WorldWideScience

Sample records for supply air reset

  1. Simulation of static pressure reset control in comfort ventilation

    DEFF Research Database (Denmark)

    Koulani, Chrysanthi Sofia; Prunescu, Remus Mihail; Hviid, Christian Anker

    2014-01-01

    Variable air volume (VAV) ventilation systems reduce fan power consumption compared to constant air volume (CAV) systems because they supply air according to the airflow demand. However VAV ventilation systems do not take fully into account the potential energy savings as the control strategy...... management system. In this way the operation of central plant equipment is adjusted in real time according to the actual pressure demand; this control scheme can be implemented by the static pressure reset (SPR) method. The SPR control method ensures that at least one damper remains fully opened; thus...... of the art is represented by the method of trim and respond based on pressure alarms. This study investigates the operation of the SPR control method of trim and respond based on pressure alarms in a CO2 demand application where large air volumes are provided to three classrooms. The investigation was based...

  2. Reset Control Systems

    CERN Document Server

    Baños, Alfonso

    2012-01-01

    Reset Control Systems addresses the analysis for reset control treating both its basic form which requires only that the state of the controller be reinitialized to zero (the reset action) each time the tracking error crosses zero (the reset condition), and some useful variations of the reset action (partial reset with fixed or variable reset percentage) and of the reset condition (fixed or variable reset band and anticipative reset). The issues regarding reset control – concepts and motivation; analysis tools; and the application of design methodologies to real-world examples – are given comprehensive coverage. The text opens with an historical perspective which moves from the seminal work of the Clegg integrator and Horowitz FORE to more recent approaches based on impulsive/hybrid control systems and explains the motivation for reset compensation. Preliminary material dealing with notation, basic definitions and results, and with the definition of the control problem under study is also included. The fo...

  3. Wave Pipelining Using Self Reset Logic

    Directory of Open Access Journals (Sweden)

    Miguel E. Litvin

    2008-01-01

    Full Text Available This study presents a novel design approach combining wave pipelining and self reset logic, which provides an elegant solution at high-speed data throughput with significant savings in power and area as compared with other dynamic CMOS logic implementations. To overcome some limitations in SRL art, we employ a new SRL family, namely, dual-rail self reset logic with input disable (DRSRL-ID. These gates depict fairly constant timing parameters, specially the width of the output pulse, for varying fan-out and logic depth, helping accommodate process, supply voltage, and temperature variations (PVT. These properties simplify the implementation of wave pipelined circuits. General timing analysis is provided and compared with previous implementations. Results of circuit implementation are presented together with conclusions and future work.

  4. Converting the reset

    NARCIS (Netherlands)

    J.K. Hoogland (Jiri); C.D.D. Neumann; D. Bloch

    2001-01-01

    textabstractWe give a simple algorithm to incorporate the effects of resets in convertible bond prices, without having to add an extra factor to take into account the value of the reset. Furthermore we show that the effect of a notice period, and additional make-whole features, can be treated in a

  5. Minimum airflow reset of single-duct VAV terminal boxes

    Science.gov (United States)

    Cho, Young-Hum

    Single duct Variable Air Volume (VAV) systems are currently the most widely used type of HVAC system in the United States. When installing such a system, it is critical to determine the minimum airflow set point of the terminal box, as an optimally selected set point will improve the level of thermal comfort and indoor air quality (IAQ) while at the same time lower overall energy costs. In principle, this minimum rate should be calculated according to the minimum ventilation requirement based on ASHRAE standard 62.1 and maximum heating load of the zone. Several factors must be carefully considered when calculating this minimum rate. Terminal boxes with conventional control sequences may result in occupant discomfort and energy waste. If the minimum rate of airflow is set too high, the AHUs will consume excess fan power, and the terminal boxes may cause significant simultaneous room heating and cooling. At the same time, a rate that is too low will result in poor air circulation and indoor air quality in the air-conditioned space. Currently, many scholars are investigating how to change the algorithm of the advanced VAV terminal box controller without retrofitting. Some of these controllers have been found to effectively improve thermal comfort, indoor air quality, and energy efficiency. However, minimum airflow set points have not yet been identified, nor has controller performance been verified in confirmed studies. In this study, control algorithms were developed that automatically identify and reset terminal box minimum airflow set points, thereby improving indoor air quality and thermal comfort levels, and reducing the overall rate of energy consumption. A theoretical analysis of the optimal minimum airflow and discharge air temperature was performed to identify the potential energy benefits of resetting the terminal box minimum airflow set points. Applicable control algorithms for calculating the ideal values for the minimum airflow reset were developed and

  6. Reduction rules for reset/inhibitor nets

    NARCIS (Netherlands)

    Verbeek, H.M.W.; Wynn, M.T.; Aalst, van der W.M.P.; Hofstede, ter A.H.M.

    2010-01-01

    Reset/inhibitor nets are Petri nets extended with reset arcs and inhibitor arcs. These extensions can be used to model cancellation and blocking. A reset arc allows a transition to remove all tokens from a certain place when the transition fires. An inhibitor arc can stop a transition from being

  7. Self-Service Password Reset

    CERN Multimedia

    IT department

    2011-01-01

    Forgotten your password? Throughout the year, one of the most common requests to the Service Desk concerns password resets.  This is especially the case now that we are at the end of the holiday season and many of us return after a long break. Currently, the only way to have your password reset is to call the Service Desk during the week and within the service hours (07:30 to 18:30). Not anymore!   The IT department is putting up a new service that will allow you to reset the password of your primary CERN account by yourself. Note, that you will still be able to request a password reset by calling the Service Desk as usual and that you will still have to do this if your account has been blocked for any reason.  However, the new service provides you with more flexibility and convenience when your memory has failed you. In order to take advantage of this new service, you must:   • Have a valid, active account   • Register in advance an external...

  8. 39 CFR 501.15 - Computerized Meter Resetting System.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Computerized Meter Resetting System. 501.15... AND DISTRIBUTE POSTAGE EVIDENCING SYSTEMS § 501.15 Computerized Meter Resetting System. (a) Description. The Computerized Meter Resetting System (CMRS) permits customers to reset their postage meters at...

  9. Optimization of the air cargo supply chain

    Directory of Open Access Journals (Sweden)

    María Pérez Bernal

    2012-10-01

    Full Text Available Purpose: This paper aims to evaluate and optimize the various operations within the air cargo chain. It pursues to improve the efficiency of the air cargo supply chain and to provide more information to the decision-makers to optimize their fields.Design/methodology/approach: The method used is a process simulation modelling software, WITNESS, which provides information to the decision-makers about the most relevant parameters subject to optimization. The input for the simulation is obtained from a qualitative analysis of the air cargo supply chain with the involved agents and from a study of the external trade by air mode, given that their behaviour depend on the location. The case study is focused on a particular location, the Case of Zaragoza Airport (Spain.Findings: This paper demonstrates that efficiency of the air cargo supply chain can increase by leveraging several parameters such as bottlenecks, resources or warehouses.Originality/value: It explores the use of a simulation modeling software originally intended for manufacturing processes and extended to support decision making processes in the area of air cargo.

  10. The performance and subjective responses of call-center operators with new and used supply air filters at two outdoor air supply rates

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Wyon, David; Fanger, Povl Ole

    2004-01-01

    A 2X2 replicated field intervention experiment was conducted in a call-center providing a telephone directory service: outdoor air supply rate was adjusted to be 8% of the total airflow of 430 l/s (3.5/h)and the supply air filters were either new or had been in place for 6 months. One of these in......A 2X2 replicated field intervention experiment was conducted in a call-center providing a telephone directory service: outdoor air supply rate was adjusted to be 8% of the total airflow of 430 l/s (3.5/h)and the supply air filters were either new or had been in place for 6 months. One...

  11. Impact of the duct static pressure reset control strategy on the energy consumption by the HVAC system

    Directory of Open Access Journals (Sweden)

    Walaszczyk Juliusz

    2017-01-01

    Full Text Available This article addresses different duct static pressure control strategies which could be implemented in variable air volume air-conditioning systems (VAV. Two pressure reset control strategies are compared to the commonly used control solution based on the “Constant static pressure” method. First pressure reset control strategy, known as PID Control, uses signals from VAV boxes controllers to reset duct static pressure in a way that one of the VAV dampers is maintained almost entirely open. Second strategy decreases static pressure setpoint until an adjustable number of pressure requests occur. As a response to the certain amount of requests, static pressure setpoint is increased. This strategy is called Trim & Respond. Both static pressure reset control strategies described in this paper are considered to have more significant potential for energy savings than the “Constant static pressure” method. In order to validate this potential, several simulations for different control strategies were carried out and the obtained results are compared and analysed. The theoretical limit of the energy savings - set of the optimal control actions, was estimated with Nelder-Mead algorithm and also presented in this article. General description of the static pressure control strategies "Constant static pressure", PID Control and Trim & Respond is given.

  12. Transistor reset preamplifier for high-rate high-resolution spectroscopy

    International Nuclear Information System (INIS)

    Landis, D.A.; Cork, C.P.; Madden, N.W.; Goulding, F.S.

    1981-10-01

    Pulsed transistor reset of high resolution charge sensitive preamplifiers used in cooled semiconductor spectrometers can sometimes have an advantage over pulsed light reset systems. Several versions of transistor reset spectrometers using both silicon and germanium detectors have been built. This paper discusses the advantages of the transistor reset system and illustrates several configurations of the packages used for the FET and reset transistor. It also describes the preamplifer circuit and shows the performance of the spectrometer at high rates

  13. Rational use of supply air in residential buildings

    DEFF Research Database (Denmark)

    Mortensen, Dorthe Kragsig; Nielsen, Toke Rammer; Svendsen, Svend

    2009-01-01

    The ventilation rate influences the air quality by determining the intensity of pollution sources. This paper compared the intensity of the sensory pollution during occupied hours in an apartment ventilated by a constant air volume system and demand controlled ventilation systems controlled by oc...... by occupancy. The systems supplied the same total volume of air daily. It was found that the supply air could be used more rationally by redistributing it according to occupancy compared to maintaining a constant ventilation rate during all hours....

  14. Effect of warm air supplied facially on occupants' comfort

    Energy Technology Data Exchange (ETDEWEB)

    Kaczmarczyk, J. [Department of Heating, Ventilation and Dust Removal Technology, Silesian University of Technology, Konarskiego 20, PL-44-101 Gliwice (Poland); Melikov, A.; Sliva, D. [Department of Civil Engineering, Technical University of Denmark, International Centre for Indoor Environment and Energy, Nils Koppels Alle, DTU, Building 402, 2800 Lyngby (Denmark)

    2010-04-15

    Human response to air movement supplied locally towards the face was studied in a room with an air temperature of 20 C and a relative humidity of 30%. Thirty-two human subjects were exposed to three conditions: calm environment and facially supplied airflow at 21 C and at 26 C. The air was supplied with a constant velocity of 0.4 m/s by means of personalized ventilation towards the face of the subjects. The airflow at 21 C decreased the subjects' thermal sensation and increased draught discomfort, but improved slightly the perceived air quality. Heating of the supplied air by 6 K (temperature increase by 4 K at the target area) above the room air temperature decreased the draught discomfort, improved subjects' thermal comfort and only slightly decreased the perceived air quality. Elevated velocity and temperature of the localized airflow caused an increase of nose dryness intensity and number of eye irritation reports. Results suggest that increasing the temperature of the air locally supplied to the breathing zone by only a few degrees above the room air temperature will improve occupants' thermal comfort and will diminish draught discomfort. This strategy will extend the applicability of personalized ventilation aiming to supply clean air for breathing at the lower end of the temperature range recommended in the standards. Providing individual control is essential in order to avoid discomfort for the most sensitive occupants. (author)

  15. Effect of warm air supplied facially on occupants' comfort

    DEFF Research Database (Denmark)

    Kaczmarczyk, J.; Melikov, Arsen Krikor; Sliva,, D.

    2010-01-01

    was supplied with a constant velocity of 0.4 m/s by means of personalized ventilation towards the face of the subjects. The airflow at 21 °C decreased the subjects' thermal sensation and increased draught discomfort, but improved slightly the perceived air quality. Heating of the supplied air by 6 K...... (temperature increase by 4 K at the target area) above the room air temperature decreased the draught discomfort, improved subjects' thermal comfort and only slightly decreased the perceived air quality. Elevated velocity and temperature of the localized airflow caused an increase of nose dryness intensity...... and number of eye irritation reports. Results suggest that increasing the temperature of the air locally supplied to the breathing zone by only a few degrees above the room air temperature will improve occupants' thermal comfort and will diminish draught discomfort. This strategy will extend...

  16. Air/fuel supply system for use in a gas turbine engine

    Science.gov (United States)

    Fox, Timothy A; Schilp, Reinhard; Gambacorta, Domenico

    2014-06-17

    A fuel injector for use in a gas turbine engine combustor assembly. The fuel injector includes a main body and a fuel supply structure. The main body has an inlet end and an outlet end and defines a longitudinal axis extending between the outlet and inlet ends. The main body comprises a plurality of air/fuel passages extending therethrough, each air/fuel passage including an inlet that receives air from a source of air and an outlet. The fuel supply structure communicates with and supplies fuel to the air/fuel passages for providing an air/fuel mixture within each air/fuel passage. The air/fuel mixtures exit the main body through respective air/fuel passage outlets.

  17. Change in the CERN account password reset procedure

    CERN Multimedia

    IT Department

    2008-01-01

    Since 19 August 2008, the security of the CERN account password reset procedure has been strengthened. As a result, users asking to have their password reset by the Computing Helpdesk will be asked to provide some personal information prior to resetting their CERN account password. Please note that all relevant information about CERN accounts and passwords can be found at http://cern.ch/it-dep/AccountsandpasswordsatCERN.htm Thank you in advance for your cooperation. IT Department

  18. Change in the CERN account password reset procedure

    CERN Multimedia

    IT Department

    2008-01-01

    From Since 19 August 19th 2008, the security of the CERN account password reset procedure has been strengthened. As a result, users requesting to have their password reset by the Computing Helpdesk will be asked to provide some private personal information prior to resetting their CERN account password. Please note that all relevant information about the CERN account and password can be found at http://cern.ch/it-dep/AccountsandpasswordsatCERN.htm Thank you in advance for your cooperation. IT Department

  19. Description of Supply Openings in Numerical Models for Room Air Distribution

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    This paper discusses various possibilities for describing supply openings in numerical models of room air distribution.......This paper discusses various possibilities for describing supply openings in numerical models of room air distribution....

  20. A study of reset mode in advanced alarm system simulator

    International Nuclear Information System (INIS)

    Yenn, T. C.; Hwang, S. L.; Huang, F. H.; Yu, A. C.; Hsu, C. C.; Huang, H. W.

    2006-01-01

    An automation function has been widely applied in main control room of nuclear power plants. That leads to a new issue of human-automation interaction, which considers human operational performance in automated systems. In this research is the automation alarm reset in the advanced alarm system (AAS) of Advanced Nuclear Power Plant in Taiwan. Since alarms are very crucial for the understanding of the status of the plant as well as the reset function of alarm system will be changed from fully manual to fully automatic, it is very important to test and evaluate the performance and the effect of reset modes in AAS. The purpose of this paper is to evaluate the impact of the auto-reset alarm system on the plant performance and on operators' preference and task load. To develop a dynamic simulator as an AAS was conducted to compare manual and automatic reset function of alarm system on task performance and subjective ratings of task workload, comprehension, and preference. The simulation includes PCTRAN model and alarm software processing. The final results revealed that, using the auto-reset mode, participants had lower task load index (TLX) on effort in the first test trial and was more satisfied in multiple tasks condition. In contrast, using manual reset mode, participants were more satisfied on alarm handling, monitoring, and decision making. In other words, either reset mode in the study has unique features to assist operator, but is insufficient. The reset function in AAS therefore should be very flexible. Additionally, the experimental results also pointed out that the user interfaces need to be improved. Those experiences will be helpful for human factors verification and validation in the near future. (authors)

  1. Air-drop blood supply in the French Army.

    Science.gov (United States)

    Javaudin, Olivier; Baillon, A; Varin, N; Martinaud, C; Pouget, T; Civadier, C; Clavier, B; Sailliol, A

    2018-02-12

    Haemorrhagic shock remains the leading cause of preventable death in overseas and austere settings. Transfusion of blood components is critical in the management of this kind of injury. For French naval and ground military units, this supply often takes too long considering the short shelf-life of red blood cell concentrates (RBCs) and the limited duration of transport in cooling containers (five to six days). Air-drop supply could be an alternative to overcome these difficulties on the condition that air-drop does not cause damage to blood units. After a period of study and technical development of packaging, four air-drops at medium and high altitudes were performed with an aircraft of the French Air Force. After this, one air-drop was carried out at medium altitude with 10 RBCs and 10 French lyophilised plasma (FLYP). A second air-drop was performed with a soldier carrying one FLYP unit at 12 000 feet. For these air-drops real blood products were used, and quality control testing and temperature monitoring were performed. The temperatures inside the containers were within the normal ranges. Visual inspection indicated that transfusion packaging and dumped products did not undergo deterioration. The quality control data on RBCs and FLYP, including haemostasis, suggested no difference before and after air-drop. The operational implementation of the air-drop of blood products seems to be one of the solutions for the supply of blood products in military austere settings or far forward on battlefield, allowing safe and early transfusion. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. Well-Posedness of Reset Control Systems as State-Dependent Impulsive Dynamical Systems

    Directory of Open Access Journals (Sweden)

    Alfonso Baños

    2012-01-01

    existence and uniqueness of solutions, and in particular to the resetting times to be well defined and distinct. A sufficient condition is developed for a reset system to have well-posed resetting times, which is also a sufficient condition for avoiding Zeno solutions and, thus, for a reset control system to be well-posed.

  3. Desynchronizing electrical and sensory coordinated reset neuromodulation

    OpenAIRE

    Popovych, Oleksandr V.; Tass, Peter A.

    2012-01-01

    Coordinated reset (CR) stimulation is a desynchronizing stimulation technique based on timely coordinated phase resets of sub-populations of a synchronized neuronal ensemble. It has initially been computationally developed for electrical deep brain stimulation (DBS), to enable an effective desynchronization and unlearning of pathological synchrony and connectivity (anti-kindling). Here we computationally show for ensembles of spiking and bursting model neurons interacting via excitatory and i...

  4. Desynchronizing Electrical and Sensory Coordinated Reset Neuromodulation

    OpenAIRE

    Oleksandr V. Popovych; Peter A. Tass; Peter A. Tass

    2012-01-01

    Coordinated reset (CR) stimulation is a desynchronizing stimulation technique based on timely coordinated phase resets of sub-populations of a synchronized neuronal ensemble. It has initially been computationally developed for electrical deep brain stimulation (DBS),to enable an effective desynchronization and unlearning of pathological synchrony and connectivity (anti-kindling). Here we computationally show for ensembles of spiking and bursting model neurons interacting via excitatory and in...

  5. Endurance Enhancement and High Speed Set/Reset of 50 nm Generation HfO2 Based Resistive Random Access Memory Cell by Intelligent Set/Reset Pulse Shape Optimization and Verify Scheme

    Science.gov (United States)

    Higuchi, Kazuhide; Miyaji, Kousuke; Johguchi, Koh; Takeuchi, Ken

    2012-02-01

    This paper proposes a verify-programming method for the resistive random access memory (ReRAM) cell which achieves a 50-times higher endurance and a fast set and reset compared with the conventional method. The proposed verify-programming method uses the incremental pulse width with turnback (IPWWT) for the reset and the incremental voltage with turnback (IVWT) for the set. With the combination of IPWWT reset and IVWT set, the endurance-cycle increases from 48 ×103 to 2444 ×103 cycles. Furthermore, the measured data retention-time after 20 ×103 set/reset cycles is estimated to be 10 years. Additionally, the filamentary based physical model is proposed to explain the set/reset failure mechanism with various set/reset pulse shapes. The reset pulse width and set voltage correspond to the width and length of the conductive-filament, respectively. Consequently, since the proposed IPWWT and IVWT recover set and reset failures of ReRAM cells, the endurance-cycles are improved.

  6. Overcurrent Abuse of Primary Prismatic Zinc–Air Battery Cells Studying Air Supply Effects on Performance and Safety Shut-Down

    Directory of Open Access Journals (Sweden)

    Fredrik Larsson

    2017-01-01

    Full Text Available Overcurrent abuse has been performed on commercial 48 Ah primary prismatic zinc (Zn–Air battery cells with full air supply as well as with shut-off air supply. Compared to other battery technologies, e.g., lithium-ion batteries, metal–air batteries offer the possibility to physically stop the battery operation by stopping its air supply, thus offering an additional protection against severe battery damage in the case of, e.g., an accidental short circuit. This method may also reduce the electrical hazard in a larger battery system since, by stopping the air supply, the voltage can be brought to zero while maintaining the energy capacity of the battery. Measurements of overdischarge currents and current cut-off by suffocation have been performed to assess the safety of this type of Zn–air battery. The time to get to zero battery voltage is shown to mainly be determined by the volume of air trapped in the cell.

  7. A high-current, high-voltage power supply with special output current waveform for APS injector synchrotron dipole magnets

    International Nuclear Information System (INIS)

    Fathizadeh, M.; Despe, O.D.; McGhee, D.G.; Mills, F.E.; Turner, L.R.

    1991-01-01

    This paper describes a high-voltage, high-current power supply for the injector synchrotron dipole magnets at APS. In order to reset the dipole magnets in each cycle two different current waveforms are suggested. The first current waveform consists of three sections, namely: dc-reset, linear ramp, and recovery sections where injection is done ''on the fly''. The second current waveform consists of six different sections, dc-reset, transition to injection level, injection flat level, parabolic, linear ramp and recovery sections. The effect of such waveforms on the beam is discussed and the power supply limitations to follow such waveforms are given. The power supply limitations are due to the power components and control loops. The reference for the current loop is generated by a DAC which is discussed

  8. Path-integral formalism for stochastic resetting: Exactly solved examples and shortcuts to confinement.

    Science.gov (United States)

    Roldán, Édgar; Gupta, Shamik

    2017-08-01

    We study the dynamics of overdamped Brownian particles diffusing in conservative force fields and undergoing stochastic resetting to a given location at a generic space-dependent rate of resetting. We present a systematic approach involving path integrals and elements of renewal theory that allows us to derive analytical expressions for a variety of statistics of the dynamics such as (i) the propagator prior to first reset, (ii) the distribution of the first-reset time, and (iii) the spatial distribution of the particle at long times. We apply our approach to several representative and hitherto unexplored examples of resetting dynamics. A particularly interesting example for which we find analytical expressions for the statistics of resetting is that of a Brownian particle trapped in a harmonic potential with a rate of resetting that depends on the instantaneous energy of the particle. We find that using energy-dependent resetting processes is more effective in achieving spatial confinement of Brownian particles on a faster time scale than performing quenches of parameters of the harmonic potential.

  9. Reduced heat stress in offices in the tropics using solar powered drying of the supply air

    DEFF Research Database (Denmark)

    Gunnarsen, Lars; Santos, A M B

    2002-01-01

    air may facilitate personal cooling by increased evaporation of sweat. Heat acclimatized people with efficient sweating may in particular benefit from this cooling. A prototype solar powered supply system for dried-only air was made. Air from the system was mixed with room air, heated to six different...... content of room air, temperature of supply air and moisture content of supply air was developed based on the experiments. Reduction of moisture content in the supply air by 1.6 g/kg had the same effect as lowering the operative temperature by 1 degree C. The solar-powered system for supplying dry air...... is a low-cost alternative to traditional air conditioning in hot and humid regions....

  10. INTERACTION OF AIR TRANSPORTATION AND FUEL-SUPPLY COMPANIES

    Directory of Open Access Journals (Sweden)

    I. P. Zheleznaya

    2014-01-01

    Full Text Available The article describes the role of aviation fuel in the life of air transport. Fueling industry worldwide solves two main tasks - ensuring the safety and economy of air traffic. In Russia, there is one more task of airlines fuel supply. The article deals with fuel pricing taking into consideration today's realities.

  11. Reset charge sensitive amplifier for NaI(Tl) gamma-ray spectrometer

    International Nuclear Information System (INIS)

    Zeng, Guoqiang; Tan, Chengjun; Li, Qiang; Ge, Liangquan; Liu, Xiyao; Luo, Qun

    2015-01-01

    The time constant of the output signal of the front-end readout circuit of a traditional gamma-ray spectrometer with a NaI(Tl)+PMT structure is affected by temperature, measurement environment and the signal transmission cable, so it is difficult to get a good resolution spectrum, especially at higher counting rates. In this paper, a reset charge sensitive amplifier (RCSA) is designed for the gamma-ray spectrometer with a NaI(Tl)+PMT structure. The designed RCSA outputs a step signal, thus enabling the acquisition of double-exponential signals with a stable time constant by using the next stage of a CR differentiating circuit. The designed RCSA is mainly composed of a basic amplifying circuit, a reset circuit and a dark current compensation circuit. It provides the output step signal through the integration of the PMT output charge signal. When the amplitude of the step signal exceeds a preset voltage threshold, it triggers the reset circuit to generate a reset pulse (about 5 µs pulse width) to reset the output signal. Experimental results demonstrated that the designed RCSA achieves a charge sensitivity of 4.26×10 10 V/C, with a zero capacitance noise of 51.09 fC and a noise slope of 1.98 fC/pF. Supported by the digital shaping algorithm of the digital multi-channel analyzer (DMCA), it can maintain good energy resolution with high counting rates up to 150 kcps and with a temperature range from −19 °C to 50 °C. - Highlights: • A new reset type charge sensitive amplifier for gamma-ray spectrometer based on a photomultiplier tube is proposed. • Reset circuit formed by constant current source output a fixed width pulse to reset charge sensitive amplifier. • Photomultiplier tube dark current compensation circuit could increase the pulse through rate by decreasing reset frequency. • This amplifier outputs a step function signal that could match next stage circuit easily

  12. Voice Biometrics as a Way to Self-service Password Reset

    Science.gov (United States)

    Hohgräfe, Bernd; Jacobi, Sebastian

    Password resets are time consuming. Especially when urgent jobs need to be done, it is cumbersome to inform the user helpdesk, to identify oneself and then to wait for response. It is easy to enter a wrong password multiple times, which leads to the blocking of the application. Voice biometrics is an easy and secure way for individuals to reset their own password. Read more about how you can ease the burden of your user helpdesk and how voice biometric password resets benefit your expense situation without harming your security.

  13. Specifications and test procedures for airline-type supplied-air suits

    International Nuclear Information System (INIS)

    Revoir, W.H.; Pritchard, J.A.; Davis, T.O.; Richards, C.P.; Wheat, L.D.

    1975-05-01

    Procedures and requirements have been established to permit airline-type supplied-air suits needed by contractors of the Energy Research and Development Administration to be tested for performance by the Respirator Research and Development Section, Industrial Hygiene Group, of the Los Alamos Scientific Laboratory, and to have the adequacy of the performance of these devices evaluated by the Los Alamos Scientific Laboratory Respirator Advisory Committee. Test equipment, test methods, and performance criteria for airline-type supplied-air suits are prescribed. (U.S.)

  14. The semaphore codes attached to a Turing machine via resets and their various limits

    OpenAIRE

    Rhodes, John; Schilling, Anne; Silva, Pedro V.

    2016-01-01

    We introduce semaphore codes associated to a Turing machine via resets. Semaphore codes provide an approximation theory for resets. In this paper we generalize the set-up of our previous paper "Random walks on semaphore codes and delay de Bruijn semigroups" to the infinite case by taking the profinite limit of $k$-resets to obtain $(-\\omega)$-resets. We mention how this opens new avenues to attack the P versus NP problem.

  15. Effects of the Factory Reset on Mobile Devices

    Directory of Open Access Journals (Sweden)

    Riqui Schwamm

    2014-09-01

    Full Text Available Mobile devices usually provide a “factory-reset” tool to erase user-specific data from the main secondary storage. 9 Apple iPhones, 10 Android devices, and 2 BlackBerry devices were tested in the first systematic evaluation of the effectiveness of factory resets. Tests used the Cellebrite UME-36 Pro with the UFED Physical Analyzer, the Bulk Extractor open-source tool, and our own programs for extracting metadata, classifying file paths, and comparing them between images. Two phones were subjected to more detailed analysis. Results showed that many kinds of data were removed by the resets, but much user-specific configuration data was left. Android devices did poorly at removing user documents and media, and occasional surprising user data was left on all devices including photo images, audio, documents, phone numbers, email addresses, geolocation data, configuration data, and keys. A conclusion is that reset devices can still provide some useful information to a forensic investigation.

  16. Experimental and Theoretical Investigation of Impinging Jet Ventilation at Different Cross Sectional Area of Supply Air Duct

    Directory of Open Access Journals (Sweden)

    Ala'a Abbas Mahdi

    2018-03-01

    Full Text Available  An experimental and computational analysis of temperature and velocity distribution in an office room have been studied. Office room of dimensions (3m x 1.75m x 3m with two cross sectional types of supply air duct in the experimental part and three different cross sectional types of supply air duct in the theoretical part is usual as a tested model. The RNG k-  turbulence model was employed to solve the governing equations numerically and validated by comparing the numerical results with experimental data. The impinging jet concept has been proposed as a new ventilation strategy for use in office and industrial buildings. The present work focuses on evaluating the performance of a new impinging jet ventilation. In a theoretical study three types of supply air duct are adopted which are square supply air duct (Type-I, semi-elliptic supply air duct (Type-II and rectangle supply air duct (Type-III for two cases of air outlet terminal height from room foot level, 0.14h (case-I & 0.1h (case-II. The third type (rectangle duct gives lowest effective and discomfort conditions when compared with the other two types. This study investigated a number of factors influencing draught discomfort and temperature stratification in an office environment equipped with impinging jet ventilation IJV. The factors considered to be: shape of the air supply device, supply airflow rate and supply air temperature. Acceptable Air Distribution Performance Index (ADPI, effective temperature, and ventilation efficiency obtained that the square cross sectional area of supply air duct at 0.1h (case-II height from foot level gives more acceptable indoor air quality and human thermal comfort when compared with the other types. Also, this type gives good air distribution system not only promotes a comfortable and healthy environment for occupants, but also contributes to energy conservation.

  17. 42 CFR 84.149 - Type C supplied-air respirator, demand and pressure demand class; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Type C supplied-air respirator, demand and pressure demand class; minimum requirements. 84.149 Section 84.149 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT... OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.149 Type C supplied-air respirator...

  18. Demand control on room level of the supply air temperature in an air heating and ventilation system

    DEFF Research Database (Denmark)

    Polak, Joanna; Afshari, Alireza; Bergsøe, Niels Christian

    2017-01-01

    air heating and ventilation system in a high performance single family house using BSim simulation software. The provision of the desired thermal conditions in different rooms was examined. Results show that the new control strategy can facilitate maintaining of desired temperatures in various rooms......The aim of this study was to investigate a new strategy for control of supply air temperature in an integrated air heating and ventilation system. The new strategy enables demand control of supply air temperature in individual rooms. The study is based on detailed dynamic simulations of a combined....... Moreover, this control strategy enables controlled temperature differentiation between rooms within the house and therefore provides flexibility and better balance in heat delivery. Consequently, the thermal conditions in the building can be improved....

  19. Supply air filters after the nuclear reactor accident at Chernobyl

    International Nuclear Information System (INIS)

    Bonka, H.

    1989-01-01

    In the case of increased activity concentration in the air supply air filters are the facility compounds where enhanced activity is collected. Therefore, it was understandable that the people put questions about the doses caused by supply air filters after the nuclear reactor accident at Chernobyl. When comparing the local dose rate at a distance of 1 m in front of filters with the outdoor local dose rate due to dry deposited radionuclides, nearly the same local dose rate results assuming an air flow rate of approx. 60 m 3 /h. Supposing a 10 hours stay at a distance of 1 m in front of filters and an air flow rate of approx. 5000 m 3 /h the same dose is obtained after a 10 days delay as the dose due to outdoor inhalation. At Aachen, the local dose rate near to filters increased up to approx. 10 μSv/h. After a suitable time delay of one month filters could be rejected like normal waste. A review is given on individual measured values

  20. Effects of Linear Falling Ramp Reset Pulse on Addressing Operation in AC PDP

    International Nuclear Information System (INIS)

    Liu Zujun; Liang Zhihu; Liu Chunliang; Meng Lingguo

    2006-01-01

    The effects of linear falling ramp reset pulse related to addressing operation in an alternating current plasma display panel (AC PDP) were studied. The wall charge waveforms were measured by the electrode balance method in a 12-inch coplanar AC PDP. The wall charge waveforms show the relationship between the slope ratio of the falling ramp reset pulse and the wall charges at the end of the falling ramp reset pulse which influences the addressing stability. Then the effects of the slope ratio of the linear falling ramp reset pulse on the addressing voltage and addressing time were investigated. The experimental results show that the minimum addressing voltage increases with the increase of the slope ratio of the falling ramp reset pulse, and so does the minimum addressing time. Based on the experimental results, the optimization of the addressing time and the slope ratio of the falling ramp pulse is discussed

  1. Desynchronizing electrical and sensory coordinated reset neuromodulation.

    Science.gov (United States)

    Popovych, Oleksandr V; Tass, Peter A

    2012-01-01

    Coordinated reset (CR) stimulation is a desynchronizing stimulation technique based on timely coordinated phase resets of sub-populations of a synchronized neuronal ensemble. It has initially been computationally developed for electrical deep brain stimulation (DBS), to enable an effective desynchronization and unlearning of pathological synchrony and connectivity (anti-kindling). Here we computationally show for ensembles of spiking and bursting model neurons interacting via excitatory and inhibitory adaptive synapses that a phase reset of neuronal populations as well as a desynchronization and an anti-kindling can robustly be achieved by direct electrical stimulation or indirect (synaptically-mediated) excitatory and inhibitory stimulation. Our findings are relevant for DBS as well as for sensory stimulation in neurological disorders characterized by pathological neuronal synchrony. Based on the obtained results, we may expect that the local effects in the vicinity of a depth electrode (realized by direct stimulation of the neurons' somata or stimulation of axon terminals) and the non-local CR effects (realized by stimulation of excitatory or inhibitory efferent fibers) of deep brain CR neuromodulation may be similar or even identical. Furthermore, our results indicate that an effective desynchronization and anti-kindling can even be achieved by non-invasive, sensory CR neuromodulation. We discuss the concept of sensory CR neuromodulation in the context of neurological disorders.

  2. Desynchronizing Electrical and Sensory Coordinated Reset Neuromodulation

    Directory of Open Access Journals (Sweden)

    Oleksandr V. Popovych

    2012-03-01

    Full Text Available Coordinated reset (CR stimulation is a desynchronizing stimulation technique based on timely coordinated phase resets of sub-populations of a synchronized neuronal ensemble. It has initially been computationally developed for electrical deep brain stimulation (DBS,to enable an effective desynchronization and unlearning of pathological synchrony and connectivity (anti-kindling. Here we computationally show for ensembles of spiking and bursting model neurons interacting via excitatory and inhibitory adaptive synapses that a phase reset of neuronal populations as well as a desynchronization and an anti-kindling can robustly be achieved by direct electrical stimulation or indirect (synaptically-mediated excitatory and inhibitory stimulation.Our findings are relevant for DBS as well as for sensory stimulation in neurological disorders characterized by pathological neuronalsynchrony. Based on the obtained results, we may expect that the local effects in the vicinity of a depth electrode (realized by direct stimulation of the neurons' somata or stimulation of axon terminals and the non-local CR effects (realized by stimulation of excitatory or inhibitory efferent fibers of deep brain CR neuromodulation may be similar or even identical. Furthermore, ourresults indicate that an effective desynchronization and anti-kindlingcan even be achieved by non-invasive, sensory CR neuromodulation. We discuss the concept of sensory CR neuromodulation in the context of neurological disorders.

  3. Acoustic Coordinated Reset Neuromodulation in a Real Life Patient Population with Chronic Tonal Tinnitus

    Science.gov (United States)

    Hauptmann, Christian; Ströbel, Armin; Williams, Mark; Patel, Nitesh; Wurzer, Hannes; von Stackelberg, Tatjana; Brinkmann, Uwe; Langguth, Berthold; Tass, Peter A.

    2015-01-01

    Purpose. Primary tinnitus has a severe negative influence on the quality of life of a significant portion of the general population. Acoustic coordinated reset neuromodulation is designed to induce a long-lasting reduction of tinnitus symptoms. To test acoustic coordinated reset neuromodulation as a treatment for chronic, tonal tinnitus under real life conditions, an outpatient study “RESET Real Life” was commissioned by ANM GmbH. Herein we present the results of this study. Methods. In a prospective, open-label, nonrandomized, noncontrolled multicenter clinical study with 200 chronic tinnitus patients, tinnitus questionnaire TBF-12 and Global Clinical Improvement-Impression Scale (CGI-I7) are used to study the safety and efficacy of acoustic coordinated reset neuromodulation. 189 patients completed the last 12-month visit, 11 patients dropped out (8 because of nontreatment related reasons; 2 because tinnitus did not change; and 1 because tinnitus got louder). Results. Acoustic coordinated reset neuromodulation caused a statistically and clinically significant decrease in TBF-12 scores as well as in CGI-I7 after 12 months of therapy under real life conditions. There were no persistent adverse events reported that were related to the therapy. Conclusion. The field study “RESET Real Life” provides evidence for safety and efficacy of acoustic coordinated reset neuromodulation in a prospective, open-label, real life setting. PMID:26568958

  4. Defense Logistics. Preliminary Observations on the Army's Implementation of Its Equipment Reset Strategies

    National Research Council Canada - National Science Library

    Solis, William M

    2007-01-01

    .... In order to provide effective oversight of the Army's implementation of its equipment reset strategies and to plan for future reset initiatives, the Congress needs to be assured that the funds...

  5. Experimental study on airflow fluctuation characteristic of an underfloor air supply terminal unit

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jinping [School of Electric Power, South China University of Technology, Guangzhou 510640 (China); State Key Laboratory of Subtropical Building Science, South China University of Technology, Guangzhou 510640 (China); Wu, Yanfang [Design Institute of Guangzhou Metro Corporation, Guangzhou 510010 (China)

    2010-11-15

    In order to investigate dynamic characteristic of underfloor air supply terminal unit, an IFV900A hot-wire anemometer was used to measure the corresponding velocity field. Turbulence intensity and power spectrum density exponent of air velocity signal were analyzed. The result showed that the outlet velocity distribution of underfloor air supply terminal unit was uniform. With increment of height, the velocity distribution trends to be uniform. Two velocity attenuation regions appear during airflow development. Turbulence intensity changes obviously with height. It is lower than that of mechanical wind. Turbulence intensity goes up with the increment of jetting distance. Power spectrum density exponent trends to the value of natural wind with increase of jetting distance and decrease of wind velocity. The exponent value approaches to the value of typical natural wind for the air velocity is 0.5 m/s under high supply air rate. With airflow diffusion, the fluctuation characteristic of airflow varies obviously with the jetting direction. The fluctuation characteristic of airflow changes to that of natural wind with the increase of height which can improve comfort of indoor environment. (author)

  6. Recensie "The Great Reset" : Richard Florida

    NARCIS (Netherlands)

    Roy van Dalm

    2010-01-01

    Like the Great Depression and the Long Depression before it, experts have viewed prolonged economic downturns as crises. In The Great Reset , bestselling author Richard Florida argues that we should instead see the recent recession as an opportunity to create entirely new ways of working and living

  7. Reset Tree-Based Optical Fault Detection

    Directory of Open Access Journals (Sweden)

    Howon Kim

    2013-05-01

    Full Text Available In this paper, we present a new reset tree-based scheme to protect cryptographic hardware against optical fault injection attacks. As one of the most powerful invasive attacks on cryptographic hardware, optical fault attacks cause semiconductors to misbehave by injecting high-energy light into a decapped integrated circuit. The contaminated result from the affected chip is then used to reveal secret information, such as a key, from the cryptographic hardware. Since the advent of such attacks, various countermeasures have been proposed. Although most of these countermeasures are strong, there is still the possibility of attack. In this paper, we present a novel optical fault detection scheme that utilizes the buffers on a circuit’s reset signal tree as a fault detection sensor. To evaluate our proposal, we model radiation-induced currents into circuit components and perform a SPICE simulation. The proposed scheme is expected to be used as a supplemental security tool.

  8. Resetting dynamic behaviour of pipework systems

    International Nuclear Information System (INIS)

    Gaudin, M.

    1997-01-01

    Resetting models is applied to electricity generating plant pipework systems. A frequency approach to the problem is made in an original way thanks to the use of precise dynamic rigidity matrices. The method assumes two kinds of unknown: the usually processed mechanical characteristics (Young's Modulus, density etc.) and new resetting parameters acting on the dynamic behaviour of unknown connections. As the latter have a very wide range of possible variation, they benefit from a change of variable which allows the assumptions formulated to be complied with. The minimized cost function is based on a error in load. The frequencies required for building it are automatically selected thanks to different tests on measurements. Minimization uses a sensitivity technique linked with a method of least standard squares. The method has been programmed in Fortran 90 within the CIRCUS code and tried out on various examples which were simulated and sound effects cases as well as an actual case. (author)

  9. Application of ground-to-air heat exchanger for preheating of supply air

    Science.gov (United States)

    Sorokins, Juris; Borodinecs, Anatolijs; Zemitis, Jurgis

    2017-10-01

    This study focuses on assessing the contribution of the passive ground-coupled air heat exchanger system to decreasing the energy consumption of air conditioning and ventilation systems for office buildings in the Latvian climate conditions. The theoretical part of the thesis deals with methods of office building ventilation, supply air preheating and heat recovery as well as particularities of using ground-coupled air heat exchangers, their design parameters and their joint impact on the thermal performance. The engineering project part includes a ventilation system for an office building with an integrated ground-coupled air heat exchanger. By simulating energy consumption of the ventilation system for a duration of one year, the thesis analyzes the contribution of the heat exchanger to the overall energy consumption, which totals 9.53 MWh and 4.02 MWh a year, according to the desired parameters of the indoor climate. The possible alternative heat recovery solutions are investigated to reach by European Regional Development Fund project Nr.1.1.1.1/16/A/048 “NEARLY ZERO ENERGY SOLUTIONS FOR UNCLASSIFIED BUILDINGS”.

  10. FPS camera sync and reset chassis

    International Nuclear Information System (INIS)

    Yates, G.J.

    1980-06-01

    The sync and reset chassis provides all the circuitry required to synchronize an event to be studied, a remote free-running focus projection and scanning (FPS) data-acquisition TV camera, and a video signal recording system. The functions, design, and operation of this chassis are described in detail

  11. Neural and Behavioral Evidence for an Online Resetting Process in Visual Working Memory.

    Science.gov (United States)

    Balaban, Halely; Luria, Roy

    2017-02-01

    Visual working memory (VWM) guides behavior by holding a set of active representations and modifying them according to changes in the environment. This updating process relies on a unique mapping between each VWM representation and an actual object in the environment. Here, we destroyed this mapping by either presenting a coherent object but then breaking it into independent parts or presenting an object but then abruptly replacing it with a different object. This allowed us to introduce the neural marker and behavioral consequence of an online resetting process in humans' VWM. Across seven experiments, we demonstrate that this resetting process involves abandoning the old VWM contents because they no longer correspond to the objects in the environment. Then, VWM encodes the novel information and reestablishes the correspondence between the new representations and the objects. The resetting process was marked by a unique neural signature: a sharp drop in the amplitude of the electrophysiological index of VWM contents (the contralateral delay activity), presumably indicating the loss of the existent object-to-representation mappings. This marker was missing when an updating process occurred. Moreover, when tracking moving items, VWM failed to detect salient changes in the object's shape when these changes occurred during the resetting process. This happened despite the object being fully visible, presumably because the mapping between the object and a VWM representation was lost. Importantly, we show that resetting, its neural marker, and the behavioral cost it entails, are specific to situations that involve a destruction of the objects-to-representations correspondence. Visual working memory (VWM) maintains task-relevant information in an online state. Previous studies showed that VWM representations are accessed and modified after changes in the environment. Here, we show that this updating process critically depends on an ongoing mapping between the

  12. A parabolic variational inequality arising from the valuation of strike reset options

    Science.gov (United States)

    Yang, Zhou; Yi, Fahuai; Dai, Min

    A strike reset option is an option that allows its holder to reset the strike price to the prevailing underlying asset price at a moment chosen by the holder. The pricing model of the option can be formulated as a one-dimensional parabolic variational inequality, or equivalently, a free boundary problem, where the free boundary just corresponds to the optimal reset strategy adopted by the holder of the option. This paper is concerned with the theoretical analysis of the model. The existence and uniqueness of the solution are established. Furthermore, we study properties of the free boundary. The monotonicity and C smoothness of the free boundary are proven in some situations.

  13. A novel complex air supply model for indoor air quality control via the occupant micro-environment demand ventilation

    International Nuclear Information System (INIS)

    Yang, Jie; Zhou, Bo; Jin, Maozhu; Wang, Jun; Xiong, Feng

    2016-01-01

    Protection of indoor air quality and human health can be achieved via ventilation, which has becomes one of the most important tasks for sustainable buildings. This approach also requires highly efficient and energy saving methods for modern building ventilations consisting of a set of parameters of the complex indoor system. Therefore, the advancement in understanding the characteristics of various ventilation methods is highly necessary. This study presents one novel air supply model for the complex occupant micro-environment demand control ventilations, to analyze the efficiency of various ventilation types. This model is established primarily according to the momentum and mass conservations, and goal of occupant micro-environment demand, which is a complex system with the characteristics of diversity and dynamic variation. As for different occupant densities, characteristics of outdoor air supply for controlling gaseous pollutant and three basic features of outdoor airflow supply reaching occupant micro-environment were obtained. This research shows that for various types of occupant density and storey height, the rising and descending rates of the demand outdoor airflow in mixing ventilation are higher than those under displacement ventilation conditions. In addition, since the structure is better designed and sewage flow is more efficient, the mixing ventilation also requires a much higher peak demand outdoor airflow than its counterpart. The increase of storey height will lead to a decline of pollutants in the breathing zone and the demand outdoor airflow. Fluctuations of air flow diffusion caused by the change of occupant density in architectural space, will lead to variations of outdoor airflow reaching occupant micro-environment. Accordingly, it would lead to the different peak values of demand outdoor airflow, and the difference becomes even significant if the occupant density increases. The variations of the air supply and fraction of air reaching the

  14. Can glacial shearing of sediment reset the signal used for luminescence dating?

    Science.gov (United States)

    Bateman, Mark D.; Swift, Darrel A.; Piotrowski, Jan A.; Rhodes, Edward J.; Damsgaard, Anders

    2018-04-01

    Understanding the geomorphology left by waxing and waning of former glaciers and ice sheets during the late Quaternary has been the focus of much research. This has been hampered by the difficulty in dating such features. Luminescence has the potential to be applied to glacial sediments but requires signal resetting prior to burial in order to provide accurate ages. This paper explores the possibility that, rather than relying on light to reset the luminescence signal, glacial processes underneath ice might cause resetting. Experiments were conducted on a ring-shear machine set up to replicate subglacial conditions and simulate the shearing that can occur within subglacial sediments. Luminescence measurement at the single grain level indicates that a number (albeit small) of zero-dosed grains were produced and that these increased in abundance with distance travelled within the shearing zone. Observed changes in grain shape characteristics with increasing shear distance indicate the presence of localised high pressure grain-to-grain stresses caused by grain bridges. This appears to explain why some grains became zeroed whilst others retained their palaeodose. Based on the observed experimental trend, it is thought that localised grain stress is a viable luminescence resetting mechanism. As such relatively short shearing distances might be sufficient to reset a small proportion of the luminescence signal within subglacial sediments. Dating of previously avoided subglacial sediments may therefore be possible.

  15. Augmented brain function by coordinated reset stimulation with slowly varying sequences

    OpenAIRE

    Magteld eZeitler; Peter A. Tass; Peter A. Tass; Peter A. Tass

    2015-01-01

    Several brain disorders are characterized by abnormally strong neuronal synchrony. Coordinated Reset (CR) stimulation was developed to selectively counteract abnormal neuronal synchrony by desynchronization. For this, phase resetting stimuli are delivered to different subpopulations in a timely coordinated way. In neural networks with spike timing-dependent plasticity CR stimulation may eventually lead to an anti-kindling, i.e. an unlearning of abnormal synaptic connectivity and abnormal sync...

  16. Augmented brain function by coordinated reset stimulation with slowly varying sequences

    OpenAIRE

    Zeitler, Magteld; Tass, Peter A.

    2015-01-01

    Several brain disorders are characterized by abnormally strong neuronal synchrony. Coordinated Reset (CR) stimulation was developed to selectively counteract abnormal neuronal synchrony by desynchronization. For this, phase resetting stimuli are delivered to different subpopulations in a timely coordinated way. In neural networks with spike timing-dependent plasticity CR stimulation may eventually lead to an anti-kindling, i.e., an unlearning of abnormal synaptic connectivity and abnormal syn...

  17. Set–Reset latch logical operation induced by colored noise

    International Nuclear Information System (INIS)

    Wang, Nan; Song, Aiguo

    2014-01-01

    We examine the possibility of obtaining Set–Reset latch logical operation in a symmetric bistable system subjected to OU noise. Three major results are presented. First, we prove the Set–Reset latch logical operation can be obtained driven by OU noise. Second, while increasing the correlation time, the optimal noise band shifts to higher level and becomes wider. Meanwhile, peak performance degrades from 100% accuracy, but the system can still perform reliable logical operation. Third, at fixed noise intensity, the success probability evolves non-monotonically as correlation time increases. The study might provide development of the new paradigm of memory device.

  18. Pressing reset on Moscow is worth a little Nato anxiety / Jonathan Steele

    Index Scriptorium Estoniae

    Steele, Jonathan

    2009-01-01

    USA president Barack Obama on avaldanud soovi vajutada USA-Vene suhetes reset-nuppu. Eesti president Toomas Hendrik Ilves ütles NATO tippkohtumise eelõhtul kuivalt, et arvutil reset-nuppu vajutades ei kustu mällu salvestatud failid siiski ära. President T. H. Ilvese teravast sõnavõtust president Lennart Meri konverentsi avamisel Tallinnas

  19. Assessing the completeness of optical resetting of quartz OSL in the natural environment

    International Nuclear Information System (INIS)

    Singarayer, J.S.; Bailey, R.M.; Ward, S.; Stokes, S.

    2005-01-01

    Resetting of previously accumulated optically stimulated luminescence (OSL) signals during transport of sediment is a fundamental requirement for reliable optical dating. The completeness of optical resetting of 46 modern-age quartz samples from a variety of depositional environments was examined. All equivalent dose (D e ) estimates were e from easy-to-bleach through to hard-to-bleach components. For all modern fluvial samples with non-zero D e values, SAR D e (t) analysis and component-resolved linearly modulated OSL (LM OSL) D e estimates showed this to be the case, implying incomplete resetting of previously accumulated charge. LM OSL measurements were also made to investigate the extent of bleaching of the slow components in the natural environment. In aeolian sediments examined, the natural LM OSL was effectively zero (i.e. all components were fully reset). The slow components of modern fluvial samples displayed measurable residual signals up to 15Gy

  20. Identification of partial resetting using De as a function of illumination time

    International Nuclear Information System (INIS)

    Bailey, R.M.; Singarayer, J.S.; Ward, S.; Stokes, S.

    2003-01-01

    Modern age samples from various depositional environments were examined for signal resetting. For 19 modern aeolian/beach samples all D e values obtained were e e values were e as a function of illumination (OSL measurement) time (D e (t)) plots were examined for all samples. Based on previous laboratory experiments, increases in D e (t) were expected for partially reset samples, and constant D e (t) for fully reset samples. All aeolian samples, both modern age and additional 'young' samples ( e (t) while all modern, non-zero D e , fluvial/colluvial samples showed increasing D e (t). 'Replacement plots', where a regenerated signal is substituted for the natural, yielded constant (flat) D e (t). These findings support strongly the use of D e (t) as a method of identifying incomplete resetting in fluvial samples. Potential complicating factors, such as illumination (bleaching) spectrum, thermal instability and component composition are discussed and a series of internal checks on the applicability of the D e (t) for each individual aliquot/grain level are outlined

  1. Effects of pay resets following drug use on attendance and hours worked in a therapeutic workplace.

    Science.gov (United States)

    Holtyn, August F; Silverman, Kenneth

    2016-06-01

    This secondary data analysis examined effects of an abstinence contingency on participation in a therapeutic workplace. Participants exposed to a pay reset after drug use did not differ in overall attendance from participants who were not exposed to a pay reset after drug use; however, they initially worked less after a pay reset than participants who did not receive a pay reset, and their attendance increased as their pay increased. Overall participation was not influenced by the abstinence contingency, but transient decreases in attendance occurred. © 2016 Society for the Experimental Analysis of Behavior.

  2. Air Force Supply Management Analysis of Activity Groups Financial Reports, Prices, and Cash Management

    National Research Council Canada - National Science Library

    1998-01-01

    The Air Force supply management activity group provides about two million types of inventory items, including weapon system spare parts, fuels, and medical-dental supplies, to customers which consist...

  3. 42 CFR 84.157 - Airflow resistance test; Type C supplied-air respirator, pressure-demand class; minimum...

    Science.gov (United States)

    2010-10-01

    ... test; Type C supplied-air respirator, pressure-demand class; minimum requirements. (a) The static... 42 Public Health 1 2010-10-01 2010-10-01 false Airflow resistance test; Type C supplied-air respirator, pressure-demand class; minimum requirements. 84.157 Section 84.157 Public Health PUBLIC HEALTH...

  4. 42 CFR 84.156 - Airflow resistance test; Type C supplied-air respirator, demand class; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... C supplied-air respirator, demand class; minimum requirements. (a) Inhalation resistance shall not... 42 Public Health 1 2010-10-01 2010-10-01 false Airflow resistance test; Type C supplied-air respirator, demand class; minimum requirements. 84.156 Section 84.156 Public Health PUBLIC HEALTH SERVICE...

  5. Shape memory alloy resetable spring lift for pedestrian protection

    Science.gov (United States)

    Barnes, Brian M.; Brei, Diann E.; Luntz, Jonathan E.; Strom, Kenneth; Browne, Alan L.; Johnson, Nancy

    2008-03-01

    Pedestrian protection has become an increasingly important aspect of automotive safety with new regulations taking effect around the world. Because it is increasingly difficult to meet these new regulations with traditional passive approaches, active lifts are being explored that increase the "crush zone" between the hood and rigid under-hood components as a means of mitigating the consequences of an impact with a non-occupant. Active lifts, however, are technically challenging because of the simultaneously high forces, stroke and quick timing resulting in most of the current devices being single use. This paper introduces the SMArt (Shape Memory Alloy ReseTable) Spring Lift, an automatically resetable and fully reusable device, which couples conventional standard compression springs to store the energy required for a hood lift, with Shape Memory Alloys actuators to achieve both an ultra high speed release of the spring and automatic reset of the system for multiple uses. Each of the four SMArt Device subsystems, lift, release, lower and reset/dissipate, are individually described. Two identical complete prototypes were fabricated and mounted at the rear corners of the hood, incorporated within a full-scale vehicle testbed at the SMARTT (Smart Material Advanced Research and Technology Transfer) lab at University of Michigan. Full operational cycle testing of a stationary vehicle in a laboratory setting confirms the ultrafast latch release, controlled lift profile, gravity lower to reposition the hood, and spring recompression via the ratchet engine successfully rearming the device for repeat cycles. While this is only a laboratory demonstration and extensive testing and development would be required for transition to a fielded product, this study does indicate that the SMArt Lift has promise as an alternative approach to pedestrian protection.

  6. GHK and DNA: Resetting the Human Genome to Health

    Directory of Open Access Journals (Sweden)

    Loren Pickart

    2014-01-01

    Full Text Available During human aging there is an increase in the activity of inflammatory, cancer promoting, and tissue destructive genes plus a decrease in the activity of regenerative and reparative genes. The human blood tripeptide GHK possesses many positive effects but declines with age. It improves wound healing and tissue regeneration (skin, hair follicles, stomach and intestinal linings, and boney tissue, increases collagen and glycosaminoglycans, stimulates synthesis of decorin, increases angiogenesis, and nerve outgrowth, possesses antioxidant and anti-inflammatory effects, and increases cellular stemness and the secretion of trophic factors by mesenchymal stem cells. Recently, GHK has been found to reset genes of diseased cells from patients with cancer or COPD to a more healthy state. Cancer cells reset their programmed cell death system while COPD patients’ cells shut down tissue destructive genes and stimulate repair and remodeling activities. In this paper, we discuss GHK’s effect on genes that suppress fibrinogen synthesis, the insulin/insulin-like system, and cancer growth plus activation of genes that increase the ubiquitin-proteasome system, DNA repair, antioxidant systems, and healing by the TGF beta superfamily. A variety of methods and dosages to effectively use GHK to reset genes to a healthier state are also discussed.

  7. Improved airline-type supplied-air plastic suit

    International Nuclear Information System (INIS)

    Jolley, L. Jr.; Zippler, D.B.; Cofer, C.H.; Harper, J.A.

    1978-06-01

    Two piece supplied-air plastic suits are used extensively at the Savannah River Plant for personnel protection against inhalation of airborne plutonium and tritium. Worker comfort and noise level problems gave impetus to development of an improved suit and aid distribution system. The resulting plastic suit and development work are discussed. The plastic suit unit cost is less than $20, the hearing zone noise level is less than 75 dBA, protection factors exceed 10,000, and user comfort is approved. This suit is expected to meet performance requirements for unrestricted use

  8. Routes to Chaos Induced by a Discontinuous Resetting Process in a Hybrid Spiking Neuron Model.

    Science.gov (United States)

    Nobukawa, Sou; Nishimura, Haruhiko; Yamanishi, Teruya

    2018-01-10

    Several hybrid spiking neuron models combining continuous spike generation mechanisms and discontinuous resetting processes following spiking have been proposed. The Izhikevich neuron model, for example, can reproduce many spiking patterns. This model clearly possesses various types of bifurcations and routes to chaos under the effect of a state-dependent jump in the resetting process. In this study, we focus further on the relation between chaotic behaviour and the state-dependent jump, approaching the subject by comparing spiking neuron model versions with and without the resetting process. We first adopt a continuous two-dimensional spiking neuron model in which the orbit in the spiking state does not exhibit divergent behaviour. We then insert the resetting process into the model. An evaluation using the Lyapunov exponent with a saltation matrix and a characteristic multiplier of the Poincar'e map reveals that two types of chaotic behaviour (i.e. bursting chaotic spikes and near-period-two chaotic spikes) are induced by the resetting process. In addition, we confirm that this chaotic bursting state is generated from the periodic spiking state because of the slow- and fast-scale dynamics that arise when jumping to the hyperpolarization and depolarization regions, respectively.

  9. Low-temperature baseboard heaters with integrated air supply - An analytical and numerical investigation

    Energy Technology Data Exchange (ETDEWEB)

    Ploskic, Adnan; Holmberg, Sture [Fluid and Climate Technology, School of Architecture and Built Environment, KTH, Marinens vaeg 30, SE-13640 Handen, Stockholm (Sweden)

    2011-01-15

    The functioning of a hydronic baseboard heating system with integrated air supply was analyzed. The aim was to investigate thermal performance of the system when cold outdoor (ventilation) airflow was forced through the baseboard heater. The performance of the system was evaluated for different ventilation rates at typical outdoor temperatures during the Swedish winter season. Three different analytical models and Computational Fluid Dynamics (CFD) were used to predict the temperature rise of the airflow inside the baseboard heater. Good agreement between numerical (CFD) and analytical calculations was obtained. Calculations showed that it was fully possible to pre-heat the incoming airflow to the indoor temperature and to cover transmission losses, using 45 C supply water flow. The analytical calculations also showed that the airflow per supply opening in the baseboard heater needed to be limited to 7.0 l/s due to pressure losses inside the channel. At this ventilation rate, the integrated system with one air supply gave about 2.1 more heat output than a conventional baseboard heating system. CFD simulations also showed that the integrated system was capable of countering downdraught created by 2.0 m high glazed areas and a cold outdoor environment. Draught discomfort in the case with the conventional system was slightly above the recommended upper limit, but heat distribution across whole analyzed office space was uniform for both heating systems. It was concluded that low-temperature baseboard heating systems with integrated air supply can meet both international comfort requirements, and lead to energy savings in cold climates. (author)

  10. Effect of supply air temperature on air distribution in a room with radiant heating and mechanical ventilation

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Zhao, Jianing; Fang, Lei

    2017-01-01

    and the horizontal distribution of containment concentration in the breathing zone were measured as the supply air temperature ranged from 15.0°C (59°F)to 19.0°C (66.2°F). The results showed that the vertical air temperature differences were less than 0.3°C (32.5°F) with FH+MV or CH+MV and between 1.9°C (35.4°F...

