WorldWideScience

Sample records for superior imaging capabilities

  1. Magnetic resonance imaging evaluation of meniscoid superior labrum: normal variant or superior labral tear

    Directory of Open Access Journals (Sweden)

    Marcelo Novelino Simão

    Full Text Available Abstract Objective: The objective of this study was to determine the incidence of a "meniscoid" superior labrum. Materials and Methods: This was a retrospective analysis of 582 magnetic resonance imaging examinations of shoulders. Of those 582 examinations, 110 were excluded, for a variety of reasons, and the final analysis therefore included 472 cases. Consensus readings were performed by three musculoskeletal radiologists using specific criteria to diagnose meniscoid labra. Results: A meniscoid superior labrum was identified in 48 (10.2% of the 472 cases evaluated. Arthroscopic proof was available in 21 cases (43.8%. In 10 (47.6% of those 21 cases, the operative report did not include the mention a superior labral tear, thus suggesting the presence of a meniscoid labrum. In only one of those cases were there specific comments about a mobile superior labrum (i.e., meniscoid labrum. In the remaining 11 (52.4%, surgical correlation demonstrated superior labral tears. Conclusion: A meniscoid superior labrum is not an infrequent finding. Depending upon assumptions and the requirement of surgical proof, the prevalence of a meniscoid superior labrum in this study was between 2.1% (surgically proven and 4.8% (projected. However, superior labral tears are just as common and are often confused with meniscoid labra.

  2. Total variation superiorized conjugate gradient method for image reconstruction

    Science.gov (United States)

    Zibetti, Marcelo V. W.; Lin, Chuan; Herman, Gabor T.

    2018-03-01

    The conjugate gradient (CG) method is commonly used for the relatively-rapid solution of least squares problems. In image reconstruction, the problem can be ill-posed and also contaminated by noise; due to this, approaches such as regularization should be utilized. Total variation (TV) is a useful regularization penalty, frequently utilized in image reconstruction for generating images with sharp edges. When a non-quadratic norm is selected for regularization, as is the case for TV, then it is no longer possible to use CG. Non-linear CG is an alternative, but it does not share the efficiency that CG shows with least squares and methods such as fast iterative shrinkage-thresholding algorithms (FISTA) are preferred for problems with TV norm. A different approach to including prior information is superiorization. In this paper it is shown that the conjugate gradient method can be superiorized. Five different CG variants are proposed, including preconditioned CG. The CG methods superiorized by the total variation norm are presented and their performance in image reconstruction is demonstrated. It is illustrated that some of the proposed variants of the superiorized CG method can produce reconstructions of superior quality to those produced by FISTA and in less computational time, due to the speed of the original CG for least squares problems. In the Appendix we examine the behavior of one of the superiorized CG methods (we call it S-CG); one of its input parameters is a positive number ɛ. It is proved that, for any given ɛ that is greater than the half-squared-residual for the least squares solution, S-CG terminates in a finite number of steps with an output for which the half-squared-residual is less than or equal to ɛ. Importantly, it is also the case that the output will have a lower value of TV than what would be provided by unsuperiorized CG for the same value ɛ of the half-squared residual.

  3. Magnetic resonance imaging in congenital superior oblique palsy

    International Nuclear Information System (INIS)

    Sato, Miho; Kondo, Nagako; Awaya, Shinobu; Nomura, Hideki; Yagasaki, Teiji.

    1996-01-01

    MRI examinations were carried out on the defined congenital superior oblique palsy in order to distinguish the congenital and acquired palsies. Subjects were 19 patients diagnosed as congenital and their MRI images of 3 or 5 mm-thick coronary slice were taken. The volume of the oblique muscle was calculated from the images and a comparison was made between the diseased and healthy normal sides. The oblique muscle volume at the diseased side was found reduced in most of congenital superior oblique palsy patients. The reduction was observed even at childhood and was thus considered to be a malformation. Further, it is conceivable that the palsy could be caused by the abnormality in the central nervous system as well as by the present anatomical abnormality. (K.H.)

  4. Computed tomography imaging for superior semicircular canal dehiscence syndrome

    International Nuclear Information System (INIS)

    Dobeli, Karen

    2006-01-01

    Superior semicircular canal dehiscence is a newly described syndrome of sound and/or pressure induced vertigo. Computed tomography (CT) imaging plays an important role in confirmation of a defect in the bone overlying the canal. A high resolution CT technique utilising 0.5 mm or thinner slices and multi-planar reconstructions parallel to the superior semicircular canal is required. Placement of a histogram over a suspected defect can assist CT diagnosis

  5. Imaging capabilities of germanium gamma cameras

    International Nuclear Information System (INIS)

    Steidley, J.W.

    1977-01-01

    Quantitative methods of analysis based on the use of a computer simulation were developed and used to investigate the imaging capabilities of germanium gamma cameras. The main advantage of the computer simulation is that the inherent unknowns of clinical imaging procedures are removed from the investigation. The effects of patient scattered radiation were incorporated using a mathematical LSF model which was empirically developed and experimentally verified. Image modifying effects of patient motion, spatial distortions, and count rate capabilities were also included in the model. Spatial domain and frequency domain modeling techniques were developed and used in the simulation as required. The imaging capabilities of gamma cameras were assessed using low contrast lesion source distributions. The results showed that an improvement in energy resolution from 10% to 2% offers significant clinical advantages in terms of improved contrast, increased detectability, and reduced patient dose. The improvements are of greatest significance for small lesions at low contrast. The results of the computer simulation were also used to compare a design of a hypothetical germanium gamma camera with a state-of-the-art scintillation camera. The computer model performed a parametric analysis of the interrelated effects of inherent and technological limitations of gamma camera imaging. In particular, the trade-off between collimator resolution and collimator efficiency for detection of a given low contrast lesion was directly addressed. This trade-off is an inherent limitation of both gamma cameras. The image degrading effects of patient motion, camera spatial distortions, and low count rate were shown to modify the improvements due to better energy resolution. Thus, based on this research, the continued development of germanium cameras to the point of clinical demonstration is recommended

  6. Review of fluorescence guided surgery systems: identification of key performance capabilities beyond indocyanine green imaging

    Science.gov (United States)

    DSouza, Alisha V.; Lin, Huiyun; Henderson, Eric R.; Samkoe, Kimberley S.; Pogue, Brian W.

    2016-01-01

    Abstract. There is growing interest in using fluorescence imaging instruments to guide surgery, and the leading options for open-field imaging are reviewed here. While the clinical fluorescence-guided surgery (FGS) field has been focused predominantly on indocyanine green (ICG) imaging, there is accelerated development of more specific molecular tracers. These agents should help advance new indications for which FGS presents a paradigm shift in how molecular information is provided for resection decisions. There has been a steady growth in commercially marketed FGS systems, each with their own differentiated performance characteristics and specifications. A set of desirable criteria is presented to guide the evaluation of instruments, including: (i) real-time overlay of white-light and fluorescence images, (ii) operation within ambient room lighting, (iii) nanomolar-level sensitivity, (iv) quantitative capabilities, (v) simultaneous multiple fluorophore imaging, and (vi) ergonomic utility for open surgery. In this review, United States Food and Drug Administration 510(k) cleared commercial systems and some leading premarket FGS research systems were evaluated to illustrate the continual increase in this performance feature base. Generally, the systems designed for ICG-only imaging have sufficient sensitivity to ICG, but a fraction of the other desired features listed above, with both lower sensitivity and dynamic range. In comparison, the emerging research systems targeted for use with molecular agents have unique capabilities that will be essential for successful clinical imaging studies with low-concentration agents or where superior rejection of ambient light is needed. There is no perfect imaging system, but the feature differences among them are important differentiators in their utility, as outlined in the data and tables here. PMID:27533438

  7. Review of fluorescence guided surgery systems: identification of key performance capabilities beyond indocyanine green imaging

    Science.gov (United States)

    DSouza, Alisha V.; Lin, Huiyun; Henderson, Eric R.; Samkoe, Kimberley S.; Pogue, Brian W.

    2016-08-01

    There is growing interest in using fluorescence imaging instruments to guide surgery, and the leading options for open-field imaging are reviewed here. While the clinical fluorescence-guided surgery (FGS) field has been focused predominantly on indocyanine green (ICG) imaging, there is accelerated development of more specific molecular tracers. These agents should help advance new indications for which FGS presents a paradigm shift in how molecular information is provided for resection decisions. There has been a steady growth in commercially marketed FGS systems, each with their own differentiated performance characteristics and specifications. A set of desirable criteria is presented to guide the evaluation of instruments, including: (i) real-time overlay of white-light and fluorescence images, (ii) operation within ambient room lighting, (iii) nanomolar-level sensitivity, (iv) quantitative capabilities, (v) simultaneous multiple fluorophore imaging, and (vi) ergonomic utility for open surgery. In this review, United States Food and Drug Administration 510(k) cleared commercial systems and some leading premarket FGS research systems were evaluated to illustrate the continual increase in this performance feature base. Generally, the systems designed for ICG-only imaging have sufficient sensitivity to ICG, but a fraction of the other desired features listed above, with both lower sensitivity and dynamic range. In comparison, the emerging research systems targeted for use with molecular agents have unique capabilities that will be essential for successful clinical imaging studies with low-concentration agents or where superior rejection of ambient light is needed. There is no perfect imaging system, but the feature differences among them are important differentiators in their utility, as outlined in the data and tables here.

  8. Superiorized algorithm for reconstruction of CT images from sparse-view and limited-angle polyenergetic data

    Science.gov (United States)

    Humphries, T.; Winn, J.; Faridani, A.

    2017-08-01

    Recent work in CT image reconstruction has seen increasing interest in the use of total variation (TV) and related penalties to regularize problems involving reconstruction from undersampled or incomplete data. Superiorization is a recently proposed heuristic which provides an automatic procedure to ‘superiorize’ an iterative image reconstruction algorithm with respect to a chosen objective function, such as TV. Under certain conditions, the superiorized algorithm is guaranteed to find a solution that is as satisfactory as any found by the original algorithm with respect to satisfying the constraints of the problem; this solution is also expected to be superior with respect to the chosen objective. Most work on superiorization has used reconstruction algorithms which assume a linear measurement model, which in the case of CT corresponds to data generated from a monoenergetic x-ray beam. Many CT systems generate x-rays from a polyenergetic spectrum, however, in which the measured data represent an integral of object attenuation over all energies in the spectrum. This inconsistency with the linear model produces the well-known beam hardening artifacts, which impair analysis of CT images. In this work we superiorize an iterative algorithm for reconstruction from polyenergetic data, using both TV and an anisotropic TV (ATV) penalty. We apply the superiorized algorithm in numerical phantom experiments modeling both sparse-view and limited-angle scenarios. In our experiments, the superiorized algorithm successfully finds solutions which are as constraints-compatible as those found by the original algorithm, with significantly reduced TV and ATV values. The superiorized algorithm thus produces images with greatly reduced sparse-view and limited angle artifacts, which are also largely free of the beam hardening artifacts that would be present if a superiorized version of a monoenergetic algorithm were used.

  9. X-ray micro-tomography system for small-animal imaging with zoom-in imaging capability

    International Nuclear Information System (INIS)

    Chun, In Kon; Cho, Myung Hye; Lee, Sang Chul; Cho, Min Hyoung; Lee, Soo Yeol

    2004-01-01

    Since a micro-tomography system capable of μm-resolution imaging cannot be used for whole-body imaging of a small laboratory animal without sacrificing its spatial resolution, it is desirable for a micro-tomography system to have local imaging capability. In this paper, we introduce an x-ray micro-tomography system capable of high-resolution imaging of a local region inside a small animal. By combining two kinds of projection data, one from a full field-of-view (FOV) scan of the whole body and the other from a limited FOV scan of the region of interest (ROI), we have obtained zoomed-in images of the ROI without any contrast anomalies commonly appearing in conventional local tomography. For experimental verification of the zoom-in imaging capability, we have integrated a micro-tomography system using a micro-focus x-ray source, a 1248 x 1248 flat-panel x-ray detector, and a precision scan mechanism. The mismatches between the two projection data caused by misalignments of the scan mechanism have been estimated with a calibration phantom, and the mismatch effects have been compensated in the image reconstruction procedure. Zoom-in imaging results of bony tissues with a spatial resolution of 10 lp mm -1 suggest that zoom-in micro-tomography can be greatly used for high-resolution imaging of a local region in small-animal studies

  10. The optimal monochromatic spectral computed tomographic imaging plus adaptive statistical iterative reconstruction algorithm can improve the superior mesenteric vessel image quality

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Xiao-Ping; Zuo, Zi-Wei; Xu, Ying-Jin; Wang, Jia-Ning [CT/MRI room, Affiliated Hospital of Hebei University, Baoding, Hebei, 071000 (China); Liu, Huai-Jun, E-mail: hebeiliu@outlook.com [Department of Medical Imaging, The Second Hospital of Hebei Medical University, Shijiazhuang, Hebei, 050000 (China); Liang, Guang-Lu [CT/MRI room, Affiliated Hospital of Hebei University, Baoding, Hebei, 071000 (China); Gao, Bu-Lang, E-mail: browngao@163.com [Department of Medical Research, Shijiazhuang First Hospital, Shijiazhuang, Hebei, 050011 (China)

    2017-04-15

    Objective: To investigate the effect of the optimal monochromatic spectral computed tomography (CT) plus adaptive statistical iterative reconstruction on the improvement of the image quality of the superior mesenteric artery and vein. Materials and methods: The gemstone spectral CT angiographic data of 25 patients were reconstructed in the following three groups: 70 KeV, the optimal monochromatic imaging, and the optimal monochromatic plus 40%iterative reconstruction mode. The CT value, image noises (IN), background CT value and noises, contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR) and image scores of the vessels and surrounding tissues were analyzed. Results: In the 70 KeV, the optimal monochromatic and the optimal monochromatic images plus 40% iterative reconstruction group, the mean scores of image quality were 3.86, 4.24 and 4.25 for the superior mesenteric artery and 3.46, 3.78 and 3.81 for the superior mesenteric vein, respectively. The image quality scores for the optimal monochromatic and the optimal monochromatic plus 40% iterative reconstruction groups were significantly greater than for the 70 KeV group (P < 0.05). The vascular CT value, image noise, background noise, CNR and SNR were significantly (P < 0.001) greater in the optimal monochromatic and the optimal monochromatic images plus 40% iterative reconstruction group than in the 70 KeV group. The optimal monochromatic plus 40% iterative reconstruction group had significantly (P < 0.05) lower image and background noise but higher CNR and SNR than the other two groups. Conclusion: The optimal monochromatic imaging combined with 40% iterative reconstruction using low-contrast agent dosage and low injection rate can significantly improve the image quality of the superior mesenteric artery and vein.

  11. Superior supercapacitors based on nitrogen and sulfur co-doped hierarchical porous carbon: Excellent rate capability and cycle stability

    Science.gov (United States)

    Zhang, Deyi; Han, Mei; Wang, Bing; Li, Yubing; Lei, Longyan; Wang, Kunjie; Wang, Yi; Zhang, Liang; Feng, Huixia

    2017-08-01

    Vastly improving the charge storage capability of supercapacitors without sacrificing their high power density and cycle performance would bring bright application prospect. Herein, we report a nitrogen and sulfur co-doped hierarchical porous carbon (NSHPC) with very superior capacitance performance fabricated by KOH activation of nitrogen and sulfur co-doped ordered mesoporous carbon (NSOMC). A high electrochemical double-layer (EDL) capacitance of 351 F g-1 was observed for the reported NSHPC electrodes, and the capacitance remains at 288 F g-1 even under a large current density of 20 A g-1. Besides the high specific capacitance and outstanding rate capability, symmetrical supercapacitor cell based on the NSHPC electrodes also exhibits an excellent cycling performance with 95.61% capacitance retention after 5000 times charge/discharge cycles. The large surface area caused by KOH activation (2056 m2 g-1) and high utilized surface area owing to the ideal micro/mesopores ratio (2.88), large micropores diameter (1.38 nm) and short opened micropores structure as well as the enhanced surface wettability induced by N and S heteroatoms doping and improved conductivity induced by KOH activation was found to be responsible for the very superior capacitance performance.

  12. Optimization of CMOS image sensor utilizing variable temporal multisampling partial transfer technique to achieve full-frame high dynamic range with superior low light and stop motion capability

    Science.gov (United States)

    Kabir, Salman; Smith, Craig; Armstrong, Frank; Barnard, Gerrit; Schneider, Alex; Guidash, Michael; Vogelsang, Thomas; Endsley, Jay

    2018-03-01

    Differential binary pixel technology is a threshold-based timing, readout, and image reconstruction method that utilizes the subframe partial charge transfer technique in a standard four-transistor (4T) pixel CMOS image sensor to achieve a high dynamic range video with stop motion. This technology improves low light signal-to-noise ratio (SNR) by up to 21 dB. The method is verified in silicon using a Taiwan Semiconductor Manufacturing Company's 65 nm 1.1 μm pixel technology 1 megapixel test chip array and is compared with a traditional 4 × oversampling technique using full charge transfer to show low light SNR superiority of the presented technology.

  13. Persistent left superior vena cava with absent right superior vena cava: image findings

    International Nuclear Information System (INIS)

    Araujo Junior, Cyrillo Rodrigues de; Carvalho, Tarcisio Nunes; Fraguas Filho, Sergio Roberto; Costa, Marlos Augusto Bitencourt; Jacob, Beatriz Mahmud; Machado, Marcio Martins; Teixeira, Kim-Ir-Sen Santos; Ximenes, Carlos Alberto

    2003-01-01

    Persistent left superior vena cava absent right superior vena cava is a rare anomaly, with less than 150 cases reported in the literature. Congenitally persistent left superior vena cava is the most common variant of systemic venous return to the heart, resulting embryologically from failure of the left anterior cardinal vein to become obliterated. Its incidence varies from 0.3% in patients with otherwise normal heart to 4.3% in patients with congenital heart disease. In the majority of the patients, a right superior vena cava is present as well, but rarely the right anterior cardinal vein degenerates resulting in the absence of the normal right superior vena cava. The blood from the right side is carried by the persistent left superior vena cava to the right atrium through the coronary sinus. We report the case of a patient with a persistent left superior vena cava and absence of right superior vena cava identified by chance during a chest radiograph and computed tomography examination for investigation of chronic pulmonary obstructive disease. The patient had no congenital heart disease and the blood from the right side was drained by the persistent left superior vena cava into the right atrium through the coronary sinus. (author)

  14. Superior Generalization Capability of Hardware-Learing Algorithm Developed for Self-Learning Neuron-MOS Neural Networks

    Science.gov (United States)

    Kondo, Shuhei; Shibata, Tadashi; Ohmi, Tadahiro

    1995-02-01

    We have investigated the learning performance of the hardware backpropagation (HBP) algorithm, a hardware-oriented learning algorithm developed for the self-learning architecture of neural networks constructed using neuron MOS (metal-oxide-semiconductor) transistors. The solution to finding a mirror symmetry axis in a 4×4 binary pixel array was tested by computer simulation based on the HBP algorithm. Despite the inherent restrictions imposed on the hardware-learning algorithm, HBP exhibits equivalent learning performance to that of the original backpropagation (BP) algorithm when all the pertinent parameters are optimized. Very importantly, we have found that HBP has a superior generalization capability over BP; namely, HBP exhibits higher performance in solving problems that the network has not yet learnt.

  15. Moving image compression and generalization capability of constructive neural networks

    Science.gov (United States)

    Ma, Liying; Khorasani, Khashayar

    2001-03-01

    To date numerous techniques have been proposed to compress digital images to ease their storage and transmission over communication channels. Recently, a number of image compression algorithms using Neural Networks NNs have been developed. Particularly, several constructive feed-forward neural networks FNNs have been proposed by researchers for image compression, and promising results have been reported. At the previous SPIE AeroSense conference 2000, we proposed to use a constructive One-Hidden-Layer Feedforward Neural Network OHL-FNN for compressing digital images. In this paper, we first investigate the generalization capability of the proposed OHL-FNN in the presence of additive noise for network training and/ or generalization. Extensive experimental results for different scenarios are presented. It is revealed that the constructive OHL-FNN is not as robust to additive noise in input image as expected. Next, the constructive OHL-FNN is applied to moving images, video sequences. The first, or other specified frame in a moving image sequence is used to train the network. The remaining moving images that follow are then generalized/compressed by this trained network. Three types of correlation-like criteria measuring the similarity of any two images are introduced. The relationship between the generalization capability of the constructed net and the similarity of images is investigated in some detail. It is shown that the constructive OHL-FNN is promising even for changing images such as those extracted from a football game.

  16. New and Emerging Satellite Imaging Capabilities in Support of Safeguards

    International Nuclear Information System (INIS)

    Johnson, M.; Paquette, J.P.; Spyropoulos, N.; Rainville, L.; Schichor, P.; Hong, M.

    2015-01-01

    This abstract is focused on new and emerging commercial satellite imagery (CSI) capabilities. For more than a decade, experienced imagery analysts have been exploiting and analyzing CSI in support of the Department of Safeguards. As the remote sensing industry continues to evolve, additional CSI imagery types are becoming available that could enhance our ability to evaluate and verify States' declarations and to investigate the possible presence of undeclared activities. A newly available and promising CSI capability that may have a Safeguards application is Full Motion Video (FMV) imagery collection from satellites. For quite some time, FMV imagery has been collected from airborne platforms, but now FMV sensors are being deployed into space. Like its airborne counterpart, satellite FMV imagery could provide analysts with a great deal of information, including insight into the operational status of facilities and patterns of activity. From a Safeguards perspective, FMV imagery could help the Agency in the evaluation and verification of States' declared facilities and activities. There are advantages of FMV imaging capabilities that cannot be duplicated with other CSI capabilities, including the ability to loiter over areas of interest and the potential to revisit sites multiple times per day. Additional sensor capabilities applicable to the Safeguards mission include, but are not limited to, the following sensors: · Thermal Infrared imaging sensors will be launched in late 2014 to monitor operational status, e.g., heat from a transformer. · High resolution ShortWave Infrared sensors able to characterize materials that could support verification of Additional Protocol declarations under Article 2.a(v). · Unmanned Aerial Vehicles with individual sensors or specific sensor combinations. The Safeguards Symposium provides a forum to showcase and demonstrate safeguards applications for these emerging satellite imaging capabilities. (author)

  17. Positron imaging system with improved count rate and tomographic capability

    International Nuclear Information System (INIS)

    Muehllehner, G.; Buchin, M.P.

    1980-01-01

    Improvements to a positron camera imaging system are described. A pair of Angear-type scintillation cameras serve as the detectors, each camera being positioned on opposite sides of the organ of interest. Pulse shaping circuits reduce the pulse duration below 900 nanoseconds and the integration time below 500 noneseconds, improving the count rate capability and the counting statistics of the system and thus the image quality and processing speed. The invention also provides means for rotating the opposed camera heads about an axis which passes through the organ of interest. The cameras do not use collimators, and are capable of accepting radiation travelling in planes not perpendicular to the scintillation crystals. (LL)

  18. Breast varices: imaging findings of an unusual presentation of collateral pathways in superior vena caval syndrome

    International Nuclear Information System (INIS)

    Oezdemir, Ayseguel; Ilgit, Erhan T.; Konus, Oeznur L.; Cetin, Meltem; Oezsunar, Yelda

    2000-01-01

    Imaging findings are presented of an unusual pathway of collateral circulation consisting of bilateral and diffuse dilated breast veins from a patient with long standing superior vena caval syndrome. The main importance of this case is the extent of the collateral development through the breast veins, serving as the major pathway of collateral circulation. Identification of this unusual collateral development, which resembles breast varices, was performed with contrast-enhanced chest CT scans, digital subtraction venography, color Doppler ultrasonography, and mammographic studies. Collateral development was secondary to a long segment idiopathic venous occlusion involving bilateral subclavian and brachiocephalic veins as well as vena cava superior. We conclude that dilated breast veins when detected on any imaging modality should raise the suspicion of central venous obstruction

  19. Incidence of dehiscence of the bony roof of the superior semicircular canal by CT imaging

    International Nuclear Information System (INIS)

    Watanabe, Akira

    2003-01-01

    Dehiscence of the bony roof of the superior semicircular canal (SSCC) is rare, but it has been recognized by otologists since Minor et al first described superior canal dehiscence syndrome (SCDS). In this study, dehiscence of the bony roof of SSCC was incidentally detected in three patients with benign paroxysmal positional vertigo out of 49 serial patients with vertigo and dizziness by multi-slice computed tomography. Although detection of dehiscence of the SSCC by ultra-high-resolution CT imaging of the temporal bones has been required for a diagnosis of SCDS, this study showed that dehiscence of the bony roof of the SSCC can be an incidental finding and therefore is not specific for SCDS. (author)

  20. Advances in U.S. Land Imaging Capabilities

    Science.gov (United States)

    Stryker, T. S.

    2017-12-01

    Advancements in Earth observations, cloud computing, and data science are improving everyday life. Information from land-imaging satellites, such as the U.S. Landsat system, helps us to better understand the changing landscapes where we live, work, and play. This understanding builds capacity for improved decision-making about our lands, waters, and resources, driving economic growth, protecting lives and property, and safeguarding the environment. The USGS is fostering the use of land remote sensing technology to meet local, national, and global challenges. A key dimension to meeting these challenges is the full, free, and open provision of land remote sensing observations for both public and private sector applications. To achieve maximum impact, these data must also be easily discoverable, accessible, and usable. The presenter will describe the USGS Land Remote Sensing Program's current capabilities and future plans to collect and deliver land remote sensing information for societal benefit. He will discuss these capabilities in the context of national plans and policies, domestic partnerships, and international collaboration. The presenter will conclude with examples of how Landsat data is being used on a daily basis to improve lives and livelihoods.

  1. Veia cava superior esquerda anômala com ausência de veia cava superior direita: achados de imagem Persistent left superior vena cava with absent right superior vena cava: image findings

    Directory of Open Access Journals (Sweden)

    Cyrillo Rodrigues de Araújo Júnior

    2003-10-01

    Full Text Available A persistência da veia cava superior esquerda com ausência da veia cava superior direita é uma anomalia rara, com menos de 150 casos descritos na literatura. A não-obliteração e regressão da veia cardinal anterior esquerda durante o desenvolvimento embriológico promove uma variação sistêmica de retorno venoso ao coração, com persistência da veia cava superior esquerda. Sua incidência varia de 0,3% em pacientes sem alterações cardíacas congênitas concomitantes a 4,3% naqueles com cardiopatias. Na maioria das vezes coexiste a veia cava superior direita, porém se houver regressão e degeneração da veia cardinal anterior direita, implicará a sua ausência e a drenagem venosa para o coração será feita pela veia cava superior esquerda ao átrio direito, através do seio coronariano. Mostramos um caso de um paciente submetido a radiografia de tórax e tomografia computadorizada para avaliação de doença pulmonar obstrutiva crônica, tendo como achado a persistência da veia cava superior esquerda com ausência da direita, sem qualquer cardiopatia associada e com a drenagem cardíaca sendo feita, através do seio coronariano, para o átrio direito.Persistent left superior vena cava with absent right superior vena cava is a rare anomaly, with less than 150 cases reported in the literature. Congenitally persistent left superior vena cava is the most common variant of systemic venous return to the heart, resulting embryologically from failure of the left anterior cardinal vein to become obliterated. Its incidence varies from 0.3% in patients with otherwise normal heart to 4.3% in patients with congenital heart disease. In the majority of the patients, a right superior vena cava is present as well, but rarely the right anterior cardinal vein degenerates resulting in the absence of the normal right superior vena cava. The blood from the right side is carried by the persistent left superior vena cava to the right atrium through the

  2. Neural evidence for the use of digit-image mnemonic in a superior memorist: An fMRI study

    Directory of Open Access Journals (Sweden)

    Li-Jun eYin

    2015-03-01

    Full Text Available Some superior memorists demonstrated exceptional memory for reciting a large body of information. The underlying neural correlates, however, are seldom addressed. C.L., the current holder of Guinness World Record for reciting 67,890 digits in π, participated in this functional magnetic resonance imaging (fMRI study. Thirteen participants without any mnemonics training were included as controls. Our previous studies suggested that C.L. used a digit-image mnemonic in studying and recalling lists of digits, namely associating 2-digit groups of ‘00’ to ‘99’ with images and generating vivid stories out of them (Hu, Ericsson, Yang & Lu, 2009. Thus, 2-digit condition was included, with 1-digit numbers and letters as control conditions. We hypothesized that 2-digit condition in C.L. should elicit the strongest activity in the brain regions which are associated with his mnemonic. Functional MRI results revealed that bilateral frontal poles (FPs, BA10, left superior parietal lobule (SPL, left premotor cortex (PMC, and left dorsolateral prefrontal cortex (DLPFC, were more engaged in both the study and recall phase of 2-digit condition for C.L. relative to controls. Moreover, the left middle/inferior frontal gyri (M/IFG and intraparietal sulci (IPS were less engaged in the study phase of 2-digit condition for C.L. (vs. controls. These results suggested that C.L. relied more on brain regions that are associated with episodic memory other than verbal rehearsal while he used his mnemonic strategies. This study supported theoretical accounts of restructured cognitive mechanisms for the acquisition of superior memory performance.

  3. Building Alliance Capability: Management Techniques for Superior Alliance Performance

    NARCIS (Netherlands)

    J.A.J. Draulans (Johan); A-P. de Man (Ard-Pieter); H.W. Volberda (Henk)

    2003-01-01

    textabstractDespite the fact that they represent a growing element of business strategy, alliances between organisations quite often result in failure. This is partly due to the fact that firms have not built up adequate capabilities to manage alliances. Special management techniques have to be

  4. Musculoskeletal applications of magnetic resonance imaging: Council on Scientific Affairs

    International Nuclear Information System (INIS)

    Harms, S.E.; Fisher, C.F.; Fulmer, J.M.

    1989-01-01

    Magnetic resonance imaging provides superior contrast, resolution, and multiplanar imaging capability, allowing excellent definition of soft-tissue and bone marrow abnormalities. For these reasons, magnetic resonance imaging has become a major diagnostic imaging method for the evaluation of many musculoskeletal disorders. The applications of magnetic resonance imaging for musculoskeletal diagnosis are summarized and examples of common clinical situations are given. General guidelines are suggested for the musculoskeletal applications of magnetic resonance imaging

  5. Positron imaging system with improved count rate and tomographic capability

    International Nuclear Information System (INIS)

    1979-01-01

    A system with improved count rate capability for detecting the radioactive distribution of positron events within an organ of interest in a living subject is described. Objects of the invention include improving the scintillation crystal and pulse processing electronics, avoiding the limitations of collimators and provide an Arger camera positron imaging system that avoids the use of collimators. (U.K.)

  6. Building alliance capability : management techniques for superior alliance performance

    NARCIS (Netherlands)

    Draulans, J.; Man, de A.P.; Volberda, H.W.

    2003-01-01

    Despite the fact that they represent a growing element of business strategy, alliances between organisations quite often result in failure. This is partly due to the fact that firms have not built up adequate capabilities to manage alliances. Special management techniques have to be implemented in

  7. Calibration Efforts and Unique Capabilities of the HST Space Telescope Imaging Spectrograph

    Science.gov (United States)

    Monroe, TalaWanda R.; Proffitt, Charles R.; Welty, Daniel; Branton, Doug; Carlberg, Joleen K.; debes, John Henry; Lockwood, Sean; Riley, Allyssa; Sohn, Sangmo Tony; Sonnentrucker, Paule G.; Walborn, Nolan R.; Jedrzejewski, Robert I.

    2018-01-01

    The Space Telescope Imaging Spectrograph (STIS) continues to offer the astronomy community the ability to carry out innovative UV and optical spectroscopic and imaging studies, two decades after its deployment on the Hubble Space Telescope (HST). Most notably, STIS provides spectroscopy in the FUV and NUV, including high spectral resolution echelle modes, imaging in the FUV, optical spectroscopy, and coronagraphic capabilities. Additionally, spatial scanning on the CCD with the long-slits is now possible to enable very high S/N spectroscopic observations without saturation while mitigating telluric and fringing concerns in the far red and near-IR. This new mode may especially benefit the diffuse interstellar bands and exoplanet transiting communities. We present recent calibration efforts for the instrument, including work to optimize the calibration of the echelle spectroscopic modes by improving the flux agreement of overlapping spectral orders affected by changes in the grating blaze function since HST Servicing Mission 4. We also discuss considerations to maintain the wavelength precision of the spectroscopic modes, and the current capabilities of CCD spectroscopic spatial trails.

  8. Kinematic magnetic resonance imaging (MRI) of the normal shoulder: assessment of the shapes and signals of the superior and inferior labra with abductive movement using an open-type imager.

    OpenAIRE

    Togami, Izumi; Sasai, Nobuya; Tsunoda, Masatoshi; Sei, Tetsuro; Yabuki, Takayuki; Kitagawa, Takahiro; Mitani, Masahiko; Akaki, Shiro; Kuroda, Masahiro; Hiraki, Yoshio

    2001-01-01

    A preliminary study was conducted to evaluate the superior and inferior glenoid labra with abductive movement using an open-type MR unit in asymptomatic healthy volunteers. Both fast low angle shot (FLASH) and turbo spin echo (TSE) images were obtained to evaluate the shapes of both the superior and inferior labra, as well as to assess changes in signal at these sites. As the abduction angle was increased, the shape of the superior labrum changed from round or triangular to crescentic and a h...

  9. Controllable Electrochemical Synthesis of Copper Sulfides as Sodium-Ion Battery Anodes with Superior Rate Capability and Ultralong Cycle Life.

    Science.gov (United States)

    Li, Haomiao; Wang, Kangli; Cheng, Shijie; Jiang, Kai

    2018-03-07

    Sodium-ion batteries (SIBs) are prospective alternative to lithium-ion batteries for large-scale energy-storage applications, owing to the abundant resources of sodium. Metal sulfides are deemed to be promising anode materials for SIBs due to their low-cost and eco-friendliness. Herein, for the first time, series of copper sulfides (Cu 2 S, Cu 7 S 4 , and Cu 7 KS 4 ) are controllably synthesized via a facile electrochemical route in KCl-NaCl-Na 2 S molten salts. The as-prepared Cu 2 S with micron-sized flakes structure is first investigated as anode of SIBs, which delivers a capacity of 430 mAh g -1 with a high initial Coulombic efficiency of 84.9% at a current density of 100 mA g -1 . Moreover, the Cu 2 S anode demonstrates superior capability (337 mAh g -1 at 20 A g -1 , corresponding to 50 C) and ultralong cycle performance (88.2% of capacity retention after 5000 cycles at 5 A g -1 , corresponding to 0.0024% of fade rate per cycle). Meanwhile, the pseudocapacitance contribution and robust porous structure in situ formed during cycling endow the Cu 2 S anodes with outstanding rate capability and enhanced cyclic performance, which are revealed by kinetics analysis and ex situ characterization.

  10. Tin Oxide/Graphene Aerogel Nanocomposites Building Superior Rate Capability for Lithium Ion Batteries

    International Nuclear Information System (INIS)

    Fan, Linlin; Li, Xifei; Cui, Yanhua; Xu, Hui; Zhang, Xianfa; Xiong, Dongbin; Yan, Bo; Wang, Yufen; Li, Dejun

    2015-01-01

    Highlights: • The SnO 2 /GA nanocomposites were successfully synthesized via a hydrothermal method. • The performance of nanocomposite anodes highly depended on the hydrothermal time. • The 3-4 nm-sized SnO 2 /GAs showed enhanced cycling performance and rate performance. - Abstract: SnO 2 has attracted intense interest for use as an anode material for lithium ion batteries because of various advantages of the high theoretical capacity and low-cost. Unfortunately, SnO 2 anode material suffers from the huge volume change and poor electrical conductivity. In order to address these problems, in this work, SnO 2 /graphene aerogel composites have been successfully synthesized by a facile hydrothermal approach. 3-4 nm-sized SnO 2 nanoparticles are uniformly dispersed over graphene aerogels. Our results indicate that the hydrothermal reaction time highly affects the electrode performance of the anodes. The nanocomposite electrode with reaction time of 3 h shows increased electrochemical performance with high energy capacity, long cycle life, and superior rate capability. After 100 cycles, it can deliver a high discharge capacity of 662 mAh g −1 at 100 mA g −1 . At 500 mA g −1 , it can still yield a discharge capacity of 619.7 mAh g −1 after 723 cycles. The performance improvement can attribute to the graphene aerogel, which can suppress the aggregation of SnO 2 nanoparticles, enhance the conductivity of SnO 2 , and increase their structural stability during cycling. This study strongly demonstrates that the SnO 2 /graphene aerogel composite is a promising anode material building high performance lithium ion batteries

  11. Semiautomated volumetric response evaluation as an imaging biomarker in superior sulcus tumors

    International Nuclear Information System (INIS)

    Vos, C.G.; Paul, M.A.; Dahele, M.; Soernsen de Koste, J.R. van; Senan, S.; Bahce, I.; Smit, E.F.; Thunnissen, E.; Hartemink, K.J.

    2014-01-01

    Volumetric response to therapy has been suggested as a biomarker for patient-centered outcomes. The primary aim of this pilot study was to investigate whether the volumetric response to induction chemoradiotherapy was associated with pathological complete response (pCR) or survival in patients with superior sulcus tumors managed with trimodality therapy. The secondary aim was to evaluate a semiautomated method for serial volume assessment. In this retrospective study, treatment outcomes were obtained from a departmental database. The tumor was delineated on the computed tomography (CT) scan used for radiotherapy planning, which was typically performed during the first cycle of chemotherapy. These contours were transferred to the post-chemoradiotherapy diagnostic CT scan using deformable image registration (DIR) with/without manual editing. CT scans from 30 eligible patients were analyzed. Median follow-up was 51 months. Neither absolute nor relative reduction in tumor volume following chemoradiotherapy correlated with pCR or 2-year survival. The tumor volumes determined by DIR alone and DIR + manual editing correlated to a high degree (R 2 = 0.99, P < 0.01). Volumetric response to induction chemoradiotherapy was not correlated with pCR or survival in patients with superior sulcus tumors managed with trimodality therapy. DIR-based contour propagation merits further evaluation as a tool for serial volumetric assessment. (orig.)

  12. Superior Pattern Processing is the Essence of the Evolved Human Brain

    Directory of Open Access Journals (Sweden)

    Mark eMattson

    2014-08-01

    Full Text Available Humans have long pondered the nature of their mind/brain and, particularly why its capacities for reasoning, communication and abstract thought are far superior to other species, including closely related anthropoids. This article considers superior pattern processing (SPP as the fundamental basis of most, if not all, unique features of the human brain including intelligence, language, imagination, invention, and the belief in imaginary entities such as ghosts and gods. SPP involves the electrochemical, neuronal network-based, encoding, integration, and transfer to other individuals of perceived or mentally-fabricated patterns. During human evolution, pattern processing capabilities became increasingly sophisticated as the result of expansion of the cerebral cortex, particularly the prefrontal cortex and regions involved in processing of images. Specific patterns, real or imagined, are reinforced by emotional experiences, indoctrination and even psychedelic drugs. Impaired or dysregulated SPP is fundamental to cognitive and psychiatric disorders. A broader understanding of SPP mechanisms, and their roles in normal and abnormal function of the human brain, may enable the development of interventions that reduce irrational decisions and destructive behaviors.

  13. Commissioning and quality assurance of the x-ray volume imaging system of an image-guided radiotherapy capable linear accelerator

    International Nuclear Information System (INIS)

    Muralidhar, K.R.; Narayana Murthy, P.; Kumar, Rajneesh

    2008-01-01

    An Image-Guided Radiotherapy-capable linear accelerator (Elekta Synergy) was installed at our hospital, which is equipped with a kV x-ray volume imaging (XVI) system and electronic portal imaging device (iViewGT). The objective of this presentation is to describe the results of commissioning measurements carried out on the XVI facility to verify the manufacturer's specifications and also to evolve a QA schedule which can be used to test its performance routinely. The QA program consists of a series of tests (safety features, geometric accuracy, and image quality). These tests were found to be useful to assess the performance of the XVI system and also proved that XVI system is very suitable for image-guided high-precision radiation therapy. (author)

  14. Commissioning and quality assurance of the X-ray volume Imaging system of an image-guided radiotherapy capable linear accelerator

    Directory of Open Access Journals (Sweden)

    Muralidhar K

    2008-01-01

    Full Text Available An Image-Guided Radiotherapy-capable linear accelerator (Elekta Synergy was installed at our hospital, which is equipped with a kV x-ray volume imaging (XVI system and electronic portal imaging device (iViewGT. The objective of this presentation is to describe the results of commissioning measurements carried out on the XVI facility to verify the manufacturer′s specifications and also to evolve a QA schedule which can be used to test its performance routinely. The QA program consists of a series of tests (safety features, geometric accuracy, and image quality. These tests were found to be useful to assess the performance of the XVI system and also proved that XVI system is very suitable for image-guided high-precision radiation therapy.

  15. An ultra-low power CMOS image sensor with on-chip energy harvesting and power management capability.

    Science.gov (United States)

    Cevik, Ismail; Huang, Xiwei; Yu, Hao; Yan, Mei; Ay, Suat U

    2015-03-06

    An ultra-low power CMOS image sensor with on-chip energy harvesting and power management capability is introduced in this paper. The photodiode pixel array can not only capture images but also harvest solar energy. As such, the CMOS image sensor chip is able to switch between imaging and harvesting modes towards self-power operation. Moreover, an on-chip maximum power point tracking (MPPT)-based power management system (PMS) is designed for the dual-mode image sensor to further improve the energy efficiency. A new isolated P-well energy harvesting and imaging (EHI) pixel with very high fill factor is introduced. Several ultra-low power design techniques such as reset and select boosting techniques have been utilized to maintain a wide pixel dynamic range. The chip was designed and fabricated in a 1.8 V, 1P6M 0.18 µm CMOS process. Total power consumption of the imager is 6.53 µW for a 96 × 96 pixel array with 1 V supply and 5 fps frame rate. Up to 30 μW of power could be generated by the new EHI pixels. The PMS is capable of providing 3× the power required during imaging mode with 50% efficiency allowing energy autonomous operation with a 72.5% duty cycle.

  16. Small Firm Adaptive Capability, Competitive Strategy and Performance Outcomes: Competing Mediation vs Moderation Perspectives

    OpenAIRE

    Chryssochoidis, George; Dousios, Dimitrios; Tzokas, Nikolaos

    2016-01-01

    In small firms, adaptive capability exercises a handling grip on competitive strategy for superior performance primarily acting as a mediator and may offset, through attenuation, the adverse impact of limited resources. Besides exercising a handling grip on competitive strategy adaptive capability is more important than competitive strategy per se for superior performance. Adaptive capability simultaneously undertakes additional secondary roles reinforcing innovation competitive strategy for ...

  17. Image processing for the Advanced Radiographic Capability (ARC) at the National Ignition Facility

    Science.gov (United States)

    Leach, Richard R.; Awwal, Abdul A. S.; Lowe-Webb, Roger; Miller-Kamm, Victoria; Orth, Charles; Roberts, Randy; Wilhelmsen, Karl

    2016-09-01

    The Advance Radiographic Capability (ARC) at the National Ignition Facility (NIF) is a laser system that employs up to four petawatt (PW) lasers to produce a sequence of short-pulse kilo-Joule laser pulses with controllable delays that generate X-rays to provide backlighting for high-density internal confinement fusion (ICF) capsule targets. Multi-frame, hard-X-ray radiography of imploding NIF capsules is a capability which is critical to the success of NIF's missions. ARC is designed to employ up to eight backlighters with tens-of-picosecond temporal resolution, to record the dynamics and produce an X-ray "motion picture" of the compression and ignition of cryogenic deuterium-tritium targets. ARC will generate tens-of-picosecond temporal resolution during the critical phases of ICF shots. Additionally, ARC supports a variety of other high energy density experiments including fast ignition studies on NIF. The automated alignment image analysis algorithms use digital camera sensor images to direct ARC beams onto the tens-of-microns scale metal wires. This paper describes the ARC automatic alignment sequence throughout the laser chain from pulse initiation to target with an emphasis on the image processing algorithms that generate the crucial alignment positions for ARC. The image processing descriptions and flow diagrams detail the alignment control loops throughout the ARC laser chain beginning in the ARC high-contrast front end (HCAFE), on into the ARC main laser area, and ending in the ARC target area.

  18. Multi-energy spectral CT: adding value in emergency body imaging.

    Science.gov (United States)

    Punjabi, Gopal V

    2018-04-01

    Most vendors offer scanners capable of dual- or multi-energy computed tomography (CT) imaging. Advantages of multi-energy CT scanning include superior tissue characterization, detection of subtle iodine uptake differences, and opportunities to reduce contrast dose. However, utilization of this technology in the emergency department (ED) remains low. The purpose of this pictorial essay is to illustrate the value of multi-energy CT scanning in emergency body imaging.

  19. An Ultra-Low Power CMOS Image Sensor with On-Chip Energy Harvesting and Power Management Capability

    Directory of Open Access Journals (Sweden)

    Ismail Cevik

    2015-03-01

    Full Text Available An ultra-low power CMOS image sensor with on-chip energy harvesting and power management capability is introduced in this paper. The photodiode pixel array can not only capture images but also harvest solar energy. As such, the CMOS image sensor chip is able to switch between imaging and harvesting modes towards self-power operation. Moreover, an on-chip maximum power point tracking (MPPT-based power management system (PMS is designed for the dual-mode image sensor to further improve the energy efficiency. A new isolated P-well energy harvesting and imaging (EHI pixel with very high fill factor is introduced. Several ultra-low power design techniques such as reset and select boosting techniques have been utilized to maintain a wide pixel dynamic range. The chip was designed and fabricated in a 1.8 V, 1P6M 0.18 µm CMOS process. Total power consumption of the imager is 6.53 µW for a 96 × 96 pixel array with 1 V supply and 5 fps frame rate. Up to 30 μW of power could be generated by the new EHI pixels. The PMS is capable of providing 3× the power required during imaging mode with 50% efficiency allowing energy autonomous operation with a 72.5% duty cycle.

  20. SAFARI new and improved: extending the capabilities of SPICA's imaging spectrometer

    Science.gov (United States)

    Roelfsema, Peter; Giard, Martin; Najarro, Francisco; Wafelbakker, Kees; Jellema, Willem; Jackson, Brian; Sibthorpe, Bruce; Audard, Marc; Doi, Yasuo; di Giorgio, Anna; Griffin, Matthew; Helmich, Frank; Kamp, Inga; Kerschbaum, Franz; Meyer, Michael; Naylor, David; Onaka, Takashi; Poglitch, Albrecht; Spinoglio, Luigi; van der Tak, Floris; Vandenbussche, Bart

    2014-08-01

    The Japanese SPace Infrared telescope for Cosmology and Astrophysics, SPICA, aims to provide astronomers with a truly new window on the universe. With a large -3 meter class- cold -6K- telescope, the mission provides a unique low background environment optimally suited for highly sensitive instruments limited only by the cosmic background itself. SAFARI, the SpicA FAR infrared Instrument SAFARI, is a Fourier Transform imaging spectrometer designed to fully exploit this extremely low far infrared background environment. The SAFARI consortium, comprised of European and Canadian institutes, has established an instrument reference design based on a Mach-Zehnder interferometer stage with outputs directed to three extremely sensitive Transition Edge Sensor arrays covering the 35 to 210 μm domain. The baseline instrument provides R > 1000 spectroscopic imaging capabilities over a 2' by 2' field of view. A number of modifications to the instrument to extend its capabilities are under investigation. With the reference design SAFARI's sensitivity for many objects is limited not only by the detector NEP but also by the level of broad band background radiation - the zodiacal light for the shorter wavelengths and satellite baffle structures for the longer wavelengths. Options to reduce this background are dedicated masks or dispersive elements which can be inserted in the optics as required. The resulting increase in sensitivity can directly enhance the prime science goals of SAFARI; with the expected enhanced sensitivity astronomers would be in a better position to study thousands of galaxies out to redshift 3 and even many hundreds out to redshifts of 5 or 6. Possibilities to increase the wavelength resolution, at least for the shorter wavelength bands, are investigated as this would significantly enhance SAFARI's capabilities to study star and planet formation in our own galaxy.

  1. A study on the angle between the abdominal aorta and the superior mesenteric artery by 3D image reconstruction

    International Nuclear Information System (INIS)

    Kim, Young Keun; Choi, Sung Kwan

    2003-01-01

    SMAS (Superior Mesenteric Artery Syndrome) is a disease caused by a chronic obstruction of the duodenum (transverse portion ), which is hardly detectable. However, it is known that when the superior mesenteric artery and abdominal aorta form a narrow angle, that the transverse portion of the duodenum is pressed down between the superior mesenteric artery and the abdominal aorta, and that this can lead to obstruction of the duodenum. Measuring this angle is a complicated job using conventional angiography, and results often turns out to be inaccurate. In addition, no attempt has been made to determine the value of this angle in Koreans. In this study, we conducted abdominal CT angiography using MIP (maximum intensity projection) on patients with no clinical evidence of SMAS in order to determine the angle at which the superior mesenteric artery branches from the abdominal aorta by using PC based software (Rapidia ver. 1.2) for the image reconstruction. Accordingly, we found that the mean angle between the abdominal aorta and the superior mesenteric artery was 50.05 ± 15.87 .deg. on average, and that the angle in men (53.64 ± 16.57 .deg.) is higher than in women (46.46 ± 14.98 .deg. ). We hope that the angles determined by our study will serve as an important indicator for detecting SMAS

  2. Perturbation resilience and superiorization of iterative algorithms

    International Nuclear Information System (INIS)

    Censor, Y; Davidi, R; Herman, G T

    2010-01-01

    Iterative algorithms aimed at solving some problems are discussed. For certain problems, such as finding a common point in the intersection of a finite number of convex sets, there often exist iterative algorithms that impose very little demand on computer resources. For other problems, such as finding that point in the intersection at which the value of a given function is optimal, algorithms tend to need more computer memory and longer execution time. A methodology is presented whose aim is to produce automatically for an iterative algorithm of the first kind a 'superiorized version' of it that retains its computational efficiency but nevertheless goes a long way toward solving an optimization problem. This is possible to do if the original algorithm is 'perturbation resilient', which is shown to be the case for various projection algorithms for solving the consistent convex feasibility problem. The superiorized versions of such algorithms use perturbations that steer the process in the direction of a superior feasible point, which is not necessarily optimal, with respect to the given function. After presenting these intuitive ideas in a precise mathematical form, they are illustrated in image reconstruction from projections for two different projection algorithms superiorized for the function whose value is the total variation of the image

  3. Superior Canal Dehiscence Syndrome: Lessons from the First 20 Years

    Directory of Open Access Journals (Sweden)

    Bryan K. Ward

    2017-04-01

    Full Text Available Superior semicircular canal dehiscence syndrome was first reported by Lloyd Minor and colleagues in 1998. Patients with a dehiscence in the bone overlying the superior semicircular canal experience symptoms of pressure or sound-induced vertigo, bone conduction hyperacusis, and pulsatile tinnitus. The initial series of patients were diagnosed based on common symptoms, a physical examination finding of eye movements in the plane of the superior semicircular canal when ear canal pressure or loud tones were applied to the ear, and high-resolution computed tomography imaging demonstrating a dehiscence in the bone over the superior semicircular canal. Research productivity directed at understanding better methods for diagnosing and treating this condition has substantially increased over the last two decades. We now have a sound understanding of the pathophysiology of third mobile window syndromes, higher resolution imaging protocols, and several sensitive and specific diagnostic tests. Furthermore, we have a treatment (surgical occlusion of the superior semicircular canal that has demonstrated efficacy. This review will highlight some of the fundamental insights gained in SCDS, propose diagnostic criteria, and discuss future research directions.

  4. Security protection of DICOM medical images using dual-layer reversible watermarking with tamper detection capability.

    Science.gov (United States)

    Tan, Chun Kiat; Ng, Jason Changwei; Xu, Xiaotian; Poh, Chueh Loo; Guan, Yong Liang; Sheah, Kenneth

    2011-06-01

    Teleradiology applications and universal availability of patient records using web-based technology are rapidly gaining importance. Consequently, digital medical image security has become an important issue when images and their pertinent patient information are transmitted across public networks, such as the Internet. Health mandates such as the Health Insurance Portability and Accountability Act require healthcare providers to adhere to security measures in order to protect sensitive patient information. This paper presents a fully reversible, dual-layer watermarking scheme with tamper detection capability for medical images. The scheme utilizes concepts of public-key cryptography and reversible data-hiding technique. The scheme was tested using medical images in DICOM format. The results show that the scheme is able to ensure image authenticity and integrity, and to locate tampered regions in the images.

  5. An MRI Study of Superior Temporal Gyrus Volume in Women With Schizotypal Personality Disorder

    OpenAIRE

    Dickey, Chandlee C.; McCarley, Robert William; Voglmaier, Martina M.; Niznikiewicz, Margaret A.; Seidman, Larry Joel; Demeo, Susan; Frumin, Melissa; Shenton, Martha Elizabeth

    2003-01-01

    Objective: An abnormal superior temporal gyrus has figured prominently in schizophrenia research, and left superior temporal gyrus volume has been shown to be smaller in male subjects with schizotypal personality disorder. This is the first structural magnetic resonance imaging study to examine a group of female subjects with schizotypal personality disorder. Method: The superior temporal gyrus was drawn on coronal images acquired from female subjects recruited from the community (schizotypal...

  6. The superiority and benefits of whole body imaging after radioiodine -131 therapy over radioiodine 131 diagnostic imaging in management of thyroid carcinomas.

    Energy Technology Data Exchange (ETDEWEB)

    Aleid, M A [Al-Mostansyria university, college of medicine P.O.Box 14132, Baghdad, (Iraq)

    1995-10-01

    A comparison between diagnostic and post therapeutic radioiodine imaging methods utilized in detection of thyroid metastases in 34 patients with well differentiated thyroid cancer was performed. The study revealed that the differences in detection on neck activity only between the two methods for papillary and follicular thyroid cancer were 35% and 27% respectively. While the overall detection percentages in both papillary and follicular thyroid cancers cases were 23% in diagnostic and 76% in post therapy scintigrams and the detection difference between the methods was 53% when all lesions throughout the body were seen on scintigram for only follicular thyroid cancer cases were counted, the detection percentage was increased up to 109%. It is clear that post therapeutic scans visualize an additional site activity not shown in diagnostic scans. There fore, post therapeutic imaging method is far superior to diagnostic imaging method and highly sensitive in visualization of thyroid metastases. On the other hand, this research also achieves many scientific and financial benefits. Therefore. This method should be adopted in management and follow up of well differentiated malignancies. 2 figs., 2 tabs.

  7. The superiority and benefits of whole body imaging after radioiodine -131 therapy over radioiodine 131 diagnostic imaging in management of thyroid carcinomas

    International Nuclear Information System (INIS)

    Aleid, M.A.

    1995-01-01

    A comparison between diagnostic and post therapeutic radioiodine imaging methods utilized in detection of thyroid metastases in 34 patients with well differentiated thyroid cancer was performed. The study revealed that the differences in detection on neck activity only between the two methods for papillary and follicular thyroid cancer were 35% and 27% respectively. While the overall detection percentages in both papillary and follicular thyroid cancers cases were 23% in diagnostic and 76% in post therapy scintigrams and the detection difference between the methods was 53% when all lesions throughout the body were seen on scintigram for only follicular thyroid cancer cases were counted, the detection percentage was increased up to 109%. It is clear that post therapeutic scans visualize an additional site activity not shown in diagnostic scans. There fore, post therapeutic imaging method is far superior to diagnostic imaging method and highly sensitive in visualization of thyroid metastases. On the other hand, this research also achieves many scientific and financial benefits. Therefore. This method should be adopted in management and follow up of well differentiated malignancies. 2 figs., 2 tabs

  8. Evolution of the Imaging Tests in Hemophilia with Emphasis on Radiography and Magnetic Resonance Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kilcoyne, R.F. [Univ. of Colorado Health Sciences Center, Denver, CO (United States). Dept. of Radiology; Lundin, B.; Pettersson, H. [Univ. Hospital of Lund (Sweden). Dept. of Radiology

    2006-04-15

    Even before the discovery of X-rays in 1895 attempts were being made to classify the joint destruction that occurs in hemophilic arthropathy. The advent of radiography added impetus to the search for the optimum classification system. Subsequent attempts have included advanced imaging methods, especially magnetic resonance imaging (MRI). Because of its high spatial resolution and ability to visualize soft tissue abnormalities, MRI is ideally suited as the best way to classify arthropathy. A literature search was carried out to document and list all the imaging methods for hemophilic arthropathy that have been published up to the present. All published classification systems are discussed and listed in tables. MRI has superior imaging capability and will probably become the most important modality for radiological classification of hemophilic arthropathy in the future.

  9. Evolution of the Imaging Tests in Hemophilia with Emphasis on Radiography and Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Kilcoyne, R.F.; Lundin, B.; Pettersson, H.

    2006-01-01

    Even before the discovery of X-rays in 1895 attempts were being made to classify the joint destruction that occurs in hemophilic arthropathy. The advent of radiography added impetus to the search for the optimum classification system. Subsequent attempts have included advanced imaging methods, especially magnetic resonance imaging (MRI). Because of its high spatial resolution and ability to visualize soft tissue abnormalities, MRI is ideally suited as the best way to classify arthropathy. A literature search was carried out to document and list all the imaging methods for hemophilic arthropathy that have been published up to the present. All published classification systems are discussed and listed in tables. MRI has superior imaging capability and will probably become the most important modality for radiological classification of hemophilic arthropathy in the future

  10. Dual-band infrared capabilities for imaging buried object sites

    Energy Technology Data Exchange (ETDEWEB)

    Del Grande, N.K.; Durbin, P.F.; Gorvad, M.R.; Perkins, D.E.; Clark, G.A.; Hernandez, J.E.; Sherwood, R.J.

    1993-04-02

    We discuss dual-band infrared (DBIR) capabilities for imaging buried object sizes. We identify physical features affecting thermal contrast needed to distinguish buried object sites from undisturbed sites or surface clutter. Apart from atmospheric transmission and system performance, these features include: object size, shape, and burial depth; ambient soil, disturbed soil and object site thermal diffusivity differences; surface temperature, emissivity, plant-cover, slope, albedo and roughness variations; weather conditions and measurement times. We use good instrumentation to measure the time-varying temperature differences between buried object sites and undisturbed soil sites. We compare near surface soil temperature differences with radiometric infrared (IR) surface temperature differences recorded at 4.7 {plus_minus} 0.4 {mu}m and at 10.6 {plus_minus} 1.0 {mu}m. By producing selective DBIR image ratio maps, we distinguish temperature-difference patterns from surface emissivity effects. We discuss temperature differences between buried object sites, filled hole site (without buried objects), cleared (undisturbed) soil sites, and grass-covered sites (with and without different types of surface clutter). We compare temperature, emissivity-ratio, visible and near-IR reflectance signatures of surface objects, leafy plants and sod. We discuss the physical aspects of environmental, surface and buried target features affecting interpretation of buried targets, surface objects and natural backgrounds.

  11. High-resolution, time-resolved MRA provides superior definition of lower-extremity arterial segments compared to 2D time-of-flight imaging.

    Science.gov (United States)

    Thornton, F J; Du, J; Suleiman, S A; Dieter, R; Tefera, G; Pillai, K R; Korosec, F R; Mistretta, C A; Grist, T M

    2006-08-01

    To evaluate a novel time-resolved contrast-enhanced (CE) projection reconstruction (PR) magnetic resonance angiography (MRA) method for identifying potential bypass graft target vessels in patients with Class II-IV peripheral vascular disease. Twenty patients (M:F = 15:5, mean age = 58 years, range = 48-83 years), were recruited from routine MRA referrals. All imaging was performed on a 1.5 T MRI system with fast gradients (Signa LX; GE Healthcare, Waukesha, WI). Images were acquired with a novel technique that combined undersampled PR with a time-resolved acquisition to yield an MRA method with high temporal and spatial resolution. The method is called PR hyper time-resolved imaging of contrast kinetics (PR-hyperTRICKS). Quantitative and qualitative analyses were used to compare two-dimensional (2D) time-of-flight (TOF) and PR-hyperTRICKS in 13 arterial segments per lower extremity. Statistical analysis was performed with the Wilcoxon signed-rank test. Fifteen percent (77/517) of the vessels were scored as missing or nondiagnostic with 2D TOF, but were scored as diagnostic with PR-hyperTRICKS. Image quality was superior with PR-hyperTRICKS vs. 2D TOF (on a four-point scale, mean rank = 3.3 +/- 1.2 vs. 2.9 +/- 1.2, P < 0.0001). PR-hyperTRICKS produced images with high contrast-to-noise ratios (CNR) and high spatial and temporal resolution. 2D TOF images were of inferior quality due to moderate spatial resolution, inferior CNR, greater flow-related artifacts, and absence of temporal resolution. PR-hyperTRICKS provides superior preoperative assessment of lower limb ischemia compared to 2D TOF.

  12. Gadolinium-Enhanced Three-Dimensional Magnetization - Prepared Rapid Gradient-Echo (3D MP-RAGE) Imaging is Superior to Spin-Echo Imaging in Delineating Brain Metastases

    International Nuclear Information System (INIS)

    Takeda, T.; Takeda, A.; Nagaoka, T.; Kunieda, E.; Takemasa, K.; Watanabe, M.; Hatou, T.; Oguro, S.; Katayama, M.

    2008-01-01

    Background: Precisely defining the number and location of brain metastases is very important for establishing a treatment strategy for malignancies. Although magnetic resonance imaging (MRI) is now considered the best modality, various improvements in sequences are still being made. Purpose: To prospectively compare the diagnostic ability of three-dimensional, magnetization-prepared rapid gradient-echo (3D MP-RAGE) imaging in detecting metastatic brain tumors, with that of two-dimensional spin-echo (2D SE) T1-weighted imaging. Material and Methods: A total of 123 examinations were included in this study, and 119 examinations from 88 patients with known malignancies were analyzed. All patients underwent T1- and T2-weighted 2D SE transverse imaging, followed by gadolinium-enhanced T1-weighted transverse and coronal 2D SE imaging and 3D MP-RAGE transverse imaging. Four radiologists interpreted the images to compare the accuracy and the time required for interpretation for each imaging. Results: 3D MP-RAGE imaging was significantly better than 2D SE imaging for detecting metastatic brain lesions, regardless of the readers' experience. The sensitivities of the 3D MP-RAGE and 2D SE imaging for all observers were 0.81 vs. 0.80 (P>0.05), specificities were 0.93 vs. 0.87 (P 0.05), and accuracies were 0.84 vs. 0.78 (P<0.05), respectively. There was no significant difference in the time required for image interpretation between the two modalities (15.6±4.0 vs. 15.4±4.1 min). Conclusion: 3D MP-RAGE imaging proved superior to 2D SE imaging in the detection of brain metastases

  13. AXIS: An instrument for imaging Compton radiographs using the Advanced Radiography Capability on the NIF

    Energy Technology Data Exchange (ETDEWEB)

    Hall, G. N., E-mail: hall98@llnl.gov; Izumi, N.; Tommasini, R.; Carpenter, A. C.; Palmer, N. E.; Zacharias, R.; Felker, B.; Holder, J. P.; Allen, F. V.; Bell, P. M.; Bradley, D.; Montesanti, R.; Landen, O. L. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550 (United States)

    2014-11-15

    Compton radiography is an important diagnostic for Inertial Confinement Fusion (ICF), as it provides a means to measure the density and asymmetries of the DT fuel in an ICF capsule near the time of peak compression. The AXIS instrument (ARC (Advanced Radiography Capability) X-ray Imaging System) is a gated detector in development for the National Ignition Facility (NIF), and will initially be capable of recording two Compton radiographs during a single NIF shot. The principal reason for the development of AXIS is the requirement for significantly improved detection quantum efficiency (DQE) at high x-ray energies. AXIS will be the detector for Compton radiography driven by the ARC laser, which will be used to produce Bremsstrahlung X-ray backlighter sources over the range of 50 keV–200 keV for this purpose. It is expected that AXIS will be capable of recording these high-energy x-rays with a DQE several times greater than other X-ray cameras at NIF, as well as providing a much larger field of view of the imploded capsule. AXIS will therefore provide an image with larger signal-to-noise that will allow the density and distribution of the compressed DT fuel to be measured with significantly greater accuracy as ICF experiments are tuned for ignition.

  14. AXIS: an instrument for imaging Compton radiographs using the Advanced Radiography Capability on the NIF.

    Science.gov (United States)

    Hall, G N; Izumi, N; Tommasini, R; Carpenter, A C; Palmer, N E; Zacharias, R; Felker, B; Holder, J P; Allen, F V; Bell, P M; Bradley, D; Montesanti, R; Landen, O L

    2014-11-01

    Compton radiography is an important diagnostic for Inertial Confinement Fusion (ICF), as it provides a means to measure the density and asymmetries of the DT fuel in an ICF capsule near the time of peak compression. The AXIS instrument (ARC (Advanced Radiography Capability) X-ray Imaging System) is a gated detector in development for the National Ignition Facility (NIF), and will initially be capable of recording two Compton radiographs during a single NIF shot. The principal reason for the development of AXIS is the requirement for significantly improved detection quantum efficiency (DQE) at high x-ray energies. AXIS will be the detector for Compton radiography driven by the ARC laser, which will be used to produce Bremsstrahlung X-ray backlighter sources over the range of 50 keV-200 keV for this purpose. It is expected that AXIS will be capable of recording these high-energy x-rays with a DQE several times greater than other X-ray cameras at NIF, as well as providing a much larger field of view of the imploded capsule. AXIS will therefore provide an image with larger signal-to-noise that will allow the density and distribution of the compressed DT fuel to be measured with significantly greater accuracy as ICF experiments are tuned for ignition.

  15. Revising Amartya Sen's Capability Approach to Education for Ethical Development

    Science.gov (United States)

    Mok, Kwangsu; Jeong, Wongyu

    2016-01-01

    The purpose of this paper is to examine whether Amartya Sen's capability approach can suggest an appropriate theory of education for ethical development. Many advocates of Sen's capability approach insist that his approach is superior to rival theories of education, including the human capital theory. This is because Sen emphasizes the purpose and…

  16. Experimental test of the background rejection, through imaging capability, of a highly segmented AGATA germanium detector

    International Nuclear Information System (INIS)

    Doncel, M.; Recchia, F.; Quintana, B.; Gadea, A.; Farnea, E.

    2010-01-01

    The development of highly segmented germanium detectors as well as the algorithms to identify the position of the interaction within the crystal opens the possibility to locate the γ-ray source using Compton imaging algorithms. While the Compton-suppression shield, coupled to the germanium detector in conventional arrays, works also as an active filter against the γ rays originated outside the target, the new generation of position sensitive γ-ray detector arrays has to fully rely on tracking capabilities for this purpose. In specific experimental conditions, as the ones foreseen at radioactive beam facilities, the ability to discriminate background radiation improves the sensitivity of the gamma spectrometer. In this work we present the results of a measurement performed at the Laboratori Nazionali di Legnaro (LNL) aiming the evaluation of the AGATA detector capabilities to discriminate the origin of the γ rays on an event-by-event basis. It will be shown that, exploiting the Compton scattering formula, it is possible to track back γ rays coming from different positions, assigning them to specific emitting locations. These imaging capabilities are quantified for a single crystal AGATA detector.

  17. Capabilities and prospects of the East Asia Very Long Baseline Interferometry Network

    Science.gov (United States)

    An, T.; Sohn, B. W.; Imai, H.

    2018-02-01

    The very long baseline interferometry (VLBI) technique offers angular resolutions superior to any other instruments at other wavelengths, enabling unique science applications of high-resolution imaging of radio sources and high-precision astrometry. The East Asia VLBI Network (EAVN) is a collaborative effort in the East Asian region. The EAVN currently consists of 21 telescopes with diverse equipment configurations and frequency setups, allowing flexible subarrays for specific science projects. The EAVN provides the highest resolution of 0.5 mas at 22 GHz, allowing the fine imaging of jets in active galactic nuclei, high-accuracy astrometry of masers and pulsars, and precise spacecraft positioning. The soon-to-be-operational Five-hundred-meter Aperture Spherical radio Telescope (FAST) will open a new era for the EAVN. This state-of-the-art VLBI array also provides easy access to and crucial training for the burgeoning Asian astronomical community. This Perspective summarizes the status, capabilities and prospects of the EAVN.

  18. A small-animal imaging system capable of multipinhole circular/helical SPECT and parallel-hole SPECT

    International Nuclear Information System (INIS)

    Qian Jianguo; Bradley, Eric L.; Majewski, Stan; Popov, Vladimir; Saha, Margaret S.; Smith, Mark F.; Weisenberger, Andrew G.; Welsh, Robert E.

    2008-01-01

    We have designed and built a small-animal single-photon emission computed tomography (SPECT) imaging system equipped with parallel-hole and multipinhole collimators and capable of circular or helical SPECT. Copper-beryllium parallel-hole collimators suitable for imaging the ∼35 keV photons from the decay of 125 I have been built and installed to achieve useful spatial resolution over a range of object-detector distances and to reduce imaging time on our dual-detector array. To address the resolution limitations in the parallel-hole SPECT and the sensitivity and limited field of view of single-pinhole SPECT, we have incorporated multipinhole circular and helical SPECT in addition to expanding the parallel-hole SPECT capabilities. The pinhole SPECT system is based on a 110 mm diameter circular detector equipped with a pixellated NaI(Tl) scintillator array (1x1x5 mm 3 /pixel). The helical trajectory is accomplished by two stepping motors controlling the rotation of the detector-support gantry and displacement of the animal bed along the axis of rotation of the gantry. Results obtained in SPECT studies of various phantoms show an enlarged field of view, very good resolution and improved sensitivity using multipinhole circular or helical SPECT. Collimators with one, three and five, 1-mm-diameter pinholes have been implemented and compared in these tests. Our objective is to develop a system on which one may readily select a suitable mode of either parallel-hole SPECT or pinhole circular or helical SPECT for a variety of small animal imaging applications

  19. MR imaging of the spine: trauma and degenerative disease

    International Nuclear Information System (INIS)

    Wilmink, J.T.

    1999-01-01

    The purpose of this paper is to discuss the capabilities and drawbacks of MR imaging in patients with trauma to the spine and degenerative spinal conditions. In spinal trauma MR imaging is secondary to plain X-ray films and CT because of the greater availability and ease of performance of these techniques and their superior capability for detecting vertebral fractures. Magnetic resonance imaging is useful for detecting ligamentous ruptures and intraspinal mass lesions such as hematoma, and for assessing the state of the spinal cord and prognosis of a cord injury. In degenerative spinal disease the necessity is emphasized of critically evaluating the clinical relevance of any abnormal feature detected, as findings of degenerative pathology are common in individuals without symptoms. Magnetic resonance myelography permits rapid and accurate assessment of the state of the lumbar nerve roots (compressed or not). In the cervical region the quality of the myelographic picture is often degraded in patients with a narrow spinal canal. (orig.)

  20. MR imaging of the spine: trauma and degenerative disease

    Energy Technology Data Exchange (ETDEWEB)

    Wilmink, J.T. [Department of Radiology, University Hospital Maastricht (Netherlands)

    1999-09-01

    The purpose of this paper is to discuss the capabilities and drawbacks of MR imaging in patients with trauma to the spine and degenerative spinal conditions. In spinal trauma MR imaging is secondary to plain X-ray films and CT because of the greater availability and ease of performance of these techniques and their superior capability for detecting vertebral fractures. Magnetic resonance imaging is useful for detecting ligamentous ruptures and intraspinal mass lesions such as hematoma, and for assessing the state of the spinal cord and prognosis of a cord injury. In degenerative spinal disease the necessity is emphasized of critically evaluating the clinical relevance of any abnormal feature detected, as findings of degenerative pathology are common in individuals without symptoms. Magnetic resonance myelography permits rapid and accurate assessment of the state of the lumbar nerve roots (compressed or not). In the cervical region the quality of the myelographic picture is often degraded in patients with a narrow spinal canal. (orig.) With 10 figs., 14 refs.

  1. Service-Oriented Architecture Afloat: A Capabilities-Based Prioritization Scheme

    Science.gov (United States)

    2013-04-01

    to “information superiority,” ultimately enhancing warfighting capability. Introduction The Program Executive Office for Command, Control...gateway architecture for IP satellite networks with dynamic resource mangement and DiffServ QoS provision. International Journal of Satellite

  2. MR imaging of the lumber spine; Visualization capability of the nerve root

    Energy Technology Data Exchange (ETDEWEB)

    Ishibashi, Kazumasa; Hieda, Hiroshi; Goto, Takeshi; Goto, Hiroshi; Koga, Hiromichi; Hiraoka, Kouji (Moji Rousai Hospital, Fukuoka (Japan))

    1991-01-01

    We studied visualization capability of the nerve root in mainly coronary section pattern using magnetic resonance imaging (MRI). MRI was carried out in 91 patients with lumbago and sciatica. Coronary section was additionally photographed in 58 cases of these patients (32 with intervertebral hernia, 20 with spinal canal stenosis, 2 with spondylolytic spondylolisthesis, 2 with compression fracture and the other 2 patients). The visualization capability of the nerve root was studied with photographing 2 pulse systems of the coronary section by using spin echo and field echo methods. The high signal area of the cerebrospinal fluid and nerve root in the normal lumbar vertebra was noted by field echo method, and pattern that is visualized by myelogram was obtained. The coincidence of the main foci (disturbed lesions of the nerve root) in the intervertebral hernia and coronary section pattern was noted in 21 of 32 cases (64.5%) with considerably high ratio. The condition of the nerve root in the blocked lesion was visualized in the spinal canal stenosis. (author).

