WorldWideScience

Sample records for suprathermal ion detector

  1. Suprathermal ion transport in turbulent magnetized plasmas

    International Nuclear Information System (INIS)

    Bovet, A. D.

    2015-01-01

    Suprathermal ions, which have an energy greater than the quasi-Maxwellian background plasma temperature, are present in many laboratory and astrophysical plasmas. In fusion devices, they are generated by the fusion reactions and auxiliary heating. Controlling their transport is essential for the success of future fusion devices that could provide a clean, safe and abundant source of electric power to our society. In space, suprathermal ions include energetic solar particles and cosmic rays. The understanding of the acceleration and transport mechanisms of these particles is still incomplete. Basic plasma devices allow detailed measurements that are not accessible in astrophysical and fusion plasmas, due to the difficulty to access the former and the high temperatures of the latter. The basic toroidal device TORPEX offers an easy access for diagnostics, well characterized plasma scenarios and validated numerical simulations of its turbulence dynamics, making it the ideal platform for the investigation of suprathermal ion transport. This Thesis presents three-dimensional measurements of a suprathermal ion beam injected in turbulent TORPEX plasmas. The combination of uniquely resolved measurements and first principle numerical simulations reveals the general non-diffusive nature of the suprathermal ion transport. A precise characterization of their transport regime shows that, depending on their energies, suprathermal ions can experience either a super diffusive transport or a subdiffusive transport in the same background turbulence. The transport character is determined by the interaction of the suprathermal ion orbits with the turbulent plasma structures, which in turn depends on the ratio between the ion energy and the background plasma temperature. Time-resolved measurements reveal a clear difference in the intermittency of suprathermal ions time-traces depending on the transport regime they experience. Conditionally averaged measurements uncover the influence of

  2. MAVEN SupraThermal and Thermal Ion Compostion (STATIC) Instrument

    Science.gov (United States)

    McFadden, J. P.; Kortmann, O.; Curtis, D.; Dalton, G.; Johnson, G.; Abiad, R.; Sterling, R.; Hatch, K.; Berg, P.; Tiu, C.; Gordon, D.; Heavner, S.; Robinson, M.; Marckwordt, M.; Lin, R.; Jakosky, B.

    2015-12-01

    The MAVEN SupraThermal And Thermal Ion Compostion (STATIC) instrument is designed to measure the ion composition and distribution function of the cold Martian ionosphere, the heated suprathermal tail of this plasma in the upper ionosphere, and the pickup ions accelerated by solar wind electric fields. STATIC operates over an energy range of 0.1 eV up to 30 keV, with a base time resolution of 4 seconds. The instrument consists of a toroidal "top hat" electrostatic analyzer with a 360° × 90° field-of-view, combined with a time-of-flight (TOF) velocity analyzer with 22.5° resolution in the detection plane. The TOF combines a -15 kV acceleration voltage with ultra-thin carbon foils to resolve H+, He^{++}, He+, O+, O2+, and CO2+ ions. Secondary electrons from carbon foils are detected by microchannel plate detectors and binned into a variety of data products with varying energy, mass, angle, and time resolution. To prevent detector saturation when measuring cold ram ions at periapsis (˜10^{1 1} eV/cm2 s sr eV), while maintaining adequate sensitivity to resolve tenuous pickup ions at apoapsis (˜103 eV/cm2 s sr eV), the sensor includes both mechanical and electrostatic attenuators that increase the dynamic range by a factor of 103. This paper describes the instrument hardware, including several innovative improvements over previous TOF sensors, the ground calibrations of the sensor, the data products generated by the experiment, and some early measurements during cruise phase to Mars.

  3. PIC simulation of the electron-ion collision effects on suprathermal electrons

    International Nuclear Information System (INIS)

    Wu Yanqing; Han Shensheng

    2000-01-01

    The generation and transportation of suprathermal electrons are important to both traditional ICF scheme and 'Fast Ignition' scheme. The author discusses the effects of electron-ion collision on the generation and transportation of the suprathermal electrons by parametric instability. It indicates that the weak electron-ion term in the PIC simulation results in the enhancement of the collisional absorption and increase of the hot electron temperature and reduction in the maximum electrostatic field amplitude while wave breaking. Therefore the energy and distribution of the suprathermal electrons are changed. They are distributed more close to the phase velocity of the electrostatic wave than the case without electron-ion collision term. The electron-ion collision enhances the self-consistent field and impedes the suprathermal electron transportation. These factors also reduce the suprathermal electron energy. In addition, the authors discuss the effect of initial condition on PIC simulation to ensure that the results are correct

  4. Observations of thermal and suprathermal tail ions from WIND

    Science.gov (United States)

    Randol, B. M.; Christian, E. R.; Wilson, L. B., III

    2016-12-01

    The velocity distribution function (VDF) of solar wind protons (as well as other ion populations) is comprised of a thermal Maxwellian core and an accelerated suprathermal tail, beginning at around 1 keV in the frame co-moving with solar wind bulk velocity. The form of the suprathermal tail is a power law in phase space density, f, vs. speed, v, such that f / vγ, where γ is the power law index. This commonly observed index is of particular interest because no traditional theory predicts its existence. We need more data in order to test these theories. The general shape is of interest because it is kappa-like. We show combined observations from three different instruments on the WIND spacecraft: 3DP/PLSP, STICS, and 3DP/SST/Open. These data stretch from 102 to 107 eV in energy, encompassing both the thermal and suprathermal proton populations. We show further evidence for this kappa-like distribution and report on our progress on fitting of empirical functions to these data.

  5. Interaction of supra-thermal ions with turbulence in a magnetized toroidal plasma

    International Nuclear Information System (INIS)

    Plyushchev, G.

    2009-01-01

    This thesis addresses the interaction of a supra-thermal ion beam with turbulence in the simple magnetized toroidal plasma of TORPEX. The first part of the Thesis deals with the ohmic assisted discharges on TORPEX. The aim of these discharges is the investigation of the open to closed magnetic field line transition. The relevant magnetic diagnostics were developed. Ohmic assisted discharges with a maximum plasma current up to 1 kA are routinely obtained. The equilibrium conditions on the vacuum magnetic field configuration were investigated. In the second part of the Thesis, the design of the fast ion source and detector are discussed. The accelerating electric field needed for the fast ion source was optimized. The fast ion source was constructed and commissioned. To detect the fast ions a specially designed gridded energy analyzer was used. The electron energy distribution function was obtained to demonstrate the efficiency of the detector. The experiments with the fast ion beam were conducted in different plasma regions of TORPEX. In the third part of the Thesis, numerical simulations are used to interpret the measured fast ion beam behavior. It is shown that a simple single particle equation of motion explains the beam behavior in the experiments in the absence of plasma. To explain the fast ion beam experiments with the plasma a turbulent electric field must be used. The model that takes into account this turbulent electrical field qualitatively explains the shape of the fast ion current density profile in the different plasma regions of TORPEX. The vertically elongated fast ion current density profiles are explained by a spread in the fast ion velocity distribution. The theoretically predicted radial fast ion beam spreading due to the turbulent electric field was observed in the experiment. (author)

  6. Investigation of the role of electron cyclotron resonance heating and magnetic configuration on the suprathermal ion population in the stellarator TJ-II using a luminescent probe

    Science.gov (United States)

    Martínez, M.; Zurro, B.; Baciero, A.; Jiménez-Rey, D.; Tribaldos, V.

    2018-02-01

    Numerous observation exist of a population of high energetic ions with energies well above the corresponding thermal values in plasmas generated by electron cyclotron resonance (ECR) heating in TJ-II stellarator and in other magnetically confined plasmas devices. In this work we study the impact of ECR heating different conditions (positions and powers) on fast ions escaping from plasmas in the TJ-II stellarator. For this study, an ion luminescent probe operated in counting mode is used to measure the energy distribution of suprathermal ions, in the range from 1 to 30 keV. It is observed that some suprathermal ions characteristics (such as temperature, particle and energy fluxes) are related directly with the gyrotron power and focus position of the heating beam in the plasma. Moreover, it is found that suprathermal ion characteristics vary during a magnetic configuration scan (performed along a single discharge). By investigating the suprathermal ions escaping from plasmas generated using two gyrotrons, one with fixed power and the other modulated (on/off) at low frequency (10 Hz), the de-confinement time of the suprathermal ions can be measured, which is of the order of a few milliseconds (power balance is used to understand the de-confinement times in terms of the interaction of suprathermal ions and plasma components. This model also can be used to interpret experimental results of energy loss due to suprathermal ions. Finally, observations of increases (peaks) in the population of escaping suprathermal ions, which are well localized at discrete energies, is documented, these peaks being observed in the energy distributions along a discharge.

  7. Suprathermal He2+ in the Earth's foreshock region

    International Nuclear Information System (INIS)

    Fuselier, S.A.; Thomsen, M.F.; Ipavich, F.M.; Schmidt, W.K.H.

    1995-01-01

    ISEE 1 and 2 H + and He 2+ observations upstream from the Earth's bow shock are used to investigate the origin of energetic (or diffuse) ion distributions. Diffuse ion distributions have energies from a few keV/e to > 100 keV/e and have near solar wind concentrations (i.e., an average of about 4% He 2+ ). These distributions may evolve from suprathermal ion distributions that have energies between 1 and a few keV/e. Upstream intervals were selected from the ISEE data to determine which suprathermal distributions have He 2+ concentrations similar to those of diffuse ion distributions. The type of distribution and the location in the foreshock were similar in all events studied. Two intervals that represent the results from this study are discussed in detail. The results suggest that diffuse ion distributions evolve from suprathermal distributions in the region upstream from the quasi-parallel bow shock. For He 2+ , the suprathermal distribution is a nongyrotropic partial ring beam and has characteristics consistent with specular reflection off the quasi-parallel bow shock. The suprathermal proton distributions associated with these He 2+ distributions are nongyrotropic partial ring beams or nearly gyrotropic ring beams also approximately consistent with specular reflection. The location in the quasi-parallel foreshock and the similarity of the suprathermal He 2+ and H + distributions suggest that these are the seed population for diffuse distributions in the foreshock region. 30 refs., 5 figs., 1 tab

  8. Effects of ionization and ion loss on dust ion- acoustic solitary waves in a collisional dusty plasma with suprathermal electrons

    Science.gov (United States)

    Tribeche, Mouloud; Mayout, Saliha

    2016-07-01

    The combined effects of ionization, ion loss and electron suprathermality on dust ion- acoustic solitary waves in a collisional dusty plasma are examined. Carrying out a small but finite amplitude analysis, a damped Korteweg- de Vries (dK-- dV) equation is derived. The damping term decreases with the increase of the spectral index and saturates for Maxwellian electrons. Choosing typical plasma parameters, the analytical approximate solution of the dK- dV equation is numerically analyzed. We first neglect the ionization and ion loss effects and account only for collisions to estimate the relative importance between these damping terms which can act concurrently. Interestingly, we found that as the suprathermal character of the electrons becomes important, the strength of the collisions related dissipation becomes more important and causes the DIA solitary wave amplitude to decay more rapidly. Moreover, the collisional damping may largely prevail over the ionization and ion loss related damping. The latter becomes more effective as the electrons evolve far away from their thermal equilibrium. Our results complement and provide new insights into previously published work on this problem.

  9. Effects of ionization and ion loss on dust ion-acoustic solitary waves in a collisional dusty plasma with suprathermal electrons

    Energy Technology Data Exchange (ETDEWEB)

    Mayout, Saliha; Gougam, Leila Ait [Faculty of Physics, Theoretical Physics Laboratory, Plasma Physics Group, University of Bab-Ezzouar, USTHB, B.P. 32, El Alia, Algiers 16111 (Algeria); Tribeche, Mouloud, E-mail: mouloudtribeche@yahoo.fr, E-mail: mtribeche@usthb.dz [Faculty of Physics, Theoretical Physics Laboratory, Plasma Physics Group, University of Bab-Ezzouar, USTHB, B.P. 32, El Alia, Algiers 16111 (Algeria); Algerian Academy of Sciences and Technologies, Algiers (Algeria)

    2016-03-15

    The combined effects of ionization, ion loss, and electron suprathermality on dust ion-acoustic solitary waves in a collisional dusty plasma are examined. Carrying out a small but finite amplitude analysis, a damped Korteweg-de Vries (dK–dV) equation is derived. The damping term decreases with the increase of the spectral index and saturates for Maxwellian electrons. Choosing typical plasma parameters, the analytical approximate solution of the dK-dV equation is numerically analyzed. We first neglect the ionization and ion loss effects and account only for collisions to estimate the relative importance between these damping terms which can act concurrently. Interestingly, we found that as the suprathermal character of the electrons becomes important, the strength of the collisions related dissipation becomes more important and causes the dust ion-acoustic solitary wave amplitude to decay more rapidly. Moreover, the collisional damping may largely prevail over the ionization and ion loss related damping. The latter becomes more effective as the electrons evolve far away from their thermal equilibrium. Our results complement and provide new insights into previously published work on this problem.

  10. Effects of ionization and ion loss on dust ion-acoustic solitary waves in a collisional dusty plasma with suprathermal electrons

    International Nuclear Information System (INIS)

    Mayout, Saliha; Gougam, Leila Ait; Tribeche, Mouloud

    2016-01-01

    The combined effects of ionization, ion loss, and electron suprathermality on dust ion-acoustic solitary waves in a collisional dusty plasma are examined. Carrying out a small but finite amplitude analysis, a damped Korteweg-de Vries (dK–dV) equation is derived. The damping term decreases with the increase of the spectral index and saturates for Maxwellian electrons. Choosing typical plasma parameters, the analytical approximate solution of the dK-dV equation is numerically analyzed. We first neglect the ionization and ion loss effects and account only for collisions to estimate the relative importance between these damping terms which can act concurrently. Interestingly, we found that as the suprathermal character of the electrons becomes important, the strength of the collisions related dissipation becomes more important and causes the dust ion-acoustic solitary wave amplitude to decay more rapidly. Moreover, the collisional damping may largely prevail over the ionization and ion loss related damping. The latter becomes more effective as the electrons evolve far away from their thermal equilibrium. Our results complement and provide new insights into previously published work on this problem.

  11. Effect of ion suprathermality on arbitrary amplitude dust acoustic waves in a charge varying dusty plasma

    International Nuclear Information System (INIS)

    Tribeche, Mouloud; Mayout, Saliha; Amour, Rabia

    2009-01-01

    Arbitrary amplitude dust acoustic waves in a high energy-tail ion distribution are investigated. The effects of charge variation and ion suprathermality on the large amplitude dust acoustic (DA) soliton are then considered. The correct suprathermal ion charging current is rederived based on the orbit motion limited approach. In the adiabatic case, the variable dust charge is expressed in terms of the Lambert function and we take advantage of this transcendental function to show the existence of rarefactive variable charge DA solitons involving cusped density humps. The dust charge variation leads to an additional enlargement of the DA soliton, which is less pronounced as the ions evolve far away from Maxwell-Boltzmann distribution. In the nonadiabatic case, the dust charge fluctuation may provide an alternate physical mechanism causing anomalous dissipation the strength of which becomes important and may prevail over that of dispersion as the ion spectral index κ increases. Our results may provide an explanation for the strong spiky waveforms observed in auroral electric field measurements by Ergun et al.[Geophys. Res. Lett. 25, 2025 (1998)].

  12. Suprathermal He{sup 2+} in the Earth`s foreshock region

    Energy Technology Data Exchange (ETDEWEB)

    Fuselier, S.A. [Lockheed Palo Alto Research Lab., CA (United States); Thomsen, M.F. [Los Alamos National Lab., NM (United States); Ipavich, F.M. [Univ. of Maryland, College Park, MD (United States); Schmidt, W.K.H. [Max-Planck-Institut fuer Aeronomie, Katlenburg-Lindau (Germany)

    1995-09-01

    ISEE 1 and 2 H{sup +} and He{sup 2+} observations upstream from the Earth`s bow shock are used to investigate the origin of energetic (or diffuse) ion distributions. Diffuse ion distributions have energies from a few keV/e to > 100 keV/e and have near solar wind concentrations (i.e., an average of about 4% He{sup 2+}). These distributions may evolve from suprathermal ion distributions that have energies between 1 and a few keV/e. Upstream intervals were selected from the ISEE data to determine which suprathermal distributions have He{sup 2+} concentrations similar to those of diffuse ion distributions. The type of distribution and the location in the foreshock were similar in all events studied. Two intervals that represent the results from this study are discussed in detail. The results suggest that diffuse ion distributions evolve from suprathermal distributions in the region upstream from the quasi-parallel bow shock. For He{sup 2+}, the suprathermal distribution is a nongyrotropic partial ring beam and has characteristics consistent with specular reflection off the quasi-parallel bow shock. The suprathermal proton distributions associated with these He{sup 2+} distributions are nongyrotropic partial ring beams or nearly gyrotropic ring beams also approximately consistent with specular reflection. The location in the quasi-parallel foreshock and the similarity of the suprathermal He{sup 2+} and H{sup +} distributions suggest that these are the seed population for diffuse distributions in the foreshock region. 30 refs., 5 figs., 1 tab.

  13. Effects of toroidal field ripple on suprathermal ions in tokamak plasmas

    International Nuclear Information System (INIS)

    Goldston, R.J.; Towner, H.H.

    1980-02-01

    Analytic calculations of three important effects of toroidal field ripple on suprathermal ions in tokamak plasmas are presented. In the first process, collisional ripple-trapping, beam ions become trapped in local magnetic wells near their banana tips due to pitch-angle scattering as they traverse the ripple on barely unripple-trapped orbits. In the second process, collisionless ripple-trapping, near-perpendicular untrapped ions are captured (again near a banana tip) due to their finite orbits, which carry them out into regions of higher ripple. In the third process, banana-drift diffusion, fast-ion banana orbits fail to close precisely, due to a ripple-induced variable lingering period near the banana tips. These three mechanisms lead to substantial radial transport of banana-trapped, neutral-beam-injected ions when the quantity α* identical with epsilon/sin theta/Nqdelta is of order unity or smaller

  14. Effects of toroidal field ripple on suprathermal ions in tokamak plasmas

    International Nuclear Information System (INIS)

    Goldston, R.J.; Towner, H.H.

    1981-01-01

    Analytic calculations of three important effects of toroidal field ripple on suprathermal ions in tokamak plasmas are presented. In the first process, collisional ripple-trapping, ions become trapped in local magnetic wells near their banana tips owing to pitch-angle scattering as they traverse the ripple on barely unripple-trapped orbits. In the second process, collisionless ripple-trapping, ions are captured (again near a banana tip) owing to their finite orbits, which carry them out into regions of higher ripple. In the third process, banana-drift diffusion, fast-ion banana orbits fail to close precisely, due to a ripple-induced 'variable lingering period' near the banana tips. These three mechanisms lead to substantial radial transport of banana-trapped, neutral-beam-injected ions when the quantity α* is identical with epsilonsinthetaNqdelta is of order unity or smaller. (author)

  15. Discovery of Suprathermal Fe+ in and near Earth's Magnetosphere

    Science.gov (United States)

    Christon, S. P.; Hamilton, D. C.; Plane, J. M. C.; Mitchell, D. G.; Grebowsky, J. M.; Spjeldvik, W. N.; Nylund, S. R.

    2017-12-01

    Suprathermal (87-212 keV/e) singly charged iron, Fe+, has been observed in and near Earth's equatorial magnetosphere using long-term ( 21 years) Geotail/STICS ion composition data. Fe+ is rare compared to dominant suprathermal solar wind and ionospheric origin heavy ions. Earth's suprathermal Fe+ appears to be positively associated with both geomagnetic and solar activity. Three candidate lower-energy sources are examined for relevance: ionospheric outflow of Fe+ escaped from ion layers altitude, charge exchange of nominal solar wind Fe+≥7, and/or solar wind transported inner source pickup Fe+ (likely formed by solar wind Fe+≥7 interaction with near sun interplanetary dust particles, IDPs). Semi-permanent ionospheric Fe+ layers form near 100 km altitude from the tons of IDPs entering Earth's atmosphere daily. Fe+ scattered from these layers is observed up to 1000 km altitude, likely escaping in strong ionospheric outflows. Using 26% of STICS's magnetosphere-dominated data at low-to-moderate geomagnetic activity levels, we demonstrate that solar wind Fe charge exchange secondaries are not an obvious Fe+ source then. Earth flyby and cruise data from Cassini/CHEMS, a nearly identical instrument, show that inner source pickup Fe+ is likely not important at suprathermal energies. Therefore, lacking any other candidate sources, it appears that ionospheric Fe+ constitutes at least an important portion of Earth's suprathermal Fe+, comparable to observations at Saturn where ionospheric origin suprathermal Fe+ has also been observed.

  16. Discovery of Suprathermal Ionospheric Origin Fe+ in and Near Earth's Magnetosphere

    Science.gov (United States)

    Christon, S. P.; Hamilton, D. C.; Plane, J. M. C.; Mitchell, D. G.; Grebowsky, J. M.; Spjeldvik, W. N.; Nylund, S. R.

    2017-11-01

    Suprathermal (87-212 keV/e) singly charged iron, Fe+, has been discovered in and near Earth's 9-30 RE equatorial magnetosphere using 21 years of Geotail STICS (suprathermal ion composition spectrometer) data. Its detection is enhanced during higher geomagnetic and solar activity levels. Fe+, rare compared to dominant suprathermal solar wind and ionospheric origin heavy ions, might derive from one or all three candidate lower-energy sources: (a) ionospheric outflow of Fe+ escaped from ion layers near 100 km altitude, (b) charge exchange of nominal solar wind iron, Fe+≥7, in Earth's exosphere, or (c) inner source pickup Fe+ carried by the solar wind, likely formed by solar wind Fe interaction with near-Sun interplanetary dust particles. Earth's semipermanent ionospheric Fe+ layers derive from tons of interplanetary dust particles entering Earth's atmosphere daily, and Fe+ scattered from these layers is observed up to 1000 km altitude, likely escaping in strong ionospheric outflows. Using 26% of STICS's magnetosphere-dominated data when possible Fe+2 ions are not masked by other ions, we demonstrate that solar wind Fe charge exchange secondaries are not an obvious Fe+ source. Contemporaneous Earth flyby and cruise data from charge-energy-mass spectrometer on the Cassini spacecraft, a functionally identical instrument, show that inner source pickup Fe+ is likely not important at suprathermal energies. Consequently, we suggest that ionospheric Fe+ constitutes at least a significant portion of Earth's suprathermal Fe+, comparable to the situation at Saturn where suprathermal Fe+ is also likely of ionospheric origin.

  17. Suprathermal electron environment of comet 67P/Churyumov-Gerasimenko: Observations from the Rosetta Ion and Electron Sensor

    Science.gov (United States)

    Clark, G.; Broiles, T. W.; Burch, J. L.; Collinson, G. A.; Cravens, T.; Frahm, R. A.; Goldstein, J.; Goldstein, R.; Mandt, K.; Mokashi, P.; Samara, M.; Pollock, C. J.

    2015-11-01

    Context. The Rosetta spacecraft is currently escorting comet 67P/Churyumov-Gerasimenko until its perihelion approach at 1.2 AU. This mission has provided unprecedented views into the interaction of the solar wind and the comet as a function of heliocentric distance. Aims: We study the interaction of the solar wind and comet at large heliocentric distances (>2 AU) using data from the Rosetta Plasma Consortium Ion and Electron Sensor (RPC-IES). From this we gain insight into the suprathermal electron distribution, which plays an important role in electron-neutral chemistry and dust grain charging. Methods: Electron velocity distribution functions observed by IES fit to functions used to previously characterize the suprathermal electrons at comets and interplanetary shocks. We used the fitting results and searched for trends as a function of cometocentric and heliocentric distance. Results: We find that interaction of the solar wind with this comet is highly turbulent and stronger than expected based on historical studies, especially for this weakly outgassing comet. The presence of highly dynamical suprathermal electrons is consistent with observations of comets (e.g., Giacobinni-Zinner, Grigg-Skjellerup) near 1 AU with higher outgassing rates. However, comet 67P/Churyumov-Gerasimenko is much farther from the Sun and appears to lack an upstream bow shock. Conclusions: The mass loading process, which likely is the cause of these processes, plays a stronger role at large distances from the Sun than previously expected. We discuss the possible mechanisms that most likely are responsible for this acceleration: heating by waves generated by the pick-up ion instability, and the admixture of cometary photoelectrons.

  18. Development and performance of a suprathermal electron spectrometer to study auroral precipitations

    Energy Technology Data Exchange (ETDEWEB)

    Ogasawara, Keiichi, E-mail: kogasawara@swri.edu; Stange, Jason L.; Trevino, John A.; Webster, James [Southwest Research Institute, 6220 Culebra Road, San Antonio, Texas 78238 (United States); Grubbs, Guy [University of Texas at San Antonio, One UTSA circle, San Antonio, Texas 78249 (United States); Goddard Space Flight Center, National Aeronautics and Space Administration, 8800 Greenbelt Rd, Greenbelt, Maryland 20771 (United States); Michell, Robert G.; Samara, Marilia [Goddard Space Flight Center, National Aeronautics and Space Administration, 8800 Greenbelt Rd, Greenbelt, Maryland 20771 (United States); Jahn, Jörg-Micha [Southwest Research Institute, 6220 Culebra Road, San Antonio, Texas 78238 (United States); University of Texas at San Antonio, One UTSA circle, San Antonio, Texas 78249 (United States)

    2016-05-15

    The design, development, and performance of Medium-energy Electron SPectrometer (MESP), dedicated to the in situ observation of suprathermal electrons in the auroral ionosphere, are summarized in this paper. MESP employs a permanent magnet filter with a light tight structure to select electrons with proper energies guided to the detectors. A combination of two avalanche photodiodes and a large area solid-state detector (SSD) provided 46 total energy bins (1 keV resolution for 3−20 keV range for APDs, and 7 keV resolution for >20 keV range for SSDs). Multi-channel ultra-low power application-specific integrated circuits are also verified for the flight operation to read-out and analyze the detector signals. MESP was launched from Poker Flat Research Range on 3 March 2014 as a part of ground-to-rocket electrodynamics-electrons correlative experiment (GREECE) mission. MESP successfully measured the precipitating electrons from 3 to 120 keV in 120-ms time resolution and characterized the features of suprathermal distributions associated with auroral arcs throughout the flight. The measured electrons were showing the inverted-V type spectra, consistent with the past measurements. In addition, investigations of the suprathermal electron population indicated the existence of the energetic non-thermal distribution corresponding to the brightest aurora.

  19. Development and performance of a suprathermal electron spectrometer to study auroral precipitations

    International Nuclear Information System (INIS)

    Ogasawara, Keiichi; Stange, Jason L.; Trevino, John A.; Webster, James; Grubbs, Guy; Michell, Robert G.; Samara, Marilia; Jahn, Jörg-Micha

    2016-01-01

    The design, development, and performance of Medium-energy Electron SPectrometer (MESP), dedicated to the in situ observation of suprathermal electrons in the auroral ionosphere, are summarized in this paper. MESP employs a permanent magnet filter with a light tight structure to select electrons with proper energies guided to the detectors. A combination of two avalanche photodiodes and a large area solid-state detector (SSD) provided 46 total energy bins (1 keV resolution for 3−20 keV range for APDs, and 7 keV resolution for >20 keV range for SSDs). Multi-channel ultra-low power application-specific integrated circuits are also verified for the flight operation to read-out and analyze the detector signals. MESP was launched from Poker Flat Research Range on 3 March 2014 as a part of ground-to-rocket electrodynamics-electrons correlative experiment (GREECE) mission. MESP successfully measured the precipitating electrons from 3 to 120 keV in 120-ms time resolution and characterized the features of suprathermal distributions associated with auroral arcs throughout the flight. The measured electrons were showing the inverted-V type spectra, consistent with the past measurements. In addition, investigations of the suprathermal electron population indicated the existence of the energetic non-thermal distribution corresponding to the brightest aurora.

  20. Supra-thermal charged particle energies in a low pressure radio-frequency electrical discharge in air

    International Nuclear Information System (INIS)

    Littlefield, R.G.

    1976-01-01

    Velocity spectra of supra-thermal electrons escaping from a low-pressure radio-frequency discharge in air have been measured by a time-of-flight method of original design. In addition, the energy spectra of the supra-thermal electrons and positive ions escaping from the rf discharge have been measured by a retarding potential method. Various parameters affecting the energy of the supra-thermal charged particles are experimentally investigated. A model accounting for the supra-thermal charged particle energies is developed and is shown to be consistent with experimental observations

  1. Suppression of suprathermal ions from a colloidal microjet target containing SnO2 nanoparticles by using double laser pulses

    International Nuclear Information System (INIS)

    Higashiguchi, Takeshi; Kaku, Masanori; Katto, Masahito; Kubodera, Shoichi

    2007-01-01

    We have demonstrated suppression of suprathermal ions from a colloidal microjet target plasma containing tin-dioxide (SnO 2 ) nanoparticles irradiated by double laser pulses. We observed a significant decrease of the tin and oxygen ion signals in the charged-state-separated energy spectra when double laser pulses were irradiated. The peak energy of the singly ionized tin ions decreased from 9 to 3 keV when a preplasma was produced. The decrease in the ion energy, considered as debris suppression, is attributed to the interaction between an expanding low-density preplasma and a main laser pulse

  2. Suppression of suprathermal ions from a colloidal microjet target containing SnO2 nanoparticles by using double laser pulses

    Science.gov (United States)

    Higashiguchi, Takeshi; Kaku, Masanori; Katto, Masahito; Kubodera, Shoichi

    2007-10-01

    We have demonstrated suppression of suprathermal ions from a colloidal microjet target plasma containing tin-dioxide (SnO2) nanoparticles irradiated by double laser pulses. We observed a significant decrease of the tin and oxygen ion signals in the charged-state-separated energy spectra when double laser pulses were irradiated. The peak energy of the singly ionized tin ions decreased from 9to3keV when a preplasma was produced. The decrease in the ion energy, considered as debris suppression, is attributed to the interaction between an expanding low-density preplasma and a main laser pulse.

  3. New Measurements of Suprathermal Ions, Energetic Particles, and Cosmic Rays in the Outer Heliosphere from the New Horizons PEPSSI Instrument

    Science.gov (United States)

    Hill, M. E.; Kollmann, P.; McNutt, R. L., Jr.; Stern, A.; Weaver, H. A., Jr.; Young, L. A.; Olkin, C.; Spencer, J. R.

    2017-12-01

    During the period from January 2012 to December 2017 the New Horizons spacecraft traveled from 22 to 41 AU from the Sun, making nearly continuous interplanetary plasma and particle measurements utilizing the SWAP and PEPSSI instruments. We report on newly extended measurements from PEPSSI (Pluto Energetic Particle Spectrometer Science Investigation) that now bring together suprathermal particles above 2 keV/nuc (including interstellar pickup ions), energetic particles with H, He, and O composition from 30 keV to 1 MeV, and cosmic rays above 65 MeV (with effective count-rate-limited upper energy of 1 GeV). Such a wide energy range allows us to look at the solar wind structures passing over the spacecraft, the energetic particles that are often accelerated by these structures, and the suppression of cosmic rays resulting from the increased turbulence inhibiting cosmic ray transport to the spacecraft position (i.e., Forbush decreases). This broad perspective provides simultaneous, previously unattainable diagnostics of outer heliospheric particle dynamics and acceleration. Besides the benefit of being recent, in-ecliptic measurements, unlike the historic Voyager 1 and 2 spacecraft, these PEPSSI observations are also totally unique in the suprathermal range; in this region only PEPSSI can span the suprathermal range, detecting a population that is a linchpin to understanding the outer heliosphere.

  4. Heating and generation of suprathermal particles at collisionless shocks

    International Nuclear Information System (INIS)

    Thomsen, M.F.

    1985-01-01

    Collisionless plasma shocks are different from ordinary collisional fluid shocks in several important respects. They do not in general heat the electrons and ions equally, nor do they produce Maxwellian velocity distributions downstream. Furthermore, they commonly generate suprathermal particles which propagate into the upstream region, giving advance warning of the presence of the shock and providing a ''seed'' population for further acceleration to high energies. Recent space observations and theory have revealed a great deal about the heating mechanisms which occur in collisionless shocks and about the origin of the various suprathermal particle populations which are found in association with them. An overview of the present understanding of these subjects is presented herein. 83 refs., 8 figs

  5. Suprathermal ions in the solar wind from the Voyager spacecraft: Instrument modeling and background analysis

    International Nuclear Information System (INIS)

    Randol, B M; Christian, E R

    2015-01-01

    Using publicly available data from the Voyager Low Energy Charged Particle (LECP) instruments, we investigate the form of the solar wind ion suprathermal tail in the outer heliosphere inside the termination shock. This tail has a commonly observed form in the inner heliosphere, that is, a power law with a particular spectral index. The Voyager spacecraft have taken data beyond 100 AU, farther than any other spacecraft. However, during extended periods of time, the data appears to be mostly background. We have developed a technique to self-consistently estimate the background seen by LECP due to cosmic rays using data from the Voyager cosmic ray instruments and a simple, semi-analytical model of the LECP instruments

  6. Spatial variations in the suprathermal ion distributions during substorms in the plasma sheet

    International Nuclear Information System (INIS)

    Kistler, L.M.; Moebius, E.; Klecker, B.; Gloeckler, G.; Ipavich, F.M.; Hamilton, D.C.

    1990-01-01

    Using data from AMPTE IRM and AMPTE CCE, the authors have determined the pre- and post-injection suprathermal energy spectra for the ion species H + , O + , He + , and He ++ for six events in which substorm-associated particle injections are observed in both the near-Earth plasma sheet and farther down the tail. They find similar spectral changes in both locations, with the spectra becoming harder with the injection. Post-injection, the flux decreases exponentially with radial distance. Approximately the same gradient is observed in all species. In addition, they find that although the O + /H + and the He ++ /H + ratios increase with energy per charge, the ratios are approximately the same at the same energy per charge at the two spacecraft. The observations are difficult to explain either with a model in which the ions are accelerated at a neutral line and transported toward Earth or with a model in which the ions are accelerated in the near-Earth region by current disruption/diversion and transported down the tail. In either case, the ions would have to be transported throughout the tail without much energization or deenergization in order to explain the energy per charge correlations. Further, earthward transport without energization would not lead to the observed radial gradient. A combination of these acceleration mechanisms, a disturbance that propagates throughout the plasma sheet, or a more global mechanism may explain the observations

  7. Time Variations of the Spectral Indices of the Suprathermal Distribution as observed by WIND/STICS

    Science.gov (United States)

    Gruesbeck, J. R.; Christian, E. R.; Lepri, S. T.; Thomas, J.; Zurbuchen, T.; Gloeckler, G.

    2011-12-01

    Suprathermal particle spectra, measured in various regions of the heliosphere and heliosheath by Ulysses, ACE and Voyager, have recently been reported. In many cases long accumulation times had to be used to obtain sufficient statistical accuracy, and corrections were necessary, since only a fraction of phase space was measured. The SupraThermal Ion Composition Spectrometer (STICS), onboard Wind, enables observations of the suprathermal plasma in the solar wind at much higher time resolution. In addition, the STICS samples nearly full three-dimensional phase space, enabling measurements of anisotropies. We present a multi-year investigation of the spectral index of the suprathermal distribution, accumulated over 1 day and less, where we see significant time variation. An average lower bound value of the spectral index is at ~ -5, however, there are time periods during which the observed distributions steepen. We will also present an analysis of time and spatial variations of the suprathermal particle fluxes, observed by STICS and other instruments. In particular, we will compare the observed variability with predictions from a model by Bochsler and Moebius, based on data of the Interstellar Boundary Explorer (IBEX), who postulated that energetic neutral atoms, from outside of the heliosheath, which then penetrate the inner heliosphere and are finally ionized, could be a source of the very suprathermal populations we observe.

  8. Suprathermal viscosity of dense matter

    International Nuclear Information System (INIS)

    Alford, Mark; Mahmoodifar, Simin; Schwenzer, Kai

    2010-01-01

    Motivated by the existence of unstable modes of compact stars that eventually grow large, we study the bulk viscosity of dense matter, taking into account non-linear effects arising in the large amplitude regime, where the deviation μ Δ of the chemical potentials from chemical equilibrium fulfills μ Δ > or approx. T. We find that this supra-thermal bulk viscosity can provide a potential mechanism for saturating unstable modes in compact stars since the viscosity is strongly enhanced. Our study confirms previous results on strange quark matter and shows that the suprathermal enhancement is even stronger in the case of hadronic matter. We also comment on the competition of different weak channels and the presence of suprathermal effects in various color superconducting phases of dense quark matter.

  9. Electron cyclotron heating and supra-thermal electron dynamics in the TCV Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Gnesin, S.

    2011-10-15

    This thesis is concerned with the physics of supra-thermal electrons in thermonuclear, magnetically confined plasmas. Under a variety of conditions, in laboratory as well as space plasmas, the electron velocity distribution function is not in thermodynamic equilibrium owing to internal or external drives. Accordingly, the distribution function departs from the equilibrium Maxwellian, and in particular generally develops a high-energy tail. In tokamak plasmas, this occurs especially as a result of injection of high-power electromagnetic waves, used for heating and current drive, as well as a result of internal magnetohydrodynamic (MHD) instabilities. The physics of these phenomena is intimately tied to the properties and dynamics of this supra-thermal electron population. This motivates the development of instrumental apparatus to measure its properties as well as of numerical codes to simulate their dynamics. Both aspects are reflected in this thesis work, which features advanced instrumental development and experimental measurements as well as numerical modeling. The instrumental development consisted of the complete design of a spectroscopic and tomographic system of four multi-detector hard X-ray (HXR) cameras for the TCV tokamak. The goal is to measure bremsstrahlung emission from supra-thermal electrons with energies in the 10-300 keV range, with the ultimate aim of providing the first full tomographic reconstruction at these energies in a noncircular plasma. In particular, supra-thermal electrons are generated in TCV by a high-power electron cyclotron heating (ECH) system and are also observed in the presence of MHD events, such as sawtooth oscillations and disruptive instabilities. This diagnostic employs state-of-the-art solid-state detectors and is optimized for the tight space requirements of the TCV ports. It features a novel collimator concept that combines compactness and flexibility as well as full digital acquisition of the photon pulses, greatly

  10. Electron cyclotron heating and supra-thermal electron dynamics in the TCV Tokamak

    International Nuclear Information System (INIS)

    Gnesin, S.

    2011-10-01

    This thesis is concerned with the physics of supra-thermal electrons in thermonuclear, magnetically confined plasmas. Under a variety of conditions, in laboratory as well as space plasmas, the electron velocity distribution function is not in thermodynamic equilibrium owing to internal or external drives. Accordingly, the distribution function departs from the equilibrium Maxwellian, and in particular generally develops a high-energy tail. In tokamak plasmas, this occurs especially as a result of injection of high-power electromagnetic waves, used for heating and current drive, as well as a result of internal magnetohydrodynamic (MHD) instabilities. The physics of these phenomena is intimately tied to the properties and dynamics of this supra-thermal electron population. This motivates the development of instrumental apparatus to measure its properties as well as of numerical codes to simulate their dynamics. Both aspects are reflected in this thesis work, which features advanced instrumental development and experimental measurements as well as numerical modeling. The instrumental development consisted of the complete design of a spectroscopic and tomographic system of four multi-detector hard X-ray (HXR) cameras for the TCV tokamak. The goal is to measure bremsstrahlung emission from supra-thermal electrons with energies in the 10-300 keV range, with the ultimate aim of providing the first full tomographic reconstruction at these energies in a noncircular plasma. In particular, supra-thermal electrons are generated in TCV by a high-power electron cyclotron heating (ECH) system and are also observed in the presence of MHD events, such as sawtooth oscillations and disruptive instabilities. This diagnostic employs state-of-the-art solid-state detectors and is optimized for the tight space requirements of the TCV ports. It features a novel collimator concept that combines compactness and flexibility as well as full digital acquisition of the photon pulses, greatly

  11. Source Population and Acceleration Location of Suprathermal Heavy Ions in Corotating Interaction Regions

    Energy Technology Data Exchange (ETDEWEB)

    Filwett, R. J.; Desai, M. I. [University of Texas at San Antonio, San Antonio, TX (United States); Dayeh, M. A.; Broiles, T. W. [Southwest Research Institute, San Antonio, TX (United States)

    2017-03-20

    We have analyzed the ∼20–320 keV nucleon{sup −1} suprathermal (ST) heavy ion abundances in 41 corotating interaction regions (CIRs) observed by the Wind spacecraft from 1995 January to 2008 December. Our results are: (1) the CIR Fe/CNO and NeS/CNO ratios vary with the sunspot number, with values being closer to average solar energetic particle event values during solar maxima and lower than nominal solar wind values during solar minima. The physical mechanism responsible for the depleted abundances during solar minimum remains an open question. (2) The Fe/CNO increases with energy in the 6 events that occurred during solar maximum, while no such trends are observed for the 35 events during solar minimum. (3) The Fe/CNO shows no correlation with the average solar wind speed. (4) The Fe/CNO is well correlated with the corresponding upstream ∼20–320 keV nucleon{sup −1} Fe/CNO and not with the solar wind Fe/O measured by ACE in 31 events. Using the correlations between the upstream ∼20–40 keV nucleon{sup −1} Fe/CNO and the ∼20–320 keV nucleon{sup −1} Fe/CNO in CIRs, we estimate that, on average, the ST particles traveled ∼2 au along the nominal Parker spiral field line, which corresponds to upper limits for the radial distance of the source or acceleration location of ∼1 au beyond Earth orbit. Our results are consistent with those obtained from recent surveys, and confirm that CIR ST heavy ions are accelerated more locally, and are at odds with the traditional viewpoint that CIR ions seen at 1 au are bulk solar wind ions accelerated between 3 and 5 au.

  12. SUPRATHERMAL ELECTRONS AT SATURN'S BOW SHOCK

    International Nuclear Information System (INIS)

    Masters, A.; Dougherty, M. K.; Sulaiman, A. H.; Sergis, N.; Stawarz, L.; Fujimoto, M.; Coates, A. J.

    2016-01-01

    The leading explanation for the origin of galactic cosmic rays is particle acceleration at the shocks surrounding young supernova remnants (SNRs), although crucial aspects of the acceleration process are unclear. The similar collisionless plasma shocks frequently encountered by spacecraft in the solar wind are generally far weaker (lower Mach number) than these SNR shocks. However, the Cassini spacecraft has shown that the shock standing in the solar wind sunward of Saturn (Saturn's bow shock) can occasionally reach this high-Mach number astrophysical regime. In this regime Cassini has provided the first in situ evidence for electron acceleration under quasi-parallel upstream magnetic conditions. Here we present the full picture of suprathermal electrons at Saturn's bow shock revealed by Cassini . The downstream thermal electron distribution is resolved in all data taken by the low-energy electron detector (CAPS-ELS, <28 keV) during shock crossings, but the higher energy channels were at (or close to) background. The high-energy electron detector (MIMI-LEMMS, >18 keV) measured a suprathermal electron signature at 31 of 508 crossings, where typically only the lowest energy channels (<100 keV) were above background. We show that these results are consistent with the theory in which the “injection” of thermal electrons into an acceleration process involves interaction with whistler waves at the shock front, and becomes possible for all upstream magnetic field orientations at high Mach numbers like those of the strong shocks around young SNRs. A future dedicated study will analyze the rare crossings with evidence for relativistic electrons (up to ∼1 MeV).

  13. SUPRATHERMAL ELECTRONS AT SATURN'S BOW SHOCK

    Energy Technology Data Exchange (ETDEWEB)

    Masters, A.; Dougherty, M. K. [The Blackett Laboratory, Imperial College London, Prince Consort Road, London, SW7 2AZ (United Kingdom); Sulaiman, A. H. [Department of Physics and Astronomy, University of Iowa, Iowa City, IA 52242 (United States); Sergis, N. [Office of Space Research and Technology, Academy of Athens, Soranou Efesiou 4, 11527 Athens (Greece); Stawarz, L. [Astronomical Observatory, Jagiellonian University, ul. Orla 171, 30-244 Krakow (Poland); Fujimoto, M. [Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency, 3-1-1 Yoshinodai, Chuo-ku, Sagamihara, Kanagawa 252-5210 (Japan); Coates, A. J., E-mail: a.masters@imperial.ac.uk [Mullard Space Science Laboratory, Department of Space and Climate Physics, University College London, Holmbury St. Mary, Dorking RH5 6NT (United Kingdom)

    2016-07-20

    The leading explanation for the origin of galactic cosmic rays is particle acceleration at the shocks surrounding young supernova remnants (SNRs), although crucial aspects of the acceleration process are unclear. The similar collisionless plasma shocks frequently encountered by spacecraft in the solar wind are generally far weaker (lower Mach number) than these SNR shocks. However, the Cassini spacecraft has shown that the shock standing in the solar wind sunward of Saturn (Saturn's bow shock) can occasionally reach this high-Mach number astrophysical regime. In this regime Cassini has provided the first in situ evidence for electron acceleration under quasi-parallel upstream magnetic conditions. Here we present the full picture of suprathermal electrons at Saturn's bow shock revealed by Cassini . The downstream thermal electron distribution is resolved in all data taken by the low-energy electron detector (CAPS-ELS, <28 keV) during shock crossings, but the higher energy channels were at (or close to) background. The high-energy electron detector (MIMI-LEMMS, >18 keV) measured a suprathermal electron signature at 31 of 508 crossings, where typically only the lowest energy channels (<100 keV) were above background. We show that these results are consistent with the theory in which the “injection” of thermal electrons into an acceleration process involves interaction with whistler waves at the shock front, and becomes possible for all upstream magnetic field orientations at high Mach numbers like those of the strong shocks around young SNRs. A future dedicated study will analyze the rare crossings with evidence for relativistic electrons (up to ∼1 MeV).

  14. Stereo ENA Imaging of the Ring Current and Multi-point Measurements of Suprathermal Particles and Magnetic Fields by TRIO-CINEMA

    Science.gov (United States)

    Lin, R. P.; Sample, J. G.; Immel, T. J.; Lee, D.; Horbury, T. S.; Jin, H.; SEON, J.; Wang, L.; Roelof, E. C.; Lee, E.; Parks, G. K.; Vo, H.

    2012-12-01

    The TRIO (Triplet Ionospheric Observatory) - CINEMA (Cubesat for Ions, Neutrals, Electrons, & Magnetic fields) mission consists of three identical 3-u cubesats to provide high sensitivity, high cadence, stereo measurements of Energetic Neutral Atoms (ENAs) from the Earth's ring current with ~1 keV FWHM energy resolution from ~4 to ~200 keV, as well as multi-point in situ measurements of magnetic fields and suprathermal electrons (~2 -200 keV) and ions (~ 4 -200 keV) in the auroral and ring current precipitation regions in low Earth orbit (LEO). A new Suprathermal Electron, Ion, Neutral (STEIN) instrument, using a 32-pixel silicon semiconductor detector with an electrostatic deflection system to separate ENAs from ions and from electrons below 30 keV, will sweep over most of the sky every 15 s as the spacecraft spins at 4 rpm. In addition, inboard and outboard (on an extendable 1m boom) miniature magnetoresistive sensor magnetometers will provide high cadence 3-axis magnetic field measurements. An S-band transmitter will be used to provide ~8 kbps orbit-average data downlink to the ~11m diameter antenna of the Berkeley Ground Station.The first CINEMA (funded by NSF) is scheduled for launch on August 14, 2012 into a 65 deg. inclination LEO. Two more identical CINEMAs are being developed by Kyung Hee University (KHU) in Korea under the World Class University (WCU) program, for launch in November 2012 into a Sun-synchronous LEO to form TRIO-CINEMA. A fourth CINEMA is being developed for a 2013 launch into LEO. This LEO constellation of nanosatellites will provide unique measurements highly complementary to NASA's RBSP and THEMIS missions. Furthermore, CINEMA's development of miniature particle and magnetic field sensors, and cubesat-size spinning spacecraft may be important for future constellation space missions. Initial results from the first CINEMA will be presented if available.

  15. Measurement of suprathermal electron confinement by cyclotron transmission

    International Nuclear Information System (INIS)

    Kirkwood, R.; Hutchinson, I.H.; Luckhardt, S.C.; Porkolab, M.; Squire, J.P.

    1990-01-01

    The confinement time of suprathermal electrons is determined experimentally from the distribution function determined via wave transmission measurements. Measurements of the lowest moment of the distribution perpendicular to the B field as a function of the parallel electron momentum as well as the global input power allow the suprathermal electron confinement time (τ se ) to be calculated during lower-hybrid and inductive current drive. Finite particle confinement is found to be the dominant energy loss term for the suprathermals and improves with plasma current and density

  16. ITER Plasma at Electron Cyclotron Frequency Domain: Stimulated Raman Scattering off Gould-Trivelpiece Modes and Generation of Suprathermal Electrons and Energetic Ions

    Science.gov (United States)

    Stefan, V. Alexander

    2011-04-01

    Stimulated Raman scattering in the electron cyclotron frequency range of the X-Mode and O-Mode driver with the ITER plasma leads to the ``tail heating'' via the generation of suprathermal electrons and energetic ions. The scattering off Trivelpiece-Gould (T-G) modes is studied for the gyrotron frequency of 170GHz; X-Mode and O-Mode power of 24 MW CW; on-axis B-field of 10T. The synergy between the two-plasmon decay and Raman scattering is analyzed in reference to the bulk plasma heating. Supported in part by Nikola TESLA Labs, La Jolla, CA

  17. Suprathermal grains: on intergalactic magnetic fields

    International Nuclear Information System (INIS)

    Dasgupta, A.K.

    1979-01-01

    Charged dust grains of radii a approximately equal to 3 x 10 -6 to approximately 3 x 10 -5 cm may be driven out of the galaxy due to radiation pressure of starlight. Once clear of the main gas-dust layer, dust grains may then escape into intergalactic space. Such grains are virtually indestructible-being evaporated only during formation. The dust grains, once injected into the intergalactic medium, may acquire suprathermal energy, thus 'suprathermal grains' in collision with magnetized cloud by the Fermi process. In order to attain relativistic energy, suprathermal grains have to move in and out ('scattering') of the magnetic field of the medium. It is now well established that high energy cosmic rays are of the order 10 20 eV or more. It has been speculated that these high energy (> = 10 18 eV) cosmic ray particles are charged dust grains, of intergalactic origin. This is possible only if there exists a magnetic field in the intergalactic medium. (Auth.)

  18. SUPRATHERMAL ELECTRONS IN THE SOLAR CORONA: CAN NONLOCAL TRANSPORT EXPLAIN HELIOSPHERIC CHARGE STATES?

    International Nuclear Information System (INIS)

    Cranmer, Steven R.

    2014-01-01

    There have been several ideas proposed to explain how the Sun's corona is heated and how the solar wind is accelerated. Some models assume that open magnetic field lines are heated by Alfvén waves driven by photospheric motions and dissipated after undergoing a turbulent cascade. Other models posit that much of the solar wind's mass and energy is injected via magnetic reconnection from closed coronal loops. The latter idea is motivated by observations of reconnecting jets and also by similarities of ion composition between closed loops and the slow wind. Wave/turbulence models have also succeeded in reproducing observed trends in ion composition signatures versus wind speed. However, the absolute values of the charge-state ratios predicted by those models tended to be too low in comparison with observations. This Letter refines these predictions by taking better account of weak Coulomb collisions for coronal electrons, whose thermodynamic properties determine the ion charge states in the low corona. A perturbative description of nonlocal electron transport is applied to an existing set of wave/turbulence models. The resulting electron velocity distributions in the low corona exhibit mild suprathermal tails characterized by ''kappa'' exponents between 10 and 25. These suprathermal electrons are found to be sufficiently energetic to enhance the charge states of oxygen ions, while maintaining the same relative trend with wind speed that was found when the distribution was assumed to be Maxwellian. The updated wave/turbulence models are in excellent agreement with solar wind ion composition measurements

  19. ON THE REMOTE DETECTION OF SUPRATHERMAL IONS IN THE SOLAR CORONA AND THEIR ROLE AS SEEDS FOR SOLAR ENERGETIC PARTICLE PRODUCTION

    Energy Technology Data Exchange (ETDEWEB)

    Laming, J. Martin; Moses, J. Daniel; Ko, Yuan-Kuen [Space Science Division, Naval Research Laboratory, Code 7684, Washington, DC 20375 (United States); Ng, Chee K. [College of Science, George Mason University, Fairfax, VA 22030 (United States); Rakowski, Cara E.; Tylka, Allan J. [NASA/GSFC Code 672, Greenbelt, MD 20771 (United States)

    2013-06-10

    Forecasting large solar energetic particle (SEP) events associated with shocks driven by fast coronal mass ejections (CMEs) poses a major difficulty in the field of space weather. Besides issues associated with CME initiation, the SEP intensities are difficult to predict, spanning three orders of magnitude at any given CME speed. Many lines of indirect evidence point to the pre-existence of suprathermal seed particles for injection into the acceleration process as a key ingredient limiting the SEP intensity of a given event. This paper outlines the observational and theoretical basis for the inference that a suprathermal particle population is present prior to large SEP events, explores various scenarios for generating seed particles and their observational signatures, and explains how such suprathermals could be detected through measuring the wings of the H I Ly{alpha} line.

  20. ON THE REMOTE DETECTION OF SUPRATHERMAL IONS IN THE SOLAR CORONA AND THEIR ROLE AS SEEDS FOR SOLAR ENERGETIC PARTICLE PRODUCTION

    International Nuclear Information System (INIS)

    Laming, J. Martin; Moses, J. Daniel; Ko, Yuan-Kuen; Ng, Chee K.; Rakowski, Cara E.; Tylka, Allan J.

    2013-01-01

    Forecasting large solar energetic particle (SEP) events associated with shocks driven by fast coronal mass ejections (CMEs) poses a major difficulty in the field of space weather. Besides issues associated with CME initiation, the SEP intensities are difficult to predict, spanning three orders of magnitude at any given CME speed. Many lines of indirect evidence point to the pre-existence of suprathermal seed particles for injection into the acceleration process as a key ingredient limiting the SEP intensity of a given event. This paper outlines the observational and theoretical basis for the inference that a suprathermal particle population is present prior to large SEP events, explores various scenarios for generating seed particles and their observational signatures, and explains how such suprathermals could be detected through measuring the wings of the H I Lyα line.

  1. Calorimetric low temperature detectors for heavy ion physics

    Energy Technology Data Exchange (ETDEWEB)

    Egelhof, P.; Kraft-Bermuth, S. [Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (Germany)]|[Mainz Univ. (Germany). Inst. fuer Physik

    2005-05-01

    Calorimetric low temperature detectors have the potential to become powerful tools for applications in many fields of heavy ion physics. A brief overview of heavy ion physics at present and at the next generation heavy ion facilities is given with a special emphasis on the conditions for heavy ion detection and the potential advantage of cryogenic detectors for applications in heavy ion physics. Two types of calorimetric low temperature detectors for the detection of energetic heavy ions have been developed and their response to the impact of heavy ions was investigated systematically for a wide range of energies (E=0.1-360 MeV/amu) and ion species ({sup 4}He.. {sup 238}U). Excellent results with respect to energy resolution, {delta}E/E ranging from 1 to 5 x 10{sup -3} even for the heaviest ions, and other basic detector properties such as energy linearity with no indication of a pulse height defect, energy threshold, detection efficiency and radiation hardness have been obtained, representing a considerable improvement as compared to conventional heavy ion detectors based on ionization. With the achieved performance, calorimetric low temperature detectors bear a large potential for applications in various fields of basic and applied heavy ion research. A brief overview of a few prominent examples, such as high resolution nuclear spectroscopy, high resolution nuclear mass determination, which may be favourably used for identification of superheavy elements or in direct reaction experiments with radioactive beams, as well as background discrimination in accelerator mass spectrometry, is given, and first results are presented. For instance, the use of cryogenic detectors allowed to improve the sensitivity in trace analysis of {sup 236}U by one order of magnitude and to determine the up to date smallest isotope ratio of {sup 236}U/{sup 238}U = 6.1 x 10{sup -12} in a sample of natural uranium. Besides the detection of heavy ions, the concept of cryogenic detectors also

  2. Calorimetric low temperature detectors for heavy ion physics

    International Nuclear Information System (INIS)

    Egelhof, P.; Kraft-Bermuth, S.; Mainz Univ.

    2005-07-01

    Calorimetric low temperature detectors have the potential to become powerful tools for applications in many fields of heavy ion physics. A brief overview of heavy ion physics at present and at the next generation heavy ion facilities is given with a special emphasis on the conditions for heavy ion detection and the potential advantage of cryogenic detectors for applications in heavy ion physics. Two types of calorimetric low temperature detectors for the detection of energetic heavy ions have been developed and their response to the impact of heavy ions was investigated systematically for a wide range of energies (E=0.1-360 MeV/amu) and ion species ( 4 He.. 238 U). Excellent results with respect to energy resolution, ΔE/E ranging from 1 to 5 x 10 -3 even for the heaviest ions, and other basic detector properties such as energy linearity with no indication of a pulse height defect, energy threshold, detection efficiency and radiation hardness have been obtained, representing a considerable improvement as compared to conventional heavy ion detectors based on ionization. With the achieved performance, calorimetric low temperature detectors bear a large potential for applications in various fields of basic and applied heavy ion research. A brief overview of a few prominent examples, such as high resolution nuclear spectroscopy, high resolution nuclear mass determination, which may be favourably used for identification of superheavy elements or in direct reaction experiments with radioactive beams, as well as background discrimination in accelerator mass spectrometry, is given, and first results are presented. For instance, the use of cryogenic detectors allowed to improve the sensitivity in trace analysis of 236 U by one order of magnitude and to determine the up to date smallest isotope ratio of 236 U/ 238 U = 6.1 x 10 -12 in a sample of natural uranium. Besides the detection of heavy ions, the concept of cryogenic detectors also provides considerable advantage for X

  3. Electron beam-plasma interaction and electron-acoustic solitary waves in a plasma with suprathermal electrons

    Science.gov (United States)

    Danehkar, A.

    2018-06-01

    Suprathermal electrons and inertial drifting electrons, so called electron beam, are crucial to the nonlinear dynamics of electrostatic solitary waves observed in several astrophysical plasmas. In this paper, the propagation of electron-acoustic solitary waves (EAWs) is investigated in a collisionless, unmagnetized plasma consisting of cool inertial background electrons, hot suprathermal electrons (modeled by a κ-type distribution), and stationary ions. The plasma is penetrated by a cool electron beam component. A linear dispersion relation is derived to describe small-amplitude wave structures that shows a weak dependence of the phase speed on the electron beam velocity and density. A (Sagdeev-type) pseudopotential approach is employed to obtain the existence domain of large-amplitude solitary waves, and investigate how their nonlinear structures depend on the kinematic and physical properties of the electron beam and the suprathermality (described by κ) of the hot electrons. The results indicate that the electron beam can largely alter the EAWs, but can only produce negative polarity solitary waves in this model. While the electron beam co-propagates with the solitary waves, the soliton existence domain (Mach number range) becomes narrower (nearly down to nil) with increasing the beam speed and the beam-to-hot electron temperature ratio, and decreasing the beam-to-cool electron density ratio in high suprathermality (low κ). It is found that the electric potential amplitude largely declines with increasing the beam speed and the beam-to-cool electron density ratio for co-propagating solitary waves, but is slightly decreased by raising the beam-to-hot electron temperature ratio.

  4. Heavy ion collisions with the ATLAS detector

    International Nuclear Information System (INIS)

    Nevski, Pavel

    2004-01-01

    The ATLAS detector is designed to study high-p T physics in proton-proton collisions at the LHC design luminosity. The detector capabilities for heavy-ion physics are now being evaluated. This paper reports on a preliminary assessment of the baseline ATLAS detector potential for heavy-ion physics. The ATLAS sensitivity to some of the expected signatures from the quark-gluon plasma (e.g. jet quenching, Υ suppression) is discussed. (orig.)

  5. 5-D simulation study of suprathermal electron transport in non-axisymmetric plasmas

    International Nuclear Information System (INIS)

    Murakami, S.; Idei, H.; Kubo, S.; Nakajima, N.; Okamoto, M.; Gasparino, U.; Maassberg, H.; Rome, M.; Marushchenko, N.

    2000-01-01

    ECRH driven transport of suprathermal electrons is studied in non-axisymmetric plasmas using a new Monte Carlo simulation technique in 5-D phase space. Two different phases of the ECRH driven transport of suprathermal electrons can be seen. The first is a rapid convective phase due to the direct radial motion of trapped electrons and the second is a slower phase due to the collisional transport. The important role of the radial transport of suprathermal electrons in the broadening of the ECRH deposition profile in W7-AS is clarified. The ECRH driven flux is also evaluated and considered in relation to the 'electron root' feature recently observed in W7-AS. It is found that, at low collisionalities, the ECRH driven flux due to the suprathermal electrons can play a dominant role in the condition of ambipolarity, and thus the observed electron root feature in W7-AS is thought to be driven by the radial (convective) flux of ECRH generated suprathermal electrons. A possible scenario for this type of electron root is considered for the LHD plasma. (author)

  6. 5D simulation study of suprathermal electron transport in non-axisymmetric plasmas

    International Nuclear Information System (INIS)

    Murakami, S.; Idei, H.; Kubo, S.; Nakajima, N.; Okamoto, M.; Gasparino, U.; Maassberg, H.; Rome, M.; Marushchenko, N.

    1999-01-01

    ECRH-driven transport of suprathermal electrons is studied in non-axisymmetric plasmas using a new Monte Carlo simulation technique in 5D phase space. Two different phases of the ECRH-driven transport of suprathermal electrons can be seen; one is a rapid convective phase due to the direct radial motion of trapped electrons and the other is a slower phase due to the collisional transport. The important role of the radial transport of suprathermal electrons in the broadening of the ECRH deposition profile is clarified in W7-AS. The ECRH driven flux is also evaluated and put in relation with the 'electron root' feature recently observed in W7-AS. It is found that, at low collisionalities, the ECRH driven flux due to the suprathermal electrons can play a dominant role in the condition of ambipolarity and, thus, the observed 'electron root' feature in W7-AS is thought to be driven by the radial (convective) flux of ECRH generated suprathermal electrons. The possible scenario of this 'ECRH-driven electron root' is considered in the LHD plasma. (author)

  7. Data acquisition for the HILI [Heavy Ion Light Ion] detector

    International Nuclear Information System (INIS)

    Teh, K.M.; Shapira, D.; McConnell, J.W.; Kim, H.; Novotny, R.

    1987-01-01

    A large acceptance, multi-segmented detector system capable of the simultaneous detection of heavy and light ions has been constructed. The heavy ions are detected with a segmented gas ionization chamber and a multiwire proportional counter while the light ions are detected with a 192 element plastic phoswich hodoscope. Processing the large number of signals is accomplished through a combination of CAMAC and FASTBUS modules and preprocessors, and a Host minicomputer. Details of the data acquisition system and the reasons for adopting a dual standards system are discussed. In addition, a technique for processing signals from an individual hodoscope detector is presented. 4 refs., 3 figs

  8. Heavy ion measurement by chemical detectors

    International Nuclear Information System (INIS)

    Huebner, K.; Erzgraeber, G.; Eichhorn, K.

    1979-02-01

    In testing the applicability of the threshold system polyvinyl alcohol/methyl orange/chloral hydrate/sodium tetraborate to the quantitative detection of single particles, the chemical detector was irradiated with 4 He, 12 C, 18 O, 22 He ions of different LET. Detectors with 4 different borax concentrations (chloral hydrate concentration kept constant) have been irradiated. The dose causing the colour change increased linearly with the borax concentration. For equal borax concentrations this dose increases with increasing LET due to the decreasing G value of the HCl. The fluence ranges measurable with the various detector compositions are given. 4 He and 18 O ion ranges have been determined. The measured depth dose curves have been corrected because the dose is LET-dependent. The experimentally determined ranges are in good agreement with values calculated for the detector material

  9. Ion detectors for isotopic measurements

    Energy Technology Data Exchange (ETDEWEB)

    McCormick, A.

    1978-12-15

    Detector development over the past two decades has been such that this is now the least likely part of the mass spectrometry equipment to give rise to the sort of measurement errors to cause concern. It is now possible to choose from a number of different types of device which can provide more or less 100% efficiency in ion beam detection under all conceivable experimental conditions required for isotopic analysis, from measurement of large samples using the traditional Faraday cage to measurement of exceedingly small ion currents by ion counting techniques. There are even methods of distinguishing one type of ionic species from another in the detector, thus improving the accuracy when unwanted isobaric species might otherwise grossly distort the measurement. Notable contributions to detector development for nuclear measurements have been made by Dietz at the Knolls Atomic Power Laboratory, by Barnett at Oak Ridge and by Daly at Atomic Weapons Research Establishment (AWRE), Aldermaston. This paper describes the detection methods which are currently in use at AWRE for isotopic analysis of solid samples for routine applications as well as non-routine applications. Other methods are merely mentioned as a stimulus for discussion.

  10. On the propagation of hydromagnetic waves in a plasma of thermal and suprathermal components

    Science.gov (United States)

    Kumar, Nagendra; Sikka, Himanshu

    2007-12-01

    The propagation of MHD waves is studied when two ideal fluids, thermal and suprathermal gases, coupled by magnetic field are moving with the steady flow velocity. The fluids move independently in a direction perpendicular to the magnetic field but gets coupled along the field. Due to the presence of flow in suprathermal and thermal fluids there appears forward and backward waves. All the forward and backward modes propagate in such a way that their rate of change of phase speed with the thermal Mach number is same. It is also found that besides the usual hydromagnetic modes there appears a suprathermal mode which propagates with faster speed. Surface waves are also examined on an interface formed with composite plasma (suprathermal and thermal gases) on one side and the other is a non-magnetized plasma. In this case, the modes obtained are two or three depending on whether the sound velocity in thermal gas is equal to or greater than the sound velocity in suprathermal gas. The results lead to the conclusion that the interaction of thermal and suprathermal components may lead to the occurrence of an additional mode called suprathermal mode whose phase velocity is higher than all the other modes.

  11. Ion distributions in the Earth's foreshock upstream from the bow shock

    Science.gov (United States)

    Fuselier, S. A.

    1995-01-01

    A variety of suprathermal and energetic ion distributions are found upstream from shocks. Some distributions, such as field-aligned beams, are generated directly at the shock either through reflection processes or through leakage from the hotter downstream region. Other distributions, such as intermediate distributions, evolve from these parent distributions through wave-particle interactions. This paper reviews our current understanding of the creation and evolution of suprathermal distributions at shocks. Examples of suprathermal ion distributions are taken from observations at the Earth's bow shock. Particular emphasis is placed on the creation of field-aligned beams and specularly reflected ion distributions and on the evolution of these distributions in the Earth's ion foreshock. However, the results from this heavily studied region are applicable to interplanetary shocks, bow shocks at other planets, and comets.

  12. ION INJECTION AT QUASI-PARALLEL SHOCKS SEEN BY THE CLUSTER SPACECRAFT

    International Nuclear Information System (INIS)

    Johlander, A.; Vaivads, A.; Khotyaintsev, Yu. V.; Retinò, A.; Dandouras, I.

    2016-01-01

    Collisionless shocks in space plasma are known to be capable of accelerating ions to very high energies through diffusive shock acceleration (DSA). This process requires an injection of suprathermal ions, but the mechanisms producing such a suprathermal ion seed population are still not fully understood. We study acceleration of solar wind ions resulting from reflection off short large-amplitude magnetic structures (SLAMSs) in the quasi-parallel bow shock of Earth using in situ data from the four Cluster spacecraft. Nearly specularly reflected solar wind ions are observed just upstream of a SLAMS. The reflected ions are undergoing shock drift acceleration (SDA) and obtain energies higher than the solar wind energy upstream of the SLAMS. Our test particle simulations show that solar wind ions with lower energy are more likely to be reflected off the SLAMS, while high-energy ions pass through the SLAMS, which is consistent with the observations. The process of SDA at SLAMSs can provide an effective way of accelerating solar wind ions to suprathermal energies. Therefore, this could be a mechanism of ion injection into DSA in astrophysical plasmas

  13. Compact time-zero detector for heavy ions

    International Nuclear Information System (INIS)

    Weissenberger, E.; Kast, W.; Goennenwein, F.

    1979-01-01

    A time-zero detector for flight-time measurements with heavy ions is described. The ions traverse a thin foil and the secondary electrons splashed from the foil are detected in a channel plate multiplier. A timing signal is derived from the multiplier pulse. The novel features of the detector are its simplicity and compactness of design. The time resolution achieved for the full energy and mass span of fission fragments from the spontaneous fission of 252 Cf used as a heavy ion source is 115 ps (fwhm). (Auth.)

  14. Evaluation of hand-held ion-mobility explosives vapor detectors

    International Nuclear Information System (INIS)

    Burrows, T.A.; Thoma, P.J.

    1979-12-01

    Two types of ion-mobility detectors were evaluated in both laboratory and field tests. Laboratory test results show that these detectors are highly sensitive to dynamite and pistol powder and have good false-alarm agent rejection. Field tests of these two detectors revealed that they would detect dynamite and Ball-C-Propellent in free air. However, neither of the ion-mobility detectors would detect these explosives if the explosives were concealed

  15. Alanine Radiation Detectors in Therapeutic Carbon Ion Beams

    DEFF Research Database (Denmark)

    Herrmann, Rochus; Jäkel, Oliver; Palmans, Hugo

    of the depth dose curves. Solid state detectors, such as diamond detectors, radiochromic films, TLDs and the amino acid alanine are used due to there good spatial resolution. If used in particle beams their response often exhibits a dependence on particle energy and type, so the acquired signal is not always...... proportional to absorbed dose. A model by Hansen and Olsen, based on the Track Structure Theory is available, which can predict the relative efficiency of some detectors, when the particle spectrum is known. For alanine detectors the model was successfully validated by Hansen and Olsen for several ion species...... at energies below 20 MeV/u. We implemented this model in the Monte Carlo code FLUKA. At the GSI heavy ion facility in Darmstadt, Germany, alanine has been irradiated with carbon ions at energies between 88 an 400 MeV/u, which is the energy range used for therapy. The irradiation and the detector response have...

  16. Suprathermal protons in the interplanetary solar wind

    Science.gov (United States)

    Goodrich, C. C.; Lazarus, A. J.

    1976-01-01

    Using the Mariner 5 solar wind plasma and magnetic field data, we present observations of field-aligned suprathermal proton velocity distributions having pronounced high-energy shoulders. These observations, similar to the interpenetrating stream observations of Feldman et al. (1974), are clear evidence that such proton distributions are interplanetary rather than bow shock associated phenomena. Large Alfven speed is found to be a requirement for the occurrence of suprathermal proton distribution; further, we find the proportion of particles in the shoulder to be limited by the magnitude of the Alfven speed. It is suggested that this last result could indicate that the proton thermal anisotropy is limited at times by wave-particle interactions

  17. Development of a beam ion velocity detector for the heavy ion beam probe

    International Nuclear Information System (INIS)

    Fimognari, P. J.; Crowley, T. P.; Demers, D. R.

    2016-01-01

    In an axisymmetric plasma, the conservation of canonical angular momentum constrains heavy ion beam probe (HIBP) trajectories such that measurement of the toroidal velocity component of secondary ions provides a localized determination of the poloidal flux at the volume where they originated. We have developed a prototype detector which is designed to determine the beam angle in one dimension through the detection of ion current landing on two parallel planes of detecting elements. A set of apertures creates a pattern of ion current on wires in the first plane and solid metal plates behind them; the relative amounts detected by the wires and plates determine the angle which beam ions enter the detector, which is used to infer the toroidal velocity component. The design evolved from a series of simulations within which we modeled ion beam velocity changes due to equilibrium and fluctuating magnetic fields, along with the ion beam profile and velocity dispersion, and studied how these and characteristics such as the size, cross section, and spacing of the detector elements affect performance.