  11. Use of perforated acoustic panels as supply air diffusers in diffuse ceiling ventilation systems

    DEFF Research Database (Denmark)

    Iqbal, Ahsan; Kazemi, Seyed Hossein; Ardkapan, Siamak Rahimi

    Ventilation is needed for diluting and removing the contaminants, odour and excess heat from the building interior. It is important that the inhabitants perceive the ventilated spaces as comfortable. Therefore, the supply air should reach all parts of the occupied zones. Troldtekt has been...... manufacturing perforated acoustic panels for the last 13 years. The panels can be used not only in applications related to acoustics but also as low pressure drop supply air diffusers, particularly in diffuse ceiling ventilation systems. The present study verifies on a theoretically level the performance...

  12. Core reset system design for linear induction accelerator

    International Nuclear Information System (INIS)

    Durga Praveen Kumar, D.; Mitra, S.; Sharma, Archana; Nagesh, K.V.; Chakravarthy, D.P.

    2006-01-01

    A repetitive pulsed power system based Linear Induction Accelerator (LIA-200) is being developed at BARC to get an electron beam of 200keV, 5kA, 50ns, 10-100 Hz. Amorphous core is the heart of these accelerators. It serves various functions in different subsystems viz. pulse power modulator, pulse transformer, magnetic switches and induction cavities. One of the factors that make the magnetic components compact is utilization of the total flux swing available in the core. In the present system, magnetic switches, pulse transformers, and induction cavity are designed to avail the full flux swing available in the core. For achieving this objective, flux density in the core has to be kept at the reverse saturation, before the main pulse is applied. The electrical circuit which makes it possible is called the core reset system. In this paper the details of core reset system designed for LIA-200 are described. (author)

  13. Call-centre occupant response to new and used filters at two outdoor air supply rates

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Wyon, David; Nielsen, J.

    2002-01-01

    A 2x2 replicaterd field intervention experiment was conducted in a call-centre providing a public telephone directory service: outdoor air supply rate was 8% or 80% of the total airflow of 430 L/s providing 3.5 h-1; and the supply air filters were either new or used (i.e. used in place for 6 mont......). Each of these 4 conditions was maintained for a full working week at a time. Room temperature and humidity averaged 24 deg.C and 27% RH. The 26 operators were blind to conditions and assessed perceived air quality (PAQ), the intensity of Sick Building Syndrome (SBS) symnptoms and self...

  14. Study on the influence of supplying compressed air channels and evicting channels on pneumatical oscillation systems for vibromooshing

    Science.gov (United States)

    Glăvan, D. O.; Radu, I.; Babanatsas, T.; Babanatis Merce, R. M.; Kiss, I.; Gaspar, M. C.

    2018-01-01

    The paper presents a pneumatic system with two oscillating masses. The system is composed of a cylinder (framework) with mass m1, which has a piston with mass m2 inside. The cylinder (framework system) has one supplying channel for compressed air and one evicting channel for each work chamber (left and right of the piston). Functionality of the piston position comparatively with the cylinder (framework) is possible through the supplying or evicting of compressed air. The variable force that keeps the movement depends on variation of the pressure that is changing depending on the piston position according to the cylinder (framework) and to the section form that is supplying and evicting channels with compressed air. The paper presents the physical model/pattern, the mathematical model/pattern (differential equations) and numerical solution of the differential equations in hypothesis with the section form of supplying and evicting channels with compressed air is rectangular (variation linear) or circular (variation nonlinear).

  15. Re-Setting Music Education's "Default Settings"

    Science.gov (United States)

    Regelski, Thomas A.

    2013-01-01

    This paper explores the effects and problems of one highly influential default setting of the "normal style template" of music education and proposes some alternatives. These do not require abandoning all traditional templates for school music. But re-setting the default settings does depend on reconsidering the promised function of…

  16. Resonator reset in circuit QED by optimal control for large open quantum systems

    Science.gov (United States)

    Boutin, Samuel; Andersen, Christian Kraglund; Venkatraman, Jayameenakshi; Ferris, Andrew J.; Blais, Alexandre

    2017-10-01

    We study an implementation of the open GRAPE (gradient ascent pulse engineering) algorithm well suited for large open quantum systems. While typical implementations of optimal control algorithms for open quantum systems rely on explicit matrix exponential calculations, our implementation avoids these operations, leading to a polynomial speedup of the open GRAPE algorithm in cases of interest. This speedup, as well as the reduced memory requirements of our implementation, are illustrated by comparison to a standard implementation of open GRAPE. As a practical example, we apply this open-system optimization method to active reset of a readout resonator in circuit QED. In this problem, the shape of a microwave pulse is optimized such as to empty the cavity from measurement photons as fast as possible. Using our open GRAPE implementation, we obtain pulse shapes, leading to a reset time over 4 times faster than passive reset.

  17. UVA-induced reset of hydroxyl radical ultradian rhythm improves temporal lipid production in Chlorella vulgaris.

    Science.gov (United States)

    Balan, Ranjini; Suraishkumar, G K

    2014-01-01

    We report for the first time that the endogenous, pseudo-steady-state, specific intracellular levels of the hydroxyl radical (si-OH) oscillate in an ultradian fashion (model system: the microalga, Chlorella vulgaris), and also characterize the various rhythm parameters. The ultradian rhythm in the endogenous levels of the si-OH occurred with an approximately 6 h period in the daily cycle of light and darkness. Further, we expected that the rhythm reset to a shorter period could rapidly switch the cellular redox states that could favor lipid accumulation. We reset the endogenous rhythm through entrainment with UVA radiation, and generated two new ultradian rhythms with periods of approximately 2.97 h and 3.8 h in the light phase and dark phase, respectively. The reset increased the window of maximum lipid accumulation from 6 h to 12 h concomitant with the onset of the ultradian rhythms. Further, the saturated fatty acid content increased approximately to 80% of total lipid content, corresponding to the peak maxima of the hydroxyl radical levels in the reset rhythm. © 2014 American Institute of Chemical Engineers.

  18. EEG phase reset due to auditory attention: an inverse time-scale approach

    International Nuclear Information System (INIS)

    Low, Yin Fen; Strauss, Daniel J

    2009-01-01

    We propose a novel tool to evaluate the electroencephalograph (EEG) phase reset due to auditory attention by utilizing an inverse analysis of the instantaneous phase for the first time. EEGs were acquired through auditory attention experiments with a maximum entropy stimulation paradigm. We examined single sweeps of auditory late response (ALR) with the complex continuous wavelet transform. The phase in the frequency band that is associated with auditory attention (6–10 Hz, termed as theta–alpha border) was reset to the mean phase of the averaged EEGs. The inverse transform was applied to reconstruct the phase-modified signal. We found significant enhancement of the N100 wave in the reconstructed signal. Analysis of the phase noise shows the effects of phase jittering on the generation of the N100 wave implying that a preferred phase is necessary to generate the event-related potential (ERP). Power spectrum analysis shows a remarkable increase of evoked power but little change of total power after stabilizing the phase of EEGs. Furthermore, by resetting the phase only at the theta border of no attention data to the mean phase of attention data yields a result that resembles attention data. These results show strong connections between EEGs and ERP, in particular, we suggest that the presentation of an auditory stimulus triggers the phase reset process at the theta–alpha border which leads to the emergence of the N100 wave. It is concluded that our study reinforces other studies on the importance of the EEG in ERP genesis

  19. EEG phase reset due to auditory attention: an inverse time-scale approach.

    Science.gov (United States)

    Low, Yin Fen; Strauss, Daniel J

    2009-08-01

    We propose a novel tool to evaluate the electroencephalograph (EEG) phase reset due to auditory attention by utilizing an inverse analysis of the instantaneous phase for the first time. EEGs were acquired through auditory attention experiments with a maximum entropy stimulation paradigm. We examined single sweeps of auditory late response (ALR) with the complex continuous wavelet transform. The phase in the frequency band that is associated with auditory attention (6-10 Hz, termed as theta-alpha border) was reset to the mean phase of the averaged EEGs. The inverse transform was applied to reconstruct the phase-modified signal. We found significant enhancement of the N100 wave in the reconstructed signal. Analysis of the phase noise shows the effects of phase jittering on the generation of the N100 wave implying that a preferred phase is necessary to generate the event-related potential (ERP). Power spectrum analysis shows a remarkable increase of evoked power but little change of total power after stabilizing the phase of EEGs. Furthermore, by resetting the phase only at the theta border of no attention data to the mean phase of attention data yields a result that resembles attention data. These results show strong connections between EEGs and ERP, in particular, we suggest that the presentation of an auditory stimulus triggers the phase reset process at the theta-alpha border which leads to the emergence of the N100 wave. It is concluded that our study reinforces other studies on the importance of the EEG in ERP genesis.

  20. Investigating the impact of noise incidence angle on the sound insulation of a supply air window

    DEFF Research Database (Denmark)

    Hansen, Morten B.; Tambo, Torben

    2015-01-01

    for the highest frequencies are less than the sound insulation of the same window measured in the laboratory. The aim of this paper is through simulations in the geometric acoustic simulation software ODEON, to investigate the impact of noise incidence angle on the sound insulation of the Supply Air Window......The Danish Environmental Agency introduced in 2007 a guideline “Noise from roads”, in which noise limits for open windows were introduced. This guideline has led to investigations of open windows with good sound insulation, and among one of these windows are the “Supply Air Window”. Prior sound...... insulation measurements of the Supply Air Window show a difference in the frequency range above 2 kHz, for field measurements carried out according to EN ISO 140-5 and laboratory measurements carried out according to EN ISO 10140-2. It is found that the sound insulation measured in the field setup...

  1. Air intake device for at least one stand-by aggregate installed in an emergency power supply building

    International Nuclear Information System (INIS)

    Stoll, A.; Schilling, R.

    1980-01-01

    Stand-by aggregates are installed in an energency power supply building in order to ensure the cooling of nuclear power plants during accidents. In order to assure the stand-by aggregates to be supplied with combustion air also in the case of fire, each stand-by aggregate is provided with two intake pipes for the combustion air, which are horizontally lead through the building wall on the opposite sides of the energency power supply building. Fire valves are incorporated in the inlet pipes, and one of them will always close in the case of fire. (orig.) [de

  2. Circadian phase resetting via single and multiple control targets.

    Directory of Open Access Journals (Sweden)

    Neda Bagheri

    2008-07-01

    Full Text Available Circadian entrainment is necessary for rhythmic physiological functions to be appropriately timed over the 24-hour day. Disruption of circadian rhythms has been associated with sleep and neuro-behavioral impairments as well as cancer. To date, light is widely accepted to be the most powerful circadian synchronizer, motivating its use as a key control input for phase resetting. Through sensitivity analysis, we identify additional control targets whose individual and simultaneous manipulation (via a model predictive control algorithm out-perform the open-loop light-based phase recovery dynamics by nearly 3-fold. We further demonstrate the robustness of phase resetting by synchronizing short- and long-period mutant phenotypes to the 24-hour environment; the control algorithm is robust in the presence of model mismatch. These studies prove the efficacy and immediate application of model predictive control in experimental studies and medicine. In particular, maintaining proper circadian regulation may significantly decrease the chance of acquiring chronic illness.

  3. Energy and air emission effects of water supply.

    Science.gov (United States)

    Stokes, Jennifer R; Horvath, Arpad

    2009-04-15

    Life-cycle air emission effects of supplying water are explored using a hybrid life-cycle assessment For the typically sized U.S. utility analyzed, recycled water is preferable to desalination and comparable to importation. Seawater desalination has an energy and air emission footprint that is 1.5-2.4 times larger than that of imported water. However, some desalination modes fare better; brackish groundwater is 53-66% as environmentally intensive as seawater desalination. The annual water needs (326 m3) of a typical Californian that is met with imported water requires 5.8 GJ of energy and creates 360 kg of CO2 equivalent emissions. With seawater desalination, energy use would increase to 14 GJ and 800 kg of CO2 equivalent emissions. Meeting the water demand of California with desalination would consume 52% of the state's electricity. Supply options were reassessed using alternative electricity mixes, including the average mix of the United States and several renewable sources. Desalination using solar thermal energy has lower greenhouse gas emissions than that of imported and recycled water (using California's electricity mix), but using the U.S. mix increases the environmental footprint by 1.5 times. A comparison with a more energy-intensive international scenario shows that CO2 equivalent emissions for desalination in Dubai are 1.6 times larger than in California. The methods, decision support tool (WEST), and results of this study should persuade decision makers to make informed water policy choices by including energy consumption and material use effects in the decision-making process.

  4. An experimental study on defrosting heat supplies and energy consumptions during a reverse cycle defrost operation for an air source heat pump

    International Nuclear Information System (INIS)

    Dong Jiankai; Deng Shiming; Jiang Yiqiang; Xia Liang; Yao Yang

    2012-01-01

    For a space heating air source heat pump (ASHP) unit, when its outdoor coil surface temperature is below both the air dew point temperature and the freezing point of water, frost will form on its outdoor coil surface. Frosting affects its operational performance and energy efficiency. Therefore, periodic defrosting is necessary. Currently, the most widely used standard defrosting method for ASHP units is reverse cycle defrost. The energy that should have been used for space heating is used to melt frost, vaporize the melted frost off outdoor coil surface and heat ambient air during defrosting. It is therefore necessary to study the sources of heat supplies and the end-uses of the heat supplied during a reverse cycle defrost operation. In this paper, firstly, an experimental setup is described and experimental procedures are detailed. This is followed by reporting the experimental results and the evaluation of defrosting efficiency for the experimental ASHP unit. Finally, an evaluation of defrosting heat supplies and energy consumptions during a revere cycle defrost operation for the experimental ASHP unit is presented. The experimental and evaluation results indicated that the heat supply from indoor air contributed to 71.8% of the total heat supplied for defrosting and 59.4% of the supplied energy was used for melting frost. The maximum defrosting efficiency could be up to 60.1%. - Highlights: ► Heat supply and consumption during reverse cycle defrost was experimentally studied. ► Indoor air contributed to >70% of total heat supply when indoor fan was turned on. ► ∼60% of the supplied energy was used for melting frost. ► Alternate heat supply other than indoor air should be explored.

  5. The effect of air supply on nitrogen removal using a biological filter ...

    African Journals Online (AJOL)

    2009-10-02

    Oct 2, 2009 ... 0.04 m3∙m−2∙d−1) (Fig. 2). Air was supplied by means of a compressor (Model: Fini, ... effluent from a domestic wastewater treatment plant (COD was approx. .... The resultant ammonium was determined as men- tioned before ...

  6. Impaired theta phase-resetting underlying auditory N1 suppression in chronic alcoholism.

    Science.gov (United States)

    Fuentemilla, Lluis; Marco-Pallarés, Josep; Gual, Antoni; Escera, Carles; Polo, Maria Dolores; Grau, Carles

    2009-02-18

    It has been suggested that chronic alcoholism may lead to altered neural mechanisms related to inhibitory processes. Here, we studied auditory N1 suppression phenomena (i.e. amplitude reduction with repetitive stimuli) in chronic alcoholic patients as an early-stage information-processing brain function involving inhibition by the analysis of the N1 event-related potential and time-frequency computation (spectral power and phase-resetting). Our results showed enhanced neural theta oscillatory phase-resetting underlying N1 generation in suppressed N1 event-related potential. The present findings suggest that chronic alcoholism alters neural oscillatory synchrony dynamics at very early stages of information processing.

  7. Experimental study on two-stage air supply downdraft gasifier and dual fuel engine system

    Energy Technology Data Exchange (ETDEWEB)

    Nhuchhen, Daya Ram; Salam, P.A. [Asian Institute of Technology, Energy Field of Study, School of Environment Resource and Development, P. O. Box 4, Klong Luang, Pathumthani (Thailand)

    2012-06-15

    Biomass is a widely used renewable energy resource with net balanced carbon dioxide absorptions and emissions. An inefficient use of solid biomass in combustion process emits more gaseous pollutants, increasing the pollution level. Biomass gasification is one of the techniques to support efficient use of biomass. Multistage gasification is a method of gasification to improve quality of the producer gas in which two separate reactors are designed for separating gasification reactions. This study presents experimental results of gasification using Eucalyptus wood in a single long cylindrical reactor with two air supply ports, i.e., primary and secondary. The effect of different air supply rates on the heating values of the producer gas was studied. Optimum primary and secondary air supply rate of 100 and 80 l/min at equivalence ratio of 0.38 was observed with producer gas lower heating value of 4.72 MJ Nm{sup -3}. The performance of a diesel engine in the dual fuel mode was also evaluated. The overall gasifier engine system efficiency was 13.86 % at an electrical load of 10.54 kW{sub e} with specific energy consumption of 16.22 MJ kWh{sup -1}. The heat recovery system was designed and tested to recover heat from producer gas in the form of hot water. (orig.)

  8. Rapid resetting of human peripheral clocks by phototherapy during simulated night shift work.

    Science.gov (United States)

    Cuesta, Marc; Boudreau, Philippe; Cermakian, Nicolas; Boivin, Diane B

    2017-11-24

    A majority of night shift workers have their circadian rhythms misaligned to their atypical schedule. While bright light exposure at night is known to reset the human central circadian clock, the behavior of peripheral clocks under conditions of shift work is more elusive. The aim of the present study was to quantify the resetting effects of bright light exposure on both central (plasma cortisol and melatonin) and peripheral clocks markers (clock gene expression in peripheral blood mononuclear cells, PBMCs) in subjects living at night. Eighteen healthy subjects were enrolled to either a control (dim light) or a bright light group. Blood was sampled at baseline and on the 4 th day of simulated night shift. In response to a night-oriented schedule, the phase of PER1 and BMAL1 rhythms in PBMCs was delayed by ~2.5-3 h (P shift was observed for the other clock genes and the central markers. Three cycles of 8-h bright light induced significant phase delays (P night-oriented schedule and a rapid resetting effect of nocturnal bright light exposure on peripheral clocks.

  9. Inspiring students through an authentic polar science expedition: the RESEt Project

    Science.gov (United States)

    Cattadori, Matteo

    2016-04-01

    RESEt (Research and Education Svalbard Experience www.resetsvalbard.it) is an ongoing educational project focusing mainly on polar and climate system topics. It started in 2014 and will end in 2017 with the high school diploma of the 22 students (16 y. o.) making the participant class. This class attend a school (Liceo Filzi, Rovereto, Trento. Italy) with a primary focus on disciplines like philosophy and education, rather then STEM (Science, Technology, Engineering, and Mathematics). Nevertheless their science curricula include climate topics that are rather challenging to grasp and, at the same time, crucial for their scientific citizenship. Some questions arise: How to foster their interest in geosciences topics? How to engage them in authentic scientific knowledge? How to increase their interest in scientific university courses during their post-secondary career? RESEt project will attempt to answer these questions through the development of integrated activities distributed over the last three years of their high school cycle. The most important moment will be an educational scientific expedition at the Svalbard, an archipelago located in the Arctic. The expedition be entirely organized, planned, and directed by students. In Svalbard, students will visit the main scientific facilities devoted to climate studies including those of Italian CNR (National Research Council) and they will perform some environmental measurement using data-loggers. Students are even involved in the fundraising process to raise more than ten thousand Euros needed to for travel expenses. This work is aimed mainly at presenting some of the preliminary data collected during the RESEt project, including the fundraising aspects. The management of the RESEt project strongly relies on the experience and network gained by the abstract author during the participation to the Education and Public Outreach (EPO) program of International Polar Year (IPY) 2007-2009 as well as the support of Polar

  10. Transient resetting: a novel mechanism for synchrony and its biological examples.

    Directory of Open Access Journals (Sweden)

    Chunguang Li

    2006-08-01

    Full Text Available The study of synchronization in biological systems is essential for the understanding of the rhythmic phenomena of living organisms at both molecular and cellular levels. In this paper, by using simple dynamical systems theory, we present a novel mechanism, named transient resetting, for the synchronization of uncoupled biological oscillators with stimuli. This mechanism not only can unify and extend many existing results on (deterministic and stochastic stimulus-induced synchrony, but also may actually play an important role in biological rhythms. We argue that transient resetting is a possible mechanism for the synchronization in many biological organisms, which might also be further used in the medical therapy of rhythmic disorders. Examples of the synchronization of neural and circadian oscillators as well as a chaotic neuron model are presented to verify our hypothesis.

  11. The scope of inducing natural air supply via the façade

    NARCIS (Netherlands)

    van den Engel, P.J.W.; Kurvers, S.R.

    2017-01-01

    An overview is given of recent developments in the use of a system of inducing natural air supply via the façade in the Netherlands. This is followed by a review of the results of measurements from climate chamber experiments of its inducing ventilation performance and detailed insights gained

  12. Seismic assessment of air-cooled type emergency electric power supply system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-15

    JNES initiated seismic assessment programs to develop seismic review criterions for the air-cooled system (diesel generator, gas turbine generator), which will be newly installed for enhancing the diversity of emergency electric power supply system. Five principal subjects are involved in the programs: two subjects for fiscal 2011 and three ones for fiscal 2012 and 2013. The summary of outcomes is as follows: 1) Past capacity test data and related technical issues (2011). Seismic capacity data obtained from past seismic shaking tests were investigated. 2) Test programs based on the investigation of system specification (2011). Design specifications for the air-cooled system were investigated. 3) Large Air Fin Cooler (AFC) one unit model seismic capacity test and quantitative seismic capacity evaluation. AFC one unit model seismic capacity tests were conducted and quantitative seismic capacities were evaluated. (author)

  13. Seismic assessment of air-cooled type emergency electric power supply system

    International Nuclear Information System (INIS)

    2013-01-01

    JNES initiated seismic assessment programs to develop seismic review criterions for the air-cooled system (diesel generator, gas turbine generator), which will be newly installed for enhancing the diversity of emergency electric power supply system. Five principal subjects are involved in the programs: two subjects for fiscal 2011 and three ones for fiscal 2012 and 2013. The summary of outcomes is as follows: 1) Past capacity test data and related technical issues (2011). Seismic capacity data obtained from past seismic shaking tests were investigated. 2) Test programs based on the investigation of system specification (2011). Design specifications for the air-cooled system were investigated. 3) Large Air Fin Cooler (AFC) one unit model seismic capacity test and quantitative seismic capacity evaluation. AFC one unit model seismic capacity tests were conducted and quantitative seismic capacities were evaluated. (author)

  14. Detection efficiency characteristics of free-running InGaAs/InP single photon detector using passive quenching active reset IC

    International Nuclear Information System (INIS)

    Zheng Fu; Wang Chao; Sun Zhi-Bin; Zhai Guang-Jie

    2016-01-01

    InGaAs/InP avalanche photodiodes (APD) are rarely used in a free-running regime for near-infrared single photon detection. In order to overcome the detrimental afterpulsing, we demonstrate a passive quenching active reset integrated circuit. Taking advantage of the inherent fast passive quenching process and active reset to reduce reset time, the integrated circuit is useful for reducing afterpulses and is also area-efficient. We investigate the free-running single photon detector’s afterpulsing effect, de-trapping time, dark count rate, and photon detection efficiency, and also compare with gated regime operation. After correction for deadtime and afterpulse, we find that the passive quenching active reset free-running single photon detector’s performance is consistent with gated operation. (paper)

  15. Performance of Chilled Beam with Radial Swirl Jet and Diffuse Ceiling Air Supply in Heating Mode

    DEFF Research Database (Denmark)

    Bertheussen, Bård; Mustakallio, Panu; Melikov, Arsen Krikor

    2013-01-01

    ). The room air temperature was kept at 21 °C. Tracer gas was used to simulate pollution from floor and desk. The experimental conditions comprised: 1) night time without heat sources in the room; the room air conditioning system was used to heat up the room; 2) heat load generated by an occupant (simulated...... by dressed thermal manikin) and a laptop; 3) heating by convectors positioned under the window (convectors used alone and convector used together with CSW supplying isothermal air for ventilation). The heat distribution provided by the systems was not effective compare to the distribution provided......The performance of diffuse ceiling air supply and chilled beam with swirl jet (CSW) in heating mode (winter situation) was studied and compared with regard to the generated indoor environment. An office mock-up with one occupant was simulated in a test room (4.5 x 3.95 x 3.5 m3 (L x W x H...

  16. Accelerator magnet power supply using storage generator

    International Nuclear Information System (INIS)

    Karady, G.; Thiessen, H.A.

    1987-01-01

    Recently, a study investigated the feasibility of a large, 60 GeV accelerator. This paper presents the conceptual design of the magnet power supply (PS() and energy storage system. The main ring magnets are supplied by six, high-voltage and two, low-voltage power supplies. These power supplies drive a trapezoidal shaped current wave through the magnets. The peak current is 10 kA and the repetition frequency is 3.3 Hz. During the acceleration period the current is increased from 1040 A to 10,000 A within 50 msec which requires a loop voltage of 120 kV and a peak power of 1250 MW. During the reset period, the PS operates as an inverter with a peak power of -1250 MW. The large energy fluctuation necessitates the use of a storage generator. Because of the relatively high operation frequency, this generator operates in a transient mode which significantly increases the rotor current and losses. The storage generator is directly driven by a variable speed drive, which draws a practically constant power of 17 MW from the ac supply network and eliminates the pulse loading. For the reduction of dc ripple, the power supplies operate in a 24 pulse mode

  17. Morning and Evening Oscillators Cooperate to Reset Circadian Behavior in Response to Light Input

    Directory of Open Access Journals (Sweden)

    Pallavi Lamba

    2014-05-01

    Full Text Available Light is a crucial input for circadian clocks. In Drosophila, short light exposure can robustly shift the phase of circadian behavior. The model for this resetting posits that circadian photoreception is cell autonomous: CRYPTOCHROME senses light, binds to TIMELESS (TIM, and promotes its degradation, which is mediated by JETLAG (JET. However, it was recently proposed that interactions between circadian neurons are also required for phase resetting. We identify two groups of neurons critical for circadian photoreception: the morning (M and the evening (E oscillators. These neurons work synergistically to reset rhythmic behavior. JET promotes acute TIM degradation cell autonomously in M and E oscillators but also nonautonomously in E oscillators when expressed in M oscillators. Thus, upon light exposure, the M oscillators communicate with the E oscillators. Because the M oscillators drive circadian behavior, they must also receive inputs from the E oscillators. Hence, although photic TIM degradation is largely cell autonomous, neural cooperation between M and E oscillators is critical for circadian behavioral photoresponses.

  18. First and higher order, heuristically based generalized perturbation theory (HGPT) with optional control reset variable

    International Nuclear Information System (INIS)

    Gandini, A.

    1996-01-01

    The heuristically based generalized perturbation theory (HGPT), to first and higher order, applied to the neutron field of a reactor system, is discussed in relation to the criticality reset procedure. This procedure is implicit within the GPT methodology, corresponding to the so called filtering of the importance function relevant to the neutron field from the fundamental mode contamination. It is common practice to use the so called ''lambda''-mode filter. In order to account for any possible reset option, a general definition is introduced of an intensive control variable (ρ) entering into the governing equations, and correspondingly a fundamental ρ-mode filtering of the importance function is defined, relevant to the real criticality reset (control) mechanism adopted. A simple example illustrates the need to take into account the correct filtering, so as to avoid significant inaccuracies in the sensitivity calculation results. The extension of this filtering technique to other functions entering into the GPT perturbative formulations at first and higher order is also discussed. (author)

  19. Effects of ramp reset pulses on the address discharge in a shadow mask plasma display panel

    International Nuclear Information System (INIS)

    Yang Lanlan; Tu Yan; Zhang Xiong; Jiang Youyan; Zhang Jian; Wang Baoping

    2007-01-01

    A two-dimensional self-consistent numerical simulation model is used to analyse the effects of the ramp reset pulses on the address discharge in a shadow mask plasma display panel (SM-PDP). Some basic parameters such as the slope of the ramp pulse and the terminal voltage of the ramp reset period are varied to investigate their effects. The simulation results illustrate that the wall voltage is mainly decided by the terminal voltage and the firing voltage at the end of the ramp reset period. Moreover, the variation of the ramp slope will also bring a few modifications to the wall voltage. The priming particles in the beginning of the addressing period are related to the slope of the ramping down voltage pulse. The simulation results can help us optimize the driving scheme of the SM-PDP

  20. Evaluation of simplified ventilation system with direct air supply through the facade in a school in a cold climate

    Energy Technology Data Exchange (ETDEWEB)

    Mysen, M. [Norwegian Building Research Institute, Blindern, Oslo (Norway); Department of Energy and Process Technology, Norwegian University of Science and Technology (NTNU), Trondheim (Norway); Schild, P. G.; Hellstrand, V.; Thunshelle, K. [Norwegian Building Research Institute, Blindern, Oslo (Norway)

    2004-07-01

    Many educational buildings in industrialised countries have poor indoor climate, according to today's knowledge about the impact of indoor climate on well-being and productivity. Budget restrictions and practical limitations such as lack of space for central air handling units and ventilation ducts, have motivated the application of simplified ventilation systems in some schools, such as taking unconditioned supply air directly from the facade. One such school was recently evaluated in Norway. On cold days, thermal comfort in the classroom deteriorated due to cold down draught from the supply outlet. In addition, moist and fertile conditions for microbiological growth were observed in the air supply ductwork. On the other hand the same pupils are more satisfied with the school and have less sick building syndrome (SBS) symptoms during winter than summer. An improved control strategy with a temperature-compensated CO{sub 2} set-point for controlling the air flow is suggested. This could improve thermal comfort and reduce energy use without compromising perceived air quality (PAQ) during cold weather. Furthermore it could improve indoor air quality (IAQ) during warm weather with only a slight increase of energy use. Further evaluation of an improved solution is needed before such a ventilation concept can be recommended in cold climates. (author)

  1. Test procedure for calibration, grooming and alignment of the LDUA Purge Air Supply System

    International Nuclear Information System (INIS)

    Potter, J.D.

    1995-01-01

    The Light Duty Utility Arm (LDUA) is a remotely operated manipulator used to enter into underground waste tanks through one of the tank risers. National Electric Code requirements mandate that the in-tank portions of the LDUA be maintained at a positive pressure for entrance into a flammable atmosphere. The LDUA Purge Air Supply System (PASS) is a small, portable air compressor, which provides a constant low flow of instrument grade air for this purpose. This procedure is used to assure that the instrumentation and equipment comprising the PASS is properly adjusted in order to achieve its intended functions successfully

  2. Portland Energy Centre: Securing supply and clearing the air

    International Nuclear Information System (INIS)

    2003-02-01

    The rationale for, and benefits derivable from the proposed Portland natural gas-fired cogeneration plant, to be located beside the former Hearn power station near the Leslie Street Spit in Toronto, are discussed. The justification for and the single most important benefit promised by the proposed plant is that it could help Ontario achieve its coal phase-out target by displacing 100 per cent of the annual output of the Lakeview coal--fired power plant in Mississauga, as well as six per cent of the annual output of the Nanticoke coal-fired power plant, in total supplying about 10 per cent of Toronto's electricity needs and providing steam to heat several office towers in downtown Toronto. Other benefits discussed include substantially improved air quality, reduced incidence of asthma and heart attacks, a more reliable power supply for Toronto, some 500 new jobs during construction, and 25 to 35 permanent jobs to operate the plant. The Fact Sheet also offers suggestions on how to generate political support for this project in particular and for renewable power sources in general

  3. Continuous-time random walks with reset events. Historical background and new perspectives

    Science.gov (United States)

    Montero, Miquel; Masó-Puigdellosas, Axel; Villarroel, Javier

    2017-09-01

    In this paper, we consider a stochastic process that may experience random reset events which relocate the system to its starting position. We focus our attention on a one-dimensional, monotonic continuous-time random walk with a constant drift: the process moves in a fixed direction between the reset events, either by the effect of the random jumps, or by the action of a deterministic bias. However, the orientation of its motion is randomly determined after each restart. As a result of these alternating dynamics, interesting properties do emerge. General formulas for the propagator as well as for two extreme statistics, the survival probability and the mean first-passage time, are also derived. The rigor of these analytical results is verified by numerical estimations, for particular but illuminating examples.

  4. Modelling of air flow supply in a room at variable regime by using both K - E and spalart - allmaras turbulent model

    Science.gov (United States)

    Korbut, Vadim; Voznyak, Orest; Sukholova, Iryna; Myroniuk, Khrystyna

    2017-12-01

    The abstract is to The article is devoted to the decision of actual task of air distribution efficiency increasing with the help of swirl and spread air jets to provide normative parameters of air in the production apartments. The mathematical model of air supply with swirl and spread air jets in that type of apartments is improved. It is shown that for reachin of air distribution maximal efficiency it is necessary to supply air by air jets, that intensively extinct before entering into a working area. Simulation of air flow performed with the help of CFD FLUENT (Ansys FLUENT). Calculations of the equation by using one-parameter model of turbulence Spalart-Allmaras are presented. The graphical and the analytical dependences on the basis of the conducted experimental researches, which can be used in subsequent engineering calculations, are shown out. Dynamic parameters of air flow that is created due to swirl and spread air jets at their leakage at variable regime and creation of dynamic microclimate in a room has been determined. Results of experimental investigations of air supply into the room by air distribution device which creates swirl air jets for creation more intensive turbulization air flow in the room are presented. Obtained results of these investigations give possibility to realize engineer calculations of air distribution with swirl air jets. The results of theoretical researches of favourable influence of dynamic microclimate to the man are presented. When using dynamic microclimate, it's possible to decrease conditioning and ventilation system expenses. Human organism reacts favourably on short lasting deviations from the rationed parameters of air environment.

  5. Cortical dynamics of feature binding and reset: control of visual persistence.

    Science.gov (United States)

    Francis, G; Grossberg, S; Mingolla, E

    1994-04-01

    An analysis of the reset of visual cortical circuits responsible for the binding or segmentation of visual features into coherent visual forms yields a model that explains properties of visual persistence. The reset mechanisms prevent massive smearing of visual percepts in response to rapidly moving images. The model simulates relationships among psychophysical data showing inverse relations of persistence to flash luminance and duration, greater persistence of illusory contours than real contours, a U-shaped temporal function for persistence of illusory contours, a reduction of persistence due to adaptation with a stimulus of like orientation, an increase of persistence with spatial separation of a masking stimulus. The model suggests that a combination of habituative, opponent, and endstopping mechanisms prevent smearing and limit persistence. Earlier work with the model has analyzed data about boundary formation, texture segregation, shape-from-shading, and figure-ground separation. Thus, several types of data support each model mechanism and new predictions are made.

  6. Persistent resetting of the cerebral oxygen/glucose uptake ratio by brain activation

    DEFF Research Database (Denmark)

    Madsen, P L; Hasselbalch, S G; Hagemann, L P

    1995-01-01

    fraction of the activation-induced excess glucose uptake. These data confirm earlier reports that brain activation can induce resetting of the cerebral oxygen/glucose consumption ratio, and indicate that the resetting persists for a long period after cerebral activation has been terminated and physiologic......Global cerebral blood flow (CBF), global cerebral metabolic rates for oxygen (CMRO2), and for glucose (CMRglc), and lactate efflux were measured during rest and during cerebral activation induced by the Wisconsin card sorting test. Measurements were performed in healthy volunteers using the Kety......-Schmidt technique. Global CMRO2 was unchanged during cerebral activation, whereas global CBF and global CMRglc both increased by 12%, reducing the molar ratio of oxygen to glucose consumption from 6.0 during baseline conditions to 5.4 during activation. Data obtained in the period following cerebral activation...

  7. Air conditioning system and component therefore distributing air flow from opposite directions

    Science.gov (United States)

    Obler, H. D.; Bauer, H. B. (Inventor)

    1974-01-01

    The air conditioning system comprises a plurality of separate air conditioning units coupled to a common supply duct such that air may be introduced into the supply duct in two opposite flow directions. A plurality of outlets such as registers or auxiliary or branch ducts communicate with the supply duct and valve means are disposed in the supply duct at at least some of the outlets for automatically channelling a controllable amount of air from the supply duct to the associated outlet regardless of the direction of air flow within the supply duct. The valve means comprises an automatic air volume control apparatus for distribution within the air supply duct into which air may be introduced from two opposite directions. The apparatus incorporates a freely swinging movable vane in the supply duct to automatically channel into the associated outlet only the deflected air flow which has the higher relative pressure.

  8. Calculation methods for air supply design in industrial facilities. Literature review

    Energy Technology Data Exchange (ETDEWEB)

    Hagstroem, K; Siren, K; Zhivov, A M

    1999-09-01

    The objectives of air distribution systems for warm air heating, ventilating, and air-conditioning are to create the proper thermal environment conditions in the occupied zone (combination of temperature, humidity, and air movement), and to control vapor and air born particle concentration within the target levels set by the process requirements and/or threshold limit values based on health effects, fire and explosion prevention, or other considerations. HVAC systems designs are constrained by existing codes, standards, and guidelines, which specify some minimum requirements for the HVAC system elements, occupant`s and process environmental quality and safety. There is a variety of different methods consulting engineers use to design room air diffusion and to select and size air diffusers, such as assumption of perfect mixing, design methods employing the empirical relations determined through research, such as the air diffusion performance index (ADPI), air jet theory and computational fluid dynamics (CFD) codes. Air supplied into the room through the various types of outlets (grills, ceiling mounted air diffusers, perforated panels etc.), is distributed by turbulent air jets. In mixing type air distribution systems, these air jets are the primary factor affecting room air motion. Numerous theoretical and experimental studies that developed a solid base for turbulent air jets theory were conducted concurrently in different countries (Germany, Sweden, Russia, U.K., USA) from the 1930`s through the 1980`s. Design methods based on air jet theory allows for the prediction of extreme values of air velocities and air temperatures in the occupied zone of empty spaces. Current air jet theory techniques account for the effects of buoyancy, confinement, jets interaction. For many conditions of jet discharge, it is possible to analyze jet performance and determine: the angle of divergence of the jet boundary; the velocity patterns along heated or chilled the jet axis; the

  9. Multi-function ring magnet power supply for rapid-cycling synchrotrons

    International Nuclear Information System (INIS)

    Praeg, W.F.

    1985-01-01

    Ring magnet power supply (RMPS) circuits that produce a wide range of magnet current waveshapes for rapid-cycling synchrotrons (RCS) are described. The shapes range from long flat-tops separated by a biased dual frequency cosine wave to those having a flat-bottom (injection), followed by a lower frequency cosine half wave (acceleration), a flat-top (extraction), and a higher frequency cosine half wave (magnet reset). Applications of these circuits for proposed synchrotrons are outlined. Solid-state switching circuits and the results of proof-of-concept tests are shown. 8 refs., 12 figs

  10. Quantum memory Write, read and reset

    CERN Document Server

    Wu Tai Tsun; Wu, Tai Tsun; Yu, Ming Lun

    2002-01-01

    A model is presented for the quantum memory, the content of which is a pure quantum state. In this model, the fundamental operations of writing on, reading, and resetting the memory are performed through scattering from the memory. The requirement that the quantum memory must remain in a pure state after scattering implies that the scattering is of a special type, and only certain incident waves are admissible. An example, based on the Fermi pseudo-potential in one dimension, is used to demonstrate that the requirements on the scattering process are consistent and can be satisfied. This model is compared with the commonly used model for the quantum memory; the most important difference is that the spatial dimensions and interference play a central role in the present model.

  11. Air Quality and Health Impacts of an Aviation Biofuel Supply Chain Using Forest Residue in the Northwestern United States.

    Science.gov (United States)

    Ravi, Vikram; Gao, Allan H; Martinkus, Natalie B; Wolcott, Michael P; Lamb, Brian K

    2018-04-03

    Forest residue is a major potential feedstock for second-generation biofuel; however, little knowledge exists about the environmental impacts of the development and production of biofuel from such a feedstock. Using a high-resolution regional air quality model, we estimate the air quality impacts of a forest residue based aviation biofuel supply chain scenario in the Pacific Northwestern United States. Using two potential supply chain regions, we find that biomass and biofuel hauling activities will add simulation. Using BenMAP, a health impact assessment tool, we show that avoiding slash pile burning results in a decrease in premature mortality as well as several other nonfatal and minor health effects. In general, we show that most air quality and health benefits result primarily from avoided slash pile burning emissions.

  12. Optimization of a PCRAM Chip for high-speed read and highly reliable reset operations

    Science.gov (United States)

    Li, Xiaoyun; Chen, Houpeng; Li, Xi; Wang, Qian; Fan, Xi; Hu, Jiajun; Lei, Yu; Zhang, Qi; Tian, Zhen; Song, Zhitang

    2016-10-01

    The widely used traditional Flash memory suffers from its performance limits such as its serious crosstalk problems, and increasing complexity of floating gate scaling. Phase change random access memory (PCRAM) becomes one of the most potential nonvolatile memories among the new memory techniques. In this paper, a 1M-bit PCRAM chip is designed based on the SMIC 40nm CMOS technology. Focusing on the read and write performance, two new circuits with high-speed read operation and highly reliable reset operation are proposed. The high-speed read circuit effectively reduces the reading time from 74ns to 40ns. The double-mode reset circuit improves the chip yield. This 1M-bit PCRAM chip has been simulated on cadence. After layout design is completed, the chip will be taped out for post-test.

  13. The Air Force Mobile Forward Surgical Team (MFST): Using the Estimating Supplies Program to Validate Clinical Requirement

    National Research Council Canada - National Science Library

    Nix, Ralph E; Onofrio, Kathleen; Konoske, Paula J; Galarneau, Mike R; Hill, Martin

    2004-01-01

    .... The primary objective of the study was to provide the Air Force with the ability to validate clinical requirements of the MFST assemblage, with the goal of using NHRC's Estimating Supplies Program (ESP...

  14. Resetting in time of recordings in ultra-fast cinematography

    International Nuclear Information System (INIS)

    Leduc, Michel

    In ultra-fast cinematography and photography the treatment and interpretation of the data contained in the recordings demand extremely precise readjustments in time. In the case of whole-image recordings by electro-optical cameras or flash sources the problem is resolved by the use of a chronometric unit taking into account the different events. For naving slit or spectrographic recordings the problem must be detail with differently and marking devices will be used to print resetting pulses on the recording themselves. Different marking devices are described [fr

  15. Reduced energy reqirement for air conditioning by using air diffusion with air flow from floor to ceiling

    Energy Technology Data Exchange (ETDEWEB)

    Bach, H; Dittes, W; Mangelsdorf, R; Detzer, R; Jungbaeck, E; Fitzner, K; Radtke, W; Soethout, F

    1982-02-01

    The condition of the air in the occupied zone in airconditioned rooms is influenced by the mixing of supply air with room air. When supplying air from the ceiling there is a mixing all over the room, when supplying from the floor or from desks there is a mixing region only in the lower area. Above this their is warm air from which the return air is drawn. For air supply from below the cooling load can be decreased. In combination with the possible enthalpy difference between room air and supply air this decrease of the cooling load influences the necessary air rate. The interdependence of various air conditioning systems and various air temperatures is shown with a computer program. The load factor for various air distribution system at various cooling loads have been measured in a room of (8 x 5)m/sup 2/ x 3m. Experiments in a smaller model room (scale 1:3) showed how the heat was transported from the mixing region to the stratification region. The theoretically gained influence of the supply air jets of the height of the mixing region and on the load rate could be verified by the experiments. For the design of the fresh air rate, experience has been gained by measurements with tracegas (N/sub 2/O) in a third room. In comparing calculations the annual energy consumption has been computed for a building assuming various air conditioning systems and typical operation data. From experience with the existing systems the conclusions have been drawn how air distribution from floor to ceiling can be installed and operated.

  16. Passenger evaluation of the optimum balance between fresh air supply and humidity from 7-h exposures in a simulated aircraft cabin

    DEFF Research Database (Denmark)

    Strøm-Tejsen, Peter; Wyon, David Peter; Lagercrantz, Love Per

    2007-01-01

    A 21-seat section of an aircraft cabin with realistic pollution sources was built inside a climate chamber capable of providing fresh outside air at very low humidity. Maintaining a constant 200 l/s rate of total air supply, i.e. recircu-lated and make-up air, to the cabin, experiments simulating 7...

  17. Saccadic reaction times to audiovisual stimuli show effects of oscillatory phase reset.

    Directory of Open Access Journals (Sweden)

    Adele Diederich

    Full Text Available Initiating an eye movement towards a suddenly appearing visual target is faster when an accessory auditory stimulus occurs in close spatiotemporal vicinity. Such facilitation of saccadic reaction time (SRT is well-documented, but the exact neural mechanisms underlying the crossmodal effect remain to be elucidated. From EEG/MEG studies it has been hypothesized that coupled oscillatory activity in primary sensory cortices regulates multisensory processing. Specifically, it is assumed that the phase of an ongoing neural oscillation is shifted due to the occurrence of a sensory stimulus so that, across trials, phase values become highly consistent (phase reset. If one can identify the phase an oscillation is reset to, it is possible to predict when temporal windows of high and low excitability will occur. However, in behavioral experiments the pre-stimulus phase will be different on successive repetitions of the experimental trial, and average performance over many trials will show no signs of the modulation. Here we circumvent this problem by repeatedly presenting an auditory accessory stimulus followed by a visual target stimulus with a temporal delay varied in steps of 2 ms. Performing a discrete time series analysis on SRT as a function of the delay, we provide statistical evidence for the existence of distinct peak spectral components in the power spectrum. These frequencies, although varying across participants, fall within the beta and gamma range (20 to 40 Hz of neural oscillatory activity observed in neurophysiological studies of multisensory integration. Some evidence for high-theta/alpha activity was found as well. Our results are consistent with the phase reset hypothesis and demonstrate that it is amenable to testing by purely psychophysical methods. Thus, any theory of multisensory processes that connects specific brain states with patterns of saccadic responses should be able to account for traces of oscillatory activity in observable

  18. A self-resetting spiking phase-change neuron

    Science.gov (United States)

    Cobley, R. A.; Hayat, H.; Wright, C. D.

    2018-05-01

    Neuromorphic, or brain-inspired, computing applications of phase-change devices have to date concentrated primarily on the implementation of phase-change synapses. However, the so-called accumulation mode of operation inherent in phase-change materials and devices can also be used to mimic the integrative properties of a biological neuron. Here we demonstrate, using physical modelling of nanoscale devices and SPICE modelling of associated circuits, that a single phase-change memory cell integrated into a comparator type circuit can deliver a basic hardware mimic of an integrate-and-fire spiking neuron with self-resetting capabilities. Such phase-change neurons, in combination with phase-change synapses, can potentially open a new route for the realisation of all-phase-change neuromorphic computing.

  19. A self-resetting spiking phase-change neuron.

    Science.gov (United States)

    Cobley, R A; Hayat, H; Wright, C D

    2018-05-11

    Neuromorphic, or brain-inspired, computing applications of phase-change devices have to date concentrated primarily on the implementation of phase-change synapses. However, the so-called accumulation mode of operation inherent in phase-change materials and devices can also be used to mimic the integrative properties of a biological neuron. Here we demonstrate, using physical modelling of nanoscale devices and SPICE modelling of associated circuits, that a single phase-change memory cell integrated into a comparator type circuit can deliver a basic hardware mimic of an integrate-and-fire spiking neuron with self-resetting capabilities. Such phase-change neurons, in combination with phase-change synapses, can potentially open a new route for the realisation of all-phase-change neuromorphic computing.

  20. New energy replacement method for resonant power supplies

    International Nuclear Information System (INIS)

    Karady, G.G.; Thiessen, H.A.

    1989-01-01

    The Resonant Power Supply is an economically and technically advanced solution for Rapid Cycling Accelerators. Several papers dealt with the design and operation of these power supplies, however, the energy replacement methods were not discussed in the past. This paper analyzes different energy-replacement methods and presents a new method. This method uses a 24-pulse converter to regulate the magnet current during flat-top and injection periods and replaces the energy loss by charging the accelerator capacitor bank during the flat-top, reset and injection periods, charge is injected in the circuit during the acceleration period, when it replaces the energy loss. This paper compares the new method with the existing ones. The analyses proved the feasibility of the proposed method. The operation of the proposed method was verified by a model experiment, which showed that the new circuit can be controlled accurately and operates with smaller disturbances to the power line than the existing systems. 2 refs., 6 figs., 1 tab

  1. Compliance-Free, Digital SET and Analog RESET Synaptic Characteristics of Sub-Tantalum Oxide Based Neuromorphic Device.

    Science.gov (United States)

    Abbas, Yawar; Jeon, Yu-Rim; Sokolov, Andrey Sergeevich; Kim, Sohyeon; Ku, Boncheol; Choi, Changhwan

    2018-01-19

    A two terminal semiconducting device like a memristor is indispensable to emulate the function of synapse in the working memory. The analog switching characteristics of memristor play a vital role in the emulation of biological synapses. The application of consecutive voltage sweeps or pulses (action potentials) changes the conductivity of the memristor which is considered as the fundamental cause of the synaptic plasticity. In this study, a neuromorphic device using an in-situ growth of sub-tantalum oxide switching layer is fabricated, which exhibits the digital SET and analog RESET switching with an electroforming process without any compliance current (compliance free). The process of electroforming and SET is observed at the positive sweeps of +2.4 V and +0.86 V, respectively, while multilevel RESET is observed with the consecutive negative sweeps in the range of 0 V to -1.2 V. The movement of oxygen vacancies and gradual change in the anatomy of the filament is attributed to digital SET and analog RESET switching characteristics. For the Ti/Ta 2 O 3-x /Pt neuromorphic device, the Ti top and Pt bottom electrodes are considered as counterparts of the pre-synaptic input terminal and a post-synaptic output terminal, respectively.

  2. 77 FR 20625 - Air Pollution Control: Proposed Action on Clean Air Act Grants to the Idaho Department of...

    Science.gov (United States)

    2012-04-05

    ...The U.S. EPA has made a proposed determination that reduction in expenditures of non-Federal funds for the Idaho Department of Environmental Quality (IDEQ) in support of its continuing air program under Clean Air Act (CAA) Section 105 for the period of calendar year 2010 was not selective relative to the expenditures of all other executive branch agencies in the State for the same period. This determination, when final, will reset IDEQ's required recipient maintenance of effort level for 2010 and 2011, retain its federal award for the 2010 and 2011 grant years, and allow IDEQ to remain eligible for a Sec. 105 grant for 2012 and beyond.

  3. Neuro-optimal operation of a variable air volume HVAC and R system

    International Nuclear Information System (INIS)

    Ning Min; Zaheeruddin, M.

    2010-01-01

    Low operational efficiency especially under partial load conditions and poor control are some reasons for high energy consumption of heating, ventilation, air conditioning and refrigeration (HVAC and R) systems. To improve energy efficiency, HVAC and R systems should be efficiently operated to maintain a desired indoor environment under dynamic ambient and indoor conditions. This study proposes a neural network based optimal supervisory operation strategy to find the optimal set points for chilled water supply temperature, discharge air temperature and VAV system fan static pressure such that the indoor environment is maintained with the least chiller and fan energy consumption. To achieve this objective, a dynamic system model is developed first to simulate the system behavior under different control schemes and operating conditions. A multi-layer feed forward neural network is constructed and trained in unsupervised mode to minimize the cost function which is comprised of overall energy cost and penalty cost when one or more constraints are violated. After training, the network is implemented as a supervisory controller to compute the optimal settings for the system. Simulation results show that compared to the conventional night reset operation scheme, the optimal operation scheme saves around 10% energy under full load condition and 19% energy under partial load conditions.

  4. Augmented brain function by coordinated reset stimulation with slowly varying sequences

    Directory of Open Access Journals (Sweden)

    Magteld eZeitler

    2015-03-01

    Full Text Available Several brain disorders are characterized by abnormally strong neuronal synchrony. Coordinated Reset (CR stimulation was developed to selectively counteract abnormal neuronal synchrony by desynchronization. For this, phase resetting stimuli are delivered to different subpopulations in a timely coordinated way. In neural networks with spike timing-dependent plasticity CR stimulation may eventually lead to an anti-kindling, i.e. an unlearning of abnormal synaptic connectivity and abnormal synchrony. The spatiotemporal sequence by which all stimulation sites are stimulated exactly once is called the stimulation site sequence, or briefly sequence. So far, in simulations, pre-clinical and clinical applications CR was applied either with fixed sequences or rapidly varying sequences (RVS. In this computational study we show that appropriate repetition of the sequence with occasional random switching to the next sequence may significantly improve the anti-kindling effect of CR. To this end, a sequence is applied many times before randomly switching to the next sequence. This new method is called SVS CR stimulation, i.e. CR with slowly varying sequences. In a neuronal network with strong short-range excitatory and weak long-range inhibitory dynamic couplings SVS CR stimulation turns out to be superior to CR stimulation with fixed sequences or RVS.

  5. Augmented brain function by coordinated reset stimulation with slowly varying sequences.

    Science.gov (United States)

    Zeitler, Magteld; Tass, Peter A

    2015-01-01

    Several brain disorders are characterized by abnormally strong neuronal synchrony. Coordinated Reset (CR) stimulation was developed to selectively counteract abnormal neuronal synchrony by desynchronization. For this, phase resetting stimuli are delivered to different subpopulations in a timely coordinated way. In neural networks with spike timing-dependent plasticity CR stimulation may eventually lead to an anti-kindling, i.e., an unlearning of abnormal synaptic connectivity and abnormal synchrony. The spatiotemporal sequence by which all stimulation sites are stimulated exactly once is called the stimulation site sequence, or briefly sequence. So far, in simulations, pre-clinical and clinical applications CR was applied either with fixed sequences or rapidly varying sequences (RVS). In this computational study we show that appropriate repetition of the sequence with occasional random switching to the next sequence may significantly improve the anti-kindling effect of CR. To this end, a sequence is applied many times before randomly switching to the next sequence. This new method is called SVS CR stimulation, i.e., CR with slowly varying sequences. In a neuronal network with strong short-range excitatory and weak long-range inhibitory dynamic couplings SVS CR stimulation turns out to be superior to CR stimulation with fixed sequences or RVS.

  6. Desynchronization boost by non-uniform coordinated reset stimulation in ensembles of pulse-coupled neurons

    Science.gov (United States)

    Lücken, Leonhard; Yanchuk, Serhiy; Popovych, Oleksandr V.; Tass, Peter A.

    2013-01-01

    Several brain diseases are characterized by abnormal neuronal synchronization. Desynchronization of abnormal neural synchrony is theoretically compelling because of the complex dynamical mechanisms involved. We here present a novel type of coordinated reset (CR) stimulation. CR means to deliver phase resetting stimuli at different neuronal sub-populations sequentially, i.e., at times equidistantly distributed in a stimulation cycle. This uniform timing pattern seems to be intuitive and actually applies to the neural network models used for the study of CR so far. CR resets the population to an unstable cluster state from where it passes through a desynchronized transient, eventually resynchronizing if left unperturbed. In contrast, we show that the optimal stimulation times are non-uniform. Using the model of weakly pulse-coupled neurons with phase response curves, we provide an approach that enables to determine optimal stimulation timing patterns that substantially maximize the desynchronized transient time following the application of CR stimulation. This approach includes an optimization search for clusters in a low-dimensional pulse coupled map. As a consequence, model-specific non-uniformly spaced cluster states cause considerably longer desynchronization transients. Intriguingly, such a desynchronization boost with non-uniform CR stimulation can already be achieved by only slight modifications of the uniform CR timing pattern. Our results suggest that the non-uniformness of the stimulation times can be a medically valuable parameter in the calibration procedure for CR stimulation, where the latter has successfully been used in clinical and pre-clinical studies for the treatment of Parkinson's disease and tinnitus. PMID:23750134

  7. Air pollution and health impact emboided in supply chains in China

    Science.gov (United States)

    Zhang, Q.

    2016-12-01

    Close economic linkage and consequent air pollutant emissions embodied in trade among Chinese regions have been widely discussed. Yet the related health impacts across regions remain unaddressed. Here, we integrated four state-of-the-art models to for the first time estimate PM2.5 related premature deaths along the supply chains across seven Chinese regions, and we quantified cross impacts among receptors, producers, assemblers, consumers, and sectors. We find that, due to the atmospheric transport, in 2010, 33% of national premature deaths were caused by emissions released in other regions, and the trans-boundary effect is more significant from north to south and from east to west. From a supply chain perspective, 38% of national premature deaths were associated with production for in a region to supply other regions' consumption. For instance, 20-35% of premature deaths related to the highly developed east coastal regions' consumption were caused by emissions in the central and western regions. Sectorally, similar to the widely concerned heavy industries, direct emissions from agricultural and residential activities together contributed near half of national total premature deaths, posing a great challenge for recent pollution reduction action, which are mainly focusing on industrial restructuring. Our results emphasize the importance of regarding pollution related premature deaths in China as a national systemic problem, instead of targeting the pollution producers (region or sector) in isolation. Multilateral and multi-sector cooperation is in urgent need to improve the national atmospheric environment.

  8. An Analysis of Shelf Space Allocation at the Wright-Patterson Air Force Base Commissary.

    Science.gov (United States)

    1987-09-01

    Company performed a major shelf space allocation study involving 59 of their stores. The study involved planning and executing a shelf by shelf reset...Betty Crocker Chocolate .a9 2 Betty CrocKer Yellow .93 3 Betty Crocker Devils Food .92 4 Betty Crocker Choc . Choc . Chip .94 5 Betty Crocker German...Headquarters Air Force Commissary Services. ACOS Executive Summary. 28 January 19d6. 12. deadquarters Air Force Commissary Services. Store _Layout

  9. 42 CFR 84.159 - Man tests for gases and vapors; supplied-air respirators; general performance requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Man tests for gases and vapors; supplied-air respirators; general performance requirements. 84.159 Section 84.159 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES...

  10. 78 FR 51184 - Air Pollution Control: Proposed Actions on Clean Air Act Section 105 Grant to the Lane Regional...

    Science.gov (United States)

    2013-08-20

    ...The EPA has made a proposed determination that a reduction in recurring expenditures of non-Federal funds for the Lane Regional Air Protection Agency (LRAPA) in Eugene, Oregon is a result of agency wide non-selective reductions in expenditures. This determination, when final, will permit the LRAPA to continue to receive grant funding under Section 105 of the Clean Air Act for the state fiscal year (SFY) 2014. This determination will also reset the LRAPA required maintenance of effort level for SFY 2012 and 2013 to reflect the non-selective reductions made to address reductions in revenue due to adverse economic conditions in Lane County, Oregon.

  11. Resetting dynamic behaviour of pipework systems; Recalage du comportement dynamique des reseaux de tuyauteries

    Energy Technology Data Exchange (ETDEWEB)

    Gaudin, M [Electricite de France (EDF), Direction des Etudes et Recherches, 92 - Clamart (France)

    1998-12-31

    Resetting models is applied to electricity generating plant pipework systems. A frequency approach to the problem is made in an original way thanks to the use of precise dynamic rigidity matrices. The method assumes two kinds of unknown: the usually processed mechanical characteristics (Young`s Modulus, density etc.) and new resetting parameters acting on the dynamic behaviour of unknown connections. As the latter have a very wide range of possible variation, they benefit from a change of variable which allows the assumptions formulated to be complied with. The minimized cost function is based on a error in load. The frequencies required for building it are automatically selected thanks to different tests on measurements. Minimization uses a sensitivity technique linked with a method of least standard squares. The method has been programmed in Fortran 90 within the CIRCUS code and tried out on various examples which were simulated and sound effects cases as well as an actual case. (author). 128 refs.

