WorldWideScience

Sample records for surface contamination tap

  1. Contamination Control and Monitoring of Tap Water as Fluid in Industrial Tap Water Hydraulic Systems

    DEFF Research Database (Denmark)

    Conrad, Finn; Adelstorp, Anders

    1998-01-01

    Presentation of results and methods addressed to contamination control and monitoring of tap water as fluid in tap water hydraulic systems.......Presentation of results and methods addressed to contamination control and monitoring of tap water as fluid in tap water hydraulic systems....

  2. Oropharyngeal Tularemia Outbreak Associated with Drinking Contaminated Tap Water, Turkey, July-September 2013.

    Science.gov (United States)

    Aktas, Dilber; Celebi, Bekir; Isik, Mehmet Emirhan; Tutus, Celal; Ozturk, Huseyin; Temel, Fehminaz; Kizilaslan, Mecit; Zhu, Bao-Ping

    2015-12-01

    In 2013, an oropharyngeal tularemia outbreak in Turkey affected 55 persons. Drinking tap water during the likely exposure period was significantly associated with illness (attack rate 27% vs. 11% among non-tap water drinkers). Findings showed the tap water source had been contaminated by surface water, and the chlorination device malfunctioned.

  3. Radioactive surface contamination monitors

    International Nuclear Information System (INIS)

    Aoyama, Kei; Minagoshi, Atsushi; Hasegawa, Toru

    1994-01-01

    To reduce radiation exposure and prevent contamination from spreading, each nuclear power plant has established a radiation controlled area. People and articles out of the controlled area are checked for the surface contamination of radioactive materials with surface contamination monitors. Fuji Electric has repeatedly improved these monitors on the basis of user's needs. This paper outlines typical of a surface contamination monitor, a personal surface contamination monitor, an article surface contamination monitor and a laundry monitor, and the whole-body counter of an internal contamination monitor. (author)

  4. Existence of Insecticides in Tap Drinking Surface and Ground Water in Dakahlyia Governorate, Egypt in 2011

    Directory of Open Access Journals (Sweden)

    RA Mandour

    2011-12-01

    Full Text Available Background: The environmental degradation products of pesticides may enter drinking water and result in serious health problems. Objective: To evaluate the occurrence of insecticides in drinking surface and ground water in Dakahlyia Governorate, northern Egypt in 2011. Methods: We studied blood samples collected from 36 consecutive patients diagnosed with pesticides poisoning and 36 tap drinking water (surface and ground. Blood and water samples were analyzed for pesticides using gas chromatography-electron captured detector (GC-ECD. In addition, blood samples were analyzed for plasma pseudo-cholinesterase level (PChE and red blood cells acetyl cholinesterase activity (AChE. Results: The results confirmed the presence of high concentrations of insecticides, including organonitrogenous and organochlorine in tap drinking surface and ground water. Conclusion: Drinking water contaminated with insecticides constitutes an important health concern in Dakahlyia governorate, Egypt.

  5. Surface soil contamination standards

    International Nuclear Information System (INIS)

    Boothe, G.F.

    1979-01-01

    The purpose of this document is to define surface soil contamination limits for radioactive materials below which posting, restrictions and environmental controls are not necessary in order to protect personnel and the environment. The standards can also be used to determine if solid waste or other material is contaminated relative to disposal requirements. The derivation of the standards is given

  6. Tapping of Love waves in an isotropic surface waveguide by surface-to-bulk wave transduction.

    Science.gov (United States)

    Tuan, H.-S.; Chang, C.-P.

    1972-01-01

    A theoretical study of tapping a Love wave in an isotropic microacoustic surface waveguide is given. The surface Love wave is tapped by partial transduction into a bulk wave at a discontinuity. It is shown that, by careful design of the discontinuity, the converted bulk wave power and the radiation pattern may be controlled. General formulas are derived for the calculation of these important characteristics from a relatively general surface contour deformation.

  7. Fluorescence Imaging Reveals Surface Contamination

    Science.gov (United States)

    Schirato, Richard; Polichar, Raulf

    1992-01-01

    In technique to detect surface contamination, object inspected illuminated by ultraviolet light to make contaminants fluoresce; low-light-level video camera views fluorescence. Image-processing techniques quantify distribution of contaminants. If fluorescence of material expected to contaminate surface is not intense, tagged with low concentration of dye.

  8. Spatial and statistical methods for correlating the interaction between groundwater contamination and tap water exposure in karst regions

    Science.gov (United States)

    Padilla, I. Y.; Rivera, V. L.; Macchiavelli, R. E.; Torres Torres, N. I.

    2016-12-01

    Groundwater systems in karst regions are highly vulnerable to contamination and have an enormous capacity to store and rapidly convey pollutants to potential exposure zones over long periods of time. Contaminants in karst aquifers used for drinking water purposes can, therefore, enter distributions lines and the tap water point of use. This study applies spatial and statistical analytical methods to assess potential correlations between contaminants in a karst groundwater system in northern Puerto Rico and exposure in the tap water. It focuses on chlorinated volatile organic compounds (CVOC) and phthalates because of their ubiquitous presence in the environment and the potential public health impacts. The work integrates historical data collected from regulatory agencies and current field measurements involving groundwater and tap water sampling and analysis. Contaminant distributions and cluster analysis is performed with Geographic Information System technology. Correlations between detection frequencies and contaminants concentration in source groundwater and tap water point of use are assessed using Pearson's Chi Square and T-Test analysis. Although results indicate that correlations are contaminant-specific, detection frequencies are generally higher for total CVOC in groundwater than tap water samples, but greater for phthalates in tap water than groundwater samples. Spatial analysis shows widespread distribution of CVOC and phthalates in both groundwater and tap water, suggesting that contamination comes from multiple sources. Spatial correlation analysis indicates that association between tap water and groundwater contamination depends on the source and type of contaminants, spatial location, and time. Full description of the correlations may, however, need to take into consideration variable anthropogenic interventions.

  9. Control of bacterial contamination of washbasin taps and output water using Ecasol: a one-year study.

    LENUS (Irish Health Repository)

    Boyle, M A

    2012-04-01

    Contaminated washbasin taps and output water are an important source of bacteria that may cause nosocomial infection. A five-week pretreatment study of hot and cold water from 15 washbasin taps at Dublin Dental Hospital showed consistently heavy contamination by aerobic heterotrophic bacteria: mean bacterial counts of 482.5 [standard deviation (SD) 293] colony-forming units (cfu)\\/mL and 5022 (SD 4322) cfu\\/mL, respectively.

  10. Residential tap water contamination following the Freedom Industries chemical spill: perceptions, water quality, and health impacts.

    Science.gov (United States)

    Whelton, Andrew J; McMillan, LaKia; Connell, Matt; Kelley, Keven M; Gill, Jeff P; White, Kevin D; Gupta, Rahul; Dey, Rajarshi; Novy, Caroline

    2015-01-20

    During January 2014, an industrial solvent contaminated West Virginia’s Elk River and 15% of the state population’s tap water. A rapid in-home survey and water testing was conducted 2 weeks following the spill to understand resident perceptions, tap water chemical levels, and premise plumbing flushing effectiveness. Water odors were detected in all 10 homes sampled before and after premise plumbing flushing. Survey and medical data indicated flushing caused adverse health impacts. Bench-scale experiments and physiochemical property predictions showed flushing promoted chemical volatilization, and contaminants did not appreciably sorb into cross-linked polyethylene (PEX) pipe. Flushing reduced tap water 4-methylcyclohexanemethanol (4-MCHM) concentrations within some but not all homes. 4-MCHM was detected at unflushed (waters contained less 4-MCHM than the 1000 μg/L Centers for Disease Control drinking water limit, but one home exceeded the 120 μg/L drinking water limit established by independent toxicologists. Nearly all households refused to resume water use activities after flushing because of water safety concerns. Science based flushing protocols should be developed to expedite recovery, minimize health impacts, and reduce concentrations in homes when future events occur.

  11. Assessment of the Extraction Methods for Monitoring Phthalate Emerging Contaminants in Groundwater and Tap Water

    Science.gov (United States)

    Cotto, I.; Padilla, I. Y.; De Jesús, N. H.; Torres, P. M.

    2015-12-01

    Trace organic contaminants such as phthalates, among other chemicals of emerging concerns, have not historically been considered as pollutants but are being detected in water, posing a potential risk to public health and the environment. One of the most common phthalates of particular concern is di-(2-ethylhexyl) phthalate (DEHP), a plasticizer normally found in plastics and consumer products, including: cosmetics, pharmaceuticals, medical devices, food packages, water bottles, and wiring cables. DEHP has been associated with preterm birth, a major cause of neonatal mortality and health complications. This study aims at monitoring the presence and concentration of DEHP and other phthalates in groundwater and tap water systems in Puerto Rico, which has one of the highest rates of preterm birth in the U.S. The Environmental Protection Agency (EPA) suggests a liquid-liquid extraction method that uses methylene chloride as the preferred organic solvent for the extractions. This work presents modified EPA methods that reduce the volume of sample and solvent used, lower the time of analysis, increase productivity, and decrease hazards and waste. Distribution coefficient of DEHP between methylene chloride and water are estimated and related to sample extraction efficiency. Research results indicate that DEHP is in fact distributed between water and methylene chloride with a distribution coefficient average value of 1.24. The study concludes that the sample and solvent volumes have influence on the efficiency but have not an effect on the distribution coefficient. The tests show higher extraction efficiencies for lower DEHP concentrations and higher extraction volumes. Results from the water analysis show presence of DEHP in 55% of groundwater and 44% of tap water samples, indicating a potential exposure through water.

  12. Biofilm formation in an experimental water distribution system: the contamination of non-touch sensor taps and the implication for healthcare.

    Science.gov (United States)

    Moore, Ginny; Stevenson, David; Thompson, Katy-Anne; Parks, Simon; Ngabo, Didier; Bennett, Allan M; Walker, Jimmy T

    2015-01-01

    Hospital tap water is a recognised source of Pseudomonas aeruginosa. U.K. guidance documents recommend measures to control/minimise the risk of P. aeruginosa in augmented care units but these are based on limited scientific evidence. An experimental water distribution system was designed to investigate colonisation of hospital tap components. P. aeruginosa was injected into 27 individual tap 'assemblies'. Taps were subsequently flushed twice daily and contamination levels monitored over two years. Tap assemblies were systematically dismantled and assessed microbiologically and the effect of removing potentially contaminated components was determined. P. aeruginosa was repeatedly recovered from the tap water at levels above the augmented care alert level. The organism was recovered from all dismantled solenoid valves with colonisation of the ethylene propylene diene monomer (EPDM) diaphragm confirmed by microscopy. Removing the solenoid valves reduced P. aeruginosa counts in the water to below detectable levels. This effect was immediate and sustained, implicating the solenoid diaphragm as the primary contamination source.

  13. Contamination of Tap Water with Pseudomonas aeruginosa, Legionella pneumophila, and Escherichia coli in Guilan, Iran

    Directory of Open Access Journals (Sweden)

    Masoumeh Ahmadi Jalali Moghadam

    2016-12-01

    Full Text Available Background: River and underground waters are main sources of tap water in Guilan, Iran. Overlandwastes move into rivers during periods of heavy or extended rain that is very common in the area.Pseudomonas aeruginosa, Legionella pneumophila, and Escherichia coli are main human pathogenswith water source. This study is designed to determine the load of these bacteria in main water suppliesof the area.Methods: Samples were collected directly into sterile containers, concentrated by centrifuge,inoculated in enrichment medium and incubated for 3-4 days. DNA was extracted by using commercialkit. Several rounds of PCR was performed to search P. aeroginosa, integron I, Metallo-β-lactamasesgene, L. pneumophila, mip gene, and E. coli.Results: About 92.0% of the samples showed bacterial contamination as revealed by PCR with primersof 16S rRNAgene, 9.5% of the samples had L. pneumophila, and 11,1% had Pseudomonas aeruginosa,but Escherichia coli was not detected. We found the mip gene in 66.6% of the samples with L.pneumophila. Metallo-β-lactamasesgene was found in 11.1% of all samples. We also found Integrin 1in 28.5% of the samples with P. aeruginosa.Conclusion: This study indicates that in spite of chlorination, total bacterial contamination of potwaters in the area is high and contamination with L. pneumophila and P. aeroginosa is considerable. Itmight be related to the biofilm formation and the growth of water microflora. It seems that free residualchlorine is ineffective. We suggest a more effective decontamination procedure based on moderntechnology.

  14. Contamination of hospital tap water: the survival and persistence of Pseudomonas aeruginosa on conventional and 'antimicrobial' outlet fittings.

    Science.gov (United States)

    Hutchins, C F; Moore, G; Thompson, K-A; Webb, J; Walker, J T

    2017-10-01

    Pseudomonas aeruginosa infections have been linked to contaminated hospital taps, highlighting the potential for tap outlet fittings (OF) to harbour biofilm. P. aeruginosa may be transferred to OFs via contaminated cleaning cloths. Suggested interventions include flushing regimens and alternative OF designs. To investigate the transfer of P. aeruginosa from a contaminated cleaning cloth to conventional and 'antimicrobial/antibiofilm' OFs and to determine whether this contamination persists and/or leads to contamination of tap water. Microfibre cloths contaminated with P. aeruginosa (10 8  cfu/mL) were used to wipe four different types of OF [one of conventional design (OF-A) and three marketed as 'antimicrobial' and/or 'antibiofilm' (OF- B, -C and -D)]. OFs were inserted into an experimental water distribution system for up to 24 h. Survival was assessed by culture. Single and multiple water samples were collected and cultured for P. aeruginosa. The median number of P. aeruginosa transferred from cloth to OF was 5.7 × 10 5  cfu (OF-A), 1.9 × 10 6  cfu (OF-B), 1.4 × 10 5  cfu (OF-C) and 2.9 × 10 6  cfu (OF-D). Numbers declined on all OFs during the 24 h period with log reductions ranging from 3.5 (OF-C) to 5.2 (OF-B; P > 0.05). All water samples delivered immediately after OF contamination contained P. aeruginosa at ≥10 cfu per 100 mL. Contamination of water delivered from OF-A persisted despite continued flushing. Water delivered from OF-B did not contain P. aeruginosa beyond the first flush. Contaminated cleaning cloths may transfer P. aeruginosa to OFs, leading to contamination of tap water. Although not removing the potential for contamination, 'antimicrobial/antibiofilm' OFs may prevent P. aeruginosa from continually contaminating water delivered from the outlet. Copyright © 2017 The Healthcare Infection Society. All rights reserved.

  15. Redispersion of indoor surface contamination: a review

    International Nuclear Information System (INIS)

    Sansone, E.B.; Slein, M.W.

    1978-01-01

    The importance of surface contamination as a potential source of exposure to hazardous materials is discussed. Data from the literature concerning the resuspension of indoor surface contamination are presented. Reported procedures for quantitating surface contamination are compared. It is suggested that, despite its limitations, surface contamination monitoring may be useful in estimating potential risks from hazardous materials. (Auth.)

  16. Optical measurements on contaminated surfaces

    Science.gov (United States)

    Bonham, T. E.; Schmitt, R. J.; Linford, R. M. F.

    1975-01-01

    A bidirectional reflectometer system was developed for in situ measurements of the changes in spectral reflectance of surfaces contaminated with films of organic materials. The system permits experiments with films of controlled thickness in an environment that simulates the thermal, radiation, and vacuum conditions of space. The mechanical and optical construction of the reflectometer are discussed in detail, and actual data curves are used to illustrate its operation and performance.

  17. Hydrogen Contamination of Niobium Surfaces

    International Nuclear Information System (INIS)

    Viet Nguyen-Tuong; Lawrence Doolittle

    1993-01-01

    The presence of hydrogen is blamed for dramatic reductions in cavity Q's. Hydrogen concentration is difficult to measure, so there is a great deal of Fear, Uncertainty, and Doubt (FUD) associated with the problem. This paper presents measurements of hydrogen concentration depth profiles, commenting on the pitfalls of the methods used and exploring how material handling can change the amount of hydrogen in pieces of niobium. Hydrogen analysis was performed by a forward scattering experiment with Helium used as the primary beam. This technique is variously known as FRES (Forward Recoil Elastic Scattering), FRS, HFS (Hydrogen Forward Scattering), and HRA (Hydrogen Recoil Analysis). Some measurements were also made using SIMS (Secondary Ion Mass Spectrometry). Both HFS and SIMS are capable of measuring a depth profile of Hydrogen. The primary difficulty in interpreting the results from these techniques is the presence of a surface peak which is due (at least in part) to contamination with either water or hydrocarbons. With HFS, the depth resolution is about 30 nm, and the maximum depth profiled is about 300 nm. (This 10-1 ratio is unusually low for ion beam techniques, and is a consequence of the compromises that must be made in the geometry of the experiment, surface roughness, and energy straggling in the absorber foil that must be used to filter out the forward scattered helium.) All the observed HFS spectra include a surface peak which includes both surface contamination and any real hydrogen uptake by the niobium surface. Some contamination occurs during the analysis. The vacuum in the analysis chamber is typically a few times 10(sup -6) torr, and some of the contamination is in the form of hydrocarbons from the pumping system. Hydrocarbons normally form a very thin (less than a monolayer) film which is in equilibrium between arrival rate and the evaporation rate. In the presence of the incoming ion beam, however, these hydrocarbons crack on the surface into non

  18. Some problems in calibrating surface contamination meters

    International Nuclear Information System (INIS)

    Chen Zigen; LI Xingyuan; Shuai Xiaoping.

    1984-01-01

    It is necessary that instruments are calibrated accurately in order to obtain reliable survey data of surface contamination. Some problems in calibrating surface contamination meters are expounded in this paper. Measurement comparison for beta surface contamination meters is organized within limited scope, thus survey quality is understood, questions are discovered, significance of calibration is expounded further. (Author)

  19. Tests of some methods to remove I-131 from contaminated tap water

    International Nuclear Information System (INIS)

    Tagami, Keiko; Uchida, Shigeo

    2011-01-01

    Following the Fukushima Daiichi Nuclear Power Plant accident, iodine-131 concentrations in tap water higher than 100 Bq L"-"1 were reported by several local governments in the Kanto Plain in March 2011. To remove iodine-131 from tap water, five methods were tested in this study, that is, (1) boiling, (2) adding charcoals from oak or bamboo, (3) activated charcoals, (4) water purifiers, and (5) reverse osmosis (RO) treatments. Boiling was shown to be not effective in removing iodine-131 from tap water; indeed even higher concentrations may result from the liquid-volume reduction accompanying this process. Adding charcoals and activated charcoal treatment could not remove iodine-131, because no reduction of iodine-131 was observed in tap water samples after these treatments. Only limited effect was found with water purifiers with first several portions; no effect was expected with further water treatment. On the other hand, the RO showed high iodine-131 removal percentage of more than 95%, although the method needs about 5-10 L water to obtain 1 L of RO treated water. (author)

  20. Derived limits for surface contamination

    CERN Document Server

    Wrixon, A D; Linsley, G S; White, D F

    1979-01-01

    Derived limits (DLs) for surface contamination were first established for use in the nuclear energy industry where a wide variety of radionuclides is encountered. They were later used in factories, hospitals, and universities, where the radionuclides used are normally fewer in number, either known or readily identifiable, and often of low toxicity. In these situations the current limits are frequently over-restrictive. This report describes a reassessment of the values in the light of more recent information on the possible pathways of exposure and the dose equivalent limits given in ICRP Publication 26. The reassessment is prompted also by the introduction of SI units. The results of the reassessment are used to produce a classification of DLs for all radionuclides for active and inactive area surfaces and for skin.

  1. Evaluation of Unfixed Tritium Surface Contamination

    International Nuclear Information System (INIS)

    Postolache, C.; Matei, Lidia

    2005-01-01

    Surface unfixed radioactive contamination represents the amount of surface total radioactive contamination which can be eliminated by pure mechanical processes. This unfixed contamination represents the main risk factor for contamination of the personnel which operates in tritium laboratories. Unfixed contamination was determined using sampling smears type FPCSN-PSE-AA. Those FPCSN-PSE-AA smears are disks of expanded polystyrene which contain acrylic acid fragments superficially grafted. Sampling factor was determinated by contaminated surface wiping with moisten smears in 50 μL butylic alcohol and activity measuring at liquid scintillation measuring device. Sampling factor was determined by the ratio between measured activity and initially real conventional activity. The sampling factor was determined for Tritium Laboratory existent surfaces: stainless steel, aluminum, glass, ceramics, linoleum, washable coats, epoxy resins type ALOREX LP-52.The sampling factors and the reproducibility were determined in function of surface nature

  2. Biodegradation of organ chlorine pesticides in contaminated soil collected from Yen Tap, Cam Khe, Phu Tho

    International Nuclear Information System (INIS)

    Nguyen Thuy Binh; Nguyen Van Toan; Pham Thi Thai; Dinh Thi Thu Hang

    2007-01-01

    Biodegradation of POPs contaminant in soil collected from Phu Tho province and Nghe An province had carried out. The process comprises treating soil, which contains anaerobic and aerobic microbes capable of transforming lindane and DDT into harmless material and being under anaerobic and aerobic steps. Significant biodegradation of POPs contaminants occurred in there tests. But some of toxic organic compounds remained. (author)

  3. Techniques for removing contaminated concrete surfaces

    International Nuclear Information System (INIS)

    Halter, J.M.; Sullivan, R.G.

    1981-01-01

    This discussion compares various techniques that have been used to clean concrete surfaces by removing the surface. Three techniques which have been investigated by the Pacific Northwest Laboratory for removing surfaces are also described: the water cannon, the concrete spaller, and high-pressure water jet. The equipment was developed with the assumption that removal of the top 1/8 to 1/4 in. of surface would remove most of the contamination. If the contamination has gone into cracks or deep voids in the surface, the removal processes can be repeated until the surface is acceptable

  4. BIOREMEDIATION OF CONTAMINATED SURFACE SOILS

    Science.gov (United States)

    Biological remediation of soils contaminated with organic chemicals is an alternative treatment technology that can often meet the goal of achieving a permanent clean-up remedy at hazardous waste sites, as encouraged by the U.S. Environmental Protection Agency (U.S. EPA) for impl...

  5. Calibration of alpha surface contamination monitor

    International Nuclear Information System (INIS)

    Freitas, I.S.M. de; Goncalez, O.L.

    1990-01-01

    In this work, the results, as well as the methodology, of the calibration of an alpha surface contamination monitor are presented. The calibration factors are obtained by least-squares fitting with effective variance. (author)

  6. Surface contamination technology in decommissioning of nuclear fuel cycle

    International Nuclear Information System (INIS)

    Ishiguro, Hideharu

    2012-01-01

    Surface contamination measurement is the most basic technology in radiation control of the nuclear and radiation facilities. Loose surface contamination causes internal exposure through airborne contamination. Surface contamination measurement is recently more important in the waste management such as confirmation of decontamination factor, contamination survey of carried-out materials from radioactive control area, and application of clearance level. This report describes the base of surface contamination standards, meaning of contamination in decommissioning, relationship between clearance level and surface contamination, and current technology of surface contamination measurement. (author)

  7. Monitoring of surface and airborne contamination

    Energy Technology Data Exchange (ETDEWEB)

    Pradeep Kumar, K S [Bhabha Atomic Research Centre, Bombay (India)

    1997-06-01

    Indian nuclear energy programme aims at total safety in all activities involved in the entire fuel cycle for the occupational workers, members of the public and the environment as a whole. Routine radiation monitoring with clearly laid out procedures are followed for ensuring the safety of workers and public. Radiation monitoring carried out for the nuclear installations comprises of process monitoring, monitoring of effluent releases and also of the radiation protection monitoring of the individuals, work place and environment. Regulations like banning of smoking and consumption of food and drink etc. reduces the risk of direct ingestion even if inadvertent spread of contamination takes place. Though limit of transportable surface contamination is prescribed, the health physicists always follow a ``clean on swipe`` philosophy which compensates any error in the measurement of surface contamination. In this paper, the following items are contained: Necessity of contamination monitoring, accuracy required in the calibration of surface contamination monitors, methodology for contamination monitoring, air monitoring, guidelines for unrestricted release of scrap materials, and problems in contamination monitoring. (G.K.)

  8. Decontamination of radioactively contaminated surfaces

    International Nuclear Information System (INIS)

    1986-10-01

    By this standard objective conditions to evaluate and test the ease of decontamination of surfaces under laboratory conditions are to be laid down. Ease of decontamination in this context denotes the summed-up effect of two material properties: a) the capacity of the material for retaining radioactive substances at its surface; b) the ease with which these substances are given off again in the course of cleaning processes. (orig./HP) [de

  9. Development of radioactive surface contamination monitor

    International Nuclear Information System (INIS)

    Hashimoto, Tadao; Hasegawa, Toru; Fukumoto, Keisuke; Ooki, Yasushi

    2008-01-01

    In the radiation facilities such as nuclear power plants, surface contamination of the people accessing or articles conveyed in and out of the radiation controlled areas is detected and monitored by installing contamination monitors at the boundary of controlled areas and uncontrolled areas against the expansion of the radioactive materials to out of the facilities. It is required for the surface contamination of articles to be tightened of control criteria as 'Guidelines for discrimination ways of nonradioactive waste (not classified as radioactive waste) generated from nuclear power plants' (hereinafter referred to as 'the Guideline') was established by the Nuclear and Industrial Safety Agency of the Ministry of Economy, Trade and Industry in August, 2005. It predicts that the control criteria of monitors other than article monitors are also tightened in the future. Fuji electric has been fabricating and delivering surface contamination detecting monitors. Now we are developing the new contamination monitor corresponding to the tightening of the control criteria. 'Large article transfer monitor', 'Clothing monitor' and 'Body surface contamination monitor' are introduced in this article. (author)

  10. Occurrence of Surface Water Contaminations: An Overview

    Science.gov (United States)

    Shahabudin, M. M.; Musa, S.

    2018-04-01

    Water is a part of our life and needed by all organisms. As time goes by, the needs by human increased transforming water quality into bad conditions. Surface water contaminated in various ways which is pointed sources and non-pointed sources. Pointed sources means the source are distinguished from the source such from drains or factory but the non-pointed always occurred in mixed of elements of pollutants. This paper is reviewing the occurrence of the contaminations with effects that occurred around us. Pollutant factors from natural or anthropology factors such nutrients, pathogens, and chemical elements contributed to contaminations. Most of the effects from contaminated surface water contributed to the public health effects also to the environments.

  11. Quantification of surface contamination: principles and applications

    International Nuclear Information System (INIS)

    Vo-Dinh, T.

    1982-01-01

    The applications discussed in this paper underscore the usefulness and versatility of molecular luminescence spectroscopy as an efficient surface detection technique. The technique can be used not only as a qualitative characterization method, but also as a quantitative analytical tool to detect trace contaminants on surfaces. Recent advances in instrumentation and methodology have expanded the applicability of surface luminescence into many new problem areas. Trace organics are emphasized here

  12. Radiative Transfer Model for Contaminated Rough Surfaces

    Science.gov (United States)

    2013-02-01

    reflectance of potassium chlorate and ammonium nitrate contaminated surfaces in mid-wavelength and long-wavelength infrared for detection. Our framework...obtained excellent or good results for lab measurements of potassium chlorate on most aluminum surfaces; however, ammonium nitrate on painted aluminum...misidentify potassium chlorate as ammonium nitrate and vice versa). We also observed moderate success on field data. 15. SUBJECT TERMS radiative

  13. Contamination of optical surfaces in Earth orbit

    Science.gov (United States)

    Kinser, Donald L.; Weller, Robert A.; Mendenhall, M. H.; Wiedlocher, D. E.; Nichols, R.; Tucker, D.; Whitaker, A.

    1992-01-01

    Glass and glass ceramic samples exposed to the low earth orbit environment for approximately 5.5 years on the Long Duration Exposure Facility (LDEF) were found to display limited degradation in optical transmission. Commercial optical quality fused silica samples display decreases in transmission in the 200 to 400 nm wavelength region, and this degradation appears to be a consequence of surface contamination. The contamination, found only on internal surfaces of samples, was measured by medium energy backscattering spectrometry and found to be primarily carbon. Additional thin film contamination by a species with atomic mass near 64, which was present at the level of about 8 x 10 exp 14/sq. cm has not been identified. These observations are consistent with the interpretation that organic binders used in the black absorbing paint (Chem Glaze Z-306) inside the sample holding tray were concentrated in the vicinity of the samples and photolytically cracked by solar UV radiation. The resulting decomposition products were deposited on the interior sample surface and gave rise to the optical transmission loss. No detectable contamination was observed on the external or space exposed surface of the samples. No measurable damage was detected which could be attributed to the direct action of gamma or UV radiation on the glass samples. These results emphasize the need for special precautions in the preparation of spacecraft carrying precision optical components on long duration missions.

  14. High quality-factor quartz tuning fork glass probe used in tapping mode atomic force microscopy for surface profile measurement

    Science.gov (United States)

    Chen, Yuan-Liu; Xu, Yanhao; Shimizu, Yuki; Matsukuma, Hiraku; Gao, Wei

    2018-06-01

    This paper presents a high quality-factor (Q-factor) quartz tuning fork (QTF) with a glass probe attached, used in frequency modulation tapping mode atomic force microscopy (AFM) for the surface profile metrology of micro and nanostructures. Unlike conventionally used QTFs, which have tungsten or platinum probes for tapping mode AFM, and suffer from a low Q-factor influenced by the relatively large mass of the probe, the glass probe, which has a lower density, increases the Q-factor of the QTF probe unit allowing it to obtain better measurement sensitivity. In addition, the process of attaching the probe to the QTF with epoxy resin, which is necessary for tapping mode AFM, is also optimized to further improve the Q-factor of the QTF glass probe. The Q-factor of the optimized QTF glass probe unit is demonstrated to be very close to that of a bare QTF without a probe attached. To verify the effectiveness and the advantages of the optimized QTF glass probe unit, the probe unit is integrated into a home-built tapping mode AFM for conducting surface profile measurements of micro and nanostructures. A blazed grating with fine tool marks of 100 nm, a microprism sheet with a vertical amplitude of 25 µm and a Fresnel lens with a steep slope of 90 degrees are used as measurement specimens. From the measurement results, it is demonstrated that the optimized QTF glass probe unit can achieve higher sensitivity as well as better stability than conventional probes in the measurement of micro and nanostructures.

  15. Description of measurement techniques for surface contaminations

    International Nuclear Information System (INIS)

    Bourrez, E.

    2001-01-01

    The needs of evaluation of the surface contamination are numerous in the processes of production and management of radioactive waste. The market of radiation protection materials proposes a lot of devices answering to the almost all these needs. These device have however their conditions and particular limits for use. To realize correct measurements it is use the device, the technique and the methods adapted to the need, by taking into account the optimization of economical aspect. (N.C.)

  16. System for removing contaminated surface layers

    International Nuclear Information System (INIS)

    Yoshikawa, Kozo.

    1987-04-01

    The object of the present invention is to offer a new type of useful decontamination system, with which the contaminated surface layers can be removed effectively by injection of such solid microparticles. Liquid carbon dioxide is passed from a liquid carbon dioxide tank via the carbon dioxide supply line into the system for injecting solid carbon dioxide particles. Part of the liquid carbon dioxide introduced into the system is converted to solid carbon dioxide particles by the temperature drop resulting from adiabatic expansion in the carbon dioxide expansion space of the injection system. The solid carbon dioxide particles reach the injection nozzle, which is connected through the expansion space. The carbon dioxide microparticles are further cooled and accelerated by nitrogen gas injected from the nitrogen gas nozzle at the tip of the nitrogen gas supply line, which is connected to a liquid nitrogen tank. The cooled and accelerated solid carbon dioxide microparticles are injected from the injection nozzle for the solid carbon dioxide and directed against the contaminated surface to be cleaned, and, as a result, the surface contamination is removed

  17. Smears for determinations surface unfixed tritium contamination

    International Nuclear Information System (INIS)

    Postolache, Cristian; Matei, Lidia

    2003-01-01

    The present paper describes a method of obtaining expanded polystyrene with hydrophilized surface smears by radioinduced grafting of acrylic acid. The grafting was carried out by using a 60 Co γ radiation source. The variation of grafting rates as a function of dose range and absorbed dose was established. Grafting radiochemical rates were determined by radiometric methods using acrylic acid labeled with tritium as a grafting agent. The sampling coefficients and the reproducibility were analyzed as a function of the nature of the contaminated surface. (authors)

  18. Efficient Disinfection of Tap and Surface Water with Single High Power 285 nm LED and Square Quartz Tube

    Directory of Open Access Journals (Sweden)

    Martin Hessling

    2016-01-01

    Full Text Available A small water disinfection system based on the combination of a strong single 25 mW LED with a wavelength of 285 nm and a short quartz tube with an outer rectangular cross section is presented. For the disinfection tests clear tap water and slightly turbid and yellow pond water are contaminated with high concentrations of Escherichia coli bacteria. These water samples are exposed to the germicidal 285 nm LED radiation while they flow through the quartz tube. The portion of surviving germs is determined by membrane filtration for different water qualities and flow rates. For clear tap water the bacteria concentration can be reduced by at least three orders of magnitude up to flow rates of about 20 L/h. In pond water the maximum flow rate for such a reduction is less than 3 L/h. These high disinfection capabilities and the small size of this system, allow its integration in medical systems for point of use disinfection or even its application in the Third World for decentralized water disinfection powered by small solar cells, because this disinfection capacity should be sufficient for small groups or families.

  19. Surface integrity and part accuracy in reaming and tapping stainless steel with new vegetable based cutting oils

    DEFF Research Database (Denmark)

    Belluco, Walter; De Chiffre, Leonardo

    2002-01-01

    This paper presents an investigation on the effect of new formulations of vegetable oils on surface integrity and part accuracy in reaming and tapping operations with AISI 316L stainless steel. Surface integrity was assessed with measurements of roughness, microhardness, and using metallographic...... as part accuracy. Cutting fluids based on vegetable oils showed comparable or better performance than mineral oils. ÆÉ2002 Published by Elsevier Science Ltd....... techniques, while part accuracy was measured on a coordinate measuring machine. A widely diffused commercial mineral oil was used as reference for all measurements. Cutting fluid was found to have a significant effect on surface integrity and thickness of the strain hardened layer in the sub-surface, as well...

  20. High-technology metals as emerging contaminants: Strong increase of anthropogenic gadolinium levels in tap water of Berlin, Germany, from 2009 to 2012

    International Nuclear Information System (INIS)

    Tepe, N.; Romero, M.; Bau, M.

    2014-01-01

    Highlights: • Monitoring study Berlin-2012 confirms tap water contamination with gadolinium. • Contamination confined to western districts of Berlin. • Strong increase of anthropogenic gadolinium from 2009 to 2012. • Anthropogenic gadolinium is tracer for wastewater-derived substances. - Abstract: The distribution of rare earth elements (REE) in tap water sampled in December 2012 in Berlin, Germany, is characterized by anomalously high levels of gadolinium (Gd). While the western districts of the city show strong anthropogenic positive Gd anomalies in REE distribution patterns, the eastern districts are (almost) unaffected. This contamination with anthropogenic Gd results from Gd-based contrast agents used in Magnetic Resonance Imaging, that enter rivers, groundwater and eventually tap water via the clear water effluent from wastewater treatment plants. While the spatial distribution of anthropogenic Gd in 2012 confirms results of an earlier study in 2009 (Kulaksiz and Bau, 2011a), anthropogenic Gd concentrations have increased between 1.5- and 11.5-fold in just three years. This confirms predictions based upon the increase of anthropogenic Gd concentrations in the Havel River over the past two decades and the time it takes the water to migrate from the Havel River to the groundwater production wells. Anomalously high levels of anthropogenic Gd in tap water, which are not confined to Berlin but have also been observed in London, U.K., and in German cities in the Ruhr area and along the Rhine River, reveal that high-technology metals have become emerging contaminants. While non-toxic at the observed concentrations, the anthropogenic Gd is a microcontaminant that may be used as a conservative pseudo-natural tracer for wastewater-derived xenobiotics such as pharmaceuticals, food additives and personal care products. Our results suggest that monitoring the concentrations of such substances in Berlin’s drinking water can be restricted to a few central and

  1. Airborne iodine-125 arising from surface contamination

    International Nuclear Information System (INIS)

    Kwok, C.S.; Hilditch, T.E.

    1982-01-01

    Measurements of airborne 125 I were made during the subdivision of 740 MBq stocks of 125 I iodide solution in a hospital dispensary. Within the fume cupboard the mean airborne 125 I concentration was 3.5 +- 2.9 kBqm -3 . No airborne concentration contamination was found outside the fume cupboard during these dispensing sessions. The airborne 125 I concentration arising from deliberate surface contamination (50 μl, 3.7-6.3 MBq) of the top of a lead pot was measured at a height simulating face level at an open work bench. There was a progressive fall in airborne concentration over seven days but even then the level was still significantly above background. Measurements made with the extraction system of the fume cupboard in operation were 2-3 times lower. (U.K.)

  2. Legionella species diversity and dynamics from surface reservoir to tap water: from cold adaptation to thermophily.

    Science.gov (United States)

    Lesnik, René; Brettar, Ingrid; Höfle, Manfred G

    2016-05-01

    Water samples of the Drinking Water Supply System (DWSS) of the city of Braunschweig were analysed for its Legionella species composition using genus-specific PCR amplicons and single-strand conformation polymorphism (SSCP) fingerprint analyses based on 16S rRNA genes. These analyses comprised the whole supply chain including raw water, treatment process and large-scale storage, and a seasonal study of finished drinking water sampled monthly from cold and hot tap water. Treatment of raw water had a major impact on Legionella species by reducing their diversity and abundances. The Legionella species composition of the tap water was highly distinct from that of both source waters. In cold water, 8-14 different phylotypes of Legionella (PTLs) were observed per sample with relative abundances ranging from >1% to 53%. In hot water, L. pneumophila was present during all seasons at high relative abundances (8-40%) accompanied by 5-14 other PTLs of which 6 PTLs were in common with cold water. This thermophilic Legionella community, including L. pneumophila, was able to grow in the hot water above 50 °C. Such thermophilic Legionella populations are of general relevance for drinking water management and public health, but also for the ecology and evolution of the genus Legionella.

  3. Contamination detector for inner surface of container

    International Nuclear Information System (INIS)

    Watanabe, Tadao.

    1995-01-01

    The present invention concerns a device for detecting contamination of radioactive materials on the inner surface of a vessel upon reutilizing the vessel for containing solidified radioactive wastes and transporting them. Namely, the detecting device has following functions. (1) A radiation detector detects the radioactive materials on the inner surface of the vessel. (2) A plurality of proximity switches measure the distance from the radiation detector to the wall surface of the vessel and are actuated if the distance is decreased to a predetermined value, (3) A vessel inner surface position calculation mechanism calculates the position of the inner surface of the vessel based on the information from a direction indicator and a height indicator. (4) A frontal limit detector detects the limit for allowing the radiation detector to proceed. (5) A vessel inner shape judging mechanism for judging the shape of the inner side of the vessel based on the signals from the proximity switches in a state where the frontal limit detector is operated and a vessel inner surface position signal outputted from the vessel inner surface position calculation mechanism. As a result, the shape of the inner side of the vessel can accurately be recognized, thereby improving accuracy of radiation measurement. (I.S.)

  4. De novo biofilm community assembly from tap water source communities favors Nitrotoga over Nitrospira under elevated nitrite surface loading

    DEFF Research Database (Denmark)

    Kinnunen, Marta; Dechesne, Arnaud; Albrechtsen, Hans-Jørgen

    -through biofilm system to continuous immigration from a tap water metacommunity while applying different nitrite surface loading rates. After 63 days of operation, we extracted biofilms and analyzed the community composition via Illumina MiSeq targeting the 16S rRNA gene. Previous studies have shown...... that Nitrospira is the dominant nitrite oxidizing genus in low nitrite environments. Hence, we postulated that by elevating the nitrite surface loading we would select for NOB with lower nitrite affinity than Nitrospira. We observed different dominant NOB species under different loading rates. While...... in the metacommunity, Nitrotoga and Nitrospira were found at near equal abundances, in the biofilm community, elevated nitrite loading strongly selected for Nitrotoga over Nitrospira. The biofilms were also significantly different in their alpha-diversity (pdiversity, and the evenness and richness...

  5. Measurement and removal of surface contamination

    International Nuclear Information System (INIS)

    Neider, M.; Tamberg, T.

    1990-01-01

    This is a critical reappraisal of the sampling factor which is important for indirect contamination measurement. The factor gives the radioactivity collected by means of a wipe sample as a fraction of the total loose radioactivity i.e. without firm adhesion. It is used in national and international standard specifications and stated, frequently with excessive conservatism, as 0.1. Secondly, the standard specifications for the testing and appraisal of surface materials in relation to their decontamination capacity and for testing the effect of decontamination agents hitherto bond and Co-60 and Cs-137 are to be expanded to include radioactive iodine, which is important in nuclear medicine. The selection of optimum surface materials will thus be put on an improved basis. (orig./DG) [de

  6. Biofilm Composition and Threshold Concentration for Growth of Legionella pneumophila on Surfaces Exposed to Flowing Warm Tap Water without Disinfectant.

    Science.gov (United States)

    van der Kooij, Dick; Bakker, Geo L; Italiaander, Ronald; Veenendaal, Harm R; Wullings, Bart A

    2017-03-01

    Legionella pneumophila in potable water installations poses a potential health risk, but quantitative information about its replication in biofilms in relation to water quality is scarce. Therefore, biofilm formation on the surfaces of glass and chlorinated polyvinyl chloride (CPVC) in contact with tap water at 34 to 39°C was investigated under controlled hydraulic conditions in a model system inoculated with biofilm-grown L. pneumophila The biofilm on glass (average steady-state concentration, 23 ± 9 pg ATP cm -2 ) exposed to treated aerobic groundwater (0.3 mg C liter -1 ; 1 μg assimilable organic carbon [AOC] liter -1 ) did not support growth of the organism, which also disappeared from the biofilm on CPVC (49 ± 9 pg ATP cm -2 ) after initial growth. L. pneumophila attained a level of 4.3 log CFU cm -2 in the biofilms on glass (1,055 ± 225 pg ATP cm -2 ) and CPVC (2,755 ± 460 pg ATP cm -2 ) exposed to treated anaerobic groundwater (7.9 mg C liter -1 ; 10 μg AOC liter -1 ). An elevated biofilm concentration and growth of L. pneumophila were also observed with tap water from the laboratory. The Betaproteobacteria Piscinibacter and Methyloversatilis and amoeba-resisting Alphaproteobacteria predominated in the clones and isolates retrieved from the biofilms. In the biofilms, the Legionella colony count correlated significantly with the total cell count (TCC), heterotrophic plate count, ATP concentration, and presence of Vermamoeba vermiformis This amoeba was rarely detected at biofilm concentrations of water-associated disease outbreaks reported in the United States. The organism proliferates in biofilms on surfaces exposed to warm water in engineered freshwater installations. An investigation with a test system supplied with different types of warm drinking water without disinfectant under controlled hydraulic conditions showed that treated aerobic groundwater (0.3 mg liter -1 of organic carbon) induced a low biofilm concentration that supported no or very

  7. Analysis of surface contaminants on beryllium and aluminum windows

    International Nuclear Information System (INIS)

    Gmur, N.F.

    1987-06-01

    An effort has been made to document the types of contamination which form on beryllium window surfaces due to interaction with a synchrotron radiation beam. Beryllium windows contaminated in a variety of ways (exposure to water and air) exhibited surface powders, gels, crystals and liquid droplets. These contaminants were analyzed by electron diffraction, electron energy loss spectroscopy, energy dispersive x-ray spectroscopy and wet chemical methods. Materials found on window surfaces include beryllium oxide, amorphous carbon, cuprous oxide, metallic copper and nitric acid. Aluminum window surface contaminants were also examined

  8. Developments in surface contamination and cleaning fundamentals and applied aspects

    CERN Document Server

    Kohli, Rajiv

    2015-01-01

    Developments in Surface Contamination and Cleaning, Vol. 1: Fundamentals and Applied Aspects, Second Edition, provides an excellent source of information on alternative cleaning techniques and methods for characterization of surface contamination and validation. Each volume in this series contains a particular topical focus, covering the key techniques and recent developments in the area. This volume forms the heart of the series, covering the fundamentals and application aspects, characterization of surface contaminants, and methods for removal of surface contamination. In addition, new cleaning techniques effective at smaller scales are considered and employed for removal where conventional cleaning techniques fail, along with new cleaning techniques for molecular contaminants. The Volume is edited by the leading experts in small particle surface contamination and cleaning, providing an invaluable reference for researchers and engineers in R&D, manufacturing, quality control, and procurement specific...

  9. Bonding of radioactive contamination. IV. Effect of surface finish

    International Nuclear Information System (INIS)

    Rankin, W.N.

    1983-01-01

    The mechanisms by which radioactive contamination would be bonded to a DWPF canister are being investigated. Previous investigations in this series have examined the effects of temperature, oxidation before contamination, and atmosphere composition control on the bonding of contamination. This memorandum describes the results of tests to determine the effect of special surface finishes on the bonding of contamination to waste glass canisters. Surface pretreatments which produce smoother canister surfaces actually cause radioactive contamination to be more tightly bonded to the metal surface than on an untreated surface. Based on the results of these tests it is recommended that the canister surface finish be specified as having a bright cold rolled mill finish equivalent to ASTM No. 2B. 7 references, 3 figures, 3 tables

  10. Improvement of a device for monitoring the contamination of surfaces

    International Nuclear Information System (INIS)

    Barbier, Albert.

    1981-01-01

    The purpose of this invention is to make it possible to monitor the contamination of surfaces by a light weight portable device and enabling the alpha, beta and gamma radiation contamination to be detected. The detection probe which is connected by a single lead to the box is adapted, in each particular case, to the radiation mode emitted by the contaminated surfaces and the box is provided with a special leak-proof socket for connecting the probe and includes means for assessing the counting rate of the radiation given off, depending on the mode of the radiations emitted by the contaminated surfaces and the intensity of the count rate [fr

  11. Removal and treatment of radioactive, organochlorine, and heavy metal contaminants from solid surfaces

    International Nuclear Information System (INIS)

    Grieco, S.A.; Neubauer, E.D.

    1996-01-01

    The U.S. Department of Energy (DOE) is defining decontamination and decommissioning (D ampersand D) obligations at its sites. Current D ampersand D activities are generally labor intensive, use chemical reagents that are difficult to treat, and may expose workers to radioactive and hazardous chemicals. Therefore, new technologies are desired that minimize waste, allow much of the decommissioned materials to be reused rather than disposed of as waste, and produce wastes that will meet disposal criteria. The O'Brien ampersand Gere companies tested a scouring decontamination system on concrete and steel surfaces contaminated with radioactive and hazardous wastes under the sponsorship of Martin Marietta Energy Systems, Inc. (MMES) at DOE's K-25 former gaseous diffusion plant in Oak Ridge, Tennessee. The scouring system removes fixed radioactive and hazardous contamination yet leaves the surface intact. Blasting residuals are treated using physical/chemical processes. Bench- and pilot-scale testing of the system was conducted on surfaces contaminated with uranium, technetium, heavy metals, and PCBs. Areas of concrete and metal surfaces were blasted. Residuals were dissolved in tap water and treated for radioactive, hazardous, and organochlorine constituents. The treatment system comprised pH adjustment, aeration, solids settling, filtration, carbon adsorption, and ion exchange. This system produced treated water and residual solid waste. Testing demonstrated that the system is capable of removing greater than 95% of radioactive and PCB surface contamination to below DOE's unrestricted use release limits; aqueous radionuclides, heavy metals, and PCBs were below DOE and USEPA treatment objectives after treatment. Waste residuals volume was decreased by 71 %. Preliminary analyses suggest that this system provides significant waste volume reduction and is more economical than alternative surface decontamination techniques that are commercially available or under development

  12. Investigation of Fungi in Drinking Water Resources as a Source of Contamination Tap Water in Sari, Iran

    Directory of Open Access Journals (Sweden)

    Z Yousefi

    2013-06-01

    Full Text Available Background and purpose: One of the most prominent concerns for the water consumers is pathogenic microorganism contamination. Wells and underground water resources are the main resources of drinking water in Sari city, Iran. The main objectives of the research project were to explore the distribution and frequency of mycoflora in wells and underground water resources of the city and their contamination effects on humans. Materials and methods: Three reservoirs and 18 wells or underground water resources were analyzed. Water samples were then filtered and analyzed according to the World Health Organization guidelines. Each filter and 0.2 ml of suspension inoculated on SDA+CG media. For fungal growth, plates were incubated at 27’C for 7-10 days. The fungi were identified by standard mycological techniques. Results: Fungal colonies were isolated from all samples. From total of 160 fungal colonies isolated from wells water, 14 species of fungi were distinguished. Rhodotorula (54.4%, Monilinia (13.7%, Alternaria (6.9% were the most commonly isolated. Drechslera, Rhizopus, and Exserohilum (0.6% had the lowest frequency. There was no significant difference between fungal elements isolated from three major reservoirs (P>0.05. Conclusion: This study revealed that resources of drinking water from an area have to monitored and if its fungal CFU be greater than a certain value, medical and health preventive measures should be taken before the water is used by human. In this context, public and private awareness should also be provided through the media, broadcasting, teachers and scholars.

  13. Body-surface contamination monitoring preparatory to monitoring for internal contamination

    International Nuclear Information System (INIS)

    Schlueter, W.; Klucke, H.

    1980-01-01

    Measurements in the whole-body counter of the SAAS are routinely preceded by a thorough inspection of the patients for body-surface contamination to protect the sensitive counting equipment against becoming contaminated and to avoid a falsified indication of incorporated radionuclides. The measuring system employed for these examinations is described. (author)

  14. Decontamination of plutonium-contaminated surfaces

    International Nuclear Information System (INIS)

    Bertrand, J.; Clouet d'Orval, Ch.; Tachon, J.

    1958-01-01

    The measure of the neutron distribution in the core of 'Proserpine', by means of activation detectors, requires no contact between the plutonium sulfate solution and the detectors. These detectors are put into PVC or polyethylene bags. This report describes the process used to decontaminate these bags. A washing by nitric acid followed by coating with plexiglass is kept, with this process we have no contamination on the detectors. (author) [fr

  15. Total effective dose equivalent associated with fixed uranium surface contamination

    International Nuclear Information System (INIS)

    Bogard, J.S.; Hamm, R.N.; Ashley, J.C.; Turner, J.E.; England, C.A.; Swenson, D.E.; Brown, K.S.

    1997-04-01

    This report provides the technical basis for establishing a uranium fixed-contamination action level, a fixed uranium surface contamination level exceeding the total radioactivity values of Appendix D of Title 10, Code of Federal Regulations, part 835 (10CFR835), but below which the monitoring, posting, and control requirements for Radiological Areas are not required for the area of the contamination. An area of fixed uranium contamination between 1,000 dpm/100 cm 2 and that level corresponding to an annual total effective dose equivalent (TEDE) of 100 mrem requires only routine monitoring, posting to alert personnel of the contamination, and administrative control. The more extensive requirements for monitoring, posting, and control designated by 10CFR835 for Radiological Areas do not have to be applied for these intermediate fixed-contamination levels

  16. Modeling of laser damage initiated by surface contamination

    International Nuclear Information System (INIS)

    Feit, M.D.; Rubenchik, A.M.; Faux, D.R.; Riddle, R.A.; Shapiro, A.; Eder, D.C.; Penetrante, B.M.; Milam, D.; Genin, F.Y.; Kozlowski, M.R.

    1996-11-01

    The authors are engaged in a comprehensive effort to understand and model the initiation and growth of laser damage initiated by surface contaminants. This includes, for example, the initial absorption by the contaminant, heating and plasma generation, pressure and thermal loading of the transparent substrate, and subsequent shockwave propagation, 'splashing' of molten material and possible spallation, optical propagation and scattering, and treatment of material fracture. The integration use of large radiation hydrodynamics codes, optical propagation codes and material strength codes enables a comprehensive view of the damage process The following picture of surface contaminant initiated laser damage is emerging from our simulations

  17. Optimization in the nuclear fuel cycle II: Surface contamination

    International Nuclear Information System (INIS)

    Pereira, W.S.; Silva, A.X.; Lopes, J.M.; Carmo, A.S.; Fernandes, T.S.; Mello, C.R.; Kelecom, A.

    2017-01-01

    Optimization is one of the bases of radioprotection and aims to move doses away from the dose limit that is the borderline of acceptable radiological risk. This work aims to use the monitoring of surface contamination as a tool of the optimization process. 53 surface contamination points were analyzed at a nuclear fuel cycle facility. Three sampling points were identified with monthly mean values of contamination higher than 1 Bq ∙ cm -2 , points 28, 42 and 47. These points were indicated for the beginning of the optimization process

  18. Automatic Measurement of Low Level Contamination on Concrete Surfaces

    International Nuclear Information System (INIS)

    Tachibana, M.; Itoh, H.; Shimada, T.; Yanagihara, S.

    2002-01-01

    Automatic measurement of radioactivity is necessary for considering cost effectiveness in final radiological survey of building structures in decommissioning nuclear facilities. The RAPID (radiation measuring pilot device for surface contamination) was developed to be applied to automatic measurement of low level contamination on concrete surfaces. The RAPID has a capability to measure contamination with detection limit of 0.14 Bq/cm2 for 60Co in 30 seconds of measurement time and its efficiency is evaluated to be 5 m2/h in a normal measurement option. It was confirmed that low level contamination on concrete surfaces could be surveyed by the RAPID efficiently compared with direct measurement by workers through its actual application

  19. Automation system for tritium contaminated surface monitoring

    International Nuclear Information System (INIS)

    Culcer, Mihai; Iliescu, Mariana; Curuia, Marian; Raceanu, Mircea; Enache, Adrian; Stefanescu, Ioan; Ducu, Catalin; Malinovschi, Viorel

    2005-01-01

    The low energy of betas makes tritium difficult to detect. However, there are several methods used in tritium detection, such as liquid scintillation and ionization chambers. Tritium on or near a surface can be also detected using proportional counter and, recently, solid state devices. The paper presents our results in the design and achievement of a surface tritium monitor using a PIN photodiode as a solid state charged particle detector to count betas emitted from the surface. That method allows continuous, real-time and non-destructively measuring of tritium. (authors)

  20. Estimating dermal transfer from PCB-contaminated porous surfaces.

    Science.gov (United States)

    Slayton, T M; Valberg, P A; Wait, A D

    1998-06-01

    Health risks posed by dermal contact with PCB-contaminated porous surfaces have not been directly demonstrated and are difficult to estimate indirectly. Surface contamination by organic compounds is commonly assessed by collecting wipe samples with hexane as the solvent. However, for porous surfaces, hexane wipe characterization is of limited direct use when estimating potential human exposure. Particularly for porous surfaces, the relationship between the amount of organic material collected by hexane and the amount actually picked up by, for example, a person's hand touch is unknown. To better mimic PCB pickup by casual hand contact with contaminated concrete surfaces, we used alternate solvents and wipe application methods that more closely mimic casual dermal contact. Our sampling results were compared to PCB pickup using hexane-wetted wipes and the standard rubbing protocol. Dry and oil-wetted samples, applied without rubbing, picked up less than 1% of the PCBs picked up by the standard hexane procedure; with rubbing, they picked up about 2%. Without rubbing, saline-wetted wipes picked up 2.5%; with rubbing, they picked up about 12%. While the nature of dermal contact with a contaminated surface cannot be perfectly reproduced with a wipe sample, our results with alternate wiping solvents and rubbing methods more closely mimic hand contact than the standard hexane wipe protocol. The relative pickup estimates presented in this paper can be used in conjunction with site-specific PCB hexane wipe results to estimate dermal pickup rates at sites with PCB-contaminated concrete.

  1. Process for cleaning radioactively contaminated metal surfaces

    International Nuclear Information System (INIS)

    Mihram, R.G.; Snyder, G.A.

    1975-01-01

    A process is described for removing radioactive scale from a ferrous metal surface, including the steps of initially preconditioning the surface by contacting it with an oxidizing solution (such as an aqueous solution of an alkali metal permanganate or hydrogen peroxide), then, after removal or decomposition of the oxidizing solution, the metallic surface is contacted with a cleaning solution which is a mixture of a mineral acid and a complexing agent (such as sulfuric acid and oxalic acid), and which preferably contains a corrosion inhibitor. A final step in the process is the treatment of the spent cleaning solution containing radioactive waste materials in solution by adding a reagent selected from the group consisting of calcium hydroxide or potassium permanganate and an alkali metal hydroxide to thereby form easily recovered metallic compounds containing substantially all of the dissolved metals and radioactivity. (auth)

  2. Cleaning, disinfection and sterilization of surface prion contamination.

    Science.gov (United States)

    McDonnell, G; Dehen, C; Perrin, A; Thomas, V; Igel-Egalon, A; Burke, P A; Deslys, J P; Comoy, E

    2013-12-01

    Prion contamination is a risk during device reprocessing, being difficult to remove and inactivate. Little is known of the combined effects of cleaning, disinfection and sterilization during a typical reprocessing cycle in clinical practice. To investigate the combination of cleaning, disinfection and/or sterilization on reducing the risk of surface prion contamination. In vivo test methods were used to study the impact of cleaning alone and cleaning combined with thermal disinfection and high- or low-temperature sterilization processes. A standardized test method, based on contamination of stainless steel wires with high titres of scrapie-infected brain homogenates, was used to determine infectivity reduction. Traditional chemical methods of surface decontamination against prions were confirmed to be effective, but extended steam sterilization was more variable. Steam sterilization alone reduced the risk of prion contamination under normal or extended exposure conditions, but did show significant variation. Thermal disinfection had no impact in these studies. Cleaning with certain defined formulations in combination with steam sterilization can be an effective prion decontamination process, in particular with alkaline formulations. Low-temperature, gaseous hydrogen peroxide sterilization was also confirmed to reduce infectivity in the presence and absence of cleaning. Prion decontamination is affected by the full reprocessing cycle used on contaminated surfaces. The correct use of defined cleaning, disinfection and sterilization methods as tested in this report in the scrapie infectivity assay can provide a standard precaution against prion contamination. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  3. Ultrasensitive and selective gold film-based detection of mercury (II) in tap water using a laser scanning confocal imaging-surface plasmon resonance system in real time.

    Science.gov (United States)

    Zhang, Hongyan; Yang, Liquan; Zhou, Bingjiang; Liu, Weimin; Ge, Jiechao; Wu, Jiasheng; Wang, Ying; Wang, Pengfei

    2013-09-15

    An ultrasensitive and selective detection of mercury (II) was investigated using a laser scanning confocal imaging-surface plasmon resonance system (LSCI-SPR). The detection limit was as low as 0.01ng/ml for Hg(2+) ions in ultrapure and tap water based on a T-rich, single-stranded DNA (ssDNA)-modified gold film, which can be individually manipulated using specific T-Hg(2+)-T complex formation. The quenching intensity of the fluorescence images for rhodamine-labeled ssDNA fitted well with the changes in SPR. The changes varied with the Hg(2+) ion concentration, which is unaffected by the presence of other metal ions. The coefficients obtained for ultrapure and tap water were 0.99902 and 0.99512, respectively, for the linear part over a range of 0.01-100ng/ml. The results show that the double-effect sensor has potential for practical applications with ultra sensitivity and selectivity, especially in online or real-time monitoring of Hg(2+) ions pollution in tap water with the further improvement of portable LSCI-SPR instrument. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Tapping mode AFM study on the surface dynamics of a single glucose oxidase molecule on a Au(1 1 1) surface in water with implication for a surface-induced unfolding pathway

    International Nuclear Information System (INIS)

    Otsuka, Ichiro; Yaoita, Masashi; Higano, Michi; Nagashima, Seiiichi; Kataoka, Ryoichi

    2004-01-01

    We have investigated a surface-induced unfolding dynamics of a single glucose oxidase (GO) molecule on Au(1 1 1) in air-saturated water, using tapping mode atomic force microscopy (TMAFM). We followed the unfolding process by measuring the maximum height of a well-isolated GO molecule on a terrace near a step-edge of the surface as a function of contact time. We find three linear portions with two intersections in a power-law fit to the selected values of the observed heights. The kinetic TMAFM result implies that there exist at least two distinct dynamic regimes in the unfolding

  5. Analysis of surface contaminants on beryllium windows

    International Nuclear Information System (INIS)

    Gmur, N.F.

    1986-12-01

    It is known that various crystalline and liquid compounds form on the downstream surfaces of beryllium windows exposed to air. It is also known that the integrity of such windows may be compromised resulting in leaks through the window. The purpose of this report is to document the occurrences described as they pertain to the NSLS and to analyze, where possible, the various substances formed

  6. Release of Streptomyces albus propagules from contaminated surfaces

    International Nuclear Information System (INIS)

    Gorny, R.L.; Mainelis, Gediminas; Grinshpun, Sergey A.; Willeke, Klaus; Dutkiewicz, Jacek; Reponen, Tiina

    2003-01-01

    The release of Streptomyces albus propagules from contaminated agar an ceiling tile surfaces was studied under controlled environmental condition in a newly developed aerosolization chamber. The experiments revealed tha both spores and cell fragments can be simultaneously released from the colonized surface by relatively gentle air currents of 0.3 m s -1 . A 100x increase of the air velocity can result in a 50-fold increase in the number of released propagules. The aerosolization rate depends strongly on the typ and roughness of the contaminated surface. Up to 90% of available actinomycete propagules can become airborne during the first 10 min of th release process. Application of vibration to the surface did not reveal an influence on the aerosolization process of S. albus propagules under th tested conditions. This study has shown that propagules in the fine particle size range can be released in large amounts from contaminated surfaces Measurement of the number of S. albus fragments in the vicinity of contaminated area, as an alternative to conventional air or surface sampling appears to be a promising approach for quantitative exposure assessment

  7. 10 years with TAPS

    International Nuclear Information System (INIS)

    Loehneer, H.

    1997-01-01

    During the IV TAPS (two arm photon spectrometer) workshop held at Mont Saint Odile near Strasbourg the third of September, the TAPS collaboration celebrated its 10. anniversary. At this occasion a compilation entitled 'The first 10 years with TAPS' was issued. The foreword of the spokesperson of the TAPS collaboration is presented. (K.A.)

  8. Techniques for removing contaminants from optical surfaces

    International Nuclear Information System (INIS)

    Stowers, I.F.; Patton, H.G.

    1978-01-01

    Particle removal procedures such as plasma cleaning, ultrasonic agitation of solvents, detergents, solvent wiping, mild abrasives, vapor degreasing, high pressure solvent spraying and others have been evaluated and the results are reported here. Wiping with a lens tissue wetted with an organic solvent and high pressure fluid spraying are the only methods by which particles as small as 5 μm can be effectively removed. All of the other methods tested were found to be at least two orders of magnitude less effective at removing small insoluble particles. An additional and as yet unresolved problem is the development of a reliable method for evaluating particulate surface cleanliness. Without such a reproducible monitoring technique, the large diversity of cleaning methods currently available cannot be quantitatively evaluated

  9. Monitoring of tritium-contaminated surfaces, including skin

    Energy Technology Data Exchange (ETDEWEB)

    Surette, R A; Wood, M J

    1994-05-01

    We have examined various commercially available tritium surface contamination monitors along with different swipe media and techniques for direct and indirect (swipe) monitoring of contaminated surfaces, including skin. None of the methods or instruments evaluated were more sensitive than the swipe and liquid scintillation counting (LSC) method. Swipe measurements with open-window proportional counters were, in general, less than half as sensitive as LSC, but have the advantages of having the results available almost immediately, and no sample preparation is required. The Nuclear Measurement Corporation`s PC-55 is the most suitable instrument we tested for the analysis of routine swipe measurement. The PC-55 was about one third as sensitive as LSC when used with Ontario Hydro filter paper swipe media. Surface contamination measurement results can be obtained within minutes using the PC-55, compared to hours using LSC. The selection of swipe media for use with proportional counter-based instruments is critical. A medium that is electrically insulating can develop an electrostatic charge on its surface; this may alter the field gradient in the detector and may adversely influence the results. Although the PC-55 is sufficiently sensitive and very convenient, operational experience with the instrument is needed before recommending that it replace current LSC methods. The PC-55`s susceptibility to internal tritium contamination may limit its practical usefulness. Because of the complexity of using live animals to evaluate direct and indirect methods for assessing skin contamination, pig skin was investigated as a possible substitute. We concluded that, for the first few hours post-exposure, pig skin mimics the kinetics of animal skin that has contacted a tritium-contaminated surface. (author). 30 refs., 1 tab., 7 figs.

  10. Monitoring of tritium-contaminated surfaces, including skin

    International Nuclear Information System (INIS)

    Surette, R.A.; Wood, M.J.

    1994-05-01

    We have examined various commercially available tritium surface contamination monitors along with different swipe media and techniques for direct and indirect (swipe) monitoring of contaminated surfaces, including skin. None of the methods or instruments evaluated were more sensitive than the swipe and liquid scintillation counting (LSC) method. Swipe measurements with open-window proportional counters were, in general, less than half as sensitive as LSC, but have the advantages of having the results available almost immediately, and no sample preparation is required. The Nuclear Measurement Corporation's PC-55 is the most suitable instrument we tested for the analysis of routine swipe measurement. The PC-55 was about one third as sensitive as LSC when used with Ontario Hydro filter paper swipe media. Surface contamination measurement results can be obtained within minutes using the PC-55, compared to hours using LSC. The selection of swipe media for use with proportional counter-based instruments is critical. A medium that is electrically insulating can develop an electrostatic charge on its surface; this may alter the field gradient in the detector and may adversely influence the results. Although the PC-55 is sufficiently sensitive and very convenient, operational experience with the instrument is needed before recommending that it replace current LSC methods. The PC-55's susceptibility to internal tritium contamination may limit its practical usefulness. Because of the complexity of using live animals to evaluate direct and indirect methods for assessing skin contamination, pig skin was investigated as a possible substitute. We concluded that, for the first few hours post-exposure, pig skin mimics the kinetics of animal skin that has contacted a tritium-contaminated surface. (author). 30 refs., 1 tab., 7 figs

  11. Worker exposures from recycling surface contaminated radioactive scrap metal

    International Nuclear Information System (INIS)

    Kluk, A.; Phillips, J.W.; Culp, J.

    1996-01-01

    Current DOE policy permits release from DOE control of real property with residual levels of surficial radioactive contamination if the contamination is below approved guidelines. If the material contains contamination that is evenly distributed throughout its volume (referred to as volumetric contamination), then Departmental approval for release must be obtained in advance. Several DOE sites presently recycle surface contaminated metal, although the quantities are small relative to the quantities of metal processed by typical mini-mills, hence the potential radiation exposures to mill workers from processing DOE metals and the public from the processed metal are at present also a very small fraction of their potential value. The exposures calculated in this analysis are based on 100% of the scrap metal being processed at the maximum contamination levels and are therefore assumed to be maximum values and not likely to occur in actual practice. This paper examines the relationship between the surface contamination limits established under DOE Order 5400.5, open-quotes Radiation Protection of the Public and the Environment,close quotes and radiation exposures to workers involved in the scrap metal recycling process. The analysis is limited to surficial contamination at or below the guideline levels established in DOE Order 5400.5 at the time of release. Workers involved in the melting and subsequent fabrication of products are not considered radiation workers (no requirements for monitoring) and must be considered members of the public. The majority of the exposures calculated in this analysis range from tenths of a millirem per year (mrem/yr) to less than 5 mrem/yr. The incremental risk of cancer associated with these exposures ranges from 10 -8 cancers per year to 10 -6 cancers per year

  12. Modelling of contamination of surface atmosphere for deflation of Cesium-137 on contaminated territories

    International Nuclear Information System (INIS)

    Bogdanov, A.P.; Zhmura, G.M.

    1994-01-01

    Presence of Cesium 137 in near land air is caused at the contaminated territories by 'local' dusting and transport of the dust from the zone of strong contamination. For large distance is it caused by resuspension of radioactive dust from the surface in the given region. In accordance with the models of dusting round square sources based on Gauss statistical model of dissemination of admixtures in the atmosphere, the contaminated areas of european part of the former of USSR with the density of contamination over 1 Ci/km 2 with Cesium 137 were represented by 30 round square sources covering the main spots of contamination. The results of calculation of contamination of the atmosphere for several cities of Belarus, Russia and Ukraine, where there are the permanent points of observation for the content of radionuclides in the air, have shown that the proposed model of dusting sources describes the contamination of near land air with Cesium 137 reasonably well. 7 refs., 3 tabs

  13. Assessment of arsenic surface contamination in a museum anthropology department.

    Science.gov (United States)

    Gribovich, Andrey; Lacey, Steven; Franke, John; Hinkamp, David

    2013-02-01

    To assess potential arsenic (As) contamination of work surfaces to improve upon the control strategy at an anthropology department in a large natural history museum. Work practices were observed and control strategy reviewed to inform an occupational hygiene assessment strategy utilizing surface wipe sampling. A total of 35 sampling targets were identified, focusing on surfaces that receive high touch traffic, including workstations, artifact transport carts, and elevator buttons. Arsenic sampling and analysis were performed using reference method Occupational Safety and Health Administration ID-125G. Four of the sampling areas returned detectable levels of As, ranging from 0.052 to 0.350 μg/100 cm. Workplace observations and wipe sampling data enabled the development of recommendations to help to further reduce potential occupational exposure to As. Continuous reduction of surface contamination is prudent for known human carcinogens.

  14. Development of a calibration system for surface contamination monitors

    International Nuclear Information System (INIS)

    Marechal, M.H.H.; Barbosa, M.P.

    1992-01-01

    A calibration system for surface contamination monitors is developed, aiming supply the existence demand of these instruments. A experimental arrangement and a methodology are described. The advantages of use this system for calibration routine optimization are also discussed. (C.G.C.)