  3. Ruptured superior gluteal artery pseudoaneurysm with hemorrhagic shock: Case report

    Directory of Open Access Journals (Sweden)

    Kerem Seref Corbacioglu

    2016-03-01

    Full Text Available Pseudoaneurysm of the superior gluteal artery (SGA is very rare and the most common causes are blunt or penetrating pelvic traumas. Although pseudoaneurysm can be asymptomatic at the time of initial trauma, it can be symptomatic weeks, months, even years after initial trauma. We present a case of a ruptured superior gluteal artery pseudoaneurysm with hemorrhagic shock twenty days after a bomb injury in the Syria civil war. In addition, we review the anatomy of the SGA, clinical presentation and pitfalls of pseudoaneurysm, and imaging and treatment options. Keywords: Pseudoaneurysm, Superior gluteal artery, Pitfall, Angiography

  4. The aperture synthesis imaging capability of the EISCAT_3D radars

    Science.gov (United States)

    La Hoz, Cesar; Belyey, Vasyl

    2010-05-01

    The built-in Aperture Synthesis Imaging Radar (ASIR) capabilities of the EISCAT_3D system, complemented with multiple beams and rapid beam scanning, is what will make the new radar truly three dimensional and justify its name. With the EISCAT_3D radars it will be possible to make investigations in 3-dimensions of several important phenomena such as Natural Enhanced Ion Acoustic Lines (NEIALs), Polar Mesospheric Summer and Winter Echoes (PMSE and PMWE), meteors, space debris, atmospheric waves and turbulence in the mesosphere, upper troposphere and possibly the lower stratosphere. Of particular interest and novelty is the measurement of the structure in electron density created by aurora that produce incoherent scatter. With scale sizes of the order of tens of meters, the imaging of these structures will be conditioned only by the signal to noise ratio which is expected to be high during some of these events, since the electron density can be significantly enhanced. The electron density inhomogeneities and plasma structures excited by artificial ionospheric heating could conceivable be resolved by the radars provided that their variation during the integration time is not great.

  5. Image enhancement using thermal-visible fusion for human detection

    Science.gov (United States)

    Zaihidee, Ezrinda Mohd; Hawari Ghazali, Kamarul; Zuki Saleh, Mohd

    2017-09-01

    An increased interest in detecting human beings in video surveillance system has emerged in recent years. Multisensory image fusion deserves more research attention due to the capability to improve the visual interpretability of an image. This study proposed fusion techniques for human detection based on multiscale transform using grayscale visual light and infrared images. The samples for this study were taken from online dataset. Both images captured by the two sensors were decomposed into high and low frequency coefficients using Stationary Wavelet Transform (SWT). Hence, the appropriate fusion rule was used to merge the coefficients and finally, the final fused image was obtained by using inverse SWT. From the qualitative and quantitative results, the proposed method is more superior than the two other methods in terms of enhancement of the target region and preservation of details information of the image.

  6. Magnetic resonance imaging of the abdomen

    International Nuclear Information System (INIS)

    Kulkarni, M.V.

    1986-01-01

    MRI of the abdomen currently competes with CT and ultrasonography as an imaging technique for abdominal pathology. Although ultrasonography has certain advantages, such as real-time scanning, the major comparison is to be made between MR and CT. CT has slightly superior spatial resolution and minimal motion artifacts, and enables the use of contrast agents in bowel. MR, on the other hand, has improved capabilities in contrasting soft tissues and providing multiplanar imaging. The greatest advantage of CT is the experience that the medical community has gained with it over the last decade. Further development in technology and improvement in the clinical experience with MR will be important in determining its future role in abdominal imaging. Large series of clinical trials are required for further experience. Chemical spectroscopy with proton and possibly other nuclei may improve diagnostic specificity. Paramagnetic contrast agents for bowel specification would certainly improve imaging quality. Thus, MR will play a significant role in abdominal imaging in the future

  7. A method for digital image registration using a mathematical programming technique

    Science.gov (United States)

    Yao, S. S.

    1973-01-01

    A new algorithm based on a nonlinear programming technique to correct the geometrical distortions of one digital image with respect to another is discussed. This algorithm promises to be superior to existing ones in that it is capable of treating localized differential scaling, translational and rotational errors over the whole image plane. A series of piece-wise 'rubber-sheet' approximations are used, constrained in such a manner that a smooth approximation over the entire image can be obtained. The theoretical derivation is included. The result of using the algorithm to register four channel S065 Apollo IX digitized photography over Imperial Valley, California, is discussed in detail.

  8. Dual-energy CT and ceramic or titanium prostheses material reduce CT artifacts and provide superior image quality of total knee arthroplasty.

    Science.gov (United States)

    Kasparek, Maximilian F; Töpker, Michael; Lazar, Mathias; Weber, Michael; Kasparek, Michael; Mang, Thomas; Apfaltrer, Paul; Kubista, Bernd; Windhager, Reinhard; Ringl, Helmut

    2018-06-07

    To evaluate the influence of different scan parameters for single-energy CT and dual-energy CT, as well as the impact of different material used in a TKA prosthesis on image quality and the extent of metal artifacts. Eight pairs of TKA prostheses from different vendors were examined in a phantom set-up. Each pair consisted of a conventional CoCr prosthesis and the corresponding anti-allergic prosthesis (full titanium, ceramic, or ceramic-coated) from the same vendor. Nine different (seven dual-energy CT and two single-energy CT) scan protocols with different characteristics were used to determine the most suitable CT protocol for TKA imaging. Quantitative image analysis included assessment of blooming artifacts (metal implants appear thicker on CT than they are, given as virtual growth in mm in this paper) and streak artifacts (thick dark lines around metal). Qualitative image analysis was used to investigate the bone-prosthesis interface. The full titanium prosthesis and full ceramic knee showed significantly fewer blooming artifacts compared to the standard CoCr prosthesis (mean virtual growth 0.6-2.2 mm compared to 2.9-4.6 mm, p energy CT protocols showed less blooming (range 3.3-3.8 mm) compared to single-energy protocols (4.6-5.5 mm). The full titanium and full ceramic prostheses showed significantly fewer streak artifacts (mean standard deviation 77-86 Hounsfield unit (HU)) compared to the standard CoCr prosthesis (277-334 HU, p energy CT protocols had fewer metal streak artifacts (215-296 HU compared to single-energy CT protocols (392-497 HU)). Full titanium and ceramic prostheses were ranked superior with regard to the image quality at the bone/prosthesis interface compared to a standard CoCr prosthesis, and all dual-energy CT protocols were ranked better than single-energy protocols. Dual-energy CT and ceramic or titanium prostheses reduce CT artifacts and provide superior image quality of total knee arthroplasty at the bone/prosthesis interface

  9. Learning Joint-Sparse Codes for Calibration-Free Parallel MR Imaging.

    Science.gov (United States)

    Wang, Shanshan; Tan, Sha; Gao, Yuan; Liu, Qiegen; Ying, Leslie; Xiao, Taohui; Liu, Yuanyuan; Liu, Xin; Zheng, Hairong; Liang, Dong

    2018-01-01

    The integration of compressed sensing and parallel imaging (CS-PI) has shown an increased popularity in recent years to accelerate magnetic resonance (MR) imaging. Among them, calibration-free techniques have presented encouraging performances due to its capability in robustly handling the sensitivity information. Unfortunately, existing calibration-free methods have only explored joint-sparsity with direct analysis transform projections. To further exploit joint-sparsity and improve reconstruction accuracy, this paper proposes to Learn joINt-sparse coDes for caliBration-free parallEl mR imaGing (LINDBERG) by modeling the parallel MR imaging problem as an - - minimization objective with an norm constraining data fidelity, Frobenius norm enforcing sparse representation error and the mixed norm triggering joint sparsity across multichannels. A corresponding algorithm has been developed to alternatively update the sparse representation, sensitivity encoded images and K-space data. Then, the final image is produced as the square root of sum of squares of all channel images. Experimental results on both physical phantom and in vivo data sets show that the proposed method is comparable and even superior to state-of-the-art CS-PI reconstruction approaches. Specifically, LINDBERG has presented strong capability in suppressing noise and artifacts while reconstructing MR images from highly undersampled multichannel measurements.

  10. Subliminal food images compromise superior working memory performance in women with restricting anorexia nervosa.

    Science.gov (United States)

    Brooks, Samantha J; O'Daly, Owen G; Uher, Rudolf; Schiöth, Helgi B; Treasure, Janet; Campbell, Iain C

    2012-06-01

    Prefrontal cortex (PFC) is dysregulated in women with restricting anorexia nervosa (RAN). It is not known whether appetitive non-conscious stimuli bias cognitive responses in those with RAN. Thirteen women with RAN and 20 healthy controls (HC) completed a dorsolateral PFC (DLPFC) working memory task and an anterior cingulate cortex (ACC) conflict task, while masked subliminal food, aversive and neutral images were presented. During the DLPFC task, accuracy was higher in the RAN compared to the HC group, but superior performance was compromised when subliminal food stimuli were presented: errors positively correlated with self-reported trait anxiety in the RAN group. These effects were not observed in the ACC task. Appetitive activation is intact and anxiogenic in women with RAN, and non-consciously interacts with working memory processes associated with the DLPFC. This interaction mechanism may underlie cognitive inhibition of appetitive processes that are anxiety inducing, in people with AN. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. T2-weighted fast spin-echo MR imaging of the pelvis

    International Nuclear Information System (INIS)

    Francis, I.R.; Steiner, R.M.; Herfkens, R.J.; Jain, K.; Glover, G.H.

    1991-01-01

    A fast Se (FSE) sequence capable of acquiring SE images with a wide range of TRs and TEs in short imaging times has been recently introduced. I this paper, the authors evaluated the value of this technique compared with standard T2-weighted SE imaging. Twenty-five patients were evaluated with T2-weighted SE and FSE images on a 1.5-T GE Signa imager. Imaging times ranged from 3 to 5 minutes for the FSE acquisition and from 12 to 15 minutes for the SE images. Three observers performed a comparison by using a 10-point scale for organ definition and lesion conspicuity, with differences settled by consensus reading. Pelvic organ definition was superior and pelvic tumors and free fluid were also more conspicuous on FSE images. In 2/25 patients ringing artifacts were present

  12. Diagnostic imaging of injuries and overuse in soccer players

    International Nuclear Information System (INIS)

    Jonge, M.C. de; Maas, M.; Kuijk, C. van

    2002-01-01

    Soccer is one of the most popular sports worldwide. There is a high incidence of injuries in soccer in which several intrinsic and extrinsic factors play a part. Most injuries are minor, self-limiting and do not need extensive medical treatment or imaging. Imaging can be required for several reasons e.g. when the clinical findings are doubtful, to replace arthroscopy (i. e. of the knee) or for prognostic reasons. All imaging modalities available to the radiologist can be used but MRI is the most valuable imaging modality with its superior contrast resolution and multiplanar capabilities. Basically, injuries in the soccer player can occur anywhere in the body like in every sport. The lower extremities, more specific the knee and ankle, are however the most injured parts. (orig.) [de

  13. Agenesia de cava superior associada a bloqueio atrioventricular de 3º grau Agenesis of the right superior vena cava associated with total heart block

    Directory of Open Access Journals (Sweden)

    Gustavo J. Ventura Couto

    2008-03-01

    Full Text Available A persistência de veia cava superior esquerda com ausência da veia cava superior é uma anomalia rara, principalmente quando associada a bloqueio atrioventricular de 3º grau. Relatamos o caso de uma paciente, na qual durante implante de marca-passo definitivo, para a correção de bloqueio atrioventricular total, foi detectada presença de veia cava superior esquerda com suspeição de ausência de veia cava superior, o que levou ao emprego de técnica diferenciada para fixação do eletrodo ventricular. Para confirmação da provável agenesia, foram realizados diversos exames complementares de imagem, demonstrando-se a dificuldade no diagnóstico da síndrome aqui descrita.The superior left vena cava with the absent superior vena cava is a rare abnormality, especially when associated with total heart block. We report a case of a patient in which the presence of superior left vena cava and the absence of the superior vena cava was detected during the implantation of a pacemaker for the correction of a total heart block, which led us to use a different technique for the fixation of the ventricular electrode. To confirm the supposed absence, several image exams were made showing the difficulty on the diagnosis of the described syndrome.

  14. Double elevator weakening for unilateral congenital superior oblique palsy with ipsilateral superior rectus contracture and lax superior oblique tendon.

    Science.gov (United States)

    Khan, Arif O

    2012-06-01

    In unilateral congenital superior oblique palsy, a large hypertropia is sometimes associated with ipsilateral contracture of the superior rectus muscle and apparent overaction of the contralateral superior oblique. Ipsilateral double elevator weakening is one surgical approach; however, this procedure could compromise supraduction. We report a series of three consecutive patients who underwent ipsilateral superior rectus and inferior oblique recessions for unilateral superior oblique palsy. Intraoperatively, all three patients were found to have a lax ipsilateral superior oblique tendon. Postoperatively, all three patients had satisfactory correction of the hypertropia and abnormal head position with minimal supraduction defect. This procedure seems to be an acceptable initial surgical option for treating congenital superior oblique muscle palsy with ipsilateral contracture of the superior rectus muscle, even when the ipsilateral superior oblique tendon is lax. Copyright © 2012 American Association for Pediatric Ophthalmology and Strabismus. Published by Mosby, Inc. All rights reserved.

  15. Diagnostic radiology of apoplexy - imaging of cerebral ischemia

    International Nuclear Information System (INIS)

    Rieber, A.; Tomczak, R.; Brambs, H.J.

    1998-01-01

    The recent enhancements achieved in CT and MR imaging techniques have launched a debate about the techniques preferrably to be applied for diagnostic evaluation of acute cerebral stroke. At present, CT still is the modality of choice for primary evaluation of cerebral ischemia, due to relative cost-effectiveness, high availability, and the capability to reliably differentiate ischemia from hemorrhage. MRI on the other hand is superior to CT in detecting and imaging the infarction area within the first few hours, especially if the technique of diffusion-weighted sequencing is applied. Current research focuses on determining whether MRI with perfusion and diffusion-weighted sequencing will yield images distinctly showing the penumbra on the one hand, and the damaged brain tissue on the other. It remains to be seen whether improved tomographic imaging will lead to novel approaches for therapy. (orig./CB) [de

  16. Accommodation and convergence palsy caused by lesions in the bilateral rostral superior colliculus.

    Science.gov (United States)

    Ohtsuka, Kenji; Maeda, Sachie; Oguri, Naomi

    2002-03-01

    To report a patient who developed accommodation and convergence palsy caused by lesions in the bilateral rostral superior colliculus. Observational case report. A 30-year-old right-handed man experienced sudden onset of diplopia and blurred vision at near vision. The patient showed accommodation and convergence palsy. Magnetic resonance imaging revealed lesions located in the bilateral rostral superior colliculus. These findings suggest that the rostral superior colliculus is involved in the control of accommodation and vergence eye movements.

  17. Magnetic resonance imaging in hypertrophic cardiomyopathy

    International Nuclear Information System (INIS)

    Ichida, Fukiko; Hamamichi, Yuuji; Hashimoto, Ikuo; Tsubata, Shinichi; Miyazaki, Ayumi; Okada, Toshio; Futatsuya, Ryuusuke; Okada, Eikichi

    1994-01-01

    To evaluate the capability of magnetic resonance imaging (MRI) in the anatomical diagnosis and tissue characterization, 8 children with hypertrophic cardiomyopathy were studied comparing with echocardiography and 201 Tl myocardial imaging. The severity and distribution of hypertrophy were comparable on echocardiography and MRI. MRI was superior to echocardiography to demonstrate the apical hypertrophy. In 4 patients with severe hypertrophy, heterogenous high signal intensity was demonstrated in the site of hypertrophy, which was enhanced by T 2 weighted imaging. In the patient with decreased cardiac performance and progressed cardiac failure, the heterogeneity and high signal intensity progressed in one year interval. Simultaneously performed 201 Tl myocardial imaging showed patchy perfusion defect. Histological findings of the left ventricle demonstrated hypertrophy, degeneration and marked dysarray of the myocytes and fibrosis. MRI has the potential ability for the evaluation and sequential monitoring of myocardial tissue characterization as well as cardiac anatomy in childhood hypertrophic cardiomyopathy. (author)

  18. Magnetic resonance imaging in hypertrophic cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Ichida, Fukiko; Hamamichi, Yuuji; Hashimoto, Ikuo; Tsubata, Shinichi; Miyazaki, Ayumi; Okada, Toshio; Futatsuya, Ryuusuke; Okada, Eikichi [Toyama Medical and Pharmaceutical Univ. (Japan)

    1994-02-01

    To evaluate the capability of magnetic resonance imaging (MRI) in the anatomical diagnosis and tissue characterization, 8 children with hypertrophic cardiomyopathy were studied comparing with echocardiography and [sup 201]Tl myocardial imaging. The severity and distribution of hypertrophy were comparable on echocardiography and MRI. MRI was superior to echocardiography to demonstrate the apical hypertrophy. In 4 patients with severe hypertrophy, heterogenous high signal intensity was demonstrated in the site of hypertrophy, which was enhanced by T[sub 2] weighted imaging. In the patient with decreased cardiac performance and progressed cardiac failure, the heterogeneity and high signal intensity progressed in one year interval. Simultaneously performed [sup 201]Tl myocardial imaging showed patchy perfusion defect. Histological findings of the left ventricle demonstrated hypertrophy, degeneration and marked dysarray of the myocytes and fibrosis. MRI has the potential ability for the evaluation and sequential monitoring of myocardial tissue characterization as well as cardiac anatomy in childhood hypertrophic cardiomyopathy. (author).

  19. Spiral CT angiography (SCTA) study of celiac artery and superior mesenteric artery

    International Nuclear Information System (INIS)

    Yuan Zhenguo; Zhou Cunsheng; Xu Zuodong; Shi Hao; Wang Tao

    1999-01-01

    Objective: To study the visualization capability and scanning technique of SCTA in celiac artery, superior mesenteric artery (SMA) and other branches. Methods: Thirty patients, with normal abdominal SCTA results, were given small injection test dose after plain scan. The abdominal aorta parallel to the body of pancreas was chosen as target vessel, the peak-time plus 2 seconds as the best delay scan time. Iodine contrast medium 90∼110 ml was injected into antecubital vein at the speed of 3.5 ml/s, then scan from cranial to caudal was performed. Pitch 1.0 and slice thickness 3.2 mm were selected as the scan parameters. Maximum intensity projection (MaxIP) was employed in all patients and shaded surface display (SSD) in 23 cases. Results: The display rate using MaxIP and SSD of celiac artery, splenic artery, common hepatic artery, proper hepatic artery and SMA were all 100%, the gastroduodenal artery 100% and 91%, the left gastric artery 83% and 87%, respectively. Conclusions: SCTA as a minimally invasive examination is a valuable method to detect and diagnose disease or variations of celiac artery, its branches and SMA. Spiral scanning technique and image processing have a decisive effect on the image quality

  20. Fully Convolutional Architecture for Low-Dose CT Image Noise Reduction

    Science.gov (United States)

    Badretale, S.; Shaker, F.; Babyn, P.; Alirezaie, J.

    2017-10-01

    One of the critical topics in medical low-dose Computed Tomography (CT) imaging is how best to maintain image quality. As the quality of images decreases with lowering the X-ray radiation dose, improving image quality is extremely important and challenging. We have proposed a novel approach to denoise low-dose CT images. Our algorithm learns directly from an end-to-end mapping from the low-dose Computed Tomography images for denoising the normal-dose CT images. Our method is based on a deep convolutional neural network with rectified linear units. By learning various low-level to high-level features from a low-dose image the proposed algorithm is capable of creating a high-quality denoised image. We demonstrate the superiority of our technique by comparing the results with two other state-of-the-art methods in terms of the peak signal to noise ratio, root mean square error, and a structural similarity index.

  1. Superior temporal gyrus volume reduction and P300 in schizophrenia prior to treatment

    International Nuclear Information System (INIS)

    Hirayasu, Akira; Hokama, Hiroto; Ogura, Chikara; Ohta, Hirokazu; Arakaki, Hajime; Asato, Naohiko; Yamaguchi, Keiichiro

    1998-01-01

    Authors measured the superior temporal gyrus volume by 3D MRI imaging for the schizophrenics and simultaneously recorded the P300 component during the auditory odd-ball exercise. Subjects were 8 cases of schizophrenics and the sex- and age-matched healthy control adults. In schizophrenics, the superior temporal gyrus volume reduction was found. When the superior temporal gyrus was divided into two parts, the anterior part containing the primary auditory area, and the posterior part containing the planum temporale and the Wernicle speech area, the volume reduction of left side in the posterior part was remarkable. There was no difference in the latent time and the P300 amplitude between schizophrenics and healthy controls, suggesting that the superior temporal gyrus abnormalities will appear prior to P300 abnormalities. We could not find any correlation between findings of MRI and P300 and psychic symptoms. We discuss the possible contribution on the elucidation of the pathogenesis of the schizophrenia by simultaneous recordings of 3D MRI imaging and the event-related potentials. (K.H.)

  2. Traumatic cervical root injury: Diagnostic value of MR imaging

    International Nuclear Information System (INIS)

    Lee, Seon Kyu; Chang, Kee Hyun; Han, Moon Hee; Kim, Ho Chul; Kim, Jea Seung; Cha, Sang Hoon

    1993-01-01

    Although superior soft tissue contrast and direct multiplanar imaging capability of MRI are well recognized, myelography has been the imaging modality of choice in evaluation cervical root injury. We assessed the role of MRI and compared its diagnostic accuracy with myelography in the evaluation of cervical root injury. MR imagings of cervical root injury in ten patients (55 roots) were retrospectively reviewed. In 26 explored roots (6 patients). MR findings were compared with myelography and surgical results. In 29 roots (8 patients), which were confirmed by myelography or exploration, the MR findings were focal extradural CSF collections (pseudomeningocele) in 21/29 (72.4%, 8 patients), thickening of extradural roots in 4/29 (13.6%, 5 patients), and thickening of dura in 12/29 (41.4%, 6 patients) roots. T2-weighted axial image was superior to T1-weighted and protein-density- weighted images for delineation root avulsion. The sensitivity and specificity of MRI were 72.7% and 93.3% respectively, while those of myelography were 83% and 90%. Overall diagnostic accuracy of MRI and myelography were comparable (84.6% vs 87.5%). In conclusion, myelography is still considered as the modality of choice in the preoperative evaluation of the cervical root avulsion because of its higher sensitivity. MRI, however, may obviate the myelography with some technical refinements

  3. Readout-Segmented Echo-Planar Imaging in Diffusion-Weighted MR Imaging in Breast Cancer: Comparison with Single-Shot Echo-Planar Imaging in Image Quality

    International Nuclear Information System (INIS)

    Kim, Yun Ju; Kim, Sung Hun; Kang, Bong Joo; Park, Chang Suk; Kim, Hyeon Sook; Son, Yo Han; Porter, David Andrew; Song, Byung Joo

    2014-01-01

    The purpose of this study was to compare the image quality of standard single-shot echo-planar imaging (ss-EPI) and that of readout-segmented EPI (rs-EPI) in patients with breast cancer. Seventy-one patients with 74 breast cancers underwent both ss-EPI and rs-EPI. For qualitative comparison of image quality, three readers independently assessed the two sets of diffusion-weighted (DW) images. To evaluate geometric distortion, a comparison was made between lesion lengths derived from contrast enhanced MR (CE-MR) images and those obtained from the corresponding DW images. For assessment of image parameters, signal-to-noise ratio (SNR), lesion contrast, and contrast-to-noise ratio (CNR) were calculated. The rs-EPI was superior to ss-EPI in most criteria regarding the qualitative image quality. Anatomical structure distinction, delineation of the lesion, ghosting artifact, and overall image quality were significantly better in rs-EPI. Regarding the geometric distortion, lesion length on ss-EPI was significantly different from that of CE-MR, whereas there were no significant differences between CE-MR and rs-EPI. The rs-EPI was superior to ss-EPI in SNR and CNR. Readout-segmented EPI is superior to ss-EPI in the aspect of image quality in DW MR imaging of the breast

  4. Acquired image quality in digital industrial radiographic equipments

    International Nuclear Information System (INIS)

    Oliveira, Cristiane de Queiroz; Lopes, Ricardo Tadeu; Oliveira, Davi F.

    2008-01-01

    The computerized radiographic application in the industrial area is a recent event. The imaging plate is the equipment used as imaging receiver during the exposition radiographic technique, which consists of a flexible photostimulable phosphor screen, capable of storing the photons energy of the incident X and γ rays and of a reading unit which uses a laser device to stimulate a visible light. As two types of phosphor screen are manufactured, one for general use (General Plate - GP) and another one for specific using (High Resolution-HR), one of the objectives of this study was to evaluate the spatial resolution capability in both plates using the Kodak equipment. Furthermore, equipment from different makers, Kodak and General Electric Company - GE, were compared. Two phosphor screen HR were used as the main objective of this study. Imaging Quality Indicators - IQI were used to evaluate the spatial resolution of the images in accordance with ASME and DIN standard. The results show that after evaluating the GP and HR Kodak plates, the HR plate was capable of showing a larger resolution of details. However, after evaluating the performance of the HR Kodak plate and GE plate, over the same acquisition condition and with the same size of the laser focal set of 87 μm, the results show a superiority in the GE equipment used for industrial radiographic, mainly for processed images in each specific ambient of digital processing and its performance in meeting satisfactorily the ASME code and the DIN standard. (author)

  5. Image Simulation and Assessment of the Colour and Spatial Capabilities of the Colour and Stereo Surface Imaging System (CaSSIS) on the ExoMars Trace Gas Orbiter

    Science.gov (United States)

    Tornabene, Livio L.; Seelos, Frank P.; Pommerol, Antoine; Thomas, Nicholas; Caudill, C. M.; Becerra, Patricio; Bridges, John C.; Byrne, Shane; Cardinale, Marco; Chojnacki, Matthew; Conway, Susan J.; Cremonese, Gabriele; Dundas, Colin M.; El-Maarry, M. R.; Fernando, Jennifer; Hansen, Candice J.; Hansen, Kayle; Harrison, Tanya N.; Henson, Rachel; Marinangeli, Lucia; McEwen, Alfred S.; Pajola, Maurizio; Sutton, Sarah S.; Wray, James J.

    2018-02-01

    This study aims to assess the spatial and visible/near-infrared (VNIR) colour/spectral capabilities of the 4-band Colour and Stereo Surface Imaging System (CaSSIS) aboard the ExoMars 2016 Trace Grace Orbiter (TGO). The instrument response functions for the CaSSIS imager was used to resample spectral libraries, modelled spectra and to construct spectrally ( i.e., in I/F space) and spatially consistent simulated CaSSIS image cubes of various key sites of interest and for ongoing scientific investigations on Mars. Coordinated datasets from Mars Reconnaissance Orbiter (MRO) are ideal, and specifically used for simulating CaSSIS. The Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) provides colour information, while the Context Imager (CTX), and in a few cases the High-Resolution Imaging Science Experiment (HiRISE), provides the complementary spatial information at the resampled CaSSIS unbinned/unsummed pixel resolution (4.6 m/pixel from a 400-km altitude). The methodology used herein employs a Gram-Schmidt spectral sharpening algorithm to combine the ˜18-36 m/pixel CRISM-derived CaSSIS colours with I/F images primarily derived from oversampled CTX images. One hundred and eighty-one simulated CaSSIS 4-colour image cubes (at 18-36 m/pixel) were generated (including one of Phobos) based on CRISM data. From these, thirty-three "fully"-simulated image cubes of thirty unique locations on Mars ( i.e., with 4 colour bands at 4.6 m/pixel) were made. All simulated image cubes were used to test both the colour capabilities of CaSSIS by producing standard colour RGB images, colour band ratio composites (CBRCs) and spectral parameters. Simulated CaSSIS CBRCs demonstrated that CaSSIS will be able to readily isolate signatures related to ferrous (Fe2+) iron- and ferric (Fe3+) iron-bearing deposits on the surface of Mars, ices and atmospheric phenomena. Despite the lower spatial resolution of CaSSIS when compared to HiRISE, the results of this work demonstrate that Ca

  6. Capabilities and Impact on Wind Analyses of the Hurricane Imaging Radiometer (HIRAD)

    Science.gov (United States)

    Miller, Timothy L.; Amarin, Ruba; Atlas, Robert; Bailey, M. C.; Black, Peter; Buckley, Courtney; James, Mark; Johnson, James; Jones, Linwood; Ruf, Christopher; hide

    2010-01-01

    The Hurricane Imaging Radiometer (HIRAD) is a new airborne microwave remote sensor for hurricane observations that is currently under development by NASA Marshall Space Flight Center in partnership with the NOAA Atlantic Oceanographic and Meteorological Laboratory/Hurricane Research Division, the University of Central Florida, the University of Michigan, and the University of Alabama in Huntsville. The instrument is being test flown in January and is expected to participate in or collaborate with the tropical cyclone experiment GRIP (Genesis and Rapid Intensification Processes) in the 2010 season. HIRAD is designed to study the wind field in some detail within strong hurricanes and to enhance the real-time airborne ocean surface winds observation capabilities of NOAA and USAF Weather Squadron hurricane hunter aircraft currently using the operational Stepped Frequency Microwave Radiometer (SFMR). Unlike SFMR, which measures wind speed and rain rate along the ground track at a single point directly beneath the aircraft, HIRAD will provide images of the surface wind and rain field over a wide swath (approx.3 x the aircraft altitude) with approx.2 km resolution. See Figure 1, which depicts a simulated HIRAD swath versus the line of data obtained by SFMR.

  7. Sacroiliac joint injection using the posterior superior iliac spines as ...

    African Journals Online (AJOL)

    Limitations in the availability of such image guided techniques in health ... School of Medical Sciences, University of Science and Technology between 2006 and ... The needle position from the posterior superior iliac spine and its angle of ...

  8. Magnetic resonance imaging of lacunar infarcts in the basal ganglionic area

    International Nuclear Information System (INIS)

    Mukai, Kanji; Hondo, Hideki; Ueda, Shin; Matsumoto, Keizo

    1989-01-01

    During the previous 2 years, 88 patients have been diagnosed as having lacunar infarcts in the basal ganglioa ( a total of 157 lesions) on magnetic resonance imaging (MRI):42 patients had a single lesion and 46 patients had multiple lesions (2 lesions in 25 patients, 3 lesions in 14, and 4 or more lesions in 7). Seventy-seven lesions (49%) were smaller than 5 mm in diameter, and the others ranged from 5 mm to 15 mm. According to the regional relations to the internal capsule, the lesions were classified as lateral (57 lesions), anterior (36), superior (34), posterior (26), and inferior (4). Lesions of posterior, anterior, superior, and inferior types were associated with severer hemisparetic state, an abnormally slow gait, a sensory disturbance of numbness, and a depressive state, respectively. Forty five lesions (28%) were asymptomatic. Cat scanning failed to deliniate 47 lesions (30%) that were detected on MRI. Twenty three lesions were both asymptomatic and undistinguished on CT, which consisted of the superior type (10), anteior type (7), lateral type (5), and posterior type (one). Twenty four lesions were symptomatic, but were undistinguished on CT, suggesting that MRI is superior to CT in detecting the lacunar infarcts in the basal ganglionic area. Lacunar infarcts in both acute and chronic stages tended to be larger on T2-weighted images than T1-weighted images. In 7 patients who had neither history of hypertension, diabetes mellitus, or cardiac emboli nor CT evidence, MRI was capable of detecting lacunar infarcts. (N.K.)

  9. Temporal Bone Fracture Causing Superior Semicircular Canal Dehiscence

    Directory of Open Access Journals (Sweden)

    Kevin A. Peng

    2014-01-01

    Full Text Available Importance. Superior semicircular canal dehiscence (SCD is a third window lesion of the inner ear causing symptoms of vertigo, autophony, tinnitus, and hearing loss. A “two-hit” hypothesis has traditionally been proposed, whereby thinly developed bone overlying the superior canal is disrupted by a sudden change in intracranial pressure. Although the symptoms of SCD may be precipitated by head injury, no previous reports have described a temporal bone fracture directly causing SCD. Observations. Two patients sustained temporal bone fractures after closed head trauma, and developed unilateral otologic symptoms consistent with SCD. In each instance, computed tomography imaging revealed fractures extending through the bony roof of the superior semicircular canal. Conclusions and Relevance. Temporal bone fractures, which are largely treated nonoperatively, have not previously been reported to cause SCD. As it is a potentially treatable entity, SCD resulting from temporal bone fracture must be recognized as a possibility and diagnosed promptly if present.

  10. TH-AB-209-09: Quantitative Imaging of Electrical Conductivity by VHF-Induced Thermoacoustics

    Energy Technology Data Exchange (ETDEWEB)

    Patch, S; Hull, D [Avero Diagnostics, Irving, TX (United States); See, W [Medical College of Wisconsin, Milwaukee, WI (United States); Hanson, G [UW-Milwaukee, Milwaukee, WI (United States)

    2016-06-15

    Purpose: To demonstrate that very high frequency (VHF) induced thermoacoustics has the potential to provide quantitative images of electrical conductivity in Siemens/meter, much as shear wave elastography provides tissue stiffness in kPa. Quantitatively imaging a large organ requires exciting thermoacoustic pulses throughout the volume and broadband detection of those pulses because tomographic image reconstruction preserves frequency content. Applying the half-wavelength limit to a 200-micron inclusion inside a 7.5 cm diameter organ requires measurement sensitivity to frequencies ranging from 4 MHz down to 10 kHz, respectively. VHF irradiation provides superior depth penetration over near infrared used in photoacoustics. Additionally, VHF signal production is proportional to electrical conductivity, and prostate cancer is known to suppress electrical conductivity of prostatic fluid. Methods: A dual-transducer system utilizing a P4-1 array connected to a Verasonics V1 system augmented by a lower frequency focused single element transducer was developed. Simultaneous acquisition of VHF-induced thermoacoustic pulses by both transducers enabled comparison of transducer performance. Data from the clinical array generated a stack of 96-images with separation of 0.3 mm, whereas the single element transducer imaged only in a single plane. In-plane resolution and quantitative accuracy were measured at isocenter. Results: The array provided volumetric imaging capability with superior resolution whereas the single element transducer provided superior quantitative accuracy. Combining axial images from both transducers preserved resolution of the P4-1 array and improved image contrast. Neither transducer was sensitive to frequencies below 50 kHz, resulting in a DC offset and low-frequency shading over fields of view exceeding 15 mm. Fresh human prostates were imaged ex vivo and volumetric reconstructions reveal structures rarely seen in diagnostic images. Conclusion

  11. Cine computed tomography for diagnosis of superior vena cava obstruction following the mustard operation

    International Nuclear Information System (INIS)

    Matherne, G.P.; Atkins, D.L.; Frey, E.E.; Smith, W.L.

    1987-01-01

    Superior vena caval obstruction is a well described complication following Mustard's repair for transposition of the great arteries. We report a case of a 6-year-old child with superior vena cava obstruction correctly diagnosed by Cine-CT. The advantages of imaging with Cine-CT for this complication are discussed. (orig.)

  12. A secret-sharing-based method for authentication of grayscale document images via the use of the PNG image with a data repair capability.

    Science.gov (United States)

    Lee, Che-Wei; Tsai, Wen-Hsiang

    2012-01-01

    A new blind authentication method based on the secret sharing technique with a data repair capability for grayscale document images via the use of the Portable Network Graphics (PNG) image is proposed. An authentication signal is generated for each block of a grayscale document image, which, together with the binarized block content, is transformed into several shares using the Shamir secret sharing scheme. The involved parameters are carefully chosen so that as many shares as possible are generated and embedded into an alpha channel plane. The alpha channel plane is then combined with the original grayscale image to form a PNG image. During the embedding process, the computed share values are mapped into a range of alpha channel values near their maximum value of 255 to yield a transparent stego-image with a disguise effect. In the process of image authentication, an image block is marked as tampered if the authentication signal computed from the current block content does not match that extracted from the shares embedded in the alpha channel plane. Data repairing is then applied to each tampered block by a reverse Shamir scheme after collecting two shares from unmarked blocks. Measures for protecting the security of the data hidden in the alpha channel are also proposed. Good experimental results prove the effectiveness of the proposed method for real applications.

  13. Magnetic Resonance Imaging versus Computed Tomography and Different Imaging Modalities in Evaluation of Sinonasal Neoplasms Diagnosed by Histopathology

    Directory of Open Access Journals (Sweden)

    Mohammed A. Gomaa

    2013-01-01

    Full Text Available Objective The study purpose was to detect the value of magnetic resonance imaging (MRI compared to computed tomography (CT and different imaging modalities as conventional radiology in evaluation of sinonasal neoplasms diagnosed by Histopathology. Methods Thirty patients (16 males and 14 females were complaining of symptoms related to sinonasal tract. After thorough clinical and local examination, the patients were subjected to the following: conventional radiography, CT, MRI, and histopathological examination. Results The nasal cavity was the most commonly involved site with sinonasal malignancies followed by the maxillary sinuses. The least commonly affected site was the frontal sinuses. Benign sinonasal tumors were present in 14 cases. The most common benign lesion was juvenile nasopharyngeal angiofibroma (6 cases, followed by inverted papilloma (3 cases. While malignant sinonasal tumors were present in 16 cases, squamous cell carcinoma was present in 5 cases, and undifferentiated carcinoma, in 3 cases. Lymphoepithelioma and non-Hodgkin lymphomas were present in 2 cases each, while adenocarcinoma, chondrosarcoma, adenoid cystic carcinoma, and rhabdomyosarcoma were present in 1 case each. Conclusion MRI with its superior soft tissue contrast and multiplanar capability is superior to CT in pretreatment evaluation of primary malignant tumors of sinonasal cavity.

  14. Superior semicircular canal dehiscence in relation to the superior petrosal sinus: a potential cause of pulsatile tinnitus

    International Nuclear Information System (INIS)

    Liu, Z.; Bi, W.; Li, J.; Li, Q.; Dong, C.; Zhao, P.; Lv, H.; Wang, Z.

    2015-01-01

    Aim: To examine the association between superior semicircular canal dehiscence (SSCD) and pulsatile tinnitus (PT). Materials and methods: Two SSCD groups included 408 unilateral persistent PT patients, and 511 controls undergoing head and neck dual-phase contrast-enhanced computed tomography (DP-CECT) for reasons other than PT. The prevalence of type I (no the superior petrosal sinus running through the dehiscence) and type II (superior semicircular canal dehiscence in relation to the superior petrosal sinus) SSCD was analysed using chi-square test. Results: SSCD was identified in 5.1% (21/408) of PT ears, significantly different from 2% (8/408) of non-PT ears and 0.7% (7/1022) of controls. There was no significant difference in SSCD prevalence between non-PT ears in the PT group and controls. In the PT group, 15/21 ears were type II SSCD; 6/21 ears were type I. Fifteen combined non-PT and control ears with SSCD included two type II and 13 type I SSCD. The prevalence of type II SSCD in PT ears was significantly higher than that of non-PT ears in both groups, and the prevalence of type I SSCD in PT ears was similar to that of non-PT ears in both groups. Conclusion: Compared with type I SSCD, there may be a causal relationship between type II SSCD and PT. -- Highlights: •The prevalence of type II SSCD in PT ears was significantly higher than that in non-PT ears in both the PT group and controls. •The prevalence of type I SSCD was similar among the PT ears and non-PT ears. •The superior petrosal sinus running through the dehiscence may be essential for SSCD to induce PT. •Venous phase CT images with bone window settings is the modality method to differentiate type II from type I SSCD

  15. Ruptured superior gluteal artery pseudoaneurysm with hemorrhagic shock: Case report.

    Science.gov (United States)

    Corbacioglu, Kerem Seref; Aksel, Gokhan; Yildiz, Altan

    2016-03-01

    Pseudoaneurysm of the superior gluteal artery (SGA) is very rare and the most common causes are blunt or penetrating pelvic traumas. Although pseudoaneurysm can be asymptomatic at the time of initial trauma, it can be symptomatic weeks, months, even years after initial trauma. We present a case of a ruptured superior gluteal artery pseudoaneurysm with hemorrhagic shock twenty days after a bomb injury in the Syria civil war. In addition, we review the anatomy of the SGA, clinical presentation and pitfalls of pseudoaneurysm, and imaging and treatment options.

  16. Eutrophication monitoring for Lake Superior's Chequamegon ...

    Science.gov (United States)

    A priority for the Lake Superior CSMI was to identify susceptible nearshore eutrophication areas. We developed an integrated sampling design to collect baseline data for Lake Superior’s Chequamegon Bay to understand how nearshore physical processes and tributary loading relate to observed chlorophyll concentrations. Sampling included ship-based water samples combined with vertical CTD casts, continuous in situ towing and data collected from an autonomous underwater glider. Sampling was conducted during June, July and September. The glider collected regional data as part of three extended missions in Lake Superior over the same periods. During the study, two significant storm events impacted the western end of Lake Superior; the first occurred during July 11-12, with 8-10 inches of rain in 24hrs, and the second on July 21 with winds in excess of 161 km/h. Using GIS software, we organized these diverse temporal data sets along a continuous time line with temporally coincident Modis Satellite data to visualize surface sediment plumes in relation to water quality measurements. Preliminary results suggest that both events impacted regional water quality, and that nearshore physical forces (upwelling and currents) influenced the spatial variability. Results comparing in situ measures with remotely sensed images will be discussed. not applicable

  17. Origins of superior dynamic visual acuity in baseball players: superior eye movements or superior image processing.

    Directory of Open Access Journals (Sweden)

    Yusuke Uchida

    Full Text Available Dynamic visual acuity (DVA is defined as the ability to discriminate the fine parts of a moving object. DVA is generally better in athletes than in non-athletes, and the better DVA of athletes has been attributed to a better ability to track moving objects. In the present study, we hypothesized that the better DVA of athletes is partly derived from better perception of moving images on the retina through some kind of perceptual learning. To test this hypothesis, we quantitatively measured DVA in baseball players and non-athletes using moving Landolt rings in two conditions. In the first experiment, the participants were allowed to move their eyes (free-eye-movement conditions, whereas in the second they were required to fixate on a fixation target (fixation conditions. The athletes displayed significantly better DVA than the non-athletes in the free-eye-movement conditions. However, there was no significant difference between the groups in the fixation conditions. These results suggest that the better DVA of athletes is primarily due to an improved ability to track moving targets with their eyes, rather than to improved perception of moving images on the retina.

  18. Origins of superior dynamic visual acuity in baseball players: superior eye movements or superior image processing.

    Science.gov (United States)

    Uchida, Yusuke; Kudoh, Daisuke; Murakami, Akira; Honda, Masaaki; Kitazawa, Shigeru

    2012-01-01

    Dynamic visual acuity (DVA) is defined as the ability to discriminate the fine parts of a moving object. DVA is generally better in athletes than in non-athletes, and the better DVA of athletes has been attributed to a better ability to track moving objects. In the present study, we hypothesized that the better DVA of athletes is partly derived from better perception of moving images on the retina through some kind of perceptual learning. To test this hypothesis, we quantitatively measured DVA in baseball players and non-athletes using moving Landolt rings in two conditions. In the first experiment, the participants were allowed to move their eyes (free-eye-movement conditions), whereas in the second they were required to fixate on a fixation target (fixation conditions). The athletes displayed significantly better DVA than the non-athletes in the free-eye-movement conditions. However, there was no significant difference between the groups in the fixation conditions. These results suggest that the better DVA of athletes is primarily due to an improved ability to track moving targets with their eyes, rather than to improved perception of moving images on the retina.

  19. Magnetic resonance imaging in multiple sclerosis

    International Nuclear Information System (INIS)

    Kojima, Shigeyuki; Hirayama, Keizo

    1989-01-01

    Magnetic resonance imaging (MRI) of the brain was performed in a total of 45 patients with multiple sclerosis (MS), comprising 27 with brain symptoms and 18 without it. The results were compared with X-ray computed tomography (CT). Some of the 45 MS patients were also examined by neurophysiological studies for comparison. MRI showed demyelinating plaques of the brain in a total of 31 patients (69%) - 20 symptomatic and 11 asymptomatic patients. For symptomatic patients, MRI was capable of detecting brain lesions in 6 (86%) of 7 acute stage patients and 14 (70%) of 20 non-acute stage patients. It was also capable of detecting brain lesions in 21 (70%) of 30 clinically definite MR patients and 10 (67%) of 15 clinically probable MS patients. Concurrently available X-ray CT revealed brain lesions in 9 symptomatic patients (33%) and one asymptomatic patient (6%). Visual evoked potentials examined in 31 patients showed abnormality in one (11%) of 9 patients without symptoms of optic neuritis and all (100%) of the other 22 patients with symptoms. In 19 evaluable patients, auditory brainstem responses were abnormal in one (11%) of 9 patients without brainstem symptoms and 3 (30%) of 10 patients with symptoms. MRI of the brain was far superior to X-ray CT, visual evoked potentials and auditory brainstem responses in detecting clinically unsuspected lesions. We proposed new diagnostic criteria including MRI findings of the brain in the Japanese MS diagnostic criteria. MRI of the spinal cord was performed in 12 MS patients with spinal cord symptoms by sagittal and coronal images. It demonstrated demyelinating lesions within the cervical and superior thoracic cord in 8 MS acute stage patients. Spinal cord lesions were longitudinally continuous as long as many spinal segments, with swelling in 6 patients and atrophy in 2 patients. MRI of spinal cord was useful in deciding superior and inferior limits of cord lesions and in visualizing cord swelling or atrophy. (Namekawa, K)

  20. Experimental comparison of the high-speed imaging performance of an EM-CCD and sCMOS camera in a dynamic live-cell imaging test case.

    Directory of Open Access Journals (Sweden)

    Hope T Beier

    Full Text Available The study of living cells may require advanced imaging techniques to track weak and rapidly changing signals. Fundamental to this need is the recent advancement in camera technology. Two camera types, specifically sCMOS and EM-CCD, promise both high signal-to-noise and high speed (>100 fps, leaving researchers with a critical decision when determining the best technology for their application. In this article, we compare two cameras using a live-cell imaging test case in which small changes in cellular fluorescence must be rapidly detected with high spatial resolution. The EM-CCD maintained an advantage of being able to acquire discernible images with a lower number of photons due to its EM-enhancement. However, if high-resolution images at speeds approaching or exceeding 1000 fps are desired, the flexibility of the full-frame imaging capabilities of sCMOS is superior.

  1. Image simulation and assessment of the colour and spatial capabilities of the Colour and Stereo Surface Imaging System (CaSSIS) on the ExoMars Trace Gas Orbiter

    Science.gov (United States)

    Tornabene, Livio L.; Seelos, Frank P.; Pommerol, Antoine; Thomas, Nicolas; Caudill, Christy M.; Becerra, Patricio; Bridges, John C.; Byrne, Shane; Cardinale, Marco; Chojnacki, Matthew; Conway, Susan J.; Cremonese, Gabriele; Dundas, Colin M.; El-Maarry, M. R.; Fernando, Jennifer; Hansen, Candice J.; Hansen, Kayle; Harrison, Tanya N.; Henson, Rachel; Marinangeli, Lucia; McEwen, Alfred S.; Pajola, Maurizio; Sutton, Sarah S.; Wray, James J.

    2018-01-01

    This study aims to assess the spatial and visible/near-infrared (VNIR) colour/spectral capabilities of the 4-band Colour and Stereo Surface Imaging System (CaSSIS) aboard the ExoMars 2016 Trace Grace Orbiter (TGO). The instrument response functions for the CaSSIS imager was used to resample spectral libraries, modelled spectra and to construct spectrally (i.e., in I/F space) and spatially consistent simulated CaSSIS image cubes of various key sites of interest and for ongoing scientific investigations on Mars. Coordinated datasets from Mars Reconnaissance Orbiter (MRO) are ideal, and specifically used for simulating CaSSIS. The Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) provides colour information, while the Context Imager (CTX), and in a few cases the High-Resolution Imaging Science Experiment (HiRISE), provides the complementary spatial information at the resampled CaSSIS unbinned/unsummed pixel resolution (4.6 m/pixel from a 400-km altitude). The methodology used herein employs a Gram-Schmidt spectral sharpening algorithm to combine the ∼18–36 m/pixel CRISM-derived CaSSIS colours with I/F images primarily derived from oversampled CTX images. One hundred and eighty-one simulated CaSSIS 4-colour image cubes (at 18–36 m/pixel) were generated (including one of Phobos) based on CRISM data. From these, thirty-three “fully”-simulated image cubes of thirty unique locations on Mars (i.e., with 4 colour bands at 4.6 m/pixel) were made. All simulated image cubes were used to test both the colour capabilities of CaSSIS by producing standard colour RGB images, colour band ratio composites (CBRCs) and spectral parameters. Simulated CaSSIS CBRCs demonstrated that CaSSIS will be able to readily isolate signatures related to ferrous (Fe2+) iron- and ferric (Fe3+) iron-bearing deposits on the surface of Mars, ices and atmospheric phenomena. Despite the lower spatial resolution of CaSSIS when compared to HiRISE, the results of this work demonstrate that

  2. Satellite-based Tropical Cyclone Monitoring Capabilities

    Science.gov (United States)

    Hawkins, J.; Richardson, K.; Surratt, M.; Yang, S.; Lee, T. F.; Sampson, C. R.; Solbrig, J.; Kuciauskas, A. P.; Miller, S. D.; Kent, J.

    2012-12-01

    Satellite remote sensing capabilities to monitor tropical cyclone (TC) location, structure, and intensity have evolved by utilizing a combination of operational and research and development (R&D) sensors. The microwave imagers from the operational Defense Meteorological Satellite Program [Special Sensor Microwave/Imager (SSM/I) and the Special Sensor Microwave Imager Sounder (SSMIS)] form the "base" for structure observations due to their ability to view through upper-level clouds, modest size swaths and ability to capture most storm structure features. The NASA TRMM microwave imager and precipitation radar continue their 15+ yearlong missions in serving the TC warning and research communities. The cessation of NASA's QuikSCAT satellite after more than a decade of service is sorely missed, but India's OceanSat-2 scatterometer is now providing crucial ocean surface wind vectors in addition to the Navy's WindSat ocean surface wind vector retrievals. Another Advanced Scatterometer (ASCAT) onboard EUMETSAT's MetOp-2 satellite is slated for launch soon. Passive microwave imagery has received a much needed boost with the launch of the French/Indian Megha Tropiques imager in September 2011, basically greatly supplementing the very successful NASA TRMM pathfinder with a larger swath and more frequent temporal sampling. While initial data issues have delayed data utilization, current news indicates this data will be available in 2013. Future NASA Global Precipitation Mission (GPM) sensors starting in 2014 will provide enhanced capabilities. Also, the inclusion of the new microwave sounder data from the NPP ATMS (Oct 2011) will assist in mapping TC convective structures. The National Polar orbiting Partnership (NPP) program's VIIRS sensor includes a day night band (DNB) with the capability to view TC cloud structure at night when sufficient lunar illumination exits. Examples highlighting this new capability will be discussed in concert with additional data fusion efforts.

  3. Capabilities of diffusion-weighted and fresh blood imaging in depicting fresh thrombus. Presidential award proceedings

    International Nuclear Information System (INIS)

    Ando, Ritsuko; Manabe, Tsutomu; Tazawa, Satoru

    2007-01-01

    We examined the capabilities of diffusion-weighted (DWI) and fresh-blood imaging (FBI) in depicting thrombus. A paper-clay phantom holding test syringes of various sizes filled with either contrast medium or fresh human blood were scanned using a 1.5T magnetic resonance (MR) imaging unit, and apparent diffusion coefficient (ADC) values and signal intensities on DWI and FBI of the specimens were obtained. FBI depicted all the specimens regardless of syringe diameter, but DWI failed to image the syringe measuring 0.5 cm in diameter. B-factors and/or number of acquisitions (NAQ) seemed responsible for DWI's depiction capability. ADC values and signal intensities on DWI and FBI correlated with the viscosity of the contrast medium samples. Clotted blood, the most viscous of the samples, had the smallest ADC value and no relationship with signal intensities on DWI and FBI. Larger b-factors reduced signal intensity in contrast medium on DWI, but signals decreased only minimally in clotted blood. The result suggested that although viscosity was the influential factor for signal intensities on DWI in contrast medium, other factors, such as particle sizes of fibrin and hemoglobin, accounted for the low ADC values in clotting blood. T 2 relaxation time seemed to play a significant role in making signal intensities on DWI irrelevant to b-factors. Despite lapsed time, the clots were persistently hyperintense on FBI with a tendency to decrease only gradually. On DWI, there was a certain period when signal intensities were high and ADC values were low. The signal intensities on DWI and ADC values were considered to be influenced by the process of clot formation, and disappearance of signal seemed likely attributable to degeneration of protein and organization of the clot. (author)

  4. Superior Cervical Sympathetic Ganglion: Normal Imaging Appearance on 3T-MRI

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Joo Yeon; Lee, Jeong Hyun [Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul 05505 (Korea, Republic of); Song, Joon Seon; Song, Min Jeong [Department of Pathology, University of Ulsan College of Medicine, Asan Medical Center, Seoul 05505 (Korea, Republic of); Hwang, Seung-Jun [Department of Anatomy and Cell Biology, University of Ulsan College of Medicine, Asan Medical Center, Seoul 05505 (Korea, Republic of); Yoon, Ra Gyoung [Department of Radiology, Catholic Kwandong University International St. Mary' s Hospital, Catholic Kwandong University College of Medicine, Incheon 22711 (Korea, Republic of); Jang, Seung Won; Park, Ji Eun [Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul 05505 (Korea, Republic of); Heo, Young Jin [Department of Radiology, Busan Paik Hospital, Inje University College of Medicine, Busan 47392 (Korea, Republic of); Choi, Young Jun; Baek, Jung Hwan [Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul 05505 (Korea, Republic of)

    2016-11-01

    To identify superior cervical sympathetic ganglion (SCSG) and describe their characteristic MR appearance using 3T-MRI. In this prospective study, we recruited 53 consecutive patients without history of head and neck irradiation. Using anatomic location based on literature review, both sides of the neck were evaluated to identify SCSGs in consensus. SCSGs were divided into definite (medial to internal carotid artery [ICA] and lateral to longus capitis muscle [LCM]) and probable SCSGs based on relative location to ICA and LCM. Two readers evaluated signal characteristics including intraganglionic hypointensity of all SCSGs and relative location of probable SCSGs. Interrater and intrarater agreements were quantified using unweighted kappa. Ninety-one neck sites in 53 patients were evaluated after exclusion of 15 neck sites with pathology. Definite SCSGs were identified at 66 (73%) sites, and probable SCSGs were found in 25 (27%). Probable SCSGs were located anterior to LCM in 16 (18%), lateral to ICA in 6 (7%), and posterior to ICA in 3 (3%). Intraganglionic hypointensity was identified in 82 (90%) on contrast-enhanced fat-suppressed T1-weighted images. There was no statistical difference in the relative location between definite and probable SCSGs of the right and left sides with intragnalionic hypointensity on difference pulse sequences. Interrater and intrarater agreements on the location and intraganglionic hypointensity were excellent (κ-value, 0.749–1.000). 3T-MRI identified definite SCSGs at 73% of neck sites and varied location of the remaining SCSGs. Intraganglionic hypointensity was a characteristic feature of SCSGs.

  5. Superior cervical sympathetic ganglion: Normal imaging appearance on 3T-MRI

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Joo Yeon; Lee, Jeong Hyun; Song, Joon Seon [Dept. of Radiology, and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); and others

    2016-09-15

    To identify superior cervical sympathetic ganglion (SCSG) and describe their characteristic MR appearance using 3T-MRI. In this prospective study, we recruited 53 consecutive patients without history of head and neck irradiation. Using anatomic location based on literature review, both sides of the neck were evaluated to identify SCSGs in consensus. SCSGs were divided into definite (medial to internal carotid artery [ICA] and lateral to longus capitis muscle [LCM]) and probable SCSGs based on relative location to ICA and LCM. Two readers evaluated signal characteristics including intraganglionic hypointensity of all SCSGs and relative location of probable SCSGs. Interrater and intrarater agreements were quantified using unweighted kappa. Ninety-one neck sites in 53 patients were evaluated after exclusion of 15 neck sites with pathology. Definite SCSGs were identified at 66 (73%) sites, and probable SCSGs were found in 25 (27%). Probable SCSGs were located anterior to LCM in 16 (18%), lateral to ICA in 6 (7%), and posterior to ICA in 3 (3%). Intraganglionic hypointensity was identified in 82 (90%) on contrast-enhanced fat-suppressed T1-weighted images. There was no statistical difference in the relative location between definite and probable SCSGs of the right and left sides with intragnalionic hypointensity on difference pulse sequences. Interrater and intrarater agreements on the location and intraganglionic hypointensity were excellent (κ-value, 0.749–1.000). 3T-MRI identified definite SCSGs at 73% of neck sites and varied location of the remaining SCSGs. Intraganglionic hypointensity was a characteristic feature of SCSGs.

  6. Isolated abscess in superior rectus muscle in a child

    Directory of Open Access Journals (Sweden)

    Sushank Ashok Bhalerao

    2015-01-01

    Full Text Available Pyomyositis is a primary bacterial infection of striated muscles nearly always caused by Staphylococcus aureus. Development of the intramuscular abscess involving the extra-ocular muscles (EOMs remains an extremely rare process. We herein present a case of isolated EOM pyomyositis involving superior rectus muscle in a 2-year male child who was referred with complaints of swelling in left eye (LE and inability to open LE since last 1-month. Orbital computed tomography (CT scan showed a well-defined, hypo-dense, peripheral rim-enhancing lesion in relation to left superior rectus muscle suggestive of left superior rectus abscess. The abscess was drained through skin approach. We concluded that pyomyositis of EOM should be considered in any patient presenting with acute onset of orbital inflammation and characteristic CT or magnetic resonance imaging features. Management consists of incision and drainage coupled with antibiotic therapy.

  7. Secondary visual workload capability with primary visual and kinesthetic-tactual displays

    Science.gov (United States)

    Gilson, R. D.; Burke, M. W.; Jagacinski, R. J.

    1978-01-01

    Subjects performed a cross-adaptive tracking task with a visual secondary display and either a visual or a quickened kinesthetic-tactual (K-T) primary display. The quickened K-T display resulted in superior secondary task performance. Comparisons of secondary workload capability with integrated and separated visual displays indicated that the superiority of the quickened K-T display was not simply due to the elimination of visual scanning. When subjects did not have to perform a secondary task, there was no significant difference between visual and quickened K-T displays in performing a critical tracking task.

  8. Origins of Superior Dynamic Visual Acuity in Baseball Players: Superior Eye Movements or Superior Image Processing

    OpenAIRE

    Uchida, Yusuke; Kudoh, Daisuke; Murakami, Akira; Honda, Masaaki; Kitazawa, Shigeru

    2012-01-01

    Dynamic visual acuity (DVA) is defined as the ability to discriminate the fine parts of a moving object. DVA is generally better in athletes than in non-athletes, and the better DVA of athletes has been attributed to a better ability to track moving objects. In the present study, we hypothesized that the better DVA of athletes is partly derived from better perception of moving images on the retina through some kind of perceptual learning. To test this hypothesis, we quantitatively measured DV...

  9. Abnormal Degree Centrality of Bilateral Putamen and Left Superior Frontal Gyrus in Schizophrenia with Auditory Hallucinations: A Resting-state Functional Magnetic Resonance Imaging Study.

    Science.gov (United States)

    Chen, Cheng; Wang, Hui-Ling; Wu, Shi-Hao; Huang, Huan; Zou, Ji-Lin; Chen, Jun; Jiang, Tian-Zi; Zhou, Yuan; Wang, Gao-Hua

    2015-12-05

    Dysconnectivity hypothesis of schizophrenia has been increasingly emphasized. Recent researches showed that this dysconnectivity might be related to occurrence of auditory hallucination (AH). However, there is still no consistent conclusion. This study aimed to explore intrinsic dysconnectivity pattern of whole-brain functional networks at voxel level in schizophrenic with AH. Auditory hallucinated patients group (n = 42 APG), no hallucinated patients group (n = 42 NPG) and normal controls (n = 84 NCs) were analyzed by resting-state functional magnetic resonance imaging. The functional connectivity metrics index (degree centrality [DC]) across the entire brain networks was calculated and evaluated among three groups. DC decreased in the bilateral putamen and increased in the left superior frontal gyrus in all the patients. However, in APG, the changes of DC were more obvious compared with NPG. Symptomology scores were negatively correlated with the DC of bilateral putamen in all patients. AH score of APG positively correlated with the DC in left superior frontal gyrus but negatively correlated with the DC in bilateral putamen. Our findings corroborated that schizophrenia was characterized by functional dysconnectivity, and the abnormal DC in bilateral putamen and left superior frontal gyrus might be crucial in the occurrence of AH.

  10. Neural network application for thermal image recognition of low-resolution objects

    Science.gov (United States)

    Fang, Yi-Chin; Wu, Bo-Wen

    2007-02-01

    In the ever-changing situation on a battle field, accurate recognition of a distant object is critical to a commander's decision-making and the general public's safety. Efficiently distinguishing between an enemy's armoured vehicles and ordinary civilian houses under all weather conditions has become an important research topic. This study presents a system for recognizing an armoured vehicle by distinguishing marks and contours. The characteristics of 12 different shapes and 12 characters are used to explore thermal image recognition under the circumstance of long distance and low resolution. Although the recognition capability of human eyes is superior to that of artificial intelligence under normal conditions, it tends to deteriorate substantially under long-distance and low-resolution scenarios. This study presents an effective method for choosing features and processing images. The artificial neural network technique is applied to further improve the probability of accurate recognition well beyond the limit of the recognition capability of human eyes.

  11. Sustained attention is associated with right superior longitudinal fasciculus and superior parietal white matter microstructure in children

    DEFF Research Database (Denmark)

    Klarborg, Brith; Skak Madsen, Kathrine; Vestergaard, Martin

    2013-01-01

    Sustained attention develops during childhood and has been linked to the right fronto-parietal cortices in functional imaging studies; however, less is known about its relation to white matter (WM) characteristics. Here we investigated whether the microstructure of the WM underlying and connecting...... the right fronto-parietal cortices was associated with sustained attention performance in a group of 76 typically developing children aged 7-13 years. Sustained attention was assessed using a rapid visual information processing paradigm. The two behavioral measures of interest were the sensitivity index d......' and the coefficient of variation in reaction times (RT(CV) ). Diffusion-weighted imaging was performed. Mean fractional anisotropy (FA) was extracted from the WM underlying right dorsolateral prefrontal (DLPFC) and parietal cortex (PC), and the right superior longitudinal fasciculus (SLF), as well as equivalent...

  12. ISOPHOT - Capabilities and performance

    DEFF Research Database (Denmark)

    Lemke, D.; Klaas, U.; Abolins, J.

    1996-01-01

    ISOPHOT covers the largest wavelength range on ISO from 2.5 to 240 mu m. Its scientific capabilities include multi filter and multi-aperture photometry, polarimetry, imaging and spectrophotometry. All modes can optionally include a focal plane chopper. The backbone of the photometric calibration...

  13. Facile synthesis of carbon dots with superior sensing ability

    Science.gov (United States)

    Jin, Lin; Li, Jingguo; Liu, Liyun; Wang, Zhenling; Zhang, Xingcai

    2018-04-01

    Carbon dots (CDs) have various applications in biomedical and environmental field, such as bio-imaging, bio-sensing and heavy metal detection. In this study, a novel class of CDs were synthesized using a one-step hydrothermal method. The fabricated CDs displayed stable photoluminescence, good water solubility, and photo stability. Moreover, the functional groups (carboxylic acid moieties and hydroxyls) on the surface of the obtained CDs enable it with superior sensing ability (e.g., very low detectable concentration for Pb2+: 5 nmol/L). With superior detection sensitivity, excellent fluorescent properties and facile fabrication method, the as-obtained CDs can find practical applications as cost-effective and sensitive chemo-sensors in water and food safety field.

  14. Superiority of CT imaging reconstruction on Linux OS

    International Nuclear Information System (INIS)

    Lin Shaochun; Yan Xufeng; Wu Tengfang; Luo Xiaomei; Cai Huasong

    2010-01-01

    Objective: To compare the speed of CT reconstruction using the Linux and Windows OS. Methods: Shepp-Logan head phantom in different pixel size was projected to obtain the sinogram by using the inverse Fourier transformation, filtered back projection and Radon transformation on both Linux and Windows OS. Results: CT image reconstruction using the Linux operating system was significantly better and more efficient than Windows. Conclusion: CT image reconstruction using the Linux operating system is more efficient. (authors)

  15. Crystal and source characterization for the Crystal Backlighter Imager capability at the National Ignition Facility

    Science.gov (United States)

    Krauland, C. M.; Hall, G. N.; Buscho, J. G.; Hibbard, R.; McCarville, T. J.; Lowe-Webb, R.; Ayers, S. L.; Kalantar, D.; Kohut, T.; Kemp, G. E.; Bradley, D. K.; Bell, P.; Landen, O. L.; Brewster, T. N.; Piston, K.

    2017-10-01

    The Crystal Backlighter Imager (CBI) is a very narrow bandwidth ( 10 eV) x-ray radiography system that uses Bragg reflection from a spherically-curved crystal at near normal incidence. This diagnostic has the capability to image late in an ICF implosion because it only requires the brightness of the backlighter to be larger than the capsule self-emission in that narrow bandwidth. While the limited bandwidth is advantageous for this reason, it also requires that the effective energy of the backlighter atomic line is known to 1 eV accuracy for proper crystal alignment. Any Doppler shift in the line energy must be understood for the imaging system to work. The work presented details characterization experiments done at the Jupiter Laser Facility with a Si (8 6 2) crystal that will be used with a Selenium backlighter in the NIF CBI diagnostic. We used the spherically-bent crystals to image a small ( 200 µm) He α source generated by the Janus laser on a Se foil. Scanning Bragg angles over multiple shots allowed us to map out the spectral line intensity distribution for optimal alignment in NIF. A subsequent Doppler shift measurement using CBI on NIF will also be presented with complementary HYDRA modeling for both experiments. Prepared by LLNL under Contract DE-AC52-07NA27344 and by General Atomics under Contract DE-NA0001808.

  16. Optimal steel thickness combined with computed radiography for portal imaging of nasopharyngeal cancer patients

    International Nuclear Information System (INIS)

    Wu Shixiu; Jin Xiance; Xie Congying; Cao Guoquan

    2005-01-01

    The poor image quality of conventional metal screen-film portal imaging system has long been of concern, and various methods have been investigated in an attempt to enhance the quality of portal images. Computed radiography (CR) used in combination with a steel plate displays image enhancement. The optimal thickness of the steel plate had been studied by measuring the modulation transfer function (MTF) characteristics. Portal images of nasopharyngeal carcinoma patients were taken by both a conventional metal screen-film system and this optimal steel and CR plate combination system. Compared with a conventional metal screen-film system, the CR-metal screen system achieves a much higher image contrast. The measured modulation transfer function (MTF) of the CR combination is greater than conventional film-screen portal imaging systems and also results in superior image performance, as demonstrated by receiver operator characteristic (ROC) analysis. This optimal combination steel CR plate portal imaging system is capable of producing high contrast portal images conveniently

  17. Development, Capabilities, and Impact on Wind Analyses of the Hurricane Imaging Radiometer (HIRAD)

    Science.gov (United States)

    Miller, T.; Amarin, R.; Atlas, R.; Bailey, M.; Black, P.; Buckley, C.; Chen, S.; El-Nimri, S.; Hood, R.; James, M.; hide

    2010-01-01

    The Hurricane Imaging Radiometer (HIRAD) is a new airborne microwave remote sensor for hurricane observations that is currently under development by NASA Marshall Space Flight Center in partnership with the NOAA Atlantic Oceanographic and Meteorological Laboratory/Hurricane Research Division, the University of Central Florida, the University of Michigan, and the University of Alabama in Huntsville. The instrument is being test flown in January and is expected to participate in the tropical cyclone experiment GRIP (Genesis and Rapid Intensification Processes) in the 2010 season. HIRAD is being designed to study the wind field in some detail within strong hurricanes and to enhance the real-time airborne ocean surface winds observation capabilities of NOAA and USAF Weather Squadron hurricane hunter aircraft currently using the operational Stepped Frequency Microwave Radiometer (SFMR). Unlike SFMR, which measures wind speed and rain rate along the ground track at a single point directly beneath the aircraft, HIRAD will provide images of the surface wind and rain field over a wide swath (approximately 3 x the aircraft altitude) with approximately 2 km resolution. This paper describes the HIRAD instrument and the physical basis for its operations, including chamber test data from the instrument. The potential value of future HIRAD observations will be illustrated with a summary of Observing System Simulation Experiments (OSSEs) in which measurements from the new instrument as well as those from existing instruments (air, surface, and space-based) are simulated from the output of a detailed numerical model, and those results are used to construct simulated H*Wind analyses. Evaluations will be presented on the impact on H*Wind analyses of using the HIRAD instrument observations to replace those of the SFMR instrument, and also on the impact of a future satellite-based HIRAD in comparison to instruments with more limited capabilities for observing strong winds through heavy

  18. Enlarged right superior temporal gyrus in children and adolescents with autism.

    Science.gov (United States)

    Jou, Roger J; Minshew, Nancy J; Keshavan, Matcheri S; Vitale, Matthew P; Hardan, Antonio Y

    2010-11-11

    The superior temporal gyrus has been implicated in language processing and social perception. Therefore, anatomical abnormalities of this structure may underlie some of the deficits observed in autism, a severe neurodevelopmental disorder characterized by impairments in social interaction and communication. In this study, volumes of the left and right superior temporal gyri were measured using magnetic resonance imaging obtained from 18 boys with high-functioning autism (mean age=13.5±3.4years; full-scale IQ=103.6±13.4) and 19 healthy controls (mean age=13.7±3.0years; full-scale IQ=103.9±10.5), group-matched on age, gender, and handedness. When compared to the control group, right superior temporal gyral volumes was significantly increased in the autism group after controlling for age and total brain volume. There was no significant difference in the volume of the left superior temporal gyrus. Post-hoc analysis revealed a significant increase of the right posterior superior temporal gyral volume in the autism group, before and after controlling for age and total brain volume. Examination of the symmetry index for the superior temporal gyral volumes did not yield statistically significant between-group differences. Findings from this preliminary investigation suggest the existence of volumetric alterations in the right superior temporal gyrus in children and adolescents with autism, providing support for a neuroanatomical basis of the social perceptual deficits characterizing this severe neurodevelopmental disorder. Copyright © 2010 Elsevier B.V. All rights reserved.

  19. Diagnostic imaging capabilities of the Ocelot -Optical Coherence Tomography System, ex-vivo evaluation and clinical relevance

    International Nuclear Information System (INIS)

    Dohad, Suhail; Shao, John; Cawich, Ian; Kankaria, Manish; Desai, Arjun

    2015-01-01

    consistent physician interpretation of images acquired by the Ocelot and the Dragonfly OCT systems in-spite of distinct image processing algorithms and catheter configurations. This represents a dramatic shift away from both fluoroscopic imaging and diagnostic-only OCT imaging during peripheral arterial intervention towards therapeutic devices that incorporate real time diagnostic OCT imaging. In the clinical practice, these diagnostic capabilities have translated to best-in-class safety and efficacy for CTO crossing using the Ocelot catheter

  20. Pathologic and post-operative conditions of the plantar fascia: review of MR imaging appearances

    Energy Technology Data Exchange (ETDEWEB)

    Yu, J.S. [Ohio State Univ., Columbus (United States). Dept. of Radiology

    2000-09-01

    Magnetic resonance (MR) imaging has emerged as an important noninvasive diagnostic imaging technique for assessment of foot pathology. This modality, owing to its multiplanar imaging capability and inherent superiority in contrast, has been shown to be more accurate and sensitive for detection of plantar fascia pathology than any other imaging method. One of the most important and recognizable causes of heel pain is plantar fasciitis. With the exception of plantar fasciitis, there has been little emphasis on imaging other conditions that affect this important structure. The objective of this review is to demonstrate, from a perspective of MR imaging, the many different pathologic conditions that affect the plantar fascia. Included in this review will be a discussion of normal anatomy as well as entities such as acute plantar fasciitis, chronic plantar fasciitis, traumatic rupture, normal post-surgical changes, pathologic post-fasciotomy conditions, infection, and fibromatosis. (orig.)

  1. Pathologic and post-operative conditions of the plantar fascia: review of MR imaging appearances

    International Nuclear Information System (INIS)

    Yu, J.S.

