  1. Radiographic film: surface dose extrapolation techniques

    International Nuclear Information System (INIS)

    Cheung, T.; Yu, P.K.N.; Butson, M.J.; Cancer Services, Wollongong, NSW; Currie, M.

    2004-01-01

    Full text: Assessment of surface dose delivered from radiotherapy x-ray beams for optimal results should be performed both inside and outside the prescribed treatment fields An extrapolation technique can be used with radiographic film to perform surface dose assessment for open field high energy x-ray beams. This can produce an accurate 2 dimensional map of surface dose if required. Results have shown that surface % dose can be estimated within ±3% of parallel plate ionisation chamber results with radiographic film using a series of film layers to produce an extrapolated result. Extrapolated percentage dose assessment for 10cm, 20cmand 30cm square fields was estimated to be 15% ± 2%, 29% ± 3% and 38% ± 3% at the central axis and relatively uniform across the treatment field. Corresponding parallel plate ionisation chamber measurement are 16%, 27% and 37% respectively. Surface doses are also measured outside the treatment field which are mainly due to scattered electron contamination. To achieve this result, film calibration curves must be irradiated to similar x-ray field sizes as the experimental film to minimize quantitative variations in film optical density caused by varying x-ray spectrum with field size. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  2. Surface dose extrapolation measurements with radiographic film

    International Nuclear Information System (INIS)

    Butson, Martin J; Cheung Tsang; Yu, Peter K N; Currie, Michael

    2004-01-01

    Assessment of surface dose delivered from radiotherapy x-ray beams for optimal results should be performed both inside and outside the prescribed treatment fields. An extrapolation technique can be used with radiographic film to perform surface dose assessment for open field high energy x-ray beams. This can produce an accurate two-dimensional map of surface dose if required. Results have shown that the surface percentage dose can be estimated within ±3% of parallel plate ionization chamber results with radiographic film using a series of film layers to produce an extrapolated result. Extrapolated percentage dose assessment for 10 cm, 20 cm and 30 cm square fields was estimated to be 15% ± 2%, 29% ± 3% and 38% ± 3% at the central axis and relatively uniform across the treatment field. The corresponding parallel plate ionization chamber measurements are 16%, 27% and 37%, respectively. Surface doses are also measured outside the treatment field which are mainly due to scattered electron contamination. To achieve this result, film calibration curves must be irradiated to similar x-ray field sizes as the experimental film to minimize quantitative variations in film optical density caused by varying x-ray spectrum with field size. (note)

  3. Review of surface dose detectors in radiotherapy

    LENUS (Irish Health Repository)

    O'Shea, E.

    2006-11-20

    Several instruments have been used to measure absorbed radiation dose under non-electronic equilibrium conditions, such as in the build-up region or near the interface between two different media, including the surface. Many of these detectors are discussed in this paper. A common method of measuring the absorbed dose distribution and electron contamination in the build-up region of high-energy beams for radiation therapy is by means of parallel-plate ionisation chambers. Thermoluminescent dosimeters (TLDs), diodes and radiographic film have also been used to obtain surface dose measurements. The diamond detector was used recently by the author in an investigation on the effects of beam-modifying devices on skin dose and it is also described in this report

  4. Patient surface doses in computerized tomography examinations

    International Nuclear Information System (INIS)

    Vekic, B.; Kovacevic, S.; Ranogajec Komor, M.; Duvnjak, N.; Marusic, P.; Anic, P.; Dolencic, P.

    1996-01-01

    Computed tomography (CT) has become a major source of the population exposure to diagnostic x-rays, and acknowledge of the doses delivered by the CT equipment has become very important. Considerable efforts should be made to keep these doses to a reasonable minimum, without sacrificing the image quality. The conditions of exposure in CT are quite different from dose in conventional x-ray imaging. This has required the development of specific techniques for assessing patient dose from CT. The aims of this work were to determine the dose delivered to various organs of patients undergoing computed tomography of abdomen, thorax, pelvis and kidney as measured on the surface of the body and to estimate the risk to the patients. Dosimetric measurements were performed at two different CT scanners (Siemens SOMATOM DR-H ver. HC-1 and Shimadzu SCT-4500TE). The dose absorbed by different organs (gonads, chest, thyroid and eye lens) and by the examined part of the body of 95 patients of various sex and age were measured with TLD-700. The doses absorbed by different organs during the diagnostic CT examination of the body depend on the technical parameters, such as the number of scan, mAs, the thickness of scans, scanning times, tube voltage and other characteristics, some of each depend on the type and severity of illness. Clinical parameters, such as patient size and composition, and patient cooperation with regard to the control and motion, also influence the dose and the image quality. The highest dose measured in this study (89.19 mGy) was delivered to kidney during CT examination of this organ. (author)

  5. Patient surface doses in computerized tomography examinations

    International Nuclear Information System (INIS)

    Vekic, B; Kovacevic, S.; Ranogajec-Komor, M.; Duvnjak, N.; Marusic, P.; Anic, P.; Dolencic, P.

    1996-01-01

    The diagnostic value of computerized tomography has increased due to very rapid technical advances in both equipment and techniques. When the CT scanners were introduced, a significant problem for the specification of the radiation dose imparted to the patient undergoing CT examination has been created. In CT, the conditions of exposure are quite different from those in conventional X-ray imaging. CT procedure involves the continuous tomography of thin layers. Some of these layers touch each other while others overlap. The radiation doses received by patients can vary considerably. In addition to the radiation from the collimated primary beam, patients are exposed to significant scattered doses in unpredictable amounts. Every effort should be made to keep these doses to a reasonable minimum, without sacrificing the image quality. The aims of this work were to determine the surface doses delivered to various organs of patients during various computerized tomography examinations (head, thorax, kidney, abdomen and pelvis). Particular attention was directed to the precise determination of doses received by the eyes (during CT of head) and gonads (during CT of pelvis and lower abdomen) since these organs can be near or even in the primary X-ray beam

  6. SMART, Radiation Dose Rates on Cask Surface

    International Nuclear Information System (INIS)

    Yamakoshi, Hisao

    1989-01-01

    1 - Description of program or function: SMART calculates radiation dose rate at the center of each cask surface by using characteristic functions for radiation shielding ability and for radiation current back-scattered from cask wall and cask cavity of each cask, once cask-type is specified. 2 - Method of solution: Matrix Calculation

  7. Dose banding as an alternative to body surface area-based dosing of chemotherapeutic agents

    NARCIS (Netherlands)

    E. Chatelut (Etienne); M.L. White-Koning (M.); A.H.J. Mathijssen (Ron); F. Puisset (F.); S.D. Baker (Sharyn); A. Sparreboom (Alex)

    2012-01-01

    textabstractBackground: Dose banding is a recently suggested dosing method that uses predefined ranges (bands) of body surface area (BSA) to calculate each patients dose by using a single BSA-value per band. Thus, drugs with sufficient long-term stability can be prepared in advance. The main

  8. Radiochromic film as a radiotherapy surface-dose detector

    International Nuclear Information System (INIS)

    Butson, M.J.; Metcalfe, P.E.; Wollongong Univ., NSW; Mathur, J.N.

    1996-01-01

    Radiochromic film is shown to be a useful surface-dose detector for radiotherapy x-ray beams. Central-axis percentage surface-dose results as measured by Gafchromic film for a 6 MVp x-ray beam produced by a Varian 2100C Linac at 100 cm SSD are 16%, 25%, 35%, 41% for 10, 20, 30 and 40 cm square field sizes, respectively. Using a simple, uniform light source and a CCD camera connected to an image analysis system, quantitative 3D surface doses are accurately attainable in real time as either numerical data, a black-and-white image or a colour-enhanced image. (Author)

  9. Determination of surface dose rate for cloisonne using thermoluminescent dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Hengyuan, Zhao; Yulian, Zhang

    1985-07-01

    In this paper, the measuring method and results of surface dose rate of cloisonne using CaSO/sub 4/ Dy-Teflon foil dosimeter are described. The surface dose rate of all products are below 0.015 mrad/h. These products contain 42 sorts of jewelery and 20 sets of wares (such as vases, plates, ash-trays, etc.). Most of the data fall within the range of natural background. For comparison, some jewelery from Taiwan and 3 vases from Japan are measured. The highest surface dose rate of 0.78 mrad/h is due to the necklace jewelery from Taiwan.

  10. Measurements of dose on build-up region, surface dose and outlet dose by a 10 MeV Linear accelerator

    International Nuclear Information System (INIS)

    Souza, C.N. de; Khoury, H.J.

    1987-01-01

    The dose on buildup region and the surface dose for a 10 MeV photon beam from a linear acelerator (Mevatrom-74, Siemens) is studied. The influence of the tray of polycarbonate on the surface dose is determined. (M.A.C.) [pt

  11. Measurement of annual dose on porcelain using surface TLD method

    International Nuclear Information System (INIS)

    Xia Junding; Wang Weida; Leung, P.L.

    2001-01-01

    In order to improve accuracy of TL authentication test for porcelain, a method of measurement of annual dose using ultrathin (CaSO 4 :Tm) dosage layer on porcelain was studied. The TLD was placed on the part of porcelain without glaze. A comparison of measurement of annual dose for surface TLD, inside TLD and alpha counting on porcelain was made. The results show that this technique is suitable for measuring annual dose and improving accuracy of TL authentication test for both porcelain and pottery

  12. The Effect of Aquaplast on Surface Dose of Photon Beam

    International Nuclear Information System (INIS)

    Oh, Do Hoon; Bae, Hoon Sik

    1995-01-01

    Purpose : To evaluate the effect on surface dose due to Aquaplast used for immobilizing the patients with head and neck cancers in photon beam radiotherapy. Materials and Methods : To assess surface and buildup region dose for 6MV X-ray from linear accelerator(Siemens Mevatron 6740), we measured percent ionization value with the Markus chamber model 30-329 manufactured by PTW Frieburg and Capintec electrometer, model WK92. For measurement of surface ionization value, the chamber was embedded in 25 X 25 X 3 cm 3 acrylic phantom and set on 25 X 25 X 5 cm 3 , polystyrene phantom to allow adequate scattering. The measurements of percent depth ionization were made by placing the polystyrene layers of appropriate thickness over the chamber. The measurements were taken at 10 cm SSD for 5 X 5 cm 2 , 10 X 10 cm 2 , and 15 X 15 cm 2 field sizes, respectively. Placing the layer of Aquaplast over the chamber, the same procedures were repeated. We evaluated two types o Aquaplast: 1.6mm layer of original Aquaplast(manufactured by WFR Aquaplast Corp.) and transformed Aquaplast similar to moulded one for immobilizing the patients practically. We also measured surface ionization values with blocking tray in presence or absence of transformed Aquaplast. In calculating percent depth dose, we used the formula suggested by Gerbi and khan to correct over response of the Markus chamber. Results : The surface doses for open fields of 5 X 5 cm 2 , 10 X 10 cm 2 , 15 X 15 cm 2 were 7.9%, 13.6%, and 18.7% respectively. He original Aquaplast increased the surface doses upto 38.4%, 43.6% and 47.4% respectively. There were little differences in percent depth dose values beyond the depth of Dmax. Increasing field size, the blocking tray caused increase of the surface dose by 0.2%, 1.7%, 3.0% without Aquaplast, 0.2%, 1.9%, 3.7% with transformed Aquaplast, respectively. Conclusion : The original and transformed Aquaplast increased the surface dose moderately. The percent depth doses beyond Dmax

  13. Investigation of the Entrance Surface Dose and Dose to Different Organs in Lumbar Spine Imaging

    Directory of Open Access Journals (Sweden)

    Sina S

    2014-12-01

    Full Text Available Background: Dose assessment using proper dosimeters is especially important in radiation protection optimization and imaging justification in diagnostic radiology. Objective: The aim of this study is to obtain the Entrance Skin Dose (ESD of patients undergoing lumbar spine imaging using two thermoluminescence dosimeters TLD-100 (LiF: Mg, Ti and GR-200 (LiF: Mg, Cu, P and also to obtain the absorbed dose to different organs in lumbar spine imaging with several views. Methods: To measure the ESD values of the patients undergoing lumbar spine imaging, the two TLD types were put on their skin surface. The ESD values for different views of lumbar spine imaging were also measured by putting the TLDs at the surface of the Rando phantom. Several TLD chips were inserted inside different organs of Rando phantom to measure the absorbed dose to different organs in lumbar spine imaging. Results: The results indicate that there is a close agreement between the results of the two dosimeters. Based on the results of this experiment, the ESD dose of the 16 patients included in this study varied between 2.71 mGy and 26.29 mGy with the average of 11.89 mGy for TLD-100, and between 2.55 mGy and 27.41 mGy with the average of 12.32 mGy for GR-200 measurements. The ESDs obtained by putting the two types of TLDs at the surface of Rando phantom are in close agreement. Conclusion: According to the results, the GR200 has greater sensitivity than the TLD-100.

  14. Investigation of the Entrance Surface Dose and Dose to Different Organs in Lumbar Spine Imaging

    Science.gov (United States)

    Sina, S; Zeinali, B; Karimipoorfard, M; Lotfalizadeh, F; Sadeghi, M; Zamani, E; Faghihi, R

    2014-01-01

    Background: Dose assessment using proper dosimeters is especially important in radiation protection optimization and imaging justification in diagnostic radiology. Objective: The aim of this study is to obtain the Entrance Skin Dose (ESD) of patients undergoing lumbar spine imaging using two thermoluminescence dosimeters TLD-100 (LiF: Mg, Ti) and GR-200 (LiF: Mg, Cu, P) and also to obtain the absorbed dose to different organs in lumbar spine imaging with several views. Methods: To measure the ESD values of the patients undergoing lumbar spine imaging, the two TLD types were put on their skin surface. The ESD values for different views of lumbar spine imaging were also measured by putting the TLDs at the surface of the Rando phantom. Several TLD chips were inserted inside different organs of Rando phantom to measure the absorbed dose to different organs in lumbar spine imaging. Results: The results indicate that there is a close agreement between the results of the two dosimeters. Based on the results of this experiment, the ESD dose of the 16 patients included in this study varied between 2.71 mGy and 26.29 mGy with the average of 11.89 mGy for TLD-100, and between 2.55 mGy and 27.41 mGy with the average of 12.32 mGy for GR-200 measurements. The ESDs obtained by putting the two types of TLDs at the surface of Rando phantom are in close agreement. Conclusion: According to the results, the GR200 has greater sensitivity than the TLD-100. PMID:25599058

  15. Analysis on the entrance surface dose and contrast medium dose at computed tomography and angiography in cardiovascular examination

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Young Hyun [Dept. of Cardiovascular Center, Yeocheon Jeonnam Hospital, Yeosu (Korea, Republic of); Han, Jae Bok; Choi, Nam Gil; Song, Jong Nam [Dept. of Radiological Science, Dongshin University, Naju (Korea, Republic of)

    2016-12-15

    This study aimed to identify dose reduction measures by retrospectively analyzing the entrance surface dose at computed tomography and angiography in cardiovascular examination and to contribute the patients with renal impairmend and a high probability of side effects to determine the inspection's direction by measuring the contrast usages actually to active actions for the dose by actually measuring the contrast medium dose. The CTDIvol value and air kerma value, which are the entrance surface doses of the two examinations, and the contrast medium dose depending on the number of slides were compared and analyzed. This study was conducted in 21 subjects (11 males; 10 females) who underwent Cardiac Computed Tomographic Angiography (CCTA) and Coronary Angiography (CAG) in this hospital during the period from May 2014 to May 2016. The subject's age was 48-85 years old (mean 65±10 years old), and the weight was 37.6~83.3 kg (mean 63±6 kg). Dose reduction could be expected in the cardiovascular examination using CCTA rather than in the examination using CAG. In terms of contrast medium dose, CAG used a smaller dose than CCTA. In particular, as the number of slides increases at CAG, the contrast medium dose increases. Therefore, in order to reduce the contrast medium dose, the number of slides suitable for the scan range must be selected.

  16. Surface doses under head and neck immobilisation devices

    International Nuclear Information System (INIS)

    Baveas, E.

    2004-01-01

    Full text: Methods using ion chambers, TLDs and film were developed to measure the skin-sparing properties of three head and neck immobilisation devices used in radiation therapy, viz. Sinmed multi-perforated and micro-perforated posicast thermoplastic masks (used with a supporting carbon fibre back support), and a Kablite vacuum-formed shell plastic mask (used with a Perspex back support). All measurements were performed with 6 MV beams from Elekta Precise linear accelerators. Two situations have been considered in this study. In the first situation, phantom surface doses under the flat unmoulded mask and back-support materials lying on the surface of a 'solid water' phantom were measured with parallel plate ion chambers and correlated with the physical properties of the materials. In the second situation a particular head and neck treatment technique was adopted and the treatment planned on an anthropomorphic tissue-equivalent phantom. The clinical setup consisted of a wedged pair to the right parotid, planned to deliver a reference dose of 63 Gy to the isocentre, plus an anterior supraclavicular field planned to deliver a reference dose of 50 Gy at a depth of 2 cm. The 3 immobilisation masks were each moulded to the anthropomorphic tissue-equivalent phantom. TLD chips were used to measure the phantom skin dose at a set of 18 locations under each of the 3 immobilisation masks and also without an immobilisation device. The results clearly demonstrate the extent to which the various immobilisation devices increase the surface dose. Results for the first situation are summarised. The averages of the doses recorded by the TLDs in three separate regions for the second situation are shown in Table 2. The combined results show that the areal density of the unmoulded mask materials correlates with the surface dose these materials produce before moulding, but this correlation is lost after moulding for the clinical situation considered. This change upon moulding is

  17. Tungsten and carbon surface change under high dose plasma exposure

    International Nuclear Information System (INIS)

    Martynenko, Y.V.; Khripunov, B.I.; Petrov, V.B.

    2009-01-01

    Study of surface composition dynamics has been made on the LENTA linear plasma simulator. Experiments have been made on tungsten and carbon materials subjected to steady-state plasma exposure. The achieved ion doses on the surface were 10 21 ion cm -2 . WL 10 tungsten containing 1% of La2O3 oxide and titanium-doped graphite RG-T were studied. The following experimental conditions were varied in these experiments: energy of ions, surface temperature, working gas. Irradiations of tungsten WL 10 were executed in deuterium plasma at low ion energies (about 20 eV) and at 200 eV for temperatures below 340 K. Graphite RG-T was exposed at 1300 K. Elevated surface temperature (about 1050K) was also characteristic of experiments on tungsten sample under nitrogen plasma impact (simulated inter-ELMs condition). Surface microstructure modification has been observed and surface composition changes were found on the materials showing influence of high dose plasma irradiations on element redistribution in the near surface layers. (author)

  18. Entrance surface dose measurements in mammography using thermoluminescence technique

    International Nuclear Information System (INIS)

    Rivera, T.; Vega C, H.R.; Manzanares A, E; Azorin, J.; Gonzalez, P.R.

    2007-01-01

    Full text: Of the various techniques that can be used for personnel dosimetry, thermoluminescence dosimetry (TLD) has emerged as a superior technique due to its manifold advantages over other methods of dose estimation. Various phosphors have been therefore investigated regarding their suitability for dosimetry. In this paper, a dosimetry system based on thermally stimulated luminescence (TSL) from zirconium oxide phosphors embedded in polytetrafluorethylene (ZrO 2 +PTFE) was developed for entrance surface doses (ES) measurements in mammography. Small ZrO 2 pellets of 5 mm in diameter and 0.8 mm in thickness were used. The reproducibility of measurements and linearity of ZrO 2 were also studied. The results were compared with those obtained from LiF:Mg,Cu,P usually used for the determination of absorbed dose in mammography. Measurements both per unit air kerma and In vivo were performed using a mammography unit model DMR (General Electric). The results showed that ZrO 2 TLDs can be used for the same X-ray dosimetry applications as LiF:Mg,Cu,P, with each type having the disadvantage of a response dependent on energy, particularly at low energies. These results indicate a considerable potential for use in routine control and In vivo ES measurements in mammography. (Author)

  19. Tracheobronchial and Alveolar Particle Surface Area Doses in Smokers

    Directory of Open Access Journals (Sweden)

    Fernanda Carmen Fuoco

    2017-01-01

    Full Text Available Cigarette smoke is the main cause of lung cancer events. Mainstream cigarette smoke (MSS is a direct concern for smokers, but also the secondhand smoke (SHS contributes to the smoker exposure. In addition, smoker exposure is affected by the “free-smoke” particle exposure (B, related to the micro-environments where smokers spend time. The aim of this paper is to evaluate the daily alveolar and tracheobronchial deposited fractions of airborne particles for smokers as the sum of these three contributions: MSS, SHS, and B. Measurements of particle surface area distributions in the MSS were performed through a Scanning Mobility Particle Sizer, an Aerodynamic Particle Sizer, and a Thermo-dilution system on five types of conventional cigarettes. A Monte Carlo method was then applied to evaluate the most probable value of dose received during the inhalation of MSS by smokers. Measurements of particle concentrations in SHS and at the “free-smoke” particle background (B were performed through 24-h monitoring at a personal scale of adult smoker through hand-held devices. This paper found that the total daily deposited dose for typical smokers was 1.03 × 105 mm2·day−1. The main contribution of such a huge daily dose was addressable to the MSS (98% while SHS contributed 1.1%, increasing up to 2% for people smoking only while traveling in a car.

  20. Radiotherapy high energy surface dose measurements: effects of chamber polarity

    International Nuclear Information System (INIS)

    Cheung, T.; Yu, P.K.N.; Butson, M.J.; Cancer Services, Wollongong, NSW

    2004-01-01

    Full text: The effects of chamber polarity have been investigated for the measurement of 6MV and 18MV x-ray surface dose using a parallel plate ionization chamber. Results have shown that a significant difference in measured ionization is recorded between to polarities at 6MV and 18MV at the phantom surface. A polarity ratio ranging from 1 062 to 1 005 is seen for 6MV x-rays at the phantom surface for field sizes 5cm x 5cm to 40cm x 40cm when comparing positive to negative polarity. These ratios range from 1.024 to 1.004 for 18MV x-rays with the same field sizes. When these charge reading are compared to the D max readings of the same polarity it is found that these polarity effects are minimal for the calculation of percentage dose results with variations being less than 1% of maximum. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  1. Entrance surface dose measurements in pediatric radiological examinations

    International Nuclear Information System (INIS)

    Ribeiro, L.A.; Yoshimura, E.M.

    2008-01-01

    A survey of pediatric radiological examinations was carried out in a reference pediatric hospital of the city of Sao Paulo, in order to investigate the doses to children undergoing conventional X-ray examinations. The results showed that the majority of pediatric patients are below 4 years, and that about 80% of the examinations correspond to chest projections. Doses to typical radiological examinations were measured in vivo with thermoluminescent dosimeters (LiF: Mg, Ti and LiF: Mg, Cu, P) attached to the skin of the children to determine entrance surface dose (ESD). Also homogeneous phantoms were used to obtain ESD to younger children, because the technique uses a so small kVp that the dosimeters would produce an artifact image in the patient radiograph. Four kinds of pediatric examinations were investigated: three conventional examinations (chest, skull and abdomen) and a fluoroscopic procedure (barium swallow). Relevant information about kVp and mAs values used in the examinations was collected, and we discuss how these parameters can affect the ESD. The ESD values measured in this work are compared to reference levels published by the European Commission for pediatric patients. The results obtained (third-quartile of the ESD distribution) for chest AP examinations in three age groups were: 0.056 mGy (2-4 years old); 0.068 mGy (5-9 years old); 0.069 mGy (10-15 years old). All of them are below the European reference level (0.100 mGy). ESD values measured to the older age group in skull and abdomen AP radiographs (mean values 3.44 and 1.20 mGy, respectively) are above the European reference levels (1.5 mGy to skull and 1.0 mGy to abdomen). ESD values measured in the barium swallow examination reached 10 mGy in skin regions corresponding to thyroid and esophagus. It was noticed during this survey that some technicians use, improperly, X-ray fluoroscopy in conventional examinations to help them in positioning the patient. The results presented here are a

  2. Evaluation of the Entrance Surface Dose (ESD and Radiation Dose to the Radiosensitive Organs in Pediatric Pelvic Radiography

    Directory of Open Access Journals (Sweden)

    Vahid Karami

    2017-06-01

    Full Text Available Background Patients' dosimetry is crucial in order to enhance radiation protection optimization and to deliver low radiation dose to the patients in a radiological procedure. The aim of this study was to assess the entrance surface dose (ESD and radiation dose to the radiosensitive organs in pediatric pelvic radiography. Materials and Methods The studied population included 98 pediatric patients of both genders referred to anteroposterior (AP projection of pelvic radiography. The radiation dose was directly measured using high radiosensitive cylindrical lithium fluoride thermo-luminescent dosimeters (TLD-GR200. Two TLDs were placed at the center point of the radiation field to measure the ESD of pelvis. Moreover for each patient, 2 TLDs were placed upon each eyelid, 2 TLDs upon each breast, 2 TLDs upon the surface anatomical position of the thyroid gland and finally 2 TLDs at the surface anatomical position of the gonads to measure the received dose. Results The ESD ± standard deviation for AP pelvic radiography was obtained 591.7±76 µGy. Statistically significant difference was obtained between organs located outside and inside of the radiation field with respect to dose received (P

  3. The survey of the surface doses of the dental x-ray machines

    International Nuclear Information System (INIS)

    Lee, Jae Seo; Kang, Byung Cheol; Yoon, Suk Ja

    2005-01-01

    The purpose of this study was to investigate variability of doses with same exposure parameters and evaluate radiographic density according to the variability of doses. Twenty-eight MAX-GLS (Shinhung Co, Seoul, Korea), twenty-one D-60-S (DongSeo Med, Seoul, Korea), and eleven REX-601 (Yoshida Dental MFG, Tokyo, Japan) dental x-ray machines were selected for this study. Surface doses were measured under selected combinations of tube voltage, tube current, exposure time, and constant distance 42 cm from the focal spot to the surface of the Multi-O-meter (Unfors Instrument, Billdal, Sweden). Radiographic densities were measured on the films at maximum, minimum and mean surface doses of each brand of x-ray units. With MAX-GLS, the maximum surface doses were thirteen to fourteen times as much as the minimum surfaces doses. With D-60-S, the maximum surface doses were three to eight times as much as the minimum surface doses. With REX-601, the maximum surface doses were six to ten times as much as the minimum surface doses. The differences in radiographic densities among maximum, mean, and minimum doses were significant (p<0.01). The surface exposure doses of each x-ray machine at the same exposure parameters were different within the same manufacturer's machines.

  4. Entrance surface dose in cerebral interventional radiology procedures

    International Nuclear Information System (INIS)

    Barrera-Rico, M.; López-Rendón, X.; Rivera-Ordóñez, C. E.; Gamboa-deBuen, I.

    2012-01-01

    At the Instituto Nacional de Neurología y Neurocirugía (INNN) diagnostic as well as therapeutic procedures of interventional radiology are carried out. Since the procedures can last from some minutes to several hours, the absorbed dose for the patient could increase dangerously. An investigation had begun in order to determine the entrance surface dose (ESD) using 25 thermoluminiscent dosimeters TLD-100 and 8 strips of 15 ×1 cm 2 of Gafchromic XR-QA2 film bound in a holder of 15×15 cm 2 in the posteroanterior (PA) and lateral (LAT) positions during all the procedure. The results show that maximum ESD could be from 0.9 to 2.9 Gy for the PA position and between 1.6 and 2.5 Gy for the lateral position. The average ESD was between 0.7 and 1.3 Gy for the PA position, and from 0.44 to 1.1 Gy for the lateral position in a therapeutic procedure.

  5. Entrance surface dose in cerebral interventional radiology procedures

    Energy Technology Data Exchange (ETDEWEB)

    Barrera-Rico, M.; Lopez-Rendon, X.; Rivera-Ordonez, C. E.; Gamboa-deBuen, I. [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, 04510 DF (Mexico); Instituto Nacional de Neurologia y Neurocirugia Manuel Velasco Suarez, 14269 DF (Mexico); Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, 04510 DF (Mexico)

    2012-10-23

    At the Instituto Nacional de Neurologia y Neurocirugia (INNN) diagnostic as well as therapeutic procedures of interventional radiology are carried out. Since the procedures can last from some minutes to several hours, the absorbed dose for the patient could increase dangerously. An investigation had begun in order to determine the entrance surface dose (ESD) using 25 thermoluminiscent dosimeters TLD-100 and 8 strips of 15 Multiplication-Sign 1 cm{sup 2} of Gafchromic XR-QA2 film bound in a holder of 15 Multiplication-Sign 15 cm{sup 2} in the posteroanterior (PA) and lateral (LAT) positions during all the procedure. The results show that maximum ESD could be from 0.9 to 2.9 Gy for the PA position and between 1.6 and 2.5 Gy for the lateral position. The average ESD was between 0.7 and 1.3 Gy for the PA position, and from 0.44 to 1.1 Gy for the lateral position in a therapeutic procedure.

  6. Surface sputtering in high-dose Fe ion implanted Si

    International Nuclear Information System (INIS)

    Ishimaru, Manabu

    2007-01-01

    Microstructures and elemental distributions in high-dose Fe ion implanted Si were characterized by means of transmission electron microscopy and Rutherford backscattering spectroscopy. Single crystalline Si(0 0 1) substrates were implanted at 350 deg. C with 120 keV Fe ions to fluences ranging from 0.1 x 10 17 to 4.0 x 10 17 /cm 2 . Extensive damage induced by ion implantation was observed inside the substrate below 1.0 x 10 17 /cm 2 , while a continuous iron silicide layer was formed at 4.0 x 10 17 /cm 2 . It was found that the spatial distribution of Fe projectiles drastically changes at the fluence between 1.0 x 10 17 and 4.0 x 10 17 /cm 2 due to surface sputtering during implantation

  7. Total effective dose equivalent associated with fixed uranium surface contamination

    International Nuclear Information System (INIS)

    Bogard, J.S.; Hamm, R.N.; Ashley, J.C.; Turner, J.E.; England, C.A.; Swenson, D.E.; Brown, K.S.

    1997-04-01

    This report provides the technical basis for establishing a uranium fixed-contamination action level, a fixed uranium surface contamination level exceeding the total radioactivity values of Appendix D of Title 10, Code of Federal Regulations, part 835 (10CFR835), but below which the monitoring, posting, and control requirements for Radiological Areas are not required for the area of the contamination. An area of fixed uranium contamination between 1,000 dpm/100 cm 2 and that level corresponding to an annual total effective dose equivalent (TEDE) of 100 mrem requires only routine monitoring, posting to alert personnel of the contamination, and administrative control. The more extensive requirements for monitoring, posting, and control designated by 10CFR835 for Radiological Areas do not have to be applied for these intermediate fixed-contamination levels

  8. SU-E-T-196: Comparative Analysis of Surface Dose Measurements Using MOSFET Detector and Dose Predicted by Eclipse - AAA with Varying Dose Calculation Grid Size

    Energy Technology Data Exchange (ETDEWEB)

    Badkul, R; Nejaiman, S; Pokhrel, D; Jiang, H; Kumar, P [University of Kansas Medical Center, Kansas City, KS (United States)

    2015-06-15

    Purpose: Skin dose can be the limiting factor and fairly common reason to interrupt the treatment, especially for treating head-and-neck with Intensity-modulated-radiation-therapy(IMRT) or Volumetrically-modulated - arc-therapy (VMAT) and breast with tangentially-directed-beams. Aim of this study was to investigate accuracy of near-surface dose predicted by Eclipse treatment-planning-system (TPS) using Anisotropic-Analytic Algorithm (AAA)with varying calculation grid-size and comparing with metal-oxide-semiconductor-field-effect-transistors(MOSFETs)measurements for a range of clinical-conditions (open-field,dynamic-wedge, physical-wedge, IMRT,VMAT). Methods: QUASAR™-Body-Phantom was used in this study with oval curved-surfaces to mimic breast, chest wall and head-and-neck sites.A CT-scan was obtained with five radio-opaque markers(ROM) placed on the surface of phantom to mimic the range of incident angles for measurements and dose prediction using 2mm slice thickness.At each ROM, small structure(1mmx2mm) were contoured to obtain mean-doses from TPS.Calculations were performed for open-field,dynamic-wedge,physical-wedge,IMRT and VMAT using Varian-21EX,6&15MV photons using twogrid-sizes:2.5mm and 1mm.Calibration checks were performed to ensure that MOSFETs response were within ±5%.Surface-doses were measured at five locations and compared with TPS calculations. Results: For 6MV: 2.5mm grid-size,mean calculated doses(MCD)were higher by 10%(±7.6),10%(±7.6),20%(±8.5),40%(±7.5),30%(±6.9) and for 1mm grid-size MCD were higher by 0%(±5.7),0%(±4.2),0%(±5.5),1.2%(±5.0),1.1% (±7.8) for open-field,dynamic-wedge,physical-wedge,IMRT,VMAT respectively.For 15MV: 2.5mm grid-size,MCD were higher by 30%(±14.6),30%(±14.6),30%(±14.0),40%(±11.0),30%(±3.5)and for 1mm grid-size MCD were higher by 10% (±10.6), 10%(±9.8),10%(±8.0),30%(±7.8),10%(±3.8) for open-field, dynamic-wedge, physical-wedge, IMRT, VMAT respectively.For 6MV, 86% and 56% of all measured values

  9. Dose limits

    International Nuclear Information System (INIS)

    Fitoussi, L.

    1987-12-01

    The dose limit is defined to be the level of harmfulness which must not be exceeded, so that an activity can be exercised in a regular manner without running a risk unacceptable to man and the society. The paper examines the effects of radiation categorised into stochastic and non-stochastic. Dose limits for workers and the public are discussed

  10. Surface dose measurements in and out of field. Implications for breast radiotherapy with megavoltage photon beams

    Energy Technology Data Exchange (ETDEWEB)

    Lonski, Peta; Kron, Tomas [Peter MacCallum Cancer Centre, Melbourne (Australia); RMIT Univ., Melbourne (Australia); Ramachandran, Prabhakar; Franich, Rick [Peter MacCallum Cancer Centre, Melbourne (Australia)

    2017-07-01

    This study examines the difference in surface dose between flat and flattening filter free (FFF) photon beams in the context of breast radiotherapy. The surface dose was measured for 6 MV, 6 MV FFF, 10 MV, 10 MV FFF and 18 MV photon beams using a thin window ionisation chamber for various field sizes. Profiles were acquired to ascertain the change in surface dose off-axis. Out-of-field measurements were included in a clinically representative half beam block tangential breast field. In the field centres of FFF beams the surface dose was found to be increased for small fields and decreased for large fields compared to flat beams. For FFF beams, surface dose was found to decrease off-axis and resulted in lower surface dose out-of-field compared to flat beams.

  11. Controllable dose

    International Nuclear Information System (INIS)

    Alvarez R, J.T.; Anaya M, R.A.

    2004-01-01

    With the purpose of eliminating the controversy about the lineal hypothesis without threshold which found the systems of dose limitation of the recommendations of ICRP 26 and 60, at the end of last decade R. Clarke president of the ICRP proposed the concept of Controllable Dose: as the dose or dose sum that an individual receives from a particular source which can be reasonably controllable by means of any means; said concept proposes a change in the philosophy of the radiological protection of its concern by social approaches to an individual focus. In this work a panorama of the foundations is presented, convenient and inconveniences that this proposal has loosened in the international community of the radiological protection, with the purpose of to familiarize to our Mexican community in radiological protection with these new concepts. (Author)

  12. SU-E-T-577: Obliquity Factor and Surface Dose in Proton Beam Therapy

    International Nuclear Information System (INIS)

    Das, I; Andersen, A; Coutinho, L

    2015-01-01

    Purpose: The advantage of lower skin dose in proton beam may be diminished creating radiation related sequalae usually seen with photon and electron beams. This study evaluates the surface dose as a complex function of beam parameters but more importantly the effect of beam angle. Methods: Surface dose in proton beam depends on the beam energy, source to surface distance, the air gap between snout and surface, field size, material thickness in front of surface, atomic number of the medium, beam angle and type of nozzle (ie double scattering, (DS), uniform scanning (US) or pencil beam scanning (PBS). Obliquity factor (OF) is defined as ratio of surface dose in 0° to beam angle Θ. Measurements were made in water phantom at various beam angles using very small microdiamond that has shown favorable beam characteristics for high, medium and low proton energy. Depth dose measurements were performed in the central axis of the beam in each respective gantry angle. Results: It is observed that surface dose is energy dependent but more predominantly on the SOBP. It is found that as SSD increases, surface dose decreases. In general, SSD, and air gap has limited impact in clinical proton range. High energy has higher surface dose and so the beam angle. The OF rises with beam angle. Compared to OF of 1.0 at 0° beam angle, the value is 1.5, 1.6, 1,7 for small, medium and large range respectively for 60 degree angle. Conclusion: It is advised that just like range and SOBP, surface dose should be clearly understood and a method to reduce the surface dose should be employed. Obliquity factor is a critical parameter that should be accounted in proton beam therapy and a perpendicular beam should be used to reduce surface dose

  13. Analysis of Surface Dose Refer to Distance between Beam Spoiler and Patient in Total Body Irradiation

    International Nuclear Information System (INIS)

    Choi, Jong Hwan; Kim, Jong Sik; Choi, Ji Min; Shin, Eun Hyuk; Song, Ki Won; Park, Young Hwan

    2007-01-01

    Total body irradiation is used to kill the total malignant cell and for immunosuppression component of preparatory regimens for bone-marrow restitution of patients. Beam spoiler is used to increase the dose to the superficial tissues. This paper finds the property of the distance between beam spoiler and patient. Set-up conditions are 6 MV-Xray, 300 MU, SAD = 400 cm, field size = 40 x 40 cm 2 . The parallel plate chamber located in surface, midpoint and exit of solid water phantom. The surface dose is measured while the distance between beam spoiler and patient is altered. Because it should be found proper distance. The solid water phantom is fixer and beam spoiler is moving. Central dose of phantom is 10.7 cGy and exit dose is 6.7 cGy. In case of distance of 50 cm to 60 cm between beam spoiler and solid water phantom, incidence dose is 14.58-14.92 cGy. Therefore, The surface dose was measured 99.4-101% with got near most to the prescription dose. In clinical case, distance between beam spoiler and patient affect surface dose. If once 50-60 cm of distance between beam spoiler and patient, surface dose of patient got near prescription dose. It would be taken distance between beam spoiler and patient into account in clinical therapy.

  14. Can radiation therapy treatment planning system accurately predict surface doses in postmastectomy radiation therapy patients?

    International Nuclear Information System (INIS)

    Wong, Sharon; Back, Michael; Tan, Poh Wee; Lee, Khai Mun; Baggarley, Shaun; Lu, Jaide Jay

    2012-01-01

    Skin doses have been an important factor in the dose prescription for breast radiotherapy. Recent advances in radiotherapy treatment techniques, such as intensity-modulated radiation therapy (IMRT) and new treatment schemes such as hypofractionated breast therapy have made the precise determination of the surface dose necessary. Detailed information of the dose at various depths of the skin is also critical in designing new treatment strategies. The purpose of this work was to assess the accuracy of surface dose calculation by a clinically used treatment planning system and those measured by thermoluminescence dosimeters (TLDs) in a customized chest wall phantom. This study involved the construction of a chest wall phantom for skin dose assessment. Seven TLDs were distributed throughout each right chest wall phantom to give adequate representation of measured radiation doses. Point doses from the CMS Xio® treatment planning system (TPS) were calculated for each relevant TLD positions and results correlated. There were no significant difference between measured absorbed dose by TLD and calculated doses by the TPS (p > 0.05 (1-tailed). Dose accuracy of up to 2.21% was found. The deviations from the calculated absorbed doses were overall larger (3.4%) when wedges and bolus were used. 3D radiotherapy TPS is a useful and accurate tool to assess the accuracy of surface dose. Our studies have shown that radiation treatment accuracy expressed as a comparison between calculated doses (by TPS) and measured doses (by TLD dosimetry) can be accurately predicted for tangential treatment of the chest wall after mastectomy.

  15. Surface dose measurements and comparison of unflattened and flattened photon beams

    Directory of Open Access Journals (Sweden)

    Ashokkumar Sigamani

    2016-01-01

    Full Text Available The purpose of this study was to evaluate the central axis dose in the build-up region and the surface dose of a 6 MV and 10 MV flattened photon beam (FB and flattening filter free (FFF therapeutic photon beam for different square field sizes (FSs for a Varian Truebeam linear accelerator using parallel-plate ionization chamber and Gafchromic film. Knowledge of dosimetric characteristics in the build-up region and surface dose of the FFF is essential for clinical care. The dose measurements were also obtained empirically using two different commonly used dosimeters: a p-type photon semiconductor dosimeter and a cylindrical ionization chamber. Surface dose increased linearly with FS for both FB and FFF photon beams. The surface dose values of FFF were higher than the FB FSs. The measured surface dose clearly increases with increasing FS. The FFF beams have a modestly higher surface dose in the build-up region than the FB. The dependence of source to skin distance (SSD is less significant in FFF beams when compared to the flattened beams at extended SSDs.

  16. Dose and dose rate monitor

    International Nuclear Information System (INIS)

    Novakova, O.; Ryba, J.; Slezak, V.; Svobodova, B.; Viererbl, L.

    1984-10-01

    The methods are discussea of measuring dose rate or dose using a scintillation counte. A plastic scintillator based on polystyrene with PBD and POPOP activators and coated with ZnS(Ag) was chosen for the projected monitor. The scintillators were cylindrical and spherical in shape and of different sizes; black polypropylene tubes were chosen as the best case for the probs. For the counter with different plastic scintillators, the statistical error 2σ for natural background was determined. For determining the suitable thickness of the ZnS(Ag) layer the energy dependence of the counter was measured. Radioisotopes 137 Cs, 241 Am and 109 Cd were chosen as radiation sources. The best suited ZnS(Ag) thickness was found to be 0.5 μm. Experiments were carried out to determine the directional dependence of the detector response and the signal to noise ratio. The temperature dependence of the detector response and its compensation were studied, as were the time stability and fatigue manifestations of the photomultiplier. The design of a laboratory prototype of a dose rate and dose monitor is described. Block diagrams are given of the various functional parts of the instrument. The designed instrument is easiiy portable, battery powered, measures dose rates from natural background in the range of five orders, i.e., 10 -2 to 10 3 nGy/s, and allows to determine a dose of up to 10 mGy. Accouracy of measurement in the energy range of 50 keV to 1 MeV is better than +-20%. (E.S.)

  17. Dose distribution considerations of medium energy electron beams at extended source-to-surface distance

    International Nuclear Information System (INIS)

    Saw, Cheng B.; Ayyangar, Komanduri M.; Pawlicki, Todd; Korb, Leroy J.

    1995-01-01

    Purpose: To determine the effects of extended source-to-surface distance (SSD) on dose distributions for a range of medium energy electron beams and cone sizes. Methods and Materials: The depth-dose curves and isodose distributions of 6 MeV, 10 MeV, and 14 MeV electron beams from a dual photon and multielectron energies linear accelerator were studied. To examine the influence of cone size, the smallest and the largest cone sizes available were used. Measurements were carried out in a water phantom with the water surface set at three different SSDs from 101 to 116 cm. Results: In the region between the phantom surface and the depth of maximum dose, the depth-dose decreases as the SSD increases for all electron beam energies. The effects of extended SSD in the region beyond the depth of maximum dose are unobservable and, hence, considered minimal. Extended SSD effects are apparent for higher electron beam energy with small cone size causing the depth of maximum dose and the rapid dose fall-off region to shift deeper into the phantom. However, the change in the depth-dose curve is small. On the other hand, the rapid dose fall-off region is essentially unaltered when the large cone is used. The penumbra enlarges and electron beam flatness deteriorates with increasing SSD

  18. Analysis of surface absorbed dose in X-ray grating interferometry

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zhili, E-mail: wangnsrl@ustc.edu.cn [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230026 (China); Wu, Zhao; Gao, Kun; Wang, Dajiang; Chen, Heng; Wang, Shenghao [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230026 (China); Wu, Ziyu, E-mail: wuzy@ustc.edu.cn [National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230026 (China); Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)

    2014-10-15

    Highlights: • Theoretical framework for dose estimation in X-ray grating interferometry. • Potential dose reduction of X-ray grating interferometry compared to conventional radiography. • Guidelines for optimization of X-ray grating interferometry for dose-sensitive applications. • Measure to compare various existing X-ray phase contrast imaging techniques. - Abstract: X-ray phase contrast imaging using grating interferometry has shown increased contrast over conventional absorption imaging, and therefore the great potential of dose reduction. The extent of the dose reduction depends on the geometry of grating interferometry, the photon energy, the properties of the sample under investigation and the utilized detector. These factors also determine the capability of grating interferometry to distinguish between different tissues with a specified statistical certainty in a single raw image. In this contribution, the required photon number for imaging and the resulting surface absorbed dose are determined in X-ray grating interferometry, using a two-component imaging object model. The presented results confirm that compared to conventional radiography, phase contrast imaging using grating interferometry indeed has the potential of dose reduction. And the extent of dose reduction is strongly dependent on the imaging conditions. Those results provide a theoretical framework for dose estimation under given imaging conditions before experimental trials, and general guidelines for optimization of grating interferometry for those dose-sensitive applications.

  19. Analysis of surface absorbed dose in X-ray grating interferometry

    International Nuclear Information System (INIS)

    Wang, Zhili; Wu, Zhao; Gao, Kun; Wang, Dajiang; Chen, Heng; Wang, Shenghao; Wu, Ziyu

    2014-01-01

    Highlights: • Theoretical framework for dose estimation in X-ray grating interferometry. • Potential dose reduction of X-ray grating interferometry compared to conventional radiography. • Guidelines for optimization of X-ray grating interferometry for dose-sensitive applications. • Measure to compare various existing X-ray phase contrast imaging techniques. - Abstract: X-ray phase contrast imaging using grating interferometry has shown increased contrast over conventional absorption imaging, and therefore the great potential of dose reduction. The extent of the dose reduction depends on the geometry of grating interferometry, the photon energy, the properties of the sample under investigation and the utilized detector. These factors also determine the capability of grating interferometry to distinguish between different tissues with a specified statistical certainty in a single raw image. In this contribution, the required photon number for imaging and the resulting surface absorbed dose are determined in X-ray grating interferometry, using a two-component imaging object model. The presented results confirm that compared to conventional radiography, phase contrast imaging using grating interferometry indeed has the potential of dose reduction. And the extent of dose reduction is strongly dependent on the imaging conditions. Those results provide a theoretical framework for dose estimation under given imaging conditions before experimental trials, and general guidelines for optimization of grating interferometry for those dose-sensitive applications

  20. The calculation of the surface dose in examinations following cardiac catheterization

    International Nuclear Information System (INIS)

    Ewen, K.

    1995-01-01

    It is inevitable in examinations requiring patient exposure to high doses that the investigators and medical assistants receive high wholebody doses on account of fray radiation and, occasionally, also high partial body doses (hands) on account of the useful beam range. A number of different circumstances are adding up to create this extreme situation. In this connection, a mathematical method for the calculation of the surface dose (cutaneous dose rate) is described that is based on sets of parameters commonly used in diagnostic radiology: Set I of parameters: Tube voltage - current strength of tube - distance between focus and skin; - set II of parameters: Incidence dose rate of image intensifier - distance between focus and skin -distance between image intensifier and plane of ray incidence (skin). (orig./VHE) [de

  1. Comparison of surface doses from spot scanning and passively scattered proton therapy beams

    International Nuclear Information System (INIS)

    Arjomandy, Bijan; Sahoo, Narayan; Gillin, Michael; Cox, James; Lee, Andrew

    2009-01-01

    Proton therapy for the treatment of cancer is delivered using either passively scattered or scanning beams. Each technique delivers a different amount of dose to the skin, because of the specific feature of their delivery system. The amount of dose delivered to the skin can play an important role in choosing the delivery technique for a specific site. To assess the differences in skin doses, we measured the surface doses associated with these two techniques. For the purpose of this investigation, the surface doses in a phantom were measured for ten prostate treatment fields planned with passively scattered proton beams and ten patients planned with spot scanning proton beams. The measured doses were compared to evaluate the differences in the amount of skin dose delivered by using these techniques. The results indicate that, on average, the patients treated with spot scanning proton beams received lower skin doses by an amount of 11.8% ± 0.3% than did the patients treated with passively scattered proton beams. That difference could amount to 4 CGE per field for a prescribed dose of 76 CGE in 38 fractions treated with two equally weighted parallel opposed fields. (note)

  2. Clinical meaning of radiodermatitis considering the surface dose of supervoltage electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Hiraki, T [Kanazawa Univ. (Japan). School of Paramedicine; Rikimaru, S; Kakishita, M; Kuranishi, M

    1975-12-01

    In our experience using supervoltage betatron electron beam, the skin surface dose of the electron decreased when the energy became either greater or less than 18 MeV. When we considered 18 MeV to be a 100% dose, the dose with 4 MeV, which was the least amount, corresponded to 81% of the dose. The skin surface dose of 10 MeV betatron electrons or more became greater than the 90% standard tumor dose. An external irradiation of more than 10 MeV should not be applied to neoplasms of which the curative ratio is less than 1.0. Therefore another methods such as intraoperative irradiation, should be used. The surface skin dose about 4 to 6 MeV betatron postoperative irradiation, particularly after resection of breast cancer, was less than the skin dose with 10 MeV. Close care should be taken to prevent hot lesions which are caused by duplication of irradiation fields. It should be kept in mind that the late effects of hot lesions caused by electron beam irradiation with an energy of 10 MeV or more are serious.

  3. The clinical meaning of radiodermatitis considering the surface dose of supervoltage electron beam

    International Nuclear Information System (INIS)

    Hiraki, Tatsunosuke; Rikimaru, Shigeho; Kakishita, Masao; Kuranishi, Makoto.

    1975-01-01

    In our experience using supervoltage betatron electron beam, the skin surface dose of the electron decreased when the energy became either greater of less than 18 MeV. When we considered 18 MeV to be a 100% dose, the dose with 4 MeV, which was the least amount, corresponded to 81% of the dose. The skin surface dose of 10 MeV betatron electrons or more became greater than the 90% standard tumor dose. An external irradiation of more than 10 MeV should not be applied to neoplasms of which the curative ratio is less than 1.0. Therefore another methods such as intraoperative irradiation, should be used. The surface skin dose about 4-6 MeV betatron postoperative irradiation, particularly after resection of breast cancer, was less than the skin dose with 10 MeV. Close care should be taken to prevent hot lesions which are caused by duplication of irradiation fields. It should be kept in mind that the late effects of hot lesions caused by electron beam irradiation with an energy of 10 MeV or more are serious. (Kashu, E.)

  4. SU-F-18C-12: On the Relationship of the Weighted Dose to the Surface Dose In Abdominal CT - Patient Size Dependency

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Y; Scott, A; Allahverdian, J [Cedars-Sinai Medical Center, Los Angeles, CA (United States)

    2014-06-15

    Purpose: It is possible to measure the patient surface dose non-invasively using radiolucent dosimeters. However, the patient size specific weighted dose remains unknown. We attempted to study the weighted dose to surface dose relationship as the patient size varies in abdominal CT. Methods: Seven abdomen phantoms (CIRS TE series) simulating patients from an infant to a large adult were used. Size specific doses were measured with a 100 mm CT chamber under axial scans using a Siemens Sensation 64 (mCT) and a GE 750 HD. The scanner settings were 120 kVp, 200 mAs with fully opened collimations. Additional kVps (80, 100, 140) were added depending on the phantom sizes. The ratios (r) of the weighted CT dose (Dw) to the surface dose (Ds) were related to the phantom size (L) defined as the diameter resulting the equivalent cross-sectional area. Results: The Dw versus Ds ratio (r) was fitted to a linear relationship: r = 1.083 − 0.007L (R square = 0.995), and r = 1.064 − 0.007L (R square = 0.953), for Siemens Sensation 64 and GE 750 HD, respectively. The relationship appears to be independent of the scanner specifics. Conclusion: The surface dose to the weighted dose ratio decreases linearly as the patient size increases. The result is independent of the scanner specifics. The result can be used to obtain in vivo CT dosimetry in abdominal CT.

  5. SU-F-18C-12: On the Relationship of the Weighted Dose to the Surface Dose In Abdominal CT - Patient Size Dependency

    International Nuclear Information System (INIS)

    Zhou, Y; Scott, A; Allahverdian, J

    2014-01-01

    Purpose: It is possible to measure the patient surface dose non-invasively using radiolucent dosimeters. However, the patient size specific weighted dose remains unknown. We attempted to study the weighted dose to surface dose relationship as the patient size varies in abdominal CT. Methods: Seven abdomen phantoms (CIRS TE series) simulating patients from an infant to a large adult were used. Size specific doses were measured with a 100 mm CT chamber under axial scans using a Siemens Sensation 64 (mCT) and a GE 750 HD. The scanner settings were 120 kVp, 200 mAs with fully opened collimations. Additional kVps (80, 100, 140) were added depending on the phantom sizes. The ratios (r) of the weighted CT dose (Dw) to the surface dose (Ds) were related to the phantom size (L) defined as the diameter resulting the equivalent cross-sectional area. Results: The Dw versus Ds ratio (r) was fitted to a linear relationship: r = 1.083 − 0.007L (R square = 0.995), and r = 1.064 − 0.007L (R square = 0.953), for Siemens Sensation 64 and GE 750 HD, respectively. The relationship appears to be independent of the scanner specifics. Conclusion: The surface dose to the weighted dose ratio decreases linearly as the patient size increases. The result is independent of the scanner specifics. The result can be used to obtain in vivo CT dosimetry in abdominal CT

  6. Dose rate constants for new dose quantities

    International Nuclear Information System (INIS)

    Tschurlovits, M.; Daverda, G.; Leitner, A.

    1992-01-01

    Conceptual changes and new quantities made is necessary to reassess dose rate quantities. Calculations of the dose rate constant were done for air kerma, ambient dose equivalent and directional dose equivalent. The number of radionuclides is more than 200. The threshold energy is selected as 20 keV for the dose equivalent constants. The dose rate constant for the photon equivalent dose as used mainly in German speaking countries as a temporary quantity is also included. (Author)

  7. Dose Prediction for surface nuclear explosions: case studies for Semipalatinsk and Lop Nur tests

    International Nuclear Information System (INIS)

    Takada, Jun

    2008-01-01

    Dose prediction method RAPS after surface nuclear explosion has been developed by using the empirical dose function of USA nuclear test. This method which provides us external total dose, dose rate at any distant, at any time for any yield of nuclear explosion, is useful for radiation protection in case of nuclear events such as terrorism and nuclear war. The validity of RAPS has been confirmed by application to historical surface nuclear test explosions. The first test case study which was done for the first test explosion of the former USSR at the Semipalatinsk Nuclear Test Site on August 29th 1949, shows a good agreement with luminescence dosimetry on a brick. This dose prediction method was applied nuclear tests in Lop Nur. The results indicate dangerous nuclear radiation influences including fatal risk in the wide Uygur area. (author)

  8. Analysis of surface and build up region dose for motorized wedge and omni wedge

    International Nuclear Information System (INIS)

    Panta, Raj Kumar; Sundarum, T.

    2008-01-01

    Megavoltage x-ray beam exhibits the well known phenomenon of dose build-up within the first few millimeters of incident phantom surface or skin. The skin sparing effect of high energy gamma or x-ray photon may be reduced or even lost, if the beam is contaminated with electron or low energy photons. Since skin dose in the treatment of deeply seated tumor may be a limiting factor in the delivery of tumoricidal dose due to possible complications such as erythema, desquamation, fibrosis, necrosis and epilation, the dose distribution in the build up region should be known. The objective of this study was to measure and investigate the surface and build-up region dose for 6 MV and 15 MV photon beam for Motorized wedge and Omni wedge in Precise Digital Linear Accelerator (Elekta)

  9. Interdependence between body surface area and ultraviolet B dose in vitamin D production

    DEFF Research Database (Denmark)

    Bogh, M K B; Schmedes, Anne; Philipsen, P A

    2011-01-01

    Ultraviolet (UV) B radiation increases serum vitamin D level expressed as 25-hydroxyvitamin-D(3) [25(OH)D], but the relationship to body surface area and UVB dose needs investigation.......Ultraviolet (UV) B radiation increases serum vitamin D level expressed as 25-hydroxyvitamin-D(3) [25(OH)D], but the relationship to body surface area and UVB dose needs investigation....

  10. Surface applicators for high dose rate brachytherapy in AIDS-related kaposi's sarcoma

    International Nuclear Information System (INIS)

    Evans, Michael D.C.; Yassa, Mariam; Podgorsak, Ervin B.; Roman, Ted N.; Schreiner, L. John; Souhami, Luis

    1997-01-01

    Purpose: The development of commercially available surface applicators using high dose rate remote afterloading devices has enabled radiotherapy centers to treat selected superficial lesions using a remote afterloading brachytherapy unit. The dosimetric parameters of these applicators, the clinical implementation of this technique, and a review of the initial patient treatment regimes are presented. Methods and Materials: A set of six fixed-diameter (1, 2, and 3 cm), tungsten/steel surface applicators is available for use with a single stepping-source (Ir-192, 370 GBq) high dose rate afterloader. The source can be positioned either in a parallel or perpendicular orientation to the treatment plane at the center of a conical aperture that sits at an SSD of approximately 15 mm and is used with a 1-mm thick removable plastic cap. The surface dose rates, percent depth dose, and off-axis ratios were measured. A custom-built, ceiling-mounted immobilization device secures the applicator on the surface of the patient's lesion during treatment. Results: Between November 1994, and September 1996, 16 AIDS-related Kaposi's sarcoma patients having a total of 120 lesions have been treated with palliative intent. Treatment sites were distributed between the head and neck, extremity, and torso. Doses ranged from 8 to 20 Gy, with a median dose of 10 Gy delivered in a single fraction. Treatments were well tolerated with minimal skin reaction, except for patients with lesions treated to 20 Gy who developed moderate/severe desquamation. Conclusion: Radiotherapy centers equipped with a high dose rate remote afterloading unit may treat small selected surface lesions with commercially available surface applicators. These surface applicators must be used with a protective cap to eliminate electron contamination. The optimal surface dose appears to be either 10 or 15 Gy depending upon the height of the lesion

  11. Depth dose of critical organs of phantom based on surface dose exposed with Dual X-ray absorptiometry: pencil beam using TLD dosimetry

    Directory of Open Access Journals (Sweden)

    Ali Akbar Sharafi

    2009-02-01

    Full Text Available Introduction: Dual X-ray absorptiometry (DXA is one of the most widely used techniques fornon-invasive assessment of bone status. Radiation dosimetry is well established technique for pencilbeam and fan beam DXA system, for the assessment of the surface absorbed dose. No publishedassessment of the absorbed dose for the various depths of the critical organs such as the thyroid anduterus was found. Therefore, in this study, we measured the surface dose and depth dose of criticalorgans to determine the correlation between the depth dose and the surface dose.Materials and Methods: A Lunar DPX-MD (pencil beam system was used in this study. Ananthropomorphic phantom was designed. AP spine and femur scan modes were used to measure thesurface and depth doses of the thyroid left and right lobes and uterus in various deeps and scan centers.TLDs-400 were placed at the surface, near the source and also inserted at different depths in thyroidand uterus of the anthropomorphic phantom. Absorbed doses were measured on the phantom for APspine and femur scans. The correlation between the absorbed dose and the depth was found using thelinear regression analysis.Results: There was no significant correlation between the depth dose and the scan center doseexcept in the femur scan. AP spine effective dose were calculated as 0.064, 0.059, 0.061 and 0.242μSv for thyroid left, right lobes, uterus and ovary, respectively.Conclusion: It is concluded that there is significant correlation between the surface and the doseof various depths of the scanned sections.

  12. A consideration on internal dose evaluation and intervention based on a surface contamination concept

    International Nuclear Information System (INIS)

    Yasuda, H.

    1997-01-01

    Long-term radiation doses received by the inhabitants after the Chernobyl accident have been evaluated according to the surface contamination levels on the ground surface. The health effects have also been discussed by comparison between the surface-contaminated area and the uncontaminated control area. Selected protective measures were carried out in accordance with the contamination level of surface soil. These have been based on the 'surface contamination concept' which assumes that the radiation risk to inhabitants is proportional to the level of ground-surface contamination. The observations collected in regions around Chernobyl, however, show that the internal radiation doses to the inhabitants poorly correlate with the surface contamination level. This fact poses a question on the suitability of dose evaluations and interventions based on this concept

  13. The contribution to surface dose form air scatter in mega voltage photon beams

    International Nuclear Information System (INIS)

    Carolan, M.G.; Butson, M.; Metcalfe, P.

    1996-01-01

    Full text: The minimisation of surface dose is an important requirement in radiotherapy in order to avoid undesirable skin reactions. For this reason significant effort has been expended to avoid and understand photon and electron scatter in the heads of linear accelerators which may contribute to surface dose. In this study we have examined the contribution to surface dose which arises due to scatter in the air above the patient. Experimental investigations of air contributions are difficult to design and execute. Therefore we have used Monte Carlo calculations to determine the effect that the presence of air has on surface dose. Methods: The Los Alamos Monte Carlo Neutron and Photon transport code, MCNP4A which incorporates the ETRAN electron transport code from the Integrated TIGER Series of codes was used for our simulations. The geometry used in the model was a 30 cm cube of water. The dose was tallied in cylindrical elements of 7 cm diameter along the axis of the photon beam. For the first millimetre along the beam axis in the phantom, the dose was determined at 0.1 mm increments in 0.1 mm thick volumes. For depths between 1.0 mm and 15.0 mm the dose was determined every 1 mm in 1 mm cylindrical volumes. This yields a depth dose profile with fine spatial resolution near the phantom surface. Dose was also tallied at depths of 5.0, 10.0, 15.0 and 20.0 cm. The simulations were done assuming a 6 MV photon source with a diameter of 1.5 cm, a gaussian intensity profile and a photon energy spectrum based on Mohan et al. (Med. Phys. 12 (1985) 592). No accelerator head geometry was modelled. The field size was defined by virtual collimators which were simply thin regions of zero photon importance and therefore do not contribute to photon or electron scatter. All simulations were run for sufficient particle histories (∼2x10 7 - 5x10 7 source photons) to give statistical uncertainties of ≤ 10% and in most cases ≤ 5%. Fields of size 10, 15, 20 and 25 cm were used

  14. ANALYSIS OF RESPIRATORY DEPOSITION OF INHALED PARTICLES FOR DIFFERENT DOSE METRICS: COMPARISON OF NUMBER, SURFACE AREA AND MASS DOSE OF TYPICAL AMBIENT BI-MODAL AEROSOLS

    Science.gov (United States)

    ANALYSIS OF RESPIRATORY DEPOSITION OF INHALED PARTICLES FOR DIFFERENT DOSE METRICS: COMPARISON OF NUMBER, SURFACE AREA AND MASS DOSE OF TYPICAL AMBIENT BI-MODAL AEROSOLS.Chong S. Kim, SC. Hu*, PA Jaques*, US EPA, National Health and Environmental Effects Research Laboratory, ...

  15. MLSOIL and DFSOIL - computer codes to estimate effective ground surface concentrations for dose computations

    International Nuclear Information System (INIS)

    Sjoreen, A.L.; Kocher, D.C.; Killough, G.G.; Miller, C.W.

    1984-11-01

    This report is a user's manual for MLSOIL (Multiple Layer SOIL model) and DFSOIL (Dose Factors for MLSOIL) and a documentation of the computational methods used in those two computer codes. MLSOIL calculates an effective ground surface concentration to be used in computations of external doses. This effective ground surface concentration is equal to (the computed dose in air from the concentration in the soil layers)/(the dose factor for computing dose in air from a plane). MLSOIL implements a five compartment linear-transfer model to calculate the concentrations of radionuclides in the soil following deposition on the ground surface from the atmosphere. The model considers leaching through the soil as well as radioactive decay and buildup. The element-specific transfer coefficients used in this model are a function of the k/sub d/ and environmental parameters. DFSOIL calculates the dose in air per unit concentration at 1 m above the ground from each of the five soil layers used in MLSOIL and the dose per unit concentration from an infinite plane source. MLSOIL and DFSOIL have been written to be part of the Computerized Radiological Risk Investigation System (CRRIS) which is designed for assessments of the health effects of airborne releases of radionuclides. 31 references, 3 figures, 4 tables

  16. Paediatric dose display

    International Nuclear Information System (INIS)

    Griffin, D.W.; Derges, S.; Hesslewood, S.

    1984-01-01

    A compact, inexpensive unit, based on an 8085 microprocessor, has been designed for calculating doses of intravenous radioactive injections for children. It has been used successfully for over a year. The dose is calculated from the body surface area and the result displayed in MBq. The operator can obtain the required dose on a twelve character alphanumeric display by entering the age of the patient and the adult dose using a hexadecimal keyboard. Circuit description, memory map and input/output, and firmware are dealt with. (U.K.)

  17. Enjebi Island dose assessment

    International Nuclear Information System (INIS)

    Robison, W.L.; Conrado, C.L.; Phillips, W.A.

    1987-07-01

    We have updeated the radiological dose assessment for Enjebi Island at Enewetak Atoll using data derived from analysis of food crops grown on Enjebi. This is a much more precise assessment of potential doses to people resettling Enjebi Island than the 1980 assessment in which there were no data available from food crops on Enjebi. Details of the methods and data used to evaluate each exposure pathway are presented. The terrestrial food chain is the most significant potential exposure pathway and 137 Cs is the radionuclide responsible for most of the estimated dose over the next 50 y. The doses are calculated assuming a resettlement date of 1990. The average wholebody maximum annual estimated dose equivalent derived using our diet model is 166 mremy;the effective dose equivalent is 169 mremy. The estimated 30-, 50-, and 70-y integral whole-body dose equivalents are 3.5 rem, 5.1 rem, and 6.2 rem, respectively. Bone-marrow dose equivalents are only slightly higher than the whole-body estimates in each case. The bone-surface cells (endosteal cells) receive the highest dose, but they are a less sensitive cell population and are less sensitive to fatal cancer induction than whole body and bone marrow. The effective dose equivalents for 30, 50, and 70 y are 3.6 rem, 5.3 rem, and 6.6 rem, respectively. 79 refs., 17 figs., 24 tabs

  18. Construction of boundary-surface-based Chinese female astronaut computational phantom and proton dose estimation

    International Nuclear Information System (INIS)

    Sun Wenjuan; Xie Tianwu; Liu Qian; Jia Xianghong; Xu Feng

    2013-01-01

    With the rapid development of China's space industry, the importance of radiation protection is increasingly prominent. To provide relevant dose data, we first developed the Visible Chinese Human adult Female (VCH-F) phantom, and performed further modifications to generate the VCH-F Astronaut (VCH-FA) phantom, incorporating statistical body characteristics data from the first batch of Chinese female astronauts as well as reference organ mass data from the International Commission on Radiological Protection (ICRP; both within 1% relative error). Based on cryosection images, the original phantom was constructed via Non-Uniform Rational B-Spline (NURBS) boundary surfaces to strengthen the deformability for fitting the body parameters of Chinese female astronauts. The VCH-FA phantom was voxelized at a resolution of 2 x 2 x 4 mm 3 for radioactive particle transport simulations from isotropic protons with energies of 5000 - 10 000 MeV in Monte Carlo N-Particle eXtended (MCNPX) code. To investigate discrepancies caused by anatomical variations and other factors, the obtained doses were compared with corresponding values from other phantoms and sex-averaged doses. Dose differences were observed among phantom calculation results, especially for effective dose with low-energy protons. Local skin thickness shifts the breast dose curve toward high energy, but has little impact on inner organs. Under a shielding layer, organ dose reduction is greater for skin than for other organs. The calculated skin dose per day closely approximates measurement data obtained in low-Earth orbit (LEO). (author)

  19. Surface dose of X rays to patients during extracorporeal shock wave lithotripsy

    International Nuclear Information System (INIS)

    Jiang Qingqi; Weng Zhigeng; Feng Ming; Wang Guomin.