  18. Development of a beam ion velocity detector for the heavy ion beam probe

    Energy Technology Data Exchange (ETDEWEB)

    Fimognari, P. J., E-mail: PJFimognari@XanthoTechnologies.com; Crowley, T. P.; Demers, D. R. [Xantho Technologies, LLC, Madison, Wisconsin 53705 (United States)

    2016-11-15

    In an axisymmetric plasma, the conservation of canonical angular momentum constrains heavy ion beam probe (HIBP) trajectories such that measurement of the toroidal velocity component of secondary ions provides a localized determination of the poloidal flux at the volume where they originated. We have developed a prototype detector which is designed to determine the beam angle in one dimension through the detection of ion current landing on two parallel planes of detecting elements. A set of apertures creates a pattern of ion current on wires in the first plane and solid metal plates behind them; the relative amounts detected by the wires and plates determine the angle which beam ions enter the detector, which is used to infer the toroidal velocity component. The design evolved from a series of simulations within which we modeled ion beam velocity changes due to equilibrium and fluctuating magnetic fields, along with the ion beam profile and velocity dispersion, and studied how these and characteristics such as the size, cross section, and spacing of the detector elements affect performance.

  19. Suprathermal electron studies in Tokamak plasmas by means of diagnostic measurements and modeling

    International Nuclear Information System (INIS)

    Kamleitner, J.

    2015-01-01

    To achieve reactor-relevant conditions in a tokamak plasma, auxiliary heating systems are required and can be realized by waves injected in the plasma that heat ions or electrons. Electron cyclotron resonant heating (ECRH) is a very flexible and robust technique featuring localized power deposition and current drive (CD) capabilities. Its fundamental principles are well understood and the application of ECRH is a proven and established tool; electron cyclotron current drive (ECCD) is regularly used to develop advanced scenarios and control magneto-hydrodynamics (MHD) instabilities in the plasma by tailoring the current profile. There remain important open questions, such as the phase space dynamics, the observed radial broadening of the supra-thermal electron distribution function and discrepancies in predicted and experimental CD efficiency. A main goal is to improve the understanding of wave-particle interaction in plasmas and current drive mechanisms. This was accomplished by combined experimental and numerical studies, strongly based on the conjunction of hard X-ray (HXR) Bremsstrahlung measurements and Fokker-Planck modelling, characterizing the supra-thermal electron population. The hard X-ray tomographic spectrometer (HXRS) diagnostic was developed to perform these studies by investigating spatial HXR emission asymmetries in the co- and counter-current directions and within the poloidal plane. The system uses cadmium-telluride detectors and digital acquisition to store the complete time history of incoming photon pulses. An extensive study of digital pulse processing algorithms was performed and its application allows the HXRS to handle high count rates in a noisy tokamak environment. Numerical tools were developed to improve the time resolution by conditional averaging and to obtain local information with the general tomographic inversion package. The interfaces of the LUKE code and the well-established CQL3D Fokker-Planck code to the Tokamak a

  20. Subnanosecond timing with ion-implanted detectors

    International Nuclear Information System (INIS)

    Rijken, H.A.; Klein, S.S.; Jacobs, W.; Teeuwen, L.J.H.G.W.; Voigt, M.J.A. de; Burger, P.

    1992-01-01

    The energy resolution of ion-implanted charged particle detectors may be improved by decreasing the thickness of the implanted detector window to minimize energy straggling. Because of the resistance of this layer, however, the timing depends on the position of entry. Two solutions to this conflict between energy resolution and time resolution are studied: evaporating a very thin aluminum layer on the detector window and fabricating a rectangular detector. Both solutions are shown to be successful with a total time resolution in the low subnanosecond region (<200 ps). (orig.)

  1. Characteristics for heavy ions and micro-dosimetry in radiation detectors

    International Nuclear Information System (INIS)

    Doke, Tadayoshi

    1978-01-01

    The characteristics of radiation detectors for heavy ions generally present more complex aspects as compared with those for electron beam and γ-ray. There is the ''Katz theory'' applying the target theory in radiobiology phenomenologically to radiation detectors. Here, first, the Katz theory for radiation detectors is explained, then its applications to nuclear plates, solid state track detectors, scintillation detectors and thermoluminescence dosimeters are described, respectively. The theory is used for the calibration of the nuclear charge of heavy ions in nuclear plates and recently is used to simulate the flight tracks of heavy ions or magnetic monopoles. In solid state track detectors, the threshold value of the energy given along the tracks of heavy ions is inherent to a detector, and the Katz theory is applicable as the measure of the threshold. The theory seems to be superior to the other methods. However, it has disadvantages that the calculation is not simple and is difficult for wide objects. In scintillation detectors, the scintillation efficiency is not a single function of dE/dx, but depends on the kinds of heavy ions, which Katz succeeded to describe quantitatively with his theory. Such result has also been produced that the dependence of thermoluminescence dosimeters such as LiF on LET by Katz theory agreed fairly well with experiments. (Wakatsuki, Y.)

  2. A method to measure the suprathermal density distribution by electron cyclotron emission

    International Nuclear Information System (INIS)

    Tutter, M.

    1986-05-01

    Electron cyclotron emission spectra of suprathermal electrons in a thermal main plasma are calculated. It is shown that for direction of observation oblique to the magnetic field, which decays in direction to the receiver, one may obtain information on the spatial density distribution of the suprathermal electrons from those spectra. (orig.)

  3. Detector issues for relativistic heavy ion experimentation

    International Nuclear Information System (INIS)

    Gordon, H.

    1986-04-01

    Several aspects of experiments using relativistic heavy ion beams are discussed. The problems that the current generation of light ion experiments would face in using gold beams are noted. A brief review of colliding beam experiments for heavy ion beams is contrasted with requirements for SSC detectors. 11 refs., 13 figs

  4. Low pressure gas detectors for molecular-ion break up studies

    International Nuclear Information System (INIS)

    Breskin, A.; Chechik, R.; Zwang, N.

    1981-01-01

    Two detector systems for Molecular ions like OH + and CH 2 + and like H 2 + and H 3 + were developed and are described. The first detector is installed in a magnetic spectrometer. Both systems are made of various types of gas detectors operating at low pressures. In the study of the Coulomb explosion of molecular ions like OH + , CH 2 + or H 3 + these detectors provide the position and time coordinates of all the fragments of the molecular ion, in coincidence, in order to determine their energy and angular distribution. In the case of molecules containing atoms other than hydrogen, information on the electronic charge state is obtained. (H.K.)

  5. 5D simulation study of suprathermal electron transport in non-axisymmetric plasmas

    International Nuclear Information System (INIS)

    Murakami, S.; Idei, H.; Kubo, S.; Nakajima, N.; Okamoto, M.; Gasparino, U.; Maassberg, H.; Rome, M.; Marushchenko, N.

    2001-01-01

    ECRH-driven transport of is studied in using a new Monte Carlo simulation technique in 5D phase space. Two different phases of the ECRH-driven transport of suprathermal electrons can be seen; one is a rapid convective phase due to the direct radial motion of trapped electrons and the other is a slower phase due to the collisional transport. The important role of the radial transport of suprathermal electrons in the broadening of the ECRH deposition profile is clarified in W7-AS. The ECRH driven flux is also evaluated and put in relation with the ''electron root'' feature recently observed in W7-AS. It is found that, at low collisionalities, the ECRH driven flux due to the suprathermal electrons can play a dominant role in the condition of ambipolarity and, thus, the observed ''electron root'' feature in W7-AS is thought to be driven by the radial (convective) flux of ECRH generated suprathermal electrons. The possible scenario of this ''ECRH-driven electron root'' is considered in the LHD plasma. (author)

  6. 326 Ion-spraying type atmospheric radon detector

    International Nuclear Information System (INIS)

    Wu Xinmin; Liu Qingchen; Liu Yujuan; Li Shumin; Yang Yaxin

    2005-01-01

    The advantages and disadvantages of atmospheric absolute radon detector were briefly analyzed in this paper. The working principle, structure and main technical capability of the 326 ion-spraying type atmospheric radon detector were introduced. Finally, its disadvantages and the improved aspects in the future were discussed. (authors)

  7. Development of noise-suppressed detector for single ion hit system

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Takuro; Hamano, Tsuyoshi; Suda, Tamotsu; Hirao, Toshio; Kamiya, Tomihiro [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    A noise-suppressed detector for single ion detection has been developed, and combined with the heavy ion microbeam apparatus. This detector consists of a pair of micro channel plates (MCP`s) and a very thin carbon foil. The detection signal is formed by the coincidence of the signals from these MCP`s, so that this detector and the coincidence measurement unit can reduce miscounting in the circuit. The detection efficiency for 15 MeV heavy ions was evaluated to be comparable to that of a silicon surface-barrier detector (SSD) and the miscounting rate was 4 orders lower than the noise rate of a single MCP. The rise time of the detection signal was also estimated. (author)

  8. On the use of thin ion implanted Si detectors in heavy ion experiments

    International Nuclear Information System (INIS)

    Lavergne-Gosselin, L.; Stab, L.; Lampert, M.O.

    1988-10-01

    We present test results on the use of thin ion implanted epitaxial Si detectors for registration of low- and medium energy heavy fragments in nuclear reactions. A linear energy response for very low energy nuclei has been observed. A test of 10 μm + 300 μm telescopes under realistic experimental conditions for heavy ion experiments exhibits the possibilities to use these detectors for the measurements of multifragmentation products. (authors)

  9. Microscope mode secondary ion mass spectrometry imaging with a Timepix detector.

    NARCIS (Netherlands)

    Kiss, A.; Jungmann, JH; Smith, D.F.; Heeren, R.M.A.

    2013-01-01

    In-vacuum active pixel detectors enable high sensitivity, highly parallel time- and space-resolved detection of ions from complex surfaces. For the first time, a Timepix detector assembly was combined with a secondary ion mass spectrometer for microscope mode secondary ion mass spectrometry (SIMS)

  10. Heavy ion measurements by use of chemical detectors

    International Nuclear Information System (INIS)

    Huebner, K.; Erzgraeber, G.; Eichhorn, K.

    1980-01-01

    In order to test whether the threshold system polyvinyl alcohol/methyl organe/chloral hydrate/sodium tetraborate permits quantitative detection of individual particles, the chemical detector was irradiated at the JINR U-200 cyclotron with 4 He, 12 C, 18 O, 22 Ne ions having different LET. Irradiations were performed with detectors of four different borax concentrations (the chloral hydrate concentration being constant). The colour change dose Dsub(u) increases linearly with increasing borax concentration and at constant borax concentration with increasing LET. Hence it follows that the G value of dehydrochlorination decreases with increasing LET. Fluence ranges measurable with detectors of different composition are given for the heavy ions studied. (author)

  11. Low-temperature technique of thin silicon ion implanted epitaxial detectors

    Energy Technology Data Exchange (ETDEWEB)

    Kordyasz, A.J.; Bednarek, A. [Warsaw University, Heavy Ion Laboratory, Warsaw (Poland); Le Neindre, N.; Bougault, R.; Lopez, O.; Merrer, Y.; Vient, E. [Universite de Caen, LPC, IN2P3-CNRS, ENSICAEN, Caen-Cedex (France); Parlog, M. [Universite de Caen, LPC, IN2P3-CNRS, ENSICAEN, Caen-Cedex (France); ' ' Horia Hulubei' ' National Institute of Physics and Nuclear Engineering (IFIN-HH), Bucharest Magurele (Romania); Casini, G.; Poggi, G.; Bini, M.; Valdre, S.; Scarlini, E.; Pasquali, G.; Pastore, G.; Piantelli, S.; Stefanini, A.; Olmi, A.; Barlini, S. [INFN Firenze, Sesto Fiorentino (Italy); Universita di Firenze, Sesto Fiorentino (Firenze) (Italy); Kowalczyk, M. [Warsaw University, Heavy Ion Laboratory, Warsaw (Poland); University of Warsaw, Institute of Experimental Physics, Warsaw (Poland); Frankland, J.D.; Bonnet, E.; Chbihi, A.; Gruyer, D. [CEA et IN2P3-CNRS, GANIL, Caen-Cedex 05 (France); Borderie, B.; Ademard, G.; Edelbruck, P.; Rivet, M.F.; Salomon, F. [IN2P3-CNRS, Institut de Physique Nucleaire, Orsay-Cedex (France); Boiano, A.; Rosato, E.; Meoli, A.; Ordine, A.; Spadaccini, G.; Tortone, G.; Vigilante, M.; Vanzanella, E. [Universita di Napoli ' ' Federico II' ' , Dipartimento di Scienze Fisiche, Napoli (Italy); INFN, Napoli (Italy); Bruno, M.; Serra, S.; Morelli, L.; Guerzoni, M. [INFN, Bologna (Italy); Universita di Bologna, Bologna (Italy); Alba, R.; Santonocito, D.; Maiolino, C. [INFN, Catania (Italy); Universita di Catania, LNS, Catania (Italy); Cinausero, M.; Gramegna, F.; Marchi, T. [INFN LNL Legnaro, Legnaro (Padova) (Italy); Kozik, T.; Kulig, P.; Twarog, T.; Sosin, Z. [Jagiellonian University, Cracow (Poland); Gasior, K.; Grzeszczuk, A.; Zipper, W. [University of Silesia, Silesian University, Katowice (Poland); Sarnecki, J.; Lipinski, D.; Wodzinska, H.; Brzozowski, A.; Teodorczyk, M.; Gajewski, M.; Zagojski, A.; Krzyzak, K. [Institute of Electronic Materials Technology, Warsaw (Poland); Tarasiuk, K.J. [University of Warsaw, Institute of Experimental Physics, Warsaw (Poland); Khabanowa, Z. [Faculty of Physics, Warsaw University of Technology, Warsaw (Poland); Kordyasz, L. [Warsaw University of Technology, Faculty of Mechatronics, Institute of Mikromechanics and Photonics, Department of Design of Precision Devices, Warsaw (Poland)

    2015-02-01

    A new technique of large-area thin ion implanted silicon detectors has been developed within the R and D performed by the FAZIA Collaboration. The essence of the technique is the application of a low-temperature baking process instead of high-temperature annealing. This thermal treatment is performed after B{sup +} ion implantation and Al evaporation of detector contacts, made by using a single adjusted Al mask. Extremely thin silicon pads can be therefore obtained. The thickness distribution along the X and Y directions was measured for a prototype chip by the energy loss of α-particles from {sup 241}Am (left angle E{sub α} right angle = 5.5 MeV). Preliminary tests on the first thin detector (area ∼ 20 x 20 mm{sup 2}) were performed at the INFN-LNS cyclotron in Catania (Italy) using products emitted in the heavy-ion reaction {sup 84}Kr (E = 35 A MeV) + {sup 112}Sn. The ΔE - E ion identification plot was obtained using a telescope consisting of our thin ΔE detector (21 μm thick) followed by a typical FAZIA 510 μm E detector of the same active area. The charge distribution of measured ions is presented together with a quantitative evaluation of the quality of the Z resolution. The threshold is lower than 2 A MeV depending on the ion charge. (orig.)

  12. Ion-ion coincidence imaging at high event rate using an in-vacuum pixel detector

    Science.gov (United States)

    Long, Jingming; Furch, Federico J.; Durá, Judith; Tremsin, Anton S.; Vallerga, John; Schulz, Claus Peter; Rouzée, Arnaud; Vrakking, Marc J. J.

    2017-07-01

    A new ion-ion coincidence imaging spectrometer based on a pixelated complementary metal-oxide-semiconductor detector has been developed for the investigation of molecular ionization and fragmentation processes in strong laser fields. Used as a part of a velocity map imaging spectrometer, the detection system is comprised of a set of microchannel plates and a Timepix detector. A fast time-to-digital converter (TDC) is used to enhance the ion time-of-flight resolution by correlating timestamps registered separately by the Timepix detector and the TDC. In addition, sub-pixel spatial resolution (principle experiment on strong field dissociative double ionization of carbon dioxide molecules (CO2), using a 400 kHz repetition rate laser system. The experimental results demonstrate that the spectrometer can detect multiple ions in coincidence, making it a valuable tool for studying the fragmentation dynamics of molecules in strong laser fields.

  13. Near midplane scintillator-based fast ion loss detector on DIII-D.

    Science.gov (United States)

    Chen, X; Fisher, R K; Pace, D C; García-Muñoz, M; Chavez, J A; Heidbrink, W W; Van Zeeland, M A

    2012-10-01

    A new scintillator-based fast-ion loss detector (FILD) installed near the outer midplane of the plasma has been commissioned on DIII-D. This detector successfully measures coherent fast ion losses produced by fast-ion driven instabilities (≤500 kHz). Combined with the first FILD at ∼45° below the outer midplane [R. K. Fisher, et al., Rev. Sci. Instrum. 81, 10D307 (2010)], the two-detector system measures poloidal variation of losses. The phase space sensitivity of the new detector (gyroradius r(L) ∼ [1.5-8] cm and pitch angle α ∼ [35°-85°]) is calibrated using neutral beam first orbit loss measurements. Since fast ion losses are localized poloidally, having two FILDs at different poloidal locations allows for the study of losses over a wider range of plasma shapes and types of loss orbits.

  14. Ion smoke detector

    International Nuclear Information System (INIS)

    Basset, Georges.

    1976-01-01

    This invention covers an ion smoke detector in which the capacity that the smoke will cross, in the event of an accident, is irradiated by a very low energy radioactive source. The gas in the containment is thus partially ionised. Smoke in this containment reduces the mobility of the ions, thereby increasing the impedance of the measuring chamber. A leak tight reference chamber that therefore receives no smoke is added to the measuring chamber. This chamber is filled with the same gas as that present in the measuring chamber and undergoes the same irradiation. It is of course subjected to the same conditions of temperature, atmospheric pressure and hygrometry as the measuring chamber. This makes it possible to break free from the fluctuations of the impedance of the chamber which would seem to be due to these interferences. One only radioactive source irradiates the measuring chamber and the reference chamber. The measuring chamber is in the shape of a cylinder open at one end and the reference chamber is annular and encompasses the measuring chamber. Provision is made for detecting an increase in the potential across the terminals of the measuring chamber in relation to the reference chamber, which is characteristic of the presence of smoke and other provisions separate from the former for dectecting a reduction in potential between the electrodes of the first ionisation chamber, which is characteristic of a change in the detector [fr

  15. SU-D-BRB-02: Investigations of Secondary Ion Distributions in Carbon Ion Therapy Using the Timepix Detector.

    Science.gov (United States)

    Gwosch, K; Hartmann, B; Jakubek, J; Granja, C; Soukup, P; Jaekel, O; Martisikova, M

    2012-06-01

    Due to the high conformity of carbon ion therapy, unpredictable changes in the patient's geometry or deviations from the planned beam properties can result in changes of the dose distribution. PET has been used successfully to monitor the actual dose distribution in the patient. However, it suffers from biological washout processes and low detection efficiency. The purpose of this contribution is to investigate the potential of beam monitoring by detection of prompt secondary ions emerging from a homogeneous phantom, simulating a patient's head. Measurements were performed at the Heidelberg Ion-Beam Therapy Center (Germany) using a carbon ion pencil beam irradiated on a cylindrical PMMA phantom (16cm diameter). For registration of the secondary ions, the Timepix detector was used. This pixelated silicon detector allows position-resolved measurements of individual ions (256×256 pixels, 55μm pitch). To track the secondary ions we used several parallel detectors (3D voxel detector). For monitoring of the beam in the phantom, we analyzed the directional distribution of the registered ions. This distribution shows a clear dependence on the initial beam energy, width and position. Detectable were range differences of 1.7mm, as well as vertical and horizontal shifts of the beam position by 1mm. To estimate the clinical potential of this method, we measured the yield of secondary ions emerging from the phantom for a beam energy of 226MeV/u. The differential distribution of secondary ions as a function of the angle from the beam axis for angles between 0 and 90° will be presented. In this setup the total yield in the forward hemisphere was found to be in the order of 10 -1 secondary ions per primary carbon ion. The presented measurements show that tracking of secondary ions provides a promising method for non-invasive monitoring of ion beam parameters for clinical relevant carbon ion fluences. Research with the pixel detectors was carried out in frame of the Medipix

  16. Determination of the energy of suprathermal electrons during lower hybrid current drive on PBX-M

    International Nuclear Information System (INIS)

    von Goeler, S.; Bernabei, S.; Davis, W.; Ignat, D.; Kaita, R.; Roney, P.; Stevens, J.; Post-Zwicker, A.

    1993-06-01

    Suprathermal electrons are diagnosed by a hard x-ray pinhole camera during lower hybrid current drive on PBX-M. The experimental hard x-ray images are compared with simulated images, which result from an integration of the relativistic bremsstrahlung along lines-of-sight through the bean-shaped plasma. Images with centrally peaked and radially hollow radiation profiles are easily distinguished. The energy distribution of the suprathermal electrons is analyzed by comparing images taken with different absorber foils. An effective photon temperature is derived from the experimental images, and a comparison with simulated photon temperatures yields the energy of the suprathermal electrons. The analysis indicates that the energy of the suprathermal electrons in the hollow discharges is in the 50 to 100 key range in the center of the discharge. There seems to exist a very small higher energy component close to the plasma edge

  17. Suprathermal fusion reactions in laser-imploded D-T pellets. Applicability to pellet diagnosis and necessity of nuclear data

    International Nuclear Information System (INIS)

    Tabaru, Y.; Nakao, Y.; Kudo, K.; Nakashima, H.

    1995-01-01

    The suprathermal fusion reaction is examined on the basis of coupled transport/hydrodynamic calculation. We also calculate the energy spectrum of neutrons bursting from DT pellet. Because of suprathermal fusion and rapid pellet expansion, these neutrons contain fast components whose maximum energy reachs about 40 MeV. The pellet ρR diagnosis by the detection of suprathermal fusion neutrons is discussed. (author)

  18. Future Perspectives for the Application of Low Temperature Detectors in Heavy Ion Physics

    International Nuclear Information System (INIS)

    Egelhof, P.; Kraft-Bermuth, S.

    2009-01-01

    Calorimetric low temperature detectors have the potential to become powerful tools for applications in many fields of heavy ion physics. A brief overview of heavy ion physics is given, and the next generation heavy ion facility FAIR is described with a special emphasis on the potential advantage of Low Temperature Detectors (LTDs) for applications in heavy ion physics. For prototype LTDs for the energy sensitive detection of heavy ions excellent results with respect to energy resolution down to δE/E = 1-2x10 -3 for a wide range of incident energies, and with respect to other detector properties, such as energy linearity with no indication of pulse height defects even for the heaviest ions, have been obtained. In addition, prototype detectors for hard X-rays have shown energy resolutions down to δE = 30-40eV at 60 keV. Consequently, both detector schemes have already been successfully used for first experiments. At present, the design and setup of large solid angle detector arrays is in progress. With the already achieved performance, LTDs promise a large potential for applications in atomic and nuclear heavy ion physics. A brief overview of prominent examples, including high-resolution nuclear spectroscopy, nuclear structure studies with radioactive beams, superheavy element research, as well as high-resolution atomic spectroscopy on highly charged ions and tests of QED in strong electromagnetic fields is presented.

  19. Design of Faraday cup ion detectors built by thin film deposition

    Energy Technology Data Exchange (ETDEWEB)

    Szalkowski, G.A., E-mail: gszalkowski3@gatech.edu [Department of Nuclear Engineering, Georgia Institute of Technology, 770 State St., Atlanta, GA 30332 (United States); Darrow, D.S., E-mail: ddarrow@pppl.gov [Princeton Plasma Physics Laboratory, P. O. Box 451, Princeton, NJ 08543 (United States); Cecil, F.E., E-mail: fcecil@mines.edu [Department of Physics, Colorado School of Mines, Golden, CO 80401 (United States)

    2017-03-11

    Thin film Faraday cup detectors can provide measurements of fast ion loss from magnetically confined fusion plasmas. These multilayer detectors can resolve the energy distribution of the lost ions in addition to giving the total loss rate. Prior detectors were assembled from discrete foils and insulating sheets. Outlined here is a design methodology for creating detectors using thin film deposition that are suited to particular scientific goals. The intention is to use detectors created by this method on the Joint European Torus (JET) and the National Spherical Torus Experiment-Upgrade (NSTX-U). The detectors will consist of alternating layers of aluminum and silicon dioxide, with layer thicknesses chosen to isolate energies of interest. Thin film deposition offers the advantage of relatively simple and more mechanically robust construction compared to other methods, as well as allowing precise control of film thickness. Furthermore, this depositional fabrication technique places the layers in intimate thermal contact, providing for three-dimensional conduction and dissipation of the ion-produced heating in the layers, rather than the essentially two-dimensional heat conduction in the discrete foil stack implementation.

  20. Plasma-laser ion discrimination by TOF technique applied to coupled SiC detectors.

    Science.gov (United States)

    Cavallaro, Salvatore

    2018-01-01

    The rate estimation of nuclear reactions induced in high intensity laser-target interaction (≥1016 W/cm2), is strongly depending on the neutron detection efficiency and ion charge discrimination, according to particles involved in exit open-channels. Ion discrimination is basically performed by means of analysis of pits observed on track detector, which is critically dependent on calibration and/or fast TOF devices based on SiC and diamond detectors. Last setup is used to determine the ion energy and to obtain a rough estimation of yields. However, for each TOF interval, the dependence of yield from the energy deposited in the detector sensitive region, introduces a distortion in the ion spectra. Moreover, if two ion species are present in the same spectrum, the discrimination of their contribution is not attainable. In this paper a new method is described which allows to discriminate the contribution of two ion species in the wide energy range of nuclear reactions induced in laser-target interactions. The method is based on charge response of two TOF-SiC detectors, of suitable thicknesses, placed in adjacent positions. In presence of two ion species, the response of the detectors, associated with different energy losses, can determine the ion specific contribution to each TOF interval.

  1. High-resolution ion-implanted silicon detectors

    International Nuclear Information System (INIS)

    von Borany, J.; Schmidt, B.

    1985-01-01

    An account is given of the properties of silicon detectors developed at the Central Institute of Nuclear Research of the Academy of Sciences of the German Democratic Republic (Rossendorf) and made by a special planar technology using ion implantation, anodic oxidation, thermal oxidation in an oxygen atmosphere containing HCl, and annealing by pulses of 10--20 msec duration. The resolution for α particles of 5.5 MeV energy was 11.2 keV (active area A 2 ). The detectors were characterized by a low intrinsic noise (< or =5 keV), so that they could be used for spectrometry of low-energy electrons (E/sub e/< or =250 keV). In a certain range of energies (E/sub x/ = 15--60 keV) it was possible to use these detectors for spectrometry of x rays at room temperature. Examples and results of applications of detectors in radiation chemistry (investigations of backscattering of particles and nuclear reaction spectroscopy) are given. The feasibility of annealing of radiation defects in such detectors after irradiation with a large dose of charged particles is considered

  2. Conceptual design of the ITER fast-ion loss detector

    International Nuclear Information System (INIS)

    Garcia-Munoz, M.; Ayllon-Guerola, J.; Galdon, J.; Garcia Lopez, J.; Gonzalez-Martin, J.; Jimenez-Ramos, M. C.; Rodriguez-Ramos, M.; Rivero-Rodriguez, J. F.; Sanchis-Sanchez, L.; Kocan, M.; Bertalot, L.; Bonnet, Y.; Casal, N.; Giacomin, T.; Pinches, S. D.; Reichle, R.; Vayakis, G.; Veshchev, E.; Vorpahl, Ch.; Walsh, M.

    2016-01-01

    A conceptual design of a reciprocating fast-ion loss detector for ITER has been developed and is presented here. Fast-ion orbit simulations in a 3D magnetic equilibrium and up-to-date first wall have been carried out to revise the measurement requirements for the lost alpha monitor in ITER. In agreement with recent observations, the simulations presented here suggest that a pitch-angle resolution of ∼5° might be necessary to identify the loss mechanisms. Synthetic measurements including realistic lost alpha-particle as well as neutron and gamma fluxes predict scintillator signal-to-noise levels measurable with standard light acquisition systems with the detector aperture at ∼11 cm outside of the diagnostic first wall. At measurement position, heat load on detector head is comparable to that in present devices.

  3. Conceptual design of the ITER fast-ion loss detector

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Munoz, M., E-mail: mgm@us.es; Ayllon-Guerola, J.; Galdon, J.; Garcia Lopez, J.; Gonzalez-Martin, J.; Jimenez-Ramos, M. C.; Rodriguez-Ramos, M.; Rivero-Rodriguez, J. F.; Sanchis-Sanchez, L. [Department of Atomic, Molecular and Nuclear Physics, University of Seville, 41012 Seville (Spain); CNA (Universidad de Sevilla-CSIC-J. Andalucía), Seville (Spain); Kocan, M.; Bertalot, L.; Bonnet, Y.; Casal, N.; Giacomin, T.; Pinches, S. D.; Reichle, R.; Vayakis, G.; Veshchev, E.; Vorpahl, Ch.; Walsh, M. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 Saint Paul-lez-Durance Cedex (France); and others

    2016-11-15

    A conceptual design of a reciprocating fast-ion loss detector for ITER has been developed and is presented here. Fast-ion orbit simulations in a 3D magnetic equilibrium and up-to-date first wall have been carried out to revise the measurement requirements for the lost alpha monitor in ITER. In agreement with recent observations, the simulations presented here suggest that a pitch-angle resolution of ∼5° might be necessary to identify the loss mechanisms. Synthetic measurements including realistic lost alpha-particle as well as neutron and gamma fluxes predict scintillator signal-to-noise levels measurable with standard light acquisition systems with the detector aperture at ∼11 cm outside of the diagnostic first wall. At measurement position, heat load on detector head is comparable to that in present devices.

  4. Structure of Ion Outflow in the Martian Magnetotail

    Science.gov (United States)

    McFadden, J. P.; Mitchell, D.; Luhmann, J. G.; Connerney, J. E. P.; Jakosky, B. M.

    2017-12-01

    The Suprathermal And Thermal Ion Composition (STATIC) sensor on the MAVEN spacecraft provides a detailed look at the structure of ion outflow in the Martian magnetotail including ion composition, energization, and flow. Mars' magnetotail contains a mixture of cold (multi-species ions, tailward-moving cold multi-species ions, suprathermal ions of a few tens of eV, warm (about 100 eV) proton populations, and heavy (primarily O+) pickup ions at energies from 1 to 10 keV which may display several simultaneous peaks in energy flux. The cold tailward-moving ions represent a significant fraction of the Martian ion loss, perhaps comparable to loses from molecular oxygen dissociation. The suprathermal tail that accompanies the cold ions varies greatly and provides clues to ion escape. The warm protons, on first examination, appear to be of sheath origin, displaying a similar energy distribution and accompanied by a tenuous warm population at M/Q=2 (which could be either solar wind alphas or molecular hydrogen ions of ionospheric origin). STATIC produces a weak ghost peak at M/Q=11-12 when observing molecular hydrogen ions, but not alphas, often allowing the instrument to distinguish the source of protons. Measurements show the warm protons are of ionospheric origin in the central tail and transition to sheath plasma in the umbra. Energetic (1-10 keV) pickup oxygen in the magnetotail is produced on the nightside, near the pole where the IMF convection electric field points toward the planet, the same hemisphere where sputtering occurs. When two spectral peaks are observed, these tailward-moving ions differ in direction by relatively small angles (about 20 degrees). These peaks can persist for tens of minutes indicating approximately time-stationary acceleration, and therefore acceleration in potential fields. Magnetotail structure and geometry can be inferred not only from the local magnetic field, but also from the measured electron distributions which indicate source

  5. A physical mechanism producing suprathermal populations and initiating substorms in the Earth's magnetotail

    Directory of Open Access Journals (Sweden)

    D. V. Sarafopoulos

    2008-06-01

    Full Text Available We suggest a candidate physical mechanism, combining there dimensional structure and temporal development, which is potentially able to produce suprathermal populations and cross-tail current disruptions in the Earth's plasma sheet. At the core of the proposed process is the "akis" structure; in a thin current sheet (TCS the stretched (tail-like magnetic field lines locally terminate into a sharp tip around the tail midplane. At this sharp tip of the TCS, ions become non-adiabatic, while a percentage of electrons are accumulated and trapped: The strong and transient electrostatic electric fields established along the magnetic field lines produce suprathermal populations. In parallel, the tip structure is associated with field aligned and mutually attracted parallel filamentary currents which progressively become more intense and inevitably the structure collapses, and so does the local TCS. The mechanism is observationally based on elementary, almost autonomous and spatiotemporal entities that correspond each to a local thinning/dipolarization pair having duration of ~1 min. Energetic proton and electron populations do not occur simultaneously, and we infer that they are separately accelerated at local thinnings and dipolarizations, respectively. In one example energetic particles are accelerated without any dB/dt variation and before the substorm expansion phase onset. A particular effort is undertaken demonstrating that the proposed acceleration mechanism may explain the plasma sheet ratio Ti/Te≈7. All our inferences are checked by the highest resolution datasets obtained by the Geotail Energetic Particles and Ion Composition (EPIC instrument. The energetic particles are used as the best diagnostics for the accelerating source. Near Earth (X≈10 RE selected events support our basic concept. The proposed mechanism seems to reveal a fundamental building block of the substorm phenomenon and may be the basic process/structure, which is now

  6. Oxygen ion implantation induced microstructural changes and electrical conductivity in Bakelite RPC detector material

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, K. V. Aneesh, E-mail: aneesh1098@gmail.com; Ravikumar, H. B., E-mail: hbr@physics.uni-mysore.ac.in [Department of Studies in Physics, University of Mysore, Mysore-570006 (India); Ranganathaiah, C., E-mail: cr@physics.uni-mysore.ac.in [Govt. Research Centre, Sahyadri Educational Institutions, Mangalore-575007 (India); Kumarswamy, G. N., E-mail: kumy79@gmail.com [Department of Studies in Physics, Amrita Vishwa Vidyapeetham, Bangalore-560035 (India)

    2016-05-06

    In order to explore the structural modification induced electrical conductivity, samples of Bakelite Resistive Plate Chamber (RPC) detector materials were exposed to 100 keV Oxygen ion in the fluences of 10{sup 12}, 10{sup 13}, 10{sup 14} and 10{sup 15} ions/cm{sup 2}. Ion implantation induced microstructural changes have been studied using Positron Annihilation Lifetime Spectroscopy (PALS) and X-Ray Diffraction (XRD) techniques. Positron lifetime parameters viz., o-Ps lifetime and its intensity shows the deposition of high energy interior track and chain scission leads to the formation of radicals, secondary ions and electrons at lower ion implantation fluences (10{sup 12} to10{sup 14} ions/cm{sup 2}) followed by cross-linking at 10{sup 15} ions/cm{sup 2} fluence due to the radical reactions. The reduction in electrical conductivity of Bakelite detector material is correlated to the conducting pathways and cross-links in the polymer matrix. The appropriate implantation energy and fluence of Oxygen ion on polymer based Bakelite RPC detector material may reduce the leakage current, improves the efficiency, time resolution and thereby rectify the aging crisis of the RPC detectors.

  7. Applications of CR-39 solid state nuclear track detector to ion beam diagnosis

    International Nuclear Information System (INIS)

    Kanasaki, Masato; Hattori, Atsuto; Oda, Keiji; Yamauchi, Tomoya; Fukuda, Yuji; Sakaki, Hironao; Nishiuchi, Mamiko; Kondo, Kiminori; Kurashima, Satoshi; Kamiya, Tomihiro

    2012-01-01

    CR-39 solid state nuclear track detector, which was developed for optical lens, has been applied for various field such as radon surveys, measurement of galactic cosmic ray, cell irradiation experiment and so on. The CR-39 detectors have the great advantages of being insensitive to high energy photons and electrons and capable of detecting only ions in the mixed fields such as laser driven relativistic plasmas. Though there are some analytical methods of CR-39 to diagnose ion beam, unfortunately, only few researchers in the field of plasma know the methods. This article looks at how to use CR-39 detectors and introduce the accomplishment of the joint study JAEA and Kobe Univ. for application of CR-39 detectors to ion beam diagnosis. (author)

  8. Measurement of negative ion mobility in O2 at high pressures using a point plate gap as an ion detector

    International Nuclear Information System (INIS)

    Okuyama, Y; Kimura, T; Suzuki, S; Itoh, H

    2012-01-01

    This paper describes the experimental results for negative ion mobility in O 2 at 0.5-2.0 atm. The ion mobility is observed using a high-pressure ion drift tube with a positive corona gap (Geiger counter), which is constructed from a point plate gap and acts as a negative ion detector. The variation of waveforms in the burst pulse is observed by varying the voltage applied to the ion detector to find the optimum voltage that must be applied across the ion detector in O 2 . This is investigated carefully to ensure the precise determination of mobility. The distortion of the electric field near the mesh electrode, which operates as the cathode of the ion detector and as the anode of the ion drift gap, is then examined to determine the optimum applied voltage to suppress its effect on the measurement of mobility. The mobility is subsequently measured at a reduced electric field intensity of 2.83 × 10 -3 to 2.83. The observed mobility of 2.31 ± 0.03 cm 2 V -1 s -1 in O 2 is concluded to be that of O 2 - . This value is also obtained in experiments over a wide range of gas pressures (0.5-2.0 atm) and drift lengths (1.00-9.00 cm). The mobilities of O 3 - and O - are also obtained experimentally. (paper)

  9. Dose Response of Alanine Detectors Irradiated with Carbon Ion Beams

    DEFF Research Database (Denmark)

    Herrmann, Rochus; Jäkel, Oliver; Palmans, Hugo

    2011-01-01

    Purpose: The dose response of the alanine detector shows a dependence on particle energy and type, when irradiated with ion beams. The purpose of this study is to investigate the response behaviour of the alanine detector in clinical carbon ion beams and compare the results with model predictions......-dose curves deviate from predictions in the peak region, most pronounced at the distal edge of the peak. Conclusions: The used model and its implementation show a good overall agreement for quasi mono energetic measurements. Deviations in depth-dose measurements are mainly attributed to uncertainties...

  10. Single ion implantation for single donor devices using Geiger mode detectors

    International Nuclear Information System (INIS)

    Bielejec, E; Seamons, J A; Carroll, M S

    2010-01-01

    Electronic devices that are designed to use the properties of single atoms such as donors or defects have become a reality with recent demonstrations of donor spectroscopy, single photon emission sources, and magnetic imaging using defect centers in diamond. Ion implantation, an industry standard for atom placement in materials, requires augmentation for single ion capability including a method for detecting a single ion arrival. Integrating single ion detection techniques with the single donor device construction region allows single ion arrival to be assured. Improving detector sensitivity is linked to improving control over the straggle of the ion as well as providing more flexibility in lay-out integration with the active region of the single donor device construction zone by allowing ion sensing at potentially greater distances. Using a remotely located passively gated single ion Geiger mode avalanche diode (SIGMA) detector we have demonstrated 100% detection efficiency at a distance of >75 μm from the center of the collecting junction. This detection efficiency is achieved with sensitivity to ∼600 or fewer electron-hole pairs produced by the implanted ion. Ion detectors with this sensitivity and integrated with a thin dielectric, for example a 5 nm gate oxide, using low energy Sb implantation would have an end of range straggle of -1 and 10 -4 for operation temperatures of ∼300 K and ∼77 K, respectively. Low temperature operation and reduced false, 'dark', counts are critical to achieving high confidence in single ion arrival. For the device performance in this work, the confidence is calculated as a probability of >98% for counting one and only one ion for a false count probability of 10 -4 at an average ion number per gated window of 0.015.

  11. Generation of Suprathermal Electrons by Collective Processes in Collisional Plasma

    Science.gov (United States)

    Tigik, S. F.; Ziebell, L. F.; Yoon, P. H.

    2017-11-01

    The ubiquity of high-energy tails in the charged particle velocity distribution functions (VDFs) observed in space plasmas suggests the existence of an underlying process responsible for taking a fraction of the charged particle population out of thermal equilibrium and redistributing it to suprathermal velocity and energy ranges. The present Letter focuses on a new and fundamental physical explanation for the origin of suprathermal electron velocity distribution function (EVDF) in a collisional plasma. This process involves a newly discovered electrostatic bremsstrahlung (EB) emission that is effective in a plasma in which binary collisions are present. The steady-state EVDF dictated by such a process corresponds to a Maxwellian core plus a quasi-inverse power-law tail, which is a feature commonly observed in many space plasma environments. In order to demonstrate this, the system of self-consistent particle- and wave-kinetic equations are numerically solved with an initially Maxwellian EVDF and Langmuir wave spectral intensity, which is a state that does not reflect the presence of EB process, and hence not in force balance. The EB term subsequently drives the system to a new force-balanced steady state. After a long integration period it is demonstrated that the initial Langmuir fluctuation spectrum is modified, which in turn distorts the initial Maxwellian EVDF into a VDF that resembles the said core-suprathermal VDF. Such a mechanism may thus be operative at the coronal source region, which is characterized by high collisionality.

  12. Detectors for relativistic heavy-ion experiments

    International Nuclear Information System (INIS)

    Braun-Munzinger, P.; Cleland, W.; Young, G.R.

    1989-04-01

    We present in some detail an overview of the detectors currently used in relativistic heavy-ion research at the BNL AGS and the CERN SPS. Following that, a detailed list of RandD projects is given, including specific areas of work which need to be addressed in preparation for further experiments at the AGS and SPS for the upcoming experiments at RHIC

  13. Silicon carbide detectors for diagnostics of ion emission from laser plasmas

    International Nuclear Information System (INIS)

    Musumeci, Paolo; Zimbone, Massimo; Calcagno, Lucia; Cutroneo, Maria; Torrisi, Lorenzo; Velyhan, Andry

    2014-01-01

    Silicon carbide (SiC) detectors have been employed to analyze the multi-MeV ions generated from laser plasma. The irradiation was performed with the iodine laser of Prague Asterix Laser System Laboratory operating at 10 16  W cm −2 pulse intensity. Thin metallic and polymeric targets were irradiated and the produced plasmas were monitored in the forward direction. The use of SiC detectors ensures the cutting of the visible and soft UV radiation emitted from plasma, enhancing the sensitivity to protons and very fast heavy ions. The time-of-flight spectra obtained by irradiating polymeric films with high laser pulse energy produce protons with energy in the range 1.0–2.5 MeV and all the charge states of carbon ions. The metallic Al target allows achieving energy up to 3.0 MeV for protons and 40 MeV for Al ions. All the results reveal the high performances of these detectors in terms of resolution and response time. (paper)

  14. Plasma effects for heavy ions in implanted silicon detectors

    International Nuclear Information System (INIS)

    Aiello, S.; Anzalone, A.; Campisi, M.G.; Cardella, G.; Cavallaro, Sl.; Filippo, E. De; Geraci, E.; Geraci, M.; Guazzoni, P.; Manno, M.C. Iacono; Lanzalone, G.; Lanzano, G.; Nigro, S. Lo; Pagano, A.; Papa, M.; Pirrone, S.; Politi, G.; Porto, F.; Rizzo, F.; Sambataro, S.; Sperduto, M.L.; Sutera, C.; Zetta, L.

    1999-01-01

    Plasma effects for heavy ions in implanted silicon detectors have been investigated for different detector characteristics as a function of type and energy of the detected particles. A new approach is presented and used to reproduce the effect of the plasma delay in the timing performances. The results are in good agreement with the present data and with previous measurements found in the literature

  15. Dosimetry in heavy ion beams using various detectors

    Czech Academy of Sciences Publication Activity Database

    Brabcová, Kateřina; Jadrníčková, Iva; Molokanov, A. G.; Spurný, František

    2010-01-01

    Roč. 45, č. 10 (2010), s. 1384-1386 ISSN 1350-4487. [Neutron and Ion Dosimetry Symposium /11./. Cape Town, 12.10.2009-16.10.2009] R&D Projects: GA ČR GA205/09/0171; GA AV ČR IAA100480902 Institutional research plan: CEZ:AV0Z10480505 Keywords : tack-etched detectors * LET spectra * TLD * heavy ion beams Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.019, year: 2010

  16. An ionization-chamber type of focal-plane detector for heavy ions

    International Nuclear Information System (INIS)

    Erskine, J.R.; Braid, T.H.; Stolfzfus, J.C.

    1976-01-01

    A focal-plane detector for heavy ions is described in which energy loss and total energy are measured with a gridded ionization chamber, and position along the focal plane and angle of incidence are measured with two resistive-wire proportional counters. The clean geometry of the detector makes it especially attractive for use with heavy ions of high specific ionization. Typical position resolutions of 1.0-1.5mm (fwhm) were observed over a 50 cm length of the detector in the focal plane of a split-pole magnetic spectrograph. Special tests were made which suggest that the limiting position resolution is 0.76 mm or better. The resolution of the energy-loss signal was typically 4.5% (fwhm). The resolution of the total energy signal was 1.0-1.5% (fwhm) for small entrance apertures of the spectrograph, although 0.7% resolution was observed under special circumstances. The angle of incidence was measured with an uncertainty of about 1.2% (fwhm). The availability of the many parameters needed for particle identification makes this detector especially useful for the study of weak reaction channels in heavy-ion-induced reactions. (Auth.)

  17. Suprathermal electron studies in the TCV tokamak: Design of a tomographic hard-x-ray spectrometer

    International Nuclear Information System (INIS)

    Gnesin, S.; Coda, S.; Decker, J.; Peysson, Y.

    2008-01-01

    Electron cyclotron resonance heating and electron cyclotron current drive, disruptive events, and sawtooth activity are all known to produce suprathermal electrons in fusion devices, motivating increasingly detailed studies of the generation and dynamics of this suprathermal population. Measurements have been performed in the past years in the tokamak a configuration variable (TCV) tokamak using a single pinhole hard-x-ray (HXR) camera and electron-cyclotron-emission radiometers, leading, in particular, to the identification of the crucial role of spatial transport in the physics of ECCD. The observation of a poloidal asymmetry in the emitted suprathermal bremsstrahlung radiation motivates the design of a proposed new tomographic HXR spectrometer reported in this paper. The design, which is based on a compact modified Soller collimator concept, is being aided by simulations of tomographic reconstruction. Quantitative criteria have been developed to optimize the design for the greatly variable shapes and positions of TCV plasmas.

  18. Beam profile measurement with CR-39 track detector for low-energy ions

    CERN Document Server

    Sato, F; Tanaka, T; Iida, T; Yamauchi, T; Oda, K

    1999-01-01

    A CR-39 track detector was successfully used to measure the outline of thin low-energy ion beams. After the etching, the surface of the detector was examined with an observation system composed of a Normarski microscope, a CCD camera and a digital image processing computer. Beam images obtained with the system were in good agreement on the outline of the beam formed with a beam aperture. Also, the resolving power in the beam outline measurement was roughly explained from the consideration of the ion range and the etch-pit growth in the chemical etching for the CR-39 detector.

  19. A gas ionisation Direct-STIM detector for MeV ion microscopy

    International Nuclear Information System (INIS)

    Norarat, Rattanaporn; Guibert, Edouard; Jeanneret, Patrick; Dellea, Mario; Jenni, Josef; Roux, Adrien; Stoppini, Luc; Whitlow, Harry J.

    2015-01-01

    Direct-Scanning Transmission Ion Microscopy (Direct-STIM) is a powerful technique that yields structural information in sub-cellular whole cell imaging. Usually, a Si p-i-n diode is used in Direct-STIM measurements as a detector. In order to overcome the detrimental effects of radiation damage which appears as a broadening in the energy resolution, we have developed a gas ionisation detector for use with a focused ion beam. The design is based on the ETH Frisch grid-less off-axis Geiger–Müller geometry. It is developed for use in a MeV ion microscope with a standard Oxford Microbeams triplet lens and scanning system. The design has a large available solid angle for other detectors (e.g. proton induced fluorescence). Here we report the performance for imaging ReNcells VM with μm resolution where energy resolutions of <24 keV fwhm could be achieved for 1 MeV protons using isobutane gas

  20. A silicon strip detector array for energy verification and quality assurance in heavy ion therapy.

    Science.gov (United States)

    Debrot, Emily; Newall, Matthew; Guatelli, Susanna; Petasecca, Marco; Matsufuji, Naruhiro; Rosenfeld, Anatoly B

    2018-02-01

    The measurement of depth dose profiles for range and energy verification of heavy ion beams is an important aspect of quality assurance procedures for heavy ion therapy facilities. The steep dose gradients in the Bragg peak region of these profiles require the use of detectors with high spatial resolution. The aim of this work is to characterize a one dimensional monolithic silicon detector array called the "serial Dose Magnifying Glass" (sDMG) as an independent ion beam energy and range verification system used for quality assurance conducted for ion beams used in heavy ion therapy. The sDMG detector consists of two linear arrays of 128 silicon sensitive volumes each with an effective size of 2mm × 50μm × 100μm fabricated on a p-type substrate at a pitch of 200 μm along a single axis of detection. The detector was characterized for beam energy and range verification by measuring the response of the detector when irradiated with a 290 MeV/u 12 C ion broad beam incident along the single axis of the detector embedded in a PMMA phantom. The energy of the 12 C ion beam incident on the detector and the residual energy of an ion beam incident on the phantom was determined from the measured Bragg peak position in the sDMG. Ad hoc Monte Carlo simulations of the experimental setup were also performed to give further insight into the detector response. The relative response profiles along the single axis measured with the sDMG detector were found to have good agreement between experiment and simulation with the position of the Bragg peak determined to fall within 0.2 mm or 1.1% of the range in the detector for the two cases. The energy of the beam incident on the detector was found to vary less than 1% between experiment and simulation. The beam energy incident on the phantom was determined to be (280.9 ± 0.8) MeV/u from the experimental and (280.9 ± 0.2) MeV/u from the simulated profiles. These values coincide with the expected energy of 281 MeV/u. The sDMG detector

  1. Calorimetric energy-dispersive detectors for ion beam analysis

    International Nuclear Information System (INIS)

    Andersen, H.H.

    1985-01-01

    Energy-dispersive detectors for photons and alpha particles have recently been built. They are based on designs for infrared bolometric detectors working at liquid helium temperatures. For 5.5 Mev alpha particles the energy resolution (FWHM) has been published to be better than 35 keV in preliminary experiments, but thermodynamic limits to the resolution were calculated to be of the order of a few tens of eV. In the present paper limitations to the resolution caused by fluctuations in the processes converting particle energy to heat in the detectors will be calculated. It appears that an FWHM of a few hundred eV for MeV alphas may realistically be hoped for. As these detectors are windowless and may at the same time extend solid angles as large as surface-barrier detectors, be built in any desired geometrical shape, and work with count rates well above 10 3 Hz, exiting possibilities for ion beam analysis will open up through their realization. (orig.)

  2. COROTATING INTERACTION REGION ASSOCIATED SUPRATHERMAL HELIUM ION ENHANCEMENTS AT 1 AU: EVIDENCE FOR LOCAL ACCELERATION AT THE COMPRESSION REGION TRAILING EDGE

    International Nuclear Information System (INIS)

    Ebert, R. W.; Dayeh, M. A.; Desai, M. I.; Mason, G. M.

    2012-01-01

    We examined the temporal profiles and peak intensities for 73 corotating interaction region (CIR)-associated suprathermal (∼0.1-8 MeV nucleon –1 ) helium (He) ion enhancements identified at STEREO-A, STEREO-B, and/or Advanced Composition Explorer between 2007 and 2010. We found that in most events the peak He intensity times were well organized by the CIR compression region trailing edge, regardless of whether or not a reverse shock was present. Out of these events, 19% had their 0.193 MeV nucleon –1 He intensities peak within 1 hr and 50% within 4.75 hr of the CIR trailing edge, the distribution having a 1σ value of 7.3 hr. Events with a 0.193 MeV nucleon –1 He intensity peak time within 1σ of the CIR trailing edge showed a positive correlation between the ∼0.1 and 0.8 MeV nucleon –1 He peak intensities and magnetic compression ratios in events both with and without a reverse shock. The peak intensities in all other events showed little to moderate correlation between these parameters. Our results provide evidence that some fraction of the CIR-associated –1 He intensity enhancements observed at 1 AU are locally driven. We suggest an extended source for the CIR-associated energetic particles observed at 1 AU where the –1 ions are accelerated locally at or near the CIR trailing edge, the intensities being proportional to the local compression ratio strength, while the >MeV particles are likely accelerated at CIR-driven shocks beyond Earth orbit.

  3. The heavy-ion physics programme with the ATLAS detector

    International Nuclear Information System (INIS)

    Rosselet, L

    2008-01-01

    The CERN LHC will collide lead ions at s√ = 5.5 TeV per nucleon pair and will provide crucial information about the formation of a quark-gluon plasma at the highest temperatures and densities ever created in the laboratory. We report on an updated evaluation of the ATLAS potential to study heavy-ion physics. The ATLAS detector will perform especially well for high pT phenomena even in the presence of the high-multiplicity soft background expected from lead-lead collisions, and most of the detector subsystems retain their nearly full capability. ATLAS will study a full range of observables which characterize the hot and dense medium formed in heavy-ion collisions. In addition to global measurements such as particle multiplicities and collective flow, heavy-quarkonia suppression, jet quenching and the modification of jets passing in the dense medium will be accessible. ATLAS will also study forward physics and ultraperipheral collisions using Zero Degree Calorimeters

  4. Segmented focal plane detector for light and heavy ions

    International Nuclear Information System (INIS)

    Wolfs, F.L.H.; Bryan, D.C.; Kurz, K.L.; Herrick, D.M.; Perera, P.A.A.; White, C.A.

    1992-01-01

    A segmented focal plane detector for an Enge split-pole spectrograph has been developed for the study of breakup reactions at very low relative energies. It consists of a 61 cm long segmented position-sensitive parallel plate avalanche counter backed by a large Bragg curve detector. A segmented plastic scintillator is mounted behind the anode of the Bragg curve detector and is used for particle identification of low-ionizing particles. The dead space between the two sections of the focal plane detector is 2.5 mm. The intrinsic position resolution of the detector is 1 mm. The intrinsic energy resolution depends on the energy of the incident ion and can be as good as 0.55%. The nuclear charge and mass resolutions are 0.3 e and 0.3 u, respectively. (orig.)

  5. Energization of helium ions by proton-induced hydromagnetic waves

    International Nuclear Information System (INIS)

    Gendrin, R.; Roux, A.

    1980-01-01

    We consider the diffusion of He + ions under the influence of ion cyclotron waves generated in a plasma consisting of three different ion populations: a thermal isotropic population containing both H + and He + ions and an energetic H + population, with a positive anisotropy A=T/sub perpendicular//T/sub parallel/-1. We compute, in the velocity space upsilon/sub parallel/, upsilon/sub perpendicular/, the diffusion curves that He + ions will follow in the presence of ion cyclotron waves propagating in such a medium. We show that for small concentrations of the He + ions, of the order of 1 to approx.10%, these ions can be energized by such a process up to and above suprathermal energies (E> or approx. =20 eV). On some occasions the He + ions may even reach energies of the order of the Alfven energy of the cold plasma population: E/sub a/approx. =m/sub p/V/sub a/ 2 approx. =5 keV. Characteristic diffusion times, in pitch angle and energy, for both ion species, are evaluated. They are of the order of 2 to 20 min. These theoretical results are discussed in the frame of recent observations by Geos experimenters showing the close association that exists between the occurrence of ion cyclotron ULF waves and the presence of thermal or supra-thermal He + ions in the equatorial region of the magnetosphere

  6. Fabrication and characterization of a 3D Positive ion detector and its applications

    Science.gov (United States)

    Venkatraman, Pitchaikannu; Sureka, Chandrasekaran Senbagavadivoo

    2017-11-01

    There is a growing interest to experimentally evaluate the track structure induced by ionizing particles in order to characterize the radiobiological quality of ionizing radiation for applications in radiotherapy and radiation protection. To do so, a novel positive ion detector based on the multilayer printed circuit board (PCB) technology has been proposed previously, which works under the principle of ion induced impact ionization. Based on this, an upgraded 3D positive ion detector was fabricated in order to improve its efficiency and use it for various applications. To improve the efficiency of the detector, cathodes with different insulators (Bakelite plate and Steatite Ceramics) and conducting layers (ITO, FTO, and Gold coated cathode) were studied under various gaseous media (methane, nitrogen, and air) using Am-241, Co-60, Co-57, Na-22, Cs-137, and Ba-133 sources. From this study, it is confirmed that the novel 3D positive ion detector that has been upgraded using gold as strip material, tungsten (87%) coated copper (13%) as the core wire, gold coated ceramic as cathode, and thickness of 3.483 mm showed 9.2% efficiency under methane medium at 0.9 Torr pressure using an Am-241 source. It is also confirmed that when the conductivity of the cathode and thickness of the detector is increased, the performance of the detector is improved significantly. Further, the scope of the detector to use in the field of radiation protection, radiation dosimetry, gamma spectrometry, radiation biology, and oncology are reported here.

  7. Heavy-ion irradiation effects on passivated implanted planar silicon detectors

    International Nuclear Information System (INIS)

    Coster, W. de; Brijs, B.; Vandervorst, W.; Burger, P.

    1992-01-01

    Commercially available p + nn + passivated implanted planar silicon detectors have been shown to be very performing for standard RBS-analysis with 4 He beams. Lifetimes are found to range up till >10 9 particles. The end of lifetime occurs concurrent with internal breakdown of the detector. Inverted n + np + detectors where the junction is located well outside the damage region, are expected to be less sensitive to the radiation damage and to have a higher lifetime. In the present paper the characteristics for heavy-ion detection of both types of detector are investigated and discussed upon. (orig.)

  8. Numerical Investigation on Electron and Ion Transmission of GEM-based Detectors

    Directory of Open Access Journals (Sweden)

    Bhattacharya Purba

    2018-01-01

    Full Text Available ALICE at the LHC is planning a major upgrade of its detector systems, including the TPC, to cope with an increase of the LHC luminosity after 2018. Different R&D activities are currently concentrated on the adoption of the Gas Electron Multiplier (GEM as the gas amplification stage of the ALICE-TPC upgrade version. The major challenge is to have low ion feedback in the drift volume as well as to ensure a collection of good percentage of primary electrons in the signal generation process. In the present work, Garfield simulation framework has been adopted to numerically estimate the electron transparency and ion backflow fraction of GEM-based detectors. In this process, extensive simulations have been carried out to enrich our understanding of the complex physical processes occurring within single, triple and quadruple GEM detectors. A detailed study has been performed to observe the effect of detector geometry, field configuration and magnetic field on the above mentioned characteristics.

  9. Numerical Investigation on Electron and Ion Transmission of GEM-based Detectors

    Science.gov (United States)

    Bhattacharya, Purba; Sahoo, Sumanya Sekhar; Biswas, Saikat; Mohanty, Bedangadas; Majumdar, Nayana; Mukhopadhyay, Supratik

    2018-02-01

    ALICE at the LHC is planning a major upgrade of its detector systems, including the TPC, to cope with an increase of the LHC luminosity after 2018. Different R&D activities are currently concentrated on the adoption of the Gas Electron Multiplier (GEM) as the gas amplification stage of the ALICE-TPC upgrade version. The major challenge is to have low ion feedback in the drift volume as well as to ensure a collection of good percentage of primary electrons in the signal generation process. In the present work, Garfield simulation framework has been adopted to numerically estimate the electron transparency and ion backflow fraction of GEM-based detectors. In this process, extensive simulations have been carried out to enrich our understanding of the complex physical processes occurring within single, triple and quadruple GEM detectors. A detailed study has been performed to observe the effect of detector geometry, field configuration and magnetic field on the above mentioned characteristics.

  10. Pulse-height response of silicon surface-barrier detectors to high-energy heavy ions

    International Nuclear Information System (INIS)

    Smith, G.D.

    1973-01-01

    The pulse-height defect (PHD) of high-energy heavy ions in silicon surface-barrier detectors can be divided into three components: (1) energy loss in the gold-surface layer, (2) a nuclear-stopping defect, and (3) a defect due to recombination of electron-hole pairs in the plasma created by the heavy ion. The plasma recombination portion of the PHD was the subject of this study using the variation of the PHD with (1) the angle of incidence of incoming heavy ions, and (2) changes in the detector bias. The Tandem Van de Graaff accelerator at Argonne National Laboratory was used to produce scattered beam ions ( 32 S, 35 Cl) and heavy target recoils (Ni, Cu, 98 Mo, Ag, Au) at sufficient energies to produce a significant recombination defect. The results confirm the existence of a recombination zone at the front surface of these detectors and the significance of plasma recombination as a portion of the pulse-height defect. (Diss. Abstr. Int., B)

  11. Detection of nitro-based and peroxide-based explosives by fast polarity-switchable ion mobility spectrometer with ion focusing in vicinity of Faraday detector.

    Science.gov (United States)

    Zhou, Qinghua; Peng, Liying; Jiang, Dandan; Wang, Xin; Wang, Haiyan; Li, Haiyang

    2015-05-29

    Ion mobility spectrometer (IMS) has been widely deployed for on-site detection of explosives. The common nitro-based explosives are usually detected by negative IMS while the emerging peroxide-based explosives are better detected by positive IMS. In this study, a fast polarity-switchable IMS was constructed to detect these two explosive species in a single measurement. As the large traditional Faraday detector would cause a trailing reactant ion peak (RIP), a Faraday detector with ion focusing in vicinity was developed by reducing the detector radius to 3.3 mm and increasing the voltage difference between aperture grid and its front guard ring to 591 V, which could remove trailing peaks from RIP without loss of signal intensity. This fast polarity-switchable IMS with ion focusing in vicinity of Faraday detector was employed to detect a mixture of 10 ng 2,4,6-trinitrotoluene (TNT) and 50 ng hexamethylene triperoxide diamine (HMTD) by polarity-switching, and the result suggested that [TNT-H](-) and [HMTD+H](+) could be detected in a single measurement. Furthermore, the removal of trailing peaks from RIP by the Faraday detector with ion focusing in vicinity also promised the accurate identification of KClO4, KNO3 and S in common inorganic explosives, whose product ion peaks were fairly adjacent to RIP.

  12. Suprathermal electron loss cone distributions in the solar wind: Ulysses observations

    International Nuclear Information System (INIS)

    Phillips, J. L.; Feldman, W. C.; Gosling, J. T.; Hammond, C. M.; Forsyth, R. J.

    1996-01-01

    We present observations by the Ulysses solar wind plasma experiment of a new class of suprathermal electron signatures. At low solar latitudes and heliocentric distances beyond 3.37 AU Ulysses encountered seven intervals, ranging in duration from 1 hour to 22 hours, in which the suprathermal distributions included an antisunward field-aligned beam and a return population with a flux dropout typically spanning ±60 deg. from the sunward field-aligned direction. All events occurred between the forward and reverse shocks or waves bounding corotating interaction regions (CIRs). The observations support a scenario in which the sunward-moving electrons result from reflection of the prevailing antisunward field-aligned beam at magnetic field compressions downstream from the spacecraft, with wide loss cones caused by the relatively weak mirror ratio. This hypothesis requires that the field magnitude within the CIRs actually increased locally with increasing field-aligned distance from the Sun

  13. Considerations for application of Si(Li) detectors in analyses of sub-keV, ion-induced x rays

    International Nuclear Information System (INIS)

    Musket, R.G.

    1985-01-01

    Spectroscopy of ion-induced x rays is commonly performed using lithium-drifted, silicon detectors, Si(Li), with beryllium windows. Strong absorption of x rays with energies below 1 keV occurs in even the thinnest commercially available beryllium windows and precludes useful analysis of sub-keV x rays. Access to the sub-keV x ray region can be achieved using windowless (WL) and ultra-thin-windowed (UTW) Si(Li) detectors. These detectors have been shown to be useful for spectroscopy of x rays with energies above approximately 200 eV. The properties of such detectors are reviewed with regard to analysis of ion-induced x rays. In particular, considerations of detection efficiency, output linearity, energy resolution, peak shapes, and vacuum requirements are presented. The use of ion excitation for determination of many detector properties serves to demonstrate the usefulness of WL and UTW detectors for the spectroscopy of sub-keV, ion-induced x rays. 23 refs., 4 figs

  14. 3D simulation of electron and ion transmission of GEM-based detectors

    Science.gov (United States)

    Bhattacharya, Purba; Mohanty, Bedangadas; Mukhopadhyay, Supratik; Majumdar, Nayana; da Luz, Hugo Natal

    2017-10-01

    Time Projection Chamber (TPC) has been chosen as the main tracking system in several high-flux and high repetition rate experiments. These include on-going experiments such as ALICE and future experiments such as PANDA at FAIR and ILC. Different R&D activities were carried out on the adoption of Gas Electron Multiplier (GEM) as the gas amplification stage of the ALICE-TPC upgrade version. The requirement of low ion feedback has been established through these activities. Low ion feedback minimizes distortions due to space charge and maintains the necessary values of detector gain and energy resolution. In the present work, Garfield simulation framework has been used to study the related physical processes occurring within single, triple and quadruple GEM detectors. Ion backflow and electron transmission of quadruple GEMs, made up of foils with different hole pitch under different electromagnetic field configurations (the projected solutions for the ALICE TPC) have been studied. Finally a new triple GEM detector configuration with low ion backflow fraction and good electron transmission properties has been proposed as a simpler GEM-based alternative suitable for TPCs for future collider experiments.

  15. Heavy Ion Physics Prospects with the ATLAS Detector at the LHC

    CERN Document Server

    Grau, N

    2008-01-01

    The next great energy frontier in Relativistic Heavy Ion Collisions is quickly approaching with the completion of the Large Hadron Collider and the ATLAS experiment is poised to make important contributions in understanding QCD matter at extreme conditions. While designed for high-pT measurements in high-energy p+p collisions, the detector is well suited to study many aspects of heavy ion collisions from bulk phenomena to high-pT and heavy flavor physics. With its large and finely segmented electromagnetic and hadronic calorimeters, the ATLAS detector excels in measurements of photons and jets, observables of great interest at the LHC. In this talk, we highlight the performance of the ATLAS detector for Pb+Pb collisions at the LHC with special emphasis on a key feature of the ATLAS physics program: jet and direct photon measurements.

  16. Charge collection characteristics of a super-thin diamond membrane detector measured with high-energy heavy ions

    International Nuclear Information System (INIS)

    Iwamoto, N.; Makino, T.; Onoda, S.; Ohshima, T.; Kamiya, T.; Kada, W.; Skukan, N.; Grilj, V.; Jaksic, M.; Pomorski, M.

    2014-01-01

    A transmission particle detector based on a super-thin diamond membrane film which can also be used simultaneously as a vacuum window for ion beam extraction has been developed. Charge collection characteristics of a μ-thick diamond membrane detector for high-energy heavy ions including 75 MeV Ne, 150 MeV Ar, 322 MeV Kr, and 454 MeV Xe have been investigated for the first time. Charge collection signals under single particle flux from the thin part are stable and are well distinguishable from background signals. This behavior suggests that the diamond membrane detector could be used for counting single ions. On the other hand, charge collection efficiency is found to decrease with increasing of charge generated in the diamond membrane detector. This suggests that the pulse height defect, which has been previously reported for Si and SiC detectors, also occurs in the diamond membrane detector. (authors)

  17. Ion beam evaluation of silicon carbide membrane structures intended for particle detectors

    Energy Technology Data Exchange (ETDEWEB)

    Pallon, J., E-mail: jan.pallon@nuclear.lu.se [Division of Nuclear Physics, Physics Department, Lund University, Box 118, SE-221 00 Lund (Sweden); Syväjärvi, M. [Linköping University, Department of Physics, Chemistry and Biology, SE-58183 Linköping (Sweden); Graphensic AB, Teknikringen 1F, SE-58330 Linköping (Sweden); Wang, Q. [Sensor System, ACREO Swedish ICT AB, Box 1070, SE-164 25 Kista (Sweden); Yakimova, R.; Iakimov, T. [Linköping University, Department of Physics, Chemistry and Biology, SE-58183 Linköping (Sweden); Graphensic AB, Teknikringen 1F, SE-58330 Linköping (Sweden); Elfman, M.; Kristiansson, P.; Nilsson, E.J.C.; Ros, L. [Division of Nuclear Physics, Physics Department, Lund University, Box 118, SE-221 00 Lund (Sweden)

    2016-03-15

    Thin ion transmission detectors can be used as a part of a telescope detector for mass and energy identification but also as a pre-cell detector in a microbeam system for studies of biological effects from single ion hits on individual living cells. We investigated a structure of graphene on silicon carbide (SiC) with the purpose to explore a thin transmission detector with a very low noise level and having mechanical strength to act as a vacuum window. In order to reach very deep cavities in the SiC wafers for the preparation of the membrane in the detector, we have studied the Inductive Coupled Plasma technique to etch deep circular cavities in 325 μm prototype samples. By a special high temperature process the outermost layers of the etched SiC wafers were converted into a highly conductive graphitic layer. The produced cavities were characterized by electron microscopy, optical microscopy and proton energy loss measurements. The average membrane thickness was found to be less than 40 μm, however, with a slightly curved profile. Small spots representing much thinner membrane were also observed and might have an origin in crystal defects or impurities. Proton energy loss measurement (also called Scanning Transmission Ion Microscopy, STIM) is a well suited technique for this thickness range. This work presents the first steps of fabricating a membrane structure of SiC and graphene which may be an attractive approach as a detector due to the combined properties of SiC and graphene in a monolithic materials structure.

  18. Status of the Instrument Control Unit for EPD on-board Solar Orbiter

    Science.gov (United States)

    Sánchez Prieto, Sebastián; Da Silva, Antonio; Rodriguez Polo, Oscar; Parra Espada, Pablo; Gutierrez Molina, Oscar; Fernandez Salgado, Javier

    Solar Orbiter is the next heliospheric mission sponsored by ESA. The launch is planned for 2017 and it will be as close as 0.28 AU from the Sun. One of the instruments for Solar Orbiter is the Energetic Particle Detector (EPD) responsible for measuring energies from 2 keV to 200 MeV/n. EPD consists of four detectors, Electron Proton Telescope (EPT), High Energy Telescope (HET), SupraThermal Electrons, Ions, & Neutrals (STEIN), and Suprathermal Ion Spectrograph (SIS), plus the Instrument Control Unit called ICU. The Space Research Group of the University of Alcalá in Spain is the responsible for developing the ICU. In this work we present the development status of the ICU after the Critical Design Review. We also address the planned activities for the next year including the development of the Engineering and Qualification Model (EQM) and Flight Model (PM). Special focus is paid to the software and verification & validation activities.

  19. Fourth workshop on experiments and detectors for a relativistic heavy ion collider

    International Nuclear Information System (INIS)

    Fatyga, M.; Moskowitz, B.

    1990-01-01

    This report contains papers on the following topics: physics at RHIC; flavor flow from quark-gluon plasma; space-time quark-gluon cascade; jets in relativistic heavy ion collisions; parton distributions in hard nuclear collisions; experimental working groups, two-arm electron/photon spectrometer collaboration; total and elastic pp cross sections; a 4π tracking TPC magnetic spectrometer; hadron spectroscopy; efficiency and background simulations for J/ψ detection in the RHIC dimuon experiment; the collision regions beam crossing geometries; Monte Carlo simulations of interactions and detectors; proton-nucleus interactions; the physics of strong electromagnetic fields in collisions of relativistic heavy ions; a real time expert system for experimental high energy/nuclear physics; the development of silicon multiplicity detectors; a pad readout detector for CRID/tracking; RHIC TPC R ampersand D progress and goals; development of analog memories for RHIC detector front-end electronic systems; calorimeter/absorber optimization for a RHIC dimuon experiment; construction of a highly segmented high resolution TOF system; progress report on a fast, particle-identifying trigger based on ring-imaging and highly integrated electronics for a TPC detector

  20. Fourth workshop on experiments and detectors for a relativistic heavy ion collider

    Energy Technology Data Exchange (ETDEWEB)

    Fatyga, M.; Moskowitz, B. (eds.)

