WorldWideScience

Sample records for super highly sensitive

  1. Super Sensitive Mass Detection in Nonlinear Regime

    Science.gov (United States)

    Azizi, Saber; Ahmadian, Iman; Cetinkaya, Cetin; Rezazadeh, Ghader

    2015-11-01

    Nonlinear dynamics of a clamped-clamped micro-beam exposed to a two sided electrostatic actuation is investigated to determine super sensitive regions for mass detection. The objective is to investigate the sensitivity of the frequency spectrum of various regions in the phase space to the added mass and force the system to operate in its super sensitive regions by applying an appropriate pulse to its control electrodes. The electrostatic actuation in the top electrode is a combination of a DC, AC and a pulse voltage, the excitation on the lower electrode is only a DC and a pulse voltage. The governing equation of the motion, derived using the Hamiltonian principle, is discretized to an equivalent single-degree of freedom system using the Galerkin method. Depending on the applied electrostatic voltage to the micro-beam, it is demonstrated that the number and types of equilibrium points of the system can be modified. In this study, the level of the DC electrostatic voltage is chosen such a way that the system has three equilibrium points including two centers and a saddle node where the homoclinic orbit originates. According to the reported results, the mass sensing sensitivity depends on the operating orbit; some orbits exhibit considerably higher mass detection sensitivity to the added mass compared to that of a typical quartz crystal micro balance instrument.

  2. Projected Sensitivity of the SuperCDMS SNOLAB experiment

    CERN Document Server

    Agnese, R; Aramaki, T; Arnquist, I; Baker, W; Barker, D; Thakur, R Basu; Bauer, D A; Borgland, A; Bowles, M A; Brink, P L; Bunker, R; Cabrera, B; Caldwell, D O; Calkins, R; Cartaro, C; Cerdeño, D G; Chagani, H; Chen, Y; Cooley, J; Cornell, B; Cushman, P; Daal, M; Di Stefano, P C F; Doughty, T; Esteban, L; Fallows, S; Figueroa-Feliciano, E; Fritts, M; Gerbier, G; Ghaith, M; Godfrey, G L; Golwala, S R; Hall, J; Harris, H R; Hofer, T; Holmgren, D; Hong, Z; Hoppe, E; Hsu, L; Huber, M E; Iyer, V; Jardin, D; Jastram, A; Kelsey, M H; Kennedy, A; Kubik, A; Kurinsky, N A; Leder, A; Loer, B; Asamar, E Lopez; Lukens, P; Mahapatra, R; Mandic, V; Mast, N; Mirabolfathi, N; Moffatt, R A; Mendoza, J D Morales; Orrell, J L; Oser, S M; Page, K; Page, W A; Partridge, R; Pepin, M; Phipps, A; Poudel, S; Pyle, M; Qiu, H; Rau, W; Redl, P; Reisetter, A; Roberts, A; Robinson, A E; Rogers, H E; Saab, T; Sadoulet, B; Sander, J; Schneck, K; Schnee, R W; Serfass, B; Speller, D; Stein, M; Street, J; Tanaka, H A; Toback, D; Underwood, R; Villano, A N; von Krosigk, B; Welliver, B; Wilson, J S; Wright, D H; Yellin, S; Yen, J J; Young, B A; Zhang, X; Zhao, X

    2016-01-01

    SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass ( 5 GeV/c$^2$). The mix of detector types (HV and iZIP), and targets (germanium and silicon), planned for the experiment, as well as flexibility in how the detectors are operated, will allow us to maximize the low-mass reach, and understand the backgrounds that the experiment will encounter. Upgrades to the experiment, perhaps with a variety of ultra-low-background cryogenic detectors, will extend dark matter sensitivity down to the "neutrino floor", where coherent scatters of solar neutrinos become a limiting background.

  3. Super-SERS-active and highly effective antimicrobial Ag nanodendrites

    Science.gov (United States)

    Li, H. B.; Liu, P.; Liang, Y.; Xiao, J.; Yang, G. W.

    2012-07-01

    We have developed simple and green electrochemistry to synthesize Ag nanostructures with high purity, good crystallinity and smooth surface for applications as super-SERS (surface-enhanced Raman scattering), SERS-active substrates and with highly effective antimicrobial activities. This synthesis takes place in a clean and slow reaction environment without any chemical additives, which ensures an ultrahigh active surface of the as-synthesized Ag nanostructures owing to their purity, good crystallinity and smooth morphology. Using this method, we synthesized nearly perfect Ag nanodendrites (NDs), which exhibit super-SERS sensitivity when they are used to detect the SERS spectra of rhodamine 6G at concentrations as low as 5 × 10-16 M, and have an ultrahigh electromagnetic (EM) enhancement factor of the order of 1013, breaking through the theoretical limit of EM enhancement. Meanwhile, the as-synthesized Ag NDs possess highly effective antimicrobial activities for Escherichia coli, Candida albicans and Staphylococcus aureus, which are over 10 times that of silver nanoparticles. Additionally, the basic physics and chemistry involved in the fabrication of Ag nanostructures are pursued. These investigations show that silver nanostructures with highly active surfaces can make the most of Ag nanostructures functioning as super-SERS-active substrates and multiple antibiotics.

  4. Projected sensitivity of the SuperCDMS SNOLAB experiment

    Energy Technology Data Exchange (ETDEWEB)

    Agnese, R.; Anderson, A. J.; Aramaki, T.; Arnquist, I.; Baker, W.; Barker, D.; Basu Thakur, R.; Bauer, D. A.; Borgland, A.; Bowles, M. A.; Brink, P. L.; Bunker, R.; Cabrera, B.; Caldwell, D. O.; Calkins, R.; Cartaro, C.; Cerdeño, D. G.; Chagani, H.; Chen, Y.; Cooley, J.; Cornell, B.; Cushman, P.; Daal, M.; Di Stefano, P. C. F.; Doughty, T.; Esteban, L.; Fallows, S.; Figueroa-Feliciano, E.; Fritts, M.; Gerbier, G.; Ghaith, M.; Godfrey, G. L.; Golwala, S. R.; Hall, J.; Harris, H. R.; Hofer, T.; Holmgren, D.; Hong, Z.; Hoppe, E.; Hsu, L.; Huber, M. E.; Iyer, V.; Jardin, D.; Jastram, A.; Kelsey, M. H.; Kennedy, A.; Kubik, A.; Kurinsky, N. A.; Leder, A.; Loer, B.; Lopez Asamar, E.; Lukens, P.; Mahapatra, R.; Mandic, V.; Mast, N.; Mirabolfathi, N.; Moffatt, R. A.; Morales Mendoza, J. D.; Orrell, J. L.; Oser, S. M.; Page, K.; Page, W. A.; Partridge, R.; Pepin, M.; Phipps, A.; Poudel, S.; Pyle, M.; Qiu, H.; Rau, W.; Redl, P.; Reisetter, A.; Roberts, A.; Robinson, A. E.; Rogers, H. E.; Saab, T.; Sadoulet, B.; Sander, J.; Schneck, K.; Schnee, R. W.; Serfass, B.; Speller, D.; Stein, M.; Street, J.; Tanaka, H. A.; Toback, D.; Underwood, R.; Villano, A. N.; von Krosigk, B.; Welliver, B.; Wilson, J. S.; Wright, D. H.; Yellin, S.; Yen, J. J.; Young, B. A.; Zhang, X.; Zhao, X.

    2017-04-07

    SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$ for a dark matter particle mass of 1 GeV/c$^2$, and with capacity to continue exploration to both smaller masses and better sensitivities. The phonon sensitivity of the HV detectors will be sufficient to detect nuclear recoils from sub-GeV dark matter. A detailed calibration of the detector response to low energy recoils will be needed to optimize running conditions of the HV detectors and to interpret their data for dark matter searches. Low-activity shielding, and the depth of SNOLAB, will reduce most backgrounds, but cosmogenically produced $^{3}$H and naturally occurring $^{32}$Si will be present in the detectors at some level. Even if these backgrounds are x10 higher than expected, the science reach of the HV detectors would be over three orders of magnitude beyond current results for a dark matter mass of 1 GeV/c$^2$. The iZIP detectors are relatively insensitive to variations in detector response and backgrounds, and will provide better sensitivity for dark matter particle masses (> 5 GeV/c$^2$). The mix of detector types (HV and iZIP), and targets (germanium and silicon), planned for the experiment, as well as flexibility in how the detectors are operated, will allow us to maximize the low-mass reach, and understand the backgrounds that the experiment will encounter. Upgrades to the experiment, perhaps with a variety of ultra-low-background cryogenic detectors, will extend dark matter sensitivity down to the "neutrino floor", where coherent scatters of solar neutrinos become a limiting background.

  5. Projected Sensitivity of the SuperCDMS SNOLAB experiment

    Energy Technology Data Exchange (ETDEWEB)

    Agnese, R.; Anderson, A. J.; Aramaki, T.; Arnquist, Isaac J.; Baker, W.; Barker, D.; Basu Thakur, R.; Bauer, D. A.; Borgland, A.; Bowles, M. A.; Brink, Paul L.; Bunker, Raymond A.; Cabrera, B.; Caldwell, D. O.; Calkins, R.; Cartaro, C.; Cerdeno, D.; Chagani, H.; Chen, Y.; Cooley, J.; Cornell, B.; Cushman, Priscilla B.; Daal, M.; Di Stefano, P. C.; Doughty, T.; Esteban, L.; Fallows, S.; Figueroa-Feliciano, E.; Fritts, M.; Gerbier, G.; Ghaith, M.; Godfrey, G. L.; Golwala, S. R.; Hall, Jeter C.; Harris, H. R.; Hofer, T.; Holmgren, D.; Hong, Z.; Hoppe, Eric W.; Hsu, L.; Huber, M. E.; Iyer, V.; Jardin, D. M.; Jastram, A.; Kelsey, Michael H.; Kennedy, A.; Kubik, A.; Kurinsky, N. A.; Leder, A.; Loer, Ben M.; Lopez Asamar, E.; Lukens, P.; Mahapatra, R.; Mandic, V.; Mast, N.; Mirabolfathi, M.; Moffatt, R. A.; Morales Mendoza, J. D.; Orrell, John L.; Oser, S. M.; Page, K.; Page, W. A.; Partridge, R.; Pepin, M.; Phipps, A.; Poudel, S.; Pyle, M.; Qiu, H.; Rau, W.; Redl, P.; Reisetter, A.; Roberts, A.; Robinson, A. E.; Rogers, H. E.; Saab, T.; Sadoulet, B.; Sander, J.; Schneck, K.; Schnee, Richard W.; Serfass, B.; Speller, D.; Stein, M.; Street, Joseph; Tanaka, H.; Toback, D.; Underwood, Ryan; Villano, A. N.; Von Krosigk, B.; Welliver, B.; Wilson, J. S.; Wright, D. H.; Yellin, S.; Yen, J. J.; Young, B. A.; Zhang, X.; Zhao, X.

    2017-04-07

    SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass particles (with masses ≤ 10 GeV/c^2) that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ∼1×10^−43 cm^2 for a dark matter particle mass of 1 GeV/c^2, and with capacity to continue exploration to both smaller masses and better sensitivities. The phonon sensitivity of the HV detectors will be sufficient to detect nuclear recoils from sub-GeV dark matter. A detailed calibration of the detector response to low-energy recoils will be needed to optimize running conditions of the HV detectors and to interpret their data for dark matter searches. Low-activity shielding, and the depth of SNOLAB, will reduce most backgrounds, but cosmogenically produced H-3 and naturally occurring Si-32 will be present in the detectors at some level. Even if these backgrounds are 10 times higher than expected, the science reach of the HV detectors would be over 3 orders of magnitude beyond current results for a dark matter mass of 1 GeV/c^2. The iZIP detectors are relatively insensitive to variations in detector response and backgrounds, and will provide better sensitivity for dark matter particles with masses ≳5 GeV/c^2. The mix of detector types (HV and iZIP), and targets (germanium and silicon), planned for the experiment, as well as flexibility in how the detectors are operated, will allow us to maximize the low-mass reach, and understand the backgrounds that the experiment will encounter. Upgrades to the experiment, perhaps with a variety of ultra-low-background cryogenic detectors, will extend dark matter sensitivity down to the “neutrino floor,” where coherent scatters of solar neutrinos become a limiting background.

  6. Method and apparatus for connecting high voltage leads to a high temperature super-conducting transformer

    Science.gov (United States)

    Golner, Thomas M.; Mehta, Shirish P.

    2005-07-26

    A method and apparatus for connecting high voltage leads to a super-conducting transformer is provided that includes a first super-conducting coil set, a second super-conducting coil set, and a third super-conducting coil set. The first, second and third super-conducting coil sets are connected via an insulated interconnect system that includes insulated conductors and insulated connectors that are utilized to connect the first, second, and third super-conducting coil sets to the high voltage leads.

  7. What is so super about super-emitters? Characterizing methane high emitters from natural gas infrastructure

    Science.gov (United States)

    Zavala Araiza, D.; Lyon, D. R.; Alvarez, R.; Harriss, R. C.; Palacios, V.; Hamburg, S.

    2015-12-01

    Methane emissions across the natural gas supply chain are dominated at any one time by a few high-emitters (super-emitters or fat-tail of the distribution), often underrepresented in published datasets used to construct emission inventories. Characterization of high-emitters is essential for improving emission estimates based on atmospheric data (top-down) and emission inventories (bottom-up). The population of high-emitters (e.g. 10-20% of sites that account for 80-90% of the emissions) is temporally and spatially dynamic. As a consequence, it is challenging to design sampling methods and construct estimates that accurately represent their frequency and magnitude of emissions. We present new methods to derive facility-specific emission distribution functions that explicitly integrate the influence of the relatively rare super-emitters. These methods were applied in the Barnett Shale region to construct a custom emission inventory that is then compared to top-down emission estimates for the region. We offer a methodological framework relevant to the design of future sampling campaigns, in which these high-emitters are seamlessly incorporated to representative emissions distributions. This framework can be applied to heterogeneous oil and gas production regions across geographies to obtain accurate regional emission estimates. Additionally, we characterize emissions relative to the fraction of a facility's total methane throughput; an effective metric to identify sites with excess emissions resulting from avoidable operating conditions, such as malfunctioning equipment (defined here as functional super-emitters). This work suggests that identifying functional super-emitters and correcting their avoidable operating conditions would result in significant emission reductions. However, due to their spatiotemporal dynamic behavior, achieving and maintaining uniformly low emissions across the entire population of sites will require mitigation steps (e.g. leak detection

  8. Two-Dimensional Super High Density Multi-Fiber Connector

    Institute of Scientific and Technical Information of China (English)

    Takashi Shigenaga; Katsuki Suematsu; Masao Shinoda; Takayuki Ando

    2003-01-01

    We have developed 32-fiber and 60-fiber super high density multi fiber connector. This 32-fiber connector can be applicable for single-mode fiber and 60-fiber connector for multi-mode fiber. We have also established PC (physical contact) connection technology by optimizing polishing condition and clamping force.

  9. Super-sensitive Molecule-hugging Graphene Nanopores

    CERN Document Server

    Garaj, Slaven; Branton, Daniel; Golovchenko, Jene A

    2012-01-01

    Longitudinal resolution and lateral sensitivity are decisive characteristics that determine the suitability of a nanopore sensor for sequencing a strand of DNA as well as other important polymers. Previous modeling of DNA induced ionic current blockades in single atom thick graphene nanopores has shown these nanopores to have sufficient longitudinal resolution to distinguish individual nucleobases along the length of a DNA molecule. Here we experimentally focus on the sensitivity to small changes in DNA diameter that can be discerned with graphene nanopores. We show that remarkably large sensitivities (0.5 nA/A)are obtained when the nanopore is tailored to have a diameter close to that of the polymer of interest. Our results have been obtained with double-stranded DNA (dsDNA). Smaller graphene nanopores that can be tuned to the diameter of single-stranded DNA (ssDNA) for sequencing have only recently been demonstrated. Our results indicate that nanopore sensors based on such pores will provide excellent resol...

  10. Super-Sensitive and Robust Biosensors from Supported Polymer Bilayers

    Energy Technology Data Exchange (ETDEWEB)

    Paxton, Walter F. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    Biological organisms are potentially the most sensitive and selective biological detection systems known, yet we are currently severely limited in our ability to exploit biological interactions in sensory devices, due in part to the limited stability of biological systems and derived materials. This proposal addresses an important aspect of integrating biological sensory materials in a solid state device. If successful, such technology could enable entirely new classes of robust biosensors that could be miniaturized and deployed in the field. The critical aims of the proposed work were 1) the calibration of a more versatile approach to measuring pH, 2) the use of this method to monitor pH changes caused by the light-induced pumping of protons across vesicles with bacteriorhodopsin integrated into the membranes (either polymer or lipid); 3) the preparation of bilayer assemblies on platinum surfaces; 4) the enhanced detection of lightinduced pH changes driven by bR-loaded supported bilayers. I have developed a methodology that may enable that at interfaces and developed a methodology to characterize the functionality of bilayer membranes with reconstituted membrane proteins. The integrity of the supported bilayer films however must be optimized prior to the full realization of the work originally envisioned in the original proposal. Nevertheless, the work performed on this project and the encouraging results it has produced has demonstrated that these goals are challenging yet within reach.

  11. High-Sensitivity Spectrophotometry.

    Science.gov (United States)

    Harris, T. D.

    1982-01-01

    Selected high-sensitivity spectrophotometric methods are examined, and comparisons are made of their relative strengths and weaknesses and the circumstances for which each can best be applied. Methods include long path cells, noise reduction, laser intracavity absorption, thermocouple calorimetry, photoacoustic methods, and thermo-optical methods.…

  12. Highly Sensitive Optical Receivers

    CERN Document Server

    Schneider, Kerstin

    2006-01-01

    Highly Sensitive Optical Receivers primarily treats the circuit design of optical receivers with external photodiodes. Continuous-mode and burst-mode receivers are compared. The monograph first summarizes the basics of III/V photodetectors, transistor and noise models, bit-error rate, sensitivity and analog circuit design, thus enabling readers to understand the circuits described in the main part of the book. In order to cover the topic comprehensively, detailed descriptions of receivers for optical data communication in general and, in particular, optical burst-mode receivers in deep-sub-µm CMOS are presented. Numerous detailed and elaborate illustrations facilitate better understanding.

  13. Polarization sensitive localization based super-resolution microscopy with a birefringent wedge

    Science.gov (United States)

    Sinkó, József; Gajdos, Tamás; Czvik, Elvira; Szabó, Gábor; Erdélyi, Miklós

    2017-03-01

    A practical method has been presented for polarization sensitive localization based super-resolution microscopy using a birefringent dual wedge. The measurement of the polarization degree at the single molecule level can reveal the chemical and physical properties of the local environment of the fluorescent dye molecule and can hence provide information about the sub-diffraction sized structure of biological samples. Polarization sensitive STORM imaging of the F-Actins proved correlation between the orientation of fluorescent dipoles and the axis of the fibril.

  14. SuperB A High-Luminosity Asymmetric $e^+ e^-$ Super Flavour Factory : Conceptual Design Report

    CERN Document Server

    Bona, M.; Grauges Pous, E.; Colangelo, P.; De Fazio, F.; Palano, A.; Manghisoni, M.; Re, V.; Traversi, G.; Eigen, G.; Venturini, M.; Soni, N.; Bruschi, M.; De Castro, S.; Faccioli, P.; Gabrieli, A.; Giacobbe, B.; Semprini Cesare, N.; Spighi, R.; Villa, M.; Zoccoli, A.; Hearty, C.; McKenna, J.; Soni, A.; Khan, A.; Barniakov, A.Y.; Barniakov, M.Y.; Blinov, V.E.; Druzhinin, V.P.; Golubev, V.B.; Kononov, S.A.; Koop, I.A.; Kravchenko, E.A.; Levichev, E.B.; Nikitin, S.A.; Onuchin, A.P.; Piminov, P.A.; Serednyakov, S.I.; Shatilov, D.N.; Skovpen, Y.I.; Solodov, E.A.; Cheng, C.H.; Echenard, B.; Fang, F.; Hitlin, D.J.; Porter, F.C.; Asner, D.M.; Pham, T.N.; Fleischer, R.; Giudice, G.F.; Hurth, T.; Mangano, M.; Mancinelli, G.; Meadows, B.T.; Schwartz, A.J.; Sokoloff, M.D.; Soffer, A.; Beard, C.D.; Haas, T.; Mankel, R.; Hiller, G.; Ball, P.; Pappagallo, M.; Pennington, M.R.; Gradl, W.; Playfer, S.; Abada, A.; Becirevic, D.; Descotes-Genon, S.; Pene, O.; Andreotti, D.; Andreotti, M.; Bettoni, D.; Bozzi, C.; Calabresi, R.; Cecchi, A.; Cibinetto, G.; Franchini, P.; Luppi, E.; Negrini, M.; Petrella, A.; Piemontese, L.; Prencipe, E.; Santoro, V.; Stancari, G.; Anulli, F.; Baldini-Ferroli, R.; Biagini, M.E.; Boscolo, M.; Calcaterra, A.; Drago, A.; Finocchiaro, G.; Guiducci, S.; Isidori, G.; Pacetti, S.; Patteri, P.; Peruzzi, I.M.; Piccolo, M.; Preger, M.A.; Raimondi, P.; Rama, M.; Vaccarezza, C.; Zallo, A.; Zobov, M.; De Sangro, R.; Buzzo, A.; Lo Vetere, M.; Macri, M.; Monge, M.R.; Passaggio, S.; Patrignani, C.; Robutti, E.; Tosi, S.; Matias, J.; Panduro Vazquez, W.; Borzumati, F.; Eyges, V.; Prell, S.A.; Pedlar, T.K.; Korpar, S.; Pestonik, R.; Staric, M.; Neubert, M.; Denig, A.G.; Nierste, U.; Agoh, T.; Ohmi, K.; Ohnishi, Y.; Fry, J.R.; Touramanis, C.; Wolski, A.; Golob, B.; Krizan, P.; Flaecher, H.; Bevan, A.J.; Di Lodovico, F.; George, K.A.; Barlow, R.; Lafferty, G.; Jawahery, A.; Roberts, D.A.; Simi, G.; Patel, P.M.; Robertson, S.H.; Lazzaro, A.; Palombo, F.; Kaidalov, A.; Buras, A.J.; Tarantino, C.; Buchalla, G.; Sanda, A.I.; D'Ambrosio, G.; Ricciardi, G.; Bigi, I.; Jessop, C.P.; Losecco, J.M.; Honscheid, K.; Arnaud, N.; Chehab, R.; Fedala, Y.; Polci, F.; Roudeau, P.; Sordini, V.; Soskov, V.; Stocchi, A.; Variola, A.; Vivoli, A.; Wormser, G.; Zomer, F.; Bertolin, A.; Brugnera, R.; Gagliardi, N.; Gaz, A.; Margoni, M.; Morandin, M.; Posocco, M.; Rotondo, M.; Simonetto, F.; Stroili, R.; Bonneaud, G.R.; Lombardo, V.; Calderini, G.; Ratti, L.; Speziali, V.; Biasini, M.; Covarelli, R.; Manoni, E.; Servoli, L.; Angelini, C.; Batignani, G.; Bettarini, S.; Bosi, F.; Carpinelli, M.; Cenci, R.; Cervelli, A.; Dell'Orso, M.; Forti, F.; Giannetti, P.; Giorgi, M.; Lusiani, A.; Marchiori, G.; Massa, M.; Mazur, M.A.; Morsani, F.; Neri, N.; Paoloni, E.; Raffaelli, F.; Rizzo, G.; Walsh, J.; Braun, V.; Lenz, A.; Adams, G.S.; Danko, I.Z.; Baracchini, E.; Bellini, F.; Cavoto, G.; D'Orazio, A.; Del Re, D.; Di Marco, E.; Faccini, R.; Ferrarotto, F.; Gaspero, Mario; Jackson, P.; Martinelli, G.; Mazzoni, M.A.; Morganti, Silvio; Piredda, G.; Renga, F.; Silvestrini, L.; Voena, C.; Catani, L.; Di Ciaccio, A.; Messi, R.; Santovetti, E.; Satta, A.; Ciuchini, M.; Lubicz, V.; Wilson, F.F.; Godang, R.; Chen, X.; Liu, H.; Park, W.; Purohit, M.; Trivedi, A.; White, R.M.; Wilson, J.R.; Allen, M.T.; Aston, D.; Bartoldus, R.; Brodsky, S.J.; Cai, Y.; Coleman, J.; Convery, M.R.; DeBarger, S.; Dingfelder, J.C.; Dubois-Felsmann, G.P.; Ecklund, S.; Fisher, A.S.; Haller, G.; Heifets, S.A.; Kaminski, J.; Kelsey, M.H.; Kocian, M.L.; Leith, D.W.G.S.; Li, N.; Luitz, S.; Luth, V.; MacFarlane, D.; Messner, R.; Muller, D.R.; Nosochkov, Y.; Novokhatski, A.; Pivi, M.; Ratcliff, B.N.; Roodman, A.; Schwiening, J.; Seeman, J.; Snyder, A.; Sullivan, M.; Va'Vra, J.; Wienands, U.; Wisniewski, W.; Stoeck, H.; Cheng, H.Y.; Li, H.N.; Keum, Y.Y.; Gronau, M.; Grossman, Y.; Bianchi, F.; Gamba, D.; Gambino, P.; Marchetto, F.; Menichetti, Ezio A.; Mussa, R.; Pelliccioni, M.; Dalla Betta, G.F.; Bomben, M.; Bosisio, L.; Cartaro, C.; Lanceri, L.; Vitale, L.; Azzolini, V.; Bernabeu, J.; Lopez-March, N.; Martinez-Vidal, F.; Milanes, D.A.; Oyanguren, A.; Paradisi, P.; Pich, A.; Sanchis-Lozano, M.A.; Kowalewski, Robert V.; Roney, J.M.; Back, J.J.; Gershon, T.J.; Harrison, P.F.; Latham, T.E.; Mohanty, G.B.; Petrov, A.A.; Pierini, M.; INFN

    2007-01-01

    The physics objectives of SuperB, an asymmetric electron-positron collider with a luminosity above 10^36/cm^2/s are described, together with the conceptual design of a novel low emittance design that achieves this performance with wallplug power comparable to that of the current B Factories, and an upgraded detector capable of doing the physics in the SuperB environment.

  15. Extraordinary radiation super-sensitivity accompanying with sorafenib combination therapy: what lies beneath?

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ja Young; Lee, Ju Hye; Yoon, Han Bin; Lee, Ho Jeong; Jeon, Ho Sang; Nam, Ji Ho [Dept. of Radiation Oncology, Pusan National University Yangsan Hospital, Yangsan (Korea, Republic of)

    2017-06-15

    Primary liver tumor, especially hepatocellular carcinoma (HCC), is a common cause of cancer death worldwide. The incidence is generally higher in Asian countries than in western countries. Carcinogenesis of HCC is often associated with hepatitis viral infections. Current standard treatment of HCC is surgical resection or transplantation in patients with early stage disease. However, the patient with advanced stage disease, surgical resection is often limited. Sorafenib or other treatment modalities are not so effective as well. We report a case of unusual radiation super-sensitivity in advanced stage HCC, and review the literature.

  16. SuperB: a Linear High-Luminosity B Factory

    Energy Technology Data Exchange (ETDEWEB)

    Albert, J.; Bettarini, S.; Biagini, M.; Bonneaud, G.; Cai, Y.; Calderini, G.; Ciuchini, M.; Dubois-Felsmann, G.P.; Ecklund, S.; Forti, F.; Gershon, T.J.; Giorgi, M.A.; Hitlin, D.G.; Leith, D.W.G.S.; Lusiani, A.; MacFarlane, D.B.; Martinez-Vidal, F.; Neri, N.; Novokhatski, A.; Pierini, M.; Piredda, G.; /Caltech /Pisa U. /Pisa, Scuola Normale

    2006-02-08

    This paper is based on the outcome of the activity that has taken place during the recent workshop on ''SuperB in Italy'' held in Frascati on November 11-12, 2005. The workshop was opened by a theoretical introduction of Marco Ciuchini and was structured in two working groups. One focused on the machine and the other on the detector and experimental issues.. The present status on CP is mainly based on the results achieved by BABAR and Belle. Establishment of the indirect CP violation in B sector in 2001 and of the direct CP violation in 2004 thanks to the success of PEP-II and KEKB e{sup +}e{sup -} asymmetric B Factories operating at the center of mass energy corresponding to the mass of the {Upsilon}(4S ). With the two B Factories taking data, the Unitarity Triangle is now beginning to be over constrained by improving the measurements of the sides and now also of the angles {alpha}, and {gamma}. We are also in presence of the very intriguing results about the measurements of sin2{beta} in the time dependent analysis of decay channels via penguin loops, where b {yields} s{bar s}s and b {yields} s{bar d}d. {tau} physics, in particular LFV search, as well as charm and ISR physics are important parts of the scientific program of a SuperB Factory. The physics case together with possible scenarios for the high luminosity SuperB Factory based on the concepts of the Linear Collider and the related experimental issues are discussed.

  17. Ultra High Energy Cosmic Rays & Super-heavy Dark Matter

    CERN Document Server

    Marzola, Luca

    2016-01-01

    We reanalyse the prospects for upcoming Ultra-High Energy Cosmic Ray experiments in connection with the phenomenology of Super-heavy Dark Matter. We identify a set of observables well suited to reveal a possible anisotropy in the High Energy Cosmic Ray flux induced by the decays of these particles, and quantify their performance via Monte Carlo simulations that mimic the outcome of near-future and next-generation experiments. The spherical and circular dipoles are able to tell isotropic and anisotropic fluxes apart at a confidence level as large as $4\\sigma$ or $5\\sigma$, depending on the Dark Matter profile. The forward-to-backward flux ratio yields a comparable result for relatively large opening angles of about 40~deg, but it is less performing once a very large number of events is considered. We also find that an actual experiment employing these observables and collecting 300~events at 60~EeV would have a $50\\%$ chance of excluding isotropy against Super-heavy Dark Matter at a significance of at least $3...

  18. Photometric Redshifts for High Resolution Radio Galaxies in the SuperCLASS Field

    Science.gov (United States)

    Manning, Sinclaire; Casey, Caitlin; Battye, Richard; Hales, Christopher A.; Chapman, Scott; Smail, Ian; SuperCLASS Team

    2017-01-01

    SuperCLASS (the Super-Cluster Assisted Shear Survey) is a deep, wide-area (~2 square degrees) extragalactic field with high resolution (0.1”) radio continuum coverage from e-MERLIN (Multi-Element Radio Linked Interferometer Network.) The combination of sensitivity and spatial resolution make e-MERLIN an ideal tool to trace spatially resolved star-formation in heavily obscured, dusty star-forming galaxies (DSFGs). Plus, thanks to the tight relationship between radio continuum and far-IR observations we have an observationally inexpensive and accurate method of mapping star formation density in distant galaxies. We present a photometric redshift catalog for DSFGs located in the SuperCLASS field. Multiwavelength photometric data was obtained with Subaru SuprimeCam (B,V,r,i,z) and photometric redshifts were generated using the public photometric redshift code, EAZY. With these redshifts we aim to conduct the first large sample morphological analysis of z~1-3 obscured galaxies. We plan to address two important questions: 1) Are the majority of obscured SFR>50 Msolar/yr galaxies driven by major collisions? and 2) do luminous active galactic nuclei (AGN) play a crucial role in the quenching of highly obscured star-formation? These photometric redshifts are crucial in determining the physical origins of our DSFG sample and to also conduct radio weak lensing experiments with the e-MERLIN dataset.

  19. High temperature condensate clouds in super-hot Jupiter atmospheres

    CERN Document Server

    Wakeford, Hannah R; Lewis, Nikole K; Kataria, Tiffany; Marley, Mark S; Fortney, Jonathan J; Mandell, Avi M

    2016-01-01

    Deciphering the role of clouds is central to our understanding of exoplanet atmospheres, as they have a direct impact on the temperature and pressure structure, and observational properties of the planet. Super-hot Jupiters occupy a temperature regime similar to low mass M-dwarfs, where minimal cloud condensation is expected. However, observations of exoplanets such as WASP-12b (Teq ~ 2500 K) result in a transmission spectrum indicative of a cloudy atmosphere. We re-examine the temperature and pressure space occupied by these super-hot Jupiter atmospheres, to explore the role of the initial Al- and Ti-bearing condensates as the main source of cloud material. Due to the high temperatures a majority of the more common refractory material is not depleted into deeper layers and would remain in the vapor phase. The lack of depletion into deeper layers means that these materials with relatively low cloud masses can become significant absorbers in the upper atmosphere. We provide condensation curves for the initial ...

  20. An angle encoder for super-high resolution and super-high accuracy using SelfA

    Science.gov (United States)

    Watanabe, Tsukasa; Kon, Masahito; Nabeshima, Nobuo; Taniguchi, Kayoko

    2014-06-01

    Angular measurement technology at high resolution for applications such as in hard disk drive manufacturing machines, precision measurement equipment and aspherical process machines requires a rotary encoder with high accuracy, high resolution and high response speed. However, a rotary encoder has angular deviation factors during operation due to scale error or installation error. It has been assumed to be impossible to achieve accuracy below 0.1″ in angular measurement or control after the installation onto the rotating axis. Self-calibration (Lu and Trumper 2007 CIRP Ann. 56 499; Kim et al 2011 Proc. MacroScale; Probst 2008 Meas. Sci. Technol. 19 015101; Probst et al Meas. Sci. Technol. 9 1059; Tadashi and Makoto 1993 J. Robot. Mechatronics 5 448; Ralf et al 2006 Meas. Sci. Technol. 17 2811) and cross-calibration (Probst et al 1998 Meas. Sci. Technol. 9 1059; Just et al 2009 Precis. Eng. 33 530; Burnashev 2013 Quantum Electron. 43 130) technologies for a rotary encoder have been actively discussed on the basis of the principle of circular closure. This discussion prompted the development of rotary tables which achieve reliable and high accuracy angular verification. We apply these technologies for the development of a rotary encoder not only to meet the requirement of super-high accuracy but also to meet that of super-high resolution. This paper presents the development of an encoder with 221 = 2097 152 resolutions per rotation (360°), that is, corresponding to a 0.62″ signal period, achieved by the combination of a laser rotary encoder supplied by Magnescale Co., Ltd and a self-calibratable encoder (SelfA) supplied by The National Institute of Advanced Industrial Science & Technology (AIST). In addition, this paper introduces the development of a rotary encoder to guarantee ±0.03″ accuracy at any point of the interpolated signal, with respect to the encoder at the minimum resolution of 233, that is, corresponding to a 0.0015″ signal period after

  1. SuperB: A High-Luminosity Asymmetric e+e- Super Flavor Factory

    Energy Technology Data Exchange (ETDEWEB)

    Bona, M.; /et al.

    2007-05-18

    We discuss herein the exciting physics program that can be accomplished with a very large sample of heavy quark and heavy lepton decays produced in the very clean environment of an e{sup +}e{sup -} collider; a program complementary to that of an experiment such as LHCb at a hadronic machine. It then presents the conceptual design of a new type of e{sup +}e{sup -} collider that produces a nearly two-order-of-magnitude increase in luminosity over the current generation of asymmetric B Factories. The key idea is the use of low emittance beams produced in an accelerator lattice derived from the ILC Damping Ring Design, together with a new collision region, again with roots in the ILC final focus design, but with important new concepts developed in this design effort. Remarkably, SuperB produces this very large improvement in luminosity with circulating currents and wallplug power similar to those of the current B Factories. There is clear synergy with ILC R&D; design efforts have already influenced one another, and many aspects of the ILC Damping Rings and Final Focus would be operationally tested at SuperB. Finally, the design of an appropriate detector, based on an upgrade of BABAR as an example, is discussed in some detail. A preliminary cost estimate is presented, as is an example construction timeline.

  2. Advances and Prospects in Breeding Japonica Rice for Super High Yield in the Northern China

    Institute of Scientific and Technical Information of China (English)

    CHEN Wen-fu; XU Zheng-jin; ZHANG Wen-zhong

    2007-01-01

    In this paper, advances and prospects in breeding japonica rice for super high yield in the northern China were analyzed comprehensively in terms of breeding theories, techniques and practices. The author holds that developing and spreading super rice is an important way to enhance the overall yielding ability of japonica rice and attaining immense expansion of rice production. After theories and technical guidelines for super rice breeding were formulated, which involved the creation of new plant morphology and strong hybrid vigor through crossing indica with japonica subspecies, the optimization of combination of desirable traits via multiple crossing or backcrossing, the assemblage of favorable genes and the integration of ideal plant morphology with the utilization of vigor-major breakthroughs have been made in conventional breeding of japonica super rice. A batch of new super rice varieties marked by superior rice quality and high disease resistance, such as Shennong 265, Shennong 606, and Jijing 88, etc., have been developed and released. In comparison with the advancement in conventional breeding of super rice, progress in hybrid japonica super rice breeding is slower because of climatic and ecological constraint in northern China. Therefore, solving the contradictions between vigor and growth duration, between yield and rice quality, and boosting vastly seed production are still serious challenges for breeders of hybrid japonica rice. Physiological and genetic problems in japonica super rice breeding are also discussed in this paper.

  3. Fast Super-Resolution Imaging with Ultra-High Labeling Density Achieved by Joint Tagging Super-Resolution Optical Fluctuation Imaging (JT-SOFI)

    CERN Document Server

    Zeng, Zhiping; Wang, Hening; Huang, Ning; Shan, Chunyan; Zhang, Hao; Teng, Junlin; Xi, Peng

    2015-01-01

    Previous stochastic localization-based super-resolution techniques are largely limited by the labeling density and the fidelity to the morphology of specimen. We report on an optical super-resolution imaging scheme implementing joint tagging using multiple fluorescent blinking dyes associated with super-resolution optical fluctuation imaging (JT-SOFI), achieving ultra-high labeling density super-resolution imaging. To demonstrate the feasibility of JT-SOFI, quantum dots with different emission spectra were jointly labeled to the tubulin in COS7 cells, creating ultra-high density labeling. After analyzing and combining the fluorescence intermittency images emanating from spectrally resolved quantum dots, the microtubule networks are capable of being investigated with high fidelity and remarkably enhanced contrast at sub-diffraction resolution. The spectral separation also significantly decreased the frame number required for SOFI, enabling fast super-resolution microscopy through simultaneous data acquisition....

  4. Sensitivity Analysis of Fuel Centerline Temperatures in SuperCritical Water-cooled Reactors (SCWRs)

    Science.gov (United States)

    Abdalla, Ayman

    SuperCritical Water-cooled Reactors (SCWRs) are one of the six nuclear-reactor concepts currently being developed under the Generation-IV International Forum (GIF). A main advantage of SCW Nuclear Power Plants (NPPs) is that they offer higher thermal efficiencies compared to those of current conventional NPPs. Unlike today's conventional NPPs, which have thermal efficiencies between 30 - 35%, SCW NPPs will have thermal efficiencies within a range of 45 - 50%, owing to high operating temperatures and pressures (i.e., coolant temperatures as high as 625°C at 25 MPa pressure). The use of current fuel bundles with UO2 fuel at the high operating parameters of SCWRs may cause high fuel centerline temperatures, which could lead to fuel failure and fission gas release. Studies have shown that when the Variant-20 (43-element) fuel bundle was examined at SCW conditions, the fuel centerline temperature industry limit of 1850°C for UO2 and the sheath temperature design limit of 850°C might be exceeded. Therefore, new fuel-bundle designs, which comply with the design requirements, are required for future use in SCWRs. The main objective of this study to conduct a sensitivity analysis in order to identify the main factors that leads to fuel centerline temperature reduction. Therefore, a 54-element fuel bundle with smaller diameter of fuel elements compared to that of the 43-element bundle was designed and various nuclear fuels are examined for future use in a generic Pressure Tube (PT) SCWR. The 54-element bundle consists of 53 heated fuel elements with an outer diameter of 9.5 mm and one central unheated element of 20-mm outer diameter which contains burnable poison. The 54-element fuel bundle has an outer diameter of 103.45 mm, which is the same as the outer diameter of the 43-element fuel bundle. After developing the 54-element fuel bundle, one-dimensional heat-transfer analysis was conducted using MATLAB and NIST REFPROP programs. As a result, the Heat Transfer

  5. High-Sensitivity Magnetization Measurements

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The three most common instruments for high-sensitivity magnetization measurements (the vibrating-sample magnetometer, the alternating gradient magnetometer, and the SQUID magne tometer) are described and their limiting sensitivities are discussed. The advantages and disad vantages of each are described. Magnetometers using micro-machined force detectors are briefly mentioned.

