2001 to August 2013 we included DLBCL patients homogenously treated with R-CHOP21 or R-CHOP14, with or without radiotherapy, at University Hospital Son Espases, Hospital Son Llatzer of Palma and Hospital del Mar of Barcelona (N = 157. In order to avoid selection bias the patients were retrospectively identified from the Pathology Department and Pharmacy registries. Median follow-up was 68 months. There was no difference in the response or survival between the two cohorts. In the R-CHOP21 group, both a reduction higher than 15% in RDI (RR 7.41 and R-IPI (RR 2.99 were independently associated with OS. However, a reduction higher than 15% in RDI (RR 4.41 was only noted for PFS. In the R-CHOP14 group, NCCN-IPI (RR 7.09 and B-symptoms (RR 5.37 for OS; AA stage III-IV (RR 6.26 and bulky disease (RR 4.05 for PFS. There was a trend towards a higher rate of RDI reduction observed in the R-CHOP14 group but it only made an impact in the R-CHOP21 group. We conclude that R-CHOP21 and R-CHOP14 are equivalent regimens in terms of response and survival, but only if RDI reductions are avoided. For patients receiving R-CHOP21 we recommend using clinical and support measures in order to avoid RDI reductions.

  19. Th1/2 Immune Response Signature Predicts Outcome after Dose-Dense Immunochemotherapy in Patients with High Risk Diffuse Large B-Cell Lymphoma – Results from Nordic Lymphoma Group Trials

    DEFF Research Database (Denmark)

    M, Autio; Jørgensen, Judit Meszaros; SK, Leivonen

    treatment-specific roles in diffuse large B-cell lymphoma. For the high risk DLBCL patients treated with dose-dense immunochemotherapy, high expression of type 1/2 immune response signature genes predicts a poor outcome. A detailed characterization of immune cell composition in the tumor microenvironment......Introduction: Despite better therapeutic options and improved survival of diffuse large B-cell lymphoma (DLBCL), 30-40% of the patients still relapse and have dismal prognosis. Recently, the impact of genomic aberrations, allowing lymphoma cells to escape immune recognition on DLBCL pathogenesis...... has been recognized. However, whether immune related signatures could be used as determinants for treatment outcome has not been rigorously evaluated. Here, our aim was to elucidate the immunologic characteristics of the tumor microenvironment, and associate the findings with outcome in patients...

  20. Large-scale, rapid synthesis and application in surface-enhanced Raman spectroscopy of sub-micrometer polyhedral gold nanocrystals

    International Nuclear Information System (INIS)

    Guo Shaojun; Wang Yuling; Wang Erkang

    2007-01-01

    Macromolecule-protected sub-micrometer polyhedral gold nanocrystals have been facilely prepared by heating an aqueous solution containing poly (N-vinyl-2-pyrrolidone) (PVP) and HAuCl 4 without adding other reducing agents. Scanning electron microscopy (SEM), energy-dispersive x-ray spectroscopy (EDX), ultraviolet-visible-near-infrared spectroscopy (UV-vis-NIR), and x-ray diffraction (XRD) were employed to characterize the obtained polyhedral gold nanocrystals. It is found that the 10:1 molar ratio of PVP to gold is a key factor for obtaining quasi-monodisperse polyhedral gold nanocrystals. Furthermore, the application of polyhedral gold nanocrystals in surface-enhanced Raman scattering (SERS) was investigated by using 4-aminothiophenol (4-ATP) as a probe molecule. The results indicated that the sub-micrometer polyhedral gold nanocrystals modified on the ITO substrate exhibited higher SERS activity compared to the traditional gold nanoparticle modified film. The enhancement factor (EF) on polyhedral gold nanocrystals was about six times larger than that obtained on aggregated gold nanoparticles (∼25 nm)

  1. High performance AlScN thin film based surface acoustic wave devices with large electromechanical coupling coefficient

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Wenbo; He, Xingli; Ye, Zhi, E-mail: yezhi@zju.edu.cn, E-mail: jl2@bolton.ac.uk; Wang, Xiaozhi [Department of Information Science and Electronic Engineering, Zhejiang University and Cyrus Tang Centre for Sensor Materials and Applications, 38 Zheda Road, Hangzhou 310027 (China); Mayrhofer, Patrick M.; Gillinger, Manuel; Bittner, Achim; Schmid, Ulrich [Institute of Sensor and Actuator Systems, Vienna University of Technology, Floragasse, 7/2/366-MST, A-1040 Vienna (Austria); Luo, J. K., E-mail: yezhi@zju.edu.cn, E-mail: jl2@bolton.ac.uk [Institute of Renewable Energy Environmental Technology, University of Bolton, Deane Road, Bolton BL3 5AB (United Kingdom); Department of Information Science and Electronic Engineering, Zhejiang University and Cyrus Tang Centre for Sensor Materials and Applications, 38 Zheda Road, Hangzhou 310027 (China)

    2014-09-29

    AlN and AlScN thin films with 27% scandium (Sc) were synthesized by DC magnetron sputtering deposition and used to fabricate surface acoustic wave (SAW) devices. Compared with AlN-based devices, the AlScN SAW devices exhibit much better transmission properties. Scandium doping results in electromechanical coupling coefficient, K{sup 2}, in the range of 2.0% ∼ 2.2% for a wide normalized thickness range, more than a 300% increase compared to that of AlN-based SAW devices, thus demonstrating the potential applications of AlScN in high frequency resonators, sensors, and high efficiency energy harvesting devices. The coupling coefficients of the present AlScN based SAW devices are much higher than that of the theoretical calculation based on some assumptions for AlScN piezoelectric material properties, implying there is a need for in-depth investigations on the material properties of AlScN.

