WorldWideScience

Sample records for superior thermal ionization

  1. Thermal ionization of Cs Rydberg states

    Science.gov (United States)

    Glukhov, I. L.; Ovsiannikov, V. D.

    2009-01-01

    Rates Pnl of photoionization from Rydberg ns-, np-, nd-states of a valence electron in Cs, induced by black-body radiation, were calculated on the basis of the modified Fues model potential method. The numerical data were approximated with a three-term expression which reproduces in a simple analytical form the dependence of Pnl on the ambient temperature T and on the principal quantum number n. The comparison between approximate and exactly calculated values of the thermal ionization rate demonstrates the applicability of the proposed approximation for highly excited states with n from 20 to 100 in a wide temperature range of T from 100 to 10,000 K. We present coefficients of this approximation for the s-, p- and d-series of Rydberg states.

  2. Spatially resolved thermal desorption/ionization coupled with mass spectrometry

    Science.gov (United States)

    Jesse, Stephen; Van Berkel, Gary J; Ovchinnikova, Olga S

    2013-02-26

    A system and method for sub-micron analysis of a chemical composition of a specimen are described. The method includes providing a specimen for evaluation and a thermal desorption probe, thermally desorbing an analyte from a target site of said specimen using the thermally active tip to form a gaseous analyte, ionizing the gaseous analyte to form an ionized analyte, and analyzing a chemical composition of the ionized analyte. The thermally desorbing step can include heating said thermally active tip to above 200.degree. C., and positioning the target site and the thermally active tip such that the heating step forms the gaseous analyte. The thermal desorption probe can include a thermally active tip extending from a cantilever body and an apex of the thermally active tip can have a radius of 250 nm or less.

  3. Development of a thermal ionizer as ion catcher

    Energy Technology Data Exchange (ETDEWEB)

    Traykov, Emil; Dermois, Otto; Hoek, Duurt-Jan van der; Jungmann, Klaus; Kruithof, Wilbert; Mol, Aran; Onderwater, Gerco; Silva, Marlene di; Sohani, Moslem; Versolato, Oscar; Willmann, Lorenz; Wilschut, Hans [Kernfysisch Versneller Instituut, University of Groningen (Netherlands)

    2008-07-01

    An effective ion catcher is an important part of a radioactive beam facility that is based on in-flight production. The catcher stops fast radioactive products and emits them as singly charged slow ions. Current ion catchers are based on stopping in He gas. However, with increasing intensity of the secondary beam the amount of ion-electron pairs created eventually prevents the electromagnetic extraction of the radioactive ions from the gas cell. In contrast, such limitations are not present in thermal ionizers used with the ISOL production technique. Therefore, at least for alkaline and alkaline earth elements, a thermal ionizer should then be preferred. An important use of the TRI{mu}P facility at KVI will be for precision measurements using atom traps. Atom trapping is particularly possible for alkaline and alkaline earth isotopes. Therefore, we have built and tested a thermal ionizer. Using a radioactive beam of {sup 21}Na of about 20 MeV/nucleon, the temperature dependence and throughput of the ionizer catcher was characterized. The results are presented.

  4. Laser-Induced Ionization Efficiency Enhancement On A Filament For Thermal Ionization Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Siegfried, M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-10-14

    The evaluation of trace Uranium and Plutonium isotope ratios for nanogram to femtogram material quantities is a vital tool for nuclear counter-proliferation and safeguard activities. Thermal Ionization Mass Spectrometry (TIMS) is generally accepted as the state of the art technology for highly accurate and ultra-trace measurements of these actinide ratios. However, the very low TIMS ionization yield (typically less than 1%) leaves much room for improvement. Enhanced ionization of Nd and Sm from a TIMS filament was demonstrated using wavelength resonance with a nanosecond (pulse width) laser operating at 10 Hz when light was directed toward the filament.1 For this study, femtosecond and picosecond laser capabilities were to be employed to study the dissociation and ionization mechanisms of actinides/lanthanides and measure the enhanced ionization of the metal of interest. Since the underlying chemistry of the actinide/lanthanide carbides produced and dissociated on a TIMS filament is not well understood, the experimental parameters affecting the photodissociation and photoionization with one and two laser beams were to be investigated.

  5. Measurement of boron isotopes by negative thermal ionization mass spectrometry

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The isobaric interference for boron isotopic measurement by negative thermal ionization mass spectrometry (NTIMS) has been studied. The result shows that the CNO- is not only from the organic material, but also from nitrate in loading reagent in NTIMS. Monitoring the mass 43 ion intensity and 43/42 ratio of blank are also necessary for the boron isotopic measurement by NTIMS, other than is only boron content.

  6. Development of a thermal ionizer as ion catcher

    CERN Document Server

    Traykov, E; De, S; Dermois, O C; Huisman, L; Jungmann, K; Kruithof, W; Mol, A J; Onderwater, C J G; Rogachevskiy, A; Silva, M da Silva e; Sohani, M; Versolato, O; Willmann, L; Wilschut, H W

    2007-01-01

    An effective ion catcher is an important part of a radioactive beam facility that is based on in-flight production. The catcher stops fast radioactive products and emits them as singly charged slow ions. Current ion catchers are based on stopping in He and H$_2$ gas. However, with increasing intensity of the secondary beam the amount of ion-electron pairs created eventually prevents the electromagnetic extraction of the radioactive ions from the gas cell. In contrast, such limitations are not present in thermal ionizers used with the ISOL production technique. Therefore, at least for alkaline and alkaline earth elements, a thermal ionizer should then be preferred. An important use of the TRI$\\mu$P facility will be for precision measurements using atom traps. Atom trapping is particularly possible for alkaline and alkaline earth isotopes. The facility can produce up to 10$^9$ s$^{-1}$ of various Na isotopes with the in-flight method. Therefore, we have built and tested a thermal ionizer. An overview of the ope...

  7. About AGN ionization echoes, thermal echoes, and ionization deficits in low redshift Lyman-alpha blobs

    CERN Document Server

    Schirmer, Mischa; Levenson, Nancy A; Fu, Hai; Davies, Rebecca L; Keel, William C; Torrey, Paul; Bennert, Vardha N; Pancoast, Anna; Turner, James E H

    2016-01-01

    We report the discovery of 14 Lyman-alpha blobs (LABs) at z~0.3, existing at least 4-7 billion years later in the Universe than all other LABs known. Their optical diameters are 20-70 kpc, and GALEX data imply Ly-alpha luminosities of (0.4-6.3)x10^43 erg/s. Contrary to high-z LABs, they live in low-density areas. They are ionized by AGN, suggesting that cold accretion streams as a power source must deplete between z=2 and z=0.3. We also show that transient AGN naturally explain the ionization deficits observed in many LABs: Their Ly-alpha and X-ray fluxes decorrelate below 10^6 years because of the delayed escape of resonantly scattering Ly-alpha photons. High Ly-alpha luminosities do not require currently powerful AGN, independent of obscuration. Chandra X-ray data reveal intrinsically weak AGN, confirming the luminous optical nebulae as impressive ionization echoes. For the first time, we also report mid-infrared thermal echoes from the dusty tori. We conclude that the AGN have faded by 3-4 orders of magnit...

  8. Soft ionization of thermally evaporated hypergolic ionic liquid aerosols

    Energy Technology Data Exchange (ETDEWEB)

    University of California; ERC, Incorporated, Edwards Air Force Base; Air Force Research Laboratory, Edwards Air Force Base; National Synchrotron Radiation Research Center (NSRRC); Institute of Chemistry, Hebrew University; Koh, Christine J.; Liu, Chen-Lin; Harmon, Christopher W.; Strasser, Daniel; Golan, Amir; Kostko, Oleg; Chambreau, Steven D.; Vaghjiani, Ghanshyam L.; Leone, Stephen R.

    2011-07-19

    Isolated ion pairs of a conventional ionic liquid, 1-Ethyl-3-Methyl-Imidazolium Bis(trifluoromethylsulfonyl)imide ([Emim+][Tf2N?]), and a reactive hypergolic ionic liquid, 1-Butyl-3-Methyl-Imidazolium Dicyanamide ([Bmim+][Dca?]), are generated by vaporizing ionic liquid submicron aerosol particles for the first time; the vaporized species are investigated by dissociative ionization with tunable vacuum ultraviolet (VUV) light, exhibiting clear intact cations, Emim+ and Bmim+, presumably originating from intact ion pairs. Mass spectra of ion pair vapor from an effusive source of the hypergolic ionic liquid show substantial reactive decomposition due to the internal energy of the molecules emanating from the source. Photoionization efficiency curves in the near threshold ionization region of isolated ion pairs of [Emim+][Tf2N?]ionic liquid vapor are compared for an aerosol source and an effusive source, revealing changes in the appearance energy due to the amount of internal energy in the ion pairs. The aerosol source has a shift to higher threshold energy (~;;0.3 eV), attributed to reduced internal energy of the isolated ion pairs. The method of ionic liquid submicron aerosol particle vaporization, for reactive ionic liquids such as hypergolic species, is a convenient, thermally ?cooler? source of isolated intact ion pairs in the gas phase compared to effusive sources.

  9. Soft Ionization of Thermally Evaporated Hypergolic Ionic Liquid Aerosols

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Christine J. [Univ. of California, Berkeley, CA (United States); Liu, Chen-Lin [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Harmon, Christopher W. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Strasser, Daniel [Univ. of California, Berkeley, CA (United States); Golan, Amir [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Kostko, Oleg [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Chambreau, Steven D. [Edwards Air Force Base, ERC Inc., CA (United States); Vaghjiani, Ghanshyam L. [Air Force Research Laboratory, Edwards Air Force Base, CA (United States); Leone, Stephen R. [Univ. of California, Berkeley, CA (United States); Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2011-04-20

    Isolated ion pairs of a conventional ionic liquid, 1-Ethyl-3-Methyl-Imidazolium Bis(trifluoromethylsulfonyl)imide ([Emim+][Tf2N–]), and a reactive hypergolic ionic liquid, 1-Butyl-3-Methyl-Imidazolium Dicyanamide ([Bmim+][Dca–]), are generated by vaporizing ionic liquid submicrometer aerosol particles for the first time; the vaporized species are investigated by dissociative ionization with tunable vacuum ultraviolet (VUV) light, exhibiting clear intact cations, Emim+ and Bmim+, presumably originating from intact ion pairs. Mass spectra of ion pair vapor from an effusive source of the hypergolic ionic liquid show substantial reactive decomposition due to the internal energy of the molecules emanating from the source. Also, hotoionization efficiency curves in the near threshold ionization region of isolated ion pairs of [Emim+][Tf2N] ionic liquid vapor are compared for an aerosol source and an effusive source, revealing changes in the appearance energy due to the amount of internal energy in the ion pairs. The aerosol source has a shift to higher threshold energy (~0.3 eV), attributed to reduced internal energy of the isolated ion pairs. Lastly, the method of ionic liquid submicrometer aerosol particle vaporization, for reactive ionic liquids such as hypergolic species, is a convenient, thermally “cooler” source of isolated intact ion pairs in the gas phase compared to effusive sources.

  10. Soft Ionization of Thermally Evaporated Hypergolic Ionic Liquid Aerosols

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Christine J. [Univ. of California, Berkeley, CA (United States); Liu, Chen-Lin [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Harmon, Christopher W. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Strasser, Daniel [Univ. of California, Berkeley, CA (United States); Golan, Amir [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Kostko, Oleg [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Chambreau, Steven D. [Edwards Air Force Base, ERC Inc., CA (United States); Vaghjiani, Ghanshyam L. [Air Force Research Laboratory, Edwards Air Force Base, CA (United States); Leone, Stephen R. [Univ. of California, Berkeley, CA (United States); Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2011-04-20

    Isolated ion pairs of a conventional ionic liquid, 1-Ethyl-3-Methyl-Imidazolium Bis(trifluoromethylsulfonyl)imide ([Emim+][Tf2N–]), and a reactive hypergolic ionic liquid, 1-Butyl-3-Methyl-Imidazolium Dicyanamide ([Bmim+][Dca–]), are generated by vaporizing ionic liquid submicrometer aerosol particles for the first time; the vaporized species are investigated by dissociative ionization with tunable vacuum ultraviolet (VUV) light, exhibiting clear intact cations, Emim+ and Bmim+, presumably originating from intact ion pairs. Mass spectra of ion pair vapor from an effusive source of the hypergolic ionic liquid show substantial reactive decomposition due to the internal energy of the molecules emanating from the source. Also, hotoionization efficiency curves in the near threshold ionization region of isolated ion pairs of [Emim+][Tf2N] ionic liquid vapor are compared for an aerosol source and an effusive source, revealing changes in the appearance energy due to the amount of internal energy in the ion pairs. The aerosol source has a shift to higher threshold energy (~0.3 eV), attributed to reduced internal energy of the isolated ion pairs. Lastly, the method of ionic liquid submicrometer aerosol particle vaporization, for reactive ionic liquids such as hypergolic species, is a convenient, thermally “cooler” source of isolated intact ion pairs in the gas phase compared to effusive sources.

  11. Soft ionization of thermally evaporated hypergolic ionic liquid aerosols

    Energy Technology Data Exchange (ETDEWEB)

    University of California; ERC, Incorporated, Edwards Air Force Base; Air Force Research Laboratory, Edwards Air Force Base; National Synchrotron Radiation Research Center (NSRRC); Institute of Chemistry, Hebrew University; Koh, Christine J.; Liu, Chen-Lin; Harmon, Christopher W.; Strasser, Daniel; Golan, Amir; Kostko, Oleg; Chambreau, Steven D.; Vaghjiani, Ghanshyam L.; Leone, Stephen R.

    2011-07-19

    Isolated ion pairs of a conventional ionic liquid, 1-Ethyl-3-Methyl-Imidazolium Bis(trifluoromethylsulfonyl)imide ([Emim+][Tf2N?]), and a reactive hypergolic ionic liquid, 1-Butyl-3-Methyl-Imidazolium Dicyanamide ([Bmim+][Dca?]), are generated by vaporizing ionic liquid submicron aerosol particles for the first time; the vaporized species are investigated by dissociative ionization with tunable vacuum ultraviolet (VUV) light, exhibiting clear intact cations, Emim+ and Bmim+, presumably originating from intact ion pairs. Mass spectra of ion pair vapor from an effusive source of the hypergolic ionic liquid show substantial reactive decomposition due to the internal energy of the molecules emanating from the source. Photoionization efficiency curves in the near threshold ionization region of isolated ion pairs of [Emim+][Tf2N?]ionic liquid vapor are compared for an aerosol source and an effusive source, revealing changes in the appearance energy due to the amount of internal energy in the ion pairs. The aerosol source has a shift to higher threshold energy (~;;0.3 eV), attributed to reduced internal energy of the isolated ion pairs. The method of ionic liquid submicron aerosol particle vaporization, for reactive ionic liquids such as hypergolic species, is a convenient, thermally ?cooler? source of isolated intact ion pairs in the gas phase compared to effusive sources.

  12. Soft ionization of thermally evaporated hypergolic ionic liquid aerosols.

    Science.gov (United States)

    Koh, Christine J; Liu, Chen-Lin; Harmon, Christopher W; Strasser, Daniel; Golan, Amir; Kostko, Oleg; Chambreau, Steven D; Vaghjiani, Ghanshyam L; Leone, Stephen R

    2011-05-12

    Isolated ion pairs of a conventional ionic liquid, 1-Ethyl-3-Methyl-Imidazolium Bis(trifluoromethylsulfonyl)imide ([Emim(+)][Tf(2)N(-)]), and a reactive hypergolic ionic liquid, 1-Butyl-3-Methyl-Imidazolium Dicyanamide ([Bmim(+)][Dca(-)]), are generated by vaporizing ionic liquid submicrometer aerosol particles for the first time; the vaporized species are investigated by dissociative ionization with tunable vacuum ultraviolet (VUV) light, exhibiting clear intact cations, Emim(+) and Bmim(+), presumably originating from intact ion pairs. Mass spectra of ion pair vapor from an effusive source of the hypergolic ionic liquid show substantial reactive decomposition due to the internal energy of the molecules emanating from the source. Photoionization efficiency curves in the near threshold ionization region of isolated ion pairs of [Emim(+)][Tf(2)N(-)] ionic liquid vapor are compared for an aerosol source and an effusive source, revealing changes in the appearance energy due to the amount of internal energy in the ion pairs. The aerosol source has a shift to higher threshold energy (∼0.3 eV), attributed to reduced internal energy of the isolated ion pairs. The method of ionic liquid submicrometer aerosol particle vaporization, for reactive ionic liquids such as hypergolic species, is a convenient, thermally "cooler" source of isolated intact ion pairs in the gas phase compared to effusive sources.

  13. Superior Thermal Barrier Coatings Using Solution Precursor Plasma Spray

    Science.gov (United States)

    Jordan, E. H.; Xie, L.; Gell, M.; Padture, N. P.; Cetegen, B.; Ozturk, A.; Ma, X.; Roth, J.; Xiao, T. D.; Bryant, P. E. C.

    2004-03-01

    A novel process, solution precursor plasma spray (SPPS), is presented for depositing thermal barrier coatings (TBCs), in which aqueous chemical precursors are injected into a standard direct current plasma spray system. The resulting coatings microstructure has three unique features: (1) ultra fine splats (1 µm), (2) nanometer and micron-sized interconnected porosity, and (3) closely spaced, through-thickness cracks. Coatings over 3 mm thick can be readily deposited using the SPPS process. Coating durability is excellent, with SPPS coatings showing, in furnace cycling tests, 2.5 times the spallation life of air plasma coatings (APS) and 1.5 times the life of electron beam physical vapor deposited (EB-PVD) coatings. The conductivity of SPPS coatings is lower than EB-PVD coatings and higher than the best APS coatings. Manufacturing cost is expected to be similar to APS coatings and much lower than EB-PVD coatings. The SPPS deposition process includes droplet break-up and material arriving at the deposition surface in various physical states ranging from aqueous solution, gel phase, to fully-molten ceramic. The relation between the arrival state of the material and the microstructure is described.

  14. Influence of relaxation processes on the structure of a thermal boundary layer in partially ionized argon

    Energy Technology Data Exchange (ETDEWEB)

    van Dongen, M.E.H.; van Eck, R.B.P.; Hagebeuk, H.J.L.; Hirschberg, A.; Hutten-Mansfeld, A.C.B.; Jager, H.J.; Willems, J.F.H. (Technische Hogeschool Eindhoven (Netherlands))

    1981-08-01

    A model for the unsteady thermal boundary-layer development at the end wall of a shock tube, in partially ionized atmospheric argon, is proposed. Consideration is given to ionization and thermal relaxation processes. In order to obtain some insight into the influence of the relaxation processes on the structure of the boundary layer, a study of the frozen and equilibrium limits has been carried out. The transition from a near-equilibrium situation in the outer part of the boundary layer towards a frozen situation near the wall is determined numerically. Experimental data on the electron and atom density profiles obtained from laser schlieren and absorption measurements are presented. A quantitative agreement between theory and experiment is found for a moderate degree of ionization (3%). At a higher degree of ionization the structure of the boundary layer is dominated by the influence of radiation cooling, which has been neglected in the model.

  15. Determination of equilibrium composition of thermally ionized monoatomic gas under different physical conditions

    Science.gov (United States)

    Romanova, M. S.; Rydalevskaya, M. A.

    2017-05-01

    Perfect gas mixtures that result from thermal ionization of spatially and chemically homogeneous monoatomic gases are considered. Equilibrium concentrations of the components of such mixtures are determined using integration over the momentum space and summation with respect to energy levels of the distribution functions that maximize the entropy of system under condition for constancy of the total number of nuclei and electrons. It is demonstrated that such a method allows significant simplification of the calculation of the equilibrium composition for ionized mixtures at different temperatures and makes it possible to study the degree of ionization of gas versus gas density and number in the periodic table of elements.

  16. About AGN ionization echoes, thermal echoes and ionization deficits in low-redshift Lyα blobs

    Science.gov (United States)

    Schirmer, Mischa; Malhotra, Sangeeta; Levenson, Nancy A.; Fu, Hai; Davies, Rebecca L.; Keel, William C.; Torrey, Paul; Bennert, Vardha N.; Pancoast, Anna; Turner, James E. H.

    2016-12-01

    We report the discovery of 14 Lyα blobs (LABs) at z ˜ 0.3, existing at least 4-7 billion years later in the Universe than all other LABs known. Their optical diameters are 20-70 kpc, and GALEX data imply Lyα luminosities of (0.4-6.3) × 1043 erg s-1. Contrary to high-z LABs, they live in low-density areas. They are ionized by AGN, suggesting that cold accretion streams as a power source must deplete between z = 2 and 0.3. We also show that transient AGN naturally explain the ionization deficits observed in many LABs. Their Lyα and X-ray fluxes decorrelate below ≲106 years because of the delayed escape of resonantly scattering Lyα photons. High Lyα luminosities do not require currently powerful AGN, independent of obscuration. Chandra X-ray data reveal intrinsically weak AGN, confirming the luminous optical nebulae as impressive ionization echoes. For the first time, we also report mid-infrared thermal echoes from the dusty tori. We conclude that the AGN have faded by three to four orders of magnitude within the last 104-5 years, leaving fossil UV, optical and thermal radiation behind. The host galaxies belong to the group of previously discovered Green Bean galaxies (GBs). Gemini optical imaging reveals smooth spheres, mergers, spectacular outflows and ionization cones. Because of their proximity and high flux densities, GBs are perfect targets to study AGN feedback, mode switching and the Lyα escape. The fully calibrated, co-added optical FITS images are publicly available.

  17. Validity boundary of orbital-free molecular dynamics method corresponding to thermal ionization of shell structure

    Science.gov (United States)

    Gao, Chang; Zhang, Shen; Kang, Wei; Wang, Cong; Zhang, Ping; He, X. T.

    2016-11-01

    With 6LiD as an example, we show that the applicable region of the orbital-free molecular dynamics (OFMD) method in a large temperature range is determined by the thermal ionization process of bound electrons in shell structures. The validity boundary of the OFMD method is defined roughly by the balance point of the average thermal energy of an electron and the ionization energy of the lowest localized electronic state. This theoretical proposition is based on the observation that the deviation of the OFMD method originates from its less accurate description to the charge density in partially ionized shells, as compared with the results of the extended first-principles molecular dynamics method, which well reproduces the charge density of shell structures.

  18. First-principles investigations on ionization and thermal conductivity of polystyrene for inertial confinement fusion applications

    Energy Technology Data Exchange (ETDEWEB)

    Hu, S. X., E-mail: shu@lle.rochester.edu; Goncharov, V. N.; McCrory, R. L.; Skupsky, S. [Laboratory for Laser Energetics, University of Rochester, 250 East River Road, Rochester, New York 14623 (United States); Collins, L. A.; Kress, J. D. [Theoretical Division, Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States)

    2016-04-15

    Using quantum molecular-dynamics (QMD) methods based on the density functional theory, we have performed first-principles investigations of the ionization and thermal conductivity of polystyrene (CH) over a wide range of plasma conditions (ρ = 0.5 to 100 g/cm{sup 3} and T = 15 625 to 500 000 K). The ionization data from orbital-free molecular-dynamics calculations have been fitted with a “Saha-type” model as a function of the CH plasma density and temperature, which gives an increasing ionization as the CH density increases even at low temperatures (T < 50 eV). The orbital-free molecular dynamics method is only used to gauge the average ionization behavior of CH under the average-atom model in conjunction with the pressure-matching mixing rule. The thermal conductivities (κ{sub QMD}) of CH, derived directly from the Kohn–Sham molecular-dynamics calculations, are then analytically fitted with a generalized Coulomb logarithm [(lnΛ){sub QMD}] over a wide range of plasma conditions. When compared with the traditional ionization and thermal conductivity models used in radiation–hydrodynamics codes for inertial confinement fusion simulations, the QMD results show a large difference in the low-temperature regime in which strong coupling and electron degeneracy play an essential role in determining plasma properties. Hydrodynamic simulations of cryogenic deuterium–tritium targets with CH ablators on OMEGA and the National Ignition Facility using the QMD-derived ionization and thermal conductivity of CH have predicted ∼20% variation in target performance in terms of hot-spot pressure and neutron yield (gain) with respect to traditional model simulations.

  19. [Real-time analysis of polyvinyl chloride thermal decomposition/combustion products with single photon ionization/photoelectron ionization online mass spectrometer].

    Science.gov (United States)

    Chen, Wen-Dong; Hou, Ke-Yong; Chen, Ping; Li, Fang-Long; Zhao, Wu-Duo; Cui, Hua-Peng; Hua, Lei; Xie, Yuan-Yuan; Li, Hai-Yang

    2013-01-01

    With the features of a broad range of ionizable compounds, reduced fragments and simple mass spectrum, a homemade magnetic field enhanced photoelectron ionization (MEPEI) source combined with single photon ionization (SPI) for time-of-flight mass spectrometer was built and applied to analyze thermal decomposition/combustion products of polyvinyl chloride (PVC). The combined ion source can be switched very fast between SPI mode and SPI-MEPEI mode for detecting different targeted compounds, and only adjusting the voltage of the electrode in the ionization region to trigger the switch. Among the PVC thermal decomposition/combustion products, HCl and CO2, which ionization energies (12.74 eV, 13.77 eV respectively) were higher than the energy of photon (10.60 eV), were ionized by MEPEI, while alkenes, dichloroethylene, benzene and its homologs, monochlorobenzene, styrene, indane, naphthalene and its homologs were ionized by SPI and MEPEI simultaneously. Spectra of interested products as a function of temperatures indicated that products are formed via two main mechanisms: (1) dechlorination and intramolecular cyclization can lead to the formation of HCl, benzene and naphthalene at 250-370 degrees C; (2) intermolecular crosslinking leads to the formation of alkyl aromatics such as toluene and xylene/ethylbenzene at 380-510 degrees C. The experimental results show that the combined ion source of SPI/ SPI-MEPEI for TOF-MS has broad application prospects in the online analysis field.

  20. Lignin-based carbon fibers: Carbon nanotube decoration and superior thermal stability

    KAUST Repository

    Xu, Xuezhu

    2014-08-23

    Lignin-based carbon fibers (CFs) decorated with carbon nanotubes (CNTs) were synthesized and their structure, thermal stability and wettability were systematically studied. The carbon fiber precursors were produced by electrospinning lignin/polyacrylonitrile solutions. CFs were obtained by pyrolyzing the precursors and CNTs were subsequently grown on the CFs to eventually achieve a CF–CNT hybrid structure. The processes of pyrolysis and CNT growth were conducted in a tube furnace using different conditions and the properties of the resultant products were studied and compared. The CF–CNT hybrid structure produced at 850 °C using a palladium catalyst showed the highest thermal stability, i.e., 98.3% residual weight at 950 °C. A mechanism for such superior thermal stability was postulated based on the results from X-ray diffraction, Raman spectroscopy, scanning and transmission electron microscopy, and electron energy loss spectroscopy analyses. The dense CNT decoration was found to increase the hydrophobicity of the CFs.

  1. Precursor ion scan profiles of acylcarnitines by atmospheric pressure thermal desorption chemical ionization tandem mass spectrometry.

    Science.gov (United States)

    Paglia, Giuseppe; D'Apolito, Oceania; Corso, Gaetano

    2008-12-01

    The fatty acyl esters of L-carnitine (acylcarnitines) are useful biomarkers for the diagnosis of some inborn errors of metabolism analyzed by liquid chromatography/tandem mass spectrometry. In this study the acylcarnitines were analyzed by atmospheric pressure thermal desorption chemical ionization using a commercial tandem mass spectrometer (APTDCI-MS/MS). The method is based on the precursor ion scan mode determination of underivatized acylcarnitines desorbed from samples by a hot desolvation gas flow and ionized by a corona pin discharge. During desorption/ionization step the temperature induces the degradation of acylcarnitines; nevertheless, the common fragment to all acylcarnitines [MH-59](+) is useful for analyzing their profile. APTDCI parameters, including angle of collection and incidence, gas flows and temperatures, were optimized for acylcarnitines. The experiments were performed drying 2 microL of an equimolar mixture of acylcarnitine standards on a glass slide. The specificity was evaluated by comparing product ion spectra and the precursor ion spectra of 85 m/z of acylcarnitines obtained by the APTDCI method and by electrospray ionization flow injection analysis (ESI-FIA). The method was also employed to analyze acylcarnitines extracted from a pathological dried blood spot and a control. The method enables analysis of biological samples and recognition of some acylcarnitines that are diagnostic markers of inherited metabolic diseases. The intrinsic high-throughput analysis of the ambient desorption ionization methods offers a new opportunity either for its potential application in clinical chemistry and for the expanded screening of some inborn errors of metabolism.

  2. Ion intensity and thermal proton transfer in ultraviolet matrix-assisted laser desorption/ionization.

    Science.gov (United States)

    Lu, I-Chung; Lee, Chuping; Chen, Hui-Yuan; Lin, Hou-Yu; Hung, Sheng-Wei; Dyakov, Yuri A; Hsu, Kuo-Tung; Liao, Chih-Yu; Lee, Yin-Yu; Tseng, Chien-Ming; Lee, Yuan-Tseh; Ni, Chi-Kung

    2014-04-17

    The ionization mechanism of ultraviolet matrix-assisted laser desorption/ionization (UV-MALDI) was investigated by measuring the total cation intensity (not including sodiated and potasiated ions) as a function of analyte concentration (arginine, histidine, and glycine) in a matrix of 2,4,6-trihydroxyacetophenone (THAP). The total ion intensity increased up to 55 times near the laser fluence threshold as the arginine concentration increased from 0% to 1%. The increases were small for histidine, and a minimal increase occurred for glycine. Time-resolved fluorescence intensity was employed to investigate how analytes affected the energy pooling of the matrix. No detectable energy pooling was observed for pure THAP and THAP/analyte mixtures. The results can be described by using a thermal proton transfer model, which suggested that thermally induced proton transfer is crucial in the primary ion generation in UV-MALDI.

  3. Climate change expands the spatial extent and duration of preferred thermal habitat for lake Superior fishes.

    Directory of Open Access Journals (Sweden)

    Timothy J Cline

    Full Text Available Climate change is expected to alter species distributions and habitat suitability across the globe. Understanding these shifting distributions is critical for adaptive resource management. The role of temperature in fish habitat and energetics is well established and can be used to evaluate climate change effects on habitat distributions and food web interactions. Lake Superior water temperatures are rising rapidly in response to climate change and this is likely influencing species distributions and interactions. We use a three-dimensional hydrodynamic model that captures temperature changes in Lake Superior over the last 3 decades to investigate shifts in habitat size and duration of preferred temperatures for four different fishes. We evaluated habitat changes in two native lake trout (Salvelinus namaycush ecotypes, siscowet and lean lake trout, Chinook salmon (Oncorhynchus tshawytscha, and walleye (Sander vitreus. Between 1979 and 2006, days with available preferred thermal habitat increased at a mean rate of 6, 7, and 5 days per decade for lean lake trout, Chinook salmon, and walleye, respectively. Siscowet lake trout lost 3 days per decade. Consequently, preferred habitat spatial extents increased at a rate of 579, 495 and 419 km(2 per year for the lean lake trout, Chinook salmon, and walleye while siscowet lost 161 km(2 per year during the modeled period. Habitat increases could lead to increased growth and production for three of the four fishes. Consequently, greater habitat overlap may intensify interguild competition and food web interactions. Loss of cold-water habitat for siscowet, having the coldest thermal preference, could forecast potential changes from continued warming. Additionally, continued warming may render more suitable conditions for some invasive species.

  4. Effect of Ionizing Beta Radiation on the Mechanical Properties of Poly(ethylene under Thermal Stress

    Directory of Open Access Journals (Sweden)

    Bednarik Martin

    2016-01-01

    Full Text Available It was found in this study, that ionizing beta radiation has a positive effect on the mechanical properties of poly(ethylene. In recent years, there have been increasing requirements for quality and cost effectiveness of manufactured products in all areas of industrial production. These requirements are best met with the polymeric materials, which have many advantages in comparison to traditional materials. The main advantages of polymer materials are especially in their ease of processability, availability, and price of the raw materials. Radiation crosslinking is one of the ways to give the conventional plastics mechanical, thermal, and chemical properties of expensive and highly resistant construction polymers. Several types of ionizing radiation are used for crosslinking of polymers. Each of them has special characteristics. Electron beta and photon gamma radiation are used the most frequently. The great advantage is that the crosslinking occurs after the manufacturing process at normal temperature and pressure. The main purpose of this paper has been to determine the effect of ionizing beta radiation on the tensile modulus, strength and elongation of low and high density polyethylene (LDPE and HDPE. These properties were examined in dependence on the dosage of the ionizing beta radiation (non-irradiated samples and those irradiated by dosage 99 kGy were compared and on the test temperature. Radiation cross-linking of LDPE and HDPE results in increased tensile strength and modulus, and decreased of elongation. The measured results indicate that ionizing beta radiation treatment is effective tool for improvement of mechanical properties of LDPE and HDPE under thermal stress.

  5. Thermal proton transfer reactions in ultraviolet matrix-assisted laser desorption/ionization.

    Science.gov (United States)

    Chu, Kuan Yu; Lee, Sheng; Tsai, Ming-Tsang; Lu, I-Chung; Dyakov, Yuri A; Lai, Yin Hung; Lee, Yuan-Tseh; Ni, Chi-Kung

    2014-03-01

    One of the reasons that thermally induced reactions are not considered a crucial mechanism in ultraviolet matrix-assisted laser desorption ionization (UV-MALDI) is the low ion-to-neutral ratios. Large ion-to-neutral ratios (10(-4)) have been used to justify the unimportance of thermally induced reactions in UV-MALDI. Recent experimental measurements have shown that the upper limit of the total ion-to-neutral ratio is approximately 10(-7) at a high laser fluence and less than 10(-7) at a low laser fluence. Therefore, reexamining the possible contributions of thermally induced reactions in MALDI may be worthwhile. In this study, the concept of polar fluid was employed to explain the generation of primary ions in MALDI. A simple model, namely thermal proton transfer, was used to estimate the ion-to-neutral ratios in MALDI. We demonstrated that the theoretical calculations of ion-to-neutral ratios exhibit the same trend and similar orders of magnitude compared with those of experimental measurements. Although thermal proton transfer may not generate all of the ions observed in MALDI, the calculations demonstrated that thermally induced reactions play a crucial role in UV-MALDI.

  6. Standard test method for uranium and plutonium concentrations and isotopic abundances by thermal ionization mass spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 This test method covers the determination of the concentration and isotopic composition of uranium and plutonium in solutions. The purified uranium or plutonium from samples ranging from nuclear materials to environmental or bioassay matrices is loaded onto a mass spectrometric filament. The isotopic ratio is determined by thermal ionization mass spectrometry, the concentration is determined by isotope dilution. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish safety and health practices and determine the applicability of regulatory limitations prior to use.

  7. Thin-layer chromatography and mass spectrometry coupled using proximal probe thermal desorption with electrospray or atmospheric pressure chemical ionization.

    Science.gov (United States)

    Ovchinnikova, Olga S; Van Berkel, Gary J

    2010-06-30

    An atmospheric pressure proximal probe thermal desorption sampling method coupled with secondary ionization by electrospray or atmospheric pressure chemical ionization was demonstrated for the mass spectrometric analysis of a diverse set of compounds (dyestuffs, pharmaceuticals, explosives and pesticides) separated on various high-performance thin-layer chromatography plates. Line scans along or through development lanes on the plates were carried out by moving the plate relative to a stationary heated probe positioned close to or just touching the stationary phase surface. Vapors of the compounds thermally desorbed from the surface were drawn into the ionization region of a combined electrospray ionization/atmospheric pressure chemical ionization source where they merged with reagent ions and/or charged droplets from a corona discharge or an electrospray emitter and were ionized. The ionized components were then drawn through the atmospheric pressure sampling orifice into the vacuum region of a triple quadrupole mass spectrometer and detected using full scan, single ion monitoring, or selected reaction monitoring mode. Studies of variable parameters and performance metrics including the proximal probe temperature, gas flow rate into the ionization region, surface scan speed, read-out resolution, detection limits, and surface type are discussed.

  8. Crosslinking of rigid PVC by ionizing radiation to improve its thermal properties

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Castaneda, C. [Centro de Investigacion en Quimica Aplicada, Blvd. Enrique Reyna 140, Saltillo Coahuila (Mexico); Benavides, R., E-mail: robertob@ciqa.m [Centro de Investigacion en Quimica Aplicada, Blvd. Enrique Reyna 140, Saltillo Coahuila (Mexico); Martinez-Pardo, M.E. [Instituto Nacional de Investigaciones Nucleares, Apartado postal 18-1027, Col. Escandon, 11801 Mexico, D.F. (Mexico); Uribe, R.M. [Kent State University, College of Technology and Program on Electron Beam Technology, P.O. Box 5190, Kent, OH 44242-0001 (United States); Carrasco-Abrego, H. [Instituto Nacional de Investigaciones Nucleares, Apartado postal 18-1027, Col. Escandon, 11801 Mexico, D.F. (Mexico); Martinez, G. [Centro de Investigacion en Quimica Aplicada, Blvd. Enrique Reyna 140, Saltillo Coahuila (Mexico)

    2010-03-15

    Rigid PVC formulations containing two different stabilizer systems (tin and Ca/Zn) and TMPTMA as a crosslinking agent were treated with ionizing radiation (gamma and electron beam) at different doses and irradiation atmospheres. The objective was to increase thermal and mechanical properties of this material. Polyene formation was followed through the yellowing index (YI), the extent of crosslinking by gel percentage, thermal resistance by Vicat temperature and the mechanical properties by DMA. Both formulations became colored with irradiation, especially with gamma as a result of a longer treatment time; the gel formation and the Vicat temperature were also higher for gamma treated samples, suggesting that values were enhanced by oxidation. However, DMA elastic modulus traces were almost similar for both treatments. The main difference observed for Ca/Zn samples compared with traditional tin samples was the lower ability of the former system in protecting the material against processing conditions.

  9. First-Principles Investigations on Thermal Conductivity and Average Ionization of CH Ablators Under Extreme Conditions

    Science.gov (United States)

    Hu, S. X.; Goncharov, V. N.; McCrory, R. L.; Skupsky, S.; Collins, L. A.; Kress, J. D.

    2015-11-01

    A plastic CH ablator (polystyrene) is often used for inertial confinement fusion (ICF) target designs. Upon intense laser or x-ray ablations, a CH ablator can be shocked to warm-dense-matter (WDM) conditions. Many-body coupling and quantum electron degeneracy are expected to play an essential role in determining the properties of such warm dense plasmas. Using ab initio methods of quantum molecular dynamics (QMD), we have performed investigations on the principal Hugoniot of a CH ablator, the first-principles equation-of-state table of CH, and its effect on ICF simulations. In this presentation, we focus on the thermal conductivity and average ionization of CH-ablators under a wide range of plasma temperatures and densities. The resulting thermal conductivity (κ) and average ionization () show large differences from the usual model predictions in the WDM regime. These results, being fitted with analytical functions of plasma density and temperature, have been incorporated into radiation -hydrodynamics codes. Their effects on the ICF implosion simulations will be presented. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number DE-NA0001944 and the Scientific Campaign 10 at LANL under Contract No. DE-AC52-06NA25396.

  10. Changes of Blood Flow Volume in the Superior Mesenteric Artery and Brachial Artery with Abdominal Thermal Stimulation

    Directory of Open Access Journals (Sweden)

    Shin Takayama

    2011-01-01

    Full Text Available In traditional Chinese medicine, moxibustion is a local thermal therapy that is used for several conditions. Quantifying the effects of moxibustion therapy has been difficult because the treatment temperature depends on the physician's experience, and the temperature distribution in the target area is not uniform. This prospective observational study aims to quantify the effect of local thermal stimulation to the abdomen. We developed a heat transfer control device (HTCD for local thermal stimulation. Twenty-four healthy subjects were enrolled and they underwent abdominal thermal stimulation to the para-umbilical region with the device for 20 min. Blood flow volume in the superior mesenteric artery (SMA and brachial artery (BA, the heart rate and the blood pressure were measured at rest, 15 min after starting thermal stimulation and 10, 20, 30 and 40 min after completing thermal stimulation. Blood flow parameters were measured by high-resolution ultrasound. In the SMA, blood flow volume was significantly increased during thermal stimulation (, as well as at 10 min ( and 20 min ( after stimulation. In the BA, blood flow volume decreased at 40 min after stimulation (. In conclusion we could quantify the effect of local thermal stimulation with an HTCD and high-resolution ultrasound. Thermal stimulation of the para-umbilical region increased blood flow in the SMA 20 min after stimulation in healthy subjects.

  11. GoAmazon 2014/15 Thermal Desorption Chemical Ionization Mass Spectrometer (TDCIMS) Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    Smith, JN [Univ. of California, Irvine, CA (United States)

    2016-04-01

    The Thermal Desorption Chemical Ionization Mass Spectrometer (TDCIMS) deployment to the U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility T3 site in Manacapuru, Brazil, was motivated by two main scientific objectives of the Green Ocean Amazon (GoAmazon) 2014/15 field campaign. 1) Study the interactions between anthropogenic and biogenic emissions by determining important molecular species in ambient nanoparticles. To address this, TDCIMS data will be combined with coincident measurements such as gas-phase sulfuric acid to determine the contribution of sulfuric acid condensation to nucleation and growth. We can then compare that result to TDCIMS-derived nanoparticle composition to determine the fraction of growth that can be attributed to the uptake of organic compounds. The molecular composition of sampled particles will also be used to attribute specific chemical species and mechanisms to growth, such as the condensation of low-volatility species or the oligomerization of α-dicarbonyl compounds. 2) Determine the source of new ambient nanoparticles in the Amazon. The hypothesis prior to measurements was that potassium salts formed from the evaporation of primary particles emitted by fungal spores can provide a unique and important pathway for new particle production in the Amazon basin. To explore this hypothesis, the TDCIMS recorded the mass spectra of sampled ambient particles using a protonated water cluster Chemical Ionization Mass Spectrometer (CIMS). Laboratory tests performed using potassium salts show that the TDCIMS can detect potassium with high sensitivity with this technique.

  12. Negative ion beam formation using thermal contact ionization type plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Fukuura, Yoshiyuki; Murakami, Kazutugu; Masuoka, Toshio; Katsumata, Itsuo [Osaka City Univ. (Japan). Faculty of Engineering

    1997-02-01

    The small ion sources utilizing thermal ionization have been already developed, and at present, in order to increase ion yield, that being developed to the cylindrical plasma prototype having the inner surface of a Re foil cylinder as the ionization surface, and stably functioning at 3,000 K has been developed, and by using this plasma source, the research on the formation of various ions has been carried out. At present, the research on the formation of Li negative ion beam is carried out. The separation of negative ions from electrons is performed with the locally limited magnetic field using a small iron core electromagnet placed behind the electrostatic accelerating lens system. So for, the formation of about 2 {mu}A at maximum of negative ions was confirmed. It was decided to identify the kinds of ions by time of flight (TOF) process, and the various improvements for this purpose were carried out. The experimental setup, the structure of the plasma source, the circuits for TOF measurement and so on are explained. The experimental results are reported. The problems are the possibility of the formation of alkali metals, the resolution of the time axis of the TOF system and so on. (K.I.)

  13. Separation Techniques for Uranium and Plutonium at Trace Levels for the Thermal Ionization Mass Spectrometric Determination

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Han, S. H.; Kim, J. G.; Park, Y. J.; Kim, W. H

    2005-12-15

    This report describes the state of the art and the progress of the chemical separation and purification techniques required for the thermal ionization mass spectrometric determination of uranium and plutonium in environmental samples at trace or ultratrace levels. Various techniques, such as precipitation, solvent extraction, extraction chromatography, and ion exchange chromatography, for separation of uranium and plutonium were evaluated. Sample preparation methods and dissolution techniques for environmental samples were also discussed. Especially, both extraction chromatographic and anion exchange chromatographic procedures for uranium and plutonium in environmental samples, such as soil, sediment, plant, seawater, urine, and bone ash were reviewed in detail in order to propose some suitable methods for the separation and purification of uranium and plutonium from the safeguards environmental or swipe samples. A survey of the IAEA strengthened safeguards system, the clean room facility of IAEA's NWAL(Network of Analytical Laboratories), and the analytical techniques for safeguards environmental samples was also discussed here.

  14. Thermal ionization mass spectrometry (TIMS) of actinides: Pushing the limits of accuracy and detection

    Energy Technology Data Exchange (ETDEWEB)

    Buerger, Stefan; Boulyga, Sergei; Cunningham, Alan; Klose, Dilani; Koepf, Andreas; Poths, Jane [Safeguards Analytical Laboratory, International Atomic Energy Agency, Vienna (Austria); Richter, Stephan [Institute for Reference Materials and Measurements, JRC-EU, Geel (Belgium)

    2010-07-01

    New method developments in multi-collector thermal ionization mass spectrometry (MC-TIMS) for actinide isotope ratio analysis to improve accuracy and limits of detection will be presented. With respect to limits of detection, results on improving work function using various carbon additives will be reviewed and presented as well as developments in cavity ion source (as compared to standard flat ribbon filament ion source) for femto- and attogram levels of uranium, plutonium, and americium. With respect to accuracy, results on isotope ratio measurements of isotopes of uranium (relative accuracy of 0.3% to 0.01%) are presented with an example being U-234-Th-230 age-dating (NBL CRM 112-A). In this context, the importance of traceability (to the S.I. units) and the use of (certified) reference materials are emphasized. The focus of this presentation is on applications to nuclear safeguards / forensics.

  15. Effect of ionizing radiation on the thermal oxidative stability of medical polymers

    Energy Technology Data Exchange (ETDEWEB)

    Woo, L.; Ling, M.T.K.; Ding, S.Y.; Westphal, S.P. [Baxter International, Round Lake, IL 60073 (United States)

    1998-12-21

    In the medical-device industry, most products need to be sterilized prior to use. Sterilization by ionizing radiation is fast becoming the preferred method on account of its effectiveness and economy. However, energetic secondary electrons released from the primary irradiation event can cause significant damage and degrade the polymer. We have undertaken a study on the thermal oxidative stability of several medical polymers as measured by the oxidative induction time (OIT) on radiation exposures. It was found that, in selected cases with polyolefins, active antioxidants can be completely consumed during the sterilization process, leaving the polymer unprotected for the required shelf life. In addition, comparison between {gamma}- and electron-beam irradiation sources revealed major differences on OIT reduction, primarily due to the dose rate effect. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  16. Absolute isotopic composition and atomic weight of neodymium using thermal ionization mass spectrometry.

    Science.gov (United States)

    Zhao, Motian; Zhou, Tao; Wang, Jun; Lu, Hai; Fang, Xiang; Guo, Chunhua; Li, Qiuli; Li, Chaofeng

    2005-01-01

    Synthetic mixtures prepared gravimetrically from highly enriched isotopes of neodymium in the form of oxides of well-defined purity were used to calibrate a thermal ionization mass spectrometer. A new error analysis was applied to calculate the final uncertainty of the atomic weight value. Measurements on natural neodymium samples yielded an absolute isotopic composition of 27.153(19) atomic percent (at.%) 142Nd, 12.173(18) at.% 143Nd, 23.798(12) at.% 144Nd, 8.293(7) at.% 145Nd, 17.189(17) at.% 146Nd, 5.756(8) at.% 148Nd, and 5.638(9) at.% 150Nd, and the atomic weight of neodymium as 144.2415(13), with uncertainties given on the basis of 95% confidence limits. No isotopic fractionation was found in terrestrial neodymium materials.

  17. Atomic Force Microscopy Thermally-Assisted Microsampling with Atmospheric Pressure Temperature Ramped Thermal Desorption/Ionization-Mass Spectrometry Analysis.

    Science.gov (United States)

    Hoffmann, William D; Kertesz, Vilmos; Srijanto, Bernadeta R; Van Berkel, Gary J

    2017-02-20

    The use of atomic force microscopy controlled nanothermal analysis probes for reproducible spatially resolved thermally assisted sampling of micrometer-sized areas (ca. 11 × 17 μm wide × 2.4 μm deep) from relatively low number-average molecular weight (Mn mass spectrometric analysis. The procedure and mechanism for material pickup, the sampling reproducibility and sampling size are discussed, and the oligomer distribution information available from slow temperature ramps versus ballistic temperature jumps is presented. For the Mn = 970 P2VP, the Mn and polydispersity index determined from the mass spectrometric data were in line with both the label values from the sample supplier and the value calculated from the simple infusion of a solution of polymer into the commercial atmospheric pressure chemical ionization source on this mass spectrometer. With a P2VP sample of higher Mn (Mn = 2070 and 2970), intact oligomers were still observed (as high as m/z 2793 corresponding to the 26-mer), but a significant abundance of thermolysis products were also observed. In addition, the capability for confident identification of the individual oligomers by slowly ramping the probe temperature and collecting data-dependent tandem mass spectra was also demonstrated. The material type limits to the current sampling and analysis approach as well as possible improvements in nanothermal analysis probe design to enable smaller area sampling and to enable controlled temperature ramps beyond the present upper limit of about 415 °C are also discussed.

  18. Climate Change Expands the Spatial Extent and Duration of Preferred Thermal Habitat for Lake Superior Fishes

    OpenAIRE

    Cline, Timothy J.; Bennington, Val; James F Kitchell

    2013-01-01

    Climate change is expected to alter species distributions and habitat suitability across the globe. Understanding these shifting distributions is critical for adaptive resource management. The role of temperature in fish habitat and energetics is well established and can be used to evaluate climate change effects on habitat distributions and food web interactions. Lake Superior water temperatures are rising rapidly in response to climate change and this is likely influencing species distribut...

  19. Renewable and superior thermal-resistant cellulose-based composite nonwoven as lithium-ion battery separator.

    Science.gov (United States)

    Zhang, Jianjun; Liu, Zhihong; Kong, Qingshan; Zhang, Chuanjian; Pang, Shuping; Yue, Liping; Wang, Xuejiang; Yao, Jianhua; Cui, Guanglei

    2013-01-01

    A renewable and superior thermal-resistant cellulose-based composite nonwoven was explored as lithium-ion battery separator via an electrospinning technique followed by a dip-coating process. It was demonstrated that such nanofibrous composite nonwoven possessed good electrolyte wettability, excellent heat tolerance, and high ionic conductivity. The cells using the composite separator displayed better rate capability and enhanced capacity retention, when compared to those of commercialized polypropylene separator under the same conditions. These fascinating characteristics would endow this renewable composite nonwoven a promising separator for high-power lithium-ion battery.

  20. Measurement of 26Al in Iron Meteorites by Thermal Ionization Mass Spectrometry

    Science.gov (United States)

    Langellier, C.; Birck, J. L.; Allegre, C. J.

    1992-07-01

    We report here the measurement of ^26Al by thermal ionization mass spectrometry in iron meteorites. Nuclides produced by the interaction of galactic cosmic rays with meteoritic bodies are widely used to reconstruct the parental history of meteorites and also to address the problem of constancy of cosmic rays in the past. In iron meteorites the half life of ^26Al is much shorter than the exposure age and saturation is reached. Its concentration is then directly related to the preatmospheric shielding of the analyzed sample. It can be also used together, with other short-lived nuclides, to calculate the terrestrial residence time for found meteorites. Natural contents of ^26Al in iron meteorites are very small (a few dpm per kg) and have been measured earlier by counting techniques and AMS. For thermal ionization the difficulty resides mostly in the measurement of the ^26Al/^27Al ratio. ^27Al may be contained in the sample and also is introduced by the chemical separation. ^27Al beams of 10^-11 A are readily obtained with a few ng of aluminium and are measured on a standard faraday cup. ^26Al was measured on a low background electron multiplier operated in the ion counter mode. ^27Al content was measured by isotope dilution using a ^26Al spike. The ^26Al ion beam can be interfered by traces of ^26Mg. Usually the ^26Mg background could be brought lower than 10^-9 relative to ^27Al. This is sufficient for the present experiment. No organic interference was present at the same level. The abundance sensitivity stemming from the ^27Al beam on mass 26 is 3 10^-9. Results: Samples sizes for this study range from 100 to 300 mg of iron. Ratios are measured with a precision of about 1% thereby leading to a final ^26Al content with an accuracy around 2%. Two meteorites were investigated so far: Grant and Canyon Diablo. Grant is one of the best documented meteorites with regard to spallation effects. The result on Grant is an agreement with literature AMS data (Graf et al., 1987

  1. Separation and Analysis of Boron Isotope in High Plant by Thermal Ionization Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Qingcai Xu

    2015-01-01

    Full Text Available Knowledge of boron and its isotope in plants is useful to better understand the transposition and translocation of boron within plant, the geochemical behavior in the interface between soil and plant, and the biogeochemical cycle of boron. It is critical to develop a useful method to separate boron from the plant for the geochemical application of boron and its isotope. A method was developed for the extraction of boron in plant sample, whose isotope was determined by thermal ionization mass spectrometry. The results indicated that this method of dry ashing coupled with two-step ion-exchange chromatography is powerful for the separation of boron in plant sample with large amounts of organic matters completely. The ratios of boron isotope composition in those plant tissue samples ranged from -19.45‰ to +28.13‰ (total range: 47.58‰ with a mean value of 2.61±11.76‰ SD. The stem and root isotopic compositions were lower than those in flower and leaf. The molecular mechanism of boron isotope may be responsible for the observed variation of boron isotopic composition and are considered as a useful tool for the better understanding of boron cycling process in the environment and for the signature of living systems.

  2. Atomic force microscope controlled topographical imaging and proximal probe thermal desorption/ionization mass spectrometry imaging.

    Science.gov (United States)

    Ovchinnikova, Olga S; Kjoller, Kevin; Hurst, Gregory B; Pelletier, Dale A; Van Berkel, Gary J

    2014-01-21

    This paper reports on the development of a hybrid atmospheric pressure atomic force microscopy/mass spectrometry imaging system utilizing nanothermal analysis probes for thermal desorption surface sampling with subsequent atmospheric pressure chemical ionization and mass analysis. The basic instrumental setup and the general operation of the system were discussed, and optimized performance metrics were presented. The ability to correlate topographic images of a surface with atomic force microscopy and a mass spectral chemical image of the same surface, utilizing the same probe without moving the sample from the system, was demonstrated. Co-registered mass spectral chemical images and atomic force microscopy topographical images were obtained from inked patterns on paper as well as from a living bacterial colony on an agar gel. Spatial resolution of the topography images based on pixel size (0.2 μm × 0.8 μm) was better than the resolution of the mass spectral images (2.5 μm × 2.0 μm), which were limited by current mass spectral data acquisition rate and system detection levels.

  3. Determination of Pu-238 Abundance in a Plutonium Standard by an Advanced Thermal Ionization Mass Spectrometric Technique

    Science.gov (United States)

    Mason, P.; Thomas, R.

    2006-12-01

    New developments in thermal ionization mass spectrometers allow for the determination of very small minor isotope ratios. The new hardware and software capabilities require attention to detail and accounting for additional sources of measurement uncertainty. The Pu-238 isotopic composition in New Brunswick Laboratory plutonium metal standard CRM 126-A was determined by thermal ionization mass spectrometry using combined Faraday cup and ion counting detection. A dynamic acquisition scheme was employed which provided for near real-time mass fractionation correction and ion counter/Faraday detector inter-calibration. Steps taken to minimize or eliminate isobaric U-238 interferences will be described, and an evaluation detailing contributions to the uncertainty, including SEM non-linearity, will be presented.

  4. Flexible Aerogel as a Superior Thermal Insulation for High Temperature Superconductor Cable Applications

    Science.gov (United States)

    White, S.; Demko, J.; Tomich, A.

    2010-04-01

    High temperature superconducting (HTS) cables are an advanced technology that can both strengthen and improve the national electrical distribution infrastructure. HTS cables require sufficient cooling to overcome inherent low temperature heat loading. Heat loads are minimized by the use of cryogenic envelopes or cryostats. Cryostats require improvement in efficiency, reliability, and cost reduction to meet the demanding needs of HTS conductors (1G and 2G wires). Aspen Aerogels has developed a compression resistant aerogel thermal insulation package to replace compression sensitive multi-layer insulation (MLI), the incumbent thermal insulation, in flexible cryostats for HTS cables. Oak Ridge National Laboratory tested a prototype aerogel package in a lab-scale pipe apparatus to measure the rate of heat invasion. The lab-scale pipe test results of the aerogel solution will be presented and directly compared to MLI. A compatibility assessment of the aerogel material with HTS system components will also be presented. The aerogel thermal insulation solution presented will meet the demanding needs of HTS cables.

  5. High Precision Thermal Ionization Mass Spectrometric Dating of Corals and Its Application to Paleo—Environmental Study

    Institute of Scientific and Technical Information of China (English)

    王兆荣; 张兆峰; 等

    2001-01-01

    Global change has become a hot spot in Quaternary geology,and high-precision,high-sensitivity dating is also an urgent problem which needs to be solved.This paper presents some achievements in U-servies dating of marine corals by thermal ionization mass spectrometry (TIMS) and its application to the study of paleo-environments.Recently,coral samples were determined for their ages on a MAT-262 mass spectrometer and satisfactory results have been obtained.

  6. High Precision Thermal Ionization Mass Spectrometric Dating of Corals and Its Application to Paleo-Environmental Study

    Institute of Scientific and Technical Information of China (English)

    王兆荣; 张兆峰; 彭子成; 马志邦

    2001-01-01

    Global change has become a hot spot in Quaternary geology, and high-precision,high-sensitivity dating is also an urgent problem which needs to be solved. This paper presents some achievements in U-series dating of marine corals by thermal ionization mass spectrometry (TIMS) and its application to the study of paleo-environments. Recently, coral samples were determined for their ages on a MAT-262 mass spectrometer and satisfactory results have been obtained.

  7. Thermal ionization induced metal-semiconductor transition and room temperature ferromagnetism in trivalent doped ZnO codoped with lithium

    Energy Technology Data Exchange (ETDEWEB)

    Sivagamasundari, A.; Chandrasekar, S.; Pugaze, R.; Kannan, R., E-mail: kannan@pec.edu [Department of Physics, Pondicherry Engineering College, Puducherry 605 014 (India); Rajagopan, S. [Department of Chemistry, Pondicherry Engineering College, Puducherry 605 014 (India)

    2014-03-07

    Thermal ionization induced metallic to semiconductor (MST) transition occurring at 460 K for Zn{sub 0.97}Al{sub 0.03}O, 463 K for Zn{sub 0.94}Al{sub 0.03}Li{sub 0.03}O, and 503 K for Zn{sub 0.91}Al{sub 0.03}Li{sub 0.03}Mn{sub 0.03}O has been found in the sol-gel synthesized (using hexamethylenetetramine), trivalent doped (Al, Mn) ZnO codoped with lithium. Increase in the thermally ionized carrier concentration due to Al doping is responsible for near band edge (NBE) peak shift causing Fermi level to move into conduction band making it metallic consistent with resistivity results. Free carrier (thermally activated) neutralization with ionized donor is responsible for semiconducting nature, which is supported from the free carrier screening produced energy shift in the NBE of photoluminescence peak. Furthermore, independently band gap shrinkage is also obtained from UV-Visible studies confirming localization induced MST. An anti-correlation is found between defect density (DLE) and room temperature ferromagnetism (RTFM) indicating intrinsic defects are not directly responsible for RTFM.

  8. Dendrimer-Linked Antifreeze Proteins Have Superior Activity and Thermal Recovery.

    Science.gov (United States)

    Stevens, Corey A; Drori, Ran; Zalis, Shiran; Braslavsky, Ido; Davies, Peter L

    2015-09-16

    By binding to ice, antifreeze proteins (AFPs) depress the freezing point of a solution and inhibit ice recrystallization if freezing does occur. Previous work showed that the activity of an AFP was incrementally increased by fusing it to another protein. Even larger increases in activity were achieved by doubling the number of ice-binding sites by dimerization. Here, we have combined the two strategies by linking multiple outward-facing AFPs to a dendrimer to significantly increase both the size of the molecule and the number of ice-binding sites. Using a heterobifunctional cross-linker, we attached between 6 and 11 type III AFPs to a second-generation polyamidoamine (G2-PAMAM) dendrimer with 16 reactive termini. This heterogeneous sample of dendrimer-linked type III constructs showed a greater than 4-fold increase in freezing point depression over that of monomeric type III AFP. This multimerized AFP was particularly effective at ice recrystallization inhibition activity, likely because it can simultaneously bind multiple ice surfaces. Additionally, attachment to the dendrimer has afforded the AFP superior recovery from heat denaturation. Linking AFPs together via polymers can generate novel reagents for controlling ice growth and recrystallization.

  9. Highly Porous, Rigid-Rod Polyamide Aerogels with Superior Mechanical Properties and Unusually High Thermal Conductivity.

    Science.gov (United States)

    Williams, Jarrod C; Nguyen, Baochau N; McCorkle, Linda; Scheiman, Daniel; Griffin, Justin S; Steiner, Stephen A; Meador, Mary Ann B

    2017-01-18

    We report here the fabrication of polyamide aerogels composed of poly-p-phenylene-terephthalamide, the same backbone chemistry as DuPont's Kevlar. The all-para-substituted polymers gel without the use of cross-linker and maintain their shape during processing-an improvement over the meta-substituted cross-linked polyamide aerogels reported previously. Solutions containing calcium chloride (CaCl2) and para-phenylenediamine (pPDA) in N-methylpyrrolidinone (NMP) at low temperature are reacted with terephthaloyl chloride (TPC). Polymerization proceeds over the course of 5 min resulting in gelation. Removal of the reaction solvent via solvent exchange followed by extraction with supercritical carbon dioxide provides aerogels with densities ranging from 0.1 to 0.3 g/cm(3), depending on the concentration of calcium chloride, the formulated number of repeat units, n, and the concentration of polymer in the reaction mixture. These variables were assessed in a statistical experimental study to understand their effects on the properties of the aerogels. Aerogels made using at least 30 wt % CaCl2 had the best strength when compared to aerogels of similar density. Furthermore, aerogels made using 30 wt % CaCl2 exhibited the lowest shrinkage when aged at elevated temperatures. Notably, whereas most aerogel materials are highly insulating (thermal conductivities of 10-30 mW/m K), the polyamide aerogels produced here exhibit remarkably high thermal conductivities (50-80 mW/(m K)) at the same densities as other inorganic and polymer aerogels. These high thermal conductivities are attributed to efficient phonon transport by the rigid-rod polymer backbone. In conjunction with their low cost, ease of fabrication with respect to other polymer aerogels, low densities, and high mass-normalized strength and stiffness properties, these aerogels are uniquely valuable for applications such as lightweighting in consumer electronics, automobiles, and aerospace where weight reduction is

  10. Superior thermal conductivity of transparent polymer nanocomposites with a crystallized alumina membrane

    Directory of Open Access Journals (Sweden)

    Md. Poostforush

    2014-04-01

    Full Text Available The properties of novel thermoconductive and optically transparent nanocomposites have been reported. The composites were prepared by the impregnation of thermoset resin into crystallized anodic aluminum oxide (AAO. Crystallized AAO synthesized by annealing amorphous AAO membrane at 1200°C. Although through-plane thermal conductivity of nanocomposites improved up to 1.13 W•m–1•K–1 (39 vol% alumina but their transparency was preserved (Tλ550 nm ~ 72%. Integrated annealed alumina phase, low refractive index mismatch between resin and alumina and formation of nano-optical fibers through the membrane resulted in such marvel combination. This report shows a great potential of these types of nanocomposites in ‘heat management’ of lightening devices.

  11. Polyetherimide/bucky gels nanocomposites with superior conductivity and thermal stability

    KAUST Repository

    Chen, Ye

    2013-08-14

    Polyetherimide (PEI) nanocomposites comprising bucky gels of industrial-grade multiwalled carbon nanotubes (MWCNTs) and ionic liquid (IL, 1-butyl-3-methyl imidazolium hexafluorophosphate ([BMIM][PF6])) were prepared. The processing framework for this nanocomposite is simple, reproducible, and easily scalable. The strong interaction between IL and MWCNTs caused the latter to uniformly disperse in the PEI matrix while IL flowed into the gaps between the nanotubes\\' walls. The nanocomposite exhibited an enhanced conductivity of 2.01 × 104 Ω·cm volume resistivity at room temperature; the value decreased dramatically by 12 orders of magnitude, compared to pristine PEI. The IL free ions and MWCNTs networks provided excellent channels for electron transfer. PEI/bucky gels nanocomposites also showed improved thermal stability and high tensile strength. Other than having antiwear properties, this material can have numerous applications in the aerospace and electronics industries. Moreover, our work presents a "green" method toward modified nanocomposites industrial production as IL is environmentally safe and is easily recyclable. © 2013 American Chemical Society.

  12. The Concerted Impact of Galaxies and QSOs on the Ionization and Thermal State of the Intergalactic Medium

    CERN Document Server

    Kakiichi, Koki; Ciardi, Benedetta; Meiksin, Avery; Compostella, Michele; Eide, Marius B; Zaroubi, Saleem

    2016-01-01

    We present a detailed analysis of the ionization and thermal structure of the intergalactic medium (IGM) around a high-redshift QSO using a large suite of cosmological, multi-frequency radiative transfer (RT) simulations, exploring the contribution from galaxies as well as the QSO, and the effect of X-rays and secondary ionization. We show that in high-z QSO environments both the central QSO and the surrounding galaxies concertedly control the reionization morphology of hydrogen and helium and have a non-linear impact on the thermal structure of the IGM. A QSO imprints a distinctive morphology on H II regions if its total ionizing photon budget exceeds that of the surrounding galaxies since the onset of hydrogen reionization; otherwise, the morphology shows little difference from that of H II regions produced only by galaxies. In addition, the spectral shape of the collective radiation field from galaxies and QSOs controls the thickness of the I-fronts. While a UV-obscured QSO can broaden the I-front, the con...

  13. Rapid identification of pesticides in human oral fluid for emergency management by thermal desorption electrospray ionization/mass spectrometry.

    Science.gov (United States)

    Lee, Chi-Wei; Su, Hung; Chen, Peng-Yu; Lin, Shiang-Jiun; Shiea, Jentaie; Shin, Shyi-Jang; Chen, Bai-Hsiun

    2016-02-01

    Self-poisoning with pesticides accounts for approximately one-third of all suicides worldwide. To expedite rescue in the emergency department, it is essential to develop a point-of-care analytical method for rapid identification of ingested pesticides. In this study, five of the most common pesticides ingested by self-poisoning patients in Taiwan were analyzed from oral fluid samples. Pesticide-oral fluid mixtures were applied on a cotton swab and then transferred into methanol. A metallic probe was used to sample the methanol solution for subsequent thermal desorption-electrospray ionization mass spectrometry analysis. Altogether, pesticide sampling, transfer, desorption, ionization, and detection took less than 1 min. The reproducibility of this method (n = 6) was shown in the observed low-relative standard deviation (four human subjects by thermal desorption-electrospray ionization mass spectrometry were between 1-10 ppb with relative standard deviation 10.7%. Moreover, in this study, linear responses of five pesticides in oral fluid with concentrations between 1 ppb-1 ppm (R2 between 0.9938 and 0.9988) were observed. As the whole analytical process is extremely short, this technique allows for early non-invasive point-of-care identification of pesticides in the oral fluid of self-poisoning patients in the emergency room, providing important toxicological information for decision-making during critical resuscitation.