  6. Fuel rod behavior under normal operating conditions in Super Fast Reactor with high power density

    Energy Technology Data Exchange (ETDEWEB)

    Ju, Haitao, E-mail: haitaoju@gmail.com [Science and Technology on Reactor System Design Technology Laboratory, Chengdu, Sichuan 610041 (China); Ishiwatari, Yuki [Department of Nuclear Engineering and Management, The University of Tokyo, Hongo, Bunkyo, Tokyo 113-8656 (Japan); Oka, Yoshiaki [Joint Department of Nuclear Energy, Waseda University, Totsukamachi, Shinjuku, Tokyo 169-8050 (Japan)

    2015-08-15

    Highlights: • The improved core of Super Fast Reactor with high power density is analyzed. • We analyzed four types of the limiting fuel rods. • The influence of Pu enrichment and compressive stress to yield strength ratio are analyzed. • The improved fuel rod design of the new core is suggested. - Abstract: A Super Fast Reactor is a pressure-vessel type, fast spectrum SuperCritical Water Reactor (SCWR) which is presently researched in a Japanese project. A preliminary core has an average power density of 158.8 W/cc. However one of the most important advantages of the Super Fast Reactor is the higher power density compared to the thermal spectrum SCWR, which reduces the capital cost. After the sensitivity analyses on the fuel rod configurations, the fuel assembly configurations and the core configurations, an improved core with an average power density of 294.8 W/cc is designed by 3-D neutronic/thermal-hydraulic coupled calculations. In order to ensure the fuel rod integrity of new core design with high power density, the fuel rod behaviors under normal operating condition are analyzed using fuel performance code FEMAXI-6. The power histories of each fuel rod are taken from the neutronics calculation results in the core design. The cladding surface temperature histories are generated from the thermal-hydraulic calculation results in the core design. Four types of the limiting fuel rods, individually with the Maximum Cladding Surface Temperature (MCST), Maximum Power Peak (MPP), Maximum Discharge Burnup (MDB) and Different Coolant Flow Pattern (DCFP), are chosen to cover all the fuel rods in the core. The available design range of the fuel rod design parameters, such as initial gas plenum pressure, gas plenum position, gas plenum length, grain size and gap size, are found out in order to satisfy the following design criteria: (1) Maximum fuel centerline temperature should be less than 1900 °C. (2) Maximum cladding stress in circumferential direction should

  7. Research Advances in High-Yielding Cultivation and Physiology of Super Rice

    Institute of Scientific and Technical Information of China (English)

    FU Jing; YANG Jian-chang

    2012-01-01

    In 1996,China launched a program to breed super rice or super hybrid rice by combining intersubspecific heterosis with ideal plant types.Today,approximately 80 super rice varieties have been released and some of them show high grain yields of 12-21 t/hm2 in field experiments.The main reasons for the high yields of super rice varieties,compared with those of conventional varieties,can be summarized as follows:more spikelets per panicle and larger sink size (number of spikelets per square meter); larger leaf area index,longer duration of green leaf,greater photosynthetic rate,higher lodging resistance,greater dry matter accumulation before the heading stage,greater remobilization of pre-stored carbohydrates from stems and leaves to grains during the grain-filling period; and larger root system and greater root activity.However,there are two main problems in super rice production:poor grain-filling of the later-flowering inferior spikelets (in contrast to earlier-flowering superior spikelets),and low and unstable seed-setting rate.Here,we review recent research advances in the crop physiology of super rice,focusing on biological features,formation of yield components,and population quality.Finally,we suggest further research on crop physiology of super rice.

  8. Inflammation-sensitive super enhancers form domains of coordinately regulated enhancer RNAs.

    Science.gov (United States)

    Hah, Nasun; Benner, Chris; Chong, Ling-Wa; Yu, Ruth T; Downes, Michael; Evans, Ronald M

    2015-01-20

    Enhancers are critical genomic elements that define cellular and functional identity through the spatial and temporal regulation of gene expression. Recent studies suggest that key genes regulating cell type-specific functions reside in enhancer-dense genomic regions (i.e., super enhancers, stretch enhancers). Here we report that enhancer RNAs (eRNAs) identified by global nuclear run-on sequencing are extensively transcribed within super enhancers and are dynamically regulated in response to cellular signaling. Using Toll-like receptor 4 (TLR4) signaling in macrophages as a model system, we find that transcription of super enhancer-associated eRNAs is dynamically induced at most of the key genes driving innate immunity and inflammation. Unexpectedly, genes repressed by TLR4 signaling are also associated with super enhancer domains and accompanied by massive repression of eRNA transcription. Furthermore, we find each super enhancer acts as a single regulatory unit within which eRNA and genic transcripts are coordinately regulated. The key regulatory activity of these domains is further supported by the finding that super enhancer-associated transcription factor binding is twice as likely to be conserved between human and mouse than typical enhancer sites. Our study suggests that transcriptional activities at super enhancers are critical components to understand the dynamic gene regulatory network.

  9. Second harmonic super-resolution microscopy for quantification of mRNA at single copy sensitivity.

    Science.gov (United States)

    Liu, Jing; Cho, Il-Hoon; Cui, Yi; Irudayaraj, Joseph

    2014-12-23

    Cell-specific information on the quantity and localization of key mRNAs at single copy sensitivity in single cells is critical for evaluating basic cellular process, disease risk, and efficacy of therapy. Quantification of overexpressed mRNAs beyond the diffraction limit is constrained by the optical property of the probes and microscopy techniques. In this report, nanosized barium titanium oxide (BaTiO3, BTO) crystals were utilized as probes for mRNA quantification by a second harmonic super-resolution microscopy (SHaSM). The SHaSM was able to detect a single copy of the human epidermal growth factor receptor 2 (Her2) mRNA at a resolution of 55.6 nm with the ability to resolve multiple mRNA copies in a diffraction-limited spot. Her2 mRNA per cell was counted in SK-BR-3, MCF-7, and HeLa cell lines as 595±79.1, 38.9±8.26, and 1.5±2.8, respectively. Our single-cell quantification results were validated with the fluorescence in situ hybridization studies and quantitative PCR, showing better specificity and selectivity over current single-molecule approaches for transcript detection. The SHaSM is expected to have an upper limit of resolving ∼10(4) transcripts in a single cell with the ability to monitor intracellular transcriptional dynamics at video rate. The developed approach has strong potential in clinical research and in the early diagnosis of life-threatening diseases such as cancer.

  10. SUPER-THIN COATING MATERIAL FOR HIGH-GRADE HIGHWAY

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The road surface of cement concrete in highway is easily cracked and even destroyed due to inhomogeneous subsiding of the road foundation. In this work, a super-thin-coating material is prepared in order to repair the destroyed thin road surface, in which polymers and steel-fibers are added into ordinary concrete to form a steel fiber reinforced polymer-cement-based composite. the composite was successfully used to repair road surface. Microstructure and mechanical properties of the composites are measured and analyzed.

  11. Fast super-resolution imaging with ultra-high labeling density achieved by joint tagging super-resolution optical fluctuation imaging.

    Science.gov (United States)

    Zeng, Zhiping; Chen, Xuanze; Wang, Hening; Huang, Ning; Shan, Chunyan; Zhang, Hao; Teng, Junlin; Xi, Peng

    2015-02-10

    Previous stochastic localization-based super-resolution techniques are largely limited by the labeling density and the fidelity to the morphology of specimen. We report on an optical super-resolution imaging scheme implementing joint tagging using multiple fluorescent blinking dyes associated with super-resolution optical fluctuation imaging (JT-SOFI), achieving ultra-high labeling density super-resolution imaging. To demonstrate the feasibility of JT-SOFI, quantum dots with different emission spectra were jointly labeled to the tubulin in COS7 cells, creating ultra-high density labeling. After analyzing and combining the fluorescence intermittency images emanating from spectrally resolved quantum dots, the microtubule networks are capable of being investigated with high fidelity and remarkably enhanced contrast at sub-diffraction resolution. The spectral separation also significantly decreased the frame number required for SOFI, enabling fast super-resolution microscopy through simultaneous data acquisition. As the joint-tagging scheme can decrease the labeling density in each spectral channel, thereby bring it closer to single-molecule state, we can faithfully reconstruct the continuous microtubule structure with high resolution through collection of only 100 frames per channel. The improved continuity of the microtubule structure is quantitatively validated with image skeletonization, thus demonstrating the advantage of JT-SOFI over other localization-based super-resolution methods.

  12. Fast Super-Resolution Imaging with Ultra-High Labeling Density Achieved by Joint Tagging Super-Resolution Optical Fluctuation Imaging

    Science.gov (United States)

    Zeng, Zhiping; Chen, Xuanze; Wang, Hening; Huang, Ning; Shan, Chunyan; Zhang, Hao; Teng, Junlin; Xi, Peng

    2015-01-01

    Previous stochastic localization-based super-resolution techniques are largely limited by the labeling density and the fidelity to the morphology of specimen. We report on an optical super-resolution imaging scheme implementing joint tagging using multiple fluorescent blinking dyes associated with super-resolution optical fluctuation imaging (JT-SOFI), achieving ultra-high labeling density super-resolution imaging. To demonstrate the feasibility of JT-SOFI, quantum dots with different emission spectra were jointly labeled to the tubulin in COS7 cells, creating ultra-high density labeling. After analyzing and combining the fluorescence intermittency images emanating from spectrally resolved quantum dots, the microtubule networks are capable of being investigated with high fidelity and remarkably enhanced contrast at sub-diffraction resolution. The spectral separation also significantly decreased the frame number required for SOFI, enabling fast super-resolution microscopy through simultaneous data acquisition. As the joint-tagging scheme can decrease the labeling density in each spectral channel, thereby bring it closer to single-molecule state, we can faithfully reconstruct the continuous microtubule structure with high resolution through collection of only 100 frames per channel. The improved continuity of the microtubule structure is quantitatively validated with image skeletonization, thus demonstrating the advantage of JT-SOFI over other localization-based super-resolution methods. PMID:25665878

  13. Development of High Level Trigger Software for Belle II at SuperKEKB

    Science.gov (United States)

    Lee, S.; Itoh, R.; Katayama, N.; Mineo, S.

    2011-12-01

    The Belle collaboration has been trying for 10 years to reveal the mystery of the current matter-dominated universe. However, much more statistics is required to search for New Physics through quantum loops in decays of B mesons. In order to increase the experimental sensitivity, the next generation B-factory, SuperKEKB, is planned. The design luminosity of SuperKEKB is 8 x 1035cm-2s-1 a factor 40 above KEKB's peak luminosity. At this high luminosity, the level 1 trigger of the Belle II experiment will stream events of 300 kB size at a 30 kHz rate. To reduce the data flow to a manageable level, a high-level trigger (HLT) is needed, which will be implemented using the full offline reconstruction on a large scale PC farm. There, physics level event selection is performed, reducing the event rate by ~ 10 to a few kHz. To execute the reconstruction the HLT uses the offline event processing framework basf2, which has parallel processing capabilities used for multi-core processing and PC clusters. The event data handling in the HLT is totally object oriented utilizing ROOT I/O with a new method of object passing over the UNIX socket connection. Also under consideration is the use of the HLT output as well to reduce the pixel detector event size by only saving hits associated with a track, resulting in an additional data reduction of ~ 100 for the pixel detector. In this contribution, the design and implementation of the Belle II HLT are presented together with a report of preliminary testing results.

  14. High resolution imaging in cross-section of a metal-oxide-semiconductor field-effect-transistor using super-higher-order nonlinear dielectric microscopy

    Science.gov (United States)

    Chinone, N.; Yamasue, K.; Honda, K.; Cho, Y.

    2013-11-01

    Scanning nonlinear dielectric microscopy (SNDM) can evaluate carrier or charge distribution in semiconductor devices. High sensitivity to capacitance variation enables SNDM to measure the super-high-order (higher than 3rd) derivative of local capacitance-voltage (C-V) characteristics directly under the tip (dnC/dVn,n = 3, 4, ...). We demonstrate improvement of carrier density resolution by measurement of dnC/dVn,n = 1, 2, 3, 4 (super-higher-order method) in the cross-sectional observation of metal-oxide-semiconductor field-effect-transistor.

  15. SuperCDMS SNOLAB Low-Mass Detectors: Ultra-Sensitive Phonon Calorimeters for a Sub-GeV Dark Matter Search

    CERN Document Server

    Kurinsky, Noah; Partridge, Richard; Cabrera, Blas; Pyle, Matt

    2016-01-01

    We present the technical design for the SuperCDMS high-voltage, low-mass dark matter detectors, designed to be sensitive to dark matter down to 300 MeV/$c^2$ in mass and resolve individual electron-hole pairs from low-energy scattering events in high-purity Ge and Si crystals. In this paper we discuss some of the studies and technological improvements which have allowed us to design such a sensitive detector, including advances in phonon sensor design and detector simulation. With this design we expect to achieve better than 10 eV (5 eV) phonon energy resolution in our Ge (Si) detectors, and recoil energy resolution below 1eV by exploiting Luke-Neganov phonon generation of charges accelerated in high fields.

  16. The effect of water stress on super-high- density 'Koroneiki' olive oil quality.

    Science.gov (United States)

    Dag, Arnon; Naor, Amos; Ben-Gal, Alon; Harlev, Guy; Zipori, Isaac; Schneider, Doron; Birger, Reuven; Peres, Moti; Gal, Yoni; Kerem, Zohar

    2015-08-15

    Over the last two decades, the area of cultivated super-high-density olive orchards has increased rapidly. Water stress is an important tool in super-high-density orchards to reduce tree growth and promote suitability for overhead mechanical harvesters. Little is known regarding the effect of water stress in super-high-density orchards on oil quality parameters. In this study the effect of irrigation rate on oil quality parameters was evaluated in a six-year-old super-high-density 'Koreneiki' olive orchard for five consecutive seasons. Five water status levels, determined by irrigating in order to maintain various midday stem water potential threshold values (-1.5, -2, -2.5, -3 and -4 MPa), were applied during the oil accumulation stage. The MUFA/PUFA ratio and free fatty acid content generally decreased as a function of increasing tree water stress. In most seasons a reduction in polyphenols was found with decreasing irrigation level. Peroxide value was not affected by the water stress level. The present study demonstrates that limiting irrigation and exposure of olive trees to water stress in a super-high-density orchard lowers free fatty acid content and therefore benefits oil quality. However, the decreased MUFA/PUFA ratio and the reduction in polyphenol content that were also found under increased water stress negatively influence oil quality. © 2014 Society of Chemical Industry.

  17. Practice and Thought on Developing Hybrid Rice for Super High Yield by Exploiting Inter-subspecific Heterosis

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    Since the breakthrough of grain yield owing to the development of dwarf rice and three-line system hybrid rice, rice breeding for high yield hardly had showed significant progress in the next successive two decades. It was considered that utilizing heterosis between subspecific varieties (Oryza sativa L.) would be an effective approach to increase yield further. During 1987-1993,an indica-japonica hybrid Yayou 2 yielded as high as 10.5 t/ha; however, it failed to be commercialized because of seed purity problem due to non-uniform emasculation by chemical agent in seed production, and sensitivity of seed setting in F1 plants to environmental conditions. In the past decade, two inter-subspeific hybrids, Liangyoupeijiu (Peiai 64S/9311, javanica/indica) and Liangyou E32 (Peiai 64S/E32, javanica/japonica); both of them exhibited grain yield higher than 10.5 t/ha, and were widely judged as the pioneers of super hybrid rice. Liangyoupeijiu has been successfully popularized over 4 million hectare in wide climatic areas, while Liangyou E32 made a yield record and offered a model of plant ideotype for super hybrid rice. It was considered that in combination with plant ideotype, active physiological functions, and wide-range adaptability to ecological conditions, exploitation of indica-japonica heterosis would be the key approach for super hybrid rice breeding.

  18. Super-resonant radiation stimulated by high-harmonics

    CERN Document Server

    Loures, Cristian Redondo; Faccio, Daniele; Biancalana, Fabio

    2016-01-01

    Solitons propagating in media with higher order dispersion will shed radiation known as dispersive wave or resonant radiation, with applications in frequency broadening, deep UV sources for spectroscopy or simply fundamental studies of soliton physics. Starting from a recently proposed equation that models the behaviour of ultrashort optical pulses in nonlinear materials using the analytic signal, we find that the resonant radiation associated with the third-harmonic generation term of the equation is parametrically stimulated with an unprecedented gain. Resonant radiation levels, typically only a small fraction of the soliton, are now as intense as the soliton itself. The mechanism is quite universal and works also in normal dispersion and with harmonics higher than the third. We report experimental hints of this super-resonant radiation stimulated by the fifth harmonic in diamond.

  19. High Resolution Bathymetry Estimation Improvement with Single ImageSuper Resolution Algorithm Super Resolution Forests

    Science.gov (United States)

    2017-01-26

    process of the SRF algorithm, we were able to further increase the mean PSNR score of the high resolution estimated data from previously used bicubic...This meant that implementing the edited variance before the bicubic estimates were created caused the mean PSNR to increase the most, and all...interpolation (by about 1 dB). Figure 7: PSNR comparison (with mean scores) between Bicubic Interpolation and SRF Figure 7 shows the comparison between

  20. Astronomy. ASASSN-15lh: A highly super-luminous supernova.

    Science.gov (United States)

    Dong, Subo; Shappee, B J; Prieto, J L; Jha, S W; Stanek, K Z; Holoien, T W-S; Kochanek, C S; Thompson, T A; Morrell, N; Thompson, I B; Basu, U; Beacom, J F; Bersier, D; Brimacombe, J; Brown, J S; Bufano, F; Chen, Ping; Conseil, E; Danilet, A B; Falco, E; Grupe, D; Kiyota, S; Masi, G; Nicholls, B; Olivares E, F; Pignata, G; Pojmanski, G; Simonian, G V; Szczygiel, D M; Woźniak, P R

    2016-01-15

    We report the discovery of ASASSN-15lh (SN 2015L), which we interpret as the most luminous supernova yet found. At redshift z = 0.2326, ASASSN-15lh reached an absolute magnitude of Mu ,AB = -23.5 ± 0.1 and bolometric luminosity Lbol = (2.2 ± 0.2) × 10(45) ergs s(-1), which is more than twice as luminous as any previously known supernova. It has several major features characteristic of the hydrogen-poor super-luminous supernovae (SLSNe-I), whose energy sources and progenitors are currently poorly understood. In contrast to most previously known SLSNe-I that reside in star-forming dwarf galaxies, ASASSN-15lh appears to be hosted by a luminous galaxy (MK ≈ -25.5) with little star formation. In the 4 months since first detection, ASASSN-15lh radiated (1.1 ± 0.2) × 10(52) ergs, challenging the magnetar model for its engine. Copyright © 2016, American Association for the Advancement of Science.

  1. Highly super-Chandrasekhar white dwarfs in an extensive GRMHD framework

    CERN Document Server

    Das, Upasana

    2016-01-01

    Our consistent effort to unravel the mystery of super-Chandrasekhar white dwarfs (WDs), by exploiting the potential of magnetic fields, has brought this topic considerable attention. This is also evident from the recent surge in the corresponding literature. In the present work, by means of full-scale general relativistic magnetohydrodynamic (GRMHD) numerical analysis, we confirm the existence of stable, highly magnetized, significantly super-Chandrasekhar WDs having mass exceeding 3 solar mass. We have explored various possible field configurations, namely, poloidal, toroidal and mixed, by self-consistently incorporating the departure from spherical symmetry induced by a strong magnetic field. Such super-Chandrasekhar WDs can be ideal progenitors of peculiar, over-luminous type Ia supernovae.

  2. Simulation and Experimental Analysis of Super High-Speed Grinding of Ductile Material

    Institute of Scientific and Technical Information of China (English)

    SHIMIZU; Jun; EDA; Hiroshi

    2002-01-01

    This study aims to reduce the work-affected layer of the machined surface by carrying out the grinding at the speed over static pr o pagation speed of plastic wave of ductile materials and also aims to clarify suc h super high-speed machining mechanism.This paper reports on the result obtain ed through the molecular dynamics simulations and experiments on the super-spee d grinding below and beyond static propagation speed of aluminum.From the simul ation results,it is verified that the plastic deformation ...

  3. High Resolution Pulse Compression Imaging Using Super Resolution FM-Chirp Correlation Method (SCM)

    Science.gov (United States)

    Fujiwara, M.; Okubo, K.; Tagawa, N.

    This study addresses the issue of the super-resolution pulse compression technique (PCT) for ultrasound imaging. Time resolution of multiple ultrasonic echoes using the FM-Chirp PCT is limited by the bandwidth of the sweep-frequency. That is, the resolution depends on the sharpness of auto-correlation function. We propose the Super resolution FM-Chirp correlation Method (SCM) and evaluate its performance. This method is based on the multiple signal classification (MUSIC) algorithm. Our simulations were made for the model assuming multiple signals reflected from some scatterers. We confirmed that SCM detects time delay of complicated reflected signals successfully with high resolution.

  4. Movable thin films with embedded high-index microspheres for super-resolution microscopy

    CERN Document Server

    Allen, Kenneth W; Li, Yangcheng; Limberopoulos, Nicholaos I; Walker, Dennis E; Urbas, Augustine M; Liberman, Vladimir; Astratov, Vasily N

    2015-01-01

    Microsphere-assisted imaging emerged as a surprisingly simple way of achieving optical super-resolution imaging. In this work, we use movable PDMS thin films with embedded high-index barium titanate glass microspheres a sample scanning capability was developed, thus removing the main limitation of this technology based on its small field-of-view.

  5. High resolution FISH on super-stretched flow-sorted plant chromosomes.

    NARCIS (Netherlands)

    Valárik, M.; Bartos, J.; Kovarova, P.; Kubalakova, M.; Jong, de J.H.S.G.M.; Dolezel, J.

    2004-01-01

    A novel high-resolution fluorescence in situ hybridisation (FISH) strategy, using super-stretched flow-sorted plant chromosomes as targets, is described. The technique that allows longitudinal extension of chromosomes of more than 100 times their original metaphase size is especially attractive for

  6. High-resolution and super stacking of time-reversal mirrors in locating seismic sources

    KAUST Repository

    Cao, Weiping

    2011-07-08

    Time reversal mirrors can be used to backpropagate and refocus incident wavefields to their actual source location, with the subsequent benefits of imaging with high-resolution and super-stacking properties. These benefits of time reversal mirrors have been previously verified with computer simulations and laboratory experiments but not with exploration-scale seismic data. We now demonstrate the high-resolution and the super-stacking properties in locating seismic sources with field seismic data that include multiple scattering. Tests on both synthetic data and field data show that a time reversal mirror has the potential to exceed the Rayleigh resolution limit by factors of 4 or more. Results also show that a time reversal mirror has a significant resilience to strong Gaussian noise and that accurate imaging of source locations from passive seismic data can be accomplished with traces having signal-to-noise ratios as low as 0.001. Synthetic tests also demonstrate that time reversal mirrors can sometimes enhance the signal by a factor proportional to the square root of the product of the number of traces, denoted as N and the number of events in the traces. This enhancement property is denoted as super-stacking and greatly exceeds the classical signal-to-noise enhancement factor of. High-resolution and super-stacking are properties also enjoyed by seismic interferometry and reverse-time migration with the exact velocity model. © 2011 European Association of Geoscientists & Engineers.

  7. Development of a New Foxtail Millet Germplasm with Super Early Maturity and High Iron Content

    Institute of Scientific and Technical Information of China (English)

    LIU Zheng-li; SUN Shi-xian; CHENG Ru-hong; HUANG Wen-sheng; LIU Jun-xin; QU Zhu-feng; XIA Xue-yan; SHI Zhi-gang

    2006-01-01

    Super Early Maturation No.2 is a new foxtail millet germplasm developed by using the targeted-character-gene-bankbreeding method. It has several outstanding characteristics. (1) Super early maturity. It can normally mature in Bashang,Hebei Province, China, where the altitude is around 1 400 meters, and it needs 1 650℃ of effective accumulated temperature in the growing period. (2) Millet is rich in iron. The iron content of the millet of Super Early Maturation No.2 is 54.10 mg kg-1,which is 62.0% higher than the average iron content of the foxtail millet varieties in China. (3) High crude fat content. Its crude fat content is 6.24%, which is 54.1% higher than the average content of foxtail millet varieties in China. (4) High crude protein content. The average of the crude protein content of all the foxtail millet varieties in China is 12.71%, only5% varieties surpass 14%, however, the crude protein content of Super Early Maturation No.2 is 14.36%, which is rare in improved varieties of foxtail millet in China. (5) Overall characteristics are good.

  8. Growth and development characteristics of super-high-yielding mid-season japonica rice

    Institute of Scientific and Technical Information of China (English)

    YANG Jianchang; DU Yong; WU Changfu; LIU Lijun; WANG Zhiqin; ZHU Qingsen

    2007-01-01

    Rice is one of the most important food crops in China.The realization of the super-high-yielding (SHY)type has great significance in ensuring food security in this country.This study investigated the growth and development characteristics of the super-high-yielding rice (grain yield>11 t/hm2).Four mid-season japonica rice cultivars (including lines):Lianjiajing 2,Huajing 5,0026 and 9823,were grown in the paddy field.Growth analysis was performed during the growth period,and yield components were determined at maturity.Results showed that SHY rice had more sipkelets per panicle and higher filled-grain percentage than the high-yielding rice (CK,grain yield 8.98-9.16 t/hm2).There was no significant difference in the 1 000-grain weight between the super-high-yielding and the CK.Super-high-yield rice exhib ited fewer tillers at the early growth stage (from transplanting to jointing),with a higher ratio of productive tillers to total tillers,when compared with the CK.The leaf area index (LAI),photosynthetic potential and dry matter accumulation were lower for the SHY rice than those for the CK at the early growth stage,and the differences were not significant between the two rice types at heading,but were greater in the former than the latter after heading.The root-shoot ratio at each growth stage,root bleedings from heading to maturity,grain-leaf ratio,translocation percentage of the matter from stems and sheaths and harvest index of super-high-yielding rice were greater than those of CK.The indexes for the growth and development of SHY mid-season rice population were suggested,i.e.total spikelets>4.5×104/m2,filled-grain percentage>90%,1 000-grain weight>26 g;ratio of productive tillers>80%,leaf area index at heading 7.5-8.0,photosynthetic potential during the whole growth period >22 t/hm2,harvest index>0.51;grain-leaf ratio (number of spikelets per cm2 leaf area)>0.58;root-shoot ratio at heading tion approaches and key cultivation techniques for raising the

  9. Discussion on Super High-temperature Weather and City Construction

    Institute of Scientific and Technical Information of China (English)

    OuYang Shoucheng; Wei Ming

    2006-01-01

    With the method of structure analysis, this work analyzes the real data of the high-temperature weather of China in 2003 and those in history, and finds out that the structure character of the hightemperature weather process corresponds to the distribution of urban buildings. The result shows that excessive dense buildings could influence the atmosphere structure, which leads to the urban temperature increasing sharply. On the other hand, the structure analysis also reveals some problems on urban construction, and the corresponding countermeasure is an efficient method for high-temperature weather forecast.

  10. High sensitivity RNA pseudoknot prediction

    OpenAIRE

    Huang, Xiaolu; Ali, Hesham

    2006-01-01

    Most ab initio pseudoknot predicting methods provide very few folding scenarios for a given RNA sequence and have low sensitivities. RNA researchers, in many cases, would rather sacrifice the specificity for a much higher sensitivity for pseudoknot detection. In this study, we introduce the Pseudoknot Local Motif Model and Dynamic Partner Sequence Stacking (PLMM_DPSS) algorithm which predicts all PLM model pseudoknots within an RNA sequence in a neighboring-region-interference-free fashion. T...

  11. SuperTIGER-2: A Very-Large-Area, High-Resolution Trans-Iron Cosmic Ray Investigation

    Science.gov (United States)

    Binns, Walter

    This is the lead proposal of a multi-institution proposal for the investigation titled “SuperTIGER-2: A Very-Large-Area, High Resolution Trans-Iron Cosmic Ray Investigation”. SuperTIGER is a very-large-area instrument for measuring the composition of galactic cosmic rays on high-altitude balloon flights over Antarctica. SuperTIGER-1 had a highly successful 55-day flight in 2012/2013. The data quality is excellent, enabling us to clearly resolve all nuclei from Z=10 to Z=40. Additionally, although statistics are low, there appears to be clear resolution of elements in the Z=40- 60 range. The excellent data from this flight will enable us to achieve the initial goals of the program. The high performance of the instrument, both in charge resolution and collecting power, and the science that can be addressed by measurements of nuclei heavier than Z=40, makes a compelling case to conduct additional flights to measure the abundances of individual nuclei up to Z=60. This is a 4-year proposal with the primary objective of measuring the abundances of individual nuclei with 41#Z#60 and to substantially increase the number of 30#Z#40 nuclei measured. This will be the first time that individual elemental abundances for the 41#Z#60 range will be obtained. These new measurements will provide sensitive tests and clarification of the OB-association model of galactic cosmic-ray origins and will test models for atomic processes by which nuclei are selected for acceleration to cosmic-ray energies. They will enable us to determine if the enrichment of refractory elements (those that exist primarily in dust grains in the interstellar medium) over volatile elements (those that exist primarily in the gas phase) extends into the Z=41-60 charge range. They will also enable us to unambiguously determine the extent of any r-process enrichment. SuperTIGER provides critical measurements to unravel the mystery of galactic cosmic ray (GCR) origins and complements instruments with different

  12. Super soft silicone elastomers with high dielectric permittivity

    DEFF Research Database (Denmark)

    Madsen, Frederikke Bahrt; Yu, Liyun; Hvilsted, Søren;

    2015-01-01

    Dielectric elastomers (DEs) have many favourable properties. The obstacle of high driving voltages, however, limits the commercial viability of the technology at present. Driving voltage can be lowered by decreasing the Young’s modulus and increasing the dielectric permittivity of silicone elasto...

  13. High Spin Isomers and Super Heavy Elements (SHE) Synthesis

    Science.gov (United States)

    Popescu, Domitian G.

    2010-04-01

    To get closer to the SHE-Island the new radioactive beams are proposed for future fusion reaction. We suggest something different : to use the advantage of High Spin Isomer States, by tacking into account the importance of the G (spin-isospin cupling) suggested by Ripka 1.

  14. Super-Resolution Reconstruction of High-Resolution Satellite ZY-3 TLC Images.

    Science.gov (United States)

    Li, Lin; Wang, Wei; Luo, Heng; Ying, Shen

    2017-05-07

    Super-resolution (SR) image reconstruction is a technique used to recover a high-resolution image using the cumulative information provided by several low-resolution images. With the help of SR techniques, satellite remotely sensed images can be combined to achieve a higher-resolution image, which is especially useful for a two- or three-line camera satellite, e.g., the ZY-3 high-resolution Three Line Camera (TLC) satellite. In this paper, we introduce the application of the SR reconstruction method, including motion estimation and the robust super-resolution technique, to ZY-3 TLC images. The results show that SR reconstruction can significantly improve both the resolution and image quality of ZY-3 TLC images.

  15. Super-High Resolution Time Interval Measurement Method Based on Time-Space Relationships

    Institute of Scientific and Technical Information of China (English)

    DU Bao-Qiang; ZHOU Wei

    2009-01-01

    Based on the principle of quantized delay-time, a super-high resolution time interval measurement method is proposed based on time-space relationships.Using the delay-time stability that time and frequency signal travel in a specific medium, the measured time interval can be quantized.Combined with the phase coincidence detection technique, the measurement of time can be changed into the measurement of space length.The resolution and the stability of the measurement system are easily improved.Experimental results show that the measurement resolution of the measured time interval depends on the length difference of the double delay-time unit.When the length difference is set up on millimeter level or sub-millimeter level, super-high measurement resolution from hundreds of picosecond to tens of picosecond can be obtained.

  16. High contrast imaging of exoplanets on ELTs using a super-Nyquist wavefront control scheme

    CERN Document Server

    Gerard, Benjamin L

    2016-01-01

    One of the key science goals for extremely large telescopes (ELTs) is the detailed characterization of already known directly imaged exoplanets. The typical adaptive optics (AO) Nyquist control region for ELTs is ~0.4 arcseconds, placing many already known directly imaged planets outside the DM control region and not allowing any standard wavefront control scheme to remove speckles that would allow higher SNR images/spectra to be acquired. This can be fixed with super-Nyquist wavefront control (SNWFC), using a sine wave phase plate to allow for wavefront control outside the central DM Nyquist region. We demonstrate that SNWFC is feasible through a simple, deterministic, non-coronagraphic, super-Nyquist speckle nulling technique in the adaptive optics laboratory at the National Research Council of Canada. We also present results in simulation of how SNWFC using the self coherent camera (SCC) can be used for high contrast imaging. This technique could be implemented on future high contrast imaging instruments t...

  17. SOWFA Super-Controller: A High-Fidelity Tool for Evaluating Wind Plant Control Approaches

    Energy Technology Data Exchange (ETDEWEB)

    Fleming, P.; Gebraad, P.; van Wingerden, J. W.; Lee, S.; Churchfield, M.; Scholbrock, A.; Michalakes, J.; Johnson, K.; Moriarty, P.

    2013-01-01

    This paper presents a new tool for testing wind plant controllers in the Simulator for Offshore Wind Farm Applications (SOWFA). SOWFA is a high-fidelity simulator for the interaction between wind turbine dynamics and the fluid flow in a wind plant. The new super-controller testing environment in SOWFA allows for the implementation of the majority of the wind plant control strategies proposed in the literature.

  18. Second Approximation Model for Optical Head in Super High Density Storage Technology

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    The paper presents second approximation model for optical head in super high-density storage technology firstly and it is an important part for three grades approximate model of ultra-small-size quantum well corn-shaped laser and simulative calculations. It supplies the important and useful results for the NFOD optical head design with ultra thin active layer and ultra small spot laser.

  19. Development of a Parching Machine Using Super-Heated Vapor or Super-Heated High-Moisture Atmosphere

    Science.gov (United States)

    Sato, Shoichi; Shinsho, Seiji; Iriki, Hiroyuki; Asai, Junya; Suganuma, Hirofumi; Shibata, Tsutomu

    We developed a new parching machine with super-heated vapor or super-heated highmoisture atmosphere as a heat medium, and investigated the influence exerted on the characteristics of manufactured tea and crude tea quality. (1)We developed machine specifications that improved throughput and allowed us to control stable quality compared with the conventional kamairicha parching machine. (2)The new parching machine could not only manufacture like kamairicha but also achieve various degrees of steaming of products like green tea or heavily steamed sencha. (3)The new parching machine could not only deactivate enzymes but dry leaves. (4)The influence of throughput was great with respect to the grade of pan-parched flavour, which meant that there was a contact opportunity for tea leaves and the surface of machine's wall. (5)Unpleasant smells such as that produced in a summer crop of tea were reduced by the new parching machine.

  20. High sensitivity RNA pseudoknot prediction.

    Science.gov (United States)

    Huang, Xiaolu; Ali, Hesham

    2007-01-01

    Most ab initio pseudoknot predicting methods provide very few folding scenarios for a given RNA sequence and have low sensitivities. RNA researchers, in many cases, would rather sacrifice the specificity for a much higher sensitivity for pseudoknot detection. In this study, we introduce the Pseudoknot Local Motif Model and Dynamic Partner Sequence Stacking (PLMM_DPSS) algorithm which predicts all PLM model pseudoknots within an RNA sequence in a neighboring-region-interference-free fashion. The PLM model is derived from the existing Pseudobase entries. The innovative DPSS approach calculates the optimally lowest stacking energy between two partner sequences. Combined with the Mfold, PLMM_DPSS can also be used in predicting complicated pseudoknots. The test results of PLMM_DPSS, PKNOTS, iterated loop matching, pknotsRG and HotKnots with Pseudobase sequences have shown that PLMM_DPSS is the most sensitive among the five methods. PLMM_DPSS also provides manageable pseudoknot folding scenarios for further structure determination.

  1. Variable-intercept panel model for deformation zoning of a super-high arch dam.

    Science.gov (United States)

    Shi, Zhongwen; Gu, Chongshi; Qin, Dong

    2016-01-01

    This study determines dam deformation similarity indexes based on an analysis of deformation zoning features and panel data clustering theory, with comprehensive consideration to the actual deformation law of super-high arch dams and the spatial-temporal features of dam deformation. Measurement methods of these indexes are studied. Based on the established deformation similarity criteria, the principle used to determine the number of dam deformation zones is constructed through entropy weight method. This study proposes the deformation zoning method for super-high arch dams and the implementation steps, analyzes the effect of special influencing factors of different dam zones on the deformation, introduces dummy variables that represent the special effect of dam deformation, and establishes a variable-intercept panel model for deformation zoning of super-high arch dams. Based on different patterns of the special effect in the variable-intercept panel model, two panel analysis models were established to monitor fixed and random effects of dam deformation. Hausman test method of model selection and model effectiveness assessment method are discussed. Finally, the effectiveness of established models is verified through a case study.

  2. Proteomic Analysis of the Response of Liangyoupeijiu (Super High-Yield Hybrid Rice) Seedlings to Cold Stress

    Institute of Scientific and Technical Information of China (English)

    Ping-Fang Yang; Xiao-Juan Li; Yu Liang; Yu-Xiang Jing; Shi-Hua Shen; Ting-Yun Kuang

    2006-01-01

    Liangyoupeijiu is a super high-yield hybrid rice. Despite its advantages with respect to yield and grain quality, it is sensitive to cold, which keeps it from being widely cultivated. We subjected Liangyoupeijiu seedlings to 4 ℃ cold treatment, then extracted the leaf proteins. After 2-D gel electrophoresis separation and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry analysis, a series of differentially displayed proteins were identified. Some metabolism-associated proteins were found among the downregulated proteins, such as carbamoyl phosphate synthetase, transketolase 1, dihydrolipoamide dehydrogenase and glyceraldehyde 3-phosphate dehydrogenase. The upregulated proteins included both stress-resistance proteins such as nucleoside diphosphate kinase Ⅰ and proteins that are negative for rice growth, such as FtsH-like protein, plastid fusion and/or translocation factor (Pftf) and actin. Our results indicate that cold may inhibit Liangyoupeijiu growth through decreasing metabolic activity and damaging cell structure.

  3. Sensitivity of summer ensembles of super-parameterized US mesoscale convective systems to cloud resolving model microphysics and resolution

    Science.gov (United States)

    Elliott, E.; Yu, S.; Kooperman, G. J.; Morrison, H.; Wang, M.; Pritchard, M. S.

    2014-12-01

    Microphysical and resolution sensitivities of explicitly resolved convection within mesoscale convective systems (MCSs) in the central United States are well documented in the context of single case studies simulated by cloud resolving models (CRMs) under tight boundary and initial condition constraints. While such an experimental design allows researchers to causatively isolate the effects of CRM microphysical and resolution parameterizations on modeled MCSs, it is still challenging to produce conclusions generalizable to multiple storms. The uncertainty associated with the results of such experiments comes both from the necessary physical constraints imposed by the limited CRM domain as well as the inability to evaluate or control model internal variability. A computationally practical method to minimize these uncertainties is the use of super-parameterized (SP) global climate models (GCMs), in which CRMs are embedded within GCMs to allow their free interaction with one another as orchestrated by large-scale global dynamics. This study uses NCAR's SP Community Atmosphere Model 5 (SP-CAM5) to evaluate microphysical and horizontal resolution sensitivities in summer ensembles of nocturnal MCSs in the central United States. Storm events within each run were identified using an objective empirical orthogonal function (EOF) algorithm, then further calibrated to harmonize individual storm signals and account for the temporal and spatial heterogeneity between them. Three summers of control data from a baseline simulation are used to assess model internal interannual variability to measure its magnitude relative to sensitivities in a number of distinct experimental runs with varying CRM parameters. Results comparing sensitivities of convective intensity to changes in fall speed assumptions about dense rimed species, one- vs. two-moment microphysics, and CRM horizontal resolution will be discussed.