  12. Resetting dynamic behaviour of pipework systems; Recalage du comportement dynamique des reseaux de tuyauteries

    Energy Technology Data Exchange (ETDEWEB)

    Gaudin, M. [Electricite de France (EDF), Direction des Etudes et Recherches, 92 - Clamart (France)

    1997-12-31

    Resetting models is applied to electricity generating plant pipework systems. A frequency approach to the problem is made in an original way thanks to the use of precise dynamic rigidity matrices. The method assumes two kinds of unknown: the usually processed mechanical characteristics (Young`s Modulus, density etc.) and new resetting parameters acting on the dynamic behaviour of unknown connections. As the latter have a very wide range of possible variation, they benefit from a change of variable which allows the assumptions formulated to be complied with. The minimized cost function is based on a error in load. The frequencies required for building it are automatically selected thanks to different tests on measurements. Minimization uses a sensitivity technique linked with a method of least standard squares. The method has been programmed in Fortran 90 within the CIRCUS code and tried out on various examples which were simulated and sound effects cases as well as an actual case. (author). 128 refs.

  13. Experimental investigation on a turbine compressor for air supply system of a fuel cell

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, Masayasu [Sumitomo Heavy Industries, Ltd., Yokosuka (Japan); Tsuchiyama, Syozo [Shipbuilding Research Association, Minato-ku, Tokyo (Japan)

    1996-12-31

    This report covers part of a joint study on a PEFC propulsion system for surface ships, summarized in a presentation to this Seminar, entitled {open_quotes}Study on a Polymer Electrolyte Fuel Cell (PEFC) Propulsion System for Surface Ships{close_quotes}, and which envisages application to a 1,500 DWT cargo vessel. The aspect treated here concerns a study on the air supply system for the PEFC, with particular reference to system components.

  14. PENGELOLAAN MATA AIR UNTUK PENYEDIAAN AIR RUMAHTANGGA BERKELANJUTAN DI LERENG SELATAN GUNUNGAPI MERAPI (Springs Management for Sustainability Domestic Water Supply in the South West of Merapi Volcano Slope

    Directory of Open Access Journals (Sweden)

    Sudarmadji Sudarmadji

    2016-02-01

    Full Text Available ABSTRAK Mata air merupakan pemunculan air tanah ke permukaan tanah. Pemanfaatan mata air sangat beragam, antara lain penggunaan untuk keperluan air minum, irigasi, perikanan, untuk obyek wisata. Mata air mempunyai debit terbatas, namun kualitasnya baik, penggunaannya beragam, hal tersebut sering terjadi konflik pemanfaatan. Di saat musim kemarau, beberapa mata air merupakan sumber air satu-satunya di suatu tempat, sehingga pengelolaannya harus dilakukan secara baik. Penelitian ini bertujuan untuk mempelajari pengelolaan mata air berbasis teknologi tepat guna dalam penyediaan air rumahtangga di lereng selatan Gunungapi Merapi. Penelitian dilakukan dengan survei dan observasi di lapangan terhadap mata air yang digunakan untuk penyediaan air rumahtangga. Sejumlah responden pengguna mata air dan tokoh masyarakat setempat diwawancarai secara bebas dan terstruktur untuk memperoleh data pengelolaan mata air. Hasil penelitian menunjukkan bahwa kondisi lingkungan dan karakteristik mata air, pengetahuan masyarakat dan budaya lokal yang beragam akan berpengaruh terhadap pengelolaanmata air. Perkembangan teknologi tidak dapat diabaikan dalam pengelolaan sumberdaya air. Hal ini dapat dipadukan dengan budaya masyarakat setempat dalam pengelolaan mata air, sehingga dapat diperoleh manfaat yang optimal dan kesinambungan fungsi dan manfaat mata air tersebut.   ABSTRACT Spring is the groundwater which comes out on ground surface. The use of water from springs is very diverse, varying from water for drinking, irrigation, fisheries, even for tourism. The springs usually have a limited discharge but the water quality from springs is good, therefore they are often facing some conflicts in utilization. In the dry season, in fact the springs are the only source of water supply; therefore the management of the spring should be done properly. This research aims to study the spring management based on appropriate technology in relation to household water supply in the

  15. The Inspection Process of the Army Reset Program for Equipment for Units Returning from Operation Iraqi Freedom

    National Research Council Canada - National Science Library

    2008-01-01

    The subject of this report directly applies to the work of DoD civilian and military personnel responsible for the reset of equipment provided to the warfighter deployed in support of Operation Iraqi Freedom...

  16. Using the Estimating Supplies Program to Develop Materiel Solutions for the U.S. Air Force Aeromedical Evacuation In-Flight Kit (FFQDM)

    National Research Council Canada - National Science Library

    Hopkins, Curtis; Nix, Ralph; Pang, Gerry; Konoske, Paula

    2008-01-01

    ... NHRC's medical modeling tool the Estimating Supplies Program (ESP) for the development and management of Air Force medical Allowance Standards as a baseline for standardization throughout the services...

  17. Nonlinear reset integrator control design: Application to the active suspension control of vehicles

    OpenAIRE

    Acho Zuppa, Leonardo

    2014-01-01

    We present an unexampled reset integrator control design based on the Clegg integrator system. Using an appropriate mathematical model of our Clegg integrator controller, stability proof of the closed-loop system applied to the vibration control problem of a second-order system is shown without invoking hybrid system theory. Furthermore, we illustrate the pplicability of our controller, from the numerical experiment point of view, to the suspension vibration control of vehicles.

  18. A thorough investigation of the progressive reset dynamics in HfO2-based resistive switching structures

    International Nuclear Information System (INIS)

    Lorenzi, P.; Rao, R.; Irrera, F.; Suñé, J.; Miranda, E.

    2015-01-01

    According to previous reports, filamentary electron transport in resistive switching HfO 2 -based metal-insulator-metal structures can be modeled using a diode-like conduction mechanism with a series resistance. Taking the appropriate limits, the model allows simulating the high (HRS) and low (LRS) resistance states of the devices in terms of exponential and linear current-voltage relationships, respectively. In this letter, we show that this simple equivalent circuit approach can be extended to represent the progressive reset transition between the LRS and HRS if a generalized logistic growth model for the pre-exponential diode current factor is considered. In this regard, it is demonstrated here that a Verhulst logistic model does not provide accurate results. The reset dynamics is interpreted as the sequential deactivation of multiple conduction channels spanning the dielectric film. Fitting results for the current-voltage characteristics indicate that the voltage sweep rate only affects the deactivation rate of the filaments without altering the main features of the switching dynamics

  19. An innovative system for supplying air and fuel mixture to a combustion chamber of an engine

    Science.gov (United States)

    Saikumar, G. R. Bharath

    2018-04-01

    Conventional carburetors are being used since decades to ensure that the desired ratio of air and fuel enters the combustion chamber for combustion for the purpose of generating power in an Spark Ignition(SI) internal combustion engine. However to increase the efficiency, the carburetor system is gradually being replaced by fuel injection systems. Fuel injection systems use injectors to supply pressurized fuel into the combustion chamber. Owing to the high initial and maintenance cost, carburetors are still ruling in the low cost vehicle domain. An innovative concept is conceived, which is an alternative method to the carburetor system to supply the air and fuel mixture to a combustion chamber of an engine. This system comprises of an inner hollow cylinder with minute holes drilled along its length with an outer cylinder capable of sliding along its length or its longitudinal axis. This system is placed in the venturi instead of the conventional carburetor system. Fuel enters from the bottom inlet of the inner cylinder and flows out through the holes provided along its length. The fuel flow from the inner cylinder is dependent on the size and the number of holes exposed at that instance by the sliding outer cylinder which in turn is connected to the throttle or accelerator.

  20. Impact Analysis of Air Pollutant Emission Policies on Thermal Coal Supply Chain Enterprises in China

    Directory of Open Access Journals (Sweden)

    Xiaopeng Guo

    2014-12-01

    Full Text Available Spurred by the increasingly serious air pollution problem, the Chinese government has launched a series of policies to put forward specific measures of power structure adjustment and the control objectives of air pollution and coal consumption. Other policies pointed out that the coal resources regional blockades will be broken by improving transportation networks and constructing new logistics nodes. Thermal power takes the largest part of China’s total installed power generation capacity, so these policies will undoubtedly impact thermal coal supply chain member enterprises. Based on the actual situation in China, this paper figures out how the member enterprises adjust their business decisions to satisfy the requirements of air pollution prevention and control policies by establishing system dynamic models of policy impact transfer. These dynamic analyses can help coal enterprises and thermal power enterprises do strategic environmental assessments and find directions of sustainable development. Furthermore, the policy simulated results of this paper provide the Chinese government with suggestions for policy-making to make sure that the energy conservation and emission reduction policies and sustainable energy policies can work more efficiently.

  1. Development of a model for activated sludge aeration systems: linking air supply, distribution, and demand.

    Science.gov (United States)

    Schraa, Oliver; Rieger, Leiv; Alex, Jens

    2017-02-01

    During the design of a water resource recovery facility, it is becoming industry practice to use simulation software to assist with process design. Aeration is one of the key components of the activated sludge process, and is one of the most important aspects of modelling wastewater treatment systems. However, aeration systems are typically not modelled in detail in most wastewater treatment process modelling studies. A comprehensive dynamic aeration system model has been developed that captures both air supply and demand. The model includes sub-models for blowers, pipes, fittings, and valves. An extended diffuser model predicts both oxygen transfer efficiency within an aeration basin and pressure drop across the diffusers. The aeration system model allows engineers to analyse aeration systems as a whole to determine biological air requirements, blower performance, air distribution, control valve impacts, controller design and tuning, and energy costs. This enables engineers to trouble-shoot the entire aeration system including process, equipment and controls. It also allows much more realistic design of these highly complex systems.

  2. Study of an electrical heating system with ductless air supply and shape-stabilized PCM for thermal storage

    International Nuclear Information System (INIS)

    Lin, Kunping; Zhang, Yinping; Di, Hongfa; Yang, Rui

    2007-01-01

    A kind of electrical floor heating system with a shape-stabilized phase change material (PCM) which has been studied at Tsinghua University in our previous studies, can provide space heating during the whole day and can be controlled conventionally. However, this is not suitable for office buildings where no space heating is needed at night. The effective control is very important for the heating system in such buildings. In this paper, we studied a kind of new electrical floor heating system with ductless air supply and shape-stabilized PCM for thermal storage in order to overcome the shortcomings of the passive under-floor electric heating system with thermal storage. In this paper, we investigated its thermal performance by experiments and simulation, calculated the effects of various factors and discussed the application feasibility in different climate regions. The results show that the total electrical energy consumption was shifted from the peak period to the off-peak period, which would provide significant economic benefits because of the different day and night electricity tariffs. The system can be designed by choosing PCM with proper melting temperature and be controlled by varying velocity of air supply in different conditions

  3. Contribution of 222Rn in domestic water supplies to 222Rn in indoor air in Colorado homes

    International Nuclear Information System (INIS)

    Lawrence, E.P.; Wanty, R.B.; Nyberg, P.

    1992-01-01

    The contribution of 222Rn from domestic water wells to indoor air was investigated in a study of 28 houses near Conifer, CO. Air concentrations determined by alpha-track detectors (ATDs) and continuous radon monitors were compared with the predictions of a single-cell model. In many of the houses, the water supply was shown to contribute significantly to levels of indoor 222Rn. The data from the ATD study were augmented with a continuous monitoring study of a house near Lyons, CO. The well water in that house has the highest known concentration of 222Rn in water yet reported (93 MBq m-3). The temporal pattern in the indoor 222Rn concentration corresponds to water-use records. In general, it is difficult to quantify the proportion of indoor radon attributable to water use. Several lines of evidence suggest that the single-cell model underestimates this proportion. Continuous-monitoring data, although useful, are impractical due to the cost of the equipment. We propose a protocol for 222Rn measurement based on three simultaneous integrating radon detectors that may help estimate the proportion of indoor 222Rn derived from the water supply

  4. Air-supplied pinhole discharge in aqueous solution for the inactivation of Escherichia coli

    Science.gov (United States)

    Suganuma, Ryota; Yasuoka, Koichi

    2018-04-01

    An air-supplied pinhole discharge in aqueous solution has been developed to provide a short-lived and odorless bactericide to replace current conventional disinfectants such as O3, ClO-, HClO, and ClO2. The pinhole discharge that was initiated inside a water bubble generated hydrogen peroxide (H2O2) and nitrous acid (HNO2) simultaneously. The concentrations of H2O2, HNO2, and HNO3 were 16.3, 13.9, and 17.4 mg/L, respectively when flow rates of NaCl solution and air were 72 and 12.5 mL/min, respectively. The pH value of the solution was 3.87, and HO2 radicals were generated from the reaction of H2O2 with HNO2. The efficacy of sterilization of discharge-treated water was evaluated by changing the acetic solutions. A 4-orders-of-magnitude decrease in Escherichia coli survival rate was observed after treatment with a sodium citrate solution of pH 3.2 for 60 s.

  5. l-Serine Enhances Light-Induced Circadian Phase Resetting in Mice and Humans.

    Science.gov (United States)

    Yasuo, Shinobu; Iwamoto, Ayaka; Lee, Sang-Il; Ochiai, Shotaro; Hitachi, Rina; Shibata, Satomi; Uotsu, Nobuo; Tarumizu, Chie; Matsuoka, Sayuri; Furuse, Mitsuhiro; Higuchi, Shigekazu

    2017-12-01

    Background: The circadian clock is modulated by the timing of ingestion or food composition, but the effects of specific nutrients are poorly understood. Objective: We aimed to identify the amino acids that modulate the circadian clock and reset the light-induced circadian phase in mice and humans. Methods: Male CBA/N mice were orally administered 1 of 20 l-amino acids, and the circadian and light-induced phase shifts of wheel-running activity were analyzed. Antagonists of several neurotransmitter pathways were injected before l-serine administration, and light-induced phase shifts were analyzed. In addition, the effect of l-serine on the light-induced phase advance was investigated in healthy male students (mean ± SD age 22.2 ± 1.8 y) by using dim-light melatonin onset (DLMO) determined by saliva samples as an index of the circadian phase. Results: l-Serine administration enhanced light-induced phase shifts in mice (1.86-fold; P light-dark cycle by 6 h, l-serine administration slightly accelerated re-entrainment to the shifted cycle. In humans, l-serine ingestion before bedtime induced significantly larger phase advances of DLMO after bright-light exposure during the morning (means ± SEMs-l-serine: 25.9 ± 6.6 min; placebo: 12.1 ± 7.0 min; P light-induced phase resetting in mice and humans, and it may be useful for treating circadian disturbances. © 2017 American Society for Nutrition.

  6. Electricity supply. Older plants' impact on reliability and air quality

    International Nuclear Information System (INIS)

    England-Joseph, Judy A.; Adams, Charles M.; Wood, David G.; Feehan, Daniel J.; Veal, Howard F.; Skeen, John H. III; Koenigs, Melvin J.; Lichtenfeld, David I.; Seretakis, Pauline J.

    1990-09-01

    Life extension of fossil fuel plants is a relatively recent phenomenon; thus, utilities have little experience to demonstrate the longer-term operating reliability of plants with an extended service life. While utility industry officials and government and industry studies express optimism that these plants will continue to operate reliably, the officials and the studies also caution that it is too soon to determine how pursuing life extension will affect the reliability of the nation's electricity supply. According to DOE, the number of fossil fuel generating units' 30 years old or older is expected to increase from about 2,500 in 1989 to roughly 3,700 in 1998, increasing such plants' share of overall generating capacity from 13 percent in 1989 to 27 percent in 1998. EPA estimates that with existing air quality requirements, fossil fuel plant emissions will increase steadily during the coming decade. Proposed acid rain control legislation, which would affect many plants that may have their service life extended, would require utilities to significantly reduce emissions by the year 2000 but would allow utilities flexibility in deciding how and where to achieve the reductions. If such legislation is enacted, utilities generally are expected to find reducing emissions from existing plants more cost-effective than replacing them and to continue extending plants' service life. Officials of DOE and utility organizations expressed concern, however, that EPA could decide, as it did for one plant in 1988, that alterations made in extending the service life of plants exempted from the Clean Air Act would result in increased emissions and thus cause the altered plants to lose their exemption. According to the officials, the additional costs of achieving the Clean Air Act's standards could discourage some life extension projects. However, such decisions by EPA could also reduce the nation's total power plant emissions by eliminating an existing incentive to retain exempt

  7. Effect of efficient supply of pure O2 concentrated by PSA-type O2 separator on improvement of indoor air quality

    International Nuclear Information System (INIS)

    Han, Gi Bo; Jang, Jung Hee; Choi, Changsik; Lee, Tae Jin

    2016-01-01

    To minimize the cost and loss rate of energy artificial room ventilation system, the O 2 separator was suggested for the flow of the excessive ventilation amount between indoor and outdoor because the pure O 2 separated and concentrated by the O 2 separator can be supplied with the ventilation amount minimized. How the O 2 separator applies to ventilation and its operation characteristics were investigated by controlling under various conditions as well as the operation conditions optimized required for indoor air quality such as the concentration of CO 2 and O 2 . Consequently, it was known that the O 2 concentration was increased; however, the increase of the CO 2 concentration was suppressed by the sufficient supply of O 2 concentrated from the storage tank into the room despite the two persons’ breathing in the room having an inner volume of about 56m 3 . Consequently, it was concluded that the supply system of the concentrated O 2 which was stored into the tank after the production with the O 2 separator can be applied to the room ventilation system for the improvement of the indoor air quality.

  8. A thorough investigation of the progressive reset dynamics in HfO{sub 2}-based resistive switching structures

    Energy Technology Data Exchange (ETDEWEB)

    Lorenzi, P., E-mail: lorenzi@die.uniroma1.it; Rao, R.; Irrera, F. [Dipartimento di Ingegneria dell' Informazione, Elettronica e Telecomunicazioni, Università di Roma “Sapienza,” 00184 Rome (Italy); Suñé, J.; Miranda, E. [Departament d' Enginyeria Electrònica, Universitat Autònoma de Barcelona, 08193 Bellaterra (Spain)

    2015-09-14

    According to previous reports, filamentary electron transport in resistive switching HfO{sub 2}-based metal-insulator-metal structures can be modeled using a diode-like conduction mechanism with a series resistance. Taking the appropriate limits, the model allows simulating the high (HRS) and low (LRS) resistance states of the devices in terms of exponential and linear current-voltage relationships, respectively. In this letter, we show that this simple equivalent circuit approach can be extended to represent the progressive reset transition between the LRS and HRS if a generalized logistic growth model for the pre-exponential diode current factor is considered. In this regard, it is demonstrated here that a Verhulst logistic model does not provide accurate results. The reset dynamics is interpreted as the sequential deactivation of multiple conduction channels spanning the dielectric film. Fitting results for the current-voltage characteristics indicate that the voltage sweep rate only affects the deactivation rate of the filaments without altering the main features of the switching dynamics.

  9. 42 CFR 84.163 - Man test for gases and vapors; Type C supplied-air respirators, demand and pressure-demand...

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Man test for gases and vapors; Type C supplied-air respirators, demand and pressure-demand classes; test requirements. 84.163 Section 84.163 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  10. Argon-plasma-controlled optical reset in the SiO2/Cu filamentary resistive memory stack

    Science.gov (United States)

    Kawashima, T.; Yew, K. S.; Zhou, Y.; Ang, D. S.; Zhang, H. Z.; Kyuno, K.

    2018-05-01

    We show that resistive switching in the SiO2/Cu stack can be modified by a brief exposure of the oxide to an Ar plasma. The set voltage of the SiO2/Cu stack is reduced by 33%, while the breakdown voltage of the SiO2/Si stack (control) is almost unchanged. Besides, the Ar plasma treatment suppresses the negative photoconductivity or optical resistance reset effect, where the electrically formed filamentary conductive path consisting of Cu-ion and oxygen-vacancy clusters is disrupted by the recombination of the oxygen vacancies with nearby light-excited oxygen ions. From the enhanced O-H peak in the Fourier-transform infrared spectrum of the plasma-treated oxide, it is proposed that the Ar plasma has created more oxygen vacancies in the surface region of the oxide. These vacancies in turn adsorb water molecules, which act as counter anions (OH-) promoting the migration of Cu cations into the oxide and forming a more complete Cu filament that is less responsive to light. The finding points to the prospect of a control over the optical resistance reset effect by a simple surface treatment step.

  11. Experimental study on air cleaning effect of clean air heat pump and its impact on ventilation requirement

    DEFF Research Database (Denmark)

    Fang, Lei; Sheng, Ying; Nie, Jinzhe

    2017-01-01

    This study investigated air purification effect of a Clean-Air Heat Pump (CAHP) which combined a desiccant wheel with a heat pump for both air cleaning and HVAC of buildings. The experiment was conducted in a field lab at four different outdoor air supply rates with and without air cleaning by CAHP....... Both sensory assessments of perceived air quality and chemical measurements of TVOC concentrations were conducted for evaluating the air cleaning performance of the CAHP. The results of experiment showed that running the CAHP improved significantly perceived air quality. At 2 L/s per person of outdoor...... air supply rate with operating the CAHP, the air quality was equivalent to the value at the higher outdoor air supply rate of 10 L/s per person without running CAHP. The TVOC measurements observed over 92% of efficiency on removal of indoor air VOCs and no VOCs accumulation on the desiccant wheel...

  12. Type Directed Partial Evaluation for Level-1 Shift and Reset

    Directory of Open Access Journals (Sweden)

    Danko Ilik

    2013-09-01

    Full Text Available We present an implementation in the Coq proof assistant of type directed partial evaluation (TDPE algorithms for call-by-name and call-by-value versions of shift and reset delimited control operators, and in presence of strong sum types. We prove that the algorithm transforms well-typed programs to ones in normal form. These normal forms can not always be arrived at using the so far known equational theories. The typing system does not allow answer-type modification for function types and allows delimiters to be set on at most one atomic type. The semantic domain for evaluation is expressed in Constructive Type Theory as a dependently typed monadic structure combining Kripke models and continuation passing style translations.

  13. The RESET Mindset Model applied on decreasing antibiotic usage in dairy cattle in the Netherlands.

    Science.gov (United States)

    Lam, T J G M; Jansen, J; Wessels, R J

    2017-01-01

    Prudent use of antibiotics is important to prevent antibiotic resistance in humans and in animals. For this reason politicians demanded a decrease of total antibiotic use and of use of critically important antibiotics in animal husbandry in the Netherlands. In the dairy sector the use of antibiotics almost halved in the years 2009-2015, with a decrease of the use of critically important antibiotics to very low levels. To realize a sustainable decrease in antibiotic usage, the mindset towards the subject was considered crucial. Based on several models from social psychology, the RESET Mindset Model was used. This model contains the most important cues to change human behaviour, being Rules and regulations, Education and information, Social pressure, Economics, and Tools. To change behaviour of groups in order to reach a tipping point, it is of utmost importance to not choose among the different cues, but to use them all. In order to decrease antibiotic usage in dairy cattle in the Netherlands several actions, obliged as well as voluntary, were undertaken. An independent veterinary medicine authority was founded that became active for all animal sectors. In the dairy sector a national database on antibiotic usage called MediRund was developed, which made transparency and benchmarking on antibiotic usage at the national and the herd level possible. Several other activities are described, such as herd health and treatment plans, selective dry cow therapy, and the strong limitation on the use of critically important antibiotics. Antibiotic usage at the herd level, referred to as the 'antibiotic number', became an important and socially accepted herd level parameter. The actions undertaken worked through different cues, all part of the RESET Mindset Model. As such, different types of dairy farmers sensitive to different types of cues were motivated to change their behaviour. Antibiotic usage in dairy cattle in the Netherlands decreased significantly by intense

  14. Research on the water hammer protection of the long distance water supply project with the combined action of the air vessel and over-pressure relief valve

    International Nuclear Information System (INIS)

    Li, D D; Jiang, J; Zhao, Z; Yi, W S; Lan, G

    2013-01-01

    We take a concrete pumping station as an example in this paper. Through the calculation of water hammer protection with a specific pumping station water supply project, and the analysis of the principle, mathematical models and boundary conditions of air vessel and over-pressure relief valve we show that the air vessel can protect the water conveyance system and reduce the transient pressure damage due to various causes. Over-pressure relief valve can effectively reduce the water hammer because the water column re-bridge suddenly stops the pump and prevents pipeline burst. The paper indicates that the combination set of air vessel and over-pressure relief valve can greatly reduce the quantity of the air valve and can eliminate the water hammer phenomenon in the pipeline system due to the vaporization and water column separation and re-bridge. The conclusion could provide a reference for the water hammer protection of long-distance water supply system

  15. Research on the water hammer protection of the long distance water supply project with the combined action of the air vessel and over-pressure relief valve

    Science.gov (United States)

    Li, D. D.; Jiang, J.; Zhao, Z.; Yi, W. S.; Lan, G.

    2013-12-01

    We take a concrete pumping station as an example in this paper. Through the calculation of water hammer protection with a specific pumping station water supply project, and the analysis of the principle, mathematical models and boundary conditions of air vessel and over-pressure relief valve we show that the air vessel can protect the water conveyance system and reduce the transient pressure damage due to various causes. Over-pressure relief valve can effectively reduce the water hammer because the water column re-bridge suddenly stops the pump and prevents pipeline burst. The paper indicates that the combination set of air vessel and over-pressure relief valve can greatly reduce the quantity of the air valve and can eliminate the water hammer phenomenon in the pipeline system due to the vaporization and water column separation and re-bridge. The conclusion could provide a reference for the water hammer protection of long-distance water supply system.

  16. Development of a Data-Driven Predictive Model of Supply Air Temperature in an Air-Handling Unit for Conserving Energy

    Directory of Open Access Journals (Sweden)

    Goopyo Hong

    2018-02-01

    Full Text Available The purpose of this study was to develop a data-driven predictive model that can predict the supply air temperature (SAT in an air-handling unit (AHU by using a neural network. A case study was selected, and AHU operational data from December 2015 to November 2016 was collected. A data-driven predictive model was generated through an evolving process that consisted of an initial model, an optimal model, and an adaptive model. In order to develop the optimal model, input variables, the number of neurons and hidden layers, and the period of the training data set were considered. Since AHU data changes over time, an adaptive model, which has the ability to actively cope with constantly changing data, was developed. This adaptive model determined the model with the lowest mean square error (MSE of the 91 models, which had two hidden layers and sets up a 12-hour test set at every prediction. The adaptive model used recently collected data as training data and utilized the sliding window technique rather than the accumulative data method. Furthermore, additional testing was performed to validate the adaptive model using AHU data from another building. The final adaptive model predicts SAT to a root mean square error (RMSE of less than 0.6 °C.

  17. Experimental analysis of indoor air quality improvement achieved by using a Clean-Air Heat Pump (CAHP) air-cleaner in a ventilation system

    DEFF Research Database (Denmark)

    Sheng, Ying; Fang, Lei; Nie, Jinzhe

    2017-01-01

    This study investigated the air purification effect of a Clean-Air Heat Pump (CAHP) air-cleaner which combined a silica gel rotor with a heat pump to achieve air cleaning, heating and ventilation in buildings. The experiments were conducted in a field laboratory and compared a low outdoor air...... supply rate with CAHP air purification of recirculated air with three different outdoor air supply rates without recirculation or air cleaning. Sensory assessments of perceived air quality and chemical measurements of TVOC concentration were used to evaluate the air-cleaning performance of the CAHP....... The results of the experiment showed that the operation of the CAHP significantly improved the perceived air quality in a room polluted by both human bio-effluents and building materials. At the outdoor airflow rate of 2 L/s per person, the indoor air quality with CAHP was equivalent to what was achieved...

  18. Comparison of the Performance of Chilled Beam with Swirl Jet and Diffuse Ceiling Air Supply: Impact of Heat Load Distribution

    DEFF Research Database (Denmark)

    Bertheussen, Bård; Mustakallio, Panu; Kosonen, Risto

    2013-01-01

    The impact of heat load strength and positioning on the indoor environment generated by diffuse ceiling air supply and chilled beam with radial swirl jet was studied and compared. An office room with two persons and a meeting room with six persons were simulated in a test room (4.5 x 3.95 x 3.5 m3......) and Category B thermal environment in the meeting room at high heat load of 94 W∙m−2. The air distribution pattern was influenced by the convective flows from the heat sources. The maximum local velocity in the occupied zone was 0.23–0.26 m∙s−1. The diffuse ceiling supply did not ensure complete mixing...... temperature was controlled at 24 °C. The quality of the generated indoor environment as defined in ISO standard 7730 (2005) was assessed based on comprehensive physical measurements. The systems created Category A thermal environment in cooling situations at heat load of 50 W∙m−2 and 78 W∙m−2 (office room...

  19. Safety-related control air systems

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    This Standard applies to those portions of the control air system that furnish air required to support, control, or operate systems or portions of systems that are safety related in nuclear power plants. This Standard relates only to the air supply system(s) for safety-related air operated devices and does not apply to the safety-related air operated device or to air operated actuators for such devices. The objectives of this Standard are to provide (1) minimum system design requirements for equipment, piping, instruments, controls, and wiring that constitute the air supply system; and (2) the system and component testing and maintenance requirements

  20. Optimisation of compressed-air supply for control purposes at Valorec Services AG; Optimierung der Steuerluft - Versorgung bei der Valorec Services AG

    Energy Technology Data Exchange (ETDEWEB)

    Dott, R.; Afjei, T.

    2005-07-01

    This final report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that looked at the possibilities of optimising the supply of compressed air provided around the clock by four compressor systems of varying ages in a facility in Basle, Switzerland. The initial situation is analysed and the potential for making savings is estimated. Various possibilities for improvement are considered including changing the topology of the compressed-air network, the replacement of certain compressors and a new control system. Appropriate measures are proposed and compared with new installations.

  1. Melanopsin resets circadian rhythms in cells by inducing clock gene Period1

    Science.gov (United States)

    Yamashita, Shuhei; Uehara, Tomoe; Matsuo, Minako; Kikuchi, Yo; Numano, Rika

    2014-02-01

    The biochemical, physiological and behavioral processes are under the control of internal clocks with the period of approximately 24 hr, circadian rhythms. The expression of clock gene Period1 (Per1) oscillates autonomously in cells and is induced immediately after a light pulse. Per1 is an indispensable member of the central clock system to maintain the autonomous oscillator and synchronize environmental light cycle. Per1 expression could be detected by Per1∷luc and Per1∷GFP plasmid DNA in which firefly luciferase and Green Fluorescence Protein were rhythmically expressed under the control of the mouse Per1 promoter in order to monitor mammalian circadian rhythms. Membrane protein, MELANOPSIN is activated by blue light in the morning on the retina and lead to signals transduction to induce Per1 expression and to reset the phase of circadian rhythms. In this report Per1 induction was measured by reporter signal assay in Per1∷luc and Per1∷GFP fibroblast cell at the input process of circadian rhythms. To the result all process to reset the rhythms by Melanopsin is completed in single cell like in the retina projected to the central clock in the brain. Moreover, the phase of circadian rhythm in Per1∷luc cells is synchronized by photo-activated Melanopsin, because the definite peak of luciferase activity in one dish was found one day after light illumination. That is an available means that physiological circadian rhythms could be real-time monitor as calculable reporter (bioluminescent and fluorescent) chronological signal in both single and groups of cells.

  2. Boundary conditions for natural supply ventilation

    NARCIS (Netherlands)

    Jansen, D.W.L.; Loomans, M.G.L.C.; Wit, de M.H.; Zeiler, W.; Seppänen, O.; Säteri, J.

    2007-01-01

    The development of an air jet from a controlled natural ventilation grill for different outdoor conditions is studied. Extensive laboratory measurements are taken in different situations, while the air flow rate through the grill is kept constant. The grill setting and supply temperature are varied.

  3. Strategy Guideline: Compact Air Distribution Systems

    Energy Technology Data Exchange (ETDEWEB)

    Burdick, A.

    2013-06-01

    This Strategy Guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. Traditional systems sized by 'rule of thumb' (i.e., 1 ton of cooling per 400 ft2 of floor space) that 'wash' the exterior walls with conditioned air from floor registers cannot provide appropriate air mixing and moisture removal in low-load homes. A compact air distribution system locates the HVAC equipment centrally with shorter ducts run to interior walls, and ceiling supply outlets throw the air toward the exterior walls along the ceiling plane; alternatively, high sidewall supply outlets throw the air toward the exterior walls. Potential drawbacks include resistance from installing contractors or code officials who are unfamiliar with compact air distribution systems, as well as a lack of availability of low-cost high sidewall or ceiling supply outlets to meet the low air volumes with good throw characteristics. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

  4. Improvement in R{sub off}/R{sub on} ratio and reset current via combining compliance current with multilayer structure in tantalum oxide-based RRAM

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Xiaorong; Feng, Jie [Shanghai Jiao Tong University, Key Laboratory for Thin Film and Microfabrication of Ministry of Education, Department of Micro/Nano Electronics, Shanghai (China)

    2015-07-15

    Improvements in the R{sub off}/R{sub on} ratio and reset current are required prior to the practical application of RRAM. To achieve this improvement, tantalum oxide-based RRAM devices with multilayer structure (bi-layer and tri-layer) were fabricated and various compliance currents were adopted. The reset current of 40 μA was observed; the R{sub off}/R{sub on} ratio increased to more than 20 in the tri-layer structure device. Resistance changes in two types of devices under voltage pulses with different pulse width were also conducted. The tri-layer device exhibited lower reset voltage and higher R{sub off}/R{sub on} ratio than the bi-layer device under voltage pulses. X-ray photoelectron spectroscopy demonstrated the formation of Ta{sub 2}O{sub 5} via plasma oxidation, and there was an oxygen gradient in the multilayer devices. The results demonstrated that the tri-layer structure with oxygen gradient was an effective method for achieving better device performance. Additionally, it is implied that reasonable control of the proportion of TaO{sub 2} and Ta{sub 2}O{sub 5} and compliance current can improve device performance. (orig.)

  5. 40 CFR 89.326 - Engine intake air humidity measurement.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Engine intake air humidity measurement... Test Equipment Provisions § 89.326 Engine intake air humidity measurement. (a) Humidity conditioned air... type of intake air supply, the humidity measurements must be made within the intake air supply system...

  6. 40 CFR 91.310 - Engine intake air humidity measurement.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Engine intake air humidity measurement... Provisions § 91.310 Engine intake air humidity measurement. This section refers to engines which are supplied... air, the ambient testcell humidity measurement may be used. (a) Humidity conditioned air supply. Air...

  7. Air ventilation/controlling facility

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Kazuhiro; Kinoshita, Shoichiro

    1997-12-12

    When all electricity supply from the outside of a power plant are lost, a power generator directly connected to an emergency steam turbine which is driven by steams introduced from a nuclear reactor is driven to supply electricity required in the power plant. Cool water prepared by a refrigerator is used as cooling water in an air ventilation/controlling facility of a room equipped with the power generating facility. As the refrigerator, a refrigerator of an existent emergency air cooling water system for an auxiliary air ventilation/controlling equipment is used. This can extend the period of time till the temperature of the room where the power generator is disposed exceeds the temperature range capable of keeping the integrity of the power generator even when all the AC power supply are lost to inactivate the function of the air ventilation/controlling system. (I.S.)

  8. Respirator studies for the Nuclear Regulatory Commission. Protection factors for supplied-air respirators. Progress report, October 1, 1976--September 30, 1977

    International Nuclear Information System (INIS)

    Hack, A.; Bradley, O.D.; Trujillo, A.

    1977-12-01

    This report describes the work performed during FY 1977 for the Nuclear Regulatory Commission. The Protection Factors (efficiency) provided by 25 NIOSH approved supplied-air respirators were determined while the devices were worn by a panel of anthropometrically selected test subjects. The major recommendation was that demand-type respirators should neither be used nor approved

  9. Defense Logistics: Army and Marine Corps Cannot Be Assured That Equipment Reset Strategies Will Sustain Equipment Availability While Meeting Ongoing Operational Requirements

    National Research Council Canada - National Science Library

    Solis, William M; Schmitt, David A; Brown, Renee; Cristinzio, Frank; Hartig, Luke; Helt, Brent; Rogers, Donna M; Song, Yong; Storts, Maria

    2007-01-01

    .... Because of the potential for equipment reset costs to affect the Department of Defense's (DoD) future budget requirements and related readiness concerns, GAO initiated this review under the Comptroller General's authority...

  10. Air filtration and indoor air quality

    DEFF Research Database (Denmark)

    Bekö, Gabriel

    2006-01-01

    Demands for better indoor air quality are increasing, since we spend most of our time indoors and we are more and more aware of indoor air pollution. Field studies in different parts of the world have documented that high percentage of occupants in many offices and buildings find the indoor air...... decent ventilation and air cleaning/air filtration, high indoor air quality cannot be accomplished. The need for effective air filtration has increased with increasing evidence on the hazardous effects of fine particles. Moreover, the air contains gaseous pollutants, removal of which requires various air...... cleaning techniques. Supply air filter is one of the key components in the ventilation system. Studies have shown that used ventilation filters themselves can be a significant source of indoor air pollution with consequent impact on perceived air quality, sick building syndrome symptoms and performance...

  11. Direct Digital Control Study.

    Science.gov (United States)

    1985-02-01

    Deck - Cold Deck Reset Reheat Coil Reset Steam Boiler Optimization [lot Water Outside Air Reset Chiller Optimization Chiller Water Temperature Reset...with programming techniques for each type of installed DDC in order to effect changes in operating setpoints and application programs. *Communication...can be changed without recailbration of instrumentation devices. Changes to the application software, operating setpoints and parameters require the

  12. Learning of temporal motor patterns: An analysis of continuous vs. reset timing

    Directory of Open Access Journals (Sweden)

    Rodrigo eLaje

    2011-10-01

    Full Text Available Our ability to generate well-timed sequences of movements is critical to an array of behaviors, including the ability to play a musical instrument or a video game. Here we address two questions relating to timing with the goal of better understanding the neural mechanisms underlying temporal processing. First, how does accuracy and variance change over the course of learning of complex spatiotemporal patterns? Second, is the timing of sequential responses most consistent with starting and stopping an internal timer at each interval or with continuous timing?To address these questions we used a psychophysical task in which subjects learned to reproduce a sequence of finger taps in the correct order and at the correct times—much like playing a melody at the piano. This task allowed us to calculate the variance of the responses at different time points using data from the same trials. Our results show that while standard Weber’s law is clearly violated, variance does increase as a function of time squared, as expected according to the generalized form of Weber’s law—which separates the source of variance into time-dependent and time-independent components. Over the course of learning, both the time-independent variance and the coefficient of the time-dependent term decrease. Our analyses also suggest that timing of sequential events does not rely on the resetting of an internal timer at each event.We describe and interpret our results in the context of computer simulations that capture some of our psychophysical findings. Specifically, we show that continuous timing, as opposed to reset timing, is expected from population clock models in which timing emerges from the internal dynamics of recurrent neural networks.

  13. Study on the Development of an Optimal Heat Supply Control Algorithm for Group Energy Apartment Buildings According to the Variation of Outdoor Air Temperature

    Directory of Open Access Journals (Sweden)

    Dong-Kurl Kwak

    2012-05-01

    Full Text Available In the present study, we have developed an optimal heat supply algorithm which minimizes the heat loss through the distribution pipe line in a group energy apartment. Heating load variation of a group energy apartment building according to the outdoor air temperature was predicted by a correlation obtained from calorimetry measurements of all households in the apartment building. Supply water temperature and mass flow rate were simultaneously controlled to minimize the heat loss rate through the distribution pipe line. A group heating apartment building located in Hwaseong city, Korea, which has 1473 households, was selected as the object building to test the present heat supply algorithm. Compared to the original heat supply system, the present system adopting the proposed control algorithm reduced the heat loss rate by 10.4%.

  14. Improved airline-type supplied-air plastic suit. [For personnel protection against inhalation of airborne plutonium and tritium

    Energy Technology Data Exchange (ETDEWEB)

    Jolley, L. Jr.; Zippler, D.B.; Cofer, C.H.; Harper, J.A.

    1978-06-01

    Two piece supplied-air plastic suits are used extensively at the Savannah River Plant for personnel protection against inhalation of airborne plutonium and tritium. Worker comfort and noise level problems gave impetus to development of an improved suit and aid distribution system. The resulting plastic suit and development work are discussed. The plastic suit unit cost is less than $20, the hearing zone noise level is less than 75 dBA, protection factors exceed 10,000, and user comfort is approved. This suit is expected to meet performance requirements for unrestricted use.

  15. 42 CFR 84.162 - Man test for gases and vapors; Type C respirators, continuous-flow class and Type CE supplied-air...

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Man test for gases and vapors; Type C respirators, continuous-flow class and Type CE supplied-air respirators; test requirements. 84.162 Section 84.162 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL...

  16. Simulation of thermal reset transitions in resistive switching memories including quantum effects

    Energy Technology Data Exchange (ETDEWEB)

    Villena, M. A.; Jiménez-Molinos, F.; Roldán, J. B. [Departamento de Electrónica y Tecnología de Computadores, Universidad de Granada, Facultad de Ciencias, Avd. Fuentenueva s/n, 18071 Granada (Spain); González, M. B.; Campabadal, F. [Institut de Microelectrònica de Barcelona, IMB-CNM (CSIC), Campus UAB, 08193 Bellaterra (Spain); Suñé, J.; Miranda, E. [Departament d' Enginyeria Electrònica, Universitat Autònoma de Barcelona, Bellaterra Cerdanyola del Vallès 08193 (Spain); Romera, E. [Departamento de Física Atómica, Molecular y Nuclear and Instituto Carlos I de Física Teórica y Computacional, Universidad de Granada, Avd. Fuentenueva s/n, 18071 Granada (Spain)

    2014-06-07

    An in-depth study of reset processes in RRAMs (Resistive Random Access Memories) based on Ni/HfO{sub 2}/Si-n{sup +} structures has been performed. To do so, we have developed a physically based simulator where both ohmic and tunneling based conduction regimes are considered along with the thermal description of the devices. The devices under study have been successfully fabricated and measured. The experimental data are correctly reproduced with the simulator for devices with a single conductive filament as well as for devices including several conductive filaments. The contribution of each conduction regime has been explained as well as the operation regimes where these ohmic and tunneling conduction processes dominate.

  17. Tasimelteon for non-24-hour sleep-wake disorder in totally blind people (SET and RESET): two multicentre, randomised, double-masked, placebo-controlled phase 3 trials.

    Science.gov (United States)

    Lockley, Steven W; Dressman, Marlene A; Licamele, Louis; Xiao, Changfu; Fisher, Dennis M; Flynn-Evans, Erin E; Hull, Joseph T; Torres, Rosarelis; Lavedan, Christian; Polymeropoulos, Mihael H

    2015-10-31

    Most totally blind people have non-24-hour sleep-wake disorder (non-24), a rare circadian rhythm disorder caused by an inability of light to reset their circadian pacemaker. In two consecutive placebo-controlled trials (SET and RESET), we assessed safety and efficacy (in terms of circadian entrainment and maintenance) of once-daily tasimelteon, a novel dual-melatonin receptor agonist. We undertook the placebo-controlled, randomised, double-masked trials in 27 US and six German clinical research centres and sleep centres. We screened totally blind adults (18-75 years of age), who were eligible for the randomisation phase of SET if they had a non-24-hour circadian period (τ) of 24·25 h or longer (95% CI greater than 24·0 and up to 24·9 h), as calculated from measurements of urinary 6-sulphatoxymelatonin rhythms. For SET, we used block randomisation to assign patients (1:1) to receive tasimelteon (20 mg) or placebo every 24 h at a fixed clock time 1 h before target bedtime for 26 weeks. Patients who entered the open-label group receiving tasimelteon in SET or who did not meet the SET inclusion criteria but did meet the RESET inclusion criteria were screened for RESET. A subset of the patients who entered the open-label group before the RESET study and who had eligible τ values were screened for RESET after completing the open-label treatment. In RESET, we withdrew tasimelteon in a randomised manner (1:1) in patients who responded (ie, entrained) after a tasimelteon run-in period. Entrainment was defined as having τ of 24·1 h or less and a 95% CI that included 24·0 h. In SET, the primary endpoint was the proportion of entrained patients, assessed in the intention-to-treat population. The planned step-down primary endpoint assessed the proportion of patients who had a clinical response (entrainment at month 1 or month 7 plus clinical improvement, measured by the Non-24 Clinical Response Scale). In RESET, the primary endpoint was the proportion of non

  18. Resetting the evolution of marine reptiles at the Triassic-Jurassic boundary.

    Science.gov (United States)

    Thorne, Philippa M; Ruta, Marcello; Benton, Michael J

    2011-05-17

    Ichthyosaurs were important marine predators in the Early Jurassic, and an abundant and diverse component of Mesozoic marine ecosystems. Despite their ecological importance, however, the Early Jurassic species represent a reduced remnant of their former significance in the Triassic. Ichthyosaurs passed through an evolutionary bottleneck at, or close to, the Triassic-Jurassic boundary, which reduced their diversity to as few as three or four lineages. Diversity bounced back to some extent in the aftermath of the end-Triassic mass extinction, but disparity remained at less than one-tenth of pre-extinction levels, and never recovered. The group remained at low diversity and disparity for its final 100 Myr. The end-Triassic mass extinction had a previously unsuspected profound effect in resetting the evolution of apex marine predators of the Mesozoic.

  19. Effect of efficient supply of pure O{sub 2} concentrated by PSA-type O{sub 2} separator on improvement of indoor air quality

    Energy Technology Data Exchange (ETDEWEB)

    Han, Gi Bo; Jang, Jung Hee; Choi, Changsik [Institute for Advanced Engineering, Yongin (Korea, Republic of); Lee, Tae Jin [School of Chemical Engineering Yeungnam University, Gyeongsan (Korea, Republic of)

    2016-04-15

    To minimize the cost and loss rate of energy artificial room ventilation system, the O{sub 2} separator was suggested for the flow of the excessive ventilation amount between indoor and outdoor because the pure O{sub 2} separated and concentrated by the O{sub 2} separator can be supplied with the ventilation amount minimized. How the O{sub 2} separator applies to ventilation and its operation characteristics were investigated by controlling under various conditions as well as the operation conditions optimized required for indoor air quality such as the concentration of CO{sub 2} and O{sub 2}. Consequently, it was known that the O{sub 2} concentration was increased; however, the increase of the CO{sub 2} concentration was suppressed by the sufficient supply of O{sub 2} concentrated from the storage tank into the room despite the two persons’ breathing in the room having an inner volume of about 56m{sup 3}. Consequently, it was concluded that the supply system of the concentrated O{sub 2} which was stored into the tank after the production with the O{sub 2} separator can be applied to the room ventilation system for the improvement of the indoor air quality.

  20. Impact of individually controlled facially applied air movement on perceived air quality at high humidity

    DEFF Research Database (Denmark)

    Skwarczynski, Mariusz; Melikov, Arsen Krikor; Kaczmarczyk, J.

    2010-01-01

    and local air velocity under a constant air temperature of 26 degrees C, namely: 70% relative humidity without air movement, 30% relative humidity without air movement and 70% relative humidity with air movement under isothermal conditions. Personalized ventilation was used to supply room air from the front...

  1. Design and development of a low cost, high current density power supply for streamer free atmospheric pressure DBD plasma generation in air.

    Science.gov (United States)

    Jain, Vishal; Visani, Anand; Srinivasan, R; Agarwal, Vivek

    2018-03-01

    This paper presents a new power supply architecture for generating a uniform dielectric barrier discharge (DBD) plasma in air medium at atmospheric pressure. It is quite a challenge to generate atmospheric pressure uniform glow discharge plasma, especially in air. This is because air plasma needs very high voltage for initiation of discharge. If the high voltage is used along with high current density, it leads to the formation of streamers, which is undesirable for most applications like textile treatment, etc. Researchers have tried to generate high-density plasma using a RF source, nanosecond pulsed DC source, and medium frequency AC source. However, these solutions suffer from low current discharge and low efficiency due to the addition of an external resistor to control the discharge current. Moreover, they are relatively costly and bulky. This paper presents a new power supply configuration which is very compact and generates high average density (∼0.28 W/cm 2 ) uniform glow DBD plasma in air at atmospheric pressure. The efficiency is also higher as no external resistor is required to control the discharge current. An inherent feature of this topology is that it can drive higher current oscillations (∼50 A peak and 2-3 MHz frequency) into the plasma that damp out due to the plasma dissipation only. A newly proposed model has been used with experimental validation in this paper. Simulations and experimental validation of the proposed topology are included. Also, the application of the generated plasma for polymer film treatment is demonstrated.

  2. Optimal number of stimulation contacts for coordinated reset neuromodulation

    Directory of Open Access Journals (Sweden)

    Borys eLysyansky

    2013-07-01

    Full Text Available In this computational study we investigatecoordinated reset (CR neuromodulation designed for an effective controlof synchronization by multi-site stimulation of neuronal target populations. This method was suggested to effectively counteract pathological neuronal synchronycharacteristic for several neurological disorders. We studyhow many stimulation sites are required for optimal CR-induced desynchronization. We found that a moderate increase of the number of stimulation sitesmay significantly prolong the post-stimulation desynchronized transientafter the stimulation is completely switched off. This can, in turn,reduce the amount of the administered stimulation current for theintermittent ON-OFF CR stimulation protocol, where time intervalswith stimulation ON are recurrently followed by time intervals withstimulation OFF. In addition, we found that the optimal number ofstimulation sites essentially depends on how strongly the administeredcurrent decays within the neuronal tissue with increasing distancefrom the stimulation site. In particular, for a broad spatial stimulationprofile, i.e., for a weak spatial decay rate of the stimulation current,CR stimulation can optimally be delivered via a small number of stimulationsites. Our findings may contribute to an optimization of therapeutic applications of CR neuromodulation.

  3. Impact of individually controlled facially applied air movement on perceived air quality at high humidity

    Energy Technology Data Exchange (ETDEWEB)

    Skwarczynski, M.A. [Faculty of Environmental Engineering, Institute of Environmental Protection Engineering, Department of Indoor Environment Engineering, Lublin University of Technology, Lublin (Poland); International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Copenhagen (Denmark); Melikov, A.K.; Lyubenova, V. [International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark, Copenhagen (Denmark); Kaczmarczyk, J. [Faculty of Energy and Environmental Engineering, Department of Heating, Ventilation and Dust Removal Technology, Silesian University of Technology, Gliwice (Poland)

    2010-10-15

    The effect of facially applied air movement on perceived air quality (PAQ) at high humidity was studied. Thirty subjects (21 males and 9 females) participated in three, 3-h experiments performed in a climate chamber. The experimental conditions covered three combinations of relative humidity and local air velocity under a constant air temperature of 26 C, namely: 70% relative humidity without air movement, 30% relative humidity without air movement and 70% relative humidity with air movement under isothermal conditions. Personalized ventilation was used to supply room air from the front toward the upper part of the body (upper chest, head). The subjects could control the flow rate (velocity) of the supplied air in the vicinity of their bodies. The results indicate an airflow with elevated velocity applied to the face significantly improves the acceptability of the air quality at the room air temperature of 26 C and relative humidity of 70%. (author)

  4. Sensitivity of the human circadian pacemaker to nocturnal light: melatonin phase resetting and suppression

    Science.gov (United States)

    Zeitzer, J. M.; Dijk, D. J.; Kronauer, R.; Brown, E.; Czeisler, C.

    2000-01-01

    Ocular exposure to early morning room light can significantly advance the timing of the human circadian pacemaker. The resetting response to such light has a non-linear relationship to illuminance. The dose-response relationship of the human circadian pacemaker to late evening light of dim to moderate intensity has not been well established. Twenty-three healthy young male and female volunteers took part in a 9 day protocol in which a single experimental light exposure6.5 h in duration was given in the early biological night. The effects of the light exposure on the endogenous circadian phase of the melatonin rhythm and the acute effects of the light exposure on plasma melatonin concentration were calculated. We demonstrate that humans are highly responsive to the phase-delaying effects of light during the early biological night and that both the phase resetting response to light and the acute suppressive effects of light on plasma melatonin follow a logistic dose-response curve, as do many circadian responses to light in mammals. Contrary to expectations, we found that half of the maximal phase-delaying response achieved in response to a single episode of evening bright light ( approximately 9000 lux (lx)) can be obtained with just over 1 % of this light (dim room light of approximately 100 lx). The same held true for the acute suppressive effects of light on plasma melatonin concentrations. This indicates that even small changes in ordinary light exposure during the late evening hours can significantly affect both plasma melatonin concentrations and the entrained phase of the human circadian pacemaker.

  5. The effects of electrostatic particle filtration and supply-air filter condition in classrooms on the performance of schoolwork by children (RP-1257)

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Wyon, David Peter; Jensen, Kasper Lynge

    2008-01-01

    the lower the outdoor air supply rate. There were no consistent effects of this reduction on the performance of schoolwork, on the children's perception of the classroom environment, on symptom intensiiy, or on air quality as perceived by the sensory panel. This suggests there are no short-term (acute...... the filters in use in other schools were not changed. The conditions were established for one week at a time in a blind crossover design with repeated measures on ten-to-twelve-year-old children. Pupils performed six exercises exemplifying different aspects of schoolwork as part of normal lessons...... and indicated their environmental perceptions and the intensity of any symptoms. A sensory panel of adults judged the air quality in the classrooms soon after the pupils left. Operating the electrostatic air cleaners considerably reduced the concentration of particles in the classrooms. The effect was greater...

  6. Long-lasting desynchronization in rat hippocampal slice induced by coordinated reset stimulation

    International Nuclear Information System (INIS)

    Tass, P. A.; Barnikol, U. B.; Silchenko, A. N.; Hauptmann, C.; Speckmann, E.-J.

    2009-01-01

    In computational models it has been shown that appropriate stimulation protocols may reshape the connectivity pattern of neural or oscillator networks with synaptic plasticity in a way that the network learns or unlearns strong synchronization. The underlying mechanism is that a network is shifted from one attractor to another, so that long-lasting stimulation effects are caused which persist after the cessation of stimulation. Here we study long-lasting effects of multisite electrical stimulation in a rat hippocampal slice rendered epileptic by magnesium withdrawal. We show that desynchronizing coordinated reset stimulation causes a long-lasting desynchronization between hippocampal neuronal populations together with a widespread decrease in the amplitude of the epileptiform activity. In contrast, periodic stimulation induces a long-lasting increase in both synchronization and amplitude.

  7. Characterization and modeling of SET/RESET cycling induced read-disturb failure time degradation in a resistive switching memory

    Science.gov (United States)

    Su, Po-Cheng; Hsu, Chun-Chi; Du, Sin-I.; Wang, Tahui

    2017-12-01

    Read operation induced disturbance in SET-state in a tungsten oxide resistive switching memory is investigated. We observe that the reduction of oxygen vacancy density during read-disturb follows power-law dependence on cumulative read-disturb time. Our study shows that the SET-state read-disturb immunity progressively degrades by orders of magnitude as SET/RESET cycle number increases. To explore the cause of the read-disturb degradation, we perform a constant voltage stress to emulate high-field stress effects in SET/RESET cycling. We find that the read-disturb failure time degradation is attributed to high-field stress-generated oxide traps. Since the stress-generated traps may substitute for some of oxygen vacancies in forming conductive percolation paths in a switching dielectric, a stressed cell has a reduced oxygen vacancy density in SET-state, which in turn results in a shorter read-disturb failure time. We develop an analytical read-disturb degradation model including both cycling induced oxide trap creation and read-disturb induced oxygen vacancy reduction. Our model can well reproduce the measured read-disturb failure time degradation in a cycled cell without using fitting parameters.

  8. Double-diffusive mixed convection in the slot ventilated enclosure with different arrangements of supplying air flow ports

    Directory of Open Access Journals (Sweden)

    Heng-Sheng Cheng

    2015-03-01

    Full Text Available Steady double-diffusive mixed convection in an enclosure with side venting and discrete heat and contaminant sources is numerically studied under supplying upside and returning downside (STRB mode and returning upside and supplying downside mode (RTSB, respectively. The parameters governing the fluid flow include the Grashof number Gr (102–106, Reynolds number Re (100–500, supplying or returning distance H 1/HT (0–2, Prandtl number Pr (0.7, buoyancy ratio N, and Schmidt number Sc. Effects of Gr, Re, and H 1/HT on the flow patterns, thermal, and species transports were numerically investigated concerning STRB and RTSB modes. Fluid flow, heat, and species transports in the enclosure are visualized and analyzed by the contours of stream function, heat function, and mass function, respectively. Air age was also presented to evaluate the freshness of the enclosed fluid. Averaged Nusselt number of the heat source and Sherwood number of the contaminant source are power-law correlated with Gr, Re, and H 1/HT for two ventilation modes, respectively. The correlations demonstrate that the ratio of averaged Nusselt number to Sherwood number was approximately approaching unity, independent of ventilation modes and values of H 1/HT . This investigation could benefit the future design of room ventilation and thermal removals from the electronic chips.

  9. Safety-related control air systems - approved 1977

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    This standard applies to those portions of the control air system that furnish air required to support, control, or operate systems or portions of systems that are safety related in nuclear power plants. This standard relates only to the air supply system(s) for safety-related air operated devices and does not apply to the safety-related air operated device or to air operated actuators for such devices. The objectives of this standard are to provide (1) minimum system design requirements for equipment, piping, instruments, controls, and wiring that constitute the air supply system; and (2) the system and component testing and maintenance requirements

  10. The Foreign Policy of Modern China: from the Utopia of Nonpolar World to Chinese Reset

    Directory of Open Access Journals (Sweden)

    К И Аксёнова

    2012-03-01

    Full Text Available The author touches the strategic problem of building China's foreign policy, which in a multipolar world will soon make the country do its significative choice and find an opportunity of modernization. Successful exit strategy from the financial crisis has played a low-down trick with Beijing - the «donor of capital» image raised fears among the leading powers. So, the future of China's foreign policy will depend largely on its ability to transition to a more dynamic and flexible response to rapidly changing trends - the «reset».

  11. U.S. Air Force Operational Medicine: Using the Enterprise Estimating Supplies Program to Develop Materiel Solutions for the Aeromedical Evacuation In-Flight Kit (FFQDM)

    Science.gov (United States)

    2011-05-04

    HEMORRHAGE 1 533.10 ACUTE PEPTIC ULCER WITH PERFORATION 1 346.90 MIGRAINE UNPSECIFIED 1 410.90 ACUTE MYOCARDIAL INFARCTION OF UNSPECIFIED SITE 1 451.90...Enterprise Estimating Supplies Program (EESP), for the development and management of Air Force medical Allowance Standards as a baseline for

  12. Macroscopic phase-resetting curves for spiking neural networks

    Science.gov (United States)

    Dumont, Grégory; Ermentrout, G. Bard; Gutkin, Boris

    2017-10-01

    The study of brain rhythms is an open-ended, and challenging, subject of interest in neuroscience. One of the best tools for the understanding of oscillations at the single neuron level is the phase-resetting curve (PRC). Synchronization in networks of neurons, effects of noise on the rhythms, effects of transient stimuli on the ongoing rhythmic activity, and many other features can be understood by the PRC. However, most macroscopic brain rhythms are generated by large populations of neurons, and so far it has been unclear how the PRC formulation can be extended to these more common rhythms. In this paper, we describe a framework to determine a macroscopic PRC (mPRC) for a network of spiking excitatory and inhibitory neurons that generate a macroscopic rhythm. We take advantage of a thermodynamic approach combined with a reduction method to simplify the network description to a small number of ordinary differential equations. From this simplified but exact reduction, we can compute the mPRC via the standard adjoint method. Our theoretical findings are illustrated with and supported by numerical simulations of the full spiking network. Notably our mPRC framework allows us to predict the difference between effects of transient inputs to the excitatory versus the inhibitory neurons in the network.

  13. Macroscopic phase-resetting curves for spiking neural networks.

    Science.gov (United States)

    Dumont, Grégory; Ermentrout, G Bard; Gutkin, Boris

    2017-10-01

    The study of brain rhythms is an open-ended, and challenging, subject of interest in neuroscience. One of the best tools for the understanding of oscillations at the single neuron level is the phase-resetting curve (PRC). Synchronization in networks of neurons, effects of noise on the rhythms, effects of transient stimuli on the ongoing rhythmic activity, and many other features can be understood by the PRC. However, most macroscopic brain rhythms are generated by large populations of neurons, and so far it has been unclear how the PRC formulation can be extended to these more common rhythms. In this paper, we describe a framework to determine a macroscopic PRC (mPRC) for a network of spiking excitatory and inhibitory neurons that generate a macroscopic rhythm. We take advantage of a thermodynamic approach combined with a reduction method to simplify the network description to a small number of ordinary differential equations. From this simplified but exact reduction, we can compute the mPRC via the standard adjoint method. Our theoretical findings are illustrated with and supported by numerical simulations of the full spiking network. Notably our mPRC framework allows us to predict the difference between effects of transient inputs to the excitatory versus the inhibitory neurons in the network.