  15. Influence of the target surface contamination on UHV screening energies

    Energy Technology Data Exchange (ETDEWEB)

    Targosz-Sleczka, N; Czerski, K; Kilic, A I [Institute of Physics, University of Szczecin, Szczecin (Poland); Huke, A; Martin, L; Heide, P [Institut fuer Atomare Physik und Optik, Technische Universitaet Berlin, Berlin (Germany); Blauth, D; Winter, H, E-mail: natalia.targosz@wmf.univ.szczecin.p [Institut fuer Physik, Humboldt-Universitaet zu Berlin, Berlin (Germany)

    2010-01-01

    The d + d fusion reactions have been investigated in the Zirconium environment under ultra high vacuum (UHV) conditions for projectile energies below 30 keV. The experimentally determined screening energy value of 497 {+-} 7 eV is larger than the previous results by a factor of almost two. Despite the UHV conditions a small deviation between experimental data and the theoretical curve arising from the target surface contamination could be still observed at the lowest projectile energies. Calculations made under the assumption of formation of a Zirconium oxide contamination, show that every atomic monolayer reduces the estimated screening energy significantly.

  16. Influence of the target surface contamination on UHV screening energies

    International Nuclear Information System (INIS)

    Targosz-Sleczka, N; Czerski, K; Kilic, A I; Huke, A; Martin, L; Heide, P; Blauth, D; Winter, H

    2010-01-01

    The d + d fusion reactions have been investigated in the Zirconium environment under ultra high vacuum (UHV) conditions for projectile energies below 30 keV. The experimentally determined screening energy value of 497 ± 7 eV is larger than the previous results by a factor of almost two. Despite the UHV conditions a small deviation between experimental data and the theoretical curve arising from the target surface contamination could be still observed at the lowest projectile energies. Calculations made under the assumption of formation of a Zirconium oxide contamination, show that every atomic monolayer reduces the estimated screening energy significantly.

  17. Laser Decontamination of Surfaces Contaminated with Cs+ Ion

    International Nuclear Information System (INIS)

    Baigalmaaa, B.; Won, H. J.; Moon, J. K.; Jung, C. H.; Lee, K. W.; Hyun, J. H.

    2008-01-01

    Laser decontamination technology has been proven to be an efficient method for a surface modification of metals and concretes contaminated with radioactive isotopes. Furthermore, the generation of a secondary waste is negligible. The radioactivity of hot cells in the DFDF (Dupic Fuel Development Facility) is presumed to be very high and the predominant radionuclide is Cs-137. A series of laser decontamination studies by a fabricated Q-switched Nd:YAG laser system were performed on stainless steel specimens artificially contaminated with Cs+ ion. Decontamination characteristics of the stainless steel were analyzed by SEM and EPMA

  18. Strippable gel for decontamination of contaminated metallic surfaces

    International Nuclear Information System (INIS)

    Banerjee, D.; Sandhya, U.; Khot, S.A.; Srinivas, C.; Wattal, P.K.

    2013-01-01

    Periodic decontamination of radioactive laboratories including fume hoods, glove boxes and all surfaces used for handling, processing and transporting radioactive materials is mandatory in all nuclear installations as this reduces spread of contamination and decreases total man rem exposure. Conventionally, chemical decontaminating agents or surfactant solutions are used for this purpose. However, this approach leads to generation of large volume of secondary radioactive waste. The use of strippable gel is an attractive alternative with low secondary waste generation particularly where removal of loose or weakly fixed contamination is necessary and also when the decontaminated material are to be reused, for e.g. decontamination of fume hoods, glove boxes, transport casks, spent fuel storage racks, control rod drive transport containers etc. Literature on gel formulations is scarce and mostly in the patent form. The sustained effort on gel formulation development has resulted in a basic gel formulation. The gel is a highly viscous water-based organic polymer, particularly suitable for application on vertical surfaces including difficult to reach metallic surfaces of complex geometry and not just limited to horizontal surfaces. The gel can be easily applied on contaminated surfaces by brushing or spraying. Curing of the gel is complete within 16-24 hours under ambient conditions and can then be removed by peeling as a dry sheet. While curing, the contaminants are trapped in gel either physically or chemically depending upon the nature of the contaminant. Salient features of cured gel include that it is water soluble and can be disposed off after immobilization in cement. Decontamination performance of the gel was initially evaluated by applying it on SS planchettes contaminated with known amount of radionuclides such as Cs(I), Co(II) and Ce(III). The measured decontamination factor was found to be in the range of 50-500, lowest for Ce(III) and highest for Co

  19. Experiment on Physical Desalinisation of Uranium-contaminated Gravel Surface

    International Nuclear Information System (INIS)

    Park, Uk-Ryang; Kim, Gye-Nam; Kim, Seung-Soo; Han, Gyu-Seong; Moon, Jai-Kwon

    2014-01-01

    As a result, the method to wash uranium-contaminated gravels could not get satisfactory desalinization rate. During the long oxidization process it was judged that uranium penetrated inside the gravels, so we tried to increase the desalinization rate by fragmentizing them into pieces and then washing them. The desalinization rate after fragmentizing the gravels into pieces and washing them brought a satisfactory result.. However, we could obtain desired concentration for gravels with high uranium concentration by fragmentizing them and breaking them further into even smaller pieces. Likewise, desalinization using soil washing process is complicated and has to go through multiple washing steps, resulting in too much of waste fluid generated accordingly. The increase of waste fluid generated leads to the increase in by-products of the final disposal process later on, bringing a not good economic result. Furthermore, taking into account that the desalinization rate is 65% during soil washing process, it is expected that gravel washing will show a similar desalinization result; it is considered uneasy to have a perfect desalinization only by soil washing. The grinding method is actually used in the primary desalinization process in order to desalinize radioactivity-contaminated concrete. This method does desalinization by grinding the radioactivity-contaminated area of the concrete surface with desalinization equipment, which enables a near-to-perfect desalinization for relatively thinly contaminated surface. Likewise, this research verified the degree of desalinization by applying the grinding method and comparing it to the fragmentizing-washing method, and attempted to find a method to desalinize uranium-contaminated gravels more effectively. In order to desalinize uranium-contaminated gravels more effectively and compare to the existing washing-desalinization method, we conducted a desalinization experiment with grinding method that grinds gravel surface. As a

  20. Residual viral and bacterial contamination of surfaces after cleaning and disinfection

    NARCIS (Netherlands)

    Tuladhar, E.; Hazeleger, W.C.; Koopmans, M.; Zwietering, M.H.; Beumer, R.R.; Duizer, E.

    2012-01-01

    Environmental surfaces contaminated with pathogens can be sources of indirect transmission, and cleaning and disinfection are common interventions focused on reducing contamination levels. We determined the efficacy of cleaning and disinfection procedures for reducing contamination by noroviruses,

  1. Reactor surface contamination stabilization. Innovative technology summary report

    International Nuclear Information System (INIS)

    1998-11-01

    Contaminated surfaces, such as the face of a nuclear reactor, need to be stabilized (fixed) to avoid airborne contamination during decontamination and decommissioning activities, and to prepare for interim safe storage. The traditional (baseline) method of fixing the contamination has been to spray a coating on the surfaces, but ensuring complete coverage over complex shapes, such as nozzles and hoses, is difficult. The Hanford Site C Reactor Technology Demonstration Group demonstrated innovative technologies to assess stabilization properties of various coatings and to achieve complete coverage of complex surfaces on the reactor face. This demonstration was conducted in two phases: the first phase consisted of a series of laboratory assessments of various stabilization coatings on metal coupons. For the second phase, coatings that passed the laboratory tests were applied to the front face of the C Reactor and evaluated. The baseline coating (Rust-Oleum No. 769) and one of the innovative technologies did not completely cover nozzle assemblies on the reactor face, the most critical of the second-phase evaluation criteria. However, one of the innovative coating systems, consisting of a base layer of foam covered by an outer layer of a polymeric film, was successful. The baseline technology would cost approximately 33% as much as the innovative technology cost of $64,000 to stabilize an entire reactor face (196 m 2 or 2116 ft 2 ) with 2,004 nozzle assemblies, but the baseline system failed to provide complete surface coverage

  2. Removable coating for contamination protection of concrete surface

    International Nuclear Information System (INIS)

    Brambilla, G.; Beaulardi, L.

    1985-01-01

    In order to research protective coatings for concrete surfaces, assuring an effective protection against contamination and that it be easily removed before dismantling the structures, commercial stripping paints have been characterized for their conventional and nuclear properties: water and chemicals, abrasion, impact, tensile stress resistance, stripping capacity, decontaminability. The protective power of the coatings against contamination has been checked by recording the surface activity before and after stripping the paint film: the activity filtered through the coating was, in any case, very low (< 1% of the deposited activity). Indications from large scale application of a stripping paint in NUCLEO (Rome) establishments and technical evaluation of the possible utilization of removable coatings in the CAORSO Nuclear Power Station, are also reported

  3. Nickel in tap water

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Nielsen, G D; Flyvholm, Morten

    1983-01-01

    Nickel analyses of tap water from several sources in Copenhagen gave up to 490 X 10(-6) g X 1(-1) in the first 250 ml portions. Hot water gave higher values than cold water. After flushing for 5 min, low values were found. Considerable variation from time to time and from tap to tap was found...

  4. Modeling Groundwater-Surface Water Interaction and Contaminant Transport of Chlorinated Solvent Contaminated Site

    Science.gov (United States)

    Yimer Ebrahim, Girma; Jonoski, Andreja; van Griensven, Ann; Dujardin, Juliette; Baetelaan, Okke; Bronders, Jan

    2010-05-01

    Chlorinated-solvent form one of the largest groups of environmental chemicals. Their use and misuse in industry have lead to a large entry of these chemicals into the environment, resulting in widespread dissemination and oftentimes environmental contamination. Chlorinated solvent contamination of groundwater resources has been widely reported. For instance, there has been much interest in the assessment of these contaminant levels and their evolutions with time in the groundwater body below the Vilvoorde-Machelen industrial area (Belgium). The long industrial history of the area has lead to complex patterns of pollution from multiple sources and the site has been polluted to the extent that individual plumes are not definable any more. Understanding of groundwater/surface water interaction is a critical component for determining the fate of contaminant both in streams and ground water due to the fact that groundwater and surface water are in continuous dynamic interaction in the hydrologic cycle. The interaction has practical consequences in the quantity and quality of water in either system in the sense that depletion and/or contamination of one of the system will eventually affect the other one. The transition zone between a stream and its adjacent aquifer referred to as the hyporheic zone plays a critical role in governing contaminant exchange and transformation during water exchange between the two water bodies. The hyporheic zone of Zenne River ( the main receptor ) is further complicated due to the fact that the river banks are artificially trained with sheet piles along its reach extending some 12 m below the surface. This study demonstrates the use of MODFLOW, a widely used modular three-dimensional block-centred finite difference, saturated flow model for simulating the flow and direction of movement of groundwater through aquifer and stream-aquifer interaction and the use of transport model RT3D, a three-dimensional multi-species reactive transport model

  5. Calibration and verification of surface contamination meters --- Procedures and techniques

    International Nuclear Information System (INIS)

    Schuler, C; Butterweck, G.; Wernli, C.; Bochud, F.; Valley, J.-F.

    2007-03-01

    A standardised measurement procedure for surface contamination meters (SCM) is presented. The procedure aims at rendering surface contamination measurements to be simply and safely interpretable. Essential for the approach is the introduction and common use of the radionuclide specific quantity 'guideline value' specified in the Swiss Radiation Protection Ordinance as unit for the measurement of surface activity. The according radionuclide specific 'guideline value count rate' can be summarized as verification reference value for a group of radionuclides ('basis guideline value count rate'). The concept can be generalized for SCM of the same type or for SCM of different types using he same principle of detection. A SCM multi source calibration technique is applied for the determination of the instrument efficiency. Four different electron radiation energy regions, four different photon radiation energy regions and an alpha radiation energy region are represented by a set of calibration sources built according to ISO standard 8769-2. A guideline value count rate representing the activity per unit area of a surface contamination of one guideline value can be calculated for any radionuclide using instrument efficiency, radionuclide decay data, contamination source efficiency, guideline value averaging area (100 cm 2 ), and radionuclide specific guideline value. n this way, instrument responses for the evaluation of surface contaminations are obtained for radionuclides without available calibration sources as well as for short-Iived radionuclides, for which the continuous replacement of certified calibration sources can lead to unreasonable costs. SCM verification is based on surface emission rates of reference sources with an active area of 100 cm 2 . The verification for a given list of radionuclides is based on the radionuclide specific quantity guideline value count rate. Guideline value count rates for groups of radionuclides can be represented within the maximum

  6. Removal of Microbial Contamination from Surface by Plasma

    Science.gov (United States)

    Feng, Xinxin; Liu, Hongxia; Shen, Zhenxing; Wang, Taobo

    2018-01-01

    Microbial contamination is closely associated with human and environmental health, they can be tested on food surfaces, medical devices, packing material and so on. In this paper the removal of the microbial contamination from surface using plasma treatment is investigated. The Escherichia coli (E. coli) has been chosen as a bio-indicator enabling to evaluate the effect of plasma assisted microbial inactivation. Oxygen gas was as the working gas. The plasma RF power, plasma exposition time, gas flow and the concentration of organic pollutant were varied in order to see the effect of the plasma treatment on the Gram-negative germ removal. After the treatment, the microbial abatement was evaluated by the standard plate count method. This proved a positive effect of the plasma treatment on Gram-negative germ removal. The kinetics and mathematical model of removal were studied after plasma treatment, and then the removing course of E. coli was analyzed. This work is meaningful for deepening our understanding of the fundamental scientific principles regarding microbial contamination from surface by plasma.

  7. Explosive Contamination from Substrate Surfaces: Differences and Similarities in Contamination Techniques Using RDX and C-4

    Science.gov (United States)

    Miller, C. J.; Yoder, T. S.

    2010-06-01

    Explosive trace detection equipment has been deployed to airports for more than a decade. During this time, the need for standardized procedures and calibrated trace amounts for ensuring that the systems are operating properly and detecting the correct explosive has been apparent but a standard representative of a fingerprint has been elusive. Standards are also necessary to evaluate instrumentation in the laboratories during development and prior to deployment to determine sample throughput, probability of detection, false positive/negative rates, ease of use by operator, mechanical and/or software problems that may be encountered, and other pertinent parameters that would result in the equipment being unusable during field operations. Since many laboratories do not have access to nor are allowed to handle explosives, the equipment is tested using techniques aimed at simulating the actual explosives fingerprint. This laboratory study focused on examining the similarities and differences in three different surface contamination techniques that are used to performance test explosive trace detection equipment in an attempt to determine how effective the techniques are at replicating actual field samples and to offer scenarios where each contamination technique is applicable. The three techniques used were dry transfer deposition of standard solutions using the Transportation Security Laboratory’s (TSL) patented dry transfer techniques (US patent 6470730), direct deposition of explosive standards onto substrates, and fingerprinting of actual explosives onto substrates. RDX was deposited on the surface of one of five substrates using one of the three different deposition techniques. The process was repeated for each substrate type using each contamination technique. The substrate types used were: 50% cotton/50% polyester as found in T-shirts, 100% cotton with a smooth surface such as that found in a cotton dress shirt, 100% cotton on a rough surface such as that

  8. Experimental study on source efficiencies for estimating surface contamination level

    International Nuclear Information System (INIS)

    Ichiji, Takeshi; Ogino, Haruyuki

    2008-01-01

    Source efficiency was measured experimentally for various materials, such as metals, nonmetals, flooring materials, sheet materials and other materials, contaminated by alpha and beta emitter radioactive nuclides. Five nuclides, 147 Pm, 60 Co, 137 Cs, 204 Tl and 90 Sr- 90 Y, were used as the beta emitters, and one nuclide 241 Am was used as the alpha emitter. The test samples were prepared by placing drops of the radioactive standardized solutions uniformly on the various materials using an automatic quantitative dispenser system from Musashi Engineering, Inc. After placing drops of the radioactive standardized solutions, the test materials were allowed to dry for more than 12 hours in a draft chamber with a hood. The radioactivity of each test material was about 30 Bq. Beta rays or alpha rays from the test materials were measured with a 2-pi gas flow proportional counter from Aloka Co., Ltd. The source efficiencies of the metals, nonmetals and sheet materials were higher than 0.5 in the case of contamination by the 137 Cs, 204 Tl and 90 Sr- 90 Y radioactive standardized solutions, higher than 0.4 in the case of contamination by the 60 Co radioactive standardized solution, and higher than 0.25 in the case of contamination by the alpha emitter the 241 Am radioactive standardized solution. These values were higher than those given in Japanese Industrial Standards (JIS) documents. In contrast, the source efficiencies of some permeable materials were lower than those given in JIS documents, because source efficiency varies depending on whether the materials or radioactive sources are wet or dry. This study provides basic data on source efficiency, which is useful for estimating the surface contamination level of materials. (author)

  9. Nickel in tap water

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, K E; Nielsen, G D; Flyvholm, M A; Fregert, S; Gruvberge, B

    1983-03-01

    Nickel analyses of tap water from several sources in Copenhagen gave up to 490 X 10(-6) g X 1(-1) in the first 250 ml portions. Hot water gave higher values than cold water. After flushing for 5 min, low values were found. Considerable variation from time to time and from tap to tap was found. Drinking of only the first portion in the morning might have an influence on nickel hand eczema.

  10. Bacteria contamination of touch surfaces in Polish hospital wards

    Directory of Open Access Journals (Sweden)

    Anna Różańska

    2017-08-01

    Full Text Available Background: The objective of the study has been to evaluate the pathogenic bacteria contamination of touch surfaces in hospital wards. Material and Methods: Samples were taken from frequently touched surfaces in the hospital environment in 13 units of various types. Culturing was carried out on solid blood agar and in growth broth (tryptic soy broth – TSB. Species identification was performed using the analytical profile index (API biochemical testing and confirmed with matrix assisted laser desorption ionization time-flight mass spectrometry (MALDI-TOF-MS system. Results: The total of 161 samples were taken for the study. Fifty-two of them, after 24 h of culture on a solid medium, demonstrated bacterial growth and further 60 samples had growth after prior multiplication in TSB. Overall, 69.6% of samples exhibited growth of 19 bacterial species. Pathogenic species – representing indicator organisms of efficiency of hospital cleaning – was demonstrated by 21.4% of samples. Among them Acinetobacter spp., Enterocococci spp. and Staphylococcus aureus were identified. Coagulase-negative staphylococci (CNS were predominant. The proportion of various groups of bacteria significantly varied in respective hospitals, and in various types of wards. Disturbing observation is a large proportion of resistance of isolated CNS strains as a potential reservoir of resistance genes. Conclusions: The results show that touch surfaces in hospital units are contaminated by both potentially pathogenic and pathogenic bacterial species. In connection with the reported, also in Poland, frequent omission or incorrect execution of hand hygiene by hospital staff, and probably patients, touch surfaces still constitute important reservoir of pathogenic bacteria. Improving hand hygiene compliance of health-care workers with recommendations is necessary for increasing biological safety of hospital environment. Med Pr 2017;68(3:459–467

  11. Recommendations for determining the surface contamination of the skin and estimating radiation exposure of the skin after contamination

    International Nuclear Information System (INIS)

    1989-01-01

    The recommendations are applicable to the determination of surface contaminations of the skin and to the estimation of the expected radiation exposure of the skin of contaminated persons. According to the present recommendations, the radiation exposure can only be estimated for the intact and healthy skin

  12. Tapping with intentional drift

    NARCIS (Netherlands)

    Vardy, A.N.; Daffertshofer, A.; Beek, P.J.

    2009-01-01

    When tapping a desired frequency, subjects tend to drift away from this target frequency. This compromises the estimate of the correlation between inter-tap intervals (ITIs) as predicted by the two-level model of Wing and Kristofferson which consists of an internal timer ('clock') and motor delays.

  13. TAPS for Pupils

    Science.gov (United States)

    Earle, Sarah

    2018-01-01

    By placing the Focused Assessment approach within the TAPS pyramid framework, schools are beginning to find a number of ways in which learning in science can be enhanced for pupils. The quotations in this article provide examples of the ways in which science subject leaders (SSL) describe the impact of TAPS on their pupils.

  14. Effect of Surface Contaminants Remained on the Blasted Surface on Epoxy Coating Performance and Corrosion Resistance

    International Nuclear Information System (INIS)

    Baek, Kwang Ki; Park, Chung Seo; Kim, Ki Hong; Chung, Mong Kyu; Park, Jin Hwan

    2006-01-01

    One of the critical issues in the coating specification is the allowable limit of surface contaminant(s) - such as soluble salt(s), grit dust, and rust - after grit blasting. Yet, there is no universally accepted data supporting the relationship between the long-term coating performance and the amount of various surface contaminants allowed after grit blasting. In this study, it was attempted to prepare epoxy coatings applied on grit-blasted steel substrate dosed with controlled amount of surface contaminants - such as soluble salt(s), grit dust, and rust. Then, coating samples were subjected to 4,200 hours of cyclic test(NORSOK M-501), which were then evaluated in terms of resistance to rust creepage, blistering, chalking, rusting, cracking and adhesion strength. Additional investigations on the possible damage at the paint/steel interface were carried out using an Electrochemical Impedance Spectroscopy(EIS) and observations of under-film-corrosion. Test results suggested that the current industrial specifications were well matched with the allowable degree of rust, whereas the allowable amount of soluble salt and grit dust after grit blasting showed a certain deviation from the specifications currently employed for fabrication of marine vessels and offshore facilities

  15. Conformation evolution of oil contaminants onto aluminum oxide surface in aqueous solution: The effect of surface coverage

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Wenkun; Liu, Haitao, E-mail: xwk584523412@126.com; Sun, Yazhou; Fu, Hongya; Liang, Yingchun

    2017-01-15

    Highlights: • The dynamic conformational change of oil contaminations, at various surface coverages onto perfect α-Al{sub 2}O{sub 3}(0001) surface in aqueous solution is given. • The effect of surface coverage of oil molecules on the driving forces for the conformational change of oil contaminations is described. • The effect of interfacial water on the conformational change and even detachment of oil contaminations is considered. - Abstract: The microscopic conformational change process of oil contaminants adhered onto perfect α-Al{sub 2}O{sub 3} (0001) surface in aqueous solution was investigated by using all-atom classic molecular dynamics simulations. The change in removal mechanism of oil contaminants induced by surface coverage (surface area per molecule) was emphatically explored. Our simulation results strongly reveal that the increase in oil surface coverage induces an evident difference in microscopic detachment processes of oil contaminants. At a low surface coverage, oil contaminants can be thoroughly detached from solid surface. The whole detachment process could be divided into multi stages, including conformational change of oil contaminants on solid surface, dynamic motion of those in bulk solution and rapid migration of those from bulk solution to air/water interface. With surface coverage increasing, water diffusion becomes the key to induce conformational change and promote the detachment of oil contaminants. When oil surface coverage exceeds a threshold value, oil contaminants also undertake an evident conformational change process exhibiting typical characteristics but an incomplete detachment process occurs. All findings of the present study are helpful for the interpretation of the removal mechanism of oil contaminants on solid surface.

  16. A consideration on internal dose evaluation and intervention based on a surface contamination concept

    International Nuclear Information System (INIS)

    Yasuda, H.

    1997-01-01

    Long-term radiation doses received by the inhabitants after the Chernobyl accident have been evaluated according to the surface contamination levels on the ground surface. The health effects have also been discussed by comparison between the surface-contaminated area and the uncontaminated control area. Selected protective measures were carried out in accordance with the contamination level of surface soil. These have been based on the 'surface contamination concept' which assumes that the radiation risk to inhabitants is proportional to the level of ground-surface contamination. The observations collected in regions around Chernobyl, however, show that the internal radiation doses to the inhabitants poorly correlate with the surface contamination level. This fact poses a question on the suitability of dose evaluations and interventions based on this concept

  17. MULTIPLE IMAGING TECHNIQUES DEMONSTRATE THE MANIPULATION OF SURFACES TO REDUCE BACTERIAL CONTAMINATION

    Science.gov (United States)

    Surface imaging techniques were combined to determine appropriate manipulation of technologically important surfaces for commercial applications. Stainless steel surfaces were engineered to reduce bacterial contamination, biofilm formation, and corrosion during product processing...

  18. Natural Contamination and Surface Flashover on Silicone Rubber Surface under Haze–Fog Environment

    Directory of Open Access Journals (Sweden)

    Ang Ren

    2017-10-01

    Full Text Available Anti-pollution flashover of insulator is important for power systems. In recent years, haze-fog weather occurs frequently, which makes discharge occurs easily on the insulator surface and accelerates insulation aging of insulator. In order to study the influence of haze-fog on the surface discharge of room temperature vulcanized silicone rubber, an artificial haze-fog lab was established. Based on four consecutive years of insulator contamination accumulation and atmospheric sampling in haze-fog environment, the contamination configuration appropriate for RTV-coated surface discharge test under simulation environment of haze-fog was put forward. ANSYS Maxwell was used to analyze the influence of room temperature vulcanized silicone rubber surface attachments on electric field distribution. The changes of droplet on the polluted room temperature vulcanized silicone rubber surface and the corresponding surface flashover voltage under alternating current (AC, direct current (DC positive polar (+, and DC negative polar (− power source were recorded by a high speed camera. The results are as follows: The main ion components from haze-fog atmospheric particles are NO3−, SO42−, NH4+, and Ca2+. In haze-fog environment, both the equivalent salt deposit density (ESDD and non-soluble deposit density (NSDD of insulators are higher than that under general environment. The amount of large particles on the AC transmission line is greater than that of the DC transmission line. The influence of DC polarity power source on the distribution of contamination particle size is not significant. After the deposition of haze-fog, the local conductivity of the room temperature vulcanized silicone rubber surface increased, which caused the flashover voltage reduce. Discharge is liable to occur at the triple junction point of droplet, air, and room temperature vulcanized silicone rubber surface. After the deformation or movement of droplets, a new triple junction

  19. Wind effected redistribution of surface contamination. Progress report, September 1974--August 1975

    International Nuclear Information System (INIS)

    Amato, A.J.

    1975-01-01

    Theoretical resuspension ratios were computed through the extension of a one-dimensional model used to simulate the wind effected movement of surface contaminants. The surface movement of contamination associated with inhalable size particles was considered in relation to time, space, wind velocity, distance from the source, soil resuspension ratios, and other variables. A computer program was developed to calculate the wind effected distribution of surface contaminants. (U.S.)

  20. Monitoring of Water and Contaminant Migration at the Groundwater-Surface Water Interface

    Science.gov (United States)

    2008-08-01

    seepage is occurring in a freshwater lake environment and to map the lateral extent of any subsurface contamination at the groundwater –surface water ...and Contaminant Migration at the Groundwater -Surface Water Interface August 2008 Report Documentation Page Form ApprovedOMB No. 0704-0188 Public...4. TITLE AND SUBTITLE Monitoring of Water and Contaminant Migration at the Groundwater -Surface Water Interface 5a. CONTRACT NUMBER 5b. GRANT NUMBER

  1. Surface Contamination Monitor and Survey Information Management System

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-02-01

    Shonka Research Associates, Inc.`s (SRA) Surface Contamination Monitor and Survey Information management System (SCM/SIMS) is designed to perform alpha and beta radiation surveys of floors and surfaces and document the measured data. The SRA-SCM/SIMS technology can be applied to routine operational surveys, characterization surveys, and free release and site closure surveys. Any large nuclear site can make use of this technology. This report describes a demonstration of the SRA-SCM/SIMS technology. This demonstration is part of the chicago Pile-5 (CP-5) Large-Scale Demonstration Project (LSDP) sponsored by the US Department of Energy (DOE), Office of Science and Technology (ST), Deactivation and Decommissioning Focus Area (DDFA). The objective of the LSDP is to select and demonstrate potentially beneficial technologies at the Argonne National Laboratory-East`s (ANL) CP-5 Research Reactor Facility. The purpose of the LSDP is to demonstrate that by using innovative and improved deactivation and decommissioning (D and D) technologies from various sources, significant benefits can be achieved when compared to baseline D and D technologies.

  2. Development of apparatus for surveying uranium surface contamination quantity

    International Nuclear Information System (INIS)

    Wang Qingheng; Han Jingquan

    1994-11-01

    An apparatus for measuring uranium contamination of the surface of reactor plate component is described. The searching unit of the apparatus is a large surface multi-wire proportional counter. The cathode of the counter is made of stainless steel with low radioactive background, the window is made of film which is plated with aluminum about 6 μm; and the anode is mad by gild tungsten wire of 0.025 mm diameter. The sensitive area of the counter is 1113 mm x 100 mm. It has been shown that the intrinsic radioactive background of the apparatus is 0.002 cpm/cm 2 (2 count/min). The detecting efficiency is 67% for enriched uranium source (2π solid angle). The stability is 0.84% within 24 hour (including detector, high voltage power supply, amplifier, discriminator, computer, type and display system). The lower detection limit of the apparatus is 4.6 x 10 -10 g/cm 2 (for 20% 235 U, 0.13% 234 U, 79.64% 238 U). The apparatus can present timing by a computer controlling, and it also has the following functions: displaying, automatic alarming, classifying and typing the results. (2 tabs., 7 figs.)

  3. Surface Contamination Monitor and Survey Information Management System

    International Nuclear Information System (INIS)

    1998-02-01

    Shonka Research Associates, Inc.'s (SRA) Surface Contamination Monitor and Survey Information management System (SCM/SIMS) is designed to perform alpha and beta radiation surveys of floors and surfaces and document the measured data. The SRA-SCM/SIMS technology can be applied to routine operational surveys, characterization surveys, and free release and site closure surveys. Any large nuclear site can make use of this technology. This report describes a demonstration of the SRA-SCM/SIMS technology. This demonstration is part of the chicago Pile-5 (CP-5) Large-Scale Demonstration Project (LSDP) sponsored by the US Department of Energy (DOE), Office of Science and Technology (ST), Deactivation and Decommissioning Focus Area (DDFA). The objective of the LSDP is to select and demonstrate potentially beneficial technologies at the Argonne National Laboratory-East's (ANL) CP-5 Research Reactor Facility. The purpose of the LSDP is to demonstrate that by using innovative and improved deactivation and decommissioning (D and D) technologies from various sources, significant benefits can be achieved when compared to baseline D and D technologies

  4. Technical Assistance Plan (TAP)

    Science.gov (United States)

    A Technical Assistance Plan (TAP) enables community groups to retain the services of an independent technical advisor and to provide resources for a community group to help inform other community members about site decisions.

  5. Synthesis of present methods of surface contamination detection (skin, clothes, laboratories)

    International Nuclear Information System (INIS)

    Joudrier, P.

    1983-01-01

    The signification of the term ''contamination'' is briefly recalled. To measure the levels of contamination, there are only two methods: the direct method and the indirect method. Finally, the recent improvements in the surface contamination detection field are shortly reviewed [fr

  6. Salinization and arsenic contamination of surface water in southwest Bangladesh.

    Science.gov (United States)

    Ayers, John C; George, Gregory; Fry, David; Benneyworth, Laura; Wilson, Carol; Auerbach, Leslie; Roy, Kushal; Karim, Md Rezaul; Akter, Farjana; Goodbred, Steven

    2017-09-11

    To identify the causes of salinization and arsenic contamination of surface water on an embanked island (i.e., polder) in the tidal delta plain of SW Bangladesh we collected and analyzed water samples in the dry (May) and wet (October) seasons in 2012-2013. Samples were collected from rice paddies (wet season), saltwater ponds used for brine shrimp aquaculture (dry season), freshwater ponds and tidal channels (both wet and dry season), and rainwater collectors. Continuous measurements of salinity from March 2012 to February 2013 show that tidal channel water increases from ~0.15 ppt in the wet season up to ~20 ppt in the dry season. On the polder, surface water exceeds the World Health Organization drinking water guideline of 10 μg As/L in 78% of shrimp ponds and 27% of rice paddies, raising concerns that produced shrimp and rice could have unsafe levels of As. Drinking water sources also often have unsafe As levels, with 83% of tubewell and 43% of freshwater pond samples having >10 μg As/L. Water compositions and field observations are consistent with shrimp pond water being sourced from tidal channels during the dry season, rather than the locally saline groundwater from tubewells. Irrigation water for rice paddies is also obtained from the tidal channels, but during the wet season when surface waters are fresh. Salts become concentrated in irrigation water through evaporation, with average salinity increasing from 0.43 ppt in the tidal channel source to 0.91 ppt in the rice paddies. Our observations suggest that the practice of seasonally alternating rice and shrimp farming in a field has a negligible effect on rice paddy water salinity. Also, shrimp ponds do not significantly affect the salinity of adjacent surface water bodies or subjacent groundwater because impermeable shallow surface deposits of silt and clay mostly isolate surface water bodies from each other and from the shallow groundwater aquifer. Bivariate plots of conservative element

  7. Bioremediation of contaminated surface water by immobilized Micrococcus roseus.

    Science.gov (United States)

    Li, H; Li, P; Hua, T; Zhang, Y; Xiong, X; Gong, Z

    2005-08-01

    The problems caused by contaminated surface water have gradually become more serious in recent years. Although various remediation technologies were investigated, unfortunately, no efficient method was developed. In this paper, a new bioremediation technology was studied using Micrococcus roseus, which was immobilized in porous spherical beads by an improved polyvinyl alcohol (PVA) - sodium alginate (SA) embedding method. The experimental results indicated that COD removal rate could reach 64.7 % within 72 hours when immobilized M. roseus beads were used, which was ten times as high as that of free cells. The optimum inoculation rate of immobilized M. roseus beads was 10 % (mass percent of the beads in water sample, g g(-1)). Suitable aeration was proved necessary to enhance the bioremediation process. The immobilized cells had an excellent tolerance to pH and temperature changes, and were also more resistant to heavy metal stress compared with free cells. The immobilized M. roseus beads had an excellent regeneration capacity and could be reused after 180-day continuous usage. The Scanning Electronic Microscope (SEM) analysis showed that the bead microstructure was suitable for M. roseus growth, however, some defect structures should still be improved.

  8. Assessment of Surface Water Contamination from Coalbed Methane Fracturing-Derived Volatile Contaminants in Sullivan County, Indiana, USA.

    Science.gov (United States)

    Meszaros, Nicholas; Subedi, Bikram; Stamets, Tristan; Shifa, Naima

    2017-09-01

    There is a growing concern over the contamination of surface water and the associated environmental and public health consequences from the recent proliferation of hydraulic fracturing in the USA. Petroleum hydrocarbon-derived contaminants of concern [benzene, toluene, ethylbenzene, and xylenes (BTEX)] and various dissolved cations and anions were spatially determined in surface waters around 15 coalbed methane fracking wells in Sullivan County, IN, USA. At least one BTEX compound was detected in 69% of sampling sites (n = 13) and 23% of sampling sites were found to be contaminated with all of the BTEX compounds. Toluene was the most common BTEX compound detected across all sampling sites, both upstream and downstream from coalbed methane fracking wells. The average concentration of toluene at a reservoir and its outlet nearby the fracking wells was ~2× higher than other downstream sites. However, one of the upstream sites was found to be contaminated with BTEX at similar concentrations as in a reservoir site nearby the fracking well. Calcium (~60 ppm) and sulfates (~175 ppm) were the dominant cations and anions, respectively, in surface water around the fracking sites. This study represents the first report of BTEX contamination in surface water from coalbed methane hydraulic fracturing wells.

  9. 10 CFR Appendix D to Part 835 - Surface Contamination Values

    Science.gov (United States)

    2010-01-01

    ... posting of contamination and high contamination areas in accordance with § 835.603(e) and (f) and...-228, Th-230, Th-228, Pa-231, Ac-227, I-125, I-129 20 500 Th-nat, Th-232, Sr-90, Ra-223, Ra-224, U-232... pressure, and then assessing the amount of radioactive material on the swipe with an appropriate instrument...

  10. Characterization of surface water contaminants in the Clinch River and Poplar Creek

    International Nuclear Information System (INIS)

    Ford, C.; Madix, S.; Rash, C.

    1995-01-01

    Surface waters in the Clinch River and Poplar Creek have been contaminated by activities on the DOE's Oak Ridge Reservation throughout the more than 50 year history of Oak Ridge. Though the Clinch River and Poplar Creek drainage areas are contaminated with heavy metals, organics and radionuclides, public access to these sites is not restricted. The investigation, divided into discrete studies, was tailored to provide a statistically sound picture of contaminants and aqueous toxicity in Poplar Creek, investigate contaminant remobilization from sediments, and determine contaminant levels during a series of ''worst-case'' events. Results for Poplar Creek indicate that average contaminant values were below levels of concern for human health and ecological risk, though contaminant distributions suggest that episodic events contribute sufficiently to system contaminant levels to be of concern. Additionally, water column contaminant levels were significantly higher in particle deposition areas rather than at known contaminant sources. Levels of organic compounds in reference areas to Poplar Creek exceeded those in the Poplar Creek study area. In the Clinch River and Poplar Creek, statistical differences in metal and radionuclide levels from known contaminated areas confirmed previous results, and were used to independently distinguish between sites. Contaminant concentrations were elevated in association with sediments, though no distinction between deposition and remobilization could be made. Due to elevated contaminant levels, and some unexpected contaminant distributions, sites in Poplar Creek and off-channel embayments of the Clinch River were identified that will require additional characterization

  11. Materials SIG quantification and characterization of surface contaminants

    Science.gov (United States)

    Crutcher, E. Russ

    1992-01-01

    When LDEF entered orbit its cleanliness was approximately a MIL-STD-1246B Level 2000C. Its burden of contaminants included particles from every part of its history including a relatively small contribution from the shuttle bay itself. Although this satellite was far from what is normally considered clean in the aerospace industry, contaminating events in orbit and from processing after recovery were easily detected. The molecular contaminants carried into orbit were dwarfed by the heavy deposition of UV polymerized films from outgassing urethane paints and silicone based materials. Impacts by relatively small objects in orbit could create particulate contaminants that easily dominated the particle counts within a centimeter of the impact site. During the recovery activities LDEF was 'sprayed' with a liquid high in organics and water soluble salts. With reentry turbulence, vibration, and gravitational loading particulate contaminants were redistributed about LDEF and the shuttle bay.

  12. Radioactive contamination of some rubber or plastic surfaces by fission products. Decontamination tests

    International Nuclear Information System (INIS)

    Mestre, E.; Sautiez, N.

    1957-10-01

    With the objective of notably addressing the contamination and decontamination of gloves and floor covering, this report first presents some characteristics of contaminating radioactive materials (nature, physical and chemical condition), of contaminated surfaces (surface condition, surface nature), and of decontamination processes (physical, chemical or mechanical action). It describes the operational modality implemented to test decontamination processes on various glove or flooring materials: sample preparation, counting, decontamination, reproducibility of decontamination tests, results in terms of activity reduction. It more precisely describes the tested samples: short gloves, gloves from glove boxes, floor and wall coverings. Results are presented and discussed in terms of sample susceptibility to contamination, and of decontamination, but also for re-contamination tests after a Nab-based decontamination (susceptibility to contamination, decontamination gain)

  13. Ion implanters contamination on wafer surface analyzed by ToF-SIMS and SPV analytical techniques

    International Nuclear Information System (INIS)

    Ricciari, R.; Bertini, M.; Ferlito, E.P.; Pizzo, G.; Anastasi, G.; Mello, D.; Franco, G.

    2007-01-01

    In ULSI processes, metallic contamination controls are very important issues. For the ion implantation process it is known that several sources of contaminations still need to be controlled: metals from sputtering of the apertures or wafer holders, Na + contaminations from filament impurities and messy maintenance procedure. ToF-SIMS is one of the most promising candidates to perform in-line surface analysis due to its high sensitivity. It is very common to use surface photo-voltage (SPV) techniques to control ion implanter equipments but this kind of analysis is an indirect measure for metallic contamination. The aim of this work is to study the possibility to use ToF-SIMS instead of SPV for in line equipment contamination monitoring. For this reason a comparison between SPV and ToF-SIMS data occurred. Good correlation between the data is shown; moreover ToF-SIMS spectra give detailed information about the other contaminations present on the wafer surface

  14. Assessment of surface contamination level in an operating uranium ore processing facility of Jaduguda, India

    International Nuclear Information System (INIS)

    Meena, J.S.; Patnaik, R.L.; Jha, V.N.; Sahoo, S.K.; Ravi, P.M.; Tripathi, R.M.

    2014-01-01

    Radiological concern of the occupational workers and the area is given priority over other safety issue in confirmation with the stipulated guideline of national regulatory agency (AERB/FEFCF/SG-2, 2007). The key concern from the radiological hazard evaluation point of view is air activity, external gamma level and surface contamination. Present investigations was carried out to ascertain the surface contamination level of uranium ore processing facility at Jaduguda, Jharkhand. For a low grade uranium ore processing industry surface contamination is a major concern in product precipitation and recovery section. In view of this, the ore processing plant can broadly be classified into three areas i.e. ion exchange area, precipitation and product recovery section and other areas. The monitoring results incorporate the level of surface contamination of the plant during the last five years. The geometric mean activity of surface contamination level was 31.1, 34.5 and 9.8 Bq dm -2 in ion exchange, product precipitation and recovery and other areas with GSD of 2, 2.5 and 1.9. In most of the cases the surface contamination level was well within the recommended limit of 100 Bq dm -2 for M class uranium compound. Occasional cases of surface contamination levels exceeding the recommended limit were addressed and areas were decontaminated. Based on the study, modification in the design feature of the surface of the finished product section was also suggested so that the decontamination procedure can be more effectively implemented

  15. Surface soil contamination standards for Rockwell Hanford Operations

    International Nuclear Information System (INIS)

    Boothe, G.F.

    1981-01-01

    The 200 Areas of the Hanford site contain soils contaminated with levels of radioactivity ranging from fallout concentrations to levels requiring radiological controls. Some contamination is more or less uniformly distributed, and some occurs as discrete specks or spots of activity. Because of the acute need for standards, the Rockwell Environmental Protection (EP) Group proceeded to develop standards; these were approved by Rockwell in October 1979. It must be emphasized that these standards are only applicable to the 200 Areas of the Hanford site or other areas under Rockwell's jurisdiction. It is assumed that access to these areas will always be restricted and that land-use restrictions will be maintained. Contamination limits for areas used by the general public would normally be lower than the limits derived in this case. It appears that the Rockwell standards divided by a factor of 5 to 10 may be reasonable contamination guidelines for the general environment

  16. Propeller TAP flap

    DEFF Research Database (Denmark)

    Thomsen, Jørn Bo; Bille, Camilla; Wamberg, Peter

    2013-01-01

    major complications needing additional surgery. One flap was lost due to a vascular problem. Breast reconstruction can be performed by a propeller TAP flap without cutting the descending branch of the thoracodorsal vessels. However, the authors would recommend that a small cuff of muscle is left around...

  17. Surface contamination to UV-curable acrylates in the furniture and parquet industry.

    Science.gov (United States)

    Surakka, J; Lindh, T; Rosén, G; Fischer, T

    2001-03-01

    Surface contamination to ultraviolet radiation curable coatings (UV coatings), used increasingly in the parquet and furniture industry, is a matter of concern as a source for skin contamination. UV coatings contain chemically and biologically reactive acrylates, well known as skin contact irritants and sensitizers. Surface contamination may spread secondarily to equipment and other unexpected areas even outside the workplace. Yet, studies concerning this type of contamination are lacking due to lack of suitable sampling methods. Surface contamination of the work environment with risk for skin exposure to UV coating was measured employing a quantitative adhesive tape sampling method developed for this purpose. A pilot study was first performed at three workplaces to evaluate the contamination. In the main study, we wanted to locate and identify in detail the surface contamination of areas where problems exist, and to determine the extent of the problem. Measurements were performed at seven workplaces on two separate workdays (round 1 and 2) within a six-month period. Samples were collected from the workplaces based on the video monitoring of skin contact frequency with the surfaces and categorized into three groups to analyze risk. The pilot study indicated that surface contamination to TPGDA containing UV coatings was common, found in 76 percent of the surfaces, and varied with a maximum of 909 microg TPGDA 10 cm(-2) sampling area. In the main study TPGDA was found in 153 out of 196 collected samples (78.1%); for round one 78.1 percent (82 out of 105 samples) and for round two 78.0 percent (71 out of 91 samples). The average TPGDA mass on positive surface samples was on the first round 2,247 +/- 7,462 microg, and on the second round 2,960 +/- 4,590 microg. We conclude that surface contamination to uncured UV coatings at UV-curing lines is common and this involves a risk for harmful, unintentional skin exposure to acrylates.

  18. Vegetated Treatment Systems for Removing Contaminants Associated with Surface Water Toxicity in Agriculture and Urban Runoff.

    Science.gov (United States)

    Anderson, Brian S; Phillips, Bryn M; Voorhees, Jennifer P; Cahn, Michael

    2017-05-15

    Urban stormwater and agriculture irrigation runoff contain a complex mixture of contaminants that are often toxic to adjacent receiving waters. Runoff may be treated with simple systems designed to promote sorption of contaminants to vegetation and soils and promote infiltration. Two example systems are described: a bioswale treatment system for urban stormwater treatment, and a vegetated drainage ditch for treating agriculture irrigation runoff. Both have similar attributes that reduce contaminant loading in runoff: vegetation that results in sorption of the contaminants to the soil and plant surfaces, and water infiltration. These systems may also include the integration of granulated activated carbon as a polishing step to remove residual contaminants. Implementation of these systems in agriculture and urban watersheds requires system monitoring to verify treatment efficacy. This includes chemical monitoring for specific contaminants responsible for toxicity. The current paper emphasizes monitoring of current use pesticides since these are responsible for surface water toxicity to aquatic invertebrates.

  19. Contaminant interferences with SIMS analyses of microparticle impactor residues on LDEF surfaces

    International Nuclear Information System (INIS)

    Simon, C.G.; Batchelor, D.; Griffis, D.P.; Hunter, J.L.; Misra, V.; Ricks, D.A.; Wortman, J.J.

    1992-01-01

    Elemental analyses of impactor residues on high purity surface exposed to the low earth orbit (LEO) environment for 5.8 years on Long Duration Exposure Facility (LDEF) has revealed several probable sources for microparticles at this altitude, including natural micrometeorites and manmade debris ranging from paint pigments to bits of stainless steel. A myriad of contamination interferences were identified and their effects on impactor debris identification mitigated during the course of this study. These interferences included pre-, post-, and in-flight deposited particulate surface contaminants, as well as indigenous heterogeneous material contaminants. Non-flight contaminants traced to human origins, including spittle and skin oils, contributed significant levels of alkali-rich carbonaceous interferences. A ubiquitous layer of in-flight deposited silicaceous contamination varied in thickness with location on LDEF and proximity to active electrical fields. In-flight deposited (low velocity) contaminants included urine droplets and bits of metal film from eroded thermal blankets

  20. Concrete decontamination: two innovative processes in response to surface or deep contamination

    International Nuclear Information System (INIS)

    CUER, F.; Nadai, A. de; Faure, S.

    2008-01-01

    To meet the future needs in the nuclear industry as regards dismantling and decommissioning, the LPAD (Laboratoire des Procedes Avances de Decontamination) develops new specific techniques to decontaminate concretes: the drying gel process adapted to surface contamination and the electrokinetics process to treat deep contamination. Indeed, because the concrete constitute a porous medium, two types of contamination can be met according to the environment to which is subjected the material. In the case of an accidental or dry contamination, radio elements do not penetrate beyond the first millimeters of the material. The contamination is then considered as surface. On the contrary, the contamination is considered as 'deep' when radioactive ions have diffused deeply under the effects of the natural diffusion. This is the case in fuel storage pond or other many nuclear infrastructures. (authors)

  1. Plastic deformation to enhance plasma-assisted nitriding: On surface contamination induced by Surface Mechanical Attrition Treatment

    International Nuclear Information System (INIS)

    Samih, Youssef; Novelli, Marc; Bolle, Bernard; Allain, Nathalie; Fundenberger, Jean-Jacques; Marcos, Grégory; Czerwiec, Thierry; Grosdidier, Thierry; Thiriet, Tony

    2014-01-01

    The Surface Mechanical Attrition Treatment is a recent technique leading to the formation of nanostructured layers by the repeated action of impacting balls. While several communications have revealed possible contamination of the SMATed surfaces, the nature of this surface contamination was analyzed in the present contribution for the treatment of an AISI 316L stainless steel. It is shown, by a combination of Transmission Electron Microscopy and Glow Discharge – Optical Emission Spectrometry, that the surface was alloyed with Ti, Al and V coming from the sonotrode that is used to move the balls as well as Zr coming from the zirshot® balls themselves

  2. Plastic deformation to enhance plasma-assisted nitriding: On surface contamination induced by Surface Mechanical Attrition Treatment

    Science.gov (United States)

    Samih, Youssef; Novelli, Marc; Thiriet, Tony; Bolle, Bernard; Allain, Nathalie; Fundenberger, Jean-Jacques; Marcos, Grégory; Czerwiec, Thierry; Grosdidier, Thierry

    2014-08-01

    The Surface Mechanical Attrition Treatment is a recent technique leading to the formation of nanostructured layers by the repeated action of impacting balls. While several communications have revealed possible contamination of the SMATed surfaces, the nature of this surface contamination was analyzed in the present contribution for the treatment of an AISI 316L stainless steel. It is shown, by a combination of Transmission Electron Microscopy and Glow Discharge - Optical Emission Spectrometry, that the surface was alloyed with Ti, Al and V coming from the sonotrode that is used to move the balls as well as Zr coming from the zirshot® balls themselves.

  3. Development of portable and automatic smear sampler for measuring surface contamination

    International Nuclear Information System (INIS)

    Lee, Bong Jae; Chang, S. Y.; Kim, B. H.; Kim, J. S.; Lee, H. S.; Kim, C. K.; Swol, C. W.

    2000-12-01

    In measuring radioactive contamination in radiation controlled area of nuclear facility, the technical criteria to evaluate surface contamination level and to sample by indirect method was established in this paper. Radioactive materials always present on surface within operating nuclear facilities. Because of the presence of interfering radiation field, health physicists take smear samples to monitoring surface contamination according to routine monitoring program. But there are some problems like great errors and difference of personnel. Then, to solve them, The portable and automatic smear sampling apparatus was designed and fabricated

  4. Development of portable and automatic smear sampler for measuring surface contamination

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Bong Jae; Chang, S. Y.; Kim, B. H.; Kim, J. S.; Lee, H. S.; Kim, C. K.; Swol, C. W

    2000-12-01

    In measuring radioactive contamination in radiation controlled area of nuclear facility, the technical criteria to evaluate surface contamination level and to sample by indirect method was established in this paper. Radioactive materials always present on surface within operating nuclear facilities. Because of the presence of interfering radiation field, health physicists take smear samples to monitoring surface contamination according to routine monitoring program. But there are some problems like great errors and difference of personnel. Then, to solve them, The portable and automatic smear sampling apparatus was designed and fabricated.

  5. Levels of surface contamination with radioactive materials at workplaces of nuclear research centre at Rez

    International Nuclear Information System (INIS)

    Hoelgye, Z.; Nemcova, I.; Kasikova, M.; Popper, J.; Chysky, J.

    1983-01-01

    A hygiene supervision unit at workplaces of the nuclear Research Institute in Rez monitored on a long-term basis surface contamination with radioactive substances. Surface contamination was found at workplaces with open sources. Of the 4343 monitored places action levels were only exceeded in 13 cases. The obtained data were used for typifying workplaces with the highest level of surface contamination, to determine in certain instances the mechanism of the escape of radioactive substances from insulating facilities and to determine the rate of the spread of the radioactive substance into adjacent non-active workplaces. (author)

  6. A criterion of contamination of the glass surface of photovoltaic batteries

    International Nuclear Information System (INIS)

    Tursunov, M.N.; Dyskin, V.G.; Yuldashev, I.A. et al.; Park Jeong Hwoan

    2015-01-01

    The relative change in the coefficient of efficiency is chosen as a criterion for contamination of the glass surface of a photovoltaic battery. Using the formula obtained, the results of measurements of the transmission coefficient of a contaminated glass plate after its exposure to open air in the center of Tashkent for 80 and 110 days are processed. It is shown that the contamination of the glass plate reduces the coefficient of efficiency of the PVB by 50.0%. (authors)

  7. Microbial contaminants isolated from items and work surfaces in the post- operative ward at Kawolo general hospital, Uganda.

    Science.gov (United States)

    Sserwadda, Ivan; Lukenge, Mathew; Mwambi, Bashir; Mboowa, Gerald; Walusimbi, Apollo; Segujja, Farouk

    2018-02-06

    Nosocomial infections are a major setback in the healthcare delivery system especially in developing countries due to the limited resources. The roles played by medical care equipment and work surfaces in the transmission of such organisms have inevitably contributed to the elevated mortality, morbidity and antibiotic resistances. A total 138 samples were collected during the study from Kawolo general hospital. Swab samples were collected from various work surfaces and fomites which consisted of; beds, sink taps, infusion stands, switches, work tables and scissors. Cultures were done and the susceptibility patterns of the isolates were determined using Kirby Bauer disc diffusion method. Data was analyzed using Stata 13 and Microsoft Excel 2013 packages. A total of 44.2% (61/138) of the collected swab specimens represented the overall bacterial contamination of the sampled articles. Staphylococcus aureus and Klebsiella pneumoniae accounted for the highest bacterial contaminants constituting of 75.4% (46/61) and 11.5% (7/61) respectively. Infusion stands and patient beds were found to have the highest bacterial contamination levels both constituting 19.67% (12/61). The highest degree of transmission of organisms to patients was found to be statistically significant for patient beds with OR: 20.1 and P-value 8X10 - 4 . Vancomycin, ceftriaxone and ciprofloxacin were the most effective antibiotics with 100%, 80% and 80% sensitivity patterns among the isolates respectively. Multi-drug resistant (MDR) Staphylococcus aureus accounted for 52% (24/46) with 4% (1/24) classified as a possible extensively drug resistant (XDR) whereas Gram negative isolates had 27% (4/15) MDR strains out of which 50%(2/4) were classified as possible pan-drug resistant (PDR). The high prevalence of bacterial contaminants in the hospital work environment is an indicator of poor or ineffective decontamination. The study findings reiterate the necessity to formulate drug usage policies and re

  8. Bioremediation of hydrocarbon contaminated surface water, groundwater, and soils

    International Nuclear Information System (INIS)

    Piotrowski, M.R.

    1991-01-01

    Bioremediation is currently receiving considerable attention as a remediation option for sites contaminated with hazardous organic compounds. There is an enormous amount of interest in bioremediation, and numerous journals now publish research articles concerning some aspect of the remediation approach. A review of the literature indicates that two basic forms of bioremediation are currently being practiced: the microbiological approach and the microbial ecology approach. Each form has its advocates and detractors, and the microbiological approach is generally advocated by most of the firms that practice bioremediation. In this paper, the merits and disadvantages of these forms are reviewed and a conceptual approach is presented for assessing which form may be most useful for a particular contaminant situation. I conclude that the microbial ecology form of bioremediation may be the most useful for the majority of contaminant situations, and I will present two case histories in support of this hypothesis

  9. Laboratory Studies on Surface Sampling of Bacillus anthracis Contamination: Summary, Gaps, and Recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F.; Amidan, Brett G.; Hu, Rebecca

    2011-11-28

    This report summarizes previous laboratory studies to characterize the performance of methods for collecting, storing/transporting, processing, and analyzing samples from surfaces contaminated by Bacillus anthracis or related surrogates. The focus is on plate culture and count estimates of surface contamination for swab, wipe, and vacuum samples of porous and nonporous surfaces. Summaries of the previous studies and their results were assessed to identify gaps in information needed as inputs to calculate key parameters critical to risk management in biothreat incidents. One key parameter is the number of samples needed to make characterization or clearance decisions with specified statistical confidence. Other key parameters include the ability to calculate, following contamination incidents, the (1) estimates of Bacillus anthracis contamination, as well as the bias and uncertainties in the estimates, and (2) confidence in characterization and clearance decisions for contaminated or decontaminated buildings. Gaps in knowledge and understanding identified during the summary of the studies are discussed and recommendations are given for future studies.

  10. Exploring Surface Analysis Techniques for the Detection of Molecular Contaminants on Spacecraft

    Science.gov (United States)

    Rutherford, Gugu N.; Seasly, Elaine; Thornblom, Mark; Baughman, James

    2016-01-01

    Molecular contamination is a known area of concern for spacecraft. To mitigate this risk, projects involving space flight hardware set requirements in a contamination control plan that establishes an allocation budget for the exposure of non-volatile residues (NVR) onto critical surfaces. The purpose of this work will focus on non-contact surface analysis and in situ monitoring to mitigate molecular contamination on space flight hardware. By using Scanning Electron Microscopy and Energy Dispersive Spectroscopy (SEM-EDS) with Raman Spectroscopy, an unlikely contaminant was identified on space flight hardware. Using traditional and surface analysis methods provided the broader view of the contamination sources allowing for best fit solutions to prevent any future exposure.

  11. Conformational change of oil contaminants adhered onto crystalline alpha-alumina surface in aqueous solution

    International Nuclear Information System (INIS)

    Xie, Wenkun; Sun, Yazhou; Liu, Haitao; Fu, Hongya; Liang, Yingchun

    2016-01-01

    Graphical abstract: - Highlights: • Dynamic conformational change process of oil contaminations adhered onto Al-terminated α-Al_2O_3 surface in aqueous solution is given. • Effect of water penetration on the conformational change and even detachment of oil contaminants is considered. • Change of driving forces leading to the conformational change of oil contaminants is described. - Abstract: Microscopic conformational change of oil contaminants adhered onto perfect α-Al_2O_3 (0001) surface in the aqueous solution was simulated by means of detailed fully atomistic molecular dynamics simulations. The main driving forces of the conformation change process of the oil contaminants were explored. The simulation results indicate that with submerging of the contaminated α-Al_2O_3 (0001) surface into the aqueous solution, the oil contaminants undertake an evident conformational change process. The dynamic process can be divided into several stages, including early penetration of water molecules, formation and widening of water channel, and generation of molecularly adsorbed hydration layers. Moreover, the oil contaminants on the α-Al_2O_3 surface are not fully removed from solid surface after a 10 ns relaxation, while a relatively stable oil/water/solid three-phase interface is gradually formed. Further, the residual oil contaminants are finally divided into several new ordered molecular adsorption layers. In addition, by systemically analyzing the driving forces for the conformational change of the oil contaminants, the penetration of water molecules is found to be the most important driving force. With penetrating of the water molecules, the dominating interactions controlling the conformational change of the oil contaminants have been changing over the whole simulation.

  12. Soil contamination of plant surfaces from grazing and rainfall interactions

    International Nuclear Information System (INIS)

    Hinton, T.G.; Stoll, J.M.; Tobler, L.

    1995-01-01

    Contaminants often attach to soil particles, and their subsequent environmental transport is largely determined by processes that govern soil movement. We examined the influence of grazing intensity on soil contamination of pastures. Four different grazing densities of sheep were tested against an ungrazed control plot. Scandium concentrations were determined by neutron activation analysis and was used as a tracer of soil adhesion on vegetation. Soil loadings ( g soil kg -1 dry plant) increased 60% when grazing intensity was increased by a factor of four (p 0.003). Rain and wind removed soil from vegetation in the ungrazed control plots, but when grazing sheep were present, an increase in rain from 0.3 to 9.7 mm caused a 130% increase in soil contamination. Multiple regression was used to develop an equation that predicts soil loadings as a function of grazing density, rainfall and wind speed (p = 0.0001, r 2 = 0.78). The model predicts that if grazing management were to be used as a tool to reduce contaminant intake from inadvertent consumption of resuspended soil by grazing animals, grazing densities would have to be reduced 2.5 times to reduce soil loadings by 50%. (author)

  13. Metal Hydride assited contamination on Ru/Si surfaces

    NARCIS (Netherlands)

    Pachecka, Malgorzata; Lee, Christopher James; Sturm, Jacobus Marinus; Bijkerk, Frederik

    2013-01-01

    In extreme ultraviolet lithography (EUVL) residual tin, in the form of particles, ions, and atoms, can be deposited on nearby EUV optics. During the EUV pulse, a reactive hydrogen plasma is formed, which may be able to react with metal contaminants, creating volatile and unstable metal hydrides that

  14. Radioactive air and surface contamination in Czechia and Slovakia

    International Nuclear Information System (INIS)

    Rumyantsev, V.V.

    1992-01-01

    Data are presented on the radioactive substance effluents into the environment in conditions of NPP normal operation and on the air contamination by 85 Kr due to operation of the European and Soviet plants for reprocessing spent nuclear fuel. Data are given on the dosage of the Czechoslovakia population due to the Chernobyl NPP accident

  15. Measurement of residual radioactive surface contamination by 2-D laser heated TLD

    International Nuclear Information System (INIS)

    Jones, S.C.

    1997-06-01

    The feasibility of applying and adapting a two-dimensional laser heated thermoluminescence dosimetry system to the problem of surveying for radioactive surface contamination was studied. The system consists of a CO 2 laser-based reader and monolithic arrays of thin dosimeter elements. The arrays consist of 10,201 thermoluminescent phosphor elements of 40 micron thickness, covering a 900 cm 2 area. Array substrates are 125 micron thick polyimide sheets, enabling them to easily conform to regular surface shapes, especially for survey of surfaces that are inaccessible for standard survey instruments. The passive, integrating radiation detectors are sensitive to alpha and beta radiation at contamination levels below release guideline limits. Required contact times with potentially contaminated surfaces are under one hour to achieve detection of transuranic alpha emission at 100 dpm/100 cm 2 . Positional information obtained from array evaluation is useful for locating contamination zones. Unique capabilities of this system for survey of sites, facilities and material include measurement inside pipes and other geometrical configurations that prevent standard surveys, and below-surface measurement of alpha and beta emitters in contaminated soils. These applications imply a reduction of material that must be classified as radioactive waste by virtue of its possibility of contamination, and cost savings in soil sampling at contaminated sites

  16. Nuclear electronic components of surface contamination monitor based on multi-electrode proportional counter

    International Nuclear Information System (INIS)

    Du Xiangyang; Zhang Yong; Han Shuping; Rao Xianming; Fang Jintu

    2001-01-01

    The nuclear electronic components applying in Portal Monitor and Hands and Feet Surface Contamination Monitor were based on modern integrated circuit are introduced. The detailed points in circuit design and manufacturing technique are analyzed

  17. Effect of surface contamination on osseointegration of dental implants surrounded by circumferential bone defects.

    LENUS (Irish Health Repository)

    Mohamed, Seif

    2010-05-01

    This study was designed to evaluate the effect of surface contamination on osseointegration of dental implants surrounded by a circumferential bone defect and to compare osseointegration around Osseotite with that around Nanotite implants.

  18. National Enforcement Initiative: Preventing Animal Waste from Contaminating Surface and Ground Water

    Science.gov (United States)

    This page describes EPA's goal in preventing animal waste from contaminating surface and ground Water. It is an EPA National Enforcement Initiative. Both enforcement cases, and a map of enforcement actions are provided.

  19. Physics of Beer Tapping

    OpenAIRE

    Rodríguez-Rodríguez , Javier; Casado-Chacón , Almudena; Fuster , Daniel

    2014-01-01

    International audience; The popular bar prank known in colloquial English as beer tapping consists in hitting the top of a beer bottle with a solid object, usually another bottle, to trigger the foaming over of the former within a few seconds. Despite the trick being known for long time, to the best of our knowledge, the phenomenon still lacks scientific explanation. Although it seems natural to think that shock-induced cavitation enhances the diffusion of CO2 from the supersaturated bulk liq...

  20. Monitoring chlorination practices during operation at TAPS

    International Nuclear Information System (INIS)

    Sriraman, A.K.; Wani, B.N.; Gokhale, A.S.; Yuvaraju, B.

    1995-01-01

    Chlorination of cooling waters is aimed at the condenser surfaces to minimize the biogrowth, while the residual oxidants in the effluents are negligible. This paper describes the fulfillment of the above criteria, as observed during the monitoring of chlorination practices at Tarapur Atomic Power Station (TAPS) during 1990. (author). 4 refs., 2 tabs

  1. Combined Contamination and Space Environmental Effects on Solar Cells and Thermal Control Surfaces

    Science.gov (United States)

    Dever, Joyce A.; Bruckner, Eric J.; Scheiman, David A.; Stidham, Curtis R.

    1994-01-01

    For spacecraft in low Earth orbit (LEO), contamination can occur from thruster fuel, sputter contamination products and from products of silicone degradation. This paper describes laboratory testing in which solar cell materials and thermal control surfaces were exposed to simulated spacecraft environmental effects including contamination, atomic oxygen, ultraviolet radiation and thermal cycling. The objective of these experiments was to determine how the interaction of the natural LEO environmental effects with contaminated spacecraft surfaces impacts the performance of these materials. Optical properties of samples were measured and solar cell performance data was obtained. In general, exposure to contamination by thruster fuel resulted in degradation of solar absorptance for fused silica and various thermal control surfaces and degradation of solar cell performance. Fused silica samples which were subsequently exposed to an atomic oxygen/vacuum ultraviolet radiation environment showed reversal of this degradation. These results imply that solar cells and thermal control surfaces which are susceptible to thruster fuel contamination and which also receive atomic oxygen exposure may not undergo significant performance degradation. Materials which were exposed to only vacuum ultraviolet radiation subsequent to contamination showed slight additional degradation in solar absorptance.

  2. Methods for the calculation of derived working limits for surface contamination by low-toxicity radionuclides

    International Nuclear Information System (INIS)

    Gibson, J.A.B.; Wrixon, A.D.

    1979-01-01

    Surface contamination is often measured as an indication of the general spread of radioactive contamination in a particular place. Derived working limits, (DWLs) for surface contamination provide figures against which to assess the significance of measurements. Derived working limits for surface contamination were first established for use in the nuclear energy industry. They were designed to cope with a wide range of unspecified radionuclides and were therefore based on the assumption that the contamination was due to the presence of the most hazardous radionuclides, e.g. 90 Sr, 210 Pb, 226 Ra and 239 Pu. While this assumption may still be appropriate when the radionuclide mixture is unknown, there are now many specialized uses of particular low-toxicity radionuclides in universities, hospitals and general industry. If it is known that only a particular radionuclide is present, the general DWL can be replaced by a more specific value. The methods for calculating DWLs for some of the more commonly employed low-toxicity radionuclides are described. The exposure pathways considered are (a) external radiation of the skin and inhalation of airborne material from contaminated surfaces in active areas; (b) external irradiation of the skin and ingestion from contaminated skin. Some consideration is given to the effect of the revised dose equivalent limits in the most recent recommendations of ICRP. (author)

  3. Evaluation of surface contamination due to alpha using large area contamination monitors

    International Nuclear Information System (INIS)

    Raghavayya, M.

    1998-01-01

    Radioactive contamination at work places is evaluated routinely using either the swipe sampling technique or a contamination monitor. Commercially available alpha probes used for the purpose are usually circular and have a face diameter of 50 or 100 mm. Square faced probes are also available. A thin aluminized mylar membrane of thickness 0.45 to 0.9 mg.cm -2 is used to screen the phosphor in the alpha probe to protect it from external light. The membrane cuts off more alphas from low energy emitters than from higher energy alpha emitters. Moreover the response of the detector for alphas originating at all points under the detector face is not uniform, especially when the large area alpha monitors are used. These factors can introduce errors as high as 40% into the measurements. This paper aims to quantify these errors and describe a procedure to overcome the limitations. (author)

  4. EM Task 12 - Laser cleaning of Contaminated Painted Surfaces

    International Nuclear Information System (INIS)

    Ames A. Grisanti; Charlene R. Crocker; Robert J. Jensen

    1998-01-01

    Several techniques are available or under development for surface decontamination in nuclear facilities. Each technique has its merits; however, none of them is universally the best choice for all surface decontamination applications. Because of the multitude of factors which influence the environmental and economic aspects of selecting a surface decontamination technique, it is difficult to select the best method in a given situation; an objective basis for comparing techniques is needed. The objective of this project is to develop a software tool for use by personnel selecting a surface decontamination technique. The software will incorporate performance data for available surface decontamination techniques. The beta release of the Surface Decontamination Assistant Software has been completed and has undergone testing at the Energy and Environmental Research Center (EERC). Minor modifications to the software will be completed before the end of November 1998, and a final release of the software will be issued

  5. EM Task 12 - Laser cleaning of contaminated painted surfaces

    International Nuclear Information System (INIS)

    Grisanti, Ames A.; Crocker, Charlene R.; Jensen, Robert R.

    1999-01-01

    Several techniques are available or under development for surface decontamination in nuclear facilities. Each technique has its merits; however, none of them is universally the best choice for all surface decontamination applications. Because of the multitude of factors which influence the environmental and economic aspects of selecting a surface decontamination technique, it is difficult to select the best method in a given situation; an objective basis for comparing techniques is needed. The objective of this project was to develop a software tool for use by personnel selecting a surface decontamination technique. The software incorporates performance data for available surface decontamination techniques. The beta release version of the Surface Decontamination Assistant Software has been completed and has undergone testing at the Energy and Environmental Research Center. Minor modifications to the software were completed, and a final release version of the software is ready to be issued

  6. Development of an automatic smear sampler and evaluation of surface contamination

    International Nuclear Information System (INIS)

    Seo, B. K.; Lee, B. J.; Lee, K. W.; Park, J. H.