    1990-01-01

    This report contains papers on the following topics: physics at RHIC; flavor flow from quark-gluon plasma; space-time quark-gluon cascade; jets in relativistic heavy ion collisions; parton distributions in hard nuclear collisions; experimental working groups, two-arm electron/photon spectrometer collaboration; total and elastic pp cross sections; a 4{pi} tracking TPC magnetic spectrometer; hadron spectroscopy; efficiency and background simulations for J/{psi} detection in the RHIC dimuon experiment; the collision regions beam crossing geometries; Monte Carlo simulations of interactions and detectors; proton-nucleus interactions; the physics of strong electromagnetic fields in collisions of relativistic heavy ions; a real time expert system for experimental high energy/nuclear physics; the development of silicon multiplicity detectors; a pad readout detector for CRID/tracking; RHIC TPC R D progress and goals; development of analog memories for RHIC detector front-end electronic systems; calorimeter/absorber optimization for a RHIC dimuon experiment; construction of a highly segmented high resolution TOF system; progress report on a fast, particle-identifying trigger based on ring-imaging and highly integrated electronics for a TPC detector.

  1. Recent results from CVD-diamond heavy-ion detectors

    International Nuclear Information System (INIS)

    Berdermann, E.; Fischer, B.E.; Schloegl, M.; Stelzer, H.; Voss, B.

    2000-03-01

    Latest results from radiation hardness measurements as well as single-particle pulse shape parameters, pulse-height distributions and time spectra are presented. An intrinsic time resolution of 29 ps is achieved with 52 Cr ions of 650 MeV/amu and of 53 ps with 12 C ions of 1.5 Gev/amu, respectively. The resolution is by 20% worse when increasing the beam intensity from 10 6 ions/s to 10 8 ions/s. Performing 58 Ni fragmentation, collected charge distributions are measured in the range 15 241 Am-α-distributions increasing the electric field applied to the detector. In order to visualize and to quantify the influence of the electric field as well as of the total particle fluence to the charge-collection efficiency micro-beam measurements are performed with 12 C ions of 5.9 MeV/amu stopped in the diamond bulk. Pulse-height spectra and charge-collection maps under different conditions are discussed. (orig.)

  2. Current signal of silicon detectors facing charged particles and heavy ions

    International Nuclear Information System (INIS)

    Hamrita, H.

    2005-07-01

    This work consisted in collecting and studying for the first time the shapes of current signals obtained from charged particles or heavy ions produced by silicon detectors. The document is divided into two main parts. The first consisted in reducing the experimental data obtained with charged particles as well as with heavy ions. These experiments were performed at the Orsay Tandem and at GANIL using LISE. These two experiments enabled us to create a data base formed of current signals with various shapes and various times of collection. The second part consisted in carrying out a simulation of the current signals obtained from the various ions. To obtain this simulation we propose a new model describing the formation of the signal. We used the data base of the signals obtained in experiments in order to constrain the three parameters of our model. In this model, the charge carriers created are regarded as dipoles and their density is related to the dielectric polarization in the silicon detector. This phenomenon induces an increase in permittivity throughout the range of the incident ion and consequently the electric field between the electrodes of the detector is decreased inside the trace. We coupled with this phenomenon a dissociation and extraction mode of the charge carriers so that they can be moved in the electric field. (author)

  3. A Supra-Thermal Energetic Particle detector (STEP) for composition measurements in the range approximately 20 keV/nucleon to 1 MeV/nucleon

    Science.gov (United States)

    Mason, G. M.; Gloeckler, G.

    1981-01-01

    A detector system is described, employing a time-of-flight versus residual energy technique which allows measurement of particle composition (H-Fe), energy spectral and anisotropies in an energy range unaccessible with previously flown sensors. Applications of this method to measurements of the solar wind ion composition are discussed.

  4. Heavy Ion Physics with the ATLAS Detector at the LHC

    International Nuclear Information System (INIS)

    Trzupek, A.

    2009-01-01

    The heavy-ion program at LHC will be pursued by three experiments including ATLAS, a multipurpose detector to study p + p collisions. A report on the potential of the ATLAS detector to uncover new physics in Pb + Pb collisions at energies thirty times larger than energy available at RHIC will be presented. Key aspects of the heavy-ion program of the ATLAS experiment, implied by measurements at RHIC, will be discussed. They include measurement capability of high-p T hadronic and electromagnetic probes, quarkonia as well as elliptic flow and other bulk phenomena. Measurements by the ATLAS experiment will provide crucial information about the formation of a quark-gluon plasma at the new energy scale accessible at the LHC. (author)

  5. Improvement of the focal-plane detector system for medium heavy ions

    International Nuclear Information System (INIS)

    Wan Yude; Li Zhongzhen

    1992-01-01

    An improved medium heavy ion focal-plane detector system (500 mm long) was tested with beam and has been used in nuclear physics experiment. The measured results at tandem accelerator with 66 MeV 12 C beam are: the energy resolution of the residual energy E detector is about 7%. The experiment of particle discrimination has been performed

  6. Output characteristics of piezoelectric lead zirconate titanate detector using high-energy heavy-ion beam

    International Nuclear Information System (INIS)

    Takechi, Seiji; Sekiguchi, Masahiro; Miyachi, Takashi; Kobayashi, Masanori; Hattori, Maki; Okudaira, Osamu; Shibata, Hiromi; Fujii, Masayuki; Okada, Nagaya; Murakami, Takeshi; Uchihori, Yukio

    2014-01-01

    A radiation detector fabricated using piezoelectric lead zirconate titanate (PZT) has been studied by irradiating it with a 400 MeV/n xenon (Xe) beam. The beam diameter was controlled to change the irradiation conditions. It was found that the magnitude of the output observed from the PZT detector may be related to the number of Xe ions per unit area per unit time within the limits of the experimental conditions. -- Highlights: • The performance of PZT detector was studied by irradiation of a 400 MeV/n Xe beam. • The beam diameter was controlled to change the irradiation conditions. • By the control, the number of Xe ions per one pulse was changed from ∼500 to ∼1500. • The output of the PZT detector was not always larger with more intense beam. • The energy of Xe ions per unit area per unit time may determine the output

  7. Ion Feedback Suppression Using Inclined MCP Holes in a Single-MCP+Micromegas+Pads Detector

    International Nuclear Information System (INIS)

    Va'vra, J.; Sumiyoshi, T.

    2005-01-01

    We show that the ion backflow to photocathode can be completely suppressed if one uses inclined MCP holes in a presence of magnetic field. The inclined hole angles are chosen to be aligned with the Lorentz electron angle allowing the electron transmission and amplification, while positive ions, traveling along a different angle, are caught on the MCP hole walls. The detector under investigation is a new gaseous detector structure based on a tandem of two parts, a single MCP (Microchannel) plate, a Micromegas with pad readout. We are aiming to develop a gaseous photon detector with the Bialkali photocathode, however, one could use some ideas in the paper for other types of detectors

  8. Ion feedback suppression using inclined MCP holes in a 'single-MCP+micromegas+pads' detector

    International Nuclear Information System (INIS)

    Va'vra, J.; Sumiyoshi, T.

    2005-01-01

    We show that the ion backflow to photocathode can be completely suppressed if one uses inclined MCP holes in the presence of a magnetic field. The inclined hole angles are chosen to be aligned with the Lorentz electron angle allowing the electron transmission and amplification, while positive ions, traveling along a different angle, are caught on the MCP hole walls. The detector under investigation is a new gaseous detector structure based on a tandem of two parts, a single MCP (microchannel plate), a micromegas with pad readout. We are aiming to develop a gaseous photon detector with the Bialkali photocathode, however, one could use some ideas in the paper for other types of detectors

  9. Energetic ion loss detector on the Alcator C-Mod tokamak.

    Science.gov (United States)

    Pace, D C; Granetz, R S; Vieira, R; Bader, A; Bosco, J; Darrow, D S; Fiore, C; Irby, J; Parker, R R; Parkin, W; Reinke, M L; Terry, J L; Wolfe, S M; Wukitch, S J; Zweben, S J

    2012-07-01

    A scintillator-based energetic ion loss detector has been successfully commissioned on the Alcator C-Mod tokamak. This probe is located just below the outer midplane, where it captures ions of energies up to 2 MeV resulting from ion cyclotron resonance heating. After passing through a collimating aperture, ions impact different regions of the scintillator according to their gyroradius (energy) and pitch angle. The probe geometry and installation location are determined based on modeling of expected lost ions. The resulting probe is compact and resembles a standard plasma facing tile. Four separate fiber optic cables view different regions of the scintillator to provide phase space resolution. Evolving loss levels are measured during ion cyclotron resonance heating, including variation dependent upon individual antennae.

  10. Detector development for heavy-ions from 10 to 200 MeV/A

    International Nuclear Information System (INIS)

    Gruhn, C.R.

    1979-01-01

    Heavy Ion (HI) physics has evolved with a class of detector problems and needs peculiar to this young and growing field of physics. Large solid angles and good accomodation for events with high multiplicities are a prerequisite in a large number of HI experiments. Usually it is desired to measure with high precision the momentum, charge, and mass of the particles. The high charge (Z) of the particles emphasizes such problems as space charge, recombination, plasma clearing times, and radiation effects. A HI detector program in gaseous ion chambers at LBL is the subject of talk today. The talk is in three sections. The first is concerned with HI energy loss fluctuations. The remaining two secions discuss two detector alternatives considered: Bragg Curve Spectroscopy and Precision Relativistic DE/DX Measurements

  11. CHICO, a heavy ion detector for Gammasphere

    International Nuclear Information System (INIS)

    Simon, M.W.; Cline, D.; Wu, C.Y.; Gray, R.W.; Teng, R.; Long, C.

    2000-01-01

    A 4π position-sensitive heavy-ion detector system, CHICO, has been developed primarily for use in conjunction with the 4π γ-ray facility, Gammasphere. The CHICO detector comprises an array of 20 Parallel Plate Avalanche Counters (PPACs) covering 12 deg. <θ<85 deg. and 95 deg. <θ<168 deg. and 280 deg. in phi. The PPACs have segmented delay-line cathode boards, measuring the polar scattering angle θ to 1 deg., and segmented anodes, measuring the azimuthal angle phi with 9 deg. resolution, while measuring the time-of-flight difference with 500 ps resolution. For binary reactions the kinematics can be reconstructed from the measured information, allowing identification of the target- and projectile-like nuclei with a mass resolution of Δm/m∼5%. The measured masses, recoil velocities, and recoil angles allow correction for Doppler shift and assignment of individual γ-rays to decay of the correct reaction product. This paper describes the design, operation and performance of the CHICO detector. The powerful combination of CHICO plus Gammasphere provides new research opportunities for the study of nuclear structure and reactions

  12. MEGHNAD – A multi element detector array for heavy ion collision ...

    Indian Academy of Sciences (India)

    When heavy ion beam available from such machines fall on a target and undergo collision, very rich and often pristine fields of research open up. In order to carry on such activities, we have taken up a project to build a multi element gamma, heavy ion and neutron array of detectors (MEGHNAD) to detect and study the ...

  13. The heavy-ion physics programme with the ATLAS detector

    International Nuclear Information System (INIS)

    Pozdnyakov, V.N.; Vertogradova, Yu.L.

    2008-01-01

    The CERN LHC collider will operate with lead ions at √s of 5.5 TeV/nucleon. The ATLAS detector, designed to study high-p T physics in pp mode of the LHC, has potential to study ultrarelativistic heavy-ion collisions in a full range of observables characterizing the extremely dense matter and the formation of a quark-gluon plasma. The ATLAS physics programme includes global event measurements (particle multiplicities, transverse momentum), suppression of heavy-quarkonia production, jet quenching and study of ultraperipheral collisions

  14. CR-39 nuclear track detector application for the diagnostics of low energy high power ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Opekounov, M S; Pechenkin, S A; Remnev, G E [Nuclear Physics Institute, Tomsk (Russian Federation); Ivonin, I V [Siberian Physical-Technical Institute, Tomsk (Russian Federation)

    1997-12-31

    The results of investigation of the spectral composition of ion beams generated by the magneto-insulated ion diode of the MUK-M and TEMP accelerators. The energy and mass characteristics of the accelerated ion beam were determined by a Thomson spectrometer with a CR-39 plate detector (MOM - Atomki Nuclear Track Detector, Type MA-ND/p). The accelerated ion energy was from 40 to 240 keV. The ion current density range was from 1 to 10 A/cm{sup 2}. The mass composition contained hydrogen, nitrogen, carbon and aluminum ions. The individual track analysis showed the track form, depth and diameter in dependence on the ion mass and energy. (author). 2 figs., 5 refs.

  15. A supra-thermal energetic particle detector /STEP/ for composition measurements in the range of about 20 keV/nucleon to 1 MeV/nucleon

    Science.gov (United States)

    Mason, G. M.; Gloeckler, G.

    1981-01-01

    A novel detector system is described, employing a time-of-flight versus residual energy technique which allows measurement of particle composition (H-Fe), energy spectra and anisotropies in an energy range unaccessible with previously flown sensors. Applications of this method to measurements of the solar wind ion composition are also discussed.

  16. Dust-acoustic solitons in quantum plasma with kappa-distributed ions

    Indian Academy of Sciences (India)

    Abstract. Arbitrary amplitude dust-acoustic (DA) solitary waves in an unmagnetized and col- lisionless quantum dusty plasma comprising cold dust particles, kappa (κ)-distributed ions and degenerate electrons are investigated. The influence of suprathermality and quantum effects on the linear dispersion relation of DA ...

  17. Calorimetric low-temperature detectors on semiconductor base for the energy-resolving detection of heavy ions

    International Nuclear Information System (INIS)

    Kienlin, A. von.

    1994-01-01

    In the framework of this thesis for the first time calorimetric low-temperature detectors for the energy-resolving detection of heavy ions were developed and successfully applied. Constructed were two different detector types, which work both with a semiconductor thermistor. The temperature increasement effected by a particle incidence is read out. In the first detector type the thermistor was simutaneously used as absorber. The thickness of the germanium crystals was sufficient in order to stop the studied heavy ions completely. In the second type, a composed calorimeter, a sapphire crystal, which was glued on a germanium thermistor, served as absorber for the incident heavy ions. The working point of the calorimeter lies in the temperature range (1.2-4.2 K), which is reachable with a pumped 4 He cryostat. The temperatur increasement of the calorimeter amounts after the incidence of a single α particle about 20-30 μK and that after a heavy ion incidence up to some mK. An absolute energy resolution of 400-500 keV was reached. In nine beam times the calorimeters were irradiated by heavy ions ( 20 Ne, 40 Ar, 136 Xe, 208 Pb, 209 Bi) of different energies (3.6 MeV/nucleon< E<12.5 MeV/nucleon) elastically scattered from gold foils. In the pulse height spectra of the first detector type relatively broad, complex-structurated line shapes were observed. By systematic measurements dependences of the complex line structures on operational parameters of the detector, the detector temperature, and the position of the incident particle could be detected. Together with the results of further experiments a possible interpretation of these phenomena is presented. Contrarily to the complex line structures of the pure germanium thermistor the line shapes in the pulse height spectra, which were taken up in a composite germanium/sapphire calorimeter, are narrow and Gauss-shaped

  18. Effect of suprathermal electrons on the impurity ionization state

    International Nuclear Information System (INIS)

    Ochando, M A; Medina, F; Zurro, B; McCarthy, K J; Pedrosa, M A; Baciero, A; Rapisarda, D; Carmona, J M; Jimenez, D

    2006-01-01

    The effect of electron cyclotron resonance heating induced suprathermal electron tails on the ionization of iron impurities in magnetically confined plasmas is investigated. The behaviour of plasma emissivity immediately after injection provides evidence of a spatially localized 'shift' towards higher charge states of the impurity. Bearing in mind that the non-inductive plasma heating methods generate long lasting non-Maxwellian distribution functions, possible implications on the deduced impurity transport coefficients, when fast electrons are present, are discussed

  19. A focal plane detector for both light and heavy ions

    International Nuclear Information System (INIS)

    Ophel, T.R.; Johnston, A.

    1978-05-01

    The characteristics of a multi-element, ionization-type focal plane detector with an effective length of 53 cm have been evaluated for various ions ranging between protons and 32 S. The position resolution obtained is typically 1 mm. Excellent energy (0.49% for 16 O) and angular resolution (0.2 degrees with respect to beam direction for 7 Li) have been obtained enabling clean separation of ion species at essentially full angular acceptance of a split-pole spectrograph

  20. Heavy ion inelastic scattering with a 4π gamma detector

    International Nuclear Information System (INIS)

    Gross, E.E.

    1989-01-01

    Heavy-ion inelastic scattering with a new technique that uses a 4π γ-ray detector in coincidence with charged particle detectors is applied to 24 Mg(200 MeV) + 208 Pb scattering. In addition to differential cross sections, a complete particle-γ angular correlation is obtained for decay of the 2 1 + (1.37 MeV) state of 24 Mg. The data are analyzed in coupled-channels. The correlation data proves to be especially sensitive to the static quadrupole moment. 14 refs., 9 figs

  1. Ignition and burn propagation with suprathermal electron auxiliary heating

    International Nuclear Information System (INIS)

    Han Shensheng; Wu Yanqing

    2000-01-01

    The rapid development in ultrahigh-intensity lasers has allowed the exploration of applying an auxiliary heating technique in inertial confinement fusion (ICF) research. It is hoped that, compared with the 'standard fast ignition' scheme, raising the temperature of a hot-spot over the ignition threshold based on the shock-heated temperature will greatly reduce the required output energy of an ignition ultrahigh-intensity pulse. One of the key issues in ICF auxiliary heating is: how can we transport the exogenous energy efficiently into the hot-spot of compressed DT fuel? A scheme is proposed with three phases. First, a partial-spherical-shell capsule, such as double-conical target, is imploded as in the conventional approach to inertial fusion to assemble a high-density fuel configuration with a hot-spot of temperature lower than the ignition threshold. Second, a hole is bored through the shell outside the hot-spot by suprathermal electron explosion boring. Finally, the fuel is ignited by suprathermal electrons produced in the high-intensity ignition laser-plasma interactions. Calculations with a simple hybrid model show that the new scheme can possibly lead to ignition and burn propagation with a total drive energy of a few tens of kilojoules and an output energy as low as hundreds of joules for a single ignition ultrahigh-intensity pulse. (author)

  2. Study of the thermal and suprathermal electron density fluctuations of the plasma in the Focus experiment

    International Nuclear Information System (INIS)

    Jolas, A.

    1981-10-01

    An experiment on Thomson scattering of ruby laser light by the electrons of a plasma produced by an intense discharge between the electrodes of a coaxial gun in a gas at low pressure has been carried out. It is shown that the imploding plasma is made up of layers with different characteristics: a dense plasma layer where the density fluctuations are isotropic and have a thermal level, and a tenuous plasma layer where the fluctuations are anisotropic, and strongly suprathermal. The suprathermal fluctuations are attributed to microscopic instabilities generated by the electric current circulating in the transition zone where the magnetic field penetrates the plasma [fr

  3. Heavy Ion Physics with the ATLAS Detector

    CERN Document Server

    Nevski, P

    2006-01-01

    The ATLAS experiment at the LHC plans to study the bulk matter formed in heavy ion collisions, already being studied at RHIC, as well as crucial reference data from p+p and p+A collisions. ATLAS is designed to perform optimally at the nominal machine luminosity of 10^34 cm-2s-1. It has a finely segmented electromagnetic and hadronic calorimeters covering 10 units of rapidity, allowing the study of jets and fragmentation functions in detail in tandem with the inner tracking system. Preliminary studies also indicate that it will be possible to tag b-jets in the heavy ion environment. Upsilon and J/Psi can be reconstructed through the di-muon decay channel. There is also an important "day 1" program planned, that will use the data provided by both p+p and A+A collisions to study bulk features of the collision dynamics. We discuss the current status of simulation studies and plans of the heavy ion physics program with the ATLAS detector during the A+A and p+A runs.

  4. Heavy Ion Physics with the ATLAS Detector

    CERN Multimedia

    Takai, H

    2003-01-01

    I guess the first thing that comes to people's mind is why is an experiment such as ATLAS interested in heavy ion physics. What is heavy ion physics anyway? The term heavy ion physics refers to the study of collisions between large nuclei such as lead, atomic number 208. But why would someone collide something as large and extensive as lead nuclei? When two nuclei collide there is a unique opportunity to study QCD at extreme energy densities. This said why do we think ATLAS is a good detector to study this particular physics? Among many of the simultaneous collisions that takes place when two nuclei encouter, hard scattering takes place. The unique situation now is that before hadronization partons from hard scattering may feel the surrounding media serving as an ideal probe for the matter formed in these collisions. As a consequence of this, jets may be quenched and their properties, e.g. fragmentation function or cone radius, modified when compared to proton-proton collisions. This is precisely where ATL...

  5. Characteristics of solar and heliospheric ion populations observed near earth

    International Nuclear Information System (INIS)

    Gloeckler, G.

    1984-01-01

    The composition and spectra of ions in solar-energetic-particle and energetic-storm-particle events, of diffuse ions upstream of the earth bow shock, and of ions in deep-geomagnetic-tail plasmoids are characterized in a summary of in situ observations. Data are presented in graphs and tables, and remarkable similarities are noted in the distribution functions of the heliospheric ion populations. The solar wind, acting through acceleration mechanisms associated with shocks and turbulence, is identified as the major plasma source of suprathermal and energetic particles. 33 references

  6. CINEMA (Cubesat for Ion, Neutral, Electron, MAgnetic fields)

    Science.gov (United States)

    Lin, R. P.; Parks, G. K.; Halekas, J. S.; Larson, D. E.; Eastwood, J. P.; Wang, L.; Sample, J. G.; Horbury, T. S.; Roelof, E. C.; Lee, D.; Seon, J.; Hines, J.; Vo, H.; Tindall, C.; Ho, J.; Lee, J.; Kim, K.

    2009-12-01

    The NSF-funded CINEMA mission will provide cutting-edge magnetospheric science and critical space weather measurements, including high sensitivity mapping and high cadence movies of ring current, >4 keV Energetic Neutral Atom (ENA), as well as in situ measurements of suprathermal electrons (>~2 keV) and ions (>~ 4 keV) in the auroral and ring current precipitation regions, all with ~1 keV FWHM resolution and uniform response up to ~100 keV. A Suprathermal Electron, Ion, Neutral (STEIN) instrument adds an electrostatic deflection system to the STEREO STE (SupraThermal Electron) 4-pixel silicon semiconductor sensor to separate ions from electrons and from ENAs up to ~20 keV. In addition, inboard and outboard (on an extendable 1m boom) magnetoresistive sensor magnetometers will provide high cadence 3-axis magnetic field measurements. A new attitude control system (ACS) uses torque coils, a solar aspect sensor and the magnetometers to de-tumble the 3u CINEMA spacecraft, then spin it up to ~1 rpm with the spin axis perpendicular to the ecliptic, so STEIN can sweep across most of the sky every minute. Ideally, CINEMA will be placed into a high inclination low earth orbit that crosses the auroral zone and cusp. An S-band transmitter will be used to provide > ~8 kbps orbit-average data downlink to the ~11m diameter antenna of the Berkeley Ground Station. Two more identical CINEMA spacecraft will be built by Kyung Hee University (KHU) in Korea under their World Class University (WCU) program, to provide stereo ENA imaging and multi-point in situ measurements. Furthermore, CINEMA’s development of miniature particle and magnetic field sensors, and cubesat-size spinning spacecraft will be important for future nanosatellite space missions.

  7. Statistical analysis of suprathermal electron drivers at 67P/Churyumov-Gerasimenko

    Science.gov (United States)

    Broiles, Thomas W.; Burch, J. L.; Chae, K.; Clark, G.; Cravens, T. E.; Eriksson, A.; Fuselier, S. A.; Frahm, R. A.; Gasc, S.; Goldstein, R.; Henri, P.; Koenders, C.; Livadiotis, G.; Mandt, K. E.; Mokashi, P.; Nemeth, Z.; Odelstad, E.; Rubin, M.; Samara, M.

    2016-11-01

    We use observations from the Ion and Electron Sensor (IES) on board the Rosetta spacecraft to study the relationship between the cometary suprathermal electrons and the drivers that affect their density and temperature. We fit the IES electron observations with the summation of two kappa distributions, which we characterize as a dense and warm population (˜10 cm-3 and ˜16 eV) and a rarefied and hot population (˜0.01 cm-3 and ˜43 eV). The parameters of our fitting technique determine the populations' density, temperature, and invariant kappa index. We focus our analysis on the warm population to determine its origin by comparing the density and temperature with the neutral density and magnetic field strength. We find that the warm electron population is actually two separate sub-populations: electron distributions with temperatures above 8.6 eV and electron distributions with temperatures below 8.6 eV. The two sub-populations have different relationships between their density and temperature. Moreover, the two sub-populations are affected by different drivers. The hotter sub-population temperature is strongly correlated with neutral density, while the cooler sub-population is unaffected by neutral density and is only weakly correlated with magnetic field strength. We suggest that the population with temperatures above 8.6 eV is being heated by lower hybrid waves driven by counterstreaming solar wind protons and newly formed, cometary ions created in localized, dense neutral streams. To the best of our knowledge, this represents the first observations of cometary electrons heated through wave-particle interactions.

  8. Plasma rest frame distributions of suprathermal ions in the earth's foreshock region

    International Nuclear Information System (INIS)

    Sentman, D.D.; Kennel, C.F.; Frank, L.A.

    1981-01-01

    We present rest frame ion distributions computed from three-dimensional observations of upstream superthermal ions gained by the Universtiy of Iowa Quadrispherical Lepedea on ISEE-1. The observations are for a single inbound, midmorning pass starting upstream from the ion foreshock and continuing across the quasiparallel bow shock into the magnetosheath. The crossing of the ion foreshock boundary is marked by a several minute burst of ions of temperature 100--200 eV moving along the IMF away from the bow shock at 500 km/s relative to the solar wind. The observation of these 'reflected' ions is followed by an extended interval of 'diffuse' ions of temperatures 2--3 keV flowing at approx.250 km/s relative to the solar wind and persisting until the bow shock is crossed. The diffuse ion β has a value of approximately 6 in the region of the superthermal ions, exceeding the normal thermal β of the solar wind by roughly an order of magnitude. Both types of superthermal ions constitute roughly 2% of the total ion density and carry a parallel heat flux of approx.2 x 10 -2 ergs cm -2 s -2 . When integrated over an assumed 10 x 10 R/sub E/ bow shock emission area, this implies an upstream dissipation that may approach 10 17 to 10 18 ergs/s, comparable to a modest substorm

  9. Full characterization of laser-accelerated ion beams using Faraday cup, silicon carbide, and single-crystal diamond detectors

    Science.gov (United States)

    Margarone, D.; Krása, J.; Giuffrida, L.; Picciotto, A.; Torrisi, L.; Nowak, T.; Musumeci, P.; Velyhan, A.; Prokůpek, J.; Láska, L.; Mocek, T.; Ullschmied, J.; Rus, B.

    2011-05-01

    Multi-MeV beams of light ions have been produced using the 300 picosecond, kJ-class iodine laser, operating at the Prague Asterix Laser System facility in Prague. Real-time ion diagnostics have been performed by the use of various time-of-flight (TOF) detectors: ion collectors (ICs) with and without absorber thin films, new prototypes of single-crystal diamond and silicon carbide detectors, and an electrostatic ion mass spectrometer (IEA). In order to suppress the long photopeak induced by soft X-rays and to avoid the overlap with the signal from ultrafast particles, the ICs have been shielded with Al foil filters. The application of large-bandgap semiconductor detectors (>3 eV) ensured cutting of the plasma-emitted visible and soft-UV radiation and enhancing the sensitivity to the very fast proton/ion beams. Employing the IEA spectrometer, various ion species and charge states in the expanding laser-plasma have been determined. Processing of the experimental data based on the TOF technique, including estimation of the plasma fast proton maximum and peak energy, ion beam currents and total charge, total number of fast protons, as well as deconvolution processes, ion stopping power, and ion/photon transmission calculations for the different metallic filters used, are reported.

  10. CHICO, a heavy ion detector for Gammasphere

    CERN Document Server

    Simon, M W; Wu, C Y; Gray, R W; Teng, R; Long, C

    2000-01-01

    A 4 pi position-sensitive heavy-ion detector system, CHICO, has been developed primarily for use in conjunction with the 4 pi gamma-ray facility, Gammasphere. The CHICO detector comprises an array of 20 Parallel Plate Avalanche Counters (PPACs) covering 12 deg.

  11. A system to measure suprathermal electron distribution functions in toroidal plasmas by electron cyclotron wave absorption

    International Nuclear Information System (INIS)

    Boyd, D.A.; Skiff, F.; Gulick, S.

    1997-01-01

    A two-chord, four-beam suprathermal electron diagnostic has been installed on TdeV (B>1.5 T, R=0.86 m, a=0.25 m). Resonant absorption of extraordinary mode electron cyclotron waves is measured to deduce the chordal averaged suprathermal electron distribution function amplitude at the resonant momentum. Simultaneously counterpropagating beams permit good refractive loss cancellation. A nonlinear frequency sweep leads to a concentration of appropriately propagating power in a narrow range of time of flight, thus increasing the signal-to-noise ratio and facilitating the rejection of spurious reflections. Numerous measurements of electron distribution functions have been obtained during lower-hybrid current-drive experiments. copyright 1997 American Institute of Physics

  12. Ion space-charge effects in multi-GEM detectors: challenges and possible solutions for future applications

    CERN Document Server

    AUTHOR|(CDS)2079251; Streli, Christina

    Gaseous Electron Multiplier (GEM) detectors are well known both for stable operation under irradiation with high particle fluxes and high achievable effective gains. The aim of this thesis is two-fold: to investigate the limits of GEM detector operation due to space-charge effects, and to develop a means to reduce the magnitude of the observed effects and thus extend those limitations. The first part of the thesis presents a comprehensive study of the intrinsic limits of triple-GEM detectors under exposure to very high fluxes of soft X-rays or operation at very large effective gains. The behaviour of the effective gain, ion back-flow and the pulse-height spectra is explained in terms of the movement and accumulation of positive ions throughout the detector volume, resulting in distortions of the transfer and amplification fields. Numerical computations, and measurements on double-stage and single-stage detectors confirm the model describing the observed effects. Discussions on ways to extend the limits of gas...

  13. Development and characterization of semiconductor ion detectors for plasma diagnostics in the range over 0.3 keV

    Science.gov (United States)

    Cho, T.; Sakamoto, Y.; Hirata, M.; Kohagura, J.; Makino, K.; Kanke, S.; Takahashi, K.; Okamura, T.; Nakashima, Y.; Yatsu, K.; Tamano, T.; Miyoshi, S.

    1997-01-01

    For the purpose of plasma-ion-energy analyses in a wide-energy range from a few hundred eV to hundreds of keV, upgraded semiconductor detectors are newly fabricated and characterized using a test-ion-beam line from 0.3 to 12 keV. In particular, the detectable lowest-ion energy is drastically improved at least down to 0.3 keV; this energy is one to two orders-of-magnitude better than those for commercially available Si-surface-barrier diodes employed for previous plasma-ion diagnostics. A signal-to-noise ratio of two to three orders-of-magnitude better than that for usual metal-collector detectors is demonstrated for the compact-sized semiconductor along with the availability of the use under conditions of a good vacuum and a strong-magnetic field. Such characteristics are achieved due to the improving methods of the optimization of the thicknesses of a Si dead layer and a SiO2 layer, as well as the nitrogen-doping technique near the depletion layer along with minimizing impurity concentrations in Si. Such an upgraded capability of an extremely low-energy-ion detection with the low-noise characteristics enlarges research regimes of plasma-ion behavior using semiconductor detectors not only in the divertor regions of tokamaks but in wider spectra of open-field plasma devices including tandem mirrors. An application of the semiconductor ion detector for plasma-ion diagnostics is demonstrated in a specially designed ion-spectrometer structure.

  14. Dissociative electron attachment negative ion mass spectrometry: a chlorine-specific detector for gas chromatography

    Science.gov (United States)

    Curtis, Jonathan M.; Boyd, Robert K.

    1997-11-01

    This work describes the application of negative ion chemical ionization, optimized for dissociative electron attachment (DEA), to location of unknown trace chlorinated compounds in complex gas chromatograms by selected ion recording (SIR) of m / z 35 and 37. The DEA-SIR technique is compared with other GC detectors, including the electron capture detector, electrolytic conductivity detector, the atomic emission detector and the chemical reaction interface mass spectrometry method, with respect to selectivity for chlorine, sensitivity, linear dynamic range, and general robustness and ease of use. When applied to quantitative analysis of target analytes such as polychlorobiphenyls, the DEA-SIR method has potential problems arising from the possibility of suppression effects due to abundant co-eluting components, and possible alleviating measures are discussed. In addition to these practical investigations, literature information on the fundamental physical and chemical phenomena underlying the DEA process is summarized in order to guide future work on extension to other compound types and on general improvements to the technique.

  15. Study of ion cyclotron fluctuations. Application to the measurement of the ion temperature

    International Nuclear Information System (INIS)

    Lehner, T.

    1982-02-01

    A diagnostic technique for measuring the ion temperature of tokamak-type plasmas was developed. A theoretical study was made of the form factor associated with the ion cyclotron waves; the influence of Te/Ti on the frequency of the extrema of the dispersion relations was demonstrated. The different effects able to modify the spectral density (in particular the drift velocity and the impurities) were investigated. The mechanisms of suprathermal excitation of cylotron waves in tokamaks were reviewed together with the various effects stabilizing the spectrum: collisions, shear of the magnetic field lines. The experimental realization of the diagnostic technique is based on Thomson scattering by the electron density fluctuations [fr

  16. Shaping the solar wind electron temperature anisotropy by the interplay of core and suprathermal populations

    Science.gov (United States)

    Shaaban Hamd, S. M.; Lazar, M.; Poedts, S.; Pierrard, V.; Štverák

    2017-12-01

    We present the results of an advanced parametrization of the temperature anisotropy of electrons in the slow solar wind and the electromagnetic instabilities resulting from the interplay of their thermal core and suprathermal halo populations. A large set of observational data (from the Ulysses, Helios and Cluster missions) is used to parametrize these components and establish their correlations. Comparative analysis demonstrates for the first time a particular implication of the suprathermal electrons which are less dense but hotter than thermal electrons. The instabilities are significantly stimulated by the interplay of the core and halo populations, leading to lower thresholds which shape the observed limits of the temperature anisotropy for both the core and halo populations. This double agreement strongly suggests that the selfgenerated instabilities play the major role in constraining the electron anisotropy.

  17. Scintillator based detector for fast-ion losses induced by magnetohydrodynamic instabilities in the ASDEX upgrade tokamak.

    Science.gov (United States)

    García-Muñoz, M; Fahrbach, H-U; Zohm, H

    2009-05-01

    A scintillator based detector for fast-ion losses has been designed and installed on the ASDEX upgrade (AUG) tokamak [A. Herrmann and O. Gruber, Fusion Sci. Technol. 44, 569 (2003)]. The detector resolves in time the energy and pitch angle of fast-ion losses induced by magnetohydrodynamics (MHD) fluctuations. The use of a novel scintillator material with a very short decay time and high quantum efficiency allows to identify the MHD fluctuations responsible for the ion losses through Fourier analysis. A Faraday cup (secondary scintillator plate) has been embedded behind the scintillator plate for an absolute calibration of the detector. The detector is mounted on a manipulator to vary its radial position with respect to the plasma. A thermocouple on the inner side of the graphite protection enables the safety search for the most adequate radial position. To align the scintillator light pattern with the light detectors a system composed by a lens and a vacuum-compatible halogen lamp has been allocated within the detector head. In this paper, the design of the scintillator probe, as well as the new technique used to analyze the data through spectrograms will be described. A last section is devoted to discuss the diagnosis prospects of this method for ITER [M. Shimada et al., Nucl. Fusion 47, S1 (2007)].

  18. Ion distribution dynamics near the Earth's bow shock: first measurements with the 2D ion energy spectrometer CORALL on the INTERBALL/Tail-probe satellite

    Directory of Open Access Journals (Sweden)

    Yu. I. Yermolaev

    1997-05-01

    Full Text Available The dynamics of the ion distribution function near the Earth's bow shock is studied on the basis of quasi-3D measurements of ion energy spectra in the range of 30–24200 eV/q with the Russian-Cuban CORALL instrument on the INTERBALL/Tail-probe satellite. The instrument was designed for observations of magnetospheric plasma and measures ions, in an angular range of 36°–144° from the Earth-Sun direction. Ion populations generated by the Earth bow shock are often observed upstream from the bow shock. In the solar-wind stream compressed and heated by the passing of very dense magnetic cloud (CME, two types of these ion populations were measured upstream and before the bow shock crossing on 25 August 1995 at 07:37 UT. Both populations were observed in the energy range above 2 keV. At ~06:20 UT, when the angle between the direction of the interplanetary magnetic field and normal to the bow shock VBn was ≃ 43° the instrument observed a narrow, fast (~800 km/s field-aligned beam moving from the Earth. At ~07:30, when Bn ≃ 28°, the wide ion pitch-angle distribution was observed. A similar suprathermal ion population is observed in the magnetosheath simultaneously with the solar-wind ion population being heated and deflected from the Sun-Earth direction. The similarity of observations during the mentioned time-interval and under usual solar-wind conditions allows us to conclude that types of suprathermal ion populations upstream and downstream from the bow shock do not depend on the solar-wind disturbance generated by magnetic cloud.

  19. Origin and Properties of Quiet-time 0.11–1.28 MeV Nucleon{sup −1} Heavy-ion Population Near 1 au

    Energy Technology Data Exchange (ETDEWEB)

    Dayeh, M. A.; Desai, M. I.; Ebert, R. W. [Space Science and Engineering Division, Southwest Research Institute, San Antonio, TX 78238 (United States); Mason, G. M. [Johns Hopkins University Applied Physics Laboratory, Laurel, MD 20723 (United States); Farahat, A., E-mail: maldayeh@swri.edu [Department of Physics, College of Applied and Supporting Studies, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2017-02-01

    Using measurements from the Advanced Composition Explorer /Ultra-Low Energy Isotope Spectrometer near 1 au, we surveyed the composition and spectra of heavy ions (He-through-Fe) during quiet times from 1998 January 1 to 2015 December 31 at suprathermal energies between ∼0.11 and ∼1.28 MeV nucleon{sup −1}. The selected time period covers the maxima of solar cycles 23 and 24 and the extended solar minimum in between. We find the following. (1) The number of quiet hours in each year correlates well with the sunspot number, year 2009 was the quietest for about 82% of the time. (2) The composition of the quiet-time suprathermal heavy-ion population ({sup 3}He, C-through-Fe) correlates well with the level of solar activity, exhibiting SEP-like composition signatures during solar maximum, and CIR- or solar wind-like composition during solar minimum. (3) The heavy-ion (C–Fe) spectra exhibit suprathermal tails at energies of 0.11–0.32 MeV nucleon{sup −1} with power-law spectral indices ranging from 1.40 to 2.97. Fe spectra soften (steepen, i.e., spectral index increases) smoothly with increasing energies compared with Fe, indicating a rollover behavior of Fe at higher energies (0.45–1.28 MeV nucleon{sup −1}). (4) Spectral indices of Fe and O do not appear to exhibit clear solar cycle dependence. (2) and (3) imply that during IP quiet times and at energies above ∼0.1 MeV nucleon{sup −1}, the IP medium is dominated by material from prior solar and interplanetary events. We discuss the implications of these extended observations in the context of the current understanding of the suprathermal ion population near 1 au.

  20. Microdosimetry for a carbon ion beam using track-etched detectors

    International Nuclear Information System (INIS)

    Ambrozova, I.; Ploc, O.; Davidkova, M.; Vondracek, V.; Sefl, M.; Stepan, V.; Pachnerova Brabcova, K.; Incerti, S.

    2015-01-01

    Track-etched detectors (TED) have been used as linear energy transfer (LET) spectrometers in heavy ion beams for many years. LET spectra and depth -dose distribution of a carbon ion beam were measured behind polymethylmethacrylate degraders at Heavy Ion Medical Accelerator in Chiba, Japan. The measurements were performed along monoenergetic beam with energy 290 MeV u -1 in different positions: (1) at beam extraction area, (2) at beginning, (3) maximum and (4) behind the Bragg peak region (0, 117, 147 and 151 mm of water-equivalent depth, respectively). The LET spectra inside and outside of the primary ion beam have been evaluated. TED record only heavy charged particles with LET above 8 -10 keV μm -1 , while electrons and ions with lower LET are not detected. The Geant4 simulation toolkit version 4.9.6.P01 has been used to estimate the contribution of non-detected particles to absorbed dose. Presented results demonstrate the applicability of TED for microdosimetry measurements in therapeutic carbon ion beams. (authors)

  1. Quiet-time 0.04 - 2 MeV/nucleon Ions at 1 AU in Solar Cycles 23 and 24

    Science.gov (United States)

    Zeldovich, M. A.; Logachev, Y. I.; Kecskeméty, K.

    2018-01-01

    The fluxes of 3He, 4He, C, O, and Fe ions at low energies (about 0.04 - 2 MeV/nucleon) are studied during quiet periods in Solar Cycles (SC) 23 and 24 using data from the ULEIS/ACE instrument. In selecting quiet periods (the definition is given in Section 2.1), additional data from EPHIN/SOHO and EPAM/ACE were also used. The analysis of the ion energy spectra and their relative abundances shows that their behavior is governed by their first-ionization potential. Substantial differences in the ion energy spectra in two consecutive solar cycles are observed during the quiet periods selected. Quiet-time fluxes are divided into three distinct types according to the {˜} 80 - 320 keV/nucleon Fe/O ratio. Our results confirm the earlier observation that these types of suprathermal particles have different origins, that is, they represent different seed populations that are accelerated by different processes. Except for the solar activity minimum, the Fe/O ratio during quiet-time periods correspond either to the abundances of ions in particle fluxes accelerated in impulsive solar flares or to the mean abundances of elements in the solar corona. At the activity minimum, this ratio takes on values that are characteristic for the solar wind. These results indicate that the background fluxes of low-energy particles in the ascending, maximum, and decay phases of the solar cycle include significant contributions from both coronal particles accelerated to suprathermal energies and ions accelerated in small impulsive solar flares rich in Fe, while the contribution of remnants from earlier SEP events cannot be excluded. The comparison of suprathermal ion abundances during the first five years of SC 23 and SC 24 suggests that the quiet-time and non-quiet fluxes of Fe and 3He were lower in SC 24.

  2. Helium ion distributions in a 4 kJ plasma focus device by 1 mm-thick large-size polycarbonate detectors

    Energy Technology Data Exchange (ETDEWEB)

    Sohrabi, M., E-mail: dr_msohrabi@yahoo.com; Habibi, M.; Ramezani, V.

    2014-11-14

    Helium ion beam profile, angular and iso-ion beam distributions in 4 kJ Amirkabir plasma focus (APF) device were effectively observed by the unaided eyes and studied in single 1 mm-thick large-diameter (20 cm) polycarbonate track detectors (PCTD). The PCTDs were processed by 50 Hz–HV electrochemical etching using a large-size ECE chamber. The results show that helium ions produced in the APF device have a ring-shaped angular distribution peaked at an angle of ∼±60° with respect to the top of the anode. Some information on the helium ion energy and distributions is also provided. The method is highly effective for ion beam studies. - Highlights: • Helium iso-ion beam profile and angular distributions were studied in the 4 kJ APF device. • Large-area 1 mm-thick polycarbonate detectors were processed by 50 Hz-HV ECE. • Helium ion beam profile and distributions were observed by unaided eyes in a single detector. • Helium ion profile has ring-shaped distributions with energies lower at the ring location. • Helium iso-ion track density, diameter and energy distributions are estimated.

  3. A method for ion distribution function evaluation using escaping neutral atom kinetic energy samples

    International Nuclear Information System (INIS)

    Goncharov, P.R.; Ozaki, T.; Veshchev, E.A.; Sudo, S.

    2008-01-01

    A reliable method to evaluate the probability density function for escaping atom kinetic energies is required for the analysis of neutral particle diagnostic data used to study the fast ion distribution function in fusion plasmas. Digital processing of solid state detector signals is proposed in this paper as an improvement of the simple histogram approach. Probability density function for kinetic energies of neutral particles escaping from the plasma has been derived in a general form taking into account the plasma ion energy distribution, electron capture and loss rates, superposition along the diagnostic sight line and the magnetic surface geometry. A pseudorandom number generator has been realized that enables a sample of escaping neutral particle energies to be simulated for given plasma parameters and experimental conditions. Empirical probability density estimation code has been developed and tested to reconstruct the probability density function from simulated samples assuming. Maxwellian and classical slowing down plasma ion energy distribution shapes for different temperatures and different slowing down times. The application of the developed probability density estimation code to the analysis of experimental data obtained by the novel Angular-Resolved Multi-Sightline Neutral Particle Analyzer has been studied to obtain the suprathermal particle distributions. The optimum bandwidth parameter selection algorithm has also been realized. (author)

  4. The Nuclotron-based Ion Collider Facility Project. The Physics Programme for the Multi-Purpose Detector

    Science.gov (United States)

    Geraksiev, N. S.; MPD Collaboration

    2018-05-01

    The Nuclotron-based Ion Collider fAcility (NICA) is a new accelerator complex being constructed at the Joint Institute for Nuclear Research (JINR). The general objective of the project is to provide beams for the experimental study of hot and dense strongly interacting QCD matter. The heavy ion programme includes two planned detectors: BM@N (Baryonic Matter at Nuclotron) a fixed target experiment with extracted Nuclotron beams; and MPD (MultiPurpose Detector) a collider mode experiment at NICA. The accelerated particles can range from protons and light nuclei to gold ions. Beam energies will span\\sqrt{s}=12-27 GeV with luminosity L ≥ 1 × 1030 cm‑2s‑1 and \\sqrt{{s}NN}=4-11 GeV and average luminosity L = 1 × 1027cm‑2 s ‑1(for 197Au79+), respectively. A third experiment for spin physics is planned with the SPD (Spin Physics Detector) at the NICA collider in polarized beams mode. A brief overview of the MPD is presented along with several observables in the MPD physics programme.

  5. Ripple enhanced transport of suprathermal alpha particles

    International Nuclear Information System (INIS)

    Tani, K.; Takizuka, T.; Azumi, M.

    1986-01-01

    The ripple enhanced transport of suprathermal alpha particles has been studied by the newly developed Monte-Carlo code in which the motion of banana orbit in a toroidal field ripple is described by a mapping method. The existence of ripple-resonance diffusion has been confirmed numerically. We have developed another new code in which the radial displacement of banana orbit is given by the diffusion coefficients from the mapping code or the orbit following Monte-Carlo code. The ripple loss of α particles during slowing down has been estimated by the mapping model code as well as the diffusion model code. From the comparison of the results with those from the orbit-following Monte-Carlo code, it has been found that all of them agree very well. (author)

  6. Concept for an Electron Ion Collider (EIC) detector built around the BaBar solenoid

    OpenAIRE

    PHENIX Collaboration; Adare, A.; Aidala, C.; Ajitanand, N. N.; Akiba, Y.; Akimoto, R.; Alfred, M.; Apadula, N.; Aramaki, Y.; Asano, H.; Atomssa, E. T.; Awes, T. C.; Azmoun, B.; Babintsev, V.; Bai, M.

    2014-01-01

    The PHENIX collaboration presents here a concept for a detector at a future Electron Ion Collider (EIC). The EIC detector proposed here, referred to as ePHENIX, will have excellent performance for a broad range of exciting EIC physics measurements, providing powerful investigations not currently available that will dramatically advance our understanding of how quantum chromodynamics binds the proton and forms nuclear matter.

  7. The Diogene detector and relativistic heavy ion collisions. First experiments at Saturne

    International Nuclear Information System (INIS)

    Alard, J.P.; Augerat, J.; Babinet, R.

    1983-01-01

    Relativistic heavy ion collisions are important for a study of nuclear matter properties, at high density temperature. The use of high multiplicity detectors, with a 4π solid angle, permit more exclusive experiments which are essential for an approach of collision mechanisms and for the observation of eventual exotic phenomena. Also, we present some preliminary results, obtained with a 800 MeV/nucl α particle beam and concerning the performances of the Diogene detector actually setted up at the Laboratoire National Saturne at Saclay [fr

  8. Position sensitive plastic scintillating fibre-detectors for heavy ion detection

    Energy Technology Data Exchange (ETDEWEB)

    Scholl, Sebastian; Tscheuschner, Joachim; Paschalis, Stefanos; Aumann, Thomas; Scheit, Heiko [Institut fuer Kernphysik, Technische Universitaet Darmstadt (Germany)

    2016-07-01

    The R{sup 3}B (Reactions with Relativistic Radioactive Beams) experiment at FAIR will be able to perform kinematically complete measurements of reactions with relativistic heavy-ion beams up to 1 AGeV. In order to track the beam before the target and to determine the mass number of the scattered nucleus after the reaction, five fibre detectors with sizes between 10.24 x 10.24 cm{sup 2} and 120 x 80 cm{sup 2} are going to be built for the R{sup 3}B setup. These fibre detectors will provide x-y-position of the trajectory of charged particles after the reaction target. The light from the fibre detector is sensed using MPPCs (Multi Pixel Photon Counter). For the readout of the MPPCs we test different electronics. In this contribution we present results obtained using an α-source and a LED light source to generate light in the fibre and use the PADI-VFTX for readout.

  9. Measurement of secondary radiation during ion beam therapy with the pixel detector Timepix

    Science.gov (United States)

    Martišíková, Mária; Jakubek, Jan; Granja, Carlos; Hartmann, Bernadette; Opálka, Lukáš; Pospíšil, Stanislav; Jäkel, Oliver

    2011-11-01

    In ion beam therapy the finite range of the ion beams in tissue and the presence of the Bragg-peak are exploited. Unpredictable changes in the patient`s condition can alter the range of the ion beam in the body. Therefore it is desired to verify the actual ion range during the treatment, preferably in a non-invasive way. Positron emission tomography (PET) has been used successfully to monitor the applied dose distributions. This method however suffers from limited applicability and low detection efficiency. In order to increase the detection efficiency and to decrease the uncertainties, in this study we investigate the possibility to measure secondary charged particles emerging from the patient during irradiation. An initial experimental study to register the particle radiation coming out of a patient phantom during the therapy was performed at the Heidelberg Ion Beam Therapy Center (HIT) in Germany. A static narrowly-focused beam of carbon ions was directed into a head phantom. The emerging secondary radiation was measured with the position-sensitive Timepix detector outside of the phantom. The detector, developed by the Medipix Collaboration, consists of a silicon sensor bump bonded to a pixelated readout chip (256 × 256 pixels with 55 μm pitch). Together with the USB-based readout interface, Timepix can operate as an active nuclear emulsion registering single particles online with 2D-track visualization. In this contribution we measured the signal behind the head phantom and investigated its dependence on the beam energy (corresponding to beam range in water 2-30 cm). Furthermore, the response was measured at four angles between 0 and 90 degrees. At all investigated energies some signal was registered. Its pattern corresponds to ions. Differences in the total amount of signal for different beam energies were observed. The time-structure of the signal is correlated with that of the incoming beam, showing that we register products of prompt processes. Such

  10. Measurement of secondary radiation during ion beam therapy with the pixel detector Timepix

    International Nuclear Information System (INIS)

    Martišíková, Mária; Hartmann, Bernadette; Jäkel, Oliver; Jakubek, Jan; Granja, Carlos; Opálka, Lukáš; Pospíšil, Stanislav

    2011-01-01

    In ion beam therapy the finite range of the ion beams in tissue and the presence of the Bragg-peak are exploited. Unpredictable changes in the patient's condition can alter the range of the ion beam in the body. Therefore it is desired to verify the actual ion range during the treatment, preferably in a non-invasive way. Positron emission tomography (PET) has been used successfully to monitor the applied dose distributions. This method however suffers from limited applicability and low detection efficiency. In order to increase the detection efficiency and to decrease the uncertainties, in this study we investigate the possibility to measure secondary charged particles emerging from the patient during irradiation. An initial experimental study to register the particle radiation coming out of a patient phantom during the therapy was performed at the Heidelberg Ion Beam Therapy Center (HIT) in Germany. A static narrowly-focused beam of carbon ions was directed into a head phantom. The emerging secondary radiation was measured with the position-sensitive Timepix detector outside of the phantom. The detector, developed by the Medipix Collaboration, consists of a silicon sensor bump bonded to a pixelated readout chip (256 × 256 pixels with 55 μm pitch). Together with the USB-based readout interface, Timepix can operate as an active nuclear emulsion registering single particles online with 2D-track visualization. In this contribution we measured the signal behind the head phantom and investigated its dependence on the beam energy (corresponding to beam range in water 2–30 cm). Furthermore, the response was measured at four angles between 0 and 90 degrees. At all investigated energies some signal was registered. Its pattern corresponds to ions. Differences in the total amount of signal for different beam energies were observed. The time-structure of the signal is correlated with that of the incoming beam, showing that we register products of prompt processes. Such

  11. Interplanetary ions during an energetic storm particle event - The distribution function from solar wind thermal energies to 1.6 MeV

    Science.gov (United States)

    Gosling, J. T.; Asbridge, J. R.; Bame, S. J.; Feldman, W. C.; Zwickl, R. D.; Paschmann, G.; Sckopke, N.; Hynds, R. J.

    1981-01-01

    An ion velocity distribution function of the postshock phase of an energetic storm particle (ESP) event is obtained from data from the ISEE 2 and ISEE 3 experiments. The distribution function is roughly isotropic in the solar wind frame from solar wind thermal energies to 1.6 MeV. The ESP event studied (8/27/78) is superposed upon a more energetic particle event which was predominantly field-aligned and which was probably of solar origin. The observations suggest that the ESP population is accelerated directly out of the solar wind thermal population or its quiescent suprathermal tail by a stochastic process associated with shock wave disturbance. The acceleration mechanism is sufficiently efficient so that approximately 1% of the solar wind population is accelerated to suprathermal energies. These suprathermal particles have an energy density of approximately 290 eV cubic centimeters.

  12. Turbulent ion heating in TCV Tokamak plasmas

    International Nuclear Information System (INIS)

    Schlatter, Ch.

    2009-08-01

    charge exchange measurements, by doping the plasma with ion neutralisation targets injected with the diagnostic neutral beam (DNBI), were used to absolutely calibrate the NPA. Advanced modelling of the measured hydrogenic charge exchange spectra with the neutralisation and neutral transport codes KN1D and DOUBLE-TCV permitted a calculation of the absolute neutral density profiles of the plasma species.The energisation and the properties of fast ions were studied in dedicated, low density, cold ion, hot electron plasmas, resonantly heated at the second harmonic of the electron cyclotron frequency. The ion acceleration occurs on a characteristic timescale in the sub-millisecond range and comprises up to 20 % of the plasma ions. The number of fast ions n i s and their effective temperature T i s are found to depend strongly on the bulk and suprathermal electron parameters, in particular T i s ≥ T e b (electron bulk) and n i s ∼ v de (toroidal electron drift speed). The suprathermal electrons, abundantly generated in plasmas subjected to ECCD, are diagnosed with perpendicular and oblique viewing electron cyclotron emission (ECE) antennas and the measured frequency spectra are reconstructed with the relativistic ECE radiation balance code NOTEC-TCV. With steady-state ECRH and ECCD, the fast ion population reaches an equilibrium state. The spatial fast ion temperature profile is broad, of similar shape compared to the bulk ion temperature profile. The hottest suprathermal temperature observed is T i s ≥ 6 keV. Various potential ion acceleration mechanisms were examined for relevance in the TCV parameter range. The simultaneous wave-electron and wave-ion resonances of ion acoustic turbulence (IAT) show the best correlation with the available experimental knowledge. Ion acoustic waves are emitted by the weakly relativistic circulating electrons and are mainly Landau damped onto the ions. Destabilisation of IAT is markedly facilitated by the important degree of

  13. Effect of suprathermal electrons on the intensity and Doppler frequency of electron plasma lines

    Directory of Open Access Journals (Sweden)

    P. Guio

    Full Text Available In an incoherent scattering radar experiment, the spectral measurement of the so-called up- and downshifted electron plasma lines provides information about their intensity and their Doppler frequency. These two spectral lines correspond, in the backscatter geometry, to two Langmuir waves travelling towards and away from the radar. In the daytime ionosphere, the presence of a small percentage of photoelectrons produced by the solar EUV of the total electron population can excite or damp these Langmuir waves above the thermal equilibrium, resulting in an enhancement of the intensity of the lines above the thermal level. The presence of photo-electrons also modifies the dielectric response function of the plasma from the Maxwellian and thus influences the Doppler frequency of the plasma lines. In this paper, we present a high time-resolution plasma-line data set collected on the Eiscat VHF radar. The analysed data are compared with a model that includes the effect of a suprathermal electron population calculated by a transport code. By comparing the intensity of the analysed plasma lines data to our model, we show that two sharp peaks in the electron suprathermal distribution in the energy range 20-30 eV causes an increased Landau damping around 24.25 eV and 26.25 eV. We have identified these two sharp peaks as the effect of the photoionisation of N2 and O by the intense flux of monochromatic HeII radiation of wavelength 30.378 nm (40.812 eV created in the chromospheric network and coronal holes. Furthermore, we see that what would have been interpreted as a mean Doppler drift velocity for a Maxwellian plasma is actually a shift of the Doppler frequency of the plasma lines due to suprathermal electrons.

    Key words. Ionosphere (electric fields and currents; solar radiation and cosmic ray effects

  14. Effect of suprathermal electrons on the intensity and Doppler frequency of electron plasma lines

    Directory of Open Access Journals (Sweden)

    P. Guio

    1999-07-01

    Full Text Available In an incoherent scattering radar experiment, the spectral measurement of the so-called up- and downshifted electron plasma lines provides information about their intensity and their Doppler frequency. These two spectral lines correspond, in the backscatter geometry, to two Langmuir waves travelling towards and away from the radar. In the daytime ionosphere, the presence of a small percentage of photoelectrons produced by the solar EUV of the total electron population can excite or damp these Langmuir waves above the thermal equilibrium, resulting in an enhancement of the intensity of the lines above the thermal level. The presence of photo-electrons also modifies the dielectric response function of the plasma from the Maxwellian and thus influences the Doppler frequency of the plasma lines. In this paper, we present a high time-resolution plasma-line data set collected on the Eiscat VHF radar. The analysed data are compared with a model that includes the effect of a suprathermal electron population calculated by a transport code. By comparing the intensity of the analysed plasma lines data to our model, we show that two sharp peaks in the electron suprathermal distribution in the energy range 20-30 eV causes an increased Landau damping around 24.25 eV and 26.25 eV. We have identified these two sharp peaks as the effect of the photoionisation of N2 and O by the intense flux of monochromatic HeII radiation of wavelength 30.378 nm (40.812 eV created in the chromospheric network and coronal holes. Furthermore, we see that what would have been interpreted as a mean Doppler drift velocity for a Maxwellian plasma is actually a shift of the Doppler frequency of the plasma lines due to suprathermal electrons.Key words. Ionosphere (electric fields and currents; solar radiation and cosmic ray effects

  15. Fail-safe ion chamber errant beam detector tailored for personnel protection

    International Nuclear Information System (INIS)

    Plum, M.A.; Browman, A.A.; Brown, D.; Lee, D.M.; McCabe, C.W.

    1989-01-01

    This fail-safe ion chamber system is designed to be part of the personnel safety system (PSS) for the Los Alamos neutron Scattering Center (LANSCE) at the Los Alamos National Laboratory. Its job is to protect the occupants of the experimental areas from large radiation doses caused by errant beam conditions during beam transport from the Proton Storage Ring (PSR) to the LANSCE neutron spallation target. Due to limited shielding between the beam transport line and the experimental area only if the beam losses in the transport line are very low. The worst case beam spill scenario is calculated to result in a personnel exposure of about 0.01 Gys/s (1 rad/s). Although the preferred solution is to increase the bulk shielding between the beam line and the experimental area, the physical dimensions of the site do not permit an adequate amount of shielding to be added. The solution adopted is a layered system of three types of highly reliable detector systems: a current limiter system located in the beam line, a neutron detector system located in the experimental areas, and an ion chamber system located on the walls of the beam line tunnels. The ion chamber system is capable of shutting off the beam in less than 0.5 s, resulting in a worst case personnel exposure of 0.005 Gys (0.5 rad). 4 figs

  16. Statistics of counter-streaming solar wind suprathermal electrons at solar minimum: STEREO observations

    Directory of Open Access Journals (Sweden)

    B. Lavraud

    2010-01-01

    Full Text Available Previous work has shown that solar wind suprathermal electrons can display a number of features in terms of their anisotropy. Of importance is the occurrence of counter-streaming electron patterns, i.e., with "beams" both parallel and anti-parallel to the local magnetic field, which is believed to shed light on the heliospheric magnetic field topology. In the present study, we use STEREO data to obtain the statistical properties of counter-streaming suprathermal electrons (CSEs in the vicinity of corotating interaction regions (CIRs during the period March–December 2007. Because this period corresponds to a minimum of solar activity, the results are unrelated to the sampling of large-scale coronal mass ejections, which can lead to CSE owing to their closed magnetic field topology. The present study statistically confirms that CSEs are primarily the result of suprathermal electron leakage from the compressed CIR into the upstream regions with the combined occurrence of halo depletion at 90° pitch angle. The occurrence rate of CSE is found to be about 15–20% on average during the period analyzed (depending on the criteria used, but superposed epoch analysis demonstrates that CSEs are preferentially observed both before and after the passage of the stream interface (with peak occurrence rate >35% in the trailing high speed stream, as well as both inside and outside CIRs. The results quantitatively show that CSEs are common in the solar wind during solar minimum, but yet they suggest that such distributions would be much more common if pitch angle scattering were absent. We further argue that (1 the formation of shocks contributes to the occurrence of enhanced counter-streaming sunward-directed fluxes, but does not appear to be a necessary condition, and (2 that the presence of small-scale transients with closed-field topologies likely also contributes to the occurrence of counter-streaming patterns, but only in the slow solar wind prior to

  17. Nuclear radiation detector based on ion implanted p-n junction in 4H-SiC

    International Nuclear Information System (INIS)

    Vervisch, V.; Issa, F.; Ottaviani, L.; Lazar, M.; Kuznetsov, A.; Szalkai, D.; Klix, A.; Lyoussi, A.; Vermeeren, L.; Hallen, A.

    2013-06-01

    In this paper, we propose a new device detector based on ion implanted p-n junction in 4H-SiC for nuclear instrumentation. We showed the interest to use 10 Boron as a Neutron Converter Layer in order to detect thermal neutrons. We present the main results obtained during irradiation tests performed in the Belgian Reactor 1. We show the capability of our detector by means of first results of the detector response at different reverse voltage biases and at different reactor power (authors)

  18. Simultaneous measurements of ion and electron currents using a novel compact electrostatic end-loss-current detector

    Science.gov (United States)

    Hirata, M.; Miyake, Y.; Cho, T.; Kohagura, J.; Numakura, T.; Shimizu, K.; Ito, M.; Kiminami, S.; Morimoto, N.; Hirai, K.; Yamagishi, T.; Miyata, Y.; Nakashima, Y.; Miyoshi, S.; Ogura, K.; Kondoh, T.; Kariya, T.

    2006-10-01

    For the purpose of end-loss-ion and -electron analyses in open-field plasmas, a compact-sized electrostatic end-loss-current detector is proposed on the basis of a self-collection principle for suppressing the effects of secondary-electron emission from a metal collector. For employing this specific method, it is worth noting that no further additional magnetic systems except the ambient open-ended magnetic fields are required in the detector operation. This characteristic property provides a compactness of the total detection system and availability for its use in plasma confinement devices without disturbing plasma-confining magnetic fields. The detector consists of a set of parallel metal plates with respect to lines of ambient magnetic forces of a plasma device for analyzing incident ion currents along with a grid for shielding the collector against strays due to the metal-plate biasing. The characterization experiments are carried out by the use of a test-ion-beam line along with an additional use of a Helmholtz coil system for the formation of open magnetic fields similar to those in the GAMMA 10 end region. The applications of the developed end-loss-current detector in the GAMMA 10 plasma experiments are demonstrated under the conditions with simultaneous incidence of energetic electrons produced by electron-cyclotron heatings for end-loss-plugging potential formation.

  19. A novel method for simultaneous observations of plasma ion and electron temperatures using a semiconductor-detector array

    International Nuclear Information System (INIS)

    Cho, T.; Numakura, T.; Kohagura, J.; Hirata, M.; Minami, R.; Watanabe, H.; Sasuga, T.; Nishizawa, Y.; Yoshida, M.; Nagashima, S.; Nakashima, Y.; Ogura, K.; Tamano, T.; Yatsu, K.; Miyoshi, S.

    2002-01-01

    A new method for a simultaneous observation of both plasma ion and electron temperatures is proposed using one semiconductor-detector array alone. This method will provide a new application of semiconductor-detector arrays for monitoring the key parameter set of nuclear-fusion triple product (i.e., ion temperatures, densities, and confinement time) as well as for clarifying physics mechanisms of energy transport between plasma ions and electrons under various plasma confining conditions. This method is developed on the basis of an alternative 'positive' use of a semiconductor 'dead layer'; that is, an SiO 2 layer is employed as a reliable ultra-thin energy analysis filter for low-energy charge-exchanged neutral particles from plasmas ranging in ion temperatures from 0.1 to several tens of kilo-electron-volts. Using recent fabrication techniques for the thin and uniform SiO 2 layers of the order of tens to hundreds of angstrom, our computer simulation and its experimental verification show the availability of such semiconductors for distinguishing neutral particles (for ion temperatures) from X-rays (for electron temperatures). These are simultaneously emitted from the plasmas into semiconductor detectors; however, we employ their quite different penetration lengths and the resultant different deposition depths and profiles in semiconductor materials. As a result, their output signals are distinguishable for these two different and fundamental species of plasmas

  20. Current signal of silicon detectors facing charged particles and heavy ions; Reponse en courant des detecteurs silicium aux particules chargees et aux ions lourds

    Energy Technology Data Exchange (ETDEWEB)

    Hamrita, H

    2005-07-01

    This work consisted in collecting and studying for the first time the shapes of current signals obtained from charged particles or heavy ions produced by silicon detectors. The document is divided into two main parts. The first consisted in reducing the experimental data obtained with charged particles as well as with heavy ions. These experiments were performed at the Orsay Tandem and at GANIL using LISE. These two experiments enabled us to create a data base formed of current signals with various shapes and various times of collection. The second part consisted in carrying out a simulation of the current signals obtained from the various ions. To obtain this simulation we propose a new model describing the formation of the signal. We used the data base of the signals obtained in experiments in order to constrain the three parameters of our model. In this model, the charge carriers created are regarded as dipoles and their density is related to the dielectric polarization in the silicon detector. This phenomenon induces an increase in permittivity throughout the range of the incident ion and consequently the electric field between the electrodes of the detector is decreased inside the trace. We coupled with this phenomenon a dissociation and extraction mode of the charge carriers so that they can be moved in the electric field. (author)

  1. Low energy RBS-channeling measurement system with the use of a time-of-flight scattered ion detector

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, Masataka; Kobayashi, Naoto; Hayashi, Nobuyuki [Electrotechnical Lab., Tsukuba, Ibaraki (Japan)

    1996-07-01

    We have developed a low energy Rutherford backscattering spectrometry-ion channeling measurement system for the analysis of thin films and solid surfaces with the use of several tens keV hydrogen ions and a time-of-flight particle energy spectrometer. For the detection of the scattered ions new TOF spectrometer has been developed, which consists of two micro-channel-plate detectors. The pulsing of the primary ion beam is not necessary for this type of TOF measurement, and it is possible to observe continues scattered ion beams. The dimension of whole system is very compact compared to the conventional RBS-channeling measurement system with the use of MeV He ions. The energy resolution, {delta} E/E, for 25 keV H{sup +} was 4.1%, which corresponds to the depth resolution of 4.8 nm for silicon. The depth resolution of our system is better than that of conventional RBS system with MeV helium ions and solid state detectors. We have demonstrated the ion channeling measurement by this system with 25 keV hydrogen ions. The system can be available well to the analysis of thin films and solid surfaces with the use of the ion channeling effect. The observation of the reaction between Fe and hydrogen terminated silicon surface was also demonstrated. (J.P.N.)

  2. Interaction of suprathermal solar wind electron fluxes with sheared whistler waves: fan instability

    Directory of Open Access Journals (Sweden)

    C. Krafft

    Full Text Available Several in situ measurements performed in the solar wind evidenced that solar type III radio bursts were some-times associated with locally excited Langmuir waves, high-energy electron fluxes and low-frequency electrostatic and electromagnetic waves; moreover, in some cases, the simultaneous identification of energetic electron fluxes, Langmuir and whistler waves was performed. This paper shows how whistlers can be excited in the disturbed solar wind through the so-called "fan instability" by interacting with energetic electrons at the anomalous Doppler resonance. This instability process, which is driven by the anisotropy in the energetic electron velocity distribution along the ambient magnetic field, does not require any positive slope in the suprathermal electron tail and thus can account for physical situations where plateaued reduced electron velocity distributions were observed in solar wind plasmas in association with Langmuir and whistler waves. Owing to linear calculations of growth rates, we show that for disturbed solar wind conditions (that is, when suprathermal particle fluxes propagate along the ambient magnetic field, the fan instability can excite VLF waves (whistlers and lower hybrid waves with characteristics close to those observed in space experiments.

    Key words. Space plasma physics (waves and instabilities – Radio Science (waves in plasma – Solar physics, astrophysics and astronomy (radio emissions

  3. Interaction of suprathermal solar wind electron fluxes with sheared whistler waves: fan instability

    Directory of Open Access Journals (Sweden)

    C. Krafft

    2003-07-01

    Full Text Available Several in situ measurements performed in the solar wind evidenced that solar type III radio bursts were some-times associated with locally excited Langmuir waves, high-energy electron fluxes and low-frequency electrostatic and electromagnetic waves; moreover, in some cases, the simultaneous identification of energetic electron fluxes, Langmuir and whistler waves was performed. This paper shows how whistlers can be excited in the disturbed solar wind through the so-called "fan instability" by interacting with energetic electrons at the anomalous Doppler resonance. This instability process, which is driven by the anisotropy in the energetic electron velocity distribution along the ambient magnetic field, does not require any positive slope in the suprathermal electron tail and thus can account for physical situations where plateaued reduced electron velocity distributions were observed in solar wind plasmas in association with Langmuir and whistler waves. Owing to linear calculations of growth rates, we show that for disturbed solar wind conditions (that is, when suprathermal particle fluxes propagate along the ambient magnetic field, the fan instability can excite VLF waves (whistlers and lower hybrid waves with characteristics close to those observed in space experiments.Key words. Space plasma physics (waves and instabilities – Radio Science (waves in plasma – Solar physics, astrophysics and astronomy (radio emissions

  4. High-accuracy fluence determination in ion beams using fluorescent nuclear track detectors

    DEFF Research Database (Denmark)

    Osinga, J.-M.; Akselrod, M.S.; Herrmann, Rochus

    2013-01-01

    We present an approach to use Al2O3:C,Mg-based fluorescent nuclear track detectors (FNTDs) and confocal laser scanning microscopy as a semiautomatic tool for fluence measurements in clinical ion beams. The method was found to cover a linear energy transfer (LET) range from at least L∞(Al2O3) = 0...

