WorldWideScience

Sample records for surface contamination levels

  1. Automatic Measurement of Low Level Contamination on Concrete Surfaces

    International Nuclear Information System (INIS)

    Tachibana, M.; Itoh, H.; Shimada, T.; Yanagihara, S.

    2002-01-01

    Automatic measurement of radioactivity is necessary for considering cost effectiveness in final radiological survey of building structures in decommissioning nuclear facilities. The RAPID (radiation measuring pilot device for surface contamination) was developed to be applied to automatic measurement of low level contamination on concrete surfaces. The RAPID has a capability to measure contamination with detection limit of 0.14 Bq/cm2 for 60Co in 30 seconds of measurement time and its efficiency is evaluated to be 5 m2/h in a normal measurement option. It was confirmed that low level contamination on concrete surfaces could be surveyed by the RAPID efficiently compared with direct measurement by workers through its actual application

  2. Experimental study on source efficiencies for estimating surface contamination level

    International Nuclear Information System (INIS)

    Ichiji, Takeshi; Ogino, Haruyuki

    2008-01-01

    Source efficiency was measured experimentally for various materials, such as metals, nonmetals, flooring materials, sheet materials and other materials, contaminated by alpha and beta emitter radioactive nuclides. Five nuclides, 147 Pm, 60 Co, 137 Cs, 204 Tl and 90 Sr- 90 Y, were used as the beta emitters, and one nuclide 241 Am was used as the alpha emitter. The test samples were prepared by placing drops of the radioactive standardized solutions uniformly on the various materials using an automatic quantitative dispenser system from Musashi Engineering, Inc. After placing drops of the radioactive standardized solutions, the test materials were allowed to dry for more than 12 hours in a draft chamber with a hood. The radioactivity of each test material was about 30 Bq. Beta rays or alpha rays from the test materials were measured with a 2-pi gas flow proportional counter from Aloka Co., Ltd. The source efficiencies of the metals, nonmetals and sheet materials were higher than 0.5 in the case of contamination by the 137 Cs, 204 Tl and 90 Sr- 90 Y radioactive standardized solutions, higher than 0.4 in the case of contamination by the 60 Co radioactive standardized solution, and higher than 0.25 in the case of contamination by the alpha emitter the 241 Am radioactive standardized solution. These values were higher than those given in Japanese Industrial Standards (JIS) documents. In contrast, the source efficiencies of some permeable materials were lower than those given in JIS documents, because source efficiency varies depending on whether the materials or radioactive sources are wet or dry. This study provides basic data on source efficiency, which is useful for estimating the surface contamination level of materials. (author)

  3. Assessment of surface contamination level in an operating uranium ore processing facility of Jaduguda, India

    International Nuclear Information System (INIS)

    Meena, J.S.; Patnaik, R.L.; Jha, V.N.; Sahoo, S.K.; Ravi, P.M.; Tripathi, R.M.

    2014-01-01

    Radiological concern of the occupational workers and the area is given priority over other safety issue in confirmation with the stipulated guideline of national regulatory agency (AERB/FEFCF/SG-2, 2007). The key concern from the radiological hazard evaluation point of view is air activity, external gamma level and surface contamination. Present investigations was carried out to ascertain the surface contamination level of uranium ore processing facility at Jaduguda, Jharkhand. For a low grade uranium ore processing industry surface contamination is a major concern in product precipitation and recovery section. In view of this, the ore processing plant can broadly be classified into three areas i.e. ion exchange area, precipitation and product recovery section and other areas. The monitoring results incorporate the level of surface contamination of the plant during the last five years. The geometric mean activity of surface contamination level was 31.1, 34.5 and 9.8 Bq dm -2 in ion exchange, product precipitation and recovery and other areas with GSD of 2, 2.5 and 1.9. In most of the cases the surface contamination level was well within the recommended limit of 100 Bq dm -2 for M class uranium compound. Occasional cases of surface contamination levels exceeding the recommended limit were addressed and areas were decontaminated. Based on the study, modification in the design feature of the surface of the finished product section was also suggested so that the decontamination procedure can be more effectively implemented

  4. Levels of surface contamination with radioactive materials at workplaces of nuclear research centre at Rez

    International Nuclear Information System (INIS)

    Hoelgye, Z.; Nemcova, I.; Kasikova, M.; Popper, J.; Chysky, J.

    1983-01-01

    A hygiene supervision unit at workplaces of the nuclear Research Institute in Rez monitored on a long-term basis surface contamination with radioactive substances. Surface contamination was found at workplaces with open sources. Of the 4343 monitored places action levels were only exceeded in 13 cases. The obtained data were used for typifying workplaces with the highest level of surface contamination, to determine in certain instances the mechanism of the escape of radioactive substances from insulating facilities and to determine the rate of the spread of the radioactive substance into adjacent non-active workplaces. (author)

  5. Calculation of reasonable exemption levels for surface contamination by measuring overall gamma ray

    International Nuclear Information System (INIS)

    Ogino, Haruyuki; Hattori, Takatoshi

    2008-01-01

    The present regulation on surface contamination [Bq/cm 2 ] is determined from a simple radiological model for the most hazardous radionuclides (Pu-239 for alpha emitters and Sr-90 for beta emitters) and its extremely conservative model is applied for all other alpha and beta emitters. In this study, reasonable exemption levels for surface contamination are calculated for each radionuclide by adopting an original radiological dose evaluation method for surface contamination that can be applied in radiation safety, transport safety and waste safety. Furthermore, a new concept of judging the exemption by estimating the overall contamination [Bq] on the objects from the measurement of gamma ray has been designed and a reasonable value was derived. We conclude that the overall exemption levels obtained by gamma ray measurement can be one order smaller than those obtained by the conventional method for some radionuclides, such as Mn-54, Co-60, Nb-94, Cs-134, Cs-137, Eu-152 and Eu-154. (author)

  6. Fluorescence Imaging Reveals Surface Contamination

    Science.gov (United States)

    Schirato, Richard; Polichar, Raulf

    1992-01-01

    In technique to detect surface contamination, object inspected illuminated by ultraviolet light to make contaminants fluoresce; low-light-level video camera views fluorescence. Image-processing techniques quantify distribution of contaminants. If fluorescence of material expected to contaminate surface is not intense, tagged with low concentration of dye.

  7. Radioactive surface contamination monitors

    International Nuclear Information System (INIS)

    Aoyama, Kei; Minagoshi, Atsushi; Hasegawa, Toru

    1994-01-01

    To reduce radiation exposure and prevent contamination from spreading, each nuclear power plant has established a radiation controlled area. People and articles out of the controlled area are checked for the surface contamination of radioactive materials with surface contamination monitors. Fuji Electric has repeatedly improved these monitors on the basis of user's needs. This paper outlines typical of a surface contamination monitor, a personal surface contamination monitor, an article surface contamination monitor and a laundry monitor, and the whole-body counter of an internal contamination monitor. (author)

  8. Molecular-level removal of proteinaceous contamination from model surfaces and biomedical device materials by air plasma treatment.

    Science.gov (United States)

    Banerjee, K K; Kumar, S; Bremmell, K E; Griesser, H J

    2010-11-01

    Established methods for cleaning and sterilising biomedical devices may achieve removal of bioburden only at the macroscopic level while leaving behind molecular levels of contamination (mainly proteinaceous). This is of particular concern if the residue might contain prions. We investigated at the molecular level the removal of model and real-life proteinaceous contamination from model and practical surfaces by air plasma (ionised air) treatment. The surface-sensitive technique of X-ray photoelectron spectroscopy (XPS) was used to assess the removal of proteinaceous contamination, with the nitrogen (N1s) photoelectron signal as its marker. Model proteinaceous contamination (bovine serum albumin) adsorbed on to a model surface (silicon wafer) and the residual proteinaceous contamination resulting from incubating surgical stainless steel (a practical biomaterial) in whole human blood exhibited strong N1s signals [16.8 and 18.5 atomic percent (at.%), respectively] after thorough washing. After 5min air plasma treatment, XPS detected no nitrogen on the sample surfaces, indicating complete removal of proteinaceous contamination, down to the estimated XPS detection limit 10ng/cm(2). Applying the same plasma treatment, the 7.7at.% nitrogen observed on a clinically cleaned dental bur was reduced to a level reflective of new, as-received burs. Contact angle measurements and atomic force microscopy also indicated complete molecular-level removal of the proteinaceous contamination upon air plasma treatment. This study demonstrates the effectiveness of air plasma treatment for removing proteinaceous contamination from both model and practical surfaces and offers a method for ensuring that no molecular residual contamination such as prions is transferred upon re-use of surgical and dental instruments. Crown Copyright © 2010. Published by Elsevier Ltd. All rights reserved.

  9. Surface soil contamination standards

    International Nuclear Information System (INIS)

    Boothe, G.F.

    1979-01-01

    The purpose of this document is to define surface soil contamination limits for radioactive materials below which posting, restrictions and environmental controls are not necessary in order to protect personnel and the environment. The standards can also be used to determine if solid waste or other material is contaminated relative to disposal requirements. The derivation of the standards is given

  10. Contamination problems from glass beaker inner surface in low level Po-210 analysis

    Czech Academy of Sciences Publication Activity Database

    Kameník, Jan; Hölgye, Z.

    2010-01-01

    Roč. 283, č. 2 (2010), s. 493-495 ISSN 0236-5731 Institutional research plan: CEZ:AV0Z10480505 Keywords : Po-210 * Low-level analysis * Contamination Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 0.777, year: 2010

  11. Surface contamination technology in decommissioning of nuclear fuel cycle

    International Nuclear Information System (INIS)

    Ishiguro, Hideharu

    2012-01-01

    Surface contamination measurement is the most basic technology in radiation control of the nuclear and radiation facilities. Loose surface contamination causes internal exposure through airborne contamination. Surface contamination measurement is recently more important in the waste management such as confirmation of decontamination factor, contamination survey of carried-out materials from radioactive control area, and application of clearance level. This report describes the base of surface contamination standards, meaning of contamination in decommissioning, relationship between clearance level and surface contamination, and current technology of surface contamination measurement. (author)

  12. Mathematical estimation of the level of microbial contamination on spacecraft surfaces by volumetric air sampling

    Science.gov (United States)

    Oxborrow, G. S.; Roark, A. L.; Fields, N. D.; Puleo, J. R.

    1974-01-01

    Microbiological sampling methods presently used for enumeration of microorganisms on spacecraft surfaces require contact with easily damaged components. Estimation of viable particles on surfaces using air sampling methods in conjunction with a mathematical model would be desirable. Parameters necessary for the mathematical model are the effect of angled surfaces on viable particle collection and the number of viable cells per viable particle. Deposition of viable particles on angled surfaces closely followed a cosine function, and the number of viable cells per viable particle was consistent with a Poisson distribution. Other parameters considered by the mathematical model included deposition rate and fractional removal per unit time. A close nonlinear correlation between volumetric air sampling and airborne fallout on surfaces was established with all fallout data points falling within the 95% confidence limits as determined by the mathematical model.

  13. Contamination levels of human pharmaceutical compounds in French surface and drinking water.

    Science.gov (United States)

    Mompelat, S; Thomas, O; Le Bot, B

    2011-10-01

    The occurrence of 20 human pharmaceutical compounds and metabolites from 10 representative therapeutic classes was analysed from resource and drinking water in two catchment basins located in north-west France. 98 samples were analysed from 63 stations (surface water and drinking water produced from surface water). Of the 20 human pharmaceutical compounds selected, 16 were quantified in both the surface water and drinking water, with 22% of the values above the limit of quantification for surface water and 14% for drinking water). Psychostimulants, non-steroidal anti-inflammatory drugs, iodinated contrast media and anxiolytic drugs were the main therapeutic classes of human pharmaceutical compounds detected in the surface water and drinking water. The results for surface water were close to results from previous studies in spite of differences in prescription rates of human pharmaceutical compounds in different countries. The removal rate of human pharmaceutical compounds at 11 water treatment units was also determined. Only caffeine proved to be resistant to drinking water treatment processes (with a minimum rate of 5%). Other human pharmaceutical compounds seemed to be removed more efficiently (average elimination rate of over 50%) by adsorption onto activated carbon and oxidation/disinfection with ozone or chlorine (not taking account of the disinfection by-products). These results add to the increasing evidence of the occurrence of human pharmaceutical compounds in drinking water that may represent a threat to human beings exposed to a cocktail of human pharmaceutical compounds and related metabolites and by-products in drinking water.

  14. Redispersion of indoor surface contamination: a review

    International Nuclear Information System (INIS)

    Sansone, E.B.; Slein, M.W.

    1978-01-01

    The importance of surface contamination as a potential source of exposure to hazardous materials is discussed. Data from the literature concerning the resuspension of indoor surface contamination are presented. Reported procedures for quantitating surface contamination are compared. It is suggested that, despite its limitations, surface contamination monitoring may be useful in estimating potential risks from hazardous materials. (Auth.)

  15. Optical measurements on contaminated surfaces

    Science.gov (United States)

    Bonham, T. E.; Schmitt, R. J.; Linford, R. M. F.

    1975-01-01

    A bidirectional reflectometer system was developed for in situ measurements of the changes in spectral reflectance of surfaces contaminated with films of organic materials. The system permits experiments with films of controlled thickness in an environment that simulates the thermal, radiation, and vacuum conditions of space. The mechanical and optical construction of the reflectometer are discussed in detail, and actual data curves are used to illustrate its operation and performance.

  16. Hydrogen Contamination of Niobium Surfaces

    International Nuclear Information System (INIS)

    Viet Nguyen-Tuong; Lawrence Doolittle

    1993-01-01

    The presence of hydrogen is blamed for dramatic reductions in cavity Q's. Hydrogen concentration is difficult to measure, so there is a great deal of Fear, Uncertainty, and Doubt (FUD) associated with the problem. This paper presents measurements of hydrogen concentration depth profiles, commenting on the pitfalls of the methods used and exploring how material handling can change the amount of hydrogen in pieces of niobium. Hydrogen analysis was performed by a forward scattering experiment with Helium used as the primary beam. This technique is variously known as FRES (Forward Recoil Elastic Scattering), FRS, HFS (Hydrogen Forward Scattering), and HRA (Hydrogen Recoil Analysis). Some measurements were also made using SIMS (Secondary Ion Mass Spectrometry). Both HFS and SIMS are capable of measuring a depth profile of Hydrogen. The primary difficulty in interpreting the results from these techniques is the presence of a surface peak which is due (at least in part) to contamination with either water or hydrocarbons. With HFS, the depth resolution is about 30 nm, and the maximum depth profiled is about 300 nm. (This 10-1 ratio is unusually low for ion beam techniques, and is a consequence of the compromises that must be made in the geometry of the experiment, surface roughness, and energy straggling in the absorber foil that must be used to filter out the forward scattered helium.) All the observed HFS spectra include a surface peak which includes both surface contamination and any real hydrogen uptake by the niobium surface. Some contamination occurs during the analysis. The vacuum in the analysis chamber is typically a few times 10(sup -6) torr, and some of the contamination is in the form of hydrocarbons from the pumping system. Hydrocarbons normally form a very thin (less than a monolayer) film which is in equilibrium between arrival rate and the evaporation rate. In the presence of the incoming ion beam, however, these hydrocarbons crack on the surface into non

  17. Role of initial contamination levels, biofilm maturity and presence of salt and fat on desiccation survival of Listeria monocytogenes on stainless steel surfaces.

    Science.gov (United States)

    Hingston, Patricia A; Stea, Emma C; Knøchel, Susanne; Hansen, Truelstrup

    2013-10-01

    This study investigated the effect of initial contamination levels, biofilm maturity and presence of salt and fatty food soils on desiccation survival of Listeria monocytogenes on stainless steel (SS) coupons. L. monocytogenes cultures grown (at 15 °C for 48 h) in Tryptic Soy Broth with 1% glucose (TSB-glu) containing either 0.5 or 5% (w/v) NaCl were re-suspended in TSB-glu containing either 0.5 or 5% NaCl and used to contaminate SS coupons at levels of 3.5, 5.5, and 7.5 log CFU/cm². Desiccation (at 15 °C for 20 days, 43% RH) commenced immediately (non-biofilm) or following biofilm formation (at 15 °C for 48 h, 100% RH). To study the impact of food lipids, non-biofilm L. monocytogenes cells were suspended in TSB-glu containing either canola oil (5-10%) or lard (20-60%) and desiccated as above on SS coupons. Following desiccation for 20 days, survivors decreased by 1.4-3.7 log CFU/cm² for non-biofilm L. monocytogenes cells. The contamination level had no significant (p > 0.05) effect on survival kinetics. SEM micrographs showed mature biofilms on coupons initially contaminated with 5.5 and 7.5 log CFU/cm². Mature biofilm cells were significantly (p biofilms formed by the lowest contamination level. Besides biofilm maturity/formation, previous osmoadaptation, exposure to lard (20-60%) or salt (5%) during desiccation significantly (p biofilms and salty or fatty soils on food contact surfaces. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Some problems in calibrating surface contamination meters

    International Nuclear Information System (INIS)

    Chen Zigen; LI Xingyuan; Shuai Xiaoping.

    1984-01-01

    It is necessary that instruments are calibrated accurately in order to obtain reliable survey data of surface contamination. Some problems in calibrating surface contamination meters are expounded in this paper. Measurement comparison for beta surface contamination meters is organized within limited scope, thus survey quality is understood, questions are discovered, significance of calibration is expounded further. (Author)

  19. Contamination of optical surfaces in Earth orbit

    Science.gov (United States)

    Kinser, Donald L.; Weller, Robert A.; Mendenhall, M. H.; Wiedlocher, D. E.; Nichols, R.; Tucker, D.; Whitaker, A.

    1992-01-01

    Glass and glass ceramic samples exposed to the low earth orbit environment for approximately 5.5 years on the Long Duration Exposure Facility (LDEF) were found to display limited degradation in optical transmission. Commercial optical quality fused silica samples display decreases in transmission in the 200 to 400 nm wavelength region, and this degradation appears to be a consequence of surface contamination. The contamination, found only on internal surfaces of samples, was measured by medium energy backscattering spectrometry and found to be primarily carbon. Additional thin film contamination by a species with atomic mass near 64, which was present at the level of about 8 x 10 exp 14/sq. cm has not been identified. These observations are consistent with the interpretation that organic binders used in the black absorbing paint (Chem Glaze Z-306) inside the sample holding tray were concentrated in the vicinity of the samples and photolytically cracked by solar UV radiation. The resulting decomposition products were deposited on the interior sample surface and gave rise to the optical transmission loss. No detectable contamination was observed on the external or space exposed surface of the samples. No measurable damage was detected which could be attributed to the direct action of gamma or UV radiation on the glass samples. These results emphasize the need for special precautions in the preparation of spacecraft carrying precision optical components on long duration missions.

  20. Derived limits for surface contamination

    CERN Document Server

    Wrixon, A D; Linsley, G S; White, D F

    1979-01-01

    Derived limits (DLs) for surface contamination were first established for use in the nuclear energy industry where a wide variety of radionuclides is encountered. They were later used in factories, hospitals, and universities, where the radionuclides used are normally fewer in number, either known or readily identifiable, and often of low toxicity. In these situations the current limits are frequently over-restrictive. This report describes a reassessment of the values in the light of more recent information on the possible pathways of exposure and the dose equivalent limits given in ICRP Publication 26. The reassessment is prompted also by the introduction of SI units. The results of the reassessment are used to produce a classification of DLs for all radionuclides for active and inactive area surfaces and for skin.

  1. Airborne iodine-125 arising from surface contamination

    International Nuclear Information System (INIS)

    Kwok, C.S.; Hilditch, T.E.

    1982-01-01

    Measurements of airborne 125 I were made during the subdivision of 740 MBq stocks of 125 I iodide solution in a hospital dispensary. Within the fume cupboard the mean airborne 125 I concentration was 3.5 +- 2.9 kBqm -3 . No airborne concentration contamination was found outside the fume cupboard during these dispensing sessions. The airborne 125 I concentration arising from deliberate surface contamination (50 μl, 3.7-6.3 MBq) of the top of a lead pot was measured at a height simulating face level at an open work bench. There was a progressive fall in airborne concentration over seven days but even then the level was still significantly above background. Measurements made with the extraction system of the fume cupboard in operation were 2-3 times lower. (U.K.)

  2. Evaluation of Unfixed Tritium Surface Contamination

    International Nuclear Information System (INIS)

    Postolache, C.; Matei, Lidia

    2005-01-01

    Surface unfixed radioactive contamination represents the amount of surface total radioactive contamination which can be eliminated by pure mechanical processes. This unfixed contamination represents the main risk factor for contamination of the personnel which operates in tritium laboratories. Unfixed contamination was determined using sampling smears type FPCSN-PSE-AA. Those FPCSN-PSE-AA smears are disks of expanded polystyrene which contain acrylic acid fragments superficially grafted. Sampling factor was determinated by contaminated surface wiping with moisten smears in 50 μL butylic alcohol and activity measuring at liquid scintillation measuring device. Sampling factor was determined by the ratio between measured activity and initially real conventional activity. The sampling factor was determined for Tritium Laboratory existent surfaces: stainless steel, aluminum, glass, ceramics, linoleum, washable coats, epoxy resins type ALOREX LP-52.The sampling factors and the reproducibility were determined in function of surface nature

  3. Estimation of thyroid equivalent doses during evacuation based on body surface contamination levels in the nuclear accident of FDNPS in 2011

    Science.gov (United States)

    Ohba, Takashi; Hasegawa, Arifumi; Kohayakawa, Yoshitaka; Kondo, Hisayoshi; Suzuki, Gen

    2017-09-01

    To reduce uncertainty in thyroid dose estimation, residents' radiation protection behavior should be reflected in the estimation. Screening data of body surface contamination provide information on exposure levels during evacuation. Our purpose is to estimate thyroid equivalent doses based on body surface contamination levels using a new methodology. We obtained a record of 7,539 residents/evacuees. Geiger-Mueller survey meter measurement value in cpm was translated into Bq/cm2 according to the nuclides densities obtained by measuring clothing from two persons by germanium γ-spectrometer. The measurement value of body surface contamination on head was adjusted by a natural removal rate of 15 hours and radionuclides' physical half-life. Thyroid equivalent dose of 1-year-old children by inhalation was estimated by two-dimensional Monte Carlo simulation. The proportions of evacuees/residents with measurement value in cpm of Namie and Minamisoma groups were higher than those of other groups during both periods (p<0.01, Kruskal-Wallis). During 12-14 March period, 50 and 95 percentiles of thyroid equivalent doses by inhalation were estimated as 2.7 and 86.0 mSv, respectively, for Namie group, and 4.2 and 17.2 mSv, respectively, for Minamisoma group, 0.1 and 1.0 mSv, respectively, for Tomioka/Okuma/Futaba/Naraha group, and 0.2 and 2.1 mSv, respectively, for the other group. During 15- 17 March period, 50 and 95 percentiles of thyroid equivalent doses by inhalation were 0.8 and 15.7 mSv, respectively, for Namie group, and 1.6 and 8.4 mSv, respectively, for Minamisoma group, 0.2 and 13.2 mSv, respectively, for Tomioka/Okuma/Futaba/Naraha group, and 1.2 and 12.7 mSv, respectively, for the other group. It was indicated that inhalation dose was generally higher in Namie and Minamisoma groups during 12-14 March than those during 15-17 March might reflect different self-protective behavior to radioactive plumes from other groups.

  4. Organochlorine pesticides in surface soils from obsolete pesticide dumping ground in Hyderabad City, Pakistan: contamination levels and their potential for air-soil exchange.

    Science.gov (United States)

    Alamdar, Ambreen; Syed, Jabir Hussain; Malik, Riffat Naseem; Katsoyiannis, Athanasios; Liu, Junwen; Li, Jun; Zhang, Gan; Jones, Kevin C

    2014-02-01

    This study was conducted to examine organochlorine pesticides (OCPs) contamination levels in the surface soil and air samples together with air-soil exchange fluxes at an obsolete pesticide dumping ground and the associated areas from Hyderabad City, Pakistan. Among all the sampling sites, concentrations of OCPs in the soil and air samples were found highest in obsolete pesticide dumping ground, whereas dominant contaminants were dichlorodiphenyltrichloroethane (DDTs) (soil: 77-212,200 ng g(-1); air: 90,700 pg m(-3)) and hexachlorocyclohexane (HCHs) (soil: 43-4,090 ng g(-1); air: 97,400 pg m(-3)) followed by chlordane, heptachlor and hexachlorobenzene (HCB). OCPs diagnostic indicative ratios reflect historical use as well as fresh input in the study area. Moreover, the air and soil fugacity ratios (0.9-1.0) at the dumping ground reflecting a tendency towards net volatilization of OCPs, while at the other sampling sites, the fugacity ratios indicate in some cases deposition and in other cases volatilization. Elevated concentrations of DDTs and HCHs at pesticide dumping ground and its surroundings pose potential exposure risk to biological organisms, to the safety of agricultural products and to the human health. Our study thus emphasizes the need of spatio-temporal monitoring of OCPs at local and regional scale to assess and remediate the future adverse implications. © 2013.

  5. Removing high-level contaminants

    International Nuclear Information System (INIS)

    Wallace, Paula

    2013-01-01

    Full text: Using biomimicry, an Australian cleantech innovation making inroads intoChinas's industrial sector offers multiple benefits to miners and processors in Australia. Stephen Shelley, the executive chairman of Creative Water Technology (CWT), was on hand at a recent trade show to explain how his Melbourne company has developed world-class techniques in zero liquid discharge and fractional crystallization of minerals to apply to a wide range of water treatment and recycling applications. “Most existing technologies operate with high energy distillation, filters or biological processing. CWT's appliance uses a low temperature, thermal distillation process known as adiabatic recovery to desalinate, dewater and/or recycle highly saline and highly contaminated waste water,” said Shelley. The technology has been specifically designed to handle the high levels of contaminant that alternative technologies struggle to process, with proven water quality results for feed water samples with TDS levels over 300,000ppm converted to clean water with less than 20ppm. Comparatively, reverse osmosis struggles to process contaminant levels over 70,000ppm effectively. “CWT is able to reclaim up to 97% clean usable water and up to 100% of the contaminants contained in the feed water,” said Shelley, adding that soluble and insoluble contaminants are separately extracted and dried for sale or re-use. In industrial applications CWT has successfully processed feed water with contaminant levels over 650,000 mg/1- without the use of chemicals. “The technology would be suitable for companies in oil exploration and production, mining, smelting, biofuels, textiles and the agricultural and food production sectors,” said Shelley. When compared to a conventional desalination plant, the CWT system is able to capture the value in the brine that most plants discard, not only from the salt but the additional water it contains. “If you recover those two commodities... then you

  6. Drivers of contaminant levels in surface water of China during 2000-2030: Relative importance for illustrative home and personal care product chemicals.

    Science.gov (United States)

    Zhu, Ying; Price, Oliver R; Kilgallon, John; Qi, Yi; Tao, Shu; Jones, Kevin C; Sweetman, Andrew J

    2018-03-21

    Water pollution are among the most critical problems in China and emerging contaminants in surface water have attracted rising attentions in recent years. There is great interest in China's future environmental quality as the national government has committed to a major action plan to improve surface water quality. This study presents methodologies to rank the importance of socioeconomic and environmental drivers to the chemical concentration in surface water during 2000-2030. A case study is conducted on triclosan, a home and personal care product (HPCP) ingredient. Different economic and discharge flow scenarios are considered. Urbanization and wastewater treatment connection rates in rural and urban areas are collected or projected for 2000-2030 for counties across China. The estimated usage increases from ca. 86 to 340 t. However, emissions decreases from 76 to 52 t during 2000-2030 under a modelled Organisation for Economic Co-operation (OECD) economic scenario because of the urbanization, migration and development of wastewater treatment plants/facilities (WWTPs). The estimated national median concentration of triclosan ranges 1.5-8.2 ng/L during 2000-2030 for different scenarios. It peaks in 2009 under the OECD and three of the Intergovernmental Panel on Climate Change (IPCC), A2, B1 and B2 economic scenarios, but in 2025 under A1 economic scenario. Population distribution and surface water discharge flow rates are ranked as the top two drivers to triclosan levels in surface water over the 30 years. The development of urban WWTPs was the most important driver during 2000-2010 and the development of rural works is projected to be the most important in 2011-2030. Projections suggest discharges of ingredients in HPCPs - controlled by economic growth - should be balanced by the major expenditure programme on wastewater treatment in China. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Techniques for removing contaminated concrete surfaces

    International Nuclear Information System (INIS)

    Halter, J.M.; Sullivan, R.G.

    1981-01-01

    This discussion compares various techniques that have been used to clean concrete surfaces by removing the surface. Three techniques which have been investigated by the Pacific Northwest Laboratory for removing surfaces are also described: the water cannon, the concrete spaller, and high-pressure water jet. The equipment was developed with the assumption that removal of the top 1/8 to 1/4 in. of surface would remove most of the contamination. If the contamination has gone into cracks or deep voids in the surface, the removal processes can be repeated until the surface is acceptable

  8. Residual viral and bacterial contamination of surfaces after cleaning and disinfection

    NARCIS (Netherlands)

    Tuladhar, E.; Hazeleger, W.C.; Koopmans, M.; Zwietering, M.H.; Beumer, R.R.; Duizer, E.

    2012-01-01

    Environmental surfaces contaminated with pathogens can be sources of indirect transmission, and cleaning and disinfection are common interventions focused on reducing contamination levels. We determined the efficacy of cleaning and disinfection procedures for reducing contamination by noroviruses,

  9. Total effective dose equivalent associated with fixed uranium surface contamination

    International Nuclear Information System (INIS)

    Bogard, J.S.; Hamm, R.N.; Ashley, J.C.; Turner, J.E.; England, C.A.; Swenson, D.E.; Brown, K.S.

    1997-04-01

    This report provides the technical basis for establishing a uranium fixed-contamination action level, a fixed uranium surface contamination level exceeding the total radioactivity values of Appendix D of Title 10, Code of Federal Regulations, part 835 (10CFR835), but below which the monitoring, posting, and control requirements for Radiological Areas are not required for the area of the contamination. An area of fixed uranium contamination between 1,000 dpm/100 cm 2 and that level corresponding to an annual total effective dose equivalent (TEDE) of 100 mrem requires only routine monitoring, posting to alert personnel of the contamination, and administrative control. The more extensive requirements for monitoring, posting, and control designated by 10CFR835 for Radiological Areas do not have to be applied for these intermediate fixed-contamination levels

  10. Abnormal ''Contamination' Levels On Garden Appliances

    International Nuclear Information System (INIS)

    German, U.; Levinson, S.; Elmelech, V.; Pelled, O.; Tshuva, A.; Laichter, Y.

    1999-01-01

    During routine contamination checks we encountered an abnormal high level of Alpha and Beta emitting radioisotopes on working gloves of employees of the gardening department. It came out that the source was due to ''contamination'' levels on steering wheels of some gardening machines. In order to ensure that no real contamination of these workers was involved , a series of checks was started to identity the source of the abnormal levels found during monitoring

  11. BIOREMEDIATION OF CONTAMINATED SURFACE SOILS

    Science.gov (United States)

    Biological remediation of soils contaminated with organic chemicals is an alternative treatment technology that can often meet the goal of achieving a permanent clean-up remedy at hazardous waste sites, as encouraged by the U.S. Environmental Protection Agency (U.S. EPA) for impl...

  12. Calibration of alpha surface contamination monitor

    International Nuclear Information System (INIS)

    Freitas, I.S.M. de; Goncalez, O.L.

    1990-01-01

    In this work, the results, as well as the methodology, of the calibration of an alpha surface contamination monitor are presented. The calibration factors are obtained by least-squares fitting with effective variance. (author)

  13. Monitoring of surface and airborne contamination

    Energy Technology Data Exchange (ETDEWEB)

    Pradeep Kumar, K S [Bhabha Atomic Research Centre, Bombay (India)

    1997-06-01

    Indian nuclear energy programme aims at total safety in all activities involved in the entire fuel cycle for the occupational workers, members of the public and the environment as a whole. Routine radiation monitoring with clearly laid out procedures are followed for ensuring the safety of workers and public. Radiation monitoring carried out for the nuclear installations comprises of process monitoring, monitoring of effluent releases and also of the radiation protection monitoring of the individuals, work place and environment. Regulations like banning of smoking and consumption of food and drink etc. reduces the risk of direct ingestion even if inadvertent spread of contamination takes place. Though limit of transportable surface contamination is prescribed, the health physicists always follow a ``clean on swipe`` philosophy which compensates any error in the measurement of surface contamination. In this paper, the following items are contained: Necessity of contamination monitoring, accuracy required in the calibration of surface contamination monitors, methodology for contamination monitoring, air monitoring, guidelines for unrestricted release of scrap materials, and problems in contamination monitoring. (G.K.)

  14. Decontamination of radioactively contaminated surfaces

    International Nuclear Information System (INIS)

    1986-10-01

    By this standard objective conditions to evaluate and test the ease of decontamination of surfaces under laboratory conditions are to be laid down. Ease of decontamination in this context denotes the summed-up effect of two material properties: a) the capacity of the material for retaining radioactive substances at its surface; b) the ease with which these substances are given off again in the course of cleaning processes. (orig./HP) [de

  15. Development of radioactive surface contamination monitor

    International Nuclear Information System (INIS)

    Hashimoto, Tadao; Hasegawa, Toru; Fukumoto, Keisuke; Ooki, Yasushi

    2008-01-01

    In the radiation facilities such as nuclear power plants, surface contamination of the people accessing or articles conveyed in and out of the radiation controlled areas is detected and monitored by installing contamination monitors at the boundary of controlled areas and uncontrolled areas against the expansion of the radioactive materials to out of the facilities. It is required for the surface contamination of articles to be tightened of control criteria as 'Guidelines for discrimination ways of nonradioactive waste (not classified as radioactive waste) generated from nuclear power plants' (hereinafter referred to as 'the Guideline') was established by the Nuclear and Industrial Safety Agency of the Ministry of Economy, Trade and Industry in August, 2005. It predicts that the control criteria of monitors other than article monitors are also tightened in the future. Fuji electric has been fabricating and delivering surface contamination detecting monitors. Now we are developing the new contamination monitor corresponding to the tightening of the control criteria. 'Large article transfer monitor', 'Clothing monitor' and 'Body surface contamination monitor' are introduced in this article. (author)

  16. Occurrence of Surface Water Contaminations: An Overview

    Science.gov (United States)

    Shahabudin, M. M.; Musa, S.

    2018-04-01

    Water is a part of our life and needed by all organisms. As time goes by, the needs by human increased transforming water quality into bad conditions. Surface water contaminated in various ways which is pointed sources and non-pointed sources. Pointed sources means the source are distinguished from the source such from drains or factory but the non-pointed always occurred in mixed of elements of pollutants. This paper is reviewing the occurrence of the contaminations with effects that occurred around us. Pollutant factors from natural or anthropology factors such nutrients, pathogens, and chemical elements contributed to contaminations. Most of the effects from contaminated surface water contributed to the public health effects also to the environments.

  17. Quantification of surface contamination: principles and applications

    International Nuclear Information System (INIS)

    Vo-Dinh, T.

    1982-01-01

    The applications discussed in this paper underscore the usefulness and versatility of molecular luminescence spectroscopy as an efficient surface detection technique. The technique can be used not only as a qualitative characterization method, but also as a quantitative analytical tool to detect trace contaminants on surfaces. Recent advances in instrumentation and methodology have expanded the applicability of surface luminescence into many new problem areas. Trace organics are emphasized here

  18. Radiative Transfer Model for Contaminated Rough Surfaces

    Science.gov (United States)

    2013-02-01

    reflectance of potassium chlorate and ammonium nitrate contaminated surfaces in mid-wavelength and long-wavelength infrared for detection. Our framework...obtained excellent or good results for lab measurements of potassium chlorate on most aluminum surfaces; however, ammonium nitrate on painted aluminum...misidentify potassium chlorate as ammonium nitrate and vice versa). We also observed moderate success on field data. 15. SUBJECT TERMS radiative

  19. A consideration on internal dose evaluation and intervention based on a surface contamination concept

    International Nuclear Information System (INIS)

    Yasuda, H.

    1997-01-01

    Long-term radiation doses received by the inhabitants after the Chernobyl accident have been evaluated according to the surface contamination levels on the ground surface. The health effects have also been discussed by comparison between the surface-contaminated area and the uncontaminated control area. Selected protective measures were carried out in accordance with the contamination level of surface soil. These have been based on the 'surface contamination concept' which assumes that the radiation risk to inhabitants is proportional to the level of ground-surface contamination. The observations collected in regions around Chernobyl, however, show that the internal radiation doses to the inhabitants poorly correlate with the surface contamination level. This fact poses a question on the suitability of dose evaluations and interventions based on this concept

  20. Description of measurement techniques for surface contaminations

    International Nuclear Information System (INIS)

    Bourrez, E.

    2001-01-01

    The needs of evaluation of the surface contamination are numerous in the processes of production and management of radioactive waste. The market of radiation protection materials proposes a lot of devices answering to the almost all these needs. These device have however their conditions and particular limits for use. To realize correct measurements it is use the device, the technique and the methods adapted to the need, by taking into account the optimization of economical aspect. (N.C.)

  1. System for removing contaminated surface layers

    International Nuclear Information System (INIS)

    Yoshikawa, Kozo.

    1987-04-01

    The object of the present invention is to offer a new type of useful decontamination system, with which the contaminated surface layers can be removed effectively by injection of such solid microparticles. Liquid carbon dioxide is passed from a liquid carbon dioxide tank via the carbon dioxide supply line into the system for injecting solid carbon dioxide particles. Part of the liquid carbon dioxide introduced into the system is converted to solid carbon dioxide particles by the temperature drop resulting from adiabatic expansion in the carbon dioxide expansion space of the injection system. The solid carbon dioxide particles reach the injection nozzle, which is connected through the expansion space. The carbon dioxide microparticles are further cooled and accelerated by nitrogen gas injected from the nitrogen gas nozzle at the tip of the nitrogen gas supply line, which is connected to a liquid nitrogen tank. The cooled and accelerated solid carbon dioxide microparticles are injected from the injection nozzle for the solid carbon dioxide and directed against the contaminated surface to be cleaned, and, as a result, the surface contamination is removed

  2. Smears for determinations surface unfixed tritium contamination

    International Nuclear Information System (INIS)

    Postolache, Cristian; Matei, Lidia

    2003-01-01

    The present paper describes a method of obtaining expanded polystyrene with hydrophilized surface smears by radioinduced grafting of acrylic acid. The grafting was carried out by using a 60 Co γ radiation source. The variation of grafting rates as a function of dose range and absorbed dose was established. Grafting radiochemical rates were determined by radiometric methods using acrylic acid labeled with tritium as a grafting agent. The sampling coefficients and the reproducibility were analyzed as a function of the nature of the contaminated surface. (authors)

  3. Worker exposures from recycling surface contaminated radioactive scrap metal

    International Nuclear Information System (INIS)

    Kluk, A.; Phillips, J.W.; Culp, J.

    1996-01-01

    Current DOE policy permits release from DOE control of real property with residual levels of surficial radioactive contamination if the contamination is below approved guidelines. If the material contains contamination that is evenly distributed throughout its volume (referred to as volumetric contamination), then Departmental approval for release must be obtained in advance. Several DOE sites presently recycle surface contaminated metal, although the quantities are small relative to the quantities of metal processed by typical mini-mills, hence the potential radiation exposures to mill workers from processing DOE metals and the public from the processed metal are at present also a very small fraction of their potential value. The exposures calculated in this analysis are based on 100% of the scrap metal being processed at the maximum contamination levels and are therefore assumed to be maximum values and not likely to occur in actual practice. This paper examines the relationship between the surface contamination limits established under DOE Order 5400.5, open-quotes Radiation Protection of the Public and the Environment,close quotes and radiation exposures to workers involved in the scrap metal recycling process. The analysis is limited to surficial contamination at or below the guideline levels established in DOE Order 5400.5 at the time of release. Workers involved in the melting and subsequent fabrication of products are not considered radiation workers (no requirements for monitoring) and must be considered members of the public. The majority of the exposures calculated in this analysis range from tenths of a millirem per year (mrem/yr) to less than 5 mrem/yr. The incremental risk of cancer associated with these exposures ranges from 10 -8 cancers per year to 10 -6 cancers per year

  4. Assessment of arsenic surface contamination in a museum anthropology department.

    Science.gov (United States)

    Gribovich, Andrey; Lacey, Steven; Franke, John; Hinkamp, David

    2013-02-01

    To assess potential arsenic (As) contamination of work surfaces to improve upon the control strategy at an anthropology department in a large natural history museum. Work practices were observed and control strategy reviewed to inform an occupational hygiene assessment strategy utilizing surface wipe sampling. A total of 35 sampling targets were identified, focusing on surfaces that receive high touch traffic, including workstations, artifact transport carts, and elevator buttons. Arsenic sampling and analysis were performed using reference method Occupational Safety and Health Administration ID-125G. Four of the sampling areas returned detectable levels of As, ranging from 0.052 to 0.350 μg/100 cm. Workplace observations and wipe sampling data enabled the development of recommendations to help to further reduce potential occupational exposure to As. Continuous reduction of surface contamination is prudent for known human carcinogens.

  5. Contamination detector for inner surface of container

    International Nuclear Information System (INIS)

    Watanabe, Tadao.

    1995-01-01

    The present invention concerns a device for detecting contamination of radioactive materials on the inner surface of a vessel upon reutilizing the vessel for containing solidified radioactive wastes and transporting them. Namely, the detecting device has following functions. (1) A radiation detector detects the radioactive materials on the inner surface of the vessel. (2) A plurality of proximity switches measure the distance from the radiation detector to the wall surface of the vessel and are actuated if the distance is decreased to a predetermined value, (3) A vessel inner surface position calculation mechanism calculates the position of the inner surface of the vessel based on the information from a direction indicator and a height indicator. (4) A frontal limit detector detects the limit for allowing the radiation detector to proceed. (5) A vessel inner shape judging mechanism for judging the shape of the inner side of the vessel based on the signals from the proximity switches in a state where the frontal limit detector is operated and a vessel inner surface position signal outputted from the vessel inner surface position calculation mechanism. As a result, the shape of the inner side of the vessel can accurately be recognized, thereby improving accuracy of radiation measurement. (I.S.)

  6. Measurement and removal of surface contamination

    International Nuclear Information System (INIS)

    Neider, M.; Tamberg, T.

    1990-01-01

    This is a critical reappraisal of the sampling factor which is important for indirect contamination measurement. The factor gives the radioactivity collected by means of a wipe sample as a fraction of the total loose radioactivity i.e. without firm adhesion. It is used in national and international standard specifications and stated, frequently with excessive conservatism, as 0.1. Secondly, the standard specifications for the testing and appraisal of surface materials in relation to their decontamination capacity and for testing the effect of decontamination agents hitherto bond and Co-60 and Cs-137 are to be expanded to include radioactive iodine, which is important in nuclear medicine. The selection of optimum surface materials will thus be put on an improved basis. (orig./DG) [de

  7. 40 CFR 141.61 - Maximum contaminant levels for organic contaminants.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Maximum contaminant levels for organic contaminants. 141.61 Section 141.61 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER... Regulations: Maximum Contaminant Levels and Maximum Residual Disinfectant Levels § 141.61 Maximum contaminant...

  8. Synthesis of present methods of surface contamination detection (skin, clothes, laboratories)

    International Nuclear Information System (INIS)

    Joudrier, P.

    1983-01-01

    The signification of the term ''contamination'' is briefly recalled. To measure the levels of contamination, there are only two methods: the direct method and the indirect method. Finally, the recent improvements in the surface contamination detection field are shortly reviewed [fr

  9. Characterization of surface water contaminants in the Clinch River and Poplar Creek

    International Nuclear Information System (INIS)

    Ford, C.; Madix, S.; Rash, C.

    1995-01-01

    Surface waters in the Clinch River and Poplar Creek have been contaminated by activities on the DOE's Oak Ridge Reservation throughout the more than 50 year history of Oak Ridge. Though the Clinch River and Poplar Creek drainage areas are contaminated with heavy metals, organics and radionuclides, public access to these sites is not restricted. The investigation, divided into discrete studies, was tailored to provide a statistically sound picture of contaminants and aqueous toxicity in Poplar Creek, investigate contaminant remobilization from sediments, and determine contaminant levels during a series of ''worst-case'' events. Results for Poplar Creek indicate that average contaminant values were below levels of concern for human health and ecological risk, though contaminant distributions suggest that episodic events contribute sufficiently to system contaminant levels to be of concern. Additionally, water column contaminant levels were significantly higher in particle deposition areas rather than at known contaminant sources. Levels of organic compounds in reference areas to Poplar Creek exceeded those in the Poplar Creek study area. In the Clinch River and Poplar Creek, statistical differences in metal and radionuclide levels from known contaminated areas confirmed previous results, and were used to independently distinguish between sites. Contaminant concentrations were elevated in association with sediments, though no distinction between deposition and remobilization could be made. Due to elevated contaminant levels, and some unexpected contaminant distributions, sites in Poplar Creek and off-channel embayments of the Clinch River were identified that will require additional characterization

  10. Radioactive contamination level of vehicles resulted from transporting fine rare-earth minerals by rail

    International Nuclear Information System (INIS)

    Han Kaichun; Yu Boyong; Gao Shengwei

    1997-01-01

    This paper presents monitoring results of radioactive contamination level of steel open wagon surface resulted from transporting fine rare-earth minerals. Under promising transport conditions (the packaging consists of two layers of plastic bags and two layers of plastic net sacks, each package contains 50 kg of minerals, each vehicle carries 60 t), the surface radioactivity (total α and total β) of 16 vehicles on two lines from Baotou to Wujiachuan (924 km) and from Baotou to Sankeshu (2236 km) was measured before loading, after unloading and washing, using α and β surface contamination detector. The results showed that the radioactive contamination level of the vehicle surface after unloading appeared significantly different. The contamination level of vehicle bases was higher than that of both sides, long distance vehicles was higher than that of short distance vehicles. The radioactive contamination level of vehicles surface after washing was below the standard limits, these vehicles can be used for ordinary goods transport

  11. Analysis of surface contaminants on beryllium and aluminum windows

    International Nuclear Information System (INIS)

    Gmur, N.F.

    1987-06-01

    An effort has been made to document the types of contamination which form on beryllium window surfaces due to interaction with a synchrotron radiation beam. Beryllium windows contaminated in a variety of ways (exposure to water and air) exhibited surface powders, gels, crystals and liquid droplets. These contaminants were analyzed by electron diffraction, electron energy loss spectroscopy, energy dispersive x-ray spectroscopy and wet chemical methods. Materials found on window surfaces include beryllium oxide, amorphous carbon, cuprous oxide, metallic copper and nitric acid. Aluminum window surface contaminants were also examined

  12. Developments in surface contamination and cleaning fundamentals and applied aspects

    CERN Document Server

    Kohli, Rajiv

    2015-01-01

    Developments in Surface Contamination and Cleaning, Vol. 1: Fundamentals and Applied Aspects, Second Edition, provides an excellent source of information on alternative cleaning techniques and methods for characterization of surface contamination and validation. Each volume in this series contains a particular topical focus, covering the key techniques and recent developments in the area. This volume forms the heart of the series, covering the fundamentals and application aspects, characterization of surface contaminants, and methods for removal of surface contamination. In addition, new cleaning techniques effective at smaller scales are considered and employed for removal where conventional cleaning techniques fail, along with new cleaning techniques for molecular contaminants. The Volume is edited by the leading experts in small particle surface contamination and cleaning, providing an invaluable reference for researchers and engineers in R&D, manufacturing, quality control, and procurement specific...

  13. 40 CFR 141.13 - Maximum contaminant levels for turbidity.

    Science.gov (United States)

    2010-07-01

    ... turbidity. 141.13 Section 141.13 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER... Maximum contaminant levels for turbidity. The maximum contaminant levels for turbidity are applicable to... part. The maximum contaminant levels for turbidity in drinking water, measured at a representative...

  14. 40 CFR 141.62 - Maximum contaminant levels for inorganic contaminants.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Maximum contaminant levels for inorganic contaminants. 141.62 Section 141.62 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Water Regulations: Maximum Contaminant Levels and Maximum Residual Disinfectant Levels § 141.62 Maximum...

  15. 40 CFR 141.63 - Maximum contaminant levels (MCLs) for microbiological contaminants.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Maximum contaminant levels (MCLs) for microbiological contaminants. 141.63 Section 141.63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Water Regulations: Maximum Contaminant Levels and Maximum Residual Disinfectant Levels § 141.63 Maximum...

  16. Bonding of radioactive contamination. IV. Effect of surface finish

    International Nuclear Information System (INIS)

    Rankin, W.N.

    1983-01-01

    The mechanisms by which radioactive contamination would be bonded to a DWPF canister are being investigated. Previous investigations in this series have examined the effects of temperature, oxidation before contamination, and atmosphere composition control on the bonding of contamination. This memorandum describes the results of tests to determine the effect of special surface finishes on the bonding of contamination to waste glass canisters. Surface pretreatments which produce smoother canister surfaces actually cause radioactive contamination to be more tightly bonded to the metal surface than on an untreated surface. Based on the results of these tests it is recommended that the canister surface finish be specified as having a bright cold rolled mill finish equivalent to ASTM No. 2B. 7 references, 3 figures, 3 tables

  17. Modeling Groundwater-Surface Water Interaction and Contaminant Transport of Chlorinated Solvent Contaminated Site

    Science.gov (United States)

    Yimer Ebrahim, Girma; Jonoski, Andreja; van Griensven, Ann; Dujardin, Juliette; Baetelaan, Okke; Bronders, Jan

    2010-05-01

    Chlorinated-solvent form one of the largest groups of environmental chemicals. Their use and misuse in industry have lead to a large entry of these chemicals into the environment, resulting in widespread dissemination and oftentimes environmental contamination. Chlorinated solvent contamination of groundwater resources has been widely reported. For instance, there has been much interest in the assessment of these contaminant levels and their evolutions with time in the groundwater body below the Vilvoorde-Machelen industrial area (Belgium). The long industrial history of the area has lead to complex patterns of pollution from multiple sources and the site has been polluted to the extent that individual plumes are not definable any more. Understanding of groundwater/surface water interaction is a critical component for determining the fate of contaminant both in streams and ground water due to the fact that groundwater and surface water are in continuous dynamic interaction in the hydrologic cycle. The interaction has practical consequences in the quantity and quality of water in either system in the sense that depletion and/or contamination of one of the system will eventually affect the other one. The transition zone between a stream and its adjacent aquifer referred to as the hyporheic zone plays a critical role in governing contaminant exchange and transformation during water exchange between the two water bodies. The hyporheic zone of Zenne River ( the main receptor ) is further complicated due to the fact that the river banks are artificially trained with sheet piles along its reach extending some 12 m below the surface. This study demonstrates the use of MODFLOW, a widely used modular three-dimensional block-centred finite difference, saturated flow model for simulating the flow and direction of movement of groundwater through aquifer and stream-aquifer interaction and the use of transport model RT3D, a three-dimensional multi-species reactive transport model

  18. High level bacterial contamination of secondary school students' mobile phones.

    Science.gov (United States)

    Kõljalg, Siiri; Mändar, Rando; Sõber, Tiina; Rööp, Tiiu; Mändar, Reet

    2017-06-01

    While contamination of mobile phones in the hospital has been found to be common in several studies, little information about bacterial abundance on phones used in the community is available. Our aim was to quantitatively determine the bacterial contamination of secondary school students' mobile phones. Altogether 27 mobile phones were studied. The contact plate method and microbial identification using MALDI-TOF mass spectrometer were used for culture studies. Quantitative PCR reaction for detection of universal 16S rRNA, Enterococcus faecalis 16S rRNA and Escherichia coli allantoin permease were performed, and the presence of tetracycline ( tet A, tet B, tet M), erythromycin ( erm B) and sulphonamide ( sul 1) resistance genes was assessed. We found a high median bacterial count on secondary school students' mobile phones (10.5 CFU/cm 2 ) and a median of 17,032 bacterial 16S rRNA gene copies per phone. Potentially pathogenic microbes ( Staphylococcus aureus , Acinetobacter spp. , Pseudomonas spp., Bacillus cereus and Neisseria flavescens ) were found among dominant microbes more often on phones with higher percentage of E. faecalis in total bacterial 16S rRNA. No differences in contamination level or dominating bacterial species between phone owner's gender and between phone types (touch screen/keypad) were found. No antibiotic resistance genes were detected on mobile phone surfaces. Quantitative study methods revealed high level bacterial contamination of secondary school students' mobile phones.

  19. Improvement of a device for monitoring the contamination of surfaces

    International Nuclear Information System (INIS)

    Barbier, Albert.

    1981-01-01

    The purpose of this invention is to make it possible to monitor the contamination of surfaces by a light weight portable device and enabling the alpha, beta and gamma radiation contamination to be detected. The detection probe which is connected by a single lead to the box is adapted, in each particular case, to the radiation mode emitted by the contaminated surfaces and the box is provided with a special leak-proof socket for connecting the probe and includes means for assessing the counting rate of the radiation given off, depending on the mode of the radiations emitted by the contaminated surfaces and the intensity of the count rate [fr

  20. 40 CFR 141.51 - Maximum contaminant level goals for inorganic contaminants.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Maximum contaminant level goals for inorganic contaminants. 141.51 Section 141.51 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Maximum Contaminant Level...

  1. 40 CFR 141.50 - Maximum contaminant level goals for organic contaminants.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Maximum contaminant level goals for organic contaminants. 141.50 Section 141.50 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Maximum Contaminant Level...

  2. 40 CFR 141.52 - Maximum contaminant level goals for microbiological contaminants.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Maximum contaminant level goals for microbiological contaminants. 141.52 Section 141.52 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Maximum Contaminant Level...

  3. Development and validation of a highly sensitive gas chromatographic-mass spectrometric screening method for the simultaneous determination of nanogram levels of fentanyl, sufentanil and alfentanil in air and surface contamination wipes.

    Science.gov (United States)

    Van Nimmen, Nadine F J; Veulemans, Hendrik A F

    2004-05-07

    A highly sensitive gas chromatographic-mass spectrometric (GC-MS) analytical method for the determination of the opioid narcotics fentanyl, alfentanil, and sufentanil in industrial hygiene personal air samples and surface contamination wipes was developed and comprehensively validated. Sample preparation involved a single step extraction of the samples with methanol, fortified with a fixed amount of the penta-deuterated analogues of the opioid narcotics as internal standard. The GC-MS analytical procedure using selected ion monitoring (SIM) was shown to be highly selective. Linearity was shown for levels of extracted wipe and air samples corresponding to at least 0.1-2 times their surface contamination limit (SCL) and accordingly to 0.1-2 times their time weighted average occupational exposure limit (OEL-TWA) based on a full shift 9601 air sample. Extraction recoveries were determined for spiked air samples and surface wipes and were found to be quantitative for both sampling media in the entire range studied. The air sampling method's limit of detection (LOD) was determined to be 0.4 ng per sample for fentanyl and sufentanil and 1.6 ng per sample for alfentanil, corresponding to less than 1% of their individual OEL for a full shift air sample (9601). The limit of quantification (LOQ) was found to be 1.4, 1.2, and 5.0 ng per filter for fentanyl, sufentanil, and alfentanil, respectively. The wipe sampling method had LODs of 4 ng per wipe for fentanyl and sufentanil and 16 ng per wipe for alfentanil and LOQs of respectively, 14, 12, and 50 ng per wipe. The analytical intra-assay precision of the air sampling and wipe sampling method, defined as the coefficient of variation on the analytical result of six replicate spiked media was below 10 and 5%, respectively, for all opioids at all spike levels. Accuracy expressed as relative error was determined to be below 10%, except for alfentanil at the lowest spike level (-13.1%). The stability of the opioids during simulated

  4. Development of portable and automatic smear sampler for measuring surface contamination

    International Nuclear Information System (INIS)

    Lee, Bong Jae; Chang, S. Y.; Kim, B. H.; Kim, J. S.; Lee, H. S.; Kim, C. K.; Swol, C. W.

    2000-12-01

    In measuring radioactive contamination in radiation controlled area of nuclear facility, the technical criteria to evaluate surface contamination level and to sample by indirect method was established in this paper. Radioactive materials always present on surface within operating nuclear facilities. Because of the presence of interfering radiation field, health physicists take smear samples to monitoring surface contamination according to routine monitoring program. But there are some problems like great errors and difference of personnel. Then, to solve them, The portable and automatic smear sampling apparatus was designed and fabricated

  5. Development of portable and automatic smear sampler for measuring surface contamination

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Bong Jae; Chang, S. Y.; Kim, B. H.; Kim, J. S.; Lee, H. S.; Kim, C. K.; Swol, C. W

    2000-12-01

    In measuring radioactive contamination in radiation controlled area of nuclear facility, the technical criteria to evaluate surface contamination level and to sample by indirect method was established in this paper. Radioactive materials always present on surface within operating nuclear facilities. Because of the presence of interfering radiation field, health physicists take smear samples to monitoring surface contamination according to routine monitoring program. But there are some problems like great errors and difference of personnel. Then, to solve them, The portable and automatic smear sampling apparatus was designed and fabricated.

  6. Body-surface contamination monitoring preparatory to monitoring for internal contamination

    International Nuclear Information System (INIS)

    Schlueter, W.; Klucke, H.

    1980-01-01

    Measurements in the whole-body counter of the SAAS are routinely preceded by a thorough inspection of the patients for body-surface contamination to protect the sensitive counting equipment against becoming contaminated and to avoid a falsified indication of incorporated radionuclides. The measuring system employed for these examinations is described. (author)

  7. Contaminant interferences with SIMS analyses of microparticle impactor residues on LDEF surfaces

    International Nuclear Information System (INIS)

    Simon, C.G.; Batchelor, D.; Griffis, D.P.; Hunter, J.L.; Misra, V.; Ricks, D.A.; Wortman, J.J.

    1992-01-01

    Elemental analyses of impactor residues on high purity surface exposed to the low earth orbit (LEO) environment for 5.8 years on Long Duration Exposure Facility (LDEF) has revealed several probable sources for microparticles at this altitude, including natural micrometeorites and manmade debris ranging from paint pigments to bits of stainless steel. A myriad of contamination interferences were identified and their effects on impactor debris identification mitigated during the course of this study. These interferences included pre-, post-, and in-flight deposited particulate surface contaminants, as well as indigenous heterogeneous material contaminants. Non-flight contaminants traced to human origins, including spittle and skin oils, contributed significant levels of alkali-rich carbonaceous interferences. A ubiquitous layer of in-flight deposited silicaceous contamination varied in thickness with location on LDEF and proximity to active electrical fields. In-flight deposited (low velocity) contaminants included urine droplets and bits of metal film from eroded thermal blankets

  8. Decontamination of plutonium-contaminated surfaces

    International Nuclear Information System (INIS)

    Bertrand, J.; Clouet d'Orval, Ch.; Tachon, J.

    1958-01-01

    The measure of the neutron distribution in the core of 'Proserpine', by means of activation detectors, requires no contact between the plutonium sulfate solution and the detectors. These detectors are put into PVC or polyethylene bags. This report describes the process used to decontaminate these bags. A washing by nitric acid followed by coating with plexiglass is kept, with this process we have no contamination on the detectors. (author) [fr

  9. Modeling of laser damage initiated by surface contamination

    International Nuclear Information System (INIS)

    Feit, M.D.; Rubenchik, A.M.; Faux, D.R.; Riddle, R.A.; Shapiro, A.; Eder, D.C.; Penetrante, B.M.; Milam, D.; Genin, F.Y.; Kozlowski, M.R.

    1996-11-01

    The authors are engaged in a comprehensive effort to understand and model the initiation and growth of laser damage initiated by surface contaminants. This includes, for example, the initial absorption by the contaminant, heating and plasma generation, pressure and thermal loading of the transparent substrate, and subsequent shockwave propagation, 'splashing' of molten material and possible spallation, optical propagation and scattering, and treatment of material fracture. The integration use of large radiation hydrodynamics codes, optical propagation codes and material strength codes enables a comprehensive view of the damage process The following picture of surface contaminant initiated laser damage is emerging from our simulations

  10. Optimization in the nuclear fuel cycle II: Surface contamination

    International Nuclear Information System (INIS)

    Pereira, W.S.; Silva, A.X.; Lopes, J.M.; Carmo, A.S.; Fernandes, T.S.; Mello, C.R.; Kelecom, A.

    2017-01-01

    Optimization is one of the bases of radioprotection and aims to move doses away from the dose limit that is the borderline of acceptable radiological risk. This work aims to use the monitoring of surface contamination as a tool of the optimization process. 53 surface contamination points were analyzed at a nuclear fuel cycle facility. Three sampling points were identified with monthly mean values of contamination higher than 1 Bq ∙ cm -2 , points 28, 42 and 47. These points were indicated for the beginning of the optimization process

  11. Contamination levels observed on the Belgian territory subsequent to the Chernobyl accident

    International Nuclear Information System (INIS)

    Cottens, E.

    1986-01-01

    A summary of the data from different laboratories concerning the fallout on the Belgian territory following the Chernobyl emissions is presented. The evolution of the particulate air activity at ground level, the integrated fallout captured in water, the deposition on soil surface directly for different localities in Belgium are given. The grass contamination, the milk contamination from individual farms, the concentration levels on leafy vegetables, surface waters and water basins and the contamination of meat during the month of May are presented. (A.F.)

  12. Automation system for tritium contaminated surface monitoring

    International Nuclear Information System (INIS)

    Culcer, Mihai; Iliescu, Mariana; Curuia, Marian; Raceanu, Mircea; Enache, Adrian; Stefanescu, Ioan; Ducu, Catalin; Malinovschi, Viorel

    2005-01-01

    The low energy of betas makes tritium difficult to detect. However, there are several methods used in tritium detection, such as liquid scintillation and ionization chambers. Tritium on or near a surface can be also detected using proportional counter and, recently, solid state devices. The paper presents our results in the design and achievement of a surface tritium monitor using a PIN photodiode as a solid state charged particle detector to count betas emitted from the surface. That method allows continuous, real-time and non-destructively measuring of tritium. (authors)

  13. Estimating dermal transfer from PCB-contaminated porous surfaces.

    Science.gov (United States)

    Slayton, T M; Valberg, P A; Wait, A D

    1998-06-01

    Health risks posed by dermal contact with PCB-contaminated porous surfaces have not been directly demonstrated and are difficult to estimate indirectly. Surface contamination by organic compounds is commonly assessed by collecting wipe samples with hexane as the solvent. However, for porous surfaces, hexane wipe characterization is of limited direct use when estimating potential human exposure. Particularly for porous surfaces, the relationship between the amount of organic material collected by hexane and the amount actually picked up by, for example, a person's hand touch is unknown. To better mimic PCB pickup by casual hand contact with contaminated concrete surfaces, we used alternate solvents and wipe application methods that more closely mimic casual dermal contact. Our sampling results were compared to PCB pickup using hexane-wetted wipes and the standard rubbing protocol. Dry and oil-wetted samples, applied without rubbing, picked up less than 1% of the PCBs picked up by the standard hexane procedure; with rubbing, they picked up about 2%. Without rubbing, saline-wetted wipes picked up 2.5%; with rubbing, they picked up about 12%. While the nature of dermal contact with a contaminated surface cannot be perfectly reproduced with a wipe sample, our results with alternate wiping solvents and rubbing methods more closely mimic hand contact than the standard hexane wipe protocol. The relative pickup estimates presented in this paper can be used in conjunction with site-specific PCB hexane wipe results to estimate dermal pickup rates at sites with PCB-contaminated concrete.

  14. Development of an automatic smear sampler and evaluation of surface contamination

    International Nuclear Information System (INIS)

    Seo, B. K.; Lee, B. J.; Lee, K. W.; Park, J. H.

    2004-01-01

    The surface contamination level of a radiation-controlled area is measured periodically according to atomic energy law and connection regulations. The measurement of surface contamination by an indirect method is subject to various kinds of error depending on the sampling person and consumes much time and effort in the sampling of large nuclear facilities. In this research, an automatic smear sampler is developed to solve these problems. The developed equipment is composed of a rotating sampling part, a sample transferring part, a power supply part a control part, and vacuum part. It improved the efficiency of estimation of the surface contamination level achieved periodically in a radiation-controlled area. Using an automatic smear sampler developed in this research, it is confirmed that radioactive contaminated materials are uniformly transferred to smear paper more than any sampling method by an operator. (authors)

  15. Process for cleaning radioactively contaminated metal surfaces

    International Nuclear Information System (INIS)

    Mihram, R.G.; Snyder, G.A.

    1975-01-01

    A process is described for removing radioactive scale from a ferrous metal surface, including the steps of initially preconditioning the surface by contacting it with an oxidizing solution (such as an aqueous solution of an alkali metal permanganate or hydrogen peroxide), then, after removal or decomposition of the oxidizing solution, the metallic surface is contacted with a cleaning solution which is a mixture of a mineral acid and a complexing agent (such as sulfuric acid and oxalic acid), and which preferably contains a corrosion inhibitor. A final step in the process is the treatment of the spent cleaning solution containing radioactive waste materials in solution by adding a reagent selected from the group consisting of calcium hydroxide or potassium permanganate and an alkali metal hydroxide to thereby form easily recovered metallic compounds containing substantially all of the dissolved metals and radioactivity. (auth)

  16. Levels and trends of contaminants in humans of the Arctic.

    Science.gov (United States)

    Gibson, Jennifer; Adlard, Bryan; Olafsdottir, Kristin; Sandanger, Torkjel Manning; Odland, Jon Øyvind

    2016-01-01

    The Arctic Monitoring and Assessment Programme (AMAP) is one of the six working groups established under the Arctic Council. AMAP is tasked with monitoring the levels of contaminants present in the Arctic environment and people as well as assessing their effects on a continuous basis, and reporting these results regularly. Most of the presented data have been collected over the last 20 years and are from all eight Arctic countries. Levels of contaminants appear to be declining in some of the monitored Arctic populations, but it is not consistent across the Arctic. Most Arctic populations continue to experience elevated levels of these contaminants compared to other populations monitored globally. There are certain contaminants, such as perfluorinated compounds and polybrominated diphenyl ethers, which are still increasing in Arctic populations. These contaminants require more investigation to find out the predominant and important sources of exposure, and whether they are being transported to the Arctic through long-range transport in the environment.

  17. Measurement of residual radioactive surface contamination by 2-D laser heated TLD

    International Nuclear Information System (INIS)

    Jones, S.C.

    1997-06-01

    The feasibility of applying and adapting a two-dimensional laser heated thermoluminescence dosimetry system to the problem of surveying for radioactive surface contamination was studied. The system consists of a CO 2 laser-based reader and monolithic arrays of thin dosimeter elements. The arrays consist of 10,201 thermoluminescent phosphor elements of 40 micron thickness, covering a 900 cm 2 area. Array substrates are 125 micron thick polyimide sheets, enabling them to easily conform to regular surface shapes, especially for survey of surfaces that are inaccessible for standard survey instruments. The passive, integrating radiation detectors are sensitive to alpha and beta radiation at contamination levels below release guideline limits. Required contact times with potentially contaminated surfaces are under one hour to achieve detection of transuranic alpha emission at 100 dpm/100 cm 2 . Positional information obtained from array evaluation is useful for locating contamination zones. Unique capabilities of this system for survey of sites, facilities and material include measurement inside pipes and other geometrical configurations that prevent standard surveys, and below-surface measurement of alpha and beta emitters in contaminated soils. These applications imply a reduction of material that must be classified as radioactive waste by virtue of its possibility of contamination, and cost savings in soil sampling at contaminated sites

  18. Cleaning, disinfection and sterilization of surface prion contamination.

    Science.gov (United States)

    McDonnell, G; Dehen, C; Perrin, A; Thomas, V; Igel-Egalon, A; Burke, P A; Deslys, J P; Comoy, E

    2013-12-01

    Prion contamination is a risk during device reprocessing, being difficult to remove and inactivate. Little is known of the combined effects of cleaning, disinfection and sterilization during a typical reprocessing cycle in clinical practice. To investigate the combination of cleaning, disinfection and/or sterilization on reducing the risk of surface prion contamination. In vivo test methods were used to study the impact of cleaning alone and cleaning combined with thermal disinfection and high- or low-temperature sterilization processes. A standardized test method, based on contamination of stainless steel wires with high titres of scrapie-infected brain homogenates, was used to determine infectivity reduction. Traditional chemical methods of surface decontamination against prions were confirmed to be effective, but extended steam sterilization was more variable. Steam sterilization alone reduced the risk of prion contamination under normal or extended exposure conditions, but did show significant variation. Thermal disinfection had no impact in these studies. Cleaning with certain defined formulations in combination with steam sterilization can be an effective prion decontamination process, in particular with alkaline formulations. Low-temperature, gaseous hydrogen peroxide sterilization was also confirmed to reduce infectivity in the presence and absence of cleaning. Prion decontamination is affected by the full reprocessing cycle used on contaminated surfaces. The correct use of defined cleaning, disinfection and sterilization methods as tested in this report in the scrapie infectivity assay can provide a standard precaution against prion contamination. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  19. Analysis of surface contaminants on beryllium windows

    International Nuclear Information System (INIS)

    Gmur, N.F.