  2. A measurement strategy and an error-compensation model for the on-machine laser measurement of large-scale free-form surfaces

    International Nuclear Information System (INIS)

    Li, Bin; Li, Feng; Liu, Hongqi; Cai, Hui; Mao, Xinyong; Peng, Fangyu

    2014-01-01

    This study presents a novel measurement strategy and an error-compensation model for the measurement of large-scale free-form surfaces in on-machine laser measurement systems. To improve the measurement accuracy, the effects of the scan depth, surface roughness, incident angle and azimuth angle on the measurement results were investigated experimentally, and a practical measurement strategy considering the position and orientation of the sensor is presented. Also, a semi-quantitative model based on geometrical optics is proposed to compensate for the measurement error associated with the incident angle. The normal vector of the measurement point is determined using a cross-curve method from the acquired surface data. Then, the azimuth angle and incident angle are calculated to inform the measurement strategy and error-compensation model, respectively. The measurement strategy and error-compensation model are verified through the measurement of a large propeller blade on a heavy machine tool in a factory environment. The results demonstrate that the strategy and the model are effective in increasing the measurement accuracy. (paper)

  3. The Large-scale Coronal Structure of the 2017 August 21 Great American Eclipse: An Assessment of Solar Surface Flux Transport Model Enabled Predictions and Observations

    Science.gov (United States)

    Nandy, Dibyendu; Bhowmik, Prantika; Yeates, Anthony R.; Panda, Suman; Tarafder, Rajashik; Dash, Soumyaranjan

    2018-01-01

    On 2017 August 21, a total solar eclipse swept across the contiguous United States, providing excellent opportunities for diagnostics of the Sun’s corona. The Sun’s coronal structure is notoriously difficult to observe except during solar eclipses; thus, theoretical models must be relied upon for inferring the underlying magnetic structure of the Sun’s outer atmosphere. These models are necessary for understanding the role of magnetic fields in the heating of the corona to a million degrees and the generation of severe space weather. Here we present a methodology for predicting the structure of the coronal field based on model forward runs of a solar surface flux transport model, whose predicted surface field is utilized to extrapolate future coronal magnetic field structures. This prescription was applied to the 2017 August 21 solar eclipse. A post-eclipse analysis shows good agreement between model simulated and observed coronal structures and their locations on the limb. We demonstrate that slow changes in the Sun’s surface magnetic field distribution driven by long-term flux emergence and its evolution governs large-scale coronal structures with a (plausibly cycle-phase dependent) dynamical memory timescale on the order of a few solar rotations, opening up the possibility for large-scale, global corona predictions at least a month in advance.

  4. Dose on the entrance surface of thyroid, crystalline lens and gonads during the chest X-rays studies; Dosis en la superficie de entrada de tiroides, cristalino y gonadas durante los examenes radiologicos de torax

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez G, R.; Guerra M, J. A.; Pinedo S, A.; Hernandez O, M.; Duran M, H. A.; Salas L, M. A.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98000 Zacatecas (Mexico); Rivera M, T. [Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, IPN, Av. Legaria No. 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico); Azorin N, J. [Universidad Autonoma Metropolita, Unidad Iztapalapa, Av. San Rafael Atlixco 186, 09340 Mexico D. F. (Mexico)], e-mail: rgg_df@hotmail.com

    2009-10-15

    There were a measurement series in General Hospital of Fresnillo in X-rays department in areas of X-1 and X-2 ray rooms and in a neonatal intensive care unit 2, the dose was determined on the entrance surface into eyes, thyroid and gonads for patients undergoing to X-rays study of tele chest by thermoluminescent dosimetry. 5 dosemeters were used in each of the scans, found the following dose ranges 20+{sub -} 23 {mu}Gy to 350 +{sub -} 41 {mu}Gy. With results we can conclude that the used procedures and the calibration equipment are adequate. (Author)

  5. A method for the production of large volumes of WAF and CEWAF for dosing mesocosms to understand marine oil snow formation.

    Science.gov (United States)

    Wade, Terry L; Morales-McDevitt, Maya; Bera, Gopal; Shi, Dawai; Sweet, Stephen; Wang, Binbin; Gold-Bouchot, Gerado; Quigg, Antonietta; Knap, Anthony H

    2017-10-01

    Marine oil snow (MOS) formation is a mechanism to transport oil from the ocean surface to sediments. We describe here the use of 110L mesocosms designed to mimic oceanic parameters during an oil spill including the use of chemical dispersants in order to understand the processes controlling MOS formation. These experiments were not designed to be toxicity tests but rather to illustrate mechanisms. This paper focuses on the development of protocols needed to conduct experiments under environmentally relevant conditions to examine marine snow and MOS. The experiments required the production of over 500 liters of water accommodated fraction (WAF), chemically enhanced water accommodated fraction of oil (CEWAF) as well as diluted CEWAF (DCEWAF). A redesigned baffled (170 L) recirculating tank (BRT) system was used. Two mesocosm experiments (M1 and M2) were run for several days each. In both M1 and M2, marine snow and MOS was formed in controls and all treatments respectively. Estimated oil equivalent (EOE) concentrations of CEWAF were in the high range of concentrations reported during spills and field tests, while WAF and DCEWAF concentrations were within the range of concentrations reported during oil spills. EOE decreased rapidly within days in agreement with historic data and experiments.