  14. Improving Energy Security for Air Force Installations

    Science.gov (United States)

    Schill, David

    Like civilian infrastructure, Air Force installations are dependent on electrical energy for daily operations. Energy shortages translate to decreased productivity, higher costs, and increased health risks. But for the United States military, energy shortages have the potential to become national security risks. Over ninety-five percent of the electrical energy used by the Air Force is supplied by the domestic grid, which is susceptible to shortages and disruptions. Many Air Force operations require a continuous source of energy, and while the Air Force has historically established redundant supplies of electrical energy, these back-ups are designed for short-term outages and may not provide sufficient supply for a longer, sustained power outage. Furthermore, it is the goal of the Department of Defense to produce or procure 25 percent of its facility energy from renewable sources by fiscal year 2025. In a government budget environment where decision makers are required to provide more capability with less money, it is becoming increasingly important for informed decisions regarding which energy supply options bear the most benefit for an installation. The analysis begins by exploring the field of energy supply options available to an Air Force installation. The supply options are assessed according to their ability to provide continuous and reliable energy, their applicability to unique requirements of Air Force installations, and their costs. Various methods of calculating energy usage by an installation are also addressed. The next step of this research develops a methodology and tool which assesses how an installation responds to various power outage scenarios. Lastly, various energy supply options are applied to the tool, and the results are reported in terms of cost and loss of installation capability. This approach will allow installation commanders and energy managers the ability to evaluate the cost and effectiveness of various energy investment options.

  15. The effect of a personalized ventilation system on perceived air quality and SBS symptoms

    DEFF Research Database (Denmark)

    Kaczmarczyk, Jan; Zeng, Q.; Melikov, Arsen Krikor

    2002-01-01

    Perceived air quality, SBS symptoms and performance were studied with 30 human subjects. Experiments were performed in an office set-up with six workplaces, each equipped with a Personalized Ventilation System (PVS). Each PVS allowed the amount of supply air and its direction to be controlled...... condition in regard to perceived air quality, perception of freshness and intensity of SBS symptoms was when PVS supplied outdoor air at 20 deg.C. Perceived air quality in this case was significantly better (p....... Subjects participated in four experiments: (1) PVS supplying outdoor air at 20 deg.C; (2) PVS supplying outdoor air at 23 deg.C; (3) PVS supplying recirculated room air; and (4) mixing ventilation. Room temperature was kept constant at 23 deg.C and relative humidity at 30%. Results showed that the best...

  16. The "Family Tree" of Air Distribution Systems

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    2011-01-01

    In this paper all total volume air distribution principles are addressed based on discussions of air flow pattern in a room with heat sources giving a cooling load. The supply and exhaust air openings are considered to have different locations and sizes in the room, and it is possible to show tha...... conditions which are not used for air distribution in general. A number of experiments with different air distribution systems are addressed, and they illustrate the behaviour at the different conditions discussed in the paper....... that all the known types of air distribution systems are interconnected in a “family tree”. The influence of supplied momentum flow versus buoyancy forces is discussed, and geometries for high ventilation effectiveness are indicated as well as geometries for fully mixed flow. The paper will also show......In this paper all total volume air distribution principles are addressed based on discussions of air flow pattern in a room with heat sources giving a cooling load. The supply and exhaust air openings are considered to have different locations and sizes in the room, and it is possible to show...

  17. Concatenated logic circuits based on a three-way DNA junction: a keypad-lock security system with visible readout and an automatic reset function.

    Science.gov (United States)

    Chen, Junhua; Zhou, Shungui; Wen, Junlin

    2015-01-07

    Concatenated logic circuits operating as a biocomputing keypad-lock security system with an automatic reset function have been successfully constructed on the basis of toehold-mediated strand displacement and three-way-DNA-junction architecture. In comparison with previously reported keypad locks, the distinctive advantage of the proposed security system is that it can be reset and cycled spontaneously a large number of times without an external stimulus, thus making practical applications possible. By the use of a split-G-quadruplex DNAzyme as the signal reporter, the output of the keypad lock can be recognized readily by the naked eye. The "lock" is opened only when the inputs are introduced in an exact order. This requirement provides defense against illegal invasion to protect information at the molecular scale. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Warfighter Support: Army Has Taken Steps to Improve Reset Process, but More Complete Reporting of Equipment and Future Cost Is Needed

    Science.gov (United States)

    2012-05-01

    asphalt spreaders ), other semi-trucks and trailers, palletized loading systems, and heavy equipment transports. As table 3 shows, the actual reset...Copies of GAO Reports and Testimony Order by Phone Connect with GAO To Report Fraud, Waste, and Abuse in Federal Programs Congressional Relations Public Affairs Please Print on Recycled Paper.

  19. Optimal number of stimulation contacts for coordinated reset neuromodulation

    Science.gov (United States)

    Lysyansky, Borys; Popovych, Oleksandr V.; Tass, Peter A.

    2013-01-01

    In this computational study we investigate coordinated reset (CR) neuromodulation designed for an effective control of synchronization by multi-site stimulation of neuronal target populations. This method was suggested to effectively counteract pathological neuronal synchrony characteristic for several neurological disorders. We study how many stimulation sites are required for optimal CR-induced desynchronization. We found that a moderate increase of the number of stimulation sites may significantly prolong the post-stimulation desynchronized transient after the stimulation is completely switched off. This can, in turn, reduce the amount of the administered stimulation current for the intermittent ON–OFF CR stimulation protocol, where time intervals with stimulation ON are recurrently followed by time intervals with stimulation OFF. In addition, we found that the optimal number of stimulation sites essentially depends on how strongly the administered current decays within the neuronal tissue with increasing distance from the stimulation site. In particular, for a broad spatial stimulation profile, i.e., for a weak spatial decay rate of the stimulation current, CR stimulation can optimally be delivered via a small number of stimulation sites. Our findings may contribute to an optimization of therapeutic applications of CR neuromodulation. PMID:23885239

  20. Cooling system with compressor bleed and ambient air for gas turbine engine

    Science.gov (United States)

    Marsh, Jan H.; Marra, John J.

    2017-11-21

    A cooling system for a turbine engine for directing cooling fluids from a compressor to a turbine blade cooling fluid supply and from an ambient air source to the turbine blade cooling fluid supply to supply cooling fluids to one or more airfoils of a rotor assembly is disclosed. The cooling system may include a compressor bleed conduit extending from a compressor to the turbine blade cooling fluid supply that provides cooling fluid to at least one turbine blade. The compressor bleed conduit may include an upstream section and a downstream section whereby the upstream section exhausts compressed bleed air through an outlet into the downstream section through which ambient air passes. The outlet of the upstream section may be generally aligned with a flow of ambient air flowing in the downstream section. As such, the compressed air increases the flow of ambient air to the turbine blade cooling fluid supply.

  1. 49 CFR 570.57 - Air brake system and air-over-hydraulic brake subsystem.

    Science.gov (United States)

    2010-10-01

    ... the drain cocks in the service and supply reservoir on the truck or truck-tractor. Note the pressure.... Close the drain cocks, and, with the trailer(s) uncoupled, check air pressure buildup at the... brakes fully applied. (b) Air brake system hoses, tubes and connections. Air system tubes, hoses and...

  2. The Design of Compressed air system in the Conventional Facility of Proton Accelerator Research Center

    International Nuclear Information System (INIS)

    Jeon, G. P.; Kim, J. Y.; Cho, S. W.; Min, Y. S.; Mun, K. J.; Cho, J. S.; Nam, J. M.; Park, S. S.; Jo, J. H.

    2012-01-01

    The Compressed Air System (CA) supplies compressed air for all air operated devices and instruments, pneumatic equipment and other miscellaneous air user points in the Conventional Facilities of Proton Engineering Frontier Project. CA System consist of the Instrument Air System and the Service air System. The Instrument Air System supplies oil-free, dried, filtered, and compressed instrument air for the air operated control devices and instruments in the Accelerator and Beam Application Building, Ion Beam Application Building, Utility Building and etc.. The Service air System supplies compressed air for pneumatic equipment and other services

  3. Experimental evaluation of air distribution in mechanically ventilated residential rooms

    DEFF Research Database (Denmark)

    Tomasi, R.; Krajčík, M.; Simone, A.

    2013-01-01

    The effect of low ventilation rates (1 or 0.5 air change per hour) on thermal comfort and ventilation effectiveness was experimentally studied in a simulated residential room equipped with radiant floor heating/cooling and mixing ventilation systems. The tests were performed for various positions...... of supply and extract air terminals and different winter and summer boundary conditions. Vertical air temperature, operative temperature and air velocity profiles were measured in different positions in the room, and equivalent temperatures were derived, in order to characterize thermal comfort. Contaminant...... with unconditioned outdoor air supply, i.e. at the supply air temperatures higher than the room air temperature. Moreover, low floor temperatures were needed to maintain the desired reference temperature in the stratified thermal environment. Mainly in cooling conditions the ventilation effectiveness depended...

  4. Air Cleaning Devices for HVAC Supply Systems in Schools. Technical Bulletin.

    Science.gov (United States)

    Wheeler, Arthur E.

    Guidelines for maintaining indoor air quality in schools with HVAC air cleaning systems are provided in this document. Information is offered on the importance of air cleaning, sources of air contaminants and indoor pollutants, types of air cleaners and particulate filters used in central HVAC systems, vapor and gas removal, and performance…

  5. Can a photocatalytic air purifier be used to improve the perceived air quality indoors?

    DEFF Research Database (Denmark)

    Kolarik, Jakub; Wargocki, Pawel

    2010-01-01

    The effect of a photocatalytic air purifier on perceived air quality(PAQ) was examined in rooms polluted by typical sources of indoor pollution.The rooms were ventilated at three different outdoor air supply rates. The air quality was assessed by a sensory panel when the purifier was in operation...... as well as when it was off. Operation of the purifier significantly improved PAQ in the rooms polluted by building materials (used carpet, old linoleum, and old chip-board), and a used ventilation filter as well as a mixture of building materials, used ventilation filter and cathode-ray tube computer...... monitors. The effect cor-responded to approximately doubling the outdoor air supply rate. Operation of the purifier significantly worsened the PAQ in rooms with human bioeffluents, probably due to incomplete oxidation of alcohols which are one of the main pollutants emitted by humans. Present results show...

  6. Adapting transport modes to supply chains classified by the uncertainty supply chain model: A case study at Manaus Industrial Pole

    Directory of Open Access Journals (Sweden)

    Fabiana Lucena Oliveira

    2017-01-01

    Full Text Available This paper discusses transport modes supporting Uncertainty Supply Chain Model (USCM in the case of Manaus Industrial Pole (PIM, an industrial cluster in the Brazilian Amazon that hosts six hundred factories with diverse logistics and supply chain managerial strategies. USCM (Lee, 2002; Fisher, 1997develops a dot matrix classification of the supply chains considering several attributes (e.g., agility, cost, security, responsiveness and argues that emergent economies industrial clusters, in the effort to keep attractiveness for technological frontier firms, need to adapt supply chain strategies according to USCM attributes. The paper takes a further step, discussing which transport modes are suitable to each supply chain classified at the USCM in PIM´s case. The research´s methods covered the use of PIM´s statistical official database (secondary data, interviews with the main logistical services providers of PIM and phone survey with a sample of firms (primary data. Findings confirm the theoretical argument that different supply chains will demand different transport modes running at the same time in the same industrial cluster (Oliveira, 2009. In the case of PIM, this implies investments on port and airport infrastructure and a strategic focus on air transport mode, due to (1 short life cycle of products, (2 distance from suppliers, (3 quick response to demand and (4 the fact that even PIM´s standard products use, in average, forty per cent of air transport at inbound logistics.

  7. Dynamic Performance of a Residential Air-to-Air Heat Pump.

    Science.gov (United States)

    Kelly, George E.; Bean, John

    This publication is a study of the dynamic performance of a 5-ton air-to-air heat pump in a residence in Washington, D.C. The effect of part-load operation on the heat pump's cooling and heating coefficients of performance was determined. Discrepancies between measured performance and manufacturer-supplied performance data were found when the unit…

  8. Seat headrest-incorporated personalized ventilation: Thermal comfort and inhaled air quality

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Ivanova, T.; Stefanova, G.

    2012-01-01

    inhaled by the manikin was measured and used to assess the clean air supply efficiency of the SHPV. The response of 35 subjects was collected to examine thermal comfort with the SHPV. The subjects participated in 3 experiments at personalized air temperature and room air temperature of 22/20 °C, 23/23 °C......The performance of personalized ventilation with seat headrest-mounted air supply terminal devices (ATD), named seat headrest personalized ventilation (SHPV), was studied. Physical measurements using a breathing thermal manikin were taken to identify its ability to provide clean air to inhalation...... depending on design, shape, size and positioning of the ATD, flow rate and temperature of personalized air, room temperature, clothing thermal insulation of the manikin, etc. Tracer gas was mixed with the room air. The air supplied by the SHPV was free of tracer gas. Tracer gas concentration in the air...

  9. Analysis of natural gas supply strategies at Fort Drum

    International Nuclear Information System (INIS)

    Stucky, D.J.; Shankle, S.A.; Anderson, D.M.

    1992-07-01

    This analysis investigates strategies for Fort Drum to acquire a reliable natural gas supply while reducing its gas supply costs. The purpose of this study is to recommend an optimal supply mix based on the life-cycle costs of each strategy analyzed. In particular, this study is intended to provide initial guidance as to whether or not the building and operating of a propane-air mixing station is a feasible alternative to the current gas acquisition strategy. The analysis proceeded by defining the components of supply (gas purchase, gas transport, supplemental fuel supply); identifying alternative options for each supply component; constructing gas supply strategies from different combinations of the options available for each supply component and calculating the life-cycle costs of each supply strategy under a set of different scenarios reflecting the uncertainty of future events

  10. Supply Inventory Management: Industrial Prime Vendor Program at the Air Force Air Logistics Centers

    National Research Council Canada - National Science Library

    2002-01-01

    ... in maintenance, repair, and overhaul facilities. The IPV Program is a customer-oriented, supply-chain management initiative that transfers complete responsibility for bench-stock material to a third-party vendor...

  11. Field-Based Procedures for Screening Diver's Air

    National Research Council Canada - National Science Library

    Lillo, R

    2000-01-01

    The U.S. Navy Diver's Air Sampling Program coordinates use mandatory semi-annual air purity testing of compressors used to supply diver's air in the Fleet The current approach of sending gas-sampling kits...

  12. Influences of the pulsed power supply on corona streamer appearance

    NARCIS (Netherlands)

    Veldhuizen, van E.M.; Briels, T.M.P.; Grabowski, L.R.; Pemen, A.J.M.; Ebert, U.M.

    2005-01-01

    Pulsed positive corona streamers in air are studied by images obtained with an intensified CCD camera. Using a switched capacitor power supply, thin streamers are observed that branch. A power supply consisting of a 4-stage transmission line transformer gives pulses of much higher current to the

  13. Analysis of Direct Outdoor Air Cooling Efficency for Combined Variable Air Volume Air-conditioning System in Stores in Cold Climates of China

    OpenAIRE

    Luo, Zhiwen

    2006-01-01

    Direct outdoor air cooling contributes a lot not only to the improvement of the indoor air quality but also to the energy saving. Its full use will reduce the water chiller’s running time especially in some stores where cooling load keeps much higher and longer than that in other buildings. A novel air-conditioning system named Combined Variable Air Volume system (CVAV), combining a normal AHU with a separate outdoor air supply system, was proposed firstly by the authors. The most attractive ...

  14. Mitigation effects of radon decay products by air cleaner

    International Nuclear Information System (INIS)

    Kazuki Iwaoka; Tetsuo Ishikawa; Hidenori Yonehara; Shinji Tokonami

    2013-01-01

    One of the most effective methods for reducing exposure is the use of air cleaners. In this study, a dose mitigation of a commonly-used Japanese air cleaner under conditions in which aerosols are continuously supplied was investigated. Although the values of the EERC during an operation of air cleaner decreased, values of the f p increased with the use of air cleaner. An effective dose was calculated on the basis of our experimental results, resulting in the dose mitigation of about 40 % by the air cleaner. Air cleaners can be regarded as an effective tool for the dose mitigation under with conditions in which aerosols are continuously supplied. (author)

  15. Design and Implementation of Energy Efficiency in HVAC Systems Based on Robust PID Control for Industrial Applications

    Directory of Open Access Journals (Sweden)

    Muharrem Imal

    2015-01-01

    Full Text Available Energy efficiency in heating, ventilating, and air-conditioning (HVAC systems is a primary concern in process projects, since the energy consumption has the highest percentage in HVAC for all processes. Without sacrifice of thermal comfort, to reset the suitable operating parameters, such as the humidity and air temperature, would have energy saving with immediate effect. In this paper, the simulation-optimization approach described the effective energy efficiency for HVAC systems which are used in industrial process. Due to the complex relationship of the HVAC system parameters, it is necessary to suggest optimum settings for different operations in response to the dynamic cooling loads and changing weather conditions during a year. Proportional-integral-derivative (PID programming was developed which can effectively handle the discrete, nonlinear and highly constrained optimization problems. Energy efficiency process has been made by controlling of alternative current (AC drivers for ventilation and exhaust fans, according to supplied air flow capacity and differential air pressure between supplied and exhaust air. Supervisory controller software was developed by using programmable controllers and human machine interface (HMI units. The new designed HVAC control system would have a saving potential of about 40% as compared to the existing operational settings, without any extra cost.

  16. Performance study of desiccant coated heat exchanger air conditioning system in winter

    International Nuclear Information System (INIS)

    Ge, T.S.; Dai, Y.J.; Wang, R.Z.

    2016-01-01

    Highlights: • Performance of desiccant coated heat exchanger AC system is predicted. • Effects of main operation parameters and climatic conditions are discussed. • Regeneration temperature of 30 °C is recommended under simulation condition. • Higher ambient humidity ratio results in increased humidity ratio of supply air. • Temperature of ambient air has neglectable effect on supply air. - Abstract: Conventional air source heat pump system faces several challenges when adopted in winter season. Solid desiccant air conditioning system can provide humidification and heating power simultaneously and can be driven by low grade thermal energy; it provides a good alternative for air source heat pump systems. However, conventional solid desiccant air conditioning system adopts desiccant wheel with high cost as core component, which hinders the development of such system. Recently, desiccant coated heat exchanger (DCHE) with low initial cost and high efficiency was developed and this paper aims to investigate performance of DCHE air conditioning system adopted in Shanghai winter season. Performance of the system is predicted by a developed mathematical model where supply air states, mass of humidification and coefficient of performance (COP) are adopted as performance indices to evaluate the feasibility and energy utilization ratio of the system. Effects of regeneration water temperature on system performance are analyzed. It is found that under the simulation condition, relatively low regeneration temperature (such as 20 °C) cannot meet the designed standard and relatively high regeneration temperature (such as 40 °C) provides too much extra heating power, thus moderate regeneration temperature around 30 °C is recommended. Meanwhile, switch time is a crucial operation parameter for the system to obtain satisfied supply air, switch time from 40 s to 80 s and from 70 s to 240 s are recommended for transient and average supply air states, respectively. Both

  17. Device for measuring mass of air. Einrichtung zur Luftmassenmessung

    Energy Technology Data Exchange (ETDEWEB)

    Sass, W

    1989-09-28

    In a device for measuring the mass of air, particularly for vehicles with internal combustion engines, with a measurement bridge, in one branch of which an air flow resistance, particularly a hot film sensor, which has air flowing round it, is connected in series with a measuring resistance and in another branch of which a compensation resistance measuring the air temperature is connected in series with a fixed resistor, where the bridge differential voltage is measured in the zero branch of the measuring bridge and the resulting signal is used to control a transistor valve situated in the bridge supply path of a bridge supply source with an emitter connected to the bridge via the transistor base for bridge compensation and where the voltage at the measurement resistance after bridge compensation is evaluated as a measure of the air flow, the invention proposes that the transistor valve should be made as an npn transistor blocking for negative voltage peaks in the bridge supply path. This ensures that for netgative voltage peaks in the supply line, the transistor valve closes temporarily and overheating of the measurement bridge is prevented. Such overheating would lead to measurement of too great air mass flow and therefore to a dangerously too rich fuel/air mixture, for example (instead the negative voltage peaks give a safe temporary lean mixture).

  18. Transcranial magnetic stimulation-induced global propagation of transient phase resetting associated with directional information flow

    Directory of Open Access Journals (Sweden)

    Masahiro eKawasaki

    2014-03-01

    Full Text Available Electroencephalogram (EEG phase synchronization analyses can reveal large-scale communication between distant brain areas. However, it is not possible to identify the directional information flow between distant areas using conventional phase synchronization analyses. In the present study, we applied transcranial magnetic stimulation (TMS to the occipital area in subjects who were resting with their eyes closed, and analyzed the spatial propagation of transient TMS-induced phase resetting by using the transfer entropy (TE, to quantify the causal and directional flow of information. The time-frequency EEG analysis indicated that the theta (5 Hz phase locking factor (PLF reached its highest value at the distant area (the motor area in this study, with a time lag that followed the peak of the transient PLF enhancements of the TMS-targeted area at the TMS onset. PPI (phase-preservation index analyses demonstrated significant phase resetting at the TMS-targeted area and distant area. Moreover, the TE from the TMS-targeted area to the distant area increased clearly during the delay that followed TMS onset. Interestingly, the time lags were almost coincident between the PLF and TE results (152 vs. 165 ms, which provides strong evidence that the emergence of the delayed PLF reflects the causal information flow. Such tendencies were observed only in the higher-intensity TMS condition, and not in the lower-intensity or sham TMS conditions. Thus, TMS may manipulate large-scale causal relationships between brain areas in an intensity-dependent manner. We demonstrated that single-pulse TMS modulated global phase dynamics and directional information flow among synchronized brain networks. Therefore, our results suggest that single-pulse TMS can manipulate both incoming and outgoing information in the TMS-targeted area associated with functional changes.

  19. Quantifying air distribution, ventilation effectiveness and airborne pollutant transport in an aircraft cabin mockup

    Science.gov (United States)

    Wang, Aijun

    The health, safety and comfort of passengers during flight inspired this research into cabin air quality, which is closely related to its airflow distribution, ventilation effectiveness and airborne pollutant transport. The experimental facility is a full-scale aircraft cabin mockup. A volumetric particle tracking velocimetry (VPTV) technique was enhanced by incorporating a self-developed streak recognition algorithm. Two stable recirculation regions, the reverse flows above the seats and the main air jets from the air supply inlets formed the complicated airflow patterns inside the cabin mockup. The primary air flow was parallel to the passenger rows. The small velocity component in the direction of the cabin depth caused less net air exchange between the passenger rows than that parallel to the passenger rows. Different total air supply rate changed the developing behaviors of the main air jets, leading to different local air distribution patterns. Two indices, Local mean age of air and ventilation effectiveness factor (VEF), were measured at five levels of air supply rate and two levels of heating load. Local mean age of air decreased linearly with an increase in the air supply rate, while the VEF remained consistent when the air supply rate varied. The thermal buoyancy force from the thermal plume generated the upside plume flow, opposite to the main jet flow above the boundary seats and thus lowered the local net air exchange. The airborne transport dynamics depends on the distance between the source and the receptors, the relative location of pollutant source, and air supply rate. Exposure risk was significantly reduced with increased distance between source and receptors. Another possible way to decrease the exposure risk was to position the release source close to the exhaust outlets. Increasing the air supply rate could be an effective solution under some emergency situations. The large volume of data regarding the three-dimensional air velocities was

  20. Test of Different Air Distribution Concepts for a Single-Aisle Aircraft Cabin

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Damsgaard, Charlotte; Liu, Li

    2013-01-01

    Traditionally, air is supplied to the aircraft cabin either by individual nozzles or by supply slots. The air is expected to be fully mixed in the cabin, and the system is considered to be a mixing ventilation system. This paper will describe different air distribution systems known from other ap...

  1. Thermal comfort and indoor air quality in rooms with integrated personalized ventilation and under-floor air distribution systems

    DEFF Research Database (Denmark)

    Li, Ruixin; Sekhar ., S. C.; Melikov, Arsen Krikor

    2011-01-01

    A comprehensive study comprising physical measurements and human subject experiments was conducted to explore the potential for improving occupants' thermal comfort and indoor air quality (IAQ) using a personalized ventilation (PV) system combined with an under-floor air distribution(UFAD) system....... The integrated PV-UFAD system, when operated at relatively high temperature of the air supplied from the UFAD system, provided comfortable cooling of the facial region, improved inhaled air quality, and decreased the risk of "cold feet," which is often reported in rooms with UFAD alone. This article explores...... and a secondary AHU for 100% recirculated air that is supplied through UFAD outlets. Velocity and temperature distribution in the chamber were measured. A breathing thermal manikin was used to measure the heat loss from 26 body segments and to determine the equivalent temperature. The responses of 30 human...

  2. Air distribution and ventilation effectiveness in an occupied room heated by warm air

    DEFF Research Database (Denmark)

    Krajcik, Michal; Simone, Angela; Olesen, Bjarne W.

    2012-01-01

    and at different simulated outside conditions, internal heat gains and air change rates. Floor heating was also simulated and compared with the warm air heating system. Vertical air temperature profiles, air velocity profiles and equivalent temperatures were derived in order to describe the thermal environment...... floor heating system was simulated, the cooler ventilation air introduced to the room mixed well and created uniform conditions with a ventilation effectiveness of about 1.......Air distribution, ventilation effectiveness and thermal environment were experimentally studied in a simulated room in a low-energy building heated and ventilated by warm air supplied by a mixing ventilation system. Measurements were performed for various positions of the air terminal devices...

  3. Ventilation air conditioner for a reactor container

    International Nuclear Information System (INIS)

    Ikegame, Noboru; Nakagawa, Takeshi.

    1980-01-01

    Purpose: To suppress the variations in the internal pressure of a reactor container and smoothly ventilate the reactor container. Constitution: The air conditioner provides an air-flow-rate-control damper, a purge-air supply fan, and a filter device in the air-supply pipe of a reactor container. Furthermore, it provides a pressure difference detector at a part of the container. The air-flow-rate-control damper is connected electrically through a position-modulator-comparison amplifier to the pressure difference detector. When the filtration becomes insufficient by clogging of the filter device and the internal pressure increased abruptly in the container, the pressure-difference detector can detect it, and the damper is operated by a pressure regulator and the comparator so as to control the air flow to the container. Thus, the internal pressure variation is controlled so as to easily ventilate the container. (J.P.N.)

  4. Nitrogen gas supply device in nuclear power plant

    International Nuclear Information System (INIS)

    Nishino, Masami

    1991-01-01

    The present invention concerns a nitrogen gas supply device in a nuclear power plant for supplying nitrogen gases to a reactor container and equipments working with the nitrogen gas as the load. A liquid nitrogen storage pool is disposed to a concrete nuclear buildings and has a two-vessel structure of inner and outer vessels, in which heat insulators are disposed between the inner and the outer vessels. Further, the nitrogen gas supply mechanism is disposed in an evaporation chamber disposed in adjacent with the liquid nitrogen storage pool in the reator building. Accordingly, since liquid nitrogen is stored in the liquid nitrogen storage pool having a structure surrounded by concrete walls, direct sunlight is completely interrupted, thereby enabling to prevent the heat caused by the direct sunlight from conducting to the liquid nitrogen. Further, since the outer vessel is not exposed to the surrounding atmosphere, heat conduction rate relative to the external air is small. This can reduce the amount of liquid nitrogen released to the atmospheric air due to natural evaporation. (I.N.)

  5. EEG PHASE RESET OF THE DEFAULT MODE NETWORK

    Directory of Open Access Journals (Sweden)

    Robert W. Thatcher

    2014-07-01

    Full Text Available Objectives: The purpose of this study was to explore phase reset of 3-dimensional current sources located in Brodmann areas located in the human default mode network (DMN using Low Resolution Electromagnetic Tomography (LORETA of the human electroencephalogram (EEG. Methods: The EEG was recorded from 19 scalp locations from 70 healthy normal subjects ranging in age from 13 to 20 years. A time point by time point computation of LORETA current sources were computed for 14 Brodman areas comprising the DMN in the delta frequency band. The Hilbert transform of the LORETA time series was used to compute the instantaneous phase differences between all pairs of Brodmann areas. Phase shift and lock durations were calculated based on the 1st & 2nd derivatives of the time series of phase differences. Results: Phase shift duration exhibited three discrete modes at approximately: 1- 30 msec,, 2- 55 msec and, 3- 65 msec. Phase lock duration present primarily at: 1- 300 to 350 msec and, 2- 350 msec to 450 msec. Phase shift and lock durations were inversely related and exhibited an exponential change with distance between Brodmann areas. Conclusions: The results are explained by local neural packing density of network hubs and an exponential decrease in connections with distance from a hub. The results are consistent with a discrete temporal model of brain function where anatomical hubs behave like a ‘shutter’ that opens and closes at specific durations as nodes of a network giving rise to temporarily phase locked clusters of neurons for specific durations.

  6. 29 CFR 1926.803 - Compressed air.

    Science.gov (United States)

    2010-07-01

    ... ventilated, and there shall be no pockets of dead air. Outlets may be required at intermediate points along the main low-pressure air supply line to the heading to eliminate such pockets of dead air... of structures of wood over or near shafts. (6) Tunnels shall be provided with a 2-inch minimum...

  7. AltitudeOmics: Resetting of cerebrovascular CO2 reactivity following acclimatization to high altitude

    Directory of Open Access Journals (Sweden)

    Jui-Lin eFan

    2016-01-01

    Full Text Available Previous studies reported enhanced cerebrovascular CO2 reactivity upon ascent to high altitude using linear models. However, there is evidence that this response may be sigmoidal in nature. Moreover, it was speculated that these changes at high altitude are mediated by alterations in acid-base buffering. Accordingly, we reanalyzed previously published data to assess middle cerebral blood flow velocity (MCAv responses to modified rebreathing at sea level (SL, upon ascent (ALT1 and following 16 days of acclimatization (ALT16 to 5,260 m in 21 lowlanders. Using sigmoid curve fitting of the MCAv responses to CO2, we found the amplitude (95% vs. 129%, SL vs. ALT1, 95% confidence intervals (CI [77, 112], [111, 145], respectively, P=0.024 and the slope of the sigmoid response (4.5 vs. 7.5 %/mmHg, SL vs. ALT1, 95% CIs [3.1, 5.9], [6.0, 9.0], respectively, P=0.026 to be enhanced at ALT1, which persisted with acclimatization at ALT16 (amplitude: 177%, 95% CI [139, 215], P<0.001; slope: 10.3 %/mmHg, 95% CI [8.2, 12.5], P=0.003 compared to SL. Meanwhile, the sigmoidal response midpoint was unchanged at ALT1 (SL: 36.5 mmHg; ALT1: 35.4 mmHg, 95% CIs [34.0, 39.0], [33.1, 37.7], respectively, P=0.982, while it was reduced by ~7 mmHg at ALT16 (28.6 mmHg, 95% CI [26.4, 30.8], P=0.001 vs. SL, indicating leftward shift of the cerebrovascular CO2 response to a lower arterial partial pressure of CO2 (PaCO2 following acclimatization to altitude. Sigmoid fitting revealed a leftward shift in the midpoint of the cerebrovascular response curve which could not be observed with linear fitting. These findings demonstrate that there is resetting of the cerebrovascular CO2 reactivity operating point to a lower PaCO2 following acclimatization to high altitude. This cerebrovascular resetting is likely the result of an altered acid-base buffer status resulting from prolonged exposure to the severe hypocapnia associated with ventilatory acclimatization to high altitude.

  8. DEVELOPMENT OF TECHNICAL DECISIONS FOR HEAT SUPPLY WITH TUBULAR GAS HEATERS

    Directory of Open Access Journals (Sweden)

    IRODOV V. F.

    2017-05-01

    Full Text Available Annotation. Problems formulation. The problem that is solved is the development of autonomous heat supply systems that reduce the capital costs of construction and increase the efficiency of the use of energy resources. One of the ways to solve this problem is the use of tubular gas heaters. For this, it is necessary to develop new technical solutions for heat supply with tubular gas heaters, as well as scientific and methodological support for the development, construction and operation of heat supply systems with tubular gas heaters. Analysis of recent research. Preliminary studies of infrared tubular gas heaters are considered, which were used to heat industrial enterprises with sufficiently high premises. The task was to extend the principles of heat supply by means of tubular heaters for heating air, water and heating medium in relatively low rooms. Goal and tasks. To lay out the development of technical solutions for heat supply with tubular gas heaters, which increase the efficiency and reliability of heat supply systems and extend the use of tubular gas heaters in heat supply. Results. Technical solutions for heat supply with tubular gas heaters have made it possible to extend their applications for heating air, water and heating medium in relatively low rooms. Scientific novelty. New technical solutions for heat supply with tubular gas heaters increase the efficiency of using fuel and energy resources at low capital costs. Practical significance. Technical solutions for heat supply using tubular heaters have the potential for wide application in the heat supply of industrial, public and residential facilities. Conclusions. For two decades, new technical solutions for heat supply with tubular gas heaters have been developed, which increase the efficiency and reliability of heat supply systems and can be widely used for autonomous heating.

  9. Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating, Ventilation and Air-Conditioning (HVAC) system for the computer room of the CERN Control Centre

    CERN Document Server

    2012-01-01

    Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating, Ventilation and Air-Conditioning (HVAC) system for the computer room of the CERN Control Centre

  10. Sensitivity to draught in turbulent air flows

    Energy Technology Data Exchange (ETDEWEB)

    Todde, V

    1998-09-01

    Even though the ventilation system is designed to supply air flows at constant low velocity and controlled temperature, the resulting air movement in rooms is strongly characterised by random fluctuations. When an air flow is supplied from an inlet, a shear layer forms between the incoming and the standstill air in the room, and large scale vortices develops by coalescence of the vorticity shed at the inlet of the air supply. After a characteristically downstream distance, large scale vortices loose their identity because of the development of cascading eddies and transition to turbulence. The interaction of these vortical structures will rise a complicated three dimensional air movement affected by fluctuations whose frequencies could vary from fractions of Hz to several KHz. The perception and sensitivity to the cooling effect enhanced by these air movements depend on a number of factors interacting with each other: physical properties of the air flow, part and extension of the skin surface exposed to the air flow, exposure duration, global thermal condition, gender and posture of the person. Earlier studies were concerned with the percentage of dissatisfied subjects as a function of air velocity and temperature. Recently, experimental observations have shown that also the fluctuations, the turbulence intensity and the direction of air velocity have an important impact on draught discomfort. Two experimental investigations have been developed to observe the human reaction to horizontal air movements on bared skin surfaces, hands and neck. Attention was concentrated on the effects of relative turbulence intensity of air velocity and exposure duration on perception and sensitivity to the air movement. The air jet flows, adopted for the draught experiment in the neck, were also the object of an experimental study. This experiment was designed to observe the centre-line velocity of an isothermal circular air jet, as a function of the velocity properties at the outlet

  11. Solar-powered hot-air system

    Science.gov (United States)

    1979-01-01

    Solar-powered air heater supplies part or all of space heating requirements of residential or commercial buildings and is interfaced with air to water heat exchanger to heat domestic hot water. System has potential application in drying agricultural products such as cotton, lumber, corn, grains, and peanuts.

  12. Laser sheet light flow visualization for evaluating room air flowsfrom Registers

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain S.; Claret, Valerie; Smith, Brian

    2006-04-01

    Forced air heating and cooling systems and whole house ventilation systems deliver air to individual rooms in a house via supply registers located on walls ceilings or floors; and occasionally less straightforward locations like toe-kicks below cabinets. Ideally, the air velocity out of the registers combined with the turbulence of the flow, vectoring of air by register vanes and geometry of register placement combine to mix the supply air within the room. A particular issue that has been raised recently is the performance of multiple capacity and air flow HVAC systems. These systems vary the air flow rate through the distribution system depending on the system load, or if operating in a ventilation rather than a space conditioning mode. These systems have been developed to maximize equipment efficiency, however, the high efficiency ratings do not include any room mixing effects. At lower air flow rates, there is the possibility that room air will be poorly mixed, leading to thermal stratification and reduced comfort for occupants. This can lead to increased energy use as the occupants adjust the thermostat settings to compensate and parts of the conditioned space have higher envelope temperature differences than for the well mixed case. In addition, lack of comfort can be a barrier to market acceptance of these higher efficiency systems To investigate the effect on room mixing of reduced air flow rates requires the measurement of mixing of supply air with room air throughout the space to be conditioned. This is a particularly difficult exercise if we want to determine the transient performance of the space conditioning system. Full scale experiments can be done in special test chambers, but the spatial resolution required to fully examine the mixing problem is usually limited by the sheer number of thermal sensors required. Current full-scale laboratory testing is therefore severely limited in its resolution. As an alternative, we used a water-filled scale model

  13. Relations between Air-Fuel Ratio and Dynamic Performance of Small Race Cars

    OpenAIRE

    位田, 晴良; Ida, Haruyoshi; 漁, 佑一郎; Sunadori, Yuichiro; 牧田, 俊太郎; Makita, Syuntaro; 宮﨑, 真央; Miyazaki, Manaka; 磯松, 弥司; Isomatsu, Yatsuka

    2017-01-01

    'It goes without saying that engine output power characteristics greatly affect the dynamic performance of the race car. One of the methods of changing the output power of the engine is to adjust the set amount of fuel supply. This method changes the air-fuel ratio of the air fuel mixture supplied to the engine. In this study, a slalom test run of a small race car was used to examine dynamic performance with attention to the air-fuel ratio changed by adjusting the set amount of fuel supply. T...

  14. The Restoration of Chronotropic CompEtence in Heart Failure PatientS with Normal Ejection FracTion (RESET) Study: Rationale and Design

    Science.gov (United States)

    Kass, David A.; Kitzman, Dalane W.; Alvarez, Guy E.

    2009-01-01

    Background Heart failure with preserved ejection fraction (HFpEF) is the predominant form of HF among the elderly and in women. However, there are few if any evidence-based therapeutic options for HFpEF. The chief complaint of HFpEF is reduced tolerance to physical exertion. Recent data revealed that one potential mechanism of exertional intolerance in HFpEF patients is inadequate chronotropic response. Although there is considerable evidence demonstrating the benefits of rate-adaptive pacing (RAP) provided from implantable cardiac devices in patients with an impaired chronotropic response, the effect of RAP in HFpEF is unknown. Methods and Results The RESET study is a prospective, multi-center, double-blind, randomized with stratification, study assessing the effect of RAP on peak VO2 and quality of life. RAP therapy will be evaluated in a cross-over paired fashion for each patient within each study stratum. Study strata are based on patient beta-blocker usage at time of enrollment. The study is powered to assess the impact of pacing independently in both strata. Conclusions The RESET study seeks to evaluate the potential benefit of RAP in patients with symptomatic mild to moderate HFpEF and chronotropic impairment. Study enrollment began in July 2008. PMID:20123314

  15. Logistics Supply of the Distributed Air Wing

    Science.gov (United States)

    2014-09-01

    Event Graph The Consumption Process first instantiates the variables . The model follows a conveyor belt pattern, whereby after processing an event...the following problem statement: Design a system of systems and the concept of operations to employ naval air assets in a range of missions to augment...airbases are designed to be set up within three days, utilizing highways as short runways for the Short Take Off Vertical Landing (STOVL) aircraft F

  16. The role of leak air in a double-wall chimney

    Science.gov (United States)

    Lichtenegger, Klaus; Hebenstreit, Babette; Pointner, Christian; Schmidl, Christoph; Höftberger, Ernst

    2015-06-01

    In modern buildings with tight shells, often room-independent air supply is required for proper operation of biomass stoves. One possibility to arrange this supply is to use a double-wall chimney with flue gas leaving through the pipe and fresh air entering through the annular gap. A one-dimensional quasi-static model based on balance equations has been developed and compared with experimental data. Inclusion of leak air is crucial for reproduction of the experimental results.

  17. Emergency power supply with batteries. Notstromversorgung mit Batterien

    Energy Technology Data Exchange (ETDEWEB)

    1983-01-01

    This conference volume contains the wording of the following 16 papers given at the symposium: ''Stationary Pb batteries''; ''maintenance-free Pb batteries with antimony-free grid plates or tube plates and dry fit system''; ''stationary alkali, Ag/Zc and gas-tight Ni/Cd batteries''; ''modern Li systems''; ''high-temperature batteries''; ''primary and secondary metal-air cells''; ''peak-load coverage with Pb batteries in distribution networks and industrial plants''; ''Success and problems with national and international standardization''; ''electronic monitoring of batteries'', ''up-to-date charging and converter technology''; ''versatile emergency power supply with the Federal German Railways''; ''emergency lighting''; ''emergency power supply in large-scale industrial plants''; ''battery power supply with the Federal German Post and Telecommunications''; ''Power supply to modern communication facilities''; ''modular d.-c. converter''; ''back-up power supply in the military field''; and it contains the wording of the discussions following the papers.

  18. Supply Ventilation and Prevention of Carbon Monoxide (II) Ingress into Building Premises

    Science.gov (United States)

    Litvinova, N. A.

    2017-11-01

    The article contains the relationships of carbon monoxide (II) concentration versus height-above-ground near buildings derived based on results of studies. The results of studies are crucial in preventing external pollutants ingress into a ventilation system. Being generated by external emission sources, such as motor vehicles and city heating plants, carbon monoxide (II) enters the premises during operation of a supply ventilation system. Fresh air nomographic charts were drawn to select the height of a fresh air intake into the ventilation system. Nomographic charts take into account external sources. The selected emission sources are located at various levels above ground relative to the building. The recommendations allow designing supply ventilation taking into account the quality of ambient air through the whole building height.

  19. Microbiological contamination of compressed air used in dentistry: an investigation.

    Science.gov (United States)

    Conte, M; Lynch, R M; Robson, M G

    2001-11-01

    The purpose of this preliminary investigation was twofold: 1) to examine the possibility of cross-contamination between a dental-evacuation system and the compressed air used in dental operatories and 2) to capture and identify the most common microflora in the compressed-air supply. The investigation used swab, water, and air sampling that was designed to track microorganisms from the evacuation system, through the air of the mechanical room, into the compressed-air system, and back to the patient. Samples taken in the vacuum system, the air space in the mechanical room, and the compressed-air storage tank had significantly higher total concentrations of bacteria than the outside air sampled. Samples of the compressed air returning to the operatory were found to match the outside air sample in total bacteria. It was concluded that the air dryer may have played a significant role in the elimination of microorganisms from the dental compressed-air supply.

  20. Personalized ventilation: evaluation of different air terminal devices

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Cermak, Radim; Majer, M.

    2002-01-01

    Personalized ventilation (PV) aims to provide clean air to the breathing zone of occupants. Its performance depends to a large extent on the supply air terminal device (ATD). Five different ATDs were developed, tested and compared. A typical office workplace consisting of a desk with mounted ATDs...... was simulated in a climate chamber. A breathing thermal manikin was used to simulate a human being. Experiments at room air temperatures of 26 and 20 deg.C and personalized air temperatures of 20 deg.C supplied from the ATDs were performed. The flow rate of personalized air was changed from less than 5 up to 23...... l/s. Tracer gas was used to identify the amount of personalized air inhaled by the manikin as well as the amount of exhaled air re-inhaled. The heat loss from the body segments of the thermal manikin was measured and used to calculate the equivalent temperature for the whole body as well as segments...

  1. Smart timer for use in air purifiers; Temporizador inteligente para utilizacao em depuradores de ar

    Energy Technology Data Exchange (ETDEWEB)

    Marcelino, M.A.; Escudeiro, G.A. [Universidade Estadual Paulista (FEG/UNESP), Guaratingueta, SP (Brazil). Faculdade de Engenharia], Emails: abud@feg.unesp.br, gui_paulista@yahoo.com.br

    2009-07-01

    Currently, the air cleaner Suggar appliances has a key of three positions of different speeds, in addition to the off position. The motor has three windings, each one is responsible for a winding speed. The speed choice is made through the key. The objective of this work is the replacement of this motor with three windings by a single motor winding, with the velocity controlled electronically, and no longer using the key, lowering the costs of product. A signalling was implemented, through a diode LED, informing the user the end of the useful life of the debugger filter, in order to make possible the replacement at the right time, avoiding waste for the product user. The electronic system should be able to control the speed of engine and to count a total of 100 hours of operation of the debugger. When this is achieved, a signal is triggered on the front panel of product, indicating the need for replacing the filter. A key to reset the timer will used to reset the count after a filter change. To avoid the time counting due to the energy lack it is used an EEPROM memory to storage the counting. The control system counting is done by the PIC12F629 microcontroller.

  2. Risk benefits of climate-friendly energy supply options

    International Nuclear Information System (INIS)

    Hirschberg, S.; Burgherr, P.

    2003-01-01

    One of the central goals of sustainable development is the reduction of Greenhouse Gas (GHG) emissions. This is needed in order to prevent the anticipated climate change, and the potentially serious consequences for human beings and the environment. Energy supply systems constitute the dominant contributors to GHG emissions. This paper examines three illustrative emission scenarios for world-wide energy supply in the 21 st Century. These scenarios, including the associated GHG and major pollutant emissions, were chosen from a set established by the Intergovernmental Panel on Climate Change (IPCC). Using the emissions as a starting point, and based on recent findings concerning the impact on the environment and the financial costs resulting from global climate change on the one hand, and regional air pollution on the other hand, the present work provides estimates of the scenario-dependent, world-wide cumulative damage. The fossil-intensive reference scenario leads to overall damages which correspond to very substantial losses in Gross Domestic Product (GDP), and which widely exceed the damages caused by the scenarios reflecting climate-friendly policies. Generally, the somewhat speculative estimates of the GHG-specific damages are much less significant than damages to human health and the environment caused by the major air pollutants. This means that the secondary benefits of climate-friendly, energy-supply options, i.e. those which avoid the impacts due to air pollution, alone justify strategies protecting the climate. (author)

  3. Secondary air injection system and method

    Science.gov (United States)

    Wu, Ko-Jen; Walter, Darrell J.

    2014-08-19

    According to one embodiment of the invention, a secondary air injection system includes a first conduit in fluid communication with at least one first exhaust passage of the internal combustion engine and a second conduit in fluid communication with at least one second exhaust passage of the internal combustion engine, wherein the at least one first and second exhaust passages are in fluid communication with a turbocharger. The system also includes an air supply in fluid communication with the first and second conduits and a flow control device that controls fluid communication between the air supply and the first conduit and the second conduit and thereby controls fluid communication to the first and second exhaust passages of the internal combustion engine.

  4. Low-power priority Address-Encoder and Reset-Decoder data-driven readout for Monolithic Active Pixel Sensors for tracker system

    International Nuclear Information System (INIS)

    Yang, P.; Aglieri, G.; Cavicchioli, C.; Chalmet, P.L.; Chanlek, N.; Collu, A.; Gao, C.; Hillemanns, H.; Junique, A.; Kofarago, M.; Keil, M.; Kugathasan, T.; Kim, D.; Kim, J.; Lattuca, A.; Marin Tobon, C.A.; Marras, D.; Mager, M.; Martinengo, P.; Mazza, G.

    2015-01-01

    Active Pixel Sensors used in High Energy Particle Physics require low power consumption to reduce the detector material budget, low integration time to reduce the possibilities of pile-up and fast readout to improve the detector data capability. To satisfy these requirements, a novel Address-Encoder and Reset-Decoder (AERD) asynchronous circuit for a fast readout of a pixel matrix has been developed. The AERD data-driven readout architecture operates the address encoding and reset decoding based on an arbitration tree, and allows us to readout only the hit pixels. Compared to the traditional readout structure of the rolling shutter scheme in Monolithic Active Pixel Sensors (MAPS), AERD can achieve a low readout time and a low power consumption especially for low hit occupancies. The readout is controlled at the chip periphery with a signal synchronous with the clock, allows a good digital and analogue signal separation in the matrix and a reduction of the power consumption. The AERD circuit has been implemented in the TowerJazz 180 nm CMOS Imaging Sensor (CIS) process with full complementary CMOS logic in the pixel. It works at 10 MHz with a matrix height of 15 mm. The energy consumed to read out one pixel is around 72 pJ. A scheme to boost the readout speed to 40 MHz is also discussed. The sensor chip equipped with AERD has been produced and characterised. Test results including electrical beam measurement are presented

  5. Low-power priority Address-Encoder and Reset-Decoder data-driven readout for Monolithic Active Pixel Sensors for tracker system

    Energy Technology Data Exchange (ETDEWEB)

    Yang, P., E-mail: yangping0710@126.com [Central China Normal University, Wuhan (China); Aglieri, G.; Cavicchioli, C. [CERN, 1210 Geneva 23 (Switzerland); Chalmet, P.L. [MIND, Archamps (France); Chanlek, N. [Suranaree University of Technology, Nakhon Ratchasima (Thailand); Collu, A. [University of Cagliari, Cagliari (Italy); INFN (Italy); Gao, C. [Central China Normal University, Wuhan (China); Hillemanns, H.; Junique, A. [CERN, 1210 Geneva 23 (Switzerland); Kofarago, M. [CERN, 1210 Geneva 23 (Switzerland); University of Utrecht, Utrecht (Netherlands); Keil, M.; Kugathasan, T. [CERN, 1210 Geneva 23 (Switzerland); Kim, D. [Dongguk and Yonsei University, Seoul (Korea, Republic of); Kim, J. [Pusan National University, Busan (Korea, Republic of); Lattuca, A. [University of Torino, Torino (Italy); INFN (Italy); Marin Tobon, C.A. [CERN, 1210 Geneva 23 (Switzerland); Marras, D. [University of Cagliari, Cagliari (Italy); INFN (Italy); Mager, M.; Martinengo, P. [CERN, 1210 Geneva 23 (Switzerland); Mazza, G. [University of Torino, Torino (Italy); INFN (Italy); and others

    2015-06-11

    Active Pixel Sensors used in High Energy Particle Physics require low power consumption to reduce the detector material budget, low integration time to reduce the possibilities of pile-up and fast readout to improve the detector data capability. To satisfy these requirements, a novel Address-Encoder and Reset-Decoder (AERD) asynchronous circuit for a fast readout of a pixel matrix has been developed. The AERD data-driven readout architecture operates the address encoding and reset decoding based on an arbitration tree, and allows us to readout only the hit pixels. Compared to the traditional readout structure of the rolling shutter scheme in Monolithic Active Pixel Sensors (MAPS), AERD can achieve a low readout time and a low power consumption especially for low hit occupancies. The readout is controlled at the chip periphery with a signal synchronous with the clock, allows a good digital and analogue signal separation in the matrix and a reduction of the power consumption. The AERD circuit has been implemented in the TowerJazz 180 nm CMOS Imaging Sensor (CIS) process with full complementary CMOS logic in the pixel. It works at 10 MHz with a matrix height of 15 mm. The energy consumed to read out one pixel is around 72 pJ. A scheme to boost the readout speed to 40 MHz is also discussed. The sensor chip equipped with AERD has been produced and characterised. Test results including electrical beam measurement are presented.

  6. Low-power priority Address-Encoder and Reset-Decoder data-driven readout for Monolithic Active Pixel Sensors for tracker system

    Science.gov (United States)

    Yang, P.; Aglieri, G.; Cavicchioli, C.; Chalmet, P. L.; Chanlek, N.; Collu, A.; Gao, C.; Hillemanns, H.; Junique, A.; Kofarago, M.; Keil, M.; Kugathasan, T.; Kim, D.; Kim, J.; Lattuca, A.; Marin Tobon, C. A.; Marras, D.; Mager, M.; Martinengo, P.; Mazza, G.; Mugnier, H.; Musa, L.; Puggioni, C.; Rousset, J.; Reidt, F.; Riedler, P.; Snoeys, W.; Siddhanta, S.; Usai, G.; van Hoorne, J. W.; Yi, J.

    2015-06-01

    Active Pixel Sensors used in High Energy Particle Physics require low power consumption to reduce the detector material budget, low integration time to reduce the possibilities of pile-up and fast readout to improve the detector data capability. To satisfy these requirements, a novel Address-Encoder and Reset-Decoder (AERD) asynchronous circuit for a fast readout of a pixel matrix has been developed. The AERD data-driven readout architecture operates the address encoding and reset decoding based on an arbitration tree, and allows us to readout only the hit pixels. Compared to the traditional readout structure of the rolling shutter scheme in Monolithic Active Pixel Sensors (MAPS), AERD can achieve a low readout time and a low power consumption especially for low hit occupancies. The readout is controlled at the chip periphery with a signal synchronous with the clock, allows a good digital and analogue signal separation in the matrix and a reduction of the power consumption. The AERD circuit has been implemented in the TowerJazz 180 nm CMOS Imaging Sensor (CIS) process with full complementary CMOS logic in the pixel. It works at 10 MHz with a matrix height of 15 mm. The energy consumed to read out one pixel is around 72 pJ. A scheme to boost the readout speed to 40 MHz is also discussed. The sensor chip equipped with AERD has been produced and characterised. Test results including electrical beam measurement are presented.

  7. The Ontario Energy Board`s draft standard supply service code: effects on air quality

    Energy Technology Data Exchange (ETDEWEB)

    Gibbons, J.; Bjorkquist, S. [Ontario Clean Air Alliance, Toronto, ON (Canada)

    1999-06-29

    The Ontario Clean Air Alliance (OCAA), a coalition of 67 organizations, takes issue with the Ontario Energy Board`s draft document `Standard Supply Service Code`, particularly sections 2.2.2. and 2.5.2 which they claim are not in the public interest unless the Ontario government implements the OCAA`s recommended emission caps. The alliance is of the view that without strict new environmental regulations the proposed Code would encourage the use of coal for electricity generation. Public health, the environment, consumer interests, job creation and promotion of a competitive electricity market would all be jeopardized by this development, the alliance states. The argument is supported by extensive reference to the Final Report of the Ontario Market Design Committee (MDC) which also emphasized the importance of combining the introduction of competition with appropriate environmental regulations, singling out the emission cap and trade program, and recommending that it be launched concurrently with the electricity market opening for competition. The view of the MDC was that public support for restructuring would not be forthcoming in the absence of regulatory measures to control power plant emissions. 25 refs.

  8. LORETA EEG phase reset of the default mode network.

    Science.gov (United States)

    Thatcher, Robert W; North, Duane M; Biver, Carl J

    2014-01-01

    The purpose of this study was to explore phase reset of 3-dimensional current sources in Brodmann areas located in the human default mode network (DMN) using Low Resolution Electromagnetic Tomography (LORETA) of the human electroencephalogram (EEG). The EEG was recorded from 19 scalp locations from 70 healthy normal subjects ranging in age from 13 to 20 years. A time point by time point computation of LORETA current sources were computed for 14 Brodmann areas comprising the DMN in the delta frequency band. The Hilbert transform of the LORETA time series was used to compute the instantaneous phase differences between all pairs of Brodmann areas. Phase shift and lock durations were calculated based on the 1st and 2nd derivatives of the time series of phase differences. Phase shift duration exhibited three discrete modes at approximately: (1) 25 ms, (2) 50 ms, and (3) 65 ms. Phase lock duration present primarily at: (1) 300-350 ms and (2) 350-450 ms. Phase shift and lock durations were inversely related and exhibited an exponential change with distance between Brodmann areas. The results are explained by local neural packing density of network hubs and an exponential decrease in connections with distance from a hub. The results are consistent with a discrete temporal model of brain function where anatomical hubs behave like a "shutter" that opens and closes at specific durations as nodes of a network giving rise to temporarily phase locked clusters of neurons for specific durations.

  9. High amplitude phase resetting in rev-erbalpha/per1 double mutant mice.

    Directory of Open Access Journals (Sweden)

    Corinne Jud

    Full Text Available Over time, organisms developed various strategies to adapt to their environment. Circadian clocks are thought to have evolved to adjust to the predictable rhythms of the light-dark cycle caused by the rotation of the Earth around its own axis. The rhythms these clocks generate persist even in the absence of environmental cues with a period of about 24 hours. To tick in time, they continuously synchronize themselves to the prevailing photoperiod by appropriate phase shifts. In this study, we disrupted two molecular components of the mammalian circadian oscillator, Rev-Erbalpha and Period1 (Per1. We found that mice lacking these genes displayed robust circadian rhythms with significantly shorter periods under constant darkness conditions. Strikingly, they showed high amplitude resetting in response to a brief light pulse at the end of their subjective night phase, which is rare in mammals. Surprisingly, Cry1, a clock component not inducible by light in mammals, became slightly inducible in these mice. Taken together, Rev-Erbalpha and Per1 may be part of a mechanism preventing drastic phase shifts in mammals.

  10. Study of air flow and temperature distribution in ship's crew cabins

    Energy Technology Data Exchange (ETDEWEB)

    Elsafty, A.F. [Arab Academy for Science and Technology and Maritime Transport, Alexandria (Egypt). Dept. of Mechanical and Marine Engineering; Ali, A.A.; Nasr, A.N. [Arab Academy for Science and Technology and Maritime Transport, Alexandria (Egypt). Dept. of Marine Engineering Technology

    2007-07-01

    Because of low internal heights in ship's crew cabins, the supplied air is directed to the persons at low mixing ratios. However, this does not allow the mixing process between the supplied air and the indoor air to be completed before the air enters human lungs. This paper presented an experimental and numerical simulation study that used computational fluid dynamics (CFD) to investigate the effect of the air supply location on thermal air diffusion in the ship's crew cabins space. The paper presented the results in terms of air diffusion performance index. The paper presented the CFD model, including selected space configurations; CFD simulation; boundary conditions; and CFD results. The CFD airflow simulation programs CFD were utilized to calculate the spatial distribution of temperature and velocity. The study focused on the typical Middle East region working vessel under thermal and boundary conditions including the high cooling load used in this region. Experimental data were also introduced to verify the CFD results package. It was concluded that the supply should be located near the high sidewall of the cabin. This gives better air distribution inside the space rather than the center of the room. 5 refs., 1 tab., 6 figs.