  14. Improved sample utilization in thermal ionization mass spectrometry isotope ratio measurements: refined development of porous ion emitters for nuclear forensic applications

    Energy Technology Data Exchange (ETDEWEB)

    Baruzzini, Matthew Louis [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-08

    The precise and accurate determination of isotopic composition in nuclear forensic samples is vital for assessing origin, intended use and process history. Thermal ionization mass spectrometry (TIMS) is widely accepted as the gold standard for high performance isotopic measurements and has long served as the workhorse in the isotopic ratio determination of nuclear materials. Nuclear forensic and safeguard specialists have relied heavily on such methods for both routine and atypical e orts. Despite widespread use, TIMS methods for the assay of actinide systems continue to be hindered by poor ionization e ciency, often less than tenths of a percent; the majority of a sample is not measured. This represents a growing challenge in addressing nextgeneration nuclear detection needs by limiting the ability to analyze ultratrace quantities of high priority elements that could potentially provide critical nuclear forensic signatures. Porous ion emitter (PIE) thermal ion sources were developed in response to the growing need for new TIMS ion source strategies for improved ionization e ciency, PIEs have proven to be simple to implement, straightforward approach to boosting ion yield. This work serves to expand the use of PIE techniques for the analysis of trace quantities of plutonium and americium. PIEs exhibited superior plutonium and americium ion yields when compared to direct lament loading and the resin bead technique, one of the most e cient methods for actinide analysis, at similar mass loading levels. Initial attempts at altering PIE composition for the analysis of plutonium proved to enhance sample utilization even further. Preliminary investigations of the instrumental fractionation behavior of plutonium and uranium analyzed via PIE methods were conducted. Data collected during these initial trial indicate that PIEs fractionate in a consistent, reproducible manner; a necessity for high precision isotope ratio measurements. Ultimately, PIEs methods were applied for

  15. Ion-to-Neutral Ratios and Thermal Proton Transfer in Matrix-Assisted Laser Desorption/Ionization.

    Science.gov (United States)

    Lu, I-Chung; Chu, Kuan Yu; Lin, Chih-Yuan; Wu, Shang-Yun; Dyakov, Yuri A; Chen, Jien-Lian; Gray-Weale, Angus; Lee, Yuan-Tseh; Ni, Chi-Kung

    2015-07-01

    The ion-to-neutral ratios of four commonly used solid matrices, α-cyano-4-hydroxycinnamic acid (CHCA), 2,5-dihydroxybenzoic acid (2,5-DHB), sinapinic acid (SA), and ferulic acid (FA) in matrix-assisted laser desorption/ionization (MALDI) at 355 nm are reported. Ions are measured using a time-of-flight mass spectrometer combined with a time-sliced ion imaging detector. Neutrals are measured using a rotatable quadrupole mass spectrometer. The ion-to-neutral ratios of CHCA are three orders of magnitude larger than those of the other matrices at the same laser fluence. The ion-to-neutral ratios predicted using the thermal proton transfer model are similar to the experimental measurements, indicating that thermal proton transfer reactions play a major role in generating ions in ultraviolet-MALDI.

  16. Thermal Ionization Plasma Generation and Spectrum Test%热电离等离子体生成及光谱测试研究

    Institute of Scientific and Technical Information of China (English)

    钟孟春; 宋鹏; 毛保全

    2016-01-01

    本文针对热电离等离子体如何生成问题进行研究。以火药燃气产生的等离子体为研究对象,通过分析火药燃烧过程的四个阶段和相应的气体生成物,讨论了火药燃气生成热电离等离子体的过程,并对能够生成热电离等离子体的分子数在气体总分子数中所占的百分比进行了计算。最后建立了一套热电离等离子体试验系统,采用光谱测试法对热电离等离子体进行测试,获得电子温度、电子密度等参数。该研究为热电离等离子体的进一步的应用提供了一定的理论依据。%This paper studies the generation of thermal ionization plasma. Taking the plasma produced by gunpowder gas as the research object, through the analysis of the four stages of gunpowder combustion process and the corresponding gas products, this paper discusses the process of gunpowder gas generating thermal ionization plasma, and calculates the percentage of the number of molecules to be able to generate thermal ionization plasma in the total number of molecules in the gas. Finally a set of thermal ionization plasma test system is established, and the method of spectrum test is used to test the thermal ionization plasma to get parameters such as electron temperature, electron density. This study provides certain theoretical basis for the further application of thermal ionization plasma.

  17. The computation of hypersonic ionized flows in chemical and thermal nonequlibrium

    Science.gov (United States)

    Maccormack, Robert W.; Candler, Graham V.

    1988-01-01

    A numerical method to compute a two-dimensional hypersonic flowfield that is ionized and in thermochemical nonequilibrium has been developed. Such a flowfield is described by coupled time-dependent partial differential equations for the conservation of species mass, mass-average momentum, vibrational energy of each diatomic species, electron energy, and total mass-averaged energy. The steady-state solution to these fully coupled equations is obtained using an implicit Gauss-Seidel line relaxation technique. The computed electron densities in the flowfield compare well with experimental results.

  18. Extraction chromatographic methods in the sample preparation sequence for thermal ionization mass spectrometric analysis of plutonium isotopes.

    Science.gov (United States)

    Grate, Jay W; O'Hara, Matthew J; Farawila, Anne F; Douglas, Matthew; Haney, Morgan M; Petersen, Steven L; Maiti, Tapas C; Aardahl, Christopher L

    2011-12-01

    A sample preparation sequence for actinide isotopic analysis by thermal ionization mass spectrometry (TIMS) is described that includes column-based extraction chromatography as the first separation step, followed by anion-exchange column separations. The sequence is designed to include a wet ashing step after the extraction chromatography to prevent any leached extractant or oxalic acid eluent reagents from interfering with subsequent separations, source preparation, or TIMS ionization. TEVA resin and DGA resin materials, containing extractants that consist only of C, N, O, and H atoms, were investigated for isolation of plutonium. Radiotracer level studies confirmed expected high yields from column-based separation procedures. Femtogram-level studies were carried out with TIMS detection, using multiple monoisotopic spikes applied sequentially throughout the separation sequence. Pu recoveries were 87% and 86% for TEVA and DGA resin separations, respectively. The Pu recoveries from 400 μL anion-exchange column separation sequences were 89% and 93% for trial sequences incorporating TEVA and DGA resin. Thus, a prior extraction chromatography step in the sequence did not interfere with the subsequent anion-exchange separation when a simple wet ash step was carried out in between these column separations. The average measurement efficiency for Pu, encompassing the chemical separation recoveries and the TIMS ionization efficiency, was 2.73% ± 0.77% (2σ) for the DGA resin trials and 2.67% ± 0.54% for the TEVA resin trials, compared to 3.41% and 2.37% (average 2.89%) for two control trials. These compare with an average measurement efficiency of 2.78% ± 1.70%, n = 33 from process benchmark analyses using Pu spikes processed through a sequence of oxalate precipitation, wet ash, iron hydroxide precipitation, and anion-exchange column separations. We conclude that extraction chromatography can be a viable separation procedure as part of a multistep sequence for TIMS

  19. Direct Detection of Pharmaceuticals and Personal Care Products from Aqueous Samples with Thermally-Assisted Desorption Electrospray Ionization Mass Spectrometry

    Science.gov (United States)

    Campbell, Ian S.; Ton, Alain T.; Mulligan, Christopher C.

    2011-07-01

    An ambient mass spectrometric method based on desorption electrospray ionization (DESI) has been developed to allow rapid, direct analysis of contaminated water samples, and the technique was evaluated through analysis of a wide array of pharmaceutical and personal care product (PPCP) contaminants. Incorporating direct infusion of aqueous sample and thermal assistance into the source design has allowed low ppt detection limits for the target analytes in drinking water matrices. With this methodology, mass spectral information can be collected in less than 1 min, consuming ~100 μL of total sample. Quantitative ability was also demonstrated without the use of an internal standard, yielding decent linearity and reproducibility. Initial results suggest that this source configuration is resistant to carryover effects and robust towards multi-component samples. The rapid, continuous analysis afforded by this method offers advantages in terms of sample analysis time and throughput over traditional hyphenated mass spectrometric techniques.

  20. Rapid, high-purity chemical separation of molybdenum from iron meteorites for isotopic analysis by using thermal ionization mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Qi-Lu; Masuda, Akimasa (Tokyo Univ. (Japan). Dept. of Chemistry)

    1992-05-01

    A chemical procedure has been developed, which combines both solvent extraction and anion exchange, so that microgram amounts of Mo can be cleanly, rapidly and efficiently separated from gram amounts of iron meteorites. Particular attention was directed to the complete separation of Mo from Zr and Ru. The isotopic abundance ratios of Mo can subsequently be determined with high accuracy by using thermal ionization mass spectrometry. The experiments indicate that the behaviour of Mo during solvent extraction and anion exchange is considerably different from that reported previously. In particular, it was found that there is a very narrow range of HCl concentrations within which it is possible to separate Mo from Fe by solvent extraction. The reproducibility and recovery of the method were examined by using inductively coupled plasma atomic emission spectrometry. (Author).

  1. Quantification and isotope ratio determination of uranium in particles of environmental samples using isotope dilution thermal ionization mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong-Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Choi, Eun-Ju [Chungnam National University, Daejeon (Korea, Republic of)

    2015-10-15

    Highly accurate and precise quantitative and qualitative analysis of nuclear materials in environmental samples plays essential roles in monitoring undeclared nuclear activities of corresponding facilities. The former focuses on the quantification of uranium (U) and plutonium (Pu) contained in a whole sample, while the latter enables us to acquire the isotopic ratios, which serve as the crucial basis to trace the nuclear histories of a facility. However, the quantity of nuclear materials in a single-particle has not been acquired from the particle analysis, but has been estimated by the size of the particles. This report is to describe the method developed to determine the quantity and the isotopic ratios of uranium in a micro-particle simultaneously. Complete dissolution of particle-spike mixture by repeated addition of nitric acid on a rhenium filament was performed to ensure the homogeneity of the mixture. Thermal ionization mass spectrometry (TIMS) was utilized to measure the U isotope ratios of the mixture with high accuracy. The isotopic ratios of the uranium in the particle sample were determined by mathematical deconvolution of U isotopic ratios of the mixture. Verification using particles of a certified reference material showed that the newly developed method can be used to quantify and to determine the isotopic ratios of U in a particle simultaneously. The development of a method for simultaneous determination of the quantity and the isotope ratios of uranium contained in particles by isotope dilution thermal ionization mass spectrometry (ID-TIMS) was described. For homogeneity of the mixture of particles and spike, repeated dissolution using nitric acid for five times was performed.

  2. Toward realistic simulations of magneto-thermal winds from weakly-ionized protoplanetary disks

    CERN Document Server

    Gressel, Oliver

    2016-01-01

    Protoplanetary disks (PPDs) accrete onto their central T Tauri star via magnetic stresses. When the effect of ambipolar diffusion (AD) is included, and in the presence of a vertical magnetic field, the disk remains laminar between 1-5 au, and a magnetocentrifugal disk wind forms that provides an important mechanism for removing angular momentum. We present global MHD simulations of PPDs that include Ohmic resistivity and AD, where the time-dependent gas-phase electron and ion fractions are computed under FUV and X-ray ionization with a simplified recombination chemistry. To investigate whether the mass loading of the wind is potentially affected by the limited vertical extent of our existing simulations, we attempt to develop a model of a realistic disk atmosphere. To this end, by accounting for stellar irradiation and diffuse reprocessing of radiation, we aim at improving our models towards more realistic thermodynamic properties.

  3. Thermal desorption counter-flow introduction atmospheric pressure chemical ionization for direct mass spectrometry of ecstasy tablets.

    Science.gov (United States)

    Inoue, Hiroyuki; Hashimoto, Hiroaki; Watanabe, Susumu; Iwata, Yuko T; Kanamori, Tatsuyuki; Miyaguchi, Hajime; Tsujikawa, Kenji; Kuwayama, Kenji; Tachi, Noriyuki; Uetake, Naohito

    2009-09-01

    A novel approach to the analysis of ecstasy tablets by direct mass spectrometry coupled with thermal desorption (TD) and counter-flow introduction atmospheric pressure chemical ionization (CFI-APCI) is described. Analytes were thermally desorbed with a metal block heater and introduced to a CFI-APCI source with ambient air by a diaphragm pump. Water in the air was sufficient to act as the reactive reagent responsible for the generation of ions in the positive corona discharge. TD-CFI-APCI required neither a nebulizing gas nor solvent flow and the accompanying laborious optimizations. Ions generated were sent in the direction opposite to the air flow by an electric field and introduced into an ion trap mass spectrometer. The major ions corresponding to the protonated molecules ([M + H](+)) were observed with several fragment ions in full scan mass spectrometry (MS) mode. Collision-induced dissociation of protonated molecules gave characteristic product-ion mass spectra and provided identification of the analytes within 5 s. The method required neither sample pretreatment nor a chromatographic separation step. The effectiveness of the combination of TD and CFI-APCI was demonstrated by application to the direct mass spectrometric analysis of ecstasy tablets and legal pharmaceutical products.

  4. Optimization Techniques for Improving the Precision of Isotopic Analysis by Thermal Ionization Mass Spectrometry

    Science.gov (United States)

    Wang, G. Q.; Xu, J. F.; Wu-Yang, S. Q.

    2016-12-01

    Operation of instruments and preparation of samples are also significant factors that can affect the precision of TIMS analyses, in addition to instrument hardware. We have reviewed the isotopic data of several standard materials at our TIMS lab for 5 years. It is suggested that several optimization techniques should be used in order to obtain high-precision isotopic ratio data: (1) It is important to choose a suitable filament material for isotopic measurements. We have established that W filament is likely the most efficient for ionizing Sr when selecting from W, Re, and Ta; meanwhile, Re filament can produce a higher intensity for Nd isotopes than W and Ta filament can. It is concluded that the best TIMS signals are obtained for Sr using W signal-filaments and for Nd using Re double-filaments. (2) The preparation of the activator plays a key role in the analysis of some isotopic ratios. This study indicates that choosing a suitable activator can greatly elevate the precision of 206Pb/204Pb ratios during Pb isotopic measurements. We have suggested a new scheme to make an activator by using a mixture of 10% Si-gel + 7.5% H3PO3 + 82.5% H2O (weight %). (3) It is necessary to re-set the cup configuration to avoid cup degradation when operating for a long period of time (a year or more). We propose a new cup configuration to avoid this disadvantage during Sr isotopic analyses. (4) The contamination of 187Re and 185Re after using Re-filament could be eliminated by cleaning the ion source and baking the source housing.

  5. Total microcystins analysis in water using laser diode thermal desorption-atmospheric pressure chemical ionization-tandem mass spectrometry.

    Science.gov (United States)

    Roy-Lachapelle, Audrey; Fayad, Paul B; Sinotte, Marc; Deblois, Christian; Sauvé, Sébastien

    2014-04-11

    A new approach for the analysis of the cyanobacterial microcystins (MCs) in environmental water matrices has been developed. It offers a cost efficient alternative method for the fast quantification of total MCs using mass spectrometry. This approach permits the quantification of total MCs concentrations without requiring any derivatization or the use of a suite of MCs standards. The oxidation product 2-methyl-3-methoxy-4-phenylbutyric acid (MMPB) was formed through a Lemieux oxidation and represented the total concentration of free and bound MCs in water samples. MMPB was analyzed using laser diode thermal desorption-atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD-APCI-MS/MS). LDTD is a robust and reliable sample introduction method with ultra-fast analysis time (0.999). Limits of detection and quantification were 0.2 and 0.9 μg L(-1), respectively. These values are comparable with the WHO (World Health Organization) guideline of 1 μg L(-1) for total microcystin-LR congener in drinking water. Accuracy and interday/intraday variation coefficients were below 15%. Matrix effect was determined with a recovery of 91%, showing no significant signal suppression. This work demonstrates the use of the LDTD-APCI-MS/MS interface for the screening, detection and quantification of total MCs in complex environmental matrices.

  6. Investigation of uranium isotopic signatures in real-life particles from a nuclear facility by thermal ionization mass spectrometry.

    Science.gov (United States)

    Kraiem, Monia; Richter, Stephan; Kühn, Heinz; Stefaniak, Elzbieta A; Kerckhove, Giovani; Truyens, Jan; Aregbe, Yetunde

    2011-04-15

    An improved method was recently developed for the isotopic analysis of single-reference uranium oxide particles for nuclear safeguards. This method is a combination of analytical tools including in situ SEM micromanipulation, filament carburization and multiple ion counting (MIC) detection, which is found to improve sensitivity for thermal ionization mass spectrometry (TIMS) isotope ratio analysis. The question was raised whether this method could be applied for the detection of nuclear signatures in real-life particles with unknown isotopic composition. Therefore, environmental dust was collected in different locations within a nuclear facility. The screening of the samples to find the uranium particles of interest was performed using a scanning electron microscope (SEM) equipped with an energy-dispersive X-ray (EDX) detector. The comparison of the measurement results to reference data evaluated by international safeguards authorities was of key importance for data interpretation. For the majority of investigated particles, detection of uranium isotopic signatures provided information on current and past nuclear feed operations that compared well with facility declarations.

  7. High-precision thermal ionization mass spectrometry dating of young volcanic rocks by using U-series method

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    A high precision thermal ionization mass spectrometric (HP-TIMS) technique is used to determine 238U,234U,232Th,230Th concentrations and their ratios in whole rocks and minerals separated from Quaternary Maanshan,Dayingshan and Heikongshan volcanic rocks of Tengchong volcanic field,Yunnan Province,China.The 238U-230Th isochrons are given,yielding four age values (227± 20) ka (D-1,Dayingshan),(79.6± 5.5) ka (D-7,Dayingshan),(21.9± 3.0) ka (h-1,Heikongshan),and (7.5± 1.0) ka (M-1,Maanshan).The result is not only consistent with but also preciser than those measured by the K-Ar method and the alpha spectrometry U-series method,indicating that the HP-TIMS method is reliable and has high precision.Besides,a procedure of HP-TIMS analysis of young volcanic rocks in China is set up preliminarily.

  8. Superior Thermally Stable and Nonflammable Porous Polybenzimidazole Membrane with High Wettability for High-Power Lithium-Ion Batteries.

    Science.gov (United States)

    Li, Dan; Shi, Dingqin; Xia, Yonggao; Qiao, Lin; Li, Xianfeng; Zhang, Huamin

    2017-02-28

    Separators with high security, reliability, and rate capacity are in urgent need for the advancement of high power lithium ion batteries. The currently used porous polyolefin membranes are critically hindered by their low thermal stability and poor electrolyte wettability, which further lead to low rate capacity. Here we present a novel promising porous polybenzimidazole (PBI) membrane with super high thermal stability and electrolyte wettability. The rigid structure and functional groups in the PBI chain enable membranes to be stable at temperature as high as 400 °C, and the unique flame resistance of PBI could ensure the high security of a battery as well. In particular, the prepared membrane owns 328% electrolyte uptake, which is more than two times higher than commercial Celgard 2325 separator. The unique combination of high thermal stability, high flame resistance and super high electrolyte wettability enable the PBI porous membranes to be highly promising for high power lithium battery.

  9. Expanded graphite embedded with aluminum nanoparticles as superior thermal conductivity anodes for high-performance lithium-ion batteries.

    Science.gov (United States)

    Zhao, Tingkai; She, Shengfei; Ji, Xianglin; Guo, Xinai; Jin, Wenbo; Zhu, Ruoxing; Dang, Alei; Li, Hao; Li, Tiehu; Wei, Bingqing

    2016-09-27

    The development of high capacity and long-life lithium-ion batteries is a long-term pursuing and under a close scrutiny. Most of the researches have been focused on exploring electrode materials and structures with high store capability of lithium ions and at the same time with a good electrical conductivity. Thermal conductivity of an electrode material will also have significant impacts on boosting battery capacity and prolonging battery lifetime, which is, however, underestimated. Here, we present the development of an expanded graphite embedded with Al metal nanoparticles (EG-MNPs-Al) synthesized by an oxidation-expansion process. The synthesized EG-MNPs-Al material exhibited a typical hierarchical structure with embedded Al metal nanoparticles into the interspaces of expanded graphite. The parallel thermal conductivity was up to 11.6 W·m(-1)·K(-1) with a bulk density of 453 kg·m(-3) at room temperature, a 150% improvement compared to expanded graphite (4.6 W·m(-1)·K(-1)) owing to the existence of Al metal nanoparticles. The first reversible capacity of EG-MNPs-Al as anode material for lithium ion battery was 480 mAh·g(-1) at a current density of 100 mA·g(-1), and retained 84% capacity after 300 cycles. The improved cycling stability and system security of lithium ion batteries is attributed to the excellent thermal conductivity of the EG-MNPs-Al anodes.

  10. Expanded graphite embedded with aluminum nanoparticles as superior thermal conductivity anodes for high-performance lithium-ion batteries

    Science.gov (United States)

    Zhao, Tingkai; She, Shengfei; Ji, Xianglin; Guo, Xinai; Jin, Wenbo; Zhu, Ruoxing; Dang, Alei; Li, Hao; Li, Tiehu; Wei, Bingqing

    2016-09-01

    The development of high capacity and long-life lithium-ion batteries is a long-term pursuing and under a close scrutiny. Most of the researches have been focused on exploring electrode materials and structures with high store capability of lithium ions and at the same time with a good electrical conductivity. Thermal conductivity of an electrode material will also have significant impacts on boosting battery capacity and prolonging battery lifetime, which is, however, underestimated. Here, we present the development of an expanded graphite embedded with Al metal nanoparticles (EG-MNPs-Al) synthesized by an oxidation-expansion process. The synthesized EG-MNPs-Al material exhibited a typical hierarchical structure with embedded Al metal nanoparticles into the interspaces of expanded graphite. The parallel thermal conductivity was up to 11.6 W·m-1·K-1 with a bulk density of 453 kg·m-3 at room temperature, a 150% improvement compared to expanded graphite (4.6 W·m-1·K-1) owing to the existence of Al metal nanoparticles. The first reversible capacity of EG-MNPs-Al as anode material for lithium ion battery was 480 mAh·g-1 at a current density of 100 mA·g-1, and retained 84% capacity after 300 cycles. The improved cycling stability and system security of lithium ion batteries is attributed to the excellent thermal conductivity of the EG-MNPs-Al anodes.

  11. Expanded graphite embedded with aluminum nanoparticles as superior thermal conductivity anodes for high-performance lithium-ion batteries

    Science.gov (United States)

    Zhao, Tingkai; She, Shengfei; Ji, Xianglin; Guo, Xinai; Jin, Wenbo; Zhu, Ruoxing; Dang, Alei; Li, Hao; Li, Tiehu; Wei, Bingqing

    2016-01-01

    The development of high capacity and long-life lithium-ion batteries is a long-term pursuing and under a close scrutiny. Most of the researches have been focused on exploring electrode materials and structures with high store capability of lithium ions and at the same time with a good electrical conductivity. Thermal conductivity of an electrode material will also have significant impacts on boosting battery capacity and prolonging battery lifetime, which is, however, underestimated. Here, we present the development of an expanded graphite embedded with Al metal nanoparticles (EG-MNPs-Al) synthesized by an oxidation-expansion process. The synthesized EG-MNPs-Al material exhibited a typical hierarchical structure with embedded Al metal nanoparticles into the interspaces of expanded graphite. The parallel thermal conductivity was up to 11.6 W·m−1·K−1 with a bulk density of 453 kg·m−3 at room temperature, a 150% improvement compared to expanded graphite (4.6 W·m−1·K−1) owing to the existence of Al metal nanoparticles. The first reversible capacity of EG-MNPs-Al as anode material for lithium ion battery was 480 mAh·g−1 at a current density of 100 mA·g−1, and retained 84% capacity after 300 cycles. The improved cycling stability and system security of lithium ion batteries is attributed to the excellent thermal conductivity of the EG-MNPs-Al anodes. PMID:27671848

  12. Highly porous ZnS microspheres for superior photoactivity after Au and Pt deposition and thermal treatment

    Energy Technology Data Exchange (ETDEWEB)

    Singla, Shilpa; Pal, Bonamali, E-mail: bpal@thapar.edu

    2013-11-15

    Graphical abstract: Highly porous ZnS microsphere of size 2–5 μm having large surface area ca. 173.14 m{sup 2} g{sup −1} exhibits superior photocatalytic activity for the oxidation of 4-nitrophenol under UV light irradiation. The rate of photooxidation has been significantly improved by Au and Pt deposition and after sintering, respectively, due to rapid electron acceptance by metal from photoexcited ZnS and growth of crystalline ZnS phase. - Highlights: • Photoactive ZnS microsphere of size 2–5 μm was prepared by hydrothermal route. • Highly porous cubic spherical ZnS crystals possess a large surface area, 173 m{sup 2} g{sup −1}. • 1 wt% Au and Pt photodeposition highly quenched the photoluminescence at 437 nm. • Sintering and metal loading notably improve the photooxidation rate of 4-nitrophenol. • Pt co-catalyst always exhibits superior photoactivity of ZnS microsphere than Au. - Abstract: This work highlights the enhanced photocatalytic activity of porous ZnS microspheres after Au and Pt deposition and heat treatment at 500 °C for 2 h. Microporous ZnS particles of size 2–5 μm with large surface area 173.14 m{sup 2} g{sup −1} and pore volume 0.0212 cm{sup 3} g{sup −1} were prepared by refluxing under an alkaline medium. Photoluminescence of ZnS at 437 nm attributed to sulfur or zinc vacancies were quenched to 30% and 49%, respectively, after 1 wt% Au and Pt loading. SEM images revealed that each ZnS microparticle consist of several smaller ZnS spheres of size 2.13 nm as calculated by Scherrer's equation. The rate of photooxidation of 4-nitrophenol (10 μM) under UV (125 W Hg arc–10.4 mW/cm{sup 2}) irradiation has been significantly improved by Au and Pt deposition followed by sintering due to better electron capturing capacity of deposited metals and growth of crystalline ZnS phase with less surface defects.

  13. Determination of metformin in mouse, rat, dog and human plasma samples by laser diode thermal desorption/atmospheric pressure chemical ionization tandem mass spectrometry.

    Science.gov (United States)

    Swales, John G; Gallagher, Richard; Peter, Raimund M

    2010-11-02

    A simple, rapid and robust high-throughput assay for the quantitative analysis of metformin in plasma from different species using laser diode thermal desorption interfaced with atmospheric chemical pressure ionization tandem mass spectrometry (LDTD-APCI-MSMS) was developed for use in a pharmaceutical discovery environment. In order to minimize sample preparation a generic protein precipitation method was used to extract metformin from the plasma. Laser diode thermal desorption is a relatively new sample introduction method, the optimization of the instrumental parameters are presented. The method was successfully applied to spiked mouse, rat, dog and human plasma samples and was subsequently used to determine the oral pharmacokinetics of metformin after dosing to male rats in order to support drug discovery projects. The deviations for intra-assay accuracy and precision across the four species were less than 30% at all calibration and quality control levels.

  14. Identification of alkylated phosphates by gas chromatography-mass spectrometric investigations with different ionization principles of a thermally aged commercial lithium ion battery electrolyte.

    Science.gov (United States)

    Weber, Waldemar; Kraft, Vadim; Grützke, Martin; Wagner, Ralf; Winter, Martin; Nowak, Sascha

    2015-05-15

    The thermal aging process of a commercial LiPF6 based lithium ion battery electrolyte has been investigated in view of the formation of volatile phosphorus-containing degradation products. Aging products were analyzed by GC-MS. Structure determination of the products was performed by support of chemical ionization MS in positive and negative modes. A fraction of the discovered compounds belongs to the group of fluorophosphates (phosphorofluoridates) which are in suspect of potential toxicity. This is well known for relative derivatives, e.g. diisopropyl fluorophosphate. Another fraction of the identified compounds belongs to the group of trialkyl phosphates. These compounds may provide a positive impact on the thermal and electrochemical performance of Li-based batteries as repeatedly described in the literature.

  15. Effect of neutral collision and radiative heat-loss function on self-gravitational instability of viscous thermally conducting partially-ionized plasma

    Directory of Open Access Journals (Sweden)

    Sachin Kaothekar

    2012-12-01

    Full Text Available The problem of thermal instability and gravitational instability is investigated for a partially ionized self-gravitating plasma which has connection in astrophysical condensations. We use normal mode analysis method in this problem. The general dispersion relation is derived using linearized perturbation equations of the problem. Effects of collisions with neutrals, radiative heat-loss function, viscosity, thermal conductivity and magnetic field strength, on the instability of the system are discussed. The conditions of instability are derived for a temperature-dependent and density-dependent heat-loss function with thermal conductivity. Numerical calculations have been performed to discuss the effect of various physical parameters on the growth rate of the gravitational instability. The temperature-dependent heat-loss function, thermal conductivity, viscosity, magnetic field and neutral collision have stabilizing effect, while density-dependent heat-loss function has a destabilizing effect on the growth rate of the gravitational instability. With the help of Routh-Hurwitz's criterion, the stability of the system is discussed.

  16. Submerged arc furnace process superior to the Waelz process in reducing PCDD/F emission during thermal treatment of electric arc furnace dust.

    Science.gov (United States)

    Xu, Fu-Qian; Huang, Shao-Bin; Liao, Wei-Tung; Wang, Lin-Chi; Chang, Yu-Cheng; Chang-Chien, Guo-Ping

    2014-01-01

    Besides the Waelz process, the submerged arc furnace (SAF) process has also been extensively used to retain metals from ashes and scraps in the metallurgical industry. However, very little is known about the formation and depletion of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) from this thermal process. In this study, an electric arc furnace (EAF) dust treatment plant adopting the SAF process was investigated and compared to the plant adopting the Waelz process. The predominant contributor of PCDD/F I-TEQ input was the EAF dusts, accounting for 98.4% of the total. The PCDD/F contents in the generated fly ashes of the SAF were extremely low, as almost all the organic compounds for PCDD/F formation were decomposed by the high operating temperatures (1500-1700 °C) of the SAF. Therefore, the PCDD/F emission factor of the SAF process (46.9 μg I-TEQ/tonne-EAF dust) was significantly lower than that of the Waelz process (840-1120 μg I-TEQ/tonne-EAF dust). Its PCDD/F output/input ratios (0.23 and 0.50 based on mass and toxicity) were also lower than those of the Waelz process plant (0.62 and 1.19). Therefore, the SAF process is superior to the Waelz process in reducing the potential of PCDD/F formation.

  17. Diclofenac in municipal wastewater treatment plant: quantification using laser diode thermal desorption--atmospheric pressure chemical ionization--tandem mass spectrometry approach in comparison with an established liquid chromatography-electrospray ionization-tandem mass spectrometry method.

    Science.gov (United States)

    Lonappan, Linson; Pulicharla, Rama; Rouissi, Tarek; Brar, Satinder K; Verma, Mausam; Surampalli, Rao Y; Valero, José R

    2016-02-12

    Diclofenac (DCF), a prevalent non-steroidal anti-inflammatory drug (NSAID) is often detected in wastewater and surface water. Analysis of the pharmaceuticals in complex matrices is often laden with challenges. In this study a reliable, rapid and sensitive method based on laser diode thermal desorption/atmospheric pressure chemical ionization (LDTD/APCI) coupled with tandem mass spectrometry (MS/MS) has been developed for the quantification of DCF in wastewater and wastewater sludge. An established conventional LC-ESI-MS/MS (liquid chromatography-electrospray ionization-tandem mass spectrometry) method was compared with LDTD-APCI-MS/MS approach. The newly developed LDTD-APCI-MS/MS method reduced the analysis time to 12s in lieu of 12 min for LC-ESI-MS/MS method. The method detection limits for LDTD-APCI-MS/MS method were found to be 270 ng L(-1) (LOD) and 1000 ng L(-1) (LOQ). Furthermore, two extraction procedures, ultrasonic assisted extraction (USE) and accelerated solvent extraction (ASE) for the extraction of DCF from wastewater sludge were compared and ASE with 95.6 ± 7% recovery was effective over USE with 86 ± 4% recovery. The fate and partitioning of DCF in wastewater (WW) and wastewater sludge (WWS) in wastewater treatment plant was also monitored at various stages of treatment in Quebec Urban community wastewater treatment plant. DCF exhibited affinity towards WW than WWS with a presence about 60% of DCF in WW in contrary with theoretical prediction (LogKow=4.51).

  18. Combined Atomic Force Microscope-Based Topographical Imaging and Nanometer Scale Resolved Proximal Probe Thermal Desorption/Electrospray Ionization-Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ovchinnikova, Olga S [ORNL; Nikiforov, Maxim [ORNL; Bradshaw, James A [ORNL; Jesse, Stephen [ORNL; Van Berkel, Gary J [ORNL

    2011-01-01

    Nanometer scale proximal probe thermal desorption/electrospray ionization mass spectrometry (TD/ESI-MS) was demonstrated for molecular surface sampling of caffeine from a thin film using a 30 nm diameter nano-thermal analysis (nano-TA) probe tip in an atomic force microscope (AFM) coupled via a vapor transfer line and ESI interface to a MS detection platform. Using a probe temperature of 350 C and a spot sampling time of 30 s, conical desorption craters 250 nm in diameter and 100 nm deep were created as shown through subsequent topographical imaging of the surface within the same system. Automated sampling of a 5 x 2 array of spots, with 2 m spacing between spots, and real time selective detection of the desorbed caffeine using tandem mass spectrometry was also demonstrated. Estimated from the crater volume (~2x106 nm3), only about 10 amol (2 fg) of caffeine was liberated from each thermal desorption crater in the thin film. These results illustrate a relatively simple experimental setup and means to acquire in automated fashion sub-micrometer scale spatial sampling resolution and mass spectral detection of materials amenable to TD. The ability to achieve MS-based chemical imaging with 250 nm scale spatial resolution with this system is anticipated.

  19. Thermal dissociation atmospheric chemical ionization ion trap mass spectrometry with a miniature source for selective trace detection of dimethoate in fruit juices.

    Science.gov (United States)

    Ouyang, Yongzhong; Zhang, Xinglei; Han, Jing; Guo, Xiali; Zhu, Zhiqiang; Chen, Huanwen; Luo, Liping

    2013-01-21

    A miniature thermal dissociation atmospheric chemical ionization (TDCI) source, coupled with LTQ-MS, has been developed for rapid trace detection of pesticide residues such as dimethoate in highly viscous fruit juice samples. Instead of toxic organic solvents and the high electric field used in the conventional ionizations, an ionic liquid, a "green solvent", was employed to directly generate reagent ions in the TDCI process, followed by the proton or charge transfer with the analytes prior to the LTQ instrument for mass analysis. Trace amounts of dimethoate in fresh orange juices have been quantitatively detected, without any sample pretreatment or aid of high-pressure gas. A low limit of detection (LOD = 8.76 × 10(-11) g mL(-1)), acceptable relative standard deviation (RSD = 3.1-10.0%), and reasonable recoveries (91.2-102.8%) were achieved with this method for direct detection of dimethoate in highly viscous orange juice samples. The average analysis time for each single sample was less than 30 seconds. These experimental results showed that the miniature TDCI developed here is a powerful tool for the fast trace detection of pesticide residues in complex viscous fruit juices, with the advantage of high sensitivity, high speed, and high-throughput, ease of operation, and so on. Because of no chemical contamination and high voltage damage to the analytes and the environment, the technique has promising applications for online quality monitoring in the area of food safety.

  20. Direct isotope ratio analysis of individual uranium-plutonium mixed particles with various U/Pu ratios by thermal ionization mass spectrometry.

    Science.gov (United States)

    Suzuki, Daisuke; Esaka, Fumitaka; Miyamoto, Yutaka; Magara, Masaaki

    2015-02-01

    Uranium and plutonium isotope ratios in individual uranium-plutonium (U-Pu) mixed particles with various U/Pu atomic ratios were analyzed without prior chemical separation by thermal ionization mass spectrometry (TIMS). Prior to measurement, micron-sized particles with U/Pu ratios of 1, 5, 10, 18, and 70 were produced from uranium and plutonium certified reference materials. In the TIMS analysis, the peaks of americium, plutonium, and uranium ion signals were successfully separated by continuously increasing the evaporation filament current. Consequently, the uranium and plutonium isotope ratios, except the (238)Pu/(239)Pu ratio, were successfully determined for the particles at all U/Pu ratios. This indicates that TIMS direct analysis allows for the measurement of individual U-Pu mixed particles without prior chemical separation.

  1. Method for ultra-trace cesium isotope ratio measurements from environmental samples using thermal ionization mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Snow, Mathew S. [Washington State Univ., Pullman, WA (United States). Dept. of Chemistry; Idaho National Lab. (INL), Idaho Falls, ID (United States); Snyder, Darin C. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Mann, Nick R. [Idaho National Lab. (INL), Idaho Falls, ID (United States); White, Byron M. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-05-01

    135Cs/137Cs isotope ratios can provide the age, origin and history of environmental Cs contamination. Relatively high precision 135Cs/137Cs isotope ratio measurements from samples containing femtogram quantities of 137Cs are needed to accurately track contamination resuspension and redistribution following environmental 137Cs releases; however, mass spectrometric analyses of environmental samples are limited by the large quantities of ionization inhibitors and isobaric interferences which are present at relatively high concentrations in the environment. We report a new approach for Cs purification from environmental samples. An initial ammonium molybdophosphate-polyacrylonitrile (AMP-PAN) column provides a robust method for extracting Cs under a wide variety of sample matrices and mass loads. Cation exchange separations using a second AMP-PAN column result in more than two orders of magnitude greater Cs/Rb separation factors than commercially available strong cation exchangers. Coupling an AMP-PAN cation exchanging step to a microcation column (AG50W resin) enables consistent 2-4% (2σ) measurement errors for samples containing 3-6,000 fg 137Cs, representing the highest precision 135Cs/137Cs ratio measurements currently reported for soil samples at the femtogram level.

  2. Ceramide lipids in alive and thermally stressed mussels: an investigation by hydrophilic interaction liquid chromatography-electrospray ionization Fourier transform mass spectrometry.

    Science.gov (United States)

    Facchini, Laura; Losito, Ilario; Cataldi, Tommaso R I; Palmisano, Francesco

    2016-09-01

    Hydrophilic interaction liquid chromatography coupled to electrospray ionization-Fourier transform mass spectrometry was employed to study ceramide lipids occurring in mussels of sp. Mytilus galloprovincialis. Lipid extracts from alive mussels and mussels deliberately subjected to specific thermal treatments were analyzed. In particular, single and tandem MS measurements were performed on a hybrid quadrupole-Orbitrap mass spectrometer and then complemented by MS(n) analyses (n = 2, 3) achieved by a linear ion trap mass spectrometer. This approach enabled the characterization of 66 ceramide lipids, encompassing ceramide phosphoethanolamines (CPE), ceramide aminoethylphosphonates (CAEP) and N-monomethylated CAEP. The sphingoid and acyl chains of each ceramide lipid could be distinctly recognized in terms of numbers of carbon atoms and C=C bonds, and indications on the possible location of the latter on the sphingoid chain could be often inferred from fragmentation patterns. The occurrence of several species hydroxylated on the α carbon of the acyl chain was also discovered. On the other hand, the sphingoid chain of ceramide lipids was never found to be involved in oxidation processes, unless forced exposure of the mussel lipid extracts to atmospheric oxygen was performed. CPE(d19:3/16:0) and its hydroxylated form, CPE(d19:3/2-OH-16:0), were found to be the prevailing species among CPE, whereas CAEP(d18:2/16:0), CAEP(d19:3/16:0) and CAEP(d19:3/2-OH-16:0) were the most abundant CAEP. Finally, ceramide lipids showed a remarkably higher stability, compared with glycerophospholipids, in mussels subjected to different thermal treatments. This finding opens interesting perspectives on the role of ceramide-based lipids in the adaptation of aquatic organisms to thermal stresses. Copyright © 2016 John Wiley & Sons, Ltd.

  3. Quick Maintenance for High Voltage Equipment with the New Not Toxic Boron Nitride Powder (BN100) Superior Thermal Conductive and Lightweight Filler

    Science.gov (United States)

    2005-07-13

    used for the either mechanical and thermal test campaign is the EQM of a battery discharge regulator (BDR) module used in a Main Bus Regulator Unit...shown in its time sequence: Figure 2-6 Acc.#1 Acc.#2 3 - THERMAL TEST ON THE BDR BREADBOARD The test campaign is aimed at demonstrating...on the thermal test campaign The results resumed in Table 3-1 show a wide difference in terms of thermal dissipation in favour of the case with

  4. Improvement in Thermal-Ionization Mass Spectrometry (TIMS) using Total Flash Evaporation (TFE) method for lanthanides isotope ratio measurements in transmutation targets

    Energy Technology Data Exchange (ETDEWEB)

    Mialle, S.; Gourgiotis, A.; Aubert, M.; Stadelmann, G.; Gautier, C.; Isnard, H. [Commissariat a l' Energie Atomique, CEA Saclay, DEN/DPC/SECR/LANIE, 91191 Gif sur Yvette (France); Chartier, F. [Commissariat a l' Energie Atomique, CEA Saclay, DEN/DPC, 91191 Gif sur Yvette (France)

    2011-07-01

    The experiments involved in the PHENIX french nuclear reactor to obtain precise and accurate data on the total capture cross sections of the heavy isotopes and fission products require isotopic ratios measurements with uncertainty of a few per mil. These accurate isotopic ratio measurements are performed with mass spectrometer equipped with multi-collector system. The major difficulty for the analyses of these actinides and fission products is the low quantity of the initial powder enclosed in steel container (3 to 5 mg) and the very low quantities of products formed (several {mu}g) after irradiation. Specific analytical developments are performed by Thermal Ionization Mass Spectrometry (TIMS) to be able to analyse several nanograms of elements with this technique. A specific method of acquisition named Total Flash Evaporation was adapted in this study in the case of lanthanide measurements for quantity deposited on the filament in the order of 2 ng and applied on irradiated fuel. To validate the analytical approach and discuss about the accuracy of the data, the isotopic ratios obtained by TIMS are compared with other mass spectrometric techniques such as Multiple-Collector Inductively Coupled Plasma Mass Spectrometer (MC-ICPMS). (authors)

  5. Evaluation of lead isotope compositions of NIST NBS 981 measured by thermal ionization mass spectrometer and multiple-collector inductively coupled plasma mass spectrometer

    Directory of Open Access Journals (Sweden)

    Honglin Yuan

    2016-09-01

    Full Text Available Because Pb isotopes can be used for tracing, they are widely used in many disciplines. The detection and analysis of Pb isotopes of bulk samples are usually conducted using thermal ionization mass spectrometer (TIMS and multiple-collector inductively coupled plasma mass spectrometer (MC-ICP-MS, both of which need external reference materials with known isotopic compositions to correct for the mass discrimination effect produced during analysis. NIST NBS 981 is the most widely used reference material for Pb isotope analysis; however, the isotopic compositions reported by various analytical laboratories, especially those using TIMS, vary from each other. In this study, we statistically evaluated 229 reported TIMS analysis values collected by GeoReM in the last 30 years, 176 reported MC-ICP-MS analysis values, and 938 MC-ICP-MS analysis results from our laboratory in the last five years. After careful investigation, only 40 TIMS results were found to have double or triple spikes. The ratios of the overall weighted averages, 206Pb/204Pb, 207Pb/204Pb, and 208Pb/204Pb, obtained from 40 spiked TIMS reports and 1114 MC-ICP-MS results of NIST NBS 981 isotopes were 16.9406 ± 0.0003 (2s, 15.4957 ± 0.0002 (2s, and 36.7184 ± 0.0007 (2s, respectively.

  6. Standard test method for determination of uranium or plutonium isotopic composition or concentration by the total evaporation method using a thermal ionization mass spectrometer

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This method describes the determination of the isotopic composition and/or the concentration of uranium and plutonium as nitrate solutions by the thermal ionization mass spectrometric (TIMS) total evaporation method. Purified uranium or plutonium nitrate solutions are loaded onto a degassed metal filament and placed in the mass spectrometer. Under computer control, ion currents are generated by heating of the filament(s). The ion beams are continually measured until the sample is exhausted. The measured ion currents are integrated over the course of the run, and normalized to a reference isotope ion current to yield isotopic ratios. 1.2 In principle, the total evaporation method should yield isotopic ratios that do not require mass bias correction. In practice, some samples may require this bias correction. When compared to the conventional TIMS method, the total evaporation method is approximately two times faster, improves precision from two to four fold, and utilizes smaller sample sizes. 1.3 The tot...

  7. Effective elimination of organic matter interference in boron isotopic analysis by thermal ionization mass spectrometry of coral/foraminifera: micro-sublimation technology combined with ion exchange.

    Science.gov (United States)

    He, Maoyong; Xiao, Yingkai; Ma, Yunqi; Jin, Zhangdong; Xiao, Jun

    2011-03-30

    In order to better estimate the effectiveness of micro-sublimation technology on the elimination of organic matter interference during boron isotopic analysis, a series of improved experiments was carried out using simple apparatus. Recovery rates after micro-sublimation were measured for boric acid solutions with different B contents or different B/organic matter ratios. The improved micro-sublimation procedure combined with ion-exchange technology was then used to test natural samples (coral and foraminifera) for the separation of boron. Our results show that the time taken for 100% recovery of different amounts of B differed and that the proportions of B/organic matter within the natural organic matter have little effect on the relationship between the recovery rates of B and the micro-sublimation times. The experiments further confirm that the organic matter does indeed have an effect on boron isotope analyses by positive thermal ionization mass spectrometry and that the use of micro-sublimation can effectively remove interferences from the organic matter during boron isotopic analysis.

  8. Carbamazepine in municipal wastewater and wastewater sludge: ultrafast quantification by laser diode thermal desorption-atmospheric pressure chemical ionization coupled with tandem mass spectrometry.

    Science.gov (United States)

    Mohapatra, D P; Brar, S K; Tyagi, R D; Picard, P; Surampalli, R Y

    2012-09-15

    In this study, the distribution of the anti-epileptic drug carbamazepine (CBZ) in wastewater (WW) and aqueous and solid phases of wastewater sludge (WWS) was carried out. A rapid and reliable method enabling high-throughput sample analysis for quicker data generation, detection, and monitoring of CBZ in WW and WWS was developed and validated. The ultrafast method (15s per sample) is based on the laser diode thermal desorption-atmospheric pressure chemical ionization (LDTD-APCI) coupled to tandem mass spectrometry (MS/MS). The optimization of instrumental parameters and method application for environmental analysis are presented. The performance of the novel method was evaluated by estimation of extraction recovery, linearity, precision and detection limit. The method detection limits was 12 ng L(-1) in WW and 3.4 ng g(-1) in WWS. The intra- and inter-day precisions were 8% and 11% in WW and 6% and 9% in WWS, respectively. Furthermore, three extraction methods, ultrasonic extraction (USE), microwave-assisted extraction (MAE) and accelerated solvent extraction (ASE) with three different solvent condition such as methanol, acetone and acetonitrile:ethyle acetate (5:1, v/v) were compared on the basis of procedural blank and method recovery. Overall, ASE showed the best extraction efficiency with methanol as compared to USE and MAE. Furthermore, the quantification of CBZ in WW and WWS samples showed the presence of contaminant in all stages of the treatment plant.

  9. Stable Chlorine Isotopes and Elemental Chlorine by Thermal Ionization Mass Spectrometry and Ion Chromatography; Martian Meteorites, Carbonaceous Chondrites and Standard Rocks

    Science.gov (United States)

    Nakamura, N.; Nyquist, L. E.; Reese, Y.; Shih, C.-Y.; Fujitani, T.; Okano, O.

    2011-01-01

    Recently significantly large mass fractionation of stable chlorine isotopes has been reported for terrestrial and lunar samples [1,2]. In addition, in view of possible early solar system processes [3] and also potential perchlorate-related fluid/microbial activities on the Martian surface [4,5], a large chlorine isotopic fractionation might be expected for some types of planetary materials. Due to analytical difficulties of isotopic and elemental analyses, however, current chlorine analyses for planetary materials are controversial among different laboratories, particularly between IRMS (gas source mass spectrometry) and TIMS (Thermal Ionization Mass Spectrometry) groups [i.e. 1,6,7] for isotopic analyses, as well as between those doing pyrohydrolysis and other groups [i.e. 6,8]. Additional careful investigations of Cl isotope and elemental abundances are required to confirm real chlorine isotope and elemental variations for planetary materials. We have developed a TIMS technique combined with HF-leaching/ion chromatography at NASA JSC that is applicable to analysis of small amounts of meteoritic and planetary materials. We present here results for several standard rocks and meteorites, including Martian meteorites.

  10. Thermal Ionization Mass Spectrometry (TIMS)-U-Series Ages of Corals from the South China Sea and Holocene High Sea Level

    Institute of Scientific and Technical Information of China (English)

    彭子成; 何学贤; 罗晓忠; 贺剑峰; 刘桂建; 聂宝符

    2003-01-01

    Coral samples collected from the waters off the Leizhou Peninsula, the Hainan Island and the Yongxing Island of the Xisha Islands were analyzed by thermal ionization mass spectrometry (TIMS) and multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS)for their U-Th systematics. Their uranium contents are mostly lower than 3μg/g, and the δ 234U (T) values are within the range of 150 + 5. X-ray diffraction analysis showed that the corals are all composed of aragonite. This demonstrates that the corals determined have maintained a close system for 7000 years and their skeletons bear much information about the primitive tropical marine environment. The highly precise age sequence of the corals determined has revealed that there occurred three phases of high sea level in the South China Sea waters, which are dated at 6799 -6307 a B.P. , 4472 -4285 a B.P. and 1279 - 1012 a B. P. , respectively. The three phases lasted 492 a, 187 a and 267 a, respectively. These three phases of high sea level are corresponding to the warm environments that had appeared in China during the Megathermal Period and the Medieval Warm Period in the past ten thousand years.

  11. Ab initio investigation of structure, stability, thermal behavior, bonding, and infrared spectra of ionized water cluster (H2O)6+

    Science.gov (United States)

    Liu, Lei; Hu, Cui-E.; Tang, Mei; Chen, Xiang-Rong; Cai, Ling-Cang

    2016-10-01

    The low-lying isomers of cationic water cluster (H2O)6+ have been globally explored by using particle swarm optimization algorithm in conjunction with quantum chemical calculations. Compared with previous results, our searching method covers a wide range of structural isomers of (H2O)6+ and therefore turns out to be more effective. With these local minima, geometry optimization and vibrational analysis are performed for the most interesting clusters at second-order Møller-Plesset (MP2)/aug-cc-pVDZ level, and their energies are further refined at MP2/aug-cc-pVTZ and coupled-cluster theory with single, double, and perturbative triple excitations/aug-cc-pVDZ level. The interaction energies using the complete basis set limits at MP2 level are also reported. The relationships between their structure arrangement and their energies are discussed. Based on the results of thermal simulation, structural change from a four-numbered ring to a tree-like structure occurs at T ≈ 45 K, and the relative population of six lowest-free-energy isomers is found to exceed 4% at some point within the studied temperature range. Studies reveal that, among these six isomers, two new-found isomers constitute 10% of isomer population at 180 K, and the experimental spectra can be better explained with inclusions of the two isomers. The molecular orbitals for six representative cationic water clusters are also studied. Through topological and reduced density gradient analysis, we investigated the structural characteristics and the bonding strengths of these water cluster radical cations.

  12. Design and construction of models of solar thermal facilities in the ''Centro integrado de FP superior de energias renovables de Imarcoain''(Navarra); Maquetas de instalaciones solares termicas para la formacion profesional de grado superior en el centro integrado de formacion profesional superior de energias renovables

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, M. A.; Orus, L. M.; Yerro, C.; Aguado, H.; Cambra, T.; Oroz, J.

    2004-07-01

    This article shows how we have approached the solar energy installations in the ''Centro integrado de FP superior de energias renovables de Imarcoain''(Navarra) with the design and construction of models which allow us to teach in this type of installations at different levels. (Author)

  13. Analysis of trimethoprim, lincomycin, sulfadoxin and tylosin in swine manure using laser diode thermal desorption-atmospheric pressure chemical ionization-tandem mass spectrometry.

    Science.gov (United States)

    Solliec, Morgan; Massé, Daniel; Sauvé, Sébastien

    2014-10-01

    A new extraction method coupled to a high throughput sample analysis technique was developed for the determination of four veterinary antibiotics. The analytes belong to different groups of antibiotics such as chemotherapeutics, sulfonamides, lincosamides and macrolides. Trimethoprim (TMP), sulfadoxin (SFX), lincomycin (LCM) and tylosin (TYL) were extracted from lyophilized manure using a sonication extraction. McIlvaine buffer and methanol (MeOH) were used as extraction buffers, followed by cation-exchange solid phase extraction (SPE) for clean-up. Analysis was performed by laser diode thermal desorption-atmospheric pressure chemical-ionization (LDTD-APCI) tandem mass spectrometry (MS/MS) with selected reaction monitoring (SRM) detection. The LDTD is a high throughput sample introduction method that reduces total analysis time to less than 15s per sample, compared to minutes when using traditional liquid chromatography (LC). Various SPE parameters were optimized after sample extraction: the stationary phase, the extraction solvent composition, the quantity of sample extracted and sample pH. LDTD parameters were also optimized: solvent deposition, carrier gas, laser power and corona discharge. The method limit of detection (MLD) ranged from 2.5 to 8.3 µg kg(-1) while the method limit of quantification (MLQ) ranged from 8.3 to 28µgkg(-1). Calibration curves in the manure matrix showed good linearity (R(2)≥ 0.996) for all analytes and the interday and intraday coefficients of variation were below 14%. Recoveries of analytes from manure ranged from 53% to 69%. The method was successfully applied to real manure samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Ambient aging of rhenium filaments used in thermal ionization mass spectrometry: Growth of oxo-rhenium crystallites and anti-aging strategies

    Directory of Open Access Journals (Sweden)

    Joseph M. Mannion

    2017-01-01

    Full Text Available Degassing is a common preparation technique for rhenium filaments used for thermal ionization mass spectrometric analysis of actinides, including plutonium. Although optimization studies regarding degassing conditions have been reported, little work has been done to characterize filament aging after degassing. In this study, the effects of filament aging after degassing were explored to determine a “shelf-life” for degassed rhenium filaments, and methods to limit filament aging were investigated. Zone-refined rhenium filaments were degassed by resistance heating under high vacuum before exposure to ambient atmosphere for up to 2 months. After degassing the nucleation and preferential growth of oxo-rhenium crystallites on the surface of polycrystalline rhenium filaments was observed by atomic force microscopy and scanning electron microscopy (SEM. Compositional analysis of the crystallites was conducted using SEM-Raman spectroscopy and SEM energy dispersive X-ray spectroscopy, and grain orientation at the metal surface was investigated by electron back-scatter diffraction mapping. Spectra collected by SEM-Raman suggest crystallites are composed primarily of perrhenic acid. The relative extent of growth and crystallite morphology were found to be grain dependent and affected by the dissolution of carbon into filaments during annealing (often referred to as carbonization or carburization. Crystallites were observed to nucleate in region specific modes and grow over time through transfer of material from the surface. Factors most likely to affect the rates of crystallite growth include rhenium substrate properties such as grain size, orientation, levels of dissolved carbon, and relative abundance of defect sites; as well as environmental factors such as length of exposure to oxygen and relative humidity. Thin (∼180 nm hydrophobic films of poly(vinylbenzyl chloride were found to slow the growth of oxo-rhenium crystallites on the filament

  15. The Radio Light Curve of the Gamma-Ray Nova in V407 CYG: Thermal Emission from the Ionized Symbiotic Envelope, Devoured from Within by the Nova Blast

    Science.gov (United States)

    Chomiuk, Laura; Krauss, Miriam I.; Rupen, Michael P.; Nelson, Thomas; Roy, Nirupam; Sokoloski, Jennifer L.; Mukai, Koji; Munari, Ulisse; Mioduszewski, Amy; Weston, Jeninfer; O'Brien, Tim J.; Eyres, Steward P. S.; Bode, Michael F.

    2012-01-01

    We present multi-frequency radio observations of the 2010 nova event in the symbiotic binary V407 Cygni, obtained with the Karl G. Jansky Very Large Array (VLA) and spanning 1.45 GHz and 17.770 days following discovery. This nova.the first ever detected in gamma rays.shows a radio light curve dominated by the wind of the Mira giant companion, rather than the nova ejecta themselves. The radio luminosity grewas the wind became increasingly ionized by the nova outburst, and faded as the wind was violently heated from within by the nova shock. This study marks the first time that this physical mechanism has been shown to dominate the radio light curve of an astrophysical transient. We do not observe a thermal signature from the nova ejecta or synchrotron emission from the shock, due to the fact that these components were hidden behind the absorbing screen of the Mira wind. We estimate a mass-loss rate for the Mira wind of .Mw approximately equals 10(exp -6) Solar mass yr(exp -1). We also present the only radio detection of V407 Cyg before the 2010 nova, gleaned from unpublished 1993 archival VLA data, which shows that the radio luminosity of the Mira wind varies by a factor of 20 even in quiescence. Although V407 Cyg likely hosts a massive accreting white dwarf, making it a candidate progenitor system for a Type Ia supernova, the dense and radially continuous circumbinary material surrounding V407 Cyg is inconsistent with observational constraints on the environments of most Type Ia supernovae.

  16. Ionization in collisions between metastable hydrogen atoms

    Science.gov (United States)

    Bohr, Alex; Blickle, Andrew; Paolini, Stephen; Ohlinger, Luke; Forrey, Robert

    2012-06-01

    Associative and Penning ionization cross sections are calculated for collisions between metastable hydrogen 2s atoms at thermal energies. Cross sections for deuterium 2s collisions are also reported. The associative ionization cross sections behave as E-1 for collision energy E, in agreement with an existing experiment. The Penning ionization cross sections dominate for all energies and are found to follow the E-2/3 behavior that was predicted in previous work for the total ionization cross section. The magnitudes of our theoretical associative ionization cross sections for H(2s)+H(2s) collisions are between two and four times larger than the experimental data.

  17. A novel aerosol mass spectrometric approach - Analysis of the organic molecular signature of PM by coupling of thermal EC/OC-carbon analysis to photo-ionization mass spectrometry

    Science.gov (United States)

    Zimmermann, R.; Grabowski, J.; Streibel, T.; Sklorz, M.; Chow, J.

    2012-12-01

    Carbonaceous material in airborne particulate matter (PM) is of increasing interest e.g. due to its adverse health effects and its potential influence on the climate. Its analytical assessment on a molecular level is still very challenging. Hence, analysis of carbonaceous fractions for many studies is often solely carried out by determining sum parameters such as the overall content of organic carbon (OC) and elemental carbon (EC) as well as the total carbon content, TC (sum of OC and EC). The used thermal procedure, however, allows getting additional interesting information: By defining different thermal OC fractions (i.e. temperature steps) also information on the refractory properties of the carbonaceous material is obtained. In this context it is particularly interesting to investigate the release and formation behaviors of the molecular species responsible for the different OC and EC fractions. Thus after initial promising results of pre-studies [1,2] in the current work an EC/OC carbon analyzer (Model DRI 2000) and a homebuilt photo-ionization time-of-flight mass spectrometer (PI-TOFMS) were hyphenated and applied to investigate individual organic compounds especially from the different OC fractions. The carbon analyzer enables the stepwise heating of PM loaded filter samples and provides the sum values of the "carbon" release ("Improve protocol" [2]: OC1 - 120 °C, OC2 - 250°C, OC3 - 450°C OC4 - 550°C). With the on-line coupled PI-TOFMS evolved organic compounds, as released during the thermal program, are detectable in real time. This is possible by MS with soft photo ionization methods (SPI - single photon ionization and REMPI - resonance-enhanced multi photon ionization). Soft ionization suppresses fragmentation upon the ionization step and generates molecular signatures in the MS. The EC/OC-analyzer-PI-TOFMS instrument was applied to several types of PM samples, such as ambient aerosol, emission samples (gasoline/diesel car, wood combustion) or

  18. 单光子/光电子在线质谱实时分析聚氯乙烯热分解/燃烧产物%Real-Time Analysis of Polyvinyl Chloride Thermal Decomposition/Combustion Products with Single Photon Ionization/Photoelectron Ionization Online Mass Spectrometer

    Institute of Scientific and Technical Information of China (English)

    陈文东; 侯可勇; 陈平; 李芳龙; 赵无垛; 崔华鹏; 花磊; 谢园园; 李海洋

    2013-01-01

    With the features of a broad range of ionizable compounds, reduced fragments and simple mass spectrum, a homemade magnetic field enhanced photoelectron ionization (MEPEI) source combined with single photon ionization ( SPI) for time-of-flight mass spectrometer was built and applied to analyze thermal decomposition/combustion products of polyvinyi chloride (PVC). The combined ion source can be switched very fast between SPI mode and SPI-MEPEI mode for detecting different targeted compounds, and only adjusting the voltage of the electrode in the ionization region to trigger the switch. Among the PVC thermal decomposition/combustion products, HC1 and CO2 ,which ionization energies ( 12. 74 eV, 13. 77 eV respectively) were higher than the energy of photon (10. 60 eV) , were ionized by MEPEI, while alkenes, dichloroethylene, benzene and its homologs, monochlorobenzene, styrene, indane, naphthalene and its homologs were ionized by SPI and MEPEI simultaneously. Spectra of interested products as a function of temperatures indicated that products are formed via two main mechanisms; (1) dechlorination and intramolecular cyclization can lead to the formation of HC1, benzene and naphthalene at 250-370℃ ; (2) intermolecular crosslinking leads to the formation of alky] aromatics such as toluene and xylene/ethylbenzene at 380-510℃. The experimental results show that the combined ion source of SPI/ SPI-MEPEI for TOF-MS has broad application prospects in the online analysis field.%实验室研制了低能光电子磁场增强电离(MEPEI)和单光子电离(SPI)复合电离源,该电离源具有电离化合物范围宽、碎片离子少、质谱图简单等优点,结合飞行时间质谱(TOF-MS)实现了聚氯乙烯(PVC)热分解/燃烧产物的在线分析.针对不同的目标化合物,MEPEI/SPI复合电离源通过调节电离区电场强度,可以快速在SPI和SPI-MEPEI之间切换.PVC热分解/燃烧产物中电离能大于光子能量(10.60 eV)的HCl和CO2(12.74 eV、13

  19. Single photon ionization mass spectrometry with a novel electron-pumped excimer lamp for detection of trace compounds from thermal processes

    Energy Technology Data Exchange (ETDEWEB)

    Muehlberger, F. [GSF - Forschungszentrum fuer Umwelt und Gesundheit Neuherberg GmbH, Oberschleissheim (Germany). Inst. fuer Oekologische Chemie; Wieser, J. [TuiLaser AG, Germering (Germany); Ulrich, A. [Technische Univ. Muenchen, Garching (Germany). E12 - Lehrstuhl fuer Experimentalphysik; Zimmermann, R. [Augsburg Univ. (Germany). Analytische Chemie

    2004-09-15

    A combination of soft and selective photo-ionization methods, like the single photon ionization (SPI) using vacuum ultraviolet (VUV) light with mass spectrometry (MS), provides powerful analytical instrumentation for real-time on-line-monitoring of trace substances in complex process gases. New compact and robust, mobile SPI-MS instruments have been developed for on-line analysis of trace compounds (ppb concentrations). It is based on a novel VUV-lamp technology for efficient SPI ionization. With the VUV-lamp technology the development of rugged photoionization mass spectrometer systems seems feasible. These instruments can be used for continuous on-line monitoring of trace compounds, such as monochlorobenzene (MCB). Chlorobenzene, known as a surrogate for the emissions of dibenzo-p-dioxins (PCDD) and dibenzofurans (PCDF), was used to predict the emitted toxicity of PCDD/F (I-TEQ). Controlling such trace compounds is therefore an effective way to reduce toxic compounds in flue gases. A short description of the new SPI-MS is given. The combination of the new VUV-light source with a quadropole-MS is described briefly, and first results are presented.

  20. Thermal desorption-multiphoton ionization time-of-flight mass spectrometry of individual aerosol particles: a simplified approach for online single-particle analysis of polycyclic aromatic hydrocarbons and their derivatives.

    Science.gov (United States)

    Bente, Matthias; Sklorz, Martin; Streibel, Thorsten; Zimmermann, Ralf

    2009-04-01

    Online single-particle (SP) laser mass spectrometry (MS) is an important tool for fundamental and applied aerosol research. Usually laser desorption/ionization (LDI) is applied for ablation and ionization of atoms and molecular fragments from the nanometer- or micrometer-sized air-borne particles and time-of-flight analysers (TOFMS) are used for mass-selective detection of mainly inorganic analytes. The detection of molecular organic compounds is solely possible under very special experimental conditions and extremely dependent on the particle matrix and thus limited to special applications. Very recently it was shown that by implementation of a two-step laser desorption (LD) resonance-enhanced multiphoton ionization (REMPI) postionization approach the single-particulate molecular signature of polycyclic aromatic hydrocarbons (PAH) and their derivatives can be recorded (LD-REMPI-SP-TOFMS). By this, particles from different sources could be differentiated via the patterns of specific molecular source tracers such as retene for soft wood combustion or larger PAH as indicator for gasoline car emissions. One drawback of the LD-REMPI-SP-TOFMS method in particular for field applications is, however, the necessity of operation and adjustment of two lasers. In this paper the successful implementation of a thermal desorption step in single-particle mass spectrometry is described (TD-REMPI-SP-TOFMS). After size determination by particle velocimetry, individual particles are thermally desorbed on a heated surface in the ion source of the TOFMS. Desorbed molecules are ionized subsequently by REMPI, which addresses selectively PAH and molecular trace indicators. The TD-REMPI-SP-TOFMS concept was tested with reference particles and applied for automotive exhaust and ambient monitoring. The comparison of the results with the ones obtained by the two-laser approach (LD-REMPI-SP-TOFMS) indicates that the patented TD-REMPI-SP-TOFMS technology presented here is nearly equally well

  1. Uncertainty Evaluation of the Ratioes of Uranium Isotope Adundances Measured by Thermal Ionization Mass Spectrometer MAT-261%MAT261热表面电离质谱计测量数据不确定度评定

    Institute of Scientific and Technical Information of China (English)

    徐江; 朱凤蓉; 李志明

    2004-01-01

    The data of uranium isotope abundance ratios measured by thermal ionization mass spectrometer MAT-261 were analyzed in the three aspects including distribution function, correlation and uncertainty. The measurement data were confirmed to be normal distribution. Uncertainty and correlation of the isotope abundance ratios measured by MAT-261 in the certified uranium sample were investigated. The conclusion obtained indicated that, the correlation only between abundance ratios R5/8 and R4/8 is strong, but the others is weak for the enriched uranium sample; For the natural uranium sample, the correlation among all abundance ratios is weak. On this base, the uncertainty of all abundance ratios measured by MAT-261 had been evaluated.