    2000-01-01

    Magnetic resonance (MR) imaging has emerged as an important noninvasive diagnostic imaging technique for assessment of foot pathology. This modality, owing to its multiplanar imaging capability and inherent superiority in contrast, has been shown to be more accurate and sensitive for detection of plantar fascia pathology than any other imaging method. One of the most important and recognizable causes of heel pain is plantar fasciitis. With the exception of plantar fasciitis, there has been little emphasis on imaging other conditions that affect this important structure. The objective of this review is to demonstrate, from a perspective of MR imaging, the many different pathologic conditions that affect the plantar fascia. Included in this review will be a discussion of normal anatomy as well as entities such as acute plantar fasciitis, chronic plantar fasciitis, traumatic rupture, normal post-surgical changes, pathologic post-fasciotomy conditions, infection, and fibromatosis. (orig.)

  2. Pictorial Superiority Effect

    Science.gov (United States)

    Nelson, Douglas L.; And Others

    1976-01-01

    Pictures generally show superior recognition relative to their verbal labels. This experiment was designed to link this pictorial superiority effect to sensory or meaning codes associated with the two types of symbols. (Editor)

  3. Diagnosis of superior labral lesions: comparison of noncontrast MRI with indirect MR arthrography in unexercised shoulders

    International Nuclear Information System (INIS)

    Dinauer, Philip A.; Flemming, Donald J.; Murphy, Kevin P.; Doukas, William C.

    2007-01-01

    To prospectively compare the accuracy of noncontrast magnetic resonance imaging (MRI) with indirect MR arthrography (I-MRa) of unexercised shoulders for diagnosis of superior glenoid labral lesions. Institutional Review Board approval and patient informed consent were obtained for this prospective study. Superior labral findings on shoulder MRI and unexercised I-MRa studies of 104 patients were correlated with findings at arthroscopic shoulder surgery. Two musculoskeletal radiologists independently reviewed the two sets of MR images while blinded to arthroscopic results. For each radiologist, the McNemar test was used to detect statistically significant differences between techniques. The superior labrum was intact in 24 and abnormal in 80 subjects. For detection of superior labral lesions by each radiologist, I-MRa was more sensitive (84-91%) than MRI (66-85%), with statistically significant improvement in sensitivity for one reader (p = 0.003). However, I-MRa was less specific (58-71%) than MRI (75-83%). Overall, accuracy was slightly improved on I-MRa (78-86%) compared with MRI (70-83%), but this difference was not statistically significant for either reader. Compared with noncontrast MRI, I-MRa was more sensitive for diagnosis of superior glenoid labral lesions. However, the diagnostic value of I-MRa in shoulders remaining at rest is potentially limited by decreased specificity of the technique. (orig.)

  4. Invisibility cloak with image projection capability.

    Science.gov (United States)

    Banerjee, Debasish; Ji, Chengang; Iizuka, Hideo

    2016-12-13

    Investigations of invisibility cloaks have been led by rigorous theories and such cloak structures, in general, require extreme material parameters. Consequently, it is challenging to realize them, particularly in the full visible region. Due to the insensitivity of human eyes to the polarization and phase of light, cloaking a large object in the full visible region has been recently realized by a simplified theory. Here, we experimentally demonstrate a device concept where a large object can be concealed in a cloak structure and at the same time any images can be projected through it by utilizing a distinctively different approach; the cloaking via one polarization and the image projection via the other orthogonal polarization. Our device structure consists of commercially available optical components such as polarizers and mirrors, and therefore, provides a significant further step towards practical application scenarios such as transparent devices and see-through displays.

  5. Magnetic Particle Imaging for Real-Time Perfusion Imaging in Acute Stroke.

    Science.gov (United States)

    Ludewig, Peter; Gdaniec, Nadine; Sedlacik, Jan; Forkert, Nils D; Szwargulski, Patryk; Graeser, Matthias; Adam, Gerhard; Kaul, Michael G; Krishnan, Kannan M; Ferguson, R Matthew; Khandhar, Amit P; Walczak, Piotr; Fiehler, Jens; Thomalla, Götz; Gerloff, Christian; Knopp, Tobias; Magnus, Tim

    2017-10-24

    The fast and accurate assessment of cerebral perfusion is fundamental for the diagnosis and successful treatment of stroke patients. Magnetic particle imaging (MPI) is a new radiation-free tomographic imaging method with a superior temporal resolution, compared to other conventional imaging methods. In addition, MPI scanners can be built as prehospital mobile devices, which require less complex infrastructure than computed tomography (CT) and magnetic resonance imaging (MRI). With these advantages, MPI could accelerate the stroke diagnosis and treatment, thereby improving outcomes. Our objective was to investigate the capabilities of MPI to detect perfusion deficits in a murine model of ischemic stroke. Cerebral ischemia was induced by inserting of a microfilament in the internal carotid artery in C57BL/6 mice, thereby blocking the blood flow into the medial cerebral artery. After the injection of a contrast agent (superparamagnetic iron oxide nanoparticles) specifically tailored for MPI, cerebral perfusion and vascular anatomy were assessed by the MPI scanner within seconds. To validate and compare our MPI data, we performed perfusion imaging with a small animal MRI scanner. MPI detected the perfusion deficits in the ischemic brain, which were comparable to those with MRI but in real-time. For the first time, we showed that MPI could be used as a diagnostic tool for relevant diseases in vivo, such as an ischemic stroke. Due to its shorter image acquisition times and increased temporal resolution compared to that of MRI or CT, we expect that MPI offers the potential to improve stroke imaging and treatment.

  6. (Mis)placed central venous catheter in the left superior intercostal vein

    International Nuclear Information System (INIS)

    Padovan, Ranka Stern; Paar, Maja Hrabak; Aurer, Igor

    2010-01-01

    Chest X-ray is routinely performed to check the position of the central venous catheter (CVC) inserted through the internal jugular or subclavian vein, while the further evaluation of CVC malfunction is usually performed by contrast venography. In patients with superior vena cava obstruction, the tip of the catheter is often seen in collateral mediastinal venous pathways, rather than in the superior vena cava. In such cases detailed knowledge of thoracic vessel anatomy is necessary to identify the exact location of the catheter. We report a case of 32-year-old female patient with relapsing mediastinal lymphoma and previous superior vena cava obstruction with collateral azygos-hemiazygos venous pathways. The patient had CVC inserted through the left subclavian vein and its position was detected by CT to be in the dilated left superior intercostal vein and accessory hemiazygos vein. Considering that dilated accessory hemiazygos vein can tolerate infusion, the CVC was left in place and the patient had no complaints related to CVC (mal)position. Furthermore, we present anatomical and radiological observations on the azygos-hemiazygos venous system with the special emphasis on the left superior intercostal vein. Non-contrast CT scans can be a valuable imaging tool in the detection of the CVC position, especially in patients with renal insufficiency and contrast media hypersensitivity

  7. Application of the EM algorithm to radiographic images.

    Science.gov (United States)

    Brailean, J C; Little, D; Giger, M L; Chen, C T; Sullivan, B J

    1992-01-01

    The expectation maximization (EM) algorithm has received considerable attention in the area of positron emitted tomography (PET) as a restoration and reconstruction technique. In this paper, the restoration capabilities of the EM algorithm when applied to radiographic images is investigated. This application does not involve reconstruction. The performance of the EM algorithm is quantitatively evaluated using a "perceived" signal-to-noise ratio (SNR) as the image quality metric. This perceived SNR is based on statistical decision theory and includes both the observer's visual response function and a noise component internal to the eye-brain system. For a variety of processing parameters, the relative SNR (ratio of the processed SNR to the original SNR) is calculated and used as a metric to compare quantitatively the effects of the EM algorithm with two other image enhancement techniques: global contrast enhancement (windowing) and unsharp mask filtering. The results suggest that the EM algorithm's performance is superior when compared to unsharp mask filtering and global contrast enhancement for radiographic images which contain objects smaller than 4 mm.

  8. Visual search for emotional expressions: Effect of stimulus set on anger and happiness superiority.

    Science.gov (United States)

    Savage, Ruth A; Becker, Stefanie I; Lipp, Ottmar V

    2016-01-01

    Prior reports of preferential detection of emotional expressions in visual search have yielded inconsistent results, even for face stimuli that avoid obvious expression-related perceptual confounds. The current study investigated inconsistent reports of anger and happiness superiority effects using face stimuli drawn from the same database. Experiment 1 excluded procedural differences as a potential factor, replicating a happiness superiority effect in a procedure that previously yielded an anger superiority effect. Experiments 2a and 2b confirmed that image colour or poser gender did not account for prior inconsistent findings. Experiments 3a and 3b identified stimulus set as the critical variable, revealing happiness or anger superiority effects for two partially overlapping sets of face stimuli. The current results highlight the critical role of stimulus selection for the observation of happiness or anger superiority effects in visual search even for face stimuli that avoid obvious expression related perceptual confounds and are drawn from a single database.

  9. Assessment of cold neutron radiography capability

    International Nuclear Information System (INIS)

    McDonald, T.E. Jr.; Roberts, J.A.

    1998-01-01

    This is the final report of a one-year, Laboratory Directed Research and Development (LDRD) project at Los Alamos National Laboratory (LANL). The authors goals were to demonstrate and assess cold neutron radiography techniques at the Los Alamos Neutron Science Center (LANSCE), Manual Lujan Neutron Scattering Center (Lujan Center), and to investigate potential applications of the capability. The authors have obtained images using film and an amorphous silicon detector. In addition, a new technique they have developed allows neutron radiographs to be made using only a narrow range of neutron energies. Employing this approach and the Bragg cut-off phenomena in certain materials, they have demonstrated material discrimination in radiography. They also demonstrated the imaging of cracks in a sample of a fire-set case that was supplied by Sandia National Laboratory, and they investigated whether the capability could be used to determine the extent of coking in jet engine nozzles. The LANSCE neutron radiography capability appears to have applications in the DOE stockpile maintenance and science-based stockpile stewardship (SBSS) programs, and in industry

  10. Nanoarchitectured current collector for high rate capability of polyaniline based supercapacitor electrode

    International Nuclear Information System (INIS)

    Sumboja, Afriyanti; Wang Xu; Yan Jian; Lee, Pooi See

    2012-01-01

    Highlights: ► Preparation of organic/inorganic coaxial nanowires. ► Modifying current collector to improve both capacitance and rate capability simultaneously. ► Improvement in the charge transport process resulted in the superior rate capability. - Abstract: Indium tin oxide (ITO) nanowires array was used as current collector and building block for polyaniline based supercapacitor. Thin polyaniline coating was deposited on the nanowires and resulted in the formation of polyaniline ITO coaxial nanowires. This hybrid heterostructure design improved the specific capacitance, rate capability, and cycling stability of the supercapacitor electrode. Good conductivity harnessed by these directly grown ITO nanowires is useful to improve the charge transport during the charge discharge processes which were confirmed by the electrochemical impedance spectroscopy measurement. Electrochemical test in 1 M H 2 SO 4 at 4 A g −1 delivered specific capacitance as high as 738 F g −1 . In addition, sub-micron size of the intercoaxial nanowires spacing ensures the fast penetration of electrolyte ions which resulted in the superior rate capability (98% capacitance retention when applied current was varied from 4 to 25 A g −1 ). The capacitance retention is significantly higher as compared to other polyaniline composite electrodes and it is one of the best reported performances to date for polyaniline based supercapacitor electrodes. This work illustrates a promising platform that can be adopted for other redox nanocomposite materials while reaping the benefit as low cost and binder free electrode material for supercapacitor application.

  11. Data fusion in X-ray computed tomography using a superiorization approach.

    Science.gov (United States)

    Schrapp, Michael J; Herman, Gabor T

    2014-05-01

    X-ray computed tomography (CT) is an important and widespread inspection technique in industrial non-destructive testing. However, large-sized and heavily absorbing objects cause artifacts due to either the lack of penetration of the specimen in specific directions or by having data from only a limited angular range of views. In such cases, valuable information about the specimen is not revealed by the CT measurements alone. Further imaging modalities, such as optical scanning and ultrasonic testing, are able to provide data (such as an edge map) that are complementary to the CT acquisition. In this paper, a superiorization approach (a newly developed method for constrained optimization) is used to incorporate the complementary data into the CT reconstruction; this allows precise localization of edges that are not resolvable from the CT data by itself. Superiorization, as presented in this paper, exploits the fact that the simultaneous algebraic reconstruction technique (SART), often used for CT reconstruction, is resilient to perturbations; i.e., it can be modified to produce an output that is as consistent with the CT measurements as the output of unmodified SART, but is more consistent with the complementary data. The application of this superiorized SART method to measured data of a turbine blade demonstrates a clear improvement in the quality of the reconstructed image.

  12. Superior Canal Dehiscence Syndrome Affecting 3 Families.

    Science.gov (United States)

    Heidenreich, Katherine D; Kileny, Paul R; Ahmed, Sameer; El-Kashlan, Hussam K; Melendez, Tori L; Basura, Gregory J; Lesperance, Marci M

    2017-07-01

    Superior canal dehiscence syndrome (SCDS) is an increasingly recognized cause of hearing loss and vestibular symptoms, but the etiology of this condition remains unknown. To describe 7 cases of SCDS across 3 families. This retrospective case series included 7 patients from 3 different families treated at a neurotology clinic at a tertiary academic medical center from 2010 to 2014. Patients were referred by other otolaryngologists or were self-referred. Each patient demonstrated unilateral or bilateral SCDS or near dehiscence. Clinical evaluation involved body mass index calculation, audiometry, cervical vestibular evoked myogenic potential testing, electrocochleography, and multiplanar computed tomographic (CT) scan of the temporal bones. Zygosity testing was performed on twin siblings. The diagnosis of SCDS was made if bone was absent over the superior semicircular canal on 2 consecutive CT images, in addition to 1 physiologic sign consistent with labyrinthine dehiscence. Near dehiscence was defined as absent bone on only 1 CT image but with symptoms and at least 1 physiologic sign of labyrinthine dehiscence. A total of 7 patients (5 female and 2 male; age range, 8-49 years) from 3 families underwent evaluation. Family A consisted of 3 adult first-degree relatives, of whom 2 were diagnosed with SCDS and 1 with near dehiscence. Family B included a mother and her child, both of whom were diagnosed with unilateral SCDS. Family C consisted of adult monozygotic twins, each of whom was diagnosed with unilateral SCDS. For all cases, dehiscence was located at the arcuate eminence. Obesity alone did not explain the occurrence of SCDS because 5 of the 7 cases had a body mass index (calculated as weight in kilograms divided by height in meters squared) less than 30.0. Superior canal dehiscence syndrome is a rare, often unrecognized condition. This report of 3 multiplex families with SCDS provides evidence in support of a potential genetic contribution to the etiology

  13. Quantitative image reconstruction for total-body PET imaging using the 2-meter long EXPLORER scanner

    Science.gov (United States)

    Zhang, Xuezhu; Zhou, Jian; Cherry, Simon R.; Badawi, Ramsey D.; Qi, Jinyi

    2017-03-01

    The EXPLORER project aims to build a 2 meter long total-body PET scanner, which will provide extremely high sensitivity for imaging the entire human body. It will possess a range of capabilities currently unavailable to state-of-the-art clinical PET scanners with a limited axial field-of-view. The huge number of lines-of-response (LORs) of the EXPLORER poses a challenge to the data handling and image reconstruction. The objective of this study is to develop a quantitative image reconstruction method for the EXPLORER and compare its performance with current whole-body scanners. Fully 3D image reconstruction was performed using time-of-flight list-mode data with parallel computation. To recover the resolution loss caused by the parallax error between crystal pairs at a large axial ring difference or transaxial radial offset, we applied an image domain resolution model estimated from point source data. To evaluate the image quality, we conducted computer simulations using the SimSET Monte-Carlo toolkit and XCAT 2.0 anthropomorphic phantom to mimic a 20 min whole-body PET scan with an injection of 25 MBq 18F-FDG. We compare the performance of the EXPLORER with a current clinical scanner that has an axial FOV of 22 cm. The comparison results demonstrated superior image quality from the EXPLORER with a 6.9-fold reduction in noise standard deviation comparing with multi-bed imaging using the clinical scanner.

  14. Chemical Exchange Saturation Transfer MR Imaging Is Superior to Diffusion Tensor Imaging in the Diagnosis and Severity Evaluation of Parkinson's Disease: a Study on Substantia Nigra and Striatum

    Directory of Open Access Journals (Sweden)

    Chunmei eLi

    2015-10-01

    Full Text Available Parkinson’s disease (PD is a neurodegenerative disorder characterized by nigrostriatal cell loss. To date the diagnosis of PD is still based primarily on the clinical manifestations which may be typical and obvious only in advanced-stage PD. Thus, it is crucial to find a reliable marker for the diagnosis of PD. We conducted this study to assess the diagnostic efficiency of chemical-exchange-saturation-transfer (CEST imaging and diffusion-tensor imaging (DTI in PD at 3 Tesla by evaluating changes on substantia nigra and striatum. Twenty-three PD patients and twenty-three age-matched normal controls were recruited. All patients and controls were imaged on a 3 Tesla MR system, using an 8-channel head coil. CEST imaging was acquired in two transverse slices of the head, including substantia nigra and striatum. The magnetization-transfer-ratio asymmetry at 3.5 ppm, MTRasym(3.5ppm, and the total CEST signal intensity between 0 and 4 ppm were calculated. Multi-slice DTI was acquired for all the patients and normal controls. Quantitative analysis was performed on the substantia nigra, globus pallidus, putamen and caudate. The MTRasym(3.5ppm value, the total CEST signal intensity and fractional anisotropy (FA value of the substantia nigra were all significantly lower in PD patients than in normal controls (P = 0.003, P = 0.004 and P < 0.001, respectively. The MTRasym(3.5ppm values of the putamen and the caudate were significantly higher in PD patients than in normal controls (P = 0.010 and P = 0.009, respectively. There were no significant differences for the mean diffusivity (MD in these four regions between PD patients and normal controls. In conclusion, CEST MR imaging provided multiple CEST image contrasts in the substantia nigra and the striatum in PD and may be superior to DTI in the diagnosis of PD.

  15. Evaluation of state-of-the-art imaging systems for in vivo monitoring of retinal structure in mice: current capabilities and limitations

    Science.gov (United States)

    Zhang, Pengfei; Zam, Azhar; Pugh, Edward N.; Zawadzki, Robert J.

    2014-02-01

    Animal models of human diseases play an important role in studying and advancing our understanding of these conditions, allowing molecular level studies of pathogenesis as well as testing of new therapies. Recently several non-invasive imaging modalities including Fundus Camera, Scanning Laser Ophthalmoscopy (SLO) and Optical Coherence Tomography (OCT) have been successfully applied to monitor changes in the retinas of the living animals in experiments in which a single animal is followed over a portion of its lifespan. Here we evaluate the capabilities and limitations of these three imaging modalities for visualization of specific structures in the mouse eye. Example images acquired from different types of mice are presented. Future directions of development for these instruments and potential advantages of multi-modal imaging systems are discussed as well.

  16. Language development at 2 years is correlated to brain microstructure in the left superior temporal gyrus at term equivalent age: a diffusion tensor imaging study.

    Science.gov (United States)

    Aeby, Alec; De Tiège, Xavier; Creuzil, Marylise; David, Philippe; Balériaux, Danielle; Van Overmeire, Bart; Metens, Thierry; Van Bogaert, Patrick

    2013-09-01

    This study aims at testing the hypothesis that neurodevelopmental abilities at age 2 years are related with local brain microstructure of preterm infants at term equivalent age. Forty-one preterm infants underwent brain MRI with diffusion tensor imaging sequences to measure mean diffusivity (MD), fractional anisotropy (FA), longitudinal and transverse diffusivity (λ// and λ[perpendicular]) at term equivalent age. Neurodevelopment was assessed at 2 years corrected age using the Bayley III scale. A voxel-based analysis approach, statistical parametric mapping (SPM8), was used to correlate changes of the Bayley III scores with the regional distribution of MD, FA, λ// and λ[perpendicular]. We found that language abilities are negatively correlated to MD, λ// and λ[perpendicular] in the left superior temporal gyrus in preterm infants. These findings suggest that higher MD, λ// and λ[perpendicular] values at term-equivalent age in the left superior temporal gyrus are associated with poorer language scores in later childhood. Consequently, it highlights the key role of the left superior temporal gyrus for the development of language abilities in children. Further studies are needed to assess on an individual basis and on the long term the prognostic value of brain DTI at term equivalent age for the development of language. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. PET/MR Imaging in Gynecologic Oncology.

    Science.gov (United States)

    Ohliger, Michael A; Hope, Thomas A; Chapman, Jocelyn S; Chen, Lee-May; Behr, Spencer C; Poder, Liina

    2017-08-01

    MR imaging and PET using 2-Deoxy-2-[ 18 F]fluoroglucose (FDG) are both useful in the evaluation of gynecologic malignancies. MR imaging is superior for local staging of disease whereas fludeoxyglucose FDG PET is superior for detecting distant metastases. Integrated PET/MR imaging scanners have great promise for gynecologic malignancies by combining the advantages of each modality into a single scan. This article reviews the technology behind PET/MR imaging acquisitions and technical challenges relevant to imaging the pelvis. A dedicated PET/MR imaging protocol; the roles of PET and MR imaging in cervical, endometrial, and ovarian cancers; and future directions for PET/MR imaging are discussed. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Revising superior planning performance in chess players: the impact of time restriction and motivation aspects.

    Science.gov (United States)

    Unterrainer, Josef Martin; Kaller, Christoph Philipp; Leonhart, Rainer; Rahm, Benjamin

    2011-01-01

    In a previous study (Unterrainer, Kaller, Halsband, & Rahm, 2006), chess players outperformed non-chess players in the Tower of London planning task but exhibited disproportionately longer processing times. This pattern of results raises the question of whether chess players' planning capabilities are superior or whether the results reflect differences in the speed-accuracy trade-off between the groups, possibly attributable to sports motivation. The present study was designed to disambiguate these alternative suggestions by implementing various constraints on planning time and by assessing self-reported motivation. In contrast to the previous study, chess players' performance was not superior, independently of whether problems had to be solved with (Experiment 1) or without (Experiment 2) time limits. As expected, chess players reported higher overall trait and state motivation scores across both experiments. These findings revise the notion of superior planning performance in chess players. In consequence, they do not conform with the assumption of a general transfer of chess-related planning expertise to other cognitive domains, instead suggesting that superior performance may be possible only under specific circumstances such as receiving competitive instructions.

  19. Effective configurations of value creation and capture capabilities : extending Treacy and Wiersema’s value disciplines

    NARCIS (Netherlands)

    Zacharias, N.; Nijssen, E.J.; Stock, R.M.

    2016-01-01

    This article theoretically elaborates and empirically investigates the alignment of the value creation and capture capabilities of Treacy and Wiersema’s (1993, 1995) typology of three strategies for superior customer value (product leadership, operational excellence, and customer intimacy). Drawing

  20. Cerebral and meningeal manifestations of AIDS: comparison of plain T2-weighted images and Gd-DTPA enhanced T1-weighted images in 105 patients

    International Nuclear Information System (INIS)

    Jochens, R.; Henkes, H.; Steinkamp, H.J.; Terstegge, K.; Hosten, N.; Ruf, B.; Schoerner, W.

    1994-01-01

    The purpose of the present study was to evaluate the potential of T1-weighted Gd-DTPA enhanced MR imaging in the diagnosis of cerebral manifestations of AIDS. 105 patients with AIDS were imaged with plain T2-weighted images as well as with Gd-DTPA enhanced T1-weighted pulse sequences. Our study revealed comparable sensitivities in the detection of morphological changes as shown on plain T2-weighted images and Gd-DTPA enhanced T1-weighted images in 55% of patients (normal and pathologic findings). Plain T2-weighted images were superior in 28.5% and provided significantly better results in 8.5% of patients. Gd-DTPA enhanced T1-weighted images were superior in only 5% cases and revealed significantly better results in 3%. As a result, T2-weighted plain images were superior in approximately 40% of patients concerning detection of morphologic changes. In almost 10% of patients with parechymal and meningeal lesions, Gd-DTPA enhanced T1-weighted images, however, were superior or even significantly better compared to T2-weighted plain images. The detection of morphologic changes in MR imaging can be further increased with Gd-DTPA. With regard to differential diagnosis and diesease activity, plain T2-weighted images and Gd-DTPA enhanced T1-weighted images revealed comparable results in 42% of patients (normal and pathologic findings). T2-weighted plain images were superior in 2% of cases whereas Gd-DTPA enhanced T1-weighted images were superior in as much as 56% of patient. MR imaging enhanced with Gd-DTPA yielded additional information on disease activity in 73% of patients with pathologic findings in the cerebral parechyma and the meninges. The surplus of information also refers to the etiology of cerebral pathology and differential diagnosis. Because of the frequency of cerebral manifestations in AIDS, early diagnosis for initiation of therapy and follow-up studies to monitor therapy are crucial. (orig./MG) [de

  1. The MDCT and MRI Findings of a Pancreatic Arteriovenous Malformation Combined with Isolated Dissection of the Superior Mesenteric Artery: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Soo; Jeong, Woo Kyoung [Hanyang University Guri Hospital, Seoul (Korea, Republic of); Kim, Jin Oo [Naval Pohang Hospital, Pohang (Korea, Republic of); Oh, Ji Young; Song, Soon Young [Hanyang University Medical College, Seoul (Korea, Republic of)

    2010-03-15

    Pancreatic arteriovenous malformation and isolated spontaneous dissection of the superior mesenteric artery are both rare maladies, and now they can be easily diagnosed due to the development of such noninvasive modalities as multi-detector computed tomography and magnetic resonance imaging. We report here on the multi-detector computed tomography and magnetic resonance imaging findings of a rare case of pancreatic arteriovenous malformation combined with isolated dissection of the superior mesenteric artery.

  2. The MDCT and MRI Findings of a Pancreatic Arteriovenous Malformation Combined with Isolated Dissection of the Superior Mesenteric Artery: A Case Report

    International Nuclear Information System (INIS)

    Kim, Yong Soo; Jeong, Woo Kyoung; Kim, Jin Oo; Oh, Ji Young; Song, Soon Young

    2010-01-01

    Pancreatic arteriovenous malformation and isolated spontaneous dissection of the superior mesenteric artery are both rare maladies, and now they can be easily diagnosed due to the development of such noninvasive modalities as multi-detector computed tomography and magnetic resonance imaging. We report here on the multi-detector computed tomography and magnetic resonance imaging findings of a rare case of pancreatic arteriovenous malformation combined with isolated dissection of the superior mesenteric artery

  3. Superior vesical fissure concealed by giant omphalocele: A case report

    OpenAIRE

    Hayek, Danial; Massanyi, Eric; Mancuso, Melissa; Krepkovich, Katherine; Garrison, Aaron

    2016-01-01

    Omphalocele is an abdominal wall defect characterized by exteriorization of abdominal viscera that is covered by a membrane. Omphalocele has a well-known association with chromosome abnormalities. Here we present a case of a superior vesical fissure (SVF) initially disguised as a giant omphalocele in a newborn with trisomy 18. We also show unique prenatal imaging and discuss the importance and limitations of prenatal genetic testing.

  4. Synthetic aperture radar capabilities in development

    Energy Technology Data Exchange (ETDEWEB)

    Miller, M. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    The Imaging and Detection Program (IDP) within the Laser Program is currently developing an X-band Synthetic Aperture Radar (SAR) to support the Joint US/UK Radar Ocean Imaging Program. The radar system will be mounted in the program`s Airborne Experimental Test-Bed (AETB), where the initial mission is to image ocean surfaces and better understand the physics of low grazing angle backscatter. The Synthetic Aperture Radar presentation will discuss its overall functionality and a brief discussion on the AETB`s capabilities. Vital subsystems including radar, computer, navigation, antenna stabilization, and SAR focusing algorithms will be examined in more detail.

  5. MR imaging of congenital heart diseases in adolescents and adults

    International Nuclear Information System (INIS)

    Choe, Yeon Hyeon; Kang, I Seok; Park, Seung Woo; Lee, Heung Jae

    2001-01-01

    Echocardiography and catheterization angiography suffer certain limitations in the evaluation of congenital heart diseases in adults, though these are overcome by MRI, in which a wide field-of view, unlimited multiplanar imaging capability and three-dimensional contrast-enhanced MR angiography techniques are used. In adults, recently introduced fast imaging techniques provide cardiac MR images of sufficient quality and with less artifacts. Ventricular volume, ejection fraction, and vascular flow measurements, including pressure gradients and pulmonary-to-systemic flow ratio, can be calculated or obtained using fast cine MRI, phase-contrast MR flow-velocity mapping, and semiautomatic analysis software. MRI is superior to echocardiography in diagnosing partial anomalous pulmonary venous connection, unroofed coronary sinus, anomalies of the pulmonary arteries, aorta and systemic veins, complex heart diseases, and postsurgical sequelae. Biventricular function is reliably evaluated with cine MRI after repair of tetralogy of Fallot, and Senning's and Mustard's operations. MRI has an important and growing role in the morphologic and functional assessment of congenital heart diseases in adolescents and adults

  6. Reproduction of superior sagittal sinus animal model by bypass transplantation of biomaterial graft

    Directory of Open Access Journals (Sweden)

    Qing-yong LUO

    2011-03-01

    Full Text Available Objective To establish the beagles model of superior sagittal sinus bypass graft,and explore the feasibility of reconstruction of superior sagittal sinus with biomaterials using this model.Methods Eight adult male beagles(weight: 12.5-22.0kg were involved in the present study.The superior sagittal sinus was exposed and blocked via bone window,and then anastomosed side-to-end to the biomaterial graft under the dedicated microscope of neurosurgery surgery,expectant treatment such as anti-inflammatory was given for the animals.The digital subtraction venography(DSV and color Doppler flow imaging(CDFI of superior sagittal sinus were performed in 1,2,4 and 8 weeks after the operation.Eight weeks after the operation,all the animals were sacrificed and the material graft was examined histologically.Results The DSV and CDFI of superior sagittal sinus showed that the stomas of 2 beagles were with slight stenosis and high flow velocity,of 1 beagle with small leakage and low flow velocity,while of other 5 beagles were normal.The histological examination showed endothelial cells were growing on the graft and superior sagittal sinus,and crawling toward the lumen of graft 8 weeks after the operation.Conclusion The beagles model of superior sagittal sinus bypass graft was established successfully.The short-term effect of the model was satisfactory,while further work should be performed to determine the long-term effects.

  7. Randomized trial for superiority of high field strength intra-operative magnetic resonance imaging guided resection in pituitary surgery.

    Science.gov (United States)

    Tandon, Vivek; Raheja, Amol; Suri, Ashish; Chandra, P Sarat; Kale, Shashank S; Kumar, Rajinder; Garg, Ajay; Kalaivani, Mani; Pandey, Ravindra M; Sharma, Bhawani S

    2017-03-01

    Till date there are no randomized trials to suggest the superiority of intra-operative magnetic resonance imaging (IOMRI) guided trans-sphenoidal pituitary resection over two dimensional fluoroscopic (2D-F) guided resections. We conducted this trial to establish the superiority of IOMRI in pituitary surgery. Primary objective was to compare extent of tumor resection between the two study arms. It was a prospective, randomized, outcome assessor and statistician blinded, two arm (A: IOMRI, n=25 and B: 2D-F, n=25), parallel group clinical trial. 4 patients from IOMRI group cross-over to 2D-F group and were consequently analyzed in latter group, based on modified intent to treat method. A total of 50 patients were enrolled till completion of trial (n=25 in each study arm). Demographic profile and baseline parameters were comparable among the two arms (p>0.05) except for higher number of endoscopic procedures and experienced neurosurgeons (>10years) in arm B (p=0.02, 0.002 respectively). Extent of resection was similar in both study arms (A, 94.9% vs B, 93.6%; p=0.78), despite adjusting for experience of operating surgeon and use of microscope/endoscope for surgical resection. We observed that use of IOMRI helped optimize the extent of resection in 5/20 patients (25%) for pituitary tumor resection in-group A. Present study failed to observe superiorty of IOMRI over conventional 2D-F guided resection in pituitary macroadenoma surgery. By use of this technology, younger surgeons could validate their results intra-operatively and hence could increase EOR without causing any increase in complications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Adaptive tight frame based medical image reconstruction: a proof-of-concept study for computed tomography

    International Nuclear Information System (INIS)

    Zhou, Weifeng; Cai, Jian-Feng; Gao, Hao

    2013-01-01

    A popular approach for medical image reconstruction has been through the sparsity regularization, assuming the targeted image can be well approximated by sparse coefficients under some properly designed system. The wavelet tight frame is such a widely used system due to its capability for sparsely approximating piecewise-smooth functions, such as medical images. However, using a fixed system may not always be optimal for reconstructing a variety of diversified images. Recently, the method based on the adaptive over-complete dictionary that is specific to structures of the targeted images has demonstrated its superiority for image processing. This work is to develop the adaptive wavelet tight frame method image reconstruction. The proposed scheme first constructs the adaptive wavelet tight frame that is task specific, and then reconstructs the image of interest by solving an l 1 -regularized minimization problem using the constructed adaptive tight frame system. The proof-of-concept study is performed for computed tomography (CT), and the simulation results suggest that the adaptive tight frame method improves the reconstructed CT image quality from the traditional tight frame method. (paper)

  9. Comparison of quality of ultrasonographic image of the pancreas: Tissue harmonic image vs. Fundamental image

    International Nuclear Information System (INIS)

    Seo, Young Lan; Choi, Chul Soon; Kim, Ho Chul; Yoon, Dae Young; Han, Dae Hee; Bae, Sang Hoon

    2002-01-01

    To compare the quality of ultrasonographic (US) images, tissue harmonic image (THI) versus fundamental image (FI), of the pancreas. During a recent 2 month period, forty one patients with the normal pancreas on US were included. All of them were free of abnormal clinical and laboratory findings suggestive of pancreatic disease, US was performed by an abdominal radiologist with a 2.5-5 MHz convex-array transducer (Sequoia 512: Acuson, Mountain View, Calif.U.S.A.). Comparison of THI and FI of the pancreas was done for the following parameters:conspicuity, intermal architecture, and delineation range. Grading was made by the consensus of two abdominal radiologist witha three-point scale. Statistical analysis was done using Wilcox signed rank sum test. For the evaluation of the US image quality of the pancreas THI showed better conspicuity (p=0.0130), clearer internal architecture (p=0.0029) and superior delineation range (p=0.0191) than those of FI. THI appears to show a superior image quality than FI in evaluation of the pancreas.

  10. Posterior semicircular canal dehiscence: a morphologic cause of vertigo similar to superior semicircular canal dehiscence

    International Nuclear Information System (INIS)

    Krombach, G.A.; Schmitz-Rode, T.; Haage, P.; Guenther, R.W.; DiMartino, E.; Prescher, A.; Kinzel, S.

    2003-01-01

    Heading Abstract.The aim of this study was to assess imaging findings of posterior semicircular dehiscence on computed tomography and to evaluate incidence of posterior and superior semicircular canal dehiscence in patients presenting with vertigo, sensorineuronal hearing loss or in a control group without symptoms related to the inner ear. Computed tomography was performed in 507 patients presenting either with vertigo (n=128; 23 of these patients suffered also from sensorineuronal hearing loss), other symptoms related to the inner ear, such as hearing loss or tinnitus (n=183) or symptoms unrelated to the labyrinth (n=196). All images were reviewed for presence of dehiscence of the bone, overlying the semicircular canals. Twenty-nine patients had superior semicircular canal dehiscence. Of these patients, 83% presented with vertigo, 10% with hearing loss or tinnitus and the remaining 7% with symptoms unrelated to the inner ear. In 23 patients dehiscence of the posterior semicircular canal was encountered. Of these patients, 86% presented with vertigo, 9% with hearing loss or tinnitus and 5% with symptoms unrelated to the inner ear. Defects of the bony overly are found at the posterior semicircular canal, in addition to the recently introduced superior canal dehiscence syndrome. Significant prevalence of vertigo in these patients suggests that posterior semicircular canal dehiscence can cause vertigo, similar to superior semicircular canal dehiscence. (orig.)

  11. Posterior semicircular canal dehiscence: a morphologic cause of vertigo similar to superior semicircular canal dehiscence

    Energy Technology Data Exchange (ETDEWEB)

    Krombach, G A; Schmitz-Rode, T; Haage, P; Guenther, R W [Department of Diagnostic Radiology, University of Technology, Pauwelstrasse 30, 52057, Aachen (Germany); DiMartino, E [Department of Otorhinolaryngology, University of Technology, Pauwelstrasse 30, 52057, Aachen (Germany); Prescher, A [Department of Anatomy, University of Technology, Pauwelstrasse 30, 52057, Aachen (Germany); Kinzel, S [Department of Experimental Veterinarian Medicine, University of Technology, Pauwelstrasse 30, 52057, Aachen (Germany)

    2003-06-01

    Heading Abstract.The aim of this study was to assess imaging findings of posterior semicircular dehiscence on computed tomography and to evaluate incidence of posterior and superior semicircular canal dehiscence in patients presenting with vertigo, sensorineuronal hearing loss or in a control group without symptoms related to the inner ear. Computed tomography was performed in 507 patients presenting either with vertigo (n=128; 23 of these patients suffered also from sensorineuronal hearing loss), other symptoms related to the inner ear, such as hearing loss or tinnitus (n=183) or symptoms unrelated to the labyrinth (n=196). All images were reviewed for presence of dehiscence of the bone, overlying the semicircular canals. Twenty-nine patients had superior semicircular canal dehiscence. Of these patients, 83% presented with vertigo, 10% with hearing loss or tinnitus and the remaining 7% with symptoms unrelated to the inner ear. In 23 patients dehiscence of the posterior semicircular canal was encountered. Of these patients, 86% presented with vertigo, 9% with hearing loss or tinnitus and 5% with symptoms unrelated to the inner ear. Defects of the bony overly are found at the posterior semicircular canal, in addition to the recently introduced superior canal dehiscence syndrome. Significant prevalence of vertigo in these patients suggests that posterior semicircular canal dehiscence can cause vertigo, similar to superior semicircular canal dehiscence. (orig.)

  12. Information Superiority generated through proper application of Geoinformatics

    Science.gov (United States)

    Teichmann, F.

    2012-04-01

    Information Superiority generated through proper application of Geoinformatics Information management and especially geoscience information delivery is a very delicate task. If it is carried out successfully, geoscientific data will provide the main foundation of Information Superiority. However, improper implementation of geodata generation, assimilation, distribution or storage will not only waste valuable resources like manpower or money, but could also give rise to crucial deficiency in knowledge and might lead to potentially extremely harmful disasters or wrong decisions. Comprehensive Approach, Effect Based Operations and Network Enabled Capabilities are the current buzz terms in the security regime. However, they also apply to various interdisciplinary tasks like catastrophe relief missions, civil task operations or even in day to day business operations where geo-science data is used. Based on experience in the application of geoscience data for defence applications the following procedure or tool box for generating geodata should lead to the desired information superiority: 1. Understand and analyse the mission, the task and the environment for which the geodata is needed 2. Carry out a Information Exchange Requirement between the user or customer and the geodata provider 3. Implementation of current interoperability standards and a coherent metadata structure 4. Execute innovative data generation, data provision, data assimilation and data storage 5. Apply a cost-effective and reasonable data life cycle 6. Implement IT security by focusing of the three pillar concepts Integrity, Availability and Confidentiality of the critical data 7. Draft and execute a service level agreement or a memorandum of understanding between the involved parties 8. Execute a Continuous Improvement Cycle These ideas from the IT world should be transferred into the geoscience community and applied in a wide set of scenarios. A standardized approach of how to generate, provide

  13. Preliminary assessment of the imaging capability of the YAP-(S)PET small animal scanner in neuroscience

    International Nuclear Information System (INIS)

    Bartoli, Antonietta; Belcari, Nicola; Stark, Daniela; Hoehnemann, Sabine; Piel, Markus; Jennewein, Marc; Schmitt, Ulrich; Tillmanns, Julia; Thews, Oliver; Hiemke, Christoph; Roesch, Frank; Del Guerra, Alberto

    2006-01-01

    The new and fully engineered version of the YAP-(S)PET small animal scanner has been tested at the University of Mainz for preliminary assessment of its imaging capability for studies related to neuropharmacology and psychiatry. The main feature of the scanner is the capability to combine PET and SPECT techniques. It allows the development of new and interesting protocols for the investigation of many biological phenomena, more effectively than with PET or SPECT modalities alone. The scanner is made up of four detector heads, each one composed of a 4x4 cm 2 of YAlO 3 :Ce (or YAP:Ce) matrix, and has a field of view (FOV) of 4 cm axiallyx4 cm o transaxially. In PET mode, the volume resolution is less than 8 mm 3 and is nearly constant over the whole FOV, while the sensitivity is about 2%. The SPECT performance is not so good, due to the presence of the multi-hole lead collimator in front of each head. Nevertheless, the YAP-PET scanner offers excellent resolution and sensitivity for performing on the availability of D2-like dopamine receptors on mice and rats in both PET and SPECT modalities

  14. Superior vesical fissure concealed by giant omphalocele: A case report

    Directory of Open Access Journals (Sweden)

    Danial Hayek

    2016-11-01

    Full Text Available Omphalocele is an abdominal wall defect characterized by exteriorization of abdominal viscera that is covered by a membrane. Omphalocele has a well-known association with chromosome abnormalities. Here we present a case of a superior vesical fissure (SVF initially disguised as a giant omphalocele in a newborn with trisomy 18. We also show unique prenatal imaging and discuss the importance and limitations of prenatal genetic testing.

  15. Superior ophthalmic vein enlargement and increased muscle index in dysthyroid optic neuropathy.

    Science.gov (United States)

    Lima, Breno da Rocha; Perry, Julian D

    2013-01-01

    To compare superior ophthalmic vein diameter and extraocular muscle index in patients with thyroid eye disease with or without optic neuropathy. High-resolution CT scan images of 40 orbits of 20 patients with history of thyroid eye disease (with or without optic neuropathy), who underwent orbital decompression surgery from January 2007 to November 2009, were retrospectively reviewed. Superior ophthalmic vein diameter was measured in coronal and axial planes. Extraocular muscle index was calculated according to the method proposed by Barrett et al. The clinical diagnosis of optic neuropathy was based on characteristic signs that included afferent pupillary defect, decreased visual acuity, visual field defects, and dyschromatopsia. Orbits were divided in 2 groups based on presence or absence of optic neuropathy. Superior ophthalmic vein diameter was significantly higher in orbits with concomitant optic neuropathy (mean 2.4 ± 0.4mm, p optic neuropathy (mean 57.9% ± 5.7%, p = 0.0002). Muscle index greater than 50% was present in all patients with dysthyroid optic neuropathy. This study suggests that patients with thyroid eye disease with enlarged superior ophthalmic vein and increased extraocular muscle index are more likely to have concomitant optic neuropathy.

  16. Radiation-induced leiomyosarcoma of the great vessels presenting as superior vena cava syndrome

    International Nuclear Information System (INIS)

    Weiss, K.S.; Zidar, B.L.; Wang, S.

    1987-01-01

    A patient with a pleomorphic intravascular leiomyosarcoma of the great vessels of the neck and mediastinum presented clinically with a superior vena cava syndrome. A latent period of 29 years elapsed between receiving orthovoltage radiation to the neck and right side of chest to treat recurrent ganglioneuroblastoma, and the appearance of a leiomyosarcoma and subsequent recurrences. The patient underwent partial resection of the tumor, received adjunct chemotherapy, and was shown to be free of disease by clinical tests and by magnetic resonance imaging (MRI) 17 months after completion of chemotherapy. The criteria for the diagnosis of radiation-induced sarcomas are reviewed in relation to the present case. The critical role of magnetic resonance imaging in both the diagnosis and continued follow-up of the patient is described. This would appear to be the first reported case of radiation-induced intravascular leiomyosarcoma of the great vessels of the neck and mediastinum presenting as a superior vena cava syndrome

  17. MR imaging of von Hippel-Lindau disease

    International Nuclear Information System (INIS)

    Sato, Y.; Waziri, M.H.; Smith, W.L.; Frey, E.E.; Franken, E.A.

    1986-01-01

    Sixteen patients with von Hippel-Lindau disease (VH-L) and 11 asymptomatic family members underwent a total of 29 central nervous system (CNS) and 23 body MR imaging evaluations during a 2-year study period. Nineteen CNS and spinal lesions and nine abdominal visceral lesions were identified on MR imaging and were confirmed at surgery or by other imaging modalities. MR imaging is superior to CT in the evaluation of intraocular vitreous abnormalities and cerebellar and spinal hemangioblastomas because of superior tissue characterization and lack of bone artifacts. MR imaging adequately demonstrated the abdominal visceral lesions. MR imaging is a sensitive and reliable imaging modality for the various lesions of VH-L

  18. Prevalence of 'high-riding' superior pericardial recesses on thin-section 16-MDCT scans

    Energy Technology Data Exchange (ETDEWEB)

    Basile, Antonio [Department of Radiology and Interventional Radiology, Ospedale Ferrarotto, via Citelli, 8 95124 Catania (Italy)]. E-mail: antodoc@yahoo.com; Bisceglie, Paola [Department of Radiology and Interventional Radiology, Ospedale Ferrarotto, via Citelli, 8 95124 Catania (Italy); Giulietti, Giorgio [Department of Radiology and Interventional Radiology, Ospedale Ferrarotto, via Citelli, 8 95124 Catania (Italy); Calcara, Giacomo [Department of Radiology and Interventional Radiology, Ospedale Ferrarotto, via Citelli, 8 95124 Catania (Italy); Figuera, Michele [Department of Radiology, Ospedale Vittorio Emanuele, Via Plebiscito 628, 95124 Catania (Italy); Mundo, Elena [Department of Radiology and Interventional Radiology, Ospedale Ferrarotto, via Citelli, 8 95124 Catania (Italy); Granata, Antonio [Department of Nephrology, Ospedale Vittorio Emanuele, Via Plebiscito 628, 95124 Catania (Italy); Runza, Giuseppe [Department of Radiology, Policlinico Universitario, Via del Vespro 129, 90127 Palermo (Italy); Privitera, Carmelo [Department of Radiology, Ospedale Vittorio Emanuele, Via Plebiscito 628, 95124 Catania (Italy); Privitera, Giambattista [Department of Radiology and Interventional Radiology, Ospedale Ferrarotto, via Citelli, 8 95124 Catania (Italy); Patti, Maria Teresa [Department of Radiology and Interventional Radiology, Ospedale Ferrarotto, via Citelli, 8 95124 Catania (Italy)

    2006-08-15

    Objective: The aim of this study was to evaluate the prevalence of 'high-riding' superior pericardial recess (HRSPR) on thin-section (1 mm) 16-multidetector computed tomography (MDCT) scans. Materials and methods: Three hundred and fourteen consecutive chest CT scans obtained with a thin-section 16 MDCT were retrospectively evaluated. The prevalence and characteristic of HRSPR were analyzed. Results: HRSPR was depicted in 21 patients (11 men and 10 women) (6.6%) who ranged in age from 28 to 72 years (mean age, 57 years). The extended recesses were rounded/oval shaped in five patients and triangular, spindle, half moon or irregular shaped in the other 16 patients. Conclusion: Our data suggest as HRSPRs are more frequently and better depicted on thinsection MDCT scans, and this improves the capability to distinguish this superior extension of the superior aortic recess from abnormal findings such as lymphadenopathy, cystic lesions, and aortic dissection.

  19. Anatomical relation between S1 sacroiliac screws' entrance points and superior gluteal artery.

    Science.gov (United States)

    Zhao, Yong; You, Libo; Lian, Wei; Zou, Dexin; Dong, Shengjie; Sun, Tao; Zhang, Shudong; Wang, Dan; Li, Jingning; Li, Wenliang; Zhao, Yuchi

    2018-01-18

    To conduct radiologic anatomical study on the relation between S1 sacroiliac screws' entry points and the route of the pelvic outer superior gluteal artery branches with the aim to provide the anatomical basis and technical reference for the avoidance of damage to the superior gluteal artery during the horizontal sacroiliac screw placement. Superior gluteal artery CTA (CT angiography) vascular imaging of 74 healthy adults (37 women and 37 men) was done with 128-slice spiral CT (computed tomography). The CT attendant-measuring software was used to portray the "safe bony entrance area" (hereinafter referred to as "Safe Area") of the S1 segment in the standard lateral pelvic view of three-dimensional reconstruction. The anatomical relation between S1 sacroiliac screws' Safe Area and the pelvic outer superior gluteal artery branches was observed and recorded. The number of cases in which artery branches intersected the Safe Area was counted. The cases in which superior gluteal artery branches disjointed from the Safe Area were identified, and the shortest distance between the Safe Area and the superior gluteal artery branch closest to the Safe Area was measured. Three cases out of the 74 sample cases were excluded from this study as they were found to have no bony space for horizontal screw placement in S1 segment. Among the remaining 71 sample cases, there are 32 cases (45.1%) where the deep superior branch of superior gluteal artery passes through the Safe Area of S1 entrance point. There was no distinguishing feature and rule on how the deep superior branches and the Safe Area overlapped. In the 39 cases in which superior gluteal artery branches disjointed from the Safe Area, the deep superior branches of superior gluteal artery were the branches closest to the Safe Area and the part of the branch closest to the Safe Area was located in front of the widest part of the Safe Area. The shortest distance between the deep superior branch and the Safe Area is 0.86

  20. CT and MR imaging of craniopharyngioma

    Energy Technology Data Exchange (ETDEWEB)

    Tsuda, M. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Takahashi, S. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Higano, S. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Kurihara, N. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Ikeda, H. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Neurosurgery; Sakamoto, K. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology

    1997-05-01

    We reviewed imaging findings of CT and MR imaging in 20 cases of surgically confirmed craniopharyngioma in an attempt to determine their relation to patterns of tumor extent. The relationship between these patterns and the frequency of preoperative CT diagnosis and MR imaging diagnosis according to the surgical diagnosis were determined. The CT technique was superior to MR imaging in the detection of calcification. The MR imaging technique was superior to CT for determining tumor extent and provided valuable information about the relationships of the tumor to surrounding structures. Thus, CT and MR imaging have complementary roles in the diagnosis of craniopharyngiomas. In cases of possible craniopharyngioma, noncontrast sagittal T1-weighted images may enable the identification of the normal pituitary, possibly leading to the correct diagnosis. (orig.)

  1. CT and MR imaging of craniopharyngioma

    International Nuclear Information System (INIS)

    Tsuda, M.; Takahashi, S.; Higano, S.; Kurihara, N.; Ikeda, H.; Sakamoto, K.

    1997-01-01

    We reviewed imaging findings of CT and MR imaging in 20 cases of surgically confirmed craniopharyngioma in an attempt to determine their relation to patterns of tumor extent. The relationship between these patterns and the frequency of preoperative CT diagnosis and MR imaging diagnosis according to the surgical diagnosis were determined. The CT technique was superior to MR imaging in the detection of calcification. The MR imaging technique was superior to CT for determining tumor extent and provided valuable information about the relationships of the tumor to surrounding structures. Thus, CT and MR imaging have complementary roles in the diagnosis of craniopharyngiomas. In cases of possible craniopharyngioma, noncontrast sagittal T1-weighted images may enable the identification of the normal pituitary, possibly leading to the correct diagnosis. (orig.)

  2. Phantom evaluation of a commercially available three modality image guided radiation therapy system

    International Nuclear Information System (INIS)

    Ploquin, Nicolas; Rangel, Alejandra; Dunscombe, Peter

    2008-01-01

    The authors describe a detailed evaluation of the capabilities of imaging and image registration systems available with Varian linear accelerators for image guided radiation therapy (IGRT). Specifically, they present modulation transfer function curves for megavoltage planar, kilovoltage (kV) planar, and cone beam computed tomography imaging systems and compare these with conventional computed tomography. While kV planar imaging displayed the highest spatial resolution, all IGRT imaging techniques were assessed as adequate for their intended purpose. They have also characterized the image registration software available for use in conjunction with these imaging systems through a comprehensive phantom study involving translations in three orthogonal directions. All combinations of imaging systems and image registration software were found to be accurate, although the planar kV imaging system with automatic registration was generally superior, with both accuracy and precision of the order of 1 mm, under the conditions tested. Based on their phantom study, the attainable accuracy for rigid body translations using any of the features available with Varian equipment will more likely be limited by the resolution of the couch readouts than by inherent limitations in the imaging systems and image registration software. Overall, the accuracy and precision of currently available IGRT technology exceed published experience with the accuracy and precision of contouring for planning.

  3. Possible origin of superior corrosion resistance for electrodeposited nanocrystalline Ni

    International Nuclear Information System (INIS)

    Roy, I.; Yang, H.W.; Dinh, L.; Lund, I.; Earthman, J.C.; Mohamed, F.A.

    2008-01-01

    We present here for the first time observations that grain boundaries in electrodeposited (ED) nanocrystalline (nc) Ni are predominantly of Σ3 character. The results presented are based on orientation imaging microscopy (OIM) performed to produce electron backscatter diffraction (EBSD) maps. This large volume fraction of coherent low sigma coincidence site lattice (CSL) boundaries appears to be consistent with the superior corrosion resistance of ED nc-Ni in comparison with its coarse-grained counterpart

  4. Crystal analyser-based X-ray phase contrast imaging in the dark field: implementation and evaluation using excised tissue specimens

    International Nuclear Information System (INIS)

    Ando, Masami; Sunaguchi, Naoki; Wu, Yanlin; Do, Synho; Sung, Yongjin; Gupta, Rajiv; Louissaint, Abner; Yuasa, Tetsuya; Ichihara, Shu

    2014-01-01

    We demonstrate the soft tissue discrimination capability of X-ray dark-field imaging (XDFI) using a variety of human tissue specimens. The experimental setup for XDFI comprises an X-ray source, an asymmetrically cut Bragg-type monochromator-collimator (MC), a Laue-case angle analyser (LAA) and a CCD camera. The specimen is placed between the MC and the LAA. For the light source, we used the beamline BL14C on a 2.5-GeV storage ring in the KEK Photon Factory, Tsukuba, Japan. In the eye specimen, phase contrast images from XDFI were able to discriminate soft-tissue structures, such as the iris, separated by aqueous humour on both sides, which have nearly equal absorption. Superiority of XDFI in imaging soft tissue was further demonstrated with a diseased iliac artery containing atherosclerotic plaque and breast samples with benign and malignant tumours. XDFI on breast tumours discriminated between the normal and diseased terminal duct lobular unit and between invasive and in-situ cancer. X-ray phase, as detected by XDFI, has superior contrast over absorption for soft tissue processes such as atherosclerotic plaque and breast cancer. (orig.)

  5. Crystal analyser-based X-ray phase contrast imaging in the dark field: implementation and evaluation using excised tissue specimens

    Energy Technology Data Exchange (ETDEWEB)

    Ando, Masami [RIST, Tokyo University of Science, Noda, Chiba (Japan); Sunaguchi, Naoki [Gunma University, Graduate School of Engineering, Kiryu, Gunma (Japan); Wu, Yanlin [The Graduate University for Advanced Studies, Department of Materials Structure Science, School of High Energy Accelerator Science, Tsukuba, Ibaraki (Japan); Do, Synho; Sung, Yongjin; Gupta, Rajiv [Massachusetts General Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States); Louissaint, Abner [Massachusetts General Hospital and Harvard Medical School, Department of Pathology, Boston, MA (United States); Yuasa, Tetsuya [Yamagata University, Faculty of Engineering, Yonezawa, Yamagata (Japan); Ichihara, Shu [Nagoya Medical Center, Department of Pathology, Nagoya, Aichi (Japan)

    2014-02-15

    We demonstrate the soft tissue discrimination capability of X-ray dark-field imaging (XDFI) using a variety of human tissue specimens. The experimental setup for XDFI comprises an X-ray source, an asymmetrically cut Bragg-type monochromator-collimator (MC), a Laue-case angle analyser (LAA) and a CCD camera. The specimen is placed between the MC and the LAA. For the light source, we used the beamline BL14C on a 2.5-GeV storage ring in the KEK Photon Factory, Tsukuba, Japan. In the eye specimen, phase contrast images from XDFI were able to discriminate soft-tissue structures, such as the iris, separated by aqueous humour on both sides, which have nearly equal absorption. Superiority of XDFI in imaging soft tissue was further demonstrated with a diseased iliac artery containing atherosclerotic plaque and breast samples with benign and malignant tumours. XDFI on breast tumours discriminated between the normal and diseased terminal duct lobular unit and between invasive and in-situ cancer. X-ray phase, as detected by XDFI, has superior contrast over absorption for soft tissue processes such as atherosclerotic plaque and breast cancer. (orig.)

  6. CloudSat-Based Assessment of GPM Microwave Imager Snowfall Observation Capabilities

    Directory of Open Access Journals (Sweden)

    Giulia Panegrossi

    2017-12-01

    Full Text Available The sensitivity of Global Precipitation Measurement (GPM Microwave Imager (GMI high-frequency channels to snowfall at higher latitudes (around 60°N/S is investigated using coincident CloudSat observations. The 166 GHz channel is highlighted throughout the study due to its ice scattering sensitivity and polarization information. The analysis of three case studies evidences the important combined role of total precipitable water (TPW, supercooled cloud water, and background surface composition on the brightness temperature (TB behavior for different snow-producing clouds. A regression tree statistical analysis applied to the entire GMI-CloudSat snowfall dataset indicates which variables influence the 166 GHz polarization difference (166 ∆TB and its relation to snowfall. Critical thresholds of various parameters (sea ice concentration (SIC, TPW, ice water path (IWP are established for optimal snowfall detection capabilities. The 166 ∆TB can identify snowfall events over land and sea when critical thresholds are exceeded (TPW > 3.6 kg·m−2, IWP > 0.24 kg·m−2 over land, and SIC > 57%, TPW > 5.1 kg·m−2 over sea. The complex combined 166 ∆TB-TB relationship at higher latitudes and the impact of supercooled water vertical distribution are also investigated. The findings presented in this study can be exploited to improve passive microwave snowfall detection algorithms.

  7. All-sky-imaging capabilities for ionospheric space weather research using geomagnetic conjugate point observing sites

    Science.gov (United States)

    Martinis, C.; Baumgardner, J.; Wroten, J.; Mendillo, M.

    2018-04-01

    Optical signatures of ionospheric disturbances exist at all latitudes on Earth-the most well known case being visible aurora at high latitudes. Sub-visual emissions occur equatorward of the auroral zones that also indicate periods and locations of severe Space Weather effects. These fall into three magnetic latitude domains in each hemisphere: (1) sub-auroral latitudes ∼40-60°, (2) mid-latitudes (20-40°) and (3) equatorial-to-low latitudes (0-20°). Boston University has established a network of all-sky-imagers (ASIs) with sites at opposite ends of the same geomagnetic field lines in each hemisphere-called geomagnetic conjugate points. Our ASIs are autonomous instruments that operate in mini-observatories situated at four conjugate pairs in North and South America, plus one pair linking Europe and South Africa. In this paper, we describe instrument design, data-taking protocols, data transfer and archiving issues, image processing, science objectives and early results for each latitude domain. This unique capability addresses how a single source of disturbance is transformed into similar or different effects based on the unique "receptor" conditions (seasonal effects) found in each hemisphere. Applying optical conjugate point observations to Space Weather problems offers a new diagnostic approach for understanding the global system response functions operating in the Earth's upper atmosphere.

  8. Cardiac MR imaging: Comparison with echocardiography and dynamic CT

    International Nuclear Information System (INIS)

    Colletti, P.M.; Norris, S.; Raval, J.; Boswell, W.; Lee, K.; Ralls, P.; Haywood, J.; Halls, J.

    1986-01-01

    The authors compared gated cardiac MR imaging with two-dimensional and Doppler echocardiography and dynamic CT. Gated cardiac MR imaging (VISTA unit, 0.5 T) was performed in 55 patients with a variety of conditions. Accuracy of diagnosis was compared. CT showed arterial, valvular, and pericardial calcifications not seen on MR imaging. Many lesions were seen as well on CT as on MR imaging. Two-dimensional echocardiography was superior in demonstrating wall motion and valvular disease. MR imaging was superior in demonstrating myocardial structures

  9. Superior cycle performance of Sn-C/graphene nanocomposite as an anode material for lithium-ion batteries

    International Nuclear Information System (INIS)

    Liang Shuzhao; Zhu Xuefeng; Lian Peichao; Yang Weishen; Wang Haihui

    2011-01-01

    A novel anode material for lithium-ion batteries, tin nanoparticles coated with carbon embedded in graphene (Sn-C/graphene), was fabricated by hydrothermal synthesis and subsequent annealing. The structure and morphology of the nanocomposite were characterized by X-ray diffraction, scanning electron microscopy, and transmission electron microscopy. The size of the Sn-C nanoparticles is about 50-200 nm. The reversible specific capacity of the nanocomposite is ∼662 mAh g -1 at a specific current of 100 mA g -1 after 100 cycles, even ∼417 mAh g -1 at the high current of 1000 mA g -1 . These results indicate that Sn-C/graphene possesses superior cycle performance and high rate capability. The enhanced electrochemical performances can be ascribed to the characteristic structure of the nanocomposite with both of the graphene and carbon shells, which buffer the volume change of the metallic tin and prevent the detachment and agglomeration of pulverized tin. - Graphical abstract: Tin nanoparticles coated with carbon embedded in graphene have been successfully fabricated by hydrothermal synthesis and subsequent annealing. This nanocomposite as an anode material for lithium-ion batteries exhibits superior cycle performance. Highlights: → A novel Sn-C/graphene nanocomposite as an anode material for lithium-ion batteries. → Carbon coating and graphene improve the cycle performance of the Sn anode material. → Possess large capacity, superior cycle performance, and high rate capability.

  10. Preliminary assessment of the imaging capability of the YAP-(S)PET small animal scanner in neuroscience

    Energy Technology Data Exchange (ETDEWEB)

    Bartoli, Antonietta [Department of Physics ' E. Fermi' and Center of Excellence ' AmbiSEN' , University of Pisa, and INFN, Sezione di Pisa, Pisa I- 56127 (Italy)]. E-mail: bartoli@df.unipi.it; Belcari, Nicola [Department of Physics ' E. Fermi' and Center of Excellence ' AmbiSEN' , University of Pisa, and INFN, Sezione di Pisa, Pisa I- 56127 (Italy); Stark, Daniela [Institute of Nuclear Chemistry, University of Mainz, Mainz D-55099 (Germany); Hoehnemann, Sabine [Institute of Nuclear Chemistry, University of Mainz, Mainz D-55099 (Germany); Piel, Markus [Institute of Nuclear Chemistry, University of Mainz, Mainz D-55099 (Germany); Jennewein, Marc [Institute of Nuclear Chemistry, University of Mainz, Mainz D-55099 (Germany); Schmitt, Ulrich [Department of Psychiatry, University of Mainz, Mainz D-55099 (Germany); Tillmanns, Julia [Institute of Physiology and Pathophysiology, University of Mainz, Mainz D-55099 (Germany); Thews, Oliver [Institute of Physiology and Pathophysiology, University of Mainz, Mainz D-55099 (Germany); Hiemke, Christoph [Department of Psychiatry, University of Mainz, Mainz D-55099 (Germany); Roesch, Frank [Institute of Nuclear Chemistry, University of Mainz, Mainz D-55099 (Germany); Del Guerra, Alberto [Department of Physics ' E. Fermi' and Center of Excellence ' AmbiSEN' , University of Pisa, and INFN, Sezione di Pisa, Pisa I- 56127 (Italy)

    2006-12-20

    The new and fully engineered version of the YAP-(S)PET small animal scanner has been tested at the University of Mainz for preliminary assessment of its imaging capability for studies related to neuropharmacology and psychiatry. The main feature of the scanner is the capability to combine PET and SPECT techniques. It allows the development of new and interesting protocols for the investigation of many biological phenomena, more effectively than with PET or SPECT modalities alone. The scanner is made up of four detector heads, each one composed of a 4x4 cm{sup 2} of YAlO{sub 3}:Ce (or YAP:Ce) matrix, and has a field of view (FOV) of 4 cm axiallyx4 cm o transaxially. In PET mode, the volume resolution is less than 8 mm{sup 3} and is nearly constant over the whole FOV, while the sensitivity is about 2%. The SPECT performance is not so good, due to the presence of the multi-hole lead collimator in front of each head. Nevertheless, the YAP-PET scanner offers excellent resolution and sensitivity for performing on the availability of D2-like dopamine receptors on mice and rats in both PET and SPECT modalities.

  11. Superiority Of Graph-Based Visual Saliency GVS Over Other Image Segmentation Methods

    Directory of Open Access Journals (Sweden)

    Umu Lamboi

    2017-02-01

    Full Text Available Although inherently tedious the segmentation of images and the evaluation of segmented images are critical in computer vision processes. One of the main challenges in image segmentation evaluation arises from the basic conflict between generality and objectivity. For general segmentation purposes the lack of well-defined ground-truth and segmentation accuracy limits the evaluation of specific applications. Subjectivity is the most common method of evaluation of segmentation quality where segmented images are visually compared. This is daunting task however limits the scope of segmentation evaluation to a few predetermined sets of images. As an alternative supervised evaluation compares segmented images against manually-segmented or pre-processed benchmark images. Not only good evaluation methods allow for different comparisons but also for integration with target recognition systems for adaptive selection of appropriate segmentation granularity with improved recognition accuracy. Most of the current segmentation methods still lack satisfactory measures of effectiveness. Thus this study proposed a supervised framework which uses visual saliency detection to quantitatively evaluate image segmentation quality. The new benchmark evaluator uses Graph-based Visual Saliency GVS to compare boundary outputs for manually segmented images. Using the Berkeley Segmentation Database the proposed algorithm was tested against 4 other quantitative evaluation methods Probabilistic Rand Index PRI Variation of Information VOI Global Consistency Error GSE and Boundary Detection Error BDE. Based on the results the GVS approach outperformed any of the other 4 independent standard methods in terms of visual saliency detection of images.

  12. The Superior Fronto-Occipital Fasciculus in the Human Brain Revealed by Diffusion Spectrum Imaging Tractography: An Anatomical Reality or a Methodological Artifact?

    Science.gov (United States)

    Bao, Yue; Wang, Yong; Wang, Wei; Wang, Yibao

    2017-01-01

    The existence of the superior fronto-occipital fasciculus (SFOF) in the human brain remains controversial. The aim of the present study was to clarify the existence, course, and terminations of the SFOF. High angular diffusion spectrum imaging (DSI) analysis was performed on six healthy adults and on a template of 842 subjects from the Human Connectome Project. To verify tractography results, we performed fiber microdissections of four post-mortem human brains. Based on DSI tractography, we reconstructed the SFOF in the subjects and the template from the Human Connectome Project that originated from the rostral and medial parts of the superior and middle frontal gyri. By tractography, we found that the fibers formed a compact fascicle at the level of the anterior horn of the lateral ventricle coursing above the head of caudate nucleus, medial to the corona radiate and under the corpus callosum (CC), and terminated at the parietal region via the lower part of the caudate nucleus. We consider that this fiber bundle observed by tractography is the SFOF, although it terminates mainly at the parietal region, rather than occipital lobe. By contrast, we were unable to identify a fiber bundle corresponding to the SFOF in our fiber dissection study. Although we did not provide definite evidence of the SFOF in the human brain, these findings may be useful for future studies in this field. PMID:29321729

  13. The Superior Fronto-Occipital Fasciculus in the Human Brain Revealed by Diffusion Spectrum Imaging Tractography: An Anatomical Reality or a Methodological Artifact?

    Directory of Open Access Journals (Sweden)

    Yue Bao

    2017-12-01

    Full Text Available The existence of the superior fronto-occipital fasciculus (SFOF in the human brain remains controversial. The aim of the present study was to clarify the existence, course, and terminations of the SFOF. High angular diffusion spectrum imaging (DSI analysis was performed on six healthy adults and on a template of 842 subjects from the Human Connectome Project. To verify tractography results, we performed fiber microdissections of four post-mortem human brains. Based on DSI tractography, we reconstructed the SFOF in the subjects and the template from the Human Connectome Project that originated from the rostral and medial parts of the superior and middle frontal gyri. By tractography, we found that the fibers formed a compact fascicle at the level of the anterior horn of the lateral ventricle coursing above the head of caudate nucleus, medial to the corona radiate and under the corpus callosum (CC, and terminated at the parietal region via the lower part of the caudate nucleus. We consider that this fiber bundle observed by tractography is the SFOF, although it terminates mainly at the parietal region, rather than occipital lobe. By contrast, we were unable to identify a fiber bundle corresponding to the SFOF in our fiber dissection study. Although we did not provide definite evidence of the SFOF in the human brain, these findings may be useful for future studies in this field.

  14. Improvement of temporal and dynamic subtraction images on abdominal CT using 3D global image matching and nonlinear image warping techniques

    International Nuclear Information System (INIS)

    Okumura, E; Sanada, S; Suzuki, M; Takemura, A; Matsui, O

    2007-01-01

    Accurate registration of the corresponding non-enhanced and arterial-phase CT images is necessary to create temporal and dynamic subtraction images for the enhancement of subtle abnormalities. However, respiratory movement causes misregistration at the periphery of the liver. To reduce these misregistration errors, we developed a temporal and dynamic subtraction technique to enhance small HCC by 3D global matching and nonlinear image warping techniques. The study population consisted of 21 patients with HCC. Using the 3D global matching and nonlinear image warping technique, we registered current and previous arterial-phase CT images or current non-enhanced and arterial-phase CT images obtained in the same position. The temporal subtraction image was obtained by subtracting the previous arterial-phase CT image from the warped current arterial-phase CT image. The dynamic subtraction image was obtained by the subtraction of the current non-enhanced CT image from the warped current arterial-phase CT image. The percentage of fair or superior temporal subtraction images increased from 52.4% to 95.2% using the new technique, while on the dynamic subtraction images, the percentage increased from 66.6% to 95.2%. The new subtraction technique may facilitate the diagnosis of subtle HCC based on the superior ability of these subtraction images to show nodular and/or ring enhancement

  15. Digital stereoscopic imaging

    Science.gov (United States)

    Rao, A. Ravishankar; Jaimes, Alejandro

    1999-05-01

    The convergence of inexpensive digital cameras and cheap hardware for displaying stereoscopic images has created the right conditions for the proliferation of stereoscopic imagin applications. One application, which is of growing importance to museums and cultural institutions, consists of capturing and displaying 3D images of objects at multiple orientations. In this paper, we present our stereoscopic imaging system and methodology for semi-automatically capturing multiple orientation stereo views of objects in a studio setting, and demonstrate the superiority of using a high resolution, high fidelity digital color camera for stereoscopic object photography. We show the superior performance achieved with the IBM TDI-Pro 3000 digital camera developed at IBM Research. We examine various choices related to the camera parameters, image capture geometry, and suggest a range of optimum values that work well in practice. We also examine the effect of scene composition and background selection on the quality of the stereoscopic image display. We will demonstrate our technique with turntable views of objects from the IBM Corporate Archive.

  16. HTLV-I carrier with unusual brain MR imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Yata, Shinsaku; Ogawa, Toshihide; Sugihara, Shuji; Matsusue, Eiji; Fujii, Shinya; Kinoshita, Toshibumi [Tottori University, Department of Pathophysiological and Therapeutic Science, Yonago (Japan); Faculty of Medicine, Tottori University, Yonago (Japan)

    2004-09-01

    We describe unusual brain MR imaging findings in a patient who is an HTLV-I carrier without myelopathy. T2-weighted MR images showed hyperintense signal abnormalities in the pyramidal tract, superior and middle cerebellar peduncles, and decussation of the superior cerebellar peduncles, in addition to subcortical white matter involvement. Diffusion-weighted images also showed hyperintense signal abnormalities in the same regions by T2 shine-through effect. (orig.)

  17. Tratamento da síndrome da veia cava superior Treatment of superior vena cava syndrome

    Directory of Open Access Journals (Sweden)

    Luís Marcelo Inaco Cirino

    2005-12-01

    Full Text Available A veia cava superior é formada pela união das duas veias inominadas, direita e esquerda, e localiza-se no mediastino médio, à direita da artéria aorta e anteriormente à traquéia. A síndrome da veia cava superior representa um conjunto de sinais (dilatação das veias do pescoço, pletora facial, edema de membros superiores, cianose e sintomas (cefaléia, dispnéia, tosse, edema de membro superior, ortopnéia e disfagia decorrentes da obstrução do fluxo sanguíneo através da veia cava superior em direção ao átrio direito. A obstrução pode ser causada por compressão extrínseca, invasão tumoral, trombose ou por dificuldade do retorno venoso ao coração secundária a doenças intra-atriais ou intraluminais. Aproximadamente 73% a 97% dos casos de síndrome da veia cava superior ocorrem durante a evolução de processos malignos intratorácicos. A maioria dos pacientes com a síndrome secundária a neoplasias malignas é tratada sem necessidade de cirurgia, através de radioterapia ou quimioterapia, ou através da colocação de stents endoluminais. Quando a síndrome é de etiologia benigna, o tratamento é feito através de medidas clínicas (anticoagulação, elevação da cabeça, etc. ou, em casos refratários, através de angioplastia, colocação de stents endoluminais e cirurgia.The superior vena cava is formed by the union of the right and left brachiocephalic veins. It is located in the middle mediastinum, to the right of the aorta and anterior to the trachea. Superior vena cava syndrome consists of a group of signs (dilation of the veins in the neck, facial swelling, edema of the upper limbs, and cyanosis and symptoms (headache, dyspnea, cough, orthopnea and dysphagia caused by the obstruction of blood flow through the superior vena cava to the right atrium. This obstruction can be caused by extrinsic compression, tumor invasion or thrombosis. Such obstruction may also occur as a result of insufficient venous return

  18. Kompetisi Stasiun Televisi Swasta Nasional Berdasarkan Superiority Direction dan Superiority Magnitude

    Directory of Open Access Journals (Sweden)

    Anastasia Winanti Riesardhy

    2013-11-01

    Full Text Available Abstract: Uses and gratification theory is employed particularly as the teoritical frame of the research to examine the extent to which ten national television stations compete to satisfy Indonesian audiences. In particular, two main concepts of that theory namely audiences “gratification sought and gratifications obtained, are broken down and counted based on superiority direction and superiority magnitude. In general, the findings show that those televisions have satisfied their audiences, although in terms of gratifications to dispersal motives, they haven’t satisfied as much as it was expected. Significant competition occurs between TRANSTV and TRANS7, RCTI and SCTV, and TVONE and METROTV. TVONE become the most satisfiyng television station. Abstrak: Teori Uses & Gratification menjadi dasar penelitian ini untuk mengukur bagaimana kompetisi yang terjadi di antara sepuluh stasiun televisi yang bersiaran secara nasional di Indonesia. Aplikasi dari teori tersebut dimunculkan dalam konsep kepuasan yang diharapkan dan kepuasan yang diperoleh ketika menonton acara televisi dan didasarkan pada penghitungan superiority direction dan superiority magnitude. Sepuluh stasiun televisi yang diteliti telah dapat memuaskan audiensnya, meskipun untuk kepuasan atas motif pengalihan masih belum dapat melampaui kepuasan yang diharapkan. Kompetisi yang signifikan terjadi antara TRANSTV dengan TRANS7, RCTI dengan SCTV serta TVONE dengan METROTV. TVONE menjadi stasiun televisi yang menduduki peringkat pertama dalam memberikan kepuasan tertinggi kepada audiens.