    1986-12-01

    It is known that various crystalline and liquid compounds form on the downstream surfaces of beryllium windows exposed to air. It is also known that the integrity of such windows may be compromised resulting in leaks through the window. The purpose of this report is to document the occurrences described as they pertain to the NSLS and to analyze, where possible, the various substances formed

  20. Release of Streptomyces albus propagules from contaminated surfaces

    International Nuclear Information System (INIS)

    Gorny, R.L.; Mainelis, Gediminas; Grinshpun, Sergey A.; Willeke, Klaus; Dutkiewicz, Jacek; Reponen, Tiina

    2003-01-01

    The release of Streptomyces albus propagules from contaminated agar an ceiling tile surfaces was studied under controlled environmental condition in a newly developed aerosolization chamber. The experiments revealed tha both spores and cell fragments can be simultaneously released from the colonized surface by relatively gentle air currents of 0.3 m s -1 . A 100x increase of the air velocity can result in a 50-fold increase in the number of released propagules. The aerosolization rate depends strongly on the typ and roughness of the contaminated surface. Up to 90% of available actinomycete propagules can become airborne during the first 10 min of th release process. Application of vibration to the surface did not reveal an influence on the aerosolization process of S. albus propagules under th tested conditions. This study has shown that propagules in the fine particle size range can be released in large amounts from contaminated surfaces Measurement of the number of S. albus fragments in the vicinity of contaminated area, as an alternative to conventional air or surface sampling appears to be a promising approach for quantitative exposure assessment

  1. Materials SIG quantification and characterization of surface contaminants

    Science.gov (United States)

    Crutcher, E. Russ

    1992-01-01

    When LDEF entered orbit its cleanliness was approximately a MIL-STD-1246B Level 2000C. Its burden of contaminants included particles from every part of its history including a relatively small contribution from the shuttle bay itself. Although this satellite was far from what is normally considered clean in the aerospace industry, contaminating events in orbit and from processing after recovery were easily detected. The molecular contaminants carried into orbit were dwarfed by the heavy deposition of UV polymerized films from outgassing urethane paints and silicone based materials. Impacts by relatively small objects in orbit could create particulate contaminants that easily dominated the particle counts within a centimeter of the impact site. During the recovery activities LDEF was 'sprayed' with a liquid high in organics and water soluble salts. With reentry turbulence, vibration, and gravitational loading particulate contaminants were redistributed about LDEF and the shuttle bay.

  2. A New Method for Processing Airborne Gamma Ray Spectrometry Data for Mapping Low Level Contaminations

    DEFF Research Database (Denmark)

    Aage, Helle Karina; Korsbech, Uffe C C; Bargholz, Kim

    1999-01-01

    A new technique for processing airborne gamma ray spectrometry data has been developed. It is based on the noise adjusted singular value decomposition method introduced by Hovgaard in 1997. The new technique opens for mapping of very low contamination levels. It is tested with data from Latvia...... where the remaining contamination from the 1986 Chernobyl accident together with fallout from the atmospheric nuclear weapon tests includes Cs-137 at levels often well below 1 kBq/m(2) equivalent surface contamination. The limiting factors for obtaining reliable results are radon in the air, spectrum...

  3. Assessment of low levels of radioactive contamination

    International Nuclear Information System (INIS)

    Gray, P.W.

    1988-01-01

    This report describes a general methodology for the verification and clearance of sites contaminated with radioactive materials; general expressions for the risk or health detriment are derived. Techniques are developed, using Bayesian decision theory, to optimize the resources allocated to a site monitoring procedure, and to construct the probability distribution of the spatial distribution of specific activity within a site. A technique is also developed to determine the probability that a localized source of specified characteristics will not be detected by the monitoring procedure employed. The application of these techniques is illustrated by means of simple examples. This report confirms that a very large number of measurements are needed if a source of localized activity is to be detected with a high probability, and demonstrates how prior information about past radiological practices might be used to increase the probability of detection. Proposals are made for a programme of research to determine whether or not representative sites can be verified using current measuring techniques. (author)

  4. Techniques for removing contaminants from optical surfaces

    International Nuclear Information System (INIS)

    Stowers, I.F.; Patton, H.G.

    1978-01-01

    Particle removal procedures such as plasma cleaning, ultrasonic agitation of solvents, detergents, solvent wiping, mild abrasives, vapor degreasing, high pressure solvent spraying and others have been evaluated and the results are reported here. Wiping with a lens tissue wetted with an organic solvent and high pressure fluid spraying are the only methods by which particles as small as 5 μm can be effectively removed. All of the other methods tested were found to be at least two orders of magnitude less effective at removing small insoluble particles. An additional and as yet unresolved problem is the development of a reliable method for evaluating particulate surface cleanliness. Without such a reproducible monitoring technique, the large diversity of cleaning methods currently available cannot be quantitatively evaluated

  5. SUDOQU, a new dose-assessment methodology for radiological surface contamination.

    Science.gov (United States)

    van Dillen, Teun; van Dijk, Arjan

    2018-06-12

    A new methodology has been developed for the assessment of the annual effective dose resulting from removable and fixed radiological surface contamination. It is entitled SUDOQU (SUrface DOse QUantification) and it can for instance be used to derive criteria for surface contamination related to the import of non-food consumer goods, containers and conveyances, e.g., limiting values and operational screening levels. SUDOQU imposes mass (activity)-balance equations based on radioactive decay, removal and deposition processes in indoor and outdoor environments. This leads to time-dependent contamination levels that may be of particular importance in exposure scenarios dealing with one or a few contaminated items only (usually public exposure scenarios, therefore referred to as the 'consumer' model). Exposure scenarios with a continuous flow of freshly contaminated goods also fall within the scope of the methodology (typically occupational exposure scenarios, thus referred to as the 'worker model'). In this paper we describe SUDOQU, its applications, and its current limitations. First, we delineate the contamination issue, present the assumptions and explain the concepts. We describe the relevant removal, transfer, and deposition processes, and derive equations for the time evolution of the radiological surface-, air- and skin-contamination levels. These are then input for the subsequent evaluation of the annual effective dose with possible contributions from external gamma radiation, inhalation, secondary ingestion (indirect, from hand to mouth), skin contamination, direct ingestion and skin-contact exposure. The limiting effective surface dose is introduced for issues involving the conservatism of dose calculations. SUDOQU can be used by radiation-protection scientists/experts and policy makers in the field of e.g. emergency preparedness, trade and transport, exemption and clearance, waste management, and nuclear facilities. Several practical examples are worked

  6. Monitoring of tritium-contaminated surfaces, including skin

    Energy Technology Data Exchange (ETDEWEB)

    Surette, R A; Wood, M J

    1994-05-01

    We have examined various commercially available tritium surface contamination monitors along with different swipe media and techniques for direct and indirect (swipe) monitoring of contaminated surfaces, including skin. None of the methods or instruments evaluated were more sensitive than the swipe and liquid scintillation counting (LSC) method. Swipe measurements with open-window proportional counters were, in general, less than half as sensitive as LSC, but have the advantages of having the results available almost immediately, and no sample preparation is required. The Nuclear Measurement Corporation`s PC-55 is the most suitable instrument we tested for the analysis of routine swipe measurement. The PC-55 was about one third as sensitive as LSC when used with Ontario Hydro filter paper swipe media. Surface contamination measurement results can be obtained within minutes using the PC-55, compared to hours using LSC. The selection of swipe media for use with proportional counter-based instruments is critical. A medium that is electrically insulating can develop an electrostatic charge on its surface; this may alter the field gradient in the detector and may adversely influence the results. Although the PC-55 is sufficiently sensitive and very convenient, operational experience with the instrument is needed before recommending that it replace current LSC methods. The PC-55`s susceptibility to internal tritium contamination may limit its practical usefulness. Because of the complexity of using live animals to evaluate direct and indirect methods for assessing skin contamination, pig skin was investigated as a possible substitute. We concluded that, for the first few hours post-exposure, pig skin mimics the kinetics of animal skin that has contacted a tritium-contaminated surface. (author). 30 refs., 1 tab., 7 figs.

  7. Monitoring of tritium-contaminated surfaces, including skin

    International Nuclear Information System (INIS)

    Surette, R.A.; Wood, M.J.

    1994-05-01

    We have examined various commercially available tritium surface contamination monitors along with different swipe media and techniques for direct and indirect (swipe) monitoring of contaminated surfaces, including skin. None of the methods or instruments evaluated were more sensitive than the swipe and liquid scintillation counting (LSC) method. Swipe measurements with open-window proportional counters were, in general, less than half as sensitive as LSC, but have the advantages of having the results available almost immediately, and no sample preparation is required. The Nuclear Measurement Corporation's PC-55 is the most suitable instrument we tested for the analysis of routine swipe measurement. The PC-55 was about one third as sensitive as LSC when used with Ontario Hydro filter paper swipe media. Surface contamination measurement results can be obtained within minutes using the PC-55, compared to hours using LSC. The selection of swipe media for use with proportional counter-based instruments is critical. A medium that is electrically insulating can develop an electrostatic charge on its surface; this may alter the field gradient in the detector and may adversely influence the results. Although the PC-55 is sufficiently sensitive and very convenient, operational experience with the instrument is needed before recommending that it replace current LSC methods. The PC-55's susceptibility to internal tritium contamination may limit its practical usefulness. Because of the complexity of using live animals to evaluate direct and indirect methods for assessing skin contamination, pig skin was investigated as a possible substitute. We concluded that, for the first few hours post-exposure, pig skin mimics the kinetics of animal skin that has contacted a tritium-contaminated surface. (author). 30 refs., 1 tab., 7 figs

  8. Environmental contaminants of emerging concern in seafood – European database on contaminant levels

    International Nuclear Information System (INIS)

    Vandermeersch, Griet; Lourenço, Helena Maria; Alvarez-Muñoz, Diana; Cunha, Sara; Diogène, Jorge; Cano-Sancho, German; Sloth, Jens J.; Kwadijk, Christiaan; Barcelo, Damia; Allegaert, Wim; Bekaert, Karen; Fernandes, José Oliveira; Marques, Antonio

    2015-01-01

    Marine pollution gives rise to concern not only about the environment itself but also about the impact on food safety and consequently on public health. European authorities and consumers have therefore become increasingly worried about the transfer of contaminants from the marine environment to seafood. So-called “contaminants of emerging concern” are chemical substances for which no maximum levels have been laid down in EU legislation, or substances for which maximum levels have been provided but which require revision. Adequate information on their presence in seafood is often lacking and thus potential risks cannot be excluded. Assessment of food safety issues related to these contaminants has thus become urgent and imperative. A database ( (www.ecsafeseafooddbase.eu)), containing available information on the levels of contaminants of emerging concern in seafood and providing the most recent data to scientists and regulatory authorities, was developed. The present paper reviews a selection of contaminants of emerging concern in seafood including toxic elements, endocrine disruptors, brominated flame retardants, pharmaceuticals and personal care products, polycyclic aromatic hydrocarbons and derivatives, microplastics and marine toxins. Current status on the knowledge of human exposure, toxicity and legislation are briefly presented and the outcome from scientific publications reporting on the levels of these compounds in seafood is presented and discussed. - Highlights: • Development of a European database regarding contaminants of emerging concern. • Current status on knowledge of human exposure, toxicity and legislation. • Review on the occurrence of contaminants of emerging concern in seafood.

  9. Environmental contaminants of emerging concern in seafood – European database on contaminant levels

    Energy Technology Data Exchange (ETDEWEB)

    Vandermeersch, Griet, E-mail: griet.vandermeersch@ilvo.vlaanderen.be [Institute for Agricultural and Fisheries Research (ILVO), Animal Sciences Unit – Fisheries, Ankerstraat 1, 8400 Oostende (Belgium); Lourenço, Helena Maria [Division of Aquaculture and Upgrading (DivAV), Portuguese Institute for the Sea and Atmosphere (IPMA), Lisboa (Portugal); Alvarez-Muñoz, Diana [Catalan Institute for Water Research (ICRA), Girona (Spain); Cunha, Sara [LAQV-REQUIMTE, Laboratory of Bromatology and Hydrology, Faculty of Pharmacy, University of Porto, Rua Jorge de Viterbo Ferreira 228, 4050-313 Porto (Portugal); Diogène, Jorge [Institute of Research and Technology in Food and Agriculture (IRTA), Sant Carles de la Ràpita (Spain); Cano-Sancho, German [Laboratory of Toxicology and Environmental Health, School of Medicine, Rovirai Virgili University (URV), Reus (Spain); Sloth, Jens J. [National Food Institute, Technical University of Denmark (DTU Food), Søborg (Denmark); Kwadijk, Christiaan [Institute for Marine Resources and Ecosystem Studies (IMARES), Wageningen University and Research Center, Ijmuiden (Netherlands); Barcelo, Damia [Catalan Institute for Water Research (ICRA), Girona (Spain); Water and Soil Quality Research Group, Department of Environmental Chemistry, IDAEA-CSIC, Barcelona (Spain); Allegaert, Wim; Bekaert, Karen [Institute for Agricultural and Fisheries Research (ILVO), Animal Sciences Unit – Fisheries, Ankerstraat 1, 8400 Oostende (Belgium); Fernandes, José Oliveira [LAQV-REQUIMTE, Laboratory of Bromatology and Hydrology, Faculty of Pharmacy, University of Porto, Rua Jorge de Viterbo Ferreira 228, 4050-313 Porto (Portugal); Marques, Antonio [Division of Aquaculture and Upgrading (DivAV), Portuguese Institute for the Sea and Atmosphere (IPMA), Lisboa (Portugal); and others

    2015-11-15

    Marine pollution gives rise to concern not only about the environment itself but also about the impact on food safety and consequently on public health. European authorities and consumers have therefore become increasingly worried about the transfer of contaminants from the marine environment to seafood. So-called “contaminants of emerging concern” are chemical substances for which no maximum levels have been laid down in EU legislation, or substances for which maximum levels have been provided but which require revision. Adequate information on their presence in seafood is often lacking and thus potential risks cannot be excluded. Assessment of food safety issues related to these contaminants has thus become urgent and imperative. A database ( (www.ecsafeseafooddbase.eu)), containing available information on the levels of contaminants of emerging concern in seafood and providing the most recent data to scientists and regulatory authorities, was developed. The present paper reviews a selection of contaminants of emerging concern in seafood including toxic elements, endocrine disruptors, brominated flame retardants, pharmaceuticals and personal care products, polycyclic aromatic hydrocarbons and derivatives, microplastics and marine toxins. Current status on the knowledge of human exposure, toxicity and legislation are briefly presented and the outcome from scientific publications reporting on the levels of these compounds in seafood is presented and discussed. - Highlights: • Development of a European database regarding contaminants of emerging concern. • Current status on knowledge of human exposure, toxicity and legislation. • Review on the occurrence of contaminants of emerging concern in seafood.

  10. Modelling of contamination of surface atmosphere for deflation of Cesium-137 on contaminated territories

    International Nuclear Information System (INIS)

    Bogdanov, A.P.; Zhmura, G.M.

    1994-01-01

    Presence of Cesium 137 in near land air is caused at the contaminated territories by 'local' dusting and transport of the dust from the zone of strong contamination. For large distance is it caused by resuspension of radioactive dust from the surface in the given region. In accordance with the models of dusting round square sources based on Gauss statistical model of dissemination of admixtures in the atmosphere, the contaminated areas of european part of the former of USSR with the density of contamination over 1 Ci/km 2 with Cesium 137 were represented by 30 round square sources covering the main spots of contamination. The results of calculation of contamination of the atmosphere for several cities of Belarus, Russia and Ukraine, where there are the permanent points of observation for the content of radionuclides in the air, have shown that the proposed model of dusting sources describes the contamination of near land air with Cesium 137 reasonably well. 7 refs., 3 tabs

  11. Surface soil contamination standards for Rockwell Hanford Operations

    International Nuclear Information System (INIS)

    Boothe, G.F.

    1981-01-01

    The 200 Areas of the Hanford site contain soils contaminated with levels of radioactivity ranging from fallout concentrations to levels requiring radiological controls. Some contamination is more or less uniformly distributed, and some occurs as discrete specks or spots of activity. Because of the acute need for standards, the Rockwell Environmental Protection (EP) Group proceeded to develop standards; these were approved by Rockwell in October 1979. It must be emphasized that these standards are only applicable to the 200 Areas of the Hanford site or other areas under Rockwell's jurisdiction. It is assumed that access to these areas will always be restricted and that land-use restrictions will be maintained. Contamination limits for areas used by the general public would normally be lower than the limits derived in this case. It appears that the Rockwell standards divided by a factor of 5 to 10 may be reasonable contamination guidelines for the general environment

  12. Allowable residual contamination levels for decommissioning. Part 2. A summary of example results

    International Nuclear Information System (INIS)

    Kennedy, W.E. Jr.; Napier, B.A.

    1985-01-01

    This paper contains a description of the results of a study sponsored by UNC Nuclear Industries to determine Allowable Residual Contamination Levels (ARCL) for decommissioning facilities in the 100 Areas of the Hanford Site. ARCL results are presented both for surface contamination remaining in facilities (in dpm/100 cm 2 ) and for unconfined surface and confined subsurface soil conditions (in pCi/g). Two confined soil conditions are considered: contamination at depths between 1 and 4 m, and contamination at depths greater than or equal to 5 m. A set of worksheets are discussed for modifying the ARCL values to accommodate changes in the radionuclide mixture or concentrations, to consider the impacts of radioactive decay, and to predict instrument responses. Finally, a comparison is made between the unrestricted release ARCL values for the 100 Area facilities and existing decommissioning and land disposal regulations. For surface contamination, the comparison shows good agreement for a selected annual dose limit. For soil contamination, the comparison shows good agreement if reasonable modification factors are applied to account for the differences in modeling soil contamination and licensed low-level waste. 6 references, 1 figures, 4 tables

  13. Environmental contaminants of emerging concern in seafood - European database on contaminant levels

    DEFF Research Database (Denmark)

    Vandermeersch, Griet; Lourenço, Helena Maria; Alvarez-Muñoz, Diana

    2015-01-01

    Marine pollution gives rise to concern not only about the environment itself but also about the impact on food safety and consequently on public health. European authorities and consumers have therefore become increasingly worried about the transfer of contaminants from the marine environment...... to seafood.So-called "contaminants of emerging concern" are chemical substances for which no maximum levels have been laid down in EU legislation, or substances for which maximum levels have been provided but which require revision. Adequate information on their presence in seafood is often lacking and thus...... potential risks cannot be excluded. Assessment of food safety issues related to these contaminants has thus become urgent and imperative. A database (www.ecsafeseafooddbase.eu), containing available information on the levels of contaminants of emerging concern in seafood and providing the most recent data...

  14. Development of a calibration system for surface contamination monitors

    International Nuclear Information System (INIS)

    Marechal, M.H.H.; Barbosa, M.P.

    1992-01-01

    A calibration system for surface contamination monitors is developed, aiming supply the existence demand of these instruments. A experimental arrangement and a methodology are described. The advantages of use this system for calibration routine optimization are also discussed. (C.G.C.)

  15. Influence of the target surface contamination on UHV screening energies

    Energy Technology Data Exchange (ETDEWEB)

    Targosz-Sleczka, N; Czerski, K; Kilic, A I [Institute of Physics, University of Szczecin, Szczecin (Poland); Huke, A; Martin, L; Heide, P [Institut fuer Atomare Physik und Optik, Technische Universitaet Berlin, Berlin (Germany); Blauth, D; Winter, H, E-mail: natalia.targosz@wmf.univ.szczecin.p [Institut fuer Physik, Humboldt-Universitaet zu Berlin, Berlin (Germany)

    2010-01-01

    The d + d fusion reactions have been investigated in the Zirconium environment under ultra high vacuum (UHV) conditions for projectile energies below 30 keV. The experimentally determined screening energy value of 497 {+-} 7 eV is larger than the previous results by a factor of almost two. Despite the UHV conditions a small deviation between experimental data and the theoretical curve arising from the target surface contamination could be still observed at the lowest projectile energies. Calculations made under the assumption of formation of a Zirconium oxide contamination, show that every atomic monolayer reduces the estimated screening energy significantly.

  16. Influence of the target surface contamination on UHV screening energies

    International Nuclear Information System (INIS)

    Targosz-Sleczka, N; Czerski, K; Kilic, A I; Huke, A; Martin, L; Heide, P; Blauth, D; Winter, H

    2010-01-01

    The d + d fusion reactions have been investigated in the Zirconium environment under ultra high vacuum (UHV) conditions for projectile energies below 30 keV. The experimentally determined screening energy value of 497 ± 7 eV is larger than the previous results by a factor of almost two. Despite the UHV conditions a small deviation between experimental data and the theoretical curve arising from the target surface contamination could be still observed at the lowest projectile energies. Calculations made under the assumption of formation of a Zirconium oxide contamination, show that every atomic monolayer reduces the estimated screening energy significantly.

  17. Laser Decontamination of Surfaces Contaminated with Cs+ Ion

    International Nuclear Information System (INIS)

    Baigalmaaa, B.; Won, H. J.; Moon, J. K.; Jung, C. H.; Lee, K. W.; Hyun, J. H.

    2008-01-01

    Laser decontamination technology has been proven to be an efficient method for a surface modification of metals and concretes contaminated with radioactive isotopes. Furthermore, the generation of a secondary waste is negligible. The radioactivity of hot cells in the DFDF (Dupic Fuel Development Facility) is presumed to be very high and the predominant radionuclide is Cs-137. A series of laser decontamination studies by a fabricated Q-switched Nd:YAG laser system were performed on stainless steel specimens artificially contaminated with Cs+ ion. Decontamination characteristics of the stainless steel were analyzed by SEM and EPMA

  18. Salinization and arsenic contamination of surface water in southwest Bangladesh.

    Science.gov (United States)

    Ayers, John C; George, Gregory; Fry, David; Benneyworth, Laura; Wilson, Carol; Auerbach, Leslie; Roy, Kushal; Karim, Md Rezaul; Akter, Farjana; Goodbred, Steven

    2017-09-11

    To identify the causes of salinization and arsenic contamination of surface water on an embanked island (i.e., polder) in the tidal delta plain of SW Bangladesh we collected and analyzed water samples in the dry (May) and wet (October) seasons in 2012-2013. Samples were collected from rice paddies (wet season), saltwater ponds used for brine shrimp aquaculture (dry season), freshwater ponds and tidal channels (both wet and dry season), and rainwater collectors. Continuous measurements of salinity from March 2012 to February 2013 show that tidal channel water increases from ~0.15 ppt in the wet season up to ~20 ppt in the dry season. On the polder, surface water exceeds the World Health Organization drinking water guideline of 10 μg As/L in 78% of shrimp ponds and 27% of rice paddies, raising concerns that produced shrimp and rice could have unsafe levels of As. Drinking water sources also often have unsafe As levels, with 83% of tubewell and 43% of freshwater pond samples having >10 μg As/L. Water compositions and field observations are consistent with shrimp pond water being sourced from tidal channels during the dry season, rather than the locally saline groundwater from tubewells. Irrigation water for rice paddies is also obtained from the tidal channels, but during the wet season when surface waters are fresh. Salts become concentrated in irrigation water through evaporation, with average salinity increasing from 0.43 ppt in the tidal channel source to 0.91 ppt in the rice paddies. Our observations suggest that the practice of seasonally alternating rice and shrimp farming in a field has a negligible effect on rice paddy water salinity. Also, shrimp ponds do not significantly affect the salinity of adjacent surface water bodies or subjacent groundwater because impermeable shallow surface deposits of silt and clay mostly isolate surface water bodies from each other and from the shallow groundwater aquifer. Bivariate plots of conservative element

  19. Strippable gel for decontamination of contaminated metallic surfaces

    International Nuclear Information System (INIS)

    Banerjee, D.; Sandhya, U.; Khot, S.A.; Srinivas, C.; Wattal, P.K.

    2013-01-01

    Periodic decontamination of radioactive laboratories including fume hoods, glove boxes and all surfaces used for handling, processing and transporting radioactive materials is mandatory in all nuclear installations as this reduces spread of contamination and decreases total man rem exposure. Conventionally, chemical decontaminating agents or surfactant solutions are used for this purpose. However, this approach leads to generation of large volume of secondary radioactive waste. The use of strippable gel is an attractive alternative with low secondary waste generation particularly where removal of loose or weakly fixed contamination is necessary and also when the decontaminated material are to be reused, for e.g. decontamination of fume hoods, glove boxes, transport casks, spent fuel storage racks, control rod drive transport containers etc. Literature on gel formulations is scarce and mostly in the patent form. The sustained effort on gel formulation development has resulted in a basic gel formulation. The gel is a highly viscous water-based organic polymer, particularly suitable for application on vertical surfaces including difficult to reach metallic surfaces of complex geometry and not just limited to horizontal surfaces. The gel can be easily applied on contaminated surfaces by brushing or spraying. Curing of the gel is complete within 16-24 hours under ambient conditions and can then be removed by peeling as a dry sheet. While curing, the contaminants are trapped in gel either physically or chemically depending upon the nature of the contaminant. Salient features of cured gel include that it is water soluble and can be disposed off after immobilization in cement. Decontamination performance of the gel was initially evaluated by applying it on SS planchettes contaminated with known amount of radionuclides such as Cs(I), Co(II) and Ce(III). The measured decontamination factor was found to be in the range of 50-500, lowest for Ce(III) and highest for Co

  20. Experiment on Physical Desalinisation of Uranium-contaminated Gravel Surface

    International Nuclear Information System (INIS)

    Park, Uk-Ryang; Kim, Gye-Nam; Kim, Seung-Soo; Han, Gyu-Seong; Moon, Jai-Kwon

    2014-01-01

    As a result, the method to wash uranium-contaminated gravels could not get satisfactory desalinization rate. During the long oxidization process it was judged that uranium penetrated inside the gravels, so we tried to increase the desalinization rate by fragmentizing them into pieces and then washing them. The desalinization rate after fragmentizing the gravels into pieces and washing them brought a satisfactory result.. However, we could obtain desired concentration for gravels with high uranium concentration by fragmentizing them and breaking them further into even smaller pieces. Likewise, desalinization using soil washing process is complicated and has to go through multiple washing steps, resulting in too much of waste fluid generated accordingly. The increase of waste fluid generated leads to the increase in by-products of the final disposal process later on, bringing a not good economic result. Furthermore, taking into account that the desalinization rate is 65% during soil washing process, it is expected that gravel washing will show a similar desalinization result; it is considered uneasy to have a perfect desalinization only by soil washing. The grinding method is actually used in the primary desalinization process in order to desalinize radioactivity-contaminated concrete. This method does desalinization by grinding the radioactivity-contaminated area of the concrete surface with desalinization equipment, which enables a near-to-perfect desalinization for relatively thinly contaminated surface. Likewise, this research verified the degree of desalinization by applying the grinding method and comparing it to the fragmentizing-washing method, and attempted to find a method to desalinize uranium-contaminated gravels more effectively. In order to desalinize uranium-contaminated gravels more effectively and compare to the existing washing-desalinization method, we conducted a desalinization experiment with grinding method that grinds gravel surface. As a

  1. Development of an automatic smear sampler and a polymer film for surface radioactive contamination assay

    International Nuclear Information System (INIS)

    Seo, B.-K.; Lee, K.-W.; Woo, Z.-H.; Jeong, K.-S.; Oh, W.-Z.; Han, M.-J.

    2004-01-01

    Measurement of the surface contamination by an indirect method is subject to the various kinds of error according to the sampling person and needs much time and effort in the sampling and assay. In this research, an automatic smear sampler is developed. It improved efficiency for assay work of surface contamination level achieved periodically in a radiation controlled area. Using an automatic smear sampler developed, it is confirmed that radioactive contaminated materials are uniformly transferred to smear paper more than any sampling method by an operator. Also, Solid scintillation proximity membranes were prepared for measuring the amount of radioactive contamination in laboratories contaminated by the low energy beta-ray emitter, such as 3 H and 14 C. Polysulfone scintillation proximity membranes were prepared by impregnating Cerium Activated Yttrium Silicate (CAYS), an inorganic fluor, in a membrane structure. The inorganic fluor-impregnated membranes were applied to detect the radioactive surface contamination. The preparation of membranes was divided into two processes. A supporting polymer film was made of casting solutions consisting of polysulfone and solvent, their cast film being solidified by vacuum evaporation. CAYS-dispersed polymer solutions were cast over the first, solidified polymer films and coagulated either by evaporating solvent in the solution with non-solvent in a coagulation bath. The prepared membranes had two distinguished, but tightly attached, double layers : one is the supporting layer of dense polymer film and the other results revealed that the prepared membranes were efficient to monitor radioactive contamination with reliable counting ability. For enhancement of pick-up and measurement efficiency, the membrane was prepared with the condition of different membrane solidification. The scintillation produced by interaction with radiation and CAYS was measured with photomultiplier tube. The test results showed that the prepared

  2. Contamination levels of domestic water sources in Maiduguri ...

    African Journals Online (AJOL)

    The study examines the levels of contamination of domestic water sources in Maiduguri Metropolis area of Borno State based on their physicochemical and bacteriological properties. It was informed by the global concern on good drinking water quality which is an indicator of development level; hence the focus on domestic ...

  3. Surface contamination of hazardous drug pharmacy storage bins and pharmacy distributor shipping containers.

    Science.gov (United States)

    Redic, Kimberly A; Fang, Kayleen; Christen, Catherine; Chaffee, Bruce W

    2018-03-01

    Purpose This study was conducted to determine whether there is contamination on exterior drug packaging using shipping totes from the distributor and carousel storage bins as surrogate markers of external packaging contamination. Methods A two-part study was conducted to measure the presence of 5-fluorouracil, ifosfamide, cyclophosphamide, docetaxel and paclitaxel using surrogate markers for external drug packaging. In Part I, 10 drug distributor shipping totes designated for transport of hazardous drugs provided a snapshot view of contamination from regular use and transit in and out of the pharmacy. An additional two totes designated for transport of non-hazardous drugs served as controls. In Part II, old carousel storage bins (i.e. those in use pre-study) were wiped for snapshot view of hazardous drug contamination on storage bins. New carousel storage bins were then put into use for storage of the five tested drugs and used for routine storage and inventory maintenance activities. Carousel bins were wiped at time intervals 0, 8, 16 and 52 weeks to measure surface contamination. Results Two of the 10 hazardous shipping totes were contaminated. Three of the five-old carousel bins were contaminated with cyclophosphamide. One of the old carousel bins was also contaminated with ifosfamide. There were no detectable levels of hazardous drugs on any of the new storage bins at time 0, 8 or 16 weeks. However, at the Week 52, there was a detectable level of 5-FU present in the 5-FU carousel bin. Conclusions Contamination of the surrogate markers suggests that external packaging for hazardous drugs is contaminated, either during the manufacturing process or during routine chain of custody activities. These results demonstrate that occupational exposure may occur due to contamination from shipping totes and storage bins, and that handling practices including use of personal protective equipment is warranted.

  4. Phytoextraction of low level U-contaminated soil

    International Nuclear Information System (INIS)

    Vandenhove, H.A.; Hees, M. van

    2002-01-01

    The nuclear fuel cycle may be a source of environmental contamination. Uranium exploitation produces large quantities of wastes but also accidental spills at nuclear fuel production, reprocessing or waste treatment plants have led to soil contamination with uranium. U-contaminated soil is generally excavated, packaged and removed which is a costly enterprise. Soil washing has also shown promising in removing U from contaminated soil, but results in the generation of liquid wastes and the deterioration of soil properties. In contrast, phytoextraction, the use of plants to remove contaminants from polluted soil, allows for in situ treatment and does not generate liquid wastes. Furthermore, the contaminated site is covered by plants during phytoextraction and wind and water erosion will be reduced. The phytoextraction potential depends on the amount of radionuclides extracted and the biomass produced. Hyper-accumulating plants often have a low biomass production. Moreover, uranium soil-to-plant transfer factors (TF: ratio of U concentration in dry plant tissue to concentration in soil) rarely exceed a value of 0.1 gg -1 . With a TF of 0.1 gg -1 and a biomass yield of 15t dry weigh ha -1 only 0.1% of the soil uranium will be annually immobilised in the plant biomass. These figures clearly show that the phytoextraction option is not a feasible remediation option, unless the uranium bioavailability could be drastically increased. It was shown that citric acid addition to highly contaminated U contaminated soil increased the U-accumulation of Brassica juncea 1000-fold. The objective of the present paper is to find out if low level U contaminated soil can be phytoextracted in order to achieve proposed release limits

  5. Reactor surface contamination stabilization. Innovative technology summary report

    International Nuclear Information System (INIS)

    1998-11-01

    Contaminated surfaces, such as the face of a nuclear reactor, need to be stabilized (fixed) to avoid airborne contamination during decontamination and decommissioning activities, and to prepare for interim safe storage. The traditional (baseline) method of fixing the contamination has been to spray a coating on the surfaces, but ensuring complete coverage over complex shapes, such as nozzles and hoses, is difficult. The Hanford Site C Reactor Technology Demonstration Group demonstrated innovative technologies to assess stabilization properties of various coatings and to achieve complete coverage of complex surfaces on the reactor face. This demonstration was conducted in two phases: the first phase consisted of a series of laboratory assessments of various stabilization coatings on metal coupons. For the second phase, coatings that passed the laboratory tests were applied to the front face of the C Reactor and evaluated. The baseline coating (Rust-Oleum No. 769) and one of the innovative technologies did not completely cover nozzle assemblies on the reactor face, the most critical of the second-phase evaluation criteria. However, one of the innovative coating systems, consisting of a base layer of foam covered by an outer layer of a polymeric film, was successful. The baseline technology would cost approximately 33% as much as the innovative technology cost of $64,000 to stabilize an entire reactor face (196 m 2 or 2116 ft 2 ) with 2,004 nozzle assemblies, but the baseline system failed to provide complete surface coverage

  6. Environmental contaminants of emerging concern in seafood--European database on contaminant levels.

    Science.gov (United States)

    Vandermeersch, Griet; Lourenço, Helena Maria; Alvarez-Muñoz, Diana; Cunha, Sara; Diogène, Jorge; Cano-Sancho, German; Sloth, Jens J; Kwadijk, Christiaan; Barcelo, Damia; Allegaert, Wim; Bekaert, Karen; Fernandes, José Oliveira; Marques, Antonio; Robbens, Johan

    2015-11-01

    Marine pollution gives rise to concern not only about the environment itself but also about the impact on food safety and consequently on public health. European authorities and consumers have therefore become increasingly worried about the transfer of contaminants from the marine environment to seafood. So-called "contaminants of emerging concern" are chemical substances for which no maximum levels have been laid down in EU legislation, or substances for which maximum levels have been provided but which require revision. Adequate information on their presence in seafood is often lacking and thus potential risks cannot be excluded. Assessment of food safety issues related to these contaminants has thus become urgent and imperative. A database (www.ecsafeseafooddbase.eu), containing available information on the levels of contaminants of emerging concern in seafood and providing the most recent data to scientists and regulatory authorities, was developed. The present paper reviews a selection of contaminants of emerging concern in seafood including toxic elements, endocrine disruptors, brominated flame retardants, pharmaceuticals and personal care products, polycyclic aromatic hydrocarbons and derivatives, microplastics and marine toxins. Current status on the knowledge of human exposure, toxicity and legislation are briefly presented and the outcome from scientific publications reporting on the levels of these compounds in seafood is presented and discussed. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Comparison of contaminants from different trophic levels and ecosystems

    DEFF Research Database (Denmark)

    Dietz, R.; Riget, F.; Cleemann, M.

    2000-01-01

    The present paper provides an overview of the priority contaminants and media from the Greenland part of the Arctic Monitoring and Assessment Program. Levels and accumulation patterns of heavy metals, POPs and a radionuclide (Cs-137) are compared from the terrestrial, freshwater and marine...... ecosystems. Of the nine compounds presented, seven (Cd, Hg, Se, Sigma PCB, Sigma DDT, Sigma HCH, HCB) increased in concentration towards higher trophic levels. For these contaminants the concentrations in soil and aquatic sediment were in the same order of magnitude, whereas the concentrations in marine...

  8. Removable coating for contamination protection of concrete surface

    International Nuclear Information System (INIS)

    Brambilla, G.; Beaulardi, L.

    1985-01-01

    In order to research protective coatings for concrete surfaces, assuring an effective protection against contamination and that it be easily removed before dismantling the structures, commercial stripping paints have been characterized for their conventional and nuclear properties: water and chemicals, abrasion, impact, tensile stress resistance, stripping capacity, decontaminability. The protective power of the coatings against contamination has been checked by recording the surface activity before and after stripping the paint film: the activity filtered through the coating was, in any case, very low (< 1% of the deposited activity). Indications from large scale application of a stripping paint in NUCLEO (Rome) establishments and technical evaluation of the possible utilization of removable coatings in the CAORSO Nuclear Power Station, are also reported

  9. Application Of The SPV-based Surface Lifetime Technique To In-Line Monitoring Of Surface Cu Contamination

    Science.gov (United States)

    D'Amico, John; Savtchouk, Alexandre; Wilson, Matthew; Kim, Chul Hong; Yoo, Hyung Won; Lee, Chang Hwan; Kim, Tae Kyoung; Son, Sang Hoon

    2009-09-01

    Implementation of Cu interconnects into Silicon Integrated Circuits (IC's) has been instrumental in the continuing improvement of IC device performance. Copper as a well known Gate Oxide Integrity (GOI) killer [1, 2] requires extensive protocols to minimize the possibility of cross contamination. Despite such protocols the risk for cross contamination exists, and consequently there is the need for in-line Cu cross-contamination detection metrology. Preferably the metrology will be non-destructive, fast, and capable of mapping on product wafers. Up to now the most common approaches for monitoring Cu contamination in IC fabrication lines either measure Cu in the bulk Si, which is not applicable to Cu cross-contamination monitoring because Back-End-of-the-Line thermal budgets restrict the ability to diffuse the surface Cu into the bulk Si; or the techniques are not optimal for in-line monitoring due to their destructive, time-consuming, or costly nature. In this work we demonstrate for the first time the application of the ac-Surface Photo Voltage (ac-SPV) surface lifetime approach [3] to in-line, full wafer coverage mapping of low level (metrology system. Furthermore, because the metrology is non-contact (utilizing edge-grip handling) and non-destructive, it is directly applicable to measurement of production wafers. In-line fab data acquired using this metrology is presented and compared to data from Inductively Coupled Plasma Mass Spectroscopy (ICP-MS).

  10. Calibration and verification of surface contamination meters --- Procedures and techniques

    International Nuclear Information System (INIS)

    Schuler, C; Butterweck, G.; Wernli, C.; Bochud, F.; Valley, J.-F.

    2007-03-01

    A standardised measurement procedure for surface contamination meters (SCM) is presented. The procedure aims at rendering surface contamination measurements to be simply and safely interpretable. Essential for the approach is the introduction and common use of the radionuclide specific quantity 'guideline value' specified in the Swiss Radiation Protection Ordinance as unit for the measurement of surface activity. The according radionuclide specific 'guideline value count rate' can be summarized as verification reference value for a group of radionuclides ('basis guideline value count rate'). The concept can be generalized for SCM of the same type or for SCM of different types using he same principle of detection. A SCM multi source calibration technique is applied for the determination of the instrument efficiency. Four different electron radiation energy regions, four different photon radiation energy regions and an alpha radiation energy region are represented by a set of calibration sources built according to ISO standard 8769-2. A guideline value count rate representing the activity per unit area of a surface contamination of one guideline value can be calculated for any radionuclide using instrument efficiency, radionuclide decay data, contamination source efficiency, guideline value averaging area (100 cm 2 ), and radionuclide specific guideline value. n this way, instrument responses for the evaluation of surface contaminations are obtained for radionuclides without available calibration sources as well as for short-Iived radionuclides, for which the continuous replacement of certified calibration sources can lead to unreasonable costs. SCM verification is based on surface emission rates of reference sources with an active area of 100 cm 2 . The verification for a given list of radionuclides is based on the radionuclide specific quantity guideline value count rate. Guideline value count rates for groups of radionuclides can be represented within the maximum

  11. Removal of Microbial Contamination from Surface by Plasma

    Science.gov (United States)

    Feng, Xinxin; Liu, Hongxia; Shen, Zhenxing; Wang, Taobo

    2018-01-01

    Microbial contamination is closely associated with human and environmental health, they can be tested on food surfaces, medical devices, packing material and so on. In this paper the removal of the microbial contamination from surface using plasma treatment is investigated. The Escherichia coli (E. coli) has been chosen as a bio-indicator enabling to evaluate the effect of plasma assisted microbial inactivation. Oxygen gas was as the working gas. The plasma RF power, plasma exposition time, gas flow and the concentration of organic pollutant were varied in order to see the effect of the plasma treatment on the Gram-negative germ removal. After the treatment, the microbial abatement was evaluated by the standard plate count method. This proved a positive effect of the plasma treatment on Gram-negative germ removal. The kinetics and mathematical model of removal were studied after plasma treatment, and then the removing course of E. coli was analyzed. This work is meaningful for deepening our understanding of the fundamental scientific principles regarding microbial contamination from surface by plasma.

  12. Verification of surface contamination density standard using clearance automatic laser inspection system for objects from a nuclear power plant

    International Nuclear Information System (INIS)

    Sasaki, Michiya; Ogino, Haruyuki; Ichiji, Takeshi; Hattori, Takatoshi

    2008-01-01

    In the clearance level inspection in Japan, it is necessary to indicate that the activity level of the target object must be less than not only the clearance levels, but also the surface contamination density standards. The classification measurements for these two standards have been performed separately, and the GM survey meters based on beta-ray measurement have mainly been used for surface contamination density measurement so far. Recently the Clearance Automatic Laser Inspection System, named CLALIS, has been developed to estimate the low-level activity concentration. This system consists of 3-dimensional laser scanner for shape measurement and eight large NE102A plastic scintillation detectors for gamma-ray measurement, and it has been clarified that the CLALIS has adequate detection ability for clearance measurement of both metal scraps and concrete debris. In this study, we compared the surface contamination densities for a number of actual contaminated and non-contaminated objects generated inside from the radiation controlled area at the Kashiwazaki-Kariwa nuclear power station by using the CLALIS and the GM survey meter. As a result, since CLALIS could detect the surface contamination as well as the GM survey meter for all measurement targets, it was revealed that CLALIS can rationally achieve clearance level inspection in a single radiation measurement. The practicality of CLALIS in view of the detection limit and processing time was discussed by comparison with the usual radiation monitors for surface contamination measurement. (author)

  13. Residual radioactive contamination from decommissioning: Technical basis for translating contamination levels to annual dose

    International Nuclear Information System (INIS)

    Kennedy, W.E. Jr.; Peloquin, R.A.

    1990-01-01

    This document describes the generic modeling of the total effective dose equivalent (TEDE) to an individual in a population from a unit concentration of residual radioactive contamination. Radioactive contamination inside buildings and soil contamination are considered. Unit concentration TEDE factors by radionuclide, exposure pathway, and exposure scenario are calculated. Reference radiation exposure scenarios are used to derive unit concentration TEDE factors for about 200 individual radionuclides and parent-daughter mixtures. For buildings, these unit concentration factors list the annual TEDE for volume and surface contamination situations. For soil, annual TEDE factors are presented for unit concentrations of radionuclides in soil during residential use of contaminated land and the TEDE per unit total inventory for potential use of drinking water from a ground-water source. Because of the generic treatment of potentially complex ground-water systems, the annual TEDE factors for drinking water for a given inventory may only indicate when additional site data or modeling sophistication are warranted. Descriptions are provided of the models, exposure pathways, exposure scenarios, parameter values, and assumptions used. An analysis of the potential annual TEDE resulting from reference mixtures of residual radionuclides is provided to demonstrate application of the TEDE factors. 62 refs., 5 figs., 66 tabs

  14. Comparison of trace element contamination levels (Cu, Zn, Fe, Cd ...

    African Journals Online (AJOL)

    Comparison of trace element contamination levels (Cu, Zn, Fe, Cd and Pb) in the soft tissues of the gastropods Tympanotonus fuscatus fuscatus and Tf radula collected in the Ebrié Lagoon (Côte d'Ivoire): Evidence of the risks linked to linked to lead and.

  15. Evaluation of the Level of air Microbial Contamination in some ...

    African Journals Online (AJOL)

    The level of air microbial contamination in some teaching hospitals waste dump site in South Eastern Nigeria was evaluated using the standard microbiological techniques. Passive air sampling was performed using settle plates. The microbial load of the air around the hospitals waste dumpsite, showed high microbial load ...

  16. Comparative study on the level of bacteriological contamination of ...

    African Journals Online (AJOL)

    Comparative study on the level of bacteriological contamination of automatic teller machines, public toilets and public transport commercial motorcycle crash ... Conclusion: This study has revealed the ability of these public devices to serve as vehicle of transmission of microorganisms with serious health implications.

  17. Analysis of body surface radiological contamination for inbound people from Japan to China during the Fukushima nuclear accident

    International Nuclear Information System (INIS)

    Yuan Long; Ma Weidong; Lei Cuiping; Chen Huifang; Li Yuwen; Liu Ying

    2012-01-01

    Objective: To investigate the radiological contamination of body surface for inbound people from Japan to China during Fukushima nuclear accident. Methods: According to The guidance for radiological contamination management for body surface issued by Chinese Center for Disease Control and Prevention, for people evacuated from Japan, the body surface monitoring of radiological contamination was performed by the related agencies in main provinces and cities in China. The monitoring data were collected, analyzed and reported to Ministry of Health. Results: A total of 432 persons were checked. The monitoring results of 429 cases were close to the background level, while those of three persons were higher than the background level. Conclusions: In general,the detected results were as low as the background level. The radiological contamination monitoring of body surface for people from Japan could provide scientific data to relax the horror and panic among them. (authors)

  18. Treatment of groundwater contaminated with low levels of military munitions

    International Nuclear Information System (INIS)

    Bricka, R.M.; Sharp, W.

    1993-01-01

    The site of interest is a military base that was established in the late 1800s. In its early history this facility was used as a powder depot to fill projectiles with miximite (a propellant). Since World War I, this facility was used to produce artillery ammunition, bombs, high explosives, pyrotechnics and other ordinances. Weapons production at this facility has ceased, but as a result of the past activities at this facility, contaminants are migrating into the groundwater. One source of drinking water for this installation is a screened well in a stratified-drift aquifer system at a depth of 75-85 feet below land surface. In the 1980s sampling of this well revealed low level contamination of trichloroethylene (TCE), RDX and HMX. TCE levels exceeded drinking water standards and an air stripping column was installed to remove the TCE. RDX and HMX, concentrations were below drinking water standards. Health Advisory (HA) levels for RDX and HMX were published by the U.S. Environmental Protection Agency (USEPA) in November 1988. The lifetime HA levels are 2 ppb and 400 ppb for RDX and HMX, respectively (McLellan et al. 1988a, and McLellan et al. 1988b). It is expected that continuous withdrawals from this well will increase RDX and HMX concentrations. In addition, it is believed that future USEPA regulations will adapt the HA as a drinking water standard. This study was initiated in an effort to have an appropriate cost effective technology ready to meet any such standard. RDX and HMX RDX and HMX are military explosives. RDX (Hexahydro-l,3,5-trinitro-l,3,5-triazine) is a code name for Research Department Explosive. This explosive is described as a white crystalline solid with about 1.3 times the explosive power of trinitrotoluene (TNT). RDX is classified as a EPA Group C compound: Possible Human Carcinogen (McLellan et. al. 1988a). HMX (Octahydro-1, 3, 5, 7- tetranitro-l, 3, 5, 7-tetrazocine) is a code name for High Melting Explosive. This explosive is described as a

  19. Explosive Contamination from Substrate Surfaces: Differences and Similarities in Contamination Techniques Using RDX and C-4

    Science.gov (United States)

    Miller, C. J.; Yoder, T. S.

    2010-06-01

    Explosive trace detection equipment has been deployed to airports for more than a decade. During this time, the need for standardized procedures and calibrated trace amounts for ensuring that the systems are operating properly and detecting the correct explosive has been apparent but a standard representative of a fingerprint has been elusive. Standards are also necessary to evaluate instrumentation in the laboratories during development and prior to deployment to determine sample throughput, probability of detection, false positive/negative rates, ease of use by operator, mechanical and/or software problems that may be encountered, and other pertinent parameters that would result in the equipment being unusable during field operations. Since many laboratories do not have access to nor are allowed to handle explosives, the equipment is tested using techniques aimed at simulating the actual explosives fingerprint. This laboratory study focused on examining the similarities and differences in three different surface contamination techniques that are used to performance test explosive trace detection equipment in an attempt to determine how effective the techniques are at replicating actual field samples and to offer scenarios where each contamination technique is applicable. The three techniques used were dry transfer deposition of standard solutions using the Transportation Security Laboratory’s (TSL) patented dry transfer techniques (US patent 6470730), direct deposition of explosive standards onto substrates, and fingerprinting of actual explosives onto substrates. RDX was deposited on the surface of one of five substrates using one of the three different deposition techniques. The process was repeated for each substrate type using each contamination technique. The substrate types used were: 50% cotton/50% polyester as found in T-shirts, 100% cotton with a smooth surface such as that found in a cotton dress shirt, 100% cotton on a rough surface such as that

  20. Residual viral and bacterial contamination of surfaces after cleaning and disinfection.

    Science.gov (United States)

    Tuladhar, Era; Hazeleger, Wilma C; Koopmans, Marion; Zwietering, Marcel H; Beumer, Rijkelt R; Duizer, Erwin

    2012-11-01

    Environmental surfaces contaminated with pathogens can be sources of indirect transmission, and cleaning and disinfection are common interventions focused on reducing contamination levels. We determined the efficacy of cleaning and disinfection procedures for reducing contamination by noroviruses, rotavirus, poliovirus, parechovirus, adenovirus, influenza virus, Staphylococcus aureus, and Salmonella enterica from artificially contaminated stainless steel surfaces. After a single wipe with water, liquid soap, or 250-ppm free chlorine solution, the numbers of infective viruses and bacteria were reduced by 1 log(10) for poliovirus and close to 4 log(10) for influenza virus. There was no significant difference in residual contamination levels after wiping with water, liquid soap, or 250-ppm chlorine solution. When a single wipe with liquid soap was followed by a second wipe using 250- or 1,000-ppm chlorine, an extra 1- to 3-log(10) reduction was achieved, and except for rotavirus and norovirus genogroup I, no significant additional effect of 1,000 ppm compared to 250 ppm was found. A reduced correlation between reduction in PCR units (PCRU) and reduction in infectious particles suggests that at least part of the reduction achieved in the second step is due to inactivation instead of removal alone. We used data on infectious doses and transfer efficiencies to estimate a target level to which the residual contamination should be reduced and found that a single wipe with liquid soap followed by a wipe with 250-ppm free chlorine solution was sufficient to reduce the residual contamination to below the target level for most of the pathogens tested.

  1. Chemometric Analysis of Selected Organic Contaminants in Surface Water of Langat River Basin

    International Nuclear Information System (INIS)

    Mohamad Rafaie Mohamed Zubir; Rozita Osman; Norashikin Saim

    2016-01-01

    Chemometric techniques namely hierarchical agglomerative cluster analysis (HACA), discriminant analysis (DA), principal component analysis (PCA) and factor analysis (FA) were applied to the distribution of selected organic contaminants (polycyclic aromatic hydrocarbons (PAHs), sterols, pesticides (chloropyrifos), and phenol) to assess the potential of using these organic contaminants as chemical markers in Langat River Basin. Water samples were collected from February 2012 to January 2013 on a monthly basis for nine monitoring sites along Langat River Basin. HACA was able to classify the sampling sites into three clusters which can be correlated to the level of contamination (low, moderate and high contamination sites). DA was used to discriminate the sources of contamination using the selected organic contaminants and relate to the existing DOE local activities groupings. Forward and backward stepwise DA was able to discriminate two and five organic contaminants variables, respectively, from the original 13 selected variables. The five significant variables identified using backward stepwise DA were fluorene, pyrene, stigmastanol, stigmasterol and phenol. PCA and FA (varimax functionality) were used to identify the possible sources of each organic contaminant based on the inventory of local activities. Five principal components were obtained with 66.5 % of the total variation. Result from FA indicated that PAHs (pyrene, fluorene, acenaphthene, benzo[a]anthracene) originated from industrial activity and socio-economic activities; while sterols (coprostanol, stigmastanol and stigmasterol) were associated to domestic sewage and local socio-economic activities. The occurrence of chloropyrifos was correlated to agricultural activities, urban and domestic discharges. This study showed that the application of chemometrics on the distribution of selected organic contaminants was able to trace the sources of contamination in surface water. (author)

  2. Allowable residual-contamination levels for decommissioning facilities in the 100 areas of the Hanford Site

    International Nuclear Information System (INIS)

    Kennedy, W.E. Jr.; Napier, B.A.

    1983-07-01

    This report contains the results of a study sponsored by UNC Nuclear Industries to determine Allowable Residual Contamination Levels (ARCL) for five generic categories of facilities in the 100 Areas of the Hanford Site. The purpose of this study is to provide ARCL data useful to UNC engineers in conducting safety and cost comparisons for decommissioning alternatives. The ARCL results are based on a scenario/exposure-pathway analysis and compliance with an annual dose limit for three specific modes of future use of the land and facilities. These modes of use are restricted, controlled, and unrestricted. The information on ARCL values for restricted and controlled use provided by this report is intended to permit a full consideration of decommissioning alternatives. ARCL results are presented both for surface contamination remaining in facilities (in dpm/100 cm 2 ), and for unconfined surface and confined subsurface soil conditions (in pCi/g). Two confined soil conditions are considered: contamination at depths between 1 and 4 m, and contamination at depths greater than or equal to 5 m. A set of worksheets are presented in an appendix for modifying the ARCL values to accommodate changes in the radionuclide mixture or concentrations, to consider the impacts of radioactive decay, and to predict instrument responses. Finally, a comparison is made between the unrestricted release ARCL values for the 100 Area facilities and existing decommissioning and land disposal regulations. For surface contamination, the comparison shows good agreement. For soil contamination, the comparison shows good agreement if reasonable modification factors are applied to account for the differences in modeling soil contamination and licensed low-level waste

  3. Radiation Level Changes at RAM Package Surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Opperman, Erich [Washington Savannah River Company; Hawk, Mark B [ORNL; Kapoor, Ashok [U.S. Department of Energy, Office of Packaging and Transportation; Natali, Ronald [R. B. Natali Consulting, Inc.

    2010-01-01

    This paper will explore design considerations required to meet the regulations that limit radiation level variations at external surfaces of radioactive material (RAM) packages. The radiation level requirements at package surfaces (e.g. TS-R-1 paragraphs 531 and 646) invoke not only maximum radiation levels, but also strict limits on the allowable increase in the radiation level during transport. This paper will explore the regulatory requirements by quantifying the amount of near surface movement and/or payload shifting that results in a 20% increase in the radiation level at the package surface. Typical IP-2, IP-3, Type A and Type B packaging and source geometries will be illustrated. Variations in surface radiation levels are typically the result of changes in the geometry of the surface due to an impact, puncture or crush event, or shifting and settling of radioactive contents.

  4. A decision-making process on cleanup of contaminated surface soil

    International Nuclear Information System (INIS)

    Yasuda, Hiroshi

    1996-01-01

    This study presents principles for determining derived intervention levels (DILs) for surface soil cleanup. The people concerned were divided into major three groups: residents, responsible parties, and cleanup workers; it was considered that each group has different interests. The DILs for soil cleanup were determined from the viewpoints of these three groups: safety of residence, advantages of the countermeasures, and safety of cleanup activities, respectively. An example process for determination of the DILs in accordance with the principles was also presented for a site contaminated by 137 Cs. This decision-making frame is expected to be applicable to other contaminants. (author)

  5. Levels and trends of radioactive contaminants in the Greenland environment

    DEFF Research Database (Denmark)

    Dahlgaard, H.; Eriksson, M.; Nielsen, S.P.

    2004-01-01

    . The concentrations are expected to increase in the future, especially in East Greenland. The Bylot Sound at the Thule Airbase (Pituffik) in North-West Greenland was contaminated with plutonium and enriched uranium in a weapons accident in 1968. Biological activity has mixed accident plutonium efficiently...... into the new sediments resulting in continued high surface sediment concentrations three decades after the accident. Transfer of plutonium to benthic biota is low-and lower than observed in the Irish Sea. This is supposed to be caused by the physico-chemical form of the accident plutonium. A recent study...

  6. Bacteria contamination of touch surfaces in Polish hospital wards

    Directory of Open Access Journals (Sweden)

    Anna Różańska

    2017-08-01

    Full Text Available Background: The objective of the study has been to evaluate the pathogenic bacteria contamination of touch surfaces in hospital wards. Material and Methods: Samples were taken from frequently touched surfaces in the hospital environment in 13 units of various types. Culturing was carried out on solid blood agar and in growth broth (tryptic soy broth – TSB. Species identification was performed using the analytical profile index (API biochemical testing and confirmed with matrix assisted laser desorption ionization time-flight mass spectrometry (MALDI-TOF-MS system. Results: The total of 161 samples were taken for the study. Fifty-two of them, after 24 h of culture on a solid medium, demonstrated bacterial growth and further 60 samples had growth after prior multiplication in TSB. Overall, 69.6% of samples exhibited growth of 19 bacterial species. Pathogenic species – representing indicator organisms of efficiency of hospital cleaning – was demonstrated by 21.4% of samples. Among them Acinetobacter spp., Enterocococci spp. and Staphylococcus aureus were identified. Coagulase-negative staphylococci (CNS were predominant. The proportion of various groups of bacteria significantly varied in respective hospitals, and in various types of wards. Disturbing observation is a large proportion of resistance of isolated CNS strains as a potential reservoir of resistance genes. Conclusions: The results show that touch surfaces in hospital units are contaminated by both potentially pathogenic and pathogenic bacterial species. In connection with the reported, also in Poland, frequent omission or incorrect execution of hand hygiene by hospital staff, and probably patients, touch surfaces still constitute important reservoir of pathogenic bacteria. Improving hand hygiene compliance of health-care workers with recommendations is necessary for increasing biological safety of hospital environment. Med Pr 2017;68(3:459–467

  7. Determination of the external contamination and cross-contamination by cytotoxic drugs on the surfaces of vials available on the Swiss market.

    Science.gov (United States)

    Fleury-Souverain, Sandrine; Nussbaumer, Susanne; Mattiuzzo, Marc; Bonnabry, Pascal

    2014-04-01

    The external contamination and cross-contamination by cytotoxic drugs on the surface (outside and septum) of 133 vials from various manufacturers and available on the Swiss market were evaluated. All of the tested vials contained one of the following active ingredients: cyclophosphamide, cytarabine, doxorubicin, epirubicin, etoposide phosphate, gemcitabine, ifosfamide, irinotecan, methotrexate or vincristine. The validated wiping liquid chromatography-mass spectrometry method used in this study allowed for the simultaneous determination of these 10 cytotoxic drugs in less than 30 min. External contamination by cytotoxic drugs was detected on 63% of tested vials (outside and septum). The highest contamination level was observed on etoposide phosphate vials with 1896.66 ng of active ingredient on the outside of the vial. Approximately 20% of the contaminated vials had greater than 10 ng of cytotoxic drugs. Chemical contamination on the septum was detected on 38% of the vials. No contamination or very low levels of cytotoxic drugs, less than 1 ng per vial, were detected on the vials protected by plastic shrink-wrap. Traces of cytotoxic drugs different from the active ingredient were detected on 35% of the tested vials. Handling cytotoxic vials with gloves and having a procedure for the decontamination of vials are of the utmost importance for reducing exposure to cytotoxic drugs. Moreover, manufacturers must improve their procedures to provide products free from any contamination.

  8. Skin and surface lead contamination, hygiene programs, and work practices of bridge surface preparation and painting contractors.

    Science.gov (United States)

    Virji, M Abbas; Woskie, Susan R; Pepper, Lewis D

    2009-02-01

    A 2005 regulatory review of the lead in construction standard by the Occupational Safety and Health Administration (OSHA) noted that alternative pathways of exposure can be as significant as inhalation exposure and that noncompliance with the standard pertaining to hygiene facilities and practices was the second most commonly violated section of the standard. Noncompliance with provisions of the standard and unhealthy work and hygiene practices likely increase the likelihood of take-home lead via contaminated clothing, automobiles, and skin, thus contributing to elevated blood lead levels (BLL) among construction workers and their family members. We performed a cross-sectional study of bridge painters working for small contractors in Massachusetts to investigate causes of persistent elevated BLLs and to assess lead exposures. Thirteen work sites were evaluated for a 2-week period during which surface and skin wipe samples were collected and qualitative information was obtained on personal hygiene practices, decontamination and hand wash facilities, and respiratory protection programs. Results showed lead contamination on workers' skin, respirators, personal automobiles, and the decontamination unit, indicating a significant potential for take-home lead exposure. Overall, the geometric mean (GM) skin lead levels ranged from 373 microg on workers' faces at end of shift to 814 microg on hands at break time. The overall GM lead level inside respirators was 143 microg before work and 286 microg after work. Lead contamination was also present inside workers' personal vehicles as well as on surfaces inside the clean side of the decontamination unit. Review of the respiratory protection programs, work site decontamination and hand wash facilities, and personal hygiene practices indicated that these factors had significant impact on skin and surface contamination levels and identified significant opportunities for improving work site facilities and personal practices

  9. Surface Contaminant Control Technologies to Improve Laser Damage Resistance of Optics

    Directory of Open Access Journals (Sweden)

    Xiaofeng Cheng

    2014-01-01

    Full Text Available The large high-power solid lasers, such as the National Ignition Facility (NIF of America and the Shenguang-III (SG-III laser facility of China, can output over 2.1 MJ laser pulse for the inertial confinement fusion (ICF experiments. Because of the enhancement of operating flux and the expansion of laser driver scale, the problem of contamination seriously influences their construction period and operation life. During irradiation by intense laser beams, the contaminants on the metallic surface of beam tubes can be transmitted to the optical surfaces and lead to damage of optical components. For the high-power solid-state laser facilities, contamination control focuses on the slab amplifiers, spatial filters, and final-optical assemblies. In this paper, an effective solution to control contaminations including the whole process of the laser driver is put forward to provide the safe operation of laser facilities, and the detailed technical methods of contamination control such as washing, cleanliness metrology, and cleanliness protecting are also introduced to reduce the probability of laser-induced damage of optics. The experimental results show that the cleanliness level of SG-III laser facility is much better to ensure that the laser facility can safely operate at high energy flux.

  10. Levels of chemical contaminants in nonoccupationally exposed U. S. residents

    Energy Technology Data Exchange (ETDEWEB)

    Holleman, J.W.; Hammons, A.S.

    1978-08-01

    Data are presented on the levels of all chemical contaminants resulting from environmental pollution which have been found in human tissues including blood, urine, breast milk, and tissue samples obtained at autopsy. Most data results from specific surveys to determine health hazards. The roles of trace elements and recognition of the need to determine baseline levels of chemicals introduced into the environment are factors which have motivated surveys by individual investigators. Thus, most data on chemicals in human tissues record levels of pesticides (e.g., DDT and metabolites), levels of trace metals such as lead, cadmium, and mercury, or levels of nutritionally essential elements such as zinc, copper, manganese, and fluoride. Data available on iron and calcium are not presented as their presence in the environment is generally not considered hazardous. Data on several uncommon chemicals, such as indium and ytterbium, are included basically as items of interest and to further document their presence in healthy individuals. Baseline data were presented where available to provide perspective as to chemical levels which might be expected under conditions where exposure could be considered normal or not directly related to a pollutant source. Nearly 600 cited surveys or investigations, most of which were reported within the past decade, are listed. Ninety-four different chemical contaminants, primarily trace metals and organochlorine pesticides, are reported. It is estimated that over 75% of the data published during the past 30 years on chemical contaminants derived from environmental pollution and found in human tissue in the United States are represented in this report.

  11. Radiocesium levels in vegetation colonizing a contaminated floodplain

    International Nuclear Information System (INIS)

    Garten, C.T. Jr.; Briese, L.A.; Geiger, R.A.; Sharitz, R.; Smith, M.H.

    1975-01-01

    Radiocesium concentrations in herbaceous and woody plants inhabiting a floodplain contaminated by nuclear production reactor effluents were measured. Leaves and stems of herbaceous plants (Andropogon sp. and Scirpus cyperinus) contained higher concentrations of radiocesium than those of woody plants (Alnus serrulata, Myrica cerifera, and Salix nigra). Andropogon and Alnus fruits had higher concentrations than the leaves or stems. Radiocesium concentrations in fruits and leaves were significantly correlated with stem radiocesium levels in some or all of the species sampled. Mean radiocesium levels in the plant parts exceeded mean soil concentrations; this indicates concentration of radiocesium by the vegetation

  12. Present level of contaminants in the Romanian Black Sea sector

    International Nuclear Information System (INIS)

    Bologa, A.S.; Apas, M.; Cociasu, A.; Cuingioglu, E.; Patrascu, V.; Pecheanu, I.; Piescu, V.; Popa, L.

    1999-01-01

    The assessment of environmental quality in the Romanian Black Sea sector is being constantly made by the Romanian Marine Research Institute (RMRI) within the National Integrated Monitoring System. The contamination of the marine environment is expressed by considering four chemical and a biological parameter: nutrients (N-NO 2 , N-NO 3 , N-NH 4 , P-PO 4 , organic P, Si-SiO 4 ), heavy metals (Mn, Fe, Cu, Cd, Pb), artificial radionuclides ( 90 Sr, 137 Cs), total hydrocarbons, parasite and saprophyte fungi in sediments, sea water and/or biota. Present levels of contaminants are discussed as to their historical evolution during the last few years or decades. Inorganic N and P concentrations still exceed three to five times those before eutrophication started to intensify in the early '70s. Practical uses of results by national and regional authorities are discussed. (author)

  13. Comparison of contaminants from different trophic levels and ecosystems

    Energy Technology Data Exchange (ETDEWEB)

    Dietz, R.; Riget, F. [Department of Arctic Environment, Ministry of Environment and Energy, National Environmental Research Institute, Tagensvej 135, 4 floor, DK-2200 Copenhagen (Denmark); Cleemann, M. [Department of Environmental Chemistry, Ministry of Environment and Energy, National Environmental Research Institute, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Aarkrog, A. [Risoe National Laboratory, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Johansen, P. [Department of Arctic Environment, Ministry of Environment and Energy, National Environmental Research Institute, Tagensvej 135, 4 floor, DK-2200 Copenhagen (Denmark); Hansen, J.C. [Risoe National Laboratory, Frederiksborgvej 399, DK-4000 Roskilde (Denmark)

    2000-01-17

    The present paper provides an overview of the priority contaminants and media from the Greenland part of the Arctic Monitoring and Assessment Program. Levels and accumulation patterns of heavy metals, POPs and a radionuclide (137Cs) are compared from the terrestrial, freshwater and marine ecosystems. Of the nine compounds presented, seven (Cd, Hg, Se, {sigma}PCB, {sigma}DDT, {sigma}HCH, HCB) increased in concentration towards higher trophic levels. For these contaminants the concentrations in soil and aquatic sediment were in the same order of magnitude, whereas the concentrations in marine biota were higher than found in the freshwater and terrestrial ecosystems probably due to the presence of longer food chains. Pb and 137Cs showed the reverse pattern compared with the other compounds. The concentrations in soil and aquatic sediments decreased in the order terrestrial, freshwater and marine ecosystems, which was reflected in the biota as well. Reindeer had similar or lower levels of Pb and 137Cs than lichens. Levels of Pb and 137Cs in marine biota did not show the same clear increase towards higher trophic as found for the other analysed compounds. Greenland Inuit contains considerably less mercury but higher levels of {sigma}PCB, {sigma}DDT and HCB than other Arctic marine top consumers.