  2. Impact of Total Ionizing Dose Radiation Testing and Long-Term Thermal Cycling on the Operation of CMF20120D Silicon Carbide Power MOSFET

    Science.gov (United States)

    Patterson, Richard L.; Scheidegger, Robert J.; Lauenstein, Jean-Marie; Casey, Megan; Scheick, Leif; Hammoud, Ahmad

    2013-01-01

    Power systems designed for use in NASA space missions are required to work reliably under harsh conditions including radiation, thermal cycling, and extreme temperature exposures. Silicon carbide devices show great promise for use in future power electronics systems, but information pertaining to performance of the devices in the space environment is very scarce. A silicon carbide N-channel enhancement-mode power MOSFET called the CMF20120 is of interest for use in space environments. Samples of the device were exposed to radiation followed by long-term thermal cycling to address their reliability for use in space applications. The results of the experimental work are presentd and discussed.

  3. Exciton ionization in multilayer transition-metal dichalcogenides

    DEFF Research Database (Denmark)

    Pedersen, Thomas Garm; Latini, Simone; Thygesen, Kristian Sommer;

    2016-01-01

    Photodetectors and solar cells based on materials with strongly bound excitons rely crucially on field-assisted exciton ionization. We study the ionization process in multilayer transition-metal dichalcogenides (TMDs) within the Mott-Wannier model incorporating fully the pronounced anisotropy......-principles material parameters, an analysis of several important TMDs reveals WSe2 and MoSe2 to be superior for applications relying on ionization of direct and indirect excitons, respectively....

  4. Fractionation of Oxygen Isotopes by Thermal Ionization Mass Spectrometry Inferred from Simultaneous Measurement of (17)O/(16)O and (18)O/(16)O Ratios and Implications for the (182)Hf-(182)W Systematics.

    Science.gov (United States)

    Trinquier, Anne

    2016-06-07

    Accurate (182)Hf-(182)W chronology of early planetary differentiation relies on highly precise and accurate tungsten isotope measurements. WO3(-) analysis by negative thermal ionization mass spectrometry requires W(17)O(16)O2(-), W(17)O2(16)O(-), W(18)O(16)O2(-), W(17)O3(-), W(17)O(18)O(16)O(-), and W(18)O2(16)O(-) isotopologue interference corrections on W(16)O3(-) species ( Harper et al. Geochim. Cosmochim. Acta 1996 , 60 , 1131 ; Quitté et al. Geostandard. Newslett. 2002 , 26 , 149 ; Trinquier et al. Anal. Chem. 2016 , 88 , 1542 ; Touboul et al. Nature 2015 , 520 , 530 ; Touboul et al. Int. J. Mass Spectrom. 2012 , 309 , 109 ). In addition, low ion beam intensity counting statistics combined with Faraday cup detection noise limit the precision on the determination of (18)O/(16)O and (17)O/(16)O relative abundances. Mass dependent variability of (18)O/(16)O over the course of an analysis and between different analyses calls for oxide interference correction on a per integration basis, based on the in-run monitoring of the (18)O/(16)O ratio ( Harper et al. Geochim. Cosmochim. Acta 1996 , 60 , 1131 ; Quitté et al. Geostandard. Newslett. 2002 , 26 , 149 ; Trinquier et al. Anal. Chem. 2016 , 88 , 1542 ). Yet, the (17)O/(16)O variation is normally not being monitored and, instead, inferred from the measured (18)O/(16)O variation, assuming a δ(17)O-δ(18)O Terrestrial Fractionation Line ( Trinquier et al. Anal. Chem. 2016 , 88 , 1542 ). The purpose of the present study is to verify the validity of this assumption. Using high resistivity amplifiers, (238)U(17)O2 and (238)U(18)O2 ion beams down to 1.6 fA have been monitored simultaneously with (235,238)U(16)O2 species in a uranium certified reference material. This leads to a characterization of O isotope fractionation by thermal ionization mass spectrometry in variable loading and running conditions (additive-to-sample ratio, PO2 pressure, presence of ionized metal and oxide species). Proper determination of O

  5. Superior Hiking Trail

    Data.gov (United States)

    Minnesota Department of Natural Resources — Superior Hiking Trail main trail, spurs, and camp spurs for completed trail throughout Cook, Lake, St. Louis and Carlton counties. These data were collected with...

  6. Bathymetry of Lake Superior

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Bathymetry of Lake Superior has been compiled as a component of a NOAA project to rescue Great Lakes lake floor geological and geophysical data and make it more...

  7. Superior Hiking Trail Facilities

    Data.gov (United States)

    Minnesota Department of Natural Resources — Superior Hiking Trail main trail, spurs, and camp spurs for completed trail throughout Cook, Lake, St. Louis and Carlton counties. These data were collected with...

  8. PERSISTENT LEFT SUPERIOR VENACAVA

    Directory of Open Access Journals (Sweden)

    Devinder Singh

    2014-05-01

    Full Text Available A Persistent Left Superior Venacava (PLSVC is the most common variation of the thoracic venous system and rare congenital vascular anomaly and is prevalent in 0.3% of the population. It may be associated with other cardiovascular abnormalities including atrial septal defect, bicuspid aortic valve, coarctation of aorta, coronary sinus ostial atresia, and cor triatriatum. Incidental rotation of a dilated coronary sinus on echocardiography should raise the suspicion of PLSVC. The diagnosis should be confirmed by saline contrast echocardiography. Condition is usually asymptomatic. Here we present a rare case of persistent left superior vena cava presented in OPD with dyspnoea & palpitations.

  9. Mass spectrometry of solid samples in open air using combined laser ionization and ambient metastable ionization

    Science.gov (United States)

    He, X. N.; Xie, Z. Q.; Gao, Y.; Hu, W.; Guo, L. B.; Jiang, L.; Lu, Y. F.

    2012-01-01

    Mass spectrometry of solid samples in open air was carried out using combined laser ionization and metastable ionization time-of-flight mass spectrometry (LI-MI-TOFMS) in ambient environment for qualitative and semiquantitative (relative analyte information, not absolute information) analysis. Ambient metastable ionization using a direct analysis in realtime (DART) ion source was combined with laser ionization time-of-flight mass spectrometry (LI-TOFMS) to study the effects of combining metastable and laser ionization. A series of metallic samples from the National Institute of Standards and Technology (NIST 494, 495, 498, 499, and 500) and a pure carbon target were characterized using LI-TOFMS in open air. LI-MI-TOFMS was found to be superior to laser-induced breakdown spectroscopy (LIBS). Laser pulse energies between 10 and 200 mJ at the second harmonic (532 nm) of an Nd:YAG laser were applied in the experiment to obtain a high degree of ionization in plasmas. Higher laser pulse energy improves signal intensities of trace elements (such as Fe, Cr, Mn, Ni, Ca, Al, and Ag). Data were analyzed by numerically calculating relative sensitivity coefficients (RSCs) and limit of detections (LODs) from mass spectrometry (MS) and LIBS spectra. Different parameters, such as boiling point, ionization potential, RSC, LOD, and atomic weight, were shown to analyze the ionization and MS detection processes in open air.

  10. Development of Thermal Dissociation Atmospheric Chemical Ionization Source for Rapid Mass Spectrometric Analysis of Ambient Samples%常压热解离化学电离源的研制及表征

    Institute of Scientific and Technical Information of China (English)

    韩京; 李建强; 张燮; 胡斌; 罗明标; 陈焕文

    2011-01-01

    A novel thermal dissociation atmospheric chemical ionization source (TDCI) was developed for rapid chemical ionization of ambient analytes in complex matrices. By coupling the TDCI source to a commercial LTQ XL mass spectrometer, the dissociation of chemical reagents such as ionic liquids was systematically investigated using multiple-stage mass spectrometric experiments. The primary ions generated through the thermal dissociation process of the ionic liquids were accelerated by the high voltage applied on the repelling electrode of the TDCI source, and then reacted with the analytes present in the matrices of the raw samples to produce ions of analytes, which were then guided to the LTQ instrument for mass analysis. The construction of the TDCI source was detailed in the text. The effects of the experimental parameters such as the pyrolysis temperature, the distance, and the angles formed between the electrodes were experimentally studied using the signals of characteristic fragments of the ionic liquid. Under the optimal experimental parameters, TDCI was able to directly ionize a wide variety of compounds, including the poplar (e.g., amino acids, doping compounds) and non-polar chemicals (e.g, naphthalene) for sensitive detection using LTQ-MS, without any sample pretreatment. The average time for a single sample analysis was less than 30 s, and the relative standard deviation of the method was in the range of 5.9%- 11.1 %; the LOD for naphthalene was estimated to be 2.93 × 10-7 g/L.%自行研制了常压热解离化学电离源(TDCI),与商品化LTQ XL质谱仪成功联用,进一步考察了TDCI的性能,并对其应用领域进行了初步探索.TDCI-MS/MS谱图表明,离子液体可在现有实验条件下产生特征离子碎片;升高TDCI源偏置电压和温度,可以提高离子液体的信号强度.基于优化后的实验参数,常压热解离化学电离质谱方法(TDCI-MS)可以有效检测沙丁胺醇和萘等极性与非极性物质.本方法

  11. Direct High-Precision Measurements of the (87)Sr/(86)Sr Isotope Ratio in Natural Water without Chemical Separation Using Thermal Ionization Mass Spectrometry Equipped with 10(12) Ω Resistors.

    Science.gov (United States)

    Li, Chao-Feng; Guo, Jing-Hui; Chu, Zhu-Yin; Feng, Lian-Jun; Wang, Xuan-Ce

    2015-07-21

    Thermal ionization mass spectrometry (TIMS) allows excellent precision for determining Sr isotope ratios in natural water samples. Traditionally, a chemical separation procedure using cation exchange resin has been employed to obtain a high purity Sr fraction from natural water, which makes sample preparation time-consuming. In this study, we present a rapid and precise method for the direct determination of the Sr isotope ratio of natural water using TIMS equipped with amplifiers with two 10(12) Ω resistors. To eliminate the (87)Rb isobaric interference, Re ribbons are used as filaments, providing a significant advantage over W ribbons in the inhibition of Rb(+) emission, based on systematically examining a series of NIST SRM987 standard doping with various amounts of Rb using Re and W ribbons. To validate the applicability of our method, twenty-two natural water samples, including different water types (rain, snow, river, lake and drinking water), that show a large range in Sr content variations (2.54-922.8 ppb), were collected and analyzed from North and South China. Analytical results show good precision (0.003-0.005%, 2 RSE) and the method was further validated by comparative analysis of the same water with and without chemical separation. The method is simple and rapid, eliminates sample preparation time, and prevents potential contamination during complicated sample-preparation procedures. Therefore, a high sample throughput inherent to the TIMS can be fully utilized.

  12. Ionization Energies of Lanthanides

    Science.gov (United States)

    Lang, Peter F.; Smith, Barry C.

    2010-01-01

    This article describes how data are used to analyze the pattern of ionization energies of the lanthanide elements. Different observed pathways of ionization between different ground states are discussed, and the effects of pairing, exchange, and orbital interactions on ionization energies of the lanthanides are evaluated. When all the above…

  13. Air Superiority Fighter Characteristics.

    Science.gov (United States)

    1998-06-05

    many a dispute could have been deflated into a single paragraph if the disputants had just dared to define their terms.7 Aristotle ...meaningful. This section will expand on some key ideology concepts. The phrase "air superiority fighter" may bring to mind visions of fighter... biographies are useful in garnering airpower advocate theories as well as identifying key characteristics. Air campaign results, starting with World

  14. Improved field emission properties of carbon nanotubes grown on stainless steel substrate and its application in ionization gauge

    Energy Technology Data Exchange (ETDEWEB)

    Li, Detian; Cheng, Yongjun [Science and Technology on Vacuum Technology and Physics Laboratory, Lanzhou Institute of Physics, Lanzhou 730000 (China); Wang, Yongjun, E-mail: wyjlxlz@163.com [Science and Technology on Vacuum Technology and Physics Laboratory, Lanzhou Institute of Physics, Lanzhou 730000 (China); Zhang, Huzhong [Science and Technology on Vacuum Technology and Physics Laboratory, Lanzhou Institute of Physics, Lanzhou 730000 (China); Dong, Changkun [Institute of Micro-Nano Structures and Optoelectronics, Wenzhou University, Wenzhou 325035 (China); Li, Da [Division of Advanced Nanomaterials, Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou 215125 (China)

    2016-03-01

    Graphical abstract: - Highlights: • The high quality CNT arrays were successfully grown on conductive stainless steel substrates. • The CNT array grown on stainless steel substrate exhibited superior field emission properties. • A high vacuum level about 10–8 Pa was measured by resultant CNT-based ionization gauge. • The ionization gauge with CNT cathode demonstrated a high stability. - Abstract: Vertically aligned carbon nanotube (CNT) arrays were fabricated by chemical vapor deposition (CVD) technique on different substrates. Microstructures and field emission characteristics of the as-grown CNT arrays were investigated systematically, and its application in ionization gauge was also evaluated preliminarily. The results indicate that the as-grown CNT arrays are vertically well-aligned relating to the substrate surfaces, but the CNTs grown on stainless steel substrate are longer and more crystalline than the ones grown on silicon wafer substrate. The field emission behaviors of the as-grown CNT arrays are strongly dependent upon substrate properties. Namely, the CNT array grown on stainless steel substrate has better field emission properties, including lower turn on and threshold fields, better emission stability and repeatability, compared with the one grown on silicon wafer substrate. The superior field emission properties of the CNT array grown on stainless steel substrate are mainly attributed to low contact resistance, high thermal conductivity, good adhesion strength, etc. In addition, the metrological behaviors of ionization gauge with the CNT array grown on stainless steel substrate as an electron source were investigated, and this novel cathode ionization gauge extends the lower limit of linear pressure measurement to 10{sup −8} Pa, which is one order of magnitude lower than the result reported for the same of gauge with CNT cathode.

  15. Contabilidad Financiera Superior

    OpenAIRE

    Ipiñazar Petralanda, Izaskun

    2013-01-01

    Duración (en horas): De 31 a 40 horas. Destinatario: Estudiante y Docente A través de este material se presentan las pautas necesarias para implementar un aprendizaje basado en problemas en la asignatura de Contabilidad Financiera Superior dentro de los temas “Constitución de S.A. y S.R.L.” (Tema 2), “Ampliaciones de Capital” (Tema 3) y “Reducciones de Capital” (Tema 4). En primer lugar se presentan las guías generales de la asignatura, y a continuación, las diferentes activida...

  16. Contabilidad Financiera Superior

    OpenAIRE

    Ipiñazar Petralanda, Izaskun

    2013-01-01

    Duración (en horas): De 31 a 40 horas. Destinatario: Estudiante y Docente A través de este material se presentan las pautas necesarias para implementar un aprendizaje basado en problemas en la asignatura de Contabilidad Financiera Superior dentro de los temas “Constitución de S.A. y S.R.L.” (Tema 2), “Ampliaciones de Capital” (Tema 3) y “Reducciones de Capital” (Tema 4). En primer lugar se presentan las guías generales de la asignatura, y a continuación, las diferentes activida...

  17. Statistics of superior records

    Science.gov (United States)

    Ben-Naim, E.; Krapivsky, P. L.

    2013-08-01

    We study statistics of records in a sequence of random variables. These identical and independently distributed variables are drawn from the parent distribution ρ. The running record equals the maximum of all elements in the sequence up to a given point. We define a superior sequence as one where all running records are above the average record expected for the parent distribution ρ. We find that the fraction of superior sequences SN decays algebraically with sequence length N, SN˜N-β in the limit N→∞. Interestingly, the decay exponent β is nontrivial, being the root of an integral equation. For example, when ρ is a uniform distribution with compact support, we find β=0.450265. In general, the tail of the parent distribution governs the exponent β. We also consider the dual problem of inferior sequences, where all records are below average, and find that the fraction of inferior sequences IN decays algebraically, albeit with a different decay exponent, IN˜N-α. We use the above statistical measures to analyze earthquake data.

  18. Frenillo labial superior doble

    Directory of Open Access Journals (Sweden)

    Carlos Albornoz López del Castillo

    Full Text Available El frenillo labial superior doble no sindrómico es una anomalía del desarrollo que no hemos encontrado reportada en la revisión bibliográfica realizada. Se presenta una niña de 11 años de edad que fue remitida al servicio de Cirugía Maxilofacial del Hospital "Eduardo Agramonte Piña", de Camagüey, por presentar un frenillo labial superior doble de baja inserción. Se describen los síntomas clínicos asociados a esta anomalía y el tratamiento quirúrgico utilizado para su solución: una frenectomía y plastia sobre la banda muscular frénica anormal que provocaba exceso de tejido en la mucosa labial. Consideramos muy interesante la descripción de este caso, por no haber encontrado reporte similar en la literatura revisada.

  19. Development of a new multi-residue laser diode thermal desorption atmospheric pressure chemical ionization tandem mass spectrometry method for the detection and quantification of pesticides and pharmaceuticals in wastewater samples.

    Science.gov (United States)

    Boisvert, Michel; Fayad, Paul B; Sauvé, Sébastien

    2012-11-19

    A new solid phase extraction (SPE) method coupled to a high throughput sample analysis technique was developed for the simultaneous determination of nine selected emerging contaminants in wastewater (atrazine, desethylatrazine, 17β-estradiol, ethynylestradiol, norethindrone, caffeine, carbamazepine, diclofenac and sulfamethoxazole). We specifically included pharmaceutical compounds from multiple therapeutic classes, as well as pesticides. Sample pre-concentration and clean-up was performed using a mixed-mode SPE cartridge (Strata ABW) having both cation and anion exchange properties, followed by analysis by laser diode thermal desorption atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD-APCI-MS/MS). The LDTD interface is a new high-throughput sample introduction method, which reduces total analysis time to less than 15s per sample as compared to minutes with traditional liquid-chromatography coupled to tandem mass spectrometry (LC-MS/MS). Several SPE parameters were evaluated in order to optimize recovery efficiencies when extracting analytes from wastewater, such as the nature of the stationary phase, the loading flow rate, the extraction pH, the volume and composition of the washing solution and the initial sample volume. The method was successfully applied to real wastewater samples from the primary sedimentation tank of a municipal wastewater treatment plant. Recoveries of target compounds from wastewater ranged from 78% to 106%, the limit of detection ranged from 30 to 122ng L(-1) while the limit of quantification ranged from 90 to 370ng L(-1). Calibration curves in the wastewater matrix showed good linearity (R(2)≥0.991) for all target analytes and the intraday and interday coefficient of variation was below 15%, reflecting a good precision.

  20. High-Precision Tungsten Isotopic Analysis by Multicollection Negative Thermal Ionization Mass Spectrometry Based on Simultaneous Measurement of W and (18)O/(16)O Isotope Ratios for Accurate Fractionation Correction.

    Science.gov (United States)

    Trinquier, Anne; Touboul, Mathieu; Walker, Richard J

    2016-02-02

    Determination of the (182)W/(184)W ratio to a precision of ± 5 ppm (2σ) is desirable for constraining the timing of core formation and other early planetary differentiation processes. However, WO3(-) analysis by negative thermal ionization mass spectrometry normally results in a residual correlation between the instrumental-mass-fractionation-corrected (182)W/(184)W and (183)W/(184)W ratios that is attributed to mass-dependent variability of O isotopes over the course of an analysis and between different analyses. A second-order correction using the (183)W/(184)W ratio relies on the assumption that this ratio is constant in nature. This may prove invalid, as has already been realized for other isotope systems. The present study utilizes simultaneous monitoring of the (18)O/(16)O and W isotope ratios to correct oxide interferences on a per-integration basis and thus avoid the need for a double normalization of W isotopes. After normalization of W isotope ratios to a pair of W isotopes, following the exponential law, no residual W-O isotope correlation is observed. However, there is a nonideal mass bias residual correlation between (182)W/(i)W and (183)W/(i)W with time. Without double normalization of W isotopes and on the basis of three or four duplicate analyses, the external reproducibility per session of (182)W/(184)W and (183)W/(184)W normalized to (186)W/(183)W is 5-6 ppm (2σ, 1-3 μg loads). The combined uncertainty per session is less than 4 ppm for (183)W/(184)W and less than 6 ppm for (182)W/(184)W (2σm) for loads between 3000 and 50 ng.

  1. Ionization in Atmospheres of Brown Dwarfs and Extrasolar Planets V: Alfv\\'{e}n Ionization

    CERN Document Server

    Stark, Craig R; Diver, Declan A; Rimmer, Paul B

    2013-01-01

    Observations of continuous radio and sporadic X-ray emission from low-mass objects suggest they harbour localized plasmas in their atmospheric environments. For low-mass objects, the degree of thermal ionization is insufficient to qualify the ionized component as a plasma, posing the question: what ionization processes can efficiently produce the required plasma that is the source of the radiation? We propose Alfv\\'{e}n ionization as a mechanism for producing localized pockets of ionized gas in the atmosphere, having sufficient degrees of ionization ($\\geq10^{-7}$) that they constitute plasmas. We outline the criteria required for Alfv\\'{e}n ionization and demonstrate it's applicability in the atmospheres of low-mass objects such as giant gas planets, brown dwarfs and M-dwarfs for both solar and sub-solar metallicities. We find that Alfv\\'{e}n ionization is most efficient at mid to low atmospheric pressures where a seed plasma is easier to magnetize and the pressure gradients needed to drive the required neut...

  2. Electronic transport in partially ionized water plasmas

    Science.gov (United States)

    French, Martin; Redmer, Ronald

    2017-09-01

    We use ab initio simulations based on density functional theory to calculate the electrical and thermal conductivities of electrons in partially ionized water plasmas at densities above 0.1 g/cm3. The resulting conductivity data are then fitted to analytic expressions for convenient application. For low densities, we develop a simple and fully analytic model for electronic transport in low-density plasmas in the chemical picture using the relaxation-time approximation. In doing so, we derive a useful analytic expression for electronic transport cross sections with neutral particles, based on a model potential. In the regime of thermal ionization, electrical conductivities from the analytic model agree with the ab initio data within a factor of 2. Larger deviations are observed for the thermal conductivity, and their origin is discussed. Our results are relevant for modeling the interior and evolution of water-rich planets as well as for technical plasma applications.

  3. Sobredentadura total superior implantosoportada

    Directory of Open Access Journals (Sweden)

    Luis Orlando Rodríguez García

    2010-06-01

    Full Text Available Se presenta un caso de un paciente desdentado total superior, rehabilitado en la consulta de implantología de la Clínica "Pedro Ortiz" del municipio Habana del Este en Ciudad de La Habana, Cuba, en el año 2009, mediante prótesis sobre implantes osteointegrados, técnica que se ha incorporado a la práctica estomatológica en Cuba como alternativa al tratamiento convencional en los pacientes desdentados totales. Se siguió un protocolo que comprendió una fase quirúrgica, procedimiento con o sin realización de colgajo y carga precoz o inmediata. Se presenta un paciente masculino de 56 años de edad, que acudió a la consulta multidisciplinaria, preocupado, porque se le habían elaborado tres prótesis en los últimos dos años y ninguna reunía los requisitos de retención que él necesitaba para sentirse seguro y cómodo con las mismas. El resultado final fue la satisfacción total del paciente, con el mejoramiento de la calidad estética y funcional.

  4. Methanol chemical ionization quadrupole ion trap mass spectrometry of O-ethyl S-[2-(diisopropylamino)ethyl] methylphosphonothiolate (VX) and its degradation products.

    Science.gov (United States)

    Rohrbaugh, D K

    2000-10-06

    Mass spectrometric analysis of O-ethyl S-[2-(diisopropylamino)ethyl] methylphosphonothiolate (VX) degradation products by electron ionization produces extensive fragmentation with little or no molecular ion information making product identification difficult. Milder chemical ionization (CI) is commonly used to provide molecular mass and structure confirmation. In this study, methanol was used as a CI reagent in combination with an ion trap detector for detection and identification of over 30 compounds present in a thermally degraded sample of VX. The use of methanol provides superior results for this class of compounds with less fragmentation than commonly observed with gas reagents and offers logistical advantages for on-site analysis by being easier to transport and safer to use than gas cylinders.

  5. Biological Effects of Ionizing Radiation

    Science.gov (United States)

    Ingram, M.; Mason, W. B.; Whipple, G. H.; Howland, J. W.

    1952-04-07

    This report presents a review of present knowledge and concepts of the biological effects of ionizing radiations. Among the topics discussed are the physical and chemical effects of ionizing radiation on biological systems, morphological and physiological changes observed in biological systems subjected to ionizing radiations, physiological changes in the intact animal, latent changes following exposure of biological systems to ionizing radiations, factors influencing the biological response to ionizing radiation, relative effects of various ionizing radiations, and biological dosimetry.

  6. Abnormal ionization in sonoluminescence

    Science.gov (United States)

    Zhang, Wen-Juan; An, Yu

    2015-04-01

    Sonoluminescence is a complex phenomenon, the mechanism of which remains unclear. The present study reveals that an abnormal ionization process is likely to be present in the sonoluminescing bubble. To fit the experimental data of previous studies, we assume that the ionization energies of the molecules and atoms in the bubble decrease as the gas density increases and that the decrease of the ionization energy reaches about 60%-70% as the bubble flashes, which is difficult to explain by using previous models. Project supported by the Research Fund for the Doctoral Program of Higher Education of China (Grant No. 20120002110031) and the National Natural Science Foundation of China (Grant No. 11334005).

  7. Optimum strategy for energy degraders and ionization cooling

    CERN Document Server

    Farley, F J M

    2004-01-01

    Methodology for calculating the profile and emittance of a particle beam as it is slowed down in matter, including the effects of multiple scattering, axial magnetic field and lithium lens. Strategies are determined for minimum final emittance. For ionization cooling, boron carbide is superior to liquid hydrogen while a beryllium lens has merit.

  8. Electron ionization of acetylene.

    Science.gov (United States)

    King, Simon J; Price, Stephen D

    2007-11-07

    Relative partial ionization cross sections and precursor specific relative partial ionization cross sections for fragment ions formed by electron ionization of C2H2 have been measured using time-of-flight mass spectrometry coupled with a 2D ion-ion coincidence technique. We report data for the formation of H+, H+2, C2+, C+/C2+ 2, CH+/C2H+2, CH+2, C+2, and C2H+ relative to the formation of C2H+2, as a function of ionizing electron energy from 30-200 eV. While excellent agreement is found between our data and one set of previously published absolute partial ionization cross sections, some discrepancies exist between the results presented here and two other recent determinations of these absolute partial ionization cross sections. We attribute these differences to the loss of some translationally energetic fragment ions in these earlier studies. Our relative precursor-specific partial ionization cross sections enable us, for the first time, to quantify the contribution to the yield of each fragment ion from single, double, and triple ionization. Analysis shows that at 50 eV double ionization contributes 2% to the total ion yield, increasing to over 10% at an ionizing energy of 100 eV. From our ion-ion coincidence data, we have derived branching ratios for charge separating dissociations of the acetylene dication. Comparison of our data to recent ab initio/RRKM calculations suggest that close to the double ionization potential C2H2+2 dissociates predominantly on the ground triplet potential energy surface (3Sigma*g) with a much smaller contribution from dissociation via the lowest singlet potential energy surface (1Delta g). Measurements of the kinetic energy released in the fragmentation reactions of C2H2+2 have been used to obtain precursor state energies for the formation of product ion pairs, and are shown to be in good agreement with available experimental data and with theory.

  9. "Magic" Ionization Mass Spectrometry

    Science.gov (United States)

    Trimpin, Sarah

    2016-01-01

    The systematic study of the temperature and pressure dependence of matrix-assisted ionization (MAI) led us to the discovery of the seemingly impossible, initially explained by some reviewers as either sleight of hand or the misinterpretation by an overzealous young scientist of results reported many years before and having little utility. The "magic" that we were attempting to report was that with matrix assistance, molecules, at least as large as bovine serum albumin (66 kDa), are lifted into the gas phase as multiply charged ions simply by exposure of the matrix:analyte sample to the vacuum of a mass spectrometer. Applied heat, a laser, or voltages are not necessary to achieve charge states and ion abundances only previously observed with electrospray ionization (ESI). The fundamentals of how solid phase volatile or nonvolatile compounds are converted to gas-phase ions without added energy currently involves speculation providing a great opportunity to rethink mechanistic understanding of ionization processes used in mass spectrometry. Improved understanding of the mechanism(s) of these processes and their connection to ESI and matrix-assisted laser desorption/ionization may provide opportunities to further develop new ionization strategies for traditional and yet unforeseen applications of mass spectrometry. This Critical Insights article covers developments leading to the discovery of a seemingly magic ionization process that is simple to use, fast, sensitive, robust, and can be directly applied to surface characterization using portable or high performance mass spectrometers.

  10. Transport properties of partially ionized hydrogen plasma

    Energy Technology Data Exchange (ETDEWEB)

    Ramazanov, T S [IETP, Al Farabi Kazakh National University, Tole bi, 96a, 480012, Almaty (Kazakhstan); Galiyev, K Zh [IETP, Al Farabi Kazakh National University, Tole bi, 96a, 480012, Almaty (Kazakhstan); Dzhumagulova, K N [IETP, Al Farabi Kazakh National University, Tole bi, 96a, 480012, Almaty (Kazakhstan); Roepke, G [Fachbereich Physik, Universitaet Rostock, D-18051 Rostock (Germany); Redmer, R [Fachbereich Physik, Universitaet Rostock, D-18051 Rostock (Germany)

    2003-06-06

    We have considered partially ionized hydrogen plasma for the density region n{sub e} = (10{sup 18}-10{sup 22}) cm{sup -3}. Charged particles in the system (electrons, protons) interact via an effective potential taking into account three-particle correlations. We use the Buckingham polarization potential to describe electron-atom and proton-atom interactions. The electrical and thermal conductivity is determined using the Chapman-Enskog method. We compare the obtained results with other available data.

  11. Improved field emission properties of carbon nanotubes grown on stainless steel substrate and its application in ionization gauge

    Science.gov (United States)

    Li, Detian; Cheng, Yongjun; Wang, Yongjun; Zhang, Huzhong; Dong, Changkun; Li, Da

    2016-03-01

    Vertically aligned carbon nanotube (CNT) arrays were fabricated by chemical vapor deposition (CVD) technique on different substrates. Microstructures and field emission characteristics of the as-grown CNT arrays were investigated systematically, and its application in ionization gauge was also evaluated preliminarily. The results indicate that the as-grown CNT arrays are vertically well-aligned relating to the substrate surfaces, but the CNTs grown on stainless steel substrate are longer and more crystalline than the ones grown on silicon wafer substrate. The field emission behaviors of the as-grown CNT arrays are strongly dependent upon substrate properties. Namely, the CNT array grown on stainless steel substrate has better field emission properties, including lower turn on and threshold fields, better emission stability and repeatability, compared with the one grown on silicon wafer substrate. The superior field emission properties of the CNT array grown on stainless steel substrate are mainly attributed to low contact resistance, high thermal conductivity, good adhesion strength, etc. In addition, the metrological behaviors of ionization gauge with the CNT array grown on stainless steel substrate as an electron source were investigated, and this novel cathode ionization gauge extends the lower limit of linear pressure measurement to 10-8 Pa, which is one order of magnitude lower than the result reported for the same of gauge with CNT cathode.

  12. Electrospray ionization of volatiles in breath

    Science.gov (United States)

    Martínez-Lozano, P.; de La Mora, J. Fernández

    2007-08-01

    Recent work by Zenobi and colleagues [H. Chen, A. Wortmann, W. Zhang, R. Zenobi, Angew. Chem. Int. Ed. 46 (2007) 580] reports that human breath charged by contact with an electrospray (ES) cloud yields many mass peaks of species such as urea, glucose, and other ions, some with molecular weights above 1000 Da. All these species are presumed to be involatile, and to originate from breath aerosols by so-called extractive electrospray ionization EESI [H. Chen, A. Venter, R.G. Cooks, Chem. Commun. (2006) 2042]. However, prior work by Fenn and colleagues [C.M. Whitehouse, F. Levin, C.K. Meng, J.B. Fenn, Proceedings of the 34th ASMS Conference on Mass Spectrometry and Allied Topics, Denver, 1986 p. 507; S. Fuerstenau, P. Kiselev, J.B. Fenn, Proceedings of the 47th ASMS Conference on Mass Spectrometry, 1999, Dallas, TX, 1999] and by Hill and colleagues [C. Wu, W.F. Siems, H.H. Hill Jr., Anal. Chem. 72 (2000) 396] have reported the ability of electrospray drops to ionize a variety of low vapor pressure substances directly from the gas phase, without an apparent need for the vapor to be brought into the charging ES in aerosol form. The Ph.D. Thesis of Martínez-Lozano [P. Martínez-Lozano Sinués, Ph.D. Thesis, Department of Thermal and Fluid Engineering, University Carlos III of Madrid; April 5, 2006 (in Spanish); http://hdl.handle.net/10016/655] had also previously argued that the numerous human breath species observed via a similar ES ionization approach were in fact ionized directly from the vapor. Here, we observe that passage of the breath stream through a submicron filter does not eliminate the majority of the breath vapors seen in the absence of the filter. We conclude that direct vapor charging is the leading mechanism in breath ionization by electrospray drops, though aerosol ionization may also play a role.

  13. Ionization beam scanner

    CERN Multimedia

    CERN PhotoLab

    1973-01-01

    Inner structure of an ionization beam scanner, a rather intricate piece of apparatus which permits one to measure the density distribution of the proton beam passing through it. On the outside of the tank wall there is the coil for the longitudinal magnetic field, on the inside, one can see the arrangement of electrodes creating a highly homogeneous transverse electric field.

  14. 75 FR 28542 - Superior Resource Advisory Committee

    Science.gov (United States)

    2010-05-21

    ... orient the new Superior Resource Advisory Committee members on their roles and responsibilities. DATES... of the roles and responsibilities of the Superior Resource Advisory Committee members; Election of... Forest Service Superior Resource Advisory Committee AGENCY: Forest Service, USDA. ACTION: Notice...

  15. [The superior laryngeal nerve and the superior laryngeal artery].

    Science.gov (United States)

    Lang, J; Nachbaur, S; Fischer, K; Vogel, E

    1987-01-01

    Length, diameter and anastomoses of the nervus vagus and its ganglion inferius were measured 44 halved heads. On the average, 8.65 fiber bundles of the vagus nerve leave the retro-olivary area. In the area of the jugular foramen is the near superior ganglion of the 10th cranial nerve. In this area were found 1.48 (mean value) anastomoses with the 9th cranial nerve. 11.34 mm below the margo terminalis sigmoidea branches off the ramus internus of the accessory nerve which has a length of 9.75 mm. Further anastomoses with the 10th cranial nerve were found. The inferior ganglion of the 10th nerve had a length of 25.47 mm and a diameter of 3.46 mm. Five mm below the ganglion the 10th nerve had a width of 2.9 and a thickness of 1.5 mm. The mean length of the superior sympathetic ganglion was 26.6 mm, its width 7.2 and its thickness 3.4 mm. In nearly all specimens anastomoses of the superior sympathetic ganglion with the ansa cervicalis profunda and the inferior ganglion of the 10th cranial nerve were found. The superior laryngeal nerve branches off about 36 mm below the margo terminalis sigmoidea. The width of this nerve was 1.9 mm, its thickness 0.8 mm on the right and 1.0 mm on the left side. The division in the internal and external rami was found about 21 mm below its origin. Between the n. vagus and thyreohyoid membrane the ramus internus had a length of 64 mm, the length of external ramus between the vagal nerve and the inferior pharyngeal constrictor muscle was 89 mm. Its mean length below the thyreopharyngeal part was 10.7 mm, 8.6 branchlets to the cricothyroid muscle were counted. The superior laryngeal artery had its origin in 80% of cases in the superior thyroideal artery, in 6.8% this vessel was a branch of the external carotid artery. Its average outer diameter was 1.23 mm on the right side and 1.39 mm on the left. The length of this vessel between its origin and the thyreohyoid membrane was 34 mm. In 7% on the right side and in 13% on the left, the superior

  16. Dynamic thermal environment and thermal comfort.

    Science.gov (United States)

    Zhu, Y; Ouyang, Q; Cao, B; Zhou, X; Yu, J

    2016-02-01

    Research has shown that a stable thermal environment with tight temperature control cannot bring occupants more thermal comfort. Instead, such an environment will incur higher energy costs and produce greater CO2 emissions. Furthermore, this may lead to the degeneration of occupants' inherent ability to combat thermal stress, thereby weakening thermal adaptability. Measured data from many field investigations have shown that the human body has a higher acceptance to the thermal environment in free-running buildings than to that in air-conditioned buildings with similar average parameters. In naturally ventilated environments, occupants have reported superior thermal comfort votes and much greater thermal comfort temperature ranges compared to air-conditioned environments. This phenomenon is an integral part of the adaptive thermal comfort model. In addition, climate chamber experiments have proven that people prefer natural wind to mechanical wind in warm conditions; in other words, dynamic airflow can provide a superior cooling effect. However, these findings also indicate that significant questions related to thermal comfort remain unanswered. For example, what is the cause of these phenomena? How we can build a comfortable and healthy indoor environment for human beings? This article summarizes a series of research achievements in recent decades, tries to address some of these unanswered questions, and attempts to summarize certain problems for future research.

  17. Secondary ionization and heating by fast electrons

    CERN Document Server

    Furlanetto, Steven

    2009-01-01

    We examine the fate of fast electrons (with energies E>10 eV) in a thermal gas of primordial composition. To follow their interactions with the background gas, we construct a Monte Carlo model that includes: (1) electron-electron scattering (which transforms the electron kinetic energy into heat), (2) collisional ionization of hydrogen and helium (which produces secondary electrons that themselves scatter through the medium), and (3) collisional excitation (which produces secondary photons, whose fates we also follow approximately). For the last process, we explicitly include all transitions to upper levels n<=4, together with a well-motivated extrapolation to higher levels. In all cases, we use recent calculated cross-sections at E<1 keV and the Bethe approximation to extrapolate to higher energies. We compute the fractions of energy deposited as heat, ionization (tracking HI and the helium species separately), and excitation (tracking HI Lyman-alpha separately) under a broad range of conditions approp...

  18. Shock Wave Dynamics in Weakly Ionized Plasmas

    Science.gov (United States)

    Johnson, Joseph A., III

    1999-01-01

    An investigation of the dynamics of shock waves in weakly ionized argon plasmas has been performed using a pressure ruptured shock tube. The velocity of the shock is observed to increase when the shock traverses the plasma. The observed increases cannot be accounted for by thermal effects alone. Possible mechanisms that could explain the anomalous behavior include a vibrational/translational relaxation in the nonequilibrium plasma, electron diffusion across the shock front resulting from high electron mobility, and the propagation of ion-acoustic waves generated at the shock front. Using a turbulence model based on reduced kinetic theory, analysis of the observed results suggest a role for turbulence in anomalous shock dynamics in weakly ionized media and plasma-induced hypersonic drag reduction.

  19. STEREO Superior Solar Conjunction Mission Phase

    Science.gov (United States)

    Ossing, Daniel A.; Wilson, Daniel; Balon, Kevin; Hunt, Jack; Dudley, Owen; Chiu, George; Coulter, Timothy; Reese, Angel; Cox, Matthew; Srinivasan, Dipak; hide

    2017-01-01

    With its long duration and high gain antenna (HGA) feed thermal constraint; the NASA Solar-TErestrial RElations Observatory (STEREO) solar conjunction mission phase is quite unique to deep space operations. Originally designed for a two year heliocentric orbit mission to primarily study coronal mass ejection propagation, after 8 years of continuous science data collection, the twin STEREO observatories entered the solar conjunction mission phase, for which they were not designed. Nine months before entering conjunction, an unforeseen thermal constraint threatened to stop daily communications and science data collection for 15months. With a 3.5 month long communication blackout from the superior solar conjunction, without ground commands, each observatory will reset every 3 days, resulting in 35 system resets at an Earth range of 2 AU. As the observatories will be conjoined for the first time in 8 years, a unique opportunity for calibrating the same instruments on identical spacecraft will occur. As each observatory has lost redundancy, and with only a limited fidelity hardware simulator, how can the new observatory configuration be adequately and safely tested on each spacecraft? Without ground commands, how would a 3-axis stabilized spacecraft safely manage the ever accumulating system momentum without using propellant for thrusters? Could science data still be collected for the duration of the solar conjunction mission phase? Would the observatories survive? In its second extended mission, operational resources were limited at best. This paper discusses the solutions to the STEREO superior solar conjunction operational challenges, science data impact, testing, mission operations, results, and lessons learned while implementing.

  20. What are Millian Qualitative Superiorities?

    Directory of Open Access Journals (Sweden)

    Jonathan Riley

    2008-04-01

    Full Text Available In an article published in Prolegomena 2006, Christoph Schmidt-Petri has defended his interpretation and attacked mine of Mill’s idea that higher kinds of pleasure are superior in quality to lower kinds, regardless of quantity. Millian qualitative superiorities as I understand them are infinite superiorities. In this paper, I clarify my interpretation and show how Schmidt-Petri has misrepresented it and ignored the obvious textual support for it. As a result, he fails to understand how genuine Millian qualitative superiorities determine the novel structure of Mill’s pluralistic utilitarianism, in which a social code of justice that distributes equal rights and duties takes absolute priority over competing considerations. Schmidt-Petri’s own interpretation is a non-starter, because it does noteven recognize that Mill is talking about different kinds of pleasant feelings, such that the higher kinds are intrinsically more valuable than the lower. I conclude by outlining why my interpretation is free of any metaphysical commitment to the “essence” of pleasure.

  1. Isolated superior mesenteric artery dissection

    Directory of Open Access Journals (Sweden)

    Lalitha Palle

    2010-01-01

    Full Text Available Isolated superior mesenteric artery (SMA dissection without involvement of the aorta and the SMA origin is unusual. We present a case of an elderly gentleman who had chronic abdominal pain, worse after meals. CT angiography, performed on a 64-slice CT scanner, revealed SMA dissection with a thrombus. A large artery of Drummond was also seen. The patient was managed conservatively.

  2. Venturi easy ambient sonic-spray ionization.

    Science.gov (United States)

    Santos, Vanessa G; Regiani, Thaís; Dias, Fernanda F G; Romão, Wanderson; Jara, Jose Luis Paz; Klitzke, Clécio F; Coelho, Fernando; Eberlin, Marcos N

    2011-02-15

    The development and illustrative applications of an ambient ionization technique termed Venturi easy ambient sonic-spray ionization (V-EASI) is described. Its dual mode of operation with Venturi self-pumping makes V-EASI applicable to the direct mass spectrometric analysis of both liquid (V(L)-EASI) and solid (V(S)-EASI) samples. V-EASI is simple and easy to assemble, operating solely via the assistance of a sonic stream of nitrogen or air. The sonic gas stream causes two beneficial and integrated effects: (a) the self-pumping of solutions via the Venturi effect and (b) sonic-spray ionization (SSI) of analytes either in solution or resting on solid surfaces. In its liquid mode, V(L)-EASI is applicable to analytes in solution, forming negatively and/or positively charged intact molecular species in a soft fashion with little or no fragmentation. In its solid mode, V(S)-EASI relies on Venturi self-pumping of a proper SSI solvent solution in combination with SSI to form a stream of bipolar charged droplets that bombard the sample surface, causing desorption and ionization of the analyte molecules. As for its precursor technique (EASI), V-EASI generates bipolar droplets with considerably lower average charging, which increases selectivity for ionization with high signal-to-noise ratios and clean spectra dominated by single molecular species with minimal solvent ions. V-EASI also operates in a voltage-, heat-, and radiation-free fashion and is therefore free of thermal, electrical, or discharge interferences.

  3. Physics of ionized gases

    CERN Document Server

    Smirnov, Boris M

    2001-01-01

    A comprehensive textbook and reference for the study of the physics of ionized gasesThe intent of this book is to provide deep physical insight into the behavior of gases containing atoms and molecules from which one or more electrons have been ionized. The study of these so-called plasmas begins with an overview of plasmas as they are found in nature and created in the laboratory. This serves as a prelude to a comprehensive study of plasmas, beginning with low temperature and "ideal" plasmas and extending to radiation and particle transport phenomena, the response of plasmas to external fields, and an insightful treatment of plasma waves, plasma instabilities, nonlinear phenomena in plasmas, and the study of plasma interactions with surfaces

  4. A escrita no Ensino Superior

    Directory of Open Access Journals (Sweden)

    Maria Conceição Pillon Christofoli

    2013-01-01

    Full Text Available http://dx.doi.org/10.5902/198464445865 O presente artigo trata de apresentar resultados oriundos de pesquisa realizada no Ensino Superior, enfocando a escrita em contextos universitários. Depoimentos por parte dos acadêmicos evidenciam certa resistência ao ato de escrever, o que acaba muitas vezes distanciando o sujeito da produção de um texto. Assim sendo, mesmo que parciais, os resultados até então analisados dão conta de que: pressuposto 1 – há ruptura da ideia de coerência entre o que pensamos, o que conseguimos escrever, o que entende nosso interlocutor; pressuposto 2 – a autocorreção de textos como exercício de pesquisa é imprescindível para a qualificação da escrita; pressuposto 3 – os diários de aula representam rico instrumento para a qualificação da escrita no Ensino Superior; pressuposto 4 – há necessidade de que o aluno do Ensino Superior escreva variados tipos de escrita, ainda que a universidade cumpra com seu papel, enfatizando a escrita acadêmica; pressuposto 5 – o trabalho com a escrita no Ensino Superior deve enfatizar os componentes básicos da expressão escrita: o código escrito e a composição da escrita. Palavras-chave: Escrita; Ensino Superior; formação de professores.

  5. Depression and ionizing radiation.

    Science.gov (United States)

    Loganovsky, K N; Vasilenko, Z L

    2013-01-01

    The objective of this at issue paper is the analysis of published data in correlation with the results of own research on the potential role of ionizing radiation in the genesis of depressive disorders. Depression is one of the most significant and long-term effect of the atomic bombings, nuclear testing and radiation emergences. The participants of the accident at the Chornobyl nuclear power plant increased prevalence of depression (18.0% and 13.1% in controls) and suicide rates. Depression is mainly observed in the structure of an organic mental disorder against cerebrovascular disease. The clinical pattern is dominated by asthenoadynamic and asthenoapathetic depression. Depressive disorders in radiation emergencies are multifactorial, that is the result of exposure to the complex psychogenic and radiological accident's factors, impact of traditional risk factors, somatic and neurological diseases, genetic predisposition, predisposition, etc. At the same time, exposure to ionizing radiation is a factor in the genesis of depression. This impact can be direct (to the Central Nervous System), and indirectly through the somatic and neurological abnormalities (multiorgan dysfunction) as well as by a variety of pathogenic mechanisms of ionizing radiation on the brain that have been discovered recently. It is strongly necessary analytical clinical and epidemiological studies with verification of depression and evidence-based establishment of the role of radiation and non-radiation risk factors. Loganovskyj K. N., Vasylenko Z. L., 2013.

  6. Ionized Gaseous Nebulae Abundance Determination from the Direct Method

    Science.gov (United States)

    Pérez-Montero, Enrique

    2017-04-01

    This tutorial explains the procedure used to analyze an optical emission-line spectrum produced by a nebula ionized by massive star formation. Particularly, the methodology used to derive physical properties, such as electron density and temperature, and the ionic abundances of the most representative elements whose emission lines are present in the optical spectrum is described. The main focus is on the direct method, which is based on the measurement of the electron temperature to derive the abundances, given that the ionization and thermal equilibrium of the ionized gas is dominated by the metallicity. The ionization correction factors used to obtain total abundances from the abundances of some of their ions are also given. Finally, some strong-line methods to derive abundances are described. Such methods are used when no estimation of the temperature can be derived, but which can be consistent with the direct method if they are empirically calibrated.

  7. Molecular Hydrogen in the Ionized Region of Planetary Nebulae

    CERN Document Server

    Aleman, I

    2004-01-01

    This paper presents an analysis of the concentration of the hydrogen molecule inside the ionized region of planetary nebulae. The equations corresponding to the ionization and chemical equilibria of H, H+, H-, H2, H2+, and H3+ are coupled with the equations of ionization and thermal balance for a photoionized atomic gas. Forty different reactions related to the formation or the destruction of these species are included. The presence of dust is taken into account, since grains act as catalysts for the production of H2, as well as shield the molecules against the stellar ionizing radiation. We analyze the effect of the stellar ionizing continuum, as well as of the gas and grain properties on the calculated H2 mass. It is shown that a significant concentration of H2 can survive inside the ionized region of planetary nebulae, mostly in the inner region of the recombination zone. The total H2 to total hydrogen mass ratio inside the ionized region increases with the central star temperature, and, depending on the P...

  8. Characterization of nonpolar lipids and steroids by using laser-induced acoustic desorption/chemical ionization, atmospheric pressure chemical ionization, and electrospray ionization mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Z; Daiya, S; Kenttämaa, Hilkka I

    Laser-induced acoustic desorption (LIAD) combined with ClMn(H{sub 2}O){sup +} chemical ionization (CI) was tested for the analysis of nonpolar lipids and selected steroids in a Fourier-transform ion cyclotron resonance mass spectrometer (FT-ICR). The nonpolar lipids studied, cholesterol, 5α-cholestane, cholesta-3,5-diene, squalene, and β-carotene, were found to solely form the desired water replacement product (adduct-H{sub 2}O) upon reaction with the ClMn(H{sub 2}O){sup +} ions. The steroids, androsterone, dehydroepiandrosterone (DHEA), estrone, estradiol, and estriol, also form abundant adduct-H{sub 2}O ions, but less abundant adduct-2H{sub 2}O ions were also observed. Neither (+)APCI nor (+)ESI can ionize the saturated hydrocarbon lipid, cholestane. APCI successfully ionizes the unsaturated hydrocarbon lipids to form exclusively the intact protonated analytes. However, it causes extensive fragmentation for cholesterol and the steroids. The worst case is cholesterol that does not produce any stable protonated molecules. On the other hand, ESI cannot ionize any of the hydrocarbon analytes, saturated or unsaturated. However, ESI can be used to protonate the oxygen-containing analytes with substantially less fragmentation than for APCI in all cases except for cholesterol and estrone. In conclusion, LIAD/ClMn(H{sub 2}O){sup +} chemical ionization is superior over APCI and ESI for the mass spectrometric characterization of underivatized nonpolar lipids and steroids.

  9. Polarization and Velocity Dependence of Associative Ionization in Na(3p)+Na(3p) Collisions

    NARCIS (Netherlands)

    Meijer, H.A.J.; Meulen, H.P. van der; Morgenstern, R.

    1987-01-01

    We have excited Na atoms of two counterrunning thermal beams by means of linearly polarized laser light and have investigated associative ionization processes. To this end we measured the total ionization signal as a function of the angle θ between light polarization and the relative collision veloc

  10. Pensamiento Superior y Desarrollo Territorial

    Directory of Open Access Journals (Sweden)

    Víctor Manuel Racancoj Alonzo

    2015-04-01

    Full Text Available Esta reflexión pretende explicar el papel, fundamental, que juega el pensamiento superior, en la formulación y la práctica de modelos de desarrollo territorial local; para que contribuyan de forma sustantiva, en la transformación de las condiciones socioeconómicas adversas que hoy viven comunidades indígenas y rurales de muchos países, como Guatemala, situación que puede resumirse en altos índices de pobreza y desnutrición. Pero, el pensamiento superior, debe ser competencia de la población con pertenencia a lo local, pues si y solo si esta condición existe, se dará validez y viabilidad al desarrollo territorial. Para alcanzar competencias de pensamiento superior, en los espacios locales, se tiene que superar obstáculos en el modelo de universidad, que hoy estamos familiarizados a ver y pensar; modelos que tienen las características de: herencia colonial, disfunción con la problemática económica, cultural, social y política de la sociedad y la negación de los saberes ancestrales.

  11. Superior sulcus tumors (Pancoast tumors).

    Science.gov (United States)

    Marulli, Giuseppe; Battistella, Lucia; Mammana, Marco; Calabrese, Francesca; Rea, Federico

    2016-06-01

    Superior Sulcus Tumors, frequently termed as Pancoast tumors, are a wide range of tumors invading the apical chest wall. Due to its localization in the apex of the lung, with the potential invasion of the lower part of the brachial plexus, first ribs, vertebrae, subclavian vessels or stellate ganglion, the superior sulcus tumors cause characteristic symptoms, like arm or shoulder pain or Horner's syndrome. The management of superior sulcus tumors has dramatically evolved over the past 50 years. Originally deemed universally fatal, in 1956, Shaw and Paulson introduced a new treatment paradigm with combined radiotherapy and surgery ensuring 5-year survival of approximately 30%. During the 1990s, following the need to improve systemic as well as local control, a trimodality approach including induction concurrent chemoradiotherapy followed by surgical resection was introduced, reaching 5-year survival rates up to 44% and becoming the standard of care. Many efforts have been persecuted, also, to obtain higher complete resection rates using appropriate surgical approaches and involving multidisciplinary team including spine surgeon or vascular surgeon. Other potential treatment options are under consideration like prophylactic cranial irradiation or the addition of other chemotherapy agents or biologic agents to the trimodality approach.

  12. Ionization cross section of partially ionized hydrogen plasma

    Energy Technology Data Exchange (ETDEWEB)

    Baimbetov, F B; Kudyshev, Z A [Department of Physics, al - Farabi Kazakh National University, Almaty (Kazakhstan)], E-mail: Bfb77@kazsu.kz, E-mail: Z.Kudyshev@mail.ru

    2008-05-01

    In present work the electron impact ionization cross section is considered. The electron impact ionization cross section is calculated, based on pseudopotential model of interaction between plasma particles which accounts correlation effects. It is calculated with help of two methods: classical and quantum - mechanical (Born approximation). The ionization cross section is compared with corresponding results of other authors and experimental data. It has been shown that it is very important to take into account an influence of the surrounding during consideration of ionization processes.

  13. Ionizing radiation post-curing of objects produced by stereolithography and other methods

    Science.gov (United States)

    Howell, David H.; Eberle, Claude C.; Janke, Christopher J.

    2000-01-01

    An object comprised of a curable material and formed by stereolithography or another three-dimensional prototyping method, in which the object has undergone initial curing, is subjected to post-curing by ionizing radiation, such as an electron beam having a predetermined beam output energy, which is applied in a predetermined dosage and at a predetermined dose rate. The post-cured object exhibits a property profile which is superior to that which existed prior to the ionizing radiation post-curing.

  14. Determination of Trace Technetium-99 in Soil Samples by Isotope Dilution/Negative Thermal Ionization Mass Spectrometry%同位素稀释-负热表面电离质谱法分析土壤样品中的超微量99Tc

    Institute of Scientific and Technical Information of China (English)

    汤磊; 王丽雄; 刘雪梅; 龙开明; 杨通在; 熊宗华; 龚建

    2012-01-01

    As an important long-lived and high-abundance fission product, "Tc dispersed into the environment because of the nuclear test in atmosphere, the nuclear fuel cycle and nuclear medicine. The isotope dilution mass spectrometry (IDMS) technology of measuring 99 Tc using 97Tc as the spike was developed. The chemical separation procedure of Tc is established, and the recovery rate is more than 71% for the overall process. 97Tc (97Tc, 84.77%; 98Tc, 15.03%; "Tc, 0.20%) was prepared by irradiation of natural ruthenium metal, then was calibrated by IDMS with "Tc standard material as the spike. The conventional positive thermal ionization mass spectrometry (TIMS) was inapplicable due to the high ionization potential of 7. 3 eV for technetium, therefore based on MgCl2+Ba(OH)2 as the loading reagent, the negative thermal ionization mass spectrometry of technetium was established, and the ion current indensity of 99TcO-4 (M/z= 163) reached 1. 7 × 10-12 A. Then, 99Tc in the soil samples was quantitatively determined by negative thermal ionization mass spectrometry and isotope dilution method. The combined standard uncertainty is better than 3%.%为了定量测定土壤样品中的超微量99Tc,发展了Tc的放化分离纯化流程和负热电离质谱分析技术,自行制备了97Tc稀释剂.建立了土壤样品中超微量Tc的放化分离流程,全流程Tc化学回收率为71%.采用天然Ru粉在高通量反应堆中辐照,提取并标定了97Tc稀释剂(同位素丰度:97Tc,84.77%;98Tc,15.03%;97Tc,0.20%).由于Tc具有极高的电离电位(7.3 eV),采用热表面电离质谱(TIMS)难以测量,因此研究了Tc的负热电离质谱分析技术(NTIMS).对比研究了4种发射剂,使用MgCl2+Ba(OH)2负离子发射剂,Tc标准样品的99TcO-4 (M/z=163)离子流强度可以达到1.7×10-12 A.采用该定量分析技术对土壤样品进行了99Tc的定量测定,合成标准不确定度好于3%.

  15. NON-EQUILIBRIUM HELIUM IONIZATION IN AN MHD SIMULATION OF THE SOLAR ATMOSPHERE

    Energy Technology Data Exchange (ETDEWEB)

    Golding, Thomas Peter; Carlsson, Mats [Institute of Theoretical Astrophysics, University of Oslo, P.O. Box 1029 Blindern, NO-0315 Oslo (Norway); Leenaarts, Jorrit, E-mail: thomas.golding@astro.uio.no, E-mail: mats.carlsson@astro.uio.no, E-mail: jorrit.leenaarts@astro.su.se [Institute for Solar Physics, Department of Astronomy, Stockholm University, AlbaNova University Centre, SE-106 91 Stockholm (Sweden)

    2016-02-01

    The ionization state of the gas in the dynamic solar chromosphere can depart strongly from the instantaneous statistical equilibrium commonly assumed in numerical modeling. We improve on earlier simulations of the solar atmosphere that only included non-equilibrium hydrogen ionization by performing a 2D radiation-magnetohydrodynamics simulation featuring non-equilibrium ionization of both hydrogen and helium. The simulation includes the effect of hydrogen Lyα and the EUV radiation from the corona on the ionization and heating of the atmosphere. Details on code implementation are given. We obtain helium ion fractions that are far from their equilibrium values. Comparison with models with local thermodynamic equilibrium (LTE) ionization shows that non-equilibrium helium ionization leads to higher temperatures in wavefronts and lower temperatures in the gas between shocks. Assuming LTE ionization results in a thermostat-like behavior with matter accumulating around the temperatures where the LTE ionization fractions change rapidly. Comparison of DEM curves computed from our models shows that non-equilibrium ionization leads to more radiating material in the temperature range 11–18 kK, compared to models with LTE helium ionization. We conclude that non-equilibrium helium ionization is important for the dynamics and thermal structure of the upper chromosphere and transition region. It might also help resolve the problem that intensities of chromospheric lines computed from current models are smaller than those observed.

  16. Multiple ionization in strong fields

    OpenAIRE

    Rudenko, A; Moshammer, R; Schröter, C; Zrost, K.; Feuerstein, B.; de Jesus, V.; Ullrich, J.

    2005-01-01

    Single and multiple ionization of rare gas atoms by 25 and 7 fs intense laser pulses has been studied using a "Reaction Microscope”. For single ionization of He, Ne and Ar in the tunnelling regime, surprising and distinct patterns have been observed in high-resolution low-energy electron spectra. Mechanisms of double and multiple ionization were elucidated and partly identified via recoil-ion momentum distributions and correlated electron spectra. For Ne the highly correlated “instantaneous” ...

  17. Physics of Ionized Gases

    Science.gov (United States)

    Reiss, Howard R.; Smirnov, Boris M.

    2001-03-01

    A comprehensive textbook and reference for the study of the physics of ionized gases The intent of this book is to provide deep physical insight into the behavior of gases containing atoms and molecules from which one or more electrons have been ionized. The study of these so-called plasmas begins with an overview of plasmas as they are found in nature and created in the laboratory. This serves as a prelude to a comprehensive study of plasmas, beginning with low temperature and "ideal" plasmas and extending to radiation and particle transport phenomena, the response of plasmas to external fields, and an insightful treatment of plasma waves, plasma instabilities, nonlinear phenomena in plasmas, and the study of plasma interactions with surfaces. In all cases, the emphasis is on a clear and unified understanding of the basic physics that underlies all plasma phenomena. Thus, there are chapters on plasma behavior from the viewpoint of atomic and molecular physics, as well as on the macroscopic phenomena involved in physical kinetics of plasmas and the transport of radiation and of charged particles within plasmas. With this grounding in the fundamental physics of plasmas, the notoriously difficult subjects of nonlinear phenomena and of instabilities in plasmas are then treated with comprehensive clarity.

  18. Entidades fiscalizadoras superiores y accountability

    OpenAIRE

    Estela Moreno, María

    2016-01-01

    OBJETIVOS DE LA TESIS: El objetivo general del trabajo es establecer el nivel de eficacia de las Entidades Fiscalizadoras Superiores (EFS) como agencia asignada y herramienta de accountability horizontal, a través de la valoración de su diseño institucional y de la calidad de sus productos finales, los informes de auditoría, estableciéndose los siguientes objetivos específicos: 1. Relevar las nociones de accountability, actualizando el Estado del Arte de la cuestión. 2. Analizar la ...

  19. The sentence superiority effect revisited.

    Science.gov (United States)

    Snell, Joshua; Grainger, Jonathan

    2017-11-01

    A sentence superiority effect was investigated using post-cued word-in-sequence identification with the rapid parallel visual presentation (RPVP) of four horizontally aligned words. The four words were presented for 200ms followed by a post-mask and cue for partial report. They could form a grammatically correct sentence or were formed of the same words in a scrambled agrammatical sequence. Word identification was higher in the syntactically correct sequences, and crucially, this sentence superiority effect did not vary as a function of the target's position in the sequence. Cloze probability measures for words at the final, arguably most predictable position, revealed overall low values that did not interact with the effects of sentence context, suggesting that these effects were not driven by word predictability. The results point to a level of parallel processing across multiple words that enables rapid extraction of their syntactic categories. These generate a sentence-level representation that constrains the recognition process for individual words, thus facilitating parallel word processing when the sequence is grammatically sound. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Multiphoton ionization of Uracil

    Science.gov (United States)

    Prieto, Eladio; Martinez, Denhi; Guerrero, Alfonso; Alvarez, Ignacio; Cisneros, Carmen

    2016-05-01

    Multiphoton ionization and dissociation of Uracil using a Reflectron time of flight spectrometer was performed along with radiation from the second harmonic of a Nd:YAG laser. Uracil is one of the four nitrogen bases that belong to RNA. The last years special interest has been concentrated on the study of the effects under UV radiation in nucleic acids1 and also in the role that this molecule could have played in the origin and development of life on our planet.2 The MPI mass spectra show that the presence and intensity of the resulting ions strongly depend on the density power. The identification of the ions in the mass spectra is presented. The results are compared with those obtained in other laboratories under different experimental conditions and some of them show partial agreement.3 The present work was supported by CONACYT-Mexico Grant 165410 and DGAPA UNAM Grant IN101215 and IN102613.

  1. Applications of ionizing radiations

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2014-07-01

    Developments in standard applications and brand new nuclear technologies, with high impact on the future of the agriculture, medicine, industry and the environmental preservation. The Radiation Technology Center (CTR) mission is to apply the radiation and radioisotope technologies in Industry, Health, Agriculture, and Environmental Protection, expanding the scientific knowledge, improving human power resources, transferring technology, generating products and offering services for the Brazilian society. The CTR main R and D activities are in consonance with the IPEN Director Plan (2011-2013) and the Applications of Ionizing Radiation Program, with four subprograms: Irradiation of Food and Agricultural Products; Radiation and Radioisotopes Applications in Industry and Environment; Radioactive Sources and Radiation Applications in Human Health; and Radioactive Facilities and Equipment for the Applications of Nuclear Techniques.

  2. 78 FR 21116 - Superior Supplier Incentive Program

    Science.gov (United States)

    2013-04-09

    ... Department of the Navy Superior Supplier Incentive Program AGENCY: Department of the Navy, DoD. ACTION... policy that will establish a Superior Supplier Incentive Program (SSIP). Under the SSIP, contractors that..., performance, quality, and business relations would be granted Superior Supplier Status (SSS). Contractors...

  3. superior en México

    Directory of Open Access Journals (Sweden)

    César Mureddu Torres

    2008-01-01

    Full Text Available El presente artículo desarrolla algunos de los retos que ha traído consigo el acceso a la información existente en la red de Internet y lo que ello supone. Se abordan principalmente las consecuencias de la presencia actual de una sociedad llamada del conocimiento, si se mantiene la confusión entre conocimiento e información. Por ello, la sola gestión de la información no puede ser tomada como definitoria respecto a la función de educación superior confiada a las universidades. Hacerlo sería cometer un error aún más grave que la confusión teórica entre los términos mencionados.

  4. Monte-Carlo approach to calculate the ionization of warm dense matter within particle-in-cell simulations

    CERN Document Server

    Wu, D; Yu, W; Fritzsche, S

    2016-01-01

    A physical model based on Monte-Carlo approach is proposed to calculate the ionization dynamics of warm dense matters within particle-in-cell simulations, where impact ionization, electron-ion recombination and ionization potential depression (IPD) by surrounding plasmas are taken into consideration self-consistently. When compared with other models, which are applied in the literature for plasmas near thermal equilibrium, the temporal relaxation of ionizations can also be simulated by the proposed model with the final thermal equilibrium determined by the competition between impact ionization and its inverse process, i.e., electron-ion recombination. Our model is general and can be applied for both single elements and alloys with quite different compositions. The proposed model is implemented into a particle-in-cell (PIC) simulation code, and the average ionization degree of bulk aluminium varying with temperature is calculated, showing good agreement with the data provided by FLYCHK code.

  5. Ionization Chamber Measures Extreme Ultraviolet

    Science.gov (United States)

    Carlson, Robert W.

    1987-01-01

    Ionization chamber operates in nearly total photon absorption as stable, self-calibrating detector of ionizing extreme ultraviolet radiation. Working gas of instrument is neon; photoionization properties well known and readily applicable to absolute measurements. Designed for measurements of solar ultraviolet flux aboard sounding rocket, instrument used on Earth to measure ultraviolet radiation in vacuum systems. Ionization chamber collects positive neon ions and electrons produced by irradiation of neon gas by ultraviolet photons. Approximately one ion produced by each photon; consequently, photoionization current nearly proportional to photon flux.

  6. Photoionization effects in ionization fronts

    Energy Technology Data Exchange (ETDEWEB)

    Arrayas, Manuel [Departamento de Electromagnetismo, Universidad Rey Juan Carlos, Tulipan s/n, 28933 Mostoles, Madrid (Spain); Fontelos, Marco A [Departamento de Matematicas, Instituto de Matematicas y Fisica Fundamental, Consejo Superior de Investigaciones CientIficas, C/Serrano 123, 28006 Madrid (Spain); Trueba, Jose L [Departamento de Electromagnetismo, Universidad Rey Juan Carlos, Tulipan s/n, 28933 Mostoles, Madrid (Spain)

    2006-12-21

    In this paper we study the effects of photoionization processes on the propagation of both negative and positive ionization fronts in streamer discharge. We show that negative fronts accelerate in the presence of photoionization events. The appearance and propagation of positive ionization fronts travelling with constant velocity is explained as the result of the combined effects of photoionization and electron diffusion. The photoionization range plays an important role in the selection of the velocity of the ionization front as we show in this work.

  7. Escuela Superior de Palos Verdes

    Directory of Open Access Journals (Sweden)

    Neutra, Richard J.