  19. Iterative feature refinement for accurate undersampled MR image reconstruction

    Science.gov (United States)

    Wang, Shanshan; Liu, Jianbo; Liu, Qiegen; Ying, Leslie; Liu, Xin; Zheng, Hairong; Liang, Dong

    2016-05-01

    Accelerating MR scan is of great significance for clinical, research and advanced applications, and one main effort to achieve this is the utilization of compressed sensing (CS) theory. Nevertheless, the existing CSMRI approaches still have limitations such as fine structure loss or high computational complexity. This paper proposes a novel iterative feature refinement (IFR) module for accurate MR image reconstruction from undersampled K-space data. Integrating IFR with CSMRI which is equipped with fixed transforms, we develop an IFR-CS method to restore meaningful structures and details that are originally discarded without introducing too much additional complexity. Specifically, the proposed IFR-CS is realized with three iterative steps, namely sparsity-promoting denoising, feature refinement and Tikhonov regularization. Experimental results on both simulated and in vivo MR datasets have shown that the proposed module has a strong capability to capture image details, and that IFR-CS is comparable and even superior to other state-of-the-art reconstruction approaches.

  20. Iterative feature refinement for accurate undersampled MR image reconstruction

    International Nuclear Information System (INIS)

    Wang, Shanshan; Liu, Jianbo; Liu, Xin; Zheng, Hairong; Liang, Dong; Liu, Qiegen; Ying, Leslie

    2016-01-01

    Accelerating MR scan is of great significance for clinical, research and advanced applications, and one main effort to achieve this is the utilization of compressed sensing (CS) theory. Nevertheless, the existing CSMRI approaches still have limitations such as fine structure loss or high computational complexity. This paper proposes a novel iterative feature refinement (IFR) module for accurate MR image reconstruction from undersampled K-space data. Integrating IFR with CSMRI which is equipped with fixed transforms, we develop an IFR-CS method to restore meaningful structures and details that are originally discarded without introducing too much additional complexity. Specifically, the proposed IFR-CS is realized with three iterative steps, namely sparsity-promoting denoising, feature refinement and Tikhonov regularization. Experimental results on both simulated and in vivo MR datasets have shown that the proposed module has a strong capability to capture image details, and that IFR-CS is comparable and even superior to other state-of-the-art reconstruction approaches. (paper)

  1. Evaluation of three imaging instruments in dogs with liver hematomas: concise communication

    International Nuclear Information System (INIS)

    Frick, M.P.; Knight, L.C.; Ponto, R.A.; Loken, M.K.

    1979-01-01

    Single-gamma emission computerized tomography (ECT) was compared with transmission computerized tomography (TCT) and scintillation-camera imaging (SC) in eight dogs with acute, solitary hematomas in the left liver lobe. The superior performance of TCT was attributed to its inherently better spatial resolution than those of ECT or SC, and to the fact that studies with TCT could be performed during apnea. ECT was more sensitive than SC to small changes in the spatial distribution of radionuclides. In addition, the ECT, by virtue of its sectioning capability, was more sensitive than is SC to differences in radionuclide concentrations at the same depth in an organ

  2. Comparison of STIR turbo SE imaging and diffusion-weighted imaging of the lung: capability for detection and subtype classification of pulmonary adenocarcinomas

    Energy Technology Data Exchange (ETDEWEB)

    Koyama, Hisanobu; Ohno, Yoshiharu; Onishi, Yumiko; Matsumoto, Keiko; Nogami, Munenobu; Takenaka, Daisuke; Sugimura, Kazuro [Kobe University Graduate School of Medicine, Department of Radiology, Kobe, Hyogo (Japan); Aoyama, Nobukazu [Kobe University Hospital, Division of Radiology, Kobe (Japan); Nishio, Wataru [Kobe University Graduate School of Medicine, Division of Cardiovascular, Thoracic and Pediatric Surgery, Kobe (Japan); Ohbayashi, Chiho [Hyogo Cancer Center, Division of Pathology, Akashi (Japan)

    2010-04-15

    The aim of the study was to evaluate the diagnostic performance of diffusion-weighted imaging (DWI) for detection and subtype classification in pulmonary adenocarcinomas through comparison with short TI inversion recovery turbo spin-echo imaging sequence (STIR). Thirty-two patients (mean age, 65.2 years) with 33 adenocarcinomas (mean diameter, 27.6 mm) were enrolled in this study. The detection rates of both sequences were compared. The ADC values on DWI and the contrast ratio (CR) between cancer and muscle on STIR were measured and those were compared across subtype classifications. Finally, ROC-based positive tests were performed to differentiate subtype classifications, and differentiation capabilities were compared. The DWI detection rate [85% (28/33)] was significantly lower than that of STIR [100% (33/33), P < 0.05]. The ADC values showed no significant difference regarding subtype classification; however, the CRs of bronchio-alveolar carcinomas (BACs) were significantly lower than those of other types (P < 0.05). When threshold values for differentiating BACs from others were adapted, the sensitivity and accuracy of DWI were significantly lower than those of STIR (P < 0.05). For differentiating adenocarcinomas with mixed subtypes from those with no BA component, there were no significant differences between the two sequences. STIR is more sensitive for detection and subtype classification than DWI. (orig.)

  3. MR imaging of congenital heart diseases in adolescents and adults

    Energy Technology Data Exchange (ETDEWEB)

    Choe, Yeon Hyeon; Kang, I Seok; Park, Seung Woo; Lee, Heung Jae [Sungkwunkwan University School of Medicine, Seoul (Korea, Republic of)

    2001-09-01

    Echocardiography and catheterization angiography suffer certain limitations in the evaluation of congenital heart diseases in adults, though these are overcome by MRI, in which a wide field-of view, unlimited multiplanar imaging capability and three-dimensional contrast-enhanced MR angiography techniques are used. In adults, recently introduced fast imaging techniques provide cardiac MR images of sufficient quality and with less artifacts. Ventricular volume, ejection fraction, and vascular flow measurements, including pressure gradients and pulmonary-to-systemic flow ratio, can be calculated or obtained using fast cine MRI, phase-contrast MR flow-velocity mapping, and semiautomatic analysis software. MRI is superior to echocardiography in diagnosing partial anomalous pulmonary venous connection, unroofed coronary sinus, anomalies of the pulmonary arteries, aorta and systemic veins, complex heart diseases, and postsurgical sequelae. Biventricular function is reliably evaluated with cine MRI after repair of tetralogy of Fallot, and Senning's and Mustard's operations. MRI has an important and growing role in the morphologic and functional assessment of congenital heart diseases in adolescents and adults.

  4. Aircraft and satellite monitoring of water quality in Lake Superior near Duluth

    Science.gov (United States)

    Scherz, J. P.; Sydor, M.; Vandomelen, J. F.

    1974-01-01

    Satellite images and low altitude aerial photographs often show vivid discolorations in water bodies. Extensive laboratory analysis shows that water reflectance, which causes brightness on aerial images, positively correlates to the water quality parameter of turbidity, which on a particular day correlates to suspended solids. Work with low altitude photography on three overcast days and with ERTS images on five clear days provides positive correlation of image brightness to the high turbidity and solids which are present in Lake Superior near Duluth over 50% of the time. Proper use of aerial images would have shown that an $8,000,000 drinking water intake constructed in the midst of this unpotable, turbid water should have been located 6 miles north in clear, usable water. Noise effects such as skylight reflection, atmospheric effects, and depth penetration also must be understood for operational use of remote sensing for water quality monitoring and are considered in the paper.

  5. Information Superiority through Data Warehousing

    National Research Council Canada - National Science Library

    Warner, Neil

    2001-01-01

    .... A precursor to a knowledge edge is Information Superiority. Within most current Command Support Systems minimal integration and fusion of data is undertaken to provide the basis of information superiority...

  6. Uniform Fe3O4 microflowers hierarchical structures assembled with porous nanoplates as superior anode materials for lithium-ion batteries

    DEFF Research Database (Denmark)

    Wang, Xiaoliang; Liu, Yanguo; Arandiyan, Hamidreza

    2016-01-01

    as anode material for lithium-ion batteries, the as-prepared Fe3O4 microflowers electrodes delivered superior capacity, better cycling stability and rate capability than that of Fe3O4 microspheres electrodes. The improved electrochemical performance was attributed to the microscale flowerlike architecture...

  7. An Object-Based Image Analysis Approach for Detecting Penguin Guano in very High Spatial Resolution Satellite Images

    Directory of Open Access Journals (Sweden)

    Chandi Witharana

    2016-04-01

    Full Text Available The logistical challenges of Antarctic field work and the increasing availability of very high resolution commercial imagery have driven an interest in more efficient search and classification of remotely sensed imagery. This exploratory study employed geographic object-based analysis (GEOBIA methods to classify guano stains, indicative of chinstrap and Adélie penguin breeding areas, from very high spatial resolution (VHSR satellite imagery and closely examined the transferability of knowledge-based GEOBIA rules across different study sites focusing on the same semantic class. We systematically gauged the segmentation quality, classification accuracy, and the reproducibility of fuzzy rules. A master ruleset was developed based on one study site and it was re-tasked “without adaptation” and “with adaptation” on candidate image scenes comprising guano stains. Our results suggest that object-based methods incorporating the spectral, textural, spatial, and contextual characteristics of guano are capable of successfully detecting guano stains. Reapplication of the master ruleset on candidate scenes without modifications produced inferior classification results, while adapted rules produced comparable or superior results compared to the reference image. This work provides a road map to an operational “image-to-assessment pipeline” that will enable Antarctic wildlife researchers to seamlessly integrate VHSR imagery into on-demand penguin population census.

  8. Diffraction-enhanced imaging of the rat spine

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, M.E. [Cleveland Clinic, Dept. of Neurosurgery, Cleveland, Ohio (United States)]. E-mail: mebkelly@gmail.com; Beavis, R.C. [Univ. of Saskatchewan, Royal Univ. Hospital, Div. of Orthopaedic Surgery, Saskatoon, Saskatchewan (Canada); Fourney, D.R. [Univ. of Saskatchewan, Royal Univ. Hospital, Div. of Neurosurgery, Saskatoon, Saskatchewan (Canada); Schultke, E. [Univ. of Saskatchewan, Dept. of Anatomy and Cell Biology, Saskatoon, Saskatchewan (Canada); Parham, C. [Univ. of North Carolina, Dept. of Biomedical Engineering, Chapel Hill, North Carolina (United States); Juurlink, B.H. [Univ. of Saskatchewan, Dept. of Anatomy and Cell Biology, Saskatoon, Saskatchewan (Canada); Zhong, Z. [Brookhaven National Laboratory, National Synchrotron Light Source, Upton, New York (United States); Chapman, L.D. [Univ. of Saskatchewan, Dept. of Anatomy and Cell Biology, Saskatoon, Saskatchewan (Canada)

    2006-10-15

    Diffraction-enhanced imaging (DEI) uses monochromatic synchrotron X-rays to image tissue. This technique has been shown to produce superior bony and soft tissue characterization when compared with conventional absorption radiography. Application of this imaging modality is under investigation, and this study represents the first DEI analysis of the vertebral column. Four male Wistar rats were studied. Spine muscle blocks were imaged in 3 of the rats after thoracic laminectomy (n = 1), after lumbar laminectomy (n = 1), and in a control condition (n = 1). The fourth rat was imaged as a whole animal control. Conventional radiography and synchrotron-supported DEI at 40 keV were performed on all specimens. We compared images side by side, using a nonvalidated subjective assessment technique. DEI produced superior visualization of the vertebral anatomy, compared with conventional absorption radiography for all specimens. Greater bony and soft tissue detail was noted, with improved image contrast. In addition to imaging the anatomical structures, DEI showed the polyglactin suture material used for fascial closure in the 2 animals that underwent surgery. Artifact from air bubbles was present on DEI images but not on plain radiographs. This represents the first use of DEI, a novel imaging modality, to image the vertebral column. It provides excellent anatomic detail with superior contrast and visualization of both bone and soft tissue when compared with conventional radiography. Future applications of this investigational technique may include analysis of spinal fusion as well as degenerative and neoplastic conditions of the spine. (author)

  9. Diffraction-enhanced imaging of the rat spine

    International Nuclear Information System (INIS)

    Kelly, M.E.; Beavis, R.C.; Fourney, D.R.; Schultke, E.; Parham, C.; Juurlink, B.H.; Zhong, Z.; Chapman, L.D.

    2006-01-01

    Diffraction-enhanced imaging (DEI) uses monochromatic synchrotron X-rays to image tissue. This technique has been shown to produce superior bony and soft tissue characterization when compared with conventional absorption radiography. Application of this imaging modality is under investigation, and this study represents the first DEI analysis of the vertebral column. Four male Wistar rats were studied. Spine muscle blocks were imaged in 3 of the rats after thoracic laminectomy (n = 1), after lumbar laminectomy (n = 1), and in a control condition (n = 1). The fourth rat was imaged as a whole animal control. Conventional radiography and synchrotron-supported DEI at 40 keV were performed on all specimens. We compared images side by side, using a nonvalidated subjective assessment technique. DEI produced superior visualization of the vertebral anatomy, compared with conventional absorption radiography for all specimens. Greater bony and soft tissue detail was noted, with improved image contrast. In addition to imaging the anatomical structures, DEI showed the polyglactin suture material used for fascial closure in the 2 animals that underwent surgery. Artifact from air bubbles was present on DEI images but not on plain radiographs. This represents the first use of DEI, a novel imaging modality, to image the vertebral column. It provides excellent anatomic detail with superior contrast and visualization of both bone and soft tissue when compared with conventional radiography. Future applications of this investigational technique may include analysis of spinal fusion as well as degenerative and neoplastic conditions of the spine. (author)

  10. Gallium SPECT detection of neoplastic intravascular obstruction of the superior vena cava

    International Nuclear Information System (INIS)

    Swayne, L.C.; Kaplan, I.L.

    1989-01-01

    A rare case of an intravascular neoplastic obstruction of the superior vena cava is discussed. The lesion was detected with gallium single photon emission computed tomography (SPECT) despite a normal appearance on a concurrent radiographic CT study. A computer-generated composite SPECT-CT image confirmed the intravascular localization of the radioisotope, and a subsequent CT-guided transthoracic needle biopsy revealed a poorly differentiated adenocarcinoma

  11. A case of timely satellite image acquisitions in support of coastal emergency environmental response management

    Science.gov (United States)

    Ramsey, Elijah W.; Werle, Dirk; Lu, Zhong; Rangoonwala, Amina; Suzuoki, Yukihiro

    2009-01-01

    The synergistic application of optical and radar satellite imagery improves emergency response and advance coastal monitoring from the realm of “opportunistic” to that of “strategic.” As illustrated by the Hurricane Ike example, synthetic aperture radar imaging capabilities are clearly applicable for emergency response operations, but they are also relevant to emergency environmental management. Integrated with optical monitoring, the nearly real-time availability of synthetic aperture radar provides superior consistency in status and trends monitoring and enhanced information concerning causal forces of change that are critical to coastal resource sustainability, including flooding extent, depth, and frequency.

  12. Human middle longitudinal fascicle: segregation and behavioral-clinical implications of two distinct fiber connections linking temporal pole and superior temporal gyrus with the angular gyrus or superior parietal lobule using multi-tensor tractography.

    Science.gov (United States)

    Makris, N; Preti, M G; Wassermann, D; Rathi, Y; Papadimitriou, G M; Yergatian, C; Dickerson, B C; Shenton, M E; Kubicki, M

    2013-09-01

    The middle longitudinal fascicle (MdLF) is a major fiber connection running principally between the superior temporal gyrus and the parietal lobe, neocortical regions of great biological and clinical interest. Although one of the most prominent cerebral association fiber tracts, it has only recently been discovered in humans. In this high angular resolution diffusion imaging (HARDI) MRI study, we delineated the two major fiber connections of the human MdLF, by examining morphology, topography, cortical connections, biophysical measures, volume and length in seventy-four brains. These two fiber connections course together through the dorsal temporal pole and the superior temporal gyrus maintaining a characteristic topographic relationship in the mediolateral and ventrodorsal dimensions. As these pathways course towards the parietal lobe, they split to form separate fiber pathways, one following a ventrolateral trajectory and connecting with the angular gyrus and the other following a dorsomedial route and connecting with the superior parietal lobule. Based on the functions of their cortical affiliations, we suggest that the superior temporal-angular connection of the MdLF, i.e., STG(MdLF)AG plays a role in language and attention, whereas the superior temporal-superior parietal connection of the MdLF, i.e., STG(MdLF)SPL is involved in visuospatial and integrative audiovisual functions. Furthermore, the MdLF may have clinical implications in neurodegenerative disorders such as primary progressive aphasia, frontotemporal dementia, posterior cortical atrophy, corticobulbar degeneration and Alzheimer's disease as well as attention-deficit/hyperactivity disorder and schizophrenia.

  13. The construction of hierarchical structure on Ti substrate with superior osteogenic activity and intrinsic antibacterial capability

    Science.gov (United States)

    Huang, Ying; Zha, Guangyu; Luo, Qiaojie; Zhang, Jianxiang; Zhang, Feng; Li, Xiaohui; Zhao, Shifang; Zhu, Weipu; Li, Xiaodong

    2014-01-01

    The deficient osseointegration and implant-associated infections are pivotal issues for the long-term clinical success of endosteal Ti implants, while development of functional surfaces that can simultaneously overcome these problems remains highly challenging. This study aimed to fabricate sophisticated Ti implant surface with both osteogenic inducing activity and inherent antibacterial ability simply via tailoring surface topographical features. Micro/submciro/nano-scale structure was constructed on Ti by three cumulative subtractive methods, including sequentially conducted sandblasting as well as primary and secondary acid etching treatment. Topographical features of this hierarchical structure can be well tuned by the time of the secondary acid treatment. Ti substrate with mere micro/submicro-scale structure (MS0-Ti) served as a control to examine the influence of hierarchical structures on surface properties and biological activities. Surface analysis indicated that all hierarchically structured surfaces possessed exactly the same surface chemistry as that of MS0-Ti, and all of them showed super-amphiphilicity, high surface free energy, and high protein adsorption capability. Biological evaluations revealed surprisingly antibacterial ability and excellent osteogenic activity for samples with optimized hierarchical structure (MS30-Ti) when compared with MS0-Ti. Consequently, for the first time, a hierarchically structured Ti surface with topography-induced inherent antibacterial capability and excellent osteogenic activity was constructed. PMID:25146099

  14. Mondini-like malformation mimicking otosclerosis and superior semicircular canal dehiscence.

    Science.gov (United States)

    Karlberg, M; Annertz, M; Magnusson, M

    2006-05-01

    In 2003, it was reported that superior semicircular canal dehiscence can mimic otosclerosis because of low-frequency bone conduction hearing gain and dissipation of air-conducted acoustic energy through the dehiscence. We report the case of a 17-year-old girl with left-sided combined hearing loss thought to be due to otosclerosis. Bone conduction thresholds were -10 dB at 250 and 500 Hz and she had a 40 dB air-bone gap at 250 Hz. When a tuning fork was placed at her ankle she heard it in her left ear. Acoustic reflexes and vestibular evoked myogenic potentials could be elicited bilaterally. Imaging of the temporal bones showed no otosclerosis, superior semicircular canal dehiscence or large vestibular aqueduct, but a left-sided, Mondini-like dysplasia of the cochlea with a modiolar deficiency could be seen. Mondini-like cochlear dysplasia should be added to the causes of inner-ear conductive hearing loss.

  15. Infection imaging in nuclear medicine

    African Journals Online (AJOL)

    osteomyelitis, particularly in children without previous trauma to their ... Anatomical imaging (such as X-rays, ... bacterial pneumonia, whereas diffuse ... imaging is superior to Ga-67 for the detection ... Clinical value of FDG PET in patients with.

  16. Use of a laser-induced fluorescence thermal imaging system for film cooling heat transfer measurement

    Energy Technology Data Exchange (ETDEWEB)

    Chyu, M.K. [Carnegie Mellon Univ., Pittsburgh, PA (United States)

    1995-10-01

    This paper describes a novel approach based on fluorescence imaging of thermographic phosphor that enables the simultaneous determination of both local film effectiveness and local heat transfer on a film-cooled surface. The film cooling model demonstrated consists of a single row of three discrete holes on a flat plate. The transient temperature measurement relies on the temperature-sensitive fluorescent properties of europium-doped lanthanum oxysulfide (La{sub 2}O{sub 2}S:EU{sup 3+}) thermographic phosphor. A series of full-field surface temperatures, mainstream temperatures, and coolant film temperatures were acquired during the heating of a test surface. These temperatures are used to calculate the heat transfer coefficients and the film effectiveness simultaneously. Because of the superior spatial resolution capability for the heat transfer data reduced from these temperature frames, the laser-induced fluorescence (LIF) imaging system, the present study observes the detailed heat transfer characteristics over a film-protected surface. The trend of the results agrees with those obtained using other conventional thermal methods, as well as the liquid crystal imaging technique. One major advantage of this technique is the capability to record a large number of temperature frames over a given testing period. This offers multiple-sample consistency.

  17. MR imaging of acute hemorrhagic brain infarction

    International Nuclear Information System (INIS)

    Uchino, Akira; Ohnari, Norihiro; Ohno, Masato

    1989-01-01

    Six patients with acute hemorrhagic brain infarct were imaged using spin-echo (SE) pulse sequences on a 1.5 Tesla MR scanner. Including two patients with repeated MR imaging, a total of eight examinations, all performed within 15 days after stroke, were analyzed retrospectively. Four patients revealed massive hemorrhages in the basal ganglia or cerebellum and three cases demonstrated multiple linear hemorrhages in the cerebral cortex. On T1-weighted images, hemorrhages were either mildly or definitely hyperintense relative to gray matter, while varied from mildly hypointense to hyperintense on T2-weighted images. T1-weighted images were superior to T2-weighted images in detection of hemorrhgage. CT failed to detect hemorrhage in two of five cases: indicative of MR superiority to CT in the diagnosis of acute hemorrhagic infarcts. (author)

  18. Exploring imaging capabilities of the extended prestack wavefield

    KAUST Repository

    Alkhalifah, Tariq Ali

    2013-08-19

    The dynamic form of the double square-root (DSR) equation provides a mechanism to extrapolate prestack wavefields by moving the sources and receivers in space with respect to a potential image (scatterer) point. Its classical implementation for imaging often assumes sources and receivers are at the same horizontal surface. Reverse time migration (RTM), as well as common shot migrations in general, through its separate treatment of the sources and receivers, allows for more exibility in source and receiver configurations. A simple modication to the classical DSR equation provides such exibility. Specically, we define a 7-dimensional prestack wavefield for 3-D media that includes the vertical source and receiver offset. The corresponding dispersion relation can be used to extrapolate such wavefields. However, the cost for such a definition and extrapolation can be prohibitive, considering the high dimensionality of the problem. We reduce the dimensionality by recognizing that the sources and receivers often share the same horizontal plane, and thus, obtain the conventional DSR formulation. An efficient implementation of DSR in time yields extrapolation speeds that nominally exceed those obtained from reverse time migration. We can also reduce the dimensionality by setting the horizontal offset between the source and receiver at the image point to zero, or using a DSR-like formulation to correct for source-receiver vertical offset or topography.

  19. Exploring imaging capabilities of the extended prestack wavefield

    KAUST Repository

    Alkhalifah, Tariq Ali; Wu, Zedong; Fomel, Sergey

    2013-01-01

    The dynamic form of the double square-root (DSR) equation provides a mechanism to extrapolate prestack wavefields by moving the sources and receivers in space with respect to a potential image (scatterer) point. Its classical implementation for imaging often assumes sources and receivers are at the same horizontal surface. Reverse time migration (RTM), as well as common shot migrations in general, through its separate treatment of the sources and receivers, allows for more exibility in source and receiver configurations. A simple modication to the classical DSR equation provides such exibility. Specically, we define a 7-dimensional prestack wavefield for 3-D media that includes the vertical source and receiver offset. The corresponding dispersion relation can be used to extrapolate such wavefields. However, the cost for such a definition and extrapolation can be prohibitive, considering the high dimensionality of the problem. We reduce the dimensionality by recognizing that the sources and receivers often share the same horizontal plane, and thus, obtain the conventional DSR formulation. An efficient implementation of DSR in time yields extrapolation speeds that nominally exceed those obtained from reverse time migration. We can also reduce the dimensionality by setting the horizontal offset between the source and receiver at the image point to zero, or using a DSR-like formulation to correct for source-receiver vertical offset or topography.

  20. Quantification of tumor fluorescence during intraoperative optical cancer imaging.

    Science.gov (United States)

    Judy, Ryan P; Keating, Jane J; DeJesus, Elizabeth M; Jiang, Jack X; Okusanya, Olugbenga T; Nie, Shuming; Holt, David E; Arlauckas, Sean P; Low, Phillip S; Delikatny, E James; Singhal, Sunil

    2015-11-13

    Intraoperative optical cancer imaging is an emerging technology in which surgeons employ fluorophores to visualize tumors, identify tumor-positive margins and lymph nodes containing metastases. This study compares instrumentation to measure tumor fluorescence. Three imaging systems (Spectropen, Glomax, Flocam) measured and quantified fluorescent signal-to-background ratios (SBR) in vitro, murine xenografts, tissue phantoms and clinically. Evaluation criteria included the detection of small changes in fluorescence, sensitivity of signal detection at increasing depths and practicality of use. In vitro, spectroscopy was superior in detecting incremental differences in fluorescence than luminescence and digital imaging (Ln[SBR] = 6.8 ± 0.6, 2.4 ± 0.3, 2.6 ± 0.1, p = 0.0001). In fluorescent tumor cells, digital imaging measured higher SBRs than luminescence (6.1 ± 0.2 vs. 4.3 ± 0.4, p = 0.001). Spectroscopy was more sensitive than luminometry and digital imaging in identifying murine tumor fluorescence (SBR = 41.7 ± 11.5, 5.1 ± 1.8, 4.1 ± 0.9, p = 0.0001), and more sensitive than digital imaging at detecting fluorescence at increasing depths (SBR = 7.0 ± 3.4 vs. 2.4 ± 0.5, p = 0.03). Lastly, digital imaging was the most practical and least time-consuming. All methods detected incremental differences in fluorescence. Spectroscopy was the most sensitive for small changes in fluorescence. Digital imaging was the most practical considering its wide field of view, background noise filtering capability, and sensitivity to increasing depth.

  1. Focal switching of photochromic fluorescent proteins enables multiphoton microscopy with superior image contrast.

    Science.gov (United States)

    Kao, Ya-Ting; Zhu, Xinxin; Xu, Fang; Min, Wei

    2012-08-01

    Probing biological structures and functions deep inside live organisms with light is highly desirable. Among the current optical imaging modalities, multiphoton fluorescence microscopy exhibits the best contrast for imaging scattering samples by employing a spatially confined nonlinear excitation. However, as the incident laser power drops exponentially with imaging depth into the sample due to the scattering loss, the out-of-focus background eventually overwhelms the in-focus signal, which defines a fundamental imaging-depth limit. Herein we significantly improve the image contrast for deep scattering samples by harnessing reversibly switchable fluorescent proteins (RSFPs) which can be cycled between bright and dark states upon light illumination. Two distinct techniques, multiphoton deactivation and imaging (MPDI) and multiphoton activation and imaging (MPAI), are demonstrated on tissue phantoms labeled with Dronpa protein. Such a focal switch approach can generate pseudo background-free images. Conceptually different from wave-based approaches that try to reduce light scattering in turbid samples, our work represents a molecule-based strategy that focused on imaging probes.

  2. Imaging capabilities of SXT for Solar-A

    Science.gov (United States)

    Lemen, J. R.; Acton, L. W.; Brown, W. A.; Bruner, M. E.; Catura, R. C.

    1991-01-01

    The present study characterizes the Soft X-ray Telescope (SXT), a grazing-incidence solar X-ray telescope which will be flown on the Japanese Solar-A satellite. X-ray tests showed that the SXT mirror meets or exceeds design requirements. SXT advantages over Skylab are: improved time resolution (not less than 0.5 s), greatly decreased mirror scatter, coaligned aspect telescope to intersperse images of sunspots and magnetic plage, and digital data readout.

  3. The superior vena cava syndrome caused by malignant disease

    International Nuclear Information System (INIS)

    Eren, Suat; Karaman, Adem; Okur, Adnan

    2006-01-01

    Objective: The superior vena cava (SVC) obstruction by malignant diseases is either by direct invasion and compression or by tumour thrombus of the SVC. Whatever is its cause, obstruction of the SVC causes elevated pressure in the veins draining into the SVC and increased or reversed blood flow through collateral vessels. Severity of the syndrome depends on the collateral vascular system development. Therefore, imaging of the collateral veins with variable location and connection is important in determining the extension and management of the disease. Our aims are to describe collateral vessels of the superior vena cava syndrome (SVCS) related with the malignant diseases and to assess the ability of multi-detector row CT with multiplanar and 3D volume rendering techniques in determining and describing collateral circulations. Materials and methods: We present CT angiography findings of seven patients with small cell carcinoma of the lung (n = 2), squamous cell carcinoma of the lung (n = 3), Hodgkin disease of the thorax (n = 1), and squamous cell carcinoma of the oesophagus (n = 1). The patients received contrast-enhanced CT scans of the chest and abdomen on a multi-detector row CT during breath holding at suspended inspiration. Results: CT images revealed the cause and level of the SVC obstruction in all patients with axial and multiplanar reconstructed images. The SVC showed total obstruction in five patients and partial obstruction in two patients. The most common experienced collateral vessels were azygos vein (6), intercostal veins (6), mediastinal veins (6), paravertebral veins (5), hemiazygos vein (5), thoracoepigastric vein (5), internal mammary vein (5), thoracoacromioclavicular venous plexus (5), and anterior chest wall veins (5). While one case showed the portal-systemic shunt, V. cordis media and sinus coronarius with phrenic veins were enlarged in two cases, and the left adrenal vein was enlarged in a patient. In one case, the azygos vein with reversed

  4. The superior vena cava syndrome caused by malignant disease

    Energy Technology Data Exchange (ETDEWEB)

    Eren, Suat [Department of Radiology, Faculty of Medicine, Atatuerk University, 25240 Erzurum (Turkey)]. E-mail: suateren@atauni.edu.tr; Karaman, Adem [Department of Radiology, Faculty of Medicine, Atatuerk University, 25240 Erzurum (Turkey); Okur, Adnan [Department of Radiology, Faculty of Medicine, Atatuerk University, 25240 Erzurum (Turkey)

    2006-07-15

    Objective: The superior vena cava (SVC) obstruction by malignant diseases is either by direct invasion and compression or by tumour thrombus of the SVC. Whatever is its cause, obstruction of the SVC causes elevated pressure in the veins draining into the SVC and increased or reversed blood flow through collateral vessels. Severity of the syndrome depends on the collateral vascular system development. Therefore, imaging of the collateral veins with variable location and connection is important in determining the extension and management of the disease. Our aims are to describe collateral vessels of the superior vena cava syndrome (SVCS) related with the malignant diseases and to assess the ability of multi-detector row CT with multiplanar and 3D volume rendering techniques in determining and describing collateral circulations. Materials and methods: We present CT angiography findings of seven patients with small cell carcinoma of the lung (n = 2), squamous cell carcinoma of the lung (n = 3), Hodgkin disease of the thorax (n = 1), and squamous cell carcinoma of the oesophagus (n = 1). The patients received contrast-enhanced CT scans of the chest and abdomen on a multi-detector row CT during breath holding at suspended inspiration. Results: CT images revealed the cause and level of the SVC obstruction in all patients with axial and multiplanar reconstructed images. The SVC showed total obstruction in five patients and partial obstruction in two patients. The most common experienced collateral vessels were azygos vein (6), intercostal veins (6), mediastinal veins (6), paravertebral veins (5), hemiazygos vein (5), thoracoepigastric vein (5), internal mammary vein (5), thoracoacromioclavicular venous plexus (5), and anterior chest wall veins (5). While one case showed the portal-systemic shunt, V. cordis media and sinus coronarius with phrenic veins were enlarged in two cases, and the left adrenal vein was enlarged in a patient. In one case, the azygos vein with reversed

  5. Abnormal left superior temporal gyrus volumes in children and adolescents with bipolar disorder: a magnetic resonance imaging study.

    Science.gov (United States)

    Chen, Hua Hsua; Nicoletti, Mark A; Hatch, John P; Sassi, Roberto B; Axelson, David; Brambilla, Paolo; Monkul, E Serap; Keshavan, Matcheri S; Ryan, Neal D; Birmaher, Boris; Soares, Jair C

    2004-06-03

    Abnormalities in left superior temporal gyrus (STG) have been reported in adult bipolar patients. However, it is not known whether such abnormalities are already present early in the course of this illness. Magnetic resonance imaging (MRI) morphometric analysis of STG was performed in 16 DSM-IV children and adolescents with bipolar disorder (mean age+/-SD 15.5+/-3.4 years) and 21 healthy controls (mean age+/-SD 16.9+/-3.8 years). Subjects underwent a 3D spoiled gradient recalled acquisition MRI examination. Using analysis of covariance with age, gender and intra-cranial brain volume as covariates, we found significantly smaller left total STG volumes in bipolar patients (12.5+/-1.5 cm(3)) compared with healthy controls (13.6+/-2.5 cm(3)) (F=4.45, d.f.=1, 32, P=0.04). This difference was accounted for by significantly smaller left and right STG white matter volumes in bipolar patients. Decreased white matter connections may be the core of abnormalities in STG, which is an important region for speech, language and communication, and could possibly underlie neurocognitive deficits present in bipolar patients.

  6. Imaging with 124I in differentiated thyroid carcinoma: is PET/MRI superior to PET/CT?

    International Nuclear Information System (INIS)

    Binse, I.; Poeppel, T.D.; Ruhlmann, M.; Gomez, B.; Bockisch, A.; Rosenbaum-Krumme, S.J.; Umutlu, L.

    2016-01-01

    The aim of this study was to compare integrated PET/CT and PET/MRI for their usefulness in detecting and categorizing cervical iodine-positive lesions in patients with differentiated thyroid cancer using 124 I as tracer. The study group comprised 65 patients at high risk of iodine-positive metastasis who underwent PET/CT (low-dose CT scan, PET acquisition time 2 min; PET/CT 2 ) followed by PET/MRI of the neck 24 h after 124 I administration. PET images from both modalities were analysed for the numbers of tracer-positive lesions. Two different acquisition times were used for the comparisons, one matching the PET/CT 2 acquisition time (2 min, PET/MRI 2 ) and the other covering the whole MRI scan time (30 min, PET/MRI 30 ). Iodine-positive lesions were categorized as metastasis, thyroid remnant or inconclusive according to their location on the PET/CT images. Morphological information provided by MRI was considered for evaluation of lesions on PET/MRI and for volume information. PET/MRI 2 detected significantly more iodine-positive metastases and thyroid remnants than PET/CT 2 (72 vs. 60, p = 0.002, and 100 vs. 80, p = 0.001, respectively), but the numbers of patients with at least one tumour lesion identified were not significantly different (21/65 vs. 17/65 patients). PET/MRI 30 tended to detect more PET-positive metastases than PET/MRI 2 (88 vs. 72), but the difference was not significant (p = 0.07). Of 21 lesions classified as inconclusive on PET/CT, 5 were assigned to metastasis or thyroid remnant when evaluated by PET/MRI. Volume information was available in 34 % of iodine-positive metastases and 2 % of thyroid remnants on PET/MRI. PET/MRI of the neck was found to be superior to PET/CT in detecting iodine-positive lesions. This was attributed to the higher sensitivity of the PET component, Although helpful in some cases, we found no substantial advantage of PET/MRI over PET/CT in categorizing iodine-positive lesions as either metastasis or thyroid remnant

  7. Cone Beam CT vs. Fan Beam CT: A Comparison of Image Quality and Dose Delivered Between Two Differing CT Imaging Modalities.

    Science.gov (United States)

    Lechuga, Lawrence; Weidlich, Georg A

    2016-09-12

    A comparison of image quality and dose delivered between two differing computed tomography (CT) imaging modalities-fan beam and cone beam-was performed. A literature review of quantitative analyses for various image quality aspects such as uniformity, signal-to-noise ratio, artifact presence, spatial resolution, modulation transfer function (MTF), and low contrast resolution was generated. With these aspects quantified, cone beam computed tomography (CBCT) shows a superior spatial resolution to that of fan beam, while fan beam shows a greater ability to produce clear and anatomically correct images with better soft tissue differentiation. The results indicate that fan beam CT produces superior images to that of on-board imaging (OBI) cone beam CT systems, while providing a considerably less dose to the patient.

  8. Simulations of the x-ray imaging capabilities of the silicon drift detectors (SDD) for the LOFT wide-field monitor

    DEFF Research Database (Denmark)

    Evangelista, Y.; Campana, R.; Del Monte, E.

    2012-01-01

    Detector (LAD), carrying an unprecedented effective area of 10 m^2, is complemented by a coded-mask Wide Field Monitor, in charge of monitoring a large fraction of the sky potentially accessible to the LAD, to provide the history and context for the sources observed by LAD and to trigger its observations...... on their most interesting and extreme states. In this paper we present detailed simulations of the imaging capabilities of the Silicon Drift Detectors developed for the LOFT Wide Field Monitor detection plane. The simulations explore a large parameter space for both the detector design and the environmental...

  9. Burlington Northern Taconite Transshipment Facility, Duluth-Superior Harbor, Superior Wisconsin. Environmental Assessment Report.

    Science.gov (United States)

    1975-03-01

    the Federal Government declared the Duluth- Superior area to be economically depressed . The reason given was the "consistant and chronic unemployment...include dogwood, sumac, arrowwood, blueberry, highbush cranberry , elderberry, wild grape, buttonbrush, snowberry and partridgeberry. Aquatic and...water for the proposed greenbelt areas and as dust sup- pression spray. 10.003 The depressed economy of the Duluth-Superior area would benefit by the

  10. Multiple Image Radiography With Diffraction Enhanced Imaging For Breast Specimen

    International Nuclear Information System (INIS)

    Oltulu, Oral; Zhong Zhong; Hasnah, Moumen; Chapman, Dean

    2007-01-01

    Biological samples are of great interest for many imaging techniques. The samples usually contain small structures and weak absorption properties. The combinations of weak signals with overlying structures make feature recognition difficult in many cases. In the x-ray regime, a relatively new imaging technique Diffraction Enhanced Imaging (DEI) has superior tissue contrast over conventional radiography and is proven to be very sensitive method. Multiple images taken by DEI are called Multiple Image Radiography (MIR). The purpose of this study is to validate the potential application of the method and to show that MIR-DEI method may give more information about the sample

  11. Superior oblique luxation and trochlear luxation as new concepts in superior oblique muscle weakening surgery

    NARCIS (Netherlands)

    Mombaerts, I.; Koornneef, L.; Everhard-Halm, Y. S.; Hughes, D. S.; Maillette de Buy Wenniger-Prick, L. J.

    1995-01-01

    We used superior oblique luxation and trochlear luxation as new surgical procedures to treat acquired Brown's syndrome and superior oblique muscle overaction. We studied nine patients (11 eyes) who underwent trochlear surgery between 1988 and 1993. Four patients had acquired Brown's syndrome and

  12. Multifunctional nanoparticle-EpCAM aptamer bioconjugates: a paradigm for targeted drug delivery and imaging in cancer therapy.

    Science.gov (United States)

    Das, Manasi; Duan, Wei; Sahoo, Sanjeeb K

    2015-02-01

    The promising proposition of multifunctional nanoparticles for cancer diagnostics and therapeutics has inspired the development of theranostic approach for improved cancer therapy. Moreover, active targeting of drug carrier to specific target site is crucial for providing efficient delivery of therapeutics and imaging agents. In this regard, the present study investigates the theranostic capabilities of nutlin-3a loaded poly (lactide-co-glycolide) nanoparticles, functionalized with a targeting ligand (EpCAM aptamer) and an imaging agent (quantum dots) for cancer therapy and bioimaging. A wide spectrum of in vitro analysis (cellular uptake study, cytotoxicity assay, cell cycle and apoptosis analysis, apoptosis associated proteins study) revealed superior therapeutic potentiality of targeted NPs over other formulations in EpCAM expressing cells. Moreover, our nanotheranostic system served as a superlative bio-imaging modality both in 2D monolayer culture and tumor spheroid model. Our result suggests that, these aptamer-guided multifunctional NPs may act as indispensable nanotheranostic approach toward cancer therapy. This study investigated the theranostic capabilities of nutlin-3a loaded poly (lactide-co-glycolide) nanoparticles functionalized with a targeting ligand (EpCAM aptamer) and an imaging agent (quantum dots) for cancer therapy and bioimaging. It was concluded that the studied multifunctional targeted nanoparticle may become a viable and efficient approach in cancer therapy. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Automated radial basis function neural network based image classification system for diabetic retinopathy detection in retinal images

    Science.gov (United States)

    Anitha, J.; Vijila, C. Kezi Selva; Hemanth, D. Jude

    2010-02-01

    Diabetic retinopathy (DR) is a chronic eye disease for which early detection is highly essential to avoid any fatal results. Image processing of retinal images emerge as a feasible tool for this early diagnosis. Digital image processing techniques involve image classification which is a significant technique to detect the abnormality in the eye. Various automated classification systems have been developed in the recent years but most of them lack high classification accuracy. Artificial neural networks are the widely preferred artificial intelligence technique since it yields superior results in terms of classification accuracy. In this work, Radial Basis function (RBF) neural network based bi-level classification system is proposed to differentiate abnormal DR Images and normal retinal images. The results are analyzed in terms of classification accuracy, sensitivity and specificity. A comparative analysis is performed with the results of the probabilistic classifier namely Bayesian classifier to show the superior nature of neural classifier. Experimental results show promising results for the neural classifier in terms of the performance measures.

  14. P and e identification capabilities CAPRICE

    Energy Technology Data Exchange (ETDEWEB)

    Basini, G. [INFN, Laboratori Nazionali di Frascati, Rome (Italy); Codino, A.; Grimani, C. [Perugia Univ. (Italy)]|[INFN, Perugia (Italy); De Pascale, M.P. [Rome Univ. `Tor Vergata` (Italy)]|[INFN, Rome (Italy); Hof, M. [Siegen Univ. (Germany). Fachbereich Physik; Golden, R.L. [New Mexico State Univ., Las Cruces, NM (United States). Particle Astrophysics Lab.; Brancaccio, F.; Bocciolini, M. [Florence Univ. (Italy)]|[INFN, Florence (Italy); Barbiellini, G.; Boezio, M. [Trieste Univ. (Italy)]|[INFN, Trieste (Italy)

    1995-09-01

    The cosmic antiparticle ring imaging Cherenkov experiment (CAPRICE) flew on a stratospheric balloon 8-9 August 1994 over northern Canada and collected data for more than 21 hours with less than 5 g/cm{sup 2} of residual atmosphere. The instrument includes a solid radiator RICH detector and an electromagnetic calorimeter for particle identification in the magnetic spectrometer. Preliminary antiproton and positron identification capabilities are presented.

  15. Magnetic resonance imaging of the fetal brain.

    Science.gov (United States)

    Tee, L Mf; Kan, E Yl; Cheung, J Cy; Leung, W C

    2016-06-01

    This review covers the recent literature on fetal brain magnetic resonance imaging, with emphasis on techniques, advances, common indications, and safety. We conducted a search of MEDLINE for articles published after 2010. The search terms used were "(fetal OR foetal OR fetus OR foetus) AND (MR OR MRI OR [magnetic resonance]) AND (brain OR cerebral)". Consensus statements from major authorities were also included. As a result, 44 relevant articles were included and formed the basis of this review. One major challenge is fetal motion that is largely overcome by ultra-fast sequences. Currently, single-shot fast spin-echo T2-weighted imaging remains the mainstay for motion resistance and anatomical delineation. Recently, a snap-shot inversion recovery sequence has enabled robust T1-weighted images to be obtained, which is previously a challenge for standard gradient-echo acquisitions. Fetal diffusion-weighted imaging, diffusion tensor imaging, and magnetic resonance spectroscopy are also being developed. With multiplanar capabilities, superior contrast resolution and field of view, magnetic resonance imaging does not have the limitations of sonography, and can provide additional important information. Common indications include ventriculomegaly, callosum and posterior fossa abnormalities, and twin complications. There are safety concerns about magnetic resonance-induced heating and acoustic damage but current literature showed no conclusive evidence of deleterious fetal effects. The American College of Radiology guideline states that pregnant patients can be accepted to undergo magnetic resonance imaging at any stage of pregnancy if risk-benefit ratio to patients warrants that the study be performed. Magnetic resonance imaging of the fetal brain is a safe and powerful adjunct to sonography in prenatal diagnosis. It can provide additional information that aids clinical management, prognostication, and counselling.

  16. Alternate superior Julia sets

    International Nuclear Information System (INIS)

    Yadav, Anju; Rani, Mamta

    2015-01-01

    Alternate Julia sets have been studied in Picard iterative procedures. The purpose of this paper is to study the quadratic and cubic maps using superior iterates to obtain Julia sets with different alternate structures. Analytically, graphically and computationally it has been shown that alternate superior Julia sets can be connected, disconnected and totally disconnected, and also fattier than the corresponding alternate Julia sets. A few examples have been studied by applying different type of alternate structures

  17. Incompatible Images

    DEFF Research Database (Denmark)

    Sassene, Michel J.; Hertzum, Morten

    2008-01-01

    is, however, based on a taken-for-granted image of asthmatics as, per se, striving to be symptom-free. This image is incompatible with interviewed asthmatics' day-to-day performances of their asthma, and renders invisible (a) that their asthma performances emphasize an economy of good passages...... and of feeling capable, (b) that they achieve the objective of feeling capable in quite different ways, and (c) that feeling capable does not per se equal being symptom-free all the time. To attain long-term use of self-management systems and other patient-centred e-health systems, such systems must acknowledge...

  18. EXPLORER: Changing the molecular imaging paradigm with total-body PET/CT (Conference Presentation)

    Science.gov (United States)

    Cherry, Simon R.; Badawi, Ramsey D.; Jones, Terry

    2016-04-01

    Positron emission tomography (PET) is the highest sensitivity technique for human whole-body imaging studies. However, current clinical PET scanners do not make full use of the available signal, as they only permit imaging of a 15-25 cm segment of the body at one time. Given the limited sensitive region, whole-body imaging with clinical PET scanners requires relatively long scan times and subjects the patient to higher than necessary radiation doses. The EXPLORER initiative aims to build a 2-meter axial length PET scanner to allow imaging the entire subject at once, capturing nearly the entire available PET signal. EXPLORER will acquire data with ~40-fold greater sensitivity leading to a six-fold increase in reconstructed signal-to-noise ratio for imaging the total body. Alternatively, total-body images with the EXPLORER scanner will be able to be acquired in ~30 seconds or with ~0.15 mSv injected dose, while maintaining current PET image quality. The superior sensitivity will open many new avenues for biomedical research. Specifically for cancer applications, high sensitivity PET will enable detection of smaller lesions. Additionally, greater sensitivity will allow imaging out to 10 half-lives of positron emitting radiotracers. This will enable 1) metabolic ultra-staging with FDG by extending the uptake and clearance time to 3-5 hours to significantly improve contrast and 2) improved kinetic imaging with short-lived radioisotopes such as C-11, crucial for drug development studies. Frequent imaging studies of the same subject to study disease progression or to track response to therapy will be possible with the low dose capabilities of the EXPLORER scanner. The low dose capabilities will also open up new imaging possibilities in pediatrics and adolescents to better study developmental disorders. This talk will review the basis for developing total-body PET, potential applications, and review progress to date in developing EXPLORER, the first total-body PET scanner.

  19. Skeletal imaging composition

    International Nuclear Information System (INIS)

    Vanduzee, B.F.; Degenhardt, C.R.

    1983-01-01

    This invention is based on the discovery that the adjustment of pH, within a particular range, during the process of manufacturing lyophilized diphosphonate-containing skeletal imaging kits yields a kit which produces a technetium skeletal imaging agent with superior imaging properties. This increased performance is manifested through faster blood clearance and higher skeletal uptake of the technetium imaging agent. The process for producing a dry-powder imaging kit comprises the steps of: preparing a solution of a diphosphonate carrier, stannous reductant, and a stabilizer in water; adjusting the pH to between 5.5 and 6.5; and lyophilizing the solution

  20. Electroactive and High Dielectric Folic Acid/PVDF Composite Film Rooted Simplistic Organic Photovoltaic Self-Charging Energy Storage Cell with Superior Energy Density and Storage Capability.

    Science.gov (United States)

    Roy, Swagata; Thakur, Pradip; Hoque, Nur Amin; Bagchi, Biswajoy; Sepay, Nayim; Khatun, Farha; Kool, Arpan; Das, Sukhen

    2017-07-19

    Herein we report a simplistic prototype approach to develop an organic photovoltaic self-charging energy storage cell (OPSESC) rooted with biopolymer folic acid (FA) modified high dielectric and electroactive β crystal enriched poly(vinylidene fluoride) (PVDF) composite (PFA) thin film. Comprehensive and exhaustive characterizations of the synthesized PFA composite films validate the proper formation of β-polymorphs in PVDF. Significant improvements of both β-phase crystallization (F(β) ≈ 71.4%) and dielectric constant (ε ≈ 218 at 20 Hz for PFA of 7.5 mass %) are the twosome realizations of our current study. Enhancement of β-phase nucleation in the composites can be thought as a contribution of the strong interaction of the FA particles with the PVDF chains. Maxwell-Wagner-Sillars (MWS) interfacial polarization approves the establishment of thermally stable high dielectric values measured over a wide temperature spectrum. The optimized high dielectric and electroactive films are further employed as an active energy storage material in designing our device named as OPSESC. Self-charging under visible light irradiation without an external biasing electrical field and simultaneous remarkable self-storage of photogenerated electrical energy are the two foremost aptitudes and the spotlight of our present investigation. Our as fabricated device delivers an impressively high energy density of 7.84 mWh/g and an excellent specific capacitance of 61 F/g which is superior relative to the other photon induced two electrode organic self-charging energy storage devices reported so far. Our device also proves the realistic utility with good recycling capability by facilitating commercially available light emitting diode.

  1. Anatomy of right superior septal artery demonstrated on the coronary CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Takeguchi, Takaya (Mitsui Memorial Hospital, Department of Diagnostic Radiology, Tokyo (Japan); Tokyo Medical and Dental University, Department of Diagnostic Radiology, Tokyo (Japan)); Ibukuro, Kenji; Fukuda, Hozumi; Tobe, Kimiko; Abe, Shoko (Mitsui Memorial Hospital, Department of Diagnostic Radiology, Tokyo (Japan)), Email: kj-ibkr@qd6.so-net.ne.jp

    2012-02-15

    Background. A coronary CT scan allows for non-invasive visualization of the anatomy of a coronary artery in three dimensions compared to the two dimensions afforded by conventional angiography. The septal artery, the main blood source of the interventricular septum, is usually derived from the left anterior descending artery; however, it is occasionally derived from the right coronary artery. Purpose. To analyze the prevalence, origin, diameter, and length of the right superior septal artery (RSSA) demonstrated on a coronary CT scan. Material and Methods. The right superior septal artery was retrospectively reviewed on the reconstructed axial scan images (0.5-mm thickness, 0.25-mm interval) in 1290 consecutive patients who underwent coronary CT scans. All patients were scanned on a 320-row CT scanner. The images were transferred to a workstation to trace the vessel to analyze the origin, diameter, and length. We also compared the length of the RSSA between patients with and without coronary artery stenosis. Results. The RSSA was identified in 51 (3.9%) of 1290 patients. The origin was the proximal portion of the right coronary artery (n = 40) or the right sinus of Valsalva (n 11). The artery co-existed with the conus artery in 15 (29%) of 51 patients. The length was 16-62 mm (mean 31.2 mm +- 10.5), and the diameter was 0.8-2.0 mm (mean 1.3 mm +- 0.2). Longer RSSAs tended to be demonstrated in the patients with coronary artery stenosis rather than with normal coronary arteries (P < 0.05). Conclusion. The right superior septal artery and its anatomical variant could be analyzed with a coronary CT scan. The ability to demonstrate this artery on the coronary CT scan was the same as with coronary angiography. The recognition of this vessel is useful for physicians managing with the diagnosis and treatment of the coronary artery disease

  2. Detection of bridging veins draining into superior sagittal sinus by using susceptibility weighted imaging and three dimensional contrast enhancement MR venography

    International Nuclear Information System (INIS)

    Xia Chunhua; Chen Dan; Chen Bing; Wang Yajun; Xia Shiyong; Liu Wenli; Zhang Zhenhua; Wang Hui; Wu Lingqiao

    2011-01-01

    Objective: To use the superior sagittal sinus (SSS) as an example to identify anatomical features of the bridging veins (BVs) draining into the SSS in both susceptibility weighted imaging (SWI) and three dimensional contrast enhancement MR venography (3D-CEMRV) images. Methods: A total of 20 healthy volunteers (40 sides) were examined in this study. The venograms of each patient was obtained from SWI (40 sides out of 20 volunteers) and 3D-CE MRV (40 sides out of 20 volunteers). The data were analyzed by t test. Results: According to their draining location with respect to the SSS, bridging veins were divided into two groups. Between the anterior group and the posterior group were two segments of the SSS into which few bridging veins drained. Observed by 3D-CE MRV and SWI, the average numbers of the anterior group were 1.9±0.6 and 3.2±0.8, respectively, and the average diameters of the anterior group were (3.4±1.1) and (2.1±0.5) mm, respectively. These differences between 3D-CE MRV and SWI images were significant (t=11.23, 9.76, P<0.01). Observed by 3D-CE MRV and SWI, the average numbers of the posterior group were 3.5±1.2 and 5.9±1.1, respectively, and the average diameters of the posterior group were (3.7±0.9) and (2.9±0.7) mm, respectively. The differences between the two technique were significant as well (t=11.51, 8.47, P<0.01). Conclusion: The dural entrance of BVs into the SSS can be identified in both SWI and 3D-CE MRV images. The preoperative venogram by using 3D-CE MRV and SWI is useful to design a individual-tailored surgical approach for the preservation of BVs draining into SSS. SWI outweighs 3D-CE MRV in identifying anatomical features of the dural entrance of BVs into the SSS. (authors)

  3. Refueling machine with relative positioning capability

    International Nuclear Information System (INIS)

    Challberg, R.C.; Jones, C.R.

    1998-01-01

    A refueling machine is disclosed having relative positioning capability for refueling a nuclear reactor. The refueling machine includes a pair of articulated arms mounted on a refueling bridge. Each arm supports a respective telescoping mast. Each telescoping mast is designed to flex laterally in response to application of a lateral thrust on the end of the mast. A pendant mounted on the end of the mast carries an air-actuated grapple, television cameras, ultrasonic transducers and waterjet thrusters. The ultrasonic transducers are used to detect the gross position of the grapple relative to the bail of a nuclear fuel assembly in the fuel core. The television cameras acquire an image of the bail which is compared to a pre-stored image in computer memory. The pendant can be rotated until the television image and the pre-stored image match within a predetermined tolerance. Similarly, the waterjet thrusters can be used to apply lateral thrust to the end of the flexible mast to place the grapple in a fine position relative to the bail as a function of the discrepancy between the television and pre-stored images. 11 figs

  4. Refueling machine with relative positioning capability

    Science.gov (United States)

    Challberg, R.C.; Jones, C.R.

    1998-12-15

    A refueling machine is disclosed having relative positioning capability for refueling a nuclear reactor. The refueling machine includes a pair of articulated arms mounted on a refueling bridge. Each arm supports a respective telescoping mast. Each telescoping mast is designed to flex laterally in response to application of a lateral thrust on the end of the mast. A pendant mounted on the end of the mast carries an air-actuated grapple, television cameras, ultrasonic transducers and waterjet thrusters. The ultrasonic transducers are used to detect the gross position of the grapple relative to the bail of a nuclear fuel assembly in the fuel core. The television cameras acquire an image of the bail which is compared to a pre-stored image in computer memory. The pendant can be rotated until the television image and the pre-stored image match within a predetermined tolerance. Similarly, the waterjet thrusters can be used to apply lateral thrust to the end of the flexible mast to place the grapple in a fine position relative to the bail as a function of the discrepancy between the television and pre-stored images. 11 figs.

  5. Cumulative phase delay imaging for contrast-enhanced ultrasound tomography

    International Nuclear Information System (INIS)

    Demi, Libertario; Van Sloun, Ruud J G; Wijkstra, Hessel; Mischi, Massimo

    2015-01-01

    Standard dynamic-contrast enhanced ultrasound (DCE-US) imaging detects and estimates ultrasound-contrast-agent (UCA) concentration based on the amplitude of the nonlinear (harmonic) components generated during ultrasound (US) propagation through UCAs. However, harmonic components generation is not specific to UCAs, as it also occurs for US propagating through tissue. Moreover, nonlinear artifacts affect standard DCE-US imaging, causing contrast to tissue ratio reduction, and resulting in possible misclassification of tissue and misinterpretation of UCA concentration. Furthermore, no contrast-specific modality exists for DCE-US tomography; in particular speed-of-sound changes due to UCAs are well within those caused by different tissue types. Recently, a new marker for UCAs has been introduced. A cumulative phase delay (CPD) between the second harmonic and fundamental component is in fact observable for US propagating through UCAs, and is absent in tissue. In this paper, tomographic US images based on CPD are for the first time presented and compared to speed-of-sound US tomography. Results show the applicability of this marker for contrast specific US imaging, with cumulative phase delay imaging (CPDI) showing superior capabilities in detecting and localizing UCA, as compared to speed-of-sound US tomography. Cavities (filled with UCA) which were down to 1 mm in diameter were clearly detectable. Moreover, CPDI is free of the above mentioned nonlinear artifacts. These results open important possibilities to DCE-US tomography, with potential applications to breast imaging for cancer localization. (fast track communication)

  6. Concomitant Persistent Left Superior Vena Cava and Horseshoe Kidney

    Directory of Open Access Journals (Sweden)

    Faraz Jaffer

    2015-01-01

    Full Text Available Persistent left superior vena cava (PLSVC and horseshoe kidney (HSK are common congenital abnormalities; however presence of both in the same person is extremely rare. A patient with hepatitis C cirrhosis awaiting transplant presented with worsening liver dysfunction, diagnosed with acute renal failure secondary to hepatorenal syndrome, and required X-ray fluoroscopy guided tunneled venous catheter placement for hemodialysis. Review of imaging studies demonstrated coexistence of PLSVC and HSK. PLSVC in adulthood is usually incidental with the most common drainage pattern being without physiologic dysfunction. Isolated horseshoe kidney is still the most common of renal fusion anomalies; however etiology of coexistent PLSVC remains unknown.

  7. Subnuclear foci quantification using high-throughput 3D image cytometry

    Science.gov (United States)

    Wadduwage, Dushan N.; Parrish, Marcus; Choi, Heejin; Engelward, Bevin P.; Matsudaira, Paul; So, Peter T. C.

    2015-07-01

    Ionising radiation causes various types of DNA damages including double strand breaks (DSBs). DSBs are often recognized by DNA repair protein ATM which forms gamma-H2AX foci at the site of the DSBs that can be visualized using immunohistochemistry. However most of such experiments are of low throughput in terms of imaging and image analysis techniques. Most of the studies still use manual counting or classification. Hence they are limited to counting a low number of foci per cell (5 foci per nucleus) as the quantification process is extremely labour intensive. Therefore we have developed a high throughput instrumentation and computational pipeline specialized for gamma-H2AX foci quantification. A population of cells with highly clustered foci inside nuclei were imaged, in 3D with submicron resolution, using an in-house developed high throughput image cytometer. Imaging speeds as high as 800 cells/second in 3D were achieved by using HiLo wide-field depth resolved imaging and a remote z-scanning technique. Then the number of foci per cell nucleus were quantified using a 3D extended maxima transform based algorithm. Our results suggests that while most of the other 2D imaging and manual quantification studies can count only up to about 5 foci per nucleus our method is capable of counting more than 100. Moreover we show that 3D analysis is significantly superior compared to the 2D techniques.

  8. ImageX: new and improved image explorer for astronomical images and beyond

    Science.gov (United States)

    Hayashi, Soichi; Gopu, Arvind; Kotulla, Ralf; Young, Michael D.

    2016-08-01

    The One Degree Imager - Portal, Pipeline, and Archive (ODI-PPA) has included the Image Explorer interactive image visualization tool since it went operational. Portal users were able to quickly open up several ODI images within any HTML5 capable web browser, adjust the scaling, apply color maps, and perform other basic image visualization steps typically done on a desktop client like DS9. However, the original design of the Image Explorer required lossless PNG tiles to be generated and stored for all raw and reduced ODI images thereby taking up tens of TB of spinning disk space even though a small fraction of those images were being accessed by portal users at any given time. It also caused significant overhead on the portal web application and the Apache webserver used by ODI-PPA. We found it hard to merge in improvements made to a similar deployment in another project's portal. To address these concerns, we re-architected Image Explorer from scratch and came up with ImageX, a set of microservices that are part of the IU Trident project software suite, with rapid interactive visualization capabilities useful for ODI data and beyond. We generate a full resolution JPEG image for each raw and reduced ODI FITS image before producing a JPG tileset, one that can be rendered using the ImageX frontend code at various locations as appropriate within a web portal (for example: on tabular image listings, views allowing quick perusal of a set of thumbnails or other image sifting activities). The new design has decreased spinning disk requirements, uses AngularJS for the client side Model/View code (instead of depending on backend PHP Model/View/Controller code previously used), OpenSeaDragon to render the tile images, and uses nginx and a lightweight NodeJS application to serve tile images thereby significantly decreasing the Time To First Byte latency by a few orders of magnitude. We plan to extend ImageX for non-FITS images including electron microscopy and radiology scan

  9. Enhancing forensic science with spectroscopic imaging

    Science.gov (United States)

    Ricci, Camilla; Kazarian, Sergei G.

    2006-09-01

    This presentation outlines the research we are developing in the area of Fourier Transform Infrared (FTIR) spectroscopic imaging with the focus on materials of forensic interest. FTIR spectroscopic imaging has recently emerged as a powerful tool for characterisation of heterogeneous materials. FTIR imaging relies on the ability of the military-developed infrared array detector to simultaneously measure spectra from thousands of different locations in a sample. Recently developed application of FTIR imaging using an ATR (Attenuated Total Reflection) mode has demonstrated the ability of this method to achieve spatial resolution beyond the diffraction limit of infrared light in air. Chemical visualisation with enhanced spatial resolution in micro-ATR mode broadens the range of materials studied with FTIR imaging with applications to pharmaceutical formulations or biological samples. Macro-ATR imaging has also been developed for chemical imaging analysis of large surface area samples and was applied to analyse the surface of human skin (e.g. finger), counterfeit tablets, textile materials (clothing), etc. This approach demonstrated the ability of this imaging method to detect trace materials attached to the surface of the skin. This may also prove as a valuable tool in detection of traces of explosives left or trapped on the surfaces of different materials. This FTIR imaging method is substantially superior to many of the other imaging methods due to inherent chemical specificity of infrared spectroscopy and fast acquisition times of this technique. Our preliminary data demonstrated that this methodology will provide the means to non-destructive detection method that could relate evidence to its source. This will be important in a wider crime prevention programme. In summary, intrinsic chemical specificity and enhanced visualising capability of FTIR spectroscopic imaging open a window of opportunities for counter-terrorism and crime-fighting, with applications ranging

  10. Does the Primary Imaging Modality-Computed Tomography or Magnetic Resonance Imaging-Influence Stroke Physicians' Certainty on Whether or Not to Give Thrombolysis to Randomized Acute Stroke Patients?

    DEFF Research Database (Denmark)

    Hansen, Christine Krarup; Christensen, Anders; Rodgers, Helen

    2018-01-01

    BACKGROUND: Door-to-needle time of 20 minutes to stroke patients with intravenous tissue plasminogen activator (iv-tPA) is feasible when computed tomography (CT) is used as first-line of brain imaging. Magnetic resonance imaging (MRI)-based assessment is more time-consuming but superior in detect......BACKGROUND: Door-to-needle time of 20 minutes to stroke patients with intravenous tissue plasminogen activator (iv-tPA) is feasible when computed tomography (CT) is used as first-line of brain imaging. Magnetic resonance imaging (MRI)-based assessment is more time-consuming but superior...

  11. Superior Cycle Stability Performance of Quasi-Cuboidal CoV2O6 Microstructures as Electrode Material for Supercapacitors.

    Science.gov (United States)

    Wang, Yucheng; Chai, Hui; Dong, Hong; Xu, Jiayu; Jia, Dianzeng; Zhou, Wanyong

    2016-10-12

    In this study, a rapid, facile, and environment-friendly microwave-assisted method followed by annealing for synthesizing the quasi-cuboidal CoV 2 O 6 is developed. The as-prepared samples manifest high supercapacitor properties with a specific capacitance of 223 F g -1 , good rate capability, and superior cycle stability, retaining 123.3% capacitance when the number of cycles reaches 15,000 after determined by electrochemical tests. More importantly, the quasi-cuboidal CoV 2 O 6 for the first time is introduced into the supercapacitor as a kind of electrode material. The superior electrochemical performance of the quasi-cuboidal CoV 2 O 6 will render the metal vanadium oxides as new and attractive active material for promising application in supercapacitors.

  12. Renewable and superior thermal-resistant cellulose-based composite nonwoven as lithium-ion battery separator.

    Science.gov (United States)

    Zhang, Jianjun; Liu, Zhihong; Kong, Qingshan; Zhang, Chuanjian; Pang, Shuping; Yue, Liping; Wang, Xuejiang; Yao, Jianhua; Cui, Guanglei

    2013-01-01

    A renewable and superior thermal-resistant cellulose-based composite nonwoven was explored as lithium-ion battery separator via an electrospinning technique followed by a dip-coating process. It was demonstrated that such nanofibrous composite nonwoven possessed good electrolyte wettability, excellent heat tolerance, and high ionic conductivity. The cells using the composite separator displayed better rate capability and enhanced capacity retention, when compared to those of commercialized polypropylene separator under the same conditions. These fascinating characteristics would endow this renewable composite nonwoven a promising separator for high-power lithium-ion battery.

  13. Technobabble: Photoshop 6 Converges Web, Print Photograph-Editing Capabilities.

    Science.gov (United States)

    Communication: Journalism Education Today, 2001

    2001-01-01

    Discusses the newly-released Adobe Photoshop 6, and its use in student publications. Notes its refined text-handling capabilities, a more user-friendly interface, integrated vector functions, easier preparation of Web images, and new and more powerful layer functions. (SR)

  14. Spatial resolution measurements of the advanced radiographic capability x-ray imaging system at energies relevant to Compton radiography

    Energy Technology Data Exchange (ETDEWEB)

    Hall, G. N., E-mail: hall98@llnl.gov; Izumi, N.; Landen, O. L.; Tommasini, R.; Holder, J. P.; Hargrove, D.; Bradley, D. K.; Lumbard, A.; Cruz, J. G.; Piston, K.; Bell, P. M.; Carpenter, A. C.; Palmer, N. E.; Felker, B.; Rekow, V.; Allen, F. V. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550 (United States); Lee, J. J.; Romano, E. [National Security Technologies LLC, 161 S Vasco Rd., Livermore, California 94551 (United States)

    2016-11-15

    Compton radiography provides a means to measure the integrity, ρR and symmetry of the DT fuel in an inertial confinement fusion implosion near peak compression. Upcoming experiments at the National Ignition Facility will use the ARC (Advanced Radiography Capability) laser to drive backlighter sources for Compton radiography experiments and will use the newly commissioned AXIS (ARC X-ray Imaging System) instrument as the detector. AXIS uses a dual-MCP (micro-channel plate) to provide gating and high DQE at the 40–200 keV x-ray range required for Compton radiography, but introduces many effects that contribute to the spatial resolution. Experiments were performed at energies relevant to Compton radiography to begin characterization of the spatial resolution of the AXIS diagnostic.

  15. MR imaging of the brain in neurofibromatosis

    International Nuclear Information System (INIS)

    Kuhn, J.P.; Cohen, M.L.; Duffner, P.K.; Seidel, F.; Harwood-Nash, D.

    1986-01-01

    Fifteen children and young adults with neurofibromatosis underwent CT and MR imaging (0.5-T superconducting magnet). Seven had optic gliomas and five had other intracranial neoplasms. Before thin-section MR imaging became available, CT was superior for demonstrating the optic nerves, although MR imaging better delineated tumor spread to the optic chiasm and tract. MR imaging was superior for demonstrating other gliomatous lesions associated with neurofibromatosis. Most lesions had long T1 and T2 values and were best seen on T2-weighted images. MR imaging revealed small areas of increased signal intensity on T2-weighted images in nearly half the patients. These lesions were not apparent on CT and were usually located in the globus pallidus, but were seen in many areas of the brain, commonly in the white matter, and in the brain steam and the cerebellar peduncles. Their exact etiology is unknown. Their imaging characteristics are somewhat different from those of gray matter. They may represent hamartomas or areas of glial scarring. Differentiation from a small glioma is presently not possible on a single examination

  16. Superior Hiking Trail

    Data.gov (United States)

    Minnesota Department of Natural Resources — Superior Hiking Trail main trail, spurs, and camp spurs for completed trail throughout Cook, Lake, St. Louis and Carlton counties. These data were collected with...