  11. Direct Digital Control of HVAC (Heating, Ventilating, and Air Conditioning).

    Science.gov (United States)

    1985-01-01

    controller func- tions such as time-of-day, economizer cycles, reset, load shedding, chiller optimization , VAV fan synchronization, and optimum start/stop...control system such as that illustrated in Fig- urc 4. Data on setpoints , reset schedules, and event timing, such as that presented in Figure 6, are...program code (Figure 7). In addition to the control logic, setpoint and other data are readily available. Program logi:, setpoint and schedule data, and

  12. PEMILIHAN SISTEM PENYEDIAAN AIR BAKU DI PULAU KAHAKITANG KABUPATEN KEPULAUAN SANGIHE

    Directory of Open Access Journals (Sweden)

    Ariestides Dundu

    2013-02-01

    tertinggi kedua yaitu ABSAH. Untuk Desa Batusaiki Taleko dusun Batusaiki didapatkan nilai tertinggi untuk sistem penyediaan air dengan menggunakan Mata air/sumur. Sebagai alternatif dapat diambil nilai tertinggi kedua yaitu IPA-RO, dan Untuk Desa Batusaiki Taleko dusun Taleko didapatkan nilai tertinggi untuk system penyediaan air dengan menggunakan ABSAH. Sebagai alternatif dapat diambil nilai tertinggi kedua yaitu perahu air. Kata kunci : Pulau Kahakitang, Sistem Penyediaan Air Baku, AHP   Abstract   Sangihe Islands District consists of several small islands that have problems in the availability of raw water. Of several small islands there, Kahakitang island, has several water sources that can be utilized as a provider of raw water such as springs, wells, rain water and sea water. But the distance between the hamlets island located far from each other in addition to one in the highlands and in the lowlands, the hamlets in the far-flung villages and there are in different catchment areas, and the discharge of water from the spring / well very small, so that the existing water sources have not been able to supply water thoroughly. Raw Water Supply System what meets the various criteria to be used in Kahakitang Island? In the Analytic Hierarchy Process (AHP is used criteria: Water Availability, Cost, Compliance Location, Ease of Implementation, and Maintenance, with the alternative: Water Treatment Plant with Reverse Osmosis (RO IPA, Aquifer Artificial Rain Water Savings (INVALID , The pipeline from the water source, and Boat Water in solving these problems. The results in the selection of raw water supply system Kahakitang Island are: to village hamlet Behongan Soa, IPA-RO system is an option that has the highest value. An alternative could be taken the second highest water boat. For Behongan village hamlet Sowang, the value obtained from the system taking from the springs is an option that has the highest value. As an alternative to the second highest value is taken IPA

  13. Rituximab does not reset defective early B cell tolerance checkpoints

    Science.gov (United States)

    Chamberlain, Nicolas; Massad, Christopher; Oe, Tyler; Cantaert, Tineke; Herold, Kevan C.; Meffre, Eric

    2015-01-01

    Type 1 diabetes (T1D) patients show abnormalities in early B cell tolerance checkpoints, resulting in the accumulation of large numbers of autoreactive B cells in their blood. Treatment with rituximab, an anti-CD20 mAb that depletes B cells, has been shown to preserve β cell function in T1D patients and improve other autoimmune diseases, including rheumatoid arthritis and multiple sclerosis. However, it remains largely unknown how anti–B cell therapy thwarts autoimmunity in these pathologies. Here, we analyzed the reactivity of Abs expressed by single, mature naive B cells from 4 patients with T1D before and 52 weeks after treatment to determine whether rituximab resets early B cell tolerance checkpoints. We found that anti–B cell therapy did not alter the frequencies of autoreactive and polyreactive B cells, which remained elevated in the blood of all patients after rituximab treatment. Moreover, the limited proliferative history of autoreactive B cells after treatment revealed that these clones were newly generated B cells and not self-reactive B cells that had escaped depletion and repopulated the periphery through homeostatic expansion. We conclude that anti–B cell therapy may provide a temporary dampening of autoimmune processes through B cell depletion. However, repletion with autoreactive B cells may explain the relapse that occurs in many autoimmune patients after anti–B cell therapy. PMID:26642366

  14. Phase resetting reveals network dynamics underlying a bacterial cell cycle.

    Science.gov (United States)

    Lin, Yihan; Li, Ying; Crosson, Sean; Dinner, Aaron R; Scherer, Norbert F

    2012-01-01

    Genomic and proteomic methods yield networks of biological regulatory interactions but do not provide direct insight into how those interactions are organized into functional modules, or how information flows from one module to another. In this work we introduce an approach that provides this complementary information and apply it to the bacterium Caulobacter crescentus, a paradigm for cell-cycle control. Operationally, we use an inducible promoter to express the essential transcriptional regulatory gene ctrA in a periodic, pulsed fashion. This chemical perturbation causes the population of cells to divide synchronously, and we use the resulting advance or delay of the division times of single cells to construct a phase resetting curve. We find that delay is strongly favored over advance. This finding is surprising since it does not follow from the temporal expression profile of CtrA and, in turn, simulations of existing network models. We propose a phenomenological model that suggests that the cell-cycle network comprises two distinct functional modules that oscillate autonomously and couple in a highly asymmetric fashion. These features collectively provide a new mechanism for tight temporal control of the cell cycle in C. crescentus. We discuss how the procedure can serve as the basis for a general approach for probing network dynamics, which we term chemical perturbation spectroscopy (CPS).

  15. Hybrid Z-Source DC-DC Converter with ZVZCS and Power Transformer Resetting: Design, Modeling, and Fabrication

    Directory of Open Access Journals (Sweden)

    H. Torkaman

    2018-03-01

    Full Text Available This paper introduces a novel two transistors forward topology employing a z-source to achieve ZVZCS and power transformer resetting for various applications. Comparing with the forward converter, this topology has the advantage of displaying ZCS condition with an added Z-Source and no additional switches when the switches turn on, and that ZVS condition happens when the switches turn off. Duty cycle of the topology can exceed 50 percent. As a result, these converters are suitable for applications with high efficiency. In this paper, structure and properties of the topology will be discussed in details. Then the design principles will be presented. Finally, the benefits aforementioned will be approved in practice through a simple forward converter.

  16. Workplace protection of air-fed visors used in paint spraying operations.

    Science.gov (United States)

    Bolsover, J; Rajan-Sithamparanadarajah, B; Vaughan, N

    2006-04-01

    Air-fed visors are commonly used for protection against exposure to airborne isocyanates during paint spraying. Protection levels for this class of equipment are theoretically adequate, yet isocyanate sensitization in this occupation still occurs. The work reported here set out to establish the level of respiratory protection that is achieved during real paint spraying activities when air-fed visors are used. The work also examined the effects of reduced air supply flow rates on this type of respiratory protection. The workplace study highlighted common problems that occur when attempting to measure protection factors, and process and interpret the collected data. Many of the environments included in this study did not exhibit challenge concentrations high enough to reliably measure the workplace protection factor of this class of device. When detection limits are taken into consideration, the remaining field data suggest that an assigned protection factor in the region of 40 may be appropriate. When well maintained and used in accordance with the manufacturer's instructions, air-fed visors are capable of providing a good level of respiratory protection. The protection given by air-fed visors is strongly dependent on the air flow supplied to them. Laboratory measurements demonstrate that protection falls as the air supply falls. This is a gradual process and does not suddenly occur at any particular air supply flow. Observations made during the field tests indicate that there may be other activities associated with the spraying process that need to be taken into consideration when looking for sources of respiratory sensitization.

  17. Food-Growing, Air- And Water-Cleaning Module

    Science.gov (United States)

    Sauer, R. L.; Scheld, H. W.; Mafnuson, J. W.

    1988-01-01

    Apparatus produces fresh vegetables and removes pollutants from air. Hydroponic apparatus performs dual function of growing fresh vegetables and purifying air and water. Leafy vegetables rooted in granular growth medium grow in light of fluorescent lamps. Air flowing over leaves supplies carbon dioxide and receives fresh oxygen from them. Adaptable to production of food and cleaning of air and water in closed environments as in underwater research stations and submarines.

  18. Distribution and Room Air Mixing Risks to Retrofitted Homes

    Energy Technology Data Exchange (ETDEWEB)

    Burdick, A. [IBACOS, Inc., Pittsburgh, PA (United States)

    2014-12-01

    Energy efficiency upgrades reduce heating and cooling loads on a house. With enough load reduction and if the HVAC system warrants replacement, the HVAC system is often upgraded with a more efficient, lower capacity system that meets the loads of the upgraded house. For a single-story house with ceiling supply air diffusers, ducts are often removed and upgraded. For houses with ducts that are embedded in walls, the cost of demolition precludes the replacement of ducts. The challenge with the use of existing ducts is that the reduced airflow creates a decreased throw at the supply registers, and the supply air and room air do not mix well, leading to potential thermal comfort complaints. This project investigates this retrofit scenario. The issues and solutions discussed here are relevant to all climate zones, with emphasis on climates that require cooling.

  19. Breathing Air Purification for Hyperbaric Purposes, Part II

    Directory of Open Access Journals (Sweden)

    Woźniak Arkadiusz

    2015-03-01

    Full Text Available Determining the efficiency of breathing air purification for hyperbaric purposes with the use of filtration systems is of a crucial importance. However, when the Polish Navy took samples of breathing air from their own filtration plant for quality purposes, these were found to not meet the required standard. The identification of this problem imposed the need to undertake actions aimed at the elimination of the identified disruptions in the process of breathing air production, with the objective of assuring its proper quality. This study presents the results of the initial tests on the air supply sources utilised by the Polish Navy, which were carried out for the purpose of setting a proper direction of future works and implementing corrective measures in order to optimise the breathing air production process. The obtained test results will be used in a subsequent publication devoted to the assessment of the level of efficiency of air purification with the use of a multifaceted approach consisting in the utilisation of various types of air supply sources and different configurations of purification systems.

  20. Energy supply and conversion to hydrogen: how to improve the air quality in Buenos Aires city

    International Nuclear Information System (INIS)

    Venturini, Nestor R.; Bergallo, Juan E.; Corso, Hugo L.; Bolcich, Juan C.

    1998-01-01

    The regional power distribution and the market free regulation, take the companies of this sector to an increasing competition by the supply. This situation induces conceptual and technical changes, that seem oriented to a greater complementation of power menu, with consequent structuring of power chains of better economic management. In the case of electrical park, they exist power stations nonsintonizables with the fluctuations of demand, those that noticeably alter the prices to which energy can be sold. In these cases, the strategy is oriented to accumulation, to supply energy deferred in time, or in the form and place that greater rent offers. Multinational programs that illustrate these situations, with long trajectory and important resources exist, like the EUROQUEBEC, that contemplates the hydroelectricity surplus export from Canada to Europe in hydrogen form. (author)

  1. Impact of primary and secondary air supply intensity in stove on emissions of size-segregated particulate matter and carbonaceous aerosols from apple tree wood burning

    Science.gov (United States)

    Sun, Jian; Shen, Zhenxing; Zhang, Leiming; Zhang, Qian; Lei, Yali; Cao, Junji; Huang, Yu; Liu, Suixin; Zheng, Chunli; Xu, Hongmei; Liu, Hongxia; Pan, Hua; Liu, Pingping; Zhang, Renjian

    2018-04-01

    In order to assess emission factors (EF) more accurately from household biomass burning, a series of laboratory-controlled apple tree wood burning tests were conducted to measure the EFs of size-segregated particulate matter (PM) and carbonaceous aerosols. The controlled burning experiments were conducted with designed primary air (PA) and secondary air (SA) supply intensity. An optimum value of 7 m3·h- 1 was found for SA, resulting the highest modified combustion efficiency (92.4 ± 2.5%) as well as the lowest EFs of PM2.5 (0.13 ± 0.01 g·MJ- 1), OC (0.04 ± 0.03 g·MJ- 1) and EC (0.03 ± 0.01 g·MJ- 1). SA values of 7 and 10 m3·h- 1 resulted the lowest EFs for all the different PM sizes. In a test with PA of 6 m3·h- 1 and SA of 7 m3·h- 1, very low EFs were observed for OC1 (8.2%), OC2 (11.2%) and especially OP (Pyrolyzed OC) (0%, not detected), indicating nearly complete combustion under this air supply condition. Besides SA, higher PA was proved to have positive effects on PM and carbonaceous fraction emission reduction. For example, with a fixed SA of 1.5 m3·h- 1, EFs of PM2.5 decreased from 0.64 to 0.27 g·MJ- 1 when PA increased from 6 to 15 m3·h- 1 (P < 0.05). Similar reductions were also observed in EFs of OC, EC and size segregated PM.

  2. Hypothetical air ingress scenarios in advanced modular high temperature gas cooled reactors

    International Nuclear Information System (INIS)

    Kroeger, P.G.

    1988-01-01

    Considering an extremely hypothetical scenario of complete cross duct failure and unlimited air supply into the reactor vessel of a modular high temperature gas cooled ractor, it is found that the potential air inflow remains limited due to the high friction pressure drop through the active core. All incoming air will be oxidized to CO and some local external burning would be temporarily possible in such a scenario. The accident would have to continue with unlimited air supply for hundreds of hours before the core structural integrity would be jeopardized

  3. New Air Cleaning Strategies for Reduced Commercial Building Ventilation Energy ? FY11 Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Sidheswaran, Meera; Destaillats, Hugo; Cohn, Sebastian; Sullivan, Douglas P.; Fisk, William J.

    2011-10-31

    The research carried out in this project focuses on developing novel volatile organic compounds (VOCs) air cleaning technologies needed to enable energy-saving reductions in ventilation rates. we targeted a VOC air cleaning system that could enable a 50% reduction in ventilation rates. In a typical commercial HVAC system that provides a mixture of recirculated and outdoor air, a VOC air cleaner in the supply airstream must have a 15% to 20% VOC removal efficiency to counteract a 50% reduction in outdoor air supply.

  4. Reverse Engineering the Inflammatory "Clock": From Computational Modeling to Rational Resetting.

    Science.gov (United States)

    Vodovotz, Yoram

    2016-01-01

    Properly-regulated inflammation is central to homeostasis. Traumatic injury, hemorrhagic shock, septic shock, and other injury-related processes such as wound healing are associated with dysregulated inflammation. Like many biological processes, inflammation is a dynamic, complex system whose function, like that of an analog clock, cannot be discerned simply from a laundry list of its parts (data). The advent of multiplexed platforms for gathering biological data, while providing an unprecedented level of detailed information about the inflammatory response, has paradoxically also proven to be overwhelming. This problem is especially acute when the datasets involve time courses, since typical statistical analyses and data-driven modeling are geared towards single time points. Various groups have addressed this problem using dynamic approaches to data-driven and mechanistic computational modeling. These modeling tools can be thought of as the "gears" and "hands" of the "clock," and have led to insights regarding principal drivers, dynamic networks, feedbacks, and regulatory switches that characterize and perhaps regulate the inflammatory response. In parallel, mechanistic computational models have given an abstracted sense of how the inflammatory "clock" works, leading to in silico models of critically ill individuals and populations. Integrating data-driven and mechanistic modeling may point the way to a rational "resetting" of inflammation via model-driven precision medicine.

  5. Distinction between added-energy and phase-resetting mechanisms in non-invasively detected somatosensory evoked responses.

    Science.gov (United States)

    Fedele, T; Scheer, H-J; Burghoff, M; Waterstraat, G; Nikulin, V V; Curio, G

    2013-01-01

    Non-invasively recorded averaged event-related potentials (ERP) represent a convenient opportunity to investigate human brain perceptive and cognitive processes. Nevertheless, generative ERP mechanisms are still debated. Two previous approaches have been contested in the past: the added-energy model in which the response raises independently from the ongoing background activity, and the phase-reset model, based on stimulus-driven synchronization of oscillatory ongoing activity. Many criteria for the distinction of these two models have been proposed, but there is no definitive methodology to disentangle them, owing also to the limited information at the single trial level. Here, we propose a new approach combining low-noise EEG technology and multivariate decomposition techniques. We present theoretical analyses based on simulated data and identify in high-frequency somatosensory evoked responses an optimal target for the distinction between the two mechanisms.

  6. Optimizing of Make Up Air Performance for Commercial Kitchen Ventilation Improvement

    Directory of Open Access Journals (Sweden)

    Manshoor B.

    2014-07-01

    Full Text Available A commercial kitchen is a complicated environment where multiple components of a ventilation system including kitchen hood, exhaust fan, air supply, and make up air systems work together but not always in unison. For the commercial kitchen environment, make up air systems used to control the kitchen space from unwanted odor and thermal confort. Make air systems for commercial kitchen already established. However, an optimization is important to determine the most suitable make air systems and at the same time can improve the thermal comfort in the working space. In this study, a simulation work was conducted to investigate a suitable supply air velocity to optimize the make up air for kitchen ventilation system. In order to achieve the objectives, ANSYS FLUENT software (CFD was used to carry out the simulation and analysis. 3D kitchen space with 10m x 8m x 3m with air supply velocity was set to 0 m/s, 0.14 m/s, 0.28 m/s and 0.42 m/s. From the simulation work, the velocity of air flow tested which is 0.28 m/s is enough to control the heat and give an enough comfort to the working space for the size of kitchen simulated. Well implementation of the make up air in the kitchen hood can improve an air quality in the commercial kitchen and also keep the kitchen space comfortable to the workers.

  7. The economics of supplying the supplementary heat in a closed loop water source heat pump system

    International Nuclear Information System (INIS)

    Johnson, R.P.; Bartkus, V.E.; Singh, J.B.

    1993-01-01

    The paper describes the details of a research and demonstration project that will be completed in August 1992 at a healthcare facility in northeastern Pennsylvania. The purpose of the project is to compare the economics of several methods of supplying the supplementary heating in a facility served by a closed loop water source heat pump system. The systems being tested include a storage hot water tank with electric resistance heaters and three air source heat pumps that have the ability to supply the same heat during on-peak hours as well as off-peak hours. The paper compares the projected operating costs of the following: (1) Gas boiler supplying the supplementary heat. (2) Stored hot water supplying the supplementary heat which is generated and stored during off-peak hours using resistance heat on PP ampersand L's offpeak rate. (3) Stored hot water supplying the supplementary heat generated during off-peak hours using the air source heat pumps on PP ampersand L's off-peak rate. (4) Hot water generated by the air source heat pumps supplying the supplementary loop heating on PP ampersand L's general service and time-of-day electric rates. It is generally known in the HVAC industry that a closed loop water source heat pump system can provide one of the most efficient means of space conditioning to a building with high internal gains by transferring the excess heat available in one part of the building to another part of the building where it may be needed for heating. The following flow diagram depicts the relationship of the air source heat pumps with the storage tanks and the building closed water loop

  8. Cooling energy efficiency and classroom air environment of a school building operated by the heat recovery air conditioning unit

    International Nuclear Information System (INIS)

    Wang, Yang; Zhao, Fu-Yun; Kuckelkorn, Jens; Liu, Di; Liu, Li-Qun; Pan, Xiao-Chuan

    2014-01-01

    The recently-built school buildings have adopted novel heat recovery ventilator and air conditioning system. Heat recovery efficiency of the heat recovery facility and energy conservation ratio of the air conditioning unit were analytically modeled, taking the ventilation networks into account. Following that, school classroom displacement ventilation and its thermal stratification and indoor air quality indicated by the CO 2 concentration have been numerically modeled concerning the effects of delivering ventilation flow rate and supplying air temperature. Numerical results indicate that the promotion of mechanical ventilation rate can simultaneously boost the dilution of indoor air pollutants and the non-uniformity of indoor thermal and pollutant distributions. Subsequent energy performance analysis demonstrates that classroom energy demands for ventilation and cooling could be reduced with the promotion of heat recovery efficiency of the ventilation facility, and the energy conservation ratio of the air conditioning unit decreases with the increasing temperatures of supplying air. Fitting correlations of heat recovery ventilation and cooling energy conservation have been presented. - Highlights: • Low energy school buildings and classroom environment. • Heat recovery facility operating with an air conditioning unit. • Displacement ventilation influenced by the heat recovery efficiency. • Energy conservation of cooling and ventilation through heat recovery. • Enhancement of classroom environment with reduction of school building energy

  9. Resetting of Quartz OSL (optically stimulated luminescence) Signals by Frictional Heating in Experimentally Sheared Gouges at Seismic Slip Rates.

    Science.gov (United States)

    Kim, J. H.; Choi, J. H.; Chauhan, N.; Lee, S.; Hirose, T.; Ree, J. H.

    2014-12-01

    Recent studies on natural and experimental seismic faults have revealed that frictional heating plays an important role in earthquake dynamics as well as in producing mineralogical and microstructural signatures of seismic faulting. Here, we report changes in OSL signals in quartz by frictional heating in experimental fault gouges. The gouges (80% of quartz and 20% of bentonite by weight) with a thickness of 1 mm were sheared between sandstone cylinders (diameter: 25 mm) at a normal stress of 1 MPa and slip rate of 1.31 m/s. The quartz grains from a sand dune on the western coast of South Korea were sieved to select size fractions between 90 and 250 μm. The equivalent dose (De) of the undeformed quartz grains was 8.0 ± 0.3 Gy. Upon displacement, the friction abruptly increases to the 1st peak (with friction coefficient μ ≈ 0.75) followed by slip weakening. Then the fault zones show two more peak frictions (μ ≈ 0.53~0.75) and finally reach a steady-state friction (μ ≈ 0.2~0.35). The fault can be divided into three zones based grain size (thus slip rate); slip localization (SLZ), intermediate slip-rate (ISZ) and low slip-rate (LSZ) zones. SLZ develops adjacent to the moving side of the sandstone cylinder with P-foliation and shear band. The size of quartz (Dq) in ISZ and LSZ is 5-30 μm and 50-250 μm, respectively. SEM and TEM analyses indicate that the fault gouge of SLZ consists of subangular quartz clasts (Dq ≈ 3 μm) and matrix of nano-scale quartz, unidentified silicate minerals and amorphous material. The fault zones were sectioned into six layers (~160 µm thick for each layer) parallel to the fault zone boundary for OSL analyses. Quartz grains from all the layers except the one immediately adjacent to the stationary side of the sandstone cylinder show De of 'effectively' 0 Gy indicating a full resetting of OSL signals. The partial resetting of OSL signal in the layer adjacent to the stationary side of the cylinder indicates the temperature (T

  10. Air quality Performance of Ductless Personalized Ventilation in Conjunction with Displacement Ventilation: Impact of Walking Person

    DEFF Research Database (Denmark)

    Bolashikov, Zhecho Dimitrov; Lu, Pengfei; Melikov, Arsen Krikor

    2015-01-01

    The present experiment evaluates the impact of air disturbances from a walking person on inhaled air by ductless personalized ventilation (DPV) with displacement ventilation (DV), when a seated occupant is the source of pollution: bio-effluents and exhaled air. The measurements took place in a full...... and the DV supply. Pollution from feet and exhaled air by one manikin was simulated with tracer gases. Room temperature of 26 °C and 90 L/s DV supply flow rate were kept constant. Measurements under numerous combinations of DPV operation modes and supply flow rates were performed. Tracer gas concentrations...

  11. Thermal comfort and IAQ assessment of under-floor air distribution system integrated with personalized ventilation in hot and humid climate

    Energy Technology Data Exchange (ETDEWEB)

    Li, Ruixin [Department of Building, National University of Singapore (Singapore); International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark (Denmark); Sekhar, S.C. [Department of Building, National University of Singapore (Singapore); Melikov, A.K. [International Centre for Indoor Environment and Energy, Department of Civil Engineering, Technical University of Denmark (Denmark)

    2010-09-15

    The potential for improving occupants' thermal comfort with personalized ventilation (PV) system combined with under-floor air distribution (UFAD) system was explored through human response study. The hypothesis was that cold draught at feet can be reduced when relatively warm air is supplied by UFAD system and uncomfortable sensation as ''warm head'' can be reduced by the PV system providing cool and fresh outdoor air at the facial level. A study with 30 human subjects was conducted in a Field Environmental Chamber. The chamber was served by two dedicated systems - a primary air handling unit (AHU) for 100% outdoor air that is supplied through the PV air terminal devices and a secondary AHU for 100% recirculated air that is supplied through UFAD outlets. Responses of the subjects to the PV-UFAD system were collected at various room air and PV air temperature combinations. The analyses of the results obtained reveal improved acceptability of perceived air quality and improved thermal sensation with PV-UFAD in comparison with the reference case of UFAD alone or mixing ventilation with ceiling supply diffuser. The local thermal sensation at the feet was also improved when warmer UFAD supply air temperature was adopted in the PV-UFAD system. (author)

  12. Resetting translational homeostasis restores myelination in Charcot-Marie-Tooth disease type 1B mice.

    Science.gov (United States)

    D'Antonio, Maurizio; Musner, Nicolò; Scapin, Cristina; Ungaro, Daniela; Del Carro, Ubaldo; Ron, David; Feltri, M Laura; Wrabetz, Lawrence

    2013-04-08

    P0 glycoprotein is an abundant product of terminal differentiation in myelinating Schwann cells. The mutant P0S63del causes Charcot-Marie-Tooth 1B neuropathy in humans, and a very similar demyelinating neuropathy in transgenic mice. P0S63del is retained in the endoplasmic reticulum of Schwann cells, where it promotes unfolded protein stress and elicits an unfolded protein response (UPR) associated with translational attenuation. Ablation of Chop, a UPR mediator, from S63del mice completely rescues their motor deficit and reduces active demyelination by half. Here, we show that Gadd34 is a detrimental effector of CHOP that reactivates translation too aggressively in myelinating Schwann cells. Genetic or pharmacological limitation of Gadd34 function moderates translational reactivation, improves myelination in S63del nerves, and reduces accumulation of P0S63del in the ER. Resetting translational homeostasis may provide a therapeutic strategy in tissues impaired by misfolded proteins that are synthesized during terminal differentiation.

  13. An update on the MTBE supply and demand picture

    International Nuclear Information System (INIS)

    Elkins, D.R.

    1993-01-01

    The initial Clean Air Act to establish emissions standards for automobiles and light-duty trucks was passed in 1966. It was modified in 1970 and again in 1977. In 1990 it was amended to present a 20 year plan to achieve cleaner air through fuel composition and vehicle design. This paper discusses the supply and demand within the US of methyl tertiary butyl ether as an oxygenated fuel additive to gasoline to help control the ozone pollution problem

  14. Air temperature gradient in large industrial hall

    Science.gov (United States)

    Karpuk, Michał; Pełech, Aleksander; Przydróżny, Edward; Walaszczyk, Juliusz; Szczęśniak, Sylwia

    2017-11-01

    In the rooms with dominant sensible heat load, volume airflow depends on many factors incl. pre-established temperature difference between exhaust and supply airflow. As the temperature difference is getting higher, airflow volume drops down, consequently, the cost of AHU is reduced. In high industrial halls with air exhaust grids located under the ceiling additional temperature gradient above working zone should be taken into consideration. In this regard, experimental research of the vertical air temperature gradient in high industrial halls were carried out for the case of mixing ventilation system The paper presents the results of air temperature distribution measurements in high technological hall (mechanically ventilated) under significant sensible heat load conditions. The supply airflow was delivered to the hall with the help of the swirl diffusers while exhaust grids were located under the hall ceiling. Basing on the air temperature distribution measurements performed on the seven pre-established levels, air temperature gradient in the area between 2.0 and 7.0 m above the floor was calculated and analysed.

  15. Selective Interareal Synchronization through Gamma Frequency Differences and Slower-Rhythm Gamma Phase Reset.

    Science.gov (United States)

    Burwick, Thomas; Bouras, Alexandros

    2017-03-01

    The communication-through-coherence (CTC) hypothesis states that a sending group of neurons will have a particularly strong effect on a receiving group if both groups oscillate in a phase-locked ("coherent") manner (Fries, 2005 , 2015 ). Here, we consider a situation with two visual stimuli, one in the focus of attention and the other distracting, resulting in two sites of excitation at an early cortical area that project to a common site in a next area. Taking a modeler's perspective, we confirm the workings of a mechanism that was proposed by Bosman et al. ( 2012 ) in the context of providing experimental evidence for the CTC hypothesis: a slightly higher gamma frequency of the attended sending site compared to the distracting site may cause selective interareal synchronization with the receiving site if combined with a slow-rhythm gamma phase reset. We also demonstrate the relevance of a slightly lower intrinsic frequency of the receiving site for this scenario. Moreover, we discuss conditions for a transition from bottom-up to top-down driven phase locking.

  16. Advance planning for air pollution control

    Energy Technology Data Exchange (ETDEWEB)

    Brewer, G L

    1972-11-01

    An air quality management program for nitric acid plants emitting pollutants which include nitrogen oxides is proposed. The program consists of the following five phases: an inventory of the handling equipment within the plant, including the identification of potential emission sources in terms of process material balances; source testing (if required); ambient air quality measurements; emission control analysis; and the development of a complete air management plan which includes a balance between air exhausted from buildups and processes and air supplied in a controlled economical manner. Typical NOx air pollution problems associated with nitric acid plants are reviewed along with various approaches to control and by-product recovery.

  17. Performance improvement of a hybrid air conditioning system using the indirect evaporative cooler with internal baffles as a pre-cooling unit

    Directory of Open Access Journals (Sweden)

    A.E. Kabeel

    2017-12-01

    Full Text Available In the present paper, the effects of the indirect evaporative cooler with internal baffle on the performance of the hybrid air conditioning system are numerically investigated. The hybrid air conditioning system contains two indirect evaporative coolers with internal baffle, one is utilized to pre-cool the air inlet to the desiccant wheel and the other is utilized to pre-cool the supply air inlet to the room. The effects of the inlet conditions of the process and reactivation air and working air ratio on the thermal performance of the hybrid air conditioning system have been analyzed. The results of this study show that in the hybrid air conditioning system for using the indirect evaporative cooler with internal baffle as a pre-cooling unit, the supply air temperature reduced by 21% and the coefficient of performance improved by 71% as compared to previous designs of the hybrid air conditioning system at the same inlet conditions. For increasing process air inlet temperature from 25 °C to 45 °C, supply air temperature increases from 12.7 °C to 14.2 °C, thermal COP increases from 1.87 to 2.84, and supply air relative humidity increases from 76.7% to 77.4%. Also, for increasing the reactivation air inlet temperature from 70 °C to 110 °C, supply air temperature dropped from 15.9 °C to 10.9 °C, supply air relative humidity dropped from 82.7% to 71.8%, and thermal COP dropped from 4.5 to 1.7. The recommended optimal air working ratio in the indirect evaporative cooler with internal baffle should be 0.15. Keywords: Desiccant material, Solar air collector, Evaporative cooler, Internal baffles, Air conditioning

  18. A study on the treatment of radioactive liquid wastes using synthetic by air intake system

    International Nuclear Information System (INIS)

    Kim, T. G.; Lee, Y. H.; An, S. J.; Son, J. S.; Hong, K. P.

    2003-01-01

    In this study based on the mass transfer theory, experiments for the evaporation rates depending on various conditions were carried out through the operation of the existing Natural Evaporation Facility in KAERI. Evaporation media were made of the cotton and polyester. Air circulation in the facility was forced by exhausting fans. The evaporation rate and the decontamination factor were calculated by the result of experiment. The evaporation rate increased as the flow rate of air supply, the feed rate of liquid waste, and the temperature of supplied air increased. As for the humility of supplied air, the evaporation rate was getting higher as the humidity was getting lower. As the result of this study, operation conditions of the Natural Evaporation Facility are optimized as follows; The air temperature above 8C .deg., the air humidity below 70%, the air flow rate 1.14-1.47 m/sec, and the liquid waste feed rate 4.6l/hr.m 2 . The decontamination factor and the radioactivity are 5.1x10 3 and 4.7x10 -13 μCi/ml respectively, at the above mentioned optimum operation conditions. The air factor in the Dalton's equation for evaporation was determined from results of experiment on the temperature, the humidity, and the flow rate of supplied air as following; Eh=(0.0168+0.0141V)ΔH

  19. A study on the treatment of radioactive liquid wastes using synthetic by air intake system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, T. G.; Lee, Y. H.; An, S. J.; Son, J. S.; Hong, K. P. [KAERI, Taejon (Korea, Republic of)

    2003-07-01

    In this study based on the mass transfer theory, experiments for the evaporation rates depending on various conditions were carried out through the operation of the existing Natural Evaporation Facility in KAERI. Evaporation media were made of the cotton and polyester. Air circulation in the facility was forced by exhausting fans. The evaporation rate and the decontamination factor were calculated by the result of experiment. The evaporation rate increased as the flow rate of air supply, the feed rate of liquid waste, and the temperature of supplied air increased. As for the humility of supplied air, the evaporation rate was getting higher as the humidity was getting lower. As the result of this study, operation conditions of the Natural Evaporation Facility are optimized as follows; The air temperature above 8C .deg., the air humidity below 70%, the air flow rate 1.14-1.47 m/sec, and the liquid waste feed rate 4.6l/hr.m{sup 2}. The decontamination factor and the radioactivity are 5.1x10{sup 3} and 4.7x10{sup -13}{mu}Ci/ml respectively, at the above mentioned optimum operation conditions. The air factor in the Dalton's equation for evaporation was determined from results of experiment on the temperature, the humidity, and the flow rate of supplied air as following; Eh=(0.0168+0.0141V){delta}H.

  20. Optimization of recirculating laminar air flow in operating room air conditioning systems

    Directory of Open Access Journals (Sweden)

    Enver Yalcin

    2016-04-01

    Full Text Available The laminar flow air-conditioning system with 100% fresh air is used in almost all operating rooms without discrimination in Turkey. The laminar flow device which is working with 100% fresh air should be absolutely used in Type 1A operating rooms. However, there is not mandatory to use of 100% fresh air for Type 1B defined as places performed simpler operation. Compared with recirculating laminar flow, energy needs of the laminar flow with 100 % fresh air has been emerged about 40% more than re-circulated air flow. Therefore, when a recirculating laminar flow device is operated instead of laminar flow system with 100% fresh air in the Type 1B operating room, annual energy consumption will be reduced. In this study, in an operating room with recirculating laminar flow, optimal conditions have been investigated in order to obtain laminar flow form by analyzing velocity distributions at various supply velocities by using computational fluid dynamics method (CFD.

  1. Coordinating Supply Chain Distribution in the Presence of Production Disruption Risks

    Directory of Open Access Journals (Sweden)

    Xuanguo Xu

    2010-09-01

    Full Text Available With the impacts of unexpected events, production processes of supply chain system may be forced to interrupt in a certain period, which may decrease the supply capacity of manufacturer to its retailers. This paper discusses methods to distribute the limited stock in case the production disruptions occur. To ascertain a reasonable replenish sequence and quantity after the production disruption, a production disruption-oriented supply chain distribution model is offered, which can be used to minimize the negative impact of production disruption to supply chain system. And then a constraint satisfaction optimization method is established to resolve the model. Finally, validity of the model is verified with an actual application in an air-conditioner factory in China.

  2. Future butanes supply/demand

    International Nuclear Information System (INIS)

    Whitley, S.C.

    1992-01-01

    This paper graphically depicts, through in-depth supply/demand analysis, how environmental regulations can be both bad and good for an industry. In the case of n-butane, the Environmental Protection Agency (EPA) summertime gasoline volatility regulations are a culprit - threatening to ultimately destroy refinery demand for the product as a gasoline blendstock. Waiting in the wings are environmental regulations that should eventually prove to be n-butane's savior. The regulations referred to here are the Clean Air Act (CAA) of 1990's mandate for motor fuel oxygenates. The negative impact of gasoline volatility regulations on U.S. n-butane demand and the positive impact that should come from the use of n-butane as a MTBE precursor are covered. Many variables exist which make studying the effects of these environmental regulations very difficult. Over the past three years RPC Group has conducted numerous studies on n-butane supply/demand, as impacted by both EPA gasoline volatility and fuel oxygenate regulations

  3. 500 Watt Diesel Fueled TPV Portable Power Supply

    Science.gov (United States)

    Horne, W. E.; Morgan, M. D.; Sundaram, V. S.; Butcher, T.

    2003-01-01

    A test-bed 500 watt diesel fueled thermophotovoltaic (TPV) portable power supply is described. The goal of the design is a compact, rugged field portable unit weighing less than 15 pounds without fuel. The conversion efficiency goal is set at 15% fuel energy to electric energy delivered to an external load at 24 volts. A burner/recuperator system has been developed to meet the objectives of high combustion air preheat temperatures with a compact heat exchanger, low excess air operation, and high convective heat transfer rates to the silicon carbide emitter surface. The burner incorporates a air blast atomizer with 100% of the combustion air passing through the nozzle. Designed firing rate of 2900 watts at 0.07 gallons of oil per hour. This incorporates a single air supply dc motor/fan set and avoids the need for a system air compressor. The recuperator consists of three annular, concentric laminar flow passages. Heat from the combustion of the diesel fuel is both radiantly and convectively coupled to the inside wall of a cylindrical silicon carbide emitter. The outer wall of the emitter then radiates blackbody energy at the design temperature of 1400°C. The cylindrical emitter is enclosed in a quartz envelope that separates it from the photovoltaic (PV) cells. Spectral control is accomplished by a resonant mesh IR band-pass filter placed between the emitter and the PV array. The narrow band of energy transmitted by the filter is intercepted and converted to electricity by an array of GaSb PV cells. The array consists of 216 1-cm × 1-cm GaSb cells arranged into series and parallel arrays. An array of heat pipes couple the PV cell arrays to a heat exchanger which is cooled by forced air convection. A brief status of the key TPV technologies is presented followed by data characterizing the performance of the 500 watt TPV system.

  4. The investigation on compressed air quality analysis results of nuclear power plants

    International Nuclear Information System (INIS)

    Sung, K. B.; Kim, H. K.; Kim, W. S.

    2000-01-01

    The compressed air system of nuclear power plants provides pneumatic power for both operation and control of various plant equipment, tools, and instrumentation. Included in the air supply systems are the compressors, coolers, moisture separators, dryers, filters and air receiver tanks that make up the major items of equipment. The service air system provides oil-free compressed air for general plant and maintenance use and the instrument air system provides dry, oil-free, compressed air for both nonessential and essential components and instruments. NRC recommended the periodic checks on GL88-14 'Instrument air supply system problems affecting safety-related equipment'. To ensure that the quality of the instrument air is equivalent to or exceeds the requirement s of ISA-S7.3(1975), air samples are taken at every refueling outage and analyzed for moisture, oil and particulate content. The over all results are satisfied the requirements of ISA-S7.3

  5. Condensing and water supplying systems in an atomic power plant

    International Nuclear Information System (INIS)

    Shinmura, Akira.

    1975-01-01

    Object: To reduce heat loss and eliminate accumulation of drain in water supplying and heating units in an atomic power plant by providing a direct contact type drain cooler between a gland-exhauster vapor condenser and a condensing and de-salting means, the drain from each water supplying and heating unit being collected in said cooler for heating the condensed water. Structure: Condensed water from a condenser is fed by a low pressure condensing pump through an air ejector and gland-exhauster vapor condenser to the direct-contact type drain cooler and is condensed in each water supply heater. Next, it is heated by drain fed through a drain level adjuster valve and an orifice and then forced by a medium pressure condenser pump into the condensing and de-salting means. It is then supplied by a high pressure condensing pump into the successive water supply heater. (Kamimura, M.)

  6. Medium- and long-term consequences of pollution on labor supply: evidence from Indonesia

    Directory of Open Access Journals (Sweden)

    Younoh Kim

    2017-04-01

    Full Text Available Abstract We use a natural experiment in Indonesia to study the medium- and long-term effects of air pollution on labor supply. We find that exposure to air pollution reduces hours worked and while the medium-term effects are larger in magnitude, some effects do persist in the long term. More interestingly, we are able to provide some insight regarding the underlying channels that contribute to the reduced labor supply. Own health seems to be the only responsible channel in the long term, while in the medium term, a different channel based on dependent caregiving is the most important. JEL Classification: J22, Q53

  7. Air Distribution Systems and Cross-Infection Risk in the Hospital Sector

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    2012-01-01

    . A large amount of air is supplied to the room to ensure dilution of airborne infection. The paper discusses both the macroenvironment and the microenvironment. The macroenvironment is the conditions created by the air distribution system, and the microenvironment is the conditions created by the local...... flow around persons in combination with the surrounding conditions. Analyses of the flow in the room (macroenvironment) show a number of parameters that play an important role in minimising of airborne cross-infection. The air flow rate to the room must be high, and the air distribution pattern can......We protect ourselves from airborne cross-infection in our indoor environment by supplying fresh air to the room by natural or mechanical ventilation. The air is distributed in the room according to different principles as e.g. mixing ventilation, downward ventilation, displacement ventilation, etc...

  8. 46 CFR 61.35-3 - Required tests and checks.

    Science.gov (United States)

    2010-10-01

    ... heaters without water level controls) must be tested by interrupting the feed water supply. Manual reset... alarm and visible indicator must be verified. The shutdown times must be verified. (3) Fuel supply... draft loss interlock switch must be tested to ensure proper operation. The draft limit control must...

  9. Strategy Guideline. Compact Air Distribution Systems

    Energy Technology Data Exchange (ETDEWEB)

    Burdick, Arlan [IBACOS, Inc., Pittsburgh, PA (United States)

    2013-06-01

    This guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

  10. Advanced air distribution

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor

    2011-01-01

    The aim of total volume air distribution (TVAD) involves achieving uniform temperature and velocity in the occupied zone and environment designed for an average occupant. The supply of large amounts of clean and cool air are needed to maintain temperature and pollution concentration at acceptable...... levels in the entire space, leading to increased energy consumption and the use of large and costly HVAC and duct systems. The performance of desk installed PV combined with background TVAD used for room temperature control has been studied in an office building located in a hot and humid climate....... Ventilation in hospitals is essential to decrease the risk of airborne cross-infection. At present, mixing air distribution at a minimum of 12 ach is used in infection wards. Advanced air distribution has the potential to aid in achieving healthy, comfortable and productive indoor environments at levels...

  11. Temperature and Humidity Control in Air-Conditioned Buildings with lower Energy Demand and increased Indoor Air Quality

    DEFF Research Database (Denmark)

    Paul, Joachim; Martos, E. T.

    2003-01-01

    Air-conditioning is not only a matter of temperature control. Thermal comfort and good indoor air quality are mainly a matter of humidity. Human health and well being may suffer seriously from inadequate humidity and/or too low temperatures in a room. A case study involving supermarket air......%. For indoor air temperature and humidity control, the use of an ice slurry (´Binary Ice´)was compared to conventional chilled water. The use of Binary Ice instead of chilled water makes the air handling and air distribution installation much simpler, recirculation of air becomes obsolete, and a higher portion...... of ambient air can be supplied, thus improving the indoor air quality still further. Reheating of air is not necessary when using Binary Ice. The introduction of chilled air into a room requires a different type of air outlet, however. When using Binary Ice, energy savings are high for climates with low...

  12. Control device of air-fuel ratio of alcohol-gasoline mixed fuel

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Kazuo

    1987-08-19

    Concerning alcohol-gasoline mixed fuel, even the same amount of the fuel shows different air-fuel ratio depending upon alcohol concentration in the fuel, accordingly it is required to know the alcohol concentration when it is intended to make the air-fuel ratio to be the same as the predetermined ratio. Although a sensor which can detect in quick response and exactly the alcohol concentration has not been developed, the alcohol concentration in gasoline can be detected by detecting the concentration of the water in exhaust gas and many hygrometers which can detect the concentration of the water with high precision are available. With regard to an internal combustion engine equipped with a fuel supply device in order to supply alcohol-gasoline mixed fuel into an engine suction passage, this invention offers an air-fuel ratio control device to control the amount of the fuel to be supplied from the fuel supply device by detecting the concentration of alcohol in the gasoline from among the output signals of the main hygrometer and the auxiliary hygrometer. The former hygrometer to detect the concentration of the water in the exhaust gas is set in the engine exhaust gas passage and the latter is installed to detect the concentration of the water in the air. (4 figs)

  13. Users Guide to Direct Digital Control of Heating, Ventilating, and Air Conditioning Equipment,

    Science.gov (United States)

    1985-01-01

    cycles, reset, load shedding, chiller optimization , VAV fan synchronization, and optimum start/stop. The prospective buyer of a DDC system should...in Fig- ure 4. Data on setpoints , reset schedules, and event timing, such as that presented in Figure 6, are often even more difficult to find. In con...control logic, setpoint and other data are readily available. Program logic, setpoint and schedule data, and other information stored in a DDC unit

  14. Saving energy by using underfloor-air-distribution (UFAD) system in commercial buildings

    International Nuclear Information System (INIS)

    Alajmi, Ali; El-Amer, Wid

    2010-01-01

    The number of attempts by researchers to reduce building energy consumption has increased, ever since global warming became a serious issue. In this trend, a relatively new approach of air distribution, underfloor-air-distribution system (UFAD), has been widely used in new commercial buildings. This technique is simply accomplished by supplying air through a raised floor using different types of distribution configurations and outlets. In UFAD, the air is directly supplied to the occupants' area (occupied zone) causing occupants plumes and zone heat load stratify to the upper layer of the zone (unoccupied zone), which are later extracted from return points at high level. This flow pattern gives UFAD the advantage of using less energy than a conventional air-distribution system, ceiling-based air distribution (CBAD) due to lower pressure drop and lower air flow rate. This paper investigates the effectiveness of UFAD systems in commercial buildings for various types of application and at different air supply temperatures in a hot climate (The State of Kuwait). The findings show that UFAD has a significant saving of energy compared to CBAD (∼30%); in particular with high ceiling building types, as well as providing satisfactory comfort conditions for the occupants. Ultimately, more investigations should be done on conventional building heights (offices) to optimize the utilization of thermal stratification at design and operation stages.

  15. Air conditioner with three stages of indirect regeneration

    International Nuclear Information System (INIS)

    Worthington, M.N.

    1987-01-01

    An air conditioner is described comprising: a cabinet defining an internal evaporation chamber and having an air inlet and an air outlet; a heat exchanger mounted in the cabinet and defining an air movement path between the air inlet and the air outlet; means for supplying air to be cooled to the air inlet of the cabinet of movement through the air movement path of the heat exchanger in a heat exchanger relationship; air diversion means for continuously diverting some of the air emerging from the air outlet of the cabinet; and means in the evaporation chamber of the cabinet for recirculating spraying water into the chiller tube of the heat exchanger for interacting with the diverted air moving therethrough to evaporatively cool the heat exchanger

  16. Device with Complex System for Heat Utilization and Reduction of Hazardous Air Emissions

    Directory of Open Access Journals (Sweden)

    O. V. Kascheeva

    2012-01-01

    Full Text Available Investigations concern heat utilization and reduction of hazardous emissions occurring in residential buildings and accompanying operation of a great number of industrial enterprises in particular heat and power objects, and firstly, heat-generating units of small power located in densely populated residential areas without centralized heat supply.The investigation target is to reduce cost of heat produced by independent system of building heat supply, reduction of air pollution  due to hazardous gas emissions and reduction of heat pollution of the environment as a result of building ventilation system operation, ventilation of their internal and external sewerage network and higher reliability of their operation.The target is achieved because the device with complex system for heat utilization and reduction of hazardous air emissions has additionally an assembly tank for mixing flue gases, ventilation emissions and atmospheric air, heat pump. Evaporation zone of the pump is a condensator of the gas mixture and its condensate zone contains a heat supply line for a heat consumer. The line is equipped with assembling  and distributing collectors, pipeline connecting the heat supply line with the system of direct and return delivery water from a boiler house, a separator for division of liquid and gaseous mixture phases, neutralizing devices for separate reduction of concentrations of hazardous and odorous substances being released in gaseous and liquid portions of the mixture, a pipeline for periodic supply of air with higher concentration of hazardous and odorous substances in the boiler furnace. The supplied air is obtained as a result of its passing through gas filters at their regeneration when their exchange capacity is exhausted.

  17. Membrane air stripping utilizing a plate and frame configuration

    International Nuclear Information System (INIS)

    Boswell, S.T.

    1991-01-01

    Membrane air stripping has recently been proposed as a possible method to remove volatile organic chemicals (VOCs) and radon from drinking water supplies. Current and anticipated regulatory requirements, driven by health consequences, make the removal of these contaminants mandatory. This work examines the use of plate and frame membrane air stripping for the removal of VOCs and radon from a water supply. The theoretical basis of membrane air stripping and a literature review are included. The advantages of membrane air stripping versus other methods of removal, as well as the advantages of a plate and frame configuration versus a hollow fiber configuration for membrane air stripping are discussed. Multiple regression/correlation techniques are used to model mass transfer coefficients and fluid resistances. An economic evaluation is performed using the developed models. The costs of comparable membrane and packed tower air stripping systems are 4.86 cents per thousand gallons versus 4.36 cents per thousand gallons, respectively. This work indicates that plate and frame membrane air stripping may, in fact, prove to be an economical alternative to packed tower aeration and carbon adsorption for the removal of VOCs and radon

  18. Energy supply waste water treatment plant West Brabant

    Energy Technology Data Exchange (ETDEWEB)

    Poldervaart, A; Schouten, G J

    1983-09-01

    For the energy supply for the waste water treatment plant (rwzi-Bath) of the Hoogheemraadschap West-Brabant three energy sources are used: biogas of the digesters, natural gas and electricity delivered by the PZEM. For a good balance between heat/power demand and production a heat/power plant is installed. By using this system a high efficiency for the use of energy will be obtained. To save energy the oxygen concentration in the aerationtanks is automatically controlled by means of regulating the position of the air supply control valves and the capacity and number of the turbocompressors. For the oxygen controlsystem a Siemens PLC is used.

  19. Challenges of Enterprise Wide AM for Air Force Sustainment

    Science.gov (United States)

    2016-12-01

    processes for AM across the Air Force enterprise. The opportunity for cost-effective readiness is important, and using a value chain approach that takes...December 2016 Naguy is chief of the Air Force Life Cycle Management Center’s Product Support Engineering Division at Wright Patterson Air Force Base in...produc- tion that can address many current Air Force supply chain challenges. It also can reduce weight through lightweight design while potentially

  20. Thermal comfort and IAQ assessment of under-floor air distribution system integrated with personalized ventilation in hot and humid climate

    DEFF Research Database (Denmark)

    Li, Ruixin; Sekhar, S.C.; Melikov, Arsen Krikor

    2010-01-01

    The potential for improving occupants' thermal comfort with personalized ventilation (PV) system combined with under-floor air distribution (UFAD) system was explored through human response study. The hypothesis was that cold draught at feet can be reduced when relatively warm air is supplied...... of the results obtained reveal improved acceptability of perceived air quality and improved thermal sensation with PV-UFAD in comparison with the reference case of UFAD alone or mixing ventilation with ceiling supply diffuser. The local thermal sensation at the feet was also improved when warmer UFAD supply air...

  1. Changes in the referent body location and configuration may underlie human gait, as confirmed by findings of multi-muscle activity minimizations and phase resetting.

    Science.gov (United States)

    Feldman, Anatol G; Krasovsky, Tal; Baniña, Melanie C; Lamontagne, Anouk; Levin, Mindy F

    2011-04-01

    Locomotion is presumably guided by feed-forward shifts in the referent body location in the desired direction in the environment. We propose that the difference between the actual and the referent body locations is transmitted to neurons that virtually diminish this difference by appropriately changing the referent body configuration, i.e. the body posture at which muscles reach their recruitment thresholds. Muscles are activated depending on the gap between the actual and the referent body configurations resulting in a step being made to minimize this gap. This hypothesis implies that the actual and the referent leg configurations can match each other at certain phases of the gait cycle, resulting in minimization of leg muscle activity. We found several leg configurations at which EMG minima occurred, both during forward and backward gait. It was also found that the set of limb configurations associated with EMG minima can be changed by modifying the pattern of forward and backward gait. Our hypothesis predicts that, in response to perturbations of gait, the rate of shifts in the referent body location can temporarily be changed to avoid falling. The rate influences the phase of rhythmic limb movements during gait. Therefore, following the change in the rate of the referent body location, the whole gait pattern, for all four limbs, will irreversibly be shifted in time (long-lasting and global phase resetting) with only transient changes in the gait speed, swing and stance timing and cycle duration. Aside from transient changes in the duration of the swing and/or stance phase in response to perturbation, few previous studies have documented long-lasting and global phase resetting of human gait in response to perturbation. Such resetting was a robust finding in our study. By confirming the notion that feed-forward changes in the referent body location and configuration underlie human locomotion, this study solves the classical problem in the relationship between

  2. Energy Supply System for Industrial Poultry Houses

    Directory of Open Access Journals (Sweden)

    Sit M.L.

    2016-04-01

    Full Text Available The gas engine driven carbon dioxide heat pump designed for providing the heat, cold and electricity for industrial poultry house is proposed. The scheme differs from the known by using recuperative heat exchanger installed between the exhaust air duct of poultry house and heat pump evaporator and the heat curtain installed on the air duct after the evaporator. The air coming into the poultry house after the regenerative heat exchanger is supplied to the heat pump gas cooler. The heat pump produces heat of the required parameters of the input air and water for watering of poultry, space heating, etc. Heat pump compressor is driven by gas engine (GPA, by natural gas or biogas. The part of the gas-piston engine heat is used for adjusting the optimal heat pump mode and for regeneration of the absorbent in an evaporative cooler. The proposed technical solution of the above scheme provides a higher COP of the heat pump. Installing of heat curtain does not require the use of non-freezing solution to prevent icing of the air outlet of heat pump evaporator. The latter allows producing, besides electric power and heat, still cold (with the use off the adsorption-refrigerating machine and provide drying air inlet evaporative cooler (if necessary.

  3. Product carbon footprint assessment supporting the green supply chain construction in household appliance manufacturers

    Science.gov (United States)

    Chen, Jianhua; Sun, Liang; Guo, Huiting

    2017-11-01

    Supply chain carbon emission is one of the factors considered in the green supply chain management. A method was designed to support the green supply chain measures based on the carbon footprint assessment for products. A research for 3 typical household appliances carbon footprint assessment was conducted to explore using product carbon footprint assessment method to guide the green supply chain management of the manufacturers. The result could reflect the differences directions on green supply chain management of manufacturers of washing machine, air conditioner and microwave, respectively That is, the washing machine manufacturer should pay attention to the low carbon activities in upstream suppliers in highest priority, and also the promotion of product energy efficiency. The air conditioner manufacturer should pay attention to the product energy efficiency increasing in highest priority, and the improvement of refrigerant to decrease its GWP. And the microwave manufacture could only focus on the energy efficiency increasing because it contributes most of the carbon emission to its carbon footprint. Besides, the representativeness of product and the applicability of the method were also discussed. As the manufacturer could master the technical information on raw material and components of its products to conduct the product carbon footprint assessment, this method could help the manufacturer to identify the effective green supply chain measures in the preliminary stage.

  4. Operating experience of a portable thermophotovoltaic power supply

    Science.gov (United States)

    Becker, Frederick E.; Doyle, Edward F.; Shukla, Kailash

    1999-03-01

    Two configurations of man-portable thermophotovoltaic (TPV) power supplies based on Thermo Power's supported continuous fiber emitter have been designed, built, and are being tested. The systems use narrow-band, fibrous, ytterbia emitters radiating to bandgap matched silicon photovoltaic arrays with dielectric stack filters for optical energy recovery and recuperators for thermal energy recovery. The systems have been designed for operation with propane and with combustion air preheat temperatures of up to 1250 K. To operate at air preheat temperatures above the auto-ignition temperature of the fuel, a unique fuel delivery system was devised which results in the micromixing and rapid combustion of the fuel and air right in the emitter fibers. This allows the ytterbia emitter fibers to run much hotter (˜2000 K) than any of the surrounding structure.

  5. A high voltage DC switching power supply of corona discharge for ozone tube

    International Nuclear Information System (INIS)

    Ketkaew, Siseerot

    2007-08-01

    Full text: This paper presents a study of design and construction of a high voltage DC switching power supply for corona generating of ozone gas generating. This supply uses fly back converter at 3 k Vdc 30 khz and controls its operation using PWM techniques. I C TL494 is controlled of the switching. The testing of supply by putting high voltage to ozone gas tube at one-hour, the oxygen quantity 21 % of air, which ozone tube model enables ozone gas generating capacity of 95.2 mgO3/hr

  6. ACCOUNTING FOR NONUNIFORMITY OF WATER CONSUMPTION IN THE EXHAUST AIR HEAT RECLAMATION SYSTEMS FOR HOT WATER SUPPLY

    Directory of Open Access Journals (Sweden)

    Samarin Oleg Dmitrievich

    2017-03-01

    Full Text Available This article is devoted to assessment of the influence of variation of daily hot water consumption on the predicted energy effect by using heat recovery of exhaust air in typical exhaust ventilation systems of the most commonly used flat buildings during their switch to the mechanical induction for the pre-heating of water for hot water supply. It outlines the general principle of the organization of this method of energy saving and presents the basic equations of heat transfer in the heat exchanger. The article proposes a simplified method of accounting for changes in the heat transfer coefficient of air-to-water heat exchanger with fluctuations of water demand using existing dependencies for this coefficient from the rate flow of heating and heated fluid through the device. It presents observations to identify the parameters of the real changes of water consumption during the day with the main quantitative characteristics of normally distributed random variables. Calculation of thermal efficiency of the heat exchange equipment using dimensionless parameters through the number of heat transfer under the optimal opposing scheme of fluid motion is completed under conditions of variable water flow rate for the type residential building of the П3-1/16 series using the Monte Carlo method for numerical modeling of stochastic processes. The estimation of the influence of fluctuation of the current water consumption on the instantaneous thermal efficiency factor of the heat exchanger and the total energy consumption of the building is given, and it is shown that the error of said calculation using average daily parameters is within the margin of usual engineering calculation.

  7. Developing a dynamic control system for mine compressed air networks

    OpenAIRE

    Van Heerden, S.W.; Pelzer, R.; Marais, J.H.

    2014-01-01

    Mines in general, make use of compressed air systems for daily operational activities. Compressed air on mines is traditionally distributed via compressed air ring networks where multiple shafts are supplied with compressed air from an integral system. These compressed air networks make use of a number of compressors feeding the ring from various locations in the network. While these mines have sophisticated control systems to control these compressors, they are not dynamic systems. Compresso...

  8. Design of Air Ventilation System for Cargo Hold Vessels Using Solar Desiccant

    Directory of Open Access Journals (Sweden)

    Alam Baheramsyah

    2017-09-01

    Full Text Available One of the facilities and infrastructure of the vessel is the ventilation system in the cargo hold to maintain the quality. One attempt to avoid high moisture ratios is to provide a dry air supply by using desiccants. The purpose of this thesis is to design the system of air ventilation with solar desiccant by analysis the calculation with decrease air humidity ratio after passing desiccant rotor as well as fulfillment needs of heater and cooling system using heat of exhaust gas and seawater as well as fulfillment of electricity need using solar energy. From the result of analysis obtain to provide air supply in the cargo hold of 437.5 m3 / hour, the specification of rotor desiccant has a diameter of 550 mm with thickness 200 mm to decrease ratio of outside air humidity equal to 83.1% become 46.5%. Dehumidification air temperature of 47.7oC will be lowered to 35oC by using the sea water cooling media. As for the reactivation air heater requirement of 24.292 kW would be to fulfilled by utilizing the exhaust power of 498.12 kW. And for the electric power needs of the syetm is 34,488 wp will be supplied from the total solar module is 33 units with 345 wp per-capacity.

  9. 14 CFR 382.133 - What are the requirements concerning the evaluation and use of passenger-supplied electronic...

    Science.gov (United States)

    2010-01-01

    ... evaluation and use of passenger-supplied electronic devices that assist passengers with respiration in the... What are the requirements concerning the evaluation and use of passenger-supplied electronic devices... to use in the passenger cabin during air transportation, a ventilator, respirator, continuous...

  10. Self contained compressed air breathing apparatus to facilitate personnel decontamination

    International Nuclear Information System (INIS)

    McDonald, C.W.

    1963-11-01

    This report describes the modification of a Self Contained Compressed Air Breathing Apparatus to provide extended respiratory protection to grossly contaminated personnel during a decontamination period which may exceed the duration of the Breathing Apparatus air supply. (author)

  11. Self contained compressed air breathing apparatus to facilitate personnel decontamination

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, C W [Radiological and Safety Division, Atomic Energy Establishment, Winfrith, Dorchester, Dorset (United Kingdom)

    1963-11-15

    This report describes the modification of a Self Contained Compressed Air Breathing Apparatus to provide extended respiratory protection to grossly contaminated personnel during a decontamination period which may exceed the duration of the Breathing Apparatus air supply. (author)

  12. Control of the Air Supply Subsystem in a PEMFC with Balance of Plant Simulation

    Directory of Open Access Journals (Sweden)

    Alan Cruz Rojas

    2017-01-01

    Full Text Available This paper deals with the design of a control scheme for improving the air supply subsystem of a Proton Exchange Membrane Fuel Cell (PEMFC with maximum power of 65 kW. The control scheme is evaluated in a plant simulator which incorporates the balance of plant (BOP components and is built in the aspenONE® platform. The aspenONE® libraries and tools allows introducing the compressor map and sizing the heat exchangers used to conduct the reactants temperature to the operating value. The PEMFC model and an adaptive controller were programmed to create customized libraries used in the simulator. The structure of the plant control is as follows: the stoichiometric oxygen excess ratio is regulated by manipulating the compressor power, the equilibrium of the anode-cathode pressures is achieved by tracking the anode pressure with hydrogen flow manipulation; the oxygen and hydrogen temperatures are regulated in the heat exchangers, and the gas humidity control is obtained with a simplified model of the humidifier. The control scheme performance is evaluated for load changes, perturbations and parametric variations, introducing a growing current profile covering a large span of power, and a current profile derived from a standard driving speed cycle. The impact of the control scheme is advantageous, since the control objectives are accomplished and the PEMFC tolerates reasonably membrane damage that can produce active surface reduction. The simulation analysis aids to identify the safe Voltage-Current region, where the compressor works with mechanical stability.