    1965-02-01

    Full Text Available Before initiating the building operations for the «Palos Verdes» School, the site was divided into two large horizontal surfaces, at different levels. The lower one served to accommodate the playing fields, a car park, the physical training building, and shop and ancillary buildings. On the higher of these two surfaces, and to the West of the access road, there is a car park and also the building and plot of ground devoted to agricultural technology, as well as the literary studies and general purpose buildings. As a complement to these, there is a series of blocks, arranged in parallel rows, which house the administrative offices, the art school, the craft's school, the general classrooms, and those devoted to higher education. The fascinating aspect of this school is the outstanding penetration of the architect's mind into the essential function of the project. Its most evident merit is the sense of comradeship and harmony that permeates the whole architectural manifold.Antes de construir el complejo escolar «Palos Verdes» se comenzó por crear, en el terreno, dos grandes mesetas a niveles diferentes. Sobre el inferior se organizaron: los campos de juegos, de deportes, un aparcamiento, el edificio para educación física y los destinados a tiendas y servicios. Sobre la meseta superior, al oeste de la vía de acceso, se dispuso un aparcamiento y el edificio y campo para adiestramiento agrícola; al este, otro aparcamiento, el edificio dedicado a materias literarias, y el destinado a usos múltiples. Completan las instalaciones de la escuela una serie de bloques paralelos: la administración, la escuela de arte, las clases de trabajos manuales, las aulas de enseñanzas generales, y las de los cursos superiores. Lo fascinante de este complejo escolar es la perfecta y magistral compenetración del arquitecto con el tema proyectado, y su mayor mérito, la sensación de cordialidad y armonía con el ambiente.

  8. Ionization Mechanism of the Ambient Pressure Pyroelectric Ion Source (APPIS) and Its Applications to Chemical Nerve Agent Detection

    OpenAIRE

    Neidholdt, Evan L.; Beauchamp, J. L.

    2009-01-01

    We present studies of the ionization mechanism operative in the ambient pressure pyroelectric ionization source (APPIS), along with applications that include detection of simulants for chemical nerve agents. It is found that ionization by APPIS occurs in the gas-phase. As the crystal is thermally cycled over a narrow temperature range, electrical discharges near the surface of the crystal produce energetic species which, through reactions with atmospheric molecules, result in reactant ions su...

  9. Ionization of impurities in silicon

    Science.gov (United States)

    Kuźmicz, Wiesław

    1986-12-01

    A model for calculation of the percentage of ionized dopant atoms as a function of the doping concentration and temperature is proposed. The results are compared with experiment. Analytical approximations that facilitate practical applications of the model are given.

  10. Strong Ionization in carbon Nanowires

    CERN Document Server

    Kaymak, Vural; Shlyaptsev, Vyacheslav N; Rocca, Jorge J

    2015-01-01

    Surfaces covered with nanostructures, such as nanowire arrays, have shown to facilitate a significantly higher absorption of laser energy as compared to flat surfaces. Due to the efficient coupling of the laser energy, highly energetic electrons are produced, which in turn can emit intense ultrafast X-ray pulses. In the present work we use full three dimensional PIC simulations to analyze the behavior of arrays of carbon nanowires $400 nm$ in diameter, irradiated by a $\\lambda_0 = 400 nm$ laser pulse of $60 fs$ duration at FWHM and a vector potential of $a_0 = 18$. We analyze the ionization dynamics of the nanowires. We investigate the difference of the ionization strength and structure between linearly and circularly polarized laser beam. The nanowires are found to be fully ionized after about 30 laser cycles. Circularly polarized light reveals a slightly stronger ionization effect.

  11. Resonance Ionization Laser Ion Sources

    CERN Document Server

    Marsh, B

    2013-01-01

    The application of the technique of laser resonance ionization to the production of singly charged ions at radioactive ion beam facilities is discussed. The ability to combine high efficiency and element selectivity makes a resonance ionization laser ion source (RILIS) an important component of many radioactive ion beam facilities. At CERN, for example, the RILIS is the most commonly used ion source of the ISOLDE facility, with a yearly operating time of up to 3000 hours. For some isotopes the RILIS can also be used as a fast and sensitive laser spectroscopy tool, provided that the spectral resolution is sufficiently high to reveal the influence of nuclear structure on the atomic spectra. This enables the study of nuclear properties of isotopes with production rates even lower than one ion per second and, in some cases, enables isomer selective ionization. The solutions available for the implementation of resonance laser ionization at radioactive ion beam facilities are summarized. Aspects such as the laser r...

  12. Are cosmic rays effective for ionization of protoplanetary disks?

    Science.gov (United States)

    Dolginov, Arkady Z.; Stepinski, Tomasz F.

    1994-01-01

    The principal uncertainty in studying the magnetic properties of protoplanetary disks concerns the ionization levels of the disk's gas. The low gas temperature precludes thermal ionization, leaving cosmic rays as the dominant source of ionization. It has been shown that the resulting electrical conductivity is just high enough for a MHD dynamo to produce contemporaneously a magnetic field in most of the extended parts of a turbulent protoplanetary disk. Here we argue that the effectiveness of cosmic rays to ionize the bulk of the gas is impaired by the influence of the generated magnetic field on the propagation of cosmic rays within a disk. Cosmic rays scatter on magnetic inhomogeneities, and, as a result, their penetration depth decreases to only a fraction of the disk half-thickness, resulting in a severe depletion of free charge from the midplane regions of a disk. That, in turn, undercuts the dynamo mechanism, so extended parts of the disk are free from a dynamically significant magnetic field. We also point out that any additional, even small, in situ source of ionization, such as radioactive Al-26, may again make a dynamo a viable regeneration process capable of producing a dynamically important magnetic field.

  13. Sobredentadura total superior implantosoportada Superior total overdenture on implants

    Directory of Open Access Journals (Sweden)

    Luis Orlando Rodríguez García

    2010-06-01

    Full Text Available Se presenta un caso de un paciente desdentado total superior, rehabilitado en la consulta de implantología de la Clínica "Pedro Ortiz" del municipio Habana del Este en Ciudad de La Habana, Cuba, en el año 2009, mediante prótesis sobre implantes osteointegrados, técnica que se ha incorporado a la práctica estomatológica en Cuba como alternativa al tratamiento convencional en los pacientes desdentados totales. Se siguió un protocolo que comprendió una fase quirúrgica, procedimiento con o sin realización de colgajo y carga precoz o inmediata. Se presenta un paciente masculino de 56 años de edad, que acudió a la consulta multidisciplinaria, preocupado, porque se le habían elaborado tres prótesis en los últimos dos años y ninguna reunía los requisitos de retención que él necesitaba para sentirse seguro y cómodo con las mismas. El resultado final fue la satisfacción total del paciente, con el mejoramiento de la calidad estética y funcional.This is the case of a total maxilla edentulous patient seen in consultation of the "Pedro Ortíz" Clinic Implant of Habana del Este municipality in 2009 and con rehabilitation by prosthesis over osteointegration implants added to stomatology practice in Cuba as an alternative to conventional treatment in patients totally edentulous. We follow a protocol including a surgery or surgical phase, technique without or with flap creation and early or immediate load. This is a male patient aged 56 came to our multidisciplinary consultation worried because he had three prostheses in last two years and any fulfilled the requirements of retention to feel safe and comfortable with prostheses. The final result was the total satisfaction of rehabilitated patient improving its aesthetic and functional quality.

  14. Thermal and Nonthermal Radio Galaxies

    CERN Document Server

    Antonucci, Robert

    2011-01-01

    Radio galaxies were discovered and mapped in the 1950s. The optical spectra showed little or no nuclear continuum light. Some also revealed powerful high ionization emission lines, while others showed at most weak low-ionization emission lines. Quasars were found in the 1960s, and their spectra were dominated by powerful continuum radiation which was subsequently identified with optically thick thermal radiation from copious accretion flows, as well as high ionization narrow emission lines, and powerful broad permitted lines. By the 1980s, data from optical polarization and statistics of the radio properties required that many radio galaxies contain hidden quasar nuclei, hidden from the line of sight by dusty, roughly toroidal gas distributions. The radio galaxies with hidden quasars are referred to as "thermal." Do all radio galaxies have powerful hidden quasars? We now know the answer using arguments based on radio, infrared, optical and X-ray properties. Near the top of the radio luminosity function, for F...

  15. Responsive copolymer films obtained by ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Burillo, G.; Bucio, E. [Departamento de Quimica de Radiaciones y Radioquimica, Instituto de Ciencias Nucleares, UNAM, Circuito Exterior, Ciudad Universitaria, Mexico 04510, D. F. (Mexico)], e-mail: burillo@nucleares.unam.mx

    2009-07-01

    The graft copolymerization of ph and/or thermo sensitive monomers onto polymeric films can be achieved by different radiation methods which have great advantages compared to conventional methods. Their ph and thermal sensitivity properties, as well as LCST and critical ph point, have been studied by DSC, UV, FTIR, water contact angle and swelling. Graft copolymerization can be carried out by pre-irradiation oxidative and direct methods, using {sup 6}0Co gamma radiation or a Van de Graaff electron beam accelerator. The influence of synthesis conditions, such as pre-irradiation or radiation doses, dose rate, reaction time, monomer concentration, and reaction temperature are being studied. Advances in the field of responsive polymeric systems synthesized by ionizing radiation, their applications and promising future research on radiation graft polymerization and crosslinking will be discussed. (Author)

  16. Resonance ionization scheme development for europium

    CERN Document Server

    Chrysalidis, K; Fedosseev, V N; Marsh, B A; Naubereit, P; Rothe, S; Seiffert, C; Kron, T; Wendt, K

    2017-01-01

    Odd-parity autoionizing states of europium have been investigated by resonance ionization spectroscopy via two-step, two-resonance excitations. The aim of this work was to establish ionization schemes specifically suited for europium ion beam production using the ISOLDE Resonance Ionization Laser Ion Source (RILIS). 13 new RILIS-compatible ionization schemes are proposed. The scheme development was the first application of the Photo Ionization Spectroscopy Apparatus (PISA) which has recently been integrated into the RILIS setup.

  17. Resonance ionization scheme development for europium

    Energy Technology Data Exchange (ETDEWEB)

    Chrysalidis, K., E-mail: katerina.chrysalidis@cern.ch; Goodacre, T. Day; Fedosseev, V. N.; Marsh, B. A. [CERN (Switzerland); Naubereit, P. [Johannes Gutenberg-Universität, Institiut für Physik (Germany); Rothe, S.; Seiffert, C. [CERN (Switzerland); Kron, T.; Wendt, K. [Johannes Gutenberg-Universität, Institiut für Physik (Germany)

    2017-11-15

    Odd-parity autoionizing states of europium have been investigated by resonance ionization spectroscopy via two-step, two-resonance excitations. The aim of this work was to establish ionization schemes specifically suited for europium ion beam production using the ISOLDE Resonance Ionization Laser Ion Source (RILIS). 13 new RILIS-compatible ionization schemes are proposed. The scheme development was the first application of the Photo Ionization Spectroscopy Apparatus (PISA) which has recently been integrated into the RILIS setup.

  18. The Application of Resonance-Enhanced Multiphoton Ionization Technique in Gas Chromatography Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Adan Li

    2014-01-01

    Full Text Available Gas chromatography resonance-enhanced multiphoton ionization time-of-flight mass spectrometry (GC/REMPI-TOFMS using a nanosecond laser has been applied to analyze the 16 polycyclic aromatic hydrocarbons (PAHs. The excited-state lifetime, absorption characters, and energy of electronic states of the 16 PAHs were investigated to optimize the ionization yield. A river water sample pretreated by means of solid phase extraction was analyzed to evaluate the performance of the analytical instrument. The results suggested that REMPI is superior to electron impact ionization method for soft ionization and suppresses the background signal due to aliphatic hydrocarbons. Thus, GC/REMPI-TOFMS is a more reliable method for the determination of PAHs present in the environment.

  19. Insertion of an electron beam ionizer in a quadrupole spectrometer for secondary neutral mass analysis

    CERN Document Server

    Ameziane, O; Serrano, J; Guzman, B; Aguilar, M A

    2003-01-01

    An insertable electron beam ionizer into a quadrupole-based secondary ion mass spectrometer instrument has been designed and installed to analyze sputtered neutrals. The optimum design conditions of the ionizer have been obtained by modeling various configurations of the system using a simulation program developed by us. The program has allowed us to compute the potentials and ion trajectories inside the system to test the performance of the ion optics design. We have investigated the advantages of using a large ionization volume with low electron current to minimize the space charge effect in the ionizer, as this is the major problem in this type of instrument. In addition, we have used the simulations to obtain' all electrodes voltages which provide an efficient suppression of residual gas and secondary ions. A good useful yield was obtained, even with low electron densities, thanks to the high geometrical acceptance of the ionizer and its large active volume. This configuration implies less thermal radiati...

  20. Ambient ionization mass spectrometry: A tutorial

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Min-Zong; Cheng, Sy-Chi; Cho, Yi-Tzu [Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan (China); Shiea, Jentaie, E-mail: jetea@fac.nsysu.edu.tw [Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan (China); Cancer Center, Kaohsiung Medical University, Kaohsiung, Taiwan (China)

    2011-09-19

    Highlights: {yields} Ambient ionization technique allows the direct analysis of sample surfaces with little or no sample pretreatment. {yields} We sort ambient ionization techniques into three main analytical strategies, direct ionization, direct desorption/ionization, and two-step ionization. {yields} The underlying principles of operation, ionization processes, detecting mass ranges, sensitivity, and representative applications of these techniques are described and compared. - Abstract: Ambient ionization is a set of mass spectrometric ionization techniques performed under ambient conditions that allows the direct analysis of sample surfaces with little or no sample pretreatment. Using combinations of different types of sample introduction systems and ionization methods, several novel techniques have been developed over the last few years with many applications (e.g., food safety screening; detection of pharmaceuticals and drug abuse; monitoring of environmental pollutants; detection of explosives for antiterrorism and forensics; characterization of biological compounds for proteomics and metabolomics; molecular imaging analysis; and monitoring chemical and biochemical reactions). Electrospray ionization and atmospheric pressure chemical ionization are the two main ionization principles most commonly used in ambient ionization mass spectrometry. This tutorial paper provides a review of the publications related to ambient ionization techniques. We describe and compare the underlying principles of operation, ionization processes, detecting mass ranges, sensitivity, and representative applications of these techniques.

  1. Paso superior en una ladera

    Directory of Open Access Journals (Sweden)

    Bender, O.

    1965-07-01

    Full Text Available The Redwood highway, through the Californian forest, runs on a viaduct, as it crosses a mountain slope of about 45° inclination. The firm ground is fairly deep, and as an additional constructional difficulty, it was necessary to respect the natural beauty of the countryside. A structure of portal frames were built, forming a number of short spans. These spans were bridged with metal girders, on which a 19 m wide deck was placed. The columns are hollow and have a transversal cross beam, to join each pair. There was difficulty in excavating the foundations for the columns, as it was necessary to dig through the soft top soil, and also prevent this soil from hurting the trunks of the forest trees. Another significant difficulty in the construction of this viaduct was the access to the working site, since there were no suitable platforms from which to operate the appropriate machinery. This made it necessary to do a lot of the work by manual operation. As one of the edges of the deck is very close to the mountain side, a supporting beam was erected on this side. It was made of concrete, on metal piles. The formwork for the deck structure was placed on the concrete stems of the supporting piles.La autopista denominada Redwood (California salva, con un paso superior, la ladera de un bosque cuya pendiente es del 1/1. El terreno firme se halla a bastante profundidad, añadiéndose, a los naturales problemas de la construcción, el imperativo de respetar la belleza agreste del paraje. La solución adoptada consiste en una estructura porticada, con varios tramos de pequeñas luces, salvados con vigas metálicas, sobre los que se coloca la losa del tablero, de 19 m de anchura total. Los soportes están constituidos por pórticos de dos montantes huecos (con bases de hormigón en masa por debajo del suelo, hasta el firme coronados por un cabezal. La perforación de pozos para el hormigonado de los montantes presentaba la dificultad de atravesar el terreno

  2. Free electron degeneracy effects on collisional excitation, ionization, de-excitation and three-body recombination

    Science.gov (United States)

    Tallents, G. J.

    2016-09-01

    Collisional-radiative models enable average ionization and ionization populations, plus the rates of absorption and emission of radiation to be calculated for plasmas not in thermal equilbrium. At high densities and low temperatures, electrons may have a high occupancy of the free electron quantum states and evaluations of rate coefficients need to take into account the free electron degeneracy. We demonstrate that electron degeneracy can reduce collisional rate coefficients by orders-of-magnitude from values calculated neglecting degeneracy. We show that assumptions regarding the collisional differential cross-section can alter collisional ionization and recombination rate coefficients by a further factor two under conditions relevant to inertial fusion.

  3. Ionization Collection in Detectors of the Cryogenic Dark Matter Search

    Energy Technology Data Exchange (ETDEWEB)

    Phipps, Arran T.J. [Univ. of California, Berkeley, CA (United States)

    2016-01-01

    Determining the composition of dark matter is at the forefront of modern scientific research. There is compelling evidence for the existence of vast quantities of dark matter throughout the universe, however it has so-far eluded all direct detection efforts and its identity remains a mystery. Weakly interacting massive particles (WIMPs) are a favored dark matter candidate and have been the primary focus of direct detection for several decades. The Cryogenic Dark Matter Search (CDMS) has developed the Z-dependent Ionization and Phonon (ZIP) detector to search for such particles. Typically made from germanium, these detectors are capable of distinguishing between electromagnetic background and a putative WIMP signal through the simultaneous measurement of ionization and phonons produced by scattering events. CDMS has operated several arrays of these detectors at the Soudan Underground Laboratory (Soudan, MN, USA) resulting in many competitive (often world-leading) WIMP exclusion limits. This dissertation focuses on ionization collection in these detectors under the sub-Kelvin, low electric field, and high crystal purity conditions unique to CDMS. The design and performance of a fully cryogenic HEMT-based amplifier capable of achieving the SuperCDMS SNOLAB ionization energy resolution goal of 100 eVee is presented. The experimental apparatus which has been used to record electron and hole properties under CDMS conditions is described. Measurements of charge transport, trapping, and impact ionization as a function of electric field in two CDMS detectors are shown, and the ionization collection efficiency is determined. The data is used to predict the error in the nuclear recoil energy scale under both CDMSlite and iZIP operating modes. A two species, two state model is developed to describe how ionization collection and space charge generation in CDMS detectors are controlled by the presence of “overcharged” D- donor and A+ acceptor impurity states. The thermal

  4. Pseudodisplacements of superior vena cava catheter in the persistent left superior vena cava

    Energy Technology Data Exchange (ETDEWEB)

    Jantsch, H.; Draxler, V.; Muhar, U.; Schlemmer, M.; Waneck, R.

    1983-01-01

    Pseudodisplacement of a left sided superior vena cava catheter in a persistent superior vena cava may be expected in adults in 0,37% and in a group of children with congenital heart disease in 2,5%. Embryology, anatomy and clinical implications is discussed on the basis of our own cases. The vena cava superior sinistra persitents is depending on a sufficient calibre a suitable vessel for a superior cava catheter.

  5. Atomic Ionization by Electron Impact

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The field of atomic ionization by electron impact is several decades old. In that period of time, significant progress has been made in several aspects of the problem and we have learned a lot about ionizing collisions as a result of this work. Over the years, both the experiments and theories have improved dramatically. Experiments are now able to measure absolute triple differential cross sections for both in-plane or out-of-plane geometries. Theories have been getting better and better at including all the 3-body interactions in the wavefunction for the system. However, during the history of the field, experiment has been ahead of theory and it is just very recently that theory has started to catch up. In this paper, we will show that theory is now able to accurately predict the results of electron impact ionization of hydrogen for intermediate and higher energies.

  6. Theory of dissociative tunneling ionization

    CERN Document Server

    Svensmark, Jens; Madsen, Lars Bojer

    2016-01-01

    We present a theoretical study of the dissociative tunneling ionization process. Analytic expressions for the nuclear kinetic energy distribution of the ionization rates are derived. A particularly simple expression for the spectrum is found by using the Born-Oppenheimer (BO) approximation in conjunction with the reflection principle. These spectra are compared to exact non-BO ab initio spectra obtained through model calculations with a quantum mechanical treatment of both the electronic and nuclear degrees freedom. In the regime where the BO approximation is applicable imaging of the BO nuclear wave function is demonstrated to be possible through reverse use of the reflection principle, when accounting appropriately for the electronic ionization rate. A qualitative difference between the exact and BO wave functions in the asymptotic region of large electronic distances is shown. Additionally the behavior of the wave function across the turning line is seen to be reminiscent of light refraction. For weak fiel...

  7. Ionizing radiation injuries and illnesses.

    Science.gov (United States)

    Christensen, Doran M; Iddins, Carol J; Sugarman, Stephen L

    2014-02-01

    Although the spectrum of information related to diagnosis and management of radiation injuries and illnesses is vast and as radiation contamination incidents are rare, most emergency practitioners have had little to no practical experience with such cases. Exposures to ionizing radiation and internal contamination with radioactive materials can cause significant tissue damage and conditions. Emergency practitioners unaware of ionizing radiation as the cause of a condition may miss the diagnosis of radiation-induced injury or illness. This article reviews the pertinent terms, physics, radiobiology, and medical management of radiation injuries and illnesses that may confront the emergency practitioner. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Ionization chambers for LET determination

    DEFF Research Database (Denmark)

    Kaiser, Franz-Joachim; Bassler, Niels; Tölli, Heikki

    2010-01-01

    resolution and high sensitivity are necessary. For exact dosimetry which is done using ionization chambers (ICs), the recombination taking place in the IC has to be known. Up to now, recombination is corrected phenomenologically and more practical approaches are currently used. Nevertheless, Jaff´e's theory...... of columnar recombination was designed to model the detector efficiency of an ionization chamber. Here, we have shown that despite the approximations and simplification made, the theory is correct for the LETs typically found in clinical radiotherapy employing particles from protons to carbon ions...

  9. Radiative feedback from ionized gas

    CERN Document Server

    Glover, S C O

    2007-01-01

    H2 formation in metal-free gas occurs via the intermediate H- or H2+ ions. Destruction of these ions by photodissociation therefore serves to suppress H2 formation. In this paper, I highlight the fact that several processes that occur in ionized primordial gas produce photons energetic enough to photodissociate H- or H2+ and outline how to compute the photodissociation rates produced by a particular distribution of ionized gas. I also show that there are circumstances of interest, such as during the growth of HII regions around the first stars, in which this previously overlooked form of radiative feedback is of considerable importance.

  10. Superiority in value and the repugnant conclusion

    DEFF Research Database (Denmark)

    Jensen, Karsten Klint

    2007-01-01

    James Griffin has considered a weak form of superiority in value a possible remedy to the Repugnant Conclusion. In this paper, I demonstrate that, in a context where value is additive, this weaker form collapses into a stronger form of superiority. And in a context where value is non-additive, weak...... superiority does not amount to a radical value difference at all. I then spell out the consequences of these results for different interpretations of Griffin's suggestion regarding population ethics. None of them comes out very successful, but perhaps they nevertheless retain some interest....

  11. Field Ionization detection of supersonic helium atom beams

    Science.gov (United States)

    Doak, R. B.

    2003-10-01

    Field ionization detectors (FID) may offer near-unity detection efficiency and nanoscale spatial resolution. To date, FID detection of molecular beams has been limited to effusive beams of broad Maxwellian velocity distributions. We report FID measurements on monoenergetic helium beams, including intensity measurements and time-of-flight measurements. The FID tips were carefully prepared and characterized in a field ionization microscope prior to use. With the supersonic helium beam we find a much smaller effective detection area ( 50 sq. nm) than was reported in the effusive helium beam experiments ( 200,000 sq. nm). This suggests that the FID ionization yield depends strongly on energy loss by the impinging atom during its initial collision with the FID surface: Our thermal energy, monoenergetic helium beam atoms likely lose little or no energy upon scattering from the clean tungsten FID surface, allowing the scattered atoms to escape the FID polarization field and therby reducing the ionization yield. To improve signal levels, inelastic scattering might be enhanced by use of lower beam velocities (present in the tails of a Maxwellian) or by adsorbing an overlayer on the FID tip (present at cryogenic tip temperatures). These factors likely explain the higher detection yields measured in the effusive beam experiments.

  12. A boron-coated ionization chamber for ultra-cold neutron detection

    Energy Technology Data Exchange (ETDEWEB)

    Salvat, D.J., E-mail: dsalvat@indiana.edu [Indiana University Center for Exploration of Energy and Matter, Bloomington, IN 47408 (United States); Morris, C.L.; Wang, Z. [Los Alamos National Laboratory, Los Alamos, NM 87544 (United States); Adamek, E.R. [Indiana University Center for Exploration of Energy and Matter, Bloomington, IN 47408 (United States); Bacon, J. [Los Alamos National Laboratory, Los Alamos, NM 87544 (United States); Hickerson, K.P. [California Institute of Technology, Pasadena, CA 91125 (United States); Hoagland, J.; Holley, A.T. [North Carolina State University, Raleigh, NC 27695 (United States); Liu, C.-Y. [Indiana University Center for Exploration of Energy and Matter, Bloomington, IN 47408 (United States); Makela, M.; Ramsey, J. [Los Alamos National Laboratory, Los Alamos, NM 87544 (United States); Reid, A. [North Carolina State University, Raleigh, NC 27695 (United States); Rios, R. [Idaho State University, Pocatello, ID 83209 (United States); Saunders, A.; Sjue, S.K.L. [Los Alamos National Laboratory, Los Alamos, NM 87544 (United States); VornDick, B.; Young, A.R. [North Carolina State University, Raleigh, NC 27695 (United States)

    2012-11-01

    The design and performance of a boron-coated ionization chamber for the detection of ultra-cold neutrons (UCN) are presented. We detect UCN from the solid deuterium-based UCN source at the Los Alamos Neutron Science Center. Our results indicate comparable efficiency to {sup 3}He ionization chambers and proportional counters currently used at the UCN source. In addition, the ion chamber is used to detect thermal neutrons; a comparison of the thermal neutron and UCN pulse-height spectra indicates that UCN mostly capture near the layer surface.

  13. Ionization Cooling for Muon Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Alexahin, Y. [Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States); Neuffer, D. [Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States); Prebys, E. [Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States)

    2014-09-18

    Possible application for muon experiments such as mu2e is discussed of the initial part of the ionization cooling channel originally developed for muon collider. It is shown that with the FNAL Booster as the proton driver the mu2e sensitivity can be increased by two orders of magnitude compared to the presently considered experiment.

  14. Ionization Cooling for Muon Experiments

    OpenAIRE

    Alexahin, Y.; D. Neuffer; Prebys, E.

    2014-01-01

    Possible application for muon experiments such as mu2e is discussed of the initial part of the ionization cooling channel originally developed for muon collider. It is shown that with the FNAL Booster as the proton driver the mu2e sensitivity can be increased by two orders of magnitude compared to the presently considered experiment.

  15. Electronic measurements of ionization currents

    Energy Technology Data Exchange (ETDEWEB)

    Hutyra, F.; Knapp, K.; Gregor, J. (Tesla, Premysleni (Czechoslovakia). Vyzkumny Ustav Pristroju Jaderne Techniky)

    1982-02-01

    Measurements are discussed of very low currents from ionization chambers. The currents range between 10/sup -15/ and 10/sup -9/ A. Two methods are discussed. A description is given of a dynamic and a semiconductor electrometers. Both meters are parts of dosimetric instruments for monitoring the dose rate (NB 9201) and the neutron-gamma mixed radiation dose rate (NDK 601).

  16. Resonance ionization spectroscopy in dysprosium

    Energy Technology Data Exchange (ETDEWEB)

    Studer, D., E-mail: dstuder@uni-mainz.de; Dyrauf, P.; Naubereit, P.; Heinke, R.; Wendt, K. [Johannes Gutenberg-Universität Mainz, Institut für Physik (Germany)

    2017-11-15

    We report on resonance ionization spectroscopy (RIS) of high-lying energy levels in dysprosium. We developed efficient excitation schemes and re-determined the first ionization potential (IP) via analysis of Rydberg convergences. For this purpose both two- and three-step excitation ladders were investigated. An overall ionization efficiency of 25(4) % could be demonstrated in the RISIKO mass separator of Mainz University, using a three-step resonance ionization scheme. Moreover, an extensive analysis of the even-parity 6sns- and 6snd-Rydberg-series convergences, measured via two-step excitation was performed. To account for strong perturbations in the observed s-series, the approach of multichannel quantum defect theory (MQDT) was applied. Considering all individual series limits we extracted an IP-value of 47901.76(5) cm{sup −1}, which agrees with the current literature value of 47901.7(6) cm{sup −1}, but is one order of magnitude more precise.

  17. Identifying Ionized Regions in Noisy Redshifted 21 cm Data Sets

    CERN Document Server

    Malloy, Matthew

    2012-01-01

    One of the most promising approaches for studying reionization is to use the redshifted 21 cm line. Early generations of redshifted 21 cm surveys will not, however, have the sensitivity to make detailed maps of the reionization process, and will instead focus on statistical measurements. Here we show that it may nonetheless be possible to {\\em directly identify ionized regions} in upcoming data sets by applying suitable filters to the noisy data. The locations of prominent minima in the filtered data correspond well with the positions of ionized regions. In particular, we corrupt semi-numeric simulations of the redshifted 21 cm signal during reionization with thermal noise at the level expected for a 500 antenna tile version of the Murchison Widefield Array (MWA), and mimic the degrading effects of foreground cleaning. Using a matched filter technique, we find that the MWA should be able to directly identify ionized regions despite the large thermal noise. In a plausible fiducial model in which ~20% of the vo...

  18. Millian superiorities and the repugnant conclusion

    DEFF Research Database (Denmark)

    Jensen, Karsten Klint

    2008-01-01

    James Griffin has considered a form of superiority in value that is weaker than lexical priority as a possible remedy to the Repugnant Conclusion. In this article, I demonstrate that, in a context where value is additive, this weaker form collapses into the stronger form of superiority. And in a ......James Griffin has considered a form of superiority in value that is weaker than lexical priority as a possible remedy to the Repugnant Conclusion. In this article, I demonstrate that, in a context where value is additive, this weaker form collapses into the stronger form of superiority...... of these results for different interpretations of Griffin's suggestion regarding population ethics. None of them comes out very successful, but perhaps they nevertheless retain some interest....

  19. Measuring Financial Gains from Genetically Superior Trees

    Science.gov (United States)

    George Dutrow; Clark Row

    1976-01-01

    Planting genetically superior loblolly pines will probably yield high profits.Forest economists have made computer simulations that predict financial gains expected from a tree improvement program under actual field conditions.

  20. Superior mesenteric artery syndrome causing growth retardation

    Directory of Open Access Journals (Sweden)

    Halil İbrahim Taşcı

    2013-03-01

    Full Text Available Superior mesenteric artery syndrome is a rare and lifethreateningclinical condition caused by the compressionof the third portion of the duodenum between the aortaand the superior mesenteric artery’s proximal part. Thiscompression may lead to chronic intermittent, acute totalor partial obstruction. Sudden weight-loss and the relateddecrease in the fat tissue are considered to be the etiologicalreason of acute stenosis. Weight-loss accompaniedby nausea, vomiting, anorexia, epigastric pain, andbloating are the leading complaints. Barium radiographs,computerized tomography, conventional angiography,tomographic and magnetic resonance angiography areused in the diagnosis. There are medical and surgical approachesto treatment. We hereby present the case ofa patient with superior mesenteric artery syndrome withdelayed diagnosis.Key words: superior mesenteric artery syndrome, nausea-vomiting, anorexia

  1. Leiomyosarcoma of the superior vena cava.

    Science.gov (United States)

    de Chaumont, Arthus; Pierret, Charles; de Kerangal, Xavier; Le Moulec, Sylvestre; Laborde, François

    2014-08-01

    Leiomyosarcoma of the superior vena cava is a very rare tumor and only a few cases have been reported, with various techniques of vascular reconstruction. We describe a new case of leiomyosarcoma of the superior vena cava in a 61-year-old woman with extension to the brachiocephalic arterial trunk. Resection and vascular reconstruction were performed using, respectively, polytetrafluoroethylene and polyethylene terephtalate vascular grafts.

  2. Superior mesenteric artery compression syndrome - case report

    OpenAIRE

    Paulo Rocha França Neto; Rodrigo de Almeida Paiva; Antônio Lacerda Filho; Fábio Lopes de Queiroz; Teon Noronha

    2011-01-01

    Superior mesenteric artery syndrome is an entity generally caused by the loss of the intervening mesenteric fat pad, resulting in compression of the third portion of the duodenum by the superior mesenteric artery. This article reports the case of a patient with irremovable metastatic adenocarcinoma in the sigmoid colon, that evolved with intense vomiting. Intestinal transit was carried out, which showed important gastric dilation extended until the third portion of the duodenum, compatible wi...

  3. Development of a thermal ionizer as ion catcher

    NARCIS (Netherlands)

    Traykov, E.; Dammalapati, U.; De, S.; Dermois, O. C.; Huisman, L.; Jungmann, K.; Kruithof, W.; Mol, A. J.; Onderwater, C. J. G.; Rogachevskiy, A.; da Silva e Silva, M.; Sohani, M.; Versolato, O.; Willmann, L.; Wilschut, H. W.

    2008-01-01

    An effective ion catcher is all important part of a radioactive beam Facility that is based on in-flight production. The catcher stops fast radioactive products and emits them as singly charged slow ions. Current ion catchers are based on stopping in He and H-2 gas. However, with increasing intensit

  4. Low-Pressure, Field-Ionizing Mass Spectrometer

    Science.gov (United States)

    Hartley, Frank; Smith, Steven

    2009-01-01

    A small mass spectrometer utilizing a miniature field ionization source is now undergoing development. It is designed for use in a variety of applications in which there are requirements for a lightweight, low-power-consumption instrument that can analyze the masses of a wide variety of molecules and ions. The device can operate without need for a high-vacuum, carrier-gas feed radioactive ionizing source, or thermal ionizer. This mass spectrometer can operate either in the natural vacuum of outer space or on Earth at any ambient pressure below 50 torr (below about 6.7 kPa) - a partial vacuum that can easily be reached by use of a small sampling pump. This mass spectrometer also has a large dynamic range - from singly charged small gas ions to deoxyribonucleic acid (DNA) fragments larger than 104 atomic mass units - with sensitivity adequate for detecting some molecules and ions at relative abundances of less than one part per billion. This instrument (see figure) includes a field ionizer integrated with a rotating-field mass spectrometer (RFMS). The field ionizer effects ionization of a type characterized as "soft" in the art because it does not fragment molecules or initiate avalanche arcing. What makes the "soft" ionization mode possible is that the distance between the ionizing electrodes is less than mean free path for ions at the maximum anticipated operating pressure, so that the ionizer always operates on the non-breakdown side of the applicable Paschen curve (a standard plot of breakdown potential on the ordinate and pressure electrode separation on the abscissa). The field ionizer in this instrument is fabricated by micromachining a submicron-thick membrane out of an electrically nonconductive substrate, coating the membrane on both sides to form electrodes, then micromachining small holes through the electrodes and membrane. Because of the submicron electrode separation, even a potential of only 1 V applied between the electrodes gives rise to an electric

  5. Comments on Ionization Cooling Channel Characteristics

    CERN Document Server

    Neuffer, David

    2013-01-01

    Ionization cooling channels with a wide variety of characteristics and cooling properties are being developed. These channels can produce cooling performances that are largely consistent with the ionization cooling theory developed previously. In this paper we review ionization cooling theory, discuss its application to presently developing cooling channels, and discuss criteria for optimizing cooling.

  6. 29 CFR 1926.53 - Ionizing radiation.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Ionizing radiation. 1926.53 Section 1926.53 Labor... § 1926.53 Ionizing radiation. (a) In construction and related activities involving the use of sources of ionizing radiation, the pertinent provisions of the Nuclear Regulatory Commission's Standards for...

  7. Comments on Ionization Cooling Channel Characteristics

    OpenAIRE

    Neuffer, David

    2013-01-01

    Ionization cooling channels with a wide variety of characteristics and cooling properties are being developed. These channels can produce cooling performances that are largely consistent with the ionization cooling theory developed previously. In this paper we review ionization cooling theory, discuss its application to presently developing cooling channels, and discuss criteria for optimizing cooling.

  8. Superior oblique surgery: when and how?

    Directory of Open Access Journals (Sweden)

    Taylan Şekeroğlu H

    2013-08-01

    Full Text Available Hande Taylan Şekeroğlu,1 Ali Sefik Sanac,1 Umut Arslan,2 Emin Cumhur Sener11Department of Ophthalmology, 2Department of Biostatistics, Hacettepe University Faculty of Medicine, Ankara, TurkeyBackground: The purpose of this paper is to review different types of superior oblique muscle surgeries, to describe the main areas in clinical practice where superior oblique surgery is required or preferred, and to discuss the preferred types of superior oblique surgery with respect to their clinical outcomes.Methods: A consecutive nonrandomized retrospective series of patients who had undergone superior oblique muscle surgery as a single procedure were enrolled in the study. The diagnosis, clinical features, preoperative and postoperative vertical deviations in primary position, type of surgery, complications, and clinical outcomes were reviewed. The primary outcome measures were the type of strabismus and the type of superior oblique muscle surgery. The secondary outcome measure was the results of the surgeries.Results: The review identified 40 (20 male, 20 female patients with a median age of 6 (2–45 years. Nineteen patients (47.5% had Brown syndrome, eleven (27.5% had fourth nerve palsy, and ten (25.0% had horizontal deviations with A pattern. The most commonly performed surgery was superior oblique tenotomy in 29 (72.5% patients followed by superior oblique tuck in eleven (27.5% patients. The amount of vertical deviation in the fourth nerve palsy and Brown syndrome groups (P = 0.01 for both and the amount of A pattern in the A pattern group were significantly reduced postoperatively (P = 0.02.Conclusion: Surgery for the superior oblique muscle requires experience and appropriate preoperative evaluation in view of its challenging nature. The main indications are Brown syndrome, fourth nerve palsy, and A pattern deviations. Superior oblique surgery may be effective in terms of pattern collapse and correction of vertical deviations in primary

  9. Modeling of Plutonium Ionization Probabilities for Use in Nuclear Forensic Analysis by Resonance Ionization Mass Spectrometry

    Science.gov (United States)

    2016-12-01

    material and chemical composition within the sample. This data can then be included in analysis by law enforcement and intelligence agencies to...PLUTONIUM IONIZATION PROBABILITIES FOR USE IN NUCLEAR FORENSIC ANALYSIS BY RESONANCE IONIZATION MASS SPECTROMETRY by Steven F. Hutchinson...IONIZATION PROBABILITIES FOR USE IN NUCLEAR FORENSIC ANALYSIS BY RESONANCE IONIZATION MASS SPECTROMETRY 5. FUNDING NUMBERS 6. AUTHOR(S) Steven F

  10. Biological decontamination of surfaces using guided ionization waves

    Science.gov (United States)

    Jarrige, Julien; Zaepffel, Clement

    2016-09-01

    Atmospheric pressure plasma jets have received an increasing attention these last ten years in various domains, including biomedical applications and decontamination. Among these technologies, guided ionization waves (also called ``plasma bullets'') are very promising because of their ability to produce a highly non-equilibrium plasma. Reactive species can be generated in the open air over a long distance during the propagation of the wave (typically: several cm), while the background gas remains at ambient temperature. A non-thermal plasma system has been developed and tested for the biological decontamination of surfaces. It consists of a dielectric barrier discharge in a helium flow driven by high voltage pulses. The propagation of the ionization wave and the spatial distribution of the species have been characterized by high speed imaging and optical emission spectroscopy. The influence of the discharge parameters on the plasma properties is investigated. Results of decontamination on several bacteria are shown, and the decontamination efficiency is compared with the plasma properties.

  11. Electron-Impact Ionization and Dissociative Ionization of Biomolecules

    Science.gov (United States)

    Huo, Winifred M.; Chaban, Galina M.; Dateo, Christopher E.

    2006-01-01

    It is well recognized that secondary electrons play an important role in radiation damage to humans. Particularly important is the damage of DNA by electrons, potentially leading to mutagenesis. Molecular-level study of electron interaction with DNA provides information on the damage pathways and dominant mechanisms. Our study of electron-impact ionization of DNA fragments uses the improved binary-encounter dipole model and covers DNA bases, sugar phosphate backbone, and nucleotides. An additivity principle is observed. For example, the sum of the ionization cross sections of the separate deoxyribose and phosphate fragments is in close agreement with the C3(sup prime)- and C5 (sup prime)-deoxyribose-phospate cross sections, differing by less than 5%. Investigation of tandem double lesion initiated by electron-impact dissociative ionization of guanine, followed by proton reaction with the cytosine in the Watson-Crick pair, is currently being studied to see if tandem double lesion can be initiated by electron impact. Up to now only OH-induced tandem double lesion has been studied.

  12. Adsorption of Emerging Ionizable Contaminants on Carbon Nanotubes: Advancements and Challenges

    Directory of Open Access Journals (Sweden)

    Xingmao Ma

    2016-05-01

    Full Text Available The superior adsorption capacity of carbon nanotubes has been well recognized and there is a wealth of information in the literature concerning the adsorption of unionized organic pollutants on carbon nanotubes. Recently, the adsorption of emerging environmental pollutants, most of which are ionizable, has attracted increasing attention due to the heightened concerns about the accumulation of these emerging contaminants in the environment. These recent studies suggest that the adsorption of emerging ionizable contaminants on carbon nanotubes exhibit different characteristics than unionized ones. For example, a new charge-assisted intermolecular force has been proposed for ionizable compounds because some adsorption phenomenon cannot be easily explained by the conventional force theory. The adsorption of ionizable compounds also displayed much stronger dependence on solution pH and ionic strength than unionized compounds. This article aims to present a brief review on the current understanding of the adsorption of emerging ionizable contaminants to carbon nanotubes and discuss further research needs required to advance the mechanistic understanding of the interactions between ionizable contaminants and carbon nanotubes.

  13. Turbulence in the ionized gas of the Orion nebula

    Science.gov (United States)

    Arthur, S. J.; Medina, S.-N. X.; Henney, W. J.

    2016-12-01

    In order to study the nature, origin, and impact of turbulent velocity fluctuations in the ionized gas of the Orion nebula, we apply a variety of statistical techniques to observed velocity cubes. The cubes are derived from high resolving power (R ≈ 40 000) longslit spectroscopy of optical emission lines that span a range of ionizations. From velocity channel analysis (VCA), we find that the slope of the velocity power spectrum is consistent with predictions of Kolmogorov theory between scales of 8 and 22 arcsec (0.02 to 0.05 pc). The outer scale, which is the dominant scale of density fluctuations in the nebula, approximately coincides with the autocorrelation length of the velocity fluctuations that we determine from the second-order velocity structure function. We propose that this is the principal driving scale of the turbulence, which originates in the autocorrelation length of dense cores in the Orion molecular filament. By combining analysis of the non-thermal linewidths with the systematic trends of velocity centroid versus ionization, we find that the global champagne flow and smaller scale turbulence each contribute in equal measure to the total velocity dispersion, with respective root-mean-square widths of 4-5 km s-1. The turbulence is subsonic and can account for only one half of the derived variance in ionized density, with the remaining variance provided by density gradients in photoevaporation flows from globules and filaments. Intercomparison with results from simulations implies that the ionized gas is confined to a thick shell and does not fill the interior of the nebula.

  14. Monte Carlo approach to calculate ionization dynamics of hot solid-density plasmas within particle-in-cell simulations

    Science.gov (United States)

    Wu, D.; He, X. T.; Yu, W.; Fritzsche, S.

    2017-02-01

    A physical model based on a Monte Carlo approach is proposed to calculate the ionization dynamics of hot-solid-density plasmas within particle-in-cell (PIC) simulations, and where the impact (collision) ionization (CI), electron-ion recombination (RE), and ionization potential depression (IPD) by surrounding plasmas are taken into consideration self-consistently. When compared with other models, which are applied in the literature for plasmas near thermal equilibrium, the temporal relaxation of ionization dynamics can also be simulated by the proposed model. Besides, this model is general and can be applied for both single elements and alloys with quite different compositions. The proposed model is implemented into a PIC code, with (final) ionization equilibriums sustained by competitions between CI and its inverse process (i.e., RE). Comparisons between the full model and model without IPD or RE are performed. Our results indicate that for bulk aluminium at temperature of 1 to 1000 eV, (i) the averaged ionization degree increases by including IPD; while (ii) the averaged ionization degree is significantly over estimated when the RE is neglected. A direct comparison from the PIC code is made with the existing models for the dependence of averaged ionization degree on thermal equilibrium temperatures and shows good agreements with that generated from Saha-Boltzmann model and/or FLYCHK code.

  15. Thermal imaging in medicine

    Directory of Open Access Journals (Sweden)

    Jaka Ogorevc

    2015-12-01

    Full Text Available AbstractIntroduction: Body temperature monitoring is one of the oldest and still one of the most basic diagnostic methods in medicine. In recent years thermal imaging has been increasingly used in measurements of body temperature for diagnostic purposes. Thermal imaging is non-invasive, non-contact method for measuring surface body temperature. Method is quick, painless and patient is not exposed to ionizing radiation or any other body burden.Application of thermal imaging in medicine: Pathological conditions can be indicated as hyper- or hypothermic patterns in many cases. Thermal imaging is presented as a diagnostic method, which can detect such thermal anomalies. This article provides an overview of the thermal imaging applications in various fields of medicine. Thermal imaging has proven to be a suitable method for human febrile temperature screening, for the detection of sites of fractures and infections, a reliable diagnostic tool in the detection of breast cancer and determining the type of skin cancer tumour. It is useful in monitoring the course of a therapy after spinal cord injury, in the detection of food allergies and detecting complications at hemodialysis and is also very effective at the course of treatment of breast reconstruction after mastectomy. With thermal imaging is possible to determine the degrees of burns and early detection of osteomyelitis in diabetic foot phenomenon. The most common and the oldest application of thermal imaging in medicine is the field of rheumatology.Recommendations for use and standards: Essential performance of a thermal imaging camera, measurement method, preparation of a patient and environmental conditions are very important for proper interpretation of measurement results in medical applications of thermal imaging. Standard for screening thermographs was formed for the human febrile temperature screening application.Conclusion: Based on presented examples it is shown that thermal imaging can

  16. Ionization potentials some variations, implications and applications

    CERN Document Server

    Ahrens, L H

    1983-01-01

    Ionization Potentials: Some Variations, Implications and Applications covers several aspects of ionization potential that is a highly significant parameter in controlling the properties of electric discharge. Comprised of 17 chapters, the book covers topic relevant to ionization potentials, such as properties, concepts, and applications, in order to understand and fully comprehend all aspects of ionization potential. The opening chapter is a review of ionization potentials and a discussion of trends and features. The succeeding chapters then tackle complex topics such as the s and p electrons;

  17. Biological effects of ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Blaylock, B.G. [SENES Oak Ridge Inc., Oak Ridge, TN (United States); Theodorakis, C.W.; Shugart, L.R. [Oak Ridge National Lab., Oak Ridge, TN (United States). Environmental Sciences Division

    1996-12-31

    Natural populations have always been exposed to background levels of ionizing radiation; however, with the event of the nuclear age, studies about the effects of higher-than-background levels of ionizing radiation on individuals or populations of organisms became important. Originally, concern was focused on survival after large, acute radiation doses, and numerous studies document the somatic and genetic effects of acute ionizing radiation. However, there is a growing realization that chronic long-term exposure to higher-than-background levels of environmental radiation is more likely than is large acute exposure. Less than 10% of the literature on ionizing radiation effects deals with chronic long-term effects, and very few studies involve natural populations. In 1977, mosquito fish, Gambusia affinis, were experimentally introduced into a 0,45 ha, decommissioned, radioactive waste pond where the measured dose at the sediment-water interface was 1,150 rad/year. One year later, the fecundity of the population had not changed significantly. Eighteen years later, studies of the fish showed an inverse correlation between DNA strand breakage and fecundity in the contaminated pond. More recent studies have provided evidence that genetic diversity of the fish has increased in the contaminated site. These fish also have a greater prevalence of certain DNA banding patterns. Individuals displaying these banding patterns have a higher fecundity and lower degree of DNA strand breakage than individuals with less common banding patterns. Gambusia affinis has apparently adapted to the high background radiation, successfully surviving for approximately 50 generations. 31 refs, 5 figs.

  18. The dosimetry of ionizing radiation

    CERN Document Server

    1990-01-01

    A continuation of the treatise The Dosimetry of Ionizing Radiation, Volume III builds upon the foundations of Volumes I and II and the tradition of the preceeding treatise Radiation Dosimetry. Volume III contains three comprehensive chapters on the applications of radiation dosimetry in particular research and medical settings, a chapter on unique and useful detectors, and two chapters on Monte Carlo techniques and their applications.

  19. Whisker-related afferents in superior colliculus.

    Science.gov (United States)

    Castro-Alamancos, Manuel A; Favero, Morgana

    2016-05-01

    Rodents use their whiskers to explore the environment, and the superior colliculus is part of the neural circuits that process this sensorimotor information. Cells in the intermediate layers of the superior colliculus integrate trigeminotectal afferents from trigeminal complex and corticotectal afferents from barrel cortex. Using histological methods in mice, we found that trigeminotectal and corticotectal synapses overlap somewhat as they innervate the lower and upper portions of the intermediate granular layer, respectively. Using electrophysiological recordings and optogenetics in anesthetized mice in vivo, we showed that, similar to rats, whisker deflections produce two successive responses that are driven by trigeminotectal and corticotectal afferents. We then employed in vivo and slice experiments to characterize the response properties of these afferents. In vivo, corticotectal responses triggered by electrical stimulation of the barrel cortex evoke activity in the superior colliculus that increases with stimulus intensity and depresses with increasing frequency. In slices from adult mice, optogenetic activation of channelrhodopsin-expressing trigeminotectal and corticotectal fibers revealed that cells in the intermediate layers receive more efficacious trigeminotectal, than corticotectal, synaptic inputs. Moreover, the efficacy of trigeminotectal inputs depresses more strongly with increasing frequency than that of corticotectal inputs. The intermediate layers of superior colliculus appear to be tuned to process strong but infrequent trigeminal inputs and weak but more persistent cortical inputs, which explains features of sensory responsiveness, such as the robust rapid sensory adaptation of whisker responses in the superior colliculus. Copyright © 2016 the American Physiological Society.

  20. Low-level measurements of Ra-226/Rn-222 by pulse ionization chambers

    Science.gov (United States)

    El-Daoushy, Fand; Garcia-Tenorio, Rafael

    1988-10-01

    Characteristics of two ionization chambers have been studied and the chambers utilized for 226Ra/ 222Rn measurements for more than ten years. The results obtained show that coating of internal surfaces with a pure and thin Ag-layer enhances the background of ionization chambers in spite of some improvements at the early stages of operation. In addition to previously known parameters influencing the accuracy in routine measurements, new correction factors are suggested. 226Ra impurities in the body of ionization chambers are found to act not only as a permanent, but also as a temperature-dependent source of background. Earlier accuracies of 226Ra/ 222Rn measurements have been considerably improved by assuring long-term mechanical and thermal stability of the ionization chambers.

  1. Turbulence and the ionization of interstellar gas

    Science.gov (United States)

    Hill, Alex S.

    2015-08-01

    Turbulence is widely observed in the ionized gas in the interstellar media of star-forming galaxies. Observations in the Milky Way indicate emission from that the warm ionized medium -- ionized gas far from massive stars, the most likely source of the ionization -- has a lognormal intensity distribution. This and other measurements indicate that the gas is well-described as a transonic turbulent fluid. Such a fluid can be produced by feedback from supernovae in the Galaxy. Understanding of this turbulence has also led to a natural explanation for a long-standing puzzle: how do ionizing photons travel through the largely-neutral interstellar medium and produce the ionization? In the turbulent gas, low-density pathways allow ionizing photons to propagate for kiloparsecs, with implications for radiative energy transport in star-forming galaxies.

  2. Loss of ions in cavity ionization chambers

    Energy Technology Data Exchange (ETDEWEB)

    Takata, N. [Ionizing Radiation Section, NMIJ/AIST, Tsukuba 305-8568 (Japan)]. E-mail: n.takata@aist.go.jp; Tran, N.T. [Institute for Nuclear Science and Technique, VAEC, Hanoi (Viet Nam); Kim, E. [Radiation Safety Section, NIRS, Inageku, Chiba-city 263-8555 (Japan); Marsoem, P. [P3KRBiN-BATAN, JL Cinere-Pasar Jum' at, Jakarta 12070 (Indonesia); Kurosawa, T. [Ionizing Radiation Section, NMIJ/AIST, Tsukuba 305-8568 (Japan); Koyama, Y. [Ionizing Radiation Section, NMIJ/AIST, Tsukuba 305-8568 (Japan)

    2005-12-01

    Ion losses due to initial recombination, volume recombination, and back diffusion were each determined by measurements and calculations for different size cylindrical ionization chambers and spherical ionization chambers. By measuring signal currents from these ionization chambers irradiated with {sup 60}Co gamma rays, two groups of ion losses were obtained. (Group 1) Ion loss due to initial recombination and diffusion, which changes proportionally to the inverse of the voltage applied to the ionization chambers; (and group 2) ion loss due to volume recombination, which changes proportionally to the inverse of the square of the applied voltage. The diffusion loss was obtained separately by computing electric field distributions in the ionization chambers. It was found that diffusion loss is larger than initial recombination loss for the cylindrical ionization chambers and vise versa for the spherical ionization chambers.

  3. 热降解辅助表面解吸常压化学电离质谱对阿莫西林的分析%Analysis of amoxicillin by surface desorption atmospheric pressure chemical ionization mass spectrometry aided with thermal degradation

    Institute of Scientific and Technical Information of China (English)

    陈荣; 邓慧宇; 石俊

    2012-01-01

    To establish a novel approach to the high throughput screening of amoxicillin by direct surface desorption atmospheric pressure chemical ionization -mass spectrometry aided with thermal degradation(TD -SDAP-CI - MS). Methods; Water in the air act as the reactive reagent responsible for the generation of ions in the positive corona discharge. The rapid screening effectiveness of the combination of TD and SDAPGI was demonstrated by application to comparing the total ion current mass spectrum of degradation ingredient ions to ion current mass spectrum of amoxicillin capsules which were observed in full scan mass spectrometry (MS) mode. Collision -induced dissociation of protonated molecules gave characteristic product - ion mass spectra and provided further identification of amoxicillin degradation ingredients. Results: The high throughput screening of amoxicillin was realized by mass spectrum without sample pretreatment and separation step. Conclusions: A single sample analysis is completed in less than 30 seconds. The data show TD - SDAPCI - MS is a convenient tool for high throughtout screening of unstable amoxicillin.%目的:建立一种阿莫西林热降解辅助表面解吸常压化学电离质谱(TD - SDAPCI - MS)快速检测新方法.方法:利用阿莫西林抗生素的易降解并产生特定降解产物的特性,以潮湿空气作为试剂,通过电晕放电产生大量试剂离子,对阿莫西林抗生素总离子流质谱图与特征降解产物离子流图进行比对.并通过串联质谱对阿莫西林抗生素产生的特征降解产物进行了确认.结果:无需样品预处理,实现一级质谱法对阿莫西林抗生素的高通量筛选.结论:单个样品检测不超过30 s,可实现不稳定抗生素阿莫西林的高通量筛选.

  4. Ghost peaks observed after atmospheric pressure matrix-assisted laser desorption/ionization experiments may disclose new ionization mechanism of matrix-assisted hypersonic velocity impact ionization.

    Science.gov (United States)

    Moskovets, Eugene

    2015-08-30

    Understanding the mechanisms of matrix-assisted laser desorption/ionization (MALDI) promises improvements in the sensitivity and specificity of many established applications in the field of mass spectrometry. This paper reports a serendipitous observation of a significant ion yield in a post-ionization experiment conducted after the sample had been removed from a standard atmospheric pressure (AP)-MALDI source. This post-ionization is interpreted in terms of collisions of microparticles moving with a hypersonic velocity into a solid surface. Calculations show that the thermal energy released during such collisions is close to that absorbed by the top matrix layer in traditional MALDI. The microparticles, containing both the matrix and analytes, could be detached from a film produced inside the inlet capillary during the sample ablation and accelerated by the flow rushing through the capillary. These observations contribute some new perspective to ion formation in both laser and laser-less matrix-assisted ionization. An AP-MALDI ion source hyphenated with a three-stage high-pressure ion funnel system was utilized for peptide mass analysis. After the laser had been turned off and the MALDI sample removed, ions were detected during a gradual reduction of the background pressure in the first funnel. The constant-rate pressure reduction led to the reproducible appearance of different singly and doubly charged peptide peaks in mass spectra taken a few seconds after the end of the MALDI analysis of a dried-droplet spot. The ion yield as well as the mass range of ions observed with a significant delay after a completion of the primary MALDI analysis depended primarily on the background pressure inside the first funnel. The production of ions in this post-ionization step was exclusively observed during the pressure drop. A lower matrix background and significant increase in relative yield of double-protonated ions are reported. The observations were partially consistent

  5. Superior-subordinate relations as organizational processes

    DEFF Research Database (Denmark)

    Asmuss, Birte; Aggerholm, Helle Kryger; Oshima, Sae

    Since the emergence of the practice turn in social sciences (Golsorkhi et al. 2010), studies have shown a number of institutionally relevant aspects as achievements across time and by means of various resources (human and non-human) (Taylor & van Every 2000, Cooren et al. 2006). Such a process view...... on organizational practices relates closely to an increased focus on communication as being constitutive of the organization in general and the superior-subordinate relationship in specific. The current study aims to contribute to this line of research by investigating micro-practices involved in establishing...... superior-subordinate relations in a specific institutionalized setting: performance appraisal interviews (PAIs). While one main task of PAIs is to manage and integrate organizational and employee performance (Fletcher, 2001:473), PAIs are also organizational practices where superior-subordinate relations...

  6. Lake Superior Aquatic Invasive Species Complete Prevention Plan

    Science.gov (United States)

    The Lake Superior Aquatic Invasive Species Complete Prevention Plan is an expression of the best professional judgment of the members of the Lake Superior Task Force as to what is necessary to protect Lake Superior from new aquatic invasive species.

  7. Endovascular treatment of superior vena cava syndrome

    DEFF Research Database (Denmark)

    Duvnjak, Stevo; Andersen, Poul Erik

    2011-01-01

    Abstract AIM: The aim of this study was to report our experience with palliative stent treatment of superior vena cava syndrome. METHODS: Between January 2008 and December 2009, 30 patients (mean age 60.7 years) were treated with stents because of stenosed superior vena cava. All patients presented...... there was an immediate clinical improvement with considerable reduction in the edema of upper extremities and head. There was, however, continous dyspnea in five patients (17%) and two patients (7%) had persistent visible collateral venous circulations on the upper chest. There were no stent associated complications...

  8. Cross sections and coherence terms for associative ionization of two differently excited Na(3p) atoms

    NARCIS (Netherlands)

    Meijer, H.A.J.; Pelgrim, T.J.C.; Heideman, H.G.M.; Morgenstern, R.; Andersen, N.

    1989-01-01

    The associative ionization process in thermal Na(3p)-Na(3p) encounters has been studied in a series of crossed-beam experiments where the light polarization of the two laser beams preparing the excited atoms before collision was varied independently. It is shown how in this way maximum possible info

  9. Polarization forces in the vicinity of nanoparticles in weakly ionized plasma

    CERN Document Server

    Shneider, M N

    2016-01-01

    It is shown that the polarization forces in a weakly ionized plasma lead to a substantial increase in the fluxes of neutral atoms and molecules to the surface of charged nanoparticles. Thus, the nanoparticles can change thermal balance due to the acceleration of atoms and molecules in the dipole potential and subsequent inelastic collisions to the nanoparticles.

  10. Magnetic resonance imaging evaluation of meniscoid superior labrum: normal variant or superior labral tear*

    Science.gov (United States)

    Simão, Marcelo Novelino; Vinson, Emily N.; Spritzer, Charles E.

    2016-01-01

    Objective The objective of this study was to determine the incidence of a "meniscoid" superior labrum. Materials and Methods This was a retrospective analysis of 582 magnetic resonance imaging examinations of shoulders. Of those 582 examinations, 110 were excluded, for a variety of reasons, and the final analysis therefore included 472 cases. Consensus readings were performed by three musculoskeletal radiologists using specific criteria to diagnose meniscoid labra. Results A meniscoid superior labrum was identified in 48 (10.2%) of the 472 cases evaluated. Arthroscopic proof was available in 21 cases (43.8%). In 10 (47.6%) of those 21 cases, the operative report did not include the mention a superior labral tear, thus suggesting the presence of a meniscoid labrum. In only one of those cases were there specific comments about a mobile superior labrum (i.e., meniscoid labrum). In the remaining 11 (52.4%), surgical correlation demonstrated superior labral tears. Conclusion A meniscoid superior labrum is not an infrequent finding. Depending upon assumptions and the requirement of surgical proof, the prevalence of a meniscoid superior labrum in this study was between 2.1% (surgically proven) and 4.8% (projected). However, superior labral tears are just as common and are often confused with meniscoid labra. PMID:27777474

  11. Space Flight Ionizing Radiation Environments

    Science.gov (United States)

    Koontz, Steve

    2017-01-01

    The space-flight ionizing radiation (IR) environment is dominated by very high-kinetic energy-charged particles with relatively smaller contributions from X-rays and gamma rays. The Earth's surface IR environment is not dominated by the natural radioisotope decay processes. Dr. Steven Koontz's lecture will provide a solid foundation in the basic engineering physics of space radiation environments, beginning with the space radiation environment on the International Space Station and moving outward through the Van Allen belts to cislunar space. The benefits and limitations of radiation shielding materials will also be summarized.

  12. Tunneling Ionization of Diatomic Molecules

    DEFF Research Database (Denmark)

    Svensmark, Jens Søren Sieg

    2016-01-01

    When a molecule is subject to a strong laser field, there is a probability that an electron can escape, even though the electrons are bound by a large potential barrier. This is possible because electrons are quantum mechanical in nature, and they are therefore able to tunnel through potential...... of tunneling ionizaion of molecules is presented and the results of numerical calculations are shown. One perhaps surprising result is, that the frequently used Born-Oppenheimer approximation breaks down for weak fields when describing tunneling ionization. An analytic theory applicable in the weak-field limit...

  13. XUV ionization of aligned molecules

    Energy Technology Data Exchange (ETDEWEB)

    Kelkensberg, F.; Siu, W.; Gademann, G. [FOM Institute AMOLF, Science Park 104, NL-1098 XG Amsterdam (Netherlands); Rouzee, A.; Vrakking, M. J. J. [FOM Institute AMOLF, Science Park 104, NL-1098 XG Amsterdam (Netherlands); Max-Born-Institut, Max-Born Strasse 2A, D-12489 Berlin (Germany); Johnsson, P. [FOM Institute AMOLF, Science Park 104, NL-1098 XG Amsterdam (Netherlands); Department of Physics, Lund University, Post Office Box 118, SE-221 00 Lund (Sweden); Lucchini, M. [Department of Physics, Politecnico di Milano, Istituto di Fotonica e Nanotecnologie CNR-IFN, Piazza Leonardo da Vinci 32, 20133 Milano (Italy); Lucchese, R. R. [Department of Chemistry, Texas A and M University, College Station, Texas 77843-3255 (United States)

    2011-11-15

    New extreme-ultraviolet (XUV) light sources such as high-order-harmonic generation (HHG) and free-electron lasers (FELs), combined with laser-induced alignment techniques, enable novel methods for making molecular movies based on measuring molecular frame photoelectron angular distributions. Experiments are presented where CO{sub 2} molecules were impulsively aligned using a near-infrared laser and ionized using femtosecond XUV pulses obtained by HHG. Measured electron angular distributions reveal contributions from four orbitals and the onset of the influence of the molecular structure.

  14. Fiber optic ionizing radiation detector

    Energy Technology Data Exchange (ETDEWEB)

    Suter, J.J. (Johns Hopkins Univ., Applied Physics Lab., Laurel, MD (United States)); Poret, J.C.; Rosen, M. (Johns Hopkins Univ., Dept. of Materials Science and Engineering, Baltimore, MD (United States))

    1992-08-01

    Radiation detection can be done by various types of devices, such as Geiger counters, thermoluminescent detectors, and electric field sensors. This paper reports on a noel design for an ionizing radiation sensor using coiled optical fibers, which can be placed within or near a radioactive source. This design has several features that make it different from sensors proposed in the past. In order to evaluate this sensor, coiled fiber samples were placed inside metallic and metal-matrix composite cylinders to evaluate the sensitivity of the detector as well as the shielding effectiveness of the materials.

  15. Polymerization, shock cooling and ionization of liquid nitrogen

    Energy Technology Data Exchange (ETDEWEB)

    Ross, M; Rogers, F

    2005-07-21

    The trajectory of thermodynamic states passed through by the nitrogen Hugoniot starting from the liquid and up to 10{sup 6} GPa has been studied. An earlier report of cooling in the doubly shocked liquid, near 50 to 100 GPa and 7500 K, is revisited in light of the recent discovery of solid polymeric nitrogen. It is found that cooling occurs when the doubly shocked liquid is driven into a volume near the molecular to polymer transition and raising the possibility of a liquid-liquid phase transition (LLPT). By increasing the shock pressure and temperature by an order of magnitude, theoretical calculations predict thermal ionization of the L shell drives the compression maxima to 5-6 fold compression at 10 Mbar (T {approx} 3.5 10{sup 5} K) and at 400 Mbar (T {approx} 2.3 10{sup 6} K) from K shell ionization. Near a pressure of 10{sup 6} GPa the K shell ionizes completely and the Hugoniot approaches the classical ideal gas compression fourfold limit.

  16. Towards a Carbon Nanotube Ionization Source for Planetary Atmosphere Exploration

    Science.gov (United States)

    Oza, A. V.; Leblanc, F.; Berthelier, J. J.; Becker, J.; Coulomb, R.; Gilbert, P.; Hong, N. T.; Lee, S.; Vettier, L.

    2015-12-01

    The characterization of planetary exospheres today, relies on the development of a highly efficient ionization source, due to the scant neutral molecules (n atmospheres provide insight on to physical processes known to occur such as: space weathering, magneto-atmosphere interactions, as well as atmospheric escape mechanisms, all of which are being heavily investigated via current 3D Monte Carlo simulations (Turc et al. 2014, Leblanc et al. 2016 in prep) at LATMOS. Validation of these studies will rely on in-situ observations in the coming decades. Neutral detection strongly depends on electron-impact ionization which via conventional cathode-sources, such as thermal filaments (heated up to 2000 K), may only produce the target ionization essential for energy-measurements with large power consumption. Carbon nanotubes (CNTs) however are ideal low-power, cold cathodes, when subject to moderate electric fields (E ~ 1 MV / m). We present our current device, a small CNT chip, of emission area 15 mm2, emitting electrons that pass through an anode grid and subsequent electrostatic analyzer. The device currently extracts hundreds of µAmperes with applied external voltages ~ -150 Volts, approaching minimum power consumption plasma sputtering the icy regolith with heavy ions and electrons (keV < E < MeV), producing predominately molecular oxygen (Johnson et al. 2002).