  6. Constructing 2D BiOCl/C3N4 layered composite with large contact surface for visible-light-driven photocatalytic degradation

    Science.gov (United States)

    Liu, Wenwen; Qiao, Lulu; Zhu, Anquan; Liu, Yi; Pan, Jun

    2017-12-01

    The design and construction of a two-dimensional (2D) layered composite with large contact surface provide an efficient way for solving detrimental photoinduced carriers recombination. In this work, 2D layered composite coupling (001) facet of BiOCl nanoplates and (002) facet of C3N4 nanosheets was reasonable designed and successful constructed. In comparison with pure C3N4, the BiOCl/C3N4 hybrid structure with loading of 70% BiOCl exhibits the highest methyl orange photodegradation performance although BiOCl/C3N4 hybrid photocatalyst harvest less visible light. Obviously, enhanced photocatalytic performance is mainly ascribed to large contact surface of 2D layered hybrid structure, which is favorable for the interface electrons transfer and the separation of carriers between C3N4 and BiOCl. A probable degradation mechanism based on trapping experiments of active species, transient photocurrents, photoluminescence spectra, electrochemical impedance spectroscopy and energy band structures is proposed. This work may provide a further insight into the rational construction composites with large interface contact for high-efficiency light utilization.

  7. Long-Term Remission of Primary Bone Marrow Diffuse Large B-Cell Lymphoma Treated with High-Dose Chemotherapy Rescued by In Vivo Rituximab-Purged Autologous Stem Cells

    Directory of Open Access Journals (Sweden)

    Hiroshi Kazama

    2012-01-01

    Full Text Available Primary bone marrow diffuse large B-cell lymphoma (DLBCL is a rare type of extranodal lymphoma with poor prognosis. Here, we report a case of primary bone marrow DLBCL successfully treated with high-dose chemotherapy and rescued by in vivo rituximab-purged autologous stem cells. A 39-year-old woman visited our hospital because of anemia. Bone marrow examination revealed a large B-cell lymphoma invasion. An 18F-fluorodeoxyglucose positron emission tomography scan revealed disseminated bone marrow uptake without evidence of dissemination at other sites. These findings led to a diagnosis of primary bone marrow DLBCL. Our patient underwent R-CHOP (rituximab, cyclophosphamide, doxorubicin, vincristine, and prednisolone chemotherapy and achieved complete remission. Subsequently, she received high-dose chemotherapy with an in vivo rituximab-purged autologous stem cell transplant. Seven years have passed since the transplantation, and she remains in remission. This suggests that transplantation of an in vivo rituximab-purged autograft is a promising strategy for primary bone marrow DLBCL.

  8. Large-Scale Controls of the Surface Water Balance Over Land: Insights From a Systematic Review and Meta-Analysis

    Science.gov (United States)

    Padrón, Ryan S.; Gudmundsson, Lukas; Greve, Peter; Seneviratne, Sonia I.

    2017-11-01

    The long-term surface water balance over land is described by the partitioning of precipitation (P) into runoff and evapotranspiration (ET), and is commonly characterized by the ratio ET/P. The ratio between potential evapotranspiration (PET) and P is explicitly considered to be the primary control of ET/P within the Budyko framework, whereas all other controls are often integrated into a single parameter, ω. Although the joint effect of these additional controlling factors of ET/P can be significant, a detailed understanding of them is yet to be achieved. This study therefore introduces a new global data set for the long-term mean partitioning of P into ET and runoff in 2,733 catchments, which is based on in situ observations and assembled from a systematic examination of peer-reviewed studies. A total of 26 controls of ET/P that are proposed in the literature are assessed using the new data set. Results reveal that: (i) factors controlling ET/P vary between regions with different climate types; (ii) controls other than PET/P explain at least 35% of the ET/P variance in all regions, and up to ˜90% in arid climates; (iii) among these, climate factors and catchment slope dominate over other landscape characteristics; and (iv) despite the high attention that vegetation-related indices receive as controls of ET/P, they are found to play a minor and often nonsignificant role. Overall, this study provides a comprehensive picture on factors controlling the partitioning of P, with valuable insights for model development, watershed management, and the assessment of water resources around the globe.

  9. Ultra-Durable and Transparent Self-Cleaning Surfaces by Large-Scale Self-Assembly of Hierarchical Interpenetrated Polymer Networks.

    Science.gov (United States)

    Wong, William S Y; Stachurski, Zbigniew H; Nisbet, David R; Tricoli, Antonio

    2016-06-01

    In nature, durable self-cleaning surfaces such as the Lotus leaf rely on the multiscale architecture and cohesive regenerative properties of organic tissue. Real-world impact of synthetic replicas has been limited by the poor mechanical and chemical stability of the ultrafine hierarchical textures required for attaining a highly dewetting superhydrophobic state. Here, we present the low-cost synthesis of large-scale ultradurable superhydrophobic coatings by rapid template-free micronano texturing of interpenetrated polymer networks (IPNs). A highly transparent texture of soft yielding marshmallow-like pillars with an ultralow surface energy is obtained by sequential spraying of a novel polyurethane-acrylic colloidal suspension and a superhydrophobic nanoparticle solution. The resulting coatings demonstrate outstanding antiabrasion resistance, maintaining superhydrophobic water contact angles and a pristine lotus effect with sliding angles of below 10° for up to 120 continuous abrasion cycles. Furthermore, they also have excellent chemical- and photostability, preserving the initial performance upon more than 50 h exposure to intense UVC light (254 nm, 3.3 mW cm(-2)), 24 h of oil contamination, and highly acidic conditions (1 M HCl). This sprayable polyurethane-acrylic colloidal suspension and surface texture provide a rapid and low-cost approach for the substrate-independent fabrication of ultradurable transparent self-cleaning surfaces with superior abrasion, chemical, and UV-resistance.