  14. Recommendations for determining the surface contamination of the skin and estimating radiation exposure of the skin after contamination

    International Nuclear Information System (INIS)

    1989-01-01

    The recommendations are applicable to the determination of surface contaminations of the skin and to the estimation of the expected radiation exposure of the skin of contaminated persons. According to the present recommendations, the radiation exposure can only be estimated for the intact and healthy skin

  15. Contaminants of emerging concern in surface waters in Barbados, West Indies.

    Science.gov (United States)

    Edwards, Quincy A; Kulikov, Sergei M; Garner-O'Neale, Leah D; Metcalfe, Chris D; Sultana, Tamanna

    2017-11-14

    Contaminants of emerging concern (CECs), including pharmaceuticals, artificial sweeteners, steroid hormones, and current-use pesticides have been detected in surface waters around the world, but to date, there have been no reports in the peer-reviewed literature on the levels of these classes of contaminants in freshwater resources in the Caribbean region. In the present study, multi-residue solid phase extraction (SPE) and liquid chromatography with tandem mass spectroscopy (LC-MS/MS) were used to analyze grab samples of surface waters collected from five different watersheds in Barbados, West Indies. The artificial sweeteners (AS), acesulfame, cyclamate, saccharin, and sucralose were widely detected in the watersheds, indicating contamination from domestic wastewater, and the concentrations of these chemical tracers in water were correlated with the concentrations of the non-prescription pharmaceutical, ibuprofen (R 2 values of 0.4-0.6). Surprisingly, the concentrations of another chemical tracer of domestic wastewater, caffeine were not correlated with ibuprofen or AS concentrations. Several other prescription pharmaceuticals and the steroid hormones, estrone and androstenedione, were detected in selected watersheds at low ng/L concentrations. The fungicide, chlorothalonil was widely detected in surface waters at low (contamination of water resources by pharmaceuticals.

  16. Camel meat quality in the slaughterhouse of Ouargla in Algeria. II. Bacterial surface contamination of carcasses

    Directory of Open Access Journals (Sweden)

    A. Benaissa

    2015-10-01

    Full Text Available To assess the microbiological quality of camel meat in the slaughterhouse of Ouargla District in Algeria, the bacterial surface contamination of 60 camel carcasses was investigated. Within an hour after slaughter, swabs were used to collect samples on three sites (thigh, flank and shoulder, just after skinning and before postmortem inspection. Germ rates varied depending on the carcasses and sampling sites. The predominant flora was the total aerobic mesophilic flora, whose contamination level was 2.8  log CFU/cm2 (i.e. 25% of the flora count, followed by enterobacteria with 2.4 log CFU/cm2 (21%, total coliforms with 2.2 log CFU/cm2 (20%, fecal coliforms with 2.0  log CFU/cm2 (18%, and staphylococci with 1.8 log CFU/cm2 (16%. Salmonella and Escherichia coli were detected on all the sampled sites of the carcasses. The camel meat of Ouargla slaughterhouse showed a high level of contamination by pathogenic bacteria (salmonellae and staphylococci. A high fecal contamination (E. coli was also present. Good hygiene practices need to be implemented at slaughter to reduce contaminations.

  17. Effect of Surface Contaminants Remained on the Blasted Surface on Epoxy Coating Performance and Corrosion Resistance

    International Nuclear Information System (INIS)

    Baek, Kwang Ki; Park, Chung Seo; Kim, Ki Hong; Chung, Mong Kyu; Park, Jin Hwan

    2006-01-01

    One of the critical issues in the coating specification is the allowable limit of surface contaminant(s) - such as soluble salt(s), grit dust, and rust - after grit blasting. Yet, there is no universally accepted data supporting the relationship between the long-term coating performance and the amount of various surface contaminants allowed after grit blasting. In this study, it was attempted to prepare epoxy coatings applied on grit-blasted steel substrate dosed with controlled amount of surface contaminants - such as soluble salt(s), grit dust, and rust. Then, coating samples were subjected to 4,200 hours of cyclic test(NORSOK M-501), which were then evaluated in terms of resistance to rust creepage, blistering, chalking, rusting, cracking and adhesion strength. Additional investigations on the possible damage at the paint/steel interface were carried out using an Electrochemical Impedance Spectroscopy(EIS) and observations of under-film-corrosion. Test results suggested that the current industrial specifications were well matched with the allowable degree of rust, whereas the allowable amount of soluble salt and grit dust after grit blasting showed a certain deviation from the specifications currently employed for fabrication of marine vessels and offshore facilities

  18. Conformation evolution of oil contaminants onto aluminum oxide surface in aqueous solution: The effect of surface coverage

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Wenkun; Liu, Haitao, E-mail: xwk584523412@126.com; Sun, Yazhou; Fu, Hongya; Liang, Yingchun

    2017-01-15

    Highlights: • The dynamic conformational change of oil contaminations, at various surface coverages onto perfect α-Al{sub 2}O{sub 3}(0001) surface in aqueous solution is given. • The effect of surface coverage of oil molecules on the driving forces for the conformational change of oil contaminations is described. • The effect of interfacial water on the conformational change and even detachment of oil contaminations is considered. - Abstract: The microscopic conformational change process of oil contaminants adhered onto perfect α-Al{sub 2}O{sub 3} (0001) surface in aqueous solution was investigated by using all-atom classic molecular dynamics simulations. The change in removal mechanism of oil contaminants induced by surface coverage (surface area per molecule) was emphatically explored. Our simulation results strongly reveal that the increase in oil surface coverage induces an evident difference in microscopic detachment processes of oil contaminants. At a low surface coverage, oil contaminants can be thoroughly detached from solid surface. The whole detachment process could be divided into multi stages, including conformational change of oil contaminants on solid surface, dynamic motion of those in bulk solution and rapid migration of those from bulk solution to air/water interface. With surface coverage increasing, water diffusion becomes the key to induce conformational change and promote the detachment of oil contaminants. When oil surface coverage exceeds a threshold value, oil contaminants also undertake an evident conformational change process exhibiting typical characteristics but an incomplete detachment process occurs. All findings of the present study are helpful for the interpretation of the removal mechanism of oil contaminants on solid surface.

  19. Listeria monocytogenes in Fresh Produce: Outbreaks, Prevalence and Contamination Levels

    Directory of Open Access Journals (Sweden)

    Qi Zhu

    2017-03-01

    Full Text Available Listeria monocytogenes, a member of the genus Listeria, is widely distributed in agricultural environments, such as soil, manure and water. This organism is a recognized foodborne pathogenic bacterium that causes many diseases, from mild gastroenteritis to severe blood and/or central nervous system infections, as well as abortion in pregnant women. Generally, processed ready-to-eat and cold-stored meat and dairy products are considered high-risk foods for L. monocytogenes infections that cause human illness (listeriosis. However, recently, several listeriosis outbreaks have been linked to fresh produce contamination around the world. Additionally, many studies have detected L. monocytogenes in fresh produce samples and even in some minimally processed vegetables. Thus L. monocytogenes may contaminate fresh produce if present in the growing environment (soil and water. Prevention of biofilm formation is an important control measure to reduce the prevalence and survival of L. monocytogenes in growing environments and on fresh produce. This article specifically focuses on fresh produce–associated listeriosis outbreaks, prevalence in growing environments, contamination levels of fresh produce, and associated fresh produce safety challenges.

  20. MULTIPLE IMAGING TECHNIQUES DEMONSTRATE THE MANIPULATION OF SURFACES TO REDUCE BACTERIAL CONTAMINATION

    Science.gov (United States)

    Surface imaging techniques were combined to determine appropriate manipulation of technologically important surfaces for commercial applications. Stainless steel surfaces were engineered to reduce bacterial contamination, biofilm formation, and corrosion during product processing...

  1. Potential effects of groundwater and surface water contamination in an urban area, Qus City, Upper Egypt

    Science.gov (United States)

    Abdalla, Fathy; Khalil, Ramadan

    2018-05-01

    The potential effects of anthropogenic activities, in particular, unsafe sewage disposal practices, on shallow groundwater in an unconfined aquifer and on surface water were evaluated within an urban area by the use of hydrogeological, hydrochemical, and bacteriological analyses. Physicochemical and bacteriological data was obtained from forty-five sampling points based on33 groundwater samples from variable depths and 12 surface water samples. The pollution sources are related to raw sewage and wastewater discharges, agricultural runoff, and wastewater from the nearby Paper Factory. Out of the 33 groundwater samples studied, 17 had significant concentrations of NO3-, Cl- and SO42-, and high bacteria counts. Most of the water samples from the wells contained high Fe, Mn, Pb, Zn, Cd, and Cr. The majority of surface water samples presented high NO3- concentrations and high bacteria counts. A scatter plot of HCO3- versus Ca indicates that 58% of the surface water samples fall within the extreme contamination zone, while the others are within the mixing zone; whereas 94% of groundwater samples showed evidence of mixing between groundwater and wastewater. The bacteriological assessment showed that all measured surface and groundwater samples contained Escherichia coli and total coliform bacteria. A risk map delineated four classes of contamination, namely, those sampling points with high (39.3%), moderate (36.3%), low (13.3%), and very low (11.1%) levels of contamination. Most of the highest pollution points were in the middle part of the urban area, which suffers from unmanaged sewage and industrial effluents. Overall, the results demonstrate that surface and groundwater in Qus City are at high risk of contamination by wastewater since the water table is shallow and there is a lack of a formal sanitation network infrastructure. The product risk map is a useful tool for prioritizing zones that require immediate mitigation and monitoring.

  2. Natural Contamination and Surface Flashover on Silicone Rubber Surface under Haze–Fog Environment

    Directory of Open Access Journals (Sweden)

    Ang Ren

    2017-10-01

    Full Text Available Anti-pollution flashover of insulator is important for power systems. In recent years, haze-fog weather occurs frequently, which makes discharge occurs easily on the insulator surface and accelerates insulation aging of insulator. In order to study the influence of haze-fog on the surface discharge of room temperature vulcanized silicone rubber, an artificial haze-fog lab was established. Based on four consecutive years of insulator contamination accumulation and atmospheric sampling in haze-fog environment, the contamination configuration appropriate for RTV-coated surface discharge test under simulation environment of haze-fog was put forward. ANSYS Maxwell was used to analyze the influence of room temperature vulcanized silicone rubber surface attachments on electric field distribution. The changes of droplet on the polluted room temperature vulcanized silicone rubber surface and the corresponding surface flashover voltage under alternating current (AC, direct current (DC positive polar (+, and DC negative polar (− power source were recorded by a high speed camera. The results are as follows: The main ion components from haze-fog atmospheric particles are NO3−, SO42−, NH4+, and Ca2+. In haze-fog environment, both the equivalent salt deposit density (ESDD and non-soluble deposit density (NSDD of insulators are higher than that under general environment. The amount of large particles on the AC transmission line is greater than that of the DC transmission line. The influence of DC polarity power source on the distribution of contamination particle size is not significant. After the deposition of haze-fog, the local conductivity of the room temperature vulcanized silicone rubber surface increased, which caused the flashover voltage reduce. Discharge is liable to occur at the triple junction point of droplet, air, and room temperature vulcanized silicone rubber surface. After the deformation or movement of droplets, a new triple junction

  3. SUDOQU: a new dose model to derive criteria for surface contamination of non-food (consumer) goods, containers and conveyances

    International Nuclear Information System (INIS)

    Van Dillen, Teun

    2015-01-01

    The Fukushima nuclear accident (Japan, 11 March 2011) revealed the need for well-founded criteria for surface contamination and associated screening levels related to the import of non-food (consumer) goods, containers and conveyances. The only available European-harmonised criteria are those laid down in the IAEA transport regulations, but these criteria date back from the early 1960's and only apply to the safe transport of radioactive materials. The main problem is that a generic dose-assessment model for consumer products is missing. Therefore, RIVM (National Institute for Public Health and the Environment) developed a new methodology entitled SUDOQU (Surface Dose Quantification) to calculate the annual effective dose for both consumers and non-radiological workers, addressing issues of removability of surface contamination. The methodology can be used to derive criteria and screening levels for surface contamination and could serve as a useful tool for policy-makers and radiation-protection specialists. (authors)

  4. Trench 'bathtubbing' and surface plutonium contamination at a legacy radioactive waste site.

    Science.gov (United States)

    Payne, Timothy E; Harrison, Jennifer J; Hughes, Catherine E; Johansen, Mathew P; Thiruvoth, Sangeeth; Wilsher, Kerry L; Cendón, Dioni I; Hankin, Stuart I; Rowling, Brett; Zawadzki, Atun

    2013-01-01

    Radioactive waste containing a few grams of plutonium (Pu) was disposed between 1960 and 1968 in trenches at the Little Forest Burial Ground (LFBG), near Sydney, Australia. A water sampling point installed in a former trench has enabled the radionuclide content of trench water and the response of the water level to rainfall to be studied. The trench water contains readily measurable Pu activity (~12 Bq/L of (239+240)Pu in 0.45 μm-filtered water), and there is an associated contamination of Pu in surface soils. The highest (239+240)Pu soil activity was 829 Bq/kg in a shallow sample (0-1 cm depth) near the trench sampling point. Away from the trenches, the elevated concentrations of Pu in surface soils extend for tens of meters down-slope. The broader contamination may be partly attributable to dispersion events in the first decade after disposal, after which a layer of soil was added above the trenched area. Since this time, further Pu contamination has occurred near the trench-sampler within this added layer. The water level in the trench-sampler responds quickly to rainfall and intermittently reaches the surface, hence the Pu dispersion is attributed to saturation and overflow of the trenches during extreme rainfall events, referred to as the 'bathtub' effect.

  5. Trench ‘Bathtubbing’ and Surface Plutonium Contamination at a Legacy Radioactive Waste Site

    Science.gov (United States)

    2013-01-01

    Radioactive waste containing a few grams of plutonium (Pu) was disposed between 1960 and 1968 in trenches at the Little Forest Burial Ground (LFBG), near Sydney, Australia. A water sampling point installed in a former trench has enabled the radionuclide content of trench water and the response of the water level to rainfall to be studied. The trench water contains readily measurable Pu activity (∼12 Bq/L of 239+240Pu in 0.45 μm-filtered water), and there is an associated contamination of Pu in surface soils. The highest 239+240Pu soil activity was 829 Bq/kg in a shallow sample (0–1 cm depth) near the trench sampling point. Away from the trenches, the elevated concentrations of Pu in surface soils extend for tens of meters down-slope. The broader contamination may be partly attributable to dispersion events in the first decade after disposal, after which a layer of soil was added above the trenched area. Since this time, further Pu contamination has occurred near the trench-sampler within this added layer. The water level in the trench-sampler responds quickly to rainfall and intermittently reaches the surface, hence the Pu dispersion is attributed to saturation and overflow of the trenches during extreme rainfall events, referred to as the ‘bathtub’ effect. PMID:24256473

  6. Emerging contaminants in surface waters in China—a short review

    International Nuclear Information System (INIS)

    Yang, Guang; Zhang, Guangming; Fan, Maohong

    2014-01-01

    Emerging contaminants (ECs) have drawn attention to many countries due to their persistent input and potential threat to human health and the environment. This article reviews the current contamination sources and their status for surface waters in China. The contamination levels of ECs in surface waters are in the range ng L −1 to μg L −1 in China, apparently about the same as the situation in other countries. ECs enter surface water via runoff, drainage, rainfall, and wastewater treatment effluent. The frequency of occurrence of ECs increased rapidly from 2006 to 2011; a significant reason is the production and consumption of pharmaceuticals and personal care products. As for the distribution of EC pollution in China, the frequency of occurrence of ECs in eastern regions is higher than in western regions. A majority of EC studies have focused on surface waters of the Haihe River and Pearl River watersheds due to their highly developed industries and intense human activity. Legislative and administrative regulation of ECs is lacking in China. To remove ECs, a number of technologies, such as absorption by activated carbon, membrane filtration technology, and advanced oxidation processes, have been researched. (letter)

  7. Emerging contaminants in surface waters in China—a short review

    Science.gov (United States)

    Yang, Guang; Fan, Maohong; Zhang, Guangming

    2014-07-01

    Emerging contaminants (ECs) have drawn attention to many countries due to their persistent input and potential threat to human health and the environment. This article reviews the current contamination sources and their status for surface waters in China. The contamination levels of ECs in surface waters are in the range ng L-1 to μg L-1 in China, apparently about the same as the situation in other countries. ECs enter surface water via runoff, drainage, rainfall, and wastewater treatment effluent. The frequency of occurrence of ECs increased rapidly from 2006 to 2011; a significant reason is the production and consumption of pharmaceuticals and personal care products. As for the distribution of EC pollution in China, the frequency of occurrence of ECs in eastern regions is higher than in western regions. A majority of EC studies have focused on surface waters of the Haihe River and Pearl River watersheds due to their highly developed industries and intense human activity. Legislative and administrative regulation of ECs is lacking in China. To remove ECs, a number of technologies, such as absorption by activated carbon, membrane filtration technology, and advanced oxidation processes, have been researched.

  8. Surface Chloride Levels in Colorado Structural Concrete

    Science.gov (United States)

    2018-01-01

    This project focused on the chloride-induced corrosion of reinforcing steel in structural concrete. The primary goal of this project is to analyze the surface chloride concentration level of the concrete bridge decks throughout Colorado. The study in...

  9. Wind effected redistribution of surface contamination. Progress report, September 1974--August 1975

    International Nuclear Information System (INIS)

    Amato, A.J.

    1975-01-01

    Theoretical resuspension ratios were computed through the extension of a one-dimensional model used to simulate the wind effected movement of surface contaminants. The surface movement of contamination associated with inhalable size particles was considered in relation to time, space, wind velocity, distance from the source, soil resuspension ratios, and other variables. A computer program was developed to calculate the wind effected distribution of surface contaminants. (U.S.)

  10. Monitoring of Water and Contaminant Migration at the Groundwater-Surface Water Interface

    Science.gov (United States)

    2008-08-01

    seepage is occurring in a freshwater lake environment and to map the lateral extent of any subsurface contamination at the groundwater –surface water ...and Contaminant Migration at the Groundwater -Surface Water Interface August 2008 Report Documentation Page Form ApprovedOMB No. 0704-0188 Public...4. TITLE AND SUBTITLE Monitoring of Water and Contaminant Migration at the Groundwater -Surface Water Interface 5a. CONTRACT NUMBER 5b. GRANT NUMBER

  11. Treatment options for low-level radiologically contaminated ORNL filtercake

    International Nuclear Information System (INIS)

    Lee, Hom-Ti; Bostick, W.D.

    1996-04-01

    Water softening sludge (>4000 stored low level contaminated drums; 600 drums per year) generated by the ORNL Process Waste Treatment Plant must be treated, stabilized, and placed in safe storage/disposal. The sludge is primarily CaCO 3 and is contaminated by low levels of 90 Sr and 137 Cs. In this study, microwave sintering and calcination were evaluated for treating the sludge. The microwave melting experiments showed promise: volume reductions were significant (3-5X), and the waste form was durable with glass additives (LiOH, fly ash). A commercial vendor using surrogate has demonstrated a melt mineralization process that yields a dense monolithic waste form with a volume reduction factor (VR) of 7.7. Calcination of the sludge at 850-900 C yielded a VR of 2.5. Compaction at 4500 psi increased the VR to 4.2, but the compressed form is not dimensionally stable. Addition of paraffin helped consolidate fines and yielded a VR of 3.5. In conclusion, microwave melting or another form of vitrification is likely to be the best method; however for immediate implementation, the calculation/compaction/waxing process is viable

  12. Surface Contamination Monitor and Survey Information Management System

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-02-01

    Shonka Research Associates, Inc.`s (SRA) Surface Contamination Monitor and Survey Information management System (SCM/SIMS) is designed to perform alpha and beta radiation surveys of floors and surfaces and document the measured data. The SRA-SCM/SIMS technology can be applied to routine operational surveys, characterization surveys, and free release and site closure surveys. Any large nuclear site can make use of this technology. This report describes a demonstration of the SRA-SCM/SIMS technology. This demonstration is part of the chicago Pile-5 (CP-5) Large-Scale Demonstration Project (LSDP) sponsored by the US Department of Energy (DOE), Office of Science and Technology (ST), Deactivation and Decommissioning Focus Area (DDFA). The objective of the LSDP is to select and demonstrate potentially beneficial technologies at the Argonne National Laboratory-East`s (ANL) CP-5 Research Reactor Facility. The purpose of the LSDP is to demonstrate that by using innovative and improved deactivation and decommissioning (D and D) technologies from various sources, significant benefits can be achieved when compared to baseline D and D technologies.

  13. Development of apparatus for surveying uranium surface contamination quantity

    International Nuclear Information System (INIS)

    Wang Qingheng; Han Jingquan

    1994-11-01

    An apparatus for measuring uranium contamination of the surface of reactor plate component is described. The searching unit of the apparatus is a large surface multi-wire proportional counter. The cathode of the counter is made of stainless steel with low radioactive background, the window is made of film which is plated with aluminum about 6 μm; and the anode is mad by gild tungsten wire of 0.025 mm diameter. The sensitive area of the counter is 1113 mm x 100 mm. It has been shown that the intrinsic radioactive background of the apparatus is 0.002 cpm/cm 2 (2 count/min). The detecting efficiency is 67% for enriched uranium source (2π solid angle). The stability is 0.84% within 24 hour (including detector, high voltage power supply, amplifier, discriminator, computer, type and display system). The lower detection limit of the apparatus is 4.6 x 10 -10 g/cm 2 (for 20% 235 U, 0.13% 234 U, 79.64% 238 U). The apparatus can present timing by a computer controlling, and it also has the following functions: displaying, automatic alarming, classifying and typing the results. (2 tabs., 7 figs.)

  14. Surface Contamination Monitor and Survey Information Management System

    International Nuclear Information System (INIS)

    1998-02-01

    Shonka Research Associates, Inc.'s (SRA) Surface Contamination Monitor and Survey Information management System (SCM/SIMS) is designed to perform alpha and beta radiation surveys of floors and surfaces and document the measured data. The SRA-SCM/SIMS technology can be applied to routine operational surveys, characterization surveys, and free release and site closure surveys. Any large nuclear site can make use of this technology. This report describes a demonstration of the SRA-SCM/SIMS technology. This demonstration is part of the chicago Pile-5 (CP-5) Large-Scale Demonstration Project (LSDP) sponsored by the US Department of Energy (DOE), Office of Science and Technology (ST), Deactivation and Decommissioning Focus Area (DDFA). The objective of the LSDP is to select and demonstrate potentially beneficial technologies at the Argonne National Laboratory-East's (ANL) CP-5 Research Reactor Facility. The purpose of the LSDP is to demonstrate that by using innovative and improved deactivation and decommissioning (D and D) technologies from various sources, significant benefits can be achieved when compared to baseline D and D technologies

  15. Contaminants in surface water and sediments near the Tynagh silver mine site, County Galway, Ireland

    Energy Technology Data Exchange (ETDEWEB)

    O' Neill, A. [School of Planning, Architecture and Civil Engineering, Queen' s University of Belfast, Belfast, Northern Ireland (United Kingdom); Phillips, D.H., E-mail: d.phillips@qub.ac.uk [School of Planning, Architecture and Civil Engineering, Queen' s University of Belfast, Belfast, Northern Ireland (United Kingdom); Bowen, J. [School of Planning, Architecture and Civil Engineering, Queen' s University of Belfast, Belfast, Northern Ireland (United Kingdom); Sen Gupta, B. [School of the Built Environment, Hariot-Watt University, Edinburgh, Scotland (United Kingdom)

    2015-04-15

    A former silver mine in Tynagh, Co. Galway, Ireland is one of the most contaminated mine sites in Europe with maximum concentrations of Zn, As, Pb, Mn, Ni, Cu, and Cd far exceeding guideline values for water and sediment. The aims of this research were to 1) further assess the contamination, particularly metals, in surface water and sediment around the site, and 2) determine if the contamination has increased 10 years after the Environmental Protection Agency Ireland (EPAI) identified off-site contamination. Site pH is alkaline to neutral because CaCO{sub 3}-rich sediment and rock material buffer the exposed acid generating sulphide-rich ore. When this study was compared to the previous EPAI study conducted 10 years earlier, it appeared that further weathering of exposed surface sediment had increased concentrations of As and other potentially toxic elements. Water samples from the tailings ponds and adjacent Barnacullia Stream had concentrations of Al, Cd, Mn, Zn and Pb above guideline values. Lead and Zn concentrations from the tailings pond sediment were 16 and 5 times higher, respectively, than concentrations reported 10 years earlier. Pb and Zn levels in most sediment samples exceeded the Expert Group (EGS) guidelines of 1000 and 5000 mg/kg, respectively. Arsenic concentrations were as high as 6238 mg/kg in the tailings ponds sediment, which is 62 and 862 times greater than the EGS and Canadian Soil Quality Guidelines (CSQG), respectively. Cadmium, Cu, Fe, Mn, Pb and Zn concentrations in water and sediment were above guideline values downstream of the site. Additionally, Fe, Mn and organic matter (OM) were strongly correlated and correlated to Zn, Pb, As, Cd, Cu and Ni in stream sediment. Therefore, the nearby Barnacullia Stream is also a significant pathway for contaminant transport to downstream areas. Further rehabilitation of the site may decrease the contamination around the area. - Highlights: • Tynagh silver mine in Co. Galway, Ireland is a source of

  16. Volume reduction of low-level contaminated metal waste by melting: selection of method and conceptual plan

    International Nuclear Information System (INIS)

    Copeland, G.L.; Heestand, R.L.; Mateer, R.S.

    1978-06-01

    A review of the literature and prior experience led to selection of induction melting as the most promising method for volume reduction of low-level transuranic contaminated metal waste. The literature indicates that melting with the appropriate slags significantly lowers the total contamination level of the metals by preferentially concentrating contaminants in the smaller volume of slag. Surface contamination not removed to the slag is diluted in the ingot and is contained uniformly in the metal. This dilution and decontamination offers the potential of lower cost disposal such as shallow burial rather than placement in a national repository. A processing plan is proposed as a model for economic analysis of the collection and volume reduction of contaminated metals. Further development is required to demonstrate feasibility of the plan

  17. FJ-2207 measuring instrument detection pipe surface a level of pollution method

    International Nuclear Information System (INIS)

    Wang Jiangong

    2010-01-01

    On the pipe surface contamination were detected α level of pollution is a frequently encountered dose-detection work. Because the pipeline surface arc, while the measuring probe for the plane, which for accurate measurement difficult. In this paper, on the FJ-2207-type pipe surface contamination measuring instrument measuring pollution levels in the α method was studied. Introduced the FJ-2207 measuring instrument detection pipe surface α pollution levels. Studied this measuring instrument on the same sources of surface, plane α level of radioactivity measured differences in the results obtained control of the apparatus when the direct measurement of the surface correction factor, and gives 32-216 specifications commonly used pipe direct measurement of the amendment factor. Convenient method, test results are reliable for the accurate measurement of pipe pollution levels in the surface of α as a reference and learning. (authors)

  18. Position-sensitive radiation monitoring (surface contamination monitor). Innovative technology summary report

    International Nuclear Information System (INIS)

    1999-06-01

    The Shonka Research Associates, Inc. Position-Sensitive Radiation Monitor both detects surface radiation and prepares electronic survey map/survey report of surveyed area automatically. The electronically recorded map can be downloaded to a personal computer for review and a map/report can be generated for inclusion in work packages. Switching from beta-gamma detection to alpha detection is relatively simple and entails moving a switch position to alpha and adjusting the voltage level to an alpha detection level. No field calibration is required when switching from beta-gamma to alpha detection. The system can be used for free-release surveys because it meets the federal detection level sensitivity limits requires for surface survey instrumentation. This technology is superior to traditionally-used floor contamination monitor (FCM) and hand-held survey instrumentation because it can precisely register locations of radioactivity and accurately correlate contamination levels to specific locations. Additionally, it can collect and store continuous radiological data in database format, which can be used to produce real-time imagery as well as automated graphics of survey data. Its flexible design can accommodate a variety of detectors. The cost of the innovative technology is 13% to 57% lower than traditional methods. This technology is suited for radiological surveys of flat surfaces at US Department of Energy (DOE) nuclear facility decontamination and decommissioning (D and D) sites or similar public or commercial sites

  19. Position-sensitive radiation monitoring (surface contamination monitor). Innovative technology summary report

    Energy Technology Data Exchange (ETDEWEB)

    1999-06-01

    The Shonka Research Associates, Inc. Position-Sensitive Radiation Monitor both detects surface radiation and prepares electronic survey map/survey report of surveyed area automatically. The electronically recorded map can be downloaded to a personal computer for review and a map/report can be generated for inclusion in work packages. Switching from beta-gamma detection to alpha detection is relatively simple and entails moving a switch position to alpha and adjusting the voltage level to an alpha detection level. No field calibration is required when switching from beta-gamma to alpha detection. The system can be used for free-release surveys because it meets the federal detection level sensitivity limits requires for surface survey instrumentation. This technology is superior to traditionally-used floor contamination monitor (FCM) and hand-held survey instrumentation because it can precisely register locations of radioactivity and accurately correlate contamination levels to specific locations. Additionally, it can collect and store continuous radiological data in database format, which can be used to produce real-time imagery as well as automated graphics of survey data. Its flexible design can accommodate a variety of detectors. The cost of the innovative technology is 13% to 57% lower than traditional methods. This technology is suited for radiological surveys of flat surfaces at US Department of Energy (DOE) nuclear facility decontamination and decommissioning (D and D) sites or similar public or commercial sites.

  20. Monitoring of raptors and their contamination levels in Norway.

    Science.gov (United States)

    Gjershaug, Jan Ove; Kålås, John Atle; Nygård, Torgeir; Herzke, Dorte; Folkestad, Alv Ottar

    2008-09-01

    This article summarizes results from raptor monitoring and contamination studies in Norway of the golden eagle, gyrfalcon, white-tailed sea eagle, osprey, peregrine, and merlin. Golden eagle and gyrfalcon populations have been monitored since 1990 as part of the "Monitoring Programme for Terrestrial Ecosystems" (TOV). No long-term trend in the population size or productivity of golden eagle has been shown in any of the 5 study areas. The reproductive output of gyrfalcon is monitored in 3 areas. It is positively correlated with the populations of its main prey species, the rock ptarmigan and the willow ptarmigan. The white-tailed sea eagle population has been monitored since 1974 by the Norwegian Ornithological Society, and the population is increasing. The levels of pesticides and polychlorinated biphenyls are low in the eggs of both the golden eagle and the gyrfalcon, but elevated levels and effects on reproduction have been indicated for a coastal subpopulation of golden eagle. The pollutant levels in white-tailed sea eagle are lower than in the Baltic population of sea eagles, and shell thinning was never severe overall, but individual eggs have contained pollutant concentrations above critical levels. The levels of pollutants in the bird-eating falcons, peregrine, and merlin were higher than in other species. New emerging pollutants, like brominated diphenylethers and perfluorinated organic compounds, could be detected in all species. By incorporating available published and unpublished data, we were able to produce time trends for pollutants and shell thickness over 4 decades.

  1. Limits determination of microbial contamination present on surfaces from a pharmaceutical microbiology district reference laboratory

    Directory of Open Access Journals (Sweden)

    Natalia Charry

    2016-06-01

    Full Text Available Context: The bioburden present on the pharmaceutical microbiology laboratory’s surfaces, may increase the risk of cross-contamination when analytical tests are being carried out; periodic monitoring allows to set limits that reduce the risk. Aims: To determinate the limits of bioburden present on seven surfaces of the pharmaceutical microbiology laboratory, after the cleaning and disinfection process. Methods: The swabbing method was used for sampling. With a 25 cm2 stencil and a sterile swab, a sample was taken, passing the swab over five points of every surface chosen. A total aerobic microbial count and a total yeast and mold count was done. Finally, the average and the standard deviation of the counts was obtained. Results: The average from the counts obtained on each surface selected for the study, were below the recommended limits by international entities like the World Health Organization and the European Union, between others; also, the results generated in this study, allow to classify the biosafety cabinet as an ISO 5 area and the other areas as ISO 7. Conclusions: Bioburden levels on the tested surfaces are considered low, reducing the risk of cross-contamination, which could have a negative impact on laboratory’s activities. Also, it follows that disinfectant concentration used, is effectively.

  2. Bioremediation of contaminated surface water by immobilized Micrococcus roseus.

    Science.gov (United States)

    Li, H; Li, P; Hua, T; Zhang, Y; Xiong, X; Gong, Z

    2005-08-01

    The problems caused by contaminated surface water have gradually become more serious in recent years. Although various remediation technologies were investigated, unfortunately, no efficient method was developed. In this paper, a new bioremediation technology was studied using Micrococcus roseus, which was immobilized in porous spherical beads by an improved polyvinyl alcohol (PVA) - sodium alginate (SA) embedding method. The experimental results indicated that COD removal rate could reach 64.7 % within 72 hours when immobilized M. roseus beads were used, which was ten times as high as that of free cells. The optimum inoculation rate of immobilized M. roseus beads was 10 % (mass percent of the beads in water sample, g g(-1)). Suitable aeration was proved necessary to enhance the bioremediation process. The immobilized cells had an excellent tolerance to pH and temperature changes, and were also more resistant to heavy metal stress compared with free cells. The immobilized M. roseus beads had an excellent regeneration capacity and could be reused after 180-day continuous usage. The Scanning Electronic Microscope (SEM) analysis showed that the bead microstructure was suitable for M. roseus growth, however, some defect structures should still be improved.

  3. A simplified ALARA approach to demonstration of compliance with surface contaminated object regulatory requirements

    International Nuclear Information System (INIS)

    Pope, R.B.; Shappert, L.B.; Michelhaugh, R.D.; Boyle, R.W.; Cook, J.C.

    1998-02-01

    The US Department of Transportation (DOT) and the US Nuclear Regulatory Commission (NRC) have jointly prepared a comprehensive set of draft guidance for consignors and inspectors to use when applying the newly imposed regulatory requirements for low specific activity (LSA) material and surface contaminated objects (SCOs). The guidance is being developed to facilitate compliance with the new LSA material and SCO requirements, not to impose additional requirements. These new requirements represent, in some areas, significant departures from the manner in which packaging and transportation of these materials and objects were previously controlled. On occasion, it may be appropriate to use conservative approaches to demonstrate compliance with some of the requirements, ensuring that personnel are not exposed to radiation at unnecessary levels, so that exposures are kept as low as reasonably achievable (ALARA). In the draft guidance, one such approach would assist consignors preparing a shipment of a large number of SCOs in demonstrating compliance without unnecessarily exposing personnel. In applying this approach, users need to demonstrate that four conditions are met. These four conditions are used to categorize non-activated, contaminated objects as SCO-2. It is expected that, by applying this approach, it will be possible to categorize a large number of small contaminated objects as SCO-2 without the need for detailed, quantitative measurements of fixed, accessible contamination, or of total (fixed and non-fixed) contamination on inaccessible surfaces. The method, which is based upon reasoned argument coupled with limited measurements and the application of a sum of fractions rule, is described and examples of its use are provided

  4. Accuracy Analysis of a Robotic Radionuclide Inspection and Mapping System for Surface Contamination

    International Nuclear Information System (INIS)

    Mauer, Georg F.; Kawa, Chris

    2008-01-01

    The mapping of localized regions of radionuclide contamination in a building can be a time consuming and costly task. Humans moving hand-held radiation detectors over the target areas are subject to fatigue. A contamination map based on manual surveys can contain significant operator-induced inaccuracies. A Fanuc M16i light industrial robot has been configured for installation on a mobile aerial work platform, such as a tall forklift. When positioned in front of a wall or floor surface, the robot can map the radiation levels over a surface area of up to 3 m by 3 m. The robot's end effector is a commercial alpha-beta radiation sensor, augmented with range and collision avoidance sensors to ensure operational safety as well as to maintain a constant gap between surface and radiation sensors. The accuracy and repeatability of the robotically conducted contamination surveys is directly influenced by the sensors and other hardware employed. This paper presents an in-depth analysis of various non-contact sensors for gap measurement, and the means to compensate for predicted systematic errors that arise during the area survey scans. The range sensor should maintain a constant gap between the radiation counter and the surface being inspected. The inspection robot scans the wall surface horizontally, moving down at predefined vertical intervals after each scan in a meandering pattern. A number of non-contact range sensors can be employed for the measurement of the gap between the robot end effector and the wall. The nominal gap width was specified as 10 mm, with variations during a single scan not to exceed ± 2 mm. Unfinished masonry or concrete walls typically exhibit irregularities, such as holes, gaps, or indentations in mortar joints. These irregularities can be sufficiently large to indicate a change of the wall contour. The responses of different sensor types to the wall irregularities vary, depending on their underlying principles of operation. We explored

  5. An Immunoassay for Quantification of Contamination by Raw Meat Juice on Food Contact Surfaces.

    Science.gov (United States)

    Chen, Fur-Chi; Godwin, Sandria; Chambers, Edgar

    2016-11-01

    Raw chicken products often are contaminated with Salmonella and Campylobacter , which can be transmitted from packages to contact surfaces. Raw meat juices from these packages also provide potential media for cross-contamination. There are limited quantitative data on the levels of consumer exposure to raw meat juice during shopping for and handling of chicken products. An exposure assessment is needed to quantify the levels of transmission and to assess the risk. An enzyme-linked immunosorbent assay (ELISA) was developed and validated for quantitative detection of raw meat juice on hands and various food contact surfaces. Analytical procedures were designed to maximize the recovery of raw meat juice from various surfaces: hands, plastic, wood, stainless steel, laminated countertops, glass, and ceramics. The ELISA was based on the detection of a soluble muscle protein, troponin I (TnI), in the raw meat juice. The assay can detect levels as low as 1.25 ng of TnI, which is equivalent to less than 1 μl of the raw meat juice. The concentrations of TnI in the raw meat juices from 10 retail chicken packages, as determined by ELISA, were between 0.46 and 3.56 ng/μl, with an average of 1.69 ng/μl. The analytical procedures, which include swabbing, extraction, and concentration, enable the detection of TnI from various surfaces. The recoveries of raw meat juice from surfaces of hands were 92%, and recoveries from other tested surfaces were from 55% on plastic cutting boards to 75% on laminated countertops. The ELISA developed has been used for monitoring the transfer of raw meat juice during shopping for and handling of raw chicken products in our studies. The assay also can be applied to other raw meat products, such as pork and beef.

  6. Microbial contamination level profiles attributed to contamination of beef carcasses, personnel, and equipment: case of small and medium enterprise slaughterhouses

    DEFF Research Database (Denmark)

    Wambui, Joseph; Lamuka, Peter; Karuri, Edward

    2018-01-01

    The microbial contamination level profiles (MCLPs) attributed to contamination of beef carcasses, personnel, and equipment in five Kenyan small and medium enterprise slaughterhouses were determined. Aerobic plate counts, Enterobacteriaceae, Staphylococcus, and Salmonella were used to determine...... contamination at four different slaughter stages, namely, dehiding, evisceration, splitting, and dispatch. Microbiological criteria of the four microorganisms were used to score contamination levels (CLs) as poor (0), poor to average (1), average (2), or good (3). MCLPs were further assigned to carcasses......, personnel, and equipment at each stage by summing up the CL scores. The CL score attributed to aerobic plate count contamination was 2 or 3 for carcasses but 0 for personnel and equipment in almost all slaughterhouses. A score of 0 on carcasses was mostly attributed to Enterobacteriaceae at evisceration...

  7. The organic contamination level based on the total soil mass is not a proper index of the soil contamination intensity

    Science.gov (United States)

    Hung, H.-W.; Daniel, Sheng G.; Lin, T.-F.; Su, Y.; Chiou, C.T.

    2009-01-01

    Concentrations of organic contaminants in common productive soils based on the total soil mass give a misleading account of actual contamination effects. This is attributed to the fact that productive soils are essentially water-saturated, with the result that the soil uptake of organic compounds occurs principally by partition into the soil organic matter (SOM). This report illustrates that the soil contamination intensity of a compound is governed by the concentration in the SOM (Com) rather than by the concentration in whole soil (Cs). Supporting data consist of the measured levels and toxicities of many pesticides in soils of widely differing SOM contents and the related levels in in-situ crops that defy explanation by the Cs values. This SOM-based index is timely needed for evaluating the contamination effects of food crops grown in different soils and for establishing a dependable priority ranking for intended remediation of numerous contamination sites.

  8. Assessment of Surface Water Contamination from Coalbed Methane Fracturing-Derived Volatile Contaminants in Sullivan County, Indiana, USA.

    Science.gov (United States)

    Meszaros, Nicholas; Subedi, Bikram; Stamets, Tristan; Shifa, Naima

    2017-09-01

    There is a growing concern over the contamination of surface water and the associated environmental and public health consequences from the recent proliferation of hydraulic fracturing in the USA. Petroleum hydrocarbon-derived contaminants of concern [benzene, toluene, ethylbenzene, and xylenes (BTEX)] and various dissolved cations and anions were spatially determined in surface waters around 15 coalbed methane fracking wells in Sullivan County, IN, USA. At least one BTEX compound was detected in 69% of sampling sites (n = 13) and 23% of sampling sites were found to be contaminated with all of the BTEX compounds. Toluene was the most common BTEX compound detected across all sampling sites, both upstream and downstream from coalbed methane fracking wells. The average concentration of toluene at a reservoir and its outlet nearby the fracking wells was ~2× higher than other downstream sites. However, one of the upstream sites was found to be contaminated with BTEX at similar concentrations as in a reservoir site nearby the fracking well. Calcium (~60 ppm) and sulfates (~175 ppm) were the dominant cations and anions, respectively, in surface water around the fracking sites. This study represents the first report of BTEX contamination in surface water from coalbed methane hydraulic fracturing wells.

  9. Contamination Revealed by Indicator Microorganism Levels during Veal Processing.

    Science.gov (United States)

    Bosilevac, Joseph M; Wang, Rong; Luedtke, Brandon E; Wheeler, Tommy L; Koohmaraie, Mohammad

    2016-08-01

    During site visits of veal processors, the U.S. Department of Agriculture, Food Safety Inspection Service (FSIS) has reported processing deficiencies that likely contribute to increased levels of veal contamination. Here, we report the results of measuring aerobic plate count bacteria (APC), Enterobacteriaceae, coliforms (CF), and Escherichia coli during eight sample collections at five veal processors to assess contamination during the harvest of bob veal and formula-fed veal before (n = 5 plants) and after (n = 3 plants) changes to interventions and processing practices. Hides of veal calves at each plant had mean log CFU/100 cm(2) APC, Enterobacteriaceae, CF, and E. coli of 6.02 to 8.07, 2.95 to 5.24, 3.28 to 5.83, and 3.08 to 5.59, respectively. Preintervention carcasses had mean log CFU/100 cm(2) APC, Enterobacteriaceae, CF, and E. coli of 3.08 to 5.22, 1.16 to 3.47, 0.21 to 3.06, and -0.07 to 3.10, respectively, before and 2.72 to 4.50, 0.99 to 2.76, 0.69 to 2.26, and 0.33 to 2.12, respectively, after changes were made to improve sanitary dressing procedures. Final veal carcasses had mean log CFU/100 cm(2) APC, Enterobacteriaceae, CF, and E. coli of 0.36 to 2.84, -0.21 to 1.59, -0.23 to 1.59, and -0.38 to 1.45 before and 0.44 to 2.64, -0.16 to 1.33, -0.42 to 1.20, and 0.48 to 1.09 after changes were made to improve carcass-directed interventions. Whereas the improved dressing procedures resulted in improved carcass cleanliness, the changes to carcass-directed interventions were less successful, and veal processors are urged to use techniques that ensure uniform and consistent delivery of antimicrobials to carcasses. Analysis of results comparing bob veal to formula-fed veal found bob veal hides, preintervention carcasses, and final carcasses to have increased (P 0.05) relative to formula fed veal. When both veal categories were harvested at the same plant on the same day, similar results were observed. Since identification by FSIS, the control of

  10. A Review of Removable Surface Contamination on Radioactive Materials Transportation Containers

    Energy Technology Data Exchange (ETDEWEB)

    Kennedy, Jr, W. E.; Watson, E. C.; Murphy, D. W.; Harrer, B. J.; Harty, R.; Aldrich, J. M.

    1981-05-01

    This report contains the results of a study sponsored by the U.S. Nuclear Regulatory Commission (NRC) of removable surface contamination on radioactive materials transportation containers. The purpose of the study is to provide information to the NRC during their review of existing regulations. Data was obtained from both industry and literature on three major topics: 1) radiation doses, 2) economic costs, and 3) contamination frequencies. Containers for four categories of radioactive materials are considered including radiopharmaceuticals, industrial sources, nuclear fuel cycle materials, and low-level radioactive waste. Assumptions made in this study use current information to obtain realistic yet conservative estimates of radiation dose and economic costs. Collective and individual radiation doses are presented for each container category on a per container basis. Total doses, to workers and the public, are also presented for spent fuel cask and low-level waste drum decontamination. Estimates of the additional economic costs incurred by lowering current limits by factors of 10 and 100 are presented. Current contamination levels for each category of container are estimated from the data collected. The information contained in this report is designed to be useful to the NRC in preparing their recommendations for new regulations.

  11. 10 CFR Appendix D to Part 835 - Surface Contamination Values

    Science.gov (United States)

    2010-01-01

    ... posting of contamination and high contamination areas in accordance with § 835.603(e) and (f) and...-228, Th-230, Th-228, Pa-231, Ac-227, I-125, I-129 20 500 Th-nat, Th-232, Sr-90, Ra-223, Ra-224, U-232... pressure, and then assessing the amount of radioactive material on the swipe with an appropriate instrument...

  12. Level of Campylobacter jejuni from naturally contaminated chicken liver and chicken legs in various task: a cross contamination study

    Directory of Open Access Journals (Sweden)

    New, C.Y.

    2017-03-01

    Full Text Available Cross contamination is one of the most important contributing factors in foodborne illness originating in household environments. The objective of this research was to determine the transfer between naturally contaminated chicken liver and leg to cutting board, hand glove, knife and cucumber, during slicing. The microorganism tested was Campylobacter jejuni and the results showed that the pathogen transferred to all utensils, at different transfer rate, despite the low level of the naturally contaminating pathogen. With unknown concentration bacteria in the naturally contaminated samples, a proportion of the utensils were still contaminated with C. jejuni and not surprisingly, when the sample were contaminated with higher concentrations of the pathogen, a higher proportion of the utensils had detectable C. jejuni cells present, though in many cases cross contamination seems to be a random event. Transfer of the naturally contaminating C. jejuni from the chicken liver and leg to the utensils were <3.0 to 9.2 MPN/g and <3.0 to 3.0 MPN/g, respectively. The results of this study highlighted the potential for cross contamination of food borne pathogens in the kitchen environment.

  13. A risk-informed basis for establishing non-fixed surface contamination limits for spent fuel transportation casks

    International Nuclear Information System (INIS)

    Rawl, R.R.; Eckerman, K.F.; Bogard, J.S.; Cook, J.R.

    2004-01-01

    The current limits for non-fixed contamination on packages used to transport radioactive materials were introduced in the 1961 edition of the International Atomic Energy Agency (IAEA) transport regulations and were based on radiation protection guidance and practices in use at that time. The limits were based on exposure scenarios leading to intakes of radionuclides by inhalation and external irradiation of the hands. These considerations are collectively referred to as the Fairbairn model. Although formulated over 40 years ago, the model remains unchanged and is still the basis of current regulatory-derived limits on package non-fixed surface contamination. There can also be doses that while not resulting directly from the contamination, are strongly influenced by and attributable to transport regulatory requirements for contamination control. For example, actions necessary to comply with the current derived limits for light-water-reactor (LWR) spent nuclear fuel (SNF) casks can result in significant external doses to workers. This is due to the relatively high radiation levels around the loaded casks, where workers must function during the measurement of contamination levels and while decontaminating the cask. In order to optimize the total dose received due to compliance with cask contamination levels, it is necessary to take into account all the doses that vary as a result of the regulatory limit. Limits for non-fixed surface contamination on spent fuel casks should be established by using a model that considers and optimizes the appropriate exposure scenarios both in the workplace and in the public environment. A risk-informed approach is needed to ensure optimal use of personnel and material resources for SNF-based packaging operations. This paper is a summary of a study sponsored by the US Nuclear Regulatory Commission and performed by Oak Ridge National Laboratory that examined the dose implications for removable surface contamination limits on spent fuel

  14. Morphology and Differentiation of MG63 Osteoblast Cells on Saliva Contaminated Implant Surfaces

    Directory of Open Access Journals (Sweden)

    Neda Shams

    2015-11-01

    Full Text Available Objectives: Osteoblasts are the most important cells in the osseointegration process. Despite years of study on dental Implants, limited studies have discussed the effect of saliva on the adhesion process of osteoblasts to implant surfaces. The aim of this in vitro study was to evaluate the effect of saliva on morphology and differentiation of osteoblasts attached to implant surfaces.Materials and Methods: Twelve Axiom dental implants were divided into two groups. Implants of the case group were placed in containers, containing saliva, for 40 minutes. Then, all the implants were separately stored in a medium containing MG63 human osteoblasts for a week. Cell morphology and differentiation were assessed using a scanning electron microscope and their alkaline phosphatase (ALP activity was determined. The t-test was used to compare the two groups.Results: Scanning electron microscopic observation of osteoblasts revealed round or square cells with fewer and shorter cellular processes in saliva contaminated samples, whereas elongated, fusiform and well-defined cell processes were seen in the control group. ALP level was significantly lower in case compared to control group (P<0.05.Conclusion: Saliva contamination alters osteoblast morphology and differentiation and may subsequently interfere with successful osseointegration. Thus, saliva contamination of bone and implant must be prevented or minimized.

  15. Multicenter evaluation of a new closed system drug-transfer device in reducing surface contamination by antineoplastic hazardous drugs.

    Science.gov (United States)

    Bartel, Sylvia B; Tyler, Timothy G; Power, Luci A

    2018-02-15

    Results of a study to evaluate the effectiveness of a recently introduced closed system drug-transfer device (CSTD) in reducing surface contamination during compounding and simulated administration of antineoplastic hazardous drugs (AHDs) are reported. Wipe samples were collected from 6 predetermined surfaces in compounding and infusion areas of 13 U.S. cancer centers to establish preexisting levels of surface contamination by 2 marker AHDs (cyclophosphamide and fluorouracil). Stainless steel templates were placed over the 6 previously sampled surfaces, and the marker drugs were compounded and infused per a specific protocol using all components of the CSTD. Wipe samples were collected from the templates after completion of tasks and analyzed for both marker AHDs. Aggregated results of wipe sampling to detect preexisting contamination at the 13 study sites showed that overall, 66.7% of samples (104 of 156) had detectable levels of at least 1 marker AHD; subsequent testing after CSTD use per protocol found a sample contamination rate of 5.8% (9 of 156 samples). In the administration areas alone, the rate of preexisting contamination was 78% (61 of 78 samples); with use of the CSTD protocol, the contamination rate was 2.6%. Twenty-six participants rated the CSTD for ease of use, with 100% indicating that they were satisfied or extremely satisfied. A study involving a rigorous protocol and 13 cancer centers across the United States demonstrated that the CSTD reduced surface contamination by cyclophosphamide and fluorouracil during compounding and simulated administration. Participants reported that the CSTD was easy to use. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  16. Level crossing analysis of growing surfaces

    International Nuclear Information System (INIS)

    Shahbazi, F; Sobhanian, S; Tabar, M Reza Rahimi; Khorram, S; Frootan, G R; Zahed, H

    2003-01-01

    We investigate the average frequency of positive slope ν + α , crossing the height α = h - h-bar in the surface growing processes. The exact level crossing analysis of the random deposition model and the Kardar-Parisi-Zhang equation in the strong coupling limit before creation of singularities is given

  17. The accuracy of surface-contamination measurements; survey of UK hospitals, 1986

    International Nuclear Information System (INIS)

    Woods, M.J.

    1987-01-01

    In response to a number of concerns expressed at both national and international levels, the National Physical Laboratory (NPL) conducted a survey of UK hospitals and associated Regional Radiation Protection Services. Sources of surface contamination were distributed and participants were requested to measure these and interpret the relevant responses in terms of emission and activity per unit area. The analysis of the returns demonstrates that the vast majority of results was significantly in error and that the quality of radiation protection may be impaired. (author)

  18. Atmospheric pressure plasma cleaning of contamination surfaces. 1997 mid-year progress report

    International Nuclear Information System (INIS)

    Hicks, R.; Selwyn, G.S.

    1997-01-01

    'Goals of the project are to (1) identify the key physics and chemistry underlying the use of high pressure plasmas for etching removal of actinides and actinide surrogates; and (2) identify key surface reactions and plasma physics necessary for optimization of the atmospheric pressure plasma jet. Technical description of the work decommissioning of transuranic waste (TRU) into low-level radioactive waste (LLW) represents the largest cleanup cost associated with the nuclear weapons complex. This work is directed towards developing a low-cost plasma technology capable of converting TRU into LLW, based upon highly selective plasma etching of plutonium and other actinides from contaminated surfaces. In this way, only the actinide material is removed, leaving the surface less contaminated. The plasma etches actinide material by producing a volatile halide compound, which may be efficiently trapped using filters. To achieve practical, low-cost operation of a plasma capable of etching actinide materials, the authors have developed a y-mode, resonant-cavity, atmospheric pressure plasma jet (APPJ). In contrast to conventional, low pressure plasmas, the APPJ produces a purely-chemical effluent free of ions, and so achieves very high selectivity and produces negligible damage to the surface. Since the jet operates outside a chamber, many nuclear wastes may be treated including machinery, duct-work, concrete and other building materials. In some cases, it may be necessary to first remove paint from contaminated surfaces using a plasma selective for that surface, then to switch to the actinide etching chemistry for removal of actinide contamination. The goal of this work is to develop the underlying science required for maturation of this technology and to establish early version engineering prototypes. Accomplishments to Date The authors have made significant progress in this program. The work conducted jointly at Los Alamos and at UCLA. This has been facilitated by exchange

  19. Atmospheric pressure plasma cleaning of contamination surfaces. 1997 mid-year progress report

    Energy Technology Data Exchange (ETDEWEB)

    Selwyn, G.S. [Los Alamos National Lab., NM (US); Hicks, R. [Univ. of California, Los Angeles, CA (US)

    1997-06-01

    'Goals of the project are to (1) identify the key physics and chemistry underlying the use of high pressure plasmas for etching removal of actinides and actinide surrogates; and (2) identify key surface reactions and plasma physics necessary for optimization of the atmospheric pressure plasma jet. Technical description of the work decommissioning of transuranic waste (TRU) into low-level radioactive waste (LLW) represents the largest cleanup cost associated with the nuclear weapons complex. This work is directed towards developing a low-cost plasma technology capable of converting TRU into LLW, based upon highly selective plasma etching of plutonium and other actinides from contaminated surfaces. In this way, only the actinide material is removed, leaving the surface less contaminated. The plasma etches actinide material by producing a volatile halide compound, which may be efficiently trapped using filters. To achieve practical, low-cost operation of a plasma capable of etching actinide materials, the authors have developed a y-mode, resonant-cavity, atmospheric pressure plasma jet (APPJ). In contrast to conventional, low pressure plasmas, the APPJ produces a purely-chemical effluent free of ions, and so achieves very high selectivity and produces negligible damage to the surface. Since the jet operates outside a chamber, many nuclear wastes may be treated including machinery, duct-work, concrete and other building materials. In some cases, it may be necessary to first remove paint from contaminated surfaces using a plasma selective for that surface, then to switch to the actinide etching chemistry for removal of actinide contamination. The goal of this work is to develop the underlying science required for maturation of this technology and to establish early version engineering prototypes. Accomplishments to Date The authors have made significant progress in this program. The work conducted jointly at Los Alamos and at UCLA. This has been facilitated by

  20. Radioactive contamination of some rubber or plastic surfaces by fission products. Decontamination tests

    International Nuclear Information System (INIS)

    Mestre, E.; Sautiez, N.

    1957-10-01

    With the objective of notably addressing the contamination and decontamination of gloves and floor covering, this report first presents some characteristics of contaminating radioactive materials (nature, physical and chemical condition), of contaminated surfaces (surface condition, surface nature), and of decontamination processes (physical, chemical or mechanical action). It describes the operational modality implemented to test decontamination processes on various glove or flooring materials: sample preparation, counting, decontamination, reproducibility of decontamination tests, results in terms of activity reduction. It more precisely describes the tested samples: short gloves, gloves from glove boxes, floor and wall coverings. Results are presented and discussed in terms of sample susceptibility to contamination, and of decontamination, but also for re-contamination tests after a Nab-based decontamination (susceptibility to contamination, decontamination gain)

  1. Ion implanters contamination on wafer surface analyzed by ToF-SIMS and SPV analytical techniques

    International Nuclear Information System (INIS)

    Ricciari, R.; Bertini, M.; Ferlito, E.P.; Pizzo, G.; Anastasi, G.; Mello, D.; Franco, G.

    2007-01-01

    In ULSI processes, metallic contamination controls are very important issues. For the ion implantation process it is known that several sources of contaminations still need to be controlled: metals from sputtering of the apertures or wafer holders, Na + contaminations from filament impurities and messy maintenance procedure. ToF-SIMS is one of the most promising candidates to perform in-line surface analysis due to its high sensitivity. It is very common to use surface photo-voltage (SPV) techniques to control ion implanter equipments but this kind of analysis is an indirect measure for metallic contamination. The aim of this work is to study the possibility to use ToF-SIMS instead of SPV for in line equipment contamination monitoring. For this reason a comparison between SPV and ToF-SIMS data occurred. Good correlation between the data is shown; moreover ToF-SIMS spectra give detailed information about the other contaminations present on the wafer surface

  2. Energy level alignment and molecular conformation at rubrene/Ag interfaces: Impact of contact contaminations on the interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, Sumona, E-mail: sumona.net.09@gmail.com [Saha Institute of Nuclear Physics, 1/AF, Bidhannagar, Kolkata 700064 (India); Wang, C.-H. [National Synchrotron Radiation Research Center, Hsinchu 30076, Taiwan (China); Mukherjee, M. [Saha Institute of Nuclear Physics, 1/AF, Bidhannagar, Kolkata 700064 (India)

    2017-07-01

    Highlights: • Impact of contact contaminations on the energy level alignment and molecular conformation at rubrene/Ag interfaces. • Adventitious contamination layer was acted as a spacer layer between Ag substrate surface and rubrene molecular layer. • Hole injection barrier height and interface dipole at rubrene/Ag interfaces depend on the cleanliness of Ag substrate. • Molecular conformation as well as orientation controlled by the cleanliness of Ag surface. • Resulted different surface morphology of rubrene thin films on unclean and clean Ag substrate. - Abstract: This paper addresses the impact of electrode contaminations on the interfacial energy level alignment, the molecular conformation, orientation and surface morphology deposited organic film at organic semiconductor/noble metal interfaces by varying of film thickness from sub-monolayer to multilayer, which currently draws significant attention with regard to its application in organic electronics. The UHV clean Ag and unclean Ag were employed as substrate whereas rubrene was used as an organic semiconducting material. The photoelectron spectroscopy (XPS and UPS) was engaged to investigate the evolution of interfacial energetics; polarization dependent near edge x-ray absorption fine structure spectroscopy (NEXAFS) was employed to understand the molecular conformation as well as orientation whereas atomic force microscopy (AFM) was used to investigate the surface morphologies of the films. The adventitious contamination layer was acted as a spacer layer between clean Ag substrate surface and rubrene molecular layer. As a consequence, hole injection barrier height, interface dipole as well as molecular-conformation, molecular-orientation and surface morphology of rubrene thin films were found to depend on the cleanliness of Ag substrate. The results have important inferences about the understanding of the impact of substrate contamination on the energy level alignment, the molecular conformation

  3. Environmental contamination from a ground-level release of fission products

    International Nuclear Information System (INIS)

    Stupka, R.C.; Kephart, G.S.; Rittmann, P.D.

    1986-08-01

    On January 11, 1985, a ground-level release of fission products, primarily 90 Sr, occurred at the Hanford Site in southeastern Washington State. The release was detected during routine surveys and the majority of the contamination was confined to the immediate area where the release occurred. Response to the incident was complicated by a strong inversion that resulted in a buildup of 222 Rn daughter products on environmental air samples and outdoor surfaces. The cause of the release appears to have been the operation of a transfer jet that inadvertently pressurized an unblanked line leading to the 241-C-151 Diversion Box. A buildup of pressure inside the diversion box forced contaminated air through gaps in the diversion box cover blocks resulting in an unmonitored, short duration release to the environment. The source term was estimated using data obtained from environmental air samplers. The ground deposition speed was calculated using the integrated exposure (air samples) and surface contamination levels obtained from recently fallen snow. The total release was estimated to be 1.4 Ci 90 Sr and 0.02 Ci 137 Cs. Based on this source term, the maximum 50-yr dose commitment to onsite pesonnel was 50 mrem whole body and 600 mrem bone. No detectable internal deposition occurred during the incident and corrective action which followed; this was probably due to several factors: (1) prompt detection of the release; (2) localized contamination control; (3) excellent personnel protection practices; and (4) the protection offered by building ventilation systems. The theoretical maximum offsite individual would receive a potential 1-yr dose commitment of 0.01 mrem whole body and 0.2 mrem bone from this incident. The potential 50-yr dose commitment would be 0.13 mrem whole body and 2.0 mrem bone. In actuality, neither onsite or offsite individuals would be expected to receive even these small dose commitments

  4. Surface-to-surface registration using level sets

    DEFF Research Database (Denmark)

    Hansen, Mads Fogtmann; Erbou, Søren G.; Vester-Christensen, Martin

    2007-01-01

    This paper presents a general approach for surface-to-surface registration (S2SR) with the Euclidean metric using signed distance maps. In addition, the method is symmetric such that the registration of a shape A to a shape B is identical to the registration of the shape B to the shape A. The S2SR...... problem can be approximated by the image registration (IR) problem of the signed distance maps (SDMs) of the surfaces confined to some narrow band. By shrinking the narrow bands around the zero level sets the solution to the IR problem converges towards the S2SR problem. It is our hypothesis...... that this approach is more robust and less prone to fall into local minima than ordinary surface-to-surface registration. The IR problem is solved using the inverse compositional algorithm. In this paper, a set of 40 pelvic bones of Duroc pigs are registered to each other w.r.t. the Euclidean transformation...

  5. Lead contamination and transfer in urban environmental compartments analyzed by lead levels and isotopic compositions

    International Nuclear Information System (INIS)

    Hu, Xin; Sun, Yuanyuan; Ding, Zhuhong; Zhang, Yun; Wu, Jichun; Lian, Hongzhen; Wang, Tijian

    2014-01-01

    Lead levels and isotopic compositions in atmospheric particles (TSP and PM 2.5 ), street dust and surface soil collected from Nanjing, a mega city in China, were analyzed to investigate the contamination and the transfer of lead in urban environmental compartments. The lead contents in TSP and PM 2.5 are significantly higher than them in the surface soil and street dust (p  206 Pb/ 207 Pb vs. 208 Pb/ 206 Pb and 206 Pb/ 207 Pb vs. 1/Pb imply that the street dust and atmospheric particles (TSP and PM 2.5 ) have very similar lead sources. Coal emissions and smelting activities may be the important lead sources for street dust and atmospheric particles (TSP and PM 2.5 ), while the deposition of airborne lead is an important lead source for urban surface soil. - Highlights: • Lead levels and isotope ratios in atmospheric particles, street dust and surface soil. • Significant enrichment of lead in atmospheric particles was observed. • Street dust and atmospheric particles have similar lead sources. • Endmembers of soil lead differ from street dust and atmospheric particles. • Airborne lead poses the main risks to unban environmental quality. - Transfer of airborne particle bound lead into street dust and surface soil in unban environmental based on lead levels and isotopic compositions

  6. Is metal contamination responsible for increasing aneuploidy levels in the Manila clam Ruditapes philippinarum?

    KAUST Repository

    Piló, D.

    2016-11-03

    The present study assessed the metal genotoxicity potential at chromosome-level in the bivalve Ruditapes philippinarum collected along different areas of the Tagus estuary. Higher levels of aneuploidy on gill cells were detected at the most sediment contaminated area both in May (31.7%) and October (36.0%) when compared to a less contaminated area over the same periods (20.3% and 29.0% respectively). Interestingly, metal bioaccumulation in gills was higher in the specimens collected at the least contaminated area with the exception of Pb. Indeed, the multivariate analysis revealed a stronger relation between aneuploidy and sediment contamination than between aneuploidy and the bioaccumulation of the metals. The temporal and spatial inconsistency found for the bioaccumulation of metals in R. philippinarum and the positive correlation between sediment contamination and aneuploidy at the most contaminated area suggest that these chromosome-level effects might be due to chronic metal contamination occurring in the Tagus estuary, rather than a direct result of the temporal variation of bioavailable contaminants. The vertical transmission phenomenon of bivalve aneuploidy levels may then be perpetuating those levels on clams from the most contaminated area. The present results shed light about the effect of metal toxicity at the chromosome-level in species inhabiting chronic contaminated areas and highlight the use of aneuploidy as an effective tool to identify persistent contamination in worldwide transitional waters.

  7. Fate factors and emission flux estimates for emerging contaminants in surface waters

    Directory of Open Access Journals (Sweden)

    Hoa T. Trinh

    2016-01-01

    Full Text Available Pharmaceuticals, personal care products, hormones, and wastewater products are emerging environmental concerns for manifold reasons, including the potential of some compounds found in these products for endocrine disruption at a very low chronic exposure level. The environmental occurrences and sources of these contaminants in the water, soil, sediment and biota in European nations and the United States are well documented. This work reports a screening-level emission and fate assessment of thirty compounds, listed in the National Reconnaissance of the United States Geological Survey (USGS, 1999–2000 as the most frequently detected organic wastewater contaminants in U.S. streams and rivers. Estimations of the surface water fate factors were based on Level II and Level III multimedia fugacity models for a 1000 km2 model environment, the size of a typical county in the eastern United States. The compounds are categorized into three groups based upon the sensitivity of their predicted surface water fate factors to uncertainties in their physicochemical property values and the landscape parameters. The environmental fate factors, mass distributions, and loss pathways of all of the compounds are strongly affected by their assumed modes of entry into the environment. It is observed that for thirteen of the thirty organic wastewater contaminants most commonly detected in surface waters, conventional treatment strategies may be ineffective for their removal from wastewater effluents. The surface water fate factors predicted by the fugacity models were used in conjunction with the surface water concentrations measured in the USGS reconnaissance to obtain emission flux estimates for the compounds into U.S. streams and rivers. These include estimated fluxes of 6.8 × 10−5 to 0.30 kg/h km2 for the biomarker coprostanol; 1.7 × 10−5 to 6.5 × 10−5 kg/h km2 for the insect repellent N,N-diethyltoluamide; and 4.3 × 10−6 to 3.1 × 10−5 kg/h km2 for

  8. Surface contamination to UV-curable acrylates in the furniture and parquet industry.

    Science.gov (United States)

    Surakka, J; Lindh, T; Rosén, G; Fischer, T

    2001-03-01

    Surface contamination to ultraviolet radiation curable coatings (UV coatings), used increasingly in the parquet and furniture industry, is a matter of concern as a source for skin contamination. UV coatings contain chemically and biologically reactive acrylates, well known as skin contact irritants and sensitizers. Surface contamination may spread secondarily to equipment and other unexpected areas even outside the workplace. Yet, studies concerning this type of contamination are lacking due to lack of suitable sampling methods. Surface contamination of the work environment with risk for skin exposure to UV coating was measured employing a quantitative adhesive tape sampling method developed for this purpose. A pilot study was first performed at three workplaces to evaluate the contamination. In the main study, we wanted to locate and identify in detail the surface contamination of areas where problems exist, and to determine the extent of the problem. Measurements were performed at seven workplaces on two separate workdays (round 1 and 2) within a six-month period. Samples were collected from the workplaces based on the video monitoring of skin contact frequency with the surfaces and categorized into three groups to analyze risk. The pilot study indicated that surface contamination to TPGDA containing UV coatings was common, found in 76 percent of the surfaces, and varied with a maximum of 909 microg TPGDA 10 cm(-2) sampling area. In the main study TPGDA was found in 153 out of 196 collected samples (78.1%); for round one 78.1 percent (82 out of 105 samples) and for round two 78.0 percent (71 out of 91 samples). The average TPGDA mass on positive surface samples was on the first round 2,247 +/- 7,462 microg, and on the second round 2,960 +/- 4,590 microg. We conclude that surface contamination to uncured UV coatings at UV-curing lines is common and this involves a risk for harmful, unintentional skin exposure to acrylates.