  17. Spatially discontinuous ionization phenomenon in inhomogeneous soil

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    By using X-ray film imaging technology,a phenomenon of discontinuous ionization was observed in the inhomogeneous soil around the grounding electrode on which a surge voltage was applied.A simplified two-phase solid-gas model was built to study the electric field distribution in the soil to explain the discontinuous ionization phenomenon.Analysis showed the differences of the dielectric properties,the shapes and sizes of soil particles can cause discontinuous ionization in the soil.

  18. K-shell ionization by antiprotons

    Energy Technology Data Exchange (ETDEWEB)

    Mehler, G.; Mueller, B.; Greiner, W.; Soff, G.

    1987-08-01

    We present calculations for the impact-parameter dependence of K-shell ionization rates in p-bar-Cu and in p-bar-Ag collisions at various projectile energies. We show that the effect of the attractive Coulomb potential on the Rutherford trajectory and the antibinding effect caused by the negative charge of the antiproton result in a considerable increase of the ionization probability. Total ionization cross sections for proton and antiproton projectiles are compared with each other and with experimental ionization cross sections for protons.

  19. Ionization probes of molecular structure and chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, P.M. [State Univ. of New York, Stony Brook (United States)

    1993-12-01

    Various photoionization processes provide very sensitive probes for the detection and understanding of the spectra of molecules relevant to combustion processes. The detection of ionization can be selective by using resonant multiphoton ionization or by exploiting the fact that different molecules have different sets of ionization potentials. Therefore, the structure and dynamics of individual molecules can be studied even in a mixed sample. The authors are continuing to develop methods for the selective spectroscopic detection of molecules by ionization, and to use these methods for the study of some molecules of combustion interest.

  20. Influence of renormalization shielding on the electron-impact ionization process in dense partially ionized plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Song, Mi-Young; Yoon, Jung-Sik [Plasma Technology Research Center, National Fusion Research Institute, 814-2 Osikdo-Dong, Gunsan-City, Jeollabuk-Do 573-540 (Korea, Republic of); Jung, Young-Dae, E-mail: ydjung@hanyang.ac.kr [Department of Physics, Applied Physics, and Astronomy, Rensselaer Polytechnic Institute, 110 8th Street, Troy, New York 12180-3590 (United States); Department of Applied Physics and Department of Bionanotechnology, Hanyang University, Ansan, Kyunggi-Do 426-791 (Korea, Republic of)

    2015-04-15

    The renormalization shielding effects on the electron-impact ionization of hydrogen atom are investigated in dense partially ionized plasmas. The effective projectile-target interaction Hamiltonian and the semiclassical trajectory method are employed to obtain the transition amplitude as well as the ionization probability as functions of the impact parameter, the collision energy, and the renormalization parameter. It is found that the renormalization shielding effect suppresses the transition amplitude for the electron-impact ionization process in dense partially ionized plasmas. It is also found that the renormalization effect suppresses the differential ionization cross section in the peak impact parameter region. In addition, it is found that the influence of renormalization shielding on the ionization cross section decreases with an increase of the relative collision energy. The variations of the renormalization shielding effects on the electron-impact ionization cross section are also discussed.

  1. Ionization cross section for a strongly coupled partially ionized hydrogen plasma: variable phase approach

    Energy Technology Data Exchange (ETDEWEB)

    Baimbetov, F B; Kudyshev, Z A [Department of Physics, Al-Farabi Kazakh National University, 050012 Almaty (Kazakhstan)], E-mail: Fazylhan.Baimbetov@kaznu.kz, E-mail: Z.Kudyshev@mail.ru

    2009-05-29

    In the present work an electron impact ionization cross section is considered. The electron impact ionization cross section is calculated with the help of a variable phase approach to potential scattering. The Calogero equation is numerically solved, based on a pseudopotential model of interaction between partially ionized plasma particles, which accounts for correlation effects. As a result, scattering phase shifts are obtained. On the basis of the scattering phase shifts, the ionization cross section is calculated.

  2. Superior-subordinate relations as organizational processes

    DEFF Research Database (Denmark)

    Asmuss, Birte; Aggerholm, Helle Kryger; Oshima, Sae

    Since the emergence of the practice turn in social sciences (Golsorkhi et al. 2010), studies have shown a number of institutionally relevant aspects as achievements across time and by means of various resources (human and non-human) (Taylor & van Every 2000, Cooren et al. 2006). Such a process view...... superior-subordinate relations in a specific institutionalized setting: performance appraisal interviews (PAIs). While one main task of PAIs is to manage and integrate organizational and employee performance (Fletcher, 2001:473), PAIs are also organizational practices where superior-subordinate relations...... are shaped, (re)confirmed and re-evaluated. This paper pursues the better understanding of the latter aspect by looking at one substantial and recurrent activity in PAIs: the evaluation of employee performance. One resource for doing the evaluation work is making assessments (e.g. Goodwin & Goodwin, 1987...

  3. Exploring the word superiority effect using TVA

    DEFF Research Database (Denmark)

    Starrfelt, Randi

    Words are made of letters, and yet sometimes it is easier to identify a word than a single letter. This word superiority effect (WSE) has been observed when written stimuli are presented very briefly or degraded by visual noise. It is unclear, however, if this is due to a lower threshold...... for perception of words, or a higher speed of processing for words than letters. We have investigated the WSE using methods based on a Theory of Visual Attention. In an experiment using single stimuli (words or letters) presented centrally, we show that the classical WSE is specifically reflected in perceptual...... processing speed: words are simply processed faster than single letters. It is also clear from this experiment, that the word superiority effect can be observed at a large range of exposure durations, from the perceptual threshold to ceiling performance. Intriguingly, when multiple stimuli are presented...

  4. Transport properties of partially ionized and unmagnetized plasmas

    Science.gov (United States)

    Magin, Thierry E.; Degrez, Gérard

    2004-10-01

    This work is a comprehensive and theoretical study of transport phenomena in partially ionized and unmagnetized plasmas by means of kinetic theory. The pros and cons of different models encountered in the literature are presented. A dimensional analysis of the Boltzmann equation deals with the disparity of mass between electrons and heavy particles and yields the epochal relaxation concept. First, electrons and heavy particles exhibit distinct kinetic time scales and may have different translational temperatures. The hydrodynamic velocity is assumed to be identical for both types of species. Second, at the hydrodynamic time scale the energy exchanged between electrons and heavy particles tends to equalize both temperatures. Global and species macroscopic fluid conservation equations are given. New constrained integral equations are derived from a modified Chapman-Enskog perturbative method. Adequate bracket integrals are introduced to treat thermal nonequilibrium. A symmetric mathematical formalism is preferred for physical and numerical standpoints. A Laguerre-Sonine polynomial expansion allows for systems of transport to be derived. Momentum, mass, and energy fluxes are associated to shear viscosity, diffusion coefficients, thermal diffusion coefficients, and thermal conductivities. A Goldstein expansion of the perturbation function provides explicit expressions of the thermal diffusion ratios and measurable thermal conductivities. Thermal diffusion terms already found in the Russian literature ensure the exact mass conservation. A generalized Stefan-Maxwell equation is derived following the method of Kolesnikov and Tirskiy. The bracket integral reduction in terms of transport collision integrals is presented in Appendix for the thermal nonequilibrium case. A simple Eucken correction is proposed to deal with the internal degrees of freedom of atoms and polyatomic molecules, neglecting inelastic collisions. The authors believe that the final expressions are

  5. A search for ionized jets towards massive young stellar objects

    CERN Document Server

    Purser, S J D; Hoare, M G; Urquhart, J S; Cunningham, N; Purcell, C R; Brooks, K J; Garay, G; Gúzman, A E; Voronkov, M A

    2016-01-01

    Radio continuum observations using the Australia telescope compact array at 5.5, 9.0, 17.0 and 22.8 GHz have detected free-free emission associated with 45 of 49 massive young stellar objects and HII regions. Of these, 26 sources are classified as ionized jets (12 of which are candidates), 2 as ambiguous jets or disc winds, 1 as a disc-wind, 14 as HII regions and 2 were unable to be categorised. Classification as ionized jets is based upon morphology, radio flux and spectral index, in conjunction with previous observational results at other wavelengths. Radio-luminosity and momentum are found to scale with bolometric luminosity in the same way as low-mass jets, indicating a common mechanism for jet production across all masses. In 13 of the jets, we see associated non-thermal/optically-thin lobes resulting from shocks either internal to the jet and/or at working surfaces. Ten jets display non-thermal (synchrotron emission) spectra in their lobes, with an average spectral index of -0.55 consistent with Fermi a...

  6. Resolution of superior oblique myokymia with memantine.

    Science.gov (United States)

    Jain, Saurabh; Farooq, Shegufta J; Gottlob, Irene

    2008-02-01

    We describe a novel treatment of superior oblique myokymia. A 40-year-old woman was treated with gabapentin for this disorder with partial success and reported significant side effects including loss of libido and weight gain. After a drug holiday, memantine therapy was initiated resulting in a substantial improvement in her symptoms with far fewer side effects and stability on long-term maintenance therapy.

  7. Locked Superior Dislocation of the Acromioclavicular Joint

    Directory of Open Access Journals (Sweden)

    Salma Eltoum Elamin

    2013-01-01

    Full Text Available Acromioclavicular (AC joint injuries account for approximately 3–5% of shoulder girdle injuries (Rockwood et al., 1998. Depending on severity of injury and direction of displacement these are classified using Rockwood classification system for AC joint dislocation. We present an unusual case presenting with locked superior dislocation of the AC joint highlighting the presentation and subsequent successful surgical management of such case. To our knowledge this has not been reported previously in literature.

  8. Reperfusion hemorrhage following superior mesenteric artery stenting.

    LENUS (Irish Health Repository)

    Moore, Michael

    2012-02-03

    Percutaneous transluminal angioplasty and stent placement is now an established treatment option for chronic mesenteric ischemia and is associated with low mortality and morbidity rates. We present a case of reperfusion hemorrhage complicating endovascular repair of superior mesenteric artery stenosis. Although a recognized complication following repair of carotid stenosis, hemorrhage has not previously been reported following mesenteric endovascular reperfusion. We describe both spontaneous cessation of bleeding and treatment with coil embolization.

  9. [Mitral surgery by superior biatrial septotomy].

    Science.gov (United States)

    Saade, A; Delepine, G; Lemaitre, C; Baehrel, B

    1995-01-01

    The superior biatrial septotomy approach consists of two semicircular right atrial and septal incisions joined at the superior end of the interatrial septum and extended across the dome of the left atrium, allowing exposure of the mitral valve by reflecting the ventricular side using stay sutures. From 1991 to 1993, 81 patients underwent mitral valve surgery by this technic. Mitral valve operation was combined with other cardiac procedures in 30 patients (37%) and was performed as a second operation in 21 patients (25.9%). Duration of cardiopulmonary bypass and aortic occlusion was not significantly different from that of patients operated via a conventional left atrial approach. The five hospital deaths (6.2%) were not related to this operative approach. Only 2 patients (3.3%) with preoperative in sinus rythm were discharged in atrial fibrillation after operation. In one patient (1.6%), atrioventricular block appeared at late follow-up. There were no cases of bleeding, atrioventricular nodal dysfunction or intra-atrial shunting related to the approach. This approach provides excellent exposure of the mitral valve even in unfavorable situations such as a small left atrium, dense adhesions from previous procedures or a previously implanted aortic prosthesis, without damage to various cardiac structures due to excessive traction. No retractor or vena cava repair are required. These data support a wide application of the superior biatrial septotomy approach in mitral valve surgery.

  10. Current-voltage characteristic of parallel-plane ionization chamber with inhomogeneous ionization

    Energy Technology Data Exchange (ETDEWEB)

    Stoyanov, D G [Faculty of Engineering and Pedagogy in Sliven, Technical University of Sofia, 59, Bourgasko Shaussee Blvd, 8800 Sliven (Bulgaria)

    2007-08-15

    The balances of particles and charges in the volume of parallel-plane ionization chamber are considered. Differential equations describing the distribution of current densities in the chamber volume are obtained. As a result of the differential equations solution an analytical form of the current-voltage characteristic of parallel-plane ionization chamber with inhomogeneous ionization in the volume is obtained.

  11. Current-voltage characteristic of parallel-plane ionization chamber with inhomogeneous ionization

    CERN Document Server

    Stoyanov, Dimitar G

    2007-01-01

    The balances of particles and charges in the volume of parallel-plane ionization chamber are considered. Differential equations describing the distribution of current densities in the chamber volume are obtained. As a result of the differential equations solution an analytical form of the current-voltage characteristic of parallel-plane ionization chamber with inhomogeneous ionization in the volume is got.

  12. IONIZED NITROGEN AT HIGH REDSHIFT

    Energy Technology Data Exchange (ETDEWEB)

    Decarli, R.; Walter, F. [Max-Planck Institut fuer Astronomie, Koenigstuhl 17, D-69117 Heidelberg (Germany); Neri, R.; Cox, P. [IRAM, 300 rue de la piscine, F-38406 Saint-Martin d' Heres (France); Bertoldi, F. [Argelander Institute for Astronomy, University of Bonn, Auf dem Huegel 71, D-53121 Bonn (Germany); Carilli, C. [NRAO, Pete V. Domenici Array Science Center, P.O. Box O, Socorro, NM 87801 (United States); Kneib, J. P. [Laboratoire d' Astrophysique de Marseille, Observatoire d' Astronomie Marseille-Provence, BP 8, F-13376 Marseille (France); Lestrade, J. F. [Observatoire de Paris, CNRS, 61 Av. de l' Observatoire, F-75014 Paris (France); Maiolino, R. [INAF-Osservatorio Astronomico di Roma, via di Frascati 33, I-00040 Monte Porzio Catone (Italy); Omont, A. [Institut d' Astrophysique de Paris, UPMC and CNRS, 98bis Bld. Arago, F-75014 Paris (France); Richard, J. [CRAL, Observatoire de Lyon, Universite Lyon 1, 9 Avenue Ch. Andre, F-69561 Saint Genis Laval Cedex (France); Riechers, D. [Astronomy Department, Caltech, 1200 East California Boulevard, Pasadena, CA 91125 (United States); Thanjavur, K. [Canada-France-Hawaii Telescope Corporation, HI 96743 (United States); Weiss, A., E-mail: decarli@mpia.de [Max-Planck-Institut fuer Radioastronomie, Auf dem Huegel 69, D-53121 Bonn (Germany)

    2012-06-10

    We present secure [N II]{sub 205{mu}m} detections in two millimeter-bright, strongly lensed objects at high redshift, APM 08279+5255 (z = 3.911) and MM 18423+5938 (z = 3.930), using the IRAM Plateau de Bure Interferometer. Due to its ionization energy [N II]{sub 205{mu}m} is a good tracer of the ionized gas phase in the interstellar medium. The measured fluxes are S([N II]{sub 205{mu}m}) = (4.8 {+-} 0.8) Jy km s{sup -1} and (7.4 {+-} 0.5) Jy km s{sup -1}, respectively, yielding line luminosities of L([N II]{sub 205{mu}m}) = (1.8 {+-} 0.3) Multiplication-Sign 10{sup 9} {mu}{sup -1} L{sub Sun} for APM 08279+5255 and L([N II]{sub 205{mu}m}) = (2.8 {+-} 0.2) Multiplication-Sign 10{sup 9} {mu}{sup -1} L{sub Sun} for MM 18423+5938. Our high-resolution map of the [N II]{sub 205{mu}m} and 1 mm continuum emission in MM 18423+5938 clearly resolves an Einstein ring in this source and reveals a velocity gradient in the dynamics of the ionized gas. A comparison of these maps with high-resolution EVLA CO observations enables us to perform the first spatially resolved study of the dust continuum-to-molecular gas surface brightness ({Sigma}{sub FIR}{proportional_to}{Sigma}{sup N}{sub CO}, which can be interpreted as the star formation law) in a high-redshift object. We find a steep relation (N = 1.4 {+-} 0.2), consistent with a starbursting environment. We measure a [N II]{sub 205{mu}m}/FIR luminosity ratio in APM 08279+5255 and MM 18423+5938 of 9.0 Multiplication-Sign 10{sup -6} and 5.8 Multiplication-Sign 10{sup -6}, respectively. This is in agreement with the decrease of the [N II]{sub 205{mu}m}/FIR ratio at high FIR luminosities observed in local galaxies.

  13. Field ionization of free helium atoms: Correlation between the kinetic energy of ionized atoms and probability of their field ionization

    Energy Technology Data Exchange (ETDEWEB)

    Piskur, J.; Borg, L. [Institute of Experimental Physics, Graz University of Technology, Petersgasse 16, 8010 Graz (Austria); Stupnik, A.; Leisch, M. [Institute of Solid State Physics, Graz University of Technology, Petersgasse 16, 8010 Graz (Austria); Ernst, W.E. [Institute of Experimental Physics, Graz University of Technology, Petersgasse 16, 8010 Graz (Austria); Holst, B. [Institute of Experimental Physics, Graz University of Technology, Petersgasse 16, 8010 Graz (Austria)], E-mail: bodil@cantab.net

    2008-05-15

    In this paper the correlation between the kinetic energy of helium atoms and the probability of field ionization is investigated by exploiting the narrow velocity distribution of supersonic molecular beams. Field ionization measurements were carried out on supersonic helium beams at 298 K and 95 K corresponding to energies of about 65 meV and 20 meV, respectively, for the individual atoms. The field ionization was performed with a tungsten tip, radius of curvature 12 nm, kept at room temperature. The ionization probability was found to increase by about a factor 10 when the beam was cooled from 298 K to 95 K. The results presented in this paper are of importance for improving the understanding of field ionization and for the development of a new detector for helium and other molecular beams.

  14. Field ionization of free helium atoms: Correlation between the kinetic energy of ionized atoms and probability of their field ionization

    Science.gov (United States)

    Piskur, J.; Borg, L.; Stupnik, A.; Leisch, M.; Ernst, W. E.; Holst, B.

    2008-05-01

    In this paper the correlation between the kinetic energy of helium atoms and the probability of field ionization is investigated by exploiting the narrow velocity distribution of supersonic molecular beams. Field ionization measurements were carried out on supersonic helium beams at 298 K and 95 K corresponding to energies of about 65 meV and 20 meV, respectively, for the individual atoms. The field ionization was performed with a tungsten tip, radius of curvature 12 nm, kept at room temperature. The ionization probability was found to increase by about a factor 10 when the beam was cooled from 298 K to 95 K. The results presented in this paper are of importance for improving the understanding of field ionization and for the development of a new detector for helium and other molecular beams.

  15. Late Spectral Evolution of SN 1987A: I. Temperature and Ionization

    OpenAIRE

    Kozma, Cecilia; Fransson, Claes

    1997-01-01

    The temperature and ionization of SN 1987A is modeled between 200 and 2000 days in its nebular phase, using a time-dependent model. We include all important elements, as well as the primary composition zones in the supernova. The energy input is provided by radioactive decay of Co-56, Co-57, and Ti-44. The thermalization of the resulting gamma-rays and positrons is calculated by solving the Spencer-Fano equation. Both the ionization and the individual level populations are calculated time-dep...

  16. Superior mesenteric artery compression syndrome - case report

    Directory of Open Access Journals (Sweden)

    Paulo Rocha França Neto

    2011-12-01

    Full Text Available Superior mesenteric artery syndrome is an entity generally caused by the loss of the intervening mesenteric fat pad, resulting in compression of the third portion of the duodenum by the superior mesenteric artery. This article reports the case of a patient with irremovable metastatic adenocarcinoma in the sigmoid colon, that evolved with intense vomiting. Intestinal transit was carried out, which showed important gastric dilation extended until the third portion of the duodenum, compatible with superior mesenteric artery syndrome. Considering the patient's nutritional condition, the medical team opted for the conservative treatment. Four months after the surgery and conservative measures, the patient did not present vomiting after eating, maintaining previous weight. Superior mesenteric artery syndrome is uncommon and can have unspecific symptoms. Thus, high suspicion is required for the appropriate clinical adjustment. A barium examination is required to make the diagnosis. The treatment can initially require gastric decompression and hydration, besides reversal of weight loss through adequate nutrition. Surgery should be adopted only in case of clinical treatment failure.A síndrome da artéria mesentérica superior é uma entidade clínica causada geralmente pela perda do tecido adiposo mesentérico, resultando na compressão da terceira porção do duodeno pela artéria mesentérica superior. Esse artigo relata o caso clínico de uma paciente portadora de adenocarcinoma de cólon sigmoide metastático irressecável, que evoluiu com vômitos incoercíveis. Realizou-se, então, trânsito intestinal que evidenciou dilatação gástrica importante, que se prolongava até a terceira porção duodenal, quadro radiológico compatível com pinçamento da artéria mesentérica superior. Diante da condição nutricional da paciente, foi optado por iniciar medidas conservadoras (porções alimentares pequenas e mais frequentes, além de dec

  17. Benchmarking Ionizing Space Environment Models

    Science.gov (United States)

    Bourdarie, S.; Inguimbert, C.; Standarovski, D.; Vaillé, J.-R.; Sicard-Piet, A.; Falguere, D.; Ecoffet, R.; Poivey, C.; Lorfèvre, E.

    2017-08-01

    In-flight feedback data are collected, such as displacement damage doses, ionizing doses, and cumulated Single Event upset (SEU) on board various space vehicles and are compared to predictions performed with: 1) proton measurements performed with spectrometers data on board the same spacecraft if any and 2) protons spectrum predicted by the legacy AP8min model and the AP9 and Onera Proton Altitude Low models. When an accurate representation of the 3-D spacecraft shielding as well as appropriate ground calibrations are considered in the calculations, such comparisons provide powerful metrics to investigate engineering model accuracy. To describe >30 MeV trapped protons fluxes, the AP8 min model is found to provide closer predictions to observations than AP9 V1.30.001 (mean and perturbed mean).

  18. Ionization cooling ring for muons

    Directory of Open Access Journals (Sweden)

    R. Palmer

    2005-06-01

    Full Text Available Practical ionization cooling rings could lead to lower cost or improved performance in neutrino factory or muon collider designs. The ring modeled here uses realistic three-dimensional fields. The performance of the ring compares favorably with the linear cooling channel used in the second U.S. Neutrino Factory Study. The normalized 6D emittance of an ideal ring is decreased by a factor of approximately 240, compared with a factor of only 15 for the linear channel. We also examine such real-world effects as windows on the absorbers and rf cavities and leaving empty lattice cells for injection and extraction. For realistic conditions the ring decreases the normalized 6D emittance by a factor of 49.

  19. Ionization in nearby interstellar gas

    Science.gov (United States)

    Frisch, P. C.; Welty, D. E.; York, D. G.; Fowler, J. R.

    1990-01-01

    Due to dielectric recombination, neutral magnesium represents an important tracer for the warm low-density gas around the solar system. New Mg I 2852 absorption-line data from IUE are presented, including detections in a few stars within 40 pc of the sun. The absence of detectable Mg I in Alpha CMa and other stars sets limits on the combined size and electron density of the interstellar cloud which gives rise to the local interstellar wind. For a cloud radius greater than 1 pc and density of 0.1/cu cm, the local cloud has a low fractional ionization, n(e)/n(tot) less than 0.05, if magnesium is undepleted, equilibrium conditions prevail, the cloud temperature is 11,750 K, and 80 percent of the magnesium in the sightline is Mg II.

  20. Ionization in nearby interstellar gas

    Energy Technology Data Exchange (ETDEWEB)

    Frisch, P.C.; Welty, D.E.; York, D.G.; Fowler, J.R. (Chicago Univ., IL (USA) New Mexico State Univ., Las Cruces (USA))

    1990-07-01

    Due to dielectric recombination, neutral magnesium represents an important tracer for the warm low-density gas around the solar system. New Mg I 2852 absorption-line data from IUE are presented, including detections in a few stars within 40 pc of the sun. The absence of detectable Mg I in Alpha CMa and other stars sets limits on the combined size and electron density of the interstellar cloud which gives rise to the local interstellar wind. For a cloud radius greater than 1 pc and density of 0.1/cu cm, the local cloud has a low fractional ionization, n(e)/n(tot) less than 0.05, if magnesium is undepleted, equilibrium conditions prevail, the cloud temperature is 11,750 K, and 80 percent of the magnesium in the sightline is Mg II. 85 refs.

  1. Bystander Effects of Ionizing Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Little, John B. [Harvard T.H. Chan School of Public Health, Boston, MA (United States). Dept. of Genetics and Complex Diseases

    2017-01-17

    The objectives of this grant renewal are to provide administrative support and travel funds to allow the continued participation of the principal investigator (Dr. John B. Little) as an advisor to research initiated by several research fellows from his laboratory. The actual research will be carried out under the direction of Dr. Hatsumi Nagasawa with the collaboration of Dr. Joel Bedford at the Colorado State University, and by Drs. Edouard Azzam and Sonia de Toledo at the University of Medicine and Dentistry of New Jersey. Dr. Little will advise on the planning of experiments and development of experimental protocols, the analysis of data, and the preparation of manuscripts for publication. The Specific Aims for several of the planned experiments include: 1) to extend studies of the role of recombinational repair in the bystander effect by examining other genes in this pathway and cell lines deficient in excision repair; 2) to continue studies to determine the nature of the damage signal transmitted to bystander cells including the expression of several connexins in the bystander response, and the extent to which the enhanced oxidative metabolism observed in bystander cells may relate to the nature of the transmitted bystander signal; 3) to utilize a genome-wide approach to examine the genetic basis for the hypersensitivity to ionization we have observed in unaffected parents of patients with hereditary retinoblastoma, as well as from a group of a apparently normal individuals that show similar radiosensitivity; 4) to complete studies concerning the induction of high frequencies of cells with massive chromosome damage in clonal derivatives of p53 and p21 knockout mouse cell lines; in particular to examine the role of telomere changes in this phenomenon. Overall, the results of these studies should enhance our understanding of the risk of low dose exposures to ionizing radiation, including human populations to residential radon as well as occupational exposures.

  2. Ionization penalty in nonlinear Raman neuroimaging.

    Science.gov (United States)

    Voronin, Aleksandr A; Fedotov, Ilya V; Doronina-Amitonova, Lyubov V; Ivashkina, Olga I; Zots, Marina A; Fedotov, Andrei B; Anokhin, Konstantin V; Zheltikov, Aleksei M

    2011-02-15

    Light-assisted ionization accompanying coherent anti-Stokes Raman scattering (CARS) of ultrashort laser pulses in brain tissue is shown to manifest itself in a detectable blueshift of the anti-Stokes signal. This blueshift can serve as an indicator of ionization processes in CARS-based neuroimaging.

  3. An ionization chamber with magnetic levitated electrodes

    CERN Document Server

    Kawaguchi, T

    1999-01-01

    A new type of ionization chamber which has magnetically levitated electrodes has been developed. The electrodes are supplied voltages for the repelling of ions by a battery which is also levitated with the electrodes. The characteristics of this ionization chamber are investigated in this paper.

  4. Multiorbital tunneling ionization of the CO molecule

    CERN Document Server

    Wu, J; Kunitski, M; Meckel, M; Voss, S; Sann, H; Kim, H; Jahnke, T; Czasch, A; Dörner, R

    2012-01-01

    We coincidently measure the molecular frame photoelectron angular distribution and the ion sum-momentum distribution of single and double ionization of CO molecules by using circularly and elliptically polarized femtosecond laser pulses, respectively. The orientation dependent ionization rates for various kinetic energy releases allow us to individually identify the ionizations of multiple orbitals, ranging from the highest occupied to the next two lower-lying molecular orbitals for various channels observed in our experiments. Not only the emission of a single electron, but also the sequential tunneling dynamics of two electrons from multiple orbitals are traced step by step. Our results confirm that the shape of the ionizing orbitals determine the strong laser field tunneling ionization in the CO molecule, whereas the linear Stark effect plays a minor role.

  5. MHD power generation with fully ionized seed

    Energy Technology Data Exchange (ETDEWEB)

    Yamasaki, H.; Shioda, S.

    1977-01-01

    Recovery of power density in the regime of fully ionized seed has been demonstrated experimentally using an MHD disk generator with the effective Hall parameter up to 5.0 when the seed was fully ionized. The experiments were conducted with a shock-heated and potassium-seeded argon plasma under the following conditions: stagnation gas pressure = 0.92 atm, stagnation gas temperature = 2750 K, flow Mach number = 2.5, and seed fraction = 1.4 x 10/sup -5/. Measurements of electron-number density and spectroscopic observations of both potassium and argon lines confirmed that the recovery of power output was due to the reduction of ionization instability. This fact indicates that the successful operation of a disk generator utilizing nonequilibrium ionization seems to be possible and that the suppression of ionization instability can also provide higher adiabatic efficiency. Furthermore, the lower seed fraction offers technological advantages related to seed problems.

  6. Thermal comfort

    CSIR Research Space (South Africa)

    Osburn, L

    2010-01-01

    Full Text Available Thermal comfort is influenced by environmental parameters as well as other influences including asymmetric heating and cooling conditions. Additionally, some aspects of thermal comfort may be exploited so as to enable a building to operate within a...

  7. 非接触热解析封闭式低温等离子体电离源质谱法快速分析3种农药残留%Rapid Analysis of Three Kinds of Pesticide Residues by Non-contact Thermal Desorbing and Closing Low Temperature Plasma Ionization Mass Spectrometry

    Institute of Scientific and Technical Information of China (English)

    苏明扬; 李海洋; 侯可勇; 黄泽健; 江游; 陈文东; 陈平; 蒋吉春; 赵无垛; 裴克梅

    2014-01-01

    A new method was established for the direct, rapid and quantitative analysis of pesticide residues, dimethoate chlorothalonil and malathion by low temperature plasma ( LTP) ionization miniature ion trap mass spectrometer. The LTP ionization probe and sample inlet of ion trap mass spectrometry were enclosed in a metal cavity. With non-contact heating, the samples placed on the sample platform were desorbed into gaseous phase and ionized by LTP ionization probe. The results showed that closed ionization had an edge over the opened ionization. The quantitative analysis of 3 pesticides within the range of 0. 5-10 mg/L was realized by optimizing heating time and flow rate of air, and the relative standard deviations of signal intensity is less than 11%. LODs of pesticide, which were obtained within 5 s, were as low as several hundred pictograms. The results showed that the method could be used for the analysis of pesticide residue on green and organic fruits or vegetables.%利用低温等离子体电离源微型离子阱质谱建立了一种常压离子化质谱直接、快速、定量分析农药残留的新方法。低温等离子体电离源与质谱进样口处于封闭金属腔体内部,在负离子探测模式下,将样品放置于低温等离子体电离源前的采样平台上,利用卤素灯快速无接触热解析样品。结果表明,封闭离子源更具优势,通过对加热时间、辅助气流流量等条件的优化,实现了对3种农药在0.5~10 mg/L范围内的定量分析,相对标准偏差控制在11%左右,5 s内的样品检出限均在pg量级。该检测方法无需样品前处理,样品可直接检测,分析时间快,有望广泛应用于有机和绿色果蔬中农药残留的快速检测。

  8. Exploring the word superiority effect using TVA

    DEFF Research Database (Denmark)

    Starrfelt, Randi

    Words are made of letters, and yet sometimes it is easier to identify a word than a single letter. This word superiority effect (WSE) has been observed when written stimuli are presented very briefly or degraded by visual noise. It is unclear, however, if this is due to a lower threshold for perc...... simultaneously we find a different pattern: In a whole report experiment with six stimuli (letters or words), letters are perceived more easily than words, and this is reflected both in perceptual processing speed and short term memory capacity....

  9. de educación media superior

    Directory of Open Access Journals (Sweden)

    Enrique Cerón Ferrer

    2007-01-01

    Full Text Available El trabajo presenta los resultados obtenidos en relación al conocimiento y manejo que sobre matemáticas tienen los estudiantes de educación media superior, de los Centros de Estudios Tecnológicos y de Servicios del Distrito Federal, de diferentes carreras que se imparten en estos centros escolares, durante el año 2005. El instrumento de análisis es un cuestionario que contestaron los alumnos, la metodología utilizada es de tipo longitudinal y comparativa.

  10. Experimental comparison of models for ultrafast impact ionization is silicon

    DEFF Research Database (Denmark)

    Tarekegne, Abebe Tilahun; Iwaszczuk, Krzysztof; Jepsen, Peter Uhd

    2016-01-01

    We compare experimentally the exponential and quadratic (Keldysh formula) impact ionization models using THz induced impact ionization in silicon. We demonstrate that the exponential model offers the best description of impact ionization process for ultrashort electric filed pulses.......We compare experimentally the exponential and quadratic (Keldysh formula) impact ionization models using THz induced impact ionization in silicon. We demonstrate that the exponential model offers the best description of impact ionization process for ultrashort electric filed pulses....

  11. Ionization Cooling using Parametric Resonances

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Rolland P.

    2008-06-07

    Ionization Cooling using Parametric Resonances was an SBIR project begun in July 2004 and ended in January 2008 with Muons, Inc., (Dr. Rolland Johnson, PI), and Thomas Jefferson National Accelerator Facility (JLab) (Dr. Yaroslav Derbenev, Subcontract PI). The project was to develop the theory and simulations of Parametric-resonance Ionization Cooling (PIC) so that it could be used to provide the extra transverse cooling needed for muon colliders in order to relax the requirements on the proton driver, reduce the site boundary radiation, and provide a better environment for experiments. During the course of the project, the theoretical understanding of PIC was developed and a final exposition is ready for publication. Workshops were sponsored by Muons, Inc. in May and September of 2007 that were devoted to the PIC technique. One outcome of the workshops was the interesting and somewhat unexpected realization that the beam emittances using the PIC technique can get small enough that space charge forces can be important. A parallel effort to develop our G4beamline simulation program to include space charge effects was initiated to address this problem. A method of compensating for chromatic aberrations by employing synchrotron motion was developed and simulated. A method of compensating for spherical aberrations using beamline symmetry was also developed and simulated. Different optics designs have been developed using the OptiM program in preparation for applying our G4beamline simulation program, which contains all the power of the Geant4 toolkit. However, no PIC channel design that has been developed has had the desired cooling performance when subjected to the complete G4beamline simulation program. This is believed to be the consequence of the difficulties of correcting the aberrations associated with the naturally large beam angles and beam sizes of the PIC method that are exacerbated by the fringe fields of the rather complicated channel designs that have been

  12. Pancreaticoduodenectomy with early superior mesenteric artery dissection

    Institute of Scientific and Technical Information of China (English)

    Yu-Fei Xu; Zuo-Jin Liu; Jian-Ping Gong

    2010-01-01

    BACKGROUND: Pancreatic adenocarcinoma remains the fourth leading cause of cancer-related death and is one of the most aggressive human tumors. At present, surgical resection is the only potentially curative treatment. Early neck division is inadequate when invasion of the superior mesenteric artery (SMA) is suspected or in cases of replaced or accessory right hepatic artery. Malignant periampullary tumors often invade retroperitoneal peripancreatic tissues and a positive resection margin is associated with a poor long-term survival. DATA SOURCES: English-language medical databases, PubMed, ELSEVIER and SPRINGERLINK, were searched for articles on"posterior approach pancreaticoduodenectomy","superior mesenteric artery ifrst approach", "retroperitoneal tissue","hanging maneuver", and related topics. RESULTS:The modiifcation allowed the surgeon to early identify the nonresectability of a replaced right hepatic artery if present, enabling complete dissection of the right side of the SMA and portal vein as well as complete excision of the retroportal pancreatic lamina. CONCLUSION: Pancreaticoduodenectomy with early retro-pancreatic dissection is a useful and safe technical variant, which is indicated for the improvement of the safety and curative effect of the procedure.

  13. Radiation treatment of superior sulcus lung carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Millar, J.; Ball, D.; Worotniuk, V.; Smith, J.; Crennan, E.; Bishop, M. [Peter MacCallum Cancer Inst., East Melbourne, VIC (Australia)

    1996-02-01

    The survival of patients with superior sulcus lung carcinoma and the effects of treatment were reviewed. From a prospective database of 4123 consecutive new patients with lung carcinoma, 131 (3.2%) cases of superior sulcus lung carcinoma were identified. Seventy-four patients were planned to receive radiation with palliative intent, 53 radical radiotherapy and one was observed only. The remaining three patients, with small-cell carcinoma, were treated with chemotherapy with or without radiotherapy. Of the 53 radically treated patients, nine were treated with pre-operative radiation prior to intended radical resection. Analysis was carried out on the effect on survival of performance status, nodal involvement, weight loss, vertebral body or rib involvement, treatment intent and radical combined modality treatment compared with radical radiation alone. The estimated median survival for the whole group was 7.6 months; for those treated radically it was 18.3 months, while for the palliatively treated patients it was 3.7 months. Radically treated patients with no initial nodal involvement had an estimated median survival of 22 months, while radically treated patients with nodal involvement had an estimated median survival of 8.4 months (P = 0.003). There were no statistically significant differences in survival between radically treated patients grouped according to initial weight loss, performance status, or vertebral body and rib involvement. Patients treated with pre-operative radiation did not survive significantly longer than patients treated with radiation alone, although the numbers are small. 33 refs., 2 tabs., 4 figs.

  14. Studies on zooplankton of Lago Paione Superiore

    Directory of Open Access Journals (Sweden)

    Patrizia COMOLI

    1999-08-01

    Full Text Available We report here the results of a three year study on the zooplankton of Lago Paione Superiore, an acid sensitive lake above the tree line in the Italian Alps. The research was carried out within MOLAR, an EC-founded Project on “Measuring and Modeling the dynamic response of remote mountain lakes ecosystems to environmental change”. This study comes after a series of investigations on the effects of acidification, in which we documented the changes occurred with decreasing water pHs, by comparing the recent situation with that in the literature of the 40s, and reconstructed the beginning of anthropogenic disturbance through an analysis of the past cladocera assemblages archived in the lake sediments. A characteristic pattern in seasonal periodicity is a transition from a community dominated by small zooplankton (August to a community where the large particle-feeder Daphnia longispina dominates. This is a typical pattern observed in fishless, copepod-cladocera lakes. Regardless from which food is able to exploit, Daphnia population of Lago Paione Superiore is composed by well-fed organisms, visually rich in lipids, able to produce more than one generation/ year of parthenogenetic females at density levels which are rather high in an oligotrophic high mountain lake.

  15. Electrospray ionization and matrix assisted laser desorption/ionization mass spectrometry: powerful analytical tools in recombinant protein chemistry

    DEFF Research Database (Denmark)

    Andersen, Jens S.; Svensson, B; Roepstorff, P

    1996-01-01

    Electrospray ionization and matrix assisted laser desorption/ionization are effective ionization methods for mass spectrometry of biomolecules. Here we describe the capabilities of these methods for peptide and protein characterization in biotechnology. An integrated analytical strategy is presen......Electrospray ionization and matrix assisted laser desorption/ionization are effective ionization methods for mass spectrometry of biomolecules. Here we describe the capabilities of these methods for peptide and protein characterization in biotechnology. An integrated analytical strategy...

  16. Electron impact single ionization of copper

    Indian Academy of Sciences (India)

    L K Jha; O P Roy; B N Roy

    2000-09-01

    Electron impact single ionization cross sections of copper have been calculated in the binary encounter approximation using accurate expression for as given by Vriens and Hartree–Fock momentum distribution for the target electron. The BEA calculation based on the usual procedure does not show satisfactory agreement with experiment in this case but a striking modification is found to be successful in explaining the experimental observations. The discrepancy is linked with the ionization of the 310 electrons and probably effective single ionization does not take place from 3 shell of copper leading to smaller values of experimental cross sections.

  17. Leukemia and ionizing radiation revisited

    Energy Technology Data Exchange (ETDEWEB)

    Cuttler, J.M. [Cuttler & Associates Inc., Vaughan, Ontario (Canada); Welsh, J.S. [Loyola University-Chicago, Dept. or Radiation Oncology, Stritch School of Medicine, Maywood, Illinois (United States)

    2016-03-15

    A world-wide radiation health scare was created in the late 19508 to stop the testing of atomic bombs and block the development of nuclear energy. In spite of the large amount of evidence that contradicts the cancer predictions, this fear continues. It impairs the use of low radiation doses in medical diagnostic imaging and radiation therapy. This brief article revisits the second of two key studies, which revolutionized radiation protection, and identifies a serious error that was missed. This error in analyzing the leukemia incidence among the 195,000 survivors, in the combined exposed populations of Hiroshima and Nagasaki, invalidates use of the LNT model for assessing the risk of cancer from ionizing radiation. The threshold acute dose for radiation-induced leukemia, based on about 96,800 humans, is identified to be about 50 rem, or 0.5 Sv. It is reasonable to expect that the thresholds for other cancer types are higher than this level. No predictions or hints of excess cancer risk (or any other health risk) should be made for an acute exposure below this value until there is scientific evidence to support the LNT hypothesis. (author)

  18. Cochlear implant outcomes in patients with superior canal dehiscence

    NARCIS (Netherlands)

    Puram, Sidharth V.; Roberts, Daniel S.; Niesten, Marlien E F; Dilger, Amanda E.; Lee, Daniel J.

    2015-01-01

    Objective: To determine whether adult cochlear implant (CI) users with superior canal dehiscence syndrome (SCDS) or asymptomatic superior semicircular canal dehiscence (SCD) have different surgical, vestibular, and audiologic outcomes when compared to CI users with normal temporal bone anatomy. Meth

  19. The Superior Transvelar Approach to the Fourth Ventricle and Brainstem

    OpenAIRE

    Ezer, Haim; Banerjee, Anirban Deep; Bollam, Papireddy; Guthikonda, Bharat; Nanda, Anil

    2012-01-01

    Objective The superior transvelar approach is used to access pathologies located in the fourth ventricle and brainstem. The surgical path is below the venous structures, through the superior medullary velum. Following splitting the tentorial edge, near the tentorial apex, the superior medullary velum is split in the cerebello-mesencephalic fissure. Using the supracerebellar infratentorial, transtentorial or parietal interhemispheric routes, the superior medullary velum is approached. Splittin...

  20. RILIS-ionized mercury and tellurium beams at ISOLDE CERN

    Energy Technology Data Exchange (ETDEWEB)

    Day Goodacre, T., E-mail: thomas.day.goodacre@cern.ch [CERN (Switzerland); Billowes, J. [The University of Manchester, School of Physics and Astronomy (United Kingdom); Chrysalidis, K. [CERN (Switzerland); Fedorov, D. V. [Petersburg Nuclear Physics Institute (Russian Federation); Fedosseev, V. N.; Marsh, B. A. [CERN (Switzerland); Molkanov, P. L. [Petersburg Nuclear Physics Institute (Russian Federation); Rossel, R. E.; Rothe, S.; Seiffert, C. [CERN (Switzerland); Wendt, K. D. A. [Johannes Gutenberg Universität, Institut für Physik (Germany)

    2017-11-15

    This paper presents the results of ionization scheme development for application at the ISOLDE Resonance Ionization Laser Ion Source (RILIS). Two new ionization schemes for mercury are presented: a three-step three-resonance ionization scheme, ionizing via an excitation to a Rydberg level and a three-step two-resonance ionization scheme, with a non-resonant final step to the ionization continuum that corresponded to a factor of four higher ionization efficiency. The efficiency of the optimal mercury ionization scheme was measured, together with the efficiency of a new three-step three resonance ionization scheme for tellurium. The efficiencies of the mercury and tellurium ionization schemes were determined to be 6 % and >18 % respectively.

  1. 14 CFR 385.7 - Exercise of authority by superiors.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Exercise of authority by superiors. 385.7... Exercise of authority by superiors. Any assignment of authority to a staff member other than the Chief... Department's principle of management responsibility, the superior may choose to exercise the assigned power...

  2. 76 FR 51876 - Medical Devices; Ophthalmic Devices; Classification of the Eyelid Thermal Pulsation System

    Science.gov (United States)

    2011-08-19

    ... validate electromagnetic compatibility (EMC) and safety of exposure to non-ionizing radiation; (2) Design... Safety Testing. Electromagnetic interference Electromagnetic Compatibility (EMC) Testing; Labeling. Thermal damage Temperature Performance Testing. Mechanical damage Pressure Performance...

  3. Superiority: China Mobile in the competition

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The market share between China Mobile and China Unicom has stabilized since 2002.It is found that China Mobile has the superiority in the competition, for example, the scissors movement between its revenue and cost indicates that it has a strong profit generating ability and there is enough room for it to reduce the price.The ratio between its price (marginal income) and marginal cost indicates that there is a very distant limit for it to reduce the price.Its demand is obviously flexible with the price, but it does not use the price weapon abundantly.The reason for the stabilization of the market is that China Mobile withdrew from the competition.

  4. MRI manifestations of enlarged superior ophthalmic vein

    Institute of Scientific and Technical Information of China (English)

    WEI Rui-li; MA Xiao-ye; CAI Ji-ping; ZHU Huang

    2002-01-01

    Objective:To assess MRI in the evaluation of enlarged superior ophthalmic vein (SOV). Methods: MRI manifestations and etiology of forty-six patients with enlarged SOV were analyzed. Results: SOV enlargement was noted to occur in carotid-cavernous fistula, ophthalmic Graves'disease, Tolosa-Hunt syndrome, inflammation at the apex of the orbit, orbital pseudotumor and thrombosis of cavernous sinus. The dilated vein appeared as signal void tubular shadows on both T1 and T2 weighted images. The diameter of the enlarged vein was 3.5-6.0 mm. Extraocular muscle enlargement, orbital pathologies, enlarged carotid cavernous sinus etc were also revealed by MRI. Conclusion: The dilated SOV may be well demonstrated by MRI. The etiological diagnosis of enlarged SOV can be made in combination with the associated findings.

  5. Lightning activity during the 1999 Superior derecho

    Science.gov (United States)

    Price, Colin G.; Murphy, Brian P.

    2002-12-01

    On 4 July 1999, a severe convective windstorm, known as a derecho, caused extensive damage to forested regions along the United States/Canada border, west of Lake Superior. There were 665,000 acres of forest destroyed in the Boundary Waters Canoe Area Wilderness (BWCAW) in Minnesota and Quetico Provincial Park in Canada, with approximately 12.5 million trees blown down. This storm resulted in additional severe weather before and after the occurrence of the derecho, with continuous cloud-to-ground (CG) lightning occurring for more than 34 hours during its path across North America. At the time of the derecho the percentage of positive cloud-to-ground (+CG) lightning measured by the Canadian Lightning Detection Network (CLDN) was greater than 70% for more than three hours, with peak values reaching 97% positive CG lightning. Such high ratios of +CG are rare, and may be useful indicators of severe weather.

  6. Analgesia em modelo animal superior para ortopedia

    OpenAIRE

    Oliveira MT, Maria Teresa; Potes, José Alberto; Queiroga, Cristina; Castro, José António; Pereira, Alfredo; Reis, Joana

    2015-01-01

    O teste de novos biomateriais para aplicações clínicas em ortopedia, ou noutras áreas da medicina, em modelos animais vivos e sencientes, em prol do benefício humano, deve ser objecto de planeamento cuidado e ponderado, dado o conflito ético que se coloca. Compete-nos a nós, enquanto investigadores, garantir que as condições de vida, saúde e bem-estar são asseguradas. O uso de ovinos como modelo superior pré-clínico, para investigação em Ortopedia, tem-se evidenciado devido às suas caracterís...

  7. Superior vena cava syndrome in hemodialysis patient

    Directory of Open Access Journals (Sweden)

    Azeb Molhem

    2011-01-01

    Full Text Available Obstruction of blood flow in the superior vena cava (SVC results in symptoms and signs of SVC syndrome. SVC obstruction can be caused either by invasion or external compression of the SVC by contagious pathologic processes involving the right lung, lymph nodes, and other mediastinal structures, or by thrombosis of blood within the SVC. Occasionally, both mechanisms co-exist. We hereby report a case of a 28-year-old male, Saudi patient who was diagnosed with end-stage renal disease and was maintained on regular hemodiaysis via right jugular vein dual lumen catheter for ten months. Three years later, the patient presented with signs and symptoms suggestive of SVC obstruction that was successfully managed with SVC stenting.

  8. [Surgical treatment of superior thoracic outlet syndrome].

    Science.gov (United States)

    Gaibov, A D; Kakhorov, A Z; Sadriev, O N; Yunusov, Kh A

    2015-01-01

    The authors present immediate and long-term results of treatment of 117 patients with superior thoracic outlet syndrome (STOS). There were different reasons for compression of neu- rovascular fascicle in outlet of the thorax. The costaclavicular syndrome was a reason in 48 patients, additional cervical ribs had 36 patients. Skalenus syndrome was noted in 26 cases, rudimentary cervical ribs or hypertrophy of cervical vertebrae C7 had 7 patients. Raynaud's syndrome took place in 19 cases. The required volume of diagnostic procedures and surgical treatment of STOS were determined according to the cause of the syndrome. Differentiated approach to the different forms of STOS was used in relation to dominant symptoms of the disease and reasons for compression of neurovascular fascicle. This allowed getting positive results in majority of patients (90,4%) in long- term period.

  9. ANATOMIC RESEARCH OF SUPERIOR CLUNIAL NERVE TRAUMA

    Institute of Scientific and Technical Information of China (English)

    1999-01-01

    In order to find the mechanism of superior clunial nerve (SCN) trauma, we dissected and revealed SCN from 12 corpses (24 sides). Combining 100 sides of SCN trauma, we inspected the course of SCN, the relation between SCN and it's neighbour tissues with the situation of SCN when being subjected to force. We found that the following special anatomic characteristics and mechanical elements such as the course of SCN, it's turning angles, the bony fibrous tube at the iliac crest, the posterior layer of the lumbodorsal fascia and SCN neighbour adipose tissue, are the causes of external force inducing SCN trauma. The anatomic revealment is the guidance of SCN trauma treatment with edged needle.

  10. Superiorization: An optimization heuristic for medical physics

    CERN Document Server

    Herman, G T; Davidi, R; Censor, Y

    2012-01-01

    Purpose: To describe and mathematically validate the superiorization methodology, which is a recently-developed heuristic approach to optimization, and to discuss its applicability to medical physics problem formulations that specify the desired solution (of physically given or otherwise obtained constraints) by an optimization criterion. Methods: The underlying idea is that many iterative algorithms for finding such a solution are perturbation resilient in the sense that, even if certain kinds of changes are made at the end of each iterative step, the algorithm still produces a constraints-compatible solution. This property is exploited by using permitted changes to steer the algorithm to a solution that is not only constraints-compatible, but is also desirable according to a specified optimization criterion. The approach is very general, it is applicable to many iterative procedures and optimization criteria used in medical physics. Results: The main practical contribution is a procedure for automatically p...

  11. Effect of electronic excitation on high-temperature flows of ionized nitrogen and oxygen mixtures behind strong shock waves

    Science.gov (United States)

    Istomin, V. A.; Kustova, E. V.

    2016-11-01

    Strongly non-equilibrium flows of reacting five-component ionized mixtures of nitrogen (N2/N2+/N /N+/e-) and oxygen (O2/O2+/O /O+/e-) behind the plane shock wave are studied taking into account electronic degrees of freedom of both neutral and ionized species. The kinetic scheme includes non-equilibrium reactions of ionization, dissociation, recombination and charge-transfer. Two test cases corresponding to the spacecraft re-entry (Hermes and Fire II experiments) are considered; fluid-dynamic variables, transport coefficients and heat flux are calculated, and different contribution to the heat flux are analyzed. The effect of electronic excitation on the heat transfer is governed by the competition of diffusion and heat conduction; it becomes weak if diffusive processes prevail. An important role of thermal diffusion in ionized flows is emphasized. The influence of dissociation rates on the heat flux is assessed.

  12. A VUV Photoionization and Ab Initio Determination of the Ionization Energy of a Gas-Phase Sugar (Deoxyribose).

    Science.gov (United States)

    Ghosh, Debashree; Golan, Amir; Takahashi, Lynelle K; Krylov, Anna I; Ahmed, Musahid

    2012-01-05

    The ionization energy of gas-phase deoxyribose was determined using tunable vacuum ultraviolet synchrotron radiation coupled to an effusive thermal source. Adiabatic and vertical ionization energies of the ground and first four excited states of α-pyranose, the structure that dominates in the gas phase, were calculated using high-level electronic structure methods. An appearance energy of 9.1(±0.05) eV was recorded, which agrees reasonably well with a theoretical value of 8.8 eV for the adiabatic ionization energy. A clear picture of the dissociative photoionization dynamics of deoxyribose emerges from the fragmentation pattern recorded using mass spectrometry and from ab initio molecular dynamics calculations. The experimental threshold 9.4 (±0.05) eV for neutral water elimination upon ionization is captured well in the calculations, and qualitative insights are provided by molecular orbital analysis and molecular dynamics snapshots along the reaction coordinate.

  13. Superior flexibility of a wrinkled carbon shell under electrochemical cycling

    KAUST Repository

    Li, Qianqian

    2014-01-01

    Nanocarbon composites have been extensively employed in engineering alloy-type anodes in order to improve the poor cyclability caused by the enormous volume changes during lithium (Li+) insertion/extraction. The chemical vapor deposited wrinkled carbon shell (WCS) shows high electrical conductivity, excellent thermal stability and remarkable mechanical robustness, which help in retaining the structural integrity around the tin (Sn) anode core despite ∼250% variation in volume during repetitive lithiation and delithiation. In situ transmission electron microscopy reveals no embrittlement in the lithiated WCS, which fully recovers its original shape after severe mechanical deformation with no obvious structural change. Further analysis indicates that the capacity to accommodate large strains is closely related to the construction of the carbon shell, that is, the stacking of wrinkled few-layer graphenes. Both the pre-existing wrinkles and the few-layer thickness render the carbon shell superior flexibility and good elasticity under bending or expansion of the interior volume. Moreover, the WCS possesses fast lithium ion diffusion channels, which have lower activation barriers (∼0.1 eV) than that on a smooth graphene (∼0.3 eV). The results provide an insight into the improvement in cycle performance that can be achieved through carbon coating of anodes of lithium ion batteries. © 2014 The Royal Society of Chemistry.

  14. Superior calcium homeostasis of extraocular muscles.

    Science.gov (United States)

    Zeiger, Ulrike; Mitchell, Claire H; Khurana, Tejvir S

    2010-11-01

    Extraocular muscles (EOMs) are a unique group of skeletal muscles with unusual physiological properties such as being able to undergo rapid twitch contractions over extended periods and escape damage in the presence of excess intracellular calcium (Ca(2+)) in Duchenne's muscular dystrophy (DMD). Enhanced Ca(2+) buffering has been proposed as a contributory mechanism to explain these properties; however, the mechanisms are not well understood. We investigated mechanisms modulating Ca(2+) levels in EOM and tibialis anterior (TA) limb muscles. Using Fura-2 based ratiometric Ca(2+) imaging of primary myotubes we found that EOM myotubes reduced elevated Ca(2+) ˜2-fold faster than TA myotubes, demonstrating more efficient Ca(2+) buffering. Quantitative PCR (qPCR) and western blotting revealed higher expression of key components of the Ca(2+) regulation system in EOM, such as the cardiac/slow isoforms sarcoplasmic Ca(2+)-ATPase 2 (Serca2) and calsequestrin 2 (Casq2). Interestingly EOM expressed monomeric rather than multimeric forms of phospholamban (Pln), which was phosphorylated at threonine 17 (Thr17) but not at the serine 16 (Ser16) residue. EOM Pln remained monomeric and unphosphorylated at Ser16 despite protein kinase A (PKA) treatment, suggesting differential signalling and modulation cascades involving Pln-mediated Ca(2+) regulation in EOM. Increased expression of Ca(2+)/SR mRNA, proteins, differential post-translational modification of Pln and superior Ca(2+) buffering is consistent with the improved ability of EOM to handle elevated intracellular Ca(2+) levels. These characteristics provide mechanistic insight for the potential role of superior Ca(2+) buffering in the unusual physiology of EOM and their sparing in DMD.

  15. The management of superior sulcus tumors

    Energy Technology Data Exchange (ETDEWEB)

    Komaki, Ritsuko; Cox, J.D.; Putnam, J.B. Jr [Texas Univ., Houston, TX (United States). Anderson Cancer Center] (and others)

    2001-09-01

    Superior sulcus tumors are a rare type of lung cancer arising in the apex of the lung above the sulcus and cause specific symptoms and signs depending on the location and whether the tumor extends into the surrounding structures. Because of the closeness of critical structures to the tumor (e.g., the subclavian artery for anterior lesions, the brachial plexus for lesions in the middle location, and the sympathetic stellate ganglion causing Horner's syndrome [Pancoast's tumor], the vertebral bodies, nerve foramen, and spinal cord for posterior lesions), superior sulcus tumors were often considered marginally respectable or unresectable. Therefore, for many years, preoperative radiation therapy was considered routine treatment for those tumors. However, with the evolution in our understanding of these tumors and modern imaging techniques such as computerized tomography (CT) and magnetic resonant imaging (MRI) and surgical techniques, there is now considerable debate about the roles and timing of surgical resection, radiation therapy, and chemotherapy in the treatment of patients with these tumors. If mediastinoscopy reveals microscopic mediastinal lymph node involvement, the patient can be treated with preoperative concurrent chemoradiotherapy followed by surgery. If there was a gross mediastinal lymph node involvement (N2) on CT, N3 or T4 lesions, the patient can be treated with concurrent chemoradiotherapy with a curative intent; the outcome of such treatment appears to be better than that of sequential chemotherapy followed by radiation therapy. Whenever possible, without compromising the patient's quality of life, surgery should be considered to improve outcome. (author)

  16. Electron impact ionization of large krypton clusters

    Institute of Scientific and Technical Information of China (English)

    Li Shao-Hui; Li Ru-Xin; Ni Guo-Quan; Xu Zhi-Zhan

    2004-01-01

    We show that the detection of ionization of very large van der Waals clusters in a pulsed jet or a beam can be realized by using a fast ion gauge. Rapid positive feedback electron impact ionization and fragmentation processes,which are initially ignited by electron impact ionization of the krypton clusters with the electron current of the ion gauge, result in the appearance of a progressional oscillation-like ion spectrum, or just of a single fast event under critical conditions. Each line in the spectrum represents a correlated explosion or avalanche ionization of the clusters.The phenomena have been analysed qualitatively along with a Rayleigh scattering experiment of the corresponding cluster jet.

  17. Infrared laser desorption/ionization on silicon.

    Science.gov (United States)

    Bhattacharya, Sucharita H; Raiford, Timothy J; Murray, Kermit K

    2002-05-01

    Laser desorption/ionization from a single-crystal silicon surface was performed using a laser operating in the 3-microm region of the mid-infrared. Analyte molecules up to 6 kDa were ionized with no added matrix. As with ultraviolet desorption/ionization from porous silicon (DIOS), IR laser desorption from silicon does not produce matrix ions that can interfere with analysis of low-mass analytes. However, in contrast to UV DIOS, silicon porosity or roughness is not required for ionization using an IR laser. Mass spectra were obtained in the wavelength range between 2.8 and 3.5 microm, which is consistent with energy absorption by a hydrogen-bonded OH group. A mechanism based on desorption of adsorbed solvent molecules is postulated.

  18. Classification of the LHC BLM Ionization Chamber

    CERN Document Server

    Stockner, M; Fabjan, Christian Wolfgang; Holzer, E B; Kramer, Daniel

    2008-01-01

    The LHC beam loss monitoring (BLM) system must prevent the super conducting magnets from quenching and protect the machine components from damage. The main monitor type is an ionization chamber. About 4000 of them will be installed around the ring. The lost beam particles initiate hadronic showers through the magnets and other machine components. These shower particles are measured by the monitors installed on the outside of the accelerator equipment. For the calibration of the BLM system the signal response of the ionization chamber is simulated in GEANT4 for all relevant particle types and energies (keV to TeV range). For validation, the simulations are compared to measurements using protons, neutrons, photons and mixed radiation fields at various energies and intensities. This paper will focus on the signal response of the ionization chamber to various particle types and energies including space charge effects at high ionization densities.

  19. High-Temperature Ionization in Protoplanetary Disks

    CERN Document Server

    Desch, Steven J

    2015-01-01

    We calculate the abundances of electrons and ions in the hot (> 500 K), dusty parts of protoplanetary disks, treating for the first time the effects of thermionic and ion emission from the dust grains. High-temperature ionization modeling has involved simply assuming that alkali elements such as potassium occur as gas-phase atoms and are collisionally ionized following the Saha equation. We show that the Saha equation often does not hold, because free charges are produced by thermionic and ion emission and destroyed when they stick to grain surfaces. This means the ionization state depends not on the first ionization potential of the alkali atoms, but rather on the grains' work functions. The charged species' abundances typically rise abruptly above about 800 K, with little qualitative dependence on the work function, gas density, or dust-to-gas mass ratio. Applying our results, we find that protoplanetary disks' dead zone, where high diffusivities stifle magnetorotational turbulence, has its inner edge locat...

  20. F--Ray: A new algorithm for efficient transport of ionizing radiation

    Science.gov (United States)

    Mao, Yi; Zhang, J.; Wandelt, B. D.; Shapiro, P. R.; Iliev, I. T.

    2014-04-01

    We present a new algorithm for the 3D transport of ionizing radiation, called F2-Ray (Fast Fourier Ray-tracing method). The transfer of ionizing radiation with long mean free path in diffuse intergalactic gas poses a special challenge to standard numerical methods which transport the radiation in position space. Standard methods usually trace each individual ray until it is fully absorbed by the intervening gas. If the mean free path is long, the computational cost and memory load are likely to be prohibitive. We have developed an algorithm that overcomes these limitations and is, therefore, significantly more efficient. The method calculates the transfer of radiation collectively, using the Fast Fourier Transform to convert radiation between position and Fourier spaces, so the computational cost will not increase with the number of ionizing sources. The method also automatically combines parallel rays with the same frequency at the same grid cell, thereby minimizing the memory requirement. The method is explicitly photon-conserving, i.e. the depletion of ionizing photons is guaranteed to equal the photoionizations they caused, and explicitly obeys the periodic boundary condition, i.e. the escape of ionizing photons from one side of a simulation volume is guaranteed to be compensated by emitting the same amount of photons into the volume through the opposite side. Together, these features make it possible to numerically simulate the transfer of ionizing photons more efficiently than previous methods. Since ionizing radiation such as the X-ray is responsible for heating the intergalactic gas when first stars and quasars form at high redshifts, our method can be applied to simulate thermal distribution, in addition to cosmic reionization, in three-dimensional inhomogeneous cosmological density field.

  1. Ionization and fragmentation of cold clusters of PAH molecules - collisions with keV ions

    Science.gov (United States)

    Holm, A. I. S.; Zettergren, H.; Gatchell, M.; Johansson, H. A. B.; Seitz, F.; Schmidt, H. T.; Rousseau, P.; Ławicki, A.; Capron, M.; Domaracka, A.; Lattouf, E.; Maclot, S.; Maisonny, R.; Chesnel, J.-Y.; Manil, B.; Adoui, L.; Huber, B. A.; Cederquist, H.

    2012-11-01

    We discuss the ionization and fragmentation of isolated monomers and cold clusters of polycyclic aromatic hydrocarbon (PAH) molecules in collisions with keV ions in low or high charge states. With low charge state projectile ions, PAH cluster or monomer targets are thermally excited through electronic stopping processes directly in close peripheral or penetrating collisions while only single or few electrons are removed. With high charge state projectiles, electrons are very effectively removed from both the cluster and the monomer target already at very large distances with very little direct target heating. Singly charged and internally very hot PAH monomers are dominant fragmentation products following collisions between Xe20+ ions and PAH clusters. We suggest that this due to an unusually strong dominance of multiple-ionization over single ionization for PAH clusters interacting with highly charged ions. Here, charge and excitation energy is very rapidly redistributed within the clusters before they Coulomb explode and we suggest that these Coulomb explosions induce strong internal heating in the individual PAH molecules. We thus conclude that PAH cluster fragmentation always dominates strongly for all ionization processes regardless if these are due to interactions with ions in high or low charge states. These findings are discussed in view of simple models for cluster evaporation or single and multiple ionizations of PAH clusters.

  2. Two-photon ionization of colliding atoms

    Energy Technology Data Exchange (ETDEWEB)

    Nayfeh, M.H.

    1977-09-01

    Semiclassical expressions of two-photon ionization of two colliding atoms are derived for a wide range of electromagnetic field intensity and detunings from the isolated atom line. The dependence of the ionization yield on the details of the interaction potential of the system is derived. This process promises an extremely sensitive method for studying line broadening on the far wing, especially when absorption or fluorescence becomes very weak.

  3. Positron-impact ionization of Na

    Energy Technology Data Exchange (ETDEWEB)

    Mukherjee, K.K. (Jawahar Navodaya Vidyalaya, Ramchandraghat, West Tripura 799207, Tripura (India)); Singh, N.R. (Thambal Marik College, Oinam, Bishanpur, Manipur (India)); Choudhury, K.B. (Department of Physics, Jadavpur University, Calcutta 700032, West Bengal (India)); Mazumdar, P.S. (Department of Physics, Manipur University, Canchipur, Imphal 795003, Manipur (India))

    1992-07-01

    In this paper we present the total cross sections for the positron-impact ionization of Na in the range 8--30 eV of the energy of the incident positron. Calculations are done by using a distorted-wave approximation incorporating the effects of screening and distortion. The present results are compared with the experimental results for the electron-impact ionization of Na.

  4. The warm ionized medium in spiral galaxies

    CERN Document Server

    Haffner, L M; Beckman, J E; Wood, K; Slavin, J D; Giammanco, C; Madsen, G J; Zurita, A; Reynolds, R J

    2009-01-01

    This article reviews observations and models of the diffuse ionized gas that permeates the disk and halo of our Galaxy and others. It was inspired by a series of invited talks presented during an afternoon scientific session of the 65th birthday celebration for Professor Carl Heiles held at Arecibo Observatory in August 2004. This review is in recognition of Carl's long standing interest in and advocacy for studies of the ionized as well as the neutral components of the interstellar medium.

  5. Drift waves in a weakly ionized plasma

    DEFF Research Database (Denmark)

    Popovic, M.; Melchior, H.

    1968-01-01

    A dispersion relation for low frequency drift waves in a weakly ionized plasma has been derived, and through numerical calculations the effect of collisions between the charged and the neutral particles is estimated.......A dispersion relation for low frequency drift waves in a weakly ionized plasma has been derived, and through numerical calculations the effect of collisions between the charged and the neutral particles is estimated....

  6. Tunneling ionization of vibrationally excited nitrogen molecules

    Science.gov (United States)

    Kornev, Aleksei S.; Zon, Boris A.

    2015-09-01

    Ionization of molecular nitrogen plays an important role in the process of light-filament formation in air. In the present paper we theoretically investigated tunneling ionization of the valence 3 σg and 1 πu shells in a N2 molecule using a strong near-infrared laser field. This research is based on our previously proposed theory of anti-Stokes-enhanced tunneling ionization with quantum accounting for the vibrationally excited states of the molecules [A. S. Kornev and B. A. Zon, Phys. Rev. A 86, 043401 (2012), 10.1103/PhysRevA.86.043401]. We demonstrated that if the N2 molecule is ionized from the ground vibrational state, then the contribution of the 1 πu orbital is 0.5%. In contrast, for vibrationally excited states with a certain angle between the light polarization vector and the molecule axis, both shells can compete and even reverse their contributions due to the anti-Stokes mechanism. The structure constants of molecular orbitals are extracted from numerical solutions to the Hartree-Fock equations. This approach correctly takes into account the exchange interaction. Quantum consideration of vibrational motion results in the occurrence of the critical vibrational state, the tunneling ionization from which has the maximum rate. The numbers of the critical vibrational states are different for different valence shells. In addition, quantum description of vibrations changes the rate of ionization from the ground vibrational state by 20%-40% in comparison with the quasiclassical results.