  5. Heavy Ion Physics at the LHC with the ATLAS Detector

    CERN Document Server

    Steinberg, P.

    2007-01-01

    The ATLAS detector at CERN will provide a high-resolution longitudinally-segmented calorimeter and precision tracking for the upcoming study of heavy ion collisions at the LHC (sqrt{s_{NN}=5520 GeV). The calorimeter covers |eta|<5 with both electromagnetic and hadronic sections, while the inner detector spectrometer covers |eta|<2.5. ATLAS will study a full range of observables necessary to characterize the hot and dense matter formed at the LHC. Global measurements (particle multiplicities, collective flow) will provide access into its thermodynamic and hydrodynamic properties. Measuring complete jets out to 100's of GeV will allow detailed studies of energy loss and its effect on jets. Quarkonia will provide a handle on deconfinement mechanisms. ATLAS will also study the structure of the nucleon and nucleus using forward physics probes and ultraperipheral collisions, both enabled by segmented Zero Degree Calorimeters.

  6. Heavy ion physics at the LHC with the ATLAS detector

    International Nuclear Information System (INIS)

    Steinberg, P

    2007-01-01

    The ATLAS detector at CERN will provide a high-resolution longitudinally segmented calorimeter and precision tracking for the upcoming study of heavy ion collisions at the LHC (√s NN = 5520 GeV). The calorimeter covers |η| < 5 with both electromagnetic and hadronic sections, while the inner detector spectrometer covers |η| < 2.5. ATLAS will study a full range of observables necessary to characterize the hot and dense matter formed at the LHC. Global measurements (particle multiplicities, collective flow) will provide access into its thermodynamic and hydrodynamic properties. Measuring complete jets out to 100's of GeV will allow detailed studies of energy loss and its effect on jets. Quarkonia will provide a handle on deconfinement mechanisms. ATLAS will also study the structure of the nucleon and nucleus using forward physics probes and ultraperipheral collisions, both enabled by segmented zero degree calorimeters

  7. Performance of a position sensitive Si(Li) x-ray detector dedicated to Compton polarimetry of stored and trapped highly-charged ions

    International Nuclear Information System (INIS)

    Weber, G; Braeuning, H; Hess, S; Maertin, R; Spillmann, U; Stoehlker, Th

    2010-01-01

    We report on a novel two-dimensional position sensitive Si(Li) detector dedicated to Compton polarimetry of x-ray radiation arising from highly-charged ions. The performance of the detector system was evaluated in ion-atom collision experiments at the ESR storage ringe at GSI, Darmstadt. Based on the data obtained, the polarimeter efficiency is estimated in this work.

  8. Experimental evaluation of the response of micro-channel plate detector to ions with 10s of MeV energies

    Science.gov (United States)

    Jeong, Tae Won; Singh, P. K.; Scullion, C.; Ahmed, H.; Kakolee, K. F.; Hadjisolomou, P.; Alejo, A.; Kar, S.; Borghesi, M.; Ter-Avetisyan, S.

    2016-08-01

    The absolute calibration of a microchannel plate (MCP) assembly using a Thomson spectrometer for laser-driven ion beams is described. In order to obtain the response of the whole detection system to the particles' impact, a slotted solid state nuclear track detector (CR-39) was installed in front of the MCP to record the ions simultaneously on both detectors. The response of the MCP (counts/particles) was measured for 5-58 MeV carbon ions and for protons in the energy range 2-17.3 MeV. The response of the MCP detector is non-trivial when the stopping range of particles becomes larger than the thickness of the detector. Protons with energies E ≳ 10 MeV are energetic enough that they can pass through the MCP detector. Quantitative analysis of the pits formed in CR-39 and the signal generated in the MCP allowed to determine the MCP response to particles in this energy range. Moreover, a theoretical model allows to predict the response of MCP at even higher proton energies. This suggests that in this regime the MCP response is a slowly decreasing function of energy, consistently with the decrease of the deposited energy. These calibration data will enable particle spectra to be obtained in absolute terms over a broad energy range.

  9. A coincidence-type ion-electron converter detector for low-energy protons

    International Nuclear Information System (INIS)

    Benka, O.; Weinzierl, P.; Dobrozemsky, R.; Stratowa, C.

    1981-04-01

    A coincidence type ion-electron converter detector has been developed and used - together with an electrostatic energy-analyser - for precision measurements of the energy distribution of recoil protons from free-neutron decay. The most important aspect of the development was, besides keeping the background below 0,2 counts/sec in the presence of a certain radiation background, to achieve a high and energy-independent counting probability for protons with energies between 100 and 1000 eV. With an acceleration voltage of about 25 kV and Al-foils (20 to 35 ug/cmsup2) as converter, we obtained counting efficiences of 70 to 85 percent. The design and performance of the detector system, employing six foils with different sensitive areas, are described and discussed in detail. (author)

  10. Heavy Ion Physics with the ATLAS Detector

    CERN Document Server

    Grabowska-Bold, Iwona

    2011-01-01

    The heavy-ion program at the Large Hadron Collider has been commenced in November 2010 by three experiments including ATLAS, a multipurpose detector originally constructed to study high-energy proton-proton collisions, which now also proved to be an excellent tool for studying nuclear interactions. In these proceedings results from the lead-lead run at $sqrt{s_{NN}}$=2.76 TeV based on the minimum-bias data sample are reviewed. In particular an observation of the centrality-dependent di-jet asymmetry is reported. Also a centrality-dependent suppression in the yield of $J/psi$ mesons decaying to $mu^+mu^-$ pairs is discussed along with an observation of the Z boson production. These evidences may bring new insight to the primordial universe where a hot, dense medium of quarks and gluons may have prevailed.

  11. Heavy Ion Physics with the ATLAS Detector

    CERN Document Server

    Grabowska-Bold, I

    2011-01-01

    The heavy-ion program at the Large Hadron Collider has started up in November 2010 by three experiments including ATLAS, a multipurpose detector originally constructed to study high-energy proton-proton collisions, which now turns out to be an excellent tool for studying nuclear interactions. In this talk first results from the lead-lead run at sqrt{s_{NN}}=2.76 TeV based on minimum bias data sample are reviewed. In particular an observation of the centrality-dependent di-jet asymmetry is reported. Also a centrality-dependent suppression in the yield of $J/Psi$ mesons decaying to $mu^+mu^-$ pairs is discussed along with an observation of the $Z$ boson production. These evidences may bring new insight to the primordial universe where a hot, dense medium of quarks and gluons may have prevailed.

  12. Recent progress of fast-ion loss detector project in Asian fusion experiments

    International Nuclear Information System (INIS)

    Isobe, Mitsutaka; Zhang Yipo; Kim, Jun-Young

    2013-01-01

    The A3 foresight program is accelerating close collaboration for fast-ion diagnostics development between Asian three countries. A recent big step in our activities is that the operation of fast-ion loss detector (FILD) on HL-2A has begun lately. The localized bright spot appeared on the scintillator screen while a high-energy neutral beam was tangentially co-injected. The design of FILD system on EAST is steadily ongoing. The diagnostics port available for our purpose was decided in March, 2013. For KSTAR, the FILD is working successfully. In order to understand observed beam-ion loss signals while the RMP coils are turned on, the LORBIT code has been improved recently to treat non-axisymmetric perturbed field due to RMP coils and discreteness of TF coils. (author)

  13. Semiconductor detectors for observation of multi-MeV protons and ions produced by lasers

    Czech Academy of Sciences Publication Activity Database

    Krása, Josef; Klir, D.; De Marco, Massimo; Cikhardt, J.; Velyhan, Andriy; Řezáč, Karel; Pfeifer, Miroslav; Krouský, Eduard; Ryć, L.; Dostál, Jan; Kaufman, Jan; Ullschmied, Jiří; Limpouch, J.

    2016-01-01

    Roč. 3, č. 1 (2016), 9-11 ISSN 2336-2626 R&D Projects: GA ČR GA16-07036S; GA MŠk EF15_008/0000162; GA MŠk(CZ) LD14089 Grant - others:ELI Beamlines(XE) CZ.02.1.01/0.0/0.0/15_008/0000162 Institutional support: RVO:68378271 ; RVO:61389021 Keywords : laser-accelerated ions * ion collectors * SiC detectors * similarity relations * electromagnetic pulse Subject RIV: BL - Plasma and Gas Discharge Physics

  14. High-performance DIRC detector for the future Electron Ion Collider experiment

    Science.gov (United States)

    Kalicy, G.; Allison, L.; Cao, T.; Dzhygadlo, R.; Hartlove, T.; Horn, T.; Hyde, C.; Ilieva, Y.; Nadel-Turonski, P.; Park, K.; Peters, K.; Schwarz, C.; Schwiening, J.; Stevens, J.; Xi, W.; Zorn, C.

    2018-04-01

    Excellent particle identification (PID) is an essential requirement for a future Electron-Ion Collider (EIC) detector. Identification of the hadrons in the final state is critical to study how different quark flavors contribute to nucleon properties. A detector based on the Detection of Internally Reflected Cherenkov light (DIRC) principle, with a radial size of only a few cm, is a perfect solution for those requirements. The R&D process performed by the EIC PID consortium (eRD14) is focused on designing a high-performance DIRC that would extend the momentum coverage well beyond the state-of-the-art, allowing 3 standard deviations or more separation of π/K up to 6 GeV/c, e/π up to 1.8 GeV/c, and p/K up to 10 GeV/c. A key component to reach such a performance is a special 3-layer compound lens. This article describes the status of the High-Performance DIRC R&D for the EIC detector, with a focus on the detailed Monte Carlo simulation results and performance tests of the 3-layer lens.

  15. Ion beam induced charge and cathodoluminescence imaging of response uniformity of CVD diamond radiation detectors

    CERN Document Server

    Sellin, P J; Galbiati, A; Maghrabi, M; Townsend, P D

    2002-01-01

    The uniformity of response of CVD diamond radiation detectors produced from high quality diamond film, with crystallite dimensions of >100 mu m, has been studied using ion beam induced charge imaging. A micron-resolution scanning alpha particle beam was used to produce maps of pulse height response across the device. The detectors were fabricated with a single-sided coplanar electrode geometry to maximise their sensitivity to the surface region of the diamond film where the diamond crystallites are highly ordered. High resolution ion beam induced charge images of single crystallites were acquired that demonstrate variations in intra-crystallite charge transport and the termination of charge transport at the crystallite boundaries. Cathodoluminescence imaging of the same crystallites shows an inverse correlation between the density of radiative centres and regions of good charge transport.

  16. Long-range alpha detector

    International Nuclear Information System (INIS)

    MacArthur, D.W.; McAtee, J.L.

    1991-01-01

    Historically, alpha-particle and alpha-contamination detectors have been limited by the very short range of alpha particles in air and by relatively poor sensitivity even if the particles are intercepted. Alpha detectors have had to be operated in a vacuum or in close proximity to the source if reasonable efficiency is desired. Alpha particles interact with the ambient air, producing ionization in the air at the rate of ∼30,000 ion pairs per mega-electron-volt of alpha energy. These charges can be transported over significant distances (several meters) in a moving current of air generated by a small fan. An ion chamber located in front of the fan measures the current carried by the moving ions. The long-range alpha detector (LRAD) offers several advantages over more traditional alpha detectors. First and foremost, it can operate efficiently even if the contamination is not easily accessible. Second, ions generated by contamination in crevices and other unmonitorable locations can be detected if the airflow penetrates those areas. Third, all of the contamination on a large surface will generate ions that can be detected in a single detector; hence, the detector's sensitivity to distributed sources is not limited by the size of the probe. Finally, a simple ion chamber can detect very small electric currents, making this technique potentially quite sensitive

  17. Quasilinear ion distribution function during first harmonic ion cyclotron heating

    International Nuclear Information System (INIS)

    Brambilla, M.

    1993-12-01

    The quasilinear modification of the ion distribution function during first harmonic ion cyclotron (FHIC) heating is investigated both with a simple already well established analytic one-dimensional approach, and with a new two dimensional steady state solver of the quasilinear kinetic equation, SSFPQL. By accepting to disregard the effects of ion trapping in banana orbits, but including finite Larmor radius effects, the latter code has been made much faster than full surface-averaged codes; yet it can provide most of the relevant information on the suprathermal ion tail produced by this heating method. With SSFPQL we confirm that the one-dimensional model gives fair approximations for global properties of the distribution function, such as the average energy content of the tail and the fusion reactivity. On the other hand the tail is found to be very anisotropic, the increase of the parallel effective temperature being a small fraction of the total energy increase. Information on the anisotropy is essential to study the feedback of the fast ion tail on wave propagation and absorption, which is quite sensitive to the distribution of parallel velocities. The insight gained in the derivation and discussion of this model can be used to build a selfconsistent description of this heating scenario, whose implementation requires only a reasonable numerical effort. (orig.)

  18. Experimental evaluation of the response of micro-channel plate detector to ions with 10s of MeV energies

    International Nuclear Information System (INIS)

    Jeong, Tae Won; Ter-Avetisyan, S.; Singh, P. K.; Kakolee, K. F.; Scullion, C.; Ahmed, H.; Hadjisolomou, P.; Alejo, A.; Kar, S.; Borghesi, M.

    2016-01-01

    The absolute calibration of a microchannel plate (MCP) assembly using a Thomson spectrometer for laser-driven ion beams is described. In order to obtain the response of the whole detection system to the particles’ impact, a slotted solid state nuclear track detector (CR-39) was installed in front of the MCP to record the ions simultaneously on both detectors. The response of the MCP (counts/particles) was measured for 5–58 MeV carbon ions and for protons in the energy range 2–17.3 MeV. The response of the MCP detector is non-trivial when the stopping range of particles becomes larger than the thickness of the detector. Protons with energies E ≳ 10 MeV are energetic enough that they can pass through the MCP detector. Quantitative analysis of the pits formed in CR-39 and the signal generated in the MCP allowed to determine the MCP response to particles in this energy range. Moreover, a theoretical model allows to predict the response of MCP at even higher proton energies. This suggests that in this regime the MCP response is a slowly decreasing function of energy, consistently with the decrease of the deposited energy. These calibration data will enable particle spectra to be obtained in absolute terms over a broad energy range.

  19. Experimental evaluation of the response of micro-channel plate detector to ions with 10s of MeV energies

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Tae Won; Ter-Avetisyan, S. [Center for Relativistic Laser Science, Institute of Basic Science (IBS), Gwangju 61005 (Korea, Republic of); Department of Physics and Photon Science, Gwangju Institute of Science and Technology (GIST), Gwangju 61005 (Korea, Republic of); Singh, P. K.; Kakolee, K. F. [Center for Relativistic Laser Science, Institute of Basic Science (IBS), Gwangju 61005 (Korea, Republic of); Scullion, C.; Ahmed, H.; Hadjisolomou, P.; Alejo, A.; Kar, S.; Borghesi, M. [School of Mathematics and Physics, The Queen’s University of Belfast, Belfast BT7 1NN (United Kingdom)

    2016-08-15

    The absolute calibration of a microchannel plate (MCP) assembly using a Thomson spectrometer for laser-driven ion beams is described. In order to obtain the response of the whole detection system to the particles’ impact, a slotted solid state nuclear track detector (CR-39) was installed in front of the MCP to record the ions simultaneously on both detectors. The response of the MCP (counts/particles) was measured for 5–58 MeV carbon ions and for protons in the energy range 2–17.3 MeV. The response of the MCP detector is non-trivial when the stopping range of particles becomes larger than the thickness of the detector. Protons with energies E ≳ 10 MeV are energetic enough that they can pass through the MCP detector. Quantitative analysis of the pits formed in CR-39 and the signal generated in the MCP allowed to determine the MCP response to particles in this energy range. Moreover, a theoretical model allows to predict the response of MCP at even higher proton energies. This suggests that in this regime the MCP response is a slowly decreasing function of energy, consistently with the decrease of the deposited energy. These calibration data will enable particle spectra to be obtained in absolute terms over a broad energy range.

  20. Description of current pulses induced by heavy ions in silicon detectors (II)

    Energy Technology Data Exchange (ETDEWEB)

    Hamrita, H. [Institut de Physique Nucleaire, CNRS/IN2P3, Universite Paris-Sud 11, F-91406 Orsay Cedex (France); CEA, LIST, Laboratoire Capteurs et Architectures Electroniques, F-91191 Gif-sur-Yvette Cedex (France); Parlog, M. [LPC, CNRS/IN2P3, ENSICAEN, Universite de Caen, F-14050 Caen Cedex (France); National Institute for Physics and Nuclear Engineering, RO-76900 Bucharest-Magurele (Romania); Borderie, B., E-mail: borderie@ipno.in2p3.fr [Institut de Physique Nucleaire, CNRS/IN2P3, Universite Paris-Sud 11, F-91406 Orsay Cedex (France); Lavergne, L. [Institut de Physique Nucleaire, CNRS/IN2P3, Universite Paris-Sud 11, F-91406 Orsay Cedex (France); Le Neindre, N. [Institut de Physique Nucleaire, CNRS/IN2P3, Universite Paris-Sud 11, F-91406 Orsay Cedex (France); LPC, CNRS/IN2P3, ENSICAEN, Universite de Caen, F-14050 Caen Cedex (France); Rivet, M.F.; Barbey, S. [Institut de Physique Nucleaire, CNRS/IN2P3, Universite Paris-Sud 11, F-91406 Orsay Cedex (France); Bougault, R. [LPC, CNRS/IN2P3, ENSICAEN, Universite de Caen, F-14050 Caen Cedex (France); Chabot, M. [Inst. de Physique Nucleaire, CNRS/IN2P3, Universite Paris-Sud 11, F-91406 Orsay Cedex (France); Chbihi, A. [GANIL (DSM-CEA/CNRS/IN2P3), F-14076 Caen Cedex (France); Cussol, D. [LPC, CNRS/IN2P3, ENSICAEN, Univ. de Caen, F-14050 Caen Cedex (France); Oliveira Santos, F. de [GANIL (DSM-CEA/CNRS/IN2P3), F-14076 Caen Cedex (France); Edelbruck, P. [Inst. de Physique Nucleaire, CNRS/IN2P3, Univ. Paris-Sud 11, F-91406 Orsay Cedex (France); Frankland, J.D. [GANIL (DSM-CEA/CNRS/IN2P3), F-14076 Caen Cedex (France); Galichet, E. [Inst. de Physique Nucleaire, CNRS/IN2P3, Univ. Paris-Sud 11, F-91406 Orsay Cedex (France); Conservatoire National des Arts et Metier, F-75141 Paris Cedex 03 (France); Guinet, D.; Lautesse, Ph. [Inst. de Physique Nucleaire, CNRS/IN2P3, Univ.e Claude Bernard Lyon I, F-69622 Villeurbanne Cedex (France); Lopez, O. [LPC, CNRS/IN2P3, ENSICAEN, Univ. de Caen, F-14050 Caen Cedex (France)

    2011-06-21

    Current pulses induced in a silicon detector by 10 different heavy ion species at known energies around 10 A MeV have been sampled in time at high frequency. Their individual average shapes are quite well reproduced by a fit procedure based on our recent charge carrier collection treatment which considers the progressive extraction of the electrons and holes from the high carrier density zone along the ionizing particle track. This region is assumed to present a supplementary dielectric polarization and consequently a disturbed electric field. The influence of the nature of the heavy ion on the values of the three fit parameters is analyzed.

  1. Study of profile control and suprathermal electron production with lower hybrid waves

    International Nuclear Information System (INIS)

    Soeldner, F.X.; Brambilla, M.; Leuterer, F.; Muenich, M.

    1986-05-01

    In this study the coupling of LH waves to suprathermal electrons, the LH current drive efficiency and the mechanism for sawtooth stabilisation will be discussed. A wide data base has been obtained by the LH experiments on Alcator C, ASDEX, FT; JFT-2M, JIPPT-IIU, Petula, PLT, Versator, WT II during the last years and important aspects as the scaling of global current drive efficiency are satisfactorily described by theory. We mainly rely here on experimental results from ASDEX and comparison with theoretical calculations by Fisch and Karney. (orig.)

  2. Ion detection in mass spectrometry

    International Nuclear Information System (INIS)

    Bolbach, Gerard

    2016-03-01

    This course aims at providing some elements for a better understanding of ion detectors used in mass spectrometers, of their operations, and of their limitations. A first part addresses the functions and properties of an ideal detector, how to detect ions in gas phase, and particle detectors and ion detectors used in mass spectrometry. The second part proposes an overview of currently used detectors with respect to their operation principle: detection from the ion charge (Faraday cylinder), detection by inductive effects (FTICR, Fourier Transform Ion Cyclotron Resonance), and detection by secondary electron emission. The third part discusses the specificities of secondary electron emission. The fourth one addresses operating modes and parameters related to detectors. The sixth part proposes a prospective view on future detectors by addressing the following issues: cryo-detector, inductive effect and charge detectors, ion detection and nano materials

  3. Applications of solid-state nuclear track detectors (SSNTDs) for fast ion and fusion reaction product measurements in TEXTOR experiments

    Energy Technology Data Exchange (ETDEWEB)

    Szydlowski, A.; Malinowski, K.; Malinowska, A. [Association EURTOM-IPPLM Warsaw, The Andrzej Soltan Institute for Nuclear Studies, 05-400 Otwock-Swierk (Poland); Wassenhove, G. Van [EURATOM-Belgium State Association, LPP, ERM/KMS, Trilateral Euregio Cluster, B-1000 Brussels (Belgium); Schweer, B. [Association EURATOM-FZJ, Institutte of Plasma Physicx, Juelich (Germany)

    2011-07-01

    Full text of publication follows: The paper reports on measurements of fusion reaction protons which were performed on TEXTOR facility in January 2009. The basic experimental scheme was similar to that applied in the previous measurements [1, 2]. The main experimental tool equipment was a small ion pinhole camera which was equipped with a PM-355 detector sample and was attached to a water cooled manipulator. The camera was placed below the plasma ring in the direction of ion drifts, at a distance of 4.4 cm from LCFS. However, in the described experiment it was aligned at an angle to the mayor TEXTOR radius (contrary to previous experiments), so that the input pinhole was oriented first at {gamma} = 45 degrees (shots 108799 - 108818) and then {gamma} = 600 (shots 108832 - 108847). The discharges were executed with one neutral beam of the total power 0.6 - 1.0 MW. In the first series (Nos 108799 - 108818) the plasma was additionally heated by ICRH of frequency 38 MHz. The irradiated detector samples were subjected to the same interrupted etching procedure as the samples used in the CR-39/PM-355 detector calibration measurements [1, 2]. After that, track density distributions and track diameter histograms were measured under an optical microscope. By the use of the calibration curves, it was possible to distinguish craters produced by protons from other craters and to convert the obtained histograms into proton energy spectra. The craters induced by lower energy ions appeared to be concentrated in narrower areas, whereas higher energy ions were registered in a more diffused detector fields. The paper shows again that the CR-39/PM-355 detector is an useful diagnostic tool for tokamak experiments, for measurement of charged ions. References: [1] A. Szydlowski, A. Malinowska, M. Jaskola, A. Korman, M.J. Sadowski, G. Van Wassenhove, B. Schweer and the TEXTOR team, A. Galkowski, 'Application of Solid State Nuclear Track Detectors in TEXTOR Experiment for Measurements

  4. Tests of Bubble Damage Detectors in a Heavy Ion Beam from the SPS

    CERN Multimedia

    2002-01-01

    This experiment is designed to investigate the properties of a bubble damage polymer (BDP) using ion beams from the SPS. These polymers are already used commercially for making neutron and gamma-ray dosimeters. \\\\ \\\\ An attractive feature of BDP detectors is the ability to ``design'' a material to have a particular dE/dx threshold which can be used to detect such objects as monopoles and heavy ions as well as relativistic, singly charged tracks originating f particle interactions. \\\\ \\\\ The BDP detector is a polymer which holds droplets of super-heated liquid in suspension. The droplet size is typically a few microns and the droplet density is normally between 10|5 and 10|7 droplets/cm|3. The passage of a particle with a dE/dx exceeding the threshold of the material will cause the droplets with a sufficiently s parameter to change state, giving rise to bubbles. The dE/dx threshold of the BDP varies with pressure and temperature. The growth of bubbles in the bubble trail is limited by the polymer matrix and th...

  5. Pulse height defect in ion implanted silicon detector for heavy ions with Z=6-28 in the energy range ∼ 0.25-2.5 MeV/u

    International Nuclear Information System (INIS)

    Diwan, P.K.; Sharma, V.; Shyam Kumar; Avasthi, D.K.

    2005-01-01

    The response of ion implanted silicon detector has been studied for heavy ions with Z= 6-28 in the energy range ∼ 0.25-2.5 MeV/u utilizing the 15UD Pelletron Accelerator facility at Nuclear Science Centre, New Delhi, India. The variation of pulse height in ion implanted silicon detector with projectile's atomic number and its energy have been investigated. It has been observed that pulse height-energy calibration for a given projectile is described well by a linear relationship indicating no pulse height defect with the variation in energy for specific Z projectile. Pulse height defect has been found to increase with increasing projectile atomic number. The mean slope of the collected charge signal versus projectile energy depends significantly on the atomic number of the projectile. (author)

  6. Generation of suprathermal electrons during plasma current startup by lower hybrid waves in a tokamak

    International Nuclear Information System (INIS)

    Ohkubo, K.; Toi, K.; Kawahata, K.

    1984-10-01

    Suprathermal electrons which carry a seed current are generated by non-resonant parametric decay instability during initial phase of lower hybrid current startup in the JIPP T-IIU tokamak. From the numerical analysis, it is found that parametrically excited lower hybrid waves at lower side band can bridge the spectral gap between the thermal velocity and the low velocity end in the pump power spectrum. (author)

  7. Department of Radiation Detectors: Overview

    International Nuclear Information System (INIS)

    Piekoszewski, J.

    1998-01-01

    (full text) Work carried out in 1997 in the Department of Radiation Detectors concentrated on three subjects: (i) Semiconductor Detectors (ii) X-ray Tube Generators (iii) Material Modification using Ion and Plasma Beams. Semiconductor detectors: Semiconductor detectors of ionizing radiation are among the basic tools utilized in such fields of research and industry as nuclear physics, high energy physics, medical (oncology) radiotherapy, radiological protection, environmental monitoring, energy dispersive X-ray fluorescence non-destructive analysis of chemical composition, nuclear power industry. The Department all objectives are: - search for new types of detectors, - adapting modern technologies (especially of industrial microelectronics) to detector manufacturing, - producing unique detectors tailored for physics experiments, - manufacturing standard detectors for radiation measuring instruments, - scientific development of the staff. These 1997 objectives were accomplished particularly by: - research on unique detectors for nuclear physics (e.g. transmission type Si(Li) detectors with extremely thin entrance and exit window), - development of technology of high-resistivity (HRSi) silicon detectors and thermoelectric cooling systems (KBN grant), - study of the applicability of industrial planar technology in producing detectors, - manufacturing detectors developed in previous years, re-generating and servicing customer detectors of various origin. In accomplishing of the above, the Department cooperated with interested groups of physicists from our Institute (P-I and P-II Departments), Warsaw University, Warsaw Heavy Ion Laboratory and with some technology Institutes based in Warsaw (ITME, ITE). Some detectors and services have been delivered to customers on a commercial basis. X-Rat tube generators: The Department conducts research on design and technology of producing X-ray generators based on X-ray tubes of special construction. In 1997, work on a special

  8. Dielectronic recombination experiments with tungsten ions at the test storage ring and development of a single-particle detector at the cryogenic storage ring

    International Nuclear Information System (INIS)

    Spruck, Kaija

    2015-05-01

    This work is about electron-ion collision experiments at the ion storage rings of the Max Planck Institute for Nuclear Physics in Heidelberg. Absolute recombination rate coefficients of highly-charged tungsten ions featuring an open 4-f-shell structure have been measured at the heavy-ion storage ring TSR. The resulting plasma rate coefficients have been used to probe the significance of newly developed theoretical approaches. Plasma rate coefficients of highly-charged tungsten ions are in particular interesting for the development of plasma models for nuclear fusion reactors, since tungsten is a foreseeable impurity in the fusion plasma. In the relevant temperature range, the experimental results exceed the theoretical data used so far by up to a factor of 10, showing the need for more reliable theoretical calculations. Furthermore, based on the design of the detectors which have been used in the experiments at TSR, a movable single-particle detector for electron-ion recombination studies at the cryogenic storage ring CSR has been developed and installed within the scope of this work. The device has been designed specifically to meet the requirements of the CSR regarding low ion energies and cryogenic ambient temperature conditions. In a series of experiments, the detector was carefully characterised and successfully tested for its compatibility with these requirements. The detector was part of the infrastructure used for the room-temperature commissioning of CSR (2014) and is currently operated as a single-particle counter during the first cryogenic operation of CSR in 2015.

  9. Dielectronic recombination experiments with tungsten ions at the test storage ring and development of a single-particle detector at the cryogenic storage ring

    Energy Technology Data Exchange (ETDEWEB)

    Spruck, Kaija

    2015-05-15

    This work is about electron-ion collision experiments at the ion storage rings of the Max Planck Institute for Nuclear Physics in Heidelberg. Absolute recombination rate coefficients of highly-charged tungsten ions featuring an open 4-f-shell structure have been measured at the heavy-ion storage ring TSR. The resulting plasma rate coefficients have been used to probe the significance of newly developed theoretical approaches. Plasma rate coefficients of highly-charged tungsten ions are in particular interesting for the development of plasma models for nuclear fusion reactors, since tungsten is a foreseeable impurity in the fusion plasma. In the relevant temperature range, the experimental results exceed the theoretical data used so far by up to a factor of 10, showing the need for more reliable theoretical calculations. Furthermore, based on the design of the detectors which have been used in the experiments at TSR, a movable single-particle detector for electron-ion recombination studies at the cryogenic storage ring CSR has been developed and installed within the scope of this work. The device has been designed specifically to meet the requirements of the CSR regarding low ion energies and cryogenic ambient temperature conditions. In a series of experiments, the detector was carefully characterised and successfully tested for its compatibility with these requirements. The detector was part of the infrastructure used for the room-temperature commissioning of CSR (2014) and is currently operated as a single-particle counter during the first cryogenic operation of CSR in 2015.

  10. Influence of damage caused by Kr ions and neutrons on electrical properties of silicon detectors

    International Nuclear Information System (INIS)

    Croitoru, N.; Gubbini, E.; Rancoita, P.G.; Rattaggi, M.; Seidman, A.

    1999-01-01

    In this paper, new measurements of physical properties of high-resistivity silicon, used in high-energy detectors, are presented. The obtained data contribute to the understanding of the causes which damage the 2electronic characteristics of the detection systems under irradiation of neutrons and ionized particles (Kr). The Hall effect coefficient (R H ) and resistivity (ρ) measurements as a function of temperature (T), for non-irradiated and irradiated by neutrons and Kr ions, were performed. The measurements of the Hall coefficient and resistivity of non-irradiated samples and irradiated at neutron fluences (PHI≤9.9x10 10 n/cm 2 ) and Kr (PHI≤7.5x10 8 Kr/cm 2 ), have shown that the obtained characteristics, R H (T) and ρ(T), are of the same shape as those known for a silicon single crystal. A slight difference of the slope of ln ρ∼ln T, for neutron- and a large difference for Kr ion irradiation as compared with that of non-irradiated samples, was observed. On increasing the irradiation to PHI larger than the value indicated above, for neutrons and Kr ions, important changes in the physical properties were observed. The resistivity increases with increasing PHI, up to a value of the same order with intrinsic silicon (ρ∼10 5 Ω cm), for both neutron and Kr ion irradiation. The values of R H increase with increasing PHI up to a fluence, for which a change of sign, from negative to positive, occurs. The variation of values of R H and ρ as a function of PHI, for neutrons and Kr ions, is similar, but the characteristics R H (PHI) and ρ(PHI), are displaced. Therefore, larger values of PHI are needed in order to obtain the same values of ρ as those for Kr ion irradiation. The dependence on T of electrical parameters of samples, irradiated at PHI≥9.9x10 10 n/cm 2 (neutrons) and PHI≥7.5x10 8 Kr/cm 3 (ions), cannot be explained, considering the usual theoretical relations. The results, obtained in these experiments, have shown a change of mechanism of

  11. Average energetic ion flux variations associated with geomagnetic activity from EPIC/STICS on Geotail

    Science.gov (United States)

    Christon, S. P.; Gloeckler, G.; Eastman, T. E.; McEntire, R. W.; Roelef, E. C.; Lui, A. T. Y.; Williams, D. J.; Frank, L. A.; Paterson, W. R.; Kokubun, S.; hide

    1996-01-01

    The magnetotail ion flux measurements from the Geotail spacecraft are analyzed both with and without the application of selection criteria that identify the plasma regime in which an observation is obtained. The different results are compared with each other. The initial results on the changes of energetic ion flux and composition correlated to average substorm activity in different magnetotail plasma regimes are discussed. The energetic ions are measured using the energetic particles and ion composition (EPIC) experiment and the suprathermal ion composition spectrometer (STICS). The plasma, wave and field instruments of the Geotail satellite were used to identify the principle magnetotail plasma regimes of plasma sheet, lobe, and magnetospheric boundary layer, as well as the magnetosheath and solar wind. Energetic O and H ions were observed in all the plasma regimes.

  12. SUPRATHERMAL ELECTRONS IN TITAN’S SUNLIT IONOSPHERE: MODEL–OBSERVATION COMPARISONS

    Energy Technology Data Exchange (ETDEWEB)

    Vigren, E.; Edberg, N. J. T.; Wahlund, J.-E. [Swedish Institute of Space Physics, Uppsala (Sweden); Galand, M.; Sagnières, L. [Department of Physics, Imperial College London, London SW7 2AZ (United Kingdom); Wellbrock, A.; Coates, A. J. [Mullard Space Science Laboratory, University College London, Dorking, Surrey RH5 6NT (United Kingdom); Cui, J. [National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100012 (China); Lavvas, P. [Université Reims Champagne-Ardenne, Reims (France); Snowden, D. [Department of Physics, Central Washington University, Ellensburg, WA 98926 (United States); Vuitton, V., E-mail: erik.vigren@irfu.se [Univ. Grenoble Alpes, CNRS, IPAG, Grenoble (France)

    2016-08-01

    The dayside ionosphere of the Saturnian satellite Titan is generated mainly from photoionization of N{sub 2} and CH{sub 4}. We compare model-derived suprathermal electron intensities with spectra measured by the Cassini Plasma Spectrometer/Electron Spectrometer (CAPS/ELS) in Titan's sunlit ionosphere (altitudes of 970–1250 km) focusing on the T40, T41, T42, and T48 Titan flybys by the Cassini spacecraft. The model accounts only for photoelectrons and associated secondary electrons, with a main input being the impinging solar EUV spectra as measured by the Thermosphere Ionosphere Mesosphere Energy and Dynamics/Solar EUV Experiment and extrapolated to Saturn. Associated electron-impact electron production rates have been derived from ambient number densities of N{sub 2} and CH{sub 4} (measured by the Ion Neutral Mass Spectrometer/Closed Source Neutral mode) and related energy-dependent electron-impact ionization cross sections. When integrating up to electron energies of 60 eV, covering the bulk of the photoelectrons, the model-based values exceed the observationally based values typically by factors of ∼3 ± 1. This finding is possibly related to current difficulties in accurately reproducing the observed electron number densities in Titan's dayside ionosphere. We compare the utilized dayside CAPS/ELS spectra with ones measured in Titan's nightside ionosphere during the T55–T59 flybys. The investigated nightside locations were associated with higher fluxes of high-energy (>100 eV) electrons than the dayside locations. As expected, for similar neutral number densities, electrons with energies <60 eV give a higher relative contribution to the total electron-impact ionization rates on the dayside (due to the contribution from photoelectrons) than on the nightside.

  13. Calorimetric Low-Temperature Detectors for X-Ray Spectroscopy on Trapped Highly-Charged Heavy Ions

    Science.gov (United States)

    Kilbourne, Caroline; Kraft-Bermuth, S.; Andrianov, V.; Bleile, A.; Echler, A.; Egelhof, P.; Ilieva, S.; Kilbourne, C.; McCammon, D.

    2012-01-01

    The application of Calorimetric Low-Temperature Detectors (CLTDs) has been proposed at the Heavy-Ion TRAP facility HITRAP which is currently being installed at the Helmholtz Research Center for Heavy Ion Research GSI. This cold ion trap setup will allow the investigation of X-rays from ions practically at rest, for which the excellent energy resolution of CLTDs can be used to its full advantage. However, the relatively low intensities at HITRAP demand larger solid angles and an optimized cryogenic setup. The influence of external magnetic fields has to be taken into account. CLTDs will also be a substantial part of the instrumental equipment at the future Facility for Antiproton and Heavy Ion Research (FAIR), for which a wide variety of high-precision X-ray spectroscopy experiments has been proposed. This contribution will give an overview on the chances and challenges for the application of CLTDs at HITRAP as well as perspectives for future experiments at the FAIR facility.

  14. Diogene, a 4π detector for the heavy ion physics with Saturne

    International Nuclear Information System (INIS)

    Alard, J.P.; Augerat, J.; Babinet, R.

    A 4π-detection set up is presently being built around the Saturne II facility, to study central collisions between high energy heavy ions. This set up is essentially composed of a cylindrical drift chamber, triggered by a 30-scintillators multiplicity filter. A schematic description of the detector is given first. Then the present status of the project is presented, at last some progresses on track reconstruction technique with simulated events are given [fr

  15. Measurement and modelling of suprathermal electron bursts generated in front of a lower hybrid antenna

    Czech Academy of Sciences Publication Activity Database

    Gunn, J. P.; Fuchs, Vladimír; Petržílka, Václav; Ekedahl, A.; Fedorczak, N.; Goniche, M.; Hillairet, J.

    2016-01-01

    Roč. 56, č. 3 (2016), č. článku 036004. ISSN 0029-5515 R&D Projects: GA MŠk(CZ) LM2011021 Institutional support: RVO:61389021 Keywords : lower hybrid * scrape off layer * SOL turbulence * Landau damping * suprathermal electrons Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: Fluids and plasma physics (including surface physics) Impact factor: 3.307, year: 2016 http://iopscience.iop.org/article/10.1088/0029-5515/56/3/036004

  16. Development of slew-rate-limited time-over-threshold (ToT) ASIC for a multi-channel silicon-based ion detector

    Science.gov (United States)

    Uenomachi, M.; Orita, T.; Shimazoe, K.; Takahashi, H.; Ikeda, H.; Tsujita, K.; Sekiba, D.

    2018-01-01

    High-resolution Elastic Recoil Detection Analysis (HERDA), which consists of a 90o sector magnetic spectrometer and a position-sensitive detector (PSD), is a method of quantitative hydrogen analysis. In order to increase sensitivity, a HERDA system using a multi-channel silicon-based ion detector has been developed. Here, as a parallel and fast readout circuit from a multi-channel silicon-based ion detector, a slew-rate-limited time-over-threshold (ToT) application-specific integrated circuit (ASIC) was designed, and a new slew-rate-limited ToT method is proposed. The designed ASIC has 48 channels and each channel consists of a preamplifier, a slew-rate-limited shaping amplifier, which makes ToT response linear, and a comparator. The measured equivalent noise charges (ENCs) of the preamplifier, the shaper, and the ToT on no detector capacitance were 253±21, 343±46, and 560±56 electrons RMS, respectively. The spectra from a 241Am source measured using a slew-rate-limited ToT ASIC are also reported.

  17. Influence of damage caused by Kr ions and neutrons on electrical properties of silicon detectors

    CERN Document Server

    Croitoru, N; Rancoita, P G; Rattaggi, M; Seidman, A

    1999-01-01

    In this paper, new measurements of physical properties of high-resistivity silicon, used in high-energy detectors, are presented. The obtained data contribute to the understanding of the causes which damage the 2electronic characteristics of the detection systems under irradiation of neutrons and ionized particles (Kr). The Hall effect coefficient (R sub H) and resistivity (rho) measurements as a function of temperature (T), for non-irradiated and irradiated by neutrons and Kr ions, were performed. The measurements of the Hall coefficient and resistivity of non-irradiated samples and irradiated at neutron fluences (PHI=9.9x10 sup 1 sup 0 n/cm sup 2 (neutrons) and PHI>=7.5x10 sup 8 Kr/cm sup 3 (ions), cannot be explained, considering the usual theoretical relations. The results, obtained in these experiments, have shown a change of mechanism of conduction due to the damaged regions, where localized levels are created, which are the main cause of the deviation of the electrical characteristics of the detectors ...

  18. A combined segmented anode gas ionization chamber and time-of-flight detector for heavy ion elastic recoil detection analysis

    Science.gov (United States)

    Ström, Petter; Petersson, Per; Rubel, Marek; Possnert, Göran

    2016-10-01

    A dedicated detector system for heavy ion elastic recoil detection analysis at the Tandem Laboratory of Uppsala University is presented. Benefits of combining a time-of-flight measurement with a segmented anode gas ionization chamber are demonstrated. The capability of ion species identification is improved with the present system, compared to that obtained when using a single solid state silicon detector for the full ion energy signal. The system enables separation of light elements, up to Neon, based on atomic number while signals from heavy elements such as molybdenum and tungsten are separated based on mass, to a sample depth on the order of 1 μm. The performance of the system is discussed and a selection of material analysis applications is given. Plasma-facing materials from fusion experiments, in particular metal mirrors, are used as a main example for the discussion. Marker experiments using nitrogen-15 or oxygen-18 are specific cases for which the described improved species separation and sensitivity are required. Resilience to radiation damage and significantly improved energy resolution for heavy elements at low energies are additional benefits of the gas ionization chamber over a solid state detector based system.

  19. Ion temperature measurement of indirectly-driven implosions using a geometry-compensated neutron time-of-flight detector

    International Nuclear Information System (INIS)

    Murphy, T.J.; Lerche, R.A.; Bennett, C.; Howe, G.

    1994-05-01

    A geometry-compensated neutron time-of-flight detector has been constructed and used on Nova to measure ion temperatures from indirectly-driven implosions with yields between 2.5 and 5 x 10 9 DD neutrons. The detector, which has an estimated response time of 250 ps, was located 150 cm from the targets. Due to the long decay time of the scintillator, the time-of-flight signal must be unfolded from the measured detector signal. Several methods for determining the width of the neutron energy spectrum from the data have been developed and give similar results. Scattered x rays continue to be a problem for low yield shots, but should be brought under control with adequate shielding

  20. Ion-temperature measurement of indirectly driven implosions using a geometry-compensated neutron time-of-flight detector

    International Nuclear Information System (INIS)

    Murphy, T.J.; Lerche, R.A.; Bennett, C.; Howe, G.

    1995-01-01

    A geometry-compensated neutron time-of-flight detector has been constructed and used on Nova to measure ion temperatures from indirectly driven implosions with yields between 2.5 and 5x10 9 DD neutrons. The detector, which has an estimated respond time of 250 ps, was located 150 cm from the targets. Due to the long decay time of the scintillator, the time-of-flight signal must be unfolded from the measured detector signal. Several methods for determining the width of the neutron energy spectrum from the data have been developed and give similar results. Scattered x rays continue to be a problem for low yield shots, but should be brought under control with adequate shielding

  1. Research of high energy radioactivity identification detector

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Kyun; Lee, Yong Bum; Hwang, Jong Sun; Choi, Seok Ki

    1998-07-01

    {Delta} {Epsilon}-{Epsilon} telescope high radioactivity detector was designed, fabricated, and tested at the 35 MeV proton energy. We developed the computer code to calculate the energy loss of projectile ions in the matter. Using the code, we designed and fabricated a detector to measure 15-50 MeV protons. The detector was successfully tested to measure the energy of protons and deuterons and to identify the ions. In future, we would like to extend the present result to the development of a higher energy proton detector and a heavy ion detector. (author). 10 refs., 3 tabs., 14 figs

  2. Energetic Nitrogen Ions within the Inner Magnetosphere of Saturn

    Science.gov (United States)

    Sittler, E. C.; Johnson, R. E.; Richardson, J. D.; Jurac, S.; Moore, M.; Cooper, J. F.; Mauk, B. H.; Smith, H. T.; Michael, M.; Paranicus, C.; Armstrong, T. P.; Tsurutani, B.; Connerney, J. E. P.

    2003-05-01

    Titan's interaction with Saturn's magnetosphere will result in the energetic ejection of atomic nitrogen atoms into Saturn's magnetosphere due to dissociation of N2 by electrons, ions, and UV photons. The ejection of N atoms into Saturn's magnetosphere will form a nitrogen torus around Saturn with mean density of about 4 atoms/cm3 with source strength of 4.5x1025 atoms/sec. These nitrogen atoms are ionized by photoionization, electron impact ionization and charge exchange reactions producing an N+ torus of 1-4 keV suprathermal ions centered on Titan's orbital position. We will show Voyager plasma observations that demonstrate presence of a suprathermal ion component within Saturn's outer magnetosphere. The Voyager LECP data also reported the presence of inward diffusing energetic ions from the outer magnetosphere of Saturn, which could have an N+ contribution. If so, when one conserves the first and second adiabatic invariant the N+ ions will have energies in excess of 100 keV at Dione's L shell and greater than 400 keV at Enceladus' L shell. Energetic charged particle radial diffusion coefficients are also used to constrain the model results. But, one must also consider the solar wind as another important source of keV ions, in the form of protons and alpha particles, for Saturn's outer magnetosphere. Initial estimates indicate that a solar wind source could dominate in the outer magnetosphere, but various required parameters for this estimate are highly uncertain and will have to await Cassini results for confirmation. We show that satellite sweeping and charged particle precipitation within the middle and outer magnetosphere will tend to enrich N+ ions relative to protons within Saturn's inner magnetosphere as they diffuse radially inward for radial diffusion coefficients that do not violate observations. Charge exchange reactions within the inner magnetosphere can be an important loss mechanism for O+ ions, but to a lesser degree for N+ ions. Initial LECP

  3. A novel ion imager for secondary ion mass spectrometry

    International Nuclear Information System (INIS)

    Matsumoto, Kazuya; Miyata, Kenji; Nakamura, Tsutomu

    1993-01-01

    This paper describes a new area detector for secondary ion mass spectrometry (SIMS) ion microscope, and its performance. The operational principle is based on detecting the change in potential of a floating photodiode caused by the ion-induced secondary-electron emission and the incoming ion itself. The experiments demonstrated that 10 1 -10 5 aluminum ions per pixel can be detected with good linear response. Moreover, relative ion sensitivities from hydrogen to lead were constant within a factor of 2. The performance of this area detector provides the potential for detection of kiloelectronvolt ion images with current ion microscopy

  4. R&D of a high-performance DIRC detector for a future electron-ion collider

    Energy Technology Data Exchange (ETDEWEB)

    Allison, Staceu L. [Old Dominion Univ., Norfolk, VA (United States)

    2017-08-01

    An Electron-Ion Collider (EIC) is proposed as the next big scientific facility to be built in the United States, costing over $1 billion in design and construction. Each detector concept for the electron/ion beam interaction point is integrated into a large solenoidal magnet. The necessity for excellent hadronic particle identification (pion/kaon/proton) in the barrel region of the solenoid has pushed research and development (R&D) towards a new, high-performance Detection of Internally Reflected Cherenkov light (DIRC) detector design. The passage of a high energy charged particle through a fused silica bar of the DIRC generates optical Cherenkov radiation. A large fraction of this light propagates by total internal reflection to the end of the bar, where the photon trajectories expand in a large volume before reaching a highly segmented photo-detector array. The spatial and temporal distribution of the Cherenkov light at the photo-detector array allows one to reconstruct the angle of emission of the light relative to the incident charged particle track. In order to reach the desired performance of 3sigma pi/K separation at 6 GeV/c particle momentum a new 3-layer spherical lens focusing optic with a lanthanum crown glass central layer was designed to have a nearly at focal plane. In order to validate the EIC DIRC simulation package, a synergistic test beam campaign was carried out in 2015 at the CERN PS with the PANDA Barrel DIRC group using a prototype DIRC detector. Along with the analysis of the CERN test beam data, measurements of the focal plane of the 3-layer lens were performed using a custom-built laser setup at Old Dominion University. Radiation hardness of the lanthanum crown glass was tested using a 160 keV X-ray source and a monochromator at the Catholic University of America. Results of these test-bench experiments and the analysis of the 2015 CERN test beam data are presented here.

  5. R&D of a High-Performance DIRC Detector for a Future Electron-Ion Collider

    Science.gov (United States)

    Allison, Stacey Lee

    An Electron-Ion Collider (EIC) is proposed as the next big scientific facility to be built in the United States, costing over $1 billion in design and construction. Each detector concept for the electron/ion beam interaction point is integrated into a large solenoidal magnet. The necessity for excellent hadronic particle identification (pion/kaon/proton) in the barrel region of the solenoid has pushed research and development (R&D) towards a new, high-performance Detection of Internally Reflected Cherenkov light (DIRC) detector design. The passage of a high energy charged particle through a fused silica bar of the DIRC generates optical Cherenkov radiation. A large fraction of this light propagates by total internal reflection to the end of the bar, where the photon trajectories expand in a large volume before reaching a highly segmented photo-detector array. The spatial and temporal distribution of the Cherenkov light at the photo-detector array allows one to reconstruct the angle of emission of the light relative to the incident charged particle track. In order to reach the desired performance of 3sigma pi/K separation at 6 GeV/c particle momentum a new 3-layer spherical lens focusing optic with a lanthanum crown glass central layer was designed to have a nearly flat focal plane. In order to validate the EIC DIRC simulation package, a synergistic test beam campaign was carried out in 2015 at the CERN PS with the PANDA Barrel DIRC group using a prototype DIRC detector. Along with the analysis of the CERN test beam data, measurements of the focal plane of the 3-layer lens were performed using a custom-built laser setup at Old Dominion University. Radiation hardness of the lanthanum crown glass was tested using a 160 keV X-ray source and a monochromator at the Catholic University of America. Results of these test-bench experiments and the analysis of the 2015 CERN test beam data are presented here.

  6. Active Radiation Detectors for Use in Space Beyond Low Earth Orbit: Spatial and Energy Resolution Requirements and Methods for Heavy Ion Charge Classification

    Science.gov (United States)

    McBeth, Rafe A.

    Space radiation exposure to astronauts will need to be carefully monitored on future missions beyond low earth orbit. NASA has proposed an updated radiation risk framework that takes into account a significant amount of radiobiological and heavy ion track structure information. These models require active radiation detection systems to measure the energy and ion charge Z. However, current radiation detection systems cannot meet these demands. The aim of this study was to investigate several topics that will help next generation detection systems meet the NASA objectives. Specifically, this work investigates the required spatial resolution to avoid coincident events in a detector, the effects of energy straggling and conversion of dose from silicon to water, and methods for ion identification (Z) using machine learning. The main results of this dissertation are as follows: 1. Spatial resolution on the order of 0.1 cm is required for active space radiation detectors to have high confidence in identifying individual particles, i.e., to eliminate coincident events. 2. Energy resolution of a detector system will be limited by energy straggling effects and the conversion of dose in silicon to dose in biological tissue (water). 3. Machine learning methods show strong promise for identification of ion charge (Z) with simple detector designs.

  7. Use of a new ion-detector in the study of the jet plasma injected into a pulsed magnetic mirror configuration (deca I)

    International Nuclear Information System (INIS)

    Renaud, C.

    1963-01-01

    The study of a high sensitivity ion detector coupled to an electrostatic analyser has permitted a large investigation of the plasma jet injected into a pulsed magnetic mirror configuration. In this detector the positive ions are accelerated through a potential of 30 kV; they strike a metallic target, on which they produce secondary electrons; these, in turn, are accelerated onto a plastic scintillator. The light pulses are detected with a photomultiplier. The gain of this device is about 10 7 . If we make an admission of air into the vacuum system and again we make vacuum, the gain is not modified, since no special activated surfaces are situated in the detector. (author) [fr

  8. Multiline digital radiographic imager study with synchronization to detector gas ion drift

    International Nuclear Information System (INIS)

    Peyret, O.

    1985-01-01

    This direct digital radiographic imager is based on X-ray detection in high pressure rare gas ionization chamber. This linear multidetector, from which scanning radiography is realized, records many lines together. Spatial resolution performance in scanning direction are made sure by scanning synchronization with ion drift in detector. After a physical study and a potential evaluation of its performances on mock-up, a 128 cell prototype has been realized. The first images give validation and limits of such a radiographic process [fr

  9. Diogene: A 4π detector, based on a time projection chamber, for studying central collisions of relativistic heavy ions

    International Nuclear Information System (INIS)

    Gosset, J.

    1981-01-01

    'Diogene' is the name we have chosen for a 4π solid angle detector, based on a Time Projection Chamber, designed to perform exclusive measurements of charged particles emitted in central collisions or relativistic heavy ions. This detector is being developed by a collaboration between physicists from Saclay, Strasbourg and Clermont Ferrand, to be installed at the Saturne Synchrotron in Saclay. I first give the motivations for our choice of a TPC rather than any other kind of detector, then I recall the principle of such a detector, before describing it with more detail and describing its present status and forsean capabilities, including some discussion about the possible extension of such a detector towards higher energies and/or heavier beams. (orig.)

  10. Diogene: a 4π detector, based on a time projection chamber, for studying central collisions of relativistic heavy ions

    International Nuclear Information System (INIS)

    Gosset, J.

    1980-10-01

    'Diogene' is the name we have chosen for a 4π solid angle detector, based on a Time Projection Chamber (TPC), designed to perform exclusive measurements of charged particles emitted in central collisions or relativistic heavy ions This detector is being developed by a collaboration between physicists from Saclay, Strasbourg and Clermont-Ferrand, to be installed at the Saturne Synchrotron in Saclay. I shall first give the motivations for our choice of a TPC rather than any other kind of detector, than recall the principle of such a detector, before describing it with more detail and describing its present status and forsean capabilities, including some discussion about the possible extension of such a detector towards higher energies and/or heavier beams

  11. GEOS-2 measurements of cold ions in the magnetosheath

    International Nuclear Information System (INIS)

    Rodgers, D.J.; Johnstone, A.D.; Sojka, J.J.

    1985-01-01

    The Suprathermal Plasma Analysers on GEOS-2 are able to make differential energy measurements of plasma particles down to sub-eV energies because the entire sensor package can be biased relative to the spacecraft. When the package is biased negatively with respect to space potential, low energy positive ions are sucked in and are more easily detected against the background. Large fluxes of ions with temperatures of the order of 1 eV or less were consistently detected at space potential when the spacecraft was in the magnetosheath though not when it was in the nearby magnetosphere. This apparent geophysical correlation, suggesting that the ions were part of the magnetosheath ion population, was contradicted by the fact that the ions showed no signs of the large drift velocity associated with the electric field in the magnetosheath. It is concluded, after further investigation, that the observed ions were probably sputtered as neutrals from the spacecraft surface by the impact of solar wind ions and subsequently ionized by sunlight or electron impact. The effect of sputtering by solar wind ions has not been previously observed, although it could have consequences for the long-term stability of spacecraft surfaces. (author)

  12. Calorimetric low - temperature detectors for high resolution X-ray spectroscopy on stored highly stripped heavy ions

    International Nuclear Information System (INIS)

    Bleile, A.; Egelhof, P.; Kraft, S.; Meier, H.J.; Shrivastava, A.; Weber, M.; McCammon, D.; Stahle, C.K.

    2001-09-01

    The accurate determination of the Lamb shift in heavy hydrogen-like ions provides a sensitive test of quantum electrodynamics in very strong Coulomb fields, not accessible otherwise. For the investigation of the Lyman-α transitions in 208 Pb 81+ or 238 U 91+ with sufficient accuracy, a high resolution calorimetric detector for hard X-rays (E ≤ 100 keV) is presently being developed. The detector modules consist of arrays of silicon thermistors and of X-ray absorbers made of high-Z material to optimize the absorption efficiency. The detectors are housed in a specially designed 3 He/ 4 He dilution refrigerator with a side arm which fits to the internal target geometry of the storage ring ESR at GSI Darmstadt. The detector performance presently achieved is already close to fulfill the demands of the Lamb shift experiment. For a prototype detector pixel with a 0.2 mm 2 x 47 μm Pb absorber an energy resolution of ΔE FWHM = 65 eV is obtained for 60 keV X-rays. (orig.)

  13. Calibration of solid state nuclear track detectors at high energy ion beams for cosmic radiation measurements: HAMLET results

    International Nuclear Information System (INIS)

    Szabó, J.; Pálfalvi, J.K.

    2012-01-01

    The MATROSHKA experiments and the related HAMLET project funded by the European Commission aimed to study the dose burden of the crew working on the International Space Station (ISS). During these experiments a human phantom equipped with several thousands of radiation detectors was exposed to cosmic rays inside and outside the ISS. Besides the measurements realized in Earth orbit, the HAMLET project included also a ground-based program of calibration and intercomparison of the different detectors applied by the participating groups using high-energy ion beams. The Space Dosimetry Group of the Centre for Energy Research (formerly Atomic Energy Research Institute) participated in these experiments with passive solid state nuclear track detectors (SSNTDs). The paper presents the results of the calibration experiments performed in the years 2008–2011 at the Heavy Ion Medical Accelerator (HIMAC) of the National Institute of Radiological Sciences (NIRS), Chiba, Japan. The data obtained serve as update and improvement for the previous calibration curves which are necessary for the evaluation of the SSNTDs exposed in unknown space radiation fields.

  14. Calibration of solid state nuclear track detectors at high energy ion beams for cosmic radiation measurements: HAMLET results

    Energy Technology Data Exchange (ETDEWEB)

    Szabo, J., E-mail: julianna.szabo@energia.mta.hu [Hungarian Academy of Sciences, Centre for Energy Research, Konkoly Thege Miklos ut 29-33, 1525 Budapest 114, P.O. Box 49 (Hungary); Palfalvi, J.K. [Hungarian Academy of Sciences, Centre for Energy Research, Konkoly Thege Miklos ut 29-33, 1525 Budapest 114, P.O. Box 49 (Hungary)

    2012-12-01

    The MATROSHKA experiments and the related HAMLET project funded by the European Commission aimed to study the dose burden of the crew working on the International Space Station (ISS). During these experiments a human phantom equipped with several thousands of radiation detectors was exposed to cosmic rays inside and outside the ISS. Besides the measurements realized in Earth orbit, the HAMLET project included also a ground-based program of calibration and intercomparison of the different detectors applied by the participating groups using high-energy ion beams. The Space Dosimetry Group of the Centre for Energy Research (formerly Atomic Energy Research Institute) participated in these experiments with passive solid state nuclear track detectors (SSNTDs). The paper presents the results of the calibration experiments performed in the years 2008-2011 at the Heavy Ion Medical Accelerator (HIMAC) of the National Institute of Radiological Sciences (NIRS), Chiba, Japan. The data obtained serve as update and improvement for the previous calibration curves which are necessary for the evaluation of the SSNTDs exposed in unknown space radiation fields.

  15. Calibration of a Thomson parabola ion spectrometer and Fujifilm imaging plate detectors for protons, deuterons, and alpha particles.

    Science.gov (United States)

    Freeman, C G; Fiksel, G; Stoeckl, C; Sinenian, N; Canfield, M J; Graeper, G B; Lombardo, A T; Stillman, C R; Padalino, S J; Mileham, C; Sangster, T C; Frenje, J A

    2011-07-01

    A Thomson parabola ion spectrometer has been designed for use at the Multiterawatt (MTW) laser facility at the Laboratory for Laser Energetics (LLE) at the University of Rochester. This device uses parallel electric and magnetic fields to deflect particles of a given mass-to-charge ratio onto parabolic curves on the detector plane. Once calibrated, the position of the ions on the detector plane can be used to determine the particle energy. The position dispersion of both the electric and magnetic fields of the Thomson parabola was measured using monoenergetic proton and alpha particle beams from the SUNY Geneseo 1.7 MV tandem Pelletron accelerator. The sensitivity of Fujifilm BAS-TR imaging plates, used as a detector in the Thomson parabola, was also measured as a function of the incident particle energy over the range from 0.6 MeV to 3.4 MeV for protons and deuterons and from 0.9 MeV to 5.4 MeV for alpha particles. The device was used to measure the energy spectrum of laser-produced protons at MTW.

  16. Calibration of a Thomson parabola ion spectrometer and Fujifilm imaging plate detectors for protons, deuterons, and alpha particles

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, C. G.; Canfield, M. J.; Graeper, G. B.; Lombardo, A. T.; Stillman, C. R.; Padalino, S. J. [Physics Department, SUNY Geneseo, Geneseo, New York 14454 (United States); Fiksel, G.; Stoeckl, C.; Mileham, C.; Sangster, T. C. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623 (United States); Sinenian, N.; Frenje, J. A. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States)

    2011-07-15

    A Thomson parabola ion spectrometer has been designed for use at the Multiterawatt (MTW) laser facility at the Laboratory for Laser Energetics (LLE) at University of Rochester. This device uses parallel electric and magnetic fields to deflect particles of a given mass-to-charge ratio onto parabolic curves on the detector plane. Once calibrated, the position of the ions on the detector plane can be used to determine the particle energy. The position dispersion of both the electric and magnetic fields of the Thomson parabola was measured using monoenergetic proton and alpha particle beams from the SUNY Geneseo 1.7 MV tandem Pelletron accelerator. The sensitivity of Fujifilm BAS-TR imaging plates, used as a detector in the Thomson parabola, was also measured as a function of the incident particle energy over the range from 0.6 MeV to 3.4 MeV for protons and deuterons and from 0.9 MeV to 5.4 MeV for alpha particles. The device was used to measure the energy spectrum of laser-produced protons at MTW.

  17. Qualitative and quantitative analysis of cations and anions using ion selective detectors in capillary electrophoresis

    International Nuclear Information System (INIS)

    Nann, A.

    1994-01-01

    The present work reports on the application of ion-selective microelectrodes as potentiometric detectors for the qualitative and quantitative analysis of cations and anions separated by capillary electrophoresis. Due to the high internal resistance of microelectrodes, their potentials are strongly affected by external electrical fields. Therefore, the influence of the electrophoretic field on the electrode response had to be kept at a minimum. With the electrode tip inserted in the capillary aperture (on-column detection), heavy drifts and noise of the signals were observed, mainly because the electrophoretic potential is superimposed on the Nernstian electrode response. As the potential inside the capillary is site-dependent, already minor movements and vibrations not perceptible under the light microscopy cause unacceptable disturbances of the electrode signal. One possibility to solve the problem consists in post- or off-column detection, i.e., with the detector located outside the influence of the electrophoretic field. If quantitative analyses with maximum resolution are to be achieved, only on-column detection is suitable because outside the capillary, the separation efficiency drops drastically. By etching the detector-side capillary end to a conical aperture, the field strength in the last 10 μm fell approximately 1/25 as compared with that in a cylindrical one. Thus, potential drifts and noise were reduced correspondingly so that on-column detection can also be used for potentiometric detection. To obtain quantitative results, the signals of the ion-selective detector were first delogarithmized and then integrated over time. Thus, it was possible to quantify cations and anions with a coefficient of variations ≤5%. (author) figs., tabs., 179 refs

  18. Study of jet quenching in heavy ion collisions at LHC using ATLAS detector

    CERN Document Server

    Štefko, Pavol

    2015-01-01

    Quark-Gluon Plasma (QGP) is one of the most extreme states of matter which exists only in extraordinary conditions of heavy-ion collisions that can be achieved at particle accelerators. Interactions between the partons and the hot, dense QGP are expected to cause the loss of the jet energy, which is phenomenon called jet quenching. In this talk we provide an introduction to the problematics of ultra-relativistic heavy ion collisions and we show how the jet quenching can be used to analyze the properties of QGP. We also present some “work in progress” results of the jet analysis done on the data taken by the ATLAS detector during the 2011 heavy-ion run at the LHC. Jets are studied as a function of collision centrality and dijet energy imbalance. Dijets are observed to be increasingly asymmetric with increasing centrality. The study of charged particles indicates an increase of yields of low- p T tracks in events with strongly quenched jets

  19. Electroweak bosons in heavy-ion collisions measured with the ATLAS detector

    CERN Document Server

    Perepelitsa, Dennis; The ATLAS collaboration

    2017-01-01

    Electroweak bosons do not interact strongly with the dense and hot medium formed in nuclear collisions, and thus are sensitive to the nuclear modification of parton distribution functions (nPDFs). The ATLAS detector, optimised to search for new physics in proton-proton interactions, is well equipped to measure photons, W and Z bosons in the high occupancy environment produced in heavy-ion collisions. Results from the ATLAS experiment on photons, W, and Z boson yields in lead-lead and proton-lead collisions are presented. These results have particular importance in the context of understanding the collision geometry and nuclear initial state.

  20. Multi-angle gas and Si detector particle telescope

    International Nuclear Information System (INIS)

    McDonald, R.J.; Sobotka, L.G.; Wozniak, G.J.

    1984-01-01

    A simple gas ΔE and multiple Si E detector telescope (called a WEDGE detector) has been constructed, which is particularly suitable for angular distribution studies of light ion emission from fragments following heavy ion reactions. This inexpensive detector was designed to have a low detection threshold, large dynamic range and constant ΔE path length. The detector has been used in studies of complex fragment emission (typically 2 < Z < 10) following compound nucleus and deep-inelastic heavy ion reactions

  1. A low background-rate detector for ions in the 5 to 50 keV energy range to be used for radioisotope dating with a small cyclotron

    International Nuclear Information System (INIS)

    Friedman, P.G.

    1986-01-01

    Accelerator mass spectrometry in tandem Van de Graaff accelerators has proven successful for radioisotope dating small samples. We are developing a 20 cm diameter 30 to 40 keV cyclotron dedicated to high-sensitivity radioisotope dating, initially for 14 C. At this energy, range and dE/dx methods of particle identification are impossible. Thus arises the difficult problem of reliably detecting 30 to 40 keV 14 C at 10 -2 counts/sec in the high background environment of the cyclotron, where lower energy ions, electrons, and photons bombard the detector at much higher rates. We have developed and tested an inexpensive, generally useful ion detector that allows dark-count rates below 10 -4 counts/sec and excellent background suppression. With the cyclotron tuned near the 13 CH background peak, to the frequency for 14 C, the detector suppresses the background to 6 x 10 -4 counts/sec. For each 14 C ion the detectors grazing-incidence Al 2 O 3 conversion dynode emits about 20 secondary electrons, which are independently multiplied in separate pores of a microchannel plate. The output signal is proportional to the number of secondary electrons, allowing pulse-height discrimination of background. We have successfully tested the detector with positive 12 C, 23 Na, 39 K, 41 K, 85 Rb, 87 Rb, and 133 Cs at 5 to 40 keV, and with 36 keV negative 12 C and 13 CH. It should detect ions and neutrals of all species, at energies above 5 keV, with good efficiency and excellent background discrimination. Counting efficiency and background discrimination improve with higher ion energy. The detector can be operated at least up to 2 x 10 -7 Torr and be repeatedly exposed to air. The maximum rate is 10/sup 6.4/ ions/sec in pulse counting mode and 10/sup 9.7/ ions/sec in current integrating mode

  2. Validation of Am-241 measurement in ion chamber type smoke detector by using gamma spectrometry system

    International Nuclear Information System (INIS)

    Yii Mei Wo; Khairul Nizam Razali

    2005-01-01

    Smoke detectors are useful devices in modern days that able to save many lives. Even though, the use of ion chamber type smoke detector (usually contain Americium-241) was exempted in Malaysia, but the trading of this device was controlled by regulation, under the Atomic Energy Licensing Act (Act 304). The activity of the Am-241 can be measured by using the Gamma Spectrometry System since it was much easier, compared to Alpha Spectrometry System. To do so, the system was first need to be calibrated using the standard reference source to find the efficiency of the germanium detector. The method used for the measurement was first validated for several relevant parameters, which include specificity, precision (repeatability), bias (accuracy), linearity, working range, detection limit, robustness and ruggedness to ensure it was fit for the purpose. The measured Am-241 activity inside the smoke detector will be reported together with a reasonable expanded uncertainty arise from the measurement. (Author)

  3. Ion microtomography using ion time-of-flight

    International Nuclear Information System (INIS)

    Roberts, M.L.; Heikkinen, D.W.; Proctor, I.D.; Pontau, A.E.; Olona, G.T.; Felter, T.E.; Morse, D.H.; Hess, B.V.

    1992-01-01

    We have developed and are in the process of testing an ion time-of-flight (TOF) detector system for use in our ion microtomography measurements. Using TOF, ion energy is determined by measurement of the ion's flight time over a certain path length. For ion microtomography, the principle advantage of TOF analysis is that ion count rates of several hundred thousand counts per second can be achieved as compared to a limit of about ten thousand ions per second when using a solid-state silicon surface barrier detector and associated electronics. This greater than 10 fold increase in count rate correspondingly shortens sample analysis time or increases the amount of data that can be collected on a given sample. Details of the system and progress to date are described

  4. Detection system with a large angular acceptance and an energy high dynamics, for heavy ion physics at intermediate energies: M.E.ω. detector

    International Nuclear Information System (INIS)

    Monnet, F.

    1985-01-01

    Built for intermediate energy heavy ions nuclear physics, the M.E.ω. detector uses various and complementary detection methods: ionization chamber, parallel plate avalanche counter, plastic scintillators. With these techniques, velocity, energy, mass and charge of nuclei were measured over wide range. From the detailed theoretical study of each method, limitations and perturbation causes are deduced. The solutions used for optimizing the detector, and the main results are exposed. The internal sectorisation of the detector, which permits a modulation in counting rate and electronical adjustments, has been revealed to be very suitable for heavy ions intermediate energy physics. Results of the first experiment realised with M.E.ω. (Ar + Ag at 35 MeV/u) are commented [fr

  5. Evaluation of the relative thermoluminescence efficiency of LiF:Mg,Ti and LiF:Mg,Cu,P TL detectors to low-energy heavy ions

    DEFF Research Database (Denmark)

    Gieszczyk, W.; Bilski, P.; Olko, P.

    2013-01-01

    and xenon ion beams, at energies ranging from 5.0 to 9.3 MeV/n. Supra- and sublinear response was found, for the MTS-N and MCP-N, respectively, similarly as observed for γ-rays. However, the level of nonlinearity of response of studied detectors is strongly reduced by increasing values of the ion ionization...... density (no supralinearity for Xe ions, for MTS-N, within calculated uncertainties). The growth of high-temperature TL peaks, with increasing ionization density, was observed for MCP-N, what was not previously reported. At the whole range of applied energies higher efficiencies were noted for MTS......-N, for all ion species. A decrease of the efficiency with decrease of the ion energy was confirmed, for both types of studied detectors. At a given energy, higher efficiency was observed for lighter ions, because of the lower ionization density. Significantly higher decrease of the efficiency was measured...

  6. New sampling electronics using CCD for DIOGENE: a high multiplicity, 4 π detector for relativistic heavy ions

    International Nuclear Information System (INIS)

    Babinet, R.P.