  4. Highly selective creation of hydrophilic micro-craters on super hydrophobic surface using electrohydrodynamic jet printing

    Science.gov (United States)

    Lee, Jaehyun; Hwang, Sangyeon; Prasetyo, Fariza Dian; Nguyen, Vu Dat; Hong, Jungwoo; Shin, Jennifer H.; Byun, Doyoung

    2014-11-01

    Selective surface modification is considered as an alternative to conventional printing techniques in high resolution patterning. Here, we present fabrication of hydrophilic patterns on the super hydrophobic surface, which makes structure on the hydrophilic region. The super hydrophobic surface is able to be chemically changed to hydrophilic with alcohols. As a consecutive process, electrohydrodynamic (EHD) jet printing was utilized to fabricate local hydrophilic craters with 30-200 μm sizes. 3 kinds of target liquids were deposited well on hydrophilic region; PEDOT (poly 3,4 ethylenediocythiophene), polystyrene nano-particles, and salmonella bacteria medium. Additionally, qualitative analysis were presented for modification mechanism and surface properties on super hydrophobic/hydrophilic by analysis of surface energy with contact angle, SEM (scanning electron microscopy) image, and SIMS (secondary ion mass spectroscopy) analysis. This new simple modification method provides possibility to be utilizing in bio-patterning engineering such as cell culturing microchip and lab on a chip. This research was supported by the Basi Science Research Program through the National Research Foundation of Korea (NRF) (Grand Number: 2014-023284).

  5. High sensitivity radon emanation measurements.

    Science.gov (United States)

    Zuzel, G; Simgen, H

    2009-05-01

    The presented radon detection technique employs miniaturized ultra-low background proportional counters. (222)Rn samples are purified, mixed with a counting gas and filled into a counter using a special glass vacuum line. The absolute sensitivity of the system is estimated to be 40 microBq (20 (222)Rn atoms). For emanation investigations two metal sealed stainless steel vessels and several glass vials are available. Taking into account their blank contributions, measurements at a minimum detectable activity of about 100 microBq can be performed.

  6. Cryogenic High-Sensitivity Magnetometer

    Science.gov (United States)

    Day, Peter; Chui, Talso; Goodstein, David

    2005-01-01

    A proposed magnetometer for use in a cryogenic environment would be sensitive enough to measure a magnetic-flux density as small as a picogauss (10(exp -16) Tesla). In contrast, a typical conventional flux-gate magnetometer cannot measure a magnetic-flux density smaller that about 1 microgauss (10(exp -10) Tesla). One version of this device, for operation near the low end of the cryogenic temperature range, would include a piece of a paramagnetic material on a platform, the temperature of which would be controlled with a periodic variation. The variation in temperature would be measured by use of a conventional germanium resistance thermometer. A superconducting coil would be wound around the paramagnetic material and coupled to a superconducting quantum interference device (SQUID) magnetometer.

  7. On the High Temperature Deformation Behaviour of 2507 Super Duplex Stainless Steel

    Science.gov (United States)

    Mishra, M. K.; Balasundar, I.; Rao, A. G.; Kashyap, B. P.; Prabhu, N.

    2017-01-01

    High temperature deformation behaviour of 2507 super duplex stainless steel was investigated by conducting isothermal hot compression tests. The dominant restoration processes in ferrite and austenite phases present in the material were found to be distinct. The possible causes for these differences are discussed. Based on the dynamic materials model, processing map was developed to identify the optimum processing parameters. The microstructural mechanisms operating in the material were identified. A unified strain-compensated constitutive equation was established to describe the high temperature deformation behaviour of the material under the identified processing conditions. Standard statistical parameter such as correlation coefficient has been used to validate the established equation.

  8. On the High Temperature Deformation Behaviour of 2507 Super Duplex Stainless Steel

    Science.gov (United States)

    Mishra, M. K.; Balasundar, I.; Rao, A. G.; Kashyap, B. P.; Prabhu, N.

    2017-02-01

    High temperature deformation behaviour of 2507 super duplex stainless steel was investigated by conducting isothermal hot compression tests. The dominant restoration processes in ferrite and austenite phases present in the material were found to be distinct. The possible causes for these differences are discussed. Based on the dynamic materials model, processing map was developed to identify the optimum processing parameters. The microstructural mechanisms operating in the material were identified. A unified strain-compensated constitutive equation was established to describe the high temperature deformation behaviour of the material under the identified processing conditions. Standard statistical parameter such as correlation coefficient has been used to validate the established equation.

  9. Zero-voltage switching converter absorbing parasitic parameters for super high frequency induction heating

    Institute of Scientific and Technical Information of China (English)

    Zheng-shi WANG; Hui-ming CHEN

    2008-01-01

    This paper presents a novel mega-Hz-level super high frequency zero-voltage soft-switching converter for induction heating power supplies. The prominent advantage of this topology is that it can absorb both inductive and capacitive parasitic components in the converter. The switch devices operate in a zero-voltage soft-switching mode. Consequently, the high voltage and high current spikes caused by parasitic inductors or capacitors oscillation do not occur in this circuit, and the high power loss caused by high frequency switching can be greatly reduced. A large value inductor is adopted between the input capacitor and the switches, thus, this novel converter shares the benefits of both voltage-type and current-type circuits simultaneously, and there are no needs of dead time between two switches. The working principles in different modes are introduced, Results of simulation and experiments operated at around 1 MHz frequency verify the validity of parasitic components absorption and show that this converter is competent for super high frequency applications.

  10. Study on Plant Morphological Traits and Production Characteristics of Super High-Yielding Soybean

    Institute of Scientific and Technical Information of China (English)

    AO Xue; XIE Fu-ti; HAN Xiao-ri; ZHAO Ming-hui; ZHU Qian; LI Jie; ZHANG Hui-jun; WANG Hai-ying; YU Cui-mei; LI Chun-hong; YAO Xing-dong

    2013-01-01

    Super high-yielding soybean cultivar Liaodou 14, soybean cultivars from Ohio in the United States, and the common soybean cultivars from Liaoning Province, China, with similar geographic latitudes and identical pod-bearing habits were used as the study materials for a comparison of morphological traits and production characteristics to provide a theoretical basis for the breeding of improved super high-yielding soybean cultivars. Using a randomized block design, different soybean cultivars from the same latitude were compared under conventional and unconventional treatments for their production characteristics, including morphological traits, leaf area index (LAI), net photosynthesis rate, and dry matter accumulation. The specific characteristics of the super high-yielding soybean cultivar Liaodou 14 were analyzed. The results showed that the plant height of Liaodou 14 was significantly lower than that of the common cultivars from Liaoning, whereas the number of its main-stem nodes was higher than that of the cultivars from Ohio or Liaoning. A high pod density was observed in Liaodou 14 under conventional treatments. Under both conventional and unconventional treatments, the branch number of Liaodou 14 was markedly higher than that of the common cultivars from Liaoning, and its branch length and leaf inclination angle were significantly higher than those of common cultivars from Liaoning or Ohio. Only small changes in the leaf inclination angle were observed in Liaodou 14 treated with conventional or unconventional methods. Under each treatment, Liaodou 14 exhibited the lowest amplitude of reduction in SPAD values and net photosynthesis rates from the grain-filling to ripening stages;the cultivars from Ohio and the common cultivars from Liaoning exhibited more significant reductions. Liaodou 14 reached its peak LAI later than the other cultivars but maintained its LAI at a higher level for a longer duration. Under both conventional and unconventional treatments

  11. Nano-textured high sensitivity ion sensitive field effect transistors

    Energy Technology Data Exchange (ETDEWEB)

    Hajmirzaheydarali, M.; Sadeghipari, M.; Akbari, M.; Shahsafi, A.; Mohajerzadeh, S., E-mail: mohajer@ut.ac.ir [Thin Film and Nanoelectronics Lab, Nanoelectronics Center of Excellence, School of Electrical and Computer Engineering, University of Tehran, Tehran 143957131 (Iran, Islamic Republic of)

    2016-02-07

    Nano-textured gate engineered ion sensitive field effect transistors (ISFETs), suitable for high sensitivity pH sensors, have been realized. Utilizing a mask-less deep reactive ion etching results in ultra-fine poly-Si features on the gate of ISFET devices where spacing of the order of 10 nm and less is achieved. Incorporation of these nano-sized features on the gate is responsible for high sensitivities up to 400 mV/pH in contrast to conventional planar structures. The fabrication process for this transistor is inexpensive, and it is fully compatible with standard complementary metal oxide semiconductor fabrication procedure. A theoretical modeling has also been presented to predict the extension of the diffuse layer into the electrolyte solution for highly featured structures and to correlate this extension with the high sensitivity of the device. The observed ultra-fine features by means of scanning electron microscopy and transmission electron microscopy tools corroborate the theoretical prediction.

  12. Antimicrobial susceptibility pattern of bacterial isolates from wound infection and their sensitivity to antibiotic agents at super specialty hospital, Amravati city, India

    Directory of Open Access Journals (Sweden)

    Hrishikesh Sawdekar

    2015-02-01

    Full Text Available Background: Wound infection is one of the health problems that is caused and aggravated by the invasion of pathogenic organisms. Information on local pathogens and sensitivity to antimicrobial agent is crucial for successful treatment of wounds. So the present study was conducted to determine antimicrobial susceptibility pattern of bacterial isolates from wound infection and their sensitivity to antimicrobial agents. Methods: A retrospective study was conducted among patients with wound infection in Suyash super speciality hospital, from January 2012 to December 2013. Wound swab was collected using sterile cotton swabs and processed for bacterial isolation and susceptibility testing to Systemic antimicrobial agents. Results: In this study 78 bacterial isolates were recovered from 258 specimens showing an isolation rate of 31.2%. The predominant bacteria isolated from wounds were gram positive staphylococci 36 (46.2%, followed by gram negative streptococci 18 (23.1% gram negative pseudomonas 12 (15.4 % and gram negative proteus 8 (10.4%. The gram positive and gram negative bacteria constituted 68 (87.2% and 10 (12.8% of bacterial isolates; respectively. Conclusion: In the present study most of the pathogens isolated from wound isolates showed high rate of resistance to most commonly used newer antibiotics used to treat bacterial infections. Therefore, rational use of antibiotics should be practiced. [Int J Res Med Sci 2015; 3(2.000: 433-439

  13. Super-Resolution Imaging by Arrays of High-Index Spheres Embedded in Transparent Matrices

    CERN Document Server

    Allen, Kenneth W; Li, Yangcheng; Limberopoulos, Nicholaos I; Walker, Dennis E; Urbas, Augustine M; Astratov, Vasily N

    2014-01-01

    We fabricated thin-films made from polydimethylsiloxane (PDMS) with embedded high-index (n~1.9-2.2) microspheres for super-resolution imaging applications. To control the position of microspheres, such films can be translated along the surface of the nanoplasmonic structure to be imaged. Microsphere-assisted imaging, through these matrices, provided lateral resolution of ~{\\lambda}/7 in nanoplasmonic dimer arrays with an illuminating wavelength {\\lambda}=405 nm. Such thin films can be used as contact optical components to boost the resolution capability of conventional microscopes.

  14. Microstructures and constituents of super-high strength aluminum alloy ingots made through LFEC process

    Directory of Open Access Journals (Sweden)

    WANG Shuang

    2007-11-01

    Full Text Available Ingots of a new super-high strength Al-Zn-Mg-Cu-Zr alloy were produced respectively by low frequency electromagnetic casting (LFEC and by conventional direct chill (DC casting process. Microstructure and constituents of the ingots were studied. The results indicated that the LFEC process significantly refines microstructure and constituents of the alloy, and to some extent, decreases the area (or volume fraction of constituents and eutectic structure precipitated at grain boundaries. But, no difference in the type of constituents was observed between LFEC and DC ingots. The results also showed LFEC process can improve the as-cast mechanical properties.

  15. Stabilization of high and low solids Consolidated Incinerator Facility (CIF) waste with super cement

    Energy Technology Data Exchange (ETDEWEB)

    Walker, B.W.

    2000-01-11

    This report details solidification activities using selected Mixed Waste Focus Area technologies with the High and Low Solid waste streams. Ceramicrete and Super Cement technologies were chosen as the best possible replacement solidification candidates for the waste streams generated by the SRS incinerator from a list of several suggested Mixed Waste Focus Area technologies. These technologies were tested, evaluated, and compared to the current Portland cement technology being employed. Recommendation of a technology for replacement depends on waste form performance, process flexibility, process complexity, and cost of equipment and/or raw materials.

  16. Proposal to detect an emission of unusual super-high energy electrons in electron storage rings

    Directory of Open Access Journals (Sweden)

    Da-peng Qian

    2014-01-01

    Full Text Available According to an extended Lorentz–Einstein mass formula taken into the uncertainty principle, it is predicted that the electron beams passing accelerating electric field should with a small probability generate abnormal super-high energy electrons which are much higher than the beam energy. Author’s preliminary experiment result at electron storage ring has hinted these signs, so suggests to more strictly detect this unusual phenomenon, and thus to test the extended mass formula as well as a more perfect special relativity.

  17. Development of the super high angular resolution principle for X-ray imaging *

    Institute of Scientific and Technical Information of China (English)

    Chen Zhang; Shuang-Nan Zhang

    2011-01-01

    Development of the Super High Angular Resolution Principle (SHARP)for coded-mask X-ray imaging is presented. We prove that SHARP can be considered as a generalized coded mask imaging method with a coding pattern comprised of diffraction-interference fringes in the mask pattern. The angular resolution of SHARP can be improved by detecting the fringes more precisely than the mask's element size,i.e. by using a detector with a pixel size smaller than the mask's element size. The proposed mission SHARP-X for solar X-ray observations is also briefly discussed.

  18. A Super High Resolution Distance Measurement Method Based on Phase Comparison

    Institute of Scientific and Technical Information of China (English)

    LI Zhi-Qi; ZHOU Wei; MIAO Miao; ZHOU Hui; ZHENG Sheng-Feng

    2008-01-01

    @@ Phase comparison method can enhance the measurement resolution to 10-13/τ in time domain. This method can also be used in distance measurement in the navigation and positioning. We propose a super high-resolution distance measurement based on linear phase comparison method. A high resolution scheme is put forward on the basis of the research of major factors concerning the phase comparison in the distance measurement. Conversion of a high-linearity phase difference to voltage and high-resolution voltage meter make it possible to obtain a very high phase measurement resolution. When the purpose is to measure distance, the phase noise of frequency source used in the measurement can be reduced partly. Thus this method is favourable for high resolution distance measurement. The precision of the distance measurement can reach 0.1c ps with c being the velocity of light in vacuum.

  19. Bifunctional chimeric SuperCD suicide gene -YCD: YUPRT fusion is highly effective in a rat hepatoma model

    Institute of Scientific and Technical Information of China (English)

    Florian Graepler; Ulrike A Lauer; Reinhard Vonthein; Michael Gregor; Sorin Armeanu; Michael Bitzer; Ulrich M. Lauer; Marie-Luise Lemken; Wolfgang A Wybranietz; Ulrike Schmidt; Irina Smirnow; Christine D Groβ; Martin Spiegel; Andrea Schenk; Hansj(o)rg Graf

    2005-01-01

    AIM: To investigate the effects of catalytically superior gene-directed enzyme prodrug therapy systems on a rat hepatoma model.METHODS: To increase hepatoma cell chemosensitivity for the prodrug 5-fluorocytosine (5-FC), we generated a chimeric bifunctional SuperCD suicide gene, a fusion of the yeast cytosine deaminase (YCD) and the yeast uracil phosphoribosyltransferase (YUPRT) gene.RESULTS: In vitro stably transduced Morris rat hepatoma cells (MH) expressing the bifunctional SuperCD suicide gene (MH SuperCD) showed a clearly marked enhancement in cell killing when incubated with 5-FC as compared with MH ceils stably expressing YCD solely (MH YCD) or the cytosine deaminase gene of bacterial origin(MH BCD), respectively. In vivo, MH SuperCD tumors implanted both subcutaneously as well as orthotopically into the livers of syngeneic ACI rats demonstrated significant tumor regressions (P<0.01) under both high dose as well as low dose systemic 5-FC application,whereas MH tumors without transgene expression (MH naive) showed rapid progression. For the first time, an order of in vivo suicide gene effectiveness (SuperCD>>YCD > > BCD > > > negative control) was defi ned as a result of a directin vivo comparison of all three suicide genes.CONCLUSION: Bifunctional SuperCD suicide gene expression is highly effective in a rat hepatoma model,thereby significantly improving both the therapeutic index and the efficacy of hepatocellular carcinoma killing by fluorocytosine.

  20. Photonic Quantum Metrologies Using Photons: Phase Super-sensitivity and Entanglement-Enhanced Imaging

    Science.gov (United States)

    Takeuchi, Shigeki

    Quantum information science has been attracting significant attention recently. It harnesses the intrinsic nature of quantum mechanics such as quantum superposition, the uncertainty principle, and quantum entanglement to realize novel functions. Recently, quantum metrology has been emerging as an application of quantum information science. Among the many physical quanta, photons are an indispensable tool for metrology, as light-based measurements are applicable to fields ranging from astronomy to life science. In quantum metrology, quantum entanglement between photons is the phenomenon utilized.In this chapter, we will try to give a brief overview of this emerging field mainly focusing on two topics: Optical phase measurements beyond the standard quantum limit (SQL) and quantum optical coherence tomography (QOCT). The sensitivity of an optical phase measurement for a given photon number N is usually limited by N sqrt{N} , which is called the SQL or shot noise limit. However, the SQL can be overcome when non-classical light is used. We explain the basic concepts and the recent experimental results that exceed the SQL, and an application of this technology for microscopy. QOCT harnesses the quantum entanglement of photons in frequency to cancel out the dispersion effect, which degrades the resolution of conventional OCT. The mechanism of the dispersion cancellation and the latest experimental results will be given.

  1. The high-energy environment in the super-earth system CoRoT-7

    CERN Document Server

    Poppenhaeger, K; Schröter, S; Lalitha, S; Kashyap, V; Schmitt, J H M M

    2012-01-01

    High-energy irradiation of exoplanets has been identified to be a key influence on the stability of these planets' atmospheres. So far, irradiation-driven mass-loss has been observed only in two Hot Jupiters, and the observational data remain even more sparse in the super-earth regime. We present an investigation of the high-energy emission in the CoRoT-7 system, which hosts the first known transiting super-earth. To characterize the high-energy XUV radiation field into which the rocky planets CoRoT-7b and CoRoT-7c are immersed, we analyzed a 25 ks XMM-Newton observation of the host star. Our analysis yields the first clear (3.5 sigma) X-ray detection of CoRoT-7. We determine a coronal temperature of ca. 3 MK and an X-ray luminosity of 3*10^28 erg/s. The level of XUV irradiation on CoRoT-7b amounts to ca. 37000 erg/cm^2/s. Current theories for planetary evaporation can only provide an order-of-magnitude estimate for the planetary mass loss; assuming that CoRoT-7b has formed as a rocky planet, we estimate that...

  2. Weldability of 780 MPa Super-High Strength Heavy-Duty Truck Crossbeam Steel

    Institute of Scientific and Technical Information of China (English)

    WANG Xiao-nan; DI Hong-shuang; ZHANG Chit; DU Lin-xiu; DONG Xue-xir

    2012-01-01

    CO2-shielded welding experiments of newly developed, 780 MPa super-high strength heavy-duty truck crossbeam steel were conducted, and the microstructure, microhardness, mechanical properties, and impact tough- hess of the welded joint were studied. The evolution of the microstructure of the welded joint occurred as follows.. welding seam (acicular ferrite+proeutectoid ferrite)→fusion zone (granular bainite-long strip M/A island)→coarse grain zone (granular bainite-long strip or short bar M/A island)→fine grain zone (ferrite+ pearlite+ blocky M/A is- land)→mixed grained zone (ferrite+granular bainite+blocky M/A island)→base metal (proeutectoid ferrite+gran- ular bainite-hlocky or granular M/A island). Increasing the density of the grain boundaries can effectively improve the impact toughness, and the blocky M/A island hindered crack propagation more effectively than the long strip M/A island. The new hot-rolled 780 MPa super-high strength steel had excellent weldability. The welding technology was applied under the following conditions: welding voltage was 20 to 21 V, welding current was 200 to 210 A, and the gas flow rate was 25 L/rain.

  3. Meshing Highly Regular Structures: The Case of Super Carbon Nanotubes of Arbitrary Order

    Directory of Open Access Journals (Sweden)

    Christian Schröppel

    2015-01-01

    Full Text Available Mesh generation is an important step in many numerical methods. We present the “Hierarchical Graph Meshing” (HGM method as a novel approach to mesh generation, based on algebraic graph theory. The HGM method can be used to systematically construct configurations exhibiting multiple hierarchies and complex symmetry characteristics. The hierarchical description of structures provided by the HGM method can be exploited to increase the efficiency of multiscale and multigrid methods. In this paper, the HGM method is employed for the systematic construction of super carbon nanotubes of arbitrary order, which present a pertinent example of structurally and geometrically complex, yet highly regular, structures. The HGM algorithm is computationally efficient and exhibits good scaling characteristics. In particular, it scales linearly for super carbon nanotube structures and is working much faster than geometry-based methods employing neighborhood search algorithms. Its modular character makes it conducive to automatization. For the generation of a mesh, the information about the geometry of the structure in a given configuration is added in a way that relates geometric symmetries to structural symmetries. The intrinsically hierarchic description of the resulting mesh greatly reduces the effort of determining mesh hierarchies for multigrid and multiscale applications and helps to exploit symmetry-related methods in the mechanical analysis of complex structures.

  4. High-resolution WRF simulation of cloud properties over the super typhoon Haiyan: physics parameterizations and comparison against MODIS

    Science.gov (United States)

    Islam, Tanvir; Srivastava, Prashant K.; Dai, Qiang

    2016-11-01

    Numerical weather prediction (NWP) models can complement the satellite technology in simulating the cloud properties, especially in extreme storm events, when gathering new data becomes more than essential for accurate weather forecasting. In this study, we investigate the capability of the Weather Research and Forecasting (WRF) model to realistically simulate some important cloud properties in high-resolution grids, such as cloud phase (e.g., liquid or ice) and cloud water path. The sensitivity of different combinations of physics parameterizations to the simulated cloud fields is studied. The experiment is conducted on a super typhoon event by configuring the WRF model in two domains, with two-way nesting, allowing bidirectional information exchange between the parent and the nest. In order to do the assessment, the simulated cloud fields are compared against MODIS-derived cloud properties from one overpass scene. While the simulations have been able to capture the spatial distribution of cloud properties reasonably well, produced cloud quantities such as ice water path has been significantly overestimated when compared to the MODIS optical cloud information. The microphysics parameterizations are found to be more sensitive than the planetary boundary layer (PBL) parameterizations.

  5. Volume and structural analysis of super-cooled water under high pressure

    Science.gov (United States)

    Duki, Solomon F.; Tsige, Mesfin

    2012-02-01

    Motivated by recent experimental study of super-cooled water at high pressure [1], we performed atomistic molecular dynamic simulations study on bulk water molecules at isothermal-isobaric ensemble. These simulations are performed at temperatures that range from 40 K to 380 K using two different cooling rates, 10K/ns and 10K/5ns, and pressure that ranges from 1atm to 10000 atm. Our analysis for the variation of the volume of the bulk sample against temperature indicates a downward concave shape for pressures above certain values, as reported in [1]. The same downward concave behavior is observed at high pressure on the mean-squared-displacements (MSD) of the water molecules when the MSD is plotted against time. To get further insight on the effect of the pressure on the sample we have also performed a structural analysis of the sample.[4pt] [1] O. Mishima, J. Chem. Phys. 133, 144503 (2010);

  6. Arrayed Waveguide Gratings and Their Application Using Super-High-Δ Silica-Based Planar Lightwave Circuit Technology

    Science.gov (United States)

    Maru, Koichi; Uetsuka, Hisato

    This paper reviews our recent progress on arrayed waveguide gratings (AWGs) using super-high-Δ silica-based planar lightwave circuit (PLC) technology and their application to integrated optical devices. Factors affecting the chip size of AWGs and the impact of increasing relative index difference Δ on the chip size are investigated, and the fabrication result of a compact athermal AWG using 2.5%-Δ silica-based waveguides is presented. As an application of super-high-Δ AWGs to integrated devices, a flat-passband multi/demultiplexer consisting of an AWG and cascaded MZIs is presented.

  7. High sensitivity knitted fabric strain sensors

    Science.gov (United States)

    Xie, Juan; Long, Hairu; Miao, Menghe

    2016-10-01

    Wearable sensors are increasingly used in smart garments for detecting and transferring vital signals and body posture, movement and respiration. Existing fabric strain sensors made from metallized yarns have low sensitivity, poor comfort and low durability to washing. Here we report a knitted fabric strain sensor made from a cotton/stainless steel (SS) fibre blended yarn which shows much higher sensitivity than sensors knitted from metallized yarns. The fabric feels softer than pure cotton textiles owing to the ultrafine stainless steel fibres and does not lose its electrical property after washing. The reason for the high sensitivity of the cotton/SS knitted fabric sensor was explored by comparing its sensing mechanism with the knitted fabric sensor made from metallized yarns. The results show that the cotton/SS yarn-to-yarn contact resistance is highly sensitive to strain applied to hooked yarn loops.

  8. High Sensitivity deflection detection of nanowires

    Energy Technology Data Exchange (ETDEWEB)

    Sanii, Babak; Ashby, Paul

    2009-10-28

    A critical limitation of nanoelectromechanical systems (NEMS) is the lack of a high-sensitivity position detection mechanism. We introduce a noninterferometric optical approach to determine the position of nanowires with a high sensitivity and bandwidth. Its physical origins and limitations are determined by Mie scattering analysis. This enables a dramatic miniaturization of detectable cantilevers, with attendant reductions to the fundamental minimum force noise in highly damping environments. We measure the force noise of an 81{+-}9??nm radius Ag{sub 2}Ga nanowire cantilever in water at 6{+-}3??fN/{radical}Hz.

  9. Type III Dyson Sphere of Highly Advanced Civilizations around a Super Massive Black Hole

    CERN Document Server

    Inoue, Makoto

    2011-01-01

    We describe a new system for a society of highly advanced civilizations around a super massive black hole (SMBH), as an advanced Type III "Dyson Sphere", pointing out an efficient usage of energy for the advanced civilizations. SMBH also works as a sink for waste materials. Here we assume that Type III civilisations of Kardashev classification [1] form a galactic club [2] in a galaxy, and the energy from the SMBH will be delivered to the club members, forming an energy control system similar to power grids in our present society. The energy is probably transmitted by a sharp beam with coherent electro-magnetic waves, which provide a new concept for the search for extraterrestrial intelligence (SETI) via detection of such energy transmission signals. This expands the search window for other intelligences within the Universe.

  10. Crucial technologies in High the design of Xiluodu Super Arch Dam

    Institute of Scientific and Technical Information of China (English)

    Wang Renkun

    2012-01-01

    Some super high arch dams ( SHADs), like Xiluodu Arch Dam, after their heights reaching the magnitude of 300 m, confront lots of technical challenges in design and construction. Several crucial technologies of 6 SHADs will be reviewed and discussed in this and consecutive papers, including Xiluodu, Jinping I in China, Baktiary in Iran, ete. , on the topics of the research method, criterion for evaluation and engineering application of dam safety analysis and evaluation, reasonable dam base interface, dam shape optimization, comprehensive treatments of complex foundation, anti-seismic engineering, dam construction material, concrete placement and temperature control, instrumentation and monitoring of dam operation, etc. This paper will mainly focus on the overall safety of SHADs, reasonable dam base interface analysis and evaluation and their engineering application.

  11. A new ab initio approach to the development of high temperature super conducting materials

    CERN Document Server

    Turner, Philip

    2016-01-01

    We review recent theoretical developments, which suggest that a set of shared principles underpin macroscopic quantum phenomena observed in high temperature super conducting materials, room temperature coherence in photosynthetic processes and the emergence of long range order in biological structures. These systems are driven by dissipative systems, which lead to fractal assembly and a fractal network of charges (with associated quantum potentials) at the molecular scale. At critical levels of charge density and fractal dimension, individual quantum potentials merge to form a charged induced macroscopic quantum potential, which act as a structuring force dictating long range order. Whilst the system is only partially coherent (i.e. only the bosonic fields are coherent), within these processes many of the phenomena associated with standard quantum theory are recovered, with macroscopic quantum potentials and associated forces having their equivalence in standard quantum mechanics. We establish a testable hypo...

  12. High sensitivity optically pumped quantum magnetometer.

    Science.gov (United States)

    Tiporlini, Valentina; Alameh, Kamal

    2013-01-01

    Quantum magnetometers based on optical pumping can achieve sensitivity as high as what SQUID-based devices can attain. In this paper, we discuss the principle of operation and the optimal design of an optically pumped quantum magnetometer. The ultimate intrinsic sensitivity is calculated showing that optimal performance of the magnetometer is attained with an optical pump power of 20 μW and an operation temperature of 48°C. Results show that the ultimate intrinsic sensitivity of the quantum magnetometer that can be achieved is 327 fT/Hz(½) over a bandwidth of 26 Hz and that this sensitivity drops to 130 pT/Hz(½) in the presence of environmental noise. The quantum magnetometer is shown to be capable of detecting a sinusoidal magnetic field of amplitude as low as 15 pT oscillating at 25 Hz.

  13. Super-TIGER2: A Very-Large-Area, High-Resolution, Trans-Iron Cosmic Ray Investigation - Caltech Co-I

    Science.gov (United States)

    Mewaldt, Richard

    This is a Co-I proposal from the California Institute of Technology for the proposal entitled “SuperTIGER-2: A Very-Large-Area, High-Resolution Trans-Iron Cosmic Ray Investigation” submitted by Principal Investigator W. R. Binns of Washington University in St. Louis. SuperTIGER is a very-large-area instrument for measuring the composition of galactic cosmic rays on high-altitude balloon flights over Antarctica. Super-TIGER-1 had a highly successful 55-day flight in 2012/2013. The excellent data quality enables us to clearly resolve all nuclei from Z=10 to Z=40. Additionally, although statistics are low, there appears to be clear resolution of elements with Z=50-60. The excellent data from this flight will enable us to achieve the initial goals of the program. The high performance of the instrument, both in charge resolution and collecting power, and the science that can be addressed by measurements of Z>40 nuclei, makes a compelling case to conduct additional flights to measure the abundances of individual nuclei up to Z=60. This is a 4- year proposal with the primary objective of measuring the abundances of individual nuclei with 41#Z#60 and to substantially increase the number of 30#Z#40 nuclei measured. This will be the first time that individual elemental abundances for 41#Z#60 will be obtained. These new measurements will provide sensitive tests and clarification of the OB-association model of galactic cosmic-ray origins and will test models for atomic processes by which nuclei are selected for acceleration to cosmic-ray energies. They will enable us to determine if the enrichment of refractory elements (those that exist primarily in dust grains in the interstellar medium) over volatile elements (those that exist primarily in the gas phase) extends into the Z=41-60 charge range. They will also enable us to unambiguously determine the extent of any r-process enrichment. SuperTIGER provides critical measurements to unravel the mystery of galactic cosmic ray

  14. Super high precision 200 ppi liquid crystal display series; Chokoseido 200 ppi ekisho display series

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    In mobile equipment, in demand is a high precision liquid crystal display (LCD) having the power of expression equivalent to printed materials like magazines because of the necessity of displaying a large amount of information on a easily potable small screen. In addition, with the spread and high-quality image of digital still cameras, it is strongly desired to display photographed digital image data in high quality. Toshiba Corp., by low temperature polysilicone (p-Si) technology, commercialized the liquid crystal display series of 200 ppi (pixels per inch) precision dealing with the rise of the high-precision high-image quality LCD market. The super high precision of 200 ppi enables the display of smooth beautiful animation comparable to printed sheets of magazines and photographs. The display series are suitable for the display of various information services such as electronic books and electronic photo-viewers including internet. The screen sizes lined up are No. 4 type VGA (640x480 pixels) of a small pocket notebook size and No. 6.3 type XGA (1,024x768 pixels) of a paperback size, with a larger screen to be furthered. (translated by NEDO)

  15. High-temperature condensate clouds in super-hot Jupiter atmospheres

    Science.gov (United States)

    Wakeford, H. R.; Visscher, C.; Lewis, N. K.; Kataria, T.; Marley, M. S.; Fortney, J. J.; Mandell, A. M.

    2017-02-01

    Deciphering the role of clouds is central to our understanding of exoplanet atmospheres, as they have a direct impact on the temperature and pressure structure, and observational properties of the planet. Super-hot Jupiters occupy a temperature regime similar to low-mass M-dwarfs, where minimal cloud condensation is expected. However, observations of exoplanets such as WASP-12b (Teq ˜ 2500 K) result in a transmission spectrum indicative of a cloudy atmosphere. We re-examine the temperature and pressure space occupied by these super-hot Jupiter atmospheres, to explore the role of the initial Al- and Ti-bearing condensates as the main source of cloud material. Due to the high temperatures, a majority of the more common refractory material is not depleted into deeper layers and would remain in the vapour phase. The lack of depletion into deeper layers means that these materials with relatively low cloud masses can become significant absorbers in the upper atmosphere. We provide condensation curves for the initial Al- and Ti-bearing condensates which may be used to provide quantitative estimates of the effect of metallicity on cloud masses, as planets with metal-rich hosts potentially form more opaque clouds because more mass is available for condensation. Increased metallicity also pushes the point of condensation to hotter, deeper layers in the planetary atmosphere further increasing the density of the cloud. We suggest that planets around metal-rich hosts are more likely to have thick refractory clouds, and discuss the implication on the observed spectra of WASP-12b.

  16. Supertaster, super reactive: oral sensitivity for bitter taste modulates emotional approach and avoidance behavior in the affective startle paradigm.

    Science.gov (United States)

    Herbert, Cornelia; Platte, Petra; Wiemer, Julian; Macht, Michael; Blumenthal, Terry D

    2014-08-01

    People differ in both their sensitivity for bitter taste and their tendency to respond to emotional stimuli with approach or avoidance. The present study investigated the relationship between these sensitivities in an affective picture paradigm with startle responding. Emotion-induced changes in arousal and attention (pupil modulation), priming of approach and avoidance behavior (startle reflex modulation), and subjective evaluations (ratings) were examined. Sensitivity for bitter taste was assessed with the 6-n-propylthiouracil (PROP)-sensitivity test, which discriminated individuals who were highly sensitive to PROP compared to NaCl (PROP-tasters) and those who were less sensitive or insensitive to the bitter taste of PROP. Neither pupil responses nor picture ratings differed between the two taster groups. The startle eye blink response, however, significantly differentiated PROP-tasters from PROP-insensitive subjects. Facilitated response priming to emotional stimuli emerged in PROP-tasters but not in PROP-insensitive subjects at shorter startle lead intervals (200-300ms between picture onset and startle stimulus onset). At longer lead intervals (3-4.5s between picture onset and startle stimulus onset) affective startle modulation did not differ between the two taster groups. This implies that in PROP-sensitive individuals action tendencies of approach or avoidance are primed immediately after emotional stimulus exposure. These results suggest a link between PROP taste perception and biologically relevant patterns of emotional responding. Direct perception-action links have been proposed to underlie motivational priming effects of the startle reflex, and the present results extend these to the sensory dimension of taste.

  17. Stabilized super-thermite colloids: A new generation of advanced highly energetic materials

    Science.gov (United States)

    Elbasuney, Sherif; Gaber Zaky, M.; Radwan, Mostafa; Mostafa, Sherif F.

    2017-10-01

    One of the great impetus of nanotechnology on energetic materials is the achievement of nanothermites (metal-oxide/metal) which are characterized by massive heat output. Yet, full exploitation of super-thermites in highly energetic systems has not been achieved. This manuscript reports on the sustainable fabrication of colloidal Fe2O3 and CuO nanoparticles for thermite applications. TEM micrographs demonstrated mono-dispersed Fe2O3 and CuO with an average particle size of 3 and 15 nm respectively. XRD diffractograms demonstrated highly crystalline materials. SEM micrographs demonstrated a great tendency of the developed oxides to aggregate over drying process. The effective integration and dispersion of mono-dispersed colloidal thermite particles into energetic systems are vital for enhanced performance. Aluminum is of interest as highly energetic metal fuel. In this paper, synthesized Fe2O3 and CuO nanoparticles were re-dispersed in isopropyl alcohol (IPA) with aluminum nanoparticles using ultrasonic prope homogenizer. The colloidal thermite peraticles can be intgegrated into highly energetic system for subsequent nanocomposite development. Thanks to stabilization of colloidal CuO nanoparticles in IPA which could offer intimate mixing between oxidizer and metal fuel. The stabilization mechanism of CuO in IPA was correlated to steric stabilization with solvent molecules. This approach eliminated nanoparticle drying and the re-dispersion of dry aggregates into energetic materials. This manuscript shaded the light on the real development of colloidal thermite mixtures and their integration into highly energetic systems.

  18. Aluminum nanocantilevers for high sensitivity mass sensors

    DEFF Research Database (Denmark)

    Davis, Zachary James; Boisen, Anja

    2005-01-01

    We have fabricated Al nanocantilevers using a simple, one mask contact UV lithography technique with lateral and vertical dimensions under 500 and 100 nm, respectively. These devices are demonstrated as highly sensitive mass sensors by measuring their dynamic properties. Furthermore, it is shown ...

  19. Nonclassical characteristic functions for highly sensitive measurements

    CERN Document Server

    Richter, T; Richter, Th.

    2007-01-01

    Characteristic functions are shown to be useful for highly sensitive measurements. Redistributions of motional Fock states of a trapped atom can be directly monitored via the most fragile nonclassical part of the characteristic function. The method can also be used for decoherence measurements in optical quantum-information systems.

  20. Productive and vegetative behavior of olive cultivars in super high-density olive grove

    Directory of Open Access Journals (Sweden)

    Primo Proietti

    2015-02-01

    Full Text Available In recent years, there has been an increase in interest in super high-density (SHD olive (Olea europaea L. groves because they offer early entry into production, increased productivity and the possibility of using modified mechanical vine harvesters. This study was carried out in a young SHD olive grove to examine vegetative, histo-anatomical and productive characteristics and oil quality of the Spanish Arbequina and Italian Maurino and Leccino cultivars, characterized by low, low-to-medium and high vigor, respectively. Arbequina had low vigor and limited development in height and width, as well as a high leaf/wood ratio. Maurino had a canopy volume similar to that of Arbequina and, despite a great tendency to grow in height, had low vigor, a rather compact vegetative habitus, but good lighting in the canopy and high production efficiency. In Maurino, a greater palisade parenchyma height and a larger exposed lateral surface area of the palisade parenchyma cells were observed. In the fourth year after planting, fruit production of Arbequina was about 30 % less than Leccino and Maurino. The oil content on a dry weight basis was slightly higher in Arbequina and Maurino than in Leccino. Oil quality was good for all cultivars.

  1. High blood pressure and visual sensitivity

    Science.gov (United States)

    Eisner, Alvin; Samples, John R.

    2003-09-01

    The study had two main purposes: (1) to determine whether the foveal visual sensitivities of people treated for high blood pressure (vascular hypertension) differ from the sensitivities of people who have not been diagnosed with high blood pressure and (2) to understand how visual adaptation is related to standard measures of systemic cardiovascular function. Two groups of middle-aged subjects-hypertensive and normotensive-were examined with a series of test/background stimulus combinations. All subjects met rigorous inclusion criteria for excellent ocular health. Although the visual sensitivities of the two subject groups overlapped extensively, the age-related rate of sensitivity loss was, for some measures, greater for the hypertensive subjects, possibly because of adaptation differences between the two groups. Overall, the degree of steady-state sensitivity loss resulting from an increase of background illuminance (for 580-nm backgrounds) was slightly less for the hypertensive subjects. Among normotensive subjects, the ability of a bright (3.8-log-td), long-wavelength (640-nm) adapting background to selectively suppress the flicker response of long-wavelength-sensitive (LWS) cones was related inversely to the ratio of mean arterial blood pressure to heart rate. The degree of selective suppression was also related to heart rate alone, and there was evidence that short-term changes of cardiovascular response were important. The results suggest that (1) vascular hypertension, or possibly its treatment, subtly affects visual function even in the absence of eye disease and (2) changes in blood flow affect retinal light-adaptation processes involved in the selective suppression of the flicker response from LWS cones caused by bright, long-wavelength backgrounds.