  7. Multiple ionization of argon by helium ions

    Science.gov (United States)

    Montanari, C. C.; Miraglia, J. E.

    2016-09-01

    We apply the continuum distorted-wave eikonal initial state and the independent electron model to describe the multiple ionization of Ar by He2+ and He+ in the energy range 0.1-10 Mev amu-1. Auger-like post collisional processes are included, which enhance the high energy multiple ionization cross sections via ionization of the inner shells. All Ar electrons (K, L and M-shells) have been included in these calculations. The results agree well with the experimental data at high energies, where the post-collisional ionization is the main contribution. At intermediate impact energies the description is also good though it tends to overestimate the triple and quadruple ionization data at intermediate energies. We analyze this by comparing the present results for He+2 in Ar, with previous ones for He+2 in Ne and Kr. It was found that the theoretical description improves from Ne to Ar and Kr, with the latter being nicely described even at intermediate energies. The present formalism is also tested for Ar inner shell and total ionization cross sections. In all the cases the results above 0.1 MeV amu-1 are quite reasonable, as compared with the experimental data available and with the ECPSSR values.

  8. Commercial applications of food ionization in France

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Pierre-Louis [Ionisos S.A. (France)

    1994-12-31

    Due to the long history of nuclear energy in France, French public is not frightened by nuclear applications in its everyday life. The first industrial initiative on food ionization dates back to 1956. In 1980, the Joint Expert Committee on Food Ionization concluded that food ionization up to a certain maximum dose presented neither toxicological nor nutritional hazard. This opened the new era for the industrial development. But in 1988, a draft directive to harmonize national legislations was issued by the Commission of European Communities. This stopped many industrial initiatives due to uncertainty. It is estimated that nearly 14,000 tons of various food items have been ionized in France in 1991. About 40% are spices, followed by dry fruit, vegetables, and deboned poultry meat. Most of the present applications are intended to eliminate microorganisms. In 1992, 8 industrial facilities were in operation, mostly using gamma sources. Local research associations were founded to promote food ionization. Food ionization development in the past 30 years has been rapid and important, but the future of this process depends on the European harmonization of legislations. (K.I.).

  9. Intermediate- and High-Velocity Ionized Gas toward zeta Orionis

    CERN Document Server

    Welty, D E; Raymond, J C; Mallouris, C; York, D G

    2002-01-01

    We combine UV spectra obtained with the HST/GHRS echelle, IMAPS, and Copernicus to study the abundances and physical conditions in the predominantly ionized gas seen at high (-105 to -65 km/s) and intermediate velocities (-60 to -10 km/s) toward zeta Ori. We have high resolution (FWHM ~ 3.3-4.5 km/s) and/or high S/N spectra for at least two significant ions of C, N, Al, Si, S, and Fe -- enabling accurate estimates for both the total N(H II) and the elemental depletions. C, N, and S have essentially solar relative abundances; Al, Si, and Fe appear to be depleted by about 0.8, 0.3-0.4, and 0.95 dex, respectively. While various ion ratios would be consistent with collisional ionization equilibrium (CIE) for T ~ 25,000-80,000 K, the widths of individual high-velocity absorption components indicate that T ~ 9000 K -- so the gas is not in CIE. Analysis of the C II fine-structure excitation equilibrium yields estimated densities (n_e ~ n_H ~ 0.1-0.2 cm^{-3}), thermal pressures (2 n_H T ~ 2000-4000 cm^{-3}K), and thi...

  10. Secondary ionization mass spectrometry analysis in petrochronology: Chapter 7

    Science.gov (United States)

    Schmitt, Axel K.; Vazquez, Jorge A.

    2017-01-01

    The goal of petrochronology is to extract information about the rates and conditions at which rocks and magmas are transported through the Earth’s crust. Garnering this information from the rock record greatly benefits from integrating textural and compositional data with radiometric dating of accessory minerals. Length scales of crystal growth and diffusive transport in accessory minerals under realistic geologic conditions are typically in the range of 1–10’s of μm, and in some cases even substantially smaller, with zircon having among the lowest diffusion coefficients at a given temperature (e.g., Cherniak and Watson 2003). Intrinsic to the compartmentalization of geochemical and geochronologic information from intra-crystal domains is the requirement to determine accessory mineral compositions using techniques that sample at commensurate spatial scales so as to not convolute the geologic signals that are recorded within crystals, as may be the case with single grain or large grain fragment analysis by isotope dilution thermal ionization mass spectrometry (ID-TIMS; e.g., Schaltegger and Davies 2017, this volume; Schoene and Baxter 2017, this volume). Small crystals can also be difficult to extract by mineral separation techniques traditionally used in geochronology, which also lead to a loss of petrographic context. Secondary Ionization Mass Spectrometry, that is SIMS performed with an ion microprobe, is an analytical technique ideally suited to meet the high spatial resolution analysis requirements that are critical for petrochronology (Table 1).

  11. Turbulence in the Ionized Gas of the Orion Nebula

    CERN Document Server

    Arthur, S J; Henney, W J

    2016-01-01

    In order to study the nature, origin, and impact of turbulent velocity fluctuations in the ionized gas of the Orion Nebula, we apply a variety of statistical techniques to observed velocity cubes. The cubes are derived from high resolving power ($R \\approx 40,000$) longslit spectroscopy of optical emission lines that span a range of ionizations. From Velocity Channel Analysis (VCA), we find that the slope of the velocity power spectrum is consistent with predictions of Kolmogorov theory between scales of 8 and 22 arcsec (0.02 to 0.05 pc). The outer scale, which is the dominant scale of density fluctuations in the nebula, approximately coincides with the autocorrelation length of the velocity fluctuations that we determine from the second order velocity structure function. We propose that this is the principal driving scale of the turbulence, which originates in the autocorrelation length of dense cores in the Orion molecular filament. By combining analysis of the non-thermal line widths with the systematic tr...

  12. Mobility and impact ionization in silicon at high temperature

    Energy Technology Data Exchange (ETDEWEB)

    Corvasce, C.

    2007-07-01

    In the field of the high-temperature modelling and simulation of semiconductor devices, most of the physical models available to date have been validated only to 400 K, in spite of the fact that the local heating during the stress event can lead to local temperatures well in excess of this limit. This work deals with the mobility and the impact ionization in silicon at high temperature. The mobility has been measured by the Hall technique up to 1000 K thanks to the use of dedicated Ti/TiN interconnections in combination with junction-free van der Pauw resistors, which are intrinsically immune of spurious thermal leakage currents. The hole and the electron impact ionization coefficients have been determined as a function of the electric field up to 673 K and 613 K, respectively, by measurements of the multiplication factor in bipolar and static induction transistors. The results collected in this work represent an extensive reference data set, which is suitable for the calibration of compact models for numerical simulation. (orig.)

  13. An Experimental Study of Nonstationary Instabilities of Planar Shock Waves in Ionizing Argon

    Science.gov (United States)

    1980-08-01

    amplification of acoustic disturbances in an electrically -heated two-temperature (Te >> Ta) plasma. Since 4the thermally-heated ionizing argon plasma...the schlieren system. In the present study it was felt that any sensitibity ’ 3st by using a diffused slit-source instead of an undiff’used point...parameters such as XE, it can help stimulate discussion on the instability phenomenon. Experimental and analytical research into acoustic stability

  14. The influence of variations of elemental composition on the thermal properties of interstellar gas

    Science.gov (United States)

    Vasiliev, E. O.; Shchekinov, Yu. A.

    2016-10-01

    The mixing of metals and redistribution of the relative abundances of chemical elements in the interstellar medium often takes place on a timescale that exceeds the characteristic timescales for many other processes, such as ionization and the establishment of thermal equilibrium. Under these conditions, different regions of interstellar gas can have different thermal, chemical, and spectral properties. The paper considers the ionization kinetics and thermal regime of interstellar gas with variations in the relative elemental abundances. The thermal properties and observational (spectral) characteristics are most sensitive to variations of the relative abundance of carbon, oxygen, neon, and iron. The dynamic consequences of such variations are considered.

  15. Helium Ionization in the Diffuse Ionized Gas Surrounding UCH ii Regions

    Science.gov (United States)

    Anish Roshi, D.; Churchwell, E.; Anderson, L. D.

    2017-04-01

    We present measurements of the singly ionized helium-to-hydrogen ratio ({n}{{He}+}/{n}{{{H}}+}) toward diffuse gas surrounding three ultracompact H ii (UCH ii) regions: G10.15-0.34, G23.46-0.20, and G29.96-0.02. We observe radio recombination lines of hydrogen and helium near 5 GHz using the GBT to measure the {n}{{He}+}/{n}{{{H}}+} ratio. The measurements are motivated by the low helium ionization observed in the warm ionized medium and in the inner Galaxy diffuse ionized regions. Our data indicate that the helium is not uniformly ionized in the three observed sources. Helium lines are not detected toward a few observed positions in sources G10.15-0.34 and G23.46-0.20, and the upper limits of the {n}{{He}+}/{n}{{{H}}+} ratio obtained are 0.03 and 0.05, respectively. The selected sources harbor stars of type O6 or hotter as indicated by helium line detection toward the bright radio continuum emission from the sources with mean {n}{{He}+}/{n}{{{H}}+} value 0.06 ± 0.02. Our data thus show that helium in diffuse gas located a few parsecs away from the young massive stars embedded in the observed regions is not fully ionized. We investigate the origin of the nonuniform helium ionization and rule out the possibilities (a) that the helium is doubly ionized in the observed regions and (b) that the low {n}{{He}+}/{n}{{{H}}+} values are due to additional hydrogen ionizing radiation produced by accreting low-mass stars. We find that selective absorption of ionizing photons by dust can result in low helium ionization but needs further investigation to develop a self-consistent model for dust in H ii regions.

  16. Ametryne degradation by ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Debora Cristina de; Mori, Manoel Nunes; Duarte, Celina Lopes [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mails: deboracandrade@globo.com; mnmori@ipen.br; clduarte@ipen.br; Melo, Rita Paiva [Technological and Nuclear Institute (ITN), Sacavem (Portugal)]. E-mail: ritamelo@itn.pt

    2007-07-01

    Ametryne may be released to the environment during its manufacture, transport, storage, formulation and use as selective herbicide for the control of annual broadleaf and grass weeds. It is applied as an aqueous suspension for preemergence or post-directed applications on crops. Depending on the pesticide formulation and type of application, ametryne residues may be detectable in water, soil and on the surfaces for months or years. The herbicide used to this study was Ametryne (commercial name, Gesapax 500), commonly used on field crops and on corn and commercialized since 1975. Ametryne was analyzed by gas chromatography (GC Shimadzu 17A), after extraction with hexane/dichloromethane (1:1 v/v) solution. The calibration curve was obtained with a regression coefficient of 0.9871. In addition, the relative standard deviation was lower than 10%. The radiation-processing yield was evaluated by the destruction G-value (Gd) (Eq. 1), that is defined by the number of destroyed molecules by absorption of 100 eV of energy from ionizing radiation. Different concentrations of the herbicide (11.4 mol L{sup -1}; 22.7 mol L{sup -1}; 34.1 mol L{sup -1} and 45.5 mol L{sup -1}) were irradiated at the AECL 'Gammacell 220' {sup 60}Co source, with 1 kGy, 3 kGy, 6 kGy, 9 kGy, 12 kGy, 15 kGy and 30 kGy absorbed doses. After irradiation processing, the ametryne highest reduction rate occurs at low doses of radiation: at 6 kGy more than 85-90% of all ametryne compounds were removed. Two products of incomplete degradation of ametryne were identified as s-triazyne isomers. However, further work is needed in order to fully understand the ametryne degradation mechanisms the degradation yield of ametryne depends on its initial concentration and the process seems to be more efficient at higher concentrations. (author)

  17. Food preservation using ionizing radiation.

    Science.gov (United States)

    Andrews, L S; Ahmedna, M; Grodner, R M; Liuzzo, J A; Murano, P S; Murano, E A; Rao, R M; Shane, S; Wilson, P W

    1998-01-01

    Irradiation processing has been researched extensively and is now in use worldwide for many food commodities. Irradiation has been successfully used to reduce pathogenic bacteria, eliminate parasites, decrease postharvest sprouting, and extend the shelf life of fresh perishable foods. Although food irradiation is widely accepted in world food markets, U.S. markets have been slower to accept the idea of irradiated food products. For fruits and vegetables, irradiation is not a cure for shelf life problems; cost and quality problems damage preclude its general use. It appears that the most likely use of irradiation in fruits and vegetables is as an insect control in those commodities for which there is no effective alternative method. For grains such as rice and wheat, irradiation has been used primarily to control insect infestation when insects have been shown to develop resistance to the traditional fumigation methods. Treatment of spices with irradiation doses of 10 kGy has proved to extend shelf life without causing significant changes in sensory or chemical quality. Higher doses that effectively sterilize spices, however, may cause undesirable chemical and sensorial changes. For meat, especially red meat, irradiation is considered a viable alternative in the effort to improve the safety of meat products. With time, the authors believe that economic realities and the technical superiority of irradiation for specific poultry products will lead to public acceptance of the process. Irradiation of seafood products is still being considered for approval by the USFDA, although it is currently used in Asian and European markets, especially for shrimp. It is our belief that scientifically based research in food irradiation and the positive results thereof will also prove economical in the twenty-first century. As we move to a more peaceful world with reduced threat of nuclear holocaust, these valid opinions will prevail and will overshadow the distortions and

  18. Photo-ionization rate coefficients for the rare gases

    Science.gov (United States)

    Pang, Xuexia

    2005-01-01

    By introducing the converting method from electron-impact ionization cross sections to rate coefficients through using a semi-experiential formula, we try to probe a semi-experiential formula for converting the photo-ionization cross sections into photo-ionization rate coefficient. It"s found that photo-ionization rate coefficient is direct proportion to photo-ionization cross sections, the rate S is related with light resource.

  19. Lake Superior Coastal Wetland Fish Assemblages and ...

    Science.gov (United States)

    The role of the coastal margin and the watershed context in defining the ecology of even very large lakes is increasingly being recognized and examined. Coastal wetlands are both important contributors to the biodiversity and productivity of large lakes and important mediators of the lake-basin connection. We explored wetland-watershed connections and their relationship to wetland function and condition using data collected from 37 Lake Superior wetlands spanning a substantial geographic and geomorphic gradient. While none of these wetlands are particularly disturbed, there were nevertheless clear relationships between watershed landuse and wetland habitat and biota, and these varied consistently across wetland type categories that reflected the strength of connection to the watershed. For example, water clarity and vegetation structure complexity declined with decreasing percent natural land cover, and these effects were strongest in riverine wetlands (having generally large watersheds and tributary-dominated hydrology) and weakest in lagoon wetlands (having generally small watersheds and lake-dominate hydrology). Fish abundance and species richness both increased with decreasing percent natural land cover while species diversity decreased, and again the effect was strongest in riverine wetlands. Lagoonal wetlands, which lack any substantial tributary, consistently harbored the fewest species of fish and a composition different from the more watershed-lin

  20. Degradation Characterization of Thermal Interface Greases: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    DeVoto, Douglas J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Major, Joshua [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Paret, Paul P [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-08-03

    Thermal interface materials (TIMs) are used in power electronics packaging to minimize thermal resistance between the heat generating component and the heat sink. Thermal greases are one such class. The conformability and thin bond line thickness (BLT) of these TIMs can potentially provide low thermal resistance throughout the operation lifetime of a component. However, their performance degrades over time due to pump-out and dry-out during thermal and power cycling. The reliability performance of greases through operational cycling needs to be quantified to develop new materials with superior properties. NREL, in collaboration with DuPont, has performed thermal and reliability characterization of several commercially available thermal greases. Initial bulk and contact thermal resistance of grease samples were measured, and then the thermal degradation that occurred due to pump-out and dry-out during temperature cycling was monitored. The thermal resistances of five different grease materials were evaluated using NREL's steady-state thermal resistance tester based on the ASTM test method D5470. Greases were then applied, utilizing a 2.5 cm x 2.5 cm stencil, between invar and aluminum plates to compare the thermomechanical performance of the materials in a representative test fixture. Scanning Acoustic microscopy, thermal, and compositional analyses were performed periodically during thermal cycling from -40 degrees Celcius to 125 degrees Celcius. Completion of this characterization has allowed for a comprehensive evaluation of thermal greases both for their initial bulk and contact thermal performance, as well as their degradation mechanisms under accelerated thermal cycling conditions.

  1. Multiphoton ionization of large water clusters.

    Science.gov (United States)

    Apicella, B; Li, X; Passaro, M; Spinelli, N; Wang, X

    2014-05-28

    Water clusters are multimers of water molecules held together by hydrogen bonds. In the present work, multiphoton ionization in the UV range coupled with time of flight mass spectrometry has been applied to water clusters with up to 160 molecules in order to obtain information on the electronic states of clusters of different sizes up to dimensions that can approximate the bulk phase. The dependence of ion intensities of water clusters and their metastable fragments produced by laser ionization at 355 nm on laser power density indicates a (3+1)-photon resonance-enhanced multiphoton ionization process. It also explains the large increase of ionization efficiency at 355 nm compared to that at 266 nm. Indeed, it was found, by applying both nanosecond and picosecond laser ionization with the two different UV wavelengths, that no water cluster sequences after n = 9 could be observed at 266 nm, whereas water clusters up to m/z 2000 Th in reflectron mode and m/z 3000 Th in linear mode were detected at 355 nm. The agreement between our findings on clusters of water, especially true in the range with n > 10, and reported data for liquid water supports the hypothesis that clusters above a critical dimension can approximate the liquid phase. It should thus be possible to study clusters just above 10 water molecules, for getting information on the bulk phase structure.

  2. LET measurements with a liquid ionization chamber

    Energy Technology Data Exchange (ETDEWEB)

    Tegami, Sara

    2013-02-08

    Deep-seated tumors can be efficiently treated with heavy charged particles. The characteristic depth dose profile inside the tissue (Bragg peak) allows to deliver a high dose inside the tumor, while sparing the neighboring healthy tissue. As compared to protons, heavy ions like carbon or oxygen produce a higher amount of ionization events along their track (and in particular at the end of the ion beam path), resulting in an irreparable damage to the DNA of the tumor cells. The density of such ionization events is described in terms of Linear Energy Transfer (LET), an important physical quantity, but difficult to be measured directly. The aim of this work is to determine LET of hadrontherapy beams by using Liquid Ionization Chambers (LIC). The ionization signal in LICs is affected by recombination effects that depend on the LET of the incident radiation. Differences in recombination effects in LICs and air-filled ionization chambers can be exploited to obtain the recombination index, which can be related to the LET, calculated by Monte Carlo methods. We thus developed a method to construct a calibration curve, which relates the recombination index with the LET at each depth in water. The result of this work can be used for online monitoring of the ion beam quality.

  3. Laboratory simulation of cometary neutral gas ionization

    Science.gov (United States)

    Chang, Tsuey-Fen; Rahman, H. U.; White, R. S.

    1989-01-01

    The laboratory simulation of the interaction of the solar wind with a comet is used to study the cometary neural gas ionization. The experiment is carried out in the UCR T-1 facility with an ice ball as the comet model. Photographs and data are taken with a variety of values of the solar wind velocity, interplanetary magnetic field (IMF), and comet configurations. The results show that the cometary neutral gas ionization depends on both the velocity of the solar wind and the interplanetary magnetic field. The plasma cloud surrounding the comet is visible only when the solar wind velocity and IMF are both above certain minimum values. This velocity dependent phenomena is explained by Alfven's critical ionization velocity effect. The critical magnetic field may be explained by assuming two stream lower hybrid instability as a triggering mechanism for the ionization of the neutral gas by plasma flow. Critical upper and lower limits for the magnetic field, required by anomalous ionization, are also derived that satisfy the experimental observations.

  4. Ionizing radiation and genetic risks

    Energy Technology Data Exchange (ETDEWEB)

    Sankaranarayanan, K. [Department of Toxicogenetics, Leiden University Medical Centre, Sylvius Laboratories, Wassenaarseweg 72, 2333 AL Leiden (Netherlands)]. E-mail: sankaran@lumc.nl; Wassom, J.S. [YAHSGS, LLC, Richland, WA 99352 (United States); Life Sciences Division, Oak Ridge National Laboratory, Oak Ridge, TN 37830 (United States)

    2005-10-15

    Recent estimates of genetic risks from exposure of human populations to ionizing radiation are those presented in the 2001 report of the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR). These estimates incorporate two important concepts, namely, the following: (1) most radiation-induced mutations are DNA deletions, often encompassing multiple genes, but only a small proportion of the induced deletions is compatible with offspring viability; and (2) the viability-compatible deletions induced in germ cells are more likely to manifest themselves as multi-system developmental anomalies rather than as single gene disorders. This paper: (a) pursues these concepts further in the light of knowledge of mechanisms of origin of deletions and other rearrangements from two fields of contemporary research: repair of radiation-induced DNA double-strand breaks (DSBs) in mammalian somatic cells and human molecular genetics; and (b) extends them to deletions induced in the germ cell stages of importance for radiation risk estimation, namely, stem cell spermatogonia in males and oocytes in females. DSB repair studies in somatic cells have elucidated the roles of two mechanistically distinct pathways, namely, homologous recombination repair (HRR) that utilizes extensive sequence homology and non-homologous end-joining (NHEJ) that requires little or no homology at the junctions. A third process, single-strand annealing (SSA), which utilizes short direct repeat sequences, is considered a variant of HRR. HRR is most efficient in late S and G{sub 2} phases of the cell cycle and is a high fidelity mechanism. NHEJ operates in all cell cycle phases, but is especially important in G{sub 1}. In the context of radiation-induced DSBs, NHEJ is error-prone. SSA is also an error-prone mechanism and its role is presumably similar to that of HRR. Studies in human molecular genetics have demonstrated that the occurrence of large deletions, duplications or other

  5. Carbon phosphide monolayers with superior carrier mobility

    Science.gov (United States)

    Wang, Gaoxue; Pandey, Ravindra; Karna, Shashi P.

    2016-04-01

    Two dimensional (2D) materials with a finite band gap and high carrier mobility are sought after materials from both fundamental and technological perspectives. In this paper, we present the results based on the particle swarm optimization method and density functional theory which predict three geometrically different phases of the carbon phosphide (CP) monolayer consisting of sp2 hybridized C atoms and sp3 hybridized P atoms in hexagonal networks. Two of the phases, referred to as α-CP and β-CP with puckered or buckled surfaces are semiconducting with highly anisotropic electronic and mechanical properties. More remarkably, they have the lightest electrons and holes among the known 2D semiconductors, yielding superior carrier mobility. The γ-CP has a distorted hexagonal network and exhibits a semi-metallic behavior with Dirac cones. These theoretical findings suggest that the binary CP monolayer is a yet unexplored 2D material holding great promise for applications in high-performance electronics and optoelectronics.Two dimensional (2D) materials with a finite band gap and high carrier mobility are sought after materials from both fundamental and technological perspectives. In this paper, we present the results based on the particle swarm optimization method and density functional theory which predict three geometrically different phases of the carbon phosphide (CP) monolayer consisting of sp2 hybridized C atoms and sp3 hybridized P atoms in hexagonal networks. Two of the phases, referred to as α-CP and β-CP with puckered or buckled surfaces are semiconducting with highly anisotropic electronic and mechanical properties. More remarkably, they have the lightest electrons and holes among the known 2D semiconductors, yielding superior carrier mobility. The γ-CP has a distorted hexagonal network and exhibits a semi-metallic behavior with Dirac cones. These theoretical findings suggest that the binary CP monolayer is a yet unexplored 2D material holding great

  6. Absent right superior caval vein in situs solitus

    DEFF Research Database (Denmark)

    Lytzen, Rebekka; Sundberg, Karin; Vejlstrup, Niels

    2015-01-01

    no postnatal complications. All children were found to have healthy hearts at follow-up. CONCLUSIONS: In all cases, the findings proved to be a benign condition with no clinical manifestations or complications. Although isolated absent right superior caval vein does not seem to affect the outcome, associated......Introduction In up to 0.07% of the general population, the right anterior cardinal vein obliterates and the left remains open, creating an absent right superior caval vein and a persistent left superior caval vein. Absent right superior caval vein is associated with additional congenital heart...... disease in about half the patients. We wished to study the consequences of absent right superior caval vein as an incidental finding on prenatal ultrasonic malformation screening. Material and methods This is a retrospective case series study of all foetuses diagnosed with absent right superior caval vein...

  7. The Business Value of Superior Energy Performance

    Energy Technology Data Exchange (ETDEWEB)

    McKane, Aimee; Scheihing, Paul; Evans, Tracy; Glatt, Sandy; Meffert, William

    2015-08-04

    Industrial facilities participating in the U.S. Department of Energy’s (US DOE) Superior Energy Performance (SEP) program are finding that it provides them with significant business value. This value starts with the implementation of ISO 50001-Energy management system standard, which provides an internationally-relevant framework for integration of energy management into an organization’s business processes. The resulting structure emphasizes effective use of available data and supports continual improvement of energy performance. International relevance is particularly important for companies with a global presence or trading interests, providing them with access to supporting ISO standards and a growing body of certified companies representing the collective knowledge of communities of practice. This paper examines the business value of SEP, a voluntary program that builds on ISO 50001, inviting industry to demonstrate an even greater commitment through third-party verification of energy performance improvement to a specified level of achievement. Information from 28 facilities that have already achieved SEP certification will illustrate key findings concerning both the value and the challenges from SEP/ISO 50001 implementation. These include the facilities’ experience with implementation, internal and external value of third-party verification of energy performance improvement; attractive payback periods and the importance of SEP tools and guidance. US DOE is working to bring the program to scale, including the Enterprise-Wide Accelerator (SEP for multiple facilities in a company), the Ratepayer-Funded Program Accelerator (supporting tools for utilities and program administrators to include SEP in their program offerings), and expansion of the program to other sectors and industry supply chains.

  8. Solar Thermal Concept Evaluation

    Science.gov (United States)

    Hawk, Clark W.; Bonometti, Joseph A.

    1995-01-01

    Concentrated solar thermal energy can be utilized in a variety of high temperature applications for both terrestrial and space environments. In each application, knowledge of the collector and absorber's heat exchange interaction is required. To understand this coupled mechanism, various concentrator types and geometries, as well as, their relationship to the physical absorber mechanics were investigated. To conduct experimental tests various parts of a 5,000 watt, thermal concentrator, facility were made and evaluated. This was in anticipation at a larger NASA facility proposed for construction. Although much of the work centered on solar thermal propulsion for an upper stage (less than one pound thrust range), the information generated and the facility's capabilities are applicable to material processing, power generation and similar uses. The numerical calculations used to design the laboratory mirror and the procedure for evaluating other solar collectors are presented here. The mirror design is based on a hexagonal faceted system, which uses a spherical approximation to the parabolic surface. The work began with a few two dimensional estimates and continued with a full, three dimensional, numerical algorithm written in FORTRAN code. This was compared to a full geometry, ray trace program, BEAM 4, which optimizes the curvatures, based on purely optical considerations. Founded on numerical results, the characteristics of a faceted concentrator were construed. The numerical methodologies themselves were evaluated and categorized. As a result, the three-dimensional FORTRAN code was the method chosen to construct the mirrors, due to its overall accuracy and superior results to the ray trace program. This information is being used to fabricate and subsequently, laser map the actual mirror surfaces. Evaluation of concentrator mirrors, thermal applications and scaling the results of the 10 foot diameter mirror to a much larger concentrator, were studied. Evaluations

  9. Coronary artery bypass and superior vena cava syndrome.

    OpenAIRE

    Thomas, T V; Masrani, K; Thomas, J.L.

    1999-01-01

    Superior vena cava syndrome is the obstruction of the superior vena cava or its main tributaries by benign or malignant lesions. The syndrome causes edema and engorgement of the vessels on the face, neck, and arms, nonproductive cough, and dyspnea. We discuss the case of a 48-year-old obese diabetic woman who was admitted with unstable angina. She had previously been diagnosed with superior vena cava syndrome. Urgent coronary artery bypass grafting was necessary Although thousands of coronary...

  10. Superiorization of incremental optimization algorithms for statistical tomographic image reconstruction

    Science.gov (United States)

    Helou, E. S.; Zibetti, M. V. W.; Miqueles, E. X.

    2017-04-01

    We propose the superiorization of incremental algorithms for tomographic image reconstruction. The resulting methods follow a better path in its way to finding the optimal solution for the maximum likelihood problem in the sense that they are closer to the Pareto optimal curve than the non-superiorized techniques. A new scaled gradient iteration is proposed and three superiorization schemes are evaluated. Theoretical analysis of the methods as well as computational experiments with both synthetic and real data are provided.

  11. 77 FR 48856 - Safety Zone; Superior Bay, Duluth, MN

    Science.gov (United States)

    2012-08-15

    ... spectators during the Superior Man Triathlon. DATES: This rule is effective from 6 a.m. to 8:30 a.m. on... Triathlon, which are discussed further below. Under 5 U.S.C. 553(d)(3), the Coast Guard finds that good... inaugural Superior Man Triathlon will occur along the Bay of Lake Superior. The 1.2 mile swim leg of...

  12. A new type of carbon resistance thermometer with excellent thermal contact at millikelvin temperatures

    CERN Document Server

    Samkharadze, Nodar; Csáthy, Gábor A

    2010-01-01

    Using a new brand of commercially available carbon resistor we built a cryogenic thermometer with an extremely good thermal contact to its thermal environment. Because of its superior thermal contact the thermometer is insensitive to low levels of spurious radio frequency heating. We calibrated our thermometer down to 5mK using a quartz tuning fork He-3 viscometer and measured its thermal resistance and thermal response time.

  13. Nuclear Fission Investigation with Twin Ionization Chamber

    Science.gov (United States)

    Zeynalova, O.; Zeynalov, Sh.; Nazarenko, M.; Hambsch, F.-J.; Oberstedt, S.

    2011-11-01

    The purpose of the present paper was to report the recent results, obtained in development of digital pulse processing mathematics for prompt fission neutron (PFN) investigation using twin ionization chamber (TIC) along with fast neutron time-of-flight detector (ND). Due to well known ambiguities in literature (see refs. [4, 6, 9 and 11]), concerning a pulse induction on TIC electrodes by FF ionization, we first presented detailed mathematical analysis of fission fragment (FF) signal formation on TIC anode. The analysis was done using Ramo-Shockley theorem, which gives relation between charged particle motion between TIC electrodes and so called weighting potential. Weighting potential was calculated by direct numerical solution of Laplace equation (neglecting space charge) for the TIC geometry and ionization, caused by FF. Formulae for grid inefficiency (GI) correction and digital pulse processing algorithms for PFN time-of-flight measurements and pulse shape analysis are presented and discussed.

  14. Ionization of atoms by chirped attosecond pulses

    Institute of Scientific and Technical Information of China (English)

    Tan Fang; Peng Liang-You; Gong Qi-Huang

    2009-01-01

    We investigate the ionization dynamics of atoms by chirped attosecond pulses using the strong field approximation method. The pulse parameters are carefully chosen in the regime where the strong field approximation method is valid. We analyse the effects of the chirp of attosecond pulses on the energy distributions and the corresponding left-right asymmetry of the ionized electrons. For a single chirped attosecond pulse, the ionized electrons can be redistributed and the left-right asymmetry shows oscillations because of the introduction of the chirp. For time-delayed double attosecond pulses at different intensities with the weaker one chirped, exchanging the order of the two pulses shows a relative shift of the energy spectra, which can be explained by the different effective time delays of different frequency components because of the chirp.

  15. Ionization Modeling Astrophysical Gaseous Structures. I. The Optically Thin Regime

    CERN Document Server

    Churchill, Christopher W; Medina, Amber; Vliet, Jacob R Vander

    2014-01-01

    We present a code for modelling the ionization conditions of optically thin astrophysical gas structures. Given the gas hydrogen density, equilibrium temperature, elemental abundances, and the ionizing spectrum, the code solves the equilibrium ionization fractions and number densities for all ions from hydrogen to zinc. The included processes are photoionization, Auger ionization, direct collisional ionization, excitation auto-ionization, charge exchange ionization, two-body radiative recombination, dielectronic recombination, and charge exchange recombination. The ionizing spectrum can be generalized to include the ultraviolet background (UVB) and/or Starburst99 stellar populations of various masses, ages, metallicities, and distances. The ultimate goal with the code is to provide fast computation of the ionization conditions of gas in N-body + hydrodynamics cosmological simulations, in particular adaptive mesh refinement codes, in order to facilitate absorption line analysis of the simulated gas for compari...

  16. Superior Mesenteric Artery Syndrome: An Infrequent Complication of Scoliosis Surgery

    Directory of Open Access Journals (Sweden)

    Metin Keskin

    2014-01-01

    Full Text Available Superior mesenteric artery syndrome is a rare condition that causes a proximal small intestinal obstruction due to contraction of the angle between the superior mesenteric artery and the aorta. Scoliosis surgery is one of the 15 reasons for superior mesenteric artery syndrome, which can present with acute or chronic manifestations. Although conservative treatment is usually possible, surgical treatment is required in certain cases that cannot be treated using conservative methods. In this paper, we describe a patient who developed superior mesenteric artery syndrome after scoliosis surgery and was treated with duodenojejunostomy due to failure and complications of conservative treatment.

  17. Superior Vena Cava Thrombosis in a Case of Lung Adenocarcinoma

    Directory of Open Access Journals (Sweden)

    Santanu Ghosh

    2013-01-01

    Full Text Available Superior vena cava syndrome is a common presentation of bronchogenic carcinoma. The mechanism of obstruction is by compression of superior vena cava by the bronchogenic tumor itself or enlarged mediastinal lymph nodes. However obstruction due to intravascular thrombosis is extremely uncommon. Here, we report a rare case of a 65-year-old male smoker who presented with superior vena cava syndrome and bilateral pleural and pericardial effusion with thrombotic occlusion of the superior vena cava in adenocarcinoma of the lung. He was given chemotherapy with carboplatin and gemcitabine with anticoagulant therapy.

  18. Atmospheric pressure ionization-tandem mass spectrometry of the phenicol drug family.

    Science.gov (United States)

    Alechaga, Élida; Moyano, Encarnación; Galceran, M Teresa

    2013-11-01

    In this work, the mass spectrometry behaviour of the veterinary drug family of phenicols, including chloramphenicol (CAP) and its related compounds thiamphenicol (TAP), florfenicol (FF) and FF amine (FFA), was studied. Several atmospheric pressure ionization sources, electrospray (ESI), atmospheric pressure chemical ionization and atmospheric pressure photoionization were compared. In all atmospheric pressure ionization sources, CAP, TAP and FF were ionized in both positive and negative modes; while for the metabolite FFA, only positive ionization was possible. In general, in positive mode, [M + H](+) dominated the mass spectrum for FFA, while the other compounds, CAP, TAP and FF, with lower proton affinity showed intense adducts with species present in the mobile phase. In negative mode, ESI and atmospheric pressure photoionization showed the deprotonated molecule [M-H](-), while atmospheric pressure chemical ionization provided the radical molecular ion by electron capture. All these ions were characterized by tandem mass spectrometry using the combined information obtained by multistage mass spectrometry and high-resolution mass spectrometry in a quadrupole-Orbitrap instrument. In general, the fragmentation occurred via cyclization and losses or fragmentation of the N-(alkyl)acetamide group, and common fragmentation pathways were established for this family of compounds. A new chemical structure for the product ion at m/z 257 for CAP, on the basis of the MS(3) and MS(4) spectra is proposed. Thermally assisted ESI and selected reaction monitoring are proposed for the determination of these compounds by ultra high-performance liquid chromatography coupled to tandem mass spectrometry, achieving instrumental detection limits down to 0.1 pg. Copyright © 2013 John Wiley & Sons, Ltd.

  19. Cold-spray ionization mass spectrometry: applications in structural coordination chemistry.

    Science.gov (United States)

    Yamaguchi, Kentaro

    2013-01-01

    Electrospray ionization (ESI)-mass spectrometry (MS) is generally used for the characterization of labile supramolecules in which non-covalent bonding interactions are predominant. However, molecular ions are not detected in many cases because of their instability, and even if such ions are detected, thermal decomposition generates fragment ions that also appear in the mass spectrum. Cold-spray ionization (CSI) is designed for the MS detection of labile organic species. It is used to analyze the structures of biomolecular complexes and labile organic species in solution. The method, a variant of ESI-MS, operates at low temperature, allowing simple and precise characterization of labile non-covalent complexes that are difficult or impossible to observe by conventional MS techniques. The CSI method is particularly suitable for elucidating the structures of labile organometallic compounds in solution as it offers a means to investigate the dynamic behavior of unstable molecules and/or labile clusters in solution. Various labile organic compounds are analyzed by using the CSI method in the field of organic chemistry. CSI-MS is also used to investigate the behavior of aggregated steroid compounds, namely, bisguanidinobenzene-benzoic acid complexes, in solution. This method is a powerful tool for analyzing the equilibria of multiply linked self-assembling catenanes in solution. Its application to unstable and complex supramolecules will be shown. We have developed an effective ionization method that uses metal-complex-based ionization probes containing 2,6-bis(oxazolinyl) pyridine (pybox) ligands. Using this method, we were able to detect multiply charged ions of target molecules. This method was proven to effectively ionize large complex molecules, including biomolecules and various supramolecules, as well as carbon clusters, such as fullerenes. Moreover, isotope-labeled pybox-La complexes were used to clearly detect isotopic labeling shifts. Their applications to

  20. Ionization of cytosine monomer and dimer studied by VUV photoionization and electronic structure calculations

    Energy Technology Data Exchange (ETDEWEB)

    Kostko, Oleg; Bravaya, Ksenia; Krylov, Anna; Ahmed, Musahid

    2009-12-14

    We report a combined theoretical and experimental study of ionization of cytosine monomers and dimers. Gas-phase molecules are generated by thermal vaporization of cytosine followed by expansion of the vapor in a continuous supersonic jet seeded in Ar. The resulting species are investigated by single photon ionization with tunable vacuum-ultraviolet (VUV) synchrotron radiation and mass analyzed using reflectron mass spectrometry. Energy onsets for the measured photoionization efficiency (PIE) spectra are 8.60+-0.05 eV and 7.6+-0.1 eV for the monomer and the dimer, respectively, and provide an estimate for the adiabatic ionization energies (AIE). The first AIE and the ten lowest vertical ionization energies (VIEs) for selected isomers of cytosine dimer computed using equation-of-motion coupled-cluster (EOM-IP-CCSD) method are reported. The comparison of the computed VIEs with the derivative of the PIE spectra, suggests that multiple isomers of the cytosine dimer are present in the molecular beam. The calculations reveal that the large red shift (0.7 eV) of the first IE of the lowest-energy cytosine dimer is due to strong inter-fragment electrostatic interactions, i.e., the hole localized on one of the fragments is stabilized by the dipole moment of the other. A sharp rise in the CH+ signal at 9.20+-0.05 eV is ascribed to the formation of protonated cytosine by dissociation of the ionized dimers. The dominant role of this channel is supported by the computed energy thresholds for the CH+ appearance and the barrierless or nearly barrierless ionization-induced proton transfer observed for five isomers of the dimer.

  1. A prototype ionization profile monitor for RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Connolly, R.; Cameron, P.; Ryan, W. [and others

    1997-07-01

    Transverse beam profiles in the Relativistic Heavy-Ion Collider (RHIC) will be measured with ionization profile monitors (IPM`s). Each IPM collects and measures the distribution of electrons in the beamline resulting from residual gas ionization during bunch passage. The electrons are swept transversely from the beamline and collected on strip anodes oriented parallel to the beam axis. At each bunch passage the charge pulses are amplified, integrated, and digitized for display as a profile histogram. A prototype detector was tested in the injection line during the RHIC Sextant Test. This paper describes the detector and gives results from the beam tests.

  2. Ionization of Atoms by Intense Laser Pulses

    CERN Document Server

    Froehlich, Juerg; Schlein, Benjamin

    2010-01-01

    The process of ionization of a hydrogen atom by a short infrared laser pulse is studied in the regime of very large pulse intensity, in the dipole approximation. Let $A$ denote the integral of the electric field of the pulse over time at the location of the atomic nucleus. It is shown that, in the limit where $|A| \\to \\infty$, the ionization probability approaches unity and the electron is ejected into a cone opening in the direction of $-A$ and of arbitrarily small opening angle. Asymptotics of various physical quantities in $|A|^{-1}$ is studied carefully. Our results are in qualitative agreement with experimental data reported in \\cite{1,2}.

  3. Radiation Generated by Charge Migration Following Ionization

    CERN Document Server

    Kuleff, Alexander I

    2010-01-01

    Electronic many-body effects alone can be the driving force for an ultrafast migration of a positive charge created upon ionization of molecular systems. Here we show that this purely electronic phenomenon generates a characteristic IR radiation. The situation when the initial ionic wave packet is produced by a sudden removal of an electron is also studied. It is shown that in this case a much stronger UV emission is generated. This emission appears as an ultrafast response of the remaining electrons to the perturbation caused by the sudden ionization and as such is a universal phenomenon to be expected in every multielectron system.

  4. Ionization energies along beryllium isoelectronic sequence

    CERN Document Server

    Malyshev, A V; Glazov, D A; Tupitsyn, I I; Shabaev, V M; Plunien, G

    2015-01-01

    Ionization energies for the ground state of berylliumlike ions with nuclear charge numbers in the range Z=16-96 are rigorously evaluated. The calculations merge the ab initio QED treatment in the first and second orders of the perturbation theory in the fine-structure constant $\\alpha$ with the third- and higher-order electron-correlation contributions evaluated within the Breit approximation. The nuclear recoil and nuclear polarization effects are taken into account. The accuracy of the ionization energies obtained has been significantly improved in comparison with previous calculations.

  5. Thermal resistance optimization of GaN/substrate stacks considering thermal boundary resistance and temperature-dependent thermal conductivity

    Science.gov (United States)

    Park, K.; Bayram, C.

    2016-10-01

    Here, we investigate the effects of thermal boundary resistance (TBR) and temperature-dependent thermal conductivity on the thermal resistance of GaN/substrate stacks. A combination of parameters such as substrates {diamond, silicon carbide, silicon, and sapphire}, thermal boundary resistance {10-60 m2K/GW}, heat source lengths {10 nm-20 μm}, and power dissipation levels {1-8 W} are studied by using technology computer-aided design (TCAD) software Synopsys. Among diamond, silicon carbide, silicon, and sapphire substrates, the diamond provides the lowest thermal resistance due to its superior thermal conductivity. We report that due to non-zero thermal boundary resistance and localized heating in GaN-based high electron mobility transistors, an optimum separation between the heat source and substrate exists. For high power (i.e., 8 W) heat dissipation on high thermal conductive substrates (i.e., diamond), the optimum separation between the heat source and substrate becomes submicron thick (i.e., 500 nm), which reduces the hotspot temperature as much as 50 °C compared to conventional multi-micron thick case (i.e., 4 μm). This is attributed to the thermal conductivity drop in GaN near the heat source. Improving the TBR between GaN and diamond increases temperature reduction by our further approach. Overall, we provide thermal management design guidelines for GaN-based devices.

  6. Matrix assisted ionization in vacuum, a sensitive and widely applicable ionization method for mass spectrometry.

    Science.gov (United States)

    Trimpin, Sarah; Inutan, Ellen D

    2013-05-01

    An astonishingly simple new method to produce gas-phase ions of small molecules as well as proteins from the solid state under cold vacuum conditions is described. This matrix assisted ionization vacuum (MAIV) mass spectrometry (MS) method produces multiply charged ions similar to those that typify electrospray ionization (ESI) and uses sample preparation methods that are nearly identical to matrix-assisted laser desorption/ionization (MALDI). Unlike these established methods, MAIV does not require a laser or voltage for ionization, and unlike the recently introduced matrix assisted ionization inlet method, does not require added heat. MAIV-MS requires only introduction of a crystalline mixture of the analyte incorporated with a suitable small molecule matrix compound such as 3-nitrobenzonitrile directly to the vacuum of the mass spectrometer. Vacuum intermediate pressure MALDI sources and modified ESI sources successfully produce ions for analysis by MS with this method. As in ESI-MS, ion formation is continuous and, without a laser, little chemical background is observed. MAIV, operating from a surface offers the possibility of significantly improved sensitivity relative to atmospheric pressure ionization because ions are produced in the vacuum region of the mass spectrometer eliminating losses associated with ion transfer from atmospheric pressure to vacuum. Mechanistic aspects and potential applications for this new ionization method are discussed.

  7. Thermal conductivity and thermal stability of zirconia and hafnia based thermal barrier coatings by EB-PVD for high temperature applications

    Energy Technology Data Exchange (ETDEWEB)

    Singh, J.; Wolfe, D.E.; Miller, R.; Eldridge, J.; Zhu Dong-Ming [Applied Research Lab., Penn State Univ., Univ. Park, PA and NASA-GRC, Cleveland, OH (United States)

    2004-07-01

    Zirconia and hafnia based thermal barrier coating materials were produced by industrial prototype electron beam-physical vapor deposition (EB-PVD). Columnar microstructure of the thermal barrier coatings were modified with controlled microporosity and diffuse sub-interfaces resulting in lower thermal conductivity (20-30% depending up on microporosity volume fraction), higher thermal reflectance (15-20%) and more strain tolerance as compared with standard thermal barrier coatings (TBC). The novel processed coating systems were examined by various techniques including scanning electron microscopy (SEM), X-ray diffraction, and thermal conductivity by laser technique, hemispherical reflectance and thermal cyclic tests. The test results showed the tailored-microstructural TBC offered superior performance over the conventional thermal barrier coatings (ZrO{sub 2} -8 wt.% Y{sub 2}O{sub 3}). (orig.)

  8. [Catheter in the superior vena cava for hemodialysis as a last resort in superior hemithorax].

    Science.gov (United States)

    Restrepo Valencia, C A; Buritica Barragán, C M; Arango, A

    2010-01-01

    We report four patients with chronic kidney disease undergoing haemodialysis therapy, which had exhausted conventional venous access (internal jugular, subclavian) and non-conventional access (axillary, innominate) in the upper hemithorax for haemodialysis. This was primarily due to thrombosis of these veins caused by previous catheterisation. These patients did not qualify for peritoneal dialysis. Using the technique recommended by Archundia et al., 4 indwelling catheters were implanted directly in the superior vena cava in each of the patients with subsequent subcutaneous tunneling. The catheters operated correctly and are currently permeable after being used for an average of 19 months.

  9. Pulsed Discharge Helium Ionization Detector for Highly Sensitive Aquametry.

    Science.gov (United States)

    Mowry, Curtis D; Pimentel, Adam S; Sparks, Elizabeth S; Moorman, Matthew W; Achyuthan, Komandoor E; Manginell, Ronald P

    2016-01-01

    Trace moisture quantitation is crucial in medical, civilian and military applications. Current aquametry technologies are limited by the sample volume, reactivity, or interferences, and/or instrument size, weight, power, cost, and complexity. We report for the first time on the use of a pulsed discharge helium ionization detector (PDHID-D2) (∼196 cm(3)) for the sensitive (limit of detection, 0.047 ng; 26 ppm), linear (r(2) >0.99), and rapid (volume of liquid or gas. The relative humidity sensitivity was 0.22% (61.4 ppmv) with a limit of detection of less than 1 ng moisture with gaseous samples. The sensitivity was 10 to 100 to fold superior to competing technologies without the disadvantages inherent to these technologies. The PDHID-D2, due to its small footprint and low power requirement, has good size, weight, and power-portability (SWAPP) factors. The relatively low cost (∼$5000) and commercial availability of the PDHID-D2 makes our technique applicable to highly sensitive aquametry.

  10. Characterization of interpenetrating networks of acrylic acid (AAc) and N-isopropylacrylamide (NIPAAm) synthesized by ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Adem, E. [Departamento de Fisica Experimental, Instituto de Fisica, Universidad Nacional Autonoma de Mexico, Ciudad Universitaria, Mexico DF 04510 (Mexico); Burillo, G. [Departamento de Quimica de Radiaciones y Radioquimica, Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, Ciudad Universitaria, Mexico DF 04510 (Mexico)], E-mail: burillo@nucleares.unam.mx; Bucio, E. [Departamento de Quimica de Radiaciones y Radioquimica, Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, Ciudad Universitaria, Mexico DF 04510 (Mexico); Magana, C. [Departamento de Fisica Experimental, Instituto de Fisica, Universidad Nacional Autonoma de Mexico, Ciudad Universitaria, Mexico DF 04510 (Mexico); Avalos-Borja, M. [Centro de Nanociencias y Nanotecnologia, Universidad Nacional Autonoma de Mexico, A. Postal 2681, Ensenada, B.C. 22800 (Mexico)

    2009-07-15

    Interpenetrating networks of poly(acrylic acid) (PAAc) and poly(N-isopropylacrylamide) (PNIPAAm) were synthesized in two consecutive steps utilizing ionizing radiation in the first step and chemical reaction in the second step. The first network of PAAc hydrogel was formed by ionizing radiation (gamma or electron beam). The secondary gel of PNIPAAm was synthesized directly within the primary gel of PAAc from an aqueous solution of N-isopropylacrylamide (NIPAAm) containing a crosslinking agent, accelerator and redox initiator. The interpenetrating networks (IPNs) were characterized morphologically by scanning electron microscopy (SEM), and their thermal behavior was analyzed by differential scanning calorimetry (DSC) and thermogravimetry analysis (TGA)

  11. Spacelift 2025 The Supporting Pillar for Space Superiority

    Science.gov (United States)

    1996-08-01

    39 A-1. A Basic Nuclear Thermal Rocket .....................................................................................................44...augmented nuclear thermal rocket combines a scramjet with near-term nuclear thermal rocketry and demonstrates the utility of this concept. 10 Source: Air...Figure A-1. A Basic Nuclear Thermal Rocket The largest obstacles to nuclear rocketry are both political and environmental. Radiation shielding is

  12. Isobutane Made Practical as a Reagent Gas for Chemical Ionization Mass Spectrometry

    Science.gov (United States)

    Newsome, G. Asher; Steinkamp, F. Lucus; Giordano, Braden C.

    2016-11-01

    As a reagent gas for positive- and negative-mode chemical ionization mass spectrometry (CI-MS), isobutane ( i-C4H10) produces superior analyte signal abundance to methane. Isobutane has never been widely adopted for CI-MS because it fouls the ion source more rapidly and produces positive CI spectra that are more strongly dependent on reagent gas pressure compared with methane. Isobutane was diluted to various concentrations in argon for use as a reagent gas with an unmodified commercial gas chromatograph-mass spectrometer. Analyte spectra were directly compared using methane, isobutane, and isobutane/argon mixtures. A mixture of 10% i-C4H10 in argon produced twice the positive-mode analyte signal of methane, equal to pure isobutane, and reduced spectral dependence on reagent gas pressure. Electron capture negative chemical ionization using 1% i-C4H10 in argon tripled analyte signal compared with methane and was reproducible, unlike pure isobutane. The operative lifetime of the ion source using isobutane/argon mixtures was extended exponentially compared with pure isobutane, producing stable and reproducible CI signal throughout. By diluting the reagent gas in an inert buffer gas, isobutane CI-MS experiments were made as practical to use as methane CI-MS experiments but with superior analytical performance.

  13. Late Spectral Evolution of SN 1987A; 1, Temperature and Ionization

    CERN Document Server

    Fransson, C; Fransson, Claes; Kozma, Cecilia

    1997-01-01

    The temperature and ionization of SN 1987A is modeled between 200 and 2000 days in its nebular phase, using a time-dependent model. We include all important elements, as well as the primary composition zones in the supernova. The energy input is provided by radioactive decay of Co-56, Co-57, and Ti-44. The thermalization of the resulting gamma-rays and positrons is calculated by solving the Spencer-Fano equation. Both the ionization and the individual level populations are calculated time-dependently. Adiabatic cooling is included in the energy equation. Charge transfer is important for determining the ionization and is included with available and estimated rates. Full, multilevel atoms are used for the observationally important ions. As input models to the calculations we use explosion models for SN 1987A calculated by Woosley et al and Nomoto et al. The most important result in this paper refers to the evolution of the temperature and ionization of the various abundance zones. The metal-rich core undergoes ...

  14. Penning ionization electron spectroscopy of hydrogen sulfide by metastable helium and neon atoms.

    Science.gov (United States)

    Falcinelli, Stefano; Candori, Pietro; Bettoni, Marta; Pirani, Fernando; Vecchiocattivi, Franco

    2014-08-21

    The dynamics of the Penning ionization of hydrogen sulfide molecules by collision with helium and metastable neon atoms, occurring in the thermal energy range, has been studied by analyzing the energy spectra of the emitted electrons obtained in our laboratory in a crossed beam experiment. These spectra are compared with the photoelectron spectra measured by using He(I) and Ne(I) photons under the same experimental conditions. In this way we obtained the negative energy shifts for the formation of H2S(+) ions in the first three accessible electronic states by He*(2(3,1)S1,0) and Ne*((3)P2,0) Penning ionization collisions: the 2b1 (X̃(2)B1) fundamental one, the first 5a1 (Ã(2)A1), and the second 2b2 (B̃(2)B2) excited states, respectively. The recorded energy shifts indicate that in the case of He* and Ne*-H2S the autoionization dynamics depends on the features of the collision complex and is mainly driven by an effective global attraction that comes from a balance among several non covalent intermolecular interaction components. This suggests that the Penning ionization should take place, in a specific range of intermolecular distances, as we have already observed in the case of Penning ionization of water molecules [Brunetti, B. G.; Candori, P.; Falcinelli, S.; Pirani, F.; Vecchiocattivi, F. J. Chem. Phys. 2013, 139, 164305-1-164305-8].

  15. Radical electronic transformation of strongly coupled plasma at megabar pressure ionization, dielectrization and phase transitions

    Science.gov (United States)

    Fortov, Vladimir

    2007-06-01

    The work presents new results of investigation of pressure and temperature ionization of coupled nonideal plasmas generated as a result of multiple shock compression of metals, H2, He, noble gases, S, I, fullerene C60, H2O in the megabar pressure range. The highly time-resolved diagnostics permit us to measure thermodynamical, radiative and mechanical properties of high pressure condensed matter in a broad region of the phase diagram. This data in combination with exploding wire conductivity measurements demonstrate an ionization rate increase up to ten orders of magnitude as a result of compression of degenerate plasmas at p 104-107 bars. Shock compression of H2, Ar, He, Kr, Ne, Xe in initially gaseous and cryogenic liquid state allows measuring the electrical conductivity, Hall effect parameters, equation of state, and emission spectra of strongly nonideal plasma. Thermal and pressure ionization of strongly coupled states of matter is the most prominent effects under the experimental conditions. It was shown that plasma compression strongly deforms the ionization potentials, emission spectra and scattering cross-sections of the neutrals and ions in the strongly coupled plasmas. In contrast to the plasma compression the multiple shock compression of solid Li, Na, Ca shows ``dielectrization'' of the elements. Phase transitions in strongly nonideal plasmas are discussed.

  16. Properties of Dust Grains in Planetary Nebulae; 1, The Ionized Region of NGC 6445

    CERN Document Server

    Van Hoof, P A M; Beintema, D A; Martin, P G; Pottasch, S R

    1999-01-01

    In this paper we study new infrared spectra of the evolved planetary nebula NGC 6445 obtained with ISO. These data show that the thermal emission from the grains is very cool and has a low flux compared to H beta. A model of the ionized region is constructed, using the photo-ionization code CLOUDY 90.05. Based on this model, we show from depletions in the gas phase elements that little grain destruction can have occurred in the ionized region of NGC 6445. We also argue that dust-gas separation in the nebula is not plausible. The most likely conclusion is that grains are residing inside the ionized region of NGC 6445 and that the low temperature and flux of the grain emission are caused by the low luminosity of the central star and the low optical depth of the grains. This implies that the bulk of the silicon-bearing grains in this nebula were able to survive exposure to hard UV photons for at least several thousands of years, contradicting previously published results. A comparison between optical and infrare...

  17. Fatal pericardial tamponade after superior vena cava stenting.

    NARCIS (Netherlands)

    Ploegmakers, M.J.M.; Rutten, M.J.C.M.

    2009-01-01

    We discuss a fatal complication of percutaneous superior vena cava (SVC) self-expandable stent placement in a patient with superior vena cava syndrome (SVCS). The SVCS was caused by a malignant mediastinal mass with total occlusion of the SVC. Twenty-four hours after the procedure, the patient died

  18. 33 CFR 117.495 - Superior Oil Canal.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Superior Oil Canal. 117.495 Section 117.495 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY BRIDGES DRAWBRIDGE OPERATION REGULATIONS Specific Requirements Louisiana § 117.495 Superior Oil Canal. The draw of the S82 bridge, mile 6.3, in Cameron...

  19. [Superior vena cava syndrome--surgical solution--case report].

    Science.gov (United States)

    Galie, N; Vasile, R; Savu, C; Petreanu, C; Grigorie, V; Tabacu, E

    2010-01-01

    The patient of 52-year-old smoker was admitted in emergency with headaches, dyspnea, oedema and cyanosis of the cephalic extremity and of the superior members. This signs and symptoms suggest a superior vena cava sindrom. Thoracic CT scan shows the thrombosis of the superior vena cava and a tumor localized in the Bariety's Lodge of about 30/40 mm witch is around the right lateral wall of the traheea.This tumor is also tangent to the superior the superior vena cava. The patient was operated by total median sternotomy. By this approach we performed a complete excision of the mediastinal tumor mass. After that we effected a longitudinal cavotomy, we took out the endoluminal clot and we sutured the superior vena cava. The histological diagnosis of the mediastinal tumor was adenocarcinoma tubular-papillary moderately differentiated. The evolution post operative period was favorable the superior vena cava sindrom was a complet remission. The thoracic CT scan control after 9 months later didn't show a local relapse and blood flow was normally throw the superior vena cava.

  20. Fatal pericardial tamponade after superior vena cava stenting.

    NARCIS (Netherlands)

    Ploegmakers, M.J.M.; Rutten, M.J.C.M.

    2009-01-01

    We discuss a fatal complication of percutaneous superior vena cava (SVC) self-expandable stent placement in a patient with superior vena cava syndrome (SVCS). The SVCS was caused by a malignant mediastinal mass with total occlusion of the SVC. Twenty-four hours after the procedure, the patient died

  1. Chemical protection against ionizing radiation. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Livesey, J.C.; Reed, D.J.; Adamson, L.F.

    1984-08-01

    The scientific literature on radiation-protective drugs is reviewed. Emphasis is placed on the mechanisms involved in determining the sensitivity of biological material to ionizing radiation and mechanisms of chemical radioprotection. In Section I, the types of radiation are described and the effects of ionizing radiation on biological systems are reviewed. The effects of ionizing radiation are briefly contrasted with the effects of non-ionizing radiation. Section II reviews the contributions of various natural factors which influence the inherent radiosensitivity of biological systems. Inlcuded in the list of these factors are water, oxygen, thiols, vitamins and antioxidants. Brief attention is given to the model describing competition between oxygen and natural radioprotective substances (principally, thiols) in determining the net cellular radiosensitivity. Several theories of the mechanism(s) of action of radioprotective drugs are described in Section III. These mechanisms include the production of hypoxia, detoxication of radiochemical reactive species, stabilization of the radiobiological target and the enhancement of damage repair processes. Section IV describes the current strategies for the treatment of radiation injury. Likely areas in which fruitful research might be performed are described in Section V. 495 references.

  2. Liquid ionization chambers for LET determination

    DEFF Research Database (Denmark)

    Kaiser, Franz-Joachim; Bassler, Niels; Tölli, Heikki

    Liquid ionization chambers [1] (LICs) have have been used in the last decades as background dosemeters. Since a few years LICs are also commercially available for dosimetry and are used for measurements of dose distributions where a high spatial distribution is necessary. Also in the last decades...

  3. The MICE Demonstration of Muon Ionization Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Lagrange, Jean-Baptiste [Imperial Coll., London; Hunt, Christopher [Imperial Coll., London; Palladino, Vittorio [INFN, Naples; Pasternak, Jaroslaw [Imperial Coll., London

    2016-06-01

    Muon beams of low emittance provide the basis for the intense, well-characterised neutrino beams necessary to elucidate the physics of flavour at the Neutrino Factory and to provide lepton-antilepton collisions up to several TeV at the Muon Collider. The international Muon Ionization Cooling Experiment (MICE) will demonstrate muon ionization cooling, the technique proposed to reduce the phase-space volume occupied by the muon beam at such facilities. In an ionization-cooling channel, the muon beam traverses a material (the absorber) loosing energy, which is replaced using RF cavities. The combined effect is to reduce the transverse emittance of the beam (transverse cooling). The configuration of MICE required to deliver the demonstration of ionization cooling is being prepared in parallel to the execution of a programme designed to measure the cooling properties of liquid-hydrogen and lithium hydride. The design of the cooling-demonstration experiment will be presented together with a summary of the performance of each of its components and the cooling performance of the experiment.

  4. Precision electronics for ionization chamber measurements

    Energy Technology Data Exchange (ETDEWEB)

    Santry, D.C.; Bowes, G.C.; Munzenmayer, K.

    1987-01-01

    By using commercially available units, an electrometer and an IBM personal computer, it was relatively inexpensive and simple to assemble a system which permits ..gamma..-ray-emitting radionuclide activities to be measured in an ionization chamber with an uncertainty of + - 0.5% and a reproducibility of + - 0.05%.

  5. Historical survey of resonance ionization spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Hurst, G.S.

    1984-04-01

    We have recently celebrated the 10th birthday of Resonance Ionization Spectroscopy (RIS), and this seems an appropriate time to review the history of its development. Basically, RIS is a photophysics process in which tunable light sources are used to remove a valence electron from an atom of selected atomic number, Z. If appropriate lasers are used as the light source, one electron can be removed from each atom of the selected Z in the laser pulse. This implies that RIS can be a very efficient, as well as selective, ionization process. In what we normally call RIS, laser schemes are employed which preserve both of these features. In contrast, multiphoton ionization (MPI) is more general, although not necessarily Z selective or very efficient because resonances are often not used. Early research completed in the USSR and described as selective two-step photoionization, employed resonances to ionize the rubidium atom and served to guide work on laser isotope separation. 29 references, 8 figures.

  6. Composite scintillators for detection of ionizing radiation

    Science.gov (United States)

    Dai, Sheng [Knoxville, TN; Stephan, Andrew Curtis [Knoxville, TN; Brown, Suree S [Knoxville, TN; Wallace, Steven A [Knoxville, TN; Rondinone, Adam J [Knoxville, TN

    2010-12-28

    Applicant's present invention is a composite scintillator having enhanced transparency for detecting ionizing radiation comprising a material having optical transparency wherein said material comprises nano-sized objects having a size in at least one dimension that is less than the wavelength of light emitted by the composite scintillator wherein the composite scintillator is designed to have selected properties suitable for a particular application.

  7. Route to direct multiphoton multiple ionization

    NARCIS (Netherlands)

    Lambropoulos, P.; Nikolopoulos, G. M.; Papamihail, K. G.

    2011-01-01

    We address the concept of direct multiphoton multiple ionization in atoms exposed to intense, short-wavelength radiation and explore the conditions under which such processes dominate over the sequential. Their contribution is shown to be quite robust, even under intensity fluctuations and interacti

  8. The Primordial Abundance of Deuterium: Ionization correction

    CERN Document Server

    Cooke, Ryan

    2015-01-01

    We determine the relative ionization of deuterium and hydrogen in low metallicity damped Lyman-alpha (DLA) and sub-DLA systems using a detailed suite of photoionization simulations. We model metal-poor DLAs as clouds of gas in pressure equilibrium with a host dark matter halo, exposed to the Haardt & Madau (2012) background radiation of galaxies and quasars at redshift z~3. Our results indicate that the deuterium ionization correction correlates with the H I column density and the ratio of successive ion stages of the most commonly observed metals. The N(N II) / N(N I) column density ratio provides the most reliable correction factor, being essentially independent of the gas geometry, H I column density, and the radiation field. We provide a series of convenient fitting formulae to calculate the deuterium ionization correction based on observable quantities. The ionization correction typically does not exceed 0.1 per cent for metal-poor DLAs, which is comfortably below the current measurement precision (2...

  9. The GODDESS ionization chamber: developing robust windows

    Science.gov (United States)

    Blanchard, Rose; Baugher, Travis; Cizewski, Jolie; Pain, Steven; Ratkiewicz, Andrew; Goddess Collaboration

    2015-10-01

    Reaction studies of nuclei far from stability require high-efficiency arrays of detectors and the ability to identify beam-like particles, especially when the beam is a cocktail beam. The Gammasphere ORRUBA Dual Detectors for Experimental Structure Studies (GODDESS) is made up of the Oak Ridge-Rutgers University Barrel Array (ORRUBA) of silicon detectors for charged particles inside of the gamma-ray detector array Gammasphere. A high-rate ionization chamber is being developed to identify beam-like particles. Consisting of twenty-one alternating anode and cathode grids, the ionization chamber sits downstream of the target chamber and is used to measure the energy loss of recoiling ions. A critical component of the system is a thin and robust mylar window which serves to separate the gas-filled ionization chamber from the vacuum of the target chamber with minimal energy loss. After construction, windows were tested to assure that they would not break below the required pressure, causing harm to the wire grids. This presentation will summarize the status of the ionization chamber and the results of the first tests with beams. This work is supported in part by the U.S. Department of Energy and National Science Foundation.

  10. IKAR, a ionization chamber for WA9

    CERN Document Server

    1976-01-01

    This ionization chamber arrived at CERN from Leningrad for a high precision study of hadron elastic scattering by a CERN-Clermont-Ferrand-Leningrad-Lyon-Uppsala Collaboration in the H3 beam (WA9). G.A. Korolev (third from right) looks at the drawings.

  11. Fluctuation charge effects in ionization fronts

    Energy Technology Data Exchange (ETDEWEB)

    Arrayas, Manuel; Trueba, Jose L [Area de Electromagnetismo, Universidad Rey Juan Carlos, Camino del Molino s/n, 28943 Fuenlabrada, Madrid (Spain); Baltanas, J P [Departamento de Fisica Aplicada II, Universidad de Sevilla, Av. Reina Mercedes 2, 41012 Sevilla (Spain)

    2008-05-21

    In this paper, we study the effects of charge fluctuations on the propagation of both negative and positive ionization fronts in streamer discharges. We show that fronts accelerate when random charge creation events are present. This effect might play a similar role to photoionization in order to make the front move faster.