    1987-01-01

    DIOGENE is a small time projection chamber which has been developed to study central collisions of relativistic heavy ions. The maximum multiplicity (up to 40 charged particles) that can be accepted by this detector is limited by the present electronics. In view of the heavier mass ions that should become readily available at the Saturne national facility (France), a new sampling electronics has been tested. In the first part of this talk they will present a brief description of the actual detector, insisting on the performances that have been effectively obtained with α-particles and Neon beams. The motivation for and characteristics of a renewed electronic set-up should thus appear more clearly. The second part of the talk is devoted to results of the tests that have been performed using charged couple devices. They will finally conclude on the future perspectives that have been opened by these developments

  7. Quiet-time Suprathermal (~0.1-1.5 keV) Electrons in the Solar Wind

    Science.gov (United States)

    Tao, Jiawei; Wang, Linghua; Zong, Qiugang; Li, Gang; Salem, Chadi S.; Wimmer-Schweingruber, Robert F.; He, Jiansen; Tu, Chuanyi; Bale, Stuart D.

    2016-03-01

    We present a statistical survey of the energy spectrum of solar wind suprathermal (˜0.1-1.5 keV) electrons measured by the WIND 3DP instrument at 1 AU during quiet times at the minimum and maximum of solar cycles 23 and 24. After separating (beaming) strahl electrons from (isotropic) halo electrons according to their different behaviors in the angular distribution, we fit the observed energy spectrum of both strahl and halo electrons at ˜0.1-1.5 keV to a Kappa distribution function with an index κ and effective temperature Teff. We also calculate the number density n and average energy Eavg of strahl and halo electrons by integrating the electron measurements between ˜0.1 and 1.5 keV. We find a strong positive correlation between κ and Teff for both strahl and halo electrons, and a strong positive correlation between the strahl n and halo n, likely reflecting the nature of the generation of these suprathermal electrons. In both solar cycles, κ is larger at solar minimum than at solar maximum for both strahl and halo electrons. The halo κ is generally smaller than the strahl κ (except during the solar minimum of cycle 23). The strahl n is larger at solar maximum, but the halo n shows no difference between solar minimum and maximum. Both the strahl n and halo n have no clear association with the solar wind core population, but the density ratio between the strahl and halo roughly anti-correlates (correlates) with the solar wind density (velocity).

  8. Systematics of Charged Particle Production in Heavy-Ion Collisions with the PHOBOS Detector at Rhic

    Science.gov (United States)

    Steinberg, Peter A.; Back, B. B.; Baker, M. D.; Barton, D. S.; Betts, R. R.; Bindel, R.; Budzanowski, A.; Busza, W.; Carroll, A.; Corbo, J.; Decowski, M. P.; Garcia, E.; George, N.; Gulbrandsen, K.; Gushue, S.; Halliwell, C.; Hamblen, J.; Henderson, C.; Hicks, D.; Hofman, D.; Hollis, R. S.; Hołyński, R.; Holzman, B.; Iordanova, A.; Johnson, E.; Kane, J.; Katzy, J.; Khan, N.; Kucewicz, W.; Kulinich, P.; Kuo, C. M.; Lin, W. T.; Manly, S.; McLeod, D.; Michałowski, J.; Mignerey, A.; Mülmenstädt, J.; Nouicer, R.; Olszewski, A.; Pak, R.; Park, I. C.; Pernegger, H.; Rafelski, M.; Rbeiz, M.; Reed, C.; Remsberg, L. P.; Reuter, M.; Roland, C.; Roland, G.; Rosenberg, L.; Sagerer, J.; Sarin, P.; Sawicki, P.; Skulski, W.; Steadman, S. G.; Steinberg, P.; Stephans, G. S. F.; Stodulski, M.; Sukhanov, A.; Tang, J.-L.; Teng, R.; Trzupek, A.; Vale, C.; van Nieuwenhuizen, G. J.; Verdier, R.; Wadsworth, B.; Wolfs, F. L. H.; Wosiek, B.; Woźniak, K.; Wuosmaa, A. H.; Wysłouch, B.

    2002-03-01

    The multiplicity of charged particles produced in Au+Au collisions as a function of energy, centrality, rapidity and azimuthal angle has been measured with the PHOBOS detector at RHIC. These results contribute to our understanding of the initial state of heavy ion collisions and provide a means to compare basic features of particle production in nuclear collisions with more elementary systems.

  9. Measurements of energetic ions produced by high-energy laser pulses by means of solid-state nuclear track detectors

    Czech Academy of Sciences Publication Activity Database

    Szydlowski, A.; Badziak, A.; Parys, P.; Wolowski, J.; Woryna, E.; Jungwirth, Karel; Králiková, Božena; Krása, Josef; Láska, Leoš; Pfeifer, Miroslav; Rohlena, Karel; Skála, Jiří; Ullschmied, Jiří; Boody, F. D.; Gammino, S.; Torrisi, L.

    2004-01-01

    Roč. 7, č. 3 (2004), s. 327-332 ISSN 1093-3611 Institutional research plan: CEZ:AV0Z1010921 Keywords : iodine laser * nuclear track detectors * ions Subject RIV: BH - Optics, Masers, Lasers Impact factor: 0.194, year: 2004

  10. Helium ion distributions in a 4 kJ plasma focus device by 1 mm-thick large-size polycarbonate detectors

    Science.gov (United States)

    Sohrabi, M.; Habibi, M.; Ramezani, V.

    2014-11-01

    Helium ion beam profile, angular and iso-ion beam distributions in 4 kJ Amirkabir plasma focus (APF) device were effectively observed by the unaided eyes and studied in single 1 mm-thick large-diameter (20 cm) polycarbonate track detectors (PCTD). The PCTDs were processed by 50 Hz-HV electrochemical etching using a large-size ECE chamber. The results show that helium ions produced in the APF device have a ring-shaped angular distribution peaked at an angle of ∼ ± 60 ° with respect to the top of the anode. Some information on the helium ion energy and distributions is also provided. The method is highly effective for ion beam studies.

  11. Study of heavy ions collision at SIS energies with the detector FOPI; Etude des collisions d'ions lourds aux energies de SIS avec le detecteur FOPI

    Energy Technology Data Exchange (ETDEWEB)

    Bastid, N

    1999-09-23

    The present work has been carried out in the framework of experiments performed with the FOPI detector at the SIS/ESR accelerator facility of GSI-Darmstadt. It is devoted to the study of central and semi-central heavy ion collisions at beam energies ranging from 100 MeV to 2 GeV per nucleon. We present first generalities on relativistic heavy ion collisions then the FOPI detector with a special attention to the FOPI Inner Wall constructed by the Clermont-Ferrand group. The main results of the FOPI collaboration obtained with light and intermediate mass fragments and kaons are presented. A systematic study of the different forms of collection motion of nuclear matter, radial flow in very central reactions, sideward flow and squeeze-out in semi-central collisions, is performed. Further exciting possibilities concerning production and propagation of strangeness at SIS energies will be offered soon with the upgrade of the FOPI detector. The FOPI data have introduced constraints on parameters of theoretical models. Important progress concerning the knowledge of the properties of nuclear matter, the dynamics of the collisions and in-medium effects have been achieved. (author)

  12. Design innovations in neutron and gamma detectors

    International Nuclear Information System (INIS)

    Prasad, K.R.

    2003-01-01

    Neutron and gamma radiation needs to be monitored in most nuclear installations since it is highly penetrating. On-line monitoring of these radiations is very important for the safe and controlled operation of nuclear reactors, accelerators etc. Several design innovations have been carried out on gas ionisation detectors such as boron-lined proportional counters and ion chambers, fission detectors, gamma ion chambers as well as self-powered detectors. The use of additional structures within boron-lined detectors has enhanced their neutron sensitivity without a corresponding increase in the unwanted gamma sensitivity. The neutron sensitivity of fission counters can be enhanced by designing them as transmission line devices. Ion chambers with two and six pairs of electrodes have been developed for monitoring pulsed x-ray background at accelerator areas. Ion chambers have been employed at gamma fields up to 80 kR/h by deriving the exposure levels on-line using microcontroller devices programmed on the basis of theoretical and empirical formulas. The use of gas electron multiplier foils is proposed for charge multiplication in ion chambers. Self-powered detectors with new emitter materials like Hi, Ni and Inconel have been developed. (author)

  13. Heavy-ion test of detectors with conventional and resistive Micromegas used in TPC configuration

    Energy Technology Data Exchange (ETDEWEB)

    Ducret, Jean-Eric, E-mail: jean-eric.ducret@cea.f [Commissariat a l' Energie Atomique, IRFU, F91191 Gif sur Yvette (France); Legou, Philippe [Commissariat a l' Energie Atomique, IRFU, F91191 Gif sur Yvette (France); Lukasik, Jerzy [Institute of Nuclear Physics, IFJ-PAN, ul. Radzikowskiego 152, 31-342 Krakow (Poland); Boudard, Alain; Combet, Michel [Commissariat a l' Energie Atomique, IRFU, F91191 Gif sur Yvette (France); Czech, BronisLaw [Institute of Nuclear Physics, IFJ-PAN, ul. Radzikowskiego 152, 31-342 Krakow (Poland); Durand, Robert; Gorbinet, Thomas; Le Bourlout, Pascal; Leray, Sylvie [Commissariat a l' Energie Atomique, IRFU, F91191 Gif sur Yvette (France); Matousek, Vladislav [Institute of Physics, Slovak Academy of Sciences, Dubravska cesta 9, 854 11 Bratislava (Slovakia); Nizery, Francois [Commissariat a l' Energie Atomique, IRFU, F91191 Gif sur Yvette (France); PawLowski, Piotr [Institute of Nuclear Physics, IFJ-PAN, ul. Radzikowskiego 152, 31-342 Krakow (Poland); Salsac, Marie-Delphine [Commissariat a l' Energie Atomique, IRFU, F91191 Gif sur Yvette (France); Yordanov, Orlin [Institute of Nuclear Research and Nuclear Energy, Bulgarian Academy of Sciences, 72, Tzanigradsko chaussee Blvd, BG-1784 Sofia (Bulgaria)

    2011-02-01

    We have performed tests of Micromegas detector prototypes using the heavy-ion beams from the SIS synchrotron of GSI (Darmstadt, Germany). The beams varied from {sup 12}C{sup 6+} to {sup 179}Au{sup 65+} and from 250 to 1000 MeV per nucleon. We have tested two amplification technologies, conventional and resistive Micromegas, and two construction concepts, bulk-Micromegas and micro-meshes screwed on the PCB. The obtained position resolution below 200{mu}m for 5 mm wide strips implies that the bulk resistive Micromegas technology might meet the requirements of the future R3B TPC project. We also developed a fast and very low noise front-end electronics connected directly to the Printed Circuit Board (PCB) of the detector itself. This concept has shown very good performances and robustness.

  14. Comparison of silicon pin diode detector fabrication processes using ion implantation and thermal doping

    International Nuclear Information System (INIS)

    Zhou, C.Z.; Warburton, W.K.

    1996-01-01

    Two processes for the fabrication of silicon p-i-n diode radiation detectors are described and compared. Both processes are compatible with conventional integrated-circuit fabrication techniques and yield very low leakage currents. Devices made from the process using boron thermal doping have about a factor of 2 lower leakage current than those using boron ion implantation. However, the boron thermal doping process requires additional process steps to remove boron skins. (orig.)

  15. Sensitive beam-bunch phase detector

    Energy Technology Data Exchange (ETDEWEB)

    Takeuchi, S; Shepard, K W

    1984-11-15

    A sensitive heavy-ion beam-bunch phase detector has been developed by first examining the relationship between the sensitivity of an rf resonant cavity as a particle bunch detector and the shunt impedance of the same cavity as an accelerating structure. Then the various high shunt impedance rf cavities previously developed for accelerating heavy ions were evaluated for use as bunch detectors. A spiral-loaded geometry was chosen, built, and tested with beam. The sensitivity obtained, 14 V per electrical nA of beam, is a factor 3 higher than previously reported. (orig.).

  16. Sensitive beam-bunch phase detector

    Energy Technology Data Exchange (ETDEWEB)

    Takeuchi, S; Shepard, K W [Argonne National Lab., IL (USA). Physics Div.

    1984-11-15

    A sensitive heavy-ion beam-bunch phase detector has been developed by first examining the relationship between the sensitivity of an RF resonant cavity as a particle bunch detector and the shunt impedance of the same cavity as an accelerating structure. Then the various high shunt impedance RF cavities previously developed for accelerating heavy ions were evaluated for use as bunch detectors. A spiral-loaded geometry was chosen, built, and tested with beam. The sensitivity obtained, 14 ..mu.. V per electrical nA of beam, is a factor 3 higher than previously reported.

  17. A new detector array for charged particle spectroscopy

    CERN Document Server

    Cowin, R L; Chappell, S P G; Clarke, N M; Freer, M; Fulton, B R; Cunningham, R A; Curtis, N; Dillon, G; Lilley, J; Jones, C D; Lee, P; Rae, W D M

    1999-01-01

    A compact and highly segmented detector array consisting of 44 gas-silicon-caesium iodide, position sensitive, particle identification detector telescopes and up to 10 position-sensitive, silicon strip detectors has been constructed for the study of light-ion-heavy-ion reactions including cluster break-up in the energy range 5-15 MeV/nucleon. The detectors are housed in a purpose built vacuum chamber. The telescopes are placed in fixed positions, covering the forward hemisphere from 3 to 30 deg. in the laboratory with the target placed at 535 mm from the front of the telescopes or 6-52 deg. with the target placed at 215 mm. The strip detectors are placed in any of 30 fixed positions in the forward hemisphere. For 85 MeV sup 1 sup 2 C ions the telescope energy resolution (gas plus silicon) is 345 keV with an angular resolution of 0.03 deg. . Using the gas-silicon section ions with Z up to 21 can be identified. For ions that pass through the silicon isotopic identification is achieved using the silicon-CsI comb...

  18. Development of Detector Systems for Internal and Fixed Target Heavy Ion Physics Experiments

    International Nuclear Information System (INIS)

    Golubev, Pavel

    2003-04-01

    This thesis deals with intermediate energy heavy ion reactions with the particular aim to study the nuclear matter equation of state which defines the relation between statistical parameters of a fermionic system. The development of equipment for two experiments, CA47 at The Svedberg Laboratory in Uppsala, Sweden and R16 at Kernfysisch Versneller Inst. (KVI), Groningen, The Netherlands, are described. CA47 contains the CHICSi detector, a modular, ultra-high vacuum (UHV) compatible, multi-detector system, covering a solid angle of 3pi sr around the collision point. Together with two auxiliary detector systems CHICSi is placed at the cluster-jet target chamber of the CELSIUS storage ring. This thesis gives a technical overview of the detector and the development carried out in order to achieve the desired detection performance. Some laboratory and in-beam tests are described and the analysis of the first experimental results is discussed. The nuclear intensity interferometry experiment (R16) was performed in a dedicated beam-line of the AGOR superconducting cyclotron. Small-angle two-particle correlations were measured for the E/A = 61 MeV 36 Ar + 27 Al, 112 Sn, 124 Sn reactions, together with singles spectra. The experimental energy distributions of neutrons and light charged particles for the 36 Ar + 27 Al reaction have been analyzed with a Maxwellian multi-source prescription. These results, together with correlation function data, are used to extract information on the size of the emitting sources and their time evolution

  19. IODA - a fast, automated and flexible system for ion track analysis on film detectors

    International Nuclear Information System (INIS)

    Guth, H.; Hellmann, A.

    1995-02-01

    The IODA System (Ion Density Analysis) is used to analyse detector films, resulting from experiments at the pulse power generator KALIF (Karlsruhe Light Ion Facility). The system consists of evaluation software and a microcomputer, which controls a microscope, a video interface, and a multiprocessor subsystem. The segmentation of ion tracks is done automatically by means of digital image processing and pattern recognition. After defining an evaluation range and selecting a suitable analysis method, the film is scanned by the microscope for counting the impacts of the underlying image. According to the appearance of the ion tracks on the film, different methods can be selected. The evaluation results representing the ion density are stored in a matrix. The time needed for an evaluation at a high resolution can be shortened by shipping time consuming pattern recognition calculations to the multiprocessor subsystem. The bottlenecks of the system are the data transfer and the speed of the microscope stage. Simple handling of the system even on alphanumeric terminals had been an important design issue. This was implemented by a logically structured menue system including online help features. This report can be used a s a manual to support the user with system operation. (orig.) [de

  20. Mapping and uncertainty analysis of energy and pitch angle phase space in the DIII-D fast ion loss detector

    Energy Technology Data Exchange (ETDEWEB)

    Pace, D. C., E-mail: pacedc@fusion.gat.com; Fisher, R. K.; Van Zeeland, M. A. [General Atomics, PO Box 85608, San Diego, California 92186-5608 (United States); Pipes, R. [Department of Physics, University of Hawaii, Hilo, Hawaii 96720-4091 (United States)

    2014-11-15

    New phase space mapping and uncertainty analysis of energetic ion loss data in the DIII-D tokamak provides experimental results that serve as valuable constraints in first-principles simulations of energetic ion transport. Beam ion losses are measured by the fast ion loss detector (FILD) diagnostic system consisting of two magnetic spectrometers placed independently along the outer wall. Monte Carlo simulations of mono-energetic and single-pitch ions reaching the FILDs are used to determine the expected uncertainty in the measurements. Modeling shows that the variation in gyrophase of 80 keV beam ions at the FILD aperture can produce an apparent measured energy signature spanning across 50-140 keV. These calculations compare favorably with experiments in which neutral beam prompt loss provides a well known energy and pitch distribution.

  1. Mapping and uncertainty analysis of energy and pitch angle phase space in the DIII-D fast ion loss detector.

    Science.gov (United States)

    Pace, D C; Pipes, R; Fisher, R K; Van Zeeland, M A

    2014-11-01

    New phase space mapping and uncertainty analysis of energetic ion loss data in the DIII-D tokamak provides experimental results that serve as valuable constraints in first-principles simulations of energetic ion transport. Beam ion losses are measured by the fast ion loss detector (FILD) diagnostic system consisting of two magnetic spectrometers placed independently along the outer wall. Monte Carlo simulations of mono-energetic and single-pitch ions reaching the FILDs are used to determine the expected uncertainty in the measurements. Modeling shows that the variation in gyrophase of 80 keV beam ions at the FILD aperture can produce an apparent measured energy signature spanning across 50-140 keV. These calculations compare favorably with experiments in which neutral beam prompt loss provides a well known energy and pitch distribution.

  2. Trajectory bending and energy spreading of charged ions in time-of-flight telescopes used for ion beam analysis

    International Nuclear Information System (INIS)

    Laitinen, Mikko; Sajavaara, Timo

    2014-01-01

    Carbon foil time pick-up detectors are widely used in pairs in ion beam applications as time-of-flight detectors. These detectors are suitable for a wide energy range and for all ions but at the lowest energies the tandem effect limits the achievable time of flight and therefore the energy resolution. Tandem effect occurs when an ion passes the first carbon foil of the timing detector and its charge state is changed. As the carbon foil of the first timing detector has often a non-zero voltage the ion can accelerate or decelerate before and after the timing detector. The combination of different charge state properties before and after the carbon foil now induces spread to the measured times of flight. We have simulated different time pick-up detector orientations, voltages, ions and ion energies to examine the tandem effect in detail and found out that the individual timing detector orientation and the average ion charge state have a very small influence to the magnitude of the tandem effect. On the other hand, the width of the charge state distribution for particular ion and energy in the first carbon foil, and the carbon foil voltage contributes linearly to the magnitude of the tandem effect. In the simulations low energy light ion trajectories were observed to bend in the electric fields of the first timing gate, and the magnitude of this bending was studied. It was found out that 50–150 keV proton trajectories can even bend outside the second timing gate

  3. Performance of the Recoil Mass Spectrometer and its detector systems at the Holifield Radioactive Ion Beam Facility

    International Nuclear Information System (INIS)

    Gross, C.J.; Ginter, T.N.; Shapira, D.; Milner, W.T.; McConnell, J.W.; James, A.N.; Johnson, J.W.; Mas, J.; Mantica, P.F.; Auble, R.L.; Das, J.J.; Blankenship, J.L.; Hamilton, J.H.; Robinson, R.L.; Akovali, Y.A.; Baktash, C.; Batchelder, J.C.; Bingham, C.R.; Brinkman, M.J.; Carter, H.K.; Cunningham, R.A.; Davinson, T.; Fox, J.D.; Galindo-Uribarri, A.; Grzywacz, R.; Liang, J.F.; MacDonald, B.D.; MacKenzie, J.; Paul, S.D.; Piechaczek, A.; Radford, D.C.; Ramayya, A.V.; Reviol, W.; Rudolph, D.; Rykaczewski, K.; Toth, K.S.; Weintraub, W.; Williams, C.; Woods, P.J.; Yu, C.-H.; Zganjar, E.F.

    2000-01-01

    The recently commissioned Recoil Mass Spectrometer (RMS) at the Holifield Radioactive Ion Beam Facility (HRIBF) is described. Consisting of a momentum separator followed by an E-D-E Rochester-type mass spectrometer, the RMS is the centerpiece of the nuclear structure endstation at the HRIBF. Designed to transport ions with rigidities near K=100, the RMS has acceptances of ±10% in energy and ±4.9% in mass-to-charge ratio. Recent experimental results are used to illustrate the detection capabilities of the RMS, which is compatible with many detectors and devices

  4. Department of Radiation Detectors: Overview

    International Nuclear Information System (INIS)

    Piekoszewski, J.

    1999-01-01

    Full text: Work carried out in 1998 in the Department of Radiation Detectors concentrated on three subjects: (i) Semiconductor Detectors (ii) X-ray Tube Generators (iii) Material Modification Using Ion and Plasma Beams. SEMICONDUCTOR DETECTORS: Semiconductor detectors of ionizing radiation are among the basic tools utilized in such fields of research and industry as nuclear physics, high energy physics, medical (oncology) radiotherapy, radiological protection, environmental monitoring, energy dispersive X-ray fluorescence non-destructive analysis of chemical composition, nuclear power industry. The departmental objectives are: a search for new types of detectors; producing unique detectors tailored for physics experiments; manufacturing standard detectors for radiation measuring instruments; scientific development of the staff. These objectives were accomplished in 1998 particularly by: research on unique thin silicon detectors for identification of particles in E-ΔE telescopes, modernization of technology of manufacturing Ge(Li) detectors capable of detecting broader range of gamma energies, manufacturing detectors developed in previous years, re-generating and servicing customer detectors of various origin. In accomplishment of the above the Department co-operated with groups of physicists from IPJ, PAN Institute of Physics (Warsaw), and with some technology Institutes based in Warsaw (ITME, ITE). Some detectors and services have been delivered to customers on a commercial basis. X-Ray TUBE GENERATORS: The Department conducts research on design and technology of manufacturing X-ray generators as well as on imaging and dosimetry of X-ray beams. Various models of special construction X-ray tubes and their power supplies are under construction. In 1998 work concentrated on: completing laboratory equipment for manufacturing X-ray tubes and their components, developing technology of manufacturing X-ray tubes and their components, completing a laboratory set-up with

  5. GANIL beam profile detectors

    International Nuclear Information System (INIS)

    Tribouillard, C.

    1997-01-01

    In the design phase of GANIL which started in 1977, one of the priorities of the project management was equipping the beamlines with a fast and efficient system for visualizing the beam position, thus making possible adjustment of the beam transport lines optics and facilitating beam control. The implantation of some thirty detectors was foreseen in the initial design. The assembly of installed detectors (around 190) proves the advantages of these detectors for displaying all the beams extracted from GANIL: transfer and transport lines, beam extracted from SISSI, very high intensity beam, secondary ion beams from the production target of the LISE and SPEG spectrometers, different SPIRAL project lines. All of these detectors are based on standard characteristics: - standard flange diameter (DN 160) with a standard booster for all the sensors; - identical analog electronics for all the detectors, with networking; - unique display system. The new micro-channel plate non-interceptive detectors (beam profile and ion packet lengths) make possible in-line control of the beam quality and accelerator stability. (author)

  6. Testing of multigap Resistive Plate Chambers for Electron Ion Collider Detector Development

    Science.gov (United States)

    Hamilton, Hannah; Phenix Collaboration

    2015-10-01

    Despite decades of research on the subject, some details of the spin structure of the nucleon continues to be unknown. To improve our knowledge of the nucleon spin structure, the construction of a new collider is needed. This is one of the primary goals of the proposed Electron Ion Collider (EIC). Planned EIC spectrometers will require good particle identification. This can be provided by time of flight (TOF) detectors with excellent timing resolutions of 10 ps. A potential TOF detector that could meet this requirement is a glass multigap resistive plate chamber (mRPC). These mRPCs can provide excellent timing resolution at a low cost. The current glass mRPC prototypes have a total of twenty 0.1 mm thick gas gaps. In order to test the feasibility of this design, a cosmic test stand was assembled. This stand used the coincidence of scintillators as a trigger, and contains fast electronics. The construction, the method of testing, and the test results of the mRPCs will be presented.

  7. Hiss or equatorial noise? Ambiguities in analyzing suprathermal ion plasma wave resonance

    Czech Academy of Sciences Publication Activity Database

    Sarno-Smith, L. K.; Liemohn, M. W.; Skoug, R. M.; Santolík, Ondřej; Morley, S. K.; Breneman, A.; Larsen, B. A.; Reeves, G.; Wygant, J. R.; Hospodarsky, G.; Kletzing, C.; Moldwin, M. B.; Katus, R. M.; Zou, S.

    2016-01-01

    Roč. 121, č. 10 (2016), s. 9619-9631 ISSN 2169-9380 R&D Projects: GA MŠk(CZ) LH15304 Grant - others:AV ČR(CZ) AP1401 Program:Akademická prémie - Praemium Academiae Institutional support: RVO:68378289 Keywords : equatorial noise * low-energy ions * plasma waves * plasmasphere * plasmaspheric hiss Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.733, year: 2016 http://onlinelibrary.wiley.com/doi/10.1002/2016JA022975/abstract

  8. CHICSi - a 3π multi-detector system for studying heavy ion interactions inside a storage ring

    International Nuclear Information System (INIS)

    Avdeichikov, V.; Carlen, L.; Fokin, A.; Jakobsson, J.; Murin, Yu.; Maartensson, J.; Oskarsson, A.; van Veldhuizen, E.J.; Westerberg, L.; Whitlow, H.J.

    1996-01-01

    CHICSi - a 3π multi-detector system is presented. The setup consists of 576 ultra high vacuum compatible telescopes to study intermediate energy heavy ion as well as proton induced collisions at storage rings operating in slow ramping mode. Primary it will be installed at the gas-jet target station of the CELSIUS facility at The Svedberg Laboratory in Uppsala. (orig.)

  9. Interaction mean free path measurements for relativistic heavy ion fragments using CR39 plastic track detectors

    International Nuclear Information System (INIS)

    Drechsel, H.; Brechtmann, C.; Dreute, J.; Sonntag, S.; Trakowski, W.; Beer, J.; Heinrich, W.

    1984-01-01

    This paper describes an experiment measuring the interaction mean free paths for charge changing nuclear collisions of relativistic heavy ion fragments. We use a stack of CR39 plastic nuclear track detectors that was irradiated with 1.8 GeV/nucleon 40 Ar ions at the Berkeley Bevalac. About 1.5 x 10 7 etch cones were measured in this experiment using an automatic measuring system. By tracing the etch cones over successive plastic foils the particle trajectories in the stack were reconstructed. For 14185 trajectories with 6444 nuclear collisions of fragments with charge 9-15 the interaction mean free path in the plastic was determined. (orig.)

  10. Opacity broadening and interpretation of suprathermal CO linewidths: Macroscopic turbulence and tangled molecular clouds

    Science.gov (United States)

    Hacar, A.; Alves, J.; Burkert, A.; Goldsmith, P.

    2016-06-01

    Context. Since their first detection in the interestellar medium, (sub-)millimeter line observations of different CO isotopic variants have routinely been employed to characterize the kinematic properties of the gas in molecular clouds. Many of these lines exhibit broad linewidths that greatly exceed the thermal broadening expected for the low temperatures found within these objects. These observed suprathermal CO linewidths are assumed to originate from unresolved supersonic motions inside clouds. Aims: The lowest rotational J transitions of some of the most abundant CO isotopologues, 12CO and 13CO, are found to present large optical depths. In addition to well-known line saturation effects, these large opacities present a non-negligible contribution to their observed linewidths. Typically overlooked in the literature, in this paper we aim to quantify the impact of these opacity broadening effects on the current interpretation of the CO suprathermal line profiles. Methods: Combining large-scale observations and LTE modeling of the ground J = 1-0 transitions of the main 12CO, 13CO, C18O isotopologues, we have investigated the correlation of the observed linewidths as a function of the line opacity in different regions of the Taurus molecular cloud. Results: Without any additional contributions to the gas velocity field, a large fraction of the apparently supersonic (ℳ ~ 2-3) linewidths measured in both 12CO and 13CO (J = 1-0) lines can be explained by the saturation of their corresponding sonic-like, optically thin C18O counterparts assuming standard isotopic fractionation. Combined with the presence of multiple components detected in some of our C18O spectra, these opacity effects also seem to be responsible for most of the highly supersonic linewidths (ℳ > 8-10) detected in some of the broadest 12CO and 13CO spectra in Taurus. Conclusions: Our results demonstrate that most of the suprathermal 12CO and 13CO linewidths reported in nearby clouds like Taurus

  11. Development of Detector Systems for Internal and Fixed Target Heavy Ion Physics Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Golubev, Pavel

    2003-04-01

    This thesis deals with intermediate energy heavy ion reactions with the particular aim to study the nuclear matter equation of state which defines the relation between statistical parameters of a fermionic system. The development of equipment for two experiments, CA47 at The Svedberg Laboratory in Uppsala, Sweden and R16 at Kernfysisch Versneller Inst. (KVI), Groningen, The Netherlands, are described. CA47 contains the CHICSi detector, a modular, ultra-high vacuum (UHV) compatible, multi-detector system, covering a solid angle of 3pi sr around the collision point. Together with two auxiliary detector systems CHICSi is placed at the cluster-jet target chamber of the CELSIUS storage ring. This thesis gives a technical overview of the detector and the development carried out in order to achieve the desired detection performance. Some laboratory and in-beam tests are described and the analysis of the first experimental results is discussed. The nuclear intensity interferometry experiment (R16) was performed in a dedicated beam-line of the AGOR superconducting cyclotron. Small-angle two-particle correlations were measured for the E/A = 61 MeV {sup 36}Ar + {sup 27}Al, {sup 112}Sn, {sup 124}Sn reactions, together with singles spectra. The experimental energy distributions of neutrons and light charged particles for the {sup 36}Ar + {sup 27}Al reaction have been analyzed with a Maxwellian multi-source prescription. These results, together with correlation function data, are used to extract information on the size of the emitting sources and their time evolution.

  12. Dielectric polarization and electric field distortion due to heavy ions impinging on silicon detectors

    International Nuclear Information System (INIS)

    Parlog, M.; Wieleczko, J.P.; Parlog, M.; Hamrita, H.; Borderie, B.; Lavergne, L.; Rivet, M.F.

    2003-01-01

    The polarization of the electron-hole pairs induced by 80 MeV 12 C in a silicon detector was considered and connected to the relative dielectric permittivity, locally increased. The exact coordinate dependence of the modified electric field - inside and outside the ion range - was found as the solution of the one dimension Poisson's equation for the electric potential in this inhomogeneous medium. The improvement of the signal simulation is encouraging, as compared to an undisturbed electric field case. (authors)

  13. Detector to detector corrections: a comprehensive experimental study of detector specific correction factors for beam output measurements for small radiotherapy beams

    DEFF Research Database (Denmark)

    Azangwe, Godfrey; Grochowska, Paulina; Georg, Dietmar

    2014-01-01

    -doped aluminium oxide (Al2O3:C), organic plastic scintillators, diamond detectors, liquid filled ion chamber, and a range of small volume air filled ionization chambers (volumes ranging from 0.002 cm3 to 0.3 cm3). All detector measurements were corrected for volume averaging effect and compared with dose ratios...... measurements, the authors recommend the use of detectors that require relatively little correction, such as unshielded diodes, diamond detectors or microchambers, and solid state detectors such as alanine, TLD, Al2O3:C, or scintillators....

  14. Shielded regenerative neutron detector

    International Nuclear Information System (INIS)

    Terhune, J.H.; Neissel, J.P.

    1978-01-01

    An ion chamber type neutron detector is disclosed which has a greatly extended lifespan. The detector includes a fission chamber containing a mixture of active and breeding material and a neutron shielding material. The breeding and shielding materials are selected to have similar or substantially matching neutron capture cross-sections so that their individual effects on increased detector life are mutually enhanced

  15. Lunar Surface Electric Potential Changes Associated with Traversals through the Earth's Foreshock

    Science.gov (United States)

    Collier, Michael R.; Hills, H. Kent; Stubbs, Timothy J.; Halekas, Jasper S.; Delory, Gregory T.; Espley, Jared; Farrell, William M.; Freeman, John W.; Vondrak, Richard

    2011-01-01

    We report an analysis of one year of Suprathermal Ion Detector Experiment (SIDE) Total Ion Detector (TID) resonance events observed between January 1972 and January 1973. The study includes only those events during which upstream solar wind conditions were readily available. The analysis shows that these events are associated with lunar traversals through the dawn flank of the terrestrial magnetospheric bow shock. We propose that the events result from an increase in lunar surface electric potential effected by secondary electron emission due to primary electrons in the Earth's foreshock region (although primary ions may play a role as well). This work establishes (1) the lunar surface potential changes as the Moon moves through the terrestrial bow shock, (2) the lunar surface achieves potentials in the upstream foreshock region that differ from those in the downstream magnetosheath region, (3) these differences can be explained by the presence of energetic electron beams in the upstream foreshock region and (4) if this explanation is correct, the location of the Moon with respect to the terrestrial bow shock influences lunar surface potential.

  16. An annular ionization detector for quasi-elastic and transfer reaction studies

    CERN Document Server

    Dinesh, B V; Nayak, B K; Biswas, D C; Saxena, A; Pant, L M; Sahu, P K; Choudhury, R K

    2000-01-01

    An annular ionization chamber detector has been developed to study quasi-elastic and transfer reactions in heavy-ion collisions at near-barrier and sub-barrier energies. The important feature of the detector is that it has a near 2 pi coverage in the azimuthal angle phi for the particles entering in the detector at a given theta direction. This feature makes the detector very useful for measurement of the differential cross-sections at backward angles with respect to the beam direction, involving low cross-section reaction channels. The split anode configuration of the detector makes it capable of both particle identification and energy measurement for heavy ions and fission fragments. The detector has been tested using heavy-ion beams from the 14 MV-pelletron accelerator at Mumbai. Results on quasi-elastic excitation function measurements and barrier distribution studies in many heavy-ion reactions using this detector setup are discussed.

  17. A double sided silicon strip detector as a DRAGON end detector

    CERN Document Server

    Wrede, C; Rogers, J G; D'Auria, J M

    2003-01-01

    The new DRAGON facility (detector of recoils and gammas of nuclear reactions), located at the TRlUMF-ISAC Radioactive Beams facility in Vancouver, Canada is now operational. This facility is used to study radiative proton capture reactions in inverse kinematics (heavy ion beam onto a light gaseous target) with both stable beams and radioactive beams of mass A=13-26 in the energy range 0.15-1.5 MeV/u. A double sided silicon strip detector (DSSSD) has been used to detect recoil ions. Tests have been performed to determine the performance of this DSSSD.

  18. Assessment of new small-field detectors against standard-field detectors for practical stereotactic beam data acquisition

    International Nuclear Information System (INIS)

    McKerracher, C.; Thwaites, D.I.

    1999-01-01

    Two new detectors (0.015 cm 3 ion chamber from PTW, 0.6 mm diameter diode from Scanditronix AB) designed specifically for use in small stereotactic fields were compared against similar, more routine, detectors (0.125 cm 3 ion chamber, parallel plate chamber, shielded and unshielded diodes and film). Percentage depth doses, tissue maximum ratios, off-axis ratios and relative output factors were compared for circular fields in the 40-12.5 mm diameter range, with a view to identifying the optimum detector for stereotactic beam data acquisition. Practical suggestions for beam data collection and analysis are made, with an emphasis on what is achievable practically in radiotherapy departments where the primary demand is to provide a routine service. No single detector was found to be ideal, and neither of the two new measurement devices had any significant advantages over more routine devices, in the situations measured. Although the new 0.015 cm 3 ion chamber was an improvement on a 0.125 cm 3 ion chamber in the measurement of profiles, it was still too large when compared with a diode. The new small diode had a low signal to noise ratio which made reliable data difficult to extract and its only advantage is possibly improved resolution in fields smaller than the range tested. The use of a larger unshielded diode is recommended for all measurements, with the additional cross-checking of data against at least one small ion chamber and film. A simple method of obtaining reliable output data from the detectors used is explained. (author)

  19. Multiplicity-Vertex Detector Electronics Development for Heavy-Ion Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Britton, C.L., Jr.; Bryan, W.L.; Emery, M.S. [and others

    1995-12-31

    This paper presents the electronics work performed to date for the Multiplicity-Vertex Detector (MVD) for the PHENIX collaboration at RHIC. The detector consists of approximately 34,000 channels of both silicon strips and silicon pads. The per-channel signal processing chain consists of a pre-amplifier gain stage, a current mode summed multiplicity discriminator, a 64 deep analog memory (simultaneous read/write), an analog correlator, and a 10-bit microsecs ADC. The system controller or Heap Manager, supplies all timing control, data buffering, and data formatting for a single 256-channel multi-chip module (MCM). Each chip set is partitioned into 32-channel sets. Prototype performance for the various blocks will be presented as well as the ionizing radiation damage performance of the 1.2 mu nwell CMOS process used for fabrication.

  20. HIBP primary beam detector

    International Nuclear Information System (INIS)

    Schmidt, T.W.

    1979-01-01

    A position measuring detector was fabricated for the Heavy Ion Beam Probe. The 11 cm by 50 cm detector was a combination of 15 detector wires in one direction and 63 copper bars - .635 cm by 10 cm to measure along an orthogonal axis by means of a current divider circuit. High transmission tungsten meshes provide entrance windows and suppress secondary electrons. The detector dimensions were chosen to resolve the beam position to within one beam diameter

  1. Single crystal silicon carbide detector of emitted ions and soft x rays from power laser-generated plasmas

    Czech Academy of Sciences Publication Activity Database

    Torrisi, L.; Foti, G.; Giuffrida, L.; Puglisi, D.; Wolowski, J.; Badziak, J.; Parys, P.; Rosinski, M.; Margarone, D.; Krása, Josef; Velyhan, Andriy; Ullschmied, Jiří

    2009-01-01

    Roč. 105, č. 12 (2009), 123304/1-123304/7 ISSN 0021-8979 R&D Projects: GA AV ČR IAA100100715 Institutional research plan: CEZ:AV0Z10100523; CEZ:AV0Z20430508 Keywords : laser-produced plasma * SiC detector * ion collector Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 2.072, year: 2009

  2. Rapid pulse annealing of CdZnTe detectors for reducing electronic noise

    Science.gov (United States)

    Voss, Lars; Conway, Adam; Nelson, Art; Nikolic, Rebecca J.; Payne, Stephen A.; Swanberg, Jr., Erik Lars

    2018-05-01

    A combination of doping, rapid pulsed optical and/or thermal annealing, and unique detector structure reduces or eliminates sources of electronic noise in a CdZnTe (CZT) detector. According to several embodiments, methods of forming a detector exhibiting minimal electronic noise include: pulse-annealing at least one surface of a detector comprising CZT for one or more pulses, each pulse having a duration of .about.0.1 seconds or less. The at least one surface may optionally be ion-implanted. In another embodiment, a CZT detector includes a detector surface with two or more electrodes operating at different electric potentials and coupled to the detector surface; and one or more ion-implanted CZT surfaces on or in the detector surface, each of the one or more ion-implanted CZT surfaces being independently connected to one of the two or more electrodes and the surface of the detector. At least two of the ion-implanted surfaces are in electrical contact.

  3. Pulse-height defect in single-crystal CVD diamond detectors

    Energy Technology Data Exchange (ETDEWEB)

    Beliuskina, O.; Imai, N. [The University of Tokyo, Center for Nuclear Study, Wako, Saitama (Japan); Strekalovsky, A.O.; Aleksandrov, A.A.; Aleksandrova, I.A.; Ilich, S.; Kamanin, D.V.; Knyazheva, G.N.; Kuznetsova, E.A.; Mishinsky, G.V.; Pyatkov, Yu.V.; Strekalovsky, O.V.; Zhuchko, V.E. [JINR, Flerov Laboratory of Nuclear Reactions, Dubna, Moscow Region (Russian Federation); Devaraja, H.M. [Manipal University, Manipal Centre for Natural Sciences, Manipal, Karnataka (India); Heinz, C. [II. Physikalisches Institut, Justus-Liebig-Universitaet Giessen, Giessen (Germany); Heinz, S. [II. Physikalisches Institut, Justus-Liebig-Universitaet Giessen, Giessen (Germany); GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Hofmann, S.; Kis, M.; Kozhuharov, C.; Maurer, J.; Traeger, M. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Pomorski, M. [CEA, LIST, Diamond Sensor Laboratory, CEA/Saclay, Gif-sur-Yvette (France)

    2017-02-15

    The pulse-height versus deposited energy response of a single-crystal chemical vapor deposition (scCVD) diamond detector was measured for ions of Ti, Cu, Nb, Ag, Xe, Au, and of fission fragments of {sup 252} Cf at different energies. For the fission fragments, data were also measured at different electric field strengths of the detector. Heavy ions have a significant pulse-height defect in CVD diamond material, which increases with increasing energy of the ions. It also depends on the electrical field strength applied at the detector. The measured pulse-height defects were explained in the framework of recombination models. Calibration methods known from silicon detectors were modified and applied. A comparison with data for the pulse-height defect in silicon detectors was performed. (orig.)

  4. sPHENIX: The next generation heavy ion detector at RHIC

    Science.gov (United States)

    Campbell, Sarah; sPHENIX Collaboration

    2017-04-01

    sPHENIX is a new collaboration and future detector project at Brookhaven National Laboratory’s Relativistic Heavy Ion Collider (RHIC). It seeks to answer fundamental questions on the nature of the quark gluon plasma (QGP), including its coupling strength and temperature dependence, by using a suite of precision jet and upsilon measurements that probe different length scales of the QGP. This is possible with a full acceptance, |η| superconducting magnet. With the increased luminosity afforded by accelerator upgrades, sPHENIX is going to perform high statistics measurements extending the kinematic reach at RHIC to overlap the LHC’s. This overlap is going to facilitate a better understanding of the role of temperature, density and parton virtuality in QGP dynamics and, specifically, jet quenching. This paper focuses on key future measurements and the current state of the sPHENIX project.

  5. Electron velocity distribution function in a plasma with temperature gradient and in the presence of suprathermal electrons: application to incoherent-scatter plasma lines

    Directory of Open Access Journals (Sweden)

    P. Guio

    Full Text Available The plasma dispersion function and the reduced velocity distribution function are calculated numerically for any arbitrary velocity distribution function with cylindrical symmetry along the magnetic field. The electron velocity distribution is separated into two distributions representing the distribution of the ambient electrons and the suprathermal electrons. The velocity distribution function of the ambient electrons is modelled by a near-Maxwellian distribution function in presence of a temperature gradient and a potential electric field. The velocity distribution function of the suprathermal electrons is derived from a numerical model of the angular energy flux spectrum obtained by solving the transport equation of electrons. The numerical method used to calculate the plasma dispersion function and the reduced velocity distribution is described. The numerical code is used with simulated data to evaluate the Doppler frequency asymmetry between the up- and downshifted plasma lines of the incoherent-scatter plasma lines at different wave vectors. It is shown that the observed Doppler asymmetry is more dependent on deviation from the Maxwellian through the thermal part for high-frequency radars, while for low-frequency radars the Doppler asymmetry depends more on the presence of a suprathermal population. It is also seen that the full evaluation of the plasma dispersion function gives larger Doppler asymmetry than the heat flow approximation for Langmuir waves with phase velocity about three to six times the mean thermal velocity. For such waves the moment expansion of the dispersion function is not fully valid and the full calculation of the dispersion function is needed.

    Key words. Non-Maxwellian electron velocity distribution · Incoherent scatter plasma lines · EISCAT · Dielectric response function

  6. Electron velocity distribution function in a plasma with temperature gradient and in the presence of suprathermal electrons: application to incoherent-scatter plasma lines

    Directory of Open Access Journals (Sweden)

    P. Guio

    1998-10-01

    Full Text Available The plasma dispersion function and the reduced velocity distribution function are calculated numerically for any arbitrary velocity distribution function with cylindrical symmetry along the magnetic field. The electron velocity distribution is separated into two distributions representing the distribution of the ambient electrons and the suprathermal electrons. The velocity distribution function of the ambient electrons is modelled by a near-Maxwellian distribution function in presence of a temperature gradient and a potential electric field. The velocity distribution function of the suprathermal electrons is derived from a numerical model of the angular energy flux spectrum obtained by solving the transport equation of electrons. The numerical method used to calculate the plasma dispersion function and the reduced velocity distribution is described. The numerical code is used with simulated data to evaluate the Doppler frequency asymmetry between the up- and downshifted plasma lines of the incoherent-scatter plasma lines at different wave vectors. It is shown that the observed Doppler asymmetry is more dependent on deviation from the Maxwellian through the thermal part for high-frequency radars, while for low-frequency radars the Doppler asymmetry depends more on the presence of a suprathermal population. It is also seen that the full evaluation of the plasma dispersion function gives larger Doppler asymmetry than the heat flow approximation for Langmuir waves with phase velocity about three to six times the mean thermal velocity. For such waves the moment expansion of the dispersion function is not fully valid and the full calculation of the dispersion function is needed.Key words. Non-Maxwellian electron velocity distribution · Incoherent scatter plasma lines · EISCAT · Dielectric response function

  7. Silicon radiation detectors: materials and applications

    International Nuclear Information System (INIS)

    Walton, J.T.; Haller, E.E.

    1982-10-01

    Silicon nuclear radiation detectors are available today in a large variety of sizes and types. This profusion has been made possible by the ever increasing quality and diameter silicon single crystals, new processing technologies and techniques, and innovative detector design. The salient characteristics of the four basic detector groups, diffused junction, ion implanted, surface barrier, and lithium drift are reviewed along with the silicon crystal requirements. Results of crystal imperfections detected by lithium ion compensation are presented. Processing technologies and techniques are described. Two recent novel position-sensitive detector designs are discussed - one in high-energy particle track reconstruction and the other in x-ray angiography. The unique experimental results obtained with these devices are presented

  8. A BGO detector array and its application in intermediate energy heavy ion experiments

    International Nuclear Information System (INIS)

    Li Zuyu; Jin Genming; He Zhiyong; Duan Limin; Wu Heyu; Qi Yujin; Luo Qingzheng; Zhang Baoguo; Wen Wanxin; Dai Guangxi

    1996-01-01

    A BGO crystal (Bi 4 Ge 3 O 12 ) as the E detector of ΔE-E for identification of reaction products has been used for detecting the charged particles emitting from the 25 MeV 40 Ar induced reaction. The responses of the BGO crystal to various light charged particles were measured. A close-packed hexagonal array consisting of thirteen ΔE-E telescopes (Si-BGO) has been developed to detect the light charged particles interfering with each other in intermediate-energy heavy-ion induced reactions. Some applications of this telescope array are also described. (orig.)

  9. Ion turbulence and thermal transport in laser-produced plasmas

    International Nuclear Information System (INIS)

    Barr, H.C.; Boyd, T.J.M.

    1982-01-01

    In the interaction of high-intensity lasers with target plasmas the transport of thermal energy from the region in which the radiation is absorbed, to the cold dense plasma in the interior of the target, is an issue of central importance. The role of ion turbulence as a flux limiter is addressed with particular regard to recent experiments in which target plasmas were irradiated by 1.06 μm neodymium laser light at irradiances of 10 15 W cm - 2 and greater. Saturation levels of the ion-acoustic turbulence driven by a combination of a suprathermal electron current and a heat flux are calculated on the basis of perturbed orbit theory. The levels of turbulence are found to be markedly lower than those commonly estimated from simple trapping arguments and too low to explain the thermal flux inhibition observed in the experiments used as a basis for the model. (author)

  10. Suprathermal electron production in laser-irradiated Cu targets characterized by combined methods of x-ray imaging and spectroscopy

    Czech Academy of Sciences Publication Activity Database

    Renner, Oldřich; Šmíd, Michal; Batani, D.; Antonelli, L.

    2016-01-01

    Roč. 58, č. 7 (2016), 1-8, č. článku 075007. ISSN 0741-3335 R&D Projects: GA MŠk LQ1606; GA MŠk EF15_008/0000162; GA MŠk(CZ) LD14089 Grant - others:ELI Beamlines(XE) CZ.02.1.01/0.0/0.0/15_008/0000162 Institutional support: RVO:68378271 Keywords : laser- plasma interaction * inertial confinement fusion * suprathermal electron Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 2.392, year: 2016

  11. Investigation of Nuclear Fragmentation in Relativistic Heavy Ion Collisions Using Plastic - Nuclear - Track Detectors

    CERN Multimedia

    2002-01-01

    In this experiment CR39 plastic nuclear track detectors will be used which are sensitive to detect relativistic nuclear fragments with charges Z@$>$5. They will be analyzed using an automatic track measuring system which was developed at the University of Siegen.\\\\ \\\\ This allows to measure large quantities of tracks in these passive detectors and to perform high statistics experiments. We intend to measure cross sections for the production of nuclear fragments from heavy ion beams at the SPS. \\\\ \\\\ The energy independence of the cross sections predicted by the idea of limiting fragmentation will be tested at high energies. In exposures with different targets we plan to analyze the factorization of the fragmentation cross sections into a target depending factor and a factor depending on the beam particle and the fragment. The cross sections for one proton remov Coulomb dissociation. \\\\ \\\\ We plan to investigate Coulomb dissociation for different targets and different energies. Fragment and projectile charges ...

  12. Image timing and detector performance of a matrix ion-chamber electronic portal imaging device

    International Nuclear Information System (INIS)

    Greer, P.

    1996-01-01

    The Oncology Centre of Auckland Hospital recently purchased a Varian PortalVision TM electronic portal imaging device (EPID). Image acquisition times, input-output characteristics and contrast-detail curves of this matrix liquid ion-chamber EPID have been measured to examine the variation in imaging performance with acquisition mode. The variation in detector performance with acquisition mode has been examined. The HV cycle time can be increased to improve image quality. Consideration should be given to the acquisition mode and HV cycle time used when imaging to ensure adequate imaging performance with reasonable imaging time. (author)

  13. CR-39 track detector calibration for H, He, and C ions from 0.1-0.5 MeV up to 5 MeV for laser-induced nuclear fusion product identification.

    Science.gov (United States)

    Baccou, C; Yahia, V; Depierreux, S; Neuville, C; Goyon, C; Consoli, F; De Angelis, R; Ducret, J E; Boutoux, G; Rafelski, J; Labaune, C

    2015-08-01

    Laser-accelerated ion beams can be used in many applications and, especially, to initiate nuclear reactions out of thermal equilibrium. We have experimentally studied aneutronic fusion reactions induced by protons accelerated by the Target Normal Sheath Acceleration mechanism, colliding with a boron target. Such experiments require a rigorous method to identify the reaction products (alpha particles) collected in detectors among a few other ion species such as protons or carbon ions, for example. CR-39 track detectors are widely used because they are mostly sensitive to ions and their efficiency is near 100%. We present a complete calibration of CR-39 track detector for protons, alpha particles, and carbon ions. We give measurements of their track diameters for energy ranging from hundreds of keV to a few MeV and for etching times between 1 and 8 h. We used these results to identify alpha particles in our experiments on proton-boron fusion reactions initiated by laser-accelerated protons. We show that their number clearly increases when the boron fuel is preformed in a plasma state.

  14. Depth sensitivity of Lexan polycarbonate detector

    CERN Document Server

    Awad, E M

    1999-01-01

    The dependence of the registration sensitivity of Lexan polycarbonate with depth inside the detector was studied. Samples of Lexan from General Electric were irradiated to two long range ions. These were Ni and Au ions with a projectile energy of 0.3 and 1 GeV/n. Two independent techniques, the track-diameter technique (TDT) and the track profile technique (TPT), were used. The registration sensitivity was measured at depths of 7, 10, 15, 18, 20, 28, 35 and 40 mu m inside the detector. The results of the two techniques show that the detector sensitivity decreases gradually with the depth inside the detector. It reaches 20 % less compared to sensitivity at the surface after 40 mu m have been removed.

  15. A new compact solid-state neutral particle analyser at ASDEX Upgrade: Setup and physics modeling

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, P. A.; Blank, H.; Geiger, B.; Mank, K.; Martinov, S.; Ryter, F.; Weiland, M.; Weller, A. [Max-Planck-Institut für Plasmaphysik, Garching (Germany)

    2015-07-15

    At ASDEX Upgrade (AUG), a new compact solid-state detector has been installed to measure the energy spectrum of fast neutrals based on the principle described by Shinohara et al. [Rev. Sci. Instrum. 75, 3640 (2004)]. The diagnostic relies on the usual charge exchange of supra-thermal fast-ions with neutrals in the plasma. Therefore, the measured energy spectra directly correspond to those of confined fast-ions with a pitch angle defined by the line of sight of the detector. Experiments in AUG showed the good signal to noise characteristics of the detector. It is energy calibrated and can measure energies of 40-200 keV with count rates of up to 140 kcps. The detector has an active view on one of the heating beams. The heating beam increases the neutral density locally; thereby, information about the central fast-ion velocity distribution is obtained. The measured fluxes are modeled with a newly developed module for the 3D Monte Carlo code F90FIDASIM [Geiger et al., Plasma Phys. Controlled Fusion 53, 65010 (2011)]. The modeling allows to distinguish between the active (beam) and passive contributions to the signal. Thereby, the birth profile of the measured fast neutrals can be reconstructed. This model reproduces the measured energy spectra with good accuracy when the passive contribution is taken into account.

  16. Irradiation of 4H-SiC UV detectors with heavy ions

    International Nuclear Information System (INIS)

    Kalinina, E. V.; Lebedev, A. A.; Bogdanova, E.; Berenquier, B.; Ottaviani, L.; Violina, G. N.; Skuratov, V. A.

    2015-01-01

    Ultraviolet (UV) photodetectors based on Schottky barriers to 4H-SiC are formed on lightly doped n-type epitaxial layers grown by the chemical vapor deposition method on commercial substrates. The diode structures are irradiated at 25°C by 167-MeV Xe ions with a mass of 131 amu at a fluence of 6 × 10 9 cm −2 . Comparative studies of the optical and electrical properties of as-grown and irradiated structures with Schottky barriers are carried out in the temperature range 23–180°C. The specific features of changes in the photosensitivity and electrical characteristics of the detector structures are accounted for by the capture of photogenerated carriers into traps formed due to fluctuations of the conduction-band bottom and valence-band top, with subsequent thermal dissociation

  17. EM-induced processes in heavy ion collisions with the ATLAS detector at the LHC

    CERN Document Server

    Steinberg, Peter; The ATLAS collaboration

    2018-01-01

    Electromagnetic processes provide new tools for studying the partonic structure of nuclei, and possibly for directly probing the quark gluon plasma. Ultra-peripheral heavy ion collisions occur when the nuclei have large impact parameter and interact through photon-induced reactions. These include processes in which an energetic photon emitted by one nucleus resolves the partonic structure of the other and stimulates jet production. Much like deep inelastic scattering, such processes provide a clean probe of the nuclear parton distributions. Jet photo-production represents the most direct opportunity to study nuclear parton distributions until a future electron-ion collider is constructed. This talk presents measurements of ultra-peripheral jet photo-production in Pb+Pb collisions with the ATLAS detector at the LHC. It also presents another application of EM-induced processes, where dimuons produced by gamma-gamma processes are observed to show a centrality-dependent broadening in their opening angle, which ca...

  18. Protons on ions bring new physics to LHCb

    CERN Multimedia

    Antonella Del Rosso

    2013-01-01

    The research opportunities offered by proton-lead collisions at the LHC are generating increasing interest among theorists and experimentalists. During this recent run, LHCb, the asymmetric detector originally designed to study CP asymmetries and rare decays involving heavy quarks, took data with proton and ion beams for the first time. Using these collisions, the experiment can provide a different perspective on specific physics processes, so new developments may be in sight.   A proton-lead ion collision observed by the LHCb detector during the 2013 data taking period. LHCb is a smaller detector than the gigantic multi-purpose CMS and ATLAS detectors. It is also smaller than ALICE, the detector designed in particular to study ion-ion collisions. However, LHCb has something special: it can study physics processes that involve particles scattered from collisions at very small angles and close to the collision point. LHCb does not take data during ion-ion r...

  19. The Lunar Potential Determination Using Apollo-Era Data and Modern Measurements and Models

    Science.gov (United States)

    Collier, Michael R.; Farrell, William M.; Espley, Jared; Webb, Phillip; Stubbs, Timothy J.; Webb, Phillip; Hills, H. Kent; Delory, Greg

    2008-01-01

    Since the Apollo era the electric potential of the Moon has been a subject of interest and debate. Deployed by three Apollo missions, Apollo 12, Apollo 14 and Apollo 15, the Suprathermal Ion Detector Experiment (SIDE) determined the sunlit lunar surface potential to be about +10 Volts using the energy spectra of lunar ionospheric thermal ions accelerated toward the Moon. More recently, the Lunar Prospector (LP) Electron Reflectometer used electron distributions to infer negative lunar surface potentials, primarily in shadow. We will present initial results from a study to combine lunar surface potential measurements from both SIDE and the LP/Electron Reflectometer to calibrate an advanced model of lunar surface charging which includes effects from the plasma environment, photoemission, secondaries ejected by ion impact onto the lunar surface, and the lunar wake created downstream by the solar wind-lunar interaction.

  20. Long-range alpha detector (LRAD)

    International Nuclear Information System (INIS)

    MacArthur, D.W.; McAtee, J.L.

    1991-01-01

    Historically, alpha detectors have been limited by the very short range of alpha particles in air and by relatively poor sensitivity, even if the particles are intercepted. Of necessity, these detectors are operated in a vacuum or in close proximity to the source if reasonable efficiency is desired. In our new long-range alpha detector (LRAD), alpha particles interact with the ambient air, producing ionization in the air at the rate of about 30,000 ion pairs per MeV of alpha energy. These charges can be transported over significant distances (several meters) in a moving current of air generated by a small fan. An ion chamber located in front of the fan measures the current carried by the moving ions. The LRAD-based monitor is more sensitive and more thorough than conventional monitors. We present current LRAD sensitivity limits and results, practical monitor designs, and proposed uses for LRAD monitors. 4 refs., 7 figs

  1. Fundamental processes in the expansion, energization, and coupling of single- and multi-Ion plasmas in space: Laboratory simulation experiments

    Science.gov (United States)

    Szuszczewicz, E. P.; Bateman, T. T.

    1996-01-01

    We have conducted a laboratory investigation into the physics of plasma expansions and their associated energization processes. We studied single- and multi-ion plasma processes in self-expansions, and included light and heavy ions and heavy/light mixtures to encompass the phenomenological regimes of the solar and polar winds and the AMPTE and CRRES chemical release programs. The laboratory experiments provided spatially-distributed time-dependent measurements of total plasma density, temperature, and density fluctuation power spectra with the data confirming the long-theorized electron energization process in an expanding cloud - a result that was impossible to determine in spaceborne experiments (as e.g., in the CRRES program). These results provided the missing link in previous laboratory and spaceborne programs. confirming important elements in our understanding of such solar-terrestrial processes as manifested in expanding plasmas in the solar wind (e.g., CMES) and in ionospheric outflow in plasmaspheric fluctuate refilling after a storm. The energization signatures were seen in an entire series of runs that varied the ion species (Ar', Xe', Kr' and Ne'), and correlative studies included spectral analyses of electrostatic waves collocated with the energized electron distributions. In all cases wave energies were most intense during the times in which the suprathermal populations were present, with wave intensity increasing with the intensity of the suprathermal electron population. This is consistent with theoretical expectations wherein the energization process is directly attributable to wave particle interactions. No resonance conditions were observed, in an overall framework in which the general wave characteristics were broadband with power decreasing with increasing frequency.

  2. Response of CR39 detector to 5 A GeV Si14+ ions and measurement of total charge changing cross-section

    International Nuclear Information System (INIS)

    Gupta, Renu; Kumar, Ashavani

    2013-01-01

    In the present work, response of CR39 track etch detector was obtained by cone-height measurement technique. CR39 track etch detector was used to identify the incident charged particles and their fragments by the measurements of cone-height of tracks using an optical microscope DM6000 M and automated image analyzer system installed with Leica QWin Plus software. The CR39 detector was calibrated and the response points were fitted with a linear relation and all the points are within the limits of the experimental errors. The charge resolution of the detector was calculated to be 0.2e. The response function is obtained and fitted with a linear relation which is good throughout Z/β=6.1–14.1. The experimental value of the total charge changing cross-section of 5 A GeV Si 14+ ion beam in polyethylene and CR39 combined target is σ tot =(734±128) mb. The total charge changing cross-section is compared with the experimental results of others based on cone base-area measurement technique and also fitted by the Bradt–Peters geometrical cross-section. - Highlights: • Charge resolution of 0.2e was obtained by cone-height measurement. • Consistency in manual measurements of cone-heights is presented. • Response of CR39 detector was obtained and fitted with first degree polynomial. • Total charge changing cross-section of 5 A GeV Si 14+ ions in CH 2 and CR39 as a combined target was calculated

  3. Study on Silicon detectors

    International Nuclear Information System (INIS)

    Gervino, G.; Boero, M.; Manfredotti, C.; Icardi, M.; Gabutti, A.; Bagnolatti, E.; Monticone, E.

    1990-01-01

    Prototypes of Silicon microstrip detectors and Silicon large area detectors (3x2 cm 2 ), realized directly by our group, either by ion implantation or by diffusion are presented. The physical detector characteristics and their performances determined by exposing them to different radioactive sources and the results of extensive tests on passivation, where new technological ways have been investigated, are discussed. The calculation of the different terms contributing to the total dark current is reported

  4. Ionisation detectors as monitors of toxic compounds in air

    International Nuclear Information System (INIS)

    Leonhardt, J.W.

    1994-01-01

    Beta particles cause ionisation in gas mixtures. The ions produced provide information on the concentration and identity of trace compounds in ambient air. Modern ionisation detectors use ion mobilities to monitor toxic compounds. Chemical solvent, phosphororganic compounds, PCB and many other toxins can be detected using ion mobility detectors (IMD) in the ppb range or lower. Ion mobility detectors have large potential in industry and research because of their sensitivity, specificity, fast response and relatively low cost. Portable devices and fixed installations are possible. The paper discusses the following topics: (1) ionisation sources in IMD: 63 Ni, 3 H, photoionization and corona discharge, (2) basic principles of ion production, (3) ion collection in IMD, (4) design, gas supply, automatic identification and quantification of IMD data, and (5) selected applications. Advantages and problems with this new type of nuclear analytical instrument are also discussed. (author). 2 refs., 9 figs., 3 tabs

  5. The statistics of foreshock cavities: results of a Cluster survey

    OpenAIRE

    L. Billingham; S. J. Schwartz; D. G. Sibeck

    2008-01-01

    We use Cluster magnetic field, thermal ion, and energetic particle observations upstream of the Earth's bow shock to investigate the occurrence patterns of foreshock cavities. Such cavities are thought to form when bundles of magnetic field connect to the quasi-parallel bow shock. Shock-processed suprathermal ions can then stream along the field, back against the flow of the solar wind. These suprathermals enhance the pressure on shock-connected field lines causing them to expand into th...

  6. QUIET-TIME SUPRATHERMAL (∼0.1–1.5 keV) ELECTRONS IN THE SOLAR WIND

    Energy Technology Data Exchange (ETDEWEB)

    Tao, Jiawei; Wang, Linghua; Zong, Qiugang; He, Jiansen; Tu, Chuanyi [School of Earth and Space Science, Peking University, Beijing 100871 (China); Li, Gang [Department of Physics and CSPAR, University of Alabama in Huntsville, Alabama 35899 (United States); Salem, Chadi S.; Bale, Stuart D. [Space Sciences Laboratory, University of California, Berkeley, CA 94720 (United States); Wimmer-Schweingruber, Robert F., E-mail: wanglhwang@gmail.com [Institute for Experimental and Applied Physics, University of Kiel, Leibnizstrasse 11, D-24118 Kiel (Germany)

    2016-03-20

    We present a statistical survey of the energy spectrum of solar wind suprathermal (∼0.1–1.5 keV) electrons measured by the WIND 3DP instrument at 1 AU during quiet times at the minimum and maximum of solar cycles 23 and 24. After separating (beaming) strahl electrons from (isotropic) halo electrons according to their different behaviors in the angular distribution, we fit the observed energy spectrum of both strahl and halo electrons at ∼0.1–1.5 keV to a Kappa distribution function with an index κ and effective temperature T{sub eff}. We also calculate the number density n and average energy E{sub avg} of strahl and halo electrons by integrating the electron measurements between ∼0.1 and 1.5 keV. We find a strong positive correlation between κ and T{sub eff} for both strahl and halo electrons, and a strong positive correlation between the strahl n and halo n, likely reflecting the nature of the generation of these suprathermal electrons. In both solar cycles, κ is larger at solar minimum than at solar maximum for both strahl and halo electrons. The halo κ is generally smaller than the strahl κ (except during the solar minimum of cycle 23). The strahl n is larger at solar maximum, but the halo n shows no difference between solar minimum and maximum. Both the strahl n and halo n have no clear association with the solar wind core population, but the density ratio between the strahl and halo roughly anti-correlates (correlates) with the solar wind density (velocity)

  7. sPHENIX: The next generation heavy ion detector at RHIC

    International Nuclear Information System (INIS)

    Campbell, Sarah

    2017-01-01

    sPHENIX is a new collaboration and future detector project at Brookhaven National Laboratory’s Relativistic Heavy Ion Collider (RHIC). It seeks to answer fundamental questions on the nature of the quark gluon plasma (QGP), including its coupling strength and temperature dependence, by using a suite of precision jet and upsilon measurements that probe different length scales of the QGP. This is possible with a full acceptance, | η | < 1 and 0-2 π in φ , electromagentic and hadronic calorimeters and precision tracking enabled by a 1.5 T superconducting magnet. With the increased luminosity afforded by accelerator upgrades, sPHENIX is going to perform high statistics measurements extending the kinematic reach at RHIC to overlap the LHC’s. This overlap is going to facilitate a better understanding of the role of temperature, density and parton virtuality in QGP dynamics and, specifically, jet quenching. This paper focuses on key future measurements and the current state of the sPHENIX project. (paper)

  8. Doppler ion program description

    International Nuclear Information System (INIS)

    Henline, P.

    1980-12-01

    The Doppler spectrometer is a conventional Czerny-Turner grating spectrometer with a 1024 channel multiple detector. Light is dispersed across the detector, and its output yields a spectrum covering approximately 200 A. The width of the spectral peak is directly proportional to the temperature of the emitting ions, and determination of the impurity ion temperature allows one to infer the plasma ion temperature. The Doppler ion software system developed at General Atomic uses a TRACOR Northern 1710-31 and an LSI-11/2. The exact configuration of Doublet III is different from TRACOR Northern systems at other facilities

  9. High performance SiC detectors for MeV ion beamsgenerated by intense pulsed laser plasmas

    Czech Academy of Sciences Publication Activity Database

    Cutroneo, M.; Musumeci, P.; Zimbone, M.; Torrisi, L.; La Via, F.; Margarone, Daniele; Velyhan, Andriy; Ullschmied, Jiří; Calcagno, L.

    2013-01-01

    Roč. 28, č. 1 (2013), s. 87-93 ISSN 0884-2914 R&D Projects: GA MŠk ED1.1.00/02.0061; GA MŠk EE.2.3.20.0087 Grant - others:ELI Beamlines(XE) CZ.1.05/1.1.00/02.0061; OP VK 2 LaserGen(XE) CZ.1.07/2.3.00/20.0087 Institutional support: RVO:68378271 ; RVO:61389021 Keywords : silicon carbide * ion detectors * high power laser Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.815, year: 2013

  10. Sub-nanosecond time-of-flight for segmented silicon detectors

    International Nuclear Information System (INIS)

    Souza, R.T. de; Alexander, A.; Brown, K.; Floyd, B.; Gosser, Z.Q.; Hudan, S.; Poehlman, J.; Rudolph, M.J.

    2011-01-01

    Development of a multichannel time-of-flight system for readout of a segmented, ion-passivated, ion-implanted silicon detector is described. This system provides sub-nanosecond resolution (δt∼370ps) even for low energy α particles which deposit E≤7.687MeV in the detector.

  11. CMS Experiment at LHC: Detector Status and Physics Capabilities in Heavy Ion Collisions

    CERN Document Server

    Cali, Ivan Amos

    2009-01-01

    The Large Hadron Collider at CERN will collide lead ions at √ SNN = 5:5 TeV allowing high statistics studies of the dense partonic system with hard probes: heavy quarks and quarkonia with an emphasis on the b and ϒ, high-pT jets, photons, as well as Z0 bosons. The Compact Muon Solenoid (CMS) detectors will allow a wide range of unique measurements in nuclear collisions. The CMS data acquisition system, with its reliance on a multipurpose, high-level trigger system, is uniquely qualified for efficient triggering in high-multiplicity heavy ion events. The excellent calorimeters combined with tracking will allow detailed studies of jets, particularly medium effects on the jet fragmentation function and the energy and pT redistribution of particles within the jet. The large CMS acceptance will allow detailed studies of jet structure in rare γ − jet and Z-jet events. The high resolution tracker will tag b quark jets. The muon chambers combined with tracking will study production of the Z0 , J=ψ and the ϒ f...

  12. Nonlinear dust acoustic waves in a charge varying dusty plasma with suprathermal electrons

    International Nuclear Information System (INIS)

    Tribeche, Mouloud; Bacha, Mustapha

    2010-01-01

    Arbitrary amplitude dust acoustic waves in a dusty plasma with a high-energy-tail electron distribution are investigated. The effects of charge variation and electron deviation from the Boltzmann distribution on the dust acoustic soliton are then considered. The dust charge variation makes the dust acoustic soliton more spiky. The dust grain surface collects less electrons as the latter evolves far away from their thermodynamic equilibrium. The dust accumulation caused by a balance of the electrostatic forces acting on the dust grains is more effective for lower values of the electron spectral index. Under certain conditions, the dust charge fluctuation may provide an alternate physical mechanism causing anomalous dissipation, the strength of which becomes important and may prevail over that of dispersion as the suprathermal character of the plasma becomes important. Our results may explain the strong spiky waveforms observed in auroral plasmas.

  13. Energy Dispersion in Solar Ion Events over 4 Orders of Magnitude: SOHO/COSTEP and Wind/STICS

    Science.gov (United States)

    Kunow, Horst W.; Posner, A.

    2003-07-01

    The ma jority of solar particle events in the COSTEP observational range of 4 75 MeV/n reveals nucleon energy disp ersion (NED), implying a flare-associated particle acceleration mechanism. Towards lower energies, the situation changes somewhat. Only in a minority of solar energetic particle (SEP) events can the effect of NED be followed into the lower keV range. We analyse the reasons for the distinctly different types of particle transport of >10 keV suprathermal up to 100 MeV energetic ions and conclude that the mean free path depends on rigidity.