  13. A Study of Fatigue and Performance Considerations in Air Mobility Cargo Aircrews Flying Transatlantic Missions

    National Research Council Canada - National Science Library

    Levin, Julian

    1997-01-01

    The U.S. Air Force Air Mobility Command (AMC) is responsible for movement of supplies and personnel, air refueling operations and air evacuation operations throughout the world in support of the United States' national interest...

  14. Direct Digital Control of HVAC (Heating, Ventilating, and Air Conditioning Equipment (User’s Guide)

    Science.gov (United States)

    1985-01-01

    reset, load shedding, chiller optimization , VAV fan synchronization, and optimum start/stop. The prospective buyer of a DDC system should investigate...current and accurate drawings for a conventional, built-up control system such as that illustrated in Fig- ure 4. Data on setpoints , reset schedules, and...are always available in the form of the computer program code (Figure 7). In addition to the control logic, setpoint and other data are readily

  15. Numerical simulation of ventilation air movement in partitioned offices

    Energy Technology Data Exchange (ETDEWEB)

    Plett, E.G.; Soultogiannis, A.A.; Jouini, D.B. (Department of Mechanical and Aerospace Engineering, Carleton University, Ottawa, Ontario (Canada))

    1993-01-01

    Good air quality can only be assured throughout an office complex if each workspace receives an adequate supply of ventilation air. The likelihood of achieving this situation would be increased if the building engineer had a means of easily predicting the air movement in each office configuration. A simple computer-based solution to this need is proposed. To this end, the development and validation testing of a numerical solution technique to simulate the ventilation air movement in a room or office is described. The predictions of the two-dimensional, isothermal, inviscid formulation are seen to be in good agreement with experimentally measured airflows in configurations of interest. The computer code is then used to illustrate the airflow in offices served by a single row of supply air diffusers, when partitions are used to divide the space into smaller workspaces. It is observed that the partitions distort the airflow patterns to the extent that it would be difficult to provide desirable ventilation airflows to all the workspaces formed by the partitions. (au) (26 refs.)

  16. The results of air treatment process modeling at the location of the air curtain in the air suppliers and ventilation shafts

    Directory of Open Access Journals (Sweden)

    Nikolaev Aleksandr

    2017-01-01

    Full Text Available In the existing shaft air heater installations (AHI, that heat the air for air suppliers in cold seasons, a heater channel is used. Some parts of the air from the heater go to the channel, other parts are sucked through a pithead by the general shaft pressure drawdown formed by the main ventilation installation (MVI. When this happens, a mix of two air flows leads to a shaft heat regime violation that can break pressurization of intertubular sealers. The problem of energy saving while airing underground mining enterprises is also very important. The proposed solution of both tasks due to the application of an air curtain is described in the article. In cold seasons the air treatment process should be used and it is offered to place an air curtain in the air suppliers shaft above the place of interface of the calorifer channel to a trunk in order to avoid an infiltration (suction of air through the pithead. It’s recommended to use an air curtain in a ventilation shaft because it reduces external air leaks thereby improving energy efficiency of the MVI work. During the mathematical modeling of ventilation and air preparation process (in SolidWorks Flowsimulation software package it was found out that the use of the air curtain in the air supply shaft can increase the efficiency of the AHI, and reduce the electricity consumption for ventilation in the ventilation shaft.

  17. Ventilation-air conditioner system in nuclear power plant

    International Nuclear Information System (INIS)

    Kubota, Ryuji; Sugisaki, Toshihiko.

    1989-01-01

    This invention concerns a ventilation-air conditioner system which enables, upon occurrence of accidents in a nuclear power plant, continuous operation for other adjacent nuclear power plants with no effect of accidents. Air supply system and exhaust system are operated during usual operaiton. If loss of coolants accidents should occur in an adjacent nuclear power plants, operation is switched from ventilation operaiton to the operation of re-cycling system based on an AND logic of three signals, that is, a pressure HIGH signal for the reactor container, a water level LOW signal for the reactor and a radioactivity signal of the ventilation-air conditioner sytem on the side of air supply in the nuclear power plant. Thus, nuclear reactor buildings of the nuclear power plant are from the external atmosphere. Therefore, the radioactivity HIGH signal for switching to the emergency air conditioner system of the nuclear power plant is not actuated due to the loss of coolant accidents in the adjacent nuclear power plant. In addition, since the atmospheric temperature in the nuclear reactor building can be maintained by a cooling device disposed to the recycling system, reactor shutdown can be prevented. (I.S.)

  18. Logistic indicators measurement in two assembly operations feeded by supply-chains

    Directory of Open Access Journals (Sweden)

    Thiago Morais Menezes

    2008-07-01

    Full Text Available This paper presents a methodology for the measurement of logistic indicators. The methodology was applied in two cases: a shoewear assembling manufacture and a air conditioning assembling operation, both feeded by supply-chains. The study of the assembling operation can be useful in synchronizing the supply-chain and reducing variability in order arrivals by forming an assembly buffer. The methodology applies quantitative and graphic analysis to evaluate leadtime, inventory, performance and buffer. The first case was an exploration of the model, testing and refine its quantitative part. The second case, more extended, studied, in quantitative and graphically modes, two serial processes: standard assembling of items delivered by a supply-chain and customized services. The case was discussed and the implications analyzed. With the so calculated indicators, we suggest inventory reduction in assembling and increase in customization, so the total leadtime can also be reduced. Key words:, Logistic indicators, Queues in manufacture, Manufacturing Control; Variability in Supply Chains, Supply Chain management.

  19. Air Force Journal of Logsitics. Volume 31, Number 3, Fall 2007

    National Research Council Canada - National Science Library

    2007-01-01

    ... with an assessment of the measures to determine the effectiveness of Air Force SCM transformation. The assessment provides several recommendations to improve the current suite of metrics used to manage the Air Force supply chain...

  20. Air Distribution in Rooms with a Fan-Driven Convector

    DEFF Research Database (Denmark)

    Larsen, Tine Steen; Bindels, Rob H.W.; Michalak, Lukasz

    2007-01-01

    the acceptable conditions for the supplyJlow rate and the temperature difference for the convector system. The paper shows that the air distribution from the convector results in comfortable velocity and temperature conditions with a heat load of 210 W. This is also confirmed by the draft ratings, which in all...... coming from the dijfuser is partly controlled by the momentum flow and partly from gravity forces, where the thermal load in the room and the temperature difference between room air and supply air affect the airflow from the convector. The convector system was tested in the same test room in which many......Experiments with a fan-driven convector used for both heating and cooling are de.scribed in this paper. Only the cooling situation is considered. The convector is positioned in the upper corner ofthe room, and from there the cold air is let out through the device along the ceiling. The airflow...

  1. Solar thermal energy / exhaust air heat pump / wood pellet furnace for a sustainable heat supply of low energy buildings in older buildings; Solarthermie / Abluft-Waermepumpe / Pelletofen. Kombisysteme zur nachhaltigen Waermeversorgung von Niedrigenergiehaeusern im Gebaeudebestand

    Energy Technology Data Exchange (ETDEWEB)

    Diefenbach, Nikolaus; Born, Rolf [Institut Wohnen und Umwelt GmbH, Darmstadt (Germany); Staerz, Norbert [Ingenieurbuero inPlan, Pfungstadt (Germany)

    2009-11-13

    The research project under consideration reports on combination systems for a sustainable heat supply for low-energy buildings in older building. For this, a central and decentralized system configuration consisting of solar thermal energy, exhaust air heat pump and wood pellet furnace are presented. Solutions for an interaction of these three heat suppliers in one plant are designated regarding the control strategy. The fundamentals of the computerized simulations for the central and decentralized system are presented. A cost estimate with both variants of the combination system as well as a comparison with conventional energy-saving heat supply systems follow.

  2. Residential Pre-Cooling: Mechanical Cooling and Air-Side Economizers:

    OpenAIRE

    Turner, William J.N; Walker, Iain S.; Roux, Jordan

    2012-01-01

    This study used an advanced airflow, energy and humidity modeling tool to evaluate residential air-side economizers and mechanical pre-cooling strategies using the air conditioner, in all US DOE Climate Zones for a typical new home with ASHRAE Standard 62.2 compliant ventilation. A residential air-side economizer is a large supply fan used for night ventilation. Mechanical pre-cooling used the building air conditioner operating at lower than usual set before the peak demand period. The simula...

  3. Performance improvement of a cross-flow hydro turbine by air layer effect

    International Nuclear Information System (INIS)

    Choi, Y D; Yoon, H Y; Inagaki, M; Ooike, S; Kim, Y J; Lee, Y H

    2010-01-01

    The purpose of this study is not only to investigate the effects of air layer in the turbine chamber on the performance and internal flow of the cross-flow turbine, but also to suggest a newly developed air supply method. Field test is performed in order to measure the output power of the turbine by a new air supply method. CFD analysis on the performance and internal flow of the turbine is conducted by an unsteady state calculation using a two-phase flow model in order to embody the air layer effect on the turbine performance effectively.The result shows that air layer effect on the performance of the turbine is considerable. The air layer located in the turbine runner passage plays the role of preventing a shock loss at the runner axis and suppressing a recirculation flow in the runner. The location of air suction hole on the chamber wall is very important factor for the performance improvement. Moreover, the ratio between air from suction pipe and water from turbine inlet is also significant factor of the turbine performance.

  4. Assessment of domestic water supply situation in rural communities ...

    African Journals Online (AJOL)

    Water is needed by man for the sustenance of life and it is the second most important natural resource used by man after the air were breathe. Man survives longer without food than without water. The socio-economic development of man is determined partly by the availability of water. The supply of safe pipe-borne water in ...

  5. Operational test procedure for Bldg 241-A-701 air compressor

    International Nuclear Information System (INIS)

    Desantis, G.N.

    1995-01-01

    This document is an Operability Test Procedure (OTP) which will verify and record that the 241-A-701 air compressor and associated equipment operates within their intended design parameters. The activities defined in this OTP will be performed to ensure the daily operation of the new compressed air system can be reliable and efficient. The Compressed Air System (CAS) for 241-A-701 supplies process and instrument air to the A, AX, AY, and AZ tank farms. The primary use of the CAS is for tank farms instrumentation, air operated valves, and air lift circulators

  6. Poster Puzzler Solution: Taking in Air | Poster

    Science.gov (United States)

    The current Poster Puzzler image shows the top of Building 560, where a new supply air handler was recently installed by Facilities Maintenance and Engineering (FME) staff, as part of lab renovations in wing 1, floor 1. FME staff enlarged the attic of the building to make space for the air handler. Building 560, the largest building at the NCI at Frederick campus, houses about

  7. Performance calculations for battery power supplies as laboratory research tools

    International Nuclear Information System (INIS)

    Scanlon, J.J.; Rolader, G.E.; Jamison, K.A.; Petresky, H.

    1991-01-01

    Electromagnetic Launcher (EML) research at the Air Force Armament Laboratory, Hypervelocity Launcher Branch (AFATL/SAH), Eglin AFB, has focused on developing the technologies required for repetitively launching several kilogram payloads to high velocities. Previous AFATL/SAH experiments have been limited by the available power supply resulting in small muzzle energies on the order of 100's of kJ. In an effort to advance the development of EML's, AFATL/SAH has designed and constructed a battery power supply (BPS) capable of providing several mega-Amperes of current for several seconds. This system consists of six modules each containing 2288 automotive batteries which may be connected in two different series - parallel arrangements. In this paper the authors define the electrical characteristics of the AFATL Battery Power supply at the component level

  8. Oklahoma Study of Educator Supply and Demand: Trends and Projections

    Science.gov (United States)

    Berg-Jacobson, Alex; Levin, Jesse

    2015-01-01

    In June 2014, the Oklahoma State Regents of Higher Education (OSRHE) commissioned American Institutes for Research (AIR) to conduct a study to better understand both historical and future predicted trends of educator supply and demand across Oklahoma. OSRHE commissioned the study in partnership with the Oklahoma Commission for Teacher Preparation…

  9. Diffuse Ceiling Inlet Systems and the Room Air Distribution

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Jensen, Rasmus Lund; Rong, Li

    2010-01-01

    A diffuse ceiling inlet system is an air distribution system which is supplying the air through the whole ceiling. The system can remove a large heat load without creating draught in the room. The paper describes measurements in the case of both cooling and heating, and CFD predictions are given...

  10. The Performance of Diffuse Ceiling Inlet and other Room Air Distribution Systems

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Jakubowska, Ewa

    2009-01-01

    The paper analyses different room air distribution systems, and describes a design chart which can be used for the evaluation of variables as air quality, air velocity and temperature gradient as a function of flow rate and temperature difference in the supply system. The design chart can also be...

  11. Thermal decay in underfloor air distribution (UFAD) systems: Fundamentals and influence on system performance

    International Nuclear Information System (INIS)

    Lee, Kwang Ho; Schiavon, Stefano; Bauman, Fred; Webster, Tom

    2012-01-01

    Graphical abstract: Surface heat transfer breakdown for an underfloor air distribution (UFAD) system supply plenum. Highlights: ► Thermal decay of a UFAD system is considerable (annual median = 3.7 K). ► Thermal decay is driven by heat transfer through both the concrete slab and the raised floor. ► Thermal decay may lead to higher airflow rates and increased fan and chiller energy consumption. -- Abstract: Underfloor air distribution (UFAD) is a mechanical ventilation strategy in which the conditioned air is primarily delivered to the zone from a pressurized plenum through floor mounted diffusers. Compared to conventional overhead (OH) mixing systems, UFAD has several potential advantages, such as improved thermal comfort and indoor air quality (IAQ), layout flexibility, reduced life cycle costs and improved energy efficiency in suitable climates. In ducted OH systems designers have reasonably accurate control of the diffuser supply temperature, while in UFAD this temperature is difficult to predict due to the heat gain of the conditioned air in the supply plenum. The increase in temperature between the air entering the plenum and air leaving through a diffuser is known as thermal decay. In this study, the detailed whole-building energy simulation program, EnergyPlus, was used to explain the fundamentals of thermal decay, to investigate its influence on energy consumption and to study the parameters that affect thermal decay. It turns out that the temperature rise is considerable (annual median = 3.7 K, with 50% of the values between 2.4 and 4.7 K based on annual simulations). Compared to an idealized simulated UFAD case with no thermal decay, elevated diffuser air temperatures can lead to higher supply airflow rate and increased fan and chiller energy consumption. The thermal decay in summer is higher than in winter and it also depends on the climate. The ground floor with a slab on grade has less temperature rise compared to middle and top floors. An

  12. Transgenerational inheritance or resetting of stress-induced epigenetic modifications: two sides of the same coin.

    Science.gov (United States)

    Tricker, Penny J

    2015-01-01

    The transgenerational inheritance of stress-induced epigenetic modifications is still controversial. Despite several examples of defense "priming" and induced genetic rearrangements, the involvement and persistence of transgenerational epigenetic modifications is not known to be general. Here I argue that non-transmission of epigenetic marks through meiosis may be regarded as an epigenetic modification in itself, and that we should understand the implications for plant evolution in the context of both selection for and selection against transgenerational epigenetic memory. Recent data suggest that both epigenetic inheritance and resetting are mechanistically directed and targeted. Stress-induced epigenetic modifications may buffer against DNA sequence-based evolution to maintain plasticity, or may form part of plasticity's adaptive potential. To date we have tended to concentrate on the question of whether and for how long epigenetic memory persists. I argue that we should now re-direct our question to investigate the differences between where it persists and where it does not, to understand the higher order evolutionary methods in play and their contribution.

  13. Transgenerational inheritance or resetting of stress-induced epigenetic modifications: two sides of the same coin.

    Directory of Open Access Journals (Sweden)

    Penny J Tricker

    2015-09-01

    Full Text Available The transgenerational inheritance of stress-induced epigenetic modifications is still controversial. Despite several examples of defence ‘priming’ and induced genetic rearrangements, the involvement and persistence of transgenerational epigenetic modifications is not known to be general. Here I argue that non-transmission of epigenetic marks through meiosis may be regarded as an epigenetic modification in itself, and that we should understand the implications for plant evolution in the context of both selection for and selection against transgenerational epigenetic memory. Recent data suggest that both epigenetic inheritance and resetting are mechanistically directed and targeted. Stress-induced epigenetic modifications may buffer against DNA sequence-based evolution to maintain plasticity, or may form part of plasticity’s adaptive potential. To date we have tended to concentrate on the question of whether and for how long epigenetic memory persists. I argue that we should now re-direct our question to investigate the differences between where it persists and where it does not, to understand the higher order evolutionary methods in play and their contribution.

  14. Life-cycle air emissions from PV power systems

    International Nuclear Information System (INIS)

    Watt, M.E.; Johnson, A.J.; Outhred, H.R.; Ellis, M.

    1998-01-01

    This paper addresses the air emission of grid supply versus grid-connected and off-grid photovoltaic power generation, using the framework of life-cycle assessment, in the contents of rural household energy supply in Australia. Emissions of carbon dioxide, sulphur dioxde and nitrous oxides are calculated for the three life-cycle stages of manufacture, use and disposal. Sensitivities to materials and data inputs, as well as to component efficiencies, lifetimes and sizing are discussed. For each supply option, demand management options, including insulation and appliance choice, and the substitution of solar heating or bottled gas for electricity are considered. The best option in all cases, in terms of life-cycle air emissions, is a grid-connected photovoltaic system used to supply an energy-efficient household with a mix of solar, gas and electric appliances. However, in financial terms, with current Australian energy prices, this option represents a high capital and life-cycle costs. Additionally, for the grid options, electricity costs do not significantly disadvantage the high demand scenarios. Both results provide a clear illustration of current Australian energy-pricing policies being in conflict with long-term environmental sustainability. (Author)

  15. Qualitative models and experimental investigation of chaotic NOR gates and set/reset flip-flops

    Science.gov (United States)

    Rahman, Aminur; Jordan, Ian; Blackmore, Denis

    2018-01-01

    It has been observed through experiments and SPICE simulations that logical circuits based upon Chua's circuit exhibit complex dynamical behaviour. This behaviour can be used to design analogues of more complex logic families and some properties can be exploited for electronics applications. Some of these circuits have been modelled as systems of ordinary differential equations. However, as the number of components in newer circuits increases so does the complexity. This renders continuous dynamical systems models impractical and necessitates new modelling techniques. In recent years, some discrete dynamical models have been developed using various simplifying assumptions. To create a robust modelling framework for chaotic logical circuits, we developed both deterministic and stochastic discrete dynamical models, which exploit the natural recurrence behaviour, for two chaotic NOR gates and a chaotic set/reset flip-flop. This work presents a complete applied mathematical investigation of logical circuits. Experiments on our own designs of the above circuits are modelled and the models are rigorously analysed and simulated showing surprisingly close qualitative agreement with the experiments. Furthermore, the models are designed to accommodate dynamics of similarly designed circuits. This will allow researchers to develop ever more complex chaotic logical circuits with a simple modelling framework.

  16. The thermodynamics of direct air capture of carbon dioxide

    International Nuclear Information System (INIS)

    Lackner, Klaus S.

    2013-01-01

    An analysis of thermodynamic constraints shows that the low concentration of carbon dioxide in ambient air does not pose stringent limits on air capture economics. The thermodynamic energy requirement is small even using an irreversible sorbent-based process. A comparison to flue gas scrubbing suggests that the additional energy requirement is small and can be supplied with low-cost energy. In general, the free energy expended in the regeneration of a sorbent will exceed the free energy of mixing, as absorption is usually not reversible. The irreversibility, which grows with the depth of scrubbing, tends to affect flue gas scrubbing more than air capture which can successfully operate while extracting only a small fraction of the carbon dioxide available in air. This is reflected in a significantly lower theoretical thermodynamic efficiency for a single stage flue gas scrubber than for an air capture device, but low carbon dioxide concentration in air still results in a larger energy demand for air capture. The energy required for capturing carbon dioxide from air could be delivered in various ways. I analyze a thermal swing and also a previously described moisture swing which is driven by the evaporation of water. While the total amount of heat supplied for sorbent regeneration in a thermal swing, in accordance with Carnot's principle, exceeds the total free energy requirement, the additional free energy required as one moves from flue gas scrubbing to air capture can be paid with an amount of additional low grade heat that equals the additional free energy requirement. Carnot's principle remains satisfied because the entire heat supplied, not just the additional amount, must be delivered at a slightly higher temperature. Whether the system is driven by water evaporation or by low grade heat, the cost of the thermodynamically-required energy can be as small as $1 to $2 per metric ton of carbon dioxide. Thermodynamics does not pose a practical constraint on the

  17. Effect of air humidification on the sick building syndrome and perceived indoor air quality in hospitals: a four month longitudinal study.

    Science.gov (United States)

    Nordström, K; Norbäck, D; Akselsson, R

    1994-01-01

    The sensation of dryness and irritation is essential in the sick building syndrome (SBS), and such symptoms are common in both office and hospital employees. In Scandinavia, the indoor relative humidity in well ventilated buildings is usually in the range 10-35% in winter. The aim of this study was to evaluate the effect of steam air humidification on SBS and perceived air quality during the heating season. The study base consisted of a dynamic population of 104 hospital employees, working in four new and well ventilated geriatric hospital units in southern Sweden. Air humidification raised the relative air humidity to 40-45% in two units during a four months period, whereas the other two units served as controls with relative humidity from 25-35%. Symptoms and perceived indoor air quality were measured before and after the study period by a standardised self administered questionnaire. The technical measurements comprised room temperature, air humidity, static electricity, exhaust air flow, aerosols, microorganisms, and volatile organic compounds in the air. The most pronounced effect of the humidification was a significant decrease of the sensation of air dryness, static electricity, and airway symptoms. After four months of air humidification during the heating season, 24% reported a weekly sensation of dryness in humidified units, compared with 73% in controls. No significant changes in symptoms of SBS or perceived air quality over time were found in the control group. The room temperature in all units was between 21-23 degrees C, and no significant effect of air humidification on the air concentration of aerosols or volatile organic compounds was found. No growth of microorganisms was found in the supply air ducts, and no legionella bacteria were found in the supply water of the humidifier. Air humidification, however, significantly reduced the measured personal exposure to static electricity. It is concluded that air humidification during the heating season

  18. Microfabricated Air-core Toroidal Inductor In Very High Frequency Power Converters

    DEFF Research Database (Denmark)

    Lê Thanh, Hoà; Nour, Yasser; Han, Anpan

    2018-01-01

    Miniaturization of power supplies is required for future intelligent electronic systems e.g. internet of things devices. Inductors play an essential role, and they are by far the most bulky and expensive components in power supplies. This paper presents a miniaturized microelectromechanical systems...... (MEMS) inductor and its performance in a very high frequency (VHF) power converter. The MEMS inductor is a siliconembedded air-core toroidal inductor, and it is constructed with through-silicon vias, suspended copper windings, silicon fixtures, and a silicon support die. The air-core inductors...

  19. Massachusetts Study of Teacher Supply and Demand: Trends and Projections

    Science.gov (United States)

    Levin, Jesse; Berg-Jacobson, Alex; Atchison, Drew; Lee, Katelyn; Vontsolos, Emily

    2015-01-01

    In April 2015, the Massachusetts Department of Elementary and Secondary Education (ESE) commissioned American Institutes for Research (AIR) to develop a comprehensive set of 10-year projections of teacher supply and demand in order to inform planning for future workforce needs. This included state-level projections both in the aggregate, as well…

  20. Air Leakage and Air Transfer Between Garage and Living Space

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, A.

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

  1. The impact of temperature on mean local air age and thermal comfort in a stratum ventilated office

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Lin; Lin, Zhang; Yao, Ting [Building Energy and Environmental Technology Research Unit, School of Energy and Environment and Division of Building Science and Technology, City University of Hong Kong, Hong Kong SAR (China); Liu, Jing; Wang, Qiuwang [State Key Lab of Multiphase Flow in Power Engineering, Xi' an Jiaotong University, Xi' an, 710049 (China)

    2011-02-15

    The influence of the supply air temperature on the mean local air age and thermal comfort of a typical individual office under stratum ventilation is investigated by a numerical method, which is validated by an experiment carried out by the authors. The results show that for an office, when the supply air temperature is increased from 19 C to 21 C, the corresponding mean occupied zone temperature rises from 24.5 C to 26.5 C. The inhaled air quality for the occupant is improved when supply air temperature rises from 19 C to 21 C. Also, the thermal comfort indices (predicted mean vote or PMV, predicted percentage of dissatisfied or PPD and predicted dissatisfied or PD) fulfill the requirements of ISO 7730 and CR 175 1998. For summer cooling operation, stratum ventilation may offer a feasible solution to elevated indoor temperatures, which are recommended by several governments in East Asia. (author)

  2. Ecosystem service markets 101: supply and demand for nature

    Science.gov (United States)

    Rhonda Mazza; Jeff Kline; Trista Patterson

    2012-01-01

    Establishing markets for ecosystem services—the benefits that nature provides, such as clean air, water, and wildlife habitat—has gained traction in some circles as a way to finance the conservation of these public goods. Market influences on supply and demand work in tandem to encourage ecosystem protection. Jeff Kline and Trista Patterson, scientists with the...

  3. Requirements of office air conditioners. Pt. 1

    Energy Technology Data Exchange (ETDEWEB)

    Radtke, W

    1988-01-01

    New building designs and experiences gained in the past are reponsible for the considerable changes the requirements of air conditioners have gone through in recent years. Details are given on an exemplary air conditioning system designed for the Colonia Insurances building complex located in the city of Cologne. The ventilation requirements and hygienic conditions set out for air conditioned rooms call for outside air supplies, the careful selection of air intakes, and the filtering of intake air. Details are given on the efficiency and limits of combined natural window ventilation/artificial ventilation systems, the influence of window types, and the influence of building structures. The pressure conditions to be expected for larger building complexes in the case of natural ventilation should be assessed with the help of models put to wind tunnel tests.

  4. Prize-winning energy conservation house equipped with air collectors at Bad Vilbel

    Energy Technology Data Exchange (ETDEWEB)

    Urbanek, A.

    An energy conservation house is the winner out of a total of 60 designs and is displayed at the prefabricated-house exhibition at Bad Vilbel. Similar to Socrates' building in antiquity, this house constitutes a triangle both perpendicularly and horizontally opening its largest possible surface to the South. Any 'residual heat' needed for the Northern roof planted over, is supplied by the air collectors either directly or by means of a high-performance heat pump via heating of the controlled feed air through a novel air floor heating installation while removing energy, too, from the exhaust air through heat recovery. In a survey supported by photos of models and buildings, lay-out plans and connector diagrams of energy supply, technical details of the heat protection concept (aerated concrete for walls, ceilings, roofing structures) and the energy concept with air collectors are described along with a discussion of heat pump operation, the novel air floor heating system and the solar cycle control system. Every room has a miniature heat exchanger allocated in the central unit so that re-heated air can be demanded via the separate room thermostat depending on reflow-air temperature.

  5. Advanced Strategy Guideline: Air Distribution Basics and Duct Design

    Energy Technology Data Exchange (ETDEWEB)

    Burdick, A.

    2011-12-01

    This report discusses considerations for designing an air distribution system for an energy efficient house that requires less air volume to condition the space. Considering the HVAC system early in the design process will allow adequate space for equipment and ductwork and can result in cost savings. Principles discussed that will maximize occupant comfort include delivery of the proper amount of conditioned air for appropriate temperature mixing and uniformity without drafts, minimization of system noise, the impacts of pressure loss, efficient return air duct design, and supply air outlet placement, as well as duct layout, materials, and sizing.

  6. Transient Air-Water Flow and Air Demand following an Opening Outlet Gate

    Directory of Open Access Journals (Sweden)

    James Yang

    2018-01-01

    Full Text Available In Sweden, the dam-safety guidelines call for an overhaul of many existing bottom outlets. During the opening of an outlet gate, understanding the transient air-water flow is essential for its safe operation, especially under submerged tailwater conditions. Three-dimensional CFD simulations are undertaken to examine air-water flow behaviors at both free and submerged outflows. The gate, hoisted by wire ropes and powered by AC, opens at a constant speed. A mesh is adapted to follow the gate movement. At the free outflow, the CFD simulations and model tests agree well in terms of outlet discharge capacity. Larger air vents lead to more air supply; the increment becomes, however, limited if the vent area is larger than 10 m2. At the submerged outflow, a hydraulic jump builds up in the conduit when the gate reaches approximately 45% of its full opening. The discharge is affected by the tailwater and slightly by the flow with the hydraulic jump. The flow features strong turbulent mixing of air and water, with build-up and break-up of air pockets and collisions of defragmented water bodies. The air demand rate is several times as much as required by steady-state hydraulic jump with free surface.

  7. Unintended inhalation of nitric oxide by contamination of compressed air: physiologic effects and interference with intended nitric oxide inhalation in acute lung injury.

    Science.gov (United States)

    Benzing, A; Loop, T; Mols, G; Geiger, K

    1999-10-01

    Compressed air from a hospital's central gas supply may contain nitric oxide as a result of air pollution. Inhaled nitric oxide may increase arterial oxygen tension and decrease pulmonary vascular resistance in patients with acute lung injury and acute respiratory distress syndrome. Therefore, the authors wanted to determine whether unintentional nitric oxide inhalation by contamination of compressed air influences arterial oxygen tension and pulmonary vascular resistance and interferes with the therapeutic use of nitric oxide. Nitric oxide concentrations in the compressed air of a university hospital were measured continuously by chemiluminescence during two periods (4 and 2 weeks). The effects of unintended nitric oxide inhalation on arterial oxygen tension (n = 15) and on pulmonary vascular resistance (n = 9) were measured in patients with acute lung injury and acute respiratory distress syndrome by changing the source of compressed air of the ventilator from the hospital's central gas supply to a nitric oxide-free gas tank containing compressed air. In five of these patients, the effects of an additional inhalation of 5 ppm nitric oxide were evaluated. During working days, compressed air of the hospital's central gas supply contained clinically effective nitric oxide concentrations (> 80 parts per billion) during 40% of the time. Change to gas tank-supplied nitric oxide-free compressed air decreased the arterial oxygen tension by 10% and increased pulmonary vascular resistance by 13%. The addition of 5 ppm nitric oxide had a minimal effect on arterial oxygen tension and pulmonary vascular resistance when added to hospital-supplied compressed air but improved both when added to tank-supplied compressed air. Unintended inhalation of nitric oxide increases arterial oxygen tension and decreases pulmonary vascular resistance in patients with acute lung injury and acute respiratory distress syndrome. The unintended nitric oxide inhalation interferes with the

  8. Fuzzy logic speed control for the engine of an air-powered vehicle

    OpenAIRE

    Qihui Yu; Yan Shi; Maolin Cai; Weiqing Xu

    2016-01-01

    To improve the condition of air and eliminate exhaust gas pollution, this article proposes a compressed air power system. Instead of an internal combustion engine, the automobile is equipped with a compressed air engine, which transforms the energy of compressed air into mechanical motion energy. A prototype was built, and the compressed air engine was tested on an experimental platform. The output torque and energy efficiency were obtained from experimental results. When the supply pressure ...

  9. Connection of control circuits of machine for automatic measurement of radioactive samples

    International Nuclear Information System (INIS)

    Vorlicek, J.

    1984-01-01

    A windowless through-flow gas detector is used for measurement. The automatic machine is controlled by four flip-flops defining the following states: the dish replacement in the measuring space, washing, measurement, measured value print-out, and resetting. The first and second outputs of the first, second and third flip-flops are connected to six inputs of a block whose four outputs provide counter reset and stop-watch reset, washing, measurement, and print-out. Such machine control eliminates measurement errors by disabling sample measurement until air is removed from the measurement space, introduced on an unwashed dish or on several dishes passed under the detector. The elimination of this error is also guaranteed in manual operation. (M.D.)

  10. Indoor air pollution

    International Nuclear Information System (INIS)

    Qureshi, I.H.

    2001-01-01

    Indoor air pollution is a potential risk to human health. Prolonged exposure to indoor pollutants may cause various infectious, allergic and other diseases. Indoor pollutants can emanate from a broad array of internal and external sources. Internal sources include building and furnishing materials, consumer and commercial products, office equipment, micro-organisms, pesticides and human occupants activities. External sources include soil, water supplies and outside makeup air. The main indoor air pollutants of concern are inorganic gases, formaldehyde and other volatile organic compounds, pesticides, radon and its daughters, particulates and microbes. The magnitude of human exposure to indoor pollutants can be estimated or predicted with the help of mathematical models which have been developed using the data from source emission testing and field monitoring of pollutants. In order to minimize human exposure to indoor pollutants, many countries have formulated guidelines / standards for the maximum permissible levels of main pollutants. Acceptable indoor air quality can be achieved by controlling indoor pollution sources and by effective ventilation system for removal of indoor pollutants. (author)

  11. Quantum reversibility is relative, or does a quantum measurement reset initial conditions?

    Science.gov (United States)

    Zurek, Wojciech H

    2018-07-13

    I compare the role of the information in classical and quantum dynamics by examining the relation between information flows in measurements and the ability of observers to reverse evolutions. I show that in the Newtonian dynamics reversibility is unaffected by the observer's retention of the information about the measurement outcome. By contrast-even though quantum dynamics is unitary, hence, reversible-reversing quantum evolution that led to a measurement becomes, in principle, impossible for an observer who keeps the record of its outcome. Thus, quantum irreversibility can result from the information gain rather than just its loss-rather than just an increase of the (von Neumann) entropy. Recording of the outcome of the measurement resets, in effect, initial conditions within the observer's (branch of) the Universe. Nevertheless, I also show that the observer's friend-an agent who knows what measurement was successfully carried out and can confirm that the observer knows the outcome but resists his curiosity and does not find out the result-can, in principle, undo the measurement. This relativity of quantum reversibility sheds new light on the origin of the arrow of time and elucidates the role of information in classical and quantum physics. Quantum discord appears as a natural measure of the extent to which dissemination of information about the outcome affects the ability to reverse the measurement.This article is part of a discussion meeting issue 'Foundations of quantum mechanics and their impact on contemporary society'. © 2018 The Author(s).

  12. Distribution and Room Air Mixing Risks to Retrofitted Homes

    Energy Technology Data Exchange (ETDEWEB)

    Burdick, A. [IBACOS, Inc., Pittsburgh, PA (United States)

    2014-12-01

    An energy efficiency upgrade reduces a home’s heating and cooling load. If the load reduction is great enough and the heating, ventilation, and air conditioning system warrants replacement, that system is often upgraded with a more efficient, lower capacity system that meets the load of the upgraded house. For a single-story house with floor supply air diffusers, the ducts often are removed and upgraded. For houses with ducts that are embedded in walls, the cost of demolition precludes the replacement of ducts. The challenge with the use of existing ducts is that the reduced airflow creates a decreased throw at the supply registers, and the supply air and room air do not mix well, leading to potential thermal comfort complaints. This project investigates this retrofit scenario. The issues and solutions discussed here are relevant to all climate zones, with emphasis on climates that require cooling. In this project, IBACOS performed load calculations for a two-story 1960s house and characterized duct sizes and layouts based on industry “rules of thumb” (Herk et al. 2014). The team performed duct-sizing calculations for unaltered ducts and post-retrofit airflows and examined airflow velocities and pressure changes with respect to various factors. The team then used a mocked-up duct and register setup to measure the characteristics of isothermal air—to reduce the effects of buoyancy from the observations—passing through the duct and leaving the register.

  13. The Air Force Critical Care Air Transport Team (CCATT): Using the Estimating Supplies Program (ESP) to Validate Clinical Requirements

    Science.gov (United States)

    2005-04-05

    Disease, Severe. 0249 Peptic Ulcer , Gastric or Duodenal, Penetrating and/or Perforating . 0250 Peptic Ulcer , Gastric or Duodenal, Uncomplicated. 0251...in US Air Force (USAF) Allowance Standard (AS) development and management . The Critical Care Air Transport Team (CCATT) Unit Type Code (UTC) AS was...tasks enabling the management of the critically ill or injured en route to the appropriate level of care (LOC) or medical treatment facility (MTF

  14. Innovations in managing demand and supply of energy

    Energy Technology Data Exchange (ETDEWEB)

    Loughborough, K. [Enwave District Energy, Toronto, ON (Canada)

    2004-07-01

    Enwave District Energy Ltd. is one of North America's largest district energy system manufacturers which provides outsourced heating and cooling to more than 130 major buildings in downtown Toronto. This presentation described innovations in managing the supply and demand of energy, and provided several viewgraphs depicting service heating, district cooling, and the district energy distribution network in Toronto. One of Enwave's greatest innovations is the deep lake water cooling (DLWC) district cooling system. The $175 million capital joint infrastructure project which began in June 2002 will be on line in 2004. The district cooling system represents the largest renewable energy project in Canada with a total cooling capacity of 52,000 tons. The system relies on DLWC and conventional chillers. DLWC uses naturally cold water from Lake Ontario. The coldness from the water is used to provide air conditioning to the buildings in Toronto. The benefits include 75 per cent reduced energy use, the elimination of ozone depleting refrigerants, and the use of a renewable resource for providing a stable cooling supply. Emissions of carbon dioxide, nitrogen oxides and oxides of sulphur are also reduced. The benefits to the city include a reduced strain on the electricity infrastructure, cleaner air and improved health. tabs., figs.

  15. Computer Model to Estimate Reliability Engineering for Air Conditioning Systems

    International Nuclear Information System (INIS)

    Afrah Al-Bossly, A.; El-Berry, A.; El-Berry, A.

    2012-01-01

    Reliability engineering is used to predict the performance and optimize design and maintenance of air conditioning systems. Air conditioning systems are expose to a number of failures. The failures of an air conditioner such as turn on, loss of air conditioner cooling capacity, reduced air conditioning output temperatures, loss of cool air supply and loss of air flow entirely can be due to a variety of problems with one or more components of an air conditioner or air conditioning system. Forecasting for system failure rates are very important for maintenance. This paper focused on the reliability of the air conditioning systems. Statistical distributions that were commonly applied in reliability settings: the standard (2 parameter) Weibull and Gamma distributions. After distributions parameters had been estimated, reliability estimations and predictions were used for evaluations. To evaluate good operating condition in a building, the reliability of the air conditioning system that supplies conditioned air to the several The company's departments. This air conditioning system is divided into two, namely the main chilled water system and the ten air handling systems that serves the ten departments. In a chilled-water system the air conditioner cools water down to 40-45 degree F (4-7 degree C). The chilled water is distributed throughout the building in a piping system and connected to air condition cooling units wherever needed. Data analysis has been done with support a computer aided reliability software, this is due to the Weibull and Gamma distributions indicated that the reliability for the systems equal to 86.012% and 77.7% respectively. A comparison between the two important families of distribution functions, namely, the Weibull and Gamma families was studied. It was found that Weibull method performed for decision making.

  16. Trading Hot-Air. The Influence of Permit Allocation Rules, Market Power and the US Withdrawal from the Kyoto Protocol

    International Nuclear Information System (INIS)

    Klepper, G.; Peterson, S.

    2005-01-01

    After the conferences in Bonn and Marrakech, it is likely that international emissions trading will be realized in the near future. Major influences on the permit market are the institutional detail, the participation structure and the treatment of hot-air. Different scenarios not only differ in their implications for the demand and supply of permits and thus the permit price, but also in their allocative effects. In this paper we discuss likely the institutional designs for permit allocation in the hot-air economies and the use of market power and quantify the resulting effects by using the computable general equilibrium model DART. It turns out that the amount of hot-air supplied will be small if hot-air economies cooperate in their decisions. Under welfare maximization, more hot-air is supplied than in the case where governments try to maximize revenues from permit sales

  17. The uranium supply strategy of China

    International Nuclear Information System (INIS)

    Gao, S.

    2014-01-01

    Currently there are 28 units of nuclear power plants (NPPs) under construction in China. Most of these plants will be put into operation sequentially in a couple years. The paper will present the operational and construction status of NPPs in China. As the reactor fleet increases, the requirement for uranium will also substantially increase. Due to declining air quality, as atmospheric pollution spreads rapidly from northern parts to southern parts of China, the option to develop nuclear power has become the highest priority. Uranium demand will be the key to support the expanded nuclear power in the future. Current and future requirements of uranium and the envisaged supply strategy will be discussed. Domestic production is seen as one of the channels to meet the increased requirement. As the uranium price remain low, there will be limited the expansion of domestic production in the short term. The exploration of economic resources is being promoted. Decreasing production costs is mandated in operations due to low uranium prices at present. Development of overseas uranium resources is another channel to supply for the NPPs. Through acquisition of uranium mining projects, advanced uranium projects and exploration projects, China can meet the requirement of NPPs in the long-term. Joint venture partnership is also flexible option for developing uranium resources overseas. Purchasing uranium in the market is the third option. Complementing the supply by domestic production and overseas development, purchase of uranium product in the market is a simple and easy option. Advantages and disadvantages of these three channels and how these can be combined into an integrated strategy of supply and the proprotionate weightage of each channel for the potential future supply of uranium to the NNP fleet will be discussed. (author)

  18. Compressed Air Energy Storage in Denmark

    DEFF Research Database (Denmark)

    Salgi, Georges Garabeth; Lund, Henrik

    2006-01-01

    is analysed with regard to the Danish energy system. In Denmark, wind power supplies 20% of the electricity demand and 50% is produced by combined heat and power (CHP). The operation of CAES requires high electricity price volatility. However, in the Nordic region, large hydro capacities have so far kept......Compressed air energy storage system (CAES) is a technology which can be used for integrating more fluctuating renewable energy sources into the electricity supply system. On a utility scale, CAES has a high feasibility potential compared to other storage technologies. Here, the technology...

  19. Numerical Modelling and Analysis of Hydrostatic Thrust Air Bearings for High Loading Capacities and Low Air Consumption

    Science.gov (United States)

    Yu, Yunluo; Pu, Guang; Jiang, Kyle

    2017-12-01

    The paper presents a numerical simulation study on hydrostatic thrust air bearings to assess the load capacity, compressed air consumptions, and the dynamic response. Finite Difference Method (FDM) and Finite Volume Method (FVM) are combined to solve the non-linear Reynolds equation to find the pressure distribution of the air bearing gas film and the total loading capacity of the bearing. The influence of design parameters on air film gap characteristics, including the air film thickness, supplied pressure, depth of the groove and external load, are investigated based on the proposed FDM model. The simulation results show that the thrust air bearings with a groove have a higher load capacity and air consumption than without a groove, and the load capacity and air consumption both increase with the depth of the groove. Bearings without the groove are better damped than those with the grooves, and the stability of thrust bearing decreases when the groove depth increases. The stability of the thrust bearings is also affected by their loading.

  20. Neglected environmental health impacts of China's supply-side structural reform.

    Science.gov (United States)

    Zhang, Wei; Zhang, Lei; Li, Ying; Tian, Yuling; Li, Xiaoran; Zhang, Xue; Mol, Arthur P J; Sonnenfeld, David A; Liu, Jianguo; Ping, Zeyu; Chen, Long

    2018-03-15

    "Supply-side structural reform" (SSSR) has been the most important ongoing economic reform in China since 2015, but its important environmental health effects have not been properly assessed. The present study addresses that gap by focusing on reduction of overcapacity in the coal, steel, and iron sectors, combined with reduction of emissions of sulfur dioxide (SO 2 ), nitrogen oxide (NO x ), and fine particulate matter (PM 2.5 ), and projecting resultant effects on air quality and public health across cities and regions in China. Modeling results indicate that effects on air quality and public health are visible and distributed unevenly across the country. This assessment provides quantitative evidence supporting projections of the transregional distribution of such effects. Such uneven transregional distribution complicates management of air quality and health risks in China. The results challenge approaches that rely solely on cities to improve air quality. The article concludes with suggestions on how to integrate SSSR measures with cities' air quality improvement attainment planning and management performance evaluation. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. On Production and Green Transportation Coordination in a Sustainable Global Supply Chain

    Directory of Open Access Journals (Sweden)

    Feng Guo

    2017-11-01

    Full Text Available This paper addresses a coordination problem of production and green transportation and the effects of production and transportation coordination on supply chain sustainability in a global supply chain environment with the consideration of important realistic characteristics, including parallel machines, different order processing complexities, fixed delivery departure times, green transportation and multiple transportation modes. We formulate the measurements for carbon emissions of different transportation modes, including air, sea and land transportation. A hybrid genetic algorithm-based optimization approach is developed to handle this problem, in which a hybrid genetic algorithm and heuristic procedures are combined. The effectiveness of the proposed approach is validated by means of various problem instances. We observe that the coordination of production and green transportation has a large effect on the overall supply chain sustainability, which can reduce the total supply chain cost by 9.60% to 21.90%.

  2. Comparative International Air Cargo Solutions: The Pathway to a Resilient, Adaptable, Balanced and Sustainable Secure Global Air Cargo Supply Chain

    Science.gov (United States)

    2013-12-01

    counterfeit merchandise smugglers, and remains the weakest link in the air cargo transportation chain. The TSA and CBP continue to seek administrative...been exploited by narcotics, human and counterfeit merchandise smugglers for centuries, remains the weakest link in the air cargo transportation chain... visual depiction of the European Union 3rd country security processes. 96 Official Journal of the

  3. Design of Solar Heat Sheet for Air Heaters

    Science.gov (United States)

    Priya, S. Shanmuga; Premalatha, M.; Thirunavukkarasu, I.

    2011-12-01

    The technique of harnessing solar energy for drying offers significant potential to dry agricultural products such as food grains, fruits, vegetables and medicinal plants, thereby eliminating many of the problems experienced with open-sun drying and industrial drying, besides saving huge quantities of fossil fuels. A great deal of experimental work over the last few decades has already demonstrated that agricultural products can be satisfactorily dehydrated using solar energy. Various designs of small scale solar dryers have been developed in the recent past, mainly for drying agricultural products. Major problems experienced with solar dryers are their non-reliability as their operation largely depends on local weather conditions. While back-up heaters and hybrid dryers partly solved this issue, difficulties in controlling the drying air temperature and flow rate remains a problem, and affects the quality of the dried product. This study is aimed at eliminating the fluctuations in the quality of hot air supplied by simple solar air heaters used for drying fruits, vegetables and other applications. It is an attempt to analyse the applicability of the combination of an glazed transpired solar collector (tank), thermal storage and a intake fan(suction fan) to achieve a steady supply of air at a different atmospheric temperature and flow rate for drying fruits and vegetables. Development of an efficient, low-cost and reliable air heating system for drying applications is done.

  4. Operability test procedure for 241-U compressed air system and heat pump

    International Nuclear Information System (INIS)

    Freeman, R.D.

    1994-01-01

    The 241-U-701 compressed air system supplies instrument quality compressed air to Tank Farm 241-U. The supply piping to the 241-U Tank Farm is not included in the modification. Modifications to the 241-U-701 compressed air system include installation of a 15 HP Reciprocating Air Compressor, Ingersoll-Rand Model 10T3NLM-E15; an air dryer, Hankinson, Model DH-45; and miscellaneous system equipment and piping (valves, filters, etc.) to meet the design. A newly installed heat pump allows the compressor to operate within an enclosed relatively dust free atmosphere and keeps the compressor room within a standard acceptable temperature range, which makes possible efficient compressor operation, reduces maintenance, and maximizes compressor operating life. This document is an Operability Test Procedure (OTP) which will further verify (in addition to the Acceptance Test Procedure) that the 241-U-701 compressed air system and heat pump operate within their intended design parameters. The activities defined in this OTP will be performed to ensure the performance of the new compressed air system will be adequate, reliable and efficient. Completion of this OTP and sign off of the OTP Acceptance of Test Results is necessary for turnover of the compressed air system from Engineering to Operations

  5. Simplified model-based optimal control of VAV air-conditioning system

    Energy Technology Data Exchange (ETDEWEB)

    Nassif, N.; Kajl, S.; Sabourin, R. [Ecole de Technologie Superieure, Montreal, PQ (Canada). Dept. of Construction Engineering

    2005-07-01

    The improvement of Variable Air Volume (VAV) system performance is one of several attempts being made to minimize the high energy use associated with the operation of heating, ventilation and air conditioning (HVAC) systems. A Simplified Optimization Process (SOP) comprised of controller set point strategies and a simplified VAV model was presented in this paper. The aim of the SOP was to determine supply set points. The advantage of the SOP over previous methods was that it did not require a detailed VAV model and optimization program. In addition, the monitored data for representative local-loop control can be checked on-line, after which controller set points can be updated in order to ensure proper operation by opting for real situations with minimum energy use. The SOP was validated using existing monitoring data and a model of an existing VAV system. Energy use simulations were compared to that of the existing VAV system. At each simulation step, 3 controller set point values were proposed and studied using the VAV model in order to select a value for each point which corresponded to the best performance of the VAV system. Simplified VAV component models were presented. Strategies for controller set points were described, including zone air temperature, duct static pressure set points; chilled water supply set points and supply air temperature set points. Simplified optimization process calculations were presented. Results indicated that the SOP provided significant energy savings when applied to specific AHU systems. In a comparison with a Detailed Optimization Process (DOP), the SOP was capable of determining set points close to those obtained by the DOP. However, it was noted that the controller set points determined by the SOP need a certain amount of time to reach optimal values when outdoor conditions or thermal loads are significantly changed. It was suggested that this disadvantage could be overcome by the use of a dynamic incremental value, which

  6. Cost-benefit analysis of improved air quality in an office building

    DEFF Research Database (Denmark)

    Djukanovic, R.; Wargocki, Pawel; Fanger, Povl Ole

    2002-01-01

    A cost-benefit analysis of measures to improve air quality in an existing air-conditoned office building (11581 m2, 864 employees) was carried out for hot, temperate and cold climates and for two operating modes: Variable Air Volume (VAV) with economizer; and Constant Air Volume (CAV) with heat...... recovery. The annual energy cost and first cost of the HVAC system were calculat4ed using DOE 2.1E for different levels of air quality (10-50% dissatisfied). This was achieved by changing the outdoor air supply rate and the pollution loads. Previous studies have documented a 1.1% increase in office...

  7. Increased office productivity through improved indoor air quality

    DEFF Research Database (Denmark)

    Fanger, Povl Ole

    2002-01-01

    Control of indoor pollution sources and ventilation are both means of improving indoor air quality. Three independent experiments have recently documented that removing a pollution source or increasing the ventilation rate will improve perceived air quality, reduce the intensity of several Sick...... with the air quality was reduced by either measure. The quantitative relationsh8ip was 1.1% change in performance per 10% dissatisfied, in the range 25-70% dissatisifed, or 0.5% change in performance per 1 decipol (dp), in the range 2-13 dp. Significant improvements in performance occurred only when......, future developments in HVCAC technology may include "personalized air ", new ways of improving the quality of supply air (e.g., by filtration), more extensive use of heat recovery from exhaust air and systematic selection of low-polluting building and furnishing materials....

  8. International air cargo operations and gateways : their emerging importance to the state of Texas.

    Science.gov (United States)

    2011-07-01

    Air cargo transport has become particularly important in todays expanding global : economy for the movement of high-value goods such as electronics, computer components, : precision equipment, medical supplies, auto parts, and perishables. Air car...

  9. Research review: Indoor air quality control techniques

    International Nuclear Information System (INIS)

    Fisk, W.J.

    1986-10-01

    Techniques for controlling the concentration of radon, formaldehyde, and combustion products in the indoor air are reviewed. The most effective techniques, which are generally based on limiting or reducing indoor pollutant source strengths, can decrease indoor pollutant concentrations by a factor of 3 to 10. Unless the initial ventilation rate is unusually low, it is difficult to reduce indoor pollutant concentrations more than approximately 50% by increasing the ventilation rate of an entire building. However, the efficiency of indoor pollutant control by ventilation can be enhanced through the use of local exhaust ventilation near concentrated sources of pollutants, by minimizing short circuiting of air from supply to exhaust when pollutant sources are dispersed and, in some situations, by promoting a displacement flow of air and pollutants toward the exhaust. Active air cleaning is also examined briefly. Filtration and electrostatic air cleaning for removal of particles from the indoor air are the most practical and effective currently available techniques of air cleaning. 49 refs., 7 figs

  10. Development and analysis of an economizer control strategy algorithm to promote an opportunity for energy savings in air conditioning installations

    Energy Technology Data Exchange (ETDEWEB)

    Neto, Jose H.M.; Azevedo, Walter L. [Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET), Belo Horizonte, MG (Brazil). Dept. de Engenharia Mecanica]. E-mail: henrique@daem.des.cefetmg.br

    2000-07-01

    This work presents an algorithm control strategy denominated enthalpy economizer. The objective of this algorithm strategy is to determine the adequate fractions of outside and return air flowrates entering a cooling coil based on the analysis of the outside, return and supply air enthalpies, rather than on the analysis of the dry bulb temperatures. The proposed algorithm predicts the actual opening position of the outside and return air dampers in order to provide the lower mixing air enthalpy. First, the psychometrics properties of the outside and return air are calculated from actual measurements of the dry and wet bulb temperatures. Then, three distinct cases are analyzed: the enthalpy of the outside air is lower than the enthalpy of the supply air (free cooling); the enthalpy of the outside air is higher than the enthalpy of the return air; the enthalpy of the outside air is lower than the enthalpy of the return air and higher than the temperature of the supply air. Different outside air conditions were selected in order to represent typical weather data of Brazilians cities, as well as typical return air conditions. It was found that the enthalpy control strategy could promote an opportunity for energy savings mainly during mild nights and wintertime periods as well as during warm afternoons and summertime periods, depending on the outside air relative humidity. The proposed algorithm works well and can be integrated in some commercial automation software to reduce energy consumption and electricity demand. (author)

  11. Contribution of waterborne radon to home air quality

    International Nuclear Information System (INIS)

    Deb, A.K.

    1994-01-01

    Radon-222 is a member of the uranium decay chain and is formed from the decay of radium-226. Radon and its decay products emit alpha particles during the decay process. If radon is inhaled, alpha particles emitted from inhaled radon and its daughters increase the risk of lung cancer. Radon is soluble in water; thus when radon comes in contact with groundwater it dissolves. The radon concentration in groundwater may range from 100 pCi/L to 1,000,000 pCi/L. When water with a high radon level is used in the home, radon is released from the water to the air and thus can increase indoor air radon concentration. Considering the estimated health risk from radon in public water supply systems, EPA has proposed a maximum contaminant level (MCL) of 300 pCi/L for radon in public drinking water supplies. To address the health risks of radon in water and the proposed regulations, the American Water Works Association Research Foundation (AWWARF) initiated a study to determine the contribution of waterborne radon to radon levels in indoor household air

  12. The future of US LNG imports: A look at changing North American supply trends

    International Nuclear Information System (INIS)

    McDonald, R.A.

    1992-01-01

    Historically, the majority of United States gas consumption has been supplied by Gulf Coast and Midcontinent oil and gas fields. Increasingly, producers are discovering smaller, less economic fields as these areas mature. Expectations are for this trend to continue which will cause finding costs to rise. As gas prices rise, large supplies of remote western U.S. gas will become economic, shifting the locus of supply westward. Simultaneously, gas markets are opening up in the eastern United States driven by the demand for new electric generating capacity and Clean Air Act legislation. Natural gas markets will increasingly be supplied by western gas that is more expensive to find, develop and transport. LNG will become more competitive in the U.S. because (1) future gas demand will outpace domestic supply, and (2) a large portion of the incremental domestic supply in the future will be more expensive due to higher finding and transportation costs. Using the supply economics of modified Arps-Roberts find-rate equations, this paper will share our understanding of the location, timing and economic sensitivities of potential supply and markets and the role LNG can play in them

  13. Companded total condensation loxboil air distillation

    International Nuclear Information System (INIS)

    Erickson, D.C.

    1989-01-01

    This patent describes a dual pressure cryogenic distillation process for producing gaseous oxygen from a supply of compressed and cleaned air, comprising: a. cooling a major fraction of the compressed and cleaned air; b. rectifying the major fraction in a high pressure rectifier to liquid nitrogen overhead product and kettle liquid bottom product; c. distilling the kettle liquid in a low pressure column to liquid oxygen bottom product and gaseous nitrogen overhead product; d. working expanding a compensating vapor comprised of at least 77% N/sub 2/ thereby producing refrigeration; and e. further compressing the remaining minor fraction comprising no more than about 30% of the compressed, cleaned warm air in a compressor powered by the expansion

  14. Feedback linearization based control of a variable air volume air conditioning system for cooling applications.

    Science.gov (United States)

    Thosar, Archana; Patra, Amit; Bhattacharyya, Souvik

    2008-07-01

    Design of a nonlinear control system for a Variable Air Volume Air Conditioning (VAVAC) plant through feedback linearization is presented in this article. VAVAC systems attempt to reduce building energy consumption while maintaining the primary role of air conditioning. The temperature of the space is maintained at a constant level by establishing a balance between the cooling load generated in the space and the air supply delivered to meet the load. The dynamic model of a VAVAC plant is derived and formulated as a MIMO bilinear system. Feedback linearization is applied for decoupling and linearization of the nonlinear model. Simulation results for a laboratory scale plant are presented to demonstrate the potential of keeping comfort and maintaining energy optimal performance by this methodology. Results obtained with a conventional PI controller and a feedback linearizing controller are compared and the superiority of the proposed approach is clearly established.

  15. A Study on the Determination of Power Supply Class for HVAC System in KJRR

    International Nuclear Information System (INIS)

    Kim, Hagtae; Kim, Minjin; Suh, Yong-Suk; Kim, Jun-Yeon; Chae, Hee-Taek

    2016-01-01

    The purpose of this paper is to propose an appropriate electrical class, power supply class, and operation logic for the major equipment of the HVAC system such as a Confinement Isolation Damper (CID), Fission Molybdenum Isolation Damper (FID), Air Handling Unit (AHU), Air Cleaning Unit (ACU), and Contaminated Air Purification System (CAPS) in light of their functional requirements and importance. The classification for the overall HVAC system of the KJRR is a safety class NNS, Non-Seismic category, quality class S, and electrical class Non-1E. Exceptionally, the CID and FID are safety class 3, seismic category I, and quality class Q. The electrical class for the major equipment of the HVAC system should be determined considering the operation concept during Loss of Normal Electric Power (LOEP) regardless of the safety class. In this paper, the electrical and power supply class is determined and the operation logic is proposed for the major equipment of the HVAC system for the KJRR such as the CID, FID, CAPS, ACU, and AHU. The electrical class Non-1E is determined to implement a fail closed for the enhancement of safety. The power supply class is based on the functional requirements of each equipment. The CID, FID, CAPS, and ACU are Class III, but the AHU is Class IV by reflecting the importance and electrical load. After the recovery of the power supply, there is a difference in the operation concept for the HVAC system between the reactor building and fission molybdenum production building depending on the operator's residence time. The CID and CAPS are operated manually through procedures for checking the accident status, and the FID and ACU are operated automatically without special procedures

  16. A Study on the Determination of Power Supply Class for HVAC System in KJRR

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hagtae; Kim, Minjin; Suh, Yong-Suk; Kim, Jun-Yeon; Chae, Hee-Taek [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The purpose of this paper is to propose an appropriate electrical class, power supply class, and operation logic for the major equipment of the HVAC system such as a Confinement Isolation Damper (CID), Fission Molybdenum Isolation Damper (FID), Air Handling Unit (AHU), Air Cleaning Unit (ACU), and Contaminated Air Purification System (CAPS) in light of their functional requirements and importance. The classification for the overall HVAC system of the KJRR is a safety class NNS, Non-Seismic category, quality class S, and electrical class Non-1E. Exceptionally, the CID and FID are safety class 3, seismic category I, and quality class Q. The electrical class for the major equipment of the HVAC system should be determined considering the operation concept during Loss of Normal Electric Power (LOEP) regardless of the safety class. In this paper, the electrical and power supply class is determined and the operation logic is proposed for the major equipment of the HVAC system for the KJRR such as the CID, FID, CAPS, ACU, and AHU. The electrical class Non-1E is determined to implement a fail closed for the enhancement of safety. The power supply class is based on the functional requirements of each equipment. The CID, FID, CAPS, and ACU are Class III, but the AHU is Class IV by reflecting the importance and electrical load. After the recovery of the power supply, there is a difference in the operation concept for the HVAC system between the reactor building and fission molybdenum production building depending on the operator's residence time. The CID and CAPS are operated manually through procedures for checking the accident status, and the FID and ACU are operated automatically without special procedures.