  10. Development of new maskless manufacturing method for anti-reflection structure and application to large-area lens with curved surface

    Science.gov (United States)

    Yamamoto, Kazuya; Takaoka, Toshimitsu; Fukui, Hidetoshi; Haruta, Yasuyuki; Yamashita, Tomoya; Kitagawa, Seiichiro

    2016-03-01

    In general, thin-film coating process is widely applied on optical lens surface as anti-reflection function. In normal production process, at first lens is manufactured by molding, then anti-reflection is added by thin-film coating. In recent years, instead of thin-film coating, sub-wavelength structures adding on surface of molding die are widely studied and development to keep anti-reflection performance. As merits, applying sub-wavelength structure, coating process becomes unnecessary and it is possible to reduce man-hour costs. In addition to cost merit, these are some technical advantages on this study. Adhesion of coating depends on material of plastic, and it is impossible to apply anti-reflection function on arbitrary surface. Sub-wavelength structure can solve both problems. Manufacturing method of anti-reflection structure can be divided into two types mainly. One method is with the resist patterning, and the other is mask-less method that does not require patterning. What we have developed is new mask-less method which is no need for resist patterning and possible to impart an anti-reflection structure to large area and curved lens surface, and can be expected to apply to various market segments. We report developed technique and characteristics of production lens.

  11. In various protein complexes, disordered protomers have large per-residue surface areas and area of protein-, DNA- and RNA-binding interfaces.

    Science.gov (United States)

    Wu, Zhonghua; Hu, Gang; Yang, Jianyi; Peng, Zhenling; Uversky, Vladimir N; Kurgan, Lukasz

    2015-09-14

    We provide first large scale analysis of the peculiarities of surface areas of 5658 dissimilar (below 50% sequence similarity) proteins with known 3D-structures that bind to proteins, DNA or RNAs. We show here that area of the protein surface is highly correlated with the protein length. The size of the interface surface is only modestly correlated with the protein size, except for RNA-binding proteins where larger proteins are characterized by larger interfaces. Disordered proteins with disordered interfaces are characterized by significantly larger per-residue areas of their surfaces and interfaces when compared to the structured proteins. These result are applicable for proteins involved in interaction with DNA, RNA, and proteins and suggest that disordered proteins and binding regions are less compact and more likely to assume extended shape. We demonstrate that disordered protein binding residues in the interfaces of disordered proteins drive the increase in the per residue area of these interfaces. Our results can be used to predict in silico whether a given protomer from the DNA, RNA or protein complex is likely to be disordered in its unbound form. Copyright © 2015 Federation of European Biochemical Societies. Published by Elsevier B.V. All rights reserved.

  12. In flight measurement of steady and unsteady blade surface pressure of a single rotation large scale advanced prop-fan installed on the PTA aircraft

    Science.gov (United States)

    Parzych, D.; Boyd, L.; Meissner, W.; Wyrostek, A.

    1991-01-01

    An experiment was performed by Hamilton Standard, Division of United Technologies Corporation, under contract by LeRC, to measure the blade surface pressure of a large scale, 8 blade model prop-fan in flight. The test bed was the Gulfstream 2 Prop-Fan Test Assessment (PTA) aircraft. The objective of the test was to measure the steady and periodic blade surface pressure resulting from three different Prop-Fan air inflow angles at various takeoff and cruise conditions. The inflow angles were obtained by varying the nacelle tilt angles, which ranged from -3 to +2 degrees. A range of power loadings, tip speeds, and altitudes were tested at each nacelle tilt angle over the flight Mach number range of 0.30 to 0.80. Unsteady blade pressure data tabulated as Fourier coefficients for the first 35 harmonics of shaft rotational frequency and the steady (non-varying) pressure component are presented.

  13. Literature and data review for the surface-water pathway: Columbia River and adjacent coastal areas. Hanford Environmental Dose Reconstruction Project

    Energy Technology Data Exchange (ETDEWEB)

    Walters, W.H.; Dirkes, R.L.; Napier, B.A.

    1992-04-01

    As part of the Hanford Environmental Dose Reconstruction Project, Pacific Northwest Laboratory reviewed literature and data on radionuclide concentrations and distribution in the water, sediment, and biota of the Columbia River and adjacent coastal areas. Over 600 documents were reviewed including Hanford reports, reports by offsite agencies, journal articles, and graduate theses. Certain radionuclide concentration data were used in preliminary estimates of individual dose for the 1964--1966 time period. This report summarizes the literature and database review and the results of the preliminary dose estimates.

  14. Literature and data review for the surface-water pathway: Columbia River and adjacent coastal areas. Hanford Environmental Dose Reconstruction Project

    Energy Technology Data Exchange (ETDEWEB)

    Walters, W.H.; Dirkes, R.L.; Napier, B.A.

    1992-11-01

    As part of the Hanford Environmental Dose Reconstruction (HEDR) Project, Battelle, Pacific Northwest Laboratories reviewed literature and data on radionuclide concentrations and distribution in the water, sediment, and biota of the Columbia River and adjacent coastal areas. Over 600 documents were reviewed including Hanford reports, reports by offsite agencies, journal articles, and graduate theses. Radionuclide concentration data were used in preliminary estimates of individual dose for the period 1964 through 1966. This report summarizes the literature and database reviews and the results of the preliminary dose estimates.