  17. Multifunctional nanomaterials for advanced molecular imaging and cancer therapy

    Science.gov (United States)

    Subramaniam, Prasad

    Nanotechnology offers tremendous potential for use in biomedical applications, including cancer and stem cell imaging, disease diagnosis and drug delivery. The development of nanosystems has aided in understanding the molecular mechanisms of many diseases and permitted the controlled nanoscale manipulation of biological phenomena. In recent years, many studies have focused on the use of several kinds of nanomaterials for cancer and stem cell imaging and also for the delivery of anticancer therapeutics to tumor cells. However, the proper diagnosis and treatment of aggressive tumors such as brain and breast cancer requires highly sensitive diagnostic agents, in addition to the ability to deliver multiple therapeutics using a single platform to the target cells. Addressing these challenges, novel multifunctional nanomaterial-based platforms that incorporate multiple therapeutic and diagnostic agents, with superior molecular imaging and targeting capabilities, has been presented in this work. The initial part of this work presents the development of novel nanomaterials with superior optical properties for efficiently delivering soluble cues such as small interfering RNA (siRNA) into brain cancer cells with minimal toxicity. Specifically, this section details the development of non-toxic quantums dots for the imaging and delivery of siRNA into brain cancer and mesenchymal stem cells, with the hope of using these quantum dots as multiplexed imaging and delivery vehicles. The use of these quantum dots could overcome the toxicity issues associated with the use of conventional quantum dots, enabled the imaging of brain cancer and stem cells with high efficiency and allowed for the delivery of siRNA to knockdown the target oncogene in brain cancer cells. The latter part of this thesis details the development of nanomaterial-based drug delivery platforms for the co-delivery of multiple anticancer drugs to brain tumor cells. In particular, this part of the thesis focuses on

  18. Imaging with {sup 124}I in differentiated thyroid carcinoma: is PET/MRI superior to PET/CT?

    Energy Technology Data Exchange (ETDEWEB)

    Binse, I.; Poeppel, T.D.; Ruhlmann, M.; Gomez, B.; Bockisch, A.; Rosenbaum-Krumme, S.J. [University of Duisburg-Essen, Medical Faculty, Department of Nuclear Medicine, Essen (Germany); Umutlu, L. [University of Duisburg-Essen, Medical Faculty, Department of Radiology, Essen (Germany)

    2016-06-15

    The aim of this study was to compare integrated PET/CT and PET/MRI for their usefulness in detecting and categorizing cervical iodine-positive lesions in patients with differentiated thyroid cancer using {sup 124}I as tracer. The study group comprised 65 patients at high risk of iodine-positive metastasis who underwent PET/CT (low-dose CT scan, PET acquisition time 2 min; PET/CT{sub 2}) followed by PET/MRI of the neck 24 h after {sup 124}I administration. PET images from both modalities were analysed for the numbers of tracer-positive lesions. Two different acquisition times were used for the comparisons, one matching the PET/CT{sub 2} acquisition time (2 min, PET/MRI{sub 2}) and the other covering the whole MRI scan time (30 min, PET/MRI{sub 30}). Iodine-positive lesions were categorized as metastasis, thyroid remnant or inconclusive according to their location on the PET/CT images. Morphological information provided by MRI was considered for evaluation of lesions on PET/MRI and for volume information. PET/MRI{sub 2} detected significantly more iodine-positive metastases and thyroid remnants than PET/CT{sub 2} (72 vs. 60, p = 0.002, and 100 vs. 80, p = 0.001, respectively), but the numbers of patients with at least one tumour lesion identified were not significantly different (21/65 vs. 17/65 patients). PET/MRI{sub 30} tended to detect more PET-positive metastases than PET/MRI{sub 2} (88 vs. 72), but the difference was not significant (p = 0.07). Of 21 lesions classified as inconclusive on PET/CT, 5 were assigned to metastasis or thyroid remnant when evaluated by PET/MRI. Volume information was available in 34 % of iodine-positive metastases and 2 % of thyroid remnants on PET/MRI. PET/MRI of the neck was found to be superior to PET/CT in detecting iodine-positive lesions. This was attributed to the higher sensitivity of the PET component, Although helpful in some cases, we found no substantial advantage of PET/MRI over PET/CT in categorizing iodine

  19. Satellite instrument provides nighttime sensing capability

    Science.gov (United States)

    Showstack, Randy

    2012-12-01

    "This is not your father's low-light sensor," Steve Miller, senior research scientist and deputy director of the Cooperative Institute for Research in the Atmosphere at Colorado State University, Fort Collins, said at a 5 December news briefing at the AGU Fall Meeting. He and others at the briefing were showing off the nighttime sensing capability of the day/night band of the Visible Infrared Imaging Radiometer Suite (VIIRS) of instruments onboard the Suomi National Polar-orbiting Partnership (NPP) Earth-observing research satellite, a joint NASA and National Oceanic and Atmospheric Administration (NOAA) satellite that was launched on 28 October 2011. Noting that low-light satellite technology has been available for about 40 years, Miller said that the VIIRS day/night band "is truly a paradigm shift in the technology and capability."

  20. Structural Capability of an Organization toward Innovation Capability

    DEFF Research Database (Denmark)

    Nielsen, Susanne Balslev; Momeni, Mostafa

    2016-01-01

    The scholars in the field of strategic management have developed two major approaches for attainment of competitive advantage: an approach based on environmental opportunities, and another one based on internal capabilities of an organization. Some investigations in the last two decades have...... indicated that the advantages relying on the internal capabilities of organizations may determine the competitive position of organizations better than environmental opportunities do. Characteristics of firms shows that one of the most internal capabilities that lead the organizations to the strongest...... competitive advantage in the organizations is the innovation capability. The innovation capability is associated with other organizational capabilities, and many organizations have focused on the need to identify innovation capabilities.This research focuses on recognition of the structural aspect...

  1. Intramuscular ganglia arising from the superior tibiofibular joint: CT and MR evaluation

    International Nuclear Information System (INIS)

    Bianchi, S.; Abdelwahab, I.F.; Kenan, S.; Zwass, A.; Ricci, G.; Palomba, G.

    1995-01-01

    To evaluate the role of magnetic resonance imaging (MRI) and computed tomography (CT) in the diagnosis of intramuscular ganglia (IMG) that arise from the superior tibiofibular joint (STFJ). Our series consisted of three men and three women. Four patients were studied by MRI, one by CT only, and two by both modalities. Contrast was used in one of the two patients studied by CT. MRI was obtained in at least two orthogonal planes to demonstrate the relation of the ganglia to STFJ. The MR and CT appearance of these ganglia was basically that of a well-defined soft tissue mass with low attenuation on CT images consistent with the presence of fluid. On MR studies, they had an isointense signal on T1-weighted images and a homogenous high-intensity signal on T2-weighted images. MRI demonstrated the attachment of these ganglia to the STFJ. CT and MRI were effective, noninvasive modalities in the evaluation of IMG. The imaging features on both modalities were consistent with the presence of fluid-containing lesions that had close proximity and were attached to the STFJ. The combination of location and the fluid consistency of these lesions facilitated the diagnosis. (orig.)

  2. Magnetic resonance imaging in neurologic diseases

    International Nuclear Information System (INIS)

    Chang, Kee Hyun; Han, Man Chung; Wan, Chu Wan; Myung, Ho Jin; Choi, Kil Soo; Ahn, Chang Beom; Oh, Chang Hyun; Cho, Zang Hee

    1985-01-01

    Magnetic resonance (MR) imaging with 0.15 Tesla resistive magnet developed by Korea Advanced Institute of Science were performed in 27 patients with various neurologic diseases and compared with x-ray computed tomography (CT). The purpose of the paper is to evaluate the image quality, the diagnostic value and limitation, and the optimal pulse sequence of MR imagings with a resistive magnet. The MR images were obtained by using a variety of pulse sequence with spin echo technique including saturation recovery. T2-weighted spin echo, and/or inversion recovery with various pulse repetition (TR) and echo delay (TE) times. The MR imaging demonstrated the capability of detecting the lesions shown on CT in al cases and also detected an additional finding in one case (multiple sclerosis) which was not seen on CT. The MR imaging appeared to be more useful than CT in the evaluation of syringomyelia of spinal cord and white matter disease, while it failed to demonstrated small calcific lesion or inflammatory nodule (less than 1 cm) shown on CT and has shown somewhat poor contrast resolution in the case of meingloma. The spatial resolution of saturation recovery images was similar or superior to CT, whereas the contrast resolution of saturation recovery was inferior to CT. While the saturation recovery images have shown false negative findings in 5 patients (19%), the inversion recovery and T2-weighted spin echo have shown consistently positive findings. The inversive recovery and T2-weighted spin echo images demonstrated better contrast discrimination between normal and pathologic conditions than the saturation recovery images, but somewhat poorer spatial resolution. Authors suggest that the MR images of both the saturation recovery with 300/30 and T2-weighted spin echo with 1000/90 be used as a routine procedure and additional inversion recovery of 1300/300/30 sequence as a option if white matter disease is suspected

  3. TH-AB-209-12: Tissue Equivalent Phantom with Excised Human Tissue for Assessing Clinical Capabilities of Coherent Scatter Imaging Applications

    Energy Technology Data Exchange (ETDEWEB)

    Albanese, K; Morris, R; Spencer, J [Medical Physics Graduate Program, Duke University, Durham, NC (United States); Greenberg, J [Dept. of Electrical and Computer Engineering, Duke University, Durham, NC (United States); Kapadia, A [Carl E Ravin Advanced Imaging Laboratories, Durham, NC (United States)

    2016-06-15

    Purpose: Previously we reported the development of anthropomorphic tissue-equivalent scatter phantoms of the human breast. Here we present the first results from the scatter imaging of the tissue equivalent breast phantoms for breast cancer diagnosis. Methods: A breast phantom was designed to assess the capability of coded aperture coherent x-ray scatter imaging to classify different types of breast tissue (adipose, fibroglandular, tumor). The phantom geometry was obtained from a prone breast geometry scanned on a dedicated breast CT system. The phantom was 3D printed using the segmented DICOM breast CT data. The 3D breast phantom was filled with lard (as a surrogate for adipose tissue) and scanned in different geometries alongside excised human breast tissues (obtained from lumpectomy and mastectomy procedures). The raw data were reconstructed using a model-based reconstruction algorithm and yielded the location and form factor (i.e., momentum transfer (q) spectrum) of the materials that were imaged. The measured material form factors were then compared to the ground truth measurements acquired by x-ray diffraction (XRD) imaging. Results: Our scatter imaging system was able to define the location and composition of the various materials and tissues within the phantom. Cancerous breast tissue was detected and classified through automated spectral matching and an 86% correlation threshold. The total scan time for the sample was approximately 10 minutes and approaches workflow times for clinical use in intra-operative or other diagnostic tasks. Conclusion: This work demonstrates the first results from an anthropomorphic tissue equivalent scatter phantom to characterize a coherent scatter imaging system. The functionality of the system shows promise in applications such as intra-operative margin detection or virtual biopsy in the diagnosis of breast cancer. Future work includes using additional patient-derived tissues (e.g., human fat), and modeling additional organs

  4. MRI appearance of the superior transverse scapular ligament

    Energy Technology Data Exchange (ETDEWEB)

    Simeone, F.J.; Bredella, Miriam A.; Chang, Connie Y.; Torriani, Martin; Huang, Ambrose J. [Massachusetts General Hospital, Department of Radiology, Division of Musculoskeletal Imaging and Intervention, Boston, MA (United States)

    2015-11-15

    The superior transverse scapular ligament (STSL) forms the roof of the suprascapular notch, which is the most common location of entrapment of the suprascapular nerve, a cause of shoulder pain and weakness. The purpose of this study is to determine the frequency of visualization of the STSL on routine shoulder MRIs, to identify the sequences and imaging planes on which it is visualized most frequently, and to describe its typical MRI appearance, none of which have been previously addressed in the radiologic literature. One hundred twenty-one consecutive shoulder MRIs were reviewed for the presence or absence of the STSL, including the imaging plane and sequence that best depicted the ligament. Dimensions of the ligament were recorded. Fifty four of 121 shoulder MRIs were technically adequate for visualization of the STSL, and it was identified on 51 of these studies (94 %). There was no statistically significant difference between 1.5-T and 3-T systems. The best individual sequence for visualizing the STSL was the sagittal T1-weighted sequence, in which the STSL was visible on 75/80 technically adequate sequences (94 %). The sagittal plane was the best plane for visualizing the STSL, in which it was visible on 65/69 technically adequate studies (94 %). The STSL on average measured 12.8 ± 1.5 mm in transverse dimension. The STSL can be visualized on the majority of shoulder MRIs and is best seen on sagittal T1-weighted images on our imaging protocol. Evaluation of the STSL can potentially help in identifying pathologic conditions affecting the suprascapular nerve. (orig.)

  5. Enhanced Rate Capability of Oxide Coated Lithium Titanate within Extended Voltage Ranges

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Dongjoon [College of Engineering, University of Kentucky, Lexington, KY (United States); Xiao, Xingcheng, E-mail: xingcheng.xiao@gm.com [Chemical and Materials Systems Laboratory, General Motors R& D Center, Warren, MI (United States)

    2015-06-30

    Lithium titanate (Li{sub 4}Ti{sub 5}O{sub 12} or LTO) is a promising negative electrode material of high-power lithium-ion batteries, due to its superior rate capability and excellent capacity retention. However, the specific capacity of LTO is less than one half of that of graphite electrode. In this work, we applied ultrathin oxide coating on LTO by the atomic layer deposition technique, aiming for increasing the energy density by extending the cell voltage window and specific capacity of LTO. We demonstrated that a few nanometer thick Al{sub 2}O{sub 3} coating can suppress the mechanical distortion of LTO cycled at low potential, which enable the higher specific capacity and excellent capacity retention. Furthermore, the surface coating can facilitate the charge transfer, leading to significantly improved rate capabilities, comparing with the uncoated LTO.

  6. Turbidity in extreme western Lake Superior. [contamination of Duluth, Minnesota water intake

    Science.gov (United States)

    Sydor, M.

    1975-01-01

    Data were obtained from ERTS images for western Lake Superior for 1972-74. Data examination showed that for easterly winds the turbidity originating along the Wisconsin shore and the resuspension areas are transported northward then out along a N.E. path where it disperses, and often, for large storms, contaminates the Duluth water intake. Contaminants such as dredging fines anywhere along these paths would likewise find their way to the intake areas in concentrations comparable to the relative red clay concentration.

  7. Defense Science Board 1998 Summer Study. Joint Operations Superiority in the 21st Century: Integrating Capabilities Underwriting Joint Vision 2010 and Beyond. Volume 2: Supporting Reports

    National Research Council Canada - National Science Library

    1998-01-01

    .... These supporting challenges include assured knowledge superiority, responsive global targeting, exploitation of the littoral battlespace, inter- and intra-theater mobility, coalition warfare, force...

  8. A rare complication in a child undergoing chemotherapy for acute lymphoblastic leukemia: Superior sagittal sinus thrombosis

    Directory of Open Access Journals (Sweden)

    Ting-Yao Wang

    2011-04-01

    Full Text Available We report the case of a 4-year-old boy with acute lymphoblastic leukemia in high-risk group who suffered from generalized tonic-colonic seizure evolving into status epilepticus, and subsequent left hemiparesis during his first reinduction chemotherapy, consisting of dexamethasone, vincristine, l-asparaginase, and epirubicin. Superior sagittal sinus and cerebral venous thrombosis, predominantly in right side, were proved by brain magnetic resonance imaging. After aggressive treatment with low-molecular weight heparin (LMWH, left hemiparesis improved in 1 week. And he was fully ambulatory 3 weeks later. The second cycle of reinduction chemotherapy was conducted smoothly with the concomitant use of LMWH. This case illustrates the strong correlation of the rare thrombotic complication, superior sagittal sinus thrombosis, and hypercoagulable status secondary to combination use of l-asparaginase and corticosteroid. Early and vigilant recognition of superior sagittal sinus thrombosis and prompt anticoagulation with LMWH may prevent further neurological damage.

  9. Superior versus inferior Ahmed glaucoma valve implantation.

    Science.gov (United States)

    Pakravan, Mohammad; Yazdani, Shahin; Shahabi, Camelia; Yaseri, Mehdi

    2009-02-01

    To compare the efficacy and safety of Ahmed glaucoma valve (AGV) (New World Medical Inc., Rancho Cucamonga, CA) implantation in the superior versus inferior quadrants. Prospective parallel cohort study. A total of 106 eyes of 106 patients with refractory glaucoma. Consecutive patients with refractory glaucoma underwent AGV implantation in the superior or inferior quadrants. Main outcome measures included intraocular pressure (IOP) and rate of complications. Other outcome measures included best corrected visual acuity (BCVA), number of glaucoma medications, and success rate (defined as at least 30% IOP reduction and 5glaucoma surgery, phthisis bulbi, or loss of light perception. Of a total of 106 eyes, 58 and 48 eyes underwent AGV implantation in the superior and inferior quadrants, respectively. Baseline characteristics were comparable in the study groups, except for preoperative IOP, which was higher in the superior group (P = 0.01). Patients were followed for a mean period of 10.6+/-8.49 months and 10.58+/-6.75 months in the superior and inferior groups, respectively (P = 0.477). BCVA was comparable between the groups at all postoperative visits (P>0.122). After 1 year, statistically significant but comparable IOP reduction from baseline (Pglaucoma medications was comparable after 1 year (1.3+/-1.2 vs. 1.9+/-0.8 for superior and inferior implants, respectively, P = 0.256). Success rates were also similar at 1 year: 27 eyes (81.8%) versus 20 eyes (95.2%) for superior and inferior implants, respectively (P = 0.227). However, the overall rate of complications, such as implant exposure necessitating removal, cosmetically unappealing appearance, and endophthalmitis, was higher in the inferior group: 12 eyes (25%) versus 3 eyes (5.2%) for superior and inferior groups, respectively, (P = 0.004). Superior and inferior AGV implants have similar intermediate efficacy in terms of IOP reduction, decrease in number of glaucoma medications, and preservation of vision. However

  10. Absent right superior caval vein in situs solitus

    DEFF Research Database (Denmark)

    Lytzen, Rebekka; Sundberg, Karin; Vejlstrup, Niels

    2015-01-01

    Introduction In up to 0.07% of the general population, the right anterior cardinal vein obliterates and the left remains open, creating an absent right superior caval vein and a persistent left superior caval vein. Absent right superior caval vein is associated with additional congenital heart...... disease in about half the patients. We wished to study the consequences of absent right superior caval vein as an incidental finding on prenatal ultrasonic malformation screening. Material and methods This is a retrospective case series study of all foetuses diagnosed with absent right superior caval vein...... no postnatal complications. All children were found to have healthy hearts at follow-up. CONCLUSIONS: In all cases, the findings proved to be a benign condition with no clinical manifestations or complications. Although isolated absent right superior caval vein does not seem to affect the outcome, associated...

  11. Bayesian image restoration for medical images using radon transform

    International Nuclear Information System (INIS)

    Shouno, Hayaru; Okada, Masato

    2010-01-01

    We propose an image reconstruction algorithm using Bayesian inference for Radon transformed observation data, which often appears in the field of medical image reconstruction known as computed tomography (CT). In order to apply our Bayesian reconstruction method, we introduced several hyper-parameters that control the ratio between prior information and the fidelity of the observation process. Since the quality of the reconstructed image is influenced by the estimation accuracy of these hyper-parameters, we propose an inference method for them based on the marginal likelihood maximization principle as well as the image reconstruction method. We are able to demonstrate a reconstruction result superior to that obtained using the conventional filtered back projection method. (author)

  12. Distinct interjoint coordination during fast alternate keystrokes in pianists with superior skill

    Directory of Open Access Journals (Sweden)

    Shinichi eFuruya

    2011-05-01

    Full Text Available Musical performance requires motor skills to coordinate the movements of multiple joints in the hand and arm over a wide range of tempi. However, it is unclear whether the coordination of movement across joints would differ for musicians with different skill levels and how inter-joint coordination would vary in relation to music tempo. The present study addresses these issues by examining the kinematics and muscular activity of the hand and arm movements of professional and amateur pianists who strike two keys alternately with the thumb and little finger at various tempi. The professionals produced a smaller flexion velocity at the thumb and little finger and greater elbow pronation and supination velocity than did the amateurs. The experts also showed smaller extension angles at the metacarpo-phalangeal joint of the index and middle fingers, which were not being used to strike the keys. Furthermore, muscular activity in the extrinsic finger muscles was smaller for the experts than for the amateurs. These findings indicate that pianists with superior skill reduce the finger muscle load during keystrokes by taking advantage of differences in proximal joint motion and hand postural configuration. With an increase in tempo, the experts showed larger and smaller increases in elbow velocity and finger muscle co-activation, respectively, compared to the amateurs, highlighting skill-level-dependent differences in movement strategies for tempo adjustment. Finally, when striking as fast as possible, individual differences in the striking tempo among players were explained by their elbow velocities but not by their digit velocities. These findings suggest that pianists who are capable of faster keystrokes benefit more from proximal joint motion than do pianists who are not capable of faster keystrokes. The distinct movement strategy for tempo adjustment in pianists with superior skill would therefore ensure a wider range of musical expression.

  13. Single-photon imaging

    CERN Document Server

    Seitz, Peter

    2011-01-01

    The acquisition and interpretation of images is a central capability in almost all scientific and technological domains. In particular, the acquisition of electromagnetic radiation, in the form of visible light, UV, infrared, X-ray, etc. is of enormous practical importance. The ultimate sensitivity in electronic imaging is the detection of individual photons. With this book, the first comprehensive review of all aspects of single-photon electronic imaging has been created. Topics include theoretical basics, semiconductor fabrication, single-photon detection principles, imager design and applications of different spectral domains. Today, the solid-state fabrication capabilities for several types of image sensors has advanced to a point, where uncoooled single-photon electronic imaging will soon become a consumer product. This book is giving a specialist´s view from different domains to the forthcoming “single-photon imaging” revolution. The various aspects of single-photon imaging are treated by internati...

  14. MARKETING CAPABILITIES FOR INNOVATION-BASED COMPETITIVE ADVANTAGE IN THE SLOVENIAN MARKET

    Directory of Open Access Journals (Sweden)

    Vojko Potocan

    2013-01-01

    Full Text Available The primary role of marketing within the competitive advantage is innovation. The customer value-based differentiation strategies will drive the company’s market research efforts, its selection of target markets, its product development processes, its market communications programs, and its delivery processes. These processes require many specific capabilities that enable the firm to carry out activities necessary to move its products or services through the value chain. We must explore the role of distinctive marketing capabilities in competitive strategy of the company. As sources of competitive advantage, companies try to create their product or service differentiation by developing higher product or service quality, by using their knowledge to solving marketing problems, by communicating with their customers, and by satisfying customer’s needs. We also would like to confirm that superior customer service lead to company’s innovation. The paper closes with the implications of the findings and highlights promising future research avenues.

  15. Single-photon imaging

    International Nuclear Information System (INIS)

    Seitz, Peter; Theuwissen, Albert J.P.

    2011-01-01

    The acquisition and interpretation of images is a central capability in almost all scientific and technological domains. In particular, the acquisition of electromagnetic radiation, in the form of visible light, UV, infrared, X-ray, etc. is of enormous practical importance. The ultimate sensitivity in electronic imaging is the detection of individual photons. With this book, the first comprehensive review of all aspects of single-photon electronic imaging has been created. Topics include theoretical basics, semiconductor fabrication, single-photon detection principles, imager design and applications of different spectral domains. Today, the solid-state fabrication capabilities for several types of image sensors has advanced to a point, where uncooled single-photon electronic imaging will soon become a consumer product. This book is giving a specialist's view from different domains to the forthcoming ''single-photon imaging'' revolution. The various aspects of single-photon imaging are treated by internationally renowned, leading scientists and technologists who have all pioneered their respective fields. (orig.)

  16. Progressive gray matter reduction of the superior temporal gyrus during transition to psychosis.

    Science.gov (United States)

    Takahashi, Tsutomu; Wood, Stephen J; Yung, Alison R; Soulsby, Bridget; McGorry, Patrick D; Suzuki, Michio; Kawasaki, Yasuhiro; Phillips, Lisa J; Velakoulis, Dennis; Pantelis, Christos

    2009-04-01

    Longitudinal magnetic resonance imaging studies have shown progressive gray matter reduction in the superior temporal gyrus during the earliest phases of schizophrenia. It is unknown whether these progressive processes predate the onset of psychosis. To examine gray matter reduction of the superior temporal gyrus over time in individuals at risk for psychosis and in patients with first-episode psychosis. Cross-sectional and longitudinal comparisons. Personal Assessment and Crisis Evaluation Clinic and Early Psychosis Preventions and Intervention Centre. Thirty-five ultrahigh-risk individuals (of whom 12 later developed psychosis [UHRP] and 23 did not [UHRNP]), 23 patients with first-episode psychosis (FEP), and 22 control subjects recruited from the community. Volumes of superior temporal subregions (planum polare, Heschl gyrus, planum temporale, and rostral and caudal regions) were measured at baseline and follow-up (mean, 1.8 years) and were compared across groups. In cross-sectional comparisons, only the FEP group had significantly smaller planum temporale and caudal superior temporal gyrus than other groups at baseline, whereas male UHRP subjects also had a smaller planum temporale than controls at follow-up. In longitudinal comparison, UHRP and FEP patients showed significant gray matter reduction (approximately 2%-6% per year) in the planum polare, planum temporale, and caudal region compared with controls and/or UHRNP subjects. The FEP patients also exhibited progressive gray matter loss in the left Heschl gyrus (3.0% per year) and rostral region (3.8% per year), which were correlated with the severity of delusions at follow-up. A progressive process in the superior temporal gyrus precedes the first expression of florid psychosis. These findings have important implications for underlying neurobiologic features of emerging psychotic disorders and emphasize the importance of early intervention during or before the first episode of psychosis.

  17. Image fusion between whole body FDG PET images and whole body MRI images using a full-automatic mutual information-based multimodality image registration software

    International Nuclear Information System (INIS)

    Uchida, Yoshitaka; Nakano, Yoshitada; Fujibuchi, Toshiou; Isobe, Tomoko; Kazama, Toshiki; Ito, Hisao

    2006-01-01

    We attempted image fusion between whole body PET and whole body MRI of thirty patients using a full-automatic mutual information (MI) -based multimodality image registration software and evaluated accuracy of this method and impact of the coregistrated imaging on diagnostic accuracy. For 25 of 30 fused images in body area, translating gaps were within 6 mm in all axes and rotating gaps were within 2 degrees around all axes. In head and neck area, considerably much gaps caused by difference of head inclination at imaging occurred in 16 patients, however these gaps were able to decrease by fused separately. In 6 patients, diagnostic accuracy using PET/MRI fused images was superior compared by PET image alone. This work shows that whole body FDG PET images and whole body MRI images can be automatically fused using MI-based multimodality image registration software accurately and this technique can add useful information when evaluating FDG PET images. (author)

  18. Research and Development of a portable microfocus x-ray system capable of providing ultra-high resolutions images of improvised explosive devices

    International Nuclear Information System (INIS)

    Korkala, G.

    1989-01-01

    The utilization of x-ray screening has long been a recognized valuable tool as a means to evaluate and identify suspect articles for possible improvised explosive devices. Recent bombings indicate an increase in technical sophistication by the terrorist which demand additional means to further the possibility of detecting these devices before they reach their target or detonate. This paper discusses history of the use of x-ray and the design parameters of a portable micro-focus x-ray system capable of providing ultra high resolution radiographs as well as being able to be used with additional state-of-the-art imaging systems

  19. New and superior adrenal scanning agent, NP-59

    International Nuclear Information System (INIS)

    Sarkar, S.D.; Beierwaltes, W.H.; Ice, R.D.; Basmadjian, G.P.; Hertzel, K.R.; Kennedy, W.P.; Mason, M.M.

    1975-01-01

    The first synthesis of 131 I-19-iodocholesterol had a 10 to 25 percent radiochemical impurity that was not iodide ion. This impurity has been identified as 6β- 131 I-iodomethyl-19-nor cholest-5(10)-en-3β-ol (NP-59) and has been synthesized. Tissue distribution studies with 131 I-NP-59 in rats and dogs revealed a higher adrenal uptake and adrenal-to-tissue ratios compared to 131 I 19-iodocholesterol, probably less in vivo deiodination, and superior adrenal images. A high uptake was seen in the adrenal medulla in addition to that in the cortex. Iodine-131-NP-59 is being evaluated for the early detection of adrenal--cortical disorders and as a potential scanning agent for detecting structural abnormalities of the adrenal medulla

  20. Capability of Raman lidar for monitoring the variation of atmospheric CO2 profile

    International Nuclear Information System (INIS)

    Zhao Peitao; Hu Shunxing; Su Jia; Cao Kaifa; Hu Huanling; Zhang Yinchao; Wang Lian; Zhao Yuefeng

    2008-01-01

    Lidar (Light detection and ranging) has special capabilities for remote sensing of many different behaviours of the atmosphere. One of the techniques which show a great deal of promise for several applications is Raman scattering. The detecting capability, including maximum operation range and minimum detectable gas concentration is one of the most significant parameters for lidar remote sensing of pollutants. In this paper, based on the new method for evaluating the capabilities of a Raman lidar system, we present an evaluation of detecting capability of Raman lidar for monitoring atmospheric CO 2 in Hefei. Numerical simulations about the influence of atmospheric conditions on lidar detecting capability were carried out, and a conclusion can be drawn that the maximum difference of the operation ranges caused by the weather conditions alone can reach about 0.4 to 0.5km with a measuring precision within 30ppmv. The range of minimum detectable concentration caused by the weather conditions alone can reach about 20 to 35 ppmv in vertical direction for 20000 shots at a distance of 1 km on the assumption that other parameters are kept constant. The other corresponding parameters under different conditions are also given. The capability of Raman lidar operated in vertical direction was found to be superior to that operated in horizontal direction. During practical measurement with the Raman lidar whose hardware components were fixed, aerosol scattering extinction effect would be a significant factor that influenced the capability of Raman lidar. This work may be a valuable reference for lidar system designing, measurement accuracy improving and data processing

  1. Intraoperative imaging for patient safety and QA: detection of intracranial hemorrhage using C-arm cone-beam CT

    Science.gov (United States)

    Schafer, Sebastian; Wang, Adam; Otake, Yoshito; Stayman, J. W.; Zbijewski, Wojciech; Kleinszig, Gerhard; Xia, Xuewei; Gallia, Gary L.; Siewerdsen, Jeffrey H.

    2013-03-01

    Intraoperative imaging could improve patient safety and quality assurance (QA) via the detection of subtle complications that might otherwise only be found hours after surgery. Such capability could therefore reduce morbidity and the need for additional intervention. Among the severe adverse events that could be more quickly detected by high-quality intraoperative imaging is acute intracranial hemorrhage (ICH), conventionally assessed using post-operative CT. A mobile C-arm capable of high-quality cone-beam CT (CBCT) in combination with advanced image reconstruction techniques is reported as a means of detecting ICH in the operating room. The system employs an isocentric C-arm with a flat-panel detector in dual gain mode, correction of x-ray scatter and beam-hardening, and a penalized likelihood (PL) iterative reconstruction method. Performance in ICH detection was investigated using a quantitative phantom focusing on (non-contrast-enhanced) blood-brain contrast, an anthropomorphic head phantom, and a porcine model with injection of fresh blood bolus. The visibility of ICH was characterized in terms of contrast-to-noise ratio (CNR) and qualitative evaluation of images by a neurosurgeon. Across a range of size and contrast of the ICH as well as radiation dose from the CBCT scan, the CNR was found to increase from ~2.2-3.7 for conventional filtered backprojection (FBP) to ~3.9-5.4 for PL at equivalent spatial resolution. The porcine model demonstrated superior ICH detectability for PL. The results support the role of high-quality mobile C-arm CBCT employing advanced reconstruction algorithms for detecting subtle complications in the operating room at lower radiation dose and lower cost than intraoperative CT scanners and/or fixedroom C-arms. Such capability could present a potentially valuable aid to patient safety and QA.

  2. Hypothalamo-pituitary imaging

    International Nuclear Information System (INIS)

    Vezina, J.L.

    1995-01-01

    That is with the Nuclear Magnetic resonance (NMR) imaging that our exploration has its excellence top. NMR has a great superiority by its high resolution in contrast allowing to signal the presence of abnormal tissue in a sane organ. 5 refs. 2 figs

  3. Security surveillance challenges and proven thermal imaging capabilities in real-world applications

    Science.gov (United States)

    Francisco, Glen L.; Roberts, Sharon

    2004-09-01

    Uncooled thermal imaging was first introduced to the public in early 1980's by Raytheon (legacy Texas Instruments Defense Segment Electronics Group) as a solution for military applications. Since the introduction of this technology, Raytheon has remained the leader in this market as well as introduced commercial versions of thermal imaging products specifically designed for security, law enforcement, fire fighting, automotive and industrial uses. Today, low cost thermal imaging for commercial use in security applications is a reality. Organizations of all types have begun to understand the advantages of using thermal imaging as a means to solve common surveillance problems where other popular technologies fall short. Thermal imaging has proven to be a successful solution for common security needs such as: ¸ vision at night where lighting is undesired and 24x7 surveillance is needed ¸ surveillance over waterways, lakes and ports where water and lighting options are impractical ¸ surveillance through challenging weather conditions where other technologies will be challenged by atmospheric particulates ¸ low maintenance requirements due to remote or difficult locations ¸ low cost over life of product Thermal imaging is now a common addition to the integrated security package. Companies are relying on thermal imaging for specific applications where no other technology can perform.

  4. MR imaging of articular cartilage disorders: Specificity of fast imaging and CHESS

    International Nuclear Information System (INIS)

    Konig, H.; Sauter, R.; Kueper, K.; Deimling, M.; Vogt, M.

    1986-01-01

    MR imaging is the first imaging method that allows visualization of cartilage tissues. The authors compared standard spin-echo sequences and selective water images obtained using the CHESS method as well as fast sequences in patients with inflammatory, degenerative, and traumatic alterations of the hip, knee, and radiocarpal joint. Measurements were carried out using Magnetom imaging systems operating at 1.0 and 1.5 T. With the use of different types of surface coils high spatial resolution (pixel size, 0.5-1.0 mm; section thickness, 3-8 mm) could be obtained. Pure water images are superior for showing changes of the hyaline cartilage, whereas spin-echo sequences remain the basic procedure, especially for imaging fibrocartilage disorders

  5. Super-resolution post-processing for satellites with yaw-steering capability

    CSIR Research Space (South Africa)

    Van den Dool, R

    2012-10-01

    Full Text Available We describe a method for improving Earth observation satellite image resolution, for specific areas of interest where the sensor design resolution is insufficient. Our method may be used for satellites with yaw-steering capability, such as Nigeria...

  6. Fat saturation in dynamic breast MRI at 3 Tesla: is the Dixon technique superior to spectral fat saturation? A visual grading characteristics study

    Energy Technology Data Exchange (ETDEWEB)

    Clauser, P. [University of Udine, Azienda Ospedaliero-Universitaria ' ' S.Maria della Misericordia' ' , Institute of Diagnostic Radiology, Udine (Italy); Medical University of Vienna, Department of Biomedical Imaging and Image-guided interventions, Division of Molecular and Gender Imaging, Vienna (Austria); Pinker, K.; Helbich, T.H.; Kapetas, P.; Bernathova, M.; Baltzer, P.A.T. [Medical University of Vienna, Department of Biomedical Imaging and Image-guided interventions, Division of Molecular and Gender Imaging, Vienna (Austria)

    2014-09-15

    To intra-individually compare the diagnostic image quality of Dixon and spectral fat suppression at 3 T. Fifty consecutive patients (mean age 55.1 years) undergoing 3 T breast MRI were recruited for this prospective study. The image protocol included pre-contrast and delayed post-contrast spectral and Dixon fat-suppressed T1w series. Two independent blinded readers compared spectral and Dixon fat-suppressed series by evaluating six ordinal (1 worst to 5 best) image quality criteria (image quality, delineation of anatomical structures, fat suppression in the breast and axilla, lesion delineation and internal enhancement). Breast density and size were assessed. Data analysis included Spearman's rank correlation coefficient and visual grading characteristics (VGC) analysis. Four examinations were excluded; 48 examinations in 46 patients were evaluated. In VGC analysis, the Dixon technique was superior regarding image quality criteria analysed (P < 0.01). Smaller breast size and lower breast density were significantly (P < 0.01) correlated with impaired spectral fat suppression quality. No such correlation was identified for the Dixon technique, which showed reconstruction-based water-fat mixups leading to insufficient image quality in 20.8 %. The Dixon technique outperformed spectral fat suppression in all evaluated criteria (P < 0.01). Non-diagnostic examinations can be avoided by fat and water image reconstruction. The superior image quality of the Dixon technique can improve breast MRI interpretation. (orig.)

  7. Bladder segmentation in MR images with watershed segmentation and graph cut algorithm

    Science.gov (United States)

    Blaffert, Thomas; Renisch, Steffen; Schadewaldt, Nicole; Schulz, Heinrich; Wiemker, Rafael

    2014-03-01

    Prostate and cervix cancer diagnosis and treatment planning that is based on MR images benefit from superior soft tissue contrast compared to CT images. For these images an automatic delineation of the prostate or cervix and the organs at risk such as the bladder is highly desirable. This paper describes a method for bladder segmentation that is based on a watershed transform on high image gradient values and gray value valleys together with the classification of watershed regions into bladder contents and tissue by a graph cut algorithm. The obtained results are superior if compared to a simple region-after-region classification.

  8. Superior mesenteric artery syndrome causing growth retardation

    Directory of Open Access Journals (Sweden)

    Halil İbrahim Taşcı

    2013-03-01

    Full Text Available Superior mesenteric artery syndrome is a rare and lifethreateningclinical condition caused by the compressionof the third portion of the duodenum between the aortaand the superior mesenteric artery’s proximal part. Thiscompression may lead to chronic intermittent, acute totalor partial obstruction. Sudden weight-loss and the relateddecrease in the fat tissue are considered to be the etiologicalreason of acute stenosis. Weight-loss accompaniedby nausea, vomiting, anorexia, epigastric pain, andbloating are the leading complaints. Barium radiographs,computerized tomography, conventional angiography,tomographic and magnetic resonance angiography areused in the diagnosis. There are medical and surgical approachesto treatment. We hereby present the case ofa patient with superior mesenteric artery syndrome withdelayed diagnosis.Key words: superior mesenteric artery syndrome, nausea-vomiting, anorexia

  9. Anatomy of right superior septal artery demonstrated on the coronary CT scan

    International Nuclear Information System (INIS)

    Takeguchi, Takaya; Ibukuro, Kenji; Fukuda, Hozumi; Tobe, Kimiko; Abe, Shoko

    2012-01-01

    Background. A coronary CT scan allows for non-invasive visualization of the anatomy of a coronary artery in three dimensions compared to the two dimensions afforded by conventional angiography. The septal artery, the main blood source of the interventricular septum, is usually derived from the left anterior descending artery; however, it is occasionally derived from the right coronary artery. Purpose. To analyze the prevalence, origin, diameter, and length of the right superior septal artery (RSSA) demonstrated on a coronary CT scan. Material and Methods. The right superior septal artery was retrospectively reviewed on the reconstructed axial scan images (0.5-mm thickness, 0.25-mm interval) in 1290 consecutive patients who underwent coronary CT scans. All patients were scanned on a 320-row CT scanner. The images were transferred to a workstation to trace the vessel to analyze the origin, diameter, and length. We also compared the length of the RSSA between patients with and without coronary artery stenosis. Results. The RSSA was identified in 51 (3.9%) of 1290 patients. The origin was the proximal portion of the right coronary artery (n = 40) or the right sinus of Valsalva (n 11). The artery co-existed with the conus artery in 15 (29%) of 51 patients. The length was 16-62 mm (mean 31.2 mm ± 10.5), and the diameter was 0.8-2.0 mm (mean 1.3 mm ± 0.2). Longer RSSAs tended to be demonstrated in the patients with coronary artery stenosis rather than with normal coronary arteries (P < 0.05). Conclusion. The right superior septal artery and its anatomical variant could be analyzed with a coronary CT scan. The ability to demonstrate this artery on the coronary CT scan was the same as with coronary angiography. The recognition of this vessel is useful for physicians managing with the diagnosis and treatment of the coronary artery disease

  10. Specific marker of feigned memory impairment: The activation of left superior frontal gyrus.

    Science.gov (United States)

    Chen, Zi-Xiang; Xue, Li; Liang, Chun-Yu; Wang, Li-Li; Mei, Wei; Zhang, Qiang; Zhao, Hu

    2015-11-01

    Faking memory impairment means normal people complain lots of memory problems without organic damage in forensic assessments. Using alternative forced-choice paradigm, containing digital or autobiographical information, previous neuroimaging studies have indicated that faking memory impairment could cause the activation in the prefrontal and parietal regions, and might involve a fronto-parietal-subcortical circuit. However, it is still unclear whether different memory types have influence on faking or not. Since different memory types, such as long-term memory (LTM) and short-term memory (STM), were found supported by different brain areas, we hypothesized that feigned STM or LTM impairment had distinct neural activation mapping. Besides that, some common neural correlates may act as the general characteristic of feigned memory impairment. To verify this hypothesis, the functional magnetic resonance imaging (fMRI) combined with an alternative word forced-choice paradigm were used in this study. A total of 10 right-handed participants, in this study, had to perform both STW and LTM tasks respectively under answering correctly, answering randomly and feigned memory impairment conditions. Our results indicated that the activation of the left superior frontal gyrus and the left medial frontal gyrus was associated with feigned LTM impairment, whereas the left superior frontal gyrus, the left precuneus and the right anterior cingulate cortex (ACC) were highly activated while feigning STM impairment. Furthermore, an overlapping was found in the left superior frontal gyrus, and it suggested that the activity of the left superior frontal gyrus might be acting as a specific marker of feigned memory impairment. Copyright © 2015. Published by Elsevier Ltd.

  11. A Novel Method for Intraoral Access to the Superior Head of the Human Lateral Pterygoid Muscle

    Directory of Open Access Journals (Sweden)

    Aleli Tôrres Oliveira

    2014-01-01

    Full Text Available Background. The uncoordinated activity of the superior and inferior parts of the lateral pterygoid muscle (LPM has been suggested to be one of the causes of temporomandibular joint (TMJ disc displacement. A therapy for this muscle disorder is the injection of botulinum toxin (BTX, of the LPM. However, there is a potential risk of side effects with the injection guide methods currently available. In addition, they do not permit appropriate differentiation between the two bellies of the muscle. Herein, a novel method is presented to provide intraoral access to the superior head of the human LPM with maximal control and minimal hazards. Methods. Computational tomography along with digital imaging software programs and rapid prototyping techniques were used to create a rapid prototyped guide to orient BTX injections in the superior LPM. Results. The method proved to be feasible and reliable. Furthermore, when tested in one volunteer it allowed precise access to the upper head of LPM, without producing side effects. Conclusions. The prototyped guide presented in this paper is a novel tool that provides intraoral access to the superior head of the LPM. Further studies will be necessary to test the efficacy and validate this method in a larger cohort of subjects.

  12. MRI imaging and staging of atlantodental lesions in rheumatoid arthritis

    International Nuclear Information System (INIS)

    Kuroda, Mana

    1992-01-01

    Sixty-five patients with a 3 year or more history of rheumatoid arthritis (RA) underwent magentic resonance (MR) imaging to determine the atlantodental interval (ADI), space available for the spinal cord (SAC), intensity of dens, dense erosion, periodontoid masses, and atlantodental subluxation. These MR findings were classified into stages 0 to IV. Stenbroker stage, disease duration, clinical symptoms, and ADI were compared with MR stages. Gd-DTPA enhanced MR images of the craniovertebral junction were also obtained in 16 patients with obvious periodontal pannus to examine a relationship between uptake of Gd-DTPA and quantitative C-reactive protein (CRP), erythrocyte sedimentation rate (ESR), and the joint score as the marker of the activity. Steinbroker stage, disease duration, and clinical symptoms were not correlaed with MR stage of craniovertebral junction. MR imaging was capable of detecting periodontoid lesion even in the early stage. It was also superior to conventional plain film and tomography in depicting the retrodental pannus without ADI dilatation. Pannus having noticeable contrast enhancement was associated with an extremely increased CRP and ESR. When it had no increase in signal intensity, laboratory findings were various. MR enhancement pattern seemed to correlate with RA activity. The present MR classification of atlantodental lesions would contribute to the therapeutic decision and evaluation of treatment outcome. (N.K.)

  13. MRI imaging and staging of atlantodental lesions in rheumatoid arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Kuroda, Mana (Tokyo Medical Coll. (Japan))

    1992-03-01

    Sixty-five patients with a 3 year or more history of rheumatoid arthritis (RA) underwent magentic resonance (MR) imaging to determine the atlantodental interval (ADI), space available for the spinal cord (SAC), intensity of dens, dense erosion, periodontoid masses, and atlantodental subluxation. These MR findings were classified into stages 0 to IV. Stenbroker stage, disease duration, clinical symptoms, and ADI were compared with MR stages. Gd-DTPA enhanced MR images of the craniovertebral junction were also obtained in 16 patients with obvious periodontal pannus to examine a relationship between uptake of Gd-DTPA and quantitative C-reactive protein (CRP), erythrocyte sedimentation rate (ESR), and the joint score as the marker of the activity. Steinbroker stage, disease duration, and clinical symptoms were not correlaed with MR stage of craniovertebral junction. MR imaging was capable of detecting periodontoid lesion even in the early stage. It was also superior to conventional plain film and tomography in depicting the retrodental pannus without ADI dilatation. Pannus having noticeable contrast enhancement was associated with an extremely increased CRP and ESR. When it had no increase in signal intensity, laboratory findings were various. MR enhancement pattern seemed to correlate with RA activity. The present MR classification of atlantodental lesions would contribute to the therapeutic decision and evaluation of treatment outcome. (N.K.).

  14. Toward Superior Capacitive Energy Storage: Recent Advances in Pore Engineering for Dense Electrodes.

    Science.gov (United States)

    Liu, Congcong; Yan, Xiaojun; Hu, Fei; Gao, Guohua; Wu, Guangming; Yang, Xiaowei

    2018-04-01

    With the rapid development of mobile electronics and electric vehicles, future electrochemical capacitors (ECs) need to store as much energy as possible in a rather limited space. As the core component of ECs, dense electrodes that have a high volumetric energy density and superior rate capability are the key to achieving improved energy storage. Here, the significance of and recent progress in the high volumetric performance of dense electrodes are presented. Furthermore, dense yet porous electrodes, as the critical precondition for realizing superior electrochemical capacitive energy, have become a scientific challenge and an attractive research focus. From a pore-engineering perspective, insight into the guidelines of engineering the pore size, connectivity, and wettability is provided to design dense electrodes with different porous architectures toward high-performance capacitive energy storage. The current challenges and future opportunities toward dense electrodes are discussed and include the construction of an orderly porous structure with an appropriate gradient, the coupling of pore sizes with the solvated cations and anions, and the design of coupled pores with diverse electrolyte ions. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Lyophilized skeletal imaging composition

    International Nuclear Information System (INIS)

    Vanduzee, B.F.

    1983-01-01

    This invention encompasses a process for producing a dry-powder skeletal imaging kit. An aqueous solution of a diphosphonate, a stannous reductant, and, optionally, a stabilizer is prepared. The solution is adjusted to a pH within the range 4.2 to 4.8 and the pH-adjusted solution is then lyophilized. The adjustment of pH, within a particular range, during the process of manufacturing lyophilized diphosphonate containing skeletal imaging kits yields a kit which produces a technetium skeletal imaging agent with superior imaging properties. This improved performance is manifested through faster blood clearance and higher skeletal uptake of the technetium imaging agent

  16. Sports-related groin pain: evaluation with MR imaging

    International Nuclear Information System (INIS)

    Ekberg, O.; Sjoeberg, S.; Westlin, N.

    1996-01-01

    Our purpose was to assess the role of MRI in evaluating the musculoskeletal system in athletes with chronic pain laterally in the groin of unknown etiology. Magnetic resonance imaging (MRI) of the public ring was performed in 11 young athletes (soccer players) with long-standing groin pain. MR findings were compared with plain films and isotope examination (bone scan Tc99M). Abnormal MRI findings included a broadened and irregular symphysis with a characteristic pattern of low signal intensity on T1W and high signal intensity on T2W images localized in the superior public ramus at a distance from the symphysis. Positive findings were also observed on plaon films and on nuclear medicine studies. However, the imaging findings in the superior pubic ramus of the symphysis was located considerably more laterally on MRI. MRI is a valuable method for evaluating discrete and ambiguous pelvic pain in athletes, particularly for identifying concomitant changes in the superior ramus, which may give rise to long-standing pain localized laterally in the groin. (orig.)

  17. MR imaging in sports-related glenohumeral instability

    International Nuclear Information System (INIS)

    Woertler, Klaus; Waldt, Simone

    2006-01-01

    Sports-related shoulder pain and injuries represent a common problem. In this context, glenohumeral instability is currently believed to play a central role either as a recognized or as an unrecognized condition. Shoulder instabilities can roughly be divided into traumatic, atraumatic, and microtraumatic glenohumeral instabilities. In athletes, atraumatic and microtraumatic instabilities can lead to secondary impingement syndromes and chronic damage to intraarticular structures. Magnetic resonance (MR) arthrography is superior to conventional MR imaging in the diagnosis of labro-ligamentous injuries, intrinsic impingement, and SLAP (superior labral anteroposterior) lesions, and thus represents the most informative imaging modality in the overall assessment of glenohumeral instability. This article reviews the imaging criteria for the detection and classification of instability-related injuries in athletes with special emphasis on the influence of MR findings on therapeutic decisions. (orig.)

  18. Study on the usefulness of whole body SPECT coronal image, MIP image in 67Ga scintigraphy

    International Nuclear Information System (INIS)

    Kawamura, Seiji

    2002-01-01

    In this study, we examined the usefulness of whole body coronal images and whole body cine display MIP images (CMIP) upon which image processing was carried out after whole body SPECT in comparison to the usefulness of whole body images (WB/SC) compensated by scattered radiation in tumor/inflammation scintigraphy with 67 Ga-citrate ( 67 Ga). Image interpretation was performed for the 120 patients with confirmed diagnoses, and the accuracy of their diagnoses was studied by three nuclear medical physicians and two clinical radiological technologists by means of sensitivity, specificity and ROC analysis. The resultant data show that sensitivity, specificity, accuracy and the area under the ROC curve Az in the WB/SC were approximately 65%, 86%, 74% and 0.724, respectively, whereas sensitivity, specificity, accuracy and Az of the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method were approximately 93%, 95%, 94% and 0.860, respectively. Furthermore, coronal images reconstructed by the OS-EM method tended to be superior to those produced by the FBP method in both diagnostic accuracy and ROC analysis. In conclusion, the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method was shown to be superior in diagnostic accuracy and ROC analysis. Our data suggest that whole body SPECT is an excellent technique as an alternative to WB/SC. (author)

  19. Percutaneous augmentation of the superior pubic ramus with polymethyl methacrylate: treatment of acute traumatic and chronic insufficiency fractures

    Energy Technology Data Exchange (ETDEWEB)

    Beall, Douglas P. [University of Oklahoma, Clinical Radiology of Oklahoma, Oklahoma City, OK (United States); D' Souza, Sharon L. [University of Oklahoma, Oklahoma City, OK (United States); Costello, Richard F.; Stapp, Annette M. [Clinical Radiology of Oklahoma, Edmond, OK (United States); Prater, Scott D. [University of Oklahoma College of Medicine, Edmond, OK (United States); Van Zandt, Bryan L. [University of Oklahoma College of Medicine, Oklahoma City, OK (United States); Martin, Hal D. [Oklahoma Sports Science and Orthopaedics, Oklahoma City, OK (United States)

    2007-10-15

    The injection of polymethylmethacrylate (PMMA) is a minimally invasive image-guided procedure that is typically used to treat vertebral body fractures due to osteoporosis or neoplastic involvement. The injection of PMMA into various other locations including the sacrum, acetabulum, pedicles, femur and tibia has been reported previously, and these procedures have, overall, been highly effective at alleviating pain and discomfort. Although the injection of PMMA into the vertebral body is a very common procedure that has been performed for over 2 decades for the percutaneous treatment of vertebral body fractures, the percutaneous injection of PMMA has not been reported in the English literature as treatment for superior pubic ramus fractures. We report the percutaneous treatment of an acute superior pubic ramus fracture and of a chronic insufficiency fracture of the superior pubic ramus using a parasymphyseal approach to access the region of injury. (orig.)

  20. Neutron imaging and applications a reference for the imaging community

    CERN Document Server

    McGreevy, Robert L; Bilheux, Hassina Z

    2009-01-01

    Offers an introduction to the basics of neutron beam production in addition to the wide scope of techniques that enhance imaging application capabilities. This title features a section that describes imaging single grains in polycrystalline materials, neutron imaging of geological materials and other materials science and engineering areas.

  1. Contrast-enhanced fast fluid-attenuated inversion recovery MR imaging in patients with brain tumors

    International Nuclear Information System (INIS)

    Kim, Chan Kyo; Na, Dong Gyu; Ryoo, Wook Jae; Byun Hong Sik; Yoon, Hye Kyung; Kim, Jong hyun

    2000-01-01

    To assess the feasibility of contrast-enhanced fast fluid-attenuated inversion recovery (fast FLAIR) MR imaging in patients with brain tumors. This study involved 31 patients with pathologically proven brain tumors and nine with clinically diagnosed metastases. In all patients, T2-weighted, fast FLAIR, images were visual contrast-enhanced T1-weighted MR images were obtained. Contrast-enhanced fast FLAIR images were visually compared with other MR sequences in terms of tumor conspicuity. In order to distinguish tumor and surrounding edema, contrast-enhanced fast FLAIR images were compared with fast FLAIR and T2-weighted images. The tumor-to- white matter contrast-to-noise ratios (CNRs), as demonstrated by T2-weighted, fast FLAIR, contrast-enhanced fast FLAIR and contrast-enhanced T1-weighted imaging, were quantitatively assessed and compared. For the visual assessment of tumor conspicuity, contrast-enhanced fast FLAIR image imaging superior to fast FLAIR in 60% of cases (24/40), and superior to T2-weighted in 70% (28/40). Contrast-enhanced fast FLAIR imaging was inferior to contrast-enhanced T1-weighted in 58% of cases (23/40). For distinguishing between tumor and surrounding edema, contrast-enhanced fast FLAIR imaging was superior to fast FLAIR or T2-weighted in 22 of 27 tumors with peritumoral edema (81%). Quantitatively, CNR was the highest on contrast-enhanced fast FLAIR image and the lowest on fast FLAIR. For the detection of leptomeningeal metastases, contrast-enhanced fast FLAIR was partially superior to contrast-enhanced T1-weighted imaging in two of three high-grade gliomas. Although contrast-enhanced fast FLAIR imaging should not be seen as a replacement for conventional modalities, it provides additional informaton for assessment of the extent of glial cell tumors and leptomeningeal metastases in patients with brain tumors. (author)

  2. Impact of Personnel Capabilities on Organizational Innovation Capability

    DEFF Research Database (Denmark)

    Nielsen, Susanne Balslev; Momeni, Mostafa

    2016-01-01

    in this rapidly changing world. This research focuses on definition of the personnel aspect of innovation capability, and proposes a conceptual model based on the scientific articles of academic literature on organisations innovation capability. This paper includes an expert based validation in three rounds...... of the Delphi method. And for the purpose of a better appreciation of the relationship dominating the factors of the model, it has distributed the questionnaire to Iranian companies in the Food industry. This research proposed a direct relationship between Innovation Capability and the Personnel Capability...

  3. Best linear decoding of random mask images

    International Nuclear Information System (INIS)

    Woods, J.W.; Ekstrom, M.P.; Palmieri, T.M.; Twogood, R.E.

    1975-01-01

    In 1968 Dicke proposed coded imaging of x and γ rays via random pinholes. Since then, many authors have agreed with him that this technique can offer significant image improvement. A best linear decoding of the coded image is presented, and its superiority over the conventional matched filter decoding is shown. Experimental results in the visible light region are presented. (U.S.)

  4. PET/MRI in Oncological Imaging: State of the Art

    Science.gov (United States)

    Bashir, Usman; Mallia, Andrew; Stirling, James; Joemon, John; MacKewn, Jane; Charles-Edwards, Geoff; Goh, Vicky; Cook, Gary J.

    2015-01-01

    Positron emission tomography (PET) combined with magnetic resonance imaging (MRI) is a hybrid technology which has recently gained interest as a potential cancer imaging tool. Compared with CT, MRI is advantageous due to its lack of ionizing radiation, superior soft-tissue contrast resolution, and wider range of acquisition sequences. Several studies have shown PET/MRI to be equivalent to PET/CT in most oncological applications, possibly superior in certain body parts, e.g., head and neck, pelvis, and in certain situations, e.g., cancer recurrence. This review will update the readers on recent advances in PET/MRI technology and review key literature, while highlighting the strengths and weaknesses of PET/MRI in cancer imaging. PMID:26854157

  5. PET/MRI in Oncological Imaging: State of the Art

    Directory of Open Access Journals (Sweden)

    Usman Bashir

    2015-07-01

    Full Text Available Positron emission tomography (PET combined with magnetic resonance imaging (MRI is a hybrid technology which has recently gained interest as a potential cancer imaging tool. Compared with CT, MRI is advantageous due to its lack of ionizing radiation, superior soft-tissue contrast resolution, and wider range of acquisition sequences. Several studies have shown PET/MRI to be equivalent to PET/CT in most oncological applications, possibly superior in certain body parts, e.g., head and neck, pelvis, and in certain situations, e.g., cancer recurrence. This review will update the readers on recent advances in PET/MRI technology and review key literature, while highlighting the strengths and weaknesses of PET/MRI in cancer imaging.

  6. FIRST IMAGES FROM THE FOCUSING OPTICS X-RAY SOLAR IMAGER

    Energy Technology Data Exchange (ETDEWEB)

    Krucker, Säm; Glesener, Lindsay; Turin, Paul; McBride, Stephen; Glaser, David; Fermin, Jose; Lin, Robert [Space Sciences Laboratory, University of California at Berkeley, Berkeley, CA (United States); Christe, Steven [NASA Goddard Space Flight Center, Greenbelt, MD (United States); Ishikawa, Shin-nosuke [National Astronomical Observatory, Mitaka (Japan); Ramsey, Brian; Gubarev, Mikhail; Kilaru, Kiranmayee [NASA Marshall Space Flight Center, Huntsville, AL (United States); Takahashi, Tadayuki; Watanabe, Shin; Saito, Shinya [Institute of Space and Astronautical Science (ISAS)/JAXA, Sagamihara (Japan); Tajima, Hiroyasu [Solar-Terrestial Environment Laboratory, Nagoya University, Nagoya (Japan); Tanaka, Takaaki [Department of Physics, Kyoto University, Kyoto (Japan); White, Stephen [Air Force Research Laboratory, Albuquerque, NM (United States)

    2014-10-01

    The Focusing Optics X-ray Solar Imager (FOXSI) sounding rocket payload flew for the first time on 2012 November 2, producing the first focused images of the Sun above 5 keV. To enable hard X-ray (HXR) imaging spectroscopy via direct focusing, FOXSI makes use of grazing-incidence replicated optics combined with fine-pitch solid-state detectors. On its first flight, FOXSI observed several targets that included active regions, the quiet Sun, and a GOES-class B2.7 microflare. This Letter provides an introduction to the FOXSI instrument and presents its first solar image. These data demonstrate the superiority in sensitivity and dynamic range that is achievable with a direct HXR imager with respect to previous, indirect imaging methods, and illustrate the technological readiness for a spaceborne mission to observe HXRs from solar flares via direct focusing optics.

  7. Assessment of the anatomical relationship between the arcuate eminence and superior semicircular canal by computed tomography

    International Nuclear Information System (INIS)

    Seo, Yoshinobu; Ito, Tamio; Sasaki, Takehiko; Nakagawara, Jyoji; Nakamura, Hirohiko

    2007-01-01

    The anatomical relationship between the arcuate eminence (AE) and the superior semicircular canal (SSC) was examined by computed tomography (CT) in 52 petrous bones of 26 patients. After acquiring volume data by multidetector CT, 1-mm thick oblique bone window images perpendicular to the SSC were obtained from the axial images. The distances between the AE and the SSC, and the SSC and the superior surface of the petrous bone were measured. The AE corresponded exactly with the SSC in only 2/52 petrous bones, and corresponded well in 7/52. The AE was lateral to the SSC in 25/52 cases, medial to the SSC in 6/52 cases, intersected in 3/52 cases, and was indiscernible in 9/52 cases. The distance between the SSC and the petrous surface was 0 mm in 45/52 petrous bones, 1 mm in 5/52, 2 mm in 1/52, and 3 mm in 1/52. The SSC typically does not correspond exactly with the AE, and is generally located just under the surface of the petrous bone. Planning of the middle cranial fossa approach requires location of the SSC by CT. (author)

  8. Dynamic MR imaging of pancreatic cancer

    International Nuclear Information System (INIS)

    Akaki, Shiro; Kohno, Yoshihiro; Gohbara, Hideo

    1994-01-01

    Dynamic MRI was performed on 21 patients with pancreatic duct cell carcinoma. Turbo-FLASH or FLASH3D was performed immediately following rapid bolus injection of gadopentetate dimeglumine, and these FLASH images and conventional spin echo images were evaluated about detectability of the lesion. All images were classified into three groups of detectability of the lesion ; good, fair, and poor. On T 1 weighted image, 23% of cases were 'good' and 48% were evaluated as 'fair'. On the other hand, on dynamic MRI, 62% of cases were 'good' and 33% of cases were evaluated as 'fair'. Both T 2 weighted image and enhanced T 1 weighted image were not useful for depiction of the lesion. Direct comparison between T 1 weighted image and dynamic MRI was also done. In 55% of cases, dynamic MRI was superior to T 1 weighted image and in 40% of cases, dynamic MRI was equal to T 1 weighted image. Thus, dynamic MRI was superior to conventional spin echo images for detection of duct cell carcinoma. In 17 patients of duct cell carcinoma who underwent FLASH3D, contrast/noise ratio (CNR) was calculated before and after injection of gadopentetate dimeglumine. The absolute value of CNR became significantly larger by injection of contrast material. In nine resectable pancreatic carcinomas, two cases of INF α and two cases of medullary type were well depicted. It was concluded that dynamic MRI was useful for evaluation of pancreatic carcinoma. (author)

  9. Superiority in value and the repugnant conclusion

    DEFF Research Database (Denmark)

    Jensen, Karsten Klint

    2007-01-01

    superiority does not amount to a radical value difference at all. I then spell out the consequences of these results for different interpretations of Griffin's suggestion regarding population ethics. None of them comes out very successful, but perhaps they nevertheless retain some interest.......James Griffin has considered a weak form of superiority in value a possible remedy to the Repugnant Conclusion. In this paper, I demonstrate that, in a context where value is additive, this weaker form collapses into a stronger form of superiority. And in a context where value is non-additive, weak...

  10. Superior glenoid inclination and rotator cuff tears.

    Science.gov (United States)

    Chalmers, Peter N; Beck, Lindsay; Granger, Erin; Henninger, Heath; Tashjian, Robert Z

    2018-03-23

    The objectives of this study were to determine whether glenoid inclination (1) could be measured accurately on magnetic resonance imaging (MRI) using computed tomography (CT) as a gold standard, (2) could be measured reliably on MRI, and (3) whether it differed between patients with rotator cuff tears and age-matched controls without evidence of rotator cuff tears or glenohumeral osteoarthritis. In this comparative retrospective radiographic study, we measured glenoid inclination on T1 coronal MRI corrected into the plane of the scapula. We determined accuracy by comparison with CT and inter-rater reliability. We compared glenoid inclination between patients with full-thickness rotator cuff tears and patients aged >50 years without evidence of a rotator cuff tear or glenohumeral arthritis. An a priori power analysis determined adequate power to detect a 2° difference in glenoid inclination. (1) In a validation cohort of 37 patients with MRI and CT, the intraclass correlation coefficient was 0.877, with a mean difference of 0° (95% confidence interval, -1° to 1°). (2) For MRI inclination, the inter-rater intraclass correlation coefficient was 0.911. (3) Superior glenoid inclination was 2° higher (range, 1°-4°, P rotator cuff tear group of 192 patients than in the control cohort of 107 patients. Glenoid inclination can be accurately and reliably measured on MRI. Although superior glenoid inclination is statistically greater in those with rotator cuff tears than in patients of similar age without rotator cuff tears or glenohumeral arthritis, the difference is likely below clinical significance. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  11. Hierarchical layered and semantic-based image segmentation using ergodicity map

    Science.gov (United States)

    Yadegar, Jacob; Liu, Xiaoqing

    2010-04-01

    Image segmentation plays a foundational role in image understanding and computer vision. Although great strides have been made and progress achieved on automatic/semi-automatic image segmentation algorithms, designing a generic, robust, and efficient image segmentation algorithm is still challenging. Human vision is still far superior compared to computer vision, especially in interpreting semantic meanings/objects in images. We present a hierarchical/layered semantic image segmentation algorithm that can automatically and efficiently segment images into hierarchical layered/multi-scaled semantic regions/objects with contextual topological relationships. The proposed algorithm bridges the gap between high-level semantics and low-level visual features/cues (such as color, intensity, edge, etc.) through utilizing a layered/hierarchical ergodicity map, where ergodicity is computed based on a space filling fractal concept and used as a region dissimilarity measurement. The algorithm applies a highly scalable, efficient, and adaptive Peano- Cesaro triangulation/tiling technique to decompose the given image into a set of similar/homogenous regions based on low-level visual cues in a top-down manner. The layered/hierarchical ergodicity map is built through a bottom-up region dissimilarity analysis. The recursive fractal sweep associated with the Peano-Cesaro triangulation provides efficient local multi-resolution refinement to any level of detail. The generated binary decomposition tree also provides efficient neighbor retrieval mechanisms for contextual topological object/region relationship generation. Experiments have been conducted within the maritime image environment where the segmented layered semantic objects include the basic level objects (i.e. sky/land/water) and deeper level objects in the sky/land/water surfaces. Experimental results demonstrate the proposed algorithm has the capability to robustly and efficiently segment images into layered semantic objects

  12. Tree Coding of Bilevel Images

    DEFF Research Database (Denmark)

    Martins, Bo; Forchhammer, Søren

    1998-01-01

    Presently, sequential tree coders are the best general purpose bilevel image coders and the best coders of halftoned images. The current ISO standard, Joint Bilevel Image Experts Group (JBIG), is a good example. A sequential tree coder encodes the data by feeding estimates of conditional...... is one order of magnitude slower than JBIG, obtains excellent and highly robust compression performance. A multipass free tree coding scheme produces superior compression results for all test images. A multipass free template coding scheme produces significantly better results than JBIG for difficult...... images such as halftones. By utilizing randomized subsampling in the template selection, the speed becomes acceptable for practical image coding...

  13. Depth-resolved ballistic imaging in a low-depth-of-field optical Kerr gated imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Yipeng; Tan, Wenjiang, E-mail: tanwenjiang@mail.xjtu.edu.cn; Si, Jinhai; Ren, YuHu; Xu, Shichao; Hou, Xun [Key Laboratory for Physical Electronics and Devices of the Ministry of Education and Shaanxi Key Lab of Information Photonic Technique, School of Electronics and Information Engineering, Xi' an Jiaotong University, Xianning-xilu 28, Xi' an 710049 (China); Tong, Junyi [Departments of Applied Physics, Xi' an University of Technology, Xi' an 710048 (China)

    2016-09-07

    We demonstrate depth-resolved imaging in a ballistic imaging system, in which a heterodyned femtosecond optical Kerr gate is introduced to extract useful imaging photons for detecting an object hidden in turbid media and a compound lens is proposed to ensure both the depth-resolved imaging capability and the long working distance. Two objects of about 15-μm widths hidden in a polystyrene-sphere suspension have been successfully imaged with approximately 600-μm depth resolution. Modulation-transfer-function curves with the object in and away from the object plane have also been measured to confirm the depth-resolved imaging capability of the low-depth-of-field (low-DOF) ballistic imaging system. This imaging approach shows potential for application in research of the internal structure of highly scattering fuel spray.

  14. Dictionary-enhanced imaging cytometry

    Science.gov (United States)

    Orth, Antony; Schaak, Diane; Schonbrun, Ethan

    2017-02-01

    State-of-the-art high-throughput microscopes are now capable of recording image data at a phenomenal rate, imaging entire microscope slides in minutes. In this paper we investigate how a large image set can be used to perform automated cell classification and denoising. To this end, we acquire an image library consisting of over one quarter-million white blood cell (WBC) nuclei together with CD15/CD16 protein expression for each cell. We show that the WBC nucleus images alone can be used to replicate CD expression-based gating, even in the presence of significant imaging noise. We also demonstrate that accurate estimates of white blood cell images can be recovered from extremely noisy images by comparing with a reference dictionary. This has implications for dose-limited imaging when samples belong to a highly restricted class such as a well-studied cell type. Furthermore, large image libraries may endow microscopes with capabilities beyond their hardware specifications in terms of sensitivity and resolution. We call for researchers to crowd source large image libraries of common cell lines to explore this possibility.

  15. Capability Paternalism

    NARCIS (Netherlands)

    Claassen, R.J.G.|info:eu-repo/dai/nl/269266224

    A capability approach prescribes paternalist government actions to the extent that it requires the promotion of specific functionings, instead of the corresponding capabilities. Capability theorists have argued that their theories do not have much of these paternalist implications, since promoting

  16. Study on the usefulness of whole body SPECT coronal image, MIP image in {sup 67}Ga scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Kawamura, Seiji [Kurume Univ., Fukuoka (Japan). Hospital; Ishibashi, Masatoshi; Kurata, Seiji; Morita, Seiichirou; Hayabuchi, Naofumi [Kurume Univ., Fukuoka (Japan). School of Medicine; Fukushima, Shigehiro [Kyushu Inst. of Design, Fukuoka (Japan). Graduate School of Auditory and Visual Communication Sciences; Umezaki, Noriyoshi [Daiichi Coll. of Pharmaceutical Sciences, Fukuoka (Japan)

    2002-05-01

    In this study, we examined the usefulness of whole body coronal images and whole body cine display MIP images (CMIP) upon which image processing was carried out after whole body SPECT in comparison to the usefulness of whole body images (WB/SC) compensated by scattered radiation in tumor/inflammation scintigraphy with {sup 67}Ga-citrate ({sup 67}Ga). Image interpretation was performed for the 120 patients with confirmed diagnoses, and the accuracy of their diagnoses was studied by three nuclear medical physicians and two clinical radiological technologists by means of sensitivity, specificity and ROC analysis. The resultant data show that sensitivity, specificity, accuracy and the area under the ROC curve Az in the WB/SC were approximately 65%, 86%, 74% and 0.724, respectively, whereas sensitivity, specificity, accuracy and Az of the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method were approximately 93%, 95%, 94% and 0.860, respectively. Furthermore, coronal images reconstructed by the OS-EM method tended to be superior to those produced by the FBP method in both diagnostic accuracy and ROC analysis. In conclusion, the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method was shown to be superior in diagnostic accuracy and ROC analysis. Our data suggest that whole body SPECT is an excellent technique as an alternative to WB/SC. (author)

  17. Imaging of spine injuries

    International Nuclear Information System (INIS)

    Lomoschitz, F. . e-mai: friedrich.lomoschitz@univie.ac.at

    2001-01-01

    Spinal trauma requires a prompt and detailed diagnosis for estimating the prognosis and installing proper therapy. Conventional radiograms are the first imaging modality in most cases. In the cervical and the lumbar spine, a CT has to be performed in patients with polytrauma and a higher risk of complications or with signs of instability. Especially for imaging the cervicocranium, multiplanar reformations in sagittal and coronal planes are necessary. For fractures of the thoracic spine, MR imaging is superior to CT because of the better detection of associated neurologic complications. (author)

  18. Development of an MR-compatible hand exoskeleton that is capable of providing interactive robotic rehabilitation during fMRI imaging.

    Science.gov (United States)

    Kim, Sangjoon J; Kim, Yeongjin; Lee, Hyosang; Ghasemlou, Pouya; Kim, Jung

    2018-02-01

    Following advances in robotic rehabilitation, there have been many efforts to investigate the recovery process and effectiveness of robotic rehabilitation procedures through monitoring the activation status of the brain. This work presents the development of a two degree-of-freedom (DoF) magnetic resonance (MR)-compatible hand device that can perform robotic rehabilitation procedures inside an fMRI scanner. The device is capable of providing real-time monitoring of the joint angle, angular velocity, and joint force produced by the metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joints of four fingers. For force measurement, a custom reflective optical force sensor was developed and characterized in terms of accuracy error, hysteresis, and repeatability in the MR environment. The proposed device consists of two non-magnetic ultrasonic motors to provide assistive and resistive forces to the MCP and PIP joints. With actuation and sensing capabilities, both non-voluntary-passive movements and active-voluntary movements can be implemented. The MR compatibility of the device was verified via the analysis of the signal-to-noise ratio (SNR) of MR images of phantoms. SNR drops of 0.25, 2.94, and 11.82% were observed when the device was present but not activated, when only the custom force sensor was activated, and when both the custom force sensor and actuators were activated, respectively.

  19. Superior Hiking Trail Facilities

    Data.gov (United States)

    Minnesota Department of Natural Resources — Superior Hiking Trail main trail, spurs, and camp spurs for completed trail throughout Cook, Lake, St. Louis and Carlton counties. These data were collected with...

  20. Magnetic nanosensor particles in luminescence upconversion capability.

    Science.gov (United States)

    Wilhelm, Stefan; Hirsch, Thomas; Scheucher, Elisabeth; Mayr, Torsten; Wolfbeis, Otto S

    2011-09-05

    Nanoparticles (NPs) exhibit interesting size-dependent electrical, optical, magnetic, and chemical properties that cannot be observed in their bulk counterparts. The synthesis of NPs (i.e., crystalline particles ranging in size from 1 to 100 nm) has been intensely studied in the past decades. Magnetic nanoparticles (MNPs) form a particularly attractive class of NPs and have found numerous applications such as in magnetic resonance imaging to visualize cancer, cardiovascular, neurological and other diseases. Other uses include drug targeting, tissue imaging, magnetic immobilization, hyperthermia, and magnetic resonance imaging. MNPs, due to their magnetic properties, can be easily separated from (often complex) matrices and manipulated by applying external magnetic field. Near-infrared to visible upconversion luminescent nanoparticles (UCLNPs) form another type of unusual nanoparticles. They are capable of emitting visible light upon NIR light excitation. Lanthanide-doped (Yb, Er) hexagonal NaYF₄ UCLNPs are the most efficient upconversion phosphors known up to now. The use of UCLNPs for in vitro imaging of cancer cells and in vivo imaging in tissues has been demonstrated. UCLNPs show great potential as a new class of luminophores for biological, biomedical, and sensor applications. We are reporting here on our first results on the combination of MNP and UCLNP technology within an ongoing project supported by the DFG and the FWF (Austria).

  1. Quantitative luminescence imaging system

    Science.gov (United States)

    Erwin, David N.; Kiel, Johnathan L.; Batishko, Charles R.; Stahl, Kurt A.