  9. Decommissioning high-level waste surface facilities

    International Nuclear Information System (INIS)

    1978-04-01

    The protective storage, entombment and dismantlement options of decommissioning a High-Level Waste Surface Facility (HLWSF) was investigated. A reference conceptual design for the facility was developed based on the designs of similar facilities. State-of-the-art decommissioning technologies were identified. Program plans and cost estimates for decommissioning the reference conceptual designs were developed. Good engineering design concepts were on the basis of this work identified

  10. Vegetated Treatment Systems for Removing Contaminants Associated with Surface Water Toxicity in Agriculture and Urban Runoff.

    Science.gov (United States)

    Anderson, Brian S; Phillips, Bryn M; Voorhees, Jennifer P; Cahn, Michael

    2017-05-15

    Urban stormwater and agriculture irrigation runoff contain a complex mixture of contaminants that are often toxic to adjacent receiving waters. Runoff may be treated with simple systems designed to promote sorption of contaminants to vegetation and soils and promote infiltration. Two example systems are described: a bioswale treatment system for urban stormwater treatment, and a vegetated drainage ditch for treating agriculture irrigation runoff. Both have similar attributes that reduce contaminant loading in runoff: vegetation that results in sorption of the contaminants to the soil and plant surfaces, and water infiltration. These systems may also include the integration of granulated activated carbon as a polishing step to remove residual contaminants. Implementation of these systems in agriculture and urban watersheds requires system monitoring to verify treatment efficacy. This includes chemical monitoring for specific contaminants responsible for toxicity. The current paper emphasizes monitoring of current use pesticides since these are responsible for surface water toxicity to aquatic invertebrates.

  11. Concrete decontamination: two innovative processes in response to surface or deep contamination

    International Nuclear Information System (INIS)

    CUER, F.; Nadai, A. de; Faure, S.

    2008-01-01

    To meet the future needs in the nuclear industry as regards dismantling and decommissioning, the LPAD (Laboratoire des Procedes Avances de Decontamination) develops new specific techniques to decontaminate concretes: the drying gel process adapted to surface contamination and the electrokinetics process to treat deep contamination. Indeed, because the concrete constitute a porous medium, two types of contamination can be met according to the environment to which is subjected the material. In the case of an accidental or dry contamination, radio elements do not penetrate beyond the first millimeters of the material. The contamination is then considered as surface. On the contrary, the contamination is considered as 'deep' when radioactive ions have diffused deeply under the effects of the natural diffusion. This is the case in fuel storage pond or other many nuclear infrastructures. (authors)

  12. Plastic deformation to enhance plasma-assisted nitriding: On surface contamination induced by Surface Mechanical Attrition Treatment

    International Nuclear Information System (INIS)

    Samih, Youssef; Novelli, Marc; Bolle, Bernard; Allain, Nathalie; Fundenberger, Jean-Jacques; Marcos, Grégory; Czerwiec, Thierry; Grosdidier, Thierry; Thiriet, Tony

    2014-01-01

    The Surface Mechanical Attrition Treatment is a recent technique leading to the formation of nanostructured layers by the repeated action of impacting balls. While several communications have revealed possible contamination of the SMATed surfaces, the nature of this surface contamination was analyzed in the present contribution for the treatment of an AISI 316L stainless steel. It is shown, by a combination of Transmission Electron Microscopy and Glow Discharge – Optical Emission Spectrometry, that the surface was alloyed with Ti, Al and V coming from the sonotrode that is used to move the balls as well as Zr coming from the zirshot® balls themselves

  13. Plastic deformation to enhance plasma-assisted nitriding: On surface contamination induced by Surface Mechanical Attrition Treatment

    Science.gov (United States)

    Samih, Youssef; Novelli, Marc; Thiriet, Tony; Bolle, Bernard; Allain, Nathalie; Fundenberger, Jean-Jacques; Marcos, Grégory; Czerwiec, Thierry; Grosdidier, Thierry

    2014-08-01

    The Surface Mechanical Attrition Treatment is a recent technique leading to the formation of nanostructured layers by the repeated action of impacting balls. While several communications have revealed possible contamination of the SMATed surfaces, the nature of this surface contamination was analyzed in the present contribution for the treatment of an AISI 316L stainless steel. It is shown, by a combination of Transmission Electron Microscopy and Glow Discharge - Optical Emission Spectrometry, that the surface was alloyed with Ti, Al and V coming from the sonotrode that is used to move the balls as well as Zr coming from the zirshot® balls themselves.

  14. Measurements of the spatial distribution of tritium in air above a chronically contaminated surface

    International Nuclear Information System (INIS)

    Workman, W.J.G.; Davis, P.A.; Wood, M.J.; Barry, P.J.

    1993-01-01

    Tritium in air (HTO) concentrations were measured over a 13 month period above a surface that is chronically contaminated by tritium-bearing groundwater from a waste management area. The measurements were made using passive diffusion samplers, which were sited at six locations (about 100 m apart) at 0.15, 0.9, and 1.8 m above ground level. The diffusion samplers were compact, sampled at a known rate, and required no external power source. They are ideal for remote locations and require a minimum of effort to collect and analyze the data. HTO-in-air concentration peaked in the summer at 500-1500 Bq.m -3 and decreased in the winter to 1-120 Bq.m -3 . In general, concentration decreased with height above ground level, implying that HTO is being lost from the surface to the atmosphere. The flux of tritium to the atmosphere must, therefore, be taken into account to estimate the tritium mass balance for a contaminated area. (Author) 3 figs., 5 tabs., 10 refs

  15. A criterion of contamination of the glass surface of photovoltaic batteries

    International Nuclear Information System (INIS)

    Tursunov, M.N.; Dyskin, V.G.; Yuldashev, I.A. et al.; Park Jeong Hwoan

    2015-01-01

    The relative change in the coefficient of efficiency is chosen as a criterion for contamination of the glass surface of a photovoltaic battery. Using the formula obtained, the results of measurements of the transmission coefficient of a contaminated glass plate after its exposure to open air in the center of Tashkent for 80 and 110 days are processed. It is shown that the contamination of the glass plate reduces the coefficient of efficiency of the PVB by 50.0%. (authors)

  16. Bioremediation of hydrocarbon contaminated surface water, groundwater, and soils

    International Nuclear Information System (INIS)

    Piotrowski, M.R.

    1991-01-01

    Bioremediation is currently receiving considerable attention as a remediation option for sites contaminated with hazardous organic compounds. There is an enormous amount of interest in bioremediation, and numerous journals now publish research articles concerning some aspect of the remediation approach. A review of the literature indicates that two basic forms of bioremediation are currently being practiced: the microbiological approach and the microbial ecology approach. Each form has its advocates and detractors, and the microbiological approach is generally advocated by most of the firms that practice bioremediation. In this paper, the merits and disadvantages of these forms are reviewed and a conceptual approach is presented for assessing which form may be most useful for a particular contaminant situation. I conclude that the microbial ecology form of bioremediation may be the most useful for the majority of contaminant situations, and I will present two case histories in support of this hypothesis

  17. Laboratory Studies on Surface Sampling of Bacillus anthracis Contamination: Summary, Gaps, and Recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F.; Amidan, Brett G.; Hu, Rebecca

    2011-11-28

    This report summarizes previous laboratory studies to characterize the performance of methods for collecting, storing/transporting, processing, and analyzing samples from surfaces contaminated by Bacillus anthracis or related surrogates. The focus is on plate culture and count estimates of surface contamination for swab, wipe, and vacuum samples of porous and nonporous surfaces. Summaries of the previous studies and their results were assessed to identify gaps in information needed as inputs to calculate key parameters critical to risk management in biothreat incidents. One key parameter is the number of samples needed to make characterization or clearance decisions with specified statistical confidence. Other key parameters include the ability to calculate, following contamination incidents, the (1) estimates of Bacillus anthracis contamination, as well as the bias and uncertainties in the estimates, and (2) confidence in characterization and clearance decisions for contaminated or decontaminated buildings. Gaps in knowledge and understanding identified during the summary of the studies are discussed and recommendations are given for future studies.

  18. Exploring Surface Analysis Techniques for the Detection of Molecular Contaminants on Spacecraft

    Science.gov (United States)

    Rutherford, Gugu N.; Seasly, Elaine; Thornblom, Mark; Baughman, James

    2016-01-01

    Molecular contamination is a known area of concern for spacecraft. To mitigate this risk, projects involving space flight hardware set requirements in a contamination control plan that establishes an allocation budget for the exposure of non-volatile residues (NVR) onto critical surfaces. The purpose of this work will focus on non-contact surface analysis and in situ monitoring to mitigate molecular contamination on space flight hardware. By using Scanning Electron Microscopy and Energy Dispersive Spectroscopy (SEM-EDS) with Raman Spectroscopy, an unlikely contaminant was identified on space flight hardware. Using traditional and surface analysis methods provided the broader view of the contamination sources allowing for best fit solutions to prevent any future exposure.

  19. Conformational change of oil contaminants adhered onto crystalline alpha-alumina surface in aqueous solution

    International Nuclear Information System (INIS)

    Xie, Wenkun; Sun, Yazhou; Liu, Haitao; Fu, Hongya; Liang, Yingchun

    2016-01-01

    Graphical abstract: - Highlights: • Dynamic conformational change process of oil contaminations adhered onto Al-terminated α-Al_2O_3 surface in aqueous solution is given. • Effect of water penetration on the conformational change and even detachment of oil contaminants is considered. • Change of driving forces leading to the conformational change of oil contaminants is described. - Abstract: Microscopic conformational change of oil contaminants adhered onto perfect α-Al_2O_3 (0001) surface in the aqueous solution was simulated by means of detailed fully atomistic molecular dynamics simulations. The main driving forces of the conformation change process of the oil contaminants were explored. The simulation results indicate that with submerging of the contaminated α-Al_2O_3 (0001) surface into the aqueous solution, the oil contaminants undertake an evident conformational change process. The dynamic process can be divided into several stages, including early penetration of water molecules, formation and widening of water channel, and generation of molecularly adsorbed hydration layers. Moreover, the oil contaminants on the α-Al_2O_3 surface are not fully removed from solid surface after a 10 ns relaxation, while a relatively stable oil/water/solid three-phase interface is gradually formed. Further, the residual oil contaminants are finally divided into several new ordered molecular adsorption layers. In addition, by systemically analyzing the driving forces for the conformational change of the oil contaminants, the penetration of water molecules is found to be the most important driving force. With penetrating of the water molecules, the dominating interactions controlling the conformational change of the oil contaminants have been changing over the whole simulation.

  20. Molecular-Level Processes Governing the Interaction of Contaminants with Iron and Manganese Oxides - Final Report; FINAL

    International Nuclear Information System (INIS)

    Brown, G. E. Jr.; Chambers, S. A.

    1999-01-01

    Many of the inorganic and organic contaminants present in sediments at DOE sites can be altered or destroyed by reduction and oxidation (redox) reactions occurring at mineral surfaces. A fundamental understanding of such redox processes provided by molecular-level studies on structurally and compositionally well-defined mineral surfaces will lead to: (i) improved models of contaminant fate and transport in geochemical systems, and (ii) optimized manipulation of these processes for remediation purposes. To contribute to this understanding, we will study, both experimentally and theoretically, redox processes involving three important contaminants - chromate ion, carbon tetrachloride, and trichloroethene TCE, on the following iron and manganese oxides - hematite, magnetite, maghemite, and pyrolusite. These oxides and their hydroxylated analogs commonly occur as coatings on minerals or as interfaces in the subsurface environment. Single-crystal surfaces of these oxides will be synthesized in carefully controlled fashion by molecular beam epitaxy. These surfaces, as well as high surface are powdered samples of these oxides, will be used in spectroscopic and kinetic experiments in both aqueous and gas phases. Our goal is to identify products and to determine the kinetics and mechanisms of surface-catalyzed redox reaction of Cr(VI) and CR(III), and the reductive dechlorination of carbon tetrachloride and TCE. The combination of theory and experiment will provide the base information needed to scale from the molecular level to the microscopic grain level minerals

  1. Soil contamination of plant surfaces from grazing and rainfall interactions

    International Nuclear Information System (INIS)

    Hinton, T.G.; Stoll, J.M.; Tobler, L.

    1995-01-01

    Contaminants often attach to soil particles, and their subsequent environmental transport is largely determined by processes that govern soil movement. We examined the influence of grazing intensity on soil contamination of pastures. Four different grazing densities of sheep were tested against an ungrazed control plot. Scandium concentrations were determined by neutron activation analysis and was used as a tracer of soil adhesion on vegetation. Soil loadings ( g soil kg -1 dry plant) increased 60% when grazing intensity was increased by a factor of four (p 0.003). Rain and wind removed soil from vegetation in the ungrazed control plots, but when grazing sheep were present, an increase in rain from 0.3 to 9.7 mm caused a 130% increase in soil contamination. Multiple regression was used to develop an equation that predicts soil loadings as a function of grazing density, rainfall and wind speed (p = 0.0001, r 2 = 0.78). The model predicts that if grazing management were to be used as a tool to reduce contaminant intake from inadvertent consumption of resuspended soil by grazing animals, grazing densities would have to be reduced 2.5 times to reduce soil loadings by 50%. (author)

  2. Metal Hydride assited contamination on Ru/Si surfaces

    NARCIS (Netherlands)

    Pachecka, Malgorzata; Lee, Christopher James; Sturm, Jacobus Marinus; Bijkerk, Frederik

    2013-01-01

    In extreme ultraviolet lithography (EUVL) residual tin, in the form of particles, ions, and atoms, can be deposited on nearby EUV optics. During the EUV pulse, a reactive hydrogen plasma is formed, which may be able to react with metal contaminants, creating volatile and unstable metal hydrides that

  3. Radioactive air and surface contamination in Czechia and Slovakia

    International Nuclear Information System (INIS)

    Rumyantsev, V.V.

    1992-01-01

    Data are presented on the radioactive substance effluents into the environment in conditions of NPP normal operation and on the air contamination by 85 Kr due to operation of the European and Soviet plants for reprocessing spent nuclear fuel. Data are given on the dosage of the Czechoslovakia population due to the Chernobyl NPP accident

  4. Microbial Contamination Level Profiles Attributed to Contamination of Beef Carcasses, Personnel, and Equipment: Case of Small and Medium Enterprise Slaughterhouses.

    Science.gov (United States)

    Wambui, Joseph; Lamuka, Peter; Karuri, Edward; Matofari, Joseph; Njage, Patrick Murigu Kamau

    2018-04-01

    The microbial contamination level profiles (MCLPs) attributed to contamination of beef carcasses, personnel, and equipment in five Kenyan small and medium enterprise slaughterhouses were determined. Aerobic plate counts, Enterobacteriaceae, Staphylococcus, and Salmonella were used to determine contamination at four different slaughter stages, namely, dehiding, evisceration, splitting, and dispatch. Microbiological criteria of the four microorganisms were used to score contamination levels (CLs) as poor (0), poor to average (1), average (2), or good (3). MCLPs were further assigned to carcasses, personnel, and equipment at each stage by summing up the CL scores. The CL score attributed to aerobic plate count contamination was 2 or 3 for carcasses but 0 for personnel and equipment in almost all slaughterhouses. A score of 0 on carcasses was mostly attributed to Enterobacteriaceae at evisceration and to Salmonella at dehiding and evisceration. In addition, a score of 0 was mostly attributed to Staphylococcus contamination of personnel at dehiding. A score of 3 was attributed mostly to Enterobacteriaceae on hands at splitting, whereas a score of 2 was mostly attributed to the clothes at dehiding and evisceration. A CL score of 3 was mostly attributed to Enterobacteriaceae and Salmonella contamination of equipment at dehiding and splitting, respectively. Although CLs attributed to contamination of carcasses, personnel, and equipment ranged from 0 to 3, the maximum MCLP score of 9 was only attained in carcasses from two slaughterhouses at dehiding and from one slaughterhouse at dispatch. There is, therefore, a lot of room for small and medium enterprise slaughterhouses to improve their food safety objectives by improving food safety management systems at the points characterized by low CL scores.

  5. Nuclear electronic components of surface contamination monitor based on multi-electrode proportional counter

    International Nuclear Information System (INIS)

    Du Xiangyang; Zhang Yong; Han Shuping; Rao Xianming; Fang Jintu

    2001-01-01

    The nuclear electronic components applying in Portal Monitor and Hands and Feet Surface Contamination Monitor were based on modern integrated circuit are introduced. The detailed points in circuit design and manufacturing technique are analyzed

  6. Effect of surface contamination on osseointegration of dental implants surrounded by circumferential bone defects.

    LENUS (Irish Health Repository)

    Mohamed, Seif

    2010-05-01

    This study was designed to evaluate the effect of surface contamination on osseointegration of dental implants surrounded by a circumferential bone defect and to compare osseointegration around Osseotite with that around Nanotite implants.

  7. National Enforcement Initiative: Preventing Animal Waste from Contaminating Surface and Ground Water

    Science.gov (United States)

    This page describes EPA's goal in preventing animal waste from contaminating surface and ground Water. It is an EPA National Enforcement Initiative. Both enforcement cases, and a map of enforcement actions are provided.

  8. A prospective survey of air and surface fungal contamination in a medical mycology laboratory at a tertiary care university hospital.

    Science.gov (United States)

    Sautour, Marc; Dalle, Frédéric; Olivieri, Claire; L'ollivier, Coralie; Enderlin, Emilie; Salome, Elsa; Chovelon, Isabelle; Vagner, Odile; Sixt, Nathalie; Fricker-Pap, Véronique; Aho, Serge; Fontaneau, Olivier; Cachia, Claire; Bonnin, Alain

    2009-04-01

    Invasive filamentous fungi infections resulting from inhalation of mold conidia pose a major threat in immunocompromised patients. The diagnosis is based on direct smears, cultural symptoms, and culturing fungi. Airborne conidia present in the laboratory environment may cause contamination of cultures, resulting in false-positive diagnosis. Baseline values of fungal contamination in a clinical mycology laboratory have not been determined to date. A 1-year prospective survey of air and surface contamination was conducted in a clinical mycology laboratory during a period when large construction projects were being conducted in the hospital. Air was sampled with a portable air system impactor, and surfaces were sampled with contact Sabouraud agar plates. The collected data allowed the elaboration of Shewhart graphic charts. Mean fungal loads ranged from 2.27 to 4.36 colony forming units (cfu)/m(3) in air and from 0.61 to 1.69 cfu/plate on surfaces. Strict control procedures may limit the level of fungal contamination in a clinical mycology laboratory even in the context of large construction projects at the hospital site. Our data and the resulting Shewhart graphic charts provide baseline values to use when monitoring for inappropriate variations of the fungal contamination in a mycology laboratory as part of a quality assurance program. This is critical to the appropriate management of the fungal risk in hematology, cancer and transplantation patients.

  9. Allowable Residual Contamination Levels in soil for decommissioning the Shippingport Atomic Power Station site

    International Nuclear Information System (INIS)

    Kennedy, W.E. Jr.; Napier, B.A.; Soldat, J.K.

    1983-09-01

    As part of decommissioning the Shippingport Atomic Power Station, a fundamental concern is the determination of Allowable Residual Contamination Levels (ARCL) for radionuclides in the soil at the site. The ARCL method described in this report is based on a scenario/exposure-pathway analysis and compliance with an annual dose limit for unrestricted use of the land after decommissioning. In addition to naturally occurring radionuclides and fallout from weapons testing, soil contamination could potentially come from five other sources. These include operation of the Shippingport Station as a pressurized water reactor, operations of the Shippingport Station as a light-water breeder, operation of the nearby Beaver Valley reactors, releases during decommissioning, and operation of other nearby industries, including the Bruce-Mansfield coal-fired power plants. ARCL values are presented for 29 individual radionculides and a worksheet is provided so that ARCL values can be determined for any mixture of the individual radionuclides for any annual dose limit selected. In addition, a worksheet is provided for calculating present time soil concentration value that will decay to the ARCL values after any selected period of time, such as would occur during a period of restricted access. The ARCL results are presented for both unconfined (surface) and confined (subsurface) soil contamination. The ARCL method and results described in this report provide a flexible means of determining unrestricted-use site release conditions after decommissioning the Shippingport Atomic Power Station

  10. LEVEL AND EXTENT OF MERCURY CONTAMINATION IN OREGON LOTIC FISH

    Science.gov (United States)

    As part of the U.S. EPA's EMAP Oregon Pilot project, we conducted a probability survey of 154 Oregon streams and rivers to assess the spatial extent of mercury (Hg) contamination in fish tissue across the state. Samples consisted of whole fish analyses of both small (< 120 mm) a...

  11. Evaluation and assessment of baseline metal contamination in surface sediments from the Bernam River, Malaysia.

    Science.gov (United States)

    Kadhum, Safaa A; Ishak, Mohd Yusoff; Zulkifli, Syaizwan Zahmir

    2016-04-01

    The Bernam River is one of the most important rivers in Malaysia in that it provides water for industries and agriculture located along its banks. The present study was conducted to assess the level of contamination of heavy metals (Cd, Ni, Cr, Sn, and Fe) in surface sediments in the Bernam River. Nine surface sediment samples were collected from the lower, middle, and upper courses of the river. The results indicated that the concentrations of the metals decreased in the order of Sn > Cr > Ni > Fe > Cd (56.35, 14.90, 5.3, 4.6, and 0.62 μg/g(1) dry weight). Bernam River sediments have moderate to severe enrichment for Sn, moderate for Cd, and no enrichment for Cr, Ni, and Fe. The contamination factor (CF) results demonstrated that Cd and Sn are responsible for the high contamination. The pollution load index (PLI), for all the sampling sites, suggests that the sampling stations were generally unpolluted with the exception of the Bagan Tepi Sungai, Sabak Bernam, and Tanjom Malim stations. Multivariate techniques including Pearson's correlation and hierarchical cluster analysis were used to apportion the various sources of the metals. The results suggested that the sediment samples collected from the upper course of the river had lower metal concentrations, while sediments in the middle and lower courses of the river had higher metal concentrations. Therefore, our results can be useful as a baseline data for government bodies to adopt corrective measure on the issues related to heavy metal pollution in the Bernam River in the future.

  12. Combined Contamination and Space Environmental Effects on Solar Cells and Thermal Control Surfaces

    Science.gov (United States)

    Dever, Joyce A.; Bruckner, Eric J.; Scheiman, David A.; Stidham, Curtis R.

    1994-01-01

    For spacecraft in low Earth orbit (LEO), contamination can occur from thruster fuel, sputter contamination products and from products of silicone degradation. This paper describes laboratory testing in which solar cell materials and thermal control surfaces were exposed to simulated spacecraft environmental effects including contamination, atomic oxygen, ultraviolet radiation and thermal cycling. The objective of these experiments was to determine how the interaction of the natural LEO environmental effects with contaminated spacecraft surfaces impacts the performance of these materials. Optical properties of samples were measured and solar cell performance data was obtained. In general, exposure to contamination by thruster fuel resulted in degradation of solar absorptance for fused silica and various thermal control surfaces and degradation of solar cell performance. Fused silica samples which were subsequently exposed to an atomic oxygen/vacuum ultraviolet radiation environment showed reversal of this degradation. These results imply that solar cells and thermal control surfaces which are susceptible to thruster fuel contamination and which also receive atomic oxygen exposure may not undergo significant performance degradation. Materials which were exposed to only vacuum ultraviolet radiation subsequent to contamination showed slight additional degradation in solar absorptance.

  13. Methods for the calculation of derived working limits for surface contamination by low-toxicity radionuclides

    International Nuclear Information System (INIS)

    Gibson, J.A.B.; Wrixon, A.D.

    1979-01-01

    Surface contamination is often measured as an indication of the general spread of radioactive contamination in a particular place. Derived working limits, (DWLs) for surface contamination provide figures against which to assess the significance of measurements. Derived working limits for surface contamination were first established for use in the nuclear energy industry. They were designed to cope with a wide range of unspecified radionuclides and were therefore based on the assumption that the contamination was due to the presence of the most hazardous radionuclides, e.g. 90 Sr, 210 Pb, 226 Ra and 239 Pu. While this assumption may still be appropriate when the radionuclide mixture is unknown, there are now many specialized uses of particular low-toxicity radionuclides in universities, hospitals and general industry. If it is known that only a particular radionuclide is present, the general DWL can be replaced by a more specific value. The methods for calculating DWLs for some of the more commonly employed low-toxicity radionuclides are described. The exposure pathways considered are (a) external radiation of the skin and inhalation of airborne material from contaminated surfaces in active areas; (b) external irradiation of the skin and ingestion from contaminated skin. Some consideration is given to the effect of the revised dose equivalent limits in the most recent recommendations of ICRP. (author)

  14. Effects of decontamination at varying contamination levels of Campylobacter jejuni on broiler meat

    DEFF Research Database (Denmark)

    Boysen, Louise; Wechter, Naja Strandby; Rosenquist, Hanne

    2013-01-01

    /sample) or single or few strains of the species (or both) should not be interpreted as a generic result for the species. If inoculation studies cannot be replaced by investigations of naturally contaminated meat, we advise using a mixture of strains found in the production environment at levels as close as possible...... to the natural contamination level....

  15. Evaluation of surface contamination due to alpha using large area contamination monitors

    International Nuclear Information System (INIS)

    Raghavayya, M.

    1998-01-01

    Radioactive contamination at work places is evaluated routinely using either the swipe sampling technique or a contamination monitor. Commercially available alpha probes used for the purpose are usually circular and have a face diameter of 50 or 100 mm. Square faced probes are also available. A thin aluminized mylar membrane of thickness 0.45 to 0.9 mg.cm -2 is used to screen the phosphor in the alpha probe to protect it from external light. The membrane cuts off more alphas from low energy emitters than from higher energy alpha emitters. Moreover the response of the detector for alphas originating at all points under the detector face is not uniform, especially when the large area alpha monitors are used. These factors can introduce errors as high as 40% into the measurements. This paper aims to quantify these errors and describe a procedure to overcome the limitations. (author)

  16. EM Task 12 - Laser cleaning of Contaminated Painted Surfaces

    International Nuclear Information System (INIS)

    Ames A. Grisanti; Charlene R. Crocker; Robert J. Jensen

    1998-01-01

    Several techniques are available or under development for surface decontamination in nuclear facilities. Each technique has its merits; however, none of them is universally the best choice for all surface decontamination applications. Because of the multitude of factors which influence the environmental and economic aspects of selecting a surface decontamination technique, it is difficult to select the best method in a given situation; an objective basis for comparing techniques is needed. The objective of this project is to develop a software tool for use by personnel selecting a surface decontamination technique. The software will incorporate performance data for available surface decontamination techniques. The beta release of the Surface Decontamination Assistant Software has been completed and has undergone testing at the Energy and Environmental Research Center (EERC). Minor modifications to the software will be completed before the end of November 1998, and a final release of the software will be issued

  17. EM Task 12 - Laser cleaning of contaminated painted surfaces

    International Nuclear Information System (INIS)

    Grisanti, Ames A.; Crocker, Charlene R.; Jensen, Robert R.

    1999-01-01

    Several techniques are available or under development for surface decontamination in nuclear facilities. Each technique has its merits; however, none of them is universally the best choice for all surface decontamination applications. Because of the multitude of factors which influence the environmental and economic aspects of selecting a surface decontamination technique, it is difficult to select the best method in a given situation; an objective basis for comparing techniques is needed. The objective of this project was to develop a software tool for use by personnel selecting a surface decontamination technique. The software incorporates performance data for available surface decontamination techniques. The beta release version of the Surface Decontamination Assistant Software has been completed and has undergone testing at the Energy and Environmental Research Center. Minor modifications to the software were completed, and a final release version of the software is ready to be issued

  18. Study of surface potential contamination in radioisotope and radiopharmaceutical production facilities and alternative solutions

    International Nuclear Information System (INIS)

    Suhaedi Muhammad; Rimin Sumantri; Farida Tusafariah; Djarwanti Rahayu Pipin Soedjarwo

    2013-01-01

    Radioisotope and radiopharmaceutical production facilities that exist in their operations around the world in the form of radiological impacts of radiation exposure, contamination of surface and air contamination. Given the number of existing open source in radioisotope and radiopharmaceutical production facility, then the possibility of surface contamination in the work area is quite high. For that to protect the safety and health of both workers, the public and the environment, then the licensee must conduct an inventory of some of the potential that could result in contamination of surfaces in radioisotope and radiopharmaceutical production facilities. Several potential to cause surface contamination in radioisotope and radiopharmaceutical production facilities consist of loss of resources, the VAC system disorders, impaired production facilities, limited resources and lack of work discipline and radioactive waste handling activities. From the study of some potential, there are several alternative solutions that can be implemented by the licensee to address the contamination of the surface so as not to cause adverse radiological impacts for both radiation workers, the public or the environment. (author)

  19. Assessment of the contaminants level in recycled aggregates and alternative new technologies for contaminants recognition and removal

    NARCIS (Netherlands)

    Lotfi, S.; Di Maio, F.; Xia, H.; Serranti, S.; Palmieri, R.; Bonifazi, G.

    2015-01-01

    One of the main challenging problems associated with the use of Recycled Aggregates (RA) is the level of mixed contaminants. For utilizing RA in high-grade applications, it is essential to monitor and minimise the content of the pollutants. To this extent the C2CA concrete recycling process

  20. Atmospheric-Pressure Plasma Cleaning of Contaminated Surfaces

    International Nuclear Information System (INIS)

    Hicks, Robert F.; Herrmann, Hans W.

    2003-01-01

    The objective of this work is to demonstrate a practical, atmospheric pressure plasma tool for the surface decontamination of radioactive waste. Decontamination of radioactive materials that have accumulated on the surfaces of equipment and structures is a challenging and costly undertaking for the US Department of Energy. Our technology shows great potential for accelerating this clean up effort

  1. Contamination of Optical Surfaces Under Irradiation by Outgassed Volatile Products

    International Nuclear Information System (INIS)

    Khasanshin, R. H.; Grigorevskiy, A. V.; Galygin, A. N.; Alexandrov, N. G.

    2009-01-01

    Deposition of outgassed products of a polymeric composite on model material surfaces being irradiated by electrons and protons with initial energies of E e = 40 keV and E p = 30 keV respectively was studied. It was shown that deposition of volatile products on model material surfaces being under ionizing radiations results in increase of organic film growth rate.

  2. Secondary radioactive contamination of the Black Sea after Chernobyl accident: recent levels, pathways and trends

    International Nuclear Information System (INIS)

    Gulin, S.B.; Mirzoyeva, N.Yu.; Egorov, V.N.; Polikarpov, G.G.; Sidorov, I.G.; Proskurnin, V.Yu.

    2013-01-01

    The recent radionuclide measurements have showed that concentrations of the Chernobyl-derived 137 Cs and 90 Sr in the surface Black Sea waters are still relatively high, reaching 56 and 32 Bq m −3 , respectively. This is comparable or even exceeds the pre-Chernobyl levels (∼16 Bq 137 Cs and 22 Bq 90 Sr per m 3 as the basin-wide average values). The measurements have revealed that the Black Sea continues to receive Chernobyl radionuclides, particularly 90 Sr, by the runoff from the Dnieper River. An additional source of 90 Sr and 137 Cs was found in the area adjacent to the Kerch Strait that connects the Black Sea and the Sea of Azov. This may be caused by the inflow of the contaminated Dnieper waters, which come to this area through the North-Crimean Canal. The long-term monitoring of 137 Cs and 90 Sr concentration in the Black Sea surface waters and in the benthic brown seaweed Cystoseira sp., in comparison with the earlier published sediment records of the radionuclides, have showed signs of a secondary radioactive contamination, which has started to increase since the late 1990's. This may be the result of the combined effect of a higher input of radionuclides from the rivers in 1995–1999 due to an increased runoff; and a slow transport of the particulate bound radionuclides from the watersheds followed by their desorption in seawater from the riverine suspended matter and remobilization from the sediments adjacent to the river mouths. -- Highlights: • Concentration of 137 Cs and 90 Sr in the Black Sea water is still relatively high. • The Black Sea continues to receive considerable radionuclide amount from the rivers. • The North-Crimean Canal is significant source of the Black Sea radioactivity. • Secondary radioactive contamination of the Black Sea increased in the late 1990's. • Radionuclide remobilization from sediments leads to a further Black Sea pollution

  3. Comparative analyses of contaminant levels in bottom feeding and predatory fish using the National Contaminant Biomonitoring Program data

    Energy Technology Data Exchange (ETDEWEB)

    Kidwell, J.M. [Clement International Corp., Fairfax, VA (United States); Phillips, L.J. [Versar Inc., Springfield, VA (United States); Birchard, G.F. [George Mason Univ., Fairfax, VA (United States)

    1995-06-01

    Both bottom feeding and predatory fish accumulate chemical contaminants found in water. Bottom feeders are readily exposed to the greater quantities of chlorinated hydrocarbons and metals that accumulate in sediments. Predators, on the other hand, may bioaccumulate organochlorine pesticides, PCBs, and metals from the surrounding water or from feeding on other fish, including bottom feeders, which may result in the biomagnification of these compounds in their tissues. This study used National Contaminant Biomonitoring Program data produced by the Fish and Wildlife Service to test the hypothesis that differences exist between bottom feeders and predators in tissue levels of organochlorine pesticides, PCBs, and metals. 7 refs., 2 tabs.

  4. Regional contamination versus regional dietary differences: Understanding geographic variation in brominated and chlorinated contaminant levels in polar bears

    Science.gov (United States)

    McKinney, M.A.; Letcher, R.J.; Aars, Jon; Born, E.W.; Branigan, M.; Dietz, R.; Evans, T.J.; Gabrielsen, G.W.; Muir, D.C.G.; Peacock, E.; Sonne, C.

    2011-01-01

    The relative contribution of regional contamination versus dietary differences to geographic variation in polar bear (Ursus maritimus) contaminant levels is unknown. Dietary variation between Alaska Canada, East Greenland, and Svalbard subpopulations was assessed by muscle nitrogen and carbon stable isotope (?? 15N, ?? 13C) and adipose fatty acid (FA) signatures relative to their main prey (ringed seals). Western and southern Hudson Bay signatures were characterized by depleted ?? 15N and ??13C, lower proportions of C20 and C22 monounsaturated FAs and higher proportions of C18 and longer chain polyunsaturated FAs. East Greenland and Svalbard signatures were reversed relative to Hudson Bay. Alaskan ?? 2011 American Chemical Society.

  5. Tritium contaminated surface monitoring with a solid - state device

    International Nuclear Information System (INIS)

    Culcer, Mihai; Iliescu, Mariana; Curuia, Marian; Enache, Adrian; Stefanescu, Ioan; Ducu, Catalin; Malinovschi, Viorel

    2004-01-01

    The low energy of betas makes tritium difficult to detect. However, there are several methods used in tritium detection, such as liquid scintillation and ionization chambers. Tritium on or near a surface can be also detected using proportional counters and, recently, solid state devices. The paper presents our results in the design and achievement of a surface tritium monitor using a PIN photodiode as a solid state charged particle detector to count betas emitted from the surface. That method allows continuous, real-time and non-destructively measuring of tritium. (authors)

  6. Management of commercial high-level and transuranium-contaminated radioactive wastes. Environmental statement

    International Nuclear Information System (INIS)

    1974-09-01

    This Draft Environmental Statement is issued to assess the environmental impact of the AEC's program to manage commercial high-level and transuranium-contaminated radioactive wastes. These are the types of commercial radioactive wastes for which AEC custody is required by present or anticipated regulations. The program consists of three basic parts: development of a Retrievable Surface Storage Facility (RSSF) for commercial high-level waste, using existing technology; evaluating geological formations and sites for the development of a Geological Disposal Pilot Plant (GDPP) which would lead to permanent disposal; and providing retrievable storage for the transuranium-contaminated waste pending availability of permanent disposal. Consideration has been given to all environmental aspects of the program, using waste generation projections through the year 2000. Radiological and other impacts of implementing the program are expected to be minimal, but will be discussed in further environmental statements which will support budget actions for specific repositories. The alternatives discussed in this Draft Environmental Statement are presented. (U.S.)

  7. Bond strength of resin-resin interfaces contaminated with saliva and submitted to different surface treatments

    Directory of Open Access Journals (Sweden)

    Adilson Yoshio Furuse

    2007-12-01

    Full Text Available The purpose of this study was to investigate the effect of different surface treatments on shear bond strength of saliva-contaminated resin-resin interfaces. Flat resin surfaces were fabricated. In the control group, no contamination or surface treatment was performed. The resin surfaces of the experimental groups were contaminated with saliva and air-dried, and then submitted to: (G1 rinsing with water and drying; (G2 application of an adhesive system; (G3 rinsing and drying, abrasion with finishing disks, etching and application of adhesive system; (G4 rinsing and drying, etching, application of silane and adhesive system. Resin cylinders were placed over the treated surfaces. The specimens were stored in water or ethanol. Shear bond strength tests were performed and the mode of failure was evaluated. Data were submitted to two-way ANOVA and Dunnett T3 test. Contamination of resin-resin interfaces with saliva significantly reduced shear strength, especially after prolonged storage (p<0.05. Similar values to the original bond strength were obtained after abrasion and application of adhesive (G3 or etching and application of silane and adhesive (G4. If contamination occurs, a surface treatment is required to guarantee an adequate interaction between the resin increments.

  8. Diamond blade grinding as a means for removing surface contamination from concrete

    International Nuclear Information System (INIS)

    Lynch, T.W.

    1980-01-01

    The use of a highway grinding unit for the decontamination of a 5,000 square foot surface is described. The type of equipment presently in use is described. Performance characteristics, waste collection and water usage are commented on. Variables in blade design are discussed. Feasibility of the grinding technique for water soluble contaminants and vertical surfaces is referred to

  9. Development of inspection techniques for quantitatively measuring surface contamination on SRM hardware

    Science.gov (United States)

    Law, R. D.

    1989-01-01

    A contaminant is any material or substance which is potentially undesirable or which may adversely affect any part, component, or assembly. Contamination control of SRM hardware surfaces is a serious concern, for both Thiokol and NASA, with particular concern for contaminants which may adversely affect bonding surfaces. The purpose of this study is to develop laboratory analytical techniques which will make it possible to certify the cleanliness of any designated surface, with special focus on particulates (dust, dirt, lint, etc.), oils (hydrocarbons, silicones, plasticizers, etc.), and greases (HD-2, fluorocarbon grease, etc.). The hardware surfaces of concern will include D6AC steel, aluminum alloys, anodized aluminum alloys, glass/phenolic, carbon/phenolic, NBR/asbestos-silica, and EPDM rubber.

  10. Fixation of soil surface contamination using natural polysaccharides

    International Nuclear Information System (INIS)

    Sackschewsky, M.R.

    1993-09-01

    Natural polysaccharides were evaluated as alternatives to commercially available dust-control agents for application in buried-waste and contaminated-soil remediation situations. Materials were identified and evaluated with specific criteria in mind: the materials must be environmentally benign and must not introduce any additional hazardous materials; they must be effective for at least 2 or 3 days, but they do not necessarily have to be effective for more than 2 to 3 weeks; they should be relatively resistant to light traffic; they must not interfere with subsequent soil treatment techniques, especially soil washing; and they must be relatively inexpensive. Two products, a pregelled potato starch and a mixture of carbohydrates derived from sugar beets, were selected for evaluation. Testing included small- and large-scale field demonstrations, laboratory physical property analyses, and wind-tunnel evaluations

  11. The Development of a Sub-Surface Monitoring System for Organic Contamination in Soils and Groundwater

    Directory of Open Access Journals (Sweden)

    Sharon L. Huntley

    2002-01-01

    Full Text Available A major problem when dealing with environmental contamination is the early detection and subsequent surveillance of the contamination. This paper describes the potential of sub-surface sensor technology for the early detection of organic contaminants in contaminated soils, sediments, and landfill sites. Rugged, low-power hydrocarbon sensors have been developed, along with a data-logging system, for the early detection of phase hydrocarbons in soil. Through laboratory-based evaluation, the ability of this system to monitor organic contamination in water-based systems is being evaluated. When used in conjunction with specific immunoassays, this can provide a sensitive and low-cost solution for long-term monitoring and analysis, applicable to a wide range of field applications.

  12. Klebsiella sp. FIRD 2, a TBT-resistant bacterium isolated from contaminated surface sediment along Strait of Johor Malaysia.

    Science.gov (United States)

    Abubakar, Abdussamad; Mustafa, Muskhazli B; Johari, Wan Lutfi Wan; Zulkifli, Syaizwan Zahmir; Ismail, Ahmad; Mohamat-Yusuff, Ferdaus Binti

    2015-12-15

    A possible tributyltin (TBT)-degrading bacterium isolated from contaminated surface sediment was successfully identified as Klebsiella sp. FIRD 2. It was found to be the best isolate capable of resisting TBT at a concentration of 1000 μg L(-1). This was a concentration above the reported contaminated level at the sampling station, 790 μg L(-1). Further studies revealed that the isolate was Gram negative and resisted TBT concentrations of up to 1500 μg L(-1) in a Minimal Salt Broth without the addition of any carbon source within the first 48 h of incubation. It is expected that additional work could be conducted to check the degradation activity of this new isolate and possibly improve the degradation capacity in order to contribute to finding a safe and sustainable remediation solution of TBT contamination. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Dispersion of inorganic contaminants in surface water in the vicinity of Potchefstroom

    Science.gov (United States)

    Manyatshe, A.; Fosso-Kankeu, E.; van der Berg, D.; Lemmer, N.; Waanders, F.; Tutu, H.

    2017-08-01

    Potchefstroom and the neighbouring cities rely mostly on the Mooi River and Vaal River for their water needs. These rivers flow through the gold mining areas and farms, and are therefore likely to be contaminated with substantial amounts of inorganic pollutants. Water was collected along the rivers network, streams, canals and dams in Potchefstroom and the vicinity. The samples were characterized for geochemical parameters, metals and anions concentrations. The results showed high concentrations of potentially toxic elements such as As (4.53 mg/L - 5.74 mg/L), Cd (0.25 mg/L - 0.7 mg/L), Pb (1.14 mg/L - 5.13 mg/L) and U (0.04 mg/L - 0.11 mg/L) which were predominantly found around the mining areas. Elevated concentrations of anions such SO42- and CN- were detected around mining areas while NO3- was dominant near farms. The relatively high levels of anions and metals in the surface water made it unfit for domestic or agricultural use. The study showed that contaminants in mining and agricultural facilities were potentially mobilised, thus impacting the nearby water systems.

  14. Investigation on the level and movement of Mercury contaminants around storage areas and food processing factories in Hassahesa town, Sudan

    International Nuclear Information System (INIS)

    Abdelrahman, Nawal Ahmed Mohamed

    1999-11-01

    A total of 62 surface soil samples were taken from various sites in Hassahesa town and analyzed for total mercury level using X-ray fluorescence spectrometer. Sites were chosen to represent the soil of pesticide store, food processing factories (involved in using contaminated seeds as fuel), near stock of redundant cotton seeds and neighbouring cotton fields. Control soils were sampled from similar soil type south Hassahesa town. The results indicated an elevated mercury level in all samples analyzed far exceeding the background and normal range for mercury in soil. The highest level of contamination was found in soil of the pesticide store (51ppm), followed by the tow food factories (24 ppm and 19 ppm). Horizontal movement of mercury contaminants at various rates from foci of area selected was noticed, wind direction and/ or topography apparently had some role in this movement. The level of total mercury in the control soil was exceeding the background and normal range for mercury in soils reported from other places. Various aspects of levels of mercury contamination, their movements, transportation and toxicological impacts on various forms of life were discussed.(Author)

  15. Investigation on the level and movement of mercury contaminants around storage areas and food processing factories in Hassahesa town

    International Nuclear Information System (INIS)

    Abdelrahman, Nawal Ahmed Mohamed

    1999-11-01

    A total of 62 surface soil samples were taken from various sites in Hassahesa town and analyzed for total mercury level using x-ray fluorescence spectrometer. Sites were chosen to represent the soil of pesticide store, food processing factories (involved in using contaminated seeds as fuel), nera stock of redundant cotton seeds and neighbouring cotton fields. Control soils were sampled from similar soil type south Hassahesa town. The results indicated an elevated mercury level in all samples analyzed far exceeding the background and normal range for mercury in soil. The highest level of contamination was found in soil of pesticide store (51 ppm), followed by the two food factories (24 ppm and 19 ppm). Horizontal movement of mercury contaminants at various rates from foci of areas selected was noticed, wind direction and/or topography apparently had some role in this movement. The level of total mercury in the control soil was exceeding the background and normal range for mercury in soils reported from other places. Various aspects of levels of mercury contamination, their movements, transportation and toxicological impacts on various forms of life were discussed. (Author)

  16. OPERATIONAL LIMITATIONS FOR DEMOLITION OF A HIGHLY ALPHA CONTAMINATED BUILDING MODLES VERSUS MEASURED AIR & SURFACE ACTIVITY CONCENTRATIONS

    Energy Technology Data Exchange (ETDEWEB)

    LLOYD, E.R.

    2006-11-02

    The demolition of a facility historically used for processing and handling transuranic materials is considered. Residual alpha emitting radionuclide contamination poses an exposure hazard if released to the local environment during the demolition. The process of planning for the demolition of this highly alpha contaminated building, 232-Z, included a predemolition modeling analysis of potential exposures. Estimated emission rates were used as input to an air dispersion model to estimate frequencies of occurrence of peak air and surface exposures. Postdemolition modeling was also conducted, based on the actual demolition schedule and conditions. The modeling results indicated that downwind deposition is the main operational limitation for demolition of a highly alpha-contaminated building. During the demolition of 232-Z, airborne radiation and surface contamination were monitored. The resultant non-detect monitoring results indicate a significant level of conservatism in the modeled results. This comparison supports the use of more realistic assumption in the estimating emission rates. The resultant reduction in modeled levels of potential exposures has significant implications in terms of the projected costs of demolition of such structures.

  17. Effects of steaming on contaminants of emerging concern levels in seafood

    DEFF Research Database (Denmark)

    Barbosa, Vera; Maulvault, Ana Luísa; Alves, Ricardo N

    2018-01-01

    in contaminant levels was observed after steaming, though varying according to contaminant and seafood species (e.g. iAs, perfluorobutanoate, dibenzo(ah)anthracene in Mytilus edulis, HHCB-Lactone in Solea sp., 2-Ethylhexyl salicylate in Lophius piscatorius). Furthermore, the increase in some CeCs, like Pb, Me...

  18. [Observation of topography and analysis of surface contamination of titanium implant after roughness treatment].

    Science.gov (United States)

    Cao, Hongdan; Yang, Xiaodong; Wu, Dayi; Zhang, Xingdong

    2007-04-01

    The roughness treatment of dental implant surface could improve the bone bonding and increase the success rate of implant, but the difference of diverse treatments is still unknown. In this study using scanning electron microscopy (SEM), energy disperse spectrometer (EDS) and the test of contact angle, we studied the microstructure, surface contamination and surface energy, and hence conducted a comparative analysis of the following surface roughness treatments: Polished Treatment (PT), Sandblasting with Alumina(SA), Sandblasting with Aluminia and Acid-etched (SAA), Sandblasting with Titanium Acid-etched (STA), Electro-erosion Treatment(ET). The result of SEM showed that the surface displayed irregularities after roughness treatments and that the surface properties of different roughness treatments had some distinctions. SAA and SA had some sharp edges and protrutions; the STA showed a regular pattern like honeycomb, but the ET sample treated by electric erosion exhibited the deeper pores of different sizes and the pores with a perforated secondary structure. The EDS indicated that the surface was contaminated after the treatment with foreign materials; the SA surface had some embedded contaminations even after acid etching. The measurement of water contact angle indicated that the morphology correlated with the surface treatments. These findings suggest that the distinction of surface structure and composition caused by different treatments may result in the disparity in biological behavior of dental implant.

  19. Surface sterilization method for reducing microbial contamination of ...

    African Journals Online (AJOL)

    An effective disinfection method for strawberry (Fragaria x ananassa Duch.) cv. Senga Sengana micropropagation using runner tips and nodal segments as explants was developed. The explants were surface sterilized with different sterilants for different durations. The present studies on the effect of different regimes of ...

  20. The development of the American national standard, ''control of radioactive surface contamination on materials, equipment and facilities to be released for uncontrolled use''

    International Nuclear Information System (INIS)

    Shapiro, J.

    1980-01-01

    The American National Standard, Control of Radioactive Surface Contamination on Materials, Equipment and Facilities to be Released for Uncontrolled Use, was developed under the procedures of ANSI for ANSI Main Committee N13 (Radiation Protection) by a working group of the Health Physics Society Standards Committee. This standard provides criteria for the control of materials, equipment and facilities contaminated with radioactivity proposed to be released for uncontrolled use. Permissible contamination limits are specified as well as methods assessing the levels of contamination. This paper reviews the proceedings of the Subcommittee on Radioactive Surface Contamination, the comments received by reviewers of the standard, the resolution of the committee, and the bases for reaching the final limits, recommendations, and measurement procedures. (H.K.)

  1. use of the RESRAD-BUILD code to calculate building surface contamination limits

    International Nuclear Information System (INIS)

    Faillace, E.R.; LePoire, D.; Yu, C.

    1996-01-01

    Surface contamination limits in buildings were calculated for 226 Ra, 230 Th, 232 Th, and natural uranium on the basis of 1 mSv y -1 (100 mrem y -1 ) dose limit. The RESRAD-BUILD computer code was used to calculate these limits for two scenarios: building occupancy and building renovation. RESRAD-BUILD is a pathway analysis model designed to evaluate the potential radiological dose incurred by individuals working or living inside a building contaminated with radioactive material. Six exposure pathways are considered in the RESRAD-BUILD code: (1) external exposure directly from the source; (2) external exposure from materials deposited on the floor; (3) external exposure due to air submersion; (4) inhalation of airborne radioactive particles; (5) inhalation of aerosol indoor radon progeny; and (6) inadvertent ingestion of radioactive material, either directly from the sources or from materials deposited on the surfaces. The code models point, line, area, and volume sources and calculates the effects of radiation shielding, building ventilation, and ingrowth of radioactive decay products. A sensitivity analysis was performed to determine how variations in input parameters would affect the surface contamination limits. In most cases considered, inhalation of airborne radioactive particles was the primary exposure pathway. However, the direct external exposure contribution from surfaces contaminated with 226 Ra was in some cases the dominant pathway for building occupancy depending on the room size, ventilation rates, and surface release fractions. The surface contamination limits are most restrictive for 232 Th, followed by 230 Th, natural uranium, and 226 Ra. The results are compared with the surface contamination limits in the Nuclear Regulatory Commission's Regulatory Guide 1.86, which are most restrictive for 226 Ra and 230 Th, followed by 232 Th, and are least restrictive for natural uranium

  2. Microbial contamination level of air in animal waste utilization plants.

    Science.gov (United States)

    Chmielowiec-Korzeniowska, Anna; Tymczyna, Leszek; Drabik, Agata; Krzosek, Łukasz

    2016-01-01

    The aim of this research was evaluation of microbial contamination of air within and in the vicinity of animal waste disposal plants. Air samples were analyzed to determine total bacterial and fungal counts as well as microbial species composition. Measurements of climate conditions (temperature, humidity, air motion) and total dust concentration were also performed. Total numbers of bacteria and fungi surpassed the threshold limit values for production halls. The most abundant bacteria detected were those consisting of physiological microflora of animal dermis and mucosa. Fungal species composition proved to be most differentiated in the air beyond the plant area. Aspergillus versicolor, a pathogenic and allergenic filamentous fungus, was isolated only inside the rendering plant processing hall. The measurement results showed a low sanitary-hygienic state of air in the plant processing halls and substantial air pollution in its immediate vicinity.

  3. What Orthopaedic Operating Room Surfaces Are Contaminated With Bioburden? A Study Using the ATP Bioluminescence Assay.

    Science.gov (United States)

    Richard, Raveesh Daniel; Bowen, Thomas R

    2017-07-01

    Contaminated operating room surfaces can increase the risk of orthopaedic infections, particularly after procedures in which hardware implantation and instrumentation are used. The question arises as to how surgeons can measure surface cleanliness to detect increased levels of bioburden. This study aims to highlight the utility of adenosine triphosphate (ATP) bioluminescence technology as a novel technique in detecting the degree of contamination within the sterile operating room environment. What orthopaedic operating room surfaces are contaminated with bioburden? When energy is required for cellular work, ATP breaks down into adenosine biphosphate (ADP) and phosphate (P) and in that process releases energy. This process is inherent to all living things and can be detected as light emission with the use of bioluminescence assays. On a given day, six different orthopaedic surgery operating rooms (two adult reconstruction, two trauma, two spine) were tested before surgery with an ATP bioluminescence assay kit. All of the cases were considered clean surgery without infection, and this included the previously performed cases in each sampled room. These rooms had been cleaned and prepped for surgery but the patients had not been physically brought into the room. A total of 13 different surfaces were sampled once in each room: the operating room (OR) preparation table (both pre- and postdraping), OR light handles, Bovie machine buttons, supply closet countertops, the inside of the Bair Hugger™ hose, Bair Hugger™ buttons, right side of the OR table headboard, tourniquet machine buttons, the Clark-socket attachment, and patient positioners used for total hip and spine positioning. The relative light units (RLUs) obtained from each sample were recorded and data were compiled and averaged for analysis. These values were compared with previously published ATP benchmark values of 250 to 500 RLUs to define cleanliness in both the hospital and restaurant industries. All

  4. Global occurrence of anti-infectives in contaminated surface waters: Impact of income inequality between countries.

    Science.gov (United States)

    Segura, Pedro A; Takada, Hideshige; Correa, José A; El Saadi, Karim; Koike, Tatsuya; Onwona-Agyeman, Siaw; Ofosu-Anim, John; Sabi, Edward Benjamin; Wasonga, Oliver V; Mghalu, Joseph M; dos Santos Junior, Antonio Manuel; Newman, Brent; Weerts, Steven; Yargeau, Viviane

    2015-07-01

    The presence anti-infectives in environmental waters is of interest because of their potential role in the dissemination of anti-infective resistance in bacteria and other harmful effects on non-target species such as algae and shellfish. Since no information on global trends regarding the contamination caused by these bioactive substances is yet available, we decided to investigate the impact of income inequality between countries on the occurrence of anti-infectives in surface waters. In order to perform such study, we gathered concentration values reported in the peer-reviewed literature between 1998 and 2014 and built a database. To fill the gap of knowledge on occurrence of anti-infectives in African countries, we also collected 61 surface water samples from Ghana, Kenya, Mozambique and South Africa, and measured concentrations of 19 anti-infectives. A mixed one-way analysis of covariance (ANCOVA) model, followed by Turkey-Kramer post hoc tests was used to identify potential differences in anti-infective occurrence between countries grouped by income level (high, upper-middle and lower-middle and low income) according to the classification by the World Bank. Comparison of occurrence of anti-infectives according to income level revealed that concentrations of these substances in contaminated surface waters were significantly higher in low and lower-middle income countries (p=0.0001) but not in upper-middle income countries (p=0.0515) compared to high-income countries. We explained these results as the consequence of the absence of or limited sewage treatment performed in lower income countries. Furthermore, comparison of concentrations of low cost anti-infectives (sulfonamides and trimethoprim) and the more expensive macrolides between income groups suggest that the cost of these substances may have an impact on their environmental occurrence in lower income countries. Since wastewaters are the most important source of contamination of anti-infectives and other

  5. Deuteriding of thin titanium films: the effect of carbon monoxide surface contamination

    International Nuclear Information System (INIS)

    Malinowski, M.W.

    1976-02-01

    The effect of adsorbed CO on the deuteriding of thin titanium films at room temperature was measured at D 2 pressures between 10 to 25 mtorr on films contaminated with CO exposures ranging between approximately 10 -8 torr-seconds (''clean'') to 10 -4 torr-seconds. In all measurements, for deuterium/titanium atom ratios greater than .2, the deuteriding appeared to be initally limited by the sticking of D 2 on the clean or contaminated titanium deuteride surface; the effective sticking coefficient on a clean titanium deuteride surface was approximately 3 x 10 -3 , while on a surface contaminated with 10 -4 torr-seconds of CO, the coefficient was reduced to approximately, 2 x 10 -4 . The pumping speeds of Ti films were dramatically different when the films were evaporated over TiD 2 . These changes were attributed to the presence of deuterium which diffused from the substrate film into the overlayer film

  6. Development of the automatic measuring system to survey the surface contamination on equipments

    International Nuclear Information System (INIS)

    Ishizuka, Akira; Matsumura, Hidekatsu; Nawa, Takao; Yamaguchi, Seiji; Yamada, Tadashi.

    1980-01-01

    The inspection of surface contamination carried out when things are taken out of the control areas in nuclear power stations requires considerable labor and time because it is carried out manually. In order to make the inspection of surface contamination more efficiently and to standardize it, the development of an automatic inspection apparatus was carried out. This apparatus inspects the surface contamination due to radio isotopes which do not emit α-ray, and the objects to be measured are the large things with definite forms, such as boards and pipes for scaffolding. The method of measuring β-ray with a gas flow counter was adopted for the apparatus in view of the good detection sensitivity, relatively simple shielding against background, and easy conversion to surface contamination density. The measuring system was composed of the gas flow counters and a rate meter. The outline of the apparatus made for trial is explained. As the result of the performance test, the lowest detection sensitivity was 1.29 x 10 -5 μCi/cm 2 at the moving speed of an object of 1 cm/sec. The detection sensitivity is improved by the flattening of the sensitivity distribution. The evaluation of the error, the reduction of measuring time and the prevention of contamination were also made. (Kako, I.)

  7. Surface sediment quality relative to port activities: A contaminant-spectrum assessment.

    Science.gov (United States)

    Yu, Shen; Hong, Bing; Ma, Jun; Chen, Yongshan; Xi, Xiuping; Gao, Jingbo; Hu, Xiuqin; Xu, Xiangrong; Sun, Yuxin

    2017-10-15

    Ports are facing increasing environmental concerns with their importance to the global economy. Numerous studies indicated sediment quality deterioration in ports; however, the deterioration is not discriminated for each port activity. This study investigated a spectrum of contaminants (metals and organic pollutants) in surface sediments at 20 sampling points in Port Ningbo, China, one of the top five world ports by volume. The spectrum of contaminants (metals and organic pollutants) was quantified following marine sediment quality guidelines of China and USA and surface sediment quality was assessed according to thresholds of the two guidelines. Coupling a categorical matrix of port activities with the matrix of sedimentary contaminants revealed that contaminants were highly associated with the port operations. Ship repair posed a severe chemical risk to sediment. Operations of crude oil and coal loadings were two top activities related to organic pollutants in sediments while port operations of ore and container loadings discharged metals. Among the 20 sampling points, Cu, Zn, Pb, and DDT and its metabolites were the priority contaminants influencing sediment quality. Overall, surface sediments in Port Ningbo had relatively low environmental risks but ship repair is an environmental concern that must be addressed. This study provides a practical approach for port activity-related quality assessment of surface sediments in ports that could be applicable in many world sites. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Lead contamination and transfer in urban environmental compartments analyzed by lead levels and isotopic compositions.

    Science.gov (United States)

    Hu, Xin; Sun, Yuanyuan; Ding, Zhuhong; Zhang, Yun; Wu, Jichun; Lian, Hongzhen; Wang, Tijian

    2014-04-01

    Lead levels and isotopic compositions in atmospheric particles (TSP and PM2.5), street dust and surface soil collected from Nanjing, a mega city in China, were analyzed to investigate the contamination and the transfer of lead in urban environmental compartments. The lead contents in TSP and PM2.5 are significantly higher than them in the surface soil and street dust (p lead to the major crustal elements (Al, Sr, Ti and Fe) indicates significant lead enrichment in atmospheric particles. The plots of (206)Pb/(207)Pb vs.(208)Pb/(206)Pb and (206)Pb/(207)Pb vs. 1/Pb imply that the street dust and atmospheric particles (TSP and PM2.5) have very similar lead sources. Coal emissions and smelting activities may be the important lead sources for street dust and atmospheric particles (TSP and PM2.5), while the deposition of airborne lead is an important lead source for urban surface soil. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. 40 CFR 141.66 - Maximum contaminant levels for radionuclides.

    Science.gov (United States)

    2010-07-01

    ... beta particle and photon radioactivity from man-made radionuclides in drinking water must not produce.../year). (2) Except for the radionuclides listed in table A, the concentration of man-made radionuclides... may make this technology too complex for small surface water systems. e Removal efficiencies can vary...

  10. Second IRMF comparison of surface contamination monitor calibrations 2001-2002

    CERN Document Server

    Scott, C J

    2002-01-01

    The Ionising Radiations Metrology Forum (IRMF) organised a second comparison of surface contamination monitor calibrations in which twenty establishments in the UK participated. The exercise involved the circulation of three surface contamination monitors for calibration using large area reference sources available in the participants' laboratories. The instruments used were a Mini Instruments EP15, a Berthold LB122 and an Electra ratemeter with DP6AD probe. The instrument responses were calculated by the individual participants and submitted to the for analysis along with details of the reference sources used. Details of the estimated uncertainties were also reported. The results are compared and demonstrate generally satisfactory agreement between the participating establishments.

  11. Effect of surface contaminants on the light emission spectrum of LiF TLDs

    International Nuclear Information System (INIS)

    Abhold, M.E.

    1987-01-01

    Recent results show the differences between the light emissions spectra from LiF Thermoluminescent Dosimeters (TLDs) for gamma vs. alpha irradiations to be due to contaminants on the surface of the TLD. The light emission spectrum for thermal neutron irradiations was observed to be identical to that for a Cs-137 gamma irradiation in Harshaw TLD-100. Further experiments with surface treatments on TLD-100 indicate trace contaminants introduced by the standard methanol cleansing rinse in reagent grade methanol to have a substantial effect on the light emission spectrum for Am-241 alpha irradiations

  12. Surface contamination effects on leaf chemical composition in the Atlantic Forest

    International Nuclear Information System (INIS)

    Ferrari, A.A.; Franca, E.J.; Fernandes, E.A.N.; Bacchi, M.A.

    2006-01-01

    The exogenous material that adheres to the leaf surface affects the elemental composition of the plant itself, thereby constituting one of the major error sources in plant analysis. The present work investigated the surface contamination of leaves from the Atlantic Forest. Instrumental neutron activation analysis (INAA) was applied to assess the efficiency of leaf EDTA-washing. Chemical element concentrations were corrected using Sc (soil tracer) since resuspended soil is the main source of contamination in leaves. As a result, EDTA-washing should be used mainly for the evaluation of terrigenous elements, while the Sc-corrected concentrations are considered satisfactory for the other elements. (author)

  13. Atmospheric-Pressure Plasma Cleaning of Contaminated Surfaces

    International Nuclear Information System (INIS)

    Hicks, Robert F.; Selwyn, Gary S.

    2001-01-01

    Project was to develop a low-cost, environmentally benign technology for the decontamination and decommissioning of transuranic waste. With the invention of the atmospheric-pressure plasma jet the goal was achieved. This device selectively etches heavy metals from surfaces, rendering objects radiation free and suitable for decommissioning. The volatile reaction products are captured on filters, which yields a tremendous reduction in the volume of the waste. Studies on tantalum, a surrogate material for plutonium, have shown that etch rate of 6.0 microns per minute can be achieved under mild conditions. Over the past three years, we have made numerous improvements in the design of the plasma jet. It may now be operated for hundreds of hours and not undergo any degradation in performance. Furthermore, small compact units have been developed, which are easily deployed in the field

  14. Force control of a robot for surface contamination detection

    International Nuclear Information System (INIS)

    Petterson, B.J.; Jones, J.F.

    1987-01-01

    A system is under development at Sandia National Laboratories for use in understanding the issues relating to automated robotic handling of spent nuclear fuel shipping casks. The goal of robotic handling is reduction of personnel radiation exposure at the proposed geologic repositories. One of the major technology development areas has been the integration of sensors into the control of the robot system to allow operation in semi-structured environments. In particular, a multiaxis force sensor is used to make robot trajectory corrections based on the contact force between the robot and workpiece. This force feedback system allows contact swipes (smears) to be made on the cask surface in a repeatable manner. 8 refs., 3 figs

  15. Atmospheric-Pressure Plasma Cleaning of Contaminated Surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Robert F. Hicks; Gary S. Selwyn

    2001-01-09

    Project was to develop a low-cost, environmentally benign technology for the decontamination and decommissioning of transuranic waste. With the invention of the atmospheric-pressure plasma jet the goal was achieved. This device selectively etches heavy metals from surfaces, rendering objects radiation free and suitable for decommissioning. The volatile reaction products are captured on filters, which yields a tremendous reduction in the volume of the waste. Studies on tantalum, a surrogate material for plutonium, have shown that etch rate of 6.0 microns per minute can be achieved under mild conditions. Over the past three years, we have made numerous improvements in the design of the plasma jet. It may now be operated for hundreds of hours and not undergo any degradation in performance. Furthermore, small compact units have been developed, which are easily deployed in the field.

  16. Secondary radioactive contamination of the Black Sea after Chernobyl accident: recent levels, pathways and trends.

    Science.gov (United States)

    Gulin, S B; Mirzoyeva, N Yu; Egorov, V N; Polikarpov, G G; Sidorov, I G; Proskurnin, V Yu

    2013-10-01

    The recent radionuclide measurements have showed that concentrations of the Chernobyl-derived (137)Cs and (90)Sr in the surface Black Sea waters are still relatively high, reaching 56 and 32 Bq m(-3), respectively. This is comparable or even exceeds the pre-Chernobyl levels (∼16 Bq (137)Cs and 22 Bq (90)Sr per m(3) as the basin-wide average values). The measurements have revealed that the Black Sea continues to receive Chernobyl radionuclides, particularly (90)Sr, by the runoff from the Dnieper River. An additional source of (90)Sr and (137)Cs was found in the area adjacent to the Kerch Strait that connects the Black Sea and the Sea of Azov. This may be caused by the inflow of the contaminated Dnieper waters, which come to this area through the North-Crimean Canal. The long-term monitoring of (137)Cs and (90)Sr concentration in the Black Sea surface waters and in the benthic brown seaweed Cystoseira sp., in comparison with the earlier published sediment records of the radionuclides, have showed signs of a secondary radioactive contamination, which has started to increase since the late 1990's. This may be the result of the combined effect of a higher input of radionuclides from the rivers in 1995-1999 due to an increased runoff; and a slow transport of the particulate bound radionuclides from the watersheds followed by their desorption in seawater from the riverine suspended matter and remobilization from the sediments adjacent to the river mouths. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Derived surface contamination limits for the uranium mining and milling industry

    International Nuclear Information System (INIS)

    Ching, S.H.

    1984-10-01

    Derived Surface Contamination Limits (DSCL) are proposed for the control of surface contamination at the work place for the uranium mining and milling industry. They have been derived by a method incorporating recent ICRP recommendations and consideration of the radiation exposure pathways of ingestion, inhalation and external irradiation of the basal layer of skin. A generalized DSCL of 10 5 Bq/m 2 of beta activity is recommended for all contaminants likely to be found in uranium mine and mill workplaces except for fresh uranium concentrates. In the latter case, the DSCL is expressed in terms of alpha activity because the ratio of beta to alpha activities for fresh uranium concentrates is variable; the beta activity increases with the ingrowth of U-238 daughter products (Th-234 and Pa-234m) until secular equilibrium is re-established in about six months. A surface contamination limit of 10 4 Bq/m 2 of beta activity is proposed for the release of non-porous materials and equipment with no detectable loose contamination to the public domain

  18. Concentration and toxicity of sea-surface contaminants in Puget Sound

    Energy Technology Data Exchange (ETDEWEB)

    Hardy, J.T.; Crecelius, E.A.; Kocan, R.

    1986-04-01

    The Marine Research Laboratory conducted studies during CY 1985 to evaluate the effects of sea-surface contamination on the reproductive success of a valued marine species. Microlayer and bulk water samples were collected from a rural bay, central Puget Sound, and three urban bays and analyzed for a number of metal and organic contaminants as well as for densities of neuston and plankton organisms. Fertilized neustonic eggs of sand sole (Psettichthys melanostictus) were exposed to the same microlayer samples during their first week of embryonic and larval development. Also, we evaluated the effects of microlayer extracts on the growth of trout cell cultures. Compared to rural sites, urban bays generally contained lower densities of neustonic flatfish eggs during the spawning season. Also, in contrast to the rural sites or the one central Puget Sound site, approximately half of the urban bay microlayer samples resulted in significant increases in embryo mortality (up to 100%), kyphosis (bent spine abnormalities) in hatched larvae, increased anaphase aberrations in developing embryos, and decreased trout cell growth. The toxic samples generally contained high concentrations of polycyclic aromatic and/or chlorinated hydrocarbons and/or potentially toxic metals. In some cases, concentrations of contaminants on the sea surface exceeded water-quality criteria by several orders of magnitude. Several samples of subsurface bulk water collected below highly contaminated surfaces showed no detectable contamination or toxicity.