  15. Longitudinal pressure-driven flows between superhydrophobic grooved surfaces: Large effective slip in the narrow-channel limit

    Science.gov (United States)

    Schnitzer, Ory; Yariv, Ehud

    2017-07-01

    The gross amplification of the fluid velocity in pressure-driven flows due to the introduction of superhydrophobic walls is commonly quantified by an effective slip length. The canonical duct-flow geometry involves a periodic structure of longitudinal shear-free stripes at either one or both of the bounding walls, corresponding to flat-meniscus gas bubbles trapped within a periodic array of grooves. This grating configuration is characterized by two geometric parameters, namely the ratio κ of channel width to microstructure period and the areal fraction Δ of the shear-free stripes. For wide channels, κ ≫1 , this geometry is known to possess an approximate solution where the dimensionless slip length λ , normalized by the duct semiwidth, is small, indicating a weak superhydrophobic effect. We here address the other extreme of narrow channels, κ ≪1 , identifying large O (κ-2) values of λ for the symmetric configuration, where both bounding walls are superhydrophobic. This velocity enhancement is associated with an unconventional Poiseuille-like flow profile where the parabolic velocity variation takes place in a direction parallel (rather than perpendicular) to the boundaries. Use of matched asymptotic expansions and conformal-mapping techniques provides λ up to O (κ-1) , establishing the approximationλ ˜κ-2Δ/33 +κ-1Δ/2π ln4 +⋯, which is in excellent agreement with a semianalytic solution of the dual equations governing the respective coefficients of a Fourier-series representation of the fluid velocity. No similar singularity occurs in the corresponding asymmetric configuration, involving a single superhydrophobic wall; in that geometry, a Hele-Shaw approximation shows that λ =O (1 ) .

  16. The impact of changes in parameterizations of surface drag and vertical diffusion on the large-scale circulation in the Community Atmosphere Model (CAM5)

    Science.gov (United States)

    Lindvall, Jenny; Svensson, Gunilla; Caballero, Rodrigo

    2017-06-01

    Simulations with the Community Atmosphere Model version 5 (CAM5) are used to analyze the sensitivity of the large-scale circulation to changes in parameterizations of orographic surface drag and vertical diffusion. Many GCMs and NWP models use enhanced turbulent mixing in stable conditions to improve simulations, while CAM5 cuts off all turbulence at high stabilities and instead employs a strong orographic surface stress parameterization, known as turbulent mountain stress (TMS). TMS completely dominates the surface stress over land and reduces the near-surface wind speeds compared to simulations without TMS. It is found that TMS is generally beneficial for the large-scale circulation as it improves zonal wind speeds, Arctic sea level pressure and zonal anomalies of the 500-hPa stream function, compared to ERA-Interim. It also alleviates atmospheric blocking frequency biases in the Northern Hemisphere. Using a scheme that instead allows for a modest increase of turbulent diffusion at higher stabilities only in the planetary boundary layer (PBL) appears to in some aspects have a similar, although much smaller, beneficial effect as TMS. Enhanced mixing throughout the atmospheric column, however, degrades the CAM5 simulation. Evaluating the simulations in comparison with detailed measurements at two locations reveals that TMS is detrimental for the PBL at the flat grassland ARM Southern Great Plains site, giving too strong wind turning and too deep PBLs. At the Sodankylä forest site, the effect of TMS is smaller due to the larger local vegetation roughness. At both sites, all simulations substantially overestimate the boundary layer ageostrophic flow.

  17. Porous carbon with a large surface area and an ultrahigh carbon purity via templating carbonization coupling with KOH activation as excellent supercapacitor electrode materials

    International Nuclear Information System (INIS)

    Sun, Fei; Gao, Jihui; Liu, Xin; Pi, Xinxin; Yang, Yuqi; Wu, Shaohua

    2016-01-01

    Highlights: • Simple templating carbonization method was developed to obtain porous carbons. • Surface etching by KOH activation greatly boosts surface area and carbon purity. • The as-obtained porous carbon delivers a high capacitance of 275 F g −1 . • Symmetric supercapacitor can achieved high energy density and power density. - Abstract: Large surface area and good structural stability, for porous carbons, are two crucial requirements to enable the constructed supercapacitors with high capacitance and long cycling lifespan. Herein, we successfully prepare porous carbon with a large surface area (3175 m 2 g −1 ) and an ultrahigh carbon purity (carbon atom ratio of 98.25%) via templating carbonization coupling with KOH activation. As-synthesized MTC-KOH exhibits excellent performances as supercapacitor electrode materials in terms of high specific capacitance and ultrahigh cycling stability. In a three electrode system, MTC-KOH delivers a high capacitance of 275 F g −1 at 0.5 A g −1 and still 120 F g −1 at a high rate of 30 A g −1 . There is almost no capacitance decay even after 10,000 cycles, demonstrating outstanding cycling stability. In comparison, pre-activated MTC with a hierarchical pore structure shows a better rate capability than microporous MTC-KOH. Moreover, the constructed symmetric supercapacitor using MTC-KOH can achieve high energy densities of 8.68 Wh kg −1 and 4.03 Wh kg −1 with the corresponding power densities of 108 W kg −1 and 6.49 kW kg −1 , respectively. Our work provides a simple design strategy to prepare highly porous carbons with high carbon purity for supercapacitors application.