    1990-01-01

    The QLIS images and quantifies low-level chemiluminescent reactions in an electromagnetic field. It is capable of real time nonperturbing measurement and simultaneous recording of many biochemical and chemical reactions such as luminescent immunoassays or enzyme assays. The system comprises image transfer optics, a low-light level digitizing camera with image intensifying microchannel plates, an image process or, and a control computer. The image transfer optics may be a fiber image guide with a bend, or a microscope, to take the light outside of the RF field. Output of the camera is transformed into a localized rate of cumulative digitalized data or enhanced video display or hard-copy images. The system may be used as a luminescent microdosimetry device for radiofrequency or microwave radiation, as a thermal dosimeter, or in the dosimetry of ultra-sound (sonoluminescence) or ionizing radiation. It provides a near-real-time system capable of measuring the extremely low light levels from luminescent reactions in electromagnetic fields in the areas of chemiluminescence assays and thermal microdosimetry, and is capable of near-real-time imaging of the sample to allow spatial distribution analysis of the reaction. It can be used to instrument three distinctly different irradiation configurations, comprising (1) RF waveguide irradiation of a small Petri-dish-shaped sample cell, (2) RF irradiation of samples in a microscope for the microscopie imaging and measurement, and (3) RF irradiation of small to human body-sized samples in an anechoic chamber.

  2. Automated Cart with VIS/NIR Hyperspectral Reflectance and Fluorescence Imaging Capabilities

    Directory of Open Access Journals (Sweden)

    Alan M. Lefcourt

    2016-12-01

    Full Text Available A system to take high-resolution Visible/Near Infra-Red (VIS/NIR hyperspectral reflectance and fluorescence images in outdoor fields using ambient lighting or a pulsed laser (355 nm, respectively, for illumination purposes was designed, built, and tested. Components of the system include a semi-autonomous cart, a gated-intensified camera, a spectral adapter, a frequency-triple Nd:YAG (Neodymium-doped Yttrium Aluminium Garnet laser, and optics to convert the Gaussian laser beam into a line-illumination source. The front wheels of the cart are independently powered by stepper motors that support stepping or continuous motion. When stepping, a spreadsheet is used to program parameters of image sets to be acquired at each step. For example, the spreadsheet can be used to set delays before the start of image acquisitions, acquisition times, and laser attenuation. One possible use of this functionality would be to establish acquisition parameters to facilitate the measurement of fluorescence decay-curve characteristics. The laser and camera are mounted on an aluminum plate that allows the optics to be calibrated in a laboratory setting and then moved to the cart. The system was validated by acquiring images of fluorescence responses of spinach leaves and dairy manure.

  3. Clinical evaluation of myocardial perfusion imaging with 99mTc-CPI

    International Nuclear Information System (INIS)

    Liu Xiujie

    1988-01-01

    10 normal subjects and 55 cases of patients with heart diseases were studied with 99m Tc-CPI myocardial perfusion imaging. The 99m Tc-CPI myocarbial imaging is superior to 99m Tc-TBI, because the uptake of 99m Tc-CPI in both lung and liver is lower. The imaging quality of 99m Tc-CPI is nearly as good as that of 201 Tl. 16 patients had both 99m Tc-CPI myocardial imaging and coronary artery angiography. The sensitivity of 99m Tc-CPI myocardial imaging for detecting coronary artery disease (CAD) was 92%, whereas the sensitivity of ECG was 84.6%. 99m Tc-CPI myocardial tomography was obtained in 17 patients using Toshiba 90B SPECT system. The imaging quality of myocardial tomography using 99m Tc-CPI is very good and superior to planar imaging for detecting myocardial infarction

  4. Three-dimensional reconstruction of brain surface anatomy: technique comparison between flash and diffusion-weighted imaging

    International Nuclear Information System (INIS)

    Sun Jianzhong; Wang Zhikang; Gong Xiangyang

    2006-01-01

    Objective: To compare two methods 3D flash and diffusion-weighted images (DWI) in reconstructing the brain surface anatomy, and to evaluate their displaying ability, advantages, limitations and clinical application. Methods: Thrity normal cases were prospectively examined with 3D flash sequence and echo-planar DWI. Three-dimensional images were acquired with volume-rendering on workstation. Brain surface structures were evaluated and scored by a group of doctors. Results: Main structures of brain surface were clearly displayed on three-dimensional images based on 3D flash sequence. Average scores were all above 2.50. For images based on DWI, precentral gyrus, postcentral gyrus, superior parietal lobule, superior frontal gyrus, precentral sulcus, central sulcus, postcentral sulcus, intraparietal sulcus and superior frontal sulcus were best shown with average scores between 2.60-2.75, However, supramarginal gyrus, angular gyrus, middle frontal gyrus, inferior frontal gyrus, superior temporal gyrus, lateral sulcus, inferior frontal sulcus could not be well shown, with average scores between 1.67-2.48. Middle temporal gyrus, inferior temporal gyrus, superior temporal sulcus and inferior temporal sulcus can only get scores from 0.88 to 1.27. Scores of images based on 3D flash were much higher than that based on DWI with distinct differentiations, P values were all below 0.01. Conclusion: Three-dimensional images based on 3D flash can really display brain surface structures. It is very useful for anatomic researches. Three-dimensional reconstruction of brain surface based on DWI is a worthy technique to display brain surface anatomy, especially for frontal and parietal structures. (authors)

  5. Small bowel volvulus in pregnancy with associated superior mesenteric artery occlusion.

    Science.gov (United States)

    Esterson, Yonah B; Villani, Robert; Dela Cruz, Ronald A; Friedman, Barak; Grimaldi, Gregory M

    Here we report the case of a pregnant 28-year-old who presented with acute upper abdominal pain. CT demonstrated midgut volvulus with short segment occlusion of the superior mesenteric artery (SMA). Emergent detorsion of the small bowel was performed, at which time underlying intestinal malrotation was discovered. Following detorsion, the SMA had a bounding pulse and did not require thrombectomy or revascularization. Fewer than 25 cases of midgut volvulus during pregnancy have been reported over the past 20years. To our knowledge, this is the first report of maternal midgut volvulus in which imaging captures the resultant occlusion of the SMA. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Insertion of the human sodium iodide symporter to facilitate deep tissue imaging does not alter oncolytic or replication capability of a novel vaccinia virus

    Directory of Open Access Journals (Sweden)

    Mittra Arjun

    2011-03-01

    Full Text Available Abstract Introduction Oncolytic viruses show promise for treating cancer. However, to assess therapeutic efficacy and potential toxicity, a noninvasive imaging modality is needed. This study aimed to determine if insertion of the human sodium iodide symporter (hNIS cDNA as a marker for non-invasive imaging of virotherapy alters the replication and oncolytic capability of a novel vaccinia virus, GLV-1h153. Methods GLV-1h153 was modified from parental vaccinia virus GLV-1h68 to carry hNIS via homologous recombination. GLV-1h153 was tested against human pancreatic cancer cell line PANC-1 for replication via viral plaque assays and flow cytometry. Expression and transportation of hNIS in infected cells was evaluated using Westernblot and immunofluorescence. Intracellular uptake of radioiodide was assessed using radiouptake assays. Viral cytotoxicity and tumor regression of treated PANC-1tumor xenografts in nude mice was also determined. Finally, tumor radiouptake in xenografts was assessed via positron emission tomography (PET utilizing carrier-free 124I radiotracer. Results GLV-1h153 infected, replicated within, and killed PANC-1 cells as efficiently as GLV-1h68. GLV-1h153 provided dose-dependent levels of hNIS expression in infected cells. Immunofluorescence detected transport of the protein to the cell membrane prior to cell lysis, enhancing hNIS-specific radiouptake (P In vivo, GLV-1h153 was as safe and effective as GLV-1h68 in regressing pancreatic cancer xenografts (P 124I-PET. Conclusion Insertion of the hNIS gene does not hinder replication or oncolytic capability of GLV-1h153, rendering this novel virus a promising new candidate for the noninvasive imaging and tracking of oncolytic viral therapy.

  7. Cardiac imaging in adults

    International Nuclear Information System (INIS)

    Jaffe, C.C.

    1987-01-01

    This book approaches adult cardiac disease from the correlative imaging perspective. It includes chest X-rays and angiographs, 2-dimensional echocardiograms with explanatory diagrams for clarity, plus details on digital radiology, nuclear medicine techniques, CT and MRI. It also covers the normal heart, valvular heart disease, myocardial disease, pericardial disease, bacterial endocarditis, aortic aneurysm, cardiac tumors, and congenital heart disease of the adult. It points out those aspects where one imaging technique has significant superiority

  8. Cardiac imaging in adults

    Energy Technology Data Exchange (ETDEWEB)

    Jaffe, C.C.

    1987-01-01

    This book approaches adult cardiac disease from the correlative imaging perspective. It includes chest X-rays and angiographs, 2-dimensional echocardiograms with explanatory diagrams for clarity, plus details on digital radiology, nuclear medicine techniques, CT and MRI. It also covers the normal heart, valvular heart disease, myocardial disease, pericardial disease, bacterial endocarditis, aortic aneurysm, cardiac tumors, and congenital heart disease of the adult. It points out those aspects where one imaging technique has significant superiority.

  9. The upgraded cold neutron triple-axis spectrometer FLEXX – enhanced capabilities by new instrumental options

    Directory of Open Access Journals (Sweden)

    Habicht Klaus

    2015-01-01

    Full Text Available The upgrade of the cold neutron triple axis spectrometer FLEXX, a work-horse instrument for inelastic neutron scattering matching the sample environment capabilities at Helmholtz-Zentrum Berlin, has been successfully accomplished. Experiments confirmed an order of magnitude gain in flux now allowing for intensity demanding options to be fully exploited at FLEXX. In this article, we describe the layout and design of two newly available FLEXX instrument options in detail. The new Heusler analyzer gives an increase of the detected polarized neutron flux due to its superior focusing properties, significantly improving the feasibility of future polarized and neutron resonance spin echo experiments. The MultiFLEXX option provides simultaneous access to large regions in wavevector and energy space for inelastic excitations thus adding mapping capabilities to the spectrometer.

  10. Microscopy image segmentation tool: Robust image data analysis

    Energy Technology Data Exchange (ETDEWEB)

    Valmianski, Ilya, E-mail: ivalmian@ucsd.edu; Monton, Carlos; Schuller, Ivan K. [Department of Physics and Center for Advanced Nanoscience, University of California San Diego, 9500 Gilman Drive, La Jolla, California 92093 (United States)

    2014-03-15

    We present a software package called Microscopy Image Segmentation Tool (MIST). MIST is designed for analysis of microscopy images which contain large collections of small regions of interest (ROIs). Originally developed for analysis of porous anodic alumina scanning electron images, MIST capabilities have been expanded to allow use in a large variety of problems including analysis of biological tissue, inorganic and organic film grain structure, as well as nano- and meso-scopic structures. MIST provides a robust segmentation algorithm for the ROIs, includes many useful analysis capabilities, and is highly flexible allowing incorporation of specialized user developed analysis. We describe the unique advantages MIST has over existing analysis software. In addition, we present a number of diverse applications to scanning electron microscopy, atomic force microscopy, magnetic force microscopy, scanning tunneling microscopy, and fluorescent confocal laser scanning microscopy.

  11. Microscopy image segmentation tool: Robust image data analysis

    Science.gov (United States)

    Valmianski, Ilya; Monton, Carlos; Schuller, Ivan K.

    2014-03-01

    We present a software package called Microscopy Image Segmentation Tool (MIST). MIST is designed for analysis of microscopy images which contain large collections of small regions of interest (ROIs). Originally developed for analysis of porous anodic alumina scanning electron images, MIST capabilities have been expanded to allow use in a large variety of problems including analysis of biological tissue, inorganic and organic film grain structure, as well as nano- and meso-scopic structures. MIST provides a robust segmentation algorithm for the ROIs, includes many useful analysis capabilities, and is highly flexible allowing incorporation of specialized user developed analysis. We describe the unique advantages MIST has over existing analysis software. In addition, we present a number of diverse applications to scanning electron microscopy, atomic force microscopy, magnetic force microscopy, scanning tunneling microscopy, and fluorescent confocal laser scanning microscopy.

  12. Microscopy image segmentation tool: Robust image data analysis

    International Nuclear Information System (INIS)

    Valmianski, Ilya; Monton, Carlos; Schuller, Ivan K.

    2014-01-01

    We present a software package called Microscopy Image Segmentation Tool (MIST). MIST is designed for analysis of microscopy images which contain large collections of small regions of interest (ROIs). Originally developed for analysis of porous anodic alumina scanning electron images, MIST capabilities have been expanded to allow use in a large variety of problems including analysis of biological tissue, inorganic and organic film grain structure, as well as nano- and meso-scopic structures. MIST provides a robust segmentation algorithm for the ROIs, includes many useful analysis capabilities, and is highly flexible allowing incorporation of specialized user developed analysis. We describe the unique advantages MIST has over existing analysis software. In addition, we present a number of diverse applications to scanning electron microscopy, atomic force microscopy, magnetic force microscopy, scanning tunneling microscopy, and fluorescent confocal laser scanning microscopy

  13. Image-Guided Cancer Nanomedicine

    Directory of Open Access Journals (Sweden)

    Dong-Hyun Kim

    2018-01-01

    Full Text Available Multifunctional nanoparticles with superior imaging properties and therapeutic effects have been extensively developed for the nanomedicine. However, tumor-intrinsic barriers and tumor heterogeneity have resulted in low in vivo therapeutic efficacy. The poor in vivo targeting efficiency in passive and active targeting of nano-therapeutics along with the toxicity of nanoparticles has been a major problem in nanomedicine. Recently, image-guided nanomedicine, which can deliver nanoparticles locally using non-invasive imaging and interventional oncology techniques, has been paid attention as a new opportunity of nanomedicine. This short review will discuss the existing challenges in nanomedicine and describe the prospects for future image-guided nanomedicine.

  14. The CT appearance of the superior intercostal veins

    International Nuclear Information System (INIS)

    Lund, G.

    1982-01-01

    The CT appearance of the superior intercostal veins is described. The veins are more frequently seen on the right side. The right superior intercostal vein should not be misinterpreted as a paraspinal mass when it is large or bulges into the contour of the right lung. A case of stenosis of the left brachiocephalic vein is shown, where the left superior intercostal vein serves as a collateral. (orig.)

  15. Applications of digital image analysis capability in Idaho

    Science.gov (United States)

    Johnson, K. A.

    1981-01-01

    The use of digital image analysis of LANDSAT imagery in water resource assessment is discussed. The data processing systems employed are described. The determination of urban land use conversion of agricultural land in two southwestern Idaho counties involving estimation and mapping of crop types and of irrigated land is described. The system was also applied to an inventory of irrigated cropland in the Snake River basin and establishment of a digital irrigation water source/service area data base for the basin. Application of the system to a determination of irrigation development in the Big Lost River basin as part of a hydrologic survey of the basin is also described.

  16. Building EOS capability for Malaysia - the options

    Science.gov (United States)

    Subari, M. D.; Hassan, A.

    2014-06-01

    Earth observation satellite (EOS) is currently a major tool to monitor earth dynamics and increase human understanding of earth surface process. Since the early 80s, Malaysia has been using EOS images for various applications, such as weather forecasting, land use mapping, agriculture, environment monitoring and others. Until now, all EOS images were obtained from foreign satellite systems. Realising on the strategic need of having its own capability, Malaysia embarked into EOS development programs in the early 90s. Starting with TiungSAT-1, a micro-satellite carrying small camera, then followed by RazakSAT, a small satellite carrying 2.5 m panchromatic (PAN) medium-aperture-camera, the current satellite program development, the RazakSAT-2, designed to carry a 1.0 m high resolution PAN and 4.0m multi-spectral camera, would become a strategic initiative of the government in developing and accelerating the nation's capability in the area of satellite technology and its application. Would this effort continue until all needs of the remote sensing community being fulfilled by its own EOS? This paper will analyze the intention of the Malaysian government through its National Space Policy and other related policy documents, and proposes some policy options on this. Key factors to be considered are specific data need of the EOS community, data availability and the more subjective political motivations such as national pride.

  17. Microwave imaging

    CERN Document Server

    Pastorino, Matteo

    2010-01-01

    An introduction to the most relevant theoretical and algorithmic aspects of modern microwave imaging approaches Microwave imaging-a technique used in sensing a given scene by means of interrogating microwaves-has recently proven its usefulness in providing excellent diagnostic capabilities in several areas, including civil and industrial engineering, nondestructive testing and evaluation, geophysical prospecting, and biomedical engineering. Microwave Imaging offers comprehensive descriptions of the most important techniques so far proposed for short-range microwave imaging-in

  18. Dynamic capabilities, Marketing Capability and Organizational Performance

    Directory of Open Access Journals (Sweden)

    Adriana Roseli Wünsch Takahashi

    2017-01-01

    Full Text Available The goal of the study is to investigate the influence of dynamic capabilities on organizational performance and the role of marketing capabilities as a mediator in this relationship in the context of private HEIs in Brazil. As a research method we carried out a survey with 316 IES and data analysis was operationalized with the technique of structural equation modeling. The results indicate that the dynamic capabilities have influence on organizational performance only when mediated by marketing ability. The marketing capability has an important role in the survival, growth and renewal on educational services offerings for HEIs in private sector, and consequently in organizational performance. It is also demonstrated that mediated relationship is more intense for HEI with up to 3,000 students and other organizational profile variables such as amount of courses, the constitution, the type of institution and type of education do not significantly alter the results.

  19. Superior orbital fissure syndrome in herpes zoster ophthalmicus.

    LENUS (Irish Health Repository)

    Kirwan, R P

    2012-02-01

    AIM: To report a case of superior orbital fissure syndrome (SOFS) in a patient with herpes zoster ophthalmicus (HZO). MATERIALS AND METHODS: A case report. RESULTS: A 71-year-old male with HZO presented acutely to accident and emergency complaining of right vision loss, double vision and drowsiness. The right visual acuity was counting fingers. There was no relative afferent pupillary defect. He had interstitial keratitis, ptosis, proptosis and total ophthalmoplaegia. The signs indicated HZO complicated by SOFS. Brain imaging and lumbar puncture confirmed the diagnosis of varicella zoster encephalitis. Systemic acyclovir and prednisolone led to recovery of visual acuity and ocular motility in addition to resolution of his proptosis and ptosis. CONCLUSION: SOFS is a rare complication of herpes zoster infection. With the appropriate treatment and follow-up, patients may be reassured that recovery of their visual acuity and ocular motility will occur.

  20. 75 FR 28542 - Superior Resource Advisory Committee

    Science.gov (United States)

    2010-05-21

    ... Self-Determination Act (Pub. L. 110-343) and in compliance with the Federal Advisory Committee Act. The purpose of the meeting is to orient the new Superior Resource Advisory Committee members on their roles... following business will be conducted: Overview of the roles and responsibilities of the Superior Resource...

  1. Three-dimensional constructive interference in steady-state magnetic resonance imaging in syringomyelia: advantages over conventional imaging.

    Science.gov (United States)

    Roser, Florian; Ebner, Florian H; Danz, Søren; Riether, Felix; Ritz, Rainer; Dietz, Klaus; Naegele, Thomas; Tatagiba, Marcos S

    2008-05-01

    Neuroradiology has become indispensable in detecting the pathophysiology in syringomyelia. Constructive interference in steady-state (CISS) magnetic resonance (MR) imaging can provide superior contrast at the sub-arachnoid tissue borders. As this region is critical in preoperative evaluation, the authors hypothesized that CISS imaging would provide superior assessment of syrinx pathology and surgical planning. Based on records collected from a database of 130 patients with syringomyelia treated at the authors' institution, 59 patients were prospectively evaluated with complete neuroradiological examinations. In addition to routine acquisitions with FLAIR, T1- and T2-weighted, and contrast-enhanced MR imaging series, the authors obtained sagittal cardiac-gated sequences to visualize cerebrospinal fluid (CSF) pulsations and axial 3D CISS MR sequences to detect focal arachnoid webs. Statistical qualitative and quantitative evaluations of spinal cord/CSF contrast, spinal cord/CSF delineation, motion artifacts, and artifacts induced by pulsatile CSF flow were performed. The 3D CISS MR sequences demonstrated a contrast-to-noise ratio significantly better than any other routine imaging sequence (p CSF flow voids. Constructive interference in steady-state MR imaging enables the neurosurgeon to accurately identify cases requiring decompression for obstructed CSF. Motion artifacts can be eliminated with technical variations.

  2. Superiority of Bessel function over Zernicke polynomial as base ...

    Indian Academy of Sciences (India)

    Abstract. Here we describe the superiority of Bessel function as base function for radial expan- sion over Zernicke polynomial in the tomographic reconstruction technique. The causes for the superiority have been described in detail. The superiority has been shown both with simulated data for Kadomtsev's model for ...

  3. Thermal Infrared Imaging of Exoplanets

    International Nuclear Information System (INIS)

    Apai, Daniel

    2009-01-01

    High-contrast imaging remains the only way to search for and study weakly-irradiated giant exoplanets. We review here in brief a new high-contrast imaging technique that operates in the 3-5 μm window and show the exquisite sensitivity that can be reached using this technique. The two key advantages of the L-band high-contrast imaging are the superior image quality and the 2-to 4-magnitude gain in sensitivity provided by the red color of giant planets. Most excitingly, this method can be applied to constrain the yet-unexplored giant planet population at radii between 3 and 30 AU.

  4. Development of a Vision-Based Situational Awareness Capability for Unmanned Surface Vessels

    Science.gov (United States)

    2017-09-01

    camera), which is similar to the movement of the ship in the electro-optics (EO) video imagery. An image of the model representing the ship with a...with both color video imagery and infrared video imagery, and the results obtained from processing the images demonstrated the viability of using this...situational awareness capability, which is required to achieve autonomous navigation. The algorithm was tested with both color video imagery and infrared

  5. Bathymetry of Lake Superior

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Bathymetry of Lake Superior has been compiled as a component of a NOAA project to rescue Great Lakes lake floor geological and geophysical data and make it more...

  6. Evaluation of image-guided helical tomotherapy for the retreatment of spinal metastasis

    International Nuclear Information System (INIS)

    Mahan, Stephen L.; Ramsey, Chester R.; Scaperoth, Daniel D.; Chase, Daniel J.; Byrne, Thomas E.

    2005-01-01

    Introduction: Patients with vertebral metastasis that receive radiation therapy are typically treated to the spinal cord tolerance dose. As such, it is difficult to successfully deliver a second course of radiation therapy for patients with overlapping treatment volumes. In this study, an image-guided helical tomotherapy system was evaluated for the retreatment of previously irradiated vertebral metastasis. Methods and Materials: Helical tomotherapy dose gradients and maximum cord doses were measured in a cylindrical phantom for geometric test cases with separations between the planning target volume (PTV) and the spinal cord organ at risk (OAR) of 2 mm, 4 mm, 6 mm, 8 mm, and 10 mm. Megavoltage computed tomography (CT) images were examined for their ability to localize spinal anatomy for positioning purposes by repeat imaging of the cervical spine in an anthropomorphic phantom. In addition to the phantom studies, 8 patients with cord compressions that had received previous radiation therapy were retreated to a mean dose of 28 Gy using conventional fractionation. Results and Discussion: Megavoltage CT images were capable of positioning an anthropomorphic phantom to within ±1.2 mm (2σ) superior-inferiorly and within ±0.6 mm (2σ) anterior-posteriorly and laterally. Dose gradients of 10% per mm were measured in phantom while PTV uniformity indices of less than 11% were maintained. The calculated maximum cord dose was 25% of the prescribed dose for a 10-mm PTV-to-OAR separation and 71% of the prescribed dose for a PTV-to-OAR separation of 2 mm. Eight patients total have been treated without radiation-induced myelopathy or any other adverse effects from treatment. Conclusions: A technique has been evaluated for the retreatment of vertebral metastasis using image-guided helical tomotherapy. Phantom and patient studies indicated that a tomotherapy system is capable of delivering dose gradients of 10% per mm and positioning the patient within 1.2 mm without the use of

  7. Image-Problem?

    DEFF Research Database (Denmark)

    Leach, Dawn; Kacunko, Slavko; Bader, Lena

    The attention of German speaking discourse is more than ever before driven to conceptualise the picture/image as medium, and performance. Studies in art, media, theatre, performance and picture theory guided by these efforts all vie for superiority. ¿eir manoeuvres seem for the outsider motivated...... the context of the current discussion of the picture/image science. ¿e theoretical, practical, and technical discourse on media arts’ assumptions, effects, and possibilities still take place at the margins of media festivals and media exhibitions, hard- and so¿ware fairs, and particularly within the framework...... arts’ practice, theory, and history from university contexts and brought together competent media experts, junior research staff and the interested public. The present collection of texts begins with Dawn Leach’s brief discussion of the image and text issue, image differences, and systematisation...

  8. Near-infrared fluorescence imaging with a mobile phone (Conference Presentation)

    Science.gov (United States)

    Ghassemi, Pejhman; Wang, Bohan; Wang, Jianting; Wang, Quanzeng; Chen, Yu; Pfefer, T. Joshua

    2017-03-01

    Mobile phone cameras employ sensors with near-infrared (NIR) sensitivity, yet this capability has not been exploited for biomedical purposes. Removing the IR-blocking filter from a phone-based camera opens the door to a wide range of techniques and applications for inexpensive, point-of-care biophotonic imaging and sensing. This study provides proof of principle for one of these modalities - phone-based NIR fluorescence imaging. An imaging system was assembled using a 780 nm light source along with excitation and emission filters with 800 nm and 825 nm cut-off wavelengths, respectively. Indocyanine green (ICG) was used as an NIR fluorescence contrast agent in an ex vivo rodent model, a resolution test target and a 3D-printed, tissue-simulating vascular phantom. Raw and processed images for red, green and blue pixel channels were analyzed for quantitative evaluation of fundamental performance characteristics including spectral sensitivity, detection linearity and spatial resolution. Mobile phone results were compared with a scientific CCD. The spatial resolution of CCD system was consistently superior to the phone, and green phone camera pixels showed better resolution than blue or green channels. The CCD exhibited similar sensitivity as processed red and blue pixels channels, yet a greater degree of detection linearity. Raw phone pixel data showed lower sensitivity but greater linearity than processed data. Overall, both qualitative and quantitative results provided strong evidence of the potential of phone-based NIR imaging, which may lead to a wide range of applications from cancer detection to glucose sensing.

  9. Magnetization transfer contrast on gradient echo MR imaging of the temporomandibular joint

    International Nuclear Information System (INIS)

    Niitsu, M.; Hirohata, H.; Yoshioka, H.; Anno, I.; Campeau, N.G.; Itai, Y.

    1995-01-01

    Thirty-nine temporomandibular joints (TMJ) from 20 patients with suspected internal derangements were imaged by a 1.5 T MR imager. The on-resonance binomial magnetization transfer contrast (MTC) pulse was applied to gradient echo images with a dual receiver coil (9 s/section). With the use of an opening device, a series of sequential images were obtained at increments of mouth opening and closing. The tissue signal intensities with (Ms) and without (Mo) MTC were measured and subjective image analysis was performed. Compared with the standard images, MTC technique provided selective signal suppression of disks. The average of Ms/Mo ratio of the disks (0.56) was lower than that of the retrodiskal pad (0.79) and of the effusion (0.89). With MTC technique, fluid conspicuity was superior to standard image. However, no significant superiority was found in disk definition subjectively. (orig.)

  10. Sandia Laboratories technical capabilities. Auxiliary capabilities: environmental health information science

    International Nuclear Information System (INIS)

    1975-09-01

    Sandia Laboratories is an engineering laboratory in which research, development, testing, and evaluation capabilities are integrated by program management for the generation of advanced designs. In fulfilling its primary responsibility to ERDA, Sandia Laboratories has acquired extensive research and development capabilities. The purpose of this series of documents is to catalog the many technical capabilities of the Laboratories. After the listing of capabilities, supporting information is provided in the form of highlights, which show applications. This document deals with auxiliary capabilities, in particular, environmental health and information science. (11 figures, 1 table) (RWR)

  11. MR imaging of extrapyramidal disorders

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Ken; Kinoshita, Masao; Iwasaki, Yasuo; Shiojima, Toshiya (Toho Univ., Tokyo (Japan). Ohashi Hospital); Sunahara, Nobuhiko

    1992-04-01

    Magnetic resonance imaging (MRI) was performed in a total of 35 patients with extrapyramidal disorder, including Parkinson's disease (n=15), multiple system atrophy (MSA, n=12), progressive supranuclear palsy (PSP, n=5), and dentatoruburopallidoluysian atrophy (DRPLA, n=3). MR images 5-10 mm in thickness were obtained in both axial and coronal sections. In all patients with Parkinson's disease, there was non-specific age-related cortical atrophy on T[sub 1]-weighted images. T[sub 2]-weighted imaging showed not only putaminal hypointensity, but also linear hyperintensity in the lateral part of putamen. However, these MR findings were not considered pathognomonic. All MSA patients showed atrophy of the brainstem and cerbellum on T[sub 1]-weighted images. Both proton density and T[sub 2]-weighted image showed increased signal intensity in the pontine transverse fibers between the tegmentum and basis pontis. These findings were correlated with atrophy degree of brainstem and middle cerebellar peduncles. It was also difficult to distinguish hyperintesnity in red nuclei from substantia nigra on T[sub 2]-weighted images. Severe atrophy of tegmentum of midbrain and high signal intensity area in the periaqueductal zone were found in all PSP patients on proton density images. Distinction between low signal areas of red nuclei and substantia nigra were obscure in these patients. In some cases of MSA and PSP, small oval hypointensity signals were also found in the superior colliculi. All DRPLA patients had cortical and cerebellar atrophy, but normal brainstem on T[sub 1]-weighted images. On proton density and T[sub 2]-weighted images, hyperintensity signal areas were found in the superior cerebellar peduncles. There was signal restoration in the dentate nuclei on T[sub 2]-weighted images. There was no specific change of signal intensity in the red nuclei, substantia nigra, basal ganglia, and cerebral white matter. (N.K.).

  12. MR imaging of extrapyramidal disorders

    International Nuclear Information System (INIS)

    Ikeda, Ken; Kinoshita, Masao; Iwasaki, Yasuo; Shiojima, Toshiya; Sunahara, Nobuhiko.

    1992-01-01

    Magnetic resonance imaging (MRI) was performed in a total of 35 patients with extrapyramidal disorder, including Parkinson's disease (n=15), multiple system atrophy (MSA, n=12), progressive supranuclear palsy (PSP, n=5), and dentatoruburopallidoluysian atrophy (DRPLA, n=3). MR images 5-10 mm in thickness were obtained in both axial and coronal sections. In all patients with Parkinson's disease, there was non-specific age-related cortical atrophy on T 1 -weighted images. T 2 -weighted imaging showed not only putaminal hypointensity, but also linear hyperintensity in the lateral part of putamen. However, these MR findings were not considered pathognomonic. All MSA patients showed atrophy of the brainstem and cerbellum on T 1 -weighted images. Both proton density and T 2 -weighted image showed increased signal intensity in the pontine transverse fibers between the tegmentum and basis pontis. These findings were correlated with atrophy degree of brainstem and middle cerebellar peduncles. It was also difficult to distinguish hyperintesnity in red nuclei from substantia nigra on T 2 -weighted images. Severe atrophy of tegmentum of midbrain and high signal intensity area in the periaqueductal zone were found in all PSP patients on proton density images. Distinction between low signal areas of red nuclei and substantia nigra were obscure in these patients. In some cases of MSA and PSP, small oval hypointensity signals were also found in the superior colliculi. All DRPLA patients had cortical and cerebellar atrophy, but normal brainstem on T 1 -weighted images. On proton density and T 2 -weighted images, hyperintensity signal areas were found in the superior cerebellar peduncles. There was signal restoration in the dentate nuclei on T 2 -weighted images. There was no specific change of signal intensity in the red nuclei, substantia nigra, basal ganglia, and cerebral white matter. (N.K.)

  13. MR imaging of extrapyramidal disorders

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Ken; Kinoshita, Masao; Iwasaki, Yasuo; Shiojima, Toshiya [Toho Univ., Tokyo (Japan). Ohashi Hospital; Sunahara, Nobuhiko

    1992-04-01

    Magnetic resonance imaging (MRI) was performed in a total of 35 patients with extrapyramidal disorder, including Parkinson's disease (n=15), multiple system atrophy (MSA, n=12), progressive supranuclear palsy (PSP, n=5), and dentatoruburopallidoluysian atrophy (DRPLA, n=3). MR images 5-10 mm in thickness were obtained in both axial and coronal sections. In all patients with Parkinson's disease, there was non-specific age-related cortical atrophy on T[sub 1]-weighted images. T[sub 2]-weighted imaging showed not only putaminal hypointensity, but also linear hyperintensity in the lateral part of putamen. However, these MR findings were not considered pathognomonic. All MSA patients showed atrophy of the brainstem and cerbellum on T[sub 1]-weighted images. Both proton density and T[sub 2]-weighted image showed increased signal intensity in the pontine transverse fibers between the tegmentum and basis pontis. These findings were correlated with atrophy degree of brainstem and middle cerebellar peduncles. It was also difficult to distinguish hyperintesnity in red nuclei from substantia nigra on T[sub 2]-weighted images. Severe atrophy of tegmentum of midbrain and high signal intensity area in the periaqueductal zone were found in all PSP patients on proton density images. Distinction between low signal areas of red nuclei and substantia nigra were obscure in these patients. In some cases of MSA and PSP, small oval hypointensity signals were also found in the superior colliculi. All DRPLA patients had cortical and cerebellar atrophy, but normal brainstem on T[sub 1]-weighted images. On proton density and T[sub 2]-weighted images, hyperintensity signal areas were found in the superior cerebellar peduncles. There was signal restoration in the dentate nuclei on T[sub 2]-weighted images. There was no specific change of signal intensity in the red nuclei, substantia nigra, basal ganglia, and cerebral white matter. (N.K.).

  14. MODERN CAPABILITIES OF BREAST PATHOLOGY DIAGNOSTICS

    Directory of Open Access Journals (Sweden)

    I. V. Vysotskaya

    2015-01-01

    Full Text Available Every year more than 1 million new cases of breast cancer are being recorded worldwide. Choice of appropriate tactics of treatment depends on the timely diagnosis and correct assessment of the prevalence of cancer.The algorithm of patient»s examination includes clinical examination, X-ray mammography and ultrasonic diagnosis of breast. However, this is not sufficient for a complete interpretation of the patient»s condition in case of non-palpable breast formations, ambiguous interpretation of imaging under structural changes, increased density of breast tissue, etc.In this regard, the introduction of new technologies and their evaluation in terms of practicality is a logical and developing method of early diagnosis of breast pathology.One of the methods that enables enhancing the information capability of ultrasonic diagnosis of breast is elastography. It allows for the differential diagnosis of benign and malignant changes not only in the breast tissue, but also in the areas of regional lymph drainage.Promising method of modern diagnostic breast care is digital mammography tomosynthesis. However, in spite of the first and very optimisticdata, this technique is still far from standard.Complex diagnostics of breast pathology, in addition to clinical data and imaging results, are based on information obtained from biopsies. At the present stage core-biopsy is considered as the best way of verification, where the resulting material is subjected to immunohistochemical studies.Thus, the spectrum of diagnostic capabilities is constantly expanding. Highly informative techniques included in the daily practice today enable clinicians to achieve optimal results in curing even greater number of patients.

  15. Contrast-enhanced helical CT of the pancreas. Optimal timing of imaging for pancreatic tumor evaluation

    International Nuclear Information System (INIS)

    Koide, Kazuki; Sekiguchi, Ryuzo

    2001-01-01

    We performed three-phase helical CT in patients suspected pancreatic tumors and investigated the optimal timing of imaging for evaluation of the pancreatic mass. The pancreatic-phase was superior in detecting pancreatic tumors, including islet cell tumors that may show strong enhancement. However, portal vein-phase imaging was also superior in 16.7% of our patients. Taking into account examination for hepatic metastasis, helical CT of any pancreatic tumor should include images obtained in the pancreatic and portal vein phases. (author)

  16. Medical image transmission via communication satellite: evaluation of ultrasonographic images.

    Science.gov (United States)

    Suzuki, H; Horikoshi, H; Shiba, H; Shimamoto, S

    1996-01-01

    As compared with terrestrial circuits, communication satellites possess superior characteristics such as wide area coverage, broadcasting functions, high capacity, and resistance to disasters. Utilizing the narrow band channel (64 kbps) of the stationary communication satellite JCSAT1 located at an altitude of 36,000 km above the equator, we investigated satelliterelayed dynamic medical images transmitted by video signals, using hepatic ultrasonography as a model. We conclude that the "variable playing speed transmission scheme" proposed by us is effective for the transmission of dynamic images in the narrow band channel. This promises to permit diverse utilization and applications for purposes such as the transmission of other types of ultrasonic images as well as remotely directed medical diagnosis and treatment.

  17. Prosopomorphic vessels from Moesia Superior

    Directory of Open Access Journals (Sweden)

    Nikolić Snežana

    2008-01-01

    Full Text Available The prosopomorphic vessels from Moesia Superior had the form of beakers varying in outline but similar in size. They were wheel-thrown, mould-made or manufactured by using a combination of wheel-throwing and mould-made appliqués. Given that face vessels are considerably scarcer than other kinds of pottery, more than fifty finds from Moesia Superior make an enviable collection. In this and other provinces face vessels have been recovered from military camps, civilian settlements and necropolises, which suggests that they served more than one purpose. It is generally accepted that the faces-masks gave a protective role to the vessels, be it to protect the deceased or the family, their house and possessions. More than forty of all known finds from Moesia Superior come from Viminacium, a half of that number from necropolises. Although tangible evidence is lacking, there must have been several local workshops producing face vessels. The number and technological characteristics of the discovered vessels suggest that one of the workshops is likely to have been at Viminacium, an important pottery-making centre in the second and third centuries.

  18. The Development of the Picture-Superiority Effect

    Science.gov (United States)

    Whitehouse, Andrew J. O.; Maybery, Murray T.; Durkin, Kevin

    2006-01-01

    When pictures and words are presented serially in an explicit memory task, recall of the pictures is superior. While this effect is well established in the adult population, little is known of the development of this picture-superiority effect in typical development. This task was administered to 80 participants from middle childhood to…

  19. TAURUS - a wide field imaging Fabry-Perot spectrometer

    International Nuclear Information System (INIS)

    Atherton, P.D.; Taylor, K.

    1983-01-01

    TAURUS, an imaging Fabry-Perot system developed by the Royal Greenwich Observatory and Imperial College London, is described. The imaging process is explained and the technique is compared with grating spectrographs. It is argued that TAURUS is superior for obtaining field information from extended emission line sources. (Auth.)

  20. Advanced image-based virtual monoenergetic dual-energy CT angiography of the abdomen: optimization of kiloelectron volt settings to improve image contrast

    International Nuclear Information System (INIS)

    Albrecht, Moritz H.; Scholtz, Jan-Erik; Huesers, Kristina; Beeres, Martin; Bucher, Andreas M.; Kaup, Moritz; Martin, Simon S.; Fischer, Sebastian; Bodelle, Boris; Bauer, Ralf W.; Lehnert, Thomas; Vogl, Thomas J.; Wichmann, Julian L.

    2016-01-01

    To compare quantitative image quality parameters in abdominal dual-energy computed tomography angiography (DE-CTA) using an advanced image-based (Mono+) reconstruction algorithm for virtual monoenergetic imaging and standard DE-CTA. Fifty-five patients (36 men; mean age, 64.2 ± 12.7 years) who underwent abdominal DE-CTA were retrospectively included. Mono + images were reconstructed at 40, 50, 60, 70, 80, 90 and 100 keV levels and as standard linearly blended M 0 .6 images (60 % 100 kV, 40 % 140 kV). The contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) of the common hepatic (CHA), splenic (SA), superior mesenteric (SMA) and left renal arteries (LRA) were objectively measured. Mono+ DE-CTA series showed a statistically superior CNR for 40, 50, 60, 70 and 80 keV (P < 0.031) compared to M 0 .6 images for all investigated arteries except SMA at 80 keV (P = 0.08). CNR at 40 keV revealed a mean relative increase of 287.7 % compared to linearly blended images among all assessed arteries (P < 0.001). SNR of Mono+ images was consistently significantly higher at 40, 50, 60 and 70 keV compared to M 0 .6 for CHA and SA (P < 0.009). Compared to linearly blended images, Mono+ reconstructions at low keV levels of abdominal DE-CTA datasets significantly improve quantitative image quality. (orig.)

  1. Diagnostic imagings and embolotherapy for the superior mesenteric vein-inferior vena cava shunt

    International Nuclear Information System (INIS)

    Morita, Yutaka; Yamada, Masataka; Miyata, Mutsuhiko; Kubo, Kohzo.

    1994-01-01

    Diagnostic imaging and embolization therapy for the uncommon portal and mesenteric vein-inferior vena cave shunt (PV·SMV-IVC shunt) are reported. As the frequency of clinical symptoms such as hematemesis, melena and confusion caused by gastrointestinal varices, or hepatoencephalopathy was about 40%, it was important for this disease entity to be diagnosed with noninvasive diagnostic images. The careful examination of the area around the right renal vein was able to overcome the low diagnostic rate of 20-40% obtained with US and CT images. In cases of simple PV·SMV-IVC shut without gastrointestinal varices, embolization therapy using steel coils and done by the intravenous approach is easy and noninvasive. On the other hand, in cases of complex PV-SMV-IVC shunt with gastrointestinal varices, dual balloon occluded embolization therapy using a liquid sclerosing agent and done by the intravenous and portal approaches is preferable. (author)

  2. VIP: Vortex Image Processing Package for High-contrast Direct Imaging

    Science.gov (United States)

    Gomez Gonzalez, Carlos Alberto; Wertz, Olivier; Absil, Olivier; Christiaens, Valentin; Defrère, Denis; Mawet, Dimitri; Milli, Julien; Absil, Pierre-Antoine; Van Droogenbroeck, Marc; Cantalloube, Faustine; Hinz, Philip M.; Skemer, Andrew J.; Karlsson, Mikael; Surdej, Jean

    2017-07-01

    We present the Vortex Image Processing (VIP) library, a python package dedicated to astronomical high-contrast imaging. Our package relies on the extensive python stack of scientific libraries and aims to provide a flexible framework for high-contrast data and image processing. In this paper, we describe the capabilities of VIP related to processing image sequences acquired using the angular differential imaging (ADI) observing technique. VIP implements functionalities for building high-contrast data processing pipelines, encompassing pre- and post-processing algorithms, potential source position and flux estimation, and sensitivity curve generation. Among the reference point-spread function subtraction techniques for ADI post-processing, VIP includes several flavors of principal component analysis (PCA) based algorithms, such as annular PCA and incremental PCA algorithms capable of processing big datacubes (of several gigabytes) on a computer with limited memory. Also, we present a novel ADI algorithm based on non-negative matrix factorization, which comes from the same family of low-rank matrix approximations as PCA and provides fairly similar results. We showcase the ADI capabilities of the VIP library using a deep sequence on HR 8799 taken with the LBTI/LMIRCam and its recently commissioned L-band vortex coronagraph. Using VIP, we investigated the presence of additional companions around HR 8799 and did not find any significant additional point source beyond the four known planets. VIP is available at http://github.com/vortex-exoplanet/VIP and is accompanied with Jupyter notebook tutorials illustrating the main functionalities of the library.

  3. Brain spect imaging

    International Nuclear Information System (INIS)

    Lee, R.G.L.; Hill, T.C.; Holman, B.L.

    1989-01-01

    This paper discusses how the rapid development of single-photon radiopharmaceuticals has given new life to tomographic brain imaging in nuclear medicine. Further developments in radiopharmaceuticals and refinements in neuro-SPECT (single-photon emission computed tomography) instrumentation should help to reinstate brain scintigraphy as an important part of neurologic diagnosis. SPECT of the brain evolved from experimentation using prototype instrumentation during the early 1960s. Although tomographic studies provided superior diagnostic accuracy when compared to planar techniques, the arrival of X-ray CT of the head resulted in the rapid demise of technetium brain imaging

  4. Extending the imaging volume for biometric iris recognition.

    Science.gov (United States)

    Narayanswamy, Ramkumar; Johnson, Gregory E; Silveira, Paulo E X; Wach, Hans B

    2005-02-10

    The use of the human iris as a biometric has recently attracted significant interest in the area of security applications. The need to capture an iris without active user cooperation places demands on the optical system. Unlike a traditional optical design, in which a large imaging volume is traded off for diminished imaging resolution and capacity for collecting light, Wavefront Coded imaging is a computational imaging technology capable of expanding the imaging volume while maintaining an accurate and robust iris identification capability. We apply Wavefront Coded imaging to extend the imaging volume of the iris recognition application.

  5. US and MR imaging of pelvic masses

    International Nuclear Information System (INIS)

    Angtuaco, T.L.; Boyd, C.M.; Mattison, D.R.; Williamson, M.R.; Sanders, M.M.; Bard, D.S.

    1987-01-01

    US and MR imaging were compared in benign and malignant pelvic masses to determine where MR imaging may replace US. With regard to benign masses, MR imaging showed a significant advantage only in the imaging of teratomas. In malignancy, US was better than MR imaging in delineating internal architecture. MR imaging was superior in suggesting the origin and extent of masses, especially in large neoplasms. US remains a reliable tool in the initial evaluation of pelvic masses. When US studies are suboptimal, MR imaging should be performed as complementary study. MR imaging may replace US in the initial examination of large masses where US cannot depict the origin and extent

  6. Management of type II superior labrum anterior posterior lesions: a review of the literature

    Directory of Open Access Journals (Sweden)

    Xinning Li

    2010-02-01

    Full Text Available Superior labrum anterior and posterior lesions were first described in 1985 by Andrews et al. and later classified into four types by Synder et al. The most prevalent is type II which is fraying of the superior glenoid labrum with detachment of the biceps anchor. Superior labrum anterior posterior (SLAP lesions can also be associated with other shoulder pathology. Both MRI and MRA can be utilized in making the diagnosis with the coronal images being the most sensitive. The mechanism of injury can be either repetitive stress or acute trauma with the superior labrum most vulnerable to injury during the late cocking phase of throwing. A combination of the modified dynamic labral shear and O’Brien test can be used clinically in making the diagnosis of SLAP lesion. However, the most sensitive and specific test used to diagnosis specifically a type II SLAP lesion is the Biceps Load Test II. The management of type II SLAP lesions is controversial and dependent on patient characteristics. In the young high demanding overhead athlete, repair of the type II lesion is recommended to prevent glenohumeral instability. In middle-aged patients (age 25-45, repair of the type II SLAP lesion with concomitant treatment of other shoulder pathology resulted in better functional outcomes and patient satisfaction. Furthermore, patients who had a distinct traumatic event resulting in the type II SLAP tear did better functionally than patients who did not have the traumatic event when the lesion was repaired. In the older patient population (age over 45 years, minimum intervention (debridement, biceps tenodesis/tenotomy to the type II SLAP lesion results in excellent patient satisfaction and outcomes.

  7. Missed pancreatic ductal adenocarcinoma: Assessment of early imaging findings on prediagnostic magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Kyung Mi; Kim, Seong Hyun, E-mail: sh6453.kim@samsung.com; Kim, Young Kon; Song, Kyoung Doo; Lee, Soon Jin; Choi, Dongil

    2015-08-15

    Highlights: • MR imaging was superior to CT for the detection of early PDAC. • A focal lesion with no MPD interruption is common MR finding of early PDAC. • A mean volume doubling time of early PDAC was about five months. - Abstract: Objective: To investigate the early imaging findings and growth rate of pancreatic ductal adenocarcinoma (PDAC), and to assess whether MR imaging detects early PDAC better than CT. Materials and methods: The institutional review board approved this retrospective study and waived the requirement for informed consent. Twenty-two patients were included, and two radiologists, by consensus, assessed the presence of focal lesions, interruption of the main pancreatic duct (MPD), MPD dilatation, and pancreatitis, volume doubling time (VDT) of PDAC on prediagnostic MR imaging. Two other observers independently reviewed three image sets (CT images, unenhanced MR images, and unenhanced and contrast-enhanced MR images) for the detection of early PDAC. Paired Wilcoxon signed rank test and receiver operating characteristic (ROC) curve analysis were used for statistical analyses. Results: In 20 (90.9%) patients, prediagnostic MR exams showed abnormality, and all of them showed focal lesions on the first abnormal prediagnostic MR exams. Thirteen lesions (65%) showed no MPD interruption and one lesion (5%) was accompanied by pancreatitis. The mean VDT of PDAC was 151.7 days (range, 18.3–417.8 days). Diagnostic performance of unenhanced MR images (Az, 0.971–0.989) and combined unenhanced and contrast-enhanced MR images (Az, 0.956–0.963) was significantly better than that of CT images (Az, 0.565–0.583; p < 0.01) for both observers, Conclusion: The most common early imaging finding of PDAC on prediagnostic MR exams was a focal lesion with no MPD interruption with a mean volume doubling time of five months. MR imaging was superior to CT for the detection of early PDAC.

  8. Quantitative perfusion imaging in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Zoellner, F.G.; Gaa, T.; Zimmer, F.; Ong, M.M.; Riffel, P.; Hausmann, D.; Schoenberg, S.O.; Weis, M.

    2016-01-01

    Magnetic resonance imaging (MRI) is recognized for its superior tissue contrast while being non-invasive and free of ionizing radiation. Due to the development of new scanner hardware and fast imaging techniques during the last decades, access to tissue and organ functions became possible. One of these functional imaging techniques is perfusion imaging with which tissue perfusion and capillary permeability can be determined from dynamic imaging data. Perfusion imaging by MRI can be performed by two approaches, arterial spin labeling (ASL) and dynamic contrast-enhanced (DCE) MRI. While the first method uses magnetically labelled water protons in arterial blood as an endogenous tracer, the latter involves the injection of a contrast agent, usually gadolinium (Gd), as a tracer for calculating hemodynamic parameters. Studies have demonstrated the potential of perfusion MRI for diagnostics and also for therapy monitoring. The utilization and application of perfusion MRI are still restricted to specialized centers, such as university hospitals. A broad application of the technique has not yet been implemented. The MRI perfusion technique is a valuable tool that might come broadly available after implementation of standards on European and international levels. Such efforts are being promoted by the respective professional bodies. (orig.) [de

  9. Vertebral uptake of Tc-99m macroaggregated albumin (MAA) with SPECT/CT occurring in superior vena cava obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Karls, Shawn; Hassoun, Hani; Derbekyan, Vilma [Dept. of Nuclear Madicine, Royal Victoria Hospital, Montreal (Canada)

    2016-09-15

    A 67-year-old male presented with dyspnea for which lung scintigraphy was ordered to rule out pulmonary embolus. Planar images demonstrated abnormal midline uptake of Tc-99m macroaggregated albumin, which SPECT/CT localized to several thoracic vertebrae. Thoracic vertebral uptake on perfusion lung scintigraphy was previously described on planar imaging. Radionuclide venography and contrast-enhanced CT subsequently demonstrated superior vena cava (SVC) obstruction with collateralization through the azygous/hemiazygous system and vertebral venous plexus. SPECT/CT differentiated residual esophageal/tracheal ventilation activity, a clinically insignificant finding, from vertebral uptake indicative of SVC obstruction, a potentially life-threatening condition.

  10. Writing superiority in cued recall

    Directory of Open Access Journals (Sweden)

    Carina eFueller

    2013-10-01

    Full Text Available In list learning paradigms with free recall, written recall has been found to be less susceptible to intrusions of related concepts than spoken recall when the list items had been visually presented. This effect has been ascribed to the use of stored orthographic representations from the study phase during written recall (Kellogg, 2001. In other memory retrieval paradigms, either better recall for modality-congruent items or an input-independent writing superiority effect have been found (Grabowski, 2005. In a series of four experiments using a paired associate (PA learning paradigm we tested (a whether output modality effects on verbal recall can be replicated in a paradigm that does not involve the rejection of semantically related intrusion words, (b whether a possible superiority for written recall was due to a slower response onset for writing as compared to speaking in immediate recall, and (c whether the performance in PA word recall was correlated with performance in an additional episodic memory task. We found better written recall in the first half of the recall phase, irrespective of the modality in which the material was presented upon encoding. An explanation based on longer response latencies for writing and hence more time for retrieval could be ruled out by showing that the effect persisted in delayed response versions of the task. Although there was some evidence that stored additional episodic information may contribute to the successful retrieval of associate words, this evidence was only found in the immediate response experiments and hence is most likely independent from the observed output modality effect. In sum, our results from a PA learning paradigm suggest that superior performance for written versus spoken recall cannot be (solely explained in terms of additional access to stored orthographic representations from the encoding phase. Our findings rather suggest a general writing-superiority effect at the time of memory

  11. MR imaging of the shoulder

    International Nuclear Information System (INIS)

    Fritts, H.M.; Craig, E.; Kyle, R.; Strefling, M.; Miller, D.; Heithoff, K.; Schellhas, K.

    1988-01-01

    Magnetic resonance (MR) imaging (1.5-T unit) was performed in over 600 shoulders to evaluate shoulder pain. Ultrasound (US) and arthrography were performed in over 100 patients. Surgery was performed in over 75 patients. MR imaging offers information not well evaluated with other modalities, including bony impingement, tendinitis, bursitis, and osseous abnormalities, such as primary arthritis, avascular necrosis, occult fractures, and tumors. US and MR findings correlate well with surgical findings for medium to large rotator cuff tears. MR imaging with T2 weighting is superior for differentiating small tears from associated tendinitis. An algorithm for cost-effective shoulder imaging integrating US, MR imaging, arthrography, and computed tomographic arthrography are presented

  12. Human arachnoid granulations Part I: a technique for quantifying area and distribution on the superior surface of the cerebral cortex

    Directory of Open Access Journals (Sweden)

    Holman David W

    2007-07-01

    Full Text Available Abstract Background The arachnoid granulations (AGs are herniations of the arachnoid membrane into the dural venous sinuses on the surface of the brain. Previous morphological studies of AGs have been limited in scope and only one has mentioned surface area measurements. The purpose of this study was to investigate the topographic distribution of AGs on the superior surface of the cerebral cortex. Methods En face images were taken of the superior surface of 35 formalin-fixed human brains. AGs were manually identified using Adobe Photoshop, with a pixel location containing an AG defined as 'positive'. A set of 25 standard fiducial points was marked on each hemisphere for a total of 50 points on each image. The points were connected on each hemisphere to create a segmented image. A standard template was created for each hemisphere by calculating the average position of the 25 fiducial points from all brains. Each segmented image was mapped to the standard template using a linear transformation. A topographic distribution map was produced by calculating the proportion of AG positive images at each pixel in the standard template. The AG surface area was calculated for each hemisphere and for the total brain superior surface. To adjust for different brain sizes, the proportional involvement of AGs was calculated by dividing the AG area by the total area. Results The total brain average surface area of AGs was 78.53 ± 13.13 mm2 (n = 35 and average AG proportional involvement was 57.71 × 10-4 ± 7.65 × 10-4. Regression analysis confirmed the reproducibility of AG identification between independent researchers with r2 = 0.97. The surface AGs were localized in the parasagittal planes that coincide with the region of the lateral lacunae. Conclusion The data obtained on the spatial distribution and en face surface area of AGs will be used in an in vitro model of CSF outflow. With an increase in the number of samples, this analysis technique can be used

  13. Magnetic resonance imaging (MRI) in diffuse liver diseases. Comparison with CT

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Masaharu; Ebara, Masaaki; Ohto, Masao

    1987-06-01

    MRI (Magnetic Resonance Imaging) was performed in 74 patients with chronic hepatitis, liver cirrhosis, idiopathic portal hypertension, Budd-Chiari syndrome, extrahepatic protal vein occlusion, Wilson disease and hemochromatosis. We measured relaxation time of the liver and the spleen in these patients and compared MRI with CT in the diagnostic capability. MRI was superior to plain CT in the detection of collateral vessels in liver cirrhosis and extrahepatic protal vein occlusion. MRI could also demonstrate the occluded part of the inferior vena cava in Budd-Chiari syndrome. However, MRI was almost the same as CT in the visualization of the hepatic configuration in liver cirrhosis. In liver cirrhosis, T1 values of the liver and the spleen were longer than those in normal controls, and T1 values of the liver were correlated with ICG R-15. Hepatic T1 values in Budd-Chiari syndrome were longer than those in normal controls.

  14. Superior facet syndrome

    International Nuclear Information System (INIS)

    Kubo, Yoshichika; Igarashi, Seishi; Koyama, Tsunemaro

    1985-01-01

    Sciatica caused by root entrapment in the lateral recess was named superior facet syndrome by Epstein in 1972. Few reports on this subject based on large numbers of cases have been documented to date. Of the patients with sciatica, 32 patients were diagnosed to have root entrapment at the lateral recess L 5 or/and S 1 lumbar spine. Out of 32 patients, 20 patients were operated on and the lateral entrapment was recognized in all of surgical cases. Neuroradiological findings, especially of metrizamide CT (met. CT), were documented in detail. Thirty two patients were classified in three types according to radiological findings. They were congenital or developmental, degenerative, and combined type, respectively, Fourteen cases belonged to the congenital type, 13 to the degenerative and 5 to the combined type. Each group had the mean ages of 23.4, 53.8, and 36.8 years old, respectively. Of 32 cases the entrapment occured in 47 L 5 roots and 11 S 1 roots. There was no remarkable laterality. In operation the unroofing of the lateral recess were done and the sciatica subsided postoperatively in all of surgical cases. Met. CT revealed extreme medial protrusion of the superior articular joint in 18 of 24 cases(75%) and none filling of the root in the lateral recess in 21 of 24 cases (87.5%). In the degenerative type, met. CT showed some degenerative changes that were hypertrophy or deformity of the articular joints and spur formation of the vertebral body. In contrast to met. CT, metrizamide myelography revealed only slight changes, which were poor filling of the root before it turned out the pedicle of lateral compression of the root. In plain films or lumbar spine articular joints at Lsub(4/5) were formed in coronal plane in 69% of cases of the L 5 root entrapment. Met. CT using ReView technique was of great diagnostic value in superior facet syndrome. (author)

  15. Semiconductor Laser Multi-Spectral Sensing and Imaging

    Directory of Open Access Journals (Sweden)

    Han Q. Le

    2010-01-01

    Full Text Available Multi-spectral laser imaging is a technique that can offer a combination of the laser capability of accurate spectral sensing with the desirable features of passive multispectral imaging. The technique can be used for detection, discrimination, and identification of objects by their spectral signature. This article describes and reviews the development and evaluation of semiconductor multi-spectral laser imaging systems. Although the method is certainly not specific to any laser technology, the use of semiconductor lasers is significant with respect to practicality and affordability. More relevantly, semiconductor lasers have their own characteristics; they offer excellent wavelength diversity but usually with modest power. Thus, system design and engineering issues are analyzed for approaches and trade-offs that can make the best use of semiconductor laser capabilities in multispectral imaging. A few systems were developed and the technique was tested and evaluated on a variety of natural and man-made objects. It was shown capable of high spectral resolution imaging which, unlike non-imaging point sensing, allows detecting and discriminating objects of interest even without a priori spectroscopic knowledge of the targets. Examples include material and chemical discrimination. It was also shown capable of dealing with the complexity of interpreting diffuse scattered spectral images and produced results that could otherwise be ambiguous with conventional imaging. Examples with glucose and spectral imaging of drug pills were discussed. Lastly, the technique was shown with conventional laser spectroscopy such as wavelength modulation spectroscopy to image a gas (CO. These results suggest the versatility and power of multi-spectral laser imaging, which can be practical with the use of semiconductor lasers.

  16. Semiconductor laser multi-spectral sensing and imaging.

    Science.gov (United States)

    Le, Han Q; Wang, Yang

    2010-01-01

    Multi-spectral laser imaging is a technique that can offer a combination of the laser capability of accurate spectral sensing with the desirable features of passive multispectral imaging. The technique can be used for detection, discrimination, and identification of objects by their spectral signature. This article describes and reviews the development and evaluation of semiconductor multi-spectral laser imaging systems. Although the method is certainly not specific to any laser technology, the use of semiconductor lasers is significant with respect to practicality and affordability. More relevantly, semiconductor lasers have their own characteristics; they offer excellent wavelength diversity but usually with modest power. Thus, system design and engineering issues are analyzed for approaches and trade-offs that can make the best use of semiconductor laser capabilities in multispectral imaging. A few systems were developed and the technique was tested and evaluated on a variety of natural and man-made objects. It was shown capable of high spectral resolution imaging which, unlike non-imaging point sensing, allows detecting and discriminating objects of interest even without a priori spectroscopic knowledge of the targets. Examples include material and chemical discrimination. It was also shown capable of dealing with the complexity of interpreting diffuse scattered spectral images and produced results that could otherwise be ambiguous with conventional imaging. Examples with glucose and spectral imaging of drug pills were discussed. Lastly, the technique was shown with conventional laser spectroscopy such as wavelength modulation spectroscopy to image a gas (CO). These results suggest the versatility and power of multi-spectral laser imaging, which can be practical with the use of semiconductor lasers.

  17. Cell phones as imaging sensors

    Science.gov (United States)

    Bhatti, Nina; Baker, Harlyn; Marguier, Joanna; Berclaz, Jérôme; Süsstrunk, Sabine

    2010-04-01

    Camera phones are ubiquitous, and consumers have been adopting them faster than any other technology in modern history. When connected to a network, though, they are capable of more than just picture taking: Suddenly, they gain access to the power of the cloud. We exploit this capability by providing a series of image-based personal advisory services. These are designed to work with any handset over any cellular carrier using commonly available Multimedia Messaging Service (MMS) and Short Message Service (SMS) features. Targeted at the unsophisticated consumer, these applications must be quick and easy to use, not requiring download capabilities or preplanning. Thus, all application processing occurs in the back-end system (i.e., as a cloud service) and not on the handset itself. Presenting an image to an advisory service in the cloud, a user receives information that can be acted upon immediately. Two of our examples involve color assessment - selecting cosmetics and home décor paint palettes; the third provides the ability to extract text from a scene. In the case of the color imaging applications, we have shown that our service rivals the advice quality of experts. The result of this capability is a new paradigm for mobile interactions - image-based information services exploiting the ubiquity of camera phones.

  18. Motor mechanisms of vertical fusion in individuals with superior oblique paresis.

    Science.gov (United States)

    Mudgil, Ananth V; Walker, Mark; Steffen, Heimo; Guyton, David L; Zee, David S

    2002-06-01

    We wanted to determine the mechanisms of motor vertical fusion in patients with superior oblique paresis and to correlate these mechanisms with surgical outcomes. Ten patients with superior oblique paresis underwent 3-axis, bilateral, scleral search coil eye movement recordings. Eye movements associated with fusion were analyzed. Six patients had decompensated congenital superior oblique paresis and 4 had acquired superior oblique paresis. All patients with acquired superior oblique paresis relied predominantly on the vertical rectus muscles for motor fusion. Patients with congenital superior oblique paresis were less uniform in their mechanisms for motor fusion: 2 patients used predominantly the oblique muscles, 2 patients used predominantly the vertical recti, and 2 patients used predominantly the superior oblique in the hyperdeviated eye and the superior rectus in the hypodeviated eye. The last 2 patients developed the largest changes in torsional eye alignment relative to changes in vertical eye alignment and were the only patients to develop symptomatic surgical overcorrections. There are 3 different mechanisms for vertical fusion in individuals with superior oblique paresis, with the predominant mechanism being the vertical recti. A subset of patients with superior oblique paresis uses predominantly the superior oblique muscle in the hyperdeviated paretic eye and the superior rectus muscle in the fellow eye for fusion. This results in intorsion of both eyes, causing a large change in torsional alignment. The consequent cyclodisparity, in addition to the existing vertical deviation, may make fusion difficult. The differing patterns of vertical fusional vergence may have implications for surgical treatment.

  19. MR Imaging of the Triangular Fibrocartilage Complex.

    Science.gov (United States)

    Cody, Michael E; Nakamura, David T; Small, Kirstin M; Yoshioka, Hiroshi

    2015-08-01

    MR imaging has emerged as the mainstay in imaging internal derangement of the soft tissues of the musculoskeletal system largely because of superior contrast resolution. The complex geometry and diminutive size of the triangular fibrocartilage complex (TFCC) and its constituent structures can make optimal imaging of the TFCC challenging; therefore, production of clinically useful images requires careful optimization of image acquisition parameters. This article provides a foundation for advanced TFCC imaging including factors to optimize magnetic resonance images, arthrography, detailed anatomy, and classification of injury. In addition, clinical presentations and treatments for TFCC injury are briefly considered. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Marketing at Superior: Theory meets application in the field

    International Nuclear Information System (INIS)

    Jeffrey, S.

    1992-01-01

    The field marketing practices of Superior Propane in rural Ontario are illustrated. In the Smithville area, Superior's customer base consists of agricultural, industrial, commercial, and residential customers, plus a large market for auto propane. A 6,900 ft 2 showroom presents a representative selection of the wide range of appliances using propane. Superior's Smithville branch is one of the top five in Canada, in terms of volume. To expand business beyond its traditional branch structures, Superior has an Independent Partners Program which is aimed at all phases of business including independent sales agents, conversions, propane fuel stops, appliance installations, and building contractors. In Keswick, located in the summer resort region on the south shore of Lake Simcoe, Superior's base load is 40% commercial and 20% each agricultural, residential, and automotive. A new 4,100 ft 2 showroom was recently constructed with separate display units for each appliance. The new building has brought increases in auto propane and appliance sales. The different branches of Superior Propane are able to tailor their marketing programs according to local needs by choosing the appropriate programs from those available at head office. 5 figs

  1. Postoperative imaging of the shoulder

    International Nuclear Information System (INIS)

    Woertler, K.; Rummeny, E.J.

    2004-01-01

    Correct interpretation of imaging findings in the postoperative shoulder is impaired by surgical distortion of normal anatomy and possible artifacts. Advanced postoperative imaging of the shoulder in addition to the selection of the best suited modality necessitates familiarity with the surgical procedure that has been performed and its consecutive morphological changes. This article reviews the most common arthroscopic and open techniques used for treatment of shoulder instability, lesions of the superior labral-bicipital complex, primery impingement, and rotator cuff tears, their typical postoperative imaging findings, as well as the diagnostic performance of cross sectional imaging techniques in the detection of recurrent lesions and complications. (orig.) [de

  2. Dynamic capabilities and innovation capabilities: The case of the ‘Innovation Clinic’

    Directory of Open Access Journals (Sweden)

    Fred Strønen

    2017-01-01

    Full Text Available In this explorative study, we investigate the relationship between dynamic capabilities and innovation capabilities. Dynamic capabilities are at the core of strategic management in terms of how firms can ensure adaptation to changing environments over time. Our paper follows two paths of argumentation. First, we review and discuss some major contributions to the theories on ordinary capabilities, dynamic capabilities, and innovation capabilities. We seek to identify different understandings of the concepts in question, in order to clarify the distinctions and relationships between dynamic capabilities and innovation capabilities. Second, we present a case study of the ’Innovation Clinic’ at a major university hospital, including four innovation projects. We use this case study to explore and discuss how dynamic capabilities can be extended, as well as to what extent innovation capabilities can be said to be dynamic. In our conclusion, we discuss the conditions for nurturing ‘dynamic innovation capabilities’ in organizations.

  3. Intracranially protruded bilateral posterior and superior SCCs with multiple dehiscences in a patient with positional vertigo: CT and MR imaging findings and review of literature

    International Nuclear Information System (INIS)

    Kundaragi, Nischal G; Mudali, Srinivasa; Karpagam, Bulabai; Priya, Rathna

    2014-01-01

    We report a rare case of intracranially protruded posterior and superior semicircular canals beyond the margins of temporal bone with bony roof dehiscence in bilateral posterior and left superior semicircular canals in a patient with benign paroxysmal positional vertigo (BPPV)

  4. Fast spin-echo imaging

    International Nuclear Information System (INIS)

    Mackey, K.; Zoarski, G.; Bentson, J.R.; Lufkin, R.B.; Melki, P.; Jolesz, F.

    1991-01-01

    This paper reports on a partial radio-frequency (RF) echo-planar pulse sequence called contiguous slice fast spin echo (CSFSE) which is undergoing clinical trials for spine MR imaging. In this variation of rapid acquisition relaxation enhanced (RARE) spin-echo imaging, rapid 180 degrees RF pulse generated refocused echoes, producing T2-weighted images in about one-third the time of conventional double-echo technique. Forty patients with suspected pathology of the spine were imaged with conventional double-echo and closely matched CSFSE techniques on a GE Signa 1.5-T Advantage system. Cases were reviewed by two board-certified neuroradiologists. In all cases the CSFSE images were of equal or superior quality compared with those obtained with the conventional double-echo technique. Pathologic processes that were imaged consisted of inflammatory, neoplastic, posttraumatic, and degenerative conditions

  5. Imaging autofluorescence temporal signatures of the human ocular fundus in vivo

    Science.gov (United States)

    Papour, Asael; Taylor, Zachary; Stafsudd, Oscar; Tsui, Irena; Grundfest, Warren

    2015-11-01

    We demonstrate real-time in vivo fundus imaging capabilities of our fluorescence lifetime imaging technology for the first time. This implementation of lifetime imaging uses light emitting diodes to capture full-field images capable of showing direct tissue contrast without executing curve fitting or lifetime calculations. Preliminary results of fundus images are presented, investigating autofluorescence imaging potential of various retina biomarkers for early detection of macular diseases.

  6. Capability ethics

    OpenAIRE

    Robeyns, Ingrid

    2012-01-01

    textabstractThe capability approach is one of the most recent additions to the landscape of normative theories in ethics and political philosophy. Yet in its present stage of development, the capability approach is not a full-blown normative theory, in contrast to utilitarianism, deontological theories, virtue ethics, or pragmatism. As I will argue in this chapter, at present the core of the capability approach is an account of value, which together with some other (more minor) normative comm...

  7. First mesospheric wind images using the Michelson interferometer for airglow dynamics imaging.

    Science.gov (United States)

    Langille, J A; Ward, W E; Nakamura, T

    2016-12-10

    The Michelson interferometer for airglow dynamics imaging (MIADI) is a ground-based instrument that combines an imaging capability with the Doppler Michelson interferometry in order to remotely detect motions in the mesopause region using spectrally isolated airglow emissions: the O(S1) emission at 557.73 nm and the OH (6, 2) P1 (2) at 839.918 nm. A measurement and analysis approach has been developed that allows simultaneous images of the line-of-sight Doppler wind field and irradiance field to be obtained. A working field instrument was installed and tested at a field site outside Fredericton, NB (45.96 N, 66.65 W) during the summer of 2014. Successful measurements over a 6 h period were obtained on 31 July 2014. This paper describes the MIADI measurement and analysis approach and presents the work that has been done to extract images of the line-of-sight Doppler wind field and irradiances from these observations. The imaging capability is validated by identifying the presence of large-scale and small-scale geophysical perturbations in the images.

  8. IMPROVING THE QUALITY OF NEAR-INFRARED IMAGING OF IN VIVOBLOOD VESSELS USING IMAGE FUSION METHODS

    DEFF Research Database (Denmark)

    Jensen, Andreas Kryger; Savarimuthu, Thiusius Rajeeth; Sørensen, Anders Stengaard

    2009-01-01

    We investigate methods for improving the visual quality of in vivo images of blood vessels in the human forearm. Using a near-infrared light source and a dual CCD chip camera system capable of capturing images at visual and nearinfrared spectra, we evaluate three fusion methods in terms...... of their capability of enhancing the blood vessels while preserving the spectral signature of the original color image. Furthermore, we investigate a possibility of removing hair in the images using a fusion rule based on the "a trous" stationary wavelet decomposition. The method with the best overall performance...... with both speed and quality in mind is the Intensity Injection method. Using the developed system and the methods presented in this article, it is possible to create images of high visual quality with highly emphasized blood vessels....

  9. Comparative study between rib imaging of DR dual energy subtraction technology and chest imaging

    International Nuclear Information System (INIS)

    Yu Jianming; Lei Ziqiao; Kong Xiangchuang

    2006-01-01

    Objective: To investigate the application value of DR dual energy subtraction technology in rib lesions. Methods: 200 patients were performed with chest DR dual energy subtraction, comparing the rib imaging between DR of thorax and chest imaging using ROC analysis. Results: Among the total of 200 patients, there are 50 cases of rib calcification, 7 cases of rib destruction, 22 cases of rib fracture. The calcification, destruction and fracture were displayed respectively by ribs below diaphragm and rib markings. The analytic parameter of rib imaging of DR dual energy subtraction Az is 0.9367, while that of rib imaging of chest Az is 0.6830. Conclusion: DR dual energy subtraction technology is superior to chest imaging in the displaying of rib lesion and ribs below diaphragm. (authors)

  10. Superior MR images with electronically tuned and decoupled surface coils

    International Nuclear Information System (INIS)

    Ingwersen, H.; Freisen, L.; Friedrich, A.; Kess, H.; Krause, N.; Meissner, R.; Popp, W.