  2. Highly Energetic, Low Sensitivity Aromatic Peroxy Acids.

    Science.gov (United States)

    Gamage, Nipuni-Dhanesha H; Stiasny, Benedikt; Stierstorfer, Jörg; Martin, Philip D; Klapötke, Thomas M; Winter, Charles H

    2016-02-18

    The synthesis, structure, and energetic materials properties of a series of aromatic peroxy acid compounds are described. Benzene-1,3,5-tris(carboperoxoic) acid is a highly sensitive primary energetic material, with impact and friction sensitivities similar to those of triacetone triperoxide. By contrast, benzene-1,4-bis(carboperoxoic) acid, 4-nitrobenzoperoxoic acid, and 3,5-dinitrobenzoperoxoic acid are much less sensitive, with impact and friction sensitivities close to those of the secondary energetic material 2,4,6-trinitrotoluene. Additionally, the calculated detonation velocities of 3,5-dinitrobenzoperoxoic acid and 2,4,6-trinitrobenzoperoxoic acid exceed that of 2,4,6-trinitrotoluene. The solid-state structure of 3,5-dinitrobenzoperoxoic acid contains intermolecular O-H⋅⋅⋅O hydrogen bonds and numerous N⋅⋅⋅O, C⋅⋅⋅O, and O⋅⋅⋅O close contacts. These attractive lattice interactions may account for the less sensitive nature of 3,5-dinitrobenzoperoxoic acid.

  3. High-performance supercapacitors using a nanoporous current collector made from super-aligned carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Zhou Ruifeng; Meng Chuizhou; Zhu Feng; Li Qunqing; Liu Changhong; Fan Shoushan; Jiang Kaili, E-mail: JiangKL@tsinghua.edu.cn [Department of Physics and Tsinghua-Foxconn Nanotechnology Research Center, Tsinghua University, Beijing 100084 (China)

    2010-08-27

    Nanoporous current collectors for supercapacitors have been fabricated by cross-stacking super-aligned carbon nanotube (SACNT) films as a replacement for heavy conventional metallic current collectors. The CNT-film current collectors have good conductivity, extremely low density (27 {mu}g cm{sup -2}), high specific surface area, excellent flexibility and good electrochemical stability. Nanosized active materials such as NiO, Co{sub 3}O{sub 4} or Mn{sub 2}O{sub 3} nanoparticles can be directly synthesized on the SACNT films by a straightforward one-step, in situ decomposition strategy that is both efficient and environmentally friendly. These composite films can be integrated into a pseudo-capacitor that does not use metallic current collectors, but nevertheless shows very good performance, including high specific capacitance ({approx}500 F g{sup -1}, including the current collector mass), reliable electrochemical stability (<4.5% degradation in 2500 cycles) and a very high rate capability (245 F g{sup -1} at 155 A g{sup -1}).

  4. High-latitude poynting flux from combined Iridium and SuperDARN data

    Directory of Open Access Journals (Sweden)

    C. L. Waters

    2004-09-01

    Full Text Available Field-aligned currents convey stress between the magnetosphere and ionosphere, and the associated low altitude magnetic and electric fields reflect the flow of electromagnetic energy to the polar ionosphere. We introduce a new technique to measure the global distribution of high latitude Poynting flux, S||, by combining electric field estimates from the Super Dual Auroral Radar Network (SuperDARN with magnetic perturbations derived using magnetometer data from the Iridium satellite constellation. Spherical harmonic methods are used to merge the data sets and calculate S|| for any magnetic local time (MLT from the pole to 60° magnetic latitude (MLAT. The effective spatial resolutions are 2° MLAT, 2h MLT, and the time resolution is about one hour due to the telemetry rate of the Iridium magnetometer data. The technique allows for the assessment of high-latitude net S|| and its spatial distribution on one hour time scales with two key advantages: (1 it yields the net S|| including the contribution of neutral winds; and (2 the results are obtained without recourse to estimates of ionosphere conductivity. We present two examples, 23 November 1999, 14:00-15:00 UT, and 11 March 2000, 16:00-17:00 UT, to test the accuracy of the technique and to illustrate the distributions of S|| that it gives. Comparisons with in-situ S|| estimates from DMSP satellites show agreement to a few mW/m2 and in the locations of S|| enhancements to within the technique's resolution. The total electromagnetic energy flux was 50GW for these events. At auroral latitudes, S|| tends to maximize in the morning and afternoon in regions less than 5° in MLAT by two hours in MLT having S||=10 to 20mW/m2 and total power up to 10GW. The power poleward of the Region 1 currents is about one

  5. Optimization design of foundation excavation for Xiluodu super-high arch dam in China

    Institute of Scientific and Technical Information of China (English)

    Qixiang Fan; Shaowu Zhou; Ning Yang

    2015-01-01

    With better understanding of the quality and physico-mechanical properties of rocks of dam foundation, and the physico-mechanical properties and structure design of arch dam in association with the foun-dation excavation of Xiluodu arch dam, the excavation optimization design was proposed for the foundation surface on the basis of feasibility study. Common analysis and numerical analysis results demonstrated the feasibility of using the weakly weathered rocks III1 and III2 as the foundation surface of super-high arch dam. In view of changes in the geological conditions at the dam foundation along the riverbed direction, the design of extending foundation surface excavation area and using consolidating grouting and optimizing structure of dam bottom was introduced, allowing for harmonization of the arch dam and foundation. Three-dimensional (3D) geomechanics model test and finite element analysis re-sults indicated that the dam body and foundation have good overload stability and high bearing capacity. The monitoring data showed that the behaviors of dam and foundation correspond with the designed patterns in the construction period and the initial operation period.

  6. Optimization design of foundation excavation for Xiluodu super-high arch dam in China

    Directory of Open Access Journals (Sweden)

    Qixiang Fan

    2015-04-01

    Full Text Available With better understanding of the quality and physico-mechanical properties of rocks of dam foundation, and the physico-mechanical properties and structure design of arch dam in association with the foundation excavation of Xiluodu arch dam, the excavation optimization design was proposed for the foundation surface on the basis of feasibility study. Common analysis and numerical analysis results demonstrated the feasibility of using the weakly weathered rocks III1 and III2 as the foundation surface of super-high arch dam. In view of changes in the geological conditions at the dam foundation along the riverbed direction, the design of extending foundation surface excavation area and using consolidating grouting and optimizing structure of dam bottom was introduced, allowing for harmonization of the arch dam and foundation. Three-dimensional (3D geomechanics model test and finite element analysis results indicated that the dam body and foundation have good overload stability and high bearing capacity. The monitoring data showed that the behaviors of dam and foundation correspond with the designed patterns in the construction period and the initial operation period.

  7. High-power production targets for the Super-FRS using a fast extraction scheme

    CERN Document Server

    Tahir, N A; Kojouharova, J; Roussel-Chomaz, P; Chishkine, V; Geissel, H; Hoffmann, Dieter H H; Kindler, B; Landre-Pellemoine, F; Lommel, B; Mittig, W; Münzenberg, G; Shutov, A; Weick, H; Yavor, M

    2003-01-01

    The high-power production target of the Super-FRS [H. Geissel et al., these Proceedings] will be irradiated by very intense heavy-ion beams which will be delivered from the future SIS100/200 [An International Accelerator Facility for Beams of Ions and Antiprotons, GSI-Report, 2001] synchrotron facility at the Gesellschaft fuer Schwerionenforschung (GSI) Darmstadt. This paper presents calculations of the thermodynamic and the hydrodynamic response of such a target, considering that a uranium ion beam with an energy of 1 GeV/u and an intensity of 10 sup 1 sup 2 particles will impinge within 50 ns on a solid carbon target with a thickness of 4 g/cm sup 2. Due to the high beam intensity the target may be strongly heated and could be destroyed in a single shot. The purpose of this work is to investigate with the help of two-dimensional numerical simulations how one can minimize target heating and avoid target destruction.

  8. Ultra - High Energy Cosmic Rays from decay of the Super Heavy Dark Matter Relics

    CERN Document Server

    Doroshkevich, A G

    2000-01-01

    In this paper we briefly discuss the problem of the origin of Ultra High Energy Cosmic Rays in the framework of Top-Down models. We show that, for high energy of decays and in a wide range of spectra of injected protons, their extragalactic flux is consistent with the observed fluxes of cosmic rays in the energy range 0.1 E_{GZK}< E < 10E_{GZK}. For suitable energy and spectra of injected protons, the contribution of galactic sources is moderate, in this energy range, but it dominates at smaller and larger energies. In such models we can expect that at these energies the anisotropy of cosmic rays distribution over sky will be especially small. Some possible manifestations of decays of super massive particles such as, for example, primordial black holes with masses M_{pbh} ~ 10^{-5} g, are considered. In particular, we show that partial conversion of energy released during these decays at redshifts z ~ 1000 to Ly-alpha photons can delay the hydrogen recombination and distort the spectrum of fluctuations ...

  9. A New Approach for Refining Carbide Dimensions in M42 Super Hard High-speed Steel

    Institute of Scientific and Technical Information of China (English)

    Xue-feng ZHOU; Wang-long ZHU; Hong-bing JIANG; Feng FANG; Yi-you TU; Jian-qing JIANG

    2016-01-01

    Obtaining small carbides is crucial but difficult for high-speed steels.A new approach for refining carbide dimensions in M42 super hard high-speed steel by increasing cooling rate and spheroidizing treatment was proposed. The morphologies and properties of eutectic carbides formed at different cooling rates were investigated by means of scanning electron microscopy (SEM),energy dispersive spectroscopy (EDS),X-ray diffraction (XRD),transmis-sion electron microscopy (TEM),electron back-scattered diffraction (EBSD)and differential scanning calorimeter (DSC).The results show that eutectic carbides change from a lamellar shape into a curved-rod shape as cooling rate increases.Despite different morphologies,the two carbides are both of M2 C type with a hexagonal close-packed structure and display a single crystal orientation in one eutectic colony.The morphology of M2 C mainly depends on the growing process of eutectic carbides,which is strongly influenced by cooling rate.Compared with lamellar car-bides,M2 C carbides with curved-rod shapes are less stable,and decompose into M6 C and MC at lower temperatures. They are more inclined to spheroidize during heating,which ultimately and distinguishably refines the carbide dimen-sions.As small carbides are much easier to dissolve into matrices during austenization,the process described herein improves the supersaturation of alloying elements in martensite,which leads to an increment of hardness in M42 steel.

  10. Preparation and application of hollow molecularly imprinted polymers with a super-high selectivity to the template protein.

    Science.gov (United States)

    Chen, Yang; He, Xi-Wen; Mao, Jie; Li, Wen-You; Zhang, Yu-Kui

    2013-10-01

    Protein-imprinted polymers with hollow cores that have a super-high imprinting factor were prepared by etching the core of the surface-imprinted polymers that used silica particles as the support. Lysozyme as template was modified onto the surface of silica particles by a covalent method, and after polymerization and the removal of template molecules, channels through the polymer layer were formed, which allowed a single-protein molecule to come into the hollow core and attach to the binding sites inside the polymer layer. The adsorption experiments demonstrated that the hollow imprinted polymers had an extremely high binding capacity and selectivity, and thus a super-high imprinting factor was obtained. The as-prepared imprinted polymers were used to separate the template lysozyme from egg white successfully, indicating its high selectivity and potential application in the field of separation of protein from real samples.

  11. Highly sensitive catalytic spectrophotometric determination of ruthenium

    Science.gov (United States)

    Naik, Radhey M.; Srivastava, Abhishek; Prasad, Surendra

    2008-01-01

    A new and highly sensitive catalytic kinetic method (CKM) for the determination of ruthenium(III) has been established based on its catalytic effect on the oxidation of L-phenylalanine ( L-Pheala) by KMnO 4 in highly alkaline medium. The reaction has been followed spectrophotometrically by measuring the decrease in the absorbance at 526 nm. The proposed CKM is based on the fixed time procedure under optimum reaction conditions. It relies on the linear relationship where the change in the absorbance (Δ At) versus added Ru(III) amounts in the range of 0.101-2.526 ng ml -1 is plotted. Under the optimum conditions, the sensitivity of the proposed method, i.e. the limit of detection corresponding to 5 min is 0.08 ng ml -1, and decreases with increased time of analysis. The method is featured with good accuracy and reproducibility for ruthenium(III) determination. The ruthenium(III) has also been determined in presence of several interfering and non-interfering cations, anions and polyaminocarboxylates. No foreign ions interfered in the determination ruthenium(III) up to 20-fold higher concentration of foreign ions. In addition to standard solutions analysis, this method was successfully applied for the quantitative determination of ruthenium(III) in drinking water samples. The method is highly sensitive, selective and very stable. A review of recently published catalytic spectrophotometric methods for the determination of ruthenium(III) has also been presented for comparison.

  12. Dynamic analyses of steel-reinforced super high-strength concrete columns

    Institute of Scientific and Technical Information of China (English)

    JIA Jinqing; JIANG Rui; HOU Tong; XU Shilang

    2007-01-01

    The dynamic behaviors of steel-reinforced super high-strength concrete columns under seismic loading were studied with a series of experiments. Thirteen specimens, with concrete strengths ranging from 94.9 to 105.4 Mpa and shear-span ratios of 2.75, were manufactured. The axial load ratio and the stirrup reinforcement ratio were the main experimental variables affecting the dynamic behavior of the specimens. The columns under low cyclic lateral loading mainly failed in the flexural-shear mode. Shear force- displacement hysteretic curves and skeleton curves were drawn. The coefficients of the specimens' displacement ductility were calculated. Experimental results indicate that ductility decreases while the axial load ratio increases, but it increases when the stirrup reinforcement ratio increases. The limit values of the axial load ratio and the minimum stirrup reinforcement ratio of the columns were investigated to satisfy definite ductility requirements. These values were suggested as references of engineering applications and of the amendment of the current Chinese design code of steel reinforced concrete composite structures.

  13. Application of evaporative cooling technology in super-high power density magnet.

    Science.gov (United States)

    Xiong, B; Ruan, L; Gu, G B; Guo, S Q; Cao, R; Li, Z G; Lu, W; Zhang, X Z; Sun, L T; Zhao, H W

    2014-02-01

    Evaporative cooling technology utilizes phase-change heat transfer mode to achieve the cooling for heating equipment. The heat transfer capacity of evaporative cooling technology is far more than air or water cooling technology. The Electron Cyclotron Resonance ion source magnet is a typical super-high power density magnet, and the evaporative cooling technology is an ideal cooling method for the coils of magnet. In this paper we show the structure and process of coils and the special design of flow channels of coolant for an experiment magnet model. Additionally, the heat transfer circulation is presented and analyzed. By the finite element method, the flow channels are optimized to rationally allocate coolant and to reduce the temperature of coils. For the experiment model, the current density of copper wire of coils is 19 A/mm(2), and the coil-windows current density is larger than 12 A/mm(2). The max temperature of coils is below 80 °C, and the total heat is about 200 kW.

  14. Kinetics and Microstructural Investigation of High-Temperature Oxidation of IN-738LC Super Alloy

    Science.gov (United States)

    Hamidi, S.; Rahimipour, M. R.; Eshraghi, M. J.; Hadavi, S. M. M.; Esfahani, H.

    2017-02-01

    The present study was carried out to investigate the kinetics and the surface chemistry of the oxide layers formed on the IN-738LC super alloy during high-temperature oxidation at 950 °C in air from 1 to 260 h. Oxidation kinetics were studied by mass gain measurement. The oxide layers were characterized by field emission scanning electron microscope, elemental distribution map, energy-dispersive spectroscopy as well as x-ray diffractometry (XRD). The oxidation kinetics followed the parabolic law. The XRD analysis revealed that the oxide scale contained mainly NiO, Ni (Cr, Al)2O4, Al2O3, TiO2 and Cr2O3. The oxide structure, from the top surface down to the substrate, was clarified by elemental map distribution studies as Ni-Ti oxides, Cr-Ti oxides, Cr2O3 oxide band, Ni-Co-Cr-W oxide and finally a blocky Al2O3 region. The oxidation scales were composed of three distinct layers of the outer and mid layers enriched by TiO2 and Cr2O3, NiCr2O4 oxide, respectively, and the innermost layer was composed of Al2O3 and matrix alloy. The depleted gamma prime layer was formed under the oxidation scales due to the impoverishment of Al and Ti which were induced by the formation of Al2O3 and TiO2.

  15. High-sensitive cardiac troponin T

    Institute of Scientific and Technical Information of China (English)

    Ru-Yi Xu; Xiao-Fa Zhu; Ye Yang; Ping Ye

    2013-01-01

    Cardiac troponin is the preferred biomarker for the diagnosis of acute myocardial infarction (AMI). The recent development of a high-sensitive cardiac troponin T (hs-cTnT) assay permits detection of very low levels of cTnT. Using the hs-cTnT assay improves the overall diagnostic accuracy in patients with suspected AMI, while a negative result also has a high negative predictive value. The gain in sensitivity may be particularly important in patients with a short duration from symptom onset to admission. Measurement of cardiac troponin T with the hs-cTnT assay may provide strong prognostic information in patients with acute coronary syndromes, stable coronary artery disease, heart failure and even in the general population; however, increased sensitivity comes at a cost of decreased specificity. Serial testing, as well as clinical context and co-existing diseases, are likely to become increasingly important for the interpretation of hs-cTnT assay results.

  16. Viewing-distance aware super-resolution for high-definition display.

    Science.gov (United States)

    Shen, Chih-Tsung; Liu, Hung-Hsun; Yang, Ming-Hsuan; Hung, Yi-Ping; Pei, Soo-Chang

    2015-01-01

    In this paper, we propose a novel algorithm for high-definition displays to enlarge low-resolution images while maintaining perceptual constancy (i.e., the same field-of-view, perceptual blur radius, and the retinal image size in viewer's eyes). We model the relationship between a viewer and a display by considering two main aspects of visual perception, i.e., scaling factor and perceptual blur radius. As long as we enlarge an image while adjust its image blur levels on the display, we can maintain viewer's perceptual constancy. We show that the scaling factor should be set in proportion to the viewing distance and the blur levels on the display should be adjusted according to the focal length of a viewer. Toward this, we first refer to edge directions to interpolate a low-resolution image with the increasing of viewing distance and the scaling factor. After images are interpolated, we utilize a local contrast to estimate the spatially varying image blur levels of the interpolated image. We then further adjust the image blur levels using a parametric deblurring method, which combines L1 as well as L2 reconstruction errors, and Tikhonov with total variation regularization terms. By taking these factors into account, high-resolution images adaptive to viewing distance on a display can be generated. Experimental results on both natural image metric and user subjective studies across image scales demonstrate that the proposed super-resolution algorithm for high-definition displays performs favorably against the state-of-the-art methods.

  17. Super-Twisting Differentiator-Based High Order Sliding Mode Voltage Control Design for DC-DC Buck Converters

    Directory of Open Access Journals (Sweden)

    Yigeng Huangfu

    2016-06-01

    Full Text Available This paper aims to focus on the smooth output of DC-DC buck converters in wireless power transfer systems under input perturbations and load disturbances using the high-order sliding mode controller (HOSM and HOSM with super-twisting differentiator (HOSM + STD. The proposed control approach needs only measurement of converter output voltage. Theoretical analysis and design procedures, as well as the super-twisting differentiator of the proposed controller are presented in detail with the prescribed convergence law of high-order sliding modes. Comparisons of both simulation and experimental results among conventional proportional-integral (PI control, traditional sliding mode control (SMC, HOSM and HOSM + STD under various test conditions such as steady state, input voltage perturbations and output load disturbances, are presented and discussed. The results demonstrate and validate the effectiveness and robustness of the proposed control method.

  18. High blocking temperature in SnO{sub 2} based super-paramagnetic diluted magnetic semiconductor

    Energy Technology Data Exchange (ETDEWEB)

    Mounkachi, O., E-mail: o.mounkachi@mascir.com [Institute of Nanomaterials and Nanotechnology, MAScIR, Rabat (Morocco); Institut Néel, CNRS et Université Joseph Fourier, BP 166, F-38042 Grenoble cedex 9 (France); Salmani, E. [LMPHE, associé au CNRST (URAC 12), Faculté des Sciences, Université Mohammed V-Agdal, Rabat (Morocco); El Moussaoui, H. [Institute of Nanomaterials and Nanotechnology, MAScIR, Rabat (Morocco); Masrour, R. [Laboratory of Materials, Processes, Environment and Quality, Cady Ayyed University, National School of Applied Sciences, Safi (Morocco); Institut Néel, CNRS et Université Joseph Fourier, BP 166, F-38042 Grenoble cedex 9 (France); Hamedoun, M. [Institute of Nanomaterials and Nanotechnology, MAScIR, Rabat (Morocco); Ez-Zahraouy, H. [LMPHE, associé au CNRST (URAC 12), Faculté des Sciences, Université Mohammed V-Agdal, Rabat (Morocco); Hlil, E.K. [Institut Néel, CNRS et Université Joseph Fourier, BP 166, F-38042 Grenoble cedex 9 (France); Benyoussef, A. [Institute of Nanomaterials and Nanotechnology, MAScIR, Rabat (Morocco); LMPHE, associé au CNRST (URAC 12), Faculté des Sciences, Université Mohammed V-Agdal, Rabat (Morocco)

    2014-11-25

    Highlights: • Simple doping, (Sn,Fe)O{sub 2} exhibits a soft ferromagnetism at low temperature. • High blocking temperature was observed for Cu doped (Sn,Fe)O{sub 2} nanocrystalline. • Experimental results are confirmed by ab initio calculations. - Abstract: (Fe,Cu)-doped SnO{sub 2} nanocrystals was synthesized using the co-precipitation method. Magnetic Properties Measurement System (MPMS) revealed that for simple doping, Fe-doped SnO{sub 2} soft ferromagnetism at low temperature appears, while the ferromagnetic phase is stable at temperature higher than room temperature for Cu co-doping element. The ferromagnetism is significantly enhanced by the Cu addition to Fe-doped SnO{sub 2}, according to the ZFC and FC magnetizations and the hysteresis loops. The evidences for the existence of superparamagnetism are characterized and high blocking temperature super-paramagnetism in (Fe,Cu)-doped SnO{sub 2} nanocrystals was observed. Based on first-principles calculations, we have investigated electronic structures and magnetic properties of Fe-doped SnO{sub 2} and (Fe,Cu)-doped SnO{sub 2} with and without defect with LDA and LDA-SIC approximations. The results suggest that the oxygen vacancies (V{sub O}) play a critical role in the activation of ferromagnetism in Fe doped SnO{sub 2}. For (Fe,Cu)-doped SnO{sub 2} the results exhibit that Cu strongly influences on the magnetic properties of these doped systems which are in good agreement with the experimental observations. Electronic structure show that the presence of Cu promote the ferromagnetic bound magnetic polaron interaction through the carriers introduce by d (Cu)

  19. Photodetector having high speed and sensitivity

    Science.gov (United States)

    Morse, Jeffrey D.; Mariella, Jr., Raymond P.

    1991-01-01

    The present invention provides a photodetector having an advantageous combination of sensitivity and speed; it has a high sensitivity while retaining high speed. In a preferred embodiment, visible light is detected, but in some embodiments, x-rays can be detected, and in other embodiments infrared can be detected. The present invention comprises a photodetector having an active layer, and a recombination layer. The active layer has a surface exposed to light to be detected, and comprises a semiconductor, having a bandgap graded so that carriers formed due to interaction of the active layer with the incident radiation tend to be swept away from the exposed surface. The graded semiconductor material in the active layer preferably comprises Al.sub.1-x Ga.sub.x As. An additional sub-layer of graded In.sub.1-y Ga.sub.y As may be included between the Al.sub.1-x Ga.sub.x As layer and the recombination layer. The recombination layer comprises a semiconductor material having a short recombination time such as a defective GaAs layer grown in a low temperature process. The recombination layer is positioned adjacent to the active layer so that carriers from the active layer tend to be swept into the recombination layer. In an embodiment, the photodetector may comprise one or more additional layers stacked below the active and recombination layers. These additional layers may include another active layer and another recombination layer to absorb radiation not absorbed while passing through the first layers. A photodetector having a stacked configuration may have enhanced sensitivity and responsiveness at selected wavelengths such as infrared.

  20. High sensitivity troponin and valvular heart disease.

    Science.gov (United States)

    McCarthy, Cian P; Donnellan, Eoin; Phelan, Dermot; Griffin, Brian P; Sarano, Maurice Enriquez-; McEvoy, John W

    2017-01-16

    Blood-based biomarkers have been extensively studied in a range of cardiovascular diseases and have established utility in routine clinical care, most notably in the diagnosis of acute coronary syndrome (e.g., troponin) and the management of heart failure (e.g., brain-natriuretic peptide). The role of biomarkers is less well established in the management of valvular heart disease (VHD), in which the optimal timing of surgical intervention is often challenging. One promising biomarker that has been the subject of a number of recent VHD research studies is high sensitivity troponin (hs-cTn). Novel high-sensitivity assays can detect subclinical myocardial damage in asymptomatic individuals. Thus, hs-cTn may have utility in the assessment of asymptomatic patients with severe VHD who do not have a clear traditional indication for surgical intervention. In this state-of-the-art review, we examine the current evidence for hs-cTn as a potential biomarker in the most commonly encountered VHD conditions, aortic stenosis and mitral regurgitation. This review provides a synopsis of early evidence indicating that hs-cTn has promise as a biomarker in VHD. However, the impact of its measurement on clinical practice and VHD outcomes needs to be further assessed in prospective studies before routine clinical use becomes a reality.

  1. [Characteristics of canopy structure of super high yielding japonica hybrid rice community].

    Science.gov (United States)

    Chen, Jinhong; Zhang, Guoping; Guo, Hengde; Mao, Guojuan

    2003-06-01

    In this paper, the characteristics of canopy structure, such as the numbers of seedling, panicle and grain, the distribution of dry matters in different canopy layers and different organs, and the distributions of LAI and of solar radiation in different canopy layers of super high yielding community of japonica hybrid rice were studied, in comparison with normal japonica rice. The results showed that the total the dry matter weight and the dry matter weight of layers below 40 cm, 40-60 cm, 60-80 cm and above 80 cm of japonica hybrid rice canopy were 32.29%, 29.12%, 13.95%, 16.45% and 100.17% higher those that of normal japonica rice, respectively. The ratios of dry leaf (photosynthetic organ) and of dry panicle (sink organ) weight to total dry weight were 24.8% and 12.8%, respectively, which were greater than those of normal japonica rice, while the ratios of dry sheath and stem (storage organs) weight were 33.6% and 28.9%, respectively, which were lower than those of normal japonica rice. The allotment of LAI in different layers of japonica hybrid rice canopy was reasonable, and the LAI of above 40 cm layer at full heading stage reached 5.44. The solar radiation was well-distributed inside japonica hybrid rice canopy, for example, the solar radiation in layers below 60 cm were 13.1%-37.0% higher, but 5.9%-12.2% lower above 60 cm than that of normal japonica rice. The extinction coefficients of solar radiation in layers below 20 cm, 20-40 cm, 40-60 cm and 60-80 cm of japonica hybrid rice canopy were 35.1%, 13.5%, 29.1% and 17.2% lower than that of normal japonica rice, respectively.

  2. Single objective light-sheet microscopy for high-speed whole-cell 3D super-resolution.

    Science.gov (United States)

    Meddens, Marjolein B M; Liu, Sheng; Finnegan, Patrick S; Edwards, Thayne L; James, Conrad D; Lidke, Keith A

    2016-06-01

    We have developed a method for performing light-sheet microscopy with a single high numerical aperture lens by integrating reflective side walls into a microfluidic chip. These 45° side walls generate light-sheet illumination by reflecting a vertical light-sheet into the focal plane of the objective. Light-sheet illumination of cells loaded in the channels increases image quality in diffraction limited imaging via reduction of out-of-focus background light. Single molecule super-resolution is also improved by the decreased background resulting in better localization precision and decreased photo-bleaching, leading to more accepted localizations overall and higher quality images. Moreover, 2D and 3D single molecule super-resolution data can be acquired faster by taking advantage of the increased illumination intensities as compared to wide field, in the focused light-sheet.

  3. Three-dimensional super-wideband micro-antenna for high-resolution millimeter-wave medical imaging.

    Science.gov (United States)

    Mirbeik, Amir; Tavassoli, Vahid; Ayazi, Farrokh; Tavassolian, Negar

    2014-01-01

    This paper reports on a novel super-wideband micro-hemispherical antenna with application in millimeter-wave medical imaging. The antenna is composed of a hemispherical shell suspended above a substrate and can be fabricated using a fabrication technology originally developed for micron-scale electromechanical resonators. The antenna exhibits a wide fractional bandwidth of more than 80% (from 64 GHz to 150 GHz) and a high gain of 8.6 dBi at its center frequency. Radiation parameters of the antenna are characterized and the effect of its super-wideband behavior on pulsed millimeter-wave imaging is demonstrated. Finally, a preliminary array configuration composed of two antennas placed side-by-side in the vicinity of a skin-mimicking target is evaluated and the ability to fully detect the target has been demonstrated.

  4. New views of the human NK cell immunological synapse: recent advances enabled by super- and high- resolution imaging techniques

    Directory of Open Access Journals (Sweden)

    Emily M. Mace

    2013-01-01

    Full Text Available Imaging technology has undergone rapid growth with the development of super resolution microscopy, which enables resolution below the diffraction barrier of light (~200 nm. In addition, new techniques for single molecule imaging are being added to the cell biologist’s arsenal. Immunologists have exploited these techniques to advance understanding of NK biology, particularly that of the immune synapse. The immune synapse’s relatively small size and complex architecture combined with its exquisitely controlled signaling milieu have made it a challenge to visualize. In this review we highlight and discuss new insights into NK cell immune synapse formation and regulation revealed by cutting edge imaging techniques, including super resolution microscopy and high resolution total internal reflection microscopy and Förster resonance energy transfer.

  5. Super continuum generation at 800 nm in highly nonlinear photonic crystal fibers with normal dispersion

    DEFF Research Database (Denmark)

    Hansen, Kim Per; Larsen, Jacob Juul; Jensen, Jacob Riis

    2001-01-01

    More than 90 nm broad self-phase modulation (SPM) induced pulses have been created from both 25 and 50 fs pulses in just 12.5 cm of fiber. The broadening is more than 2.5 times that observed in standard SMF. SPM broadening in PCFs has several advantages over more complex super continuum generation...

  6. Analysis of the Key and Difficult Points in the Engineering Construction Technology of the Steel Structures of a Super High-rise Building

    Science.gov (United States)

    Dou, Lijun; Li, Hengxu

    2017-07-01

    In recent years, with the rapid development of the economy of China, the traditional building structure has not been able to meet the current people’s demands and the super high-rise building has become a symbol of a city. In the current period, the research on the super high-rise building in the architectural industry of China is late and the technical blanks exist in some construction difficulties in the super high-rise steel structures. Based on the above, a brief analysis and discussion on the difficult construction technology in the steel structures of a super high-rise building and some measures are presented for reference of the relevant personnel in this paper.

  7. Highly Sensitive Electro-Optic Modulators

    Energy Technology Data Exchange (ETDEWEB)

    DeVore, Peter S [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-10-26

    There are very important diagnostic and communication applications that receive faint electrical signals to be transmitted over long distances for capture. Optical links reduce bandwidth and distance restrictions of metal transmission lines; however, such signals are only weakly imprinted onto the optical carrier, resulting in low fidelity transmission. Increasing signal fidelity often necessitates insertion of radio-frequency (RF) amplifiers before the electro-optic modulator, but (especially at high frequencies) RF amplification results in large irreversible distortions. We have investigated the feasibility of a Sensitive and Linear Modulation by Optical Nonlinearity (SALMON) modulator to supersede RF-amplified modulators. SALMON uses cross-phase modulation, a manifestation of the Kerr effect, to enhance the modulation depth of an RF-modulated optical wave. This ultrafast process has the potential to result in less irreversible distortions as compared to a RF-amplified modulator due to the broadband nature of the Kerr effect. Here, we prove that a SALMON modulator is a feasible alternative to an RFamplified modulator, by demonstrating a sensitivity enhancement factor greater than 20 and significantly reduced distortion.

  8. Super-resolution

    DEFF Research Database (Denmark)

    Nasrollahi, Kamal; Moeslund, Thomas B.

    2014-01-01

    Super-resolution, the process of obtaining one or more high-resolution images from one or more low-resolution observations, has been a very attractive research topic over the last two decades. It has found practical applications in many real world problems in different fields, from satellite...... the contributions of different authors to the basic concepts of each group. Furthermore, common issues in super-resolution algorithms, such as imaging models and registration algorithms, optimization of the cost functions employed, dealing with color information, improvement factors, assessment of super...

  9. Evolution of undissolved phases in high-zinc content super-high strength aluminum alloy during ageing

    Institute of Scientific and Technical Information of China (English)

    张坤; 刘志义; 叶呈武; 许晓嫦; 郑青春

    2004-01-01

    The evolution of undissolved phases in the high-zinc content super-high strength aluminum alloy during ageing was investigated by means of SEM and EIS. The results show that undissolved phases of Cu-rich M(AlZnMgCu) exist in the silver-free alloy at solid-solution state. With increasing the ageing time, the precipitation of agehardening precipitates MgZn2 stimulates Zn atoms within the undissolved phases to diffuse into the matrix, and thus the Cu content in the M(AlZnMgCu) phase increases relatively. For the silver-bearing alloy, small addition of Ag promotes the formation of Ag-rich M(A1ZnMgCuAg) undissolved phases and deteriorates mechanical properties of the alloy. At the early stage of ageing, Ag content within the M(AlZnMgCuAg) phases greatly decreases due to rapid diffusing of Ag atoms into the matrix and the co-clustering of Ag and Mg atoms. As the ageing time prolonging, the precipitation of MgZn2 results in the decrease of Zn content in the undissolved phases, and the relative increase of Ag and Mg contents.

  10. Heterogeneous catalysis in highly sensitive microreactors

    DEFF Research Database (Denmark)

    Olsen, Jakob Lind

    This thesis present a highly sensitive silicon microreactor and examples of its use in studying catalysis. The experimental setup built for gas handling and temperature control for the microreactor is described. The implementation of LabVIEW interfacing for all the experimental parts makes...... automated experiments and data collection possible. An argon ush at the O-rings (used to interface the silicon microreactor with the gas system), which was developed, is presented. It enables experiments with temperatures up to 400., and up to 500. for short periods of time. The CO oxidation reaction...... of adsorbates readily converted to methanol as the source of the transient increase in methanol production, is eliminated. A study of mass selected ruthenium nanoparticles from a magnetron-sputter gas-aggregation source, deposited in microreactors, is presented. It is, shown that CO methanation can be measured...

  11. High-sensitivity fiber optic acoustic sensors

    Science.gov (United States)

    Lu, Ping; Liu, Deming; Liao, Hao

    2016-11-01

    Due to the overwhelming advantages compared with traditional electronicsensors, fiber-optic acoustic sensors have arisen enormous interest in multiple disciplines. In this paper we present the recent research achievements of our group on fiber-optic acoustic sensors. The main point of our research is high sensitivity interferometric acoustic sensors, including Michelson, Sagnac, and Fabry-Pérot interferometers. In addition, some advanced technologies have been proposed for acoustic or acoustic pressure sensing such as single-mode/multimode fiber coupler, dual FBGs and multi-longitudinal mode fiber laser based acoustic sensors. Moreover, our attention we have also been paid on signal demodulation schemes. The intensity-based quadrature point (Q-point) demodulation, two-wavelength quadrature demodulation and symmetric 3×3 coupler methodare discussed and compared in this paper.

  12. High sensitive radiation detector for radiology dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Valente, M.; Malano, F. [Instituto de Fisica Enrique Gaviola, Oficina 102 FaMAF - UNC, Av. Luis Medina Allende, Ciudad Universitaria, 5000 Cordoba (Argentina); Molina, W.; Vedelago, J., E-mail: valente@famac.unc.edu.ar [Laboratorio de Investigaciones e Instrumentacion en Fisica Aplicada a la Medicina e Imagenes por Rayos X, Laboratorio 448 FaMAF - UNC, Ciudad Universitaria, 5000 Cordoba (Argentina)

    2014-08-15

    Fricke solution has a wide range of applications as radiation detector and dosimetry. It is particularly appreciated in terms of relevant comparative advantages, like tissue equivalence when prepared in aqueous media like gel matrix, continuous mapping capability, dose rate recorded and incident direction independence as well as linear dose response. This work presents the development and characterization of a novel Fricke gel system, based on modified chemical compositions making possible its application in clinical radiology. Properties of standard Fricke gel dosimeter for high dose levels are used as starting point and suitable chemical modifications are introduced and carefully investigated in order to attain high resolution for low dose ranges, like those corresponding to radiology interventions. The developed Fricke gel radiation dosimeter system achieves the expected typical dose dependency, actually showing linear response in the dose range from 20 up to 4000 mGy. Systematic investigations including several chemical compositions are carried out in order to obtain a good enough dosimeter response for low dose levels. A suitable composition among those studied is selected as a good candidate for low dose level radiation dosimetry consisting on a modified Fricke solution fixed to a gel matrix containing benzoic acid along with sulfuric acid, ferrous sulfate, xylenol orange and ultra-pure reactive grade water. Dosimeter samples are prepared in standard vials for its in phantom irradiation and further characterization by spectrophotometry measuring visible light transmission and absorbance before and after irradiation. Samples are irradiated by typical kV X-ray tubes and calibrated Farmer type ionization chamber is used as reference to measure dose rates inside phantoms in at vials locations. Once sensitive material composition is already optimized, dose-response curves show significant improvement regarding overall sensitivity for low dose levels. According to

  13. High sensitivity field asymmetric ion mobility spectrometer

    Science.gov (United States)

    Chavarria, Mario A.; Matheoud, Alessandro V.; Marmillod, Philippe; Liu, Youjiang; Kong, Deyi; Brugger, Jürgen; Boero, Giovanni

    2017-03-01

    A high sensitivity field asymmetric ion mobility spectrometer (FAIMS) was designed, fabricated, and tested. The main components of the system are a 10.6 eV UV photoionization source, an ion filter driven by a high voltage/high frequency n-MOS inverter circuit, and a low noise ion detector. The ion filter electronics are capable to generate square waveforms with peak-to-peak voltages up to 1000 V at frequencies up to 1 MHz with adjustable duty cycles. The ion detector current amplifier has a gain up to 1012 V/A with an effective equivalent input noise level down to about 1 fA/Hz1/2 during operation with the ion filter at the maximum voltage and frequency. The FAIMS system was characterized by detecting different standard chemical compounds. Additionally, we investigated the use of a synchronous modulation/demodulation technique to improve the signal-to-noise ratio in FAIMS measurements. In particular, we implemented the modulation of the compensation voltage with the synchronous demodulation of the ion current. The analysis of the measurements at low concentration levels led to an extrapolated limit of detection for acetone of 10 ppt with an averaging time of 1 s.

  14. High intensity uranium beams from the superHILAC and the bevatron: final report

    Energy Technology Data Exchange (ETDEWEB)

    1982-03-01

    The two injectors formerly used at the SuperHILAC were a 750-kV air-insulated Cockcroft-Walton (EVE) and a 2.5-MV pressurized HV multiplier (ADAM). The EVE injector can deliver adequate intensities of ions up to mass 40 (argon). The ADAM injector can accelerate ions with lower charge-to-mass ratios, and they can produce beams of heavier ions. The intensity of these beams decreases as the mass number increases, with the lowest practical intensity being achieved with lead beams. Experience with the two existing injectors provided substantial help in defining the general requirements for a new injector which would provide ample beams above mass 40. The requirements for acceptance by the first tank of the SuperHILAC are a particle velocity ..beta.. = 0.0154 (corresponding to an energy of 113 keV/amu) and a charge-to-mass ratio of 0.046 or larger. Present ion source performance dictates an air-insulated Cockcroft-Walton as a pre-accelerator because of its easy accessibility and its good overall reliability. The low charge state ions then receive further acceleration and, if necessary, subsequent stripping to the required charge state before injection into the SuperHILAC. A low-beta linac of the Widereoe type has been built to perform this acceleration. The injector system described consists of a Cockcroft-Walton pre-injector, injection beam lines and isotope analysis, a low-velocity linear accelerator, and SuperHILAC control center modifications.