  18. A large-scale superhydrophobic surface-enhanced Raman scattering (SERS) platform fabricated via capillary force lithography and assembly of Ag nanocubes for ultratrace molecular sensing.

    Science.gov (United States)

    Tan, Joel Ming Rui; Ruan, Justina Jiexin; Lee, Hiang Kwee; Phang, In Yee; Ling, Xing Yi

    2014-12-28

    An analytical platform with an ultratrace detection limit in the atto-molar (aM) concentration range is vital for forensic, industrial and environmental sectors that handle scarce/highly toxic samples. Superhydrophobic surface-enhanced Raman scattering (SERS) platforms serve as ideal platforms to enhance detection sensitivity by reducing the random spreading of aqueous solution. However, the fabrication of superhydrophobic SERS platforms is generally limited due to the use of sophisticated and expensive protocols and/or suffers structural and signal inconsistency. Herein, we demonstrate a high-throughput fabrication of a stable and uniform superhydrophobic SERS platform for ultratrace molecular sensing. Large-area box-like micropatterns of the polymeric surface are first fabricated using capillary force lithography (CFL). Subsequently, plasmonic properties are incorporated into the patterned surfaces by decorating with Ag nanocubes using the Langmuir-Schaefer technique. To create a stable superhydrophobic SERS platform, an additional 25 nm Ag film is coated over the Ag nanocube-decorated patterned template followed by chemical functionalization with perfluorodecanethiol. Our resulting superhydrophobic SERS platform demonstrates excellent water-repellency with a static contact angle of 165° ± 9° and a consequent analyte concentration factor of 59-fold, as compared to its hydrophilic counterpart. By combining the analyte concentration effect of superhydrophobic surfaces with the intense electromagnetic "hot spots" of Ag nanocubes, our superhydrophobic SERS platform achieves an ultra-low detection limit of 10(-17) M (10 aM) for rhodamine 6G using just 4 μL of analyte solutions, corresponding to an analytical SERS enhancement factor of 10(13). Our fabrication protocol demonstrates a simple, cost- and time-effective approach for the large-scale fabrication of a superhydrophobic SERS platform for ultratrace molecular detection.

  19. The usefulness of metal markers for CTV-based dose prescription in high-dose-rate interstitial brachytherapy

    International Nuclear Information System (INIS)

    Yoshida, Ken; Mitomo, Masanori; Nose, Takayuki; Koizumi, Masahiko; Nishiyama, Kinji; Yoshida, Mineo

    2002-01-01

    We employ a clinical target volume (CTV)-based dose prescription for high-dose-rate (HDR) interstitial brachytherapy. However, it is not easy to define CTV and organs at risk (OAR) from X-ray film or CT scanning. To solve this problem, we have utilized metal markers since October 1999. Moreover, metal markers can help modify dose prescription. By regulating the doses to the metal markers, refining the dose prescription can easily be achieved. In this research, we investigated the usefulness of the metal markers. Between October 1999 and May 2001, 51 patients were implanted with metal markers at Osaka Medical Center for Cancer and Cardiovascular Diseases (OMCC), Osaka National Hospital (ONH) and Sanda City Hospital (SCH). Forty-nine patients (head and neck: 32; pelvis: 11; soft tissue: 3; breast: 3) using metal markers were analyzed. During operation, we implanted 179 metal markers (49 patients) to CTV and 151 markers (26 patients) to OAR. At treatment planning, CTV was reconstructed judging from the metal markers, applicator position and operation records. Generally, we prescribed the tumoricidal dose to an isodose surface that covers CTV. We also planned to limit the doses to OAR lower than certain levels. The maximum normal tissue doses were decided 80%, 150%, 100%, 50% and 200% of the prescribed doses for the rectum, the urethra, the mandible, the skin and the large vessel, respectively. The doses to the metal markers using CTV-based dose prescription were generated. These were compared with the doses theoretically calculated with the Paris system. Treatment results were also investigated. The doses to the 158 metal markers (42 patients) for CTV were higher than ''tumoricidal dose''. In 7 patients, as a result of compromised dose prescription, 9 markers were lower than the tumoricidal dose. The other 12 markers (7%) were excluded from dose evaluation because they were judged as miss-implanted. The doses to the 142 metal markers (24 patients) for OAR were lower

  20. Dedicated Tool for Irradiation and Electrical Measurement of Large Surface Samples on the Beamline of a 2.5 Mev Pelletron Electron Accelerator: Application to Solar Cells

    OpenAIRE

    Lefèvre Jérémie; Le Houedec Patrice; Losco Jérôme; Cavani Olivier; Boizot Bruno

    2017-01-01

    We designed a tool allowing irradiation of large samples over a surface of A5 size dimension by means of a 2.5 MeV Pelletron electron accelerator. in situ electrical measurements (I-V, conductivity, etc.) can also be performed, in the dark or under illumination, to study radiation effects in materials. Irradiations and electrical measurements are achievable over a temperature range from 100 K to 300 K. The setup was initially developed to test real-size triple junction solar cells at low t...