    1990-01-01

    During extracorporeal shock wave lithotripsy (ESWL), the fluoroscopy must be made to show the location and size of the stone thus the patient has to be exposed to X rays. The surface dose to patients during ESWL was measured in an investigation on 134 cases of renal lithiasis admitted in a certain hospital of Shanghai. The results show that the average skin dose equivalent for these patients was 162 mSv and the magnitude of doses was depended upon some factors such as the size and location of the stone

  20. SU-F-T-93: Breast Surface Dose Enhancement Using a Clinical Prone Breast Board

    International Nuclear Information System (INIS)

    Guerra, M; Jozsef, G

    2016-01-01

    Purpose: The use of specialized patient set-up devices in radiotherapy, such as prone breast boards, may have unwanted dosimetric effects. The goal of this study was to evaluate the effect of a clinically used prone breast board on skin dose due to buildup. Methods: GafChromic film (EBT3) was used for dose measurements on the surface of a solid water phantom shaped to mimic the curvature of the breast. We investigated two setup scenarios: the medial field border placed at the medial edge of the board and 1 cm contralaterally from that edge. A strip of film was taped to the medial surface of the phantom. Gantry angles varied from 10 to 30 degrees below the lateral gantry position, representing anterior oblique fields. The measurements were performed with and without the presence of the board; the ratio of their corresponding doses (dose enhancement) was evaluated. Results: For the cases where the field edge is at the edge of the board, the dose enhancement is negligible for all the tested angles. When the field edge is 1 cm inside the board, the maximum surface dose enhancement varies depending on the gantry angle between 2.2 for 30 degrees and 3.2 for 20 degrees. The length on the film at which the presence of the board is detectable (i.e. where there is dose enhancement) is longer for the shallower angles. Conclusion: Even the low-density, thin carbon fiber board with a thin soft foam pad on the top can produce significant dose enhancement on the skin in prone breast treatment due to loss of buildup. However, it happens only when the patient mid-sternum is over the board, i.e. the medial edge of the field traverses through the board and pad. Even then, the effect occurs only at the field edge, i.e. the penumbral region.

  1. Technical Note: Out-of-field dose measurement at near surface with plastic scintillator detector.

    Science.gov (United States)

    Bourgouin, Alexandra; Varfalvy, Nicolas; Archambault, Louis

    2016-09-08

    Out-of-field dose depends on multiple factors, making peripheral dosimetry com-plex. Only a few dosimeters have the required features for measuring peripheral dose. Plastic scintillator dosimeters (PSDs) offer numerous dosimetric advantages as required for out-of-field dosimetry. The purpose of this study is to determine the potential of using PSD as a surface peripheral dosimeter. Measurements were performed with a parallel-plate ion chamber, a small volume ion chamber, and with a PSD. Lateral-dose measurements (LDM) at 0.5 cm depth and depth-dose curve (PDD) were made and compared to the dose calculation provided by a treatment planning system (TPS). This study shows that a PSD can measure a dose as low as 0.51 ± 0.17 cGy for photon beam and 0.58 ± 0.20 cGy for electron beam with a difference of 0.2 and 0.1 cGy compared to a parallel-plate ion chamber. This study demonstrates the potential of using PSD as an out-of-field dosimeter since measure-ments with PSD avoid averaging over a too-large depth, at 1 mm diameter, and can make precise measurement at very low dose. Also, electronic equilibrium is easier to reach with PSD due to its small sensitive volume and its water equivalence. © 2016 The Authors.

  2. The need for national diagnostic reference levels: entrance surface dose measurement in intraoral radiography

    International Nuclear Information System (INIS)

    Mortazavi, S. M. J.; Shareghi, A.; Kavousi, A.; Ghiassi-Nejad, M.; Jafari-Zadeh, M.; Nazeri, F.; Mozdarani, H.

    2004-01-01

    Background: Intraoral radiographies are the most frequent X-ray examinations in humans. According to International Commission on Radiation Protection recommendations, the selection of a diagnostic reference level should be specific to a country or region. Critical organs such as thyroid gland are exposed to X-rays in intraoral radiography and these exposures should be kept as low as reasonably achievable. To assist the development of DRLs for intraoral radiography, a National Radiation Protection Department-sponsored pilot study was carried out. Materials and methods: thermoluminescent dosimetry is widely acknowledged to be the recommended method for measuring entrance surface doses. In this study, entrance surface doses was measured using LiF thermoluminescent dosimeters on the skin (either mandibular or maxillary arcs) of 40 patients. Three thermoluminescent dosimetry chips were placed on the skin of each patient. The doses were averaged for each radiography and mean entrance surface doses of all patients calculated. Results: the mean ±SD entrance surface dose at the center of the beam on the patient's skin in intraoral radiography was 1.173 ±0.606 mGy (ranged from 0.01 o 0.40 m Gy). The mean entrance surface doses for male and female patients were 1.380± 0.823, and 1.004± 0.258 respectively. No statistically significant difference was found between these means. Despite its necessity , in national level , there is no published data on the diagnostic reference levels for intraoral radiography. However, the results obtained in this study are lower than those reported by investigators in other countries. Conclusion: in IR Iran , due to lack of large scale studies, no diagnostic reference levels have been set for X-ray diagnostic procedures. Due to lack of national diagnostic reference levels, it is not possible to clarify whether in intraoral radiographies any dose reduction techniques are needed. We intend to perform similar nationwide studies to set the

  3. Dosimetric perturbations of a lead shield for surface and interstitial high-dose-rate brachytherapy

    International Nuclear Information System (INIS)

    Candela-Juan, Cristian; Granero, Domingo; Vijande, Javier; Ballester, Facundo; Perez-Calatayud, Jose; Rivard, Mark J

    2014-01-01

    In surface and interstitial high-dose-rate brachytherapy with either 60 Co, 192 Ir, or 169 Yb sources, some radiosensitive organs near the surface may be exposed to high absorbed doses. This may be reduced by covering the implants with a lead shield on the body surface, which results in dosimetric perturbations. Monte Carlo simulations in Geant4 were performed for the three radionuclides placed at a single dwell position. Four different shield thicknesses (0, 3, 6, and 10 mm) and three different source depths (0, 5, and 10 mm) in water were considered, with the lead shield placed at the phantom surface. Backscatter dose enhancement and transmission data were obtained for the lead shields. Results were corrected to account for a realistic clinical case with multiple dwell positions. The range of the high backscatter dose enhancement in water is 3 mm for 60 Co and 1 mm for both 192 Ir and 169 Yb. Transmission data for 60 Co and 192 Ir are smaller than those reported by Papagiannis et al (2008 Med. Phys. 35 4898–4906) for brachytherapy facility shielding; for 169 Yb, the difference is negligible. In conclusion, the backscatter overdose produced by the lead shield can be avoided by just adding a few millimetres of bolus. Transmission data provided in this work as a function of lead thickness can be used to estimate healthy organ equivalent dose saving. Use of a lead shield is justified. (paper)

  4. Increased dose near the skin due to electromagnetic surface beacon transponder.

    Science.gov (United States)

    Ahn, Kang-Hyun; Manger, Ryan; Halpern, Howard J; Aydogan, Bulent

    2015-05-08

    The purpose of this study was to evaluate the increased dose near the skin from an electromagnetic surface beacon transponder, which is used for localization and tracking organ motion. The bolus effect due to the copper coil surface beacon was evaluated with radiographic film measurements and Monte Carlo simulations. Various beam incidence angles were evaluated for both 6 MV and 18 MV experimentally. We performed simulations using a general-purpose Monte Carlo code MCNPX (Monte Carlo N-Particle) to supplement the experimental data. We modeled the surface beacon geometry using the actual mass of the glass vial and copper coil placed in its L-shaped polyethylene terephthalate tubing casing. Film dosimetry measured factors of 2.2 and 3.0 enhancement in the surface dose for normally incident 6 MV and 18 MV beams, respectively. Although surface dose further increased with incidence angle, the relative contribution from the bolus effect was reduced at the oblique incidence. The enhancement factors were 1.5 and 1.8 for 6 MV and 18 MV, respectively, at an incidence angle of 60°. Monte Carlo simulation confirmed the experimental results and indicated that the epidermal skin dose can reach approximately 50% of the dose at dmax at normal incidence. The overall effect could be acceptable considering the skin dose enhancement is confined to a small area (~ 1 cm2), and can be further reduced by using an opposite beam technique. Further clinical studies are justified in order to study the dosimetric benefit versus possible cosmetic effects of the surface beacon. One such clinical situation would be intact breast radiation therapy, especially large-breasted women.

  5. Evaluation of surface dose rate on C-14 scrubber and gas bag

    International Nuclear Information System (INIS)

    Gang, D. W.; Lee, H. S.; Lee, D. H.

    2003-01-01

    In CANDU(Canadian Deuterium Uranium) reactors, purge and discharge of moderator cover gas has been performed via vapor recovery system. The methods employed in C-14 removal are mainly based on reactions of CO 2 with absorber of adsorbent. In order to choose an optimum process, we should consider the characteristics of the process, such as, temperature, pressure, humidity etc. and surface dose rate on C-14 scrubber and gas bag to estimate job-related personnel doses. Assuming that the whole C-14 scrubber was completely replaced after one-cycle operation, and that its C-14 activity for one-cycle operation was 40 mCi, we calculated the surface dose rate at the six points of the C-14 scrubber. This calculation showed that the dose rate on the surface of cartridge was only 1.25μSυ/hγ because of low energy of β ray. It is concluded, therefore, that the cartridge change-out is safe because the operation of C-14 removal system causes only a small increase in dose rate

  6. Construction of boundary-surface-based Chinese female astronaut computational phantom and proton dose estimation

    Science.gov (United States)

    Sun, Wenjuan; JIA, Xianghong; XIE, Tianwu; XU, Feng; LIU, Qian

    2013-01-01

    With the rapid development of China's space industry, the importance of radiation protection is increasingly prominent. To provide relevant dose data, we first developed the Visible Chinese Human adult Female (VCH-F) phantom, and performed further modifications to generate the VCH-F Astronaut (VCH-FA) phantom, incorporating statistical body characteristics data from the first batch of Chinese female astronauts as well as reference organ mass data from the International Commission on Radiological Protection (ICRP; both within 1% relative error). Based on cryosection images, the original phantom was constructed via Non-Uniform Rational B-Spline (NURBS) boundary surfaces to strengthen the deformability for fitting the body parameters of Chinese female astronauts. The VCH-FA phantom was voxelized at a resolution of 2 × 2 × 4 mm3for radioactive particle transport simulations from isotropic protons with energies of 5000–10 000 MeV in Monte Carlo N-Particle eXtended (MCNPX) code. To investigate discrepancies caused by anatomical variations and other factors, the obtained doses were compared with corresponding values from other phantoms and sex-averaged doses. Dose differences were observed among phantom calculation results, especially for effective dose with low-energy protons. Local skin thickness shifts the breast dose curve toward high energy, but has little impact on inner organs. Under a shielding layer, organ dose reduction is greater for skin than for other organs. The calculated skin dose per day closely approximates measurement data obtained in low-Earth orbit (LEO). PMID:23135158

  7. Calculated dose factors for the radiosensitive tissues in bone irradiated by surface-deposited radionuclides

    International Nuclear Information System (INIS)

    Spiers, F.W.; Whitwell, J.R.; Beddoe, A.H.

    1978-01-01

    The method of calculating dose factors for the haemopoietic marrow and endosteal tissues in human trabecular bone, used by Whitwell and Spiers for volume-seeking radionuclides, has been developed for the case of radionuclides which are deposited as very thin layers on bone surfaces. The Monte Carlo method is again used, but modifications to the computer program are made to allow for a surface rather than a volume source of particle emission. The principal change is the introduction of a surface-orientation factor which is shown to have a value of approximately 2, varying slightly with bone structure. Results are given for β-emitting radionuclides ranging from 171 Tm(anti Esub(β) = 0.025 MeV) to 90 Y(anti Esub(β) = 0.93 MeV), and also for the α-emitter 239 Pu. It is shown that where the particle ranges are short compared with the dimensions of the bone structures the dose factors for the surface seekers are much greater than those for the volume seekers. For long range particles the dose factors for surface- and volume-seeking radionuclides converge. Comparisons are given relating the dose factors calculated in this paper on the basis of measured bone structures to those of other workers based on single plane geometry. (author)

  8. SU-E-J-198: Out-Of-Field Dose and Surface Dose Measurements of MRI-Guided Cobalt-60 Radiotherapy

    International Nuclear Information System (INIS)

    Lamb, J; Agazaryan, N; Cao, M; Low, D; Thomas, D; Yang, Y

    2015-01-01

    Purpose: To measure quantities of dosimetric interest in an MRI-guided cobalt radiotherapy machine that was recently introduced to clinical use. Methods: Out-of-field dose due to photon scatter and leakage was measured using an ion chamber and solid water slabs mimicking a human body. Surface dose was measured by irradiating stacks of radiochromic film and extrapolating to zero thickness. Electron out-of-field dose was characterized using solid water slabs and radiochromic film. Results: For some phantom geometries, up to 50% of Dmax was observed up to 10 cm laterally from the edge of the beam. The maximum penetration was between 1 and 2 mm in solid water, indicating an electron energy not greater than approximately 0.4 MeV. Out-of-field dose from photon scatter measured at 1 cm depth in solid water was found to fall to less than 10% of Dmax at a distance of 1.2 cm from the edge of a 10.5 × 10.5 cm field, and less that 1% of Dmax at a distance of 10 cm from field edge. Surface dose was measured to be 8% of Dmax. Conclusion: Surface dose and out-of-field dose from the MRIguided cobalt radiotherapy machine was measured and found to be within acceptable limits. Electron out-of-field dose, an effect unique to MRI-guided radiotherapy and presumed to arise from low-energy electrons trapped by the Lorentz force, was quantified. Dr. Low is a member of the scientific advisory board of ViewRay, Inc

  9. Surface membrane based bladder registration for evaluation of accumulated dose during brachytherapy in cervical cancer

    DEFF Research Database (Denmark)

    Noe, Karsten Østergaard; Tanderup, Kari; Sørensen, Thomas Sangild

    2011-01-01

    of the fixed surface. Optional landmark based matches can be included in the suggested iterative solver. The technique is demonstrated for bladder registration in brachytherapy treatment evaluation of cervical cancer. It holds promise to better estimate the accumulated but unintentional dose delivered...

  10. Surface damage of 316 stainless steel irradiated with 4He+ to high doses

    International Nuclear Information System (INIS)

    Kaminsky, M.; Das, S.K.

    1978-01-01

    Surface blistering of niobium by implantation with helium ions in the 9 to 15 keV range was investigated. The apparent disappearance of blisters at sufficiently high doses was believed to be an equilibrium effect. To determine whether high temperature annealing causes the equilibrium condition, stainless steel-316 samples were irradiated at a constant 450 0 C. Results are presented

  11. Calculation of rectal dose surface histograms in the presence of time varying deformations

    International Nuclear Information System (INIS)

    Roeske, John C.; Spelbring, Danny R.; Vijayakumar, S.; Forman, Jeffrey D.; Chen, George T.Y.

    1996-01-01

    Purpose: Dose volume (DVH) and dose surface histograms (DSH) of the bladder and rectum are usually calculated from a single treatment planning scan. These DVHs and DSHs will eventually be correlated with complications to determine parameters for normal tissue complication probabilities (NTCP). However, from day to day, the size and shape of the rectum and bladder may vary. The purpose of this study is to compare a more accurate estimate of the time integrated DVHs and DSHs of the rectum (in the presence of daily variations in rectal shape) to initial DVHs/DSHs. Methods: 10 patients were scanned once per week during the course of fractionated radiotherapy, typically accumulating a total of six scans. The rectum and bladder were contoured on each of the studies. The model used to assess effects of rectal contour deformation is as follows: the contour on a given axial slice (see figure) is boxed within a rectangle. A line drawn parallel to the AP axis through the rectangle equally partitions the box. Starting at the intersection of the vertical line and the rectal contour, points on the contour are marked off representing the same rectal dose point, even in the presence of distortion. Corresponding numbered points are used to sample the dose matrix and create a composite DSH. The model assumes uniform stretching of the rectal contour for any given axial cut, and no twist of the structure or vertical displacement. A similar model is developed for the bladder with spherical symmetry. Results: Normalized DSHs (nDSH) for each CT scan were calculated as well as the time averaged nDSH over all scans. These were compared with the nDSH from the initial planning scan. Individual nDSHs differed by 8% surface area irradiated at the 80% dose level, to as much as 20% surface area in the 70-100% dose range. DSH variations are due to position and shape changes in the rectum during different CT scans. The spatial distribution of dose is highly variable, and depends on the field

  12. Impact of thermoplastic mask on X-ray surface dose calculated with Monte Carlo code

    International Nuclear Information System (INIS)

    Zhao Yanqun; Li Jie; Wu Liping; Wang Pei; Lang Jinyi; Wu Dake; Xiao Mingyong

    2010-01-01

    Objective: To calculate the effects of thermoplastic mask on X-ray surface dose. Methods: The BEAMnrc Monte Carlo Code system, designed especially for computer simulation of radioactive sources, was performed to evaluate the effects of thermoplastic mask on X-ray surface dose.Thermoplastic mask came from our center with a material density of 1.12 g/cm 2 . The masks without holes, with holes size of 0.1 cm x 0.1 cm, and with holes size of 0. 1 cm x 0.2 cm, and masks with different depth (0.12 cm and 0.24 cm) were evaluated separately. For those with holes, the material width between adjacent holes was 0.1 cm. Virtual masks with a material density of 1.38 g/cm 3 without holes with two different depths were also evaluated. Results: Thermoplastic mask affected X-rays surface dose. When using a thermoplastic mask with the depth of 0.24 cm without holes, the surface dose was 74. 9% and 57.0% for those with the density of 1.38 g/cm 3 and 1.12 g/cm 3 respectively. When focusing on the masks with the density of 1.12 g/cm 3 , the surface dose was 41.2% for those with 0.12 cm depth without holes; 57.0% for those with 0. 24 cm depth without holes; 44.5% for those with 0.24 cm depth with holes size of 0.1 cm x 0.2 cm;and 54.1% for those with 0.24 cm depths with holes size of 0.1 cm x 0.1 cm.Conclusions: Using thermoplastic mask during the radiation increases patient surface dose. The severity is relative to the hole size and the depth of thermoplastic mask. The surface dose change should be considered in radiation planning to avoid severe skin reaction. (authors)

  13. SUDOQU, a new dose-assessment methodology for radiological surface contamination.

    Science.gov (United States)

    van Dillen, Teun; van Dijk, Arjan

    2018-06-12

    A new methodology has been developed for the assessment of the annual effective dose resulting from removable and fixed radiological surface contamination. It is entitled SUDOQU (SUrface DOse QUantification) and it can for instance be used to derive criteria for surface contamination related to the import of non-food consumer goods, containers and conveyances, e.g., limiting values and operational screening levels. SUDOQU imposes mass (activity)-balance equations based on radioactive decay, removal and deposition processes in indoor and outdoor environments. This leads to time-dependent contamination levels that may be of particular importance in exposure scenarios dealing with one or a few contaminated items only (usually public exposure scenarios, therefore referred to as the 'consumer' model). Exposure scenarios with a continuous flow of freshly contaminated goods also fall within the scope of the methodology (typically occupational exposure scenarios, thus referred to as the 'worker model'). In this paper we describe SUDOQU, its applications, and its current limitations. First, we delineate the contamination issue, present the assumptions and explain the concepts. We describe the relevant removal, transfer, and deposition processes, and derive equations for the time evolution of the radiological surface-, air- and skin-contamination levels. These are then input for the subsequent evaluation of the annual effective dose with possible contributions from external gamma radiation, inhalation, secondary ingestion (indirect, from hand to mouth), skin contamination, direct ingestion and skin-contact exposure. The limiting effective surface dose is introduced for issues involving the conservatism of dose calculations. SUDOQU can be used by radiation-protection scientists/experts and policy makers in the field of e.g. emergency preparedness, trade and transport, exemption and clearance, waste management, and nuclear facilities. Several practical examples are worked

  14. Oxygen dosing the surface of SrTiO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Dudy, L.; Scheiderer, P.; Schuetz, P.; Gabel, J.; Buchwald, M.; Sing, M.; Claessen, R. [Physikalisches Institut, Universitaet Wuerzburg (Germany); Denlinger, J.D. [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA, 94270 (United States); Schlueter, C.; Lee, T.L. [Diamond Light Source Ltd., Didcot, Oxfordshire (United Kingdom)

    2015-07-01

    The highly mobile two-dimensional electron system (2DES) on the surface of the insulating SrTiO{sub 3}(STO) offers exciting perspectives for advanced material design. This 2DES resides in a depletion layer caused by oxygen deficiency of the surface. With photoemission spectroscopy, we monitor the appearance of quasi-particle weight (QP) at the Fermi energy and oxygen vacancy induced states in the band gap (IG). Both, QP and IG weight, increase and decrease respectively upon exposure to extreme ultraviolet (XUV) light and in-situ oxygen dosing. By a proper adjustment of oxygen dosing, any intermediate state can be stabilized providing full control over the charge carrier density. From a comparison of the charge carrier concentrations obtained from an analysis of core-level spectra and the Fermi-surface volume, we conclude on a spatially inhomogeneous surface electronic structure with at least two different phases.

  15. Surface dose investigation of the flattening filter-free photon beams.

    Science.gov (United States)

    Wang, Yuenan; Khan, Mohammad K; Ting, Joseph Y; Easterling, Stephen B

    2012-06-01

    Flattening filter-free (FFF) x-rays can provide more efficient use of photons and a significant increase of dose rate compared with conventional flattened x-rays, features that are especially beneficial for stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT). The available data on the entrance doses of the FFF photon beams remain limited. The purpose of this study was to investigate the entrance dose of FFF photons in the buildup region and to compare it with that of conventional flattened photons. A Varian TrueBeam linear accelerator has been in full clinical operation with 6-MV and 10-MV FFF and flattened x-ray photons. Entrance dose at the surface was measured using a parallel plate ionization chamber in a solid water phantom with buildup depth = 0~15 mm for 6X and 0~25 mm for 10X. Different field size (FS) patterns were created in the Eclipse Treatment Planning System by multileaf collimator (MLC) rather than jaws (FS = 2 × 2, 3 × 3, 4 × 4, 6 × 6, and 10 × 10 cm(2) by MLC and jaw size = 2.2 × 2.2, 3.2 × 3.2, 4.2 × 4.2, 6 × 6, and 10 × 10 cm(2)). The smallest FS was about four times larger than the ion chamber dimension. All buildup dose measurements were normalized to FS = 10 × 10 cm(2) at the depth of dose maximum (dmax). Good repeatability was demonstrated and surface dose increased linearly with FS for both flattened and FFF photons. The entrance dose of the FFF photons was modestly larger than that of the corresponding flattened photons for both 6X and 10X for different FS ranging from 2 × 2 cm(2) to 10 × 10 cm(2). The FFF photons have a higher entrance dose than that of the corresponding flattened photons for FS smaller than 10 × 10 cm(2). However, the difference is not substantial and may be clinically insignificant. Published by Elsevier Inc.

  16. Dose in conventional radiography

    International Nuclear Information System (INIS)

    Acuna D, E.; Padilla R, Z. P.; Escareno J, E.; Vega C, H. R.

    2011-10-01

    It has been pointed out that medical exposures are the most significant sources of exposure to ionizing radiation for the general population. Inside the medical exposures the most important is the X-ray use for diagnosis, which is by far the largest contribution to the average dose received by the population. From all studies performed in radiology the chest radiography is the most abundant. In an X-ray machine, voltage and current are combined to obtain a good image and a reduce dose, however due to the workload in a radiology service individual dose is not monitored. In order to evaluate the dose due to chest radiography in this work a plate phantom was built according to the ISO recommendations using methylmethacrylate walls and water. The phantom was used in the Imaging department of the Zacatecas General Hospital as a radiology patient asking for a chest study; using thermoluminescent dosimeters, TLD 100 the kerma at the surface entrance was determined. (Author)

  17. Dose gradient curve: A new tool for evaluating dose gradient.

    Science.gov (United States)

    Sung, KiHoon; Choi, Young Eun

    2018-01-01

    Stereotactic radiotherapy, which delivers an ablative high radiation dose to a target volume for maximum local tumor control, requires a rapid dose fall-off outside the target volume to prevent extensive damage to nearby normal tissue. Currently, there is no tool to comprehensively evaluate the dose gradient near the target volume. We propose the dose gradient curve (DGC) as a new tool to evaluate the quality of a treatment plan with respect to the dose fall-off characteristics. The average distance between two isodose surfaces was represented by the dose gradient index (DGI) estimated by a simple equation using the volume and surface area of isodose levels. The surface area was calculated by mesh generation and surface triangulation. The DGC was defined as a plot of the DGI of each dose interval as a function of the dose. Two types of DGCs, differential and cumulative, were generated. The performance of the DGC was evaluated using stereotactic radiosurgery plans for virtual targets. Over the range of dose distributions, the dose gradient of each dose interval was well-characterized by the DGC in an easily understandable graph format. Significant changes in the DGC were observed reflecting the differences in planning situations and various prescription doses. The DGC is a rational method for visualizing the dose gradient as the average distance between two isodose surfaces; the shorter the distance, the steeper the dose gradient. By combining the DGC with the dose-volume histogram (DVH) in a single plot, the DGC can be utilized to evaluate not only the dose gradient but also the target coverage in routine clinical practice.

  18. From personnel dose to personal dose

    International Nuclear Information System (INIS)

    Hoefert, M.; Raffnsoe, R.C.; Tuyn, J.W.N.; Wittekind, D.

    1985-01-01

    From following the development of personnel doses at CERN over the past six years it has become evident that work in areas of induced radioactivity is the principal cause of exposure. The results of photon dose measurements free-in-air and around a phantom are presented and discussed in the light of new quantities in individual monitoring. The importance of these results, with respect to the practical situation, is discussed and the problem of phantom size is mentioned. Finally, the results of dose measurements in the phantom are presented, since such information is important in cases where it becomes necessary to transform personnel doses into personal doses. (author)

  19. Individual fluorouracil dose adjustment in FOLFOX based on pharmacokinetic follow-up compared with conventional body-area-surface dosing: a phase II, proof-of-concept study.

    Science.gov (United States)

    Capitain, Olivier; Asevoaia, Andreaa; Boisdron-Celle, Michele; Poirier, Anne-Lise; Morel, Alain; Gamelin, Erick

    2012-12-01

    To compare the efficacy and safety of pharmacokinetically (PK) guided fluorouracil (5-FU) dose adjustment vs. standard body-surface-area (BSA) dosing in a FOLFOX (folinic acid, fluorouracil, oxaliplatin) regimen in metastatic colorectal cancer (mCRC). A total of 118 patients with mCRC were administered individually determined PK-adjusted 5-FU in first-line FOLFOX chemotherapy. The comparison arm consisted of 39 patients, and these patients were also treated with FOLFOX with 5-FU by BSA. For the PK-adjusted arm 5-FU was monitored during infusion, and the dose for the next cycle was based on a dose-adjustment chart to achieve a therapeutic area under curve range (5-FU(ODPM Protocol)). The objective response rate was 69.7% in the PK-adjusted arm, and median overall survival and median progression-free survival were 28 and 16 months, respectively. In the traditional patients who received BSA dosage, objective response rate was 46%, and overall survival and progression-free survival were 22 and 10 months, respectively. Grade 3/4 toxicity was 1.7% for diarrhea, 0.8% for mucositis, and 18% for neutropenia in the dose-monitored group; they were 12%, 15%, and 25%, respectively, in the BSA group. Efficacy and tolerability of PK-adjusted FOLFOX dosing was much higher than traditional BSA dosing in agreement with previous reports for 5-FU monotherapy PK-adjusted dosing. Analysis of these results suggests that PK-guided 5-FU therapy offers added value to combination therapy for mCRC. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Absolute and relative dose-surface and dose-volume histograms of the bladder: which one is the most representative for the actual treatment?

    International Nuclear Information System (INIS)

    Hoogeman, Mischa S; Peeters, Stephanie T H; Bois, Josien de; Lebesque, Joos V

    2005-01-01

    The purpose of this study was to quantify to what extent relative and absolute bladder dose-volume and dose-surface histograms of the planning CT scan were representative for the actual treatment. We used data of 17 patients, who each received 11 repeat CT scans and a planning CT scan. The repeat CT scans were matched on the planning CT scan by the bony anatomy. Clinical treatment plans were used to evaluate the impact of bladder filling changes on the four histogram types. The impact was quantified by calculating for this patient group the correlation coefficient between the planning histogram and the treatment histogram. We found that the absolute dose-surface histogram was the most representative one for the actual treatment

  1. SSD effects on high energy x-ray surface and build up dose

    International Nuclear Information System (INIS)

    Cheung, T.; Yu, P.K.N.; Butson, M.J.; Cancer Services, Wollongong, NSW

    2004-01-01

    Full text: Dose in the build up region for high energy x-rays produced by a medical linear accelerator is affected by the x-ray source to patient surface distance (SSD). The use of isocentric treatments whereby the tumour is positions 100cm from the source means that depending of the depth of the tumour and the size of the patient, the SSD can vary from distances of 80cm to 100cm. To achieve larger field sizes, the SSD can also be extended out to 120cm at times. Results have shown that open fields are not significantly affected by SSD changes with deviations in percentage dose being less than 4% of maximum dose for SSD's from 80cm to 120cm SSD. With the introduction of beam modifying devices such as Perspex blocking trays, the effects are significant with a deviation of up to 22% measured at 6MV energy with a 6mm Perspex tray for SSD's from 80cm to 120cm. These variations are largest at the skin surface and reduce with depth. The use of a multi leaf collimator for blocking removes extra skin dose caused by the Perspex block trays with decreasing SSD. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  2. Dose sculpting with generalized equivalent uniform dose

    International Nuclear Information System (INIS)

    Wu Qiuwen; Djajaputra, David; Liu, Helen H.; Dong Lei; Mohan, Radhe; Wu, Yan

    2005-01-01

    With intensity-modulated radiotherapy (IMRT), a variety of user-defined dose distribution can be produced using inverse planning. The generalized equivalent uniform dose (gEUD) has been used in IMRT optimization as an alternative objective function to the conventional dose-volume-based criteria. The purpose of this study was to investigate the effectiveness of gEUD optimization to fine tune the dose distributions of IMRT plans. We analyzed the effect of gEUD-based optimization parameters on plan quality. The objective was to determine whether dose distribution to selected structures could be improved using gEUD optimization without adversely altering the doses delivered to other structures, as in sculpting. We hypothesized that by carefully defining gEUD parameters (EUD 0 and n) based on the current dose distributions, the optimization system could be instructed to search for alternative solutions in the neighborhood, and we could maintain the dose distributions for structures already satisfactory and improve dose for structures that need enhancement. We started with an already acceptable IMRT plan optimized with any objective function. The dose distribution was analyzed first. For structures that dose should not be changed, a higher value of n was used and EUD 0 was set slightly higher/lower than the EUD value at the current dose distribution for critical structures/targets. For structures that needed improvement in dose, a higher to medium value of n was used, and EUD 0 was set to the EUD value or slightly lower/higher for the critical structure/target at the current dose distribution. We evaluated this method in one clinical case each of head and neck, lung and prostate cancer. Dose volume histograms, isodose distributions, and relevant tolerance doses for critical structures were used for the assessment. We found that by adjusting gEUD optimization parameters, the dose distribution could be improved with only a few iterations. A larger value of n could lead to

  3. Optimized dose distribution of a high dose rate vaginal cylinder

    International Nuclear Information System (INIS)

    Li Zuofeng; Liu, Chihray; Palta, Jatinder R.

    1998-01-01

    Purpose: To present a comparison of optimized dose distributions for a set of high-dose-rate (HDR) vaginal cylinders calculated by a commercial treatment-planning system with benchmark calculations using Monte-Carlo-calculated dosimetry data. Methods and Materials: Optimized dose distributions using both an isotropic and an anisotropic dose calculation model were obtained for a set of HDR vaginal cylinders. Mathematical optimization techniques available in the computer treatment-planning system were used to calculate dwell times and positions. These dose distributions were compared with benchmark calculations with TG43 formalism and using Monte-Carlo-calculated data. The same dwell times and positions were used for a quantitative comparison of dose calculated with three dose models. Results: The isotropic dose calculation model can result in discrepancies as high as 50%. The anisotropic dose calculation model compared better with benchmark calculations. The differences were more significant at the apex of the vaginal cylinder, which is typically used as the prescription point. Conclusion: Dose calculation models available in a computer treatment-planning system must be evaluated carefully to ensure their correct application. It should also be noted that when optimized dose distribution at a distance from the cylinder surface is calculated using an accurate dose calculation model, the vaginal mucosa dose becomes significantly higher, and therefore should be carefully monitored

  4. Total skin electron irradiation: evaluation of dose uniformity throughout the skin surface

    International Nuclear Information System (INIS)

    Anacak, Yavuz; Arican, Zumre; Bar-Deroma, Raquel; Tamir, Ada; Kuten, Abraham

    2003-01-01

    In this study, in vivo dosimetic data of 67 total skin electron irradiation (TSEI) treatments were analyzed. Thermoluminescent dosimetry (TLD) measurements were made at 10 different body points for every patient. The results demonstrated that the dose inhomogeneity throughout the skin surface is around 15%. The homogeneity was better at the trunk than at the extratrunk points, and was worse when a degrader was used. There was minimal improvement of homogeneity in subsequent days of treatment

  5. Extrapolated surface dose measurements using a NdFeB magnetic deflector for 6 MV x-ray beams.

    Science.gov (United States)

    Damrongkijudom, N; Butson, M; Rosenfeld, A

    2007-03-01

    Extrapolated surface dose measurements have been performed using radiographic film to measure 2-Dimensional maps of skin and surface dose with and without a magnetic deflector device aimed at reducing surface dose. Experiments are also performed using an Attix parallel plate ionisation chamber for comparison to radiographic film extrapolation surface dose analysis. Extrapolated percentage surface dose assessments from radiographic film at the central axis of a 6 MV x-ray beam with magnetic deflector for field size 10 x 10 cm2, 15 x 15 cm2 and 20 x 20 cm2 are 9 +/- 3%, 13 +/- 3% and 16 +/- 3%, these compared to 14 +/- 3%, 19 +/- 3%, and 27 +/- 3% for open fields, respectively. Results from Attix chamber for the same field size are 12 +/- 1%, 15 +/- 1% and 18 +/- 1%, these compared to 16 +/- 1%, 21 +/- 1% and 27 +/- 1% for open fields, respectively. Results are also shown for profiles measured in-plane and cross-plane to the magnetic deflector and compared to open field data. Results have shown that the surface dose is reduced at all sites within the treatment field with larger reductions seen on one side of the field due to the sweeping nature of the designed magnetic field. Radiographic film extrapolation provides an advanced surface dose assessment and has matched well with Attix chamber results. Film measurement allows for easy 2 dimensional dose assessments.

  6. Pocket total dose meter

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; Endres, G.W.R.

    1984-10-01

    Laboratory measurements have demonstrated that it is possible to simultaneously measure absorbed dose and dose equivalent using a single tissue equivalent proportional counter. Small, pocket sized instruments are being developed to determine dose equivalent as the worker is exposed to mixed field radiation. This paper describes the electronic circuitry and computer algorithms used to determine dose equivalent in these devices

  7. On dose distribution comparison

    International Nuclear Information System (INIS)

    Jiang, Steve B; Sharp, Greg C; Neicu, Toni; Berbeco, Ross I; Flampouri, Stella; Bortfeld, Thomas

    2006-01-01

    In radiotherapy practice, one often needs to compare two dose distributions. Especially with the wide clinical implementation of intensity-modulated radiation therapy, software tools for quantitative dose (or fluence) distribution comparison are required for patient-specific quality assurance. Dose distribution comparison is not a trivial task since it has to be performed in both dose and spatial domains in order to be clinically relevant. Each of the existing comparison methods has its own strengths and weaknesses and there is room for improvement. In this work, we developed a general framework for comparing dose distributions. Using a new concept called maximum allowed dose difference (MADD), the comparison in both dose and spatial domains can be performed entirely in the dose domain. Formulae for calculating MADD values for various comparison methods, such as composite analysis and gamma index, have been derived. For convenience in clinical practice, a new measure called normalized dose difference (NDD) has also been proposed, which is the dose difference at a point scaled by the ratio of MADD to the predetermined dose acceptance tolerance. Unlike the simple dose difference test, NDD works in both low and high dose gradient regions because it considers both dose and spatial acceptance tolerances through MADD. The new method has been applied to a test case and a clinical example. It was found that the new method combines the merits of the existing methods (accurate, simple, clinically intuitive and insensitive to dose grid size) and can easily be implemented into any dose/intensity comparison tool

  8. Evaluation of absorbed doses at the interface solid surfaces - tritiated water solutions

    International Nuclear Information System (INIS)

    Postolache, Cristian; Matei, Lidia

    2003-01-01

    Studies concerning the isotopic exchange H/D/T in the system elemental hydrogen -- water and in the presence of platinum metals on hydrophobic supports as catalysts were carried out at ICSI (Institute of Cryogenics and Isotope Separations) - Rm. Valcea, Romania. Due to the very low energy of β-radiation emitted by tritium, the direct measurements of dose absorbed by the isotopic exchange catalyst using classical methods is practically impossible. For this purpose an evaluation model was developed. The volume of tritiated water which can irradiate the catalyst was represented by a hemisphere with the radius equal to the maximal rate of β-radiation emitted by tritium. The catalyst surface is represented by a circle with a 0.2 μm radius and the same centre as the circle of the hemisphere secant plane. Flow rate of absorbed dose is calculated with the relation: d (1/100)(Φ·E m /m), where d = dose flow rate, in rad/s, Φ total radiation flux interacting with the catalyst surface, expressed in erg and m = catalyst weight, in grams. Total flux of available radiation, Φ, was determined as a function of three parameters: a) total flow of tritium β-radiation emitted in the hemisphere of tritiated water, dependent on the volume and radioactive concentration; b) emission coefficient in the direction of the catalyst surface; c) attenuation coefficient (due to self-absorption) of the tritium β-radiation in the tritiated water body. (authors)

  9. Surface dose characterisation of the Varian Ir-192 HDR conical surface applicator set with a vertically orientated source

    Energy Technology Data Exchange (ETDEWEB)

    Buchauer, Konrad; Henke, Guido; Schiefer, Hans; Plasswilm, Ludwig [Kantonsspital St. Gallen, Department of Radiation Oncology, St. Gallen (Switzerland)

    2014-12-15

    Conical surface applicators with an Ir-192 high-dose-rate brachytherapy source are a common modality for the treatment of non-melanomatous skin cancer with high tumour control rates. Surface dose characterisation of the Varian Varisource GammaMed+ IX afterloader vertical type surface applicators is performed two dimensionally using high-resolution film dosimetry. The focus of this study was to determine if Varian surface applicators with a vertical source suffer from the dose distribution irregularities reported for comparable applicators. Our goal was to evaluate if the irregularities found affected treatment and dose output verification procedures. Ionisation chamber-based verification of applicator output was established according to guidelines provided by the manufacturer. For additional measurement of surface dose Gafchromic EBT3 film dosimetry was used. The term ''therapeutic dose'' was defined as 85 % of the prescribed dose level. For the 10 different applicator inserts evaluated, cold spots were observed. Mean cold spot size was 2.0 mm x 3.6 mm (± 0.6 mm). The cold spots were dosimetrically well below 85 % of the prescribed dose. The cold spot was situated 2.2 mm (1.4-2.7 mm) unilaterally from the central axis and caused general asymmetry in the dose profiles intersecting the cold spot area. A source tilt of approximately 8 (± 1 ) was determined for the source used for irradiation. A central underdosed area exceeding 15 % of the prescribed dose has not been previously reported. Source tilt was observed and found to affect clinical use and possibly treatment outcome in applicators using a vertically arranged source. Surface applicators with a vertically orientated source were subject to dose irregularities that could impact on chamber-based applicator output verification procedures. We recommend film dosimetry-backed applicator commissioning to avoid systematic errors. (orig.) [German] Konische Oberflaechenapplikatoren sind ein

  10. Moving gantry method for electron beam dose profile measurement at extended source-to-surface distances.

    Science.gov (United States)

    Fekete, Gábor; Fodor, Emese; Pesznyák, Csilla

    2015-03-08

    A novel method has been put forward for very large electron beam profile measurement. With this method, absorbed dose profiles can be measured at any depth in a solid phantom for total skin electron therapy. Electron beam dose profiles were collected with two different methods. Profile measurements were performed at 0.2 and 1.2 cm depths with a parallel plate and a thimble chamber, respectively. 108cm × 108 cm and 45 cm × 45 cm projected size electron beams were scanned by vertically moving phantom and detector at 300 cm source-to-surface distance with 90° and 270° gantry angles. The profiles collected this way were used as reference. Afterwards, the phantom was fixed on the central axis and the gantry was rotated with certain angular steps. After applying correction for the different source-to-detector distances and incidence of angle, the profiles measured in the two different setups were compared. Correction formalism has been developed. The agreement between the cross profiles taken at the depth of maximum dose with the 'classical' scanning and with the new moving gantry method was better than 0.5 % in the measuring range from zero to 71.9 cm. Inverse square and attenuation corrections had to be applied. The profiles measured with the parallel plate chamber agree better than 1%, except for the penumbra region, where the maximum difference is 1.5%. With the moving gantry method, very large electron field profiles can be measured at any depth in a solid phantom with high accuracy and reproducibility and with much less time per step. No special instrumentation is needed. The method can be used for commissioning of very large electron beams for computer-assisted treatment planning, for designing beam modifiers to improve dose uniformity, and for verification of computed dose profiles.

  11. SU-E-T-44: Angular Dependence of Surface Dose Enhancement Measured On Several Inhomogeneities Using Radiochromic EBT3 Films

    International Nuclear Information System (INIS)

    Jansen, A; Schoenfeld, A; Poppinga, D; Chofor, N; Poppe, B

    2014-01-01

    Purpose: The quantification of the relative surface dose enhancement in dependence on the angle of incidence and the atomic number Z of the surface material. Methods: Experiments were performed with slabs made of aluminum, titanium, copper, silver, dental gold and lead. The metal slabs with equal sizes of 1.0×8.0×8.8mm 3 were embedded in an Octavius 4D phantom (PTW Freiburg, Germany). Radiochromic EBT3 films were used to measure the surface dose for angles of incidence ranging from 0° to 90°. The setup with the metals slabs at the isocenter was irradiated with acceleration voltages of 6MV and 10MV. Water reference measurements were taken under equal conditions. Results: The surface dose enhancement is highest for angles of incidence below 30° and drops significantly for higher. The surface dose enhancement produced by lead and dental gold at 6MV showed a peak of 65%. At 90°, the surface dose enhancement dropped to 15% for both materials. The surface dose enhancements for silver, copper, titanium and aluminum were 45%, 32%, 22% and 12% at 0°, respectively. At an angle of incidence of 80°, the values dropped to 22%, 18%, 12% und 6%. The values for 10MV were very similar. Lead and dental gold showed peaks of 65% und 60%. Their values dropped to 18% at an angle of 90°. The surface dose enhancements for silver, copper, titanium and aluminum were 45%, 30%, 20% and 8% at 0°. At 80° the values dropped to 30%, 20%, 12% and 5%. A dependence of the magnitude of the surface dose enhancement on the atomic number of the surface material can be seen, which is in consistence with literature. Conclusion: The results show that the surface dose enhancements near implant materials with high Z-values should be taken into consideration in radio therapy, even when the angle of incidence is flat

  12. Angular dependence of the MOSFET dosimeter and its impact on in vivo surface dose measurement in breast cancer treatment.

    Science.gov (United States)

    Qin, S; Chen, T; Wang, L; Tu, Y; Yue, N; Zhou, J

    2014-08-01

    The focus of this study is the angular dependence of two types of Metal Oxide Semiconductor Field Effect Transistor (MOSFET) dosimeters (MOSFET20 and OneDose/OneDosePlus) when used for surface dose measurements. External beam radiationat different gantry angles were delivered to a cubic solid water phantom with a MOSFET placed on the top surface at CAX. The long axis of the MOSFET was oriented along the gantry axis of rotation, with the dosimeter (bubble side) facing the radiation source. MOSFET-measured surface doses were compared against calibrated radiochromic film readings. It was found that both types of MOSFET dosimeters exhibited larger than previously reported angular dependence when measuring surface dose in beams at large oblique angles. For the MOSFET20 dosimeter the measured surface dose deviation against film readings was as high as 17% when the incident angle was 72 degrees to the norm of the phantom surface. It is concluded that some MOSFET dosimeters may have a strong angular dependence when placed on the surface of water-equivalent material, even though they may have an isotropic angular response when surrounded by uniform medium. Extra on-surface calibration maybe necessary before using MOSFET dosimeters for skin dose measurement in tangential fields.

  13. Relationship between source-surface distance and patient dose in fluoroscopic X-ray examinations

    International Nuclear Information System (INIS)

    Suzuki, Shoichi; Asada, Yasuki; Nishi, Kazuta; Mizuno, Emiko; Hara, Natsue; Orito, Takeo; Kamei, Tetsuya; Koga, Sukehiko

    2000-01-01

    The International Electrotechnical Commission, IEC provided in its standard IEC 60601-1-3 (1994) to prevent the use during radioscopic irradiation of focal spot to skin distances less than 20 cm if the X-RAY EQUIPMENT is specified for RADIOSCOPY during surgery or 30 cm for other specified applications. This standard was reflected in the Japanese Industrial Standard JIS Z 4701-1997, which provided the minimum distance from focal spot to skin to be 30 cm for the use of a fluoroscopic and radiographic table (Under-table type). However, JIS had formerly provided the minimum distance to be 40 cm and so does the current Medical Treatment Law. The draft revision for the Medical Treatment Law currently discussed has consideration to adopt the value 30 cm in accordance with the current JIS. Our research intended to investigate the impact on the entrance surface dose for the change of the focal spot to skin distance from 40 cm to 30 cm. The result was 20-30% increase of the entrance surface dose for the focal spot to skin distance 30 cm. Taking patient exposure dose into account, we need further and more sufficient discussion with this result before adopting this value to the Medical Treatment Law. (author)

  14. When is a dose not a dose?

    International Nuclear Information System (INIS)

    Green, Patrick

    1992-01-01

    There is confusion over radiation dose limits between the International Commission on Radiological Protection, the National Radiological Protection Board and the Ministry of Agriculture, Fisheries and Food (MAFF), reports a Friends of the Earth's radiation campaigner. MAFF is suggesting the inadequate ICRP public dose limit does not apply to public exposures which arise from environmental contamination from past radioactive discharges. (author)

  15. Surface dose measurements under stretched, perforated thermoplast sheets and under protective wound dressings for high energy photon radiation

    International Nuclear Information System (INIS)

    Staudenraus, J.; Christ, G.

    2000-01-01

    Patient fixation masks made of perforated thermoplast sheets are widely used in radiotherapy. These masks in particular serve to immobilize the head and neck region during radiation treatment. We placed samples made of differently stretched, perforated mask material on the surface of a white polystyrene (RW3) phantom and measured for high energy photon beams from Co-60 radiation up to 25 MV bremsstrahlung the dose increase resulting from the build-up under the hole and bridge areas. Depending on the energy of the incident beam and the thickness of the stretched mask material we observed a dose increase under the bridges at the phantom surface of 55% up to 140% compared to the dose without a layer of mask material. Under a hole the dose increase is almost half the value found under a bridge. However, deeper than 1 mm under the phantom surface this difference in dose increase under holes and bridges decreases to less than 10%. The mean dose increase under a perforated thermoplast sheet is lower than the dose increase under a homogeneous sheet made of the same material with the same mean thickness. Radiation induced skin lesions or an ulcerating tumour, respectively, may require a protective wound dressing under a patient fixation mask during radiation therapy. Choosing a thin hydrocolloid wound dressing the additional dose increase of the skin, compared to the dose increase due to the fixation mask, can be kept low. (orig.) [de

  16. An assessment of methods for monitoring entrance surface dose in fluoroscopically guided interventional procedures

    International Nuclear Information System (INIS)

    Waite, J.C.; Fitzgerald, M.

    2001-01-01

    In the light of a growing awareness of the risks of inducing skin injuries as a consequence of fluoroscopically guided interventional procedures (FGIPs), this paper compares three methods of monitoring entrance surface dose (ESD). It also reports measurements of ESDs made during the period August 1998 to June 1999 on 137 patients undergoing cardiac, neurological and general FGIPs. Although the sample is small, the results reinforce the need for routine assessments to be made of ESDs in FGIPs. At present, the most reliable and accurate form of ESD measurement would seem to be arrays of TLDs. However, transducer based methods, although likely to be less accurate, have considerable advantages in relation to a continuous monitoring programme. It is also suggested that there may be the potential locally for threshold dose area product (DAP) values to be set for specific procedures. These could be used to provide early warning of the potential for skin injuries. (author)

  17. SU-F-T-371: Development of a Linac Monte Carlo Model to Calculate Surface Dose

    Energy Technology Data Exchange (ETDEWEB)

    Prajapati, S; Yan, Y; Gifford, K [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To generate and validate a linac Monte Carlo (MC) model for surface dose prediction. Methods: BEAMnrc V4-2.4.0 was used to model 6 and 18 MV photon beams for a commercially available linac. DOSXYZnrc V4-2.4.0 calculated 3D dose distributions in water. Percent depth dose (PDD) and beam profiles were extracted for comparison to measured data. Surface dose and at depths in the buildup region was measured with radiochromic film at 100 cm SSD for 4 × 4 cm{sup 2} and 10 × 10 cm{sup 2} collimator settings for open and MLC collimated fields. For the 6 MV beam, films were placed at depths ranging from 0.015 cm to 2 cm and for 18 MV, 0.015 cm to 3.5 cm in Solid Water™. Films were calibrated for both photon energies at their respective dmax. PDDs and profiles were extracted from the film and compared to the MC data. The MC model was adjusted to match measured PDD and profiles. Results: For the 6 MV beam, the mean error(ME) in PDD between film and MC for open fields was 1.9%, whereas it was 2.4% for MLC. For the 18 MV beam, the ME in PDD for open fields was 2% and was 3.5% for MLC. For the 6 MV beam, the average root mean square(RMS) deviation for the central 80% of the beam profile for open fields was 1.5%, whereas it was 1.6% for MLC. For the 18 MV beam, the maximum RMS for open fields was 3%, and was 3.1% for MLC. Conclusion: The MC model of a linac agreed to within 4% of film measurements for depths ranging from the surface to dmax. Therefore, the MC linac model can predict surface dose for clinical applications. Future work will focus on adjusting the linac MC model to reduce RMS error and improve accuracy.

  18. Natural radioactivity and external dose assessment of surface soils in Vietnam

    International Nuclear Information System (INIS)

    Huy, N. Q.; Hien, P. D.; Luyen, T. V.; Hoang, D. V.; Hiep, H. T.; Quang, N. H.; Long, N. Q.; Nhan, D. D.; Binh, N. T.; Hai, P. S.; Ngo, N. T.

    2012-01-01

    In this study, natural radioactivity in surface soils of Vietnam and external dose assessment to human population, deduced from activities of 226 Ra, 232 Th and 40 K nuclides, were determined. From 528 soil samples collected in 63 provinces of Vietnam, including five centrally governed cities, the average activities were obtained and equal to 42.77 ± 18.15 Bq kg -1 for 226 Ra, 59.84 ± 19.81 Bq kg -1 for 232 Th and 411.93 ± 230.69 Bq kg -1 for 40 K. The outdoor absorbed dose rates (OADRs) in air at 1 m above the ground level for 63 provinces were calculated, and their average value was 71.72 ± 24.72 nGy h -1 , with a range from 17.45 to 149.40 nGy h -1 . The population-weighted OADR of Vietnam was 66.70 nGy h -1 , which lies in the range of 18-93 nGy h -1 found in the World. From the OADRs obtained, it was estimated that the outdoor annual effective dose and indoor annual effective dose to the population were 0.082 and 0.458 mSv, which are higher than the corresponding values 0.07 and 0.41 mSv, respectively, of the World. The radium equivalent activity Ra eq and the external hazard index H ex of surface soils of Vietnam are lower than the corresponding permissible limits of 370 Bq kg -1 and 1, respectively. Therefore, soil from Vietnam is safe for the human population when it is used as a building material. (authors)

  19. Natural Radioactivity and External Dose Assessment of Surface Soils in Vietnam

    International Nuclear Information System (INIS)

    Huy, N.Q.; Hien, P.D.; Hoang, D.V.; Quang, N.H.; Long, N.Q.; Binh, N.T.; Hai, P.S.

    2012-01-01

    In this study, natural radioactivity in surface soils of Vietnam and external dose assessment to human population, deduces from activities of 226 Ra, 232 Th and 40 K nuclides, were determined. From 528 soil samples collected in 63 provinces of Vietnam, including five centrally governed cities, the average activities were obtained and equal to 42.77 ± 18.15 Bq kg -1 for 226 Ra, 59.84 ± 19.81 Bq kg -1 for 232 Th and 411.93 ± 230.69 Bq kg -1 for 40 K. The outdoor absorbed dose rates (OADRs) in air at 1 m above the ground level for 63 provinces were calculated, and their average value was 71.72 ± 24.72 nGy h -1 , with a range from 17.45 to 149.40 nGy h -1 . The population-weighted OADR of Vietnam was 66.70 nGy h -1 , which lies in the range of 18-93 nGy h -1 found in the World. From the OADR obtained, it was estimated that the outdoor annual effective dose and indoor annual effective dose to the population were 0.082 and 0.458 mSv, which are higher than the corresponding values 0.07 and 0.41 mSv, respectively, of the World. The radium equivalent activity Ra eq and the external hazard index H ex of surface soils of Vietnam are lower than the corresponding permissible limits of 370 Bq kg -1 and 1, respectively. Therefore, soil from Vietnam is safe for the human population when it used as a building material. (author)

  20. Dose from radiological examinations

    International Nuclear Information System (INIS)

    Imamura, Keiko; Uji, Teruyuki; Sakuyama, Keiko; Fujikawa, Mitsuhiro; Fujii, Masamichi

    1976-01-01

    Relatively high gonad doses, several hundred to one thousand mR, have been observed in case of pelvis, hip-joint, coccyx, lower abdomen and lumber examination. Dose to the ovary is especially high in barium enema and I.V.P. examinations. About 12 per cent of the 4-ray examination are high-dose. The gonad dose is relatively high in examination of abdomen and lower extremities, in infants. The dose to the eyes is especially high, 1.0 to 2.5R per exposure, in temporal bone and nasal sinuses tomography. X-ray doses have been compared with dose limits recommended by ICRP and with the gonad dose from natural radiations. The gonad dose in lumbar examination, barium enema, I.V.P. etc. is as high as the maximum permissible dose per year recommended by ICRP. Several devices have been made for dose reduction in the daily examinations: (1) separating the radiation field from the gonad by one centimeter decreases the gonad dose about one-half. (2) using sensitive screens and films. In pelvimetry and in infant hip-joint examination, the most sensitive screen and film are used. In the I.V.P. examination of adult, use of MS screen in place of FS screen decreases the dose to one-third, in combination with careful setting of radiation field, (3) use of grid increases the dose about 50 percent and the lead rubber protection (0.1mm lead equivalent) decreases the gonad dose to one-thirtieth in the spinal column examination of infant, (4) A lead protector, 1mm thickness and 2.5cm in diameter, on the eyes decreases the dose to about one-eighth in the face and nead examinations. These simple and effective methods for dose reduction. Should be carried out in as many examinations as possible in addition to observing dose limits recommended by ICRP. (Evans, J.)

  1. Dose-response relationship between periodontal inflamed surface area and HbA1c in type 2 Diabetics

    NARCIS (Netherlands)

    Nesse, Willem; Linde, Annemiek; Abbas, Frank; Spijkervet, Frederik Karst Lucien; Dijkstra, Pieter Ubele; de Brabander, Eric Carl; Gerstenbluth, Izzy; Vissink, Arjan

    Nesse W, Linde A, Abbas F, Spijkervet FKL, Dijkstra PU, de Brabander EC, Gerstenbluth I, Vissink A. Dose-response relationship between periodontal inflamed surface area and HbA1c in type 2 diabetics. J Clin Periodontol 2009; 36: 295-300. doi: 10.1111/j.1600-051X.2009.01377.x. A dose-response

  2. Direct Monte Carlo dose calculation using polygon-surface computational human model

    International Nuclear Information System (INIS)

    Jeong, Jong Hwi; Kim, Chan Hyeong; Yeom, Yeon Su; Cho, Sungkoo; Chung, Min Suk; Cho, Kun-Woo

    2011-01-01

    In the present study, a voxel-type computational human model was converted to a polygon-surface model, after which it was imported directly to the Geant4 code without using a voxelization process, that is, without converting back to a voxel model. The original voxel model was also imported to the Geant4 code, in order to compare the calculated dose values and the computational speed. The average polygon size of the polygon-surface model was ∼0.5 cm 2 , whereas the voxel resolution of the voxel model was 1.981 × 1.981 × 2.0854 mm 3 . The results showed a good agreement between the calculated dose values of the two models. The polygon-surface model was, however, slower than the voxel model by a factor of 6–9 for the photon energies and irradiation geometries considered in the present study, which nonetheless is considered acceptable, considering that direct use of the polygon-surface model does not require a separate voxelization process. (author)

  3. Annual absorbed dose rate at the surface of 38 hot and mineral springs in Iran

    Energy Technology Data Exchange (ETDEWEB)

    Bahreyni Toosi, M.; Orougi, M.H.; Sadeghzadeh, A.; Aghamir, A.; Jomehzadeh, A.; Zare, H. [Mashhad Univ. of Medical Sciences, Medical Physics Dep., Faculty of Medicine (Iran, Islamic Republic of)

    2006-07-01

    Full text of publication follows: Measurement of background radiation is very important from different points of view especially to human health. In some cases exposure rate near hot and mineral springs are higher than those of normal areas. The high background radiation of hot and mineral springs is primarily due to the presence of very high amounts of Ra 226 and its decay products. In this research, environmental gamma radiation of hot and mineral springs in Khorasan, Mazandaran and Sareeyn town in Ardabil province have been measured. Equipment used in this work included: a survey meter (R.D.S. -110), a tripod and an aluminium frame to hold the survey meter horizontally.R.D.S. -110 is a microprocessor controlled detector. This survey meter has been designed for monitoring X and rays and radiation. Measurements were carried out at one meter above water level in the vicinity of hot and mineral springs. Dose rates were recorded for one hour. The average of all recorded dose rates over one hour period was taken as the exposure rate for each station. The results indicate that in Khorasan province the highest and lowest annual absorbed dose rates were equal to 10.80 mSv/y at Shanigarmab and 0.52 mSv/y at Nasradin source respectively. In Mazandaran province maximum and minimum exposure rates equal to 54.4 and 0.53 mSv/y were obtained at the surface of Talleshmahalleh and Ghormerz sources. Exposure rates at the vicinity of Sarein sources were not very different and ranged from 1.39 to 1.59 mSv/y. The results indicate that in Khorasan province Shahingarmab hot spring has the highest annual absorbed dose rate (10.80 mSv/y) and Nasraddin in Sarbisheh has the lowest level of radiation (0.62 mSv/y). In Mazandaran province Taleshmahalleh hot mineral spring has the highest annual absorbed dose rate (54.41 mSv/y) and Ghormerz mineral spring has the lowest radiation level (0.53 mSv/y). Also in Sareeyn (in Ardabil province) Abechashm source has the highest annual absorbed dose

  4. Evaluation of surface and shallow depth dose reductions using a Superflab bolus during conventional and advanced external beam radiotherapy.

    Science.gov (United States)

    Yoon, Jihyung; Xie, Yibo; Zhang, Rui

    2018-03-01

    The purpose of this study was to evaluate a methodology to reduce scatter and leakage radiations to patients' surface and shallow depths during conventional and advanced external beam radiotherapy. Superflab boluses of different thicknesses were placed on top of a stack of solid water phantoms, and the bolus effect on surface and shallow depth doses for both open and intensity-modulated radiotherapy (IMRT) beams was evaluated using thermoluminescent dosimeters and ion chamber measurements. Contralateral breast dose reduction caused by the bolus was evaluated by delivering clinical postmastectomy radiotherapy (PMRT) plans to an anthropomorphic phantom. For the solid water phantom measurements, surface dose reduction caused by the Superflab bolus was achieved only in out-of-field area and on the incident side of the beam, and the dose reduction increased with bolus thickness. The dose reduction caused by the bolus was more significant at closer distances from the beam. Most of the dose reductions occurred in the first 2-cm depth and stopped at 4-cm depth. For clinical PMRT treatment plans, surface dose reductions using a 1-cm Superflab bolus were up to 31% and 62% for volumetric-modulated arc therapy and 4-field IMRT, respectively, but there was no dose reduction for Tomotherapy. A Superflab bolus can be used to reduce surface and shallow depth doses during external beam radiotherapy when it is placed out of the beam and on the incident side of the beam. Although we only validated this dose reduction strategy for PMRT treatments, it is applicable to any external beam radiotherapy and can potentially reduce patients' risk of developing radiation-induced side effects. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  5. Modeling dose-rate on/over the surface of cylindrical radio-models using Monte Carlo methods

    International Nuclear Information System (INIS)

    Xiao Xuefu; Ma Guoxue; Wen Fuping; Wang Zhongqi; Wang Chaohui; Zhang Jiyun; Huang Qingbo; Zhang Jiaqiu; Wang Xinxing; Wang Jun

    2004-01-01

    Objective: To determine the dose-rates on/over the surface of 10 cylindrical radio-models, which belong to the Metrology Station of Radio-Geological Survey of CNNC. Methods: The dose-rates on/over the surface of 10 cylindrical radio-models were modeled using the famous Monte Carlo code-MCNP. The dose-rates on/over the surface of 10 cylindrical radio-models were measured by a high gas pressurized ionization chamber dose-rate meter, respectively. The values of dose-rate modeled using MCNP code were compared with those obtained by authors in the present experimental measurement, and with those obtained by other workers previously. Some factors causing the discrepancy between the data obtained by authors using MCNP code and the data obtained using other methods are discussed in this paper. Results: The data of dose-rates on/over the surface of 10 cylindrical radio-models, obtained using MCNP code, were in good agreement with those obtained by other workers using the theoretical method. They were within the discrepancy of ±5% in general, and the maximum discrepancy was less than 10%. Conclusions: As if each factor needed for the Monte Carlo code is correct, the dose-rates on/over the surface of cylindrical radio-models modeled using the Monte Carlo code are correct with an uncertainty of 3%

  6. Influence of irradiation dose on laser-induced surface nanostructures on silicon

    Energy Technology Data Exchange (ETDEWEB)

    Varlamova, Olga [Brandenburgische Technische Universität BTU Cottbus, Platz der Deutschen Einheit 1, 03046 Cottbus (Germany); Cottbus JointLab, Platz der Deutschen Einheit 1, 03046 Cottbus (Germany); Bounhalli, Mourad [Brandenburgische Technische Universität BTU Cottbus, Platz der Deutschen Einheit 1, 03046 Cottbus (Germany); Laboratoire Hubert Curien, Université St. Etienne, Bâtiment F 18 Rue du Professeur Benoît Lauras, 42000 Saint-Etienne (France); Reif, Juergen, E-mail: REIF@TU-COTTBUS.DE [Brandenburgische Technische Universität BTU Cottbus, Platz der Deutschen Einheit 1, 03046 Cottbus (Germany); Cottbus JointLab, Platz der Deutschen Einheit 1, 03046 Cottbus (Germany)

    2013-08-01

    We report on the dependence of femtosecond laser-induced periodic surface structures on an increase of incident pulse number. On silicon, the patterns evolve from linear, parallel sub-wavelength ripples, grossly perpendicular to the laser polarization, via coalesced wider features parallel to the polarization, to a crater with periodically structured, pillar-like walls. Closer inspection of the patterns indicates that the different features always continue to exhibit reminiscence to the preceding lower-dose patterns, suggesting that, indeed, all patterns can be created by ONE single GENERAL formation process, as in self-organized structure formation, and the different structures/feature sizes are NOT due to DIFFERENT mechanisms.

  7. Radioactivity determination of sealed pure beta-sources by surface dose measurements and Monte Carlo simulations

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Heon [Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul (Korea, Republic of); Jung, Seongmoon [Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of); Choi, Kanghyuk; Son, Kwang-Jae; Lee, Jun Sig [Hanaro Applications Research, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Ye, Sung-Joon, E-mail: sye@snu.ac.kr [Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul (Korea, Republic of); Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of); Center for Convergence Research on Robotics, Advance Institutes of Convergence Technology, Seoul National University, Suwon (Korea, Republic of)

    2016-04-21

    This study aims to determine the activity of a sealed pure beta-source by measuring the surface dose rate using an extrapolation chamber. A conversion factor (cGy s{sup −1} Bq{sup −1}), which was defined as the ratio of surface dose rate to activity, can be calculated by Monte Carlo simulations of the extrapolation chamber measurement. To validate this hypothesis the certified activities of two standard pure beta-sources of Sr/Y-90 and Si/P-32 were compared with those determined by this method. In addition, a sealed test source of Sr/Y-90 was manufactured by the HANARO reactor group of KAERI (Korea Atomic Energy Research Institute) and used to further validate this method. The measured surface dose rates of the Sr/Y-90 and Si/P-32 standard sources were 4.615×10{sup −5} cGy s{sup −1} and 2.259×10{sup −5} cGy s{sup −1}, respectively. The calculated conversion factors of the two sources were 1.213×10{sup −8} cGy s{sup −1} Bq{sup −1} and 1.071×10{sup −8} cGy s{sup −1} Bq{sup −1}, respectively. Therefore, the activity of the standard Sr/Y-90 source was determined to be 3.995 kBq, which was 2.0% less than the certified value (4.077 kBq). For Si/P-32 the determined activity was 2.102 kBq, which was 6.6% larger than the certified activity (1.971 kBq). The activity of the Sr/Y-90 test source was determined to be 4.166 kBq, while the apparent activity reported by KAERI was 5.803 kBq. This large difference might be due to evaporation and diffusion of the source liquid during preparation and uncertainty in the amount of weighed aliquot of source liquid. The overall uncertainty involved in this method was determined to be 7.3%. We demonstrated that the activity of a sealed pure beta-source could be conveniently determined by complementary combination of measuring the surface dose rate and Monte Carlo simulations.

  8. Influence of irradiation dose on laser-induced surface nanostructures on silicon

    International Nuclear Information System (INIS)

    Varlamova, Olga; Bounhalli, Mourad; Reif, Juergen

    2013-01-01

    We report on the dependence of femtosecond laser-induced periodic surface structures on an increase of incident pulse number. On silicon, the patterns evolve from linear, parallel sub-wavelength ripples, grossly perpendicular to the laser polarization, via coalesced wider features parallel to the polarization, to a crater with periodically structured, pillar-like walls. Closer inspection of the patterns indicates that the different features always continue to exhibit reminiscence to the preceding lower-dose patterns, suggesting that, indeed, all patterns can be created by ONE single GENERAL formation process, as in self-organized structure formation, and the different structures/feature sizes are NOT due to DIFFERENT mechanisms.

  9. Electron dose-rate conversion factors for external exposure of the skin from uniformly deposited activity on the body surface

    International Nuclear Information System (INIS)

    Kocher, D.C.; Eckerman, K.F.

    1987-01-01

    Dose-rate conversion factors have been calculated for external exposure of the skin from electrons emitted by sources that are deposited uniformly on the body surface. The dose-rate factors are obtained from electron scaled point kernels developed by Berger. The dose-rate factors are calculated at depths of 4, 8, and 40 mg cm-2 below the body surface as recommended by Whitton, and at a depth of 7 mg cm-2 as recommended in ICRP Publication 26 (ICRP77). The dependence of the dose-rate factors at selected depths on the energy of the emitted electrons is displayed. The dose-rate factors for selected radionuclides of potential importance in radiological assessments are tabulated

  10. Response surfaces and sensitivity analyses for an environmental model of dose calculations

    Energy Technology Data Exchange (ETDEWEB)

    Iooss, Bertrand [CEA Cadarache, DEN/DER/SESI/LCFR, 13108 Saint Paul lez Durance, Cedex (France)]. E-mail: bertrand.iooss@cea.fr; Van Dorpe, Francois [CEA Cadarache, DEN/DTN/SMTM/LMTE, 13108 Saint Paul lez Durance, Cedex (France); Devictor, Nicolas [CEA Cadarache, DEN/DER/SESI/LCFR, 13108 Saint Paul lez Durance, Cedex (France)

    2006-10-15

    A parametric sensitivity analysis is carried out on GASCON, a radiological impact software describing the radionuclides transfer to the man following a chronic gas release of a nuclear facility. An effective dose received by age group can thus be calculated according to a specific radionuclide and to the duration of the release. In this study, we are concerned by 18 output variables, each depending of approximately 50 uncertain input parameters. First, the generation of 1000 Monte-Carlo simulations allows us to calculate correlation coefficients between input parameters and output variables, which give a first overview of important factors. Response surfaces are then constructed in polynomial form, and used to predict system responses at reduced computation time cost; this response surface will be very useful for global sensitivity analysis where thousands of runs are required. Using the response surfaces, we calculate the total sensitivity indices of Sobol by the Monte-Carlo method. We demonstrate the application of this method to one site of study and to one reference group near the nuclear research Center of Cadarache (France), for two radionuclides: iodine 129 and uranium 238. It is thus shown that the most influential parameters are all related to the food chain of the goat's milk, in decreasing order of importance: dose coefficient 'effective ingestion', goat's milk ration of the individuals of the reference group, grass ration of the goat, dry deposition velocity and transfer factor to the goat's milk.