  15. High-Efficiency Retrofit Lessons for Retail from a SuperTarget: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Langner, R.; Deru, M.; Hirsch, A.; Williams, S.

    2013-02-01

    The National Renewable Energy Laboratory partnered with Target under the Commercial Building Program to design and implement a retrofit of a SuperTarget in Thornton, CO. The result was a retrofit design that predicted 37% energy savings over ASHRAE Standard 90.1-2004, and 29% compared to existing (pre-retrofit) store consumption. The largest savings came from energy efficient lighting, energy efficient cooling systems, improved refrigeration, and better control of plug loads.

  16. Ultra-sensitive and super-resolving angular rotation measurement based on photon orbital angular momentum using parity measurement.

    Science.gov (United States)

    Zhang, Zijing; Qiao, Tianyuan; Ma, Kun; Cen, Longzhu; Zhang, Jiandong; Wang, Feng; Zhao, Yuan

    2016-08-15

    Photon orbital angular momentum has led to many novel insights and applications in quantum measurement. Photon orbital angular momentum can increase the resolution and sensitivity of angular rotation measurement. However, quantum measurement strategy can further surpass this limit and improve the resolution of angular rotation measurement. This Letter proposes and demonstrates a parity measurement method in angular rotation measurement scheme for the first time. Parity measurement can make the resolution superior to the limit of the existing method. The sensitivity can be improved with higher orbital angular momentum photons. Moreover, this Letter gives a detailed discussion of the change of resolution and sensitivity in the presence of photon loss.

  17. Highly sensitive direct conversion ultrasound interferometer

    Science.gov (United States)

    Svitelskiy, Oleksiy; Grossmann, John; Suslov, Alexey

    2015-03-01

    Being invented more than fifty years ago, the ultrasonic pulse-echo technique has proven itself as a valuable and indispensable non-destructive tool to explore elastic properties of materials in engineering and scientific tasks. We propose a new design for the instrument based on mass-produced integral microchips. In our design the radiofrequency echo-pulse signal is processed by AD8302 RF gain and phase detector (www.analog.com).Its phase output is linearly proportional to the phase difference between the exciting and response signals. The gain output is proportional to the log of the ratio of amplitudes of the received to the exciting signals. To exclude the non-linear fragments and to enable exploring large phase changes, we employ parallel connection of two detectors, fed by in-phase and quadrature signals respectively. The instrument allowed us exploring phase transitions with precision of ΔV / V ~10-7 (V is the ultrasound speed). The high sensitivity of the logarithmic amplifiers embedded into AD8302 requires good grounding and screening of the receiving circuitry.

  18. Super-resolution

    DEFF Research Database (Denmark)

    Nasrollahi, Kamal; Moeslund, Thomas B.

    2014-01-01

    and aerial imaging to medical image processing, to facial image analysis, text image analysis, sign and number plates reading, and biometrics recognition, to name a few. This has resulted in many research papers, each developing a new super-resolution algorithm for a specific purpose. The current......Super-resolution, the process of obtaining one or more high-resolution images from one or more low-resolution observations, has been a very attractive research topic over the last two decades. It has found practical applications in many real world problems in different fields, from satellite...... the contributions of different authors to the basic concepts of each group. Furthermore, common issues in super-resolution algorithms, such as imaging models and registration algorithms, optimization of the cost functions employed, dealing with color information, improvement factors, assessment of super...

  19. Noise evaluation of silicon strip super-module with ABCN250 readout chips for the ATLAS detector upgrade at the High Luminosity LHC

    Energy Technology Data Exchange (ETDEWEB)

    Todome, K., E-mail: todome@hep.phys.titech.ac.jp [Department of Physics, Tokyo Institute of Technology, Ookayama 2-12-1, Meguro-ku, Tokyo 152-8551 (Japan); Solid State Div., Hamamatsu Photonics K.K., 1126-1, Ichino-cho, Higashi-ku, Hamamatsu-shi, Shizuoka 435-8558 (Japan); Jinnouchi, O. [Department of Physics, Tokyo Institute of Technology, Ookayama 2-12-1, Meguro-ku, Tokyo 152-8551 (Japan); Solid State Div., Hamamatsu Photonics K.K., 1126-1, Ichino-cho, Higashi-ku, Hamamatsu-shi, Shizuoka 435-8558 (Japan); Clark, A.; Barbier, G.; Cadoux, F.; Favre, Y.; Ferrere, D.; Gonzalez-Sevilla, S.; Iacobucci, G.; La Marra, D.; Perrin, E.; Weber, M. [DPNC, University of Geneva, CH-1211 Geneva 4 (Switzerland); Solid State Div., Hamamatsu Photonics K.K., 1126-1, Ichino-cho, Higashi-ku, Hamamatsu-shi, Shizuoka 435-8558 (Japan); Ikegami, Y.; Nakamura, K.; Takubo, Y.; Unno, Y. [Institute of Particle and Nuclear Study, KEK, Oho 1-1, Tsukuba, Ibaraki 305-0801 (Japan); Solid State Div., Hamamatsu Photonics K.K., 1126-1, Ichino-cho, Higashi-ku, Hamamatsu-shi, Shizuoka 435-8558 (Japan); Takashima, R. [Department of Science Education, Kyoto University of Education, Kyoto 612-8522 (Japan); Solid State Div., Hamamatsu Photonics K.K., 1126-1, Ichino-cho, Higashi-ku, Hamamatsu-shi, Shizuoka 435-8558 (Japan); Tojo, J. [Department of Physics, Faculty of Science, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395 (Japan); Solid State Div., Hamamatsu Photonics K.K., 1126-1, Ichino-cho, Higashi-ku, Hamamatsu-shi, Shizuoka 435-8558 (Japan); Kono, T. [Ochadai Academic Production, Ochanomizu University, 2-1-1, Otsuka, Bunkyo-ku, Tokyo 112-8610 (Japan); Solid State Div., Hamamatsu Photonics K.K., 1126-1, Ichino-cho, Higashi-ku, Hamamatsu-shi, Shizuoka 435-8558 (Japan); and others

    2016-09-21

    Toward High Luminosity LHC (HL-LHC), the whole ATLAS inner tracker will be replaced, including the semiconductor tracker (SCT) which is the silicon micro strip detector for tracking charged particles. In development of the SCT, integration of the detector is the important issue. One of the concepts of integration is the “super-module” in which individual modules are assembled to produce the SCT ladder. A super-module prototype has been developed to demonstrate its functionality. One of the concerns in integrating the super-modules is the electrical coupling between each module, because it may increase intrinsic noise of the system. To investigate the electrical performance of the prototype, the new Data Acquisition (DAQ) system has been developed by using SEABAS. The electric performance of the super-module prototype, especially the input noise and random noise hit rate, was investigated by using SEABAS system.

  20. High Sensitivity, High Frequency and High Time Resolution Decimetric Spectroscope

    Science.gov (United States)

    Sawant, H. S.; Rosa, R. R.

    1990-11-01

    RESUMEN. Se ha desarrollado el primer espectroscopio decimetrico latino americano operando en una banda de 100 MHz con alta resoluci6n de fre- cuencia (100 KHz) y tiempo (10 ms), alrededor de cualquier centro de frecuencia en el intervalo de 2000-200 MHz. El prop6sito de esta nota es describir investigaciones solares y no solares que se planean, progra ma de investigaci6n y la situaci6n actual de desarrollo de este espectroscopio. ABSTRACT. First Latin American Decimetric Spectroscope operating over a band of 100 MHz with high resolution in frequency (100 KHz) and time (10 ms), around any center frequency in the range of 2000-200 MHz is being developed. The purpose of this note is to describe planned solar, and non-solar, research programmes and present status of development of this spectroscope. Keq wo : INSTRUMENTS - SPECTROSCOPY

  1. Development of A Super High Speed Permanent Magnet Synchronous Motor (PMSM Controller and Analysis of The Experimental Results

    Directory of Open Access Journals (Sweden)

    Limei Zhao

    2005-02-01

    Full Text Available This paper presents the design and implementation of a DSP-based controller for a super high-speed (>80,000 rpm permanent magnet synchronous motor (PMSM. The PMSM is a key component of the centrifugal compressor drive of a reverse Brayton cryocooler that is currently under development for NASA and Florida Solar Energy Center. The design of the PMSM open-loop control is presented. Experimental results with open-loop control schemes are presented. System optimization and analysis are also illustrated. They verify the effectiveness of the controller design and the optimization scheme.

  2. Construction and Use of Resting 12-Lead High Fidelity ECG "SuperScores" in Screening for Heart Disease

    Science.gov (United States)

    Schlegel, T. T.; Arenare, B.; Greco, E. C.; DePalma, J. L.; Starc, V.; Nunez, T.; Medina, R.; Jugo, D.; Rahman, M.A.; Delgado, R.

    2007-01-01

    We investigated the accuracy of several conventional and advanced resting ECG parameters for identifying obstructive coronary artery disease (CAD) and cardiomyopathy (CM). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. Multiple conventional and advanced ECG parameters were studied for their individual and combined retrospective accuracies in detecting underlying disease, the advanced parameters falling within the following categories: 1) Signal averaged ECG, including 12-lead high frequency QRS (150-250 Hz) plus multiple filtered and unfiltered parameters from the derived Frank leads; 2) 12-lead P, QRS and T-wave morphology via singular value decomposition (SVD) plus signal averaging; 3) Multichannel (12-lead, derived Frank lead, SVD lead) beat-to-beat QT interval variability; 4) Spatial ventricular gradient (and gradient component) variability; and 5) Heart rate variability. Several multiparameter ECG SuperScores were derivable, using stepwise and then generalized additive logistic modeling, that each had 100% retrospective accuracy in detecting underlying CM or CAD. The performance of these same SuperScores was then prospectively evaluated using a test set of another 120 individuals (40 new individuals in each of the CM, CAD and control groups, respectively). All 12-lead ECG SuperScores retrospectively generated for CM continued to perform well in prospectively identifying CM (i.e., areas under the ROC curve greater than 0.95), with one such score (containing just 4 components) maintaining 100% prospective accuracy. SuperScores retrospectively generated for CAD performed somewhat less accurately, with prospective areas under the ROC curve typically in the 0.90-0.95 range. We conclude that resting 12-lead

  3. SuperDARN CUTLASS Finland radar observations of high-latitude magnetic reconnections under northward interplanetary magnetic field (IMF) conditions

    Institute of Scientific and Technical Information of China (English)

    ZHANG QingHe; LIU RuiYuan; YANG HuiGen; HU HongQiao; ZHANG BeiChen; DUNLOP Malcolm; LESTER Mark; BOGDANOVA Yulia; WALSH Andrew

    2012-01-01

    A number of backscatter power enhancement events with “equatorward-moving radar auroral forms” in the high-latitude ionosphere were observed by SuperDARN CUTLASS Finland radar when the IMF was northward during 09:00 -10:00 UT on 26 March 2004.These events were also associated with sunward flow enhancements at each location in the Northern Hemisphere which were shown in ionospheric convections measured by the SuperDARN radars.These are typical features of high-latitude (lobe) magnetic reconnections.The durations of the velocity enhancements imply that the evolution time of the lobe reconnections is about 8-16 min from their origin at the reconnection site to their addition to the magnetotail lobe again.In additional,the Double Star TC-1 spacecraft was moving from magnetosheath into magnetosphere,and crossing the magnetopause near the subsolar region during this interval,and observed typical low-latitude magnetic reconnection signatures.This infers that the dayside high- and low-latitude reconnections may occur simultaneously.

  4. Super Special Codes using Super Matrices

    CERN Document Server

    Kandasamy, W B Vasantha; Ilanthenral, K

    2010-01-01

    The new classes of super special codes are constructed in this book using the specially constructed super special vector spaces. These codes mainly use the super matrices. These codes can be realized as a special type of concatenated codes. This book has four chapters. In chapter one basic properties of codes and super matrices are given. A new type of super special vector space is constructed in chapter two of this book. Three new classes of super special codes namely, super special row code, super special column code and super special codes are introduced in chapter three. Applications of these codes are given in the final chapter.

  5. Super Fuzzy Matrices and Super Fuzzy Models for Social Scientists

    CERN Document Server

    Kandasamy, W B Vasantha; Amal, K

    2008-01-01

    This book introduces the concept of fuzzy super matrices and operations on them. This book will be highly useful to social scientists who wish to work with multi-expert models. Super fuzzy models using Fuzzy Cognitive Maps, Fuzzy Relational Maps, Bidirectional Associative Memories and Fuzzy Associative Memories are defined here. The authors introduce 13 multi-expert models using the notion of fuzzy supermatrices. These models are described with illustrative examples. This book has three chapters. In the first chaper, the basic concepts about super matrices and fuzzy super matrices are recalled. Chapter two introduces the notion of fuzzy super matrices adn their properties. The final chapter introduces many super fuzzy multi expert models.

  6. The case for super-critical accretion on massive black holes at high redshift

    CERN Document Server

    Volonteri, Marta

    2014-01-01

    Short-lived intermittent phases of super-critical (super-Eddington) growth, coupled with star formation via feedback, may account for early growth of massive black holes (MBH) and coevolution with their host spheroids. We estimate the possible growth rates and duty cycles of these episodes, assuming slim disk solutions, where the emerging luminosity depends logarithmically on the accretion rate. As long as radiation is trapped in the disk, the effective radiative efficiency is low and several short episodes (~1e4 years) are possible, especially if energy flows through collimated funnels and feedback is limited. When the host galaxy is able to sustain inflow rates at 1-100 msun/yr, replenishing and circulation lead to a sequence of short episodes that may increase the growth rates of MBHs, with respect to an Eddington-limited case, by several orders of magnitude in ~ 1e7 years. Our model for e MBH growth predicts that the ratio of MBH accretion rate to star formation rate is 1e-2 or higher, naturally leading t...

  7. A joint compressed-sensing and super-resolution approach for very high-resolution diffusion imaging.

    Science.gov (United States)

    Ning, Lipeng; Setsompop, Kawin; Michailovich, Oleg; Makris, Nikos; Shenton, Martha E; Westin, Carl-Fredrik; Rathi, Yogesh

    2016-01-15

    Diffusion MRI (dMRI) can provide invaluable information about the structure of different tissue types in the brain. Standard dMRI acquisitions facilitate a proper analysis (e.g. tracing) of medium-to-large white matter bundles. However, smaller fiber bundles connecting very small cortical or sub-cortical regions cannot be traced accurately in images with large voxel sizes. Yet, the ability to trace such fiber bundles is critical for several applications such as deep brain stimulation and neurosurgery. In this work, we propose a novel acquisition and reconstruction scheme for obtaining high spatial resolution dMRI images using multiple low resolution (LR) images, which is effective in reducing acquisition time while improving the signal-to-noise ratio (SNR). The proposed method called compressed-sensing super resolution reconstruction (CS-SRR), uses multiple overlapping thick-slice dMRI volumes that are under-sampled in q-space to reconstruct diffusion signal with complex orientations. The proposed method combines the twin concepts of compressed sensing and super-resolution to model the diffusion signal (at a given b-value) in a basis of spherical ridgelets with total-variation (TV) regularization to account for signal correlation in neighboring voxels. A computationally efficient algorithm based on the alternating direction method of multipliers (ADMM) is introduced for solving the CS-SRR problem. The performance of the proposed method is quantitatively evaluated on several in-vivo human data sets including a true SRR scenario. Our experimental results demonstrate that the proposed method can be used for reconstructing sub-millimeter super resolution dMRI data with very good data fidelity in clinically feasible acquisition time.

  8. Super High Dosing with a Novel Buttiauxella Phytase Continuously Improves Growth Performance, Nutrient Digestibility, and Mineral Status of Weaned Pigs.

    Science.gov (United States)

    Zeng, Zhikai; Li, Qingyun; Tian, Qiyu; Zhao, Panfeng; Xu, Xiao; Yu, Shukun; Piao, Xiangshu

    2015-11-01

    This study was conducted to evaluate the efficacy of a novel Buttiauxella phytase to pigs fed P-deficient, corn-soybean meal diets. One hundred and twenty crossbred piglets (9.53 ± 0.84 kg) were allocated to one of five treatments which consisted of four low P diets (0.61 % Ca and 0.46 % total P) supplemented with 0, 500, 1,000, or 20,000 FTU/kg phytase as well as a positive control diet (0.77 % Ca and 0.62 % total P). Each treatment had six replicated pens with four pigs per pen. Pigs were fed the experimental diets for 28 days. Phytase supplementation linearly improved (P phytase (20,000 FTU/kg) further increased (P phytase inclusion group, as well as ATTD of Ca and P. Metacarpal bone characteristics and several trace mineral concentration in bone, plasma, or organ tissues were linearly (P phytase. Super high dosing with phytase (20,000 FTU/kg) supplementation improved (P phytase supplementation (500 or 1,000 FTU/kg). In conclusion, supplementation of 500 FTU of Buttiauxella phytase/kg and above effectively hydrolyzed phytate in a low-P corn-soybean diet for pigs. In addition, a super high dosing with phytase (20,000 FTU/kg) improved macro- or micro mineral availability and growth performance.

  9. Further resolution enhancement of high-sensitivity laser scanning photothermal microscopy applied to mouse endogenous

    Science.gov (United States)

    Nakata, Kazuaki; Tsurui, Hiromichi; Kobayashi, Takayoshi

    2016-12-01

    Photothermal microscopy has intrinsically super resolution capability due to the bilinear dependence of signal intensity of pump and probe. In the present paper, we have made further resolution improvement of high-sensitivity laser scanning photothermal microscopy by applying non-linear detection. By this, the new method has the following advantages: (1) super resolution with 61% and 42% enhancement from the diffraction limit values of the probe and pump wavelengths, respectively, by a second-order non-linear scheme, (2) compact light source using inexpensive conventional diode lasers, (3) wide applicability to nonfluorescent materials such as gold nanoparticles (GNPs) and hematoxylin-eosin stained biological samples, (4) relative robustness to optical damage, and (5) a high-frame rate using a Galvano mirror. The maximum resolution is determined to be 160 nm in the second-order non-linear detection mode and 270 nm in the linear detection mode by the PT signal of GNPs. The pixel rate and frame rate for 300 × 300 pixel image are 50 μs and 4.5 s, respectively. The pixel and frame rate are shorter than the rates, which are 1 ms and 100 s, respectively, using the piezo-driven stage system.

  10. [A simple highly sensitive recording microspectrophotometer].

    Science.gov (United States)

    Govardovskiĭ, V I; Zueva, L V

    1988-04-01

    A design of the recording microspectrophotometer is described. The instrument possesses an absolutely flat base line and quantum-noise limited detection threshold. Two principal elements of the design are the "jumping" stage, and the logarithmic amplifier with the phase-sensitive detector which converts the photomultiplier output into the optical density signal. The performance of the instrument is illustrated by the recordings of visual pigment spectra in single photoreceptors.

  11. Search for Diffuse Astrophysical Neutrino Flux Using Ultra-High Energy Upward-Going Muons in Super-Kamiokande I

    CERN Document Server

    Swanson, M E C; Hosaka, J; Iida, T; Ishihara, K; Kameda, J; Koshio, Y; Minamino, A; Mitsuda, C; Miura, M; Moriyama, S; Nakahata, M; Obayashi, Y; Ogawa, H; Shiozawa, M; Suzuki, Y; Takeda, A; Takeuchi, Y; Ueshima, K; Higuchi, I; Ishihara, C; Ishitsuka, M; Kajita, T; Kaneyuki, K; Mitsuka, G; Nakayama, S; Nishino, H; Okada, A; Okumura, K; Saji, C; Takenaga, Y; Clark, S; Desai, S; Dufour, F; Kearns, E; Likhoded, S; Litos, M; Raaf, Jennifer L; Stone, J L; Sulak, L R; Wang, W; Goldhaber, M; Casper, D; Cravens, J P; Dunmore, J; Kropp, W R; Liu, D W; Mine, S; Regis, C; Smy, M B; Sobel, H W; Vagins, M R; Ganezer, K S; Hill, J E; Keig, W E; Jang, J S; Kim, J Y; Lim, I T; Scholberg, K; Tanimoto, N; Walter, C W; Wendell, R; Ellsworth, R W; Tasaka, S; Guillian, G; Learned, J G; Matsuno, S; Messier, M D; Hayato, Y; Ichikawa, A K; Ishida, T; Ishii, T; Iwashita, T; Kobayashi, T; Nakadaira, T; Nakamura, K; Nitta, K; Oyama, Y; Totsuka, Y; Suzuki, A T; Hasegawa, M; Hiraide, K; Kato, I; Maesaka, H; Nakaya, T; Nishikawa, K; Sasaki, T; Sato, H; Yamamoto, S; Yokoyama, M; Haines, T J; Dazeley, S; Hatakeyama, S; Svoboda, R; Sullivan, G W; Turcan, D; Cooley, J; Mahn, K B M; Habig, A; Fukuda, Y; Sato, T; Itow, Y; Koike, T; Jung, C K; Kato, T; Kobayashi, K; Malek, M; McGrew, C; Sarrat, A; Terri, R; Yanagisawa, C; Tamura, N; Sakuda, M; Sugihara, M; Kuno, Y; Yoshida, M; Kim, S B; Yang, B S; Yoo, J; Ishizuka, T; Okazawa, H; Choi, Y; Seo, H K; Gando, Y; Hasegawa, T; Inoue, K; Ishii, H; Nishijima, K; Ishino, H; Watanabe, Y; Koshiba, M; Kielczewska, D; Zalipska, J; Berns, H G; Gran, R; Shiraishi, K K; Stachyra, A; Thrane, E; Washburn, K; Wilkes, R J002626770 100 L; Adams, J

    2006-01-01

    Many astrophysical models predict a diffuse flux of high energy neutrinos from active galactic nuclei and other extra-galactic sources. At muon energies above a TeV, the upward-going muon flux induced by neutrinos from active galactic nuclei is expected to exceed the flux due to atmospheric neutrinos. We have performed a search for this astrophysical neutrino flux by looking for upward-going muons in the highest energy data sample from the Super-Kamiokande detector using 1679.6 live days of data. We found 1 extremely high energy upward-going muon event, compared with an expected atmospheric neutrino background of 0.46 plus or minus 0.23 events. Using this result, we set an upper limit on the diffuse flux of upward-going muons due to neutrinos from astrophysical sources in the muon energy range 3.16-100 TeV.

  12. Super Factories

    Indian Academy of Sciences (India)

    D G Hitlin

    2006-11-01

    Heavy-flavor physics, in particular and physics results from the factories, currently provides strong constraints on models of physics beyond the Standard Model. A new generation of colliders, Super Factories, with 50 to 100 times the luminosity of existing colliders, can, in a dialog with LHC and ILC, provide unique clarification of new physics phenomena seen at those machines.

  13. Dedicated Searches for Low and High Mass Wimps with the SuperCDMS Soudan iZIP Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Welliver, Bradford [Florida State U.

    2016-01-01

    Recent cosmological evidence suggests most of the mass of the universe takes the form of a type of particle that we have not been able to directly detect. Nearly 80 years that have elapsed since the rst hints of this dark matter started to appear from astronomers without any direct detection. The high precision era of cosmology and unifying models of particle physics developed in the 20 th century have presented us with an exciting mystery at the intersection of these two elds that needs to be solved. SuperCDMS Soudan operates specialized germanium detectors (iZIPs) that are cooled to milliKelvin temperatures deep underground in the Soudan Underground Laboratory with the hope of detecting a rare collision between dark matter and a nucleus. A search for low-mass dark matter comes with multiple unique challenges since the background discrimination abilities of these detectors becomes less powerful at the low energies needed to probe low-mass dark matter since the signal to noise ratio deteriorates. Using a sophisticated background model via a pulse rescaling technique, SuperCDMS Soudan was able to produce a world leading exclusion limit on low-mass dark matter. Effort is to extend the analysis to higher masses require long running times during which many aspects of the detectors or the environment can change. Additional challenges are offered by the powerful background discrimination ability of the iZIP. The background distributions are well separated from the signal region, meaning most of the leakage arises from low-probability tails of the background distributions. In the absence of an enormous dataset, extrapolations from the bulk of the distribution are required. While attempting to obtain a model of gamma induced electron-recoils leaking into the signal region of the detector from high radius a curious asymmetry between the sides of the detectors was discovered potentially indicating an electronics or detector design problem. This thesis describes the physics

  14. Modeling high adsorption capacity and kinetics of organic macromolecules on super-powdered activated carbon.

    Science.gov (United States)

    Matsui, Yoshihiko; Ando, Naoya; Yoshida, Tomoaki; Kurotobi, Ryuji; Matsushita, Taku; Ohno, Koichi

    2011-02-01

    The capacity to adsorb natural organic matter (NOM) and polystyrene sulfonates (PSSs) on small particle-size activated carbon (super-powdered activated carbon, SPAC) is higher than that on larger particle-size activated carbon (powdered-activated carbon, PAC). Increased adsorption capacity is likely attributable to the larger external surface area because the NOM and PSS molecules do not completely penetrate the adsorbent particle; they preferentially adsorb near the outer surface of the particle. In this study, we propose a new isotherm equation, the Shell Adsorption Model (SAM), to explain the higher adsorption capacity on smaller adsorbent particles and to describe quantitatively adsorption isotherms of activated carbons of different particle sizes: PAC and SPAC. The SAM was verified with the experimental data of PSS adsorption kinetics as well as equilibrium. SAM successfully characterized PSS adsorption isotherm data for SPACs and PAC simultaneously with the same model parameters. When SAM was incorporated into an adsorption kinetic model, kinetic decay curves for PSSs adsorbing onto activated carbons of different particle sizes could be simultaneously described with a single kinetics parameter value. On the other hand, when SAM was not incorporated into such an adsorption kinetic model and instead isotherms were described by the Freundlich model, the kinetic decay curves were not well described. The success of the SAM further supports the adsorption mechanism of PSSs preferentially adsorbing near the outer surface of activated carbon particles.

  15. Effect of weld heat input on toughness and structure of HAZ of a new super-high strength steel

    Indian Academy of Sciences (India)

    Wang Juan; Li Yajiang; Liu Peng

    2003-04-01

    Fracture morphology and fine structure in the heat-affected zone (HAZ) of HQ130 super-high strength steel are studied by means of SEM, TEM and electron diffraction technique. Test results indicated that the structure of HAZ of HQ130 steel was mainly lath martensite (ML), in which there were a lot of dislocations in the sub-structure inside ML lath, the dislocation density was about (0.3 ∼ 0.9) × 1012/cm2. No obvious twin was observed in the HAZ under the condition of normal weld heat input. By controlling weld heat input ($E \\leq$ 20 kJ/cm), the impact toughness in the HAZ can be assured.

  16. A Low Collision and High Throughput Data Collection Mechanism for Large-Scale Super Dense Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Chunyang Lei

    2016-07-01

    Full Text Available Super dense wireless sensor networks (WSNs have become popular with the development of Internet of Things (IoT, Machine-to-Machine (M2M communications and Vehicular-to-Vehicular (V2V networks. While highly-dense wireless networks provide efficient and sustainable solutions to collect precise environmental information, a new channel access scheme is needed to solve the channel collision problem caused by the large number of competing nodes accessing the channel simultaneously. In this paper, we propose a space-time random access method based on a directional data transmission strategy, by which collisions in the wireless channel are significantly decreased and channel utility efficiency is greatly enhanced. Simulation results show that our proposed method can decrease the packet loss rate to less than 2 % in large scale WSNs and in comparison with other channel access schemes for WSNs, the average network throughput can be doubled.

  17. A numerical study of super-resolution through fast 3D wideband algorithm for scattering in highly-heterogeneous media

    KAUST Repository

    Létourneau, Pierre-David

    2016-09-19

    We present a wideband fast algorithm capable of accurately computing the full numerical solution of the problem of acoustic scattering of waves by multiple finite-sized bodies such as spherical scatterers in three dimensions. By full solution, we mean that no assumption (e.g. Rayleigh scattering, geometrical optics, weak scattering, Born single scattering, etc.) is necessary regarding the properties of the scatterers, their distribution or the background medium. The algorithm is also fast in the sense that it scales linearly with the number of unknowns. We use this algorithm to study the phenomenon of super-resolution in time-reversal refocusing in highly-scattering media recently observed experimentally (Lemoult et al., 2011), and provide numerical arguments towards the fact that such a phenomenon can be explained through a homogenization theory.

  18. A Low Collision and High Throughput Data Collection Mechanism for Large-Scale Super Dense Wireless Sensor Networks

    Science.gov (United States)

    Lei, Chunyang; Bie, Hongxia; Fang, Gengfa; Gaura, Elena; Brusey, James; Zhang, Xuekun; Dutkiewicz, Eryk

    2016-01-01

    Super dense wireless sensor networks (WSNs) have become popular with the development of Internet of Things (IoT), Machine-to-Machine (M2M) communications and Vehicular-to-Vehicular (V2V) networks. While highly-dense wireless networks provide efficient and sustainable solutions to collect precise environmental information, a new channel access scheme is needed to solve the channel collision problem caused by the large number of competing nodes accessing the channel simultaneously. In this paper, we propose a space-time random access method based on a directional data transmission strategy, by which collisions in the wireless channel are significantly decreased and channel utility efficiency is greatly enhanced. Simulation results show that our proposed method can decrease the packet loss rate to less than 2% in large scale WSNs and in comparison with other channel access schemes for WSNs, the average network throughput can be doubled. PMID:27438839

  19. A Low Collision and High Throughput Data Collection Mechanism for Large-Scale Super Dense Wireless Sensor Networks.

    Science.gov (United States)

    Lei, Chunyang; Bie, Hongxia; Fang, Gengfa; Gaura, Elena; Brusey, James; Zhang, Xuekun; Dutkiewicz, Eryk

    2016-07-18

    Super dense wireless sensor networks (WSNs) have become popular with the development of Internet of Things (IoT), Machine-to-Machine (M2M) communications and Vehicular-to-Vehicular (V2V) networks. While highly-dense wireless networks provide efficient and sustainable solutions to collect precise environmental information, a new channel access scheme is needed to solve the channel collision problem caused by the large number of competing nodes accessing the channel simultaneously. In this paper, we propose a space-time random access method based on a directional data transmission strategy, by which collisions in the wireless channel are significantly decreased and channel utility efficiency is greatly enhanced. Simulation results show that our proposed method can decrease the packet loss rate to less than 2 % in large scale WSNs and in comparison with other channel access schemes for WSNs, the average network throughput can be doubled.

  20. Photochemical properties in flag leaves of a super-high-yielding hybrid rice and a traditional hybrid rice (Oryza sativa L.) probed by chlorophyll a fluorescence transient.

    Science.gov (United States)

    Zhang, Meiping; Shan, YongJie; Kochian, Leon; Strasser, Reto J; Chen, GuoXiang

    2015-12-01

    Chlorophyll a fluorescence of flag leaves in a super-high-yielding hybrid rice (Oryza sativa L.) LYPJ, and a traditional hybrid rice SY63 cultivar with lower grain yield, which were grown in the field, were investigated from emergence through senescence of flag leaves. As the flag leaf matured, there was an increasing trend in photosynthetic parameters such as quantum efficiency of primary photochemistry ([Formula: see text] Po) and efficiency of electron transport from PS II to PS I (Ψ Eo). The overall photosynthetic performance index (PIABS) was significantly higher in the high-yielding LYPJ compared to SY63 during the entire reproductive stage of the plant, the same to MDA content. However, [Formula: see text] Po(=F V/F M), an indicator of the primary photochemistry of the flag leaf, did not display significant changes with leaf age and was not significantly different between the two cultivars, suggesting that PIABS is a more sensitive parameter than [Formula: see text] Po (=F V/F M) during leaf age for distinguishing between cultivars differing in yield.

  1. SuperQuant

    DEFF Research Database (Denmark)

    Gorshkov, Vladimir; Verano-Braga, Thiago; Kjeldsen, Frank

    2015-01-01

    SuperQuant is a quantitative proteomics data processing approach that uses complementary fragment ions to identify multiple co-isolated peptides in tandem mass spectra allowing for their quantification. This approach can be applied to any shotgun proteomics data set acquired with high mass accura...... of the same proteins were close to the values typical for other precursor ion-based quantification methods. The raw data is deposited to ProteomeXchange (PXD001907). The developed node is available for testing at https://github.com/caetera/SuperQuantNode....

  2. High-Sensitivity GaN Microchemical Sensors

    Science.gov (United States)

    Son, Kyung-ah; Yang, Baohua; Liao, Anna; Moon, Jeongsun; Prokopuk, Nicholas

    2009-01-01

    Systematic studies have been performed on the sensitivity of GaN HEMT (high electron mobility transistor) sensors using various gate electrode designs and operational parameters. The results here show that a higher sensitivity can be achieved with a larger W/L ratio (W = gate width, L = gate length) at a given D (D = source-drain distance), and multi-finger gate electrodes offer a higher sensitivity than a one-finger gate electrode. In terms of operating conditions, sensor sensitivity is strongly dependent on transconductance of the sensor. The highest sensitivity can be achieved at the gate voltage where the slope of the transconductance curve is the largest. This work provides critical information about how the gate electrode of a GaN HEMT, which has been identified as the most sensitive among GaN microsensors, needs to be designed, and what operation parameters should be used for high sensitivity detection.

  3. High-Speed Imaging of a Water Droplet Impacting a Super Cold Surface

    KAUST Repository

    Khaled, Narimane

    2016-08-01

    Frost formation is of a major research interest as it can affect many industrial processes. Frost appears as a thin deposit of ice crystals when the temperature of the surface is below the freezing point of the liquid. The objective of this research is to study icing with hope to propose new anti-icing and deicing methods. In the beginning of the research, cracking of the ice layer was observed when a deionized water droplet impacts a ?50 oC cooled sphere surface that is in contact with dry ice. To further investigate the cracks occurrence, multiple experiments were conducted. It was observed that the sphere surface temperature and droplet temperature (ranges from 10-80 oC) have no effect on the crack formation. On the other hand, it was observed that formation of a thin layer of frost on the sphere before the drop impact leads the lateral cracking of the ice. Thus, attempts to reproduce the cracks on clean super cold sphere surfaces were made using scratched and sandblasted spheres as well as superhydrophobized and polymer particle coated spheres. Furthermore, innovative methods were tried to initiate the cracks by placing epoxy glue bumps and ice-islands coatings on the surface of the spheres. All of these attempts to reproduce the crack formation without the presence of frost, failed. Nonetheless, the adding of isolated frost on the sphere surfaces always leads to the crack formation. Generally, frost forms on the small spheres faster than it does on the bigger ones. Additionally, the cold water droplet produces thicker water and ice layer compared to a hot water droplet; and the smaller the sphere the larger its water and ice layer thicknesses.

  4. Triggers for a high sensitivity charm experiment

    Energy Technology Data Exchange (ETDEWEB)

    Christian, D.C.

    1994-07-01

    Any future charm experiment clearly should implement an E{sub T} trigger and a {mu} trigger. In order to reach the 10{sup 8} reconstructed charm level for hadronic final states, a high quality vertex trigger will almost certainly also be necessary. The best hope for the development of an offline quality vertex trigger lies in further development of the ideas of data-driven processing pioneered by the Nevis/U. Mass. group.

  5. Scalloped electrodes for highly sensitive electrical measurements

    DEFF Research Database (Denmark)

    Vazquez Rodriguez, Patricia; Dimaki, Maria; Svendsen, Winnie Edith

    2011-01-01

    In this work we introduce a novel out-of-plane electrode with pronounced scalloped surface and high aspect ratio for electrical recordings of brain tissue in vitro, with the aim to reduce significantly the impedance of the measuring system. The profile and height of the structures is tailored...... by means of silicon fabrication techniques that sharpen them progressively and in a controlled manner. We will show that the use of the scalloped area achieves a great decrease in impedance, which is very significant for a reduction of noise in electrical measurements. The measured impedance reflects...

  6. Ultrasonic assisted rapid synthesis of high uniform super-paramagnetic microspheres with core-shell structure and robust magneto-chromatic ability

    Science.gov (United States)

    Zhang, Wenyan; Chen, Jiahua; Wang, Wei; Lu, GongXuan; Hao, Lingyun; Ni, Yaru; Lu, Chunhua; Xu, Zhongzi

    2017-03-01

    Super-paramagnetic core-shell microspheres were synthesized by ultrasonic assisted routine under low ultrasonic irradiation powers. Compared with conventional routine, ultrasonic effect could not only improve the uniformity of the core-shell structure of Fe3O4@SiO2, but shorten the synthesis time in large scale. Owing to their hydrophilicity and high surface charge, the Fe3O4@SiO2 microspheres could be dispersed well in distilled water to form homogeneous colloidal suspension. The suspensions have favorable magneto-chromatic ability that they sensitively exhibit brilliant colorful ribbons by magnetic attraction. The colorful ribbons, which distributed along the magnetic lines, make morphology of the magnetic fields become "visible" to naked eyed. Those colorful ribbons originate from strong magnetic interaction between the microspheres and magnetic fields. Furthermore, the magneto-chromatic performance is reversible as the colorful ribbons vanished rapidly with the removing of magnetic fields. The silica layer effectively enhanced the acid resistance and surface-oxidation resistance of theFe3O4@SiO2 microspheres, so they could exhibit stable magnetic nature and robust magneto-chromatic property in acid environment.

  7. Laneway's Side Stability Mechanism and Support Technology in Super-high Roadway%巨高巷道巷帮稳定机理及支护技术

    Institute of Scientific and Technical Information of China (English)

    李积星; 许磊; 蒋红军

    2012-01-01

    以山西某矿5203轨道巷的巨高巷道为研究对象,采用对比分析方法,描述了巨高巷道巷帮水平位移和下沉特征及塑性区的分布特征。通过分析巷帮片帮力学模型、巷帮锚固墙的对深部围岩约束原理、巨高巷道金属支架腿部易产生压杆失稳等,最终采用高强锚杆、带、网、索支护方式加固巷帮并确定了合理支护参数。实践结果表明,巨高巷道巷帮稳定原理适用于巨高巷道巷帮支护。%Taking super-high roadway appeared in 5203 track roadway in a mine of Shanxi as research object.The horizontal displacement,subsidence features and plastic zone distribution characteristics of laneway's side in super-high roadway are described with comparison analysis method in this paper.Through analyzing mechanical model of rib spalling,constraint theory of anchor wall of laneway's side on deep surrounding rock and pressure bar destabilization of metallic support generated in steel timber leg of super-high roadway,finally,the support form of using high strength bolts,steel strip,anchor net and anchor cable to reinforce laneway's side is adopted,and the reasonable supporting parameters are determined.The result of engineering practice proves that the laneway's side stabilization theory of super-high roadway is suitable to the laneway's side support of super-high roadside.

  8. Multipurpose High Sensitivity Radiation Detector: Terradex

    Energy Technology Data Exchange (ETDEWEB)

    Alpat, Behcet [Dipartimento di Fisica dell' Universita di Perugia and INFN Sezione di Perugia (Italy)]. E-mail: behcet.alpat@pg.infn.it; Aisa, Damiano [Dipartimento di Fisica dell' Universita di Perugia and INFN Sezione di Perugia (Italy); Bizzarri, Marco [Dipartimento di Fisica dell' Universita di Perugia and INFN Sezione di Perugia (Italy); Blasko, Sandor [Dipartimento di Fisica dell' Universita di Perugia and INFN Sezione di Perugia (Italy); Esposito, Gennaro [Dipartimento di Fisica dell' Universita di Perugia and INFN Sezione di Perugia (Italy); Farnesini, Lucio [Dipartimento di Fisica dell' Universita di Perugia and INFN Sezione di Perugia (Italy); Fiori, Emmanuel [Dipartimento di Fisica dell' Universita di Perugia and INFN Sezione di Perugia (Italy); Papi, Andrea [Dipartimento di Fisica dell' Universita di Perugia and INFN Sezione di Perugia (Italy); Postolache, Vasile [Dipartimento di Fisica dell' Universita di Perugia and INFN Sezione di Perugia (Italy); Renzi, Francesca [Dipartimento di Fisica dell' Universita di Perugia and INFN Sezione di Perugia (Italy); Ionica, Romeo [Politecnica University of Bucarest, Splaiul Indipendentei, Bucharest (Romania); Manolescu, Florentina [Space Science Institute of Bucharest, Maugurele, Bucharest (Romania); Ozkorucuklu, Suat [Suleyman Demirel Universitesi, Isparta (Turkey); Denizli, Haluk [Abant Izzet Baysal Universitesi, Bolu (Turkey); Tapan, Ilhan [Uludag Universitesi, Bursa (Turkey); Ercan Pilicer [Uludag Universitesi, Bursa (Turkey); Egidi, Felice [SITE Technology, Carsoli (Italy); Moretti, Cesare [SITE Technology, Carsoli(AQ) (Italy); Dicola, Luca [SITE Technology, Carsoli(AQ) (Italy)

    2007-05-11

    Terradex project aims to realise an accurate and programmable multiparametric tool which will measure relevant physical quantities such as observation time, energy and type of all decay products of three naturally occurring decay chains of uranium and thorium series present in nature as well as the decay products of man-made radioactivity. The measurements described in this work are based on the performance tests of the first version of an instrument that is designed to provide high counting accuracy, by introducing self-triggering, delayed time-coincidence technique, of products of a given decay chain. In order to qualify the technique and to calibrate the Terradex, a {sup 222}Rn source is used. The continuous and accurate monitoring of radon concentration in air is realised by observing the alpha and beta particles produced by the decay of {sup 222}Rn and its daughters and tag each of them with a precise occurrence time. The validity of delayed coincident technique by using the state of the art electronics with application of novel data sampling and analysis methods are discussed. The flexibility of sampling protocols and the advantages of online calibration capability to achieve the highest level of precision in natural and man-made radiation measurements are also described.