  1. Effect of surface modification of CeO2 buffer layers on Jc and defect microstructures of large-area YBCO thin films

    International Nuclear Information System (INIS)

    Develos-Bagarinao, K; Yamasaki, H; Nakagawa, Y

    2006-01-01

    High-quality CeO 2 buffer layers are requisite for the successful growth of YBCO thin films with excellent properties on sapphire substrates. In this study, we evaluated the effect of surface modification of the CeO 2 layers on the properties of the YBCO thin films prepared by large-area pulsed laser deposition (PLD), in particular the critical current density J c and defect microstructure. High-temperature annealing (1050 deg. C ) has been found to significantly smoothen the very rough and granular surfaces of the as-grown CeO 2 layers (surface roughness rms∼5-10 nm) to atomic flatness (rms∼0.5 nm). However, a rather unique characteristic of the CeO 2 layers deposited by large-area PLD is the development of pores when subjected to prolonged high-temperature annealing. For very short annealing periods (10-20 min), the surface morphology becomes atomically flat, along with the appearance of a high density of 'nanopores' that are ∼40-100 nm in diameter and ∼3-5 nm in depth. Extending the annealing period to 60 min or more results in the development of a surface subtended with enlarged pores ∼0.2-0.5 μm in diameter. Compared with the YBCO thin films deposited on as-grown CeO 2 , YBCO thin films on annealed CeO 2 exhibited better homogeneity of J c and better crystalline texture. Among the YBCO thin films deposited on annealed CeO 2 , higher self-field and in-field J c was obtained for YBCO thin films deposited on CeO 2 with smooth surfaces but interspersed with nanopores. Investigation of the defect microstructure via the etch pit method in conjunction with atomic force microscopy (AFM) of the YBCO thin films revealed a high density of linear defects in the form of screw and edge dislocations, which correlated well with a high density of nanopores on annealed CeO 2 . Transmission electron microscopy (TEM) further confirmed the presence of threading dislocations clearly emanating from the nanopore sites. Angular dependence of J c revealed enhanced flux

  2. Characterization of large surface area polymer monoliths and their utility for rapid, selective solid phase extraction for improved sample clean up.

    Science.gov (United States)

    Candish, Esme; Wirth, Hans-Jürgen; Gooley, Andrew A; Shellie, Robert A; Hilder, Emily F

    2015-09-04

    While polymer monoliths are widely described for solid phase extraction (SPE), appropriate characterization is rarely provided to unravel the links between physical characteristics and observed advantages and disadvantages. Two known approaches to fabricate large surface area polymer monoliths with a bimodal pore structure were investigated. The first incorporated a high percentage of divinyl benzene (PDVB) and the second explored hypercrosslinking of pre-formed monoliths. Adsorption of probe analytes; anisole, benzoic acid, cinnamic acid, ibuprofen and cortisone were investigated using frontal analysis and the SPE performance was compared with particulate adsorbents. Frontal analysis of anisole described maximum adsorption capacities of 164mgg(-1) and 298mgg(-1) for hypercrosslinked and PDVB adsorbents, respectively. The solvated state specific surface area was calculated to be 341 and 518m(2)g(-1) respectively. BET revealed a hypercrosslinked surface area of 817m(2)g(-1), 2.5 times greater than in the solvated state. The PDVB BET surface area was 531m(2)g(-1), similar to the solvated state. Micropores of 1nm provided the enhanced surface area for hypercrosslinked adsorbents. PDVB displayed a pore size distribution of 1-6nm. Frontal analysis demonstrated the micropores present size exclusion for the larger probes. Recovery of anisole was determined by SPE using 0.4 and 1.0mLmin(-1). Recovery for PDVB remained constant at 90%±0.103 regardless of the extraction flow rate suggesting extraction performance is independent of flow rate. A more efficient sample purification of saccharin in urine was yielded by PDVB due to selective permeation of the small pores. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Multicentre evaluation of a novel vaginal dose reporting method in 153 cervical cancer patients

    DEFF Research Database (Denmark)

    Westerveld, Henrike; de Leeuw, Astrid; Kirchheiner, Kathrin

    2016-01-01

    Background and purpose Recently, a vaginal dose reporting method for combined EBRT and BT in cervical cancer patients was proposed. The current study was to evaluate vaginal doses with this method in a multicentre setting, wherein different applicators, dose rates and protocols were used. Material...... and methods In a subset of patients from the EMBRACE study, vaginal doses were evaluated. Doses at the applicator surface left/right and anterior/posterior and at 5 mm depth were measured. In addition, the dose at the Posterior–Inferior Border of Symphysis (PIBS) vaginal dose point and PIBS±2 cm......, corresponding to the mid and lower vagina, was measured. Results 153 patients from seven institutions were included. Large dose variations expressed in EQD2 with α/β = 3 Gy were seen between patients, in particular at the top left and right vaginal wall (median 195 (range 61–947) Gy/178 (61–980) Gy...

  4. Hypercrosslinked large surface area porous polymer monoliths for hydrophilic interaction liquid chromatography of small molecules featuring zwitterionic functionalities attached to gold nanoparticles held in layered structure.

    Science.gov (United States)

    Lv, Yongqin; Lin, Zhixing; Svec, Frantisek

    2012-10-16

    A novel approach to porous polymer monoliths hypercrosslinked to obtain large surface areas and modified with zwitterionic functionalities through the attachment of gold nanoparticles in a layered architecture has been developed. The capillary columns were used for the separation of small molecules in hydrophilic interaction liquid chromatography mode. First, a monolith with a very large surface area of 430 m(2)/g was prepared by hypercrosslinking from a generic poly(4-methylstyrene-co-vinylbenzyl chloride-co-divinylbenzene) monolith via a Friedel-Crafts reaction catalyzed with iron chloride. Free radical bromination then provided this hypercrosslinked monolith with 5.7 at % Br that further reacted with cystamine under microwave irradiation, resulting in a product containing 3.8 at % sulfur. Clipping the disulfide bonds with tris(2-carboxylethyl) phosphine liberated the desired thiol groups that bind the first layer of gold nanoparticles. These immobilized nanoparticles were an intermediate ligand enabling the attachment of polyethyleneimine as a spacer followed by immobilization of the second layer of gold nanoparticles which were eventually functionalized with zwitterionic cysteine. This layered architecture, prepared using 10 nm nanoparticles, contains 17.2 wt % Au, more than twice than that found in the first layer alone. Chromatographic performance of these hydrophilic monolithic columns was demonstrated with the separation of mixtures of nucleosides and peptides in hydrophilic interaction chromatography (HILIC) mode. A column efficiency of 51,000 plates/m was achieved for retained analyte cytosine.