    2004-01-01

    The surface contamination level of a radiation-controlled area is measured periodically according to atomic energy law and connection regulations. The measurement of surface contamination by an indirect method is subject to various kinds of error depending on the sampling person and consumes much time and effort in the sampling of large nuclear facilities. In this research, an automatic smear sampler is developed to solve these problems. The developed equipment is composed of a rotating sampling part, a sample transferring part, a power supply part a control part, and vacuum part. It improved the efficiency of estimation of the surface contamination level achieved periodically in a radiation-controlled area. Using an automatic smear sampler developed in this research, it is confirmed that radioactive contaminated materials are uniformly transferred to smear paper more than any sampling method by an operator. (authors)

  7. Calculation of reasonable exemption levels for surface contamination by measuring overall gamma ray

    International Nuclear Information System (INIS)

    Ogino, Haruyuki; Hattori, Takatoshi

    2008-01-01

    The present regulation on surface contamination [Bq/cm 2 ] is determined from a simple radiological model for the most hazardous radionuclides (Pu-239 for alpha emitters and Sr-90 for beta emitters) and its extremely conservative model is applied for all other alpha and beta emitters. In this study, reasonable exemption levels for surface contamination are calculated for each radionuclide by adopting an original radiological dose evaluation method for surface contamination that can be applied in radiation safety, transport safety and waste safety. Furthermore, a new concept of judging the exemption by estimating the overall contamination [Bq] on the objects from the measurement of gamma ray has been designed and a reasonable value was derived. We conclude that the overall exemption levels obtained by gamma ray measurement can be one order smaller than those obtained by the conventional method for some radionuclides, such as Mn-54, Co-60, Nb-94, Cs-134, Cs-137, Eu-152 and Eu-154. (author)

  8. Study of surface potential contamination in radioisotope and radiopharmaceutical production facilities and alternative solutions

    International Nuclear Information System (INIS)

    Suhaedi Muhammad; Rimin Sumantri; Farida Tusafariah; Djarwanti Rahayu Pipin Soedjarwo

    2013-01-01

    Radioisotope and radiopharmaceutical production facilities that exist in their operations around the world in the form of radiological impacts of radiation exposure, contamination of surface and air contamination. Given the number of existing open source in radioisotope and radiopharmaceutical production facility, then the possibility of surface contamination in the work area is quite high. For that to protect the safety and health of both workers, the public and the environment, then the licensee must conduct an inventory of some of the potential that could result in contamination of surfaces in radioisotope and radiopharmaceutical production facilities. Several potential to cause surface contamination in radioisotope and radiopharmaceutical production facilities consist of loss of resources, the VAC system disorders, impaired production facilities, limited resources and lack of work discipline and radioactive waste handling activities. From the study of some potential, there are several alternative solutions that can be implemented by the licensee to address the contamination of the surface so as not to cause adverse radiological impacts for both radiation workers, the public or the environment. (author)

  9. Atmospheric-Pressure Plasma Cleaning of Contaminated Surfaces

    International Nuclear Information System (INIS)

    Hicks, Robert F.; Herrmann, Hans W.

    2003-01-01

    The objective of this work is to demonstrate a practical, atmospheric pressure plasma tool for the surface decontamination of radioactive waste. Decontamination of radioactive materials that have accumulated on the surfaces of equipment and structures is a challenging and costly undertaking for the US Department of Energy. Our technology shows great potential for accelerating this clean up effort

  10. Contamination of Optical Surfaces Under Irradiation by Outgassed Volatile Products

    International Nuclear Information System (INIS)

    Khasanshin, R. H.; Grigorevskiy, A. V.; Galygin, A. N.; Alexandrov, N. G.

    2009-01-01

    Deposition of outgassed products of a polymeric composite on model material surfaces being irradiated by electrons and protons with initial energies of E e = 40 keV and E p = 30 keV respectively was studied. It was shown that deposition of volatile products on model material surfaces being under ionizing radiations results in increase of organic film growth rate.

  11. Finger-tapping motion analysis in cervical myelopathy by magnetic-sensor tapping device.

    Science.gov (United States)

    Miwa, Toshitada; Hosono, Noboru; Mukai, Yoshihiro; Makino, Takahiro; Kandori, Akihiko; Fuji, Takeshi

    2013-08-01

    Case-control study. The purpose of this study is to determine finger motion of patients with cervical myelopathy during finger-tapping cycles. A major symptom of patients with compressive cervical myelopathy is finger clumsiness. Therefore, understanding finger motion is prerequisite in assessing the severity of myelopathy. The popular grip-and-release test evaluates only the number of motion cycles, which is insufficient to fully describe complex finger motion. Forty-three patients with cervical myelopathy and 41 healthy controls tapped their index fingers against their thumbs as rapidly as possible for 30 seconds and the motion was recorded by a magnetic-sensor coil attached to the nail surface. Output signals were stored in a computer, which automatically calculated tapping frequency, distance moved, ratio of opening/closing velocity and the SD of the tapping interval. The SD of the tapping interval was significantly greater and all other measures were significantly smaller in patients with cervical myelopathy, than in healthy controls. All indices significantly improved after surgical decompression of the cervical spine. Distance moved (Pearson correlation coefficient: r=0.590, Ptapping interval (r=-0.451; P=0.002) were significantly correlated with the Japanese Orthopedic Association score (neurological scale). The quantitative evaluation of finger paralysis was performed by this tapping device. Speed and regularity in repetitive motion of fingers were correlated with the severity of cervical myelopathy.

  12. Tritium contaminated surface monitoring with a solid - state device

    International Nuclear Information System (INIS)

    Culcer, Mihai; Iliescu, Mariana; Curuia, Marian; Enache, Adrian; Stefanescu, Ioan; Ducu, Catalin; Malinovschi, Viorel

    2004-01-01

    The low energy of betas makes tritium difficult to detect. However, there are several methods used in tritium detection, such as liquid scintillation and ionization chambers. Tritium on or near a surface can be also detected using proportional counters and, recently, solid state devices. The paper presents our results in the design and achievement of a surface tritium monitor using a PIN photodiode as a solid state charged particle detector to count betas emitted from the surface. That method allows continuous, real-time and non-destructively measuring of tritium. (authors)

  13. Bond strength of resin-resin interfaces contaminated with saliva and submitted to different surface treatments

    Directory of Open Access Journals (Sweden)

    Adilson Yoshio Furuse

    2007-12-01

    Full Text Available The purpose of this study was to investigate the effect of different surface treatments on shear bond strength of saliva-contaminated resin-resin interfaces. Flat resin surfaces were fabricated. In the control group, no contamination or surface treatment was performed. The resin surfaces of the experimental groups were contaminated with saliva and air-dried, and then submitted to: (G1 rinsing with water and drying; (G2 application of an adhesive system; (G3 rinsing and drying, abrasion with finishing disks, etching and application of adhesive system; (G4 rinsing and drying, etching, application of silane and adhesive system. Resin cylinders were placed over the treated surfaces. The specimens were stored in water or ethanol. Shear bond strength tests were performed and the mode of failure was evaluated. Data were submitted to two-way ANOVA and Dunnett T3 test. Contamination of resin-resin interfaces with saliva significantly reduced shear strength, especially after prolonged storage (p<0.05. Similar values to the original bond strength were obtained after abrasion and application of adhesive (G3 or etching and application of silane and adhesive (G4. If contamination occurs, a surface treatment is required to guarantee an adequate interaction between the resin increments.

  14. Assessment of leg muscle activity using toe tapping in patients with Parkinson's disease: comparison of two types of toe tapping.

    Science.gov (United States)

    Taniguchi, Seira; Peper, Ferdinand; Shimokawa, Tetsuya

    2018-05-01

    [Purpose] This study investigates two types of toe tapping, i.e., "closed," with both feet on the floor, and "open," in which the foot does not touch the ground, and evaluates their usefulness in combination with monitoring of muscle activity during toe tapping. [Subjects and Methods] The study enrolled 11 patients with Parkinson's disease (PD) and 9 controls (Controls). The tibialis anterior (TA) and gastrocnemius (GS) muscle activity during toe tapping was measured using surface electromyography. [Results] In closed tapping, the minima in GS activation with the first tap was significantly higher in patients with PD than in Controls. In open tapping, the coefficient of variation (CV) of local maxima in TA activation was significantly higher in patients with PD than in Controls. In both types of tapping, the CV of extrema in GS activities increased with disease duration, but this may be due to the long-term administration of Levodopa, which itself tends to cause excessive GS activities. [Conclusion] Closed tapping is suitable for the assessment of GS activity and can detect excessive activities, which is observed as visible movement. Open tapping, on the other hand, is suitable for assessment of TA activity.

  15. SUDOQU, a new dose-assessment methodology for radiological surface contamination.

    Science.gov (United States)

    van Dillen, Teun; van Dijk, Arjan

    2018-06-12

    A new methodology has been developed for the assessment of the annual effective dose resulting from removable and fixed radiological surface contamination. It is entitled SUDOQU (SUrface DOse QUantification) and it can for instance be used to derive criteria for surface contamination related to the import of non-food consumer goods, containers and conveyances, e.g., limiting values and operational screening levels. SUDOQU imposes mass (activity)-balance equations based on radioactive decay, removal and deposition processes in indoor and outdoor environments. This leads to time-dependent contamination levels that may be of particular importance in exposure scenarios dealing with one or a few contaminated items only (usually public exposure scenarios, therefore referred to as the 'consumer' model). Exposure scenarios with a continuous flow of freshly contaminated goods also fall within the scope of the methodology (typically occupational exposure scenarios, thus referred to as the 'worker model'). In this paper we describe SUDOQU, its applications, and its current limitations. First, we delineate the contamination issue, present the assumptions and explain the concepts. We describe the relevant removal, transfer, and deposition processes, and derive equations for the time evolution of the radiological surface-, air- and skin-contamination levels. These are then input for the subsequent evaluation of the annual effective dose with possible contributions from external gamma radiation, inhalation, secondary ingestion (indirect, from hand to mouth), skin contamination, direct ingestion and skin-contact exposure. The limiting effective surface dose is introduced for issues involving the conservatism of dose calculations. SUDOQU can be used by radiation-protection scientists/experts and policy makers in the field of e.g. emergency preparedness, trade and transport, exemption and clearance, waste management, and nuclear facilities. Several practical examples are worked

  16. Development of an automatic smear sampler and a polymer film for surface radioactive contamination assay

    International Nuclear Information System (INIS)

    Seo, B.-K.; Lee, K.-W.; Woo, Z.-H.; Jeong, K.-S.; Oh, W.-Z.; Han, M.-J.

    2004-01-01

    Measurement of the surface contamination by an indirect method is subject to the various kinds of error according to the sampling person and needs much time and effort in the sampling and assay. In this research, an automatic smear sampler is developed. It improved efficiency for assay work of surface contamination level achieved periodically in a radiation controlled area. Using an automatic smear sampler developed, it is confirmed that radioactive contaminated materials are uniformly transferred to smear paper more than any sampling method by an operator. Also, Solid scintillation proximity membranes were prepared for measuring the amount of radioactive contamination in laboratories contaminated by the low energy beta-ray emitter, such as 3 H and 14 C. Polysulfone scintillation proximity membranes were prepared by impregnating Cerium Activated Yttrium Silicate (CAYS), an inorganic fluor, in a membrane structure. The inorganic fluor-impregnated membranes were applied to detect the radioactive surface contamination. The preparation of membranes was divided into two processes. A supporting polymer film was made of casting solutions consisting of polysulfone and solvent, their cast film being solidified by vacuum evaporation. CAYS-dispersed polymer solutions were cast over the first, solidified polymer films and coagulated either by evaporating solvent in the solution with non-solvent in a coagulation bath. The prepared membranes had two distinguished, but tightly attached, double layers : one is the supporting layer of dense polymer film and the other results revealed that the prepared membranes were efficient to monitor radioactive contamination with reliable counting ability. For enhancement of pick-up and measurement efficiency, the membrane was prepared with the condition of different membrane solidification. The scintillation produced by interaction with radiation and CAYS was measured with photomultiplier tube. The test results showed that the prepared

  17. Diamond blade grinding as a means for removing surface contamination from concrete

    International Nuclear Information System (INIS)

    Lynch, T.W.

    1980-01-01

    The use of a highway grinding unit for the decontamination of a 5,000 square foot surface is described. The type of equipment presently in use is described. Performance characteristics, waste collection and water usage are commented on. Variables in blade design are discussed. Feasibility of the grinding technique for water soluble contaminants and vertical surfaces is referred to

  18. Development of inspection techniques for quantitatively measuring surface contamination on SRM hardware

    Science.gov (United States)

    Law, R. D.

    1989-01-01

    A contaminant is any material or substance which is potentially undesirable or which may adversely affect any part, component, or assembly. Contamination control of SRM hardware surfaces is a serious concern, for both Thiokol and NASA, with particular concern for contaminants which may adversely affect bonding surfaces. The purpose of this study is to develop laboratory analytical techniques which will make it possible to certify the cleanliness of any designated surface, with special focus on particulates (dust, dirt, lint, etc.), oils (hydrocarbons, silicones, plasticizers, etc.), and greases (HD-2, fluorocarbon grease, etc.). The hardware surfaces of concern will include D6AC steel, aluminum alloys, anodized aluminum alloys, glass/phenolic, carbon/phenolic, NBR/asbestos-silica, and EPDM rubber.

  19. Fixation of soil surface contamination using natural polysaccharides

    International Nuclear Information System (INIS)

    Sackschewsky, M.R.

    1993-09-01

    Natural polysaccharides were evaluated as alternatives to commercially available dust-control agents for application in buried-waste and contaminated-soil remediation situations. Materials were identified and evaluated with specific criteria in mind: the materials must be environmentally benign and must not introduce any additional hazardous materials; they must be effective for at least 2 or 3 days, but they do not necessarily have to be effective for more than 2 to 3 weeks; they should be relatively resistant to light traffic; they must not interfere with subsequent soil treatment techniques, especially soil washing; and they must be relatively inexpensive. Two products, a pregelled potato starch and a mixture of carbohydrates derived from sugar beets, were selected for evaluation. Testing included small- and large-scale field demonstrations, laboratory physical property analyses, and wind-tunnel evaluations

  20. The Development of a Sub-Surface Monitoring System for Organic Contamination in Soils and Groundwater

    Directory of Open Access Journals (Sweden)

    Sharon L. Huntley

    2002-01-01

    Full Text Available A major problem when dealing with environmental contamination is the early detection and subsequent surveillance of the contamination. This paper describes the potential of sub-surface sensor technology for the early detection of organic contaminants in contaminated soils, sediments, and landfill sites. Rugged, low-power hydrocarbon sensors have been developed, along with a data-logging system, for the early detection of phase hydrocarbons in soil. Through laboratory-based evaluation, the ability of this system to monitor organic contamination in water-based systems is being evaluated. When used in conjunction with specific immunoassays, this can provide a sensitive and low-cost solution for long-term monitoring and analysis, applicable to a wide range of field applications.

  1. Application Of The SPV-based Surface Lifetime Technique To In-Line Monitoring Of Surface Cu Contamination

    Science.gov (United States)

    D'Amico, John; Savtchouk, Alexandre; Wilson, Matthew; Kim, Chul Hong; Yoo, Hyung Won; Lee, Chang Hwan; Kim, Tae Kyoung; Son, Sang Hoon

    2009-09-01

    Implementation of Cu interconnects into Silicon Integrated Circuits (IC's) has been instrumental in the continuing improvement of IC device performance. Copper as a well known Gate Oxide Integrity (GOI) killer [1, 2] requires extensive protocols to minimize the possibility of cross contamination. Despite such protocols the risk for cross contamination exists, and consequently there is the need for in-line Cu cross-contamination detection metrology. Preferably the metrology will be non-destructive, fast, and capable of mapping on product wafers. Up to now the most common approaches for monitoring Cu contamination in IC fabrication lines either measure Cu in the bulk Si, which is not applicable to Cu cross-contamination monitoring because Back-End-of-the-Line thermal budgets restrict the ability to diffuse the surface Cu into the bulk Si; or the techniques are not optimal for in-line monitoring due to their destructive, time-consuming, or costly nature. In this work we demonstrate for the first time the application of the ac-Surface Photo Voltage (ac-SPV) surface lifetime approach [3] to in-line, full wafer coverage mapping of low level (metrology system. Furthermore, because the metrology is non-contact (utilizing edge-grip handling) and non-destructive, it is directly applicable to measurement of production wafers. In-line fab data acquired using this metrology is presented and compared to data from Inductively Coupled Plasma Mass Spectroscopy (ICP-MS).

  2. [Observation of topography and analysis of surface contamination of titanium implant after roughness treatment].

    Science.gov (United States)

    Cao, Hongdan; Yang, Xiaodong; Wu, Dayi; Zhang, Xingdong

    2007-04-01

    The roughness treatment of dental implant surface could improve the bone bonding and increase the success rate of implant, but the difference of diverse treatments is still unknown. In this study using scanning electron microscopy (SEM), energy disperse spectrometer (EDS) and the test of contact angle, we studied the microstructure, surface contamination and surface energy, and hence conducted a comparative analysis of the following surface roughness treatments: Polished Treatment (PT), Sandblasting with Alumina(SA), Sandblasting with Aluminia and Acid-etched (SAA), Sandblasting with Titanium Acid-etched (STA), Electro-erosion Treatment(ET). The result of SEM showed that the surface displayed irregularities after roughness treatments and that the surface properties of different roughness treatments had some distinctions. SAA and SA had some sharp edges and protrutions; the STA showed a regular pattern like honeycomb, but the ET sample treated by electric erosion exhibited the deeper pores of different sizes and the pores with a perforated secondary structure. The EDS indicated that the surface was contaminated after the treatment with foreign materials; the SA surface had some embedded contaminations even after acid etching. The measurement of water contact angle indicated that the morphology correlated with the surface treatments. These findings suggest that the distinction of surface structure and composition caused by different treatments may result in the disparity in biological behavior of dental implant.

  3. Surface sterilization method for reducing microbial contamination of ...

    African Journals Online (AJOL)

    An effective disinfection method for strawberry (Fragaria x ananassa Duch.) cv. Senga Sengana micropropagation using runner tips and nodal segments as explants was developed. The explants were surface sterilized with different sterilants for different durations. The present studies on the effect of different regimes of ...

  4. use of the RESRAD-BUILD code to calculate building surface contamination limits

    International Nuclear Information System (INIS)

    Faillace, E.R.; LePoire, D.; Yu, C.

    1996-01-01

    Surface contamination limits in buildings were calculated for 226 Ra, 230 Th, 232 Th, and natural uranium on the basis of 1 mSv y -1 (100 mrem y -1 ) dose limit. The RESRAD-BUILD computer code was used to calculate these limits for two scenarios: building occupancy and building renovation. RESRAD-BUILD is a pathway analysis model designed to evaluate the potential radiological dose incurred by individuals working or living inside a building contaminated with radioactive material. Six exposure pathways are considered in the RESRAD-BUILD code: (1) external exposure directly from the source; (2) external exposure from materials deposited on the floor; (3) external exposure due to air submersion; (4) inhalation of airborne radioactive particles; (5) inhalation of aerosol indoor radon progeny; and (6) inadvertent ingestion of radioactive material, either directly from the sources or from materials deposited on the surfaces. The code models point, line, area, and volume sources and calculates the effects of radiation shielding, building ventilation, and ingrowth of radioactive decay products. A sensitivity analysis was performed to determine how variations in input parameters would affect the surface contamination limits. In most cases considered, inhalation of airborne radioactive particles was the primary exposure pathway. However, the direct external exposure contribution from surfaces contaminated with 226 Ra was in some cases the dominant pathway for building occupancy depending on the room size, ventilation rates, and surface release fractions. The surface contamination limits are most restrictive for 232 Th, followed by 230 Th, natural uranium, and 226 Ra. The results are compared with the surface contamination limits in the Nuclear Regulatory Commission's Regulatory Guide 1.86, which are most restrictive for 226 Ra and 230 Th, followed by 232 Th, and are least restrictive for natural uranium

  5. Surface contamination of hazardous drug pharmacy storage bins and pharmacy distributor shipping containers.

    Science.gov (United States)

    Redic, Kimberly A; Fang, Kayleen; Christen, Catherine; Chaffee, Bruce W

    2018-03-01

    Purpose This study was conducted to determine whether there is contamination on exterior drug packaging using shipping totes from the distributor and carousel storage bins as surrogate markers of external packaging contamination. Methods A two-part study was conducted to measure the presence of 5-fluorouracil, ifosfamide, cyclophosphamide, docetaxel and paclitaxel using surrogate markers for external drug packaging. In Part I, 10 drug distributor shipping totes designated for transport of hazardous drugs provided a snapshot view of contamination from regular use and transit in and out of the pharmacy. An additional two totes designated for transport of non-hazardous drugs served as controls. In Part II, old carousel storage bins (i.e. those in use pre-study) were wiped for snapshot view of hazardous drug contamination on storage bins. New carousel storage bins were then put into use for storage of the five tested drugs and used for routine storage and inventory maintenance activities. Carousel bins were wiped at time intervals 0, 8, 16 and 52 weeks to measure surface contamination. Results Two of the 10 hazardous shipping totes were contaminated. Three of the five-old carousel bins were contaminated with cyclophosphamide. One of the old carousel bins was also contaminated with ifosfamide. There were no detectable levels of hazardous drugs on any of the new storage bins at time 0, 8 or 16 weeks. However, at the Week 52, there was a detectable level of 5-FU present in the 5-FU carousel bin. Conclusions Contamination of the surrogate markers suggests that external packaging for hazardous drugs is contaminated, either during the manufacturing process or during routine chain of custody activities. These results demonstrate that occupational exposure may occur due to contamination from shipping totes and storage bins, and that handling practices including use of personal protective equipment is warranted.

  6. Deuteriding of thin titanium films: the effect of carbon monoxide surface contamination

    International Nuclear Information System (INIS)

    Malinowski, M.W.

    1976-02-01

    The effect of adsorbed CO on the deuteriding of thin titanium films at room temperature was measured at D 2 pressures between 10 to 25 mtorr on films contaminated with CO exposures ranging between approximately 10 -8 torr-seconds (''clean'') to 10 -4 torr-seconds. In all measurements, for deuterium/titanium atom ratios greater than .2, the deuteriding appeared to be initally limited by the sticking of D 2 on the clean or contaminated titanium deuteride surface; the effective sticking coefficient on a clean titanium deuteride surface was approximately 3 x 10 -3 , while on a surface contaminated with 10 -4 torr-seconds of CO, the coefficient was reduced to approximately, 2 x 10 -4 . The pumping speeds of Ti films were dramatically different when the films were evaporated over TiD 2 . These changes were attributed to the presence of deuterium which diffused from the substrate film into the overlayer film

  7. Development of the automatic measuring system to survey the surface contamination on equipments

    International Nuclear Information System (INIS)

    Ishizuka, Akira; Matsumura, Hidekatsu; Nawa, Takao; Yamaguchi, Seiji; Yamada, Tadashi.

    1980-01-01

    The inspection of surface contamination carried out when things are taken out of the control areas in nuclear power stations requires considerable labor and time because it is carried out manually. In order to make the inspection of surface contamination more efficiently and to standardize it, the development of an automatic inspection apparatus was carried out. This apparatus inspects the surface contamination due to radio isotopes which do not emit α-ray, and the objects to be measured are the large things with definite forms, such as boards and pipes for scaffolding. The method of measuring β-ray with a gas flow counter was adopted for the apparatus in view of the good detection sensitivity, relatively simple shielding against background, and easy conversion to surface contamination density. The measuring system was composed of the gas flow counters and a rate meter. The outline of the apparatus made for trial is explained. As the result of the performance test, the lowest detection sensitivity was 1.29 x 10 -5 μCi/cm 2 at the moving speed of an object of 1 cm/sec. The detection sensitivity is improved by the flattening of the sensitivity distribution. The evaluation of the error, the reduction of measuring time and the prevention of contamination were also made. (Kako, I.)

  8. Surface sediment quality relative to port activities: A contaminant-spectrum assessment.

    Science.gov (United States)

    Yu, Shen; Hong, Bing; Ma, Jun; Chen, Yongshan; Xi, Xiuping; Gao, Jingbo; Hu, Xiuqin; Xu, Xiangrong; Sun, Yuxin

    2017-10-15

    Ports are facing increasing environmental concerns with their importance to the global economy. Numerous studies indicated sediment quality deterioration in ports; however, the deterioration is not discriminated for each port activity. This study investigated a spectrum of contaminants (metals and organic pollutants) in surface sediments at 20 sampling points in Port Ningbo, China, one of the top five world ports by volume. The spectrum of contaminants (metals and organic pollutants) was quantified following marine sediment quality guidelines of China and USA and surface sediment quality was assessed according to thresholds of the two guidelines. Coupling a categorical matrix of port activities with the matrix of sedimentary contaminants revealed that contaminants were highly associated with the port operations. Ship repair posed a severe chemical risk to sediment. Operations of crude oil and coal loadings were two top activities related to organic pollutants in sediments while port operations of ore and container loadings discharged metals. Among the 20 sampling points, Cu, Zn, Pb, and DDT and its metabolites were the priority contaminants influencing sediment quality. Overall, surface sediments in Port Ningbo had relatively low environmental risks but ship repair is an environmental concern that must be addressed. This study provides a practical approach for port activity-related quality assessment of surface sediments in ports that could be applicable in many world sites. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Second IRMF comparison of surface contamination monitor calibrations 2001-2002

    CERN Document Server

    Scott, C J

    2002-01-01

    The Ionising Radiations Metrology Forum (IRMF) organised a second comparison of surface contamination monitor calibrations in which twenty establishments in the UK participated. The exercise involved the circulation of three surface contamination monitors for calibration using large area reference sources available in the participants' laboratories. The instruments used were a Mini Instruments EP15, a Berthold LB122 and an Electra ratemeter with DP6AD probe. The instrument responses were calculated by the individual participants and submitted to the for analysis along with details of the reference sources used. Details of the estimated uncertainties were also reported. The results are compared and demonstrate generally satisfactory agreement between the participating establishments.

  10. Effect of surface contaminants on the light emission spectrum of LiF TLDs

    International Nuclear Information System (INIS)

    Abhold, M.E.

    1987-01-01

    Recent results show the differences between the light emissions spectra from LiF Thermoluminescent Dosimeters (TLDs) for gamma vs. alpha irradiations to be due to contaminants on the surface of the TLD. The light emission spectrum for thermal neutron irradiations was observed to be identical to that for a Cs-137 gamma irradiation in Harshaw TLD-100. Further experiments with surface treatments on TLD-100 indicate trace contaminants introduced by the standard methanol cleansing rinse in reagent grade methanol to have a substantial effect on the light emission spectrum for Am-241 alpha irradiations

  11. Surface contamination effects on leaf chemical composition in the Atlantic Forest

    International Nuclear Information System (INIS)

    Ferrari, A.A.; Franca, E.J.; Fernandes, E.A.N.; Bacchi, M.A.

    2006-01-01

    The exogenous material that adheres to the leaf surface affects the elemental composition of the plant itself, thereby constituting one of the major error sources in plant analysis. The present work investigated the surface contamination of leaves from the Atlantic Forest. Instrumental neutron activation analysis (INAA) was applied to assess the efficiency of leaf EDTA-washing. Chemical element concentrations were corrected using Sc (soil tracer) since resuspended soil is the main source of contamination in leaves. As a result, EDTA-washing should be used mainly for the evaluation of terrigenous elements, while the Sc-corrected concentrations are considered satisfactory for the other elements. (author)

  12. Chemometric Analysis of Selected Organic Contaminants in Surface Water of Langat River Basin

    International Nuclear Information System (INIS)

    Mohamad Rafaie Mohamed Zubir; Rozita Osman; Norashikin Saim

    2016-01-01

    Chemometric techniques namely hierarchical agglomerative cluster analysis (HACA), discriminant analysis (DA), principal component analysis (PCA) and factor analysis (FA) were applied to the distribution of selected organic contaminants (polycyclic aromatic hydrocarbons (PAHs), sterols, pesticides (chloropyrifos), and phenol) to assess the potential of using these organic contaminants as chemical markers in Langat River Basin. Water samples were collected from February 2012 to January 2013 on a monthly basis for nine monitoring sites along Langat River Basin. HACA was able to classify the sampling sites into three clusters which can be correlated to the level of contamination (low, moderate and high contamination sites). DA was used to discriminate the sources of contamination using the selected organic contaminants and relate to the existing DOE local activities groupings. Forward and backward stepwise DA was able to discriminate two and five organic contaminants variables, respectively, from the original 13 selected variables. The five significant variables identified using backward stepwise DA were fluorene, pyrene, stigmastanol, stigmasterol and phenol. PCA and FA (varimax functionality) were used to identify the possible sources of each organic contaminant based on the inventory of local activities. Five principal components were obtained with 66.5 % of the total variation. Result from FA indicated that PAHs (pyrene, fluorene, acenaphthene, benzo[a]anthracene) originated from industrial activity and socio-economic activities; while sterols (coprostanol, stigmastanol and stigmasterol) were associated to domestic sewage and local socio-economic activities. The occurrence of chloropyrifos was correlated to agricultural activities, urban and domestic discharges. This study showed that the application of chemometrics on the distribution of selected organic contaminants was able to trace the sources of contamination in surface water. (author)

  13. Atmospheric-Pressure Plasma Cleaning of Contaminated Surfaces

    International Nuclear Information System (INIS)

    Hicks, Robert F.; Selwyn, Gary S.

    2001-01-01

    Project was to develop a low-cost, environmentally benign technology for the decontamination and decommissioning of transuranic waste. With the invention of the atmospheric-pressure plasma jet the goal was achieved. This device selectively etches heavy metals from surfaces, rendering objects radiation free and suitable for decommissioning. The volatile reaction products are captured on filters, which yields a tremendous reduction in the volume of the waste. Studies on tantalum, a surrogate material for plutonium, have shown that etch rate of 6.0 microns per minute can be achieved under mild conditions. Over the past three years, we have made numerous improvements in the design of the plasma jet. It may now be operated for hundreds of hours and not undergo any degradation in performance. Furthermore, small compact units have been developed, which are easily deployed in the field

  14. Force control of a robot for surface contamination detection

    International Nuclear Information System (INIS)

    Petterson, B.J.; Jones, J.F.

    1987-01-01

    A system is under development at Sandia National Laboratories for use in understanding the issues relating to automated robotic handling of spent nuclear fuel shipping casks. The goal of robotic handling is reduction of personnel radiation exposure at the proposed geologic repositories. One of the major technology development areas has been the integration of sensors into the control of the robot system to allow operation in semi-structured environments. In particular, a multiaxis force sensor is used to make robot trajectory corrections based on the contact force between the robot and workpiece. This force feedback system allows contact swipes (smears) to be made on the cask surface in a repeatable manner. 8 refs., 3 figs

  15. Atmospheric-Pressure Plasma Cleaning of Contaminated Surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Robert F. Hicks; Gary S. Selwyn

    2001-01-09

    Project was to develop a low-cost, environmentally benign technology for the decontamination and decommissioning of transuranic waste. With the invention of the atmospheric-pressure plasma jet the goal was achieved. This device selectively etches heavy metals from surfaces, rendering objects radiation free and suitable for decommissioning. The volatile reaction products are captured on filters, which yields a tremendous reduction in the volume of the waste. Studies on tantalum, a surrogate material for plutonium, have shown that etch rate of 6.0 microns per minute can be achieved under mild conditions. Over the past three years, we have made numerous improvements in the design of the plasma jet. It may now be operated for hundreds of hours and not undergo any degradation in performance. Furthermore, small compact units have been developed, which are easily deployed in the field.

  16. Synthesis of surface molecular imprinted polymers based on carboxyl-modified silica nanoparticles with the selective detection of dibutyl phthalate from tap water samples

    Science.gov (United States)

    Xu, Wanzhen; Zhang, Xiaoming; Huang, Weihong; Luan, Yu; Yang, Yanfei; Zhu, Maiyong; Yang, Wenming

    2017-12-01

    In this work, the molecular imprinted polymers were synthesized with the low monomer concentrations for dibutyl phthalate (DBP). The polymers were prepared over carboxyl-modified silica nanoparticle, which used methacrylic acid as the functional monomer, ethylene glycol dimethacrylate as the cross-linker agent and azoisobutyronitrile as the initiator in the process of preparation. Various measures were used to characterize the structure and morphology in order to get the optimal polymer. The characterization results show that the optimal polymer has suitable features for further adsorption process. And adsorption capacity experiments were evaluated to analyze its adsorption performance, through adsorption isotherms/kinetics, selectivity adsorption and desorption and regeneration experiments. These results showed that the molecular imprinted polymers had a short equilibrium time about 60 min and high stability with 88% after six cycles. Furthermore, the molecular imprinted polymers were successfully applied to remove dibutyl phthalate. The concentration range was 5.0-30.0 μmol L-1, and the limit of detection was 0.06 μmol L-1 in tap water samples.

  17. Derived surface contamination limits for the uranium mining and milling industry

    International Nuclear Information System (INIS)

    Ching, S.H.

    1984-10-01

    Derived Surface Contamination Limits (DSCL) are proposed for the control of surface contamination at the work place for the uranium mining and milling industry. They have been derived by a method incorporating recent ICRP recommendations and consideration of the radiation exposure pathways of ingestion, inhalation and external irradiation of the basal layer of skin. A generalized DSCL of 10 5 Bq/m 2 of beta activity is recommended for all contaminants likely to be found in uranium mine and mill workplaces except for fresh uranium concentrates. In the latter case, the DSCL is expressed in terms of alpha activity because the ratio of beta to alpha activities for fresh uranium concentrates is variable; the beta activity increases with the ingrowth of U-238 daughter products (Th-234 and Pa-234m) until secular equilibrium is re-established in about six months. A surface contamination limit of 10 4 Bq/m 2 of beta activity is proposed for the release of non-porous materials and equipment with no detectable loose contamination to the public domain

  18. Concentration and toxicity of sea-surface contaminants in Puget Sound

    Energy Technology Data Exchange (ETDEWEB)

    Hardy, J.T.; Crecelius, E.A.; Kocan, R.

    1986-04-01

    The Marine Research Laboratory conducted studies during CY 1985 to evaluate the effects of sea-surface contamination on the reproductive success of a valued marine species. Microlayer and bulk water samples were collected from a rural bay, central Puget Sound, and three urban bays and analyzed for a number of metal and organic contaminants as well as for densities of neuston and plankton organisms. Fertilized neustonic eggs of sand sole (Psettichthys melanostictus) were exposed to the same microlayer samples during their first week of embryonic and larval development. Also, we evaluated the effects of microlayer extracts on the growth of trout cell cultures. Compared to rural sites, urban bays generally contained lower densities of neustonic flatfish eggs during the spawning season. Also, in contrast to the rural sites or the one central Puget Sound site, approximately half of the urban bay microlayer samples resulted in significant increases in embryo mortality (up to 100%), kyphosis (bent spine abnormalities) in hatched larvae, increased anaphase aberrations in developing embryos, and decreased trout cell growth. The toxic samples generally contained high concentrations of polycyclic aromatic and/or chlorinated hydrocarbons and/or potentially toxic metals. In some cases, concentrations of contaminants on the sea surface exceeded water-quality criteria by several orders of magnitude. Several samples of subsurface bulk water collected below highly contaminated surfaces showed no detectable contamination or toxicity.

  19. Experimental analysis on removal factor of smear method in measurement of surface contamination

    International Nuclear Information System (INIS)

    Sugiura, Nobuyuki; Taira, Junichi; Takenaka, Keisuke; Yamanaka, Kazuo; Sugai, Kenji; Kosako, Toshiso

    2007-01-01

    The smear test is one of the important ways to measure surface contamination. The loose contamination under the high background radiation, which is more significant in handling non-sealed radioisotopes, can be evaluated by this method. The removal factor is defined as the ratio of the activity removed from the surface by one smear to the whole activity of the removable surface contamination. The removal factor is greatly changed by the quality and condition of surface materials. In this study, the values of removal factor at several typical surface conditions were evaluated experimentally and the practical application of those values was considered. It is required the smear should be pressed by moderate pressure when wiping the surface. The pressure from 1.0 kg to 1.5 kg per filter paper was recommended. The removal factor showed lower value in wiping by the pressure below 1.0 kg. The value of 0.5 for the removal factor could be applied to the smooth surface of linoleum, concrete coated with paint or epoxy resin, stainless steel and glass with the statistical allowance. (author)

  20. Dosimetry of skin-contact exposure to tritium gas contaminated surfaces

    International Nuclear Information System (INIS)

    Legare, M.

    1990-12-01

    The radiological hazards from tritium are usually associated with exposure to tritium oxide either by inhalation, ingestion or permeation through skin. However, exposure from skin contact with tritium gas contaminated surfaces represents a different radiological hazard in tritium removal facilities and future fusion power plants. Previous experiments on humans and more recent experiments on hairless rats at Chalk River Laboratories have shown that when a tritium gas-contaminated surface is brought into contact with intact skin, high concentrations of organically-bound tritium in urine and skin are observed which were not seen from single tritiated water (liquid or vapour form) contamination. The results of the rat experiments, which involved measurements of tritium activity in urine and skin, after contact with contaminated stainless steel, are described. These results are also compared to previous data from human experiments. The effect of various exposure conditions and different contaminated surfaces such as brass, aluminum and glass are analysed and related to the results from contaminated stainless steel exposure. Dosimetric models are being developed in order to improve the basis for dose assessment for this mode of tritium uptake. The presently studied model is explained along with the assumptions and methods involved in its derivation. The features of 'STELLA', the software program used to implement the model, are discussed. The methods used to estimate skin and whole body dose from a model are demonstrated. Finally, some experiments for improving the accuracy of the model are proposed. Briefly, this study compares the results from animal and human experiments as well as different exposure conditions, and determines the range of whole body and skin dose that may be involved from skin-contact intake. This information is essential for regulatory purposes particularly in the derivation of doses for skin-contact contamination. (15 figs., 7 tabs., 29 refs.)

  1. The influence of Triga 2000 reactor operation on the surface contamination at reactor room using smear test method

    International Nuclear Information System (INIS)

    Bintu Khoiriyyah; Budi Purnama; Tri Cahyo Laksono

    2016-01-01

    The monitoring of surface contamination should be conducted to determine the safety of work areas. Surface contamination at the TRIGA 2000 reactor room which is on PSTNT-BATAN Bandung remain to be implemented although reactor not operating. In this research monitoring of surface contamination when TRIGA 2000 in operation of the first time after several years not operating aims to determine the influence on the results of monitoring. The monitoring of surface contamination has been done using smear test method at some predetermined in TRIGA 2000 reactor room. The highest surface contamination activities is obtained 0.32 Bq/cm 2 and there are some points that are not detected. Based on keputusan kepala BAPETEN No.1/Ka BAPETEN/ V/99 the work showed that the TRIGA 2000 reactor in the category of low area contamination, that is <3.7 Bq/cm 2 to gross beta. (author)

  2. Effectiveness of disinfectant wipes for decontamination of bacteria on patients' environmental and medical equipment surfaces at Siriraj Hospital.

    Science.gov (United States)

    Seenama, Chakkraphong; Tachasirinugune, Peenithi; Jintanothaitavorn, Duangporn; Kachintorn, Kanchana; Thamlikitkul, Visanu

    2013-02-01

    To determine the effectiveness of Virusolve+ disinfectant wipes and PAL disinfectant wipes for decontamination of inoculated bacteria on patients' environmental and medical equipment surfaces at Siriraj Hospital. Tryptic soy broths containing MRSA and XDR A. baumannii were painted onto the surfaces of patient's stainless steel bed rail, patient's fiber footboard, control panel of infusion pump machine and control panel of respirator. The contaminated surfaces were cleaned by either tap water, tap water containing detergent, Virusolve+ disinfectant wipes or PAL disinfectant wipes. The surfaces without any cleaning procedures served as the control surface. The contaminated surfaces cleaned with the aforementioned procedures and control surfaces were swabbed with cotton swabs. The swabs were streaked on agar plates to determine the presence of MRSA and XDR A. baumannii. MRSA and XDR A. baumannii were recovered from all control surfaces. All surfaces cleaned with tap water or tap water containing detergent revealed presence of both MRSA and XDR A. baumannii. However the amounts of bacteria on the surfaces cleaned with tap water containing detergent were less than those cleaned with tap water alone. All surfaces cleaned with PAL disinfectant wipes also revealed presence of both MRSA and XDR A. baumannii. However the amounts of bacteria on the surfaces cleaned with PAL disinfectant wipes were less than those cleaned with tap water containing detergent. No bacteria were recovered from all surfaces cleaned with Virusolve+ disinfectant wipes. Virusolve+ disinfectant wipes were more effective than tap water; tap water containing detergent and PAL disinfectant wipes for decontamination of bacteria inoculated on patients environmental and medical equipment surfaces at Siriraj Hospital.

  3. Resistance of Pseudomonas aeruginosa to liquid disinfectants on contaminated surfaces before formation of biofilms.

    Science.gov (United States)

    Sagripanti, J L; Bonifacino, A

    2000-01-01

    A comparison was made of the effectiveness of popular disinfectants (Cavicide, Cidexplus, Clorox, Exspor, Lysol, Renalin, and Wavicide) under conditions prescribed for disinfection in the respective product labels on Pseudomonas aeruginosa either in suspension or deposited onto surfaces of metallic or polymeric plastic devices. The testing also included 7 nonformulated germicidal agents (glutaraldehyde, formaldehyde, peracetic acid, hydrogen peroxide, sodium hypochlorite, phenol, and cupric ascorbate) commonly used in disinfection and decontamination. Results showed that P. aeruginosa is on average 300-fold more resistant when present on contaminated surfaces than in suspension. This increase in resistance agrees with results reported in studies of biofilms, but unexpectedly, it precedes biofilm formation. The surface to which bacteria are attached can influence the effectiveness of disinfectants. Viable bacteria attached to devices may require dislodging through more than a one-step method for detection. The data, obtained with a sensitive and quantitative test, suggest that disinfectants are less effective on contaminated surfaces than generally acknowledged.

  4. Aluminum-contaminant transport by surface runoff and bypass flow from an acid sulphate soil

    NARCIS (Netherlands)

    Minh, L.Q.; Tuong, T.P.; Mensvoort, van M.E.F.; Bouma, J.

    2002-01-01

    Quantifying the process and the amount of acid-contaminant released to the surroundings is important in assessing the environmental hazards associated with reclaiming acid sulphate soils (ASS). The roles of surface runoff and bypass flow (i.e. the rapid downward flow of free water along macropores

  5. Bond strength of resin-resin interfaces contaminated with saliva and submitted to different surface treatments

    DEFF Research Database (Denmark)

    Furuse, Adilson Yoshio; da Cunha, Leonardo Fernandes; Benetti, Ana Raquel

    2007-01-01

    of silane and adhesive system. Resin cylinders were placed over the treated surfaces. The specimens were stored in water or ethanol. Shear bond strength tests were performed and the mode of failure was evaluated. Data were submitted to two-way ANOVA and Dunnett T3 test. Contamination of resin...

  6. A new technique for the identification of surface contamination in low temperature bolometric experiments

    International Nuclear Information System (INIS)

    Sangiorgio, S.; Arnaboldi, C.; Brofferio, C.; Bucci, C.; Capelli, S.; Carbone, L.; Clemenza, M.; Cremonesi, O.; Fiorini, E.; Foggetta, L.; Giuliani, A.; Gorla, P.; Nones, C.; Nucciotti, A.; Pavan, M.; Pedretti, M.; Pessina, G.; Pirro, S.; Previtali, E.; Salvioni, C.

    2011-01-01

    In the framework of the bolometric experiment CUORE, a new and promising technique has been developed in order to control the dangerous contamination coming from the surfaces close to the detector. In fact, by means of a composite bolometer, it is possible to partially overcome the loss of spatial resolution of the bolometer itself and to clearly identify events coming from outside.

  7. TECHNICAL BASIS FOR EVALUATING SURFACE BARRIERS TO PROTECT GROUNDWATER FROM DEEP VADOSE ZONE CONTAMINATION

    International Nuclear Information System (INIS)

    Fayer, J.M.; Freedman, V.L.; Ward, A.L.; Chronister, G.B.

    2010-01-01

    The U.S. DOE and its predecessors released nearly 2 trillion liters (450 billion gallons) of contaminated liquid into the vadose zone at the Hanford Site. Some of the contaminants currently reside in the deeper parts of the vadose zone where they are much less accessible to characterization, monitoring, and typical remediation activities. The DOE Richland Operations Office (DOE-RL) prepared a treatability test plan in 2008 to examine remediation options for addressing contaminants in the deep vadose zone; one of the technologies identified was surface barriers (also known as engineered barriers, covers, and caps). In the typical configuration, the contaminants are located relatively close to the surface, generally within 15 m, and thus they are close to the base of the surface barrier. The proximity of the surface barrier under these conditions yielded few concerns about the effectiveness of the barrier at depth, particularly for cases in which the contaminants were in a lined facility. At Hanford, however, some unlined sites have contaminants located well below depths of 15 m. The issue raised about these sites is the degree of effectiveness of a surface barrier in isolating contaminants in the deep vadose zone. Previous studies by Hanford Site and PNNL researchers suggest that surface barriers have the potential to provide a significant degree of isolation of deep vadose zone contaminants. The studies show that the actual degree of isolation is site-specific and depends on many factors, including recharge rates, barrier size, depth of contaminants, geohydrologic properties ofthe sediments, and the geochemical interactions between the contaminants and the sediments. After the DOE-RL treatability test plan was published, Pacific Northwest National Laboratory was contracted to review the information available to support surface barrier evaluation for the deep vadose zone, identify gaps in the information and outcomes necessary to fill the data gaps, and outline

  8. A new cleaning process for the metallic contaminants on a post-CMP wafer's surface

    International Nuclear Information System (INIS)

    Gao Baohong; Liu Yuling; Wang Chenwei; Wang Shengli; Zhou Qiang; Tan Baimei; Zhu Yadong

    2010-01-01

    This paper presents a new cleaning process using boron-doped diamond (BDD) film anode electrochemical oxidation for metallic contaminants on polished silicon wafer surfaces. The BDD film anode electrochemical oxidation can efficiently prepare pyrophosphate peroxide, pyrophosphate peroxide can oxidize organic contaminants, and pyrophosphate peroxide is deoxidized into pyrophosphate. Pyrophosphate, a good complexing agent, can form a metal complex, which is a structure consisting of a copper ion, bonded to a surrounding array of two pyrophosphate anions. Three polished wafers were immersed in the 0.01 mol/L CuSO 4 solution for 2 h in order to make comparative experiments. The first one was cleaned by pyrophosphate peroxide, the second by RCA (Radio Corporation of America) cleaning, and the third by deionized (DI) water. The XPS measurement result shows that the metallic contaminants on wafers cleaned by the RCA method and by pyrophosphate peroxide is less than the XPS detection limits of 1 ppm. And the wafer's surface cleaned by pyrophosphate peroxide is more efficient in removing organic carbon residues than RCA cleaning. Therefore, BDD film anode electrochemical oxidation can be used for microelectronics cleaning, and it can effectively remove organic contaminants and metallic contaminants in one step. It also achieves energy saving and environmental protection. (semiconductor technology)

  9. Surface Contaminant Control Technologies to Improve Laser Damage Resistance of Optics

    Directory of Open Access Journals (Sweden)

    Xiaofeng Cheng

    2014-01-01

    Full Text Available The large high-power solid lasers, such as the National Ignition Facility (NIF of America and the Shenguang-III (SG-III laser facility of China, can output over 2.1 MJ laser pulse for the inertial confinement fusion (ICF experiments. Because of the enhancement of operating flux and the expansion of laser driver scale, the problem of contamination seriously influences their construction period and operation life. During irradiation by intense laser beams, the contaminants on the metallic surface of beam tubes can be transmitted to the optical surfaces and lead to damage of optical components. For the high-power solid-state laser facilities, contamination control focuses on the slab amplifiers, spatial filters, and final-optical assemblies. In this paper, an effective solution to control contaminations including the whole process of the laser driver is put forward to provide the safe operation of laser facilities, and the detailed technical methods of contamination control such as washing, cleanliness metrology, and cleanliness protecting are also introduced to reduce the probability of laser-induced damage of optics. The experimental results show that the cleanliness level of SG-III laser facility is much better to ensure that the laser facility can safely operate at high energy flux.

  10. Residual viral and bacterial contamination of surfaces after cleaning and disinfection.

    Science.gov (United States)

    Tuladhar, Era; Hazeleger, Wilma C; Koopmans, Marion; Zwietering, Marcel H; Beumer, Rijkelt R; Duizer, Erwin

    2012-11-01

    Environmental surfaces contaminated with pathogens can be sources of indirect transmission, and cleaning and disinfection are common interventions focused on reducing contamination levels. We determined the efficacy of cleaning and disinfection procedures for reducing contamination by noroviruses, rotavirus, poliovirus, parechovirus, adenovirus, influenza virus, Staphylococcus aureus, and Salmonella enterica from artificially contaminated stainless steel surfaces. After a single wipe with water, liquid soap, or 250-ppm free chlorine solution, the numbers of infective viruses and bacteria were reduced by 1 log(10) for poliovirus and close to 4 log(10) for influenza virus. There was no significant difference in residual contamination levels after wiping with water, liquid soap, or 250-ppm chlorine solution. When a single wipe with liquid soap was followed by a second wipe using 250- or 1,000-ppm chlorine, an extra 1- to 3-log(10) reduction was achieved, and except for rotavirus and norovirus genogroup I, no significant additional effect of 1,000 ppm compared to 250 ppm was found. A reduced correlation between reduction in PCR units (PCRU) and reduction in infectious particles suggests that at least part of the reduction achieved in the second step is due to inactivation instead of removal alone. We used data on infectious doses and transfer efficiencies to estimate a target level to which the residual contamination should be reduced and found that a single wipe with liquid soap followed by a wipe with 250-ppm free chlorine solution was sufficient to reduce the residual contamination to below the target level for most of the pathogens tested.

  11. Contaminants of emerging concern in surface waters in Barbados, West Indies.

    Science.gov (United States)

    Edwards, Quincy A; Kulikov, Sergei M; Garner-O'Neale, Leah D; Metcalfe, Chris D; Sultana, Tamanna

    2017-11-14

    Contaminants of emerging concern (CECs), including pharmaceuticals, artificial sweeteners, steroid hormones, and current-use pesticides have been detected in surface waters around the world, but to date, there have been no reports in the peer-reviewed literature on the levels of these classes of contaminants in freshwater resources in the Caribbean region. In the present study, multi-residue solid phase extraction (SPE) and liquid chromatography with tandem mass spectroscopy (LC-MS/MS) were used to analyze grab samples of surface waters collected from five different watersheds in Barbados, West Indies. The artificial sweeteners (AS), acesulfame, cyclamate, saccharin, and sucralose were widely detected in the watersheds, indicating contamination from domestic wastewater, and the concentrations of these chemical tracers in water were correlated with the concentrations of the non-prescription pharmaceutical, ibuprofen (R 2 values of 0.4-0.6). Surprisingly, the concentrations of another chemical tracer of domestic wastewater, caffeine were not correlated with ibuprofen or AS concentrations. Several other prescription pharmaceuticals and the steroid hormones, estrone and androstenedione, were detected in selected watersheds at low ng/L concentrations. The fungicide, chlorothalonil was widely detected in surface waters at low (contamination of water resources by pharmaceuticals.

  12. A decision-making process on cleanup of contaminated surface soil

    International Nuclear Information System (INIS)

    Yasuda, Hiroshi

    1996-01-01

    This study presents principles for determining derived intervention levels (DILs) for surface soil cleanup. The people concerned were divided into major three groups: residents, responsible parties, and cleanup workers; it was considered that each group has different interests. The DILs for soil cleanup were determined from the viewpoints of these three groups: safety of residence, advantages of the countermeasures, and safety of cleanup activities, respectively. An example process for determination of the DILs in accordance with the principles was also presented for a site contaminated by 137 Cs. This decision-making frame is expected to be applicable to other contaminants. (author)

  13. Use of a surface contamination survey simulation program and its effects

    International Nuclear Information System (INIS)

    Onuma, Isamu; Kobayashi, Makoto; Umehara, Takashi; Shimizu, Isamu

    2012-01-01

    A computer simulation program has been developed to train the practitioners examining the surface contamination of objects to be carried out from the controlled area. The efficiency of the examination depends significantly on the proficiency in radiation measurement and proper perception of contamination. It has been demonstrated through the usage of the program that it helps practitioners very much suggest their weakness and promote their skill in examination. The program runs on the commonly used personal computers and users can easily experience the virtual examination by sweeping and cricking the mouse. The program is useful to radiation protection practitioners not only beginners but also experts. (author)

  14. Heavy metal contamination in surface runoff sediments of the urban area of Vilnius, Lithuania

    Directory of Open Access Journals (Sweden)

    Gytautas Ignatavičius

    2017-02-01

    Full Text Available Surface runoff from urbanized territories carries a wide range of pollutants. Sediments in untreated runoff from direct discharge stormwater systems significantly contribute to urban waterway pollution. In this study, heavy metal (Pb, Zn, Cu, Cr, Ba, As and Fe contamination in surface runoff sediments of the urban area of the city of Vilnius was investigated. The surface runoff sediment samples were collected from seven dischargers with the highest volume rate of water flow and concentrations of suspended solids. The geospatial analysis of the distribution of heavy metals shows that there are several active pollution sources supplying the dischargers with contaminated sediments. Most of these areas are located in the central part of the city and in old town with intense traffic. Principal components analysis and t-test results clearly depicted the significantly different chemical compositions of winter and autumn surface sediment samples. The sampling approach and assessment of results provide a useful tool to examine the contamination that is generated in urban areas, distinguish pollution sources and give a better understanding of the importance of permeable surfaces and green areas.

  15. Indoor and Outdoor Surface-Growing Fungi Contamination at Higher Institutional Buildings in a Malaysian University

    Science.gov (United States)

    Er, C. M.; Sunar, N. M.; Leman, A. M.; Khalid, A.; Ali, R.; Zaidi, E.; Azhar, A. T. S.

    2018-04-01

    Surface-growing indoor and outdoor fungi were assessed using swabbing method to investigate the indoor contamination. The painted wall surface samples were collected from two institutional buildings (B1 and B2) of a university in southern Peninsular Malaysia; indoors and outdoors. The mould concentrations varied widely between indoor and outdoor surface samples of both buildings. The total indoor surface-growing mould concentration (8776.49 CFU/cm2) is significantly higher (pair quality parameters (relative humidity, temperature and air velocity) were also measured indoors and outdoors during the study and violation of the guideline provided by ICOP-IAQ 2010 were proven in indoor environment in both buildings. The results of this assessment showed that the indoor environments of both institutional buildings were contaminated by the surface-growing mould. It also suggested the faulty designs and/or usages of building material in these institutional buildings contributed toward the contamination. An innovative solution is needed to correct the problems.

  16. Removal of copper and nickel contaminants from Si surface by use of cyanide solutions

    International Nuclear Information System (INIS)

    Fujiwara, N.; Liu, Y.-L.; Nakamura, T.; Maida, O.; Takahashi, M.; Kobayashi, H.

    2004-01-01

    The cleaning method using cyanide solutions has been developed to remove heavy metals such as copper (Cu) and nickel (Ni) from Si surfaces. Immersion of Si wafers with both Cu and Ni contaminants in potassium cyanide (KCN) solutions of methanol at room temperature decreases these surface concentrations below the detection limit of total reflection X-ray fluorescence spectroscopy of ∼3x10 9 atoms/cm 2 . UV spectra of the KCN solutions after cleaning of the Cu-contaminated Si surface show that stable copper-cyanide complexes are formed in the solution, leading to the prevention of the re-adsorption of copper in the solutions. From the complex stability constants, it is concluded that the Cu(CN) 4 3- is the most dominant species in the KCN solutions

  17. Contribution to Surface Water Contamination Understanding by Pesticides and Pharmaceuticals, at a Watershed Scale

    Directory of Open Access Journals (Sweden)

    Stéphanie Piel

    2012-12-01

    Full Text Available This study aims at understanding the presence of regulated and emerging micropollutants, particularly pesticides and pharmaceuticals, in surface water, regarding spatial and temporal influences at a watershed scale. The study of relations between micropollutants and other water quality and hydroclimatic parameters was carried out from a statistical analysis on historical and experimental data of different sampling sites from the main watershed of Brittany, western France. The outcomes point out the influence of urban and rural areas of the watershed as well as the impact of seasons on contamination variations. This work contributes to health risk assessment related to surface water contamination by micropollutants. This approach is particularly interesting in the case of agricultural watersheds such as the one studied, where more than 80% of surface water is used to produce drinking water.

  18. Laser cleaning of the contaminations on the surface of tire mould

    Science.gov (United States)

    Ye, Yayun; Jia, Baoshen; Chen, Jing; Jiang, Yilan; Tang, Hongping; Wang, Haijun; Luan, Xiaoyu; Liao, Wei; Zhang, Chuanchao; Yao, Caizhen

    2017-07-01

    During the manufacturing of tires, surface pollutants on tire mould will lead to the production of unqualified tires. Tire moulds need to be regularly cleaned. Laser cleaning is recognized as a non-destructive, effective, precise and environmental friendly method. In this paper, laser cleaning was used to remove contaminants on tire mould surface. First, laser induced damage experiments were performed. The results showed that the roughness and hardness of the cast steel sample surface seldom changed under the energy range of 140.1-580.2 mJ laser irradiation 1 pulse and the energy range of 44.7-168.9 mJ laser irradiation 100 pulses. In the laser cleaning experiments, the cleaning thresholds and the optimal cleaning parameters were obtained. Results indicated that laser cleaning was safe and effective for tire mould contamination removal.

  19. PROCEEDINGS WITH CONTAMINATED INDUSTRIAL SITES IN TERMS OF NEW LEGISLATION – PART I. HISTORICAL POLLUTION OF THE EARTH'S SURFACE

    OpenAIRE

    Magdalena Paulina Wiśniewska; Agnieszka Pusz

    2017-01-01

    This article shows a way of dealing with the industrial areas, where historical contamination of the earth’s surface occurred, together with an indication of the proper remediation method selection. Public Administration authorities, including the Regional Director of Environmental Protection (RDOŚ) and the governor are responsible, among others, for identifying areas where historical contamination or potential historical contamination of the earth's surface occurred. General Director of Envi...

  20. Physics of Beer Tapping

    Science.gov (United States)

    Rodríguez-Rodríguez, Javier; Casado-Chacón, Almudena; Fuster, Daniel

    2014-11-01

    The popular bar prank known in colloquial English as beer tapping consists in hitting the top of a beer bottle with a solid object, usually another bottle, to trigger the foaming over of the former within a few seconds. Despite the trick being known for a long time, to the best of our knowledge, the phenomenon still lacks scientific explanation. Although it seems natural to think that shock-induced cavitation enhances the diffusion of CO2 from the supersaturated bulk liquid into the bubbles by breaking them up, the subtle mechanism by which this happens remains unknown. Here, we show that the overall foaming-over process can be divided into three stages where different physical phenomena take place in different time scales: namely, the bubble-collapse (or cavitation) stage, the diffusion-driven stage, and the buoyancy-driven stage. In the bubble-collapse stage, the impact generates a train of expansion-compression waves in the liquid that leads to the fragmentation of preexisting gas cavities. Upon bubble fragmentation, the sudden increase of the interface-area-to-volume ratio enhances mass transfer significantly, which makes the bubble volume grow by a large factor until CO2 is locally depleted. At that point buoyancy takes over, making the bubble clouds rise and eventually form buoyant vortex rings whose volume grows fast due to the feedback between the buoyancy-induced rising speed and the advection-enhanced CO2 transport from the bulk liquid to the bubble. The physics behind this explosive process sheds insight into the dynamics of geological phenomena such as limnic eruptions.

  1. Potential effects of groundwater and surface water contamination in an urban area, Qus City, Upper Egypt

    Science.gov (United States)

    Abdalla, Fathy; Khalil, Ramadan

    2018-05-01

    The potential effects of anthropogenic activities, in particular, unsafe sewage disposal practices, on shallow groundwater in an unconfined aquifer and on surface water were evaluated within an urban area by the use of hydrogeological, hydrochemical, and bacteriological analyses. Physicochemical and bacteriological data was obtained from forty-five sampling points based on33 groundwater samples from variable depths and 12 surface water samples. The pollution sources are related to raw sewage and wastewater discharges, agricultural runoff, and wastewater from the nearby Paper Factory. Out of the 33 groundwater samples studied, 17 had significant concentrations of NO3-, Cl- and SO42-, and high bacteria counts. Most of the water samples from the wells contained high Fe, Mn, Pb, Zn, Cd, and Cr. The majority of surface water samples presented high NO3- concentrations and high bacteria counts. A scatter plot of HCO3- versus Ca indicates that 58% of the surface water samples fall within the extreme contamination zone, while the others are within the mixing zone; whereas 94% of groundwater samples showed evidence of mixing between groundwater and wastewater. The bacteriological assessment showed that all measured surface and groundwater samples contained Escherichia coli and total coliform bacteria. A risk map delineated four classes of contamination, namely, those sampling points with high (39.3%), moderate (36.3%), low (13.3%), and very low (11.1%) levels of contamination. Most of the highest pollution points were in the middle part of the urban area, which suffers from unmanaged sewage and industrial effluents. Overall, the results demonstrate that surface and groundwater in Qus City are at high risk of contamination by wastewater since the water table is shallow and there is a lack of a formal sanitation network infrastructure. The product risk map is a useful tool for prioritizing zones that require immediate mitigation and monitoring.

  2. Radioactive contamination of some rubber or plastic surfaces by fission products. Decontamination tests; Contamination radioactive de quelques surfaces en caoutchouc ou en matiere plastique par des produits de fission. Essais de decontamination

    Energy Technology Data Exchange (ETDEWEB)

    Mestre, E.; Sautiez, N.

    1957-10-15

    With the objective of notably addressing the contamination and decontamination of gloves and floor covering, this report first presents some characteristics of contaminating radioactive materials (nature, physical and chemical condition), of contaminated surfaces (surface condition, surface nature), and of decontamination processes (physical, chemical or mechanical action). It describes the operational modality implemented to test decontamination processes on various glove or flooring materials: sample preparation, counting, decontamination, reproducibility of decontamination tests, results in terms of activity reduction. It more precisely describes the tested samples: short gloves, gloves from glove boxes, floor and wall coverings. Results are presented and discussed in terms of sample susceptibility to contamination, and of decontamination, but also for re-contamination tests after a Nab-based decontamination (susceptibility to contamination, decontamination gain)

  3. Tapping mode microwave impedance microscopy

    KAUST Repository

    Lai, K.; Kundhikanjana, W.; Peng, H.; Cui, Y.; Kelly, M. A.; Shen, Z. X.

    2009-01-01

    We report tapping mode microwave impedance imaging based on atomic force microscope platforms. The shielded cantilever probe is critical to localize the tip-sample interaction near the tip apex. The modulated tip-sample impedance can be accurately

  4. Assessment of Microbial Contamination of Surfaces and Medical Equipment in Wards of the Panjom Azar Hospital of Gorgan in 2014

    Directory of Open Access Journals (Sweden)

    Roghaye Noroozi

    2014-06-01

    Full Text Available Methods: In this cross-sectional study, different wards of panjom Azar educational hospital including ICU, dialysis and surgery room were investigated. Samples were collected randomly, for three months from July to September 2014, from beds, oxygen masks, oxygen manometer, patient table, covers of the patient's medical records, nurse's desk, border walls and water tap.  Samples were then cultured on blood agar and EMB agar. In order to determine the bacteria type, specific culture media with specific biochemical tests and diagnostic disks were used. Results: Results showed that from 216 samples collected from the levels, the 190 cases (88% had microbial contamination. Most of the recognized bacteria were Staphylococcus saprophyticus, Staphylococcus epidermidis, Staphylococcus aureus, Bacillus subtilis, Pseudomonas aeruginosa, Escherichia coli, Enterobacter and klebsiela. Results of microbial culture of equipments and levels were positive in case of bacterial contamination and maximum contamination was observed in the dialysis ward of the hospital. Conclusion: Due to the relatively high detected contamination, contamination control of levels and patient care equipments could considered as an effective action in reducing nosocomial infections. Thus, using appropriate disinfectant equipment, monitoring the disinfectants preparation, continuous monitoring and detection of common microorganisms are the most important ways for infection control in hospitals.

  5. Decontamination of plutonium-contaminated surfaces; Essais de decontamination des surfaces contaminees par du plutonium

    Energy Technology Data Exchange (ETDEWEB)

    Bertrand, J; Clouet d' Orval, Ch; Tachon, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The measure of the neutron distribution in the core of 'Proserpine', by means of activation detectors, requires no contact between the plutonium sulfate solution and the detectors. These detectors are put into PVC or polyethylene bags. This report describes the process used to decontaminate these bags. A washing by nitric acid followed by coating with plexiglass is kept, with this process we have no contamination on the detectors. (author) [French] La mesure de la distribution de neutrons par detecteurs a activation dans le coeur de Proserpine exige de proteger ces detecteurs contre tout contact avec la solution de plutonium. Les detecteurs sont places dans des gaines en polyvinyle ou en polyethylene. Ce rapport decrit le procede utilise pour decontaminer ces gaines. On a retenu un lavage a l'acide nitrique suivi du revetement d'une meme couche de plexiglass, ce qui permet d'eviter la contamination des detecteurs. (auteur)

  6. Skin and surface lead contamination, hygiene programs, and work practices of bridge surface preparation and painting contractors.

    Science.gov (United States)

    Virji, M Abbas; Woskie, Susan R; Pepper, Lewis D

    2009-02-01

    A 2005 regulatory review of the lead in construction standard by the Occupational Safety and Health Administration (OSHA) noted that alternative pathways of exposure can be as significant as inhalation exposure and that noncompliance with the standard pertaining to hygiene facilities and practices was the second most commonly violated section of the standard. Noncompliance with provisions of the standard and unhealthy work and hygiene practices likely increase the likelihood of take-home lead via contaminated clothing, automobiles, and skin, thus contributing to elevated blood lead levels (BLL) among construction workers and their family members. We performed a cross-sectional study of bridge painters working for small contractors in Massachusetts to investigate causes of persistent elevated BLLs and to assess lead exposures. Thirteen work sites were evaluated for a 2-week period during which surface and skin wipe samples were collected and qualitative information was obtained on personal hygiene practices, decontamination and hand wash facilities, and respiratory protection programs. Results showed lead contamination on workers' skin, respirators, personal automobiles, and the decontamination unit, indicating a significant potential for take-home lead exposure. Overall, the geometric mean (GM) skin lead levels ranged from 373 microg on workers' faces at end of shift to 814 microg on hands at break time. The overall GM lead level inside respirators was 143 microg before work and 286 microg after work. Lead contamination was also present inside workers' personal vehicles as well as on surfaces inside the clean side of the decontamination unit. Review of the respiratory protection programs, work site decontamination and hand wash facilities, and personal hygiene practices indicated that these factors had significant impact on skin and surface contamination levels and identified significant opportunities for improving work site facilities and personal practices

  7. Contaminants in surface water and sediments near the Tynagh silver mine site, County Galway, Ireland

    Energy Technology Data Exchange (ETDEWEB)

    O' Neill, A. [School of Planning, Architecture and Civil Engineering, Queen' s University of Belfast, Belfast, Northern Ireland (United Kingdom); Phillips, D.H., E-mail: d.phillips@qub.ac.uk [School of Planning, Architecture and Civil Engineering, Queen' s University of Belfast, Belfast, Northern Ireland (United Kingdom); Bowen, J. [School of Planning, Architecture and Civil Engineering, Queen' s University of Belfast, Belfast, Northern Ireland (United Kingdom); Sen Gupta, B. [School of the Built Environment, Hariot-Watt University, Edinburgh, Scotland (United Kingdom)

    2015-04-15

    A former silver mine in Tynagh, Co. Galway, Ireland is one of the most contaminated mine sites in Europe with maximum concentrations of Zn, As, Pb, Mn, Ni, Cu, and Cd far exceeding guideline values for water and sediment. The aims of this research were to 1) further assess the contamination, particularly metals, in surface water and sediment around the site, and 2) determine if the contamination has increased 10 years after the Environmental Protection Agency Ireland (EPAI) identified off-site contamination. Site pH is alkaline to neutral because CaCO{sub 3}-rich sediment and rock material buffer the exposed acid generating sulphide-rich ore. When this study was compared to the previous EPAI study conducted 10 years earlier, it appeared that further weathering of exposed surface sediment had increased concentrations of As and other potentially toxic elements. Water samples from the tailings ponds and adjacent Barnacullia Stream had concentrations of Al, Cd, Mn, Zn and Pb above guideline values. Lead and Zn concentrations from the tailings pond sediment were 16 and 5 times higher, respectively, than concentrations reported 10 years earlier. Pb and Zn levels in most sediment samples exceeded the Expert Group (EGS) guidelines of 1000 and 5000 mg/kg, respectively. Arsenic concentrations were as high as 6238 mg/kg in the tailings ponds sediment, which is 62 and 862 times greater than the EGS and Canadian Soil Quality Guidelines (CSQG), respectively. Cadmium, Cu, Fe, Mn, Pb and Zn concentrations in water and sediment were above guideline values downstream of the site. Additionally, Fe, Mn and organic matter (OM) were strongly correlated and correlated to Zn, Pb, As, Cd, Cu and Ni in stream sediment. Therefore, the nearby Barnacullia Stream is also a significant pathway for contaminant transport to downstream areas. Further rehabilitation of the site may decrease the contamination around the area. - Highlights: • Tynagh silver mine in Co. Galway, Ireland is a source of

  8. Microbial air quality and bacterial surface contamination in ambulances during patient services.

    Science.gov (United States)

    Luksamijarulkul, Pipat; Pipitsangjan, Sirikun

    2015-03-01

    We sought to assess microbial air quality and bacterial surface contamination on medical instruments and the surrounding areas among 30 ambulance runs during service. We performed a cross-sectional study of 106 air samples collected from 30 ambulances before patient services and 212 air samples collected during patient services to assess the bacterial and fungal counts at the two time points. Additionally, 226 surface swab samples were collected from medical instrument surfaces and the surrounding areas before and after ambulance runs. Groups or genus of isolated bacteria and fungi were preliminarily identified by Gram's stain and lactophenol cotton blue. Data were analyzed using descriptive statistics, t-test, and Pearson's correlation coefficient with a p-value of less than 0.050 considered significant. The mean and standard deviation of bacterial and fungal counts at the start of ambulance runs were 318±485cfu/m(3) and 522±581cfu/m(3), respectively. Bacterial counts during patient services were 468±607cfu/m(3) and fungal counts were 656±612cfu/m(3). Mean bacterial and fungal counts during patient services were significantly higher than those at the start of ambulance runs, p=0.005 and p=0.030, respectively. For surface contamination, the overall bacterial counts before and after patient services were 0.8±0.7cfu/cm(2) and 1.3±1.1cfu/cm(2), respectively (pair samples and bacterial counts on medical instruments and allocated areas. This study revealed high microbial contamination (bacterial and fungal) in ambulance air during services and higher bacterial contamination on medical instrument surfaces and allocated areas after ambulance services compared to the start of ambulance runs. Additionally, bacterial and fungal counts in ambulance air showed a significantly positive correlation with the bacterial surface contamination on medical instruments and allocated areas. Further studies should be conducted to determine the optimal intervention to reduce

  9. Emerging contaminants in surface waters in China—a short review

    International Nuclear Information System (INIS)

    Yang, Guang; Zhang, Guangming; Fan, Maohong

    2014-01-01

    Emerging contaminants (ECs) have drawn attention to many countries due to their persistent input and potential threat to human health and the environment. This article reviews the current contamination sources and their status for surface waters in China. The contamination levels of ECs in surface waters are in the range ng L −1 to μg L −1 in China, apparently about the same as the situation in other countries. ECs enter surface water via runoff, drainage, rainfall, and wastewater treatment effluent. The frequency of occurrence of ECs increased rapidly from 2006 to 2011; a significant reason is the production and consumption of pharmaceuticals and personal care products. As for the distribution of EC pollution in China, the frequency of occurrence of ECs in eastern regions is higher than in western regions. A majority of EC studies have focused on surface waters of the Haihe River and Pearl River watersheds due to their highly developed industries and intense human activity. Legislative and administrative regulation of ECs is lacking in China. To remove ECs, a number of technologies, such as absorption by activated carbon, membrane filtration technology, and advanced oxidation processes, have been researched. (letter)

  10. Environmental survey to assess viral contamination of air and surfaces in hospital settings.

    Science.gov (United States)

    Carducci, A; Verani, M; Lombardi, R; Casini, B; Privitera, G

    2011-03-01

    The presence of pathogenic viruses in healthcare settings represents a serious risk for both staff and patients. Direct viral detection in the environment poses significant technical problems and the indirect indicators currently in use suffer from serious limitations. The aim of this study was to monitor surfaces and air in hospital settings to reveal the presence of hepatitis C virus, human adenovirus, norovirus, human rotavirus and torque teno virus by nucleic acid assays, in parallel with measurements of total bacterial count and haemoglobin presence. In total, 114 surface and 62 air samples were collected. Bacterial contamination was very low (air was 282 cfu/m(3). Overall, 19 (16.7%) surface samples tested positive for viral nucleic acids: one for norovirus, one for human adenovirus and 17 (14.9%) for torque teno virus (TTV). Only this latter virus was directly detected in 10 air samples (16.1%). Haemoglobin was found on two surfaces. No relationship was found between viral, biochemical or bacterial indicators. The data obtained confirm the difficulty of assessing viral contamination using bacterial indicators. The frequent detection of TTV suggests its possible use as an indicator for general viral contamination of the environment. Copyright © 2010 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

  11. Microbiological quality control of single-walled carbon-nanotubes-coated surfaces experimentally contaminated

    International Nuclear Information System (INIS)

    Natalizi, T.; Frioni, A.; Passeri, D.; Pantanella, F.