  19. Optimization of the allowed levels of radioactive contamination on a virtual market of polluted provisions

    International Nuclear Information System (INIS)

    Frantsevich, L.Yi.

    1997-01-01

    The goal is to optimize the allowed levels of 137 Cs contamination of food products according to the ALARA principle. The model creates a virtual market of contaminated daily portions of various products, their contamination being distributed log normally with the same parameters as in real products. The consumer requests portions and wasters contaminated until one obtains 365 acceptable portions of every product per year. The cost of wastering is high at a low allowed level. The floating price of irradiation depends on the yearly consumption of 137 Cs and is stated very high when the last value approaches the dose limit (risk aversive function). Varying allowed levels, it is possible to minimize the cost of wastering and total cost of wastering and irradiation. The iterative algorithm is proposed

  20. ASSESSMENT OF RADIOACTIVE AND NON-RADIOACTIVE CONTAMINANTS FOUND IN LOW LEVEL RADIOACTIVE WASTE STREAMS

    International Nuclear Information System (INIS)

    R.H. Little, P.R. Maul, J.S.S. Penfoldag

    2003-01-01

    This paper describes and presents the findings from two studies undertaken for the European Commission to assess the long-term impact upon the environment and human health of non-radioactive contaminants found in various low level radioactive waste streams. The initial study investigated the application of safety assessment approaches developed for radioactive contaminants to the assessment of nonradioactive contaminants in low level radioactive waste. It demonstrated how disposal limits could be derived for a range of non-radioactive contaminants and generic disposal facilities. The follow-up study used the same approach but undertook more detailed, disposal system specific calculations, assessing the impacts of both the non-radioactive and radioactive contaminants. The calculations undertaken indicated that it is prudent to consider non-radioactive, as well as radioactive contaminants, when assessing the impacts of low level radioactive waste disposal. For some waste streams with relatively low concentrations of radionuclides, the potential post-closure disposal impacts from non-radioactive contaminants can be comparable with the potential radiological impacts. For such waste streams there is therefore an added incentive to explore options for recycling the materials involved wherever possible

  1. Experimental analysis on removal factor of smear method in measurement of surface contamination

    International Nuclear Information System (INIS)

    Sugiura, Nobuyuki; Taira, Junichi; Takenaka, Keisuke; Yamanaka, Kazuo; Sugai, Kenji; Kosako, Toshiso

    2007-01-01

    The smear test is one of the important ways to measure surface contamination. The loose contamination under the high background radiation, which is more significant in handling non-sealed radioisotopes, can be evaluated by this method. The removal factor is defined as the ratio of the activity removed from the surface by one smear to the whole activity of the removable surface contamination. The removal factor is greatly changed by the quality and condition of surface materials. In this study, the values of removal factor at several typical surface conditions were evaluated experimentally and the practical application of those values was considered. It is required the smear should be pressed by moderate pressure when wiping the surface. The pressure from 1.0 kg to 1.5 kg per filter paper was recommended. The removal factor showed lower value in wiping by the pressure below 1.0 kg. The value of 0.5 for the removal factor could be applied to the smooth surface of linoleum, concrete coated with paint or epoxy resin, stainless steel and glass with the statistical allowance. (author)

  2. Measurement of underground contamination of non-aqueous phase liquids (NAPLs) on the basis of the radon concentration in ground level air

    International Nuclear Information System (INIS)

    Schubert, M.

    2001-01-01

    It was investigated whether measurements of radon concentrations in ground level air are a suitable method of detecting sub-surface soil contamination with non-aqueous phase liquids (NAPLs). The working postulation was that, due to the very high solubility of radon in NAPLs, and the resulting accumulation of radon in NAPLs, radon exhalation to the ground level air in the proximity of such NAPL contamination should be locally reduced, thus indicating contamination of sub-surface soils with NAPLs. The research work reported was to verify the working theory by way of experiments, and to finally develop a reliable detection method for NAPL contaminations. The investigations comprised theoretical studies, laboratory experiments, experiments in defined soil columns, and extensive field studies [de

  3. Dosimetry of skin-contact exposure to tritium gas contaminated surfaces

    International Nuclear Information System (INIS)

    Legare, M.

    1990-12-01

    The radiological hazards from tritium are usually associated with exposure to tritium oxide either by inhalation, ingestion or permeation through skin. However, exposure from skin contact with tritium gas contaminated surfaces represents a different radiological hazard in tritium removal facilities and future fusion power plants. Previous experiments on humans and more recent experiments on hairless rats at Chalk River Laboratories have shown that when a tritium gas-contaminated surface is brought into contact with intact skin, high concentrations of organically-bound tritium in urine and skin are observed which were not seen from single tritiated water (liquid or vapour form) contamination. The results of the rat experiments, which involved measurements of tritium activity in urine and skin, after contact with contaminated stainless steel, are described. These results are also compared to previous data from human experiments. The effect of various exposure conditions and different contaminated surfaces such as brass, aluminum and glass are analysed and related to the results from contaminated stainless steel exposure. Dosimetric models are being developed in order to improve the basis for dose assessment for this mode of tritium uptake. The presently studied model is explained along with the assumptions and methods involved in its derivation. The features of 'STELLA', the software program used to implement the model, are discussed. The methods used to estimate skin and whole body dose from a model are demonstrated. Finally, some experiments for improving the accuracy of the model are proposed. Briefly, this study compares the results from animal and human experiments as well as different exposure conditions, and determines the range of whole body and skin dose that may be involved from skin-contact intake. This information is essential for regulatory purposes particularly in the derivation of doses for skin-contact contamination. (15 figs., 7 tabs., 29 refs.)

  4. Surface contamination of counting tools after mock dispensing of cyclophosphamide in a simulated outpatient pharmacy.

    Science.gov (United States)

    Chaffee, Bruce W; Lander, Michael J; Christen, Catherine; Redic, Kimberly A

    2018-01-01

    Purpose The primary aim was to determine if dispensing of cyclophosphamide tablets resulted in accumulated residue on pharmacy counting tools during a simulated outpatient dispensing process. Secondary objectives included determining if cyclophosphamide contamination exceeded a defined threshold level of 1 ng/cm 2 and if a larger number of prescriptions dispensed resulted in increased contamination. Methods Mock prescriptions of 40 cyclophosphamide 50 mg tablets were counted on clean trays in three scenarios using a simulated outpatient pharmacy after assaying five cleaned trays as controls. The three scenarios consisted of five simulated dispensings of one, three, or six prescriptions dispensed per scenario. Wipe samples of trays and spatulas were collected and assayed for all trays, including the five clean trays used as controls. Contamination was defined as an assayed cyclophosphamide level at or above 0.001 ng/cm 2 and levels above 1 ng/cm 2 were considered sufficient to cause risk of human uptake. Mean contamination for each scenario was calculated and compared using one-way analysis of variance. P-values of contamination on trays used to count one, three, and six cyclophosphamide prescriptions was 0.51 ± 0.10 (p=0.0003), 1.02 ± 0.10 (p contamination. Increasing the number of prescriptions dispensed from 1 to 3, 1 to 6, and 3 to 6 counts increased contamination by 0.51 ± 0.15 (p = 0.0140), 1.31 + 0.15 (p contaminates pharmacy counting tools, and an increased number of prescriptions dispensed correlates with increased level of contamination. Counting out three or more prescriptions leads to trays having contamination that surpasses the threshold at which worker exposure may be increased. Pharmacies should consider devoting a separate tray to cyclophosphamide tablets, as cross-contamination could occur with other drugs and the efficacy of decontamination methods is unclear. Employee exposure could be minimized with the use

  5. The influence of Triga 2000 reactor operation on the surface contamination at reactor room using smear test method

    International Nuclear Information System (INIS)

    Bintu Khoiriyyah; Budi Purnama; Tri Cahyo Laksono

    2016-01-01

    The monitoring of surface contamination should be conducted to determine the safety of work areas. Surface contamination at the TRIGA 2000 reactor room which is on PSTNT-BATAN Bandung remain to be implemented although reactor not operating. In this research monitoring of surface contamination when TRIGA 2000 in operation of the first time after several years not operating aims to determine the influence on the results of monitoring. The monitoring of surface contamination has been done using smear test method at some predetermined in TRIGA 2000 reactor room. The highest surface contamination activities is obtained 0.32 Bq/cm 2 and there are some points that are not detected. Based on keputusan kepala BAPETEN No.1/Ka BAPETEN/ V/99 the work showed that the TRIGA 2000 reactor in the category of low area contamination, that is <3.7 Bq/cm 2 to gross beta. (author)

  6. Contamination of environmental surfaces by methicillin-resistant Staphylococcus aureus (MRSA) in rooms of inpatients with MRSA-positive body sites.

    Science.gov (United States)

    Kurashige, E Jessica Ohashi; Oie, Shigeharu; Furukawa, H

    2016-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) can contaminate environmental surfaces that are frequently touched by the hands of patients with MRSA colonization/infection. There have been many studies in which the presence or absence of MRSA contamination was determined but no studies in which MRSA contamination levels were also evaluated in detail. We evaluated MRSA contamination of environmental surfaces (overbed tables, bed side rails, and curtains) in the rooms of inpatients from whom MRSA was isolated via clinical specimens. We examined the curtains within 7-14 days after they had been newly hung. The environmental surfaces were wiped using gauze (molded gauze for wiping of surface bacteria; 100% cotton, 4cm×8cm) moistened with sterile physiological saline. The MRSA contamination rate and mean counts (range) were 25.0% (6/24 samples) and 30.6 (0-255)colony-forming units (cfu)/100cm(2), respectively, for the overbed tables and 31.6% (6/19 samples) and 159.5 (0-1620)cfu/100cm(2), respectively, for the bed side rails. No MRSA was detected in 24 curtain samples. The rate of MRSA contamination of environmental surfaces was high for the overbed tables and bed side rails but low for the curtains. Therefore, at least until the 14th day of use, frequent disinfection of curtains may be not necessary. Copyright © 2016. Published by Elsevier Editora Ltda.

  7. Resistance of Pseudomonas aeruginosa to liquid disinfectants on contaminated surfaces before formation of biofilms.

    Science.gov (United States)

    Sagripanti, J L; Bonifacino, A

    2000-01-01

    A comparison was made of the effectiveness of popular disinfectants (Cavicide, Cidexplus, Clorox, Exspor, Lysol, Renalin, and Wavicide) under conditions prescribed for disinfection in the respective product labels on Pseudomonas aeruginosa either in suspension or deposited onto surfaces of metallic or polymeric plastic devices. The testing also included 7 nonformulated germicidal agents (glutaraldehyde, formaldehyde, peracetic acid, hydrogen peroxide, sodium hypochlorite, phenol, and cupric ascorbate) commonly used in disinfection and decontamination. Results showed that P. aeruginosa is on average 300-fold more resistant when present on contaminated surfaces than in suspension. This increase in resistance agrees with results reported in studies of biofilms, but unexpectedly, it precedes biofilm formation. The surface to which bacteria are attached can influence the effectiveness of disinfectants. Viable bacteria attached to devices may require dislodging through more than a one-step method for detection. The data, obtained with a sensitive and quantitative test, suggest that disinfectants are less effective on contaminated surfaces than generally acknowledged.

  8. Aluminum-contaminant transport by surface runoff and bypass flow from an acid sulphate soil

    NARCIS (Netherlands)

    Minh, L.Q.; Tuong, T.P.; Mensvoort, van M.E.F.; Bouma, J.

    2002-01-01

    Quantifying the process and the amount of acid-contaminant released to the surroundings is important in assessing the environmental hazards associated with reclaiming acid sulphate soils (ASS). The roles of surface runoff and bypass flow (i.e. the rapid downward flow of free water along macropores

  9. Bond strength of resin-resin interfaces contaminated with saliva and submitted to different surface treatments

    DEFF Research Database (Denmark)

    Furuse, Adilson Yoshio; da Cunha, Leonardo Fernandes; Benetti, Ana Raquel

    2007-01-01

    of silane and adhesive system. Resin cylinders were placed over the treated surfaces. The specimens were stored in water or ethanol. Shear bond strength tests were performed and the mode of failure was evaluated. Data were submitted to two-way ANOVA and Dunnett T3 test. Contamination of resin...

  10. A new technique for the identification of surface contamination in low temperature bolometric experiments

    International Nuclear Information System (INIS)

    Sangiorgio, S.; Arnaboldi, C.; Brofferio, C.; Bucci, C.; Capelli, S.; Carbone, L.; Clemenza, M.; Cremonesi, O.; Fiorini, E.; Foggetta, L.; Giuliani, A.; Gorla, P.; Nones, C.; Nucciotti, A.; Pavan, M.; Pedretti, M.; Pessina, G.; Pirro, S.; Previtali, E.; Salvioni, C.

    2011-01-01

    In the framework of the bolometric experiment CUORE, a new and promising technique has been developed in order to control the dangerous contamination coming from the surfaces close to the detector. In fact, by means of a composite bolometer, it is possible to partially overcome the loss of spatial resolution of the bolometer itself and to clearly identify events coming from outside.

  11. ASSESSMENTOF BETA PARTICLE FLUX FROM SURFACE CONTAMINATION AS A RELATIVE INDICATOR FOR RADIONUCLIDE DISTRIBUTION ON EXTERNAL SURFACES OF A MULTI-STORY BUILDING IN PRIPYAT

    Energy Technology Data Exchange (ETDEWEB)

    Farfan, E.

    2009-11-17

    How would we recover if a Radiological Dispersion Device (e.g., dirty bomb) or Improvised Nuclear Device were to detonate in a large city? In order to assess the feasibility of remediation following such an event, several issues would have to be considered, including the levels and characteristics of the radioactive contamination, the availability of the required resources to accomplish decontamination, and the planned future use of the city's structures and buildings. Presently little is known about the distribution, redistribution, and migration of radionuclides in an urban environment. However, Pripyat, a city substantially contaminated by the Chernobyl Nuclear Power Plant accident, may provide some answers. The main objective of this study was to determine the radionuclide distribution on a Pripyat multi-story building, which had not been previously decontaminated and therefore could reflect the initial fallout and its further natural redistribution on external surfaces. The 7-story building selected was surveyed from the ground floor to the roof on horizontal and vertical surfaces along seven ground-to-roof transections. Some of the results from this study indicate that the upper floors of the building had higher contamination levels than the lower floors. The authors consequently recommend that existing decontamination procedures for tall structures be re-examined and modified accordingly.

  12. Damage coefficient and defect level of copper-contaminated silicon N+P diode

    International Nuclear Information System (INIS)

    Usami, A.; Kato, Y.

    1975-01-01

    The damage coefficient at 298 0 K of copper-contaminated N + P diodes is smaller than that of non-contaminated ones. In these copper-contaminated samples, the higher the bulk resistivity is, the smaller is the damage coefficient. For non-contaminated diodes, the damage coefficient of samples of pulled bulk crystals is smaller than that of floating zone crystals, and the higher bulk resistivity diodes have smaller damage coefficient. At 217 0 K measurement, the effect of copper-contamination on the damage coefficient could not be observed. The energy levels of defects introduced by gamma ray irradiation are approximately0.30 eV, and approximately0.28 eV with non-contaminated FZ 135 ohm-cm and CZ 10 ohm-cm bulk samples, respectively. In copper-contaminated samples, approximately0.60 eV and approximately0.45 eV are obtained as the defect energy levels for FZ 135 ohm-cm and CZ 10 ohm-cm bulk samples. (U.S.)

  13. SCO shipments from Rocky Flats - Experience and current practice [Surface Contaminated Object

    International Nuclear Information System (INIS)

    Bracken, Gary; Morris, Robert L.

    2001-01-01

    Decommissioning activities at Rocky Flats Environmental Technology Site (RFETS) are expected to generate approximately 251,000 cubic meters of low-level radioactive waste. Almost half of this will be characterized and shipped as the Department of Transportation ''Surface Contaminated Object'' (SCO) shipping class. In the 2 years since an SCO characterization method was implemented, almost 11,000 of the 18,000 cubic meters of low-level waste were SCO. RFETS experience to-date using an SCO waste characterization method has shown significant time and cost savings, reduced errors, and enhanced employee safety. SCO waste is characterized prior to packaging, near the point of generation, by any of the site's 300 Radiological Control Technicians using inexpensive radiological control survey instruments. This reduces on-site waste container moves and eliminates radiometric analysis at centrally located drum or crate counters. Containers too large for crate counters can also be characterized. Current instrumentation is not adequate to take full advantage of the SCO regulations. Future improvements in the SCO characterization and shipping process are focused on use of larger and/or reusable containers, extended-range instruments, and additional statistical methods, so that the full extent of the SCO regulations can be used

  14. Assessment of the environmental radioactive contamination levels by depleted uranium after NATO aggression on FR Yugoslavia

    International Nuclear Information System (INIS)

    Pavlovic, S.; Pavlovic, R.; Markovic, S; Plecas, I.

    2001-01-01

    During NATO aggression on FR Yugoslavia various ammunition have been used, some of them for the first time. Among others, 30 mm bullets with depleted uranium (DU) penetrators have been used. Radioactivity contamination surveys have started during the war due to indications that DU is used in cruise missiles. Besides that, there were a lot of radioactivity analysis of food, drinking water etc. Some of the obtained results are presented in this paper. Depleted uranium ammunition can permanently contaminate environment and so produce effects on population. Relation of the international radiation and environmental protection standards and contamination levels are discussed as well. (author)

  15. Prevalence and contamination levels of listeria monocytogenes in ready-to-eat foods in Tokyo, Japan.

    Science.gov (United States)

    Shimojima, Yukako; Ida, Miki; Nakama, Akiko; Nishino, Yukari; Fukui, Rie; Kuroda, Sumiyo; Hirai, Akihiko; Kai, Akemi; Sadamasu, Kenji

    2016-08-01

    We surveyed prevalence and contamination levels of Listeria monocytogenes in ready-to-eat foods between 2000 and 2012 in Tokyo. L. monocytogenes was isolated from 52 (1.7%) out of 2,980 samples. Comparing the prevalence in the study period, 2.2% were positive in the former period (2000-2005) and 1.2% in the latter (2006-2012). Using the most probable number (MPN) technique, 32 samples were contaminated with fewer than 0.3 L. monocytogenes/g, 10 samples with 0.3-1.0/g and 4 samples with more than 1.0/g (the maximum was 2.3/g). The most common serovar was 1/2a, followed by 1/2b, 4b and 1/2c. We revealed that ready-to-eat foods in Tokyo were contaminated with L. monocytogenes, although the contamination levels were low.

  16. Actinide migration from contaminated soil to surface water at the rocky flats environmental technology site

    International Nuclear Information System (INIS)

    Santschi, Peter H.; Roberts, Kimberly

    2002-01-01

    Surficial soils of the Rocky Flats Environmental Technology Site (RFETS) contain elevated levels of 239,240 Pu and 241 Am due to wind dispersal of soil particles, contaminated in the 1960's by leaking drums stored on the 903 Pad. Over the past 4 years, actinide mobility in the surface environment at RFETS, Golden, Colorado, USA, was examined through field and laboratory experiments. From measurements of total 239,240 Pu and 241 Am concentrations in storm runoff and pond discharge samples, collected during spring and summer times, it was established that most of the actinide transport from contaminated soils to streams occurred in the particulate (0.45μm) and colloidal (3kDa - 0.45μm) phases. Controlled laboratory investigations of soil resuspension, indicated that remobilization of colloid-bound Pu during soil erosion events can be enhanced by humic acids. 2-D Polyacrylamide Gel electrophoresis (PAGE) experiments of radiolabeled colloidal organic and inorganic matter, extracted from RFETS soils, suggested that colloidal Pu, which was focused at pH IEP of 4.5, is mainly associated with organic (humic acids) colloids of 10-15 kDa molecular weight. Pu(IV) oxide and inorganic colloids such as iron and aluminum oxides have pH IEP of 8-10. While some clay minerals also have pH IEP of 3-5, no Al was found coincident with Pu. This finding has important ramifications for possible remediation, erosion controls, and land-management strategies. (author)

  17. TECHNICAL BASIS FOR EVALUATING SURFACE BARRIERS TO PROTECT GROUNDWATER FROM DEEP VADOSE ZONE CONTAMINATION

    International Nuclear Information System (INIS)

    Fayer, J.M.; Freedman, V.L.; Ward, A.L.; Chronister, G.B.

    2010-01-01

    The U.S. DOE and its predecessors released nearly 2 trillion liters (450 billion gallons) of contaminated liquid into the vadose zone at the Hanford Site. Some of the contaminants currently reside in the deeper parts of the vadose zone where they are much less accessible to characterization, monitoring, and typical remediation activities. The DOE Richland Operations Office (DOE-RL) prepared a treatability test plan in 2008 to examine remediation options for addressing contaminants in the deep vadose zone; one of the technologies identified was surface barriers (also known as engineered barriers, covers, and caps). In the typical configuration, the contaminants are located relatively close to the surface, generally within 15 m, and thus they are close to the base of the surface barrier. The proximity of the surface barrier under these conditions yielded few concerns about the effectiveness of the barrier at depth, particularly for cases in which the contaminants were in a lined facility. At Hanford, however, some unlined sites have contaminants located well below depths of 15 m. The issue raised about these sites is the degree of effectiveness of a surface barrier in isolating contaminants in the deep vadose zone. Previous studies by Hanford Site and PNNL researchers suggest that surface barriers have the potential to provide a significant degree of isolation of deep vadose zone contaminants. The studies show that the actual degree of isolation is site-specific and depends on many factors, including recharge rates, barrier size, depth of contaminants, geohydrologic properties ofthe sediments, and the geochemical interactions between the contaminants and the sediments. After the DOE-RL treatability test plan was published, Pacific Northwest National Laboratory was contracted to review the information available to support surface barrier evaluation for the deep vadose zone, identify gaps in the information and outcomes necessary to fill the data gaps, and outline

  18. Contamination monitoring of Na 131 I levels in therapy unit of Research Institute for Nuclear Medicine, Tehran University of Medical Sciences by indirect method (Wipe test)

    International Nuclear Information System (INIS)

    Beiki, D.; Shahhosseini, S.; Eftekhari, M.; Takavar, A.; Fard-Esfahani, A.

    2003-01-01

    Contamination with radiopharmaceuticals in nuclear medicine centres in addition to being a health concern requires time consuming decontamination efforts. According to Nuclear Regulatory Commission Contamination should be monitored in nuclear medicine centers where radiopharmaceuticals are prepared and administrated at the end of each working session; otherwise, contamination spread to other areas not only equipment but also personnel and other people will be expected. The wipe test for the presence of radioactivity is accomplished by wiping the surface over an area approximately 100 cm 2 with an absorbent paper, then counting it in an appropriate radiation detector. In this study, contamination monitoring of patient's rooms (4 rooms), entrance corridor, patient's corridor, waiting room, control room (nursing station), radiopharmaceutical storage room in therapy unit of Research Institute for Nuclear Medicine, Shariati hospital was performed by indirect method. Based on the results, some areas including storage room were contaminated. There was also a direct relationship between dose administrated and levels of contamination in patient's rooms. Regarding high uptake of iodine by thyroid gland and damaging effects of Na 131 I, weekly wipe tests are required to determine the level of contamination. Patient's rooms after discharging the patients and before re hospitalization specially should be checked. If these tests reveal contamination over standard levels, appropriate decontamination procedures should be carried out immediately

  19. A new cleaning process for the metallic contaminants on a post-CMP wafer's surface

    International Nuclear Information System (INIS)

    Gao Baohong; Liu Yuling; Wang Chenwei; Wang Shengli; Zhou Qiang; Tan Baimei; Zhu Yadong

    2010-01-01

    This paper presents a new cleaning process using boron-doped diamond (BDD) film anode electrochemical oxidation for metallic contaminants on polished silicon wafer surfaces. The BDD film anode electrochemical oxidation can efficiently prepare pyrophosphate peroxide, pyrophosphate peroxide can oxidize organic contaminants, and pyrophosphate peroxide is deoxidized into pyrophosphate. Pyrophosphate, a good complexing agent, can form a metal complex, which is a structure consisting of a copper ion, bonded to a surrounding array of two pyrophosphate anions. Three polished wafers were immersed in the 0.01 mol/L CuSO 4 solution for 2 h in order to make comparative experiments. The first one was cleaned by pyrophosphate peroxide, the second by RCA (Radio Corporation of America) cleaning, and the third by deionized (DI) water. The XPS measurement result shows that the metallic contaminants on wafers cleaned by the RCA method and by pyrophosphate peroxide is less than the XPS detection limits of 1 ppm. And the wafer's surface cleaned by pyrophosphate peroxide is more efficient in removing organic carbon residues than RCA cleaning. Therefore, BDD film anode electrochemical oxidation can be used for microelectronics cleaning, and it can effectively remove organic contaminants and metallic contaminants in one step. It also achieves energy saving and environmental protection. (semiconductor technology)

  20. Methodology for determining acceptable residual radioactive contamination levels at decommissioned nuclear facilities/sites

    International Nuclear Information System (INIS)

    Watson, E.C.; Kennedy, W.E. Jr.; Hoenes, G.R.; Waite, D.A.

    1979-01-01

    The ultimate disposition of decommissioned nuclear facilities and their surrrounding sites depends upon the degree and type of residual contamination. Examination of existing guidelines and regulations has led to the conclusion that there is a need for a general method to derive residual radioactive contamination levels that are acceptable for public use of any decommissioned nuclear facility or site. This paper describes a methodology for determining acceptable residual radioactive contamination levels based on the concept of limiting the annual dose to members of the public. It is not the purpose of this paper to recommend or even propose dose limits for the exposure of the public to residual radioactive contamination left at decommissioned nuclear facilities or sites. Unrestricted release of facilities and/or land is based on the premise that the potential annual dose to any member of the public using this property from all possible exposure pathways will not exceed appropriate limits as may be defined by Federal regulatory agencies. For decommissioned land areas, consideration should be given to people living directly on previously contaminated areas, growing crops, grazing food animals and using well water. Mixtures of radionuclides in the residual contamination representative of fuel reprocessing plants, light water reactors and their respective sites are presented. These mixtures are then used to demonstrate the methodology. Example acceptable residual radioactive contamination levels, based on an assumed maximum annual dose of one millirem, are calculated for several selected times following shutdown of a facility. It is concluded that the methodology presented in this paper results in defensible acceptable residual contamination levels that are directly relatable to risk assessment with the proviso that an acceptable limit to the maximum annual dose will be established. (author)

  1. GWSCREEN: A semi-analytical model for assessment of the groundwater pathway from surface or buried contamination: Theory and user's manual

    International Nuclear Information System (INIS)

    Rood, A.S.

    1992-03-01

    GWSCREEN was developed for assessment of the groundwater pathway from leaching of radioactive and non radioactive substances from surface or buried sources. The code was designed for implementation in the Track 1 and Track 2 assessment of Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) sites identified as low probability hazard at the Idaho National Engineering Laboratory (DOE, 1991). The code calculates the limiting soil concentration such that regulatory contaminant levels in groundwater are not exceeded. The code uses a mass conservation approach to model three processes: Contaminant release from a source volume, contaminant transport in the unsaturated zone, and contaminant transport in the saturated zone. The source model considers the sorptive properties and solubility of the contaminant. Transport in the unsaturated zone is described by a plug flow model. Transport in the saturated zone is calculated with a semi-analytical solution to the advection dispersion equation for transient mass flux input

  2. GWSCREEN: A semi-analytical model for assessment of the groundwater pathway from surface or buried contamination: Theory and user's manual

    Energy Technology Data Exchange (ETDEWEB)

    Rood, A.S.

    1992-03-01

    GWSCREEN was developed for assessment of the groundwater pathway from leaching of radioactive and non radioactive substances from surface or buried sources. The code was designed for implementation in the Track 1 and Track 2 assessment of Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) sites identified as low probability hazard at the Idaho National Engineering Laboratory (DOE, 1991). The code calculates the limiting soil concentration such that regulatory contaminant levels in groundwater are not exceeded. The code uses a mass conservation approach to model three processes: Contaminant release from a source volume, contaminant transport in the unsaturated zone, and contaminant transport in the saturated zone. The source model considers the sorptive properties and solubility of the contaminant. Transport in the unsaturated zone is described by a plug flow model. Transport in the saturated zone is calculated with a semi-analytical solution to the advection dispersion equation for transient mass flux input.

  3. GWSCREEN: A semi-analytical model for assessment of the groundwater pathway from surface or buried contamination: Theory and user`s manual

    Energy Technology Data Exchange (ETDEWEB)

    Rood, A.S.

    1992-03-01

    GWSCREEN was developed for assessment of the groundwater pathway from leaching of radioactive and non radioactive substances from surface or buried sources. The code was designed for implementation in the Track 1 and Track 2 assessment of Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) sites identified as low probability hazard at the Idaho National Engineering Laboratory (DOE, 1991). The code calculates the limiting soil concentration such that regulatory contaminant levels in groundwater are not exceeded. The code uses a mass conservation approach to model three processes: Contaminant release from a source volume, contaminant transport in the unsaturated zone, and contaminant transport in the saturated zone. The source model considers the sorptive properties and solubility of the contaminant. Transport in the unsaturated zone is described by a plug flow model. Transport in the saturated zone is calculated with a semi-analytical solution to the advection dispersion equation for transient mass flux input.

  4. Fermi level on hydrogen terminated diamond surfaces

    Czech Academy of Sciences Publication Activity Database

    Rezek, Bohuslav; Saurer, C.; Nebel, C. E.; Stutzmann, M.; Ristein, J.; Ley, L.; Snidero, E.; Bergonzo, P.

    2003-01-01

    Roč. 82, č. 14 (2003), s. 2266-2268 ISSN 0003-6951 EU Projects: European Commission(XE) HPRN-CT-1999-00139 Grant - others:DFC(DE) NE524-2 Institutional research plan: CEZ:AV0Z1010914 Keywords : atomic force microscope (AFM) * Kelvin probe experiments * diamond surface Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 4.049, year: 2003

  5. Evaluation of indigenously developed plastic scintillator sheet detector for surface radioactive contamination monitoring application

    International Nuclear Information System (INIS)

    Sahani, R.M.; Chaudhary, H.S.; Mahala, V.K.; Senwar, K.R.; Meena, J.P.

    2018-01-01

    Radioactive contamination may be caused by release of radioactivity in the environment due to accident at nuclear plant/reactor or spillage of loose radioactive materials in a laboratory. The protection of workers from potentially hazardous radiations emitted by the contaminants is a matter of prime concern. The detection of such radiations requires a monitoring system capable of measuring the level of radioactivity at the contaminated site. Plastic scintillators are widely used for large area radiation monitoring due to the ease of preparation in different shape and sizes. These detectors are sensitive to beta and gamma radiation therefore can be used for monitoring of beta and gamma contamination. In this paper, performance results of indigenously developed plastic scintillator sheet of area 800 cm 2 are reported

  6. Use of a surface contamination survey simulation program and its effects

    International Nuclear Information System (INIS)

    Onuma, Isamu; Kobayashi, Makoto; Umehara, Takashi; Shimizu, Isamu

    2012-01-01

    A computer simulation program has been developed to train the practitioners examining the surface contamination of objects to be carried out from the controlled area. The efficiency of the examination depends significantly on the proficiency in radiation measurement and proper perception of contamination. It has been demonstrated through the usage of the program that it helps practitioners very much suggest their weakness and promote their skill in examination. The program runs on the commonly used personal computers and users can easily experience the virtual examination by sweeping and cricking the mouse. The program is useful to radiation protection practitioners not only beginners but also experts. (author)

  7. Heavy metal contamination in surface runoff sediments of the urban area of Vilnius, Lithuania

    Directory of Open Access Journals (Sweden)

    Gytautas Ignatavičius

    2017-02-01

    Full Text Available Surface runoff from urbanized territories carries a wide range of pollutants. Sediments in untreated runoff from direct discharge stormwater systems significantly contribute to urban waterway pollution. In this study, heavy metal (Pb, Zn, Cu, Cr, Ba, As and Fe contamination in surface runoff sediments of the urban area of the city of Vilnius was investigated. The surface runoff sediment samples were collected from seven dischargers with the highest volume rate of water flow and concentrations of suspended solids. The geospatial analysis of the distribution of heavy metals shows that there are several active pollution sources supplying the dischargers with contaminated sediments. Most of these areas are located in the central part of the city and in old town with intense traffic. Principal components analysis and t-test results clearly depicted the significantly different chemical compositions of winter and autumn surface sediment samples. The sampling approach and assessment of results provide a useful tool to examine the contamination that is generated in urban areas, distinguish pollution sources and give a better understanding of the importance of permeable surfaces and green areas.

  8. Indoor and Outdoor Surface-Growing Fungi Contamination at Higher Institutional Buildings in a Malaysian University

    Science.gov (United States)

    Er, C. M.; Sunar, N. M.; Leman, A. M.; Khalid, A.; Ali, R.; Zaidi, E.; Azhar, A. T. S.

    2018-04-01

    Surface-growing indoor and outdoor fungi were assessed using swabbing method to investigate the indoor contamination. The painted wall surface samples were collected from two institutional buildings (B1 and B2) of a university in southern Peninsular Malaysia; indoors and outdoors. The mould concentrations varied widely between indoor and outdoor surface samples of both buildings. The total indoor surface-growing mould concentration (8776.49 CFU/cm2) is significantly higher (pair quality parameters (relative humidity, temperature and air velocity) were also measured indoors and outdoors during the study and violation of the guideline provided by ICOP-IAQ 2010 were proven in indoor environment in both buildings. The results of this assessment showed that the indoor environments of both institutional buildings were contaminated by the surface-growing mould. It also suggested the faulty designs and/or usages of building material in these institutional buildings contributed toward the contamination. An innovative solution is needed to correct the problems.

  9. Removal of copper and nickel contaminants from Si surface by use of cyanide solutions

    International Nuclear Information System (INIS)

    Fujiwara, N.; Liu, Y.-L.; Nakamura, T.; Maida, O.; Takahashi, M.; Kobayashi, H.

    2004-01-01

    The cleaning method using cyanide solutions has been developed to remove heavy metals such as copper (Cu) and nickel (Ni) from Si surfaces. Immersion of Si wafers with both Cu and Ni contaminants in potassium cyanide (KCN) solutions of methanol at room temperature decreases these surface concentrations below the detection limit of total reflection X-ray fluorescence spectroscopy of ∼3x10 9 atoms/cm 2 . UV spectra of the KCN solutions after cleaning of the Cu-contaminated Si surface show that stable copper-cyanide complexes are formed in the solution, leading to the prevention of the re-adsorption of copper in the solutions. From the complex stability constants, it is concluded that the Cu(CN) 4 3- is the most dominant species in the KCN solutions

  10. Contribution to Surface Water Contamination Understanding by Pesticides and Pharmaceuticals, at a Watershed Scale

    Directory of Open Access Journals (Sweden)

    Stéphanie Piel

    2012-12-01

    Full Text Available This study aims at understanding the presence of regulated and emerging micropollutants, particularly pesticides and pharmaceuticals, in surface water, regarding spatial and temporal influences at a watershed scale. The study of relations between micropollutants and other water quality and hydroclimatic parameters was carried out from a statistical analysis on historical and experimental data of different sampling sites from the main watershed of Brittany, western France. The outcomes point out the influence of urban and rural areas of the watershed as well as the impact of seasons on contamination variations. This work contributes to health risk assessment related to surface water contamination by micropollutants. This approach is particularly interesting in the case of agricultural watersheds such as the one studied, where more than 80% of surface water is used to produce drinking water.

  11. Laser cleaning of the contaminations on the surface of tire mould

    Science.gov (United States)

    Ye, Yayun; Jia, Baoshen; Chen, Jing; Jiang, Yilan; Tang, Hongping; Wang, Haijun; Luan, Xiaoyu; Liao, Wei; Zhang, Chuanchao; Yao, Caizhen

    2017-07-01

    During the manufacturing of tires, surface pollutants on tire mould will lead to the production of unqualified tires. Tire moulds need to be regularly cleaned. Laser cleaning is recognized as a non-destructive, effective, precise and environmental friendly method. In this paper, laser cleaning was used to remove contaminants on tire mould surface. First, laser induced damage experiments were performed. The results showed that the roughness and hardness of the cast steel sample surface seldom changed under the energy range of 140.1-580.2 mJ laser irradiation 1 pulse and the energy range of 44.7-168.9 mJ laser irradiation 100 pulses. In the laser cleaning experiments, the cleaning thresholds and the optimal cleaning parameters were obtained. Results indicated that laser cleaning was safe and effective for tire mould contamination removal.

  12. PROCEEDINGS WITH CONTAMINATED INDUSTRIAL SITES IN TERMS OF NEW LEGISLATION – PART I. HISTORICAL POLLUTION OF THE EARTH'S SURFACE

    OpenAIRE

    Magdalena Paulina Wiśniewska; Agnieszka Pusz

    2017-01-01

    This article shows a way of dealing with the industrial areas, where historical contamination of the earth’s surface occurred, together with an indication of the proper remediation method selection. Public Administration authorities, including the Regional Director of Environmental Protection (RDOŚ) and the governor are responsible, among others, for identifying areas where historical contamination or potential historical contamination of the earth's surface occurred. General Director of Envi...

  13. Correlation of BTEX levels and toxicity of condensate contaminated groundwater

    International Nuclear Information System (INIS)

    Headley, J.; Goudey, S.; Birkholz, D.; Hardisty, P.

    1995-01-01

    The concentration of BTEX was determined for 60 groundwater samples collected from 6 gas plants in Western Canada, using conventional purge-and-trap GC/MS procedures. The gas plants were selected to cover different types of operations with different amine process chemicals employed for the sweetening of the raw sour-gas condensates. Aliquots of the ground water samples were subjected to toxicity screening tests, specifically, (a) bacterial luminescence (microtox); (b) daphnia mortality and (c) fathead minnow mortality. For the toxicity tests, sample handling procedures were developed to minimize the loss of volatile organics during the experiments. To account for possible losses, the levels of BTEX were monitored at the start and upon completion of these tests. The results indicated that the toxicity of the groundwater was in general, well correlated to the concentration of BTEX (primarily xylene). Approximately 5% of the samples, however, were observed to be toxic although the concentration of BTEX were below the method detection limit (1 microg/1). Thiophenic volatile organics were implicated for the latter. Based on the laboratory results, the remediation of BTEX is expected to correlate with the removal of the toxicity of the groundwater. These findings are of direct relevance to present technologies employed for remediation of ground water at the Sourgas plants

  14. Mapping the environmental risk potential on surface water of pesticide contamination in the Prosecco's vineyard terraced landscape

    Science.gov (United States)

    Pizarro, Patricia; Ferrarese, Francesco; Loddo, Donato; Eugenio Pappalardo, Salvatore; Varotto, Mauro

    2016-04-01

    Intensive cropping systems today represent a paramount issue in terms of environmental impacts, since agricultural pollutants can constitute a potential threat to surface water, non-target organisms and aquatic ecosystems. Levels of pesticide concentrations in surface waters are indeed unquestionably correlated to crop and soil management practices at field-scale. Due to the numerous applications of pesticides required, orchards and vineyards can represent relevant non-point sources for pesticide contamination of water bodies, mainly prompted by soil erosion, surface runoff and spray drift. To reduce risks of pesticide contamination of surface water, the Directive 2009/128/CET imposed the local implementation of agricultural good practices and mitigation actions such as the use of vegetative buffer filter strips and hedgerows along river and pond banks. However, implementation of mitigation actions is often difficult, especially in extremely fragmented agricultural landscapes characterized by a complex territorial matrix set up on urban sprawling, frequent surface water bodies, important geomorphological processes and protected natural areas. Typically, such landscape matrix is well represented by the, Prosecco-DOCG vineyards area (NE of Italy, Province of Treviso) which lays on hogback hills of conglomerate, marls and sandstone that ranges between 50 and 500 m asl. Moreover such vineyards landscape is characterized by traditional and non-traditional agricultural terraces The general aim of this paper is to identify areas of surface water bodies with high potential risk of pesticide contamination from surrounding vineyards in the 735 ha of Lierza river basin (Refrontolo, TV), one of the most representative terraced landscape of the Prosecco-DOCG area. Specific aims are i) mapping terraced Prosecco-DOCG vineyards, ii) classifying potential risk from pesticide of the different areas. Remote sensing technologies such as four bands aerial photos (RGB+NIR) and Light

  15. Removal and treatment of radioactive, organochlorine, and heavy metal contaminants from solid surfaces

    International Nuclear Information System (INIS)

    Grieco, S.A.; Neubauer, E.D.

    1996-01-01

    The U.S. Department of Energy (DOE) is defining decontamination and decommissioning (D ampersand D) obligations at its sites. Current D ampersand D activities are generally labor intensive, use chemical reagents that are difficult to treat, and may expose workers to radioactive and hazardous chemicals. Therefore, new technologies are desired that minimize waste, allow much of the decommissioned materials to be reused rather than disposed of as waste, and produce wastes that will meet disposal criteria. The O'Brien ampersand Gere companies tested a scouring decontamination system on concrete and steel surfaces contaminated with radioactive and hazardous wastes under the sponsorship of Martin Marietta Energy Systems, Inc. (MMES) at DOE's K-25 former gaseous diffusion plant in Oak Ridge, Tennessee. The scouring system removes fixed radioactive and hazardous contamination yet leaves the surface intact. Blasting residuals are treated using physical/chemical processes. Bench- and pilot-scale testing of the system was conducted on surfaces contaminated with uranium, technetium, heavy metals, and PCBs. Areas of concrete and metal surfaces were blasted. Residuals were dissolved in tap water and treated for radioactive, hazardous, and organochlorine constituents. The treatment system comprised pH adjustment, aeration, solids settling, filtration, carbon adsorption, and ion exchange. This system produced treated water and residual solid waste. Testing demonstrated that the system is capable of removing greater than 95% of radioactive and PCB surface contamination to below DOE's unrestricted use release limits; aqueous radionuclides, heavy metals, and PCBs were below DOE and USEPA treatment objectives after treatment. Waste residuals volume was decreased by 71 %. Preliminary analyses suggest that this system provides significant waste volume reduction and is more economical than alternative surface decontamination techniques that are commercially available or under development

  16. Radioactive contamination of some rubber or plastic surfaces by fission products. Decontamination tests; Contamination radioactive de quelques surfaces en caoutchouc ou en matiere plastique par des produits de fission. Essais de decontamination

    Energy Technology Data Exchange (ETDEWEB)

    Mestre, E.; Sautiez, N.

    1957-10-15

    With the objective of notably addressing the contamination and decontamination of gloves and floor covering, this report first presents some characteristics of contaminating radioactive materials (nature, physical and chemical condition), of contaminated surfaces (surface condition, surface nature), and of decontamination processes (physical, chemical or mechanical action). It describes the operational modality implemented to test decontamination processes on various glove or flooring materials: sample preparation, counting, decontamination, reproducibility of decontamination tests, results in terms of activity reduction. It more precisely describes the tested samples: short gloves, gloves from glove boxes, floor and wall coverings. Results are presented and discussed in terms of sample susceptibility to contamination, and of decontamination, but also for re-contamination tests after a Nab-based decontamination (susceptibility to contamination, decontamination gain)

  17. Allowable residual contamination levels of radionuclides in soil from pathway analysis

    International Nuclear Information System (INIS)

    Nyquist, J.E.; Baes, C.F. III

    1987-01-01

    The Remedial Action Program (RAP) at Oak Ridge National Laboratory will include well drilling, facility upgrades, and other waste management operations likely to involve soils contaminated with radionuclides. A preliminary protocol and generalized criteria for handling contaminated soils is needed to coordinate and plan RAP activities, but there exists only limited information on contaminate nature and distribution at ORNL RAP sites. Furthermore, projections of long-term decommissioning and closure options for these sites are preliminary. They have adapted a pathway analysis model, DECOM, to quantify risks to human health from radionuclides in soil and used it to outline preliminary criteria for determining the fate of contaminated soil produced during RAP activities. They assumed that the site could be available for unrestricted use immediately upon decontamination. The pathways considered are consumption of food grown on the contaminated soil, including direct ingestion of soil from poorly washed vegetables, direct radiation from the ground surface, inhalation of resuspended radioactive soil, and drinking water from a well drilled through or near the contaminated soil. We will discuss the assumptions and simplifications implicit in DECOM, the site-specific data required, and the results of initial calculations for the Oak Ridge Reservation

  18. Effects of Land Use Types on the Levels of Microbial Contamination ...

    African Journals Online (AJOL)

    The effects of land use types on levels of microbial contamination based on total coliforms and E. coli (faecal coliform) levels was investigated in the Mara River system, Kenya and Tanzania. Water samples were taken from five sampling sites with different land uses and the Most Probable Number (MPN) method used to ...

  19. Quantification of mold contamination in multi-level buildings using the Environmental Relative Moldiness Index

    Science.gov (United States)

    The goal of this study was to evaluate the possible use of the Environmental Relative Moldiness Index (ERMI) to quantify mold contamination in multi-level, office buildings. Settled-dust samples were collected in multi-level, office buildings and the ERMI value for each sample de...

  20. Decontamination of plutonium-contaminated surfaces; Essais de decontamination des surfaces contaminees par du plutonium

    Energy Technology Data Exchange (ETDEWEB)

    Bertrand, J; Clouet d' Orval, Ch; Tachon, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The measure of the neutron distribution in the core of 'Proserpine', by means of activation detectors, requires no contact between the plutonium sulfate solution and the detectors. These detectors are put into PVC or polyethylene bags. This report describes the process used to decontaminate these bags. A washing by nitric acid followed by coating with plexiglass is kept, with this process we have no contamination on the detectors. (author) [French] La mesure de la distribution de neutrons par detecteurs a activation dans le coeur de Proserpine exige de proteger ces detecteurs contre tout contact avec la solution de plutonium. Les detecteurs sont places dans des gaines en polyvinyle ou en polyethylene. Ce rapport decrit le procede utilise pour decontaminer ces gaines. On a retenu un lavage a l'acide nitrique suivi du revetement d'une meme couche de plexiglass, ce qui permet d'eviter la contamination des detecteurs. (auteur)

  1. The level of Escherichia coli contamination in foods and drinks sold at canteens campus

    Directory of Open Access Journals (Sweden)

    Dewi Susanna

    2011-02-01

    Full Text Available Background: Bacterial contamination is a common phenomenon in foods served in campus canteens and my cause physical illness which will affect academic activity. The aim of this study was to rank the level of Escherichia coli contamination in food and drink in campus canteens.Methods: Forty nine (49 foods and 24 types of drink were examined using conventional agar broth method for calculation of most probable number (MPN. The steps of the mothod were presumptive test for coliforms, fecal coliforms and E. coli, confirmes test for coliforms, fecal coli and E. coli and then completed test for E. coli. An analysis for contamination by E. coli in meals, utensils, and on the hands of the server was also undertaken. The data analyzed in percentage and rank all type of foods and drinks, also rank based on the location.Results: Almost all type of meals was contaminated. Meals with chili sauce were the most risky from the contamination of E. coli (90.15 %, then followed by dry meals (38.89%, while the wet meals were the the most unrisky meals. In  drinks, the highest was lacy juice, followed by jambu (guava juice, then Sirsak and Orange juices on the third rank, while the mango juice was the lowest contamination. Melon juice, cappucino and fruit-coctail did not have E. coli  contamination.Conclusion: The contamination in the top three rank of contamination could be from the utensils used and foodhandler. (Med J Indones 2011; 20:66-70Keywords: campus, canteen, drink, Escherichia coli, food

  2. Microbial air quality and bacterial surface contamination in ambulances during patient services.

    Science.gov (United States)

    Luksamijarulkul, Pipat; Pipitsangjan, Sirikun

    2015-03-01

    We sought to assess microbial air quality and bacterial surface contamination on medical instruments and the surrounding areas among 30 ambulance runs during service. We performed a cross-sectional study of 106 air samples collected from 30 ambulances before patient services and 212 air samples collected during patient services to assess the bacterial and fungal counts at the two time points. Additionally, 226 surface swab samples were collected from medical instrument surfaces and the surrounding areas before and after ambulance runs. Groups or genus of isolated bacteria and fungi were preliminarily identified by Gram's stain and lactophenol cotton blue. Data were analyzed using descriptive statistics, t-test, and Pearson's correlation coefficient with a p-value of less than 0.050 considered significant. The mean and standard deviation of bacterial and fungal counts at the start of ambulance runs were 318±485cfu/m(3) and 522±581cfu/m(3), respectively. Bacterial counts during patient services were 468±607cfu/m(3) and fungal counts were 656±612cfu/m(3). Mean bacterial and fungal counts during patient services were significantly higher than those at the start of ambulance runs, p=0.005 and p=0.030, respectively. For surface contamination, the overall bacterial counts before and after patient services were 0.8±0.7cfu/cm(2) and 1.3±1.1cfu/cm(2), respectively (pair samples and bacterial counts on medical instruments and allocated areas. This study revealed high microbial contamination (bacterial and fungal) in ambulance air during services and higher bacterial contamination on medical instrument surfaces and allocated areas after ambulance services compared to the start of ambulance runs. Additionally, bacterial and fungal counts in ambulance air showed a significantly positive correlation with the bacterial surface contamination on medical instruments and allocated areas. Further studies should be conducted to determine the optimal intervention to reduce

  3. Cuban-Brazilian comparison of the calibration procedures for surface contamination monitors

    International Nuclear Information System (INIS)

    Salas, Gonzalo W.; Garcia, Jose A.T.; Ramos, Manoel M.O.

    2007-01-01

    The calibration laboratory of the CPHR, Centro de Proteccion e Higiene de las Radiaciones, is the only laboratory that performs calibrations of radiation protection instruments in Cuba. Recently they started a cooperation project with IAEA, code number CUB3002-01 with the task title 'Assuring and Demonstrating the safety of radioactive Waste Management'. Within the frame of this project they have a compromise to implement the calibration service for surface contamination monitors, for which they received instruments and sources. In 2006 the Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI) from the Instituto de Radioprotecao e Dosimetria, IRD/CNEN, was invited to perform a mission to CPHR in order to evaluate the level of implementation of the service trough the insertion of the service in the Quality Assurance System of their laboratory, and perform a comparison exercise to test the calibration method implemented. The results were evaluated by the methodology recommended in the ISO/IEC 43-1 standard. These results show that all values from both laboratories are comparable for most radionuclides except for Cl-36. The preliminary investigation about this situation is presented in the paper. (author)

  4. Contamination assessment of heavy metal in surface sediments of the Wuding River, northern China

    International Nuclear Information System (INIS)

    Longjiang, M.; Qiang, F.; Duowen, M.; Ke, H.; Jinghong, Y.

    2011-01-01

    The heavy metal contents and the contamination levels of the surface sediments of the Wuding River, northern China, were investigated. Heavy metal concentration ranged in μg g -1 : 50.15 - 71.91 for Cr, 408.1 - 442.9 for Mn, 20.11 - 43.59 for Ni, 17.51 - 20.1 for Cu, 68.32 - 89.57 for Zn, 0.2 - 0.38 for Cd and 15.08 - 16.14 for Pb in the Wuding River sediments. The enrichment factor (EF) and the geo-accumulation index (Igeo) demonstrated that the sediments of the Wuding River had been polluted by Cd, Cr and Ni, which mainly originated from anthropogenic sources, whereas the sediments had not been polluted by Zn, Pb, Cu and Mn, which were derived from the crust. In addition, the assessment results of EF and Igeo suggested that the sediments of the Wuding River was 'moderately' polluted by Cd and 'unpolluted to moderately' polluted by Cr and Ni. The elevated urban sewage discharges and agriculture fertilizers usage in river basin are the anthropogenic sources of these heavy metals in river. (author)

  5. Method for restoring contaminants to base levels in previously leached formations

    International Nuclear Information System (INIS)

    Strom, E.T.; Espencheid, W.F.

    1983-01-01

    The present invention relates to a method for restoring to environmentally acceptable levels the soluble contaminants in a subterranean formation that has been subjected to oxidative leaching. The contaminants are defined as those ionic species that when subjected to calcium ions form precipitates which are insoluble in the formation fluids. In accordance with the present invention, soluble calcium values are introduced into the formation. The level of contaminants is monitored and when such reaches the desired level, the introduction of soluble calcium values is stopped. The introduction of calcium values may be achieved in several ways one of which is to inject into the formation an aqueous solution containing therein solubilized calcium values. Another method of introducing calcium values into a formation, is to inject into the formation an aqueous solution containing carbon dioxide to solubilize calcium values, such as calcium carbonates, found in the formation

  6. Environmental survey to assess viral contamination of air and surfaces in hospital settings.

    Science.gov (United States)

    Carducci, A; Verani, M; Lombardi, R; Casini, B; Privitera, G

    2011-03-01

    The presence of pathogenic viruses in healthcare settings represents a serious risk for both staff and patients. Direct viral detection in the environment poses significant technical problems and the indirect indicators currently in use suffer from serious limitations. The aim of this study was to monitor surfaces and air in hospital settings to reveal the presence of hepatitis C virus, human adenovirus, norovirus, human rotavirus and torque teno virus by nucleic acid assays, in parallel with measurements of total bacterial count and haemoglobin presence. In total, 114 surface and 62 air samples were collected. Bacterial contamination was very low (air was 282 cfu/m(3). Overall, 19 (16.7%) surface samples tested positive for viral nucleic acids: one for norovirus, one for human adenovirus and 17 (14.9%) for torque teno virus (TTV). Only this latter virus was directly detected in 10 air samples (16.1%). Haemoglobin was found on two surfaces. No relationship was found between viral, biochemical or bacterial indicators. The data obtained confirm the difficulty of assessing viral contamination using bacterial indicators. The frequent detection of TTV suggests its possible use as an indicator for general viral contamination of the environment. Copyright © 2010 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

  7. Microbiological quality control of single-walled carbon-nanotubes-coated surfaces experimentally contaminated

    International Nuclear Information System (INIS)

    Natalizi, T.; Frioni, A.; Passeri, D.; Pantanella, F.

    2013-01-01

    The emergence of new nanotechnologies involves the spreading of nanoparticles in various fields of human life. Nanoparticles in general and, more specifically, carbon nanotubes have been adopted for many practical approaches i.e.: coatings for medical devices, food process industry and drug delivery. Humans will be increasingly exposed to nanoparticles but the susceptibility of nanostructured materials to microbial colonization in process of manufacturing and storage has not been thoroughly considered. Therefore, the microbiological quality control of nanoparticles plays a pivotal role. Different analytical methods have been attempted for detecting bacterial population contaminating a surface, but no one can be considered fully appropriate. Here, BioTimer Assay (BTA) and conventional sonication followed by colony forming units method (S-CFU) were applied for microbiological quality control of single-walled carbon nanotubes (SWCNTs)-coated surfaces experimentally contaminated with Streptococcus mutans and Pseudomonas aeruginosa. Our results demonstrated that S-CFU is unreliable to actually determine the number of bacteria, contaminating abiotic surfaces, as it does not detach all adherent bacteria and kills part of the bacterial population. Instead, BTA is a reliable method to enumerate bacteria colonizing SWCNTs-coated surfaces and can be considered a useful tool for microbiological quality control of nanomaterials for human use.

  8. Contamination by persistent toxic substances in surface sediment of urban rivers in Chaohu City, China.

    Science.gov (United States)

    Li, Feipeng; Zhang, Haiping; Meng, Xiangzhou; Chen, Ling; Yin, Daqiang

    2012-01-01

    The concentration and spatial distribution of persistent toxic substances (PTS) in the river sediment in Chaohu City, China were investigated. A total of nine surface sediments were collected and the selected PTS pollutants including six heavy metals and nineteen polybrominated diphenyl ethers (PBDEs) were analyzed. The mean heavy metal concentrations (in mg/kg, dry weight) ranged within 0.18-1.53 (Hg), 50.08-200.18 (Cu), 118.70-313.65 (Zn), 50.77-310.85 (Cr), 37.12-92.72 (Pb) and 13.29-197.24 (As), and Cu, Zn and As have been regarded as the main metal pollutants. The levels of PBDEs (1.2-12.1 ng/g) and BDE-209 (2.4-30.5 ng/g) were at the middle level of the global range. BDE-209 was the predominant congener (67.0%-85.7%), which agrees with the fact that technical deca-BDE mixtures are the dominant PBDE formulation in China. The relative high level of PTS pollutants in the western part of the city is probably owing to the intensive agricultural activities and lack of sewerage system there. The ecological risk assessment with the sediment quality guidelines (SOGs) indicates that the urban river sediments in the city have been heavily contaminated by heavy metals with probable ecotoxicological impacts on freshwater organisms and the main toxic pollutants are Hg and As. The results of current study imply that the city, and perhaps many other small cities in China as well, requires immediate pollution control measures with emphasis on not only conventional organic pollutants but also on PTS such as heavy metals and PBDEs.

  9. Transport of contaminants by Arctic sea ice and surface ocean currents

    International Nuclear Information System (INIS)

    Pfirman, S.

    1995-01-01

    Sea ice and ocean currents transport contaminants in the Arctic from source areas on the shelves, to biologically active regions often more than a thousand kilometers away. Coastal regions along the Siberian margin are polluted by discharges of agricultural, industrial and military wastes in river runoff, from atmospheric deposition and ocean dumping. The Kara Sea is of particular concern because of deliberate dumping of radioactive waste, as well as the large input of polluted river water. Contaminants are incorporated in ice during suspension freezing on the shelves, and by atmospheric deposition during drift. Ice releases its contaminant load through brine drainage, surface runoff of snow and meltwater, and when the floe disintegrates. The marginal ice zone, a region of intense biological activity, may also be the site of major contaminant release. Potentially contaminated ice from the Kara Sea is likely to influence the marginal ice zones of the Barents and Greenland seas. From studies conducted to date it appears that sea ice from the Kara Sea does not typically enter the Beaufort Gyre, and thus is unlikely to affect the northern Canadian and Alaskan margins

  10. Occurrence of perchloroethylene in surface water and fish in a river ecosystem affected by groundwater contamination.

    Science.gov (United States)

    Wittlingerová, Zdena; Macháčková, Jiřina; Petruželková, Anna; Zimová, Magdalena

    2016-03-01

    Long-term monitoring of the content of perchloroethylene (PCE) in a river ecosystem affected by groundwater contamination was performed at a site in the Czech Republic. The quality of surface water was monitored quarterly between 1994 and 2013, and fish were collected from the affected ecosystem to analyse the content of PCE in their tissue in 1998, 2011 and 2012. Concentrations of PCE (9-140 μg/kg) in the tissue of fish collected from the contaminated part of the river were elevated compared to the part of the river unaffected by the contamination (ND to 5 μg/kg PCE). The quality of surface water has improved as a result of groundwater remediation during the evaluated period. Before the remedial action, PCE concentrations ranged from 30 to 95 μg/L (1994-1997). Following commencement of remedial activities in September 1997, a decrease in the content of PCE in the surface water to 7.3 μg/L (1998) and further to 1 μg/L (2011) and 1.1 μg/L (2012) led to a progressive decrease in the average concentration of PCE in the fish muscle tissue from 79 μg/kg (1998) to 24 (2011) and 30 μg/kg (2012), respectively. It was determined that the bioconcentration of PCE does not have a linear dependence because the decrease in contamination in the fish muscle tissue is not directly proportional to the decrease in contamination in the river water. The observed average bioconcentration factors were 24 and 28 for the lower concentrations of PCE and 11 for the higher concentrations of PCE in the river. In terms of age, length and weight of the collected fish, weight had the greatest significance for bioconcentration, followed by the length, with age being evaluated as a less significant factor.

  11. Uncertainty of mass discharge estimation from contaminated sites at screening level

    DEFF Research Database (Denmark)

    Thomsen, Nanna Isbak; Troldborg, M.; McKnight, Ursula S.

    Contaminated sites threaten groundwater resources worldwide. The number of contaminated sites is large and there are too few economic resources available to ensure a thorough investigation and remediation of them all. Risk assessment must already be done at a screening level in order to ensure...... consider possible source and hydrogeological descriptions, where each model is believed to be a realistic representation of the given site, based on the current level of information. Parameter uncertainty is quantified using Monte Carlo simulations. For each conceptual model we calculate a transient mass...

  12. Chemical disinfection of non-porous inanimate surfaces experimentally contaminated with four human pathogenic viruses.

    Science.gov (United States)

    Sattar, S A; Springthorpe, V S; Karim, Y; Loro, P

    1989-06-01

    The chemical disinfection of virus-contaminated non-porous inanimate surfaces was investigated using coxsackievirus B3, adenovirus type 5, parainfluenza virus type 3 and coronavirus 229E as representatives of important nosocomial viral pathogens. A 10 microliter amount of the test virus, suspended in either faeces or mucin, was placed onto each stainless steel disk (about 1 cm in diameter) and the inoculum allowed to dry for 1 h under ambient conditions. Sixteen disinfectant formulations were selected for this study based on the findings of an earlier investigation with a human rotavirus. After 1 min exposure to 20 microliters of the disinfectant, the virus from the disks was immediately eluted into tryptose phosphate broth and plaque assayed. Using an efficacy criterion of a 3 log10 or greater reduction in virus infectivity titre and irrespective of the virus suspending medium, only the following five disinfectants proved to be effective against all the four viruses tested: (1) 2% glutaraldehyde normally used as an instrument soak, (2) a strongly alkaline mixture of 0.5% sodium o-benzyl-p-chlorophenate and 0.6% sodium lauryl sulphate, generally used as a domestic disinfectant cleaner for hard surfaces, (3) a 0.04% solution of a quaternary ammonium compound containing 7% hydrochloric acid, which is the basis of many toilet bowl cleaners, (4) chloramine T at a minimum free chlorine level of 3000 p.p.m. and (5) sodium hypochlorite at a minimum free chlorine concentration of 5000 p.p.m. Of those chemicals suitable for use as topical antiseptics, 70% ethanol alone or products containing at least 70% ethanol were ineffective only against coxsackievirus B3. These results emphasize the care needed in selecting chemical disinfectants for routine use in infection control.

  13. The development of the American National Standard 'control of radioactive surface contamination on materials equipment and facilities to be released for uncontrolled use'

    International Nuclear Information System (INIS)

    Shapiro, J.

    1980-01-01

    A new standard submitted by the Health Physics Society Standards Committee to the American National Standards Institute concerning radioactive surface contamination of materials and equipment is discussed. The chronological events in the development of this standard are given. The standard provides criteria for the release for uncontrolled use of materials, equipment and facilities contaminated or potentially contaminated with radioactivity. Permissible contamination limits are specified for: 1) long lived alpha emitters except natural uranium and thorium, 2) more hazardous beta-gamma emitters, 3) less hazardous beta-gamma emitters and 4) natural uranium and thorium. A contamination reference level of 1000 dpm/100 cm 2 for 90 Sr was set as the basis for assigning limits to radionuclides presenting an ingestion hazard and other radionuclides were grouped based on the values of their maximum permissible concentration (MPC) in water relative to 90 Sr. The contamination limit for 239 Pu was chosen as the basis for assigning limits based on MPC in air to radionuclides presenting an inhalation hazard; a value of 100 dpm/100 cm 2 was adopted in the standard. An upper limit of 5000 dpm/100 cm 2 for surface contamination was selected for the standard. (UK)

  14. Field emission and high voltage cleaning of particulate contaminants on extended metallic surfaces

    International Nuclear Information System (INIS)

    Tan, J.; Bonin, B.; Safa, H.

    1996-01-01

    The vacuum insulation properties of extended metallic surfaces depends strongly on their cleanliness. The usual technique to reduce electronic field emission from such surfaces consists in exposing them to very high electric fields during limited periods of time. This kind of processing also reduces the occurrence of vacuum breakdown. The processing of the surface is generally believed to be due to a thermomechanical destruction of the emitting sites, initiated by the emission itself. Comparison of the electric forces vs adherence forces which act on dust particles lying on the surface shows that the processing could also be due simply to the mechanical removal of the dust particles, with a subsequent reduction of field emission from the contaminated surface. (author)

  15. Character and levels of radioactive contamination of underground waters at Semipalatinsk test site

    Energy Technology Data Exchange (ETDEWEB)

    Subbotin, S.; Lukashenko, S.; Turchenko, Y. [Institute of radiation safety and ecology (Kazakhstan)

    2014-07-01

    According to the data of RK government commission, 470 explosions have been set off at the Semipalatinsk Test Site (STS), inclusive of 26 surface, 90 in the air and 354 underground nuclear explosions (UNE), 103 of those have been conducted in tunnels and 251 - in boreholes. Underground nuclear explosions have been conducted at STS in horizontal mines, called - 'tunnels' ('Degelen' test site) and vertical mines called 'boreholes' ('Balapan' and 'Sary-Uzen' test sites). Gopher cavities of boreholes and tunnels are in different geotechnical conditions, that eventually specify migration of radioactive products with underground waters. Central cavities of UNE in holes are located significantly below the level of distribution of underground water. High temperature remains for a long time due to presence of overlying rock mass. High temperatures contribute to formation of thermal convection. When reaching the cavity, the water heat up, dissolve chemical elements and radionuclides and return with them to the water bearing formation. In the major part of 'Balapan' site for underground water of regional basin is characterized by low concentrations of radionuclides. High concentrations of {sup 137}Cs in underground water have been found only in immediate vicinity to 'warfare' boreholes. Formation of radiation situation in the 'Balapan' test site area is also affected by local area of underground water discharge. It is located in the valley of Shagan creek, where the concentration of {sup 3}H reaches 700 kBq/l. Enter of underground water contaminated with tritium into surface water well continue. In this case it is expected that tritium concentration in discharge zone can significantly change, because this migration process depends on hydro geological factors and the amount of atmospheric precipitation. Central cavities of nuclear explosions, made in tunnels, are above the level of underground

  16. Substantiation of rate setting of surface contamination with amino acids, labelled with tritium

    International Nuclear Information System (INIS)

    Zhesko, T.V.

    1987-01-01

    For rate setting of surface contamination with the wide-spread biogenic tritium compounds-protein predecessors-experimental study of skin absorption and skin deposit of amino acids labelled with tritium is carried out on rats. While extrapolating data to people and calculating tolerable skin contamination with 3 H- amino acids, it is supposed that people arm skin, 100-500 cm 2 , has no defects and that the skin surface decontamination after radionuclide contact is carried out with a preparation, efficiency of which is not less than 97%. The value of tolerable skin absorption of tritium amino acids, being 110-550 MBq/year or 4.8 kBq/cm 2 per one working day, is calculated

  17. Portable instrumentation for quantitatively measuring radioactive surface contaminations, including 90Sr

    International Nuclear Information System (INIS)

    Brodzinski, R.L.

    1983-10-01

    In order to measure the effectiveness of decontamination efforts, a quantitative analysis of the radiocontamination is necessary, both before and after decontamination. Since it is desirable to release the decontaminated material for unrestricted use or disposal, the assay equipment must provide adequate sensitivity to measure the radioactivity at or below the release limit. In addition, the instrumentation must be capable of measuring all kinds of radiocontaminants including fission products, activation products, and transuranic materials. Finally, the survey instrumentation must be extremely versatile in order to assay the wide variety of contaminated surfaces in many environments, some of which may be extremely hostile or remote. This communication describes the development and application of portable instrumentation capable of quantitatively measuring most transuranics, activation products, and fission products, including 90 Sr, on almost any contaminated surface in nearly any location

  18. Longer Contact Times Increase Cross-Contamination of Enterobacter aerogenes from Surfaces to Food.

    Science.gov (United States)

    Miranda, Robyn C; Schaffner, Donald W

    2016-11-01

    Bacterial cross-contamination from surfaces to food can contribute to foodborne disease. The cross-contamination rate of Enterobacter aerogenes on household surfaces was evaluated by using scenarios that differed by surface type, food type, contact time (food types were watermelon, bread, bread with butter, and gummy candy. Surfaces (25 cm 2 ) were spot inoculated with 1 ml of inoculum and allowed to dry for 5 h, yielding an approximate concentration of 10 7 CFU/surface. Foods (with a 16-cm 2 contact area) were dropped onto the surfaces from a height of 12.5 cm and left to rest as appropriate. Posttransfer, surfaces and foods were placed in sterile filter bags and homogenized or massaged, diluted, and plated on tryptic soy agar. The transfer rate was quantified as the log percent transfer from the surface to the food. Contact time, food, and surface type all had highly significant effects (P food, while the least bacteria transferred to gummy candy (∼0.1 to 62%). Transfer of bacteria to bread (∼0.02 to 94%) was similar to transfer of bacteria to bread with butter (∼0.02 to 82%), and these transfer rates under a given set of conditions were more variable than with watermelon and gummy candy. The popular notion of the "five-second rule" is that food dropped on the floor and left there for foods (watermelon, bread, bread with butter, and gummy candy), four different contact times (food and the surface, are of equal or greater importance. Some transfer takes place "instantaneously," at times of <1 s, disproving the five-second rule. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  19. Evaluation of surface contamination based on certifiably traceable, internationally accreditable measurements

    International Nuclear Information System (INIS)

    Whitlock, G.D.