  5. Building and calibrating a large-extent and high resolution coupled groundwater-land surface model using globally available data-sets

    Science.gov (United States)

    Sutanudjaja, E. H.; Van Beek, L. P.; de Jong, S. M.; van Geer, F.; Bierkens, M. F.

    2012-12-01

    The current generation of large-scale hydrological models generally lacks a groundwater model component simulating lateral groundwater flow. Large-scale groundwater models are rare due to a lack of hydro-geological data required for their parameterization and a lack of groundwater head data required for their calibration. In this study, we propose an approach to develop a large-extent fully-coupled land surface-groundwater model by using globally available datasets and calibrate it using a combination of discharge observations and remotely-sensed soil moisture data. The underlying objective is to devise a collection of methods that enables one to build and parameterize large-scale groundwater models in data-poor regions. The model used, PCR-GLOBWB-MOD, has a spatial resolution of 1 km x 1 km and operates on a daily basis. It consists of a single-layer MODFLOW groundwater model that is dynamically coupled to the PCR-GLOBWB land surface model. This fully-coupled model accommodates two-way interactions between surface water levels and groundwater head dynamics, as well as between upper soil moisture states and groundwater levels, including a capillary rise mechanism to sustain upper soil storage and thus to fulfill high evaporation demands (during dry conditions). As a test bed, we used the Rhine-Meuse basin, where more than 4000 groundwater head time series have been collected for validation purposes. The model was parameterized using globally available data-sets on surface elevation, drainage direction, land-cover, soil and lithology. Next, the model was calibrated using a brute force approach and massive parallel computing, i.e. by running the coupled groundwater-land surface model for more than 3000 different parameter sets. Here, we varied minimal soil moisture storage and saturated conductivities of the soil layers as well as aquifer transmissivities. Using different regularization strategies and calibration criteria we compared three calibration scenarios

  6. Simultaneous effects of surface spins: rarely large coercivity, high remanence magnetization and jumps in the hysteresis loops observed in CoFe2O4 nanoparticles.

    Science.gov (United States)

    Xu, S T; Ma, Y Q; Zheng, G H; Dai, Z X

    2015-04-21

    Well-dispersed uniform cobalt ferrite nanoparticles were synthesized by thermal decomposition of a metal-organic salt in organic solvent with a high boiling point. Some of the nanoparticles were diluted in a SiO2 matrix and then the undiluted and diluted samples were characterized and their magnetic behavior explored. The undiluted and diluted samples exhibited maximum coercivity Hc of 23,817 and 15,056 Oe at 10 K, respectively, which are the highest values reported to date, and the corresponding ratios of remanence (Mr) to saturation (Ms) magnetization (Mr/Ms) were as high as 0.85 and 0.76, respectively. Interestingly, the magnetic properties of the samples changed at 200 K, which was observed in magnetic hysteresis M(H) loops and zero-field cooling curves as well as the temperature dependence of Hc, Mr/Ms, anisotropy, dipolar field, and the magnetic grain size. Below 200 K, both samples have large effective anisotropy, which arises from the surface spins, resulting in large Hc and Mr/Ms. Above 200 K, the effective anisotropy decreases because there is no contribution from surface spins, while the dipolar interaction increases, resulting in small Hc and Mr/Ms. Our results indicate that strong anisotropy and weak dipolar interaction tend to increase Hc and Mr/Ms, and also clarify that the jumps around H = 0 in M(H) loops can be attributed to the reorientation of surface spins. This work exposes the underlying mechanism in nanoscale magnetic systems, which should lead to improved magnetic performance.

  7. Number of daily pills, dosing schedule, self-reported adherence and health status in 2010: a large cross-sectional study of HIV-infected patients on antiretroviral therapy.

    Science.gov (United States)

    Gianotti, N; Galli, L; Bocchiola, B; Cahua, T; Panzini, P; Zandonà, D; Salpietro, S; Maillard, M; Danise, A; Pazzi, A; Lazzarin, A; Castagna, A

    2013-03-01

    The aim of the study was to assess whether pill burden is associated with self-reported adherence to current combination antiretroviral regimens and health status in a large sample of unselected and chronically treated HIV-infected patients. An adherence and health status questionnaire was offered to all patients collecting their drugs between March and May 2010 at our clinic; both parameters were primarily evaluated using a visual analogue scale. Linear correlations were evaluated using Spearman's correlation coefficient. Wilcoxon's rank-sum test and the χ(2) test were used to compare quantitative and qualitative variables. The generalized linear model was used in multivariable analyses. Among 2763 subjects on treatment during the study period, 2114 (78.8% male; mean age 46.9 ± 8.84 years) were tested for adherence; 1803 (85.3%) had viral loads pill burden and dosing interval, adherence was higher in patients with undetectable HIV RNA (P pill burden (P = 0.019). In this highly adherent population, the number of daily pills was related to self-reported health status but not to self-reported adherence, whereas the dos