    1987-01-01

    In order to gain free positioning of surface coils in linearly polarized transmitting coils, it is absolutely necessary to electronically decouple both coils. For circularly polarized transmitting coils, decoupling is necessary in any case. In addition to the decoupling circuit automatic electronic tuning of the surface coils is used to gain the bast ratio of signal to noise. This combination of electronically decoupling and tuning of the surface coils yields intrinsic patient safety concerning local power deposition as well as free positioning and easy handling at the same time. Block diagrams, circuit schemes, and MR images obtained with several different surface coils are shown

  11. Technical Note: Deformable image registration on partially matched images for radiotherapy applications

    International Nuclear Information System (INIS)

    Yang Deshan; Goddu, S. Murty; Lu Wei; Pechenaya, Olga L.; Wu Yu; Deasy, Joseph O.; El Naqa, Issam; Low, Daniel A.

    2010-01-01

    In radiation therapy applications, deformable image registrations (DIRs) are often carried out between two images that only partially match. Image mismatching could present as superior-inferior coverage differences, field-of-view (FOV) cutoffs, or motion crossing the image boundaries. In this study, the authors propose a method to improve the existing DIR algorithms so that DIR can be carried out in such situations. The basic idea is to extend the image volumes and define the extension voxels (outside the FOV or outside the original image volume) as NaN (not-a-number) values that are transparent to all floating-point computations in the DIR algorithms. Registrations are then carried out with one additional rule that NaN voxels can match any voxels. In this way, the matched sections of the images are registered properly, and the mismatched sections of the images are registered to NaN voxels. This method makes it possible to perform DIR on partially matched images that otherwise are difficult to register. It may also improve DIR accuracy, especially near or in the mismatched image regions.

  12. Surgical resection of grade II astrocytomas in the superior frontal gyrus.

    Science.gov (United States)

    Peraud, Aurelia; Meschede, Magnus; Eisner, Wilhelm; Ilmberger, Josef; Reulen, Hans-Jürgen

    2002-05-01

    Surgery in the superior frontal gyrus partially involving the supplementary motor area (SMA) may be followed by contralateral transient weakness and aphasia initially indistinguishable from damage to the primary motor cortex. However, recovery is different, and SMA deficits may resolve completely within days to weeks. No study has assessed the distinct postoperative deficits after tumor resection in the SMA on a homogeneous patient group. Twenty-four patients with World Health Organization Grade II astrocytomas in the superior frontal gyrus consecutively treated by surgery were studied. Degree and duration of postoperative deficits were evaluated according to tumor location and boundaries via magnetic resonance imaging scans, intraoperative neuromonitoring results, and extent of tumor resection. Postoperatively, motor deficits were evident in 21 of 24 and speech deficits in 9 of 12 patients. Motor function quickly recovered in 11 and speech function in 3 patients. None of the 12 patients in whom the posterior tumor resection line was at a distance of more than 0.5 cm from the precentral sulcus experienced persistent motor deficits. Eight of these patients developed typical SMA syndrome with transient initiation difficulties. Seven of 12 patients in whom the tumor extended to the precentral sulcus still had motor deficits at the 12-month follow-up assessment. Surgery for Grade II gliomas in the superior frontal gyrus is more likely to result in permanent morbidity when the resection is performed at a distance of less than 0.5 cm from the precentral gyrus or positive stimulation points. Therefore, cortical mapping of motor and speech function, in critical cases under local anesthesia with the patient as his or her own monitor, is recommended; resection should be tailored to obtain good functional outcome and maintain quality of life.

  13. T2-weighted images are superior to other MR image types for the determination of diffuse intrinsic pontine glioma intratumoral heterogeneity.

    Science.gov (United States)

    Harward, Stephen; Harrison Farber, S; Malinzak, Michael; Becher, Oren; Thompson, Eric M

    2018-03-01

    Diffuse intrinsic pontine glioma (DIPG) remains the main cause of death in children with brain tumors. Given the inefficacy of numerous peripherally delivered agents to treat DIPG, convection enhanced delivery (CED) of therapeutic agents is a promising treatment modality. The purpose of this study was to determine which MR imaging type provides the best discrimination of intratumoral heterogeneity to guide future stereotactic implantation of CED catheters into the most cellular tumor regions. Patients ages 18 years or younger with a diagnosis of DIPG from 2000 to 2015 were included. Radiographic heterogeneity index (HI) of the tumor was calculated by measuring the standard deviation of signal intensity of the tumor (SD Tumor ) normalized to the genu of the corpus callosum (SD Corpus Callosum ). Four MR image types (T2-weighted, contrast-enhanced T1-weighted, FLAIR, and ADC) were analyzed at several time points both before and after radiotherapy and chemotherapy. HI values across these MR image types were compared and correlated with patient survival. MR images from 18 patients with DIPG were evaluated. The mean survival ± standard deviation was 13.8 ± 13.7 months. T2-weighted images had the highest HI (mean ± SD, 5.1 ± 2.5) followed by contrast-enhanced T1-weighted images (3.7 ± 1.5), FLAIR images (3.0 ± 1.1), and ADC maps (1.6 ± 0.4). ANOVA demonstrated that HI values were significantly higher for T2-weighted images than FLAIR (p image HI values increased, while FLAIR and ADC HI values decreased. Univariate and multivariate analyses did not reveal a relationship between HI values and patient survival (p > 0.05). For children with DIPG, T2-weighted MRI demonstrates the greatest signal intensity variance suggesting tumor heterogeneity. Within this heterogeneity, T2-weighted signal hypointensity is known to correlate with increased cellularity and thus may represent a putative target for CED catheter placement in future clinical

  14. Brain MR imaging in child abuse

    International Nuclear Information System (INIS)

    Sato, Y.; Ellerbroek, C.J.; Alexander, R.; Kao, S.C.S.; Yuh, W.T.C.; Smith, W.L.

    1988-01-01

    Intracranial injuries represent the most severe manifestation of child abuse. CT of the brain is the current standard for evaluation of these infants; however, MR imaging offers several potential advantages. MR imaging and CT were performed in ten infants who suffered intracranial trauma owing to child abuse. CT was slightly better at demonstrating subarachnoid hemorrhage and had definite advantages for defining fractures. MR imaging was superior in the demonstration of subacute extraaxial hemorrhage, deep brain injuries owing to shearing effects from shaking, and anoxic injuries. MR imaging has a definite complementary role in the evaluation of acute intracranial trauma in child abuse victims

  15. Neurocognitive decrements are present in intellectually superior schizophrenia

    Directory of Open Access Journals (Sweden)

    Anja eVaskinn

    2014-05-01

    Full Text Available Data suggests that individuals with schizophrenia (SZ and superior intelligence can present without specific neurocognitive deficits. However, neurocognitive decrements, defined as worse cognition than expected, have been reported in practically all schizophrenia cases. This study investigated if neurocognitive decrements are present in intellectually superior SZ by comparing the neuropsychological profile of SZ cases with IQ-matched healthy controls (HC across intellectual level. Participants with SZ and HCs were stratified into three IQ-groups; intellectually low (IQ 80-95; SZ n = 65 & HC n = 13, intellectually normal (IQ = 100-115; SZ n = 111 & HC n = 115 and intellectually superior (IQ > 120; SZ n = 20 & HC n = 50. A repeated measures multivariate analysis of co-variance compared performance on eight selected neuropsychological tests across IQ-strata and diagnostic group. Differences in clinical characteristics and social functioning in SZ across IQ-strata were investigated with multivariate and univariate analyses of variance. Intellectually superior SZ participants scored within normal limits, but had neurocognitive decrements compared to superior HCs. Decrements were of the same magnitude as in the low and normal IQ-strata. Levels of functional impairments and clinical characteristics in participants with SZ did not differ significantly across IQ-strata. Results indicate that neurocognitive decrements are present in intellectually superior SZ to the same extent as in intellectually low and intellectually normal SZ, supporting the notion that SZ is a neurocognitive disorder. Similar levels of social functional deficits and clinical symptoms suggest similar disease processes in SZ across intellectual level.

  16. Gossiping Capabilities

    DEFF Research Database (Denmark)

    Mogensen, Martin; Frey, Davide; Guerraoui, Rachid

    Gossip-based protocols are now acknowledged as a sound basis to implement collaborative high-bandwidth content dissemination: content location is disseminated through gossip, the actual contents being subsequently pulled. In this paper, we present HEAP, HEterogeneity Aware gossip Protocol, where...... nodes dynamically adjust their contribution to gossip dissemination according to their capabilities. Using a continuous, itself gossip-based, approximation of relative capabilities, HEAP dynamically leverages the most capable nodes by (a) increasing their fanouts (while decreasing by the same proportion...... declare a high capability in order to augment their perceived quality without contributing accordingly. We evaluate HEAP in the context of a video streaming application on a 236 PlanetLab nodes testbed. Our results shows that HEAP improves the quality of the streaming by 25% over a standard gossip...

  17. Pure agraphia after infarction in the superior and middle portions of the left precentral gyrus: Dissociation between Kanji and Kana.

    Science.gov (United States)

    Kurosaki, Yoshiko; Hashimoto, Ryusaku; Tatsumi, Hiroshi; Hadano, Kazuo

    2016-04-01

    The present study describes a Japanese patient with pure agraphia displaying differential disturbances in processing Kanji (morphogram) and Kana (syllabogram) letters after an infarction in the middle and superior portions of the left precentral gyrus. Kana errors reflected the patient's difficulty with retrieving both motor and visual letter images, whereas Kanji errors included partial letter stroke omissions or additions. This present case suggests that differences in writing disturbances between Kana and Kanji letters are caused by a differential dependency on letter motor images. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Building EOS capability for Malaysia – the options

    International Nuclear Information System (INIS)

    Subari, M D; Hassan, A

    2014-01-01

    Earth observation satellite (EOS) is currently a major tool to monitor earth dynamics and increase human understanding of earth surface process. Since the early 80s, Malaysia has been using EOS images for various applications, such as weather forecasting, land use mapping, agriculture, environment monitoring and others. Until now, all EOS images were obtained from foreign satellite systems. Realising on the strategic need of having its own capability, Malaysia embarked into EOS development programs in the early 90s. Starting with TiungSAT-1, a micro-satellite carrying small camera, then followed by RazakSAT, a small satellite carrying 2.5 m panchromatic (PAN) medium-aperture-camera, the current satellite program development, the RazakSAT-2, designed to carry a 1.0 m high resolution PAN and 4.0m multi-spectral camera, would become a strategic initiative of the government in developing and accelerating the nation's capability in the area of satellite technology and its application. Would this effort continue until all needs of the remote sensing community being fulfilled by its own EOS? This paper will analyze the intention of the Malaysian government through its National Space Policy and other related policy documents, and proposes some policy options on this. Key factors to be considered are specific data need of the EOS community, data availability and the more subjective political motivations such as national pride

  19. Why do employees follow their superiors' instructions? Identification of the reasons to comply with superiors' will in a group of Polish employees.

    Science.gov (United States)

    Wójcik, Aleksandra; Merecz-Kot, Dorota; Andysz, Aleksandra

    2015-01-01

    Managers influence the way organization works as well as the functioning of subordinates - in the context of their work life but non-professional functioning as well e.g., attitude towards work-life balance or taking care of health. We focused on the superior-subordinate relation, referring to social power bases theory by Raven. We identified the reasons why subordinates decide to follow their superiors' orders and determined specific styles of compliance with superiors' will. Understanding why employees listen to their superiors may be valuable in the context of supporting healthy organizational climate and atmosphere of co-operation or communicating values - for example, as regards taking care of own health. We discussed the results referring to the issue of influencing employees in the context of their health behavior. The research involved 100 Polish employees, aged 28 years old on average, who filled in the Interpersonal Power Inventory by Raven et al. for subordinates in a Polish adaptation by Zaleski. The questionnaire includes 11 subscales referring to power bases. Based on the cluster analysis results, we recognized people who complied because of: all kinds of power bases (typical for 46% of the respondents); the respect for superiors' professionalism (34%); and formal/objective reasons (20%). Employees differ in terms of their styles of compliance. Their motives to comply with superiors' instructions constitute compilations of power bases. The superiors' awareness of the reasons why their employees decide to follow orders is necessary for successful management. It may motivate employees to work but also to take care of their own health. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  20. Intravascular Ultrasound Imaging of Peripheral Arteries as an Adjunct to Balloon Angioplasty and Atherectomy

    International Nuclear Information System (INIS)

    Korogi, Yukunori; Hirai, Toshinori; Takahashi, Mutsumasa

    1996-01-01

    This article reviews many of the applications of intravascular ultrasound (US) imaging for peripheral arterial diseases. In vitro studies demonstrate an excellent correlation between ultrasound measurements of lumen and plaque crossectional area compared with histologic sections. In vivo clinical studies reveal the enhanced diagnostic capabilities of this technology compared with angiography. Intravascular US imaging can provide valuable information on the degree, eccentricity, and histologic type of stenosis before intervention, and on the morphological changes in the arterial wall and the extent of excision after intervention. Intravascular US may also serve as a superior index for gauging the diameter of balloon, stent, laser probe, and/or atherectomy catheter appropriate for a proposed intervention. Significant new insights into the mechanisms of balloon angioplasty and atherectomy have been established by intravascular US findings. Intravascular US imaging has been shown to be a more accurate method than angiography for determining the cross-sectional area of the arterial lumen, and for assessing severity of stenosis. Quantitative assessment of the luminal cross-sectional area after the balloon dilatation should be more accurate than angiography as intimal tears or dissections produced by the dilatation may not be accurately evaluated with angiography. At the present time, intravascular US is still a controversial imaging technique. Outcome studies are currently being organized to assess the clinical value and cost effectiveness of intravascular ultrasound in the context of these interventional procedures

  1. Capabilities of seismic and georadar 2D/3D imaging of shallow subsurface of transport route using the Seismobile system

    Science.gov (United States)

    Pilecki, Zenon; Isakow, Zbigniew; Czarny, Rafał; Pilecka, Elżbieta; Harba, Paulina; Barnaś, Maciej

    2017-08-01

    In this work, the capabilities of the Seismobile system for shallow subsurface imaging of transport routes, such as roads, railways, and airport runways, in different geological conditions were presented. The Seismobile system combines the advantages of seismic profiling using landstreamer and georadar (GPR) profiling. It consists of up to four seismic measuring lines and carriage with a suspended GPR antenna. Shallow subsurface recognition may be achieved to a maximum width of 10.5 m for a distance of 3.5 m between the measurement lines. GPR measurement is performed in the axis of the construction. Seismobile allows the measurement time, labour and costs to be reduced due to easy technique of its installation, remote data transmission from geophones to accompanying measuring modules, automated location of the system based on GPS and a highly automated method of seismic wave excitation. In this paper, the results of field tests carried out in different geological conditions were presented. The methodologies of acquisition, processing and interpretation of seismic and GPR measurements were broadly described. Seismograms and its spectrum registered by Seismobile system were compared to the ones registered by Geode seismograph of Geometrix. Seismic data processing and interpretation software allows for the obtaining of 2D/3D models of P- and S-wave velocities. Combined seismic and GPR results achieved sufficient imaging of shallow subsurface to a depth of over a dozen metres. The obtained geophysical information correlated with geological information from the boreholes with good quality. The results of performed tests proved the efficiency of the Seismobile system in seismic and GPR imaging of a shallow subsurface of transport routes under compound conditions.

  2. Flow velocity and volume measurement of superior and inferior mesenteric artery with cine phase contrast magnetic resonance imaging

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Cooper, T.G.; Jenner, G.; Potchen, E.J.; Ishigaki, Takeo.

    1994-01-01

    The flow velocity and volume of the superior and inferior mesenteric arteries (SMA, IMA) were measured with cine phase contrast magnetic resonance (MR) imaging in five healthy volunteers. Each volunteer was first measured in a fasting state, and then one, two, and three hours after a meal. The average SMA flow volume of the volunteers was 230.3±46.8 ml/min (mean±standard error) during the fasting state, and 714.7±207.7 ml/min, 339.2±85.7 ml/min, and 263.8±21.0 ml/min, respectively, at one, two, and three hours postmeal. The increase at one hour postmeal was statistically significant (p<0.05). The corresponding flow measurements in the IMA were 63.1±11.2 ml/min, 67.6±11.2 ml/min, 57.9±8.6 ml/min, and 53.2±6.8 ml/min. These values do not represent a statistically significant flow volume change in the IMA. In all volunteers, the SMA volumetric flow increased the most one hour after the food challenge (72-400% relative to baseline). Diastolic velocity in the SMA increased significantly one hour postmeal, but systolic velocity did not change significantly. The IMA did not demonstrate a significant change in either systolic or diastolic velocity. The difference between the SMA and IMA in the way of reacting against the food challenge is thought to represent the difference between the requirements of small and large intestine for blood supply after the food challenge. These data demonstrate the possibility of this modality for the assessment of conditions such as chronic mesenteric ischemia. (author)

  3. Imaging of the sturge-weber syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Choong Gon; Kim, In One; Kim, Woo Sun; Han, Moon Hee; Moon, Woo Kyung; Chang, Kee Hyun; Yeon, Kyung Mo [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1994-02-15

    The purposes of this article are to illustrate the typical imaging features of eight patients with this syndrome and to discuss the advantage of each imaging modality with a concise review of literatures. We retrospectively reviewed plain skull radiographs, computed tomographic (CT) scans, magnetic resonance (MR) images and cerebral angiograms of eight patients with Sturge-Weber syndrome. We analyzed the radiographic findings of Sturge-Weber syndrome and compared the findings of CT, MR and angiography. Plain radiographs showed characteristic gyriform calcification after 2 years of age. CT scans excellently demonstrated cortical calcifications, prominently enhancing choroid plexi and dilated periventricular veins. MR revealed dilated deep cerebral veins as tubular or spot-like signal void structures at periventricular areas and showed stripes of cortical enhancement after gadolinium infection. Angiography showed dilated tortuous medullary and deep cerebral veins as the collateral pathways of blood shunting. MR was superior to CT in the detection of parenchymal atrophy, venous abnormalities and the extent of angiomatous involvement. Angiography showed enlarged deep cerebral or medullary veins better than MR imaging. We think that each imaging modality including CT, MR or angiography has unique advantages in the diagnosis of this syndrome but MR will be used frequently because of its superior ability for the detection of atrophy, vascular abnormalities and direct visualization of leptomeningeal angiomatosis with contrast enhancement.

  4. Imaging of the sturge-weber syndrome

    International Nuclear Information System (INIS)

    Choi, Choong Gon; Kim, In One; Kim, Woo Sun; Han, Moon Hee; Moon, Woo Kyung; Chang, Kee Hyun; Yeon, Kyung Mo

    1994-01-01

    The purposes of this article are to illustrate the typical imaging features of eight patients with this syndrome and to discuss the advantage of each imaging modality with a concise review of literatures. We retrospectively reviewed plain skull radiographs, computed tomographic (CT) scans, magnetic resonance (MR) images and cerebral angiograms of eight patients with Sturge-Weber syndrome. We analyzed the radiographic findings of Sturge-Weber syndrome and compared the findings of CT, MR and angiography. Plain radiographs showed characteristic gyriform calcification after 2 years of age. CT scans excellently demonstrated cortical calcifications, prominently enhancing choroid plexi and dilated periventricular veins. MR revealed dilated deep cerebral veins as tubular or spot-like signal void structures at periventricular areas and showed stripes of cortical enhancement after gadolinium infection. Angiography showed dilated tortuous medullary and deep cerebral veins as the collateral pathways of blood shunting. MR was superior to CT in the detection of parenchymal atrophy, venous abnormalities and the extent of angiomatous involvement. Angiography showed enlarged deep cerebral or medullary veins better than MR imaging. We think that each imaging modality including CT, MR or angiography has unique advantages in the diagnosis of this syndrome but MR will be used frequently because of its superior ability for the detection of atrophy, vascular abnormalities and direct visualization of leptomeningeal angiomatosis with contrast enhancement

  5. WE-DE-207A-02: Advances in Cone Beam CT Anatomical and Functional Imaging in Angio-Suite to Enable One-Stop-Shop Stroke Imaging Workflow

    Energy Technology Data Exchange (ETDEWEB)

    Chen, G. [University of Wisconsin (United States)

    2016-06-15

    audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens

  6. WE-DE-207A-02: Advances in Cone Beam CT Anatomical and Functional Imaging in Angio-Suite to Enable One-Stop-Shop Stroke Imaging Workflow

    International Nuclear Information System (INIS)

    Chen, G.

    2016-01-01

    audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens

  7. An efficient dictionary learning algorithm and its application to 3-D medical image denoising.

    Science.gov (United States)

    Li, Shutao; Fang, Leyuan; Yin, Haitao

    2012-02-01

    In this paper, we propose an efficient dictionary learning algorithm for sparse representation of given data and suggest a way to apply this algorithm to 3-D medical image denoising. Our learning approach is composed of two main parts: sparse coding and dictionary updating. On the sparse coding stage, an efficient algorithm named multiple clusters pursuit (MCP) is proposed. The MCP first applies a dictionary structuring strategy to cluster the atoms with high coherence together, and then employs a multiple-selection strategy to select several competitive atoms at each iteration. These two strategies can greatly reduce the computation complexity of the MCP and assist it to obtain better sparse solution. On the dictionary updating stage, the alternating optimization that efficiently approximates the singular value decomposition is introduced. Furthermore, in the 3-D medical image denoising application, a joint 3-D operation is proposed for taking the learning capabilities of the presented algorithm to simultaneously capture the correlations within each slice and correlations across the nearby slices, thereby obtaining better denoising results. The experiments on both synthetically generated data and real 3-D medical images demonstrate that the proposed approach has superior performance compared to some well-known methods. © 2011 IEEE

  8. Aging and the Picture Superiority Effect in Recall.

    Science.gov (United States)

    Winograd, Eugene; And Others

    1982-01-01

    Compared verbal and visual encoding using the picture superiority effect. One experiment found an interaction between age and type of material. In other experiments, the picture superiority effect was found in both age groups with no interaction. Performing a semantic-orienting task had no effect on recall. (Author/RC)

  9. Fatal pericardial tamponade after superior vena cava stenting.

    NARCIS (Netherlands)

    Ploegmakers, M.J.M.; Rutten, M.J.C.M.

    2009-01-01

    We discuss a fatal complication of percutaneous superior vena cava (SVC) self-expandable stent placement in a patient with superior vena cava syndrome (SVCS). The SVCS was caused by a malignant mediastinal mass with total occlusion of the SVC. Twenty-four hours after the procedure, the patient died

  10. Imaging of the temporomandibular joint: An update

    Institute of Scientific and Technical Information of China (English)

    Asim; K; Bag; Santhosh; Gaddikeri; Aparna; Singhal; Simms; Hardin; Benson; D; Tran; Josue; A; Medina; Joel; K; Curé

    2014-01-01

    Imaging of the temporomandibular joint(TMJ) is continuously evolving with advancement of imaging technologies. Many different imaging modalities are currently used to evaluate the TMJ. Magnetic resonance imaging is commonly used for evaluation of the TMJ due to its superior contrast resolution and its ability to acquire dynamic imaging for demonstration of the functionality of the joint. Computed tomography and ultrasound imaging have specific indication in imaging of the TMJ. This article focuses on state of the art imaging of the temporomandibular joint. Relevant normal anatomy and biomechanics of movement of the TMJ are discussed for better understanding of many TMJ pathologies. Imaging of internal derangements is discussed in detail. Different arthropathies and commontumors are also discussed in this article.

  11. Rights, goals, and capabilities

    NARCIS (Netherlands)

    van Hees, M.V.B.P.M

    This article analyses the relationship between rights and capabilities in order to get a better grasp of the kind of consequentialism that the capability theory represents. Capability rights have been defined as rights that have a capability as their object (rights to capabilities). Such a

  12. Three-dimensional imaging of lumbar spinal fusions

    International Nuclear Information System (INIS)

    Chafetz, N.; Hunter, J.C.; Cann, C.E.; Morris, J.M.; Ax, L.; Catterling, K.F.

    1986-01-01

    Using a Cemax 1000 three-dimensional (3D) imaging computer/workstation, the author evaluated 15 patients with lumbar spinal fusions (four with pseudarthrosis). Both axial images with sagittal and coronal reformations and 3D images were obtained. The diagnoses (spinal stenosis and psuedarthrosis) were changed in four patients, confirmed in six patients, and unchanged in five patients with the addition of the 3D images. The ''cut-away'' 3D images proved particularly helpful for evaluation of central and lateral spinal stenosis, whereas the ''external'' 3D images were most useful for evaluation of the integrity of the fusion. Additionally, orthopedic surgeons found 3D images superior for both surgical planning and explaining pathology to patients

  13. The picture superiority effect in a cross-modality recognition task.

    Science.gov (United States)

    Stenbert, G; Radeborg, K; Hedman, L R

    1995-07-01

    Words and pictures were studied and recognition tests given in which each studied object was to be recognized in both word and picture format. The main dependent variable was the latency of the recognition decision. The purpose was to investigate the effects of study modality (word or picture), of congruence between study and test modalities, and of priming resulting from repeated testing. Experiments 1 and 2 used the same basic design, but the latter also varied retention interval. Experiment 3 added a manipulation of instructions to name studied objects, and Experiment 4 deviated from the others by presenting both picture and word referring to the same object together for study. The results showed that congruence between study and test modalities consistently facilitated recognition. Furthermore, items studied as pictures were more rapidly recognized than were items studied as words. With repeated testing, the second instance was affected by its predecessor, but the facilitating effect of picture-to-word priming exceeded that of word-to-picture priming. The finds suggest a two- stage recognition process, in which the first is based on perceptual familiarity and the second uses semantic links for a retrieval search. Common-code theories that grant privileged access to the semantic code for pictures or, alternatively, dual-code theories that assume mnemonic superiority for the image code are supported by the findings. Explanations of the picture superiority effect as resulting from dual encoding of pictures are not supported by the data.

  14. Spontaneous Superior Mesenteric Artery Branch Pseudoaneurysm: A Rare Case Report

    Directory of Open Access Journals (Sweden)

    Mina Guirgis

    Full Text Available : Background: Visceral arterial pseudoaneurysms (VAPAs are rare vascular entities with serious consequences. Traditionally, they are associated with trauma, infection, and inflammatory disease, or they can arise as a post-operative complication. Report: An 87 year old man presented with abdominal pain and was found to have a spontaneous VAPA on a computed tomography angiogram. Serial imaging 4 months previously had demonstrated no aneurysm. Between scans, warfarin was changed to apixaban for aortic valve replacement, but he had no other changes to any other medications. He required urgent endovascular coiling of the pseudoaneurysm, with satisfactory recovery and outcome. Discussion: VAPAs are extremely rare, with splenic artery VAPAs the most commonly reported. Regardless, fewer than 250 cases of splenic artery pseudoaneurysm have been reported. Superior mesenteric artery (SMA pseudoaneurysms are the rarest type of VAPAs. Early identification and urgent treatment are warranted because of the associated high mortality risk, with a 50% risk of rupture in any given VAPA. Treatment options range from open operation to endoscopic and endovascular procedures. Apixaban has been proposed to contribute to pseudoaneurysm formation by slow and continuous bleeding that results in the formation of the pseudoaneurysm. Conclusions: Spontaneous VAPAs are extremely rare and this is the first time a VAPA has been associated with the novel oral anticoagulant “apixaban”. Urgent management of any VAPAs is important because of the high risk of rupture and potential life threatening haemorrhage. Keywords: Visceral arterial pseudoaneurysm, Superior mesenteric artery, Apixaban, Coils

  15. Image Analysis for X-ray Imaging of Food

    DEFF Research Database (Denmark)

    Einarsdottir, Hildur

    for quality and safety evaluation of food products. In this effort the fields of statistics, image analysis and statistical learning are combined, to provide analytical tools for determining the aforementioned food traits. The work demonstrated includes a quantitative analysis of heat induced changes......X-ray imaging systems are increasingly used for quality and safety evaluation both within food science and production. They offer non-invasive and nondestructive penetration capabilities to image the inside of food. This thesis presents applications of a novel grating-based X-ray imaging technique...... and defect detection in food. Compared to the complex three dimensional analysis of microstructure, here two dimensional images are considered, making the method applicable for an industrial setting. The advantages obtained by grating-based imaging are compared to conventional X-ray imaging, for both foreign...

  16. Various advanced capabilities of the RBS setup at IMEC

    International Nuclear Information System (INIS)

    Brijs, B.; Coster, W. de; Vandervorst, W.

    1992-01-01

    This article describes the various capabilities of the ion-beam analysis facility at IMEC which is designed to fulfill two needs. One is the high volume analysis service of material originating from the processing and material development groups at IMEC and the other is the research associated with gaining improved insight in the different analysis methods used for semiconductors, in particular all the aspects related with ion sputtering, and the development of improved analysis capabilities in order to cope with the demands from the analysis service. The latter includes the incorporation of a TOF spectrometer for heavy-ion RBS and ERD, the investigation towards the application of heavy-ion RBS for improved sensitivity, the application of angle resolved image scans for fast and certified channeling analysis and resonant analysis by automated energy scanning. (orig.)

  17. Potential dependent superiority of gold nanoparticles in comparison to iodinated contrast agents

    International Nuclear Information System (INIS)

    Jackson, Price A.; Rahman, Wan Nordiana W. Abd.; Wong, Christopher J.; Ackerly, Trevor; Geso, Moshi

    2010-01-01

    Purpose: To identify the benefits in image contrast enhancement using gold nanoparticles (AuNPs) compared to conventional iodinated contrast media. Materials and methods: Gold nanoparticles and iodinated contrast media were evaluated for contrast enhancement at various X-ray tube potentials in an imaging phantom. Iopromide and AuNP suspension were equalized according to molar concentration of radiopaque element (0.5077 Mol/L). Contrast-to-noise ratio is used to quantify contrast enhancement. Both projectional radiographic (40-80 kVp) and computed tomography (CT) (80-140kVp) imaging modalities were examined. Results and conclusions: Findings indicate 89% improvement in CNR at low energies near the mammographic range (40 kVp). However, as expected no significant difference in enhancement was observed at potentials commonly used for angiography (around 80 kVp) probably due to the k-edge influence for iodine. At the highest energies typically available in computed tomography, significant improvement in contrast enhancement using gold nanoparticles is obtained, 114% greater CNR than that produced by iodine at 140 kVp. Experimental findings for 70-120 kVp spectra correlate well with the theoretical calculations based on linear attenuation coefficients. Superior attenuation of gold nanoparticles at low and high kVp potentials support their further (pre)clinical evaluation.

  18. Multimodal quantitative phase and fluorescence imaging of cell apoptosis

    Science.gov (United States)

    Fu, Xinye; Zuo, Chao; Yan, Hao

    2017-06-01

    Fluorescence microscopy, utilizing fluorescence labeling, has the capability to observe intercellular changes which transmitted and reflected light microscopy techniques cannot resolve. However, the parts without fluorescence labeling are not imaged. Hence, the processes simultaneously happen in these parts cannot be revealed. Meanwhile, fluorescence imaging is 2D imaging where information in the depth is missing. Therefore the information in labeling parts is also not complete. On the other hand, quantitative phase imaging is capable to image cells in 3D in real time through phase calculation. However, its resolution is limited by the optical diffraction and cannot observe intercellular changes below 200 nanometers. In this work, fluorescence imaging and quantitative phase imaging are combined to build a multimodal imaging system. Such system has the capability to simultaneously observe the detailed intercellular phenomenon and 3D cell morphology. In this study the proposed multimodal imaging system is used to observe the cell behavior in the cell apoptosis. The aim is to highlight the limitations of fluorescence microscopy and to point out the advantages of multimodal quantitative phase and fluorescence imaging. The proposed multimodal quantitative phase imaging could be further applied in cell related biomedical research, such as tumor.

  19. Development of an ESR/MR dual-imaging system as a tool to detect bioradicals

    International Nuclear Information System (INIS)

    Fujii, Hirotada; Aoki, Masaaki; Haishi, Tomoyuki; Itoh, Kouichi; Sakata, Motomichi

    2006-01-01

    A system combining electron spin resonance imaging (ESRI) with another imaging modality capable of enabling visualization of the distribution of bioradicals on an anatomical map of the specimens would be a superior biomedical imaging system. We describe the development of an electron spin resonance ESR/MR dual-imaging system with one permanent magnet and the biomedical applications of this system. The magnetic circuit developed for the ESR/MR dual-imaging system consisted of the permanent magnet made of Fe-Nd-B, pole pieces, and poke. The permanent magnet was installed on the MR side only, and the ESR side was made of pole pieces only. The magnetic field was adjusted to 0.5T at MR and to 0.042T at ESR. The overall dimensions of the magnet developed for the ESR/MR imaging system were 460 (W) x 440 (D) x 460 (H) mm, and it weighed 220 kg. The distance of each center for the magnet for ESR and MR imaging could be set as close as 200 mm. The entire ESR/MR imaging system can be installed in a common laboratory without magnetic shielding. MR images of plants (myoga) and small animals (mice and rats) were successfully acquired with or without ESR operation. ESR spectra of nitroxyl spin probes were also measured, even with MRI operation. ESR signals of triarylmethyl derivatives with narrow line-width (0.026 mT) were observed in living mice while MRI was operating. The ESR/MR imaging dual functions work properly with no electric or magnetic interference. The ESR/MR dual images demonstrate that this system enables visualization of the distribution of bioradicals on the anatomical map of the object. (author)

  20. Inspection of copper canisters for spent nuclear fuel by means of ultrasound. Nonlinear acoustics, synthetic aperture imaging

    International Nuclear Information System (INIS)

    Lingvall, Fredrik; Ping Wu; Stepinski, Tadeusz

    2003-03-01

    This report contains results concerning inspection of copper canisters for spent nuclear fuel by means of ultrasound obtained at Signals and Systems, Uppsala University in year 2001/2002. The first chapter presents results of an investigation of a new method for synthetic aperture imaging. The new method presented here takes the form of a 2D filter based on minimum mean squared error (MMSE) criteria. The filter, which varies with the target position in two dimensions includes information about spatial impulse response (SIR) of the imaging system. Spatial resolution of the MMSE method is investigated and compared experimentally to that of the classical SAFT and phased array imaging. It is shown that the resolution of the MMSE algorithm, evaluated for imaging immersed copper specimen is superior to that observed for the two above-mentioned methods. Extended experimental and theoretical research concerning the potential of nonlinear waves and material harmonic imaging is presented in the second chapter. An experimental work is presented that was conducted using the RITEC RAM-5000 ultrasonic system capable of providing a high power tone-burst output. A new method for simulation of nonlinear acoustic waves that is a combination of the angular spectrum approach and the Burger's equation is also presented. This method was used for simulating nonlinear elastic waves radiated by the annular transducer that was used in the experiments

  1. Inspection of copper canisters for spent nuclear fuel by means of ultrasound. Nonlinear acoustics, synthetic aperture imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lingvall, Fredrik; Ping Wu; Stepinski, Tadeusz [Uppsala Univ., (Sweden). Dept. of Materials Science

    2003-03-01

    This report contains results concerning inspection of copper canisters for spent nuclear fuel by means of ultrasound obtained at Signals and Systems, Uppsala University in year 2001/2002. The first chapter presents results of an investigation of a new method for synthetic aperture imaging. The new method presented here takes the form of a 2D filter based on minimum mean squared error (MMSE) criteria. The filter, which varies with the target position in two dimensions includes information about spatial impulse response (SIR) of the imaging system. Spatial resolution of the MMSE method is investigated and compared experimentally to that of the classical SAFT and phased array imaging. It is shown that the resolution of the MMSE algorithm, evaluated for imaging immersed copper specimen is superior to that observed for the two above-mentioned methods. Extended experimental and theoretical research concerning the potential of nonlinear waves and material harmonic imaging is presented in the second chapter. An experimental work is presented that was conducted using the RITEC RAM-5000 ultrasonic system capable of providing a high power tone-burst output. A new method for simulation of nonlinear acoustic waves that is a combination of the angular spectrum approach and the Burger's equation is also presented. This method was used for simulating nonlinear elastic waves radiated by the annular transducer that was used in the experiments.

  2. Analysis and clinical usefullness of cardiac ECT images

    International Nuclear Information System (INIS)

    Hayashi, Makoto; Kagawa, Masaaki; Yamada, Yukinori

    1983-01-01

    We estimated basically and clinically myocardial ECT image and ECG gated cardiac blood-pool ECT image. ROC curve is used for the evaluation of the accuracy in diagnostic myocardial infarction. The accuracy in diagnostic of MI is superior in myocardial ECT image and ECT estimation is unnecessary skillfulness and experience. We can absene the whole defect of MI than planar image by using ECT. LVEDV between estimated volume and contrast volume is according to it and get one step for automatic analysis of cardiac volume. (author)

  3. Capability ethics

    NARCIS (Netherlands)

    I.A.M. Robeyns (Ingrid)

    2012-01-01

    textabstractThe capability approach is one of the most recent additions to the landscape of normative theories in ethics and political philosophy. Yet in its present stage of development, the capability approach is not a full-blown normative theory, in contrast to utilitarianism, deontological

  4. Imaging of acquired non-traumatic cochlear lesions: iconographic essay

    International Nuclear Information System (INIS)

    Garcia, Marcelo de Mattos; Gonzaga, Juliana Gontijo

    2006-01-01

    Different non-traumatic acquired cochlear lesions are shown in this article with imaging methods. They may be responsible for neuro sensorial hearing loss or vertigo. The method of choice is computed tomography when evaluating the osseous labyrinth whereas magnetic resonance imaging has superior resolution in the studies of the membranaceous labyrinth. (author)

  5. Globalització i internacionalització en l'ensenyament superior

    OpenAIRE

    de Wit, J.W.M (Hans)

    2011-01-01

    La internacionalització és un fenomen cada cop més important i generalitzat en l'ensenyament superior en els àmbits institucional, nacional i internacional. La globalització de les nostres economies i societats ha tingut un impacte en l'ensenyament superior dels últims vint-i-cinc anys, i el mateix ensenyament superior s'ha convertit en un actor en l'economia de coneixement global, en la recerca i en altres àrees que impliquen aspectes com la c...

  6. SU-E-I-51: Use of Blade Sequences in Cervical Spine MR Imaging for Eliminating Motion, Truncation and Flow Artifacts

    Energy Technology Data Exchange (ETDEWEB)

    Mavroidis, P [University of Texas Health Science Center, UTHSCSA, San Antonio, TX (United States); Lavdas, E; Kostopoulos, S; Ninos, C; Strikou, A; Glotsos, D; Vlachopoulou, A; Oikonomou, G [Technological Education Institute of Athens, Athens, Athens (Greece); Economopoulos, N [General University Hospital ATTIKON, Athens, Athens (Greece); Roka, V [Health Center of Farkadona, Trikala (Greece); Sakkas, G [Center for Research and Technology of Thessaly, Trikala (Greece); Tsagkalis, A; Batsikas, G [IASO Thessalias Hospital, Larissa (Greece); Statkahis, S [Cancer Therapy and Research Center, San Antonio, TX (United States); Papanikolaou, N [University of Texas HSC SA, San Antonio, TX (United States)

    2014-06-01

    Purpose: To assess the efficacy of the BLADE technique to eliminate motion, truncation, flow and other artifacts in Cervical Spine MRI compared to the conventional technique. To study the ability of the examined sequences to reduce the indetention and wrap artifacts, which have been reported in BLADE sagittal sequences. Methods: Forty consecutive subjects, who had been routinely scanned for cervical spine examination using four different image acquisition techniques, were analyzed. More specifically, the following pairs of sequences were compared: a) T2 TSE SAG vs. T2 TSE SAG BLADE and b) T2 TIRM SAG vs. T2 TIRM SAG BLADE. A quantitative analysis was performed using the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and relative contrast (ReCon) measures. A qualitative analysis was also performed by two radiologists, who graded seven image characteristics on a 5-point scale (0:non-visualization; 1:poor; 2:average; 3:good; 4:excellent). The observers also evaluated the presence of image artifacts (motion, truncation, flow, indentation). Results: Based on the findings of the quantitative analysis, the ReCON values of the CSF (cerebrospinal fluid)/SC (spinal cord) between TIRM SAG and TIRM SAG BLADE were found to present statistical significant differences (p<0.001). Regarding motion and truncation artifacts, the T2 TSE SAG BLADE was superior compared to the T2 TSE SAG and the T2 TIRM SAG BLADE was superior compared to the T2 TIRM SAG. Regarding flow artifacts, T2 TIRM SAG BLADE eliminated more artifacts compared to the T2 TIRM SAG. Conclusion: The use of BLADE sequences in cervical spine MR examinations appears to be capable of potentially eliminating motion, pulsatile flow and trancation artifacts. Furthermore, BLADE sequences are proposed to be used in the standard examination protocols based on the fact that a significantly improved image quality could be achieved.

  7. SU-E-I-51: Use of Blade Sequences in Cervical Spine MR Imaging for Eliminating Motion, Truncation and Flow Artifacts

    International Nuclear Information System (INIS)

    Mavroidis, P; Lavdas, E; Kostopoulos, S; Ninos, C; Strikou, A; Glotsos, D; Vlachopoulou, A; Oikonomou, G; Economopoulos, N; Roka, V; Sakkas, G; Tsagkalis, A; Batsikas, G; Statkahis, S; Papanikolaou, N

    2014-01-01

    Purpose: To assess the efficacy of the BLADE technique to eliminate motion, truncation, flow and other artifacts in Cervical Spine MRI compared to the conventional technique. To study the ability of the examined sequences to reduce the indetention and wrap artifacts, which have been reported in BLADE sagittal sequences. Methods: Forty consecutive subjects, who had been routinely scanned for cervical spine examination using four different image acquisition techniques, were analyzed. More specifically, the following pairs of sequences were compared: a) T2 TSE SAG vs. T2 TSE SAG BLADE and b) T2 TIRM SAG vs. T2 TIRM SAG BLADE. A quantitative analysis was performed using the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and relative contrast (ReCon) measures. A qualitative analysis was also performed by two radiologists, who graded seven image characteristics on a 5-point scale (0:non-visualization; 1:poor; 2:average; 3:good; 4:excellent). The observers also evaluated the presence of image artifacts (motion, truncation, flow, indentation). Results: Based on the findings of the quantitative analysis, the ReCON values of the CSF (cerebrospinal fluid)/SC (spinal cord) between TIRM SAG and TIRM SAG BLADE were found to present statistical significant differences (p<0.001). Regarding motion and truncation artifacts, the T2 TSE SAG BLADE was superior compared to the T2 TSE SAG and the T2 TIRM SAG BLADE was superior compared to the T2 TIRM SAG. Regarding flow artifacts, T2 TIRM SAG BLADE eliminated more artifacts compared to the T2 TIRM SAG. Conclusion: The use of BLADE sequences in cervical spine MR examinations appears to be capable of potentially eliminating motion, pulsatile flow and trancation artifacts. Furthermore, BLADE sequences are proposed to be used in the standard examination protocols based on the fact that a significantly improved image quality could be achieved

  8. High-resolution ultrasound imaging and noninvasive optoacoustic monitoring of blood variables in peripheral blood vessels

    Science.gov (United States)

    Petrov, Irene Y.; Petrov, Yuriy; Prough, Donald S.; Esenaliev, Rinat O.

    2011-03-01

    Ultrasound imaging is being widely used in clinics to obtain diagnostic information non-invasively and in real time. A high-resolution ultrasound imaging platform, Vevo (VisualSonics, Inc.) provides in vivo, real-time images with exceptional resolution (up to 30 microns) using high-frequency transducers (up to 80 MHz). Recently, we built optoacoustic systems for probing radial artery and peripheral veins that can be used for noninvasive monitoring of total hemoglobin concentration, oxyhemoglobin saturation, and concentration of important endogenous and exogenous chromophores (such as ICG). In this work we used the high-resolution ultrasound imaging system Vevo 770 for visualization of the radial artery and peripheral veins and acquired corresponding optoacoustic signals from them using the optoacoustic systems. Analysis of the optoacoustic data with a specially developed algorithm allowed for measurement of blood oxygenation in the blood vessels as well as for continuous, real-time monitoring of arterial and venous blood oxygenation. Our results indicate that: 1) the optoacoustic technique (unlike pure optical approaches and other noninvasive techniques) is capable of accurate peripheral venous oxygenation measurement; and 2) peripheral venous oxygenation is dependent on skin temperature and local hemodynamics. Moreover, we performed for the first time (to the best of our knowledge) a comparative study of optoacoustic arterial oximetry and a standard pulse oximeter in humans and demonstrated superior performance of the optoacoustic arterial oximeter, in particular at low blood flow.

  9. A single-image method of aberration retrieval for imaging systems under partially coherent illumination

    International Nuclear Information System (INIS)

    Xu, Shuang; Liu, Shiyuan; Zhang, Chuanwei; Wei, Haiqing

    2014-01-01

    We propose a method for retrieving small lens aberrations in optical imaging systems under partially coherent illumination, which only requires to measure one single defocused image of intensity. By deriving a linear theory of imaging systems, we obtain a generalized formulation of aberration sensitivity in a matrix form, which provides a set of analytic kernels that relate the measured intensity distribution directly to the unknown Zernike coefficients. Sensitivity analysis is performed and test patterns are optimized to ensure well-posedness of the inverse problem. Optical lithography simulations have validated the theoretical derivation and confirmed its simplicity and superior performance in retrieving small lens aberrations. (fast track communication)

  10. Dynamic Capabilities

    DEFF Research Database (Denmark)

    Grünbaum, Niels Nolsøe; Stenger, Marianne

    2013-01-01

    The findings reveal a positive relationship between dynamic capabilities and innovation performance in the case enterprises, as we would expect. It was, however, not possible to establish a positive relationship between innovation performance and profitability. Nor was there any positive...... relationship between dynamic capabilities and profitability....

  11. Superior Mesenteric Artery Syndrome: An Infrequent Complication of Scoliosis Surgery

    Directory of Open Access Journals (Sweden)

    Metin Keskin

    2014-01-01

    Full Text Available Superior mesenteric artery syndrome is a rare condition that causes a proximal small intestinal obstruction due to contraction of the angle between the superior mesenteric artery and the aorta. Scoliosis surgery is one of the 15 reasons for superior mesenteric artery syndrome, which can present with acute or chronic manifestations. Although conservative treatment is usually possible, surgical treatment is required in certain cases that cannot be treated using conservative methods. In this paper, we describe a patient who developed superior mesenteric artery syndrome after scoliosis surgery and was treated with duodenojejunostomy due to failure and complications of conservative treatment.

  12. Stokes image reconstruction for two-color microgrid polarization imaging systems.

    Science.gov (United States)

    Lemaster, Daniel A

    2011-07-18

    The Air Force Research Laboratory has developed a new microgrid polarization imaging system capable of simultaneously reconstructing linear Stokes parameter images in two colors on a single focal plane array. In this paper, an effective method for extracting Stokes images is presented for this type of camera system. It is also shown that correlations between the color bands can be exploited to significantly increase overall spatial resolution. Test data is used to show the advantages of this approach over bilinear interpolation. The bounds (in terms of available reconstruction bandwidth) on image resolution are also provided.

  13. Superior dislocation hip with anterior column acetabular fracture ...

    African Journals Online (AJOL)

    Superior variety of anterior dislocation of the hip is a rare injury. Its occurrence with acetabular fractures has been documented infrequently. We report a case of superior dislocation of the hip with anterior column acetabular fracture. Open reduction of the hip and internal fixation of the fracture was carried out using a twin ...

  14. Superior mesenteric artery syndrome: case report | Jani | East ...

    African Journals Online (AJOL)

    Superior Mesenteric Artery Syndrome (SMAS) is caused by trapping of the third part of the duodenum between Superior Mesenteric Artery (SMA) and aorta as result of narrowing of the angle between the two vessels due to acute loss of mesenteric fat which is secondary to rapid weight loss. A fifteen year old caucasian ...

  15. Capabilities and Incapabilities of the Capabilities Approach to Health Justice.

    Science.gov (United States)

    Selgelid, Michael J

    2016-01-01

    This first part of this article critiques Sridhar Venkatapuram's conception of health as a capability. It argues that Venkatapuram relies on the problematic concept of dignity, implies that those who are unhealthy lack lives worthy of dignity (which seems politically incorrect), sets a low bar for health, appeals to metaphysically problematic thresholds, fails to draw clear connections between appealed-to capabilities and health, and downplays the importance/relevance of health functioning. It concludes by questioning whether justice entitlements should pertain to the capability for health versus health achievements, challenging Venkatapuram's claims about the strength of health entitlements, and demonstrating that the capabilities approach is unnecessary to address social determinants of health. © 2016 John Wiley & Sons Ltd.

  16. Signal-to-noise ratio analysis and evaluation of the Hadamard imaging technique

    Science.gov (United States)

    Jobson, D. J.; Katzberg, S. J.; Spiers, R. B., Jr.

    1977-01-01

    The signal-to-noise ratio performance of the Hadamard imaging technique is analyzed and an experimental evaluation of a laboratory Hadamard imager is presented. A comparison between the performances of Hadamard and conventional imaging techniques shows that the Hadamard technique is superior only when the imaging objective lens is required to have an effective F (focus) number of about 2 or slower.

  17. [Neuromolecular mechanism of the superiority illusion].

    Science.gov (United States)

    Yamada, Makiko

    2014-01-01

    The majority of individuals evaluate themselves as above average. This is a cognitive bias called "the superiority illusion". This illusory self-evaluation helps us to have hopes for the future, and has been central to the process of human evolution. Possessing this illusion is also important for mental health, as depressed people appear to have a more realistic perception of themselves, dubbed "depressive realism". Our recent study revealed the spontaneous brain activity and central dopaminergic neurotransmission that generate this illusion, using resting-state fMRI and PET. A functional connectivity between the frontal cortex and striatum, regulated by inhibitory dopaminergic neurotransmission, determines individual levels of the superiority illusion. We further revealed that blocking the dopamine transporter, which enhanced the level of dopamine, increased the degree of the superiority illusion. These findings suggest that dopamine acts on striatal dopamine receptors to suppress fronto-striatal functional connectivity, leading to disinhibited, heuristic, approaches to positive self-evaluation. These findings help us to understand how this key aspect of the human mind is biologically determined, and will suggest treatments for depressive symptoms by targeting specific molecules and neural circuits.

  18. Altered microstructural connectivity of the superior cerebellar peduncle is related to motor dysfunction in children with autistic spectrum disorders.

    Science.gov (United States)

    Hanaie, Ryuzo; Mohri, Ikuko; Kagitani-Shimono, Kuriko; Tachibana, Masaya; Azuma, Junji; Matsuzaki, Junko; Watanabe, Yoshiyuki; Fujita, Norihiko; Taniike, Masako

    2013-10-01

    Many studies have reported motor impairments in autistic spectrum disorders (ASD). However, the brain mechanism underlying motor impairment in ASD remains unclear. Recent neuroimaging studies have suggested that underconnectivity between the cerebellum and other brain regions contributes to the features of ASD. In this study, we investigated the microstructural integrity of the cerebellar pathways, including the superior, middle, and inferior cerebellar peduncles, of children with and without ASD by using diffusion tensor imaging (DTI) tractography to determine whether the microstructural integrity of the cerebellar pathways is related to motor function in children with ASD. Thirteen children with ASD and 11 age-, gender-, handedness-, and IQ-matched typically developing (TD) controls were enrolled in this study. DTI outcome measurements, such as fractional anisotropy (FA), axial diffusivity (AD), and radial diffusivity (RD), for the cerebellar pathways were calculated. The Movement Assessment Battery for Children 2 (M-ABC 2) was used for assessing motor functions. There were no significant differences between the two groups in RD. However, compared to the TD subjects, patients with ASD had a significantly lower FA in the right superior cerebellar peduncle and lower AD in the left superior cerebellar peduncle, in addition to a significantly lower score in ball skills and the total test score of M-ABC 2. There was a significant positive correlation between the total test score of M-ABC 2 and FA in the right superior cerebellar peduncle in the ASD group. These findings suggest that the altered microstructural integrity of the superior cerebellar peduncle may be related to motor impairment in ASD.

  19. Biomechanical Effects of Acromioplasty on Superior Capsule Reconstruction for Irreparable Supraspinatus Tendon Tears.

    Science.gov (United States)

    Mihata, Teruhisa; McGarry, Michelle H; Kahn, Timothy; Goldberg, Iliya; Neo, Masashi; Lee, Thay Q

    2016-01-01

    Acromioplasty is increasingly being performed for both reparable and irreparable rotator cuff tears. However, acromioplasty may destroy the coracoacromial arch, including the coracoacromial ligament, consequently causing a deterioration in superior stability even after superior capsule reconstruction. The purpose of this study was to investigate the effects of acromioplasty on shoulder biomechanics after superior capsule reconstruction for irreparable supraspinatus tendon tears. The hypothesis was that acromioplasty with superior capsule reconstruction would decrease the area of subacromial impingement without increasing superior translation and subacromial contact pressure. Controlled laboratory study. Seven fresh-frozen cadaveric shoulders were evaluated using a custom shoulder testing system. Glenohumeral superior translation, the location of the humeral head relative to the glenoid, and subacromial contact pressure and area were compared among 4 conditions: (1) intact shoulder, (2) irreparable supraspinatus tendon tear, (3) superior capsule reconstruction without acromioplasty, and (4) superior capsule reconstruction with acromioplasty. Superior capsule reconstruction was performed using the fascia lata. Compared with the intact shoulder, the creation of an irreparable supraspinatus tear significantly shifted the humeral head superiorly in the balanced muscle loading condition (without superior force applied) (0° of abduction: 2.8-mm superior shift [P = .0005]; 30° of abduction: 1.9-mm superior shift [P = .003]) and increased both superior translation (0° of abduction: 239% of intact [P = .04]; 30° of abduction: 199% of intact [P = .02]) and subacromial peak contact pressure (0° of abduction: 308% of intact [P = .0002]; 30° of abduction: 252% of intact [P = .001]) by applying superior force. Superior capsule reconstruction without acromioplasty significantly decreased superior translation (0° of abduction: 86% of intact [P = .02]; 30° of abduction: 75

  20. Hollow-in-Hollow Carbon Spheres for Lithium-ion Batteries with Superior Capacity and Cyclic Performance

    International Nuclear Information System (INIS)

    Zang, Jun; Ye, Jianchuan; Fang, Xiaoliang; Zhang, Xiangwu; Zheng, Mingsen; Dong, Quanfeng

    2015-01-01

    Highlights: • Hollow-in-hollow structured HIHCS was synthesized via a facile templating strategy. • The HCS core and hollow carbon shell constitute the hollow-in-hollow structure. • The HIHCS exhibited superior rate capability and cycle stability as anode material. • The excellent performance is attributed to the unique hollow-in-hollow structure. - Abstract: Hollow spheres structured materials have been intensively pursued due to their unique properties for energy storage. In this paper, hollow-in-hollow carbon spheres (HIHCS) with a multi-shelled structure were successfully synthesized using a facile hard-templating procedure. When evaluated as anode material for lithium-ion batteries, the resultant HIHCS anode exhibited superior capacity and cycling stability than HCS. It could deliver reversible capacities of 937, 481, 401, 304 and 236 mAh g −1 at current densities of 0.1 A g −1 , 1 A g −1 , 2 A g −1 , 5 A g −1 and 10 A g −1 , respectively. And capacity fading is not apparent in 500 cycles at 5 A g −1 . The excellent performance of the HIHCS anode is ascribed to its unique hollow-in-hollow structure and high specific surface area.

  1. Capabilities for Strategic Adaptation

    DEFF Research Database (Denmark)

    Distel, Andreas Philipp

    This dissertation explores capabilities that enable firms to strategically adapt to environmental changes and preserve competitiveness over time – often referred to as dynamic capabilities. While dynamic capabilities being a popular research domain, too little is known about what these capabiliti...

  2. Robust generative asymmetric GMM for brain MR image segmentation.

    Science.gov (United States)

    Ji, Zexuan; Xia, Yong; Zheng, Yuhui

    2017-11-01

    Accurate segmentation of brain tissues from magnetic resonance (MR) images based on the unsupervised statistical models such as Gaussian mixture model (GMM) has been widely studied during last decades. However, most GMM based segmentation methods suffer from limited accuracy due to the influences of noise and intensity inhomogeneity in brain MR images. To further improve the accuracy for brain MR image segmentation, this paper presents a Robust Generative Asymmetric GMM (RGAGMM) for simultaneous brain MR image segmentation and intensity inhomogeneity correction. First, we develop an asymmetric distribution to fit the data shapes, and thus construct a spatial constrained asymmetric model. Then, we incorporate two pseudo-likelihood quantities and bias field estimation into the model's log-likelihood, aiming to exploit the neighboring priors of within-cluster and between-cluster and to alleviate the impact of intensity inhomogeneity, respectively. Finally, an expectation maximization algorithm is derived to iteratively maximize the approximation of the data log-likelihood function to overcome the intensity inhomogeneity in the image and segment the brain MR images simultaneously. To demonstrate the performances of the proposed algorithm, we first applied the proposed algorithm to a synthetic brain MR image to show the intermediate illustrations and the estimated distribution of the proposed algorithm. The next group of experiments is carried out in clinical 3T-weighted brain MR images which contain quite serious intensity inhomogeneity and noise. Then we quantitatively compare our algorithm to state-of-the-art segmentation approaches by using Dice coefficient (DC) on benchmark images obtained from IBSR and BrainWeb with different level of noise and intensity inhomogeneity. The comparison results on various brain MR images demonstrate the superior performances of the proposed algorithm in dealing with the noise and intensity inhomogeneity. In this paper, the RGAGMM

  3. Intraoperative indocyanine green fluorescent angiography-assisted modified superior gluteal artery perforator flap for reconstruction of sacral pressure sores.

    Science.gov (United States)

    Chang, Chun-Kai; Wu, Chien-Ju; Chen, Chun-Yu; Wang, Chi-Yu; Chu, Tzi-Shiang; Hsu, Kuo-Feng; Chiu, Han-Ting; Liu, Hung-Hui; Chou, Chang-Yi; Wang, Chih-Hsin; Lin, Chin-Ta; Dai, Niann-Tzyy; Tzeng, Yuan-Sheng

    2017-12-01

    Pressure sores are often observed in patients who are bedridden. They can be a severe problem not only for patients and their caregivers but also for plastic surgeons. Here, we describe a new method of superior gluteal artery perforator flap harvesting and anchoring with the assistance of intraoperative indocyanine green fluorescent angiography. In this report, we describe the procedure and outcomes for 19 patients with grades III and IV sacral pressure sores who underwent the operation between September 2015 and November 2016. All flaps survived, and two experienced wound-edge partial dehiscence. With the assistance of this imaging device, we were able to acquire a reliable superior gluteal artery perforator flap and perform modified operations with it that are safe, easy to learn and associated with fewer complications than are traditional. © 2017 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  4. Novel anammox bacteria and nitrogen loss from Lake Superior

    DEFF Research Database (Denmark)

    Crowe, Sean A.; Treusch, Alexander H.; Forth, Michael

    2017-01-01

    and diversity of anammox bacteria in the world's largest freshwater lake - Lake Superior. We found that anammox performed by previously undiscovered bacteria is an important contributor to sediment N2 production. We observed striking differences in the anammox bacterial populations found at different locations...... within Lake Superior and those described from other locations. Our data thus reveal that novel anammox bacteria underpin N-loss from Lake Superior, and if more broadly distributed across inland waters would play an important role in continental N-cycling and mitigation of fixed nitrogen transfer from...

  5. Mechanics of bioinspired imaging systems

    Directory of Open Access Journals (Sweden)

    Zhengwei Li

    2016-01-01

    Full Text Available Imaging systems in nature have attracted a lot of research interest due to their superior optical and imaging characteristics. Recent advancements in materials science, mechanics, and stretchable electronics have led to successful development of bioinspired cameras that resemble the structures and functions of biological light-sensing organs. In this review, we discuss some recent progresses in mechanics of bioinspired imaging systems, including tunable hemispherical eyeball camera and artificial compound eye camera. The mechanics models and results reviewed in this article can provide efficient tools for design and optimization of such systems, as well as other related optoelectronic systems that combine rigid elements with soft substrates.

  6. The picture superiority effect in associative recognition.

    Science.gov (United States)

    Hockley, William E

    2008-10-01

    The picture superiority effect has been well documented in tests of item recognition and recall. The present study shows that the picture superiority effect extends to associative recognition. In three experiments, students studied lists consisting of random pairs of concrete words and pairs of line drawings; then they discriminated between intact (old) and rearranged (new) pairs of words and pictures at test. The discrimination advantage for pictures over words was seen in a greater hit rate for intact picture pairs, but there was no difference in the false alarm rates for the two types of stimuli. That is, there was no mirror effect. The same pattern of results was found when the test pairs consisted of the verbal labels of the pictures shown at study (Experiment 4), indicating that the hit rate advantage for picture pairs represents an encoding benefit. The results have implications for theories of the picture superiority effect and models of associative recognition.

  7. Skull fracture with effacement of the superior sagittal sinus following drone impact: a case report.

    Science.gov (United States)

    Chung, Lawrance K; Cheung, Yuri; Lagman, Carlito; Au Yong, Nicholas; McBride, Duncan Q; Yang, Isaac

    2017-09-01

    The popularity of unmanned aerial vehicles, or drones, raises safety concerns as they become increasingly common for commercial, personal, and recreational use. Collisions between drones and people may result in serious injuries. A 13-year-old male presented with a comminuted depressed skull fracture causing effacement of the superior sagittal sinus secondary to a racing drone impact. The patient experienced a brief loss of consciousness and reported lower extremity numbness and weakness after the accident. Imaging studies revealed bone fragments crossing the superior sagittal sinus with a short, focal segment of blood flow interruption. Neurosurgical intervention was deferred given the patient's improving neurological deficits, and the patient was treated conservatively. He was discharged home in stable condition. Drones may represent a hazard when operated inappropriately due to their capacity to fly at high speeds and altitudes. Impacts from drones can carry enough force to cause skull fractures and significant head injuries. The rising popularity of drones likely translates to an increased incidence of drone-related injuries. Thus, clinicians should be aware of this growing trend.

  8. MnO-carbon hybrid nanofiber composites as superior anode materials for lithium-ion batteries

    International Nuclear Information System (INIS)

    Wang, Jian-Gan; Yang, Ying; Huang, Zheng-Hong; Kang, Feiyu

    2015-01-01

    MnO-carbon hybrid nanofiber composites are fabricated by electrospinning polyimide/manganese acetylacetonate precursor and a subsequent carbonization process. The composition, phase structure and morphology of the composites are characterized by scanning and transmission electron microscopy, X-ray diffraction and thermogravimetric analysis. The results indicate that the composites exhibit good nanofibrous morphology with MnO nanoparticles uniformly encapsulated by carbon nanofibers. The hybrid nanofiber composites are used directly as freestanding anodes for lithium-ion batteries to evaluate their electrochemical properties. It is found that the optimized MnO-carbon nanofiber composite can deliver a high reversible capacity of 663 mAh g −1 , along with excellent cycling stability and good rate capability. The superior performance enables the composites to be promising candidates as an anode alternative for high-performance lithium-ion batteries

  9. Angularly-selective transmission imaging in a scanning electron microscope.

    Science.gov (United States)

    Holm, Jason; Keller, Robert R

    2016-08-01

    This work presents recent advances in transmission scanning electron microscopy (t-SEM) imaging control capabilities. A modular aperture system and a cantilever-style sample holder that enable comprehensive angular selectivity of forward-scattered electrons are described. When combined with a commercially available solid-state transmission detector having only basic bright-field and dark-field imaging capabilities, the advances described here enable numerous transmission imaging modes. Several examples are provided that demonstrate how contrast arising from diffraction to mass-thickness can be obtained. Unanticipated image contrast at some imaging conditions is also observed and addressed. Published by Elsevier B.V.

  10. Pictures, images, and recollective experience.

    Science.gov (United States)

    Dewhurst, S A; Conway, M A

    1994-09-01

    Five experiments investigated the influence of picture processing on recollective experience in recognition memory. Subjects studied items that differed in visual or imaginal detail, such as pictures versus words and high-imageability versus low-imageability words, and performed orienting tasks that directed processing either toward a stimulus as a word or toward a stimulus as a picture or image. Standard effects of imageability (e.g., the picture superiority effect and memory advantages following imagery) were obtained only in recognition judgments that featured recollective experience and were eliminated or reversed when recognition was not accompanied by recollective experience. It is proposed that conscious recollective experience in recognition memory is cued by attributes of retrieved memories such as sensory-perceptual attributes and records of cognitive operations performed at encoding.

  11. Magnetic resonance imaging in the diagnosis of pancreatic diseases

    International Nuclear Information System (INIS)

    Yamaguchi, Taketo; Ebara, Masaaki; Saisho, Hiromitsu

    1987-01-01

    Fifty patients with various pancreatic diseases and 22 without pancreatic disease were studied by a magnetic resonance imaging (MRI) to compare its diagnostic capability with that by an X-ray CT scan. To differentiate pancreas clearly from the bowel, an iron solution was orally administered as contrast medium, resulting in a usefullness, especially to differentiate the head of the pancreas from the bowel. The head of the pancreas could be identified in 89 % after iron solution but only in 62 % without it. MRI was inferior to CT in terms of visualization of the pancreatic duct and pancreatic stones, but was superior in a visualization of vessels around the pancreas. MRI was considered to be useful for a detection of carcinoma infiltrating to vessels. Pancreatic carcinoma was differentiated from chronic pancreatitis in terms of a local enlargement and disappearance of fat around the pancreas shown on MRI findings. The present results also showed statistically significant differences in T 1 relaxation times among normal pancreas, chronic pancreatitis and pancreatic carcinoma, suggesting a useful marker in the differential diagnosis of pancreatic diseases. (author)

  12. Automated cart with VIS/NIR hyperspectral reflectance and fluorescence imaging capabilities

    Science.gov (United States)

    A system to take high-resolution VIS/NIR hyperspectral reflectance and fluorescence images in outdoor fields using ambient lighting or a pulsed laser (355 nm), respectively, for illumination was designed, built, and tested. Components of the system include a semi-autonomous cart, a gated-intensified...

  13. Dissociable contributions of MRI volume reductions of superior temporal and fusiform gyri to symptoms and neuropsychology in schizophrenia ☆

    OpenAIRE

    Nestor, Paul G.; Onitsuka, Toshiaki; Gurrera, Ronald J.; Niznikiewicz, Margaret; Frumin, Melissa; Shenton, Martha E.; McCarley, Robert W.

    2007-01-01

    We sought to identify the functional correlates of reduced magnetic resonance imaging (MRI) volumes of the superior temporal gyrus (STG) and the fusiform gyrus (FG) in patients with chronic schizophrenia. MRI volumes, positive/negative symptoms, and neuropsychological tests of facial memory and executive functioning were examined within the same subjects. The results indicated two distinct, dissociable brain structure-function relationships: (1) reduced left STG volume-positive symptoms-execu...

  14. REMOTELY SENSEDC IMAGE COMPRESSION BASED ON WAVELET TRANSFORM

    Directory of Open Access Journals (Sweden)

    Heung K. Lee

    1996-06-01

    Full Text Available In this paper, we present an image compression algorithm that is capable of significantly reducing the vast mount of information contained in multispectral images. The developed algorithm exploits the spectral and spatial correlations found in multispectral images. The scheme encodes the difference between images after contrast/brightness equalization to remove the spectral redundancy, and utilizes a two-dimensional wavelet trans-form to remove the spatial redundancy. The transformed images are than encoded by hilbert-curve scanning and run-length-encoding, followed by huffman coding. We also present the performance of the proposed algorithm with KITSAT-1 image as well as the LANDSAT MultiSpectral Scanner data. The loss of information is evaluated by peak signal to noise ratio (PSNR and classification capability.

  15. Segmentation of dermatoscopic images by frequency domain filtering and k-means clustering algorithms.

    Science.gov (United States)

    Rajab, Maher I

    2011-11-01

    Since the introduction of epiluminescence microscopy (ELM), image analysis tools have been extended to the field of dermatology, in an attempt to algorithmically reproduce clinical evaluation. Accurate image segmentation of skin lesions is one of the key steps for useful, early and non-invasive diagnosis of coetaneous melanomas. This paper proposes two image segmentation algorithms based on frequency domain processing and k-means clustering/fuzzy k-means clustering. The two methods are capable of segmenting and extracting the true border that reveals the global structure irregularity (indentations and protrusions), which may suggest excessive cell growth or regression of a melanoma. As a pre-processing step, Fourier low-pass filtering is applied to reduce the surrounding noise in a skin lesion image. A quantitative comparison of the techniques is enabled by the use of synthetic skin lesion images that model lesions covered with hair to which Gaussian noise is added. The proposed techniques are also compared with an established optimal-based thresholding skin-segmentation method. It is demonstrated that for lesions with a range of different border irregularity properties, the k-means clustering and fuzzy k-means clustering segmentation methods provide the best performance over a range of signal to noise ratios. The proposed segmentation techniques are also demonstrated to have similar performance when tested on real skin lesions representing high-resolution ELM images. This study suggests that the segmentation results obtained using a combination of low-pass frequency filtering and k-means or fuzzy k-means clustering are superior to the result that would be obtained by using k-means or fuzzy k-means clustering segmentation methods alone. © 2011 John Wiley & Sons A/S.

  16. Bi-level image compression with tree coding

    DEFF Research Database (Denmark)

    Martins, Bo; Forchhammer, Søren

    1996-01-01

    Presently, tree coders are the best bi-level image coders. The current ISO standard, JBIG, is a good example. By organising code length calculations properly a vast number of possible models (trees) can be investigated within reasonable time prior to generating code. Three general-purpose coders...... are constructed by this principle. A multi-pass free tree coding scheme produces superior compression results for all test images. A multi-pass fast free template coding scheme produces much better results than JBIG for difficult images, such as halftonings. Rissanen's algorithm `Context' is presented in a new...

  17. Color image Segmentation using automatic thresholding techniques

    International Nuclear Information System (INIS)

    Harrabi, R.; Ben Braiek, E.

    2011-01-01

    In this paper, entropy and between-class variance based thresholding methods for color images segmentation are studied. The maximization of the between-class variance (MVI) and the entropy (ME) have been used as a criterion functions to determine an optimal threshold to segment images into nearly homogenous regions. Segmentation results from the two methods are validated and the segmentation sensitivity for the test data available is evaluated, and a comparative study between these methods in different color spaces is presented. The experimental results demonstrate the superiority of the MVI method for color image segmentation.

  18. Implementation of the Land, Atmosphere Near Real-Time Capability for EOS (LANCE)

    Science.gov (United States)

    Michael, Karen; Murphy, Kevin; Lowe, Dawn; Masuoka, Edward; Vollmer, Bruce; Tilmes, Curt; Teague, Michael; Ye, Gang; Maiden, Martha; Goodman, H. Michael; hide

    2010-01-01

    The past decade has seen a rapid increase in availability and usage of near real-time data from satellite sensors. Applications have demonstrated the utility of timely data in a number of areas ranging from numerical weather prediction and forecasting, to monitoring of natural hazards, disaster relief, agriculture and homeland security. As applications mature, the need to transition from prototypes to operational capabilities presents an opportunity to improve current near real-time systems and inform future capabilities. This paper presents NASA s effort to implement a near real-time capability for land and atmosphere data acquired by the Moderate Resolution Imaging Spectroradiometer (MODIS), Atmospheric Infrared Sounder (AIRS), Advanced Microwave Scanning Radiometer - Earth Observing System (AMSR-E), Microwave Limb Sounder (MLS) and Ozone Monitoring Instrument (OMI) instruments on the Terra, Aqua, and Aura satellites. Index Terms- Real time systems, Satellite applications

  19. Long ranging swept-source optical coherence tomography-based angiography outperforms its spectral-domain counterpart in imaging human skin microcirculations

    Science.gov (United States)

    Xu, Jingjiang; Song, Shaozhen; Men, Shaojie; Wang, Ruikang K.

    2017-11-01

    There is an increasing demand for imaging tools in clinical dermatology that can perform in vivo wide-field morphological and functional examination from surface to deep tissue regions at various skin sites of the human body. The conventional spectral-domain optical coherence tomography-based angiography (SD-OCTA) system is difficult to meet these requirements due to its fundamental limitations of the sensitivity roll-off, imaging range as well as imaging speed. To mitigate these issues, we demonstrate a swept-source OCTA (SS-OCTA) system by employing a swept source based on a vertical cavity surface-emitting laser. A series of comparisons between SS-OCTA and SD-OCTA are conducted. Benefiting from the high system sensitivity, long imaging range, and superior roll-off performance, the SS-OCTA system is demonstrated with better performance in imaging human skin than the SD-OCTA system. We show that the SS-OCTA permits remarkable deep visualization of both structure and vasculature (up to ˜2 mm penetration) with wide field of view capability (up to 18×18 mm2), enabling a more comprehensive assessment of the morphological features as well as functional blood vessel networks from the superficial epidermal to deep dermal layers. It is expected that the advantages of the SS-OCTA system will provide a ground for clinical translation, benefiting the existing dermatological practice.

  20. [Reconstruction of maxillary sinus superior wall fractures with calcium phosphate cement/recombinant human bonemorphogenetic protein 7 compound implanted material in rabbit].