    1992-01-01

    National Accreditation and Measurement Service (NAMAS) adopted by the EUROMET agreement requires that the calibration of monitoring instruments be traceable internationally with the objective that radiation hazard assessment be improved. This objective is achieved for Tritium surface contamination by employing calibration sources and evaluation methods which comply with ISO standards including the measurement of activity removable by Volatilization as well as dust. Consideration should be given to organic binding of tritium in the skin with its implications in the event of litigation. (author)

  20. New miniaturized alpha/beta spectrometric system for the surface contamination monitoring and radon personal dosimeter

    International Nuclear Information System (INIS)

    Streil, T.; Oeser, V.; Holfeld, G.

    1998-01-01

    The heart of the new miniaturized alpha/beta spectroscopic system is a Smart Card MCA having a 12 bit resolution and a 32 bit memory for each channel with the size of a cheque card. The system consists of a single or up to 12 alpha spectrometers in a battery powered casing with connectors for direct detector/amplifier module plugging. Surface contamination in the order of 1 Bq/cm 2 of 239 Pu can be measured. (M.D.)

  1. Carbapenem-Resistant Acinetobacter baumannii: Concomitant Contamination of Air and Environmental Surfaces.

    Science.gov (United States)

    Shimose, Luis A; Masuda, Eriko; Sfeir, Maroun; Berbel Caban, Ana; Bueno, Maria X; dePascale, Dennise; Spychala, Caressa N; Cleary, Timothy; Namias, Nicholas; Kett, Daniel H; Doi, Yohei; Munoz-Price, L Silvia

    2016-07-01

    OBJECTIVE To concomitantly determine the differential degrees of air and environmental contamination by Acinetobacter baumannii based on anatomic source of colonization and type of ICU layout (single-occupancy vs open layout). DESIGN Longitudinal prospective surveillance study of air and environmental surfaces in patient rooms. SETTING A 1,500-bed public teaching hospital in Miami, Florida. PATIENTS Consecutive A. baumannii-colonized patients admitted to our ICUs between October 2013 and February 2014. METHODS Air and environmental surfaces of the rooms of A. baumannii-colonized patients were sampled daily for up to 10 days. Pulsed-field gel electrophoresis (PFGE) was used to type and match the matching air, environmental, and clinical A. baumannii isolates. RESULTS A total of 25 A. baumannii-colonized patients were identified during the study period; 17 were colonized in the respiratory tract and 8 were colonized in the rectum. In rooms with rectally colonized patients, 38.3% of air samples were positive for A. baumannii; in rooms of patients with respiratory colonization, 13.1% of air samples were positive (P=.0001). In rooms with rectally colonized patients, 15.5% of environmental samples were positive for A. baumannii; in rooms of patients with respiratory colonization, 9.5% of environmental samples were positive (P=.02). The rates of air contamination in the open-layout and single-occupancy ICUs were 17.9% and 21.8%, respectively (P=.5). Environmental surfaces were positive in 9.5% of instances in open-layout ICUs versus 13.4% in single-occupancy ICUs (P=.09). CONCLUSIONS Air and environmental surface contaminations were significantly greater among rectally colonized patients; however, ICU layout did not influence the rate of contamination. Infect Control Hosp Epidemiol 2016;37:777-781.

  2. Device for determining the gross weight, dose rate, surface contamination and/or nuclide inventory

    International Nuclear Information System (INIS)

    1987-01-01

    Barrels with low nuclide inventories (about 1E6 Bq) and with high inventories (1E13 Bq) are inspected with the barrel inspection system. The system provides a rotating plate, which is part of some scales and a measuring sensor arrangement for this purpose. The surface contamination and nuclide inventories of the 200 litre barrels can be calculated from the weight and radiation detector values. (DG) [de

  3. Chemical disinfection of non-porous inanimate surfaces experimentally contaminated with four human pathogenic viruses.

    OpenAIRE

    Sattar, S. A.; Springthorpe, V. S.; Karim, Y.; Loro, P.

    1989-01-01

    The chemical disinfection of virus-contaminated non-porous inanimate surfaces was investigated using coxsackievirus B3, adenovirus type 5, parainfluenza virus type 3 and coronavirus 229E as representatives of important nosocomial viral pathogens. A 10 microliter amount of the test virus, suspended in either faeces or mucin, was placed onto each stainless steel disk (about 1 cm in diameter) and the inoculum allowed to dry for 1 h under ambient conditions. Sixteen disinfectant formulations were...

  4. Multiple containment for LSA [low specific activity] and SCO [surface contaminated objects] wastes

    International Nuclear Information System (INIS)

    Burgess, M.H.

    1993-09-01

    Radioactive wastes are generally transported in the form of Low Specific Activity (LSA) materials or Surface Contaminated Objects (SCO). This report proposes that a method of acknowledging the beneficial effects of multiple containment for such wastes should be written into the 1996 Edition of the IAEA Transport Regulations. Experience used to assess risks from on-site movements of radioactive material in the UK can be applied to develop safety arguments justifying the alleviation of off-site transport risks. (UK)

  5. Model for the assessment of surface radionuclide 210 Pb contamination indoors due to presence of radon

    International Nuclear Information System (INIS)

    Mrdja, D.; Bikit, I.; Forkapic, S.

    2009-01-01

    The model is based on the fact that the change of indoor radon concentration, which periodically enters the room, affects only on radioactive decay and the inserted amount of radon in each impact, but not on its diffusion out, i.e. escape from the room. The aim of the model is to assess the surface contamination of the room by lead 210 Pb. (author) [sr

  6. Risk assessment based on current release standards for radioactive surface contamination

    International Nuclear Information System (INIS)

    Chen, S.Y.

    1993-09-01

    Standards for uncontrolled releases of radioactive surface contamination have been in existence in the United States for about two decades. Such standards have been issued by various agencies, including the US Department of Energy. This paper reviews the technical basis of published standards, identifies areas in need of revision, provides risk interpretations based on current technical knowledge and the regulatory environment, and offers suggestions for improvements

  7. Detecting buried radium contamination using soil-gas and surface-flux radon meaurements

    International Nuclear Information System (INIS)

    Karp, K.E.

    1988-06-01

    The Technical Measurements Center (TMC) has investigated the effectiveness of using radon soil-gas under surface-flux measurments to locate radium contamination that is buried sufficiently deep to be undetectable by surface gamma methods. At the first test site studied, an indication of a buried source was revealed by mapping anomalous surface-flux and soil-gas concentrations in the near surface overburden. The mapped radon anomalies were found to correspond in rough outline to the shape of the areal extent of the deposit as determined by borehole gamma-ray logs. The 5.9pCi/g radium deposit, buried 2 feet below the surface, went undetected by conventional surface gamma measurements. Similar results were obtained at the second test site where radon and conventional surface gamma measurements were taken in an area having radium concentrations ranging from 13.3 to 341.0 pCi/g at a depth of 4 feet below the surface. The radon methods were found to have a detection limit for buried radium lower than that of the surface gamma methods, as evidenced by the discovery of the 13.3 pCi/g deposit which went undetected by the surface gamma methods. 15 refs., 33 figs., 8 tabs

  8. Detection of fecal contamination on beef meat surfaces using handheld fluorescence imaging device (HFID)

    Science.gov (United States)

    Oh, Mirae; Lee, Hoonsoo; Cho, Hyunjeong; Moon, Sang-Ho; Kim, Eun-Kyung; Kim, Moon S.

    2016-05-01

    Current meat inspection in slaughter plants, for food safety and quality attributes including potential fecal contamination, is conducted through by visual examination human inspectors. A handheld fluorescence-based imaging device (HFID) was developed to be an assistive tool for human inspectors by highlighting contaminated food and food contact surfaces on a display monitor. It can be used under ambient lighting conditions in food processing plants. Critical components of the imaging device includes four 405-nm 10-W LEDs for fluorescence excitation, a charge-coupled device (CCD) camera, optical filter (670 nm used for this study), and Wi-Fi transmitter for broadcasting real-time video/images to monitoring devices such as smartphone and tablet. This study aimed to investigate the effectiveness of HFID in enhancing visual detection of fecal contamination on red meat, fat, and bone surfaces of beef under varying ambient luminous intensities (0, 10, 30, 50 and 70 foot-candles). Overall, diluted feces on fat, red meat and bone areas of beef surfaces were detectable in the 670-nm single-band fluorescence images when using the HFID under 0 to 50 foot-candle ambient lighting.

  9. Mathematical simulation of sediment and contaminant transport in surface waters. Annual report, October 1977--September 1978

    International Nuclear Information System (INIS)

    Onishi, Y.; Arnold, E.M.; Serne, R.J.; Cowan, C.E.; Thompson, F.L.; Mayer, D.W.

    1979-01-01

    Various pathways exist for exposure of humans and biota to radioactive materials released from nuclear facilities. Hydrologic transport (liquid pathway) is one element in the evaluation of the total radiation dose to man. Mathematical models supported by well-planned field data collection programs can be useful tools in assessing the hydrologic transport and ultimate fate of radionuclides. Radionuclides with high distribution coefficients or radionuclides in surface waters with high suspended sediment concentrations are, to a great extent, adsorbed by river and marine sediments. Thus, otherwise dilute contaminants are concentrated. Contaminated sediments may be deposited on the river and ocean beds creating a significant pathway to man. Contaminated bed sediment in turn may become a long-term source of pollution through desorption and resuspension. In order to assess migration and accumulation of radionuclides in surface waters, mathematical models must correctly simulate essential mechanisms of radionuclide transport. The objectives of this study were: (1) to conduct a critical review of (a) radionuclide transport models as well as sediment transport and representative water quality models in rivers, estuaries, oceans, lakes, and reservoirs, and (b) adsorption and desorption mechanisms of radionuclides with sediments in surface waters; (2) to synthesize a mathematical model capable of predicting short- and long-term transport and accumulation of radionuclides in marine environments

  10. Mitigation of cesium and cobalt contamination on the surfaces of RAM packages

    International Nuclear Information System (INIS)

    Krumhansl, J.; Bonhomme, F.; McConnell, P.; Kapoor, A.

    2004-01-01

    Techniques for mitigating the adsorption of 137 Cs and 60 Co on metal surfaces (e.g., RAM packages) exposed to contaminated water (e.g., spent-fuel pools) has been developed and experimentally verified. The techniques are also effective in removing some of the 60 Co and 137 Cs that may have been adsorbed on the surfaces after removal from the contaminated water. The principle for the 137 Cs mitigation technique is based upon ion-exchange processes. In contrast, 60 Co contamination primarily resides in minute particles of CRUD that become lodged on cask surfaces. CRUD is an insoluble Fe-Ni-Cr oxide that forms colloidal-sized particles as stainless steels corrode. Because of the similarity between Ni +2 and Co +2 , CRUD is able to scavenge and retain traces of cobalt as it forms. A number of organic compounds have a great specificity for combining with nickel and cobalt. Ongoing research is investigating the effectiveness of chemical complexing agent, EDTA, with regard to its ability to dissolve the host phase (CRUD) thereby liberating the entrained 60Co into a solution where it can be rinsed away

  11. Linking otolith microchemistry and surface water contamination from natural gas mining.

    Science.gov (United States)

    Keller, David H; Zelanko, Paula M; Gagnon, Joel E; Horwitz, Richard J; Galbraith, Heather S; Velinsky, David J

    2018-09-01

    Unconventional natural gas drilling and the use of hydraulic fracturing technology have expanded rapidly in North America. This expansion has raised concerns of surface water contamination by way of spills and leaks, which may be sporadic, small, and therefore difficult to detect. Here we explore the use of otolith microchemistry as a tool for monitoring surface water contamination from generated waters (GW) of unconventional natural gas drilling. We exposed Brook Trout in the laboratory to three volumetric concentrations of surrogate generated water (SGW) representing GW on day five of drilling. Transects across otolith cross-sections were analyzed for a suite of elements by LA-ICP-MS. Brook Trout exposed to a 0.01-1.0% concentration of SGW for 2, 15, and 30 days showed a significant (p waters and provide support for the use of this technique in natural habitats. To our knowledge, this is the first demonstration of how trace elements in fish otoliths may be used to monitor for surface water contamination from GW. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Surface Sampling Collection and Culture Methods for Escherichia coli in Household Environments with High Fecal Contamination.

    Science.gov (United States)

    Exum, Natalie G; Kosek, Margaret N; Davis, Meghan F; Schwab, Kellogg J

    2017-08-22

    Empiric quantification of environmental fecal contamination is an important step toward understanding the impact that water, sanitation, and hygiene interventions have on reducing enteric infections. There is a need to standardize the methods used for surface sampling in field studies that examine fecal contamination in low-income settings. The dry cloth method presented in this manuscript improves upon the more commonly used swabbing technique that has been shown in the literature to have a low sampling efficiency. The recovery efficiency of a dry electrostatic cloth sampling method was evaluated using Escherichia coli and then applied to household surfaces in Iquitos, Peru, where there is high fecal contamination and enteric infection. Side-by-side measurements were taken from various floor locations within a household at the same time over a three-month period to compare for consistency of quantification of E. coli bacteria. The dry cloth sampling method in the laboratory setting showed 105% (95% Confidence Interval: 98%, 113%) E. coli recovery efficiency off of the cloths. The field application demonstrated strong agreement of side-by-side results (Pearson correlation coefficient for dirt surfaces was 0.83 ( p samples (Pearson (0.53, p method can be utilized in households with high bacterial loads using either continuous (quantitative) or categorical (semi-quantitative) data. The standardization of this low-cost, dry electrostatic cloth sampling method can be used to measure differences between households in intervention and non-intervention arms of randomized trials.

  13. Sources, pathways, and relative risks of contaminants in surface water and groundwater: a perspective prepared for the Walkerton inquiry.

    Science.gov (United States)

    Ritter, Len; Solomon, Keith; Sibley, Paul; Hall, Ken; Keen, Patricia; Mattu, Gevan; Linton, Beth

    2002-01-11

    On a global scale, pathogenic contamination of drinking water poses the most significant health risk to humans, and there have been countless numbers of disease outbreaks and poisonings throughout history resulting from exposure to untreated or poorly treated drinking water. However, significant risks to human health may also result from exposure to nonpathogenic, toxic contaminants that are often globally ubiquitous in waters from which drinking water is derived. With this latter point in mind, the objective of this commission paper is to discuss the primary sources of toxic contaminants in surface waters and groundwater, the pathways through which they move in aquatic environments, factors that affect their concentration and structure along the many transport flow paths, and the relative risks that these contaminants pose to human and environmental health. In assessing the relative risk of toxic contaminants in drinking water to humans, we have organized our discussion to follow the classical risk assessment paradigm, with emphasis placed on risk characterization. In doing so, we have focused predominantly on toxic contaminants that have had a demonstrated or potential effect on human health via exposure through drinking water. In the risk assessment process, understanding the sources and pathways for contaminants in the environment is a crucial step in addressing (and reducing) uncertainty associated with estimating the likelihood of exposure to contaminants in drinking water. More importantly, understanding the sources and pathways of contaminants strengthens our ability to quantify effects through accurate measurement and testing, or to predict the likelihood of effects based on empirical models. Understanding the sources, fate, and concentrations of chemicals in water, in conjunction with assessment of effects, not only forms the basis of risk characterization, but also provides critical information required to render decisions regarding regulatory

  14. Study of luminous phenomena observed on contaminated metallic surfaces submitted to high RF fields

    International Nuclear Information System (INIS)

    Maissa, S.; Junquera, T.; Fouaidy, M.; Le Goff, A.; Bonin, B.; Luong, M.; Safa, H.; Tan, J.

    1995-01-01

    The RF field emission from a sample subjected to high RF fields in a copper cavity has been investigated. The study is focused on the luminous emissions occurring on the RF surface simultaneously with the electron emission. The optical apparatus attached to the cavity permits to observe the evolution of the emitters and the direct effects of the surface conditioning. Also, the parameters of the emitted radiation (intensity, glowing duration, spectral distribution) may provide additional informations on the field emission phenomena. Some results concerning samples intentionally contaminated with particles (metallic or dielectric) are presented. (K.A.)

  15. Surface and subsurface characterization of uranium contamination at the Fernald environmental management site

    International Nuclear Information System (INIS)

    Schilk, A.J.; Perkins, R.W.; Abel, K.H.; Brodzinski, R.L.

    1993-04-01

    The past operations of uranium production and support facilities at several Department of Energy (DOE) sites have occasionally resulted in the local contamination of some surface and subsurface soils, and the three-dimensional distribution of the uranium at these sites must be thoroughly characterized before any effective remedial protocols can be established. To this end, Pacific Northwest Laboratory (PNL) has been tasked by the DOE's Office of Technology Development with adapting, developing, and demonstrating technologies for the measurement of uranium in surface and subsurface soils at the Fernald Uranium in Soils Integrated Demonstration site. These studies are detailed in this report

  16. Contaminant levels and toxicity of sediments and water of Baltimore Harbor and Back River, Maryland

    International Nuclear Information System (INIS)

    Logan, D.T.; Jacobs, F.; Mehrotra, N.

    1995-01-01

    The Patapsco and Back River Watershed drains the Baltimore metropolitan area, Maryland's most heavily industrialized and urbanized region. Due to the intensive development and industrialization of the Baltimore metropolitan area over the past 250 years, high levels of contaminants have been discharged into Baltimore Harbor on the Patapsco River and into the Back River. Pollutants historically discharged include heavy metals, petroleum hydrocarbons, pesticides, cyanide, sewage, other organic chemicals, and nutrients. Sources have included industrial and municipal discharges, sewerage overflows, urban runoff, and leaks and spills from vessels and on-land facilities. The Maryland Department of the Environment undertook this study of ambient conditions as part of a developing strategy to assess and improve conditions in the Chesapeake Bay and its tributaries. Past studies were compiled, evaluated, and synthesized to identify the areas of degraded conditions and contaminants of possible concern. Sediment contaminant levels were assessed using historical sediment chemistry data, Effects Range Low and Median concentrations (ER-L and ER-M) as toxicological benchmarks, and a sum of toxicity units approach for multiple contaminants. Data on toxicity testing and biological monitoring was compared to sediment and water quality data. Fish tissue data were used to examine bioaccumulated chemicals. A computerized Geographical Information System (GIS) was used to manipulate and display complex geographical data. The final identification of areas and chemicals of potential concern relied on a syntheses of these results as well as information on present and past contaminant loadings

  17. Wipe sampling for nicotine as a marker of thirdhand tobacco smoke contamination on surfaces in homes, cars, and hotels.

    Science.gov (United States)

    Quintana, Penelope J E; Matt, Georg E; Chatfield, Dale; Zakarian, Joy M; Fortmann, Addie L; Hoh, Eunha

    2013-09-01

    Secondhand smoke contains a mixture of pollutants that can persist in air, dust, and on surfaces for months or longer. This persistent residue is known as thirdhand smoke (THS). Here, we detail a simple method of wipe sampling for nicotine as a marker of accumulated THS on surfaces. We analyzed findings from 5 real-world studies to investigate the performance of wipe sampling for nicotine on surfaces in homes, cars, and hotels in relation to smoking behavior and smoking restrictions. The intraclass correlation coefficient for side-by-side samples was 0.91 (95% CI: 0.87-0.94). Wipe sampling for nicotine reliably distinguished between private homes, private cars, rental cars, and hotels with and without smoking bans and was significantly positively correlated with other measures of tobacco smoke contamination such as air and dust nicotine. The sensitivity and specificity of possible threshold values (0.1, 1, and 10 μg/m(2)) were evaluated for distinguishing between nonsmoking and smoking environments. Sensitivity was highest at a threshold of 0.1 μg/m(2), with 74%-100% of smoker environments showing nicotine levels above threshold. Specificity was highest at a threshold of 10 μg/m(2), with 81%-100% of nonsmoker environments showing nicotine levels below threshold. The optimal threshold will depend on the desired balance of sensitivity and specificity and on the types of smoking and nonsmoking environments. Surface wipe sampling for nicotine is a reliable, valid, and relatively simple collection method to quantify THS contamination on surfaces across a wide range of field settings and to distinguish between nonsmoking and smoking environments.

  18. Methane Bubbles Transport Particles From Contaminated Sediment to a Lake Surface

    Science.gov (United States)

    Delwiche, K.; Hemond, H.

    2017-12-01

    Methane bubbling from aquatic sediments has long been known to transport carbon to the atmosphere, but new evidence presented here suggests that methane bubbles also transport particulate matter to a lake surface. This transport pathway is of particular importance in lakes with contaminated sediments, as bubble transport could increase human exposure to toxic metals. The Upper Mystic Lake in Arlington, MA has a documented history of methane bubbling and sediment contamination by arsenic and other heavy metals, and we have conducted laboratory and field studies demonstrating that methane bubbles are capable of transporting sediment particles over depths as great as 15 m in Upper Mystic Lake. Methane bubble traps were used in-situ to capture particles adhered to bubble interfaces, and to relate particle mass transport to bubble flux. Laboratory studies were conducted in a custom-made 15 m tall water column to quantify the relationship between water column height and the mass of particulate transport. We then couple this particle transport data with historical estimates of ebullition from Upper Mystic Lake to quantify the significance of bubble-mediated particle transport to heavy metal cycling within the lake. Results suggest that methane bubbles can represent a significant pathway for contaminated sediment to reach surface waters even in relatively deep water bodies. Given the frequent co-occurrence of contaminated sediments and high bubble flux rates, and the potential for human exposure to heavy metals, it will be critical to study the significance of this transport pathway for a range of sediment and contaminant types.

  19. Metals Accumulation and Leaf Surface Anatomy of Murdannia spectabilis Growing in Zn/Cd Contaminated Soil

    Directory of Open Access Journals (Sweden)

    Ladawan Rattanapolsan

    2013-07-01

    Full Text Available Murdannia spectabilis (Kurz Faden was identified as a Zn/Cd hyperaccumulative plant. Leaf surface anatomy of the plant growing in non-contaminated soil (control and Zn/Cd contaminated soil,was studied and compared by a light microscopy and scanning electron microscopy combined with Energy-dispersive X-ray spectroscopy(SEM/EDS. The similarities were reticulate cuticle on epidermises, uniform polygonal cell, stomatal arrangement in six surrounding subsidiary cells, and submarginal sclerenchyma. The dissimilarities were uniserate trichomes spreading on both adaxial and abaxial epidermis of the plants growing in non-contaminated soil, whereas the uniserate trichomes were only on the submarginal-adaxial epidermis of the control plants. The trichomes on leaves of the plants growing in non-contaminated soil were found to have both uniseriate non-glandular and uniseriate glandular trichomes;whereas, leaves of the plants growing in the contaminated soil were merely non-glandular trichomes. The different shape and location of trichomes, the number of stomata and trichome indicated the effect of Zn and Cd on M. spectabilis. The higher percentages of Zn and Cd in the vascular bundle than in the cross section and epidermis areas showed both solutes could move along each route, with diffusion through the symplast and apoplast. The increase of Ca in M. spectabilis growing in Zn/Cd contaminated soil corresponded to the Zn and Cd distributed in the leaves. Zn K-edge and S K-edge XANES spectra proposed that Zn2+ ions were accumulated and/or adsorbed on the epidermis of the tuber, and then absorbed into the root and transport to the xylem. The double peaks of Zn-cysteine in the leaf samples proposed the metal sequestration was by sulphur proteins.

  20. [Contamination levels to room air arising from the use of 99mTc-gas and prevention from the contamination].

    Science.gov (United States)

    Komatani, A; Akutsu, T; Yamaguchi, K; Onodera, Y; Manaka, Y; Takahashi, K

    1996-04-01

    99mTc-gas (TECHNEGAS) is a 99mTc-labeled micro-aerosol which is considered to have different behavior from 133Xe or 81mKr gas. In order to estimate contamination levels to room air arising from the use of 99mTc-gas, filtered expired air during administration and 1, 2, 3, 5, 10 min after the administration were collected in each polyethylene bag. Radioactivities of the polyethylene bags, used filter and the lung were measured with 3-head scintillation camera. The activity of the expired air diminished within 6-10 min and about 5% of whole discharged 99mTc-gas was released to room air. The activity of the used filter was two times of the lung. According to these results, it is recommended that the 99mTc-gas may be administrated in a exclusive room. The administrated patient and used filter must be remain in the exclusive room.

  1. Radon-induced surface contaminations in neutrinoless double beta decay and dark matter experiments

    International Nuclear Information System (INIS)

    Pattavina, L.

    2011-01-01

    In experiments looking for rare events, like neutrinoless double beta decay (DBD0ν) and dark matter search (DM), one of the main issues is to increase the experimental sensitivity through the material selection and production. The background contribution coming from the materials used for the detector realization has to be minimized. Moreover the net reduction of the background produced by the bulk part of the apparatus has raised concerns about the background contribution coming from the surfaces. Many procedures and techniques were developed during the last years in order to remove and to minimize the presence of possible contaminants on detector surfaces. To succeed in this strategy a big effort was put in defining all possible mechanisms that lead to surface contaminations, as well as specific cleaning procedures, which are able to reduce and control the surface radioactivity. The presence in air and gases of possible radioactive elements that can stick on the detector surfaces can lead to a recontamination process that will vanish all the applied cleaning procedures. Here is presented and analyzed the contribution to the background of rare events experiments like CUORE experiment (DBD0ν) and EDELWEISS experiment (DM) produced by an exposure of their detector components to a big activity of 222 Rn, radioactive daughter isotope from the 238 U chain. (author)

  2. Nitrate and nitrite contamination of sub-surface water in some areas of North West Frontier Province (N.W.F.P.) Pakistan

    International Nuclear Information System (INIS)

    Khan, M.; Khawaja, M.A.; Imdadullah

    1998-01-01

    Over the past few years, nitrate and nitrite contamination of sub-surface water samples from Peshawar, Charsada, Mardan and Nowshera districts of NWFP has been studied. In all the areas under study, nitrate concentration of sub-surface water was found to be below WHO approved limit of 45 mg/l. Whereas city area after 1987 showed a decreasing level of nitrate contamination of sub-surface water, it appeared to be on the increase in water samples from the outskirts of Peshawar-Charsada road. No uniform increasing or decreasing patterns of nitrate contamination were observed for water samples from cantonment, University and Hayatabad, areas of Mardan, Charsada and Nowshera under study. The nitrate contamination of sub-surface water appeared to be due to both the agricultural activities as well as human and animal wastes. A few sub-surface water samples from Peshawar city, Mardan and Nowshera areas indicated high concentration of nitrite, which is alarming in view of the earlier reports showing absence of nitrite in water samples from these areas. However, since 1993, nitrite presence has not been detected in sub-surface water samples from all the areas under present investigation. (author)

  3. Circulating levels of environmental contaminants are associated with dietary patterns in older adults.

    Science.gov (United States)

    Ax, Erika; Lampa, Erik; Lind, Lars; Salihovic, Samira; van Bavel, Bert; Cederholm, Tommy; Sjögren, Per; Lind, P Monica

    2015-02-01

    Food intake contributes substantially to our exposure to environmental contaminants. Still, little is known about our dietary habits' contribution to exposure variability. The aim of this study was to assess circulating levels of environmental contaminants in relation to predefined dietary patterns in an elderly Swedish population. Dietary data and serum concentrations of environmental contaminants were obtained from 844 70-year-old Swedish subjects (50% women) in the Prospective Investigation of the Vasculature in Uppsala Seniors (PIVUS) study. Dietary data from 7-day food records was used to assess adherence to a Mediterranean-like diet, a low carbohydrate-high protein diet and the WHO dietary recommendations. Circulating levels of 6 polychlorinated biphenyl markers, 3 organochlorine pesticides, 1 dioxin and 1 polybrominated diphenyl ether, the metals cadmium, lead, mercury and aluminum and serum levels of bisphenol A and 4 phthalate metabolites were investigated in relation to dietary patterns in multivariate linear regression models. A Mediterranean-like diet was positively associated with levels of several polychlorinated biphenyls (118, 126, 153, and 209), trans-nonachlor and mercury. A low carbohydrate-high protein diet was positively associated with polychlorinated biphenyls 118 and 153, trans-nonachlor, hexachlorobenzene and p, p'-dichlorodiphenyldichloroethylene, mercury and lead. The WHO recommended diet was negatively related to levels of dioxin and lead, and borderline positively to polychlorinated biphenyl 118 and trans-nonachlor. Dietary patterns were associated in diverse manners with circulating levels of environmental contaminants in this elderly Swedish population. Following the WHO dietary recommendations seems to be associated with a lower burden of environmental contaminants. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Organic Contaminant Levels in Three Fish Species Downchannel from the Los Alamos National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Gonzales, G.J.; Fresquez, P.R.; Beveridge, J.W.

    1999-06-01

    The LANL contribution, if any, to organic contaminant levels in the common carp, the channel catfish, and the white sucker in the Rio Grande appear to be small; however, low sample sizes, high variation, and potential interaction of species effect with location treatment effect require additional sampling and analysis.

  5. The analysis of the level of radioactive contamination of agricultural lands in Mogilev region [Belarus

    International Nuclear Information System (INIS)

    Komleva, S.M.

    2010-01-01

    In the conditions of the Republic of Belarus there was analyzed the present level of radioactive situation and contamination of areas of agricultural companies with radiocesium at in Mogilev region. There were suggested methodical approaches on organizing the use of the lands in such a way as to get the minimum content of radionuclides in the manufactured products

  6. Examination of background contamination levels for gas counting and AMS target preparation in Trondheim

    DEFF Research Database (Denmark)

    Gulliksen, S.; Thomsen, M.S.

    1992-01-01

    conventional gas proportional counting (GPC) system. We have also studied contamination levels of our target preparation for C-14 accelerator mass spectrometry (AMS) dating in Uppsala. A significant lower background is obtained for Icelandic double spar than for marbles, probably due to a crystal structure...

  7. Determination of the plutonium contamination level in biological samples by liquid scintillation

    International Nuclear Information System (INIS)

    Willemot, J.M.; Verry, M.; Lataillade, G.

    1989-01-01

    Usual radiochemical processes are unable to carry out without delay the very large number of analyses as required in plutonium toxicology studies. Liquid scintillation is the best method to quickly determine plutonium contamination levels in most various samples (bone, organs,...) [fr

  8. Clearance of surface-contaminated objects from the controlled area of a nuclear facility. Application of the SUDOQU methodology

    Energy Technology Data Exchange (ETDEWEB)

    Russo, F.; Mommaert, C. [Bel V, Brussels (Belgium); Dillen, T. van [National Institute for Public Health and the Environment (RIVM), Bilthoven (Netherlands)

    2018-01-15

    The lack of clearly defined surface-clearance levels in the Belgian regulation led Bel V to start a collaboration with the Dutch National Institute for Public Health and the Environment (RIVM) to evaluate the applicability of the SUDOQU methodology for the derivation of nuclide-specific surface-clearance criteria for objects released from nuclear facilities. SUDOQU is a methodology for the dose assessment of exposure to a surface-contaminated object, with the innovative assumption of a time-dependent surface activity whose evolution is influenced by removal and deposition mechanisms. In this work, calculations were performed to evaluate the annual effective dose resulting from the use of a typical office item, e.g. a bookcase. Preliminary results allow understanding the interdependencies between the model's underlying mechanisms, and show a strong sensitivity to the main input parameters. The results were benchmarked against those from a model described in Radiation Protection 101, to investigate the impact of the model's main assumptions. Results of the two models were in good agreement. The SUDOQU methodology appears to be a flexible and powerful tool, suitable for the proposed application. Therefore, the project will be extended to more generic study cases, to eventually develop surface-clearance levels applicable to objects leaving nuclear facilities.

  9. A DEVICE TO MEASURE LOW LEVELS OF RADIOACTIVE CONTAMINANTS IN ULTRA-CLEAN MATERIALS

    International Nuclear Information System (INIS)

    James H Reeves; Matthew Kauer

    2006-01-01

    detector measuring 6 inch x 6 inch x 6 inch was fitted with wave length shifting fibers that allowed the light from ionizing radiation to be collected and transmitted outside the massive shield to photomultiplier tubes and electronics. The detector was calibrated for energy and detection efficiency and low resolution background spectra were collected. Results from these measurements show the figure of merit (using: efficiency/square root of background) for this plastic scintillation counting technique to be ∼15 times better than for a 2 kg germanium detector for measuring surface contamination from atmospheric 222Rn daughters (210Pb, 210Bi, and 210Po). These daughter radionuclides are normally deposited everywhere onto all materials exposed to air. The results are encouraging and indicate that plastic scintillation counting techniques can be of benefit to the public by making available very sensitive counters for screening ultra-low background materials at an affordable cost. However, in order to reach the level required a multi element array of thin plastic scintillator sheets must be developed that will allow many thin samples to be counted at one time. In addition, more sophisticated light detection hardware, electronics, and computer software is needed

  10. Study of the sediment contamination levels in a mangrove swamp polluted by a marine oil spill

    International Nuclear Information System (INIS)

    Wong, T.W.Y.; Ke, L.; Wong, Y.S.; Tam, N.F.Y.

    2002-01-01

    The pattern of oil retention in mangrove sediments was studied in an effort to determine the temporal changes of petroleum hydrocarbon concentrations and composition several months after oil spills occur. Mangroves are inter-tidal wetlands in tropical and subtropical coastlines. Due to the anoxic and water logging characteristics of mangrove sediments, oil residues linger much longer in these wetlands compared to other coastal habitats. In November 2000, an accidental oil spill occurred in the Pearl River Estuary in which approximately 230,000 litres of crude oil was leaked from an oil tanker. The spilled oil migrated to the YiO, a typical mangrove swamp in Hong Kong Special Administrative Region. The degree of oil contamination in the sediments depended on the sediment texture and topography of the mangrove. The total petroleum hydrocarbon (TPH) concentration of the sediments in the most affected area near a freshwater creek flowing into the sea was 130 times higher than normal, one month after the accident. The mean TPH concentration was 2862 ug/g of dry sediment while the mean carbon preference index was 1.22 compared to the background value of 3.97. The temporal changes of the petroleum hydrocarbon level in 5 defined areas were examined for 7 months after the spill. The most polluted area next to the creek was determined to have very high TPH levels in the muddy sediments even 7 months after the spill. Oil residues infiltrated as deep as 20 cm into the sediments, making it more difficult to degrade than surface pollution and posing long-term adverse effects on trees in the area. It was determined that with growing industrialization and increasing demands for fuel and energy supply, mangroves in South China should be ranked as top priority for protection from oil spills. 19 refs., 6 tabs., 6 figs

  11. Study of the sediment contamination levels in a mangrove swamp polluted by a marine oil spill

    Energy Technology Data Exchange (ETDEWEB)

    Wong, T.W.Y.; Ke, L.; Wong, Y.S.; Tam, N.F.Y. [City University of Hong Kong, Hong Kong SAR (China)

    2002-07-01

    The pattern of oil retention in mangrove sediments was studied in an effort to determine the temporal changes of petroleum hydrocarbon concentrations and composition several months after oil spills occur. Mangroves are inter-tidal wetlands in tropical and subtropical coastlines. Due to the anoxic and water logging characteristics of mangrove sediments, oil residues linger much longer in these wetlands compared to other coastal habitats. In November 2000, an accidental oil spill occurred in the Pearl River Estuary in which approximately 230,000 litres of crude oil was leaked from an oil tanker. The spilled oil migrated to the YiO, a typical mangrove swamp in Hong Kong Special Administrative Region. The degree of oil contamination in the sediments depended on the sediment texture and topography of the mangrove. The total petroleum hydrocarbon (TPH) concentration of the sediments in the most affected area near a freshwater creek flowing into the sea was 130 times higher than normal, one month after the accident. The mean TPH concentration was 2862 ug/g of dry sediment while the mean carbon preference index was 1.22 compared to the background value of 3.97. The temporal changes of the petroleum hydrocarbon level in 5 defined areas were examined for 7 months after the spill. The most polluted area next to the creek was determined to have very high TPH levels in the muddy sediments even 7 months after the spill. Oil residues infiltrated as deep as 20 cm into the sediments, making it more difficult to degrade than surface pollution and posing long-term adverse effects on trees in the area. It was determined that with growing industrialization and increasing demands for fuel and energy supply, mangroves in South China should be ranked as top priority for protection from oil spills. 19 refs., 6 tabs., 6 figs.

  12. Using Contaminant Transport Modeling to Determine Historical Discharges at the Surface

    Science.gov (United States)

    Fogwell, T. W.

    2013-12-01

    When it is determined that a contaminated site needs to be remediated, the issue of who is going to pay for that remediation is an immediate concern. This means that there needs to be a determination of who the responsible parties are for the existing contamination. Seldom is it the case that records have been made and kept of the surface contaminant discharges. In many cases it is possible to determine the relative amount of contaminant discharge at the surface of the various responsible parties by employing a careful analysis of the history of contaminant transport through the surface, through the vadose zone, and within the saturated zone. The process begins with the development of a dynamic conceptual site model that takes into account the important features of the transport of the contaminants through the vadose zone and in the groundwater. The parameters for this model can be derived from flow data available for the site. The resulting contaminant transport model is a composite of the vadose zone transport model, together with the saturated zone (groundwater) flow model. Any calibration of the model should be carefully employed in order to avoid using information about the conclusions of the relative discharge amounts of the responsible parties in determining the calibrated parameters. Determination of the leading edge of the plume is an important first step. It is associated with the first discharges from the surface of the site. If there were several discharging parties at the same time, then it is important to establish a chemical or isotopic signature of the chemicals that were discharged. The time duration of the first discharger needs to be determined as accurately as possible in order to establish the appropriate characterization of the leading portion of the resulting plume in the groundwater. The information about the first discharger and the resulting part of the plume associated with this discharger serves as a basis for the determination of the

  13. Uptake of radionuclides by wheat roots with respect to location of contamination below the surface

    International Nuclear Information System (INIS)

    Suvornmongkhol, Narumon.

    1996-01-01

    The behaviour of 85 Sr, 137 Cs, 54 Mn and 60 Co in terms of plant availability in near surface soil and their root uptake was studied as a function of the location of contamination in the soil profile. Wheat (Triticum aestivum) was employed and the study programme involved both column and hydroponic studies. In the column studies, columns were packed with sandy soil, and either homogeneously or discretely contaminated with the radionuclides, and the water table maintained manually at 3 cm from the bottom. In the discrete contamination, the location of contamination was varied (0-5, 25-30 or 45-50 cm from the top). Wheat plants were grown to maturity in these columns, and harvested at different growth stages to examine radioactivity uptake and its subsequent translocation within the plants. The movement of radionuclides within the soil as well as the soil physicochemical properties were also investigated. The short term uptake kinetics of the hydroponically grown plants during ontogenesis were also studied, both with excised roots and intact plants. The excised root experiment was aimed at investigating the radionuclide by roots of different orders. (author)

  14. Occurrence and behavior of emerging contaminants in surface water and a restored wetland.

    Science.gov (United States)

    Matamoros, Víctor; Arias, Carlos A; Nguyen, Loc Xuan; Salvadó, Victòria; Brix, Hans

    2012-08-01

    Pollution mitigation is an important target for restored wetlands, and although there is much information in relation to nutrient removal, little attention has been paid to emerging contaminants. This paper reports on the occurrence and attenuation capacity of 17 emerging contaminants in a restored wetland and two rivers in North-East Denmark. The compounds belong to the groups of pharmaceuticals, fragrances, antiseptics, fire retardants, pesticides, and plasticizers. Concentrations in surface waters ranged from 2 to 1476 ng L(-1). The compounds with the highest concentrations were diclofenac, 2-methyl-4-chlorophenoxyacetic acid (MCPA), caffeine, and tris(2-chloroethyl) phosphate (TCEP). The herbicide concentrations increased after a rain-fall event, demonstrating the agricultural run-off origin of these compounds, whereas the concentration of the other emerging contaminants was rather conservative. The mitigation capacity of the restored wetland for the compounds ranged from no attenuation to 84% attenuation (19% on average). Hence, restored wetlands may be considered as a feasible alternative for mitigating emerging contaminants from river waters. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Resistance to disinfection of a polymicrobial association contaminating the surface of elastomeric dental impressions.

    Science.gov (United States)

    Giammanco, Giovanni M; Melilli, Dario; Rallo, Antonio; Pecorella, Sonia; Mammina, Caterina; Pizzo, Giuseppe

    2009-04-01

    The aim of this study was to evaluate the ability to resist disinfection of a polymicrobial association contaminating the surface of dental impressions obtained with two different elastomers: a polyether (Impregum) and an addition-polymerized silicone (Elite). Impressions were contaminated with a mixture of three biofilm-forming microorganisms (Staphylococcus aureus, Pseudomonas aeruginosa and Candida albicans) and disinfected immediately after contamination, or after microbial layers were allowed to develop during a six-hour storage. Two commercial disinfectants were tested: MD 520 containing 0.5% glutaraldehyde and Sterigum Powder without glutaraldehyde. Residual contamination was recovered by mechanical rinsing immediately after disinfection and after a six-hour storage of disinfected impressions, and assessed by colony counting. Both disinfectants tested were shown to be effective in reducing the microbial presence on the impression materials, achieving at least a 102 reduction of microbial counts compared to water rinsing. However, Sterigum was generally less effective on the Elite elastomer and could not grant disinfection on six-hour aged P. aeruginosa and C. albicans microbial layers. The results of this study suggest that the materials used for the impressions influence the efficacy of disinfection. Disinfectants should be tested according to conditions encountered in everyday clinical practice and the need for immediate disinfection of impressions should be clearly indicated by manufacturers.

  16. Heavy metals in soils along unpaved roads in south west Cameroon: Contamination levels and health risks.

    Science.gov (United States)

    Ngole-Jeme, Veronica M

    2016-04-01

    Soils enriched with heavy metals from vehicular emission present a significant exposure route of heavy metals to individuals using unpaved roads. This study assessed the extent of Cd, Cr, Co, Cu, Ni, Pb and Zn contamination of soils along unpaved roads in Cameroon, and the health risks presented by incidental ingestion and dermal contact with the soils using metal contamination factor (CF) pollution load index, hazard quotients (HQ) and chronic hazard index (CHI). CF values obtained (0.9-12.2) indicate moderate to high contamination levels. HQ values for Cr, Cd and Pb exceeded the reference doses. Moderate health hazard exists for road users in the areas with intense anthropogenic activities and high average daily traffic (ADT) volume according to CHI values (1-4) obtained. The economy and quality of life in cities with unpaved roads could be threatened by health challenges resulting from long-term exposure to heavy metal derived from high ADT volumes.

  17. Direct-scanning alpha spectrometer for americium and plutonium contamination on highly-enriched uranium surfaces

    International Nuclear Information System (INIS)

    Ward, W.C.; Martinez, H.E.; Abeyta, C.L.; Morgan, A.N.; Nelson, T.O.

    1997-01-01

    Trace Pu 239 and Am 241 contamination on a surface whose alpha count is dominated by U 235 and U 234 decay has been successfully quantified by counting swipes in external alpha spectroscopy chambers. The swipe process, however, is labor intensive and subject to uncertainties in the swiping process as well as degraded spectral resolution due to the presence of the swipe material. A multichannel instrument for automated in situ measurements of interior and exterior contamination has been developed which incorporates a rotary table, 13 fixed ion-implanted silicon detectors, and spectroscopy electronics. Custom software was written to allow alpha spectrometer to function as a virtual instrument in the LabView environment. This system gives improved speed and resolution as well as a complete log of the location of areas of high surface contamination, a feature not practical to obtain by other methods, and one which opens the possibility of long term studies such as Pu outgrowth evaluation employing the instrument. The authors present performance data as well as system integration, calibration, control, and dynamic geometric efficiency calculations related to the design of this and next generation systems

  18. Removal of contaminated concrete surfaces by microwave heating: Phase 1 results

    International Nuclear Information System (INIS)

    White, T.L.; Grubb, R.G.; Pugh, L.P.; Foster, D. Jr.; Box, W.D.

    1992-01-01

    Oak Ridge National Laboratory (ORNL) is developing a microwave heating process to remove radiologically contaminated surface layers from concrete. The microwave energy is directed at the concrete surface and heats the concrete and free water present in the concrete matrix. Continued heating produces steam-pressure-induced mechanical stresses that cause the concrete surface to burst. The concrete particles from this steam explosion are small enough to be removed by a vacuum system, yet less than 1% of the debris is small enough to pose an airborne contamination hazard. The first phase of this program has demonstrated reliable removal of noncontaminated concrete surfaces at frequencies of 2.45 GHz and 10.6 GHz. Continuous concrete removal rates of 1.07 cm 3 /s with 5.2 kW of 2.45.-GHz power and 2.11 cm 3 /s with 3.6 kW of 10.6-GHz power have been demonstrated. Figures-of-merit for microwave removal of concrete have been calculated to be 0.21 cm 3 /s/kW at 2.45 GHz and 0.59 cm 3 /s/kW at 10.6 GHz. The amount of concrete removed in a single pass can be controlled by choosing the frequency and power of the microwave system

  19. Suitability of artificial sweeteners as indicators of raw wastewater contamination in surface water and groundwater.

    Science.gov (United States)

    Tran, Ngoc Han; Hu, Jiangyong; Li, Jinhua; Ong, Say Leong

    2014-01-01

    There is no quantitative data on the occurrence of artificial sweeteners in the aquatic environment in Southeast Asian countries, particularly no information on their suitability as indicators of raw wastewater contamination on surface water and groundwater. This study provided the first quantitative information on the occurrence of artificial sweeteners in raw wastewater, surface water and groundwater in the urban catchment area in Singapore. Acesulfame, cyclamate, saccharin, and sucralose were ubiquitous in raw wastewater samples at concentrations in the range of ng/L-μg/L, while other sweeteners were not found or found only in a few of the raw wastewater samples. Residential and commercial effluents were demonstrated to be the two main sources of artificial sweeteners entering the municipal sewer systems. Relatively higher concentrations of the detected sweeteners were frequently found in surface waters at the sampling sites located in the residential/commercial areas. No significant difference in the concentrations of the detected sweeteners in surface water or groundwater was noted between wet and dry weather conditions (unpaired T-test, p> 0.05). Relatively higher concentrations and detection frequencies of acesulfame, cyclamate and saccharin in surface water samples were observed at the potentially impacted sampling sites, while these sweeteners were absent in most of the background surface water samples. Similarly, acesulfame, cyclamate, and saccharin were found in most groundwater samples at the monitoring well (GW6), which is located close to known leaking sewer segment; whereas these were absent in the background monitoring well, which is located in the catchment with no known wastewater sources. Taken together, the results suggest that acesulfame, cyclamate, and saccharin can be used as potential indicators of raw wastewater contamination in surface water and groundwater. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Surface contamination of spent fuel convoys - resumption of transport in France

    International Nuclear Information System (INIS)

    Pertuis, V.

    2000-01-01

    In France, 1998 was marked by the transport of spent fuel from EDF plants being suspended and then resumed. From the time the first inspections were carried out by the Nuclear Installations Safety Directorate (NISD), in charge of monitoring radioactive and fissile material for civil use since June 1997, surface contamination was found in a high percentage of packages and/or wagons containing spent fuel. The different expert appraisals showed that this had no consequences for the health of the public or of workers. Aiming at the resumption of transport, EDF and Cogema presented to the safety authority a plan of action including an increase in monitoring (number of points and cross-checking by SGS Qualitest), more widespread observance of good practices resulting from analyses by EDF and conclusions of its nuclear inspectorate, and an improvement in radiological cleanliness in the area where casks were loaded. During the inspections carried out at EDF plants, the NISD verified the application of this plan. Several observations were, nevertheless, made regarding maintenance of equipment, failure to apply procedures on a corporate level and the traceability of certain operations. The measures taken to sufficiently inform the public were applied. The NISD is continuing its monitoring actions to ensure that all EDF plants adopt best practices. However, the overall clean-up of EDF plants is a long-term operation. Finally, the NISD is continuing its monitoring of the different stages of spent fuel transport as well as other types of transport of radioactive materials associated with nuclear activities. (author)

  1. Innovative technology for expedited site remediation of extensive surface and subsurface contamination

    International Nuclear Information System (INIS)

    Audibert, J.M.E.; Lew, L.R.

    1994-01-01

    Large scale surface and subsurface contamination resulted from numerous releases of feed stock, process streams, waste streams, and final product at a major chemical plant. Soil and groundwater was contaminated by numerous compounds including lead, tetraethyl lead, ethylene dibromide, ethylene dichloride, and toluene. The state administrative order dictated that the site be investigated fully, that remedial alternative be evaluated, and that the site be remediated within a year period. Because of the acute toxicity and extreme volatility of tetraethyl lead and other organic compounds present at the site and the short time frame ordered by the regulators, innovative approaches were needed to carry out the remediation while protecting plant workers, remediation workers, and the public

  2. Evaluation of wastewater contaminant transport in surface waters using verified Lagrangian sampling

    Science.gov (United States)

    Antweiler, Ronald C.; Writer, Jeffrey H.; Murphy, Sheila F.

    2014-01-01

    Contaminants released from wastewater treatment plants can persist in surface waters for substantial distances. Much research has gone into evaluating the fate and transport of these contaminants, but this work has often assumed constant flow from wastewater treatment plants. However, effluent discharge commonly varies widely over a 24-hour period, and this variation controls contaminant loading and can profoundly influence interpretations of environmental data. We show that methodologies relying on the normalization of downstream data to conservative elements can give spurious results, and should not be used unless it can be verified that the same parcel of water was sampled. Lagrangian sampling, which in theory samples the same water parcel as it moves downstream (the Lagrangian parcel), links hydrologic and chemical transformation processes so that the in-stream fate of wastewater contaminants can be quantitatively evaluated. However, precise Lagrangian sampling is difficult, and small deviations – such as missing the Lagrangian parcel by less than 1 h – can cause large differences in measured concentrations of all dissolved compounds at downstream sites, leading to erroneous conclusions regarding in-stream processes controlling the fate and transport of wastewater contaminants. Therefore, we have developed a method termed “verified Lagrangian” sampling, which can be used to determine if the Lagrangian parcel was actually sampled, and if it was not, a means for correcting the data to reflect the concentrations which would have been obtained had the Lagrangian parcel been sampled. To apply the method, it is necessary to have concentration data for a number of conservative constituents from the upstream, effluent, and downstream sites, along with upstream and effluent concentrations that are constant over the short-term (typically 2–4 h). These corrections can subsequently be applied to all data, including non-conservative constituents. Finally, we

  3. Evaluation of wastewater contaminant transport in surface waters using verified Lagrangian sampling.

    Science.gov (United States)

    Antweiler, Ronald C; Writer, Jeffrey H; Murphy, Sheila F

    2014-02-01

    Contaminants released from wastewater treatment plants can persist in surface waters for substantial distances. Much research has gone into evaluating the fate and transport of these contaminants, but this work has often assumed constant flow from wastewater treatment plants. However, effluent discharge commonly varies widely over a 24-hour period, and this variation controls contaminant loading and can profoundly influence interpretations of environmental data. We show that methodologies relying on the normalization of downstream data to conservative elements can give spurious results, and should not be used unless it can be verified that the same parcel of water was sampled. Lagrangian sampling, which in theory samples the same water parcel as it moves downstream (the Lagrangian parcel), links hydrologic and chemical transformation processes so that the in-stream fate of wastewater contaminants can be quantitatively evaluated. However, precise Lagrangian sampling is difficult, and small deviations - such as missing the Lagrangian parcel by less than 1h - can cause large differences in measured concentrations of all dissolved compounds at downstream sites, leading to erroneous conclusions regarding in-stream processes controlling the fate and transport of wastewater contaminants. Therefore, we have developed a method termed "verified Lagrangian" sampling, which can be used to determine if the Lagrangian parcel was actually sampled, and if it was not, a means for correcting the data to reflect the concentrations which would have been obtained had the Lagrangian parcel been sampled. To apply the method, it is necessary to have concentration data for a number of conservative constituents from the upstream, effluent, and downstream sites, along with upstream and effluent concentrations that are constant over the short-term (typically 2-4h). These corrections can subsequently be applied to all data, including non-conservative constituents. Finally, we show how data

  4. Advanced LWIR hyperspectral sensor for on-the-move proximal detection of liquid/solid contaminants on surfaces

    Science.gov (United States)

    Giblin, Jay P.; Dixon, John; Dupuis, Julia R.; Cosofret, Bogdan R.; Marinelli, William J.

    2017-05-01

    Sensor technologies capable of detecting low vapor pressure liquid surface contaminants, as well as solids, in a noncontact fashion while on-the-move continues to be an important need for the U.S. Army. In this paper, we discuss the development of a long-wave infrared (LWIR, 8-10.5 μm) spatial heterodyne spectrometer coupled with an LWIR illuminator and an automated detection algorithm for detection of surface contaminants from a moving vehicle. The system is designed to detect surface contaminants by repetitively collecting LWIR reflectance spectra of the ground. Detection and identification of surface contaminants is based on spectral correlation of the measured LWIR ground reflectance spectra with high fidelity library spectra and the system's cumulative binary detection response from the sampled ground. We present the concepts of the detection algorithm through a discussion of the system signal model. In addition, we present reflectance spectra of surfaces contaminated with a liquid CWA simulant, triethyl phosphate (TEP), and a solid simulant, acetaminophen acquired while the sensor was stationary and on-the-move. Surfaces included CARC painted steel, asphalt, concrete, and sand. The data collected was analyzed to determine the probability of detecting 800 μm diameter contaminant particles at a 0.5 g/m2 areal density with the SHSCAD traversing a surface.

  5. Surface tailored organobentonite enhances bacterial proliferation and phenanthrene biodegradation under cadmium co-contamination

    International Nuclear Information System (INIS)

    Mandal, Asit; Biswas, Bhabananda; Sarkar, Binoy; Patra, Ashok K.; Naidu, Ravi

    2016-01-01

    Co-contamination of soil and water with polycyclic aromatic hydrocarbon (PAH) and heavy metals makes biodegradation of the former extremely challenging. Modified clay-modulated microbial degradation provides a novel insight in addressing this issue. This study was conducted to evaluate the growth and phenanthrene degradation performance of Mycobacterium gilvum VF1 in the presence of a palmitic acid (PA)-grafted Arquad® 2HT-75-based organobentonite in cadmium (Cd)-phenanthrene co-contaminated water. The PA-grafted organobentonite (ABP) adsorbed a slightly greater quantity of Cd than bentonite at up to 30 mg L"−"1 metal concentration, but its highly negative surface charge imparted by carboxylic groups indicated the potential of being a significantly superior adsorbent of Cd at higher metal concentrations. In systems co-contained with Cd (5 and 10 mg L"−"1), the Arquad® 2HT-75-modified bentonite (AB) and PA-grafted organobentonite (ABP) resulted in a significantly higher (72–78%) degradation of phenanthrene than bentonite (62%) by the bacterium. The growth and proliferation of bacteria were supported by ABP which not only eliminated Cd toxicity through adsorption but also created a congenial microenvironment for bacterial survival. The macromolecules produced during ABP–bacteria interaction could form a stable clay-bacterial cluster by overcoming the electrostatic repulsion among individual components. Findings of this study provide new insights for designing clay modulated PAH bioremediation technologies in mixed-contaminated water and soil. - Highlights: • Surface tailored organobentonite synthesised and characterised • Modified clay adsorbs Cd and reduces toxicity to Mycobacterium gilvum. • It creates congenial microenvironment for bacterial survival. • It enhances phenanthrene biodegradation in metal co-contaminated condition.

  6. Surface tailored organobentonite enhances bacterial proliferation and phenanthrene biodegradation under cadmium co-contamination

    Energy Technology Data Exchange (ETDEWEB)

    Mandal, Asit [Future Industries Institute (formerly Centre for Environmental Risk Assessment and Remediation), University of South Australia, Mawson Lakes, SA 5095 (Australia); Indian Council of Agricultural Research (ICAR), Indian Institute of Soil Science, Bhopal (India); Biswas, Bhabananda [Future Industries Institute (formerly Centre for Environmental Risk Assessment and Remediation), University of South Australia, Mawson Lakes, SA 5095 (Australia); Cooperative Research Centre for Contamination Assessment and Remediation of the Environment (CRC CARE), ACT Building, University of Newcastle, Callaghan, NSW 2308 (Australia); Sarkar, Binoy, E-mail: binoy.sarkar@unisa.edu.au [Future Industries Institute (formerly Centre for Environmental Risk Assessment and Remediation), University of South Australia, Mawson Lakes, SA 5095 (Australia); Cooperative Research Centre for Contamination Assessment and Remediation of the Environment (CRC CARE), ACT Building, University of Newcastle, Callaghan, NSW 2308 (Australia); Patra, Ashok K. [Indian Council of Agricultural Research (ICAR), Indian Institute of Soil Science, Bhopal (India); Naidu, Ravi, E-mail: ravi.naidu@newcastle.edu.au [Cooperative Research Centre for Contamination Assessment and Remediation of the Environment (CRC CARE), ACT Building, University of Newcastle, Callaghan, NSW 2308 (Australia); Global Centre for Environmental Remediation (GCER), Faculty of Science and Information Technology, University of Newcastle, Callaghan, NSW 2308 (Australia)

    2016-04-15

    Co-contamination of soil and water with polycyclic aromatic hydrocarbon (PAH) and heavy metals makes biodegradation of the former extremely challenging. Modified clay-modulated microbial degradation provides a novel insight in addressing this issue. This study was conducted to evaluate the growth and phenanthrene degradation performance of Mycobacterium gilvum VF1 in the presence of a palmitic acid (PA)-grafted Arquad® 2HT-75-based organobentonite in cadmium (Cd)-phenanthrene co-contaminated water. The PA-grafted organobentonite (ABP) adsorbed a slightly greater quantity of Cd than bentonite at up to 30 mg L{sup −1} metal concentration, but its highly negative surface charge imparted by carboxylic groups indicated the potential of being a significantly superior adsorbent of Cd at higher metal concentrations. In systems co-contained with Cd (5 and 10 mg L{sup −1}), the Arquad® 2HT-75-modified bentonite (AB) and PA-grafted organobentonite (ABP) resulted in a significantly higher (72–78%) degradation of phenanthrene than bentonite (62%) by the bacterium. The growth and proliferation of bacteria were supported by ABP which not only eliminated Cd toxicity through adsorption but also created a congenial microenvironment for bacterial survival. The macromolecules produced during ABP–bacteria interaction could form a stable clay-bacterial cluster by overcoming the electrostatic repulsion among individual components. Findings of this study provide new insights for designing clay modulated PAH bioremediation technologies in mixed-contaminated water and soil. - Highlights: • Surface tailored organobentonite synthesised and characterised • Modified clay adsorbs Cd and reduces toxicity to Mycobacterium gilvum. • It creates congenial microenvironment for bacterial survival. • It enhances phenanthrene biodegradation in metal co-contaminated condition.

  7. Visible-light system for detecting doxorubicin contamination on skin and surfaces.

    Science.gov (United States)

    Van Raalte, J; Rice, C; Moss, C E

    1990-05-01

    A portable system that uses fluorescence stimulated by visible light to identify doxorubicin contamination on skin and surfaces was studied. When activated by violet-blue light in the 465-nm range, doxorubicin fluoresces, emitting orange-red light in the 580-nm range. The light source to stimulate fluorescence was a slide projector with a filter to selectively pass short-wave (blue) visible light. Fluorescence was both observed visually with viewing spectacles and photographed. Solutions of doxorubicin in sterile 0.9% sodium chloride injection were prepared in nine standard concentrations ranging from 2 to 0.001 mg/mL. Droplets of each admixture were placed on stainless steel, laboratory coat cloth, pieces of latex examination glove, bench-top absorbent padding, and other materials on which antineoplastics might spill or leak. These materials then were stored for up to eight weeks and photographed weekly. The relative ability of water, household bleach, hydrogen peroxide solution, and soap solution to deactivate doxorubicin was also measured. Finally, this system was used to inspect the antineoplastic-drug preparation and administration areas of three outpatient cancer clinics for doxorubicin contamination. Doxorubicin fluorescence was easily detectable with viewing spectacles when a slide projector was used as the light source. The photographic method was sensitive for doxorubicin concentrations from 2.0 to 0.001 mg/mL. Immersion of study materials in bleach for one minute eliminated detectable fluorescence. Doxorubicin contamination is detectable for at least eight weeks in the ambient environment. Probable doxorubicin contamination was detected in two of the three clinics surveyed. A safe, portable system that uses fluorescence stimulated by visible light is a sensitive method for detecting doxorubicin on skin and surfaces.

  8. Measurement of surface contamination by certain antineoplastic drugs using high-performance liquid chromatography: applications in occupational hygiene investigations in hospital environments.

    Science.gov (United States)

    Rubino, F M; Floridia, L; Pietropaolo, A M; Tavazzani, M; Colombi, A

    1999-01-01

    Within the context of continuing interest in occupational hygiene of hospitals as workplaces, the authors report the results of a preliminary study on surface contamination by certain antineoplastic drugs (ANDs), recently performed in eight cancer departments of two large general hospitals in Milan, Italy. Since reliable quantitative information on the exposure levels to individual drugs is mandatory to establish a strong interpretative framework for correctly assessing the health risks associated with manipulation of ANDs and rationally advise intervention priorities for exposure abatement, two automated analytical methods were set up using reverse-phase high-performance liquid chromatography for the measurement of contamination by 1) methotrexate (MTX) and 2) the three most important nucleoside analogue antineoplastic drugs (5-fluorouracil 5FU, Cytarabin CYA, Gemcytabin GCA) on surfaces such as those of preparation hoods and work-benches in the pharmacies of cancer wards. The methods are characterized by short analysis time (7 min) under isocratic conditions, by the use of a mobile phase with a minimal content of organic solvent and by high sensitivity, adequate to detect surface contamination in the 5-10 micrograms/m2 range. To exemplify the performance of the analytical methods in the assessment of contamination levels from the target analyte ANDs, data are reported on the contamination levels measured on various surfaces (such as on handles, floor surfaces and window panes, even far from the preparation hood). Analyte concentrations corresponding to 0.8-1.5 micrograms of 5FU were measured on telephones, 0.85-28 micrograms/m2 of CYA were measured on tables, 1.2-1150 micrograms/m2 of GCA on furniture and floors. Spillage fractions between 1-5% of the used ANDs (daily use 5FU 7-13 g; CYA 0.1-7.1 g; GCA 0.2-5 g) were measured on the disposable polythene-backed paper cover sheet of the preparation hood.

  9. Clostridium difficile from food and surface samples in a Belgian nursing home: an unlikely source of contamination.

    Science.gov (United States)

    Rodriguez, C; Korsak, N; Taminiau, B; Avesani, V; Van Broeck, J; Brach, P; Delmée, M; Daube, G

    2015-04-01

    This study investigates the contamination of foods and surfaces with Clostridium difficile in a single nursing home. C. difficile PCR-ribotype 078 was found in one food sample and in none of the tested surfaces. These results indicate that food and surfaces are an unlikely source of C. difficile infection in this setting. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Integrated modelling for assessing the risk of groundwater contaminants to human health and surface water ecosystems

    DEFF Research Database (Denmark)

    McKnight, Ursula S.; Rasmussen, Jes; Funder, Simon G.

    2010-01-01

    for evaluating the impact of a TCE groundwater plume, located in an area with protected drinking water interests, to human health and surface water ecosystems. This is accomplished by coupling the system dynamicsbased decision support system CARO-Plus to the aquatic ecosystem model AQUATOX via an analytical......The practical implementation of the European Water Framework Directive has resulted in an increased focus on the groundwater-surface water interaction zone. A gap exists with respect to preliminary assessment methodologies that are capable of evaluating and prioritising point sources...... volatilisation model for the stream. The model is tested on a Danish case study involving a 750 m long TCE groundwater plume discharging into a stream. The initial modelling results indicate that TCE contaminant plumes with μgL-1 concentrations entering surface water systems do not pose a significant risk...

  11. Contamination by urban superficial runoff: accumulated heavy metals on a road surface

    Directory of Open Access Journals (Sweden)

    Carlos Alfonso Zafra Mejía

    2007-01-01

    Full Text Available Studying the behaviour of accumulated contamination on urban surfaces is important in designing control methods minimising the impacts of surface runoff on the environment. This paper presents data regarding the sediment collected on the surface of an urban road in the city of Torrelavega in northern Spain during a period of 65 days during which 132 samples were collected. Two types of sediment collection samples were obtained: vacuumed dry samples (free load and those swept up following vacuuming (fixed load. The results showed that heavy metal concentration in the collected sediment (Pb, Zn, Cu and Cd was inversely proportional to particle diameter. High heavy metal concentrations were found in the smaller fraction (63 pm. Regression equations were calculated for heavy metal concentration regarding particle diameter. Large heavy metal loads were found in the larger fraction (125 pm. The results provide information for analysing runoff water quality in urban areas and designing treatment strategies.

  12. Effectiveness of disinfection with alcohol 70% (w/v of contaminated surfaces not previously cleaned

    Directory of Open Access Journals (Sweden)

    Maurício Uchikawa Graziano

    2013-04-01

    Full Text Available OBJECTIVE: To evaluate the disinfectant effectiveness of alcohol 70% (w/v using friction, without previous cleaning, on work surfaces, as a concurrent disinfecting procedure in Health Services. METHOD: An experimental, randomized and single-blinded laboratory study was undertaken. The samples were enamelled surfaces, intentionally contaminated with Serratia marcescens microorganisms ATCC 14756 106 CFU/mL with 10% of human saliva added, and were submitted to the procedure of disinfection WITHOUT previous cleaning. The results were compared to disinfection preceded by cleaning. RESULTS: There was a reduction of six logarithms of the initial microbial population, equal in the groups WITH and WITHOUT previous cleaning (p=0.440 and a residual microbial load ≤ 102 CFU. CONCLUSION: The research demonstrated the acceptability of the practice evaluated, bringing an important response to the area of health, in particular to Nursing, which most undertakes procedures of concurrent cleaning /disinfecting of these work surfaces.

  13. Effectiveness of disinfection with alcohol 70% (w/v of contaminated surfaces not previously cleaned

    Directory of Open Access Journals (Sweden)

    Maurício Uchikawa Graziano

    Full Text Available OBJECTIVE: To evaluate the disinfectant effectiveness of alcohol 70% (w/v using friction, without previous cleaning, on work surfaces, as a concurrent disinfecting procedure in Health Services. METHOD: An experimental, randomized and single-blinded laboratory study was undertaken. The samples were enamelled surfaces, intentionally contaminated with Serratia marcescens microorganisms ATCC 14756 106 CFU/mL with 10% of human saliva added, and were submitted to the procedure of disinfection WITHOUT previous cleaning. The results were compared to disinfection preceded by cleaning. RESULTS: There was a reduction of six logarithms of the initial microbial population, equal in the groups WITH and WITHOUT previous cleaning (p=0.440 and a residual microbial load ≤ 102 CFU. CONCLUSION: The research demonstrated the acceptability of the practice evaluated, bringing an important response to the area of health, in particular to Nursing, which most undertakes procedures of concurrent cleaning /disinfecting of these work surfaces.

  14. Geochemical baseline level and function and contamination of phosphorus in Liao River Watershed sediments of China.

    Science.gov (United States)

    Liu, Shaoqing; Wang, Jing; Lin, Chunye; He, Mengchang; Liu, Xitao

    2013-10-15

    The quantitative assessment of P contamination in sediments is a challenge due to sediment heterogeneity and the lacking of geochemical background or baseline levels. In this study, a procedure was proposed to determine the average P background level and P geochemical baseline level (GBL) and develop P geochemical baseline functions (GBF) for riverbed sediments of the Liao River Watershed (LRW). The LRW has two river systems - the Liao River System (LRS) and the Daliao River System (DRS). Eighty-eight samples were collected and analyzed for P, Al, Fe, Ca, organic matter, pH, and texture. The results show that Fe can be used as a better particle-size proxy to construct the GBF of P (P (mg/kg) = 39.98 + 166.19 × Fe (%), R(2) = 0.835, n = 66). The GBL of P was 675 mg/kg, while the average background level of P was 355 mg/kg. Noting that many large cities are located in the DRS watershed, most of the contaminated sites were located within the DRS and the riverbed sediments were more contaminated by P in the DRS watershed than in the LRS watershed. The geochemical background and baseline information of P are of great importance in managing P levels within the LRW. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Optical Interferometry with Flexible Coherent Fiber Bundle for Measuring Deposits or Contamination on Surfaces and Inside Tubes

    Data.gov (United States)

    National Aeronautics and Space Administration — A new measuring/cleaning method for closed surfaces (pipes) applicable to removing contaminants (oil films, fungus, rust) from NASA instruments and spacecraft is...