  9. Technological development for super-high efficiency solar cells. Technological development for super-high efficiency singlecrystalline silicon solar cells (super-high efficiency singlecrystalline Si solar cells); Chokokoritsu taiyo denchi no gijutsu kaihatsu. Chokokoritsu tankessho silicon taiyo denchi no gijutsu kaihatsu (chokokoritsu tankessho silicon taiyo denchi cell no gijutsu kaihatsu)

    Energy Technology Data Exchange (ETDEWEB)

    Tatsuta, M. [New Energy and Industrial Technology Development Organization, Tokyo (Japan)

    1994-12-01

    This paper reports the study results on technological development of super-high efficiency singlecrystalline silicon solar cells in fiscal 1994. (1) On development of high-performance light receiving layer, the fine electrode for receiving surfaces was designed to reduce serial resistance, and the high-quality oxide passivation film was studied to reduce surface recombination velocity. (2) On development of forming technology of back heterojunction, the high-quality cell with B-doped fine crystalline Si film on its back was studied by heat treatment of the fine crystalline Si film, and the cell structure with high back reflectance of light was also studied. (3) On analysis for high-efficiency cells, the relation between the back recombination velocity at the interface between p-type substrate and back passivation film, and the internal collection efficiency as probe light was injected from the back, was calculated by numerical simulation. As a result, the cell back recombination velocity could be evaluated by measuring the spectral internal collection efficiency to back injection. 15 figs., 6 tabs.

  10. Matter Composition and Two Stage Evolution of a Liangshan Super High-Sulfur Coal Seam in Kaili, Eastern Guizhou

    Institute of Scientific and Technical Information of China (English)

    YI Tong-sheng; QIN Yong; ZHANG Jing; WU Yan-yan; LI Zhuang-fu

    2007-01-01

    Super-high sulfur coal resultes in serious coal-derived pollution but might have a particular genesis. Thus, a columnar section of an Early Permian Liangshan Formation coal seam. weight average sulfur content 5.80%, from Kaili, eastern Guizhou, was studied using the methods of coal petrology and geochemistry. The results show that the seam was apparently formed in seawater-effected peat bogs that developed in two distinct stages. During the first stage various layers were formed in a supratidal bog and have a composition characteristic of a bog with a gradually decreasing seawater effect, decreasing water dynamics, and an increasingly reductive environment. Layers in the upper seam formed during a second stage in an intertidal bog. These layers are very high in total and inorganic sulfur, the ratios of organic/inorganic sulfur and V/I drop, they are high in coal ash yield and have a high ash component index, considerable barkinite, oxidized and detrital macerals, have a porphyroclatic micro-structure and are rich in pyrite, all of which indicate the coal-forming environment had higher oxidation potential, strong and roiling water dynamics, and intermittent exposure to a sulfur rich environment.

  11. The Super Patalan Numbers

    OpenAIRE

    Richardson, Thomas M.

    2014-01-01

    We introduce the super Patalan numbers, a generalization of the super Catalan numbers in the sense of Gessel, and prove a number of properties analagous to those of the super Catalan numbers. The super Patalan numbers generalize the super Catalan numbers similarly to how the Patalan numbers generalize the Catalan numbers.

  12. Super-high-frequency shielding properties of excimer-laser-synthesized-single-wall-carbon-nanotubes/polyurethane nanocomposite films

    Science.gov (United States)

    Aïssa, B.; Laberge, L. L.; Habib, M. A.; Denidni, T. A.; Therriault, D.; El Khakani, M. A.

    2011-04-01

    Electromagnetic shielding attenuation (ESA) properties of carbon nanotubes/polymer nanocomposite films, in the super high frequency (SHF) X-band (7-12 GHz) domain are studied. The nanocomposite films consisted of thermoset polyurethane (PU) resin blended with single-walled carbon nanotubes (SWCNTs) mats, and deposited on fused quartz substrates. Two different approaches were used to achieve the nanocomposite films, namely (i) through the on-substrate "all-laser" growth approach of SWCNTs directly onto substrate, followed by their infiltration by the PU resin, and (ii) by appropriately dispersing the chemically-purified SWCNTs (in the soot form) into the PU matrix and their subsequent deposition onto quartz substrates by means of a solvent casting process. Characterizations of the ESA properties of the developed nanocomposite films show that they exhibit systematically a deep shielding band, centered at around 9.5 GHz, with an attenuation as high as |- 30| dB, recorded for SWCNT loads of 2.5 wt. % and above. A direct correlation is established between the electrical conductivity of the nanocomposite films and their electromagnetic shielding capacity. The SWCNTs/PU nanocomposites developed here are highly promising shielding materials as SHF notch filters, as their ESA capacity largely exceeds the target value of |- 20| dB generally requested for commercial applications.

  13. A theoretical prediction of super high-performance thermoelectric materials based on MoS2/WS2 hybrid nanoribbons.

    Science.gov (United States)

    Zhang, Zhongwei; Xie, Yuee; Peng, Qing; Chen, Yuanping

    2016-02-17

    Modern society is hungry for electrical power. To improve the efficiency of energy harvesting from heat, extensive efforts seek high-performance thermoelectric materials that possess large differences between electronic and thermal conductance. Here we report a super high-performance material of consisting of MoS2/WS2 hybrid nanoribbons discovered from a theoretical investigation using nonequilibrium Green's function methods combined with first-principles calculations and molecular dynamics simulations. The hybrid nanoribbons show higher efficiency of energy conversion than the MoS2 and WS2 nanoribbons due to the fact that the MoS2/WS2 interface reduces lattice thermal conductivity more than the electron transport. By tuning the number of the MoS2/WS2 interfaces, a figure of merit ZT as high as 5.5 is achieved at a temperature of 600 K. Our results imply that the MoS2/WS2 hybrid nanoribbons have promising applications in thermal energy harvesting.

  14. Design optimization of high pressure and high temperature piezoresistive pressure sensor for high sensitivity

    Science.gov (United States)

    Niu, Zhe; Zhao, Yulong; Tian, Bian

    2014-01-01

    This paper describes a design method for optimizing sensitivity of piezoresistive pressure sensor in high-pressure and high-temperature environment. In order to prove the method, a piezoresistive pressure sensor (HPTSS) is designed. With the purpose of increasing sensitivity and to improve the measurement range, the piezoresistive sensor adopts rectangular membrane and thick film structure. The configuration of piezoresistors is arranged according to the characteristic of the rectangular membrane. The structure and configuration of the sensor chip are analyzed theoretically and simulated by the finite element method. This design enables the sensor chip to operate in high pressure condition (such as 150 MPa) with a high sensitivity and accuracy. The silicon on insulator wafer is selected to guarantee the thermo stability of the sensor chip. In order to optimize the fabrication and improve the yield of production, an electric conduction step is devised. Series of experiments demonstrates a favorable linearity of 0.13% and a high accuracy of 0.48%. And the sensitivity of HTPSS is about six times as high as a conventional square-membrane sensor chip in the experiment. Compared with the square-membrane pressure sensor and current production, the strength of HPTTS lies in sensitivity and measurement. The performance of the HPTSS indicates that it could be an ideal candidate for high-pressure and high-temperature sensing in real application.

  15. Design optimization of high pressure and high temperature piezoresistive pressure sensor for high sensitivity.

    Science.gov (United States)

    Niu, Zhe; Zhao, Yulong; Tian, Bian

    2014-01-01

    This paper describes a design method for optimizing sensitivity of piezoresistive pressure sensor in high-pressure and high-temperature environment. In order to prove the method, a piezoresistive pressure sensor (HPTSS) is designed. With the purpose of increasing sensitivity and to improve the measurement range, the piezoresistive sensor adopts rectangular membrane and thick film structure. The configuration of piezoresistors is arranged according to the characteristic of the rectangular membrane. The structure and configuration of the sensor chip are analyzed theoretically and simulated by the finite element method. This design enables the sensor chip to operate in high pressure condition (such as 150 MPa) with a high sensitivity and accuracy. The silicon on insulator wafer is selected to guarantee the thermo stability of the sensor chip. In order to optimize the fabrication and improve the yield of production, an electric conduction step is devised. Series of experiments demonstrates a favorable linearity of 0.13% and a high accuracy of 0.48%. And the sensitivity of HTPSS is about six times as high as a conventional square-membrane sensor chip in the experiment. Compared with the square-membrane pressure sensor and current production, the strength of HPTTS lies in sensitivity and measurement. The performance of the HPTSS indicates that it could be an ideal candidate for high-pressure and high-temperature sensing in real application.

  16. What's So Super about Superfoods?

    Science.gov (United States)

    ... with meals. The Skinny on Common Super Foods Salmon is a fatty fish that’s low in saturated ... soy nuts are high in polyunsaturated fat, fiber, vitamins and minerals but low in saturated fat. They ...

  17. A highly sensitive colorimetric and ratiometric sensor for fluoride ion

    Institute of Scientific and Technical Information of China (English)

    Zhao Wu Xu; Jin Tang; He Tian

    2008-01-01

    A new benzoimidazole-naphthalimide derivative 4 was synthesized and its photophysical properties were studied.This compound showed highly selectively and sensitive colorimetric and ratiometric sensing ability for fluoride anion.

  18. Fabrication of highly catalytic silver nanoclusters/graphene oxide nanocomposite as nanotag for sensitive electrochemical immunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jiamian; Wang, Xiuyun; Wu, Shuo, E-mail: wushuo@dlut.edu.cn; Song, Jie; Zhao, Yanqiu; Ge, Yanqiu; Meng, Changgong

    2016-02-04

    Silver nanoclusters and graphene oxide nanocomposite (AgNCs/GRO) is synthesized and functionalized with detection antibody for highly sensitive electrochemical sensing of carcinoembryonic antigen (CEA), a model tumor marker involved in many cancers. AgNCs with large surface area and abundant amount of low-coordinated sites are synthesized with DNA as template and exhibit high catalytic activity towards the electrochemical reduction of H{sub 2}O{sub 2}. GRO is employed to assemble with AgNCs because it has large specific surface area, super electronic conductivity and strong π-π stacking interaction with the hydrophobic bases of DNA, which can further improve the catalytic ability of the AgNCs. Using AgNCs/GRO as signal amplification tag, an enzyme-free electrochemical immunosensing protocol is designed for the highly sensitive detection of CEA on the capture antibody functionalized immunosensing interface. Under optimal conditions, the designed immunosensor exhibits a wide linear range from 0.1 pg mL{sup −1} to 100 ng mL{sup −1} and a low limit of detection of 0.037 pg mL{sup −1}. Practical sample analysis reveals the sensor has good accuracy and reproducibility, indicating the great application prospective of the AgNCs/GRO in fabricating highly sensitive immunosensors, which can be extended to the detection of various kinds of low abundance disease related proteins. - Highlights: • An enzyme-free electrochemical immunosensor is reported for detecting proteins. • A silver nanocluster/graphene oxide composite is synthesized as nanotag. • The nanotags exhibit highly catalytic activity to the electro-reduction of H{sub 2}O{sub 2}. • The as-fabricated immunosensor could detect protein in serum samples.

  19. Development of ultra-super sensitive immunohistochemistry and its application to the etiological study of adult T-cell leukemia/lymphoma.

    Science.gov (United States)

    Hasui, Kazuhisa; Wang, Jia; Tanaka, Yuetsu; Izumo, Shuji; Eizuru, Yoshito; Matsuyama, Takami

    2012-04-26

    Antigen retrieval (AR) and ultra-super sensitive immunohistochemistry (ultra-IHC) have been established for application to archival human pathology specimens. The original ultra-IHC was the ImmunoMax method or the catalyzed signal amplification system (ImmunoMax/CSA method), comprising the streptavidin-biotin complex (sABC) method and catalyzed reporter deposition (CARD) reaction with visualization of its deposition. By introducing procedures to diminish non-specific staining in the original ultra-IHC method, we developed the modified ImmunoMax/CSA method with AR heating sections in an AR solution (heating-AR). The heating-AR and modified ImmunoMax/CSA method visualized expression of the predominantly simple present form of HTLV-1 proviral DNA pX region p40Tax protein (Tax) in adult T-cell leukemia/lymphoma (ATLL) cells in archival pathology specimens in approximately 75% of cases. The simple present form of Tax detected exhibited a close relation with ATLL cell proliferation. We also established a new simplified CSA (nsCSA) system by replacing the sABC method with the secondary antibody- and horse radish peroxidase-labeled polymer reagent method, introducing the pretreatments blocking non-specific binding of secondary antibody reagent, and diminishing the diffusion of deposition in the CARD reaction. Combined with AR treating sections with proteinase K solution (enzymatic-AR), the nsCSA system visualized granular immunostaining of the complex present form of Tax in a small number of ATLL cells in most cases, presenting the possibility of etiological pathological diagnosis of ATLL and suggesting that the complex present form of Tax-positive ATLL cells were young cells derived from ATLL stem cells. The heating-AR and ultra-IHC detected physiological expression of the p53 protein and its probable phosphorylation by Tax in peripheral blood mononuclear cells of peripheral blood tissue specimens from HTLV-1 carriers, as well as physiological and pathological expression

  20. High Solids Consolidated Incinerator Facility (CIF) Wastes Stabilization with Ceramicrete and Super Cement

    Energy Technology Data Exchange (ETDEWEB)

    Walker, B.W.

    1999-09-14

    High Solids ash and scrubber solution waste streams were generated at the incinerator facility at SRS by burning radioactive diatomaceous filter rolls which contained small amounts of uranium, and listed solvents (F and U). This report details solidification activities using selected Mixed Waste Focus Area (MWFA) technologies with the High Solids waste streams.

  1. Multi-photon resonance enhanced super high-order harmonic generation

    Institute of Scientific and Technical Information of China (English)

    Lin Zheng-Zhe; Zhuang Jun; Ning Xi-Jing

    2010-01-01

    This paper proposes highly charged ions pumped by intense laser to produce very high order harmonics.Numerical simulations and full quantum theory of Ne9+ ions driven by laser pulses at 1064 nm in the power range of 109 W/cm2 ~ 1015 W/cm2 show that the emission spectrum corresponds to the electronic transitions from the excited states to the ground state,which is very different from the spectrum of general high-order harmonic generation.In such situation,harmonic order as high as 1000 can be obtained without producing lower order harmonics and the energy conversion efficiency is close to general high order harmonic generation of hydrogen atom in the same laser field.

  2. Estimates of Climate Change Impact on River Discharge in Japan Based on a Super-High-Resolution Climate Model

    Directory of Open Access Journals (Sweden)

    Yoshinobu Sato

    2012-01-01

    Full Text Available The impact of climate change on river discharge was assessed by hydrological simulations for several major river basins in Japan using the latest version of a super-high-resolution atmospheric general circulation model (AGCM with a horizontal resolution of about 20 km. Projections were made using two different datasets, one representing the present climate (1980 - 1999 and the other representing the end of the 21st century (2080 - 2099 assuming the SRES A1B scenario. River discharge was estimated by a distributed hydrological model calibrated against observed river discharge in advance. The results showed that even if the amount of precipitation does not change much in the future, river discharge will change significantly because of the increase in rainfall, decrease in snowmelt, and increase in evapotranspiration with higher air temperature. The impact of climate change on river discharge will be more significant in the northern part of Japan, especially in the Tohoku and Hokuriku regions. In these regions, the monthly average river discharge at the end of the 21st century was projected to be more than 200% higher in February and approximately 50 - 60% lower in May compared with the present flow. These results imply that the increase in air temperature has important consequences for the hydrological cycle, particularly in regions where the water supply is currently dominated by snowmelt.

  3. Overview of high-Q2 nucleon form factor program with Super BigBite Spectrometer in JLab's Hall A

    Science.gov (United States)

    Puckett, Andrew; Jefferson Lab Hall A; Super BigBite Spectrometer Collaboration

    2017-01-01

    The elastic electromagnetic form factors (EMFFs) of the nucleon describe the impact-parameter-space distributions of electric charge and magnetization in the nucleon in the infinite momentum frame. The form factors are among the simplest and most fundamental measurable dynamical quantities describing the nucleon's structure. Precision measurements of the nucleon form factors provide stringent benchmarks testing the most sophisticated theoretical models of the nucleon, as well as ab initio calculations in lattice QCD and continuum non-perturbative QCD calculations based on the Dyson-Schwinger equations. Measurements at momentum transfers Q in the few-GeV range probe the theoretically challenging region of transition between the non-perturbative and perturbative regimes of QCD. The recent upgrade of the Continuous Electron Beam Accelerator Facility (CEBAF) to a maximum electron beam energy of 11 GeV will facilitate the measurement of the nucleon helicity-conserving (F1) and helicity-flip (F2) form factors of both proton and neutron to Q2 > 10 GeV2, In this talk, I will present an overview of the Super BigBite Spectrometer, currently under construction in CEBAF's experimental Hall A, and its physics program of high-Q2 nucleon EMFF measurements. Supported by US DOE award DE-SC0014230.

  4. Comparative Study on Super Fine Mesophase Powder and MCMB Used to Manufacture High-Density Isotropic Carbon Bulks

    Institute of Scientific and Technical Information of China (English)

    LI Tong-qi; HU Zi-jun; WANG Jun-shan; GUO Yu-ming; WANG Cheng-yang

    2006-01-01

    Mesocarbon microbeads (MCMB) and super fine mesophase powder (SFMP) were prepared firstly from a coal tar pitch and then hot-condensed into high-density isotropic carbon (HDIC) bulks under 160 Mpa and finally sintered at 1 000 ℃. By analyzing the thermogravimetric behavior of the MCMB and SFMP powders, their volume shrinkage and weight loss during sintering and the bulk density and flexural strengths of their sintered bulks, it was found that the smaller sizes and the richer β-resin contents of SFMP have facilitated formation of sintered bulks with more compact isotropic structure and higher flexural strengths than MCMB. Because of the filling and bonding effects of SFMP on MCMB bulks, addition of SFMP, albeit a little, can greatly increase the flexural strengths of sintered bulks of MCMB. However, adding MCMB, even a slight amount, into SFMP can severely impair the flexural strength of sintered bulks. This might be attributed to both the crack initiation along the boundaries between MCMB and SFMP and the formation of layered texture of MCMB sphere.

  5. Changes in Some Physiological Characteristics After Full Heading Stage in Flag Leaves of Super High-Yielding Inbred Rice

    Institute of Scientific and Technical Information of China (English)

    HUANG Min; ZOU Yingbin

    2009-01-01

    In a field experiment, rice cultivar Shanyou 63 was used as a check cuitivar to investigate the changes in activity of peroxidase and contents of malondialdehyde and soluble protein after full heading stage in flag leaves of two super high-yielding inbred rice, including Shengtai 1 and Yuxiangyouzhan. The results showed that the peroxidase activities and soluble protein contents in the leaves of the three cultivars tended to increase gradually to peak values and thereafter descended during stage after full heading. Moreover, both the peroxidase activities and soluble protein contents of Shengtai 1 and Yuxiangyouzhan peaked at 8 days after full heading, which was compared with that of Shanyou 63 at 4 days later. Meanwhile, the malondialdehyde contents in the leaves of the three cultivars increased gradually after full heading stage. In addition, activities of peroxidase and contents of malondialdehyde and soluble protein in different cultivars were various at the same time. In general, for Shengtai 1 and Yuxiangyouzhan, the peroxidase activities and soluble protein contents were higher than those of Shanyou 63, whereas the malondialdehyde contents were lower compared with that of Shanyou 63. And these features could make the senescence of leaf become later and slower and photosynthetic product was more in Shengtai 1 and Yuxiangyouzhan than that in Shanyou 63.

  6. Design and Fabrication of the Superconducting Horizontal Bend Magnet for the Super High Momentum Spectrometer at Jefferson Lab

    Energy Technology Data Exchange (ETDEWEB)

    Chouhan, Shailendra S. [Michigan State University; DeKamp, Jon [Michigan State University; Burkhart, E. E, [Michigan State University; Bierwagen, J. [Michigan State University; Song, H. [Michigan State University; Zeller, Albert F. [Michigan State University; Brindza, Paul D. [JLAB; Lassiter, Steven R. [JLAB; Fowler, Michael J. [JLAB; Sun, Qiuli (Eric) [JLAB

    2015-06-01

    A collaboration exists between NSCL and JLab to design and build JLab's Super High Momentum Spectrometer (SHMS) horizontal bend magnet that allows the bending of the 12 GeV/c particles horizontally by 3° to allow SHMS to reach angles as low as 5.5°. Two full size coils have been wound and are cold tested for both magnetic and structural properties. Each coil is built from 90 layers of single-turn SSC outer conductor cable. An initial test coil with one third the turns was fabricated to demonstrate that the unique saddle shape with fully contoured ends could be wound with Rutherford superconducting cable. Learned lessons during the trial winding were integrated into the two complete full-scale coils that are now installed in the helium vessel. The fabrication of the iron yoke, cold mass, and thermal shield is complete, and assembly of the vacuum vessel is in progress. This paper presents the process and progress along with the modified magnet design to reduce the fringe field in the primary beam region and also includes the impact of the changes on coil forces and coil restraint system.

  7. Long-Term Observation of Triplex Surgery for Cataract after Phakic 6H Implantation for Super High Myopia

    Directory of Open Access Journals (Sweden)

    Xin Liu

    2016-01-01

    Full Text Available Purpose. To analyze the safety, effectiveness, and stability of triplex surgery for phakic 6H anterior chamber phakic intraocular lens explantation and phacoemulsification with in-the-bag IOL implantation for super high myopia in long-term observations. Methods. This retrospective case series evaluated 16 eyes of 10 patients who underwent triplex surgery. Best corrected visual acuity (BCVA, endothelial cell density (ECD, and associated adverse events were evaluated. Results. The mean follow-up time after the triplex surgery was 46 ± 14 months. The mean logMAR BCVA was significantly improved after triplex surgery (P = 0.047. One eye developed endophthalmitis five days postoperatively and underwent pars plana vitrectomy (PPV. Five eyes with preoperative severe endothelial cell loss developed corneal decompensation and underwent keratoplasty at a mean time of 9.4 ± 2.6 months after the triplex surgery. One eye had graft failure and underwent a second keratoplasty. The eye developed rhegmatogenous retinal detachment and underwent PPV with silicone oil 18 months later. ECD before the triplex surgery was not significantly different compared with that at last follow-up (P = 0.495 apart from these five eyes. Three eyes (18.8% developed posterior capsule opacification. Conclusions. Triplex surgery was safe and effective for phakic 6H related complicated cataracts. Early extraction before severe ECD loss is recommended.

  8. A robotic, compact, and extremely high resolution optical spectrograph for a close-in super-Earth survey

    Science.gov (United States)

    Ge, Jian; Powell, Scott; Zhao, Bo; Varosi, Frank; Ma, Bo; Sithajan, Sirinrat; Liu, Jian; Li, Rui; Grieves, Nolan; Schofield, Sidney; Avner, Louis; Jakeman, Hali; Yoder, William A.; Gittelmacher, Jakob A.; Singer, Michael A.; Muterspaugh, Matthew; Williamson, Michael; Maxwell, J. E.

    2014-08-01

    One of the most astonishing results from the HARPS and Kepler planet surveys is the recent discovery of close-in super-Earths orbiting more than half of FGKM dwarfs. This new population of exoplanets represents the most dominant class of planetary systems known to date, is totally unpredicted by the classical core-accretion disk planet formation model. High cadence and high precision Doppler spectroscopy is the key to characterize properties of this new population and constrain planet formation models. A new robotic, compact high resolution optical spectrograph, called TOU (formerly called EXPERT-III), was commissioned at the Automatic Spectroscopic Telescope (AST) at Fairborn Observatory in Arizona in July 2013 and has produced a spectral resolution of about 100,000 and simultaneous wavelength coverage of 0.38-0.9 μm with a 4kx4k back-illuminated Fairchild CCD detector. The instrument holds a very high vacuum of 1 micro torr and about 2 mK temperature stability over a month. The early on-sky RV measurements show that this instrument is approaching a Doppler precision of 1 m/s (rms) for bright reference stars (such as Tau Ceti) with 5 min exposures and better than 3 m/s (P-V, RMS~1 m/s) daily RV stability before calibration exposures are applied. A pilot survey of 20 Vsuper-Earth systems and known RV stable stars, is being launched and every star will be observed ~100 times over ~300 days time window between this summer and next spring, following up with a full survey of ~150 V< 10 FGKM dwarfs in 2015-2017.

  9. Transplantation in highly HLA-sensitized patients: challenges and solutions

    Directory of Open Access Journals (Sweden)

    Kim IK

    2014-09-01

    Full Text Available Irene K Kim, Ashley Vo, Stanley C Jordan Transplant Immunotherapy Program, Comprehensive Transplant Center, Cedars-Sinai Medical Center, Los Angeles, CA, USA Abstract: Despite better understanding of the impact of development of the human leukocyte antigen (HLA antibody and numerous advancements in immunosuppressive therapy, the ability to successfully transplant highly sensitized patients remains a significant challenge. As the percentage of the waiting list becomes increasingly populated with highly sensitized patients, there is a growing demand for effective strategies to manage these patients. Over the past 20 years, desensitization therapies have been modified and developed, and are mainly utilized at transplant centers that have developed expertise. In addition, recognition that the highly sensitized patient population is disadvantaged on the transplant waiting list has led to recent changes in national kidney allocation policy. Furthermore, creative strategies, such as enrollment of sensitized patients into paired kidney exchange programs, have been developed to find compatible matches for these patients. The goal of this article is to address some of the specific challenges related to transplanting the highly sensitized patient at a high-volume transplant center with experience in desensitization and to review established and emerging solutions to help this patient population. Keywords: human leukocyte antigen, antibodies, desensitization, high-dose intravenous immunoglobulin, rituximab

  10. Mutagen sensitivity has high heritability: evidence from a twin study.

    Science.gov (United States)

    Wu, Xifeng; Spitz, Margaret R; Amos, Christopher I; Lin, Jie; Shao, Lina; Gu, Jian; de Andrade, Mariza; Benowitz, Neal L; Shields, Peter G; Swan, Gary E

    2006-06-15

    Despite numerous studies showing that mutagen sensitivity is a cancer predisposition factor, the heritability of mutagen sensitivity has not been clearly established. In this report, we used a classic twin study design to examine the role of genetic and environmental factors on the mutagen sensitivity phenotype. Mutagen sensitivity was measured in peripheral blood lymphocytes from 460 individuals [148 pairs of monozygotic (MZ) twins, 57 pairs of dizygotic (DZ) twins, and 50 siblings]. The intraclass correlation coefficients were all significantly higher in MZ twins than in dizygotes (DZ pairs and MZ-sibling pairs combined) for sensitivity to four different mutagen challenges. Applying biometric genetic modeling, we calculated a genetic heritability of 40.7%, 48.0%, 62.5%, and 58.8% for bleomycin, benzo[a]pyrene diol epoxide, gamma-radiation, and 4-nitroquinoline-1-oxide sensitivity, respectively. This study provides the strongest and most direct evidence that mutagen sensitivity is highly heritable, thereby validating the use of mutagen sensitivity as a cancer susceptibility factor.

  11. Super magnetic nanoparticles NiFe2O4, coated with aluminum-nickel oxide sol-gel lattices to safe, sensitive and selective purification of his-tagged proteins.

    Science.gov (United States)

    Mirahmadi-Zare, Seyede Zohreh; Allafchian, Alireza; Aboutalebi, Fatemeh; Shojaei, Pendar; Khazaie, Yahya; Dormiani, Kianoush; Lachinani, Liana; Nasr-Esfahani, Mohammad-Hossein

    2016-05-01

    Super magnetic nanoparticle NiFe2O4 with high magnetization, physical and chemical stability was introduced as a core particle which exhibits high thermal stability (>97%) during the harsh coating process. Instead of multi-stage process for coating, the magnetic nanoparticles was mineralized via one step coating by a cheap, safe, stable and recyclable alumina sol-gel lattice (from bohemite source) saturated by nickel ions. The TEM, SEM, VSM and XRD imaging and BET analysis confirmed the structural potential of NiFe2O4@NiAl2O4 core-shell magnetic nanoparticles for selective and sensitive purification of His-tagged protein, in one step. The functionality and validity of the nickel magnetic nanoparticles were attested by purification of three different bioactive His-tagged recombinant fusion proteins including hIGF-1, GM-CSF and bFGF. The bonding capacity of the nickel magnetics nanoparticles was studied by Bradford assay and was equal to 250 ± 84 μg Protein/mg MNP base on protein size. Since the metal ion leakage is the most toxicity source for purification by nickel magnetic nanoparticles, therefor the nickel leakage in purified final protein was determined by atomic absorption spectroscopy and biological activity of final purified protein was confirmed in comparison with reference. Also, in vitro cytotoxicity of nickel magnetic nanoparticles and trace metal ions were investigated by MTS assay analysis. The results confirmed that the synthesized nickel magnetic nanoparticles did not show metal ion toxicity and not affected on protein folding.

  12. Super-High Temperature Alloys and Composites from NbW-Cr Systems

    Energy Technology Data Exchange (ETDEWEB)

    Shailendra Varma

    2008-12-31

    Nickel base superalloys must be replaced if the demand for the materials continues to rise for applications beyond 1000{sup o}C which is the upper limit for such alloys at this time. There are non-metallic materials available for such high temperature applications but they all present processing difficulties because of the lack of ductility. Metallic systems can present a chance to find materials with adequate room temperature ductility. Obviously the system must contain elements with high melting points. Nb has been chosen by many investigators which has a potential of being considered as a candidate if alloyed properly. This research is exploring the Nb-W-Cr system for the possible choice of alloys to be used as a high temperature material.

  13. Investigation of Phosphate Cement-based Binder with Super High Early Strength for Repair of Concrete

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Magnesium phosphate cement-based binder (MPB) for repair of concrete was prepared by proportionally mixing over burned MgO powder (M) with NHH2PO4 powder (P) and set modifying admixtures. It is characteristic by excellent properties such as rapid setting,high strength and high bond strength to old concrete.. The study is focused on the key factors influencing the setting time and strength of MPB, the bond property of MPB to old concrete and the kinetic feature of the hydration of MPB.

  14. Observing Ultra High Energy Cosmic Particles from Space: SEUSO, the Super Extreme Universe Space Observatory Mission

    CERN Document Server

    Santangelo, Andrea

    2009-01-01

    The experimental search for ultra high energy cosmic messengers, from $E\\sim 10^{19}$ eV to beyond $E\\sim 10^{20}$ eV, at the very end of the known energy spectrum, constitutes an extraordinary opportunity to explore a largely unknown aspect of our universe. Key scientific goals are the identification of the sources of ultra high energy particles, the measurement of their spectra and the study of galactic and local intergalactic magnetic fields. Ultra high energy particles might, also, carry evidence of unknown physics or of exotic particles relics of the early universe. To meet this challenge a significant increase in the integrated exposure is required. This implies a new class of experiments with larger acceptances and good understanding of the systematic uncertainties. Space based observatories can reach the instantaneous aperture and the integrated exposure necessary to systematically explore the ultra high energy universe. In this paper, after briefly summarising the science case of the mission, we desc...

  15. Achieving sensitive, high-resolution laser spectroscopy at CRIS

    Energy Technology Data Exchange (ETDEWEB)

    Groote, R. P. de [Instituut voor Kern- en Stralingsfysica, KU Leuven (Belgium); Lynch, K. M., E-mail: kara.marie.lynch@cern.ch [EP Department, CERN, ISOLDE (Switzerland); Wilkins, S. G. [The University of Manchester, School of Physics and Astronomy (United Kingdom); Collaboration: the CRIS collaboration

    2017-11-15

    The Collinear Resonance Ionization Spectroscopy (CRIS) experiment, located at the ISOLDE facility, has recently performed high-resolution laser spectroscopy, with linewidths down to 20 MHz. In this article, we present the modifications to the beam line and the newly-installed laser systems that have made sensitive, high-resolution measurements possible. Highlights of recent experimental campaigns are presented.

  16. A highly sensitive optical detector for use in deep underwater.

    Science.gov (United States)

    Hanada, H.; Hayashino, T.; Ito, M.; Iwasaki, A.; Kawamorita, K.; Kawamoto, H.; Matsumoto, T.; Narita, S.; Takayama, T.; Tanaka, S.; Yamaguchi, A.; Aoki, T.; Mitsui, K.; Ohashi, Y.; Okada, A.; Fukawa, M.; Uehara, S.; Bolesta, J. W.; Gorham, P. W.; Kondo, S.; Learned, J. G.; Matsuno, S.; Mignard, M.; Mitiguy, R.; O'Connor, D. J.; Peterson, V. Z.; Roberts, A.; Rosen, M.; Stenger, V. J.; Takemori, D.; Wilkins, G.; Grieder, P. K. F.; Minkowski, P.; Kitamura, T.; Camerini, U.; Grogan, W.; Jaworski, M.; March, R.; Narita, T.; Nicklaus, D.

    1998-05-01

    The authors have developed an optical detector module for use in deep underwater experiments that will search for high-energy neutrinos from cosmic rays and astronomical sources. This module is sensitive to single photons, is operable under high pressure, functions automatically and is remotely controlled.

  17. Magnetic gradiometer based on a high-transition temperaturesuperconducting quantum interference device for improved sensitivity of abiosensor

    Energy Technology Data Exchange (ETDEWEB)

    Lee, SeungKyun; Myers, W.R.; Grossman, H.L.; Cho, H-M.; Chemla,Y.R.; Clarke, John

    2002-07-08

    We describe a gradiometer based on a high-transition temperature Superconducting Quantum Interference Device (SQUID) for improving the sensitivity of a SQUID-based biosensor. The first-derivative gradiometer, fabricated from a single layer of YBa{sub 2}Cu{sub 3}O{sub 7-x}, has a baseline of 480 {micro}m and a balance against uniform fields of 1 part in 150. Used in our SQUID ''microscope,'' it reduces parasitic magnetic fields generated by the measurement process to the level of the SQUID noise. The gradiometer-based microscope is two orders of magnitude more sensitive to super paramagnetic nanoparticles bound to biological targets than our earlier magnetometer-based microscope.

  18. High frequency A-type pulsators discovered using SuperWASP

    CERN Document Server

    Holdsworth, Daniel L; Gillon, M; Clubb, K I; Southworth, J; Maxted, P F L; Anderson, D R; Barros, S C C; Cameron, A Collier; Delrez, L; Faedi, F; Haswell, C A; Hellier, C; Horne, K; Jehin, E; Norton, A J; Pollacco, D; Skillen, I; Smith, A M S; West, R G; Wheatley, P J

    2014-01-01

    We present the results of a survey using the WASP archive to search for high frequency pulsations in F-, A- and B-type stars. Over 1.5 million targets have been searched for pulsations with amplitudes greater than 0.5 millimagnitude. We identify over 350 stars which pulsate with periods less than 30 min. Spectroscopic follow-up of selected targets has enabled us to confirm 10 new rapidly oscillating Ap stars, 13 pulsating Am stars and the fastest known $\\delta$ Scuti star. We also observe stars which show pulsations in both the high-frequency domain and in the low-frequency $\\delta$ Scuti range. This work shows the power of the WASP photometric survey to find variable stars with amplitudes well below the nominal photometric precision per observation.

  19. Super Continuum Generation at 1310nm in a Highly Nonlinear Photonic Crystal Fiber with a Minimum Anomalous Group Velocity Dispersion

    Directory of Open Access Journals (Sweden)

    Ashkan Ghanbari

    2014-12-01

    Full Text Available In the present study, we investigate the evolution of the super continuum generation (SCG through the triangular photonic crystal fiber (PCF at 1310nm by using both full-vector multi pole method (M.P.M and novel concrete algorithms: Symmetric Split-step Fourier (SSF and fourth order Runge Kutta(RK4 which is an accurate method to solve the general nonlinear Schrodinger equation (GNLSE. We propose an ideal solid-core PCF structure featuring a minimum anomalous group velocity dispersion (GVD, small higher order dispersions (HODs and enhanced nonlinearity for appropriate super continuum generation with low input pulse energies over discrete distances of the PCF. We also investigate the impact of the linear and nonlinear effects on the super continuum spectra in detail and compare the results with different status.

  20. Molecular Assisted Breeding and Adaptability Analysis of Zhongyouza 11 with Super High Oil Content

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Using a three-line system of Shaan 2A cytoplasmic male sterility, a hybrid variety rapeseed, Zhongyouza 11, was developed by the combination of traditional methods and a molecular marker-assisted breeding technique. This hybrid variety had high grain yield, high oil content, wide adaptability, and good quality. The oil content of Zhongyouza 11 is steadily above 43% in the three ecological regions along the Yangtze River valley, which is the largest winter oilseed production area in China. The highest oil content of Zhongyouza 11 reached 46.68% in the upper reaches of the Yangtze River valley in 2003-2004, which was the highest among all lines involved in the national regional rapeseed variety trials. In the regional yield trials in Hubei Province, the average yield of Zhongyouza 11 reached 2 853 kg ha-1 (2002-2004), yielding more than the control variety Zhongshuang 6 by 11.34%. In the national trials, the yield of Zhongyouza 11 reached 2 405.7, 2 697.3, and 2 770.2 kg ha-1 in the upper, middle, and lower reaches of the Yangtze River valley, yielding more than the control varieties by 11.52, 12.9, and 14.92%, respectively, in 2003-2005. Both the high oil content and high grain yield contributed to the high oil yield of Zhongyouza 11. The oil yield of Zhongyouza 11 in the national trials reached 1083.3, 1210.2, and 1224.8 kg ha-1, yielding more than the controls by 29.42, 27.65, and 20.98%, respectively, in the upper, middle, and lower reaches of the Yangtze River valley. The highest oil yield reached 1369.65 kg ha-1 in the middle reach of the Yangtze River valley(2003-2004), with an increase of 46.21% compared to the control. The experimental sites distributed widely along the Yangtze River valley, cover most of the Chinese winter rapeseed production areas. Among the 89 experimental location/years, the yield of Zhongyouza 11 surpassed the controls at 77 location/years in the trials, indicating its wide adaptability.Zhongyouza 11 was the only one that passed the

  1. Reliability of system identification technique in super high-rise building

    Directory of Open Access Journals (Sweden)

    Ayumi eIkeda

    2015-07-01

    Full Text Available A smart physical-parameter based system identification method has been proposed in the previous paper. This method deals with time-variant nonparametric identification of natural frequencies and modal damping ratios using ARX (Auto-Regressive eXogenous models and has been applied to high-rise buildings during the 2011 off the Pacific coast of Tohoku earthquake. In this perspective article, the current state of knowledge in this class of system identification methods is explained briefly and the reliability of this smart method is discussed through the comparison with the result by a more confident technique.