  11. Insignificant levels of dose

    International Nuclear Information System (INIS)

    Webb, G.A.M.; McLean, A.S.

    1977-01-01

    The procedures recommended by the International Commission on Radiological Protection (ICRP) for making decisions concerning controllable sources of radiation exposure of the public include 'justification' and 'optimisation'. The tool recommended by the ICRP for reaching these decisions is collective dose or dose commitment supplemented by consideration of doses to individuals. In both these considerations the practical problem arises of whether very small doses to large numbers of people should contribute to the final decision-making process. It may be that at levels of dose which are small increments on natural background, the relationship between dose and effect is linear even though the slope may be close to zero. If so, collective dose is a meaningful concept and the calculation of total detriment for the purpose of justification could legitimately include all doses. In the calculation of collective doses for the purpose of optimisation, which involves decisions on how much money or resource should be allocated to dose reduction, it is necessary to appraise radiation detriment realistically. At low levels of dose to the individual such as those small by comparison with variations in natural background within the UK, the risk to the individual is such that his well-being will not be significantly changed by the presence or absence of the radiation dose. These small doses, which are well below the point at which an individual attaches significance, should not carry a societal significance. Societal acceptance of risk is analysed with a view to assessing a level of possible risk, and hence dose, below which resources should not in general be diverted to secure further reduction. A formulation for collective dose commitment is proposed incorporating a cut-off to exclude insignificant doses. The implications of this formulation in practical situations are discussed

  12. Development of a high precision dosimetry system for the measurement of surface dose rate distribution for eye applicators

    Energy Technology Data Exchange (ETDEWEB)

    Eichmann, Marion; Fluehs, Dirk; Spaan, Bernhard [Fakultaet Physik, Technische Universitaet Dortmund, D 44221 Dortmund (Germany); Klinische Strahlenphysik, Universitaetsklinikum Essen, D 45122 Essen (Germany); Fakultaet Physik, Technische Universitaet Dortmund, D 44221 Dortmund (Germany)

    2009-10-15

    Purpose: The therapeutic outcome of the therapy with ophthalmic applicators is highly dependent on the application of a sufficient dose to the tumor, whereas the dose applied to the surrounding tissue needs to be minimized. The goal for the newly developed apparatus described in this work is the determination of the individual applicator surface dose rate distribution with a high spatial resolution and a high precision in dose rate with respect to time and budget constraints especially important for clinical procedures. Inhomogeneities of the dose rate distribution can be detected and taken into consideration for the treatment planning. Methods: In order to achieve this, a dose rate profile as well as a surface profile of the applicator are measured and correlated with each other. An instrumental setup has been developed consisting of a plastic scintillator detector system and a newly designed apparatus for guiding the detector across the applicator surface at a constant small distance. It performs an angular movement of detector and applicator with high precision. Results: The measurements of surface dose rate distributions discussed in this work demonstrate the successful operation of the measuring setup. Measuring the surface dose rate distribution with a small distance between applicator and detector and with a high density of measuring points results in a complete and gapless coverage of the applicator surface, being capable of distinguishing small sized spots with high activities. The dosimetrical accuracy of the measurements and its analysis is sufficient (uncertainty in the dose rate in terms of absorbed dose to water is <7%), especially when taking the surgical techniques in positioning of the applicator on the eyeball into account. Conclusions: The method developed so far allows a fully automated quality assurance of eye applicators even under clinical conditions. These measurements provide the basis for future calculation of a full 3D dose rate

  13. Development of a high precision dosimetry system for the measurement of surface dose rate distribution for eye applicators.

    Science.gov (United States)

    Eichmann, Marion; Flühs, Dirk; Spaan, Bernhard

    2009-10-01

    The therapeutic outcome of the therapy with ophthalmic applicators is highly dependent on the application of a sufficient dose to the tumor, whereas the dose applied to the surrounding tissue needs to be minimized. The goal for the newly developed apparatus described in this work is the determination of the individual applicator surface dose rate distribution with a high spatial resolution and a high precision in dose rate with respect to time and budget constraints especially important for clinical procedures. Inhomogeneities of the dose rate distribution can be detected and taken into consideration for the treatment planning. In order to achieve this, a dose rate profile as well as a surface profile of the applicator are measured and correlated with each other. An instrumental setup has been developed consisting of a plastic scintillator detector system and a newly designed apparatus for guiding the detector across the applicator surface at a constant small distance. It performs an angular movement of detector and applicator with high precision. The measurements of surface dose rate distributions discussed in this work demonstrate the successful operation of the measuring setup. Measuring the surface dose rate distribution with a small distance between applicator and detector and with a high density of measuring points results in a complete and gapless coverage of the applicator surface, being capable of distinguishing small sized spots with high activities. The dosimetrical accuracy of the measurements and its analysis is sufficient (uncertainty in the dose rate in terms of absorbed dose to water is <7%), especially when taking the surgical techniques in positioning of the applicator on the eyeball into account. The method developed so far allows a fully automated quality assurance of eye applicators even under clinical conditions. These measurements provide the basis for future calculation of a full 3D dose rate distribution, which then can be used as input for

  14. Patient dose measurement and dose reduction in East Anglia (UK)

    International Nuclear Information System (INIS)

    Wade, J.P.; Goldstone, K.E.; Dendy, P.P.

    1995-01-01

    At the end of 1990 a programme of patient dose measurements was introduced as part of the quality assurance service already provided for X ray departments throughout the East Anglian Health Region (UK). Thermoluminescence dosemeters (TLDs) were used to measure over 1200 skin entrance surface doses for four common radiographic views in 33 hospitals in both the NHS and private sector. The four views were chosen to cover a wide range of equipment and techniques. The data collected have enabled Regional reference doses to be set which, for all views considered, fall below the National Radiological Protection Board (NRPB) Reference levels. In departments which exceeded reference levels, techniques were reviewed, improvements suggested and doses re-measured, in accordance with the recommended procedure for patient dose audit. A significant finding was that, given appropriate controls, X ray departments in the private sector could achieve the same acceptably low doses as NHS departments. (Author)

  15. Total dose meter development

    International Nuclear Information System (INIS)

    Brackenbush, L.W.

    1986-09-01

    This report describes an alarming ''pocket'' monitor/dosimeter, based on a tissue-equivalent proportional counter, that measure both neutron and gamma dose and determines dose equivalent for the mixed radiation field. This report details the operation of the device and provides information on: the necessity for a device to measure dose equivalent in mixed radiation fields; the mathematical theory required to determine dose equivalent from tissue equivalent proportional; the detailed electronic circuits required; the algorithms required in the microprocessor used to calculate dose equivalent; the features of the instrument; program accomplishments and future plans

  16. Dose reader CD-02

    International Nuclear Information System (INIS)

    Jakowiuk, A.; Kaluska, I.; Machaj, B.

    2005-01-01

    Dose Reader CD-02 is designed for measurement of dose from a long narrow band of dosimetric foil used for check up and control of electron beam dose during sterilization of materials and products on conveyor belt. Irradiated foil after processing (heating) is inserted into foil driving (moving) system and when the foil is moved across focused light beam the absorbed dose is measured and displayed at the same time at computer monitor (in form of a diagram). The absorbed dose is measured on the principle of light attenuation at selected light wavelength (foil absorbance is measured). (author)

  17. Dose conversion factors

    International Nuclear Information System (INIS)

    Kocher, D.C.; Eckerman, K.F.

    1992-01-01

    The following is discussed in this report: concepts and quantities used in calculating radiation dose from internal and external exposure. Tabulations of dose conversion factor for internal and external exposure to radionuclides. Dose conversion factors give dose per unit intake (internal) or dose per unit concentration in environment (external). Intakes of radionuclides for internal exposure and concentrations of radionuclides in environment for external exposure are assumed to be known. Intakes and concentrations are obtained, e.g., from analyses of environmental transport and exposure pathways. differences between dosimetry methods for radionuclides and hazardous chemicals are highlighted

  18. SU-E-T-348: Effect of Treatment Table and Immobilization Devices On Surface Dose When Using a GRID Technique

    Energy Technology Data Exchange (ETDEWEB)

    Gajdos, S; Donaghue, J [Akron General Medical Center, Akron, OH (United States)

    2015-06-15

    Purpose: To determine the increase of surface dose of MLC-designed GRID therapy in the presence of immobilization devices and treatment table. Methods: To create a GRID field, our facility utilizes an MLC consisting of four millimeter wide leaves. The field is designed to have aperture sizes of 0.8 cm X 0.8 cm with inter-aperture distance of 3.2 cm. Gafchromic EBT3 film was placed between the surface of a solid water phantom and the immobilization device. The treatment table was also present within the beam path. The devices consist of carbon fiber exterior shell. A piece of film was also placed at maximal depth for the photon energy of 10 MV. Image files were converted to dose per a calibration curve based on the selected red channel. The surface dose to maximum dose was established by comparing the ratio of seven centrally located aperture regions-of-interest and four adjacent inter-aperture regions-of-interest were measured with the available software tools. Results: With no devices present in beam path, the ratio of surface dose to maximum dose was 11.5% ± 0.3% for aperture region and 7.0% ± 0.1% for inter-aperture region. When devices are present, the ratio of surface dose to maximum dose was 45.2% ± 0.5% and 33.8% ± 1.1%, respectively. Due to the presence of devices, the surface dose increases in aperture region by 3.8 times or in the inter-aperture region by 4.7 times. Conclusion: The purpose of using GRID technique is to deliver a single fractional dose in range of 15–20 Gy to a bulky lesion while also preserving skin tolerance. The increase of surface dose due to devices placed in beam path may increase the chance of skin toxicity in GRID therapy. Care should be used to determine best manageable patient immobilization while considering skin dose especially for posteriorly located lesions.

  19. Sci-Thur PM – Brachytherapy 05: Surface Collimation Applied to Superficial Flap High Dose-Rate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Derek; Sabondjian, Eric; Lawrence, Kailin; Sankreacha, Raxa [University of Toronto, Carlo Fidani Peel Regional Cancer Center, Carlo Fidani Peel Regional Cancer Center, University of Toronto (Canada)

    2016-08-15

    Purpose: To apply surface collimation for superficial flap HDR skin brachytherapy utilizing common clinical resources and to demonstrate the potential for OAR dose reduction within a clinically relevant setting. Methods: Two phantom setups were used. 3 mm lead collimation was applied to a solid slab phantom to determine appropriate geometries relating to collimation and dwell activation. The same collimation was applied to the temple of an anthropomorphic head phantom to demonstrate lens dose reduction. Each setup was simulated and planned to deliver 400 cGy to a 3 cm circular target to 3 mm depth. The control and collimated irradiations were sequentially measured using calibrated radiochromic films. Results: Collimation for the slab phantom attenuated the dose beyond the collimator opening, decreasing the fall-off distances by half and reducing the area of healthy skin irradiated. Target coverage can be negatively impacted by a tight collimation margin, with the required margin approximated by the primary beam geometric penumbra. Surface collimation applied to the head phantom similarly attenuated the surrounding normal tissue dose while reducing the lens dose from 84 to 68 cGy. To ensure consistent setup between simulation and treatment, additional QA was performed including collimator markup, accounting for collimator placement uncertainties, standoff distance verification, and in vivo dosimetry. Conclusions: Surface collimation was shown to reduce normal tissue dose without compromising target coverage. Lens dose reduction was demonstrated on an anthropomorphic phantom within a clinical setting. Additional QA is proposed to ensure treatment fidelity.

  20. Sci-Thur PM – Brachytherapy 05: Surface Collimation Applied to Superficial Flap High Dose-Rate Brachytherapy

    International Nuclear Information System (INIS)

    Liu, Derek; Sabondjian, Eric; Lawrence, Kailin; Sankreacha, Raxa

    2016-01-01

    Purpose: To apply surface collimation for superficial flap HDR skin brachytherapy utilizing common clinical resources and to demonstrate the potential for OAR dose reduction within a clinically relevant setting. Methods: Two phantom setups were used. 3 mm lead collimation was applied to a solid slab phantom to determine appropriate geometries relating to collimation and dwell activation. The same collimation was applied to the temple of an anthropomorphic head phantom to demonstrate lens dose reduction. Each setup was simulated and planned to deliver 400 cGy to a 3 cm circular target to 3 mm depth. The control and collimated irradiations were sequentially measured using calibrated radiochromic films. Results: Collimation for the slab phantom attenuated the dose beyond the collimator opening, decreasing the fall-off distances by half and reducing the area of healthy skin irradiated. Target coverage can be negatively impacted by a tight collimation margin, with the required margin approximated by the primary beam geometric penumbra. Surface collimation applied to the head phantom similarly attenuated the surrounding normal tissue dose while reducing the lens dose from 84 to 68 cGy. To ensure consistent setup between simulation and treatment, additional QA was performed including collimator markup, accounting for collimator placement uncertainties, standoff distance verification, and in vivo dosimetry. Conclusions: Surface collimation was shown to reduce normal tissue dose without compromising target coverage. Lens dose reduction was demonstrated on an anthropomorphic phantom within a clinical setting. Additional QA is proposed to ensure treatment fidelity.

  1. Dose measurements in mammography

    International Nuclear Information System (INIS)

    Kainberger, F.; Kallinger, W.

    1977-01-01

    Dose measurements at the mamma during mammography were carried out in the form of direct measurement with thermoluminescent dosimetry. Measurement was done for the in- and outcoming doses at the mamma, the dose exposure of the sternal region and the scattered rays above the symphysis, the latter as parameter for the genetic radiation exposure. As expected, the dose of the smooth radiation used for mammography showed a strong decrease at the outcome point in comparison with the income point. Surprisingly high was the scattered radiation in the sternal region. A corresponding protection by lead plates could be taken into consideration. Extremely low is the scattered radiation above the symphysis. Even measurements with the very sensitive calcium fluoride dosimeters did not reveal any practically important dose in the symphysis region. Most measurement values remained below the determinable dose of 0.3mR. Some maximal values varied in the range of 3-1 mR. (orig.) [de

  2. Registration of radiation doses

    International Nuclear Information System (INIS)

    2000-02-01

    In Finland the Radiation and Nuclear Safety Authority (STUK) is maintaining the register (called Dose Register) of the radiation exposure of occupationally exposed workers in order to ensure compliance with the principles of optimisation and individual protection. The guide contains a description of the Dose Register and specifies the responsibilities of the party running a radiation practice to report the relevant information to the Dose Register

  3. An environmental dose experiment

    Science.gov (United States)

    Peralta, Luis

    2017-11-01

    Several radiation sources worldwide contribute to the delivered dose to the human population. This radiation also acts as a natural background when detecting radiation, for instance from radioactive sources. In this work a medium-sized plastic scintillation detector is used to evaluate the dose delivered by natural radiation sources. Calibration of the detector involved the use of radioactive sources and Monte Carlo simulation of the energy deposition per disintegration. A measurement of the annual dose due to background radiation to the body was then estimated. A dose value compatible with the value reported by the United Nations Scientific Committee on the Effects of Atomic Radiation was obtained.

  4. An environmental dose experiment

    International Nuclear Information System (INIS)

    Peralta, Luis

    2017-01-01

    Several radiation sources worldwide contribute to the delivered dose to the human population. This radiation also acts as a natural background when detecting radiation, for instance from radioactive sources. In this work a medium-sized plastic scintillation detector is used to evaluate the dose delivered by natural radiation sources. Calibration of the detector involved the use of radioactive sources and Monte Carlo simulation of the energy deposition per disintegration. A measurement of the annual dose due to background radiation to the body was then estimated. A dose value compatible with the value reported by the United Nations Scientific Committee on the Effects of Atomic Radiation was obtained. (paper)

  5. Doses from portable gauges

    International Nuclear Information System (INIS)

    Linauskas, S.H.

    1988-08-01

    Field studies to measure actual radiation exposures of operators of commercial moisture-density gauges were undertaken in several regions of Canada. Newly developed bubble detector dosimeter technology and conventional dosimetry such as thermoluminescent dosimeters (TLDs), integrating electronic dosimeters (DRDs), and CR-39 neutron track-etch detectors were used to estimate the doses received by 23 moisture-density gauge operators and maintenance staff. These radiation dose estimates were supported by mapping radiation fields and accounting for the time an operator was near a gauge. Major findings indicate that gauge maintenance and servicing workers were more likely than gauge operators to receive exposures above the level of 5 mSv, and that neutron doses were roughly the same as gamma doses. Gauge operators receive approximately 75% of their dose when transporting and carrying the gauge. Dose to their hands is similar to the dose to their trunks, but the dose to their feet area is 6 to 30 times higher. Gamma radiation is the primary source of radiation contributing to operator dose

  6. Radiation dose in vertebroplasty

    International Nuclear Information System (INIS)

    Mehdizade, A.; Lovblad, K.O.; Wilhelm, K.E.; Somon, T.; Wetzel, S.G.; Kelekis, A.D.; Yilmaz, H.; Abdo, G.; Martin, J.B.; Viera, J.M.; Ruefenacht, D.A.

    2004-01-01

    We wished to measure the absorbed radiation dose during fluoroscopically controlled vertebroplasty and to assess the possibility of deterministic radiation effects to the operator. The dose was measured in 11 consecutive procedures using thermoluminescent ring dosimeters on the hand of the operator and electronic dosimeters inside and outside of the operator's lead apron. We found doses of 0.022-3.256 mGy outside and 0.01-0.47 mGy inside the lead apron. Doses on the hand were higher, 0.5-8.5 mGy. This preliminary study indicates greater exposure to the operator's hands than expected from traditional apron measurements. (orig.)

  7. Patient dose measurement and dose reduction in chest radiography

    Directory of Open Access Journals (Sweden)

    Milatović Aleksandra A.

    2014-01-01

    Full Text Available Investigations presented in this paper represent the first estimation of patient doses in chest radiography in Montenegro. In the initial stage of our study, we measured the entrance surface air kerma and kerma area product for chest radiography in five major health institutions in the country. A total of 214 patients were observed. We reported the mean value, minimum and third quartile values, as well as maximum values of surface air kerma and kerma area product of patient doses. In the second stage, the possibilities for dose reduction were investigated. Mean kerma area product values were 0.8 ± 0.5 Gycm2 for the posterior-anterior projection and 1.6 ± 0.9 Gycm2 for the lateral projection. The max/min ratio for the entrance surface air kerma was found to be 53 for the posterior-anterior projection and 88 for the lateral projection. Comparing the results obtained in Montenegro with results from other countries, we concluded that patient doses in our medical centres are significantly higher. Changes in exposure parameters and increased filtration contributed to a dose reduction of up to 36% for posterior-anterior chest examinations. The variability of the estimated dose values points to a significant space for dose reduction throughout the process of radiological practice optimisation.

  8. The patient dose survey and dose reduction in diagnostic radiology

    International Nuclear Information System (INIS)

    Dang Thanh Luong; Duong Van Vinh; Ha Ngoc Thach

    2000-01-01

    This paper presented the results of the patient dose survey in some hospitals in Hanoi from 1995 to 1997. The main investigated types of the X-ray examination were: Chest PA, LAT; Skull PA/AP, LAT; Lumbar spine AP, LAT; and Pelvis AP. The fluctuation of the entrance surface doses (ESD) was too large, even in the same type of X-ray examination and X-ray facility. It was found that the ratio of maximum and minimum ESD were ranged from 1.5 to 18. The mean values of ESD for chest and skull were higher than CEC recommended values, while the mean values of lumbar spine and pelvis were smaller than that of CEC recommended values. The result of dose intercomparison was also reported. Some methods of dose reduction were applied for improving the patient dose in X-ray departments such as a high kV technique, high sensitive screen-film combination. (author)

  9. Development of mathematical model for estimation of entrance surface dose in mammography

    International Nuclear Information System (INIS)

    Abdelgani, Yassir Mohammed Tahir

    2013-05-01

    Computer simulation is a convenient and frequently used tool in the study of x-ray mammography, for the design of novel detector systems, the evaluation of dose deposition, x-ray technique optimization, and other applications. An important component in the simulation process is the accurate computer generation of x-ray spectra. A computer model for the generation of x-ray spectra in the mammographic energy rang from 18 keV to 40 ke V has been developed by Boone et al. Due to the lack of QC and dose measurement tools, in addition to unavailability of medical physics, a mathematical tool was developed for estimation of patient exposure and entrance dose. The proposed model require no assumptions concerning the physics of x-ray production in an x-ray tube, but rather makes use of x-ray spectra recently measured experimentally by John M Boone (Department of Radiology, University of California). Using experimental dose measurements for specific tube voltage and tube current the generated x-ray spectra were calibrated. The spectrum calibration factors show a tube voltage dependency. From the calibrated x-ray spectrum, the exposure and entrance dose were estimated for different k Vp and m A. Results show good agreement between the measured and estimated values for tube voltage between 18 to 45 k Vp with a good correlation of nearly 1 and equal slope. The maximum estimated different between the measured and the simulated dose is approximately equal to 0.07%.(Author)

  10. SUDOQU: a new dose model to derive criteria for surface contamination of non-food (consumer) goods, containers and conveyances

    International Nuclear Information System (INIS)

    Van Dillen, Teun

    2015-01-01

    The Fukushima nuclear accident (Japan, 11 March 2011) revealed the need for well-founded criteria for surface contamination and associated screening levels related to the import of non-food (consumer) goods, containers and conveyances. The only available European-harmonised criteria are those laid down in the IAEA transport regulations, but these criteria date back from the early 1960's and only apply to the safe transport of radioactive materials. The main problem is that a generic dose-assessment model for consumer products is missing. Therefore, RIVM (National Institute for Public Health and the Environment) developed a new methodology entitled SUDOQU (Surface Dose Quantification) to calculate the annual effective dose for both consumers and non-radiological workers, addressing issues of removability of surface contamination. The methodology can be used to derive criteria and screening levels for surface contamination and could serve as a useful tool for policy-makers and radiation-protection specialists. (authors)

  11. Fast in vivo volume dose reconstruction via reference dose perturbation

    International Nuclear Information System (INIS)

    Lu, Weiguo; Chen, Mingli; Mo, Xiaohu; Parnell, Donald; Olivera, Gustavo; Galmarini, Daniel

    2014-01-01

    Purpose: Accurate on-line reconstruction of in-vivo volume dose that accounts for both machine and patient discrepancy is not clinically available. We present a simple reference-dose-perturbation algorithm that reconstructs in-vivo volume dose fast and accurately. Methods: We modelled the volume dose as a function of the fluence map and density image. Machine (output variation, jaw/leaf position errors, etc.) and patient (setup error, weight loss, etc.) discrepancies between the plan and delivery were modelled as perturbation of the fluence map and density image, respectively. Delivered dose is modelled as perturbation of the reference dose due to change of the fluence map and density image. We used both simulated and clinical data to validate the algorithm. The planned dose was used as the reference. The reconstruction was perturbed from the reference and accounted for output-variations and the registered daily image. The reconstruction was compared with the ground truth via isodose lines and the Gamma Index. Results: For various plans and geometries, the volume doses were reconstructed in few seconds. The reconstruction generally matched well with the ground truth. For the 3%/3mm criteria, the Gamma pass rates were 98% for simulations and 95% for clinical data. The differences mainly appeared on the surface of the phantom/patient. Conclusions: A novel reference-dose-perturbation dose reconstruction model is presented. The model accounts for machine and patient discrepancy from planning. The algorithm is simple, fast, yet accurate, which makes online in-vivo 3D dose reconstruction clinically feasible.

  12. Evaluation of surface and build-up region dose for intensity-modulated radiation therapy in head and neck cancer

    International Nuclear Information System (INIS)

    Chung, Heeteak; Jin, Hosang; Dempsey, James F.; Liu, Chihray; Palta, Jatinder; Suh, Tae-Suk; Kim, Siyong

    2005-01-01

    Despite much development, there remains dosimetric uncertainty in the surface and build-up regions in intensity-modulated radiation therapy treatment plans for head and neck cancers. Experiments were performed to determine the dosimetric discrepancies in the surface and build-up region between the treatment planning system (TPS) prediction and experimental measurement using radiochromic film. A head and neck compression film phantom was constructed from two semicylindrical solid water slabs. Treatment plans were generated using two commercial TPSs (PINNACLE3 and CORVUS) for two cases, one with a shallow (∼0.5 cm depth) target and another with a deep (∼6 cm depth) target. The plans were evaluated for a 54 Gy prescribed dose. For each case, two pieces of radiochromic film were used for dose measurement. A small piece of film strip was placed on the surface and another was inserted within the phantom. Overall, both TPSs showed good agreement with the measurement. For the shallow target case, the dose differences were within ±300 cGy (5.6% with respect to the prescribed dose) for PINNACLE3 and ±240 cGy (4.4%) for CORVUS in 90% of the region of interest. For the deep target case, the dose differences were ±350 (6.5%) for PINNACLE3 and ±260 cGy (4.8%) for CORVUS in 90% of the region of interest. However, it was found that there were significant discrepancies from the surface to about 0.2 cm in depth for both the shallow and deep target cases. It was concluded that both TPSs overestimated the surface dose for both shallow and deep target cases. The amount of overestimation ranges from 400 to 1000 cGy (∼7.4% to 18.5% with respect to the prescribed dose, 5400 cGy)

  13. Skin dose estimation for various beam modifiers and source-to-surface distances for 6MV photons

    Directory of Open Access Journals (Sweden)

    Yadav Girigesh

    2009-01-01

    Full Text Available The purpose of this study was to learn the skin dose estimation for various beam modifiers at various source-to-surface distances (SSDs for a 6 MV photon. Surface and buildup region doses were measured with an acrylic slab phantom and Markus 0.055 cc parallel plate (PP ionization chamber. Measurements were carried out for open fields, motorized wedge fields, acrylic block tray fields ranging from 3 x 3 cm 2 to 30 x 30 cm 2 . Twenty-five percent of the field was blocked with a cerrobend block and a Multileaf collimator (MLC. The effect of the blocks on the skin dose was measured for a 20 x 20 cm 2 field size, at 80 cm, 100 cm and 120 cm SSD. During the use of isocentric treatments, whereby the tumor is positioned at 100 cm from the source, depending on the depth of the tumor and size of the patient, the SSD can vary from 80 cm to 100 cm. To achieve a larger field size, the SSD can also be extended up to 120 cm at times. The skin dose increased as field size increased. The skin dose for the open 10 x10 cm 2 field was 15.5%, 14.8% and 15.5% at 80 cm, 100 cm and 120 cm SSDs, respectively. The skin dose due to a motorized 60 0 wedge for the 10 x 10 cm 2 field was 9.9%, 9.5%, and 9.5% at 80 cm, 100 cm and 120 cm SSDs. The skin dose due to acrylic block tray, of thickness 1.0 cm for a 10 x 10 cm 2 field was 27.0%, 17.2% and 16.1% at 80, 100 and 120 cm SSD respectively. Due to the use of an acrylic block tray, the surface dose was increased for all field sizes at the above three SSDs and the percentage skin dose was more dominant at the lower SSD and larger field size. The skin dose for a 30 x 30 cm 2 field size at 80 cm SSD was 38.3% and it was 70.4% for the open and acrylic block tray fields, respectively. The skin doses for motorized wedge fields were lower than for open fields. The effect of SSDs on the surface dose for motorized 60° wedge fields was not significant for a small field size (difference was less than 1% up to a 15 x 15 cm 2 field size

  14. Effective dose equivalent

    International Nuclear Information System (INIS)

    Huyskens, C.J.; Passchier, W.F.

    1988-01-01

    The effective dose equivalent is a quantity which is used in the daily practice of radiation protection as well as in the radiation hygienic rules as measure for the health risks. In this contribution it is worked out upon which assumptions this quantity is based and in which cases the effective dose equivalent can be used more or less well. (H.W.)

  15. Doses from radiation exposure

    International Nuclear Information System (INIS)

    Menzel, H-G.; Harrison, J.D.

    2012-01-01

    Practical implementation of the International Commission on Radiological Protection’s (ICRP) system of protection requires the availability of appropriate methods and data. The work of Committee 2 is concerned with the development of reference data and methods for the assessment of internal and external radiation exposure of workers and members of the public. This involves the development of reference biokinetic and dosimetric models, reference anatomical models of the human body, and reference anatomical and physiological data. Following ICRP’s 2007 Recommendations, Committee 2 has focused on the provision of new reference dose coefficients for external and internal exposure. As well as specifying changes to the radiation and tissue weighting factors used in the calculation of protection quantities, the 2007 Recommendations introduced the use of reference anatomical phantoms based on medical imaging data, requiring explicit sex averaging of male and female organ-equivalent doses in the calculation of effective dose. In preparation for the calculation of new dose coefficients, Committee 2 and its task groups have provided updated nuclear decay data (ICRP Publication 107) and adult reference computational phantoms (ICRP Publication 110). New dose coefficients for external exposures of workers are complete (ICRP Publication 116), and work is in progress on a series of reports on internal dose coefficients to workers from inhaled and ingested radionuclides. Reference phantoms for children will also be provided and used in the calculation of dose coefficients for public exposures. Committee 2 also has task groups on exposures to radiation in space and on the use of effective dose.

  16. Gonad dose in cineurethrocystography

    International Nuclear Information System (INIS)

    Ardran, G.M.; Dixon-Brown, A.; Fursdon, P.S.

    1978-01-01

    The technical factors used for cineurethrocystography for the true lateral projection in females are given. The mid-line radiation dose has been measured with LiF TLD inserted into the vagina in 19 examinations. The average dose recorded was 148 mrad, the range being 50 to 306 mrad, the average number of cine frames exposed was 96. Data obtained using a Rando phantom indicated that the average ovary dose would be 30% greater than the mid-line dose since the near ovary receives a higher dose than the more distant one. The technique used for men is also given, the average gonad dose in six men being 123 mrad, range 56 to 243 mrad when simple lead foil gonad protection was used; the average number of cine frames was 107. The dose in one man without gonad protection was 1575 mrad for 112 cine frames. The results for both sexes compare favourably with those of others reported in the literature and with gonad doses recorded in typical IVP examinations. (author)

  17. Internal dose estimates

    International Nuclear Information System (INIS)

    Wrenn, M.E.

    1977-01-01

    Internal doses, the procedures for making them and their significance has been reviewed. Effects of uranium, radium, lead-210, polonium-210, thorium in man are analysed based on data from tables and plots. Dosimetry of some ingested nuclides and inhalation dose due to radon-222, radon-220 and their daugther products are discussed [pt

  18. Sensitivity of coefficients for converting entrance surface dose and kerma-area product to effective dose and energy imparted to the patient

    International Nuclear Information System (INIS)

    Wise, K.N.; Sandborg, M.; Persliden, J.; Alm Carlsson, G.

    1999-01-01

    We investigate the sensitivity of the conversions from entrance surface dose (ESD) or kerma-area product (KAP) to effective dose (E) or to energy imparted to the patient (ε) to the likely variations in tube potential, field size, patient size and sex which occur in clinical work. As part of a factorial design study for chest and lumbar spine examinations, the tube potentials were varied to be ±10% of the typical values for the examinations while field sizes and the positions of the field centres were varied to be representative of values drawn from measurements on patient images. Variation over sex and patient size was based on anthropomorphic phantoms representing males and females of ages 15 years (small adult) and 21 years (reference adult). All the conversion coefficients were estimated using a mathematical phantom programmed with the Monte Carlo code EGS4 for all factor combinations and analysed statistically to derive factor effects. In general, the factors studied behaved independently in the sense that interaction of the physical factors generally gave no more than a 5% variation in a conversion coefficient. Taken together, variation of patient size, sex, field size and field position can lead to significant variation of E/KAP by up to a factor of 2, of E/ESD by up to a factor of 3, of ε/KAP by a factor of 1.3 and of ε/ESD by up to a factor of 2. While KAP is preferred to determine ε, the results show no strong preference of KAP over ESD in determining E. The mean absorbed dose D-bar in the patient obtained by dividing ε (determined using KAP) by the patient's mass was found to be the most robust measure of E. (author)

  19. Occupational dose constraint

    International Nuclear Information System (INIS)

    Heilbron Filho, Paulo Fernando Lavalle; Xavier, Ana Maria

    2005-01-01

    The revision process of the international radiological protection regulations has resulted in the adoption of new concepts, such as practice, intervention, avoidable and restriction of dose (dose constraint). The latter deserving of special mention since it may involve reducing a priori of the dose limits established both for the public and to individuals occupationally exposed, values that can be further reduced, depending on the application of the principle of optimization. This article aims to present, with clarity, from the criteria adopted to define dose constraint values to the public, a methodology to establish the dose constraint values for occupationally exposed individuals, as well as an example of the application of this methodology to the practice of industrial radiography

  20. Effect on moisture permeability of typewriting on unit dose package surfaces.

    Science.gov (United States)

    Rackson, J T; Zellhofer, M J; Birmingham, P H

    1984-10-01

    The effects of typewriting on labels of two unit dose packages with respect to moisture permeability were examined. Using an electric typewriter, a standard label format was imprinted on two different types of class A unit dose packages: (1) a heat-sealed paper-backed foil and cellofilm strip pouch, and (2) a copolyester and polyethylene multiple-cup blister with a heat-sealed paper-backed foil and cellofilm cover. The labels were typed at various typing-element impact settings. The official USP test for water permeation was then performed on typed packages and untyped control packages. The original untyped packages were confirmed to be USP class A quality. The packages for which successively harder impact settings were used showed a corresponding increase in moisture permeability. This resulted in a lowering of USP package ratings from class A to class B and D, some of which would be unsuitable for use in any unit dose system under current FDA repackaging standards. Typing directly onto the label of a unit dose package before it is sealed will most likely damage the package and possibly make it unfit for use. Pharmacists who must type labels for the unit dose packages studied should use the lowest possible typewriter impact setting and test for damage using the USP moisture-permeation test.

  1. Dose response relationship at low doses

    International Nuclear Information System (INIS)

    Schull, W.J.

    1992-01-01

    The data that have accrued in Hiroshima and Nagasaki on the effects of ionizing radiation on the developing human brain are reviewed. Effects considered are severe mental retardation, lowered IQ scores, decline in school performance, seizures, other neuropsychological effects, and small head size. All these factors may be related to radiation doses received by the mother during pregnancy. (L.L.) 3 figs., tab., 7 refs

  2. Entrance surface dose distribution and organ dose assessment for cone-beam computed tomography using measurements and Monte Carlo simulations with voxel phantoms

    Science.gov (United States)

    Baptista, M.; Di Maria, S.; Vieira, S.; Vaz, P.

    2017-11-01

    Cone-Beam Computed Tomography (CBCT) enables high-resolution volumetric scanning of the bone and soft tissue anatomy under investigation at the treatment accelerator. This technique is extensively used in Image Guided Radiation Therapy (IGRT) for pre-treatment verification of patient position and target volume localization. When employed daily and several times per patient, CBCT imaging may lead to high cumulative imaging doses to the healthy tissues surrounding the exposed organs. This work aims at (1) evaluating the dose distribution during a CBCT scan and (2) calculating the organ doses involved in this image guiding procedure for clinically available scanning protocols. Both Monte Carlo (MC) simulations and measurements were performed. To model and simulate the kV imaging system mounted on a linear accelerator (Edge™, Varian Medical Systems) the state-of-the-art MC radiation transport program MCNPX 2.7.0 was used. In order to validate the simulation results, measurements of the Computed Tomography Dose Index (CTDI) were performed, using standard PMMA head and body phantoms, with 150 mm length and a standard pencil ionizing chamber (IC) 100 mm long. Measurements for head and pelvis scanning protocols, usually adopted in clinical environment were acquired, using two acquisition modes (full-fan and half fan). To calculate the organ doses, the implemented MC model of the CBCT scanner together with a male voxel phantom ("Golem") was used. The good agreement between the MCNPX simulations and the CTDIw measurements (differences up to 17%) presented in this work reveals that the CBCT MC model was successfully validated, taking into account the several uncertainties. The adequacy of the computational model to map dose distributions during a CBCT scan is discussed in order to identify ways to reduce the total CBCT imaging dose. The organ dose assessment highlights the need to evaluate the therapeutic and the CBCT imaging doses, in a more balanced approach, and the

  3. Effect of various physical parameters on surface and build-up dose for 15-MV X-rays

    International Nuclear Information System (INIS)

    Yadav, Girigesh; Yadav, R.S.; Kumar, Alok

    2010-01-01

    The purpose of this study was to find out the effect of various physical parameters on the skin and build-up doses of 15-MV photon beams. The effects of field dimensions, acrylic shadow tray, focus to-skin distance (FSD) on surface and buildup dose were determined for open, motorized 60 deg wedge (MW) and blocked fields. A 'Markus' plane parallel plate chamber was used for these measurements in an Elekta (6-15MV) linear accelerator. The surface dose for MW fields was lower than the dose for an open field, but the trend reversed for large fields and higher degree wedges. With the use of an acrylic shadow tray, the surface dose increased for all field sizes, but the increase was dominant for large fields. The surface dose for blocked fields was lower than the dose for open fields. The percentage depth dose of 10 x 10 cm 2 field at surface (PDD 0 ) for open beam were 13.89%, 11.71%, and 10.74% at 80 cm, 100 cm, and 120 cm FSD, respectively. The blocking tray increased PDD 0 of 10 x 10 cm 2 field to 26.29%, 14.01%, and 11.53%, while the motorized 60 deg wedge decreased PDD 0 to 11.32%, 9.7%, and 8.9 % at these FSDs. The maximum PDD difference seen at surface (i.e. skin) for 5x5 cm 2 , 15x15 cm 2 , and 30x30 cm 2 are 0.5%, 4.6%, and 5.6% for open field and 0.9%, 4.7%, and 7.2% for motorized 60 deg wedge field, when FSDs varied from 80 cm to 120 cm. The maximum PDD difference seen at surface for 5x5 cm 2 , 15x15 cm 2 , and 30x30 cm 2 fields are 5.6%, 22.8%, and 29.6%, respectively, for a 1.0-cm perspex-blocking tray as the FSD is changed. The maximum PDD difference was seen at the surface (i.e. skin) and this decreased with increasing depth. (author)

  4. Quantification of acute vocal fold epithelial surface damage with increasing time and magnitude doses of vibration exposure.

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Kojima

    Full Text Available Because the vocal folds undergo repeated trauma during continuous cycles of vibration, the epithelium is routinely susceptible to damage during phonation. Excessive and prolonged vibration exposure is considered a significant predisposing factor in the development of vocal fold pathology. The purpose of the present study was to quantify the extent of epithelial surface damage following increased time and magnitude doses of vibration exposure using an in vivo rabbit phonation model. Forty-five New Zealand white breeder rabbits were randomized to nine groups and received varying phonation time-doses (30, 60, or 120 minutes and magnitude-doses (control, modal intensity phonation, or raised intensity phonation of vibration exposure. Scanning electron microscopy and transmission electron microscopy was used to quantify the degree of epithelial surface damage. Results revealed a significant reduction in microprojection density, microprojection height, and depth of the epithelial surface with increasing time and phonation magnitudes doses, signifying increased epithelial surface damage risk with excessive and prolonged vibration exposure. Destruction to the epithelial cell surface may provide significant insight into the disruption of cell function following prolonged vibration exposure. One important goal achieved in the present study was the quantification of epithelial surface damage using objective imaging criteria. These data provide an important foundation for future studies of long-term tissue recovery from excessive and prolonged vibration exposure.

  5. Treatment of skin carcinomas of the face by high-dose-rate brachytherapy and custom-made surface molds

    International Nuclear Information System (INIS)

    Guix, Benjamin; Finestres, Fernando; Tello, Jose-Ignacio; Palma, Cesar; Martinez, Antonio; Guix, Jose-Ramon; Guix, Ricardo

    2000-01-01

    Purpose: To analyze the results obtained in a prospective group of patients with basal or squamous cell skin carcinomas of the face treated by high-dose-rate (HDR) brachytherapy via custom-made surface molds. Methods and Materials: A total of 136 patients with basal or squamous cell carcinomas of the face were treated between March 1992 and March 1997 by surface molds and HDR brachytherapy with iridium-192. Nineteen patients were treated with standard Brock applicators and 117 patients with custom-made polymethyl methacrylate applicators, built over a plaster mold obtained of the patient's face. Minimum dose administered to the tumor was 6000 to 6500 cGy in 33 to 36 fractions at 180 cGy/fraction in lesions of up to 4 cm. Lesions greater than 4 cm were boosted up to 7500-8000 cGy after a 3-week pause. Results: With the custom-made surface molds, the dose distribution was uniform in the surface of the skin and at 5 mm depth in the whole area of the applicator. Differences between the areas of maximum and minimum dose at this depth never reached values higher than 5% of the prescribed dose. At the edges of the custom-made molds dose gradient was sharp, with the detected dose at 5 mm from the applicator being negligible. All the patients were complete responders. There were 3 local recurrences, 1/73 patients treated for primary tumor and 2/63 patients treated for recurrent tumor. Actuarial local control at 5 years for all patients was 98%, for those patients with primary tumors 99%, and for recurrent patients 87%. The treatment tolerance was excellent in all cases. No severe, early, or late, complications were detected. Conclusions: Radiotherapy is a highly effective treatment of skin carcinomas of the face. Custom-made molds, to be used in conjunction with HDR brachytherapy equipment, make possible a uniform dose distribution, with a sharp dose gradient in the limits of applicators. Custom-made surface molds are easy and safe to use, and they fit very accurately for

  6. Synchronized dynamic dose reconstruction

    International Nuclear Information System (INIS)

    Litzenberg, Dale W.; Hadley, Scott W.; Tyagi, Neelam; Balter, James M.; Ten Haken, Randall K.; Chetty, Indrin J.

    2007-01-01

    Variations in target volume position between and during treatment fractions can lead to measurable differences in the dose distribution delivered to each patient. Current methods to estimate the ongoing cumulative delivered dose distribution make idealized assumptions about individual patient motion based on average motions observed in a population of patients. In the delivery of intensity modulated radiation therapy (IMRT) with a multi-leaf collimator (MLC), errors are introduced in both the implementation and delivery processes. In addition, target motion and MLC motion can lead to dosimetric errors from interplay effects. All of these effects may be of clinical importance. Here we present a method to compute delivered dose distributions for each treatment beam and fraction, which explicitly incorporates synchronized real-time patient motion data and real-time fluence and machine configuration data. This synchronized dynamic dose reconstruction method properly accounts for the two primary classes of errors that arise from delivering IMRT with an MLC: (a) Interplay errors between target volume motion and MLC motion, and (b) Implementation errors, such as dropped segments, dose over/under shoot, faulty leaf motors, tongue-and-groove effect, rounded leaf ends, and communications delays. These reconstructed dose fractions can then be combined to produce high-quality determinations of the dose distribution actually received to date, from which individualized adaptive treatment strategies can be determined

  7. Strong relationship between DMS and the solar radiation dose over the global surface ocean.

    Science.gov (United States)

    Vallina, Sergio M; Simó, Rafel

    2007-01-26

    Marine biogenic dimethylsulfide (DMS) is the main natural source of tropospheric sulfur, which may play a key role in cloud formation and albedo over the remote ocean. Through a global data analysis, we found that DMS concentrations are highly positively correlated with the solar radiation dose in the upper mixed layer of the open ocean, irrespective of latitude, plankton biomass, or temperature. This is a necessary condition for the feasibility of a negative feedback in which light-attenuating DMS emissions are in turn driven by the light dose received by the pelagic ecosystem.

  8. Calculated radiation doses from radionuclides brought to the surface if future drilling intercepts the WIPP repository and pressurized brine

    International Nuclear Information System (INIS)

    Channell, J.K.

    1982-01-01

    This report describes a scenario in which an exploratory borehole connects an underlying brine reservoir with the repository and results in saturation of the waste storage area. A subsequent borehole brings portions of this radionuclide contaminated brine to the surface. Radiation odses are calculated for time periods of 125, 400, and 1000 years after repository closing for the following: (1) external radiation doses for workers at the borehole location; (2) inhalation doses for workers at the borehole location; (3) external and inhalation doses for a resident located 360 meters downwind; (4) ingestion doses for the downwind resident from locally grown produce, milk, and meat; and (5) population doses from inhalation within a 50-mile radius. The probability of the various calculated doses occurring was estimated. Probability was included in the report because of a belief that probability considerations are useful in evaluating the acceptability of unlikely events and to encourage others to provide a more detailed evaluation using more sophisticated methodology. Since the probabilities presented in this report were calculated using a simple methodology, with some parameter values chosen arbitrarily, they should be considered as approximate examples, not accurate numbers. The reasonableness of the scenario and the significance of the results are also discussed

  9. Low doses effects

    International Nuclear Information System (INIS)

    Tubiana, M.

    1997-01-01

    In this article is asked the question about a possible carcinogens effect of low dose irradiation. With epidemiological data, knowledge about the carcinogenesis, the professor Tubiana explains that in spite of experiments made on thousand or hundred of thousands animals it has not been possible to bring to the fore a carcinogens effect for low doses and then it is not reasonable to believe and let the population believe that low dose irradiation could lead to an increase of neoplasms and from this point of view any hardening of radiation protection standards could in fact, increase anguish about ionizing radiations. (N.C.)

  10. Dose/dose-rate responses of shrimp larvae to UV-B radiation

    International Nuclear Information System (INIS)

    Damkaer, D.M.

    1981-01-01

    Previous work indicated dose-rate thresholds in the effects of UV-B on the near-surface larvae of three shrimp species. Additional observations suggest that the total dose response varies with dose-rate. Below 0.002 Wm -2 sub([DNA]) irradiance no significant effect is noted in activity, development, or survival. Beyond that dose-rate threshold, shrimp larvae are significantly affected if the total dose exceeds about 85 Jm -2 sub([DNA]). Predictions cannot be made without both the dose-rate and the dose. These dose/dose-rate thresholds are compared to four-year mean dose/dose-rate solar UV-B irradiances at the experimental site, measured at the surface and calculated for 1 m depth. The probability that the shrimp larvae would receive lethal irradiance is low for the first half of the season of surface occurrence, even with a 44% increase in damaging UV radiation. (orig.)

  11. Doses from radioactive methane

    International Nuclear Information System (INIS)

    Phipps, A.W.; Kendall, G.M.; Fell, T.P.; Harrison, J.D.

    1990-01-01

    A possible radiation hazard arises from exposure to methane labelled with either a 3 H or a 14 C nuclide. This radioactive methane could be released from a variety of sources, e.g. land burial sites containing radioactive waste. Standard assumptions adopted for vapours would not apply to an inert alkane like methane. This paper discusses mechanisms by which radioactive methane would irradiate tissues and provides estimates of doses. Data on skin thickness and metabolism of methane are discussed with reference to these mechanisms. It is found that doses are dominated by dose from the small fraction of methane which is inhaled and metabolised. This component of dose has been calculated under rather conservative assumptions. (author)

  12. Controllable dose; Dosis controlable

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J T; Anaya M, R A [ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2004-07-01

    With the purpose of eliminating the controversy about the lineal hypothesis without threshold which found the systems of dose limitation of the recommendations of ICRP 26 and 60, at the end of last decade R. Clarke president of the ICRP proposed the concept of Controllable Dose: as the dose or dose sum that an individual receives from a particular source which can be reasonably controllable by means of any means; said concept proposes a change in the philosophy of the radiological protection of its concern by social approaches to an individual focus. In this work a panorama of the foundations is presented, convenient and inconveniences that this proposal has loosened in the international community of the radiological protection, with the purpose of to familiarize to our Mexican community in radiological protection with these new concepts. (Author)

  13. Acetaminophen dosing for children

    Science.gov (United States)

    ... your child, call your provider. Proper Dosing of Suppositories If your child is vomiting or will not take oral medicine, you can use suppositories. Suppositories are placed in the anus to deliver ...

  14. Radiation dose electrophysiology procedures

    International Nuclear Information System (INIS)

    Hernandez-Armas, J.; Rodriguez, A.; Catalan, A.; Hernandez Armas, O.; Luque Japon, L.; Moral, S.; Barroso, L.; Rfuez-Hdez, R.

    2006-01-01

    The aim of this paper has been to measure and analyse some of the parameters which are directly related with the doses given to patients in two electrophysiology procedures: diagnosis and ablation with radiofrequency. 16 patients were considered in this study. 13 them had an ablation with radiofrequency at the Unit of Electrophysiology at the University Hospital of the Canaries, La Laguna., Tenerife. The results of skin doses, in the ablation cases, were higher than 2 Gy (threshold of some deterministic effects). The average value was 1.1 Gy. The personal doses, measured under the lead apron, for physician and nurses were 4 and 3 micro Sievert. These results emphasised the necessity of radiation protection measures in order to reduce, ad much as possible, the doses to patients. (Author)

  15. Maximum permissible dose

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    This chapter presents a historic overview of the establishment of radiation guidelines by various national and international agencies. The use of maximum permissible dose and maximum permissible body burden limits to derive working standards is discussed

  16. Irradiation dose of cosmonauts

    International Nuclear Information System (INIS)

    Makra, Zs.

    1978-01-01

    The results obtained by determining the irradiation dose during the spaceflights of Apollo as well as the Sojouz-3 and Sojouz-9 spacecrafts have been compared in the form of tables. In case of Apollo astronauts the irradiation dose was determined by two methods and its sources were also pointed out, in tables. During Sojouz spacetravels the cosmonauts were exposed to a negligible dose. In spite of this fact the radiation danger is considerable. The small irradiation doses noticed so far are due to the fact that during the spaceflights there was no big proturberance. However, during the future long-range spacetravels a better radiation shielding than the one used up to now will be necessary. (P.J.)

  17. Ibuprofen dosing for children

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000772.htm Ibuprofen dosing for children To use the sharing features ... much of this medicine can be harmful. How Ibuprofen can Help Your Child Ibuprofen is a type ...

  18. Evaluation of dose to skin surface contamination in the factory Juzbado of fuel elements

    International Nuclear Information System (INIS)

    Ortiz Trujillo, D.; Agustin Perez Fonseca, A.; Alejandro Fuentes, A.

    2013-01-01

    The aim of this work is previously set a simple calculation methodology applicable to the boundary conditions surrounding the environment where skin contamination may have occurred so that you can evaluate in a simple and fast way the dose that the worker is receiving while enduring such pollution. (Author)

  19. Effects of low doses

    International Nuclear Information System (INIS)

    Le Guen, B.

    2001-01-01

    Actually, even though it is comfortable for the risk management, the hypothesis of the dose-effect relationship linearity is not confirmed for any model. In particular, in the area of low dose rate delivered by low let emitters. this hypothesis is debated at the light of recent observations, notably these ones relative to the mechanisms leading to genetic instability and induction eventuality of DNA repair. The problem of strong let emitters is still to solve. (N.C.)

  20. Gonadal doses from radiotherapy

    International Nuclear Information System (INIS)

    Solomon, S.B.; Morris, N.D.

    1980-06-01

    The method of calculation of gonadal doses arising from different radiotherapeutic procedures is described. The measurement of scatter factors to the gonads from superficial and deep therapy is detailed and the analytic fits to the experimental data, as a function of field position, field size and beam energy are given. The data used to calculate the gonadal doses from treatments using linear accelerators, teletherapy and sealed sources are described and the analytic fits to the data given

  1. Calculation of dose conversion factors for doses in the fingernails to organ doses at external gamma irradiation in air

    International Nuclear Information System (INIS)

    Khailov, A.M.; Ivannikov, A.I.; Skvortsov, V.G.; Stepanenko, V.F.; Orlenko, S.P.; Flood, A.B.; Williams, B.B.; Swartz, H.M.

    2015-01-01

    Absorbed doses to fingernails and organs were calculated for a set of homogenous external gamma-ray irradiation geometries in air. The doses were obtained by stochastic modeling of the ionizing particle transport (Monte Carlo method) for a mathematical human phantom with arms and hands placed loosely along the sides of the body. The resulting dose conversion factors for absorbed doses in fingernails can be used to assess the dose distribution and magnitude in practical dose reconstruction problems. For purposes of estimating dose in a large population exposed to radiation in order to triage people for treatment of acute radiation syndrome, the calculated data for a range of energies having a width of from 0.05 to 3.5 MeV were used to convert absorbed doses in fingernails to corresponding doses in organs and the whole body as well as the effective dose. Doses were assessed based on assumed rates of radioactive fallout at different time periods following a nuclear explosion. - Highlights: • Elemental composition and density of nails were determined. • MIRD-type mathematical human phantom with arms and hands was created. • Organ doses and doses to nails were calculated for external photon exposure in air. • Effective dose and nail doses values are close for rotational and soil surface exposures.

  2. Hanford Environmental Dose Reconstruction Project

    International Nuclear Information System (INIS)

    McMakin, A.H.; Cannon, S.D.; Finch, S.M.

    1992-07-01

    The objective of the Hanford Environmental Dose Reconstruction (HEDR) Project is to estimate the radiation doses that individuals and populations could have received from nuclear operations at Hanford since 1944. The TSP consists of experts in environmental pathways, epidemiology, surface-water transport, ground-water transport, statistics, demography, agriculture, meteorology, nuclear engineering, radiation dosimetry, and cultural anthropology. Included are appointed technical members representing the states of Oregon, Washington, and Idaho, a representative of Native American tribes, and an individual representing the public. The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed from release to impact on humans (dose estimates): Source terms, environmental transport, environmental monitoring data, demography, food consumption, and agriculture, and environmental pathways and dose estimates. Progress is discussed

  3. Characteristic evaluation of a real-time silicon dosimeter and measurement of entrance surface dose at radiography

    International Nuclear Information System (INIS)

    Fujibuchi, Toshiou; Kato, Hideyuki; Hashimoto, Masatoshi; Abe, Yukinao; Kikawa, Takashi

    2006-01-01

    It is important to grasp how much radiation exposure has occurred through radiation diagnosis, in respect to patient explanations and radiation protection. In this examination, we used a patient skin dosimeter (PSD) that measures entrance surface dose (ESD) in real time using a fluoroscopy procedure. The PSD has the ability to display results beginning at 1 μGy. We focused our attention on the X-ray detectability of the PSD, and performed a representative evaluation with the X-ray equipment. We measured ESD under various radiographic parameters at our facility. Although the measurements were dependent on energy, we were able to measure ESD to within an accuracy of about a 5% error by putting a calibration value on energy. The PSD can measure ESD easily without requiring preparation. It is important to be aware of the exposure dose to the radiation staff, and the PSD is a very effective radiation dose-measuring tool when daily business is active. (author)

  4. Evolution of Entrance Surface Doses and Image Quality in Pediatric Chest Radiographs

    International Nuclear Information System (INIS)

    Campello, A.C.; Marques, D.T.; Medeiros, C.B.; Carvalho, P.P.; Khoury, H.J.; Azevedo, A.C.P.

    2006-01-01

    This work presents the results of a survey about image quality, radiographic techniques and patient doses in a large public hospital located in the city of Recife, Brazil. It was detected that the quality criteria are not fully reached and represent 70% of the agreement with recommendations from the European Community. Concerning the radiographic techniques the kV is in accordance with international recommendations in 90% if the examinations while the exposure time is 72%. The results also show that the dose values change in the range from 0.020 to 0.250 mGy. The variability is mainly caused by the disparity on the radiographic techniques employed in the examinations as well as by the radiographer's expertise. It could be concluded that the ALARA principle is not being applied in the hospital, which becomes a concern in terms of public health. (author)

  5. Superficial dose evaluation of four dose calculation algorithms

    Science.gov (United States)

    Cao, Ying; Yang, Xiaoyu; Yang, Zhen; Qiu, Xiaoping; Lv, Zhiping; Lei, Mingjun; Liu, Gui; Zhang, Zijian; Hu, Yongmei

    2017-08-01

    Accurate superficial dose calculation is of major importance because of the skin toxicity in radiotherapy, especially within the initial 2 mm depth being considered more clinically relevant. The aim of this study is to evaluate superficial dose calculation accuracy of four commonly used algorithms in commercially available treatment planning systems (TPS) by Monte Carlo (MC) simulation and film measurements. The superficial dose in a simple geometrical phantom with size of 30 cm×30 cm×30 cm was calculated by PBC (Pencil Beam Convolution), AAA (Analytical Anisotropic Algorithm), AXB (Acuros XB) in Eclipse system and CCC (Collapsed Cone Convolution) in Raystation system under the conditions of source to surface distance (SSD) of 100 cm and field size (FS) of 10×10 cm2. EGSnrc (BEAMnrc/DOSXYZnrc) program was performed to simulate the central axis dose distribution of Varian Trilogy accelerator, combined with measurements of superficial dose distribution by an extrapolation method of multilayer radiochromic films, to estimate the dose calculation accuracy of four algorithms in the superficial region which was recommended in detail by the ICRU (International Commission on Radiation Units and Measurement) and the ICRP (International Commission on Radiological Protection). In superficial region, good agreement was achieved between MC simulation and film extrapolation method, with the mean differences less than 1%, 2% and 5% for 0°, 30° and 60°, respectively. The relative skin dose errors were 0.84%, 1.88% and 3.90%; the mean dose discrepancies (0°, 30° and 60°) between each of four algorithms and MC simulation were (2.41±1.55%, 3.11±2.40%, and 1.53±1.05%), (3.09±3.00%, 3.10±3.01%, and 3.77±3.59%), (3.16±1.50%, 8.70±2.84%, and 18.20±4.10%) and (14.45±4.66%, 10.74±4.54%, and 3.34±3.26%) for AXB, CCC, AAA and PBC respectively. Monte Carlo simulation verified the feasibility of the superficial dose measurements by multilayer Gafchromic films. And the rank

  6. Results of the study of entrance surface dose from conventional examinations in diagnostic radiology

    International Nuclear Information System (INIS)

    Martinez, A.; Jova, L.; Carrazana, J.; Diaz, E.; Mora, R. de la; Guevara, C.; Fleitas, I.

    2001-01-01

    The wide diffusion of X-ray diagnostic together with the quick development and expansion that has come with experiencing the technology in this practice, has motivated the emission of recommendations in the Basic Safety Standards of the IAEA for the establishment of guidance levels for different radiological examinations in each country that allow the optimization of the medical exposure. Considering the above-mentioned and the existence in Cuba in a great number of conventional X-ray equipment, with an average of over 10 years of use which influences directly on the patient dose, in 1999, an investigation began in the country on the patient exposure in this practice. This work shows the first results of measurements carried out in 9 major hospitals of several provinces of the country. The doses were evaluated in the examinations of lumbar spine AP, lumbar spine LAT, thorax PA, skull AP and skull LAT. The determination of the doses in these examinations was carried out by 'in-vivo' measurements on the patients, placing in the center of the irradiation field TLD of LiF. The distributions obtained in the studies are compared with the guidance levels that is shown in the Basic Safety Standards of the IAEA. (author)

  7. Practical experience of monitoring patient dose

    Energy Technology Data Exchange (ETDEWEB)

    McDonnell, C.; Shrimpton, P. (National Radiological Protection Board, Chilton (United Kingdom)); O' Mahoney, M. (National Radiological Protection Board, Leeds (United Kingdom)); Foster, J. (Nuffield Hospitals, Surbiton (United Kingdom))

    1994-05-01

    NRPB recommends the use of reference dose levels for diagnostic medical exposures as an aid to patient dose reduction, but is this approach effective This article describes the broadly encouraging experiences of one large group of hospitals in carrying out measurements of entrance surface dose on patients undergoing some common types of x-ray examination. (author).

  8. Assessment of internal doses

    CERN Document Server

    Rahola, T; Falk, R; Isaksson, M; Skuterud, L

    2002-01-01

    There is a definite need for training in dose calculation. Our first course was successful and was followed by a second, both courses were fully booked. An example of new tools for software products for bioassay analysis and internal dose assessment is the Integrated Modules for Bioassay Analysis (IMBA) were demonstrated at the second course. This suite of quality assured code modules have been adopted in the UK as the standard for regulatory assessment purposes. The intercomparison measurements are an important part of the Quality Assurance work. In what is known as the sup O utside workers ' directive it is stated that the internal dose measurements shall be included in the European Unions supervision system for radiation protection. The emergency preparedness regarding internal contamination was much improved by the training with and calibration of handheld instruments from participants' laboratories. More improvement will be gained with the handbook giving practical instructions on what to do in case of e...

  9. Mean inactivation dose (D)

    International Nuclear Information System (INIS)

    Vijayakumar, S.; Ng, T.C.; Raudkivi, U.; Meaney, T.J.

    1990-01-01

    By predicting treatment outcome to radiotherapy from in vitro radiobiological parameters, not only individual patient treatments can be tailored, but also new promising treatment protocols can be tried in patients in whom unfavorable outcome is predicted. In this respect, choosing the right parameter can be very important. Unlike D 0 and N which provide information of the distal part of the survival curve, mean inactivation dose (D) estimates overall radiosensitivity. However, the parameters reflecting the response at the clinically relevant low-dose region are neglected in the literature. In a literature survey of 98 papers in which survival curves or D 0 /N were used, only in 2 D was used. In 21 papers the D 0 /n values were important in drawing conclusions. By calculating D in 3 of these 21 papers, we show that the conclusion drawn may be altered with the use of D. The importance of ''low-dose-region-parameters'' is reviewed. (orig.)

  10. Dose Reduction Techniques

    International Nuclear Information System (INIS)

    WAGGONER, L.O.

    2000-01-01

    As radiation safety specialists, one of the things we are required to do is evaluate tools, equipment, materials and work practices and decide whether the use of these products or work practices will reduce radiation dose or risk to the environment. There is a tendency for many workers that work with radioactive material to accomplish radiological work the same way they have always done it rather than look for new technology or change their work practices. New technology is being developed all the time that can make radiological work easier and result in less radiation dose to the worker or reduce the possibility that contamination will be spread to the environment. As we discuss the various tools and techniques that reduce radiation dose, keep in mind that the radiological controls should be reasonable. We can not always get the dose to zero, so we must try to accomplish the work efficiently and cost-effectively. There are times we may have to accept there is only so much you can do. The goal is to do the smart things that protect the worker but do not hinder him while the task is being accomplished. In addition, we should not demand that large amounts of money be spent for equipment that has marginal value in order to save a few millirem. We have broken the handout into sections that should simplify the presentation. Time, distance, shielding, and source reduction are methods used to reduce dose and are covered in Part I on work execution. We then look at operational considerations, radiological design parameters, and discuss the characteristics of personnel who deal with ALARA. This handout should give you an overview of what it takes to have an effective dose reduction program

  11. CT dose management

    International Nuclear Information System (INIS)

    Zasheva, Ts.; Georgiev, E.; Kirova, G.

    2013-01-01

    Full text: Introduction: In recent decades Computed Tomography established itself as one of the most common study with a very wide range of applications and techniques of scanning. Best diagnostic value of the method resist to the risks of ionizing radiation, as statistics show that CT is one of the main sources of continuously increasing dose to the population. What you will learn: The physical parameters of the X-ray tube and the principles of image reconstruction; The relationship between variables parameters and the received dose; The ratio between the force and voltage of the current to the image quality, Influence of the used contrast medium to the physical properties of the image, The ratio of patient BMI to image processing, Effective use of knowledge for the optimal CT protocol. Discussions: The goal to reduce the dose received by the patient during a CT scan while keeping the diagnostic quality of the image puts to the test as handset X-ray producers and technicians who need to master the technique of study protocol forming as well as to balance the harm - benefit ratio. Among the most popular techniques are these of dose modulation, low-dose computed tomography at the expense of a reduction of the current or voltage intensity, and control of the number of post-processing algorithms for the image reconstruction. Conclusion: The training of radiologists and X-ray technicians plays a major role in optimizing of technical parameters in view of the reduction of the dose for the patient, while maintaining the diagnostic quality of the image

  12. Dose Reduction Techniques

    Energy Technology Data Exchange (ETDEWEB)

    WAGGONER, L.O.

    2000-05-16

    As radiation safety specialists, one of the things we are required to do is evaluate tools, equipment, materials and work practices and decide whether the use of these products or work practices will reduce radiation dose or risk to the environment. There is a tendency for many workers that work with radioactive material to accomplish radiological work the same way they have always done it rather than look for new technology or change their work practices. New technology is being developed all the time that can make radiological work easier and result in less radiation dose to the worker or reduce the possibility that contamination will be spread to the environment. As we discuss the various tools and techniques that reduce radiation dose, keep in mind that the radiological controls should be reasonable. We can not always get the dose to zero, so we must try to accomplish the work efficiently and cost-effectively. There are times we may have to accept there is only so much you can do. The goal is to do the smart things that protect the worker but do not hinder him while the task is being accomplished. In addition, we should not demand that large amounts of money be spent for equipment that has marginal value in order to save a few millirem. We have broken the handout into sections that should simplify the presentation. Time, distance, shielding, and source reduction are methods used to reduce dose and are covered in Part I on work execution. We then look at operational considerations, radiological design parameters, and discuss the characteristics of personnel who deal with ALARA. This handout should give you an overview of what it takes to have an effective dose reduction program.

  13. Dose Distribution of Gamma Irradiators

    International Nuclear Information System (INIS)

    Park, Seung Woo; Shin, Sang Hun; Son, Ki Hong; Lee, Chang Yeol; Kim, Kum Bae; Jung, Hai Jo; Ji, Young Hoon

    2010-01-01

    Gamma irradiator using Cs-137 have been widely utilized to the irradiation of cell, blood, and animal, and the dose measurement and education. The Gamma cell 3000 Elan (Nordion International, Kanata, Ontario, Canada) irradiator was installed in 2003 with Cs-137 and dose rate of 3.2 Gy/min. And the BioBeam 8000 (Gamma-Service Medical GmbH, Leipzig, Germany) irradiator was installed in 2008 with Cs-137 and dose rate of 3.5 Gy/min. Our purpose was to evaluate the practical dosimetric problems associated with inhomogeneous dose distribution within the irradiated volume in open air state using glass dosimeter and Gafchromic EBT film dosimeter for routine Gamma irradiator dosimetry applications at the KIRAMS and the measurements were compared with each other. In addition, an user guideline for useful utilization of the device based on practical dosimetry will be prepared. The measurement results of uniformity of delivered dose within the device showed variation more than 14% between middle point and the lowest position at central axis. Therefore, to maintain dose variation within 10%, the criteria of useful dose distribution, for research radiation effects, the irradiated specimen located at central axis of the container should be placed within 30 mm from top and bottom surface, respectively. In addition, for measurements using the film, the variations of dose distribution were more then 50% for the case of less than 10 second irradiation, mostly within 20% for the case of more than 20 second irradiation, respectively. Therefore, the irradiation experiments using the BioBeam 8000 irradiator are recommended to be used for specimen required at least more than 20 second irradiation time.

  14. TLD estimation of absorbed dose for 131I on the surface of biological organs of REMCAL phantom

    International Nuclear Information System (INIS)

    Tandon, Pankaj; Gaur, P.K.; Bhatt, B.C.; Soni, P.S.