  17. The effects of air leaks on solar air heating systems

    Science.gov (United States)

    Elkin, R.; Cash, M.

    1979-01-01

    This paper presents the results of an investigation to determine the effects of leakages in collector and duct work on the system performance of a typical single-family residence solar air heating system. Positive (leakage out) and negative (leakage in) pressure systems were examined. Collector and duct leakage rates were varied from 10 to 30 percent of the system flow rate. Within the range of leakage rates investigated, solar contribution to heated space and domestic hot water loads was found to be reduced up to 30 percent from the no-leak system contribution with duct leakage equally divided between supply and return duct; with supply duct leakage greater than return leakage a reduction of up to 35 percent was noted. The negative pressure system exhibited a reduction in solar contribution somewhat larger than the positive pressure system for the same leakage rates.

  18. An under-aisle air distribution system facilitating humidification of commercial aircraft cabins

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Tengfei; Yin, Shi; Wang, Shugang [School of Civil and Hydraulic Engineering, Dalian University of Technology (DUT), 2 Linggong Road, Dalian 116024 (China)

    2010-04-15

    Air environment in aircraft cabins has long been criticized especially for the dryness of the air within. Low moisture content in cabins is known to be responsible for headache, tiredness and many other non-specific symptoms. In addition, current widely used air distribution systems on airplanes dilute internally generated pollutants by promoting air mixing and thus impose risks of infectious airborne disease transmission. To boost air humidity level while simultaneously restricting air mixing, this investigation uses a validated computational fluid dynamics (CFD) program to design a new under-aisle air distribution system for wide-body aircraft cabins. The new system supplies fully outside, dry air at low momentum through a narrow channel passage along both side cabin walls to middle height of the cabin just beneath the stowage bins, while simultaneously humidified air is supplied through both perforated under aisles. By comparing with the current mixing air distribution system in terms of distribution of relative humidity, CO{sub 2} concentration, velocity, temperature and draught risk, the new system is found being able to improve the relative humidity from the existent 10% to the new level of 20% and lessen the inhaled CO{sub 2} concentration by 30%, without causing moisture condensation on cabin interior and inducing draught risks for passengers. The water consumption rate in air humidification is only around 0.05 kg/h per person, which should be affordable by airliners. (author)

  19. Energy Analysis of Selected Air Distribution System of Heating, Ventilation and Air Conditioning System: A Case Study of a Pharmaceutical Company

    Directory of Open Access Journals (Sweden)

    DILEEP KUMAR

    2017-07-01

    Full Text Available The higher energy consumption causes environmental degradation along with depletion of conventional energy resources. The share of energy consumption in buildings is increasing with urbanization and that ultimately requires effective measures for energy conservation. In buildings, HVAC (Heating Ventilation and Air Conditioning systems require huge amount of energy. This paper estimates the effects of compression of duct insulation of an HVAC system onthe auxiliary power consumption and temperature of supplied air. A mathematical model is developed in EES (Engineering Equation Solver to ascertain these effects. The simulation results show that the cooling loss due to the insulation compression is about 14%. By increasing the insulation thickness from 10-40mm at selected points, the heat gain is estimated to decrease from 4.29-2.46kW. In addition to that effects of compression of thermal insulation on GHG (Greenhouse Gas emission are investigated to reduce from 4.2-2.3kg/ kW. Subsequently, the AC (Auxiliary Consumption and temperature of the supplied air decrease by 5% and 0.4oC, respectively

  20. Device on a diesel motor to supply power to emergency aggregates

    International Nuclear Information System (INIS)

    Koch, C.; Boekemeier, V.; Schilling, R.

    1977-01-01

    The invented arrangement of a diesel motor for the emergency supply of a nuclear power plant ensures that in the case of a fire in the environment of the emergency feeding building, no air with too much flue gas reaches the diesel motor via the suction pipe. The discharge pipe with a nozzle-shaped discharge opening and the suction pipe running above it pass horizontally through a wall of the building. There are vertical walls on both sides of the openings which prevent a sideways flowing of air to the exhaust gas flow in the vicinity of the building. (HGOE) [de

  1. Power supply instrumentation for pulsed dielectric barrier discharges

    International Nuclear Information System (INIS)

    Quiroz Velázquez, V E; López Callejas, R; De la Piedad Beneitez, A; Rodríguez Méndez, B G; Peña Eguiluz, R; Muñoz Castro, A E; Barocio, S R; Mercado Cabrera, A; Valencia Alvarado, R

    2012-01-01

    The design and implementation of a pulsed high voltage supply intended to the production and control of pulsed dielectric barrier discharges are reported. The instrumentation includes three independently built DC sources coupled to Flyback-like converters using three 1:50 high voltage transformers. The system is capable of supplying voltages up to 70 kV at a 100-2000 Hz repetition rate, delivering 1-500 μs wide pulses. The system has been applied to the development of pulsed dielectric barrier discharges in a stainless steel coaxial reactor 30 cm long and with a 2.54 cm diameter. The inner nickel electrode diameter is 0.005 cm and is embedded in alumina. The discharges have been carried out in room pressure air. Discharges have been implemented. The discharge is made is a water environment for purposes of bacterial elimination.

  2. Measurements and prediction of inhaled air quality with personalized ventilation

    DEFF Research Database (Denmark)

    Cermak, Radim; Majer, M.; Melikov, Arsen Krikor

    2002-01-01

    the room air) at flow rates ranging from less than 5 L/s up to 23 L/s. The air quality assessment was based on temperature measurements of the inhaled air and on the portion of the personalized air inhaled. The percentage of dissatisfied with the air quality was predicted. The results suggest......This paper examines the performance of five different air terminal devices for personalized ventilation in relation to the quality of air inhaled by a breathing thermal manikin in a climate chamber. The personalized air was supplied either isothermally or non-isothermally (6 deg.C cooler than...... that regardless of the temperature combinations, personalized ventilation may decrease significantly the number of occupants dissatisfied with the air quality. Under non-isothermal conditions the percentage of dissatisfied may decrease up to 4 times....

  3. How to optimize tourism destination supply: A case in Shanghai from perspective of supplier and demand side perception

    Science.gov (United States)

    Xue, Huaju; Fang, Chengjiang

    2018-02-01

    It is vital to assess the regional tourist supply capability by suppliers and demand groups. The supply side’s evaluation of the regional supply capacity determines the direction of the supply investment in future, the demand side’s evaluation indicates their satisfaction degree of the destination supply and also effects their revisit the tourism destination. Therefore, the assessment of the supply and demand sides is an important reference for the reform of destination supply side, which helps us find the shortage of the destination supply factors and optimize tourism destination supply promptly. This paper through investigating tourism supply and demand groups in Shanghai, used the survey data and constructed tourism supply optimization model, analyzed the current situation of tourism supply factors in Shanghai. Results showed that the environment of Shanghai should be improved first, including improving urban air and water quality, up-grading public sanitation and increasing urban green coverage. Other supply factors improved priority were information and marketing, we should improve the information consultation of scenic spots, increase the intensity of tourism promotion and provide more free travel publicity brochures.

  4. Indoor air quality in mechanically ventilated residential dwellings/low-rise buildings: A review of existing information

    DEFF Research Database (Denmark)

    Aganovic, Amar; Hamon, Mathieu; Kolarik, Jakub

    Mechanical ventilation has become a mandatory requirement in multiple European standards addressing indoor air quality (IAQ) and ventilation in residential dwellings (single family houses and low-rise apartment buildings). This article presents the state of the art study through a review...... of the existing literature, to establish a link between ventilation rate and key indoor air pollutants. Design characteristics of a mechanical ventilation system such as supply/exhaustairflow, system and design of supply and exhaust outlets were considered. The performance of various ventilation solutionswas......-house ventilation rate was reported below 0.5h-1 or 14 l/s·person in bedrooms, the concentrations of the pollutants elevated above minimum threshold limits (CO2>1350 ppm; TVOC >3000 μg/m3) defined by the standard. Insufficient or non-existent supply of air was related to significantly higher pollutant...

  5. Volcanic air pollution hazards in Hawaii

    Science.gov (United States)

    Elias, Tamar; Sutton, A. Jeff

    2017-04-20

    Noxious sulfur dioxide gas and other air pollutants emitted from Kīlauea Volcano on the Island of Hawai‘i react with oxygen, atmospheric moisture, and sunlight to produce volcanic smog (vog) and acid rain. Vog can negatively affect human health and agriculture, and acid rain can contaminate household water supplies by leaching metals from building and plumbing materials in rooftop rainwater-catchment systems. U.S. Geological Survey scientists, along with health professionals and local government officials are working together to better understand volcanic air pollution and to enhance public awareness of this hazard.

  6. The Design of Hot Water Supply System of Solar Energy and Air Source Heat Pump%太阳能+空气源热泵的热水供应系统设计

    Institute of Scientific and Technical Information of China (English)

    卢春萍

    2015-01-01

    太阳能集中热水系统受到天气的影响难以全天候运行,需要设置辅助加热装置。以广州市宾馆热水供应为例,对太阳能空气源热泵的热水系统进行设计,包括空气源热泵热水机组选型计算、太阳能集热管面积计算、储热水箱的确定、集热循环水泵的确定。%Influenced by weather condition,it is difficult to run for hot water supply system of solar en-ergy all the time,and the auxiliary heating device need setting.Taking hot water supply in a hotel of Guangzhou city as an example in this paper,the heat pump system of solar energy and air source was designed,including the calculation of equipment selection of the air source heat pump, the calculation of the collector area,the determination of the heat storage tank,and the determina-tion of the circulating pump of the heat collection.

  7. Compliance with air quality regulations

    International Nuclear Information System (INIS)

    Steen, D.V.; Tackett, D.L.

    1990-01-01

    Due to the probable passage of Clean Air Act Amendments in 1990, electric utilities throughout the United States are faced with numerous choices to comply with the new acid rain regulations, expected in 1991. The choice of a compliance plan is not a simple task. Every compliance option will be costly. At Ohio Edison, deliberations are quite naturally influenced by past compliance with air quality regulations. This paper discusses compliance with air quality regulations in the 1970's, clean coal technologies and advanced scrubbers, and compliance with air quality regulations in 1995 - 2000. The choice of a compliance strategy for many utilities will involve serving customer loads through some combination of scrubbers, clean coal technologies, fuel switching, fuel blending, redispatch of units, and emissions trading. Whatever the final choice, it must be economic while providing sufficient flexibility to accommodate the critical uncertainties of load growth, state regulatory treatment, markets for emission allowances, advancements in control technologies, additional federal requirements for air emissions, equipment outages and fuel supply disruptions.s

  8. A study of industrial hydrogen and syngas supply systems

    Science.gov (United States)

    Amos, W. J.; Solomon, J.; Eliezer, K. F.

    1979-01-01

    The potential and incentives required for supplying hydrogen and syngas feedstocks to the U.S. chemical industry from coal gasification systems were evaluated. Future hydrogen and syngas demand for chemical manufacture was estimated by geographic area and projected economics for hydrogen and syngas manufacture was estimated with geographic area of manufacture and plant size as parameters. Natural gas, oil and coal feedstocks were considered. Problem areas presently affecting the commercial feasibility of coal gasification discussed include the impact of potential process improvements, factors involved in financing coal gasification plants, regulatory barriers affecting coal gasification, coal mining/transportation, air quality regulations, and competitive feedstock pricing barriers. The potential for making coal gasification the least costly H2 and syngas supply option. Options to stimulate coal gasification system development are discussed.

  9. Simulation of gas supply and consumption during heating season; Simulacija opskrbe potrosaca plinom tijekom ogrjevne sezone

    Energy Technology Data Exchange (ETDEWEB)

    Oklopcic, Z [INA-Naftaplin, Zagreb (Croatia)

    1997-12-31

    In this paper stochastic simulation model of gas supply and consumption during heating season is described. The simulation of gas supply is based on constant import and domestic production and varying production of underground storage which depends on current needs and quantity of gas in the storage. The basis for consumption simulation is the stochastic relationship between gas consumption and mean daily air temperature and type of the day, expressed in the form of linear regression model. Mean daily air temperatures, as one of basic causes of daily gas consumption variations, are simulated, on the basis of statistical characteristics and own air temperature measurements, as a first order autoregression model. By using the developed simulation model the statistical characteristics (expectation, standard deviation) of daily gas consumption and the difference between maximum possible daily supply and consumption (delivery safety margin) are derived for all days in the season. The definition of gas delivery safety is given and critical delivery probabilities for all days in the season and different safety margins are determined. Also, statistical characteristics of critical delivery duration depending on gas reserves status for underground storage is predicted. Predicted gas storage delivery rate is compared against predicted requirements, and on the basis of this comparison possible bottlenecks in gas delivery to consumers and course of future actions are indicated. (author). 3 tabs., 10 figs., 6 refs.

  10. Decision-Making for Supply Chain Integration Supply Chain Integration

    CERN Document Server

    Lettice, Fiona; Durowoju, Olatunde

    2012-01-01

    Effective supply chain integration, and the tight co-ordination it creates, is an essential pre-requisite for successful supply chain management.  Decision-Making for Supply Chain Integration is a practical reference on recent research in the area of supply chain integration focusing on distributed decision-making problems. Recent applications of various decision-making tools for integrating supply chains are covered including chapters focusing on: •Supplier selection, pricing strategy and inventory decisions in multi-level supply chains, •RFID-enabled distributed decision-making, •Operational risk issues and time-critical decision-making for sensitive logistics nodes, Modelling end to end processes to improve supply chain integration, and •Integrated systems to improve service delivery and optimize resource use. Decision-Making for Supply Chain Integration provides an insight into the tools and methodologies of this field with support from real-life case studies demonstrating successful application ...

  11. Environmental assessment of passenger transportation should include infrastructure and supply chains

    International Nuclear Information System (INIS)

    Chester, Mikhail V; Horvath, Arpad

    2009-01-01

    To appropriately mitigate environmental impacts from transportation, it is necessary for decision makers to consider the life-cycle energy use and emissions. Most current decision-making relies on analysis at the tailpipe, ignoring vehicle production, infrastructure provision, and fuel production required for support. We present results of a comprehensive life-cycle energy, greenhouse gas emissions, and selected criteria air pollutant emissions inventory for automobiles, buses, trains, and airplanes in the US, including vehicles, infrastructure, fuel production, and supply chains. We find that total life-cycle energy inputs and greenhouse gas emissions contribute an additional 63% for onroad, 155% for rail, and 31% for air systems over vehicle tailpipe operation. Inventorying criteria air pollutants shows that vehicle non-operational components often dominate total emissions. Life-cycle criteria air pollutant emissions are between 1.1 and 800 times larger than vehicle operation. Ranges in passenger occupancy can easily change the relative performance of modes.

  12. Energy policy for integrating the building environmental performance model of an air conditioned building in a subtropical climate

    International Nuclear Information System (INIS)

    Mui, K.W.

    2006-01-01

    For an air conditioned building, the major electricity consumption is by the heating, and air conditioning (HVAC) system. As energy saving strategies may be in conflict with the criteria of indoor air quality and thermal comfort, a concept of the building environmental performance model (BEPM) has been developed to optimize energy consumption in HVAC systems without any deterioration of the indoor air quality and thermal comfort. The BEPM is divided into two main modules: the adaptive comfort temperature (ACT) module and the new demand control ventilation (nDCV) module. This study aims to enhance and prompt the conventional operation of the air side systems by incorporating temperature reset with the adaptive comfort temperature control and the new demand control ventilation system in high rise buildings in Hong Kong. A new example weather year (1991) was established as a reference to compute the energy use of HVAC systems in buildings in order to obtain more representative data for predicting annual energy consumption. A survey of 165 Hong Kong office buildings was conducted and it provided valuable information on the existing HVAC design values in different grades of private commercial buildings in Hong Kong. It was found that the actual measured values of indoor temperature were lower than the design ones. Furthermore, with the new example weather year and the integration of the BEPM into Grade A private office buildings in Hong Kong, the total energy saving of the air conditioning systems was calculated (i.e. a saving of HK$122 million in electrical consumption per year) while the thermal comfort for the occupants was also maintained

  13. Operability Test Report for 241-U Compressed Air System and heat pump

    International Nuclear Information System (INIS)

    Rensink, G.E.

    1995-01-01

    The 241-U-701 compressed air system supplies instrument quality compressed air to Tank Farm 241-U. The system was upgraded. The operability test showed that the system operates within its intended design parameters. System performance was monitored, recorded, and used to identify areas of concern. Exceptions to the OTP and additional items for safe system performance were minimal and have been resolved; the air system is ready for Operation's use

  14. Design and simulation of a hybrid ventilation system with earth-air heat exchanger

    Energy Technology Data Exchange (ETDEWEB)

    Athienitis, A.K.; Zhao, M. [Concordia Univ., Centre for Building Studies, Montreal, PQ (Canada). Dept. of Building, Civil and Environmental Engineering; Roy, M. [Martin Roy and Associes Group Conseil Inc., Montreal, PQ (Canada)

    2005-07-01

    A simulation study was conducted during the design phase of a new circus building in Montreal which includes a hybrid ventilation system through which fresh air is supplied from an earth-air heat exchanger (EAHE). The EAHE has the potential to satisfy the cooling needs of the building and can also be used to preheat fresh air, thereby satisfying one-third or more of the building's heating needs. Another feature of the building is that it uses displacement ventilation by which the air is supplied at low velocities through large diffusers behind the top level seats or under the seats. In this study, computational fluid dynamics (CFD) simulations were carried out to help size the supply and return units of the heating, ventilating and air conditioning (HVAC) system, as well as the exhaust chimney. The primary objective of the CFD simulation was to determine the maximum velocity and temperature in the seated area to ensure thermal comfort. CFD simulation predictions were found to be in good agreement with preliminary measurements taken in the building. In order to monitor the operation of the system over the next year, the underground ducts were equipped with temperature sensors at several depths into the soil. The energy efficiency of the hybrid HVAC system will be assessed and the velocity and temperature distribution in the theatre will be examined under various operating and energy load conditions. 8 refs., 6 figs.

  15. Energy Performance and Optimal Control of Air-conditioned Buildings Integrated with Phase Change Materials

    Science.gov (United States)

    Zhu, Na

    This thesis presents an overview of the previous research work on dynamic characteristics and energy performance of buildings due to the integration of PCMs. The research work on dynamic characteristics and energy performance of buildings using PCMs both with and without air-conditioning is reviewed. Since the particular interest in using PCMs for free cooling and peak load shifting, specific research efforts on both subjects are reviewed separately. A simplified physical dynamic model of building structures integrated with SSPCM (shaped-stabilized phase change material) is developed and validated in this study. The simplified physical model represents the wall by 3 resistances and 2 capacitances and the PCM layer by 4 resistances and 2 capacitances respectively while the key issue is the parameter identification of the model. This thesis also presents the studies on the thermodynamic characteristics of buildings enhanced by PCM and on the investigation of the impacts of PCM on the building cooling load and peak cooling demand at different climates and seasons as well as the optimal operation and control strategies to reduce the energy consumption and energy cost by reducing the air-conditioning energy consumption and peak load. An office building floor with typical variable air volume (VAV) air-conditioning system is used and simulated as the reference building in the comparison study. The envelopes of the studied building are further enhanced by integrating the PCM layers. The building system is tested in two selected cities of typical climates in China including Hong Kong and Beijing. The cold charge and discharge processes, the operation and control strategies of night ventilation and the air temperature set-point reset strategy for minimizing the energy consumption and electricity cost are studied. This thesis presents the simulation test platform, the test results on the cold storage and discharge processes, the air-conditioning energy consumption and demand

  16. Air Flow and Pressure Drop Measurements Across Porous Oxides

    Science.gov (United States)

    Fox, Dennis S.; Cuy, Michael D.; Werner, Roger A.

    2008-01-01

    This report summarizes the results of air flow tests across eight porous, open cell ceramic oxide samples. During ceramic specimen processing, the porosity was formed using the sacrificial template technique, with two different sizes of polystyrene beads used for the template. The samples were initially supplied with thicknesses ranging from 0.14 to 0.20 in. (0.35 to 0.50 cm) and nonuniform backside morphology (some areas dense, some porous). Samples were therefore ground to a thickness of 0.12 to 0.14 in. (0.30 to 0.35 cm) using dry 120 grit SiC paper. Pressure drop versus air flow is reported. Comparisons of samples with thickness variations are made, as are pressure drop estimates. As the density of the ceramic material increases the maximum corrected flow decreases rapidly. Future sample sets should be supplied with samples of similar thickness and having uniform surface morphology. This would allow a more consistent determination of air flow versus processing parameters and the resulting porosity size and distribution.

  17. Air compressor efficiency in a Vietnamese enterprise

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Ming [3E and T International, Suite 1506, Building No. 10, Luo Ma Shi Street, Xuan Wu District, Beijing 100052 (China)

    2009-06-15

    Compressed air systems in a Vietnamese footwear manufacturing enterprise consume about 10% of enterprise's total electric power supply. Energy efficiency of these air compressor systems, either equipped with new and efficient compressors or old and inefficient ones, can only reach between 5% and 10%. In other words, regardless whatever air compressors were installed, energy loss from the compressor systems was over 80%. This study discovered that energy loss was due to non-optimized operations of the air compressor systems and air leakages. The objectives of the paper are to uncover energy saving potential in Vietnamese air compressor systems, demonstrate methodologies used in the auditing and assessment, share auditing and assessment results, and serve a guide on how to analyze energy efficiency in a compressed air system. This paper concludes that energy efficiency investment in air compressor systems in the Vietnamese enterprise could be extremely cost-effective. If the enterprise invests USD 84,000 in the air compressors to improve efficiency performance, the investment capital will be recovered in about six months. The net present value of the investment will be about USD 864,000 at a discount rate of 12%. (author)

  18. Air compressor efficiency in a Vietnamese enterprise

    Energy Technology Data Exchange (ETDEWEB)

    Yang Ming [3E and T International, Suite 1506, Building No. 10, Luo Ma Shi Street, Xuan Wu District, Beijing 100052 (China)], E-mail: ming.yang7@gmail.com

    2009-06-15

    Compressed air systems in a Vietnamese footwear manufacturing enterprise consume about 10% of enterprise's total electric power supply. Energy efficiency of these air compressor systems, either equipped with new and efficient compressors or old and inefficient ones, can only reach between 5% and 10%. In other words, regardless whatever air compressors were installed, energy loss from the compressor systems was over 80%. This study discovered that energy loss was due to non-optimized operations of the air compressor systems and air leakages. The objectives of the paper are to uncover energy saving potential in Vietnamese air compressor systems, demonstrate methodologies used in the auditing and assessment, share auditing and assessment results, and serve a guide on how to analyze energy efficiency in a compressed air system. This paper concludes that energy efficiency investment in air compressor systems in the Vietnamese enterprise could be extremely cost-effective. If the enterprise invests USD 84,000 in the air compressors to improve efficiency performance, the investment capital will be recovered in about six months. The net present value of the investment will be about USD 864,000 at a discount rate of 12%.

  19. Air compressor efficiency in a Vietnamese enterprise

    International Nuclear Information System (INIS)

    Yang Ming

    2009-01-01

    Compressed air systems in a Vietnamese footwear manufacturing enterprise consume about 10% of enterprise's total electric power supply. Energy efficiency of these air compressor systems, either equipped with new and efficient compressors or old and inefficient ones, can only reach between 5% and 10%. In other words, regardless whatever air compressors were installed, energy loss from the compressor systems was over 80%. This study discovered that energy loss was due to non-optimized operations of the air compressor systems and air leakages. The objectives of the paper are to uncover energy saving potential in Vietnamese air compressor systems, demonstrate methodologies used in the auditing and assessment, share auditing and assessment results, and serve a guide on how to analyze energy efficiency in a compressed air system. This paper concludes that energy efficiency investment in air compressor systems in the Vietnamese enterprise could be extremely cost-effective. If the enterprise invests USD 84,000 in the air compressors to improve efficiency performance, the investment capital will be recovered in about six months. The net present value of the investment will be about USD 864,000 at a discount rate of 12%.

  20. Radon mitigation with mechanical supply and exhaust ventilation adjusted by a pressure control unit

    International Nuclear Information System (INIS)

    Kokotti, H.; Keskikuru, T.; Kalliokoski, P.

    1993-01-01

    Effective ventilation and positive or low negative pressure indoors are suggested to low indoor radon levels. The aim of this study is to develop and to test an equipment, which makes it possible to achieve simultaneously effective ventilation and minimum outdoor-pressure difference. The unit includes mechanical supply and exhaust air fans, a exchanger and a pressure control unit in direct digital control (DDC), which adjusts continuously air exchange based on the pressure difference transmitter information. (orig.). (8 refs., 6 figs.)

  1. Port supply chain integration : analyzing biofuel supply chains

    NARCIS (Netherlands)

    Stevens, Leonie C. E.; Vis, Iris F. A.

    2016-01-01

    This paper focuses on port supply chain integration to strengthen operational and business performance. We provide a structured and comprehensive method to enable port supply chain integration and demonstrate its applicability to the biofuel supply chain. We define the value proposition, role,

  2. Bifunctional electrode performance for zinc-air flow cells with pulse charging

    International Nuclear Information System (INIS)

    Pichler, Birgit; Weinberger, Stephan; Reščec, Lucas; Grimmer, Ilena; Gebetsroither, Florian; Bitschnau, Brigitte; Hacker, Viktor

    2017-01-01

    Highlights: •Manufacture of bi-catalyzed bifunctional air electrodes via scalable process. •Direct synthesis of NiCo 2 O 4 on carbon nanofibers or nickel powder support. •450 charge and discharge cycles over 1000 h at 50 mA cm −2 demonstrated. •Pulse charging with 150 mA cm −2 is successfully applied on air electrodes. •Charge and discharge ΔV of <0.8 V at 50 mA cm −2 when supplied with O 2. -- Abstract: Bifunctional air electrodes with tuned composition consisting of two precious metal-free oxide catalysts are manufactured for application in rechargeable zinc-air flow batteries and electrochemically tested via long-term pulse charge and discharge cycling experiments at 50 mA cm −2 (mean). NiCo 2 O 4 spinel, synthesized via direct impregnation on carbon nanofibers or nickel powder and characterized by energy dispersive X-ray spectroscopy and X-ray diffraction experiments, shows high activity toward oxygen evolution reaction with low charge potentials of < 2.0 V vs. Zn/Zn 2+ . La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3 perovskite exhibits bifunctional activity and outperforms the NiCo 2 O 4 spinel in long-term stability tenfold. By combining the catalysts in one bi-catalyzed bifunctional air electrode, stable performances of more than 1000 h and 450 cycles are achieved when supplied with oxygen and over 650 h and 300 cycles when supplied with synthetic air. In addition, the pulse charging method, which is beneficial for compact zinc deposition, is successfully tested on air electrodes during long-term operation. The oxygen evolution potentials during pulse, i.e. at tripled charge current density of 150 mA cm −2 , are only 0.06–0.08 V higher compared to constant charging current densities. Scanning electron microscopy confirms that mechanical degradation caused by bubble formation during oxygen evolution results in slowly decreasing discharge potentials.

  3. Thermodynamic analysis of an innovative liquid desiccant air conditioning system to supply potable water

    International Nuclear Information System (INIS)

    Ahmed, M.A.; Gandhidasan, P.; Zubair, Syed M.; Bahaidarah, Haitham M.

    2017-01-01

    Highlights: • The study objective is to reduce the energy consumption of desiccant AC system. • Heat and mass losses are recovered in the proposed system using a condenser. • The conventional and the proposed systems are compared in terms of COP. • The proposed system performance is better than the conventional system. • The proposed system produces freshwater in addition to space cooling. - Abstract: Liquid desiccant air conditioning systems are cost-effective, environmentally friendly and energy efficient techniques, especially in coastal areas. In the conventional liquid desiccant air conditioning system, the scavenging air is expelled into the atmosphere carrying a considerable amount of energy and water vapor. Thus, there is plenty of room to improve the system performance by recovering these losses. The proposed system consists of a conventional liquid desiccant air conditioning system plus a condenser. The aim of this study is to reduce the energy consumption by recovering the heat from the scavenging air using the condenser while also producing freshwater in addition to space cooling. Lithium chloride (LiCl) is used as the liquid desiccant for this study. The mathematical formulation for simultaneous heat and mass transfer between the condenser and the regenerator was developed to establish a comparison between the performance of the conventional and modified systems. Using the generated model, it is found that the modified system performance is 11.25% better than the conventional system and that it produces 86.4 kg of freshwater per hour as a by-product under the given conditions.

  4. Advanced air distribution for minimizing airborne cross infection in aircraft cabin

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor; Dzhartov, Viktor

    2012-01-01

    was ventilated at 180 L/s. The concentration of Freon mixed with air exhaled by the “infected” manikin was measured. The personalized flow pushed the contaminated exhaled air backwards where it was pulled by the suction and exhausted before mixing with the cabin air. This resulted in substantial decrease...... simulated “infected” polluting passenger and another simulated “exposed” passenger. Personalized ventilation supplied clean air at 10 L/s from front against manikins’ face. Air was sucked at 10 L/s by a suction system of two nozzles positioned on the sides of “infected” manikin’s head. The cabin...... of the tracer gas concentration in the air inhaled by the “exposed” manikin and the exhausted cabin air....

  5. In the wake of liberalisation: long-term developments in the EU air transport market

    NARCIS (Netherlands)

    Burghouwt, G.; de Wit, J.G.

    2015-01-01

    Using a 24-year analysis period (1990-2013), a new perspective is offered on long-term first- and second-order developments following liberalisation of the intra-EU air transport market. The focus of the analysis is on supply-side issues, such as airline output, structure of supply, yields, business

  6. Comparison of deliverable and exhaustible pressurized air flow rates in laboratory gloveboxes

    International Nuclear Information System (INIS)

    Compton, J.A.

    1994-01-01

    Calculations were performed to estimate the maximum credible flow rates of pressurized air into Plutonium Process Support Laboratories gloveboxes. Classical equations for compressible fluids were used to estimate the flow rates. The calculated maxima were compared to another's estimates of glovebox exhaust flow rates and corresponding glovebox internal pressures. No credible pressurized air flow rate will pressurize a glovebox beyond normal operating limits. Unrestricted use of the pressurized air supply is recommended

  7. Small fan assisted air conditioner for thermal comfort and energy saving in Thailand

    International Nuclear Information System (INIS)

    Atthajariyakul, Surat; Lertsatittanakorn, Charoenporn

    2008-01-01

    From the fact that Thai people have a tolerance to high air temperature and are accustomed to high air movement from electric fans in non-air conditioned space, this paper proposes the use of small fan assisted air conditioners for human thermal comfort and energy saving in Thailand. In the study, a total 15 students were tested in a 2.5 x 3.5 x 2.5 m 3 test room equipped with a 12,000 Btu/h split type air conditioner. During the tests, the room air temperature was varied from 25, 26, 27 and 28 deg. C every 1 h. A small fan with 15 cm diameter was placed in front of each subject. In each hour, the small fan was varied to supply a small area with velocity from 0.2, 0.5, 1, 1.5 and 2 m/s. In each condition, the subjects were asked to vote for their thermal sensation. The results showed that the temperature set point could be increased up to 28 deg. C when a small fan was used to supply local air velocity from 0.5 to 2 m/s according to individual preference. This would reduce the electricity consumption of the air conditioning unit. According to the proposed method, this can save energy for office buildings in the commercial sector as high as 1959.51 GWh/year

  8. Solar assisted heat pump on air collectors: A simulation tool

    Energy Technology Data Exchange (ETDEWEB)

    Karagiorgas, Michalis; Galatis, Kostas; Tsagouri, Manolis [Department of Mechanical Engineering Educators, ASPETE, N. Iraklio, GR 14121 (Greece); Tsoutsos, Theocharis [Environmental Engineering Dept., Technical University of Crete, Technical University Campus, GR 73100, Chania (Greece); Botzios-Valaskakis, Aristotelis [Centre for Renewable Energy Sources (CRES), 19th km Marathon Ave., GR 19001, Pikermi (Greece)

    2010-01-15

    The heating system of the bioclimatic building of the Greek National Centre for Renewable Energy Sources (CRES) comprises two heating plants: the first one includes an air source heat pump, Solar Air Collectors (SACs) and a heat distribution system (comprising a fan coil unit network); the second one is, mainly, a geothermal heat pump unit to cover the ground floor thermal needs. The SAC configuration as well as the fraction of the building heating load covered by the heating plant are assessed in two operation modes; the direct (hot air from the collectors is supplied directly to the heated space) and the indirect mode (warm air from the SAC or its mixture with ambient air is not supplied directly to the heated space but indirectly into the evaporator of the air source heat pump). The technique of the indirect mode of heating aims at maximizing the efficiency of the SAC, saving electrical power consumed by the compressor of the heat pump, and therefore, at optimizing the coefficient of performance (COP) of the heat pump due to the increased intake of ambient thermal energy by means of the SAC. Results are given for three research objectives: assessment of the heat pump efficiency whether in direct or indirect heating mode; Assessment of the overall heating plant efficiency on a daily or hourly basis; Assessment of the credibility of the suggested simulation model TSAGAIR by comparing its results with the TRNSYS ones. (author)

  9. [Verification of bacteriological safety of PCM 40 air conditioner].

    Science.gov (United States)

    Dumas, J L; Ducel, G; Rouge, J C

    1991-01-01

    This study assessed the bacteriological safety of the bedside air conditioner PCM 40 (Howorth Airtech), used for prevention of intraoperative hypothermia, by blowing filtered warm air through a special mattress. The 3 microns bacterial filter of the device released 2,968 +/- 5,618 particles of diameter less than 3 microns per m3 of room air, containing 78,798 +/- 37,243 of such particles per m3. The amount of bacteries in the air pulsed from the mattress was 30 +/- 41 cfu/m3 vs 120 cfu/m3 in the ambient air and in the hot air supply tubing it reached 6 +/- 5 cfu/m3 vs 175 +/- 77 cfu/m3. It is concluded that bacteriological data do not contra-indicate the use of this air conditioner in the operating theater. The only limitations for use are the position (prone or lateral position) and type of surgery (neurosurgery).

  10. Emissions from oil and gas operations in the United States and their air quality implications.

    Science.gov (United States)

    Allen, David T

    2016-06-01

    The energy supply infrastructure in the United States has been changing dramatically over the past decade. Increased production of oil and natural gas, particularly from shale resources using horizontal drilling and hydraulic fracturing, made the United States the world's largest producer of oil and natural gas in 2014. This review examines air quality impacts, specifically, changes in greenhouse gas, criteria air pollutant, and air toxics emissions from oil and gas production activities that are a result of these changes in energy supplies and use. National emission inventories indicate that volatile organic compound (VOC) and nitrogen oxide (NOx) emissions from oil and gas supply chains in the United States have been increasing significantly, whereas emission inventories for greenhouse gases have seen slight declines over the past decade. These emission inventories are based on counts of equipment and operational activities (activity factors), multiplied by average emission factors, and therefore are subject to uncertainties in these factors. Although uncertainties associated with activity data and missing emission source types can be significant, multiple recent measurement studies indicate that the greatest uncertainties are associated with emission factors. In many source categories, small groups of devices or sites, referred to as super-emitters, contribute a large fraction of emissions. When super-emitters are accounted for, multiple measurement approaches, at multiple scales, produce similar results for estimated emissions. Challenges moving forward include identifying super-emitters and reducing their emission magnitudes. Work done to date suggests that both equipment malfunction and operational practices can be important. Finally, although most of this review focuses on emissions from energy supply infrastructures, the regional air quality implications of some coupled energy production and use scenarios are examined. These case studies suggest that both

  11. Air quality and passenger comfort in an air-conditioned bus micro-environment.

    Science.gov (United States)

    Zhu, Xiaoxuan; Lei, Li; Wang, Xingshen; Zhang, Yinghui

    2018-04-12

    In this study, passenger comfort and the air pollution status of the micro-environmental conditions in an air-conditioned bus were investigated through questionnaires, field measurements, and a numerical simulation. As a subjective analysis, passengers' perceptions of indoor environmental quality and comfort levels were determined from questionnaires. As an objective analysis, a numerical simulation was conducted using a discrete phase model to determine the diffusion and distribution of pollutants, including particulate matter with a diameter air quality and dissatisfactory thermal comfort conditions in Jinan's air-conditioned bus system. To solve these problems, three scenarios (schemes A, B, C) were designed to alter the ventilation parameters. According to the results of an improved simulation of these scenarios, reducing or adding air outputs would shorten the time taken to reach steady-state conditions and weaken the airflow or lower the temperature in the cabin. The airflow pathway was closely related to the layout of the air conditioning. Scheme B lowered the temperature by 0.4 K and reduced the airflow by 0.01 m/s, while scheme C reduced the volume concentration of PM 10 to 150 μg/m 3 . Changing the air supply angle could further improve the airflow and reduce the concentration of PM 10 . With regard to the perception of airflow and thermal comfort, the scheme with an airflow provided by a 60° nozzle was considered better, and the concentration of PM 10 was reduced to 130 μg/m 3 .

  12. Effect of primary air content on formation of nitrogen oxides during combustion of Ehkibastuz coal

    Energy Technology Data Exchange (ETDEWEB)

    Kotler, V.R.; Imankulov, Eh.R.

    1986-01-01

    Investigations are discussed carried out in a pilot plant at the Kaz. Power Engineering Scientific Research Institute into the effect of the amount of primary air in coal-dust flame on the final concentration of nitrogen oxides in flue gases. The tests were carried out in a 7500 mm high, 1600 mm dia vertical cylindrical combustion chamber having type P-57 burner, and air dispersed fuel plus additional air supplies located at the top. Amounts of coal dust fed by a drum feeder along the air pipe varied from 100-600 kg/h. The required air was supplied by 5000 m/sup 3//h Type TK-700/5 blowers at 0.04 MPa. Ehkibastuz coal samples contained: 1.3% moisture; 48.1% ash; 38.02% carbon; 2.56% hydrogen; 0.73% sulfur; 0.60% nitrogen; heat of combustion was 14.3 MJ/kg. Results obtained indicate that variations in the amount of primary air in swirl flow burners affect formation of fuel nitrogen; there is an optimum volume at which minimum quantities of nitrogen oxides are formed. Either an increase or decrease in the primary air results in a rise in nitrogen oxide concentration. 3 references.

  13. Computational Fluid Dynamics and Room Air Movement

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm

    2004-01-01

    on the mass fraction transport equation. The importance of ?false? or numerical diffusion is also addressed in connection with the simple description of a supply opening. The different aspects of boundary conditions in the indoor environment as e.g. the simulation of Air Terminal Devices and the simulation......Nielsen, P.V. Computational Fluid Dynamics and Room Air Movement. Indoor Air, International Journal of Indoor Environment and Health, Vol. 14, Supplement 7, pp. 134-143, 2004. ABSTRACT Computational Fluid Dynamics (CFD) and new developments of CFD in the indoor environment as well as quality...... considerations are important elements in the study of energy consumption, thermal comfort and indoor air quality in buildings. The paper discusses the quality level of Computational Fluid Dynamics and the involved schemes (first, second and third order schemes) by the use of the Smith and Hutton problem...

  14. 77 FR 59840 - Statutory Amendments Affecting Transportation of Agricultural Commodities and Farm Supplies

    Science.gov (United States)

    2012-10-01

    ... transportation of farm supplies from the local farm retailer to the ultimate consumer within a 100 air-mile... wholesalers located at port or terminal facilities to either local farm retailers or farms. (See Question 33...] commodities.'' The exemption created by the Act applies to two types of transportation. The first type is...

  15. Resetting of Mg isotopes between calcite and dolomite during burial metamorphism: Outlook of Mg isotopes as geothermometer and seawater proxy

    Science.gov (United States)

    Hu, Zhongya; Hu, Wenxuan; Wang, Xiaomin; Lu, Yizhou; Wang, Lichao; Liao, Zhiwei; Li, Weiqiang

    2017-07-01

    Magnesium isotopes are an emerging tool to study the geological processes recorded in carbonates. Calcite, due to its ubiquitous occurrence and the large Mg isotope fractionation associated with the mineral, has attracted great interests in applications of Mg isotope geochemistry. However, the fidelity of Mg isotopes in geological records of carbonate minerals (e.g., calcite and dolomite) against burial metamorphism remains poorly constrained. Here we report our investigation on the Mg isotope systematics of a dolomitized Middle Triassic Geshan carbonate section in eastern China. Magnesium isotope analysis was complemented by analyses of Sr-C-O isotopic compositions, major and trace element concentrations, and petrographic and mineralogical features. Multiple lines of evidence consistently indicated that post-depositional diagenesis of carbonate minerals occurred to the carbonate rocks. Magnesium isotope compositions of the carbonate rocks closely follow a mixing trend between a high δ26Mg dolomite end member and a low δ26Mg calcite end member, irrespective of sample positions in the section and calcite/dolomite ratio in the samples. By fitting the measured Mg isotope data using a two-end member mixing model, an inter-mineral Δ26Mgdolomite-calcite fractionation of 0.72‰ was obtained. Based on the experimentally derived Mg isotope fractionation factors for dolomite and calcite, a temperature of 150-190 °C was calculated to correspond to the 0.72‰ Δ26Mgdolomite-calcite fractionation. Such temperature range matches with the burial-thermal history of the local strata, making a successful case of Mg isotope geothermometry. Our results indicate that both calcite and dolomite had been re-equilibrated during burial metamorphism, and based on isotope mass balance of Mg, the system was buffered by dolomite in the section. Therefore, burial metamorphism may reset Mg isotope signature of calcite, and Mg isotope compositions in calcite should be dealt with caution in

  16. The critical care air transport program.

    Science.gov (United States)

    Beninati, William; Meyer, Michael T; Carter, Todd E

    2008-07-01

    The critical care air transport team program is a component of the U.S. Air Force Aeromedical Evacuation system. A critical care air transport team consists of a critical care physician, critical care nurse, and respiratory therapist along with the supplies and equipment to operate a portable intensive care unit within a cargo aircraft. This capability was developed to support rapidly mobile surgical teams with high capability for damage control resuscitation and limited capacity for postresuscitation care. The critical care air transport team permits rapid evacuation of stabilizing casualties to a higher level of care. The aeromedical environment presents important challenges for the delivery of critical care. All equipment must be tested for safety and effectiveness in this environment before use in flight. The team members must integrate the current standards of care with the limitation imposed by stresses of flight on their patient. The critical care air transport team capability has been used successfully in a range of settings from transport within the United States, to disaster response, to support of casualties in combat.

  17. Coordinated reset stimulation in a large-scale model of the STN-GPe circuit

    Directory of Open Access Journals (Sweden)

    Martin eEbert

    2014-11-01

    Full Text Available Synchronization of populations of neurons is a hallmark of several brain diseases. Coordinated reset (CR stimulation is a model-based stimulation technique which specifically counteracts abnormal synchrony by desynchronization. Electrical CR stimulation, e.g. for the treatment of Parkinson’s disease (PD, is administered via depth electrodes. In order to get a deeper understanding of this technique, we extended the top-down approach of previous studies and constructed a large-scale computational model of the respective brain areas. Furthermore, we took into account the spatial anatomical properties of the simulated brain structures and incor- porated a detailed numerical representation of 2·104 simulated neurons. We simulated the subthalamic nucleus (STN and the globus pallidus externus (GPe. Connections within the STN were governed by spike-timing dependent plasticity (STDP. In this way, we modeled the physiological and pathological activity of the considered brain structures. In particular, we investigated how plasticity could be exploited and how the model could be shifted from strongly synchronized (pathological activity to strongly desynchronized (healthy activity of the neuronal populations via CR stimulation of the STN neurons. Furthermore, we investigated the impact of specific stimulation parameters especially the electrode position on the stimulation outcome. Our model provides a step forward towards a biophysically realistic model of the brain areas relevant to the emergence of pathological neuronal activity in PD. Furthermore, our model constitutes a test bench for the optimization of both stimulation parameters and novel electrode geometries for efficient CR stimulation.

  18. Perceived air quality and sensory pollution loads in six Danish office buildings

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Krupicz, P.; Szczecinski, A.

    2002-01-01

    Perceived air quality and sensory pollution loads were measured in 6 office buildings with mechanical ventilation without recirculation, in each buildings in 6 representative non-smoking medium-sized and small offices with mixing ventilation. An untrained panel of 43 subjects assessed the air...... quality on a normal weekday when the building was occupied, and on a weekend without occupants in the building. On both occasions the ventilation system was in operation as on a normal working day. Outdoor air supply rate, air temperature, relative humidity, concentration of carbon dioxide and ultrafine...

  19. Huge supply/demand increases seen in oxygenate forecasts

    International Nuclear Information System (INIS)

    Rhoades, A.K.

    1992-01-01

    Industry originally projected that oxygenate supply would not be able to meet the demand created by U.S. oxygenated and reformulated gasoline mandates. This paper reports that those projections have been reserved in two recent industry reports - one from Chemical Market Associates Inc. (CMAI) and one from Pace Consultants Inc. Pace's report, by Paulo Nery and Nathan Sims, predicts gasoline and oxygenates demand, and examines the role ethanol may play in changing those values. CMAI's report estimates captive supply and demand of butylenes and oxygenates. Oxygenates are entering the domestic gasoline market this winter as a result of the 1990 U.S. Clean Air Act Amendments. Methyl tertiary butyl ether (MTBE) is the most important oxygenate, although ethanol, ethyl tertiary butyl ether (ETBE), and tertiary amyl methyl ether (TAME) are gathering market strength. Ethanol's strength is derived from President Bush's ruling granting a waiver to reformulated gasoline containing ethanol. This waiver allows ethanol blends to have a vapor pressure 1 psi higher than other types of gasoline

  20. A Study of Fuel Supplies for Emergency Power Generation at Air Logistics Centers.

    Science.gov (United States)

    1980-06-01

    md Grade PositIon Ogan~zatro IA-aT;; till al IN 0u two Pwuaay POrN POVAfT uga $300 -M HAM I BUSINESS REPLY MAIL I _____ FINN7 MAINli MIN. NII n...34nearly all U.S. military installations met their energy need through procurement from off- site commercial supplies [8:12].". This being the case, military

  1. Field Study on Humidification Performance of a Desiccant Air-Conditioning System Combined with a Heat Pump

    Directory of Open Access Journals (Sweden)

    Koichi Kawamoto

    2016-01-01

    Full Text Available A desiccant air-conditioning system was developed as a latent-load-processing air conditioner in a dedicated outdoor air system during the summer. This study investigated the application of this air-conditioning system to humidification during the winter without using make-up water, thereby eliminating the cause of microbial contamination in air-conditioning systems. The experiments were conducted with a system used for summer applications to determine the feasibility of adsorbing vapor from outdoor air and supplying it to an indoor space. The humidification performance, energy efficiency, and operating conditions were examined. Although the conditions were subpar because the experiments were performed with an actual dedicated outdoor air system, the results showed that it is possible to supply air with a minimum humidity ratio of 5.8 g/kg dry air (DA when the humidity ratio of outdoor air ranges from 1.8 to 2.3 g/kg DA. The minimum humidification performance required for a dedicated outdoor air system was achieved by increasing the airflow rate of the moisture-adsorption side to 2–3 times that of the humidification side. In addition, air leaking from the moisture-adsorption side to the humidification side, improving the mechanical structure, such as by the insulation of the moisture-adsorption side, and an efficient operating method were examined for humidification during the winter.

  2. Experimental Setup For Study of Drop Deformation In Air Flow

    Directory of Open Access Journals (Sweden)

    Basalaev Sergey

    2017-01-01

    Full Text Available Experimental study for study of deformation of drops in air flow is considered. Experimental setup includes a module for obtaining the drops, an air flow system and measuring system. Module for formation of drops is in the form of vertically arranged dropper with capillary with the possibility of formation of fixed drops. Air flow supply system comprises an air pump coupled conduit through a regulating valve with a cylindrical pipe, installed coaxially with dropper. The measuring system includes the video camera located with possibility of visualization of drop and the Pitot gage for measurement of flow rate of air located in the output section of branch pipe. This experimental setup allows to provide reliable and informative results of the investigation of deformation of drops in the air flow.

  3. Reduction of radon from household water supplies

    International Nuclear Information System (INIS)

    Shapiro, P.S.; Sorg, T.J.

    1988-01-01

    Groundwater can be a major source of indoor radon in homes that use individual wells or are served by very small community water supply systems. In the United States, several wells have been found to contain more than 37,000,000 Bq.m -3 of radon dissolved in the water. This radon can be released in the indoor air in the course of using water for normal household activities. A measurement of the radon in the drinking water can be made when an indoor radon problem is suspected. While ventilation may reduce indoor radon levels that result from household water usage, the most common control technique presently applied is removing the radon from the water using a granular activated carbon (GAC) treatment system. Aeration methods are also effective and have been proven to be economical for small community water supplies. Some of the issues faced in using GAC are sizing and maintaining the unit and shielding and disposing of the GAC to prevent exposure from gamma radiation. (author)

  4. Coagulation, flocculation, dissolved air flotation and filtration in the removal of Giardia spp. and Cryptosporidium spp. from water supply.

    Science.gov (United States)

    Andreoli, Fernando César; Sabogal-Paz, Lyda Patricia

    2017-11-15

    Removing protozoa from a water supply using coagulation, flocculation, dissolved air flotation (DAF) and filtration on a bench scale was evaluated. Calcium carbonate flocculation with and without immunomagnetic separation (IMS) was chosen to detect Giardia spp. cysts and Cryptosporidium spp. oocysts in the studied samples. The results indicated that DAF removed between 1.31 log and 1.79 log of cysts and between 1.08 log and 1.42 log of oocysts. The performance was lower in filtration, with the removal of 1.07 log-1.44 log for cysts and 0.82 log-0.98 log for oocysts. The coagulation, flocculation, DAF and filtration steps removed more than 2.2 log of cysts and oocysts from the water studied. However, protozoa were detected in the filtered water, even with turbidity values of 0.2 NTU. The recovery of the detection method met the international criteria and was higher when there was no IMS. Including the third acid dissociation in the IMS was critical to improve the performance of the protocol tested. However, there was an increase in the technical and analytical complexity and costs. It was also observed that the efficiency of the treatment was linked to the performance of the selected method of detecting protozoa.

  5. Synthetic optimization of air turbine for dental handpieces.

    Science.gov (United States)

    Shi, Z Y; Dong, T

    2014-01-01

    A synthetic optimization of Pelton air turbine in dental handpieces concerning the power output, compressed air consumption and rotation speed in the mean time is implemented by employing a standard design procedure and variable limitation from practical dentistry. The Pareto optimal solution sets acquired by using the Normalized Normal Constraint method are mainly comprised of two piecewise continuous parts. On the Pareto frontier, the supply air stagnation pressure stalls at the lower boundary of the design space, the rotation speed is a constant value within the recommended range from literature, the blade tip clearance insensitive to while the nozzle radius increases with power output and mass flow rate of compressed air to which the residual geometric dimensions are showing an opposite trend within their respective "pieces" compared to the nozzle radius.

  6. Energy analysis of under-floor air distribution (UFAD) system: An office building case study

    International Nuclear Information System (INIS)

    Alajmi, Ali F.; Abou-Ziyan, Hosny Z.; El-Amer, Wid

    2013-01-01

    Highlights: • The key issue for efficient performance of UFAD system is to ensure the thermal stratification establishment. • The unnecessarily excess air supplied to the room deteriorates the thermal stratification. • Improper UFAD operation increases the fan power and HVAC electric demand. • The proper UFAD system is typically more efficient than the existed UFAD system with energy savings of about 23–37%. • UFAD system shows over the CBAD system saving by about 37–39% during the peak months and 51% during October. - Abstract: This paper presents the results of an experimental and theoretical investigation to evaluate an under-floor air distribution (UFAD) system existed in an office building working on hot climate. Air temperature a distribution and supply air velocity are measured in two measuring stations; each consists of eight temperature sensors which were installed to measure room air temperatures along zone height. The obtained data shows an inefficient operation of the UFAD system which deteriorates the advantages of energy saving that presumed by UFAD system. The building energy simulation program, EnergyPlus, was used to identify the best setting of UFAD system and compare it with the existed UFAD and the conventional ceiling based air distribution (CBAD) system. The simulation results show that setting of room thermostat at 26 °C and supply air temperature at 18 °C provides the best efficient UFAD system. Due to improper operation of the tested UFAD system, its actual consumption is found to be higher than the best simulated UFAD by 23–37% during July to October. Also, the simulation results show that the HVAC demand of UFAD is lower than CBAD by 37–39% during July–September and 51% in October

  7. Proposal for the award of a contract for the design, supply, installation and commissioning of a ventilation and air conditioning system for the ECN3 experimental area and the TCC8 and GHN300 service tunnels and for the dismantling of the existing system

    CERN Document Server

    2014-01-01

    Proposal for the award of a contract for the design, supply, installation and commissioning of a ventilation and air conditioning system for the ECN3 experimental area and the TCC8 and GHN300 service tunnels and for the dismantling of the existing system

  8. Risk Assessment for Water Supply Systems in Iran During Crises Using the RAMCAP Method

    Directory of Open Access Journals (Sweden)

    Jalal Nakhaei

    2017-09-01

    Full Text Available Heavy damages might be inflicted upon national infrastructure due to a variety of disasters caused by natural events or human activities. One example of such vital infrastructure at risk is the water supply system. At the time of crises, the water supply system is expected to continue supplying water to citizens, or the crisis will be augmented. This warrants the potential threats and their effects on the system to be identified and evaluated in an attempt to determine the vulnerable systems and sites toward proper solutions. In this study, the assets and the associated threats of the water supply are identified followed by a vulnerability analysis. The RAMCAP method is then employed to determine values for the risks associated with each of the assets including dams, water storage systems, pumping stations, treatment plants, water wells, and building units. Methods are proposed to reduce these risks before a crisis occurs. In addition, basic threats due to air-missile and Cyber attacks are also considered.

  9. Experimental investigations on performance of liquid desiccant-vapor compression hybrid air conditioner

    International Nuclear Information System (INIS)

    Mohan, B. Shaji; Tiwari, Shaligram; Maiya, M.P.

    2015-01-01

    A coupled desiccant column is integrated with a conventional room air conditioner (AC) to enhance dehumidification of the room air. One desiccant column (absorber) is placed after the evaporator the other (regenerator) after the condenser of the AC unit. Such a novel liquid desiccant vapour compression hybrid air conditioning system has been fabricated and tested in a balanced ambient room type calorimeter for very low flow rates of liquid desiccant (lithium bromide solution). The moisture from the cold supply air is transferred to the hot condenser air by the desiccant flowing in the loop, thereby complimenting the dehumidification of the room air at the evaporator. The supply air is also sensibly heated during the dehumidification process by liquid desiccant in the absorber, which together enables the hybrid system to maintain low humidity in the room. Whereas the liquid desiccant is regenerated by the condenser waste heat, the entire cooling is derived only by the AC unit. The experimental results show that an increase of room temperature reduces both dehumidification of process air and regeneration of liquid desiccant, whereas an increase of room specific humidity enhances both these for the flow rate of the liquid desiccant in the range of 0.2–1.6% of the air flow rate through the absorber. - Highlights: • A liquid desiccant vapor compression hybrid system is fabricated and tested. • The liquid desiccant reduces latent load but equally increases sensible load. • Hybrid system performance is studied for varying room temperature and humidity. • Higher room temperature lowers air dehumidification and desiccant regeneration. • Increase of room specific humidity enhances dehumidification and also regeneration

  10. Carbon Dioxide Detection and Indoor Air Quality Control.

    Science.gov (United States)

    Bonino, Steve

    2016-04-01

    When building ventilation is reduced, energy is saved because it is not necessary to heat or cool as much outside air. Reduced ventilation can result in higher levels of carbon dioxide, which may cause building occupants to experience symptoms. Heating or cooling for ventilation air can be enhanced by a DCV system, which can save energy while providing a comfortable environment. Carbon dioxide concentrations within a building are often used to indicate whether adequate fresh air is being supplied to the building. These DCV systems use carbon dioxide sensors in each space or in the return air and adjust the ventilation based on carbon dioxide concentration; the higher the concentration, the more people occupy the space relative to the ventilation rate. With a carbon dioxide sensor DCV system, the fresh air ventilation rate varies based on the number ofpeople in the space, saving energy while maintaining a safe and comfortable environment.

  11. Absorption heat pump for a potable water supply in a solar house

    Energy Technology Data Exchange (ETDEWEB)

    Elshamarka, S [Military Technical Coll., Cairo (EG)

    1991-01-01

    Solar houses usually have good potential in arid areas. These areas often suffer from not only a shortage of conventional energy sources, but also of potable water supplies. In this study, a solar air-conditioning system including an absorption heat pump, already in production since the early 1980s, is described for potable water production while performing its air-conditioning duty in a solar house. Compiled weather-conditions of the Hurgada area, on the Red Sea coast of Egypt, were employed for the prediction of the system's productivity, if it were installed in such a locality. An evaluation of the system's feasibility has been conducted. (author).

  12. Designing and testing the optimum design of automotive air-to-air thermoelectric air conditioner (TEAC) system

    International Nuclear Information System (INIS)

    Attar, Alaa; Lee, HoSung

    2016-01-01

    Highlights: • The optimum design of automotive thermoelectric AC system is proposed. • It is optimized by combining the thermal isolation and the dimensionless methods. • An experiment is conducted to validate the analytical design. - Abstract: The current project is discussing the optimization of counter flow air-to-air thermoelectric air conditioners (TEAC) system. Previous work showed an analytical model with experimental validation of a unit cell of TEAC system. However, the focus of this work is to simulate the optimum design of a whole TEAC system from given inlet parameters (i.e., hot and cold air mass flow rates and ambient temperatures). The analytical model was built by combining an optimal design method with dimensional analysis, which was recently developed, and the thermal isolation method in order to optimize the thermoelectric parameters (i.e., electrical current supplied and the number of thermocouples or the geometric factor, simultaneously). Moreover, based on the designed model, an experiment was conducted in order to study the accuracy of the analytical model. Even though the analytical model was built based on the thermoelectric ideal equations, it shows a good agreement with the experiment. This agreement was mainly a result of the use of the thermoelectric effective material properties which are obtained from the measured maximum thermoelectric module parameters. Since the experiment validate the analytical model, this model provides uncomplicated method to study the optimum design at given inputs.

  13. Basing Strategies for Air Refueling Forces in Anti-access/Area-Denial Environments

    Science.gov (United States)

    2015-09-01

    likely, increase manpower allocations to provide specialist technician coverage at all locations. Connecting subunits by air or surface lift could re...at disaggregated bases also may be overwhelmed by local challenges ranging from base security breaches and supply shortages to the presence of...supported units offers some opportunity to protect tanker forces. But the requirement to establish supply warehouses , access agreements, and the like

  14. Multi-Criteria Analysis of Alternative Energy Supply Solutions to Public Nearly Zero Energy Buildings

    Directory of Open Access Journals (Sweden)

    Giedrius Šiupšinskas

    2013-12-01

    Full Text Available The article analyzes energy supply alternatives for modernised public nearly zero energy buildings. The paper examines alternative energy production systems such as heat pumps (air-water and ground-water, solar collectors, adsorption cooling, biomass boiler, solar photovoltaic, wind turbines and combinations of these systems. The simulation of the analysed building energy demand for different energy production alternatives has been performed using TRNSYS modelling software. In order to determine an optimal energy supply variant, the estimated results of energy, environmental, and economic evaluation have been converted into non-dimensional variables (3E using multi-criteria analysis.Article in Lithuanian

  15. Effectiveness evaluation of sources of supply and systems filter in production process of breathing air

    Directory of Open Access Journals (Sweden)

    Woźniak Arkadiusz

    2015-12-01

    Full Text Available The determination of how efficiently filtration systems used for the production of breathing air used in hyperbaric environments are operating is significant both from theoretical and practical points of view. The quality of breathing air and the breathing mixes based on air is crucial with regard to divers' safety. Paradoxically, a change in regulations regarding quality requirements for breathing mixes has imposed the necessity to verify both the technical equipment and laboratory procedures used in their production and verification. The following material, which is a continuation of previous publications, presents results of the conducted research along with the evaluation of effectiveness of the filtration systems used by the Polish Navy.