  16. Radioactive contamination of foodstuffs: determination of permissible levels; Contamination radioactive des denrees alimentaires: determination des niveaux admissibles

    Energy Technology Data Exchange (ETDEWEB)

    Ledermann, S [Commissariat a l' Energie Atomique, Fontenay- aux-Roses (France). Centre d' Etudes Nucleaires

    1965-07-01

    In a latent air-soil contamination situation, the population would receive 80 per cent of its contamination through foodstuffs. The supervision of this food poses many problems: sampling, radionuclide dosages, etc. It is also necessary to estimate the maximum permissible concentration of radionuclides in foodstuffs, once the maximum exposure limit for the human body has been fixed. The passage of this level to the maximum concentrations is not simple since a) each radionuclide has its own particular effect on the body; b) their concentrations vary from one foodstuff to another, and c) the average amounts of foodstuffs vary from one population to another. Two methods are given here for estimating the maximum permissible concentrations in foodstuffs, together with the first diets likely to become critical when several of them are to be considered simultaneously. The results depend on the way in which the present situation can change to become critical. This evolutionary path can only be estimated approximately. Two methods are therefore given for studying the sensitivity of the results. As an example, a numerical application of these methods using data actually available is given. The data used is naturally incomplete and this will always be true. This application test indicates however two fields in which an improvement is absolutely necessary. 1 - The obtention of multiple observations (simultaneous dosage of at least 2 radionuclides in the same foodstuff, and simultaneous dosage of at least two foodstuffs for the same radionuclide); this assumes a combined effort by the various organisms; 2 - The reaching of an agreement on the dosage methods used by the various organisms since the results actually available are not comparable. (authors) [French] Dans une situation de contamination air-sol latente, la contamination des populations se ferait a 80 pour cent par l'alimentation. Surveiller cette alimentation pose des problemes complexes: echantillonnage, dosage des

  17. 131I levels in cow's milk following ingestion of contaminated alfalfa or sudan grass

    International Nuclear Information System (INIS)

    Black, S.C.; Stanley, R.E.; Barth, D.S.

    1975-08-01

    A dry aerosol, consisting of submicrometer diatomaceous earth particles tagged with 131 I, was released over two different types of growing forage (alfalfa and Sudan grass) at the Experimental Dairy Farm on the Nevada Test Site. Following deposition of the aerosol, the two forage types were chopped and fed to different groups of lactating dairy cows. The dual objectives of the study were to evaluate the relationship of 131 I secretion in milk to the ingestion of different types of contaminated forage and to obtain a further indication of the possible influence on milk radioiodine levels of changing the particle size of the contaminant. The ratios of the peak activity concentrations measured in the milk to the peak activity concentrations in the forage were computed to be 0.0145 for the cows fed contaminated alfalfa and 0.0082 for those fed contaminated Sudan grass. Comparison of the results from this study with those from earlier studies indicates the major effect on activity levels in the milk can be related to forage type. Ingestion of Sudan grass by the cow reduces the transfer of radioiodine to milk by one half compared to ingestion of alfalfa. (U.S.)

  18. Current levels and trends of radioactive contamination of aquatic ecosystem components in the Chernobyl exclusion zone

    Energy Technology Data Exchange (ETDEWEB)

    Gudkov, Dmitri I.; Kaglyan, Alexander Ye.; Ganzha, Kristina D.; Klenus, Vasiliy G. [Institute of Hydrobiology, Geroyev Stalingrada Ave. 12, UA-04210 Kiev (Ukraine); Kireev, Sergey I.; Nazarov, Alexander B. [Chernobyl Specialized Enterprise, Radyanska Str. 70, UA-07270 Chernobyl (Ukraine)

    2014-07-01

    The current radiation level and its composition in aquatic ecosystems within the Chernobyl exclusion zone (ChEZ) are conditioned, above all things, by the amount of radioactive matters released as aerosols on a water surface and adjacent territories during the period of the active phase of the accident from destroyed of the Chernobyl NPP in 1986, and also by intensity and duration of the second processes of radionuclides washout from the catchment areas and hydrodynamic processes of their transport outside of water bodies. During last 10-15 years in the soils of the ChEZ the tendency of increase of yield of the mobile bioavailable forms of radionuclides, which released into hydrological systems with surface and ground waters or localized in the closed water systems, where quickly involving in the biotic cycle is marked. On the example of lakes of the Krasnensky flood plain of the Pripyat River, which is one of the most contaminated by radionuclides territory of the ChEZ, was determined that the basic amount of radionuclides in lake ecosystem is deposited in the bottom sediments: {sup 90}Sr - 89-95%, {sup 137}Cs - 99%, transuranium elements (TUE) {sup 238}Pu, {sup 239+240}Pu and {sup 241}Am - almost 100% of the total radionuclide amount in ecosystem. The increased migration activity of {sup 90}Sr determines its more high quantity in water (4-10%) on comparison with {sup 137}Cs (0.5-0.6%) and TUE (0.03-0.04%) and, opposite, less - in seston (0.15-0.16%) on comparison with {sup 137}Cs (0.25-0.30%). The value of {sup 90}Sr in biotic component amounts 0.25-0.61%, {sup 137}Cs - 0.14-0.47% and TUE - 0.07-0.16% of the total quantity in ecosystem. The gradual decline of radionuclide specific activity is a dominant tendency in the dynamics of {sup 137}Cs and {sup 90}Sr in water and aquatic biota of the majority of reservoirs and water flow in the ChEZ. The exception is water bodies, located on the dammed territories of the Krasnensky flood plain, where at the proceeding

  19. Comparative evaluations of surface contamination detectors calibration with radioactive sources - used in the Goiania accident, and standard sources

    International Nuclear Information System (INIS)

    Becker, P.H.B.; Marecha, M.H.H.

    1997-01-01

    The construction of Cs-137 standard flat sources for calibration of surface contamination detectors, used in the Goiania accident in 1987, is described and the procedures adopted are reported. At that time, standard sources were not available. Nowadays the Instituto de Radioprotecao e Dosimetria has standard sources acquired from Amersham which are used as calibration standards for surface contamination detectors. Comparative evaluations between the standard flat sources constructed for the accident and the calibrated ones are presented

  20. Assessment of hyporheic zone, flood-plain, soil-gas, soil, and surface-water contamination at the Old Incinerator Area, Fort Gordon, Georgia, 2009-2010

    Science.gov (United States)

    Guimaraes, Wladmir B.; Falls, W. Fred; Caldwell, Andral W.; Ratliff, W. Hagan; Wellborn, John B.; Landmeyer, James E.

    2011-01-01

    The U.S. Geological Survey, in cooperation with the U.S. Department of the Army Environmental and Natural Resources Management Office of the U.S. Army Signal Center and Fort Gordon, Georgia, assessed the hyporheic zone, flood plain, soil gas, soil, and surface-water for contaminants at the Old Incinerator Area at Fort Gordon, from October 2009 to September 2010. The assessment included the detection of organic contaminants in the hyporheic zone, flood plain, soil gas, and surface water. In addition, the organic contaminant assessment included the analysis of explosives and chemical agents in selected areas. Inorganic contaminants were assessed in soil and surface-water samples. The assessment was conducted to provide environmental contamination data to the U.S. Army at Fort Gordon pursuant to requirements of the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. Total petroleum hydrocarbons were detected above the method detection level in all 13 samplers deployed in the hyporheic zone and flood plain of an unnamed tributary to Spirit Creek. The combined concentrations of benzene, toluene, ethylbenzene, and total xylene were detected at 3 of the 13 samplers. Other organic compounds detected in one sampler included octane and trichloroethylene. In the passive soil-gas survey, 28 of the 60 samplers detected total petroleum hydrocarbons above the method detection level. Additionally, 11 of the 60 samplers detected the combined masses of benzene, toluene, ethylbenzene, and total xylene above the method detection level. Other compounds detected above the method detection level in the passive soil-gas survey included octane, trimethylbenzene, perchlorethylene, and chloroform. Subsequent to the passive soil-gas survey, six areas determined to have relatively high contaminant mass were selected, and soil-gas samplers were deployed, collected, and analyzed for explosives and chemical agents. No explosives or chemical agents were detected above

  1. A Level Set Discontinuous Galerkin Method for Free Surface Flows

    DEFF Research Database (Denmark)

    Grooss, Jesper; Hesthaven, Jan

    2006-01-01

    We present a discontinuous Galerkin method on a fully unstructured grid for the modeling of unsteady incompressible fluid flows with free surfaces. The surface is modeled by embedding and represented by a levelset. We discuss the discretization of the flow equations and the level set equation...

  2. Evaluation of the levels of phthalate ester plasticizers in surface ...

    African Journals Online (AJOL)

    Evaluation of the levels of phthalate ester plasticizers in surface water of Ethiope ... Gas chromatography (GC) coupled with mass spectrometer (MS) was used to ... with their common use in plastic materials and other industrial chemicals.

  3. Purification of fuel and nitrate contaminated ground water using a free water surface constructed wetland plant

    Energy Technology Data Exchange (ETDEWEB)

    Machate, T.; Heuermann, E.; Schramm, K.W.; Kettrup, A.

    1999-10-01

    Contaminated ground water from a former coke plant site was purified in a free water surface (FWS) constructed wetland plant during a 3-mo short-term experiment. The pilot plant (total surface area 27 m{sup 2}) was filled with a 1 m thick lava-gravel substrate planted with cattail (Typha spp.) and bulrush (Scirpus lacustrls). Major contaminants were low to moderate concentrations of polycyclic aromatic hydrocarbons, BTEX, nitrate, and nitrite. The wetland was dosed at hydraulic loading rates of q{sub A} = 4.8 and 9.6 cm d{sup {minus}1} with a hydraulic residence time (HRT) of 13.7 and 6.8 d. The surface removal rates of PAH were between 98.8 and 1914 mg m{sup {minus}2} d{sup {minus}1}. Efficiency was always {gt}99%. Extraction of lava gravel showed that approx. 0.4% of the applied PAH were retained on the substratum. The ratio of {Sigma}2,3-ring PAH and {Sigma}4,5,6-ring PAH showed a shift from 1:0.11 in water to 1:2.5 in lava. The removal of BTEX was {gt}99%, but might be in part due to volatilization. The efficiency in the removal of nitrate was 91% and of nitrite was 97%. Purification performance was not influenced by hydraulic loading rates or after die-back of the macrophytes.

  4. Removal of carbon contaminations by RF plasma generated reactive species and subsequent effects on optical surface

    Energy Technology Data Exchange (ETDEWEB)

    Yadav, P. K., E-mail: praveenyadav@rrcat.gov.in; Rai, S. K.; Modi, M. H.; Nayak, M.; Lodha, G. S. [Indus Synchrotron Utilization Division, Raja Ramanna Centre for Advanced Technology, Indore-452013 (India); Kumar, M.; Chakera, J. A.; Naik, P. A. [Laser Plasma Laboratory, Laser Plasma Division, Raja Ramanna Centre for Advanced Technology, Indore-452013 (India)

    2015-06-24

    Carbon contamination on optical elements is a serious issue in synchrotron beam lines for several decades. The basic mechanism of carbon deposition on optics and cleaning strategies are not fully understood. Carbon growth mechanism and optimized cleaning procedures are worldwide under development stage. Optimized RF plasma cleaning is considered an active remedy for the same. In present study carbon contaminated optical test surfaces (carbon capped tungsten thin film) are exposed for 30 minutes to four different gases, rf plasma at constant power and constant dynamic pressure. Structural characterization (thickness, roughness and density) of virgin samples and plasma exposed samples was done by soft x-ray (λ=80 Å) reflectivity measurements at Indus-1 reflectivity beam line. Different gas plasma removes carbon with different rate (0.4 to 0.65 nm /min). A thin layer 2 to 9 nm of different roughness and density is observed at the top surface of tungsten film. Ar gas plasma is found more suitable for cleaning of tungsten surface.

  5. Individual, population and community level effects of subtle anthropogenic contamination in estuarine meiobenthos

    International Nuclear Information System (INIS)

    Rubal, Marcos; Guilhermino, Lucia M.; Medina, Matias H.

    2009-01-01

    The study presented here searched for the level of taxonomic resolution required to detect the effects of low-level chronic pollution on estuarine meiobenthic communities. Meiofauna from two sites, with special attention to harpacticoid copepods, was analysed at different taxonomic levels of aggregation using uni- and multivariate methods. Adaptation processes that could buffer biodiversity disruptions were also considered through the analysis of fitness-related and tolerance traits in the harpacticoid copepod Paronychocamptus nanus. Results showed that uni- and multivariate analyses could be inadequate when assessing subtle anthropogenic contamination. Instead, the assessment of inter-population differences in tolerance to the main source of stress rises as a required procedure if potential effects of this type of contamination are being investigated. Specifically, a 96 h acute toxicity test performed with populations from the affected site appears as a faster and reliable general tool to assess impacts of low-level chronic pollution in estuaries. - Tolerance of local populations as a reliable tool to assess impacts of subtle anthropogenic contamination in estuaries.

  6. Individual, population and community level effects of subtle anthropogenic contamination in estuarine meiobenthos

    Energy Technology Data Exchange (ETDEWEB)

    Rubal, Marcos [CIIMAR/CIMAR-LA - Centro Interdisciplinar de Investigacao Marinha e Ambiental, Universidade do Porto, Laboratorio de Ecotoxicologia, Rua dos Bragas 289, 4050-123 Porto (Portugal); Guilhermino, Lucia M. [CIIMAR/CIMAR-LA - Centro Interdisciplinar de Investigacao Marinha e Ambiental, Universidade do Porto, Laboratorio de Ecotoxicologia, Rua dos Bragas 289, 4050-123 Porto (Portugal); ICBAS - Instituto de Ciencias Biomedicas de Abel Salazar, Departamento de Estudos de Populacoes, Laboratorio de Ecotoxicologia, Universidade do Porto, Lg. Prof. Abel Salazar 2, 4099-003 Porto (Portugal); Medina, Matias H., E-mail: matias.medina@avs-chile.c [AVS Chile SA, Imperial 0655, Off. 3A, Puerto Varas (Chile); Centro i-mar, Universidad de Los Lagos, Camino Chinquihue km 6, Puerto Montt (Chile)

    2009-10-15

    The study presented here searched for the level of taxonomic resolution required to detect the effects of low-level chronic pollution on estuarine meiobenthic communities. Meiofauna from two sites, with special attention to harpacticoid copepods, was analysed at different taxonomic levels of aggregation using uni- and multivariate methods. Adaptation processes that could buffer biodiversity disruptions were also considered through the analysis of fitness-related and tolerance traits in the harpacticoid copepod Paronychocamptus nanus. Results showed that uni- and multivariate analyses could be inadequate when assessing subtle anthropogenic contamination. Instead, the assessment of inter-population differences in tolerance to the main source of stress rises as a required procedure if potential effects of this type of contamination are being investigated. Specifically, a 96 h acute toxicity test performed with populations from the affected site appears as a faster and reliable general tool to assess impacts of low-level chronic pollution in estuaries. - Tolerance of local populations as a reliable tool to assess impacts of subtle anthropogenic contamination in estuaries.

  7. The cost and benefit analysis of a contaminated area remediation: case study of dose level selection

    International Nuclear Information System (INIS)

    Lauria, D.C.

    2006-01-01

    In recent years there has been an increasing awareness of the radiological impact of non-nuclear industries that extract and/or process ores and minerals containing naturally occurring radioactive material (NORM). Without radiological rules, these industrial activities may result in significant radioactive contamination of installations and sites. Depending on the potential hazardous to the environment and public health, the radioactive contaminated sites may require remediation. The extent of the site cleanup is a function of the size, localization, complexity, potential risks and on possible future uses envisioned for the site. Since worker and public health, public anxiety and economics factors are involved; the selection of an appropriate dose level can be quite complicated. This paper discusses the selection of a dose level criterion to remedy a site, which was contaminated by wastes from monazite processing. The site is located in the Sao Paulo city; the most densely populated Brazilian City. In its 60,000 square meters of area, a preliminary survey showed contaminated zones covering an area of 6,500 square meters. In some places, contamination was found below the superficial layer of the soil, being the radionuclide vertical distribution not uniform. The 228 Ra soil activity concentration reached values up to 33,000 Bq/kg while those for 226 Ra reached values up to 6,700 Bq/kg. Based on pathway analysis model and considering both the current land use and a hypothetical residential scenario, the residual contamination levels of radionuclides in soil have been derived for dose values of 10 mSv/y (dose level for intervention), 5 mSv/y, 3 mSv/y, 1 mSv/y (dose limit for practices) and 0.3 mSv/y (dose constraint for practices). An optimized value o f annual dose of about 5 mSv/y would be a good option for intervention level, but taking into account the public concern and anxiety, the site location and size, and the remediation costs, it is suggested the

  8. The cost and benefit analysis of a contaminated area remediation: case study of dose level selection

    Energy Technology Data Exchange (ETDEWEB)

    Lauria, D.C. [Instituto de Radioproteccion e Dosimetria- IRD/CNEN, Av. Salvador Allende s/n, Barra de Tijuca, Rio de Janeiro- RJ (Brazil)]. e-mail: dejanira@ird.gov.br

    2006-07-01

    In recent years there has been an increasing awareness of the radiological impact of non-nuclear industries that extract and/or process ores and minerals containing naturally occurring radioactive material (NORM). Without radiological rules, these industrial activities may result in significant radioactive contamination of installations and sites. Depending on the potential hazardous to the environment and public health, the radioactive contaminated sites may require remediation. The extent of the site cleanup is a function of the size, localization, complexity, potential risks and on possible future uses envisioned for the site. Since worker and public health, public anxiety and economics factors are involved; the selection of an appropriate dose level can be quite complicated. This paper discusses the selection of a dose level criterion to remedy a site, which was contaminated by wastes from monazite processing. The site is located in the Sao Paulo city; the most densely populated Brazilian City. In its 60,000 square meters of area, a preliminary survey showed contaminated zones covering an area of 6,500 square meters. In some places, contamination was found below the superficial layer of the soil, being the radionuclide vertical distribution not uniform. The {sup 228} Ra soil activity concentration reached values up to 33,000 Bq/kg while those for {sup 226} Ra reached values up to 6,700 Bq/kg. Based on pathway analysis model and considering both the current land use and a hypothetical residential scenario, the residual contamination levels of radionuclides in soil have been derived for dose values of 10 mSv/y (dose level for intervention), 5 mSv/y, 3 mSv/y, 1 mSv/y (dose limit for practices) and 0.3 mSv/y (dose constraint for practices). An optimized value o f annual dose of about 5 mSv/y would be a good option for intervention level, but taking into account the public concern and anxiety, the site location and size, and the remediation costs, it is suggested

  9. Laser assisted decontamination of metal surface: Evidence of increased surface absorptivity due to field enhancement caused by transparent/semi-transparent contaminant particulates

    International Nuclear Information System (INIS)

    Nilaya, J. Padma; Biswas, Dhruba J.

    2010-01-01

    Small signal absorption measurements of the incident coherent radiation by the metal surface have revealed an increase in the absorption by the surface in presence of transparent/semi-transparent particulates on it. This effect, identified as field enhanced surface absorption, has been found to increase with reduction in the average particulate size. Consequently higher laser assisted removal efficiency of contamination from a metal surface has been observed for smaller contaminant particulates. These measurements have been carried out utilizing coherent radiations of two different wavelengths so chosen that for one the particulates are totally transparent while for the other they are partially transparent.

  10. Levels for the specific activity at disposing low-level contaminated municipal wastes

    International Nuclear Information System (INIS)

    Poschner, J.; Schaller, G.

    1993-12-01

    Using radioecological models, nuclide-specific ''basic values'' were established for the specific activity of radioactive contaminated waste. These basic values were determined in order to avoid dose equivalents of more than 10 μSv/a (de minimis concept) when disposing the waste in conventional waste deposits or burning it in incineration plants. The basic values vary within 16 orders of magnitude, ranging between 4.3E-02 Bq/g for Cm-250 and 2.2E+14 Bq/g for Po-212. About 82% of the basic values are between 1 Bq/g und 1000 Bq/g. The critical exposure for most of the radionuclides is that from direct radiation or inhalation at the slag-deposit. For 54% of the radionuclides the basic value for the specific activity of waste is lower at least by a factor of 10 than the 10 -4 -fold value per gram of the release limit (German Radiation Protection Ordinance). Appropriate nuclide-specific and dose-related limits were derived from these basic values. The respective limits are ranging between 1E-01 Bq/g and 1E+07 Bq/g. About 95% of the limits are between 1 Bq/g and 1000 Bq/g. (orig./HP) [de

  11. Levels for the specific activity at disposing low-level contaminated municipal wastes

    International Nuclear Information System (INIS)

    Poschner, J.; Schaller, G.

    1995-01-01

    Using radioecological models, nuclide specific values were calculated for the specific activity of low contaminated radioactive waste, which is disposed in conventional waste deposits or burned in incineration plants. The calculation of these values is based on a limit of 10 μSv effective dose in one year, i.e. effective dose possibly resulting from waste disposal or burning should not exceed a 'de-minimis'-value of some 10 μSv per year. The applied radioecological models describe exposure of the public by direct radiation, inhalation and ingestion for the operational period of a deposit or an incineration plant, but also cover post-operational scenarios, collecting and sorting of waste and road accidents of the waste-truck. Referring to the dose limit of 10 μSv/a, a value for the specific activity of waste was calculated for each scenario and each radionuclide considered. The smallest of these values for a radionuclide, the 'basic value' was rounded to a 'reference value'. For about 600 radionuclides reference values were derived. About 90% of the reference values are ranging between 1 and 1 000 Bq/g. For about 90% of the radionuclides direct radiation or inhalation at the deposit proved to be the critical path of exposure. (orig.) [de

  12. Reduction of bacterial surface contamination in the hospital environment by application of a new product with persistent effect.

    Science.gov (United States)

    Hedin, G; Rynbäck, J; Loré, B

    2010-06-01

    The benefit of routine surface disinfection in hospitals has been discussed. In this study we have investigated a new product, Appeartex. After application on surfaces a remnant effect is achieved due to the positive charge of the active molecule. We studied the persistent effect of Appeartex one day after application in both an experimental study in the laboratory and a field study in a hospital ward. Surfaces of bedside tables were investigated. In the experimental study, large inocula of >or=10(6)cfu of S. aureus or enterococci were inoculated on to well-defined areas which had been treated/not treated with Appeartex. One hour later, samples were taken with a swab rinse technique. A reduction in the number of viable bacteria in the magnitude 10-10(3) cfu was seen due to the effect of Appeartex. In the field study the effect on naturally occurring low level contamination was studied. Defined surfaces on bedside tables used by patients were treated/not treated with Appeartex. One day later, samples were taken with contact agar plates and with a new swab method using two sequential nylon flocked swabs. Significantly fewer bacteria were found on Appeartex-treated surfaces compared with untreated surfaces. The median counts on Appeartex-treated surfaces were 10 cfu/50 cm(2), and on untreated surfaces 20 cfu/50 cm(2). There was no significant difference in the number of bacteria found by culture of samples taken with the contact agar method compared with samples taken using the nylon flocked swab method. (c) 2010 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

  13. Application of autonomous robotics to surveillance of waste storage containers for radioactive surface contamination

    International Nuclear Information System (INIS)

    Sweeney, F.J.; Beckerman, M.; Butler, P.L.; Jones, J.P.; Reister, D.B.

    1991-01-01

    This paper describes a proof-of-principal demonstration performed with the HERMIES-III mobile robot to automate the inspection of waste storage drums for radioactive surface contamination and thereby reduce the human burden of operating a robot and worker exposure to potentially hazardous environments. Software and hardware for the demonstration were developed by a team consisting of Oak Ridge National Laboratory, and the Universities of Florida, Michigan, Tennessee, and Texas. Robot navigation, machine vision, manipulator control, parallel processing and human-machine interface techniques developed by the team were demonstrated utilizing advanced computer architectures. The demonstration consists of over 100,000 lines of computer code executing on nine computers

  14. Comparison of surface contamination monitors for in vivo measurement of {sup 131}I in thyroid

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, S.M.; Dantas, A.L.A.; Dantas, B.M., E-mail: salomao.marques@ymail.com [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    The routine handling of radiopharmaceuticals in nuclear medicine represents a significant risk of internal exposure to the staff. The IAEA recommends the implementation of monitoring plans for all workers subject to a risk of exposures above 1 mSv per year. However, in Brazil, such recommendation is practically unfeasible due to the lack of a sufficient number of qualified internal dosimetry services over the country. This work presents an alternative based on a simple and inexpensive methodology aimed to perform in-vivo monitoring of {sup 131}I in thyroid using portable surface contamination probes. All models evaluated showed suitable sensitivity for such application. (author)

  15. Surface Water Contamination and Los Alamos National Laboratory's Holistic Approach to Mitigation

    International Nuclear Information System (INIS)

    Katzman, D.; Veenis, S.; Reneau, S.

    2009-01-01

    A sediment and contaminant transport mitigation project is being implemented at Los Alamos National Laboratory. This effort is driven by a requirement from State of New Mexico regulators and is also in concert with efforts underway to support a surface-water diversion project by a Santa Fe, NM, public water utility. The effort is being implemented in a large geomorphically and hydrologically complex watershed. Rather than simply attempting to trap sediment in a retention basin, this effort uses a watershed-scale holistic approach with intent to promote watershed healing. (authors)

  16. Ion bombardment induced surface topography modification of clean and contaminated single crystal Cu and Si

    International Nuclear Information System (INIS)

    Lewis, G.W.; Kiriakides, G.; Carter, G.; Nobes, M.J.

    1982-01-01

    Among the several factors which lead to depth resolution deterioration during sputter profiling, surface morphological modification resulting from local differences of sputtering rate can be important. This paper reports the results of direct scanning, electron microscopic studies obtained quasi-dynamically during increasing fluence ion bombardment of the evolution of etch pit structures on Si and Cu, and how such elaboration may be suppressed. It also reports on the elaboration of contaminant-induced cone generation for different ion species bombardment. The influence of such etch pit and cone generation on achievable depth resolution is assessed. (author)

  17. Comparison of surface contamination monitors for in vivo measurement of 131I in thyroid

    International Nuclear Information System (INIS)

    Oliveira, S.M.; Dantas, A.L.A.; Dantas, B.M.

    2015-01-01

    The routine handling of radiopharmaceuticals in nuclear medicine represents a significant risk of internal exposure to the staff. The IAEA recommends the implementation of monitoring plans for all workers subject to a risk of exposures above 1 mSv per year. However, in Brazil, such recommendation is practically unfeasible due to the lack of a sufficient number of qualified internal dosimetry services over the country. This work presents an alternative based on a simple and inexpensive methodology aimed to perform in-vivo monitoring of 131 I in thyroid using portable surface contamination probes. All models evaluated showed suitable sensitivity for such application. (author)

  18. Assessment of PCDD/Fs levels in soil at a contaminated sawmill site in Sweden – A GIS and PCA approach to interpret the contamination pattern and distribution

    International Nuclear Information System (INIS)

    Henriksson, S.; Hagberg, J.; Bäckström, M.; Persson, I.; Lindström, G.

    2013-01-01

    Polychlorinated dibenzo-p-dioxins and polychlorinated dibenzo-p-furans (PCDD/Fs) were analysed in soil from a Swedish sawmill site where chlorophenols (CPs) had been used more than 40 years ago. The most contaminated area at the site was the preservation subarea where the PCDD/F WHO 2005 -TEQ level was 3450 times higher than the current Swedish guideline value of 200 ng TEQ/kg soil for land for industrial use. It was also shown that a fire which destroyed the sawmill might have affected the congener distribution at the concerned areas. To get a broader picture of the contamination both GIS (spatial interpolation analysis) and multivariate data analysis (PCA) were applied to visualize and compare PCDD/F levels as well as congener distributions at different areas at the site. It is shown that GIS and PCA are powerful tools in decisions on future investigations, risk assessments and remediation of contaminated sites. -- Highlights: •GIS and PCA visualize and compare site levels and congener patterns of dioxins. •Subareas were separated by differences in contamination levels and congener patterns. •Fire had a significant effect on the congener distribution at the site. -- The use of geostatistical and multivariate statistical methods are powerful tools to visualize the contamination pattern and distribution at a highly PCDD/Fs-contaminated site

  19. Sampling for Beryllium Surface Contamination using Wet, Dry and Alcohol Wipe Sampling

    Energy Technology Data Exchange (ETDEWEB)

    Kerr, Kent [Central Missouri State Univ., Warrensburg, MO (United States)

    2004-12-01

    This research project was conducted at the National Nuclear Security Administration's Kansas City Plant, operated by Honeywell Federal Manufacturing and Technologies, in conjunction with the Safety Sciences Department of Central Missouri State University, to compare relative removal efficiencies of three wipe sampling techniques currently used at Department of Energy facilities. Efficiencies of removal of beryllium contamination from typical painted surfaces were tested by wipe sampling with dry Whatman 42 filter paper, with water-moistened (Ghost Wipe) materials, and by methanol-moistened wipes. Test plates were prepared using 100 mm X 15 mm Pyrex Petri dishes with interior surfaces spray painted with a bond coat primer. To achieve uniform deposition over the test plate surface, 10 ml aliquots of solution containing 1 beryllium and 0.1 ml of metal working fluid were transferred to the test plates and subsequently evaporated. Metal working fluid was added to simulate the slight oiliness common on surfaces in metal working shops where fugitive oil mist accumulates over time. Sixteen test plates for each wipe method (dry, water, and methanol) were processed and sampled using a modification of wiping patterns recommended by OSHA Method 125G. Laboratory and statistical analysis showed that methanol-moistened wipe sampling removed significantly more (about twice as much) beryllium/oil-film surface contamination as water-moistened wipes (p< 0.001), which removed significantly more (about twice as much) residue as dry wipes (p <0.001). Evidence for beryllium sensitization via skin exposure argues in favor of wipe sampling with wetting agents that provide enhanced residue removal efficiency.

  20. Arsenic levels in the groundwater of Korea and the urinary excretion among contaminated area.

    Science.gov (United States)

    Park, Jung-Duck; Choi, Seong-Jin; Choi, Byung-Sun; Lee, Choong-Ryeol; Kim, Heon; Kim, Yong-Dae; Park, Kyung-Soo; Lee, Young-Jo; Kang, Seojin; Lim, Kyung-Min; Chung, Jin-Ho

    2016-09-01

    Drinking water is a main source of human exposure to arsenic. Hence, the determination of arsenic in groundwater is essential to assess its impact on public health. Here, we report arsenic levels in the groundwater of 722 sites covering all six major provinces of Korea. Water was sampled in two occasions (summer, 722 sites and winter, 636 sites) and the arsenic levels were measured with highly sensitive inductively coupled plasma-mass spectrometry method (limit of detection, 0.1 μg/l) to encompass the current drinking water standard (arsenic in groundwater ranged from 0.1 to 48.4 μg/l. A 88.0-89.0% of sites were 10 μg/l. Notably, urinary arsenic excretion of people around these regions was markedly higher compared with non-contaminated areas (arsenic-contaminated groundwater may contribute to its systemic exposure.

  1. Bioavailability of caesium-137 from chernozem soils with high and low levels of radioactive contamination

    Science.gov (United States)

    Paramonova, Tatiana; Shamshurina, Eugenia; Machaeva, Ekaterina; Belyaev, Vladimir

    2014-05-01

    Bioavailability of Cs-137 in "soil-plant" system of radioactively contaminated terrestrial ecosystems is the most important factor in the understanding of ecological situation. There are many factors affecting the features of Cs-137 biogeochemical cycle: period since an accident, type and intensity of radioactive fallout, general properties of landscape and the specifics of soil and plant covers, etc. In order to evaluate the importance of soil contamination level for the process of Cs-137 translocation from soil to plant the research in forest-steppe areas of Russia with similar natural properties, but contrasting high (Tula region) and low (Kursk region) levels of radioactive Chernobyl fallout (about 25 years after accident) was conducted. Soil cover of both sites is presented by chernozems with bulk density 1.1-1.2 g/cm3, 6-7% humus and neutral pH 6.5-7.2; plant cover under investigation consist of dry and wet meadows with bioproductivity 1.6-2.5 kg/m2 and 85-90% of biomass concentrated underground, that is typical for Russian forest-steppe landscapes. At the same time levels of soil regional contamination with Cs-137 differ by an order - 620-710 Bq/kg (210-250 kBq/m2) in Tula region and 30-55 Bq/kg (10-20 kBq/m2) in Kursk region. At a higher level of soil radioactive contamination specific activity of Cs-137 in vegetation of meadows is noticeably increased (103-160 Bq/kg in Tula region versus 12-14 Bq/kg in Kursk region) with correlation coefficient r 0.87. Increasing of Cs-137 in the underground parts of plants plays a decisive role in this process, while the specific radionuclide's activity in the aboveground parts of different sites is almost invariant (and ubiquitously roots contain 2-5 times more Cs-137 than shoots). The values of transfer factors for Cs-137 (the ratio of the specific Cs-137 activities in the plant tissue and in the soil) at various levels of soil radioactive contamination vary within a relatively narrow range 0.1-0.4, that confirms the

  2. 'Becquerel screening' device to automatically measure activity level of contaminated soil in flexible containers

    International Nuclear Information System (INIS)

    Okada, Hisashi; Yamaguchi, Yoshihisa; Yamamoto, Shuji

    2014-01-01

    Contaminated soil and incineration ash collected during offsite decontamination work following the accident at the Fukushima Daiichi Nuclear Power Station of Tokyo Electric Power Co., Inc. is being stored in flexible containers. These containers are managed taking their activity level into account in accordance with the Decontamination Guidelines issued by the Ministry of the Environment. Toshiba has developed the 'Becquerel Screening' device that can automatically measure the activity level of the contents of each flexible container simply by placing the container on a palette, without the need to take samples for analysis from the container. The Becquerel Screening device is expected to contribute not only to improved operational efficiency but also to reduced exposure of operators to radiation, because it eliminates the need for direct contact with contaminated soil and ash. (author)

  3. Mercury contamination in vicinity of secondary copper smelters in Fuyang, Zhejiang Province, China: Levels and contamination in topsoils

    International Nuclear Information System (INIS)

    Yin Xuebin; Yao Chunxia; Song Jing; Li Zhibo; Zhang Changbo; Qian Wei; Bi De; Li Chenxi; Teng Ying; Wu Longhua; Wan Hongdong; Luo Yongming

    2009-01-01

    In the present study, we aim to investigate the extent of soil contamination by Hg, particularly by anthropogenic Hg, and tentatively estimate the total Hg (Hg T ) accumulation in topsoils (0-15 cm) in Fuyang, Zhejiang Province-a secondary Cu smelter of China. The results show that the levels of soil Hg in the vicinity of the smelters have been substantially elevated following local smelting activities. The spatial distribution of soil Hg in this area reveals a rapid decrease as the distance from the smelter reaches 1.5 km, which is probably due to the quick deposition process of particulate Hg and reactive gaseous Hg emitted from the smelters. The total accumulation of Hg T in the topsoils of the study area of 10.9 km 2 is approximately 365-561 kg and of which 346-543 kg might be contributed by anthropogenic emission alone with an annual emission of 17.3-27.2 kg Hg to the topsoils. - Secondary copper smelters in Fuyang release a considerable amount of mercury into topsoils.

  4. A model to determine the radiological implications of non-fixed radioactive contamination on the surfaces of packages and conveyances

    International Nuclear Information System (INIS)

    Hughes, J.S.; Warner Jones, S.M.; Lizot, M.T.; Perrin, M.L.; Thierfeld, S.; Schroedl, E.; Schwarz, G.; Rawl, R.; Munakata, M.; Hirose, M.

    2004-01-01

    The surfaces of packages and conveyances used to transport radioactive materials can sometimes become contaminated with radioactive material. This usually occurs as a result of the transfer of radioactive material from areas in which these packages and conveyances are handled. This contamination may subsequently be transferred to transport equipment, workers and to areas accessible to the public. This can represent a significant radiation safety issue that requires careful management. The current regulatory limits for non-fixed contamination on packages and conveyances have been in use for over 40 years, and are based on a simple exposure model. However, the bases on which these limits were derived have been subject to changes, as a result of successive revisions of international recommendations. In recognition of this need for a review and analysis of the current contamination limits an IAEA Co-ordinated Research Project (CRP) on the ''Radiological Aspects of Package and Conveyance Non-Fixed Contamination'' was initiated to review the scientific basis for the current regulatory limits for surface contamination. The CRP was also to develop guidance material for evaluating the radiological significance of surface contamination to workers and the public in light of state-of-the-art research, technical developments and current transport practices. The specific objectives of the work undertaken within this multi-national CRP were, in accordance with the terms of reference: To ensure that appropriate models exist for all package types including consideration of the aspects pertinent for assessing and revising a surface contamination model for transport. To collect - where possible - contamination, operational and dosimetric data to ensure modelling consistency. To use models for assessing the limitations and optimisation of radiation doses incurred in transport operations, and to consider preventive methods for package and conveyance contamination

  5. Simple surface foam application enhances bioremediation of oil-contaminated soil in cold conditions.

    Science.gov (United States)

    Jeong, Seung-Woo; Jeong, Jongshin; Kim, Jaisoo

    2015-04-09

    Landfarming of oil-contaminated soil is ineffective at low temperatures, because the number and activity of micro-organisms declines. This study presents a simple and versatile technique for bioremediation of diesel-contaminated soil, which involves spraying foam on the soil surface without additional works such as tilling, or supply of water and air. Surfactant foam containing psychrophilic oil-degrading microbes and nutrients was sprayed twice daily over diesel-contaminated soil at 6 °C. Removal efficiencies in total petroleum hydrocarbon (TPH) at 30 days were 46.3% for landfarming and 73.7% for foam-spraying. The first-order kinetic biodegradation rates for landfarming and foam-spraying were calculated as 0.019 d(-1) and 0.044 d(-1), respectively. Foam acted as an insulating medium, keeping the soil 2 °C warmer than ambient air. Sprayed foam was slowly converted to aqueous solution within 10-12h and infiltrated the soil, providing microbes, nutrients, water, and air for bioaugmentation. Furthermore, surfactant present in the aqueous solution accelerated the dissolution of oil from the soil, resulting in readily biodegradable aqueous form. Significant reductions in hydrocarbon concentration were simultaneously observed in both semi-volatile and non-volatile fractions. As the initial soil TPH concentration increased, the TPH removal rate of the foam-spraying method also increased. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Nickel, Lead and Zinc Contamination in the Surface Sediments of Agh Gel Wetland, Iran

    Directory of Open Access Journals (Sweden)

    Soheil Sobhan Ardakani

    2016-07-01

    Full Text Available Background & Aims of the Study: Due to the increased human activities around the Agh Gel wetland, this study aimed to measured accumulations of heavy metals (Ni, Pb and Zn in the surface sediment samples taken from this wetland. Materials & Methods: Samples were taken from 10 stations and exposed to bulk digestion and chemical partitioning. Finally, Ni, Pb and Zn concentrations were monitored with ICP-OES in the sediments. Also, geo-accumulation index, contamination factor and pollution load index were used to evaluate the magnitude of contaminants in the sediment profile. Results: The results showed, the average of metal concentration in samples (mg kg-1 wet weight were 34.20±3.58 for Ni, 25.37±2.52 for Pb and 127.20±15.21 for Zn, respectively. Therefore, the pattern of metal concentrations in sediment was determined as Zinc>Nickel >Lead. According to the mean I-geo values, sediments' qualities are classified as unpolluted category for Ni and Pb. Also, sediment's quality is classified as unpolluted to moderately polluted for Zn. The CF values for all elements are classified as moderate contamination. The PLI values indicated that metal pollution exists for all sampling stations. Conclusions: The obtained results indicated that the Agh Gel wetland has a potential to threaten by chemical pollutants such as agricultural effluent. So, in order to preserve the environment of the Agh Gel wetland from deterioration, monitoring of water and sediment qualities is recommended periodically.

  7. Effects of industrial processing on essential elements and regulated and emerging contaminant levels in seafood

    DEFF Research Database (Denmark)

    Rasmussen, Rie Romme; Bøge Søndergaard, Annette; Bøknæs, Niels

    2017-01-01

    Mitigation of contaminants in industrial processing was studied for prawns (cooked and peeled), Greenland halibut (cold smoked) and Atlantic salmon (cold smoked and trimmed). Raw prawns had significantly higher cadmium, chromium, iron, selenium and zinc content in autumn than in spring, while...... summer levels typically were intermediate. Peeling raw prawns increased mercury concentration but reduced the concentration of all other elements including inorganic arsenic, total arsenic, chromium, zinc, selenium but especially cadmium, copper and iron (p

  8. Profiling micro-organic contaminants in groundwater using multi-level piezometers

    OpenAIRE

    White, Debbie; Lapworth, Dan; Stuart, Marianne; Williams, Peter

    2015-01-01

    The presence of micro-organic pollutants, including ‘emerging contaminants’ within groundwater is of increasing interest. Robust protocols are required to minimise the introduction of contamination during the sampling process. Below we discuss the sampling protocols used to reduce inputs of plasticisers during the sampling process, as well as the techniques used to characterise the distribution of micro-organic pollutants in the subsurface. In this study multi-level piezometers...

  9. Assessment of heavy metal contamination, levels in topsoil at selected auto-workshops in Accra, Ghana

    International Nuclear Information System (INIS)

    Ziblim, M. Y.

    2015-07-01

    The research was conducted to assess the levels of contamination of heavy metals in the topsoil at selected auto-workshops in Accra to determine the anthropogenic and crustal contributions and the human heath risk associated with them. Soil samples collected from four auto-workshops were analysed using Atomic Absorption Spectrometer. Eleven (11) elements: Co, Fe, Cu, Mn, Cr, As, Hg, Zn, Pb, Ni, and Cd were identified in each sample collected from the auto-workshops. Pollution indices; contamintion factor (Cf) index of geoaccumulation (Igeo) and pollution load index (PLI) were used to assess the contamination levels. It revealed the extent of contamination at the auto-workshops for most of the elements which range from low to considerate contamintion. Lead (Pb) recorded the greatest contamination levels at the auto-electrical location. The results from the index of geoccumulation showed no pollution to highly pollution indicting high variations of pollution levels at different locations. The results of the PLI in almost all locations ranged from moderately to extremely polluted. Noncancer effect on children and adults due to exposure to the topsoil were also estimated with some selected metal elements. The hazard quotient (HQ) evaluation, showed ingestion to be the route of exposure to soil dust that results in a higher risk for heavy metals, followed by dermal contact. The effect due to inhalation of resuspended dust particles through the mouth and nose is relatively low. It was observed that, the auto-workshops are generally polluted with heavy metals and therefore posing ill-health effect to the humans and the environment. (au)

  10. Contamination levels of aflatoxin M1 in bulk raw milk of Chaloos and Ramsar

    Directory of Open Access Journals (Sweden)

    A.R Barami

    2012-02-01

    Full Text Available Aflatoxin M1 (AFM1 appears in milk as a direct result of the ingestion of feed contaminated with aflatoxin B1 by cattle. This study was conducted to investigate the contamination rate of raw milk whit aflatoxin M1 in Chaloos and Ramsar raw milk collection centers. Two hundred bulk raw milk samples were collected during winter (January and February and summer (June and July seasons. The milk samples were analyzed by ELISA method for the presence of AFM1. During the winter, AFM1 was detected in 100% and 59/79% of the bulk raw milk samples in Ramsar and Chaloos, respectively; however, during summer 83/52% and 50/1 of the samples was found as positive in Ramsar and Chaloos, respectively. Furthermore, 45% of Ramsar and 30% of Chaloos bulk milk samples showed higher contamination level of AFM1 than maximum tolerance limit (50 ng/l accepted by National Standard as well as European Union. Although, the difference between the contamination rate in samples obtained during summer and winter seasons was not statistically significantly, (p

  11. Monitoring pesticides residues and contaminants for some leafy vegetables at the market level

    International Nuclear Information System (INIS)

    Ibrahim, A. B. H.

    2004-03-01

    Pesticide residues and contaminants in selected leafy vegetables, namely (lettuce, garden rocket and salad onion) were monitored at market level in Riyadh City in Saudi Arabia, during the period june to july 2001. Fifteen samples of vegetables from the City vegetable market of Riyadh were collected and subjected to multi-pesticide residue detection and analysis by gas chromatography with mass spectrometer and electron capture detectors (GC/MS,ECD). Results of sample extracts analysis showed that the two vegetables of: garden rocket and salad onion contain pesticide residues and contaminants which have no Maximum Residue Limits (MRL) prescribed by Codex Alimentarius Commission (CAC) collaborate with World Health and Food and Agriculture Organizations (WHO/FAO). Whereas lettuce vegetable was found free of any identified pesticide residues or contaminants. Garden rocket was shown to contain dibutyl phthalate (0.04 ppm)-steryl chloride (0.02 ppm) tridecane (0.06 ppm)-hexadecane (0.07 ppm)-BIS (ethylhexyl) phthalate (0.006 ppm) and pyridinium, 1-hexyl chloride (0.01 ppm). The salad onion was found to contain 9-octadecanamide (0.13 ppm)-tridecane (0.15 ppm) and tetradecane (0.16 ppm). There are no established MRL s for these pesticides and contaminants detected in garden rocket and salad onion, although when impacts on human health were reviewed some of them were found probably hazardous. (Author)

  12. Analysis of Radioactivity Contamination Level of Kartini Reactor Efluen Gas to the Environment

    International Nuclear Information System (INIS)

    Suratman; Purwanto; Aminjoyo, S

    1996-01-01

    The analysis of radioactivity contamination level of Kartini reactor efluen gas to the environment has been done from 13-10-'95 until 8-2-'96. The aim of this research is to determine the radioactivity contamination level on the environment resulted from the release of Kartini reactor efluen gas and other facilities at Yogyakarta Nuclear Research Centre through stack. The analysis methods is the student t-test, the first count factor test and the gamma spectrometry. The gas sampling were carried out in the stack reactor, reactor room, environment and in other room for comparison. Efluen gas was sucked through a filter by a high volume vacuum pump. The filter was counted for beta, gamma and alpha activities. The radioactivity contamination level of the efluen gas passing through the stack to the environment was measured between 0.57 - 1.34 Bq/m3, which was equal to the airborne radioactivity in environment between 0.69 - 1.12 Bq/m3. This radioactivity comes from radon daughter, decay products result from the natural uranium and thorium series of the materials of the building

  13. Assessment of levels of bacterial contamination of large wild game meat in Europe.

    Science.gov (United States)

    Membré, Jeanne-Marie; Laroche, Michel; Magras, Catherine

    2011-08-01

    The variations in prevalence and levels of pathogens and fecal contamination indicators in large wild game meat were studied to assess their potential impact on consumers. This analysis was based on hazard analysis, data generation and statistical analysis. A total of 2919 meat samples from three species (red deer, roe deer, wild boar) were collected at French game meat traders' facilities using two sampling protocols. Information was gathered on the types of meat cuts (forequarter or haunch; first sampling protocol) or type of retail-ready meat (stewing meat or roasting meat; second protocol), and also on the meat storage conditions (frozen or chilled), country of origin (eight countries) and shooting season (autumn, winter, spring). The samples were analyzed in both protocols for detection and enumeration of Escherichia coli, coagulase+staphylococci and Clostridium perfringens. In addition, detection and enumeration of thermotolerant coliforms and Listeria monocytogenes were performed for samples collected in the first and second protocols, respectively. The levels of bacterial contamination of the raw meat were determined by performing statistical analysis involving probabilistic techniques and Bayesian inference. C. perfringens was found in the highest numbers for the three indicators of microbial quality, hygiene and good handling, and L. monocytogenes in the lowest. Differences in contamination levels between game species and between meats distributed as chilled or frozen products were not significant. These results might be included in quantitative exposure assessments. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Phytoextraction for clean-up of low-level uranium contaminated soil evaluated

    International Nuclear Information System (INIS)

    Vandenhove, H.; Hees, M. van

    2004-01-01

    Spills in the nuclear fuel cycle have led to soil contamination with uranium. In case of small contamination just above release levels, low-cost yet sufficiently efficient remedial measures are recommended. This study was executed to test if low-level U contaminated sandy soil from a nuclear fuel processing site could be phytoextracted in order to attain the required release limits. Two soils were tested: a control soil (317 Bq 238 U kg -1 ) and the same soil washed with bicarbonate (69 Bq 238 U kg -1 ). Ryegrass (Lolium perenne cv. Melvina) and Indian mustard (Brassica juncea cv. Vitasso) were used as test plants. The annual removal of soil activity by the biomass was less than 0.1%. The addition of citric acid (25 mmol kg -1 ) 1 week before the harvest increased U uptake up to 500-fold. With a ryegrass and mustard yield of 15,000 and 10,000 kg ha -1 , respectively, up to 3.5% and 4.6% of the soil activity could be removed annually by the biomass. With a desired activity reduction level of 1.5 and 5 for the bicarbonate-washed and control soil, respectively, it would take 10-50 years to attain the release limit. However, citric acid addition resulted in a decreased dry weight production

  15. Acceptable contamination levels in solar grade silicon: From feedstock to solar cell

    International Nuclear Information System (INIS)

    Hofstetter, J.; Lelievre, J.F.; Canizo, C.; Luque, A. del

    2009-01-01

    Ultimately, alternative ways of silicon purification for photovoltaic applications are developed and applied. There is an ongoing debate about what are the acceptable contamination levels within the purified silicon feedstock to specify the material as solar grade silicon. Applying a simple model and making some additional assumptions, we calculate the acceptable contamination levels of different characteristic impurities for each fabrication step of a typical industrial mc-Si solar cell. The acceptable impurity concentrations within the finished solar cell are calculated for SRH recombination exclusively and under low injection conditions. It is assumed that during solar cell fabrication impurity concentrations are only altered by a gettering step. During the crystallization process, impurity segregation at the solid-liquid interface and at extended defects are taken into account. Finally, the initial contamination levels allowed within the feedstock are deduced. The acceptable concentration of iron in the finished solar cell is determined to be 9.7x10 -3 ppma whereas the concentration in the silicon feedstock can be as high as 12.5 ppma. In comparison, the titanium concentration admitted in the solar cell is calculated to be 2.7x10 -4 ppma and the allowed concentration of 2.2x10 -2 ppma in the feedstock is only two orders of magnitude higher. Finally, it is shown theoretically and experimentally that slow cooling rates can lead to a decrease of the interstitial Fe concentration and thus relax the purity requirements in the feedstock.

  16. Building classification trees to explain the radioactive contamination levels of the plants

    International Nuclear Information System (INIS)

    Briand, B.

    2008-04-01

    The objective of this thesis is the development of a method allowing the identification of factors leading to various radioactive contamination levels of the plants. The methodology suggested is based on the use of a radioecological transfer model of the radionuclides through the environment (A.S.T.R.A.L. computer code) and a classification-tree method. Particularly, to avoid the instability problems of classification trees and to preserve the tree structure, a node level stabilizing technique is used. Empirical comparisons are carried out between classification trees built by this method (called R.E.N. method) and those obtained by the C.A.R.T. method. A similarity measure is defined to compare the structure of two classification trees. This measure is used to study the stabilizing performance of the R.E.N. method. The methodology suggested is applied to a simplified contamination scenario. By the results obtained, we can identify the main variables responsible of the various radioactive contamination levels of four leafy-vegetables (lettuce, cabbage, spinach and leek). Some extracted rules from these classification trees can be usable in a post-accidental context. (author)

  17. PROCEEDINGS WITH CONTAMINATED INDUSTRIAL SITES IN TERMS OF NEW LEGISLATION – PART I. HISTORICAL POLLUTION OF THE EARTH'S SURFACE

    Directory of Open Access Journals (Sweden)

    Magdalena Paulina Wiśniewska

    2017-02-01

    Full Text Available This article shows a way of dealing with the industrial areas, where historical contamination of the earth’s surface occurred, together with an indication of the proper remediation method selection. Public Administration authorities, including the Regional Director of Environmental Protection (RDOŚ and the governor are responsible, among others, for identifying areas where historical contamination or potential historical contamination of the earth's surface occurred. General Director of Environmental Protection is responsible for conducting and updating the registry, which contains information on identified by RDOŚ and district governor contaminated areas. The article discusses also issues related to the duties and responsibilities wielding the earth's surface, as well as the costs of using the environment, taking into account the "polluter pays" principle.

  18. Thallium dispersal and contamination in surface sediments from South China and its source identification.

    Science.gov (United States)

    Liu, Juan; Wang, Jin; Chen, Yongheng; Shen, Chuan-Chou; Jiang, Xiuyang; Xie, Xiaofan; Chen, Diyun; Lippold, Holger; Wang, Chunlin

    2016-06-01

    Thallium (Tl) is a non-essential element in humans and it is considered to be highly toxic. In this study, the contents, sources, and dispersal of Tl were investigated in surface sediments from a riverine system (the western Pearl River Basin, China), whose catchment has been contaminated by mining and roasting of Tl-bearing pyrite ores. The isotopic composition of Pb and total contents of Tl and other relevant metals (Pb, Zn, Cd, Co, and Ni) were measured in the pyrite ores, mining and roasting wastes, and the river sediments. Widespread contamination of Tl was observed in the sediments across the river, with the highest concentration of Tl (17.3 mg/kg) measured 4 km downstream from the pyrite industrial site. Application of a modified Institute for Reference Materials and Measurement (IRMM) sequential extraction scheme in representative sediments unveiled that 60-90% of Tl and Pb were present in the residual fraction of the sediments. The sediments contained generally lower (206)Pb/(207)Pb and higher (208)Pb/(206)Pb ratios compared with the natural Pb isotope signature (1.2008 and 2.0766 for (206)Pb/(207)Pb and (208)Pb/(206)Pb, respectively). These results suggested that a significant fraction of non-indigenous Pb could be attributed to the mining and roasting activities of pyrite ores, with low (206)Pb/(207)Pb (1.1539) and high (208)Pb/(206)Pb (2.1263). Results also showed that approximately 6-88% of Tl contamination in the sediments originated from the pyrite mining and roasting activities. This study highlights that Pb isotopic compositions could be used for quantitatively fingerprinting the sources of Tl contamination in sediments. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Use of a fractal-like gold nanostructure in surface-enhanced raman spectroscopy for detection of selected food contaminants.

    Science.gov (United States)

    He, Lili; Kim, Nam-Jung; Li, Hao; Hu, Zhiqiang; Lin, Mengshi

    2008-11-12

    The safety of imported seafood products because of the contamination of prohibited substances, including crystal violet (CV) and malachite green (MG), raised a great deal of concern in the United States. In this study, a fractal-like gold nanostructure was developed through a self-assembly process and the feasibility of using surface-enhanced Raman spectroscopy (SERS) coupled with this nanostructure for detection of CV, MG, and their mixture (1:1) was explored. SERS was capable of characterizing and differentiating CV, MG, and their mixture on fractal-like gold nanostructures quickly and accurately. The enhancement factor of the gold nanostructures could reach an impressive level of approximately 4 x 10(7), and the lowest detectable concentration for the dye molecules was at approximately 0.2 ppb level. These results indicate that SERS coupled with fractal-like gold nanostructures holds a great potential as a rapid and ultra-sensitive method for detecting trace amounts of prohibited substances in contaminated food samples.

  20. Wipe-rinse technique for quantitating microbial contamination on large surfaces

    Science.gov (United States)

    Kirschner, L. E.; Puleo, J. R.

    1979-01-01

    The evaluation of an improved wipe-rinse technique for the bioassay of large areas was undertaken due to inherent inadequacies in the cotton swab-rinse technique to which assay of spacecraft is currently restricted. Four types of contamination control cloths were initially tested. A polyester-bonded cloth (PBC) was selected for further evaluation because of its superior efficiency and handling characteristics. Results from comparative tests with PBC and cotton swabs on simulated spacecraft surfaces indicated a significantly higher recovery efficiency for the PBC than for the cotton (90.4 versus 75.2%). Of the sampling area sites studied, PBC was found to be most effective on surface areas not exceeding 0.74 sq m (8.0 sq ft).

  1. HTO transfer from contaminated surfaces to the atmosphere: a database for model validation

    International Nuclear Information System (INIS)

    Davis, P.A.; Amiro, B.D.; Workman, W.J.G.; Corbett, B.J.

    1996-12-01

    This report comprises a detailed database that can be used to validate models of the emission of tritiated water vapour (HTO) from natural contaminated surfaces to the atmosphere. The data were collected in 1992 July during an intensive field study based on the flux-gradient method of micrometeorology. The measurements were made over a wetland area at the Chalk River Laboratories, and over a grassed field near the Pickering Nuclear Generating Station. The study sites, the sampling protocols and the analytical techniques are described in detail, and the measured fluxes are presented. The report also contains a detailed listing of HTO concentrations in air at two heights, HTO concentrations in the source compartments (soil, surface water and vegetation), supporting meteorological data, and various vegetation and soil properties. The uncertainties in all of the measured data are estimated. (author). 15 refs., 23 tabs., 9 figs

  2. A survey of Cr(VI) contamination of surface water in the proximity of ...

    African Journals Online (AJOL)

    2013-07-30

    Jul 30, 2013 ... In this study, Cr(VI) levels present in surface water within the vicinity of ferrochrome smelters located in .... flict in literature pertaining to the toxicity or carcinogenicity ..... Due to the potential human health risks associated with.

  3. Nano-TiO2-based photocatalytic disinfection of environmental surfaces contaminated by meticillin-resistant Staphylococcus aureus.

    Science.gov (United States)

    Petti, S; Messano, G A

    2016-05-01

    Traditional cleaning and disinfection methods are inefficient for complete decontamination of hospital surfaces from meticillin-resistant Staphylococcus aureus (MRSA). Additional methods, such as nano-TiO2-based photocatalytic disinfection (PCD), could be helpful. To evaluate anti-MRSA activity of PCD on polyvinyl chloride (PVC) surfaces in natural-like conditions. Two identical PVC surfaces were used, and nano-TiO2 was incorporated into one of them. The surfaces were contaminated with MRSA isolated from hospitalized patients using a mist sprayer to simulate the mode of environmental contamination caused by a carrier. MRSA cell density was assessed before contamination until 180min after contamination using Rodac plates. The differences between test and control surfaces in terms of MRSA density and log MRSA density reduction were assessed using parametric and non-parametric statistical tests. Five strains were tested, and each strain was tested five times. The highest median MRSA densities [46.3 and 43.1 colony-forming units (cfu)/cm(2) for control and test surfaces, respectively] were detected 45min after contamination. Median MRSA densities 180min after contamination were 10.1 and 0.7cfu/cm(2) for control and test surfaces, respectively (Pdisinfectant activity remained stable throughout the 25 testing occasions, despite between-test cleaning and disinfection. The anti-MRSA activity of PCD was compatible with the benchmark for surface hygiene in hospitals (surfaces. However, for clinical surfaces, PCD should be regarded as supplemental to conventional decontamination procedures, rather than an alternative. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  4. [The study of the contamination and the levels of Campylobacter spp. during the processing of selected types of foods].

    Science.gov (United States)

    Efimochkina, N R; Bykova, I B; Stetsenko, V V; Minaeva, L P; Pichugina, T V; Markova, Yu M; Korotkevich, Yu V; Kozak, S S; Sheveleva, S A

    2016-01-01

    The purpose of the work was to study the nature of the Campylobacter spp. contamination during the processing of food products of plant and animal origin (raw poultry and beef meat, raw milk, leafy salads, sliced raw vegetables). In the study of 148 samples 50 strains of Campylobacter spp. (33.8%) were found. For the main phenotypic characteristics they were identified as C. jejuni spp. jejuni and C. jejuni spp. doylei (over 75%). The highest level of detection of campylobacteria (over 45%) was set for raw poultry, including the carcasses of chickens broilers, quails, turkeys and their semi-finished products. 19 of the 27 strains from poultry were identified as C. jejuni. Among the strains isolated from the environment, including swabs from equipment surfaces, 91% of the isolates were also presented by C. jejuni. It was found that the investigated foodstuffs were characterized by high levels of contamination with bacteria of the family Enterobacteriaceae, the content of which was comparable with the identified values of total viable bacteria (cfu). Salmonella was detected in 19% of the investigated poultry samples and in 14.3% of raw cow milk. In the study of swabs from surfaces of poultry processing equipment, the frequency of detection of Campylobacter strains was 38.7%, Salmonella - 12.9%. Most commonly Campylobacter and Salmonella were detected in the zones of primary processing of poultry: the frequency of isolation of Salmonella in slaughter corner was 25%, Campylobacter - 43%. When testing the swabs taken in the cooking zone of «fast food» restaurants Campylobacter and Salmonella were not detected. For studying the swabs from equipment surfaces and the environment for the presence of Campylobacter spp. a modified technique of sampling was developed. The method includes a comprehensive analysis in the test area with the use of three types of media for transportation and incubation of Campylobacter spp. (Preston broth with blood, Brucella broth, Cary

  5. Heavy metal contamination in surface sediments of Yangtze River intertidal zone: An assessment from different indexes

    International Nuclear Information System (INIS)

    Zhang Weiguo; Feng Huan; Chang Jinna; Qu Jianguo; Xie Hongxia; Yu Lizhong

    2009-01-01

    Surface sediments (0-5 cm) from 59 stations within the Yangtze River intertidal zone (YRIZ) were sampled for metal contamination analysis in April and August 2005. The concentrations ranged (in mg kg -1 dry weight): Al, 40,803-97,213; Fe, 20,538-49,627; Cd, 0.12-0.75; Cr, 36.9-173; Cu, 6.87-49.7; Mn, 413-1,112; Ni, 17.6-48.0; Pb, 18.3-44.1; and Zn, 47.6-154; respectively. Among the 59 sampling stations, enrichment factors (EF) indicate enrichment of Cd (52 stations), Cr (54 stations), Cu (5 stations), Ni (26 stations), Pb (5 stations) and Zn (5 stations). Geoaccumulation indexes (I geo ) also suggest individual metal contamination in localized areas. This study indicates that Cd, Cr and Ni enrichment in the YRIZ sediment is widespread whereas Cu, Mn, Pb and Zn enrichment is localized or nonexistent. Factor and cluster analyses indicate that Cd is associated with total organic carbon whereas Cu, Cr, Ni, Pb and Zn have a close association with Mn. - Surface sediment metal enrichment is evidenced for Cd, Cr and Ni in the Yangtze River intertidal zone.

  6. Guidance and methods for satisfying low specific activity material and surface contaminated object regulatory requirements

    International Nuclear Information System (INIS)

    Pope, R.B.; Shappert, L.B.; Michelhaugh, R.D.; Boyle, R.W.; Easton, E.P.; Coodk, J.R.

    1998-01-01

    The U.S. Department of Transportation (DOT) and the U.S. Nuclear Regulatory Commission (NRC) have prepared a comprehensive set of draft guidance for shippers and inspectors to use when applying the newly imposed regulatory requirements for low specific activity (LSA) material and surface contaminated objects (SCOs). These requirements represent significant departures in some areas from the manner in which these materials and objects were regulated by the earlier versions of the regulations. The proper interpretation and application of the regulatory criteria can require a fairly complex set of decisions be made. To assist those trying these regulatory requirements, a detailed set of logic-flow diagrams representing decisions related to multiple factors were prepared and included in the draft report for comment on Categorizing and Transporting Low Specific Activity Materials and Surface Contaminated Objects, (DOT/NRC, 1997). These logic-flow diagrams, as developed, are specific to the U.S. regulations, but were readily adaptable to the IAEA regulations. The diagrams have been modified accordingly and tied directly to specific paragraphs in IAEA Safety Series No. 6. This paper provides the logic-flow diagrams adapted in the IAEA regulations, and demonstrated how these diagrams can be used to assist consignors and inspectors in assessing compliance of shipments with the LSA material and SCO regulatory requirements. (authors)

  7. Atmospheric contamination

    International Nuclear Information System (INIS)

    Gruetter, Juerg

    1997-01-01

    It is about the levels of contamination in center America, the population's perception on the problem, effects of the atmospheric contamination, effects in the environment, causes of the atmospheric contamination, possibilities to reduce the atmospheric contamination and list of Roeco Swisscontac in atmospheric contamination

  8. Levels of chemical contaminants in nonoccupationally exposed U.S. residents

    International Nuclear Information System (INIS)

    Holleman, J.W.; Hammons, A.S.

    1978-08-01

    Data are presented on the levels of all chemical contaminants resulting from environmental pollution which have been found in human tissues including blood, urine, breast milk, and tissue samples obtained at autopsy. Most data results from specific surveys to determine health hazards. The roles of trace elements and recognition of the need to determine baseline levels of chemicals introduced into the environment are factors which have motivated surveys by individual investigators. Thus, most data on chemicals in human tissues record levels of pesticides (e.g., DDT and metabolites), levels of trace metals such as lead, cadmium, and mercury, or levels of nutritionally essential elements such as zinc, copper, manganese, and fluoride. Data available on iron and calcium are not presented as their presence in the environment is generally not considered hazardous. Data on several uncommon chemicals, such as indium and ytterbium, are included basically as items of interest and to further document their presence in healthy individuals. Baseline data were presented where available to provide perspective as to chemical levels which might be expected under conditions where exposure could be considered normal or not directly related to a pollutant source. Nearly 600 cited surveys or investigations, most of which were reported within the past decade, are listed. Ninety-four different chemical contaminants, primarily trace metals and organochlorine pesticides, are reported. It is estimated that over 75% of the data published during the past 30 years on chemical contaminants derived from environmental pollution and found in human tissue in the United States are represented in this report

  9. Hierarchic levels of a system classification of radiation-contaminated landscapes

    International Nuclear Information System (INIS)

    Dolyin, V.V.; Sushchik, Yu.Ya.; Bondarenko, G.M.; Shramenko, Yi.F.; Dudar, T.V.

    2001-01-01

    Five hierarchic levels of the systematic organization of natural landscapes are determined: substantial-phase, soil-profile, biogeocenotic, landscape, and geosystematic. Systems and subsystems of compounds of chemical elements and natural and man-caused factors that characterized properties and mechanisms of ecological self-organization of biogeocenoses are brought into accordance with each level. A scheme of hierarchic subordination of systems, subsystems, and processes is worked out. Leading links of transformation and migration of radionuclides that define the contamination of tropic chains are determined

  10. Persistent organic contaminants and steroid hormones levels in Morelet's crocodiles from the Southern Gulf of Mexico.

    Science.gov (United States)

    Gonzalez-Jauregui, Mauricio; Valdespino, Carolina; Salame-Méndez, Arturo; Aguirre-León, Gustavo; Rendón-Vonosten, Jaime

    2012-04-01

    Effects of endocrine disruptors on reproductive variables of top predators, such as alligators and crocodiles, have long been cited. Due to their long life span, these predators provide us with historic contaminant annals. In this study we tried to test whether lifestyle (free-ranging vs. farm animals) and reproductive age of Morelet's crocodiles in Campeche, Mexico, affect the bioaccumulation of organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs). Subsequently, we tested to see whether their concentration was related to steroid hormones (testosterone and estradiol-17β) levels once normal cyclic hormone variation and reproductive age had been taken into account. From the group of contaminants considered (analyzed as families), only frequency of hexachlorocyclohexanes (∑HCH) and ∑PCB permitted analyses. Whereas there was a greater concentration of ∑HCH bioaccumulated by free-ranging crocodiles, ∑PCB was found in equal quantities in free-ranging and farm animals. No difference was observed in relation to reproductive age for any of the contaminants. However, ∑PCB concentrations were related to testosterone levels among female crocodiles. This androgenic effect of ∑PCB has not been reported previously. Because testosterone promotes aggressive behavior in vertebrates, excessive aggression during the estrous season, or when female crocodiles should be caring for their young, could result in reproductive failure in Morelet's crocodiles and potential long-term decline of the population.

  11. Contamination levels observed on the Belgian territory subsequent to the Chernobyl accident

    Energy Technology Data Exchange (ETDEWEB)

    Hoof, J van [State University of Ghent, Faculty of Veterinary Medicine, Gent (Belgium); Maghuin-Rogister, G [Universite de Liege, Brussels (Belgium)

    1986-07-01

    following days for regions of higher altitude (Ardennes), the food chain grass-milk was intensively surveyed in first instance in respect of iodine-131 contamination. Extensive grass sample measurements were carried out during the first week of May, until further significant deposition ceased. Milk sampling covered the most important dairies of the country, while some individual farms and even individual cows were followed continuously over the whole period of significant milk contamination. High priority was also given to the follow-up of contamination on leafy vegetables by {gamma}-spectrometry. The radioactivity in surface waters, especially those used for drinking water preparation, and in finished drinking water was monitored at high frequency for about two weeks mostly by gross B measurements. {gamma}-spectrometry on meat samples, essentially to determine the long lived isotopes of Cesium, started after the critical period for iodine contamination during the second half of May. The build up of cesium in meat is indeed a much slower process.