    Science.gov (United States)

    Zhang, Qunhui; Yu, Feng; Zhang, Haoliang; Gong, Huicheng; Lin, Ying

    2015-11-01

    To evaluate the osteogenetic character and repairing maxillary sinus superior wall fractures capability of calcium phosphate cement (CPC) before and after combined with recombinant human bone morphogenetie protein-7(rhBMP-7). A 10 mmX5 mm bone defect in the maxillary sinus superior wall was induced by surgery in all 24 New Zealand white rabbits. These 24 rabbits were randomly divided into two groups. The defects were repaired with CPC group (n = 12) and CPC/rhBMP-7 group (n = 12). The osteogenesis of bone defect was monitored by gro'ss observation, histological examination, observation under scanning electron microscope and measurement of ALP activity at 6 and 12 weeks after the implantation. In group CPC,new bone was found to form slowly and little by little. In group CPC/rhBMP-7, however, new bone was observed to form early and massively. The ALP activity in group CPC showed significant statistical difference with that of group CPC/rhBMP-7 (P < 0.05). The CPC/rhBMP-7 composite has osteoconductibility and osteoinductibility, comparing the use of CPC/rhBMP-7 with CPC for the repair of orbital fracture, the former show obvious advantage repairing ability in maxillary sinus superior wall defect.

  1. Superior intellectual ability in schizophrenia: neuropsychological characteristics.

    Science.gov (United States)

    MacCabe, James H; Brébion, Gildas; Reichenberg, Abraham; Ganguly, Taposhri; McKenna, Peter J; Murray, Robin M; David, Anthony S

    2012-03-01

    It has been suggested that neurocognitive impairment is a core deficit in schizophrenia. However, it appears that some patients with schizophrenia have intelligence quotients (IQs) in the superior range. In this study, we sought out schizophrenia patients with an estimated premorbid Intelligence Quotient (IQ) of at least 115 and studied their neuropsychological profile. Thirty-four patients meeting diagnostic criteria for schizophrenia or schizoaffective disorder, as defined by the Diagnostic and Statistical Manual of Mental Disorders (4th ed.; DSM-IV), with mean estimated premorbid IQ of 120, were recruited and divided into two subgroups, according to whether or not their IQ had declined by at least 10 points from their premorbid estimate. Their performance on an extensive neuropsychological battery was compared with that of 19 IQ-matched healthy controls and a group of 16 "typical" schizophrenia patients with estimated premorbid IQ Schizophrenia patients whose estimated premorbid and current IQ both lay in the superior range were statistically indistinguishable from IQ-matched healthy controls on all neurocognitive tests. However, their profile of relative performance in subtests was similar to that of typical schizophrenia patients. Patients with superior premorbid IQ and evidence of intellectual deterioration had intermediate scores. Our results confirm the existence of patients meeting DSM-IV diagnostic criteria for schizophrenia who have markedly superior premorbid intellectual level and appear to be free of gross neuropsychological deficits. We discuss the implications of these findings for the primacy of cognitive deficits in schizophrenia.

  2. Imaging of postpartum complications

    International Nuclear Information System (INIS)

    Rooholamini, S.A.; Au, A.H.; Hansen, G.C.; Kioumehr, F.; Yaghmai, I.

    1991-01-01

    The purpose of this paper is to evaluate the efficacy of various imaging modalities in the detection of postpartum complications. Nineteen cases of postpartum complications, studied radiologically, form the basis of this exhibit. Plain abdominal radiography, US, CT, and MR imaging were performed alone or in combination. The abnormalities detected included uterine rupture, intramural uterine hematoma, hematomas of the broad ligaments and the abdominal rectus muscles, ovarian vein thrombosis, HELLP syndrome, pyometrium, retained placenta and blood clots, periappendiceal abscess, superior sagittal sinus thrombosis, and cerebral edema. Representative cases will be illustrated; and the effective value of each technique will be stressed

  3. A slice of π: An exploratory neuroimaging study of digit encoding and retrieval in a superior memorist

    OpenAIRE

    Raz, Amir; Packard, Mark G.; Alexander, Gerianne M.; Buhle, Jason T.; Zhu, Hongtu; Yu, Shan; Peterson, Bradley S.

    2009-01-01

    Subject PI demonstrated superior memory using a variant of a Method of Loci (MOL) technique to recite the first digits of the mathematical constant π to more than 216 decimal places. We report preliminary behavioral, functional magnetic resonance imaging (fMRI), and brain volumetric data from PI. fMRI data collected while PI recited the first 540 digits of π (i.e., during retrieval) revealed increased activity in medial frontal gyrus and dorsolateral prefrontal cortex. Encoding of a novel str...

  4. Right superior vena cava draining into the left atrium

    Energy Technology Data Exchange (ETDEWEB)

    Calcagni, Giulio; Sidi, Daniel; Bonnet, Damien [University Rene Descartes-Paris 5, Department of Paediatric Cardiology, Hopital Necker-Enfants Malades, Paris (France); Batisse, Alain [Institut de Puericulture et de Perinatalogie, Paris (France); Vouhe, Pascal [University Rene Descartes-Paris 5, Department of Paediatric Cardiac Surgery, Hopital Necker-Enfants Malades, Paris (France); Ou, Phalla [University Rene Descartes-Paris 5, Department of Paediatric Cardiology, Hopital Necker-Enfants Malades, Paris (France); University Rene Descartes-Paris 5, Department of Pediatric Radiology, Hopital Necker-Enfants Malades, Paris (France)

    2008-08-15

    The right superior vena cava draining into the left atrium is a rare malformation causing cyanosis and clubbing in patients in whom no other signs of congenital heart defect are present. Diagnosis may be difficult as cyanosis may be mild and the anomaly is not always easily detectable by echocardiography. For this reason we report a 13-month-old male in whom we confirmed the clinical and echocardiographic suspicion of anomalous drainage of the right superior vena cava using multidetector CT. This allowed successful surgical reconnection of the right superior vena cava to the right atrium. (orig.)

  5. Right superior vena cava draining into the left atrium

    International Nuclear Information System (INIS)

    Calcagni, Giulio; Sidi, Daniel; Bonnet, Damien; Batisse, Alain; Vouhe, Pascal; Ou, Phalla

    2008-01-01

    The right superior vena cava draining into the left atrium is a rare malformation causing cyanosis and clubbing in patients in whom no other signs of congenital heart defect are present. Diagnosis may be difficult as cyanosis may be mild and the anomaly is not always easily detectable by echocardiography. For this reason we report a 13-month-old male in whom we confirmed the clinical and echocardiographic suspicion of anomalous drainage of the right superior vena cava using multidetector CT. This allowed successful surgical reconnection of the right superior vena cava to the right atrium. (orig.)

  6. La educación superior como eje del desarrollo

    Directory of Open Access Journals (Sweden)

    Benjamín Afanador Vargas

    2003-11-01

    Full Text Available Este documento analiza cómo ha sido la interacción entre la política educativa y las estrategiasde desarrollo en Colombia, a lo largo del siglo XX. Se presenta una revisión del estadoactual de la educación en Colombia, tanto a nivel de educación básica y media, como de laeducación superior. Para ello se toman tres criterios básicos que son la cobertura, la calidady la equidad en el acceso a la educación. Para el caso de la educación superior, se comparala oferta de cupos con la demanda existente, se clasifican los distintos segmentos en que sedivide la educación superior y se hace una breve reseña sobre el recurso humano con que secuenta en la educación superior colombiana. Así mismo, se expone una conceptualización delos retos que enfrenta la educación superior, sobretodo para lograr una cohesión de la sociedad,evitando que algunos de sus integrantes sean excluidos y permitiendo que todos losestamentos de la sociedad puedan compartir los mismos ideales y los consideren asequibles.Finalmente, se presentan unas conclusiones que se derivan del estudio y se proponen algunasrecomendaciones de política .

  7. Forced expression of Sox2 or Nanog in human bone marrow derived mesenchymal stem cells maintains their expansion and differentiation capabilities

    International Nuclear Information System (INIS)

    Go, Masahiro J.; Takenaka, Chiemi; Ohgushi, Hajime

    2008-01-01

    Mesenchymal stem cells (MSCs) derived from human bone marrow have capability to differentiate into cells of mesenchymal lineage. The cells have already been applied in various clinical situations because of their expansion and differentiation capabilities. The cells lose their capabilities after several passages, however. With the aim of conferring higher capability on human bone marrow MSCs, we introduced the Sox2 or Nanog gene into the cells. Sox2 and Nanog are not only essential for pluripotency and self-renewal of embryonic stem cells, but also expressed in somatic stem cells that have superior expansion and differentiation potentials. We found that Sox2-expressing MSCs showed consistent proliferation and osteogenic capability in culture media containing basic fibroblast growth factor (bFGF) compared to control cells. Significantly, in the presence of bFGF in culture media, most of the Sox2-expressing cells were small, whereas the control cells were elongated in shape. We also found that Nanog-expressing cells even in the absence of bFGF had much higher capabilities for expansion and osteogenesis than control cells. These results demonstrate not only an effective way to maintain proliferation and differentiation potentials of MSCs but also an important implication about the function of bFGF for self-renewal of stem cells including MSCs

  8. Helical CT finding of carotid-cavernous fistula: a sign of early enhancing superior ophthalmic vein

    International Nuclear Information System (INIS)

    Kim, Jae Hyung; Na, Dong Gyu; Byun, Hong Sik; Ryoo, Jae Wook

    2000-01-01

    The purpose of this study was to determine the diagnostic value of a sign of early enhancing superior ophthalmic vein (SOV), as seen on helical CT images in patients with carotid-cavernous fistula (CCF). This study involved 16 patients with CCF and 28 control patients. Axial CT images with scanning delays of 30 seconds following bolus injection of contrast material (90 mL, 3 mL/sec) were obtained, and this procedure was followed by coronal CT imaging. To determine the presence or absence of early enhancement or, dilatation of the SOV, bulging of the cavernous sinus, and enlargement of extraocular muscle, CT images were analysed by three observers in a blinded, random manner. Early enhancement of SOV was determined to be present where enhancement of the SOV was similar to or stronger than that of the ipsilateral posterior cerebral artery. A sign of early enhancing SOV was seen in 14 of the 16 patients with CCF but in no control patients (88% sensitivity and 100% specificity). The respective sensitivity and specificity of other CT features were 71% and 100% (dilatation of the SOV, as seen on axial images), 60% and 83% (dilatation of the SOV, as seen on coronal images), 71% and 89% (dilatation of the cavernous sinus), and 65% and 98% (enlargement of extraocular muscle). A sign of early enhancing SOV is a characteristic and specific CT finding of CCF, and is useful for the diagnosis of CCF. (author)

  9. Magnetic resonance imaging of hypothalamic hamartoma

    Energy Technology Data Exchange (ETDEWEB)

    Kanazawa, Junichi; Uozumi, Tohru; Sakoda, Katsuaki; Yamanaka, Masami; Kihara, Mikio; Nishi, Yoshikazu; Kagawa, Yoshihiro; Kajima, Toshio.

    1988-05-01

    Magnetic resonance (MR) findings of two patients with a hypothalamic hamartoma are discussed. The two girls showed clinical symptoms and endocrinological signs of precocious puberty. MR imaging was of diagnostic value superior to that of CT in the demonstration of the characteristic location of this tumor and relationships to the neighboring structures because of its multi-dimensional utility. Although it has been reported that CT showed this lesion as isodense to the grey matter with and without injection of contrast medium, MR imaging depicted the lesion as a high signal intensity area on T2-weighted images in both patients. MR imaging is a useful method for the evaluation of the hypothalamic hamartoma.

  10. Capability-based computer systems

    CERN Document Server

    Levy, Henry M

    2014-01-01

    Capability-Based Computer Systems focuses on computer programs and their capabilities. The text first elaborates capability- and object-based system concepts, including capability-based systems, object-based approach, and summary. The book then describes early descriptor architectures and explains the Burroughs B5000, Rice University Computer, and Basic Language Machine. The text also focuses on early capability architectures. Dennis and Van Horn's Supervisor; CAL-TSS System; MIT PDP-1 Timesharing System; and Chicago Magic Number Machine are discussed. The book then describes Plessey System 25

  11. A Versatile Image Processor For Digital Diagnostic Imaging And Its Application In Computed Radiography

    Science.gov (United States)

    Blume, H.; Alexandru, R.; Applegate, R.; Giordano, T.; Kamiya, K.; Kresina, R.

    1986-06-01

    In a digital diagnostic imaging department, the majority of operations for handling and processing of images can be grouped into a small set of basic operations, such as image data buffering and storage, image processing and analysis, image display, image data transmission and image data compression. These operations occur in almost all nodes of the diagnostic imaging communications network of the department. An image processor architecture was developed in which each of these functions has been mapped into hardware and software modules. The modular approach has advantages in terms of economics, service, expandability and upgradeability. The architectural design is based on the principles of hierarchical functionality, distributed and parallel processing and aims at real time response. Parallel processing and real time response is facilitated in part by a dual bus system: a VME control bus and a high speed image data bus, consisting of 8 independent parallel 16-bit busses, capable of handling combined up to 144 MBytes/sec. The presented image processor is versatile enough to meet the video rate processing needs of digital subtraction angiography, the large pixel matrix processing requirements of static projection radiography, or the broad range of manipulation and display needs of a multi-modality diagnostic work station. Several hardware modules are described in detail. For illustrating the capabilities of the image processor, processed 2000 x 2000 pixel computed radiographs are shown and estimated computation times for executing the processing opera-tions are presented.

  12. Self and Superior Assessment.

    Science.gov (United States)

    1986-06-01

    model of the self-evaluation process as it differs from the evaluation process used by superiors. Symbolic Interactionism One view of self assessment is...supplied by the symbolic interactionists (Cooley, 1902; Head, 1934), who state that self perceptions are generated largely from individuals...disagreements remained even immediately after an appraisal interview in which a great deal of feedback was given. Research on the symbolic interactionist

  13. WE-DE-207A-04: Advances in Radiological Neuro-Endovascular Interventional Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Rudin, S. [University at Buffalo (SUNY) School of Medicine (United States)

    2016-06-15

    audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens

  14. WE-DE-207A-04: Advances in Radiological Neuro-Endovascular Interventional Imaging

    International Nuclear Information System (INIS)

    Rudin, S.

    2016-01-01

    audience. Learning Objectives: To understand the clinical need of one-stop-shop stroke imaging workflow To understand to technical challenges in cone beam CT perfusion To understand the potential technical solutions to enable one-stop-shop imaging workflow Recent advances in devices used in neuro--interventions Mattew Gounis - Over the past two decades, there has been explosive development of medical devices that have revolutionized the endovascular treatment of cerebrovascular diseases. There is now Level 1, Class A evidence that intra-arterial, mechanical thrombectomy in acute ischemic stroke is superior to medical management; and similarly that minimally invasive, endovascular repair of ruptured brain aneurysms is superior to surgical treatment. Stent-retrievers are now standard of care for emergent large vessel occlusions causing a stroke, with a number of patients need to treat for good clinical outcomes as low as 4. Recent technologies such as flow diverters and disrupters, intracranial self-expanding stents, flexible large bore catheters that can reach vessels beyond the circle of Willis, stent-retrievers, and super-compliant balloons are the result of successful miniaturization of design features and novel manufacturing technologies capable of building these devices. This is a rapidly evolving field, and the device technology enabling such advancements will be reviewed. Importantly, image-guidance technology has not kept pace in neurointervention and the ability to adequately characterize these devices in vivo remains a significant opportunity. Learning Objectives: A survey of devices used in neurointerventions, their materials and essential design characteristics Funding support received from NIH and DOD; Funding support received from GE Healthcare; Funding support received from Siemens AX; Patent royalties received from GE Healthcare; G. Chen, Funding received from NIH; funding received from DOD; funding received from GE Healthcare; funding received from Siemens

  15. 14 CFR 385.7 - Exercise of authority by superiors.

    Science.gov (United States)

    2010-01-01

    ... PROCEEDINGS) ORGANIZATION STAFF ASSIGNMENTS AND REVIEW OF ACTION UNDER ASSIGNMENTS General Provisions § 385.7 Exercise of authority by superiors. Any assignment of authority to a staff member other than the Chief... be made, severally, to each such staff member's respective superiors. In accordance with the...

  16. Small-scale anomaly detection in panoramic imaging using neural models of low-level vision

    Science.gov (United States)

    Casey, Matthew C.; Hickman, Duncan L.; Pavlou, Athanasios; Sadler, James R. E.

    2011-06-01

    Our understanding of sensory processing in animals has reached the stage where we can exploit neurobiological principles in commercial systems. In human vision, one brain structure that offers insight into how we might detect anomalies in real-time imaging is the superior colliculus (SC). The SC is a small structure that rapidly orients our eyes to a movement, sound or touch that it detects, even when the stimulus may be on a small-scale; think of a camouflaged movement or the rustle of leaves. This automatic orientation allows us to prioritize the use of our eyes to raise awareness of a potential threat, such as a predator approaching stealthily. In this paper we describe the application of a neural network model of the SC to the detection of anomalies in panoramic imaging. The neural approach consists of a mosaic of topographic maps that are each trained using competitive Hebbian learning to rapidly detect image features of a pre-defined shape and scale. What makes this approach interesting is the ability of the competition between neurons to automatically filter noise, yet with the capability of generalizing the desired shape and scale. We will present the results of this technique applied to the real-time detection of obscured targets in visible-band panoramic CCTV images. Using background subtraction to highlight potential movement, the technique is able to correctly identify targets which span as little as 3 pixels wide while filtering small-scale noise.

  17. Increasing the sensitivity for stem cell monitoring in system-function based magnetic particle imaging

    International Nuclear Information System (INIS)

    Them, Kolja; Szwargulski, P; Knopp, Tobias; Salamon, J; Kaul, M G; Ittrich, H; Sequeira, S; Lange, C

    2016-01-01

    The use of superparamagnetic iron oxide nanoparticles (SPIONs) has provided new possibilities in biophysics and biomedical imaging technologies. The magnetization dynamics of SPIONs, which can be influenced by the environment, are of central interest. In this work, different biological SPION environments are used to investigate three different calibration methods for stem cell monitoring in magnetic particle imaging. It is shown that calibrating using SPIONs immobilized via agarose gel or intracellular uptake results in superior stem cell image quality compared to mobile SPIONs in saline. This superior image quality enables more sensitive localization and identification of a significantly smaller number of magnetically labeled stem cells. The results are important for cell tracking and monitoring of future SPION based therapies such as hyperthermia based cancer therapies, targeted drug delivery, or tissue regeneration approaches where it is crucial to image a sufficiently small number of SPIONs interacting with biological matter. (paper)

  18. Mobile Test Capabilities

    Data.gov (United States)

    Federal Laboratory Consortium — The Electrical Power Mobile Test capabilities are utilized to conduct electrical power quality testing on aircraft and helicopters. This capability allows that the...

  19. Facile Synthesis of Porous ZnMnO3 Spherulites with a High Lithium Storage Capability

    International Nuclear Information System (INIS)

    Liu, Xinru; Zhao, Chenhao; Zhang, He; Shen, Qiang

    2015-01-01

    Graphical abstract: Porous ZnMnO 3 spherulites show an enhanced high lithium storage capability when potentially applied as a lithium-ion battery anode for the first time. - Highlights: • Composite Zn 0.5 Mn 0.5 CO 3 microspheres are facilely co-precipitated. • Porous ZnMnO 3 spherulites can be used as a lithium-ion battery anode. • Porous ZnMnO 3 spherulites show superior electrochemical properties. • A synergistic effect of Zn-O and Mn-O components in cubic ZnMnO 3 is proposed. - Abstract: In this paper, pure-phase ZnMnO 3 porous spherulites are uniquely synthesized through the thermal decomposition of Zn-Mn binary carbonate precursors facilely co-precipitated at room temperature, possessing an average diameter of 1.2 ± 0.3 μm and acquiring porosity with a specific surface area of 24.3 m 2 g −1 . When tentatively applied as lithium-ion battery anodes for the first time, these porous spherulites deliver an initial discharge capacity of 1294 mAh g −1 at 500 mA g −1 and retain an reversible value of 879 mAh g −1 over 150 cycles. By comparison, the equimolar powder mixture of nano-sized ZnO and MnO 2 synergistically shows a higher lithium storage capability than the two unary transition metal oxides, but lower than anode material ZnMnO 3 . Aside from its nanostructured characteristics, an inner atomic synergistic effect within the cubic lattices may account for the superior electrochemical performance of well-crystallized ZnMnO 3

  20. Anatase-TiO{sub 2}/CNTs nanocomposite as a superior high-rate anode material for lithium-ion batteries

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jinlong [College of Chemistry and Chemical Engineering, Central South University, Changsha 410083 (China); State Key Laboratory of Powder Metallurgy, Central South University, Changsha 410083 (China); Feng, Haibo; Jiang, Jianbo [College of Chemistry and Chemical Engineering, Central South University, Changsha 410083 (China); Qian, Dong, E-mail: qiandong6@vip.sina.com [College of Chemistry and Chemical Engineering, Central South University, Changsha 410083 (China); State Key Laboratory of Powder Metallurgy, Central South University, Changsha 410083 (China); Li, Junhua; Peng, Sanjun [College of Chemistry and Chemical Engineering, Central South University, Changsha 410083 (China); Liu, Youcai, E-mail: liuyoucai@126.com [College of Chemistry and Chemical Engineering, Central South University, Changsha 410083 (China)

    2014-08-01

    Highlights: • Anatase-TiO{sub 2}/CNTs nanocomposite was prepared by a facile and scalable hydrolysis route. • The composite exhibits super-high rate capability and excellent cycling stability for LIBs. • The nanocomposite shows great potential as a superior anode material for LIBs. - Abstract: Anatase-TiO{sub 2}/carbon nanotubes (CNTs) with robust nanostructure is fabricated via a facile two-step synthesis by ammonia water assisted hydrolysis and subsequent calcination. The as-synthesized nanocomposite was characterized employing X-ray powder diffraction, Fourier transform infrared spectrophotometry, Raman spectrophotometry, thermal gravimetric analysis, transmission electron microscopy, high-resolution transmission electron microscopy and selected area electronic diffraction, and its electrochemical properties as an anode material for lithium-ion batteries (LIBs) were investigated by cyclic voltammetry, galvanostatic discharge/charge test and electrochemical impendence spectroscopy. The results show that the pure anatase TiO{sub 2} nanoparticles with diameters of about 10 nm are uniformly distributed on/among the CNTs conducting network. The as-synthesized nanocomposite exhibits remarkably improved performances in LIBs, especially super-high rate capability and excellent cycling stability. Specifically, a reversible capacity as high as 92 mA h g{sup −1} is achieved even at a current density of 10 A g{sup −1} (60 C). After 100 cycles at 0.1 A g{sup −1}, it shows good capacity retention of 185 mA h g{sup −1} with an outstanding coulombic efficiency up to 99%. Such superior Li{sup +} storage properties demonstrate the reinforced synergistic effects between the nano-sized TiO{sub 2} and the interweaved CNTs network, endowing the nanocomposite with great application potential in high-power LIBs.

  1. Active gated imaging for automotive safety applications

    Science.gov (United States)

    Grauer, Yoav; Sonn, Ezri

    2015-03-01

    The paper presents the Active Gated Imaging System (AGIS), in relation to the automotive field. AGIS is based on a fast gated-camera equipped with a unique Gated-CMOS sensor, and a pulsed Illuminator, synchronized in the time domain to record images of a certain range of interest which are then processed by computer vision real-time algorithms. In recent years we have learned the system parameters which are most beneficial to night-time driving in terms of; field of view, illumination profile, resolution and processing power. AGIS provides also day-time imaging with additional capabilities, which enhances computer vision safety applications. AGIS provides an excellent candidate for camera-based Advanced Driver Assistance Systems (ADAS) and the path for autonomous driving, in the future, based on its outstanding low/high light-level, harsh weather conditions capabilities and 3D potential growth capabilities.

  2. Fast susceptibility-weighted imaging with three-dimensional short-axis propeller (SAP)-echo-planar imaging.

    Science.gov (United States)

    Holdsworth, Samantha J; Yeom, Kristen W; Moseley, Michael E; Skare, S

    2015-05-01

    Susceptibility-weighted imaging (SWI) in neuroimaging can be challenging due to long scan times of three-dimensional (3D) gradient recalled echo (GRE), while faster techniques such as 3D interleaved echo-planar imaging (iEPI) are prone to motion artifacts. Here we outline and implement a 3D short-axis propeller echo-planar imaging (SAP-EPI) trajectory as a faster, motion-correctable approach for SWI. Experiments were conducted on a 3T MRI system. The 3D SAP-EPI, 3D iEPI, and 3D GRE SWI scans were acquired on two volunteers. Controlled motion experiments were conducted to test the motion-correction capability of 3D SAP-EPI. The 3D SAP-EPI SWI data were acquired on two pediatric patients as a potential alternative to 2D GRE used clinically. The 3D GRE images had a better target resolution (0.47 × 0.94 × 2 mm, scan time = 5 min), iEPI and SAP-EPI images (resolution = 0.94 × 0.94 × 2 mm) were acquired in a faster scan time (1:52 min) with twice the brain coverage. SAP-EPI showed motion-correction capability and some immunity to undersampling from rejected data. While 3D SAP-EPI suffers from some geometric distortion, its short scan time and motion-correction capability suggest that SAP-EPI may be a useful alternative to GRE and iEPI for use in SWI, particularly in uncooperative patients. © 2014 Wiley Periodicals, Inc.

  3. Building Service Provider Capabilities

    DEFF Research Database (Denmark)

    Brandl, Kristin; Jaura, Manya; Ørberg Jensen, Peter D.

    2015-01-01

    In this paper we study whether and how the interaction between clients and the service providers contributes to the development of capabilities in service provider firms. In situations where such a contribution occurs, we analyze how different types of activities in the production process...... process. We find that clients influence the development of human capital capabilities and management capabilities in reciprocally produced services. While in sequential produced services clients influence the development of organizational capital capabilities and management capital capabilities....... of the services, such as sequential or reciprocal task activities, influence the development of different types of capabilities. We study five cases of offshore-outsourced knowledge-intensive business services that are distinguished according to their reciprocal or sequential task activities in their production...

  4. New calibration technique for KCD-based megavoltage imaging

    Science.gov (United States)

    Samant, Sanjiv S.; Zheng, Wei; DiBianca, Frank A.; Zeman, Herbert D.; Laughter, Joseph S.

    1999-05-01

    In megavoltage imaging, current commercial electronic portal imaging devices (EPIDs), despite having the advantage of immediate digital imaging over film, suffer from poor image contrast and spatial resolution. The feasibility of using a kinestatic charge detector (KCD) as an EPID to provide superior image contrast and spatial resolution for portal imaging has already been demonstrated in a previous paper. The KCD system had the additional advantage of requiring an extremely low dose per acquired image, allowing for superior imaging to be reconstructed form a single linac pulse per image pixel. The KCD based images utilized a dose of two orders of magnitude less that for EPIDs and film. Compared with the current commercial EPIDs and film, the prototype KCD system exhibited promising image qualities, despite being handicapped by the use of a relatively simple image calibration technique, and the performance limits of medical linacs on the maximum linac pulse frequency and energy flux per pulse delivered. This image calibration technique fixed relative image pixel values based on a linear interpolation of extrema provided by an air-water calibration, and accounted only for channel-to-channel variations. The counterpart of this for area detectors is the standard flat fielding method. A comprehensive calibration protocol has been developed. The new technique additionally corrects for geometric distortions due to variations in the scan velocity, and timing artifacts caused by mis-synchronization between the linear accelerator and the data acquisition system (DAS). The role of variations in energy flux (2 - 3%) on imaging is demonstrated to be not significant for the images considered. The methodology is presented, and the results are discussed for simulated images. It also allows for significant improvements in the signal-to- noise ratio (SNR) by increasing the dose using multiple images without having to increase the linac pulse frequency or energy flux per pulse. The

  5. MR imaging in Peyronie's disease

    International Nuclear Information System (INIS)

    Shin, Young Yoel; Lee, Jeong Min; Lee, Sang Yong; Kim, Chong Soo; Park, Jong Kwan

    1999-01-01

    To evaluate the characteristics of magnetic resonance (MR) images in Peyronie's disease and to assess the usefulness of post-erection penile MRI. We retrospectively reviewed the MR images of seven patients in whom Peyronie's disease was clinically suspected. All seven underwent pre-and post-erectile MRI. After the acquisition of erectile MRI, three patients also underwent contrast-enhanced MRI. We compared image quality and the rate of detection of penile plaque between pre-erectile and post-erectile images. In three patients who underwent contrast-enhanced MRI, we assessed correlation between the contrast enhancement pattern, as seen on MRI, of the plaque and corpus cavernosa and clinical inflammatory signs such as painful erection. In the seven patients, all post-erectile MRI images showed localized thickening and irregularities of the tunica albuginea and the septum penis, suggesting penile plaque. On pre-erectile MRI, however, plaque was detected in five cases. In six of seven cases, plaque as seen on T2-weighted images (T2WI) showed low signal intensity similar to that of the tunica albuginea, and as seen on T1-weighted images (T1W1), a signal intensity of signal intensity similar to or similar to or slightly higher than that of the tunica albuginea. In one case, plaque showed high signal intensity on both T1WI and T2WI. On T1WI, the corpus cavernosa showed homogeneous medium-signal intensity on all pre- and post-erectile MR images. On pre-erectile T2WI, the corpus cavernosa of six patients showed heterogeneous high signal intensity, whereas on post-erectile T2WI the corpus cavernosa of all patients showed homogeneous high signal intensity. Due to the enlarged penis and homogeneous signal intensity of the corpus cavernosa, the image quality of post-erectile images was superior to that of pre-erectile images. The images of two of three patients who underwent contrast enhanced MRI showed strong enhancement of the plaque and adjacent corpus cavernosa, while in

  6. Unusual Complication of Superior Mesenteric Artery Syndrome: Spontaneous Upper Gastrointestinal Bleeding with Hypovolemic Shock

    Directory of Open Access Journals (Sweden)

    Kai-Hsiung Ko

    2009-01-01

    Full Text Available Superior mesenteric artery (SMA syndrome is an unusual form of duodenal obstruction. Complications of SMA syndrome may sometimes develop and are usually associated with marked gastric dilatation, although most complications can be corrected by supportive treatment. In this article, we report a case of severe SMA syndrome with hypovolemic shock in a 24-year-old man. Multidetector-row computed tomography with reconstructed images was performed to establish the diagnosis. Spontaneous gastrointestinal bleeding is an extremely uncommon complication of SMA syndrome, and emergent surgical intervention was unavoidable in our patient. To our knowledge, no other such case has been reported in the English-language literature.

  7. Image quality of a wet laser printer versus a paper printer for full-field digital mammograms.

    Science.gov (United States)

    Schueller, Gerd; Kaindl, Elisabeth; Matzek, Wolfgang K; Semturs, Friedrich; Schueller-Weidekamm, Claudia; Helbich, Thomas H

    2006-01-01

    The purpose of our study was to compare the image quality of a wet laser printer with that of a paper printer for full-field digital mammography (FFDM). For both a wet laser printer and a paper printer connected to an FFDM system, image quality parameters were evaluated using a standardized printer test image (luminance density, dynamic range). The detectability of standardized objects on a phantom was also evaluated. Furthermore, 640 mammograms of 80 patients with different breast tissue composition patterns were imaged with both printers. Subjective image quality parameters (brightness, contrast, and detection of details of anatomic structures-that is, skin, subcutis, musculature, glandular tissue, and fat), the detectability of breast lesions (mass, calcifications), and the diagnostic performance according to the BI-RADS classification were evaluated. Both the luminance density and the dynamic range were superior for the wet laser printer. More standardized objects were visible on the phantom imaged with the wet laser printer than with the paper printer (13/16 vs 11/16). Each subjective image quality parameter of the mammograms from the wet laser printer was rated superior to those of the paper printer. Significantly more breast lesions were detected on the wet laser printer images than on the paper printer images (masses, 13 vs 10; calcifications, 65 vs 48; p printer images, BI-RADS 4 and 5 categories were underestimated for 10 (43.5%) of 23 patients. For FFDM, images obtained from a wet laser printer show superior objective and subjective image quality compared with a paper printer. As a consequence, the paper printer should not be used for FFDM.

  8. High Resolution Imaging of the Sun with CORONAS-1

    Science.gov (United States)

    Karovska, Margarita

    1998-01-01

    We applied several image restoration and enhancement techniques, to CORONAS-I images. We carried out the characterization of the Point Spread Function (PSF) using the unique capability of the Blind Iterative Deconvolution (BID) technique, which recovers the real PSF at a given location and time of observation, when limited a priori information is available on its characteristics. We also applied image enhancement technique to extract the small scale structure imbeded in bright large scale structures on the disk and on the limb. The results demonstrate the capability of the image post-processing to substantially increase the yield from the space observations by improving the resolution and reducing noise in the images.

  9. Intraoperative cone-beam computed tomography and multi-slice computed tomography in temporal bone imaging for surgical treatment.

    Science.gov (United States)

    Erovic, Boban M; Chan, Harley H L; Daly, Michael J; Pothier, David D; Yu, Eugene; Coulson, Chris; Lai, Philip; Irish, Jonathan C

    2014-01-01

    Conventional computed tomography (CT) imaging is the standard imaging technique for temporal bone diseases, whereas cone-beam CT (CBCT) imaging is a very fast imaging tool with a significant less radiation dose compared with conventional CT. We hypothesize that a system for intraoperative cone-beam CT provides comparable image quality to diagnostic CT for identifying temporal bone anatomical landmarks in cadaveric specimens. Cross-sectional study. University tertiary care facility. Twenty cadaveric temporal bones were affixed into a head phantom and scanned with both a prototype cone-beam CT C-arm and multislice helical CT. Imaging performance was evaluated by 3 otologic surgeons and 1 head and neck radiologist. Participants were presented images in a randomized order and completed landmark identification questionnaires covering 21 structures. CBCT and multislice CT have comparable performance in identifying temporal structures. Three otologic surgeons indicated that CBCT provided statistically equivalent performance for 19 of 21 landmarks, with CBCT superior to CT for the chorda tympani and inferior for the crura of the stapes. Subgroup analysis showed that CBCT performed superiorly for temporal bone structures compared with CT. The radiologist rated CBCT and CT as statistically equivalent for 18 of 21 landmarks, with CT superior to CBCT for the crura of stapes, chorda tympani, and sigmoid sinus. CBCT provides comparable image quality to conventional CT for temporal bone anatomical sites in cadaveric specimens. Clinical applications of low-dose CBCT imaging in surgical planning, intraoperative guidance, and postoperative assessment are promising but require further investigation.

  10. Aneurysm of the superior mesenteric artery

    Energy Technology Data Exchange (ETDEWEB)

    Gebauer, A

    1984-11-01

    This is a report about 4 patients with aneurysms of the superior mesenteric artery of arteriosclerotic, mycotic and probably congenital etiology together with a review of the literature as to the etiology, diagnostic possibilities and therapy. Arteriography is the method of choice even though a diagnosis may be possible by sonography or CT in special cases. Even though an aneurysm of the superior mesenteric artery is rare, it has to be considered in the differential diagnosis of persisting abdominal problems of unknown origin. This is especially true for patients with a predisposing history such as previous or existing endocarditis, sepsis, arteriosclerosis and hypertension. Because of the possibility of rupture followed by life threating bleeding an adequate diagnostic step such as arteriography has to be considered finally.

  11. Superior mesenteric artery compression syndrome - case report

    Directory of Open Access Journals (Sweden)

    Paulo Rocha França Neto

    2011-12-01

    Full Text Available Superior mesenteric artery syndrome is an entity generally caused by the loss of the intervening mesenteric fat pad, resulting in compression of the third portion of the duodenum by the superior mesenteric artery. This article reports the case of a patient with irremovable metastatic adenocarcinoma in the sigmoid colon, that evolved with intense vomiting. Intestinal transit was carried out, which showed important gastric dilation extended until the third portion of the duodenum, compatible with superior mesenteric artery syndrome. Considering the patient's nutritional condition, the medical team opted for the conservative treatment. Four months after the surgery and conservative measures, the patient did not present vomiting after eating, maintaining previous weight. Superior mesenteric artery syndrome is uncommon and can have unspecific symptoms. Thus, high suspicion is required for the appropriate clinical adjustment. A barium examination is required to make the diagnosis. The treatment can initially require gastric decompression and hydration, besides reversal of weight loss through adequate nutrition. Surgery should be adopted only in case of clinical treatment failure.A síndrome da artéria mesentérica superior é uma entidade clínica causada geralmente pela perda do tecido adiposo mesentérico, resultando na compressão da terceira porção do duodeno pela artéria mesentérica superior. Esse artigo relata o caso clínico de uma paciente portadora de adenocarcinoma de cólon sigmoide metastático irressecável, que evoluiu com vômitos incoercíveis. Realizou-se, então, trânsito intestinal que evidenciou dilatação gástrica importante, que se prolongava até a terceira porção duodenal, quadro radiológico compatível com pinçamento da artéria mesentérica superior. Diante da condição nutricional da paciente, foi optado por iniciar medidas conservadoras (porções alimentares pequenas e mais frequentes, além de dec

  12. Air Power's First Among Equals: Why Air Superiority Still Matters

    National Research Council Canada - National Science Library

    Slawson, Andrew T

    2008-01-01

    .... History is replete with examples of successful or failed air superiority campaigns. This paper details air superiority's role in both the Battle of Britain, and the 1967 Six Day War's Operation MOKED...

  13. OMPS Near Real-time Products Available Through NASA LANCE (Land Atmosphere Near Real-time Capability for EOS)

    Science.gov (United States)

    Warnock, A.; Durbin, P. B.; Cechini, M. F.; Masuoka, E.

    2017-12-01

    Near real-time (NRT) images from the NASA Ozone Mapping and Profiler Suite (OMPS) for sulfur dioxide, total column ozone and aerosol index products are now available through NASA's online Land Atmosphere Near real-time Capability for EOS (LANCE) system. Color palettes, image dimensions and data ranges have been aligned with the corresponding OMI products, allowing for direct comparison of OMPS NRT images with OMI NRT images already available in NASA Worldview. The images are delivered to LANCE within hours of satellite observation. LANCE NRT imagery can be interactively viewed through Worldview and the Global Imagery Browse Services (GIBS).

  14. Integration of intraoperative stereovision imaging for brain shift visualization during image-guided cranial procedures

    Science.gov (United States)

    Schaewe, Timothy J.; Fan, Xiaoyao; Ji, Songbai; Roberts, David W.; Paulsen, Keith D.; Simon, David A.

    2014-03-01

    Dartmouth and Medtronic Navigation have established an academic-industrial partnership to develop, validate, and evaluate a multi-modality neurosurgical image-guidance platform for brain tumor resection surgery that is capable of updating the spatial relationships between preoperative images and the current surgical field. A stereovision system has been developed and optimized for intraoperative use through integration with a surgical microscope and an image-guided surgery system. The microscope optics and stereovision CCD sensors are localized relative to the surgical field using optical tracking and can efficiently acquire stereo image pairs from which a localized 3D profile of the exposed surface is reconstructed. This paper reports the first demonstration of intraoperative acquisition, reconstruction and visualization of 3D stereovision surface data in the context of an industry-standard image-guided surgery system. The integrated system is capable of computing and presenting a stereovision-based update of the exposed cortical surface in less than one minute. Alternative methods for visualization of high-resolution, texture-mapped stereovision surface data are also investigated with the objective of determining the technical feasibility of direct incorporation of intraoperative stereo imaging into future iterations of Medtronic's navigation platform.

  15. Basic principles of magnetic resonance imaging in cerebral ischemia and initial clinical experience

    International Nuclear Information System (INIS)

    Brant-Zawadzki, M.; Solomon, M.; Newton, T.H.; Weinstein, P.; Schmidley, J.; Norman, D.

    1985-01-01

    NMR tomography proved to be a method superior to computerized tomography (CT) in terms of sensitivity in the diagnosis of pathological changes in the brain. The article on hand gives a brief survey on the principle of the method and demonstrates the superiority of NMR tomography to CT exemplified by images taken from a number of cases. Instrumental factors influencing diagnosis of cerebral ischaemie are discussed. Clinical studies performed on more than 20 partients with suspected infarct revealed the superiority of NMR tomography to CT. (MG) [de

  16. Aging and the picture superiority effect in recall.

    Science.gov (United States)

    Winograd, E; Smith, A D; Simon, E W

    1982-01-01

    One recurrent theme in the literature on aging and memory is that the decline of memory for nonverbal information is steeper than for verbal information. This research compares verbal and visual encoding using the picture superiority effect, the finding that pictures are remembered better than words. In the first experiment, an interaction was found between age and type of material; younger subjects recalled more pictures than words while older subjects did not. However, the overall effect was small and two further experiments were conducted. In both of these experiments, the picture superiority effect was found in both age groups with no interaction. In addition, performing a semantic orienting task had no effect on recall. The finding of a picture superiority effect in older subjects indicates that nonverbal codes can be effectively used by subjects in all age groups to facilitate memory performance.

  17. Compositional-prior-guided image reconstruction algorithm for multi-modality imaging

    Science.gov (United States)

    Fang, Qianqian; Moore, Richard H.; Kopans, Daniel B.; Boas, David A.

    2010-01-01

    The development of effective multi-modality imaging methods typically requires an efficient information fusion model, particularly when combining structural images with a complementary imaging modality that provides functional information. We propose a composition-based image segmentation method for X-ray digital breast tomosynthesis (DBT) and a structural-prior-guided image reconstruction for a combined DBT and diffuse optical tomography (DOT) breast imaging system. Using the 3D DBT images from 31 clinically measured healthy breasts, we create an empirical relationship between the X-ray intensities for adipose and fibroglandular tissue. We use this relationship to then segment another 58 healthy breast DBT images from 29 subjects into compositional maps of different tissue types. For each breast, we build a weighted-graph in the compositional space and construct a regularization matrix to incorporate the structural priors into a finite-element-based DOT image reconstruction. Use of the compositional priors enables us to fuse tissue anatomy into optical images with less restriction than when using a binary segmentation. This allows us to recover the image contrast captured by DOT but not by DBT. We show that it is possible to fine-tune the strength of the structural priors by changing a single regularization parameter. By estimating the optical properties for adipose and fibroglandular tissue using the proposed algorithm, we found the results are comparable or superior to those estimated with expert-segmentations, but does not involve the time-consuming manual selection of regions-of-interest. PMID:21258460

  18. The fascicular anatomy and peak force capabilities of the sternocleidomastoid muscle.

    Science.gov (United States)

    Kennedy, Ewan; Albert, Michael; Nicholson, Helen

    2017-06-01

    The fascicular morphology of the sternocleidomastoid (SCM) is not well described in modern anatomical texts, and the biomechanical forces it exerts on individual cervical motion segments are not known. The purpose of this study is to investigate the fascicular anatomy and peak force capabilities of the SCM combining traditional dissection and modern imaging. This study is comprised of three parts: Dissection, magnetic resonance imaging (MRI) and biomechanical modelling. Dissection was performed on six embalmed cadavers: three males of age 73-74 years and three females of age 63-93 years. The fascicular arrangement and morphologic data were recorded. MRIs were performed on six young, healthy volunteers: three males of age 24-37 and three females of age 26-28. In vivo volumes of the SCM were calculated using the Cavalieri method. Modelling of the SCM was performed on five sets of computed tomography (CT) scans. This mapped the fascicular arrangement of the SCM with relation to the cervical motion segments, and used volume data from the MRIs to calculate realistic peak force capabilities. Dissection showed the SCM has four parts; sterno-mastoid, sterno-occipital, cleido-mastoid and cleido-occipital portions. Force modelling shows that peak torque capacity of the SCM is higher at lower cervical levels, and minimal at higher levels. Peak shear forces are higher in the lower cervical spine, while compression is consistent throughout. The four-part SCM is capable of producing forces that vary across the cervical motion segments. The implications of these findings are discussed with reference to models of neck muscle function and dysfunction.

  19. Advanced virtual monochromatic reconstruction of dual-energy unenhanced brain computed tomography in children: comparison of image quality against standard mono-energetic images and conventional polychromatic computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Park, Juil [Seoul National University Children' s Hospital, Department of Radiology, Seoul (Korea, Republic of); Choi, Young Hun [Seoul National University Children' s Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Cheon, Jung-Eun; Kim, Woo Sun; Kim, In-One [Seoul National University Children' s Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of); Pak, Seong Yong [Siemens Healthineers, Seoul (Korea, Republic of); Krauss, Bernhard [Siemens Healthineers, Forchheim (Germany)

    2017-11-15

    Advanced virtual monochromatic reconstruction from dual-energy brain CT has not been evaluated in children. To determine the most effective advanced virtual monochromatic imaging energy level for maximizing pediatric brain parenchymal image quality in dual-energy unenhanced brain CT and to compare this technique with conventional monochromatic reconstruction and polychromatic scanning. Using both conventional (Mono) and advanced monochromatic reconstruction (Mono+) techniques, we retrospectively reconstructed 13 virtual monochromatic imaging energy levels from 40 keV to 100 keV in 5-keV increments from dual-source, dual-energy unenhanced brain CT scans obtained in 23 children. We analyzed gray and white matter noise ratios, signal-to-noise ratios and contrast-to-noise ratio, and posterior fossa artifact. We chose the optimal mono-energetic levels and compared them with conventional CT. For Mono+maximum optima were observed at 60 keV, and minimum posterior fossa artifact at 70 keV. For Mono, optima were at 65-70 keV, with minimum posterior fossa artifact at 75 keV. Mono+ was superior to Mono and to polychromatic CT for image-quality measures. Subjective analysis rated Mono+superior to other image sets. Optimal virtual monochromatic imaging using Mono+ algorithm demonstrated better image quality for gray-white matter differentiation and reduction of the artifact in the posterior fossa. (orig.)

  20. Development Of A Dynamic Radiographic Capability Using High-Speed Video

    Science.gov (United States)

    Bryant, Lawrence E.

    1985-02-01

    High-speed video equipment can be used to optically image up to 2,000 full frames per second or 12,000 partial frames per second. X-ray image intensifiers have historically been used to image radiographic images at 30 frames per second. By combining these two types of equipment, it is possible to perform dynamic x-ray imaging of up to 2,000 full frames per second. The technique has been demonstrated using conventional, industrial x-ray sources such as 150 Kv and 300 Kv constant potential x-ray generators, 2.5 MeV Van de Graaffs, and linear accelerators. A crude form of this high-speed radiographic imaging has been shown to be possible with a cobalt 60 source. Use of a maximum aperture lens makes best use of the available light output from the image intensifier. The x-ray image intensifier input and output fluors decay rapidly enough to allow the high frame rate imaging. Data are presented on the maximum possible video frame rates versus x-ray penetration of various thicknesses of aluminum and steel. Photographs illustrate typical radiographic setups using the high speed imaging method. Video recordings show several demonstrations of this technique with the played-back x-ray images slowed down up to 100 times as compared to the actual event speed. Typical applications include boiling type action of liquids in metal containers, compressor operation with visualization of crankshaft, connecting rod and piston movement and thermal battery operation. An interesting aspect of this technique combines both the optical and x-ray capabilities to observe an object or event with both external and internal details with one camera in a visual mode and the other camera in an x-ray mode. This allows both kinds of video images to appear side by side in a synchronized presentation.

  1. Development of a dynamic radiographic capability using high-speed video

    International Nuclear Information System (INIS)

    Bryant, L.E. Jr.

    1984-01-01

    High-speed video equipment can be used to optically image up to 2000 full frames per second or 12,000 partial frames per second. X-ray image intensifiers have historically been used to image radiographic images at 30 frames per second. By combining these two types of equipment, it is possible to perform dynamic x-ray imaging of up to 2,000 full frames per second. The technique has been demonstrated using conventional, industrial x-ray sources such as 150 kV and 300 kV constant potential x-ray generators, 2.5 MeV Van de Graaffs, and linear accelerators. A crude form of this high-speed radiographic imaging has been shown to be possible with a cobalt 60 source. Use of a maximum aperture lens makes best use of the available light output from the image intensifier. The x-ray image intensifier input and output fluors decay rapidly enough to allow the high frame rate imaging. Data are presented on the maximum possible video frame rates versus x-ray penetration of various thicknesses of aluminum and steel. Photographs illustrate typical radiographic setups using the high speed imaging method. Video recordings show several demonstrations of this technique with the played-back x-ray images slowed down up to 100 times as compared to the actual event speed. Typical applications include boiling type action of liquids in metal containers, compressor operation with visualization of crankshaft, connecting rod and piston movement and thermal battery operation. An interesting aspect of this technique combines both the optical and x-ray capabilities to observe an object or event with both external and internal details with one camera in a visual mode and the other camera in an x-ray mode. This allows both kinds of video images to appear side by side in a synchronized presentation

  2. Avaliação da qualidade nos serviços educacionais das instituições de ensino superior em joinville, sc Evaluación de la calidad en los servicios educacionales de las instituciones de enseñanza superior en joinville, sc Quality evaluation of education in institutions of higher learning in joinville, sc

    Directory of Open Access Journals (Sweden)

    Emerson Wagner Mainardes

    2009-03-01

    Full Text Available Em mercados competitivos, a qualidade pode fazer a diferença. Nos últimos anos, esta tem sido a realidade do mercado de ensino superior. Para tornar eficaz a busca por qualidade, devem-se investigar os atributos que determinam a qualidade de um curso e de uma instituição de ensino superior. Este estudo procurou determinar os atributos-chave para a construção de uma imagem de qualidade nos serviços educacionais das instituições que oferecem educação superior. Testando-se 63 atributos diferentes, identificou-se que os cursos de graduação em Administração em Joinville são considerados de alta qualidade. Encontrou-se também que a imagem de qualidade de uma instituição universitária baseia-se no conjunto: administração e estruturas da instituição, valor do curso para o mercado de trabalho e corpo de professores. O fator-chave que determina a qualidade de uma instituição de ensino superior é a imagem da instituição na comunidade.En mercados competitivos, la calidad puede hacer la diferencia. En los últimos años, esta es la realidad del mercado de enseñanza superior. Para hacer eficaz la búsqueda por calidad, debemos investigar los atributos que determinan la calidad de un curso y de una institución de enseñanza superior. Este estudio ha buscado determinar los atributos clave para la construcción de una imagen de calidad en los servicios educacionales de las instituciones que ofrecen educación superior. Probándose 63 atributos diferentes, identificamos que los cursos de graduación en Administración en Joinville son considerados de alta calidad. Encontramos también que la imagen de calidad de una institución universitaria se basa en el conjunto: administración y estructuras de la institución, valor del curso para el mercado de trabajo y personal docente. El hecho clave que determina la calidad de una institución de enseñanza superior remite a la imagen de la institución para la comunidad.Quality can make a

  3. FMEF/experimental capabilities

    International Nuclear Information System (INIS)

    Burgess, C.A.; Dronen, V.R.

    1981-01-01

    The Fuels and Materials Examination Facility (FMEF), under construction at the Hanford site north of Richland, Washington, will be one of the most modern facilities offering irradiated fuels and materials examination capabilities and fuel fabrication development technologies. Scheduled for completion in 1984, the FMEF will provide examination capability for fuel assemblies, fuel pins and test pins irradiated in the FFTF. Various functions of the FMEF are described, with emphasis on experimental data-gathering capabilities in the facility's Nondestructive and Destructive examination cell complex

  4. The history of MR imaging as seen through the pages of radiology.

    Science.gov (United States)

    Edelman, Robert R

    2014-11-01

    The first reports in Radiology pertaining to magnetic resonance (MR) imaging were published in 1980, 7 years after Paul Lauterbur pioneered the first MR images and 9 years after the first human computed tomographic images were obtained. Historical advances in the research and clinical applications of MR imaging very much parallel the remarkable advances in MR imaging technology. These advances can be roughly classified into hardware (eg, magnets, gradients, radiofrequency [RF] coils, RF transmitter and receiver, MR imaging-compatible biopsy devices) and imaging techniques (eg, pulse sequences, parallel imaging, and so forth). Image quality has been dramatically improved with the introduction of high-field-strength superconducting magnets, digital RF systems, and phased-array coils. Hybrid systems, such as MR/positron emission tomography (PET), combine the superb anatomic and functional imaging capabilities of MR imaging with the unsurpassed capability of PET to demonstrate tissue metabolism. Supported by the improvements in hardware, advances in pulse sequence design and image reconstruction techniques have spurred dramatic improvements in imaging speed and the capability for studying tissue function. In this historical review, the history of MR imaging technology and developing research and clinical applications, as seen through the pages of Radiology, will be considered.

  5. Flair MR imaging in the Detection of subarachnoid hemorrhage : comparison with CT and T1-weighted MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Min, Soo Hyun; Kim, Soo Youn; Lee, Ghi Jai; Shim, Jae Chan; Oh, Tae Kyung; Kim, Ho Kyun [College of Medicine, Jnje University, Seoul (Korea, Republic of)

    2000-03-01

    To compare the findings of fluid-attenuated inversion recovery (FLAIR) MR imaging in the detection of subarachnoid hemorrhage (SAH), with those of precontrast CT and T1-weighted MR imaging. In 13 patients (14 cases) with SAH, FLAIR MR images were retrospectively analyzed and compared with CT (10 patients, 11 cases) and T1-weighted MR images (9 cases). SAH was confirmed on the basis of high density along the subarachnoid space, as seen on precontrast CT, or lumbar puncture. MR imaging was performed on a 1.0T unit. FLAIR MR and CT images were obtained during the acute stage(less than 3 days after ictus) in 10 and 9 cases, respectively, during the subacute stage (4-14 days after ictus) in two cases and one, respectively, and during the chronic stage (more than 15 days after ictus) in two cases and one, respectively. CT was performed before FLAIR MR imaging, and the interval between CT and FLAIR ranged from 24 hours (6 cases) to 2-3 (2 cases) or 4-7 days (3 cases). In each study, the conspicuity of visualization of SAH was graded as excellent, good, fair, or negative at five locations (sylvian fissure, cortical sulci, anterior basal cistern, posterior basal cistern, and perimesencephalic cistern). In all cases, subarachnoid hemorrhages were demonstrated as high signal intensity areas on FLAIR images. The detection rates for SAH on CT and T1-weighted MR images were 100% (11/11) and 89% (8/9), respectively. FLAIR was superior to T1-weighted imaging in the detection of SAH at all sites except the anterior basal cistern (p less than 0.05) and superior to CT in the detection of SAH at the cortical sulci (p less than 0.05). On FLAIR MR images, subarachnoid hemorrhages at all stages are demonstrated as high signal intensity areas; the FLAIR MR sequence is thus considered useful in the detection of SAH. In particular FLAIR is more sensitive than CT for the detection of SAH in the cortical sulci. (author)

  6. Gray matter changes in right superior temporal gyrus in criminal psychopaths. Evidence from voxel-based morphometry.

    Science.gov (United States)

    Müller, Jürgen L; Gänssbauer, Susanne; Sommer, Monika; Döhnel, Katrin; Weber, Tatjana; Schmidt-Wilcke, Tobias; Hajak, Göran

    2008-08-30

    "Psychopathy" according to the PCL-R describes a specific subgroup of antisocial personality disorder with a high risk for criminal relapses. Lesion and imaging studies point towards frontal or temporal brain regions connected with disturbed social behavior, antisocial personality disorder (APD) and psychopathy. Morphologically, some studies described a reduced prefrontal brain volume, whereas others reported on temporal lobe atrophy. To further investigate whether participants with psychopathy according to the Psychopathy Checklist-Revised Version (PCL-R) show abnormalities in brain structure, we used voxel-based morphometry (VBM) to investigate region-specific changes in gray matter in 17 forensic male inpatients with high PCL-R scores (PCL-R>28) and 17 male control subjects with low PCL-R scores (PCLright superior temporal gyrus. This is the first study to show that psychopathy is associated with a decrease in gray matter in both frontal and temporal brain regions, in particular in the right superior temporal gyrus, supporting the hypothesis that a disturbed frontotemporal network is critically involved in the pathogenesis of psychopathy.

  7. MR imaging of kidneys: functional evaluation using F-15 perfusion imaging

    International Nuclear Information System (INIS)

    Grattan-Smith, J. Damien; Jones, Richard A.; Little, Stephen; Perez-Bayfield, Marcos R.; Broecker, Bruce; Smith, Edwin A.; Scherz, Hal C.; Kirsch, Andrew J.

    2003-01-01

    Children with hydronephrosis are typically investigated by a combination of diuretic renal scintigraphy, ultrasound, and voiding cystourethrography. Unfortunately, there is no gold standard to assess obstruction. The purpose of our study was to evaluate the utility of dynamic contrast enhanced MR urography in the investigation of children with hydronephrosis to define urinary tract anatomy, to calculate differential renal function and to assess urinary tract obstruction. Dynamic contrast-enhanced MR imaging was performed in 40 children with unilateral hydronephrosis. There were 14 girls and 26 boys with an age range of 1 month to 14 years (mean 1.4 years). The information from traditional imaging modalities was compared to the information obtained from the single MR study. The anatomic imaging with MR urography was superior to other modalities. The split renal function was estimated with MR urography by calculating the volume of enhancing renal parenchyma and was comparable to renal scintigraphy (r=0.98). By using surgery versus non-surgery as the decision point, with MR urography the sensitivity was 100%, specificity 71%, positive predictive value 86%, negative predictive value 100%, and diagnostic efficiency 90%. For renal scintigraphy the sensitivity was 96%, the specificity 56%, positive predictive value 76%, negative predictive value 90%, and diagnostic efficiency 79%. Dynamic contrast-enhanced MR urography provides superior anatomic and functional information when compared with ultrasound and diuretic renal scintigraphy. The information is gathered in a single study that does not use ionizing radiation. It is likely that MR urography will replace renal scintigraphy in the evaluation of hydronephrosis in children. (orig.)

  8. MR imaging of kidneys: functional evaluation using F-15 perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Grattan-Smith, J. Damien; Jones, Richard A.; Little, Stephen [Department of Pediatric Radiology, Children' s Healthcare of Atlanta, Emory University School of Medicine, 1001 Johnson Ferry Road, GA 30342, Atlanta (United States); Perez-Bayfield, Marcos R.; Broecker, Bruce; Smith, Edwin A.; Scherz, Hal C.; Kirsch, Andrew J. [Department of Pediatric Urology, Children' s Healthcare of Atlanta, Emory University School of Medicine, GA 30342, Atlanta (United States)

    2003-05-01

    Children with hydronephrosis are typically investigated by a combination of diuretic renal scintigraphy, ultrasound, and voiding cystourethrography. Unfortunately, there is no gold standard to assess obstruction. The purpose of our study was to evaluate the utility of dynamic contrast enhanced MR urography in the investigation of children with hydronephrosis to define urinary tract anatomy, to calculate differential renal function and to assess urinary tract obstruction. Dynamic contrast-enhanced MR imaging was performed in 40 children with unilateral hydronephrosis. There were 14 girls and 26 boys with an age range of 1 month to 14 years (mean 1.4 years). The information from traditional imaging modalities was compared to the information obtained from the single MR study. The anatomic imaging with MR urography was superior to other modalities. The split renal function was estimated with MR urography by calculating the volume of enhancing renal parenchyma and was comparable to renal scintigraphy (r=0.98). By using surgery versus non-surgery as the decision point, with MR urography the sensitivity was 100%, specificity 71%, positive predictive value 86%, negative predictive value 100%, and diagnostic efficiency 90%. For renal scintigraphy the sensitivity was 96%, the specificity 56%, positive predictive value 76%, negative predictive value 90%, and diagnostic efficiency 79%. Dynamic contrast-enhanced MR urography provides superior anatomic and functional information when compared with ultrasound and diuretic renal scintigraphy. The information is gathered in a single study that does not use ionizing radiation. It is likely that MR urography will replace renal scintigraphy in the evaluation of hydronephrosis in children. (orig.)

  9. Magnetic resonance imaging of the visual pathway - anatomical and technical considerations

    International Nuclear Information System (INIS)

    Sosnowski, P.; Paprzycki, W.

    1993-01-01

    Magnetic resonance tomography creates possibility of imaging the whole visual pathway and is superior to CT. Plenitude of MR techniques can sometimes be the reason of unnecessary prolongation of the examination. This study tries to evaluate usefulness of different MR techniques and planes for optimal imaging of consecutive sections of visual pathway. (author)

  10. MR imaging of neonatal cerebral infarction

    International Nuclear Information System (INIS)

    McArdle, C.B.; Mehta, S.D.; Kulkarni, M.V.; Keeney, S.A.; Hayden, C.K.; Adcock, E.W. III.

    1987-01-01

    Twenty-six neonatal infarcts were imaged with 0.6 T and 1.5-T magnets and correlated with US and/or CT. Periventricular leukomalacia (PVL) was seen in six cases: lobar infarction, ten cases; global infarction, six cases; and basal ganglia infarction, four cases. MR imaging was superior to US and CT in detecting hemorrhagic PVL and basal ganglia infarcts. MR demonstrates lobar infarcts better than US and CT because of a wider field of view, specificty, and improved gray and white matter differentiation. US underestimates the extent of brain destruction in global infarcts. These results indicate that MR is the single best imaging modality for detecting ischemic brain injury

  11. Acute Superior Mesenteric Venous Thrombosis: Transcatheter Thrombolysis and Aspiration Thrombectomy Therapy by Combined Route of Superior Mesenteric Vein and Artery in Eight Patients

    International Nuclear Information System (INIS)

    Yang, Shuofei; Liu, Baochen; Ding, Weiwei; He, Changsheng; Wu, Xingjiang; Li, Jieshou

    2015-01-01

    PurposeTo assess the feasibility, effectiveness, and safety of catheter-directed thrombolysis and aspiration thrombectomy therapy by combined route of superior mesenteric vein and artery (SMV+SMA) for acute superior mesenteric venous thrombosis (ASMVT).MethodsThis retrospective study reviewed eight ASMVT patients with transcatheter direct thrombolysis and aspiration thrombectomy therapy via SMV and indirect thrombolysis via SMA during a period of 14 months. The demographics, etiology, risk factors, therapeutic effect, complications, mortality, and follow-up of the study population were assessed. Anatomic and imaging classification of location and extent of thrombus at diagnosis and degree of thrombus lysis were described.ResultsTechnical success was achieved with substantial improvement in symptoms and thrombus resolution after thrombolytic therapy in all patients. The local urokinase infusion by SMA and SMV was performed for 5–7 (6.13 ± 0.83) and 7–15 (12 ± 2.51) days. Anticoagulation was performed catheter-directed and then orally throughout hospitalization and after discharge. Four patients required delayed localized bowel resection after thrombolytic therapy with no death. Thrombolytic therapy was not interrupted despite minor bleeding at the puncture site in two patients and sepsis in another two postoperatively. Nearly complete removal of thrombus was demonstrated by contrast-enhanced CT scan and portography before discharge. Patients were discharged in 10–27 (19.25 ± 4.89) days after admission. No recurrence developed during the follow-up of 10–13 (12.13 ± 0.99) months.ConclusionsCatheter-directed thrombolytic and aspiration therapy via SMV+SMA is beneficial for ASMVT in avoiding patient death, efficient resolving thrombus, rapid improving symptoms, reversing extensive intestinal ischemia, averting bowel resection, or localizing infarcted bowel segment and preventing short bowel syndrome

  12. Acute Superior Mesenteric Venous Thrombosis: Transcatheter Thrombolysis and Aspiration Thrombectomy Therapy by Combined Route of Superior Mesenteric Vein and Artery in Eight Patients

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Shuofei, E-mail: yangshuofei@gmail.com; Liu, Baochen, E-mail: 306446264@qq.com; Ding, Weiwei, E-mail: dingwei-nju@hotmail.com; He, Changsheng, E-mail: hechsh@163.com; Wu, Xingjiang, E-mail: wuxingjiang@sohu.com; Li, Jieshou, E-mail: lijieshou2013@sohu.com [Research Institute of General Surgery, Jinling Hospital, Medical School of Nanjing University (China)

    2015-02-15

    PurposeTo assess the feasibility, effectiveness, and safety of catheter-directed thrombolysis and aspiration thrombectomy therapy by combined route of superior mesenteric vein and artery (SMV+SMA) for acute superior mesenteric venous thrombosis (ASMVT).MethodsThis retrospective study reviewed eight ASMVT patients with transcatheter direct thrombolysis and aspiration thrombectomy therapy via SMV and indirect thrombolysis via SMA during a period of 14 months. The demographics, etiology, risk factors, therapeutic effect, complications, mortality, and follow-up of the study population were assessed. Anatomic and imaging classification of location and extent of thrombus at diagnosis and degree of thrombus lysis were described.ResultsTechnical success was achieved with substantial improvement in symptoms and thrombus resolution after thrombolytic therapy in all patients. The local urokinase infusion by SMA and SMV was performed for 5–7 (6.13 ± 0.83) and 7–15 (12 ± 2.51) days. Anticoagulation was performed catheter-directed and then orally throughout hospitalization and after discharge. Four patients required delayed localized bowel resection after thrombolytic therapy with no death. Thrombolytic therapy was not interrupted despite minor bleeding at the puncture site in two patients and sepsis in another two postoperatively. Nearly complete removal of thrombus was demonstrated by contrast-enhanced CT scan and portography before discharge. Patients were discharged in 10–27 (19.25 ± 4.89) days after admission. No recurrence developed during the follow-up of 10–13 (12.13 ± 0.99) months.ConclusionsCatheter-directed thrombolytic and aspiration therapy via SMV+SMA is beneficial for ASMVT in avoiding patient death, efficient resolving thrombus, rapid improving symptoms, reversing extensive intestinal ischemia, averting bowel resection, or localizing infarcted bowel segment and preventing short bowel syndrome.

  13. Application of phase contrast imaging to mammography

    International Nuclear Information System (INIS)

    Tohyama, Keiko; Yamada, Katsuhiko; Katafuchi, Tetsuro; Matsuo, Satoru; Morishita, Junji

    2005-01-01

    Phase contrast images were obtained experimentally by using a customized mammography unit with a nominal focal spot size of 100 μm and variable source-to-image distances of up to 1.5 m. The purpose of this study was to examine the applicability and potential usefulness of phase contrast imaging for mammography. A mammography phantom (ACR156 RMI phantom) was imaged, and its visibility was examined. The optical density of the phantom images was adjusted to approximately 1.3 for both the contact and phase contrast images. Forty-one observers (18 medical doctors and 23 radiological technologists) participated in visual evaluation of the images. Results showed that, in comparison with the images of contact mammography, the phantom images of phase contrast imaging demonstrated statistically significantly superior visibility for fibers, clustered micro-calcifications, and masses. Therefore, phase contrast imaging obtained by using the customized mammography unit would be useful for improving diagnostic accuracy in mammography. (author)

  14. Radiografia intraoral e convencional da hemiarcada superior direita de gatos domésticos Intraoral and convencional radiography of the right maxilla hemiarcade of domestic cats

    Directory of Open Access Journals (Sweden)

    A.C. Nepomuceno

    2013-02-01

    Full Text Available A proposta com este trabalho foi avaliar a hemiarcada superior direita de gatos domésticos por meio de técnicas radiográficas odontológicas do paralelismo, empregando-se filmes intraorais aos posicionadores de Han Shin. As imagens obtidas por essa metodologia foram correlacionadas com as técnicas radiográficas convencionais (extraorais, com o intuito de se estabelecerem vantagens ou desvantagens para detectar possíveis afecções dentais e periodontais. Foram utilizados 30 gatos, sem raça definida, 17 machos e 13 fêmeas, faixa etária entre um e três anos, confinados em gatis do Departamento de Zootecnia da Universidade Federal de Lavras/MG. Com os animais sob anestesia geral, foram realizadas radiografias da hemiarcada superior direita, incluindo três incisivos, um canino, três pré-molares e um molar em radiografias intraorais e extraorais. As imagens radiográficas foram analisadas e efetuaram-se comparações qualitativas entre pares intraorais e convencionais dos mesmos animais. Para se estabelecer a técnica radiográfica dental mais bem adaptada, foram realizadas análises estatísticas pelo teste de McNemar (qui-quadrado modificado. A técnica intraoral mostrou ser superior à extraoral (PThe aim of this research was to evaluate the right maxilla hemiarcade of cats through parallel dental radiographic techniques, applying Han Shin intraoral film positioner. Images obtained with this method were correlated with conventional radiographic techniques (extraoral. The goal was to establish the advantages and disadvantages to detect possible dental and periodontal diseases. Thirty mixed breed cats were evaluated, 17 males and 13 females, ages one to three years old, confined in catteries in the Department of Zootecnia of the Federal University of Lavras/MG. Radiographies of the right maxilla were taken with the animals under general anesthesia, and three incisors, one canine, three premolars and one molar teeth were included in the

  15. The Effects of Triggering Mechanisms on the Energy Absorption Capability of Circular Jute/Epoxy Composite Tubes under Quasi-Static Axial Loading

    Science.gov (United States)

    Sivagurunathan, Rubentheran; Lau Tze Way, Saijod; Sivagurunathan, Linkesvaran; Yaakob, Mohd. Yuhazri

    2018-01-01

    The usage of composite materials have been improving over the years due to its superior mechanical properties such as high tensile strength, high energy absorption capability, and corrosion resistance. In this present study, the energy absorption capability of circular jute/epoxy composite tubes were tested and evaluated. To induce the progressive crushing of the composite tubes, four different types of triggering mechanisms were used which were the non-trigger, single chamfered trigger, double chamfered trigger and tulip trigger. Quasi-static axial loading test was carried out to understand the deformation patterns and the load-displacement characteristics for each composite tube. Besides that, the influence of energy absorption, crush force efficiency, peak load, mean load and load-displacement history were examined and discussed. The primary results displayed a significant influence on the energy absorption capability provided that stable progressive crushing occurred mostly in the triggered tubes compared to the non-triggered tubes. Overall, the tulip trigger configuration attributed the highest energy absorption.

  16. Micromachined Integrated Transducers for Ultrasound Imaging

    DEFF Research Database (Denmark)

    la Cour, Mette Funding

    The purpose of this project is to develop capacitive micromachined ultrasonic transducers (CMUTs) for medical imaging. Medical ultrasound transducers used today are fabricated using piezoelectric materials and bulk processing. To fabricate transducers capable of delivering a higher imaging...

  17. Noise management to achieve superiority in quantum information systems.

    Science.gov (United States)

    Nemoto, Kae; Devitt, Simon; Munro, William J

    2017-08-06

    Quantum information systems are expected to exhibit superiority compared with their classical counterparts. This superiority arises from the quantum coherences present in these quantum systems, which are obviously absent in classical ones. To exploit such quantum coherences, it is essential to control the phase information in the quantum state. The phase is analogue in nature, rather than binary. This makes quantum information technology fundamentally different from our classical digital information technology. In this paper, we analyse error sources and illustrate how these errors must be managed for the system to achieve the required fidelity and a quantum superiority.This article is part of the themed issue 'Quantum technology for the 21st century'. © 2017 The Author(s).

  18. Noise management to achieve superiority in quantum information systems

    Science.gov (United States)

    Nemoto, Kae; Devitt, Simon; Munro, William J.

    2017-06-01

    Quantum information systems are expected to exhibit superiority compared with their classical counterparts. This superiority arises from the quantum coherences present in these quantum systems, which are obviously absent in classical ones. To exploit such quantum coherences, it is essential to control the phase information in the quantum state. The phase is analogue in nature, rather than binary. This makes quantum information technology fundamentally different from our classical digital information technology. In this paper, we analyse error sources and illustrate how these errors must be managed for the system to achieve the required fidelity and a quantum superiority. This article is part of the themed issue 'Quantum technology for the 21st century'.

  19. Hierarchical image segmentation for learning object priors

    Energy Technology Data Exchange (ETDEWEB)

    Prasad, Lakshman [Los Alamos National Laboratory; Yang, Xingwei [TEMPLE UNIV.; Latecki, Longin J [TEMPLE UNIV.; Li, Nan [TEMPLE UNIV.

    2010-11-10

    The proposed segmentation approach naturally combines experience based and image based information. The experience based information is obtained by training a classifier for each object class. For a given test image, the result of each classifier is represented as a probability map. The final segmentation is obtained with a hierarchial image segmentation algorithm that considers both the probability maps and the image features such as color and edge strength. We also utilize image region hierarchy to obtain not only local but also semi-global features as input to the classifiers. Moreover, to get robust probability maps, we take into account the region context information by averaging the probability maps over different levels of the hierarchical segmentation algorithm. The obtained segmentation results are superior to the state-of-the-art supervised image segmentation algorithms.

  20. MR imaging of soft-tissue masses

    International Nuclear Information System (INIS)

    Fujimoto, H.; Murakami, K.; Ichikawa, T.; Matsubara, T.; Tsumurai, Y.; Masuda, S.; Terauchi, M.; Ozawa, K.; Arimizu, N.

    1990-01-01

    This paper evaluates the ability of T2*-weighted gradient-field-echo (T2*FE) MR imaging to image soft-tissue masses. The series included 26 cases, including 17 benign tumors, four malignant tumors, and five others. Images were obtained on a 0.5-T magnet with T2*FE imaging (300/22 [repetition time msec/echo time msec], 20 degree). Results were compared with those of T1-weighted spin-echo (SE) images (500/20--40) and T2-weighted SE (T2SE) images (2,000/80). T2*FE images were similar to T2SE images with respect to the signal intensity and internal architecture of the masses in many cases. In some instances, they were superior to T2SE images in depicting special features such as a hemosiderin deposit or in delineating the masses and adjacent fat tissues. Shorter (about one-third or two-thirds) scanning time was required to obtain T2*FE images than to obtain T2SE images