  2. Cultivar and Tree Density As Key Factors in the Long-Term Performance of Super High-Density Olive Orchards.

    Science.gov (United States)

    Díez, Concepción M; Moral, Juan; Cabello, Diego; Morello, Pablo; Rallo, Luis; Barranco, Diego

    2016-01-01

    Super high-density (SHD) olive orchards are rapidly expanding since the first plantation was set up in Spain in the 1990s. Because there are no long-term studies characterizing these systems, it is unknown if densities above a certain threshold could trigger competition among fully-grown trees, compromising their development. Over 14 years we have evaluated the performance of the major olive cultivars currently planted in SHD systems ("Arbequina," Arbequina IRTA-i·18, "Arbosana," "Fs-17," and "Koroneiki") and nine SHD designs ranging from 780 to 2254 trees ha(-1) for the cultivar "Arbequina." Remarkably, the accumulated fruit and oil production of the five cultivars increased linearly over time. Our data indicated the favorable long-term performance of the evaluated cultivars with an average annual oil production of 2.3 t ha(-1). Only "Fs-17" did not perform well to the SHD system in our conditions and it yielded about half (1.2 t ha(-1)) of the other cultivars. In the density trial for "Arbequina," both fruit and oil accumulated production increased over time as a function of tree density. Thus, the accumulated oil yield ranged from 16.1 t ha(-1) for the lowest density (780 trees ha(-1)) to 29.9 t ha(-1) for the highest (2254 trees ha(-1)). In addition, we note that the accumulated production per surface unit showed a better correlation with the hedgerow length than the tree density. Thus, the current planting designs of SHD olive orchards can be further improved taking this parameter into account. Despite observations that some irregular patterns of crop distribution have arisen, our olive hedgerows are still fully productive after 14 years of planting. This result contradicts previous experiences that showed declines in production 7 or 8 years after planting due to high vigor, shading, and limited ventilation.

  3. Research of High Sensitivity Uncooled Infrared Detector Array

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Pingchuan [Huazhong University of Science and Technology, Wuhan 430074 (China); Zhang, Bo, E-mail: redmoon123456@126.com, E-mail: lhzyzb@126.com [Luohe Vocational Technology College, Luohe 462002 (China)

    2011-02-01

    The infrared thermal imaging technology has been widely used in military and civilian fields and the field of the infrared detection and infrared thermal imaging technology has been of concern for a long time. On infrared thermal imaging, its core components for the infrared focal plane arrays, how to develop a high sensitivity of the multi-focal plane infrared detector is a key issue. Although the Common focal plane array of quantum has high sensitivity, but it requires low temperature cooling work environment and led to complexity and high cost, difficult to compact. Conventional uncooled infrared focal plane array is contrast to the quantum focal plane arrays. Therefore, this article preceded by the uncooled infrared detector array to improve the wide temperature sensitivity in examining the feasibility PMN composite film, materials composition, structure design and preparation process technology.

  4. Super-High Heat Flux Removal Using Sintered Metal Porous Media

    Institute of Scientific and Technical Information of China (English)

    Kazuhisa YUKI; Jun ABEI; Hidetoshi HASHIZUME; Saburo TODA

    2005-01-01

    Heat transfer experiments using various porous materials are performed to verify the possibility of extremely highheat flux removal (several dozens of MW/m2). The porous media introduced in this experiment are bronze particle-sintered ones and copper fibers-sintered ones that have high thermal conductivity, each of which can enhance the thermal diffusion in the porous material. From the heat transfer experiments using a non-transferredtype of plasma arcjet as a high heat flux source, the steady heat removal of 66.0 MW/m2 is proved by using the bronze porous medium whose pore size and porosity are 100 μm and 0.38, respectively. Furthermore, as the result of eveluating the heat removal performance for various copper fiber porous media with the porosity from 0.5 to 0.7 and the fiber diameter from 30 to 90 μm, it is clarified that the maximum cooling performance exceeds 70.0MW/m2 at the porosity of 0.7 and the fiber diameter of 90 μm, and that using the lower porosity material is useful for improving an evaporation rate in the porous media.

  5. High-magnification super-resolution FINCH microscopy using birefringent crystal lens interferometers

    Science.gov (United States)

    Siegel, Nisan; Lupashin, Vladimir; Storrie, Brian; Brooker, Gary

    2016-12-01

    Fresnel incoherent correlation holography (FINCH) microscopy is a promising approach for high-resolution biological imaging but has so far been limited to use with low-magnification, low-numerical-aperture configurations. We report the use of in-line incoherent interferometers made from uniaxial birefringent α-barium borate (α-BBO) or calcite crystals that overcome the aberrations and distortions present with previous implementations that employed spatial light modulators or gradient refractive index lenses. FINCH microscopy incorporating these birefringent elements and high-numerical-aperture oil immersion objectives could outperform standard wide-field fluorescence microscopy, with, for example, a 149 nm lateral point spread function at a wavelength of 590 nm. Enhanced resolution was confirmed with sub-resolution fluorescent beads. Taking the Golgi apparatus as a biological example, three different proteins labelled with GFP and two other fluorescent dyes in HeLa cells were resolved with an image quality that is comparable to similar samples captured by structured illumination microscopy.

  6. Super-aperture metrology: overcoming a fundamental limit in imaging smooth highly curved surfaces.

    Science.gov (United States)

    Liu, J; Liu, C; Tan, J; Yang, B; Wilson, T

    2016-03-01

    The imaging of smooth, highly curved or tilted surfaces is widely recognized as one of the most challenging and unsolved problems in optical imaging and metrology today. The reason is that even when such surfaces are imaged using high aperture microscope objectives the steepness of the features causes the light to be reflected in such a way that it is not captured by the lens. This is true even in the limiting case of unity numerical aperture since the illuminating light may also be reflected in the forward direction. In order to overcome this fundamental problem we have developed a method whereby such specimens are covered with a readily removable organic fluorescent film thereby creating an isotropic scattering surface. We show that we are readily able to detect slopes with angles close 90° using a 0.75 NA objective--an 82% improvement over the theoretical aperture limit. Issues of variation in film thickness deposition are shown to be readily accommodated. This approach may be used with other fluorophore materials, organic or inorganic, since there is no need for biocompatibility in this application.

  7. Super-sparse principal component analyses for high-throughput genomic data

    Directory of Open Access Journals (Sweden)

    Lee Youngjo

    2010-06-01

    Full Text Available Abstract Background Principal component analysis (PCA has gained popularity as a method for the analysis of high-dimensional genomic data. However, it is often difficult to interpret the results because the principal components are linear combinations of all variables, and the coefficients (loadings are typically nonzero. These nonzero values also reflect poor estimation of the true vector loadings; for example, for gene expression data, biologically we expect only a portion of the genes to be expressed in any tissue, and an even smaller fraction to be involved in a particular process. Sparse PCA methods have recently been introduced for reducing the number of nonzero coefficients, but these existing methods are not satisfactory for high-dimensional data applications because they still give too many nonzero coefficients. Results Here we propose a new PCA method that uses two innovations to produce an extremely sparse loading vector: (i a random-effect model on the loadings that leads to an unbounded penalty at the origin and (ii shrinkage of the singular values obtained from the singular value decomposition of the data matrix. We develop a stable computing algorithm by modifying nonlinear iterative partial least square (NIPALS algorithm, and illustrate the method with an analysis of the NCI cancer dataset that contains 21,225 genes. Conclusions The new method has better performance than several existing methods, particularly in the estimation of the loading vectors.

  8. Unexpected generation of super-high energetic electrons at relativistic circularly polarized laser-solid interactions in the presence of large scale pre-plasmas

    CERN Document Server

    Wu, D; Luan, S X; Yu, W

    2015-01-01

    As a continuation of the previous work "Identifying the source of super-high energetic electrons in the presence of pre-plasma in laser-matter interaction at relativistic intensities [arXiv: 1512.02411]", we have investigated the role of circularly polarized (CP) laser pulses while keeping other conditions the same. It is found that in the presence of large scale pre-formed plasmas, super-high energetic electrons can be generated at relativistic CP laser-solid interactions. For laser of intensity 10$^{20}\\ $W$/$cm$^2$ and pre-plasma scale-length 10$\\ \\mu$m, the cut-off energy of electron by CP laser is 120$\\ $MeV compared with 100$\\ $MeV in the case of linearly polarized (LP) laser. The unexpected super-high energetic electron acceleration can also be explained by the two-stage acceleration model, by considering the polarization transition of the reflected laser from CP to elliptically polarized (EP). The polarization state transition is addressed, and a modified scaling law in the presence of EP laser is obt...

  9. High resolution OCT image generation using super resolution via sparse representation

    Science.gov (United States)

    Asif, Muhammad; Akram, Muhammad Usman; Hassan, Taimur; Shaukat, Arslan; Waqar, Razi

    2017-02-01

    In this paper we propose a technique for obtaining a high resolution (HR) image from a single low resolution (LR) image -using joint learning dictionary - on the basis of image statistic research. It suggests that with an appropriate choice of an over-complete dictionary, image patches can be well represented as a sparse linear combination. Medical imaging for clinical analysis and medical intervention is being used for creating visual representations of the interior of a body, as well as visual representation of the function of some organs or tissues (physiology). A number of medical imaging techniques are in use like MRI, CT scan, X-rays and Optical Coherence Tomography (OCT). OCT is one of the new technologies in medical imaging and one of its uses is in ophthalmology where it is being used for analysis of the choroidal thickness in the eyes in healthy and disease states such as age-related macular degeneration, central serous chorioretinopathy, diabetic retinopathy and inherited retinal dystrophies. We have proposed a technique for enhancing the OCT images which can be used for clearly identifying and analyzing the particular diseases. Our method uses dictionary learning technique for generating a high resolution image from a single input LR image. We train two joint dictionaries, one with OCT images and the second with multiple different natural images, and compare the results with previous SR technique. Proposed method for both dictionaries produces HR images which are comparatively superior in quality with the other proposed method of SR. Proposed technique is very effective for noisy OCT images and produces up-sampled and enhanced OCT images.

  10. Highly sensitive optical sensor system for blood leakage detection

    Science.gov (United States)

    Ueda, Masahiro; Ishikawa, Kazuhiko; Jie, Chen; Sanae, Mizuno; Touma, Yasunori

    A highly sensitive method for the detection of blood leakage has been developed, and a practical sensor system for blood concentration measurement has been constructed. The present method is based on the attenuation of laser light by blood cells. The effects of the fluctuations of the incident laser light power are eliminated by normalizing the attenuated light intensity by the incident light intensity. A part of the incident laser light is reflected by a beam splitter mounted at the entrance of the test cell, of which the power is measured to provide base data for normalization. The optical path is extended to enhance sensitivity by using a pair of side mirrors. This multi-reflection method is very effective to increase sensitivity; the maximum sensitivity obtained for blood concentration is about 4 X 10 -6 by volume, which is significantly higher than that of the conventional sensors.

  11. Scalable photonic crystal chips for high sensitivity protein detection.

    Science.gov (United States)

    Liang, Feng; Clarke, Nigel; Patel, Parth; Loncar, Marko; Quan, Qimin

    2013-12-30

    Scalable microfabrication technology has enabled semiconductor and microelectronics industries, among other fields. Meanwhile, rapid and sensitive bio-molecule detection is increasingly important for drug discovery and biomedical diagnostics. In this work, we designed and demonstrated that photonic crystal sensor chips have high sensitivity for protein detection and can be mass-produced with scalable deep-UV lithography. We demonstrated label-free detection of carcinoembryonic antigen from pg/mL to μg/mL, with high quality factor photonic crystal nanobeam cavities.

  12. Experimental Investigation on a Highly Sensitive Atomic Magnetometer

    Institute of Scientific and Technical Information of China (English)

    LI Shu-Guang; XU Yun-Fei; WANG Zhao-Ying; LIU Yun-Xian; LIN Qiang

    2009-01-01

    A highly sensitive all-optical atomic magnetometer based on the magnetooptical effect which uses the advanced technique of single laser beam detection is reported and demonstrated experimentally.A sensitivityof 0.5 pT/Hz1/2 is obtained by analyzing the magnetic noise spectrum,which exceeds that of most traditional magnetometers.This kind of atomic magnetometer is very compact,has a low power consumption,and has a high theoretical sensitivity limit,which make it suitable for many applications.

  13. High-sensitivity, high-speed continuous imaging system

    Science.gov (United States)

    Watson, Scott A; Bender, III, Howard A

    2014-11-18

    A continuous imaging system for recording low levels of light typically extending over small distances with high-frame rates and with a large number of frames is described. Photodiode pixels disposed in an array having a chosen geometry, each pixel having a dedicated amplifier, analog-to-digital convertor, and memory, provide parallel operation of the system. When combined with a plurality of scintillators responsive to a selected source of radiation, in a scintillator array, the light from each scintillator being directed to a single corresponding photodiode in close proximity or lens-coupled thereto, embodiments of the present imaging system may provide images of x-ray, gamma ray, proton, and neutron sources with high efficiency.

  14. SuperSegger

    DEFF Research Database (Denmark)

    Stylianidou, Stella; Brennan, Connor; Nissen, Silas B

    2016-01-01

    -colonies with many cells, facilitating the analysis of cell-cycle dynamics in bacteria as well as cell-contact mediated phenomena. This package has a range of built-in capabilities for characterizing bacterial cells, including the identification of cell division events, mother, daughter, and neighboring cells......Many quantitative cell biology questions require fast yet reliable automated image segmentation to identify and link cells from frame-to-frame, and characterize the cell morphology and fluorescence. We present SuperSegger, an automated MATLAB-based image processing package well......-suited to quantitative analysis of high-throughput live-cell fluorescence microscopy of bacterial cells. SuperSegger incorporates machine-learning algorithms to optimize cellular boundaries and automated error resolution to reliably link cells from frame-to-frame. Unlike existing packages, it can reliably segment micro...

  15. Super-Hydrophobic High Throughput Electrospun Cellulose Acetate (CA) Nanofibrous Mats as Oil Selective Sorbents

    Science.gov (United States)

    Han, Chao

    The threat of oil pollution increases with the expansion of oil exploration and production activities, as well as the industrial growth around the world. Use of sorbents is a common method to deal with the oil spills. In this work, an advanced sorbent technology is described. A series of non-woven Cellulose Acetate (CA) nanofibrous mats with a 3D fibrous structure were synthesized by a novel high-throughput electrospinning technique. The precursor was solutions of CA/ acetic acid-acetone in various concentrations. Among them, 15.0% CA exhibits a superhydrophobic surface property, with a water contact angle of 128.95°. Its oil sorption capacity is many times higher the oil sorption capacity of the best commercial sorbent available in the market. Also, it showed good buoyancy properties on the water both as dry-mat and oil-saturated mat. In addition, it is biodegradable, easily available, easily manufactured, so the CA nanofibrous mat is an excellent candidate as oil sorbent for oil spill in water treatment.

  16. Becoming a high-fidelity - super - imitator: what are the contributions of social and individual learning?

    Science.gov (United States)

    Subiaul, Francys; Patterson, Eric M; Schilder, Brian; Renner, Elizabeth; Barr, Rachel

    2015-11-01

    In contrast to other primates, human children's imitation performance goes from low to high fidelity soon after infancy. Are such changes associated with the development of other forms of learning? We addressed this question by testing 215 children (26-59 months) on two social conditions (imitation, emulation) - involving a demonstration - and two asocial conditions (trial-and-error, recall) - involving individual learning - using two touchscreen tasks. The tasks required responding to either three different pictures in a specific picture order (Cognitive: Airplane→Ball→Cow) or three identical pictures in a specific spatial order (Motor-Spatial: Up→Down→Right). There were age-related improvements across all conditions and imitation, emulation and recall performance were significantly better than trial-and-error learning. Generalized linear models demonstrated that motor-spatial imitation fidelity was associated with age and motor-spatial emulation performance, but cognitive imitation fidelity was only associated with age. While this study provides evidence for multiple imitation mechanisms, the development of one of those mechanisms - motor-spatial imitation - may be bootstrapped by the development of another social learning skill - motor-spatial emulation. Together, these findings provide important clues about the development of imitation, which is arguably a distinctive feature of the human species.

  17. Characterising Super-Earths

    Directory of Open Access Journals (Sweden)

    Valencia D.

    2011-02-01

    Full Text Available The era of Super-Earths has formally begun with the detection of transiting low-mass exoplanets CoRoT-7b and GJ 1214b. In the path of characterising super-Earths, the first step is to infer their composition. While the discovery data for CoRoT-7b, in combination with the high atmospheric mass loss rate inferred from the high insolation, suggested that it was a rocky planet, the new proposed mass values have widened the possibilities. The combined mass range 1−10 M⊕ allows for a volatile-rich (and requires it if the mass is less than 4 M⊕ , an Earth-like or a super-Mercury-like composition. In contrast, the radius of GJ 1214b is too large to admit a solid composition, thus it necessarily to have a substantial gas layer. Some evidence suggests that within this gas layer H/He is a small but non-negligible component. These two planets are the first of many transiting low-mass exoplanets expected to be detected and they exemplify the limitations faced when inferring composition, which come from the degenerate character of the problem and the large error bars in the data.

  18. Discussion on super-tall structures type selection in high wind load area%谈高风载地区超高层结构选型

    Institute of Scientific and Technical Information of China (English)

    任军

    2016-01-01

    结合珠海某超高层建筑的结构设计参数,建立了四种结构体系,对不同的结构选型进行了分析比较,得到了不同结构形式的优缺点,为高风载地区超高层结构方案设计提供了参考依据。%Combining with the structure design parameters of a super-tall building in Zhuhai established four kinds of structure system,compared and analyzed different structure type selection,gained the advantages and disadvantages of different structure forms,provided reference basis for super-tall structures scheme design in high wind load areas.

  19. Large pi-aromatic molecules as potential sensitizers for highly efficient dye-sensitized solar cells.

    Science.gov (United States)

    Imahori, Hiroshi; Umeyama, Tomokazu; Ito, Seigo

    2009-11-17

    Recently, dye-sensitized solar cells have attracted much attention relevant to global environmental issues. Thus far, ruthenium(II) bipyridyl complexes have proven to be the most efficient TiO(2) sensitizers in dye-sensitized solar cells. However, a gradual increment in the highest power conversion efficiency has been recognized in the past decade. More importantly, considering that ruthenium is a rare metal, novel dyes without metal or using inexpensive metal are desirable for highly efficient dye-sensitized solar cells. Large pi-aromatic molecules, such as porphyrins, phthalocyanines, and perylenes, are important classes of potential sensitizers for highly efficient dye-sensitized solar cells, owing to their photostability and high light-harvesting capabilities that can allow applications in thinner, low-cost dye-sensitized solar cells. Porphyrins possess an intense Soret band at 400 nm and moderate Q bands at 600 nm. Nevertheless, the poor light-harvesting properties relative to the ruthenium complexes have limited the cell performance of porphyrin-sensitized TiO(2) cells. Elongation of the pi conjugation and loss of symmetry in porphyrins cause broadening and a red shift of the absorption bands together with an increasing intensity of the Q bands relative to that of the Soret band. On the basis of the strategy, the cell performance of porphyrin-sensitized solar cells has been improved intensively by the enhanced light absorption. Actually, some push-pull-type porphyrins have disclosed a remarkably high power conversion efficiency (6-7%) that was close to that of the ruthenium complexes. Phthalocyanines exhibit strong absorption around 300 and 700 nm and redox features that are similar to porphyrins. Moreover, phthalocyanines are transparent over a large region of the visible spectrum, thereby enabling the possibility of using them as "photovoltaic windows". However, the cell performance was poor, owing to strong aggregation and lack of directionality in the

  20. Portable High Sensitivity and High Resolution Sensor to Determine Oxygen Purity Levels Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of this Phase I STTR project is to develop a highly sensitive oxygen (O2) sensor, with high accuracy and precision, to determine purity levels of high...

  1. Aluminum nano-cantilevers for high sensitivity mass sensors

    DEFF Research Database (Denmark)

    Davis, Zachary James; Boisen, Anja

    2005-01-01

    We have fabricated Al nano-cantilevers using a very simple one mask contact UV lithography technique with lateral dimensions under 500 nm and vertical dimensions of approximately 100 nm. These devices are demonstrated as highly sensitive mass sensors by measuring their dynamic properties. Further...

  2. Highly Sensitive AMS Measurement of 53Mn at CIAE

    Institute of Scientific and Technical Information of China (English)

    DONG; Ke-jun; HU; Hao; LIU; Guang-shan; HE; Ming; LI; Zhen-yu; DOU; Liang; XIE; Lin-bo; LIU; Jian-cheng; WANG; Xiang-gao; SHEN; Hong-tao; LIN; De-yu; ZHENG; Guo-wen; WANG; Xiao-bo; LI; Heng; LI; Chao-li; WU; Shao-yong; YOU; Qu-bo; JIN; Chun-sheng; CHEN; Zhi-gang; YUAN; Jian; JIANG; Shan

    2013-01-01

    Methods for highly sensitive AMS measurement of 53Mn were explored by extracting different Mn-containing molecular ions in ion source and using different chemical forms of sample materials.Preliminary results indicate that a method for AMS measurement of 53Mn has been established and a-155355

  3. Sensitivity Study of Strapdown Inertial Sensors in High Performance Applications

    Science.gov (United States)

    1980-12-01

    system error varied with a change in heading 7K. ( xii 1 SENSITIVITY STUDY OF STRAPDOWN INERTIAL SENSORS IN HIGH PERFORMANCE APPLICATIONS I. Introduction...given in Tabla 10. 23 State Meaning o Basic Altitude Damped INS x(1) Error in East Longitude 5.7735 x 1O Ŗ arc min x(2) Error in North Latitude

  4. [Burner head with high sensitivity in atomic absorption spectroscopy].

    Science.gov (United States)

    Feng, X; Yang, Y

    1998-12-01

    This paper presents a burner head with gas-sample separate entrance and double access, which is used for atomic absorption spectroscopy. According to comparison and detection, the device can improve sensitivity by a factor of 1 to 5. In the meantime it has properties of high stability and resistance to interference.

  5. Microelectromechanical Resonant Accelerometer Designed with a High Sensitivity

    Science.gov (United States)

    Zhang, Jing; Su, Yan; Shi, Qin; Qiu, An-Ping

    2015-01-01

    This paper describes the design and experimental evaluation of a silicon micro-machined resonant accelerometer (SMRA). This type of accelerometer works on the principle that a proof mass under acceleration applies force to two double-ended tuning fork (DETF) resonators, and the frequency output of two DETFs exhibits a differential shift. The dies of an SMRA are fabricated using silicon-on-insulator (SOI) processing and wafer-level vacuum packaging. This research aims to design a high-sensitivity SMRA because a high sensitivity allows for the acceleration signal to be easily demodulated by frequency counting techniques and decreases the noise level. This study applies the energy-consumed concept and the Nelder-Mead algorithm in the SMRA to address the design issues and further increase its sensitivity. Using this novel method, the sensitivity of the SMRA has been increased by 66.1%, which attributes to both the re-designed DETF and the reduced energy loss on the micro-lever. The results of both the closed-form and finite-element analyses are described and are in agreement with one another. A resonant frequency of approximately 22 kHz, a frequency sensitivity of over 250 Hz per g, a one-hour bias stability of 55 μg, a bias repeatability (1σ) of 48 μg and the bias-instability of 4.8 μg have been achieved. PMID:26633425

  6. Microelectromechanical Resonant Accelerometer Designed with a High Sensitivity

    Directory of Open Access Journals (Sweden)

    Jing Zhang

    2015-12-01

    Full Text Available This paper describes the design and experimental evaluation of a silicon micro-machined resonant accelerometer (SMRA. This type of accelerometer works on the principle that a proof mass under acceleration applies force to two double-ended tuning fork (DETF resonators, and the frequency output of two DETFs exhibits a differential shift. The dies of an SMRA are fabricated using silicon-on-insulator (SOI processing and wafer-level vacuum packaging. This research aims to design a high-sensitivity SMRA because a high sensitivity allows for the acceleration signal to be easily demodulated by frequency counting techniques and decreases the noise level. This study applies the energy-consumed concept and the Nelder-Mead algorithm in the SMRA to address the design issues and further increase its sensitivity. Using this novel method, the sensitivity of the SMRA has been increased by 66.1%, which attributes to both the re-designed DETF and the reduced energy loss on the micro-lever. The results of both the closed-form and finite-element analyses are described and are in agreement with one another. A resonant frequency of approximately 22 kHz, a frequency sensitivity of over 250 Hz per g, a one-hour bias stability of 55 μg, a bias repeatability (1σ of 48 μg and the bias-instability of 4.8 μg have been achieved.

  7. What are super-enhancers?

    Science.gov (United States)

    Pott, Sebastian; Lieb, Jason D

    2015-01-01

    The term 'super-enhancer' has been used to describe groups of putative enhancers in close genomic proximity with unusually high levels of Mediator binding, as measured by chromatin immunoprecipitation and sequencing (ChIP-seq). Here we review the identification and composition of super-enhancers, describe links between super-enhancers, gene regulation and disease, and discuss the functional significance of enhancer clustering. We also provide our perspective regarding the proposition that super-enhancers are a regulatory entity conceptually distinct from what was known before the introduction of the term. Our opinion is that there is not yet strong evidence that super-enhancers are a novel paradigm in gene regulation and that use of the term in this context is not currently justified. However, the term likely identifies strong enhancers that exhibit behaviors consistent with previous models and concepts of transcriptional regulation. In this respect, the super-enhancer definition is useful in identifying regulatory elements likely to control genes important for cell type specification.

  8. Highly sensitive detection using microring resonator and nanopores

    Science.gov (United States)

    Bougot-Robin, K.; Hoste, J. W.; Le Thomas, N.; Bienstman, P.; Edel, J. B.

    2016-04-01

    One of the most significant challenges facing physical and biological scientists is the accurate detection and identification of single molecules in free-solution environments. The ability to perform such sensitive and selective measurements opens new avenues for a large number of applications in biological, medical and chemical analysis, where small sample volumes and low analyte concentrations are the norm. Access to information at the single or few molecules scale is rendered possible by a fine combination of recent advances in technologies. We propose a novel detection method that combines highly sensitive label-free resonant sensing obtained with high-Q microcavities and position control in nanoscale pores (nanopores). In addition to be label-free and highly sensitive, our technique is immobilization free and does not rely on surface biochemistry to bind probes on a chip. This is a significant advantage, both in term of biology uncertainties and fewer biological preparation steps. Through combination of high-Q photonic structures with translocation through nanopore at the end of a pipette, or through a solid-state membrane, we believe significant advances can be achieved in the field of biosensing. Silicon microrings are highly advantageous in term of sensitivity, multiplexing, and microfabrication and are chosen for this study. In term of nanopores, we both consider nanopore at the end of a nanopipette, with the pore being approach from the pipette with nanoprecise mechanical control. Alternatively, solid state nanopores can be fabricated through a membrane, supporting the ring. Both configuration are discussed in this paper, in term of implementation and sensitivity.

  9. Highly Mass-Sensitive Thin Film Plate Acoustic Resonators (FPAR)

    Science.gov (United States)

    Arapan, Lilia; Alexieva, Gergana; Avramov, Ivan D.; Radeva, Ekaterina; Strashilov, Vesseline; Katardjiev, Ilia; Yantchev, Ventsislav

    2011-01-01

    The mass sensitivity of thin aluminum nitride (AlN) film S0 Lamb wave resonators is theoretically and experimentally studied. Theoretical predictions based on modal and finite elements method analysis are experimentally verified. Here, two-port 888 MHz synchronous FPARs are micromachined and subsequently coated with hexamethyl-disiloxane(HMDSO)-plasma-polymerized thin films of various thicknesses. Systematic data on frequency shift and insertion loss versus film thickness are presented. FPARs demonstrate high mass-loading sensitivity as well as good tolerance towards the HMDSO viscous losses. Initial measurements in gas phase environment are further presented. PMID:22163994

  10. Highly mass-sensitive thin film plate acoustic resonators (FPAR).

    Science.gov (United States)

    Arapan, Lilia; Alexieva, Gergana; Avramov, Ivan D; Radeva, Ekaterina; Strashilov, Vesseline; Katardjiev, Ilia; Yantchev, Ventsislav

    2011-01-01

    The mass sensitivity of thin aluminum nitride (AlN) film S0 Lamb wave resonators is theoretically and experimentally studied. Theoretical predictions based on modal and finite elements method analysis are experimentally verified. Here, two-port 888 MHz synchronous FPARs are micromachined and subsequently coated with hexamethyl-disiloxane(HMDSO)-plasma-polymerized thin films of various thicknesses. Systematic data on frequency shift and insertion loss versus film thickness are presented. FPARs demonstrate high mass-loading sensitivity as well as good tolerance towards the HMDSO viscous losses. Initial measurements in gas phase environment are further presented.

  11. Design and Fabrication of High Sensitive Piezoresistive MEMS Accelerometer

    Directory of Open Access Journals (Sweden)

    JOSHI A.B

    2008-04-01

    Full Text Available This paper addresses the design and fabrication of high sensitive single axis piezoresistive micro-accelerometer for 50 g application. MEMS based accelerometer structure comprise of flexure fixed at one end and having attached proof mass at other end. This structure is designed and simulated using Coventorware. The simulation results show the sensitivity of 4mV/g. The structure is fabricated in N type silicon (100 substrate using Silicon bulk micromachining. This paper also discuses the use of PECVD Si3N4 layer as a masking material for silicon micromachining and process flow for accelerometer.

  12. Cardiac troponins and high-sensitivity cardiac troponin assays.

    Science.gov (United States)

    Conrad, Michael J; Jarolim, Petr

    2014-03-01

    Measurement of circulating cardiac troponins I and T has become integral to the diagnosis of myocardial infarction. This article discusses the structure and function of the troponin complex and the release of cardiac troponin molecules from the injured cardiomyocyte into the circulation. An overview of current cardiac troponin assays and their classification according to sensitivity is presented. The diagnostic criteria, role, and usefulness of cardiac troponin for myocardial infarction are discussed. In addition, several examples are given of the usefulness of high-sensitivity cardiac troponin assays for short-term and long-term prediction of adverse events.

  13. Highly Mass-Sensitive Thin Film Plate Acoustic Resonators (FPAR

    Directory of Open Access Journals (Sweden)

    Ventsislav Yantchev

    2011-07-01

    Full Text Available The mass sensitivity of thin aluminum nitride (AlN film S0 Lamb wave resonators is theoretically and experimentally studied. Theoretical predictions based on modal and finite elements method analysis are experimentally verified. Here, two-port 888 MHz synchronous FPARs are micromachined and subsequently coated with hexamethyl-disiloxane(HMDSO-plasma-polymerized thin films of various thicknesses. Systematic data on frequency shift and insertion loss versus film thickness are presented. FPARs demonstrate high mass-loading sensitivity as well as good tolerance towards the HMDSO viscous losses. Initial measurements in gas phase environment are further presented.

  14. Watching the Birth of Super Star Clusters

    CERN Document Server

    Turner, J L; Turner, Jean L.; Beck, Sara C.

    2003-01-01

    Subarcsecond infrared and radio observations yield important information about the formation of super star clusters from their surrounding gas. We discuss the general properties of ionized and molecular gas near young, forming SSCs, as illustrated by the prototypical young forming super star cluster nebula in the dwarf galaxy, NGC 5253. This super star cluster appears to have a gravitationally bound nebula. The lack of molecular gas suggests a very high star formation efficiency, consistent with the formation of a large, bound star cluster.

  15. Observation of Magnetic Signals from Earthquake Faulting Using High-resolution HTS-SQUID Magnetometer: Feasibility of Super-early Warning of Earthquakes

    Science.gov (United States)

    Katori, Y.; Okubo, K.; Hato, T.; Tsukamoto, A.; Tanabe, K.; Onishi, N.; Furukawa, H.; Isogami, S.; Takeuchi, N.

    2015-12-01

    Electromagnetic changes associated with earthquakes have been investigated previously. Our research group has also employed the magnetometers for seismomagnetic observations since March 2004. Our observation site happened to be situated at an epicentral distance of 26 km from the 2008 Iwate-Miyagi Nairiku earthquake ofM7.2, NE Japan. In this earthquake, we have reported successful observation of "co-faulting" Earth's magnetic field changes (Okubo et al., 2011 EPSL). Magnetic fields began to change almost simultaneously with the onset of the earthquake rupture and grew before the first P wave arrival. Such magnetic signals are most probably generated by the changing stress field due to earthquake rupturing, i.e. the piezomagnetic effect. On the other hand, this observation result suggested that the geomagnetic variation signal accompanying fault movement, whose sources are the piezomagnetic effects, is very small. The observed change of geomagnetic field might be approximately less than several hundred pico-tesla. Therefore, to obtain more observation data of "co-faulting" magnetic field change, development of a higher-sensitive magnetometer system is very important. Then, our research group tried to develop the HTS-SQUID (high-temperature-superconductor based superconducting-quantum-interference-device) magnetometer systems for high-resolution observation of Earth's magnetic field. Since March 2012 we have introduced long-term precise geomagnetic observations using the HTS-SQUID magnetometer system Unit No.1 (mark I) at Iwaki observation site (IWK) in Fukushima, Japan. Additionally, since October 2014, we have also introduced the new HTS- SQUID magnetometer system Unit No.2 (mark II). The sampling interval of the magnetometers is 0.02 sec (50Hz). The system clock has been synchronized by use of GPS signals. A high-resolution accelerometer is also installed at observation point. In this study, we show the observation results of geomagnetic field changes associated

  16. High Sensitivity Very Low Frequency Receiver for Earthquake Data Acquisition.

    Science.gov (United States)

    Munir, A.; Najmurrokhman, A.

    2017-03-01

    high sensitivity very low frequency (VLF) receiver is developed based on AD744 monolithic operational amplifier (Op-Amp) for earthquake data acquisition. In research related natural phenomena such as atmospheric noise, lightning and earthquake, a VLF receiver particularly with high sensitivity is utterly required due to the low power of VLF wave signals received by the antenna. The developed receiver is intended to have high sensitivity reception for the signals in frequency range of 10-30kHz allocated for earthquake observation. The VLF receiver which is portably designed is also equipped with an output port connectable to the soundcard of personal computer for further data acquisition. After obtaining the optimum design, the hardware realization is implemented on a printed circuit board (PCB) for experimental characterization. It shows that the sensitivity of realized VLF receiver is almost linear in the predefined frequency range for the input signals lower than -12dBm and to be quadratic for the higher level input signals.

  17. High Sensitivity Polymer Optical Fiber-Bragg-Grating-Based Accelerometer

    DEFF Research Database (Denmark)

    Stefani, Alessio; Andresen, Søren; Yuan, Wu

    2012-01-01

    We report on the fabrication and characterization of the first accelerometer based on a polymer optical fiber Bragg grating (FBG) for operation at both 850 and 1550 nm. The devices have a flat frequency response over a 1-kHz bandwidth and a resonance frequency of about 3 kHz. The response is linear...... up to at least 15 g and sensitivities as high as 19 pm/g (shift in resonance wavelength per unit acceleration) have been demonstrated. Given that 15 g corresponds to a strain of less than 0.02% and that polymer fibers have an elastic limit of more than 1%, the polymer FBG accelerometer can measure...... very strong accelerations. We compare with corresponding silica FBG accelerometers and demonstrate that using polymer FBGs improves the sensitivity by more than a factor of four and increases the figure of merit, defined as the sensitivity times the resonance frequency squared....

  18. Are Inflationary Predictions Sensitive to Very High Energy Physics?

    CERN Document Server

    Burgess, C P; Lemieux, F; Holman, R

    2003-01-01

    It has been proposed that the successful inflationary description of density perturbations on cosmological scales is sensitive to the details of physics at extremely high (trans-Planckian) energies. We test this proposal by examining how inflationary predictions depend on higher-energy scales within a simple model where the higher-energy physics is well understood. We find the best of all possible worlds: inflationary predictions are robust against the vast majority of high-energy effects, but can be sensitive to some effects in certain circumstances, in a way which does not violate ordinary notions of decoupling. This implies both that the comparison of inflationary predictions with CMB data is meaningful, and that it is also worth searching for small deviations from the standard results in the hopes of learning about very high energies.

  19. Cultivar and Tree Density As Key Factors in the Long-Term Performance of Super High-Density Olive Orchards

    Science.gov (United States)

    Díez, Concepción M.; Moral, Juan; Cabello, Diego; Morello, Pablo; Rallo, Luis; Barranco, Diego

    2016-01-01

    Super high-density (SHD) olive orchards are rapidly expanding since the first plantation was set up in Spain in the 1990s. Because there are no long-term studies characterizing these systems, it is unknown if densities above a certain threshold could trigger competition among fully-grown trees, compromising their development. Over 14 years we have evaluated the performance of the major olive cultivars currently planted in SHD systems (“Arbequina,” Arbequina IRTA-i·18, “Arbosana,” “Fs-17,” and “Koroneiki”) and nine SHD designs ranging from 780 to 2254 trees ha−1 for the cultivar “Arbequina.” Remarkably, the accumulated fruit and oil production of the five cultivars increased linearly over time. Our data indicated the favorable long-term performance of the evaluated cultivars with an average annual oil production of 2.3 t ha−1. Only “Fs-17” did not perform well to the SHD system in our conditions and it yielded about half (1.2 t ha−1) of the other cultivars. In the density trial for “Arbequina,” both fruit and oil accumulated production increased over time as a function of tree density. Thus, the accumulated oil yield ranged from 16.1 t ha−1 for the lowest density (780 trees ha−1) to 29.9 t ha−1 for the highest (2254 trees ha−1). In addition, we note that the accumulated production per surface unit showed a better correlation with the hedgerow length than the tree density. Thus, the current planting designs of SHD olive orchards can be further improved taking this parameter into account. Despite observations that some irregular patterns of crop distribution have arisen, our olive hedgerows are still fully productive after 14 years of planting. This result contradicts previous experiences that showed declines in production 7 or 8 years after planting due to high vigor, shading, and limited ventilation. PMID:27602035

  20. Design of highly sensitive multichannel bimetallic photonic crystal fiber biosensor

    Science.gov (United States)

    Hameed, Mohamed Farhat O.; Alrayk, Yassmin K. A.; Shaalan, Abdelhamid A.; El Deeb, Walid S.; Obayya, Salah S. A.

    2016-10-01

    A design of a highly sensitive multichannel biosensor based on photonic crystal fiber is proposed and analyzed. The suggested design has a silver layer as a plasmonic material coated by a gold layer to protect silver oxidation. The reported sensor is based on detection using the quasi transverse electric (TE) and quasi transverse magnetic (TM) modes, which offers the possibility of multichannel/multianalyte sensing. The numerical results are obtained using a finite element method with perfect matched layer boundary conditions. The sensor geometrical parameters are optimized to achieve high sensitivity for the two polarized modes. High-refractive index sensitivity of about 4750 nm/RIU (refractive index unit) and 4300 nm/RIU with corresponding resolutions of 2.1×10-5 RIU, and 2.33×10-5 RIU can be obtained according to the quasi TM and quasi TE modes of the proposed sensor, respectively. Further, the reported design can be used as a self-calibration biosensor within an unknown analyte refractive index ranging from 1.33 to 1.35 with high linearity and high accuracy. Moreover, the suggested biosensor has advantages in terms of compactness and better integration of microfluidics setup, waveguide, and metallic layers into a single structure.