  14. Suprathermal Electron Generation and Channel Formation by an Ultrarelativistic Laser Pulse in an Underdense Preformed Plasma

    International Nuclear Information System (INIS)

    Malka, G.; Gaillard, R.; Miquel, J.L.; Rousseaux, C.; Bonnaud, G.; Busquet, M.; Lours, L.; Fuchs, J.; Pepin, H.; Fuchs, J.; Amiranoff, F.; Baton, S.D.

    1997-01-01

    Relativistic electrons are produced, with energies up to 20MeV, by the interaction of a high-intensity subpicosecond laser pulse (1 μm , 300 fs , 10 19 W/cm 2 ) with an underdense plasma. Two suprathermal electron populations appear with temperatures of 1 and 3MeV. In the same conditions, the laser beam transmission is increased up to 20% 30%. We observe both features along with the evidence of laser pulse channeling. A fluid model predicts a strong self-focusing of the pulse. Acceleration in the enhanced laser field seems the most likely mechanism leading to the second electron population. copyright 1997 The American Physical Society

  15. Proceedings of the workshop on radiation detector and its application

    International Nuclear Information System (INIS)

    1996-01-01

    This workshop was held from January 23 to 25, 1996 at National Laboratory for High Energy Physics. At the workshop, lectures were given on the development of the single ion detector using MCP in heavy ion microbeam device, the response of MCP to single heavy ion, the response of a superheated liquid drop type detector to low LET radiation, the response characteristics of a CR-39 flight track detector to hydrogen isotopes, the analysis of small nuclear flight tracks on CR-39 with an interatomic force microscope, charge-sensible amplifiers, the signal-processing circuit for position detection, time and depth-resolved measurement of ion tracks in condensed matter, the response of a thin Si detector to electrons, the method of expressing gas-amplifying rate curves in proportional count gas for low temperature, the characteristics of self annihilating streamer by ultraviolet laser, the development of slow positron beam using radioisotopes, the development of a tunnel junction type x-ray detector, the development of the pattern-analyzing system for PIXE spectra, the characteristics of NE213-CaF 2 bond type neutron detector and many others. In this report, the gists of these papers are collected. (K.I.)

  16. Responses and mechanisms of positive electron affinity molecules in the N2 mode of the thermionic ionization detector and the electron-capture detector

    International Nuclear Information System (INIS)

    Jones, C.S.

    1989-01-01

    Very little knowledge has been acquired in the past on the mechanistic pathway by which molecules respond in the N 2 mode of the thermionic ionization detector. An attempt is made here to elucidate the response mechanism of the detector. The basic response mechanisms are known for the electron capture detector, and an attempt is made to identify the certain mechanism by which selected molecules respond. The resonance electron capture rate constant has been believed to be temperature independent, and investigations of the temperature dependence of electron capture responses are presented. Mechanisms for the N 2 mode of the thermionic ionization detector have been proposed by examining the detector response to positive electron affinity molecules and by measurement of the ions produced by the detector. Electron capture mechanisms for selected molecules have been proposed by examining their temperature dependent responses in the electron capture detector and negative ion mass spectra of the samples. In studies of the resonance electron capture rate constant, the relative responses of selected positive electron affinity molecules and their temperature dependent responses were investigated. Positive electron affinity did not guarantee large responses in the N 2 mode thermionic ionization detector. High mass ions were measured following ionization of samples in the detector. Responses in the electron capture detector varied with temperature and electron affinity

  17. Studies of characteristics of triple GEM detector for the ALICE-TPC upgrade

    International Nuclear Information System (INIS)

    Patra, Rajendra Nath; Singaraju, R.N.; Ahammed, Z.; Nayak, T.K.; Biswas, S.

    2015-01-01

    Gas Electron Multiplier (GEM) is a novel gas detector in the field of radiation detection. GEM detectors have tremendous advantages over other types gas detectors like high rate handling capability with high efficiency and very low ion back flow (IBF). These detectors are most suitable for the use in the future experiments in high-energy proton-proton and heavy-ion collisions at the Large Hadron Collider (LHC) at CERN and Facility for Antiproton and Ion Research (FAIR) at GSI. A Large Ion Collider Experiment (ALICE) at the LHC is a dedicated experiment for the study of Quark Gluon Plasma (QGP). In few years, the data taking rate for Pb-Pb collisions will increase by 100 times to 50 KHz. The ALICE Time Projection Chamber (TPC) is the main tracking detector in ALICE. It is planned that by the year 2018, GEM detectors will replace the present readout planes of TPC. The goal of the present study is to characterize the GEM detector to achieve the performance goal of the TPC

  18. Calorimetric low-temperature detectors for low-energy (E≤1 MeV/amu) heavy ions and their first application in the accelerator mass spectroscopy for trace analysis of 236U

    International Nuclear Information System (INIS)

    Kraft-Bermuth, S.

    2004-01-01

    In the thesis presented here, calorimetric low temperature detectors were for the first time applied in accelerator mass spectrometry (AMS) to determine the isotope ratio of 236 U to 238 U in several samples of natural uranium. The detectors consist of a superconducting aluminium film deposited onto a sapphire absorber which is used as thermistor. An energetic heavy ion deposits its kinetic energy as heat in the absorber. The temperature rise is detected by the resistance change of the superconductor. The AMS experiments were performed at the tandem accelerator VERA of the ''Institut fuer Isotopenforschung und Kernphysik'' of the University of Vienna. In an energy range of 10-60 MeV, a relative energy resolution of ΔE/E=7.10 -3 could be achieved, one order of magnitude better than with conventional ionization detectors. Improving thermal and electronic noise yielded in a second experiment for uranium ions with E=17 MeV a relative energy resolution of ΔE/E=4.6.10 -3 . The energy response of the detectors was linear over the whole energy range and independent of the ion mass. Down to a level of 0.1%, no pulse height defect was observed. With the energy resolution obtained it is possible to determine the isotope ratio of 236 U/ 238 U for several samples of natural uranium. With the resolution achieved it is possible furthermore to apply the detectors in several test experiments for direct mass identification of heavy ions using a combined energy/time of flight measurement. In these first tests, a mass resolution of ΔM/M=(8.5-11.0).10 -3 was achieved. In a first test to apply the detectors for detection of so called ''super heavy elements (Z>=112)'', the large dynamic range allowed to identify the reaction products and their alpha decays simultaneously and time dependent. (orig.)

  19. Pershore made CR-39(DOP) as a 1.015 GeV/n 197Au-ion detector

    International Nuclear Information System (INIS)

    Bhattacharyya, D.P.; Chakrabarty, S.; Rakshit, R.; Basu, B.; Pal, P.; Biswas, S.

    1993-01-01

    Pershore made CR-39(DOP) stack was exposed at a zenith angle of 30deg by 197 Au-ions of energy 1.015 GeV/n using LBL BEVALAC beam. The top of the irradiated plate of the stack has been etched in 6.25N NaOH solution at 70degC for one hour. About 1202 cone lengths were optically measured. The estimated etch rate ratio of the incident 197 Au projectile beam in CR-39 has been found to be 27±2. The result has been compared with earlier observation. The charge resolution of the detector has been estimated from the average of double cone lengths and has been found to have a value of (0.58±0.03)e for 197 Au-ions. (orig.)

  20. For high energy heavy ion experiments TPC 4π detector 'Diogene'. What possibilities and what physics

    International Nuclear Information System (INIS)

    Babinet, R.; Cassagnou, Y.; Drouet, M.

    1981-05-01

    'Diogene' is the name of a 4π solid angle detector, based on a Time Projection Chamber (TPC), designed to perform exclusive measurements of charged particles emitted in central collisions of relativistic heavy ions. Exclusive measurements of all charged particles emitted in central collisions of relativistic heavy ions are becoming more and more necessary in this field of nuclear physics in order to answer some crucial questions such as: what is the degree of compression achieved in these collisions. What is the behavior of nuclear matter at high degree of excitation as well as compression. The possibility of handling high multiplicities up to 40 or 60; a momentum measurement of all particles, with not too bad a resolution, up to about 1.5 GeV/c; a good particle identification between π +- , p, d, t ..

  1. Understanding the anisotropic ion distributions within magnetotail dipolarizing flux bundles

    Science.gov (United States)

    Zhou, X.; Runov, A.; Angelopoulos, V.; Birn, J.

    2017-12-01

    Dipolarizing flux bundles (DFBs), earthward-propagating structures with enhanced northward magnetic field (Bz) component, are usually believed to carry a different plasma population from that in the ambient magnetotail plasma sheet. The ion distribution functions within the DFB, however, are recently found to be largely controlled by the ion adiabaticity parameter κ in the ambient plasma sheet outside the DFBs. According to these observations, the ambient κ values of 2-3 usually correspond to a strong perpendicular anisotropy of suprathermal ions within the DFBs, whereas for lower κ values the ions inside the DFBs become more isotropic. Here we utilize a simple, test-particle model to explore the nature of the anisotropy and its dependence on the ambient κ values. We find that the ion anisotropy originates from successive ion reflections and reentries to the DFBs, during which the ions can be consecutively accelerated in the perpendicular direction by the DFB-carried electric field. This acceleration process may be interrupted, however, when the magnetic field lines are highly curved in the ambient plasma sheet. In this case, the ion trajectories are most stochastic outside the DFB region, which makes the reflected ions less likely to return to the DFBs for another cycle of acceleration; as a consequence, the perpendicular ion anisotropy does not appear. Given that the DFB ions are a free energy source for instabilities when they are injected towards Earth, our simple model (that reproduces most observational features on the anisotropic DFB ion distributions) may shed new lights on the coupling process between the magnetotail and the inner magneosphere.

  2. YAP:Ce and CsI(Tl) detectors for dielectronic recombination experiment at the CSRm

    International Nuclear Information System (INIS)

    Wen, W.Q.; Ma, X.; Xu, W.Q.; Meng, L.J.; Zhu, X.L.; Gao, Y.; Wang, S.L.; Zhang, P.J.; Zhao, D.M.; Liu, H.P.; Zhu, L.F.; Yang, X.D.; Li, J.; Ma, X.M.; Yan, T.L.; Yang, J.C.; Yuan, Y.J.; Xia, J.W.; Xu, H.S.; Xiao, G.Q.

    2013-01-01

    Highlights: • YAP:Ce and CsI(Tl) scintillation detectors are developed to detect heavy ions at the storage ring. • A high count rate of ∼10 7 s −1 is obtained with the YAP:Ce detector for heavy ion detection. • YAP:Ce detector shows good performance for DR experiment with 3.7 MeV/u 112 Sn 35+ . -- Abstract: The storage ring CSRm in Lanzhou provides good possibilities for electron-ion collision studies with cooled ion beams. To carry on the recombination experiment at the CSRm, a scintillation detector CsI(Tl) to detect the recombined ions was developed and tested. In addition, a YAP:Ce detector has been developed and installed at CSRm and capability of handling a high count rate of ∼10 7 s −1 has been obtained which is sufficient for the future dielectronic recombination experiment at the CSRm. The comparison of the characteristics of these two detectors is presented

  3. Co-visualization of DNA damage and ion traversals in live mammalian cells using a fluorescent nuclear track detector

    International Nuclear Information System (INIS)

    Kodaira, Satoshi; Konishi, Teruaki; Kobayashi, Alisa

    2015-01-01

    The geometric locations of ion traversals in mammalian cells constitute important information in the study of heavy ion-induced biological effect. Single ion traversal through a cellular nucleus produces complex and massive DNA damage at a nanometer level, leading to cell inactivation, mutations and transformation. We present a novel approach that uses a fluorescent nuclear track detector (FNTD) for the simultaneous detection of the geometrical images of ion traversals and DNA damage in single cells using confocal microscopy. HT1080 or HT1080–53BP1-GFP cells were cultured on the surface of a FNTD and exposed to 5.1-MeV/n neon ions. The positions of the ion traversals were obtained as fluorescent images of a FNTD. Localized DNA damage in cells was identified as fluorescent spots of γ-H2AX or 53BP1-GFP. These track images and images of damaged DNA were obtained in a short time using a confocal laser scanning microscope. The geometrical distribution of DNA damage indicated by fluorescent γ-H2AX spots in fixed cells or fluorescent 53BP1-GFP spots in living cells was found to correlate well with the distribution of the ion traversals. This method will be useful for evaluating the number of ion hits on individual cells, not only for micro-beam but also for random-beam experiments. (author)

  4. Diallyl phthalate (DAP) solid state nuclear track detector

    CERN Document Server

    Koguchi, Y; Ashida, T; Tsuruta, T

    2003-01-01

    Diallyl phthalate (DAP) solid state nuclear track detector is suitable for detecting heavy ions such as fission fragments, because it is insensitive to right ions such as alpha particles and protons. Detection efficiency of fission tracks is about 100%, which is unaffected under conditions below 240degC lasting for 1h or below 1 MGy of gamma-ray irradiation. Optimum etching condition for the DAP detector for detection of fission fragments is 2-4 h using 30% KOH aqueous solution at 90degC or 8-15 min using PEW-65 solution at 60degC. DAP detector is useful in detecting induced fission tracks for dating of geology or measuring intense heavy ions induced by ultra laser plasma. The fabrication of copolymers of DAP and CR-39 makes it possible to control the discrimination level for detection threshold of heavy ions. (author)

  5. Methods of manufacturing a detector device

    International Nuclear Information System (INIS)

    Wotherspoon, J.T.M.

    1982-01-01

    In the manufacture of an infra-red radiation detector device, a body of rho-type cadmium mercury telluride is bombarded with ions to etch away a part of the body and to produce from the etched-away part of the body an excess concentration of mercury which acts as a dopant source converting an adjacent part of the body into n-type material. The energy of the bombarding ions is less than 30 keV, and by appropriately choosing the ion dose this conversion can be effected over a depth considerably greater than the penetration depth of the ions. A p-n junction can be fabricated in this way for a photovoltaic detector. The conductivity type conversion may even be effected through the body thickness. The etching and conversion can be localised by masking part of the body surface against the ion bombardment. (author)

  6. Epitaxial silicon semiconductor detectors, past developments, future prospects

    International Nuclear Information System (INIS)

    Gruhn, C.R.

    1976-01-01

    A review of the main physical characteristics of epitaxial silicon as it relates to detector development is presented. As examples of applications results are presented on (1) epitaxial silicon avalanche diodes (ESAD); signal-to-noise, non-linear aspects of the avalanche gain mechanism, gain-bandwidth product, (2) ultrathin epitaxial silicon surface barrier (ESSB) detectors, response to heavy ions, (3) an all-epitaxial silicon diode (ESD), response to heavy ions, charge transport and charge defect. Future prospects of epitaxial silicon as it relates to new detector designs are summarized

  7. The Acceleration of Thermal Protons and Minor Ions at a Quasi-Parallel Interplanetary Shock

    Science.gov (United States)

    Giacalone, J.; Lario, D.; Lepri, S. T.

    2017-12-01

    We compare the results from self-consistent hybrid simulations (kinetic ions, massless fluid electrons) and spacecraft observations of a strong, quasi-parallel interplanetary shock that crossed the Advanced Composition Explorer (ACE) on DOY 94, 2001. In our simulations, the un-shocked plasma-frame ion distributions are Maxwellian. Our simulations include protons and minor ions (alphas, 3He++, and C5+). The interplanetary shock crossed both the ACE and the Wind spacecraft, and was associated with significant increases in the flux of > 50 keV/nuc ions. Our simulation uses parameters (ion densities, magnetic field strength, Mach number, etc.) consistent with those observed. Acceleration of the ions by the shock, in a manner similar to that expected from diffusive shock acceleration theory, leads to a high-energy tail in the distribution of the post-shock plasma for all ions we considered. The simulated distributions are directly compared to those observed by ACE/SWICS, EPAM, and ULEIS, and Wind/STICS and 3DP, covering the energy range from below the thermal peak to the suprathermal tail. We conclude from our study that the solar wind is the most significant source of the high-energy ions for this event. Our results have important implications for the physics of the so-called `injection problem', which will be discussed.

  8. A new ion detector array and digital-signal-processor-based interface

    International Nuclear Information System (INIS)

    Langstaff, D.P.; McGinnity, T.M.; Forbes, D.M.; Birkinshaw, K.; Lawton, M.W.

    1994-01-01

    A new one-dimensional ion detector array on a silicon chip has been developed for use in mass spectrometry. It is much smaller and simpler than electro-optical arrays currently in use and in addition has a higher resolution and a zero noise level. The array consists of a one-dimensional array of metal strips (electrodes) with a pitch of 25 μm on the top surface of a silicon chip, each electrode having its own charge pulse sensor, 8-bit counter and control/interface circuitry. The chip is mounted on a ceramic substrate and is preceded by a micro-channel plate electron multiplier. Chips are butted to give a longer array. Test results show a stable operating region. A digital-signal-processor-based interface is described, which controls the mode of operation and reads the accumulated array data at the maximum rate to avoid counter overflow. (author)

  9. A new ion detector array and digital-signal-processor-based interface

    Energy Technology Data Exchange (ETDEWEB)

    Langstaff, D.P.; McGinnity, T.M.; Forbes, D.M.; Birkinshaw, K. (University Coll. of Wales, Aberystwyth (United Kingdom). Dept. of Physics); Lawton, M.W. (University of Wales Aberystwyth (United Kingdom). Dept. of Computer Science)

    1994-04-01

    A new one-dimensional ion detector array on a silicon chip has been developed for use in mass spectrometry. It is much smaller and simpler than electro-optical arrays currently in use and in addition has a higher resolution and a zero noise level. The array consists of a one-dimensional array of metal strips (electrodes) with a pitch of 25 [mu]m on the top surface of a silicon chip, each electrode having its own charge pulse sensor, 8-bit counter and control/interface circuitry. The chip is mounted on a ceramic substrate and is preceded by a micro-channel plate electron multiplier. Chips are butted to give a longer array. Test results show a stable operating region. A digital-signal-processor-based interface is described, which controls the mode of operation and reads the accumulated array data at the maximum rate to avoid counter overflow. (author).

  10. Stable isotope ratiometer-multiple ion detector (SIRMID) unit for quantitative and qualitative stable isotope studies by gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    Klein, P.D.; Haumann, J.R.; Hachey, D.L.

    1975-01-01

    A stable isotope ratiometer-multiple ion detector (SIRMID) unit which can drive existing gas chromatograph-quadrupole or magnetic sector mass spectrometers to monitor up to six ions in turn is described. Each of the three pairs of ions can be selected for quantitation; thus three different or successive components can be analyzed in a single GC run. A background subtraction option permits the ion intensity in the absence of sample to be subtracted automatically during sample measurement. Displays of accumulated counts and isotope ratio are updated twice per second during the measurement and can be printed out at its conclusion. All six ions can be monitored in the analog mode by parallel outputs to a multipen recorder. Experience gained in the construction of this prototype indicates that SIRMID units could be commercially available for $10K, or about 1 / 3 rd to 1 / 6 th of the cost of even an inexpensive computer system. (U.S.)

  11. ENERGETIC NEUTRAL ATOMS: AN ADDITIONAL SOURCE FOR HELIOSPHERIC PICKUP IONS

    International Nuclear Information System (INIS)

    Bochsler, Peter; Moebius, Eberhard

    2010-01-01

    Recently, Schwadron and McComas discussed the possibility of inner source pickup particles originating from the ionization of energetic neutral atoms (ENAs), based on new data from the IBEX mission. This proposition has some interesting features, namely, it might be able to explain why inner source pickup ions (PUIs) have a composition resembling solar abundances and show no indication of overabundance of refractory elements, although this should be expected, if the conventional explanation of solar wind-dust interaction for the origin of this heliospheric component were correct. In this Letter, we explore further consequences for ENA-related PUIs and investigate their velocity distributions. We conclude that this model will not reproduce the observed velocity distributions of inner source PUIs and point out a substantial deviation in their composition. However, it seems likely that the ionization of ENAs as observed with IBEX could contribute a significant amount of heliospheric suprathermal tail ions. Some possible consequences of our investigation for heliospheric particle populations are briefly discussed.

  12. Microwave heating and diagnostic of suprathermal electrons in an overdense stellarator plasma

    International Nuclear Information System (INIS)

    Stange, Torsten

    2014-01-01

    The resonant coupling of microwaves into a magnetically confined plasma is one of the fundamental methods for the heating of such plasmas. Identifying and understanding the processes of the heating of overdense plasmas, in which the wave propagation is generally not possible because the wave frequency is below the plasma frequency, is becoming increasingly important for high density fusion plasmas. This work focuses on the heating of overdense plasmas in the WEGA stellarator. The excitation of electron Bernstein waves, utilizing the OXB-conversion process, provides a mechanism for the wave to reach the otherwise not accessible resonant absorption layer. In WEGA these OXB-heated plasmas exhibit a suprathermal electron component with energies up to 80 keV. The fast electrons are located in the plasma center and have a Maxwellian energy distribution function within the soft X-ray related energy range. The corresponding averaged energy is a few keV. The OXB-discharges are accompanied by a broadband microwave radiation spectrum with radiation temperatures of the order of keV. Its source was identified as a parametric decay of the heating wave and has no connection to the suprathermal electron component. For the detailed investigation of the microwave emission, a quasioptical mirror system, optimized for the OX-conversion, has been installed. Based on the measurement of the broadband microwave stray radiation of the decay process, the OX-conversion efficiency has been determined to 0.56 being in good agreement with full-wave calculations. In plasmas without an electron cyclotron resonance, corresponding to the wave frequency used, non-resonant heating mechanisms have been identified in the overdense plasma regions. Whistler waves or R-like waves are the only propagable wave types within the overdense plasmas. The analysis of the heating efficiency in dependence on the magnetic flux density leads to tunneling as the most probable coupling mechanism. For the determination

  13. Measurement of ion beam angular distribution at different helium gas pressures in a plasma focus device by large-area polycarbonate detectors

    Energy Technology Data Exchange (ETDEWEB)

    Sohrabi, M.; Habibi, M., E-mail: mortezahabibi@gmail.com; Ramezani, V. [Amirkabir University of Technology, Energy Engineering and Physics Department (Iran, Islamic Republic of)

    2017-02-15

    The paper presents an experimental study and analysis of full helium ion density angular distributions in a 4-kJ plasma focus device (PFD) at pressures of 10, 15, 25, and 30 mbar using large-area polycarbonate track detectors (PCTDs) (15-cm etchable diameter) processed by 50-Hz-HV electrochemical etching (ECE). Helium ion track distributions at different pressures, in particular, at the main axis of the PFD are presented. Maximum ion track density of ~4.4 × 10{sup 4} tracks/cm{sup 2} was obtained in the PCTD placed 6 cm from the anode. The ion distributions for all pressures applied are ring-shaped, which is possibly due to the hollow cylindrical copper anode used. The large-area PCTD processed by ECE proves, at the present state-of-theart, a superior method for direct observation and analysis of ion distributions at a glance with minimum efforts and time. Some observations of the ion density distributions at different pressures are reported and discussed.

  14. A hybrid model for computing nonthermal ion distributions in a long mean-free-path plasma

    Science.gov (United States)

    Tang, Xianzhu; McDevitt, Chris; Guo, Zehua; Berk, Herb

    2014-10-01

    Non-thermal ions, especially the suprathermal ones, are known to make a dominant contribution to a number of important physics such as the fusion reactivity in controlled fusion, the ion heat flux, and in the case of a tokamak, the ion bootstrap current. Evaluating the deviation from a local Maxwellian distribution of these non-thermal ions can be a challenging task in the context of a global plasma fluid model that evolves the plasma density, flow, and temperature. Here we describe a hybrid model for coupling such constrained kinetic calculation to global plasma fluid models. The key ingredient is a non-perturbative treatment of the tail ions where the ion Knudsen number approaches or surpasses order unity. This can be sharply constrasted with the standard Chapman-Enskog approach which relies on a perturbative treatment that is frequently invalidated. The accuracy of our coupling scheme is controlled by the precise criteria for matching the non-perturbative kinetic model to perturbative solutions in both configuration space and velocity space. Although our specific application examples will be drawn from laboratory controlled fusion experiments, the general approach is applicable to space and astrophysical plasmas as well. Work supported by DOE.

  15. IBIC characterisation of novel detectors for single atom doping of quantum computer devices

    International Nuclear Information System (INIS)

    Yang Changyi; Jamieson, David N.; Pakes, Chris I.; George, Damien P.; Hearne, Sean M.; Dzurak, Andrew S.; Gauja, Eric; Stanley, F.; Clark, R.G.

    2003-01-01

    Single ion implantation and online detection is highly desirable for the emerging application, in which single 31 P ions need to be inserted in prefabricated silicon cells to construct solid-state quantum bits (qubits). In order to fabricate qubit arrays, we have developed novel detectors that employ detector electrodes adjacent to the prefabricated cells that can detect single keV ion strikes appropriate for the fabrication of shallow phosphorus arrays. The method utilises a high purity silicon substrate with very high resistivity, a thin SiO 2 surface layer, nanometer masks for the lateral positioning single phosphorus implantation, biased electrodes applied to the surface of the silicon and sensitive electronics that can detect the charge transient from single keV ion strikes. A TCAD (Technology Computer Aided Design) software package was applied in the optimisation of the device design and simulation of the detector performance. Here we show the characterisation of these detectors using ion beam induced charge (IBIC) with a focused 2 MeV He ions in a nuclear microprobe. The IBIC imaging method in a nuclear microprobe allowed us to measure the dead-layer thickness of the detector structure (required to be very thin for successful detection of keV ions), and the spatial distribution of the charge collection efficiency around the entire region of the detector. We show that our detectors have near 100% charge collection efficiency for MeV ions, extremely thin dead-layer thickness (about 7 nm) and a wide active region extending laterally from the electrodes (10-20 μm) where qubit arrays can be constructed. We demonstrate that the device can be successfully applied in the detection of keV ionisation energy from single events of keV X-rays and keV 31 P ions

  16. IBIC characterisation of novel detectors for single atom doping of quantum computer devices

    Energy Technology Data Exchange (ETDEWEB)

    Yang Changyi E-mail: cjy@physics.unimelb.edu.auc.yang@physics.unimelb.edu.au; Jamieson, David N.; Pakes, Chris I.; George, Damien P.; Hearne, Sean M.; Dzurak, Andrew S.; Gauja, Eric; Stanley, F.; Clark, R.G

    2003-09-01

    Single ion implantation and online detection is highly desirable for the emerging application, in which single {sup 31}P ions need to be inserted in prefabricated silicon cells to construct solid-state quantum bits (qubits). In order to fabricate qubit arrays, we have developed novel detectors that employ detector electrodes adjacent to the prefabricated cells that can detect single keV ion strikes appropriate for the fabrication of shallow phosphorus arrays. The method utilises a high purity silicon substrate with very high resistivity, a thin SiO{sub 2} surface layer, nanometer masks for the lateral positioning single phosphorus implantation, biased electrodes applied to the surface of the silicon and sensitive electronics that can detect the charge transient from single keV ion strikes. A TCAD (Technology Computer Aided Design) software package was applied in the optimisation of the device design and simulation of the detector performance. Here we show the characterisation of these detectors using ion beam induced charge (IBIC) with a focused 2 MeV He ions in a nuclear microprobe. The IBIC imaging method in a nuclear microprobe allowed us to measure the dead-layer thickness of the detector structure (required to be very thin for successful detection of keV ions), and the spatial distribution of the charge collection efficiency around the entire region of the detector. We show that our detectors have near 100% charge collection efficiency for MeV ions, extremely thin dead-layer thickness (about 7 nm) and a wide active region extending laterally from the electrodes (10-20 {mu}m) where qubit arrays can be constructed. We demonstrate that the device can be successfully applied in the detection of keV ionisation energy from single events of keV X-rays and keV {sup 31}P ions.

  17. Proceedings of the third workshop on experiments and detectors for a relativistic heavy ion collider (RHIC)

    International Nuclear Information System (INIS)

    Shivakumar, B.; Vincent, P.

    1988-01-01

    This report contains papers on the following topics: the RHIC Project; summary of the working group on calorimetry; J//Psi/ measurements in heavy ion collisions at CERN; QCD jets at RHIC; tracking and particle identification; a 4π tracking spectrometer for RHIC; Bose-Einstein measurements at RHIC in light of new data; summary of working group on read-out electronics; data acquisition for RHIC; summary of the working group on detector simulation; B-physics at RHIC; and CP violation revisited at BNL, B-physics at RHIC

  18. Zeroing and testing units developed for Gerdien atmospheric ion detectors

    International Nuclear Information System (INIS)

    Kolarz, P.; Marinkovic, B.P.; Filipovic, D.M.

    2005-01-01

    Low current measurements in atmospheric ion detection using a Gerdien condenser are subjected to numerous sources of error. Zeroing and testing units described in this article, connected as modules to this type of detector, enable some of these errors to be found and eliminated. The zeroing unit provides digital compensation of the zero drift with a digital sample and hold circuit of 12-bit resolution. It overcomes difficulties related to zero drift and techniques used in the zero conductivity determination when the accelerating potential or airflow rate are zero. The testing unit is a current reference of nominally 10 -12 A intended for testing and correcting the system on current leakage and other measuring deviations due to changes in atmospheric parameters. This unit is an independent battery-powered module, which provides a charge of 10 -12 C per cycle (frequency of order 1 Hz) to the collecting electrode. The control of Gerdien devices is substantially simplified using the zeroing and testing units realized here. Both units are used during 'zero conductivity' regime only

  19. Use of a new ion-detector in the study of the jet plasma injected into a pulsed magnetic mirror configuration (deca I); Utilisation d'un nouveau detecteur d'ions dans l'etude du jet de plasma injecte dans deca I

    Energy Technology Data Exchange (ETDEWEB)

    Renaud, C [Association Euratom-CEA Cadarache, Groupe de Recherches sur la Fusion Controlee, 13 - Saint-Paul-lez-Durance (France). Centre d' Etudes Nucleaires

    1963-07-01

    The study of a high sensitivity ion detector coupled to an electrostatic analyser has permitted a large investigation of the plasma jet injected into a pulsed magnetic mirror configuration. In this detector the positive ions are accelerated through a potential of 30 kV; they strike a metallic target, on which they produce secondary electrons; these, in turn, are accelerated onto a plastic scintillator. The light pulses are detected with a photomultiplier. The gain of this device is about 10{sup 7}. If we make an admission of air into the vacuum system and again we make vacuum, the gain is not modified, since no special activated surfaces are situated in the detector. (author) [French] L'etude d'un detecteur d'ions de grande sensibilite, allie a un analyseur electrostatique a permis une investigation approfondie du jet de plasma injecte dans le dispositif d'Etude de Compression Adiabatique. Dans ce detecteur, les ions positifs sont acceleres par une difference de potentiel voisine de 30 kV, ils bombardent une cible metallique et creent des electrons secondaires qui sont a leur tour acceleres vers un scintillateur plastique. Les impulsions lumineuses sont alors detectees par un photomultiplicateur. Le gain obtenu pour l'ensemble du detecteur est voisin de 10{sup 7}. Le detecteur ne possedant pas de surfaces specialement activees, les remises a l'air n'entrainent pas de variation de gain. (auteur)

  20. Introduction to detectors

    CERN Document Server

    Walenta, Albert H

    1995-01-01

    Concepts for momentum measurements,particle identification and energy measurements (calorimeters) as well for imaging applications in medecine, biology and industry (non destructive testing) will be put into relation to the specific detection princip In particular the resolution for position, time, energy and intensity measurement and the efficiency will be discussed. Signal extraction,electronic signal processing and principles of information capture will close the logic circle to the input : the radiation properties.The lecture will provide some sources for data tables and small demonstration computer programs f The basic detector physics as interaction of radiation with matter, information transport via free charges,photons and phonons and the signal formation will be presented in some depth with emphasis on the influence on specific parameters for detector The lecture will cover the most popular detector principles, gas detectors (ion chambers,MPWC's and MSGC's), semiconductor detectors scintillators and ...

  1. MUPPATS: a multiparticle 3D imaging detector system

    International Nuclear Information System (INIS)

    Faibis, A.; Koenig, W.; Kanter, E.P.; Vager, Z.

    1985-01-01

    It has long been recognized that the foil-induced dissociation of fast molecular ions is a potentially powerful method to determine the stereochemical structures of the molecular projectiles. We have recently developed a detector system specifically designed for such experiments. The MUPPATS detector is a large-area multistep low pressure gas counter. The requirements of multiparticle detection with good position and time resolution leads to a rather complex data-readout and reduction scheme. The system relies on several state-of-the-art techniques, developed in high-energy physics during recent years, to dramatically reduce the cost of the MUPPATS detector. Preliminary results for several polyatomic molecular ions have already been obtained. Some new avenues of research opened up by this detector are also described

  2. TRIO (Triplet Ionospheric Observatory) Mission

    Science.gov (United States)

    Lee, D.; Seon, J.; Jin, H.; Kim, K.; Lee, J.; Jang, M.; Pak, S.; Kim, K.; Lin, R. P.; Parks, G. K.; Halekas, J. S.; Larson, D. E.; Eastwood, J. P.; Roelof, E. C.; Horbury, T. S.

    2009-12-01

    Triplets of identical cubesats will be built to carry out the following scientific objectives: i) multi-observations of ionospheric ENA (Energetic Neutral Atom) imaging, ii) ionospheric signature of suprathermal electrons and ions associated with auroral acceleration as well as electron microbursts, and iii) complementary measurements of magnetic fields for particle data. Each satellite, a cubesat for ion, neutral, electron, and magnetic fields (CINEMA), is equipped with a suprathermal electron, ion, neutral (STEIN) instrument and a 3-axis magnetometer of magnetoresistive sensors. TRIO is developed by three institutes: i) two CINEMA by Kyung Hee University (KHU) under the WCU program, ii) one CINEMA by UC Berkeley under the NSF support, and iii) three magnetometers by Imperial College, respectively. Multi-spacecraft observations in the STEIN instruments will provide i) stereo ENA imaging with a wide angle in local times, which are sensitive to the evolution of ring current phase space distributions, ii) suprathermal electron measurements with narrow spacings, which reveal the differential signature of accelerated electrons driven by Alfven waves and/or double layer formation in the ionosphere between the acceleration region and the aurora, and iii) suprathermal ion precipitation when the storm-time ring current appears. In addition, multi-spacecraft magnetic field measurements in low earth orbits will allow the tracking of the phase fronts of ULF waves, FTEs, and quasi-periodic reconnection events between ground-based magnetometer data and upstream satellite data.

  3. A high reliability automatic multiplier for a mass spectrometer ion detector circuit

    International Nuclear Information System (INIS)

    Hoshino, Kiichi; Satooka, Sakae

    1978-01-01

    An automatic multiplier of an ion detector circuit for measurement of isotopic abundance ratio of heavy hydrogen to be used with a single collector has been constructed. This multiplier works at 1/1, 1/5, 1/20, 1/100, 1/500, 1/2000 and infinity, and the input voltage which is required to change the range from 1/1 to 1/5 is 10 mV and that from 1/2000 to infinity is 20 V. As the amplifier preceding the automatic multiplier, a vibrating reed electrometer which generates maximum output of 30 V is used. On measurement, marks which indicate the magnifications are recorded on the chart of electronic recorder. It is possible to set the minimum magnification at 1/1, 1/5, or 1/20 by a switch for setting the minimum magnification. (author)

  4. ANTHEM: a two-dimensional multicomponent self-consistent hydro-electron transport code for laser-matter interaction studies

    International Nuclear Information System (INIS)

    Mason, R.J.

    1982-01-01

    The ANTHEM code for the study of CO 2 -laser-generated transport is outlined. ANTHEM treats the background plasma as coupled Eulerian thermal and ion fluids, and the suprathermal electrons as either a third fluid or a body of evolving collisional PIC particles. The electrons scatter off the ions; the suprathermals drag against the thermal background. Self-consistent E- and B-fields are computed by the Implicit Moment Method. The current status of the code is described. Typical output from ANTHEM is discussed with special application to Augmented-Return-Current CO 2 -laser-driven targets

  5. SILICON DRIFT DETECTORS FOR THE STAR/SVT EXPERIMENT AT RHIC

    International Nuclear Information System (INIS)

    TAKAHASHI, J.

    1998-01-01

    Large area linear Silicon Drift Detectors (SDD) were developed to be used in the Silicon Vertex Tracker (SVT) of the STAR experiment at the BNL relativistic heavy ion collider (RHIC). The SDD is in its final design and has been submitted for large scale production. Test results show that the detector exhibits excellent position resolution and low noise. A special characterization procedure was developed to test detector wafers in order to select good detectors for the SVT. Recently, 15 STAR/SVT SDD's were assembled as a tracking device in a BNL-AGS heavy ion experiment (E896). It is the first tracking application of these detectors and their corresponding front-end electronics in an experimental environment. Preliminary results indicating good detector performance are shown and discussed in this paper

  6. Preliminary research results for parameter diagnostics of intense pulsed ion beams

    International Nuclear Information System (INIS)

    Yang Hailiang; Qiu Aici; Sun Jianfeng; He Xiaoping; Tang Junping; Wang Haiyang; Li Jingya; Ren Shuqing; Huang Jianjun; Zhang Jiasheng; Peng Jianchang; Ouyang Xiaoping; Zhang Guoguang; Li Hongyu

    2004-01-01

    The preliminary experimental results for parameter diagnostics of intense pulsed ion beams from the FLASH II accelerator were reported. The ion number of an intense pulsed ion beam were experimentally determined by monitoring delayed radioactivity from protons induced nuclear reactions in a 12 C target. The prompt γ-rays and diode Bremsstrahlung X-rays were measured with PIN semi-conductor detector and a ST401 plastic scintillator detector. The Bremsstrahlung distribution outside of the drift tube was detected with a thermoluminescent detector and the shielding design was also determined. The current densities of beam were measured with biased ion collector array. The ion beams were also recorded with a CR-39 detector. (author)

  7. Long-range alpha detector for contamination monitoring

    International Nuclear Information System (INIS)

    MacArthur, D.W.; Allander, K.S.; McAtee, J.L.

    1991-01-01

    Historically, alpha detectors have been limited by the very short range of alpha particles in air and by relatively poor sensitivity, even if the particles are intercepted. Of necessity, these detectors are operated in a vacuum or in close proximity to the source if reasonable efficiency is desired. In our new long-range alpha detector (LRAD), alpha particles interact with the ambient air, producing ionization in the air at the rate of about 30,000 ion pairs per MeV of alpha energy. These charges can be transported over significant distances (several meters) in a moving current of air generated by a small fan. An ion chamber located in front of the fan measures the current carried by the moving ions. The LRAD-based monitor is more sensitive and more thorough than conventional monitors. We present current LRAD sensitivity limits and results, practical monitor designs, and proposed uses for LRAD monitors. 4 refs., 6 figs

  8. Radon monitoring using long-range alpha detector-based technology

    International Nuclear Information System (INIS)

    Bolton, R.D.

    1994-01-01

    Long-Range Alpha Detector (LRAD) technology is being studied for monitoring radon gas concentrations. LRAD-based instruments collect and measure the ionization produced in air by alpha decays. These ions can be moved to a collection grid via electrostatic ion-transport design collected approximately 95% of the radon produced ions, while instruments using an airflow transport design collected from 44% to 77% of these ions, depending on detector geometry. The current produced by collecting this ionization is linear with respect to 222 Rn concentration over the available test range of 0.07 to 820 pCi/L. In the absence of statistical limitations due to low radon concentrations, the speed of response of LRAD-based instruments is determined by the air exchange rate, and therefore changes in radon concentration can be detected in just a few seconds. Recent tests show that at radon concentrations below 20 pCi/L current pulses produced by individual alpha decays can be counted, thus improving detector sensitivity and stability even further. Because these detectors are simple, rugged, and do not consume much power, they are natural candidates for portable, battery operation

  9. The Multi-Purpose Detector (MPD) of the collider experiment

    Energy Technology Data Exchange (ETDEWEB)

    Golovatyuk, V.; Kekelidze, V.; Kolesnikov, V.; Rogachevsky, O. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Sorin, A. [Joint Institute for Nuclear Research, Dubna (Russian Federation); National Research Nuclear University (MEPhI), Moscow (Russian Federation)

    2016-08-15

    The project NICA (Nuclotron-based Ion Collider fAcility) is aimed to study dense baryonic matter in heavy-ion collisions in the energy range up to √(s{sub NN}) = 11 GeV with average luminosity of L = 10{sup 27} cm{sup -2}s{sup -1} (for {sup 197}Au{sup 79}). The experimental program at the NICA collider will be performed with the Multi-Purpose Detector (MPD). We report on the main physics objectives of the NICA heavy-ion program and present the main detector components. (orig.)

  10. Detector performance tests for the CBM TRD

    Energy Technology Data Exchange (ETDEWEB)

    Kohn, Martin [Institut fuer Kernphysik, WWU Muenster (Germany)

    2016-07-01

    The Compressed Baryonic Matter (CBM) experiment is a fixed target heavy-ion experiment at the future FAIR accelerator facility. The CBM Transition Radiation Detector (TRD) is one of the key detectors to provide electron identification and charged particle tracking. With the construction phase of the detector nearing, we will present results of the detector obtained with a close to final prototype. These results were achieved in measurements at CERN PS in 2014 and SPS in 2015.

  11. Coordinate-sensitive charged particle detector for spectroscopy

    Directory of Open Access Journals (Sweden)

    Sidorenko V. P.

    2016-10-01

    Full Text Available The authors have designed, manufactured and tested a coordinate-sensitive detector for charged particle spectroscopy. The detector can be used in the devices for the elemental analysis of materials, providing simultaneous analysis of all the elemental composition with high sensitivity and precision. The designed device is based on an integrated circuit (IC and a microchannel plate (MCP electron multiplier. The IC is mounted on a ceramic substrate. Ions fall on the MCP mounted above the IC. Giving rise to a pulse which typically exceeds 106 electrons, each ion falls on the detector electrodes and these pulses are counted. In this research, a two stage stack of MCPs (Hamamatsu was used. The MCPs have a channel diameter of 12 μm on a 15 μm pitch. The results of tests carried out in a mass spectrometer are presented. The designed detector is small, light, and low-power.

  12. Cluster secondary ion mass spectrometry microscope mode mass spectrometry imaging.

    Science.gov (United States)

    Kiss, András; Smith, Donald F; Jungmann, Julia H; Heeren, Ron M A

    2013-12-30

    Microscope mode imaging for secondary ion mass spectrometry is a technique with the promise of simultaneous high spatial resolution and high-speed imaging of biomolecules from complex surfaces. Technological developments such as new position-sensitive detectors, in combination with polyatomic primary ion sources, are required to exploit the full potential of microscope mode mass spectrometry imaging, i.e. to efficiently push the limits of ultra-high spatial resolution, sample throughput and sensitivity. In this work, a C60 primary source was combined with a commercial mass microscope for microscope mode secondary ion mass spectrometry imaging. The detector setup is a pixelated detector from the Medipix/Timepix family with high-voltage post-acceleration capabilities. The system's mass spectral and imaging performance is tested with various benchmark samples and thin tissue sections. The high secondary ion yield (with respect to 'traditional' monatomic primary ion sources) of the C60 primary ion source and the increased sensitivity of the high voltage detector setup improve microscope mode secondary ion mass spectrometry imaging. The analysis time and the signal-to-noise ratio are improved compared with other microscope mode imaging systems, all at high spatial resolution. We have demonstrated the unique capabilities of a C60 ion microscope with a Timepix detector for high spatial resolution microscope mode secondary ion mass spectrometry imaging. Copyright © 2013 John Wiley & Sons, Ltd.

  13. Noise analysis based validation of the dynamics of in-core flux detectors and ion chambers used in SDS and RRS systems

    International Nuclear Information System (INIS)

    Gloeckler, O.; Cooke, D.; Tulett, M.V.

    1996-01-01

    The paper concentrates on some of the recent applications of reactor noise analysis in Ontario Hydro's CANDU stations, related to the dynamics of in-core flux detectors (ICFDs) and ion chambers. These applications include (1) detecting anomalies in the dynamics of ICFDs and ion chambers, (2) estimating the effective prompt fractions of ICFDs in power rundown tests and in noise measurement, (3) detecting the mechanical vibration of ICFD instrument tubes induced by moderator flow, (4) detecting the mechanical vibration of fuel channels induced by coolant flow, (5) identifying the cause of excessive signal fluctuations in certain flux detectors, (6) validating the dynamic coupling between liquid zone control signals. Some of these applications are performed on a regular basis. The noise analysis program, in the Pickering-B station alone, has saved Ontario Hydro millions of dollars during its first three years. The results of the noise analysis program have been also reviewed by the AECB with favorable results. The AECB have expressed interest in Ontario Hydro further exploiting the use of noise analysis technology (author)

  14. On the Acceleration and Anisotropy of Ions Within Magnetotail Dipolarizing Flux Bundles

    Science.gov (United States)

    Zhou, Xu-Zhi; Runov, Andrei; Angelopoulos, Vassilis; Artemyev, Anton V.; Birn, Joachim

    2018-01-01

    Dipolarizing flux bundles (DFBs), earthward propagating structures with enhanced northward magnetic field Bz, are usually believed to carry a distinctly different plasma population from that in the ambient magnetotail plasma sheet. The ion distribution functions within the DFB, however, have been recently found to be largely controlled by the ion adiabaticity parameter κ in the ambient plasma sheet outside the DFB. According to these observations, the ambient κ values of 2-3 usually correspond to a strong perpendicular anisotropy of suprathermal ions within the DFB, whereas for lower κ values the DFB ions become more isotropic. Here we utilize a simple, test particle model to explore the nature of the anisotropy and its dependence on the ambient κ values. We find that the anisotropy originates from successive ion reflections and reentries to the DFB, during which the ions are consecutively accelerated in the perpendicular direction by the DFB-associated electric field. This consecutive acceleration may be interrupted, however, when magnetic field lines are highly curved in the ambient plasma sheet. In this case, the ion trajectories become stochastic outside the DFB, which makes the reflected ions less likely to return to the DFB for another cycle of acceleration; as a consequence, the perpendicular ion anisotropy does not appear. Given that the DFB ions are a free energy source for instabilities when they are injected toward Earth, our simple model (that reproduces most observational features on the anisotropic DFB ion distributions) may shed new lights on the coupling process between magnetotail and inner magnetosphere.

  15. Development of ALICE microstrip detectors at IRST

    International Nuclear Information System (INIS)

    Boscardin, M.; Bosisio, L.; Dalla Betta, G.-F.; Gregori, P.; Rachevskaia, I.; Zorzi, N.

    2001-01-01

    We report on the development of double-sided, AC-coupled, microstrip detectors oriented to the A Large Ion Collider Experiment (ALICE). The main design and processing issues are presented, together with some selected results from the electrical characterization of detectors and related test structures

  16. Pulsed vapor source for use in ion sources for heavy-ion accelerators

    International Nuclear Information System (INIS)

    Shiloh, J.; Chupp, W.; Faltens, A.; Keefe, D.; Kim, C.; Rosenblum, S.; Tiefenback, M.

    1980-01-01

    A pulsed cesium vapor source for use in ion sources for high-current heavy-ion accelerators is described. The source employs a vacuum spark in Cs and its properties are measured with a hot-filament Cs detector

  17. Hard X-ray polarimetry with position sensitve germanium detectors. Studies of the recombination transitions into highly charged ions

    Energy Technology Data Exchange (ETDEWEB)

    Tashenov, Stanislav

    2005-07-01

    In this work a first study of the photon polarization for the process of radiative recombination has been performed. This was done at the ESR storage ring at GSI for uranium ions colliding with N2 at various collision energies. For this measurement a high purity Ge Pixel Detector with a 4 x 4 segmentation matrix was applied. The investigation was performed at the Gas-jet target of the ESR. The detector was placed at 60 and 90 observation angles. The sensitivity of the Compton scattering effect to the linear polarization of the X-Ray radiation was employed for the polarization measurement. Detailed investigations of the scattering and geometrical effects inside the detector were performed in order to develop a method to interpret the experimental data and extract the degree of the linear polarization in the hard X-Ray regime with a high precision. A special emphasis was given to the geometry of the detector and it's influence on the measured pixel-to-pixel Compton scattering intensities. The developed method enabled to achieve a precision of the order of 10% with the Pixel Detector which is dominated by the statistical uncertainties. The obtained results show a good agreement with the theoretical values derived from the exact relativistic calculations. For the case of the linear polarization of the K-REC photons, the measured data con rm the theoretical prediction that strong depolarization effects occur for high projectile charges in the forward hemisphere. The latter is in disagreement with the nonrelativistic theory which predicts a 100 % polarization regardless of the emission angle. (orig.)

  18. Hard X-ray polarimetry with position sensitve germanium detectors. Studies of the recombination transitions into highly charged ions

    International Nuclear Information System (INIS)

    Tashenov, Stanislav

    2005-01-01

    In this work a first study of the photon polarization for the process of radiative recombination has been performed. This was done at the ESR storage ring at GSI for uranium ions colliding with N2 at various collision energies. For this measurement a high purity Ge Pixel Detector with a 4 x 4 segmentation matrix was applied. The investigation was performed at the Gas-jet target of the ESR. The detector was placed at 60 and 90 observation angles. The sensitivity of the Compton scattering effect to the linear polarization of the X-Ray radiation was employed for the polarization measurement. Detailed investigations of the scattering and geometrical effects inside the detector were performed in order to develop a method to interpret the experimental data and extract the degree of the linear polarization in the hard X-Ray regime with a high precision. A special emphasis was given to the geometry of the detector and it's influence on the measured pixel-to-pixel Compton scattering intensities. The developed method enabled to achieve a precision of the order of 10% with the Pixel Detector which is dominated by the statistical uncertainties. The obtained results show a good agreement with the theoretical values derived from the exact relativistic calculations. For the case of the linear polarization of the K-REC photons, the measured data con rm the theoretical prediction that strong depolarization effects occur for high projectile charges in the forward hemisphere. The latter is in disagreement with the nonrelativistic theory which predicts a 100 % polarization regardless of the emission angle. (orig.)

  19. SU-E-T-778: Use of the 2D MatriXX Detector for Measuring Scanned Ion Beam Parameters

    Energy Technology Data Exchange (ETDEWEB)

    Anvar, M Varasteh; Monaco, V; Sacchi, R; Guarachi, L Fanola; Cirio, R [Istituto Nazionale di Fisica Nucleare (INFN), Division of Turin, TO (Italy); University of Torino, Turin, TO (Italy); Giordanengo, S; Marchetto, F; Vignati, A [Istituto Nazionale di Fisica Nucleare (INFN), Division of Turin, TO (Italy); Donetti, M [Istituto Nazionale di Fisica Nucleare (INFN), Division of Turin, TO (Italy); Centro Nazionale di Adroterapia Oncologica (CNAO), Pavia, PV (Italy); Ciocca, M; Panizza, D [Centro Nazionale di Adroterapia Oncologica (CNAO), Pavia, PV (Italy)

    2015-06-15

    Purpose: The quality assurance (QA) procedure has to check the most relevant beam parameters to ensure the delivery of the correct dose to patients. Film dosimetry, which is commonly used for scanned ion beam QA, does not provide immediate results. The purpose of this work is to answer whether, for scanned ion beam therapy, film dosimetry can be replaced with the 2D MatriXX detector as a real-time tool. Methods: MatriXX, equipped with 32×32 parallel plate ion-chambers, is a commercial device intended for pre-treatment verification of conventional radiation therapy.The MatriXX, placed at the isocenter, and GAFCHROMIC films, positioned on the MatriXX entrance, were exposed to 131.44 MeV proton and 221.45 MeV/u Carbon-ion beams.The OmniPro-I’mRT software, applied for the data taking of MatriXX, gives the possibility of acquiring consecutive snapshots. Using the NI LabVIEW, the data from snapshots were logged as text files for further analysis. Radiochromic films were scanned with EPSON scanner and analyzed using software programs developed in-house for comparative purposes. Results: The field dose uniformity, flatness, beam position and beam width were investigated. The field flatness for the region covering 6×6 cm{sup 2} square field was found to be better than 2%. The relative standard deviations, expected to be constant over 2×2, 4×4 and 6×6 pixels from MatriXX measurement gives a uniformity of 1.5% in good agreement with the film results.The beam center position is determined with a resolution better than 200 µm for Carbon and less than 100 µm for proton beam.The FWHM determination for a beam wider than 10 mm is satisfactory, whilst for smaller beams the determination is uncertain. Conclusion: Precise beam position and fast 2D dose distribution can be determined in real-time using MatriXX detector. The results show that MatriXX is quick and accurate enough to be used in charged-particle therapy QA.

  20. A Facile, Nonreactive Hydrogen Peroxide (H2O2) Detection Method Enabled by Ion Chromatography with UV Detector.

    Science.gov (United States)

    Song, Mingrui; Wang, Junli; Chen, Baiyang; Wang, Lei

    2017-11-07

    Hydrogen peroxide (H 2 O 2 ) is ubiquitous in the natural environment, and it is now widely used for pollutant control in water and wastewater treatment processes. However, current analytical methods for H 2 O 2 inevitably require reactions between H 2 O 2 and other reactants to yield signals and are thus likely subjective to the interferences of coexisting colored, oxidative, and reductive compounds. In order to overcome these barriers, we herein for the first time propose to analyze H 2 O 2 by ion chromatography (IC) using an ultraviolet (UV) detector. The proposal is based on two principles: first, that H 2 O 2 can deprotonate to hydroperoxyl ion (HO 2 - ) when eluent pH is higher than the acid-dissociation coefficient of H 2 O 2 (pK a = 11.6); and second, that after separation from other compounds via IC column, H 2 O 2 can be quantified by a UV detector. Under favorable operating conditions, this method has successfully achieved acceptable recoveries (>91%) of H 2 O 2 dosed to ultrapure and natural waters, a calibration curve with R 2 > 0.99 for a wide range of H 2 O 2 concentrations from 0.1 to 50 mg/L and a method detection limit of 0.027 mg/L. In addition, this approach was shown to be capable of distinguishing H 2 O 2 from anions (e.g., fluoride and chloride) and organics (e.g., glycolate) and monochloramine, suggesting that it is insensitive to many neighboring compounds as long as they do not react quickly with H 2 O 2 . Hence, this study proves the combination of IC and UV detector a facile and reliable method for H 2 O 2 measurement.

  1. Ejection of Coulomb Crystals from a Linear Paul Ion Trap for Ion-Molecule Reaction Studies.

    Science.gov (United States)

    Meyer, K A E; Pollum, L L; Petralia, L S; Tauschinsky, A; Rennick, C J; Softley, T P; Heazlewood, B R

    2015-12-17

    Coulomb crystals are being increasingly employed as a highly localized source of cold ions for the study of ion-molecule chemical reactions. To extend the scope of reactions that can be studied in Coulomb crystals-from simple reactions involving laser-cooled atomic ions, to more complex systems where molecular reactants give rise to multiple product channels-sensitive product detection methodologies are required. The use of a digital ion trap (DIT) and a new damped cosine trap (DCT) are described, which facilitate the ejection of Coulomb-crystallized ions onto an external detector for the recording of time-of-flight (TOF) mass spectra. This enables the examination of reaction dynamics and kinetics between Coulomb-crystallized ions and neutral molecules: ionic products are typically cotrapped, thus ejecting the crystal onto an external detector reveals the masses, identities, and quantities of all ionic species at a selected point in the reaction. Two reaction systems are examined: the reaction of Ca(+) with deuterated isotopologues of water, and the charge exchange between cotrapped Xe(+) with deuterated isotopologues of ammonia. These reactions are examples of two distinct types of experiment, the first involving direct reaction of the laser-cooled ions, and the second involving reaction of sympathetically-cooled heavy ions to form a mixture of light product ions. Extensive simulations are conducted to interpret experimental results and calculate optimal operating parameters, facilitating a comparison between the DIT and DCT approaches. The simulations also demonstrate a correlation between crystal shape and image shape on the detector, suggesting a possible means for determining crystal geometry for nonfluorescing ions.

  2. Development of a diamond detector for temporal profile measurements of intense, short ion bunches within the LIGHT project

    Energy Technology Data Exchange (ETDEWEB)

    Jahn, Diana [Technische Universitaet Darmstadt (Germany); Traeger, Michael; Kis, Mladen [GSI Helmholtzzentrum fuer Schwerionenforschung (Germany); Collaboration: LIGHT-Collaboration

    2016-07-01

    In the context of the Laser Ion Generation, Handling and Transport (LIGHT) research project at GSI, laser-driven ion acceleration and beam shaping are explored, combining a target normal sheath acceleration (TNSA) proton source with conventional accelerator technology. In the LIGHT experimental campaign in 2015, protons were accelerated via the TNSA mechanism, an energy of 7.8 MeV was selected and collimated with a pulsed solenoid and injected into a rf cavity. Through phase focusing, temporally compressed proton bunches were generated to a pulse length of <240 ps (FWHM) with up to 5 x 10{sup 8} particles in a single bunch at a distance of 6 m from the source. An ultrafast diamond detector has been specially developed to measure the temporal profile of these bunches and will be presented.

  3. Failed fuel detector

    International Nuclear Information System (INIS)

    Kogure, Sumio; Seya, Toru; Watanabe, Masaaki.

    1976-01-01

    Purpose: To enhance the reliability of a failed fuel detector which detects radioactivity of nuclear fission products leaked out from fuel elements in cooling water. Constitution: Collected specimen is introduced into a separator and co-existing material considered to be an impediment is separated and removed by ion exchange resins, after which this specimen is introduced into a container housing therein a detector to systematically measure radioactivity. Thereby, it is possible to detect a signal lesser in variation in background, and inspection work also becomes simple. (Kawakami, Y.)

  4. Nuclear radiation detectors

    International Nuclear Information System (INIS)

    Kapoor, S.S.; Ramamurthy, V.S.

    1986-01-01

    The present monograph is intended to treat the commonly used detectors in the field of nuclear physics covering important developments of the recent years. After a general introduction, a brief account of interaction of radiation with matter relevant to the processes in radiation detection is given in Chapter II. In addition to the ionization chamber, proportional counters and Geiger Mueller counters, several gas-filled detectors of advanced design such as those recently developed for heavy ion physics and other types of studies have been covered in Chapter III. Semiconductor detectors are dealt with in Chapter IV. The scintillation detectors which function by sensing the photons emitted by the luminescence process during the interaction of the impinging radiation with the scintillation detector medium are described in Chapter V. The topic of neutron detectors is covered in Chapter VI, as in this case the emphasis is more on the method of neutron detection rather than on detector type. Electronic instrumentation related to signal pulse processing dealt with in Chapter VII. The track etch detectors based on the visualization of the track of the impinging charge particle have also been briefly covered in the last chapter. The scope of this monograph is confined to detectors commonly used in low and medium energy nuclear physics research and applications of nuclear techniques. The monograph is intended for post-graduate students and those beginning to work with the radiation detectors. (author)

  5. Liquid ionizing radiaion detector

    International Nuclear Information System (INIS)

    deGaston, A.N.

    1979-01-01

    A normally nonconducting liquid such as liquid hydrocarbon is encased between a pair of electrodes in an enclosure so that when the liquid is subjected to ionizing radiation, the ion pairs so created measurably increase the conductivity of the fluid. The reduced impedance between the electrodes is detectable with a sensitive ohm-meter and indicates the amount of ionizing radiation. The enclosure, the electrodes and the fluid can be constructed of materials that make the response of the detector suitable for calibrating a large range of radiation energy levels. The detector is especially useful in medical applications where tissue equivalent X ray detectors are desired

  6. Comparison of silicon drift detectors made by Amptek and PNDetectors in application to the PHA system for W7-X

    Directory of Open Access Journals (Sweden)

    Krawczyk Natalia

    2016-12-01

    Full Text Available The paper presents comparison of two silicon drift detectors (SDD, one made by Amptek, USA, and the second one by PNDetector, Germany, which are considered for a soft X-ray diagnostic system for W7-X. The sensitive area of the first one is 7 mm2 × 450 μm and the second one is 10 mm2 × 450 μm. The first detector is cooled by a double-stage Peltier element, while the second detector is cooled by single-stage Peltier element. Each one is equipped with a field-effect transistor (FET. In the detector from Amptek, the FET is mounted separately, while in the detector from PNDetector, the FET is integrated on the chip. The nominal energy resolution given by the producers of the first and the second one is 136 eV@5.9 keV (at -50°C and 132 eV@5.9 keV (at -20°C, respectively. Owing to many advantages, the investigated detectors are good candidates for soft X-ray measurements in magnetic confinement devices. They are suitable for soft X-ray diagnostics, like the pulse height analysis (PHA system for the stellarator Wendelstein 7-X, which has been developed and manufactured at the Institute of Plasma Physics and Laser Microfusion (IPPLM, Warsaw, in collaboration with the Max Planck Institute for Plasma Physics (IPP, Greifswald. The diagnostic is important for the measurements of plasma electron temperature, impurities content, and possible suprathermal tails in the spectra. In order to choose the best type of detector, analysis of technical parameters and laboratory tests were done. Detailed studies show that the most suitable detector for the PHA diagnostics is the PNDetector.

  7. A statistical study of ion energization at 1700 km in the auroral region

    Directory of Open Access Journals (Sweden)

    M. Hamrin

    2002-12-01

    Full Text Available We present a comprehensive overview of several potentially relevant causes for the oxygen energization in the auroral region. Data from the Freja satellite near 1700 km altitude are used for an unconditional statistical investigation. The data are obtained in the Northern Hemisphere during 21 months in the declining phase of the solar cycle. The importance of various wave types for the ion energization is statistically studied. We also investigate the correlation of ion heating with precipitating protons, accelerated auroral electrons, suprathermal electron bursts, the electron density variations, Kp index and solar illumination of the nearest conjugate ionosphere. We find that sufficiently strong broad-band ELF waves, electromagnetic ion cyclotron waves, and waves around the lower hybrid frequency are foremost associated with the ion heating. However, magnetosonic waves, with a sharp, lower frequency cutoff just below the proton gyrofrequency, are not found to contribute to the ion heating. In the absence of the first three wave emissions, transversely energized ions are rare. These wave types are approximately equally efficient in heating the ions, but we find that the main source for the heating is broadband ELF waves, since they are most common in the auroral region. We have also observed that the conditions for ion heating are more favourable for smaller ratios of the spectral densities SE /SB of the broadband ELF waves at the oxygen gyrofrequency.Key words. Ionosphere (auroral ionosphere; wave propogation Magnetospheric physics (electric fields

  8. Fast Monte Carlo for ion beam analysis simulations

    International Nuclear Information System (INIS)

    Schiettekatte, Francois

    2008-01-01

    A Monte Carlo program for the simulation of ion beam analysis data is presented. It combines mainly four features: (i) ion slowdown is computed separately from the main scattering/recoil event, which is directed towards the detector. (ii) A virtual detector, that is, a detector larger than the actual one can be used, followed by trajectory correction. (iii) For each collision during ion slowdown, scattering angle components are extracted form tables. (iv) Tables of scattering angle components, stopping power and energy straggling are indexed using the binary representation of floating point numbers, which allows logarithmic distribution of these tables without the computation of logarithms to access them. Tables are sufficiently fine-grained that interpolation is not necessary. Ion slowdown computation thus avoids trigonometric, inverse and transcendental function calls and, as much as possible, divisions. All these improvements make possible the computation of 10 7 collisions/s on current PCs. Results for transmitted ions of several masses in various substrates are well comparable to those obtained using SRIM-2006 in terms of both angular and energy distributions, as long as a sufficiently large number of collisions is considered for each ion. Examples of simulated spectrum show good agreement with experimental data, although a large detector rather than the virtual detector has to be used to properly simulate background signals that are due to plural collisions. The program, written in standard C, is open-source and distributed under the terms of the GNU General Public License

  9. Medium energy ion scattering (MEIS)

    International Nuclear Information System (INIS)

    Dittmann, K.; Markwitz, A.

    2009-01-01

    This report gives an overview about the technique and experimental study of medium energy ion scattering (MEIS) as a quantitative technique to determine and analyse the composition and geometrical structure of crystalline surfaces and near surface-layers by measuring the energy and yield of the backscattered ions. The use of a lower energy range of 50 to 500 keV accelerated ions impinging onto the target surface and the application of a high-resolution electrostatic energy analyser (ESA) makes medium energy ion scattering spectroscopy into a high depth resolution and surface-sensitive version of RBS with less resulting damage effects. This report details the first steps of research in that field of measurement technology using medium energetic backscattered ions detected by means of a semiconductor radiation detector instead of an ESA. The study of medium energy ion scattering (MEIS) has been performed using the 40 keV industrial ion implanter established at GNS Sciences remodelled with supplementary high voltage insulation for the ion source in order to apply voltages up to 45 kV, extra apertures installed in the beamline and sample chamber in order to set the beam diameter accurately, and a semiconductor radiation detector. For measurement purposes a beam of positive charged helium ions accelerated to an energy of about 80 keV has been used impinging onto target surfaces of lead implanted into silicon (PbSi), scandium implanted into aluminium (ScAl), aluminium foil (Al) and glassy carbon (C). First results show that it is possible to use the upgraded industrial implanter for medium energy ion scattering. The beam of 4 He 2+ with an energy up to 88 keV has been focussed to 1 mm in diameter. The 5 nA ion beam hit the samples under 2 x 10 -8 mbar. The results using the surface barrier detector show scattering events from the samples. Cooling of the detector to liquid nitrogen temperatures reduced the electronic noise in the backscattering spectrum close to zero. A

  10. Source Regions of the Interplanetary Magnetic Field and Variability in Heavy-Ion Elemental Composition in Gradual Solar Energetic Particle Events

    Science.gov (United States)

    Ko, Yuan-Kuen; Tylka, Allan J.; Ng, Chee K.; Wang, Yi-Ming; Dietrich, William F.

    2013-01-01

    Gradual solar energetic particle (SEP) events are those in which ions are accelerated to their observed energies by interactions with a shock driven by a fast coronal mass-ejection (CME). Previous studies have shown that much of the observed event-to-event variability can be understood in terms of shock speed and evolution in the shock-normal angle. But an equally important factor, particularly for the elemental composition, is the origin of the suprathermal seed particles upon which the shock acts. To tackle this issue, we (1) use observed solar-wind speed, magnetograms, and the PFSS model to map the Sun-L1 interplanetary magnetic field (IMF) line back to its source region on the Sun at the time of the SEP observations; and (2) then look for correlation between SEP composition (as measured by Wind and ACE at approx. 2-30 MeV/nucleon) and characteristics of the identified IMF-source regions. The study is based on 24 SEP events, identified as a statistically-significant increase in approx. 20 MeV protons and occurring in 1998 and 2003-2006, when the rate of newly-emergent solar magnetic flux and CMEs was lower than in solar-maximum years and the field-line tracing is therefore more likely to be successful. We find that the gradual SEP Fe/O is correlated with the field strength at the IMF-source, with the largest enhancements occurring when the footpoint field is strong, due to the nearby presence of an active region. In these cases, other elemental ratios show a strong charge-to-mass (q/M) ordering, at least on average, similar to that found in impulsive events. These results lead us to suggest that magnetic reconnection in footpoint regions near active regions bias the heavy-ion composition of suprathermal seed ions by processes qualitatively similar to those that produce larger heavy-ion enhancements in impulsive SEP events. To address potential technical concerns about our analysis, we also discuss efforts to exclude impulsive SEP events from our event sample.

  11. Floating-point-based hardware accelerator of a beam phase-magnitude detector and filter for a beam phase control system in a heavy-ion synchrotron application

    International Nuclear Information System (INIS)

    Samman, F.A.; Pongyupinpanich Surapong; Spies, C.; Glesner, M.

    2012-01-01

    A hardware implementation of an adaptive phase and magnitude detector and filter of a beam-phase control system in a heavy ion synchrotron application is presented in this paper. The main components of the hardware are adaptive LMS (Least-Mean-Square) filters and phase and magnitude detectors. The phase detectors are implemented by using a CORDIC (Coordinate Rotation Digital Computer) algorithm based on 32-bit binary floating-point arithmetic data formats. The floating-point-based hardware is designed to improve the precision of the past hardware implementation that were based on fixed-point arithmetics. The hardware of the detector and the adaptive LMS filter have been implemented on a programmable logic device (FPGA) for hardware acceleration purpose. The ideal Matlab/Simulink model of the hardware and the VHDL model of the adaptive LMS filter and the phase and magnitude detector are compared. The comparison result shows that the output signal of the floating-point based adaptive FIR filter as well as the phase and magnitude detector agree with the expected output signal of the ideal Matlab/Simulink model. (authors)

  12. Knock-on electrons in WA98 silicon drift detector

    International Nuclear Information System (INIS)

    Eliseev, S.

    1997-01-01

    Silicon Drift Detector is used to estimate production of knock-on electrons created by passage of 158 GeV /u fully stripped Pb ion through thick lead target. Analysed data were collected in 1995 during Pb+Pb run in WA98 heavy ion experiment at CERN SPS. Information from WA98 Cherenkov beam counter makes it possible to classify events according to number of additional Pb ions which have during detector's read-out time passed through the target without nuclear interaction. Events with one and none pile-up ion are used for statistical separation of knock-on electrons from all detected charged particles. Resulting inclusive spectra of knock-on electrons are compared with GRANT simulations and good agreement is found. (author)

  13. Ion trap simulations of quantum fields in an expanding universe.

    Science.gov (United States)

    Alsing, Paul M; Dowling, Jonathan P; Milburn, G J

    2005-06-10

    We propose an experiment in which the phonon excitation of ion(s) in a trap, with a trap frequency exponentially modulated at rate kappa, exhibits a thermal spectrum with an "Unruh" temperature given by k(B)T=Planck kappa. We discuss the similarities of this experiment to the response of detectors in a de Sitter universe and the usual Unruh effect for uniformly accelerated detectors. We demonstrate a new Unruh effect for detectors that respond to antinormally ordered moments using the ion's first blue sideband transition.

  14. The in-beam tracking detectors for R3B

    Energy Technology Data Exchange (ETDEWEB)

    Paschalis, Stefanos; Johansen, Jacob; Scheit, Heiko [Institut fuer Kernphysik, Technische Universitaet, D 64289 Darmstadt (Germany); Heil, Michael [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, D-64291 Darmstadt (Germany); Aumann, Thomas [Institut fuer Kernphysik, Technische Universitaet, D 64289 Darmstadt (Germany); GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, D-64291 Darmstadt (Germany); Krivshich, Anatoly [PNPI St. Petersburg, 188300 Gatchina (Russian Federation); Collaboration: R3B-Collaboration

    2015-07-01

    The R3B experiment is part of the NUSTAR pillar at FAIR. One of the great strengths of the R3B experiment is the kinematically complete measurement of reactions with exotic ions with energies of up to 1 AGeV. Key components of the R3B experiment are the neutron detector NeuLAND, the γ and charge-particle calorimeter CALIFA, the Si Tracker and the in-beam tracking detectors. A cornerstone instrument of the setup is the new dipole magnet (GLAD) which bends and momentum analyses the high-rigidity beams. A precise tracking of the charged particles through the magnetic field is crucial to resolve the masses of heavy ions and measure the momentum of the fragments with high resolution. In this contribution we present the technical design details of the in-beam tracking detectors that will be used in the R3B experiment together with recent results obtained from in-beam prototype testing. In particular, we discuss Si detectors, detectors based on plastic-scintillator fibers and paddles, straw-tube gas detectors and the overall performance of the system.

  15. Measurements of ion mobility in argon and neon based gas mixtures

    CERN Document Server

    INSPIRE-00507268

    2017-01-01

    As gaseous detectors are operated at high rates of primary ionisation, ions created in the detector have a considerable impact on the performance of the detector. The upgraded ALICE Time Projection Chamber (TPC) will operate during LHC Run$\\,3$ with a substantial space charge density of positive ions in the drift volume. In order to properly simulate such space charges, knowledge of the ion mobility $K$ is necessary. To this end, a small gaseous detector was constructed and the ion mobility of various gas mixtures was measured. To validate the corresponding signal analysis, simulations were performed. Results are shown for several argon and neon based mixtures with different $\\textrm{CO}_2$ fractions. A decrease of $K$ was measured for increasing water content.