    2013-01-01

    The emergence of new nanotechnologies involves the spreading of nanoparticles in various fields of human life. Nanoparticles in general and, more specifically, carbon nanotubes have been adopted for many practical approaches i.e.: coatings for medical devices, food process industry and drug delivery. Humans will be increasingly exposed to nanoparticles but the susceptibility of nanostructured materials to microbial colonization in process of manufacturing and storage has not been thoroughly considered. Therefore, the microbiological quality control of nanoparticles plays a pivotal role. Different analytical methods have been attempted for detecting bacterial population contaminating a surface, but no one can be considered fully appropriate. Here, BioTimer Assay (BTA) and conventional sonication followed by colony forming units method (S-CFU) were applied for microbiological quality control of single-walled carbon nanotubes (SWCNTs)-coated surfaces experimentally contaminated with Streptococcus mutans and Pseudomonas aeruginosa. Our results demonstrated that S-CFU is unreliable to actually determine the number of bacteria, contaminating abiotic surfaces, as it does not detach all adherent bacteria and kills part of the bacterial population. Instead, BTA is a reliable method to enumerate bacteria colonizing SWCNTs-coated surfaces and can be considered a useful tool for microbiological quality control of nanomaterials for human use.

  12. Emerging contaminants in surface waters in China—a short review

    Science.gov (United States)

    Yang, Guang; Fan, Maohong; Zhang, Guangming

    2014-07-01

    Emerging contaminants (ECs) have drawn attention to many countries due to their persistent input and potential threat to human health and the environment. This article reviews the current contamination sources and their status for surface waters in China. The contamination levels of ECs in surface waters are in the range ng L-1 to μg L-1 in China, apparently about the same as the situation in other countries. ECs enter surface water via runoff, drainage, rainfall, and wastewater treatment effluent. The frequency of occurrence of ECs increased rapidly from 2006 to 2011; a significant reason is the production and consumption of pharmaceuticals and personal care products. As for the distribution of EC pollution in China, the frequency of occurrence of ECs in eastern regions is higher than in western regions. A majority of EC studies have focused on surface waters of the Haihe River and Pearl River watersheds due to their highly developed industries and intense human activity. Legislative and administrative regulation of ECs is lacking in China. To remove ECs, a number of technologies, such as absorption by activated carbon, membrane filtration technology, and advanced oxidation processes, have been researched.

  13. Transport of contaminants by Arctic sea ice and surface ocean currents

    International Nuclear Information System (INIS)

    Pfirman, S.

    1995-01-01

    Sea ice and ocean currents transport contaminants in the Arctic from source areas on the shelves, to biologically active regions often more than a thousand kilometers away. Coastal regions along the Siberian margin are polluted by discharges of agricultural, industrial and military wastes in river runoff, from atmospheric deposition and ocean dumping. The Kara Sea is of particular concern because of deliberate dumping of radioactive waste, as well as the large input of polluted river water. Contaminants are incorporated in ice during suspension freezing on the shelves, and by atmospheric deposition during drift. Ice releases its contaminant load through brine drainage, surface runoff of snow and meltwater, and when the floe disintegrates. The marginal ice zone, a region of intense biological activity, may also be the site of major contaminant release. Potentially contaminated ice from the Kara Sea is likely to influence the marginal ice zones of the Barents and Greenland seas. From studies conducted to date it appears that sea ice from the Kara Sea does not typically enter the Beaufort Gyre, and thus is unlikely to affect the northern Canadian and Alaskan margins

  14. Camel meat quality in the slaughterhouse of Ouargla in Algeria. II. Bacterial surface contamination of carcasses

    Directory of Open Access Journals (Sweden)

    A. Benaissa

    2015-10-01

    Full Text Available To assess the microbiological quality of camel meat in the slaughterhouse of Ouargla District in Algeria, the bacterial surface contamination of 60 camel carcasses was investigated. Within an hour after slaughter, swabs were used to collect samples on three sites (thigh, flank and shoulder, just after skinning and before postmortem inspection. Germ rates varied depending on the carcasses and sampling sites. The predominant flora was the total aerobic mesophilic flora, whose contamination level was 2.8  log CFU/cm2 (i.e. 25% of the flora count, followed by enterobacteria with 2.4 log CFU/cm2 (21%, total coliforms with 2.2 log CFU/cm2 (20%, fecal coliforms with 2.0  log CFU/cm2 (18%, and staphylococci with 1.8 log CFU/cm2 (16%. Salmonella and Escherichia coli were detected on all the sampled sites of the carcasses. The camel meat of Ouargla slaughterhouse showed a high level of contamination by pathogenic bacteria (salmonellae and staphylococci. A high fecal contamination (E. coli was also present. Good hygiene practices need to be implemented at slaughter to reduce contaminations.

  15. Occurrence of perchloroethylene in surface water and fish in a river ecosystem affected by groundwater contamination.

    Science.gov (United States)

    Wittlingerová, Zdena; Macháčková, Jiřina; Petruželková, Anna; Zimová, Magdalena

    2016-03-01

    Long-term monitoring of the content of perchloroethylene (PCE) in a river ecosystem affected by groundwater contamination was performed at a site in the Czech Republic. The quality of surface water was monitored quarterly between 1994 and 2013, and fish were collected from the affected ecosystem to analyse the content of PCE in their tissue in 1998, 2011 and 2012. Concentrations of PCE (9-140 μg/kg) in the tissue of fish collected from the contaminated part of the river were elevated compared to the part of the river unaffected by the contamination (ND to 5 μg/kg PCE). The quality of surface water has improved as a result of groundwater remediation during the evaluated period. Before the remedial action, PCE concentrations ranged from 30 to 95 μg/L (1994-1997). Following commencement of remedial activities in September 1997, a decrease in the content of PCE in the surface water to 7.3 μg/L (1998) and further to 1 μg/L (2011) and 1.1 μg/L (2012) led to a progressive decrease in the average concentration of PCE in the fish muscle tissue from 79 μg/kg (1998) to 24 (2011) and 30 μg/kg (2012), respectively. It was determined that the bioconcentration of PCE does not have a linear dependence because the decrease in contamination in the fish muscle tissue is not directly proportional to the decrease in contamination in the river water. The observed average bioconcentration factors were 24 and 28 for the lower concentrations of PCE and 11 for the higher concentrations of PCE in the river. In terms of age, length and weight of the collected fish, weight had the greatest significance for bioconcentration, followed by the length, with age being evaluated as a less significant factor.

  16. Field emission and high voltage cleaning of particulate contaminants on extended metallic surfaces

    International Nuclear Information System (INIS)

    Tan, J.; Bonin, B.; Safa, H.

    1996-01-01

    The vacuum insulation properties of extended metallic surfaces depends strongly on their cleanliness. The usual technique to reduce electronic field emission from such surfaces consists in exposing them to very high electric fields during limited periods of time. This kind of processing also reduces the occurrence of vacuum breakdown. The processing of the surface is generally believed to be due to a thermomechanical destruction of the emitting sites, initiated by the emission itself. Comparison of the electric forces vs adherence forces which act on dust particles lying on the surface shows that the processing could also be due simply to the mechanical removal of the dust particles, with a subsequent reduction of field emission from the contaminated surface. (author)

  17. Substantiation of rate setting of surface contamination with amino acids, labelled with tritium

    International Nuclear Information System (INIS)

    Zhesko, T.V.

    1987-01-01

    For rate setting of surface contamination with the wide-spread biogenic tritium compounds-protein predecessors-experimental study of skin absorption and skin deposit of amino acids labelled with tritium is carried out on rats. While extrapolating data to people and calculating tolerable skin contamination with 3 H- amino acids, it is supposed that people arm skin, 100-500 cm 2 , has no defects and that the skin surface decontamination after radionuclide contact is carried out with a preparation, efficiency of which is not less than 97%. The value of tolerable skin absorption of tritium amino acids, being 110-550 MBq/year or 4.8 kBq/cm 2 per one working day, is calculated

  18. Portable instrumentation for quantitatively measuring radioactive surface contaminations, including 90Sr

    International Nuclear Information System (INIS)

    Brodzinski, R.L.

    1983-10-01

    In order to measure the effectiveness of decontamination efforts, a quantitative analysis of the radiocontamination is necessary, both before and after decontamination. Since it is desirable to release the decontaminated material for unrestricted use or disposal, the assay equipment must provide adequate sensitivity to measure the radioactivity at or below the release limit. In addition, the instrumentation must be capable of measuring all kinds of radiocontaminants including fission products, activation products, and transuranic materials. Finally, the survey instrumentation must be extremely versatile in order to assay the wide variety of contaminated surfaces in many environments, some of which may be extremely hostile or remote. This communication describes the development and application of portable instrumentation capable of quantitatively measuring most transuranics, activation products, and fission products, including 90 Sr, on almost any contaminated surface in nearly any location

  19. Longer Contact Times Increase Cross-Contamination of Enterobacter aerogenes from Surfaces to Food.

    Science.gov (United States)

    Miranda, Robyn C; Schaffner, Donald W

    2016-11-01

    Bacterial cross-contamination from surfaces to food can contribute to foodborne disease. The cross-contamination rate of Enterobacter aerogenes on household surfaces was evaluated by using scenarios that differed by surface type, food type, contact time (food types were watermelon, bread, bread with butter, and gummy candy. Surfaces (25 cm 2 ) were spot inoculated with 1 ml of inoculum and allowed to dry for 5 h, yielding an approximate concentration of 10 7 CFU/surface. Foods (with a 16-cm 2 contact area) were dropped onto the surfaces from a height of 12.5 cm and left to rest as appropriate. Posttransfer, surfaces and foods were placed in sterile filter bags and homogenized or massaged, diluted, and plated on tryptic soy agar. The transfer rate was quantified as the log percent transfer from the surface to the food. Contact time, food, and surface type all had highly significant effects (P food, while the least bacteria transferred to gummy candy (∼0.1 to 62%). Transfer of bacteria to bread (∼0.02 to 94%) was similar to transfer of bacteria to bread with butter (∼0.02 to 82%), and these transfer rates under a given set of conditions were more variable than with watermelon and gummy candy. The popular notion of the "five-second rule" is that food dropped on the floor and left there for foods (watermelon, bread, bread with butter, and gummy candy), four different contact times (food and the surface, are of equal or greater importance. Some transfer takes place "instantaneously," at times of <1 s, disproving the five-second rule. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  20. Evaluation of surface contamination based on certifiably traceable, internationally accreditable measurements

    International Nuclear Information System (INIS)

    Whitlock, G.D.

    1992-01-01

    National Accreditation and Measurement Service (NAMAS) adopted by the EUROMET agreement requires that the calibration of monitoring instruments be traceable internationally with the objective that radiation hazard assessment be improved. This objective is achieved for Tritium surface contamination by employing calibration sources and evaluation methods which comply with ISO standards including the measurement of activity removable by Volatilization as well as dust. Consideration should be given to organic binding of tritium in the skin with its implications in the event of litigation. (author)

  1. New miniaturized alpha/beta spectrometric system for the surface contamination monitoring and radon personal dosimeter

    International Nuclear Information System (INIS)

    Streil, T.; Oeser, V.; Holfeld, G.

    1998-01-01

    The heart of the new miniaturized alpha/beta spectroscopic system is a Smart Card MCA having a 12 bit resolution and a 32 bit memory for each channel with the size of a cheque card. The system consists of a single or up to 12 alpha spectrometers in a battery powered casing with connectors for direct detector/amplifier module plugging. Surface contamination in the order of 1 Bq/cm 2 of 239 Pu can be measured. (M.D.)

  2. Carbapenem-Resistant Acinetobacter baumannii: Concomitant Contamination of Air and Environmental Surfaces.

    Science.gov (United States)

    Shimose, Luis A; Masuda, Eriko; Sfeir, Maroun; Berbel Caban, Ana; Bueno, Maria X; dePascale, Dennise; Spychala, Caressa N; Cleary, Timothy; Namias, Nicholas; Kett, Daniel H; Doi, Yohei; Munoz-Price, L Silvia

    2016-07-01

    OBJECTIVE To concomitantly determine the differential degrees of air and environmental contamination by Acinetobacter baumannii based on anatomic source of colonization and type of ICU layout (single-occupancy vs open layout). DESIGN Longitudinal prospective surveillance study of air and environmental surfaces in patient rooms. SETTING A 1,500-bed public teaching hospital in Miami, Florida. PATIENTS Consecutive A. baumannii-colonized patients admitted to our ICUs between October 2013 and February 2014. METHODS Air and environmental surfaces of the rooms of A. baumannii-colonized patients were sampled daily for up to 10 days. Pulsed-field gel electrophoresis (PFGE) was used to type and match the matching air, environmental, and clinical A. baumannii isolates. RESULTS A total of 25 A. baumannii-colonized patients were identified during the study period; 17 were colonized in the respiratory tract and 8 were colonized in the rectum. In rooms with rectally colonized patients, 38.3% of air samples were positive for A. baumannii; in rooms of patients with respiratory colonization, 13.1% of air samples were positive (P=.0001). In rooms with rectally colonized patients, 15.5% of environmental samples were positive for A. baumannii; in rooms of patients with respiratory colonization, 9.5% of environmental samples were positive (P=.02). The rates of air contamination in the open-layout and single-occupancy ICUs were 17.9% and 21.8%, respectively (P=.5). Environmental surfaces were positive in 9.5% of instances in open-layout ICUs versus 13.4% in single-occupancy ICUs (P=.09). CONCLUSIONS Air and environmental surface contaminations were significantly greater among rectally colonized patients; however, ICU layout did not influence the rate of contamination. Infect Control Hosp Epidemiol 2016;37:777-781.

  3. Device for determining the gross weight, dose rate, surface contamination and/or nuclide inventory

    International Nuclear Information System (INIS)

    1987-01-01

    Barrels with low nuclide inventories (about 1E6 Bq) and with high inventories (1E13 Bq) are inspected with the barrel inspection system. The system provides a rotating plate, which is part of some scales and a measuring sensor arrangement for this purpose. The surface contamination and nuclide inventories of the 200 litre barrels can be calculated from the weight and radiation detector values. (DG) [de

  4. Chemical disinfection of non-porous inanimate surfaces experimentally contaminated with four human pathogenic viruses.

    OpenAIRE

    Sattar, S. A.; Springthorpe, V. S.; Karim, Y.; Loro, P.

    1989-01-01

    The chemical disinfection of virus-contaminated non-porous inanimate surfaces was investigated using coxsackievirus B3, adenovirus type 5, parainfluenza virus type 3 and coronavirus 229E as representatives of important nosocomial viral pathogens. A 10 microliter amount of the test virus, suspended in either faeces or mucin, was placed onto each stainless steel disk (about 1 cm in diameter) and the inoculum allowed to dry for 1 h under ambient conditions. Sixteen disinfectant formulations were...

  5. Multiple containment for LSA [low specific activity] and SCO [surface contaminated objects] wastes

    International Nuclear Information System (INIS)

    Burgess, M.H.

    1993-09-01

    Radioactive wastes are generally transported in the form of Low Specific Activity (LSA) materials or Surface Contaminated Objects (SCO). This report proposes that a method of acknowledging the beneficial effects of multiple containment for such wastes should be written into the 1996 Edition of the IAEA Transport Regulations. Experience used to assess risks from on-site movements of radioactive material in the UK can be applied to develop safety arguments justifying the alleviation of off-site transport risks. (UK)

  6. Model for the assessment of surface radionuclide 210 Pb contamination indoors due to presence of radon

    International Nuclear Information System (INIS)

    Mrdja, D.; Bikit, I.; Forkapic, S.

    2009-01-01

    The model is based on the fact that the change of indoor radon concentration, which periodically enters the room, affects only on radioactive decay and the inserted amount of radon in each impact, but not on its diffusion out, i.e. escape from the room. The aim of the model is to assess the surface contamination of the room by lead 210 Pb. (author) [sr

  7. Risk assessment based on current release standards for radioactive surface contamination

    International Nuclear Information System (INIS)

    Chen, S.Y.

    1993-09-01

    Standards for uncontrolled releases of radioactive surface contamination have been in existence in the United States for about two decades. Such standards have been issued by various agencies, including the US Department of Energy. This paper reviews the technical basis of published standards, identifies areas in need of revision, provides risk interpretations based on current technical knowledge and the regulatory environment, and offers suggestions for improvements

  8. Detecting buried radium contamination using soil-gas and surface-flux radon meaurements

    International Nuclear Information System (INIS)

    Karp, K.E.

    1988-06-01

    The Technical Measurements Center (TMC) has investigated the effectiveness of using radon soil-gas under surface-flux measurments to locate radium contamination that is buried sufficiently deep to be undetectable by surface gamma methods. At the first test site studied, an indication of a buried source was revealed by mapping anomalous surface-flux and soil-gas concentrations in the near surface overburden. The mapped radon anomalies were found to correspond in rough outline to the shape of the areal extent of the deposit as determined by borehole gamma-ray logs. The 5.9pCi/g radium deposit, buried 2 feet below the surface, went undetected by conventional surface gamma measurements. Similar results were obtained at the second test site where radon and conventional surface gamma measurements were taken in an area having radium concentrations ranging from 13.3 to 341.0 pCi/g at a depth of 4 feet below the surface. The radon methods were found to have a detection limit for buried radium lower than that of the surface gamma methods, as evidenced by the discovery of the 13.3 pCi/g deposit which went undetected by the surface gamma methods. 15 refs., 33 figs., 8 tabs

  9. Trench 'bathtubbing' and surface plutonium contamination at a legacy radioactive waste site.

    Science.gov (United States)

    Payne, Timothy E; Harrison, Jennifer J; Hughes, Catherine E; Johansen, Mathew P; Thiruvoth, Sangeeth; Wilsher, Kerry L; Cendón, Dioni I; Hankin, Stuart I; Rowling, Brett; Zawadzki, Atun

    2013-01-01

    Radioactive waste containing a few grams of plutonium (Pu) was disposed between 1960 and 1968 in trenches at the Little Forest Burial Ground (LFBG), near Sydney, Australia. A water sampling point installed in a former trench has enabled the radionuclide content of trench water and the response of the water level to rainfall to be studied. The trench water contains readily measurable Pu activity (~12 Bq/L of (239+240)Pu in 0.45 μm-filtered water), and there is an associated contamination of Pu in surface soils. The highest (239+240)Pu soil activity was 829 Bq/kg in a shallow sample (0-1 cm depth) near the trench sampling point. Away from the trenches, the elevated concentrations of Pu in surface soils extend for tens of meters down-slope. The broader contamination may be partly attributable to dispersion events in the first decade after disposal, after which a layer of soil was added above the trenched area. Since this time, further Pu contamination has occurred near the trench-sampler within this added layer. The water level in the trench-sampler responds quickly to rainfall and intermittently reaches the surface, hence the Pu dispersion is attributed to saturation and overflow of the trenches during extreme rainfall events, referred to as the 'bathtub' effect.

  10. Trench ‘Bathtubbing’ and Surface Plutonium Contamination at a Legacy Radioactive Waste Site

    Science.gov (United States)

    2013-01-01

    Radioactive waste containing a few grams of plutonium (Pu) was disposed between 1960 and 1968 in trenches at the Little Forest Burial Ground (LFBG), near Sydney, Australia. A water sampling point installed in a former trench has enabled the radionuclide content of trench water and the response of the water level to rainfall to be studied. The trench water contains readily measurable Pu activity (∼12 Bq/L of 239+240Pu in 0.45 μm-filtered water), and there is an associated contamination of Pu in surface soils. The highest 239+240Pu soil activity was 829 Bq/kg in a shallow sample (0–1 cm depth) near the trench sampling point. Away from the trenches, the elevated concentrations of Pu in surface soils extend for tens of meters down-slope. The broader contamination may be partly attributable to dispersion events in the first decade after disposal, after which a layer of soil was added above the trenched area. Since this time, further Pu contamination has occurred near the trench-sampler within this added layer. The water level in the trench-sampler responds quickly to rainfall and intermittently reaches the surface, hence the Pu dispersion is attributed to saturation and overflow of the trenches during extreme rainfall events, referred to as the ‘bathtub’ effect. PMID:24256473

  11. Detection of fecal contamination on beef meat surfaces using handheld fluorescence imaging device (HFID)

    Science.gov (United States)

    Oh, Mirae; Lee, Hoonsoo; Cho, Hyunjeong; Moon, Sang-Ho; Kim, Eun-Kyung; Kim, Moon S.

    2016-05-01

    Current meat inspection in slaughter plants, for food safety and quality attributes including potential fecal contamination, is conducted through by visual examination human inspectors. A handheld fluorescence-based imaging device (HFID) was developed to be an assistive tool for human inspectors by highlighting contaminated food and food contact surfaces on a display monitor. It can be used under ambient lighting conditions in food processing plants. Critical components of the imaging device includes four 405-nm 10-W LEDs for fluorescence excitation, a charge-coupled device (CCD) camera, optical filter (670 nm used for this study), and Wi-Fi transmitter for broadcasting real-time video/images to monitoring devices such as smartphone and tablet. This study aimed to investigate the effectiveness of HFID in enhancing visual detection of fecal contamination on red meat, fat, and bone surfaces of beef under varying ambient luminous intensities (0, 10, 30, 50 and 70 foot-candles). Overall, diluted feces on fat, red meat and bone areas of beef surfaces were detectable in the 670-nm single-band fluorescence images when using the HFID under 0 to 50 foot-candle ambient lighting.

  12. Mathematical simulation of sediment and contaminant transport in surface waters. Annual report, October 1977--September 1978

    International Nuclear Information System (INIS)

    Onishi, Y.; Arnold, E.M.; Serne, R.J.; Cowan, C.E.; Thompson, F.L.; Mayer, D.W.

    1979-01-01

    Various pathways exist for exposure of humans and biota to radioactive materials released from nuclear facilities. Hydrologic transport (liquid pathway) is one element in the evaluation of the total radiation dose to man. Mathematical models supported by well-planned field data collection programs can be useful tools in assessing the hydrologic transport and ultimate fate of radionuclides. Radionuclides with high distribution coefficients or radionuclides in surface waters with high suspended sediment concentrations are, to a great extent, adsorbed by river and marine sediments. Thus, otherwise dilute contaminants are concentrated. Contaminated sediments may be deposited on the river and ocean beds creating a significant pathway to man. Contaminated bed sediment in turn may become a long-term source of pollution through desorption and resuspension. In order to assess migration and accumulation of radionuclides in surface waters, mathematical models must correctly simulate essential mechanisms of radionuclide transport. The objectives of this study were: (1) to conduct a critical review of (a) radionuclide transport models as well as sediment transport and representative water quality models in rivers, estuaries, oceans, lakes, and reservoirs, and (b) adsorption and desorption mechanisms of radionuclides with sediments in surface waters; (2) to synthesize a mathematical model capable of predicting short- and long-term transport and accumulation of radionuclides in marine environments

  13. Mitigation of cesium and cobalt contamination on the surfaces of RAM packages

    International Nuclear Information System (INIS)

    Krumhansl, J.; Bonhomme, F.; McConnell, P.; Kapoor, A.

    2004-01-01

    Techniques for mitigating the adsorption of 137 Cs and 60 Co on metal surfaces (e.g., RAM packages) exposed to contaminated water (e.g., spent-fuel pools) has been developed and experimentally verified. The techniques are also effective in removing some of the 60 Co and 137 Cs that may have been adsorbed on the surfaces after removal from the contaminated water. The principle for the 137 Cs mitigation technique is based upon ion-exchange processes. In contrast, 60 Co contamination primarily resides in minute particles of CRUD that become lodged on cask surfaces. CRUD is an insoluble Fe-Ni-Cr oxide that forms colloidal-sized particles as stainless steels corrode. Because of the similarity between Ni +2 and Co +2 , CRUD is able to scavenge and retain traces of cobalt as it forms. A number of organic compounds have a great specificity for combining with nickel and cobalt. Ongoing research is investigating the effectiveness of chemical complexing agent, EDTA, with regard to its ability to dissolve the host phase (CRUD) thereby liberating the entrained 60Co into a solution where it can be rinsed away

  14. Linking otolith microchemistry and surface water contamination from natural gas mining.

    Science.gov (United States)

    Keller, David H; Zelanko, Paula M; Gagnon, Joel E; Horwitz, Richard J; Galbraith, Heather S; Velinsky, David J

    2018-09-01

    Unconventional natural gas drilling and the use of hydraulic fracturing technology have expanded rapidly in North America. This expansion has raised concerns of surface water contamination by way of spills and leaks, which may be sporadic, small, and therefore difficult to detect. Here we explore the use of otolith microchemistry as a tool for monitoring surface water contamination from generated waters (GW) of unconventional natural gas drilling. We exposed Brook Trout in the laboratory to three volumetric concentrations of surrogate generated water (SGW) representing GW on day five of drilling. Transects across otolith cross-sections were analyzed for a suite of elements by LA-ICP-MS. Brook Trout exposed to a 0.01-1.0% concentration of SGW for 2, 15, and 30 days showed a significant (p waters and provide support for the use of this technique in natural habitats. To our knowledge, this is the first demonstration of how trace elements in fish otoliths may be used to monitor for surface water contamination from GW. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Surface Sampling Collection and Culture Methods for Escherichia coli in Household Environments with High Fecal Contamination.

    Science.gov (United States)

    Exum, Natalie G; Kosek, Margaret N; Davis, Meghan F; Schwab, Kellogg J

    2017-08-22

    Empiric quantification of environmental fecal contamination is an important step toward understanding the impact that water, sanitation, and hygiene interventions have on reducing enteric infections. There is a need to standardize the methods used for surface sampling in field studies that examine fecal contamination in low-income settings. The dry cloth method presented in this manuscript improves upon the more commonly used swabbing technique that has been shown in the literature to have a low sampling efficiency. The recovery efficiency of a dry electrostatic cloth sampling method was evaluated using Escherichia coli and then applied to household surfaces in Iquitos, Peru, where there is high fecal contamination and enteric infection. Side-by-side measurements were taken from various floor locations within a household at the same time over a three-month period to compare for consistency of quantification of E. coli bacteria. The dry cloth sampling method in the laboratory setting showed 105% (95% Confidence Interval: 98%, 113%) E. coli recovery efficiency off of the cloths. The field application demonstrated strong agreement of side-by-side results (Pearson correlation coefficient for dirt surfaces was 0.83 ( p samples (Pearson (0.53, p method can be utilized in households with high bacterial loads using either continuous (quantitative) or categorical (semi-quantitative) data. The standardization of this low-cost, dry electrostatic cloth sampling method can be used to measure differences between households in intervention and non-intervention arms of randomized trials.

  16. Study of luminous phenomena observed on contaminated metallic surfaces submitted to high RF fields

    International Nuclear Information System (INIS)

    Maissa, S.; Junquera, T.; Fouaidy, M.; Le Goff, A.; Bonin, B.; Luong, M.; Safa, H.; Tan, J.

    1995-01-01

    The RF field emission from a sample subjected to high RF fields in a copper cavity has been investigated. The study is focused on the luminous emissions occurring on the RF surface simultaneously with the electron emission. The optical apparatus attached to the cavity permits to observe the evolution of the emitters and the direct effects of the surface conditioning. Also, the parameters of the emitted radiation (intensity, glowing duration, spectral distribution) may provide additional informations on the field emission phenomena. Some results concerning samples intentionally contaminated with particles (metallic or dielectric) are presented. (K.A.)

  17. Surface and subsurface characterization of uranium contamination at the Fernald environmental management site

    International Nuclear Information System (INIS)

    Schilk, A.J.; Perkins, R.W.; Abel, K.H.; Brodzinski, R.L.

    1993-04-01

    The past operations of uranium production and support facilities at several Department of Energy (DOE) sites have occasionally resulted in the local contamination of some surface and subsurface soils, and the three-dimensional distribution of the uranium at these sites must be thoroughly characterized before any effective remedial protocols can be established. To this end, Pacific Northwest Laboratory (PNL) has been tasked by the DOE's Office of Technology Development with adapting, developing, and demonstrating technologies for the measurement of uranium in surface and subsurface soils at the Fernald Uranium in Soils Integrated Demonstration site. These studies are detailed in this report

  18. Methane Bubbles Transport Particles From Contaminated Sediment to a Lake Surface

    Science.gov (United States)

    Delwiche, K.; Hemond, H.

    2017-12-01

    Methane bubbling from aquatic sediments has long been known to transport carbon to the atmosphere, but new evidence presented here suggests that methane bubbles also transport particulate matter to a lake surface. This transport pathway is of particular importance in lakes with contaminated sediments, as bubble transport could increase human exposure to toxic metals. The Upper Mystic Lake in Arlington, MA has a documented history of methane bubbling and sediment contamination by arsenic and other heavy metals, and we have conducted laboratory and field studies demonstrating that methane bubbles are capable of transporting sediment particles over depths as great as 15 m in Upper Mystic Lake. Methane bubble traps were used in-situ to capture particles adhered to bubble interfaces, and to relate particle mass transport to bubble flux. Laboratory studies were conducted in a custom-made 15 m tall water column to quantify the relationship between water column height and the mass of particulate transport. We then couple this particle transport data with historical estimates of ebullition from Upper Mystic Lake to quantify the significance of bubble-mediated particle transport to heavy metal cycling within the lake. Results suggest that methane bubbles can represent a significant pathway for contaminated sediment to reach surface waters even in relatively deep water bodies. Given the frequent co-occurrence of contaminated sediments and high bubble flux rates, and the potential for human exposure to heavy metals, it will be critical to study the significance of this transport pathway for a range of sediment and contaminant types.

  19. A simplified ALARA approach to demonstration of compliance with surface contaminated object regulatory requirements

    International Nuclear Information System (INIS)

    Pope, R.B.; Shappert, L.B.; Michelhaugh, R.D.; Boyle, R.W.; Cook, J.C.

    1998-02-01

    The US Department of Transportation (DOT) and the US Nuclear Regulatory Commission (NRC) have jointly prepared a comprehensive set of draft guidance for consignors and inspectors to use when applying the newly imposed regulatory requirements for low specific activity (LSA) material and surface contaminated objects (SCOs). The guidance is being developed to facilitate compliance with the new LSA material and SCO requirements, not to impose additional requirements. These new requirements represent, in some areas, significant departures from the manner in which packaging and transportation of these materials and objects were previously controlled. On occasion, it may be appropriate to use conservative approaches to demonstrate compliance with some of the requirements, ensuring that personnel are not exposed to radiation at unnecessary levels, so that exposures are kept as low as reasonably achievable (ALARA). In the draft guidance, one such approach would assist consignors preparing a shipment of a large number of SCOs in demonstrating compliance without unnecessarily exposing personnel. In applying this approach, users need to demonstrate that four conditions are met. These four conditions are used to categorize non-activated, contaminated objects as SCO-2. It is expected that, by applying this approach, it will be possible to categorize a large number of small contaminated objects as SCO-2 without the need for detailed, quantitative measurements of fixed, accessible contamination, or of total (fixed and non-fixed) contamination on inaccessible surfaces. The method, which is based upon reasoned argument coupled with limited measurements and the application of a sum of fractions rule, is described and examples of its use are provided

  20. Metals Accumulation and Leaf Surface Anatomy of Murdannia spectabilis Growing in Zn/Cd Contaminated Soil

    Directory of Open Access Journals (Sweden)

    Ladawan Rattanapolsan

    2013-07-01

    Full Text Available Murdannia spectabilis (Kurz Faden was identified as a Zn/Cd hyperaccumulative plant. Leaf surface anatomy of the plant growing in non-contaminated soil (control and Zn/Cd contaminated soil,was studied and compared by a light microscopy and scanning electron microscopy combined with Energy-dispersive X-ray spectroscopy(SEM/EDS. The similarities were reticulate cuticle on epidermises, uniform polygonal cell, stomatal arrangement in six surrounding subsidiary cells, and submarginal sclerenchyma. The dissimilarities were uniserate trichomes spreading on both adaxial and abaxial epidermis of the plants growing in non-contaminated soil, whereas the uniserate trichomes were only on the submarginal-adaxial epidermis of the control plants. The trichomes on leaves of the plants growing in non-contaminated soil were found to have both uniseriate non-glandular and uniseriate glandular trichomes;whereas, leaves of the plants growing in the contaminated soil were merely non-glandular trichomes. The different shape and location of trichomes, the number of stomata and trichome indicated the effect of Zn and Cd on M. spectabilis. The higher percentages of Zn and Cd in the vascular bundle than in the cross section and epidermis areas showed both solutes could move along each route, with diffusion through the symplast and apoplast. The increase of Ca in M. spectabilis growing in Zn/Cd contaminated soil corresponded to the Zn and Cd distributed in the leaves. Zn K-edge and S K-edge XANES spectra proposed that Zn2+ ions were accumulated and/or adsorbed on the epidermis of the tuber, and then absorbed into the root and transport to the xylem. The double peaks of Zn-cysteine in the leaf samples proposed the metal sequestration was by sulphur proteins.

  1. Limits determination of microbial contamination present on surfaces from a pharmaceutical microbiology district reference laboratory

    Directory of Open Access Journals (Sweden)

    Natalia Charry

    2016-06-01

    Full Text Available Context: The bioburden present on the pharmaceutical microbiology laboratory’s surfaces, may increase the risk of cross-contamination when analytical tests are being carried out; periodic monitoring allows to set limits that reduce the risk. Aims: To determinate the limits of bioburden present on seven surfaces of the pharmaceutical microbiology laboratory, after the cleaning and disinfection process. Methods: The swabbing method was used for sampling. With a 25 cm2 stencil and a sterile swab, a sample was taken, passing the swab over five points of every surface chosen. A total aerobic microbial count and a total yeast and mold count was done. Finally, the average and the standard deviation of the counts was obtained. Results: The average from the counts obtained on each surface selected for the study, were below the recommended limits by international entities like the World Health Organization and the European Union, between others; also, the results generated in this study, allow to classify the biosafety cabinet as an ISO 5 area and the other areas as ISO 7. Conclusions: Bioburden levels on the tested surfaces are considered low, reducing the risk of cross-contamination, which could have a negative impact on laboratory’s activities. Also, it follows that disinfectant concentration used, is effectively.

  2. Radon-induced surface contaminations in neutrinoless double beta decay and dark matter experiments

    International Nuclear Information System (INIS)

    Pattavina, L.

    2011-01-01

    In experiments looking for rare events, like neutrinoless double beta decay (DBD0ν) and dark matter search (DM), one of the main issues is to increase the experimental sensitivity through the material selection and production. The background contribution coming from the materials used for the detector realization has to be minimized. Moreover the net reduction of the background produced by the bulk part of the apparatus has raised concerns about the background contribution coming from the surfaces. Many procedures and techniques were developed during the last years in order to remove and to minimize the presence of possible contaminants on detector surfaces. To succeed in this strategy a big effort was put in defining all possible mechanisms that lead to surface contaminations, as well as specific cleaning procedures, which are able to reduce and control the surface radioactivity. The presence in air and gases of possible radioactive elements that can stick on the detector surfaces can lead to a recontamination process that will vanish all the applied cleaning procedures. Here is presented and analyzed the contribution to the background of rare events experiments like CUORE experiment (DBD0ν) and EDELWEISS experiment (DM) produced by an exposure of their detector components to a big activity of 222 Rn, radioactive daughter isotope from the 238 U chain. (author)

  3. Determination of the external contamination and cross-contamination by cytotoxic drugs on the surfaces of vials available on the Swiss market.

    Science.gov (United States)

    Fleury-Souverain, Sandrine; Nussbaumer, Susanne; Mattiuzzo, Marc; Bonnabry, Pascal

    2014-04-01

    The external contamination and cross-contamination by cytotoxic drugs on the surface (outside and septum) of 133 vials from various manufacturers and available on the Swiss market were evaluated. All of the tested vials contained one of the following active ingredients: cyclophosphamide, cytarabine, doxorubicin, epirubicin, etoposide phosphate, gemcitabine, ifosfamide, irinotecan, methotrexate or vincristine. The validated wiping liquid chromatography-mass spectrometry method used in this study allowed for the simultaneous determination of these 10 cytotoxic drugs in less than 30 min. External contamination by cytotoxic drugs was detected on 63% of tested vials (outside and septum). The highest contamination level was observed on etoposide phosphate vials with 1896.66 ng of active ingredient on the outside of the vial. Approximately 20% of the contaminated vials had greater than 10 ng of cytotoxic drugs. Chemical contamination on the septum was detected on 38% of the vials. No contamination or very low levels of cytotoxic drugs, less than 1 ng per vial, were detected on the vials protected by plastic shrink-wrap. Traces of cytotoxic drugs different from the active ingredient were detected on 35% of the tested vials. Handling cytotoxic vials with gloves and having a procedure for the decontamination of vials are of the utmost importance for reducing exposure to cytotoxic drugs. Moreover, manufacturers must improve their procedures to provide products free from any contamination.

  4. Accuracy Analysis of a Robotic Radionuclide Inspection and Mapping System for Surface Contamination

    International Nuclear Information System (INIS)

    Mauer, Georg F.; Kawa, Chris

    2008-01-01

    The mapping of localized regions of radionuclide contamination in a building can be a time consuming and costly task. Humans moving hand-held radiation detectors over the target areas are subject to fatigue. A contamination map based on manual surveys can contain significant operator-induced inaccuracies. A Fanuc M16i light industrial robot has been configured for installation on a mobile aerial work platform, such as a tall forklift. When positioned in front of a wall or floor surface, the robot can map the radiation levels over a surface area of up to 3 m by 3 m. The robot's end effector is a commercial alpha-beta radiation sensor, augmented with range and collision avoidance sensors to ensure operational safety as well as to maintain a constant gap between surface and radiation sensors. The accuracy and repeatability of the robotically conducted contamination surveys is directly influenced by the sensors and other hardware employed. This paper presents an in-depth analysis of various non-contact sensors for gap measurement, and the means to compensate for predicted systematic errors that arise during the area survey scans. The range sensor should maintain a constant gap between the radiation counter and the surface being inspected. The inspection robot scans the wall surface horizontally, moving down at predefined vertical intervals after each scan in a meandering pattern. A number of non-contact range sensors can be employed for the measurement of the gap between the robot end effector and the wall. The nominal gap width was specified as 10 mm, with variations during a single scan not to exceed ± 2 mm. Unfinished masonry or concrete walls typically exhibit irregularities, such as holes, gaps, or indentations in mortar joints. These irregularities can be sufficiently large to indicate a change of the wall contour. The responses of different sensor types to the wall irregularities vary, depending on their underlying principles of operation. We explored

  5. Radioactive contamination in environment and food in Poland in 1992

    International Nuclear Information System (INIS)

    Grabowski, D.; Muszynski, W.; Petrykowska, M.; Rubel, B.; Smagala, G.; Wilgos, J.

    1993-01-01

    The level analysis of the level of radioactive contamination in environment and food samples was carried out in Poland in 1992. The results were compared to the data from 1985-1991 period. Since the Chernobyl accident gradual decrease of contamination level has been stated. The gamma dose rate and the contamination of air, fallout, tap and surface water were at the level of 1985. Still higher contamination level of cesium isotopes in soil has been reported and as a consequence food contamination was higher particularly the animal food. Actually, the source of additional dose is ingestion of artificial isotopes with food as a result of food contamination. The average effective dose equivalent, due to the contaminated food consumption, was estimated at the level 15 μSv for a Pole in 1992. (author). 13 refs, 6 figs, 20 tabs

  6. Atmospheric pressure plasma cleaning of contamination surfaces. 1997 mid-year progress report

    International Nuclear Information System (INIS)

    Hicks, R.; Selwyn, G.S.

    1997-01-01

    'Goals of the project are to (1) identify the key physics and chemistry underlying the use of high pressure plasmas for etching removal of actinides and actinide surrogates; and (2) identify key surface reactions and plasma physics necessary for optimization of the atmospheric pressure plasma jet. Technical description of the work decommissioning of transuranic waste (TRU) into low-level radioactive waste (LLW) represents the largest cleanup cost associated with the nuclear weapons complex. This work is directed towards developing a low-cost plasma technology capable of converting TRU into LLW, based upon highly selective plasma etching of plutonium and other actinides from contaminated surfaces. In this way, only the actinide material is removed, leaving the surface less contaminated. The plasma etches actinide material by producing a volatile halide compound, which may be efficiently trapped using filters. To achieve practical, low-cost operation of a plasma capable of etching actinide materials, the authors have developed a y-mode, resonant-cavity, atmospheric pressure plasma jet (APPJ). In contrast to conventional, low pressure plasmas, the APPJ produces a purely-chemical effluent free of ions, and so achieves very high selectivity and produces negligible damage to the surface. Since the jet operates outside a chamber, many nuclear wastes may be treated including machinery, duct-work, concrete and other building materials. In some cases, it may be necessary to first remove paint from contaminated surfaces using a plasma selective for that surface, then to switch to the actinide etching chemistry for removal of actinide contamination. The goal of this work is to develop the underlying science required for maturation of this technology and to establish early version engineering prototypes. Accomplishments to Date The authors have made significant progress in this program. The work conducted jointly at Los Alamos and at UCLA. This has been facilitated by exchange

  7. Atmospheric pressure plasma cleaning of contamination surfaces. 1997 mid-year progress report

    Energy Technology Data Exchange (ETDEWEB)

    Selwyn, G.S. [Los Alamos National Lab., NM (US); Hicks, R. [Univ. of California, Los Angeles, CA (US)

    1997-06-01

    'Goals of the project are to (1) identify the key physics and chemistry underlying the use of high pressure plasmas for etching removal of actinides and actinide surrogates; and (2) identify key surface reactions and plasma physics necessary for optimization of the atmospheric pressure plasma jet. Technical description of the work decommissioning of transuranic waste (TRU) into low-level radioactive waste (LLW) represents the largest cleanup cost associated with the nuclear weapons complex. This work is directed towards developing a low-cost plasma technology capable of converting TRU into LLW, based upon highly selective plasma etching of plutonium and other actinides from contaminated surfaces. In this way, only the actinide material is removed, leaving the surface less contaminated. The plasma etches actinide material by producing a volatile halide compound, which may be efficiently trapped using filters. To achieve practical, low-cost operation of a plasma capable of etching actinide materials, the authors have developed a y-mode, resonant-cavity, atmospheric pressure plasma jet (APPJ). In contrast to conventional, low pressure plasmas, the APPJ produces a purely-chemical effluent free of ions, and so achieves very high selectivity and produces negligible damage to the surface. Since the jet operates outside a chamber, many nuclear wastes may be treated including machinery, duct-work, concrete and other building materials. In some cases, it may be necessary to first remove paint from contaminated surfaces using a plasma selective for that surface, then to switch to the actinide etching chemistry for removal of actinide contamination. The goal of this work is to develop the underlying science required for maturation of this technology and to establish early version engineering prototypes. Accomplishments to Date The authors have made significant progress in this program. The work conducted jointly at Los Alamos and at UCLA. This has been facilitated by

  8. Using Contaminant Transport Modeling to Determine Historical Discharges at the Surface

    Science.gov (United States)

    Fogwell, T. W.

    2013-12-01

    When it is determined that a contaminated site needs to be remediated, the issue of who is going to pay for that remediation is an immediate concern. This means that there needs to be a determination of who the responsible parties are for the existing contamination. Seldom is it the case that records have been made and kept of the surface contaminant discharges. In many cases it is possible to determine the relative amount of contaminant discharge at the surface of the various responsible parties by employing a careful analysis of the history of contaminant transport through the surface, through the vadose zone, and within the saturated zone. The process begins with the development of a dynamic conceptual site model that takes into account the important features of the transport of the contaminants through the vadose zone and in the groundwater. The parameters for this model can be derived from flow data available for the site. The resulting contaminant transport model is a composite of the vadose zone transport model, together with the saturated zone (groundwater) flow model. Any calibration of the model should be carefully employed in order to avoid using information about the conclusions of the relative discharge amounts of the responsible parties in determining the calibrated parameters. Determination of the leading edge of the plume is an important first step. It is associated with the first discharges from the surface of the site. If there were several discharging parties at the same time, then it is important to establish a chemical or isotopic signature of the chemicals that were discharged. The time duration of the first discharger needs to be determined as accurately as possible in order to establish the appropriate characterization of the leading portion of the resulting plume in the groundwater. The information about the first discharger and the resulting part of the plume associated with this discharger serves as a basis for the determination of the

  9. Uptake of radionuclides by wheat roots with respect to location of contamination below the surface

    International Nuclear Information System (INIS)

    Suvornmongkhol, Narumon.

    1996-01-01

    The behaviour of 85 Sr, 137 Cs, 54 Mn and 60 Co in terms of plant availability in near surface soil and their root uptake was studied as a function of the location of contamination in the soil profile. Wheat (Triticum aestivum) was employed and the study programme involved both column and hydroponic studies. In the column studies, columns were packed with sandy soil, and either homogeneously or discretely contaminated with the radionuclides, and the water table maintained manually at 3 cm from the bottom. In the discrete contamination, the location of contamination was varied (0-5, 25-30 or 45-50 cm from the top). Wheat plants were grown to maturity in these columns, and harvested at different growth stages to examine radioactivity uptake and its subsequent translocation within the plants. The movement of radionuclides within the soil as well as the soil physicochemical properties were also investigated. The short term uptake kinetics of the hydroponically grown plants during ontogenesis were also studied, both with excised roots and intact plants. The excised root experiment was aimed at investigating the radionuclide by roots of different orders. (author)

  10. Occurrence and behavior of emerging contaminants in surface water and a restored wetland.

    Science.gov (United States)

    Matamoros, Víctor; Arias, Carlos A; Nguyen, Loc Xuan; Salvadó, Victòria; Brix, Hans

    2012-08-01

    Pollution mitigation is an important target for restored wetlands, and although there is much information in relation to nutrient removal, little attention has been paid to emerging contaminants. This paper reports on the occurrence and attenuation capacity of 17 emerging contaminants in a restored wetland and two rivers in North-East Denmark. The compounds belong to the groups of pharmaceuticals, fragrances, antiseptics, fire retardants, pesticides, and plasticizers. Concentrations in surface waters ranged from 2 to 1476 ng L(-1). The compounds with the highest concentrations were diclofenac, 2-methyl-4-chlorophenoxyacetic acid (MCPA), caffeine, and tris(2-chloroethyl) phosphate (TCEP). The herbicide concentrations increased after a rain-fall event, demonstrating the agricultural run-off origin of these compounds, whereas the concentration of the other emerging contaminants was rather conservative. The mitigation capacity of the restored wetland for the compounds ranged from no attenuation to 84% attenuation (19% on average). Hence, restored wetlands may be considered as a feasible alternative for mitigating emerging contaminants from river waters. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Resistance to disinfection of a polymicrobial association contaminating the surface of elastomeric dental impressions.

    Science.gov (United States)

    Giammanco, Giovanni M; Melilli, Dario; Rallo, Antonio; Pecorella, Sonia; Mammina, Caterina; Pizzo, Giuseppe

    2009-04-01

    The aim of this study was to evaluate the ability to resist disinfection of a polymicrobial association contaminating the surface of dental impressions obtained with two different elastomers: a polyether (Impregum) and an addition-polymerized silicone (Elite). Impressions were contaminated with a mixture of three biofilm-forming microorganisms (Staphylococcus aureus, Pseudomonas aeruginosa and Candida albicans) and disinfected immediately after contamination, or after microbial layers were allowed to develop during a six-hour storage. Two commercial disinfectants were tested: MD 520 containing 0.5% glutaraldehyde and Sterigum Powder without glutaraldehyde. Residual contamination was recovered by mechanical rinsing immediately after disinfection and after a six-hour storage of disinfected impressions, and assessed by colony counting. Both disinfectants tested were shown to be effective in reducing the microbial presence on the impression materials, achieving at least a 102 reduction of microbial counts compared to water rinsing. However, Sterigum was generally less effective on the Elite elastomer and could not grant disinfection on six-hour aged P. aeruginosa and C. albicans microbial layers. The results of this study suggest that the materials used for the impressions influence the efficacy of disinfection. Disinfectants should be tested according to conditions encountered in everyday clinical practice and the need for immediate disinfection of impressions should be clearly indicated by manufacturers.

  12. Tapping mode microwave impedance microscopy

    KAUST Repository

    Lai, K.

    2009-01-01

    We report tapping mode microwave impedance imaging based on atomic force microscope platforms. The shielded cantilever probe is critical to localize the tip-sample interaction near the tip apex. The modulated tip-sample impedance can be accurately simulated by the finite-element analysis and the result agrees quantitatively to the experimental data on a series of thin-film dielectric samples. The tapping mode microwave imaging is also superior to the contact mode in that the thermal drift in a long time scale is totally eliminated and an absolute measurement on the dielectric properties is possible. We demonstrated tapping images on working nanodevices, and the data are consistent with the transport results. © 2009 American Institute of Physics.

  13. Radioactive substances in tap water.

    Science.gov (United States)

    Atsuumi, Ryo; Endo, Yoshihiko; Suzuki, Akihiko; Kannotou, Yasumitu; Nakada, Masahiro; Yabuuchi, Reiko

    2014-01-01

    A 9.0 magnitude (M) earthquake with an epicenter off the Sanriku coast occurred at 14: 46 on March 11, 2011. TEPCO Fukushima Daiichi Nuclear Power Plant (F-1 NPP) was struck by the earthquake and its resulting tsunami. Consequently a critical nuclear disaster developed, as a large quantity of radioactive materials was released due to a hydrogen blast. On March 16(th), 2011, radioiodine and radioactive cesium were detected at levels of 177 Bq/kg and 58 Bq/kg, respectively, in tap water in Fukushima city (about 62km northwest of TEPCO F-1 NPP). On March 20th, radioiodine was detected in tap water at a level of 965 Bq/kg, which is over the value-index of restrictions on food and drink intake (radioiodine 300 Bq/kg (infant intake 100 Bq/kg)) designated by the Nuclear Safety Commission. Therefore, intake restriction measures were taken regarding drinking water. After that, although the all intake restrictions were lifted, in order to confirm the safety of tap water, an inspection system was established to monitor all tap water in the prefecture. This system has confirmed that there has been no detection of radioiodine or radioactive cesium in tap water in the prefecture since May 5(th), 2011. Furthermore, radioactive strontium ((89) Sr, (90)Sr) and plutonium ((238)Pu, (239)Pu+(240)Pu) in tap water and the raw water supply were measured. As a result, (89) Sr, (238)Pu, (239)Pu+(240)Pu were undetectable and although (90)Sr was detected, its committed effective dose of 0.00017 mSv was much lower than the yearly 0.1 mSv of the World Health Organization guidelines for drinking water quality. In addition, the results did not show any deviations from past inspection results.

  14. Direct-scanning alpha spectrometer for americium and plutonium contamination on highly-enriched uranium surfaces

    International Nuclear Information System (INIS)

    Ward, W.C.; Martinez, H.E.; Abeyta, C.L.; Morgan, A.N.; Nelson, T.O.

    1997-01-01

    Trace Pu 239 and Am 241 contamination on a surface whose alpha count is dominated by U 235 and U 234 decay has been successfully quantified by counting swipes in external alpha spectroscopy chambers. The swipe process, however, is labor intensive and subject to uncertainties in the swiping process as well as degraded spectral resolution due to the presence of the swipe material. A multichannel instrument for automated in situ measurements of interior and exterior contamination has been developed which incorporates a rotary table, 13 fixed ion-implanted silicon detectors, and spectroscopy electronics. Custom software was written to allow alpha spectrometer to function as a virtual instrument in the LabView environment. This system gives improved speed and resolution as well as a complete log of the location of areas of high surface contamination, a feature not practical to obtain by other methods, and one which opens the possibility of long term studies such as Pu outgrowth evaluation employing the instrument. The authors present performance data as well as system integration, calibration, control, and dynamic geometric efficiency calculations related to the design of this and next generation systems

  15. Morphology and Differentiation of MG63 Osteoblast Cells on Saliva Contaminated Implant Surfaces

    Directory of Open Access Journals (Sweden)

    Neda Shams

    2015-11-01

    Full Text Available Objectives: Osteoblasts are the most important cells in the osseointegration process. Despite years of study on dental Implants, limited studies have discussed the effect of saliva on the adhesion process of osteoblasts to implant surfaces. The aim of this in vitro study was to evaluate the effect of saliva on morphology and differentiation of osteoblasts attached to implant surfaces.Materials and Methods: Twelve Axiom dental implants were divided into two groups. Implants of the case group were placed in containers, containing saliva, for 40 minutes. Then, all the implants were separately stored in a medium containing MG63 human osteoblasts for a week. Cell morphology and differentiation were assessed using a scanning electron microscope and their alkaline phosphatase (ALP activity was determined. The t-test was used to compare the two groups.Results: Scanning electron microscopic observation of osteoblasts revealed round or square cells with fewer and shorter cellular processes in saliva contaminated samples, whereas elongated, fusiform and well-defined cell processes were seen in the control group. ALP level was significantly lower in case compared to control group (P<0.05.Conclusion: Saliva contamination alters osteoblast morphology and differentiation and may subsequently interfere with successful osseointegration. Thus, saliva contamination of bone and implant must be prevented or minimized.

  16. Removal of contaminated concrete surfaces by microwave heating: Phase 1 results

    International Nuclear Information System (INIS)

    White, T.L.; Grubb, R.G.; Pugh, L.P.; Foster, D. Jr.; Box, W.D.

    1992-01-01

    Oak Ridge National Laboratory (ORNL) is developing a microwave heating process to remove radiologically contaminated surface layers from concrete. The microwave energy is directed at the concrete surface and heats the concrete and free water present in the concrete matrix. Continued heating produces steam-pressure-induced mechanical stresses that cause the concrete surface to burst. The concrete particles from this steam explosion are small enough to be removed by a vacuum system, yet less than 1% of the debris is small enough to pose an airborne contamination hazard. The first phase of this program has demonstrated reliable removal of noncontaminated concrete surfaces at frequencies of 2.45 GHz and 10.6 GHz. Continuous concrete removal rates of 1.07 cm 3 /s with 5.2 kW of 2.45.-GHz power and 2.11 cm 3 /s with 3.6 kW of 10.6-GHz power have been demonstrated. Figures-of-merit for microwave removal of concrete have been calculated to be 0.21 cm 3 /s/kW at 2.45 GHz and 0.59 cm 3 /s/kW at 10.6 GHz. The amount of concrete removed in a single pass can be controlled by choosing the frequency and power of the microwave system

  17. Suitability of artificial sweeteners as indicators of raw wastewater contamination in surface water and groundwater.

    Science.gov (United States)

    Tran, Ngoc Han; Hu, Jiangyong; Li, Jinhua; Ong, Say Leong

    2014-01-01

    There is no quantitative data on the occurrence of artificial sweeteners in the aquatic environment in Southeast Asian countries, particularly no information on their suitability as indicators of raw wastewater contamination on surface water and groundwater. This study provided the first quantitative information on the occurrence of artificial sweeteners in raw wastewater, surface water and groundwater in the urban catchment area in Singapore. Acesulfame, cyclamate, saccharin, and sucralose were ubiquitous in raw wastewater samples at concentrations in the range of ng/L-μg/L, while other sweeteners were not found or found only in a few of the raw wastewater samples. Residential and commercial effluents were demonstrated to be the two main sources of artificial sweeteners entering the municipal sewer systems. Relatively higher concentrations of the detected sweeteners were frequently found in surface waters at the sampling sites located in the residential/commercial areas. No significant difference in the concentrations of the detected sweeteners in surface water or groundwater was noted between wet and dry weather conditions (unpaired T-test, p> 0.05). Relatively higher concentrations and detection frequencies of acesulfame, cyclamate and saccharin in surface water samples were observed at the potentially impacted sampling sites, while these sweeteners were absent in most of the background surface water samples. Similarly, acesulfame, cyclamate, and saccharin were found in most groundwater samples at the monitoring well (GW6), which is located close to known leaking sewer segment; whereas these were absent in the background monitoring well, which is located in the catchment with no known wastewater sources. Taken together, the results suggest that acesulfame, cyclamate, and saccharin can be used as potential indicators of raw wastewater contamination in surface water and groundwater. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Innovative technology for expedited site remediation of extensive surface and subsurface contamination

    International Nuclear Information System (INIS)

    Audibert, J.M.E.; Lew, L.R.

    1994-01-01

    Large scale surface and subsurface contamination resulted from numerous releases of feed stock, process streams, waste streams, and final product at a major chemical plant. Soil and groundwater was contaminated by numerous compounds including lead, tetraethyl lead, ethylene dibromide, ethylene dichloride, and toluene. The state administrative order dictated that the site be investigated fully, that remedial alternative be evaluated, and that the site be remediated within a year period. Because of the acute toxicity and extreme volatility of tetraethyl lead and other organic compounds present at the site and the short time frame ordered by the regulators, innovative approaches were needed to carry out the remediation while protecting plant workers, remediation workers, and the public

  19. Evaluation of wastewater contaminant transport in surface waters using verified Lagrangian sampling

    Science.gov (United States)

    Antweiler, Ronald C.; Writer, Jeffrey H.; Murphy, Sheila F.

    2014-01-01

    Contaminants released from wastewater treatment plants can persist in surface waters for substantial distances. Much research has gone into evaluating the fate and transport of these contaminants, but this work has often assumed constant flow from wastewater treatment plants. However, effluent discharge commonly varies widely over a 24-hour period, and this variation controls contaminant loading and can profoundly influence interpretations of environmental data. We show that methodologies relying on the normalization of downstream data to conservative elements can give spurious results, and should not be used unless it can be verified that the same parcel of water was sampled. Lagrangian sampling, which in theory samples the same water parcel as it moves downstream (the Lagrangian parcel), links hydrologic and chemical transformation processes so that the in-stream fate of wastewater contaminants can be quantitatively evaluated. However, precise Lagrangian sampling is difficult, and small deviations – such as missing the Lagrangian parcel by less than 1 h – can cause large differences in measured concentrations of all dissolved compounds at downstream sites, leading to erroneous conclusions regarding in-stream processes controlling the fate and transport of wastewater contaminants. Therefore, we have developed a method termed “verified Lagrangian” sampling, which can be used to determine if the Lagrangian parcel was actually sampled, and if it was not, a means for correcting the data to reflect the concentrations which would have been obtained had the Lagrangian parcel been sampled. To apply the method, it is necessary to have concentration data for a number of conservative constituents from the upstream, effluent, and downstream sites, along with upstream and effluent concentrations that are constant over the short-term (typically 2–4 h). These corrections can subsequently be applied to all data, including non-conservative constituents. Finally, we

  20. Evaluation of wastewater contaminant transport in surface waters using verified Lagrangian sampling.

    Science.gov (United States)

    Antweiler, Ronald C; Writer, Jeffrey H; Murphy, Sheila F

    2014-02-01

    Contaminants released from wastewater treatment plants can persist in surface waters for substantial distances. Much research has gone into evaluating the fate and transport of these contaminants, but this work has often assumed constant flow from wastewater treatment plants. However, effluent discharge commonly varies widely over a 24-hour period, and this variation controls contaminant loading and can profoundly influence interpretations of environmental data. We show that methodologies relying on the normalization of downstream data to conservative elements can give spurious results, and should not be used unless it can be verified that the same parcel of water was sampled. Lagrangian sampling, which in theory samples the same water parcel as it moves downstream (the Lagrangian parcel), links hydrologic and chemical transformation processes so that the in-stream fate of wastewater contaminants can be quantitatively evaluated. However, precise Lagrangian sampling is difficult, and small deviations - such as missing the Lagrangian parcel by less than 1h - can cause large differences in measured concentrations of all dissolved compounds at downstream sites, leading to erroneous conclusions regarding in-stream processes controlling the fate and transport of wastewater contaminants. Therefore, we have developed a method termed "verified Lagrangian" sampling, which can be used to determine if the Lagrangian parcel was actually sampled, and if it was not, a means for correcting the data to reflect the concentrations which would have been obtained had the Lagrangian parcel been sampled. To apply the method, it is necessary to have concentration data for a number of conservative constituents from the upstream, effluent, and downstream sites, along with upstream and effluent concentrations that are constant over the short-term (typically 2-4h). These corrections can subsequently be applied to all data, including non-conservative constituents. Finally, we show how data

  1. Advanced LWIR hyperspectral sensor for on-the-move proximal detection of liquid/solid contaminants on surfaces

    Science.gov (United States)

    Giblin, Jay P.; Dixon, John; Dupuis, Julia R.; Cosofret, Bogdan R.; Marinelli, William J.

    2017-05-01

    Sensor technologies capable of detecting low vapor pressure liquid surface contaminants, as well as solids, in a noncontact fashion while on-the-move continues to be an important need for the U.S. Army. In this paper, we discuss the development of a long-wave infrared (LWIR, 8-10.5 μm) spatial heterodyne spectrometer coupled with an LWIR illuminator and an automated detection algorithm for detection of surface contaminants from a moving vehicle. The system is designed to detect surface contaminants by repetitively collecting LWIR reflectance spectra of the ground. Detection and identification of surface contaminants is based on spectral correlation of the measured LWIR ground reflectance spectra with high fidelity library spectra and the system's cumulative binary detection response from the sampled ground. We present the concepts of the detection algorithm through a discussion of the system signal model. In addition, we present reflectance spectra of surfaces contaminated with a liquid CWA simulant, triethyl phosphate (TEP), and a solid simulant, acetaminophen acquired while the sensor was stationary and on-the-move. Surfaces included CARC painted steel, asphalt, concrete, and sand. The data collected was analyzed to determine the probability of detecting 800 μm diameter contaminant particles at a 0.5 g/m2 areal density with the SHSCAD traversing a surface.

  2. Surface tailored organobentonite enhances bacterial proliferation and phenanthrene biodegradation under cadmium co-contamination

    International Nuclear Information System (INIS)

    Mandal, Asit; Biswas, Bhabananda; Sarkar, Binoy; Patra, Ashok K.; Naidu, Ravi

    2016-01-01

    Co-contamination of soil and water with polycyclic aromatic hydrocarbon (PAH) and heavy metals makes biodegradation of the former extremely challenging. Modified clay-modulated microbial degradation provides a novel insight in addressing this issue. This study was conducted to evaluate the growth and phenanthrene degradation performance of Mycobacterium gilvum VF1 in the presence of a palmitic acid (PA)-grafted Arquad® 2HT-75-based organobentonite in cadmium (Cd)-phenanthrene co-contaminated water. The PA-grafted organobentonite (ABP) adsorbed a slightly greater quantity of Cd than bentonite at up to 30 mg L"−"1 metal concentration, but its highly negative surface charge imparted by carboxylic groups indicated the potential of being a significantly superior adsorbent of Cd at higher metal concentrations. In systems co-contained with Cd (5 and 10 mg L"−"1), the Arquad® 2HT-75-modified bentonite (AB) and PA-grafted organobentonite (ABP) resulted in a significantly higher (72–78%) degradation of phenanthrene than bentonite (62%) by the bacterium. The growth and proliferation of bacteria were supported by ABP which not only eliminated Cd toxicity through adsorption but also created a congenial microenvironment for bacterial survival. The macromolecules produced during ABP–bacteria interaction could form a stable clay-bacterial cluster by overcoming the electrostatic repulsion among individual components. Findings of this study provide new insights for designing clay modulated PAH bioremediation technologies in mixed-contaminated water and soil. - Highlights: • Surface tailored organobentonite synthesised and characterised • Modified clay adsorbs Cd and reduces toxicity to Mycobacterium gilvum. • It creates congenial microenvironment for bacterial survival. • It enhances phenanthrene biodegradation in metal co-contaminated condition.

  3. Surface tailored organobentonite enhances bacterial proliferation and phenanthrene biodegradation under cadmium co-contamination

    Energy Technology Data Exchange (ETDEWEB)

    Mandal, Asit [Future Industries Institute (formerly Centre for Environmental Risk Assessment and Remediation), University of South Australia, Mawson Lakes, SA 5095 (Australia); Indian Council of Agricultural Research (ICAR), Indian Institute of Soil Science, Bhopal (India); Biswas, Bhabananda [Future Industries Institute (formerly Centre for Environmental Risk Assessment and Remediation), University of South Australia, Mawson Lakes, SA 5095 (Australia); Cooperative Research Centre for Contamination Assessment and Remediation of the Environment (CRC CARE), ACT Building, University of Newcastle, Callaghan, NSW 2308 (Australia); Sarkar, Binoy, E-mail: binoy.sarkar@unisa.edu.au [Future Industries Institute (formerly Centre for Environmental Risk Assessment and Remediation), University of South Australia, Mawson Lakes, SA 5095 (Australia); Cooperative Research Centre for Contamination Assessment and Remediation of the Environment (CRC CARE), ACT Building, University of Newcastle, Callaghan, NSW 2308 (Australia); Patra, Ashok K. [Indian Council of Agricultural Research (ICAR), Indian Institute of Soil Science, Bhopal (India); Naidu, Ravi, E-mail: ravi.naidu@newcastle.edu.au [Cooperative Research Centre for Contamination Assessment and Remediation of the Environment (CRC CARE), ACT Building, University of Newcastle, Callaghan, NSW 2308 (Australia); Global Centre for Environmental Remediation (GCER), Faculty of Science and Information Technology, University of Newcastle, Callaghan, NSW 2308 (Australia)

    2016-04-15

    Co-contamination of soil and water with polycyclic aromatic hydrocarbon (PAH) and heavy metals makes biodegradation of the former extremely challenging. Modified clay-modulated microbial degradation provides a novel insight in addressing this issue. This study was conducted to evaluate the growth and phenanthrene degradation performance of Mycobacterium gilvum VF1 in the presence of a palmitic acid (PA)-grafted Arquad® 2HT-75-based organobentonite in cadmium (Cd)-phenanthrene co-contaminated water. The PA-grafted organobentonite (ABP) adsorbed a slightly greater quantity of Cd than bentonite at up to 30 mg L{sup −1} metal concentration, but its highly negative surface charge imparted by carboxylic groups indicated the potential of being a significantly superior adsorbent of Cd at higher metal concentrations. In systems co-contained with Cd (5 and 10 mg L{sup −1}), the Arquad® 2HT-75-modified bentonite (AB) and PA-grafted organobentonite (ABP) resulted in a significantly higher (72–78%) degradation of phenanthrene than bentonite (62%) by the bacterium. The growth and proliferation of bacteria were supported by ABP which not only eliminated Cd toxicity through adsorption but also created a congenial microenvironment for bacterial survival. The macromolecules produced during ABP–bacteria interaction could form a stable clay-bacterial cluster by overcoming the electrostatic repulsion among individual components. Findings of this study provide new insights for designing clay modulated PAH bioremediation technologies in mixed-contaminated water and soil. - Highlights: • Surface tailored organobentonite synthesised and characterised • Modified clay adsorbs Cd and reduces toxicity to Mycobacterium gilvum. • It creates congenial microenvironment for bacterial survival. • It enhances phenanthrene biodegradation in metal co-contaminated condition.