    2001-01-01

    In nuclear medicine, the accuracy of absorbed dose of an internally distributed radiopharmaceuticals estimated by the MIRD (medical internal radiation dose) method depends on the cumulated activity of the source organs and their mass. The usual method for obtaining the cumulated activities are: 1) direct measurements by a) positron emission tomography (PET) and b) single photon emission computed tomography (SPECT) 2) extrapolation from animal data and 3) calculations based on the mathematical biokinetic model. Among these methods, extrapolation of animal data to humans includes inevitable inaccuracy due to large interspecies metabolic differences with regard to the administered radiochemical. Biokinetic modeling requires adequate knowledge of various kinetic parameters, which is based on some biological assumptions. Direct measurements can provide cumulated distributions with fewer biological assumptions. But direct measurements of PET/SPECT are difficult to perform routinely. A method has been developed to obtain the surface dose of different biological organs by using TLDs. Here, a number of TLDs are placed just above the surface of the biological organs of the REMCAL Alderson human phantom filled with water. Firstly, investigation of the accuracy of this method by calibration studies using the said phantom, which is having the entire biological organ intact and simulate the organs as human body is done. These organs are filled with the known activity of the radioisotope. In the present study, estimation of radiation dose received by fifteen different target organs, when the known activity was filled in the three major organs of interest was carried out

  15. The Dose Assessment in the Vault Test Case of Near-Surface Disposal Facility for Drinking Water Scenario

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hyoung; Choi, Byung Seon; Moon, Jei Kwon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Park, Jae Woo [Jeju National University, Jeju (Korea, Republic of)

    2012-05-15

    It is generally accepted that the radionuclides contained in the radioactive wastes will be eventually released and these will be transported to the accessible environment (near-field, far-field, biosphere). Therefore, the long-term safety assessment of near-surface radioactive waste disposal should be required by modeling the expected release of radionuclides from the repository, far-field area, and biosphere. Finally, the effective dose rate should be estimated through the released radionuclides. In this study, the radiological dose was evaluated for the reference near-surface radioactive waste disposal facility in Vaalputs, South Africa, which has been selected as a part of IAEA coordinated research program on improvement of safety assessment methodologies(ISAM). The assessment of radiological dose was performed for drinking water scenario from a well. The release and transport of radionuclides in disposal system were simulated by GoldSim. This approach suggested the time variation of effective dose over long-term period. And the results from this approach were compared with another approach method for the same facility and scenario

  16. The Dose Assessment in the Vault Test Case of Near-Surface Disposal Facility for Drinking Water Scenario

    International Nuclear Information System (INIS)

    Kim, Tae Hyoung; Choi, Byung Seon; Moon, Jei Kwon; Park, Jae Woo

    2012-01-01

    It is generally accepted that the radionuclides contained in the radioactive wastes will be eventually released and these will be transported to the accessible environment (near-field, far-field, biosphere). Therefore, the long-term safety assessment of near-surface radioactive waste disposal should be required by modeling the expected release of radionuclides from the repository, far-field area, and biosphere. Finally, the effective dose rate should be estimated through the released radionuclides. In this study, the radiological dose was evaluated for the reference near-surface radioactive waste disposal facility in Vaalputs, South Africa, which has been selected as a part of IAEA coordinated research program on improvement of safety assessment methodologies(ISAM). The assessment of radiological dose was performed for drinking water scenario from a well. The release and transport of radionuclides in disposal system were simulated by GoldSim. This approach suggested the time variation of effective dose over long-term period. And the results from this approach were compared with another approach method for the same facility and scenario

  17. Radioactive cloud dose calculations

    International Nuclear Information System (INIS)

    Healy, J.W.

    1984-01-01

    Radiological dosage principles, as well as methods for calculating external and internal dose rates, following dispersion and deposition of radioactive materials in the atmosphere are described. Emphasis has been placed on analytical solutions that are appropriate for hand calculations. In addition, the methods for calculating dose rates from ingestion are discussed. A brief description of several computer programs are included for information on radionuclides. There has been no attempt to be comprehensive, and only a sampling of programs has been selected to illustrate the variety available

  18. Evaluation of the dose uniformity for double-plane high dose rate interstitial breast implants with the use of dose reference points and dose non-uniformity ratio

    International Nuclear Information System (INIS)

    MAjor, T.; Polgar, C.; Somogyi, A.; Nemeth, G.

    2000-01-01

    This study investigated the influence of dwell time optimizations on dose uniformity characterized by dose values in dose points and dose non-uniformity ratio (DNR) and analyzed which implant parameters have influence on the DNR. Double-plane breast implants with catheters arranged in triangular pattern were used for the calculations. At a typical breast implant, dose values in dose reference points inside the target volume and volumes enclosed by given isodose surfaces were calculated and compared for non-optimized and optimized implants. The same 6-cm treatment length was used for the comparisons. Using different optimizations plots of dose non-uniformity ratio as a function of catheter separation, source step size, number of catheters, length of active sections were drawn and the minimum DNR values were determined. Optimization resulted in less variation in dose values over dose points through the whole volume and in the central plane only compared to the non-optimized case. At implant configurations consisting of seven catheters with 15-mm separation, 5-mm source step size and various active lengths adapted according to the type of optimization, the no optimization, geometrical (volume mode) and dose point (on dose points and geometry) optimization resulted in similar treatment volumes, but an increased high dose volume was observed due to the optimization. The dose non-uniformity ratio always had the minimum at average dose over dose normalization points, defined in the midpoints between the catheters through the implant volume. The minimum value of DNR depended on catheter separation, source step size, active length and number of catheters. The optimization had only a small influence on DNR. In addition to the reference points in the central plane only, dose points positioned in the whole implant volume can be used for evaluating the dose uniformity of interstitial implants. The dose optimization increases not only the dose uniformity within the implant but

  19. Effect of Increasing Doses of γ-Radiation on Bone Marrow Stromal Cells Grown on Smooth and Rough Titanium Surfaces

    Directory of Open Access Journals (Sweden)

    Bo Huang

    2015-01-01

    Full Text Available Radiation therapy for oral and maxillofacial tumors could damage bone marrow stromal cells (BMSCs in jaw, which caused dental implant failure. However, how radiation affects BMSCs on SLA (sandblasted with large-grits, acid-etched surfaces is still unknown. The aim of this study was to investigate effect of different dose of γ-radiation on BMSCs on SLA and PT (polished titanium surfaces. Rat BMSCs were radiated with 2, 4, and 8 Gy γ-radiation and then seeded on both surfaces. Cell adhesion, spreading, and proliferation were tested. The osteogenesis and the adipogenesis ability were examined by Alizarin-Red and Oil-Red staining, respectively. Real-time PCR was performed to detect osteogenic (osteocalcin, OCN; runt-related transcription factor 2, Runx2 and adipogenic (peroxisome proliferator-activated receptor gamma, PPARγ gene expression at days 7 and 14 postirradiation. Results showed that γ-radiation reduced cell proliferation, adhesion, spreading, and osteogenic differentiation. 2 Gy radiation promoted adipogenic differentiation, but it was significantly decreased when dosage reached 4 Gy. In conclusion, results suggest that γ-radiation influenced BMSCs behaviors in a dosage-dependent manner except adipogenic differentiation, low dose promoted it, and high dose inhibited it. This effect was influenced by surface characteristics, which may explain the different failure rate of various implants in patients after radiation.

  20. Fertilizer micro-dosing

    International Development Research Centre (IDRC) Digital Library (Canada)

    Localized application of small quantities of fertilizer (micro-dosing), combined with improved planting pits for rainwater harvesting, has generated greater profits and food security for women farmers in the Sahel. • Women are 25% more likely to use combined applications, and have expanded areas of food crops (cowpea,.

  1. Weldon Spring dose calculations

    International Nuclear Information System (INIS)

    Dickson, H.W.; Hill, G.S.; Perdue, P.T.

    1978-09-01

    In response to a request by the Oak Ridge Operations (ORO) Office of the Department of Energy (DOE) for assistance to the Department of the Army (DA) on the decommissioning of the Weldon Spring Chemical Plant, the Health and Safety Research Division of the Oak Ridge National Laboratory (ORNL) performed limited dose assessment calculations for that site. Based upon radiological measurements from a number of soil samples analyzed by ORNL and from previously acquired radiological data for the Weldon Spring site, source terms were derived to calculate radiation doses for three specific site scenarios. These three hypothetical scenarios are: a wildlife refuge for hunting, fishing, and general outdoor recreation; a school with 40 hr per week occupancy by students and a custodian; and a truck farm producing fruits, vegetables, meat, and dairy products which may be consumed on site. Radiation doses are reported for each of these scenarios both for measured uranium daughter equilibrium ratios and for assumed secular equilibrium. Doses are lower for the nonequilibrium case

  2. Low dose epidemiologic studies

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    In this chapter the BEIR committee has reviewed low-dose irradiation studies since the BEIR III report. They have considered the carcinogenic effectiveness of low-LET in populations exposed to radiation from a number of different sources: diagnostic radiography; fallout from nuclear weapons testing; nuclear installations; radiation in the workplace and high levels of natural background radiation

  3. Radiation doses to Finns

    International Nuclear Information System (INIS)

    Rantalainen, L.

    1996-01-01

    The estimated annual radiation doses to Finns have been reduced in the recent years without any change in the actual radiation environment. This is because the radiation types have been changed. The risk factors will probably be changed again in the future, because recent studies show discrepancies in the neutron dosimetry concerning the city of Hiroshima. Neutron dosimetry discrepancy has been found between the predicted and estimated neutron radiation. The prediction of neutron radiation is calculated by Monte Carlo simulations, which have also been used when designing recommendations for the limits of radiation doses (ICRP60). Estimation of the neutron radiation is made on the basis of measured neutron activation of materials in the city. The estimated neutron dose beyond 1 km is two to ten, or more, times as high as the predicted dose. This discrepancy is important, because the most relevant distances with respect to radiation risk evaluation are between 1 and 2 km. Because of this discrepancy, the present radiation risk factors for gamma and neutron radiation, which rely on the Monte Carlo calculations, are false, too. The recommendations of ICRP60 have been adopted in a few countries, including Finland, and they affect the planned common limits of the EU. It is questionable whether happiness is increased by adopting false limits, even if they are common. (orig.) (2 figs., 1 tab.)

  4. Dose Reduction Techniques

    CERN Document Server

    Waggoner, L O

    2000-01-01

    As radiation safety specialists, one of the things we are required to do is evaluate tools, equipment, materials and work practices and decide whether the use of these products or work practices will reduce radiation dose or risk to the environment. There is a tendency for many workers that work with radioactive material to accomplish radiological work the same way they have always done it rather than look for new technology or change their work practices. New technology is being developed all the time that can make radiological work easier and result in less radiation dose to the worker or reduce the possibility that contamination will be spread to the environment. As we discuss the various tools and techniques that reduce radiation dose, keep in mind that the radiological controls should be reasonable. We can not always get the dose to zero, so we must try to accomplish the work efficiently and cost-effectively. There are times we may have to accept there is only so much you can do. The goal is to do the sm...

  5. Dose tracking and dose auditing in a comprehensive computed tomography dose-reduction program.

    Science.gov (United States)

    Duong, Phuong-Anh; Little, Brent P

    2014-08-01

    Implementation of a comprehensive computed tomography (CT) radiation dose-reduction program is a complex undertaking, requiring an assessment of baseline doses, an understanding of dose-saving techniques, and an ongoing appraisal of results. We describe the role of dose tracking in planning and executing a dose-reduction program and discuss the use of the American College of Radiology CT Dose Index Registry at our institution. We review the basics of dose-related CT scan parameters, the components of the dose report, and the dose-reduction techniques, showing how an understanding of each technique is important in effective auditing of "outlier" doses identified by dose tracking. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. When is a dose not a dose?

    International Nuclear Information System (INIS)

    Bond, V.P.

    1991-01-01

    Although an enormous amount of progress has been made in the fields of radiation protection and risk assessment, a number of significant problems remain. The one problem which transcends all the rest, and which has been subject to considerable misunderstanding, involves what has come to be known as the 'linear non-threshold hypothesis', or 'linear hypothesis'. Particularly troublesome has been the interpretation that any amount of radiation can cause an increase in the excess incidence of cancer. The linear hypothesis has dominated radiation protection philosophy for more than three decades, with enormous financial, societal and political impacts and has engendered an almost morbid fear of low-level exposure to ionizing radiation in large segments of the population. This document presents a different interpretation of the linear hypothesis. The basis for this view lies in the evolution of dose-response functions, particularly with respect to their use initially in the context of early acute effects, and then for the late effects, carcinogenesis and mutagenesis. 11 refs., 4 figs

  7. Evaluation of skin surface dose for head and neck cancer patients treated with intensity-modulated radiation therapy using in vivo dosimetry

    International Nuclear Information System (INIS)

    Kim, Yeon Sil; Lee, Dong Soo; Yoo, Mi Na; Hong, Joo Young; Yoon, Se Chul; Jang, Hong Suk

    2011-01-01

    Use of intensity-modulated radiation therapy (IMRT) for head and neck cancer is gradually increasing, because it could facilitate more sophsticated treatment of target volumes and reduction of acute and late sequelae. However, theoretically, there is a potential risk of increased skin surface dose resulting from multiple obliquity effects caused by multiple tangential beams. Moreover, we sometimes confronted with more skin reactions in the patients treated with IMRT than conventional techniques. In this study, we evaluated skin surface dose adjacent to the target volumes to verify whether the use of IMRT would increase the skin dose more than we predicted. This study had shown that the use of IMRT did not increase the skin surface hot point dose. The measured skin surface dose was 20 to 40 percent of the adjacent target prescription dose, and was within acceptable dose range. Our study had some limitations with small number of experimental patients and methodological problems. Potential risk of increasing skin dose with bolus effect of aquaplaster should be examined in the future trials. In addition, the accurate set-up verification should be maintained because of steep dose gradient between skin surface and target volumes within a short distance in the head and neck cancer patients.

  8. Dose specification for radiation therapy: dose to water or dose to medium?

    International Nuclear Information System (INIS)

    Ma, C-M; Li Jinsheng

    2011-01-01

    The Monte Carlo method enables accurate dose calculation for radiation therapy treatment planning and has been implemented in some commercial treatment planning systems. Unlike conventional dose calculation algorithms that provide patient dose information in terms of dose to water with variable electron density, the Monte Carlo method calculates the energy deposition in different media and expresses dose to a medium. This paper discusses the differences in dose calculated using water with different electron densities and that calculated for different biological media and the clinical issues on dose specification including dose prescription and plan evaluation using dose to water and dose to medium. We will demonstrate that conventional photon dose calculation algorithms compute doses similar to those simulated by Monte Carlo using water with different electron densities, which are close (<4% differences) to doses to media but significantly different (up to 11%) from doses to water converted from doses to media following American Association of Physicists in Medicine (AAPM) Task Group 105 recommendations. Our results suggest that for consistency with previous radiation therapy experience Monte Carlo photon algorithms report dose to medium for radiotherapy dose prescription, treatment plan evaluation and treatment outcome analysis.

  9. Effect of low dose of Vitex agnus castus on volume and surface area of oocyte in mice

    OpenAIRE

    HAMIDIAN, Gholamreza; YAHYAVI, Fariba

    2014-01-01

    Vitex agnus-castus L. (VAC) is a deciduous shrub that is native to Mediterranean, Europe and Central Asia. VAC extract has been used traditionally in the treatment of menstrual disorders (amenorrhoea, dysmenorrhoea), premenstrual syndrome (PMS), corpus luteum insufficiency, uterine bleeding, fibroid cysts, infertility, acne, menopause, disrupted lactation and hyperprolactinaemia. This study was aimed to evaluate the effects of low dose of VAC essential oil on volume and surface area of oocyte...

  10. Tissue dose in thorotrast patients

    International Nuclear Information System (INIS)

    Kaul, A.; Noffz, W.

    1978-01-01

    Absorbed doses to the liver, spleen, red marrow, lungs, kidneys, and to various parts of bone tissue were calculated for long-term burdens of intravascularly injected Thorotrast. The estimates were performed for typical injection levels of 10, 30, 50 and 100 ml, based upon best estimates of 232 Th tissue distribution, and steady state activity ratios between the subsequent daughters. Correcting for the α-particle self absorption within Thorotrast aggregates, the mean α-dose to a standard 70-kg man at 30 yr after the injection 0f 25 ml of Thorotrast is 750 rad to the liver, 2100 rad to the spleen, 270 rad to the red marrow, 60-620 rad in various parts of the lung, and 13 rad to the kidneys. Dose rates to various parts of bone tissue (bone surface, compact, and cancellous bone) were estimated by applying the ICRP model on alkaline earth metabolism to the continuous translocation of thorium daughters to bone and to the formation of thorium daughters by decay within bone tissue. The average dose to calcified bone from translocated 224 Ra with its daughters is 18 rad at 30 yr after the injection of 25 ml of Thorotrast. Considering the Spiess-Mays risk coefficient of 0.9-1.7% bone sarcoma/ 100 rad of average skeletal dose from 224 Ra and its daughters, the induction of 1.6-3.1 bone sarcomas per 1000 Thorotrast patients is predicted. (author)

  11. Tumor significant dose

    International Nuclear Information System (INIS)

    Supe, S.J.; Nagalaxmi, K.V.; Meenakshi, L.

    1983-01-01

    In the practice of radiotherapy, various concepts like NSD, CRE, TDF, and BIR are being used to evaluate the biological effectiveness of the treatment schedules on the normal tissues. This has been accepted as the tolerance of the normal tissue is the limiting factor in the treatment of cancers. At present when various schedules are tried, attention is therefore paid to the biological damage of the normal tissues only and it is expected that the damage to the cancerous tissues would be extensive enough to control the cancer. Attempt is made in the present work to evaluate the concent of tumor significant dose (TSD) which will represent the damage to the cancerous tissue. Strandquist in the analysis of a large number of cases of squamous cell carcinoma found that for the 5 fraction/week treatment, the total dose required to bring about the same damage for the cancerous tissue is proportional to T/sup -0.22/, where T is the overall time over which the dose is delivered. Using this finding the TSD was defined as DxN/sup -p/xT/sup -q/, where D is the total dose, N the number of fractions, T the overall time p and q are the exponents to be suitably chosen. The values of p and q are adjusted such that p+q< or =0.24, and p varies from 0.0 to 0.24 and q varies from 0.0 to 0.22. Cases of cancer of cervix uteri treated between 1978 and 1980 in the V. N. Cancer Centre, Kuppuswamy Naidu Memorial Hospital, Coimbatore, India were analyzed on the basis of these formulations. These data, coupled with the clinical experience, were used for choice of a formula for the TSD. Further, the dose schedules used in the British Institute of Radiology fraction- ation studies were also used to propose that the tumor significant dose is represented by DxN/sup -0.18/xT/sup -0.06/

  12. [Evaluation of Organ Dose Estimation from Indices of CT Dose Using Dose Index Registry].

    Science.gov (United States)

    Iriuchijima, Akiko; Fukushima, Yasuhiro; Ogura, Akio

    Direct measurement of each patient organ dose from computed tomography (CT) is not possible. Most methods to estimate patient organ dose is using Monte Carlo simulation with dedicated software. However, dedicated software is too expensive for small scale hospitals. Not every hospital can estimate organ dose with dedicated software. The purpose of this study was to evaluate the simple method of organ dose estimation using some common indices of CT dose. The Monte Carlo simulation software Radimetrics (Bayer) was used for calculating organ dose and analysis relationship between indices of CT dose and organ dose. Multidetector CT scanners were compared with those from two manufactures (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare). Using stored patient data from Radimetrics, the relationships between indices of CT dose and organ dose were indicated as each formula for estimating organ dose. The accuracy of estimation method of organ dose was compared with the results of Monte Carlo simulation using the Bland-Altman plots. In the results, SSDE was the feasible index for estimation organ dose in almost organs because it reflected each patient size. The differences of organ dose between estimation and simulation were within 23%. In conclusion, our estimation method of organ dose using indices of CT dose is convenient for clinical with accuracy.

  13. Effects of proton radiation dose, dose rate and dose fractionation on hematopoietic cells in mice

    International Nuclear Information System (INIS)

    Ware, J.H.; Rusek, A.; Sanzari, J.; Avery, S.; Sayers, C.; Krigsfeld, G.; Nuth, M.; Wan, X.S.; Kennedy, A.R.

    2010-01-01

    The present study evaluated the acute effects of radiation dose, dose rate and fractionation as well as the energy of protons in hematopoietic cells of irradiated mice. The mice were irradiated with a single dose of 51.24 MeV protons at a dose of 2 Gy and a dose rate of 0.05-0.07 Gy/min or 1 GeV protons at doses of 0.1, 0.2, 0.5, 1, 1.5 and 2 Gy delivered in a single dose at dose rates of 0.05 or 0.5 Gy/min or in five daily dose fractions at a dose rate of 0.05 Gy/min. Sham-irradiated animals were used as controls. The results demonstrate a dose-dependent loss of white blood cells (WBCs) and lymphocytes by up to 61% and 72%, respectively, in mice irradiated with protons at doses up to 2 Gy. The results also demonstrate that the dose rate, fractionation pattern and energy of the proton radiation did not have significant effects on WBC and lymphocyte counts in the irradiated animals. These results suggest that the acute effects of proton radiation on WBC and lymphocyte counts are determined mainly by the radiation dose, with very little contribution from the dose rate (over the range of dose rates evaluated), fractionation and energy of the protons.

  14. Effects of proton radiation dose, dose rate and dose fractionation on hematopoietic cells in mice.

    Science.gov (United States)

    Ware, J H; Sanzari, J; Avery, S; Sayers, C; Krigsfeld, G; Nuth, M; Wan, X S; Rusek, A; Kennedy, A R

    2010-09-01

    The present study evaluated the acute effects of radiation dose, dose rate and fractionation as well as the energy of protons in hematopoietic cells of irradiated mice. The mice were irradiated with a single dose of 51.24 MeV protons at a dose of 2 Gy and a dose rate of 0.05-0.07 Gy/min or 1 GeV protons at doses of 0.1, 0.2, 0.5, 1, 1.5 and 2 Gy delivered in a single dose at dose rates of 0.05 or 0.5 Gy/min or in five daily dose fractions at a dose rate of 0.05 Gy/min. Sham-irradiated animals were used as controls. The results demonstrate a dose-dependent loss of white blood cells (WBCs) and lymphocytes by up to 61% and 72%, respectively, in mice irradiated with protons at doses up to 2 Gy. The results also demonstrate that the dose rate, fractionation pattern and energy of the proton radiation did not have significant effects on WBC and lymphocyte counts in the irradiated animals. These results suggest that the acute effects of proton radiation on WBC and lymphocyte counts are determined mainly by the radiation dose, with very little contribution from the dose rate (over the range of dose rates evaluated), fractionation and energy of the protons.

  15. Calculation of midplane dose for total body irradiation from entrance and exit dose MOSFET measurements.

    Science.gov (United States)

    Satory, P R

    2012-03-01

    This work is the development of a MOSFET based surface in vivo dosimetry system for total body irradiation patients treated with bilateral extended SSD beams using PMMA missing tissue compensators adjacent to the patient. An empirical formula to calculate midplane dose from MOSFET measured entrance and exit doses has been derived. The dependency of surface dose on the air-gap between the spoiler and the surface was investigated by suspending a spoiler above a water phantom, and taking percentage depth dose measurements (PDD). Exit and entrances doses were measured with MOSFETs in conjunction with midplane doses measured with an ion chamber. The entrance and exit doses were combined using an exponential attenuation formula to give an estimate of midplane dose and were compared to the midplane ion chamber measurement for a range of phantom thicknesses. Having a maximum PDD at the surface simplifies the prediction of midplane dose, which is achieved by ensuring that the air gap between the compensator and the surface is less than 10 cm. The comparison of estimated midplane dose and measured midplane dose showed no dependence on phantom thickness and an average correction factor of 0.88 was found. If the missing tissue compensators are kept within 10 cm of the patient then MOSFET measurements of entrance and exit dose can predict the midplane dose for the patient.

  16. Spiraling contaminant electrons increase doses to surfaces outside the photon beam of an MRI-linac with a perpendicular magnetic field.

    Science.gov (United States)

    Hackett, Sara L; van Asselen, Bram; Wolthaus, Jochem W H; Bluemink, J J; Ishakoglu, Kübra; Kok, Jan G M; Lagendijk, Jan J W; Raaymakers, Bas W

    2018-03-29

    The transverse magnetic field of an MRI-linac sweeps contaminant electrons away from the radiation beam. Films oriented perpendicular to the magnetic field and 5cm from the radiation beam edge show a projection of the divergent beam, indicating that contaminant electrons spiral along magnetic field lines and deposit dose on surfaces outside the primary beam perpendicular to the magnetic field. These spiraling contaminant electrons (SCE) could increase skin doses to protruding regions of the patient along the cranio-caudal axis. This study investigated doses from SCE for an MRI-linac comprising a 7MV linac and a 1.5T MRI scanner. Surface doses to films perpendicular to the magnetic field and 5cm from the radiation beam edge showed increased dose within the projection of the primary beam, whereas films parallel to the magnetic field and 5cm from the beam edge showed no region of increased dose. However, the dose from contaminant electrons is absorbed within a few millimeters. For large fields, the SCE dose is within the same order of magnitude as doses from scattered and leakage photons. Doses for both SCE and scattered photons decrease rapidly with decreasing beam size and increasing distance from the beam edge. © 2018 Institute of Physics and Engineering in Medicine.

  17. Occupational dose assessment and national dose registry system in Iran

    International Nuclear Information System (INIS)

    Jafari-Zadeh, M.; Nazeri, F.; Hosseini-Pooya, S. M.; Taheri, M.; Gheshlaghi, F.; Kardan, M. R.; Babakhani, A.; Rastkhah, N.; Yousefi-Nejad, F.; Darabi, M.; Oruji, T.; Gholamali-Zadeh, Z.; Karimi-Diba, J.; Kazemi-Movahed, A. A.; Dashti-Pour, M. R.; Enferadi, A.; Jahanbakhshian, M. H.; Sadegh-Khani, M. R.

    2011-01-01

    This report presents status of external and internal dose assessment of workers and introducing the structure of National Dose Registry System of Iran (NDRSI). As well as types of individual dosemeters in use, techniques for internal dose assessment are presented. Results obtained from the International Atomic Energy Agency intercomparison programme on measurement of personal dose equivalent H p (10) and consistency of the measured doses with the delivered doses are shown. Also, implementation of dosimetry standards, establishment of quality management system, authorisation and approval procedure of dosimetry service providers are discussed. (authors)

  18. Doses from radiation exposure

    CERN Document Server

    Menzel, H G

    2012-01-01

    Practical implementation of the International Commission on Radiological Protection's (ICRP) system of protection requires the availability of appropriate methods and data. The work of Committee 2 is concerned with the development of reference data and methods for the assessment of internal and external radiation exposure of workers and members of the public. This involves the development of reference biokinetic and dosimetric models, reference anatomical models of the human body, and reference anatomical and physiological data. Following ICRP's 2007 Recommendations, Committee 2 has focused on the provision of new reference dose coefficients for external and internal exposure. As well as specifying changes to the radiation and tissue weighting factors used in the calculation of protection quantities, the 2007 Recommendations introduced the use of reference anatomical phantoms based on medical imaging data, requiring explicit sex averaging of male and female organ-equivalent doses in the calculation of effecti...

  19. Radiation dose rate meter

    International Nuclear Information System (INIS)

    Kronenberg, S.; Siebentritt, C.R.

    1981-01-01

    A combined dose rate meter and charger unit therefor which does not require the use of batteries but on the other hand produces a charging potential by means of a piezoelectric cylinder which is struck by a manually triggered hammer mechanism. A tubular type electrometer is mounted in a portable housing which additionally includes a geiger-muller (Gm) counter tube and electronic circuitry coupled to the electrometer for providing multi-mode operation. In one mode of operation, an rc circuit of predetermined time constant is connected to a storage capacitor which serves as a timed power source for the gm tube, providing a measurement in terms of dose rate which is indicated by the electrometer. In another mode, the electrometer indicates individual counts

  20. Small dose... big poison.

    Science.gov (United States)

    Braitberg, George; Oakley, Ed

    2010-11-01

    It is not possible to identify all toxic substances in a single journal article. However, there are some exposures that in small doses are potentially fatal. Many of these exposures are particularly toxic to children. Using data from poison control centres, it is possible to recognise this group of exposures. This article provides information to assist the general practitioner to identify potential toxic substance exposures in children. In this article the authors report the signs and symptoms of toxic exposures and identify the time of onset. Where clear recommendations on the period of observation and known fatal dose are available, these are provided. We do not discuss management or disposition, and advise readers to contact the Poison Information Service or a toxicologist for this advice.

  1. Radiation dose measurements

    International Nuclear Information System (INIS)

    1960-01-01

    About 200 scientists from 28 countries and 5 international organizations met at a symposium on radiation dosimetry held by the International Atomic Energy Agency in June 1960. The aim of the symposium was not so much the description of a large number of measuring instruments as a discussion of the methods used, with special emphasis on those problems which had become important in the context of recent developments, such as the measurement of mixed or very large doses

  2. Low dose epidemiology

    International Nuclear Information System (INIS)

    Tirmarche, M.; Hubert, P.

    1992-01-01

    Actually, epidemiological studies have to establish if the assessment of cancer risk can be verified at low chronic radiation doses. The population surveillance must be very long, the side effects and cancers of such radiation appearing much later. In France, this epidemiological study on nuclear workers have been decided recently. Before describing the experiment and french projects in epidemiology of nuclear workers, the authors present the main english and american studies

  3. Spatial distribution of tritium in surface water and assessment of ingestion dose

    International Nuclear Information System (INIS)

    Rupali, C.K.; Jha, S.K.; Tripathi, R.M.; Sonali, B.; Reddy, Priyanka

    2014-01-01

    The present study focuses on the distribution of tritium in drinking water samples from Mumbai and other suburban areas. Measurement of tritium in the drinking water was carried out using an ultra-low background LKB Quantulus Spectrometer, model 1220. The concentration of tritium in the drinking water ranged between ≤12.3-19.8TU with a geometric mean of 13.3TU. The observed values doesn't indicate any fresh input of tritium and are well within prescribed limit of 740 Bq/L (approx. 6,271.2 TU) given by USEPA for tritium ingestion through drinking water. The estimated dose due to tritium ingestion through drinking was 0.02 μSv/y which is negligible when compared to the limit of 1000 μSv/y assigned to general public. (author)

  4. Time-dose modifications

    International Nuclear Information System (INIS)

    Kian Ang, K.

    1987-01-01

    Changes in fractionation schedule can be made by various approaches. However, from the first principle, it is anticipated that strategies of hyperfractionation and/or accelerated fractionation offer the most promised in improving the therapeutic ratio. Hyperfractionation is defined as a treatment schedule in which a large number of significantly reduced dose fractions (--1.2 Gy/fraction) is used to give a greater total dose in a conventional overall time period. The results of the pilot studies testing the efficacy of hyperfractionation have been encouraging. The most valid clinical trial of pure hyperfractionation, however, is that conducted by the EORTC. This study compared 70 Gy in 35 fractions or 80.5 Gy in 70 fractions over 7 weeks in the treatment of patients with oropharyngeal carcinomas. The local tumor control was significantly improved in the hyperfractionated arm without increasing the morbidity. Accelerated fractionation is defined as a schedule in which the overall time of treatment is reduced without significant changes in the total dose and fraction size. The strategy has been used to treat patients with malignant gliomas, melanomas and Head and Neck cancers. The data in Head and Neck Cancers seem to be promising

  5. Dose calculation for electrons

    International Nuclear Information System (INIS)

    Hirayama, Hideo

    1995-01-01

    The joint working group of ICRP/ICRU is advancing the works of reviewing the ICRP publication 51 by investigating the data related to radiation protection. In order to introduce the 1990 recommendation, it has been demanded to carry out calculation for neutrons, photons and electrons. As for electrons, EURADOS WG4 (Numerical Dosimetry) rearranged the data to be calculated at the meeting held in PTB Braunschweig in June, 1992, and the question and request were presented by Dr. J.L. Chartier, the responsible person, to the researchers who are likely to undertake electron transport Monte Carlo calculation. The author also has carried out the requested calculation as it was the good chance to do the mutual comparison among various computation codes regarding electron transport calculation. The content that the WG requested to calculate was the absorbed dose at depth d mm when parallel electron beam enters at angle α into flat plate phantoms of PMMA, water and ICRU4-element tissue, which were placed in vacuum. The calculation was carried out by the versatile electron-photon shower computation Monte Carlo code, EGS4. As the results, depth dose curves and the dependence of absorbed dose on electron energy, incident angle and material are reported. The subjects to be investigated are pointed out. (K.I.)

  6. Dose reduction in evacuation proctography

    International Nuclear Information System (INIS)

    Hare, C.; Halligan, S.; Bartram, C.I.; Gupta, R.; Walker, A.E.; Renfrew, I.

    2001-01-01

    The goal of this study was to reduce the patient radiation dose from evacuation proctography. Ninety-eight consecutive adult patients referred for proctography to investigate difficult rectal evacuation were studied using a digital imaging system with either a standard digital program for barium examinations, a reduced dose digital program (both with and without additional copper filtration), or Video fluoroscopy. Dose-area products were recorded for each examination and the groups were compared. All four protocols produced technically acceptable examinations. The low-dose program with copper filtration (median dose 382 cGy cm 2 ) and Video fluoroscopy (median dose 705 cGy cm 2 ) were associated with significantly less dose than other groups (p < 0.0001). Patient dose during evacuation proctography can be reduced significantly without compromising the diagnostic quality of the examination. A digital program with added copper filtration conveyed the lowest dose. (orig.)

  7. Field investigation of surface-deposited radon progeny as a possible predictor of the airborne radon progeny dose rate.

    Science.gov (United States)

    Sun, Kainan; Steck, Daniel J; Field, R William

    2009-08-01

    The quantitative relationships between radon gas concentration, the surface-deposited activities of various radon progeny, the airborne radon progeny dose rate, and various residential environmental factors were investigated through actual field measurements in 38 selected Iowa houses occupied by either smokers or nonsmokers. Airborne dose rate was calculated from unattached and attached potential alpha energy concentrations (PAECs) using two dosimetric models with different activity-size weighting factors. These models are labeled Pdose and Jdose, respectively. Surface-deposited 218Po and 214Po were found significantly correlated to radon, unattached PAEC, and both airborne dose rates (p fireplace, or usage of a ceiling fan significantly, or marginally significantly, reduced the Pdose to 0.65 (90% CI 0.42-0.996), 0.54 (90% CI 0.28-1.02), and 0.66 (90% CI 0.45-0.96), respectively. For Jdose, only the usage of a ceiling fan significantly reduced the dose rate to 0.57 (90% CI 0.39-0.85). In smoking environments, deposited 218Po was a significant negative predictor for Pdose (RR 0.68, 90% CI 0.55-0.84) after adjusting for long-term 222Rn and environmental factors. A significant decrease of 0.72 (90% CI 0.64-0.83) in the mean Pdose was noted, after adjusting for the radon and radon progeny effects and other environmental factors, for every 10 additional cigarettes smoked in the room. A significant increase of 1.71 in the mean Pdose was found for large room size relative to small room size (90% CI 1.08-2.79) after adjusting for the radon and radon progeny effects as well as other environmental factors. Fireplace usage was found to significantly increase the mean Pdose to 1.71 (90% CI 1.20-2.45) after adjusting for other factors.

  8. Determination of organ doses and effective doses in radiooncology

    International Nuclear Information System (INIS)

    Roth, J.; Martinez, A.E.

    2007-01-01

    Background and Purpose: With an increasing chance of success in radiooncology, it is necessary to estimate the risk from radiation scatter to areas outside the target volume. The cancer risk from a radiation treatment can be estimated from the organ doses, allowing a somewhat limited effective dose to be estimated and compared. Material and Methods: The doses of the radiation-sensitive organs outside the target volume can be estimated with the aid of the PC program PERIDOSE developed by van der Giessen. The effective doses are determined according to the concept of ICRP, whereby the target volume and the associated organs related to it are not taken into consideration. Results: Organ doses outside the target volume are generally < 1% of the dose in the target volume. In some cases, however, they can be as high as 3%. The effective doses during radiotherapy are between 60 and 900 mSv, depending upon the specific target volume, the applied treatment technique, and the given dose in the ICRU point. Conclusion: For the estimation of the radiation risk, organ doses in radiooncology can be calculated with the aid of the PC program PERIDOSE. While evaluating the radiation risk after ICRP, for the calculation of the effective dose, the advanced age of many patients has to be considered to prevent that, e.g., the high gonad doses do not overestimate the effective dose. (orig.)

  9. Prediction of midline dose from entrance ad exit dose using OSLD measurements for total irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Heon; Park, Jong Min; Park, So Yeon; Chun, Min Soo; Han, Ji Hye; Cho, Jin Dong; Kim, Jung In [Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2017-06-15

    This study aims to predict the midline dose based on the entrance and exit doses from optically stimulated luminescence detector (OSLD) measurements for total body irradiation (TBI). For TBI treatment, beam data sets were measured for 6 MV and 15 MV beams. To evaluate the tissue lateral effect of various thicknesses, the midline dose and peak dose were measured using a solid water phantom (SWP) and ion chamber. The entrance and exit doses were measured using OSLDs. OSLDs were attached onto the central beam axis at the entrance and exit surfaces of the phantom. The predicted midline dose was evaluated as the sum of the entrance and exit doses by OSLD measurement. The ratio of the entrance dose to the exit dose was evaluated at various thicknesses. The ratio of the peak dose to the midline dose was 1.12 for a 30 cm thick SWP at both energies. When the patient thickness is greater than 30 cm, the 15 MV should be used to ensure dose homogeneity. The ratio of the entrance dose to the exit dose was less than 1.0 for thicknesses of less than 30 cm and 40 cm at 6 MV and 15 MV, respectively. Therefore, the predicted midline dose can be underestimated for thinner body. At 15 MV, the ratios were approximately 1.06 for a thickness of 50 cm. In cases where adult patients are treated with the 15 MV photon beam, it is possible for the predicted midline dose to be overestimated for parts of the body with a thickness of 50 cm or greater. The predicted midline dose and OSLD-measured midline dose depend on the phantom thickness. For in-vivo dosimetry of TBI, the measurement dose should be corrected in order to accurately predict the midline dose.

  10. Effects of surface relief on the high-dose sputtering of amorphous silicon and graphite by Ar ions

    International Nuclear Information System (INIS)

    Shulga, V.I.

    2014-01-01

    The effects of ion-induced surface relief on high-dose sputtering of amorphous silicon and graphite targets have been studied using binary-collision computer simulation. The relief was modeled as a wavelike surface along two mutually perpendicular surface axes (a 3D hillock-and-valley relief). Most simulations were carried out for normally-incident 30-keV Ar ions. It was shown that the surface relief can both increase and decrease the sputtering yield compared to that for a flat surface. The results of simulations suggest that stabilization of the surface relief is possible even in the absence of any smoothing processes such as surface diffusion of atoms. Effects of a surface relief on the experimentally measurable angular and energy distributions of sputtered atoms are also considered. The fitting parameters of these distributions are shown to be non-monotonic functions of the relief aspect ratio. The angular distribution of atoms sputtered from a relief surface is modulated to a great extent by the shape of the relief. For a rough surface, azimuthal isotropy of the angular distribution of sputtered atoms was found, but at high bombarding energies only

  11. Evaluation of entrance surface-skin doses in animals submitted on exams of abdomen in veterinary radiology using Tl dosimetry

    International Nuclear Information System (INIS)

    Veneziani, G. R.; Matsushima, L. C.; Campos, L. L.; Filho, A. M.

    2014-08-01

    The radiation protection has recently gained considerable attention in human medicine. In veterinary medicine has been some advances in radiodiagnostic and therapy for domestic animal like dogs and cats. It is notable the increase of the costs with domestic animals that are considered, by many people in the whole world, like members of family. However, an important parameter that must be taken into account is the increasing use of computed tomography and other equipment s that uses ionizing radiation, which may lead to comparatively high exposure of critical organs. The radiation dose is determined by the balance between therapeutic benefit and possible damage to surrounding normal tissues. This study aimed the evaluation of entrance surface-skin doses in dogs submitted to radiodiagnostic procedures of abdomen using the technique of thermoluminescent dosimetry (TLD). The radiation doses were measured using thermoluminescent dosimeters of LiF:Mg,Ti (TLD 100) and a dog phantom made with a plastic container, proportional to the dog size, fulfilled with water. (Author)

  12. Evaluation of entrance surface-skin doses in animals submitted on exams of abdomen in veterinary radiology using Tl dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Veneziani, G. R.; Matsushima, L. C.; Campos, L. L. [Instituto de Pesquisas Energeticas e Nucleares, Gerencia de Metrologia das Radiacoes / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil); Filho, A. M., E-mail: venezianigr@gmail.com [Centro Universitario de Rio Petro - UNIRP, Rodovia Br 153 (Transbrasiliana), Km. 69 Sao Jose do Rio Preto, Sao Paulo (Brazil)

    2014-08-15

    The radiation protection has recently gained considerable attention in human medicine. In veterinary medicine has been some advances in radiodiagnostic and therapy for domestic animal like dogs and cats. It is notable the increase of the costs with domestic animals that are considered, by many people in the whole world, like members of family. However, an important parameter that must be taken into account is the increasing use of computed tomography and other equipment s that uses ionizing radiation, which may lead to comparatively high exposure of critical organs. The radiation dose is determined by the balance between therapeutic benefit and possible damage to surrounding normal tissues. This study aimed the evaluation of entrance surface-skin doses in dogs submitted to radiodiagnostic procedures of abdomen using the technique of thermoluminescent dosimetry (TLD). The radiation doses were measured using thermoluminescent dosimeters of LiF:Mg,Ti (TLD 100) and a dog phantom made with a plastic container, proportional to the dog size, fulfilled with water. (Author)

  13. Use of three-dimensional lognormal dose-response surfaces in lifetime studies of radiation-induced cancer

    International Nuclear Information System (INIS)

    Raabe, O.G.

    1986-01-01

    The three-dimensional lognormal cumulative probability power function was used to provide a unifying dose-response description of the lifetime cancer risk for chronic exposure of experimental animals and people, for risk evaluation, and for scaling between species. Bone tumor fatilities, primarily from alpha irradiation of the skeleton in lifetime studies of beagles injected with 226 Ra, were shown to be well described by this function. This function described cancer risk in lifetime studies as a curved smooth surface depending on radiation exposure rate and elapsed time, such that the principal risk at low dose rates occurred near the end of the normal life span without significant life shortening. Essentially identical functions with the median value of the power function displaced with respect to appropriate RBE values were shown to describe bone-cancer induction primarily from alpha irradiation of the skeleton in lifetime beagle studies with injected 226 Ra, 228 Th, 239 Pu and 241 Am, and with inhaled 238 Pu. Application of this model to human exposures to 226 Ra yielded a response ratio of 3.6; that is, the time required for development of bone cancer in people was 3.6 times longer than for beagles at the same average skeletal dose rate. It was suggested that similar techniques were appropriate to other carcinogens and other critical organs. 20 refs., 8 figs., 3 tabs

  14. Intercomparison On Depth Dose Measurement

    International Nuclear Information System (INIS)

    Rohmah, N; Akhadi, M

    1996-01-01

    Intercomparation on personal dose evaluation system has been carried out between CSRSR-NAEA of Indonesia toward Standard Laboratory of JAERI (Japan) and ARL (Australia). The intercomparison was in 10 amm depth dose measurement , Hp (10), from the intercomparison result could be stated that personal depth dose measurement conducted by CSRSR was sufficiently good. Deviation of dose measurement result using personal dosemeter of TLD BG-1 type which were used by CSRSR in the intercomparison and routine photon personal dose monitoring was still in internationally agreed limit. Maximum deviation of reported doses by CSRSR compared to delivered doses for dosemeter irradiation by JAERI was -10.0 percent and by ARL was +29 percent. Maximum deviation permitted in personal dose monitoring is ± 50 percent

  15. Dose-to-man studies

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    Dose-to-Man Studies focused on developing computer data handling and computer modules which permit easy, rapid assessment of the dose to southeastern United States populations from routine or accidental releases of radionuclides to atmospheric and stream systems

  16. Dose monitoring in nuclear emergency

    International Nuclear Information System (INIS)

    Nan Hongjie; Yang Zhongping; Lei Xin

    2012-01-01

    In order to protect people from irradiation sickness and rebuild the radiation filed in nuclear emergency, personal and environmental dose need to be monitored. The application of TLD in dose monitoring is discussed in this paper. (authors)

  17. A review of radiology staff doses and dose monitoring requirements

    International Nuclear Information System (INIS)

    Martin, C. J.

    2009-01-01

    Studies of radiation doses received during X-ray procedures by radiology, cardiology and other clinical staff have been reviewed. Data for effective dose (E), and doses to the eyes, thyroid, hands and legs have been analysed. These data have been supplemented with local measurements to determine the most exposed part of the hand for monitoring purposes. There are ranges of 60-100 in doses to individual tissues reported in the literature for similar procedures at different centres. While ranges in the doses per unit dose-area product (DAP) are between 10 and 25, large variations in dose result from differences in the sensitivity of the X-ray equipment, the type of procedure and the operator technique, but protection factors are important in maintaining dose levels as low as possible. The influence of shielding devices is significant for determining the dose to the eyes and thyroid, and the position of the operator, which depends on the procedure, is the most significant factor determining doses to the hands. A second body dosemeter worn at the level of the collar is recommended for operators with high workloads for use in assessment of effective dose and the dose to the eye. It is proposed that the third quartile values from the distributions of dose per unit DAP identified in the review might be employed in predicting the orders of magnitude of doses to the eye, thyroid and hands, based on interventional operator workloads. Such dose estimates could be employed in risk assessments when reviewing protection and monitoring requirements. A dosemeter worn on the little finger of the hand nearest to the X-ray tube is recommended for monitoring the hand. (authors)

  18. Dose. Detriment. Limit assessment

    International Nuclear Information System (INIS)

    Breckow, J.

    2015-01-01

    One goal of radiation protection is the limitation of stochastic effects due to radiation exposure. The probability of occurrence of a radiation induced stochastic effect, however, is only one of several other parameters which determine the radiation detriment. Though the ICRP-concept of detriment is a quantitative definition, the kind of detriment weighting includes somewhat subjective elements. In this sense, the detriment-concept of ICRP represents already at the stage of effective dose a kind of assessment. Thus, by comparing radiation protection standards and concepts interconvertible or with those of environment or occupational protection one should be aware of the possibly different principles of detriment assessment.

  19. Radon dose and aerosols

    International Nuclear Information System (INIS)

    Planinic, J.; Radolic, V.; Faj, Z.; Vukovic, B.

    2000-01-01

    The equilibrium factor value (F) was measured in the NRPB radon chamber and the corresponding track density ratio (r = D/D 0 ) of bare (D) and diffusion (D 0 ) LR-115 nuclear track detectors was determined, as well as the regression equation F(r). Experiments with LR-115 nuclear track detectors and aerosol sources (burning candle and cigarette) were carried out in the Osijek University radon chamber and afterwards an empirical relationship between the equilibrium factor and aerosol concentration was derived. For the purpose of radon dose equivalent assessment, procedures for determining the unattached fraction of radon progeny were introduced using two nuclear track detectors. (author)

  20. High dose, heavy ion implantation into metals: the use of sacrificial surface layers to enhance retention

    International Nuclear Information System (INIS)

    Clapham, L.

    1994-01-01

    While of considerable interest for the production of metallic alloys, high dose, heavy ion implantation is highly problematical, since the process is limited by sputtering effects. Sputtering is less significant, however, for light target materials, such as C and Al. This paper summarizes studies involving the use of light materials (such as C and Al) which act as slowly sputtering ''sacrificial layers'' when deposited on metallic targets prior to heavy ion implantation. The use of C and Al sacrificial coatings has enabled implanted ion retentions of 100% to be obtained in a number of ion-metal target systems, where the retentions in uncoated samples were as low as 20%. Ion implantation invariably leads to mixing at the sacrificial layer-metal target interface. This mixing may be detrimental in certain systems, so it is useful to be able to minimize or remove this mixed region. To achieve this, a number of techniques have been investigated: (1) removal of the mixed region in the latter stages of the implant; (2) using a barrier layer or chemical effects to minimize mixing at the sacrificial layer-metal interface; (3) choosing a sacrificial layer material which forms a mixed region which has desirable properties. The results of these investigations, for a number of different ion-target systems, are outlined in this paper. (orig.)

  1. An evaluation of calculation parameters in the EGSnrc/BEAMnrc Monte Carlo codes and their effect on surface dose calculation

    International Nuclear Information System (INIS)

    Kim, Jung-Ha; Hill, Robin; Kuncic, Zdenka

    2012-01-01

    The Monte Carlo (MC) method has proven invaluable for radiation transport simulations to accurately determine radiation doses and is widely considered a reliable computational measure that can substitute a physical experiment where direct measurements are not possible or feasible. In the EGSnrc/BEAMnrc MC codes, there are several user-specified parameters and customized transport algorithms, which may affect the calculation results. In order to fully utilize the MC methods available in these codes, it is essential to understand all these options and to use them appropriately. In this study, the effects of the electron transport algorithms in EGSnrc/BEAMnrc, which are often a trade-off between calculation accuracy and efficiency, were investigated in the buildup region of a homogeneous water phantom and also in a heterogeneous phantom using the DOSRZnrc user code. The algorithms and parameters investigated include: boundary crossing algorithm (BCA), skin depth, electron step algorithm (ESA), global electron cutoff energy (ECUT) and electron production cutoff energy (AE). The variations in calculated buildup doses were found to be larger than 10% for different user-specified transport parameters. We found that using BCA = EXACT gave the best results in terms of accuracy and efficiency in calculating buildup doses using DOSRZnrc. In addition, using the ESA = PRESTA-I option was found to be the best way of reducing the total calculation time without losing accuracy in the results at high energies (few keV ∼ MeV). We also found that although choosing a higher ECUT/AE value in the beam modelling can dramatically improve computation efficiency, there is a significant trade-off in surface dose uncertainty. Our study demonstrates that a careful choice of user-specified transport parameters is required when conducting similar MC calculations. (note)

  2. Abdominal multi-detector row CT: Effectiveness of determining contrast medium dose on basis of body surface area

    International Nuclear Information System (INIS)

    Onishi, Hiromitsu; Murakami, Takamichi; Kim, Tonsok; Hori, Masatoshi; Osuga, Keigo; Tatsumi, Mitsuaki; Higashihara, Hiroki; Maeda, Noboru; Tsuboyama, Takahiro; Nakamoto, Atsushi; Tomoda, Kaname; Tomiyama, Noriyuki

    2011-01-01

    Purpose: To investigate the validity of determining the contrast medium dose based on body surface area (BSA) for the abdominal contrast-enhanced multi-detector row CT comparing with determining based on body weight (BW). Materials and methods: Institutional review committee approval was obtained. In this retrospective study, 191 patients those underwent abdominal contrast-enhanced multi-detector row CT were enrolled. All patients received 96 mL of 320 mg I/mL contrast medium at the rate of 3.2 mL. The iodine dose required to enhance 1 HU of the aorta at the arterial phase and that of liver parenchyma at portal venous phase per BSA were calculated (EU BSA ) and evaluated the relationship with BSA. Those per BW were also calculated (EU BW ) and evaluated. Estimated enhancement values (EEVs) of the aorta and liver parenchyma with two protocols for dose decision based on BSA and BW were calculated and patient-to-patient variability was compared between two protocols using the Levene test. Results: The mean of EU BSA and EU BW were 0.0621 g I/m 2 /HU and 0.00178 g I/kg/HU for the aorta, and 0.342 g I/m 2 /HU and 0.00978 g I/kg/HU for the liver parenchyma, respectively. In the aortic enhancement, EU BSA was almost constant regardless of BSA, and the mean absolute deviation of the EEV with the BSA protocol was significantly lower than that with the BW protocol (P < .001), although there was no significant difference between two protocols in the hepatic parenchymal enhancement (P = .92). Conclusion: For the aortic enhancement, determining the contrast medium dose based on BSA was considered to improve patient-to-patient enhancement variability.

  3. Hanford Environmental Dose Reconstruction Project

    International Nuclear Information System (INIS)

    Cannon, S.D.; Finch, S.M.

    1992-10-01

    The objective of the Hanford Environmental Dose Reconstruction (HEDR) Project is to estimate the radiation doses that individuals and populations could have received from nuclear operations at Hanford since 1944. The independent Technical Steering Panel (TSP) provides technical direction. The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed from release to impact on humans (dose estimates):Source Terms, Environmental Transport, Environmental Monitoring Data, Demography, Food Consumption, and Agriculture, and Environmental Pathways and Dose Estimates

  4. Effective dose and dose to crystalline lens during angiographic procedures

    International Nuclear Information System (INIS)

    Pages, J.

    1998-01-01

    The highest radiation doses levels received by radiologists are observed during interventional procedures. Doses to forehead and neck received by a radiologist executing angiographic examinations at the department of radiology at the academic hospital (AZ-VUB) have been measured for a group of 34 examinations. The doses to crystalline lens and the effective doses for a period of one year have been estimated. For the crystalline lens the maximum dose approaches the ICRP limit, that indicates the necessity for the radiologist to use leaded glasses. (N.C.)

  5. SU-E-T-244: Designing Low-Z Targets To Enhance Surface Dose: A Monte Carlo Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, R [Nova Scotia Cancer Centre, Halifax, NS (Canada); Robar, J [Capital District Health Authority, Halifax, NS (Canada); Parsons, D [Dalhousie University, Halifax, Nova Scotia (Canada)

    2015-06-15

    Purpose: Recent developments in The Varian Truebeam linac platform allows for the introduction of low-Z targets into the beam line for the imaging purposes. We have proposed using a low-Z target for radiation therapy purposes to enhance the surface dose during radiation treatment. The target arm of the Varian Truebeam accelerator consists of multiple targets with are linearly translated into the beam line. We have designed two Low-Z targets made of carbon: 1) a step target consisting of three steps of 15%, 30% and 60% CSDA range for 2.5 MeV electrons Figure 1a; 2) and a ramp target, an incline plane 2cm long with thicknesses ranging from 0% to 60% CSDA range, Figure 1b. The purpose of this work will determine the spectral characteristics of these target designs and determine if they have practical clinical applications for enhancing surface dose. Methods: To calculate the spectral characteristics of these targets, a standard Monte Carlo model of a Varian Clinac accelerator was used. Simulations were performed with a carbon step target, and a carbon ramp target, located at the same position as the electron foil in the rotating carousel. Simulations were carried out using a 2.5 MeV electron beam. Results: The step target design produced spectral characteristics which were similar to spectral model using a single disk target of the same thickness. The ramp target provides a means to have positional variation of the spectral components of the beam, however, the electron component as 60% CSDA us much broader than the step target. Conclusion: The carbon step-target provides a spectral distribution which is similar to a carbon disk of comparable thickness. The spectral distribution from the ramp-target can be modified as a function of position to provide a wide range of low energy electrons for surface dose enhancement.

  6. Dose of dialysis based on body surface area is markedly less in younger children than in older adolescents.

    Science.gov (United States)

    Daugirdas, John T; Hanna, Melisha G; Becker-Cohen, Rachel; Langman, Craig B

    2010-05-01

    BACKGROUND AND OBSERVATIONS: The current denominator for dosing dialysis is the urea distribution volume (V). Normalizing Kt/V to body surface area (S) has been proposed, but the implications of doing this in children have not been examined. Dialysis dose given to children and adolescents was calculated in terms of conventional V-based scaling and surface-area-normalized standard Kt/V (SAN-stdKt/V) calculated as stdKt/V x (Vant/S)/17.5, where Vant was an anthropometric estimate of V calculated using the Morgenstern equation. Formal 2-pool modeling was used to compute all dialysis adequacy outputs. In 34 children (11 girls, 23 boys) dialyzed 3 times a week, age range 1.4 to 18 years, the mean delivered equilibrated Kt/V (eKt/V) was 1.40, and the mean stdKt/V was 2.49, both of which tended to be higher in younger children. The ratio of Vant to S was 15.6 +/- 2.69 and was strongly associated with age between ages 2 and 16. SAN-stdKt/V averaged 2.21 and was strongly correlated with age between ages 2 and 16. If one considers a desired target for SAN-stdKt/V to be 2.45, all children less than 10 years of age were below target, despite having relatively high values of eKt/V and stdKt/V. If a surface-area-based denominator were to be adopted for dialysis dosing, most children under 10 years of age would receive markedly less dialysis than adolescent patients and would require 6- to 8-hour hemodialysis sessions or, for the youngest children, treatments given more frequently than 3 times/wk.

  7. Dose planning and dose delivery in radiation therapy

    International Nuclear Information System (INIS)

    Knoeoes, T.

    1991-01-01

    A method has been developed for calibration of CT-numbers to volumetric electron density distributions using tissue substitutes of known elemental composition and experimentally determined electron density. This information have been used in a dose calculation method based on photon and electron interaction processes. The method utilizes a convolution integral between the photon fluence matrix and dose distribution kernels. Inhomogeneous media are accounted for using the theorems of Fano and O'Connor for scaling dose distribution kernels in proportion to electron density. For clinical application of a calculated dose plan, a method for prediction of accelerator output have been developed. The methods gives the number of monitor units that has to be given to obtain a certain absorbed dose to a point inside an irregular, inhomogeneous object. The method for verification of dose distributions outlined in this study makes it possible to exclude the treatment related variance contributions, making an objective evaluation of dose calculations with experiments feasible. The methods for electron density determination, dose calculation and prediction of accelerator output discussed in this study will all contribute to an increased accuracy in the mean absorbed dose to the target volume. However, a substantial gain in the accuracy for the spatial absorbed dose distribution will also follow, especially using CT for mapping of electron density together with the dose calculation algorithm. (au)

  8. Normal tissue dose-effect models in biological dose optimisation

    International Nuclear Information System (INIS)

    Alber, M.

    2008-01-01

    Sophisticated radiotherapy techniques like intensity modulated radiotherapy with photons and protons rely on numerical dose optimisation. The evaluation of normal tissue dose distributions that deviate significantly from the common clinical routine and also the mathematical expression of desirable properties of a dose distribution is difficult. In essence, a dose evaluation model for normal tissues has to express the tissue specific volume effect. A formalism of local dose effect measures is presented, which can be applied to serial and parallel responding tissues as well as target volumes and physical dose penalties. These models allow a transparent description of the volume effect and an efficient control over the optimum dose distribution. They can be linked to normal tissue complication probability models and the equivalent uniform dose concept. In clinical applications, they provide a means to standardize normal tissue doses in the face of inevitable anatomical differences between patients and a vastly increased freedom to shape the dose, without being overly limiting like sets of dose-volume constraints. (orig.)

  9. Absorbed dose in CT. Comparison by CT dose index

    International Nuclear Information System (INIS)

    Yamamoto, Kenji; Akazawa, Hiroshi; Andou, Takashi

    2002-01-01

    Few reports have discussed the absorbed dose on CT units with increased scanning capacity even with the current widespread adoption of multi-slice CT units. To compare and investigate the dose indexes among CT units, we measured the absorbed dose on CT units operating in Nagano Prefecture Japan. The measurements showed proportionality between phantom absorbed dose and the exposured mAs values in conventional scanning operation. Further, the measurements showed that the absorbed dose in the center of the phantom differed by about 2.1-fold between the highest and lowest levels on individual CT units. Within a single company, multi-slice CT units of the same company gave absorbed doses of about 1.3 to 1.5 times those of conventional single-slice CT units under the same exposured conditions of conventional scanning. When the scanning pitch was reduced in helical scanning, the absorbed dose at the center of the phantom increased. (author)

  10. OMI/Aura Surface UVB Irradiance and Erythemal Dose Daily L2 Global 0.25 deg Lat/Lon Grid V003

    Data.gov (United States)

    National Aeronautics and Space Administration — The Version 003 of Aura-OMI Spectral Surface UVB Irradiance and Erythemal Dose Level-2G data product (Daily level-2 data binned into global 0.25 deg Lat/Lon grids)...

  11. New recommendations for dose equivalent

    International Nuclear Information System (INIS)

    Bengtsson, G.

    1985-01-01

    In its report 39, the International Commission on Radiation Units and Measurements (ICRU), has defined four new quantities for the determination of dose equivalents from external sources: the ambient dose equivalent, the directional dose equivalent, the individual dose equivalent, penetrating and the individual dose equivalent, superficial. The rationale behind these concepts and their practical application are discussed. Reference is made to numerical values of these quantities which will be the subject of a coming publication from the International Commission on Radiological Protection, ICRP. (Author)

  12. An investigation of entrance surface dose calculations for diagnostic radiology using Monte Carlo simulations and radiotherapy dosimetry formalisms

    International Nuclear Information System (INIS)

    Omrane, L Ben; Verhaegen, F; Chahed, N; Mtimet, S

    2003-01-01

    Our aim in this work was to investigate the methodology used in the determination of the entrance surface dose (ESD) in diagnostic radiology. In kV x-rays for low-energy photons (tube potential up to 160 kV, HVL: 1-8 mm Al), the ESD is based on the use of the ratio of mass-energy absorption coefficients and backscatter factors. A full simulation of the photon and electron transport in a kilovoltage x-ray unit, using the Monte Carlo code BEAM/EGS4, was performed to obtain an accurate beam phase space for use in dose calculation. The modelled phase space was experimentally validated for the beam qualities (measured HVL: 3.3 mm Al-2.2 mm Cu) and showed good agreement between calculated and measured HVLs, air kerma and relative dose distributions. We have computed the conversion factors from air kerma to water or soft tissue absorbed dose at the surface of a phantom for beam qualities (HVL: 3.3-8.35 mm Al). The same model was also used to calculate the ESD in water and in soft tissue for the low-energy photon range considered. The results show that the numerical differences between the air kerma and the water kerma based backscatter factors are insignificant. The same conclusion was reached for the (μ en /ρ) ratios, for soft tissue to air, evaluated using either the primary photon spectra or the spectra at the surface of a phantom. Furthermore, the good agreement obtained for the computation of the conversion factors with a full BEAM/EGS4 model confirms the previous studies which are based on different sources for the spectral distribution and different beam geometries (pencil beam or point source assumptions). On the other hand, the ESD in water or soft tissue is well described either with the B air or the B w formalism. Conversion factors from air kerma to ESD in these media are proposed in this work for several beam qualities in diagnostic radiology

  13. Sci-Thur PM – Brachytherapy 06: 3D Printed Surface Applicators for High Dose Rate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Clarke, Scott; Yewondwossen, Mammo; Robar, James [Dalhousie University, Nova Scotia Cancer Centre, Capital District Health Authority (Canada)

    2016-08-15

    Purpose: The purpose of this work is to develop a new applicator for administering high dose rate (HDR) brachytherapy using 3D printing technology. Primary advantages of using a 3D printed applicator will be to offer a more streamlined approach for therapists and patients while achieving better conformity, reproducibility, and patient specific applicators. Methods: A phantom study was conducted to measure the effectiveness of a 3D printed surface applicator by analyzing tumours on three locations of the body: the foot, nose, and scalp. The applicator was designed using Eclipse and further modified using Blender to create the catheter tunnels before being printed on a Lulzbot Taz 5 3D printer. A radiation plan was made using Oncentra Brachytherapy for a control treatment option using Freiburg Flaps and one with the novel method of a 3D printed applicator. A comparative analysis was made using D90, D100, V100, V150, and V200 Results: The 3D printed applicator showed comparable dose coverage with significant improvements on highly irregular surfaces when analyzed against a plan made using Freiburg Flaps. Although both plans exhibited complete tumour coverage, the 3D applicator showed improvements in D90 and V150 and the 3D applicator had a dose homogeneity index (DHI) of 0.99 compared to a DHI of 0.97 for the control. Therapist prep time also dropped significantly due to the lack of need for a thermoplastic mesh. Conclusions: 3D printed applicators for treatment of superficial sites proved to offer more patient convenience, less prep time, better conformity and tighter margins.

  14. Sci-Thur PM – Brachytherapy 06: 3D Printed Surface Applicators for High Dose Rate Brachytherapy

    International Nuclear Information System (INIS)

    Clarke, Scott; Yewondwossen, Mammo; Robar, James

    2016-01-01

    Purpose: The purpose of this work is to develop a new applicator for administering high dose rate (HDR) brachytherapy using 3D printing technology. Primary advantages of using a 3D printed applicator will be to offer a more streamlined approach for therapists and patients while achieving better conformity, reproducibility, and patient specific applicators. Methods: A phantom study was conducted to measure the effectiveness of a 3D printed surface applicator by analyzing tumours on three locations of the body: the foot, nose, and scalp. The applicator was designed using Eclipse and further modified using Blender to create the catheter tunnels before being printed on a Lulzbot Taz 5 3D printer. A radiation plan was made using Oncentra Brachytherapy for a control treatment option using Freiburg Flaps and one with the novel method of a 3D printed applicator. A comparative analysis was made using D90, D100, V100, V150, and V200 Results: The 3D printed applicator showed comparable dose coverage with significant improvements on highly irregular surfaces when analyzed against a plan made using Freiburg Flaps. Although both plans exhibited complete tumour coverage, the 3D applicator showed improvements in D90 and V150 and the 3D applicator had a dose homogeneity index (DHI) of 0.99 compared to a DHI of 0.97 for the control. Therapist prep time also dropped significantly due to the lack of need for a thermoplastic mesh. Conclusions: 3D printed applicators for treatment of superficial sites proved to offer more patient convenience, less prep time, better conformity and tighter margins.

  15. Variation of solubility, biokinetics and dose coefficient of industrial uranium oxides according to the specific surface area

    International Nuclear Information System (INIS)

    Chazel, V.; Houpert, P.; Ansorbolo, E.; Henge-Napoli, M.H.; Paquet, F.

    2000-01-01

    The in vitro solubility, absorption to blood, lung retention and dose coefficient of industrial UO 2 samples were studied as a function of the specific surface area (SSA) of the particles. An in vitro study has been carried out on two samples of industrial UO 4 to compare the results with those obtained with UO 2 . Ten UO 2 samples supplied by different fuel factories or research laboratories, presented specific surface areas from 1.00 to 4.45 m 2 .g -1 . The wide range of values of SSA was due to the different conditions of fabrication. Dissolution tests in cell culture medium made on these ten samples have shown that the solubility increased 2.5-fold when the SSA increased 1.7-fold. The same tendency has been found for UO 4 , a soluble compound, and for U 3 O 8 , a moderately soluble compound. Four in vivo experiments carried out on rats by intratracheal instillation of dust suspensions of UO 2 , have highlighted the decrease in lung retention and the increase of absorption to blood with the SSA. The experimental absorption parameters calculated from the in vivo data allowed specific dose coefficients to be obtained which decreased from 6.6 to 4.3 μSv.Bq -1 when the SSA increased from 1.60 to 3.08 m 2 .g -1 . Thus, the medical monitoring of workers at the workplace has to take into account any change in the fabrication process of the uranium compound which can affect the physiochemical properties and consequently the dose coefficient. (author)

  16. A Generalized Approach to Model the Spectra and Radiation Dose Rate of Solar Particle Events on the Surface of Mars

    Science.gov (United States)

    Guo, Jingnan; Zeitlin, Cary; Wimmer-Schweingruber, Robert F.; McDole, Thoren; Kühl, Patrick; Appel, Jan C.; Matthiä, Daniel; Krauss, Johannes; Köhler, Jan

    2018-01-01

    For future human missions to Mars, it is important to study the surface radiation environment during extreme and elevated conditions. In the long term, it is mainly galactic cosmic rays (GCRs) modulated by solar activity that contribute to the radiation on the surface of Mars, but intense solar energetic particle (SEP) events may induce acute health effects. Such events may enhance the radiation level significantly and should be detected as immediately as possible to prevent severe damage to humans and equipment. However, the energetic particle environment on the Martian surface is significantly different from that in deep space due to the influence of the Martian atmosphere. Depending on the intensity and shape of the original solar particle spectra, as well as particle types, the surface spectra may induce entirely different radiation effects. In order to give immediate and accurate alerts while avoiding unnecessary ones, it is important to model and well understand the atmospheric effect on the incoming SEPs, including both protons and helium ions. In this paper, we have developed a generalized approach to quickly model the surface response of any given incoming proton/helium ion spectra and have applied it to a set of historical large solar events, thus providing insights into the possible variety of surface radiation environments that may be induced during SEP events. Based on the statistical study of more than 30 significant solar events, we have obtained an empirical model for estimating the surface dose rate directly from the intensities of a power-law SEP spectra.

  17. Integral dose conservation in radiotherapy

    International Nuclear Information System (INIS)

    Reese, Adam S.; Das, Shiva K.; Curle, Charles; Marks, Lawrence B.

    2009-01-01

    Treatment planners frequently modify beam arrangements and use IMRT to improve target dose coverage while satisfying dose constraints on normal tissues. The authors herein analyze the limitations of these strategies and quantitatively assess the extent to which dose can be redistributed within the patient volume. Specifically, the authors hypothesize that (1) the normalized integral dose is constant across concentric shells of normal tissue surrounding the target (normalized to the average integral shell dose), (2) the normalized integral shell dose is constant across plans with different numbers and orientations of beams, and (3) the normalized integral shell dose is constant across plans when reducing the dose to a critical structure. Using the images of seven patients previously irradiated for cancer of brain or prostate cancer and one idealized scenario, competing three-dimensional conformal and IMRT plans were generated using different beam configurations. Within a given plan and for competing plans with a constant mean target dose, the normalized integral doses within concentric ''shells'' of surrounding normal tissue were quantitatively compared. Within each patient, the normalized integral dose to shells of normal tissue surrounding the target was relatively constant (1). Similarly, for each clinical scenario, the normalized integral dose for a given shell was also relatively constant regardless of the number and orientation of beams (2) or degree of sparing of a critical structure (3). 3D and IMRT planning tools can redistribute, rather than eliminate dose to the surrounding normal tissues (intuitively known by planners). More specifically, dose cannot be moved between shells surrounding the target but only within a shell. This implies that there are limitations in the extent to which a critical structure can be spared based on the location and geometry of the critical structure relative to the target.