  12. Contamination levels observed on the Belgian territory subsequent to the Chernobyl accident

    International Nuclear Information System (INIS)

    Hoof, J. van; Maghuin-Rogister, G.

    1986-01-01

    regions of higher altitude (Ardennes), the food chain grass-milk was intensively surveyed in first instance in respect of iodine-131 contamination. Extensive grass sample measurements were carried out during the first week of May, until further significant deposition ceased. Milk sampling covered the most important dairies of the country, while some individual farms and even individual cows were followed continuously over the whole period of significant milk contamination. High priority was also given to the follow-up of contamination on leafy vegetables by γ-spectrometry. The radioactivity in surface waters, especially those used for drinking water preparation, and in finished drinking water was monitored at high frequency for about two weeks mostly by gross B measurements. γ-spectrometry on meat samples, essentially to determine the long lived isotopes of Cesium, started after the critical period for iodine contamination during the second half of May. The build up of cesium in meat is indeed a much slower process

  13. Levels of concern for radioactive contaminations in soil according to soil protection standards

    International Nuclear Information System (INIS)

    Gellermann, R.; Barkowski, D.; Machtolf, M.

    2016-01-01

    In the paper the question is examined whether the established soil protection standards for carcinogenic substances are also applicable to the assessment of radioactive soil contamination. Referring to the methods applied in soil protection for evaluation of dose-effectrelations and estimations of carcinogenic risks as well as the calculation methods for test values in soil protection ''levels of concern'' for soil contamination by artificial radionuclides are derived. The values obtained are significantly larger than the values for unrestricted clearance of ground according to the German Radiation Protection Ordinance (StrlSchV). The thesis that soil is protected according to environmental standards provided that radiation protection requirements are met needs further checks but can be probably confirmed if the radiation protection requirements are clearly defined.

  14. Occupational exposure to beryllium in French enterprises: a survey of airborne exposure and surface levels.

    Science.gov (United States)

    Vincent, Raymond; Catani, Jacques; Créau, Yvon; Frocaut, Anne-Marie; Good, Andrée; Goutet, Pierre; Hou, Alain; Leray, Fabrice; André-Lesage, Marie-Ange; Soyez, Alain

    2009-06-01

    An assessment survey of occupational exposure to beryllium (Be) was conducted in France between late 2004 and the end of 2006. Exposure estimates were based on the analytical results of samples collected from workplace air and from work surfaces in 95 facilities belonging to 37 sectors of activity. The results of this study indicated airborne Be concentrations in excess of the occupational exposure limit value of 2 microg m(-3) recommended in France. Metallurgy and electronic component manufacturing represented the activities and occupations where workers had the highest arithmetic mean exposures to Be. Surface contamination levels were also high and frequently exceeded thresholds recommended by different bodies. These results should prompt the development of prevention programmes that include Be substitution, process control and surface decontamination, in conjunction with suitable medical surveillance.

  15. Solutal Marangoni flows of miscible liquids drive transport without surface contamination

    Science.gov (United States)

    Kim, Hyoungsoo; Muller, Koen; Shardt, Orest; Afkhami, Shahriar; Stone, Howard A.

    2017-11-01

    Mixing and spreading of different liquids are omnipresent in nature, life and technology, such as oil pollution on the sea, estuaries, food processing, cosmetic and beverage industries, lab-on-a-chip devices, and polymer processing. However, the mixing and spreading mechanisms for miscible liquids remain poorly characterized. Here, we show that a fully soluble liquid drop deposited on a liquid surface remains as a static lens without immediately spreading and mixing, and simultaneously a Marangoni-driven convective flow is generated, which are counterintuitive results when two liquids have different surface tensions. To understand the dynamics, we develop a theoretical model to predict the finite spreading time and length scales, the Marangoni-driven convection flow speed, and the finite timescale to establish the quasi-steady state for the Marangoni flow. The fundamental understanding of this solutal Marangoni flow may enable driving bulk flows and constructing an effective drug delivery and surface cleaning approach without causing surface contamination by immiscible chemical species.

  16. Surface core-level shifts for simple metals

    DEFF Research Database (Denmark)

    Aldén, Magnus; Skriver, Hans Lomholt; Johansson, Börje

    1994-01-01

    screening, whereby a SCLS becomes equivalent to the surface segregation energy of a core-ionized atom, a quantity we obtain by separate bulk and surface impurity calculations. The results are in good agreement with experiment in most of those cases where the data originates from single-crystal measurements....... We discuss the surface shifts of the electrostatic potentials and the band centers in order to trace the microscopic origin of the SCLS in the simple metals and find that the anomalous subsurface core-level shifts in beryllium are caused by charge dipoles, which persist several layers into the bulk...

  17. Microbial contaminants isolated from items and work surfaces in the post- operative ward at Kawolo general hospital, Uganda.

    Science.gov (United States)

    Sserwadda, Ivan; Lukenge, Mathew; Mwambi, Bashir; Mboowa, Gerald; Walusimbi, Apollo; Segujja, Farouk

    2018-02-06

    Nosocomial infections are a major setback in the healthcare delivery system especially in developing countries due to the limited resources. The roles played by medical care equipment and work surfaces in the transmission of such organisms have inevitably contributed to the elevated mortality, morbidity and antibiotic resistances. A total 138 samples were collected during the study from Kawolo general hospital. Swab samples were collected from various work surfaces and fomites which consisted of; beds, sink taps, infusion stands, switches, work tables and scissors. Cultures were done and the susceptibility patterns of the isolates were determined using Kirby Bauer disc diffusion method. Data was analyzed using Stata 13 and Microsoft Excel 2013 packages. A total of 44.2% (61/138) of the collected swab specimens represented the overall bacterial contamination of the sampled articles. Staphylococcus aureus and Klebsiella pneumoniae accounted for the highest bacterial contaminants constituting of 75.4% (46/61) and 11.5% (7/61) respectively. Infusion stands and patient beds were found to have the highest bacterial contamination levels both constituting 19.67% (12/61). The highest degree of transmission of organisms to patients was found to be statistically significant for patient beds with OR: 20.1 and P-value 8X10 - 4 . Vancomycin, ceftriaxone and ciprofloxacin were the most effective antibiotics with 100%, 80% and 80% sensitivity patterns among the isolates respectively. Multi-drug resistant (MDR) Staphylococcus aureus accounted for 52% (24/46) with 4% (1/24) classified as a possible extensively drug resistant (XDR) whereas Gram negative isolates had 27% (4/15) MDR strains out of which 50%(2/4) were classified as possible pan-drug resistant (PDR). The high prevalence of bacterial contaminants in the hospital work environment is an indicator of poor or ineffective decontamination. The study findings reiterate the necessity to formulate drug usage policies and re

  18. Beta Autoradiography. An analytical technique to investigate radionuclides contamination on surface

    International Nuclear Information System (INIS)

    Ficher, P.; Goutelard, F.; Siitari-Kauppi, M.

    2012-01-01

    In decommissioning of old buildings and after disposal of nuclear facilities (materials, glove boxes,...), the inventory of the radioactive contamination of various building materials needs to be obtained in order to fix the working condition for dismantling. The challenge of this study was to classify different building materials of a whole research laboratory that was dedicated to research on organic molecules labeled with H-3 and C-14. The problem of waste classification is essential for safety treatment of waste and also for its cost. The analytical technique of beta autoradiography particularly well known for biological researches has been tested to investigate radionuclides contamination on surface. This technique is mainly interesting for beta and alpha emitters but also sensitive to gamma radiation. The first step of this technique is the deposit of a film on the surface of material to be analyzed. Films can be deposited on the ground or also fixed on the walls or even on the ceiling. The film is a plastic sheet covered with an emulsion containing photostimulable crystals and Eu that is activated when the film is exposed on radioactive source. The exposed films are then scanned with the Cyclone Plus equipment to get a digitized image. This image represents the radioactivity of the surface studied. The possibility to re-use the films is very important to investigate a large area. This autoradiography technique has retained our attention for its sensitivity and moreover the possibility of 2-dimensional investigation has been found as a real advantage. However it remains now as a qualitative technique and new studies must be launched to prove its quantitative potentialities. The high spatial resolution was not as important as in biological observation, and the mm resolution is totally sufficient

  19. Final report: survey and removal of radioactive surface contamination at environmental restoration sites, Sandia National Laboratories/New Mexico. Volume 1

    International Nuclear Information System (INIS)

    Lambert, K.A.; Mitchell, M.M.; Jean, D.; Brown, C.; Byrd, C.S.

    1997-09-01

    This report describes the survey and removal of radioactive surface contamination at Sandia's Environmental Restoration (ER) sites. Radiological characterization was performed as a prerequisite to beginning the Resource Conservation and Recovery Act (RCRA) corrective action process. The removal of radioactive surface contamination was performed in order to reduce potential impacts to human health and the environment. The predominant radiological contaminant of concern was depleted uranium (DU). Between October 1993 and November 1996 scanning surface radiation surveys, using gamma scintillometers, were conducted at 65 sites covering approximately 908 acres. A total of 9,518 radiation anomalies were detected at 38 sites. Cleanup activities were conducted between October 1994 and November 1996. A total of 9,122 anomalies were removed and 2,072 waste drums were generated. The majority of anomalies not removed were associated with a site that has subsurface contamination beyond the scope of this project. Verification soil samples (1,008 total samples) were collected from anomalies during cleanup activities and confirm that the soil concentration achieved in the field were far below the target cleanup level of 230 pCi/g of U-238 (the primary constituent of DU) in the soil. Cleanup was completed at 21 sites and no further radiological action is required. Seventeen sites were not completed since cleanup activities wee precluded by ongoing site activity or were beyond the original project scope

  20. Final report: survey and removal of radioactive surface contamination at environmental restoration sites, Sandia National Laboratories/New Mexico. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Lambert, K.A.; Mitchell, M.M. [Brown and Root Environmental, Albuquerque, NM (United States); Jean, D. [MDM/Lamb, Inc., Albuquerque, NM (United States); Brown, C. [Environmental Dimensions, Inc., Albuquerque, NM 87109 (United States); Byrd, C.S. [Sandia National Labs., Albuquerque, NM (United States)

    1997-09-01

    This report describes the survey and removal of radioactive surface contamination at Sandia`s Environmental Restoration (ER) sites. Radiological characterization was performed as a prerequisite to beginning the Resource Conservation and Recovery Act (RCRA) corrective action process. The removal of radioactive surface contamination was performed in order to reduce potential impacts to human health and the environment. The predominant radiological contaminant of concern was depleted uranium (DU). Between October 1993 and November 1996 scanning surface radiation surveys, using gamma scintillometers, were conducted at 65 sites covering approximately 908 acres. A total of 9,518 radiation anomalies were detected at 38 sites. Cleanup activities were conducted between October 1994 and November 1996. A total of 9,122 anomalies were removed and 2,072 waste drums were generated. The majority of anomalies not removed were associated with a site that has subsurface contamination beyond the scope of this project. Verification soil samples (1,008 total samples) were collected from anomalies during cleanup activities and confirm that the soil concentration achieved in the field were far below the target cleanup level of 230 pCi/g of U-238 (the primary constituent of DU) in the soil. Cleanup was completed at 21 sites and no further radiological action is required. Seventeen sites were not completed since cleanup activities wee precluded by ongoing site activity or were beyond the original project scope.

  1. Surface radiological investigations at environmental research area 11, 137Cs- and 60Co-contaminated plots at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    Uziel, M.S.; Tiner, P.F.; Williams, J.K.

    1993-02-01

    A surface radiological investigation at the 137 Cs- and 6O Co-contaminated forest area (Chestnut Ridge east and west plots) was conducted from January 1992 through August 1992. Results of the survey revealed numerous spots and small areas of surface contamination that followed the original placement of feeders used for 6O Co- and 137 Cs-labeled seeds in a 1969--1970 study. Surface gamma exposure rates reached 380 μR/h at the east plot and 400 μR/h at the west plot, but approximately one-half and one- third, respectively, of the identified anomalies did not exceed 39 μR/h. Results of soil sample analyses demonstrated that 137 Cs and 6O Co were responsible for the elevated radiation levels. Radionuclides were found below the surface at soil sample locations, in some cases at depths below 18 in. The same pattern of subsurface contamination may be present at other elevated surface spots at both plots. These survey results show that current radiological conditions at the site remain an environmental problem. Recommendations for corrective actions are included

  2. Emerging organic contaminants in surface water and groundwater: a first overview of the situation in Italy.

    Science.gov (United States)

    Meffe, Raffaella; de Bustamante, Irene

    2014-05-15

    This paper provides the first review of the occurrence of 161 emerging organic compounds (EOCs) in Italian surface water and groundwater. The reported EOCs belong to the groups of industrials, pharmaceuticals, estrogens and illicit drugs. Occurrence of 137 pesticides was also reported. The reviewed research works have been published between 1997 and 2013. The majority of the studies have been carried out in Northern Italy (n. 30) and to a lower extent in Central Italy (n. 13). Only a limited number of research studies report EOC concentrations in water resources of Southern Italy. The EOCs that have been more frequently studied are in the following descending order, pesticides (16), pharmaceuticals (15), industrials (13), estrogens (7) and illicit drugs (2). Research activities investigating the EOC occurrence in surface water are more numerous than those in groundwater. This is consistent with the higher complexity involved in groundwater sampling and EOC detection. Among the reported EOCs, industrials and pesticides are those occurring in both surface water and groundwater with the highest concentrations (up to 15 × 10(6) and 4.78 × 0(5)ng L(-1), respectively). Concentrations of pharmaceuticals in surface water reach a maximum of 3.59 × 10(3)ng L(-1), whereas only the antimicrobial agent josamycin has been encountered in groundwater with a concentration higher than 100 ng L(-1). Both estrogens and illicit drugs appeared in surface water with concentrations lower than 50 ng L(-1). Groundwater concentrations for estrogens were measured to be below the detection limits, whereas illicit drugs have so far not been studied in groundwater. The present review reveals the serious contamination status of Italian surface water and groundwater especially by pesticides, industrials and to a lower extent by pharmaceuticals and the necessity to foster the research on EOC occurrence in Italian water resources, in particular in Southern Italy where a limited number of

  3. The radioactive contamination level in Croatia by means of radioactive rainwaters, caused by the accident in NPP 'Lenin'

    International Nuclear Information System (INIS)

    Barishicj, D.; Koshuticj, K.; Kvastek, K.; Lulicj, S.; Tuta, J.; Vertachnik, A.; Vrhovac, A.

    1987-01-01

    In this paper, the radioactive contamination level in Croatia by means of radioactive rainwaters, caused by the accident in NPP 'Lenin', has been described. The results represent the sum of measured and evaluated data, the map of the radioactive contamination in Croatia caused by radioactive rainwaters between April, 28 to May, 20 1986 has been constructed. (author) 3 tabs.; 5 figs

  4. Fifth international conference on radioactive waste management and environmental remediation -- ICEM '95: Proceedings. Volume 2: Management of low-level waste and remediation of contaminated sites and facilities

    International Nuclear Information System (INIS)

    Slate, S.; Baker, R.; Benda, G.

    1995-01-01

    The objective of this conference is the broad international exchange of information on technologies, operations, management approaches, economics, and public policies in the critical areas of radioactive waste management and environmental remediation. The ICEM '95 technical program includes four parallel program tracks: Low/intermediate-level waste management; High-level waste, spent fuel, nuclear material management; Environmental remediation and facility D and D; and Major institutional issues in environmental management. Volume 2 contains approximately 200 papers divided into the following topical sections: Characterization of low and intermediate level waste; Treatment of low and intermediate level waste; LLW disposal and near-surface contaminant migration; Characterization and remediation of contaminated sites; and Decontamination and decommissioning technologies and experience. Papers have been processed separately for inclusion on the data base

  5. Dechlorination of Hexachlorobenzene in Contaminated Soils Using a Nanometallic Al/CaO Dispersion Mixture: Optimization through Response Surface Methodology

    Science.gov (United States)

    Jiang, Yuhui; Shang, Yixuan; Yu, Shuyao; Liu, Jianguo

    2018-01-01

    Hexachlorobenzene (HCB) contamination of soils remains a significant environmental challenge all over the world. Reductive stabilization is a developing technology that can decompose the HCB with a dechlorination process. A nanometallic Al/CaO (n-Al/CaO) dispersion mixture was developed utilizing ball-milling technology in this study. The dechlorination efficiency of HCB in contaminated soils by the n-Al/CaO grinding treatment was evaluated. Response surface methodology (RSM) was employed to investigate the effects of three variables (soil moisture content, n-Al/CaO dosage and grinding time) and the interactions between these variables under the Box-Behnken Design (BBD). A high regression coefficient value (R2 = 0.9807) and low p value (soil moisture content, n-Al/CaO dosage, and grinding time were found to be 7% (m/m), 17.7% (m/m), and 24 h, respectively, in the experimental ranges and levels. Under optimal conditions, the dechlorination efficiency was 80%. The intermediate product analysis indicated that dechlorination was the process by stepwise loss of chloride atoms. The main pathway observed within 24 h was HCB → pentachlorobenzene (PeCB) → 1,2,3,4-tetrachlorobenzene (TeCB) and 1,2,4,5-TeCB. The results indicated that the moderate soil moisture content was crucial for the hydrodechlorination of HCB. A probable mechanism was proposed wherein water acted like a hydrogen donor and promoted the hydrodechlorination process. The potential application of n-Al/CaO is an environmentally-friendly and cost-effective option for decontamination of HCB-contaminated soils. PMID:29702570

  6. Dechlorination of Hexachlorobenzene in Contaminated Soils Using a Nanometallic Al/CaO Dispersion Mixture: Optimization through Response Surface Methodology

    Directory of Open Access Journals (Sweden)

    Yuhui Jiang

    2018-04-01

    Full Text Available Hexachlorobenzene (HCB contamination of soils remains a significant environmental challenge all over the world. Reductive stabilization is a developing technology that can decompose the HCB with a dechlorination process. A nanometallic Al/CaO (n-Al/CaO dispersion mixture was developed utilizing ball-milling technology in this study. The dechlorination efficiency of HCB in contaminated soils by the n-Al/CaO grinding treatment was evaluated. Response surface methodology (RSM was employed to investigate the effects of three variables (soil moisture content, n-Al/CaO dosage and grinding time and the interactions between these variables under the Box-Behnken Design (BBD. A high regression coefficient value (R2 = 0.9807 and low p value (<0.0001 of the quadratic model indicated that the model was accurate in predicting the experimental results. The optimal soil moisture content, n-Al/CaO dosage, and grinding time were found to be 7% (m/m, 17.7% (m/m, and 24 h, respectively, in the experimental ranges and levels. Under optimal conditions, the dechlorination efficiency was 80%. The intermediate product analysis indicated that dechlorination was the process by stepwise loss of chloride atoms. The main pathway observed within 24 h was HCB → pentachlorobenzene (PeCB → 1,2,3,4-tetrachlorobenzene (TeCB and 1,2,4,5-TeCB. The results indicated that the moderate soil moisture content was crucial for the hydrodechlorination of HCB. A probable mechanism was proposed wherein water acted like a hydrogen donor and promoted the hydrodechlorination process. The potential application of n-Al/CaO is an environmentally-friendly and cost-effective option for decontamination of HCB-contaminated soils.

  7. A method for determining allowable residual contamination levels of radionuclide mixtures in soil

    International Nuclear Information System (INIS)

    Napier, B.A.

    1982-05-01

    An important consideration in the disposal of radioactive wastes, and consequently in the preparation of plans for remedial actions at contaminated sites, is the amount of radioactive contamination that may be allowed to remain at any particular waste site. The allowable residual contamination level (ARCL) is dependent on the radiation dose limit imposed, the physical and environmental characteristics of the waste site, and the time at which exposure to the wastes is assumed to occur. The steps in generating an ARCL are generally as follows: (1) develop plausible, credible site-specific exposure scenario; (2) calculate maximum annual radiation doses to an individual for each radionuclide based on the existing physical characteristics of the waste site and the site-specific exposure scenario; (3) calculate the ARCL for the dose limit desired, including all radionuclides present, uncorrected for site cleanup or barrier considerations; and (4) apply any corrections for proposed cleanup activity or addition of barriers to waste migration or uptake to obtain the ARCL applicable to the proposed action. Use of this method allows appropriate application of resources to achieve uniform compliance with a single regulatory standard, i.e., a radiation dose rate limit. Application and modification of the ARCL method requires appropriate models of the environmental transport and fate of radionuclides. Example calculations are given for several specific waste forms and waste site types in order to demonstrate the technique and generate comparisons with other approaches

  8. DDT in zebra mussels from Lake Maggiore (N. Italy): level of contamination and endocrine disruptions.

    Science.gov (United States)

    Binelli, Andrea; Bacchetta, Renato; Mantecca, Paride; Ricciardi, Francesco; Provini, Alfredo; Vailati, Giovanni

    2004-08-10

    The DDT contamination of Lake Maggiore (Northern Italy) has been monitored since a serious pollution event occurred in 1996. To assess the environmental risk associated with this contamination, bioaccumulation data coupled with histopathological markers were evaluated on zebra mussel populations from two different contaminated sites from April 2001 to April 2002. Biomonitoring results showed high DDT pollution in 2001 because of a flood which transported DDTs still contained in the sediments of a polluted river to the lake. DDT concentrations reached values of 4-5 microg/g lipids, higher than those recorded in other industrialized countries but comparable to levels measured in developing ones. In the ovaries of the most highly polluted mussels, histological analyses showed a delay in oocyte maturation and a high incidence of pathological pictures mainly referable to oocyte degeneration and haemocytic infiltration. Moreover, despite the presence of mature sperms, in 2001 first male gamete release occurred about 2 months later than in females. These results indicated a neuroendocrine interference of DDT on Dreissena polymorpha reproduction and also showed that these invertebrates can be successfully used to evaluate ecological implications due to exposure to endocrine disruptors in freshwater environments.

  9. A study on EUV reticle surface molecular contamination under different storage conditions in a HVM foundry fab

    Science.gov (United States)

    Singh, SherJang; Yatzor, Brett; Taylor, Ron; Wood, Obert; Mangat, Pawitter

    2017-03-01

    The prospect of EUVL (Extreme Ultraviolet Lithography) insertion into HVM (High Volume Manufacturing) has never been this promising. As technology is prepared for "lab to fab" transition, it becomes important to comprehend challenges associated with integrating EUVL infrastructure within existing high volume chip fabrication processes in a foundry fab. The existing 193nm optical lithography process flow for reticle handling and storage in a fab atmosphere is well established and in-fab reticle contamination concerns are mitigated with the reticle pellicle. However EUVL reticle pellicle is still under development and if available, may only provide protection against particles but not molecular contamination. HVM fab atmosphere is known to be contaminated with trace amounts of AMC's (Atmospheric Molecular Contamination). If such contaminants are organic in nature and get absorbed on the reticle surface, EUV photon cause photo-dissociation resulting into carbon generation which is known to reduce multilayer reflectivity and also degrades exposure uniformity. Chemical diffusion and aggregation of other ions is also reported under the e-beam exposure of a EUV reticle which is known to cause haze issues in optical lithography. Therefore it becomes paramount to mitigate absorbed molecular contaminant concerns on EUVL reticle surface. In this paper, we have studied types of molecular contaminants that are absorbed on an EUVL reticle surface under HVM fab storage and handling conditions. Effect of storage conditions (gas purged vs atmospheric) in different storage pods (Dual pods, Reticle Clamshells) is evaluated. Absorption analysis is done both on ruthenium capping layer as well as TaBN absorber. Ru surface chemistry change as a result of storage is also studied. The efficacy of different reticle cleaning processes to remove absorbed contaminant is evaluated as well.

  10. Comparative characteristics of contamination levels of food stuffs of the same type in the USSR and abroad

    International Nuclear Information System (INIS)

    Knizhnikov, V.A.; Petukhova, Eh.V.

    1980-01-01

    Studied is the contamination of similar food stuffs obtained in different distant regions which have similar geographical latitude, amounts of atmospheric fallouts, altitude above the sea level. The contamination of initial raw food stuffs deoends on other conditions, among them the main one for vegetable raw materials being sorption properties of a given plant. The mechanism is more difficult in the case of a soil way of food stuffs contamination. Food stuffs can have various degrees of contamination due to differences in the technology of processing the initial food stuffs in different countries. The data showing the differences in the contamination of similar food stuffs are presented. Differences in most cases are constant. The data presented allow to make a conclusion that food stuffs contamination in the USSR takes place in the framework of variations observed in separate countries of northern hemisphere

  11. Interconnection between precipitation density, soil contamination levels and 90Sr and 137Cs content in food stuffs

    International Nuclear Information System (INIS)

    Knizhnikov, V.A.; Petukhova, Eh.V.

    1980-01-01

    Presented are the data dynamically characterizing the density of radioactive fallout, contamination of soil and the main kinds of food stuffs with 137 Cs and 90 Sr. It is shown that 90 Sr contamination of bakery products in the country within the whole period of observation is in direct dependence on the density of atmospheric fallouts as a whole in the northern hemisphere. In the reverse, 90 Sr potato contamination primarily correlates with nuclide content in the soil. The dependence between milk contamination and fallout density has an intermediate character as compared with the above types of food stuffs. The same is true for 137 Cs, but a clear tendency to a faster decrease in the level of food stuffs contamination is observed. The importance of the soil way in food stuffs contamination and peculiarities of nuclide migration in food stuffs from various types of soil are considered

  12. Incidence and Levels of Deoxynivalenol, Fumonisins and Zearalenone Contaminants in Animal Feeds Used in Korea in 2012

    Directory of Open Access Journals (Sweden)

    Dong-Ho Kim

    2013-12-01

    Full Text Available The objective of this study was to evaluate the occurrence and levels of deoxynivalenol (DON, fumonisins B1 and B2 (FBs, and zearalenone (ZEN contaminants in animal feeds used in Korea in 2012. Contamination with DON was observed in 91.33% and 53.33% in compound feeds and feed ingredients, respectively. Among compound feeds, poultry layer feed (laying exhibited the highest contaminant level of 1.492 mg/kg. FBs contaminants were present in compound feeds and feed ingredients at 93.33% and 83.33%, respectively. Most poultry broiler (early feeds were highly contaminated with FBs, and one of these feeds detected the level as 12.823 mg/kg as the highest level. The levels of ZEN in compound feeds and feed ingredients were 71.33% and 47%, respectively. Ninety-eight percent of compound feeds for cattle were contaminated with ZEN, and the highest contamination level of 0.405 mg/kg was observed in cattle fatting feeds.

  13. The groundwater contribution to surface water contamination in a region with intensive agricultural land use (Noord-Brabant, The Netherlands)

    International Nuclear Information System (INIS)

    Rozemeijer, J.C.; Broers, H.P.

    2007-01-01

    Traditionally, monitoring of soil, groundwater and surface water quality is coordinated by different authorities in the Netherlands. Nowadays, the European Water Framework Directive (EU, 2000) stimulates an integrated approach of the complete soil-groundwater-surface water system. Based on water quality data from several test catchments, we propose a conceptual model stating that stream water quality at different discharges is the result of different mixing ratios of groundwater from different depths. This concept is used for a regional study of the groundwater contribution to surface water contamination in the Dutch province of Noord-Brabant, using the large amount of available data from the regional monitoring networks. The results show that groundwater is a dominant source of surface water contamination. The poor chemical condition of upper and shallow groundwater leads to exceedance of the quality standards in receiving surface waters, especially during quick flow periods. - Water quality monitoring data show the importance of the groundwater contribution to surface water pollution

  14. Decontamination effects of a simulated contaminated floor surface by a teleoperated mopping system

    International Nuclear Information System (INIS)

    Kim, Ki Ho; Kwon, Hyok Jo; Park, Jang Jin; Yang, Myung Seung

    2004-01-01

    A Tele Operated Mopping System (TOMS) was developed for use in the radioactive zone of the M6 hot-cell of the Irradiated Material Examination Facility (IMEF) at the Korea Atomic Energy Research Institute (KAERI). TOMS was designed to remove contaminated dry particulates, dust, and smears existing on the floor surface of the M6 hot-cell by mopping it in a remote manner. TOMS has three subsystems - a mobile mopping slave located inside the hot-cell, and a mopping master and a control console located outside the hot-cell. The mobile mopping slave consists of a tracked mobile platform, a mopping tool, and a wet mopping cloth, which were constructed in modules to facilitate a maintenance. This paper aims at describing the mopping capability of the developed TOMS - decontamination capability. In this work the decontamination capability is defined by the ratio of the removed contaminated area when the mopping cloth was passed over. The experiment was carried out by varying the speeds of the mopping slave and the roller, while the mopping force driven by the operator was constant. The roller of the mopping tool mounted on the mopping slave was designed to collect the mopping cloth used. The experimental results showed that the speeds of the mopping slave and the roller influence the extent of the decontamination

  15. Estimation of the amount of surface contamination of a water cooled nuclear reactor by cooling water analysis

    Energy Technology Data Exchange (ETDEWEB)

    Nagy, G. [KFKI Atomic Energy Research Institute, P.O. Box 49, Budapest H-1525 (Hungary)]. E-mail: nagyg@sunserv.kfki.hu; Somogyi, A. [KFKI Atomic Energy Research Institute, P.O. Box 49, Budapest H-1525 (Hungary); Patek, G. [Paks Nuclear Power Plant, P.O. Box 71, Paks H-7031 (Hungary); Pinter, T. [Paks Nuclear Power Plant, P.O. Box 71, Paks H-7031 (Hungary); Schiller, R. [KFKI Atomic Energy Research Institute, P.O. Box 49, Budapest H-1525 (Hungary)

    2007-06-15

    Calculations, based upon on-the-spot measurements, were performed to estimate the contamination of NPP primary circuit and spent fuel storage pool solid surfaces via the composition of the cooling water in connection with a non-nuclear incident in the Paks NPP. Thirty partially burnt-up fuel element bundles were damaged during a cleaning process, an incident which resulted in the presence of fission products in the cooling water of the cleaning tank (CT) situated in a separate pool (P1). Since this medium was in contact for an extended period of time with undamaged fuel elements to be used later and also with other structural materials of the spent fuel storage pool (SP), it was imperative to assess the surface contamination of these latter ones with a particular view to the amount of fission material. In want of direct methods, one was restricted to indirect information which rested mainly on the chemical and radiochemical data of the cooling water. It was found that (i) the most important contaminants were uranium, plutonium, cesium and cerium; (ii) after the isolation of P1 and SP and an extended period of filtering the only important contaminants were uranium and plutonium; (iii) the surface contamination of the primary circuit (PC) was much lower than that of either SP or P1; (iv) some 99% of the contamination was removed from the water by the end of the filtering process.

  16. Cytogenetic damage related to low levels of methyl mercury contamination in the Brazilian Amazon

    Directory of Open Access Journals (Sweden)

    MARÚCIA I. M. AMORIM

    2000-12-01

    Full Text Available The mercury rejected in the water system, from mining operations and lixiviation of soils after deforestation, is considered to be the main contributors to the contamination of the ecosystem in the Amazon Basin. The objectives of the present study were to examine cytogenetic functions in peripheral lymphocytes within a population living on the banks of the Tapajós River with respect to methylmercury (MeHg contamination, using hair mercury as a biological indicator of exposure. Our investigation shows a clear relation between methylmercury contamination and cytogenetic damage in lymphocytes at levels well below 50 micrograms/gram, the level at which initial clinical signs and symptoms of mercury poisoning occur. The first apparent biological effect with increasing MeHg hair level was the impairment of lymphocyte proliferation measured as mitotic index (MI. The relation between mercury concentration in hair and MI suggests that this parameter, an indicator of changes in lymphocytes and their ability to respond to culture conditions, may be an early marker of cytotoxicity and genotoxicity in humans and should be taken into account in the preliminary evaluation of the risks to populations exposed in vivo. This is the first report showing clear cytotoxic effects of long-term exposure to MeHg. Although the results strongly suggest that, under the conditions examined here, MeHg is both a spindle poison and a clastogen, the biological significance of these observations are as yet unknown. A long-term follow-up of these subjects should be undertaken.

  17. Laser-induced damage of fused silica at 355 and 1065 nm initiated at aluminum contamination particles on the surface

    International Nuclear Information System (INIS)

    Genin, F.Y.; Michlitsch, K.; Furr, J.; Kozlowski, M.R.; Krulevitch, P.

    1997-01-01

    1-μm thick circular dots, 10-250 μm dia, were deposited onto 1.14 cm thick fused silica windows by sputtering Al through a mask. Al shavings were also deposited on the windows to investigate effects of particle-substrate adhesion. The silica windows were then illuminated repetitively using a 3-ns, 355 nm and an 8.6-ns, 1064 nm laser. The tests were conducted at near normal incidence with particles on input and output surfaces of the windows. During the first shot, a plasma ignited at the metal particle and damage initiated on the fused silica surface. The morphology of the damage at the metal dots were reproducible but different for input and output surface contamination. For input surface contamination, minor damage occurred where the particle was located; such damage ceased to grow with the removal of contaminant material. More serious damage (pits and cracks) was initiated on the output surface (especially at 355 nm) and grew to catastrophic proportions after few shots. Output surface contaminants were usually ejected on the initial shot, leaving a wave pattern on the surface. No further damage occurred with subsequent shots unless a shot (usually the first shot) cracked the surface; such behavior was mostly observed at 355 nm and occasionally for large shavings at 1064 nm. The size of the damaged area scaled with the size of the particle (except when catastrophic damage occurred). Onset of catastrophic damage on output surface occurred only when particles exceeded a critical size. Damage behavior of the sputtered dots was found to be qualitatively similar to that of the shavings. The artificial contamination technique accelerated the study by allowing better control of the test conditions

  18. Agricultural contamination in soil-groundwater-surface water systems in the North China Plain

    DEFF Research Database (Denmark)

    Brauns, Bentje

    of fertilizers and pesticides. Unfortunately, the lack of regulation or oversight has led to the overuse of these agrochemicals: current application rates (in kg/ha) are two- to threefold higher than in most developed countries, and this is taking its toll on the environment. Problems include severe surface...... water and groundwater pollution by nitrogen and pesticides, soil degradation, bioaccumulation of toxic compounds, and more. It is crucial for China to do improve the safeguarding of its water resources in order to sustain the livelihoods of its people and ensure safe supply of drinking water. Recently......-groundwater interaction was chosen, and field work was performed between October 2012 and March 2014. Results from the field study showed that fertilizer inputs were excessive, and could be reduced substantially. Contaminated river water was infiltrating – and carrying ammonium pollution – into the shallow groundwater...

  19. The Mobile Surface Contamination Monitor II environmental radiological characterization utilizing GPS/GIS technologies

    International Nuclear Information System (INIS)

    Wendling, M.A.

    1993-05-01

    Time, cost, and most importantly quality of data are the three factors to measure the success of field radiological characterizations. The application of coupling radiation detection instrumentation to a GPS receiver has dramatically increased the data quality achievable compared to traditional environmental radiological survey methods. Improvements in verifying adequate spatial coverage of an area while collecting data and at,the same time reducing field time requirements can be realized. Data acquired during the recent implementation of the Mobile Surface Contamination Monitor 11 (MSCM-11) will be presented to demonstrate the advantages of this system over traditional radiological survey methods. The comparison will include time and manpower requirements. Linking the complimentary GPS, GIS and radiation detection technologies on a mobile tractor based platform has provided a tool to provide radiological characterization data faster, cheaper, and better to assist in the Environmental Restoration Mission of the Hanford Site

  20. Radioecological state of some surface water systems of contaminated areas of both Gomel and Mogilev Regions

    International Nuclear Information System (INIS)

    Datskevich, P. I.; Komissariv, F. D.; Khvale', O. D.; Basharina, L. P.; Lobach, I. L.

    1997-01-01

    The radioecological situation of different ecosystems of Belarus and their components has been analysed. Such components of the surface water ecosystems as water, suspensions, sediments and soils of water-collection areas were used for the investigation of the content of cesium 137 and strontium 90. The received data were given since 1990. The content of cesium 137 and strontium 90 in the components of water ecosystems was counted in the laboratory conditions by means of standard methods of beta radiometry, semiconductor gamma spectrometry and radiochemistry. The error of measurement of radioactivity was not higher than 25 and 35% for cesium 137 and strontium 90 accordingly. Water ecosystems were distinguished by the state of contamination of water-collection areas and hydrological parameters. These and some other reasons considered in the article influence on the character of cesium 137 and strontium 90 behaviour in water ecosystems

  1. Absorption and backscatter of internal conversion electrons in the measurements of surface contamination of 137Cs

    International Nuclear Information System (INIS)

    Yunoki, A.; Kawada, Y.; Yamada, T.; Unno, Y.; Sato, Y.; Hino, Y.

    2013-01-01

    We measured 4π and 2π counting efficiencies for internal conversion electrons (ICEs), gross β-particles and also β-rays alone with various source conditions regarding absorber and backing foil thickness using e-X coincidence technique. Dominant differences regarding the penetration, attenuation and backscattering properties among ICEs and β-rays were revealed. Although the abundance of internal conversion electrons of 137 Cs- 137 Ba is only 9.35%, 60% of gross counts may be attributed to ICEs in worse source conditions. This information will be useful for radionuclide metrology and for surface contamination monitoring. - Highlights: • Counting efficiencies for internal conversion electrons from 137 Cs were measured, and compared with those for β-rays. • Electron-X coincidence technique was employed. • A thin NaI(Tl) scintillation detector was used for X-ray detection. • Backscattering fractions of electrons and beta particles were studied by similar experiments

  2. Risk assessing heavy metals in the groundwater-surface water interface at a contaminated site

    DEFF Research Database (Denmark)

    Bigi, Giovanni; McKnight, Ursula S.; Bjerg, Poul Løgstrup

    such as surface water and groundwater (EC, 2017). The current study quantified and assessed the contamination of As, Cd, Cr, Cu, Ni, Pb and Zn in the shallow aquifer, hyporheic zone, stream water and streambed sediments at Rådvad site, a former metal manufacturing industrial area located in Denmark, investigating...... in the soil). Stream water was sampled in 12 points, while groundwater was sampled in 4 wells close to the stream where the interaction was suspected. Sediments and hyporheic zone were sampled in pair, where upward hydraulic heads have been detected. A drain discharging in the river was also sampled....... Sediments were divided in different layers and both heavy metal total concentration and chemical partitioning were analysed. Redox species and dissolved organic matter were also analysed in the water samples, while fraction of organic carbon was investigated in the extracted sediments. Results showed a high...

  3. Removal of Airborne Contaminants from a Surface Tank by a Push-Pull System

    DEFF Research Database (Denmark)

    Heiselberg, Per; Topp, Claus

    Open surface tanks are used in many industrial processes, and local exhaust systems are often designed to capture and remove toxic fumes diffused from materials in the tanks prior to their escape into the workplace environment. The push-pull system seems to be the most efficient local exhaust...... system, but proper design is required to ensure health and safety of the workers and, furthermore, it is very desirable from an energy conservation point of view to determine an optimum and -an efficient design of push-pull hoods which can exhaust all contaminants with a minimum quantity of volume flow....... The paper describes and discusses different design methods and compares designed values with results from a measurement series of push-pull system efficiency....

  4. Application of gelatin zymography for evaluating low levels of contaminating neutrophils in red blood cell samples.

    Science.gov (United States)

    Achilli, Cesare; Ciana, Annarita; Balduini, Cesare; Risso, Angela; Minetti, Giampaolo

    2011-02-15

    Supposedly "homogeneous" red blood cell (RBC) samples are commonly obtained by "washing" whole blood free of plasma, platelets, and white cells with physiological solutions, a procedure that does not result, however, in sufficient removal of polymorphonuclear neutrophils (PMNs), leading to possible artifactual results. Pure RBC samples can be obtained only by leukodepletion procedures. Proposed here is a version of gelatin zymography adapted to detect matrix metalloproteinase 9 (MMP-9), selectively expressed by PMNs, in heterogeneous mixtures of RBCs and PMNs that can reveal contamination at levels as low as 1 PMN/10⁶ RBCs. Copyright © 2010 Elsevier Inc. All rights reserved.

  5. Allowable residual contamination levels: transuranic advanced disposal systems for defense waste

    International Nuclear Information System (INIS)

    Kennedy, W.E. Jr.; Napier, B.A.

    1982-01-01

    An evaluation of advanced disposal systems for defense transuranic (TRU) wastes is being conducted using the Allowable Residual Contamination Level (ARCL) method. The ARCL method is based on compliance with a radiation dose rate limit through a site-specific analysis of the potential for radiation exposure to individuals. For defense TRU wastes at the Hanford Site near Richland, Washington, various advanced disposal techniques are being studied to determine their potential for application. This paper presents a discussion of the results of the first stage of the TRU advanced disposal systems project

  6. Absorption of technetium by plants in relation to soil type contamination level and time

    Energy Technology Data Exchange (ETDEWEB)

    Mousny, J.M.; Myttenaere, C. (Louvain Univ. (Belgium). Lab. de Physiologie Vegetale)

    1981-01-01

    Plants of Pisum sativum (var. Merveille de Kelvedon) were grown on seven typical european soils contaminated with different levels of /sup 99/Tc(0.17; 1.7 and 17 ..mu..Ci/kg). Added initially as pertechnetate, the technetium absorption has been studied for three successive cultures. The translocation of technetium from soil to plant leaves is high, but its transfer is reduced in soils rich in organic matter (Fen) or poorly drained (Braunerde). Aging reduces the technetium transfer and modify its relative distribution in plant (relatively more technetium is found in fruits); these results let suppose some modification of the technetium chemical form in soils with time.

  7. Levels and distribution of organohalogenated contaminants in 5 fish species from Sir Dam Lake, Kahramanmaras, Turkey

    Energy Technology Data Exchange (ETDEWEB)

    Erdogrul, Oe [Faculty of Agriculture, Kahramanmaras (Turkey). Dept. of Food Engineering; Covaci, A; Schepens, P [Antwerp Univ. (Belgium). Toxicological Center

    2004-09-15

    In Turkey, OCPs have been used since 1945, with large quantities of these chemicals being used during the 1960s and 1970s. Since 1983, the usage of OCPs has been severely restricted or banned. Only few studies have investigated the presence of OCPs in Turkish aquatic environment, where they have been evidenced in relatively high concentrations. The aim of this study was to investigate the levels and distribution of organohalogenated contaminants in several fish species from Syr Dam Lake (Kahramanmarab, Turkey), an artificial lake with great economical importance for the region.

  8. Immobilized enzymes: understanding enzyme - surface interactions at the molecular level.

    Science.gov (United States)

    Hoarau, Marie; Badieyan, Somayesadat; Marsh, E Neil G

    2017-11-22

    Enzymes immobilized on solid supports have important and industrial and medical applications. However, their uses are limited by the significant reductions in activity and stability that often accompany the immobilization process. Here we review recent advances in our understanding of the molecular level interactions between proteins and supporting surfaces that contribute to changes in stability and activity. This understanding has been facilitated by the application of various surface-sensitive spectroscopic techniques that allow the structure and orientation of enzymes at the solid/liquid interface to be probed, often with monolayer sensitivity. An appreciation of the molecular interactions between enzyme and surface support has allowed the surface chemistry and method of enzyme attachement to be fine-tuned such that activity and stability can be greatly enhanced. These advances suggest that a much wider variety of enzymes may eventually be amenable to immobilization as green catalysts.

  9. Levels of contamination for various pollutants present in Belgian human plasma

    Energy Technology Data Exchange (ETDEWEB)

    Wouwe, N. Van; Goeyens, L. [Scientific Inst. of Public Health, Brussels (Belgium); Covaci, A. [Toxicological Center, Univ. of Antwerp, Wilrijk (Belgium); Kannan, K. [Wadsworth Center, New York State Dept. of Health, Albany, NY (United States); Gordon, J.; Chu, A. [Xenobiotic Detection System Inc., Durham, NC (United States); Eppe, G.; Pauw, E. De [Center of Analysis of residues in Traces (CART), Univ. of Liege (Belgium)

    2004-09-15

    During the last century, numerous compounds, such as polychlorinated biphenyls (PCBs) or organochlorine pesticides (OCPs), were banned because of their bioaccumulative and toxic properties, while other compounds, such as polybrominated diphenyl ethers (PBDEs), appeared on the market and consequently in the environment. The experiences gained from accidents involving PBBs, PCBs or PCDD/Fs are useful to conduct scientific investigations focused on preventing similar catastrophies with the newly introduced compounds. Several studies have reported potential increase in the concentration of PBDEs in food and wildlife. Monitoring the levels of toxic chemicals is therefore useful to understand the exposure pathways, sources and trends. The aim of the paper is to present actual contamination's levels of various pollutants in human plasma from Belgium. Several classes of pollutants, such PCDD/Fs, PCBs and OCPs were determined in 20 human plasmas. In addition, perfluorooctanesulfonate (PFOS) and related fluorochemicals, which are of current concern, were measured. Although anticipated, concentrations of PBDEs in the same samples were not yet determined. Through this study, a good approximation of the contamination level in Belgian human is given, allowing thus comparison with concentrations observed in other countries.

  10. Origin of metallic surface core-level shifts

    DEFF Research Database (Denmark)

    Aldén, Magnus; Skriver, Hans Lomholt; Abrikosov, I. A.

    1995-01-01

    The unique property of the open 4f energy shell in the lanthanide metals is used to show that the initial-state energy shift gives an insufficient description of surface core-level shifts. Instead a treatment, which fully includes the final-state screening, account for the experimentally observed...

  11. The technique for determination of surface contamination by uranium on U3Si2-Al plate-type fuel elements

    International Nuclear Information System (INIS)

    Li Shulan; He Fengqi; Wang Qingheng; Han Jingquan

    1993-04-01

    The NDT method for determining the surface contamination by uranium on U 3 Si 2 -Al plate-type fuel elements, the process of standard specimen preparation and the graduation curve are described. The measurement results of U 3 Si 2 -Al plate-type fuel elements show that the alpha counting method to measure the surface contamination by uranium on fuel plate is more reliable. The UB-1 type surface contamination meter, which was recently developed, has many advantages such as high sensitivity to determine the uranium pollution, short time in measuring, convenience for operation, and the minimum detectable amount of uranium is 5 x 10 -10 g/cm 2 . The measuring device is controlled by a microcomputer. Besides data acquisition and processing, it has functions of statistics, output data on terminal or to printer and alarm. The procedures of measurement are fully automatic. All of these will meet the measuring needs in batch process

  12. Contribution of the surface contamination of uranium-materials on the quantitative analysis results by electron probe microbeam analysis

    International Nuclear Information System (INIS)

    Bonino, O.; Fournier, C.; Fucili, C.; Dugne, O.; Merlet, C.

    2000-01-01

    The analytical testing of uranium materials is necessary for quality research and development in nuclear industry applications (enrichment, safety studies, fuel, etc). Electron Probe Microbeam Analysis Wavelength Dispersive Spectrometry (EPMA-WDS) is a dependable non-destructive analytical technology. The characteristic X-ray signal is measured to identify and quantify the sample components, and the analyzed volume is about one micron cube. The surface contamination of uranium materials modifies and contributes to the quantitative analysis results of EPMA-WDS. This contribution is not representative of the bulk. A thin oxidized layer appears in the first instants after preparation (burnishing, cleaning) as well as a carbon contamination layer, due to metallographic preparation and carbon cracking under the impact of the electron probe. Several analytical difficulties subsequently arise, including an overlapping line between the carbon Ka ray and the Uranium U NIVOVI ray. Sensitivity and accuracy of the quantification of light elements like carbon and oxygen are also reduced by the presence of uranium. The aim of this study was to improve the accuracy of quantitative analysis on uranium materials by EPMA-WDS by taking account of the contribution of surface contamination. The first part of this paper is devoted to the study of the contaminated surface of the uranium materials U, UFe 2 and U 6 Fe a few hours after preparation. These oxidation conditions are selected so as to reproduce the same contamination surfaces occurring in microprobe analytical conditions. Surface characterization techniques were SIMS and Auger spectroscopy. The contaminated surfaces are shown. They consist of successive layers: a carbon layer, an oxidized iron layer, followed by an iron depletion layer (only in UFe 2 and U 6 Fe), and a ternary oxide layer (U-Fe-O for UFe 2 et U 6 Fe and UO 2+x for uranium). The second part of the paper addresses the estimation of the errors in quantitative

  13. Estimation of Potential Population Level Effects of Contaminants on Wildlife; FINAL

    International Nuclear Information System (INIS)

    Loar, J.M.

    2001-01-01

    The objective of this project is to provide DOE with improved methods to assess risks from contaminants to wildlife populations. The current approach for wildlife risk assessment consists of comparison of contaminant exposure estimates for individual animals to literature-derived toxicity test endpoints. These test endpoints are assumed to estimate thresholds for population-level effects. Moreover, species sensitivities to contaminants is one of several criteria to be considered when selecting assessment endpoints (EPA 1997 and 1998), yet data on the sensitivities of many birds and mammals are lacking. The uncertainties associated with this approach are considerable. First, because toxicity data are not available for most potential wildlife endpoint species, extrapolation of toxicity data from test species to the species of interest is required. There is no consensus on the most appropriate extrapolation method. Second, toxicity data are represented as statistical measures (e.g., NOAEL s or LOAELs) that provide no information on the nature or magnitude of effects. The level of effect is an artifact of the replication and dosing regime employed, and does not indicate how effects might increase with increasing exposure. Consequently, slight exceedance of a LOAEL is not distinguished from greatly exceeding it. Third, the relationship of toxic effects on individuals to effects on populations is poorly estimated by existing methods. It is assumed that if the exposure of individuals exceeds levels associated with impaired reproduction, then population level effects are likely. Uncertainty associated with this assumption is large because depending on the reproductive strategy of a given species, comparable levels of reproductive impairment may result in dramatically different population-level responses. This project included several tasks to address these problems: (1) investigation of the validity of the current allometric scaling approach for interspecies extrapolation

  14. Mechanisms for surface contamination of soils and bottom sediments in the Shagan River zone within former Semipalatinsk Nuclear Test Site.

    Science.gov (United States)

    Aidarkhanov, A O; Lukashenko, S N; Lyakhova, O N; Subbotin, S B; Yakovenko, Yu Yu; Genova, S V; Aidarkhanova, A K

    2013-10-01

    The Shagan River is the only surface watercourse within the former Semipalatinsk Test Site (STS). Research in the valley of the Shagan River was carried out to study the possible migration of artificial radionuclides with surface waters over considerable distances, with the possibility these radionuclides may have entered the Irtysh River. The investigations revealed that radioactive contamination of soil was primarily caused by the first underground nuclear test with soil outburst conducted at the "Balapan" site in Borehole 1004. The surface nuclear tests carried out at the "Experimental Field" site and global fallout made insignificant contributions to contamination. The most polluted is the area in the immediate vicinity of the "Atomic" Lake crater. Contamination at the site is spatial. The total area of contamination is limited to 10-12 km from the crater piles. The ratio of plutonium isotopes was useful to determine the source of soil contamination. There was virtual absence of artificial radionuclide migration with surface waters, and possible cross-border transfer of radionuclides with the waters of Shagan and Irtysh rivers was not confirmed. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Anatomic-physiological schema of the gastrointestinal tract, to be taken in account in determining the levels of radioactive contamination

    International Nuclear Information System (INIS)

    Fabry, C.

    1964-01-01

    Anatomical and physiological data of the gastrointestinal tract of adults and children were summarized in a standard schema, to be used in calculating the levels of radioactive contamination, in the food chain. (author) [fr

  16. Functional gene array-based analysis of microbial community structure in groundwaters with a gradient of contaminant levels

    Energy Technology Data Exchange (ETDEWEB)

    Waldron, P.J.; Wu, L.; Van Nostrand, J.D.; Schadt, C.W.; Watson, D.B.; Jardine, P.M.; Palumbo, A.V.; Hazen, T.C.; Zhou, J.

    2009-06-15

    To understand how contaminants affect microbial community diversity, heterogeneity, and functional structure, six groundwater monitoring wells from the Field Research Center of the U.S. Department of Energy Environmental Remediation Science Program (ERSP; Oak Ridge, TN), with a wide range of pH, nitrate, and heavy metal contamination were investigated. DNA from the groundwater community was analyzed with a functional gene array containing 2006 probes to detect genes involved in metal resistance, sulfate reduction, organic contaminant degradation, and carbon and nitrogen cycling. Microbial diversity decreased in relation to the contamination levels of the wells. Highly contaminated wells had lower gene diversity but greater signal intensity than the pristine well. The microbial composition was heterogeneous, with 17-70% overlap between different wells. Metal-resistant and metal-reducing microorganisms were detected in both contaminated and pristine wells, suggesting the potential for successful bioremediation of metal-contaminated groundwaters. In addition, results of Mantel tests and canonical correspondence analysis indicate that nitrate, sulfate, pH, uranium, and technetium have a significant (p < 0.05) effect on microbial community structure. This study provides an overall picture of microbial community structure in contaminated environments with functional gene arrays by showing that diversity and heterogeneity can vary greatly in relation to contamination.

  17. GWSCREEN: A semi-analytical model for assessment of the groundwater pathway from surface or buried contamination: Version 2.0 theory and user's manual

    International Nuclear Information System (INIS)

    Rood, A.S.

    1993-06-01

    GWSCREEN was developed for assessment of the groundwater pathway from leaching of radioactive and non radioactive substances from surface or buried sources. The code was designed for implementation in the Track I and Track II assessment of CERCLA (Comprehensive Environmental Response, Compensation and Liability Act) sites identified as low probability hazard at the Idaho National Engineering Laboratory (DOE, 1992). The code calculates the limiting soil concentration such that, after leaching and transport to the aquifer, regulatory contaminant levels in groundwater are not exceeded. The code uses a mass conservation approach to model three processes: contaminant release from a source volume, contaminant transport in the unsaturated zone, and contaminant transport in the saturated zone. The source model considers the sorptive properties and solubility of the contaminant. Transport in the unsaturated zone is described by a plug flow model. Transport in the saturated zone is calculated with a semi-analytical solution to the advection dispersion equation in groundwater. In Version 2.0, GWSCREEN has incorporated an additional source model to calculate the impacts to groundwater resulting from the release to percolation ponds. In addition, transport of radioactive progeny has also been incorporated. GWSCREEN has shown comparable results when compared against other codes using similar algorithms and techniques. This code was designed for assessment and screening of the groundwater pathway when field data is limited. It was not intended to be a predictive tool

  18. GWSCREEN: A semi-analytical model for assessment of the groundwater pathway from surface or buried contamination: Version 2.0 theory and user`s manual

    Energy Technology Data Exchange (ETDEWEB)

    Rood, A.S.

    1993-06-01

    GWSCREEN was developed for assessment of the groundwater pathway from leaching of radioactive and non radioactive substances from surface or buried sources. The code was designed for implementation in the Track I and Track II assessment of CERCLA (Comprehensive Environmental Response, Compensation and Liability Act) sites identified as low probability hazard at the Idaho National Engineering Laboratory (DOE, 1992). The code calculates the limiting soil concentration such that, after leaching and transport to the aquifer, regulatory contaminant levels in groundwater are not exceeded. The code uses a mass conservation approach to model three processes: contaminant release from a source volume, contaminant transport in the unsaturated zone, and contaminant transport in the saturated zone. The source model considers the sorptive properties and solubility of the contaminant. Transport in the unsaturated zone is described by a plug flow model. Transport in the saturated zone is calculated with a semi-analytical solution to the advection dispersion equation in groundwater. In Version 2.0, GWSCREEN has incorporated an additional source model to calculate the impacts to groundwater resulting from the release to percolation ponds. In addition, transport of radioactive progeny has also been incorporated. GWSCREEN has shown comparable results when compared against other codes using similar algorithms and techniques. This code was designed for assessment and screening of the groundwater pathway when field data is limited. It was not intended to be a predictive tool.

  19. Decommissioning of a hot cell with high levels of contamination. Experience during the Undressed of Workers

    International Nuclear Information System (INIS)

    Martinez, A.; Sancho, C.

    1998-01-01

    The object of this work is to show the radiological controls in decommissioning of the inner of the Base Cell of the Nuclear Facility of CIEMAT, IN-04 (Metallurgy Hot Cells) and the experience during the undressed of workers in decommissioning of this cell. The workers were equipped with one cotton overalls and one or two paper overalls of one-use. Also, when the radiation levels are high, the workers were equipped with leaded glasses and aprons. The protection equipment for internal contamination were autonomous and semi-autonomous respiratory equipment. Due to a high superficial contamination levels, two areas were established in order to proceed to the undressed of the workers when these concluded their work. The first area was a confined enclosure by joined to the hot cell, where an expert of the Radiation Protection Service (RPS), trained for it, take off the first paper overall and the first pair of gloves to the worker that come out the hot cells. The second area was at the exist of the Load Zone, where another expert of PRS, take off the second paper overall, the second pair of gloves and dislocated the pipe of air of the semi-autonomous respiratory equipment, to the worker that come out this zone. (Author)

  20. Contaminant risks from biosolids land application Contemporary organic contaminant levels in digested sewage sludge from five treatment plants in Greater Vancouver, British Columbia

    International Nuclear Information System (INIS)

    Bright, D.A.; Healey, N.

    2003-01-01

    The risks of organic contaminants in sewage sludges are evaluated. - This study examines the potential for environmental risks due to organic contaminants at sewage sludge application sites, and documents metals and various potential organic contaminants (volatile organics, chlorinated pesticides, PCBs, dioxins/furans, extractable petroleum hydrocarbons, PAHs, phenols, and others) in current production biosolids from five wastewater treatment plants (WWTPs) within the Greater Vancouver Regional District (GVRD). There has been greater focus in Europe, North America and elsewhere on metals accumulation in biosolids-amended soil than on organic substances, with the exception of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans. Another objective, therefore, was to evaluate the extent to which management of biosolids re-use based on metal/metalloid levels coincidentally minimizes environmental risks from organic contaminants. Historical-use contaminants such as chlorophenols, PCBs, and chlorinated pesticides were not detected at environmentally relevant concentrations in any of the 36 fresh biosolids samples, and appear to have virtually eliminated from sanitary collection system inputs. The few organic contaminants found in freshly produced biosolids samples that exhibited high concentrations relative to British Columbia and Canadian soil quality benchmarks included p-cresol, phenol, phenanthrene, pyrene, naphthalene, and heavy extractable petroleum hydrocarbons (HEPHs-nCl9-C34 effective carbon chain length). It was concluded that, with the exception of these petroleum hydrocarbon constituents or their microbial metabolites, the mixing of biosolids with uncontaminated soils during land application and based on the known metal concentrations in biosolids from the Greater Vancouver WWTPs investigated provides adequate protection against the environmental risks associated with organic substances such as dioxins and furans, phthalate esters, or volatile

  1. Detection of contaminated metallurgical scrap at borders: a proposal for an 'investigation level'

    International Nuclear Information System (INIS)

    Duftschmid, K.E.

    1999-01-01

    In 1995 the IAEA started a program to combat illicit trafficking in nuclear and other radioactive materials which includes the problem of cross-border movement of contaminated metallurgical scrap. A major activity in this program is the elaboration of a Safety Guide on 'Preventing, Detecting and Responding to Illicit Trafficking', co-sponsored by the World Customs Organization (WCO) and INTERPOL. The guide will provide advice to the Member States, in particular on technical and administrative procedures for detection of radioactive materials at borders. Radiation monitoring systems for contaminated scrap metals have been successfully used in steel plants and larger scrap yards since several years and suitable products are on the market today. Using sophisticated software and dynamic scanning techniques such systems allow for detection of an artificial increase in radiation background level as low as by 20%, even if the natural background signal is substantially suppressed by the vehicle itself entering the monitor. However, the measurement conditions at borders are essentially different from those in plants. Large traffic crossing major borders limits the time for detection and response to a few seconds and multiple checks are nearly impractical. Shielded radioactive sources - even of high activity - which are deeply buried in scrap, cannot be detected without unloading the vehicle, a procedure generally ruled out at borders. Highly sensitive monitoring systems necessarily cause frequent false alarms or nuisance alarms due to innocent radioactive materials such as naturally occurring radioactivity e.g. in fertilizers, scale in pipes used in the oil industry or medical radioisotopes. A particular, rather frequent problem is the unnecessary reject of scrap transports on borders due to the inherent low level contamination of steel with 60 Co, even in sheet metal used for lorries or railroad cars. Such contamination can easily be caused by the routine method to control

  2. Organization of work for prevention of propagation of radioactive contamination, for decontamination of the premise surfaces and individual protective means in case of radiation accident

    International Nuclear Information System (INIS)

    Klochkov, V.N.; Vas'kin, A.G.; Filatova, V.M.

    1995-01-01

    Radiation accident results in radioactive contamination of the surface, clothes and other property. If proper measures are taken, it will prevent propagation of contamination. Decontamination of surfaces - is a complicated and tedious process. The paper has examined the measures of organization and technical aspects of prevention of propagation of radioactive contamination. Methods of decontamination of internal surfaces of premises are demonstrated, organization of the individual protective means is determined. 9 refs

  3. Organochlorine contaminant and retinoid levels in blubber of common dolphins (Delphinus delphis) off northwestern Spain

    International Nuclear Information System (INIS)

    Tornero, Victoria; Borrell, Assumpcio; Aguilar, Alex; Forcada, Jaume; Lockyer, Christina

    2006-01-01

    The effect of age, sex, nutritive condition and organochlorine concentration on blubber retinoid concentrations was examined in 74 common dolphins incidentally caught off northwestern Spain. Age and blubber lipid content were strong determinants of the retinoid concentrations in males, while these variables did not account for the variation found in females. Retinoids were positively correlated with organochlorines in males and negatively in females. However, pollution levels were moderate and likely to be below threshold levels above that a toxicological response is to be expected. Thus, a cause-effect relationship between organochlorine and retinoid concentrations could not be properly established, and the observed correlation may be the result of an independent association of the two variables with age. Further research on the influence of the best predictor variables on retinoid dynamics is required to implement the use of retinoids as biomarkers of pollutant exposure in cetaceans. - Organochlorine contaminants and retinoids in common dolphins

  4. Contaminant transport modelling in tidal influenced water body for low level liquid waste discharge out

    International Nuclear Information System (INIS)

    Singh, Sanjay; Naidu, Velamala Simhadri

    2018-01-01

    Low level liquid waste is generated from nuclear reactor operation and reprocessing of spent fuel. This waste is discharged into the water body after removing bulk of its radioactivity. Dispersion of contaminant mainly depends on location of outfall and hydrodynamics of water body. For radiological impact assessment, in most of the analytical formulations, source term is taken as continuous release. However, this may not be always true as the water level is influenced by tidal movement and the selected outfall may come under intertidal zone in due course of the tidal cycle. To understand these phenomena, a case study has been carried out to evaluate hydrodynamic characteristics and dilution potential of outfall located in inter-tidal zone using numerical modelling

  5. Evaluation of the homogeneity of reference flat sources used in calibration of surface contamination monitors

    International Nuclear Information System (INIS)

    Silva Junior, I.A.; Xavier, M.; Siqueira, P.T.D.; Potiens, M.P.A.

    2014-01-01

    The aim of this study was to re-evaluate the uniformity of the wide area reference sources of the Calibration Laboratory of Instruments (LCI-IPEN) used in the calibration of surface contamination monitors, according the recommendations of the ISO 8769 standard and the NRPB. In this work used six wide area reference sources of 150 cm 2 of 241 Am, 14 C, 36 Cl, 137 Cs, 90 Sr+ 90 Y and 99 Tc with reference dates between 1996 and 1997 and three sources of 100 cm 2 of 14 C, 137 Cs and 60 Co were used with reference dates 2007. Measurements were performed with a radiation monitor of the Thermo, model FH40GX with a pancake probe, model FHZ732GM. We also made several models on paper with the objective of define each measurement position and an aluminum plate with a square hole (6.25 cm 2 ) in its center, allowing the passage of the radiation only through the hole. Each wide area reference source was positioned in setup and measurements were performed in order to cover the entire surface of the source. The values of the uniformity obtained partially confirm previous data obtained in another study conducted by LCI-IPEN, showing that some wide area reference sources 150 cm 2 in disagree with ISO 8769. In the former work, just the source of 241 Am (7.3%) was within the range specified by the standard, now have sources of 241 Am (5.7%), 137 Cs (8.8%), 90 Sr+ 9 '0Y (8, 8%) and 99 Tc (9.2%) with values within the specified uniformity. The sources of 14 C (53.3%) and 36 Cl (16.6%) were outside the specified. The wide area reference sources of 100 cm 2 , show disagreement in values of uniformity of the sources 14 C (46.7%) and 60 Co (10.4%). The values of the uniformity of the wide area reference sources show that some fonts can not be used in calibrations, because not in accordance with the value of uniformity specified in ISO 8769:2010, this is a conditions to believe a laboratory according to ISO 17025, show the laboratory performs its services with a high quality. The

  6. Evaluation of the contribution of contamination of radiotherapy room surfaces in the measure of exposure rate of radioiodine therapy patients

    International Nuclear Information System (INIS)

    Campos, Rafael Ferreira

    2015-01-01

    The contamination of radiotherapy room surfaces is significant and the measures of patient exposure rate are held on the fourth dependencies, relevant questions are raised: the background radiation of the room stay high due to surface contamination, may interfere with the rate of patient exposure at the time of its release? The monitoring site is important to determine whether the patient will be released? The value of the deal activity and the clinical condition of the patient may increase the contamination, influencing the monitoring results? This paper aims to conduct a quantitative analysis of surface contamination of the contribution of therapeutic room at the time is monitored exposure rate from inpatient. Measurements were made regarding the hospitalization of 32 patients with different doses administered activity, age and of both genders. The measurements were performed in the therapeutic rooms at the hospital Brotherhood Santa Casa de Misericordia de Sao Paulo. Exposure rate measurements were performed at the center of the room at 1 meter of the patient on the day of its release. After his release and prior to decontamination, measurements were performed at predetermined landmarks within the therapeutic room. The results revealed that on average background radiation, high due to surface contamination contributes only 2% of the patient dose rate. It can be considered that even with influence of contamination of surfaces, this is insignificant to determine if the patient may or may not be released. This study suggests that the site in which monitoring occurs exposure rate of the patient should not be decisive for liberation thereof. (author)

  7. Assessment of lead, cadmium, and zinc contamination of roadside soils, surface films, and vegetables in Kampala City, Uganda

    International Nuclear Information System (INIS)

    Nabulo, Grace; Oryem-Origa, Hannington; Diamond, Miriam

    2006-01-01

    The relationship between traffic density and trace metal concentrations in roadside soils, surface films, and a selected vegetable weed, Amaranthus dubius Mart. Ex Thell., was determined in 11 farming sites along major highways around Kampala City in Uganda. Surface soil, atmospherically deposited surface films on windows, and leaves of Amaranthus dubius were sampled at known distances from the roads and analyzed for lead (Pb), zinc (Zn), and cadmium (Cd) using flame atomic absorption spectrophotometry. Atmospherically deposited trace metal particulates were sampled using window glass as an inert, passive collector. Total trace metal concentrations in soils ranged from 30.0±2.3 to 64.6±11.7 mg/kg Pb, 78.4±18.4 to 265.6±63.2 mg/kg Zn, and 0.8±0.13 to 1.40±0.16 mg/kg Cd. Total trace metal levels in soil decreased rapidly with distance from the road. Total Pb decreased with distance up to 30 m from the road, where it reached a background soil concentration of 28 mg/kg dry weight. The study found background values of 50 and 1.4 mg/kg for Zn and Cd in roadside soils, respectively. Similarly, Pb concentration in Amaranthus dubius leaves decreased with increasing distance from the road edge. The dominant pathway for Pb contamination was from atmospheric deposition, which was consistent with Pb concentrations in surface films. The mean Pb concentrations in leaves of roadside crops were higher than those in their respective roots, with the highest leaf-to-root ratio observed in the Brassica oleraceae acephala group. The lowest Pb and Zn concentrations were found in the fruit compared to the leaves of the same crops. Leaves of roadside vegetables were therefore considered a potential source of heavy metal contamination to farmers and consumers in urban areas. It is recommended that leafy vegetables should be grown 30 m from roads in high-traffic, urban areas

  8. Mercury contamination in human hair and fish from Cambodia: levels, specific accumulation and risk assessment

    International Nuclear Information System (INIS)

    Agusa, Tetsuro; Kunito, Takashi; Iwata, Hisato; Monirith, In; Tana, Touch Seang; Subramanian, Annamalai;