  4. Visible-light system for detecting doxorubicin contamination on skin and surfaces.

    Science.gov (United States)

    Van Raalte, J; Rice, C; Moss, C E

    1990-05-01

    A portable system that uses fluorescence stimulated by visible light to identify doxorubicin contamination on skin and surfaces was studied. When activated by violet-blue light in the 465-nm range, doxorubicin fluoresces, emitting orange-red light in the 580-nm range. The light source to stimulate fluorescence was a slide projector with a filter to selectively pass short-wave (blue) visible light. Fluorescence was both observed visually with viewing spectacles and photographed. Solutions of doxorubicin in sterile 0.9% sodium chloride injection were prepared in nine standard concentrations ranging from 2 to 0.001 mg/mL. Droplets of each admixture were placed on stainless steel, laboratory coat cloth, pieces of latex examination glove, bench-top absorbent padding, and other materials on which antineoplastics might spill or leak. These materials then were stored for up to eight weeks and photographed weekly. The relative ability of water, household bleach, hydrogen peroxide solution, and soap solution to deactivate doxorubicin was also measured. Finally, this system was used to inspect the antineoplastic-drug preparation and administration areas of three outpatient cancer clinics for doxorubicin contamination. Doxorubicin fluorescence was easily detectable with viewing spectacles when a slide projector was used as the light source. The photographic method was sensitive for doxorubicin concentrations from 2.0 to 0.001 mg/mL. Immersion of study materials in bleach for one minute eliminated detectable fluorescence. Doxorubicin contamination is detectable for at least eight weeks in the ambient environment. Probable doxorubicin contamination was detected in two of the three clinics surveyed. A safe, portable system that uses fluorescence stimulated by visible light is a sensitive method for detecting doxorubicin on skin and surfaces.

  5. Clostridium difficile from food and surface samples in a Belgian nursing home: an unlikely source of contamination.

    Science.gov (United States)

    Rodriguez, C; Korsak, N; Taminiau, B; Avesani, V; Van Broeck, J; Brach, P; Delmée, M; Daube, G

    2015-04-01

    This study investigates the contamination of foods and surfaces with Clostridium difficile in a single nursing home. C. difficile PCR-ribotype 078 was found in one food sample and in none of the tested surfaces. These results indicate that food and surfaces are an unlikely source of C. difficile infection in this setting. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Verification of surface contamination density standard using clearance automatic laser inspection system for objects from a nuclear power plant

    International Nuclear Information System (INIS)

    Sasaki, Michiya; Ogino, Haruyuki; Ichiji, Takeshi; Hattori, Takatoshi

    2008-01-01

    In the clearance level inspection in Japan, it is necessary to indicate that the activity level of the target object must be less than not only the clearance levels, but also the surface contamination density standards. The classification measurements for these two standards have been performed separately, and the GM survey meters based on beta-ray measurement have mainly been used for surface contamination density measurement so far. Recently the Clearance Automatic Laser Inspection System, named CLALIS, has been developed to estimate the low-level activity concentration. This system consists of 3-dimensional laser scanner for shape measurement and eight large NE102A plastic scintillation detectors for gamma-ray measurement, and it has been clarified that the CLALIS has adequate detection ability for clearance measurement of both metal scraps and concrete debris. In this study, we compared the surface contamination densities for a number of actual contaminated and non-contaminated objects generated inside from the radiation controlled area at the Kashiwazaki-Kariwa nuclear power station by using the CLALIS and the GM survey meter. As a result, since CLALIS could detect the surface contamination as well as the GM survey meter for all measurement targets, it was revealed that CLALIS can rationally achieve clearance level inspection in a single radiation measurement. The practicality of CLALIS in view of the detection limit and processing time was discussed by comparison with the usual radiation monitors for surface contamination measurement. (author)

  7. Integrated modelling for assessing the risk of groundwater contaminants to human health and surface water ecosystems

    DEFF Research Database (Denmark)

    McKnight, Ursula S.; Rasmussen, Jes; Funder, Simon G.

    2010-01-01

    for evaluating the impact of a TCE groundwater plume, located in an area with protected drinking water interests, to human health and surface water ecosystems. This is accomplished by coupling the system dynamicsbased decision support system CARO-Plus to the aquatic ecosystem model AQUATOX via an analytical......The practical implementation of the European Water Framework Directive has resulted in an increased focus on the groundwater-surface water interaction zone. A gap exists with respect to preliminary assessment methodologies that are capable of evaluating and prioritising point sources...... volatilisation model for the stream. The model is tested on a Danish case study involving a 750 m long TCE groundwater plume discharging into a stream. The initial modelling results indicate that TCE contaminant plumes with μgL-1 concentrations entering surface water systems do not pose a significant risk...

  8. Contamination by urban superficial runoff: accumulated heavy metals on a road surface

    Directory of Open Access Journals (Sweden)

    Carlos Alfonso Zafra Mejía

    2007-01-01

    Full Text Available Studying the behaviour of accumulated contamination on urban surfaces is important in designing control methods minimising the impacts of surface runoff on the environment. This paper presents data regarding the sediment collected on the surface of an urban road in the city of Torrelavega in northern Spain during a period of 65 days during which 132 samples were collected. Two types of sediment collection samples were obtained: vacuumed dry samples (free load and those swept up following vacuuming (fixed load. The results showed that heavy metal concentration in the collected sediment (Pb, Zn, Cu and Cd was inversely proportional to particle diameter. High heavy metal concentrations were found in the smaller fraction (63 pm. Regression equations were calculated for heavy metal concentration regarding particle diameter. Large heavy metal loads were found in the larger fraction (125 pm. The results provide information for analysing runoff water quality in urban areas and designing treatment strategies.

  9. Effectiveness of disinfection with alcohol 70% (w/v of contaminated surfaces not previously cleaned

    Directory of Open Access Journals (Sweden)

    Maurício Uchikawa Graziano

    2013-04-01

    Full Text Available OBJECTIVE: To evaluate the disinfectant effectiveness of alcohol 70% (w/v using friction, without previous cleaning, on work surfaces, as a concurrent disinfecting procedure in Health Services. METHOD: An experimental, randomized and single-blinded laboratory study was undertaken. The samples were enamelled surfaces, intentionally contaminated with Serratia marcescens microorganisms ATCC 14756 106 CFU/mL with 10% of human saliva added, and were submitted to the procedure of disinfection WITHOUT previous cleaning. The results were compared to disinfection preceded by cleaning. RESULTS: There was a reduction of six logarithms of the initial microbial population, equal in the groups WITH and WITHOUT previous cleaning (p=0.440 and a residual microbial load ≤ 102 CFU. CONCLUSION: The research demonstrated the acceptability of the practice evaluated, bringing an important response to the area of health, in particular to Nursing, which most undertakes procedures of concurrent cleaning /disinfecting of these work surfaces.

  10. Effectiveness of disinfection with alcohol 70% (w/v of contaminated surfaces not previously cleaned

    Directory of Open Access Journals (Sweden)

    Maurício Uchikawa Graziano

    Full Text Available OBJECTIVE: To evaluate the disinfectant effectiveness of alcohol 70% (w/v using friction, without previous cleaning, on work surfaces, as a concurrent disinfecting procedure in Health Services. METHOD: An experimental, randomized and single-blinded laboratory study was undertaken. The samples were enamelled surfaces, intentionally contaminated with Serratia marcescens microorganisms ATCC 14756 106 CFU/mL with 10% of human saliva added, and were submitted to the procedure of disinfection WITHOUT previous cleaning. The results were compared to disinfection preceded by cleaning. RESULTS: There was a reduction of six logarithms of the initial microbial population, equal in the groups WITH and WITHOUT previous cleaning (p=0.440 and a residual microbial load ≤ 102 CFU. CONCLUSION: The research demonstrated the acceptability of the practice evaluated, bringing an important response to the area of health, in particular to Nursing, which most undertakes procedures of concurrent cleaning /disinfecting of these work surfaces.

  11. Optical Interferometry with Flexible Coherent Fiber Bundle for Measuring Deposits or Contamination on Surfaces and Inside Tubes

    Data.gov (United States)

    National Aeronautics and Space Administration — A new measuring/cleaning method for closed surfaces (pipes) applicable to removing contaminants (oil films, fungus, rust) from NASA instruments and spacecraft is...

  12. Analysis of body surface radiological contamination for inbound people from Japan to China during the Fukushima nuclear accident

    International Nuclear Information System (INIS)

    Yuan Long; Ma Weidong; Lei Cuiping; Chen Huifang; Li Yuwen; Liu Ying

    2012-01-01

    Objective: To investigate the radiological contamination of body surface for inbound people from Japan to China during Fukushima nuclear accident. Methods: According to The guidance for radiological contamination management for body surface issued by Chinese Center for Disease Control and Prevention, for people evacuated from Japan, the body surface monitoring of radiological contamination was performed by the related agencies in main provinces and cities in China. The monitoring data were collected, analyzed and reported to Ministry of Health. Results: A total of 432 persons were checked. The monitoring results of 429 cases were close to the background level, while those of three persons were higher than the background level. Conclusions: In general,the detected results were as low as the background level. The radiological contamination monitoring of body surface for people from Japan could provide scientific data to relax the horror and panic among them. (authors)

  13. An Immunoassay for Quantification of Contamination by Raw Meat Juice on Food Contact Surfaces.

    Science.gov (United States)

    Chen, Fur-Chi; Godwin, Sandria; Chambers, Edgar

    2016-11-01

    Raw chicken products often are contaminated with Salmonella and Campylobacter , which can be transmitted from packages to contact surfaces. Raw meat juices from these packages also provide potential media for cross-contamination. There are limited quantitative data on the levels of consumer exposure to raw meat juice during shopping for and handling of chicken products. An exposure assessment is needed to quantify the levels of transmission and to assess the risk. An enzyme-linked immunosorbent assay (ELISA) was developed and validated for quantitative detection of raw meat juice on hands and various food contact surfaces. Analytical procedures were designed to maximize the recovery of raw meat juice from various surfaces: hands, plastic, wood, stainless steel, laminated countertops, glass, and ceramics. The ELISA was based on the detection of a soluble muscle protein, troponin I (TnI), in the raw meat juice. The assay can detect levels as low as 1.25 ng of TnI, which is equivalent to less than 1 μl of the raw meat juice. The concentrations of TnI in the raw meat juices from 10 retail chicken packages, as determined by ELISA, were between 0.46 and 3.56 ng/μl, with an average of 1.69 ng/μl. The analytical procedures, which include swabbing, extraction, and concentration, enable the detection of TnI from various surfaces. The recoveries of raw meat juice from surfaces of hands were 92%, and recoveries from other tested surfaces were from 55% on plastic cutting boards to 75% on laminated countertops. The ELISA developed has been used for monitoring the transfer of raw meat juice during shopping for and handling of raw chicken products in our studies. The assay also can be applied to other raw meat products, such as pork and beef.

  14. Geothermal Energy: Tapping the Potential

    Science.gov (United States)

    Johnson, Bill

    2008-01-01

    Ground source geothermal energy enables one to tap into the earth's stored renewable energy for heating and cooling facilities. Proper application of ground-source geothermal technology can have a dramatic impact on the efficiency and financial performance of building energy utilization (30%+). At the same time, using this alternative energy…

  15. Tapping into Industry and Academia

    DEFF Research Database (Denmark)

    Markus, Arjan; Rosenkopf, Lori

    This paper studies how different boundary-spanning mechanisms concurrently impact firm innovation. We specifically examine how inbound mobility and R&D collaboration interact when firms use these mechanisms to tap into two distinct knowledge domains: industry and academia. To examine the impacts...

  16. Introducing the TAPS Pyramid Model

    Science.gov (United States)

    Earle, Sarah

    2015-01-01

    The Teacher Assessment in Primary Science (TAPS) project is a three-year project based at Bath Spa University and funded by the Primary Science Teaching Trust (PSTT). It aims to develop support for a valid, reliable and manageable system of science assessment that will have a positive impact on children's learning. In this article, the author…

  17. Comparative evaluations of surface contamination detectors calibration with radioactive sources - used in the Goiania accident, and standard sources

    International Nuclear Information System (INIS)

    Becker, P.H.B.; Marecha, M.H.H.

    1997-01-01

    The construction of Cs-137 standard flat sources for calibration of surface contamination detectors, used in the Goiania accident in 1987, is described and the procedures adopted are reported. At that time, standard sources were not available. Nowadays the Instituto de Radioprotecao e Dosimetria has standard sources acquired from Amersham which are used as calibration standards for surface contamination detectors. Comparative evaluations between the standard flat sources constructed for the accident and the calibrated ones are presented

  18. Position-sensitive radiation monitoring (surface contamination monitor). Innovative technology summary report

    International Nuclear Information System (INIS)

    1999-06-01

    The Shonka Research Associates, Inc. Position-Sensitive Radiation Monitor both detects surface radiation and prepares electronic survey map/survey report of surveyed area automatically. The electronically recorded map can be downloaded to a personal computer for review and a map/report can be generated for inclusion in work packages. Switching from beta-gamma detection to alpha detection is relatively simple and entails moving a switch position to alpha and adjusting the voltage level to an alpha detection level. No field calibration is required when switching from beta-gamma to alpha detection. The system can be used for free-release surveys because it meets the federal detection level sensitivity limits requires for surface survey instrumentation. This technology is superior to traditionally-used floor contamination monitor (FCM) and hand-held survey instrumentation because it can precisely register locations of radioactivity and accurately correlate contamination levels to specific locations. Additionally, it can collect and store continuous radiological data in database format, which can be used to produce real-time imagery as well as automated graphics of survey data. Its flexible design can accommodate a variety of detectors. The cost of the innovative technology is 13% to 57% lower than traditional methods. This technology is suited for radiological surveys of flat surfaces at US Department of Energy (DOE) nuclear facility decontamination and decommissioning (D and D) sites or similar public or commercial sites

  19. Purification of fuel and nitrate contaminated ground water using a free water surface constructed wetland plant

    Energy Technology Data Exchange (ETDEWEB)

    Machate, T.; Heuermann, E.; Schramm, K.W.; Kettrup, A.

    1999-10-01

    Contaminated ground water from a former coke plant site was purified in a free water surface (FWS) constructed wetland plant during a 3-mo short-term experiment. The pilot plant (total surface area 27 m{sup 2}) was filled with a 1 m thick lava-gravel substrate planted with cattail (Typha spp.) and bulrush (Scirpus lacustrls). Major contaminants were low to moderate concentrations of polycyclic aromatic hydrocarbons, BTEX, nitrate, and nitrite. The wetland was dosed at hydraulic loading rates of q{sub A} = 4.8 and 9.6 cm d{sup {minus}1} with a hydraulic residence time (HRT) of 13.7 and 6.8 d. The surface removal rates of PAH were between 98.8 and 1914 mg m{sup {minus}2} d{sup {minus}1}. Efficiency was always {gt}99%. Extraction of lava gravel showed that approx. 0.4% of the applied PAH were retained on the substratum. The ratio of {Sigma}2,3-ring PAH and {Sigma}4,5,6-ring PAH showed a shift from 1:0.11 in water to 1:2.5 in lava. The removal of BTEX was {gt}99%, but might be in part due to volatilization. The efficiency in the removal of nitrate was 91% and of nitrite was 97%. Purification performance was not influenced by hydraulic loading rates or after die-back of the macrophytes.

  20. Removal of carbon contaminations by RF plasma generated reactive species and subsequent effects on optical surface

    Energy Technology Data Exchange (ETDEWEB)

    Yadav, P. K., E-mail: praveenyadav@rrcat.gov.in; Rai, S. K.; Modi, M. H.; Nayak, M.; Lodha, G. S. [Indus Synchrotron Utilization Division, Raja Ramanna Centre for Advanced Technology, Indore-452013 (India); Kumar, M.; Chakera, J. A.; Naik, P. A. [Laser Plasma Laboratory, Laser Plasma Division, Raja Ramanna Centre for Advanced Technology, Indore-452013 (India)

    2015-06-24

    Carbon contamination on optical elements is a serious issue in synchrotron beam lines for several decades. The basic mechanism of carbon deposition on optics and cleaning strategies are not fully understood. Carbon growth mechanism and optimized cleaning procedures are worldwide under development stage. Optimized RF plasma cleaning is considered an active remedy for the same. In present study carbon contaminated optical test surfaces (carbon capped tungsten thin film) are exposed for 30 minutes to four different gases, rf plasma at constant power and constant dynamic pressure. Structural characterization (thickness, roughness and density) of virgin samples and plasma exposed samples was done by soft x-ray (λ=80 Å) reflectivity measurements at Indus-1 reflectivity beam line. Different gas plasma removes carbon with different rate (0.4 to 0.65 nm /min). A thin layer 2 to 9 nm of different roughness and density is observed at the top surface of tungsten film. Ar gas plasma is found more suitable for cleaning of tungsten surface.

  1. Position-sensitive radiation monitoring (surface contamination monitor). Innovative technology summary report

    Energy Technology Data Exchange (ETDEWEB)

    1999-06-01

    The Shonka Research Associates, Inc. Position-Sensitive Radiation Monitor both detects surface radiation and prepares electronic survey map/survey report of surveyed area automatically. The electronically recorded map can be downloaded to a personal computer for review and a map/report can be generated for inclusion in work packages. Switching from beta-gamma detection to alpha detection is relatively simple and entails moving a switch position to alpha and adjusting the voltage level to an alpha detection level. No field calibration is required when switching from beta-gamma to alpha detection. The system can be used for free-release surveys because it meets the federal detection level sensitivity limits requires for surface survey instrumentation. This technology is superior to traditionally-used floor contamination monitor (FCM) and hand-held survey instrumentation because it can precisely register locations of radioactivity and accurately correlate contamination levels to specific locations. Additionally, it can collect and store continuous radiological data in database format, which can be used to produce real-time imagery as well as automated graphics of survey data. Its flexible design can accommodate a variety of detectors. The cost of the innovative technology is 13% to 57% lower than traditional methods. This technology is suited for radiological surveys of flat surfaces at US Department of Energy (DOE) nuclear facility decontamination and decommissioning (D and D) sites or similar public or commercial sites.

  2. Laser assisted decontamination of metal surface: Evidence of increased surface absorptivity due to field enhancement caused by transparent/semi-transparent contaminant particulates

    International Nuclear Information System (INIS)

    Nilaya, J. Padma; Biswas, Dhruba J.

    2010-01-01

    Small signal absorption measurements of the incident coherent radiation by the metal surface have revealed an increase in the absorption by the surface in presence of transparent/semi-transparent particulates on it. This effect, identified as field enhanced surface absorption, has been found to increase with reduction in the average particulate size. Consequently higher laser assisted removal efficiency of contamination from a metal surface has been observed for smaller contaminant particulates. These measurements have been carried out utilizing coherent radiations of two different wavelengths so chosen that for one the particulates are totally transparent while for the other they are partially transparent.

  3. Application of autonomous robotics to surveillance of waste storage containers for radioactive surface contamination

    International Nuclear Information System (INIS)

    Sweeney, F.J.; Beckerman, M.; Butler, P.L.; Jones, J.P.; Reister, D.B.

    1991-01-01

    This paper describes a proof-of-principal demonstration performed with the HERMIES-III mobile robot to automate the inspection of waste storage drums for radioactive surface contamination and thereby reduce the human burden of operating a robot and worker exposure to potentially hazardous environments. Software and hardware for the demonstration were developed by a team consisting of Oak Ridge National Laboratory, and the Universities of Florida, Michigan, Tennessee, and Texas. Robot navigation, machine vision, manipulator control, parallel processing and human-machine interface techniques developed by the team were demonstrated utilizing advanced computer architectures. The demonstration consists of over 100,000 lines of computer code executing on nine computers

  4. Comparison of surface contamination monitors for in vivo measurement of {sup 131}I in thyroid

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, S.M.; Dantas, A.L.A.; Dantas, B.M., E-mail: salomao.marques@ymail.com [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    The routine handling of radiopharmaceuticals in nuclear medicine represents a significant risk of internal exposure to the staff. The IAEA recommends the implementation of monitoring plans for all workers subject to a risk of exposures above 1 mSv per year. However, in Brazil, such recommendation is practically unfeasible due to the lack of a sufficient number of qualified internal dosimetry services over the country. This work presents an alternative based on a simple and inexpensive methodology aimed to perform in-vivo monitoring of {sup 131}I in thyroid using portable surface contamination probes. All models evaluated showed suitable sensitivity for such application. (author)

  5. Surface Water Contamination and Los Alamos National Laboratory's Holistic Approach to Mitigation

    International Nuclear Information System (INIS)

    Katzman, D.; Veenis, S.; Reneau, S.

    2009-01-01

    A sediment and contaminant transport mitigation project is being implemented at Los Alamos National Laboratory. This effort is driven by a requirement from State of New Mexico regulators and is also in concert with efforts underway to support a surface-water diversion project by a Santa Fe, NM, public water utility. The effort is being implemented in a large geomorphically and hydrologically complex watershed. Rather than simply attempting to trap sediment in a retention basin, this effort uses a watershed-scale holistic approach with intent to promote watershed healing. (authors)

  6. Ion bombardment induced surface topography modification of clean and contaminated single crystal Cu and Si

    International Nuclear Information System (INIS)

    Lewis, G.W.; Kiriakides, G.; Carter, G.; Nobes, M.J.

    1982-01-01

    Among the several factors which lead to depth resolution deterioration during sputter profiling, surface morphological modification resulting from local differences of sputtering rate can be important. This paper reports the results of direct scanning, electron microscopic studies obtained quasi-dynamically during increasing fluence ion bombardment of the evolution of etch pit structures on Si and Cu, and how such elaboration may be suppressed. It also reports on the elaboration of contaminant-induced cone generation for different ion species bombardment. The influence of such etch pit and cone generation on achievable depth resolution is assessed. (author)

  7. Comparison of surface contamination monitors for in vivo measurement of 131I in thyroid

    International Nuclear Information System (INIS)

    Oliveira, S.M.; Dantas, A.L.A.; Dantas, B.M.

    2015-01-01

    The routine handling of radiopharmaceuticals in nuclear medicine represents a significant risk of internal exposure to the staff. The IAEA recommends the implementation of monitoring plans for all workers subject to a risk of exposures above 1 mSv per year. However, in Brazil, such recommendation is practically unfeasible due to the lack of a sufficient number of qualified internal dosimetry services over the country. This work presents an alternative based on a simple and inexpensive methodology aimed to perform in-vivo monitoring of 131 I in thyroid using portable surface contamination probes. All models evaluated showed suitable sensitivity for such application. (author)

  8. The accuracy of surface-contamination measurements; survey of UK hospitals, 1986

    International Nuclear Information System (INIS)

    Woods, M.J.

    1987-01-01

    In response to a number of concerns expressed at both national and international levels, the National Physical Laboratory (NPL) conducted a survey of UK hospitals and associated Regional Radiation Protection Services. Sources of surface contamination were distributed and participants were requested to measure these and interpret the relevant responses in terms of emission and activity per unit area. The analysis of the returns demonstrates that the vast majority of results was significantly in error and that the quality of radiation protection may be impaired. (author)

  9. Sampling for Beryllium Surface Contamination using Wet, Dry and Alcohol Wipe Sampling

    Energy Technology Data Exchange (ETDEWEB)

    Kerr, Kent [Central Missouri State Univ., Warrensburg, MO (United States)

    2004-12-01

    This research project was conducted at the National Nuclear Security Administration's Kansas City Plant, operated by Honeywell Federal Manufacturing and Technologies, in conjunction with the Safety Sciences Department of Central Missouri State University, to compare relative removal efficiencies of three wipe sampling techniques currently used at Department of Energy facilities. Efficiencies of removal of beryllium contamination from typical painted surfaces were tested by wipe sampling with dry Whatman 42 filter paper, with water-moistened (Ghost Wipe) materials, and by methanol-moistened wipes. Test plates were prepared using 100 mm X 15 mm Pyrex Petri dishes with interior surfaces spray painted with a bond coat primer. To achieve uniform deposition over the test plate surface, 10 ml aliquots of solution containing 1 beryllium and 0.1 ml of metal working fluid were transferred to the test plates and subsequently evaporated. Metal working fluid was added to simulate the slight oiliness common on surfaces in metal working shops where fugitive oil mist accumulates over time. Sixteen test plates for each wipe method (dry, water, and methanol) were processed and sampled using a modification of wiping patterns recommended by OSHA Method 125G. Laboratory and statistical analysis showed that methanol-moistened wipe sampling removed significantly more (about twice as much) beryllium/oil-film surface contamination as water-moistened wipes (p< 0.001), which removed significantly more (about twice as much) residue as dry wipes (p <0.001). Evidence for beryllium sensitization via skin exposure argues in favor of wipe sampling with wetting agents that provide enhanced residue removal efficiency.

  10. A model to determine the radiological implications of non-fixed radioactive contamination on the surfaces of packages and conveyances

    International Nuclear Information System (INIS)

    Hughes, J.S.; Warner Jones, S.M.; Lizot, M.T.; Perrin, M.L.; Thierfeld, S.; Schroedl, E.; Schwarz, G.; Rawl, R.; Munakata, M.; Hirose, M.

    2004-01-01

    The surfaces of packages and conveyances used to transport radioactive materials can sometimes become contaminated with radioactive material. This usually occurs as a result of the transfer of radioactive material from areas in which these packages and conveyances are handled. This contamination may subsequently be transferred to transport equipment, workers and to areas accessible to the public. This can represent a significant radiation safety issue that requires careful management. The current regulatory limits for non-fixed contamination on packages and conveyances have been in use for over 40 years, and are based on a simple exposure model. However, the bases on which these limits were derived have been subject to changes, as a result of successive revisions of international recommendations. In recognition of this need for a review and analysis of the current contamination limits an IAEA Co-ordinated Research Project (CRP) on the ''Radiological Aspects of Package and Conveyance Non-Fixed Contamination'' was initiated to review the scientific basis for the current regulatory limits for surface contamination. The CRP was also to develop guidance material for evaluating the radiological significance of surface contamination to workers and the public in light of state-of-the-art research, technical developments and current transport practices. The specific objectives of the work undertaken within this multi-national CRP were, in accordance with the terms of reference: To ensure that appropriate models exist for all package types including consideration of the aspects pertinent for assessing and revising a surface contamination model for transport. To collect - where possible - contamination, operational and dosimetric data to ensure modelling consistency. To use models for assessing the limitations and optimisation of radiation doses incurred in transport operations, and to consider preventive methods for package and conveyance contamination

  11. A Review of Removable Surface Contamination on Radioactive Materials Transportation Containers

    Energy Technology Data Exchange (ETDEWEB)

    Kennedy, Jr, W. E.; Watson, E. C.; Murphy, D. W.; Harrer, B. J.; Harty, R.; Aldrich, J. M.

    1981-05-01

    This report contains the results of a study sponsored by the U.S. Nuclear Regulatory Commission (NRC) of removable surface contamination on radioactive materials transportation containers. The purpose of the study is to provide information to the NRC during their review of existing regulations. Data was obtained from both industry and literature on three major topics: 1) radiation doses, 2) economic costs, and 3) contamination frequencies. Containers for four categories of radioactive materials are considered including radiopharmaceuticals, industrial sources, nuclear fuel cycle materials, and low-level radioactive waste. Assumptions made in this study use current information to obtain realistic yet conservative estimates of radiation dose and economic costs. Collective and individual radiation doses are presented for each container category on a per container basis. Total doses, to workers and the public, are also presented for spent fuel cask and low-level waste drum decontamination. Estimates of the additional economic costs incurred by lowering current limits by factors of 10 and 100 are presented. Current contamination levels for each category of container are estimated from the data collected. The information contained in this report is designed to be useful to the NRC in preparing their recommendations for new regulations.

  12. Simple surface foam application enhances bioremediation of oil-contaminated soil in cold conditions.

    Science.gov (United States)

    Jeong, Seung-Woo; Jeong, Jongshin; Kim, Jaisoo

    2015-04-09

    Landfarming of oil-contaminated soil is ineffective at low temperatures, because the number and activity of micro-organisms declines. This study presents a simple and versatile technique for bioremediation of diesel-contaminated soil, which involves spraying foam on the soil surface without additional works such as tilling, or supply of water and air. Surfactant foam containing psychrophilic oil-degrading microbes and nutrients was sprayed twice daily over diesel-contaminated soil at 6 °C. Removal efficiencies in total petroleum hydrocarbon (TPH) at 30 days were 46.3% for landfarming and 73.7% for foam-spraying. The first-order kinetic biodegradation rates for landfarming and foam-spraying were calculated as 0.019 d(-1) and 0.044 d(-1), respectively. Foam acted as an insulating medium, keeping the soil 2 °C warmer than ambient air. Sprayed foam was slowly converted to aqueous solution within 10-12h and infiltrated the soil, providing microbes, nutrients, water, and air for bioaugmentation. Furthermore, surfactant present in the aqueous solution accelerated the dissolution of oil from the soil, resulting in readily biodegradable aqueous form. Significant reductions in hydrocarbon concentration were simultaneously observed in both semi-volatile and non-volatile fractions. As the initial soil TPH concentration increased, the TPH removal rate of the foam-spraying method also increased. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Nickel, Lead and Zinc Contamination in the Surface Sediments of Agh Gel Wetland, Iran

    Directory of Open Access Journals (Sweden)

    Soheil Sobhan Ardakani

    2016-07-01

    Full Text Available Background & Aims of the Study: Due to the increased human activities around the Agh Gel wetland, this study aimed to measured accumulations of heavy metals (Ni, Pb and Zn in the surface sediment samples taken from this wetland. Materials & Methods: Samples were taken from 10 stations and exposed to bulk digestion and chemical partitioning. Finally, Ni, Pb and Zn concentrations were monitored with ICP-OES in the sediments. Also, geo-accumulation index, contamination factor and pollution load index were used to evaluate the magnitude of contaminants in the sediment profile. Results: The results showed, the average of metal concentration in samples (mg kg-1 wet weight were 34.20±3.58 for Ni, 25.37±2.52 for Pb and 127.20±15.21 for Zn, respectively. Therefore, the pattern of metal concentrations in sediment was determined as Zinc>Nickel >Lead. According to the mean I-geo values, sediments' qualities are classified as unpolluted category for Ni and Pb. Also, sediment's quality is classified as unpolluted to moderately polluted for Zn. The CF values for all elements are classified as moderate contamination. The PLI values indicated that metal pollution exists for all sampling stations. Conclusions: The obtained results indicated that the Agh Gel wetland has a potential to threaten by chemical pollutants such as agricultural effluent. So, in order to preserve the environment of the Agh Gel wetland from deterioration, monitoring of water and sediment qualities is recommended periodically.

  14. Molecular-level removal of proteinaceous contamination from model surfaces and biomedical device materials by air plasma treatment.

    Science.gov (United States)

    Banerjee, K K; Kumar, S; Bremmell, K E; Griesser, H J

    2010-11-01

    Established methods for cleaning and sterilising biomedical devices may achieve removal of bioburden only at the macroscopic level while leaving behind molecular levels of contamination (mainly proteinaceous). This is of particular concern if the residue might contain prions. We investigated at the molecular level the removal of model and real-life proteinaceous contamination from model and practical surfaces by air plasma (ionised air) treatment. The surface-sensitive technique of X-ray photoelectron spectroscopy (XPS) was used to assess the removal of proteinaceous contamination, with the nitrogen (N1s) photoelectron signal as its marker. Model proteinaceous contamination (bovine serum albumin) adsorbed on to a model surface (silicon wafer) and the residual proteinaceous contamination resulting from incubating surgical stainless steel (a practical biomaterial) in whole human blood exhibited strong N1s signals [16.8 and 18.5 atomic percent (at.%), respectively] after thorough washing. After 5min air plasma treatment, XPS detected no nitrogen on the sample surfaces, indicating complete removal of proteinaceous contamination, down to the estimated XPS detection limit 10ng/cm(2). Applying the same plasma treatment, the 7.7at.% nitrogen observed on a clinically cleaned dental bur was reduced to a level reflective of new, as-received burs. Contact angle measurements and atomic force microscopy also indicated complete molecular-level removal of the proteinaceous contamination upon air plasma treatment. This study demonstrates the effectiveness of air plasma treatment for removing proteinaceous contamination from both model and practical surfaces and offers a method for ensuring that no molecular residual contamination such as prions is transferred upon re-use of surgical and dental instruments. Crown Copyright © 2010. Published by Elsevier Ltd. All rights reserved.

  15. PROCEEDINGS WITH CONTAMINATED INDUSTRIAL SITES IN TERMS OF NEW LEGISLATION – PART I. HISTORICAL POLLUTION OF THE EARTH'S SURFACE

    Directory of Open Access Journals (Sweden)

    Magdalena Paulina Wiśniewska

    2017-02-01

    Full Text Available This article shows a way of dealing with the industrial areas, where historical contamination of the earth’s surface occurred, together with an indication of the proper remediation method selection. Public Administration authorities, including the Regional Director of Environmental Protection (RDOŚ and the governor are responsible, among others, for identifying areas where historical contamination or potential historical contamination of the earth's surface occurred. General Director of Environmental Protection is responsible for conducting and updating the registry, which contains information on identified by RDOŚ and district governor contaminated areas. The article discusses also issues related to the duties and responsibilities wielding the earth's surface, as well as the costs of using the environment, taking into account the "polluter pays" principle.

  16. Thallium dispersal and contamination in surface sediments from South China and its source identification.

    Science.gov (United States)

    Liu, Juan; Wang, Jin; Chen, Yongheng; Shen, Chuan-Chou; Jiang, Xiuyang; Xie, Xiaofan; Chen, Diyun; Lippold, Holger; Wang, Chunlin

    2016-06-01

    Thallium (Tl) is a non-essential element in humans and it is considered to be highly toxic. In this study, the contents, sources, and dispersal of Tl were investigated in surface sediments from a riverine system (the western Pearl River Basin, China), whose catchment has been contaminated by mining and roasting of Tl-bearing pyrite ores. The isotopic composition of Pb and total contents of Tl and other relevant metals (Pb, Zn, Cd, Co, and Ni) were measured in the pyrite ores, mining and roasting wastes, and the river sediments. Widespread contamination of Tl was observed in the sediments across the river, with the highest concentration of Tl (17.3 mg/kg) measured 4 km downstream from the pyrite industrial site. Application of a modified Institute for Reference Materials and Measurement (IRMM) sequential extraction scheme in representative sediments unveiled that 60-90% of Tl and Pb were present in the residual fraction of the sediments. The sediments contained generally lower (206)Pb/(207)Pb and higher (208)Pb/(206)Pb ratios compared with the natural Pb isotope signature (1.2008 and 2.0766 for (206)Pb/(207)Pb and (208)Pb/(206)Pb, respectively). These results suggested that a significant fraction of non-indigenous Pb could be attributed to the mining and roasting activities of pyrite ores, with low (206)Pb/(207)Pb (1.1539) and high (208)Pb/(206)Pb (2.1263). Results also showed that approximately 6-88% of Tl contamination in the sediments originated from the pyrite mining and roasting activities. This study highlights that Pb isotopic compositions could be used for quantitatively fingerprinting the sources of Tl contamination in sediments. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Fate factors and emission flux estimates for emerging contaminants in surface waters

    Directory of Open Access Journals (Sweden)

    Hoa T. Trinh

    2016-01-01

    Full Text Available Pharmaceuticals, personal care products, hormones, and wastewater products are emerging environmental concerns for manifold reasons, including the potential of some compounds found in these products for endocrine disruption at a very low chronic exposure level. The environmental occurrences and sources of these contaminants in the water, soil, sediment and biota in European nations and the United States are well documented. This work reports a screening-level emission and fate assessment of thirty compounds, listed in the National Reconnaissance of the United States Geological Survey (USGS, 1999–2000 as the most frequently detected organic wastewater contaminants in U.S. streams and rivers. Estimations of the surface water fate factors were based on Level II and Level III multimedia fugacity models for a 1000 km2 model environment, the size of a typical county in the eastern United States. The compounds are categorized into three groups based upon the sensitivity of their predicted surface water fate factors to uncertainties in their physicochemical property values and the landscape parameters. The environmental fate factors, mass distributions, and loss pathways of all of the compounds are strongly affected by their assumed modes of entry into the environment. It is observed that for thirteen of the thirty organic wastewater contaminants most commonly detected in surface waters, conventional treatment strategies may be ineffective for their removal from wastewater effluents. The surface water fate factors predicted by the fugacity models were used in conjunction with the surface water concentrations measured in the USGS reconnaissance to obtain emission flux estimates for the compounds into U.S. streams and rivers. These include estimated fluxes of 6.8 × 10−5 to 0.30 kg/h km2 for the biomarker coprostanol; 1.7 × 10−5 to 6.5 × 10−5 kg/h km2 for the insect repellent N,N-diethyltoluamide; and 4.3 × 10−6 to 3.1 × 10−5 kg/h km2 for

  18. Wipe-rinse technique for quantitating microbial contamination on large surfaces

    Science.gov (United States)

    Kirschner, L. E.; Puleo, J. R.

    1979-01-01

    The evaluation of an improved wipe-rinse technique for the bioassay of large areas was undertaken due to inherent inadequacies in the cotton swab-rinse technique to which assay of spacecraft is currently restricted. Four types of contamination control cloths were initially tested. A polyester-bonded cloth (PBC) was selected for further evaluation because of its superior efficiency and handling characteristics. Results from comparative tests with PBC and cotton swabs on simulated spacecraft surfaces indicated a significantly higher recovery efficiency for the PBC than for the cotton (90.4 versus 75.2%). Of the sampling area sites studied, PBC was found to be most effective on surface areas not exceeding 0.74 sq m (8.0 sq ft).

  19. HTO transfer from contaminated surfaces to the atmosphere: a database for model validation

    International Nuclear Information System (INIS)

    Davis, P.A.; Amiro, B.D.; Workman, W.J.G.; Corbett, B.J.

    1996-12-01

    This report comprises a detailed database that can be used to validate models of the emission of tritiated water vapour (HTO) from natural contaminated surfaces to the atmosphere. The data were collected in 1992 July during an intensive field study based on the flux-gradient method of micrometeorology. The measurements were made over a wetland area at the Chalk River Laboratories, and over a grassed field near the Pickering Nuclear Generating Station. The study sites, the sampling protocols and the analytical techniques are described in detail, and the measured fluxes are presented. The report also contains a detailed listing of HTO concentrations in air at two heights, HTO concentrations in the source compartments (soil, surface water and vegetation), supporting meteorological data, and various vegetation and soil properties. The uncertainties in all of the measured data are estimated. (author). 15 refs., 23 tabs., 9 figs

  20. Nano-TiO2-based photocatalytic disinfection of environmental surfaces contaminated by meticillin-resistant Staphylococcus aureus.

    Science.gov (United States)

    Petti, S; Messano, G A

    2016-05-01

    Traditional cleaning and disinfection methods are inefficient for complete decontamination of hospital surfaces from meticillin-resistant Staphylococcus aureus (MRSA). Additional methods, such as nano-TiO2-based photocatalytic disinfection (PCD), could be helpful. To evaluate anti-MRSA activity of PCD on polyvinyl chloride (PVC) surfaces in natural-like conditions. Two identical PVC surfaces were used, and nano-TiO2 was incorporated into one of them. The surfaces were contaminated with MRSA isolated from hospitalized patients using a mist sprayer to simulate the mode of environmental contamination caused by a carrier. MRSA cell density was assessed before contamination until 180min after contamination using Rodac plates. The differences between test and control surfaces in terms of MRSA density and log MRSA density reduction were assessed using parametric and non-parametric statistical tests. Five strains were tested, and each strain was tested five times. The highest median MRSA densities [46.3 and 43.1 colony-forming units (cfu)/cm(2) for control and test surfaces, respectively] were detected 45min after contamination. Median MRSA densities 180min after contamination were 10.1 and 0.7cfu/cm(2) for control and test surfaces, respectively (Pdisinfectant activity remained stable throughout the 25 testing occasions, despite between-test cleaning and disinfection. The anti-MRSA activity of PCD was compatible with the benchmark for surface hygiene in hospitals (surfaces. However, for clinical surfaces, PCD should be regarded as supplemental to conventional decontamination procedures, rather than an alternative. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  1. Genetic Variants in TAP Are Associated with High-Grade Cervical Neoplasia

    Science.gov (United States)

    Einstein, Mark H.; Leanza, Suzanne; Chiu, Lydia G.; Schlecht, Nicolas F.; Goldberg, Gary L.; Steinberg, Bettie M.; Burk, Robert D.

    2018-01-01

    Purpose The transporter associated with antigen processing (TAP) is essential in assembling MHC-I proteins. Human papillomavirus (HPV) evades immune recognition by decreasing class I MHC cell surface expression through down-regulation of TAP1 levels. Consistent with heterogeneity in MHC expression is the individual variability in clearing detectable HPV infections. Genetic polymorphisms in TAP genes may affect protein structure, function, and the ability to clear HPV infection. Experimental Design Case-control study of women with cervical intraepithelial neoplasia (CIN) II or III (n = 114) and women without high-grade CIN (n = 366). Five nonsynonymous single nucleotide polymorphisms (SNP) in TAP1 and TAP2 were genotyped using DNA collected in cervicovaginal lavage samples using microsphere array technology (Luminex ×MAP). HPV typing was done using a PCR-based system with MY09/MY11 primers. TAP1 and TAP2 SNPs were validated by direct sequencing. Results Differences in allele distribution between women with high-grade cervical neoplasia and women without was seen for TAP1 I333V (P = 0.02) and TAP1 D637G (p = 0.01).The odds ratios (OR) for CIN III were significantly lower among carriers of the TAP1 I333V polymorphism (OR, 0.28; 95% confidence interval, 0.1-0.8), and TAP1 D637G polymorphism (OR, 0.27; 95% confidence interval, 0.1-0.7). These associations remained significant even after restricting the evaluation to women who were positive for high-risk HPV types. Conclusions In addition to the down-regulation of MHC-1 by oncogenic HPV, HPV pathogenesis might be facilitated by polymorphisms in the TAP proteins. Identifying TAP polymorphisms may potentially be used to identify women less susceptible to progression to high-grade CIN and cervical cancer. PMID:19188174

  2. 49 CFR 192.151 - Tapping.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Tapping. 192.151 Section 192.151 Transportation... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Design of Pipeline Components § 192.151 Tapping. (a) Each mechanical fitting used to make a hot tap must be designed for at least the operating pressure of...

  3. Evaluation and assessment of baseline metal contamination in surface sediments from the Bernam River, Malaysia.

    Science.gov (United States)

    Kadhum, Safaa A; Ishak, Mohd Yusoff; Zulkifli, Syaizwan Zahmir

    2016-04-01

    The Bernam River is one of the most important rivers in Malaysia in that it provides water for industries and agriculture located along its banks. The present study was conducted to assess the level of contamination of heavy metals (Cd, Ni, Cr, Sn, and Fe) in surface sediments in the Bernam River. Nine surface sediment samples were collected from the lower, middle, and upper courses of the river. The results indicated that the concentrations of the metals decreased in the order of Sn > Cr > Ni > Fe > Cd (56.35, 14.90, 5.3, 4.6, and 0.62 μg/g(1) dry weight). Bernam River sediments have moderate to severe enrichment for Sn, moderate for Cd, and no enrichment for Cr, Ni, and Fe. The contamination factor (CF) results demonstrated that Cd and Sn are responsible for the high contamination. The pollution load index (PLI), for all the sampling sites, suggests that the sampling stations were generally unpolluted with the exception of the Bagan Tepi Sungai, Sabak Bernam, and Tanjom Malim stations. Multivariate techniques including Pearson's correlation and hierarchical cluster analysis were used to apportion the various sources of the metals. The results suggested that the sediment samples collected from the upper course of the river had lower metal concentrations, while sediments in the middle and lower courses of the river had higher metal concentrations. Therefore, our results can be useful as a baseline data for government bodies to adopt corrective measure on the issues related to heavy metal pollution in the Bernam River in the future.

  4. Heavy metal contamination in surface sediments of Yangtze River intertidal zone: An assessment from different indexes

    International Nuclear Information System (INIS)

    Zhang Weiguo; Feng Huan; Chang Jinna; Qu Jianguo; Xie Hongxia; Yu Lizhong

    2009-01-01

    Surface sediments (0-5 cm) from 59 stations within the Yangtze River intertidal zone (YRIZ) were sampled for metal contamination analysis in April and August 2005. The concentrations ranged (in mg kg -1 dry weight): Al, 40,803-97,213; Fe, 20,538-49,627; Cd, 0.12-0.75; Cr, 36.9-173; Cu, 6.87-49.7; Mn, 413-1,112; Ni, 17.6-48.0; Pb, 18.3-44.1; and Zn, 47.6-154; respectively. Among the 59 sampling stations, enrichment factors (EF) indicate enrichment of Cd (52 stations), Cr (54 stations), Cu (5 stations), Ni (26 stations), Pb (5 stations) and Zn (5 stations). Geoaccumulation indexes (I geo ) also suggest individual metal contamination in localized areas. This study indicates that Cd, Cr and Ni enrichment in the YRIZ sediment is widespread whereas Cu, Mn, Pb and Zn enrichment is localized or nonexistent. Factor and cluster analyses indicate that Cd is associated with total organic carbon whereas Cu, Cr, Ni, Pb and Zn have a close association with Mn. - Surface sediment metal enrichment is evidenced for Cd, Cr and Ni in the Yangtze River intertidal zone.

  5. Measurements of the spatial distribution of tritium in air above a chronically contaminated surface

    International Nuclear Information System (INIS)

    Workman, W.J.G.; Davis, P.A.; Wood, M.J.; Barry, P.J.

    1993-01-01

    Tritium in air (HTO) concentrations were measured over a 13 month period above a surface that is chronically contaminated by tritium-bearing groundwater from a waste management area. The measurements were made using passive diffusion samplers, which were sited at six locations (about 100 m apart) at 0.15, 0.9, and 1.8 m above ground level. The diffusion samplers were compact, sampled at a known rate, and required no external power source. They are ideal for remote locations and require a minimum of effort to collect and analyze the data. HTO-in-air concentration peaked in the summer at 500-1500 Bq.m -3 and decreased in the winter to 1-120 Bq.m -3 . In general, concentration decreased with height above ground level, implying that HTO is being lost from the surface to the atmosphere. The flux of tritium to the atmosphere must, therefore, be taken into account to estimate the tritium mass balance for a contaminated area. (Author) 3 figs., 5 tabs., 10 refs

  6. Guidance and methods for satisfying low specific activity material and surface contaminated object regulatory requirements

    International Nuclear Information System (INIS)

    Pope, R.B.; Shappert, L.B.; Michelhaugh, R.D.; Boyle, R.W.; Easton, E.P.; Coodk, J.R.

    1998-01-01

    The U.S. Department of Transportation (DOT) and the U.S. Nuclear Regulatory Commission (NRC) have prepared a comprehensive set of draft guidance for shippers and inspectors to use when applying the newly imposed regulatory requirements for low specific activity (LSA) material and surface contaminated objects (SCOs). These requirements represent significant departures in some areas from the manner in which these materials and objects were regulated by the earlier versions of the regulations. The proper interpretation and application of the regulatory criteria can require a fairly complex set of decisions be made. To assist those trying these regulatory requirements, a detailed set of logic-flow diagrams representing decisions related to multiple factors were prepared and included in the draft report for comment on Categorizing and Transporting Low Specific Activity Materials and Surface Contaminated Objects, (DOT/NRC, 1997). These logic-flow diagrams, as developed, are specific to the U.S. regulations, but were readily adaptable to the IAEA regulations. The diagrams have been modified accordingly and tied directly to specific paragraphs in IAEA Safety Series No. 6. This paper provides the logic-flow diagrams adapted in the IAEA regulations, and demonstrated how these diagrams can be used to assist consignors and inspectors in assessing compliance of shipments with the LSA material and SCO regulatory requirements. (authors)

  7. Solutal Marangoni flows of miscible liquids drive transport without surface contamination

    Science.gov (United States)

    Kim, Hyoungsoo; Muller, Koen; Shardt, Orest; Afkhami, Shahriar; Stone, Howard A.

    2017-11-01

    Mixing and spreading of different liquids are omnipresent in nature, life and technology, such as oil pollution on the sea, estuaries, food processing, cosmetic and beverage industries, lab-on-a-chip devices, and polymer processing. However, the mixing and spreading mechanisms for miscible liquids remain poorly characterized. Here, we show that a fully soluble liquid drop deposited on a liquid surface remains as a static lens without immediately spreading and mixing, and simultaneously a Marangoni-driven convective flow is generated, which are counterintuitive results when two liquids have different surface tensions. To understand the dynamics, we develop a theoretical model to predict the finite spreading time and length scales, the Marangoni-driven convection flow speed, and the finite timescale to establish the quasi-steady state for the Marangoni flow. The fundamental understanding of this solutal Marangoni flow may enable driving bulk flows and constructing an effective drug delivery and surface cleaning approach without causing surface contamination by immiscible chemical species.

  8. SUDOQU: a new dose model to derive criteria for surface contamination of non-food (consumer) goods, containers and conveyances

    International Nuclear Information System (INIS)

    Van Dillen, Teun

    2015-01-01

    The Fukushima nuclear accident (Japan, 11 March 2011) revealed the need for well-founded criteria for surface contamination and associated screening levels related to the import of non-food (consumer) goods, containers and conveyances. The only available European-harmonised criteria are those laid down in the IAEA transport regulations, but these criteria date back from the early 1960's and only apply to the safe transport of radioactive materials. The main problem is that a generic dose-assessment model for consumer products is missing. Therefore, RIVM (National Institute for Public Health and the Environment) developed a new methodology entitled SUDOQU (Surface Dose Quantification) to calculate the annual effective dose for both consumers and non-radiological workers, addressing issues of removability of surface contamination. The methodology can be used to derive criteria and screening levels for surface contamination and could serve as a useful tool for policy-makers and radiation-protection specialists. (authors)

  9. Bilateral transversus abdominis plane (TAP) block with 24 hours ropivacaine infusion via TAP catheters

    DEFF Research Database (Denmark)

    Petersen, Pernille L; Hilsted, Karen L; Dahl, Jørgen B

    2013-01-01

    The analgesic effect of a TAP block has been investigated in various surgical settings. There are however limited information about block level and block duration. Furthermore, there is a lack of information about continuous TAP block after ultrasound-guided posterior TAP blocks.The aim of this d...... of this double-blind randomized study was therefore to investigate the effect of an ultrasound-guided posterior TAP block with 24 hours local anesthetic infusion via a TAP catheter....

  10. Beta Autoradiography. An analytical technique to investigate radionuclides contamination on surface

    International Nuclear Information System (INIS)

    Ficher, P.; Goutelard, F.; Siitari-Kauppi, M.

    2012-01-01

    In decommissioning of old buildings and after disposal of nuclear facilities (materials, glove boxes,...), the inventory of the radioactive contamination of various building materials needs to be obtained in order to fix the working condition for dismantling. The challenge of this study was to classify different building materials of a whole research laboratory that was dedicated to research on organic molecules labeled with H-3 and C-14. The problem of waste classification is essential for safety treatment of waste and also for its cost. The analytical technique of beta autoradiography particularly well known for biological researches has been tested to investigate radionuclides contamination on surface. This technique is mainly interesting for beta and alpha emitters but also sensitive to gamma radiation. The first step of this technique is the deposit of a film on the surface of material to be analyzed. Films can be deposited on the ground or also fixed on the walls or even on the ceiling. The film is a plastic sheet covered with an emulsion containing photostimulable crystals and Eu that is activated when the film is exposed on radioactive source. The exposed films are then scanned with the Cyclone Plus equipment to get a digitized image. This image represents the radioactivity of the surface studied. The possibility to re-use the films is very important to investigate a large area. This autoradiography technique has retained our attention for its sensitivity and moreover the possibility of 2-dimensional investigation has been found as a real advantage. However it remains now as a qualitative technique and new studies must be launched to prove its quantitative potentialities. The high spatial resolution was not as important as in biological observation, and the mm resolution is totally sufficient

  11. What Orthopaedic Operating Room Surfaces Are Contaminated With Bioburden? A Study Using the ATP Bioluminescence Assay.

    Science.gov (United States)

    Richard, Raveesh Daniel; Bowen, Thomas R

    2017-07-01

    Contaminated operating room surfaces can increase the risk of orthopaedic infections, particularly after procedures in which hardware implantation and instrumentation are used. The question arises as to how surgeons can measure surface cleanliness to detect increased levels of bioburden. This study aims to highlight the utility of adenosine triphosphate (ATP) bioluminescence technology as a novel technique in detecting the degree of contamination within the sterile operating room environment. What orthopaedic operating room surfaces are contaminated with bioburden? When energy is required for cellular work, ATP breaks down into adenosine biphosphate (ADP) and phosphate (P) and in that process releases energy. This process is inherent to all living things and can be detected as light emission with the use of bioluminescence assays. On a given day, six different orthopaedic surgery operating rooms (two adult reconstruction, two trauma, two spine) were tested before surgery with an ATP bioluminescence assay kit. All of the cases were considered clean surgery without infection, and this included the previously performed cases in each sampled room. These rooms had been cleaned and prepped for surgery but the patients had not been physically brought into the room. A total of 13 different surfaces were sampled once in each room: the operating room (OR) preparation table (both pre- and postdraping), OR light handles, Bovie machine buttons, supply closet countertops, the inside of the Bair Hugger™ hose, Bair Hugger™ buttons, right side of the OR table headboard, tourniquet machine buttons, the Clark-socket attachment, and patient positioners used for total hip and spine positioning. The relative light units (RLUs) obtained from each sample were recorded and data were compiled and averaged for analysis. These values were compared with previously published ATP benchmark values of 250 to 500 RLUs to define cleanliness in both the hospital and restaurant industries. All

  12. Emerging organic contaminants in surface water and groundwater: a first overview of the situation in Italy.

    Science.gov (United States)

    Meffe, Raffaella; de Bustamante, Irene

    2014-05-15

    This paper provides the first review of the occurrence of 161 emerging organic compounds (EOCs) in Italian surface water and groundwater. The reported EOCs belong to the groups of industrials, pharmaceuticals, estrogens and illicit drugs. Occurrence of 137 pesticides was also reported. The reviewed research works have been published between 1997 and 2013. The majority of the studies have been carried out in Northern Italy (n. 30) and to a lower extent in Central Italy (n. 13). Only a limited number of research studies report EOC concentrations in water resources of Southern Italy. The EOCs that have been more frequently studied are in the following descending order, pesticides (16), pharmaceuticals (15), industrials (13), estrogens (7) and illicit drugs (2). Research activities investigating the EOC occurrence in surface water are more numerous than those in groundwater. This is consistent with the higher complexity involved in groundwater sampling and EOC detection. Among the reported EOCs, industrials and pesticides are those occurring in both surface water and groundwater with the highest concentrations (up to 15 × 10(6) and 4.78 × 0(5)ng L(-1), respectively). Concentrations of pharmaceuticals in surface water reach a maximum of 3.59 × 10(3)ng L(-1), whereas only the antimicrobial agent josamycin has been encountered in groundwater with a concentration higher than 100 ng L(-1). Both estrogens and illicit drugs appeared in surface water with concentrations lower than 50 ng L(-1). Groundwater concentrations for estrogens were measured to be below the detection limits, whereas illicit drugs have so far not been studied in groundwater. The present review reveals the serious contamination status of Italian surface water and groundwater especially by pesticides, industrials and to a lower extent by pharmaceuticals and the necessity to foster the research on EOC occurrence in Italian water resources, in particular in Southern Italy where a limited number of

  13. A study on EUV reticle surface molecular contamination under different storage conditions in a HVM foundry fab

    Science.gov (United States)

    Singh, SherJang; Yatzor, Brett; Taylor, Ron; Wood, Obert; Mangat, Pawitter

    2017-03-01

    The prospect of EUVL (Extreme Ultraviolet Lithography) insertion into HVM (High Volume Manufacturing) has never been this promising. As technology is prepared for "lab to fab" transition, it becomes important to comprehend challenges associated with integrating EUVL infrastructure within existing high volume chip fabrication processes in a foundry fab. The existing 193nm optical lithography process flow for reticle handling and storage in a fab atmosphere is well established and in-fab reticle contamination concerns are mitigated with the reticle pellicle. However EUVL reticle pellicle is still under development and if available, may only provide protection against particles but not molecular contamination. HVM fab atmosphere is known to be contaminated with trace amounts of AMC's (Atmospheric Molecular Contamination). If such contaminants are organic in nature and get absorbed on the reticle surface, EUV photon cause photo-dissociation resulting into carbon generation which is known to reduce multilayer reflectivity and also degrades exposure uniformity. Chemical diffusion and aggregation of other ions is also reported under the e-beam exposure of a EUV reticle which is known to cause haze issues in optical lithography. Therefore it becomes paramount to mitigate absorbed molecular contaminant concerns on EUVL reticle surface. In this paper, we have studied types of molecular contaminants that are absorbed on an EUVL reticle surface under HVM fab storage and handling conditions. Effect of storage conditions (gas purged vs atmospheric) in different storage pods (Dual pods, Reticle Clamshells) is evaluated. Absorption analysis is done both on ruthenium capping layer as well as TaBN absorber. Ru surface chemistry change as a result of storage is also studied. The efficacy of different reticle cleaning processes to remove absorbed contaminant is evaluated as well.

  14. The groundwater contribution to surface water contamination in a region with intensive agricultural land use (Noord-Brabant, The Netherlands)

    International Nuclear Information System (INIS)

    Rozemeijer, J.C.; Broers, H.P.

    2007-01-01

    Traditionally, monitoring of soil, groundwater and surface water quality is coordinated by different authorities in the Netherlands. Nowadays, the European Water Framework Directive (EU, 2000) stimulates an integrated approach of the complete soil-groundwater-surface water system. Based on water quality data from several test catchments, we propose a conceptual model stating that stream water quality at different discharges is the result of different mixing ratios of groundwater from different depths. This concept is used for a regional study of the groundwater contribution to surface water contamination in the Dutch province of Noord-Brabant, using the large amount of available data from the regional monitoring networks. The results show that groundwater is a dominant source of surface water contamination. The poor chemical condition of upper and shallow groundwater leads to exceedance of the quality standards in receiving surface waters, especially during quick flow periods. - Water quality monitoring data show the importance of the groundwater contribution to surface water pollution

  15. Decontamination effects of a simulated contaminated floor surface by a teleoperated mopping system

    International Nuclear Information System (INIS)

    Kim, Ki Ho; Kwon, Hyok Jo; Park, Jang Jin; Yang, Myung Seung

    2004-01-01

    A Tele Operated Mopping System (TOMS) was developed for use in the radioactive zone of the M6 hot-cell of the Irradiated Material Examination Facility (IMEF) at the Korea Atomic Energy Research Institute (KAERI). TOMS was designed to remove contaminated dry particulates, dust, and smears existing on the floor surface of the M6 hot-cell by mopping it in a remote manner. TOMS has three subsystems - a mobile mopping slave located inside the hot-cell, and a mopping master and a control console located outside the hot-cell. The mobile mopping slave consists of a tracked mobile platform, a mopping tool, and a wet mopping cloth, which were constructed in modules to facilitate a maintenance. This paper aims at describing the mopping capability of the developed TOMS - decontamination capability. In this work the decontamination capability is defined by the ratio of the removed contaminated area when the mopping cloth was passed over. The experiment was carried out by varying the speeds of the mopping slave and the roller, while the mopping force driven by the operator was constant. The roller of the mopping tool mounted on the mopping slave was designed to collect the mopping cloth used. The experimental results showed that the speeds of the mopping slave and the roller influence the extent of the decontamination

  16. Dispersion of inorganic contaminants in surface water in the vicinity of Potchefstroom

    Science.gov (United States)

    Manyatshe, A.; Fosso-Kankeu, E.; van der Berg, D.; Lemmer, N.; Waanders, F.; Tutu, H.

    2017-08-01

    Potchefstroom and the neighbouring cities rely mostly on the Mooi River and Vaal River for their water needs. These rivers flow through the gold mining areas and farms, and are therefore likely to be contaminated with substantial amounts of inorganic pollutants. Water was collected along the rivers network, streams, canals and dams in Potchefstroom and the vicinity. The samples were characterized for geochemical parameters, metals and anions concentrations. The results showed high concentrations of potentially toxic elements such as As (4.53 mg/L - 5.74 mg/L), Cd (0.25 mg/L - 0.7 mg/L), Pb (1.14 mg/L - 5.13 mg/L) and U (0.04 mg/L - 0.11 mg/L) which were predominantly found around the mining areas. Elevated concentrations of anions such SO42- and CN- were detected around mining areas while NO3- was dominant near farms. The relatively high levels of anions and metals in the surface water made it unfit for domestic or agricultural use. The study showed that contaminants in mining and agricultural facilities were potentially mobilised, thus impacting the nearby water systems.

  17. Estimation of the amount of surface contamination of a water cooled nuclear reactor by cooling water analysis

    Energy Technology Data Exchange (ETDEWEB)

    Nagy, G. [KFKI Atomic Energy Research Institute, P.O. Box 49, Budapest H-1525 (Hungary)]. E-mail: nagyg@sunserv.kfki.hu; Somogyi, A. [KFKI Atomic Energy Research Institute, P.O. Box 49, Budapest H-1525 (Hungary); Patek, G. [Paks Nuclear Power Plant, P.O. Box 71, Paks H-7031 (Hungary); Pinter, T. [Paks Nuclear Power Plant, P.O. Box 71, Paks H-7031 (Hungary); Schiller, R. [KFKI Atomic Energy Research Institute, P.O. Box 49, Budapest H-1525 (Hungary)

    2007-06-15

    Calculations, based upon on-the-spot measurements, were performed to estimate the contamination of NPP primary circuit and spent fuel storage pool solid surfaces via the composition of the cooling water in connection with a non-nuclear incident in the Paks NPP. Thirty partially burnt-up fuel element bundles were damaged during a cleaning process, an incident which resulted in the presence of fission products in the cooling water of the cleaning tank (CT) situated in a separate pool (P1). Since this medium was in contact for an extended period of time with undamaged fuel elements to be used later and also with other structural materials of the spent fuel storage pool (SP), it was imperative to assess the surface contamination of these latter ones with a particular view to the amount of fission material. In want of direct methods, one was restricted to indirect information which rested mainly on the chemical and radiochemical data of the cooling water. It was found that (i) the most important contaminants were uranium, plutonium, cesium and cerium; (ii) after the isolation of P1 and SP and an extended period of filtering the only important contaminants were uranium and plutonium; (iii) the surface contamination of the primary circuit (PC) was much lower than that of either SP or P1; (iv) some 99% of the contamination was removed from the water by the end of the filtering process.

  18. Multicenter evaluation of a new closed system drug-transfer device in reducing surface contamination by antineoplastic hazardous drugs.

    Science.gov (United States)

    Bartel, Sylvia B; Tyler, Timothy G; Power, Luci A

    2018-02-15

    Results of a study to evaluate the effectiveness of a recently introduced closed system drug-transfer device (CSTD) in reducing surface contamination during compounding and simulated administration of antineoplastic hazardous drugs (AHDs) are reported. Wipe samples were collected from 6 predetermined surfaces in compounding and infusion areas of 13 U.S. cancer centers to establish preexisting levels of surface contamination by 2 marker AHDs (cyclophosphamide and fluorouracil). Stainless steel templates were placed over the 6 previously sampled surfaces, and the marker drugs were compounded and infused per a specific protocol using all components of the CSTD. Wipe samples were collected from the templates after completion of tasks and analyzed for both marker AHDs. Aggregated results of wipe sampling to detect preexisting contamination at the 13 study sites showed that overall, 66.7% of samples (104 of 156) had detectable levels of at least 1 marker AHD; subsequent testing after CSTD use per protocol found a sample contamination rate of 5.8% (9 of 156 samples). In the administration areas alone, the rate of preexisting contamination was 78% (61 of 78 samples); with use of the CSTD protocol, the contamination rate was 2.6%. Twenty-six participants rated the CSTD for ease of use, with 100% indicating that they were satisfied or extremely satisfied. A study involving a rigorous protocol and 13 cancer centers across the United States demonstrated that the CSTD reduced surface contamination by cyclophosphamide and fluorouracil during compounding and simulated administration. Participants reported that the CSTD was easy to use. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  19. Laser-induced damage of fused silica at 355 and 1065 nm initiated at aluminum contamination particles on the surface

    International Nuclear Information System (INIS)

    Genin, F.Y.; Michlitsch, K.; Furr, J.; Kozlowski, M.R.; Krulevitch, P.

    1997-01-01

    1-μm thick circular dots, 10-250 μm dia, were deposited onto 1.14 cm thick fused silica windows by sputtering Al through a mask. Al shavings were also deposited on the windows to investigate effects of particle-substrate adhesion. The silica windows were then illuminated repetitively using a 3-ns, 355 nm and an 8.6-ns, 1064 nm laser. The tests were conducted at near normal incidence with particles on input and output surfaces of the windows. During the first shot, a plasma ignited at the metal particle and damage initiated on the fused silica surface. The morphology of the damage at the metal dots were reproducible but different for input and output surface contamination. For input surface contamination, minor damage occurred where the particle was located; such damage ceased to grow with the removal of contaminant material. More serious damage (pits and cracks) was initiated on the output surface (especially at 355 nm) and grew to catastrophic proportions after few shots. Output surface contaminants were usually ejected on the initial shot, leaving a wave pattern on the surface. No further damage occurred with subsequent shots unless a shot (usually the first shot) cracked the surface; such behavior was mostly observed at 355 nm and occasionally for large shavings at 1064 nm. The size of the damaged area scaled with the size of the particle (except when catastrophic damage occurred). Onset of catastrophic damage on output surface occurred only when particles exceeded a critical size. Damage behavior of the sputtered dots was found to be qualitatively similar to that of the shavings. The artificial contamination technique accelerated the study by allowing better control of the test conditions

  20. Agricultural contamination in soil-groundwater-surface water systems in the North China Plain

    DEFF Research Database (Denmark)

    Brauns, Bentje

    of fertilizers and pesticides. Unfortunately, the lack of regulation or oversight has led to the overuse of these agrochemicals: current application rates (in kg/ha) are two- to threefold higher than in most developed countries, and this is taking its toll on the environment. Problems include severe surface...... water and groundwater pollution by nitrogen and pesticides, soil degradation, bioaccumulation of toxic compounds, and more. It is crucial for China to do improve the safeguarding of its water resources in order to sustain the livelihoods of its people and ensure safe supply of drinking water. Recently......-groundwater interaction was chosen, and field work was performed between October 2012 and March 2014. Results from the field study showed that fertilizer inputs were excessive, and could be reduced substantially. Contaminated river water was infiltrating – and carrying ammonium pollution – into the shallow groundwater...

  1. The Mobile Surface Contamination Monitor II environmental radiological characterization utilizing GPS/GIS technologies

    International Nuclear Information System (INIS)

    Wendling, M.A.

    1993-05-01

    Time, cost, and most importantly quality of data are the three factors to measure the success of field radiological characterizations. The application of coupling radiation detection instrumentation to a GPS receiver has dramatically increased the data quality achievable compared to traditional environmental radiological survey methods. Improvements in verifying adequate spatial coverage of an area while collecting data and at,the same time reducing field time requirements can be realized. Data acquired during the recent implementation of the Mobile Surface Contamination Monitor 11 (MSCM-11) will be presented to demonstrate the advantages of this system over traditional radiological survey methods. The comparison will include time and manpower requirements. Linking the complimentary GPS, GIS and radiation detection technologies on a mobile tractor based platform has provided a tool to provide radiological characterization data faster, cheaper, and better to assist in the Environmental Restoration Mission of the Hanford Site

  2. Global occurrence of anti-infectives in contaminated surface waters: Impact of income inequality between countries.

    Science.gov (United States)

    Segura, Pedro A; Takada, Hideshige; Correa, José A; El Saadi, Karim; Koike, Tatsuya; Onwona-Agyeman, Siaw; Ofosu-Anim, John; Sabi, Edward Benjamin; Wasonga, Oliver V; Mghalu, Joseph M; dos Santos Junior, Antonio Manuel; Newman, Brent; Weerts, Steven; Yargeau, Viviane

    2015-07-01

    The presence anti-infectives in environmental waters is of interest because of their potential role in the dissemination of anti-infective resistance in bacteria and other harmful effects on non-target species such as algae and shellfish. Since no information on global trends regarding the contamination caused by these bioactive substances is yet available, we decided to investigate the impact of income inequality between countries on the occurrence of anti-infectives in surface waters. In order to perform such study, we gathered concentration values reported in the peer-reviewed literature between 1998 and 2014 and built a database. To fill the gap of knowledge on occurrence of anti-infectives in African countries, we also collected 61 surface water samples from Ghana, Kenya, Mozambique and South Africa, and measured concentrations of 19 anti-infectives. A mixed one-way analysis of covariance (ANCOVA) model, followed by Turkey-Kramer post hoc tests was used to identify potential differences in anti-infective occurrence between countries grouped by income level (high, upper-middle and lower-middle and low income) according to the classification by the World Bank. Comparison of occurrence of anti-infectives according to income level revealed that concentrations of these substances in contaminated surface waters were significantly higher in low and lower-middle income countries (p=0.0001) but not in upper-middle income countries (p=0.0515) compared to high-income countries. We explained these results as the consequence of the absence of or limited sewage treatment performed in lower income countries. Furthermore, comparison of concentrations of low cost anti-infectives (sulfonamides and trimethoprim) and the more expensive macrolides between income groups suggest that the cost of these substances may have an impact on their environmental occurrence in lower income countries. Since wastewaters are the most important source of contamination of anti-infectives and other

  3. Radioecological state of some surface water systems of contaminated areas of both Gomel and Mogilev Regions

    International Nuclear Information System (INIS)

    Datskevich, P. I.; Komissariv, F. D.; Khvale', O. D.; Basharina, L. P.; Lobach, I. L.