  18. Statistical Review of surface dose in the period 1995-2010, measured by different types of TLD dosimeters

    International Nuclear Information System (INIS)

    Pastor Antolin, S.; Munoz Blasco, J.; Llansana Arnalot, J.; Gultresa Colomer, J.

    2011-01-01

    We analyzed the evolution of the number of special controls over the period 1985 to 2010 and the evolution of the doses in the period 1995 to 2010. Comparing the standard dose extremities respect to whole body in cases where users use both types of control in the same installation.

  19. Skin dose variation: influence of energy

    International Nuclear Information System (INIS)

    Cheung, T.; Yu, P.K.N.; Butson, M.J.; Cancer Services, Wollongong, NSW

    2004-01-01

    Full text: This research aimed to quantitatively evaluate the differences in percentage dose of maximum for 6MV and 18MV x-ray beams within the first lcm of interactions. Thus provide quantitative information regarding the basal, dermal and subcutaneous dose differences achievable with these two types of high-energy x-ray beams. Percentage dose of maximum build up curves are measured for most clinical field sizes using 6MV and 18MV x-ray beams. Calculations are performed to produce quantitative results highlighting the percentage dose of maximum differences delivered to various depths within the skin and subcutaneous tissue region by these two beams Results have shown that basal cell layer doses are not significantly different for 6MV and 18Mv x-ray beams At depths beyond the surface and basal cell layer there is a measurable and significant difference in delivered dose. This variation increases to 20% of maximum and 22% of maximum at Imm and 1cm depths respectively. The percentage variations are larger for smaller field sizes where the photon in phantom component of the delivered dose is the most significant contributor to dose By producing graphs or tables of % dose differences in the build up region we can provide quantitative information to the oncologist for consideration (if skin and subcutaneous tissue doses are of importance) during the beam energy selection process for treatment. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  20. Field Investigation of the Surface-deposited Radon Progeny as a Possible Predictor of the Airborne Radon Progeny Dose Rate

    Science.gov (United States)

    Sun, Kainan; Steck, Daniel J.; Field, R. William

    2009-01-01

    The quantitative relationships between radon gas concentration, the surface-deposited activities of various radon progeny, the airborne radon progeny dose rate, and various residential environmental factors were investigated through actual field measurements in 38 selected Iowa houses occupied by either smokers or nonsmokers. Airborne dose rate was calculated from unattached and attached potential alpha energy concentrations (PAECs) using two dosimetric models with different activity-size weighting factors. These models are labeled Pdose and Jdose, respectively. Surface-deposited 218Po and 214Po were found significantly correlated to radon, unattached PAEC, and both airborne dose rates (p fireplace, or usage of a ceiling fan significantly, or marginal significantly, reduced the Pdose to 0.65 (90% CI 0.42–0.996), 0.54 (90% CI 0.28–1.02) and 0.66 (90% CI 0.45–0.96), respectively. For Jdose, only the usage of a ceiling fan significantly reduced the dose rate to 0.57 (90% CI 0.39–0.85). In smoking environments, deposited 218Po was a significant negative predictor for Pdose (RR 0.68, 90% CI 0.55–0.84) after adjusting for long-term 222Rn and environmental factors. A significant decrease of 0.72 (90% CI 0.64–0.83) in the mean Pdose was noted, after adjusting for the radon and radon progeny effects and other environmental factors, for every 10 increasing cigarettes smoked in the room. A significant increase of 1.71 in the mean Pdose was found for large room size relative to small room size (90% CI 1.08–2.79) after adjusting for the radon and radon progeny effects as well as other environmental factors. Fireplace usage was found to significantly increase the mean Pdose to 1.71 (90% CI 1.20–2.45) after adjusting for other factors. PMID:19590273

  1. Patient and staff dose during hysterosalpinography

    International Nuclear Information System (INIS)

    Buls, N.; Osteaux, M.

    2001-01-01

    Hysterosalpingography (HSG) is a useful and widely employed technique which uses X-ray fluoroscopy to investigate the female genital tract. Fluoroscopy is assessed by a gynaecologist, a physician who is not always trained to work with ionising radiation. Dose-area product measurements in a group of 34 patients allowed an estimation of the median effective dose (0,83 mSv) and the median dose to the ovaries (1,63 mGy) of the patient per procedure. The dose to the staff was estimated using thermoluminescent dosimetry. The following median entrance surface doses were estimated per procedure: 0,22 mGy to the lens of the eye, 0,15 mGy to the neck at thyroid level and 0,19 mGy to the back of the hand. The annual eye dose limit could be exceeded if the gynaecologist is a member of the public. (author)

  2. SU-E-J-239: Influence of RF Coil Materials On Surface and Buildup Dose From a 6MV Photon Beam

    Energy Technology Data Exchange (ETDEWEB)

    Ghila, A; Fallone, B; Rathee, S [Cross Cancer Institute, Edmonton, AB (United Kingdom)

    2015-06-15

    Purpose: In order to perform real time tumour tracking using an integrated Linac-MR, images have to be acquired during irradiation. MRI uses RF coils in close proximity to the imaged volume. Given current RF coil designs this means that the high energy photons will be passing through the coil before reaching the patient. This study experimentally investigates the dose modifications that occur due to the presence of various RF coil materials in the treatment beam. Methods: Polycarbonate, copper or aluminum tape, and Teflon were used to emulate the base, conductor and cover respectively of a surface RF coil. These materials were placed at various distances from the surface of polystyrene or solid water phantoms which were irradiated in the presence of no magnetic field, a transverse 0.2T magnetic field, and a parallel 0.2T magnetic field. Percent depth doses were measured using ion chambers. Results: A significant increase in surface and buildup dose is observed. The surface dose is seen to decrease with an increasing separation between the emulated coil and the phantom surface, when no magnetic field is present. When a transverse magnetic field is applied the surface dose decreases faster with increasing separation, as some of the electrons created in the coil are curved away from the phantom’s surface. When a parallel field is present the surface dose stays approximately constant for small separations, only slightly decreasing for separations greater than 5cm, since the magnetic field focuses the electrons produced in the coil materials not allowing them to scatter. Conclusion: Irradiating a patient through an RF coil leads to an increase in the surface and buildup doses. Mitigating this increase is important for the successful clinical use of either a transverse or a parallel configuration Linac-MR unit. This project is partially supported by an operating grant from the Canadian Institute of Health Research (CIHR MOP 93752)

  3. Dose/dose-rate responses of shrimp larvae to UV-B radiation

    Energy Technology Data Exchange (ETDEWEB)

    Damkaer, D.M.; Dey, D.B.; Heron, G.A.

    1981-01-01

    Previous work indicated dose-rate thresholds in the effects of UV-B on the near-surface larvae of three shrimp species. Additional observations suggest that the total dose response varies with dose-rate. Below 0.002 Wm/sup -2/sub((DNA)) irradiance no significant effect is noted in activity, development, or survival. Beyond that dose-rate threshold, shrimp larvae are significantly affected if the total dose exceeds about 85 Jm/sup -2/sub((DNA)). Predictions cannot be made without both the dose-rate and the dose. These dose/dose-rate thresholds are compared to four-year mean dose/dose-rate solar UV-B irradiances at the experimental site, measured at the surface and calculated for 1 m depth. The probability that the shrimp larvae would receive lethal irradiance is low for the first half of the season of surface occurrence, even with a 44% increase in damaging UV radiation.

  4. Methods of bone marrow dose calculation

    International Nuclear Information System (INIS)

    Taboaco, R.C.

    1982-02-01

    Several methods of bone marrow dose calculation for photon irradiation were analised. After a critical analysis, the author proposes the adoption, by the Instituto de Radioprotecao e Dosimetria/CNEN, of Rosenstein's method for dose calculations in Radiodiagnostic examinations and Kramer's method in case of occupational irradiation. It was verified by Eckerman and Simpson that for monoenergetic gamma emitters uniformly distributed within the bone mineral of the skeleton the dose in the bone surface can be several times higher than dose in skeleton. In this way, is also proposed the Calculation of tissue-air ratios for bone surfaces in some irradiation geometries and photon energies to be included in the Rosenstein's method for organ dose calculation in Radiodiagnostic examinations. (Author) [pt

  5. Urban contamination and dose model

    International Nuclear Information System (INIS)

    Robertson, E.; Barry, P.J.

    1995-10-01

    Nuclear power reactors and other nuclear facilities are being built near or even within urban centres. Accidental releases of radionuclides to the atmosphere in built-up areas result in radiological exposure pathways that differ from those caused by releases in rural environments. Other than inhalation, exposure pathways involve external radiation from the plume while it passes and from radioactivity deposited onto the many and varied surfaces after it has passed. Radiation fields inside buildings are attenuated but many people are potentially exposed so while individual doses may be relatively low, population integrated doses may be high enough to cause concern. It is important, therefore, to assess the potential exposures and to estimate the cost-effectiveness of dose reduction measures in urban environments. This report describes a model developed to carry out such assessments. The model draws heavily on experience gained in European cities after their contamination fallout from the Chernobyl accident. Input is time integrated concentrations of specific radionuclides in urban air, obtained either by direct measurement or by prediction using an atmospheric dispersion model. The code includes default values for site specific variables and transfer parameters but the user is invited if desired to enter other values from the keyboard. Output is the time integrated dose rates for individuals selected because of the characteristic living, working and recreational habits. An accompanying manual documents the technical background on which the model is based and leads a first-time suer through various steps and operations encountered while the model is running. (author). 60 refs., 10 tabs., 1 fig

  6. In defence of collective dose

    International Nuclear Information System (INIS)

    Fairlie, I.; Sumner, D.

    2000-01-01

    Recent proposals for a new scheme of radiation protection leave little room for collective dose estimations. This article discusses the history and present use of collective doses for occupational, ALARA, EIS and other purposes with reference to practical industry papers and government reports. The linear no-threshold (LNT) hypothesis suggests that collective doses which consist of very small doses added together should be used. Moral and ethical questions are discussed, particularly the emphasis on individual doses to the exclusion of societal risks, uncertainty over effects into the distant future and hesitation over calculating collective detriments. It is concluded that for moral, practical and legal reasons, collective dose is a valid parameter which should continue to be used. (author)

  7. Evaluation of the enter surface dose, dose in organ and E effective dose, received by personnel and patients in studies of endoscopic retrograde cholangeopancreatography in the General Hospital of Mexico

    International Nuclear Information System (INIS)

    Reyes, S.; Gama T, G.; Beristain, M.; Espino, H.

    2006-01-01

    The ESD for patient and personal is measured: gastroenterologuist endoscopist G1, A1 Assistant and A2 instrumentist that carried out 22 independent therapeutic procedures of CPRE, in a fluoroscopy equipment Toshiba trademark with tube under the table, operated in automatic exposure mode, CAE to average tensions of 80 kVp. The measurement is carried out with film dosemeters of double emulsion Kodak Type 2 trademark, calibrated in terms of H * for the energy of the 137 Cs, first it is determined the films sensitivity like function of the optical density DO, and second the ESD for the effective energy of the radiation beam (50 keV), in three different points from the dosemeter (C, D and H). The films was placed for the personnel in: right hand, front (eye), thyroid and thorax (under D and out F of the lead apron); in the case of the patient three positions were used: thorax, hepatic region and pelvis. The mean values of the ESD and it standard deviation SD in mGy units are determined by: study, personnel, film position in doctor and patient, dosemeter measurement point. The calculated doses in organ are also determined for the patient in the thorax region, liverwort and pelvis its are agreement with the NRPB SR 262 report. Finally the H E and E for medical personnel and patients are estimated demonstrating that its are not exceeded the annual dose limits for the case of the OEP. In the case of the the OEP have for the D thorax an ESD max = 0.04 mGy that one corresponds an H E = 0.02 and E = 0.01 mSv. (Author)

  8. Monte Carlo based investigations of electron contamination from telecobalt unit head in build up region and its impact on surface dose.

    Science.gov (United States)

    Jagtap, A S; Palani Selvam, T; Patil, B J; Chavan, S T; Pethe, S N; Kulkarni, Gauri; Dahiwale, S S; Bhoraskar, V N; Dhole, S D

    2016-12-01

    A Telecobalt unit has wide range of applications in cancer treatments and is used widely in many countries all around the world. Estimation of surface dose in Cobalt-60 teletherapy machine becomes important since clinically useful photon beam consist of contaminated electrons during the patient treatment. EGSnrc along with the BEAMnrc user code was used to model the Theratron 780E telecobalt unit. Central axis depth dose profiles including surface doses have been estimated for the field sizes of 0×0, 6×6, 10×10, 15×15, 20×20, 25×25, 30×30cm 2 and at Source-to-surface distance (SSD) of 60 and 80cm. Surface dose was measured experimentally by the Gafchromic RTQA2 films and are in good agreement with the simulation results. The central axis depth dose data are compared with the data available from the British Journal of Radiology report no. 25. Contribution of contaminated electrons has also been calculated using Monte Carlo simulation by the different parts of the Cobalt-60 head for different field size and SSD's. Moreover, depth dose curve in zero area field size is calculated by extrapolation method and compared with the already published data. They are found in good agreement. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Experimental evaluation of neutron dose in radiotherapy patients: Which dose?

    Energy Technology Data Exchange (ETDEWEB)

    Romero-Expósito, M., E-mail: mariateresa.romero@uab.cat; Domingo, C.; Ortega-Gelabert, O.; Gallego, S. [Grup de Recerca en Radiacions Ionizants (GRRI), Departament de Física, Universitat Autònoma de Barcelona, Bellaterra 08193 (Spain); Sánchez-Doblado, F. [Departamento de Fisiología Médica y Biofísica, Universidad de Sevilla, Sevilla 41009 (Spain); Servicio de Radiofísica, Hospital Universitario Virgen Macarena, Sevilla 41009 (Spain)

    2016-01-15

    Purpose: The evaluation of peripheral dose has become a relevant issue recently, in particular, the contribution of secondary neutrons. However, after the revision of the Recommendations of the International Commission on Radiological Protection, there has been a lack of experimental procedure for its evaluation. Specifically, the problem comes from the replacement of organ dose equivalent by the organ-equivalent dose, being the latter “immeasurable” by definition. Therefore, dose equivalent has to be still used although it needs the calculation of the radiation quality factor Q, which depends on the unrestricted linear energy transfer, for the specific neutron irradiation conditions. On the other hand, equivalent dose is computed through the radiation weighting factor w{sub R}, which can be easily calculated using the continuous function provided by the recommendations. The aim of the paper is to compare the dose equivalent evaluated following the definition, that is, using Q, with the values obtained by replacing the quality factor with w{sub R}. Methods: Dose equivalents were estimated in selected points inside a phantom. Two types of medical environments were chosen for the irradiations: a photon- and a proton-therapy facility. For the estimation of dose equivalent, a poly-allyl-diglicol-carbonate-based neutron dosimeter was used for neutron fluence measurements and, additionally, Monte Carlo simulations were performed to obtain the energy spectrum of the fluence in each point. Results: The main contribution to dose equivalent comes from neutrons with energy higher than 0.1 MeV, even when they represent the smallest contribution in fluence. For this range of energy, the radiation quality factor and the radiation weighting factor are approximately equal. Then, dose equivalents evaluated using both factors are compatible, with differences below 12%. Conclusions: Quality factor can be replaced by the radiation weighting factor in the evaluation of dose

  10. Angular dependence of shallow dose

    International Nuclear Information System (INIS)

    Alvarez, J.L.

    1986-01-01

    The theoretical response of a detector is discussed and compared to measurements of shallow dose with tissue and phantom response detectors. A definite energy dependent angular response of dose and measurement was observed which could not be explained by simple trigonometric arguments. The response is back scatter dependent and must be considered in detector design and dose measurements. It is not possible for standard detectors to follow this response

  11. Full dose CHOP chemotherapy

    International Nuclear Information System (INIS)

    Tominaga, Shinichi; Kondo, Makoto; Ando, Yutaka; Yamashita, Shoji; Uematsu, Minoru; Shigematsu, Naoyuki; Nishiguchi, Iku; Hashimoto, Shozo

    1985-01-01

    Since 1982, we have performed 125 courses of CHOP chemotherapy for 27 patients of malignancy, adhering to the original regimen as strictly as possible. CHOP chemotherapy consisted of Cyclophosphamide 750 mg/m 2 , iv, on day 1; Adriamycin 50 mg/m 2 , iv, on day 1; Vincristine 1.4 mg/m 2 , iv, on day 1 (maximum single dose 2.0 mg) and Prednisolone 50 mg/m 2 , po, day 1 through 5. The cycle was repeated every 21 days. As side effects, myelosuppression, hair loss, fever, nausea, vomiting, liver dysfunction, stomatitis, neuropathy, herpes zoster, arrhythmia and hemorrhagic cystitis were seen. Due to myelosuppression, twenty patients experienced febrile episodes at each nadir of WBC counts on 40 courses. However, any febrile patient did not have life threatening infection. Other side effects were also reversible. The radiotherapy of most patients was carried out as initially scheduled, except for 3 patients in whom irradiation was interrupted due to severe stomatitis or herpes zoster. We consider that CHOP chemotherapy is excellent in feasibility even when combined with radiotherapy. (author)

  12. SU-E-T-09: A Clinical Implementation and Optimized Dosimetry Study of Freiberg Flap Skin Surface Treatment in High Dose Rate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Syh, J; Syh, J; Patel, B; Wu, H; Durci, M [Willis-Knighton Medical Center, Shreveport, LA (United States)

    2015-06-15

    Purpose: This case study was designated to confirm the optimized plan was used to treat skin surface of left leg in three stages. 1. To evaluate dose distribution and plan quality by alternating of the source loading catheters pattern in flexible Freiberg Flap skin surface (FFSS) applicator. 2. To investigate any impact on Dose Volume Histogram (DVH) of large superficial surface target volume coverage. 3. To compare the dose distribution if it was treated with electron beam. Methods: The Freiburg Flap is a flexible mesh style surface mold for skin radiation or intraoperative surface treatments. The Freiburg Flap consists of multiple spheres that are attached to each other, holding and guiding up to 18 treatment catheters. The Freiburg Flap also ensures a constant distance of 5mm from the treatment catheter to the surface. Three treatment trials with individual planning optimization were employed: 18 channels, 9 channels of FF and 6 MeV electron beam. The comparisons were highlighted in target coverage, dose conformity and dose sparing of surrounding tissues. Results: The first 18 channels brachytherapy plan was generated with 18 catheters inside the skin-wrapped up flap (Figure 1A). A second 9 catheters plan was generated associated with the same calculation points which were assigned to match prescription for target coverage as 18 catheters plan (Figure 1B). The optimized inverse plan was employed to reduce the dose to adjacent structures such as tibia or fibula. The comparison of DVH’s was depicted on Figure 2. External beam of electron RT plan was depicted in Figure 3. Overcall comparisons among these three were illustrated in Conclusion: The 9-channel Freiburg flap flexible skin applicator offers a reasonably acceptable plan without compromising the coverage. Electron beam was discouraged to use to treat curved skin surface because of low target coverage and high dose in adjacent tissues.

  13. Radiation dose in dental radiology

    International Nuclear Information System (INIS)

    Cohnen, M.; Kemper, J.; Moedder, U.; Moebes, O.; Pawelzik, J.

    2002-01-01

    The aim of this study was to compare radiation exposure in panoramic radiography (PR), dental CT, and digital volume tomography (DVT). An anthropomorphic Alderson-Rando phantom and two anatomical head phantoms with thermoluminescent dosimeters fixed at appropriate locations were exposed as in a dental examination. In PR and DVT, standard parameters were used while variables in CT included mA, pitch, and rotation time. Image noise was assessed in dental CT and DVT. Radiation doses to the skin and internal organs within the primary beam and resulting from scatter radiation were measured and expressed as maximum doses in mGy. For PR, DVT, and CT, these maximum doses were 0.65, 4.2, and 23 mGy. In dose-reduced CT protocols, radiation doses ranged from 10.9 to 6.1 mGy. Effective doses calculated on this basis showed values below 0.1 mSv for PR, DVT, and dose-reduced CT. Image noise was similar in DVT and low-dose CT. As radiation exposure and image noise of DVT is similar to low-dose CT, this imaging technique cannot be recommended as a general alternative to replace PR in dental radiology. (orig.)

  14. Hanford Environmental Dose Reconstruction Project

    International Nuclear Information System (INIS)

    Finch, S.M.; McMakin, A.H.

    1991-04-01

    The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation doses that populations could have received from nuclear operations at Hanford since 1944. The project is being managed and conducted by the Pacific Northwest Laboratory (PNL) under the direction of an independent Technical Steering Panel (TSP). The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed, from released to impact on humans (dose estimates): source terms; environmental transport; environmental monitoring data; demographics, agriculture, food habits; and, environmental pathways and dose estimates

  15. Occupational dose trends in Tanzania

    International Nuclear Information System (INIS)

    Muhogora, W.E.; Nyanda, A.M.; Ngaile, J.E.; Lema, U.S.

    1998-01-01

    This paper describes the present status of occupational radiation exposure of monitored workers in Tanzania from 1986 to 1997. The analysis of dose records observes over this period, a fluctuating trend both in the individual and collective doses. The trend is more related to the fluctuations of the number of radiation workers than to the possible radiation safety changes of the working conditions. It has been found that, the maximum annual dose for the worker in all work categories was about 18 mSv y -1 . This suggests that the occupational radiation exposure in all practices satisfies the current dose limitation system. The national exposure summary shows that, the highest collective dose of 12.8 man-Sv which is 90% of the total collective dose, was due to medical applications. The applications in industry and research had a contribution of nearly 0.8 and 0.7 man-Sv respectively. From the professional point of view, the medical diagnostic radiographers received the highest collective dose of 11.2 man-Sv. Although the medical physicists recorded the minimum collective dose of nearly 0.07 man-Sv, the data shows that this profession received the highest mean dose of about 33 mSv in 12 years. Some achievements of the personnel monitoring services and suggestions for future improvement are pointed out. (author)

  16. Prenatal radiation doses from radiopharmaceuticals

    International Nuclear Information System (INIS)

    Rojo, A.M.; Gomez Parada, I.M.; Di Trano, J.L.

    1998-01-01

    The radiopharmaceutical administration with diagnostic or therapeutic purpose during pregnancy implies a prenatal radiation dose. The dose assessment and the evaluation of the radiological risks become relevant due to the great radiosensitivity of the fetal tissues in development. This paper is a revision of the available data for estimating fetal doses in the cases of the more frequently used radiopharmaceuticals in nuclear medicine, taking into account recent investigation in placental crossover. The more frequent diagnostic and therapeutic procedures were analyzed according to the radiation doses implied. (author) [es

  17. Hanford Environmental Dose Reconstruction Project

    International Nuclear Information System (INIS)

    Finch, S.M.; McMakin, A.H.

    1992-06-01

    The objective of the Hanford Environmental Dose Reconstruction Project is to estimate the radiation doses that individuals and populations could have received from nuclear operations at Hanford since 1944. The project is being managed and conducted by the Battelle Pacific Northwest Laboratories under contract with the Centers for Disease Control. The independent Technical Steering Panel (TSP) provides technical direction. The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed, from release to impact on humans (dose estimates): source terms; environmental transport; environmental monitoring data; demography, food consumption, and agriculture; environmental pathways and dose estimates

  18. Radiation doses in interventional neuroradiology

    International Nuclear Information System (INIS)

    Theodorakou, C.; Butler, P.; Horrocks, J.A.

    2001-01-01

    Patient radiation doses during interventional radiology (IR) procedures may reach the thresholds for radiation-induced skin and eye lens injuries. This study investigates the radiation doses received by patients undergoing cerebral embolization. Measurements were conducted using thermoluminescent dosimeters. Radiotherapy verification films were used in order to visualise the radiation field. For each procedure the fluoroscopic and digital dose-area product, the fluoroscopic time, the total number of acquired images and entrance-skin dose calculated by the angiographic unit were recorded. In this paper, the skin, eye and thyroid glands doses on a sample of patients are presented. From a preliminary study of 13 patients having undergone cerebral embolization, it was deduced that six of them have received a dose above 1 Gy. Detailed dose data from patients undergoing IR procedures will be collected in the future with the aim of developing a model to allow estimation of the dose prior to the procedure as well as to look at techniques of dose reduction. (author)

  19. Gamma dosimetry of high doses

    International Nuclear Information System (INIS)

    Martinez C, T.; Galvan G, A.; Canizal, G.

    1991-01-01

    The gamma dosimetry of high doses is problematic in almost all the classic dosemeters either based on the thermoluminescence, electric, chemical properties, etc., because they are saturated to very high dose and they are no longer useful. This work carries out an investigation in the interval of high doses. The solid system of heptahydrate ferrous sulfate, can be used as solid dosemeter of routine for high doses of radiation. The proposed method is simple, cheap and it doesn't require sophisticated spectrophotometers or spectrometers but expensive and not common in some laboratories

  20. Spiral CT and radiation dose

    International Nuclear Information System (INIS)

    Imhof, H.; Schibany, N.; Ba-Ssalamah, A.; Czerny, C.; Hojreh, A.; Kainberger, F.; Krestan, C.; Kudler, H.; Noebauer, I.; Nowotny, R.

    2003-01-01

    Recent studies in the USA and Europe state that computed tomography (CT) scans compromise only 3-5% of all radiological exams, but they contribute 35-45% of total radiation dose to the patient population. These studies lead to concern by several public authorities. Basis of CT-dose measurements is the computed tomography dose index (CTDI), which was established 1981. Nowadays there are several modifications of the CTDI values, which may lead to confusion. It is suggested to use the standardized CTDI-100 w. value together with the dose length product in all CT-examinations. These values should be printed on all CT-images and allows an evaluation of the individualized patient dose. Nowadays, radiologist's aim must be to work at the lowest maximal diagnostic acceptable signal to noise ratio. To decrease radiation dose radiologist should use low kV and mA, but high pitches. Newly developed CT-dose-reduction soft-wares and filters should be installed in all CT-machines. We should critically compare the average dose used for a specific examination with the reference dose used in this country and/or Europe. Greater differences should caution the radiologist. Finally, we as radiologists must check very carefully all indications and recommend alternative imaging methods. But we have also to teach our customers--patients and medical doctors who are non-radiologists--that a 'good' image is not that which show all possible information, but that which visualize 'only' the diagnostic necessary information

  1. SU-F-T-621: Impact of Vacuum and Treatment Couch On Surface Dose in Stereotactic Body Radiation Therapy With and Without a Flattening Filter

    Energy Technology Data Exchange (ETDEWEB)

    Lan, HT; Lu, SH; Kuo, SH; Tsai, YC; Chen, LH; Wen, SY; Wang, CW [National Taiwan University Hospital, Taipei City, Taiwan (China)

    2016-06-15

    Purpose: When treating lung cancer patients with stereotactic body radiation therapy (SBRT), better immobilization is needed for accurate delivery of high-dose radiation. However, using a treatment couch (TrueBeamTM) and vacuum bag (BlueBAGTM) may increase the surface dose and skin toxicity. This study investigated the influence of couch and vacuum bag on the surface dose. Methods: The relative surface dose (D{sub 0}/DMAX) was measured in an ion-chamber (Markus-type PTW, 0.05cm{sup 3}) with a solid water phantom and SSD to 100 cm. A comprehensive comparison of different parameter settings, including the different energies (6MV-FFF, 10MV-FF, and 10MV-FFF), field sizes (3 X 3 cm{sup 2}, 5 × 5 cm{sup 2}, 8 × x cm{sup 2} , 10 × 10 cm{sup 2}, and 15 × 15 cm{sup 2}), thickness of the vacuum bag (5mm, 15mm, 30mm, 39mm and 55mm), and couch (with and without), was performed. Results: The FFF increases the surface dose as compared to FF mode. In a similar setting with field of 10 × 10 cm{sup 2}, FFF mode increases the surface dose from 26.0% to 32.8% for 6 MV, and 17.4% to 21.5% for 10 MV. When the beam passes through the couch, the surface dose increases to 3.6, 4.6, 2.9, and 3.7 times for 6 MV-FF, 10 MV-FF, 6 MV-FFF, and 10 MV-FFF, respectively. At the same energy, the surface dose increases to 3.93, 4.11, 4.23, 4.16 and 4.24 times at 5 mm, 15 mm, 30 mm, 39 mm and 55 mm thickness of the vacuum, respectively. Conclusion: Using a couch and vacuum significantly increases the surface dose. For SBRT with a superficial target close to the couch and immobilization vacuum, reduction of vacuum thickness and careful attention to skin dose in planning would be helpful in avoiding severe skin toxicity.

  2. Radiation dose rate measuring device

    International Nuclear Information System (INIS)

    Sorber, R.

    1987-01-01

    A portable device is described for in-field usage for measuring the dose rate of an ambient beta radiation field, comprising: a housing, substantially impervious to beta radiation, defining an ionization chamber and having an opening into the ionization chamber; beta radiation pervious electrically-conductive window means covering the opening and entrapping, within the ionization chamber, a quantity of gaseous molecules adapted to ionize upon impact with beta radiation particles; electrode means disposed within the ionization chamber and having a generally shallow concave surface terminating in a generally annular rim disposed at a substantially close spacing to the window means. It is configured to substantially conform to the window means to define a known beta radiation sensitive volume generally between the window means and the concave surface of the electrode means. The concave surface is effective to substantially fully expose the beta radiation sensitive volume to the radiation field over substantially the full ambient area faced by the window means

  3. Low doses effects and gamma radiations low dose rates

    International Nuclear Information System (INIS)

    Averbeck, D.

    1999-01-01

    This expose wishes for bringing some definitions and base facts relative to the problematics of low doses effects and low dose rates effects. It shows some already used methods and some actual experimental approaches by focusing on the effects of ionizing radiations with a low linear energy transfer. (N.C.)

  4. Do dose area product meter measurements reflect radiation doses ...

    African Journals Online (AJOL)

    Enrique

    SA JOURNAL OF RADIOLOGY • August 2004. Abstract. This study determined the correlation between radiation doses absorbed by health care workers and dose area product meter (DAP) measurements at Universitas Hospital, Bloemfontein. The DAP is an instrument which accurately measures the radiation emitted from ...

  5. Do dose area product meter measurements reflect radiation doses ...

    African Journals Online (AJOL)

    This study determined the correlation between radiation doses absorbed by health care workers and dose area product meter (DAP) measurements at Universitas Hospital, Bloemfontein. The DAP is an instrument which accurately measures the radiation emitted from the source. The study included the interventional ...

  6. Radioactivity concentrations and dose assessment in surface soil samples from east and south of Marmara region, Turkey.

    Science.gov (United States)

    Kiliç, Onder; Belivermis, Murat; Topçuoğlu, Sayhan; Cotuk, Yavuz; Coşkun, Mahmut; Cayir, Akin; Küçer, Rahmi

    2008-01-01

    The activity concentrations of 137Cs, 40K, 232Th, 238U and 226Ra were measured in surface soil samples from East and South of Marmara region, Turkey. The physico-chemical parameters (organic matter, CaCO3 contents and pH-value) of the soil samples were determined in the samples collected from 100 sampling stations. The average activity concentrations of 137Cs, 40K, 232Th, 238U and 226Ra were found to be 27.46+/-21.84, 442.51+/-189.85, 26.63+/-15.90, 21.77+/-12.08 and 22.45+/-13.31 Bq kg(-1), respectively. The mean value of total annual external gamma radiation dose equivalent for the natural radionuclides was calculated to be 54.86 microSv. The current data were compared with those found in the other locations of Turkey and different countries.

  7. A dose error evaluation study for 4D dose calculations

    Science.gov (United States)

    Milz, Stefan; Wilkens, Jan J.; Ullrich, Wolfgang

    2014-10-01

    Previous studies have shown that respiration induced motion is not negligible for Stereotactic Body Radiation Therapy. The intrafractional breathing induced motion influences the delivered dose distribution on the underlying patient geometry such as the lung or the abdomen. If a static geometry is used, a planning process for these indications does not represent the entire dynamic process. The quality of a full 4D dose calculation approach depends on the dose coordinate transformation process between deformable geometries. This article provides an evaluation study that introduces an advanced method to verify the quality of numerical dose transformation generated by four different algorithms. The used transformation metric value is based on the deviation of the dose mass histogram (DMH) and the mean dose throughout dose transformation. The study compares the results of four algorithms. In general, two elementary approaches are used: dose mapping and energy transformation. Dose interpolation (DIM) and an advanced concept, so called divergent dose mapping model (dDMM), are used for dose mapping. The algorithms are compared to the basic energy transformation model (bETM) and the energy mass congruent mapping (EMCM). For evaluation 900 small sample regions of interest (ROI) are generated inside an exemplary lung geometry (4DCT). A homogeneous fluence distribution is assumed for dose calculation inside the ROIs. The dose transformations are performed with the four different algorithms. The study investigates the DMH-metric and the mean dose metric for different scenarios (voxel sizes: 8 mm, 4 mm, 2 mm, 1 mm 9 different breathing phases). dDMM achieves the best transformation accuracy in all measured test cases with 3-5% lower errors than the other models. The results of dDMM are reasonable and most efficient in this study, although the model is simple and easy to implement. The EMCM model also achieved suitable results, but the approach requires a more complex

  8. SU-E-T-232: Custom High-Dose-Rate Brachytherapy Surface Mold Applicators: The Importance Source to Skin Distance

    International Nuclear Information System (INIS)

    Park, S; Demanes, J; Kamrava, M

    2015-01-01

    Purpose: Surface mold applicators can be customized to fit irregular skin surfaces that are difficult to treat with other radiation therapy techniques. Optimal design of customized HDR skin brachytherapy is not well-established. We evaluated the impact of applicator thickness (source to skin distance) on target dosimetry. Methods: 27 patients had 34 treated sites: scalp 4, face 13, extremity 13, and torso 4. Custom applicators were constructed from 5–15 mm thick thermoplastic bolus molded over the skin lesion. A planar array of plastic brachytherapy catheters spaced 5–10 mm apart was affixed to the bolus. CT simulation was used to contour the target volume and to determine the prescription depth. Inverse planning simulated annealing followed by graphical optimization was used to plan and deliver 40–56 Gy in 8–16 fractions. Target coverage parameters (D90, Dmean, and V100) and dose uniformity (V110–200, D0.1cc, D1cc, and D2cc) were studied according to target depth (<5mm vs. ≥5mm) and applicator thickness (5–10mm vs. ≥10mm). Results: The average prescription depth was 4.2±1.5mm. The average bolus thickness was 9.2±2.4mm. The median CTV volume was 10.0 cc (0.2–212.4 cc). Similar target coverage was achieved with prescription depths of <5mm and ≥5mm (Dmean = 113.8% vs. 112.4% and D90 = 100.2% vs. 98.3%). The <5mm prescription depth plans were more uniform (D0.1cc = 131.8% vs. 151.8%). Bolus thickness <10mm vs. ≥10mm plans also had similar target coverage (Dmean = 118.2% vs. 110.7% and D90 = 100.1% vs. 99.0%). Applicators ≥10mm thick, however, provide more uniform target dosimetry (D0.1cc = 146.9% vs. 139.5%). Conclusion: Prescription depth is based upon the thickness of the lesion and upon the clinical needs of the patient. Applicators ≥10mm thick provide more dose uniformity than 5–10mm thick applicators. Applicator thickness is an important variable that should be considered during treatment planning to achieve optimal dose uniformity

  9. Computer aided display of multiple soft tissue anatomical surfaces for simultaneous structural and area-dose appreciation in 3D-radiationtherapy planning. 115

    International Nuclear Information System (INIS)

    Moore, C.J.; Mott, D.J.; Wilkinson, J.M.

    1987-01-01

    For radiotherapy applications a 3D display that includes soft tissues is required but the presentation of all anatomical structures is often unnecessary and is potentially confusing. A tumour volume and a small number of critical organs, usually embedded within other soft tissue anatomy, are likely to be all that can be clearly displayed when presented in a 3D format. The inclusion of dose data (in the form of isodose lines or surfaces) adds to the complication of any 3D display. A solution to this problem is to incorporate the presentation of dose distribution into the technique used to provide the illusion of 3D. This illusion can be provided by either depth cueing or by the hypothetical illumination of spatially defined object surfaces. The dose distribution from irradiation fields or, in the case of brachytherapy from radioactive sources, can be regarded as a source of illumination for tumour and critical organs. The intensity of illumination at any point on a tissue surface represents the dose at that point. Such an approach also allows the variation of dose over a given surface (and by extension, over the corresponding volume) to be quantified using histogram techniques. This may be of value in analysing and comparing techniques in which vulnerable tissue surfaces are irradiated. The planning of intracavitary treatments for cervical cancer is one application which might benefit from the display approach described above. Here the variation of dose over the mucosal surfaces of the bladder and the rectum is of particular interest, since dose related morbidity has often been reported following these treatments. 7 refs.; 8 figs

  10. Analysis of surface contributions to external doses in a radioactively contaminated urban environment designed by the EMRAS-2 Urban Areas Working Group

    International Nuclear Information System (INIS)

    Hwang, Won Tae; Jeong, Hae Sun; Jeong, Hyo Joon; Kim, Eun Han; Han, Moon Hee; Kim, In Gyu

    2013-01-01

    Highlights: ► External dose and contribution from radio-activated surface were evaluated for EMRAS-2 Urban Areas Working Group scenarios. ► The external doses showed a distinctive difference with the locations and precipitation. ► The contribution of contaminated surfaces for external dose depends on locations and precipitation. ► These results provide the essential information for decision-making support of countermeasures. - Abstract: The EMRAS-2 Urban Areas Working Group, which is supported by the IAEA, has designed a variety of accidental scenarios to test and improve the capabilities of the models used for an evaluation of radioactive contamination in an urban environment. A variety of models including a Korean model, METRO-K, are used for predictive results on the hypothetical scenarios. This paper describes the predictive results of METRO-K for the hypothetical scenarios designed in the Working Group. The external dose resulting from the air contamination of Co-60 was evaluated, and its contribution was analyzed with time as a function of the location of a receptor and precipitation conditions at the time of the contamination event. As a result, the external doses showed a distinctive difference with the locations to be evaluated and the precipitation conditions. Moreover, the contribution of contaminated surfaces for external doses was strongly dependent on the locations to be evaluated and the precipitation conditions. These results will provide essential information to assist the decision-making of appropriate countermeasures in an emergency situation of a radioactively contaminated urban environment

  11. Maximization of DRAM yield by control of surface charge and particle addition during high dose implantation

    Science.gov (United States)

    Horvath, J.; Moffatt, S.

    1991-04-01

    Ion implantation processing exposes semiconductor devices to an energetic ion beam in order to deposit dopant ions in shallow layers. In addition to this primary process, foreign materials are deposited as particles and surface films. The deposition of particles is a major cause of IC yield loss and becomes even more significant as device dimensions are decreased. Control of particle addition in a high-volume production environment requires procedures to limit beamline and endstation sources, control of particle transport, cleaning procedures and a well grounded preventative maintenance philosophy. Control of surface charge by optimization of the ion beam and electron shower conditions and measurement with a real-time charge sensor has been effective in improving the yield of NMOS and CMOS DRAMs. Control of surface voltages to a range between 0 and -20 V was correlated with good implant yield with PI9200 implanters for p + and n + source-drain implants.

  12. Dose optimization of intra-operative high dose rate interstitial brachytherapy implants for soft tissue sarcoma

    Directory of Open Access Journals (Sweden)

    Jamema Swamidas

    2009-01-01

    Full Text Available Objective : A three dimensional (3D image-based dosimetric study to quantitatively compare geometric vs. dose-point optimization in combination with graphical optimization for interstitial brachytherapy of soft tissue sarcoma (STS. Materials and Methods : Fifteen consecutive STS patients, treated with intra-operative, interstitial Brachytherapy, were enrolled in this dosimetric study. Treatment plans were generated using dose points situated at the "central plane between the catheters", "between the catheters throughout the implanted volume", at "distances perpendicular to the implant axis" and "on the surface of the target volume" Geometrically optimized plans had dose points defined between the catheters, while dose-point optimized plans had dose points defined at a plane perpendicular to the implant axis and on the target surface. Each plan was graphically optimized and compared using dose volume indices. Results : Target coverage was suboptimal with coverage index (CI = 0.67 when dose points were defined at the central plane while it was superior when the dose points were defined at the target surface (CI=0.93. The coverage of graphically optimized plans (GrO was similar to non-GrO with dose points defined on surface or perpendicular to the implant axis. A similar pattern was noticed with conformity index (0.61 vs. 0.82. GrO were more conformal and less homogeneous compared to non-GrO. Sum index was superior for dose points defined on the surface of the target and relatively inferior for plans with dose points at other locations (1.35 vs. 1.27. Conclusions : Optimization with dose points defined away from the implant plane and on target results in superior target coverage with optimal values of other indices. GrO offer better target coverage for implants with non-uniform geometry and target volume.

  13. Time and dose in carcinogenesis

    International Nuclear Information System (INIS)

    Mayneord, W.V.; Clarke, R.H.

    1978-05-01

    Previous work on the implications of different forms of dose response relationships is extended to include time as a variable, not only in time of irradiation but also in the time of appearance of effects following irradiation. The forms of relationships for time distribution of tumours revealed experimentally for both radiation and chemical carcinogens are first considered. It appears that much data may be correlated in terms of a log-normal distribution of tumour yield following the insult. Further, it is noted, that there is evidence that the median time of tumour appearance may be a function of total dose received or even of dose rate for protracted exposure. Using numerical values of these parameters derived from the biological literature speculative studies have been made of the effects on dose response relationships of using a time distribution of tumour yield, considering both uniform irradiation and point sources. In addition the effects of using dose rate rather than dose to define the log-normal distribution to tumour appearance have been investigated. It is assumed that biological response is directly proportional to dose but that effect is distributed in time. From this linear assumption the appearance of non-linear dose response relationships and apparent thresholds are continually seen. Finally, both the importance of attempting analyses of biological data in terms of stochastic concepts and the need for biological data to test our hypotheses is emphasised. (author)

  14. EPA's Benchmark Dose Modeling Software

    Science.gov (United States)

    The EPA developed the Benchmark Dose Software (BMDS) as a tool to help Agency risk assessors facilitate applying benchmark dose (BMD) method’s to EPA’s human health risk assessment (HHRA) documents. The application of BMD methods overcomes many well know limitations ...

  15. Microbeams, microdosimetry and specific dose

    International Nuclear Information System (INIS)

    Randers-Pehrson, H.

    2002-01-01

    Dose and its usefulness as a single parameter to describe the amount of radiation absorbed are well established for most situations. The conditions where the concept of dose starts to break down are well known, mostly from the study of microdosimetry. For low doses of high LET radiation it is noted that the process of taking the limiting value of the energy absorbed within a test volume divided by the mass within that volume yields either zero or a relatively large value. The problem is further exacerbated with microbeam irradiations where the uniformity of the energy deposition is experimentally manipulated on the spatial scale of cells being irradiated. Booz introduced a quantity to deal with these problems: the unfortunately named 'mean specific energy in affected volumes'. This quantity multiplied by the probability that a test volume has received an energy deposit is equal to dose (in situations where dose can be defined). I propose that Booz's quantity be renamed 'specific dose', that is the mean energy deposited divided by the mass within a specified volume. If we believe for instance that the nucleus of a cell is the critical volume for biological effects, we can refer to the nuclear specific dose. A microbeam experiment wherein 10 per cent of the cell nuclei were targeted with 10 alpha particles would be described as delivering a nuclear specific dose of 1.6 Gy to 10 per cent of the population. (author)

  16. Radiation absorbed doses in cephalography

    International Nuclear Information System (INIS)

    Eliasson, S.; Julin, P.; Richter, S.; Stenstroem, B.

    1984-01-01

    Radiation absorbed doses to different organs in the head and neck region in lateral (LAT) and postero-anterior (PA) cephalography were investigated. The doses were measured by thermoluminescence dosimeters (TLD) on a tissue equivalent phantom head. Lanthanide screens in speed group 4 were used at 90 and 85 k Vp. A near-focus aluminium dodger was used and the radiation beam was collimated strictly to the face. The maximum entrance dose from LAT was 0.25 mGy and 0.42 mGy from a PA exposure. The doses to the salivary glands ranged between 0.2 and 0.02 mGy at LAT and between 0.15 and 0.04 mGy at PA exposures. The average thyroid gland dose without any shielding was 0.11 mGy (LAT) and 0.06 mGy (PA). When a dodger was used the dose was reduced to 0.07 mGy (LAT). If the thyroid gland was sheilded off, the dose was further reduced to 0.01 mGy and if the thyroid region was collimated out of the primary radiation field the dose was reduced to only 0.005 mGy. (authors)

  17. Central index of dose information

    International Nuclear Information System (INIS)

    1991-01-01

    The Central Index of Dose Information (CIDI) is a national database of occupational exposure to radiation operated by the NRPB as agent for the Health and Safety Executive. It receives summarised information on the radiation doses to classified persons in Great Britain annually from Approved Dosimetry Services. This document is the first annual CIDI summary of the data, giving statistics for 1986. (UK)

  18. Device for determining the gross weight, dose rate, surface contamination and/or nuclide inventory

    International Nuclear Information System (INIS)

    1987-01-01

    Barrels with low nuclide inventories (about 1E6 Bq) and with high inventories (1E13 Bq) are inspected with the barrel inspection system. The system provides a rotating plate, which is part of some scales and a measuring sensor arrangement for this purpose. The surface contamination and nuclide inventories of the 200 litre barrels can be calculated from the weight and radiation detector values. (DG) [de

  19. Manual of dose evaluation from atmospheric releases

    Energy Technology Data Exchange (ETDEWEB)

    Shirvaikar, V V; Abrol, V [Health Physics Division, Bhabha Atomic Research Centre, Bombay (India)

    1978-07-01

    The problem of dose evaluation from atmospheric releases is reduced to simple arithmetic by giving tables of concentrations and time integrated concentrations for instantaneous plumes and long time (1 year), sector averaged plumes for distances upto 10 km, effective release heights of upto 200 m and the six Pasquill stability classes. Correction factors for decay, depletion due to deposition and rainout are also given. Inhalation doses, immersion doses and contamination levels can be obtained from these by using multiplicative factors tabulated for various isotopes of significance. Tables of external gamma doses from plume are given separately for various gamma energies. Tables are also given to evaluate external beta and gamma dose rates from contaminated surfaces. The manual also discusses the basic diffusion model relevant to the problem. (author)

  20. Dose optimisation in computed radiography

    International Nuclear Information System (INIS)

    Schreiner-Karoussou, A.

    2005-01-01

    After the installation of computed radiography (CR) systems in three hospitals in Luxembourg a patient dose survey was carried out for three radiographic examinations, thorax, pelvis and lumbar spine. It was found that the patient doses had changed in comparison with the patient doses measured for conventional radiography in the same three hospitals. A close collaboration between the manufacturers of the X-ray installations, the CR imaging systems and the medical physicists led to the discovery that the speed class with which each radiographic examination was to be performed, had been ignored, during installation of the digital imaging systems. A number of procedures were carried out in order to calibrate and program the X-ray installations in conjunction with the CR systems. Following this optimisation procedure, a new patient dose survey was carried out for the three radiographic examinations. It was found that patient doses for the three hospitals were reduced. (authors)

  1. Evolution of radon dose evaluation

    Directory of Open Access Journals (Sweden)

    Fujimoto Kenzo

    2004-01-01

    Full Text Available The historical change of radon dose evaluation is reviewed based on the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR reports. Since 1955, radon has been recognized as one of the important sources of exposure of the general public. However, it was not really understood that radon is the largest dose contributor until 1977 when a new concept of effective dose equivalent was introduced by International Commission on Radiological Protection. In 1982, the dose concept was also adapted by UNSCEAR and evaluated per caput dose from natural radiation. Many researches have been carried out since then. However, lots of questions have remained open in radon problems, such as the radiation weighting factor of 20 for alpha rays and the large discrepancy of risk estimation among dosimetric and epidemiological approaches.

  2. Bone and marrow dose modeling

    International Nuclear Information System (INIS)

    Stabin, Michael G.

    2004-01-01

    Nuclear medicine therapy is being used increasingly in the treatment of cancer (thyroid, leukemia/lymphoma with RIT, primary and secondary bone malignancies, and neuroblastomas). In all cases it is marrow toxicity that limits the amount of treatment that can be administered safely. Marrow dose calculations are more difficult than for many major organs because of the intricate association of bone and soft tissue elements. In RIT, there appears to be no consensus on how to calculate that dose accurately, or of individual patients ability to tolerate planned therapy. Available dose models are designed after an idealized average, healthy individual. Patient-specific methods are applied in evaluation of biokinetic data, and need to be developed for treatment of the physical data (dose conversion factors) as well: age, prior patient therapy, disease status. Contributors to marrow dose: electrons and photons

  3. Radiation dose during angiographic procedures

    International Nuclear Information System (INIS)

    Lavoie, Ch.; Rasuli, P.

    2001-01-01

    The use of angiographic procedures is becoming more prevalent as new techniques and equipment are developed. There have been concerns in the scientific community about the level of radiation doses received by patients, and indirectly by staff, during some of these radiological procedures. The purpose of this study was to assess the level of radiation dose from angiographic procedures to patient at the Ottawa Hospital, General Campus. Radiation dose measurements, using Thermo-Luminescent Dosimeters (TLDs), were performed on more than 100 patients on various procedures. The results show that while the patient dose from the great majority of angiographic procedures is less than 2 Gy, a significant number of procedures, especially interventional procedures may have doses greater than 2 Gy and may lead to deterministic effects. (author)

  4. Labour cost of radiation dose

    International Nuclear Information System (INIS)

    Cook, A.; Lockett, L.E.

    1978-01-01

    In order to optimise capital expenditure on measures to protect workers against radiation it would be useful to have a means to measure radiation dose in money terms. Because labour has to be employed to perform radiation work there must be some relationship between the wages paid and the doses received. Where the next increment of radiation dose requires additional labour to be recruited the cost will at least equal the cost of the extra labour employed. This paper examines some of the factors which affect the variability of the labour cost of radiation dose and notes that for 'in-plant' exposures the current cost per rem appears to be significantly higher than values quoted in ICRP Publication 22. An example is given showing how this concept may be used to determine the capital it is worth spending on installed plant to prevent regular increments of radiation dose to workers. (author)

  5. Establishment Of Dose Correlation During Dose Mapping On Medical Devices

    International Nuclear Information System (INIS)

    Ruzalina Baharin; Hasan Sham; Ahsanulkhaliqin Abdul Wahab

    2014-01-01

    This paper explains the work done during product dose mapping in order to get the correlation between doses at MINTec-Sinagama plant. Product used was medical devices in aluminium tubes packaged in cardboard kegs packaging with average weight of 12 kg per carton. 12 cartons were loaded in every one tote to give 0.2 g/ cm 3 of density. Ceric cerous dosimeters were placed at specific locations as indicated in SP14: Product Dose Mapping, QMS of MINTec-Sinagama around three planes. Three processes were made at different days as a three replicates to show the reproducibility of measurements. (author)

  6. Dosimetric systems of high dose, dose rate and dose uniformity in food and medical products

    International Nuclear Information System (INIS)

    Vargas, J.; Vivanco, M.; Castro, E.

    2014-08-01

    In the Instituto Peruano de Energia Nuclear (IPEN) we use the chemical dosimetry Astm-E-1026 Fricke as a standard dosimetric system of reference and different routine dosimetric systems of high doses, according to the applied doses to obtain the desired effects in the treated products and the doses range determined for each type of dosimeter. Fricke dosimetry is a chemical dosimeter in aqueous solution indicating the absorbed dose by means an increase in absorbance at a specific wavelength. A calibrated spectrophotometer with controlled temperature is used to measure absorbance. The adsorbed dose range should cover from 20 to 400 Gy, the Fricke solution is extremely sensitive to organic impurities, to traces of metal ions, in preparing chemical products of reactive grade must be used and the water purity is very important. Using the referential standard dosimetric system Fricke, was determined to March 5, 2013, using the referential standard dosimetric system Astm-1026 Fricke, were irradiated in triplicate Fricke dosimeters, to 5 irradiation times (20; 30; 40; 50 and 60 seconds) and by linear regression, the dose rate of 5.400648 kGy /h was determined in the central point of the irradiation chamber (irradiator Gamma cell 220 Excel), applying the decay formula, was compared with the obtained results by manufacturers by means the same dosimetric system in the year of its manufacture, being this to the date 5.44691 kGy /h, with an error rate of 0.85. After considering that the dosimetric solution responds to the results, we proceeded to the irradiation of a sample of 200 g of cereal instant food, 2 dosimeters were placed at the lateral ends of the central position to maximum dose and 2 dosimeters in upper and lower ends as minimum dose, they were applied same irradiation times; for statistical analysis, the maximum dose rate was 6.1006 kGy /h and the minimum dose rate of 5.2185 kGy /h; with a dose uniformity of 1.16. In medical material of micro pulverized bone for

  7. Estimates of surface deposition of radioactivity and radiation doses resulting from proposed NNTRP activities

    International Nuclear Information System (INIS)

    Gudiksen, P.H.; Peterson, K.R.

    1975-04-01

    The National Nuclear Test Readiness Program (NNTRP) has been developed by the AEC (now ERDA) and DOD to maintain a state of readiness for the prompt resumption of atmospheric nuclear testing if circumstances warrant such resumption. Such proposed tests would be conducted at the Pacific Test Site. The environmental consequences of the program were assessed. Estimations were made of the magnitude and distribution of radioactive debris deposited on the surface waters of the Pacific Ocean as a result of the test and of the total person-rem to the Continental U.S. and Hawaiian Islands populations. Since the proposed test series consists of a wide range of weapon yields to be detonated at various altitudes and the specific number and types of tests change with time according to national defense needs, a set of seven representative tests were selected for performing a parametric yield analysis at various burst locations and heights. The yields were selected to cover the low intermediate, intermediate, and low megaton ranges. The respective yields, detonation heights, and ground zero locations of the seven bursts were considered. The atmospheric transport and diffusion models that were used are described and the meteorological and radiological input data used, and the results of the calculations are included. (U.S.)

  8. Standardization of high-dose measurement of electron and gamma ray absorbed doses and dose rates

    International Nuclear Information System (INIS)

    McLaughlin, W.L.

    1985-01-01

    Intense electron beams and gamma radiation fields are used for sterilizing medical devices, treating municipal wastes, processing industrial goods, controlling parasites and pathogens, and extending the shelf-life of foods. Quality control of such radiation processes depends largely on maintaining measurement quality assurance through sound dosimetry procedures in the research leading to each process, in the commissioning of that process, and in the routine dose monitoring practices. This affords documentation as to whether satisfactory dose uniformity is maintained throughout the product and throughout the process. Therefore, dosimetry at high doses and dose rates must in many radiation processes be standardized carefully, so that 'dosimetry release' of a product is verified. This standardization is initiated through preliminary dosimetry intercomparison studies such as those sponsored recently by the IAEA. This is followed by establishing periodic exercises in traceability to national or international standards of absorbed dose and dose rate. Traceability is achieved by careful selection of dosimetry methods and proven reference dosimeters capable of giving sufficiently accurate and precise 'transfer' dose assessments: (1) they must be calibrated or have well-established radiation-yield indices; (2) their radiation response characteristics must be reproducible and cover the dose range of interest; (3) they must withstand the rigours of back-and-forth mailing between a central standardizing laboratory and radiation processing facilities, without excessive errors arising due to instabilities, dosimeter batch non-uniformities, and environmental and handling stresses. (author)

  9. Radiation dose estimates for radiopharmaceuticals

    International Nuclear Information System (INIS)

    Stabin, M.G.; Stubbs, J.B.; Toohey, R.E.

    1996-04-01

    Tables of radiation dose estimates based on the Cristy-Eckerman adult male phantom are provided for a number of radiopharmaceuticals commonly used in nuclear medicine. Radiation dose estimates are listed for all major source organs, and several other organs of interest. The dose estimates were calculated using the MIRD Technique as implemented in the MIRDOSE3 computer code, developed by the Oak Ridge Institute for Science and Education, Radiation Internal Dose Information Center. In this code, residence times for source organs are used with decay data from the MIRD Radionuclide Data and Decay Schemes to produce estimates of radiation dose to organs of standardized phantoms representing individuals of different ages. The adult male phantom of the Cristy-Eckerman phantom series is different from the MIRD 5, or Reference Man phantom in several aspects, the most important of which is the difference in the masses and absorbed fractions for the active (red) marrow. The absorbed fractions for flow energy photons striking the marrow are also different. Other minor differences exist, but are not likely to significantly affect dose estimates calculated with the two phantoms. Assumptions which support each of the dose estimates appears at the bottom of the table of estimates for a given radiopharmaceutical. In most cases, the model kinetics or organ residence times are explicitly given. The results presented here can easily be extended to include other radiopharmaceuticals or phantoms

  10. Effects of small radiation doses

    International Nuclear Information System (INIS)

    Fuchs, G.

    1986-01-01

    The term 'small radiation dosis' means doses of about (1 rem), fractions of one rem as well as doses of a few rem. Doses like these are encountered in various practical fields, e.g. in X-ray diagnosis, in the environment and in radiation protection rules. The knowledge about small doses is derived from the same two forces, on which the radiobiology of human beings nearly is based: interpretation of the Hiroshima and Nagasaki data, as well as the experience from radiotherapy. Careful interpretation of Hiroshima dates do not provide any evidence that small doses can induce cancer, fetal malformations or genetic damage. Yet in radiotherapy of various diseases, e.g. inflammations, doses of about 1 Gy (100 rad) do no harm to the patients. According to a widespread hypothesis even very small doses may induce some types of radiation damage ('no threshold'). Nevertheless an alternative view is justified. At present no decision can be made between these two alternatives, but the usefullness of radiology is definitely better established than any damage calculated by theories or extrapolations. Based on experience any exaggerated fear of radiations can be met. (author)

  11. Patient dose in neonatal units

    International Nuclear Information System (INIS)

    Smans, K.; Struelens, L.; Smet, M.; Bosmans, H.; Vanhavere, F.

    2008-01-01

    Lung disease represents one of the most life-threatening conditions in prematurely born children. In the evaluation of the neonatal chest, the primary and most important diagnostic study is therefore the chest radiograph. Since prematurely born children are very sensitive to radiation, those radiographs may lead to a significant radiation detriment. Hence, knowledge of the patient dose is necessary to justify the exposures. A study to assess the patient doses was started at the neonatal intensive care unit (NICU) of the Univ. Hospital in Leuven. Between September 2004 and September 2005, prematurely born babies underwent on average 10 X-ray examinations in the NICU. In this sample, the maximum was 78 X-ray examinations. For chest radiographs, the median entrance skin dose was 34 μGy and the median dose area product was 7.1 mGy.cm 2 . By means of conversion coefficients, the measured values were converted to organ doses. Organ doses were calculated for three different weight classes: extremely low birth weight infants ( 2500 g). The doses to the lungs for a single chest radiograph for infants with extremely low birth weights, low birth weights and normal birth weights were 24, 25 and 32 μGy, respectively. (authors)

  12. CT dose reduction in children

    International Nuclear Information System (INIS)

    Vock, Peter

    2005-01-01

    World wide, the number of CT studies in children and the radiation exposure by CT increases. The same energy dose has a greater biological impact in children than in adults, and scan parameters have to be adapted to the smaller diameter of the juvenile body. Based on seven rules, a practical approach to paediatric CT is shown: Justification and patient preparation are important steps before scanning, and they differ from the preparation of adult patients. The subsequent choice of scan parameters aims at obtaining the minimal signal-to-noise ratio and volume coverage needed in a specific medical situation; exposure can be divided in two aspects: the CT dose index determining energy deposition per rotation and the dose-length product (DLP) determining the volume dose. DLP closely parallels the effective dose, the best parameter of the biological impact. Modern scanners offer dose modulation to locally minimise exposure while maintaining image quality. Beyond the selection of the physical parameters, the dose can be kept low by scanning the minimal length of the body and by avoiding any non-qualified repeated scanning of parts of the body. Following these rules, paediatric CT examinations of good quality can be obtained at a reasonable cost of radiation exposure. (orig.)

  13. Plutonium dose-effect relationship

    International Nuclear Information System (INIS)

    Matsuoka, Osamu

    1976-01-01

    Dose in internal exposure to Pu was investigated, and dose-effect relationship was discussed. Dose-effect relationship in internal exposure was investigated by means of two methods, which were relationship between dose and its effect (relationship between μ Ci/Kg and its effect), and exposure dose and its effects (rad-effect), and merits and demerits of two methods were mentioned. Problems in a indication method such as mean dose were discussed with respect to the dose in skeleton, the liver and the lung. Pu-induced osteosarcoma in mice rats, and beagles was described, and differences in its induction between animals were discussed. Pulmonary neoplasma induced by 239 PuO 2 inhalation in beagles was reported, and description was made as to differences in induction of lung cancer between animals when Pu was inhaled and was taken into the lung. A theoretical and experimental study of a extrapolation of the results of the animal experiment using Pu to human cases is necessary. (Serizawa, K.)

  14. Concrete spent fuel storage casks dose rates

    International Nuclear Information System (INIS)

    Bace, M.; Jecmenica, R.; Trontl, K.

    1998-01-01

    Our intention was to model a series of concrete storage casks based on TranStor system storage cask VSC-24, and calculate the dose rates at the surface of the casks as a function of extended burnup and a prolonged cooling time. All of the modeled casks have been filled with the original multi-assembly sealed basket. The thickness of the concrete shield has been varied. A series of dose rate calculations for different burnup and cooling time values have been performed. The results of the calculations show rather conservative original design of the VSC-24 system, considering only the dose rate values, and appropriate design considering heat rejection.(author)

  15. Dose concentration and dose verification for radiotherapy of cancer

    International Nuclear Information System (INIS)

    Maruyama, Koichi

    2005-01-01

    The number of cancer treatments using radiation therapy is increasing. The background of this increase is the accumulated fact that the number of successful cases is comparative to or even better than surgery for some types of cancer due to the improvement in irradiation technology and radiation planning technology. This review describes the principles and technology of radiation therapy, its characteristics, particle therapy that improves the dose concentration, its historical background, the importance of dose concentration, present situation and future possibilities. There are serious problems that hinder the superior dose concentration of particle therapy. Recent programs and our efforts to solve these problems are described. A new concept is required to satisfy the notion of evidence based medicine, i.e., one has to develop a method of dose verification, which is not yet available. This review is for researchers, medical doctors and radiation technologists who are developing this field. (author)

  16. Pharmacokinetically guided dosing of (high-dose) chemotherapeutic agents

    NARCIS (Netherlands)

    Attema-de Jonge, M.E. (Milly Ellen)

    2004-01-01

    Due to variation in drug distribution, metabolism and elimination processes between patients, systemic exposure to chemotherapeutic agents may be highly variable from patient to patient after administration of similar doses. This pharmacokinetic variability may explain in part the large variability

  17. Doses in mammography. Preliminary study

    International Nuclear Information System (INIS)

    Marquez P, F.; Acosta R, N.; Universidad Nacional Mayor de San Marcos, Lima; Benavente, T.; Universidad Nacional Mayor de San Marcos, Lima; Poma, M.

    2002-01-01

    Mammography is the most important method to detect lesions in the breast with this technique one can detect small tumours before clear clinical symptoms appear. Mammographic image of require high quality standards due that the extremely low contrast between the normal and pathological areas in the breast, eg.g., they have similar attenuation and absorption coefficient. The x-ray mammographic systems, used in this study are Senographe 500t and Senographe DMR, a detector with a RadCal ionization chambers calibrated to the qualities of mammographic x-ray beams, and a breast simulator that is a phantoms of polymethylmethacrylate (PMMA) of several thicknesses with the equivalence of 50% of the glandular tissue. The results obtained indicate that the values of doses at the entrance surface of a breast (DES) are greater the reference value 20 mGy to 5,0 cm of PMMA and the values of the mean glandular dose (MGD) exceed the reference value of 2,1 mGy for 5,1 cm of compressed thick breast. We consider that the values high of the EDS and MGD are due that the x-ray systems no meeting in good condition or for used of x-ray spectra no suitable, so is recommendable be carried out test of quality control to the x-ray systems and also realize studies, or characterize the of x-ray mammographic spectra

  18. Effective doses in paediatric radiology

    International Nuclear Information System (INIS)

    Iacob, Olga; Diaconescu, Cornelia; Roca, Antoaneta

    2001-01-01

    Because of their longer life expectancy, the risk of late manifestations of detrimental radiation effects is greater in children than in adults and, consequently, paediatric radiology gives ground for more concern regarding radiation protection than radiology of adults. The purpose of our study is to assess in terms of effective doses the magnitude of paediatric patient exposure during conventional X-ray examinations, selected for their high frequency or their relatively high doses to the patient. Effective doses have been derived from measurements of dose-area product (DAP) carried out on over 900 patients undergoing X-ray examinations, in five paediatric units. The conversion coefficients for estimating effective doses are those calculated by the NRPB using Monte-Carlo technique on a series of 5 mathematical phantoms representing 0, 1, 5, 10 and 15 year old children. The annual frequency of X-ray examinations necessary for collective dose calculation are those reported in our last national study on medical exposure, conducted in 1995. The annual effective doses from all medical examinations for the average paediatric patient are as follows: 1.05 mSv for 0 year old, 0.98 mSv for 1 year old, 0.53 mSv for 5 year old, 0.65 mSv for 10 year old and 0.70 mSv for 15 year old. The resulting annual collective effective dose was evaluated at 625 man Sv with the largest contribution of pelvis and hip examinations (34%). The annual collective effective associated with paediatric radiology in Romania represent 5% of the annual value resulting from all diagnostic radiology. Examination of the chest is by far the most frequent procedure for children, accounting for about 60 per cent of all annually performed X-ray conventional examinations. Knowledge of real level of patient dose is an essential component of quality assurance programs in paediatric radiology. (authors)

  19. Late effects of low doses and dose rates

    International Nuclear Information System (INIS)

    Paretzke, H.G.

    1980-01-01

    This paper outlines the spectrum of problems and approaches used in work on the derivation of quantitative prognoses of late effects in man of low doses and dose rates. The origins of principal problems encountered in radiation risks assessments, definitions and explanations of useful quantities, methods of deriving risk factors from biological and epidemiological data, and concepts of risk evaluation and problems of acceptance are individually discussed

  20. Effects of low doses; Effet des faibles doses

    Energy Technology Data Exchange (ETDEWEB)

    Le Guen, B. [Electricite de France (EDF-LAM-SCAST), 93 - Saint-Denis (France)

    2001-07-01

    Actually, even though it is comfortable for the risk management, the hypothesis of the dose-effect relationship linearity is not confirmed for any model. In particular, in the area of low dose rate delivered by low let emitters. this hypothesis is debated at the light of recent observations, notably these ones relative to the mechanisms leading to genetic instability and induction eventuality of DNA repair. The problem of strong let emitters is still to solve. (N.C.)

  1. Savannah River Site dose control

    International Nuclear Information System (INIS)

    Smith, L.S.

    1992-01-01

    Health physicists from the Brookhaven National Laboratory (BNL) visited the Savannah River Site (SRS) as one of 12 facilities operated by the Department of Energy (DOE) contractors with annual collective dose equivalents greater than 100 person-rem (100 person-cSv). Their charter was to review, evaluate and summarize as low as reasonably achievable (ALARA) techniques, methods and practices as implemented. This presentation gives an overview of the two selected ALARA practices implemented at the SRS: Administrative Exposure Limits and Goal Setting. These dose control methods are used to assure that individual and collective occupational doses are ALARA and within regulatory limits

  2. Are low radiation doses Dangerous?

    International Nuclear Information System (INIS)

    Garcia Lima, O.; Cornejo, N.

    1996-01-01

    In the last few years the answers to this questions has been affirmative as well as negative from a radiation protection point of view low doses of ionizing radiation potentially constitute an agent causing stochasting effects. A lineal relation without threshold is assumed between dose and probability of occurrence of these effects . Arguments against the danger of probability of occurrence of these effects. Arguments again the danger of low dose radiation are reflected in concepts such as Hormesis and adaptive response, which are phenomena that being studied at present

  3. What is correct: equivalent dose or dose equivalent

    International Nuclear Information System (INIS)

    Franic, Z.