  12. Relativistic soliton-like collisionless ionization wave

    Science.gov (United States)

    Arefiev, Alexey; McCormick, Matthew; Quevedo, Hernan; Bengtson, Roger; Ditmire, Todd

    2014-10-01

    It has been observed in recent experiments with laser-irradiated gas jets that a plasma filament produced by the laser and containing energetic electrons can launch a relativistic ionization wave into ambient gas. Here we present a self-consistent theory that explains how a collisionless ionization wave can propagate in a self-sustaining regime. A population of hot electrons necessarily generates a sheath electric field at the plasma boundary. This field penetrates the ambient gas, ionizing the gas atoms and thus causing the plasma boundary to expand. We show that the motion of the newly generated electrons can form a potential well adjacent to the plasma boundary. The outwards motion of the well causes a bunch of energetic electrons to become trapped, while allowing the newly generated electrons to escape into the plasma without retaining much energy. The resulting soliton-like ionizing field structure propagates outwards with a bunch of hot electrons that maintain a strong sheath field despite significant plasma expansion. We also present 1D and 2D particle-in-cell simulations that illustrate the described mechanism. The simulations were performed using HPC resources provided by the Texas Advanced Computing Center. This work was supported by NNSA Contract No. DE-FC52-08NA28512 and U.S. DOE Contract No. DE-FG02-04ER54742.

  13. Properties of Excitons Bound to Ionized Donors

    DEFF Research Database (Denmark)

    Skettrup, Torben; Suffczynski, M.; Gorzkowski, W.

    1971-01-01

    Binding energies, interparticle distances, oscillator strengths, and exchange corrections are calculated for the three-particle complex corresponding to an exciton bound to an ionized donor. The results are given as functions of the mass ratio of the electron and hole. Binding of the complex is o...

  14. Positronium impact ionization of Alkali atoms

    CERN Document Server

    Ghosh, D

    2015-01-01

    Target ionization processes of alkali atoms by Positronium impact are investigated. Calculations are performed in the frame work of model potential formalism using the Coulomb distorted eikonal approximation. Interesting qualitative features are noted both in the scattered Ps and the ejected electron distributions in differential as well as double differential levels of the collision cross sections.

  15. Vacancy rearrangement processes in multiply ionized atoms

    Energy Technology Data Exchange (ETDEWEB)

    Czarnota, M [Institute of Physics, Swietokrzyska Academy, 25-406 Kielce (Poland); Pajek, M [Institute of Physics, Swietokrzyska Academy, 25-406 Kielce (Poland); Banas, D [Institute of Physics, Swietokrzyska Academy, 25-406 Kielce (Poland); Dousse, J-Cl [Physics Department, University of Fribourg, CH-1700 Fribourg (Switzerland); Maillard, Y-P [Physics Department, University of Fribourg, CH-1700 Fribourg (Switzerland); Mauron, O [Physics Department, University of Fribourg, CH-1700 Fribourg (Switzerland); Raboud, P A [Physics Department, University of Fribourg, CH-1700 Fribourg (Switzerland); Berset, M [Physics Department, University of Fribourg, CH-1700 Fribourg (Switzerland); Hoszowska, J [European Synchrotron Radiation Facility (ESRF), F-38043 Grenoble (France); Slabkowska, K [Faculty of Chemistry, Nicholas Copernicus University, 87-100 Torun (Poland); Polasik, M [Faculty of Chemistry, Nicholas Copernicus University, 87-100 Torun (Poland); Chmielewska, D [Soltan Institute for Nuclear Studies, 05-400 Otwock-Swierk (Poland); Rzadkiewicz, J [Soltan Institute for Nuclear Studies, 05-400 Otwock-Swierk (Poland); Sujkowski, Z [Soltan Institute for Nuclear Studies, 05-400 Otwock-Swierk (Poland)

    2007-03-01

    We demonstrate that in order to interpret the x-ray satellite structure of Pd L{alpha}{sub 1,2}(L{sub 3}M{sub 4,5}) transitions excited by fast O ions, which was measured using a high-resolution von Hamos crystal spectrometer, the vacancy rearrangement processes, taking place prior to the x-ray emission, have to be taken into account. The measured spectra were compared with the predictions of the multi-con.guration Dirac-Fock (MCDF) calculations using the fluorescence and Coster-Kronig yields which were modiffed due to a reduced number of electrons available for relaxation processes and the effect of closing the Coster-Kronig transitions. We demonstrate that the vacancy rearrangement processes can be described in terms of the rearrangement factor, which can be calculated by solving the system of rate equations modelling the flow of vacancies in the multiply ionized atom. By using this factor, the ionization probability at the moment of collision can be extracted from the measured intensity distribution of x-ray satellites. The present results support the independent electron picture of multiple ionization and indicate the importance of use of Dirac-Hartree-Fock wave functions to calculate the ionization probabilities.

  16. Roles of ionizing radiation in cell transformation

    Energy Technology Data Exchange (ETDEWEB)

    Tobias, C.A.; Albright, N.W.; Yang, T.C.

    1983-07-01

    Earlier the authors described a repair misrepair model (RMR-I) which is applicable for radiations of low LET, e.g., x rays and gamma rays. RMR-II was described later. Here is introduced a mathematical modification of the RMR model, RMR-III, which is intended to describe lethal effects caused by heavily ionizing tracks. 31 references, 4 figures.

  17. Salt Tolerance of Desorption Electrospray Ionization (DESI)

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, Ayanna U. [Purdue University; Talaty, Nari [Purdue University; Cooks, R G [Purdue University; Van Berkel, Gary J [ORNL

    2007-01-01

    Suppression of ion intensity in the presence of high salt matrices is common in most mass spectrometry ionization techniques. Desorption electrospray ionization (DESI) is an ionization method that exhibits salt tolerance, and this is investigated. DESI analysis was performed on three different drug mixtures in the presence of 0, 0.2, 2, 5, 10, and 20% NaCl:KCl weight by volume from seven different surfaces. At physiological concentrations individual drugs in each mixture were observed with each surface. Collision-induced dissociation (CID) was used to provide additional confirmation for select compounds. Multiple stage experiments, to MS5, were performed for select compounds. Even in the absence of added salt, the benzodiazepine containing mixture yielded sodium and potassium adducts of carbamazepine which masked the ions of interest. These adducts were eliminated by adding 0.1% 7M ammonium acetate to the standard methanol:water (1:1) spray solvent. Comparison of the salt tolerance of DESI with that of electrospray ionization (ESI) demonstrated much better signal/noise characteristics for DESI in this study. The salt tolerance of DESI was also studied by performing limit of detection and dynamic range experiments. Even at a salt concentration significantly above physiological concentrations, select surfaces were effective in providing spectra that allowed the ready identification of the compounds of interest. The already high salt tolerance of DESI can be optimized further by appropriate choices of surface and spray solution.

  18. The Origin of High Thermal Conductivity and Ultralow Thermal Expansion in Copper-Graphite Composites.

    Science.gov (United States)

    Firkowska, Izabela; Boden, André; Boerner, Benji; Reich, Stephanie

    2015-07-08

    We developed a nanocomposite with highly aligned graphite platelets in a copper matrix. Spark plasma sintering ensured an excellent copper-graphite interface for transmitting heat and stress. The resulting composite has superior thermal conductivity (500 W m(-1) K(-1), 140% of copper), which is in excellent agreement with modeling based on the effective medium approximation. The thermal expansion perpendicular to the graphite platelets drops dramatically from ∼20 ppm K(-1) for graphite and copper separately to 2 ppm K(-1) for the combined structure. We show that this originates from the layered, highly anisotropic structure of graphite combined with residual stress under ambient conditions, that is, strain-engineering of the thermal expansion. Combining excellent thermal conductivity with ultralow thermal expansion results in ideal materials for heat sinks and other devices for thermal management.

  19. The MICE Demonstration of Ionization Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Pasternak, J.; Blackmore, V.; Hunt, C.; Lagrange, J-B.; Long, K.; Collomb, N.; Snopok, P.

    2015-05-01

    Muon beams of low emittance provide the basis for the intense, well-characterised neutrino beams necessary to elucidate the physics of flavour at the Neutrino Factory and to provide lepton-antilepton collisions at energies of up to several TeV at the Muon Collider. The International Muon Ionization Cooling Experiment (MICE) will demonstrate ionization cooling, the technique by which it is proposed to reduce the phase-space volume occupied by the muon beam at such facilities. In an ionization cooling channel, the muon beam passes through a material (the absorber) in which it loses energy. The energy lost is then replaced using RF cavities. The combined effect of energy loss and re-acceleration is to reduce the transverse emittance of the beam (transverse cooling). A major revision of the scope of the project was carried out over the summer of 2014. The revised project plan, which has received the formal endorsement of the international MICE Project Board and the international MICE Funding Agency Committee, will deliver a demonstration of ionization cooling by September 2017. In the revised configuration a central lithium-hydride absorber provides the cooling effect. The magnetic lattice is provided by the two superconducting focus coils and acceleration is provided by two 201 MHz single-cavity modules. The phase space of the muons entering and leaving the cooling cell will be measured by two solenoidal spectrometers. All the superconducting magnets for the ionization cooling demonstration are available at the Rutherford Appleton Laboratory and the first single-cavity prototype is under test in the MuCool Test Area at Fermilab. The design of the cooling demonstration experiment will be described together with a summary of the performance of each of its components. The cooling performance of the revised configuration will also be presented.

  20. Nucleation in an Ultra Low Ionization Environment

    Science.gov (United States)

    Pedersen, J. O.; Enghoff, M. B.; Paling, S.; Svensmark, H.

    2010-12-01

    Atmospheric ions can enhance the nucleation of aerosols, as has been established by experiments, observation, and theory. In the clean marine atmosphere ionization is mainly caused by cosmic rays which in turn are controlled by the activity of the Sun, thus providing a potential link between solar activity and climate. In order to understand the effect ions may have on the production of cloud condensation nuclei the overall contribution of ion induced nucleation to the global production of secondary aerosols must be determined. One issue with determining this contribution is that several mechanisms for nucleation exist and it can be difficult to determine the relative importance of the various mechanisms in a given nucleation event when both ion induced and electrically neutral nucleation mechanisms are at work at the same time. We have carried out nucleation experiments in the Boulby Underground Laboratory, located 1100 meters below ground, thus reducing the flux of ionizing cosmic radiation by six orders of magnitude. Similarly we have reduced the gamma background by shielding the experiment in lead and copper. Finally we have used air stored for several weeks and passed through an active charcoal filter in order to reduce the Radon concentration. In this way we have been able to make nucleation experiments with very low ionizing background, meaning that we can rule out ion induced nucleation as a contributing mechanism. Our experimental setup is a 50 L electropolished stainless steel reactor at near atmospheric conditions. The chamber contains clean air with the addition of water vapor, ozone, and SO2. Using UV lights at 254 nm ozone is photolyzed, leading to the production of sulfuric acid and thus aerosols. An 18 MBq Caesium-137 gamma ray source with various amounts of lead in front allows us to alter the ionization in our chamber. By making series of nucleation bursts with varying amounts of ionizing radiation we then gauge the relative importance of ion

  1. Ionization of amphiphilic acidic block copolymers.

    Science.gov (United States)

    Colombani, Olivier; Lejeune, Elise; Charbonneau, Céline; Chassenieux, Christophe; Nicolai, Taco

    2012-06-28

    The ionization behavior of an amphiphilic diblock copolymer poly(n-butyl acrylate(50%)-stat-acrylic acid(50%))(100)-block-poly(acrylic acid)(100) (P(nBA(50%)-stat-AA(50%))(100)-b-PAA(100), DH50) and of its equivalent triblock copolymer P(nBA(50%)-stat-AA(50%))(100)-b-PAA(200)-b-P(nBA(50%)-stat-AA(50%))(100) (TH50) were studied by potentiometric titration either in pure water or in 0.5 M NaCl. These polymers consist of a hydrophilic acidic block (PAA) connected to a hydrophobic block, P(nBA(50%)-stat-AA(50%))(100), whose hydrophobic character has been mitigated by copolymerization with hydrophilic units. We show that all AA units, even those in the hydrophobic block could be ionized. However, the AA units within the hydrophobic block were less acidic than those in the hydrophilic block, resulting in the preferential ionization of the latter block. The preferential ionization of PAA over that of P(nBA(50%)-stat-AA(50%))(100) was stronger at higher ionic strength. Remarkably, the covalent bonds between the PAA and P(nBA(50%)-stat-AA(50%))(100) blocks in the diblock or the triblock did not affect the ionization of each block, although the self-association of the block copolymers into spherical aggregates modified the environment of the PAA blocks compared to when PAA was molecularly dispersed.

  2. Measurement of the first ionization potential of astatine by laser ionization spectroscopy

    CERN Document Server

    Rothe, S; Antalic, S; Borschevsky, A; Capponi, L; Cocolios, T E; De Witte, H; Eliav, E; Fedorov, D V; Fedosseev, V N; Fink, D A; Fritzsche, S; Ghys, L; Huyse, M; Imai, N; Kaldor, U; Kudryavtsev, Yu; Köster, U; Lane, J; Lassen, J; Liberati, V; Lynch, K M; Marsh, B A; Nishio, K; Pauwels, D; Pershina, V; Popescu, L; Procter, T J; Radulov, D; Raeder, S; Rajabali, M M; Rapisarda, E; Rossel, R E; Sandhu, K; Seliverstov, M D; Sjödin, A M; Van den Bergh, P; Van Duppen, P; Venhart, M; Wakabayashi, Y; Wendt K D A

    2013-01-01

    The radioactive element astatine exists only in trace amounts in nature. Its properties can therefore only be explored by study of smallest quantities of artificially produced isotopes or by performing theoretical calculations. One of the most important properties influencing the chemical behaviour is the energy required to remove one electron from the valence shell, referred to as the ionization potential. Here we use laser spectroscopy to probe the optical spectrum of astatine near the ionization threshold. The observed series of Rydberg states enabled the first determination of the ionization potential of the astatine atom, 9.317510(8) eV. New ab initio calculations were performed to support the experimental result. The measured value serves as a benchmark for quantum chemistry calculations of the properties of astatine as well as for the theoretical prediction of the ionization potential of super-heavy element 117, the heaviest homologue of astatine.

  3. Amplitude distribution of ionization jerks in ionization-chamber ASK-1 according long-term measurements

    Science.gov (United States)

    Timofeev, Vladislav

    2016-07-01

    As part of the Yakut complex systems by measuring the intensity of cosmic rays has a unique device spherical - ionization chamber ASK-1 with a lead screen thickness of 12 cm. The camera allows you to explore the physical characteristics of the so-called "ionization jerks " - sharp increases ionization current caused by the passage through the device much ionizing particles of cosmic origin. Due to a large increase in current nuclear cascade "showers", formed mainly by particles of cosmic rays in the camera screen. Over the entire period of observation (50 years old) camera ASK-1 was registered 59125 aftershocks. Their nature and properties still does not sufficiently studied, especially in medium and large amplitudes.

  4. The role of Upper Hybrid Turbulence on HF Artificial Ionization

    Science.gov (United States)

    Papadopoulos, Konstantinos Dennis; Najmi, Amir; Eliasson, Bengt; Milikh, Gennady

    2016-07-01

    -number spectral region at the at the UH frequency 2. Excitation of all Bernstein modes associated with cyclotron frequency harmonics both below and above the UH frequency for both the resonant and non0resonant cases. 3. Moderate electron heating, in the form of bulk heating caused by first Bernstein mode, although its wave intensity is more than 20 dB lower than the intensity of the UH branch for all non-resonant cases. 4. Strong generation of non-thermal tails for the resonant cases, by the UH waves downshifted by the lower hybrid frequency when the downshifted frequency was equal to an harmonic of the electron gyro-frequency. The new UH turbulence resolves several f the mysteries associated with artificial ionization and suggests several new observations. Acknowledgment:Work supported by AFOSR MURI grant FA95501410019.

  5. The superior transvelar approach to the fourth ventricle and brainstem.

    Science.gov (United States)

    Ezer, Haim; Banerjee, Anirban Deep; Bollam, Papireddy; Guthikonda, Bharat; Nanda, Anil

    2012-06-01

    Objective The superior transvelar approach is used to access pathologies located in the fourth ventricle and brainstem. The surgical path is below the venous structures, through the superior medullary velum. Following splitting the tentorial edge, near the tentorial apex, the superior medullary velum is split in the cerebello-mesencephalic fissure. Using the supracerebellar infratentorial, transtentorial or parietal interhemispheric routes, the superior medullary velum is approached. Splitting this velum provides a detailed view of the fourth ventricle and its floor. Materials and Methods A total of 10 formalin-fixed specimens were dissected in a stepwise manner to simulate the superior transvelar approach to the fourth ventricle. The exposure gained the distance from the craniotomy site and the ease of access was assessed for each of the routes. We also present an illustrative case, operated by the senior author (AN). Results The superior transvelar approach provides access to the entire length of the fourth ventricle floor, from the aqueduct to the obex, when using the parietal interhemispheric route. In addition, this approach provides access to the entire width of the floor of the fourth ventricle; however, this requires retracting the superior cerebellar peduncle. Using the supracerebellar infratentorial route gives a limited exposure of the superior part of the fourth ventricle. The occipital interhemispheric route is a compromise between these two. Conclusion The superior transvelar approach to the fourth ventricle provides a route for approaching the fourth ventricle from above. This approach does not require opening the posterior fossa in the traditional way, and provides a reasonable alternative for accessing the superior fourth ventricle.

  6. Thermal comfort

    DEFF Research Database (Denmark)

    d’Ambrosio Alfano, Francesca Romana; Olesen, Bjarne W.; Palella, Boris Igor;

    2014-01-01

    Thermal comfort is one of the most important aspects of the indoor environmental quality due to its effects on well-being, people's performance and building energy requirements. Its attainment is not an easy task requiring advanced design and operation of building and HVAC systems, taking...... into account all parameters involved. Even though thermal comfort fundamentals are consolidated topics for more than forty years, often designers seem to ignore or apply them in a wrong way. Design input values from standards are often considered as universal values rather than recommended values to be used...... under specific conditions. At operation level, only few variables are taken into account with unpredictable effects on the assessment of comfort indices. In this paper, the main criteria for the design and assessment of thermal comfort are discussed in order to help building and HVAC systems designers...

  7. Review of health effects of non-ionizing radiations | Ughachukwu ...

    African Journals Online (AJOL)

    Non-ionizing radiations (electromagnetic waves) consist of electric and ... There are conflicting research reports concerning the safety of non-ionizing radiations. ... There is need, therefore, to increase public awareness on the dangers of ...

  8. Fully differential cross sections for heavy particle impact ionization

    Energy Technology Data Exchange (ETDEWEB)

    McGovern, M; Walters, H R J [Department of Applied Mathematics and Theoretical Physics, Queen' s University, Belfast BT7 1NN (United Kingdom); Assafrao, D; Mohallem, J R [Laboratorio de Atomos e Moleculas Especiais, Departamento de Fisica, ICEx, Universidade Federal de Minas Gerais, P.O Box 702, 30123-970 Belo Horizonte, MG (Brazil); Whelan, Colm T, E-mail: mmcgovern06@qub.ac.u [Department of Physics, Old Dominion University, Norfolk, VA 23529-0116 (United States)

    2009-11-15

    We describe a procedure for extracting fully differential ionization cross sections from an impact parameter coupled pseudostate treatment of the collision. Some examples from antiproton impact ionization of atomic Hydrogen are given.

  9. Ground Levels and Ionization Energies for the Neutral Atoms

    Science.gov (United States)

    SRD 111 Ground Levels and Ionization Energies for the Neutral Atoms (Web, free access)   Data for ground state electron configurations and ionization energies for the neutral atoms (Z = 1-104) including references.

  10. Non-Ionizing Radiation Used in Microwave Ovens

    Science.gov (United States)

    ... in Microwave Ovens Non-Ionizing Radiation Used in Microwave Ovens Explore the interactive, virtual community of RadTown USA ! ... learn more About Non-Ionizing Radiation Used in Microwave Ovens Microwave Oven. Microwave ovens use electromagnetic waves that ...

  11. Thermal plasmas: fundamental aspects; Plasmas thermiques: aspects fondamentaux

    Energy Technology Data Exchange (ETDEWEB)

    Fauchais, P. [Limoges Univ. Faculte des Sciences, Lab. Science des Procedes Ceramiques et Traitements de Surface (SPCTS-UMR-6638-CNRS), 87 (France)

    2005-10-01

    This article treats of thermal plasmas, i.e. mainly produced by electric arcs and RF discharges. Their main characteristic is that they are generated at a pressure close to the atmospheric pressure (between 10{sup 4} and 10{sup 6} Pa) and refer to the classical kinetics of the Boltzmann equation. Because of the pressure, the collisions between particles are numerous and ionization is mainly due to a thermal effect. They correspond to electron densities between 10{sup 20} and 10{sup 24} m{sup -3} and temperatures between 6000 and 25000 K. In these plasmas, the electric fields and the average free trajectories are too weak to generate a ionization state by direct inelastic collision. Ionization is thus essentially a thermal phenomenon due to elastic collisions. This article presents: 1 - the particles present in a plasma: definition, energy states; 2 - characteristic data: collisions, average free path and collision cross-section, distribution function, ionization types, charged particles mobility inside an electric field, scattering, Debye length; 3 - plasmas at the thermodynamical equilibrium: conditions of equilibrium, calculation of composition, thermodynamic properties, transport properties, radiation; 4 - thermal plasmas away from equilibrium: conditions of non-equilibrium, calculation of plasma composition, calculation of transport properties, quenching phenomenon. (J.S.)

  12. Matrix Thermalization

    CERN Document Server

    Craps, Ben; Nguyen, Kévin

    2016-01-01

    Matrix quantum mechanics offers an attractive environment for discussing gravitational holography, in which both sides of the holographic duality are well-defined. Similarly to higher-dimensional implementations of holography, collapsing shell solutions in the gravitational bulk correspond in this setting to thermalization processes in the dual quantum mechanical theory. We construct an explicit, fully nonlinear supergravity solution describing a generic collapsing dilaton shell, specify the holographic renormalization prescriptions necessary for computing the relevant boundary observables, and apply them to evaluating thermalizing two-point correlation functions in the dual matrix theory.

  13. Scintillation properties of semiconducting 6LiInSe2 crystals to ionizing radiation

    Science.gov (United States)

    Wiggins, Brenden; Groza, Michael; Tupitsyn, Eugene; Lukosi, Eric; Stassun, Keivan; Burger, Arnold; Stowe, Ashley

    2015-11-01

    6LiInSe2 has gained attention recently as a semiconducting thermal neutron detector. As presented herein, the chalcogenide compound semiconductor also detects incident neutrons via scintillation, making 6LiInSe2 the only lithium containing semiconductor to respond to neutrons via both detection mechanisms. Both yellow and red crystals, which appear in the literature, were investigated. Only the yellow crystal responded favorably to ionizing radiation, similar to the semiconducting operation utilizing electrodes. The obtained light yield for yellow crystals is 4400 photons/MeV, referenced to Bi4Ge3O12 (BGO).The estimated thermal neutron light yield was 21,000 photons/thermal neutron. The two measured decay time components were found to be 31±1 ns (49%) and 143±9 ns (51%).This crystal provides efficient, robust detection of neutrons via scintillation with respectable light yield and rapid response, enabling its use for a broad array of neutron detection applications.

  14. COLLISIONLESS SHOCKS IN A PARTIALLY IONIZED MEDIUM. II. BALMER EMISSION

    Energy Technology Data Exchange (ETDEWEB)

    Morlino, G.; Bandiera, R.; Blasi, P.; Amato, E. [INAF-Osservatorio Astrofisico di Arcetri, Largo E. Fermi 5, I-50125 Firenze (Italy)

    2012-12-01

    Strong shocks propagating into a partially ionized medium are often associated with optical Balmer lines. This emission is due to impact excitation of neutral hydrogen by hot protons and electrons in the shocked gas. The structure of such Balmer-dominated shocks has been computed in a previous paper, where the distribution function of neutral particles was derived from the appropriate Boltzmann equation including coupling with ions and electrons through charge exchange and ionization. This calculation showed how the presence of neutrals can significantly modify the shock structure through the formation of a neutral-induced precursor ahead of the shock. Here we follow up on our previous work and investigate the properties of the resulting Balmer emission, with the aim of using the observed radiation as a diagnostic tool for shock parameters. Our main focus is on supernova remnant shocks, and we find that, for typical parameters, the H{alpha} emission typically has a three-component spectral profile, where (1) a narrow component originates from upstream cold hydrogen atoms, (2) a broad component comes from hydrogen atoms that have undergone charge exchange with shocked protons downstream of the shock, and (3) an intermediate component is due to hydrogen atoms that have undergone charge exchange with warm protons in the neutral-induced precursor. The relative importance of these three components depends on the shock velocity, on the original degree of ionization, and on the electron-ion temperature equilibration level. The intermediate component, which is the main signature of the presence of a neutral-induced precursor, becomes negligible for shock velocities {approx}< 1500 km s{sup -1}. The width of the intermediate line reflects the temperature in the precursor, while the width of the narrow one is left unaltered by the precursor. In addition, we show that the profiles of both the intermediate and broad components generally depart from a thermal distribution, as a

  15. Smart ionization chamber for gamma-ray monitoring

    OpenAIRE

    Drndarević Vujo R.; Jevtić Nenad J.; Rajović Vladimir M.; Stanković Srboljub J.

    2014-01-01

    A design and implementation of a smart ionization chamber suitable for connection into gamma radiation monitoring networks is presented in this paper. The smart ionization chamber consists of air-equivalent one liter ionization chamber with associated electronics and a built-in memory for storage of electronic data specifications. Generally, operating and measurement characteristics of the used ionization chamber are written into the memory chip attached to...

  16. High-Order Harmonic Generation in the Ionization Process

    Institute of Scientific and Technical Information of China (English)

    CHEN Jing; CHEN Shi-Gang; LIU Jie

    2000-01-01

    Based on the nonperturbative quantum electrodynamics scattering theory for multiphoton ionization developed recently, high-order harmonic generated in the ionization process is discussed. The influence of the Coulomb potential is treated as a perturbation in the expansion of the transition matrix. It is deduced that the harmonic photons are emitted in the resonant process during ionization and the width of the harmonic peaks is just the ionization rate of the atom.

  17. Mutational signatures of ionizing radiation in second malignancies

    OpenAIRE

    Behjati, Sam; Gundem, Gunes; Wedge, David C.; Roberts, Nicola D.; Tarpey, Patrick S.; Cooke, Susanna L; Van Loo, Peter; Alexandrov, Ludmil B; Ramakrishna, Manasa; Davies, Helen; Nik-Zainal, Serena; Hardy, Claire; Latimer, Calli; Raine, Keiran M.; Stebbings, Lucy

    2016-01-01

    Ionizing radiation is a potent carcinogen, inducing cancer through DNA damage. The signatures of mutations arising in human tissues following in vivo exposure to ionizing radiation have not been documented. Here, we searched for signatures of ionizing radiation in 12 radiation-associated second malignancies of different tumour types. Two signatures of somatic mutation characterize ionizing radiation exposure irrespective of tumour type. Compared with 319 radiation-naive tumours, radiation-ass...

  18. Ionization of food products. Ionisation des produits alimentaires

    Energy Technology Data Exchange (ETDEWEB)

    Vasseur, J.P.

    1991-01-01

    After general remarks on foods preservation, on international works and on ionization future prospects, main irradiation sources are described. Recalls on radioactivity, on radiation-matter interaction, on toxicology of ionized foods and on ionized foods detection are given. Ionization applications to various products are reviewed, especially in: - Poultry meat - Fishing products - Fresh fruits and vegetables - Dry fruits and vegetables - spices, tea, infusion - prepacked products... An evaluation of economics and sociocultural impacts is presented in connection with recent experiments.

  19. Single and double ionization of gallium by electron impact

    Indian Academy of Sciences (India)

    L K Jha

    2002-09-01

    Electron impact single and double ionization cross sections of gallium have been calculated in the binary encounter approximation using accurate expression for including exchange and interference as given by Vriens and Hartree–Fock velocity distributions for the target electrons throughout the calculations. It is concluded that the ionization of 3d shell contributes partly to single ionization and partly to double ionization. The results so obtained show reasonably good agreement with the experimental data.

  20. A mechanism for ionization of nonvolatile compounds in mass spectrometry: considerations from MALDI and inlet ionization.

    Science.gov (United States)

    Trimpin, Sarah; Wang, Beixi; Inutan, Ellen D; Li, Jing; Lietz, Christopher B; Harron, Andrew; Pagnotti, Vincent S; Sardelis, Diana; McEwen, Charles N

    2012-10-01

    Mechanistic arguments relative to matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) address observations that predominately singly charged ions are detected. However, recently a matrix assisted laser ablation method, laserspray ionization (LSI), was introduced that can use the same sample preparation and laser as MALDI, but produce highly charged ions from proteins. In MALDI, ions are generated from neutral molecules by the photon energy provided to a matrix, while in LSI ions are produced inside a heated inlet tube linking atmospheric pressure and the first vacuum region of the mass spectrometer. Some LSI matrices also produce highly charged ions with MALDI ion sources operated at intermediate pressure or high vacuum. The operational similarity of LSI to MALDI, and the large difference in charge states observed by these methods, provides information of fundamental importance to proposed ionization mechanisms for LSI and MALDI. Here, we present data suggesting that the prompt and delayed ionization reported for vacuum MALDI are both fast processes relative to producing highly charged ions by LSI. The energy supplied to produce these charged clusters/droplets as well as their size and time available for desolvation are determining factors in the charge states of the ions observed. Further, charged droplets/clusters may be a common link for ionization of nonvolatile compounds by a variety of MS ionization methods, including MALDI and LSI.

  1. New Constraints on the Escape of Ionizing Photons From Starburst Galaxies Using Ionization-Parameter Mapping

    CERN Document Server

    Zastrow, Jordan; Veilleux, Sylvain; McDonald, Michael

    2013-01-01

    The fate of ionizing radiation in starburst galaxies is key to understanding cosmic reionization. However, the galactic parameters on which the escape fraction of ionizing radiation depend are not well understood. Ionization-parameter mapping provides a simple, yet effective, way to study the radiative transfer in starburst galaxies. We obtain emission-line ratio maps of [SIII]/[SII] for six, nearby, dwarf starbursts: NGC 178, NGC 1482, NGC 1705, NGC 3125, NGC 7126, and He 2-10. The narrow-band images are obtained with the Maryland-Magellan Tunable Filter at Las Campanas Observatory. Using these data, we previously reported the discovery of an optically thin ionization cone in NGC 5253, and here we also discover a similar ionization cone in NGC 3125. This latter cone has an opening angle of 40+/-5 degrees (0.4 ster), indicating that the passageways through which ionizing radiation may travel correspond to a small solid angle. Additionally, there are three sample galaxies that have winds and/or superbubble act...

  2. Atmospheric Pressure Ionization Using a High Voltage Target Compared to Electrospray Ionization

    Science.gov (United States)

    Lubin, Arnaud; Bajic, Steve; Cabooter, Deirdre; Augustijns, Patrick; Cuyckens, Filip

    2016-11-01

    A new atmospheric pressure ionization (API) source, viz. UniSpray, was evaluated for mass spectrometry (MS) analysis of pharmaceutical compounds by head-to-head comparison with electrospray ionization (ESI) on the same high-resolution MS system. The atmospheric pressure ionization source is composed of a grounded nebulizer spraying onto a high voltage, cylindrical stainless steel target. Molecules are ionized in a similar fashion to electrospray ionization, predominantly producing protonated or deprotonated species. Adduct formation (e.g., proton and sodium adducts) and in-source fragmentation is shown to be almost identical between the two sources. The performance of the new API source was compared with electrospray by infusion of a mix of 22 pharmaceutical compounds with a wide variety of functional groups and physico-chemical properties (molecular weight, logP, and pKa) in more than 100 different conditions (mobile phase strength, solvents, pH, and flow rate). The new API source shows an intensity gain of a factor 2.2 compared with ESI considering all conditions on all compounds tested. Finally, some hypotheses on the ionization mechanism, similarities, and differences with ESI, are discussed.

  3. A nanoscale soft-ionization membrane: A novel ionizer for ion mobility spectrometers for space applications

    Science.gov (United States)

    Hartley, Frank T.; Kanik, Isik

    2002-11-01

    The Jet Propulsion Laboratory (JPL) has developed a novel nanometer-thick "Soft Ionization Membrane" (SIM) which is capable of ionizing nearly 100% of the gases that pass through it. Both sides of the membrane are coated with a metallic conducting film. A modest potential of less than 10 Volts across the membrane produces an electric field in excess of 107 V/cm over a region that is smaller than the mean free path of gas molecules which ionizes the neutral molecules that passing through. Because the region of high electric field is smaller than the mean free path of gas molecules, there are virtually no high energy collisions and the system does not suffer from the fatal problem of avalanche breakdown. The soft ionization mechanism does not fracture the medium or cause any secondary ionization. Thus, a truly new ionization technique is enabled by a simple nanoscale micromachined device. The SIM is tiny, rugged and well suited for a wide variety of applications ranging from space micropropulsion systems to miniature analytical separation devices. In this paper we focus our attention on ion mobility spectrometers (IMSs) as a potential candidate to be incorporated with SIM.

  4. Síndrome de Deiscência de Canal Semicircular Superior Superior Canal Dehiscence Syndrome

    Directory of Open Access Journals (Sweden)

    Suzane da Cunha Ferreira

    2006-06-01

    Full Text Available A Síndrome de Deiscência de Canal Semicircular Superior (SDCSS, primeiramente descrita em 1998 por Minor et al., caracteriza-se por vertigem associada à presença de nistagmo, relacionados à exposição a estímulos sonoros intensos ou a modificações de pressão dentro da orelha média ou intracraniana. Disacusia, em sua maioria de padrão condutivo à audiometria tonal, também pode estar presente. Nesta revisão da literatura objetivou-se abordar a SDCSS, com seus principais sinais e sintomas, achados diagnósticos e tratamento, assim como enfatizar a importância de sua inclusão dentre as causas de vertigem, visto tratar-se de acometimento ainda pouco conhecido até mesmo entre especialistas. O diagnóstico correto, além de possibilitar seu tratamento, impede que abordagens diagnósticas e terapêuticas inapropriadas sejam realizadas.The Superior Canal Dehiscence Syndrome (SCDS was first reported by Minor at. Al. (1998, and has been characterized by vertigo and vertical-torsional eye movements related to loud sounds or stimuli that change middle ear or intracranial pressure. Hearing loss, for the most part with conductive patterns on audiometry, may be present in this syndrome. We performed a literature survey in order to to present symptoms, signs, diagnostic and therapeutic approaches to the SCDS, also aiming at stressing the great importance of including this syndrome among the tractable cause of vertigo. We should emphasize that this is a recent issue, still unknown by some specialists. The Correct SCDS diagnosis, besides enabling patient treatment, precludes misdiagnosis and inadequate therapeutic approaches.

  5. Core-shell polymeric microcapsules with superior thermal and solvent stability.

    Science.gov (United States)

    Kang, Sen; Baginska, Marta; White, Scott R; Sottos, Nancy R

    2015-05-27

    A protective polydopamine (PDA) coating is applied to core-shell microcapsule surfaces by the polymerization of dopamine monomers. A neutral aqueous solution and the addition of an oxidant (i.e., ammonium persulfate) are crucial for microcapsule survival and the initiation of PDA polymerization, respectively. The resulting PDA coating is a dense and uniform layer approximately 50 nm thick. The PDA protective coating significantly increases capsule stability at an elevated temperature (180 °C) and in a variety of organic solvents and acidic/basic solutions that otherwise lead to deflation and loss of the core content of uncoated microcapsules.

  6. Superior Thermal Interface via Vertically Aligned Carbon Nanotubes Grown on Graphite Foils

    Science.gov (United States)

    2012-01-01

    L.L. Zhang, Z. Xiong, and X.S. Zhao: Pillaring chemically exfoliated graphene oxide with carbon nanotubes for photocatalytic degrada- tion of dyes...and V.T. Renard: Few graphene layers/carbon nanotube composites grown at complimentary-metal-oxide- semiconductor compatible temper- ature. Appl

  7. Excitation and ionization of hydrogen Rydberg states in a plasma.

    Science.gov (United States)

    Glab, W; Nayfeh, M H

    1982-08-01

    Hydrogen Rydberg states in a hydrogen plasma are optically excited from the plasma-excited n = 2 state. Photoionization and optogalvanic ionization, which is due to electron-impact ionization and other collisional processes, are used to monitor the Rydberg states. This process may be used to study collisional ionization of the Rydberg states.

  8. High order fluid model for ionization fronts in streamer discharges

    NARCIS (Netherlands)

    Markosyan, A.; Dujko, S.; Hundsdorfer, W.; Ebert, U.

    2011-01-01

    When non-ionized or lowly ionized matter is exposed to high electric fields, non-equilibrium ionization processes, streamer discharges, can develop. Streamers occur in nature and as well in many industrial applications such as the treatment of exhaust gasses, polluted water or biogas. A third order

  9. Long Duration Life Test of Propylene Glycol Water Based Thermal Fluid Within Thermal Control Loop

    Science.gov (United States)

    Le, Hung; Hill, Charles; Stephan, Ryan A.

    2010-01-01

    Evaluations of thermal properties and resistance to microbial growth concluded that 50% Propylene Glycol (PG)-based fluid and 50% de-ionized water mixture was desirable for use as a fluid within a vehicle s thermal control loop. However, previous testing with a commercial mixture of PG and water containing phosphate corrosion inhibitors resulted in corrosion of aluminum within the test system and instability of the test fluid. This paper describes a follow-on long duration testing and analysis of 50% Propylene Glycol (PG)-based fluid and 50% de-ionized water mixture with inorganic corrosion inhibitors used in place of phosphates. The test evaluates the long-term fluid stability and resistance to microbial and chemical changes

  10. A Low-Noise Germanium Ionization Spectrometer for Low-Background Science

    Energy Technology Data Exchange (ETDEWEB)

    Aalseth, Craig E.; Colaresi, Jim; Collar, Juan I.; Fast, James E.; Hossbach, Todd W.; Orrell, John L.; Overman, Cory T.; Scholz, Bjorn; Vandevender, Brent A.; Yocum, K. Michael

    2016-12-01

    Recent progress on the development of very low energy threshold high purity germanium ionization spectrometers has produced an instrument of 1.2 kg mass and excellent noise performance. The detector was installed in a low-background cryostat intended for use in a low mass, WIMP dark matter direct detection search. The integrated detector and low background cryostat achieved noise performance of 98 eV full-width half-maximum of an input electronic pulse generator peak and gamma-ray energy resolution of 1.9 keV full-width half-maximum at the 60Co gamma-ray energy of 1332 keV. This Transaction reports the thermal characterization of the low-background cryostat, specifications of the newly prepared 1.2 kg p-type point contact germanium detector, and the ionization spectroscopy – energy resolution and energy threshold – performance of the integrated system.

  11. Modulation of waves due to charge-exchange collisions in magnetized partially ionized space plasma

    Energy Technology Data Exchange (ETDEWEB)

    Shaikh, Dastgeer, E-mail: dastgeer.shaikh@uah.ed [Department of Physics and Center for Space Plasma and Aeronomy Research, University of Alabama in Huntsville, Huntsville, AL 35899 (United States); Zank, G.P. [Department of Physics and Center for Space Plasma and Aeronomy Research, University of Alabama in Huntsville, Huntsville, AL 35899 (United States)

    2010-10-04

    A nonlinear time dependent fluid simulation model is developed that describes the evolution of magnetohydrodynamic waves in the presence of collisional and charge exchange interactions of a partially ionized plasma. The partially ionized plasma consists of electrons, ions and a significant number of neutral atoms. In our model, the electrons and ions are described by a single fluid compressible magnetohydrodynamic (MHD) model and are coupled self-consistently to the neutral gas, described by the compressible hydrodynamic equations. Both the plasma and neutral fluids are treated with different energy equations that describe thermal energy exchange processes between them. Based on our self-consistent model, we find that propagating Alfvenic and fast/slow modes grow and damp alternately through a nonlinear modulation process. The modulation appears to be robust and survives strong damping by the neutral component.

  12. Modulation of waves due to charge-exchange collisions in magnetized partially ionized space plasma

    CERN Document Server

    Shaikh, Dastgeer

    2010-01-01

    A nonlinear time dependent fluid simulation model is developed that describes the evolution of magnetohydrodynamic waves in the presence of collisional and charge exchange interactions of a partially ionized plasma. The partially ionized plasma consists of electrons, ions and a significant number of neutral atoms. In our model, the electrons and ions are described by a single fluid compressible magnetohydrodynamic (MHD) model and are coupled self-consistently to the neutral gas, described by the compressible hydrodynamic equations. Both the plasma and neutral fluids are treated with different energy equations that describe thermal energy exchange processes between them. Based on our self-consistent model, we find that propagating Alfv\\'enic and fast/slow modes grow and damp alternately through a nonlinear modulation process. The modulation appears to be robust and survives strong damping by the neutral component.

  13. Food quality and authenticity screening via easy ambient sonic-spray ionization mass spectrometry.

    Science.gov (United States)

    Porcari, Andreia M; Fernandes, Gabriel D; Barrera-Arellano, Daniel; Eberlin, Marcos N; Alberici, Rosana M

    2016-02-21

    This review is the first to summarize a decade of studies testing the use of easy ambient sonic-spray ionization mass spectrometry (EASI-MS) and its several sister techniques, Venturi (V-EASI), thermal imprinting (TI-EASI) and Spartan (S-EASI) mass spectrometry in food quality control and authentication. Since minimal or no sample preparation is required, such ambient desorption/ionization techniques have been shown to provide direct, fast and selective fingerprinting characterization at the molecular level based on the pools of the most typical components. They have also been found to be applicable on intact, undisturbed samples or on simple solvent extracts. Fundamentals of EASI-MS and its sister techniques, including mechanisms, devices, parameters and strategies, as well as the many applications reported for food analysis, are summarized and discussed.

  14. Applications of electrospray laser desorption ionization mass spectrometry for document examination.

    Science.gov (United States)

    Cheng, Sy-Chyi; Lin, Yu-Shan; Huang, Ming-Zong; Shiea, Jentaie

    2010-01-01

    We have employed electrospray laser desorption ionization mass spectrometry (ELDI-MS) to rapidly characterize certain classes of compounds--the inks within the characters made by inks and inkjet printer on regular paper and the chemical compounds within thermal papers. This ELDI-MS approach allowed the ink and paper samples to be distinguished in terms of their chemical compositions. Sample pretreatment was unnecessary and the documents were practically undamaged after examination. The ink chemicals on the documents were desorbed through laser irradiation (sampling spot area: <100 microm(2)); the desorbed molecules then entered an electrospray plume--prepared from an acidic methanol/water solution (50%)--where they became ionized through fusion or ion-molecule reactions with the charged solvent species and droplets in the plume.

  15. Ionization history of the Universe as a test for Super Heavy Dark Matter particles

    CERN Document Server

    Doroshkevich, A G

    2002-01-01

    In this paper we discuss the possible distortions of the ionization history of the universe caused by an injection of non-thermal energy due to decays of hypothetical Super Heavy Dark Matter (SHDM) particles. These particles are usually considered as a possible source of Ultra High Energy Cosmic Rays (UHECRs) in the framework of the Top-Down model. Estimates of fraction of energy of decays converted to the UV range show that, for suitable parameters of SHDM particles, the significant distortions of power spectra of CMB anisotropy appear. Comparison with the observed power spectrum allows to restrict some properties of the SHDM particles. These decays can also increase of about 5 -- 10 times the degree of ionization of hydrogen at redshifts $z\\sim$ 10 -- 50 that essentially accelerates the formation of molecules $H_2$ and first stars during "dark ages".

  16. Electrospray Ionization Mass Spectrometry: A Technique to Access the Information beyond the Molecular Weight of the Analyte

    Directory of Open Access Journals (Sweden)

    Shibdas Banerjee

    2012-01-01

    Full Text Available The Electrospray Ionization (ESI is a soft ionization technique extensively used for production of gas phase ions (without fragmentation of thermally labile large supramolecules. In the present review we have described the development of Electrospray Ionization mass spectrometry (ESI-MS during the last 25 years in the study of various properties of different types of biological molecules. There have been extensive studies on the mechanism of formation of charged gaseous species by the ESI. Several groups have investigated the origin and implications of the multiple charge states of proteins observed in the ESI-mass spectra of the proteins. The charged analytes produced by ESI can be fragmented by activating them in the gas-phase, and thus tandem mass spectrometry has been developed, which provides very important insights on the structural properties of the molecule. The review will highlight recent developments and emerging directions in this fascinating area of research.

  17. Thermal Conductivity of Diamond Composites

    Directory of Open Access Journals (Sweden)

    Fedor M. Shakhov

    2009-12-01

    Full Text Available A major problem challenging specialists in present-day materials sciences is the development of compact, cheap to fabricate heat sinks for electronic devices, primarily for computer processors, semiconductor lasers, high-power microchips, and electronics components. The materials currently used for heat sinks of such devices are aluminum and copper, with thermal conductivities of about 250 W/(m·K and 400 W/(m·K, respectively. Significantly, the thermal expansion coefficient of metals differs markedly from those of the materials employed in semiconductor electronics (mostly silicon; one should add here the low electrical resistivity metals possess. By contrast, natural single-crystal diamond is known to feature the highest thermal conductivity of all the bulk materials studied thus far, as high as 2,200 W/(m·K. Needless to say, it cannot be applied in heat removal technology because of high cost. Recently, SiC- and AlN-based ceramics have started enjoying wide use as heat sink materials; the thermal conductivity of such composites, however, is inferior to that of metals by nearly a factor two. This prompts a challenging scientific problem to develop diamond-based composites with thermal characteristics superior to those of aluminum and copper, adjustable thermal expansion coefficient, low electrical conductivity and a moderate cost, below that of the natural single-crystal diamond. The present review addresses this problem and appraises the results reached by now in studying the possibility of developing composites in diamond-containing systems with a view of obtaining materials with a high thermal conductivity.

  18. Thermal and Non-thermal X-Rays from the LMC Super Bubble 30 Dor C

    CERN Document Server

    Bamba, A; Nakajima, H; Koyama, K; Bamba, Aya; Ueno, Masaru; Nakajima, Hiroshi; Koyama, Katsuji

    2004-01-01

    We report on the discovery of thermal and non-thermal X-rays from the shells of the super bubble (SB) 30 Dor C in the Large Magellanic Cloud (LMC). The X-ray morphology is a nearly circular shell with a radius of about 40 pc, which is bright on the northern and western sides. The spectra of the shells are different from region to region. The southern shell shows clear emission lines, and is well fitted with a model of a thin-thermal plasma (kT = 0.21keV) in non-equilibrium ionization (NEI) plus a power-law component. This thermal plasma is located inside of the H alpha emission, which is the outer edge of the shell of the SB. The northern and western sides of the SB are dim in H alpha emission, but are bright in non-thermal (power-law) X-rays with a photon index of 2.1-2.9. The non-thermal X-ray shell traces the outer boundary of the radio shell. These features of thin-thermal and non-thermal X-rays are similar to those of SN 1006, a prototype of synchrotron X-ray shell, but the non-thermal component of 30 Do...

  19. Pratt & Whitney thermal barrier coatings

    Energy Technology Data Exchange (ETDEWEB)

    Bornstein, N. [United Technologies Research Center, East Hartford, CT (United States); Marcin, J. [Pratt & Whitney Aircraft Co., East Hartford, CT (United States)

    1995-10-01

    The objective of the Advanced Turbine Systems (ATS) Program is to develop ultra-high efficient, environmentally superior, and cost competitive gas turbine systems. The operating profiles of these industrial gas turbines are long, less cyclic with fewer transients-compared with those for aircraft gas turbine engines. Therefore, creep rather than thermal fatigue, becomes primary life-limiting for hot section components. Thermal barrier coatings (TBCs) will be used to achieve the objectives of the program. TBCs allow surface temperatures to increase without compromising the structural properties of the alloy. TBCs typically consist of a ceramic insulating layer, deposited onto the substrate with an intervening metallic layer, which imparts oxidation protection to the substrate and provides a surface to which the ceramic layer can adhere.

  20. Acquired Brown Syndrome Treated With Traction of Superior Oblique Tendon.

    Science.gov (United States)

    Shin, Kwang Hoon; Paik, Hae Jung; Chi, Mijung

    2016-03-01

    Brown syndrome is a rare strabismic disease characterized by a limited elevation in adduction of the eye. The lengthening/weakening of superior oblique muscle is the main way of surgical intervention for this disease. A 7-year-old boy was diagnosed as having acquired Brown syndrome in his right eye after injury in his face. We experienced successful release of this Brown syndrome through mere pulling outward of superior oblique tendon during surgical exploration. We briefly discuss why this manipulation of superior oblique tendon that we performed was successful.

  1. Right superior vena cava draining into the left atrium

    Energy Technology Data Exchange (ETDEWEB)

    Calcagni, Giulio; Sidi, Daniel; Bonnet, Damien [University Rene Descartes-Paris 5, Department of Paediatric Cardiology, Hopital Necker-Enfants Malades, Paris (France); Batisse, Alain [Institut de Puericulture et de Perinatalogie, Paris (France); Vouhe, Pascal [University Rene Descartes-Paris 5, Department of Paediatric Cardiac Surgery, Hopital Necker-Enfants Malades, Paris (France); Ou, Phalla [University Rene Descartes-Paris 5, Department of Paediatric Cardiology, Hopital Necker-Enfants Malades, Paris (France); University Rene Descartes-Paris 5, Department of Pediatric Radiology, Hopital Necker-Enfants Malades, Paris (France)

    2008-08-15

    The right superior vena cava draining into the left atrium is a rare malformation causing cyanosis and clubbing in patients in whom no other signs of congenital heart defect are present. Diagnosis may be difficult as cyanosis may be mild and the anomaly is not always easily detectable by echocardiography. For this reason we report a 13-month-old male in whom we confirmed the clinical and echocardiographic suspicion of anomalous drainage of the right superior vena cava using multidetector CT. This allowed successful surgical reconnection of the right superior vena cava to the right atrium. (orig.)

  2. Noise management to achieve superiority in quantum information systems

    Science.gov (United States)

    Nemoto, Kae; Devitt, Simon; Munro, William J.

    2017-06-01

    Quantum information systems are expected to exhibit superiority compared with their classical counterparts. This superiority arises from the quantum coherences present in these quantum systems, which are obviously absent in classical ones. To exploit such quantum coherences, it is essential to control the phase information in the quantum state. The phase is analogue in nature, rather than binary. This makes quantum information technology fundamentally different from our classical digital information technology. In this paper, we analyse error sources and illustrate how these errors must be managed for the system to achieve the required fidelity and a quantum superiority. This article is part of the themed issue 'Quantum technology for the 21st century'.

  3. Thermal Hardware for the Thermal Analyst

    Science.gov (United States)

    Steinfeld, David

    2015-01-01

    The presentation will be given at the 26th Annual Thermal Fluids Analysis Workshop (TFAWS 2015) hosted by the Goddard Space Flight Center (GSFC) Thermal Engineering Branch (Code 545). NCTS 21070-1. Most Thermal analysts do not have a good background into the hardware which thermally controls the spacecraft they design. SINDA and Thermal Desktop models are nice, but knowing how this applies to the actual thermal hardware (heaters, thermostats, thermistors, MLI blanketing, optical coatings, etc...) is just as important. The course will delve into the thermal hardware and their application techniques on actual spacecraft. Knowledge of how thermal hardware is used and applied will make a thermal analyst a better engineer.

  4. Determination of triacetone triperoxide using ultraviolet femtosecond multiphoton ionization time-of-flight mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ezoe, Ryota [Department of Applied Chemistry, Graduate School of Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395 (Japan); Imasaka, Tomoko [Laboratory of Chemistry, Graduate School of Design, Kyushu University, 4-9-1, Shiobaru, Minami-ku, Fukuoka 815-8540 (Japan); Imasaka, Totaro, E-mail: imasaka@cstf.kyushu-u.ac.jp [Department of Applied Chemistry, Graduate School of Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395 (Japan); Division of Optoelectronics and Photonics, Center for Future Chemistry, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395 (Japan)

    2015-01-01

    Highlights: • A UV ultrashort laser pulse was useful for ionization of triacetone triperoxide. • A molecular ion was strongly enhanced in multiphoton ionization mass spectrometry. • Triacetone triperoxide in the human blood was measured without any interferences. • An organic compound of phorone was formed in the human blood from acetone. - Abstract: Triacetone triperoxide (TATP), an explosive compound, was measured using gas chromatography combined with multiphoton ionization time-of-flight mass spectrometry (GC/MPI-TOFMS). By decreasing the pulse width of a femtosecond laser from 80 to 35 fs, a molecular ion was drastically enhanced and was measured as one of the major ions in the mass spectrum. The detection limits obtained using the molecular (M·{sup +}) and fragment (C{sub 2}H{sub 3}O{sup +}) ions were similar or slightly superior to those obtained using conventional mass spectrometry based on electron and chemical ionization. In order to improve the reliability, an isotope of TATP, i.e., TATP-d18, was synthesized and used as an internal standard in the trace analysis of TATP in a sample of human blood. TATP could be identified in a two-dimensional display, even though numerous interfering compounds were present in the sample. Acetone, which is frequently used as a solvent in sampling TATP, produced a chemical species with a retention time nearly identical to that of TATP and provided a C{sub 2}H{sub 3}O{sup +} fragment ion that was employed for measuring a chromatogram of TATP in conventional MS. This compound, the structure of which was assigned as phorone, was clearly differentiated from TATP based on a molecular ion observable in MPI-TOFMS.

  5. Ambient Mass Spectrometry Imaging with Picosecond Infrared Laser Ablation Electrospray Ionization (PIR-LAESI).

    Science.gov (United States)

    Zou, Jing; Talbot, Francis; Tata, Alessandra; Ermini, Leonardo; Franjic, Kresimir; Ventura, Manuela; Zheng, Jinzi; Ginsberg, Howard; Post, Martin; Ifa, Demian R; Jaffray, David; Miller, R J Dwayne; Zarrine-Afsar, Arash

    2015-12-15

    A picosecond infrared laser (PIRL) is capable of cutting through biological tissues in the absence of significant thermal damage. As such, PIRL is a standalone surgical scalpel with the added bonus of minimal postoperative scar tissue formation. In this work, a tandem of PIRL ablation with electrospray ionization (PIR-LAESI) mass spectrometry is demonstrated and characterized for tissue molecular imaging, with a limit of detection in the range of 100 nM for reserpine or better than 5 nM for verapamil in aqueous solution. We characterized PIRL crater size using agar films containing Rhodamine. PIR-LAESI offers a 20-30 μm vertical resolution (∼3 μm removal per pulse) and a lateral resolution of ∼100 μm. We were able to detect 25 fmol of Rhodamine in agar ablation experiments. PIR-LAESI was used to map the distribution of endogenous methoxykaempferol glucoronide in zebra plant (Aphelandra squarrosa) leaves producing a localization map that is corroborated by the literature. PIR-LAESI was further used to image the distribution inside mouse kidneys of gadoteridol, an exogenous magnetic resonance contrast agent intravenously injected. Parallel mass spectrometry imaging (MSI) using desorption electrospray ionization (DESI) and matrix assisted laser desorption ionization (MALDI) were performed to corroborate PIR-LAESI images of the exogenous agent. We further show that PIR-LAESI is capable of desorption ionization of proteins as well as phospholipids. This comparative study illustrates that PIR-LAESI is an ion source for ambient mass spectrometry applications. As such, a future PIRL scalpel combined with secondary ionization such as ESI and mass spectrometry has the potential to provide molecular feedback to guide PIRL surgery.

  6. Tunnel ionization, population trapping, filamentation and applications

    Science.gov (United States)

    Leang Chin, See; Xu, Huailiang

    2016-11-01

    The advances in femtosecond Ti-sapphire laser technology have led to the discovery of a profusion of new physics. This review starts with a brief historical account of the experimental realization of tunnel ionization, followed by high harmonic generation and the prediction of attosecond pulses. Then, the unique phenomenon of dynamic population trapping during the ionization of atoms and molecules in intense laser fields is introduced. One of the consequences of population trapping in the highly excited states is the neutral dissociation into simple molecular fragments which fluoresce. Such fluorescence could be amplified in femtosecond laser filamentation in gases. The experimental observations of filament-induced fluorescence and lasing in the atmosphere and combustion flames are given. Excitation of molecular rotational wave packets (molecular alignment) and their relaxation and revival in a gas filament are described. Furthermore, filament-induced condensation and precipitation inside a cloud chamber is explained. Lastly, a summary and future outlook is given.

  7. Communication: Electron ionization of DNA bases

    Science.gov (United States)

    Rahman, M. A.; Krishnakumar, E.

    2016-04-01

    No reliable experimental data exist for the partial and total electron ionization cross sections for DNA bases, which are very crucial for modeling radiation damage in genetic material of living cell. We have measured a complete set of absolute partial electron ionization cross sections up to 500 eV for DNA bases for the first time by using the relative flow technique. These partial cross sections are summed to obtain total ion cross sections for all the four bases and are compared with the existing theoretical calculations and the only set of measured absolute cross sections. Our measurements clearly resolve the existing discrepancy between the theoretical and experimental results, thereby providing for the first time reliable numbers for partial and total ion cross sections for these molecules. The results on fragmentation analysis of adenine supports the theory of its formation in space.

  8. Atmospheric Ionizing Radiation and Human Exposure

    Science.gov (United States)

    Wilson, John W.; Mertens, Christopher J.; Goldhagen, Paul; Friedberg, W.; DeAngelis, G.; Clem, J. M.; Copeland, K.; Bidasaria, H. B.

    2005-01-01

    Atmospheric ionizing radiation is of interest, apart from its main concern of aircraft exposures, because it is a principal source of human exposure to radiations with high linear energy transfer (LET). The ionizing radiations of the lower atmosphere near the Earth s surface tend to be dominated by the terrestrial radioisotopes. especially along the coastal plain and interior low lands, and have only minor contributions from neutrons (11 percent). The world average is substantially larger but the high altitude cities especially have substantial contributions from neutrons (25 to 45 percent). Understanding the world distribution of neutron exposures requires an improved understanding of the latitudinal, longitudinal, altitude and spectral distribution that depends on local terrain and time. These issues are being investigated in a combined experimental and theoretical program. This paper will give an overview of human exposures and describe the development of improved environmental models.

  9. Upper Hybrid Effects in Artificial Ionization

    Science.gov (United States)

    Papadopoulos, K.; Eliasson, B. E.

    2014-12-01

    A most fascinating result of recent ionospheric experiments has been the discovery of artificial ionization by Pedersen et al. (GRL, 37, L02106, 2010). The Artificial Ionospheric Layers (AIL) were the result of F-region O-mode HF irradiation using the HAARP ionospheric heater operating at 3.6 MW power. As demonstrated by Eliasson et al. (JGR, 117, A10321, 2012) the physics controlling the observed phenomenon and its threshold can be summarized as: " Collisional ionization due to high energy (~ 20 eV) electron tails generated by the interaction of strong Langmuir turbulence with plasma heated at the upper hybrid resonance and transported at the reflection height". The objective of the current presentation is to explore the role of the upper hybrid heating in the formation of AIL and its implications to future experiments involving HF heaters operating in middle and equatorial latitudes.

  10. External ionization mechanisms for advanced thermionic converters

    Science.gov (United States)

    Hatziprokopiou, M. E.

    Ion generation and recombination mechanisms in the cesium plasma were investigated as they pertain to the advanced mode thermionic energy converters. The changes in plasma density and temperature within the converter were studied under the influence of several promising auxiliary ionization candidate sources. Three novel approaches of external cesium ion generation were investigated in some detail, namely vibrationally excited N2 as an energy source of ionization of Cs ions in a DC discharge, microwave power as a means of resonant sustenance of the cesium plasma, and ion generation in a pulse N2-Cs mixture. The experimental data obtained and discussed in this work show that all three techniques--i.e. the non-LTE high-voltage pulsing, the energy transfer from vibrationally excited diatomic gases, and the external pumping with a microwave power--have considerable promise as schemes in auxiliary ion generation applicable to the advanced thermionic energy converter.

  11. Electrospray Ionization Mass Spectra of Dipeptide Derivatives

    Institute of Scientific and Technical Information of China (English)

    LUO, Zaigang; ZENG, Chengchu; YANG, Daoshan; HUANG, Yali; WANG, Fang; DU, Hongguang; HU, Liming

    2009-01-01

    Based on the structure of the HIV integrase core domain, dipeptide derivatives, as a type of HIV integrase in- hibitor, were synthesized, and their fragmentation pathways were investigated by electrospray ionization mass spec- trometry (ESI-MSN) in conjunction with tandem mass spectrometry (MS/MS). In order to better understand the fragmentation pathways, the MS2 and MS3 spectra of the title compound were obtained. The main fragmentation pathways occur by the cleavage of the C-CO bonds between N-(benzothiazol-2-yl)aminocarbonyl and methylene, NH-CO bonds between the NH groups and carbonyl groups. Electrospray ionization was proven to be a good method for the structural characterization and identification of this kind of compound.

  12. Ionization and Dust Charging in Protoplanetary Disks

    CERN Document Server

    Ivlev, A V; Caselli, P

    2016-01-01

    Ionization-recombination balance in dense interstellar and circumstellar environments is a key factor for a variety of important physical processes, such as chemical reactions, dust charging and coagulation, coupling of the gas with magnetic field and the development of magnetorotational instability in protoplanetary disks. We present a self-consistent analytical model which allows us to exactly calculate abundances of charged species in dusty gas, in the regime where the dust-phase recombination dominates over the gas-phase recombination. The model is employed to verify applicability of a conventional approximation of low dust charges in protoplanetary disks, and to discuss the implications for the dust coagulation and the development of the "dead zone" in the disk. Furthermore, the importance of mutually consistent models for the ionization and dust evolution is addressed: These processes are coupled via several mechanisms operating in the disk, and therefore their interplay can be crucial for the ultimate ...

  13. Kolmogorov Dissipation scales in Weakly Ionized Plasmas

    CERN Document Server

    Krishan, V

    2009-01-01

    In a weakly ionized plasma, the evolution of the magnetic field is described by a "generalized Ohm's law" that includes the Hall effect and the ambipolar diffusion terms. These terms introduce additional spatial and time scales which play a decisive role in the cascading and the dissipation mechanisms in magnetohydrodynamic turbulence. We determine the Kolmogorov dissipation scales for the viscous, the resistive and the ambipolar dissipation mechanisms. The plasma, depending on its properties and the energy injection rate, may preferentially select one of the these dissipation scales. thus determining the shortest spatial scale of the supposedly self-similar spectral distribution of the magnetic field. The results are illustrated taking the partially ionized part of the solar atmosphere as an example. Thus the shortest spatial scale of the supposedly self-similar spectral distribution of the solar magnetic field is determined by any of the four dissipation scales given by the viscosity, the Spizer resistivity...

  14. New constraints on the escape of ionizing photons from starburst galaxies using ionization-parameter mapping

    Energy Technology Data Exchange (ETDEWEB)

    Zastrow, Jordan; Oey, M. S. [Department of Astronomy, University of Michigan, 500 Church Street, 830 Dennison, Ann Arbor, MI 48109-1042 (United States); Veilleux, Sylvain [Department of Astronomy, University of Maryland, College Park, MD 20742 (United States); McDonald, Michael, E-mail: jazast@umich.edu [Kavli Institute for Astrophysics and Space Research, MIT, Cambridge, MA 02139 (United States)

    2013-12-10

    The fate of ionizing radiation in starburst galaxies is key to understanding cosmic reionization. However, the galactic parameters on which the escape fraction of ionizing radiation depend are not well understood. Ionization-parameter mapping provides a simple, yet effective, way to study the radiative transfer in starburst galaxies. We obtain emission-line ratio maps of [S III]/[S II] for six, nearby, dwarf starbursts: NGC 178, NGC 1482, NGC 1705, NGC 3125, NGC 7126, and He 2-10. The narrowband images are obtained with the Maryland-Magellan Tunable Filter at Las Campanas Observatory. Using these data, we previously reported the discovery of an optically thin ionization cone in NGC 5253, and here we also discover a similar ionization cone in NGC 3125. This latter cone has an opening angle of 40° ± 5° (0.4 sr), indicating that the passageways through which ionizing radiation may travel correspond to a small solid angle. Additionally, there are three sample galaxies that have winds and/or superbubble activity, which should be conducive to escaping radiation, yet they are optically thick. These results support the scenario that an orientation bias limits our ability to directly detect escaping Lyman continuum in many starburst galaxies. A comparison of the star formation properties and histories of the optically thin and thick galaxies is consistent with the model that high escape fractions are limited to galaxies that are old enough (≳3 Myr) for mechanical feedback to have cleared optically thin passageways in the interstellar medium, but young enough (≲5 Myr) that the ionizing stars are still present.

  15. New Constraints on the Escape of Ionizing Photons from Starburst Galaxies Using Ionization-parameter Mapping

    Science.gov (United States)

    Zastrow, Jordan; Oey, M. S.; Veilleux, Sylvain; McDonald, Michael

    2013-12-01

    The fate of ionizing radiation in starburst galaxies is key to understanding cosmic reionization. However, the galactic parameters on which the escape fraction of ionizing radiation depend are not well understood. Ionization-parameter mapping provides a simple, yet effective, way to study the radiative transfer in starburst galaxies. We obtain emission-line ratio maps of [S III]/[S II] for six, nearby, dwarf starbursts: NGC 178, NGC 1482, NGC 1705, NGC 3125, NGC 7126, and He 2-10. The narrowband images are obtained with the Maryland-Magellan Tunable Filter at Las Campanas Observatory. Using these data, we previously reported the discovery of an optically thin ionization cone in NGC 5253, and here we also discover a similar ionization cone in NGC 3125. This latter cone has an opening angle of 40° ± 5° (0.4 sr), indicating that the passageways through which ionizing radiation may travel correspond to a small solid angle. Additionally, there are three sample galaxies that have winds and/or superbubble activity, which should be conducive to escaping radiation, yet they are optically thick. These results support the scenario that an orientation bias limits our ability to directly detect escaping Lyman continuum in many starburst galaxies. A comparison of the star formation properties and histories of the optically thin and thick galaxies is consistent with the model that high escape fractions are limited to galaxies that are old enough (gsim3 Myr) for mechanical feedback to have cleared optically thin passageways in the interstellar medium, but young enough (lsim5 Myr) that the ionizing stars are still present.