  16. On acceleration of <1 MeV/n He ions in the corotating compression regions near 1 AU: STEREO observations

    Directory of Open Access Journals (Sweden)

    R. Bučík

    2009-09-01

    Full Text Available Observations of multi-MeV corotating interaction region (CIR ions are in general consistent with models of CIR shock acceleration and transport. The presence of suprathermal particles near 1 AU in unshocked compression regions is not adequately explained. Nonetheless, more recent works demonstrate that unshocked compression regions associated with CIRs near 1 AU could energize particles. In the energy range from ~0.1 to ~1 MeV/n we investigate CIR events observed in 2007–2008 by the STEREO A and B spacecraft. We treat the predictions of compression acceleration by comparing the observed ion intensities with the model parameters. These observations show that the ion intensity in CIR events with in-situ reverse shock is well organized by the parameters which characterize the compression region itself, like compression width, solar wind speed gradients and the total pressure. In turn, for CIR events with the absence of the shocks the model predictions are not fulfilled.

  17. Control of secondary electrons from ion beam impact using a positive potential electrode

    Energy Technology Data Exchange (ETDEWEB)

    Crowley, T. P., E-mail: tpcrowley@xanthotechnologies.com; Demers, D. R.; Fimognari, P. J. [Xantho Technologies, LLC, Madison, Wisconsin 53705 (United States)

    2016-11-15

    Secondary electrons emitted when an ion beam impacts a detector can amplify the ion beam signal, but also introduce errors if electrons from one detector propagate to another. A potassium ion beam and a detector comprised of ten impact wires, four split-plates, and a pair of biased electrodes were used to demonstrate that a low-voltage, positive electrode can be used to maintain the beneficial amplification effect while greatly reducing the error introduced from the electrons traveling between detector elements.

  18. A timing detector with pulsed high-voltage power supply for mass measurements at CSRe

    International Nuclear Information System (INIS)

    Zhang, W.; Tu, X.L.; Wang, M.; Zhang, Y.H.; Xu, H.S.; Litvinov, Yu. A.; Blaum, K.

    2014-01-01

    Accuracy of nuclear mass measurements in storage rings depends critically on the accuracy with which the revolution times of stored ions can be obtained. In such experiments, micro-channel plates (MCP) are used as timing detectors. Due to large phase space of injected secondary beams, a large number of ions cannot be stored in the ring and is lost within the first few revolutions. However, these ions interact with the detector and can saturate the MCP and thus deteriorate its performance. In order to eliminate such effects, a fast, pulsed high-voltage power supply (PHVPS) has been employed which keeps the detector switched-off during the first few revolutions. The new detector setup was taken into operation at the Experimental Cooler-Storage-Ring CSRe in Lanzhou and resulted in a significant improvement of the detector amplitude and efficiency characteristics

  19. The Phenix Detector magnet subsystem

    International Nuclear Information System (INIS)

    Yamamoto, R.M.; Bowers, J.M.; Harvey, A.R.

    1995-01-01

    The PHENIX [Photon Electron New Heavy Ion Experiment] Detector is one of two large detectors presently under construction for RHIC (Relativistic Heavy Ion Collider) located at Brookhaven National Laboratory. Its primary goal is to detect a new phase of matter; the quark-gluon plasma. In order to achieve this objective, the PHENIX Detector utilizes a complex magnet subsystem which is comprised of two large magnets identified as the Central Magnet (CM) and the Muon Magnet (MM). Muon Identifier steel is also included as part of this package. The entire magnet subsystem stands over 10 meters tall and weighs in excess of 1900 tons (see Fig. 1). Magnet size alone provided many technical challenges throughout the design and fabrication of the project. In addition, interaction with foreign collaborators provided the authors with new areas to address and problems to solve. Russian collaborators would fabricate a large fraction of the steel required and Japanese collaborators would supply the first coil. This paper will describe the overall design of the PHENIX magnet subsystem and discuss its present fabrication status

  20. The Phenix Detector magnet subsystem

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, R.M.; Bowers, J.M.; Harvey, A.R. [Lawrence Livermore National Lab., CA (United States)] [and others

    1995-05-19

    The PHENIX [Photon Electron New Heavy Ion Experiment] Detector is one of two large detectors presently under construction for RHIC (Relativistic Heavy Ion Collider) located at Brookhaven National Laboratory. Its primary goal is to detect a new phase of matter; the quark-gluon plasma. In order to achieve this objective, the PHENIX Detector utilizes a complex magnet subsystem which is comprised of two large magnets identified as the Central Magnet (CM) and the Muon Magnet (MM). Muon Identifier steel is also included as part of this package. The entire magnet subsystem stands over 10 meters tall and weighs in excess of 1900 tons (see Fig. 1). Magnet size alone provided many technical challenges throughout the design and fabrication of the project. In addition, interaction with foreign collaborators provided the authors with new areas to address and problems to solve. Russian collaborators would fabricate a large fraction of the steel required and Japanese collaborators would supply the first coil. This paper will describe the overall design of the PHENIX magnet subsystem and discuss its present fabrication status.

  1. Performance of upstream interaction region detectors for the FIRST experiment at GSI

    CERN Document Server

    Abou-Haidar, Z; Alvarez, M A G; Anelli, M; Aumann, T; Battistoni, G; Bocci, A; Bohlen, T T; Boudard, A; Brunetti, A; Carpinelli, M; Cirrone, G A P; Cortes-Giraldo, M A; Cuttone, G; De Napoli, M; Durante, M; Fernandez-Garcia, J P; Finck, C; Gallardo, M I; Golosio, B; Iarocci, E; Iazzi, F; Ickert, G; Introzzi, R; Juliani, D; Krimmer, J; Kurz, N; Labalme, M; Leifels, Y; Le Fevre, A; Leray, S; Marchetto, F; Monaco, V; Morone, M C; Oliva, P; Paoloni, A; Patera, V; Piersanti, L; Pleskac, R; Quesada, J M; Randazzo, N; Romano, F; Rossi, D; Rosso, V; Rousseau, M; Sacchi, R; Sala, P; Sarti, A; Schuy, C; Sciubba, A; Sfienti, C; Simon, H; Sipala, V; Spiriti, E; Stuttge, L; Tropea, S; Younis, H

    2012-01-01

    The FIRST (Fragmentation of Ions Relevant for Space and Therapy) experiment at GSI has been designed to study carbon fragmentation, measuring (12)C double differential cross sections (- (2)I /- - E) for different beam energies between 100 and 1000 MeV/u. The experimental setup integrates newly designed detectors in the, so called, Interaction Region around the graphite target. The Interaction Region upstream detectors are a 250 mum thick scintillator and a drift chamber optimized for a precise measurement of the ions interaction time and position on the target. In this article we review the design of the upstream detectors along with the preliminary results of the data taking performed on August 2011 with 400 MeV/u fully stripped carbon ion beam at GSI. Detectors performances will be reviewed and compared to those obtained during preliminary tests, performed with 500 MeV electrons (at the BTF facility in the INFN Frascati Laboratories) and 80 MeV/u protons and carbon ions (at the INFN LNS Laboratories in Cata...

  2. BROOKHAVEN: Major detectors for RHIC under construction

    International Nuclear Information System (INIS)

    Ludlam, Thomas W.

    1994-01-01

    On March 9-10, a cost and schedule review at Brookhaven verified construction readiness for the PHENIX detector (May 1993, page 10). PHENIX thus joins STAR (Solenoidal Tracking at RHIC - November 1991, page 17), whose construction plan was ratified in January 1993, as a major detector to take data when the RHIC heavy ion collider is completed in mid-1999. The goal of both detectors is to search for the transition from ordinary nuclear matter to a new state of matter consisting of (momentarily) unconfined quarks and gluons. This transition to a ''quark-gluon plasma'' (QGP) is predicted to occur under extreme conditions of temperature and energy density, as is likely to be the case in the collision of heavy ions of sufficient energy. RHIC is expected to produce the highest energy densities ever observed on the nuclear scale

  3. Compound Semiconductor Radiation Detector

    International Nuclear Information System (INIS)

    Kim, Y. K.; Park, S. H.; Lee, W. G.; Ha, J. H.

    2005-01-01

    In 1945, Van Heerden measured α, β and γ radiations with the cooled AgCl crystal. It was the first radiation measurement using the compound semiconductor detector. Since then the compound semiconductor has been extensively studied as radiation detector. Generally the radiation detector can be divided into the gas detector, the scintillator and the semiconductor detector. The semiconductor detector has good points comparing to other radiation detectors. Since the density of the semiconductor detector is higher than that of the gas detector, the semiconductor detector can be made with the compact size to measure the high energy radiation. In the scintillator, the radiation is measured with the two-step process. That is, the radiation is converted into the photons, which are changed into electrons by a photo-detector, inside the scintillator. However in the semiconductor radiation detector, the radiation is measured only with the one-step process. The electron-hole pairs are generated from the radiation interaction inside the semiconductor detector, and these electrons and charged ions are directly collected to get the signal. The energy resolution of the semiconductor detector is generally better than that of the scintillator. At present, the commonly used semiconductors as the radiation detector are Si and Ge. However, these semiconductor detectors have weak points. That is, one needs thick material to measure the high energy radiation because of the relatively low atomic number of the composite material. In Ge case, the dark current of the detector is large at room temperature because of the small band-gap energy. Recently the compound semiconductor detectors have been extensively studied to overcome these problems. In this paper, we will briefly summarize the recent research topics about the compound semiconductor detector. We will introduce the research activities of our group, too

  4. High rate multiplicity detector for relativistic heavy-ion collisions

    International Nuclear Information System (INIS)

    Beavis, D.; Bennett, M.J.; Carroll, J.B.; Chiba, J.; Chikanian, A.; Crawford, H.J.; Cronqvist, M.; Dardenne, Y.; Debbe, R.; Doke, T.; Engelage, J.; Flores, I.; Greiner, L.; Hayano, R.S.; Hallman, T.J.; Heckman, H.H.; Kashiwagi, T.; Kikuchi, J.; Kumar, B.S.; Kuo, C.; Lindstrom, P.J.; Mitchell, J.W.; Nagamiya, S.; Nagle, J.L.; Pope, J.K.; Stankus, P.; Tanaka, K.H.; Welsh, R.C.; Zhan, W.

    1995-01-01

    We have constructed and operated a detector to measure the multiplicity of secondary particles produced in nucleus-nucleus collisions in the E878 experiment at the Brookhaven National Laboratory AGS facility. We describe the operation and performance of the detector in a high rate Au beam environment, and interpret the multiplicity data in terms of the impact parameters of the nucleus-nucleus collisions. ((orig.))

  5. High rate multiplicity detector for relativistic heavy-ion collisions

    Energy Technology Data Exchange (ETDEWEB)

    Beavis, D [Brookhaven National Lab., Upton, NY (United States); Bennett, M J [Yale University, A.W. Wright Nuclear Structure Laboratory, New Haven, CT 06511 (United States); Carroll, J B [University of California at Los Angeles, Los Angeles, CA (United States); Chiba, J [KEK National High Energy Physics, Tsukuba (Japan); Chikanian, A [Yale University, A.W. Wright Nuclear Structure Laboratory, New Haven, CT 06511 (United States); Crawford, H J [University of California Space Sciences Laboratory, Berkeley, CA (United States); Cronqvist, M [University of California Space Sciences Laboratory, Berkeley, CA (United States); Dardenne, Y [University of California Space Sciences Laboratory, Berkeley, CA (United States); Debbe, R [Brookhaven National Lab., Upton, NY (United States); Doke, T [Waseda University, Science and Engineering Research Institute, Waseda (Japan); Engelage, J [University of California Space Sciences Laboratory, Berkeley, CA (United States); Flores, I [University of California Space Sciences Laboratory, Berkeley, CA (United States); Greiner, L [University of California Space Sciences Laboratory, Berkeley, CA (United States); Hayano, R S [University of Tokyo, Tokyo (Japan); Hallman, T J [University of California at Los Angeles, Los Angeles, CA (United States); Heckman, H H [Lawrence Berkeley Lab., CA (United States); Kashiwagi, T [Waseda University, Science and Engineering Research Institute, Waseda (Japan); Kikuchi, J [Waseda University, Science and Engineering Research Institute, Waseda (Japan); Kumar, B S [Yale University, A.W. Wright Nuclear Structure Laboratory, New Haven, CT 06511 (United States); Kuo, C [University of California Space Sciences Laboratory, Berkeley, CA (United States); Lindstrom, P J [Lawrence Berkeley Lab., CA (United States); Mitchell, J W [Universities Space Research Association/Goddard Space Flight Center, Greenbelt, MD (United States); Nagamiya, S; E878 Collaboration

    1995-04-21

    We have constructed and operated a detector to measure the multiplicity of secondary particles produced in nucleus-nucleus collisions in the E878 experiment at the Brookhaven National Laboratory AGS facility. We describe the operation and performance of the detector in a high rate Au beam environment, and interpret the multiplicity data in terms of the impact parameters of the nucleus-nucleus collisions. ((orig.)).

  6. Multi-sensor radiation detector system

    International Nuclear Information System (INIS)

    Foster, R.G.; Cyboron, R.D.

    1975-01-01

    The invention is a multi-sensor radiation detection system including a self-powered detector and an ion or fission chamber, preferably joined as a unitary structure, for removable insertion into a nuclear reactor. The detector and chamber are connected electrically in parallel, requiring but two conductors extending out of the reactor to external electrical circuitry which includes a load impedance, a voltage source, and switch means. The switch means are employed to alternately connect the detector and chamber either with th load impedance or with the load impedance and the voltage source. In the former orientation, current through the load impedance indicates flux intensity at the self-powered detector and in the latter orientation, the current indicates flux intensity at the detector and fission chamber, though almost all of the current is contributed by the fission chamber. (auth)

  7. Low material budget floating strip Micromegas for ion transmission radiography

    Energy Technology Data Exchange (ETDEWEB)

    Bortfeldt, J., E-mail: jonathan.bortfeldt@cern.ch [LMU Munich, LS Schaile, Am Coulombwall 1, D-85748 Garching (Germany); Biebel, O.; Flierl, B.; Hertenberger, R.; Klitzner, F.; Lösel, Ph. [LMU Munich, LS Schaile, Am Coulombwall 1, D-85748 Garching (Germany); Magallanes, L. [LMU Munich, LS Parodi, Am Coulombwall 1, D-85748 Garching (Germany); University Hospital Heidelberg, Im Neuenheimer Feld 672, D-69120 Heidelberg (Germany); Müller, R. [LMU Munich, LS Schaile, Am Coulombwall 1, D-85748 Garching (Germany); Parodi, K. [LMU Munich, LS Parodi, Am Coulombwall 1, D-85748 Garching (Germany); Heidelberg Ion-Beam Therapy Center, Im Neuenheimer Feld 450, D-69120 Heidelberg (Germany); Schlüter, T. [LMU Munich, Excellence Cluster Universe, Boltzmannstr. 2, D-85748 Garching (Germany); Voss, B. [GSI Helmholtzzentrum für Schwerionenforschung GmbH, Planckstr. 1, D-64291 Darmstadt (Germany); Zibell, A. [JMU Würzburg, Sanderring 2, D-97070 Würzburg (Germany)

    2017-02-11

    Floating strip Micromegas are high-accuracy and discharge insensitive gaseous detectors, able to track single particles at fluxes of 7 MHz/cm{sup 2} with 100 μm resolution. We developed low-material-budget detectors with one-dimensional strip readout, suitable for tracking at highest particle rates as encountered in medical ion transmission radiography or inner tracker applications. Recently we additionally developed Kapton-based floating strip Micromegas with two-dimensional strip readout, featuring an overall thickness of 0.011 X{sub 0}. These detectors were tested in high-rate proton and carbon-ion beams at the tandem accelerator in Garching and the Heidelberg Ion-Beam Therapy Center, operated with an optimized Ne:CF{sub 4} gas mixture. By coupling the Micromegas detectors to a new scintillator based range detector, ion transmission radiographies of PMMA and tissue-equivalent phantoms were acquired. The range detector with 18 layers is read out via wavelength shifting fibers, coupled to a multi-anode photomultiplier. We present the performance of the Micromegas detectors with respect to timing and single plane track reconstruction using the μTPC method. We discuss the range resolution of the scintillator range telescope and present the image reconstruction capabilities of the combined system.

  8. P-type silicon drift detectors

    International Nuclear Information System (INIS)

    Walton, J.T.; Krieger, B.; Krofcheck, D.; O'Donnell, R.; Odyniec, G.; Partlan, M.D.; Wang, N.W.

    1995-06-01

    Preliminary results on 16 CM 2 , position-sensitive silicon drift detectors, fabricated for the first time on p-type silicon substrates, are presented. The detectors were designed, fabricated, and tested recently at LBL and show interesting properties which make them attractive for use in future physics experiments. A pulse count rate of approximately 8 x l0 6 s -1 is demonstrated by the p-type silicon drift detectors. This count rate estimate is derived by measuring simultaneous tracks produced by a laser and photolithographic mask collimator that generates double tracks separated by 50 μm to 1200 μm. A new method of using ion-implanted polysilicon to produce precise valued bias resistors on the silicon drift detectors is also discussed

  9. On plasma coupling and turbulence effects in low velocity stopping

    Energy Technology Data Exchange (ETDEWEB)

    Kurilenkov, Yu K [Unified Institute for High Temperatures of Russian Academy of Sciences, 13/19 Izhorskaya Str., 125412 Moscow (Russian Federation); Maynard, G [Laboratoire de Physique des Gaz et des Plasmas, UMR-8578, Bat. 210, Universite Paris XI, F-91405 Orsay (France); Barriga-Carrasco, M D [Laboratoire de Physique des Gaz et des Plasmas, UMR-8578, Bat. 210, Universite Paris XI, F-91405 Orsay (France); Valuev, A A [Unified Institute for High Temperatures of Russian Academy of Sciences, 13/19 Izhorskaya Str., 125412 Moscow (Russian Federation)

    2006-04-28

    The problem of stopping power (SP) for projectile ions is analysed in terms of the dielectric function and effective collision frequency for moderately dense and strongly coupled plasmas (SCP). We consider several issues regarding the calculation of stopping power for correlated ensembles of particles and oscillators. In particular, effects of group (few particle) modes, transition from positive to negative dispersion and excitation of collective modes up to suprathermal level at plasma targets are addressed. Linear SP of dense suprathermal (nonlinear) plasma targets at different levels of target plasma turbulence is estimated. The force of suprathermal plasma oscillations on the projectile ions is mostly in the nature of increased frictional drag. The results obtained show the possibility of increasing low velocity stopping (up to 'turbulent' values) in comparison with losses in equilibrium dense plasma targets. Experimental conditions to create specific turbulent targets as well as some connection between stopping phenomena and SCP transport properties are discussed briefly.

  10. On plasma coupling and turbulence effects in low velocity stopping

    International Nuclear Information System (INIS)

    Kurilenkov, Yu K; Maynard, G; Barriga-Carrasco, M D; Valuev, A A

    2006-01-01

    The problem of stopping power (SP) for projectile ions is analysed in terms of the dielectric function and effective collision frequency for moderately dense and strongly coupled plasmas (SCP). We consider several issues regarding the calculation of stopping power for correlated ensembles of particles and oscillators. In particular, effects of group (few particle) modes, transition from positive to negative dispersion and excitation of collective modes up to suprathermal level at plasma targets are addressed. Linear SP of dense suprathermal (nonlinear) plasma targets at different levels of target plasma turbulence is estimated. The force of suprathermal plasma oscillations on the projectile ions is mostly in the nature of increased frictional drag. The results obtained show the possibility of increasing low velocity stopping (up to 'turbulent' values) in comparison with losses in equilibrium dense plasma targets. Experimental conditions to create specific turbulent targets as well as some connection between stopping phenomena and SCP transport properties are discussed briefly

  11. MTF measurement and analysis of linear array HgCdTe infrared detectors

    Science.gov (United States)

    Zhang, Tong; Lin, Chun; Chen, Honglei; Sun, Changhong; Lin, Jiamu; Wang, Xi

    2018-01-01

    The slanted-edge technique is the main method for measurement detectors MTF, however this method is commonly used on planar array detectors. In this paper the authors present a modified slanted-edge method to measure the MTF of linear array HgCdTe detectors. Crosstalk is one of the major factors that degrade the MTF value of such an infrared detector. This paper presents an ion implantation guard-ring structure which was designed to effectively absorb photo-carriers that may laterally defuse between adjacent pixels thereby suppressing crosstalk. Measurement and analysis of the MTF of the linear array detectors with and without a guard-ring were carried out. The experimental results indicated that the ion implantation guard-ring structure effectively suppresses crosstalk and increases MTF value.

  12. MAVEN Observations of Escaping Planetary Ions from the Martian Atmosphere: Mass, Velocity, and Spatial Distributions

    Science.gov (United States)

    Dong, Yaxue; Fang, Xiaohua; Brain, D. A.; McFadden, James P.; Halekas, Jasper; Connerney, Jack

    2015-04-01

    The Mars-solar wind interaction accelerates and transports planetary ions away from the Martian atmosphere through a number of processes, including ‘pick-up’ by electromagnetic fields. The MAVEN spacecraft has made routine observations of escaping planetary ions since its arrival at Mars in September 2014. The SupraThermal And Thermal Ion Composition (STATIC) instrument measures the ion energy, mass, and angular spectra. It has detected energetic planetary ions during most of the spacecraft orbits, which are attributed to the pick-up process. We found significant variations in the escaping ion mass and velocity distributions from the STATIC data, which can be explained by factors such as varying solar wind conditions, contributions of particles from different source locations and different phases during the pick-up process. We also study the spatial distributions of different planetary ion species, which can provide insight into the physics of ion escaping process and enhance our understanding of atmospheric erosion by the solar wind. Our results will be further interpreted within the context of the upstream solar wind conditions measured by the MAVEN Solar Wind Ion Analyzer (SWIA) instrument and the magnetic field environment measured by the Magnetometer (MAG) instrument. Our study shows that the ion spatial distribution in the Mars-Sun-Electric-Field (MSE) coordinate system and the velocity space distribution with respect to the local magnetic field line can be used to distinguish the ions escaping through the polar plume and those through the tail region. The contribution of the polar plume ion escape to the total escape rate will also be discussed.

  13. Laser-cooled atomic ions as probes of molecular ions

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Kenneth R.; Viteri, C. Ricardo; Clark, Craig R.; Goeders, James E.; Khanyile, Ncamiso B.; Vittorini, Grahame D. [Schools of Chemistry and Biochemistry, Computational Science and Engineering and Physics, Georgia Institute of Technology, Atlanta, GA 30332 (United States)

    2015-01-22

    Trapped laser-cooled atomic ions are a new tool for understanding cold molecular ions. The atomic ions not only sympathetically cool the molecular ions to millikelvin temperatures, but the bright atomic ion fluorescence can also serve as a detector of both molecular reactions and molecular spectra. We are working towards the detection of single molecular ion spectra by sympathetic heating spectroscopy. Sympathetic heating spectroscopy uses the coupled motion of two trapped ions to measure the spectra of one ion by observing changes in the fluorescence of the other ion. Sympathetic heating spectroscopy is a generalization of quantum logic spectroscopy, but does not require ions in the motional ground state or coherent control of the ion internal states. We have recently demonstrated this technique using two isotopes of Ca{sup +} [Phys. Rev. A, 81, 043428 (2010)]. Limits of the method and potential applications for molecular spectroscopy are discussed.

  14. Effects induced by high and low intensity laser plasma on SiC Schottky detectors

    Directory of Open Access Journals (Sweden)

    Sciuto Antonella

    2018-01-01

    Full Text Available Silicon-Carbide detectors are extensively employed as diagnostic devices in laser-generated plasma, allowing the simultaneous detection of photons, electrons and ions, when used in time-of-flight configuration. The plasma generated by high intensity laser (1016 W/cm2 producing high energy ions was characterized by SiC detector with a continuous front-electrode, and a very thick active depth, while SiC detector with an Interdigit front-electrode was used to measure the low energy ions of plasma generated by low intensity laser (1010 W/cm2. Information about ion energy, number of charge states, plasma temperature can be accurately obtained. However, laser exposure induces the formation of surface and bulk defects whose concentration increases with increasing the time to plasma exposure. The surface defects consist of clusters with a main size of the order of some microns and they modify the diode barrier height and the efficiency of the detector as checked by alpha spectrometry. The bulk defects, due to the energy loss of detected ions, strongly affect the electrical properties of the device, inducing a relevant increase of the leakage (reverse current and decrease the forward current related to a deactivation of the dopant in the active detector region.

  15. Effects induced by high and low intensity laser plasma on SiC Schottky detectors

    Science.gov (United States)

    Sciuto, Antonella; Torrisi, Lorenzo; Cannavò, Antonino; Mazzillo, Massimo; Calcagno, Lucia

    2018-01-01

    Silicon-Carbide detectors are extensively employed as diagnostic devices in laser-generated plasma, allowing the simultaneous detection of photons, electrons and ions, when used in time-of-flight configuration. The plasma generated by high intensity laser (1016 W/cm2) producing high energy ions was characterized by SiC detector with a continuous front-electrode, and a very thick active depth, while SiC detector with an Interdigit front-electrode was used to measure the low energy ions of plasma generated by low intensity laser (1010 W/cm2). Information about ion energy, number of charge states, plasma temperature can be accurately obtained. However, laser exposure induces the formation of surface and bulk defects whose concentration increases with increasing the time to plasma exposure. The surface defects consist of clusters with a main size of the order of some microns and they modify the diode barrier height and the efficiency of the detector as checked by alpha spectrometry. The bulk defects, due to the energy loss of detected ions, strongly affect the electrical properties of the device, inducing a relevant increase of the leakage (reverse) current and decrease the forward current related to a deactivation of the dopant in the active detector region.

  16. Development of floating strip micromegas detectors

    Energy Technology Data Exchange (ETDEWEB)

    Bortfeldt, Jonathan

    2014-04-28

    Micromegas are high-rate capable, high-resolution micro-pattern gaseous detectors. Square meter sized resistive strip Micromegas are foreseen as replacement of the currently used precision tracking detectors in the Small Wheel, which is part of the forward region of the ATLAS muon spectrometer. The replacement is necessary to ensure tracking and triggering performance of the muon spectrometer after the luminosity increase of the Large Hadron Collider beyond its design value of 10{sup 34} cm{sup -2}s{sup -1} around 2020. In this thesis a novel discharge tolerant floating strip Micromegas detector is presented and described. By individually powering copper anode strips, the effects of a discharge are confined to a small region of the detector. This reduces the impact of discharges on the efficiency by three orders of magnitude, compared to a standard Micromegas. The physics of the detector is studied and discussed in detail. Several detectors are developed: A 6.4 x 6.4 cm{sup 2} floating strip Micromegas with exchangeable SMD capacitors and resistors allows for an optimization of the floating strip principle. The discharge behavior is investigated on this device in depth. The microscopic structure of discharges is quantitatively explained by a detailed detector simulation. A 48 x 50 cm{sup 2} floating strip Micromegas is studied in high energy pion beams. Its homogeneity with respect to pulse height, efficiency and spatial resolution is investigated. The good performance in high-rate background environments is demonstrated in cosmic muon tracking measurements with a 6.4 x 6.4 cm{sup 2} floating strip Micromegas under lateral irradiation with 550 kHz 20 MeV proton beams. A floating strip Micromegas doublet with low material budget is developed for ion tracking without limitations from multiple scattering in imaging applications during medical ion therapy. Highly efficient tracking of 20 MeV protons at particle rates of 550 kHz is possible. The reconstruction of the

  17. Development of floating strip micromegas detectors

    International Nuclear Information System (INIS)

    Bortfeldt, Jonathan

    2014-01-01

    Micromegas are high-rate capable, high-resolution micro-pattern gaseous detectors. Square meter sized resistive strip Micromegas are foreseen as replacement of the currently used precision tracking detectors in the Small Wheel, which is part of the forward region of the ATLAS muon spectrometer. The replacement is necessary to ensure tracking and triggering performance of the muon spectrometer after the luminosity increase of the Large Hadron Collider beyond its design value of 10 34 cm -2 s -1 around 2020. In this thesis a novel discharge tolerant floating strip Micromegas detector is presented and described. By individually powering copper anode strips, the effects of a discharge are confined to a small region of the detector. This reduces the impact of discharges on the efficiency by three orders of magnitude, compared to a standard Micromegas. The physics of the detector is studied and discussed in detail. Several detectors are developed: A 6.4 x 6.4 cm 2 floating strip Micromegas with exchangeable SMD capacitors and resistors allows for an optimization of the floating strip principle. The discharge behavior is investigated on this device in depth. The microscopic structure of discharges is quantitatively explained by a detailed detector simulation. A 48 x 50 cm 2 floating strip Micromegas is studied in high energy pion beams. Its homogeneity with respect to pulse height, efficiency and spatial resolution is investigated. The good performance in high-rate background environments is demonstrated in cosmic muon tracking measurements with a 6.4 x 6.4 cm 2 floating strip Micromegas under lateral irradiation with 550 kHz 20 MeV proton beams. A floating strip Micromegas doublet with low material budget is developed for ion tracking without limitations from multiple scattering in imaging applications during medical ion therapy. Highly efficient tracking of 20 MeV protons at particle rates of 550 kHz is possible. The reconstruction of the track inclination in a single

  18. Detector Development for the abBA Experiment.

    Science.gov (United States)

    Seo, P-N; Bowman, J D; Mitchell, G S; Penttila, S I; Wilburn, W S

    2005-01-01

    We have developed a new type of field-expansion spectrometer to measure the neutron beta decay correlations (a, b, B, and A). A precision measurement of these correlations places stringent requirements on charged particle detectors. The design employs large area segmented silicon detectors to detect both protons and electrons in coincidence. Other requirements include good energy resolution (electron-backscattering events, and nearly unity efficiency. We report results of testing commercially available surface-barrier silicon detectors for energy resolution and timing performance, and measurement of the dead-layer thickness of ion-implanted silicon detectors with a 3.2 MeV alpha source.

  19. On the characteristics of obliquely propagating electrostatic structures in non-Maxwellian plasmas in the presence of ion pressure anisotropy

    Science.gov (United States)

    Adnan, Muhammad; Qamar, Anisa; Mahmood, Shahzad; Kourakis, Ioannis

    2017-03-01

    The dynamical characteristics of large amplitude ion-acoustic waves are investigated in a magnetized plasma comprising ions presenting space asymmetry in the equation of state and non-Maxwellian electrons. The anisotropic ion pressure is defined using the double adiabatic Chew-Golberger-Low theory. An excess in the superthermal component of the electron population is assumed, in agreement with long-tailed (energetic electron) distribution observations in space plasmas; this is modeled via a kappa-type distribution function. Large electrostatic excitations are assumed to propagate in a direction oblique to the external magnetic field. In the linear (small amplitude) regime, two electrostatic modes are shown to exist. The properties of arbitrary amplitude (nonlinear) obliquely propagating ion-acoustic solitary excitations are thus investigated via a pseudomechanical energy balance analogy, by adopting a Sagdeev potential approach. The combined effect of the ion pressure anisotropy and excess superthermal electrons is shown to alter the parameter region where solitary waves can exist. An excess in the suprathermal particles is thus shown to be associated with solitary waves, which are narrower, faster, and of larger amplitude. Ion pressure anisotropy, on the other hand, affects the amplitude of the solitary waves, which become weaker (in strength), wider (in spatial extension), and thus slower in comparison with the cold ion case.

  20. Novel single-cell mega-size chambers for electrochemical etching of panorama position-sensitive polycarbonate ion image detectors

    Science.gov (United States)

    Sohrabi, Mehdi

    2017-11-01

    A novel development is made here by inventing panorama single-cell mega-size electrochemical etching (MS-ECE) chamber systems for processing panorama position-sensitive mega-size polycarbonate ion image detectors (MS-PCIDs) of potential for many neutron and ion detection applications in particular hydrogen ions or proton tracks and images detected for the first time in polycarbonates in this study. The MS-PCID is simply a large polycarbonate sheet of a desired size. The single-cell MS-ECE invented consists of two large equally sized transparent Plexiglas sheets as chamber walls holding a MS-PCID and the ECE chamber components tightly together. One wall has a large flat stainless steel electrode (dry cell) attached to it which is directly in contact with the MS-PCID and the other wall has a rod electrode with two holes to facilitate feeding and draining out the etching solution from the wet cell. A silicon rubber washer plays the role of the wet cell to hold the etchant and the electrical insulator to isolate the dry cell from the wet cell. A simple 50 Hz-HV home-made generator provides an adequate field strength through the two electrodes across the MS-ECE chamber. Two panorama single-cell MS-ECE chamber systems (circular and rectangular shapes) constructed were efficiently applied to processing the MS-PCIDs for 4π ion emission image detection of different gases in particular hydrogen ions or protons in a 3.5 kJ plasma focus device (PFD as uniquely observed by the unaided eyes). The panorama MS-PCID/MS-ECE image detection systems invented are novel with high potential for many applications in particular as applied to 4π panorama ion emission angular distribution image detection studies in PFD space, some results of which are presented and discussed.

  1. Determination of major sodium iodide symporter (NIS) inhibitors in drinking waters using ion chromatography with conductivity detector.

    Science.gov (United States)

    Cengiz, Mehmet Fatih; Bilgin, Ayse Kevser

    2016-02-20

    Goiter is an important health problem all over the world and iodine deficiency is its most common cause. Perchlorate, thiocyanate and nitrate (called as major NIS inhibitors) are known to competitively inhibit iodide uptake by the thyroid gland and thus, human exposure to major NIS inhibitors is a public health concern. In this study, an ion chromatographic method for the determination of most common NIS inhibitor ions in drinking waters was developed and validated. This is the first study where an analytical method is used for the determination of major NIS inhibitors in drinking water by an ion chromatography system in a single run. Chromatographic separations were achieved with an anion-exchange column and separated ions were identified by a conductivity detector. The method was found to be selective, linear, precise accurate and true for all of interested ions. The limits of the detections (LOD) were estimated at 0.003, 0.004 and 0.025mgL(-1) for perchlorate, thiocyanate and nitrate, respectively. Possible interference ions in drinking waters were examined for the best separation of NIS inhibitors. The excellent method validation data and proficiency test result (Z-score for nitrate: -0.1) of the FAPAS(®) suggested that the developed method could be applied for determination of NIS inhibitor residues in drinking waters. To evaluate the usefulness of the method, 75 drinking water samples from Antalya/Turkey were analyzed for NIS inhibitors. Perchlorate concentrations in the samples ranged from not detected (less than LOD) to 0.07±0.02mgL(-1) and the range of nitrate concentrations were found to be 3.60±0.01mgL(-1) and 47.42±0.40mgL(-1). No thiocyanate residues were detected in tested drinking water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Pulse shape method for the Chimera silicon detectors

    Energy Technology Data Exchange (ETDEWEB)

    Pagano, A.; Arena, N.; Cardella, G.; D' Andrea, M.; Filippo, E. de; Fichera, F.; Giudice, N.; Guardone, N.; Grimaldi, A.; Nicotra, D.; Papa, M.; Pirrone, S.; Politi, G.; Rapicavoli, C.; Rizza, G.; Russotto, P.; Sacca, G.; Urso, S.; Lanzano, G. [Catania Univ., INFN Catania and Dipartimento di Fisica e Astronomia (Italy); Alderighi, M.; Sechi, G. [INFN Milano and Istituto di Fisica Cosmica CNR, Milano (Italy); Amorini, F.; Anzalone, A.; Cali, C.; Campagna, V.; Cavallaro, S.; Di Stefano, A.; Giustolisi, F.; La Guidara, E.; Lanzalone, G.; Maiolino, C.; Porto, F.; Rizzo, F.; Salamone, S. [Catania Univ., INFN-LNS and Dipartimento di Fisica e Astronomia (Italy); Auditore, L.; Trifiro, A.; Trimarchi, M. [Messina Univ., INFN and Dipartimento di Fisica (Italy); Bassini, R.; Boiano, C.; Guazzoni, P.; Russo, S.; Sassi, M.; Zetta, L. [Milano Univ., INFN Milano and Dipartimento di Fisica (Italy); Blicharska, J.; Grzeszczuk, A. [Silesia Univ., Institute of Physics, Katowice (Poland); Chatterjee, M.B. [Saha Institute Of Nuclear Physics, Kolkata (India); Geraci, E.; Zipper, W. [Bologna Univ., INFN Bologna and Dipartimento di Fisica (Italy); Rosato, E.; Vigilante, M. [Napoli Univ., INFN and Dipartimento di Fisica (Italy); Schroder, W.U.; T-ke, J. [Rochester Univ., Dept. of Chemistry, Rochester, N.Y. (United States)

    2003-07-01

    Since January 2003, the 4{pi} CHIMERA (Charged Heavy Ions Mass and Energy Resolving Array) detector in its full configuration has successfully been operated at the 'Catania Laboratori Nazionali del Sud' (LNS) accelerator facility. The detector has been used with a variety of beams from the Superconducting Cyclotron in heavy-ion reaction studies at Fermi bombarding energies. Future experiments with a focus on isospin physics at Fermi energies, planned for both primary and less intense secondary particle beams, suggest the development of new and more versatile experimental particle identification methods. Recent achievements in implementing specific pulse shape particle identification methods for CHIMERA silicon detectors are reported. They suggest an upgrade of the present charge and mass identification capability of CHIMERA by a simple extension of the method. (authors)

  3. Ion-materials interactions and their application

    International Nuclear Information System (INIS)

    Whitlow, H.J.

    1998-01-01

    The interaction of energetic ions and other charged particles with solid matter leads to a wealth of physical processes. This thesis comprises a collection of papers and an introductory commentary, which explore some aspects of how these interactions may be used for: (i) Characterisation of thin surface layers of material, (ii) characterisation of energetic charged particles, and (iii) modification of materials by ion bombardment. In (i) Elastic Recoil Detection using a detector system for measurement of Time of Flight and kinetic energy of recoiling target atoms has been developed as a quantitative method for elemental depth profiling of thin (0.5-1 μm) surface layers. This method has been applied to the study of reactions of metal/III-V structures, which are of importance for the semiconductor industry. (ii) MeV-ion - materials interactions have been used as the basis for developing Si p-i-n detectors for the CHICSi programme which will undertake experimental studies of heavy ion collisions at intermediate energies. This involved development and testing of extremely thin (10-12 μm) Si ΔE detectors for characterising light- and intermediate mass charged particles as well as calibration of Si p-i-n detectors and their susceptibility to radiation damage. (iii) Nuclear Reaction Analysis (NRA) with resonant nuclear reactions has been used to study modification of material with ion beams. In the first study, the accumulation of fluorine in BF 2 + ion implanted WSi 2 solid diffusion sources was investigated. The second study investigated if there was a correlation between photoluminescence and segregation of hydrogen to buried heterojunctions in plasma-etched III-V quantum-well structures. The ion bombardment in this case was during etching in an Ar+CH 4 plasma using an Electron Cyclotron Resonance (ECR) source. (author)

  4. The role of magnetic field fluctuations in nonadiabatic acceleration of ions during dipolarization

    Science.gov (United States)

    Ono, Y.; Nosé, M.; Christon, S. P.; Lui, A. T. Y.

    2009-05-01

    We statistically examine changes in the composition of two different ion species, proton and oxygen ions, in the near-Earth plasma sheet (X = -16 R E ˜ -6 R E ) during substorm-associated dipolarization. We use 10 years of energetic (9-212 keV/e) ion data obtained by the suprathermal ion composition spectrometer (STICS) sensor of the energetic particles and ion composition (EPIC) instrument on board the Geotail spacecraft. The results are as follows: (1) Although the percentage increase in the energy density of O+ ions before and after a dipolarization exceeds that of H+ ions in the low-energy range (9-36 keV/e), this property is not evident in the high-energy range (56-212 keV/e); (2) the energy spectrum of H+ and that of O+ become harder after dipolarization in almost all events; and (3) in some events the energy spectrum of O+ becomes harder than that of H+ as reported by previous studies, and, importantly, in other events, the spectrum of H+ becomes harder than that of O+. In order to investigate what mechanism causes these observational results, we focus on magnetic field fluctuations during dipolarization. It is found that the increase of the spectrum slope is positively correlated with the power of waves whose frequencies are close to the gyrofrequency of H+ or O+, respectively (the correlation coefficient is 0.48 for H+ and 0.68 for O+). In conclusion, ions are nonadiabatically accelerated by the electric field induced by the magnetic field fluctuations whose frequencies are close to their gyrofrequencies.

  5. Interplanetary ions during an energetic storm particle event: The distribution function from solar wind thermal energies to 1.6 MeV

    International Nuclear Information System (INIS)

    Gosling, J.T.; Asbridge, J.R.; Bame, S.J.; Feldman, W.C.; Zwickl, R.D.; Paschmann, G.; Sckopke, N.; Hynds, R.J.

    1981-01-01

    Data from the Los Alamos Scientific Laboratory/Max-Planck-Institut fast plasma experiment on Isee 2 have been combined with data from the European Space Agency/Imperial College/Space Research Laboratory low-energy proton experiment on Isee 3 to obtain for the first time an ion velocity distribution function f(v) extending from solar wind energies (-1 keV) to 1.6 MeV during the postshock phase of an energetic storm particle (ESP) event. This study reveals that f(v) of the ESP population is roughly isotropic in the solar wind frame from solar wind thermal energies out to 1.6 MeV. Emerging smoothly out of the solar wind thermal distribution, the ESP f(v) initially falls with increasing energy as E/sup -2.4/ in the solar wind frame. Above about 40 keV no single power law exponent adequately describes the energy dependence of f(v) in the solar wind frame. Above approx.200 keV in both the spacecraft frame and the solar wind frame, f(v) can be described by an exponential in speed (f(v)proportionale/sup -v/v//sub o/) with v/sub o/ = 1.05 x 10 8 cm s -1 . The ESP event studied (August 27, 1978) was superposed upon a more energetic particle event which was predominantly field-aligned and which was probably of solar origin. Our observations suggest that the ESP population is accelerated directly out of the solar wind thermal population or its quiescent suprathermal tail by a stochastic process associated with the shock wave disturbance. The acceleration mechanism is sufficiently efficient that approx.1% of the solar wind population is accelerated to suprathermal energies. These suprathermal particles have an energy density of approx.290 eV cm -3

  6. The plasma sheet boundary and Ksub(p)

    International Nuclear Information System (INIS)

    Freeman, J.W.

    1975-01-01

    Freeman and Maguire (1967) first drew attention to the intrusion of energetic plasma from the tail to the geostationary orbit during geomagnetically disturbed times. Vasyliunas (1968) reported a correlation between the inward extension of the inner boundary of the plasma sheet and the Ksub(p) index and pointed out that the plasma sheet could occasionally reach the geostationary orbit distance. More recently McIlwain (1972) using the more refined detectors aboard the ATS-5 geostationary space-craft, has emphasized the correlation between the location of the plasma sheet boundary along the ATS orbit and geomagnetic activity. Using some older but unpublished data from the Suprathermal Ion Detector aboard the ATS-1 geostationary satellite, the relation between the local time occurrence of the plasma sheet at the geostationary orbit (6.6Rsub(E)) and Ksub(p) index is reported and then a relationship for the shift in the plasma sheet radial position is derived. (Auth.)

  7. Preliminary Tests of a Paul ion Trap as an Ion Source

    Science.gov (United States)

    Sadat Kiai, S. M.; Zirak, A. R.; Elahi, M.; Adlparvar, S.; Mortazavi, B. N.; Safarien, A.; Farhangi, S.; Sheibani, S.; Alhooie, S.; Khalaj, M. M. A.; Dabirzadeh, A. A.; Ruzbehani, M.; Zahedi, F.

    2010-10-01

    The paper reports on the design and construction of a Paul ion trap as an ion source by using an impact electron ionization technique. Ions are produced in the trap and confined for the specific time which is then extracted and detected by a Faraday cup. Especial electronic configurations are employed between the end caps, ring electrodes, electron gun and a negative voltage for the detector. This configuration allows a constant low level of pure ion source between the pulsed confined ion sources. The present experimental results are based on the production and confinement of Argon ions with good stability and repeatability, but in principle, the technique can be used for various Argon like ions.

  8. Protecting detectors in ALICE

    International Nuclear Information System (INIS)

    Lechman, M.; Augustinus, A.; Chochula, P.; Di Mauro, A.; Stig Jirden, L.; Rosinsky, P.; Schindler, H.; Cataldo, G. de; Pinazza, O.; Kurepin, A.; Moreno, A.

    2012-01-01

    ALICE (A Large Ion Collider Experiment) is one of the big LHC (Large Hadron Collider) experiments at CERN in Geneva. It is composed of many sophisticated and complex detectors mounted very compactly around the beam pipe. Each detector is a unique masterpiece of design, engineering and construction and any damage to it could stop the experiment for months or even for years. It is therefore essential that the detectors are protected from any danger and this is one very important role of the Detector Control System (DCS). One of the main dangers for the detectors is the particle beam itself. Since the detectors are designed to be extremely sensitive to particles they are also vulnerable to any excess of beam conditions provided by the LHC accelerator. The beam protection consists of a combination of hardware interlocks and control software and this paper will describe how this is implemented and handled in ALICE. Tools have also been developed to support operators and shift leaders in the decision making related to beam safety. The gained experiences and conclusions from the individual safety projects are also presented. (authors)

  9. A silicon nanomembrane detector for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) of large proteins.

    Science.gov (United States)

    Park, Jonghoo; Blick, Robert H

    2013-10-11

    We describe a MALDI-TOF ion detector based on freestanding silicon nanomembrane technology. The detector is tested in a commercial MALDI-TOF mass spectrometer with equimolar mixtures of proteins. The operating principle of the nanomembrane detector is based on phonon-assisted field emission from these silicon nanomembranes, in which impinging ion packets excite electrons in the nanomembrane to higher energy states. Thereby the electrons can overcome the vacuum barrier and escape from the surface of the nanomembrane via field emission. Ion detection is demonstrated of apomyoglobin (16,952 Da), aldolase (39,212 Da), bovine serum albumin (66,430 Da), and their equimolar mixtures. In addition to the three intact ions, a large number of fragment ions are also revealed by the silicon nanomembrane detector, which are not observable with conventional detectors.

  10. A Silicon Nanomembrane Detector for Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS of Large Proteins

    Directory of Open Access Journals (Sweden)

    Jonghoo Park

    2013-10-01

    Full Text Available We describe a MALDI-TOF ion detector based on freestanding silicon nanomembrane technology. The detector is tested in a commercial MALDI-TOF mass spectrometer with equimolar mixtures of proteins. The operating principle of the nanomembrane detector is based on phonon-assisted field emission from these silicon nanomembranes, in which impinging ion packets excite electrons in the nanomembrane to higher energy states. Thereby the electrons can overcome the vacuum barrier and escape from the surface of the nanomembrane via field emission. Ion detection is demonstrated of apomyoglobin (16,952 Da, aldolase (39,212 Da, bovine serum albumin (66,430 Da, and their equimolar mixtures. In addition to the three intact ions, a large number of fragment ions are also revealed by the silicon nanomembrane detector, which are not observable with conventional detectors.

  11. THE 15 LAYER SILICON DRIFT DETECTOR TRACKER IN EXPERIMENT 896

    International Nuclear Information System (INIS)

    Pandey, S.U.

    1998-01-01

    Large linear silicon drift detectors have been developed and are in production for use in several experiments. Recently 15 detectors were used as a tracking device in BNL-AGS heavy ion experiment (E896). The detectors were successfully operated in a 6.2 T magnetic field. The behavior of the detectors, such as drift uniformity, resolution, and charge collection efficiency are presented. The effect of the environment on the detector performance is discussed. Some results from the experimental run are presented. The detectors performed well in an experimental environment. This is the first tracking application of these detectors

  12. Time-of-flight mass spectrometer using an imaging detector and a rotating electric field

    International Nuclear Information System (INIS)

    Katayama, Atsushi; Kameo, Yutaka; Nakashima, Mikio

    2008-01-01

    A new technique for minor isotope analysis that uses a rotating electric field and an imaging detector is described. The rotating electric field is generated by six cylindrically arranged plane electrodes with multi-phase sinusoidal wave voltage. When ion packets that are discriminated by time-of-flight enter the rotating electric field, they are circularly deflected, rendering a spiral image on the fluorescent screen of the detector. This spiral image represents m/z values of ions as the position and abundance of ions as brightness. For minor isotopes analyses, the micro channel plate detector under gate control operation is used to eliminate the influence of high intensity of major isotopes. (author)

  13. Geotail observations of plasma sheet ion composition over 16 years: On variations of average plasma ion mass and O+ triggering substorm model

    Science.gov (United States)

    Nosé, M.; Ieda, A.; Christon, S. P.

    2009-07-01

    We examined long-term variations of ion composition in the plasma sheet, using energetic (9.4-212.1 keV/e) ion flux data obtained by the suprathermal ion composition spectrometer (STICS) sensor of the energetic particle and ion composition (EPIC) instrument on board the Geotail spacecraft. EPIC/STICS observations are available from 17 October 1992 for more than 16 years, covering the declining phase of solar cycle 22, all of solar cycle 23, and the early phase of solar cycle 24. This unprecedented long-term data set revealed that (1) the He+/H+ and O+/H+ flux ratios in the plasma sheet were dependent on the F10.7 index; (2) the F10.7 index dependence is stronger for O+/H+ than He+/H+; (3) the O+/H+ flux ratio is also weakly correlated with the ΣKp index; and (4) the He2+/H+ flux ratio in the plasma sheet appeared to show no long-term trend. From these results, we derived empirical equations related to plasma sheet ion composition and the F10.7 index and estimated that the average plasma ion mass changes from ˜1.1 amu during solar minimum to ˜2.8 amu during solar maximum. In such a case, the Alfvén velocity during solar maximum decreases to ˜60% of the solar minimum value. Thus, physical processes in the plasma sheet are considered to be much different between solar minimum and solar maximum. We also compared long-term variation of the plasma sheet ion composition with that of the substorm occurrence rate, which is evaluated by the number of Pi2 pulsations. No correlation or negative correlation was found between them. This result contradicts the O+ triggering substorm model, in which heavy ions in the plasma sheet increase the growth rate of the linear ion tearing mode and play an important role in localization and initiation of substorms. In contrast, O+ ions in the plasma sheet may prevent occurrence of substorms.

  14. Comparison of experimental and theoretical efficiency of HPGe X-ray detector

    International Nuclear Information System (INIS)

    Mohanty, B.P.; Balouria, P.; Garg, M.L.; Nandi, T.K.; Mittal, V.K.; Govil, I.M.

    2008-01-01

    The low energy high purity germanium (HPGe) detectors are being increasingly used for the quantitative estimation of elements using X-ray spectrometric techniques. The softwares used for quantitative estimation normally evaluate model based efficiency of detector using manufacturer supplied detector physical parameters. The present work shows that the manufacturer supplied detector parameters for low energy HPGe detectors need to be verified by comparing model based efficiency with the experimental ones. This is particularly crucial for detectors with ion implanted P type contacts

  15. Characterization of low temperature metallic magnetic calorimeters having gold absorbers with implanted $^{163}$Ho ions

    CERN Document Server

    Gastaldo, L.; von Seggern, F.; Porst, J.-P.; Schäfer, S.; Pies, C.; Kempf, S.; Wolf, T.; Fleischmann, A.; Enss, C.; Herlert, A.; Johnston, K.

    2013-01-01

    For the first time we have investigated the behavior of fully micro-fabricated low temperature metallic magnetic calorimeters (MMCs) after undergoing an ion-implantation process. This experiment had the aim to show the possibility to perform a high precision calorimetric measurement of the energy spectrum following the electron capture of $^{163}$Ho using MMCs having the radioactive $^{163}$Ho ions implanted in the absorber. The implantation of $^{163}$Ho ions was performed at ISOLDE-CERN. The performance of a detector that underwent an ion-implantation process is compared to the one of a detector without implanted ions. The results show that the implantation dose of ions used in this experiment does not compromise the properties of the detector. In addition an optimized detector design for future $^{163}$Ho experiments is presented.

  16. Development of Silicon Drift Detectors using Boron layer technology

    OpenAIRE

    Golshani, N.

    2015-01-01

    Radiation detectors are used in a large variety of fields such as medicine, security, defense, geophysics, industry and physics. They have been developed to detect the energy or position of radiation or charge particles. In Chapter 1 several X-ray detectors were introduced briefly. In gas filled X-ray detectors, incoming photons ionize inert gas and create electron and ions which can be collected at a thin wire anode inside of the chamber. The advantage of this type of detector is the possibi...

  17. Conference on physics from large {gamma}-ray detector arrays

    Energy Technology Data Exchange (ETDEWEB)

    The conference on {open_quotes}Physics from Large {gamma}-ray Detector Arrays{close_quotes} is a continuation of the series of conferences that have been organized every two years by the North American Heavy-ion Laboratories. The aim of the conference this year was to encourage discussion of the physics that can be studied with such large arrays. This volume is the collected proceedings from this conference. It discusses properties of nuclear states which can be created in heavy-ion reactions, and which can be observed via such detector systems.

  18. Measurements of quarkonia with the central detectors of ALICE

    International Nuclear Information System (INIS)

    Sommer, Wolfgang

    2008-01-01

    The production of quarkonia, the bound state of an heavy quark with its anti-particle, has for a long time been seen as a key process to understand the properties of nuclear matter in a relativistic heavy-ion collision. This thesis presents studies on the production of quarkonia in heavy-ion collisions at the new Large Hadron collider (LHC). The focus is set on the decay of J/Psi and Upsilon-states into their di-electronic decay channel, measured within the central detectors of the ALICE detector. (orig.)

  19. Conference on physics from large γ-ray detector arrays

    International Nuclear Information System (INIS)

    1995-01-01

    The conference on open-quotes Physics from Large γ-ray Detector Arraysclose quotes is a continuation of the series of conferences that have been organized every two years by the North American Heavy-ion Laboratories. The aim of the conference this year was to encourage discussion of the physics that can be studied with such large arrays. This volume is the collected proceedings from this conference. It discusses properties of nuclear states which can be created in heavy-ion reactions, and which can be observed via such detector systems

  20. Measurements of quarkonia with the central detectors of ALICE

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, Wolfgang

    2008-03-26

    The production of quarkonia, the bound state of an heavy quark with its anti-particle, has for a long time been seen as a key process to understand the properties of nuclear matter in a relativistic heavy-ion collision. This thesis presents studies on the production of quarkonia in heavy-ion collisions at the new Large Hadron collider (LHC). The focus is set on the decay of J/Psi and Upsilon-states into their di-electronic decay channel, measured within the central detectors of the ALICE detector. (orig.)

  1. STAR detector overview

    Czech Academy of Sciences Publication Activity Database

    Ackermann, K. H.; Adams, N.; Adler, C.; Šumbera, Michal; Zborovský, Imrich

    2003-01-01

    Roč. 499, 2/3 (2003), s. 624-632 ISSN 0168-9002 R&D Projects: GA MŠk ME 475; GA AV ČR KSK1048102 Institutional research plan: CEZ:AV0Z1048901 Keywords : relativistic heavy ions * tracking detectors * electromagnetic calorimeters Subject RIV: BF - Elementary Particles and High Energy Physics Impact factor: 1.166, year: 2003

  2. Ion Colliders

    CERN Document Server

    Fischer, W

    2014-01-01

    High-energy ion colliders are large research tools in nuclear physics to study the Quark-Gluon-Plasma (QGP). The range of collision energy and high luminosity are important design and operational considerations. The experiments also expect flexibility with frequent changes in the collision energy, detector fields, and ion species. Ion species range from protons, including polarized protons in RHIC, to heavy nuclei like gold, lead and uranium. Asymmetric collision combinations (e.g. protons against heavy ions) are also essential. For the creation, acceleration, and storage of bright intense ion beams, limits are set by space charge, charge change, and intrabeam scattering effects, as well as beam losses due to a variety of other phenomena. Currently, there are two operating ion colliders, the Relativistic Heavy Ion Collider (RHIC) at BNL, and the Large Hadron Collider (LHC) at CERN.

  3. Development of triple GEM detector for a heavy ion physics experiment

    International Nuclear Information System (INIS)

    Bhardwaj, A.; Biswal, K.; Gupta, R.

    2015-01-01

    Building and testing of micro-pattern gas detector such as Gas Electron Multiplier (GEM) for several upcoming High-Energy Physics (HEP) experiment projects, is an advance area of research in the field of detector development. We have carried out the long-term stability test and the uniformity of the relative gain over a GEM detector. The method of long-term test and uniformity of the relative gain and the results are presented in this article

  4. Heavy ion beam test results of the silicon charge detector for the CREAM cosmic ray balloon mission

    International Nuclear Information System (INIS)

    Park, I.H.; Ahn, H.S.; Bok, J.B.; Ganel, O.; Hahn, J.H.; Han, W.; Hyun, H.J.; Kim, H.J.; Kim, M.Y.; Kim, Y.J.; Lee, J.K.; Lee, M.H.; Lutz, L.; Min, K.W.; Malinine, A.; Nam, S.W.; Nam, W.; Park, H.; Park, N.H.; Seo, E.S.; Seon, K.I.; Sone, J.H.; Yang, J.; Zinn, S.Y.

    2004-01-01

    The Cosmic Ray Energetics And Mass (CREAM) experiment is designed to measure cosmic ray elemental spectra to help understand the source and acceleration mechanisms of ultra-high-energy cosmic rays. The payload is planned to launch in December 2004 from McMurdo Station, Antarctica as a balloon mission. A Silicon Charge Detector (SCD) was designed and constructed for the CREAM experiment to provide precision charge measurements of incident cosmic rays with a resolution of 0.2 charge unit or better. The SCD was exposed to heavy ion beams at CERN's H2 beam line in November 2003. The results reported here show the SCD performs as designed

  5. Heavy ion beam test results of the silicon charge detector for the CREAM cosmic ray balloon mission

    CERN Document Server

    Park, I H; Bok, J B; Ganel, O; Hahn, J H; Han, W; Hyun, H J; Kim, H J; Kim, M Y; Kim, Y J; Lee, J K; Lutz, L; Malinine, A; Min, K W; Nam, S W; Nam, W; Park, H; Park, N H; Seo, E S; Seon, K I; Sone, J H; Yang, J; Zinn, S Y

    2004-01-01

    The Cosmic Ray Energetics And Mass (CREAM) experiment is designed to measure cosmic ray elemental spectra to help understand the source and acceleration mechanisms of ultra-high-energy cosmic rays. The payload is planned to launch in December 2004 from McMurdo Station, Antarctica as a balloon mission. A Silicon Charge Detector (SCD) was designed and constructed for the CREAM experiment to provide precision charge measurements of incident cosmic rays with a resolution of 0.2 charge unit or better. The SCD was exposed to heavy ion beams at CERN's H2 beam line in November 2003. The results reported here show the SCD performs as designed.

  6. Single ion counting with a MCP (microchannel plate) detector

    Energy Technology Data Exchange (ETDEWEB)

    Tawara, Hiroko; Sasaki, Shinichi; Miyajima, Mitsuhiro [National Lab. for High Energy Physics, Tsukuba, Ibaraki (Japan); Shibamura, Eido

    1996-07-01

    In this study, a single-ion-counting method using alpha-particle-impact ionization of Ar atoms is demonstrated and the preliminary {epsilon}{sub mcp} for Ar ions with incident energies of 3 to 4.7 keV is determined. The single-ion counting by the MCP is aimed to be performed under experimental conditions as follows: (1) A signal from the MCP is reasonably identified as incidence of single Ar-ion. (2) The counting rate of Ar ions is less than 1 s{sup -1}. (3) The incident Ar ions are not focused on a small part of an active area of the MCP, namely, {epsilon}{sub mcp} is determined with respect to the whole active area of the MCP. So far, any absolute detection efficiency has not been reported under these conditions. (J.P.N.)

  7. Methods of selection in heavy ion collisions at Fermi energies and de-excitation modes with the INDRA multi-detector

    International Nuclear Information System (INIS)

    Lautesse, Ph.

    2005-11-01

    The progress made in particle detection, particularly the design of multi-detectors, like INDRA, that cover a solid angle of almost 4π, have given a new impetus to heavy ion collisions. These detectors are demanding for an efficient way of selecting events that have a common history or similar features, for instance the events representing the de-excitation of a unique emitter. The problem is to find the adequate variable on which the discrimination can be based. Different methods are proposed in this work, the common point is that they require efficient models to reproduce and analyse experimental data in order to apprehend the equation of state of nuclear matter. Most of these models are based on the numerically solving of the nuclear Boltzmann equation. The application to the Ni + Ni reaction with an energy ranging from a few A.MeV to more than 50 A.MeV illustrates this work. (A.C.)

  8. Advantages and Limits of 4H-SIC Detectors for High- and Low-Flux Radiations

    Science.gov (United States)

    Sciuto, A.; Torrisi, L.; Cannavò, A.; Mazzillo, M.; Calcagno, L.

    2017-11-01

    Silicon carbide (SiC) detectors based on Schottky diodes were used to monitor low and high fluxes of photons and ions. An appropriate choice of the epilayer thickness and geometry of the surface Schottky contact allows the tailoring and optimizing the detector efficiency. SiC detectors with a continuous front electrode were employed to monitor alpha particles in a low-flux regime emitted by a radioactive source with high energy (>5.0 MeV) or generated in an ion implanter with sub-MeV energy. An energy resolution value of 0.5% was measured in the high energy range, while, at energy below 1.0 MeV, the resolution becomes 10%; these values are close to those measured with a traditional silicon detector. The same SiC devices were used in a high-flux regime to monitor high-energy ions, x-rays and electrons of the plasma generated by a high-intensity (1016 W/cm2) pulsed laser. Furthermore, SiC devices with an interdigit Schottky front electrode were proposed and studied to overcome the limits of the such SiC detectors in the detection of low-energy (˜1.0 keV) ions and photons of the plasmas generated by a low-intensity (1010 W/cm2) pulsed laser. SiC detectors are expected to be a powerful tool for the monitoring of radioactive sources and ion beams produced by accelerators, for a complete characterization of radiations emitted from laser-generated plasmas at high and low temperatures, and for dosimetry in a radioprotection field.

  9. The forward Detectors of the ATLAS experiment

    CERN Document Server

    Vittori, Camilla; The ATLAS collaboration

    2017-01-01

    In this poster, a review of the ATLAS forward detectors operating in the 2015-2016 data taking is given. This includes a description of LUCID, the preferred ATLAS luminosity provider; of the ALFA detector, aimed to measure elastically scattered protons at small angle for the total proton-proton cross section measurement; of the ATLAS Forward Proton project AFP, which was partially installed and took the first data in 2015, and of the Zero Degree Calorimeter ZDC built for the ATLAS Heavy Ions physics program. The near future plans for these detectors will also be addressed.

  10. Performance of high-resolution position-sensitive detectors developed for storage-ring decay experiments

    International Nuclear Information System (INIS)

    Yamaguchi, T.; Suzaki, F.; Izumikawa, T.; Miyazawa, S.; Morimoto, K.; Suzuki, T.; Tokanai, F.; Furuki, H.; Ichihashi, N.; Ichikawa, C.; Kitagawa, A.; Kuboki, T.; Momota, S.; Nagae, D.; Nagashima, M.; Nakamura, Y.; Nishikiori, R.; Niwa, T.; Ohtsubo, T.; Ozawa, A.

    2013-01-01

    Highlights: • Position-sensitive detectors were developed for storage-ring decay spectroscopy. • Fiber scintillation and silicon strip detectors were tested with heavy ion beams. • A new fiber scintillation detector showed an excellent position resolution. • Position and energy detection by silicon strip detectors enable full identification. -- Abstract: As next generation spectroscopic tools, heavy-ion cooler storage rings will be a unique application of highly charged RI beam experiments. Decay spectroscopy of highly charged rare isotopes provides us important information relevant to the stellar conditions, such as for the s- and r-process nucleosynthesis. In-ring decay products of highly charged RI will be momentum-analyzed and reach a position-sensitive detector set-up located outside of the storage orbit. To realize such in-ring decay experiments, we have developed and tested two types of high-resolution position-sensitive detectors: silicon strips and scintillating fibers. The beam test experiments resulted in excellent position resolutions for both detectors, which will be available for future storage-ring experiments

  11. A new detector for deep inelastic physics

    CERN Document Server

    Kostka, Peter; South, David M.

    2014-01-01

    The Large Hadron Electron Collider (LHeC) is a proposed upgrade to the LHC, to provide high energy, high luminosity electron-proton and electron-ion collisions to run concurrently with Phase 2 of the LHC. The key elements of the LHeC detector and the requirements from the physics programme are outlined, followed by a brief description of the baseline LHeC detector design.

  12. Other applications of ion microbeams

    International Nuclear Information System (INIS)

    Cookson, J.A.

    1987-01-01

    The paper concerns the analytical and non-analytical applications of ion microbeams. The analytical applications considered include:-fusion research, environmental studies, ion implantations and criminology, and each is briefly discussed. Non-analytical applications in which nuclear microprobes have been used include:-thickness and uniformity measurements, energy loss radiography, channelling contrast, tomography, topography, ion implantation, and detector testing, and these are also discussed. (UK)

  13. Orion, a high efficiency 4π neutron detector

    International Nuclear Information System (INIS)

    Crema, E.; Piasecki, E.; Wang, X.M.; Doubre, H.; Galin, J.; Guerreau, D.; Pouthas, J.; Saint-Laurent, F.

    1990-01-01

    In intermediate energy heavy ion collisions the multiplicity of emitted neutrons is strongly connected to energy dissipation and to impact parameter. We present the 4π detector ORION, a high efficiency liquid scintillator detector which permits to get information on the multiplicity of neutrons measured event-wise and on the spatial distribution of these neutrons [fr

  14. INDIA: Photon multiplicity detector

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    Full text: The team of Indian scientists from Calcutta's Variable Energy Cyclotron Centre, Bhubaneswar Institute of Physics, Panjab (Chandigarh), Rajasthan (Jaipur) and Jammu in collaboration with GSI Darmstadt have contributed a large and highly granular preshower photon multiplicity detector (PMD) for the WA98 experiment at the CERN SPS proton synchrotron. This experiment studies high energy collisions of lead ions and will measure both charged particle and photon multiplicity in a large overlap region. The motivation for measuring photon multiplicity in ultra-relativistic heavy ion collisions stems from theoretical predictions of changes in the relative production of photons and charged particles in the phase transition of hadronic matter to quarkgluon plasma and its subsequent hadronization. The photon multiplicity detector consists of a matrix of scintillator pads placed in light-tight boxes and mounted behind the lead converter plates. The light from the scintillator pads is transported to the readout system using wavelength shifting (WLS) fibres. Developing on the team's earlier experience with a smaller version for the WA93 experiment (September 1991, page 16), several modifications were incorporated to improve light collection and transport. Use of improved WLS fibres, short WLS pieces to minimize self-absorption, and thermal splicing with long clear fibres were some of the important changes incorporated. Tests showed signficantly improved light collection. The scintillator pads were fabricated at all the five collaborating centres in India and the complicated assembly in the detector box modules carried out at the Variable Energy Cyclotron Centre, Calcutta. More than 400 lead converter plates were machined in Calcutta to rigorous tolerances of 0.2 mm. The assembled detector box modules and lead plates were shipped to CERN in spring 1994 for tests and installation. The WA98 PMD consists of over 50,000 scintillator pads of sizes varying from 15 to

  15. INDIA: Photon multiplicity detector

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1995-01-15

    Full text: The team of Indian scientists from Calcutta's Variable Energy Cyclotron Centre, Bhubaneswar Institute of Physics, Panjab (Chandigarh), Rajasthan (Jaipur) and Jammu in collaboration with GSI Darmstadt have contributed a large and highly granular preshower photon multiplicity detector (PMD) for the WA98 experiment at the CERN SPS proton synchrotron. This experiment studies high energy collisions of lead ions and will measure both charged particle and photon multiplicity in a large overlap region. The motivation for measuring photon multiplicity in ultra-relativistic heavy ion collisions stems from theoretical predictions of changes in the relative production of photons and charged particles in the phase transition of hadronic matter to quarkgluon plasma and its subsequent hadronization. The photon multiplicity detector consists of a matrix of scintillator pads placed in light-tight boxes and mounted behind the lead converter plates. The light from the scintillator pads is transported to the readout system using wavelength shifting (WLS) fibres. Developing on the team's earlier experience with a smaller version for the WA93 experiment (September 1991, page 16), several modifications were incorporated to improve light collection and transport. Use of improved WLS fibres, short WLS pieces to minimize self-absorption, and thermal splicing with long clear fibres were some of the important changes incorporated. Tests showed signficantly improved light collection. The scintillator pads were fabricated at all the five collaborating centres in India and the complicated assembly in the detector box modules carried out at the Variable Energy Cyclotron Centre, Calcutta. More than 400 lead converter plates were machined in Calcutta to rigorous tolerances of 0.2 mm. The assembled detector box modules and lead plates were shipped to CERN in spring 1994 for tests and installation. The WA98 PMD consists of over 50,000 scintillator pads of sizes varying from 15 to 25 mm

  16. Laser diagnostics of H- formation in a magnetic multicusp ion source

    International Nuclear Information System (INIS)

    Young, A.T.; Chen, P.; Kunkel, W.B.; Leung, K.N.; Li, C.Y.; Stutzin, G.C.

    1991-05-01

    The populations of ground electronic state atomic hydrogen and ground electronic state, vibrationally-rotationally excited hydrogen molecules in a negative hydrogen ion source discharge have been measured using vacuum ultraviolet (VUV) laser absorption spectroscopy. Vibrational states up to v=8 and rotational levels as high as J=15 have been measured. The measurements have been made under a range of discharge conditions. The complete vibrational population distribution for v=1-8, J=1 has been obtained. The vibrational distribution appears to be thermalized and does not exhibit a ''plateau'' at the higher vibrational levels, in contrast to most models of this system. In contrast, the high rotational states are populated suprathermally. These determinations indicate that rotationally excited molecules may play an important role in the production of H minus in these sources. 5 refs., 5 figs

  17. Faraday-cup-type lost fast ion detector on Heliotron J

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, S., E-mail: yamamoto.satoshi.6n@kyoto-u.ac.jp; Kobayashi, S.; Nagasaki, K.; Okada, H.; Minami, T.; Kado, S.; Ohshima, S.; Weir, G. M.; Konoshima, S.; Mizuuchi, T. [Institute of Advanced Energy, Kyoto University, Gokasho, Uji, Kyoto 611-0011 (Japan); Ogawa, K.; Isobe, M. [National Institute for Fusion Science, National Institutes of Natural Sciences, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); SOKENDAI (The Graduate University for Advanced Studies), 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); Darrow, D. S. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States); Nakamura, Y.; Ohtani, Y. [Graduate School of Energy Science, Kyoto University, Gokasho, Uji, Kyoto 611-0011 (Japan); Kemmochi, N. [National Institute for Fusion Science, National Institutes of Natural Sciences, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan)

    2016-11-15

    A Faraday-cup type lost-fast ion probe (FLIP) has been designed and installed in Heliotron J for the purpose of the studies of interaction between fast ions and MHD instabilities. The FLIP can measure the co-going fast ions whose energy is in the range of 1.7–42.5 keV (proton) and pitch angle of 90{sup ∘}–140{sup ∘}, especially for fast ions having the injection energy of neutral beam injection (NBI). The FLIP successfully measured the re-entering passing ions and trapped lost-fast ions caused by fast-ion-driven energetic particle modes in NBI heated plasmas.