    1994-01-01

    In Croatian language some physical quantities in radiation protection dosimetry have not precise names. Consequently, in practice either terms in English or mathematical formulas are used. The situation is even worse since the Croatian language only a limited number of textbooks, reference books and other papers are available. This paper compares the concept of ''dose equivalent'' as outlined in International Commission on Radiological Protection (ICRP) recommendations No. 26 and newest, conceptually different concept of ''equivalent dose'' which is introduced in ICRP 60. It was found out that Croatian terminology is both not uniform and unprecise. For the term ''dose equivalent'' was, under influence of Russian and Serbian languages, often used as term ''equivalent dose'' even from the point of view of ICRP 26 recommendations, which was not justified. Unfortunately, even now, in Croatia the legal unit still ''dose equivalent'' defined as in ICRP 26, but the term used for it is ''equivalent dose''. Therefore, in Croatian legislation a modified set of quantities introduced in ICRP 60, should be incorporated as soon as possible

  4. Analysis of operators' surface doses in the common endovascular and on-vascular interventional diagnosis and treatment

    International Nuclear Information System (INIS)

    Zhang Lin; Zhu Jianguo; Min Nan; Lu Feng

    2011-01-01

    Objective: To contrast the level of radiation doses of Lead protective clothing both inside and outside in different parts of the body of the first and second operators and touring nurse in common endovascular and non-vascular interventional diagnosis and treatment. Methods: We choose the common endovascular interventional diagnosis and treatment in the head, thorax, abdomen, such as Cerebral angiography, Coronary angiography, Transcatheter arterial chemoembolization and non-vascular interventional diagnosis and treatment such as Endoscopic Retrograde Cholangio-Pancreatography and Percutaneous transhepatic cholangial drainage as experiment objects. Put the thermoluminescence dosimeter on the different spots of Lead protective clothing of subjects (Inside and outside the lead cap and the lead collar, inside and outside of the lead protective clothing in chest and abdomen, left upper arm outside of lead protective clothing, back of the left hand) and X-ray machine outgoing port when the operation was going on. After that, measure the thermoluminescence dosimeter, calculate and analyze exposure doses inside and outside of the lead protective clothing. Results: The skin doses of operators in different types of interventional diagnosis and treatment are listed in Table 1to Table 4; exposure doses of touring nurses are very low; the doses of X-ray machine outgoing port are mostly over the measuring range. Conclusion: The protection of Lead clothes plays a significant role in these two types of interventional diagnosis and treatment based on the conclusion that the dose of inside of Lead clothes is less than that of outside. We should enhance the operators' protection and administration in the process of intervention and arise the conscious of self-protection, to avoid the unnecessary radiation exposure. (authors)

  5. Method to stimulate dose gradient in liquid media

    International Nuclear Information System (INIS)

    Scarlat, F.

    1993-01-01

    The depth absorbed dose from electrons with energy higher than 10 MeV shows a distribution with a big-percentage absorbed dose at the entrance surface and a small dose gradient. This is due to the big distance between the virtual focus and irradiated liquid medium. In order to stimulate dose gradient and decrease the surface dose, this paper presents a method for obtaining the second focus by means of a magnetostatic planar wiggler. Preliminary calculations indicated that the absorbed dose rate increases two-three times at the reference plane in the irradiated liquid medium. (Author)

  6. Health effect of low dose/low dose rate radiation

    International Nuclear Information System (INIS)

    Kodama, Seiji

    2012-01-01

    The clarified and non-clarified scientific knowledge is discussed to consider the cause of confusion of explanation of the title subject. The low dose is defined roughly lower than 200 mGy and low dose rate, 0.05 mGy/min. The health effect is evaluated from 2 aspects of clinical symptom/radiation hazard protection. In the clinical aspect, the effect is classified in physical (early and late) and genetic ones, and is classified in stochastic (no threshold value, TV) and deterministic (with TV) ones from the radioprotection aspect. Although the absence of TV in the carcinogenic and genetic effects has not been proved, ICRP employs the stochastic standpoint from the safety aspect for radioprotection. The lowest human TV known now is 100 mGy, meaning that human deterministic effect would not be generated below this dose. Genetic deterministic effect can be observable only in animal experiments. These facts suggest that the practical risk of exposure to <100 mGy in human is the carcinogenesis. The relationship between carcinogenic risk in A-bomb survivors and their exposed dose are found fitted to the linear no TV model, but the epidemiologic data, because of restriction of subject number analyzed, do not always mean that the model is applicable even below the dose <100 mGy. This would be one of confusing causes in explanation: no carcinogenic risk at <100 mGy or risk linear to dose even at <100 mGy, neither of which is scientifically conclusive at present. Also mentioned is the scarce risk of cancer in residents living in the high background radiation regions in the world in comparison with that in the A-bomb survivors exposed to the chronic or acute low dose/dose rate. Molecular events are explained for the low-dose radiation-induced DNA damage and its repair, gene mutation and chromosome aberration, hypothesis of carcinogenesis by mutation, and non-targeting effect of radiation (bystander effect and gene instability). Further researches to elucidate the low dose

  7. Dose determination in computed tomography

    International Nuclear Information System (INIS)

    Descamps, C.; Garrigo, E.; Venencia, D.; Gonzalez, M.; Germanier, A.

    2011-10-01

    In the last years the methodologies to determine the dose in computed tomography have been revised. In this work was realized a dosimetric study about the exploration protocols used for simulation of radiotherapy treatments. The methodology described in the Report No. 111 of the American Association of Medical Physiques on a computed tomograph of two cuts was applied. A cylindrical phantom of water was used with dimensions: 30 cm of diameter and 50 cm of longitude that simulates the absorption and dispersion conditions of a mature body of size average. The doses were determined with ionization chamber and thermoluminescent dosimetry. The results indicate that the dose information that provides the tomograph underestimates the dose between 32 and 35%.

  8. Dose from drinking water Finland

    International Nuclear Information System (INIS)

    Maekelaeinen, Ilona; Salonen, Laina; Huikuri, Pia; Arvela, Hannu

    1999-01-01

    The dose from drinking water originates almost totally from naturally occurring radionuclides in the uranium-238 series, the most important nuclide being radon-222. Second comes lead-210, and third polonium-210. The mean age-group-weighted dose received by ingestion of drinking water is 0.14 mSv per year. More than half of the total cumulative dose of 750 manSv is received by the users of private wells, forming 13% of the population. The most exposed group comprises the users of wells drilled in bedrock, who receive 320 manSv while comprising only 4% of the population. The calculated number of annual cancer incidences due to drinking water is very sensitive to the dose-conversion factors of ingested radon used, as well as to the estimated lung cancer incidences caused by radon released from water into indoor air. (au)

  9. Doses from Medical Radiation Sources

    Science.gov (United States)

    ... Medical Radiation Sources Michael G. Stabin, PhD, CHP Introduction Radiation exposures from diagnostic medical examinations are generally ... of exposure annually to natural background radiation. Plain Film X Rays Single Radiographs Effective Dose, mSv Skull ( ...

  10. Gamma Radiation Doses In Sweden

    International Nuclear Information System (INIS)

    Almgren, Sara; Isaksson, Mats; Barregaard, Lars

    2008-01-01

    Gamma dose rate measurements were performed in one urban and one rural area using thermoluminescence dosimeters (TLD) worn by 46 participants and placed in their dwellings. The personal effective dose rates were 0.096±0.019(1 SD) and 0.092±0.016(1 SD)μSv/h in the urban and rural area, respectively. The corresponding dose rates in the dwellings were 0.11±0.042(1 SD) and 0.091±0.026(1 SD)μSv/h. However, the differences between the areas were not significant. The values were higher in buildings made of concrete than of wood and higher in apartments than in detached houses. Also, 222 Rn measurements were performed in each dwelling, which showed no correlation with the gamma dose rates in the dwellings

  11. Extremity doses to interventional radiologists

    International Nuclear Information System (INIS)

    Wihtby, M.; Martin, C. J.

    2002-01-01

    Radiologists performing interventional procedures are often required to stand close to the patient's side when carrying out manipulations under fluoroscopic control. This can result in their extremities receiving a high radiation dose, due to scattered radiation. These doses are sometimes high enough to warrant that the radiologist in question be designated a classified radiation worker. Classification in the UK is a result of any worker receiving or likely to receive in the course of their duties in excess of 3/10ths of any annual dose limit (500mSv to extremities, skin). The doses to the legs of radiologists have received less attention than those to the hands, however the doses may be high, due to the proximity of the legs and feet to scattered radiation. The legs can be exposed to a relatively high level of scattered radiation as the radiation in produced from scatter of the un attenuated beam from the bottom of the patient couch. The routine monitoring of extremity doses in interventional radiology is difficult due to several factors. Firstly a wide range of interventional procedures in undertaken in every radiology department, and these procedures require many different techniques, equipment and skills. This means that the position the radiologist adopts in relation to scattering medium and therefore their exposure, depends heavily on the type of procedure. As the hands which manipulate the catheters within the patient are often located close to the patients side and to the area under irradiation, the distribution of dose across the hands can be variable, with very high localised doses, making routine monitoring difficult. The purpose of this study was to determine the magnitude and distribution of dose to the hands and legs of interventional radiologists carrying out a wide range of both diagnostic and therapeutic interventional procedures. To ascertain the most effective method of monitoring the highest dose in accordance with the Basic safety standards

  12. Calculating radiation exposure and dose

    International Nuclear Information System (INIS)

    Hondros, J.

    1987-01-01

    This paper discusses the methods and procedures used to calculate the radiation exposures and radiation doses to designated employees of the Olympic Dam Project. Each of the three major exposure pathways are examined. These are: gamma irradiation, radon daughter inhalation and radioactive dust inhalation. A further section presents ICRP methodology for combining individual pathway exposures to give a total dose figure. Computer programs used for calculations and data storage are also presented briefly

  13. Dose assessment at Bikini Atoll

    International Nuclear Information System (INIS)

    Robison, W.L.; Phillips, W.A.; Colsher, C.S.

    1977-01-01

    Bikini Atoll is one of two sites in the northern Marshall Islands that was used by the United States as testing grounds for the nuclear weapons program from 1946 to 1958. In 1969 a general cleanup began at Bikini Atoll. Subsistence crops, coconut and Pandanus fruit, were planted on Bikini and Eneu Islands, and housing was constructed on Bikini Island. A second phase of housing was planned for the interior of Bikini Island. Preliminary data indicated that external gamma doses in the interior of the island might be higher than in other parts of the island. Therefore, to select a second site for housing on the island with minimum external exposure, a survey of Bikini Atoll was conducted in June 1975. External gamma measurements were made on Bikini and Eneu Islands, and soil and vegetations samples collected to evaluate the potential doses via terrestrial food chains and inhalation. Estimates of potential dose via the marine food chain were based upon data collected on previous trips to the atoll. The terrestrial pathway contributes the greater percentage, external gamma exposure contributes the next highest, and inhalation and marine pathways contribute minor fractions of the total whole body and bone marrow doses. The radionuclides contributing the major fraction of the dose are 90 Sr and 137 Cs. All living patterns involving Bikini Island exceed federal guidelines for 30-yr population doses. The Eneu Island living pattern leads to doses that are slightly less than federal guidelines. All patterns evaluated for Bikini Atoll lead to higher doses than those on the southern islands at Enewetak Atoll

  14. Personnel external dose monitoring system

    International Nuclear Information System (INIS)

    Zhao Hengyuan

    1989-01-01

    The status and trend of personnel external dose monitoring system are introduced briefly. Their characteristics, functions and TLD bedges of some commercially available automatic TLD system, including UD-710A (Matsushita, Japan), Harshaw-2271, 2276 (Harshaw, USA), Harshaw-8000 (Harshaw/Filtrol), Studsvik-1313 (Sweden) and Pitman-800 (UK) were depicted in detail. Finally, personnel dose management and record keeping system were presented and two examples were given

  15. Dose evaluation and protection of cosmic radiation

    International Nuclear Information System (INIS)

    Iwai, Satoshi; Takagi, Toshiharu

    2004-01-01

    This paper explained the effects of cosmic radiation on aircraft crews and astronauts, as well as related regulations. International Commission on Radiological Protection (ICRP) recommends the practice of radiation exposure management for the handling/storage of radon and materials containing natural radioactive substances, as well as for boarding jet aircraft and space flight. Common aircraft crew members are not subject to radiation exposure management in the USA and Japan. In the EU, the limit value is 6 mSv per year, and for the crew group exceeding this value, it is recommended to keep records containing appropriate medical examination results. Pregnant female crewmembers are required to keep an abdominal surface dose within 1 mSv. For astronauts, ICRP is in the stage of thinking about exposure management. In the USA, National Council on Radiation Protection and Measurement has set dose limits for 30 days, 1 year, and lifetime, and recommends lifetime effective dose limits against carcinogenic risk for each gender and age group. This is the setting of the dose limits so that the risk of carcinogenesis, to which space radiation exposure is considered to contribute, will reach 3%. For cosmic radiation environments at spacecraft inside and aircraft altitude, radiation doses can be calculated for astronauts and crew members, using the calculation methods for effective dose and dose equivalent for tissue. (A.O.)

  16. Monte Carlo simulations of the secondary neutron ambient and effective dose equivalent rates from surface to suborbital altitudes and low Earth orbit.

    Science.gov (United States)

    El-Jaby, Samy; Richardson, Richard B

    2015-07-01

    Occupational exposures from ionizing radiation are currently regulated for airline travel (Earth orbit (∼300-400 km). Aircrew typically receive between 1 and 6 mSv of occupational dose annually, while aboard the International Space Station, the area radiation dose equivalent measured over just 168 days was 106 mSv at solar minimum conditions. It is anticipated that space tourism vehicles will reach suborbital altitudes of approximately 100 km and, therefore, the annual occupational dose to flight crew during repeated transits is expected to fall somewhere between those observed for aircrew and astronauts. Unfortunately, measurements of the radiation environment at the high altitudes reached by suborbital vehicles are sparse, and modelling efforts have been similarly limited. In this paper, preliminary MCNPX radiation transport code simulations are developed of the secondary neutron flux profile in air from surface altitudes up to low Earth orbit at solar minimum conditions and excluding the effects of spacecraft shielding. These secondary neutrons are produced by galactic cosmic radiation interacting with Earth's atmosphere and are among the sources of radiation that can pose a health risk. Associated estimates of the operational neutron ambient dose equivalent, used for radiation protection purposes, and the neutron effective dose equivalent that is typically used for estimates of stochastic health risks, are provided in air. Simulations show that the neutron radiation dose rates received at suborbital altitudes are comparable to those experienced by aircrew flying at 7 to 14 km. We also show that the total neutron dose rate tails off beyond the Pfotzer maximum on ascension from surface up to low Earth orbit. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  17. Weldon Spring historical dose estimate

    International Nuclear Information System (INIS)

    Meshkov, N.; Benioff, P.; Wang, J.; Yuan, Y.

    1986-07-01

    This study was conducted to determine the estimated radiation doses that individuals in five nearby population groups and the general population in the surrounding area may have received as a consequence of activities at a uranium processing plant in Weldon Spring, Missouri. The study is retrospective and encompasses plant operations (1957-1966), cleanup (1967-1969), and maintenance (1969-1982). The dose estimates for members of the nearby population groups are as follows. Of the three periods considered, the largest doses to the general population in the surrounding area would have occurred during the plant operations period (1957-1966). Dose estimates for the cleanup (1967-1969) and maintenance (1969-1982) periods are negligible in comparison. Based on the monitoring data, if there was a person residing continually in a dwelling 1.2 km (0.75 mi) north of the plant, this person is estimated to have received an average of about 96 mrem/yr (ranging from 50 to 160 mrem/yr) above background during plant operations, whereas the dose to a nearby resident during later years is estimated to have been about 0.4 mrem/yr during cleanup and about 0.2 mrem/yr during the maintenance period. These values may be compared with the background dose in Missouri of 120 mrem/yr

  18. Technical basis for dose reconstruction

    International Nuclear Information System (INIS)

    Anspaugh, L.R.

    1996-01-01

    The purpose of this paper is to consider two general topics: Technical considerations of why dose-reconstruction studies should or should not be performed and methods of dose reconstruction. The first topic is of general and growing interest as the number of dose-reconstruction studies increases, and one asks the question whether it is necessary to perform a dose reconstruction for virtually every site at which, for example, the Department of Energy (DOE) has operated a nuclear-related facility. And there is the broader question of how one might logically draw the line at performing or not performing dose-reconstruction (radiological and chemical) studies for virtually every industrial complex in the entire country. The second question is also of general interest. There is no single correct way to perform a dose-reconstruction study, and it is important not to follow blindly a single method to the point that cheaper, faster, more accurate, and more transparent methods might not be developed and applied. 90 refs., 4 tabs

  19. Weldon Spring historical dose estimate

    Energy Technology Data Exchange (ETDEWEB)

    Meshkov, N.; Benioff, P.; Wang, J.; Yuan, Y.

    1986-07-01

    This study was conducted to determine the estimated radiation doses that individuals in five nearby population groups and the general population in the surrounding area may have received as a consequence of activities at a uranium processing plant in Weldon Spring, Missouri. The study is retrospective and encompasses plant operations (1957-1966), cleanup (1967-1969), and maintenance (1969-1982). The dose estimates for members of the nearby population groups are as follows. Of the three periods considered, the largest doses to the general population in the surrounding area would have occurred during the plant operations period (1957-1966). Dose estimates for the cleanup (1967-1969) and maintenance (1969-1982) periods are negligible in comparison. Based on the monitoring data, if there was a person residing continually in a dwelling 1.2 km (0.75 mi) north of the plant, this person is estimated to have received an average of about 96 mrem/yr (ranging from 50 to 160 mrem/yr) above background during plant operations, whereas the dose to a nearby resident during later years is estimated to have been about 0.4 mrem/yr during cleanup and about 0.2 mrem/yr during the maintenance period. These values may be compared with the background dose in Missouri of 120 mrem/yr.

  20. Technical basis for dose reconstruction

    International Nuclear Information System (INIS)

    Anspaugh, L.R.

    1996-01-01

    The purpose of this paper is to consider two general topics: technical considerations of why dose-reconstruction studies should or should not be performed and methods of dose reconstruction. The first topic is of general and growing interest as the number of dose-reconstruction studies increases, and one asks the question whether it is necessary to perform a dose reconstruction for virtually every site at which, for example, the Department of Energy (DOE) has operated a nuclear-related facility. And there is the broader question of how one might logically draw the line at performing or not performing dose-reconstruction (radiological and chemical) studies for virtually every industrial complex in the entire country. The second question is also of general interest. There is no single correct way to perform a dose-reconstruction study, and it is important not to follow blindly a single method to the point that cheaper, faster, more accurate, and more transparent methods might not be developed and applied

  1. Measurement of entrance surface dose on an anthropomorphic thorax phantom using a miniature fiber-optic dosimeter.

    Science.gov (United States)

    Yoo, Wook Jae; Shin, Sang Hun; Jeon, Dayeong; Hong, Seunghan; Sim, Hyeok In; Kim, Seon Geun; Jang, Kyoung Won; Cho, Seunghyun; Youn, Won Sik; Lee, Bongsoo

    2014-04-01

    A miniature fiber-optic dosimeter (FOD) system was fabricated using a plastic scintillating fiber, a plastic optical fiber, and a multi-pixel photon counter to measure real-time entrance surface dose (ESD) during radiation diagnosis. Under varying exposure parameters of a digital radiography (DR) system, we measured the scintillating light related to the ESD using the sensing probe of the FOD, which was placed at the center of the beam field on an anthropomorphic thorax phantom. Also, we obtained DR images using a flat panel detector of the DR system to evaluate the effects of the dosimeter on image artifacts during posteroanterior (PA) chest radiography. From the experimental results, the scintillation output signals of the FOD were similar to the ESDs including backscatter simultaneously obtained using a semiconductor dosimeter. We demonstrated that the proposed miniature FOD can be used to measure real-time ESDs with minimization of DR image artifacts in the X-ray energy range of diagnostic radiology.

  2. Measurement of Entrance Surface Dose on an Anthropomorphic Thorax Phantom Using a Miniature Fiber-Optic Dosimeter

    Directory of Open Access Journals (Sweden)

    Wook Jae Yoo

    2014-04-01

    Full Text Available A miniature fiber-optic dosimeter (FOD system was fabricated using a plastic scintillating fiber, a plastic optical fiber, and a multi-pixel photon counter to measure real-time entrance surface dose (ESD during radiation diagnosis. Under varying exposure parameters of a digital radiography (DR system, we measured the scintillating light related to the ESD using the sensing probe of the FOD, which was placed at the center of the beam field on an anthropomorphic thorax phantom. Also, we obtained DR images using a flat panel detector of the DR system to evaluate the effects of the dosimeter on image artifacts during posteroanterior (PA chest radiography. From the experimental results, the scintillation output signals of the FOD were similar to the ESDs including backscatter simultaneously obtained using a semiconductor dosimeter. We demonstrated that the proposed miniature FOD can be used to measure real-time ESDs with minimization of DR image artifacts in the X-ray energy range of diagnostic radiology.

  3. Association between cumulative radiation dose, adverse skin reactions, and changes in surface hemoglobin among women undergoing breast conserving therapy

    Directory of Open Access Journals (Sweden)

    Michael S. Chin

    2017-06-01

    Conclusion: HSI demonstrates promise in the assessment of skin dose as well as an objective measure of skin reaction. The ability to easily identify adverse skin reactions and to modify the treatment plan may circumvent the need for detrimental treatment breaks.

  4. Patient dose in digital mammography

    International Nuclear Information System (INIS)

    Chevalier, Margarita; Moran, Pilar; Ten, Jose I.; Fernandez Soto, Jose M.; Cepeda, T.; Vano, Eliseo

    2004-01-01

    In the present investigation, we analyze the dose of 5034 patients (20 137 images) who underwent mammographic examinations with a full-field digital mammography system. Also, we evaluate the system calibration by analyzing the exposure factors as a function of breast thickness. The information relevant to this study has been extracted from the image DICOM header and stored in a database during a 3-year period (March 2001-October 2003). Patient data included age, breast thickness, kVp, mAs, target/filter combination, and nominal dose values. Entrance surface air kerma (ESAK) without backscatter was calculated from the tube output as measured for each voltage used under clinical conditions and from the tube loading (mAs) included in the DICOM header. Mean values for the patient age and compressed breast thickness were 56 years (SD: 11) and 52 mm (SD: 13), respectively. The majority of the images was acquired using the STD (for standard) automatic mode (98%). The most frequent target/filter combination automatically selected for breast smaller than 35 mm was Mo/Mo (75%); for intermediate thicknesses between 35 and 65 mm, the combinations were Mo/Rh (54%) and Rh/Rh (38.5%); Rh/Rh was the combination selected for 91% of the cases for breasts thicker than 65 mm. A wide kVp range was observed for each target/filter combination. The most frequent values were 28 kVp for Mo/Mo, 29 kVp for Mo/Rh, and 29 and 30 kV for Rh/Rh. Exposure times ranged from 0.2 to 4.2 s with a mean value of 1.1 s. Average glandular doses (AGD) per exposure were calculated by multiplying the ESAK values by the conversion factors tabulated by Dance for women in the age groups 50 to 64 and 40 to 49. This approach is based on the dependence of breast glandularity on breast thickness and age. The total mean average glandular dose (AGD T ) was calculated by summing the values associated with the pre-exposure and with the main exposure. Mean AGD T per exposure was 1.88 mGy (CI 0.01) and the mean AGD T per

  5. Dose assessments for SFR 1

    International Nuclear Information System (INIS)

    Bergstroem, Ulla; Avila, Rodolfo; Ekstroem, Per-Anders; Cruz, Idalmis de la

    2008-05-01

    Following a review by the Swedish regulatory authorities of the safety analysis of the SFR 1 disposal facility for low and intermediate level waste, SKB has prepared an updated safety analysis, SAR-08. This report presents estimations of annual doses to the most exposed groups from potential radionuclide releases from the SFR 1 repository for a number of calculation cases, selected using a systematic approach for identifying relevant scenarios for the safety analysis. The dose estimates can be used for demonstrating that the long term safety of the repository is in compliance with the regulatory requirements. In particular, the mean values of the annual doses can be used to estimate the expected risks to the most exposed individuals, which can then be compared with the regulatory risk criteria for human health. The conversion from doses to risks is performed in the main report. For one scenario however, where the effects of an earthquake taking place close to the repository are analysed, risk calculations are presented in this report. In addition, prediction of concentrations of radionuclides in environmental media, such as water and soil, are compared with concentration limits suggested by the Erica-project as a base for estimating potential effects on the environment. The assessment of the impact on non-human biota showed that the potential impact is negligible. Committed collective dose for an integration period of 10,000 years for releases occurring during the first thousand years after closure are also calculated. The collective dose commitment was estimated to be 8 manSv. The dose calculations were carried out for a period of 100,000 years, which was sufficient to observe peak doses in all scenarios considered. Releases to the landscape and to a well were considered. The peaks of the mean annual doses from releases to the landscape are associated with C-14 releases to a future lake around year 5,000 AD. In the case of releases to a well, the peak annual doses

  6. Dose assessments for SFR 1

    Energy Technology Data Exchange (ETDEWEB)

    Bergstroem, Ulla (Swedish Nuclear Fuel and Waste Management Co., Stockholm (Sweden)); Avila, Rodolfo; Ekstroem, Per-Anders; Cruz, Idalmis de la (Facilia AB, Bromma (Sweden))

    2008-06-15

    Following a review by the Swedish regulatory authorities of the safety analysis of the SFR 1 disposal facility for low and intermediate level waste, SKB has prepared an updated safety analysis, SAR-08. This report presents estimations of annual doses to the most exposed groups from potential radionuclide releases from the SFR 1 repository for a number of calculation cases, selected using a systematic approach for identifying relevant scenarios for the safety analysis. The dose estimates can be used for demonstrating that the long term safety of the repository is in compliance with the regulatory requirements. In particular, the mean values of the annual doses can be used to estimate the expected risks to the most exposed individuals, which can then be compared with the regulatory risk criteria for human health. The conversion from doses to risks is performed in the main report. For one scenario however, where the effects of an earthquake taking place close to the repository are analysed, risk calculations are presented in this report. In addition, prediction of concentrations of radionuclides in environmental media, such as water and soil, are compared with concentration limits suggested by the Erica-project as a base for estimating potential effects on the environment. The assessment of the impact on non-human biota showed that the potential impact is negligible. Committed collective dose for an integration period of 10,000 years for releases occurring during the first thousand years after closure are also calculated. The collective dose commitment was estimated to be 8 manSv. The dose calculations were carried out for a period of 100,000 years, which was sufficient to observe peak doses in all scenarios considered. Releases to the landscape and to a well were considered. The peaks of the mean annual doses from releases to the landscape are associated with C-14 releases to a future lake around year 5,000 AD. In the case of releases to a well, the peak annual doses

  7. Hanford Environmental Dose Reconstruction Project monthly report

    International Nuclear Information System (INIS)

    McMakin, A.H., Cannon, S.D.; Finch, S.M.

    1992-09-01

    The objective of the Hanford Environmental Dose Reconstruction MDR) Project is to estimate the radiation doses that individuals and populations could have received from nuclear operations at Hanford since 1944. The TSP consists of experts in envirorunental pathways. epidemiology, surface-water transport, ground-water transport, statistics, demography, agriculture, meteorology, nuclear engineering. radiation dosimetry. and cultural anthropology. Included are appointed members representing the states of Oregon, Washington, and Idaho, a representative of Native American tribes, and an individual representing the public. The project is divided into the following technical tasks. These tasks correspond to the path radionuclides followed from release to impact on humans (dose estimates): Source Terms; Environmental Transport; Environmental Monitoring Data Demography, Food Consumption, and Agriculture; and Environmental Pathways and Dose Estimates

  8. Doses from Hiroshima mass radiologic gastric surveys

    Energy Technology Data Exchange (ETDEWEB)

    Antoku, S; Sawada, S; Russell, W J [Radiation Effects Research Foundation, Hiroshima (Japan)

    1980-05-01

    Doses to examinees from mass radiologic surveys of the stomach in Hiroshima Perfecture were estimated by surveying for the frequency of the examinations, and for the technical factors used in them, and by phantom dosimetry. The average surface, active bone marrow and male and female gonad doses per examination were 5.73 rad, 231 mrad, and 20.6 and 140 mrad, respectively. These data will be used in estimating doses from medical X-rays among atomic bomb survivors. By applying them to the Hiroshima population, the genetically significant, per caput mean marrow, and leukemia significant doses were 0.14,8.6 and 7.4 mrad, respectively. There was a benefit-to risk ratio of about 50 for mass gastric surveys performed in 1976. However, the calculated risk was greater than the benefit for examinees under 29 years of age because of the lower incidence of gastric cancer in those under 29 years.

  9. Estimation of Absorbed Dose in Occlusal Radiography

    International Nuclear Information System (INIS)

    Yoo, Young Ah; Choi, Karp Shick; Lee, Sang Han

    1990-01-01

    The purpose of this study was to estimate absorbed dose of each important anatomic site of phantom (RT-210 Head and Neck Section R, Humanoid Systems Co., U.S.A.) head in occlusal radiography. X-radiation dosimetry at 12 anatomic sites in maxillary anterior topography, maxillary posterior topography, mandibular anterior cross-section, mandibular posterior cross-section, mandibular anterior topographic, mandibular posterior topographic occlusal projection was performed with calcium sulfate thermoluminescent dosimeters under 70 Kvp and 15 mA, 1/4 second (8 inch cone ) and 1 second (16 inch cone) exposure time. The results obtained were as follows: Skin surface produced highest absorbed dose ranged between 3264 mrad and 4073 mrad but there was little difference between projections. In maxillary anterior topographic occlusal radiography, eyeballs, maxillary sinuses, and pituitary gland sites produced higher absorbed doses than those of other sites. In maxillary posterior topographic occlusal radiography, exposed eyeball site and exposed maxillary sinus site produced high absorbed doses. In mandibular anterior cross-sectional occlusal radiography, all sites were produced relatively low absorbed dose except eyeball sites. In Mandibular posterior cross-sectional occlusal radiography, exposed eyeball site and exposed maxillary sinus site were produced relatively higher absorbed doses than other sites. In mandibular anterior topographic occlusal radiography, maxillary sinuses, submandibular glands, and thyroid gland sites produced high absorbed doses than other sites. In mandibular posterior topographic occlusal radiography, submandibular gland site of the exposed side produced high absorbed dose than other sites and eyeball site of the opposite side produced relatively high absorbed dose.

  10. Evaluation of surface radiation dose to the thyroid gland and the gonads during routine full-mouth intraoral periapical and maxillary occlusal radiography

    Directory of Open Access Journals (Sweden)

    Soheyl Sheikh

    2010-01-01

    Full Text Available Aim: The quantitative aspects of radiation doses to critical organs can help the dental professionals to take the necessary radiation protective measures as deemed necessary and can help the general public to allay radiation exposure fear in dental radiography, if any. Our study determines the surface radiation dose to thyroid and gonads in full-mouth intraoral periapical (IOPA and maxillary occlusal radiography.Materials and Methods: A total number of 120 subjects participated in the study. The surface radiation dose was estimated to the thyroid gland and the gonads in full-mouth IOPA radiography using 10 IOPA (E speed films and in maxillary occlusal radiography. The measurements were calculated using a digital pocket dosimeter (PD-4507.Results: The average dose at the thyroid gland level during full-mouth intraoral and maxillary occlusal radiography was estimated to be 10.93 mRads (1.093 Χ 10 -2 mGy and 0.4 mRads (4.0 Χ 10 -2 mGy, respectively. The average surface radiation dose at the gonadal region during a full mouth intraoral and maxillary occlusal radiography was estimated to be 1.5 mRads (1.5 Χ 10 -2 mGy and 0.15 mRads (1.5 Χ 10 -3 mGy, respectively. Conclusion: Our results suggest that although the radiation exposure doses to critical organs namely thyroid and gonads is within the safe limits still precautionary measures for these organs are advocated.

  11. Radiation dose monitoring in the clinical routine

    Energy Technology Data Exchange (ETDEWEB)

    Guberina, Nika [UK Essen (Germany). Radiology

    2017-04-15

    Here we describe the first clinical experiences regarding the use of an automated radiation dose management software to monitor the radiation dose of patients during routine examinations. Many software solutions for monitoring radiation dose have emerged in the last decade. The continuous progress in radiological techniques, new scan features, scanner generations and protocols are the primary challenge for radiation dose monitoring software systems. To simulate valid dose calculations, radiation dose monitoring systems have to follow current trends and stay constantly up-to-date. The dose management software is connected to all devices at our institute and conducts automatic data acquisition and radiation dose calculation. The system incorporates 18 virtual phantoms based on the Cristy phantom family, estimating doses in newborns to adults. Dose calculation relies on a Monte Carlo simulation engine. Our first practical experiences demonstrate that the software is capable of dose estimation in the clinical routine. Its implementation and use have some limitations that can be overcome. The software is promising and allows assessment of radiation doses, like organ and effective doses according to ICRP 60 and ICRP 103, patient radiation dose history and cumulative radiation doses. Furthermore, we are able to determine local diagnostic reference doses. The radiation dose monitoring software systems can facilitate networking between hospitals and radiological departments, thus refining radiation doses and implementing reference doses at substantially lower levels.

  12. Low-dose dental CT

    International Nuclear Information System (INIS)

    Rustemeyer, P.; Eich, H.T.; John-Mikolajewski, V.; Mueller, R.D.

    1999-01-01

    Purpose: The intention of this study was to reduce patient dose during dental CT in the planning for osseointegrated implants. Methods and Materials: Dental CTs were performed with a spiral CT (Somatom Plus 4, Siemens) and a dental software package. Use of the usual dental CT technique (120 kVp; 165 mA, 1 s rotation time, 165 mAs; pitch factor 1) was compared with a new protocol (120 kVp; 50 mA; 0.7 s rotation time; 35 mAs; pitch factor 2) which delivered the best image quality at the lowest possible radiation dose, as tested in a preceding study. Image quality was analysed using a human anatomic head preparation. Four radiologists analysed the images independently. A Wilcoxon rank pair-test was used for statistic evaluation. The doses to the thyroid gland, the active bone marrow, the salivary glands, and the eye lens were determined in a tissue-equivalent phantom (Alderson-Rando Phantom) with lithium fluoride thermoluminescent dosimeters at the appropriate locations. Results: By mAs reduction from 165 to 35 and using a pitch factor of 2, the radiation dose could be reduced by a factor of nine (max.) (e.g., the bone marrow dose could be reduced from 23.6 mSv to 2.9 mSv, eye lens from 0.5 mSv to 0.3 mSv, thyroid gland from 2.5 mSv to 0.5 mSv, parotid glands from 2.3 mSv to 0.4 mSv). The dose reduction did not lead to an actual loss of image quality or diagnostic information. Conclusion: A considerable dose reduction without loss of diagnostic information is achievable in dental CT. Dosereducing examination protocols like the one presented may further expand the use of preoperative dental CT. (orig.) [de

  13. Patient and staff doses in interventional neuroradiology

    International Nuclear Information System (INIS)

    Bor, D.; Cekirge, S.; Tuerkay, T.; Turan, O.; Guelay, M.; Oenal, E.; Cil, B.

    2005-01-01

    Radiation doses for interventional examinations are generally high and therefore necessitate dose monitoring for patients and staff. Relating the staff dose to a patient dose index, such as dose-area product (DAP), could be quite useful for dose comparisons. In this study, DAP and skin doses of 57 patients, who underwent neuro-interventional examinations, were measured simultaneously with staff doses. Although skin doses were comparable with the literature data, higher DAP values of 215 and 188.6 Gy cm 2 were measured for the therapeutical cerebral and carotid examinations, respectively, owing to the use of biplane system and complexity of the procedure. Mean staff doses for eye, finger and thyroid were measured as 80.6, 77.6 and 28.8 μGy per procedure. The mean effective dose per procedure for the radiologists was 32 μSv. In order to allow better comparisons to be made, DAP normalised doses were also presented. (authors)

  14. Repair and dose-response at low doses

    International Nuclear Information System (INIS)

    Totter, J.R.; Weinberg, A.M.

    1977-04-01

    The DNA of each individual is subject to formation of some 2-4 x 10 14 ion pairs during the first 30 years of life from background radiation. If a single hit is sufficient to cause cancer, as is implicit in the linear, no-threshold theories, it is unclear why all individuals do not succumb to cancer, unless repair mechanisms operate to remove the damage. We describe a simple model in which the exposed population displays a distribution of repair thresholds. The dose-response at low dose is shown to depend on the shape of the threshold distribution at low thresholds. If the probability of zero threshold is zero, the response at low dose is quadratic. The model is used to resolve a longstanding discrepancy between observed incidence of leukemia at Nagasaki and the predictions of the usual linear hypothesis

  15. Build-up and surface dose measurements on phantoms using micro-MOSFET in 6 and 10 MV x-ray beams and comparisons with Monte Carlo calculations

    International Nuclear Information System (INIS)

    Xiang, Hong F.; Song, Jun S.; Chin, David W. H.; Cormack, Robert A.; Tishler, Roy B.; Makrigiorgos, G. Mike; Court, Laurence E.; Chin, Lee M.

    2007-01-01

    This work is intended to investigate the application and accuracy of micro-MOSFET for superficial dose measurement under clinically used MV x-ray beams. Dose response of micro-MOSFET in the build-up region and on surface under MV x-ray beams were measured and compared to Monte Carlo calculations. First, percentage-depth-doses were measured with micro-MOSFET under 6 and 10 MV beams of normal incidence onto a flat solid water phantom. Micro-MOSFET data were compared with the measurements from a parallel plate ionization chamber and Monte Carlo dose calculation in the build-up region. Then, percentage-depth-doses were measured for oblique beams at 0 deg. - 80 deg. onto the flat solid water phantom with micro-MOSFET placed at depths of 2 cm, 1 cm, and 2 mm below the surface. Measurements were compared to Monte Carlo calculations under these settings. Finally, measurements were performed with micro-MOSFET embedded in the first 1 mm layer of bolus placed on a flat phantom and a curved phantom of semi-cylindrical shape. Results were compared to superficial dose calculated from Monte Carlo for a 2 mm thin layer that extends from the surface to a depth of 2 mm. Results were (1) Comparison of measurements with MC calculation in the build-up region showed that micro-MOSFET has a water-equivalence thickness (WET) of 0.87 mm for 6 MV beam and 0.99 mm for 10 MV beam from the flat side, and a WET of 0.72 mm for 6 MV beam and 0.76 mm for 10 MV beam from the epoxy side. (2) For normal beam incidences, percentage depth dose agree within 3%-5% among micro-MOSFET measurements, parallel-plate ionization chamber measurements, and MC calculations. (3) For oblique incidence on the flat phantom with micro-MOSFET placed at depths of 2 cm, 1 cm, and 2 mm, measurements were consistent with MC calculations within a typical uncertainty of 3%-5%. (4) For oblique incidence on the flat phantom and a curved-surface phantom, measurements with micro-MOSFET placed at 1.0 mm agrees with the MC

  16. Notes on the effect of dose uncertainty

    International Nuclear Information System (INIS)

    Morris, M.D.

    1987-01-01

    The apparent dose-response relationship between amount of exposure to acute radiation and level of mortality in humans is affected by uncertainties in the dose values. It is apparent that one of the greatest concerns regarding the human data from Hiroshima and Nagasaki is the unexpectedly shallow slope of the dose response curve. This may be partially explained by uncertainty in the dose estimates. Some potential effects of dose uncertainty on the apparent dose-response relationship are demonstrated

  17. Trends in population dose and examples of occupational dose reduction

    International Nuclear Information System (INIS)

    Shaw, K.B.; Hughes, J.S.; McDonough, L.; Gelder, R.

    1989-01-01

    The recent review by NRPB of the exposure of the UK population shows the average annual dose to the population from all sources of radiation to be 2.5 mSv(1). Natural radiation gives rise to 87% of this with radon daughters accounting for the largest single contribution of 1.2 mSv. Medical irradiation remains the most significant contributor to the dose from man-made sources: the current estimate for all diagnostic uses is 0.3 mSv per annum. (author)

  18. Peripheral doses from pediatric IMRT

    International Nuclear Information System (INIS)

    Klein, Eric E.; Maserang, Beth; Wood, Roy; Mansur, David

    2006-01-01

    Peripheral dose (PD) data exist for conventional fields (≥10 cm) and intensity-modulated radiotherapy (IMRT) delivery to standard adult-sized phantoms. Pediatric peripheral dose reports are limited to conventional therapy and are model based. Our goal was to ascertain whether data acquired from full phantom studies and/or pediatric models, with IMRT treatment times, could predict Organ at Risk (OAR) dose for pediatric IMRT. As monitor units (MUs) are greater for IMRT, it is expected IMRT PD will be higher; potentially compounded by decreased patient size (absorption). Baseline slab phantom peripheral dose measurements were conducted for very small field sizes (from 2 to 10 cm). Data were collected at distances ranging from 5 to 72 cm away from the field edges. Collimation was either with the collimating jaws or the multileaf collimator (MLC) oriented either perpendicular or along the peripheral dose measurement plane. For the clinical tests, five patients with intracranial or base of skull lesions were chosen. IMRT and conventional three-dimensional (3D) plans for the same patient/target/dose (180 cGy), were optimized without limitation to the number of fields or wedge use. Six MV, 120-leaf MLC Varian axial beams were used. A phantom mimicking a 3-year-old was configured per Center for Disease Control data. Micro (0.125 cc) and cylindrical (0.6 cc) ionization chambers were appropriated for the thyroid, breast, ovaries, and testes. The PD was recorded by electrometers set to the 10 -10 scale. Each system set was uniquely calibrated. For the slab phantom studies, close peripheral points were found to have a higher dose for low energy and larger field size and when MLC was not deployed. For points more distant from the field edge, the PD was higher for high-energy beams. MLC orientation was found to be inconsequential for the small fields tested. The thyroid dose was lower for IMRT delivery than that predicted for conventional (ratio of IMRT/cnventional ranged from

  19. AGING FACILITY WORKER DOSE ASSESSMENT

    International Nuclear Information System (INIS)

    R.L. Thacker

    2005-01-01

    The purpose of this calculation is to estimate radiation doses received by personnel working in the Aging Facility performing operations to transfer aging casks to the aging pads for thermal and logistical management, stage empty aging casks, and retrieve aging casks from the aging pads for further processing in other site facilities. Doses received by workers due to aging cask surveillance and maintenance operations are also included. The specific scope of work contained in this calculation covers both collective doses and individual worker group doses on an annual basis, and includes the contributions due to external and internal radiation from normal operation. There are no Category 1 event sequences associated with the Aging Facility (BSC 2004 [DIRS 167268], Section 7.2.1). The results of this calculation will be used to support the design of the Aging Facility and to provide occupational dose estimates for the License Application. The calculations contained in this document were developed by Environmental and Nuclear Engineering of the Design and Engineering Organization and are intended solely for the use of the Design and Engineering Organization in its work regarding facility operation. Yucca Mountain Project personnel from the Environmental and Nuclear Engineering should be consulted before use of the calculations for purposes other than those stated herein or use by individuals other than authorized personnel in Environmental and Nuclear Engineering

  20. Evaluation of occupational and patient radiation doses in orthopedic surgery

    International Nuclear Information System (INIS)

    Sulieman, A.; Alzimami, K.; Habeeballa, B.; Osman, H.; Abdelaziz, I.; Sassi, S.A.; Sam, A.K.

    2015-01-01

    This study intends to measure the radiation dose to patients and staff during (i) Dynamic Hip Screw (DHS) and (ii) Dynamic Cannula Screw (DCS) and to evaluate entrance surface Air kerma (ESAK) dose and organ doses and effective doses. Calibrated Thermoluminescence dosimeters (TLD-GR200A) were used. The mean patients’ doses were 0.46 mGy and 0.07 mGy for DHS and DCS procedures, respectively. The mean staff doses at the thyroid and chest were 4.69 mGy and 1.21 mGy per procedure. The mean organ and effective dose for patients and staff were higher in DHS compared to DCS. Orthopedic surgeons were exposed to unnecessary radiation doses due to the lack of protection measures. The radiation dose per hip procedure is within the safety limit and less than the previous studies

  1. A practical approach to determine dose metrics for nanomaterials.

    Science.gov (United States)

    Delmaar, Christiaan J E; Peijnenburg, Willie J G M; Oomen, Agnes G; Chen, Jingwen; de Jong, Wim H; Sips, Adriënne J A M; Wang, Zhuang; Park, Margriet V D Z

    2015-05-01

    Traditionally, administered mass is used to describe doses of conventional chemical substances in toxicity studies. For deriving toxic doses of nanomaterials, mass and chemical composition alone may not adequately describe the dose, because particles with the same chemical composition can have completely different toxic mass doses depending on properties such as particle size. Other dose metrics such as particle number, volume, or surface area have been suggested, but consensus is lacking. The discussion regarding the most adequate dose metric for nanomaterials clearly needs a systematic, unbiased approach to determine the most appropriate dose metric for nanomaterials. In the present study, the authors propose such an approach and apply it to results from in vitro and in vivo experiments with silver and silica nanomaterials. The proposed approach is shown to provide a convenient tool to systematically investigate and interpret dose metrics of nanomaterials. Recommendations for study designs aimed at investigating dose metrics are provided. © 2015 SETAC.

  2. Survey of Gamma Dose and Radon Exhalation Rate from Soil Surface of High Background Natural Radiation Areas in Ramsar, Iran

    Directory of Open Access Journals (Sweden)

    Rouhollah Dehghani

    2013-09-01

    Full Text Available Background: Radon is a radioactive gas and the second leading cause of death due to lung cancer after smoking. Ramsar is known for having the highest levels of natural background radiation on earth. Materials and Methods: In this research study, 50 stations of high radioactivity areas of Ramsar were selected in warm season of the year. Then gamma dose and radon exhalation rate were measured.Results: Results showed that gamma dose and radon exhalation rate were in the range of 51-7100 nSv/hr and 9-15370 mBq/m2s, respectively.Conclusion: Compare to the worldwide average 16 mBq/m2s, estimated average annual effective of Radon exhalation rate in the study area is too high.

  3. Immunological network activation by low-dose rate irradiation. Analysis of cell populations and cell surface molecules in whole body irradiated mice

    International Nuclear Information System (INIS)

    Ina, Yasuhiro; Sakai, Kazuo

    2003-01-01

    The effects of low-dose rate whole body irradiation on biodefense and immunological systems were investigated using female C57BL/6 (B6) mice. These B6 mice were exposed continuously to γ-rays from a 137 Cs source in the long-term low-dose rate irradiation facility at CRIEPI for 0 - 12 weeks at a dose rate of 0.95 mGy/hr. In the bone marrow, thymus, spleen, lymph nodes, and peripheral blood of the irradiated mice, changes in cell populations and cell surface molecules were examined. The cell surface functional molecules (CD3, CD4, CD8, CD19, CD45R/B220, ICAM-1, Fas, NK-1.1, CXCR4, and CCR5), and activation molecules (THAM, CD28, CD40, CD44H, CD70, B7-1, B7-2, OX-40 antigen, CTLA-4, CD30 ligand, and CD40 ligand) were analyzed by flow cytometry. The percentage of CD4 + T cells and cell surface CD8 molecule expressions on the CD8 + T cells increased significantly to 120-130% after 3 weeks of the irradiation, compared to non-irradiated control mice. On the other hand, the percentage of CD45R/B220 + CD40 + B cells, which is one of the immunological markers of inflammation, infection, tumor, and autoimmune disease, decreased significantly to 80-90% between the 3rd to 5th week of irradiation. There was no significant difference in other cell population rates and cell surface molecule expression. Furthermore, abnormal T cells bearing mutated T cell receptors induced by high-dose rate irradiation were not observed throughout this study. These results suggest that low-dose rate irradiation activates the immunological status of the whole body. (author)

  4. Field size and dose distribution of electron beam

    International Nuclear Information System (INIS)

    Kang, Wee Saing

    1980-01-01

    The author concerns some relations between the field size and dose distribution of electron beams. The doses of electron beams are measured by either an ion chamber with an electrometer or by film for dosimetry. We analyzes qualitatively some relations; the energy of incident electron beams and depths of maximum dose, field sizes of electron beams and depth of maximum dose, field size and scatter factor, electron energy and scatter factor, collimator shape and scatter factor, electron energy and surface dose, field size and surface dose, field size and central axis depth dose, and field size and practical range. He meets with some results. They are that the field size of electron beam has influence on the depth of maximum dose, scatter factor, surface dose and central axis depth dose, scatter factor depends on the field size and energy of electron beam, and the shape of the collimator, and the depth of maximum dose and the surface dose depend on the energy of electron beam, but the practical range of electron beam is independent of field size

  5. Chloroquine is grossly under dosed in young children with malaria

    DEFF Research Database (Denmark)

    Ursing, Johan; Eksborg, Staffan; Rombo, Lars

    2014-01-01

    BACKGROUND: Plasmodium falciparum malaria is treated with 25 mg/kg of chloroquine (CQ) irrespective of age. Theoretically, CQ should be dosed according to body surface area (BSA). The effect of dosing CQ according to BSA has not been determined but doubling the dose per kg doubled the efficacy...

  6. Physical requirements for measurement of radiation dose and their relationship to personnel dose meter design and use

    International Nuclear Information System (INIS)

    Chabot, G.E. Jr.; Jimenez, M.A.; Skrable, K.W.

    1978-01-01

    This paper stems from the concerns of the authors with both the design of current personnel dose meters and the interpretation of dose information from them in light of the actual physical requirements to measure dose. These concerns have been reinforced and extended following a comparative study of the responses of particular TLD and film systems and as the result of a recent national survey on personnel dosimetry conducted by the authors. Among the major points discussed are the systems available for penetrating and shallow dose assessment, dose meter calibration, the measurement and interpretation of skin dose, and the deficiencies of neutron albedo dose meters for routine personnel use. Calibration considerations address the questions of whether or not a phantom should be used and the difference in interpretation of responses with and without a phantom; the relationship between calculated and measured doses; and electronic equilibrium considerations in the measurement of photon doses. Matters of importance in relation to skin dose measurement include techniques in use to interpret skin dose from dose meter response; the appropriateness of evaluation of the surface dose to the live skin layer versus the average dose to the live skin layer and the limitations and requirements on dose meter design with respect to the dose being evaluated; and the significance of dose meter response in relationship to currently used beta calibration standards. Regarding the use of TLD albedo type neutron dose meters currently available, considerations are extended to the strong energy spectral dependence of the dose meter response and the possibility of making significant over or underestimations of neutron dose equivalent, depending on the calibration techniques used and the spectral quality encountered. (author)

  7. Measurement of radiation dose in dental radiology

    International Nuclear Information System (INIS)

    Helmrot, E.; Carlsson, G. A.

    2005-01-01

    Patient dose audit is an important tool for quality control and it is important to have a well-defined and easy to use method for dose measurements. In dental radiology, the most commonly used dose parameters for the setting of diagnostic reference levels (DRLs) are the entrance surface air kerma (ESAK) for intraoral examinations and dose width product (DWP) for panoramic examinations. DWP is the air kerma at the front side of the secondary collimator integrated over the collimator width and an exposure cycle. ESAK or DWP is usually measured in the absence of the patient but with the same settings of tube voltage (kV), tube current (mA) and exposure time as with the patient present. Neither of these methods is easy to use, and, in addition, DWP is not a risk related quantity. A better method of monitoring patient dose would be to use a dose area product (DAP) meter for all types of dental examinations. In this study, measurements with a DAP meter are reported for intraoral and panoramic examinations. The DWP is also measured with a pencil ionisation chamber and the product of DWP and the height H (DWP x H) of the secondary collimator (measured using film) was compared to DAP. The results show that it is feasible to measure DAP using a DAP meter for both intraoral and panoramic examinations. The DAP is therefore recommended for the setting of DRLs. (authors)

  8. Bremsstrahlung doses from natural uranium ingots

    International Nuclear Information System (INIS)

    Anderson, J. L.; Hertel, N. E.

    2005-01-01

    In the past, some privately owned commercial facilities in the United States were involved in producing or processing radioactive materials used in the production of atomic weapons. Seven different geometrical objects, representative of the configurations of natural uranium metal potentially encountered by workers at these facilities, are modelled to determine gamma ray and Bremsstrahlung dose rates. The dose rates are calculated using the MCNP5 code and also by using the MICROSHIELD point-kernel code. Both gamma ray and Bremsstrahlung dose rates are calculated and combined to obtain a total dose rate. The two methods were found to be in good agreement despite differences in modelling assumptions and method differences. Computed total dose rates on the surface of these objects ranged from ∼51-84 μSv h -1 and 17-95 μSv h -1 using the MCNP5 and the MICROSHIELD modeling, respectively. The partitioning of the computed dose rates between gamma rays and Bremsstrahlung were the same order of magnitude for each object. (authors)

  9. Bremsstrahlung doses from natural uranium ingots.

    Science.gov (United States)

    Anderson, Jeri L; Hertel, Nolan E

    2005-01-01

    In the past, some privately owned commercial facilities in the United States were involved in producing or processing radioactive materials used in the production of atomic weapons. Seven different geometrical objects, representative of the configurations of natural uranium metal potentially encountered by workers at these facilities, are modelled to determine gamma ray and bremsstrahlung dose rates. The dose rates are calculated using the MCNP5 code and also by using the MICROSHIELD point-kernel code. Both gamma ray and bremsstrahlung dose rates are calculated and combined to obtain a total dose rate. The two methods were found to be in good agreement despite differences in modelling assumptions and method differences. Computed total dose rates on the surface of these objects ranged from approximately 51-84 microSv h(-1) and 17-95 microSv h(-1) using the MCNP5 and the MICROSHIELD modeling, respectively. The partitioning of the computed dose rates between gamma rays and bremsstrahlung were the same order of magnitude for each object.

  10. Radiation dose measurement in gastrointestinal studies

    International Nuclear Information System (INIS)

    Sulieman, A.; Elzaki, M.; Kappas, C.; Theodorou, K.

    2011-01-01

    Barium studies investigations (barium swallow, barium meal and barium enema) are the basic routine radiological examination, where barium sulphate suspension is introduced to enhance image contrast of gastrointestinal tracts. The aim of this study was to quantify the patients' radiation doses during barium studies and to estimate the organ equivalent dose and effective dose with those procedures. A total of 33 investigations of barium studies were measured by using thermoluminescence dosemeters. The result showed that the patient entrance surface doses were 12.6±10, 44.5±49 and 35.7±50 mGy for barium swallow, barium meal, follow through and enema, respectively. Effective doses were 0.2, 0.35 and 1.4 mSv per procedure for barium swallow, meal and enema respectively. Radiation doses were comparable with the previous studies. A written protocol for each procedure will reduce the inter-operator variations and will help to reduce unnecessary exposure. (authors)

  11. Radiation Dose from Reentrant Electrons

    Science.gov (United States)

    Badhwar, G.D.; Cleghorn, T. E.; Watts, J.

    2003-01-01

    In estimating the crew exposures during an EVA, the contribution of reentrant electrons has always been neglected. Although the flux of these electrons is small compared to the flux of trapped electrons, their energy spectrum extends to several GeV compared to about 7 MeV for trapped electrons. This is also true of splash electrons. Using the measured reentrant electron energy spectra, it is shown that the dose contribution of these electrons to the blood forming organs (BFO) is more than 10 times greater than that from the trapped electrons. The calculations also show that the dose-depth response is a very slowly changing function of depth, and thus adding reasonable amounts of additional shielding would not significantly lower the dose to BFO.

  12. Dose reconstruction using mobile phones

    International Nuclear Information System (INIS)

    Beerten, K.; Reekmans, F.; Schroeyers, W.; Lievens, L.; Vanhavere, F.

    2011-01-01

    Electronic components inside mobile phones are regarded as useful tools for accident and retrospective dosimetry using optically stimulated luminescence (OSL) and thermoluminescence. Components inside the devices with suitable properties for luminescence dosimetry include, amongst others, ceramic substrates in resistors, capacitors, transistors and antenna switches. Checking the performance of such devices in dosimetric experiments is a crucial step towards developing a reliable dosimetry system for emergency situations using personal belongings. Here, the results of dose assessment experiments using irradiated mobile phones are reported. It will be shown that simple regenerative dose estimates, derived from various types of components removed from different mobile phone models, are consistent with the given dose, after applying an average fading correction factor. (authors)

  13. Parameterization of solar flare dose

    International Nuclear Information System (INIS)

    Lamarche, A.H.; Poston, J.W.

    1996-01-01

    A critical aspect of missions to the moon or Mars will be the safety and health of the crew. Radiation in space is a hazard for astronauts, especially high-energy radiation following certain types of solar flares. A solar flare event can be very dangerous if astronauts are not adequately shielded because flares can deliver a very high dose in a short period of time. The goal of this research was to parameterize solar flare dose as a function of time to see if it was possible to predict solar flare occurrence, thus providing a warning time. This would allow astronauts to take corrective action and avoid receiving a dose greater than the recommended limit set by the National Council on Radiation Protection and Measurements (NCRP)

  14. Consultative exercise on dose assessments.

    Science.gov (United States)

    Bridges, B A; Parker, T; Simmonds, J R; Sumner, D

    2001-06-01

    A summary is given of a meeting held at Sussex University, UK, in October 2000, which allowed the exchange of ideas on methods of assessment of dose to the public arising from potential authorised radioactive discharges from nuclear sites in the UK. Representatives of groups with an interest in dose assessments were invited, and hence the meeting was called the Consultative Exercise on Dose Assessments (CEDA). Although initiated and funded by the Food Standards Agency, its organisation, and the writing of the report, were overseen by an independent Chairman and Steering Group. The report contains recommendations for improvement in co-ordination between different agencies involved in assessments, on method development and on the presentation of data on assessments. These have been prepared by the Steering Group, and will be taken forward by the Food Standards Agency and other agencies in the UK. The recommendations are included in this memorandum.

  15. The Effect of Low‑Dose Ketamine (Preemptive Dose) on ...

    African Journals Online (AJOL)

    Average dosage of diclofenac suppository and mean time for taking the first dosage of opioids have not statistical difference too (respectively; P = 0.76, P = 0.87). Average dose of pethidine was lesser than placebo statistically. It means, the case group did not take pethidine but this amount was 6 (20%) in the control one (P ...

  16. Carcinogenesis in mice after low doses and dose rates

    International Nuclear Information System (INIS)

    Ullrich, R.L.

    1979-01-01

    The results from the experimental systems reported here indicate that the dose-response curves for tumor induction in various tissues cannot be described by a single model. Furthermore, although the understanding of the mechanisms involved in different systems is incomplete, it is clear that very different mechanisms for induction are involved. For some tumors the mechanism of carcinogenesis may be mainly a result of direct effects on the target cell, perhaps involving one or more mutations. While induction may occur, in many instances, through such direct effects, the eventual expression of the tumor can be influenced by a variety of host factors including endocrine status, competence of the immune system, and kinetics of target and interacting cell populations. In other tumors, indirect effects may play a major role in the initiation or expression of tumors. Some of the hormone-modulated tumors would fall into this class. Despite the complexities of the experimental systems and the lack of understanding of the types of mechanisms involved, in nearly every example the tumorigenic effectiveness per rad of low-LET radiation tends to decrease with decreasing dose rate. For some tumor types the differences may be small or may appear only with very low dose rates, while for others the dose-rate effects may be large

  17. Stereotactic intracranial radiotherapy: Dose prescription

    International Nuclear Information System (INIS)

    Schlienger, M.; Lartigau, E.; Nataf, F.; Mornex, F.; Latorzeff, I.; Lisbona, A.; Mahe, M.

    2012-01-01

    The aim of this article was the study of the successive steps permitting the prescription of dose in stereotactic intracranial radiotherapy, which includes radiosurgery and fractionated stereotactic radiotherapy. The successive steps studied are: the choice of stereotactic intracranial radiotherapy among the therapeutic options, based on curative or palliative treatment intent, then the selection of lesions according to size/volume, pathological type and their number permitting the choice between radiosurgery or fractionated stereotactic radiotherapy, which have the same methodological basis. Clinical experience has determined the level of dose to treat the lesions and limit the irradiation of healthy adjacent tissues and organs at risk structures. The last step is the optimization of the different parameters to obtain a safe compromise between the lesion dose and healthy adjacent structures. Study of dose-volume histograms, coverage indices and 3D imaging permit the optimization of irradiation. For lesions close to or included in a critical area, the prescribed dose is planned using the inverse planing method. Implementation of the successively described steps is mandatory to insure the prescription of an optimized dose. The whole procedure is based on the delineation of the lesion and adjacent healthy tissues. There are sometimes difficulties to assess the delineation and the volume of the target, however improvement of local control rates and reduction of secondary effects are the proof that the totality of the successive procedures are progressively improved. In practice, stereotactic intracranial radiotherapy is a continually improved treatment method, which constantly benefits from improvements in the choice of indications, imaging, techniques of irradiation, planing/optimization methodology and irradiation technique and from data collected from prolonged follow-up. (authors)

  18. Performance standard for dose Calibrator

    CERN Document Server

    Darmawati, S

    2002-01-01

    Dose calibrator is an instrument used in hospitals to determine the activity of radionuclide for nuclear medicine purposes. International Electrotechnical Commission (IEC) has published IEC 1303:1994 standard that can be used as guidance to test the performance of the instrument. This paper briefly describes content of the document,as well as explains the assessment that had been carried out to test the instrument accuracy in Indonesia through intercomparison measurement.Its is suggested that hospitals acquire a medical physicist to perform the test for its dose calibrator. The need for performance standard in the form of Indonesia Standard is also touched.

  19. Dose budget for exposure control

    International Nuclear Information System (INIS)

    Nair, P.S.

    1999-01-01

    Dose budget is an important management tool to effectively control the collective dose incurred in a nuclear facility. The budget represents a set of yardsticks or guidelines for use in controlling the internal activities, involving radiation exposure in the organisation. The management, through budget can evaluate the radiation protection performance at every level of the organisation where a number of independent functional groups work on routine and non-routine jobs. The discrepancy between the plan and the actual performance is high lighted through the budgets. The organisation may have to change the course of its operation in a particular area or revise its plan with due focus on appropriate protective measures. (author)

  20. Natural radiation dose to Gammarus

    International Nuclear Information System (INIS)

    Paschoa, A.S.; Wrenn, M.E.; Eisenbud, M.

    1975-01-01

    The natural radiation dose rate to whole body and components of the Gammarus species (i.e., G. Tigrinus, G. Fasciatus and G. Daiberi) that occurs in the Hudson River is evaluated and the results compared with the upper limits of dose rates from man made sources to the whole body of the organisms. Methods were developed to study the distribution of alpha emitters from 226 Ra plus daughter products in Gammarus using autoradiographic techniques, taking into account the amount of radon that escapes from the organisms. This methodology may be adapted to study the distribution of alpha emitters in contaminated tissues of plants and animals

  1. Confectionery-based dose forms.

    Science.gov (United States)

    Tangso, Kristian J; Ho, Quy Phuong; Boyd, Ben J

    2015-01-01

    Conventional dosage forms such as tablets, capsules and syrups are prescribed in the normal course of practice. However, concerns about patient preferences and market demands have given rise to the exploration of novel unconventional dosage forms. Among these, confectionery-based dose forms have strong potential to overcome compliance problems. This report will review the availability of these unconventional dose forms used in treating the oral cavity and for systemic drug delivery, with a focus on medicated chewing gums, medicated lollipops, and oral bioadhesive devices. The aim is to stimulate increased interest in the opportunities for innovative new products that are available to formulators in this field, particularly for atypical patient populations.

  2. Statistical and low dose response

    International Nuclear Information System (INIS)

    Thorson, M.R.; Endres, G.W.R.

    1981-01-01

    The low dose response and the lower limit of detection of the Hanford dosimeter depend upon may factors, including the energy of the radiation, whether the exposure is to be a single radiation or mixed fields, annealing cycles, environmental factors, and how well various batches of TLD materials are matched in the system. A careful statistical study and sensitivity analysis were performed to determine how these factors influence the response of the dosimeter system. Estimates have been included in this study of the standard deviation of calculated dose for various mixed field exposures from 0 to 1000 mrem

  3. Effective dose equivalents from external radiation due to Chernobyl accident

    International Nuclear Information System (INIS)

    Erkin, V.G.; Debedev, O.V.; Balonov, M.I.; Parkhomenko, V.I.

    1992-01-01

    Summarized data on measurements of individual dose of external γ-sources in 1987-1990 of population of western areas of Bryansk region were presented. Type of distribution of effective dose equivalent, its significance for various professional and social groups of population depending on the type of the house was discussed. Dependences connecting surface soil activity in the populated locality with average dose of external radiation sources were presented. Tendency of dose variation in 1987-1990 was shown

  4. TH-C-12A-10: Surface Dose Enhancement Using Novel Hybrid Electron and Photon Low-Z Therapy Beams: Monte Carlo Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Parsons, C; Parsons, D [Dept of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia (Canada); Robar, J; Kelly, R [Dept of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia (Canada); Dept of Radiation Oncology, Dalhousie University, Halifax, Nova Scotia (Canada); Nova Scotia Cancer Centre, Halifax, NS (Canada)

    2014-06-15

    Purpose: The introduction of the TrueBeam linac platform provides access to an in-air target assembly making it possible to apply novel treatments using multiple target designs. One such novel treatment uses multiple low-Z targets to enhance surface dose replacing the use of synthetic tissue equivalent material (bolus). This treatment technique will decrease the common dosimetric and set up errors prevalent in using physical treatment accessories like bolus. The groundwork for a novel treatment beam used to enhance surface dose to within 80-100% of the dose at dmax by utilizing low-Z (Carbon) targets of various percent CSDA range thickness operated at 2.5–4 MeV used in conjunction with a clinical 6 MV beam is presented herein. Methods: A standard Monte Carlo model of a Varian Clinac accelerator was developed to manufacturers specifications. Simulations were performed using Be, C, AL, and C, as potential low-Z targets, placed in the secondary target position. The results determined C to be the target material of choice. Simulations of 15, 30 and 60% CSDA range C beams were propagated through slab phantoms. The resulting PDDs were weighted and combined with a standard 6 MV treatment beam. Versions of the experimental targets were installed into a 2100C Clinac and the models were validated. Results: Carbon was shown to be the low-Z material of choice for this project. Using combinations of 15, 30, 60% CSDA beams operated at 2.5 and 4 MeV in combination with a standard 6 MV treatment beam the surface dose was shown to be enhanced to within 80–100% the dose at dmax. Conclusion: The modeled low-Z beams were successfully validated using machined versions of the targets. Water phantom measurements and slab phantom simulations show excellent correlation. Patient simulations are now underway to compare the use of bolus with the proposed novel beams. NSERC.