    1997-01-01

    The radioecological situation of different ecosystems of Belarus and their components has been analysed. Such components of the surface water ecosystems as water, suspensions, sediments and soils of water-collection areas were used for the investigation of the content of cesium 137 and strontium 90. The received data were given since 1990. The content of cesium 137 and strontium 90 in the components of water ecosystems was counted in the laboratory conditions by means of standard methods of beta radiometry, semiconductor gamma spectrometry and radiochemistry. The error of measurement of radioactivity was not higher than 25 and 35% for cesium 137 and strontium 90 accordingly. Water ecosystems were distinguished by the state of contamination of water-collection areas and hydrological parameters. These and some other reasons considered in the article influence on the character of cesium 137 and strontium 90 behaviour in water ecosystems

  4. Absorption and backscatter of internal conversion electrons in the measurements of surface contamination of 137Cs

    International Nuclear Information System (INIS)

    Yunoki, A.; Kawada, Y.; Yamada, T.; Unno, Y.; Sato, Y.; Hino, Y.

    2013-01-01

    We measured 4π and 2π counting efficiencies for internal conversion electrons (ICEs), gross β-particles and also β-rays alone with various source conditions regarding absorber and backing foil thickness using e-X coincidence technique. Dominant differences regarding the penetration, attenuation and backscattering properties among ICEs and β-rays were revealed. Although the abundance of internal conversion electrons of 137 Cs- 137 Ba is only 9.35%, 60% of gross counts may be attributed to ICEs in worse source conditions. This information will be useful for radionuclide metrology and for surface contamination monitoring. - Highlights: • Counting efficiencies for internal conversion electrons from 137 Cs were measured, and compared with those for β-rays. • Electron-X coincidence technique was employed. • A thin NaI(Tl) scintillation detector was used for X-ray detection. • Backscattering fractions of electrons and beta particles were studied by similar experiments

  5. Risk assessing heavy metals in the groundwater-surface water interface at a contaminated site

    DEFF Research Database (Denmark)

    Bigi, Giovanni; McKnight, Ursula S.; Bjerg, Poul Løgstrup

    such as surface water and groundwater (EC, 2017). The current study quantified and assessed the contamination of As, Cd, Cr, Cu, Ni, Pb and Zn in the shallow aquifer, hyporheic zone, stream water and streambed sediments at Rådvad site, a former metal manufacturing industrial area located in Denmark, investigating...... in the soil). Stream water was sampled in 12 points, while groundwater was sampled in 4 wells close to the stream where the interaction was suspected. Sediments and hyporheic zone were sampled in pair, where upward hydraulic heads have been detected. A drain discharging in the river was also sampled....... Sediments were divided in different layers and both heavy metal total concentration and chemical partitioning were analysed. Redox species and dissolved organic matter were also analysed in the water samples, while fraction of organic carbon was investigated in the extracted sediments. Results showed a high...

  6. Removal of Airborne Contaminants from a Surface Tank by a Push-Pull System

    DEFF Research Database (Denmark)

    Heiselberg, Per; Topp, Claus

    Open surface tanks are used in many industrial processes, and local exhaust systems are often designed to capture and remove toxic fumes diffused from materials in the tanks prior to their escape into the workplace environment. The push-pull system seems to be the most efficient local exhaust...... system, but proper design is required to ensure health and safety of the workers and, furthermore, it is very desirable from an energy conservation point of view to determine an optimum and -an efficient design of push-pull hoods which can exhaust all contaminants with a minimum quantity of volume flow....... The paper describes and discusses different design methods and compares designed values with results from a measurement series of push-pull system efficiency....

  7. The technique for determination of surface contamination by uranium on U3Si2-Al plate-type fuel elements

    International Nuclear Information System (INIS)

    Li Shulan; He Fengqi; Wang Qingheng; Han Jingquan

    1993-04-01

    The NDT method for determining the surface contamination by uranium on U 3 Si 2 -Al plate-type fuel elements, the process of standard specimen preparation and the graduation curve are described. The measurement results of U 3 Si 2 -Al plate-type fuel elements show that the alpha counting method to measure the surface contamination by uranium on fuel plate is more reliable. The UB-1 type surface contamination meter, which was recently developed, has many advantages such as high sensitivity to determine the uranium pollution, short time in measuring, convenience for operation, and the minimum detectable amount of uranium is 5 x 10 -10 g/cm 2 . The measuring device is controlled by a microcomputer. Besides data acquisition and processing, it has functions of statistics, output data on terminal or to printer and alarm. The procedures of measurement are fully automatic. All of these will meet the measuring needs in batch process

  8. Contribution of the surface contamination of uranium-materials on the quantitative analysis results by electron probe microbeam analysis

    International Nuclear Information System (INIS)

    Bonino, O.; Fournier, C.; Fucili, C.; Dugne, O.; Merlet, C.

    2000-01-01

    The analytical testing of uranium materials is necessary for quality research and development in nuclear industry applications (enrichment, safety studies, fuel, etc). Electron Probe Microbeam Analysis Wavelength Dispersive Spectrometry (EPMA-WDS) is a dependable non-destructive analytical technology. The characteristic X-ray signal is measured to identify and quantify the sample components, and the analyzed volume is about one micron cube. The surface contamination of uranium materials modifies and contributes to the quantitative analysis results of EPMA-WDS. This contribution is not representative of the bulk. A thin oxidized layer appears in the first instants after preparation (burnishing, cleaning) as well as a carbon contamination layer, due to metallographic preparation and carbon cracking under the impact of the electron probe. Several analytical difficulties subsequently arise, including an overlapping line between the carbon Ka ray and the Uranium U NIVOVI ray. Sensitivity and accuracy of the quantification of light elements like carbon and oxygen are also reduced by the presence of uranium. The aim of this study was to improve the accuracy of quantitative analysis on uranium materials by EPMA-WDS by taking account of the contribution of surface contamination. The first part of this paper is devoted to the study of the contaminated surface of the uranium materials U, UFe 2 and U 6 Fe a few hours after preparation. These oxidation conditions are selected so as to reproduce the same contamination surfaces occurring in microprobe analytical conditions. Surface characterization techniques were SIMS and Auger spectroscopy. The contaminated surfaces are shown. They consist of successive layers: a carbon layer, an oxidized iron layer, followed by an iron depletion layer (only in UFe 2 and U 6 Fe), and a ternary oxide layer (U-Fe-O for UFe 2 et U 6 Fe and UO 2+x for uranium). The second part of the paper addresses the estimation of the errors in quantitative

  9. Assessment of drinking water quality at the tap using fluorescence spectroscopy

    OpenAIRE

    Heibati, Masoumeh; Stedmon, Colin A; Stenroth, Karolina; Rauch, Sebastien; Toljander, Jonas; Säve-Söderbergh, Melle; Murphy, Kathleen R.

    2017-01-01

    Treated drinking water may become contaminated while travelling in the distribution system on the way to consumers. Elevated dissolved organic matter (DOM) at the tap relative to the water leaving the treatment plant is a potential indicator of contamination, and can be measured sensitively, inexpensively and potentially on-line via fluorescence and absorbance spectroscopy. Detecting elevated DOM requires potential contamination events to be distinguished from natural fluctuations in the syst...

  10. Mechanisms for surface contamination of soils and bottom sediments in the Shagan River zone within former Semipalatinsk Nuclear Test Site.

    Science.gov (United States)

    Aidarkhanov, A O; Lukashenko, S N; Lyakhova, O N; Subbotin, S B; Yakovenko, Yu Yu; Genova, S V; Aidarkhanova, A K

    2013-10-01

    The Shagan River is the only surface watercourse within the former Semipalatinsk Test Site (STS). Research in the valley of the Shagan River was carried out to study the possible migration of artificial radionuclides with surface waters over considerable distances, with the possibility these radionuclides may have entered the Irtysh River. The investigations revealed that radioactive contamination of soil was primarily caused by the first underground nuclear test with soil outburst conducted at the "Balapan" site in Borehole 1004. The surface nuclear tests carried out at the "Experimental Field" site and global fallout made insignificant contributions to contamination. The most polluted is the area in the immediate vicinity of the "Atomic" Lake crater. Contamination at the site is spatial. The total area of contamination is limited to 10-12 km from the crater piles. The ratio of plutonium isotopes was useful to determine the source of soil contamination. There was virtual absence of artificial radionuclide migration with surface waters, and possible cross-border transfer of radionuclides with the waters of Shagan and Irtysh rivers was not confirmed. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. The physics of Beer Tapping

    OpenAIRE

    Rodriguez-Rodriguez, Javier

    2015-01-01

    The popular bar prank known in colloquial English as beer tapping consists in hitting the top of a beer bottle with a solid object, usually another bottle, to trigger the foaming over of the former within a few seconds. Despite the trick being nown for a long time, to the best of our knowledge, the phenomenon still lacked scientific explanation. Although it seems natural to think that shock-induced cavitation enhances the diffusion of CO2 from the supersaturated bulk liquid into the bub...

  12. A risk-informed basis for establishing non-fixed surface contamination limits for spent fuel transportation casks

    International Nuclear Information System (INIS)

    Rawl, R.R.; Eckerman, K.F.; Bogard, J.S.; Cook, J.R.

    2004-01-01

    The current limits for non-fixed contamination on packages used to transport radioactive materials were introduced in the 1961 edition of the International Atomic Energy Agency (IAEA) transport regulations and were based on radiation protection guidance and practices in use at that time. The limits were based on exposure scenarios leading to intakes of radionuclides by inhalation and external irradiation of the hands. These considerations are collectively referred to as the Fairbairn model. Although formulated over 40 years ago, the model remains unchanged and is still the basis of current regulatory-derived limits on package non-fixed surface contamination. There can also be doses that while not resulting directly from the contamination, are strongly influenced by and attributable to transport regulatory requirements for contamination control. For example, actions necessary to comply with the current derived limits for light-water-reactor (LWR) spent nuclear fuel (SNF) casks can result in significant external doses to workers. This is due to the relatively high radiation levels around the loaded casks, where workers must function during the measurement of contamination levels and while decontaminating the cask. In order to optimize the total dose received due to compliance with cask contamination levels, it is necessary to take into account all the doses that vary as a result of the regulatory limit. Limits for non-fixed surface contamination on spent fuel casks should be established by using a model that considers and optimizes the appropriate exposure scenarios both in the workplace and in the public environment. A risk-informed approach is needed to ensure optimal use of personnel and material resources for SNF-based packaging operations. This paper is a summary of a study sponsored by the US Nuclear Regulatory Commission and performed by Oak Ridge National Laboratory that examined the dose implications for removable surface contamination limits on spent fuel

  13. INDUSTRIAL APPROBATION OF COMBINED COUNTERSINK-TAP TOOL

    Directory of Open Access Journals (Sweden)

    Nurulla M. Vagabov

    2017-01-01

    Full Text Available Abstract. Objectives Based on a critical analysis of the results of complex studies, we set out to demonstrate the advantages, as compared with existing technologies, of a developed technology that uses a new cutting scheme with a combined countersink-tap tool. Methods One way to improve the processing capacity, tool life and quality of a cut thread is to reduce the torque and strain hardening of the processed material by employing a new cutting approach to completely eliminate the friction of the lateral sides of the tooth on the surface of the cut thread. It was necessary for this technology to be checked in real production conditions. Results The conducted production tests of a combined countersink-tap tool with the new cutting scheme developed by the inventors have shown that, as a result of a significant reduction in the torque and a decrease in the strain hardening of the processed material, it is possible to increase the cutting speed and increase labour productivity by more than 2 times as compared with the thread cutting processes using taps with staggered teeth, 1.2 times as compared to taps with a corrected structure, and more than 6 times as compared to standard taps. At the same time, the stability of the tool is increased 3-5 times and the number of breakages is also sharply reduced. Conclusion It has been established that the accuracy of the geometric parameters as well as the strength and quality of the thread surface cut by the combined countersink-tap tool with the new cutting scheme in hard-to-work materials is much higher than the same thread parameters obtained by processing with standard and other known taps. The studies also indicated its high reliability, operability and expediency of application for processing the above-mentioned materials. The advantages of the combined tool also include a reduction in thread cutting time as compared to a separate machining of the threaded hole (countersinking with a standard

  14. Organization of work for prevention of propagation of radioactive contamination, for decontamination of the premise surfaces and individual protective means in case of radiation accident

    International Nuclear Information System (INIS)

    Klochkov, V.N.; Vas'kin, A.G.; Filatova, V.M.

    1995-01-01

    Radiation accident results in radioactive contamination of the surface, clothes and other property. If proper measures are taken, it will prevent propagation of contamination. Decontamination of surfaces - is a complicated and tedious process. The paper has examined the measures of organization and technical aspects of prevention of propagation of radioactive contamination. Methods of decontamination of internal surfaces of premises are demonstrated, organization of the individual protective means is determined. 9 refs

  15. Evaluation of the homogeneity of reference flat sources used in calibration of surface contamination monitors

    International Nuclear Information System (INIS)

    Silva Junior, I.A.; Xavier, M.; Siqueira, P.T.D.; Potiens, M.P.A.

    2014-01-01

    The aim of this study was to re-evaluate the uniformity of the wide area reference sources of the Calibration Laboratory of Instruments (LCI-IPEN) used in the calibration of surface contamination monitors, according the recommendations of the ISO 8769 standard and the NRPB. In this work used six wide area reference sources of 150 cm 2 of 241 Am, 14 C, 36 Cl, 137 Cs, 90 Sr+ 90 Y and 99 Tc with reference dates between 1996 and 1997 and three sources of 100 cm 2 of 14 C, 137 Cs and 60 Co were used with reference dates 2007. Measurements were performed with a radiation monitor of the Thermo, model FH40GX with a pancake probe, model FHZ732GM. We also made several models on paper with the objective of define each measurement position and an aluminum plate with a square hole (6.25 cm 2 ) in its center, allowing the passage of the radiation only through the hole. Each wide area reference source was positioned in setup and measurements were performed in order to cover the entire surface of the source. The values of the uniformity obtained partially confirm previous data obtained in another study conducted by LCI-IPEN, showing that some wide area reference sources 150 cm 2 in disagree with ISO 8769. In the former work, just the source of 241 Am (7.3%) was within the range specified by the standard, now have sources of 241 Am (5.7%), 137 Cs (8.8%), 90 Sr+ 9 '0Y (8, 8%) and 99 Tc (9.2%) with values within the specified uniformity. The sources of 14 C (53.3%) and 36 Cl (16.6%) were outside the specified. The wide area reference sources of 100 cm 2 , show disagreement in values of uniformity of the sources 14 C (46.7%) and 60 Co (10.4%). The values of the uniformity of the wide area reference sources show that some fonts can not be used in calibrations, because not in accordance with the value of uniformity specified in ISO 8769:2010, this is a conditions to believe a laboratory according to ISO 17025, show the laboratory performs its services with a high quality. The

  16. Evaluation of the contribution of contamination of radiotherapy room surfaces in the measure of exposure rate of radioiodine therapy patients

    International Nuclear Information System (INIS)

    Campos, Rafael Ferreira

    2015-01-01

    The contamination of radiotherapy room surfaces is significant and the measures of patient exposure rate are held on the fourth dependencies, relevant questions are raised: the background radiation of the room stay high due to surface contamination, may interfere with the rate of patient exposure at the time of its release? The monitoring site is important to determine whether the patient will be released? The value of the deal activity and the clinical condition of the patient may increase the contamination, influencing the monitoring results? This paper aims to conduct a quantitative analysis of surface contamination of the contribution of therapeutic room at the time is monitored exposure rate from inpatient. Measurements were made regarding the hospitalization of 32 patients with different doses administered activity, age and of both genders. The measurements were performed in the therapeutic rooms at the hospital Brotherhood Santa Casa de Misericordia de Sao Paulo. Exposure rate measurements were performed at the center of the room at 1 meter of the patient on the day of its release. After his release and prior to decontamination, measurements were performed at predetermined landmarks within the therapeutic room. The results revealed that on average background radiation, high due to surface contamination contributes only 2% of the patient dose rate. It can be considered that even with influence of contamination of surfaces, this is insignificant to determine if the patient may or may not be released. This study suggests that the site in which monitoring occurs exposure rate of the patient should not be decisive for liberation thereof. (author)

  17. A prospective survey of air and surface fungal contamination in a medical mycology laboratory at a tertiary care university hospital.

    Science.gov (United States)

    Sautour, Marc; Dalle, Frédéric; Olivieri, Claire; L'ollivier, Coralie; Enderlin, Emilie; Salome, Elsa; Chovelon, Isabelle; Vagner, Odile; Sixt, Nathalie; Fricker-Pap, Véronique; Aho, Serge; Fontaneau, Olivier; Cachia, Claire; Bonnin, Alain

    2009-04-01

    Invasive filamentous fungi infections resulting from inhalation of mold conidia pose a major threat in immunocompromised patients. The diagnosis is based on direct smears, cultural symptoms, and culturing fungi. Airborne conidia present in the laboratory environment may cause contamination of cultures, resulting in false-positive diagnosis. Baseline values of fungal contamination in a clinical mycology laboratory have not been determined to date. A 1-year prospective survey of air and surface contamination was conducted in a clinical mycology laboratory during a period when large construction projects were being conducted in the hospital. Air was sampled with a portable air system impactor, and surfaces were sampled with contact Sabouraud agar plates. The collected data allowed the elaboration of Shewhart graphic charts. Mean fungal loads ranged from 2.27 to 4.36 colony forming units (cfu)/m(3) in air and from 0.61 to 1.69 cfu/plate on surfaces. Strict control procedures may limit the level of fungal contamination in a clinical mycology laboratory even in the context of large construction projects at the hospital site. Our data and the resulting Shewhart graphic charts provide baseline values to use when monitoring for inappropriate variations of the fungal contamination in a mycology laboratory as part of a quality assurance program. This is critical to the appropriate management of the fungal risk in hematology, cancer and transplantation patients.

  18. Improving Satellite Retrieved Infrared Sea Surface Temperatures in Aerosol-Contaminated Regions

    Science.gov (United States)

    Luo, B.; Minnett, P. J.; Szczodrak, G.; Kilpatrick, K. A.

    2017-12-01

    Infrared satellite observations of sea surface temperature (SST) have become essential for many applications in meteorology, climatology, and oceanography. Applications often require high accuracy SST data: for climate research and monitoring an absolute uncertainty of 0.1K and stability of better than 0.04K per decade are required. Tropospheric aerosol concentrations increase infrared signal attenuation and prevent the retrieval of accurate satellite SST. We compare satellite-derived skin SST with measurements from the Marine-Atmospheric Emitted Radiance Interferometer (M-AERI) deployed on ships during the Aerosols and Ocean Science Expeditions (AEROSE) and with quality-controlled drifter temperatures. After match-up with in-situ SST and filtering of cloud contaminated data, the results indicate that SST retrieved from MODIS (Moderate Resolution Imaging Spectroradiometer) aboard the Terra and Aqua satellites have negative (cool) biases compared to shipboard radiometric measurements. There is also a pronounced negative bias in the Saharan outflow area that can introduce SST errors >1 K at aerosol optical depths > 0.5. In this study, we present a new method to derive night-time Saharan Dust Index (SDI) algorithms based on simulated brightness temperatures at infrared wavelengths of 3.9, 10.8 and 12.0 μm, derived using RTTOV. We derived correction coefficients for Aqua MODIS measurements by regression of the SST errors against the SDI. The biases and standard deviations are reduced by 0.25K and 0.19K after the SDI correction. The goal of this study is to understand better the characteristics and physical mechanisms of aerosol effects on satellite retrieved infrared SST, as well as to derive empirical formulae for improved accuracies in aerosol-contaminated regions.

  19. Actinide migration from contaminated soil to surface water at the rocky flats environmental technology site

    International Nuclear Information System (INIS)

    Santschi, Peter H.; Roberts, Kimberly

    2002-01-01

    Surficial soils of the Rocky Flats Environmental Technology Site (RFETS) contain elevated levels of 239,240 Pu and 241 Am due to wind dispersal of soil particles, contaminated in the 1960's by leaking drums stored on the 903 Pad. Over the past 4 years, actinide mobility in the surface environment at RFETS, Golden, Colorado, USA, was examined through field and laboratory experiments. From measurements of total 239,240 Pu and 241 Am concentrations in storm runoff and pond discharge samples, collected during spring and summer times, it was established that most of the actinide transport from contaminated soils to streams occurred in the particulate (0.45μm) and colloidal (3kDa - 0.45μm) phases. Controlled laboratory investigations of soil resuspension, indicated that remobilization of colloid-bound Pu during soil erosion events can be enhanced by humic acids. 2-D Polyacrylamide Gel electrophoresis (PAGE) experiments of radiolabeled colloidal organic and inorganic matter, extracted from RFETS soils, suggested that colloidal Pu, which was focused at pH IEP of 4.5, is mainly associated with organic (humic acids) colloids of 10-15 kDa molecular weight. Pu(IV) oxide and inorganic colloids such as iron and aluminum oxides have pH IEP of 8-10. While some clay minerals also have pH IEP of 3-5, no Al was found coincident with Pu. This finding has important ramifications for possible remediation, erosion controls, and land-management strategies. (author)

  20. Electronic tap-changer for distribution transformers

    CERN Document Server

    Faiz, Jawad

    2011-01-01

    This reference collects all relevant aspects electronic tap-changer and presents them in a comprehensive and orderly manner. It explains logically and systematically the design and optimization of a full electronic tap-changer for distribution transformers. The book provides a fully new insight to all possible structures of power section design and categorizes them comprehensively, including cost factors of the design. In the control section design, the authors review mechanical tap-changer control systems and they present the modeling of a full electronic tap-changer as well as a closed-loop

  1. A Complete Analytical Screening Identifies the Real Pesticide Contamination of Surface Waters

    Science.gov (United States)

    Moschet, Christoph; Wittmer, Irene; Simovic, Jelena; Junghans, Marion; Singer, Heinz; Stamm, Christian; Leu, Christian; Hollender, Juliane

    2014-05-01

    A comprehensive assessment of pesticides in surface waters is challenging due to the large number of potential contaminants. In Switzerland for example, roughly 500 active ingredients are registered as either plant protection agent (PPA) or as biocide. In addition, an unlimited number of transformations products (TPs) can enter or be formed in surfaced waters. Most scientific publications or regulatory monitoring authorities have implemented 15-40 pesticides in their analytics. Only a few TPs are normally included. Interpretations of the surface water quality based on these subsets remains error prone. In the presented study, we carried out a nearly complete analytical screening covering 86% of all polar organic pesticides (from agricultural and urban sources) in Switzerland (300 substances) and 134 TPs with limits of quantification in the low ng/L range. The comprehensive pesticide screening was conducted by liquid-chromatography coupled to high-resolution tandem mass spectrometry. Five medium-sized rivers (Strahler stream order 3-4, catchment size 35-105 km2), containing high percentiles of diverse crops, orchards and urban settlements in their catchments, were sampled from March till July 2012. Nine subsequent time-proportional bi-weekly composite samples were taken in order to quantify average concentrations. In total, 104 different active ingredients could be detected in at least one of the five rivers. Thereby, 82 substances were only registered as PPA, 20 were registered as PPA and as biocide and 2 were only registered as biocide. Within the PPAs, herbicides had the most frequent detections and the highest concentrations, followed by fungicides and insecticides. Most concentrations were found between 1 and 50 ng/L; however 31 substances (mainly herbicides) had concentrations above 100 ng/L and 3 herbicides above 1000 ng/L. It has to be noted that the measured concentrations are average concentrations over two weeks in medium sized streams and that maximum

  2. Removal factor determination of some local smear papers for surface contamination smear test

    International Nuclear Information System (INIS)

    Suratman; Indriyotomo, D.; Aminjoyo, S.

    1996-01-01

    Removal factor determination of some local smear papers has been done, using dry smear test method. The aim of this research is to find removal values of local smear papers on some surfaces, to replace import smear papers. Smear test was done on the various surfaces i.e.: porcelain, formica, glass, stainless steel, steel and PVC, with the local smear papers I.e.: Padalarang, Diagonal, Concorde, Marga, Hard Cloth, and import smear paper. The artificial contaminant which used were I-131 and P-32. The removal factor values of Padalarang paper for surfaces: porcelain, formica, glass stainless steel, steel and PVC were: 24.5%, 20.0%, 27.0%, 6.8%, 4.9%, and 13.6% respectively. The removal factor values of Diagonal paper were:18.4%, 15.9%, 5.7%, 3.5%, and 9.1% respectively. The removal factor values of concord paper were: 18.5%, 20.3%, 23.1%, 6.6%, 3.8%, and 9.0% respectively. The removal factor values of Marga paper were: 16.7%, 13.5%, 21.1%, 4.2%, 4.1% and 8.1% respectively. The removal factor values of Hard Cloth were: 18.6%, 12.6%, 20.5%, 8.2%, and 10.1% respectively. The removal factor values of import smear paper were: 17.8%, 15.0%, 18.8%, 9.1%, 4.8%, and 14.4% respectively . Substitution alternative of import smear paper is Padalarang. (author)

  3. Surface and borehole electromagnetic imaging of conducting contaminant plumes. 1997 annual progress report

    International Nuclear Information System (INIS)

    Berryman, J.G.

    1997-01-01

    'Electromagnetic induction tomography is a promising new tool for imaging electrical conductivity variations in the earth. The EM source field is produced by induction coil (magnetic dipole) transmitters deployed at the surface or in boreholes. Vertical and horizontal component magnetic field detectors are deployed in other boreholes or on the surface. Sources and receivers are typically deployed in a configuration surrounding the region of interest. The goal of this procedure is to image electrical conductivity variations in the earth, much as x-ray tomography is used to image density variations through cross-sections of the body. Although such EM field techniques have been developed and applied, the algorithms for inverting the magnetic data to produce the desired images of electrical conductivity have not kept pace. One of the main reasons for the lag in the algorithm development has been the fact that the magnetic induction problem is inherently three dimensional: other imaging methods such as x-ray and seismic can make use of two-dimensional approximations that are not too far from reality, but the author does not have this luxury in EM induction tomography. In addition, previous field experiments were conducted at controlled test sites that typically do not have much external noise or extensive surface clutter problems often associated with environmental sites. To use the same field techniques in environments more typical of cleanup sites requires a new set of data processing tools to remove the effects of both noise and clutter. The goal of this project is to join theory and experiment to produce enhanced images of electrically conducting fluids underground, allowing better localization of contaminants and improved planning strategies for the subsequent remediation efforts. After explaining the physical context in more detail, this report will summarize the progress made in the first year of this project: (1) on code development and (2) on field tests of

  4. Listeria monocytogenes contamination of the environment and surfaces of the equipment in the meat processing facilities in republic of Macedonia

    OpenAIRE

    Dean Jankuloski; Pavle Sekulovski; Risto Prodanov; Zehra Hajrulai Musliu; Biljana Stojanovska Dimzovska

    2007-01-01

    Listeria monocytogenes contamination of the environment and surfaces of the equipment was examined in seven meat processing facilities. Up to date prevalence of this foodborn pathogen in meat processing facilities facilities in Republic of Macedonia was unknown. Biofilms are composed from food spoilage microorganisms and food born pathogens. They are located on the surfaces of the equipment that come in contact with food and in facilities environment. Microorganisms in biofilm presenting micr...

  5. MECHANISTIC STUDIES OF SURFACE CATALYZED H2O2 DECOMPOSITION AND CONTAMINANT DEGRADATION IN THE PRESENCE OF SAND. (R823402)

    Science.gov (United States)

    This study examined the mechanism and kinetics of surface catalyzed hydrogen peroxide decomposition and degradation of contaminants in the presence of sand collected from an aquifer and a riverbed. Batch experiments were conducted using variable sand concentrations (0.2 to 1.0&nb...

  6. ''In-situ'' spectro-electrochemical studies of radionuclide-contaminated surface films on metals

    International Nuclear Information System (INIS)

    Melendres, C.A.; Mini, S.; Mansour, A.N.

    2000-01-01

    The incorporation of heavy metal ions and radioactive contaminants into hydrous oxide films has been investigated in order to provide fundamental knowledge that could lead to the technological development of cost-effective processes and techniques for the decontamination of storage tanks, piping systems, surfaces, etc., in DOE nuclear facilities. The formation of oxide/hydroxide films was simulated by electrodeposition onto a graphite substrate from solutions of the appropriate metal salt. Synchrotron X-ray Absorption Spectroscopy (XAS), supplemented by Laser Raman Spectroscopy (LRS), was used to determine the structure and composition of the host oxide film, as well as the impurity ion. Results have been obtained for the incorporation of Ce, Sr, Cr, Fe, and U into hydrous nickel oxide films. Ce and Sr oxides/hydroxides are co-precipitated with the nickel oxides in separate phase domains. Cr and Fe, on the other hand, are able to substitute into Ni lattice sites or intercalate in the interlamellar positions of the brucite structure of Ni(OH) 2 . U was found to co-deposit as a U(VI) hydroxide. The mode of incorporation of metal ions depends both on the size and charge of the metal ion. The structure of iron oxide (hydroxide) films prepared by both anodic and cathodic deposition has also been extensively studied. The structure of Fe(OH) 2 was determined to be similar to that of α-Ni(OH) 2 . Anodic deposition from solutions containing Fe 2+ results in a film with a structure similar to γ-FeOOH. From the knowledge gained from the present studies, principles and methods for decontamination have become apparent. Contaminants sorbed on oxide surfaces or co-precipitated may be removed by acid wash and selective dissolution or complexation. Ions incorporated into lattice sites and interlamellar layers will require more drastic cleaning procedures. Electropolishing and the use of an electrochemical brush are among concepts that should be considered seriously for the latter

  7. EXPERIMENTAL COMPARISON OF THE AEROSOL METHOD OF DISINFECTION OF AIR AND SURFACES CONTAMINATED BY M. TUBERCULOSIS

    Directory of Open Access Journals (Sweden)

    V. V. Kuzin

    2018-01-01

    instead of disinfectant for control tests treating the tests objects contaminated in the same manner.Results. The good disinfection properties of Green Dez aerosol were proved during the simulation of M. tuberculosis, H37Rv strain, disinfection on the surfaces and in the air.The efficiency analysis of the aerosol method of disinfection proved the reduction of disinfectant consumption by 4-5 times versus wiping and irrigation, due to this the aerosol treatment can be regarded as a safer and more environmentally friendly method.The finely dispersed disinfectant aerosol, produced by MNC, effectively decontaminated the whole space, including the remote and hard-to-reach places. Full automation of disinfection implies no human presence providing high safety of disinfection. 

  8. Levels of major and trace elements, including rare earth elements, and ²³⁸U in Croatian tap waters.

    Science.gov (United States)

    Fiket, Željka; Rožmarić, Martina; Krmpotić, Matea; Benedik, Ljudmila

    2015-05-01

    Concentrations of 46 elements, including major, trace, and rare earth elements, and (238)U in Croatian tap waters were investigated. Selected sampling locations include tap waters from various hydrogeological regions, i.e., different types of aquifers, providing insight into the range of concentrations of studied elements and (238)U activity concentrations in Croatian tap waters. Obtained concentrations were compared with the Croatian maximum contaminant levels for trace elements in water intended for human consumption, as well as WHO and EPA drinking water standards. Concentrations in all analyzed tap waters were found in accordance with Croatian regulations, except tap water from Šibenik in which manganese in concentration above maximum permissible concentration (MPC) was measured. Furthermore, in tap water from Osijek, levels of arsenic exceeded the WHO guidelines and EPA regulations. In general, investigated tap waters were found to vary considerably in concentrations of studied elements, including (238)U activity concentrations. Causes of variability were further explored using statistical methods. Composition of studied tap waters was found to be predominately influenced by hydrogeological characteristics of the aquifer, at regional and local level, the existing redox conditions, and the household plumbing system. Rare earth element data, including abundances and fractionation patterns, complemented the characterization and facilitated the interpretation of factors affecting the composition of the analyzed tap waters.

  9. Influence of temporary cement contamination on the surface free energy and dentine bond strength of self-adhesive cements.

    Science.gov (United States)

    Takimoto, Masayuki; Ishii, Ryo; Iino, Masayoshi; Shimizu, Yusuke; Tsujimoto, Akimasa; Takamizawa, Toshiki; Ando, Susumu; Miyazaki, Masashi

    2012-02-01

    The surface free energy and dentine bond strength of self-adhesive cements were examined after the removal of temporary cements. The labial dentine surfaces of bovine mandibular incisors were wet ground with #600-grit SiC paper. Acrylic resin blocks were luted to the prepared dentine surfaces using HY Bond Temporary Cement Hard (HY), IP Temp Cement (IP), Fuji TEMP (FT) or Freegenol Temporary Cement (TC), and stored for 1 week. After removal of the temporary cements with an ultrasonic tip, the contact angle values of five specimens per test group were determined for the three test liquids, and the surface-energy parameters of the dentine surfaces were calculated. The dentine bond strengths of the self-adhesive cements were measured after removal of the temporary cements in a shear mode at a crosshead speed of 1.0mm/min. The data were subjected to one-way analysis of variance (ANOVA) followed by Tukey's HSD test. For all surfaces, the value of the estimated surface tension component γ(S)(d) (dispersion) was relatively constant at 41.7-43.3 mJm(-2). After removal of the temporary cements, the value of the γ(S)(h) (hydrogen-bonding) component decreased, particularly with FT and TC. The dentine bond strength of the self-adhesive cements was significantly higher for those without temporary cement contamination (8.2-10.6 MPa) than for those with temporary cement contamination (4.3-7.1 MPa). The γ(S) values decreased due to the decrease of γ(S)(h) values for the temporary cement-contaminated dentine. Contamination with temporary cements led to lower dentine bond strength. The presence of temporary cement interferes with the bonding performance of self-adhesive cements to dentine. Care should be taken in the methods of removal of temporary cement when using self-adhesive cements. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Thermodynamic and structural studies of mixed monolayers: Mutual mixing of DPPC and DPPG with DoTAP at the air-water interface

    International Nuclear Information System (INIS)

    Panda, Amiya Kumar; Vasilev, Krasimir; Orgeig, Sandra; Prestidge, Clive A.

    2010-01-01

    Phospholipid monomolecular films at the air-water interface are useful model membranes to understand miscibility among various components. Surface pressure (π)-area (A) isotherms of pure and mixed monolayers of dioleoyltrimethylammonium propane (DoTAP)-dipalmitoylphosphatidylcholine (DPPC) and DoTAP-dipalmitoyphosphatidylglycerol (DPPG) were constructed using a surface balance. DPPC and DPPG produced isotherms as expected and reported earlier. DoTAP, an unsaturated lipid, demonstrated a continuous π-A isotherm. Associative interactions were identified in DPPC-DoTAP mixtures compared to the pure components, while DPPG-DoTAP mixtures showed repulsive interaction up to an equimolar ratio. Compression moduli of the monolayers revealed that DPPC-DoTAP mixtures had increasing stability with increasing surface pressure, but addition of DoTAP to DPPG showed instability at low and intermediate concentrations. In both cases increased stability was returned at higher X DoTAP values and surface pressures. Lipid monolayer film thickness values, determined on a gold coated glass substrate by surface plasmon resonance spectroscopy (SPR), indicated a systematic change in height profile for DPPC-DoTAP mixtures with increasing X DoTAP . However, DPPG-DoTAP mixed monolayer systems demonstrated a biphasic response. The SPR data were in excellent agreement with our interpretation of the structure of solid supported lipid monolayers.

  11. Thermodynamic and structural studies of mixed monolayers: Mutual mixing of DPPC and DPPG with DoTAP at the air-water interface

    Energy Technology Data Exchange (ETDEWEB)

    Panda, Amiya Kumar, E-mail: akpanda1@yahoo.com [Department of Chemistry, University of North Bengal, Darjeeling-734 013, West Bengal (India); Vasilev, Krasimir [Mawson Institute for Advanced Manufacturing, Mawson Lakes, University of South Australia, SA-5095 (Australia); Orgeig, Sandra [Sansom Institute for Health Research and School of Pharmacy and Medical Sciences, University of South Australia, Adelaide, SA 5000 (Australia); Prestidge, Clive A. [Ian Wark Research Institute, University of South Australia, Mawson Lakes, SA 5095 (Australia)

    2010-05-10

    Phospholipid monomolecular films at the air-water interface are useful model membranes to understand miscibility among various components. Surface pressure ({pi})-area (A) isotherms of pure and mixed monolayers of dioleoyltrimethylammonium propane (DoTAP)-dipalmitoylphosphatidylcholine (DPPC) and DoTAP-dipalmitoyphosphatidylglycerol (DPPG) were constructed using a surface balance. DPPC and DPPG produced isotherms as expected and reported earlier. DoTAP, an unsaturated lipid, demonstrated a continuous {pi}-A isotherm. Associative interactions were identified in DPPC-DoTAP mixtures compared to the pure components, while DPPG-DoTAP mixtures showed repulsive interaction up to an equimolar ratio. Compression moduli of the monolayers revealed that DPPC-DoTAP mixtures had increasing stability with increasing surface pressure, but addition of DoTAP to DPPG showed instability at low and intermediate concentrations. In both cases increased stability was returned at higher X{sub DoTAP} values and surface pressures. Lipid monolayer film thickness values, determined on a gold coated glass substrate by surface plasmon resonance spectroscopy (SPR), indicated a systematic change in height profile for DPPC-DoTAP mixtures with increasing X{sub DoTAP}. However, DPPG-DoTAP mixed monolayer systems demonstrated a biphasic response. The SPR data were in excellent agreement with our interpretation of the structure of solid supported lipid monolayers.

  12. Chemical disinfection of non-porous inanimate surfaces experimentally contaminated with four human pathogenic viruses.

    Science.gov (United States)

    Sattar, S A; Springthorpe, V S; Karim, Y; Loro, P

    1989-06-01

    The chemical disinfection of virus-contaminated non-porous inanimate surfaces was investigated using coxsackievirus B3, adenovirus type 5, parainfluenza virus type 3 and coronavirus 229E as representatives of important nosocomial viral pathogens. A 10 microliter amount of the test virus, suspended in either faeces or mucin, was placed onto each stainless steel disk (about 1 cm in diameter) and the inoculum allowed to dry for 1 h under ambient conditions. Sixteen disinfectant formulations were selected for this study based on the findings of an earlier investigation with a human rotavirus. After 1 min exposure to 20 microliters of the disinfectant, the virus from the disks was immediately eluted into tryptose phosphate broth and plaque assayed. Using an efficacy criterion of a 3 log10 or greater reduction in virus infectivity titre and irrespective of the virus suspending medium, only the following five disinfectants proved to be effective against all the four viruses tested: (1) 2% glutaraldehyde normally used as an instrument soak, (2) a strongly alkaline mixture of 0.5% sodium o-benzyl-p-chlorophenate and 0.6% sodium lauryl sulphate, generally used as a domestic disinfectant cleaner for hard surfaces, (3) a 0.04% solution of a quaternary ammonium compound containing 7% hydrochloric acid, which is the basis of many toilet bowl cleaners, (4) chloramine T at a minimum free chlorine level of 3000 p.p.m. and (5) sodium hypochlorite at a minimum free chlorine concentration of 5000 p.p.m. Of those chemicals suitable for use as topical antiseptics, 70% ethanol alone or products containing at least 70% ethanol were ineffective only against coxsackievirus B3. These results emphasize the care needed in selecting chemical disinfectants for routine use in infection control.

  13. Cuban-Brazilian comparison of the calibration procedures for surface contamination monitors

    International Nuclear Information System (INIS)

    Salas, Gonzalo W.; Garcia, Jose A.T.; Ramos, Manoel M.O.

    2007-01-01

    The calibration laboratory of the CPHR, Centro de Proteccion e Higiene de las Radiaciones, is the only laboratory that performs calibrations of radiation protection instruments in Cuba. Recently they started a cooperation project with IAEA, code number CUB3002-01 with the task title 'Assuring and Demonstrating the safety of radioactive Waste Management'. Within the frame of this project they have a compromise to implement the calibration service for surface contamination monitors, for which they received instruments and sources. In 2006 the Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI) from the Instituto de Radioprotecao e Dosimetria, IRD/CNEN, was invited to perform a mission to CPHR in order to evaluate the level of implementation of the service trough the insertion of the service in the Quality Assurance System of their laboratory, and perform a comparison exercise to test the calibration method implemented. The results were evaluated by the methodology recommended in the ISO/IEC 43-1 standard. These results show that all values from both laboratories are comparable for most radionuclides except for Cl-36. The preliminary investigation about this situation is presented in the paper. (author)

  14. Chemical and toxicologic assessment of organic contaminants in surface water using passive samplers

    Science.gov (United States)

    Alvarez, D.A.; Cranor, W.L.; Perkins, S.D.; Clark, R.C.; Smith, S.B.

    2008-01-01

    Passive sampling methodologies were used to conduct a chemical and toxicologic assessment of organic contaminants in the surface waters of three geographically distinct agricultural watersheds. A selection of current-use agrochemicals and persistent organic pollutants, including polycyclic aromatic hydrocarbons, polychlorinated biphenyls, and organochlorine pesticides, were targeted using the polar organic chemical integrative sampler (POCIS) and the semipermeable membrane device passive samplers. In addition to the chemical analysis, the Microtox assay for acute toxicity and the yeast estrogen screen (YES) were conducted as potential assessment tools in combination with the passive samplers. During the spring of 2004, the passive samplers were deployed for 29 to 65 d at Leary Weber Ditch, IN; Morgan Creek, MD; and DR2 Drain, WA. Chemical analysis of the sampler extracts identified the agrochemicals predominantly used in those areas, including atrazine, simazine, acetochlor, and metolachlor. Other chemicals identified included deethylatrazine and deisopropylatrazine, trifluralin, fluoranthene, pyrene, cis- and trans-nonachlor, and pentachloroanisole. Screening using Microtox resulted in no acutely toxic samples. POCIS samples screened by the YES assay failed to elicit a positive estrogenic response. Copyright ?? 2008 by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America. All rights reserved.

  15. Contamination assessment of heavy metal in surface sediments of the Wuding River, northern China

    International Nuclear Information System (INIS)

    Longjiang, M.; Qiang, F.; Duowen, M.; Ke, H.; Jinghong, Y.

    2011-01-01

    The heavy metal contents and the contamination levels of the surface sediments of the Wuding River, northern China, were investigated. Heavy metal concentration ranged in μg g -1 : 50.15 - 71.91 for Cr, 408.1 - 442.9 for Mn, 20.11 - 43.59 for Ni, 17.51 - 20.1 for Cu, 68.32 - 89.57 for Zn, 0.2 - 0.38 for Cd and 15.08 - 16.14 for Pb in the Wuding River sediments. The enrichment factor (EF) and the geo-accumulation index (Igeo) demonstrated that the sediments of the Wuding River had been polluted by Cd, Cr and Ni, which mainly originated from anthropogenic sources, whereas the sediments had not been polluted by Zn, Pb, Cu and Mn, which were derived from the crust. In addition, the assessment results of EF and Igeo suggested that the sediments of the Wuding River was 'moderately' polluted by Cd and 'unpolluted to moderately' polluted by Cr and Ni. The elevated urban sewage discharges and agriculture fertilizers usage in river basin are the anthropogenic sources of these heavy metals in river. (author)

  16. Effect of electrocardiographic contamination on surface electromyography assessment of back muscles.

    Science.gov (United States)

    Hu, Yong; Mak, Joseph N F; Luk, Keith D K

    2009-02-01

    The purpose of this study was to demonstrate the relative effect of electrocardiography (ECG) on back muscle surface electromyography (SEMG) parameters and their corresponding sensitivity in low back pain (LBP) assessment. Back muscle SEMG activities were recorded from 17 healthy subjects and 18 chronic LBP patients under static postures (straight sitting and upright standing), and dynamic action (flexion-extension). ECG cancellation based on independent component analysis (ICA) method was performed. Root mean square (RMS) and median frequency (MF) of raw and denoised SEMG data were computed respectively. Multiple comparisons were then performed. A consistent trend of change (increased MF and decreased RMS) followed ECG removal was noticed. In particular, in SEMG measurements under static postures, a significant decrease in RMS (pcorruption by ECG artifacts on SEMG measurements was found to be more serious and prominent in static postures than that in dynamic action. After ECG removal, significant improvements in the ability of SEMG to discriminate LBP patients from healthy subjects were seen in RMS amplitude recorded while standing (peffect of ECG contamination on back muscles SEMG parameters and LBP assessment.

  17. Strippable core-shell polymer emulsion for decontamination of radioactive surface contamination

    International Nuclear Information System (INIS)

    Hwang, Ho-Sang; Seo, Bum-Kyoung; Lee, Kune-Woo

    2011-01-01

    In this study, the core-shell composite polymer for decontamination from the surface contamination was synthesized by the method of emulsion polymerization and blends of polymers. The strippable polymer emulsion is composed of the poly(styrene-ethyl acrylate) [poly(St-EA)] composite polymer, poly(vinyl alcohol) (PVA) and polyvinylpyrrolidone (PVP). The morphology of the poly(St-EA) composite emulsion particle was core-shell structure, with polystyrene (PS) as the core and poly(ethyl acrylate) (PEA) as the shell. Core-shell polymers of styrene (St)/ethyl acrylate (EA) pair were prepared by sequential emulsion polymerization in the presence of sodium dodecyl sulfate (SDS) as an emulsifier using ammonium persulfate (APS) as an initiator. Related tests and analysis confirmed the success in synthesis of composite polymer. The products are characterized by FT-IR spectroscopy, TGA that were used, respectively, to show the structure, the thermal stability of the prepared polymer. Two-phase particles with a core-shell structure were obtained in experiments where the estimated glass transition temperature and the morphologies of emulsion particles. Decontamination factors of the strippable polymeric emulsion were evaluated with the polymer blend contents. (author)

  18. SCO shipments from Rocky Flats - Experience and current practice [Surface Contaminated Object

    International Nuclear Information System (INIS)

    Bracken, Gary; Morris, Robert L.

    2001-01-01

    Decommissioning activities at Rocky Flats Environmental Technology Site (RFETS) are expected to generate approximately 251,000 cubic meters of low-level radioactive waste. Almost half of this will be characterized and shipped as the Department of Transportation ''Surface Contaminated Object'' (SCO) shipping class. In the 2 years since an SCO characterization method was implemented, almost 11,000 of the 18,000 cubic meters of low-level waste were SCO. RFETS experience to-date using an SCO waste characterization method has shown significant time and cost savings, reduced errors, and enhanced employee safety. SCO waste is characterized prior to packaging, near the point of generation, by any of the site's 300 Radiological Control Technicians using inexpensive radiological control survey instruments. This reduces on-site waste container moves and eliminates radiometric analysis at centrally located drum or crate counters. Containers too large for crate counters can also be characterized. Current instrumentation is not adequate to take full advantage of the SCO regulations. Future improvements in the SCO characterization and shipping process are focused on use of larger and/or reusable containers, extended-range instruments, and additional statistical methods, so that the full extent of the SCO regulations can be used

  19. Tapping mode atomic force microscopy in liquid

    NARCIS (Netherlands)

    Putman, Constant A.J.; Putman, C.A.J.; van der Werf, Kees; de Grooth, B.G.; van Hulst, N.F.; Greve, Jan

    1994-01-01

    We show that standard silicon nitride cantilevers can be used for tapping mode atomic force microscopy (AFM) in air, provided that the energy of the oscillating cantilever is sufficiently high to overcome the adhesion of the water layer. The same cantilevers are successfully used for tapping mode

  20. Military Transition Assistance Program (TAP): An Overview

    Science.gov (United States)

    2017-03-15

    in the development, management oversight, and strategic planning of TAP. TAP Counseling Requirements Over time, Congress has increased the...training, and placement services provided under qualified job training programs of the DOL* Veterans small business ownership and entrepreneurship ...Accessing Higher Education (DOD) Career Technical Training (VA) Entrepreneurship (SBA) Capstone Verifies that servicemembers have met Career

  1. Stochastic Radiative Transfer Model for Contaminated Rough Surfaces: A Framework for Detection System Design

    Science.gov (United States)

    2013-11-01

    example for the detection of a potassium chlorate contaminated “car” with a CO2 tunable laser system. 15. SUBJECT TERMS Radiative transfer...detector m-out-of-n detector Potassium chlorate Probability theory System performance Probability of detection and false alarm iii...for the detection of a potassium chlorate contaminated “car” with a CO2 tunable laser system. Subject Terms Radiative transfer, contaminated

  2. HYDROLASING OF CONTAMINATED UNDERWATER BASIN SURFACES AT THE HANFORD K AREA

    International Nuclear Information System (INIS)

    CHRONISTER, G.B.

    2005-01-01

    This paper discusses selecting and implementing hydrolasing technology to reduce radioactive contamination in preparing to dispose of the K Basins; two highly contaminated concrete basins at the Hanford Site. A large collection of spent nuclear fuel stored for many years underwater at the K Basins has been removed to stable, dry, safe storage. Remediation activities have begun for the remaining highly contaminated water. sludge, and concrete basin structures. Hydrolasing will be used to decontaminate and prepare the basin structures for disposal

  3. Contamination of surface and underground waters owing to the disaster of the Sasa mine tailing pond

    OpenAIRE

    Mircovski, Vojo; Spasovski, Orce

    2003-01-01

    The uncontrolled run off of flotation waste from the Sasa Mine causes contamination of the flows of the Rivers Kamenicka and Bregalnica as well as the water of Kalimanci Lake and further afield. Boundary, fracture and karst type of aquifers formed depending on the structural type of porosity along the marginal parts of the terrain. The aquifers are recharged mostly by the above mentioned rivers that results in contamination of their waters. Contamination of underground waters is particularly ...

  4. Do contaminants originating from state-of-the-art treated wastewater impact the ecological quality of surface waters?

    Science.gov (United States)

    Stalter, Daniel; Magdeburg, Axel; Quednow, Kristin; Botzat, Alexandra; Oehlmann, Jörg

    2013-01-01

    Since the 1980s, advances in wastewater treatment technology have led to considerably improved surface water quality in the urban areas of many high income countries. However, trace concentrations of organic wastewater-associated contaminants may still pose a key environmental hazard impairing the ecological quality of surface waters. To identify key impact factors, we analyzed the effects of a wide range of anthropogenic and environmental variables on the aquatic macroinvertebrate community. We assessed ecological water quality at 26 sampling sites in four urban German lowland river systems with a 0-100% load of state-of-the-art biological activated sludge treated wastewater. The chemical analysis suite comprised 12 organic contaminants (five phosphor organic flame retardants, two musk fragrances, bisphenol A, nonylphenol, octylphenol, diethyltoluamide, terbutryn), 16 polycyclic aromatic hydrocarbons, and 12 heavy metals. Non-metric multidimensional scaling identified organic contaminants that are mainly wastewater-associated (i.e., phosphor organic flame retardants, musk fragrances, and diethyltoluamide) as a major impact variable on macroinvertebrate species composition. The structural degradation of streams was also identified as a significant factor. Multiple linear regression models revealed a significant impact of organic contaminants on invertebrate populations, in particular on Ephemeroptera, Plecoptera, and Trichoptera species. Spearman rank correlation analyses confirmed wastewater-associated organic contaminants as the most significant variable negatively impacting the biodiversity of sensitive macroinvertebrate species. In addition to increased aquatic pollution with organic contaminants, a greater wastewater fraction was accompanied by a slight decrease in oxygen concentration and an increase in salinity. This study highlights the importance of reducing the wastewater-associated impact on surface waters. For aquatic ecosystems in urban areas this

  5. Do Contaminants Originating from State-of-the-Art Treated Wastewater Impact the Ecological Quality of Surface Waters?

    Science.gov (United States)

    Stalter, Daniel; Magdeburg, Axel; Quednow, Kristin; Botzat, Alexandra; Oehlmann, Jörg

    2013-01-01

    Since the 1980s, advances in wastewater treatment technology have led to considerably improved surface water quality in the urban areas of many high income countries. However, trace concentrations of organic wastewater-associated contaminants may still pose a key environmental hazard impairing the ecological quality of surface waters. To identify key impact factors, we analyzed the effects of a wide range of anthropogenic and environmental variables on the aquatic macroinvertebrate community. We assessed ecological water quality at 26 sampling sites in four urban German lowland river systems with a 0–100% load of state-of-the-art biological activated sludge treated wastewater. The chemical analysis suite comprised 12 organic contaminants (five phosphor organic flame retardants, two musk fragrances, bisphenol A, nonylphenol, octylphenol, diethyltoluamide, terbutryn), 16 polycyclic aromatic hydrocarbons, and 12 heavy metals. Non-metric multidimensional scaling identified organic contaminants that are mainly wastewater-associated (i.e., phosphor organic flame retardants, musk fragrances, and diethyltoluamide) as a major impact variable on macroinvertebrate species composition. The structural degradation of streams was also identified as a significant factor. Multiple linear regression models revealed a significant impact of organic contaminants on invertebrate populations, in particular on Ephemeroptera, Plecoptera, and Trichoptera species. Spearman rank correlation analyses confirmed wastewater-associated organic contaminants as the most significant variable negatively impacting the biodiversity of sensitive macroinvertebrate species. In addition to increased aquatic pollution with organic contaminants, a greater wastewater fraction was accompanied by a slight decrease in oxygen concentration and an increase in salinity. This study highlights the importance of reducing the wastewater-associated impact on surface waters. For aquatic ecosystems in urban areas this

  6. Do contaminants originating from state-of-the-art treated wastewater impact the ecological quality of surface waters?

    Directory of Open Access Journals (Sweden)

    Daniel Stalter

    Full Text Available Since the 1980s, advances in wastewater treatment technology have led to considerably improved surface water quality in the urban areas of many high income countries. However, trace concentrations of organic wastewater-associated contaminants may still pose a key environmental hazard impairing the ecological quality of surface waters. To identify key impact factors, we analyzed the effects of a wide range of anthropogenic and environmental variables on the aquatic macroinvertebrate community. We assessed ecological water quality at 26 sampling sites in four urban German lowland river systems with a 0-100% load of state-of-the-art biological activated sludge treated wastewater. The chemical analysis suite comprised 12 organic contaminants (five phosphor organic flame retardants, two musk fragrances, bisphenol A, nonylphenol, octylphenol, diethyltoluamide, terbutryn, 16 polycyclic aromatic hydrocarbons, and 12 heavy metals. Non-metric multidimensional scaling identified organic contaminants that are mainly wastewater-associated (i.e., phosphor organic flame retardants, musk fragrances, and diethyltoluamide as a major impact variable on macroinvertebrate species composition. The structural degradation of streams was also identified as a significant factor. Multiple linear regression models revealed a significant impact of organic contaminants on invertebrate populations, in particular on Ephemeroptera, Plecoptera, and Trichoptera species. Spearman rank correlation analyses confirmed wastewater-associated organic contaminants as the most significant variable negatively impacting the biodiversity of sensitive macroinvertebrate species. In addition to increased aquatic pollution with organic contaminants, a greater wastewater fraction was accompanied by a slight decrease in oxygen concentration and an increase in salinity. This study highlights the importance of reducing the wastewater-associated impact on surface waters. For aquatic ecosystems in

  7. Electronic tap-changer for distribution transformers

    Energy Technology Data Exchange (ETDEWEB)

    Faiz, Jawad [Tehran Univ. (Iran, Islamic Republic of). Univ. College of Engineering; Siahkolah, Behzad [Kavandish Company, Tehran (Iran, Islamic Republic of)

    2011-07-01

    This reference collects all relevant aspects electronic tap-changer and presents them in a comprehensive and orderly manner. It explains logically and systematically the design and optimization of a full electronic tap-changer for distribution transformers. The book provides a fully new insight to all possible structures of power section design and categorizes them comprehensively, including cost factors of the design. In the control section design, the authors review mechanical tap-changer control systems and they present the modeling of a full electronic tap-changer as well as a closed-loop control of the full-electronic tap-changer. The book is written for electrical engineers in industry and academia but should be useful also to postgraduate students of electrical engineering. (orig.)

  8. Hygienic safety of reusable tap water filters (Germlyser® with an operating time of 4 or 8 weeks in a haematological oncology transplantation unit

    Directory of Open Access Journals (Sweden)

    Rochow Markus

    2007-05-01

    Full Text Available Abstract Background Microbial safe tap water is crucial for the safety of immunosuppressed patients. Methods To evaluate the suitability of new, reusable point-of-use filters (Germlyser®, Aquafree GmbH, Hamburg, Germany, three variations of a reusable filter with the same filter principle but with different outlets (with and without silver and inner surface coating of the filter encasements (with and without nano-crystalline silver were tested. The filter efficacy was monitored over 1, 4 and 8 weeks operating time in a haematological oncology transplantation unit equipped with 18 water outlets (12 taps, 6 showers. Results The filtered water fulfilled the requirements of absence of pathogens over time. From 348 samples, 8 samples (2.3% exceeded 100 cfu/ml (no sample ≥ 500 cfu/ml. As no reprocessed filter exhibited 100% filter efficacy in the final quality control after each reprocessing, these contaminations could be explained by retrograde contamination during use. Conclusion As a consequence of the study, the manufacturer recommends changing filters after 4 weeks in high risk areas and after 8 weeks in moderate infectious risk areas, together with routine weekly alcohol-based surface disinfection and additionally in case of visible contamination. The filter efficacy of the 3 filters types did not differ significantly regarding total bacterial counts. Manual reprocessing proved to be insufficient. Using a validated reprocessing in a washer/disinfector with alkaline, acid treatment and thermic disinfection, the filters were effectively reprocessable and now provide tap water meeting the German drinking water regulations as well as the WHO guidelines, including absence of pathogens.

  9. Freely Chosen Index Finger Tapping Frequency Is Increased in Repeated Bouts of Tapping.

    Science.gov (United States)

    Hansen, Ernst Albin; Ebbesen, Brian Duborg; Dalsgaard, Ane; Mora-Jensen, Mark Holten; Rasmussen, Jakob

    2015-01-01

    Healthy individuals (n = 40) performed index finger tapping at freely chosen frequency during repeated bouts and before and after near-maximal muscle action consisting of 3 intense flexions of the index finger metacarpal phalangeal joint. One experiment showed, unexpectedly, that a bout of tapping increased the tapping frequency in the subsequent bout. Thus, a cumulating increase of 8.2 ± 5.4% (p tapping frequency was still increased in consecutive bouts when rest periods were extended to 20 min. Besides, near-maximal muscle activation, followed by 5 min rest, did not affect the tapping frequency. In conclusion, freely chosen tapping frequency was increased in repeated bouts of tapping, which were separated by 10-20 min rest periods. The observed phenomenon is suggested to be termed repeated bout rate enhancement.

  10. A quantitative analysis of cross-contamination of Salmonella and Campylobacter spp. via domestic kitchen surfaces

    NARCIS (Netherlands)

    Kusumaningrum, H.D.; Asselt, van E.D.; Beumer, R.R.; Zwietering, M.H.

    2004-01-01

    Epidemiological data indicate that cross-contamination during food preparation in the home contributes noticeably to the occurrence of foodborne diseases. To help prevent such occurrences, the inclusion of a cross-contamination model in exposure assessments would aid in the development and

  11. Control of the surface radioactive contamination in the field of biological research

    International Nuclear Information System (INIS)

    Calvo, S.; Encina, A. de la; Gaspar, J.; Macias, M. T.; Sanchez, A.; Usera, F.

    2012-01-01

    The manipulation of unsealed sources in biomedical research involves significant risk of radioactive contamination. the aim of this study has been to analyze the radioactive contamination occurring in the field of biomedical research, assessing its magnitude, identifying the equipment that can be contaminated with higher probability and monitoring the evolution of the contaminations production taking into account the radioisotopes and the activities uses, and the radiation protection control applied. The data used for this study correspond to a very lengthy period of time and it have been collected in the radioactive facility, of the Centro Nacional de Biotecnologia (CSIC), a very large biological research centre that can be used perfectly as a reference for this area. The results obtained show a gradual and significant decrease in the incidence of the radioactive contamination. This is due to the optimization of radiation protection standards applied and the implementation or a systematic operational radiation protection program. (Author) 13 refs.

  12. Klebsiella sp. FIRD 2, a TBT-resistant bacterium isolated from contaminated surface sediment along Strait of Johor Malaysia.

    Science.gov (United States)

    Abubakar, Abdussamad; Mustafa, Muskhazli B; Johari, Wan Lutfi Wan; Zulkifli, Syaizwan Zahmir; Ismail, Ahmad; Mohamat-Yusuff, Ferdaus Binti

    2015-12-15

    A possible tributyltin (TBT)-degrading bacterium isolated from contaminated surface sediment was successfully identified as Klebsiella sp. FIRD 2. It was found to be the best isolate capable of resisting TBT at a concentration of 1000 μg L(-1). This was a concentration above the reported contaminated level at the sampling station, 790 μg L(-1). Further studies revealed that the isolate was Gram negative and resisted TBT concentrations of up to 1500 μg L(-1) in a Minimal Salt Broth without the addition of any carbon source within the first 48 h of incubation. It is expected that additional work could be conducted to check the degradation activity of this new isolate and possibly improve the degradation capacity in order to contribute to finding a safe and sustainable remediation solution of TBT contamination. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. HIGH PERFORMANCE TAPS FOR CUTTING THREADS IN DIFFICULT TO MACHINE MATERIALS

    Directory of Open Access Journals (Sweden)

    M. R. Akhmedova

    2016-01-01

    Full Text Available Objectives. This article explores in detail questions of instrument operation function of tapping internal threads in hard materials. The existing relationship between vibration system amplitude and tool durability is indicated; on this basis, it is determined that the best course for improving the durability performance is increasing vibratory resistance. Based on a critical analysis of existing designs with consideration of their flaws, the development of new technological designs of taps is tasked with ensuring stable operation when handling hard materials. Methods. It is noteworthy that one of the main vibration resistance improvement methods of the tool is to reduce the contact area of the tool with the work piece in the cutting zone. Methods are proposed for improving the vibration resistance of taps, considering the correlation adjustment of tap teeth in order to completely eliminate friction at the sides of the thread cutting surface and uneven implementation flute cutting steps. Results. The idea of increasing vibration resistance has seen the new development of vibration-proof tap designs, heralded as innovations due to the accuracy of thread cutting and durability achieved by reducing the thread contact area with the work piece in the cutting zone. Increased vibration resistance is achieved in the modified taps through high correction by means of thread side downgrading of the coarse tap cone by an additional angle of 30º. In another design, the stylus provided with uneven angular spacing. Test results of designed taps machined in corrosion-resistant 1Kh18N9T steel. A manifold increase in tool durability was achieved due to its high vibration resistance. Conclusions. The redesigned taps have a number of advantages, characterised by a high resistance when processing difficult materials and an insignificant increase in the complexity of their manufacture compared with standard taps. Therefore they can be recommended for large

  14. An analysis of the impact of native oxide, surface contamination and material density on total electron yield in the absence of surface charging effects

    Energy Technology Data Exchange (ETDEWEB)

    Iida, Susumu, E-mail: susumu.iida@toshiba.co.jp [EUVL Infrastructure Development Center, Inc., 16-1 Onogawa, Tsukuba-shi, Ibaraki-ken, 305-8569 (Japan); Ohya, Kaoru [Institute of Technology and Science, The University of Tokushima, 2-1 Minamijyousanjima-cho,Tokushima, 770-8506 (Japan); Hirano, Ryoichi; Watanabe, Hidehiro [EUVL Infrastructure Development Center, Inc., 16-1 Onogawa, Tsukuba-shi, Ibaraki-ken, 305-8569 (Japan)

    2016-10-30

    Highlights: • Total electron yields were assessed in the absence of any surface charging effect. • Experimental and simulation results showed a low native oxide energy barrier. • The yield enhancement effect of a native oxide layer was confirmed. • The yield enhancement effect of a thin surface contamination layer was confirmed. • Deviations in the material density from the theoretical values were evaluated. - Abstract: The effects of the presence of a native oxide film or surface contamination as well as variations in material density on the total electron yield (TEY) of Ru and B{sub 4}C were assessed in the absence of any surface charging effect. The experimental results were analyzed using semi-empirical Monte Carlo simulations and demonstrated that a native oxide film increased the TEY, and that this effect varied with film thickness. These phenomena were explained based on the effect of the backscattered electrons (BSEs) at the interface between Ru and RuO{sub 2}, as well as the lower potential barrier of RuO{sub 2}. Deviations in the material density from the theoretical values were attributed to the film deposition procedure based on fitting simulated TEY curves to experimental results. In the case of B{sub 4}C, the TEY was enhanced by the presence of a 0.8-nm-thick surface contamination film consisting of oxygenated hydrocarbons. The effect of the low potential barrier of the contamination film was found to be significant, as the density of the B{sub 4}C was much lower than that of the Ru. Comparing the simulation parameters generated in the present work with Joy’s database, it was found that the model and the input parameters used in the simulations were sufficiently accurate.

  15. On the Cutting Performance of Coated HSS Taps When Machining of Austenitic Steel

    Science.gov (United States)

    Sliwkova, Petra; Piska, Miroslav

    2014-12-01

    The paper deals with a quality of the PVD coated HSS taps when cutting the stainless austenitic chromiumnickel non-stabilized steel DIN 1.4301 (X5CrNi 18-10). The main attention is focused on the analysis of loading (cutting moment, specific energy) of the HSS taps by means of pieso-electrical dynamometer Kistler 9272 and the relation between the quality of duplex and triplex PVD coatings and their effects on the quality of machined thread surfaces and tool life of the taps. The results showed a safe and stabilized cutting with acceptable quality of threads for HSSE with the TiN+TiCN+DLC coating.

  16. The influence of surface contamination on the ion emission from nanosecond-pulsed laser ablation of Al and Cu

    Science.gov (United States)

    Ullah, S.; Dogar, A. H.; Qayyum, H.; Rehman, Z. U.; Qayyum, A.

    2018-04-01

    Ions emitted from planar Al and Cu targets irradiated with a 1064 nm pulsed laser were investigated with the help of a time-resolving Langmuir probe. It was found that the intensity of the ions emitted from a target area rapidly decreases with the increasing number of laser shots, and seems to reach saturation after about 10 laser shots. The saturated intensity of Al and Cu ions was approximately 0.1 and 0.3 times the intensity of the respective ions measured at the first laser shot, respectively. The higher target ion intensity for the first few shots is thought to be due to the enhanced ionization of target atoms by vacuum-ultraviolet radiations emitted from the thermally excited/ionized surface contaminants. The reduction of target ion intensity with an increasing number of laser shots thus indicates the removal of contaminants from the irradiated surface area. Laser-cleaned Al and Cu surfaces were then allowed to be recontaminated with residual vacuum gases and the ion intensity was measured at various time delays. The prolonged exposure of the cleaned target to vacuum residual gases completely restores the ion intensity. Regarding surface contaminants removal, laser shots of higher intensities were found to be more effective than a higher number of laser shots having lower intensities.

  17. Tapping a new energy source

    International Nuclear Information System (INIS)

    Thomas, W.

    1999-01-01

    The Sable Offshore Energy Project is one of Canada's largest construction projects which is bringing a new industry to Nova Scotia. A five-party consortium comprised of Mobil Oil Canada, Shell Canada, Imperial Oil, Nova Scotia Resources and Mosbacher, has formed an enterprise called Sable Offshore Energy Inc. The consortium plans to bring natural gas to markets in Canada and the United States before the end of 1999. The Santa Fe Galaxy II is one of the world's most modern marine all-weather drilling rigs that will soon begin the drilling of wells. Once in production, the project will produce half a billion cubic feet of natural gas daily from three production platforms that will tap three separate undersea natural gas fields. The gas will then be transported 200 km to shore near Goldboro, Nova Scotia, through an undersea pipeline. There, it will be treated to remove any remaining water and to separate liquid natural gas from the gas proper. The natural gas liquids will then be carried by an onshore pipeline to a new facility at Point Tupper where they will be processed into propane, butane and condensate. There will be enough gas to meet the potential demand in Nova Scotia and New Brunswick. Large urban centres such as Halifax and Saint John will be served by secondary lines that branch off the main pipeline, but developing smaller markets will take time because the necessary infrastructure does not yet exist. The project has already created thousands of jobs in the province. 5 figs

  18. Contamination by persistent toxic substances in surface sediment of urban rivers in Chaohu City, China.

    Science.gov (United States)

    Li, Feipeng; Zhang, Haiping; Meng, Xiangzhou; Chen, Ling; Yin, Daqiang

    2012-01-01

    The concentration and spatial distribution of persistent toxic substances (PTS) in the river sediment in Chaohu City, China were investigated. A total of nine surface sediments were collected and the selected PTS pollutants including six heavy metals and nineteen polybrominated diphenyl ethers (PBDEs) were analyzed. The mean heavy metal concentrations (in mg/kg, dry weight) ranged within 0.18-1.53 (Hg), 50.08-200.18 (Cu), 118.70-313.65 (Zn), 50.77-310.85 (Cr), 37.12-92.72 (Pb) and 13.29-197.24 (As), and Cu, Zn and As have been regarded as the main metal pollutants. The levels of PBDEs (1.2-12.1 ng/g) and BDE-209 (2.4-30.5 ng/g) were at the middle level of the global range. BDE-209 was the predominant congener (67.0%-85.7%), which agrees with the fact that technical deca-BDE mixtures are the dominant PBDE formulation in China. The relative high level of PTS pollutants in the western part of the city is probably owing to the intensive agricultural activities and lack of sewerage system there. The ecological risk assessment with the sediment quality guidelines (SOGs) indicates that the urban river sediments in the city have been heavily contaminated by heavy metals with probable ecotoxicological impacts on freshwater organisms and the main toxic pollutants are Hg and As. The results of current study imply that the city, and perhaps many other small cities in China as well, requires immediate pollution control measures with emphasis on not only conventional organic pollutants but also on PTS such as heavy metals and PBDEs.