  18. Capabilities of silicon Shottki barriers and planar detectors in low-energy proton spectometry

    Energy Technology Data Exchange (ETDEWEB)

    Verbitskaya, E M; Eremin, V K; Malyarenko, A M; Sakharov, V I; Serenkov, I T; Strokan, N B; Sukhanov, V L

    1987-05-12

    Dependence of the resolution of surface barrier and planar diffusion silicon detectors on proton energy is investigated. The experiment was conducted at the device, representing the double mass spectrometer with the maximal energy of single-charged ions up to 200 keV. Two advantages of using planar diffusion detectors for light low-energy ion spectrometry is established: high energy resolution and independence of signal amplitude of bias voltage. Background noise represents the main factor dictaiting resolution, but fluctuations of losses in input window are sufficient as well. It was concluded that planar detector application for spectrometry of protons with energy of less than 200 keV would improve the resolution up to 2.2 keV without detector cooling.

  19. Neutron ion temperature measurement

    International Nuclear Information System (INIS)

    Strachan, J.D.; Hendel, H.W.; Lovberg, J.; Nieschmidt, E.B.

    1986-11-01

    One important use of fusion product diagnostics is in the determination of the deuterium ion temperature from the magnitude of the 2.5 MeV d(d,n) 3 He neutron emission. The detectors, calibration methods, and limitations of this technique are reviewed here with emphasis on procedures used at PPPL. In most tokamaks, the ion temperature deduced from neutrons is in reasonable agreement with the ion temperature deduced by other techniques

  20. Characterisation of deuterium spectra from laser driven multi-species sources by employing differentially filtered image plate detectors in Thomson spectrometers

    International Nuclear Information System (INIS)

    Alejo, A.; Kar, S.; Ahmed, H.; Doria, D.; Green, A.; Jung, D.; Lewis, C. L. S.; Nersisyan, G.; Krygier, A. G.; Freeman, R. R.; Clarke, R.; Green, J. S.; Notley, M.; Fernandez, J.; Fuchs, J.; Kleinschmidt, A.; Roth, M.; Morrison, J. T.; Najmudin, Z.; Nakamura, H.

    2014-01-01

    A novel method for characterising the full spectrum of deuteron ions emitted by laser driven multi-species ion sources is discussed. The procedure is based on using differential filtering over the detector of a Thompson parabola ion spectrometer, which enables discrimination of deuterium ions from heavier ion species with the same charge-to-mass ratio (such as C 6+ , O 8+ , etc.). Commonly used Fuji Image plates were used as detectors in the spectrometer, whose absolute response to deuterium ions over a wide range of energies was calibrated by using slotted CR-39 nuclear track detectors. A typical deuterium ion spectrum diagnosed in a recent experimental campaign is presented, which was produced from a thin deuterated plastic foil target irradiated by a high power laser

  1. Characterisation of deuterium spectra from laser driven multi-species sources by employing differentially filtered image plate detectors in Thomson spectrometers

    Science.gov (United States)

    Alejo, A.; Kar, S.; Ahmed, H.; Krygier, A. G.; Doria, D.; Clarke, R.; Fernandez, J.; Freeman, R. R.; Fuchs, J.; Green, A.; Green, J. S.; Jung, D.; Kleinschmidt, A.; Lewis, C. L. S.; Morrison, J. T.; Najmudin, Z.; Nakamura, H.; Nersisyan, G.; Norreys, P.; Notley, M.; Oliver, M.; Roth, M.; Ruiz, J. A.; Vassura, L.; Zepf, M.; Borghesi, M.

    2014-09-01

    A novel method for characterising the full spectrum of deuteron ions emitted by laser driven multi-species ion sources is discussed. The procedure is based on using differential filtering over the detector of a Thompson parabola ion spectrometer, which enables discrimination of deuterium ions from heavier ion species with the same charge-to-mass ratio (such as C6 +, O8 +, etc.). Commonly used Fuji Image plates were used as detectors in the spectrometer, whose absolute response to deuterium ions over a wide range of energies was calibrated by using slotted CR-39 nuclear track detectors. A typical deuterium ion spectrum diagnosed in a recent experimental campaign is presented, which was produced from a thin deuterated plastic foil target irradiated by a high power laser.

  2. Characterisation of deuterium spectra from laser driven multi-species sources by employing differentially filtered image plate detectors in Thomson spectrometers

    Energy Technology Data Exchange (ETDEWEB)

    Alejo, A.; Kar, S., E-mail: s.kar@qub.ac.uk; Ahmed, H.; Doria, D.; Green, A.; Jung, D.; Lewis, C. L. S.; Nersisyan, G. [Centre for Plasma Physics, School of Mathematics and Physics, Queen' s University Belfast, Belfast BT7 1NN (United Kingdom); Krygier, A. G.; Freeman, R. R. [Department of Physics, The Ohio State University, Columbus, Ohio 43210 (United States); Clarke, R.; Green, J. S.; Notley, M. [Central Laser Facility, Rutherford Appleton Laboratory, Didcot, Oxfordshire OX11 0QX (United Kingdom); Fernandez, J. [Central Laser Facility, Rutherford Appleton Laboratory, Didcot, Oxfordshire OX11 0QX (United Kingdom); Instituto de Fusión Nuclear, Universidad Politécnica de Madrid, 28006 Madrid (Spain); Fuchs, J. [LULI, École Polytechnique, CNRS, CEA, UPMC, 91128 Palaiseau (France); Kleinschmidt, A.; Roth, M. [Institut für Kernphysik, Technische Universität Darmstadt, Schloßgartenstrasse 9, D-64289 Darmstadt (Germany); Morrison, J. T. [Propulsion Systems Directorate, Air Force Research Lab, Wright Patterson Air Force Base, Ohio 45433 (United States); Najmudin, Z.; Nakamura, H. [Blackett Laboratory, Department of Physics, Imperial College, London SW7 2AZ (United Kingdom); and others

    2014-09-15

    A novel method for characterising the full spectrum of deuteron ions emitted by laser driven multi-species ion sources is discussed. The procedure is based on using differential filtering over the detector of a Thompson parabola ion spectrometer, which enables discrimination of deuterium ions from heavier ion species with the same charge-to-mass ratio (such as C{sup 6+}, O{sup 8+}, etc.). Commonly used Fuji Image plates were used as detectors in the spectrometer, whose absolute response to deuterium ions over a wide range of energies was calibrated by using slotted CR-39 nuclear track detectors. A typical deuterium ion spectrum diagnosed in a recent experimental campaign is presented, which was produced from a thin deuterated plastic foil target irradiated by a high power laser.

  3. Stair-Step Particle Flux Spectra on the Lunar Surface: Evidence for Nonmonotonic Potentials?

    Science.gov (United States)

    Collier, Michael R.; Newheart, Anastasia; Poppe, Andrew R.; Hills, H. Kent; Farrell, William M.

    2016-01-01

    We present examples of unusual "stair-step" differential flux spectra observed by the Apollo 14 Suprathermal Ion Detector Experiment on the lunar dayside surface in Earth's magnetotail. These spectra exhibit a relatively constant differential flux below some cutoff energy and then drop off precipitously, by about an order of magnitude or more, at higher energies. We propose that these spectra result from photoions accelerated on the lunar dayside by nonmonotonic potentials (i.e.,potentials that do not decay to zero monotonically) and present a model for the expected differential flux. The energy of the cutoff and the magnitude of the differential flux are related to the properties of the local space environment and are consistent with the observed flux spectra. If this interpretation is correct, these surface-based ion observations provide a unique perspective that both complements and enhances the conclusions obtained by remote-sensing orbiter observations on the Moon's exospheric and electrostatic properties.

  4. Neutron detector using sol-gel absorber

    Science.gov (United States)

    Hiller, John M.; Wallace, Steven A.; Dai, Sheng

    1999-01-01

    An neutron detector composed of fissionable material having ions of lithium, uranium, thorium, plutonium, or neptunium, contained within a glass film fabricated using a sol-gel method combined with a particle detector is disclosed. When the glass film is bombarded with neutrons, the fissionable material emits fission particles and electrons. Prompt emitting activated elements yielding a high energy electron contained within a sol-gel glass film in combination with a particle detector is also disclosed. The emissions resulting from neutron bombardment can then be detected using standard UV and particle detection methods well known in the art, such as microchannel plates, channeltrons, and silicon avalanche photodiodes.

  5. Detector Telde for TLD and preparation method

    International Nuclear Information System (INIS)

    Grant, Z.A.; Grube, M.M.; Gotlib, V.I.

    1980-01-01

    The detector consists of a pill composed-on the basis of an ion compound-of a multitude of monocrystalline blocks held together by molecular forces. As an ion compound KCl, LNbO 3 , CaF 2 , LiF and Al 2 O 3 may be used. Manufacturing of the pill is performed by melting. Its surface will be polished. (DG) [de

  6. Silicon-CsI detector array for heavy-ion reactions

    CERN Document Server

    Norbeck, E; Pogodin, P I; Cheng, Y W; Ingram, F D; Bjarki, O; Grévy, S; Magestro, D J; Molen, A M V; Westfall, G D

    2000-01-01

    An array of 60 silicon-CsI(Tl) detector telescopes has been developed along with associated electronics. The close packing of the telescopes required novel designs for the photodiodes and the silicon DELTA E detectors. Newly developed electronics include preamplifiers, shaping amplifiers, test pulse circuitry, and a module to monitor leakage currents in the silicon diodes. The array covers angles from 5 deg. to 18 deg. in the 4 pi Array at the National Superconducting Cyclotron Laboratory at Michigan State University. It measures protons to 150 MeV and has isotopic resolution for intermediate mass nuclei.

  7. X-ray radiography with highly charged ions

    Science.gov (United States)

    Marrs, Roscoe E.

    2000-01-01

    An extremely small (1-250 micron FWHM) beam of slow highly charged ions deexciting on an x-ray production target generates x-ray monochromatic radiation that is passed through a specimen and detected for imaging. The resolution of the x-ray radiograms is improved and such detection is achieved with relatively low dosages of radiation passing through the specimen. An apparatus containing an electron beam ion trap (and modifications thereof) equipped with a focusing column serves as a source of ions that generate radiation projected onto an image detector. Electronic and other detectors are able to detect an increased amount of radiation per pixel than achieved by previous methods and apparati.

  8. Heavy ion radiative capture. A study of the 12C(12C,γ) reaction using a large germanium detector array

    International Nuclear Information System (INIS)

    Jenkins, D.G.; Lister, C.J.; Carpenter, M.P.

    2002-01-01

    A new technique has been developed to investigate the little-explored phenomenon of heavy ion radiative capture. Employing a state-of-the-art germanium detector array (GAMMASPHERE) in a novel fashion as a sum energy calorimeter it is possible to separate the radiative capture channel from overwhelming competition from particle emission channels with exquisite sensitivity. By studying in detail the decay pathways and the intermediate states populated in the decay, it is possible to learn information relevant to the hypothesis of nuclear molecular states. (author)

  9. A large area position-sensitive ionization chamber for heavy-ion-induced reaction studies

    CERN Document Server

    Pant, L M; Dinesh, B V; Thomas, R G; Saxena, A; Sawant, Y S; Choudhury, R K

    2002-01-01

    A large area position-sensitive ionization chamber with a wide dynamic range has been developed to measure the mass, charge and energy of the heavy ions and the fission fragments produced in heavy-ion-induced reactions. The split anode geometry of the detector makes it suitable for both particle identification and energy measurements for heavy ions and fission fragments. The detector has been tested with alpha particles from sup 2 sup 4 sup 1 Am- sup 2 sup 3 sup 9 Pu source, fission fragments from sup 2 sup 5 sup 2 Cf and the heavy-ion beams from the 14UD Mumbai Pelletron accelerator facility. Using this detector, measurements on mass and total kinetic energy distributions in heavy-ion-induced fusion-fission reactions have been carried out for a wide range of excitation energies. Results on deep inelastic collisions and mass-energy correlations on different systems using this detector setup are discussed.

  10. Signal generation in gas detectors

    International Nuclear Information System (INIS)

    Stillman, A.

    1993-01-01

    This tutorial describes the generation of electrical signals in gas detectors. Ionization of the gas by the passage of charged particles generates these signals. Starting with the Bethe-Bloch equation, the treatment is a general introduction to the production of ion-pairs in gas devices. I continue with the characterization of the ionization as an electrical signal, and calculate the signal current in a simple example. Another example demonstrates the effect of space charge on the design of a detector. The AGS Booster ionization profile monitor is a model for this calculation

  11. Simultaneous ion detection in a mass spectrometer with variable mass dispersion

    International Nuclear Information System (INIS)

    Tuithof, H.H.

    1977-01-01

    This thesis mainly describes the ion-optics of a magnetic mass spectrometer system, especially applied to the projection of a significant part of the mass spectrum onto a flat ion-detector. The complete detector consists of a channeltron electron multiplier array with phosphor screen and a Vidicon-multichannel analyzer combination for simultaneous read-out. In order to optimise the spectral range projected onto the channelplate, by varying the mass dispersion and to rotate the oblique angle of the mass focal plane with respect to the detector surface, the sector magnet has been combined with electrostatic and magnetic quadrupole lenses. This detector will find wide application in the analysis of minute sample quantities, in the recording of extremely short ion events (large molecules) and at collision activation mass-spectrometry studies

  12. BROOKHAVEN: Looking towards heavy ion physics

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    July 11-22 were busy days at Brookhaven with a two-week Summer Institute on Relativistic Heavy Ion Physics. After an intensive first week designed to introduce young physicists to high energy heavy ion research, the second week was a workshop on detector technology for Brookhaven's proposed Relativistic Heavy Ion Collider (RHIC), attended by some 150 physicists

  13. Gamma-ray spectroscopy with relativistic exotic heavy-ions

    Indian Academy of Sciences (India)

    Abstract. Feasibility of gamma-ray spectroscopy at relativistic energies with exotic heavy-ions and new generation of germanium detectors (segmented Clover) is discussed. An experiment with such detector array and radioactive is discussed.

  14. Analysis of HgI2 and PbI2 crystals and detectors by particle-induced x-ray emission (PIXE) and ion backscattering spectroscopy (IBS)

    International Nuclear Information System (INIS)

    Bench, G.S.; Heikkinen, D.W.; Antolak, A.J.; Morse, D.H.; Pontau, A.E.; James, R.B.; David, D.C.; Burger, A.; Van Den Berg, L.

    1993-03-01

    The Ion Micro-Analysis Group (IMAG) in Livermore conducts quantitative trace elemental analysis with PIXE and depth profiling with IBS using an MeV ion microbeam. The system has the capability to produce two-dimensional trace element and IBS images. PIXE analyses have been conducted on HgI 2 and PbI 2 crystals and detector materials in order to identify and quantify near surface trace contaminants. IBS measurements have been conducted to investigate elemental depth distributions in various materials. The results of measurements on several different samples are reported and a discussion of factors affecting quantitative in vacuo microanalysis of these materials is presented

  15. Penetrating heavy ion charge and velocity discrimination with a TimePix-based Si detector (for space radiation applications)

    Energy Technology Data Exchange (ETDEWEB)

    Pinsky, Lawrence S., E-mail: pinsky@uh.edu [University of Houston, 4800 Calhoun Blvd., Houston, TX 77204-5005 (United States); Empl, Anton [University of Houston, 4800 Calhoun Blvd., Houston, TX 77204-5005 (United States); Gutierrez, Andrea [University of Montreal, 2905 Chemin des services, Montreal, Que., H3T 1J4 (Canada); Jakubek, Jan [Institute of Experimental and Applied Physics, Czech Technical University, Horska 3a/22, CZ-12800 Prague 2-Albertov (Czech Republic); Kitamura, Hisashi [National Institute for Radiological Sciences, Anagawa 4-9-1, Inage, Chiba 263-8555 (Japan); Miller, Jack [Space Sciences Laboratory, Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Leroy, Claude [University of Montreal, 2905 Chemin des services, Montreal, Que., H3T 1J4 (Canada); Stoffle, Nicholas [University of Houston, 4800 Calhoun Blvd., Houston, TX 77204-5005 (United States); Pospisil, Stanislav [Institute of Experimental and Applied Physics, Czech Technical University, Horska 3a/22, CZ-12800 Prague 2-Albertov (Czech Republic); Uchihori, Yukio; Yasuda, Nakahiro [National Institute for Radiological Sciences, Anagawa 4-9-1, Inage, Chiba 263-8555 (Japan); Zeitlin, Cary [Southwest Research Institute, 6220 Culebra Rd., San Antonio, TX 78238-5166 (United States)

    2011-05-15

    Exposures were made with Medipix2 TimePix-based Si detectors at the HIMAC facility in Japan to explore the potential for discrimination between tracks with differing charges and energies, but with very similar dE/dx values. Data were taken at 15 deg. increments for a number of different beams including 600 and 800 MeV/A Si, 180 MeV/A Ne and 100 MeV/A O. Data were also obtained for 400 MeV/A Si and 500 MeV/A Fe along with 290 and 180 MeV/A N. The TimePix chips have been calibrated to achieve the maximum resolution. Estimates for the angular resolution for these types of tracks are also possible from these data, which are essential in the development of a TimePix-based dosimetric device for use in a space radiation environment. One of the principal objectives of these data runs was to explore the resolution of TimePix-based Si detectors to discriminate between various ions with different energies and charges, but with similar dE/dx values in Si. Analysis of the images obtained shows the clear differences in the {delta}-ray halos for particles with similar dE/dx values but for differing charges and energies. These measurements are part of an ongoing program to explore the range of capabilities of the TimePix-based detector with respect to dosimetry uses in space.

  16. Detector for dimuons produced in the relativistic heavy ion collider

    International Nuclear Information System (INIS)

    Aronson, S.; Igo, G.; Pope, B.; Shor, A.; Young, G.

    1985-01-01

    The use of dimuons as a probe of the quark-gluon plasma is explored. Expected rates and backgrounds in the range of dimuon masses from 0.5 to 4.0 GeV/c 2 are presented. A conceptual design is developed for a detector with sufficient resolution and background rejection to observe dimuons in high multiplicity collisions expected at RHIC. Machine requirements and a cost estimate for the detector are also presented

  17. Study of the energetic proton production in relativistic heavy ions Ne + nuclei collisions, using Diogene detector. Hadronic matter temperature

    International Nuclear Information System (INIS)

    Rahmani, A.

    1988-12-01

    The study of the proton's production differential cross sections, in the collision of relativistic heavy ions, allows to obtain the nuclear-matter temperature and gives information about the nucleons large burst pulses in the nucleus. The chosen thermodynamic model is a generalized approach of the R. Hagedorn model, applied to heavy ions collisions: the nuclear matter is divided in volume elements δV assumed to be in thermal and chemical equilibrium and emitting particles and fragments isotropically, inside their own system. The applied nuclear-matter velocity distribution depended only on the impact parameter and on the relationship between the chemical potential and the temperature. The predictions of this thermodynamic model were compared to the Saturne experimental results, using Diogene detector. The obtained temperature values are similar to those given by D. Hahn and H. Stoker. The proton production cross sections were measured for backward emitting angles. A relationship between the cross sections and the burst pulse distribution in the nuclei was settled [fr

  18. Vibration of signal wires in wire detectors under irradiation

    International Nuclear Information System (INIS)

    Bojko, I.R.; Shelkov, G.A.; Dodonov, V.I.; Ignatenko, M.A.; Nikolenko, M.Yu.

    1995-01-01

    Radiation-induced vibration of signal wires in wire detectors is found and explained. The phenomenon is based on repulsion of a signal wire with a positive potential and a cloud of positive ions that remains after neutralization of the electron part of the avalanche formed in the course of gas amplification. Vibration with a noticeable amplitude may arise from fluctuations of repulsive forces, which act on the wire and whose sources are numerous ion clusters. A formula is obtained which allows wire oscillations to be estimated for all types of wire detectors. Calculation shows that oscillations of signal wires can be substantial for the coordinate accuracy of a detector working in the limited streamer mode at fluxes over 10 5 particles per second per wire. In the proportional mode an average oscillation amplitude can be as large as 20-30 μm at some detector parameters and external radiation fluxes over 10 5 . The experimental investigations show that the proposed model well describes the main features of the phenomenon. 6 refs., 8 figs

  19. Development of an Ion Chamber for Monitoring the Containment of a Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Song, Tae-Yung; Kim, Han-Soo; Park, Se-Hwan; Ha, Jang-Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2008-05-15

    Nuclear power plants need many different types of radiation detectors for different purposes. Neutron detectors are installed inside and outside of the core to check the neutron flux. Scintillation detectors are used to check the fission products included in the liquids and gases of plant system. Geiger-Mueller counters are used for the area radiation monitoring. In addition to the above-mentioned detectors, ion chambers are installed to monitor radiation level of the containment. A few ion chambers are located within the reactor containment to monitor radiation level of an accident case. Therefore, the ion chamber should be capable of monitoring high level radiation dose up to 10{sup 7} R/h. Korea Atomic Energy Research Institute (KAERI) developed an ion chamber for monitoring the radiation dose inside the containment.

  20. Cluster observations and theoretical identification of broadband waves in the auroral region

    Directory of Open Access Journals (Sweden)

    M. Backrud-Ivgren

    2005-12-01

    Full Text Available Broadband waves are common on auroral field lines. We use two different methods to study the polarization of the waves at 10 to 180 Hz observed by the Cluster spacecraft at altitudes of about 4 Earth radii in the nightside auroral region. Observations of electric and magnetic wave fields, together with electron and ion data, are used as input to the methods. We find that much of the wave emissions are consistent with linear waves in homogeneous plasma. Observed waves with a large electric field perpendicular to the geomagnetic field are more common (electrostatic ion cyclotron waves, while ion acoustic waves with a large parallel electric field appear in smaller regions without suprathermal (tens of eV plasma. The regions void of suprathermal plasma are interpreted as parallel potential drops of a few hundred volts.

  1. Characterization of low temperature metallic magnetic calorimeters having gold absorbers with implanted 163Ho ions

    Science.gov (United States)

    Gastaldo, L.; Ranitzsch, P. C.-O.; von Seggern, F.; Porst, J.-P.; Schäfer, S.; Pies, C.; Kempf, S.; Wolf, T.; Fleischmann, A.; Enss, C.; Herlert, A.; Johnston, K.

    2013-05-01

    For the first time we have investigated the behavior of fully micro-fabricated low temperature metallic magnetic calorimeters (MMCs) after undergoing an ion-implantation process. This experiment had the aim to show the possibility to perform a high precision calorimetric measurement of the energy spectrum following the electron capture of 163Ho using MMCs having the radioactive 163Ho ions implanted in the absorber. The isotope 163Ho decays through electron capture to 163Dy and features the smallest known QEC value. This peculiarity makes 163Ho a very interesting candidate to investigate the value of the electron neutrino mass by the analysis of the energy spectrum. The implantation of 163Ho ions was performed at ISOLDE-CERN. The performance of a detector that underwent an ion-implantation process is compared to the one of a detector without implanted ions. The results show that the implantation dose of ions used in this experiment does not compromise the properties of the detector. Moreover the performance of the detector prototype having the 163Ho ions implanted in the absorber is already close to the requirements needed for an experiment with sub-eV sensitivity to the electron neutrino mass. Based on these results, an optimized detector design for future 163Ho experiments is presented.

  2. Characterization of low temperature metallic magnetic calorimeters having gold absorbers with implanted 163Ho ions

    International Nuclear Information System (INIS)

    Gastaldo, L.; Ranitzsch, P.C.-O.; Seggern, F. von; Porst, J.-P.; Schäfer, S.; Pies, C.; Kempf, S.; Wolf, T.; Fleischmann, A.; Enss, C.; Herlert, A.; Johnston, K.

    2013-01-01

    For the first time we have investigated the behavior of fully micro-fabricated low temperature metallic magnetic calorimeters (MMCs) after undergoing an ion-implantation process. This experiment had the aim to show the possibility to perform a high precision calorimetric measurement of the energy spectrum following the electron capture of 163 Ho using MMCs having the radioactive 163 Ho ions implanted in the absorber. The isotope 163 Ho decays through electron capture to 163 Dy and features the smallest known Q EC value. This peculiarity makes 163 Ho a very interesting candidate to investigate the value of the electron neutrino mass by the analysis of the energy spectrum. The implantation of 163 Ho ions was performed at ISOLDE-CERN. The performance of a detector that underwent an ion-implantation process is compared to the one of a detector without implanted ions. The results show that the implantation dose of ions used in this experiment does not compromise the properties of the detector. Moreover the performance of the detector prototype having the 163 Ho ions implanted in the absorber is already close to the requirements needed for an experiment with sub-eV sensitivity to the electron neutrino mass. Based on these results, an optimized detector design for future 163 Ho experiments is presented

  3. Characterisation of a pre-cell hit detector to be used in single cell irradiation experiments at the Lund Nuclear Microprobe

    International Nuclear Information System (INIS)

    Nilsson, Charlotta; Pallon, Jan; Thungstroem, Goeran; Marrero, Natalia Arteaga; Elfman, Mikael; Kristiansson, Per; Nilsson, Christer; Wegden, Marie

    2008-01-01

    This paper describes the characterisation of an ultra-thin silicon semiconductor ΔE detector to be used as a pre-cell ion hit detector in single ion experiments on individual, living cells. The characteristics of interest for this specific application are the hit detection efficiency, which has to be close to 100% to enable bombardment with either a single ion or a counted number of ions, the beam spreading, which should be as small as possible to maintain the targeting accuracy, and the vacuum tightness, since the detector is intended, if possible, to be used simultaneously as vacuum window. The hit detection efficiency was shown to be above 99% when detecting alpha particles or 2 MeV protons, the increase in beam size was about 1 μm and the vacuum tightness was comparable to that of the Si 3 N 4 wafer which is normally used as vacuum window, thus the ΔE detector fulfils the main criteria to function properly as a single ion hit detector.

  4. Comparative studies on PADC polymeric detector treated by gamma radiation and Ar ion beam

    International Nuclear Information System (INIS)

    El-Saftawy, A.A.; Abdel Reheem, A.M.; Kandil, S.A.; Abd El Aal, S.A.; Salama, S.

    2016-01-01

    Highlights: • The induced defects on PADC polymer by low energy Ar ions bombardments have been investigated and evaluated with respect to gamma rays. • Low energy ions in the range of 3 keV is not examined elsewhere. And offers a competitive irradiation tool to gamma. • The structure, hardness and wear resistance enhanced after irradiation. • The optical properties changed, the optical band gap decreased and the refractive index enhanced. • The used ion source proves efficiency in improving surface properties of PADC polymer in comparison to the obtained results by the powerful energy source, gamma rays. - Abstract: In the present study, a comparative analysis and evaluation of the induced defects in polyallyl diglycol carbonate (PADC) polymeric detector exposed to Ar+ and gamma radiation were made. To get insight into the structure defects due to irradiation, X-ray diffraction (XRD) technique was employed. The PADC surface structure changed after irradiation due to the reduction in the surface crystalline structure and the formation of disordered systems. Also, surface morphology changes were traced using scanning electron microscopy (SEM) and showed minor surface irregularities after gamma irradiation and large changes upon Ar+ irradiation. Additionally, micro-hardness and friction coefficient of the irradiated samples were investigated and found to increase after irradiation. UV–vis spectroscopy was used to estimate the optical band gap energy which considered as the basis for calculating the number of conjugated carbon atoms responsible for the blackening effect and color changes took place over the PADC surface. It was found that as the applied dose increased, the band gap decreased and the number of carbon clusters get larger. The refractive index and the dispersion parameters for the studied polymer were calculated and discussed. Also, the induced defects on the polymer surface which serve as a non-radiative centers resulting in reduced

  5. Comparative studies on PADC polymeric detector treated by gamma radiation and Ar ion beam

    Energy Technology Data Exchange (ETDEWEB)

    El-Saftawy, A.A., E-mail: aama1978@yahoo.com [Accelerators & Ion Sources Department, Nuclear Research Center, Atomic Energy Authority, P.O. 13759, Cairo (Egypt); Abdel Reheem, A.M. [Accelerators & Ion Sources Department, Nuclear Research Center, Atomic Energy Authority, P.O. 13759, Cairo (Egypt); Kandil, S.A. [Cyclotron project, Nuclear Research Center, Atomic Energy Authority, P.O. 13759, Cairo (Egypt); Abd El Aal, S.A. [Central Lab. for Elemental & Isotopic Analysis, Nuclear Research Center, Atomic Energy Authority, P.O. 13759, Cairo (Egypt); Salama, S. [Radiation Protection & Civil Defense Department, Nuclear Research Center, Atomic Energy Authority, P.O. 13759, Cairo (Egypt)

    2016-05-15

    Highlights: • The induced defects on PADC polymer by low energy Ar ions bombardments have been investigated and evaluated with respect to gamma rays. • Low energy ions in the range of 3 keV is not examined elsewhere. And offers a competitive irradiation tool to gamma. • The structure, hardness and wear resistance enhanced after irradiation. • The optical properties changed, the optical band gap decreased and the refractive index enhanced. • The used ion source proves efficiency in improving surface properties of PADC polymer in comparison to the obtained results by the powerful energy source, gamma rays. - Abstract: In the present study, a comparative analysis and evaluation of the induced defects in polyallyl diglycol carbonate (PADC) polymeric detector exposed to Ar+ and gamma radiation were made. To get insight into the structure defects due to irradiation, X-ray diffraction (XRD) technique was employed. The PADC surface structure changed after irradiation due to the reduction in the surface crystalline structure and the formation of disordered systems. Also, surface morphology changes were traced using scanning electron microscopy (SEM) and showed minor surface irregularities after gamma irradiation and large changes upon Ar+ irradiation. Additionally, micro-hardness and friction coefficient of the irradiated samples were investigated and found to increase after irradiation. UV–vis spectroscopy was used to estimate the optical band gap energy which considered as the basis for calculating the number of conjugated carbon atoms responsible for the blackening effect and color changes took place over the PADC surface. It was found that as the applied dose increased, the band gap decreased and the number of carbon clusters get larger. The refractive index and the dispersion parameters for the studied polymer were calculated and discussed. Also, the induced defects on the polymer surface which serve as a non-radiative centers resulting in reduced

  6. Results obtained with the passive radiation detectors in the ICCHIBAN-4 experiment

    International Nuclear Information System (INIS)

    Bilski, P.; Horwacik, T.

    2005-05-01

    In frame of the InterComparison of Cosmic rays with Heavy Ions Beams at NIRS (ICCHIBAN) organized at the HIMAC accelerator in Chiba several types of the thermoluminescent detectors (TLD), as well as CR-39 track detectors, were exposed. Four different types of TLDs were used: MTS-7 ( 7 LiF:Mg,Ti), MTS-6 ( 6 LiF:Mg,Ti), MCP-7 ( 7 LiF:Mg,Cu,P) and MTT-7 ( 7 LiF:Mg,Ti with changed activator composition. All TLDs were manufactured at the Institute of Nuclear Physics (INP) in Cracow. The detectors were irradiated with various doses of He, C, Ne and Fe ions. Part of exposures were done in unknown conditions, to test measuring capabilities of the detectors. For analyses of these results, the method of obtaining information on ionisation density of an unknown radiation field, which is based on ratios of responses of different LiF detectors, was successfully used. (author)

  7. A zerotime detector for nuclear fragments using channel electron multiplier plates

    International Nuclear Information System (INIS)

    Sundqvist, B.

    1975-01-01

    The literature on zerotime detectors which use the emission of secondary electrons from a thin foil is reviewed. The construction of a zerotime detector using multiplication of the secondary electrons with two Mullard channel electron multiplier plates (CEMP) in tandem is described. Results of tests of such a detector with α particles from a natural α source are given. Total time resolutions of about 200 ps (FWHM) with a Si(Sb) detector as the stop detector has been achieved. The contribution from the zerotime detector is estimated to be less than 150 ps (FWHM). The application of this detector technique to the construction of a heavy-ion spectrometer and a 8 Be detector is described. (Auth)

  8. An ion cooling and state characterization apparatus for studies of molecular ion dissociative interactions

    International Nuclear Information System (INIS)

    Deng, Shihu; Vane, C R; Bannister, M E; Havener, C C; Meyer, F W; Krause, H F; Hettich, R L; Goeringer, D E; Van Berkel, G J

    2009-01-01

    An experimental capability is being developed at the Oak Ridge National Laboratory Multi-Charged Ion Research Facility (ORNL MIRF) to enable stored cooling and state characterization of molecular ions of essentially any mass. Ions selected from a variety of available sources are injected from the side into a 1.5 meter long electrostatic mirror trap, where excited internal states are cooled by radiative cooling. An electron beam target located near the middle of the ion-trap region, coupled with neutral fragment imaging detector systems at each end of the trap, permits state-specific studies of electron-molecular ion dissociation.

  9. Relativistic heavy ion research at Berkeley

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    The project of a superconducting synchrotron for heavy ions with 1 TeV/amu is described. In this connection the physics is discussed which can be studied by this accelerator. Furthermore, the HISS-heavy ion spectrometer system and the Plastic Ball detector are described. (HSI).

  10. Determination of nuclear tracks parameters on sequentially etched PADC detectors

    Science.gov (United States)

    Horwacik, Tomasz; Bilski, Pawel; Koerner, Christine; Facius, Rainer; Berger, Thomas; Nowak, Tomasz; Reitz, Guenther; Olko, Pawel

    Polyallyl Diglycol Carbonate (PADC) detectors find many applications in radiation protection. One of them is the cosmic radiation dosimetry, where PADC detectors measure the linear energy transfer (LET) spectra of charged particles (from protons to heavy ions), supplementing TLD detectors in the role of passive dosemeter. Calibration exposures to ions of known LET are required to establish a relation between parameters of track observed on the detector and LET of particle creating this track. PADC TASTRAK nuclear track detectors were exposed to 12 C and 56 Fe ions of LET in H2 O between 10 and 544 keV/µm. The exposures took place at the Heavy Ion Medical Accelerator (HIMAC) in Chiba, Japan in the frame of the HIMAC research project "Space Radiation Dosimetry-Ground Based Verification of the MATROSHKA Facility" (20P-240). Detectors were etched in water solution of NaOH with three different temperatures and for various etching times to observe the appearance of etched tracks, the evolution of their parameters and the stability of the etching process. The applied etching times (and the solution's concentrations and temperatures) were: 48, 72, 96, 120 hours (6.25 N NaOH, 50 O C), 20, 40, 60, 80 hours (6.25 N NaOH, 60 O C) and 8, 12, 16, 20 hours (7N NaOH, 70 O C). The analysis of the detectors involved planimetric (2D) measurements of tracks' entrance ellipses and mechanical measurements of bulk layer thickness. Further track parameters, like angle of incidence, track length and etch rate ratio were then calculated. For certain tracks, results of planimetric measurements and calculations were also compared with results of optical track profile (3D) measurements, where not only the track's entrance ellipse but also the location of the track's tip could be directly measured. All these measurements have been performed with the 2D/3D measurement system at DLR. The collected data allow to create sets of V(LET in H2 O) calibration curves suitable for short, intermediate and

  11. Doppler-shift assisted fast ion spectroscopy: a case study for X-ray emission from 277 MeV/u Pb[81+] ions

    International Nuclear Information System (INIS)

    Mokler, P.H.; Stoehlker, T.; Kozhuharov, C.; Moshammer, R.; Rymuza, P.; Stachura, Z.; Warczak, A.

    1994-09-01

    Utilizing the different information from spatially separated segments of high-granular photon detectors the measured (LAB) energy of photons emitted by fast moving ions can be corrected individually for the Doppler effect according to the particular observation angles of each detector segment. By a redundant fitting procedure the center of mass photon energy can be determined with high precision. This new Doppler-shift assisted spectroscopy is explained for the case study of 277.4 MeV/u Pb 82+ ions colliding with a N 2 -gas target at the heavy ion storage ring ESR. Spectroscopic information for hydrogenic Pb 81+ ions is given for the ground-state transitions, for the Balmer transitions, as well as for the total K-binding energy. (orig.)

  12. Enhancements to the Low-Energy Ion Facility at SUNY Geneseo

    Science.gov (United States)

    Barfield, Zachariah; Kostick, Steven; Nagasing, Ethan; Fletcher, Kurt; Padalino, Stephen

    2017-10-01

    The Low Energy Ion Facility at SUNY Geneseo is used for detector development and characterization for inertial confinement fusion diagnostics. The system has been upgraded to improve the ion beam quality by reducing contaminant ions. In the new configuration, ions produced by the Peabody Scientific duoplasmatron ion source are accelerated through a potential, focused into a new NEC analyzing magnet and directed to an angle of 30°. A new einzel lens on the output of the magnet chamber focuses the beam into a scattering chamber with a water-cooled target mount and rotatable detector mount plates. The analyzing magnet has been calibrated for deuteron, 4He+, and 4He2+ ion beams at a range of energies, and no significant hysteresis has been observed. The system can accelerate deuterons to energies up to 25 keV to initiate d-d fusion using a deuterated polymer target. Charged particle spectra with protons, tritons, and 3He ions from d-d fusion have been measured at scattering angles ranging from 55° to 135°. A time-of-flight beamline has been designed to measure the energies of ions elastically scattered at 135°. CEM detectors initiate start and stop signals from secondary electrons produced when low energy ions pass through very thin carbon foils. Funded in part by the U.S. Department of Energy through the Laboratory for Laser Energetics.

  13. Development of a charged particle detector array in Pelletron-LINAC facility

    International Nuclear Information System (INIS)

    John, Bency; Inkar, A.L.; Saxena, A.; Vind, R.P.; Gupta, Y.K.; Biswas, D.C.; Nayak, B.K.; Thomas, R.G.; Danu, L.S.; Choudhury, R.K.; Kailas, S.; Topkar, A.; Venkatramanan, S.; Kumar, Manish; Sunilkumar, S.

    2010-01-01

    A charged particle detector array consisting of 50 Si-CsI detector telescopes for study of heavy-ion reactions is under construction in BARC-TIFR Pelletron-LINAC facility. Developmental work carried out for the detector modules, front-end and pulse shape discrimination electronics, scattering chamber and other mechanical parts are summarized. Some new ideas developed during the course of work are pointed out. (author)

  14. Analysis of a photon number resolving detector based on fluorescence readout of an ion Coulomb crystal quantum memory inside an optical cavity

    DEFF Research Database (Denmark)

    Clausen, Christoph; Sangouard, N.; Drewsen, M.

    2013-01-01

    The ability to detect single photons with a high efficiency is a crucial requirement for various quantum information applications. By combining the storage process of a quantum memory for photons with fluorescence-based quantum state measurement, it is, in principle, possible to achieve high......-efficiency photon counting in large ensembles of atoms. The large number of atoms can, however, pose significant problems in terms of noise stemming from imperfect initial state preparation and off-resonant fluorescence. We identify and analyse a concrete implementation of a photon number resolving detector based...... larger than 93%. Moderate experimental parameters allow for repetition rates of about 3 kHz, limited by the time needed for fluorescence collection and re-cooling of the ions between trials. Our analysis may lead to the first implementation of a photon number resolving detector in atomic ensembles....

  15. Department of Radiation Detectors - Overview

    International Nuclear Information System (INIS)

    Piekoszewski, J.

    1997-01-01

    Work carried out in 1996 in the Department of Radiation Detectors concentrated on three subjects: (i) Semiconductor Detectors (ii) X-ray Tube Generators (iii) Material Modification Using Ion and Plasma Beams. The Departamental objectives are: a search for new types of detectors, adapting modern technologies (especially of industrial microelectronics) to detector manufacturing, producing unique detectors tailored for physics experiments, manufacturing standard detectors for radiation measuring instruments. These objectives were accomplished in 1996 by: research on unique detectors for nuclear physics (e.g. a spherical set of particle detectors silicon ball), detectors for particle identification), development of technology of high-resistivity silicon detectors HRSi (grant proposal), development of thermoelectric cooling systems (grant proposal), research on p-i-n photodiode-based personal dosimeters, study of applicability of industrial planar technology in producing detectors, manufacturing detectors developed in previous years, re-generating and servicing customer detectors of various origin. The Department conducts research on the design and technology involved in producing X-ray generators based on X-ray tubes of special construction. Various tube models and their power supplies were developed. Some work has also been devoted to the detection and dosimetry of X-rays. X-ray tube generators are applied to non-destructive testing and are components of analytical systems such as: X-ray fluorescence chemical composition analysis, gauges of layer thickness and composition stress measurements, on-line control of processes, others where an X-ray tube may replace a radio-isotope source. In 1996, the Department: reviewed the domestic demand for X-ray generators, developed an X-ray generator for diagnosis of ostheroporosis of human limbs, prepared a grant proposal for the development of a new instrument for radiotherapy, the so-called needle-like X-ray tube. (author)

  16. Department of Radiation Detectors - Overview

    Energy Technology Data Exchange (ETDEWEB)

    Piekoszewski, J. [Soltan Inst. for Nuclear Studies, Otwock-Swierk (Poland)

    1997-12-31

    Work carried out in 1996 in the Department of Radiation Detectors concentrated on three subjects: (i) Semiconductor Detectors (ii) X-ray Tube Generators (iii) Material Modification Using Ion and Plasma Beams. The Departamental objectives are: a search for new types of detectors, adapting modern technologies (especially of industrial microelectronics) to detector manufacturing, producing unique detectors tailored for physics experiments, manufacturing standard detectors for radiation measuring instruments. These objectives were accomplished in 1996 by: research on unique detectors for nuclear physics (e.g. a spherical set of particle detectors silicon ball), detectors for particle identification), development of technology of high-resistivity silicon detectors HRSi (grant proposal), development of thermoelectric cooling systems (grant proposal), research on p-i-n photodiode-based personal dosimeters, study of applicability of industrial planar technology in producing detectors, manufacturing detectors developed in previous years, re-generating and servicing customer detectors of various origin. The Department conducts research on the design and technology involved in producing X-ray generators based on X-ray tubes of special construction. Various tube models and their power supplies were developed. Some work has also been devoted to the detection and dosimetry of X-rays. X-ray tube generators are applied to non-destructive testing and are components of analytical systems such as: X-ray fluorescence chemical composition analysis, gauges of layer thickness and composition stress measurements, on-line control of processes, others where an X-ray tube may replace a radio-isotope source. In 1996, the Department: reviewed the domestic demand for X-ray generators, developed an X-ray generator for diagnosis of ostheroporosis of human limbs, prepared a grant proposal for the development of a new instrument for radiotherapy, the so-called needle-like X-ray tube. (author).

  17. Detection of fission products in carbon dioxide by instantaneous ion collection

    International Nuclear Information System (INIS)

    Le Meur, R.; Lorin, A.

    1968-01-01

    This report describes a fission product detector with instantaneous electric collection, capable of analyzing carbon dioxide up to a pressure of 60 bars and at a temperature of 200 C. In contrast to delayed collection detectors, this apparatus makes it possible to collect rubidium and cesium ions as soon as they are formed; this avoids losses due to recombination. The detector has been tested with a fission product source made up of a uranium oxide sample subjected to a neutron flux. The activity of the ions collected as a function of an electric field has been measured for different parameters: pressure, temperature, CO 2 gas flow rate, and the volume of the ion-formation chamber. The sensitivity of this apparatus is compared to that of other fission product detectors. For a low volume-flow rate, e.g. 100 cm 3 sec -1 , its sensitivity for krypton 88 is better than that of a delayed collection detector. An apparatus of this type could be used as a can rupture detector on a reactor with a large number of channels, with a low gas sampling rate per channel. The equipment will be included in the can rupture detector installations in the Fessenheim reactor. (authors) [fr

  18. CHANNELING OF B-IONS IN SILICON

    NARCIS (Netherlands)

    VOS, M; MITCHELL, [No Value; SMULDERS, PJM

    We present new results on the channeling of B ions in Si crystals. Standard surface barrier detectors have been used to record energy spectra for B ions backscattered from the near surface (approximately 1500 angstrom) of a silicon crystal, under perfect, and near axial and planar channeling

  19. Physics with heavy ions at LHC

    International Nuclear Information System (INIS)

    Safarik, K.

    2004-01-01

    We discuss the motivation to study heavy ion collisions at LHC, and the experimental conditions under which detectors will have to operate. A short description of the detectors under construction is given. Physics performance is illustrated in two examples, which will become accessible at LHC energies, jet quenching and heavy-flavor production. (author)

  20. High resolution, position sensitive detector for energetic particle beams

    International Nuclear Information System (INIS)

    Marsh, E.P.; Strathman, M.D.; Reed, D.A.; Odom, R.W.; Morse, D.H.; Pontau, A.E.

    1993-01-01

    The performance and design of an imaging position sensitive, particle beam detector will be presented. The detector is minimally invasive, operates a wide dynamic range (>10 10 ), and exhibits high spatial resolution. The secondary electrons produced when a particle beam passes through a thin foil are imaged using stigmatic ion optics onto a two-dimensional imaging detector. Due to the low scattering cross section of the 6 nm carbon foil the detector is a minimal perturbation on the primary beam. A prototype detector with an image resolution of approximately 5 μm for a field of view of 1 mm has been reported. A higher resolution detector for imaging small beams (<50 μm) with an image resolution of better than 0.5 μm has since been developed and its design is presented. (orig.)

  1. CHICSI [VersionII] - a proposal for a multi-detector ΔE-E particle telescope

    International Nuclear Information System (INIS)

    Guttormsen, M.

    1993-01-01

    The aim of the CHICSI project is to build a silicon ΔE-E telescope system for the measurement of charged ejectiles produced in violent heavy ion collisions in the CELSIUS storage ring. Of particular interest is the detection of intermediate mass fragments in order to investigate the behaviour of nuclear matter under extreme conditions. The present report gives a detailed specification of the CHICSI detector system, to a large extent based on consultations with detector - and electronics company experts. The operation in a storage ring environment requires special attention to the ultra high vacuum condition and target arrangements. The multidetector system will be operated in conjunction with other detector systems as the slow heavy ion recoil detector. 11 refs., 9 figs., 3 tabs

  2. Giessen polarization facility. III. Multi-detector analyzing system

    Energy Technology Data Exchange (ETDEWEB)

    Krause, H H; Stock, R; Arnold, W; Berg, H; Huttel, E; Ulbricht, J; Clausnitzer, G [Giessen Univ. (Germany, F.R.). Strahlenzentrum

    1977-06-15

    An analyzing system with a PDP 11 computer and a digital multiplexer is described. It allows to accept signals from 16 detectors with individual ADCs simultaneously. For measurements of analyzing powers the polarization of the ion beam can be switched to zero with a frequency of 1 kHz. The switching operation additionally controls the handling of the detector pulses. The software contains special programs for the analysis of polarization experiments.

  3. Identification unit for phoswich and phostron detectors

    International Nuclear Information System (INIS)

    Pouxe, J.; Stassi, P.; Dauchy, A.; Giorni, A.; Morand, C.; Chambon, B.; Cheynis, B.; Drain, D.; Pastor, C.

    1984-01-01

    In the last few years the phoswich detector techniques have become a convenient solution to detect light particles emitted in heavy ion induced reactions. Generally the signal delivered by the detectors are integrated within two lapses of time by an analog-to-digital converter triggered by the same signal. When time of flight information is needed the detectors are placed far away from the target and the analog to digital converter must have one gate for each channel because of the jitter in the time of flight of the different particles. As soon as the number of detectors increases this solution becomes too expensive. For this reason a new simple and cheap method is proposed where the particle identification is given by the measurement of data taken from the anode output signal

  4. Single track coincidence measurements of fluorescent and plastic nuclear track detectors in therapeutic carbon beams

    International Nuclear Information System (INIS)

    Osinga, J-M; Jäkel, O; Ambrožová, I; Brabcová, K Pachnerová; Davídková, M; Akselrod, M S; Greilich, S

    2014-01-01

    In this paper we present a method for single track coincidence measurements using two different track detector materials. We employed plastic and fluorescent nuclear track detectors (PNTDs and FNTDs) in the entrance channel of a monoenergetic carbon ion beam covering the therapeutic energy range from 80 to 425 MeV/u. About 99% of all primary particle tracks detected by both detectors were successfully matched, while 1% of the particles were only detected by the FNTDs because of their superior spatial resolution. We conclude that both PNTDs and FNTDs are suitable for clinical carbon beam dosimetry with a detection efficiency of at least 98.82% and 99.83% respectively, if irradiations are performed with low fluence in the entrance channel of the ion beam. The investigated method can be adapted to other nuclear track detectors and offers the possibility to characterize new track detector materials against well-known detectors. Further, by combining two detectors with a restricted working range in the presented way a hybrid-detector system can be created with an extended and optimized working range

  5. Enhancement of concentration range of chromatographically detectable components with array detector mass spectrometry

    Science.gov (United States)

    Enke, Christie

    2013-02-19

    Methods and instruments for high dynamic range analysis of sample components are described. A sample is subjected to time-dependent separation, ionized, and the ions dispersed with a constant integration time across an array of detectors according to the ions m/z values. Each of the detectors in the array has a dynamically adjustable gain or a logarithmic response function, producing an instrument capable of detecting a ratio of responses or 4 or more orders of magnitude.

  6. Determination of electronic stopping powers of 0.05–1 MeV/u {sup 131}Xe ions in C-, Ni- and Au-absorbers with calorimetric low temperature detectors

    Energy Technology Data Exchange (ETDEWEB)

    Echler, A., E-mail: artur.echler@iamp.physik.uni-giessen.de [GSI Helmholtz Center for Heavy Ion Research, Darmstadt (Germany); Institute for Atomic and Molecular Physics, University of Giessen (Germany); Institute for Physics, University of Mainz (Germany); Egelhof, P.; Grabitz, P. [GSI Helmholtz Center for Heavy Ion Research, Darmstadt (Germany); Institute for Physics, University of Mainz (Germany); Kettunen, H. [Department of Physics, University of Jyväskylä (Finland); Kraft-Bermuth, S. [Institute for Atomic and Molecular Physics, University of Giessen (Germany); Laitinen, M. [Department of Physics, University of Jyväskylä (Finland); Müller, K. [Institute for Atomic and Molecular Physics, University of Giessen (Germany); Rossi, M.; Trzaska, W.H.; Virtanen, A. [Department of Physics, University of Jyväskylä (Finland)

    2017-01-15

    A new experimental system for precise determination of electronic stopping powers of heavy ions has been set up at the accelerator laboratory of the University of Jyväskylä. The new setup, combining an established B-ToF system and an array of calorimetric low temperature detectors (CLTDs), has been used for the determination of electronic stopping powers of 0.05–1 MeV/u {sup 131}Xe ions in carbon, nickel and gold. Thereby advantage of the improved linearity and energy resolution of CLTDs as compared to the previously used ionization detector was taken to reduce energy calibration errors and to increase sensitivity for the energy loss determination, in particular at very low energies. The total uncertainties of 3–4% for C- and Ni-targets, and 5–7% for Au-targets, respectively, are dominated by the target properties, i.e. thickness determination and inhomogeneities. The results are compared to data from literature and to predictions of different theoretical computer codes. In the high energy part of the examined energy range the results are in good agreement with previously published data, while new stopping power data for very heavy ions in different Z{sub 2}-materials have been obtained at lower energies. Moreover, unexpectedly strong channeling effects for the transmission of the {sup 131}Xe ions in thin, partly polycrystalline nickel and gold target foils have been observed and investigated.

  7. Modular focusing ring imaging Cherenkov detector for electron-ion collider experiments

    Science.gov (United States)

    Wong, C. P.; Alfred, M.; Allison, L.; Awadi, M.; Azmoun, B.; Barbosa, F.; Barion, L.; Bennett, J.; Brooks, W.; Butler, C.; Cao, T.; Chiu, M.; Cisbani, E.; Contalbrigo, M.; Datta, A.; Del Dotto, A.; Demarteau, M.; Durham, J. M.; Dzhygadlo, R.; Elder, T.; Fields, D.; Furletova, Y.; Gleason, C.; Grosse-Perdekamp, M.; Harris, J.; Haseler, T. O. S.; He, X.; van Hecke, H.; Horn, T.; Hruschka, A.; Huang, J.; Hyde, C.; Ilieva, Y.; Kalicy, G.; Kimball, M.; Kistenev, E.; Kulinich, Y.; Liu, M.; Majka, R.; McKisson, J.; Mendez, R.; Nadel-Turonski, P.; Park, K.; Peters, K.; Rao, T.; Pisani, R.; Qiang, Y.; Rescia, S.; Rossi, P.; Sarajlic, O.; Sarsour, M.; Schwarz, C.; Schwiening, J.; da Silva, C. L.; Smirnov, N.; Stien, H. D.; Stevens, J.; Sukhanov, A.; Syed, S.; Tate, A. C.; Toh, J.; Towell, C. L.; Towell, R. S.; Tsang, T.; Turisini, M.; Wagner, R.; Wang, J.; Woody, C.; Xi, W.; Xie, J.; Zhao, Z. W.; Zihlmann, B.; Zorn, C.

    2017-11-01

    A powerful new electron-ioncollider (EIC) has been recommended in the 2015 Long Range Plan for Nuclear Science for probing the partonic structure inside nucleons and nuclei with unprecedented precision and versatility [1]. EIC detectors are currently under development [2], all of which require hadron identification over a broad kinematic range. A prototype ring imaging Cherenkov detector has been developed for hadron identification in the momentum range from 3 GeV/c to 10 GeV/c. The key feature of this new detector is a compact and modular design, achieved by using aerogel as radiator and a Fresnel lens for ring focusing. In this paper, the results from a beam test of a prototype device at Fermilab are reported.

  8. CHICSi - a compact ultra-high vacuum compatible detector system for nuclear reaction experiments at storage rings. II. Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Golubev, P.; Avdeichikov, V.; Carlen, L.; Jakobsson, B. E-mail: bo.jakobsson@kosufy.lu.se; Siwek, A.; Veldhuizen, E.J. van; Westerberg, L.; Whitlow, H.J

    2003-03-11

    We describe the detectors for identification of charged particles and fragments in CHICSi, a large solid angle multi-telescope system mounted inside an ultra-high vacuum (UHV), cluster-jet target chamber. CHICSi performs nuclear reaction experiments at storage rings. The telescopes consist of a first very thin, 10-14 {mu}m Si detector, a second 300 {mu}m (or possibly 500 {mu}m) ion implanted Si detector supplemented by a 6 mm GSO(Ce) scintillator read out by a photodiode (PD) or by a third 300 {mu}m Si detector. The telescopes provide full charge separation up to Z=17 and mass resolution up to A=9 in the energy range 0.7-60A MeV. The thin p-i-n diode detector, etched out from a 280 {mu}m Si wafer, and the GSO/PD detector, both exclusively developed for CHICSi, provide an energy resolution {<=}8%, while the standard 300 {mu}m detectors have {<=}2% energy resolution. Radiation stability of the Si detectors is confirmed up to an integrated flux of 10{sup 10} alpha particles. The GSO detector has 70% light collection efficiency with the optical coupling to the PD a simple open, 0.2 mm, gap. A new method, developed to perform absolute energy calibration for the GSO/PD detector is presented.

  9. CHICSi - a compact ultra-high vacuum compatible detector system for nuclear reaction experiments at storage rings. II. Detectors

    International Nuclear Information System (INIS)

    Golubev, P.; Avdeichikov, V.; Carlen, L.; Jakobsson, B.; Siwek, A.; Veldhuizen, E.J. van; Westerberg, L.; Whitlow, H.J.

    2003-01-01

    We describe the detectors for identification of charged particles and fragments in CHICSi, a large solid angle multi-telescope system mounted inside an ultra-high vacuum (UHV), cluster-jet target chamber. CHICSi performs nuclear reaction experiments at storage rings. The telescopes consist of a first very thin, 10-14 μm Si detector, a second 300 μm (or possibly 500 μm) ion implanted Si detector supplemented by a 6 mm GSO(Ce) scintillator read out by a photodiode (PD) or by a third 300 μm Si detector. The telescopes provide full charge separation up to Z=17 and mass resolution up to A=9 in the energy range 0.7-60A MeV. The thin p-i-n diode detector, etched out from a 280 μm Si wafer, and the GSO/PD detector, both exclusively developed for CHICSi, provide an energy resolution ≤8%, while the standard 300 μm detectors have ≤2% energy resolution. Radiation stability of the Si detectors is confirmed up to an integrated flux of 10 10 alpha particles. The GSO detector has 70% light collection efficiency with the optical coupling to the PD a simple open, 0.2 mm, gap. A new method, developed to perform absolute energy calibration for the GSO/PD detector is presented

  10. Cluster observations of particle acceleration up to supra-thermal energies in the cusp region related to low-frequency wave activity – possible implications for the substorm initiation process

    Directory of Open Access Journals (Sweden)

    T. A. Fritz

    2008-03-01

    Full Text Available The purpose of our study is to investigate the way particles are accelerated up to supra-thermal energies in the cusp diamagnetic cavities. For this reason we have examined a number of Cluster cusp crossings, originally identified by Zhang et al. (2005, for the years 2001 and 2002 using data from RAPID, STAFF, EFW, CIS, PEACE, and FGM experiments. In the present study we focus on two particular cusp crossings on 25 March 2002 and on 10 April 2002 which demonstrate in a clear way the general characteristics of the events in our survey. Both events exhibit very sharp spatial boundaries seen both in CNO (primarily single-charged oxygen of ionospheric origin based on CIS observations and H+ flux increases within the RAPID energy range with the magnetic field intensity being anti-correlated. Unlike the first event, the second one shows also a moderate electron flux increase. The fact that the duskward electric field Ey has relatively low values <5 mV/m while the local wave activity is very intense provides a strong indication that particle energization is caused primarily by wave-particle interactions. The wave power spectra and propagation parameters during these cusp events are examined in detail. It is concluded that the high ion fluxes and at the same time the presence or absence of any sign of energization in the electrons clearly shows that the particle acceleration depends on the wave power near the local particle gyrofrequency and on the persistence of the wave-particle interaction process before particles escape from cusp region. Furthermore, the continuous existence of energetic O+ ions suggests that energetic O+ populations are of spatial nature at least for the eight events that we have studied so far.

  11. Distribution of O+ ions in the plasma sheet and locations of substorm onsets

    Science.gov (United States)

    Ono, Y.; Christon, S. P.; Frey, H. U.; Lui, A. T. Y.

    2010-09-01

    We discuss the effect of O+ ions on substorm onsets by examining the relation between the substorm onset location and the distribution of the O+/H+ number density ratio before the onset in the various regions within the plasma sheet (-8 RE > XGSM > -32 RE). We use 9-212 keV/e ion flux data observed by Geotail/Energetic Particles and Ion Composition (EPIC)/Suprathermal Ion Composition Spectrometer (STICS) instrument and the IMAGE/Far Ultra-Violet (FUV) substorm onset list presented by Frey et al. [Frey, H. U., S. B. Mende, V. Angelopoulos, and E. F. Donovan (2004), Substorm onset observations by IMAGE-FUV, J. Geophys. Res., 109, A10304, doi:10.1029/2004JA010607]. The results are summarized as follows. Substorm onsets, which we identify by auroral initial brightenings, are likely to occur in the more dusk-(dawn-)ward region when the O+/H+ number density ratio is high in the dusk (dawn) side. This property is observed only in the near-Earth plasma sheet (at -8 RE > XGSM > -14 RE). The above-mentioned property holds in each of two groups: substorm events due to internal instability of the magnetosphere (i.e., internally triggered substorms) and events due to external changes in the solar wind or the interplanetary magnetic field (i.e., externally triggered substorms). Thus, we conclude that the substorm onset location depends on the density of O+ ions in the near-Earth plasma sheet prior to onset, whether the substorm is triggered internally or externally.

  12. Test of radiation hardness of pcCVD detectors

    Energy Technology Data Exchange (ETDEWEB)

    Schlemme, Steffen [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Technische Universitaet Darmstadt (Germany); Enders, Joachim [Technische Universitaet Darmstadt (Germany); Figuera, P.; Salamone, S. [LNS-INFN Catania (Italy); Fruehauf, J.; Kis, Mladen; Kratz, A.; Kurz, N.; Loechner, S.; Nociforo, Chiara; Schirru, Fabio; Szczepanczyk, B.; Traeger, M.; Visinka, R. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Musumarra, A. [LNS-INFN Catania (Italy); University of Catania (Italy)

    2016-07-01

    The new in-flight separator Super-FRS is under construction at the Facility for Antiproton and Ion Research (FAIR, Darmstadt). Ion rates up to 3 x 10{sup 11} {sup 238}U/spill demand an adaption of detectors to a high radiation environment. A test experiment to investigate the radiation hardness of polycrystalline diamond detectors (pcCVD) was performed at the LNS-INFN in Catania using a {sup 12}C beam at 62 MeV/u and intensities of up to 1.5 pnA. The setup consisted of pcCVD strip detectors to measure the beam profile, a single crystal diamond detector to calibrate the ionisation chamber working in current mode as a beam intensity monitor and a pcCVD sample to be irradiated. The IC used was designed for FAIR and showed a stable counting rate allowing us to calibrate and perform beam intensity measurements with it. The total measured counts on the sample were 8.25 x 10{sup 11} counts/mm{sup 2} over a period of 60 hours. Digital waveforms of the pcCVD signals were taken with an oscilloscope and analysed. The results showed no change of the pcCVD signal properties during the entire irradiation.

  13. Recent studies of the ion emission from high-current PF-1000 experiments

    International Nuclear Information System (INIS)

    Skladnik-Sadowska, E.; Sadowski, M.J.; Czaus, K.; Malinowski, K.; Kwiatkowski, R.; Zebrowski, J.; Sadowski, M.J.; Karpinski, L.; Paduch, M.; Scholz, M.; Garkusha, I.E.

    2010-01-01

    The paper describes diagnostics of fast ion beams emitted from a large PF-1000 facility operated at 21...27 kV, 290...480 kJ. Those beams were measured with pinhole cameras and PM-355 nuclear track detectors, placed at different angles to the discharge axis. The measurements showed a complex spatial structure of the fast ion beams. Measurements behind an axial channel in the inner electrode have shown that some ion beams are emitted also in the upstream direction. The ion energy spectra were measured with a miniature Thomson-type spectrometer. Time-resolved measurements of ions were performed with miniature scintillation detectors placed behind a pinhole.

  14. Technical Note: Response measurement for select radiation detectors in magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Reynolds, M., E-mail: michaelreynolds@ualberta.net [Department of Oncology, Medical Physics Division, University of Alberta, 11560 University Avenue, Edmonton, Alberta T6G 1Z2 (Canada); Fallone, B. G. [Department of Medical Physics, Cross Cancer Institute, 11560 University Avenue, Edmonton, Alberta T6G 1Z2, Canada and Departments of Oncology and Physics, University of Alberta, 11560 University Avenue, Edmonton, Alberta T6G 1Z2 (Canada); Rathee, S. [Department of Medical Physics, Cross Cancer Institute, 11560 University Avenue, Edmonton, Alberta T6G 1Z2, Canada and Department of Oncology, Medical Physics Division,University of Alberta, 11560 University Avenue, Edmonton, Alberta T6G 1Z2 (Canada)

    2015-06-15

    Purpose: Dose response to applied magnetic fields for ion chambers and solid state detectors has been investigated previously for the anticipated use in linear accelerator–magnetic resonance devices. In this investigation, the authors present the measured response of selected radiation detectors when the magnetic field is applied in the same direction as the radiation beam, i.e., a longitudinal magnetic field, to verify previous simulation only data. Methods: The dose response of a PR06C ion chamber, PTW60003 diamond detector, and IBA PFD diode detector is measured in a longitudinal magnetic field. The detectors are irradiated with buildup caps and their long axes either parallel or perpendicular to the incident photon beam. In each case, the magnetic field dose response is reported as the ratio of detector signals with to that without an applied longitudinal magnetic field. The magnetic field dose response for each unique orientation as a function of magnetic field strength was then compared to the previous simulation only studies. Results: The measured dose response of each detector in longitudinal magnetic fields shows no discernable response up to near 0.21 T. This result was expected and matches the previously published simulation only results, showing no appreciable dose response with magnetic field. Conclusions: Low field longitudinal magnetic fields have been shown to have little or no effect on the dose response of the detectors investigated and further lend credibility to previous simulation only studies.

  15. CHICSI - a proposal for a multi-detector ΔE-E particle telescope

    International Nuclear Information System (INIS)

    Guttormsen, M.

    1992-01-01

    The aim of the CHICSI project is to build a silicon ΔE-E telescope system for the measurement of charged ejectiles produced in violent heavy ion collisions. Of particular interest is the detection of intermediate mass fragments in order to investigate the behavior of nuclear matter under extreme conditions. The report is a first attempt to determine the design parameters of the multidetector system CHICSI. The detector is intended to be used for experiments at the CELSIUS storage ring. Thus, the operation in a storage ring environment requires special attention to the ultra high vacuum condition and target arrangements. The multidetector system will be operated in conjunction with other detector systems as the slow heavy ion recoil detector. 11 refs., 9 figs., 3 tabs

  16. Temperature effects on radiation damage in plastic detectors

    International Nuclear Information System (INIS)

    Mendoza A, D.

    1996-01-01

    The objective of present work was to study the temperature effect on radiation damage registration in the structure of a Solid State Nuclear Track Detector of the type CR-39. In order to study the radiation damage as a function of irradiation temperature, sheets of CR-39 detectors were irradiated with electron beams, simulating the interaction of positive ions. CR-39 detectors were maintained at a constant temperature from room temperature up to 373 K during irradiation. Two techniques were used from analyzing changes in the detector structure: Electronic Paramagnetic Resonance (EPR) and Infrared Spectroscopy (IR). It was found by EPR analysis that the amount of free radicals decrease as irradiation temperature increases. The IR spectrums show yield of new functional group identified as an hydroxyl group (OH). A proposed model of interaction of radiation with CR-39 detectors is discussed. (Author)

  17. Wavelength dispersive μPIXE setup for the ion microprobe

    Energy Technology Data Exchange (ETDEWEB)

    Fazinić, S., E-mail: stjepko.fazinic@irb.hr [Laboratory for Ion Beam Interactions, Division of Experimental Physics, Rudjer Bošković Institute, Bijenicka cesta 54, 10000 Zagreb (Croatia); Božičević Mihalić, I.; Tadić, T.; Cosic, D.; Jakšić, M. [Laboratory for Ion Beam Interactions, Division of Experimental Physics, Rudjer Bošković Institute, Bijenicka cesta 54, 10000 Zagreb (Croatia); Mudronja, D. [Croatian Conservation Institute, Grškovićeva 23, 10000 Zagreb (Croatia)

    2015-11-15

    We have developed a small wavelength dispersive X-ray spectrometer to explore the possibility of performing chemical speciation on microscopic samples utilizing focused ion beams available at the Rudjer Boskovic Institute ion microprobe. Although PIXE spectra are in principle chemically invariant, small influence of chemical effects could be observed even with Si(Li) or SDD detectors. Such chemical effects can be clearly seen with high resolution crystal X-ray spectrometers having energy resolution of several eV. A dedicated vacuum chamber, housing the diffraction crystal, sample holder and CCD X-ray detector, was constructed and positioned behind the main ion microprobe vacuum chamber. Here we will briefly describe the spectrometer, and illustrate its capabilities on measured K X-ray spectra of selected sulfur compounds. We will also demonstrate its abilities to resolve K and M X-ray lines irresolvable by solid state ED detectors usually used in PIXE.

  18. High energy charged particle registration in CR-39 polycarbonated detector

    International Nuclear Information System (INIS)

    Abdel-Wahab, M.S.; El Enany, N.; El Fiki, S.; Eissa, H.M.; El-Adl, E.H.; El-Feky, M.A.

    1991-01-01

    Track etch rate characteristics of CR-39 plastic detector exposed to 28 Si ions of 670 MeV energy have been investigated. Experimental results were obtained in terms of frequency distribution of the track diameter, track density and bulk etching rate. A dependence of the mean track diameter on energy was found. The application of the radiation effect of heavy ions on CR-39 in the field of radiation detection and dosimetry are discussed. Results indicated that it is possible to produce etchable tracks of 28 Si in this energy range in CR-39. We also report the etching characteristics of these tracks in the CR-39 detector. (orig.) [de

  19. Magnetic Topology and Ion Outflow in Mars' Magnetotail

    Science.gov (United States)

    Mitchell, D. L.; Xu, S.; McFadden, J. P.; Hara, T.; Luhmann, J. G.; Mazelle, C. X.; Andersson, L.; DiBraccio, G. A.; Connerney, J. E. P.

    2017-12-01

    Planetary ion outflow down the Martian magnetotail could be an important atmospheric loss mechanism. This process depends on magnetic connectivity to the day-side ionosphere and on acceleration of ions to escape velocity. The Mars Atmosphere and Volatile Evolution (MAVEN) mission has obtained comprehensive ion, electron, and magnetic field data in Mars' magnetotail. The spacecraft is in a 75°-inclination, elliptical orbit that samples altitudes from 150 to 6200 km. As the orbit precesses, it sweeps through the tail at a variety of altitudes in this range. Data from the Solar Wind Electron Analyzer (SWEA) and Magnetometer (MAG) are used to determine the magnetic field topology in the tail at high cadence (every 2-4 seconds), and in particular whether field lines are open, closed, or draped, and if open whether they have access to the day-side or night-side ionosphere. Simultaneous observations by the Supra-Thermal and Thermal Ion Composition (STATIC) instrument and the Langmuir Probe and Waves (LPW) experiment are used to measure the density, composition, and velocity of planetary plasma on these field lines. We find that magnetic topology in the tail is complex and variable, and is influenced by the IMF polarity and the orientation of Mars' crustal magnetic fields with respect to the Sun. We find that planetary ion outflow occurs on both open and draped field lines. On open field lines, outflow tends to occur parallel to the field line, with colder, denser, and slower outflow on field lines connected to the day-side ionosphere (Fig. 1). On these same field lines (after correction for the spacecraft potential) a shift in the position of the He-II photoelectron feature indicates a 1-Volt parallel electric potential directed away from the planet. Except for H+ and occasionally O+, this potential is insufficient by itself to accelerate planetary ions to escape velocity. Outflow is warmer, less dense, and faster moving on draped field lines. In this case, the ion bulk

  20. High resolution, position sensitive detector for energetic particle beams

    Energy Technology Data Exchange (ETDEWEB)

    Marsh, E P [Charles Evans and Associates, Redwood City, CA (United States); Strathman, M D [Charles Evans and Associates, Redwood City, CA (United States); Reed, D A [Charles Evans and Associates, Redwood City, CA (United States); Odom, R W [Charles Evans and Associates, Redwood City, CA (United States); Morse, D H [Sandia National Labs., Livermore, CA (United States); Pontau, A E [Sandia National Labs., Livermore, CA (United States)

    1993-05-01

    The performance and design of an imaging position sensitive, particle beam detector will be presented. The detector is minimally invasive, operates a wide dynamic range (>10[sup 10]), and exhibits high spatial resolution. The secondary electrons produced when a particle beam passes through a thin foil are imaged using stigmatic ion optics onto a two-dimensional imaging detector. Due to the low scattering cross section of the 6 nm carbon foil the detector is a minimal perturbation on the primary beam. A prototype detector with an image resolution of approximately 5 [mu]m for a field of view of 1 mm has been reported. A higher resolution detector for imaging small beams (<50 [mu]m) with an image resolution of better than 0.5 [mu]m has since been developed and its design is presented. (orig.)