  5. TH-C-12A-10: Surface Dose Enhancement Using Novel Hybrid Electron and Photon Low-Z Therapy Beams: Monte Carlo Simulation

    International Nuclear Information System (INIS)

    Parsons, C; Parsons, D; Robar, J; Kelly, R

    2014-01-01

    Purpose: The introduction of the TrueBeam linac platform provides access to an in-air target assembly making it possible to apply novel treatments using multiple target designs. One such novel treatment uses multiple low-Z targets to enhance surface dose replacing the use of synthetic tissue equivalent material (bolus). This treatment technique will decrease the common dosimetric and set up errors prevalent in using physical treatment accessories like bolus. The groundwork for a novel treatment beam used to enhance surface dose to within 80-100% of the dose at dmax by utilizing low-Z (Carbon) targets of various percent CSDA range thickness operated at 2.5–4 MeV used in conjunction with a clinical 6 MV beam is presented herein. Methods: A standard Monte Carlo model of a Varian Clinac accelerator was developed to manufacturers specifications. Simulations were performed using Be, C, AL, and C, as potential low-Z targets, placed in the secondary target position. The results determined C to be the target material of choice. Simulations of 15, 30 and 60% CSDA range C beams were propagated through slab phantoms. The resulting PDDs were weighted and combined with a standard 6 MV treatment beam. Versions of the experimental targets were installed into a 2100C Clinac and the models were validated. Results: Carbon was shown to be the low-Z material of choice for this project. Using combinations of 15, 30, 60% CSDA beams operated at 2.5 and 4 MeV in combination with a standard 6 MV treatment beam the surface dose was shown to be enhanced to within 80–100% the dose at dmax. Conclusion: The modeled low-Z beams were successfully validated using machined versions of the targets. Water phantom measurements and slab phantom simulations show excellent correlation. Patient simulations are now underway to compare the use of bolus with the proposed novel beams. NSERC

  6. Irrigation in dose assessments models

    Energy Technology Data Exchange (ETDEWEB)

    Bergstroem, Ulla; Barkefors, Catarina [Studsvik RadWaste AB, Nykoeping (Sweden)

    2004-05-01

    SKB has carried out several safety analyses for repositories for radioactive waste, one of which was SR 97, a multi-site study concerned with a future deep bedrock repository for high-level waste. In case of future releases due to unforeseen failure of the protective multiple barrier system, radionuclides may be transported with groundwater and may reach the biosphere. Assessments of doses have to be carried out with a long-term perspective. Specific models are therefore employed to estimate consequences to man. It has been determined that the main pathway for nuclides from groundwater or surface water to soil is via irrigation. Irrigation may cause contamination of crops directly by e.g. interception or rain-splash, and indirectly via root-uptake from contaminated soil. The exposed people are in many safety assessments assumed to be self-sufficient, i.e. their food is produced locally where the concentration of radionuclides may be the highest. Irrigation therefore plays an important role when estimating consequences. The present study is therefore concerned with a more extensive analysis of the role of irrigation for possible future doses to people living in the area surrounding a repository. Current irrigation practices in Sweden are summarised, showing that vegetables and potatoes are the most common crops for irrigation. In general, however, irrigation is not so common in Sweden. The irrigation model used in the latest assessments is described. A sensitivity analysis is performed showing that, as expected, interception of irrigation water and retention on vegetation surfaces are important parameters. The parameters used to describe this are discussed. A summary is also given how irrigation is proposed to be handled in the international BIOMASS (BIOsphere Modelling and ASSessment) project and in models like TAME and BIOTRAC. Similarities and differences are pointed out. Some numerical results are presented showing that surface contamination in general gives the

  7. Irrigation in dose assessments models

    International Nuclear Information System (INIS)

    Bergstroem, Ulla; Barkefors, Catarina

    2004-05-01

    SKB has carried out several safety analyses for repositories for radioactive waste, one of which was SR 97, a multi-site study concerned with a future deep bedrock repository for high-level waste. In case of future releases due to unforeseen failure of the protective multiple barrier system, radionuclides may be transported with groundwater and may reach the biosphere. Assessments of doses have to be carried out with a long-term perspective. Specific models are therefore employed to estimate consequences to man. It has been determined that the main pathway for nuclides from groundwater or surface water to soil is via irrigation. Irrigation may cause contamination of crops directly by e.g. interception or rain-splash, and indirectly via root-uptake from contaminated soil. The exposed people are in many safety assessments assumed to be self-sufficient, i.e. their food is produced locally where the concentration of radionuclides may be the highest. Irrigation therefore plays an important role when estimating consequences. The present study is therefore concerned with a more extensive analysis of the role of irrigation for possible future doses to people living in the area surrounding a repository. Current irrigation practices in Sweden are summarised, showing that vegetables and potatoes are the most common crops for irrigation. In general, however, irrigation is not so common in Sweden. The irrigation model used in the latest assessments is described. A sensitivity analysis is performed showing that, as expected, interception of irrigation water and retention on vegetation surfaces are important parameters. The parameters used to describe this are discussed. A summary is also given how irrigation is proposed to be handled in the international BIOMASS (BIOsphere Modelling and ASSessment) project and in models like TAME and BIOTRAC. Similarities and differences are pointed out. Some numerical results are presented showing that surface contamination in general gives the

  8. Control instrument for dose ratemeters

    International Nuclear Information System (INIS)

    Rutzki, B.

    1974-01-01

    The testing apparatus for the dose ratemeter has safety locking mechanisms for protection of the operating personnel allowing the apparatus to be opened only if the nuclear radiation source is shielded. For this purpose, the apparatus consists of a casing with an opening to be locked. The lock may be in the shape of a hollow cylinder matching with the likewise cylindrical wall of the casing through a ball bearing. The hollow-cylindrical part has an internal flange with a recess in which a shielding body in the shape of a roller is supported. The shielding body has a flattening on the jacket surface and penetrations for the nuclear radiation filled with absorbing material. Because of the eccentric bearing of the rotating shielding body with respect to the flange resp. the recess, the door connot be opened. Only after removal of the shielding block from the recess whereby the movement is caused from outside the casing by means of a knurling wheel, can the door be opened. Now, however, the shielding block is in the way of the beam from the nuclear radiation source and is shielding the door completely from it. (DG) [de

  9. Comparison of Nordic dose models

    International Nuclear Information System (INIS)

    Thykier-Nielsen, S.

    1978-04-01

    A comparison is made between the models used in the four Nordic countries, Finland, Norway, Sweden and Denmark, for calculation of concentrations and doses from releases of radioactive material to the atmosphere. The comparison is limited to the near-zone models, i.e. the models for calculation of concentrations and doses within 50 km from the release point, and it comprises the following types of calculation: a. Concentrations of airborne material, b. External gamma doses from a plume, c. External gamma doses from radioactive material deposited on the ground. All models are based on the gaussian dispersion model (the gaussian plume model). Unit releases of specific isotopes under specific meteorological conditions are assumed. On the basis of the calculation results from the models, it is concluded that there are no essential differences. The difference between the calculation results only exceeds a factor of 3 in special cases. It thus lies within the known limits of uncertainty for the gaussian plume model. (author)

  10. The cost of occupational dose

    International Nuclear Information System (INIS)

    Fleishman, A.B.; Clark, M.J.

    1980-01-01

    The optimization of radiological protection will routinely involve the balancing of public and occupational exposure, particularly within the nuclear fuel cycle. For example the reduction of public exposure from an effluent stream could lead to increases in occupational exposure from treatment, storage and disposal operations. A methodology is propased for the estimation of the cost of occupational exposure in the UK (Pound man-Sv -1 ) based on valuations of changes in risk. A variable value for the cost of the occupational man-Sv is obtained depending on per caput dose levels. The values at particular per caput dose levels are different for occupational workers and the general public, because of different demography and assumptions on risk perception and aversion. They are however approximately the same when the per caput doses are expressed as percentages of the dose limits for workers and the general public respectively. An example of the application of the derived cost of the occupational man-Sv to an optimisation problem is given. (author)

  11. Dose response relationship and Alara

    International Nuclear Information System (INIS)

    Hubert, P.

    1986-09-01

    In this paper, it will be shown how dose-response relationships allow to give quantitative figures for the detriment of irradiation. At this stage, the detriment is expressed directly as a certain number of health effects, whose valuation is not dealt with here. The present tools for quantifying, their weaknesses and their strenghts, and their scientific basis will be developed

  12. Model of organ dose combination

    International Nuclear Information System (INIS)

    Valley, J.-F.; Lerch, P.

    1977-01-01

    The ICRP recommendations are based on the limitation of the dose to each organ. In the application and for a unique source the critical organ concept allows to limit the calculation and represents the irradiation status of an individuum. When several sources of radiation are involved the derivation of the dose contribution of each source to each organ is necessary. In order to represent the irradiation status a new parameter is to be defined. Propositions have been made by some authors, in particular by Jacobi introducing at this level biological parameters like the incidence rate of detriment and its severity. The new concept is certainly richer than a simple dose notion. However, in the actual situation of knowledge about radiation effects an intermediate parameter, using only physical concepts and the maximum permissible doses to the organs, seems more appropriate. The model, which is a generalization of the critical organ concept and shall be extended in the future to take the biological effects into account, will be presented [fr

  13. Dose reduction - the radiologist's view

    International Nuclear Information System (INIS)

    Russell, J.G.B.

    1984-01-01

    The magnitude of the exposure to ionising radiation dominates radiological practice in only three fields, i.e. foetal radiography, mammography and computed tomography. The balance between risk and benefit are briefly examined. The types of hazard considered are carcinogenesis, genetic injury and organogenesis. Ways of achieving a reduction of the dose to the patient are also briefly discussed. (U.K.)

  14. Compliance with public dose limits

    International Nuclear Information System (INIS)

    Mason, G.C.

    1991-01-01

    Radiation, in various forms, is ubiquitous in the environment. Natural background radiation leads to an average radiation exposure for the general population of about 2 mSv per year. The mining and milling of radioactive ores - uranium and mineral sands - may cause a small increase in radiation exposure for some members of the public. Because any such increment in exposure is small compared with a natural exposure that is variable and difficult to quantify accurately, it is not easy to determine what proportion of the total dose received by a member of the public can be attributed to mining and milling activities. Consequently, because public dose limits apply and to those doses caused by human activity, such as mining and milling, the task of demonstrating compliance can be hampered by uncertainty. Some strategies for handling this situation are discussed. While the discussion concentrates on public dose limits, much of it may also be applicable, or adaptable, to occupational exposure. 4 refs., 2 figs

  15. Dose modeling in ultraviolet phototherapy

    International Nuclear Information System (INIS)

    Grimes, David Robert; Robbins, Chris; O'Hare, Neil John

    2010-01-01

    Purpose: Ultraviolet phototherapy is widely used in the treatment of numerous skin conditions. This treatment is well established and largely beneficial to patients on both physical and psychological levels; however, overexposure to ultraviolet radiation (UVR) can have detrimental effects, such as erythemal responses and ocular damage in addition to the potentially carcinogenic nature of UVR. For these reasons, it is essential to control and quantify the radiation dose incident upon the patient to ensure that it is both biologically effective and has the minimal possible impact on the surrounding unaffected tissue. Methods: To date, there has been little work on dose modeling, and the output of artificial UVR sources is an area where research has been recommended. This work characterizes these sources by formalizing an approach from first principles and experimentally examining this model. Results: An implementation of a line source model is found to give impressive accuracy and quantifies the output radiation well. Conclusions: This method could potentially serve as a basis for a full computational dose model for quantifying patient dose.

  16. The dose-rate effect

    International Nuclear Information System (INIS)

    Steel, G.G.

    1989-01-01

    This paper presents calculations that illustrate two conclusions; for any particular cell type there will be a critical radius at which tumor control breaks down, and the radius at which this occurs is strongly dependent upon the low-dose-rate radiosensitivity of the cells

  17. Dose limits for ionising radiation

    International Nuclear Information System (INIS)

    Gifford, D.

    1989-01-01

    Dose limits for exposure to ionising radiation are assessed to see if they give sufficient protection both for the occupationally exposed and for the general public. It is concluded that current limits give a level of safety that satisfies the necessary criteria in the light of present knowledge and further reductions would be unlikely to improve standards of safety. (author)

  18. Effects of ground surface decontamination on the air radiation dose rate. Results of a decontamination trial at a playground lot in a Fukushima residential area

    International Nuclear Information System (INIS)

    Tagawa, Akihiro

    2012-01-01

    The Japan Atomic Energy Agency decontaminated schools, playgrounds, swimming pools, and houses in nonevacuated, less-contaminated areas in Fukushima for environmental restoration. A small, 150 m 2 playground lot in the residential area was chosen for decontamination demonstration, which used routinely available tools and commodities to carry out the work. The surfaces of playground lot equipment, such as swings, slides, and horizontal iron bars, were completely decontaminated by brushing with water and/or detergent. Side gutters around the playground lot were cleaned by removing the mud and then brushed and washed with a high-pressure water jet (7 MPa). The air dose rate at the playground lot was dominated by radiation from the ground surface and adjacent surroundings, such as apartments and rice fields. Two or three centimeters of the surface soil contaminated with cesium was removed manually with shovels, hoes, and other gardening tools. This significantly reduced the average air dose rate of the entire playground lot from 1.5 μSv/h before decontamination to 0.6 μSv/h. These results showed that ground surface decontamination can contribute measurably to the reduction in air dose rate in relatively small areas in residential areas. (author)

  19. Dose due to 40K

    International Nuclear Information System (INIS)

    Escareno J, E.; Vega C, H. R.

    2011-10-01

    The dose due to 40 K has been estimated. Potassium is one of the most abundant elements in nature, being approximately 2% of the Earth's crust. Potassium has three isotopes 39 K, 40 K and 41 K, two are stable while 40 K is radioactive with a half life of 1.2x10 9 years; there is 0.0117% 40 K-to-K ratio. Potassium plays an important role in plants, animals and humans growth and reproduction. Due to the fact that K is an essential element for humans, 40 K is the most abundant radioisotope in human body. In order to keep good health conditions K must be intake at daily basis trough food and beverages, however when K in ingested above the requirements produce adverse health effects in persons with renal, cardiac and hypertension problems or suffering diabetes. In 89.3% 40 K decays to 40 C through β-decay, in 10.3% decays through electronic capture and emitting 1.46 MeV γ-ray. K is abundant in soil, construction materials, sand thus γ-rays produced during 40 K decay contribute to external dose. For K in the body practically all 40 K decaying energy is absorbed by the body; thus 40 K contributes to total dose in humans and it is important to evaluate its contribution. In this work a set of 40 K sources were prepared using different amounts of KCl salt, a γ-ray spectrometer with a NaI(Tl) was characterized to standardized the sources in order to evaluate the dose due to 40 K. Using thermoluminescent dosemeters the dose due to 40 K was measured and related to the amount of 40 K γ-ray activity. (Author)

  20. Radiobiological modelling of dose-gradient effects in low dose rate, high dose rate and pulsed brachytherapy

    International Nuclear Information System (INIS)

    Armpilia, C; Dale, R G; Sandilos, P; Vlachos, L

    2006-01-01

    This paper presents a generalization of a previously published methodology which quantified the radiobiological consequences of dose-gradient effects in brachytherapy applications. The methodology uses the linear-quadratic (LQ) formulation to identify an equivalent biologically effective dose (BED eq ) which, if applied uniformly to a specified tissue volume, would produce the same net cell survival as that achieved by a given non-uniform brachytherapy application. Multiplying factors (MFs), which enable the equivalent BED for an enclosed volume to be estimated from the BED calculated at the dose reference surface, have been calculated and tabulated for both spherical and cylindrical geometries. The main types of brachytherapy (high dose rate (HDR), low dose rate (LDR) and pulsed (PB)) have been examined for a range of radiobiological parameters/dimensions. Equivalent BEDs are consistently higher than the BEDs calculated at the reference surface by an amount which depends on the treatment prescription (magnitude of the prescribed dose) at the reference point. MFs are closely related to the numerical BED values, irrespective of how the original BED was attained (e.g., via HDR, LDR or PB). Thus, an average MF can be used for a given prescribed BED as it will be largely independent of the assumed radiobiological parameters (radiosensitivity and α/β) and standardized look-up tables may be applicable to all types of brachytherapy treatment. This analysis opens the way to more systematic approaches for correlating physical and biological effects in several types of brachytherapy and for the improved quantitative assessment and ranking of clinical treatments which involve a brachytherapy component

  1. Collective dose, conceptual basis and practical applications

    International Nuclear Information System (INIS)

    Bonka, H.

    1985-01-01

    In the ICRP Publications no. 22(1973) and no. 26(1977), the ICRP recommends that the maximum permissible whole-body dose by kept below the dose limits corresponding to the sum of all effective dose equivalents of the persons concerned, i.e. the collective dose. The effective dose equivalent is recommended by the ICRP for use as a new quantity for evaluating the stochastic radiation dose for individual persons. Examples are given by the author explaining cost-benefit analyses according to ICRP recommendations, especially discussing the definition of optimum local dose limits with regard to shielding design in nuclear installations. (DG) [de

  2. Tank Z-361 dose rate calculations

    International Nuclear Information System (INIS)

    Richard, R.F.

    1998-01-01

    Neutron and gamma ray dose rates were calculated above and around the 6-inch riser of tank Z-361 located at the Plutonium Finishing Plant. Dose rates were also determined off of one side of the tank. The largest dose rate 0.029 mrem/h was a gamma ray dose and occurred 76.2 cm (30 in.) directly above the open riser. All other dose rates were negligible. The ANSI/ANS 1991 flux to dose conversion factor for neutrons and photons were used in this analysis. Dose rates are reported in units of mrem/h with the calculated uncertainty shown within the parentheses

  3. Response of pig skin to single doses of irradiation from strontium-90 sources of differing surface area

    Energy Technology Data Exchange (ETDEWEB)

    Hopewell, J.W.; Hamlet, R.; Peel, D. (Churchill Hospital, Oxford (UK). Research Inst.)

    1985-08-01

    In the present investigations the effects of irradiation of pig skin with 22.5 and 40 mm diameter /sup 90/Sr plaques are compared. In addition to comparing peak epithelial reactions, comparisons were also made as to the healing times for comparable peak skin reactions for each field size. The ED/sub 50/ values (dose to produce moist desquamation in 50% of the skin fields) 26.5 +- 1.5 Gy for the 22.5 diameter field was not significantly different from that obtained for the larger 40 mm diameter source (ED/sub 50/ 29.0 +- 1.5 Gy).

  4. The response of pig skin to single doses of irradiation from strontium-90 sources of differing surface area

    International Nuclear Information System (INIS)

    Hopewell, J.W.; Hamlet, R.; Peel, D.

    1985-01-01

    In the present investigations the effects of irradiation of pig skin with 22.5 and 40 mm diameter 90 Sr plaques are compared. In addition to comparing peak epithelial reactions, comparisons were also made as to the healing times for comparable peak skin reactions for each field size. The ED 50 values (dose to produce moist desquamation in 50% of the skin fields) 26.5+-1.5 Gy for the 22.5 diameter field was not significantly different from that obtained for the larger 40 mm diameter source (ED 50 29.0+-1.5 Gy). (U.K.)

  5. Dose levels in conventional X-rays

    International Nuclear Information System (INIS)

    Guerra M, J. A.; Gonzalez G, J. A.; Pinedo S, A.; Salas L, M. A.; Vega C, H. R.; Rivera M, T.; Azorin N, J.

    2009-10-01

    There were a series of measures in the General Hospital of Fresnillo in the X-ray Department in the areas of X-1 and X-2-ray rooms and in the neonatal intensive care unit 2, was determined the dose surface entry in eyes, thyroid and gonads for patients undergoing to X-ray study of chest Tele by thermoluminescent dosimetry. Five dosemeters were used in each one of the scans; so find the following dose ranges 20 + - 23 mGy to 350 + - 41 mGy. With the results obtained we can conclude that the procedures used and the equipment calibration is adequate. (Author)

  6. Mixed field dose equivalent measuring instruments

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; McDonald, J.C.; Endres, G.W.R.; Quam, W.

    1985-01-01

    In the past, separate instruments have been used to monitor dose equivalent from neutrons and gamma rays. It has been demonstrated that it is now possible to measure simultaneously neutron and gamma dose with a single instrument, the tissue equivalent proportional counter (TEPC). With appropriate algorithms dose equivalent can also be determined from the TEPC. A simple ''pocket rem meter'' for measuring neutron dose equivalent has already been developed. Improved algorithms for determining dose equivalent for mixed fields are presented. (author)

  7. Mathematical model for evaluation of dose-rate effect on biological responses to low dose γ-radiation

    International Nuclear Information System (INIS)

    Ogata, H.; Kawakami, Y.; Magae, J.

    2003-01-01

    Full text: To evaluate quantitative dose-response relationship on the biological response to radiation, it is necessary to consider a model including cumulative dose, dose-rate and irradiation time. In this study, we measured micronucleus formation and [ 3 H] thymidine uptake in human cells as indices of biological response to gamma radiation, and analyzed mathematically and statistically the data for quantitative evaluation of radiation risk at low dose/low dose-rate. Effective dose (ED x ) was mathematically estimated by fitting a general function of logistic model to the dose-response relationship. Assuming that biological response depends on not only cumulative dose but also dose-rate and irradiation time, a multiple logistic function was applied to express the relationship of the three variables. Moreover, to estimate the effect of radiation at very low dose, we proposed a modified exponential model. From the results of fitting curves to the inhibition of [ 3 H] thymidine uptake and micronucleus formation, it was obvious that ED 50 in proportion of inhibition of [ 3 H] thymidine uptake increased with longer irradiation time. As for the micronuclei, ED 30 also increased with longer irradiation times. These results suggest that the biological response depends on not only total dose but also irradiation time. The estimated response surface using the three variables showed that the biological response declined sharply when the dose-rate was less than 0.01 Gy/h. These results suggest that the response does not depend on total cumulative dose at very low dose-rates. Further, to investigate the effect of dose-rate within a wider range, we analyzed the relationship between ED x and dose-rate. Fitted curves indicated that ED x increased sharply when dose-rate was less than 10 -2 Gy/h. The increase of ED x signifies the decline of the response or the risk and suggests that the risk approaches to 0 at infinitely low dose-rate

  8. Infinite slab-shield dose calculations

    International Nuclear Information System (INIS)

    Russell, G.J.

    1989-01-01

    I calculated neutron and gamma-ray equivalent doses leaking through a variety of infinite (laminate) slab-shields. In the shield computations, I used, as the incident neutron spectrum, the leakage spectrum (<20 MeV) calculated for the LANSCE tungsten production target at 90 degree to the target axis. The shield thickness was fixed at 60 cm. The results of the shield calculations show a minimum in the total leakage equivalent dose if the shield is 40-45 cm of iron followed by 20-15 cm of borated (5% B) polyethylene. High-performance shields can be attained by using multiple laminations. The calculated dose at the shield surface is very dependent on shield material. 4 refs., 4 figs., 1 tab

  9. Organ or tissue doses, effective dose and collective effective dose from X-ray diagnosis, in Japan

    International Nuclear Information System (INIS)

    Murayama, Takashi; Nishizawa, Kanae; Noda, Yutaka; Kumamoto, Yoshikazu; Iwai, Kazuo.

    1996-01-01

    Effective doses and collective effective doses from X-ray diagnostic examinations were calculated on the basis of the frequency of examinations estimated by a nationwide survey and the organ or tissue doses experimentally determined. The average organ or tissue doses were determined with thermoluminescence dosimeters put at various sites of organs or tissues in an adult and a child phantom. Effective doses (effective dose equivalents) were calculated as the sum of the weighted equivalent doses in all the organs or tissues of the body. As the examples of results, the effective doses per radiographic examination were approximately 7 mGy for male, and 9 mGy for female angiocardiography, and about 3 mGy for barium meal. Annual collective effective dose from X-ray diagnostic examinations in 1986 were about 104 x 10 3 person Sv from radiography and 118 x 10 3 person Sv from fluoroscopy, with the total of 222 x 10 3 person Sv. (author)

  10. Update on pediatric resuscitation drugs: high dose, low dose, or no dose at all.

    Science.gov (United States)

    Sorrentino, Annalise

    2005-04-01

    Pediatric resuscitation has been a topic of discussion for years. It is difficult to keep abreast of changing recommendations, especially for busy pediatricians who do not regularly use these skills. This review will focus on the most recent guidelines for resuscitation drugs. Three specific questions will be discussed: standard dose versus high-dose epinephrine, amiodarone use, and the future of vasopressin in pediatric resuscitation. The issue of using high-dose epinephrine for cardiopulmonary resuscitation refractory to standard dose epinephrine has been a topic of debate for many years. Recently, a prospective, double-blinded study was performed to help settle the debate. These results will be reviewed and compared with previous studies. Amiodarone is a medication that was added to the pediatric resuscitation algorithms with the most recent recommendations from the American Heart Association in 2000. Its use and safety will also be discussed. Another topic that is resurfacing in resuscitation is the use of vasopressin. Its mechanism and comparisons to other agents will be highlighted, although its use in the pediatric patient has not been thoroughly studied. Pediatric resuscitation is a constantly evolving subject that is on the mind of anyone taking care of sick children. Clinicians are continually searching for the most effective methods to resuscitate children in terms of short- and long-term outcomes. It is important to be familiar with not only the agents being used but also the optimal way to use them.

  11. Estimation of thyroid equivalent doses during evacuation based on body surface contamination levels in the nuclear accident of FDNPS in 2011

    Science.gov (United States)

    Ohba, Takashi; Hasegawa, Arifumi; Kohayakawa, Yoshitaka; Kondo, Hisayoshi; Suzuki, Gen

    2017-09-01

    To reduce uncertainty in thyroid dose estimation, residents' radiation protection behavior should be reflected in the estimation. Screening data of body surface contamination provide information on exposure levels during evacuation. Our purpose is to estimate thyroid equivalent doses based on body surface contamination levels using a new methodology. We obtained a record of 7,539 residents/evacuees. Geiger-Mueller survey meter measurement value in cpm was translated into Bq/cm2 according to the nuclides densities obtained by measuring clothing from two persons by germanium γ-spectrometer. The measurement value of body surface contamination on head was adjusted by a natural removal rate of 15 hours and radionuclides' physical half-life. Thyroid equivalent dose of 1-year-old children by inhalation was estimated by two-dimensional Monte Carlo simulation. The proportions of evacuees/residents with measurement value in cpm of Namie and Minamisoma groups were higher than those of other groups during both periods (p<0.01, Kruskal-Wallis). During 12-14 March period, 50 and 95 percentiles of thyroid equivalent doses by inhalation were estimated as 2.7 and 86.0 mSv, respectively, for Namie group, and 4.2 and 17.2 mSv, respectively, for Minamisoma group, 0.1 and 1.0 mSv, respectively, for Tomioka/Okuma/Futaba/Naraha group, and 0.2 and 2.1 mSv, respectively, for the other group. During 15- 17 March period, 50 and 95 percentiles of thyroid equivalent doses by inhalation were 0.8 and 15.7 mSv, respectively, for Namie group, and 1.6 and 8.4 mSv, respectively, for Minamisoma group, 0.2 and 13.2 mSv, respectively, for Tomioka/Okuma/Futaba/Naraha group, and 1.2 and 12.7 mSv, respectively, for the other group. It was indicated that inhalation dose was generally higher in Namie and Minamisoma groups during 12-14 March than those during 15-17 March might reflect different self-protective behavior to radioactive plumes from other groups.

  12. Dose apportionment for BARC facilities

    International Nuclear Information System (INIS)

    Preetha, J.; Sundar, D.; Munshi, S.K.; Pradeepkumar, K.S.

    2017-01-01

    One of the important responsibilities of BARC Safety Council (BSC) is to ensure that appropriate measures are in place to protect the members of the public and the environment from the undue effects of radioactive releases from the facilities regulated by BSC. It is with this aim in mind that a Standing Committee for Dose Apportionment (DAC) was constituted by BSC in 2005, to ensure that the limits are set by the regulatory body for release of low-level gaseous and liquid effluents into the environment from BARC facilities. There are three Committees for dose apportionment constituted by the Chairman, BSC, viz, DAC-TK for Tarapur and Kalpakkam facilities, DAC-TV for Trombay and DACSF for specific faculties

  13. Dose assessment in radiological accidents

    International Nuclear Information System (INIS)

    Donkor, S.

    2013-04-01

    The applications of ionizing radiation bring many benefits to humankind, ranging from power generation to uses in medicine, industry and agriculture. Facilities that use radiation source require special care in the design and operation of equipment to prevent radiation injury to workers or to the public. Despite considerable development of radiation safety, radiation accidents do happen. The purpose of this study is therefore to discuss how to assess doses to people who will be exposed to a range of internal and external radiation sources in the event of radiological accidents. This will go a long way to complement their medical assessment thereby helping to plan their treatment. Three radiological accidents were reviewed to learn about the causes of those accidents and the recommendations that were put in place to prevent recurrence of such accidents. Various types of dose assessment methods were discussed.(au)

  14. Atmospheric radiation flight dose rates

    Science.gov (United States)

    Tobiska, W. K.

    2015-12-01

    Space weather's effects upon the near-Earth environment are due to dynamic changes in the energy transfer processes from the Sun's photons, particles, and fields. Of the domains that are affected by space weather, the coupling between the solar and galactic high-energy particles, the magnetosphere, and atmospheric regions can significantly affect humans and our technology as a result of radiation exposure. Space Environment Technologies (SET) has been conducting space weather observations of the atmospheric radiation environment at aviation altitudes that will eventually be transitioned into air traffic management operations. The Automated Radiation Measurements for Aerospace Safety (ARMAS) system and Upper-atmospheric Space and Earth Weather eXperiment (USEWX) both are providing dose rate measurements. Both activities are under the ARMAS goal of providing the "weather" of the radiation environment to improve aircraft crew and passenger safety. Over 5-dozen ARMAS and USEWX flights have successfully demonstrated the operation of a micro dosimeter on commercial aviation altitude aircraft that captures the real-time radiation environment resulting from Galactic Cosmic Rays and Solar Energetic Particles. The real-time radiation exposure is computed as an effective dose rate (body-averaged over the radiative-sensitive organs and tissues in units of microsieverts per hour); total ionizing dose is captured on the aircraft, downlinked in real-time, processed on the ground into effective dose rates, compared with NASA's Langley Research Center (LaRC) most recent Nowcast of Atmospheric Ionizing Radiation System (NAIRAS) global radiation climatology model runs, and then made available to end users via the web and smart phone apps. Flight altitudes now exceed 60,000 ft. and extend above commercial aviation altitudes into the stratosphere. In this presentation we describe recent ARMAS and USEWX results.

  15. Dose to patient in tomosynthesis

    International Nuclear Information System (INIS)

    Minambres Moro, A.; Fernandez Leton, P.; Garcia Rui-Zorrilla, J.; Perez Moreno, J. M.; Zucca Aparicio, D.

    2013-01-01

    They are beginning to implement digital mammography with the possibility of acquiring in tomosynthesis, whose biggest advantage is to distinguish structures without overlapping through of pseudotridimensionals images. With these modified mammograms can acquire a planar mammography, with fixed x-ray tube, or a tomosynthesis with tube by turning. For acquire tomosynthesis is necessary a detector of high efficiency together with tungsten white tubes. The objective of this study is to know the dose received by the patient with this new imaging. (Author)

  16. Radiation dose from cigarette tobacco

    International Nuclear Information System (INIS)

    Papastefanou, Constantin

    2008-01-01

    The radioactivity in tobacco leaves collected from 15 different regions of Greece before cigarette production was studied in order to estimate the effective dose from cigarette tobacco due to the naturally occurring primordial radionuclides, such as 226 Ra and 210 Pb of the uranium series and 228 Ra of the thorium series and or man-made produced radionuclides, such as 137 Cs of Chernobyl origin. Gamma-ray spectrometry was applied using Ge planar and coaxial type detectors of high resolution and high efficiency. It was concluded that the annual effective dose due to inhalation for adults (smokers) for 226 Ra varied from 42.5 to 178.6 μSv y -1 (average 79.7 μSv y -1 ), while for 228 Ra from 19.3 to 116.0 μSv y -1 (average 67.1 μSv y -1 ) and for 210 Pb from 47.0 to 134.9 μSv y -1 (average 104.7 μSv y -1 ), that is the same order of magnitude for each radionuclide. The sum of the effective dose of the three natural radionuclides varied from 151.9 to 401.3 μSv y -1 (average 251.5 μSv y -1 ). The annual effective dose from 137 Cs of Chernobyl origin was three orders of magnitude lower as it varied from 70.4 to 410.4 μSv y -1 (average 199.3 μSv y -1 ). (author)

  17. Prenatal radiation exposure. Dose calculation

    International Nuclear Information System (INIS)

    Scharwaechter, C.; Schwartz, C.A.; Haage, P.; Roeser, A.

    2015-01-01

    The unborn child requires special protection. In this context, the indication for an X-ray examination is to be checked critically. If thereupon radiation of the lower abdomen including the uterus cannot be avoided, the examination should be postponed until the end of pregnancy or alternative examination techniques should be considered. Under certain circumstances, either accidental or in unavoidable cases after a thorough risk assessment, radiation exposure of the unborn may take place. In some of these cases an expert radiation hygiene consultation may be required. This consultation should comprise the expected risks for the unborn while not perturbing the mother or the involved medical staff. For the risk assessment in case of an in-utero X-ray exposition deterministic damages with a defined threshold dose are distinguished from stochastic damages without a definable threshold dose. The occurrence of deterministic damages depends on the dose and the developmental stage of the unborn at the time of radiation. To calculate the risks of an in-utero radiation exposure a three-stage concept is commonly applied. Depending on the amount of radiation, the radiation dose is either estimated, roughly calculated using standard tables or, in critical cases, accurately calculated based on the individual event. The complexity of the calculation thereby increases from stage to stage. An estimation based on stage one is easily feasible whereas calculations based on stages two and especially three are more complex and often necessitate execution by specialists. This article demonstrates in detail the risks for the unborn child pertaining to its developmental phase and explains the three-stage concept as an evaluation scheme. It should be noted, that all risk estimations are subject to considerable uncertainties.

  18. Dose assessment models. Annex A

    International Nuclear Information System (INIS)

    1982-01-01

    The models presented in this chapter have been separated into 2 general categories: environmental transport models which describe the movement of radioactive materials through all sectors of the environment after their release, and dosimetric models to calculate the absorbed dose following an intake of radioactive materials or exposure to external irradiation. Various sections of this chapter also deal with atmospheric transport models, terrestrial models, and aquatic models.

  19. Tolerance doses for treatment planning

    International Nuclear Information System (INIS)

    Lyman, J.T.

    1985-10-01

    Data for the tolerance of normal tissues or organs to (low-LET) radiation has been compiled from a number of sources which are referenced at the end of this document. This tolerance dose data are ostensibly for uniform irradiation of all or part of an organ, and are for either 5% (TD 5 ) or 50% (TD 50 ) complication probability. The ''size'' of the irradiated organ is variously stated in terms of the absolute volume or the fraction of the organ volume irradiated, or the area or the length of the treatment field. The accuracy of these data is questionable. Much of the data represents doses that one or several experienced therapists have estimated could be safely given rather than quantitative analyses of clinical observations. Because these data have been obtained from multiple sources with possible different criteria for the definition of a complication, there are sometimes different values for what is apparently the same endpoint. The data from some sources shows a tendancy to be quantized in 5 Gy increments. This reflects the size of possible round off errors. It is believed that all these data have been accumulated without the benefit of 3-D dose distributions and therefore the estimates of the size of the volume and/or the uniformity of the irradiation may be less accurate than is now possible. 19 refs., 4 figs

  20. Gamma dose rate effect on JFET transistors

    International Nuclear Information System (INIS)

    Assaf, J.

    2011-04-01

    The effect of Gamma dose rate on JFET transistors is presented. The irradiation was accomplished at the following available dose rates: 1, 2.38, 5, 10 , 17 and 19 kGy/h at a constant dose of 600 kGy. A non proportional relationship between the noise and dose rate in the medium range (between 2.38 and 5 kGy/h) was observed. While in the low and high ranges, the noise was proportional to the dose rate as the case of the dose effect. This may be explained as follows: the obtained result is considered as the yield of a competition between many reactions and events which are dependent on the dose rate. At a given values of that events parameters, a proportional or a non proportional dose rate effects are generated. No dependence effects between the dose rate and thermal annealing recovery after irradiation was observed . (author)

  1. Calculation methods for determining dose equivalent

    International Nuclear Information System (INIS)

    Endres, G.W.R.; Tanner, J.E.; Scherpelz, R.I.; Hadlock, D.E.

    1987-11-01

    A series of calculations of neutron fluence as a function of energy in an anthropomorphic phantom was performed to develop a system for determining effective dose equivalent for external radiation sources. Critical organ dose equivalents are calculated and effective dose equivalents are determined using ICRP-26 [1] methods. Quality factors based on both present definitions and ICRP-40 definitions are used in the analysis. The results of these calculations are presented and discussed. The effective dose equivalent determined using ICRP-26 methods is significantly smaller than the dose equivalent determined by traditional methods. No existing personnel dosimeter or health physics instrument can determine effective dose equivalent. At the present time, the conversion of dosimeter response to dose equivalent is based on calculations for maximal or ''cap'' values using homogeneous spherical or cylindrical phantoms. The evaluated dose equivalent is, therefore, a poor approximation of the effective dose equivalent as defined by ICRP Publication 26. 3 refs., 2 figs., 1 tab

  2. External dose conversion factor from canal water

    International Nuclear Information System (INIS)

    Bhargava, Pradeep; Chitra, S.; Mhatre, Arti S.; Singh, Kapil Deo

    2016-01-01

    External dose needs to be estimated for the radioactivity discharged into the canal, as it constitutes one of the pathways of exposure to the public. Two activities are considered here: i) a walk along the bank of the canal ii) and the walk on the bridge. A concentration of 1 Bq/l is assumed here for the gross beta activity for the estimation of the dose conversion factor. A canal of width 14.39 m and the depth of 2.5 m is considered for this study. Length of the canal is taken to be infinite. Canal side wall is assumed to be the 25 cm thick concrete. Two points are selected, one on the bank, and the second on a bridge 1 m above the top surface of canal water. Dose Conversion factors for the person moving on the Bridge (at one meter above the water surface) and standing on bank of canal is estimated by using the QAD CG code for 137 Cs. Dose conversion factors for the location mentioned above are found to be 1.11E-10 Sv/hr/(Bq/l) and 1.55 E-11 Sv/hr/(Bq/l) for bridge and bank of canal respectively. (author)

  3. A probabilistic approach to quantify the uncertainties in internal dose assessment using response surface and neural network

    International Nuclear Information System (INIS)

    Baek, M.; Lee, S.K.; Lee, U.C.; Kang, C.S.

    1996-01-01

    A probabilistic approach is formulated to assess the internal radiation exposure following the intake of radioisotopes. This probabilistic approach consists of 4 steps as follows: (1) screening, (2) quantification of uncertainties, (3) propagation of uncertainties, and (4) analysis of output. The approach has been applied for Pu-induced internal dose assessment and a multi-compartment dosimetric model is used for internal transport. In this approach, surrogate models of original system are constructed using response and neural network. And the results of these surrogate models are compared with those of original model. Each surrogate model well approximates the original model. The uncertainty and sensitivity analysis of the model parameters are evaluated in this process. Dominant contributors to each organ are identified and the results show that this approach could serve a good tool of assessing the internal radiation exposure

  4. Field measurement and interpretation of beta doses and dose rates

    International Nuclear Information System (INIS)

    Selby, J.M.; Swinth, K.L.; Hooker, C.D.; Kenoyer, J.L.

    1983-01-01

    A wide variety of portable survey instruments employing GM, ionization chamber and scintillation detectors exist for the measurement of gamma exposure rates. Often these same survey instruments are used for monitoring beta fields. This is done by making measurements with and without a removable shield which is intended to shield out the non-penetrating component (beta) of the radiation field. The difference does not correspond to an absorbed dose rate for the beta field due to a variety of factors. Among these factors are the dependence on beta energy, source-detector geometries, mixed fields and variable ambient conditions. Attempting to use such measurements directly can lead to errors as high as a factor of 100. In many instances correction factors have been derived, that if properly applied, can reduce these errors substantially. However, this requires some knowledge of the beta spectra, calibration techniques and source geometry. This paper discusses some aspects of the proper use of instruments for beta measurements including the application of appropriate correction factors. Ionization type instruments are commonly used to measure beta dose rates. Through design and calibration these instruments will give an accurate reading only for uniform irradiation of the detection volume. Often in the field it is not feasible to meet these conditions. Large area uniform distributions of activity are not generally encountered and it is not possible to use large source-to-detector distances due to beta particle absorption in air. An example of correction factors required for various point sources is presented when a cutie pie ionization chamber is employed. The instrument reading is multiplied by the appropriate correction factor to obtain the dose rate at the window. When a different detector is used or for other geometries, a different set of correction factors must be used

  5. Radiation dose and cancer risk to children undergoing skull radiography

    International Nuclear Information System (INIS)

    Mazonakis, Michael; Damilakis, John; Raissaki, Maria; Gourtsoyiannis, Nicholas

    2004-01-01

    Background: Limited data exist in the literature concerning the patient-effective dose from paediatric skull radiography. No information has been provided regarding organ doses, patient dose during PA skull projection, risk of cancer induction and dose to comforters, i.e. individuals supporting children during exposure. Objective: To estimate patient-effective dose, organ doses, lifetime cancer mortality risk to children and radiation dose to comforters associated with skull radiography. Materials and methods: Data were collected from 136 paediatric examinations, including AP, PA and lateral skull radiographs. Entrance-surface dose (ESD) and dose to comforters were measured using thermoluminescent dosimeters. Patients were divided into the following age groups: 0.5-2, 3-7, 8-12 and 13-18 years. The patient-effective dose and corresponding organ doses were calculated using data from the NRPB and Monte Carlo techniques. The risk for fatal cancer induction was assessed using appropriate risk coefficients. Results: For AP, PA and lateral skull radiography, effective dose ranges were 8.8-25.4, 8.2-27.3 and 8.4-22.7 μSv respectively, depending upon the age of the child. For each skull projection, the organs receiving doses above 10 μGy are presented. The number of fatal cancers was found to be less than or equal to 2 per 1 million children undergoing a skull radiograph. The mean radiation dose absorbed by the hands of comforters was 13.4 μGy. Conclusions: The current study provides detailed tabular and graphical data on ESD, effective dose, organ doses and lifetime cancer mortality risk to children associated with AP, PA and lateral skull projections at all patient ages. (orig.)

  6. Editorial: New operational dose equivalent quantities

    International Nuclear Information System (INIS)

    Harvey, J.R.

    1985-01-01

    The ICRU Report 39 entitled ''Determination of Dose Equivalents Resulting from External Radiation Sources'' is briefly discussed. Four new operational dose equivalent quantities have been recommended in ICRU 39. The 'ambient dose equivalent' and the 'directional dose equivalent' are applicable to environmental monitoring and the 'individual dose equivalent, penetrating' and the 'individual dose equivalent, superficial' are applicable to individual monitoring. The quantities should meet the needs of day-to-day operational practice, while being acceptable to those concerned with metrological precision, and at the same time be used to give effective control consistent with current perceptions of the risks associated with exposure to ionizing radiations. (U.K.)

  7. The MIRD method of estimating absorbed dose

    International Nuclear Information System (INIS)

    Weber, D.A.

    1991-01-01

    The estimate of absorbed radiation dose from internal emitters provides the information required to assess the radiation risk associated with the administration of radiopharmaceuticals for medical applications. The MIRD (Medical Internal Radiation Dose) system of dose calculation provides a systematic approach to combining the biologic distribution data and clearance data of radiopharmaceuticals and the physical properties of radionuclides to obtain dose estimates. This tutorial presents a review of the MIRD schema, the derivation of the equations used to calculate absorbed dose, and shows how the MIRD schema can be applied to estimate dose from radiopharmaceuticals used in nuclear medicine

  8. Collective dose commitments from nuclear power programmes

    International Nuclear Information System (INIS)

    Beninson, D.

    1977-01-01

    The concepts of collective dose and collective dose commitment are discussed, particularly regarding their use to compare the relative importance of the exposure from several radiation sources and to predict future annual doses from a continuing practice. The collective dose commitment contributions from occupational exposure and population exposure due to the different components of the nuclear power fuel cycle are evaluated. A special discussion is devoted to exposures delivered over a very long time by released radionuclides of long half-lives and to the use of the incomplete collective dose commitment. The maximum future annual ''per caput'' doses from present and projected nuclear power programmes are estimated

  9. Radiation doses from residual radioactivity

    International Nuclear Information System (INIS)

    Okajima, Shunzo; Fujita, Shoichiro; Harley, John H.

    1987-01-01

    requires knowing the location of the person to within about 200 m from the time of the explosion to a few weeks afterwards. This is an effort that might be comparable to the present shielding study for survivors. The sizes of the four exposed groups are relatively small; however, the number has been estimated only for those exposed to fallout in the Nishiyama district of Nagasaki. Okajima listed the population of Nishiyama as about 600 at the time of the bomb. No figures are available for the other three groups. The individual exposures from residual radiation may not be significant compared with the direct radiation at the time of the bomb. On the other hand, individuals with potential exposure from these sources are dubious candidates for inclusion in a cohort that was presumably not exposed. For comparison with organ doses estimated in other parts of this program, the exposure estimates are converted to absorbed dose in tissue. The first conversion of exposure to absorbed dose in air uses the factor rad in air 0.87 x exposure in R. UNSCEAR uses an average combined factor of 0.7 to convert absorbed dose in air to absorbed dose in tissue for the whole body. This factor accounts for the change in material (air to tissue) and for backscatter and the shielding afforded by other tissues of the body. No allowance for shielding by buildings has been included here. The cumulative fallout exposures given above become absorbed doses in tissue of 12 to 24 rad for Nagasaki and 0.6 to 2 rad for Hiroshima. The cumulative exposures from induced radioactivity become absorbed doses in tissue of 18 to 24 rad for Nagasaki and about 50 rad for Hiroshima. (author)

  10. Expression of Cellular Isoform of Prion Protein on the Surface of Peripheral Blood Lymphocytes Among Women Exposed to Low Doses of Ionizing Radiation

    International Nuclear Information System (INIS)

    Klucinski, P.; Martirosian, G.; Mazur, B.; Kaufman, J.; Hrycek, A.; Masluch, E.; Cieslik, P.

    2007-01-01

    Ionizing radiation affect the expression of adhesive and co-stimulation molecules in lymphocytes. The objective of this study was to determinate the effect of low doses of ionizing radiation on the expression of prion protein PrPc on the surface peripheral blood lymphocytes in the women operating X-ray equipment. In female workers and persons of the control group the PrPc expression on CD3 (T-lymphocytes), Cd4 (T-helper), CD8 (T-cytotoxic) and CD19 (B- lymphocytes), were tested. We conclude that in women operating X-ray equipment the relationship between low doses of ionizing radiation and expression of PrPc on lymphocytes does exist concerning CD3, CD4 and CD lymphocytes. (author)

  11. The six year report: Acidification of surface water in Europe and North America. Dose/response relationships and long-term trends

    Energy Technology Data Exchange (ETDEWEB)

    Skjelkvaale, B L; Newell, A D; Raddum, G; Johannessen, M; Hovind, H; Tjomsland, T; Wathne, B M

    1994-12-31

    This report discusses The International Cooperative Programme on Assessment and Monitoring of Acidification of Rivers and Lakes, which is designed to (1) establish degree and extent of acidification of surface waters, (2) evaluate dose/response relationships and (3) define long-term trends and variations in aquatic chemistry and biota attributable to atmospheric pollution. Data from 200 sites in 14 countries of Europe and North America are available. Dose/response relationships show that the fauna is adapted to different water qualities in different regions, and that critical limits for the fauna must be calculated according to data for the specific region. Long-term trends of water chemistry show decreases in SO{sub 4}{sup 2-} and Ca{sup 2+} at many sites. Nitrate shows no consistent trends. 66 refs., 26 figs., 16 tabs.

  12. Estimation of effective dose during hysterosalpingography procedures

    International Nuclear Information System (INIS)

    Alzimamil, K.; Babikir, E.; Alkhorayef, M.; Sulieman, A.; Alsafi, K.; Omer, H.

    2014-08-01

    Hysterosalpingography (HSG) is the most frequently used diagnostic tool to evaluate the endometrial cavity and fallopian tube by using conventional x-ray or fluoroscopy. Determination of the patient radiation doses values from x-ray examinations provides useful guidance on where best to concentrate efforts on patient dose reduction in order to optimize the protection of the patients. The aims of this study were to measure the patients entrance surface air kerma doses (ESA K), effective doses and to compare practices between different hospitals in Sudan. ESA K were measured for patient using calibrated thermo luminance dosimeters (TLDs, Gr-200A). Effective doses were estimated using National Radiological Protection Board (NRPB) software. This study was conducted in five radiological departments: Two Teaching Hospitals (A and D), two private hospitals (B and C) and one University Hospital (E). The mean ESD was 20.1 mGy, 28.9 mGy, 13.6 mGy, 58.65 mGy, 35.7, 22.4 and 19.6 mGy for hospitals A,B,C,D, and E), respectively. The mean effective dose was 2.4 mSv, 3.5 mSv, 1.6 mSv, 7.1 mSv and 4.3 mSv in the same order. The study showed wide variations in the ESDs with three of the hospitals having values above the internationally reported values. Number of x-ray images, fluoroscopy time, operator skills x-ray machine type and clinical complexity of the procedures were shown to be major contributors to the variations reported. Results demonstrated the need for standardization of technique throughout the hospital. The results also suggest that there is a need to optimize the procedures. Local DRLs were proposed for the entire procedures. (author)

  13. Analysis of Cumulative Dose to Implanted Pacemaker According to Various IMRT Delivery Methods: Optimal Dose Delivery Versus Dose Reduction Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Woo; Hong, Se Mie [Dept. of Radiation Oncology, Konkuk University Medical Center, Seoul (Korea, Republic of)

    2011-11-15

    Cancer patients with implanted cardiac pacemaker occasionally require radiotherapy. Pacemaker may be damaged or malfunction during radiotherapy due to ionizing radiation or electromagnetic interference. Although radiotherapy should be planned to keep the dose to pacemaker as low as possible not to malfunction ideally, current radiation treatment planning (RTP) system does not accurately calculate deposited dose to adjacent field border or area beyond irradiated fields. In terms of beam delivery techniques using multiple intensity modulated fields, dosimetric effect of scattered radiation in high energy photon beams is required to be detailed analyzed based on measurement data. The aim of this study is to evaluate dose discrepancies of pacemaker in a RTP system as compared to measured doses. We also designed dose reduction strategy limited value of 2 Gy for radiation treatment patients with cardiac implanted pacemaker. Total accumulated dose of 145 cGy based on in-vivo dosimetry was satisfied with the recommendation criteria to prevent malfunction of pacemaker in SS technique. However, the 2 mm lead shielder enabled the scattered doses to reduce up to 60% and 40% in the patient and the phantom, respectively. The SS technique with the lead shielding could reduce the accumulated scattered doses less than 100 cGy. Calculated and measured doses were not greatly affected by the beam delivery techniques. In-vivo and measured doses on pacemaker position showed critical dose discrepancies reaching up to 4 times as compared to planned doses in RTP. The current SS technique could deliver lower scattered doses than recommendation criteria, but use of 2 mm lead shielder contributed to reduce scattered doses by 60%. The tertiary lead shielder can be useful to prevent malfunction or electrical damage of implanted pacemakers during radiotherapy. It is required to estimate more accurate scattered doses of the patient or medical device in RTP to design proper dose reduction strategy.

  14. Analysis of Cumulative Dose to Implanted Pacemaker According to Various IMRT Delivery Methods: Optimal Dose Delivery Versus Dose Reduction Strategy

    International Nuclear Information System (INIS)

    Lee, Jeong Woo; Hong, Se Mie

    2011-01-01

    Cancer patients with implanted cardiac pacemaker occasionally require radiotherapy. Pacemaker may be damaged or malfunction during radiotherapy due to ionizing radiation or electromagnetic interference. Although radiotherapy should be planned to keep the dose to pacemaker as low as possible not to malfunction ideally, current radiation treatment planning (RTP) system does not accurately calculate deposited dose to adjacent field border or area beyond irradiated fields. In terms of beam delivery techniques using multiple intensity modulated fields, dosimetric effect of scattered radiation in high energy photon beams is required to be detailed analyzed based on measurement data. The aim of this study is to evaluate dose discrepancies of pacemaker in a RTP system as compared to measured doses. We also designed dose reduction strategy limited value of 2 Gy for radiation treatment patients with cardiac implanted pacemaker. Total accumulated dose of 145 cGy based on in-vivo dosimetry was satisfied with the recommendation criteria to prevent malfunction of pacemaker in SS technique. However, the 2 mm lead shielder enabled the scattered doses to reduce up to 60% and 40% in the patient and the phantom, respectively. The SS technique with the lead shielding could reduce the accumulated scattered doses less than 100 cGy. Calculated and measured doses were not greatly affected by the beam delivery techniques. In-vivo and measured doses on pacemaker position showed critical dose discrepancies reaching up to 4 times as compared to planned doses in RTP. The current SS technique could deliver lower scattered doses than recommendation criteria, but use of 2 mm lead shielder contributed to reduce scattered doses by 60%. The tertiary lead shielder can be useful to prevent malfunction or electrical damage of implanted pacemakers during radiotherapy. It is required to estimate more accurate scattered doses of the patient or medical device in RTP to design proper dose reduction strategy.

  15. Dose indices: everybody wants a number

    International Nuclear Information System (INIS)

    Strauss, Keith J.

    2014-01-01

    This paper discusses the merits and weaknesses of the standard terms that have been developed to quantify CT dose: CT dose indices (CTDI), dose length product (DLP) and effective dose. The difference between the measured CTDI vol and the CTDI vol displayed on the CT scanner illustrates a clinical dilemma. Displayed CTDI vol represents the radiation dose delivered to a plastic phantom, which is significantly different from the dose delivered to the patient, depending on the size of the patient. Although effective dose is simple to calculate for an individual patient, it was never intended for this purpose. The need for a simple, appropriate method to estimate pediatric patient doses led to the development of the size-specific dose estimate (SSDE), the newest CT dose index. Here I compare SSDE and its merits to the use of effective dose to estimate patient dose. The discussion concludes with a few sample calculations and basic clinical applications of SSDE to better quantify pediatric patient dose from CT scans. (orig.)

  16. Dose-mapping distribution around MNSR

    CERN Document Server

    Jamal, M H

    2002-01-01

    The aim of this study is to establish the dose-rate map through the determination of radiological dose-rate levels in reactor hall, adjacent rooms, and outside the MNSR facility. Controlling dose rate to reactor operating personnel , dose map was established. The map covers time and distances in the reactor hall, during reactor operation at nominal power. Different measurement of dose rates in other areas of the reactor buildings was established. The maximum dose rate, during normal operation of the MNSR was 40 and 21 Sv/hr on the top of the reactor and near the pool fence, respectively. Whereas, gamma and neutron doses have not exceeded natural background in all rooms adjacent to the reactor hall or nearly buildings. The relation between the dose rate for gamma rays and neutron flux at the top of cover of reactor pool was studied as well. It was found that this relation is linear.

  17. Dose-mapping distribution around MNSR

    International Nuclear Information System (INIS)

    Jamal, M. H.; Khamis, I.

    2002-12-01

    The aim of this study is to establish the dose-rate map through the determination of radiological dose-rate levels in reactor hall, adjacent rooms, and outside the MNSR facility. Controlling dose rate to reactor operating personnel , dose map was established. The map covers time and distances in the reactor hall, during reactor operation at nominal power. Different measurement of dose rates in other areas of the reactor buildings was established. The maximum dose rate, during normal operation of the MNSR was 40 and 21 Sv/hr on the top of the reactor and near the pool fence, respectively. Whereas, gamma and neutron doses have not exceeded natural background in all rooms adjacent to the reactor hall or nearly buildings. The relation between the dose rate for gamma rays and neutron flux at the top of cover of reactor pool was studied as well. It was found that this relation is linear. (author)

  18. Simplified dose calculation method for mantle technique

    International Nuclear Information System (INIS)

    Scaff, L.A.M.

    1984-01-01

    A simplified dose calculation method for mantle technique is described. In the routine treatment of lymphom as using this technique, the daily doses at the midpoints at five anatomical regions are different because the thicknesses are not equal. (Author) [pt

  19. Organ doses from computerized tomography examinations

    Energy Technology Data Exchange (ETDEWEB)

    Janeczek, J.

    1995-12-31

    Estimates of mean organs doses from five typical computerized tomography (CT) examinations were obtained. Measurements were done using Rando-Alderson anthropomorphic phantom and thermoluminescent dosemeters (TLD). Radiation dose distributions within a phantom has been measured for each examination and results were used for organ dose calculation. Doses to organs specified by ICPR 60 Recommendations were measured for five CT scanners (CT/T8800, CT 9800, CT MAX - made by General Electric; CT 1200 SX - made by Picker; SOMATOM 2 - made by Siemens). Dose distributions from scattered radiation were measured and indicate that scattered radiation dose to thyroid and eye lens can be reduced by proper examination limits setting. The lowest mean organ doses were obtained from CT/T8800 scanner. More advanced scanners using high intensity continuous radiation were giving higher organ doses. (author). 23 refs, 6 figs, 13 tabs.

  20. Organ doses from computerized tomography examinations

    International Nuclear Information System (INIS)

    Janeczek, J.

    1995-01-01

    Estimates of mean organs doses from five typical computerized tomography (CT) examinations were obtained. Measurements were done using Rando-Alderson anthropomorphic phantom and thermoluminescent dosemeters (TLD). Radiation dose distributions within a phantom has been measured for each examination and results were used for organ dose calculation. Doses to organs specified by ICPR 60 Recommendations were measured for five CT scanners (CT/T8800, CT 9800, CT MAX - made by General Electric; CT 1200 SX - made by Picker; SOMATOM 2 - made by Siemens). Dose distributions from scattered radiation were measured and indicate that scattered radiation dose to thyroid and eye lens can be reduced by proper examination limits setting. The lowest mean organ doses were obtained from CT/T8800 scanner. More advanced scanners using high intensity continuous radiation were giving higher organ doses. (author). 23 refs, 6 figs, 13 tabs

  1. Calibration of dose meters used in radiotherapy

    International Nuclear Information System (INIS)

    1979-01-01

    This manual is a practical guide, not a comprehensive textbook, to the instrumentation and procedures necessary to calibrate a radiation dose meter used in clinical practice against a secondary standard dose meter

  2. Bayesian estimation of dose rate effectiveness

    International Nuclear Information System (INIS)

    Arnish, J.J.; Groer, P.G.

    2000-01-01

    A Bayesian statistical method was used to quantify the effectiveness of high dose rate 137 Cs gamma radiation at inducing fatal mammary tumours and increasing the overall mortality rate in BALB/c female mice. The Bayesian approach considers both the temporal and dose dependence of radiation carcinogenesis and total mortality. This paper provides the first direct estimation of dose rate effectiveness using Bayesian statistics. This statistical approach provides a quantitative description of the uncertainty of the factor characterising the dose rate in terms of a probability density function. The results show that a fixed dose from 137 Cs gamma radiation delivered at a high dose rate is more effective at inducing fatal mammary tumours and increasing the overall mortality rate in BALB/c female mice than the same dose delivered at a low dose rate. (author)

  3. Dose-rate dependence of thermoluminescence response

    International Nuclear Information System (INIS)

    McKeever, S.W.S.; Chen, R.; Groom, P.J.; Durrani, S.A.

    1980-01-01

    The previously observed dose-rate effect of thermoluminescence in quartz at high dose-rates is given at theoretical formulation. Computer calculations simulating the experimental conditions yield similar results to the experimental ones. (orig.)

  4. Generation of uniformly distributed dose points for anatomy-based three-dimensional dose optimization methods in brachytherapy.

    Science.gov (United States)

    Lahanas, M; Baltas, D; Giannouli, S; Milickovic, N; Zamboglou, N

    2000-05-01

    We have studied the accuracy of statistical parameters of dose distributions in brachytherapy using actual clinical implants. These include the mean, minimum and maximum dose values and the variance of the dose distribution inside the PTV (planning target volume), and on the surface of the PTV. These properties have been studied as a function of the number of uniformly distributed sampling points. These parameters, or the variants of these parameters, are used directly or indirectly in optimization procedures or for a description of the dose distribution. The accurate determination of these parameters depends on the sampling point distribution from which they have been obtained. Some optimization methods ignore catheters and critical structures surrounded by the PTV or alternatively consider as surface dose points only those on the contour lines of the PTV. D(min) and D(max) are extreme dose values which are either on the PTV surface or within the PTV. They must be avoided for specification and optimization purposes in brachytherapy. Using D(mean) and the variance of D which we have shown to be stable parameters, achieves a more reliable description of the dose distribution on the PTV surface and within the PTV volume than does D(min) and D(max). Generation of dose points on the real surface of the PTV is obligatory and the consideration of catheter volumes results in a realistic description of anatomical dose distributions.

  5. CONDOS-II, Radiation Dose from Consumer Product Distribution Chain

    International Nuclear Information System (INIS)

    1984-01-01

    1 - Description of problem or function: This code was developed under sponsorship of the Nuclear Regulatory Commission to serve as a tool for assessing radiation doses that may be associated with consumer products that contain radionuclides. The code calculates radiation dose equivalents resulting from user-supplied scenarios of exposures to radionuclides contained in or released from sources that contain radionuclides. Dose equivalents may be calculated to total body, skin surface, skeletal bone, testes, ovaries, liver, kidneys, lungs, and maximally exposed segments of the gastrointestinal tract from exposures via (1) direct, external irradiation by photons (including Bremsstrahlung) emitted from the source, (2) external irradiation by photons during immersion in air containing photon-emitting radionuclides that have escaped from the source, (3) internal exposures by all radiations emitted by inhaled radionuclides that have escaped from the source, and (4) internal exposures by all radiations emitted by ingested radionuclides that have escaped from the source. 2 - Method of solution: Organ dose equivalents are approximated in two ways, depending on the exposure type. For external exposures, energy specific organ-to-skin-surface dose conversion ratios are used to approximate dose equivalents to specific organs from doses calculated to a point on the skin surface. The organ-to-skin ratios are incorporated in organ- and nuclide-specific dose rate factors, which are used to approximate doses during immersion in contaminated air. For internal exposures, 50 year dose equivalents are calculated using organ- and nuclide-specific, 50 year dose conversion factors. Doses from direct, external exposures are calculated using the energy-specific dose conversion ratios, user supplied exposure conditions, and photon flux approximations for eleven source geometries. Available source geometries include: point, shielded and unshielded; line, shielded and unshielded; disk, shielded

  6. Dose estimation by biological methods

    International Nuclear Information System (INIS)

    Guerrero C, C.; David C, L.; Serment G, J.; Brena V, M.

    1997-01-01

    The human being is exposed to strong artificial radiation sources, mainly of two forms: the first is referred to the occupationally exposed personnel (POE) and the second, to the persons that require radiological treatment. A third form less common is by accidents. In all these conditions it is very important to estimate the absorbed dose. The classical biological dosimetry is based in the dicentric analysis. The present work is part of researches to the process to validate the In situ Fluorescent hybridation (FISH) technique which allows to analyse the aberrations on the chromosomes. (Author)

  7. Internal radiation dose of Indians

    International Nuclear Information System (INIS)

    Ranganathan, S.; Nagaratnam, A.; Sharma, U.C.

    2001-01-01

    The measurement of γ-rays from 40 K by whole-body counting provides a sensitive technique to estimate the body 40 K radioactivity. In India, right from the whole body counter (WBC) of Trombay in the early 1960s to the INMAS WBC of 1970s, some limited information has been available about the internal 40 K of Indians. However, information on 40 K dose with age and sex of Indians is scanty. Therefore, a systematic study was taken up to generate this information

  8. The philosophy of dose limitation

    International Nuclear Information System (INIS)

    Recht, P.

    1981-01-01

    The evolution of concepts and terms appearing in the European Rules of 15 July 1980 is briefly described. After a period where ''tolerance doses'' represent definite limits which should be respected, appears the concept of a ''as low as possible'' and ''as low as practicable'' level. The hypothesis that any exposure represents a risk which should be avoided is taken into account in the later evolution. As a consequence one has to examine the advantages and disadvantages in other words to make a cost-benefit analysis. This evolution leads to the concepts of justification and optimization used at the present time. (author)

  9. Dose dispenser for radioactive gas

    International Nuclear Information System (INIS)

    Horwitz, N.H.; Gutkowski, R.E.

    1977-01-01

    An activity metering apparatus for metering predetermined activities of radioactive gas from a supply ampul to dose vials is described. The apparatus includes a shielded ampul housing, a fine metering valve communicating with the ampul housing chamber, a shielded vial housing and a hypodermic needle communicating with the metering valve and received through an opening in the vial housing. A Geiger-Muller tube is adjustably supported opposite an opening in the vial housing, whereby the activity of the radioactive gas dispensed to a partially evacuated vial within the vial chamber may be read directly by a standard laboratory rate meter

  10. Dose limits cause unacceptable risk

    International Nuclear Information System (INIS)

    Collier, Sylvia.

    1985-01-01

    This paper on radiation dose limits for workers and the public discusses the following: Medical Research Council report; safety standards; risk assessment; deaths from cancers; biological radiation effects; UK legislation; low-level radiation; public concern; UKAEA staff survey; Ionising Radiations Regulations; United Nations Scientific Committee on Effects of Atomic Radiation; US studies on work force in nuclear establishments; problems of extrapolation; Japanese data from Hiroshima and Nagasaki; International Commission on Radiological Protection recommendations; studies on uranium miners; UK Health and Safety Executive; UK National Radiological Protection Board. (U.K.)

  11. Optimizing lithium dosing in hemodialysis

    DEFF Research Database (Denmark)

    Bjarnason, N H; Munkner, R; Kampmann, J P

    2006-01-01

    in which we developed an algorithm based on a 2-compartment distribution without elimination. The GFR estimate led to plasma concentrations 3-4 times lower than those anticipated. In contrast, the estimates based on V(d) and the algorithm derived from pharmacokinetic modeling led to comparable loading dose...... in this patient with no residual kidney function. We did not observe adverse effects related to this regimen, which was monitored from 18 days to 8 months of therapy, and the patient experienced relief from her severe depressive disorder. In conclusion, dialysis patients may be treated with lithium administrated...

  12. Optimized Dose Distribution of Gammamed Plus Vaginal Cylinders

    International Nuclear Information System (INIS)

    Supe, Sanjay S.; Bijina, T.K.; Varatharaj, C.; Shwetha, B.; Arunkumar, T.; Sathiyan, S.; Ganesh, K.M.; Ravikumar, M.

    2009-01-01

    Endometrial carcinoma is the most common malignancy arising in the female genital tract. Intracavitary vaginal cuff irradiation may be given alone or with external beam irradiation in patients determined to be at risk for locoregional recurrence. Vaginal cylinders are often used to deliver a brachytherapy dose to the vaginal apex and upper vagina or the entire vaginal surface in the management of postoperative endometrial cancer or cervical cancer. The dose distributions of HDR vaginal cylinders must be evaluated carefully, so that clinical experiences with LDR techniques can be used in guiding optimal use of HDR techniques. The aim of this study was to optimize dose distribution for Gammamed plus vaginal cylinders. Placement of dose optimization points was evaluated for its effect on optimized dose distributions. Two different dose optimization point models were used in this study, namely non-apex (dose optimization points only on periphery of cylinder) and apex (dose optimization points on periphery and along the curvature including the apex points). Thirteen dwell positions were used for the HDR dosimetry to obtain a 6-cm active length. Thus 13 optimization points were available at the periphery of the cylinder. The coordinates of the points along the curvature depended on the cylinder diameters and were chosen for each cylinder so that four points were distributed evenly in the curvature portion of the cylinder. Diameter of vaginal cylinders varied from 2.0 to 4.0 cm. Iterative optimization routine was utilized for all optimizations. The effects of various optimization routines (iterative, geometric, equal times) was studied for the 3.0-cm diameter vaginal cylinder. The effect of source travel step size on the optimized dose distributions for vaginal cylinders was also evaluated. All optimizations in this study were carried for dose of 6 Gy at dose optimization points. For both non-apex and apex models of vaginal cylinders, doses for apex point and three dome

  13. Microbial Biofilms: Persisters, Tolerance and Dosing

    Science.gov (United States)

    Cogan, N. G.

    2005-03-01

    Almost all moist surfaces are colonized by microbial biofilms. Biofilms are implicated in cross-contamination of food products, biofouling, medical implants and various human infections such as dental cavities, ulcerative colitis and chronic respiratory infections. Much of current research is focused on the recalcitrance of biofilms to typical antibiotic and antimicrobial treatments. Although the polymer component of biofilms impedes the penetration of antimicrobials through reaction-diffusion limitation, this does not explain the observed tolerance, it merely delays the action of the agent. Heterogeneities in growth-rate also slow the eradication of the bacteria since most antimicrobials are far less effective for non-growing, or slowly growing bacteria. This also does not fully describe biofilm tolerance, since heterogeneities arr primairly a result of nutrient consumption. In this investigation, we describe the formation of `persister' cells which neither grow nor die in the presence of antibiotics. We propose that the cells are of a different phenotype than typical bacterial cells and the expression of the phenotype is regulated by the growth rate and the antibiotic concentration. We describe several experiments which describe the dynamics of persister cells and which motivate a dosing protocol that calls for periodic dosing of the population. We then introduce a mathematical model, which describes the effect of such a dosing regiment and indicates that the relative dose/withdrawal times are important in determining the effectiveness of such a treatment. A reduced model is introduced and the similar behavior is demonstrated analytically.

  14. Fiber optics in high dose radiation fields

    International Nuclear Information System (INIS)

    Partin, J.K.

    1985-01-01

    A review of the behavior of state-of-the-art optical fiber waveguides in high dose (greater than or equal to 10 5 rad), steady state radiation fields is presented. The influence on radiation-induced transmission loss due to experimental parameters such as dose rate, total dose, irradiation history, temperature, wavelength, and light intensity, for future work in high dose environments are given

  15. Multiple anatomy optimization of accumulated dose

    International Nuclear Information System (INIS)

    Watkins, W. Tyler; Siebers, Jeffrey V.; Moore, Joseph A.; Gordon, James; Hugo, Geoffrey D.