  19. Surface contamination of spent fuel convoys - resumption of transport in France

    International Nuclear Information System (INIS)

    Pertuis, V.

    2000-01-01

    In France, 1998 was marked by the transport of spent fuel from EDF plants being suspended and then resumed. From the time the first inspections were carried out by the Nuclear Installations Safety Directorate (NISD), in charge of monitoring radioactive and fissile material for civil use since June 1997, surface contamination was found in a high percentage of packages and/or wagons containing spent fuel. The different expert appraisals showed that this had no consequences for the health of the public or of workers. Aiming at the resumption of transport, EDF and Cogema presented to the safety authority a plan of action including an increase in monitoring (number of points and cross-checking by SGS Qualitest), more widespread observance of good practices resulting from analyses by EDF and conclusions of its nuclear inspectorate, and an improvement in radiological cleanliness in the area where casks were loaded. During the inspections carried out at EDF plants, the NISD verified the application of this plan. Several observations were, nevertheless, made regarding maintenance of equipment, failure to apply procedures on a corporate level and the traceability of certain operations. The measures taken to sufficiently inform the public were applied. The NISD is continuing its monitoring actions to ensure that all EDF plants adopt best practices. However, the overall clean-up of EDF plants is a long-term operation. Finally, the NISD is continuing its monitoring of the different stages of spent fuel transport as well as other types of transport of radioactive materials associated with nuclear activities. (author)

  20. Lower extremity kinetics in tap dance.

    Science.gov (United States)

    Mayers, Lester; Bronner, Shaw; Agraharasamakulam, Sujani; Ojofeitimi, Sheyi

    2010-01-01

    Tap dance is a unique performing art utilizing the lower extremities as percussion instruments. In a previous study these authors reported decreased injury prevalence among tap dancers compared to other dance and sports participants. No biomechanical analyses of tap dance exist to explain this finding. The purpose of the current pilot study was to provide a preliminary overview of normative peak kinetic and kinematic data, based on the hypothesis that tap dance generates relatively low ground reaction forces and joint forces and moments. Six professional tap dancers performed four common tap dance sequences that produced data captured by the use of a force platform and a five-camera motion analysis system. The mean vertical ground reaction force for all sequences was found to be 2.06+/-0.55 BW. Mean peak sagittal, frontal, and transverse plane joint moments (hip, knee, and ankle) ranged from 0.07 to 2.62 N.m/kg. These small ground reaction forces and joint forces and moments support our hypothesis, and may explain the relatively low injury incidence in tap dancers. Nevertheless, the analysis is highly complex, and other factors remain to be studied and clarified.

  1. Tritium activity balance in hairless rats following skin-contact exposure to tritium-gas-contaminated stainless-steel surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Trivedi, A

    1994-06-01

    Studies using animals and human volunteers have demonstrated that the dosimetry for skin-contact exposure to contaminated metal surfaces differs from that for the intake of tritiated water or tritium gas. However, despite the availability of some information on the dosimetry for skin-contact with tritium-gas-contaminated metal surfaces, uncertainties in estimating skin doses remain, because of poor accounting for the applied tritium activity in the body (Eakins et al., 1975; Trivedi, 1993). Experiments on hairless rats were performed to account for the tritium activity applied onto the skin. Hairless rats were contaminated through skin-contact exposure to tritium-gas-contaminated stainless-steel planchets. The activity in the first smear was about 35% of the total removable activity (measured by summing ten consecutive swipes). The amount of tritium applied onto the skin can be approximated by estimating the tritium activity in the first smear removed form the contaminated surfaces. 87 {+-} 9% of the transferred tritium was retained in the exposed skin 30 min post-exposure. 30 min post exposure, the unexposed skin and the carcass retained 8 {+-} 6% and 3 {+-} 2% of the total applied tritium activity, respectively. The percentage of tritium evolved from the body or breathed out was estimated to be 2 {+-} 1% of the total applied activity 30 min post-exposure. It is recommended that to evaluate accurately the amount of tritium transferred to the skin, alternative measurement approaches are required that can directly account for the transferred activity onto the skin. 15 refs., 13 tabs., 7 figs.

  2. Radiation contamination monitors

    International Nuclear Information System (INIS)

    Kato, Tsutomu; Iba, Hiroshi; Sato, Hiroshi

    1999-01-01

    To make sure of no contamination on people, used articles and working uniforms coming out of the radiation controlled area, nuclear power plants are equipped with radioactive contamination monitors. This paper outlines the basic specifications and advantages of our personnel surface contamination monitors to inspect whole-body surface contamination of people coming out, article surface contamination monitors to inspect the surface and inside contamination of used articles brought out, laundry monitors to inspect surface contamination of working uniforms used in the area before and after a wash, and whole-body counters to inspect and measure the internal contamination of a person out of the area. (author)

  3. Bacterial contamination on touch surfaces in the public transport system and in public areas of a hospital in London.

    Science.gov (United States)

    Otter, J A; French, G L

    2009-12-01

    To investigate bacterial contamination on hand-touch surfaces in the public transport system and in public areas of a hospital in central London. Dipslides were used to sample 118 hand-touch surfaces in buses, trains, stations, hotels and public areas of a hospital in central London. Total aerobic counts were determined, and Staphylococcus aureus isolates were identified and characterized. Bacteria were cultured from 112 (95%) of sites at a median concentration of 12 CFU cm(-2). Methicillin-susceptible Staph. aureus (MSSA) was cultured from nine (8%) of sites; no sites grew methicillin-resistant Staph. aureus (MRSA). Hand-touch sites in London are frequently contaminated with bacteria and can harbour MSSA, but none of the sites tested were contaminated with MRSA. Hand-touch sites can become contaminated with staphylococci and may be fomites for the transmission of bacteria between humans. Such sites could provide a reservoir for community-associated MRSA (CA-MRSA) in high prevalence areas but were not present in London, a geographical area with a low incidence of CA-MRSA.

  4. OPERATIONAL LIMITATIONS FOR DEMOLITION OF A HIGHLY ALPHA CONTAMINATED BUILDING MODLES VERSUS MEASURED AIR & SURFACE ACTIVITY CONCENTRATIONS

    Energy Technology Data Exchange (ETDEWEB)

    LLOYD, E.R.

    2006-11-02

    The demolition of a facility historically used for processing and handling transuranic materials is considered. Residual alpha emitting radionuclide contamination poses an exposure hazard if released to the local environment during the demolition. The process of planning for the demolition of this highly alpha contaminated building, 232-Z, included a predemolition modeling analysis of potential exposures. Estimated emission rates were used as input to an air dispersion model to estimate frequencies of occurrence of peak air and surface exposures. Postdemolition modeling was also conducted, based on the actual demolition schedule and conditions. The modeling results indicated that downwind deposition is the main operational limitation for demolition of a highly alpha-contaminated building. During the demolition of 232-Z, airborne radiation and surface contamination were monitored. The resultant non-detect monitoring results indicate a significant level of conservatism in the modeled results. This comparison supports the use of more realistic assumption in the estimating emission rates. The resultant reduction in modeled levels of potential exposures has significant implications in terms of the projected costs of demolition of such structures.

  5. Surface contamination of counting tools after mock dispensing of cyclophosphamide in a simulated outpatient pharmacy.

    Science.gov (United States)

    Chaffee, Bruce W; Lander, Michael J; Christen, Catherine; Redic, Kimberly A

    2018-01-01

    Purpose The primary aim was to determine if dispensing of cyclophosphamide tablets resulted in accumulated residue on pharmacy counting tools during a simulated outpatient dispensing process. Secondary objectives included determining if cyclophosphamide contamination exceeded a defined threshold level of 1 ng/cm 2 and if a larger number of prescriptions dispensed resulted in increased contamination. Methods Mock prescriptions of 40 cyclophosphamide 50 mg tablets were counted on clean trays in three scenarios using a simulated outpatient pharmacy after assaying five cleaned trays as controls. The three scenarios consisted of five simulated dispensings of one, three, or six prescriptions dispensed per scenario. Wipe samples of trays and spatulas were collected and assayed for all trays, including the five clean trays used as controls. Contamination was defined as an assayed cyclophosphamide level at or above 0.001 ng/cm 2 and levels above 1 ng/cm 2 were considered sufficient to cause risk of human uptake. Mean contamination for each scenario was calculated and compared using one-way analysis of variance. P-values of contamination on trays used to count one, three, and six cyclophosphamide prescriptions was 0.51 ± 0.10 (p=0.0003), 1.02 ± 0.10 (p contamination. Increasing the number of prescriptions dispensed from 1 to 3, 1 to 6, and 3 to 6 counts increased contamination by 0.51 ± 0.15 (p = 0.0140), 1.31 + 0.15 (p contaminates pharmacy counting tools, and an increased number of prescriptions dispensed correlates with increased level of contamination. Counting out three or more prescriptions leads to trays having contamination that surpasses the threshold at which worker exposure may be increased. Pharmacies should consider devoting a separate tray to cyclophosphamide tablets, as cross-contamination could occur with other drugs and the efficacy of decontamination methods is unclear. Employee exposure could be minimized with the use

  6. [Legionella spp. contamination in indoor air: preliminary results of an Italian multicenter study].

    Science.gov (United States)

    Montagna, Maria Teresa; De Giglio, Osvalda; Napoli, Christian; Cannova, Lucia; Cristina, Maria Luisa; Deriu, Maria Grazia; Delia, Santi Antonino; Giuliano, Ada; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Mura, Ida; Pennino, Francesca; Rossini, Angelo; Tardivo, Stefano; Torre, Ida; Torregrossa, Maria Valeria; Villafrate, Maria Rosaria; Albertini, Roberto; Pasquarella, Cesira

    2014-01-01

    To propose a standardized protocol for the evaluation of Legionella contamination in air. A bathroom having a Legionella contamination in water >1,000 cfu/l was selected in 10 different healthcare facilities. Air contamination was assessed by active (Surface Air System, SAS) and passive (Index of Microbial Air, IMA) sampling for 8 hours, about 1 m away from the floor and 50 cm from the tap water. Two hundred liters of air were sampled by SAS every 12 min, after flushing water for 2 min. The IMA value was calculated as the mean value of colony forming units/16 plates exposed during sampling (2 plates/hour). Water contamination was evaluated at T0, after 4 and 8 hours, according to the standard methods. Air contamination by Legionella was found in three healthcare facilities (one with active and two with passive sampling), showing a concomitant tap water contamination (median=40,000; range 1,100-43,000 cfu/l). The remaining seven hospitals isolated Legionella spp. exclusively from water samples (median=8,000; range 1,200-70,000 cfu/l). Our data suggest that environmental Legionella contamination cannot be assessed only through the air sampling, even in the presence of an important water contamination.

  7. Contaminated site risk and uncertainty assessment for impacts on surface and groundwater

    DEFF Research Database (Denmark)

    Thomsen, Nanna Isbak

    available between sites and choosing between the need for further investigation or remediation. This is a question of prioritizing the sites that pose the greatest risk, and it is a matter of making decisions under uncertainty. Both tasks require a structured assessment of the risk posed by the contaminated...... sites. In a conventional risk assessment of a contaminated site, risk is evaluated by assessing whether a concentration guideline is exceeded at a specific point of compliance in the water resource of interest. If the guideline is exceeded, it is concluded that the site poses a risk. However......, a contaminated site may pose a threat to multiple water resources, or multiple contaminated sites may threaten a single water resource. For more advanced risk assessments, it is therefore relevant to develop methods that can handle this challenge. In this thesis, four contributions are made to the field...

  8. Evaluation of indigenously developed plastic scintillator sheet detector for surface radioactive contamination monitoring application

    International Nuclear Information System (INIS)

    Sahani, R.M.; Chaudhary, H.S.; Mahala, V.K.; Senwar, K.R.; Meena, J.P.

    2018-01-01

    Radioactive contamination may be caused by release of radioactivity in the environment due to accident at nuclear plant/reactor or spillage of loose radioactive materials in a laboratory. The protection of workers from potentially hazardous radiations emitted by the contaminants is a matter of prime concern. The detection of such radiations requires a monitoring system capable of measuring the level of radioactivity at the contaminated site. Plastic scintillators are widely used for large area radiation monitoring due to the ease of preparation in different shape and sizes. These detectors are sensitive to beta and gamma radiation therefore can be used for monitoring of beta and gamma contamination. In this paper, performance results of indigenously developed plastic scintillator sheet of area 800 cm 2 are reported

  9. Screening for contaminants of emerging concern in Northern Colorado Plateau Network waters: 2015 surface-water data

    Science.gov (United States)

    Weissinger, R; Battaglin, William A.; Bradley, Paul M.

    2016-01-01

    In 2015, as part of an on-going screening program for contaminants of emerging concern (CECs) in conjunction with the Environmental Protection Agency (EPA) Region 8, surface waters at 18 locations in or near seven national park units within the Northern Colorado Plateau Network (NCPN) were sampled for pesticides and pesticide degradation products, pharmaceuticals and personal care products, hormones, organic-wastewater-indictor chemicals, and nutrients. Most sites were sampled in spring (May or June) and fall (September).

  10. Quick Detection of Contaminants Leaching from Polypropylene Centrifuge Tube with Surface Enhanced Raman Spectroscopy and Ultra Violet Absorption Spectroscopy

    OpenAIRE

    Xu, Zhida; Liu, Logan

    2014-01-01

    Anomalous surface enhanced Raman scattering (SERS) peaks are identified for liquid sample stored in polypropylene centrifuge tubes (PP tube) for months. We observed the unexpected Raman peaks during experiments for Thiamine Hydrochloride aqueous solution stored in PP tube for two months. In order to identify the contaminants we have performed SERS experiments for de-ionized water (DI water) stored in polypropylene centrifuge tube for two months and compared them with fresh DI water sample. We...

  11. Mapping possible flowpaths of contaminants through surface and cross-borehole spectral time-domain induced polarization

    DEFF Research Database (Denmark)

    Bording, Thue Sylvester; Fiandaca, Gianluca; Maurya, Pradip Kumar

    Traditional methods for mapping possible flowpaths of contaminants in sedimentary environments by boreholes may often be insufficient. Additional information may be acquired by geophysical methods. In the present study, cross-borehole and surface measurements were performed using time-domain indu......-domain induced polarization (TDIP). After measurements the entire test site was dug out, and the geology was described. A 2D spectral inversion of the combined dataset is presented, which is in great correspondence with the observed geology....

  12. Determination of geohydrologic framework and extent of d- water contamination using surface geophysical techniques at Picatinny Arsenal, New Jersey

    Science.gov (United States)

    Lacombe, Pierre

    1986-01-01

    Seismic-refraction, electric-resistivity sounding, and electromagnetic conductivity techniques were used to determine the geohydrologic framework and extent of groundwater contamination at Picatinny Arsenal in northern New Jersey. The area studied encompasses about 4 sq mi at the southern end of the Arsenal. The bedrock surface beneath the glacial sediments was delineated by seismic-refraction techniques. Data for 12 seismic lines were collected using a 12-channel engineering seismograph. Competent bedrock crops out on both sides of the valley, but is about 290 ft below land surface in the deepest part of the topographic valley. Where the exposed bedrock surface forms steep slopes on the valley side, it remains steep below the valley fill. Likewise, gentle bedrock valley slopes have gentle subsurface slopes. The deepest part of the bedrock valley is along the southern extension of the Green Pond fault. The electric-resistivity sounding technique was used to determine the sediment types. Data were collected from four sites using the offset Wenner electrode configuration. Below the surface layer, the sediments have apparent and computed resistivity values of 120 to 170 ohm-meters. These values correspond to a saturated fine-grained sediment such as silt or interbedded sand and clay. Groundwater contamination was by electromagnetic conductivity techniques using transmitting and receiving coils separated by 32.8 ft and 12 ft. Thirteen sites have apparent conductivity values exceeding 15 millimhos/m. Of these, seven sites indicate groundwater contamination from a variety of sources including a sanitary landfill, pyrotechnic testing ground, burning area, former domestic sewage field, salt storage facility, hazardous waste disposal lagoon, sewage treatment plant, and fertilizer storage shed. Three areas underlain by clay or muck are interpreted to be free of contamination. (Author 's abstract)

  13. The deterioration during transport and storage of tomato fruits by microorganisms contaminating the surface and latent infected tissue

    OpenAIRE

    河野, 又四; 寺下, 隆夫

    1988-01-01

    [Author abstract]Deterioration during transport and storage of tomato fruits is generally thought to be caused by microorganisms contaminating the surface and latent infected tissue of apparently healthy fruit. Counts of viable airborne microorganisms showed that there were more in plastic greenhouses than in open culure of tomatoes. Altemaria, Aspergillus niger, Asp. oryzae, Cladosporium, Fusarium, Mucor, Penicillium, Trichoderma, Trichothecium, Bacillus, Erwinia and Pseudomonas were among t...

  14. The influence of TAP1 and TAP2 gene polymorphisms on TAP function and its inhibition by viral immune evasion proteins.

    Science.gov (United States)

    Praest, P; Luteijn, R D; Brak-Boer, I G J; Lanfermeijer, J; Hoelen, H; Ijgosse, L; Costa, A I; Gorham, R D; Lebbink, R J; Wiertz, E J H J

    2018-06-04

    Herpesviruses encode numerous immune evasion molecules that interfere with the immune system, particularly with certain stages in the MHC class I antigen presentation pathway. In this pathway, the transporter associated with antigen processing (TAP) is a frequent target of viral immune evasion strategies. This ER-resident transporter is composed of the proteins TAP1 and TAP2, and plays a crucial role in the loading of viral peptides onto MHC class I molecules. Several variants of TAP1 and TAP2 occur in the human population, some of which are linked to autoimmune disorders and susceptibility to infections. Here, we assessed the influence of naturally occurring TAP variants on peptide transport and MHC class I expression. In addition, we tested the inhibitory capacity of three viral immune evasion proteins, the TAP inhibitors US6 from human cytomegalovirus, ICP47 from herpes simplex virus type 1 and BNLF2a from Epstein-Barr virus, for a series of TAP1 and TAP2 variants. Our results suggest that these TAP polymorphisms have no or limited effect on peptide transport or MHC class I expression. Furthermore, our study indicates that the herpesvirus-encoded TAP inhibitors target a broad spectrum of TAP variants; inhibition of TAP is not affected by the naturally occurring polymorphisms of TAP tested in this study. Our findings suggest that the long-term coevolution of herpesviruses and their host did not result in selection of inhibitor-resistant TAP variants in the human population. Copyright © 2018. Published by Elsevier Ltd.

  15. Investigation of some regularities of the contamination of the surface snow in the ChAPP region in January-February 1987

    International Nuclear Information System (INIS)

    Glazunov, V.O.; Amosov, M.M.; Eldashev, V.V.; Draj, O.N.; Pashevich, V.I.

    1989-01-01

    The data on the surface snow radioactivity inspection obtained in winter 1987 are analyzed. A share of individual radionuclides in the general pollution of surface snow is considered. Changes in general and individual nuclide contamination dependent of the azimuth and distance are presented. A disperse content of contaminants in the surface snow is analyzed. The sampling techniques and snow sample preparation for γ-spectrometry are reported. 5 refs., 8 figs., 7 tabs

  16. Effectiveness of Modal Decomposition for Tapping Atomic Force Microscopy Microcantilevers in Liquid Environment.

    Science.gov (United States)

    Kim, Il Kwang; Lee, Soo Il

    2016-05-01

    The modal decomposition of tapping mode atomic force microscopy microcantilevers in liquid environments was studied experimentally. Microcantilevers with different lengths and stiffnesses and two sample surfaces with different elastic moduli were used in the experiment. The response modes of the microcantilevers were extracted as proper orthogonal modes through proper orthogonal decomposition. Smooth orthogonal decomposition was used to estimate the resonance frequency directly. The effects of the tapping setpoint and the elastic modulus of the sample under test were examined in terms of their multi-mode responses with proper orthogonal modes, proper orthogonal values, smooth orthogonal modes and smooth orthogonal values. Regardless of the stiffness of the microcantilever under test, the first mode was dominant in tapping mode atomic force microscopy under normal operating conditions. However, at lower tapping setpoints, the flexible microcantilever showed modal distortion and noise near the tip when tapping on a hard sample. The stiff microcantilever had a higher mode effect on a soft sample at lower tapping setpoints. Modal decomposition for tapping mode atomic force microscopy can thus be used to estimate the characteristics of samples in liquid environments.

  17. Evaluation on the Quality of Bangkok Tap Water with Other Drinking Purpose Water

    Science.gov (United States)

    Kordach, A.; Chardwattananon, C.; Wongin, K.; Chayaput, B.; Wongpat, N.

    2018-02-01

    The concern of drinking purposed water quality in Bangkok, Nonthaburi, and Samutprakarn provinces has been a problem for over fifteen years. Metropolitan Water Works Authority (MWA) of Thailand is fully responsible for providing water supply to the mentioned areas. The objective of Drinkable Tap Water Project is to make people realize in quality of tap water. Communities, school, government agencies, hotels, hospitals, department stores, and other organizations are participating in this project. MWA have collected at least 3 samples of water from the corresponding places and the samples have to meet the World Health Organization (WHO) guidelines level. This study is to evaluate water quality of tap water, storage water, filtered water, and filtered water dispenser. The water samples from 2,354 attending places are collected and analyzed. From October 2011 to September 2016, MWA analyzed 32,711 samples. The analyzed water parameters are free residual chlorine, appearance color, turbidity, pH, conductivity, total dissolved solids (TDS), and pathogenic bacteria; E.coli. The results indicated that a number of tap water samples had the highest number compliance with WHO guidelines levels at 98.40%. The filtered water, filtered water dispenser, and storage water were received 96.71%, 95.63%, and 90.88%, respectively. However, the several samples fail to pass WHO guideline level because they were contaminated by E.coli. The result is that tap water has the highest score among other sources probably because tap water has chlorine for disinfection and always is monitored by professional team round-the-clock services compared to the other water sources with less maintenance or cleaning. Also, water quality reports are continuously sent to customers by mail addresses. Tap water quality data are shown on MWA websites and Facebook. All these steps of work should enhance the confidence of tap water quality.

  18. Evaluation on the Quality of Bangkok Tap Water with Other Drinking Purpose Water

    Directory of Open Access Journals (Sweden)

    Kordach A.

    2018-01-01

    Full Text Available The concern of drinking purposed water quality in Bangkok, Nonthaburi, and Samutprakarn provinces has been a problem for over fifteen years. Metropolitan Water Works Authority (MWA of Thailand is fully responsible for providing water supply to the mentioned areas. The objective of Drinkable Tap Water Project is to make people realize in quality of tap water. Communities, school, government agencies, hotels, hospitals, department stores, and other organizations are participating in this project. MWA have collected at least 3 samples of water from the corresponding places and the samples have to meet the World Health Organization (WHO guidelines level. This study is to evaluate water quality of tap water, storage water, filtered water, and filtered water dispenser. The water samples from 2,354 attending places are collected and analyzed. From October 2011 to September 2016, MWA analyzed 32,711 samples. The analyzed water parameters are free residual chlorine, appearance color, turbidity, pH, conductivity, total dissolved solids (TDS, and pathogenic bacteria; E.coli. The results indicated that a number of tap water samples had the highest number compliance with WHO guidelines levels at 98.40%. The filtered water, filtered water dispenser, and storage water were received 96.71%, 95.63%, and 90.88%, respectively. However, the several samples fail to pass WHO guideline level because they were contaminated by E.coli. The result is that tap water has the highest score among other sources probably because tap water has chlorine for disinfection and always is monitored by professional team round-the-clock services compared to the other water sources with less maintenance or cleaning. Also, water quality reports are continuously sent to customers by mail addresses. Tap water quality data are shown on MWA websites and Facebook. All these steps of work should enhance the confidence of tap water quality.

  19. Mapping the environmental risk potential on surface water of pesticide contamination in the Prosecco's vineyard terraced landscape

    Science.gov (United States)

    Pizarro, Patricia; Ferrarese, Francesco; Loddo, Donato; Eugenio Pappalardo, Salvatore; Varotto, Mauro

    2016-04-01

    Intensive cropping systems today represent a paramount issue in terms of environmental impacts, since agricultural pollutants can constitute a potential threat to surface water, non-target organisms and aquatic ecosystems. Levels of pesticide concentrations in surface waters are indeed unquestionably correlated to crop and soil management practices at field-scale. Due to the numerous applications of pesticides required, orchards and vineyards can represent relevant non-point sources for pesticide contamination of water bodies, mainly prompted by soil erosion, surface runoff and spray drift. To reduce risks of pesticide contamination of surface water, the Directive 2009/128/CET imposed the local implementation of agricultural good practices and mitigation actions such as the use of vegetative buffer filter strips and hedgerows along river and pond banks. However, implementation of mitigation actions is often difficult, especially in extremely fragmented agricultural landscapes characterized by a complex territorial matrix set up on urban sprawling, frequent surface water bodies, important geomorphological processes and protected natural areas. Typically, such landscape matrix is well represented by the, Prosecco-DOCG vineyards area (NE of Italy, Province of Treviso) which lays on hogback hills of conglomerate, marls and sandstone that ranges between 50 and 500 m asl. Moreover such vineyards landscape is characterized by traditional and non-traditional agricultural terraces The general aim of this paper is to identify areas of surface water bodies with high potential risk of pesticide contamination from surrounding vineyards in the 735 ha of Lierza river basin (Refrontolo, TV), one of the most representative terraced landscape of the Prosecco-DOCG area. Specific aims are i) mapping terraced Prosecco-DOCG vineyards, ii) classifying potential risk from pesticide of the different areas. Remote sensing technologies such as four bands aerial photos (RGB+NIR) and Light

  20. Energy-Saving RAM-Power Tap

    Science.gov (United States)

    Bruner, Alan Roy

    1987-01-01

    Reverse-flow HEXFET(R) minimizes voltage drop and power dissipation. HEXFET(R) scheme reduces voltage drop by approximately 80 percent. Design for power tap for random-access memory (RAM) has potential application in digital systems.

  1. Sinusitis from Nontuberculous Mycobacteria in Tap Water

    Centers for Disease Control (CDC) Podcasts

    Dr. Wellington S. Tichenor. Associate Clinical Professor of Medicine at New York Medical College and in private practice in Manhattan, New York, discusses his investigation of sinusitis from nontuberculous mycobacteria in tap water.

  2. An integrated model for assessing the risk of TCE groundwater contamination to human receptors and surface water ecosystems

    DEFF Research Database (Denmark)

    McKnight, Ursula S.; Funder, S.G.; Rasmussen, J.J.

    2010-01-01

    The practical implementation of the European Water Framework Directive has resulted in an increased focus on the hyporheic zone. In this paper, an integrated model was developed for evaluating the impact of point sources in groundwater on human health and surface water ecosystems....... This was accomplished by coupling the system dynamics-based decision support system CARO-PLUS to the aquatic ecosystem model AQUATOX using an analytical volatilization model for the stream. The model was applied to a case study where a TCE contaminated groundwater plume is discharging to a stream. The TCE source...... will not be depleted for many decades, however measured and predicted TCE concentrations in surface water were found to be below human health risk management targets. Volatilization rapidly attenuates TCE concentrations in surface water. Thus, only a 300 m stream reach fails to meet surface water quality criteria...

  3. Ormen Lange hot tap - a world record

    Energy Technology Data Exchange (ETDEWEB)

    Apeland, Kjell Edvard

    2010-07-01

    For the last 10 years Statoil have been developing a new concept for performing subsea Hot Tap operations remotely controlled. The system was first used offshore in 2008 during a partly diver assisted operation, connecting the Tampen Link pipeline to the Statfjord Intrafield pipeline. In July 2009, the Hot Tap System successfully performed two remotely controlled Hot Taps, on a world record depth of 860 meters on the Ormen Lange field operated by Shell. The Hot Tap technology enables existing pipeline architecture to be modified, without interfering with the current production. Most of the technology is depth independent and the system is currently qualified to 1000 meter depth. Phase II of this project which involves development and construction of a retrofit Tee, thus enabling installation and welding of a Tee on an unprepared pipeline is well underway. This presentation will describe experiences from the development of the Remote Hot Tap system and give an overview of the offshore operations leading to the conclusion of the world's deepest Hot Taps. (Author)

  4. Sources, pathways, and relative risks of contaminants in surface water and groundwater: a perspective prepared for the Walkerton inquiry.

    Science.gov (United States)

    Ritter, Len; Solomon, Keith; Sibley, Paul; Hall, Ken; Keen, Patricia; Mattu, Gevan; Linton, Beth

    2002-01-11

    On a global scale, pathogenic contamination of drinking water poses the most significant health risk to humans, and there have been countless numbers of disease outbreaks and poisonings throughout history resulting from exposure to untreated or poorly treated drinking water. However, significant risks to human health may also result from exposure to nonpathogenic, toxic contaminants that are often globally ubiquitous in waters from which drinking water is derived. With this latter point in mind, the objective of this commission paper is to discuss the primary sources of toxic contaminants in surface waters and groundwater, the pathways through which they move in aquatic environments, factors that affect their concentration and structure along the many transport flow paths, and the relative risks that these contaminants pose to human and environmental health. In assessing the relative risk of toxic contaminants in drinking water to humans, we have organized our discussion to follow the classical risk assessment paradigm, with emphasis placed on risk characterization. In doing so, we have focused predominantly on toxic contaminants that have had a demonstrated or potential effect on human health via exposure through drinking water. In the risk assessment process, understanding the sources and pathways for contaminants in the environment is a crucial step in addressing (and reducing) uncertainty associated with estimating the likelihood of exposure to contaminants in drinking water. More importantly, understanding the sources and pathways of contaminants strengthens our ability to quantify effects through accurate measurement and testing, or to predict the likelihood of effects based on empirical models. Understanding the sources, fate, and concentrations of chemicals in water, in conjunction with assessment of effects, not only forms the basis of risk characterization, but also provides critical information required to render decisions regarding regulatory

  5. The degradation behaviour of nine diverse contaminants in urban surface water and wastewater prior to water treatment.

    Science.gov (United States)

    Cormier, Guillaume; Barbeau, Benoit; Arp, Hans Peter H; Sauvé, Sébastien

    2015-12-01

    An increasing diversity of emerging contaminants are entering urban surface water and wastewater, posing unknown risks for the environment. One of the main contemporary challenges in ensuring water quality is to design efficient strategies for minimizing such risks. As a first step in such strategies, it is important to establish the fate and degradation behavior of contaminants prior to any engineered secondary water treatment. Such information is relevant for assessing treatment solutions by simple storage, or to assess the impacts of contaminant spreading in the absence of water treatment, such as during times of flooding or in areas of poor infrastructure. Therefore in this study we examined the degradation behavior of a broad array of water contaminants in actual urban surface water and wastewater, in the presence and absence of naturally occurring bacteria and at two temperatures. The chemicals included caffeine, sulfamethoxazole, carbamazepine, atrazine, 17β-estradiol, ethinylestradiol, diclofenac, desethylatrazine and norethindrone. Little information on the degradation behavior of these pollutants in actual influent wastewater exist, nor in general in water for desethylatrazine (a transformation product of atrazine) and the synthetic hormone norethindrone. Investigations were done in aerobic conditions, in the absence of sunlight. The results suggest that all chemicals except estradiol are stable in urban surface water, and in waste water neither abiotic nor biological degradation in the absence of sunlight contribute significantly to the disappearance of desethylatrazine, atrazine, carbamazepine and diclofenac. Biological degradation in wastewater was effective at transforming norethindrone, 17β-estradiol, ethinylestradiol, caffeine and sulfamethoxazole, with measured degradation rate constants k and half-lives ranging respectively from 0.0082-0.52 d(-1) and 1.3-85 days. The obtained degradation data generally followed a pseudo-first-order-kinetic model

  6. Beer tapping: dynamics of bubbles after impact

    Science.gov (United States)

    Mantič-Lugo, V.; Cayron, A.; Brun, P.-T.; Gallaire, F.

    2015-12-01

    Beer tapping is a well known prank where a bottle of beer is impacted from the top by a solid object, usually another bottle, leading to a sudden foam overflow. A description of the shock-driven bubble dynamics leading to foaming is presented based on an experimental and numerical study evoking the following physical picture. First, the solid impact produces a sudden downwards acceleration of the bottle creating a strong depression in the liquid bulk. The existing bubbles undergo a strong expansion and a sudden contraction ending in their collapse and fragmentation into a large amount of small bubbles. Second, the bubble clouds present a large surface area to volume ratio, enhancing the CO2 diffusion from the supersaturated liquid, hence growing rapidly and depleting the CO2. The clouds of bubbles migrate upwards in the form of plumes pulling the surrounding liquid with them and eventually resulting in the foam overflow. The sudden pressure drop that triggers the bubble dynamics with a collapse and oscillations is modelled by the Rayleigh-Plesset equation. The bubble dynamics from impact to collapse occurs over a time (tb ≃ 800 μs) much larger than the acoustic time scale of the liquid bulk (tac = 2H/c ≃ 80 μs), for the experimental container of height H = 6 cm and a speed of sound around c ≃ 1500 m/s. This scale separation, together with the comparison of numerical and experimental results, suggests that the pressure drop is controlled by two parameters: the acceleration of the container and the distance from the bubble to the free surface.

  7. ASSESSMENTOF BETA PARTICLE FLUX FROM SURFACE CONTAMINATION AS A RELATIVE INDICATOR FOR RADIONUCLIDE DISTRIBUTION ON EXTERNAL SURFACES OF A MULTI-STORY BUILDING IN PRIPYAT

    Energy Technology Data Exchange (ETDEWEB)

    Farfan, E.

    2009-11-17

    How would we recover if a Radiological Dispersion Device (e.g., dirty bomb) or Improvised Nuclear Device were to detonate in a large city? In order to assess the feasibility of remediation following such an event, several issues would have to be considered, including the levels and characteristics of the radioactive contamination, the availability of the required resources to accomplish decontamination, and the planned future use of the city's structures and buildings. Presently little is known about the distribution, redistribution, and migration of radionuclides in an urban environment. However, Pripyat, a city substantially contaminated by the Chernobyl Nuclear Power Plant accident, may provide some answers. The main objective of this study was to determine the radionuclide distribution on a Pripyat multi-story building, which had not been previously decontaminated and therefore could reflect the initial fallout and its further natural redistribution on external surfaces. The 7-story building selected was surveyed from the ground floor to the roof on horizontal and vertical surfaces along seven ground-to-roof transections. Some of the results from this study indicate that the upper floors of the building had higher contamination levels than the lower floors. The authors consequently recommend that existing decontamination procedures for tall structures be re-examined and modified accordingly.

  8. The role of atmospheric precipitation in introducing contaminants to the surface waters of the Fuglebekken catchment, Spitsbergen

    Directory of Open Access Journals (Sweden)

    Katarzyna Kozak

    2015-11-01

    Full Text Available Although the Svalbard Archipelago is located at a high latitude, far from potential contaminant sources, it is not free from anthropogenic impact. Towards the Fuglebekken catchment, in the southern part of Spitsbergen, north of Hornsund fjord, contaminants can be transported from mainland pollution sources. In the precipitation and surface water collected in the catchment, the following elements were detected and quantified: Ag, Al, As, B, Ba, Bi, Ca, Cd, Co, Cr, Cu, Cs, Mo, Ni, Pb, Sb, Se, Sr, Tl, U, V and Zn. Additionally, pH, electrical conductivity and total organic carbon (TOC were determined in those samples. The acidic reaction of precipitation waters was identified as an important factor intensifying the metal migration in this Arctic tundra environment. The air mass trajectory, surprisingly, explained the variability of only a small fraction of trace elements in precipitation water. The air mass origin area was correlated only with the concentrations of As, V and Cr. Wind directions were helpful in explaining the variability of Mn, U and Ba concentrations (east–north-easterly wind and the contents of B, As, Rb, Se, Sr and Li in precipitation (south-westerly wind, which may indicate the local geological source of those. Atmospheric deposition was found to play a key role in the transport of contaminants into the Fuglebekken catchment; however, the surface water composition was modified by its pH and TOC content.

  9. Fiber-optic Fourier transform infrared spectroscopy for remote label-free sensing of medical device surface contamination

    Science.gov (United States)

    Hassan, Moinuddin; Tan, Xin; Welle, Elissa; Ilev, Ilko

    2013-05-01

    As a potential major source of biochemical contamination, medical device surfaces are of critical safety concerns in the clinical practice and public health. The development of innovative sensing methods for accurate and real-time detection of medical device surface contamination is essential to protect patients from high risk infection. In this paper, we demonstrate an alternative fiber-optic Fourier Transform Infrared (FTIR) spectroscopy based sensing approach for remote, non-contact, and label-free detection of biochemical contaminants in the mid-infrared (mid-IR) region. The sensing probe is designed using mid-IR hollow fibers and FTIR measurements are carried out in reflection mode. Bovine Serum Albumin (BSA) and bacterial endotoxin of different concentrations under thoroughly dry condition are used to evaluate the detection sensitivity. The devised system can identify ≤0.0025% (≤4 × 1011 molecules) BSA and 0.5% (0.5 EU/ml) endotoxin concentration. The developed sensing approach may be applied to detect various pathogens that pose public health threats.

  10. Contamination of the ground waters and surface waters by boron in Lerma Valley, NW-Argentina - an inventory

    International Nuclear Information System (INIS)

    Bundschuh, J.

    1992-01-01

    Ground- and surface waters in areas unaffected by pollution from borax and boric acid producing plants exhibit low boron concentrations of less than 300 μg B/l. Only at the boric acid plant 'Mineratea' is the groundwater contaminated, with up to 6200 μg B/l occurring within an area of 8 to 10 km 2 with more than 1000 μg boron/l. Even higher boron concentrations (up to 18 μg B/l) are present in polluted surface waters. Not the boron concentration in the irrigation water, but the absolute amount of boron added to the plants by irrigation is what determines plant toxicity. For the contaminated area of the boric acid 'Mineratea', characterized by boron concentrations of between 1000 and 6000 μg B/l, the maximal amounts of irrigation water that can be applied lies between 300 and 8 mm. In order to protect the local groundwater resoures from present and future contamination, environmental impact assessment on industrial projects in the area are required. In this way, the quality of the drinking and irrigation water can be guaranteed through suitable measures, without hindering further necessary industrial development of the region. (orig./UWA) [de

  11. Chemical speciation and contamination assessment of Pb and V by sequential extraction in surface sediment off Nile Delta, Egypt

    Directory of Open Access Journals (Sweden)

    Maha Ahmed Mohamed Abdallah

    2017-01-01

    The total concentrations of metals were ranged (22.8–41.3 μg g−1 for Pb and (66.6–142.5 μg g−1 for V. The chemical speciation in most sampling stations was in the order of Residual > acid-reducible > oxidizable-organic > exchangeable for Pb and in the order of Residual > oxidizable-organic > exchangeable > acid-reducible for V. The results showed that the Pb in surface sediments off Nile River Delta existed in the nonresistant fractions while vanadium existed in the resistant fractions. The degree of surface sediments contamination was determined for individual contamination factors (ICF and global contamination factor (GCF. The result of ICF and GCF values showed that those stations located in the vicinity of municipal area (especially Lake Burullus outlet had high potential risk to fauna and flora of study area. Risk assessment code (RAC analysis indicated that although Pb presented a moderate overall risk to the aquatic environment, vanadium showed a low risk (RAC < 10% at six sites.

  12. A review of diazinon use, contamination in surface waters, and regulatory actions in California across water years 1992-2014.

    Science.gov (United States)

    Wang, Dan; Singhasemanon, Nan; Goh, Kean S

    2017-07-01

    Diazinon is an organophosphorus insecticide that has been widely used in the USA and in California resulting in contamination of surface waters. Several federal and state regulations have been implemented with the aim of reducing its impact to human health and the environment, e.g., the cancellation of residential use products by the USEPA and dormant spray regulations by the California Department of Pesticide Regulation. This study reviewed the change in diazinon use and surface water contamination in accordance with the regulatory actions implemented in California over water years 1992-2014. We observed that use amounts began declining when agencies announced the intention to regulate certain use patterns and continued to decline after the implementation of those programs and regulations. The reduction in use amounts led to a downward trend in concentration data and exceedance frequencies in surface waters. Moreover, we concluded that diazinon concentrations in California's surface waters in recent years (i.e., water years 2012-2014) posed a de minimis risk to aquatic organisms.

  13. Effective decolorization and adsorption of contaminant from industrial dye effluents using spherical surfaced magnetic (Fe_3O_4) nanoparticles

    International Nuclear Information System (INIS)

    Suriyaprabha, R.; Khan, Samreen Heena; Pathak, Bhawana; Fulekar, M. H.

    2016-01-01

    Treatment of highly concentrated Industrial dye stuff effluents released in the environment is the major issue faced in the era of waste management as well as in water pollution. Though there is availability of conventional techniques in large numbers, there is a need of efficient and effective advance technologies. In account of that, Nanotechnology plays a prominent role to treat the heavy metals, organic and inorganic contaminants using smart materials in nano regime (1 -100 nm). Among these nanomaterials like Iron Oxide (Fe_3O_4, magnetic nanoparticle) is one of the most promising candidates to remove the heavy metals from the industrial effluent. Fe_3O_4 is the widely used smart material with magnetic property having high surface area; high surface to volume ratio provides more surface for the chemical reaction for the surface adsorption. Fe_3O_4 nanoparticles have been synthesized using sonochemical method using ultra frequency in aqueous solution under optimized conditions. The as-synthesized nanoparticle was analyzed using different characterization tool. The Transmission Electron microscope (TEM) images revealed 10-12 nm spherical shape nanoparticles; crystal phase and surface morphology was confirmed by X-Ray Diffraction (XRD) and Scanning Electron Microscopy (SEM), respectively. The functional group were identified by Fourier Transform-Infra Red Spectroscopy (FT-IR), revealed the bending and stretching vibrations associated with Iron Oxide nanoparticle. In present study, for the efficient removal of contaminants, different concentration (10-50 ppm) of dye stuff effluent has been prepared and subjected to adsorption and decolourization at definite time intervals with Fe_3O_4 nanoparticles. The concentration of Iron oxide and the time (45 mins) was kept fixed for the reaction whereas the concentration of dye stuff effluent was kept varying. It was found that the spherical shaped Fe_3O_4 proved to be the potential material for the adsorption of

  14. Reduction in infection risk through treatment of microbially contaminated surfaces with a novel, portable, saturated steam vapor disinfection system.

    Science.gov (United States)

    Tanner, Benjamin D

    2009-02-01

    Surface-mediated infectious disease transmission is a major concern in various settings, including schools, hospitals, and food-processing facilities. Chemical disinfectants are frequently used to reduce contamination, but many pose significant risks to humans, surfaces, and the environment, and all must be properly applied in strict accordance with label instructions to be effective. This study set out to determine the capability of a novel chemical-free, saturated steam vapor disinfection system to kill microorganisms, reduce surface-mediated infection risks, and serve as an alternative to chemical disinfectants. High concentrations of Escherichia coli, Shigella flexneri, vancomycin-resistant Enterococcus faecalis (VRE), methicillin-resistant Staphylococcus aureus (MRSA), Salmonella enterica, methicillin-sensitive Staphylococcus aureus, MS2 coliphage (used as a surrogate for nonenveloped viruses including norovirus), Candida albicans, Aspergillus niger, and the endospores of Clostridium difficile were dried individually onto porous clay test surfaces. Surfaces were treated with the saturated steam vapor disinfection system for brief periods and then numbers of surviving microorganisms were determined. Infection risks were calculated from the kill-time data using microbial dose-response relationships published in the scientific literature, accounting for surface-to-hand and hand-to-mouth transfer efficiencies. A diverse assortment of pathogenic microorganisms was rapidly killed by the steam disinfection system; all of the pathogens tested were completely inactivated within 5 seconds. Risks of infection from the contaminated surfaces decreased rapidly with increasing periods of treatment by the saturated steam vapor disinfection system. The saturated steam vapor disinfection system tested for this study is chemical-free, broadly active, rapidly efficacious, and therefore represents a novel alternative to liquid chemical disinfectants.

  15. Mathematical modeling the cross-contamination of Escherichia coli O157:H7 on the surface of ready-to-eat meat product while slicing

    Science.gov (United States)

    Microbial cross-contamination either at home or production site is one of the major factors of causing contamination of foods and leading to the foodborne illness. The knowledge regarding Escherichia coli O157:H7 surface transfer on ready-to-eat (RTE) deli meat and the slicer used for slicing diffe...

  16. Contamination of ground water, surface water, and soil, and evaluation of selected ground-water pumping alternatives in the Canal Creek area of Aberdeen Proving Ground, Maryland

    Science.gov (United States)

    Lorah, Michelle M.; Clark, Jeffrey S.

    1996-01-01

    Chemical manufacturing, munitions filling, and other military-support activities have resulted in the contamination of ground water, surface water, and soil in the Canal Creek area of Aberdeen Proving Ground, Maryland. Chlorinated volatile organic compounds, including 1,1,2,2-tetrachloroethane and trichloroethylene, are widespread ground-water contaminants in two aquifers that are composed of unconsolidated sand and gravel. Distribution and fate of chlorinated organic compounds in the ground water has been affected by the movement and dissolution of solvents in their dense immiscible phase and by microbial degradation under anaerobic conditions. Detection of volatile organic contaminants in adjacent surface water indicates that shallow contaminated ground water discharges to surface water. Semivolatile organic compounds, especially polycyclic aromatic hydrocarbons, are the most prevalent organic contaminants in soils. Various trace elements, such as arsenic, cadmium, lead, and zinc, were found in elevated concentrations in ground water, surface water, and soil. Simulations with a ground-water-flow model and particle tracker postprocessor show that, without remedial pumpage, the contaminants will eventually migrate to Canal Creek and Gunpowder River. Simulations indicate that remedial pumpage of 2.0 million gallons per day from existing wells is needed to capture all particles originating in the contaminant plumes. Simulated pumpage from offsite wells screened in a lower confined aquifer does not affect the flow of contaminated ground water in the Canal Creek area.

  17. Reduction of microbial contamination and improvement of germination of sweet basil (Ocimum basilicum L.) seeds via surface dielectric barrier discharge

    Science.gov (United States)

    Ambrico, Paolo F.; Šimek, Milan; Morano, Massimo; De Miccolis Angelini, Rita M.; Minafra, Angelantonio; Trotti, Pasquale; Ambrico, Marianna; Prukner, Václav; Faretra, Francesco

    2017-08-01

    Naturally contaminated basil seeds were treated by a surface dielectric barrier discharge driven in the humid air by an amplitude modulated AC high voltage to avoid heat shock. In order to avoid direct contact of seeds with microdischarge filaments, the seeds to be treated were placed at sufficient distance from the surface discharge. After treatment, the seeds were analyzed in comparison with control samples for their microbial contamination as well as for the capability of germination and seedling growth. Moreover, chemical modification of seed surface was observed through the elemental energy dispersive x-ray analysis and wettability tests. We found that treatment applied at 20% duty cycle (effective discharge duration up to 20 s) significantly decreases microbial load without reducing the viability of the seeds. On the other side, seedling growth was considerably accelerated after the treatment, and biometric growth parameters of seedlings (total length, weight, leaf extension) considerably increased compared to the controls. Interestingly, scanning electron microscopy images taken for the different duration of treatment revealed that seed radicle micropylar regions underwent significant morphological changes while the coat was substantially undamaged. Inside the seed, the embryo seemed to be well preserved while the endosperm body was detached from the epithelial tegument. A total of 9 different genera of fungi were recovered from the analyzed seeds. Scanning electron microscopy images revealed that conidia were localized especially in the micropylar region, and after plasma treatment, most of them showed substantial damages. Therefore, the overall effect of the treatment of naturally contaminated seeds by reactive oxygen and nitrogen species produced by plasma and the consequent changes in surface chemistry and microbial load can significantly improve seed vigor.

  18. Reduction of microbial contamination and improvement of germination of sweet basil ( Ocimum basilicum L.) seeds via surface dielectric barrier discharge

    International Nuclear Information System (INIS)

    Ambrico, Paolo F; Ambrico, Marianna; Šimek, Milan; Prukner, Václav; Morano, Massimo; De Miccolis Angelini, Rita M; Trotti, Pasquale; Faretra, Francesco; Minafra, Angelantonio

    2017-01-01

    Naturally contaminated basil seeds were treated by a surface dielectric barrier discharge driven in the humid air by an amplitude modulated AC high voltage to avoid heat shock. In order to avoid direct contact of seeds with microdischarge filaments, the seeds to be treated were placed at sufficient distance from the surface discharge. After treatment, the seeds were analyzed in comparison with control samples for their microbial contamination as well as for the capability of germination and seedling growth. Moreover, chemical modification of seed surface was observed through the elemental energy dispersive x-ray analysis and wettability tests. We found that treatment applied at 20% duty cycle (effective discharge duration up to 20 s) significantly decreases microbial load without reducing the viability of the seeds. On the other side, seedling growth was considerably accelerated after the treatment, and biometric growth parameters of seedlings (total length, weight, leaf extension) considerably increased compared to the controls. Interestingly, scanning electron microscopy images taken for the different duration of treatment revealed that seed radicle micropylar regions underwent significant morphological changes while the coat was substantially undamaged. Inside the seed, the embryo seemed to be well preserved while the endosperm body was detached from the epithelial tegument. A total of 9 different genera of fungi were recovered from the analyzed seeds. Scanning electron microscopy images revealed that conidia were localized especially in the micropylar region, and after plasma treatment, most of them showed substantial damages. Therefore, the overall effect of the treatment of naturally contaminated seeds by reactive oxygen and nitrogen species produced by plasma and the consequent changes in surface chemistry and microbial load can significantly improve seed vigor. (paper)

  19. SURFACE-ALTERED ZEOLITES AS PERMEABLE BARRIERS FOR IN SITU TREATMENT OF CONTAMINATED GROUNDWATER

    International Nuclear Information System (INIS)

    Bowman, Robert S.; Li, Zhaohui; Roy, Stephen J.; Burt, Todd; Johnson, Timothy L.; Johnson, Richard L.

    1999-01-01

    The overall objective of this effort is to develop and test a zeolite-based permeable barrier system for containing and remediating contaminated groundwater. The projected product is an engineered and tested permeable barrier system that can be adopted by the commercial sector

  20. Detection of fecal contamination on beef meat surfaces using handheld fluorescence imaging device (HFID)

    Science.gov (United States)

    Current meat inspection in slaughter plants, for food safety and quality attributes including potential fecal contamination, is conducted through by visual examination human inspectors. A handheld fluorescence-based imaging device (HFID) was developed to be an assistive tool for human inspectors by ...

  1. Evaluation of dose to skin surface contamination in the factory Juzbado of fuel elements

    International Nuclear Information System (INIS)

    Ortiz Trujillo, D.; Agustin Perez Fonseca, A.; Alejandro Fuentes, A.

    2013-01-01

    The aim of this work is previously set a simple calculation methodology applicable to the boundary conditions surrounding the environment where skin contamination may have occurred so that you can evaluate in a simple and fast way the dose that the worker is receiving while enduring such pollution. (Author)

  2. Contamination problems from glass beaker inner surface in low level Po-210 analysis

    Czech Academy of Sciences Publication Activity Database

    Kameník, Jan; Hölgye, Z.

    2010-01-01

    Roč. 283, č. 2 (2010), s. 493-495 ISSN 0236-5731 Institutional research plan: CEZ:AV0Z10480505 Keywords : Po-210 * Low-level analysis * Contamination Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 0.777, year: 2010

  3. SURFACE-ALTERED ZEOLITES AS PERMEABLE BARRIERS FOR IN SITU TREATMENT OF CONTAMINATED GROUNDWATER

    Energy Technology Data Exchange (ETDEWEB)

    Robert S. Bowman; Zhaohui Li; Stephen J. Roy; Todd Burt; Timothy L. Johnson; Richard L. Johnson

    1999-08-30

    The overall objective of this effort is to develop and test a zeolite-based permeable barrier system for containing and remediating contaminated groundwater. The projected product is an engineered and tested permeable barrier system that can be adopted by the commercial sector.

  4. Decontamination of radioactively contaminated surfaces - Testing of decontamination agents for textiles. 1. ed.

    International Nuclear Information System (INIS)

    1992-01-01

    The present International Standard provides an experimental method for determining the efficiency of the agents for removal radionuclides deposited on textile materials. It applies to testing the detergents which might be used in water solution for cleaning textiles contaminated by radioactive elements. It is applicable for testing the efficiency of detergents for eliminating non-radioactive dirt

  5. Wind-induced contaminant transport in near-surface soils with application to radon entry into buildings

    Energy Technology Data Exchange (ETDEWEB)

    Riley, William Jowett [Univ. of California, Berkeley, CA (United States)

    1996-05-01

    Indoor air exposures to gaseous contaminants originating in soil can cause large human health risks. To predict and control these exposures, the mechanisms that affect vapor transport in near-surface soils need to be understood. In particular, radon exposure is a concern since average indoor radon concentrations lead to much higher risks than are generally accepted for exposure to other environmental contaminants. This dissertation examines an important component of the indoor radon problem: the impacts of wind on soil-gas and radon transport and entry into buildings. The research includes experimental and modeling studies of wind`s interactions with a building`s superstructure and the resulting soil-gas and radon flows in the surrounding soil. In addition to exploring the effects of steady winds, a novel modeling technique is developed to examine the impacts of fluctuating winds on soil-gas and radon transport.

  6. Wind-induced contaminant transport in near-surface soils with application to radon entry into buildings

    International Nuclear Information System (INIS)

    Riley, W.J.

    1996-05-01

    Indoor air exposures to gaseous contaminants originating in soil can cause large human health risks. To predict and control these exposures, the mechanisms that affect vapor transport in near-surface soils need to be understood. In particular, radon exposure is a concern since average indoor radon concentrations lead to much higher risks than are generally accepted for exposure to other environmental contaminants. This dissertation examines an important component of the indoor radon problem: the impacts of wind on soil-gas and radon transport and entry into buildings. The research includes experimental and modeling studies of wind's interactions with a building's superstructure and the resulting soil-gas and radon flows in the surrounding soil. In addition to exploring the effects of steady winds, a novel modeling technique is developed to examine the impacts of fluctuating winds on soil-gas and radon transport

  7. Microbial environmental contamination in Italian dental clinics: A multicenter study yielding recommendations for standardized sampling methods and threshold values.

    Science.gov (United States)

    Pasquarella, Cesira; Veronesi, Licia; Napoli, Christian; Castiglia, Paolo; Liguori, Giorgio; Rizzetto, Rolando; Torre, Ida; Righi, Elena; Farruggia, Patrizia; Tesauro, Marina; Torregrossa, Maria V; Montagna, Maria T; Colucci, Maria E; Gallè, Francesca; Masia, Maria D; Strohmenger, Laura; Bergomi, Margherita; Tinteri, Carola; Panico, Manuela; Pennino, Francesca; Cannova, Lucia; Tanzi, Marialuisa

    2012-03-15

    A microbiological environmental investigation was carried out in ten dental clinics in Italy. Microbial contamination of water, air and surfaces was assessed in each clinic during the five working days, for one week per month, for a three-month period. Water and surfaces were sampled before and after clinical activity; air was sampled before, after, and during clinical activity. A wide variation was found in microbial environmental contamination, both within the participating clinics and for the different sampling times. Before clinical activity, microbial water contamination in tap water reached 51,200cfu/mL (colony forming units per milliliter), and that in Dental Unit Water Systems (DUWSs) reached 872,000cfu/mL. After clinical activity, there was a significant decrease in the Total Viable Count (TVC) in tap water and in DUWSs. Pseudomonas aeruginosa was found in 2.38% (7/294) of tap water samples and in 20.06% (59/294) of DUWS samples; Legionella spp. was found in 29.96% (89/297) of tap water samples and 15.82% (47/297) of DUWS samples, with no significant difference between pre- and post-clinical activity. Microbial air contamination was highest during dental treatments, and decreased significantly at the end of the working activity (p<0.05). The microbial buildup on surfaces increased significantly during the working hours. This study provides data for the establishment of standardized sampling methods, and threshold values for contamination monitoring in dentistry. Some very critical situations have been observed which require urgent intervention. Furthermore, the study emphasizes the need for research aimed at defining effective managing strategies for dental clinics. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. The Use of Numerical Modeling to Address Surface and Subsurface Water Contamination due to Fracwater Spills in Larry's Creek, Pennsylvania

    Science.gov (United States)

    Simon, C. A.; Arjmand, S.; Abad, J. D.

    2012-12-01

    Because of its relatively low carbon dioxide emissions, natural gas is considered to be more efficient and environmentally friendly than other non-renewable fuels. As a result of this, among other factors, in recent years natural gas has become one of the world's primary energy sources. In the United States, drilling to extract natural gas has substantially increased over the past few years. In the Marcellus Shale, unconventional gas is currently extracted by using two new techniques: horizontal drilling and hydraulic fracturing. Today, fracking fluids which have been applied as part of the hydraulic fracturing process to fracture the shale rock and release the gas, pose a major environmental concern. These fluids are highly contaminated with radionuclides and toxic metals and any exposure of this highly polluted water to surface water or soil could heavily contaminate the media. The area selected for the current study is the Larry's Creek, located in Lycoming County in Pennsylvania. Larry's Creek Watershed was adversely affected by coal and iron mines activities in the 19th century. Though, the water quality in this creek was considered to be good as of 2006. Recently, oil and gas drilling activities have raised concerns about the creek's water quality again. A major environmental hazard is the freshwater contamination by frac/flowback water. Drilling companies are using impoundments on site to keep fracwater, and to store and evaporate flowback water. However, these ponds may fail or leak due to construction problems and/or accidents. Close to Saladasburg, Larry's Creek's stream was observed running rich with clay in October 19, 2011. Historical measurements show very high turbidity during this period which has raised questions about water contamination by the gas industry activities in the upper stream of the watershed. An interstate watershed agency has reported spills in Wolf Run in different drilling sites in the Larry's Creek basin. The focus of this study

  9. Contaminant profiles for surface water, sediment, flora and fauna associated with the mangrove fringe along middle and lower East Tampa Bay

    Science.gov (United States)

    Contaminant concentrations are reported for surface water, sediment, seagrass, mangroves, Florida Crown conch, blue crabs and fish collected during 2010-2011 from the mangrove fringe along eastern Tampa Bay. Concentrations of trace metals, chlorinated pesticides, atrazine, total ...

  10. Transport and transformation of pharmaceuticals and other contaminants of emerging concern from wastewater discharge through surface water to drinking water intake and treatment

    Science.gov (United States)

    The ubiquitous presence of pharmaceuticals, hormones, and other contaminants of emerging concern (CECs) in surface-water resources have necessitated research that better elucidates pathways of transport and transformation for these compounds from their discharged wastewater, thro...

  11. Contamination vs. Exposure

    Science.gov (United States)

    ... into the environment can cause air, water, surfaces, soil, plants, buildings, people, or animals to become contaminated. ... water to remove contamination. This process is called decontamination. Try to avoid spreading contamination to parts of ...

  12. Biomechanical loading on the upper extremity increases from single key tapping to directional tapping.

    Science.gov (United States)

    Qin, Jin; Trudeau, Matthieu; Katz, Jeffrey N; Buchholz, Bryan; Dennerlein, Jack T

    2011-08-01

    Musculoskeletal disorders associated with computer use span the joints of the upper extremity. Computing typically involves tapping in multiple directions. Thus, we sought to describe the loading on the finger, wrist, elbow and shoulder joints in terms of kinematic and kinetic difference across single key switch tapping to directional tapping on multiple keys. An experiment with repeated measures design was conducted. Six subjects tapped with their right index finger on a stand-alone number keypad placed horizontally in three conditions: (1) on single key switch (the number key 5); (2) left and right on number key 4 and 6; (3) top and bottom on number key 8 and 2. A force-torque transducer underneath the keypad measured the fingertip force. An active-marker infrared motion analysis system measured the kinematics of the fingertip, hand, forearm, upper arm and torso. Joint moments for the metacarpophalangeal, wrist, elbow, and shoulder joints were estimated using inverse dynamics. Tapping in the top-bottom orientation introduced the largest biomechanical loading on the upper extremity especially for the proximal joint, followed by tapping in the left-right orientation, and the lowest loading was observed during single key switch tapping. Directional tapping on average increased the fingertip force, joint excursion, and peak-to-peak joint torque by 45%, 190% and 55%, respectively. Identifying the biomechanical loading patterns associated with these fundamental movements of keying improves the understanding of the risks of upper extremity musculoskeletal disorders for computer keyboard users. Copyright © 2010 Elsevier Ltd. All rights reserved.

  13. The largest subsea hot tap (future tap flange) at Angel Field, Australia

    Energy Technology Data Exchange (ETDEWEB)

    Lad, Deepak; Drysdale, Colin [T.D. Williamson (United States); Naidoo, Sashie [T.D. Williamson (Australia)

    2008-07-01

    A subsea hot tap was conducted near the gas production platforms in Angel Field, Australia in September 2007 and verified as the largest no. 900 subsea hot tap by Australian authorities. This paper outlines the subsea tapping process, risks and safety issues in deep water environment, including the need to ensure 100% system accuracy and that the machine fluids used to operate the subsea tapping machines were environmentally friendly. The testing phase included land and water testing. In the land tests, issues relating to metal hardness, temperature, pressure and ocean currents that affected machine stability, torque and cutting rate were considered. All preliminary design and testing focused on being able to mount the tapping machine to a pre-existing hot-tap flange and conduct the tapping operation, start to finish, preferably without changing the cutter. The water depth tests took place inside a pressurized, underwater hyperbaric chamber. The equipment repeated the land testing process in conditions duplicating that of the actual project site. Timing was also measured in multiple climatic conditions (except water depth) to obtain an estimation of various scenarios. The field tapping process was conducted without problems in over six hours with a single cutter and without any stalls. (author)

  14. Contaminations of inner surface of magnesium fluoride windows in the `Expose-R' experiment on the International Space Station

    Science.gov (United States)

    Skurat, V. E.

    2017-10-01

    A series of experiments was carried out previously on board of the International Space Station in `EXPOSE-R', a multi-user expose facility, provided by European Space Agency attached to the external surface of the Russian Segment. In one experiment, spores of microorganisms and species of higher plant seeds, in heat-sealed polymer bags were irradiated by solar radiation passed through MgF2 windows in a high space vacuum. After sample exposure, it was found that in many cases the inner surfaces of windows were contaminated. Analysis of the contamination revealed the presence of chemical groups CH2, CH3, NH, OH, C═O, Si-CH3 (Demets et al. in 2015). Their presence in deposits was explained by photofixation of gaseous precursors - some of the vapours of glues and additives in polymeric materials in the core facility of `Expose-R'. Carbon-, oxygen- and silicon-containing groups may be deposited from outer intrinsic atmosphere. This atmosphere is connected with sample compartments and core facility. However, the presence of NH groups on inner surfaces of windows was not expected. This paper shows that the process responsible for carbon-, nitrogen- and oxygen-containing group formation can be a photopolymerization of caprolactam, which is released from the outer Nylon 6 layer of polymer bags under Solar vacuum ultraviolet radiation.

  15. Listeria monocytogenes contamination of the environment and surfaces of the equipment in the meat processing facilities in republic of Macedonia

    Directory of Open Access Journals (Sweden)

    Dean Jankuloski

    2007-11-01

    Full Text Available Listeria monocytogenes contamination of the environment and surfaces of the equipment was examined in seven meat processing facilities. Up to date prevalence of this foodborn pathogen in meat processing facilities facilities in Republic of Macedonia was unknown. Biofilms are composed from food spoilage microorganisms and food born pathogens. They are located on the surfaces of the equipment that come in contact with food and in facilities environment. Microorganisms in biofilm presenting micro eco system and are source of dissemination and contamination of food born pathogens in final meat products. During the preparation of this study we have covered a 7 meat processing facilities and we took a total of 39 swabs from surfaces that come in direct or indirect contact with food. Listeria monocytogenes was discovered in 10 (25,64% swabs (locations. Prevalence of other Listeria spp. compared with total number of taken samples was 15 (38,46% Listeria innocua, 3 (7,69% Listeria welshimeri and 1 (2,65% isolate Listeria seeligeri.

  16. More than just tapping: index finger-tapping measures procedural learning in schizophrenia.

    Science.gov (United States)

    Da Silva, Felipe N; Irani, Farzin; Richard, Jan; Brensinger, Colleen M; Bilker, Warren B; Gur, Raquel E; Gur, Ruben C

    2012-05-01

    Finger-tapping has been widely studied using behavioral and neuroimaging paradigms. Evidence supports the use of finger-tapping as an endophenotype in schizophrenia, but its relationship with motor procedural learning remains unexplored. To our knowledge, this study presents the first use of index finger-tapping to study procedural learning in individuals with schizophrenia or schizoaffective disorder (SCZ/SZA) as compared to healthy controls. A computerized index finger-tapping test was administered to 1169 SCZ/SZA patients (62% male, 88% right-handed), and 689 healthy controls (40% male, 93% right-handed). Number of taps per trial and learning slopes across trials for the dominant and non-dominant hands were examined for motor speed and procedural learning, respectively. Both healthy controls and SCZ/SZA patients demonstrated procedural learning for their dominant hand but not for their non-dominant hand. In addition, patients showed a greater capacity for procedural learning even though they demonstrated more variability in procedural learning compared to healthy controls. Left-handers of both groups performed better than right-handers and had less variability in mean number of taps between non-dominant and dominant hands. Males also had less variability in mean tap count between dominant and non-dominant hands than females. As expected, patients had a lower mean number of taps than healthy controls, males outperformed females and dominant-hand trials had more mean taps than non-dominant hand trials in both groups. The index finger-tapping test can measure both motor speed and procedural learning, and motor procedural learning may be intact in SCZ/SZA patients. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Demonstration/Validation of a Surface Cleaning Control to Mitigate Storm Water Metal Contaminants

    Science.gov (United States)

    2014-04-01

    added to a pre- weighed 125-ml low density polyethylene (LDPE) bottle. The particles were digested with 1.0 ml of concentrated trace metal grade (TMG...Sorenson. 2005. “ Residential Street-Dirt Accumulation Rates and Chemical Composition, and Removal Efficiencies by Mechanical- and Vacuum-Type...Bay, and M. Kayhanian. 2003. “A Review of the Contaminants and Toxicity Associated with Particles in Stormwater Runoff.” Caltrans CTSW-RT-03-059.73.15

  18. Demonstration/Validation of a Surface Cleaning Control Practice to Mitigate Storm Water Metal Contaminants

    Science.gov (United States)

    2014-04-01

    added to a pre- weighed 125-ml low density polyethylene (LDPE) bottle. The particles were digested with 1.0 ml of concentrated trace metal grade (TMG...consideration to ensure completion of operations.   33 9. REFERENCES Breault, R. F., K. P. Smith, and J. R. Sorenson. 2005. “ Residential Street...of the Contaminants and Toxicity Associated with Particles in Stormwater Runoff.” Caltrans CTSW-RT-03-059.73.15. California Department of

  19. The development of the American national standard, ''control of radioactive surface contamination on materials, equipment and facilities to be released for uncontrolled use''

    International Nuclear Information System (INIS)

    Shapiro, J.

    1980-01-01

    The American National Standard, Control of Radioactive Surface Contamination on Materials, Equipment and Facilities to be Released for Uncontrolled Use, was developed under the procedures of ANSI for ANSI Main Committee N13 (Radiation Protection) by a working group of the Health Physics Society Standards Committee. This standard provides criteria for the control of materials, equipment and facilities contaminated with radioactivity proposed to be released for uncontrolled use. Permissible contamination limits are specified as well as methods assessing the levels of contamination. This paper reviews the proceedings of the Subcommittee on Radioactive Surface Contamination, the comments received by reviewers of the standard, the resolution of the committee, and the bases for reaching the final limits, recommendations, and measurement procedures. (H.K.)

  20. Recent developments on surface contamination limits for packages and conveyances in transport regulations

    International Nuclear Information System (INIS)

    Thierfeldt, S.; Woerlen, S.; Lorenz, B.; Schwarz, W.

    2009-01-01

    The IAEA Regulations for the Safe Transport of Radioactive Material [1] contain requirements for contamination limits on packages and conveyances used for the transport of radioactive material. Current contamination limits for packages and conveyances under routine transport conditions have been derived from a model proposed by Fairbairn nearly 50 years ago [3]. This model has proven effective if used with pragmatism, but is based on very conservative as well as extremely simple assumptions which is in no way appropriate any more and which is not compatible with ICRP recommendations regarding radiation protection standards. Therefore, a new model has been developed over the last 8 years which reflects all steps of the transport process. The derivation of this model has been fostered by the IAEA by initiating a Co-ordinated Research Project (see section 2). The results of the calculations using this model could be directly applied as new nuclide specific transport limits for the non-fixed contamination. A corresponding regulatory text has been drafted by an IAEA technical meeting TM-36514, which was held in Tokyo November 10-14, 2008 (see section 4). (orig.)

  1. Recent developments on surface contamination limits for packages and conveyances in transport regulations

    Energy Technology Data Exchange (ETDEWEB)

    Thierfeldt, S.; Woerlen, S. [Brenk Systemplanung GmbH, Aachen (Germany); Lorenz, B. [GNS Gesellschaft fuer Nuklear-Service mbH, Essen (Germany); Schwarz, W. [VGB PowerTech e.V., Essen (Germany)

    2009-07-01

    The IAEA Regulations for the Safe Transport of Radioactive Material [1] contain requirements for contamination limits on packages and conveyances used for the transport of radioactive material. Current contamination limits for packages and conveyances under routine transport conditions have been derived from a model proposed by Fairbairn nearly 50 years ago [3]. This model has proven effective if used with pragmatism, but is based on very conservative as well as extremely simple assumptions which is in no way appropriate any more and which is not compatible with ICRP recommendations regarding radiation protection standards. Therefore, a new model has been developed over the last 8 years which reflects all steps of the transport process. The derivation of this model has been fostered by the IAEA by initiating a Co-ordinated Research Project (see section 2). The results of the calculations using this model could be directly applied as new nuclide specific transport limits for the non-fixed contamination. A corresponding regulatory text has been drafted by an IAEA technical meeting TM-36514, which was held in Tokyo November 10-14, 2008 (see section 4). (orig.)