  16. Ionization photophysics and spectroscopy of cyanoacetylene

    Energy Technology Data Exchange (ETDEWEB)

    Leach, Sydney; Champion, Norbert [LERMA UMR CNRS 8112, Observatoire de Paris-Meudon, 5 place Jules-Jansen, 92195 Meudon (France); Garcia, Gustavo A.; Fray, Nicolas; Gaie-Levrel, François [Synchrotron SOLEIL, L’Orme des Merisiers, St. Aubin, B.P. 48, 91192, Gif-sur-Yvette Cedex (France); Mahjoub, Ahmed; Bénilan, Yves; Gazeau, Marie-Claire; Schwell, Martin [LISA UMR CNRS 7583, Université Paris Est Créteil and Université Paris Diderot, Institut Pierre Simon Laplace, 61 Avenue du Général de Gaulle, 94010 Créteil (France)

    2014-05-07

    Photoionization of cyanoacetylene was studied using synchrotron radiation over the non-dissociative ionization excitation range 11–15.6 eV, with photoelectron-photoion coincidence techniques. The absolute ionization cross-section and spectroscopic aspects of the parent ion were recorded. The adiabatic ionization energy of cyanoacetylene was measured as 11.573 ± 0.010 eV. A detailed analysis of photoelectron spectra of HC{sub 3}N involves new aspects and new assignments of the vibrational components to excitation of the A{sup 2}Σ{sup +} and B{sup 2}Π states of the cation. Some of the structured autoionization features observed in the 11.94 to 15.5 eV region of the total ion yield (TIY) spectrum were assigned to two Rydberg series converging to the B{sup 2}Π state of HC{sub 3}N{sup +}. A number of the measured TIY features are suggested to be vibrational components of Rydberg series converging to the C{sup 2}Σ{sup +} state of HC{sub 3}N{sup +} at ≈17.6 eV and others to valence shell transitions of cyanoacetylene in the 11.6–15 eV region. The results of quantum chemical calculations of the cation electronic state geometries, vibrational frequencies and energies, as well as of the C–H dissociation potential energy profiles of the ground and electronic excited states of the ion, are compared with experimental observations. Ionization quantum yields are evaluated and discussed and the problem of adequate calibration of photoionization cross-sections is raised.

  17. Improvement of a New Gas Ionization Chamber

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    In order to identify heavier elements, we have developed a new longitudinal field gas ionization chamber (IC)with an angle of 30° of plate (as shown in Fig.1). The IC is operated in flowing iso-butane gas at a pressure of 10kPa. After testing by using a 3- component α particle source and comparing with the old longitudinal field

  18. LET measurements with a Liquid Ionization Chamber

    OpenAIRE

    Tegami, S.

    2013-01-01

    Deep-seated tumors can be efficiently treated with heavy charged particles. The characteristic depth dose profile inside the tissue (Bragg peak) allows to deliver a high dose inside the tumor, while sparing the neighboring healthy tissue. As compared to protons, heavy ions like carbon or oxygen produce a higher amount of ionization events along their track (and in particular at the end of the ion beam path), resulting in an irreparable damage to the DNA of the tumor cells. T...

  19. Recollision induced superradiance of ionized nitrogen molecules

    CERN Document Server

    Liu, Yi; Lambert, Guillaume; Houard, Aurelien; Tikhonchuk, Vladimir; Mysyrowicz, Andre

    2015-01-01

    We propose a new mechanism to explain the origin of optical gain in the transitions between excited and ground state of the ionized nitrogen molecule following irradiation of neutral nitrogen molecules with an intense ultra short laser pulse. An efficient transfer of population to the excited state is achieved via field-induced multiple recollisions. We show that the proposed excitation mechanism must lead to a super-radiant emission, a feature that we confirm experimentally.

  20. Secondary ionization in a flat universe

    Science.gov (United States)

    Atrio-Barandela, F.; Doroshkevich, A. G.

    1994-01-01

    We analyze the effect of a secondary ionization on the evolution of temperature fluctuations in cosmic background radiation. The main results presented in this paper are appropriate analytic expressions of the transfer function relating temperature fluctuations to matter density perturbations at recombination for all possible recombination histories. Furthermore, we particularize our calculation to the standard cold dark matter model, where we study the erasure of primordial temperature fluctuations and calculate the magnitude and angular scale of the damping induced by a late recombination.

  1. Alloy nanoparticle synthesis using ionizing radiation

    Science.gov (United States)

    Nenoff, Tina M.; Powers, Dana A.; Zhang, Zhenyuan

    2011-08-16

    A method of forming stable nanoparticles comprising substantially uniform alloys of metals. A high dose of ionizing radiation is used to generate high concentrations of solvated electrons and optionally radical reducing species that rapidly reduce a mixture of metal ion source species to form alloy nanoparticles. The method can make uniform alloy nanoparticles from normally immiscible metals by overcoming the thermodynamic limitations that would preferentially produce core-shell nanoparticles.

  2. Ionizing laser propagation and spectral phase determination

    Science.gov (United States)

    Mittelberger, D. E.; Nakamura, K.; Lehe, R.; Gonsalves, A. J.; Benedetti, C.; Mao, H.-S.; Daniels, J.; Dale, N.; Swanson, K. K.; Esarey, E.; Leemans, W. P.

    2017-03-01

    Ionization-induced blueshifting is investigated through INF&RNO simulations and experimental studies at the Berkeley Laboratory Laser Accelerator (BELLA) Center. The effects of spectral phase and optical compression are explored. An in-situ method for verifying the spectral phase of an intense laser pulse at focus is presented, based on the effects of optical compression on the morphology of the blueshifted laser spectra.

  3. Making MUSIC: A multiple sampling ionization chamber

    Energy Technology Data Exchange (ETDEWEB)

    Shumard, B. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States)]. E-mail: shumard@phy.anl.gov; Henderson, D.J. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States); Rehm, K.E. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States); Tang, X.D. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States)

    2007-08-15

    A multiple sampling ionization chamber (MUSIC) was developed for use in conjunction with the Atlas scattering chamber (ATSCAT). This chamber was developed to study the ({alpha}, p) reaction in stable and radioactive beams. The gas filled ionization chamber is used as a target and detector for both particles in the outgoing channel (p + beam particles for elastic scattering or p + residual nucleus for ({alpha}, p) reactions). The MUSIC detector is followed by a Si array to provide a trigger for anode events. The anode events are gated by a gating grid so that only ({alpha}, p) reactions where the proton reaches the Si detector result in an anode event. The MUSIC detector is a segmented ionization chamber. The active length of the chamber is 11.95 in. and is divided into 16 equal anode segments (3.5 in. x 0.70 in. with 0.3 in. spacing between pads). The dead area of the chamber was reduced by the addition of a Delrin snout that extends 0.875 in. into the chamber from the front face, to which a mylar window is affixed. 0.5 in. above the anode is a Frisch grid that is held at ground potential. 0.5 in. above the Frisch grid is a gating grid. The gating grid functions as a drift electron barrier, effectively halting the gathering of signals. Setting two sets of alternating wires at differing potentials creates a lateral electric field which traps the drift electrons, stopping the collection of anode signals. The chamber also has a reinforced mylar exit window separating the Si array from the target gas. This allows protons from the ({alpha}, p) reaction to be detected. The detection of these protons opens the gating grid to allow the drift electrons released from the ionizing gas during the ({alpha}, p) reaction to reach the anode segment below the reaction.

  4. Ionization photophysics and spectroscopy of cyanoacetylene

    Science.gov (United States)

    Leach, Sydney; Garcia, Gustavo A.; Mahjoub, Ahmed; Bénilan, Yves; Fray, Nicolas; Gazeau, Marie-Claire; Gaie-Levrel, François; Champion, Norbert; Schwell, Martin

    2014-05-01

    Photoionization of cyanoacetylene was studied using synchrotron radiation over the non-dissociative ionization excitation range 11-15.6 eV, with photoelectron-photoion coincidence techniques. The absolute ionization cross-section and spectroscopic aspects of the parent ion were recorded. The adiabatic ionization energy of cyanoacetylene was measured as 11.573 ± 0.010 eV. A detailed analysis of photoelectron spectra of HC3N involves new aspects and new assignments of the vibrational components to excitation of the A2Σ+ and B2Π states of the cation. Some of the structured autoionization features observed in the 11.94 to 15.5 eV region of the total ion yield (TIY) spectrum were assigned to two Rydberg series converging to the B2Π state of HC3N+. A number of the measured TIY features are suggested to be vibrational components of Rydberg series converging to the C2Σ+ state of HC3N+ at ≈17.6 eV and others to valence shell transitions of cyanoacetylene in the 11.6-15 eV region. The results of quantum chemical calculations of the cation electronic state geometries, vibrational frequencies and energies, as well as of the C-H dissociation potential energy profiles of the ground and electronic excited states of the ion, are compared with experimental observations. Ionization quantum yields are evaluated and discussed and the problem of adequate calibration of photoionization cross-sections is raised.

  5. Comparative study of the use of non-ionizing and ionizing radiation in the cure of epoxy resin: microwave versus electron electron

    Energy Technology Data Exchange (ETDEWEB)

    Kersting, Daniel, E-mail: daniel.kersting@usp.br [Centro Tecnologico da Marinha em Sao Paulo (CTMSP/USP), Sao Paulo, SP (Brazil); Wiebeck, Helio, E-mail: hwiebeck@usp.br [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Escola Politecnica. Dept. de Engenharia Metalurgica; Marinucci, Gerson; Silva, Leonardo G.A. e, E-mail: marinuci@ipen.br, E-mail: gasilva@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    Several processes for curing epoxy resins were developed over the years. Two methods are discussed in this paper, in order to present the main advantages and disadvantages of using microwave radiation (non-ionizing radiation) and electron beam radiation (ionizing radiation). The microwave radiation is a non-ionizing radiation, with great power of penetration and transfer of heat in microwave absorbing materials, or materials with microwave absorbing fillers. The frequency usually used in research and development is 2.45 GHz, the same available in commercial equipment. The microwave effect provides increase on the collision velocity between the reactant which, combined with energy absorbed by the reaction system, accelerates the curing reaction. None modifications in the epoxy system are required to use microwave heating for the curing process.On the other hand, the electron beam is a form of ionizing radiation in which the high energy electrons have the ability to interact with the irradiated material and produce ions, free radicals, and molecules in excited state, which can be used to initiate and propagate a polymerization. Specific initiators are necessary for an effective cure of the resin. In this study, a DGEBA epoxy resin with initiators based on anhydride and amine was used under the same conditions indicated by the manufacturer. The curing of the catalyzed system was performed in a domestic microwave oven adapted for laboratory use. The degradation and glass transition temperatures were evaluated by thermal analysis techniques. For comparative purposes, it was used data available in the literature for electron beam irradiation. (author)

  6. Ionizing radiation induces stemness in cancer cells.

    Directory of Open Access Journals (Sweden)

    Laura Ghisolfi

    Full Text Available The cancer stem cell (CSC model posits the presence of a small number of CSCs in the heterogeneous cancer cell population that are ultimately responsible for tumor initiation, as well as cancer recurrence and metastasis. CSCs have been isolated from a variety of human cancers and are able to generate a hierarchical and heterogeneous cancer cell population. CSCs are also resistant to conventional chemo- and radio-therapies. Here we report that ionizing radiation can induce stem cell-like properties in heterogeneous cancer cells. Exposure of non-stem cancer cells to ionizing radiation enhanced spherogenesis, and this was accompanied by upregulation of the pluripotency genes Sox2 and Oct3/4. Knockdown of Sox2 or Oct3/4 inhibited radiation-induced spherogenesis and increased cellular sensitivity to radiation. These data demonstrate that ionizing radiation can activate stemness pathways in heterogeneous cancer cells, resulting in the enrichment of a CSC subpopulation with higher resistance to radiotherapy.

  7. Diffuse ionizing radiation within HH jets

    Energy Technology Data Exchange (ETDEWEB)

    Esquivel, A.; Raga, A. C., E-mail: esquivel@nucleares.unam.mx, E-mail: raga@nucleares.unam.mx [Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México, Apartado Postal 70-543, 04510 Mexico D.F. (Mexico)

    2013-12-20

    We present numerical hydrodynamical simulations of a time-dependent ejection velocity precessing jet. The parameters used in our models correspond to a high excitation Herbig-Haro object, such as HH 80/81. We have included the transfer of ionizing radiation produced within the shocked regions of the jet. The radiative transfer is computed with a ray-tracing scheme from all the cells with an emissivity above a certain threshold. We show the development of a radiative precursor, and compare the morphology with a model without the diffuse radiation. Our simulations show that the morphology of the Hα emission is affected considerably if the diffuse ionizing radiation is accounted for. The predicted Hα position-velocity diagram (i.e., spatially resolved emission line profiles) from a model with the transfer of ionizing radiation has a relatively strong component at zero velocity, corresponding to the radiative precursor. Qualitatively similar 'zero velocity components' are observed in HH 80/81 and in the jet from Sanduleak's star in the Large Magellanic Cloud.

  8. 2010 Great Lakes Restoration Initiative Bathymetric Lidar: Lake Superior

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The data contained in this file contain hydrographic and topographic data collected by the Fugro LADS Mk II system along the Lake Superior coast of Minnessota,...

  9. 28 CFR 2.60 - Superior program achievement.

    Science.gov (United States)

    2010-07-01

    ... OF PRISONERS, YOUTH OFFENDERS, AND JUVENILE DELINQUENTS United States Code Prisoners and Parolees § 2... or a case with both superior program achievement and minor disciplinary infraction(s)). Advancements...

  10. Coronary artery bypass and superior vena cava syndrome.

    Science.gov (United States)

    Thomas, T V; Masrani, K; Thomas, J L

    1999-01-01

    Superior vena cava syndrome is the obstruction of the superior vena cava or its main tributaries by benign or malignant lesions. The syndrome causes edema and engorgement of the vessels on the face, neck, and arms, nonproductive cough, and dyspnea. We discuss the case of a 48-year-old obese diabetic woman who was admitted with unstable angina. She had previously been diagnosed with superior vena cava syndrome. Urgent coronary artery bypass grafting was necessary Although thousands of coronary artery bypasses are performed every year, there are not many reports on patients with superior vena cava syndrome who successfully undergo cardiopulmonary bypass and coronary artery grafting with an internal mammary artery as the conduit. The results of the case and alternative recommended methods are discussed.

  11. Testing a Dynamical Equilibrium Model of the Extraplanar Diffuse Ionized Gas in NGC 891

    CERN Document Server

    Boettcher, Erin; Gallagher, J S; Benjamin, Robert A

    2016-01-01

    The observed scale heights of extraplanar diffuse ionized gas (eDIG) layers exceed their thermal scale heights by a factor of a few in the Milky Way and other nearby edge-on disk galaxies. Here, we test a dynamical equilibrium model of the extraplanar diffuse ionized gas layer in NGC 891, where we ask whether the thermal, turbulent, magnetic field, and cosmic ray pressure gradients are sufficient to support the layer. In optical emission line spectroscopy from the SparsePak integral field unit on the WIYN 3.5-meter telescope, the H-alpha emission in position-velocity space suggests that the eDIG is found in a ring between galactocentric radii of R_min = 2 kpc. We find that the thermal (sigma_th = 11 km/s) and turbulent (sigma_turb = 25 km/s) velocity dispersions are insufficient to satisfy the hydrostatic equilibrium equation given an exponential electron scale height of h_z = 1.0 kpc. Using a literature analysis of radio continuum observations from the CHANG-ES survey, we demonstrate that the magnetic field ...

  12. Thermal Clothing

    Science.gov (United States)

    1997-01-01

    Gateway Technologies, Inc. is marketing and developing textile insulation technology originally developed by Triangle Research and Development Corporation. The enhanced thermal insulation stems from Small Business Innovation Research contracts from NASA's Johnson Space Center and the U.S. Air Force. The effectiveness of the insulation comes from the microencapsulated phase-change materials originally made to keep astronauts gloved hands warm. The applications for the product range from outer wear, housing insulation, and blankets to protective firefighting gear and scuba diving suits. Gateway has developed and begun marketing thermal regulating products under the trademark, OUTLAST. Products made from OUTLAST are already on the market, including boot and shoe liners, winter headgear, hats and caps for hunting and other outdoor sports, and a variety of men's and women's ski gloves.

  13. Ionization States of galaxies: Evolution, SFR-M_star-Z Dependence, and Ionizing Photon Escape

    CERN Document Server

    Nakajima, Kimihiko

    2013-01-01

    We present a systematic study for ionization states of galaxies at z=0-3 with ~140,000 SDSS galaxies and 108 intermediate to high redshift galaxies from the literature, using an ionization-parameter sensitive line ratio of [OIII]5007/[OII]3727 and photoionization models. We confirm that z=2-3 galaxies show an [OIII]/[OII] ratio significantly higher than typical local galaxies by a factor of >~10, and the photoionization models reveal that these high-z galaxies have an ionization parameter of log(qion/cm s^{-1})~7.6-9.0, a factor of ~4-10 higher than local galaxies. For galaxies at any redshifts, we identify a correlation between the [OIII]/[OII] ratio and galaxy global properties of star-formation rate (SFR), stellar mass (M_star), and metallicity (Z). We extend the fundamental metallicity relation (FMR; Mannucci et al. 2010; Lara-lopez et al. 2010), and develop the fundamental ionization relation (FIR), a four-dimensional relation of ionization parameter, SFR, M_star, and Z. The intermediate and high-z galax...

  14. Superior memorizers employ different neural networks for encoding and recall.

    Science.gov (United States)

    Mallow, Johannes; Bernarding, Johannes; Luchtmann, Michael; Bethmann, Anja; Brechmann, André

    2015-01-01

    Superior memorizers often employ the method of loci (MoL) to memorize large amounts of information. The MoL, known since ancient times, relies on a complex process where information to be memorized is bound to landmarks along mental routes in a previously memorized environment. However, functional magnetic resonance imaging data on groups of trained superior memorizer are rare. Based on the memorizing strategy reported by superior memorizers, we developed a scheme of the processes successively employed during memorizing and recalling digits and relate these to brain activation that is specific for the encoding and recall period. In the examined superior memorizers several regions, suggested to be involved in mental navigation and digit-to-word processing, were specifically activated during encoding: bilateral early visual cortex, retrosplenial cortex, left parahippocampus, left visual cortex, and left superior parietal cortex. Although the scheme suggests that some steps during encoding and recall seem to be analog, none of the encoding areas were specifically activated during the recall. Instead, we found strong activation in left anterior superior temporal gyrus, which we relate to recalling the sequential order of the digits, and right motor cortex that may be related to reciting the digits.

  15. Superior Memorizers Employ Different Neural Networks for Encoding and Recall

    Directory of Open Access Journals (Sweden)

    Johannes eMallow

    2015-09-01

    Full Text Available Superior memorizers often employ the method of loci (MoL to memorize large amounts of information. The method of loci, known since ancient times, relies on a complex process where information to be memorized is bound to landmarks along mental routes in a previously memorized environment. However, fMRI data on groups of trained superior memorizer are rare. Based on the memorizing strategy reported by superior memorizers we developed a scheme of the processes successively employed during memorizing and recalling digits and relate these to brain activation that is specific for the encoding and recall period. In the examined superior memorizers several regions, suggested to be involved in mental navigation and digit-to-word processing, were specifically activated during encoding: bilateral early visual cortex, retrosplenial cortex, left parahippocampus, left visual cortex, and left superior parietal cortex. Although the scheme suggests that some steps during encoding and recall seem to be analog, none of the encoding areas were specifically activated during the recall. Instead, we found strong activation in left anterior superior temporal gyrus, which we relate to recalling the sequential order of the digits, and right motor cortex that may be related to reciting the digits.

  16. Differential diagnosis of cervical radiculopathy and superior pulmonary sulcus tumor

    Institute of Scientific and Technical Information of China (English)

    GU Rui; KANG Ming-yang; GAO Zhong-li; ZHAO Jian-wu; WANG Jin-cheng

    2012-01-01

    Background The result would be disastrous if the superior pulmonary sulcus tumor (Pancoast tumor) was misdiagnosed as degenerative cervical spine diseases.The aim of this study was to investigate the differential diagnosis methods of cervical radiculopathy and superior pulmonary sulcus tumor.Methods Clinical manifestations,physical,and radiological findings of 10 patients,whose main complaints were radiating shoulder and arm pain and later were diagnosed with superior pulmonary sulcus tumor,were reviewed and compared with those of cervical radiculopathy.Results Superior pulmonary sulcus tumor patients have shorter mean history and fewer complaints of neck pain or limitation of neck movement.Physical examination showed almost normal cervical spine range of motion.Spurling's neck compression test was negative in all patients.Anteroposterior cervical radiographs showed the lack of pulmonary air at the top of the affected lung in all cases and first rib encroachment in one case.The diagnosis of superior pulmonary sulcus tumor can be further confirmed by CT and MRI.Conclusions By the method of combination of history,physical examination,and radiological findings,superior pulmonary sulcus tumor can be efficiently differentiated from cervical radiculopathy.Normal motion range of the cervical spine,negative Spurling's neck compression test,and the lack of pulmonary air at the top of the affected lung in anteroposterior cervical radiographs should be considerad as indications for further chest radiograph examinations.

  17. Thermal Conductivity of Carbon Nanotube Composite Films

    Science.gov (United States)

    Ngo, Quoc; Cruden, Brett A.; Cassell, Alan M.; Walker, Megan D.; Koehne, Jessica E.; Meyyappan, M.; Li, Jun; Yang, Cary Y.

    2004-01-01

    State-of-the-art ICs for microprocessors routinely dissipate power densities on the order of 50 W/sq cm. This large power is due to the localized heating of ICs operating at high frequencies, and must be managed for future high-frequency microelectronic applications. Our approach involves finding new and efficient thermally conductive materials. Exploiting carbon nanotube (CNT) films and composites for their superior axial thermal conductance properties has the potential for such an application requiring efficient heat transfer. In this work, we present thermal contact resistance measurement results for CNT and CNT-Cu composite films. It is shown that Cu-filled CNT arrays enhance thermal conductance when compared to as-grown CNT arrays. Furthermore, the CNT-Cu composite material provides a mechanically robust alternative to current IC packaging technology.

  18. Microwave Thermal Rockets—A Progress Report

    Science.gov (United States)

    Parkin, Kevin

    2008-04-01

    This paper reviews progress in microwave thermal rocket research since the concept was set forth in this forum 4 years ago. Since then, a microwave thermal thruster has been demonstrated in the laboratory for the first time, albeit at small scale. A numerical model has been developed that captures the behavior of this configuration and can be used to design future experiments, and system point designs have affirmed that a specific impulse of greater than 700 seconds and thrust to weight ratio of greater than 70 is quite possible. In future work, it remains to fully explore the wider design space and relative merits of microwave thermal rockets, delineating the operating regime in which microwave thermal rockets are superior to alternative approaches.

  19. Veia cava superior esquerda anômala com ausência de veia cava superior direita: achados de imagem Persistent left superior vena cava with absent right superior vena cava: image findings

    Directory of Open Access Journals (Sweden)

    Cyrillo Rodrigues de Araújo Júnior

    2003-10-01

    Full Text Available A persistência da veia cava superior esquerda com ausência da veia cava superior direita é uma anomalia rara, com menos de 150 casos descritos na literatura. A não-obliteração e regressão da veia cardinal anterior esquerda durante o desenvolvimento embriológico promove uma variação sistêmica de retorno venoso ao coração, com persistência da veia cava superior esquerda. Sua incidência varia de 0,3% em pacientes sem alterações cardíacas congênitas concomitantes a 4,3% naqueles com cardiopatias. Na maioria das vezes coexiste a veia cava superior direita, porém se houver regressão e degeneração da veia cardinal anterior direita, implicará a sua ausência e a drenagem venosa para o coração será feita pela veia cava superior esquerda ao átrio direito, através do seio coronariano. Mostramos um caso de um paciente submetido a radiografia de tórax e tomografia computadorizada para avaliação de doença pulmonar obstrutiva crônica, tendo como achado a persistência da veia cava superior esquerda com ausência da direita, sem qualquer cardiopatia associada e com a drenagem cardíaca sendo feita, através do seio coronariano, para o átrio direito.Persistent left superior vena cava with absent right superior vena cava is a rare anomaly, with less than 150 cases reported in the literature. Congenitally persistent left superior vena cava is the most common variant of systemic venous return to the heart, resulting embryologically from failure of the left anterior cardinal vein to become obliterated. Its incidence varies from 0.3% in patients with otherwise normal heart to 4.3% in patients with congenital heart disease. In the majority of the patients, a right superior vena cava is present as well, but rarely the right anterior cardinal vein degenerates resulting in the absence of the normal right superior vena cava. The blood from the right side is carried by the persistent left superior vena cava to the right atrium through the

  20. Orientation-dependent ionization yields from strong-field ionization of fixed-in-space linear and asymmetric top molecules

    CERN Document Server

    Hansen, Jonas L; Nielsen, Jens H; Stapelfeldt, Henrik; Dimitrovski, Darko; Madsen, Lars Bojer

    2011-01-01

    The yield of strong-field ionization, by a linearly polarized probe pulse, is studied experimentally and theoretically, as a function of the relative orientation between the laser field and the molecule. Experimentally, carbonyl sulfide, benzonitrile and naphthalene molecules are aligned in one or three dimensions before being singly ionized by a 30 fs laser pulse centered at 800 nm. Theoretically, we address the behaviour of these three molecules. We consider the degree of alignment and orientation and model the angular dependence of the total ionization yield by molecular tunneling theory accounting for the Stark shift of the energy level of the ionizing orbital. For naphthalene and benzonitrile the orientational dependence of the ionization yield agrees well with the calculated results, in particular the observation that ionization is maximized when the probe laser is polarized along the most polarizable axis. For OCS the observation of maximum ionization yield when the probe is perpendicular to the intern...

  1. Determination of the first ionization potential of actinides by resonance ionization mass spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Koehler, S. [Institut fuer Kernchemie Universitaet Mainz, Mainz (Germany); Albus, F. [Institu fuer Physik, Universitaet Mainz, Mainz (Germany); Dibenberger, R.; Erdmann, N.; Funk, H. [Institut fuer Kernchemiess Universitaet Mainz, Mainz (Germany); Hasse, H. [Institut fuer Physik, Universitaet Mainz, Mainz (Germany); Herrmann, G. [Institut fuer Kernchemiess Universitaet Mainz, Mainz (Germany); Huber, G.; Kluge, H.; Nunnemann, M.; Passler, G. [Institut fuer Physik, Universitaet Mainz, Mainz (Germany); Rao, P.M. [Bhabha Atomic Research Centre Bombay (India); Riegel, J.; Trautmann, N. [Institut fuer Kernchemie Universitaet Mainz, Mainz (Germany); Urban, F. [Institut fuer Physik, Universitaet Mainz, Mainz (Germany)

    1995-04-01

    Resonance ionization mass spectroscopy (RIMS) is used for the precise determination of the first ionization potential of transuranium elements. The first ionization potentials (IP) of americium and curium have been measured for the first time to IP{sub {ital Am}}=5.9738(2) and IP{sub {ital Cm}}=5.9913(8) eV, respectively, using only 10{sup 12} atoms of {sup 243}Am and {sup 248}Cm. The same technique was applied to thorium, neptunium, and plutonium yielding IP{sub T{sub H}}=6.3067(2), IP{sub N{sub P}}=6.2655(2), and IP{sub {ital Pu}}=6.0257(8) eV. The good agreement of our results with the literature data proves the precision of the method which was additionally confirmed by the analysis of Rydberg seris of americium measured by RIMS. {copyright}American Institute of Physics 1995

  2. A Miniaturized Linear Wire Ion Trap with Electron Ionization and Single Photon Ionization Sources

    Science.gov (United States)

    Wu, Qinghao; Tian, Yuan; Li, Ailin; Andrews, Derek; Hawkins, Aaron R.; Austin, Daniel E.

    2017-05-01

    A linear wire ion trap (LWIT) with both electron ionization (EI) and single photon ionization (SPI) sources was built. The SPI was provided by a vacuum ultraviolet (VUV) lamp with the ability to softly ionize organic compounds. The VUV lamp was driven by a pulse amplifier, which was controlled by a pulse generator, to avoid the detection of photons during ion detection. Sample gas was introduced through a leak valve, and the pressure in the system is shown to affect the signal-to-noise ratio and resolving power. Under optimized conditions, the limit of detection (LOD) for benzene was 80 ppbv using SPI, better than the LOD using EI (137 ppbv). System performance was demonstrated by distinguishing compounds in different classes from gasoline.

  3. Heating and ionization of metal clusters in the field of an intense femtosecond laser pulse

    Science.gov (United States)

    Kostenko, O. F.; Andreev, N. E.

    2007-06-01

    Inverse bremsstrahlung heating and thermal electron-impact ionization of a metal cluster are analyzed with account for the spatial structure of the electromagnetic field. It is shown that, for a femtosecond IR radiation pulse with an intensity of ˜1018 W/cm2 and for an iron cluster with an optimum radius of ˜25 nm, the electron temperature is higher than 1 keV. In this case, the L shell of the ions is highly stripped. The X-ray bremsstrahlung yield from clusters with a radius greater than the skin depth is estimated.

  4. Analytical models for total dose ionization effects in MOS devices.

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, Phillip Montgomery; Bogdan, Carolyn W.

    2008-08-01

    MOS devices are susceptible to damage by ionizing radiation due to charge buildup in gate, field and SOI buried oxides. Under positive bias holes created in the gate oxide will transport to the Si / SiO{sub 2} interface creating oxide-trapped charge. As a result of hole transport and trapping, hydrogen is liberated in the oxide which can create interface-trapped charge. The trapped charge will affect the threshold voltage and degrade the channel mobility. Neutralization of oxidetrapped charge by electron tunneling from the silicon and by thermal emission can take place over long periods of time. Neutralization of interface-trapped charge is not observed at room temperature. Analytical models are developed that account for the principal effects of total dose in MOS devices under different gate bias. The intent is to obtain closed-form solutions that can be used in circuit simulation. Expressions are derived for the aging effects of very low dose rate radiation over long time periods.

  5. Unimolecular thermal decomposition of dimethoxybenzenes

    Science.gov (United States)

    Robichaud, David J.; Scheer, Adam M.; Mukarakate, Calvin; Ormond, Thomas K.; Buckingham, Grant T.; Ellison, G. Barney; Nimlos, Mark R.

    2014-06-01

    The unimolecular thermal decomposition mechanisms of o-, m-, and p-dimethoxybenzene (CH3O-C6H4-OCH3) have been studied using a high temperature, microtubular (μtubular) SiC reactor with a residence time of 100 μs. Product detection was carried out using single photon ionization (SPI, 10.487 eV) and resonance enhanced multiphoton ionization (REMPI) time-of-flight mass spectrometry and matrix infrared absorption spectroscopy from 400 K to 1600 K. The initial pyrolytic step for each isomer is methoxy bond homolysis to eliminate methyl radical. Subsequent thermolysis is unique for each isomer. In the case of o-CH3O-C6H4-OCH3, intramolecular H-transfer dominates leading to the formation of o-hydroxybenzaldehyde (o-HO-C6H4-CHO) and phenol (C6H5OH). Para-CH3O-C6H4-OCH3 immediately breaks the second methoxy bond to form p-benzoquinone, which decomposes further to cyclopentadienone (C5H4=O). Finally, the m-CH3O-C6H4-OCH3 isomer will predominantly follow a ring-reduction/CO-elimination mechanism to form C5H4=O. Electronic structure calculations and transition state theory are used to confirm mechanisms and comment on kinetics. Implications for lignin pyrolysis are discussed.

  6. Oxygen ionization rates at Mars and Venus - Relative contributions of impact ionization and charge exchange

    Science.gov (United States)

    Zhang, M. H. G.; Luhmann, J. G.; Nagy, A. F.; Spreiter, J. R.; Stahara, S. S.

    1993-01-01

    Oxygen ion production rates above the ionopauses of Venus and Mars are calculated for photoionization, charge exchange, and solar wind electron impact ionization processes. The latter two require the use of the Spreiter and Stahara (1980) gas dynamic model to estimate magnetosheath velocities, densities, and temperatures. The results indicate that impact ionization is the dominant mechanism for the production of O(+) ions at both Venus and Mars. This finding might explain both the high ion escape rates measured by Phobos 2 and the greater mass loading rate inferred for Venus from the bow shock positions.

  7. Thermal insulator

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, R.; Asada, Y.; Matsuo, Y.; Mikoda, M.

    1985-07-16

    A thermal insulator comprises an expanded resin body having embedded therein an evacuated powder insulation portion which consists of fine powder and a container of film-like plastics or a film-like composite of plastics and metal for enclosing the powder. The resin body has been expanded by a Freon gas as a blowing agent. Since a Freon gas has a larger molecular diameter than the constituent gases of air, it is less likely to permeate through the container than air. Thus present invention provides a novel composite insulator which fully utilizes the benefits of vacuum insulation without necessitating a strong and costly material for a vacuum container.

  8. Thermal Relativity

    Institute of Scientific and Technical Information of China (English)

    赵柳

    2011-01-01

    The group G of general coordinate transformations on the thermodynamic configuration space ε spanned by all the extensive variables keeps the first law of thermodynamics invariant. One can introduce a metric with Lorentzian signature on the space ε, with the corresponding line element also being invariant under the action of G. This line element is identi6ed as the square of the proper entropy. Thus the second law of thermodynamics is also formulated invariantly and this lays down the foundation for the principle of thermal relativity.

  9. Spectroscopic study of local thermal effect in transparent glass ceramics containing nanoparticles

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Local thermal effect influencing the fluorescence of triply ionized rare earth ions doped in nanocrystals is studied with laser spectroscopy and theory of thermal transportation for transparent oxyfluoride glass ceramics containing nanocrystals. The result shows that the local temperature of the nanocrystals embedded in glass matrices is much higher than the environmental temperature of the sample. It is suggested that the temperature-dependent thermal energy induced by the light absorption must be considered when the theory of thermal transportation is applied to the study of local thermal effect.

  10. Ionization photophysics and spectroscopy of dicyanoacetylene

    Energy Technology Data Exchange (ETDEWEB)

    Leach, Sydney, E-mail: Sydney.Leach@obspm.fr, E-mail: Martin.Schwell@lisa.u-pec.fr; Champion, Norbert [LERMA UMR CNRS 8112, Observatoire de Paris-Meudon, 5 place Jules-Jansen, 92195 Meudon (France); Schwell, Martin, E-mail: Sydney.Leach@obspm.fr, E-mail: Martin.Schwell@lisa.u-pec.fr; Bénilan, Yves; Fray, Nicolas; Gazeau, Marie-Claire [LISA UMR CNRS 7583, Université Paris-Est Créteil and Université Paris Diderot, Institut Pierre Simon Laplace, 61 Avenue du Général de Gaulle, 94010 Créteil (France); Garcia, Gustavo A.; Gaie-Levrel, François [Synchrotron SOLEIL, L’Orme des Merisiers, St. Aubin, B.P. 48, 91192 Gif-sur-Yvette Cedex (France); Guillemin, Jean-Claude [Institut des Sciences Chimiques de Rennes, Ecole Nationale Supérieure de Chimie de Rennes, CNRS UMR 6226, 11 Allée de Beaulieu, CS 50837, 35708 Rennes Cedex 7 (France)

    2013-11-14

    Photoionization of dicyanoacetylene was studied using synchrotron radiation over the excitation range 8–25 eV, with photoelectron-photoion coincidence techniques. The absolute ionization cross-section and detailed spectroscopic aspects of the parent ion were recorded. The adiabatic ionization energy of dicyanoacetylene was measured as 11.80 ± 0.01 eV. A detailed analysis of the cation spectroscopy involves new aspects and new assignments of the vibrational components to excitation of the quasi-degenerate A{sup 2}Π{sub g}, B{sup 2}Σ{sub g}{sup +} states as well as the C{sup 2}Σ{sub u}{sup +} and D{sup 2}Π{sub u} states of the cation. Some of the structured autoionization features observed in the 12.4–15 eV region of the total ion yield spectrum were assigned to vibrational components of valence shell transitions and to two previously unknown Rydberg series converging to the D{sup 2}Π{sub u} state of C{sub 4}N{sub 2}{sup +}. The appearance energies of the fragment ions C{sub 4}N{sup +}, C{sub 3}N{sup +}, C{sub 4}{sup +}, C{sub 2}N{sup +}, and C{sub 2}{sup +} were measured and their heats of formation were determined and compared with existing literature values. Thermochemical calculations of the appearance potentials of these and other weaker ions were used to infer aspects of dissociative ionization pathways.

  11. Ionization pattern obtained in electrospray ionization or atmospheric pressure chemical ionization interfaces for authorized antidepressants in Romania

    Science.gov (United States)

    Grecu, Iulia; Ionicǎ, Mihai; Vlǎdescu, Marian; Truţǎ, Elena; Sultan, Carmen; Viscol, Oana; Horhotǎ, Luminiţa; Radu, Simona

    2016-12-01

    Antidepressants were found in 1950. In the 1990s there was a new generation of antidepressants. They act on the level of certain neurotransmitters extrasinpatic by its growth. After their mode of action antidepressants may be: SSRIs (Selective Serotonin Reuptake Inhibitors); (Serotonin-Norepinephrine Reuptake Inhibitors); SARIs (Serotonin Antagonist Reuptake Inhibitors); NRIs (Norepinephrine Reuptake Inhibitors); NDRIs (Norepinephrine-Dopamine Reuptake Inhibitors) NDRAs (Norepinephrine-Dopamine Releasing Agents); TCAs (Tricyclic Antidepressants); TeCAs (Tetracyclic Antidepressants); MAOIs (Monoamine Oxidase Inhibitors); agonist receptor 5-HT1A (5- hydroxytryptamine); antagonist receptor 5-HT2; SSREs (Selective Serotonin Reuptake Enhancers) and Sigma agonist receptor. To determine the presence of antidepressants in biological products, it has been used a system HPLC-MS (High Performance Liquid Chromatography - Mass Spectrometry) Varian 12001. The system is equipped with APCI (Atmospheric Pressure Chemical Ionization) or ESI (ElectroSpray Ionization) interface. To find antidepressants in unknown samples is necessary to recognize them after mass spectrum. Because the mass spectrum it is dependent on obtaining private parameters work of HPLC-MS system, and control interfaces, the mass spectra library was filled with the mass spectra of all approved antidepressants in Romania. The paper shows the mass spectra obtained in the HPLCMS system.

  12. Ionization chemistry in the H2O-dominant atmospheres of the icy moons

    Science.gov (United States)

    Shematovich, V. I.; Johnson, R. E.

    2007-08-01

    The main pathways of the ionization chemistry for pure H2O- and mixed H2O+O2+CO2+NH3+CH4 atmospheres which are representative for neutral and ionized atmospheres of the icy bodies in the Jovian and Saturnian systems are discussed. The gaseous envelopes of the icy moons of the giant planets are formed usually due to the surface radiolysis by the solar UV radiation and energetic magnetospheric plasma (Johnson, 1990). The standard astrochemical UMIST2005 (UDFA05) network is used to infer the main chemical pathways of ionization chemistry in the pure or with admixtures of other volatile molecules water vapor atmospheres. In case of the H2O- dominant atmosphere the parent H2O molecules are easily dissociated and ionized by the solar UVradiation and the energetic magnetospheric electrons. These impact processes result in the formation of the secondary neutral and ionized products - chemically active radicals O and OH, and H+, H2+, O+, OH+, and H2O+ ions. Secondary ions have admixture abundances in the H2O-dominant atmospheres, because they are efficiently transformed to H3O+ hydroxonium ions in the fast ion-molecular reactions. The major H3O+ hydroxonium ion does not chemically interact with other neutrals, and is destroyed in the dissociative recombination with thermal electrons mainly reproducing the chemically simple H, H2, O, and OH species. In case of the mixed H2O+O2-dominant atmosphere corresponding to the near-surface atmospheres of icy moons (Shematovich et al., 2005), the ionization chemistry results in the formation of the second major ion O2+ - because ion of molecular oxygen has the lower ionization potential comparing with other parent species -H2, H2O, CO2. The H+, O+, OH+, and H2O+ ions can be easily converted to O2+ ions through the ion-molecular reactions. In case of significant admixture of molecular hydrogen it is possible to transfer the O2+ ions to the O2H+ ions through the fast reaction with H2 and further to the H3O+ ions through the ion

  13. Superior Canal Dehiscence Syndrome: Lessons from the First 20 Years

    Directory of Open Access Journals (Sweden)

    Bryan K. Ward

    2017-04-01

    Full Text Available Superior semicircular canal dehiscence syndrome was first reported by Lloyd Minor and colleagues in 1998. Patients with a dehiscence in the bone overlying the superior semicircular canal experience symptoms of pressure or sound-induced vertigo, bone conduction hyperacusis, and pulsatile tinnitus. The initial series of patients were diagnosed based on common symptoms, a physical examination finding of eye movements in the plane of the superior semicircular canal when ear canal pressure or loud tones were applied to the ear, and high-resolution computed tomography imaging demonstrating a dehiscence in the bone over the superior semicircular canal. Research productivity directed at understanding better methods for diagnosing and treating this condition has substantially increased over the last two decades. We now have a sound understanding of the pathophysiology of third mobile window syndromes, higher resolution imaging protocols, and several sensitive and specific diagnostic tests. Furthermore, we have a treatment (surgical occlusion of the superior semicircular canal that has demonstrated efficacy. This review will highlight some of the fundamental insights gained in SCDS, propose diagnostic criteria, and discuss future research directions.

  14. La educación superior como eje del desarrollo

    Directory of Open Access Journals (Sweden)

    Benjamín Afanador Vargas

    2003-11-01

    Full Text Available Este documento analiza cómo ha sido la interacción entre la política educativa y las estrategiasde desarrollo en Colombia, a lo largo del siglo XX. Se presenta una revisión del estadoactual de la educación en Colombia, tanto a nivel de educación básica y media, como de laeducación superior. Para ello se toman tres criterios básicos que son la cobertura, la calidady la equidad en el acceso a la educación. Para el caso de la educación superior, se comparala oferta de cupos con la demanda existente, se clasifican los distintos segmentos en que sedivide la educación superior y se hace una breve reseña sobre el recurso humano con que secuenta en la educación superior colombiana. Así mismo, se expone una conceptualización delos retos que enfrenta la educación superior, sobretodo para lograr una cohesión de la sociedad,evitando que algunos de sus integrantes sean excluidos y permitiendo que todos losestamentos de la sociedad puedan compartir los mismos ideales y los consideren asequibles.Finalmente, se presentan unas conclusiones que se derivan del estudio y se proponen algunasrecomendaciones de política .

  15. Resonance ionization detection of combustion radicals

    Energy Technology Data Exchange (ETDEWEB)

    Cool, T.A. [Cornell Univ., Ithaca, NY (United States)

    1993-12-01

    Fundamental research on the combustion of halogenated organic compounds with emphasis on reaction pathways leading to the formation of chlorinated aromatic compounds and the development of continuous emission monitoring methods will assist in DOE efforts in the management and disposal of hazardous chemical wastes. Selective laser ionization techniques are used in this laboratory for the measurement of concentration profiles of radical intermediates in the combustion of chlorinated hydrocarbon flames. A new ultrasensitive detection technique, made possible with the advent of tunable VUV laser sources, enables the selective near-threshold photoionization of all radical intermediates in premixed hydrocarbon and chlorinated hydrocarbon flames.

  16. Nucleation in an ultra low ionization environment

    DEFF Research Database (Denmark)

    Pedersen, Jens Olaf Pepke; Enghoff, Martin Andreas Bødker; Paling, Sean

    filter in order to reduce the Radon concentration. In this way we have been able to make nucleation experiments with very low ionizing background, meaning that we can rule out ion induced nucleation as a contributing mechanism. Our experimental setup is a 50 L electropolished stainless steel reactor...... at near atmospheric conditions. The chamber contains clean air with the addition of water vapour, ozone, and SO2. Using UV lights at 254 nm ozone is photolyzed, leading to the production of sulphuric acid and thus aerosols. An 18 MBq Caesium-137 gamma ray source with various amounts of lead in front...

  17. A website dedicated to ionizing radiation metrology

    Energy Technology Data Exchange (ETDEWEB)

    Dulieu, Christophe E-mail: christophe.dulieu@cea.fr; Chiste, Vanessa; Be, M.-M

    2004-04-01

    In order to disseminate information about decay data and their evaluation, as well as other topics in the field of ionizing radiation, the Bureau National de Metrologie-Laboratoire National Henri Becquerel (BNM-LNHB) has published a website. Most of the web pages are concerned with the international working groups in which the BNM-LNHB takes part. In particular, a library of uranium and plutonium spectra is now available, as well as the results of evaluation of decay data of nuclides of special interest.

  18. Monitoring occupational exposure to ionizing radiation

    Energy Technology Data Exchange (ETDEWEB)

    Button, J.B.C. [Radiation Safety Consultancy, Engadine, NSW (Australia)

    1997-12-31

    A brief overview is presented of methods of monitoring occupational exposure to ionizing radiation together with reasons for such monitoring and maintaining dose histories of radiation occupationally exposed persons. The various Australian providers of external radiation monitoring services and the types of dosemeters they supply are briefly described together with some monitoring results. Biological monitoring methods, are used to determine internal radiation dose. Whole body monitors, used for this purpose are available at Australian Radiation Lab., ANSTO and a few hospitals. Brief mention is made of the Australian National Radiation Dose Register and its objectives. 8 refs., 9 tabs.

  19. A website dedicated to ionizing radiation metrology.

    Science.gov (United States)

    Dulieu, Christophe; Chisté, Vanessa; Bé, Marie-Martine

    2004-01-01

    In order to disseminate information about decay data and their evaluation, as well as other topics in the field of ionizing radiation, the Bureau National de Métrologie-Laboratoire National Henri Becquerel (BNM-LNHB) has published a website. Most of the web pages are concerned with the international working groups in which the BNM-LNHB takes part. In particular, a library of uranium and plutonium spectra is now available, as well as the results of evaluation of decay data of nuclides of special interest.

  20. Double ionization of two-electron systems

    Energy Technology Data Exchange (ETDEWEB)

    Ancarani, L U; Cappello, C Dal [Laboratoire de Physique Moleculaire et des Collisions, Universite Paul Verlaine - Metz, 57078 Metz (France); Gasaneo, G, E-mail: ancarani@univ-metz.f [Departamento de Fisica, Universidad Nacional del Sur and Consejo Nacional de Investigaciones CientIficas y Tecnicas, 8000 BahIa Blanca, Buenos Aires (Argentina)

    2010-02-01

    We address various issues related to the double ionization by electron impact of two-electron systems. The emphasis will be put on the theoretical description of high incident energy (e,3e) processes, for which the first Born approximation should be suitable. In the case of helium, absolute experimental data for fivefold differential cross sections are available in coplanar geometry. We will review and discuss the divergencies existing between the results obtained with different theoretical models, and those appearing when compared to the experiments in particular with respect to the absolute scale. We will then discuss some results obtained in a recently proposed out of plane geometry.

  1. Ionization Chamber for Prompt Fission Neutron Investigations

    OpenAIRE

    ZEYNALOV Sh.; ZEYNALOVA O. V.; Hambsch, Franz-Josef; Sedyshev, P.; SHVETSOV V.

    2014-01-01

    In this work we report recent achievements in design of twin back-to-back ionization chamber (TIC) for fission fragment (FF) mass and kinetic energy measurement. Correlated FF kinetic energies, their masses and the angle of FF in respect to the axes in 3D Cartesian coordinates can be determined from analysis of the heights and shapes of the pulses induced by the fission fragments on the anodes of TIC. Anodes of TIC were designed as consisting of isolated strips each having independent electro...

  2. Multiphoton dissociation and ionization of nickelocene

    Science.gov (United States)

    Leutwyler, Samuel; Even, Uzi; Jortner, Joshua

    1981-01-01

    In this paper we report the results of an experimental study of collision-free molecular multiphoton dissociation (MPD) and molecular multiphoton ionization (MPI) of nickelocene (NiC 10H 10), induced by the light of a tunable dye laser in the wavelength region 3750-5200 A. The spectral dependence of the ion signal reveals a multitude of narrow (fwhm from <0.5 cm -1 to 1.5 cm -1) intense peaks superimposed on a very weak background (relative amplitude ratio for peaks/background ≈ 10 3). The sharp resonances in the ion signal are attributed, on the basis of spectroscopic analysis, to two-photon resonant three-photon ionization of Ni(I) and to one-photon resonant three-photon ionization of Ni(I), the Ni(I) being produced by MPD of nickelocene. The ion signal in the spectral range 3750-3950 A reveals enhanced continuous background due to MPI of nickelocene. This ion signal spectra, together with studies of the intensity dependence of the overall (nickelocene MPD) - (Ni(I) MPI) processes, as well as the (nickelocene molecular MPI) reaction, reveal four reactive processes. (a) Two-photon molecular MPI for hω ⩾ 3.10 eV photons. (b) Three-photon molecular MPI for hω = 3.10-2.10 eV. (c) Two-photon MPD at hω ⩾ 2.86 eV. (d) Three-photon MPD for hω = 2.8-1.9 eV. The overall dissociation energy of nickelocene (Nicp 2) to give Ni + 2cp was determined to be 5.76 ± 0.60 eV and the two-photon ionization potential of this molecule is 6.29 ± 0.015 eV. Our results provide dynamic evidence concerning a simultaneous "explosive" photodissociation mechanism of Nicp 2 by process (c) and for the dominating role of the dissociative channel, characterized by a branching ratio of ⩾50 in favor of predissociation over autoionization, for process (c) at 6.3-6.6 eV. The MPD processes (c) and (d) are expected to exhibit intramolecular erosion of phase coherence effects. Processes (c) and (d) are of high efficiency ≈0.01 ions/molecule at saturation exhibited at laser power of ≈ 10

  3. LET measurements with a Liquid Ionization Chamber

    OpenAIRE

    Tegami, S.

    2013-01-01

    Deep-seated tumors can be efficiently treated with heavy charged particles. The characteristic depth dose profile inside the tissue (Bragg peak) allows to deliver a high dose inside the tumor, while sparing the neighboring healthy tissue. As compared to protons, heavy ions like carbon or oxygen produce a higher amount of ionization events along their track (and in particular at the end of the ion beam path), resulting in an irreparable damage to the DNA of the tumor cells. The density of such...

  4. Microtron for Smog Particles Photo Ionization

    CERN Document Server

    Dolya, S N

    2016-01-01

    The article discusses a possibility of removing smog particles from a boiler smoke. To do this, the boiler smoke is passed through a flow of gamma radiation, formed by interaction of the microtron beam with a heavy target. The energy of the microtron electrons twenty five megaelectronvolts, the beam current one hundred microamperes. Smog particles are ionized with gamma radiation and then sat down on the plates of the electrostatic filter. The height of the filter plates is one m, the electric field between the plates one kilovolt per centimeter. The smog particles on the plates should be removed regularly to a specialized dust collector.

  5. Ionization of EPA contaminants in direct and dopant-assisted atmospheric pressure photoionization and atmospheric pressure laser ionization.

    Science.gov (United States)

    Kauppila, Tiina J; Kersten, Hendrik; Benter, Thorsten

    2015-06-01

    Seventy-seven EPA priority environmental pollutants were analyzed using gas chromatography-mass spectrometry (GC-MS) equipped with an optimized atmospheric pressure photoionization (APPI) and an atmospheric pressure laser ionization (APLI) interface with and without dopants. The analyzed compounds included e.g., polycyclic aromatic hydrocarbons (PAHs), nitro compounds, halogenated compounds, aromatic compounds with phenolic, acidic, alcohol, and amino groups, phthalate and adipatic esters, and aliphatic ethers. Toluene, anisole, chlorobenzene, and acetone were tested as dopants. The widest range of analytes was ionized using direct APPI (66/77 compounds). The introduction of dopants decreased the amount of compounds ionized in APPI (e.g., 54/77 with toluene), but in many cases the ionization efficiency increased. While in direct APPI the formation of molecular ions via photoionization was the main ionization reaction, dopant-assisted (DA) APPI promoted ionization reactions, such as charge exchange and proton transfer. Direct APLI ionized a much smaller amount of compounds than APPI (41/77 compounds), showing selectivity towards compounds with low ionization energies (IEs) and long-lived resonantly excited intermediate states. DA-APLI, however, was able to ionize a higher amount of compounds (e.g. 51/77 with toluene), as the ionization took place entirely through dopant-assisted ion/molecule reactions similar to those in DA-APPI. Best ionization efficiency in APPI and APLI (both direct and DA) was obtained for PAHs and aromatics with O- and N-functionalities, whereas nitro compounds and aliphatic ethers were the most difficult to ionize. Halogenated aromatics and esters were (mainly) ionized in APPI, but not in APLI.

  6. Determination of iodine in oyster tissue by isotope dilution laser resonance ionization mass spectrometry.

    Science.gov (United States)

    Fassett, J D; Murphy, T J

    1990-02-15

    The technique of laser resonance ionization mass spectrometry has been combined with isotope dilution analysis to determine iodine in oyster tissue. The long-lived radioisotope, 129I, was used to spike the samples. Samples were equilibrated with the 129I, wet ashed under controlled conditions, and iodine separated by coprecipitation with silver chloride. The analyte was dried as silver ammonium iodide upon a tantalum filament from which iodine was thermally desorbed in the resonance ionization mass spectrometry instrument. A single-color, two-photon resonant plus one-photon ionization scheme was used to form positive iodine ions. Long-lived iodine signals were achieved from 100 ng of iodine. The precision of 127I/129I measurement has been evaluated by replicate determinations of the spike, the spike calibration samples, and the oyster tissue samples and was 1.0%. Measurement precision among samples was 1.9% for the spike calibration and 1.4% for the oyster tissue. The concentration of iodine determined in SRM 1566a, Oyster Tissue, was 4.44 micrograms/g with an estimate of the overall uncertainty for the analysis of +/- 0.12 microgram/g.

  7. All-solid-state deep ultraviolet laser for single-photon ionization mass spectrometry.

    Science.gov (United States)

    Yuan, Chengqian; Liu, Xianhu; Zeng, Chenghui; Zhang, Hanyu; Jia, Meiye; Wu, Yishi; Luo, Zhixun; Fu, Hongbing; Yao, Jiannian

    2016-02-01

    We report here the development of a reflectron time-of-flight mass spectrometer utilizing single-photon ionization based on an all-solid-state deep ultraviolet (DUV) laser system. The DUV laser was achieved from the second harmonic generation using a novel nonlinear optical crystal KBe2BO3F2 under the condition of high-purity N2 purging. The unique property of this laser system (177.3-nm wavelength, 15.5-ps pulse duration, and small pulse energy at ∼15 μJ) bears a transient low power density but a high single-photon energy up to 7 eV, allowing for ionization of chemicals, especially organic compounds free of fragmentation. Taking this advantage, we have designed both pulsed nanospray and thermal evaporation sources to form supersonic expansion molecular beams for DUV single-photon ionization mass spectrometry (DUV-SPI-MS). Several aromatic amine compounds have been tested revealing the fragmentation-free performance of the DUV-SPI-MS instrument, enabling applications to identify chemicals from an unknown mixture.

  8. Ionization of Interstellar Hydrogen Beyond the Termination Shock

    Science.gov (United States)

    Gruntman, Mike

    2016-11-01

    Models of solar wind interaction with the surrounding interstellar medium usually disregard ionization of interstellar hydrogen atoms beyond the solar wind termination shock. If and when included, the effects of ionization in the heliospheric interface region are often obscured by complexities of the interaction. This work assesses the importance of interstellar hydrogen ionization in the heliosheath. Photoionization could be accounted for in a straightforward way. In contrast, electron impact ionization is largely unknown because of poorly understood energy transfer to electrons at the termination shock and beyond. We first estimate the effect of photoionization and then use it as a yardstick to assess the role of electron impact ionization. The physical estimates show that ionization of interstellar hydrogen may lead to significant mass loading in the inner heliosheath which would slow down plasma flowing toward the heliotail and deplete populations of nonthermal protons, with the corresponding effect on heliospheric fluxes of energetic neutral atoms.

  9. Smart ionization chamber for gamma-ray monitoring

    Directory of Open Access Journals (Sweden)

    Drndarević Vujo R.

    2014-01-01

    Full Text Available A design and implementation of a smart ionization chamber suitable for connection into gamma radiation monitoring networks is presented in this paper. The smart ionization chamber consists of air-equivalent one liter ionization chamber with associated electronics and a built-in memory for storage of electronic data specifications. Generally, operating and measurement characteristics of the used ionization chamber are written into the memory chip attached to the chamber. A microcontroller-based data acquisition system with a mixed-mode interface has been implemented for the purpose of reading electronic data specifications from the memory chip, and for configuration and interfacing of the ionization chamber to the monitoring network using plug-and-play concept. The details of smart ionization chamber implementation and test results are included in the paper. [Projekat Ministarstva nauke Republike Srbije, br. TR36047 i br. TR32043

  10. Modeling of Ionization Physics with the PIC Code OSIRIS

    Energy Technology Data Exchange (ETDEWEB)

    Deng, S.; Tsung, F.; Lee, S.; Lu, W.; Mori, W.B.; Katsouleas, T.; Muggli, P.; Blue, B.E.; Clayton, C.E.; O' Connell, C.; Dodd, E.; Decker, F.J.; Huang, C.; Hogan, M.J.; Hemker, R.; Iverson, R.H.; Joshi, C.; Ren, C.; Raimondi, P.; Wang, S.; Walz, D.; /Southern California U. /UCLA /SLAC

    2005-09-27

    When considering intense particle or laser beams propagating in dense plasma or gas, ionization plays an important role. Impact ionization and tunnel ionization may create new plasma electrons, altering the physics of wakefield accelerators, causing blue shifts in laser spectra, creating and modifying instabilities, etc. Here we describe the addition of an impact ionization package into the 3-D, object-oriented, fully parallel PIC code OSIRIS. We apply the simulation tool to simulate the parameters of the upcoming E164 Plasma Wakefield Accelerator experiment at the Stanford Linear Accelerator Center (SLAC). We find that impact ionization is dominated by the plasma electrons moving in the wake rather than the 30 GeV drive beam electrons. Impact ionization leads to a significant number of trapped electrons accelerated from rest in the wake.

  11. Development of a Portable Single Photon Ionization-Photoelectron Ionization Time-of-Flight Mass Spectrometer

    Directory of Open Access Journals (Sweden)

    Yunguang Huang

    2015-01-01

    Full Text Available A vacuum ultraviolet lamp based single photon ionization- (SPI- photoelectron ionization (PEI portable reflecting time-of-flight mass spectrometer (TOFMS was designed for online monitoring gas samples. It has a dual mode ionization source: SPI for analyte with ionization energy (IE below 10.6 eV and PEI for IE higher than 10.6 eV. Two kinds of sampling inlets, a capillary inlet and a membrane inlet, are utilized for high concentration and trace volatile organic compounds, respectively. A mass resolution of 1100 at m/z 64 has been obtained with a total size of 40 × 31 × 29 cm, the weight is 27 kg, and the power consumption is only 70 W. A mixture of benzene, toluene, and xylene (BTX, SO2, and discharging products of SF6 were used to test its performance, and the result showed that the limit of quantitation for BTX is as low as 5 ppbv (S/N = 10 : 1 with linear dynamic ranges greater than four orders of magnitude. The portable TOFMS was also evaluated by analyzing volatile organic compounds from wine and decomposition products of SF6 inside of a gas-insulated switchgear.

  12. Lattice design and expected performance of the Muon Ionization Cooling Experiment demonstration of ionization cooling

    Directory of Open Access Journals (Sweden)

    2017-06-01

    Full Text Available Muon beams of low emittance provide the basis for the intense, well-characterized neutrino beams necessary to elucidate the physics of flavor at a neutrino factory and to provide lepton-antilepton collisions at energies of up to several TeV at a muon collider. The international Muon Ionization Cooling Experiment (MICE aims to demonstrate ionization cooling, the technique by which it is proposed to reduce the phase-space volume occupied by the muon beam at such facilities. In an ionization-cooling channel, the muon beam passes through a material in which it loses energy. The energy lost is then replaced using rf cavities. The combined effect of energy loss and reacceleration is to reduce the transverse emittance of the beam (transverse cooling. A major revision of the scope of the project was carried out over the summer of 2014. The revised experiment can deliver a demonstration of ionization cooling. The design of the cooling demonstration experiment will be described together with its predicted cooling performance.

  13. ATMOSPHERIC-PRESSURE-IONIZATION MASS-SPECTROMETRY .1. INSTRUMENTATION AND IONIZATION TECHNIQUES

    NARCIS (Netherlands)

    BRUINS, AP

    1994-01-01

    Mass spectrometer ion sources are normally located inside a high-vacuum envelope. Such low-pressure ion sources can make use of a range of different ionization methods and are in routine use in analytical mass spectrometers. An ion source operating at atmospheric pressure is better suited, and may b

  14. Exploration of the Dissociative Recombination following DNA ionization to DNA+ due to ionizing radiation

    Science.gov (United States)

    Strom, Richard A.; Zimmerly, Andrew T.; Andrianarijaona, Vola M.

    2014-05-01

    It is known that ionizing radiation generates low-energy secondary electrons, which may interact with the surrounding area, including biomolecules, such as triggering DNA single strand and double strand breaks as demonstrated by Sanche and coworkers (Radiat. Res. 157, 227(2002)). The bio-effects of low-energy electrons are currently a topic of high interest. Most of the studies are dedicated to dissociative electron attachments; however, the area is still mostly unexplored and still not well understood. We are computationally investigating the effect of ionizing radiation on DNA, such as its ionization to DNA+. More specifically, we are exploring the possibility of the dissociative recombination of the temporary DNA+ with one of the low-energy secondary electrons, produced by the ionizing radiation, to be another process of DNA strand breaks. Our preliminary results, which are performed with the binaries of ORCA, will be presented. Authors wish to give special thanks to Pacific Union College Student Senate in Angwin, California, for their financial support.

  15. Droplet dynamics and ionization mechanisms in desorption electrospray ionization mass spectrometry.

    Science.gov (United States)

    Venter, Andre; Sojka, Paul E; Cooks, R Graham

    2006-12-15

    A droplet pickup and other mechanisms have been suggested for the ionization of biomolecules like peptides and proteins by desorption electrospray ionization. To verify this hypothesis phase Doppler particle analysis was used to study the sizes and velocities of droplets involved in DESI. It was found that impacting droplets typically have velocities of 120 m/s and average diameters of 2-4 microm. Small differences in sprayer construction influence the operating conditions at which droplets of these dimensions are produced. Under these conditions, the kinetic energy per impacting water molecule is less than 0.6 meV and sputtering through momentum transfer during collisions or ionization by other electronic processes is unlikely. Droplets arrive at the surface with velocities well below the speed of sound in common materials, thereby excluding the possibility of ionization by shockwave formation. Some droplets appear to roll along the surface, increasing contact time and presumably the amount of material that is taken up into droplets during conditions typical of the DESI experiment.

  16. Study of ionization process of matrix molecules in matrix-assisted laser desorption ionization

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Kazumasa; Sato, Asami; Hashimoto, Kenro; Fujino, Tatsuya, E-mail: fujino@tmu.ac.jp

    2013-06-20

    Highlights: ► Proton transfer and adduction reaction of matrix in MALDI were studied. ► Hydroxyl group forming intramolecular hydrogen bond was related to the ionization. ► Intramolecular proton transfer in the electronic excited state was the initial step. ► Non-volatile analytes stabilized protonated matrix in the ground state. ► A possible mechanism, “analyte support mechanism”, has been proposed. - Abstract: Proton transfer and adduction reaction of matrix molecules in matrix-assisted laser desorption ionization were studied. By using 2,4,6-trihydroxyacetophenone (THAP), 2,5-dihydroxybenzoic acid (DHBA), and their related compounds in which the position of a hydroxyl group is different, it was clarified that a hydroxyl group forming an intramolecular hydrogen bond is related to the ionization of matrix molecules. Intramolecular proton transfer in the electronic excited state of the matrix and subsequent proton adduction from a surrounding solvent to the charge-separated matrix are the initial steps for the ionization of matrix molecules. Nanosecond pump–probe NIR–UV mass spectrometry confirmed that the existence of analyte molecules having large dipole moment in their structures is necessary for the stabilization of [matrix + H]{sup +} in the electronic ground state.

  17. Design of a fifth generation air superiority fighter

    Science.gov (United States)

    Atique, Md. Saifuddin Ahmed; Barman, Shuvrodeb; Nafi, Asif Shahriar; Bellah, Masum; Salam, Md. Abdus

    2016-07-01

    Air Superiority Fighter is considered to be an effective dogfighter which is stealthy & highly maneuverable to surprise enemy along with improve survivability against the missile fire. This new generation fighter aircraft requires fantastic aerodynamics design, low wing loading (W/S), high thrust to weight ratio (T/W) with super cruise ability. Conceptual design is the first step to design an aircraft. In this paper conceptual design of an Air Superiority Fighter Aircraft is proposed to carry 1 crew member (pilot) that can fly at maximum Mach No of 2.3 covering a range of 1500 km with maximum ceiling of 61,000 ft. Payload capacity of this proposed aircraft is 6000 lb that covers two advanced missiles & one advanced gun. The Air Superiority Fighter Aircraft was designed to undertake all the following missions like: combat air petrol, air to air combat, maritime attack, close air support, suppression, destruction of enemy air defense and reconnaissance.

  18. Temporal Bone Fracture Causing Superior Semicircular Canal Dehiscence

    Directory of Open Access Journals (Sweden)

    Kevin A. Peng

    2014-01-01

    Full Text Available Importance. Superior semicircular canal dehiscence (SCD is a third window lesion of the inner ear causing symptoms of vertigo, autophony, tinnitus, and hearing loss. A “two-hit” hypothesis has traditionally been proposed, whereby thinly developed bone overlying the superior canal is disrupted by a sudden change in intracranial pressure. Although the symptoms of SCD may be precipitated by head injury, no previous reports have described a temporal bone fracture directly causing SCD. Observations. Two patients sustained temporal bone fractures after closed head trauma, and developed unilateral otologic symptoms consistent with SCD. In each instance, computed tomography imaging revealed fractures extending through the bony roof of the superior semicircular canal. Conclusions and Relevance. Temporal bone fractures, which are largely treated nonoperatively, have not previously been reported to cause SCD. As it is a potentially treatable entity, SCD resulting from temporal bone fracture must be recognized as a possibility and diagnosed promptly if present.

  19. Partial anomalous pulmonary venous connection to the superior vena cava.

    Science.gov (United States)

    Aramendi, José I; Rey, Estibaliz; Hamzeh, Gadah; Crespo, Alejandro; Luis, Maite; Voces, Roberto

    2011-04-01

    We describe the surgical technique of reimplantation of the right superior pulmonary vein into the left atrium in 2 patients with partial anomalous pulmonary venous connection to the superior vena cava without atrial septal defect. A right axillary minithoracotomy is done through the fourth intercostal space. The pulmonary vein is detached from its origin in the superior vena cava. This is sutured with 6-0 reabsorbable polydioxanone suture (Ethicon, Somerville, NJ). A lateral clamp is applied to the left atrium, and the pulmonary vein is reimplanted. The patient is extubated in the operating room. Neither cardiopulmonary bypass nor blood transfusion was required. It is simple, safe, and reproducible. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Isolated abscess in superior rectus muscle in a child

    Directory of Open Access Journals (Sweden)

    Sushank Ashok Bhalerao

    2015-01-01

    Full Text Available Pyomyositis is a primary bacterial infection of striated muscles nearly always caused by Staphylococcus aureus. Development of the intramuscular abscess involving the extra-ocular muscles (EOMs remains an extremely rare process. We herein present a case of isolated EOM pyomyositis involving superior rectus muscle in a 2-year male child who was referred with complaints of swelling in left eye (LE and inability to open LE since last 1-month. Orbital computed tomography (CT scan showed a well-defined, hypo-dense, peripheral rim-enhancing lesion in relation to left superior rectus muscle suggestive of left superior rectus abscess. The abscess was drained through skin approach. We concluded that pyomyositis of EOM should be considered in any patient presenting with acute onset of orbital inflammation and characteristic CT or magnetic resonance imaging features. Management consists of incision and drainage coupled with antibiotic therapy.