    2014-01-01

    Purpose: To investigate the potential advantages of multiple anatomy optimization (MAO) for lung cancer radiation therapy compared to the internal target volume (ITV) approach. Methods: MAO aims to optimize a single fluence to be delivered under free-breathing conditions such that the accumulated dose meets the plan objectives, where accumulated dose is defined as the sum of deformably mapped doses computed on each phase of a single four dimensional computed tomography (4DCT) dataset. Phantom and patient simulation studies were carried out to investigate potential advantages of MAO compared to ITV planning. Through simulated delivery of the ITV- and MAO-plans, target dose variations were also investigated. Results: By optimizing the accumulated dose, MAO shows the potential to ensure dose to the moving target meets plan objectives while simultaneously reducing dose to organs at risk (OARs) compared with ITV planning. While consistently superior to the ITV approach, MAO resulted in equivalent OAR dosimetry at planning objective dose levels to within 2% volume in 14/30 plans and to within 3% volume in 19/30 plans for each lung V20, esophagus V25, and heart V30. Despite large variations in per-fraction respiratory phase weights in simulated deliveries at high dose rates (e.g., treating 4/10 phases during single fraction beams) the cumulative clinical target volume (CTV) dose after 30 fractions and per-fraction dose were constant independent of planning technique. In one case considered, however, per-phase CTV dose varied from 74% to 117% of prescription implying the level of ITV-dose heterogeneity may not be appropriate with conventional, free-breathing delivery. Conclusions: MAO incorporates 4DCT information in an optimized dose distribution and can achieve a superior plan in terms of accumulated dose to the moving target and OAR sparing compared to ITV-plans. An appropriate level of dose heterogeneity in MAO plans must be further investigated

  16. Dose-response relationship in clinical oncology

    International Nuclear Information System (INIS)

    Gehan, E.A.

    1984-01-01

    The relationship of dose (and dose rate) to response and toxicity in clinical oncology is reviewed. The concepts expressed by some authors in dose-response studies in animal and human systems are reviewed briefly. Dose rate and tactics of conducting clinical studies are reviewed for both radiotherapy and various types of chemotherapeutic treatment. Examples are given from clinical studies in Hodgkin's disease, acute leukemia, and breast cancer that may prove useful in planning future clinical studies

  17. Multiple anatomy optimization of accumulated dose

    Energy Technology Data Exchange (ETDEWEB)

    Watkins, W. Tyler, E-mail: watkinswt@virginia.edu; Siebers, Jeffrey V. [Department of Radiation Oncology, University of Virginia, Charlottesville, Virginia 22908 and Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia 23298 (United States); Moore, Joseph A. [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland 21231 and Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia 23298 (United States); Gordon, James [Henry Ford Health System, Detroit, Michigan 48202 and Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia 23298 (United States); Hugo, Geoffrey D. [Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia 23298 (United States)

    2014-11-01

    Purpose: To investigate the potential advantages of multiple anatomy optimization (MAO) for lung cancer radiation therapy compared to the internal target volume (ITV) approach. Methods: MAO aims to optimize a single fluence to be delivered under free-breathing conditions such that the accumulated dose meets the plan objectives, where accumulated dose is defined as the sum of deformably mapped doses computed on each phase of a single four dimensional computed tomography (4DCT) dataset. Phantom and patient simulation studies were carried out to investigate potential advantages of MAO compared to ITV planning. Through simulated delivery of the ITV- and MAO-plans, target dose variations were also investigated. Results: By optimizing the accumulated dose, MAO shows the potential to ensure dose to the moving target meets plan objectives while simultaneously reducing dose to organs at risk (OARs) compared with ITV planning. While consistently superior to the ITV approach, MAO resulted in equivalent OAR dosimetry at planning objective dose levels to within 2% volume in 14/30 plans and to within 3% volume in 19/30 plans for each lung V20, esophagus V25, and heart V30. Despite large variations in per-fraction respiratory phase weights in simulated deliveries at high dose rates (e.g., treating 4/10 phases during single fraction beams) the cumulative clinical target volume (CTV) dose after 30 fractions and per-fraction dose were constant independent of planning technique. In one case considered, however, per-phase CTV dose varied from 74% to 117% of prescription implying the level of ITV-dose heterogeneity may not be appropriate with conventional, free-breathing delivery. Conclusions: MAO incorporates 4DCT information in an optimized dose distribution and can achieve a superior plan in terms of accumulated dose to the moving target and OAR sparing compared to ITV-plans. An appropriate level of dose heterogeneity in MAO plans must be further investigated.

  18. Multiple anatomy optimization of accumulated dose.

    Science.gov (United States)

    Watkins, W Tyler; Moore, Joseph A; Gordon, James; Hugo, Geoffrey D; Siebers, Jeffrey V

    2014-11-01

    To investigate the potential advantages of multiple anatomy optimization (MAO) for lung cancer radiation therapy compared to the internal target volume (ITV) approach. MAO aims to optimize a single fluence to be delivered under free-breathing conditions such that the accumulated dose meets the plan objectives, where accumulated dose is defined as the sum of deformably mapped doses computed on each phase of a single four dimensional computed tomography (4DCT) dataset. Phantom and patient simulation studies were carried out to investigate potential advantages of MAO compared to ITV planning. Through simulated delivery of the ITV- and MAO-plans, target dose variations were also investigated. By optimizing the accumulated dose, MAO shows the potential to ensure dose to the moving target meets plan objectives while simultaneously reducing dose to organs at risk (OARs) compared with ITV planning. While consistently superior to the ITV approach, MAO resulted in equivalent OAR dosimetry at planning objective dose levels to within 2% volume in 14/30 plans and to within 3% volume in 19/30 plans for each lung V20, esophagus V25, and heart V30. Despite large variations in per-fraction respiratory phase weights in simulated deliveries at high dose rates (e.g., treating 4/10 phases during single fraction beams) the cumulative clinical target volume (CTV) dose after 30 fractions and per-fraction dose were constant independent of planning technique. In one case considered, however, per-phase CTV dose varied from 74% to 117% of prescription implying the level of ITV-dose heterogeneity may not be appropriate with conventional, free-breathing delivery. MAO incorporates 4DCT information in an optimized dose distribution and can achieve a superior plan in terms of accumulated dose to the moving target and OAR sparing compared to ITV-plans. An appropriate level of dose heterogeneity in MAO plans must be further investigated.

  19. Concepts of collective dose in radiological protection

    International Nuclear Information System (INIS)

    Lindell, B.

    1985-01-01

    The collective dose (S) is the product of the number of individuals exposed and their average radiation dose. ''Radiation dose'' is usually taken to be the effective dose equivalent (Hsub(E)) as defined by the ICRP. The unit of the collective dose is then the man.sievert (man.Sv). The following four applications of the collective dose are the most common: (a) in the assessment of the highest per caput dose rate in the future from a continued practice which exposes some critical group or the population as a whole to radiation; (b) in the limitation of present radiation sources, if it is believed that additional sources in the future may add to the per caput dose in a population so that it might reach unacceptable levels unless all sources are controlled at an early stage; (c) as an input to justification assessments, indicating the total detriment from a certain practice; and (d) as an input to optimization assessments as the basis for costing detriment in differential cost-benefit analyses of protection arrangements. It is sometimes said that the collective dose is a useful quantity only if the assumption of a non-threshold, linear dose-response relation is valid. This assumption is not always necessary. Applications (a) and (b) are possible without any assumption on the dose-response relationship at very low doses. Only applications (c) and (d) require the assumption of a non-threshold, linear dose-response relation. Some hesitation in using the collective dose originates in distrust in the biological assumptions implied by uses (c) and (d), but also in lack of confidence in the meaningfulness of collective doses that have been derived by adding dose contributions over very long time periods. However, none of the four applications (a) - (d) is by necessity related to extreme time scales. That problem mainly arises in the assessment of radioactive waste repositories

  20. Background dose subtraction in personnel dosimetry

    International Nuclear Information System (INIS)

    Picazo, T.; Llorca, N.; Alabau, J.

    1997-01-01

    In this paper it is proposed to consider the mode of the frequency distribution of the low dose dosemeters from each clinic that uses X rays as the background environmental dose that should be subtracted from the personnel dosimetry to evaluate the doses due to practice. The problems and advantages of this indirect method to estimate the environmental background dose are discussed. The results for 60 towns are presented. (author)

  1. Cervical cancer: intracavitary dose specification and prescription

    International Nuclear Information System (INIS)

    Potish, R.A.; Gerbi, B.J.

    1987-01-01

    Dose and volume specifications for reporting intracavitary therapy were analyzed according to criteria recommended by the International Commission on Radiation Units and Measurements (ICRU). Ninety Fletcher-Suit radium applications were studied to examine the validity of the assumptions of the ICRU and the merit of their routine reporting. It was demonstrated that the reporting recommendations were inconsistent with clinical prescription systems and added little to dose specification. The distinction between dose specification and dose prescription was stressed

  2. Should repository release criteria be based on collective dose, release limits, or individual doses?

    International Nuclear Information System (INIS)

    Channell, J.K.; Neill, R.H.

    1999-01-01

    The advantages and disadvantages of using each of 3 alternative methods (collective dose, release limits, and individual dose) as release criteria for determining long-term high level or transuranic waste repository performance of naturally occurring releases or man-made intrusions are evaluated. Each of the alternative approaches have positive aspects and each has uncertainties that require some arbitrary assumptions. A comparison of the numerical results from evaluating the three alternatives at WIPP leads to the conclusion that a collective dose is preferable because it is more site specific and allows consideration of the full effects of human intrusion. The main objection to release limits is they do not use site specific criteria to determine the radiological effect on local and regional populations. Individual dose criteria used and recommended in the United States have ignored doses to drillers and the public from wastes brought to the surface by human intrusion because these doses can be greater than acceptable limits. Also, there is disagreement about defining the location and lifestyle of the individual

  3. Assessment of organ equivalent doses and effective doses from diagnostic X-ray examinations

    International Nuclear Information System (INIS)

    Park, Sang Hyun

    2003-02-01

    The MIRD-type adult male, female and age 10 phantoms were constructed to evaluate organ equivalent dose and effective dose of patient due to typical diagnostic X-ray examination. These phantoms were constructed with external and internal dimensions of Korean. The X-ray energy spectra were generated with SPEC78. MCNP4B ,the general-purposed Monte Carlo code, was used. Information of chest PA , chest LAT, and abdomen AP diagnostic X-ray procedures was collected on the protocol of domestic hospitals. The results showed that patients pick up approximate 0.02 to 0.18 mSv of effective dose from a single chest PA examination, and 0.01 to 0.19 mSv from a chest LAT examination depending on the ages. From an abdomen AP examination, patients pick up 0.17 to 1.40 mSv of effective dose. Exposure time, organ depth from the entrance surface and X-ray beam field coverage considerably affect the resulting doses. Deviation among medical institutions is somewhat high, and this indicated that medical institutions should interchange their information and the need of education for medical staff. The methodology and the established system can be applied, with some expansion, to dose assessment for other medical procedures accompanying radiation exposure of patients like nuclear medicine or therapeutic radiology

  4. Comparison of dose length, area, and volume histograms as quantifiers of urethral dose in prostate brachytherapy

    International Nuclear Information System (INIS)

    Butler, Wayne M.; Merrick, Gregory S.; Dorsey, Anthony T.; Hagedorn, Brenda M.

    2000-01-01

    Purpose: To determine the magnitude of the differences between urethral dose-volume, dose-area, and dose-length histograms (DVH, DAH, and DLH, respectively, or DgH generically). Methods and Materials: Six consecutive iodine-125 ( 125 I) patients and 6 consecutive palladium-103 ( 103 Pd) patients implanted via a modified uniform planning approach were evaluated with day 0 computed tomography (CT)-based dosimetry. The urethra was identified by the presence of a urinary catheter and was hand drawn on the CT images with a mean radius of 3.3 ± 0.7 mm. A 0.1-mm calculation matrix was employed for the urethral volume and surface analysis, and urethral dose points were placed at the centroid of the urethra on each 5-mm CT slice. Results: Although individual patient DLHs were step-like, due to the sparseness of the data points, the composite urethral DLH, DAH, and DVHs were qualitatively similar. The DAH curve delivered more radiation than the other two curves at all doses greater than 90% of the prescribed minimum peripheral dose (mPD) to the prostate. In addition, the DVH curve was consistently higher than the DLH curve at most points throughout that range. Differences between the DgH curves were analyzed by integrating the difference curves between 0 and 200% of the mPD. The area-length, area-volume, and volume-length difference curves integrated in the ratio of 3:2:1. The differences were most pronounced near the inflection point of the DgH curves with mean A 125 , V 125 , and L 125 values of 36.6%, 31.4%, and 23.0%, respectively, of the urethra. Quantifiers of urethral hot spots such as D 10 , defined as the minimal dose delivered to the hottest 10% of the urethra, followed the same ranking: area analysis indicated the highest dose and length analysis, the lowest dose. D 10 was 148% and 136% of mPD for area and length evaluations, respectively. Comparing the two isotopes in terms of the amount of urethra receiving a given dose, 103 Pd implants were significantly

  5. Short- and Long-Term Effects of Prenatal Exposure to Iron Oxide Nanoparticles: Influence of Surface Charge and Dose on Developmental and Reproductive Toxicity

    Directory of Open Access Journals (Sweden)

    Kristin R. Di Bona

    2015-12-01

    Full Text Available Iron oxide nanoparticles (NPs are commonly utilized for biomedical, industrial, and commercial applications due to their unique properties and potential biocompatibility. However, little is known about how exposure to iron oxide NPs may affect susceptible populations such as pregnant women and developing fetuses. To examine the influence of NP surface-charge and dose on the developmental toxicity of iron oxide NPs, Crl:CD1(ICR (CD-1 mice were exposed to a single, low (10 mg/kg or high (100 mg/kg dose of positively-charged polyethyleneimine-Fe2O3-NPs (PEI-NPs, or negatively-charged poly(acrylic acid-Fe2O3-NPs (PAA-NPs during critical windows of organogenesis (gestation day (GD 8, 9, or 10. A low dose of NPs, regardless of charge, did not induce toxicity. However, a high exposure led to charge-dependent fetal loss as well as morphological alterations of the uteri (both charges and testes (positive only of surviving offspring. Positively-charged PEI-NPs given later in organogenesis resulted in a combination of short-term fetal loss (42% and long-term alterations in reproduction, including increased fetal loss for second generation matings (mice exposed in utero. Alternatively, negatively-charged PAA-NPs induced fetal loss (22% earlier in organogenesis to a lesser degree than PEI-NPs with only mild alterations in offspring uterine histology observed in the long-term.

  6. Reference dose levels for dental periapical radiography in Chonnam Province

    International Nuclear Information System (INIS)

    Han, Mi Ra; Kang, Byung Cheol; Yoon, Suk Ja; Lee, Jae Seo; Kim, Young Hee

    2009-01-01

    To establish reference doses of periapical radiography in Chonnam Province, Korea. The target-skin distances were measured for dental patient's 1235 exposures including 345 mandibular molar areas. Each periapical radiation exposure was simulated with exactly the same patients exposure parameters and the simulated radiation doses were measured utilizing Mult-O-Meter (Unfors Instruments, Billadal, Sweden). The measurements were done in 44 dental clinics with 49 dental x-ray sets in Chonnam Province for one or two weeks at each dental clinic during year 2006. The third quartile patient surface doses were 2.8 mGy for overall periapical exposures and 3.2 mGy for periapical mandibular molar exposures. The third quartile patient surface doses in Chonnam Province can be used as a guide to accepted clinical practice to reduce patient radiation exposure for the surveyed reference doses were below the recommended dental periapical radiography dose of 7 mGy by IAEA.

  7. Reference dose levels for dental periapical radiography in Chonnam Province

    Energy Technology Data Exchange (ETDEWEB)

    Han, Mi Ra; Kang, Byung Cheol; Yoon, Suk Ja [Department of Oral and Maxillofacial Radiology, College of Dentistry, Dental Science Research Institute, Chonnam National University, Gwangju (Korea, Republic of); Lee, Jae Seo [Department of Oral and Maxillofacial Radiology, Chonnan National University Hospital, Gwangju (Korea, Republic of); Kim, Young Hee [Department of Oral and Maxillofacial Radiology, Hallym University Sacred Heart Hospital, Chuncheon (Korea, Republic of)

    2009-12-15

    To establish reference doses of periapical radiography in Chonnam Province, Korea. The target-skin distances were measured for dental patient's 1235 exposures including 345 mandibular molar areas. Each periapical radiation exposure was simulated with exactly the same patients exposure parameters and the simulated radiation doses were measured utilizing Mult-O-Meter (Unfors Instruments, Billadal, Sweden). The measurements were done in 44 dental clinics with 49 dental x-ray sets in Chonnam Province for one or two weeks at each dental clinic during year 2006. The third quartile patient surface doses were 2.8 mGy for overall periapical exposures and 3.2 mGy for periapical mandibular molar exposures. The third quartile patient surface doses in Chonnam Province can be used as a guide to accepted clinical practice to reduce patient radiation exposure for the surveyed reference doses were below the recommended dental periapical radiography dose of 7 mGy by IAEA.

  8. Simulation of computed tomography dose based on voxel phantom

    Science.gov (United States)

    Liu, Chunyu; Lv, Xiangbo; Li, Zhaojun

    2017-01-01

    Computed Tomography (CT) is one of the preferred and the most valuable imaging tool used in diagnostic radiology, which provides a high-quality cross-sectional image of the body. It still causes higher doses of radiation to patients comparing to the other radiological procedures. The Monte-Carlo method is appropriate for estimation of the radiation dose during the CT examinations. The simulation of the Computed Tomography Dose Index (CTDI) phantom was developed in this paper. Under a similar conditions used in physical measurements, dose profiles were calculated and compared against the measured values that were reported. The results demonstrate a good agreement between the calculated and the measured doses. From different CT exam simulations using the voxel phantom, the highest absorbed dose was recorded for the lung, the brain, the bone surface. A comparison between the different scan type shows that the effective dose for a chest scan is the highest one, whereas the effective dose values during abdomen and pelvis scan are very close, respectively. The lowest effective dose resulted from the head scan. Although, the dose in CT is related to various parameters, such as the tube current, exposure time, beam energy, slice thickness and patient size, this study demonstrates that the MC simulation is a useful tool to accurately estimate the dose delivered to any specific organs for patients undergoing the CT exams and can be also a valuable technique for the design and the optimization of the CT x-ray source.

  9. The usefulness of metal markers for CTV-based dose prescription in high-dose-rate interstitial brachytherapy

    International Nuclear Information System (INIS)

    Yoshida, Ken; Mitomo, Masanori; Nose, Takayuki; Koizumi, Masahiko; Nishiyama, Kinji; Yoshida, Mineo

    2002-01-01

    We employ a clinical target volume (CTV)-based dose prescription for high-dose-rate (HDR) interstitial brachytherapy. However, it is not easy to define CTV and organs at risk (OAR) from X-ray film or CT scanning. To solve this problem, we have utilized metal markers since October 1999. Moreover, metal markers can help modify dose prescription. By regulating the doses to the metal markers, refining the dose prescription can easily be achieved. In this research, we investigated the usefulness of the metal markers. Between October 1999 and May 2001, 51 patients were implanted with metal markers at Osaka Medical Center for Cancer and Cardiovascular Diseases (OMCC), Osaka National Hospital (ONH) and Sanda City Hospital (SCH). Forty-nine patients (head and neck: 32; pelvis: 11; soft tissue: 3; breast: 3) using metal markers were analyzed. During operation, we implanted 179 metal markers (49 patients) to CTV and 151 markers (26 patients) to OAR. At treatment planning, CTV was reconstructed judging from the metal markers, applicator position and operation records. Generally, we prescribed the tumoricidal dose to an isodose surface that covers CTV. We also planned to limit the doses to OAR lower than certain levels. The maximum normal tissue doses were decided 80%, 150%, 100%, 50% and 200% of the prescribed doses for the rectum, the urethra, the mandible, the skin and the large vessel, respectively. The doses to the metal markers using CTV-based dose prescription were generated. These were compared with the doses theoretically calculated with the Paris system. Treatment results were also investigated. The doses to the 158 metal markers (42 patients) for CTV were higher than ''tumoricidal dose''. In 7 patients, as a result of compromised dose prescription, 9 markers were lower than the tumoricidal dose. The other 12 markers (7%) were excluded from dose evaluation because they were judged as miss-implanted. The doses to the 142 metal markers (24 patients) for OAR were lower

  10. Maternal methadone dosing schedule and fetal neurobehavior

    Science.gov (United States)

    Jansson, Lauren M.; DiPietro, Janet A.; Velez, Martha; Elko, Andrea; Knauer, Heather; Kivlighan, Katie T.

    2008-01-01

    Objective Daily methadone maintenance is the standard of care for opiate dependency during pregnancy. Previous research has indicated that single-dose maternal methadone administration significantly suppresses fetal neurobehaviors. The purpose of this study was to determine if split-dosing would have less impact on fetal neurobehavior than single-dose administration. Methods Forty methadone-maintained women were evaluated at peak and trough maternal methadone levels on single- and split-dosing schedules. Monitoring sessions occurred at 36 and 37 weeks gestation in a counterbalanced study design. Fetal measures included heart rate, variability, accelerations, motor activity and fetal movement-heart rate coupling (FM-FHR). Maternal measures included heart period, variability, skin conductance, respiration and vagal tone. Repeated measure analysis of variance was used to evaluate within-subject changes between split- and single-dosing regimens. Results All fetal neurobehavioral parameters were suppressed by maternal methadone administration, regardless of dosing regimen. Fetal parameters at peak were significantly lower during single vs. split methadone administration. FM-FHR coupling was less suppressed from trough to peak during split-dosing vs. single-dosing. Maternal physiologic parameters were generally unaffected by dosing condition. Conclusion Split- dosed fetuses displayed less neurobehavioral suppression from trough to peak maternal methadone levels as compared to single-dosed fetuses. Split-dosing may be beneficial for methadone-maintained pregnant women. PMID:19085624

  11. Failure-probability driven dose painting

    DEFF Research Database (Denmark)

    Vogelius, Ivan R; Håkansson, Katrin; Due, Anne K

    2013-01-01

    To demonstrate a data-driven dose-painting strategy based on the spatial distribution of recurrences in previously treated patients. The result is a quantitative way to define a dose prescription function, optimizing the predicted local control at constant treatment intensity. A dose planning study...

  12. A dose monitoring system for dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chena; Lee, Sam Sun; Kim, Jo Eun; Huh, Kyung Hoe; Yi, Woo Jin; Heo, Min Suk; Choi, Soon Chul [Dept. of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University, Seoul (Korea, Republic of); Symkhampha, Khanthaly [Dept. of Oral and Maxillofacial Radiology, Department of Basic Science, Faculty of Dentistry, University of Health Sciences, Vientiane (Lao People' s Democratic Republic); Lee, Woo Jin [Dept. of Interdisciplinary Program in Radiation, Applied Life Sciences Major, College of Medicine, BK21, and Dental Research Institute, Seoul National University, Seoul (Korea, Republic of); Yeom, Heon Young [School of Computer Science Engineering, Seoul National University, Seoul (Korea, Republic of)

    2016-06-15

    The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose.

  13. A dose monitoring system for dental radiography

    International Nuclear Information System (INIS)

    Lee, Chena; Lee, Sam Sun; Kim, Jo Eun; Huh, Kyung Hoe; Yi, Woo Jin; Heo, Min Suk; Choi, Soon Chul; Symkhampha, Khanthaly; Lee, Woo Jin; Yeom, Heon Young

    2016-01-01

    The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose

  14. The definition of the individual dose equivalent

    International Nuclear Information System (INIS)

    Ehrlich, Margarete

    1986-01-01

    A brief note examines the choice of the present definition of the individual dose equivalent, the new operational dosimetry quantity for external exposure. The consequences of the use of the individual dose equivalent and the danger facing the individual dose equivalent, as currently defined, are briefly discussed. (UK)

  15. Gonadal dose in routine diagnostic examinations

    International Nuclear Information System (INIS)

    Weber, J.; Koen, J.A.; Akkermans, J.A.

    1974-01-01

    Gonadal doses caused by stray radiation produced during radiodiagnostic investigations were measured with thermoluminescent dosemeters in various hospitals in the Netherlands. Significantly different gonadal doses were measured depending upon the hospital where the investigations were carried out. The mean dose of an examination type in one country can only be determined with any accuracy if measurements in a large number of hospitals are performed

  16. Endorectal high dose rate brachytherapy quality assurance

    International Nuclear Information System (INIS)

    Devic, S.; Vuong, T.; Evans, M.; Podgorsak, E.

    2008-01-01

    We describe our quality assurance method for preoperative high dose rate (HDR) brachytherapy of endorectal tumours. Reproduction of the treatment planning dose distribution on a daily basis is crucial for treatment success. Due to the cylindrical symmetry, two types of adjustments are necessary: applicator rotation and dose distribution shift along the applicator axis. (author)

  17. Dose mapping role in gamma irradiation industry

    International Nuclear Information System (INIS)

    Noriah Mod Ali; John Konsoh Sangau; Mazni Abd Latif

    2002-01-01

    In this studies, the role of dosimetry activity in gamma irradiator was discussed. Dose distribution in the irradiator, which is a main needs in irradiator or chamber commissioning. This distribution data were used to confirm the dosimetry parameters i.e. exposure time, maximum and minimum dose map/points, and dose distribution - in which were used as guidelines for optimum product irradiation. (Author)

  18. Estimation of exposed dose, 1

    International Nuclear Information System (INIS)

    Okajima, Shunzo

    1976-01-01

    Radioactive atomic fallouts in Nishiyama district of Nagasaki Prefecture are reported on the basis of the survey since 1969. In 1969, the amount of 137 Cs in the body of 50 inhabitants in Nishiyama district was measured using human counter, and was compared with that of non-exposured group. The average value of 137 Cs (pCi/kg) was higher in inhabitants in Nishiyama district (38.5 in men and 24.9 in females) than in the controls (25.5 in men and 14.9 in females). The resurvey in 1971 showed that the amount of 137 Cs was decreased to 76% in men and 60% in females. When the amount of 137 Cs in the body was calculated from the chemical analysis of urine, it was 29.0 +- 8.2 in men and 29.4 +- 26.2 in females in Nishiyama district, and 29.9 +- 8.2 in men and 29.4 +- 11.7 in females in the controls. The content of 137 Cs in soils and crops (potato etc.) was higher in Nishiyama district than in the controls. When the internal exposure dose per year was calculated from the amount of 137 Cs in the body in 1969, it was 0.29 mrad/year in men and 0.19 mrad/year in females. Finally, the internal exposure dose immediately after the explosion was estimated. (Serizawa, K.)

  19. Patient doses in interventional cardiology

    International Nuclear Information System (INIS)

    Carrera, F.; Ojeda, C.; Ruiz-Cruces, R.; Francisco Diaz, J.; Sanchez, A.; Tort, I.

    2001-01-01

    Cardiovascular diseases are the first cause of death in Spain. The most usual procedures in interventional cardiology are coronariography and PTCA. The first is a diagnostic technique, and the second one is interventional. Our goal has been to study procedures made during the first six months in the Interventional Cardiology Unit of the Juan Ramon Jimenez Hospital (Huelva-Spain), taking into account radiation protection issues. We have studied 178 patients; 145 of them underwent coronariography, and 33 of the patients had PTCA too. Every case was analyzed taking into account technical and dosimetric parameters. We show parameters values gathered: Diagnostic techniques (valvular and non-valvular patients), and interventional techniques (coronariography and PTCA in different or in the same intervention). Higher doses were obtained with valvular patients, although the number of frames was similar. Attending to therapeutic procedures, the highest values were gotten with the 'double' interventions. Interventional procedures exceed in 60% doses gotten in diagnostic studies: this is because of the number of series and number of frames per series. Similar values obtained by other authors have been gotten. (author)

  20. Radiation dose during mammography using various recording systems

    International Nuclear Information System (INIS)

    Heep, H.; Buelow-Johansen, T.; Klemencic, J.; Wegwitz, J.; Stadtkrankenhaus Offenbach

    1978-01-01

    Patient dose during mammography for various recording systems, such as film, film-screen combination and xeromammography was measured by thermoluminescent densitometers. In the first set of experiments we measured dose per exposure, in a second set total surface dose at five points on the breast, using the following combintions: a) Two industrial film exposures and one xeromammographic exposure. b) two film-screen exposures and one xeromammographic exposure. c) One industrial film and two xeromammographic exposures. (orig.) [de

  1. Field measurement and interpretation of beta doses and dose rates

    International Nuclear Information System (INIS)

    Selby, J.M.; Swinth, K.L.; Hooker, C.D.; Kenoyer, J.L.

    1983-01-01

    A large number of portable survey instruments employing G.M., ionization chamber, and scintillation detectors used for gamma measurements are also used for monitoring in beta fields by using removable shields to separate the beta and gamma components of the radiation field. The difference does not correspond to an absorbed dose rate for the beta field due to a variety of factors. Among these factors are the dependence on beta energy, source-detector geometries, mixed fields and variable ambient conditions. Attempting to use such measurements directly can lead to errors as high as a factor of 100. Appropriate calibrations and correction factors can be used to reduce the errors in beta measurements to a tolerable level

  2. Isobio software: biological dose distribution and biological dose volume histogram from physical dose conversion using linear-quadratic-linear model.

    Science.gov (United States)

    Jaikuna, Tanwiwat; Khadsiri, Phatchareewan; Chawapun, Nisa; Saekho, Suwit; Tharavichitkul, Ekkasit

    2017-02-01

    To develop an in-house software program that is able to calculate and generate the biological dose distribution and biological dose volume histogram by physical dose conversion using the linear-quadratic-linear (LQL) model. The Isobio software was developed using MATLAB version 2014b to calculate and generate the biological dose distribution and biological dose volume histograms. The physical dose from each voxel in treatment planning was extracted through Computational Environment for Radiotherapy Research (CERR), and the accuracy was verified by the differentiation between the dose volume histogram from CERR and the treatment planning system. An equivalent dose in 2 Gy fraction (EQD 2 ) was calculated using biological effective dose (BED) based on the LQL model. The software calculation and the manual calculation were compared for EQD 2 verification with pair t -test statistical analysis using IBM SPSS Statistics version 22 (64-bit). Two and three-dimensional biological dose distribution and biological dose volume histogram were displayed correctly by the Isobio software. Different physical doses were found between CERR and treatment planning system (TPS) in Oncentra, with 3.33% in high-risk clinical target volume (HR-CTV) determined by D 90% , 0.56% in the bladder, 1.74% in the rectum when determined by D 2cc , and less than 1% in Pinnacle. The difference in the EQD 2 between the software calculation and the manual calculation was not significantly different with 0.00% at p -values 0.820, 0.095, and 0.593 for external beam radiation therapy (EBRT) and 0.240, 0.320, and 0.849 for brachytherapy (BT) in HR-CTV, bladder, and rectum, respectively. The Isobio software is a feasible tool to generate the biological dose distribution and biological dose volume histogram for treatment plan evaluation in both EBRT and BT.

  3. DISRUPTIVE EVENT BIOSPHERE DOSE CONVERSION FACTOR ANALYSIS

    International Nuclear Information System (INIS)

    M.A. Wasiolek

    2005-01-01

    ash exposure scenario and the dose factors for calculating inhalation doses during volcanic eruption (eruption phase of the volcanic event). For the volcanic ash exposure scenario, the mode of radionuclide release into the biosphere is a volcanic eruption through the repository with the resulting entrainment of contaminated waste in the tephra and the subsequent atmospheric transport and dispersion of contaminated material in the biosphere. The biosphere process model for this scenario uses the surface deposition of contaminated ash as the source of radionuclides in the biosphere. The initial atmospheric transport and dispersion of the ash as well as its subsequent redistribution by fluvial and aeolian processes are not addressed within the biosphere model. These processes influence the value of the source term that is calculated elsewhere and then combined with the BDCFs in the TSPA model to calculate expected dose to the receptor

  4. Dose rate visualization of radioisotope thermoelectric generators

    International Nuclear Information System (INIS)

    Schwarz, R.A.; Kessler, S.F.; Tomaszewski, T.A.

    1995-09-01

    Advanced visualization techniques can be used to investigate gamma ray and neutron dose rates around complex dose rate intensive operations. A method has been developed where thousands of dose points are calculated using the MCNP(Monte Carlo N-Particle) computer code and then displayed to create color contour plots of the dose rate for complex geometries. Once these contour plots are created, they are sequenced together creating an animation to dynamically show how the dose rate changes with changes in the geometry or source over time

  5. Discuss on luminescence dose data analysis technology

    International Nuclear Information System (INIS)

    Ma Xinhua; Xiao Wuyun; Ai Xianyun; Shi Zhilan; Liu Ying

    2009-01-01

    This article describes the development of luminescence dose data measurement and processing technology. General design planning of luminescence dose data measurement and processing technology is put forward with the diverse demands. The emphasis is focused on dose data processing method, luminescence curve analysis method, using of network, mechanics of communication among computers, data base management system of individual dose in this paper. The main methods and skills used in this technology as well as their advantages are also discussed. And it offers general design references for development luminescence dose data processing software. (authors)

  6. Patient radiation doses from enteroclysis examinations

    International Nuclear Information System (INIS)

    Hart, D.; Wall, B.F.; Haggett, P.J.; Boardman, P.; Nolan, D.J.

    1994-01-01

    Data relating to patient dose have been acquired for enteroclysis examinations (small bowel enemas) performed at the John Radcliffe Hospital, Oxford, on 23 adult patients. Dose-area products, fluoroscopy times and the number of radiographs taken are used to compare the examination procedure at the Hospital with enteroclysis and barium follow-throughs performed elsewhere. The mean dose-area product for the 23 examinations was 6.8 Gy cm 2 and the mean effective dose was estimated to be 1.5 mSv. These doses are intermediate between those arising from barium meals and barium enemas performed in the same room. (author)

  7. Dose rate visualization of radioisotope thermoelectric generators

    International Nuclear Information System (INIS)

    Schwarz, R.A.; Kessler, S.F.; Tomaszewski, T.A.

    1996-01-01

    Advanced visualization techniques can be used to investigate gamma ray and neutron dose rates around complex dose rate intensive operations. A method has been developed where thousands of dose points are calculated using the MCNP (Monte Carlo N-Particle) computer code (Briesmeister 1993) and then displayed to create color contour plots of the dose rate for complex geometries. Once these contour plots are created, they are sequenced together creating an animation to dynamically show how the dose rate changes with changes in the geometry or source over time. copyright 1996 American Institute of Physics

  8. Dose Rate Effects in Linear Bipolar Transistors

    Science.gov (United States)

    Johnston, Allan; Swimm, Randall; Harris, R. D.; Thorbourn, Dennis

    2011-01-01

    Dose rate effects are examined in linear bipolar transistors at high and low dose rates. At high dose rates, approximately 50% of the damage anneals at room temperature, even though these devices exhibit enhanced damage at low dose rate. The unexpected recovery of a significant fraction of the damage after tests at high dose rate requires changes in existing test standards. Tests at low temperature with a one-second radiation pulse width show that damage continues to increase for more than 3000 seconds afterward, consistent with predictions of the CTRW model for oxides with a thickness of 700 nm.

  9. Dose-response association between hepatitis B surface antigen levels and liver cancer risk in Chinese men and women.

    Science.gov (United States)

    Yang, Yang; Gao, Jing; Li, Hong-Lan; Zheng, Wei; Yang, Gong; Zhang, Wei; Ma, Xiao; Tan, Yu-Ting; Rothman, Nathaniel; Gao, Yu-Tang; Chow, Wong-Ho; Shu, Xiao-Ou; Xiang, Yong-Bing

    2016-07-15

    We aimed at evaluating the risk of liver cancer in different levels of HBsAg among Chinese men and women. We carried out a nested case-control study including 363 cases and 3,511 controls in two population-based cohorts in Shanghai. Plasma samples collected at enrollment were quantified for HBsAg levels using the Architect QT assay. Conditional logistic regression was performed to estimate the odds ratios (ORs) and 95% confidence intervals (95% CIs) for liver cancer, with adjustment for potential confounders. HBsAg was detected in 6.29% of control subjects overall (7.02% in men and 4.98% in women). HBsAg levels were positively associated with liver cancer risk in a dose-response manner (ptrend  women. In men, the adjusted ORs increased from 7.27 (95% CI: 3.49-15.15) at the lowest detectable level of HBsAg (5-9 IU/ml) to 7.16 (95% CI: 3.21-15.96), 34.30 (95% CI: 16.94-69.44), and 47.33 (95% CI: 23.50-95.34) at the highest level of HBsAg (≥1,000 IU/ml) compared to those negative for HBsAg. The corresponding ORs were much lower for women, from 1.37 (95% CI: 0.25-7.47), 3.81 (95% CI: 1.09-13.28), 7.36 (95% CI: 2.41-22.46) and 16.86 (95% CI: 7.24-39.27), respectively. HBsAg quantification has potential to distinguish individuals at different risks of liver cancer. Men with the lowest detectable level of HBsAg should still pay attention to their liver cancer risks, but those with a higher level may be given a higher priority in future liver cancer surveillance program. © 2016 UICC.

  10. Entrance and peripheral dose measurements during radiotherapy

    International Nuclear Information System (INIS)

    Sulieman, A.; Kappas, K.; Theodorou, K.

    2008-01-01

    In vivo dosimetry of entrance dose was performed using thermoluminescent dosimeters (TLD) in order to evaluate the clinical application of the build up caps in patient dose measurements and for different treatment techniques. Peripheral dose (thyroid and skin) was measured for patients during breast radiotherapy to evaluate the probability of secondary cancer induction. TLD-100 chips were used with different Copper build up caps (for 6 MV and 15 MV photon beams from two linear accelerators. Entrance doses were measured for patients during radiotherapy course for breast, head and neck, abdomen and pelvis malignancies. The measured entrance dose for the different patients for 6 MV beams is found to be within the ±2.6% compared to the dose derived from theoretical estimation (normalized dose at D max ). The same measurements for 15 MV beams are found to be ±3 %. The perturbation value can reach up to 20% of the D max , which acts as a limitation for entrance dose measurements. An average thyroid skin dose of 3.7% of the prescribed dose was measured per treatment session while the mean skin dose breast treatment session is estimated to be 42% of D max , for both internal and external fields. These results are comparable in those of the in vivo of reported in literature. The risk of fatality due to thyroid cancer per treatment course is 3x10 -3

  11. On uncertainties in definition of dose equivalent

    International Nuclear Information System (INIS)

    Oda, Keiji

    1995-01-01

    The author has entertained always the doubt that in a neutron field, if the measured value of the absorbed dose with a tissue equivalent ionization chamber is 1.02±0.01 mGy, may the dose equivalent be taken as 10.2±0.1 mSv. Should it be 10.2 or 11, but the author considers it is 10 or 20. Even if effort is exerted for the precision measurement of absorbed dose, if the coefficient being multiplied to it is not precise, it is meaningless. [Absorbed dose] x [Radiation quality fctor] = [Dose equivalent] seems peculiar. How accurately can dose equivalent be evaluated ? The descriptions related to uncertainties in the publications of ICRU and ICRP are introduced, which are related to radiation quality factor, the accuracy of measuring dose equivalent and so on. Dose equivalent shows the criterion for the degree of risk, or it is considered only as a controlling quantity. The description in the ICRU report 1973 related to dose equivalent and its unit is cited. It was concluded that dose equivalent can be considered only as the absorbed dose being multiplied by a dimensionless factor. The author presented the questions. (K.I.)

  12. Guidance levels, achievable doses and expectation levels

    International Nuclear Information System (INIS)

    Li, Lianbo; Meng, Bing

    2002-01-01

    The National Radiological Protection Board (NRPB), the International Atomic Energy Agency (IAEA) and the Commission of the European Communities (CEC) published their guidance levels and reference doses for typical X-ray examination and nuclear medicine in their documents in 1993, 1994 and 1996 respectively. From then on, the concept of guidance levels or reference doses have been applied to different examinations in the field of radiology and proved to be effective for reduction of patient doses. But the guidance levels or reference doses are likely to have some shortcomings and can do little to make further reduction of patient dose in the radiology departments where patient dose are already below them. For this reason, the National Radiological Protection Board (NRPB) proposed a concept named achievable doses which are based on the mean dose observed for a selected sample of radiology departments. This paper will review and discuss the concept of guidance levels and achievable doses, and propose a new concept referred to as Expectation Levels that will encourage the radiology departments where patient dose are already below the guidance levels to keep patient dose as low as reasonably achievable. Some examples of the expectation levels based on the data published by a few countries are also illustrated in this paper

  13. Considering job-related doses in Europe

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    As part of its role of safeguarding nuclear workers the Commission of the European Community has created a European data bank on job-related doses. The data bank is intended to correlate jobs and workers doses and is a useful instrument to observe the collected doses of workers in nuclear power plants. Set up in 1980, the database covers doses in PWRs and BWRs. To create it a questionnaire is distributed to plant operators. The database responses provide information on (i) Trends in total collective doses, including those for some ancillary jobs. It is possible to see trends by calendar year and by fuel cycle number. (ii) Other trends such as dose in terms of installed power or dose in terms of power station design. (iii) Dose differences between power stations, normalized against the differences in dose rates. This is only possible for PWRs that monitor dose rates using the EPRI standard monitoring programme. (vi) The relative dose rate in each plant for a defined job. The questionnaire is not perfectly adapted to all the working criteria in nuclear power stations but it is an effective tool for implementing radiation protection. (author)

  14. Peripheral dose outside applicators in electron beams

    International Nuclear Information System (INIS)

    Chow, James C L; Grigorov, Grigor N

    2006-01-01

    The peripheral dose outside the applicators in electron beams was studied using a Varian 21 EX linear accelerator. To measure the peripheral dose profiles and point doses for the applicator, a solid water phantom was used with calibrated Kodak TL films. Peak dose spot was observed in the 4 MeV beam outside the applicator. The peripheral dose peak was very small in the 6 MeV beam and was ignorable at higher energies. Using the 10 x 10 cm 2 cutout and applicator, the dose peak for the 4 MeV beam was about 12 cm away from the field central beam axis (CAX) and the peripheral dose profiles did not change with depths measured at 0.2, 0.5 and 1 cm. The peripheral doses and profiles were further measured by varying the angle of obliquity, cutout and applicator size for the 4 MeV beam. The local peak dose was increased with about 3% per degree angle of obliquity, and was about 1% of the prescribed dose (angle of obliquity equals zero) at 1 cm depth in the phantom using the 10 x 10 cm 2 cutout and applicator. The peak dose position was also shifted 7 mm towards the CAX when the angle of obliquity was increased from 0 to 15 deg. (note)

  15. Cytogenetic effects of low-dose radiation

    International Nuclear Information System (INIS)

    Metalli, P.

    1983-01-01

    The effects of ionizing radiation on chromosomes have been known for several decades and dose-effect relationships are also fairly well established in the mid- and high-dose and dose-rate range for chromosomes of mammalian cells. In the range of low doses and dose rates of different types of radiation few data are available for direct analysis of the dose-effect relationships, and extrapolation from high to low doses is still the unavoidable approach in many cases of interest for risk assessment. A review is presented of the data actually available and of the attempts that have been made to obtain possible generalizations. Attention is focused on some specific chromosomal anomalies experimentally induced by radiation (such as reciprocal translocations and aneuploidies in germinal cells) and on their relevance for the human situation. (author)

  16. Dose evaluation in diagnostic for computerized tomography

    International Nuclear Information System (INIS)

    Flores, W.; Borges, J.C.; Mota, H.

    1998-01-01

    The patients which are subjected to computerized tomography tests are exposed to relatively high doses given as result doses on organs that are not matter to test. It was realized a dose levels raising in patients subjected to tests by T C, utilizing to measure this magnitude, TLD-100 thermoluminescent dosemeters which were put directly on the patient, in eye regions, thyroid, breast and navel; founding doses fluctuating between 29.10-49.39 mGy in organs examined and dose values between 0.21-29.10 mGy for organs that no matter to test. The applications of ionizing radiations in medicine do not have dose limits, but paying attention to the radiological protection optimization principle, it is recommended the use of clothes to anti-rays protection for zones not examined, getting with this to reduce the level doses as low as possible, without this to diminish the test quality. (Author)

  17. The concept of the effective dose

    International Nuclear Information System (INIS)

    Jacobi, W.

    1975-01-01

    Irradiation of the human body by external or internal sources leads mostly to a simultaneous exposure of several organs. However, so far no clear and consistent recommendations for the combination of organ doses and the assessment of an exposure limit under such irradiation conditions are available. Following a proposal described in ICRP-publication 14 one possible concept for the combination of organ doses is discussed in this paper. This concept is based on the assumption that at low doses the total radiation detriment to the exposed person is given by the sum of radiation detriments to the single organs. Taking into account a linear dose-risk relationship, the sum of weighted organ doses leads to the definition of an 'Effective Dose'. The applicability and consequences of this 'Effective Dose Concept' are discussed especially with regard to the assessment of the maximum permissible intake of radionuclides into the human body and the combination of external and internal exposure. (orig.) [de

  18. Salivary gland doses from dental radiographic exposures

    International Nuclear Information System (INIS)

    Hoshi, Masaharu; Kato, Kazuo; Wada, Takuro; Antoku, Shigetoshi; Russell, W.J.

    1989-01-01

    Salivary gland doses incurred during dental radiography were measured by phantom dosimetry, and these dose data and data obtained during a two-week survey of Hiroshima and Nagasaki dental hospitals and clinics were used to estimate the respective doses to members of the populations of the two cities. The results obtained were used to supplement previously determined doses to the thyroid gland, lens, and pituitary gland from dental radiography. No significant differences in doses were observed by age, sex or city. Doses to the salivary glands during dental radiography are probably not sufficiently large to cause bias in assessments of atomic bomb survivors for late radiation effects. However, the steadily increasing use of dental radiography underscores the need for continued monitoring of dental radiography doses in the interests of these assessments. (author)

  19. Routine monitoring of eye dose; and reply

    Energy Technology Data Exchange (ETDEWEB)

    Palmer, K; Jeans, S P; Faulkner, K; Bardsley, R A; Love, H G

    1985-12-01

    This letter briefly reports the assessment at Papworth Hospital of the feasibility of monitoring eye doses of staff using a film badge worn on the shoulder in addition to the badge worn under the lead apron. For three consecutive months hand and eye (forehead) dose were monitored using TLDs, while shoulder and body dose, recorded under the lead apron, were measured with film badges. For the four doctors monitored, (two radiologists and two cardiologists) the shoulder badge somewhat overestimated the eye dose. In the case of nurses, the dose recorded by the shoulder badge was of a similar order to the TLD-recorded eye dose. The reply from the Christie Hospital at Manchester comments on the use of the shoulder badge and contends that the use of forehead dosemeters to measure eye dose is to be preferred whenever possible.

  20. Hand Dose in Nuclear Medicine Staff Members

    International Nuclear Information System (INIS)

    Taha, T.M.; Shahein, A.Y.; Hassan, R.

    2009-01-01

    Measurement of the hand dose during preparation and injection of radiopharmaceuticals is useful in the assessment of the extremity doses received by nuclear medicine personnel. Hand radiation doses to the occupational workers that handling 99m Tc-labeled compounds, 131 I for diagnostic in nuclear medicine were measured by thermoluminescence dosimetry. A convenient method is to use a TLD ring dosimeter for measuring doses of the diagnostic units of different nuclear medicine facilities . Their doses were reported in millisieverts that accumulated in 4 weeks. The radiation doses to the hands of nuclear medicine staff at the hospitals under study were measured. The maximum expected annual dose to the extremities appeared to be less than the annual limit (500 mSv/y) because all of these workers are on rotation and do not constantly handle radioactivity throughout the year

  1. Maintaining occupational dose ALARA through work management

    International Nuclear Information System (INIS)

    Khan, A. H.

    1999-01-01

    Canadian philosophy in keeping occupational dose ALARA has been to train staff in radiation safety so that they can be fully responsible for participating in minimizing the risks associated with the hazardous work. Senior managers actively promote high standards of performance in dose reduction techniques as a means for integrating ALARA into the operation and maintenance of the station by all personnel. Minimizing radiation dose is accomplished by applying cost effective work management techniques such as Job Safety Analysis, pre-job briefings and establishing and achieving radiation dose goals. Radiation dose goals are used as a management tool for involving all work groups in reducing doses as well as providing a means of assessing the effectiveness of dose reduction actions. ALARA, along with conventional safety, is used as a lever to raise the standard of quality of work and to overall build a safety culture. (author). 4 figs

  2. Radioactivity levels of 238U and 232Th, the α and β activities and associated dose rates from surface soil in Ulu Tiram, Malaysia

    International Nuclear Information System (INIS)

    Abdul Rahman, A.T.; Ramli, A.T.

    2007-01-01

    A survey was carried out to determine terrestrial gamma radiation dose rates, the concentration level of 238 U and 232 Th and α and β activities for the surface soil in Ulu Tiram, Malaysia. A 125 measurements were performed using a NaI(Tl) gamma-ray detector with crystal size of 1' x 1' on 15 soil samples collected from the site area about 102 km 2 . 238 U and 232 Th concentrations were determined in soils by using hyper pure germanium (HPGe) gamma-ray spectrometry. The activity of α and β from the surface soil was counted by using alpha beta counting system. The average value of 238 U and 232 Th concentrations in soil samples collected are 3.63±0.39 ppm within the range of 1.74±0.20 to 4.58±0.48 and 43.00±2.31 ppm within the range of 10.68±0.76 to 82.10±4.01 ppm, respectively. The average estimate of α and β activity in soil samples collected are 0.65±0.09 Bq x g -1 and 0.68±0.08 Bq x g -1 , respectively. The average of terrestrial gamma-radiation dose rates measured in Ulu Tiram was found to be 200 nGy x h -1 , within the range of 96 to 409 nGy x h -1 . The population weighted outdoor annual effective dose was 1.2 mSv. (author)

  3. External dose-rate conversion factors of radionuclides for air submersion, ground surface contamination and water immersion based on the new ICRP dosimetric setting.

    Science.gov (United States)

    Yoo, Song Jae; Jang, Han-Ki; Lee, Jai-Ki; Noh, Siwan; Cho, Gyuseong

    2013-01-01

    For the assessment of external doses due to contaminated environment, the dose-rate conversion factors (DCFs) prescribed in Federal Guidance Report 12 (FGR 12) and FGR 13 have been widely used. Recently, there were significant changes in dosimetric models and parameters, which include the use of the Reference Male and Female Phantoms and the revised tissue weighting factors, as well as the updated decay data of radionuclides. In this study, the DCFs for effective and equivalent doses were calculated for three exposure settings: skyshine, groundshine and water immersion. Doses to the Reference Phantoms were calculated by Monte Carlo simulations with the MCNPX 2.7.0 radiation transport code for 26 mono-energy photons between 0.01 and 10 MeV. The transport calculations were performed for the source volume within the cut-off distances practically contributing to the dose rates, which were determined by a simplified calculation model. For small tissues for which the reduction of variances are difficult, the equivalent dose ratios to a larger tissue (with lower statistical errors) nearby were employed to make the calculation efficient. Empirical response functions relating photon energies, and the organ equivalent doses or the effective doses were then derived by the use of cubic-spline fitting of the resulting doses for 26 energy points. The DCFs for all radionuclides considered important were evaluated by combining the photon emission data of the radionuclide and the empirical response functions. Finally, contributions of accompanied beta particles to the skin equivalent doses and the effective doses were calculated separately and added to the DCFs. For radionuclides considered in this study, the new DCFs for the three exposure settings were within ±10 % when compared with DCFs in FGR 13.

  4. MONTEC, an interactive fortran program to simulate radiation dose and dose-rate responses of populations

    International Nuclear Information System (INIS)

    Perry, K.A.; Szekely, J.G.

    1983-09-01

    The computer program MONTEC was written to simulate the distribution of responses in a population whose members are exposed to multiple radiation doses at variable dose rates. These doses and dose rates are randomly selected from lognormal distributions. The individual radiation responses are calculated from three equations, which include dose and dose-rate terms. Other response-dose/rate relationships or distributions can be incorporated by the user as the need arises. The purpose of this documentation is to provide a complete operating manual for the program. This version is written in FORTRAN-10 for the DEC system PDP-10

  5. Experimental data and dose-response models

    International Nuclear Information System (INIS)

    Ullrich, R.L.

    1985-01-01

    Dose-response relationships for radiation carcinogenesis have been of interest to biologists, modelers, and statisticians for many years. Despite his interest there are few instances in which there are sufficient experimental data to allow the fitting of various dose-response models. In those experimental systems for which data are available the dose-response curves for tumor induction for the various systems cannot be described by a single model. Dose-response models which have been observed following acute exposures to gamma rays include threshold, quadratic, and linear models. Data on sex, age, and environmental influences of dose suggest a strong role of host factors on the dose response. With decreasing dose rate the effectiveness of gamma ray irradiation tends to decrease in essentially every instance. In those cases in which the high dose rate dose response could be described by a quadratic model, the effect of dose rate is consistent with predictions based on radiation effects on the induction of initial events. Whether the underlying reasons for the observed dose-rate effect is a result of effects on the induction of initial events or is due to effects on the subsequent steps in the carcinogenic process is unknown. Information on the dose response for tumor induction for high LET (linear energy transfer) radiations such as neutrons is even more limited. The observed dose and dose rate data for tumor induction following neutron exposure are complex and do not appear to be consistent with predictions based on models for the induction of initial events

  6. Patient Dose From Megavoltage Computed Tomography Imaging

    International Nuclear Information System (INIS)

    Shah, Amish P.; Langen, Katja M.; Ruchala, Kenneth J.; Cox, Andrea; Kupelian, Patrick A.; Meeks, Sanford L.

    2008-01-01

    Purpose: Megavoltage computed tomography (MVCT) can be used daily for imaging with a helical tomotherapy unit for patient alignment before treatment delivery. The purpose of this investigation was to show that the MVCT dose can be computed in phantoms, and further, that the dose can be reported for actual patients from MVCT on a helical tomotherapy unit. Methods and Materials: An MVCT beam model was commissioned and verified through a series of absorbed dose measurements in phantoms. This model was then used to retrospectively calculate the imaging doses to the patients. The MVCT dose was computed for five clinical cases: prostate, breast, head/neck, lung, and craniospinal axis. Results: Validation measurements in phantoms verified that the computed dose can be reported to within 5% of the measured dose delivered at the helical tomotherapy unit. The imaging dose scaled inversely with changes to the CT pitch. Relative to a normal pitch of 2.0, the organ dose can be scaled by 0.67 and 2.0 for scans done with a pitch of 3.0 and 1.0, respectively. Typical doses were in the range of 1.0-2.0 cGy, if imaged with a normal pitch. The maximal organ dose calculated was 3.6 cGy in the neck region of the craniospinal patient, if imaged with a pitch of 1.0. Conclusion: Calculation of the MVCT dose has shown that the typical imaging dose is approximately 1.5 cGy per image. The uniform MVCT dose delivered using helical tomotherapy is greatest when the anatomic thickness is the smallest and the pitch is set to the lowest value

  7. Conventional radiology and genetic dose

    International Nuclear Information System (INIS)

    Gonzalez-Vila, V.; Fernandez, A.; Rivera, F.; Martinez, M.; Gomez, A.; Luis, J.

    1992-01-01

    A research project was established in 1984 to evaluate the expected genetic abnormalities due to radiation received by the population attending the Outpatient Radiological Service due to medical radiological practices. The study was conducted in 1985 (12 weeks chosen by random). The equivalent gonadal dose was the chosen parameter, representing the social cost of the radiology. Samples of 2945 men and 2929 women were considered in the study. The number of genetic abnormalities, in relation to the mean age of reproduction (a generation every 30 years), was 2.13 cases per million in the first generation and 15.97 cases per million at equilibrium. The authors interpretation is that both the method and the expected genetic detriment are suitable procedures for the characterisation of the Radiological Service as a radiation source. (author)

  8. Quality control for dose calibrators

    International Nuclear Information System (INIS)

    Mendes, L.C.G.

    1984-01-01

    Nuclear medicine laboratories are required to assay samples of radioactivity to be administered to patients. Almost universally, these assays are accomplished by use of a well ionization chamber isotope calibrator. The Instituto de Radioprotecao e Dosimetria (Institute for Radiological Protection and Dosimetry) of the Comissao Nacional de Energia Nuclear (National Commission for Nuclear Energy) is carrying out a National Quality Control Programme in Nuclear Medicine, supported by the International Atomic Energy Agency. The assessment of the current needs and practices of quality control in the entire country of Brazil includes Dose Calibrators and Scintillation Cameras, but this manual is restricted to the former. Quality Control Procedures for these Instruments are described in this document together with specific recommendations and assessment of its accuracy. (author)

  9. Method of preparing radionuclide doses

    International Nuclear Information System (INIS)

    Kuperus, J.H.

    1987-01-01

    A method is described of preparing aliquot dosea of a tracer material useful in diagnostic nuclear medicine comprising: storing discrete quantities of a lyophilized radionuclide carrier in separate tubular containers from which air and moisture is excluded, selecting from the tubular containers a container in which is stored a carrier appropriate for a nuclear diagnostic test to be performed, interposing the selected container between the needle and the barrel of a hypodermic syringe, and drawing a predetermined amount of a liquid containing a radionuclide tracer in known concentration into the hypodermic syringe barrel through the hypodermic needle and through the selected container to dissolve the discrete quantity of lyophilized carrier therein to combine the carrier with the radionuclide tracer to form an aliquot dose of nuclear diagnostic tracer material, as needed

  10. Optimizing lithium dosing in hemodialysis

    DEFF Research Database (Denmark)

    Bjarnason, N H; Munkner, R; Kampmann, J P

    2006-01-01

    We studied a 62-year-old female hemodialysis patient during initiation and maintenance of lithium carbonate therapy. Three different methods were applied to estimate the regimen: a scenario based on volume of distribution (V(d)), a scenario based on glomerular filtration rate (GFR), and a scenario...... estimates. Furthermore, the maintenance dose estimated from the central compartment (V1) led to plasma concentrations within the therapeutic range. Thus, a regimen where 12.2 mmol lithium was given after each hemodialysis session resulted in stable between-dialysis plasma lithium concentrations...... in this patient with no residual kidney function. We did not observe adverse effects related to this regimen, which was monitored from 18 days to 8 months of therapy, and the patient experienced relief from her severe depressive disorder. In conclusion, dialysis patients may be treated with lithium administrated...

  11. Dose estimation for paediatric cranial computed tomography

    International Nuclear Information System (INIS)

    Curci Daros, K.A.; Bitelli Medeiros, R.; Curci Daros, K.A.; Oliveira Echeimberg, J. de

    2006-01-01

    In the last ten years, the number of paediatric computed tomography (CT) scans have increased worldwide, contributing to higher population radiation dose. Technique diversification in paediatrics and different CT equipment technologies have led to various exposure levels complicating precise evaluation of doses and operational conditions necessary for good quality images. The objective of this study was to establish a quantitative relationship between absorbed dose and cranial region in children up to 6 years old undergoing CT exams. Methods: X-ray was measured on the cranial surface of 64 patients undergoing CT using thermoluminescent (T.L.) dosimeters. Forty T.L.D.100 thermoluminescent dosimeters (T.L.D.) were evenly distributed on each patients skin surface along the sagittal axis. Measurements were performed in facial regions exposed to scatter radiation and in the supratentorial and posterior fossa regions, submitted to primary radiation. T.L.D. were calibrated for 120 kV X-ray over the acrylic phantom. T.L. measurements were made with a Harshaw 4000 system. Patient mean T.L. readings were determined for position, pi, of T.L.D. and normalized to the maximum supratentorial reading. From integrating the linear T.L. density function (?) resulting from radiation distribution in each of the three exposed regions, dose fraction was determined in the region of interest, along with total dose under the technical conditions used in that specific exam protocol. For each T.L.D. position along the patient cranium, there were n T.L. measurements with 2% uncertainty due to T.L. reader, and 5% due to thermal treatment of dosimeters. Also, mean T.L. readings and their uncertainties were calculated for each patient at each position, p. Results: Mean linear T.L. density for the region exposed to secondary radiation defined by position, 0.3≤p≤6 cm, was ρ((p)=7.9(4)x10 -2 +7(5)x10 -5 p 4.5(4) cm -1 ; exposed to primary X-ray for the posterior fossa region defined by position

  12. Dose estimation for paediatric cranial computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Curci Daros, K.A.; Bitelli Medeiros, R. [Sao Paulo Univ. Federal (Brazil); Curci Daros, K.A.; Oliveira Echeimberg, J. de [Centro Univ. Sao Camilo, Sao Paulo (Brazil)

    2006-07-01

    In the last ten years, the number of paediatric computed tomography (CT) scans have increased worldwide, contributing to higher population radiation dose. Technique diversification in paediatrics and different CT equipment technologies have led to various exposure levels complicating precise evaluation of doses and operational conditions necessary for good quality images. The objective of this study was to establish a quantitative relationship between absorbed dose and cranial region in children up to 6 years old undergoing CT exams. Methods: X-ray was measured on the cranial surface of 64 patients undergoing CT using thermoluminescent (T.L.) dosimeters. Forty T.L.D.100 thermoluminescent dosimeters (T.L.D.) were evenly distributed on each patients skin surface along the sagittal axis. Measurements were performed in facial regions exposed to scatter radiation and in the supratentorial and posterior fossa regions, submitted to primary radiation. T.L.D. were calibrated for 120 kV X-ray over the acrylic phantom. T.L. measurements were made with a Harshaw 4000 system. Patient mean T.L. readings were determined for position, pi, of T.L.D. and normalized to the maximum supratentorial reading. From integrating the linear T.L. density function (?) resulting from radiation distribution in each of the three exposed regions, dose fraction was determined in the region of interest, along with total dose under the technical conditions used in that specific exam protocol. For each T.L.D. position along the patient cranium, there were n T.L. measurements with 2% uncertainty due to T.L. reader, and 5% due to thermal treatment of dosimeters. Also, mean T.L. readings and their uncertainties were calculated for each patient at each position, p. Results: Mean linear T.L. density for the region exposed to secondary radiation defined by position, 0.3{<=}p{<=}6 cm, was {rho}((p)=7.9(4)x10{sup -2}+7(5)x10{sup -5}p{sup 4.5(4)} cm{sup -1}; exposed to primary X-ray for the posterior fossa

  13. Determination of Entrance Skin Doses and Organ Doses for Medical X Ray Examinations

    International Nuclear Information System (INIS)

    Tung, C.J.; Cheng, C.Y.; Chao, T.C.; Tsai, H.Y.

    1999-01-01

    A national survey of patient doses for diagnostic X ray radiographs is planned in Taiwan. Entrance skin doses and organ doses for all installed X ray machines will be investigated. A pilot study has been carried out for the national survey to develop a protocol for the dose assessment. Entrance skin doses and organ doses were measured by thermoluminescence dosemeters and calculated by Monte Carlo simulations for several X ray examinations. The conversion factor from free air entrance absorbed dose to entrance skin dose was derived. A formula for the computation of entrance skin doses from inputs of kV p , mA.s, source to skin distance, aluminium filtration, and generator rectifying was constructed. Organ doses were measured using a RANDO phantom and calculated using a mathematical phantom. All data will be passed to the Atomic Energy Council for developing a programme of national survey and regulatory controls for diagnostic X ray examinations. (author)

  14. Dose-shaping using targeted sparse optimization

    Energy Technology Data Exchange (ETDEWEB)

    Sayre, George A.; Ruan, Dan [Department of Radiation Oncology, University of California - Los Angeles School of Medicine, 200 Medical Plaza, Los Angeles, California 90095 (United States)

    2013-07-15

    }{sup sparse} improves tradeoff between planning goals by 'sacrificing' voxels that have already been violated to improve PTV coverage, PTV homogeneity, and/or OAR-sparing. In doing so, overall plan quality is increased since these large violations only arise if a net reduction in E{sub tot}{sup sparse} occurs as a result. For example, large violations to dose prescription in the PTV in E{sub tot}{sup sparse}-optimized plans will naturally localize to voxels in and around PTV-OAR overlaps where OAR-sparing may be increased without compromising target coverage. The authors compared the results of our method and the corresponding clinical plans using analyses of DVH plots, dose maps, and two quantitative metrics that quantify PTV homogeneity and overdose. These metrics do not penalize underdose since E{sub tot}{sup sparse}-optimized plans were planned such that their target coverage was similar or better than that of the clinical plans. Finally, plan deliverability was assessed with the 2D modulation index.Results: The proposed method was implemented using IBM's CPLEX optimization package (ILOG CPLEX, Sunnyvale, CA) and required 1-4 min to solve with a 12-core Intel i7 processor. In the testing procedure, the authors optimized for several points on the Pareto surface of four 7-field 6MV prostate cases that were optimized for different levels of PTV homogeneity and OAR-sparing. The generated results were compared against each other and the clinical plan by analyzing their DVH plots and dose maps. After developing intuition by planning the four prostate cases, which had relatively few tradeoffs, the authors applied our method to a 7-field 6 MV pancreas case and a 9-field 6MV head-and-neck case to test the potential impact of our method on more challenging cases. The authors found that our formulation: (1) provided excellent flexibility for balancing OAR-sparing with PTV homogeneity; and (2) permitted the dose planner more control over the evolution of the PTV

  15. Dose-shaping using targeted sparse optimization

    International Nuclear Information System (INIS)

    Sayre, George A.; Ruan, Dan

    2013-01-01

    tradeoff between planning goals by “sacrificing” voxels that have already been violated to improve PTV coverage, PTV homogeneity, and/or OAR-sparing. In doing so, overall plan quality is increased since these large violations only arise if a net reduction in E tot sparse occurs as a result. For example, large violations to dose prescription in the PTV in E tot sparse -optimized plans will naturally localize to voxels in and around PTV-OAR overlaps where OAR-sparing may be increased without compromising target coverage. The authors compared the results of our method and the corresponding clinical plans using analyses of DVH plots, dose maps, and two quantitative metrics that quantify PTV homogeneity and overdose. These metrics do not penalize underdose since E tot sparse -optimized plans were planned such that their target coverage was similar or better than that of the clinical plans. Finally, plan deliverability was assessed with the 2D modulation index.Results: The proposed method was implemented using IBM's CPLEX optimization package (ILOG CPLEX, Sunnyvale, CA) and required 1–4 min to solve with a 12-core Intel i7 processor. In the testing procedure, the authors optimized for several points on the Pareto surface of four 7-field 6MV prostate cases that were optimized for different levels of PTV homogeneity and OAR-sparing. The generated results were compared against each other and the clinical plan by analyzing their DVH plots and dose maps. After developing intuition by planning the four prostate cases, which had relatively few tradeoffs, the authors applied our method to a 7-field 6 MV pancreas case and a 9-field 6MV head-and-neck case to test the potential impact of our method on more challenging cases. The authors found that our formulation: (1) provided excellent flexibility for balancing OAR-sparing with PTV homogeneity; and (2) permitted the dose planner more control over the evolution of the PTV's spatial dose distribution than conventional objective

  16. Dose-shaping using targeted sparse optimization.

    Science.gov (United States)

    Sayre, George A; Ruan, Dan

    2013-07-01

    planning goals by "sacrificing" voxels that have already been violated to improve PTV coverage, PTV homogeneity, and/or OAR-sparing. In doing so, overall plan quality is increased since these large violations only arise if a net reduction in E tot (sparse) occurs as a result. For example, large violations to dose prescription in the PTV in E tot (sparse)-optimized plans will naturally localize to voxels in and around PTV-OAR overlaps where OAR-sparing may be increased without compromising target coverage. The authors compared the results of our method and the corresponding clinical plans using analyses of DVH plots, dose maps, and two quantitative metrics that quantify PTV homogeneity and overdose. These metrics do not penalize underdose since Etot (sparse)-optimized plans were planned such that their target coverage was similar or better than that of the clinical plans. Finally, plan deliverability was assessed with the 2D modulation index. The proposed method was implemented using IBM's CPLEX optimization package (ILOG CPLEX, Sunnyvale, CA) and required 1-4 min to solve with a 12-core Intel i7 processor. In the testing procedure, the authors optimized for several points on the Pareto surface of four 7-field 6MV prostate cases that were optimized for different levels of PTV homogeneity and OAR-sparing. The generated results were compared against each other and the clinical plan by analyzing their DVH