  16. Supply Chain Connectivity: Enhancing Participation in the Global Supply Chain

    OpenAIRE

    Patalinghug, Epictetus E.

    2015-01-01

    Supply chain connectivity is vital for the efficient flow of trade among APEC economies. This paper reviews the literature and supply chain management, describes the barriers to enhancing participation in global supply chain, analyzes the various measures of supply chain performance, and suggests steps for the Philippines to fully reap the benefits of the global value chain.

  17. Air Dispersion Modeling for the INL Application for a Synthetic Minor Sitewide Air Quality Permit to Construct with a Facility Emission Cap Component

    Energy Technology Data Exchange (ETDEWEB)

    Sondrup, Andrus Jeffrey [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-10-01

    The Department of Energy Idaho Operations Office (DOE-ID) is applying for a synthetic minor, Sitewide, air quality permit to construct (PTC) with a facility emission cap (FEC) component from the Idaho Department of Environmental Quality (DEQ) for Idaho National Laboratory (INL) to limit its potential to emit to less than major facility limits for criteria air pollutants (CAPs) and hazardous air pollutants (HAPs) regulated under the Clean Air Act. This document is supplied as an appendix to the application, Idaho National Laboratory Application for a Synthetic Minor Sitewide Air Quality Permit to Construct with a Facility Emissions Cap Component, hereafter referred to as “permit application” (DOE-ID 2015). Air dispersion modeling was performed as part of the permit application process to demonstrate pollutant emissions from the INL will not cause a violation of any ambient air quality standards. This report documents the modeling methodology and results for the air dispersion impact analysis. All CAPs regulated under Section 109 of the Clean Air Act were modeled with the exception of lead (Pb) and ozone, which are not required to be modeled by DEQ. Modeling was not performed for toxic air pollutants (TAPs) as uncontrolled emissions did not exceed screening emission levels for carcinogenic and non-carcinogenic TAPs. Modeling for CAPs was performed with the EPA approved AERMOD dispersion modeling system (Version 14134) (EPA 2004a) and five years (2000-2004) of meteorological data. The meteorological data set was produced with the companion AERMET model (Version 14134) (EPA 2004b) using surface data from the Idaho Falls airport, and upper-air data from Boise International Airport supplied by DEQ. Onsite meteorological data from the Grid 3 Mesonet tower located near the center of the INL (north of INTEC) and supplied by the local National Oceanic and Atmospheric Administration (NOAA) office was used for surface wind directions and wind speeds. Surface data (i

  18. Costic's technical day: thermodynamical heating and air conditioning in accommodations (heat pumps and heating/cooling floors). Air systems and their application in collective installations; Journee technique Costic: chauffage thermodynamique et climatisation dans l'habitat (les pompes a chaleur, les planchers chauffants-rafraichissants). Les systemes a air les applications en collectif

    Energy Technology Data Exchange (ETDEWEB)

    Lenotte, J.J.

    2002-07-01

    Direct expansion air systems are now currently used in individual residential houses. Some of these systems are used also in collective residential buildings where they allow to take into account the individualization of consumptions, as wished by some property developers. Some other centralized air-conditioning systems can be used. They require a distribution water loop for the supply of terminal units of ventilation-convection type. This document presents successively: the direct expansion air systems (direct emission air/air heat pumps, aeraulic distribution air/air heat pumps, production dimensioning, implementation, regulation, systems with variable flow rate of refrigerant); the centralized air/water systems with ventilation-convection systems (production dimensioning, implementation, regulation); the air distribution and diffusion. (J.S.)

  19. The development of air cooled condensation systems

    International Nuclear Information System (INIS)

    Bodas, J.

    1990-01-01

    EGI - Contracting/Engineering has had experience with the development of air cooled condensing systems since the 1950's. There are two accepted types of dry cooling systems,the direct and the indirect ones. Due to the fact that the indirect system has several advantages over the direct one, EGI's purpose was to develop an economic, reliable and efficient type of indirect cooling system, both for industrial and power station applications. Apart from system development, the main components of dry cooling plant have been developed as well. These are: the water-to-air heat exchangers; the direct contact (DC, or jet) condenser; the cooling water circulating pumps and recovery turbines; and the peak cooling/preheating units. As a result of this broad development work which was connected with intensive market activity, EGI has supplied about 50% of the dry cooling plants employed for large power stations all over the world. This means that today the cumulated capacity of power units using Heller type dry cooling systems supplied and contracted by EGI is over 6000 MW

  20. New air cleaning technology in Japan

    International Nuclear Information System (INIS)

    Yoshida, Y.; Kitani, S.; Matsui, H.; Ikezawa, Y.

    1981-01-01

    Application of the new techniques and improvements in air cleaning systems have been made to reduce release of radioactive materials from nuclear facilities based on the ALARA concept. For example, the reduction of release of radioactive gaseous effluents has been made by installation of a charcoal gas hold-up system and a clean steam supply system for a turbine gland seal in a BWR and of a gas decay tank system in a PWR. In connection with the effort for reduction of releases in plants, research and development on air cleaning technology have also been made. Some activities mentioned in the present paper are: removal of particulates, airborne radioiodine, noble gases and tritium; penetration characteristics of submicron DOP aerosol for HEPA filters; radioiodine removal from air exhausts; and operational performance of the incineration plants using ceramic filters

  1. Alignment of global supply networks based on strategic groups of supply chains

    Directory of Open Access Journals (Sweden)

    Nikos G. Moraitakis

    2017-09-01

    Full Text Available Background: From a supply chain perspective, often big differences exist between global raw material suppliers’ approaches to supply their respective local markets. The progressing complexity of large centrally managed global supply networks and their often-unknown upstream ramifications increase the likelihood of undetected bottlenecks and inefficiencies. It is therefore necessary to develop an approach to strategically master the upstream complexity of such networks from a holistic supply chain perspective in order to align regional competitive priorities and supply chain structures. The objective of this research is hence to develop an approach for the supply-chain-based alignment of complex global supply networks. Method: We review existing literature from the fields of supply chain and network management, strategic sourcing, and strategic management. Based on the literature review and theoretical and practical considerations we deduce a conceptual approach to consider upstream supply chain structures in supply network alignment initiatives. Results: On the basis of these considerations and current empirical literature we transfer strategic group theory to the supply network management context. The proposed approach introduces strategic groups of supply chains as a segmentation criterion for complex global supply networks which enables the network-wide alignment of competitive priorities. Conclusion: Supply-chain-based segmentation of global supply network structures can effectively reduce the complexity, firms face when aiming to strategically align their supply chains on a holistic level. The results of this research are applicable for certain types of global supply networks and can be used for network alignment and strategy development. The approach can furthermore generate insights useable for negotiation support with suppliers.

  2. Water supply

    International Nuclear Information System (INIS)

    Peterson, F.L.

    1986-01-01

    Options and methodologies for the development of fresh water supplies on Bikini Atoll are much the same as those practiced in the rest of the Marshall Islands and for that matter, most atolls in the central Pacific Ocean Basin. That is, rainfall distribution on Bikini produces a distinct wet season, lasting from about May through November, with the remaining months being generally dry. As a result, fresh water from surface catchments tends to be plentiful during the wet season? but is usually scarce during the dry months, and alternative sources such as groundwater must be utilized during this time. On Bikini the problems of fresh water supply are somewhat more difficult than for most Marshall Island atolls because rainfall is only about half the Marshall Island's average. Tus water supply is a critical factor limiting the carrying capacity of Bikini Atoll. To address this problem BARC has undertaken a study of the Bikini Atoll water supply. Te primary objectives of this work are to determine: (1) alternatives available for fresh water supply, 2 the amounts, location and quality of available supplies and 3 optimal development methods. The study planned for one's year duration, has been underway only since the summer of 1985 and is thus not yet fully completed. However, work done to date, which is presented in this report of preliminary findings, provides a reasonably accurate picture of Bikini's fresh water supplies and the various options available for their development. The work remaining to be completed will mainly add refinements to the water supply picture presented in the sections to follow

  3. Performance test of a grid-tied PV system to power a split air conditioner system in Surabaya

    Science.gov (United States)

    Tarigan, E.

    2017-11-01

    Air conditioner for cooling air is one of the major needs for those who live in hot climate area such as Indonesia. This work presents the performance test of a grid-tied PV system to power air conditioner under a hot tropical climate in Surabaya, Indonesia. A 800 WP grid-tied photovoltaic (PV) system was used, and its performance was tested to power a 0.5 pk of split air conditioner system. It was found that about 3.5 kWh daily energy was consumed by the tested air conditioner system, and about 80% it could be supplied from the PV system. While the other 20% was supplied by the grid during periods of low solar irradiation, 440 Wh of energy was fed into the grid during operation out of office hours. By using the grid-tied PV system, the energy production by PV system did not need to match the consumption of the air conditioner. However, a larger capacity of PV system would mean that a higher percentage of the load would be covered by PV system.

  4. What Can Healthcare Supply Chains Learn from Consumer-Product Supply Chains?

    OpenAIRE

    Schwarz, Leroy B.

    2008-01-01

    A Framework for Thinking About Supply-Chain Management: “The IDIB Portfolio” (Information, Decision-making, Implementation, Buffer system) Describe Supply-Chains for Consumer Products Before “Wal-Mart” Describe Supply-Chains for Consumer Products After “Wal-Mart” Describe Stylized Supply Chain for Healthcare Products

  5. Final programmatic environmental impact statement for tritium supply and recycling

    International Nuclear Information System (INIS)

    1995-10-01

    Tritium, a radioactive gas used in all of the Nation's nuclear weapons, has a short half-life and must be replaced periodically in order for the weapon to operate as designed. Currently, there is no capability to produce the required amounts of tritium within the Nuclear Weapons Complex. The PEIS for Tritium Supply and Recycling evaluates the alternatives for the siting, construction, and operation of tritium supply and recycling facilities at each of five candidate sites: the Idaho National Engineering Laboratory, the Nevada Test Site, the Oak Ridge Reservation, the Pantex Plant, and the Savannah River Site. Alternatives for new tritium supply and recycling facilities consist of four different tritium supply technologies: Heavy Water Reactor, Modular High Temperature Gas-Cooled Reactor, Advanced Light Water Reactor, and Accelerator Production of Tritium. The PEIS also evaluates the impacts of the DOE purchase of an existing operating or partially completed commercial light water reactor or the DOE purchase of irradiation services contracted from commercial power reactors. Additionally, the PEIS includes an analysis of multipurpose reactors that would produce tritium, dispose of plutonium, and produce electricity. Evaluation of impacts on land resources, site infrastructure, air quality and acoustics, water resources, geology and soils, biotic resources, cultural and paleontological resources, socioeconomics, radiological and hazardous chemical impacts during normal operation and accidents to workers and the public, waste management, and intersite transport are included in the assessment

  6. Anti-kindling induced by two-stage coordinated reset stimulation with weak onset intensity

    Directory of Open Access Journals (Sweden)

    Magteld eZeitler

    2016-05-01

    Full Text Available Abnormal neuronal synchrony plays an important role in a number of brain diseases. To specifically counteract abnormal neuronal synchrony by desynchronization, Coordinated Reset (CR stimulation, a spatiotemporally patterned stimulation technique, was designed with computational means. In neuronal networks with spike timing–dependent plasticity CR stimulation causes a decrease of synaptic weights and finally anti-kindling, i.e. unlearning of abnormally strong synaptic connectivity and abnormal neuronal synchrony. Long-lasting desynchronizing aftereffects of CR stimulation have been verified in pre-clinical and clinical proof of concept studies. In general, for different neuromodulation approaches, both invasive and non-invasive, it is desirable to enable effective stimulation at reduced stimulation intensities, thereby avoiding side effects. For the first time, we here present a two-stage CR stimulation protocol, where two qualitatively different types of CR stimulation are delivered one after another, and the first stage comes at a particularly weak stimulation intensity. Numerical simulations show that a two-stage CR stimulation can induce the same degree of anti-kindling as a single-stage CR stimulation with intermediate stimulation intensity. This stimulation approach might be clinically beneficial in patients suffering from brain diseases characterized by abnormal neuronal synchrony where a first treatment stage should be performed at particularly weak stimulation intensities in order to avoid side effects. This might, e.g., be relevant in the context of acoustic CR stimulation in tinnitus patients with hyperacusis or in the case of electrical deep brain CR stimulation with sub-optimally positioned leads or side effects caused by stimulation of the target itself. We discuss how to apply our method in first in man and proof of concept studies.

  7. The role of supply chain collaboration in supply chain risk mitigation

    OpenAIRE

    Chen, Jie

    2017-01-01

    In the last two decades, supply chain operations have changed drastically. Globalization of the market, shortened product life cycle, global outsourcing and offshoring, and increasing complexity of the supply base has resulted in modern supply chains becoming more vulnerable than ever. There are also more frequent natural or man-made disasters which disrupt the supply chain operations. All these have led to higher exposure of risks of supply chains and the failure to manage the...

  8. Responses of soil respiration and barley growth to modified supply of oxygen in the soil

    Directory of Open Access Journals (Sweden)

    A. SIMOJOKI

    2008-12-01

    Full Text Available Roots of dry-land plants are supplied with oxygen mainly by molecular diffusion from soil air. Roots may suffer from hypoxia if soil aeration is reduced by compaction and wetting. Although the mechanisms involved are well known, more research is needed to relate soil aeration status to plant growth. The effects of reduced oxygen supply on soil respiration and the growth of barley seedlings were studied in pot experiments with fine sand soil, where the soil air composition was varied by flushing the soil with gas streams containing 0%, 2%, 6%, 10% or 20% O2 independently of compactness (bulk density 1.4, 1.6 Mg m-3 and wetness (air space 0-5%, >5%. Plant growth decreased only at 0-2% O2 in the loose moist soil but as early as 20% O2 in the wet soil. Soil compaction impaired plant growth regardless of wetting and aeration. In the loose moist soil cropped with barley, the respiration rate (emission of CO2 did not decrease at 6% O2 but decreased clearly at 0-2% O2. The results compared fairly well with the critical oxygen concentrations calculated by a simple multicylindrical model, in which the water-film thickness around the roots was estimated using soil water retention data.

  9. Design of Supply Chain Networks with Supply Disruptions using Genetic Algorithm

    OpenAIRE

    Taha, Raghda; Abdallah, Khaled; Sadek, Yomma; El-Kharbotly, Amin; Afia, Nahid

    2014-01-01

    The design of supply chain networks subject to disruptions is tackled. A genetic algorithm with the objective of minimizing the design cost and regret cost is developed to achieve a reliable supply chain network. The improvement of supply chain network reliability is measured against the supply chain cost.

  10. Wiring of instrument for measuring pulse count of pseudocoincidences in radiation detectors

    International Nuclear Information System (INIS)

    Hekrdle, J.

    1978-01-01

    A network is described consisting of a flip-flop circuit, a pulse counter, a shift register, a gate and a clock generator. Pulses from an alpha detector are applied to the adjusting input of the control flip-flop whose output is connected to the reset input of the pulse counter and to the control input of the gate for beta pulses delayed by the shift register. The pulse counter is supplied with pulses from the clock generator output. The pulses also energize the shift register. The control flip-flop is reset by the output of the pulse counter overflow and also by the beta pulse passing through the open gate to the output terminal. (H.S.)

  11. EFFECT OF POWER SUPPLY AND DUTY CONTROL IN CRANKCASE FLOW (CRANKCASE PRESSURE PORT OF ECV

    Directory of Open Access Journals (Sweden)

    MD. IQBAL MAHMUD

    2016-06-01

    Full Text Available The electromagnetic control valve (ECV operated by solenoid in the external variable compressor with the swash plate type is the rising phenomenon. ECV controls the air conditioning compressor for automobile on the basis of the input signal of the pulse width modulation (PWM that supplied from the external controller. PWM technique is used to encode the information for transmission; its main use is to allow the control of the power to be supplied to electrical devices, especially to inertial loads. The mechanism changes the swash plate angle inside the compressor by increasing or reducing the pressure of swash plate chamber by use of the functions of different pressure port within the ECV. Increasing and reducing the swash plate angle finally depends on the solenoid force acting on the rate of supply of current. This research paper investigates the effect of power supply and duty control during the crankcase flowing at Pc pressure port of ECV.

  12. Determination of tricresyl phosphate air contamination in aircraft.

    Science.gov (United States)

    Denola, G; Hanhela, P J; Mazurek, W

    2011-08-01

    Monitoring of tricresyl phosphate (TCP) contamination of cockpit air was undertaken in three types of military aircraft [fighter trainer (FT), fighter bomber (FB), and cargo transport (CT) aircraft]. The aircraft had a previous history of pilot complaints about cockpit air contamination suspected to originate from the engine bleed air supply through the entry of aircraft turbine engine oil (ATO) into the engine compressor. Air samples were collected in flight and on the ground during engine runs using sorbent tubes packed with Porapak Q and cellulose filters. A total of 78 air samples were analysed, from 46 different aircraft, and 48 samples were found to be below the limit of detection. Nine incidents of smoke/odour were identified during the study. The concentrations of toxic o-cresyl phosphate isomers were below the level of detection in all samples. The highest total TCP concentration was 51.3 μg m(-3), while most were generally found to be contamination of cabin/cockpit air has been the subject of much concern in aviation, quantitative data are sparse.

  13. Technology Solutions Case Study: Air Leakage and Air Transfer Between Garage and Living Space, Waldorf, Maryland

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-11-01

    In this project, Building Science Corporation worked with production homebuilder K. Hovnanian to evaluate air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multipoint fan pressurization tests and additional zone pressure diagnostic testing measured the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

  14. Energy saving opportunity with variable speed drive in primary air-handling unit

    International Nuclear Information System (INIS)

    Li, J.S.M.

    2007-01-01

    Air conditioners used in the court buildings in Kowloon City, Hong Kong were retrofitted with variable speed drives in the primary air handling unit (PAU) in an effort to reduce energy consumption. The initial effect of this retrofit was investigated along with the feasibility of using a carbon dioxide (CO 2 ) based demand control ventilation to reduce energy consumption while optimizing indoor air quality. The air flow in most air conditioning fans is either constant or controlled by motorized inlet guide vanes. Although this controls the flow and may reduce the load on the fan, this constriction adds an energy loss, resulting in inefficient operation. Variable speed drives should be used on the PAU in order to maintain system efficiency. As the speed of the fans are reduced, the flow will decrease proportionally, while the power required by the fan will reduce the cube of the speed. Therefore, if the fresh air supply can be controlled by reducing the speed of the fan motor, then flow control would be more efficient. The energy saving associated with variable fresh air supply flow rate was evaluated along with the cost to building owners. This paper presented the results of the potential energy and cost savings associated with this retrofit, and included implementation cost and pay back period. It was estimated that about 20 per cent of power consumption and electricity costs can be saved per year, with a simple payback period of 2 years. 7 refs., 3 tabs., 3 figs

  15. Condensation of atmospheric moisture from tropical maritime air masses as a freshwater resource.

    Science.gov (United States)

    Gerard, R D; Worzel, J L

    1967-09-15

    A method is proposed whereby potable water may be obtained by condensing moisture from the atmosphere in suitable seashore or island areas. Deep, cold, offshore seawater is used as a source of cold and is pumped to condensers set up on shore to intercept the flow of highly humid, tropical, maritime air masses. This air, when cooled, condenses moisture, which is conducted away and stored for use as a water supply. Windmill-driven generators would supply low-cost power for the operation. Side benefits are derived by using the nutritious deep water to support aquiculture in nearby lagoons or to enhance the productivity of the outfall area. Additional benefits are derived from the condenser as an air-conditioning device for nearby residents. The islands of the Caribbean are used as an example of a location in the trade-winds belt where nearly optimum conditions for the operation of this system can be found.

  16. Contract Coordination in Dual Sourcing Supply Chain under Supply Disruption Risk

    Directory of Open Access Journals (Sweden)

    Tong Shu

    2015-01-01

    Full Text Available This paper explores a coordination model for a three-echelon supply chain including two different manufacturers, one distributer and one retailer via the combined option and back contracts. And one manufacturer provides the high wholesale price with low supply disruption risk and the other is completely the opposite. This differs from the previous supply chain coordination model. Firstly, supply disruption is added to the three-echelon supply chain. Secondly, considering the coordination of the supply chain, we deploy the combined option and back contracts which are seldom used in the previous study. Furthermore, it is interesting that supply disruption risk and buyback factor do not affect the distributor’s order quantity from the manufacturer who has low product price and unreliable operating ability, while the order quantity increases with the rise of option premium and option strike price. The distributor’s order quantity from the manufacturer, which has high product price and reliable operating ability, increases with the rise of supply disruption risk but decreases when the buyback factor, option premium, and option strike price decrease.

  17. Improved inhaled air quality at reduced ventilation rate by control of airflow interaction at the breathing zone with lobed jets

    DEFF Research Database (Denmark)

    Bolashikov, Zhecho Dimitrov; Melikov, Arsen Krikor; Spilak, Michal

    2014-01-01

    Inhaled air quality at a reduced supply of clean air was studied by controlling the airflow interaction at the breathing zone of a person using lobed jets as part of personalized ventilation (PV). Experiments were performed in a full-scale test room at 23°C (73.4°F) with a breathing thermal manikin...... seated at a workstation, with realistic free-convection flow around the body and a normal breathing cycle. The air in the room was mixed with tracer gas R134a. Clean air was supplied isothermally from three nozzles with circular, four-leafed clover, and six-edged star openings of 0.025 m (0.08 ft...... over the interaction between the inserted jets and the free convection flow was efficient. Over 80% clean PV air was measured in inhalation. The worst performing nozzle was the four-leafed clover: its best performance yielded 23% clean air inhalation, at the shortest distance and the highest velocity...

  18. Impact Analysis of Air Pollutant Emission Policies on Thermal Coal Supply Chain Enterprises in China

    OpenAIRE

    Xiaopeng Guo; Xiaodan Guo; Jiahai Yuan

    2014-01-01

    Spurred by the increasingly serious air pollution problem, the Chinese government has launched a series of policies to put forward specific measures of power structure adjustment and the control objectives of air pollution and coal consumption. Other policies pointed out that the coal resources regional blockades will be broken by improving transportation networks and constructing new logistics nodes. Thermal power takes the largest part of China’s total installed power generation capacity, s...

  19. Perspective: Some Causal and Priority Language about Food Energy Supply as the Sufficient Cause of the Obesity Pandemic is Premature or Incorrect

    Science.gov (United States)

    2016-08-09

    Obesity incidence in military members showed a similar association . The causal effect and relative importance of national food energy supply are...the previously described global ecological data, we seek to evaluate whether nationwide food supply is associated with obesity . Additionally, because...considering food energy availability as a continuous variable, the associations with new onset obesity diagnoses within the Air Force (hazard ratio [HR

  20. 76 FR 79560 - Airworthiness Directives; Airbus Airplanes

    Science.gov (United States)

    2011-12-22

    ... off, a transient loss of elevator control associated with a temporary incorrect flight control law... airplane flight manual. We are proposing this AD to prevent movement of the elevators to zero position... reset does not occur thanks to the introduction of second electrical power supply to FCPC3 from 1PP bus...

  1. Effect of Air Stability on the Dispersal of Exhaled Contaminant in Rooms

    DEFF Research Database (Denmark)

    Xu, Chunwen; Gong, Guangcai; Nielsen, Peter V.

    2013-01-01

    the manikin, indicating that the person who exhales the contaminant may not be polluted by himself as the protective effect of the thermal boundary layer around the body, especially in stable condition with two concentration zones and clean air drawn from the inlets. However, other persons facing......Experiments are conducted in a full-scale chamber equipped with whole floor and whole ceiling supply or exhaust to form approximately zero and larger temperature gradients corresponding to unstable and stable air conditions. It can be observed that the air with smoke exhaled from a life...

  2. Advanced air distribution: Improving health and comfort while reducing energy use

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor

    2015-01-01

    -quality indoor environments at the same time as low-energy consumption. Advanced air distribution, designed to supply clean air where, when, and as much as needed, makes it possible to efficiently achieve thermal comfort, control exposure to contaminants, provide high-quality air for breathing and minimizing......Indoor environment affects the health, comfort, and performance of building occupants. The energy used for heating, cooling, ventilating, and air conditioning of buildings is substantial. Ventilation based on total volume air distribution in spaces is not always an efficient way to provide high...... the risk of airborne cross-infection while reducing energy use. This study justifies the need for improving the present air distribution design in occupied spaces, and in general the need for a paradigm shift from the design of collective environments to the design of individually controlled environments...

  3. Gas engine driven freon-free heat supply system complying with multiple fuels (eco-energy city project)

    Energy Technology Data Exchange (ETDEWEB)

    Yagyu, Sumio; Maekawa, Koich; Sugawara, Koich; Hayashida, Masaru; Fujishima, Ichiro; Fukuyama, Yuji; Morikawa, Tomoyuki; Yamato, Tadao; Obata, Norio [Advanced Technology Lab., Kubota Corp., Amagasaki, Hyogo (Japan)

    1999-07-01

    This paper describes recent results at Kubota to develop a gas engine driven freon-free heat supply system. Utilizing a gas mixture which consists of CO and H{sub 2} supplied from a broad area energy utilization network, the system produces four heat sources (263 K, 280 K, 318 K, and 353 K) for air-conditioning, hot water supply, and refrigeration in a single system. It also conforms to fuel systems that utilize methane and hydrogen. This multi-functional heat supply system is composed of an efficient gas engine (methanol gas engine) and a freon-free heat pump (heat-assisted Stirling heat pump). The heat-assisted Stirling heat pump is mainly driven by engine shaft power and is partially assisted by thermal power provided by engine exhaust heat. By proportioning the two energy sources to match the characteristics of the driving engine, the heat pump is supplied with the maximum share of the original energy fueling the engine. Developing the system will establish freon-free thermal utilization system technology that satisfies both wide heat demands and various fuel systems. (orig.)

  4. Air pressure distribution and radon entry processes in east Tennessee schools

    International Nuclear Information System (INIS)

    Sinclair, L.D.; Dudney, C.S.; Wilson, D.L.; Saultz, R.J.

    1990-01-01

    Many building characteristics have been found to influence radon entry, including building size and configuration, substructure, location of utility supply lines, and design and operation of the heating, ventilation, and air conditioning (HVAC) system. One of the most significant factors is room depressurization resulting from the HVAC system exhausting more than it supplies. This paper represents a preliminary assessment of HVAC characteristics and how they may relate to radon entry. During the summer of 1989, a limited survey was made of air pressure and radon levels in four schools in eastern Tennessee. Short-term samples of radon and pressure were made in all rooms in contact with the soil using alpha scintillation cells and an electronic microanometer, respectively. The pressure difference and radon concentration changes induced by operation of the building ventilation system varied among sites within individual schools

  5. Supply Chain Management og Supply Chain costing

    DEFF Research Database (Denmark)

    Nielsen, Steen; Mortensen, Ole

    2002-01-01

    Formålet med denne artikel er at belyse de muligheder som ligger i at integrere virksomhedens økonomiske styring med begrebet Supply Chain Management (SCM). Dette søges belyst ved først at beskrive den teoretiske ramme, hvori SCM indgår. Herefter analyseres begrebet Supply Chain Costing (SCC) som...... Århus. Et resultat er, at via begrebet Supply Chain Costing skabes der mulighed for at måle logistikkædens aktiviteter i kr./øre. Anvendelsen af denne information har også strategisk betydning for at kunne vælge kunde og leverandør. Ved hjælp af integrationen skabes der også helt nye mulighed...

  6. Standardization of iridium-192 coiled source in terms of air kerma output

    Energy Technology Data Exchange (ETDEWEB)

    Shanta, A; Unnikrishnan, K; Tripathi, U B; Kannan, A; Iyer, P S [Bhabha Atomic Research Centre, Bombay (India)

    1996-08-01

    ICRU (1985) recommended that the output of gamma ray brachytherapy sources should be specified in terms of reference air kerma rate, defined as the kerma rate to air in air at a reference distance of 1 meter, perpendicular to the long axis of the source, corrected for air attenuation and scattering. As these measurements are difficult to carry out in the routine clinical use, it is the common practice to calibrate the re-entrant ionization chamber with respect to open air measurements and use the re-entrant chamber for routine measurements. This paper reports on the measurements carried out to correlate the nominal activity and air kerma rate of {sup 192}Ir wire sources supplied by the Board of Radiation and Isotope Technology, Department of Atomic Energy. (author). 3 refs, 1 tab.

  7. Standardization of iridium-192 coiled source in terms of air kerma output

    International Nuclear Information System (INIS)

    Shanta, A.; Unnikrishnan, K.; Tripathi, U.B.; Kannan, A.; Iyer, P.S.

    1996-01-01

    ICRU (1985) recommended that the output of gamma ray brachytherapy sources should be specified in terms of reference air kerma rate, defined as the kerma rate to air in air at a reference distance of 1 meter, perpendicular to the long axis of the source, corrected for air attenuation and scattering. As these measurements are difficult to carry out in the routine clinical use, it is the common practice to calibrate the re-entrant ionization chamber with respect to open air measurements and use the re-entrant chamber for routine measurements. This paper reports on the measurements carried out to correlate the nominal activity and air kerma rate of 192 Ir wire sources supplied by the Board of Radiation and Isotope Technology, Department of Atomic Energy. (author). 3 refs, 1 tab

  8. Development of high-power inverter supply for current drive of FRC plasma

    International Nuclear Information System (INIS)

    Kitano, Katsuhisa; Higashikozono, Takamitsu; Okada, Shigefumi; Goto, Seiichi

    2003-01-01

    High-Power RF supply is developed for the current drive of FRC (Field Reversed Configuration) plasma. The rotating magnetic field is produced by the four antennas set in the parallel direction to the geometrical axis of the FRC and faced each other. The sinusoidal currents with shifted phases by 90 degree each other should be supplied to the antennas. The two power supplies are necessary if a pair of the antennas faced oppositely are connected. Considering the plasma parameters, the rotating field of 50-100kHz and 50G at the center axis is expected to be required. We develop the adequate RF power supply for the purpose. The power supply consists of the inverter circuit, the step-up transformer and the LC tank ciruit. For the switching device of the inverter circuit, the IGBT (Insulated Gate Bipolar Transistor) is adopted. The inverter circuit is full bridge type. To operate it at high voltages, its arm consists of the 3 IGBTs arranged series. The output of the inverter is connected to the tank circuit by way of the step-up transformer with air core. The tank circuit is the parallel circuit of the antenna and the capacitor. By the adjustment of the frequency of the inverter output to the resonance frequency of the tank circuit, the large sinusoidal waveform current is obtained. The developed power supply can produce the current of 5kA at 10kV to the dummy antenna with almost the same inductance of the antenna. (author)

  9. Brachytherapy source calibration, reviews, and consistency of 192Ir high-dose rate afterloading sources supplied over the period of 10 years: a retrospective analysis

    International Nuclear Information System (INIS)

    Nagappan, Balasubramanian; Kumar, Yogesh; Patel, Narayan P.; Dhull, Anil Kumar; Kaushal, Vivek

    2015-01-01

    Measurement and verification of strength of monomodal high-dose rate (mHDR) 192 Ir source supplied by the vendor is a major part of quality assurance program. Reference air kerma rate (RAKR) or air kerma strength (AKS) is the recommended quantity to specify the strength of gamma emitting brachytherapy sources. Physicist in our institution performed the source calibration as soon as each 192 Ir new source was loaded on the mHDR afterloading machine. The AKS accurately measured using a physikalisch technische werkstatten (PTW) re-entrant chamber-electrometer system in a scatter-free geometry was used to compute the air kerma rate (AKR) at one-meter distance in the air. To ensure accurate dose delivery to brachytherapy patients, measured AKS or RAKR should be entered correctly in both HDR treatment console station (TCS) as well as treatment planning system (TPS) associated with it. The clinical outcome mainly depends not only on the accuracy of the source strength measurement in the hospital but also on the correct source strength entered into both TCS and TPS software. A retrospective study on 22 mHDR V2 sources supplied by the vendor for the period of 10 years was taken up to access the accuracy of source strength supplied to the Radiotherapy department. The results are analyzed and reported. The accuracy in measured RAKR of all 22 sources supplied by vendor was well within the tolerance limits set by the national regulatory body and international recommendations. The deviations observed between measured RAKR versus manufacturer's quoted RAKR were in the range from -1.71% to +1.15%. In conclusion, the measured RAKR have good agreement with vendor quoted RAKR values. (author)

  10. The indigenous Sea Gypsy divers of Thailand's west coast: measurement of carbon monoxide in the breathing air.

    Science.gov (United States)

    Gold, D; Geater, A; Aiyarak, S; Juengpraert, W

    1999-07-01

    Approximately 400 indigenous divers live and work on Thailand's west coast. They dive with surface supplied air from primitive compressor units mounted on open boats which measure from seven to 11 meters in length. It was suspected that carbon monoxide was present in the breathing air of at least the gasoline-driven compressor units. To determine the presence of carbon monoxide gas in the breathing air, compressed air from the compressor was pumped through the diver air supply hose through a plenum (monitoring) chamber established on the boat. After a compressor warm-up of 15 minutes, the diving air was measured with the boat at eight different bearings to the wind, each 45 degrees apart at intervals of five minutes. Three of the four gasoline-driven compressor units tested showed presence of carbon monoxide in the breathing air. One diesel-driven unit showed a very low concentration of carbon monoxide (3-4 ppm) and six diesel-driven units showed no detectable carbon monoxide. Although not tested, diesel exhaust emissions could also enter the breathing air by the same route. A locally made modification to the compressor air intake was designed and successfully tested on one gasoline-driven compressor unit. An information sheet on the hazards of carbon monoxide as well as on the modification has been developed for distribution among the villages.

  11. Validation of low-cost ozone measurement instruments suitable for use in an air-quality monitoring network

    International Nuclear Information System (INIS)

    Williams, David E; Henshaw, Geoff S; Bart, Mark; Laing, Greer; Wagner, John; Naisbitt, Simon; Salmond, Jennifer A

    2013-01-01

    This paper presents a novel low-cost instrument that uses a sensor based on conductivity changes of heated tungstic oxide, which is capable of accurately measuring ambient concentrations of ozone. A combination of temperature steps and air flow-rate steps is used to continually reset and re-zero the sensor. A two-stage calibration procedure is presented, in which a nonlinear transformation converts sensor resistance to a signal linear in ozone concentration, then a linear correlation is used to align the calibration with a reference instrument. The required calibration functions specific for the sensor, and control system for air flow rate and sensor temperature, are housed with the sensor in a compact, simple-to-exchange assembly. The instrument can be operated on solar power and uses cell phone technology to enable monitoring in remote locations. Data from field trials are presented here to demonstrate that both the accuracy and the stability of the instrument over periods of months are within a few parts-per-billion by volume. We show that common failure modes can be detected through measurement of signals available from the instrument. The combination of long-term stability, self-diagnosis, and simple, inexpensive repair means that the cost of operation and calibration of the instruments is significantly reduced in comparison with traditional reference instrumentation. These instruments enable the economical construction and operation of ozone monitoring networks of accuracy, time resolution and spatial density sufficient to resolve the local gradients that are characteristic of urban air pollution. (paper)

  12. Air Force Operational Medicine: Using the Estimating Supplies Program to Develop Materiel Solutions for the Operational Clinical Requirements for the U.S. Air Force Otolaryngology Team (FFENT)

    Science.gov (United States)

    2007-10-10

    mapped to supplies required to complete those tasks, linking each supply with a clinical requirement. ESP was used to develop Marine Corps medical...description of ESP’s background, capabilities, uses, frequently asked questions, and a download link is available at http://www.nhrc.navy.mil...MIRROR MOUTH EXAM PLANE GLASS FRONT REFLEC 6520011253245 PROP MOUTH DEN RUBBER M PEDO 30MM OPENING A-31 6520011253246 PROP MOUTH DENTAL RUBBER ADULT

  13. The Use of Supply Chains and Supply Chain Management in the ...

    African Journals Online (AJOL)

    Dr Peter Schmitz

    supply chain management to guide the production of maps. Supply chain management can ... Distribution and logistics. Product flow. Information flow and Money. The Firm. Data from supplier(s) ..... In Global Supply Chains: Developing Skills ...

  14. CONVERTER SOLAR RADIATION INTO ELECTRICITY TO SUPPLY THE AUTOMOTIVE SEMICONDUCTOR THERMOELECTRIC AIR CONDITIONING

    Directory of Open Access Journals (Sweden)

    T. A. Ismailov

    2015-01-01

    Full Text Available The article considers the possibility to increase the efficiency of converters of solar radiation into electricity by combining constructive photoelectric effect, See-beck thermoeffect and semiconductor solar cells, which will create integrated device to provide power semiconductor thermoelectric automobile air conditioner. 

  15. Moisture supply in Danish single-family houses – the influence of occupant behaviour and type of room

    DEFF Research Database (Denmark)

    Møller, Eva B.; Hansen, Ernst Jan de Place

    2017-01-01

    According to ISO 13788, the internal moisture supply in dwellings can be described by humidity classes defined by outdoor temperature, occupancy and ventilation. Hygrothermal measurements in indoor air in 500 Danish single-family houses were made to investigate if this corresponds with reality....... The study focuses on the dependency of number and age of occupants, occupants’ time spent in the house, square meters living space, ventilation habits and type of room. Moisture supply depends on the type of room; bathroom, basement and living room have the highest values. None of the other parameters seems...

  16. Energy supply. Energieversorgung

    Energy Technology Data Exchange (ETDEWEB)

    Eickhof, N.

    1983-01-01

    This anthology presents nine papers dealing with the following subjects: 1) international and national aspects of energy supply, 2) regional and local energy supply concepts, and 3) issues of district-heat supply. Each of the nine papers was entered separately.

  17. Measurement of oxygen transfer from air into organic solvents

    DEFF Research Database (Denmark)

    Ramesh, Hemalata; Mayr, Torsten; Hobisch, Mathias

    2016-01-01

    biological reactions require the supply of oxygen, most normally from air. However, reliable on-line measurements of oxygen concentration in organic solvents (and hence oxygen transfer rates from air to the solvent) has to date proven impossible due limitations in the current analytical methods. Results...... applications). Subsequently, we measured the oxygen transfer rates from air into these organic solvents. Conclusion The measurement of oxygen transfer rates from air into organic solvents using the dynamic method was established using the solvent resistant optical sensor. The feasibility of online oxygen...... For the first time, we demonstrate on-line oxygen measurements in non-aqueous media using a novel optical sensor. The sensor was used to measure oxygen concentration in various organic solvents including toluene, THF, isooctane, DMF, heptane and hexane (which have all been shown suitable for several biological...

  18. Air Distribution in a Room with Ceiling-Mounted Diffusers

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Heby, Thomas; Moeller-Jensen, Bertil

    2006-01-01

    . The characteristics of the air distribution systems are addressed by analysing the acceptable conditions for the supply flow rate and the temperature difference for the different systems. The paper shows that an air distribution system with ceiling-mounted air terminal units is able to generate comfortable velocity...... with swirling flow generates a flow pattern in the room which is rather uninfluenced by the thermal load. The flow is highly mixed above the occupied zone and the air movement penetrates the occupied zone close to the walls. All systems are tested in the same room with the same heat load consisting of two...... manikins, each sitting at a desk, two pc's and two desk lamps producing a total heat load of 480 W. The design of the air distribution system is in all five cases based on flow elements from the diffuser, a maximum velocity assumption and a critical vertical temperature gradient in the room...

  19. Architectures for Green-Field Supply Chain Integration: Supply Chain Integration Design

    OpenAIRE

    Radanliev, Petar

    2015-01-01

    This paper applied case study research to design architectures for green-field supply chain integration. The integration design is based on a case study of a supply chain integration of 5 companies, operating in different, but supply chain complimenting industry sectors. The case study research is applied to design and validate the architectures in a real world scenario. The supply\\ud chain integration architectures enable the conversion of individual into integrated strategies. The architect...

  20. Pengukuran Kinerja Supply Chain Dengan Pendekatan Supply Chain Operation References (SCOR)

    OpenAIRE

    Rizki Wahyuniardi; Moh. Syarwani; Ryan Anggani

    2017-01-01

    PT. Brodo Ganesha Indonesia is a national company engaged in manufacturing with the production of leather shoes. The company has many stakeholders and it is difficult to manage its supply chain, thereby affecting the effectiveness and efficiency of the company's supply chains. The research was conducted to measure the performance of supply chain by using Supply Chain Operation References (SCOR) approach. The initial hierarchy model of performance measurement is tailored to the company's condi...

  1. Ground-Based Midcourse Defense (GMD) Initial Defensive Operations Capability (IDOC) at Vandenberg Air Force Base Environmental Assessment

    Science.gov (United States)

    2003-08-28

    Zielinski , EDAW, Inc., concerning utilities supply and demand for Vandenberg Air Force Base, 1 August. Rush, P., 2002. Personal communication between...Pernell W. Rush, Technical Sergeant, Water Utilities/Water Treatment NCO, USAF 30th CES/CEOIU, Vandenberg Air Force Base, and James E. Zielinski ... Dave Savinsky, Environmental Consultant, 30 CES/CEVC, Vandenberg Air Force Base, on the Preliminary Draft Ground-Based Midcourse Defense (GMD

  2. Modification of Modulating Anode Voltage Supply of Klystron for PEFP 20 MeV Linac

    International Nuclear Information System (INIS)

    Kim, Dae Il; Kwon, Hyeok Jung; Kim, Han Sung; Cho, Yong Sub

    2011-01-01

    The klystron (TH2089F, THALES) for PEFP 20MeV proton linear accelerator has a triode type electron gun and the modulating anode voltage should be supplied. The klystron has gone through some modification in the modulating anode voltage supply circuit. Formerly, the mod-anode voltage was supplied by using the tetrode-controlled voltage divider. This system requires addition power supply for the tetrode and the grid control circuit. Recently we modified the mod-anode supply from the tetrode-controlled voltage divider to a resistive voltage divider. The resistors for the previous voltage divider were installed at a supporter with high voltage bushing structure next to the klystron. In the previous system, the resistors were exposed to the air and their size was very bulky, length of which was about 1m long. To reduce the space occupied by the voltage divider and to improve the electrical insulation performance, the voltage dividing resistors were moved into the oil tank of the klystron. During the operation of the 20 MeV linac, the klystron parameters were measured. In this paper, the modification of the voltage divider and the operational characteristics of the klystron with modified voltage divider circuit are presented

  3. Supply chain integration and performance : the moderating effect of supply complexity

    NARCIS (Netherlands)

    Giménez, C.; van der Vaart, T.; van Donk, D.P.

    2012-01-01

    Purpose - The purpose of this paper is to investigate the effectiveness of supply chain integration in different contexts. More specifically, it aims to show that supply chain integration is only effective in buyer-supplier relationships characterised by high supply complexity.

  4. Air compliance through pollution prevention at Air Force Materiel Command facilities.

    Energy Technology Data Exchange (ETDEWEB)

    Kolpa, R.; Ryckman, S.J. Jr.; Smith, A.E.

    1999-03-19

    Options for air compliance through pollution prevention (P2) have been identified at 14 facilities of the US Air Force Materiel Command, ranging from depots with significant light industrial activity to laboratories. Previous P2 efforts concentrated on reducing hazardous and solid wastes, with any reduction in air impacts generally being a collateral benefit. This work focused on reducing air emissions and air compliance vulnerabilities. P2 options were identified in three stages. First, potentially applicable P2 options were identified from Internet and published information. Attention was given to identifying the types of sources to which an option could be applied, the option's state of development, and constraints that could limit its application. Traditional P2 options involving technology or equipment changes and material substitution were considered. In addition, newer approaches based on administrative ''controls'' were considered. These included inserting P2 into operating permits in exchange for administrative relief, privatization, derating boilers, and reducing an installation's potential to emit and compliance vulnerability by separating sources not under the Air Force's ''common control.'' Next, criteria and toxic emissions inventories by source category were prepared from inventory data supplied by facilities. The major problems at this stage were differences in the levels of detail provided by facilities and in the categories used by different installations. Emitting categories were matched to P2 option categories to identify candidate options. Candidates were screened to account for local regulations and technical information about sources in the inventories. When possible, emission reductions were estimated to help facility personnel prioritize options. Some options identified are being actively pursued by facilities to determine their site-specific feasibility. Although much work has been

  5. Dynamic Modeling of Kosovo's Electricity Supply-Demand, Gaseous Emissions and Air Pollution

    Directory of Open Access Journals (Sweden)

    Sadik Bekteshi

    2015-09-01

    Full Text Available In this paper is described the developing of an integrated electricity supply–demand, gaseous emission and air pollution model for study of possible baseline electricity developments and available options to mitigate emissions. This model is constructed in STELLA software, which makes use of Systems Dynamics Modeling as the methodology. Several baseline scenarios have been developed from this model and a set of options of possible developments of Kosovo's Electricity Supply–Demand and Gaseous Emissions are investigated. The analysis of various scenarios results in medium growth scenarios (MGS that imply building of generation capacities and increase in participation of the electricity generation from renewable sources. MGS would be 10% of the total electricity generation and ensure sustainable development of the electricity sector. At the same time, by implementation of new technologies, this would be accompanied by reduced GHG (CO2 and NOx emissions by 60% and significant reduction for air pollutants (dust and SO2 by 40% compared to the business-as-usual (BAU case. Conclusively, obtained results show that building of new generation capacities by introducing new technologies and orientation on environmentally friendly energy sources can ensure sustainable development of the electricity sector in Kosovo.  

  6. Experimental investigation of a super performance dew point air cooler

    International Nuclear Information System (INIS)

    Xu, Peng; Ma, Xiaoli; Zhao, Xudong; Fancey, Kevin

    2017-01-01

    Highlights: •The cooler had a complex heat & mass exchanger with an advanced wet material layer. •Intermittent water supply scheme was implemented. •The cooler achieved 100–160% higher COP compared to the existing dew point coolers. •Electricity use of the cooler was reduced by 50–70% compared to existing dew coolers. •This optimal working air ratio was 0.364 that enabled maximised cooling effectiveness. -- Abstract: This paper presents an experimental investigation of a super performance dew point air cooler which, by employing a super performance wet material layer, innovative heat and mass exchanger and intermittent water supply scheme, has achieved a significantly higher energy efficiency (i.e. Coefficient of Performance, COP) and a much lower electrical energy use compared to the existing air coolers of the same type. This involves the dedicated system design & construction, fully planned experimental testing under various simulated climatic conditions representing the climate of hot & dry, warm & dry, moderate, warm & humid and standard lab testing condition, testing results analysis and discussion, as well as the parallel comparison against the commercial dew point air cooler. Under the standard test condition, i.e. dry bulb temperature of 37.8 °C and coincident wet bulb temperature of 21.1 °C, the prototype cooler achieved the wet-bulb cooling effectiveness of 114% and dew-point cooling effectiveness of 75%, yielding a significantly high COP value of 52.5 at the optimal working air ratio of 0.364. The testing also indicated that the lower inlet air relative humidity led to a higher cooling efficiency, while the lower cooling output helped increase COP and cooling effectiveness (including the wet-bulb effectiveness and dew-point effectiveness) of the cooler.

  7. Performance analysis of a direct expansion air dehumidification system combined with membrane-based total heat recovery

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Cai-Hang; Zhang, Li-Zhi; Pei, Li-Xia [Key Laboratory of Enhanced Heat Transfer and Energy Conservation of Education Ministry, School of Chemistry and Chemical Engineering, South China University of Technology, Guangzhou 510640 (China)

    2010-09-15

    A direct expansion (DX) air dehumidification system is an efficient way to supply fresh and dry air to a built environment. It plays a key role in preventing the spread of respiratory disease like Swine flu (H1N1). To improve the efficiency of a conventional DX system in hot and humid regions, a new system of DX in combination with a membrane-based total heat exchanger is proposed. Air is supplied with dew points. A detailed mathematical modeling is performed. A cell-by-cell simulation technique is used to simulate its performances. A real prototype is built in our laboratory in South China University of Technology to validate the model. The effects of inlet air humidity and temperature, evaporator and condenser sizes on the system performance are investigated. The results indicate that the model can predict the system accurately. Compared to a conventional DX system, the air dehumidification rate (ADR) of the novel system is 0.5 times higher, and the coefficient of performance (COP) is 1 times higher. Furthermore, the system performs well even under harsh hot and humid weather conditions. (author)

  8. Building America Case Study: Air Leakage and Air Transfer Between Garage and Living Space, Waldorf, Maryland (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2014-11-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

  9. Making water out of thin air

    International Nuclear Information System (INIS)

    Wallace, Paula

    2013-01-01

    gas is $5.60/ gigajoule, electricity can be produced for as little as $0.07/kWh. But if diesel is $1.20/litre, electricity is produced at $0.50/kWh. Water and heat are essentially produced for free. “Compared to using grid purchased electricity, with an efficiency of 33%, to achieve the same number of energy products, MulitGen achieves efficiencies up to 95%,” said WES CEO Wallie Ivison. That is, 95% of the energy contained in the natural gas fuel burned in the MultiGen turbine component is said to be turned into usable energy. This is achieved by capturing the exhaust gas heat released by the turbine to power air-cooled gas absorption chillers which operate the air water technology. The by-product of this technology is air- conditioned air. If required, MultiGen cangive an additional output of heating site water using a gas-electric process. Electrical power generated through the inverter system is considered 'clean' power. Some grid supplied electricity averages a power factor of only 0.75; MultiGen's power factor of electricity supplied is 0.98. “This means that electrical equipment can operate more efficiently drawing less current, aiding in a further reduction of grid supply requirements,” said Ivison. Working in optimal conditions MultiGen systems can provide 50-4000 litres of water from air; 120kW to 1500kW of heat energy; air conditioning to 300-160,000 square meters of space; and 30kW-10MW of power. The economic and environmental savings are determined by a number of factors as the systems must be designed specifically for each site. But the MultiGen system sits somewhere in between an internal combustion engine and photovoltaic solar in terms of capital expenditure. “If you're running just the basics you're looking at a 60-65% saving in energy costs,” said Sharon. For smaller models (water, air and power) the CO2 savings could be 125 tonnes; for larger models (water, air, power and water heating) around 7504 tonnes.

  10. Air Muscle Actuated Low Cost Humanoid Hand

    Directory of Open Access Journals (Sweden)

    Peter Scarfe

    2008-11-01

    Full Text Available The control of humanoid robot hands has historically been expensive due to the cost of precision actuators. This paper presents the design and implementation of a low-cost air muscle actuated humanoid hand developed at Curtin University of Technology. This hand offers 10 individually controllable degrees of freedom ranging from the elbow to the fingers, with overall control handled through a computer GUI. The hand is actuated through 20 McKibben-style air muscles, each supplied by a pneumatic pressure-balancing valve that allows for proportional control to be achieved with simple and inexpensive components. The hand was successfully able to perform a number of human-equivalent tasks, such as grasping and relocating objects.

  11. Air Muscle Actuated Low Cost Humanoid Hand

    Directory of Open Access Journals (Sweden)

    Peter Scarfe

    2006-06-01

    Full Text Available The control of humanoid robot hands has historically been expensive due to the cost of precision actuators. This paper presents the design and implementation of a low-cost air muscle actuated humanoid hand developed at Curtin University of Technology. This hand offers 10 individually controllable degrees of freedom ranging from the elbow to the fingers, with overall control handled through a computer GUI. The hand is actuated through 20 McKibben-style air muscles, each supplied by a pneumatic pressure-balancing valve that allows for proportional control to be achieved with simple and inexpensive components. The hand was successfully able to perform a number of human-equivalent tasks, such as grasping and relocating objects.

  12. Cold Vacuum Drying facility heating, ventilation, and Air Conditioning system design description

    International Nuclear Information System (INIS)

    SINGH, G.

    2000-01-01

    This System Design Description (SDD) addresses the HVAC system for the CVDF. The CVDF HVAC system consists of five subsystems: (1) Administration building HVAC system; (2) Process bay recirculation HVAC system; (3) Process bay local exhaust HVAC and process vent system; (4) Process general supply/exhaust HVAC system; and (5) Reference air system. The HVAC and reference air systems interface with the following systems: the fire protection control system, Monitoring and Control System (MCS), electrical power distribution system (including standby power), compressed air system, Chilled Water (CHW) system, drainage system, and other Cold Vacuum Drying (CVD) control systems not addressed in this SDD

  13. Assessment of the Energy Impacts of Outside Air in the Commercial Sector

    Energy Technology Data Exchange (ETDEWEB)

    Benne, K.; Griffith, B.; Long, N.; Torcellini, P.; Crawley, D.; Logee, T.

    2009-04-01

    The enormous quantity of energy consumed by U.S. commercial buildings places a significant burden on the energy supply and is a potential source of economic strain. To address this, the DOE Building Technologies Program has established the goal of developing market-viable zero energy buildings by 2025. This study focuses on the effects of outside air, and considers various outside air sources, types of building construction, building subsectors, and climates. Based on the information about energy consumption attributed to outside air, it identifies topics for further research that have the greatest potential to achieve energy savings.

  14. Performance and Effectiveness of Portable Air Cleaners in an Office Room

    DEFF Research Database (Denmark)

    Ardkapan, Siamak Rahimi; Afshari, Alireza; Bergsøe, Niels Christian

    2015-01-01

    Nowadays, many people work in an office environment. Air pollutants, including particles and gases, are generated by humans and by different devices that are used in offices. Pollutants can also enter an office room with the air supplied from outdoors. It has been established that air pollutants...... and particles in an office room. The particle removal effectiveness of the technologies was also determined in order to clarify their ability to remove UFPs (ultrafine particles) in the office room. The tested five air cleaning technologies are non-thermal plasma, corona discharge ionizer, portable air purifier......, electrostatic fibrous filter and three-dimensional fibrous filter. The interior surfaces of the office room emit low levels of volatile organic compounds, since the office room has not been refurbished for about two decades. The results showed that the particle removal effectiveness of the technologies...

  15. Pengukuran Kinerja Supply Chain Dengan Pendekatan Supply Chain Operation References (SCOR

    Directory of Open Access Journals (Sweden)

    Rizki Wahyuniardi

    2017-12-01

    Full Text Available PT. Brodo Ganesha Indonesia is a national company engaged in manufacturing with the production of leather shoes. The company has many stakeholders and it is difficult to manage its supply chain, thereby affecting the effectiveness and efficiency of the company's supply chains. The research was conducted to measure the performance of supply chain by using Supply Chain Operation References (SCOR approach. The initial hierarchy model of performance measurement is tailored to the company's condition to measure its supply chain performance, while the normalization of Snorm De Boer serves to equalize the value of the matrix used as the measurement indicator. The level of importance of performance attributes is measured by weighting with subjective questionnaires. Value of performance attribute obtained reliability 19,74, responsiveness 16,91, agility 11,00; and asset management 12.26. The total performance score of 59.90. This value indicates that the performance of the supply chain is in an average position.

  16. Development of a small air-cooled ``midnight sun'' thermophotovoltaic electric generator

    Science.gov (United States)

    Fraas, Lewis M.; Xiang, Huang Han; Hui, She; Ferguson, Luke; Samaras, John; Ballantyne, Russ; Seal, Michael; West, Ed

    1996-02-01

    A natural gas fired thermophotovoltaic generator using infrared-sensitive GaSb cells and a silicon carbide emitter is described. The emitter is designed to operate at 1400 °C. Twelve GaSb receivers surround the emitter. Each receiver contains a string of series connected cells. Special infrared filters are bonded to each cell. These filters transmit short wavelength useful IR to the cells while reflecting longer wavelength IR back to the emitter. Combustion air is supplied to the burner through a counterflow heat exchanger where the air is preheated by the exhaust from the burner. The unit is air cooled and designed to produce approximately 100 Watts of electric power.

  17. Performance analysis of proposed hybrid air conditioning and humidification–dehumidification systems for energy saving and water production in hot and dry climatic regions

    International Nuclear Information System (INIS)

    Nada, S.A.; Elattar, H.F.; Fouda, A.

    2015-01-01

    Highlights: • Integrative air-conditioning (A/C) and humidification–dehumidification desalination systems are proposed. • Effects of operating parameters on the proposed systems are investigated. • System configurations that have the highest fresh water production rate, power saving and total cost saving are identified. - Abstract: Performance of integrative air-conditioning (A/C) and humidification–dehumidification desalination systems proposed for hot and dry climatic regions is theoretically investigated. The proposed systems aim to energy saving and systems utilization in fresh water production. Four systems with evaporative cooler and heat recovery units located at different locations are proposed, analyzed and evaluated at different operating parameters (fresh air ratio, supply air temperature and outside air wet bulb temperature). Other two basic systems are used as reference systems in proposed systems assessment. Fresh water production rate, A/C cooling capacity, A/C electrical power consumption, saving in power consumptions and total cost saving (TCS) parameters are used for systems evaluations and comparisons. The results show that (i) the fresh water production rates of the proposed systems increase with increasing fresh air ratio, supply air temperature and outdoor wet bulb temperature, (ii) powers saving of the proposed systems increase with increasing fresh air ratio and supply air temperature and decreasing of the outdoor air wet bulb temperature, (iii) locating the evaporative cooling after the fresh air mixing remarkably increases water production rate, and (vi) incorporating heat recovery in the air conditioning systems with evaporative cooling may adversely affect both of the water production rate and the total cost saving of the system. Comparison study has been presented to identify systems configurations that have the highest fresh water production rate, highest power saving and highest total cost saving. Numerical correlations for

  18. The supply problem of the allies; Quand l'or noir coulait a flots

    Energy Technology Data Exchange (ETDEWEB)

    Baudoin, Ph.

    2004-07-01

    Owing to unprecedented mechanization, everything to do with petroleum supplies had a crucial role to play in World War II. In the wake of Operation Overlord, the battle grounds of Normandy saw technologies deployed on a huge scale. Logistics were a major problem whether fighting in the air or on the ground, with oil and fuel supplies a critical element. With no fuel, this gigantic military operation could never have been carried through, for with aircraft grounded and tanks grinding to a halt, all would soon have been lost. Accordingly, the Allies made bold logistical plans, which nevertheless had shortcomings calling for improvisation. The cross-Channel pipeline PLUTO, the impressive stream of road traffic known as the Red Ball Express, rapid repairs to the railroads, trains of barges on the Seine, DC-3s transporting oil and fuel, were all pieces in the jigsaw puzzle bringing supplies to Allied units on their way across Normandy in 1944. (A.L.B.)

  19. Effective food supply chains : generating, modelling and evaluating supply chain scenarios

    NARCIS (Netherlands)

    Vorst, van der J.G.A.J.

    2000-01-01

    Logistical co-ordination in FMCG supply chains

    The overall objectives of the research described in this thesis were to obtain insight into the applicability of the concept Supply Chain Management (SCM) in food supply chains (SCs) from a logistical point of view, and to

  20. A RADIANT AIR-CONDITIONING SYSTEM USING SOLAR-DRIVEN

    Directory of Open Access Journals (Sweden)

    S. A. ABDALLA

    2006-12-01

    Full Text Available Every air-conditioning system needs some fresh air to provide adequate ventilation air required to remove moisture, gases like ammonia and hydrogen sulphide, disease organisms, and heat from occupied spaces. However, natural ventilation is difficult to control because urban areas outside air is often polluted and cannot be supplied to inner spaces before being filtered. Besides the high electrical demand of refrigerant compression units used by most air-conditioning systems, and fans used to transport the cool air through the thermal distribution system draw a significant amount of electrical energy in comparison with electrical energy used by the building thermal conditioning systems. Part of this electricity heats the cooled air; thereby add to the internal thermal cooling peak load. In addition, refrigerant compression has both direct and indirect negative effects on the environment on both local and global scales. In seeking for innovative air-conditioning systems that maintain and improve indoor air quality under potentially more demanding performance criteria without increasing environmental impact, this paper presents radiant air-conditioning system which uses a solar-driven liquid desiccant evaporative cooler. The paper describes the proposed solar-driven liquid desiccant evaporative cooling system and the method used for investigating its performance in providing cold water for a radiant air-conditioning system in Khartoum (Central Sudan. The results of the investigation show that the system can operate in humid as well as dry climates and that employing such a system reduces air-conditioning peak electrical demands as compared to vapour compression systems.