  2. Role of surface energy and nano-roughness in the removal efficiency of bacterial contamination by nonwoven wipes from frequently touched surfaces

    Science.gov (United States)

    Edwards, Nicholas W. M.; Best, Emma L.; Connell, Simon D.; Goswami, Parikshit; Carr, Chris M.; Wilcox, Mark H.; Russell, Stephen J.

    2017-12-01

    Healthcare associated infections (HCAIs) are responsible for substantial patient morbidity, mortality and economic cost. Infection control strategies for reducing rates of transmission include the use of nonwoven wipes to remove pathogenic bacteria from frequently touched surfaces. Wiping is a dynamic process that involves physicochemical mechanisms to detach and transfer bacteria to fibre surfaces within the wipe. The purpose of this study was to determine the extent to which systematic changes in fibre surface energy and nano-roughness influence removal of bacteria from an abiotic polymer surface in dry wiping conditions, without liquid detergents or disinfectants. Nonwoven wipe substrates composed of two commonly used fibre types, lyocell (cellulosic) and polypropylene, with different surface energies and nano-roughnesses, were manufactured using pilot-scale nonwoven facilities to produce samples of comparable structure and dimensional properties. The surface energy and nano-roughness of some lyocell substrates were further adjusted by either oxygen (O2) or hexafluoroethane (C2F6) gas plasma treatment. Static adpression wiping of an inoculated surface under dry conditions produced removal efficiencies of between 9.4% and 15.7%, with no significant difference (p < 0.05) in the relative removal efficiencies of Escherichia coli, Staphylococcus aureus or Enterococcus faecalis. However, dynamic wiping markedly increased peak wiping efficiencies to over 50%, with a minimum increase in removal efficiency of 12.5% and a maximum increase in removal efficiency of 37.9% (all significant at p < 0.05) compared with static wiping, depending on fibre type and bacterium. In dry, dynamic wiping conditions, nonwoven wipe substrates with a surface energy closest to that of the contaminated surface produced the highest E. coli removal efficiency, while the associated increase in fibre nano-roughness abrogated this trend with S. aureus and E. faecalis.

  3. Process and associated equipment for decontaminating, cleaning all surfaces which are covered with transferrable contamination of a nuclear nature, without creating other wastes

    International Nuclear Information System (INIS)

    Tiesse, J.-C.G.; Chauvet, S.; Chabert, R.E.; Dezu, M.D.

    1989-01-01

    The invention relates to a process for removing all transferrable contamination of a nuclear nature without creating new nuclear contamination wastes. This process is characterised by the following three stages: spraying and covering the contaminated surfaces with dry ice, without causing any blast; spraying a jet of steam or hot air on to the coated surfaces from very close range; forced ventilation causing total evaporation of the dry ice, bringing about the phenomenon of sublimation. The device for applying the process comprises a dry ice emitter and a spray nozzle for water vapour at a temperature in excess of 70 0 C. (author)

  4. PeakForce Tapping resolves individual microvilli on living cells.

    Science.gov (United States)

    Schillers, Hermann; Medalsy, Izhar; Hu, Shuiqing; Slade, Andrea L; Shaw, James E

    2016-02-01

    Microvilli are a common structure found on epithelial cells that increase the apical surface thus enhancing the transmembrane transport capacity and also serve as one of the cell's mechanosensors. These structures are composed of microfilaments and cytoplasm, covered by plasma membrane. Epithelial cell function is usually coupled to the density of microvilli and its individual size illustrated by diseases, in which microvilli degradation causes malabsorption and diarrhea. Atomic force microscopy (AFM) has been widely used to study the topography and morphology of living cells. Visualizing soft and flexible structures such as microvilli on the apical surface of a live cell has been very challenging because the native microvilli structures are displaced and deformed by the interaction with the probe. PeakForce Tapping® is an AFM imaging mode, which allows reducing tip-sample interactions in time (microseconds) and controlling force in the low pico-Newton range. Data acquisition of this mode was optimized by using a newly developed PeakForce QNM-Live Cell probe, having a short cantilever with a 17-µm-long tip that minimizes hydrodynamic effects between the cantilever and the sample surface. In this paper, we have demonstrated for the first time the visualization of the microvilli on living kidney cells with AFM using PeakForce Tapping. The structures observed display a force dependence representing either the whole microvilli or just the tips of the microvilli layer. Together, PeakForce Tapping allows force control in the low pico-Newton range and enables the visualization of very soft and flexible structures on living cells under physiological conditions. © 2015 The Authors Journal of Molecular Recognition Published by John Wiley & Sons Ltd.

  5. Steady state of tapped granular polygons

    International Nuclear Information System (INIS)

    Carlevaro, Carlos M; Pugnaloni, Luis A

    2011-01-01

    The steady state packing fraction of a tapped granular bed is studied for different grain shapes via a discrete element method. Grains are monosized regular polygons, from triangles to icosagons. Comparisons with disc packings show that the steady state packing fraction as a function of the tapping intensity presents the same general trends in polygon packings. However, better packing fractions are obtained, as expected, for shapes that can tessellate the plane (triangles, squares and hexagons). In addition, we find a sharp transition for packings of polygons with more than 13 vertices signaled by a discontinuity in the packing fraction at a particular tapping intensity. Density fluctuations for most shapes are consistent with recent experimental findings in disc packing; however, a peculiar behavior is found for triangles and squares

  6. Wipe sampling for nicotine as a marker of thirdhand tobacco smoke contamination on surfaces in homes, cars, and hotels.

    Science.gov (United States)

    Quintana, Penelope J E; Matt, Georg E; Chatfield, Dale; Zakarian, Joy M; Fortmann, Addie L; Hoh, Eunha

    2013-09-01

    Secondhand smoke contains a mixture of pollutants that can persist in air, dust, and on surfaces for months or longer. This persistent residue is known as thirdhand smoke (THS). Here, we detail a simple method of wipe sampling for nicotine as a marker of accumulated THS on surfaces. We analyzed findings from 5 real-world studies to investigate the performance of wipe sampling for nicotine on surfaces in homes, cars, and hotels in relation to smoking behavior and smoking restrictions. The intraclass correlation coefficient for side-by-side samples was 0.91 (95% CI: 0.87-0.94). Wipe sampling for nicotine reliably distinguished between private homes, private cars, rental cars, and hotels with and without smoking bans and was significantly positively correlated with other measures of tobacco smoke contamination such as air and dust nicotine. The sensitivity and specificity of possible threshold values (0.1, 1, and 10 μg/m(2)) were evaluated for distinguishing between nonsmoking and smoking environments. Sensitivity was highest at a threshold of 0.1 μg/m(2), with 74%-100% of smoker environments showing nicotine levels above threshold. Specificity was highest at a threshold of 10 μg/m(2), with 81%-100% of nonsmoker environments showing nicotine levels below threshold. The optimal threshold will depend on the desired balance of sensitivity and specificity and on the types of smoking and nonsmoking environments. Surface wipe sampling for nicotine is a reliable, valid, and relatively simple collection method to quantify THS contamination on surfaces across a wide range of field settings and to distinguish between nonsmoking and smoking environments.

  7. False negative rate and other performance measures of a sponge-wipe surface sampling method for low contaminant concentrations.

    Energy Technology Data Exchange (ETDEWEB)

    Einfeld, Wayne; Krauter, Paula A.; Boucher, Raymond M.; Tezak, Mathew; Amidan, Brett G. (Pacific Northwest National Laboratory, Richland, WA); Piepel, Greg F. (Pacific Northwest National Laboratory, Richland, WA)

    2011-05-01

    Recovery of spores from environmental surfaces is known to vary due to sampling methodology, techniques, spore size and characteristics, surface materials, and environmental conditions. A series of tests were performed to evaluate a new, validated sponge-wipe method. Specific factors evaluated were the effects of contaminant concentrations and surface materials on recovery efficiency (RE), false negative rate (FNR), limit of detection (LOD) - and the uncertainties of these quantities. Ceramic tile and stainless steel had the highest mean RE values (48.9 and 48.1%, respectively). Faux leather, vinyl tile, and painted wood had mean RE values of 30.3, 25.6, and 25.5, respectively, while plastic had the lowest mean RE (9.8%). Results show a roughly linear dependence of surface roughness on RE, where the smoothest surfaces have the highest mean RE values. REs were not influenced by the low spore concentrations tested (3 x 10{sup -3} to 1.86 CFU/cm{sup 2}). The FNR data were consistent with RE data, showing a trend of smoother surfaces resulting in higher REs and lower FNRs. Stainless steel generally had the lowest mean FNR (0.123) and plastic had the highest mean FNR (0.479). The LOD{sub 90} varied with surface material, from 0.015 CFU/cm{sup 2} on stainless steel up to 0.039 on plastic. Selecting sampling locations on the basis of surface roughness and using roughness to interpret spore recovery data can improve sampling. Further, FNR values, calculated as a function of concentration and surface material, can be used pre-sampling to calculate the numbers of samples for statistical sampling plans with desired performance, and post-sampling to calculate the confidence in characterization and clearance decisions.

  8. Harvesting contaminants from liquid

    Science.gov (United States)

    Simpson, John T.; Hunter, Scott R.

    2016-05-31

    Disclosed are examples of apparatuses for evaporative purification of a contaminated liquid. In each example, there is a vessel for storing the contaminated fluid. The vessel includes a surface coated with a layer of superhydrophobic material and the surface is at least partially in contact with the contaminated liquid. The contaminants do not adhere to the surface as the purified liquid evaporates, thus allowing the contaminants to be harvested.

  9. Fluctuation of biological rhythm in finger tapping

    Science.gov (United States)

    Yoshinaga, H.; Miyazima, S.; Mitake, S.

    2000-06-01

    By analyzing biological rhythms obtained from finger tapping, we have investigated the differences of two biological rhythms between healthy and handicapped persons caused by Parkinson, brain infraction, car accident and so on. In this study, we have observed the motion of handedness of all subjects and obtained a slope a which characterizes a power-law relation between frequency and amplitude of finger-tapping rhythm. From our results, we have estimated that the slope a=0.06 is a rough criterion in order to distinguish healthy and handicapped persons.

  10. The Effect of Delayed Visual Feedback on Synchrony Perception in a Tapping Task

    Directory of Open Access Journals (Sweden)

    Mirjam Keetels

    2011-10-01

    Full Text Available Sensory events following a motor action are, within limits, interpreted as a causal consequence of those actions. For example, the clapping of the hands is initiated by the motor system, but subsequently visual, auditory, and tactile information is provided and processed. In the present study we examine the effect of temporal disturbances in this chain of motor-sensory events. Participants are instructed to tap a surface with their finger in synchrony with a chain of 20 sound clicks (ISI 750 ms. We examined the effect of additional visual information on this ‘tap-sound’-synchronization task. During tapping, subjects will see a video of their own tapping hand on a screen in front of them. The video can either be in synchrony with the tap (real-time recording, or can be slightly delayed (∼40–160 ms. In a control condition, no video is provided. We explore whether ‘tap-sound’ synchrony will be shifted as a function of the delayed visual feedback. Results will provide fundamental insights into how the brain preserves a causal interpretation of motor actions and their sensory consequences.

  11. A comparison of damage profiling of automated tap testers on aircraft CFRP panel

    Science.gov (United States)

    Mohd Aris, K. D.; Shariff, M. F.; Abd Latif, B. R.; Mohd Haris, M. Y.; Baidzawi, I. J.

    2017-12-01

    The use of composite materials nevertheless is getting more prominent. The combination of reinforcing fibers and matrices will produce the desired strength orientation, tailorability and not to mention the complex shape that is hard to form on metallic structure. The weight percentage of composite materials used in aerospace, civil, marine etc. has increased tremendously. Since composite are stacked together, the possibility of delamination and/disbond defects are highly present either in the monolithic or sandwich structures. Tap test is the cheapest form of nondestructive test to identify the presence of this damage. However, its inconsistency and wide area of coverage can reduce its effectivity since it is carried out manually. The indigenous automated tap tester known as KETOK was used to detect the damage due to trapped voids and air pockets. The mechanism of detection is through controlling the tapping on the surface automatically at a constant rate. Another manual tap tester RD-3 from Wichitech Industries Inc. was used as reference. The acquired data was translated into damage profiling and both results were compared. The results have shown that the indigenous automated tester can profile the damage better when compared with the existing tap tester. As a conclusion, the indigenous automated tap tester has a potential to be used as an IN-SITU damage detection tool to detect delamination and disbond damage on composite panel. However, more conclusive tests need to be done in order to make the unit available to conventional users.

  12. Functional analysis of the accessory protein TapA in Bacillus subtilis amyloid fiber assembly.

    Science.gov (United States)

    Romero, Diego; Vlamakis, Hera; Losick, Richard; Kolter, Roberto

    2014-04-01

    Bacillus subtilis biofilm formation relies on the assembly of a fibrous scaffold formed by the protein TasA. TasA polymerizes into highly stable fibers with biochemical and morphological features of functional amyloids. Previously, we showed that assembly of TasA fibers requires the auxiliary protein TapA. In this study, we investigated the roles of TapA sequences from the C-terminal and N-terminal ends and TapA cysteine residues in its ability to promote the assembly of TasA amyloid-like fibers. We found that the cysteine residues are not essential for the formation of TasA fibers, as their replacement by alanine residues resulted in only minor defects in biofilm formation. Mutating sequences in the C-terminal half had no effect on biofilm formation. However, we identified a sequence of 8 amino acids in the N terminus that is key for TasA fiber formation. Strains expressing TapA lacking these 8 residues were completely defective in biofilm formation. In addition, this TapA mutant protein exhibited a dominant negative effect on TasA fiber formation. Even in the presence of wild-type TapA, the mutant protein inhibited fiber assembly in vitro and delayed biofilm formation in vivo. We propose that this 8-residue sequence is crucial for the formation of amyloid-like fibers on the cell surface, perhaps by mediating the interaction between TapA or TapA and TasA molecules.

  13. Macro and microelements in bottled and tap waters of Serbia

    Directory of Open Access Journals (Sweden)

    Petrović Tanja M.

    2012-01-01

    Full Text Available Comparative analysis between bottled and tap waters as well as its comparison with current Serbian regulations, European Union Directives and World Health Organization standard are shown in this paper. Thirteen bottled waters and fourteen tap waters from the territory of Serbia were analyzed in the Federal Institute for Geosciences and Natural Resources (BGR laboratory in Berlin, for the purpose of the “Geochemistry of European Bottled Water“ project conducted by EuroGeo Survey Geochemistry (EGS. Macrocomponents (main cations and anions of ground waters usually reflect on lithogeochemistry of the aquifer, while microcomponents indicate the circulation of ground water through the different lithological environment. Analyzed bottled waters could be classified as those with low mineral content (M<500 mg/L if HCO3 anion and Ca and Mg cations were the prevailing ones, or mineral (M>500 mg/L with prevailing HCO3 anion and Na cation. Waters with low mineral content were mainly from limestone and dolomite, while mineral waters mainly originated from magmatic and metamorphic rocks. Higher content of Cs, Li, Ge, Rb and F in bottled waters indicates the importance of the magmatic intrusions influence on their chemical composition. In some waters higher content of B, I, NH4, as well as of Tl and W has been observed which can be attributed to water’s circulation through different lithological complexes. Tap water was mostly obtained from groundwater (from Neogen and alluvial aquifers and karst springs with rest being those of rivers and surface accumulations. Tap waters from Central Serbia were with low mineral content, with prevailing HCO3 anion and Ca and Mg cations, while waters from Vojvodina, the northern province of Serbia, were with higher mineralization, HCO3-Na. Chemical analyses of the sampled tap waters showed good quality, with exception of waters from the cities of Senta and Zrenjanin in Vojvodina. High values of B (1170 and 895 g/L, As

  14. Contamination of environmental surfaces by methicillin-resistant Staphylococcus aureus (MRSA) in rooms of inpatients with MRSA-positive body sites.

    Science.gov (United States)

    Kurashige, E Jessica Ohashi; Oie, Shigeharu; Furukawa, H

    2016-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) can contaminate environmental surfaces that are frequently touched by the hands of patients with MRSA colonization/infection. There have been many studies in which the presence or absence of MRSA contamination was determined but no studies in which MRSA contamination levels were also evaluated in detail. We evaluated MRSA contamination of environmental surfaces (overbed tables, bed side rails, and curtains) in the rooms of inpatients from whom MRSA was isolated via clinical specimens. We examined the curtains within 7-14 days after they had been newly hung. The environmental surfaces were wiped using gauze (molded gauze for wiping of surface bacteria; 100% cotton, 4cm×8cm) moistened with sterile physiological saline. The MRSA contamination rate and mean counts (range) were 25.0% (6/24 samples) and 30.6 (0-255)colony-forming units (cfu)/100cm(2), respectively, for the overbed tables and 31.6% (6/19 samples) and 159.5 (0-1620)cfu/100cm(2), respectively, for the bed side rails. No MRSA was detected in 24 curtain samples. The rate of MRSA contamination of environmental surfaces was high for the overbed tables and bed side rails but low for the curtains. Therefore, at least until the 14th day of use, frequent disinfection of curtains may be not necessary. Copyright © 2016. Published by Elsevier Editora Ltda.

  15. Perfluoroalkyl acids (PFAAs) in the Pra and Kakum River basins and associated tap water in Ghana.

    Science.gov (United States)

    Essumang, David K; Eshun, Albert; Hogarh, Jonathan N; Bentum, John K; Adjei, Joseph K; Negishi, Junya; Nakamichi, Shihori; Habibullah-Al-Mamun, Md; Masunaga, Shigeki

    2017-02-01

    Perfluoroalkyl acids (PFAAs) are persistent environmental pollutants that have been detected in various media including human serum. Due to concerns regarding their bioaccumulation and possible negative health effects, an understanding of routes of human exposure is necessary. PFAAs are recalcitrant in many water treatment processes, making drinking water a potential source of human exposure. This study presents the first report on contamination from PFAAs in river and drinking water in Ghana. The targeted PFAAs were perfluoroalkyl carboxylic acids (PFCAs) with C 4-14 carbon chain and perfluoroalkane sulphonic acids (PFSAs) with C 6, 8, 10 . Five PFAA congeners - PFOA, PFOS, PFHxA, PFDA and PFPeA - were commonly detected in river and tap water. The mean concentrations of ∑PFAAs in the Kakum and Pra Rivers were 281 and 398ng/L, while tap water (supplied from the treatment of water from those rivers) contained concentrations of 197 and 200ng/L, respectively. PFOA and PFOS constituted about 99% of the ∑PFAAs. The risk quotient (RQ) attributed to drinking of tap water was estimated at 1.01 and 1.74 for PFOA and PFOS, respectively. For a country that has not produced these compounds, the RQs were unexpectedly high, raising concerns particularly about contamination from such emerging pollutants in local water sources. The study revealed limitations of local tap water treatment in getting rid of these emerging pollutants. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Inserting the tap values of the tap changer transformers into the Jacobian matrix as control variables

    Directory of Open Access Journals (Sweden)

    Faruk Yalçın

    2013-06-01

    Full Text Available Series and shunt admittance values of under load tap changer transformers are changed according to tap changing. As this situation changes the structure of bus admittance matrix, it causes the need of rebuilding the bus admittance matrix at each tap changing case in power flow studies. In this paper, a new approach that includes the tap changing effects into the Jacobian matrix. By this approach, the need of rebuilding the bus admittance matrix at each tap changing case during power flow study is prevented. So, fast convergence is achieved for the power flow algorithm. Although there are similar studies for this aim in the literature, apart from these studies, including the tap changing effects to the Jacobian matrix when more than one under load tap changer transformers are connected to the same bus with different connection combinations is provided by the proposed approach. For this aim, new power equations and new Jacobian matrix component calculation equations are obtained. The proposed approach is tested on IEEE 57-bus test system and its accuracy is proved.

  17. [Disinfection with sodium hypochlorite in hospital environmental surfaces in the reduction of contamination and infection prevention: a systematic review].

    Science.gov (United States)

    Pereira, Samantha Storer Pesani; Oliveira, Hadelândia Milon de; Turrini, Ruth Natalia Teresa; Lacerda, Rúbia Aparecida

    2015-08-01

    To search for evidence of the efficiency of sodium hypochlorite on environmental surfaces in reducing contamination and prevention of healthcare-associated infection HAIs. Systematic review in accordance with the Cochrane Collaboration. We analyzed 14 studies, all controlled trials, published between 1989-2013. Most studies resulted in inhibition of microorganism growth. Some decreased infection, microorganism resistance and colonization, loss of efficiency in the presence of dirty and surface-dried viruses. The hypochlorite is an effective disinfectant, however, the issue of the direct relation with the reduction of HAIs remains. The absence of control for confounding variables in the analyzed studies made the meta-analysis performance inadequate. The evaluation of internal validity using CONSORT and TREND was not possible because its contents were not appropriate to laboratory and microbiological studies. As a result, there is an urgent need for developing specific protocol for evaluating such studies.

  18. Disinfection with sodium hypochlorite in hospital environmental surfaces in the reduction of contamination and infection prevention: a systematic review

    Directory of Open Access Journals (Sweden)

    Samantha Storer Pesani Pereira

    2015-08-01

    Full Text Available OBJECTIVETo search for evidence of the efficiency of sodium hypochlorite on environmental surfaces in reducing contamination and prevention of healthcare-associated infection HAIs.METHODSystematic review in accordance with the Cochrane Collaboration.RESULTSWe analyzed 14 studies, all controlled trials, published between 1989-2013. Most studies resulted in inhibition of microorganism growth. Some decreased infection, microorganism resistance and colonization, loss of efficiency in the presence of dirty and surface-dried viruses.CONCLUSIONThe hypochlorite is an effective disinfectant, however, the issue of the direct relation with the reduction of HAIs remains. The absence of control for confounding variables in the analyzed studies made the meta-analysis performance inadequate. The evaluation of internal validity using CONSORT and TREND was not possible because its contents were not appropriate to laboratory and microbiological studies. As a result, there is an urgent need for developing specific protocol for evaluating such studies.

  19. Reduction of bacterial surface contamination in the hospital environment by application of a new product with persistent effect.

    Science.gov (United States)

    Hedin, G; Rynbäck, J; Loré, B

    2010-06-01

    The benefit of routine surface disinfection in hospitals has been discussed. In this study we have investigated a new product, Appeartex. After application on surfaces a remnant effect is achieved due to the positive charge of the active molecule. We studied the persistent effect of Appeartex one day after application in both an experimental study in the laboratory and a field study in a hospital ward. Surfaces of bedside tables were investigated. In the experimental study, large inocula of >or=10(6)cfu of S. aureus or enterococci were inoculated on to well-defined areas which had been treated/not treated with Appeartex. One hour later, samples were taken with a swab rinse technique. A reduction in the number of viable bacteria in the magnitude 10-10(3) cfu was seen due to the effect of Appeartex. In the field study the effect on naturally occurring low level contamination was studied. Defined surfaces on bedside tables used by patients were treated/not treated with Appeartex. One day later, samples were taken with contact agar plates and with a new swab method using two sequential nylon flocked swabs. Significantly fewer bacteria were found on Appeartex-treated surfaces compared with untreated surfaces. The median counts on Appeartex-treated surfaces were 10 cfu/50 cm(2), and on untreated surfaces 20 cfu/50 cm(2). There was no significant difference in the number of bacteria found by culture of samples taken with the contact agar method compared with samples taken using the nylon flocked swab method. (c) 2010 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

  20. Influence of surface chemistry of carbon materials on their interactions with inorganic nitrogen contaminants in soil and water.

    Science.gov (United States)

    Sumaraj; Padhye, Lokesh P

    2017-10-01

    Inorganic nitrogen contaminants (INC) (NH 4 + , NO 3 - , NO 2 - , NH 3 , NO, NO 2 , and N 2 O) pose a growing risk to the environment, and their remediation methods are highly sought after. Application of carbon materials (CM), such as biochar and activated carbon, to remediate INC from agricultural fields and wastewater treatment plants has gained a significant interest since past few years. Understanding the role of surface chemistry of CM in adsorption of various INC is highly critical to increase adsorption efficiency as well as to assess the long term impact of using these highly recalcitrant CM for remediation of INC. Critical reviews of adsorption studies related to INC have revealed that carbon surface chemistry (surface functional groups, pH, Eh, elemental composition, and mineral content) has significant influence on adsorption of INC. Compared to basic functional groups, oxygen containing surface functional groups have been found to be more influential for adsorption of INC. However, basic sites on carbon materials still play an important role in chemisorption of anionic INC. Apart from surface functional groups, pH, Eh and pH zpc of CM and elemental and mineral composition of its surface are important properties capable of altering INC interactions with CM. This review summarizes our current understanding of INC interactions with CM's surface through the known chemisorption mechanisms: electrostatic interaction, hydrogen bonding, electron donor-acceptor mechanism, hydrophobic and hydrophilic interaction, chemisorption aided by minerals, and interactions influenced by pH and elemental composition. Change in surface chemistry of CM in soil during aging is also discussed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Clearance of surface-contaminated objects from the controlled area of a nuclear facility. Application of the SUDOQU methodology

    Energy Technology Data Exchange (ETDEWEB)

    Russo, F.; Mommaert, C. [Bel V, Brussels (Belgium); Dillen, T. van [National Institute for Public Health and the Environment (RIVM), Bilthoven (Netherlands)

    2018-01-15

    The lack of clearly defined surface-clearance levels in the Belgian regulation led Bel V to start a collaboration with the Dutch National Institute for Public Health and the Environment (RIVM) to evaluate the applicability of the SUDOQU methodology for the derivation of nuclide-specific surface-clearance criteria for objects released from nuclear facilities. SUDOQU is a methodology for the dose assessment of exposure to a surface-contaminated object, with the innovative assumption of a time-dependent surface activity whose evolution is influenced by removal and deposition mechanisms. In this work, calculations were performed to evaluate the annual effective dose resulting from the use of a typical office item, e.g. a bookcase. Preliminary results allow understanding the interdependencies between the model's underlying mechanisms, and show a strong sensitivity to the main input parameters. The results were benchmarked against those from a model described in Radiation Protection 101, to investigate the impact of the model's main assumptions. Results of the two models were in good agreement. The SUDOQU methodology appears to be a flexible and powerful tool, suitable for the proposed application. Therefore, the project will be extended to more generic study cases, to eventually develop surface-clearance levels applicable to objects leaving nuclear facilities.

  2. Recovery of phosphonate surface contaminants from glass using a simple vacuum extractor with a solid-phase microextraction fiber

    International Nuclear Information System (INIS)

    Groenewold, Gary S.; Scott, Jill R.; Rae, Catherine

    2011-01-01

    Graphical abstract: Highlights: → A field vacuum extractor (FVE) nondestructively samples surface-adsorbed organics. → The FVE creates a modest vacuum over the surface, volatilizing surface organics. → A solid phase microextraction fiber (SPME) collects volatilized organics. → The SPME is easily analyzed using GC/MS. → The FVE enables collection chemical signatures from hard-to-sample surfaces. - Abstract: Recovery of chemical contaminants from fixed surfaces for analysis can be challenging, particularly if it is not possible to acquire a solid sample to be taken to the laboratory. A simple device is described that collects semi-volatile organic compounds from fixed surfaces by creating an enclosed volume over the surface, then generating a modest vacuum. A solid-phase microextraction (SPME) fiber is then inserted into the evacuated volume where it functions to sorb volatilized organic contaminants. The device is based on a syringe modified with a seal that is used to create the vacuum, with a perforable plunger through which the SPME fiber is inserted. The reduced pressure speeds partitioning of the semi-volatile compounds into the gas phase and reduces the boundary layer around the SPME fiber, which enables a fraction of the volatilized organics to partition into the SPME fiber. After sample collection, the SPME fiber is analyzed using conventional gas chromatography/mass spectrometry. The methodology has been used to collect organophosphorus compounds from glass surfaces, to provide a simple test for the functionality of the devices. Thirty minute sampling times (ΔT vac ) resulted in fractional recovery efficiencies that ranged from 10 -3 to >10 -2 , and in absolute terms, collection of low nanograms was demonstrated. Fractional recovery values were positively correlated to the vapor pressure of the compounds being sampled. Fractional recovery also increased with increasing ΔT vac and displayed a roughly logarithmic profile, indicating that an

  3. Mathematical estimation of the level of microbial contamination on spacecraft surfaces by volumetric air sampling

    Science.gov (United States)

    Oxborrow, G. S.; Roark, A. L.; Fields, N. D.; Puleo, J. R.

    1974-01-01

    Microbiological sampling methods presently used for enumeration of microorganisms on spacecraft surfaces require contact with easily damaged components. Estimation of viable particles on surfaces using air sampling methods in conjunction with a mathematical model would be desirable. Parameters necessary for the mathematical model are the effect of angled surfaces on viable particle collection and the number of viable cells per viable particle. Deposition of viable particles on angled surfaces closely followed a cosine function, and the number of viable cells per viable particle was consistent with a Poisson distribution. Other parameters considered by the mathematical model included deposition rate and fractional removal per unit time. A close nonlinear correlation between volumetric air sampling and airborne fallout on surfaces was established with all fallout data points falling within the 95% confidence limits as determined by the mathematical model.

  4. Heavy metals and metalloids in the surface sediments of the Xiangjiang River, Hunan, China: distribution, contamination, and ecological risk assessment.

    Science.gov (United States)

    Chai, Liyuan; Li, Huan; Yang, Zhihui; Min, Xiaobo; Liao, Qi; Liu, Yi; Men, Shuhui; Yan, Yanan; Xu, Jixin

    2017-01-01

    Here, we aim to determine the distribution, ecological risk and sources of heavy metals and metalloids in the surface sediments of the Xiangjiang River, Hunan Province, China. Sixty-four surface sediment samples were collected in 16 sites of the Xiangjiang River, and the concentrations of ten heavy metals and metalloids (Mn, Zn, Cr, V, Pb, Cu, As, Ni, Co, and Cd) in the sediment samples were investigated using an inductively coupled plasma mass spectrometer (ICP-MS) and an atomic fluorescence spectrophotometer (AFS), respectively. The results showed that the mean concentrations of the ten heavy metals and metalloids in the sediment samples followed the order Mn > Zn > Cr > V > Pb > Cu > As ≈ Ni >Co > Cd. The geoaccumulation index (I geo ), enrichment factor (EF), modified degree of contamination (mC d ), and potential ecological risk index (RI) revealed that Cd, followed by Pb, Zn, and Cu, caused severely contaminated and posed very highly potential ecological risk in the Xiangjiang River, especially in Shuikoushan of Hengyang, Xiawan of Zhuzhou, and Yijiawan of Xiangtan. The Pearson's correlation coefficient (PCC) analysis, principal component analysis (PCA), and hierarchical cluster analysis (HCA) indicated that the ten heavy metals and metalloids in the sampling sediments of the Xiangjiang River were classified into three groups: (1) Cd, Pb, Zn, and Cu which possibly originated from Shuikoushan, Xiawan, and Yijiawan clustering Pb-Zn mining and smelting industries; (2) Co, V, Ni, Cr, and Al from natural resources; and (3) Mn and As. Therefore, our results suggest that anthropogenic activities, especially mining and smelting, have caused severe contamination of Cd, Pb, Zn, and Cu and posed very high potential ecological risk in the Xiangjiang River.

  5. Microbial activities and dissolved organic matter dynamics in oil-contaminated surface seawater from the Deepwater Horizon oil spill site.

    Science.gov (United States)

    Ziervogel, Kai; McKay, Luke; Rhodes, Benjamin; Osburn, Christopher L; Dickson-Brown, Jennifer; Arnosti, Carol; Teske, Andreas

    2012-01-01

    The Deepwater Horizon oil spill triggered a complex cascade of microbial responses that reshaped the dynamics of heterotrophic carbon degradation and the turnover of dissolved organic carbon (DOC) in oil contaminated waters. Our results from 21-day laboratory incubations in rotating glass bottles (roller bottles) demonstrate that microbial dynamics and carbon flux in oil-contaminated surface water sampled near the spill site two weeks after the onset of the blowout were greatly affected by activities of microbes associated with macroscopic oil aggregates. Roller bottles with oil-amended water showed rapid formation of oil aggregates that were similar in size and appearance compared to oil aggregates observed in surface waters near the spill site. Oil aggregates that formed in roller bottles were densely colonized by heterotrophic bacteria, exhibiting high rates of enzymatic activity (lipase hydrolysis) indicative of oil degradation. Ambient waters surrounding aggregates also showed enhanced microbial activities not directly associated with primary oil-degradation (β-glucosidase; peptidase), as well as a twofold increase in DOC. Concurrent changes in fluorescence properties of colored dissolved organic matter (CDOM) suggest an increase in oil-derived, aromatic hydrocarbons in the DOC pool. Thus our data indicate that oil aggregates mediate, by two distinct mechanisms, the transfer of hydrocarbons to the deep sea: a microbially-derived flux of oil-derived DOC from sinking oil aggregates into the ambient water column, and rapid sedimentation of the oil aggregates themselves, serving as vehicles for oily particulate matter as well as oil aggregate-associated microbial communities.

  6. Task 12: Laser cleaning of contaminated painted surfaces. Semi-annual report, April 1, 1996--September 30, 1996

    International Nuclear Information System (INIS)

    Grisanti, A.A.; Hassett, D.J.

    1997-01-01

    Paint contaminated with radionuclides and other hazardous materials is common in Department of Energy (DOE) facilities. Facility decommissioning and decontamination requires the removal of contaminated paint. Paint removal technologies include laser- and abrasive-based systems. F2 Associates are utilizing a pulsed-repetition CO 2 laser that produces a 2.5-cm x 2.5-cm beam which can be scanned across a 30- x 100-cm raster and, when placed on a robot, can be designed to clean any surface that the robot can be programmed to follow. Causing little or no damage to the substrate (concrete, steel, etc.), the laser ablates the material to be removed from a given surface. Ablated material is then pulled into a filtration and collection (VAC-PAC) system to prevent the hazardous substances from entering into the atmosphere. The VAC-PAC system deposits the ablated material into waste drums which may be removed from the system without compromising the integrity of the seal, allowing a new drum to be set up for collection without leakage of the ablated material into the atmosphere

  7. Response of monitors of surface contamination to internal exposition control from 131I in the 'nuclear medicine services'

    International Nuclear Information System (INIS)

    Puerta, Nancy; Rojo, Ana M.; Villella, Adrian; Gossio, Sebastian; Parada, Ines Gomez; Acosta, Norma; Arenas, German

    2013-01-01

    The IAEA, in its publication RS-G-1.2, proposes individual control of workers occupationally exposed with risk of internal exposure when the potential exposure provided by incorporation leads to a value of annual committed effective dose equal to or greater than 1 mSv. Because the radionuclide 131 I is the most important to control internal exposure in Nuclear Medicine Services, it is evaluated if the surface contamination monitors, commonly used in nuclear medicine centers of Argentina, would implement individual control of internal exposure to 131 I. Selected detectors were calibrated with a dummy neck and thyroid with calibrated sources of 131 I and 133 Ba reference. For each detector is was estimated the detection efficiency for 131 I and its detection limit. Each instrument was evaluated for the lowest effective dose possible to detect compromised by individual routine monitoring with different measurement intervals . We analyzed the response of each team for determining conditions that may be effective for the control of internal exposure of 131 I. Finally , we conclude that the daily individual monitoring surface contamination detectors available in the Nuclear Medicine Services is feasible to implement and ensures detection of significant additions of 131 I

  8. Heavy metal contamination of surface soil in electronic waste dismantling area: site investigation and source-apportionment analysis.

    Science.gov (United States)

    Jinhui Li; Huabo Duan; Pixing Shi

    2011-07-01

    The dismantling and disposal of electronic waste (e-waste) in developing countries is causing increasing concern because of its impacts on the environment and risks to human health. Heavy-metal concentrations in the surface soils of Guiyu (Guangdong Province, China) were monitored to determine the status of heavy-metal contamination on e-waste dismantling area with a more than 20 years history. Two metalloids and nine metals were selected for investigation. This paper also attempts to compare the data among a variety of e-waste dismantling areas, after reviewing a number of heavy-metal contamination-related studies in such areas in China over the past decade. In addition, source apportionment of heavy metal in the surface soil of these areas has been analysed. Both the MSW open-burning sites probably contained invaluable e-waste and abandoned sites formerly involved in informal recycling activities are the new sources of soil-based environmental pollution in Guiyu. Although printed circuit board waste is thought to be the main source of heavy-metal emissions during e-waste processing, requirement is necessary to soundly manage the plastic separated from e-waste, which mostly contains heavy metals and other toxic substances.

  9. Laser Cleaning of Contaminated Painted Surfaces. Semiannual report, November 1, 1996--March 31, 1997

    International Nuclear Information System (INIS)

    Grisanti, Ames A.; Jensen, Robert R.

    1997-01-01

    The objective of this project is to develop a software tool for use by personnel who must select a surface decontamination technique. The software will incorporate performance data for available surface decontamination techniques. The major activities in the project are broken down as follows: Task 1 - Complete decision tree development. Task 2 - Literature search for surface decontamination reports. Task 3 - Compilation of database from literature data. Task 4 - Sensitivity analysis and model design. Task 5 - Design of model data structures. Task 6 - PC software design and coding

  10. 10BASE5 Ethernet Cable & Vampire Tap

    CERN Document Server

    1983-01-01

    10BASE5 Thick Ethernet Cable, 10Mbit/sec. In the 1980s and early 1990's, Ethernet became more popular and provided a much faster data transmission rate. This cable is one of the first ethernet cables from 1983, a thick, bulky affair. Computers were attached via "Vampire Taps" which were connectors screwed straight through the shielding of the cable.

  11. Workshop on physics related to TAPS

    International Nuclear Information System (INIS)

    Kuehn, W.; Loehner, H.

    1991-06-01

    Since December 1989 there exist two accepted proposals for TAPS experiments at SIS: 'η production in Relativistic Heavy Ion Experiments' (S 025) and 'π 0 Excitation Function and π 0 -π 0 Correlations Combined with Charged Particle Flow Analysis' (S 042). A third proposal 'Electromagnetic Excitations' (S 046) was submitted and is accepted by now. Before the new phase with data taking and detailed analysis of relativistic heavy ion data was about to begin, it was feld that there should be a few days set aside to take breath and to consider in a relaxed atmosphere the physics goals for which TAPS was constructed. The large number of undergraduate and graduate students in the collaboration was additional good reason to plan a meeting in a workshop-like atmosphere in order to communicate recent experimental and theoretical results touching the goals of TAPS and to discuss the aims of the submitted proposals and methods of the respective data analysis. Moreover, new ideas for future proposals and advanced technical developments should also be discussed. The aim was to broaden the view for applications of TAPS for photon and neutral meson measurements at the different accelerators at GANIL(Caen), SIS(GSI), MAMI(Mainz) and AGOR(KVI). See hints under the relevant topics. (orig./HSI)

  12. Sinusitis from Nontuberculous Mycobacteria in Tap Water

    Centers for Disease Control (CDC) Podcasts

    2012-12-21

    Dr. Wellington S. Tichenor. Associate Clinical Professor of Medicine at New York Medical College and in private practice in Manhattan, New York, discusses his investigation of sinusitis from nontuberculous mycobacteria in tap water.  Created: 12/21/2012 by National Center for Emerging and Zoonotic Infectious Diseases (NCEZID).   Date Released: 12/31/2012.

  13. Ideomotor effects of pitch on continuation tapping.

    Science.gov (United States)

    Ammirante, Paolo; Thompson, William F; Russo, Frank A

    2011-02-01

    The ideomotor principle predicts that perception will modulate action where overlap exists between perceptual and motor representations of action. This effect is demonstrated with auditory stimuli. Previous perceptual evidence suggests that pitch contour and pitch distance in tone sequences may elicit tonal motion effects consistent with listeners' implicit awareness of the lawful dynamics of locomotive bodies. To examine modulating effects of perception on action, participants in a continuation tapping task produced a steady tempo. Auditory tones were triggered by each tap. Pitch contour randomly and persistently varied within trials. Pitch distance between successive tones varied between trials. Although participants were instructed to ignore them, tones systematically affected finger dynamics and timing. Where pitch contour implied positive acceleration, the following tap and the intertap interval (ITI) that it completed were faster. Where pitch contour implied negative acceleration, the following tap and the ITI that it completed were slower. Tempo was faster with greater pitch distance. Musical training did not predict the magnitude of these effects. There were no generalized effects on timing variability. Pitch contour findings demonstrate how tonal motion may elicit the spontaneous production of accents found in expressive music performance.

  14. The TAPS Pyramid: Where, Who and How?

    Science.gov (United States)

    Hopwood-Stephens, Isabel

    2018-01-01

    The TAPS pyramid was developed in late 2014 and has been available as a download on the Primary Science Teaching Trust (PSTT) website since August 2015. But where has it gone since then? Who is using it? And how is it being used in schools to change primary science assessment practice? This article attempts to answer these questions with data from…

  15. Study of heavy ion collisions with TAPS

    NARCIS (Netherlands)

    Löhner, H.

    The photon spectrometer TAPS is a versatile instrument to measure nuclear bremsstrahlung and neutral mesons via their gamma decay. The formation and evolution of compressed nuclear matter is studied in heavy ion collisions at relativistic energies by analyzing the yield and spectral distribution of

  16. A survey of Cr(VI) contamination of surface water in the proximity of ...

    African Journals Online (AJOL)

    2013-07-30

    Jul 30, 2013 ... In this study, Cr(VI) levels present in surface water within the vicinity of ferrochrome smelters located in .... flict in literature pertaining to the toxicity or carcinogenicity ..... Due to the potential human health risks associated with.

  17. Sorption of nonpolar aromatic contaminants by chlorosilane surface modified natural minerals.

    Science.gov (United States)

    Huttenloch, P; Roehl, K E; Czurda, K

    2001-11-01

    The efficacy of the surface modification of natural diatomite and zeolite material by chlorosilanes is demonstrated. Chlorosilanes used were trimethylchlorosilane (TMSCI), tert-butyldimethylchlorosilane (TBDMSCI), dimethyloctadecylchlorosilane (DMODSCI), and diphenyldichlorosilane (DPDSCI) possessing different headgroups and chemical properties. Silanol groups of the diatomite and zeolite were modified by chemical reaction with the chlorosilanes resulting in a stable covalent attachment of the organosilanes to the mineral surface. The alteration of surface properties of the modified material was proved by measurements of water adsorption capacity, total organic carbon (TOC) content, and thermoanalytical data. The surface modified material showed great stability even when exposed to extremes in ionic strength, pH, and to pure organic solvents. Sorption of toluene, o-xylene, and naphthalene from water was greatly enhanced by the surface modification compared to the untreated materials which showed no measurable sorption of these compounds. The enhanced sorption was dependent on the organic carbon content as well as on chemical characteristics of the chlorosilanes used. Batch sorption experiments showed that the phenyl headgroups of DPDSCI have the best affinity for aromatic compounds. Removal from an aqueous solution of 10 mg/L of naphthalene, o-xylene, and toluene was 71%, 60%, and 30% for surface modified diatomite and 51%, 30%, and 16% for modified clinoptilolite, respectively. Sorption data were well described by the Freundlich isotherm equation, which indicated physical adsorption onto the lipophilic surface rather than partitioning into the surface organic phase. The chlorosilane modified materials have an apparent potential for application in environmental technologies such as permeable reactive barriers (PRB) or wastewater treatment.

  18. Timing at peak force may be the hidden target controlled in continuation and synchronization tapping.

    Science.gov (United States)

    Du, Yue; Clark, Jane E; Whitall, Jill

    2017-05-01

    Timing control, such as producing movements at a given rate or synchronizing movements to an external event, has been studied through a finger-tapping task where timing is measured at the initial contact between finger and tapping surface or the point when a key is pressed. However, the point of peak force is after the time registered at the tapping surface and thus is a less obvious but still an important event during finger tapping. Here, we compared the time at initial contact with the time at peak force as participants tapped their finger on a force sensor at a given rate after the metronome was turned off (continuation task) or in synchrony with the metronome (sensorimotor synchronization task). We found that, in the continuation task, timing was comparably accurate between initial contact and peak force. These two timing events also exhibited similar trial-by-trial statistical dependence (i.e., lag-one autocorrelation). However, the central clock variability was lower at the peak force than the initial contact. In the synchronization task, timing control at peak force appeared to be less variable and more accurate than that at initial contact. In addition to lower central clock variability, the mean SE magnitude at peak force (SEP) was around zero while SE at initial contact (SEC) was negative. Although SEC and SEP demonstrated the same trial-by-trial statistical dependence, we found that participants adjusted the time of tapping to correct SEP, but not SEC, toward zero. These results suggest that timing at peak force is a meaningful target of timing control, particularly in synchronization tapping. This result may explain the fact that SE at initial contact is typically negative as widely observed in the preexisting literature.

  19. Inorganic chemical quality of European tap-water: 2. Geographical distribution

    International Nuclear Information System (INIS)

    Flem, B.; Reimann, C.; Birke, M.; Banks, D.; Filzmoser, P.; Frengstad, B.

    2015-01-01

    Highlights: • European scale comparison of tap water. • 579 tap water samples have been analyses for more than 60 parameters. • Chemical geographical distribution. • Water treatment processes. • Importance of geology on tap water quality. - Abstract: 579 tap water samples were collected at the European scale and analysed at a single laboratory for more than 60 parameters. This dataset is analysed here in terms of the spatial and national distribution of the analysed inorganic chemical parameters. The distribution of most parameters is controlled by various artificial and natural factors (land use, distribution network, water source and treatment, geographical location and geology). The distribution of nitrate can be interpreted in terms of land use and climate. Water treatment affects the distribution of phosphorus in tap water; especially the policy of adding phosphate to potable water in the UK to suppress plumbosolvency. The distribution of alkalinity, Ca, Mg, Sr and Li appears to reflect both water source (low in surface waters) and the geological contrast between base-poor crystalline rock terrains and carbonate rich sedimentary rock. The Scandinavian nations’ tap water shows the highest concentrations of most of the rare earth elements, probably reflecting their geological availability and mobility in low pH raw water sources. The distribution of fluoride, uranium and arsenic also appear to exhibit geological and source (groundwater versus surface water) controls. Hungary returns several high As results, which may reflect As-rich reducing groundwaters of the Pannonian basin. Much Estonian tap water reflects a very specific hydrochemical environment, namely Palaeozoic near-coastal aquifers, which yield deep, reducing or saline groundwater (possibly influenced by marine intrusion), enriched in Ba, B, Br − , Cl − , Eu, F − , I, Li, K, Mn and Na

  20. Contamination levels of human pharmaceutical compounds in French surface and drinking water.

    Science.gov (United States)

    Mompelat, S; Thomas, O; Le Bot, B

    2011-10-01

    The occurrence of 20 human pharmaceutical compounds and metabolites from 10 representative therapeutic classes was analysed from resource and drinking water in two catchment basins located in north-west France. 98 samples were analysed from 63 stations (surface water and drinking water produced from surface water). Of the 20 human pharmaceutical compounds selected, 16 were quantified in both the surface water and drinking water, with 22% of the values above the limit of quantification for surface water and 14% for drinking water). Psychostimulants, non-steroidal anti-inflammatory drugs, iodinated contrast media and anxiolytic drugs were the main therapeutic classes of human pharmaceutical compounds detected in the surface water and drinking water. The results for surface water were close to results from previous studies in spite of differences in prescription rates of human pharmaceutical compounds in different countries. The removal rate of human pharmaceutical compounds at 11 water treatment units was also determined. Only caffeine proved to be resistant to drinking water treatment processes (with a minimum rate of 5%). Other human pharmaceutical compounds seemed to be removed more efficiently (average elimination rate of over 50%) by adsorption onto activated carbon and oxidation/disinfection with ozone or chlorine (not taking account of the disinfection by-products). These results add to the increasing evidence of the occurrence of human pharmaceutical compounds in drinking water that may represent a threat to human beings exposed to a cocktail of human pharmaceutical compounds and related metabolites and by-products in drinking water.

  1. Fecal pollution source tracking toolbox for identification, evaluation and characterization of fecal contamination in receiving urban surface waters and groundwater.

    Science.gov (United States)

    Tran, Ngoc Han; Gin, Karina Yew-Hoong; Ngo, Huu Hao

    2015-12-15

    The quality of surface waters/groundwater of a geographical region can be affected by anthropogenic activities, land use patterns and fecal pollution sources from humans and animals. Therefore, the development of an efficient fecal pollution source tracking toolbox for identifying the origin of the fecal pollution sources in surface waters/groundwater is especially helpful for improving management efforts and remediation actions of water resources in a more cost-effective and efficient manner. This review summarizes the updated knowledge on the use of fecal pollution source tracking markers for detecting, evaluating and characterizing fecal pollution sources in receiving surface waters and groundwater. The suitability of using chemical markers (i.e. fecal sterols, fluorescent whitening agents, pharmaceuticals and personal care products, and artificial sweeteners) and/or microbial markers (e.g. F+RNA coliphages, enteric viruses, and host-specific anaerobic bacterial 16S rDNA genetic markers) for tracking fecal pollution sources in receiving water bodies is discussed. In addition, this review also provides a comprehensive approach, which is based on the detection ratios (DR), detection frequencies (DF), and fate of potential microbial and chemical markers. DR and DF are considered as the key criteria for selecting appropriate markers for identifying and evaluating the impacts of fecal contamination in surface waters/groundwater. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. MODELING THE ANOMALY OF SURFACE NUMBER DENSITIES OF GALAXIES ON THE GALACTIC EXTINCTION MAP DUE TO THEIR FIR EMISSION CONTAMINATION

    Energy Technology Data Exchange (ETDEWEB)

    Kashiwagi, Toshiya; Suto, Yasushi; Taruya, Atsushi; Yahata, Kazuhiro [Department of Physics, The University of Tokyo, Tokyo 113-0033 (Japan); Kayo, Issha [Department of Physics, Toho University, Funabashi, Chiba 274-8510 (Japan); Nishimichi, Takahiro, E-mail: kashiwagi@utap.phys.s.u-tokyo.ac.jp [Institute for the Physics and Mathematics of the Universe, University of Tokyo, Kashiwa, Chiba 277-8568 (Japan)

    2015-02-01

    The most widely used Galactic extinction map is constructed assuming that the observed far-infrared (FIR) fluxes come entirely from Galactic dust. According to the earlier suggestion by Yahata et al., we consider how FIR emission of galaxies affects the SFD map. We first compute the surface number density of Sloan Digital Sky Survey (SDSS) DR7 galaxies as a function of the r-band extinction, A {sub r,} {sub SFD}. We confirm that the surface densities of those galaxies positively correlate with A {sub r,} {sub SFD} for A {sub r,} {sub SFD} < 0.1, as first discovered by Yahata et al. for SDSS DR4 galaxies. Next we construct an analytical model to compute the surface density of galaxies, taking into account the contamination of their FIR emission. We adopt a log-normal probability distribution for the ratio of 100 μm and r-band luminosities of each galaxy, y ≡ (νL){sub 100} {sub μm}/(νL) {sub r}. Then we search for the mean and rms values of y that fit the observed anomaly, using the analytical model. The required values to reproduce the anomaly are roughly consistent with those measured from the stacking analysis of SDSS galaxies. Due to the limitation of our statistical modeling, we are not yet able to remove the FIR contamination of galaxies from the extinction map. Nevertheless, the agreement with the model prediction suggests that the FIR emission of galaxies is mainly responsible for the observed anomaly. Whereas the corresponding systematic error in the Galactic extinction map is 0.1-1 mmag, it is directly correlated with galaxy clustering and thus needs to be carefully examined in precision cosmology.

  3. Highly reusability surface loaded metal particles magnetic catalyst microspheres (MCM-MPs) for treatment of dye-contaminated water

    International Nuclear Information System (INIS)

    Liu, Ying; Zhang, Kun; Yin, Xiaoshuang; Yang, Wenzhong; Zhu, Hongjun

    2016-01-01

    The metal-deposited magnetic catalyst microspheres (MCM-MPs) were successfully synthesized by one facile, high yield and controllable approach. Here, the bare magnetic microspheres were firstly synthesized according to the solvothermal method. Then silica shell were coated on the surface of the magnetic microspheres via sol–gel method, and subsequently with surface modifying with amino in the purpose to form SiO_2–NH_2 shell. Thus, metal particles were easily adsorbed into the SiO_2–NH_2 shell and in-situ reduced by NaBH_4 solution. All the obtained products (MCM-Cu, MCM-Ag, MCM-Pd) which were monodisperse and constitutionally stable were exhibited high magnetization and excellent catalytic activity towards dyes solution reduction. The catalytic rate ratio of MCM-Pd: MCM-Cu: MCM-Ag could be 10:3:1. Besides, some special coordination compound Cu_2(OH)_3Br had been generated in the in-situ reduced process of MCM-Cu, which produced superior cyclical stability (>20 times) than that of MCM-Ag and MCM-Pd. In all, those highly reusability and great catalytic efficiency of MCM-MPs show promising and great potential for treatment of dye-contaminated water. - Graphical abstract: Surface loaded metal particles magnetic catalyst microspheres MCM-MPs for rapid decolorizing dye-contaminated water: Synthesis, characterization and possible mechanisms. - Highlights: • A simple and high yield synthetic method for fabricate multi MCM-MPs is proposed with adequately optimize. • The highest reusability of MCM-Cu is attribute to the coordination compounds Cu_2(OH)_3Br. • MCM-MPs show excellent catalytic properties under different situations for various dyes • The catalytic mechanism of MCM-MPs is presented.

  4. Highly reusability surface loaded metal particles magnetic catalyst microspheres (MCM-MPs) for treatment of dye-contaminated water

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Ying; Zhang, Kun, E-mail: kun4219@njtech.edu.cn; Yin, Xiaoshuang; Yang, Wenzhong; Zhu, Hongjun

    2016-04-01

    The metal-deposited magnetic catalyst microspheres (MCM-MPs) were successfully synthesized by one facile, high yield and controllable approach. Here, the bare magnetic microspheres were firstly synthesized according to the solvothermal method. Then silica shell were coated on the surface of the magnetic microspheres via sol–gel method, and subsequently with surface modifying with amino in the purpose to form SiO{sub 2}–NH{sub 2} shell. Thus, metal particles were easily adsorbed into the SiO{sub 2}–NH{sub 2} shell and in-situ reduced by NaBH{sub 4} solution. All the obtained products (MCM-Cu, MCM-Ag, MCM-Pd) which were monodisperse and constitutionally stable were exhibited high magnetization and excellent catalytic activity towards dyes solution reduction. The catalytic rate ratio of MCM-Pd: MCM-Cu: MCM-Ag could be 10:3:1. Besides, some special coordination compound Cu{sub 2}(OH){sub 3}Br had been generated in the in-situ reduced process of MCM-Cu, which produced superior cyclical stability (>20 times) than that of MCM-Ag and MCM-Pd. In all, those highly reusability and great catalytic efficiency of MCM-MPs show promising and great potential for treatment of dye-contaminated water. - Graphical abstract: Surface loaded metal particles magnetic catalyst microspheres MCM-MPs for rapid decolorizing dye-contaminated water: Synthesis, characterization and possible mechanisms. - Highlights: • A simple and high yield synthetic method for fabricate multi MCM-MPs is proposed with adequately optimize. • The highest reusability of MCM-Cu is attribute to the coordination compounds Cu{sub 2}(OH){sub 3}Br. • MCM-MPs show excellent catalytic properties under different situations for various dyes • The catalytic mechanism of MCM-MPs is presented.

  5. GWSCREEN: A semi-analytical model for assessment of the groundwater pathway from surface or buried contamination: Theory and user's manual

    International Nuclear Information System (INIS)

    Rood, A.S.

    1992-03-01

    GWSCREEN was developed for assessment of the groundwater pathway from leaching of radioactive and non radioactive substances from surface or buried sources. The code was designed for implementation in the Track 1 and Track 2 assessment of Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) sites identified as low probability hazard at the Idaho National Engineering Laboratory (DOE, 1991). The code calculates the limiting soil concentration such that regulatory contaminant levels in groundwater are not exceeded. The code uses a mass conservation approach to model three processes: Contaminant release from a source volume, contaminant transport in the unsaturated zone, and contaminant transport in the saturated zone. The source model considers the sorptive properties and solubility of the contaminant. Transport in the unsaturated zone is described by a plug flow model. Transport in the saturated zone is calculated with a semi-analytical solution to the advection dispersion equation for transient mass flux input

  6. GWSCREEN: A semi-analytical model for assessment of the groundwater pathway from surface or buried contamination: Theory and user's manual

    Energy Technology Data Exchange (ETDEWEB)

    Rood, A.S.

    1992-03-01

    GWSCREEN was developed for assessment of the groundwater pathway from leaching of radioactive and non radioactive substances from surface or buried sources. The code was designed for implementation in the Track 1 and Track 2 assessment of Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) sites identified as low probability hazard at the Idaho National Engineering Laboratory (DOE, 1991). The code calculates the limiting soil concentration such that regulatory contaminant levels in groundwater are not exceeded. The code uses a mass conservation approach to model three processes: Contaminant release from a source volume, contaminant transport in the unsaturated zone, and contaminant transport in the saturated zone. The source model considers the sorptive properties and solubility of the contaminant. Transport in the unsaturated zone is described by a plug flow model. Transport in the saturated zone is calculated with a semi-analytical solution to the advection dispersion equation for transient mass flux input.

  7. GWSCREEN: A semi-analytical model for assessment of the groundwater pathway from surface or buried contamination: Theory and user`s manual

    Energy Technology Data Exchange (ETDEWEB)

    Rood, A.S.

    1992-03-01

    GWSCREEN was developed for assessment of the groundwater pathway from leaching of radioactive and non radioactive substances from surface or buried sources. The code was designed for implementation in the Track 1 and Track 2 assessment of Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) sites identified as low probability hazard at the Idaho National Engineering Laboratory (DOE, 1991). The code calculates the limiting soil concentration such that regulatory contaminant levels in groundwater are not exceeded. The code uses a mass conservation approach to model three processes: Contaminant release from a source volume, contaminant transport in the unsaturated zone, and contaminant transport in the saturated zone. The source model considers the sorptive properties and solubility of the contaminant. Transport in the unsaturated zone is described by a plug flow model. Transport in the saturated zone is calculated with a semi-analytical solution to the advection dispersion equation for transient mass flux input.

  8. In-Situ Imaging and Quantification of Tritium Surface Contamination via Coherent Fiber Bundle

    International Nuclear Information System (INIS)

    Gentile, Charles A.; Parker, John J.; Zweben, Stewart J.

    2001-01-01

    Princeton Plasma Physics Laboratory (PPPL) has developed a method of imaging tritium on in-situ surfaces for the purpose of real-time data collection. This method expands upon a previous tritium imaging concept, also developed at PPPL. Enhancements include an objective lens coupled to the entry aperture of a coherent fiber optic (CFO) bundle, and a relay lens connecting the exit aperture of the fiber bundle to an intensifier tube and a charge-coupled device (CCD) camera. The system has been specifically fabricated for use in determining tritium concentrations on first wall materials. One potential complication associated with the development of D-T [deuterium-tritium] fueled fusion reactors is the deposition of tritium (i.e., co-deposited layer) on the surface of the primary wall of the vacuum vessel. It would be advantageous to implement a process to accurately determine tritium distribution on these inner surfaces. This fiber optic imaging device provides a highly practical method for determining the location, concentration, and activity of surface tritium deposition. In addition, it can be employed for detection of tritium ''hot-spots'' and ''hide-out'' regions present on the surfaces being imaged

  9. Tritium surface loading due to contamination of rainwater from atmospheric release at NAPS

    International Nuclear Information System (INIS)

    Sharma, L.N.; Dube, B.; Varakhedkar, V.K.

    2001-01-01

    Annual tritium (HTO) surface loading has been measured and calculated for the year 1998-99 within 0.8 km distance from 145m high stack of Narora Atomic Power Station (NAPS) at eight locations in different directions. The technique for measured values consists of the summation of product of tritium concentration (Bq/l) in daily rainfall samples and daily rainfall (mm) whereas that for calculated values having the use of prevailing meteorological conditions and average tritium release rate during a year. The ratios of measured and calculated values of tritium surface loading during the years 1998-99 are found to be in the range of 0.18 to 6.97. Tritium surface loading studies at NAPS reveal that a fraction 1.7E-03 of total annual tritium released through stack gets deposited on the surface due to washout / rainout of plume within 0.8 km radial distance from stack. The range of deposition velocity, V w (m.s - 1 ) i.e the ratio of annual tritium surface loading W(Bq.m - 2 . s - 1 ) and annual mean tritium concentration in air, χo(Bq.m - 3) at three locations for the years 1998-99 is found to be 5.59E-04 to 5.99E-03 ms - 1 . The average value for wet deposition velocity V bar w for NAPS site is estimated as 2.92E-03 m.s - 1. (author)

  10. Phosphate ions as inhibiting agents for copper corrosion in chlorinated tap water

    Energy Technology Data Exchange (ETDEWEB)

    Yohai, L. [División Electroquímica y Corrosión, INTEMA, CONICET, UNMdP, Juan B. Justo 4302, B7608FDQ Mar del Plata (Argentina); Schreiner, W.H. [Laboratório de Superfícies e Interfases, Departamento de Física, Universidade Federal do Paraná, 81531-990 Curitiba, PR (Brazil); Vázquez, M., E-mail: mvazquez@fi.mdp.edu.ar [División Electroquímica y Corrosión, INTEMA, CONICET, UNMdP, Juan B. Justo 4302, B7608FDQ Mar del Plata (Argentina); Valcarce, M.B. [División Electroquímica y Corrosión, INTEMA, CONICET, UNMdP, Juan B. Justo 4302, B7608FDQ Mar del Plata (Argentina)

    2013-05-15

    PO{sub 4}{sup 3−} ions as corrosion inhibitor were investigated on copper in tap water in the presence of NaClO. The inhibitor was evaluated by electrochemical techniques and weight loss tests. Raman spectroscopy and X-ray photoelectron spectroscopy were used to study the passive layer. In inhibited tap water, the passive layer is thick and compact if NaClO is present. Weight-loss tests showed the inhibition of uniform dissolution and no pitting attack. When adding NaClO, Cu{sub 3}(PO{sub 4}){sub 2} is incorporated to the passive film. Thus, phosphate ions are effective as inhibitors for copper in tap water, even when using high dosages of biocides. - Highlights: ► Changes in the copper corrosion after adding phosphate to tap water were analyzed. ► When NaClO and phosphates are present, Cu{sub 3}(PO{sub 4}){sub 2} participates of the surface film. ► In the absence of biocide the surface film contains a mixture of Cu{sub 2}O, CuO and Cu(OH){sub 2}. ► PO{sub 4}{sup 3−} is an effective inhibitor for Cu in tap water containing high NaClO dosages.

  11. Phosphate ions as inhibiting agents for copper corrosion in chlorinated tap water

    International Nuclear Information System (INIS)

    Yohai, L.; Schreiner, W.H.; Vázquez, M.; Valcarce, M.B.

    2013-01-01

    PO 4 3− ions as corrosion inhibitor were investigated on copper in tap water in the presence of NaClO. The inhibitor was evaluated by electrochemical techniques and weight loss tests. Raman spectroscopy and X-ray photoelectron spectroscopy were used to study the passive layer. In inhibited tap water, the passive layer is thick and compact if NaClO is present. Weight-loss tests showed the inhibition of uniform dissolution and no pitting attack. When adding NaClO, Cu 3 (PO 4 ) 2 is incorporated to the passive film. Thus, phosphate ions are effective as inhibitors for copper in tap water, even when using high dosages of biocides. - Highlights: ► Changes in the copper corrosion after adding phosphate to tap water were analyzed. ► When NaClO and phosphates are present, Cu 3 (PO 4 ) 2 participates of the surface film. ► In the absence of biocide the surface film contains a mixture of Cu 2 O, CuO and Cu(OH) 2 . ► PO 4 3− is an effective inhibitor for Cu in tap water containing high NaClO dosages

  12. Screening hydroxyapatite for cadmium and lead immobilization in aqueous solution and contaminated soil: The role of surface area.

    Science.gov (United States)

    Li, Hongying; Guo, Xisheng; Ye, Xinxin

    2017-02-01

    Hydroxyapatite (HAP) has been widely used to immobilize many cationic metals in water and soils. The specific reason why an increase in the surface area of HAP enhances cadmium (Cd) uptake, but has no effect on lead (Pb) uptake, is not clear. The aim of this study was to determine the factors causing the differences in sorption behavior between Cd and Pb by evaluating HAPs with different surface areas. We synthesized HAPs with two different surface areas, which were characterized by X-ray diffraction, N 2 adsorption, and scanning electron microscopy, and then evaluated them as sorbents for Cd and Pb removal by testing in single and binary systems. The sorption capacity of large surface area HAP (1.85mmol/g) for Cd in the single-metal system was higher than that of small surface area HAP (0.64mmol/g), but there were no differences between single- and binary-metal solutions containing Pb. After the Cd experiments, the HAP retained a stable structure and intact morphology, which promotes the accessibility of reactive sites for Cd. However, a newly formed precipitate covered the surface and blocked the channels in the presence of Pb, which reduced the number of potential adsorption sites on HAP for Cd and Pb. Remediation experiments using Cd- and Pb-contaminated soil produced similar results to the solution tests. These results indicate that alterations of the structure and morphology during the reaction is an important factor influencing metal sorption to HAP. Copyright © 2016. Published by Elsevier B.V.

  13. No contaminant methods for the bio films formation control on metallic surfaces of industrial interest

    International Nuclear Information System (INIS)

    Gomez de Saravia, S. G.; Guiamet, P. S.

    2003-01-01

    The aim of this paper was the control of aerobic and anaerobic bacterial biofilms formation on metal surfaces of industrial interest such as stainless steel and mild steel. A natural biocida obtained of an aqueous extract of seeds of black mustard (Brassica nigra) and mixtures of immunoglobulins IgA, IgG, and IgM were used. Microscopic techniques like scanning electron microscopy (SEM) and epifluorescens microscopy were used for observing bacterial adhesion of the metal surfaces. A marked inhibition of bacterial adherence was observed when an immunoglobulin film was formed on the metal surface. When the natural biocide was used, an important decrease in the number of microorganisms in the biofilms was observed. (Author) 8 refs

  14. Residence time of contaminants released in surface coal mines -- a wind-tunnel study

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, R.S. [Environmental Protection Agency, Research Triangle Park, NC (United States)

    1994-12-31

    Surface coal mining operations (blasting, shoveling, loading, trucking, etc.) are sources of airborne particles. The 1990 Clean Air Act Amendments direct the EPA to analyze the accuracy of the Industrial Source Complex model and the AP-42 emission factors, and to make revisions as may be necessary to eliminate any significant over-prediction of air concentration of fugitive particles from surface coal mines. A wind-tunnel study was performed at the US EPA`s Fluid Modeling Facility to investigate dispersion from surface coal mines in support of the dispersion modeling activities. Described here is the portion of the study directed at determining the residence time that material released near the floor of a mine will stay within the mine.

  15. Insect Residue Contamination on Wing Leading Edge Surfaces: A Materials Investigation for Mitigation

    Science.gov (United States)

    Lorenzi, Tyler M.; Wohl, Christopher J.; Penner, Ronald K.; Smith, Joseph G.; Siochi, Emilie J.

    2011-01-01

    Flight tests have shown that residue from insect strikes on aircraft wing leading edge surfaces may induce localized transition of laminar to turbulent flow. The highest density of insect populations have been observed between ground level and 153 m during light winds (2.6 -- 5.1 m/s), high humidity, and temperatures from 21 -- 29 C. At a critical residue height, dependent on the airfoil and Reynolds number, boundary layer transition from laminar to turbulent results in increased drag and fuel consumption. Although this represents a minimal increase in fuel burn for conventional transport aircraft, future aircraft designs will rely on maintaining laminar flow across a larger portion of wing surfaces to reduce fuel burn during cruise. Thus, insect residue adhesion mitigation is most critical during takeoff and initial climb to maintain laminar flow in fuel-efficient aircraft configurations. Several exterior treatments investigated to mitigate insect residue buildup (e.g., paper, scrapers, surfactants, flexible surfaces) have shown potential; however, implementation has proven to be impractical. Current research is focused on evaluation of wing leading edge surface coatings that may reduce insect residue adhesion. Initial work under NASA's Environmentally Responsible Aviation Program focused on evaluation of several commercially available products (commercial off-the-shelf, COTS), polymers, and substituted alkoxy silanes that were applied to aluminum (Al) substrates. Surface energies of these coatings were determined from contact angle data and were correlated to residual insect excrescence on coated aluminum substrates using a custom-built "bug gun." Quantification of insect excrescence surface coverage was evaluated by a series of digital photographic image processing techniques.

  16. Chapter 13. Industrial Application of Tap Water Hydraulic Systems

    DEFF Research Database (Denmark)

    Conrad, Finn; Adelstorp, Anders

    1997-01-01

    Design and application of modern pure tap water components and systems in industries, in particular food processing industry.......Design and application of modern pure tap water components and systems in industries, in particular food processing industry....

  17. Chapter 12. Pure Tap Water Hydraulic Systems and Applications

    DEFF Research Database (Denmark)

    Conrad, Finn; Adelstorp, Anders

    1997-01-01

    Presentation of developed a modern pure tap water hydraulic components (Nessie), systems and industrial applications.......Presentation of developed a modern pure tap water hydraulic components (Nessie), systems and industrial