  1. Sensitivity of HAWC to high-mass dark matter annihilations

    Science.gov (United States)

    Abeysekara, A. U.; Alfaro, R.; Alvarez, C.; Álvarez, J. D.; Arceo, R.; Arteaga-Velázquez, J. C.; Ayala Solares, H. A.; Barber, A. S.; Baughman, B. M.; Bautista-Elivar, N.; Becerra Gonzalez, J.; Belmont, E.; BenZvi, S. Y.; Berley, D.; Bonilla Rosales, M.; Braun, J.; Caballero-Lopez, R. A.; Caballero-Mora, K. S.; Carramiñana, A.; Castillo, M.; Cotti, U.; Cotzomi, J.; de la Fuente, E.; De León, C.; DeYoung, T.; Diaz Hernandez, R.; Diaz-Cruz, L.; Díaz-Vélez, J. C.; Dingus, B. L.; DuVernois, M. A.; Ellsworth, R. W.; Fiorino, D. W.; Fraija, N.; Galindo, A.; Garfias, F.; González, M. M.; Goodman, J. A.; Grabski, V.; Gussert, M.; Hampel-Arias, Z.; Harding, J. P.; Hui, C. M.; Hüntemeyer, P.; Imran, A.; Iriarte, A.; Karn, P.; Kieda, D.; Kunde, G. J.; Lara, A.; Lauer, R. J.; Lee, W. H.; Lennarz, D.; León Vargas, H.; Linares, E. C.; Linnemann, J. T.; Longo, M.; Luna-Garcia, R.; Marinelli, A.; Martinez, H.; Martinez, O.; Martínez-Castro, J.; Matthews, J. A. J.; McEnery, J.; Mendoza Torres, E.; Miranda-Romagnoli, P.; Moreno, E.; Mostafá, M.; Nellen, L.; Newbold, M.; Noriega-Papaqui, R.; Oceguera-Becerra, T.; Patricelli, B.; Pelayo, R.; Pérez-Pérez, E. G.; Pretz, J.; Rivière, C.; Rosa-González, D.; Ryan, J.; Salazar, H.; Salesa, F.; Sanchez, F. E.; Sandoval, A.; Schneider, M.; Silich, S.; Sinnis, G.; Smith, A. J.; Sparks Woodle, K.; Springer, R. W.; Taboada, I.; Toale, P. A.; Tollefson, K.; Torres, I.; Ukwatta, T. N.; Villaseñor, L.; Weisgarber, T.; Westerhoff, S.; Wisher, I. G.; Wood, J.; Yodh, G. B.; Younk, P. W.; Zaborov, D.; Zepeda, A.; Zhou, H.; Abazajian, K. N.; Milagro Collaboration

    2014-12-01

    The High Altitude Water Cherenkov (HAWC) observatory is a wide field-of-view detector sensitive to gamma rays of 100 GeV to a few hundred TeV. Located in central Mexico at 19° North latitude and 4100 m above sea level, HAWC will observe gamma rays and cosmic rays with an array of water Cherenkov detectors. The full HAWC array is scheduled to be operational in Spring 2015. In this paper, we study the HAWC sensitivity to the gamma-ray signatures of high-mass (multi-TeV) dark matter annihilation. The HAWC observatory will be sensitive to diverse searches for dark matter annihilation, including annihilation from extended dark matter sources, the diffuse gamma-ray emission from dark matter annihilation, and gamma-ray emission from nonluminous dark matter subhalos. Here we consider the HAWC sensitivity to a subset of these sources, including dwarf galaxies, the M31 galaxy, the Virgo cluster, and the Galactic center. We simulate the HAWC response to gamma rays from these sources in several well-motivated dark matter annihilation channels. If no gamma-ray excess is observed, we show the limits HAWC can place on the dark matter cross section from these sources. In particular, in the case of dark matter annihilation into gauge bosons, HAWC will be able to detect a narrow range of dark matter masses to cross sections below thermal. HAWC should also be sensitive to nonthermal cross sections for masses up to nearly 1000 TeV. The constraints placed by HAWC on the dark matter cross section from known sources should be competitive with current limits in the mass range where HAWC has similar sensitivity. HAWC can additionally explore higher dark matter masses than are currently constrained.

  2. Direct Growth of Graphene Films on 3D Grating Structural Quartz Substrates for High-Performance Pressure-Sensitive Sensors.

    Science.gov (United States)

    Song, Xuefen; Sun, Tai; Yang, Jun; Yu, Leyong; Wei, Dacheng; Fang, Liang; Lu, Bin; Du, Chunlei; Wei, Dapeng

    2016-07-06

    Conformal graphene films have directly been synthesized on the surface of grating microstructured quartz substrates by a simple chemical vapor deposition process. The wonderful conformality and relatively high quality of the as-prepared graphene on the three-dimensional substrate have been verified by scanning electron microscopy and Raman spectra. This conformal graphene film possesses excellent electrical and optical properties with a sheet resistance of 80% (at 550 nm), which can be attached with a flat graphene film on a poly(dimethylsiloxane) substrate, and then could work as a pressure-sensitive sensor. This device possesses a high-pressure sensitivity of -6.524 kPa(-1) in a low-pressure range of 0-200 Pa. Meanwhile, this pressure-sensitive sensor exhibits super-reliability (≥5000 cycles) and an ultrafast response time (≤4 ms). Owing to these features, this pressure-sensitive sensor based on 3D conformal graphene is adequately introduced to test wind pressure, expressing higher accuracy and a lower background noise level than a market anemometer.

  3. AlPO4-C Composite Coating on Ni-based Super Alloy Substrates for High Emissivity Applications : Experimentation on Dip Coating and Spray Coating

    OpenAIRE

    Subir Roy; S. Rangaswamy Reddy; Sindhuja, P; Dipak Das; V.V. Bhauprasad

    2016-01-01

    High emissivity coating was developed on Ni-based super alloy substrates by dip coating and spray coating technique using a chemical precursor sol. The coating material was characterised thoroughly by XRD, SEM, TEM and XPS analyses. Characterisation results showed the presence of nano carbon in the AlPO4 matrix which imparted high emissivity to the coating. Emissivity of the coating varied from 0.6 to 0.9 in the wave length range : 2 µm - 25 µm depending on the thickness of the multilayered c...

  4. Super-multiplex vibrational imaging

    Science.gov (United States)

    Wei, Lu; Chen, Zhixing; Shi, Lixue; Long, Rong; Anzalone, Andrew V.; Zhang, Luyuan; Hu, Fanghao; Yuste, Rafael; Cornish, Virginia W.; Min, Wei

    2017-04-01

    The ability to visualize directly a large number of distinct molecular species inside cells is increasingly essential for understanding complex systems and processes. Even though existing methods have successfully been used to explore structure-function relationships in nervous systems, to profile RNA in situ, to reveal the heterogeneity of tumour microenvironments and to study dynamic macromolecular assembly, it remains challenging to image many species with high selectivity and sensitivity under biological conditions. For instance, fluorescence microscopy faces a ‘colour barrier’, owing to the intrinsically broad (about 1,500 inverse centimetres) and featureless nature of fluorescence spectra that limits the number of resolvable colours to two to five (or seven to nine if using complicated instrumentation and analysis). Spontaneous Raman microscopy probes vibrational transitions with much narrower resonances (peak width of about 10 inverse centimetres) and so does not suffer from this problem, but weak signals make many bio-imaging applications impossible. Although surface-enhanced Raman scattering offers high sensitivity and multiplicity, it cannot be readily used to image specific molecular targets quantitatively inside live cells. Here we use stimulated Raman scattering under electronic pre-resonance conditions to image target molecules inside living cells with very high vibrational selectivity and sensitivity (down to 250 nanomolar with a time constant of 1 millisecond). We create a palette of triple-bond-conjugated near-infrared dyes that each displays a single peak in the cell-silent Raman spectral window; when combined with available fluorescent probes, this palette provides 24 resolvable colours, with the potential for further expansion. Proof-of-principle experiments on neuronal co-cultures and brain tissues reveal cell-type-dependent heterogeneities in DNA and protein metabolism under physiological and pathological conditions, underscoring the

  5. Development of High Sensitivity Nuclear Emulsion and Fine Grained Emulsion

    Energy Technology Data Exchange (ETDEWEB)

    Kawahara, H.; Asada, T. [Department of Physics, Nagoya University, Nagoya 464-8602 (Japan); Naka, T. [Institute of Advanced Research, Nagoya University (Japan); Naganawa, N.; Kuwabara, K.; Nakamura, M. [Department of Physics, Nagoya University, Nagoya 464-8602 (Japan)

    2014-08-15

    Nuclear emulsion is a particle detector having high spacial resolution and angular resolution. It became useful for large statistics experiment thanks to the development of automatic scanning system. In 2010, a facility for emulsion production was introduced and R and D of nuclear emulsion began at Nagoya university. In this paper, we present results of development of the high sensitivity emulsion and fine grained emulsion for dark matter search experiment. Improvement of sensitivity is achieved by raising density of silver halide crystals and doping well-adjusted amount of chemicals. Production of fine grained emulsion was difficult because of unexpected crystal condensation. By mixing polyvinyl alcohol (PVA) to gelatin as a binder, we succeeded in making a stable fine grained emulsion.

  6. Highly sensitive troponin T in patients with acute ischemic stroke

    DEFF Research Database (Denmark)

    Jensen, J K; Ueland, T; Aukrust, P;

    2012-01-01

    in decedents than in survivors. After adjustment for stroke severity, C-reactive protein, age, NT-proBNP and prior heart and/or renal failure, hsTnT levels were not a significant predictor of long-term all-cause or cardiovascular mortality. Conclusion: Elevated levels of hsTnT are frequently present......Background: Newly developed troponin assays have superior diagnostic and prognostic performance in acute coronary syndrome (ACS), when compared to conventional troponin assays; however, highly sensitive troponin has not been evaluated in patients with acute ischemic stroke. Methods: Highly...... sensitive troponin T (hsTnT) was measured daily during the first 4 days in 193 consecutive patients with acute ischemic stroke without overt ACS or atrial fibrillation. The patients were previously tested normal with a fourth-generation TnT assay. The patients were followed for 47 months, with all...

  7. UK low-background infrastructure for delivering SuperNEMO

    CERN Document Server

    Liu, Xin Ran

    2015-01-01

    SuperNEMO is a next generation neutrinoless double beta decay experiment with a design capability to reach a half-life sensitivity of $10^{26}$ years corresponding to an effective Majorana neutrino mass of $\\langle m_{\\beta\\beta} \\rangle$ $<$ 50 - 100 meV. To achieve this sensitivity, stringent radio-purity requirements are imposed resulting in an equally stringent screening programme. Dedicated facilities have been established in the UK for screening and selection of detector construction materials. Gamma ray spectroscopy using high-purity germanium (HPGe) detectors has been the standard method for the measurement of material contamination. A low-background facility has been established at Boulby Underground Laboratory. The first results from the 2 current HPGe detector are shown. Radon is one of the most critical backgrounds for SuperNEMO and most other low background experiments. It can enter the detector either through diffusion, contamination during construction or emanation from the detector material...

  8. Structural Glycomic Analyses at High Sensitivity: A Decade of Progress

    Science.gov (United States)

    Alley, William R.; Novotny, Milos V.

    2013-06-01

    The field of glycomics has recently advanced in response to the urgent need for structural characterization and quantification of complex carbohydrates in biologically and medically important applications. The recent success of analytical glycobiology at high sensitivity reflects numerous advances in biomolecular mass spectrometry and its instrumentation, capillary and microchip separation techniques, and microchemical manipulations of carbohydrate reactivity. The multimethodological approach appears to be necessary to gain an in-depth understanding of very complex glycomes in different biological systems.

  9. Highly Sensitive Flexible Magnetic Sensor Based on Anisotropic Magnetoresistance Effect.

    Science.gov (United States)

    Wang, Zhiguang; Wang, Xinjun; Li, Menghui; Gao, Yuan; Hu, Zhongqiang; Nan, Tianxiang; Liang, Xianfeng; Chen, Huaihao; Yang, Jia; Cash, Syd; Sun, Nian-Xiang

    2016-11-01

    A highly sensitive flexible magnetic sensor based on the anisotropic magnetoresistance effect is fabricated. A limit of detection of 150 nT is observed and excellent deformation stability is achieved after wrapping of the flexible sensor, with bending radii down to 5 mm. The flexible AMR sensor is used to read a magnetic pattern with a thickness of 10 μm that is formed by ferrite magnetic inks.

  10. New method for making super-plastic glasses

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    @@ It was a long-cherished dream for materials scientists to find a nearly ideal metallic alloy with high strength and super-plasticity concurrently as a super-material both extremely strong and exceptionally hard for human use.

  11. Development and Challenges of Super High Dams in China and Other Countries%我国超级高坝的发展与挑战

    Institute of Scientific and Technical Information of China (English)

    王爱玲; 邓正刚

    2015-01-01

    The statistics on high dams with a height more than 200 m in abroad and home under operation, construction or planning shows that the super high dam construct earlier and continues to develop in foreign countries, and starts later in but rapid in China. The super high dams mainly belong to concrete arch dam, concrete gravity dam, clay core wall rockfill dam or concrete face rockfill dam, and all super high dams which have been put into operation can safely and reliably operate. The development and characteristics of hydropower engineering in China are analyzed and the result shows the development of super high dams in China will face the challenges of high safety requirement, lack of relevant technical standards, joint research requirements on key technologies, risk prevention and control and effective management in whole operation life.%对国内外已建、在建和拟建200 m以上超级高坝进行统计表明,国外超级高坝建设起步较早,发展持续不断,我国起步较晚,但发展较快;超级高坝主要集中在混凝土拱坝、混凝土重力坝、土心墙堆石坝和混凝土面板堆石坝等4种坝型,已建工程都能安全可靠运行。通过分析我国水电工程发展趋势以及工程特点,我国超级高坝的发展面临安全要求高、相关技术标准缺乏、关键技术需联合攻关、风险防控和全寿命周期的有效管理等方面的挑战。

  12. Recent trends in high spin sensitivity magnetic resonance

    Science.gov (United States)

    Blank, Aharon; Twig, Ygal; Ishay, Yakir

    2017-07-01

    new ideas, show how these limiting factors can be mitigated to significantly improve the sensitivity of induction detection. Finally, we outline some directions for the possible applications of high-sensitivity induction detection in the field of electron spin resonance.

  13. Pulsed Discharge Helium Ionization Detector for Highly Sensitive Aquametry.

    Science.gov (United States)

    Mowry, Curtis D; Pimentel, Adam S; Sparks, Elizabeth S; Moorman, Matthew W; Achyuthan, Komandoor E; Manginell, Ronald P

    2016-01-01

    Trace moisture quantitation is crucial in medical, civilian and military applications. Current aquametry technologies are limited by the sample volume, reactivity, or interferences, and/or instrument size, weight, power, cost, and complexity. We report for the first time on the use of a pulsed discharge helium ionization detector (PDHID-D2) (∼196 cm(3)) for the sensitive (limit of detection, 0.047 ng; 26 ppm), linear (r(2) >0.99), and rapid (volume of liquid or gas. The relative humidity sensitivity was 0.22% (61.4 ppmv) with a limit of detection of less than 1 ng moisture with gaseous samples. The sensitivity was 10 to 100 to fold superior to competing technologies without the disadvantages inherent to these technologies. The PDHID-D2, due to its small footprint and low power requirement, has good size, weight, and power-portability (SWAPP) factors. The relatively low cost (∼$5000) and commercial availability of the PDHID-D2 makes our technique applicable to highly sensitive aquametry.

  14. Study on the Practice and High-yielding Mechanism of Super-sparse-cultivation Associated with Maximum-tiller Seedling of Hybrid Rice

    Institute of Scientific and Technical Information of China (English)

    MA Jun; TAO Shi-shun

    2002-01-01

    In this paper, a new cultivation practice-super-sparse-cultivation associated with maximumtiller seedling (SSCMTS) of hybrid rice was proposed and its high-yielding mechanism was studied. The results showed that the practice of SSCMTS in hybrid rice could not only increase grain yield but also save seeds and labor. It was a new high-yielding way for the late transplanting seedlings and heavy panicle type hybrid rice cultivars to further utilize the high-yielding potential of hybrid rice cultivars. The increasing number of spikelets and ideal grain -filling were the direct factors for the high yield of SSCMTS in hybrid rice, and those high-yielding factors relied on high quality seedlings, sturdy individuals, high quality population and vigorous later growth.

  15. High Sensitivity pH Sensor Based on Porous Silicon (PSi) Extended Gate Field-Effect Transistor

    Science.gov (United States)

    Al-Hardan, Naif H.; Abdul Hamid, Muhammad Azmi; Ahmed, Naser M.; Jalar, Azman; Shamsudin, Roslinda; Othman, Norinsan Kamil; Kar Keng, Lim; Chiu, Weesiong; Al-Rawi, Hamzah N.

    2016-01-01

    In this study, porous silicon (PSi) was prepared and tested as an extended gate field-effect transistor (EGFET) for pH sensing. The prepared PSi has pore sizes in the range of 500 to 750 nm with a depth of approximately 42 µm. The results of testing PSi for hydrogen ion sensing in different pH buffer solutions reveal that the PSi has a sensitivity value of 66 mV/pH that is considered a super Nernstian value. The sensor considers stability to be in the pH range of 2 to 12. The hysteresis values of the prepared PSi sensor were approximately 8.2 and 10.5 mV in the low and high pH loop, respectively. The result of this study reveals a promising application of PSi in the field for detecting hydrogen ions in different solutions. PMID:27338381

  16. High Sensitivity pH Sensor Based on Porous Silicon (PSi Extended Gate Field-Effect Transistor

    Directory of Open Access Journals (Sweden)

    Naif H. Al-Hardan

    2016-06-01

    Full Text Available In this study, porous silicon (PSi was prepared and tested as an extended gate field-effect transistor (EGFET for pH sensing. The prepared PSi has pore sizes in the range of 500 to 750 nm with a depth of approximately 42 µm. The results of testing PSi for hydrogen ion sensing in different pH buffer solutions reveal that the PSi has a sensitivity value of 66 mV/pH that is considered a super Nernstian value. The sensor considers stability to be in the pH range of 2 to 12. The hysteresis values of the prepared PSi sensor were approximately 8.2 and 10.5 mV in the low and high pH loop, respectively. The result of this study reveals a promising application of PSi in the field for detecting hydrogen ions in different solutions.

  17. Development of a highly sensitive galvanic cell oxygen sensor.

    Science.gov (United States)

    Ogino, H; Asakura, K

    1995-02-01

    A highly sensitive galvanic cell oxygen sensor was successfully developed for determining parts per billion of oxygen in high purity gases such as nitrogen, argon, etc. The response of this improved sensor was proportional in the range of oxygen concentrations from 10.0 ppm to the detection limit. The response speed in this study was improved to within 90 sec for a 90% response. The detection limit was tentatively found to be less than 0.4 ppb corresponding to S N = 2 .

  18. Super insulating aerogel glazing

    DEFF Research Database (Denmark)

    Schultz, Jørgen Munthe; Jensen, Karsten Ingerslev; Kristiansen, Finn Harken

    2004-01-01

    Monolithic silica aerogel offers the possibility of combining super insulation and high solar energy transmittance, which has been the background for a previous and a current EU project on research and development of monolithic silica aerogel as transparent insulation in windows. Generally, windows...... form the weakest part of the thermal envelope with respect to heat loss coefficient, but on the other hand also play an important role for passive solar energy utilisation. For window orientations other than south, the net energy balance will be close to or below zero. However, the properties...

  19. The superB silicon vertex tracker

    Energy Technology Data Exchange (ETDEWEB)

    Rizzo, G., E-mail: giuliana.rizzo@pi.infn.i [INFN-Pisa and Universita di Pisa (Italy); Avanzini, C.; Batignani, G.; Bettarini, S.; Bosi, F.; Calderini, G.; Ceccanti, M.; Cenci, R.; Cervelli, A.; Crescioli, F.; Dell' Orso, M.; Forti, F.; Giannetti, P.; Giorgi, M.A. [INFN-Pisa and Universita di Pisa (Italy); Lusiani, A. [Scuola Normale Superiore and INFN-Pisa (Italy); Gregucci, S.; Mammini, P.; Marchiori, G.; Massa, M.; Morsani, F. [INFN-Pisa and Universita di Pisa (Italy)

    2010-05-21

    The SuperB asymmetric e{sup +}-e{sup -} collider has been designed to deliver a luminosity greater than 10{sup 36}cm{sup -2}s{sup -1} with moderate beam currents. Comparing to current B-Factories, the reduced center of mass boost of the SuperB machine requires improved vertex resolution to allow precision measurements sensitive to New Physics. We present the conceptual design of the silicon vertex tracker (SVT) for the SuperB detector with the present status of the R and D on the different options under study for its innermost Layer0.

  20. Performance of terahertz metamaterials as high-sensitivity sensor

    Science.gov (United States)

    He, Yanan; Zhang, Bo; Shen, Jingling

    2017-09-01

    A high-sensitivity sensor based on the resonant transmission characteristics of terahertz (THz) metamaterials was investigated, with the proposal and fabrication of rectangular bar arrays of THz metamaterials exhibiting a period of 180 μm on a 25 μm thick flexible polyimide. Varying the size of the metamaterial structure revealed that the length of the rectangular unit modulated the resonant frequency, which was verified by both experiment and simulation. The sensing characteristics upon varying the surrounding media in the sample were tested by simulation and experiment. Changing the surrounding medium from that of air to that of alcohol or oil produced resonant frequency redshifts of 80 GHz or 150 GHz, respectively, which indicates that the sensor possessed a high sensitivity of 667 GHz per unit of refractive index. Finally, the influence of the sample substrate thickness on the sensor sensitivity was investigated by simulation. It may be a reference for future sensor design.

  1. High-sensitivity strain visualization using electroluminescence technologies

    Science.gov (United States)

    Xu, Jian; Jo, Hongki

    2016-04-01

    Visualizing mechanical strain/stress changes is an emerging area in structural health monitoring. Several ways are available for strain change visualization through the color/brightness change of the materials subjected to the mechanical stresses, for example, using mechanoluminescence (ML) materials and mechanoresponsive polymers (MRP). However, these approaches were not effectively applicable for civil engineering system yet, due to insufficient sensitivity to low-level strain of typical civil structures and limitation in measuring both static and dynamic strain. In this study, design and validation for high-sensitivity strain visualization using electroluminescence technologies are presented. A high-sensitivity Wheatstone bridge, of which bridge balance is precisely controllable circuits, is used with a gain-adjustable amplifier. The monochrome electroluminescence (EL) technology is employed to convert both static and dynamic strain change into brightness/color change of the EL materials, through either brightness change mode (BCM) or color alternation mode (CAM). A prototype has been made and calibrated in lab, the linearity between strain and brightness change has been investigated.

  2. High-sensitive scanning laser magneto-optical imaging system.

    Science.gov (United States)

    Murakami, Hironaru; Tonouchi, Masayoshi

    2010-01-01

    A high-sensitive scanning laser magneto-optical (MO) imaging system has been developed. The system is mainly composed of a laser source, galvano meters, and a high-sensitive differential optical-detector. Preliminary evaluation of system performance by using a Faraday indicator with a Faraday rotation coefficient of 3.47 x 10(-5) rad/microm Oe shows a magnetic sensitivity of about 5 microT, without any need for accumulation or averaging processing. Using the developed MO system we have succeeded in the fast and quantitative imaging of a rotationally symmetric magnetic field distribution around an YBa(2)Cu(3)O(7-delta) (YBCO) strip line applied with dc-biased current, and also succeeded in the detection of quantized fine signals corresponding to magnetic flux quantum generation in a superconducting loop of an YBCO Josephson vortex flow transistor. Thus, the developed system enables us not only to do fast imaging and local signal detection but also to directly evaluate both the strength and direction of a magnetic signal.

  3. HIGHLY SENSITIVE CATALASE ELECTRODE BASED ON POLYPYRROLE FILMS WITH MICROCONTAINERS

    Institute of Scientific and Technical Information of China (English)

    Yu-ying Gao; Gao-quan Shi

    2006-01-01

    Highly sensitive catalase electrodes for sensing hydrogen peroxide have been fabricated based on polypyrrole films with microcontainers. The microcontainers have a cup-like morphology and are arranged in a density of 4000 units cm-2.Catalase was immobilized into the polypyrrole films with microcontainers (Ppy-mc), which were coated on a Pt substrate electrode. The catalase/Ppy-mc/Pt electrode showed linear response to hydrogen peroxide in the range of 0-18 mmol/L at a potential of -0.3 V (versus SCE). Its sensitivity was measured to be approximately 3.64 μA (mmol/L)-1 cm-2, which is about two times that of the electrode fabricated from a flat Ppy film (catalase/Ppy-flat/Pt electrode). The electrode is highly selective for hydrogen peroxide and its sensitivity is interfered by potential interferents such as ascorbic acid, urea and fructose. Furthermore, such catalase electrodes showed long-term storage stability of 15 days under dry conditions at 4℃.

  4. 超限高层建筑电气设计重点简析%Analysis on Key Points of Electrical Design for Super High-rise Buildings

    Institute of Scientific and Technical Information of China (English)

    华锡锋

    2012-01-01

    In combination with project cases, the key points of electrical design for the following aspects of super high-rise buildings are deeply analyzed : power supply scheme, emergency / stand-by power source, transformation and distribution substation, and escape lighting etc.%结合工程案例.对超限高层建筑的供电方案、应急/备用电源、变配电所,以及疏散照明等电气设计重点内容作深入分析。

  5. The Power Control System of Constant Power Super-high Pressure Mercury Lamp%超高压汞灯功率控制研究

    Institute of Scientific and Technical Information of China (English)

    刘卫平; 葛劢冲

    2012-01-01

    A super-high pressure mercury lamp power of mask aligner is introduced in this paper,using analogue power feedback control,effectively improving power stability.The principle and major circuit structure of constant power control are emphatically expounded in this paper.%介绍了一种光刻机超高压汞灯电源,采用模拟功率反馈控制,有效提高了光源稳定性;重点阐述了恒功率控制的原理和主要电路结构。

  6. Effect of low-frequency electromagnetic field on the as-cast microstructure of a new super high strength aluminum alloy by horizontal continuous casting

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    The super high strength aluminum alloy ingots with 100 mm in diameter were cast by the process of low-frequency electromagnetic horizontal continuous casting (LFEHC) and the effect of electromagnetic field on the as-cast microstructure was studied. Results show that microstructure of the sample prepared by the LFEHC process was greatly refined. Microstructures at the border and the center of the ingots were fine, uniform and rosette-shaped.Electromagnetic frequency plays a key role in microstructure refining. Fine and uniform microstructures can be obtained with optimal electromagnetic frequency. In this experiment, under a frequency of 30 Hz the microstructure was the finest and the most uniform.

  7. Is Super-$B$ Sufficiently Superb? -- On the Motivation for a Super-$B$ Factory

    CERN Document Server

    Bigi, Ikaros I

    2004-01-01

    Despite the great success of the $\\Upsilon (4S)$ $B$ factories at KEK and SLAC and the guaranteed addition of high sensitivity measurements on beauty decays to be performed at the Tevatron and LHC, a strong case can be made for an $e^+e^-$ Super-$B$ factory yielding data samples of order $10^{10}$ $B \\bar B$ pairs as a necessity rather than luxury. It has to be justified through its ability to not only establish deviations from the Standard Model, but also diagnose and interpret those in terms of specific features of the New Dynamics. The role to be played by a Super-$B$ factory is thus analogous {\\em and even in parallel} to that of a linear collider. The latter's goal is to provide more detailed information on previously discovered New Physics involved in the electroweak phase transition. Likewise a Super-$B$ factory would provide precision probes for analyzing whether such New Dynamics has an impact on heavy flavour dynamics -- a need particularly manifest if the New Physics is housed under the `big tent' ...

  8. Development of highly sensitive monolithic interferometer for infrared planet search

    Directory of Open Access Journals (Sweden)

    Jiang P.

    2011-07-01

    Full Text Available We present the design, fabrication and testing of a highly sensitive monolithic interferometer for InfraRed Exoplanet Tracker (IR-ET. This interferometer is field-compensated, thermal-stable for working in the wavelength range between 0.8 and 1.35 μm. Two arms of the interferometer creates a fixed delay of 18.0 mm, which is optimized to have the best sensitivity for radial velocity measurements of slow-rotating M dwarfs for planet detection. IR-ET is aiming to reach 3–20 m/s Doppler precision for J<10 M dwarfs in less than 15 min exposures. We plan to conduct a planet survey around hundreds of nearby M dwarfs through collaborations with Astrophysical Research Consortium scientists in 2011–2014.

  9. Polymer-Particle Pressure-Sensitive Paint with High Photostability

    Directory of Open Access Journals (Sweden)

    Yu Matsuda

    2016-04-01

    Full Text Available We propose a novel fast-responding and paintable pressure-sensitive paint (PSP based on polymer particles, i.e. polymer-particle (pp-PSP. As a fast-responding PSP, polymer-ceramic (PC-PSP is widely studied. Since PC-PSP generally consists of titanium (IV oxide (TiO2 particles, a large reduction in the luminescent intensity will occur due to the photocatalytic action of TiO2. We propose the usage of polymer particles instead of TiO2 particles to prevent the reduction in the luminescent intensity. Here, we fabricate pp-PSP based on the polystyrene particle with a diameter of 1 μm, and investigate the pressure- and temperature-sensitives, the response time, and the photostability. The performances of pp-PSP are compared with those of PC-PSP, indicating the high photostability with the other characteristics comparable to PC-PSP.

  10. New application of superconductors: high sensitivity cryogenic light detectors

    CERN Document Server

    Cardani, L; Casali, N; Casellano, M G; Colantoni, I; Coppolecchia, A; Cosmelli, C; Cruciani, A; D'Addabbo, A; Di Domizio, S; Martinez, M; Tomei, C; Vignati, M

    2016-01-01

    In this paper we describe the current status of the CALDER project, which is developing ultra-sensitive light detectors based on superconductors for cryogenic applications. When we apply an AC current to a superconductor, the Cooper pairs oscillate and acquire kinetic inductance, that can be measured by inserting the superconductor in a LC circuit with high merit factor. Interactions in the superconductor can break the Cooper pairs, causing sizable variations in the kinetic inductance and, thus, in the response of the LC circuit. The continuous monitoring of the amplitude and frequency modulation allows to reconstruct the incident energy with excellent sensitivity. This concept is at the basis of Kinetic Inductance Detectors (KIDs), that are characterized by natural aptitude to multiplexed read-out (several sensors can be tuned to different resonant frequencies and coupled to the same line), resolution of few eV, stable behavior over a wide temperature range, and ease in fabrication. We present the results ob...

  11. Technological development for super-high efficiency solar cells. Survey on the commercialization on analysis; Chokokoritsu taiyo denchi no gijutsu kaihatsu. Jitsuyoka kaiseki ni kansuru chosa kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Tatsuta, M. [New Energy and Industrial Technology Development Organization, Tokyo (Japan)

    1994-12-01

    This paper reports the survey results on analysis of super-high efficiency solar cells for practical use in fiscal 1994. (1) On the survey on crystalline compound solar cells, it was pointed out that the present study target is III-V compound semiconductor solar cell, and efficiencies of 36-39% are theoretically expected by use of two-junction cells. (2) On structure of super-high efficiency solar cells of 40%, selection of upper and lower cell materials for multi-junction cells, high-efficiency tandem Si solar cells, and the merit and possibility of light collection operation were surveyed, and their issues were discussed. (3) On physical properties of mixed crystalline semiconductors and characteristic evaluation of solar cells, impurities, trap center, minority carrier life, and applicability of supper lattice structure to high-efficiency solar cells were surveyed. (4) On fabrication technology of compound semiconductor solar cells, various problems of and approaches to electrode formation and antireflection film technologies, the meaning and issues of thin film substrate technology and continuous process, trial calculation of costs, safety, and resource problem were surveyed.

  12. Highly sensitive detection of urinary cadmium to assess personal exposure

    Energy Technology Data Exchange (ETDEWEB)

    Argun, Avni A.; Banks, Ashley M.; Merlen, Gwendolynne; Tempelman, Linda A. [Giner, Inc., 89 Rumford Ave., Newton 02466, MA United States (United States); Becker, Michael F.; Schuelke, Thomas [Fraunhofer USA – CCL, 1449 Engineering Research Ct., East Lansing 48824, MI (United States); Dweik, Badawi M., E-mail: bdweik@ginerinc.com [Giner, Inc., 89 Rumford Ave., Newton 02466, MA United States (United States)

    2013-04-22

    Highlights: ► An electrochemical sensor capable of detecting cadmium at parts-per-billion levels in urine. ► A novel fabrication method for Boron-Doped Diamond (BDD) ultramicroelectrode (UME) arrays. ► Unique combination of BDD UME arrays and a differential pulse voltammetry algorithm. ► High sensitivity, high reproducibility, and very low noise levels. ► Opportunity for portable operation to assess on-site personal exposure. -- Abstract: A series of Boron-Doped Diamond (BDD) ultramicroelectrode arrays were fabricated and investigated for their performance as electrochemical sensors to detect trace level metals such as cadmium. The steady-state diffusion behavior of these sensors was validated using cyclic voltammetry followed by electrochemical detection of cadmium in water and in human urine to demonstrate high sensitivity (>200 μA ppb{sup −1} cm{sup −2}) and low background current (<4 nA). When an array of ultramicroelectrodes was positioned with optimal spacing, these BDD sensors showed a sigmoidal diffusion behavior. They also demonstrated high accuracy with linear dose dependence for quantification of cadmium in a certified reference river water sample from the U.S. National Institute of Standards and Technology (NIST) as well as in a human urine sample spiked with 0.25–1 ppb cadmium.

  13. [Highly sensitive detection technology for biological toxins applying sugar epitopes].

    Science.gov (United States)

    Uzawa, Hirotaka

    2009-01-01

    The Shiga toxin is a highly poisonous protein produced by enterohemorrhagic Escherichia coli O157. This bacterial toxin causes the hemolytic uremic syndrome. Another plant toxin from castor beans, ricin, is also highly toxic. The toxin was used for assassination in London. Recently, there were several cases of postal matter containing ricin. Both toxins are categorized as biological warfare agents by the Centers of Disease Control and Prevention. Conventional detection methods based on the antigen-antibody reaction, PCR and other cell-free assays have been proposed. However, those approaches have drawbacks in terms of sensitivity, analytical time, or stability of the detection reagents. Therefore, development of a facile and sensitive detection method is essential. Here we describe new detection methods applying carbohydrate epitopes as the toxin ligands, which is based on the fact that the toxins bind cell-surface oligosaccharides. Namely, the Shiga toxin has an affinity for globobiosyl (Gb(2)) disaccharide, and ricin binds the beta-D-galactose residue. For Shiga toxin detection, surface plasmon resonance (SPR) was applied. A polyanionic Gb(2)-glycopolymer was designed for this purpose, and it was used for the assembly of Gb(2)-chips using alternating layer-by-layer technology. The method allowed us to detect the toxin at a low concentration of LD(50). A synthetic carbohydrate ligand for ricin was designed and immobilized on the chips. SPR analysis with the chips allows us to detect ricin in a highly sensitive and facile manner (10 pg/ml, 5 min). Our present approaches provide a highly effective way to counter bioterrorism.

  14. Super-B Project Overview

    Energy Technology Data Exchange (ETDEWEB)

    Biagini, M.E.; Boni, R.; Boscolo, M.; Demma, T.; Drago, A.; Guiducci, S.; Raimondi, P.; Tomassini, S.; Zobov, M.; /Frascati; Bertsche, K.; Donald, M.; Nosochkov, Y.; Novokhatski, A.; Seeman, J.; Sullivan, M.; Yocky, G.; Wienands, U.; Wittmer, W.; /SLAC; Koop, I.; Levichev, E.; Nikitin, S.; /Novosibirsk, IYF /KEK, Tsukuba /Pisa U. /CERN

    2010-08-26

    The SuperB project aims at the construction of an asymmetric very high luminosity B-Factory on the Frascati/Tor Vergata (Italy) area, providing a uniquely sensitive probe of New Physics in the flavour sector of the Standard Model. The luminosity goal of 10{sup 36} cm{sup -2} s{sup -1} can be reached with a new collision scheme with 'large Piwinski angle' (LPA) and the use of 'crab waist sextupoles' (CW). A LPA&CW Interaction Region (IR) has been successfully tested at the DA{Phi}NE {Phi}-Factory at LNF-Frascati in 2008. The LPA&CW scheme, together with very low {beta}*, will allow for operation with relatively low beam currents and reasonable bunch length, comparable to those of PEP-II and KEKB. In the High Energy Ring (HER), two spin rotators will bring longitudinally polarized beams into collision at the IP. The lattice has been designed with a very low intrinsic emittance and is quite compact, less than 2 km long. The tight focusing requires the final doublet quadrupoles to be very close to the IP and very compact. A Conceptual Design Report was published in March 2007, and beam dynamics and collective effects R&D studies are in progress in order to publish a Technical Design Report by the end of 2010.

  15. Influence of Smoking on Ultra-High-Frequency Auditory Sensitivity.

    Science.gov (United States)

    Prabhu, Prashanth; Varma, Gowtham; Dutta, Kristi Kaveri; Kumar, Prajwal; Goyal, Swati

    2017-04-01

    In this study, an attempt was made to determine the effect of smoking on ultra-high-frequency auditory sensitivity. The study also attempted to determine the relationship between the nature of smoking and ultra-high-frequency otoacoustic emissions (OAEs) and thresholds. The study sample included 25 smokers and 25 non-smokers. A detailed history regarding their smoking habits was collected. High-frequency audiometric thresholds and amplitudes of high-frequency distortion-product OAEs were analyzed for both ears from all participants. The results showed that the ultra-high-frequency thresholds were elevated and that there was reduction in the amplitudes of ultra-high-frequency OAEs in smokers. There was an increased risk of auditory damage with chronic smoking. The study results highlight the application of ultra-high-frequency OAEs and ultra-high-frequency audiometry for the early detection of auditory impairment. However, similar studies should be conducted on a larger population for better generalization of the results.

  16. A Statistical study of the Doppler spectral width of high-latitude ionospheric F-region echoes recorded with SuperDARN coherent HF radars

    Directory of Open Access Journals (Sweden)

    J.-P. Villain

    Full Text Available The HF radars of the Super Dual Auroral Radar Network (SuperDARN provide measurements of the E × B drift of ionospheric plasma over extended regions of the high-latitude ionosphere. We have conducted a statistical study of the associated Doppler spectral width of ionospheric F-region echoes. The study has been conducted with all available radars from the Northern Hemisphere for 2 specific periods of time. Period 1 corresponds to the winter months of 1994, while period 2 covers October 1996 to March 1997. The distributions of data points and average spectral width are presented as a function of Magnetic Latitude and Magnetic Local Time. The databases are very consistent and exhibit the same features. The most stringent features are: a region of very high spectral width, collocated with the ionospheric LLBL/cusp/mantle region; an oval shaped region of high spectral width, whose equator-ward boundary matches the poleward limit of the Holzworth and Meng auroral oval. A simulation has been conducted to evaluate the geometrical and instrumental effects on the spectral width. It shows that these effects cannot account for the observed spectral features. It is then concluded that these specific spectral width characteristics are the signature of ionospheric/magnetospheric coupling phenomena.

    Key words. Ionosphere (auroral ionosphere; ionosphere-magnetosphere interactions; ionospheric irregularities

  17. Braking materials for emergency stop device of super high speed elevator (810 m/min); 810 m/min erebeta hijo tome sochiyo masatsuzai

    Energy Technology Data Exchange (ETDEWEB)

    Okada, R.; Yamada, T.; Sugahara, J. [Hitachi Ltd., Tokyo (Japan)

    1995-04-20

    Accompanied with a super multistoried building, making the elevator a higher speed is essential and it requires for a performance rise not only on drive unit and control unit, but also on safety device as well, as for especially an emergency stop device to get the cage, which has a kinetic energy proportional to the square of speed, stopped, its performance improvement is indispensable. Because it was anticipated that a braking would become difficult with a speed exceeding 800 m/min by using the iron system materials centering around cast iron used conventionally, an emergency stop device using the special ceramics as a friction material has been developed. In order to develop an elevator with a super high speed of 810 m/min this time, a development of the friction material for emergency stop device, which can brake stably the cage with a kinetic energy substantially exceeding the conventional value, has been advanced. As a result, a strength drop at a high temperature was prevented by adding Cr, Ni and P, and moreover a cast iron with 1,5 times in mean friction coefficient and about 1/10 in specific abrasive quantity compared with FC 250 was developed, and furthermore an emergency stop device with a high performance, which guarantees more than 3 times of braking energy in the emergency stop device of elevator with a speed of 540 m/min, was realized. 5 refs., 8 figs., 1 tab.

  18. Broadband finite-pulse radio-frequency-driven recoupling (fp-RFDR) with (XY8)4(1) super-cycling for homo-nuclear correlations in very high magnetic fields at fast and ultra-fast MAS frequencies.

    Science.gov (United States)

    Shen, Ming; Hu, Bingwen; Lafon, Oliver; Trébosc, Julien; Chen, Qun; Amoureux, Jean-Paul

    2012-10-01

    We demonstrate that inter-residue (13)C-(13)C proximities (of about 380 pm) in uniformly (13)C-labeled proteins can be probed by applying robust first-order recoupling during several milliseconds in single-quantum single-quantum dipolar homo-nuclear correlation (SQ-SQ D-HOMCOR) 2D experiments. We show that the intensity of medium-range homo-nuclear correlations in these experiments is enhanced using broadband first-order finite-pulse radio-frequency-driven recoupling (fp-RFDR) NMR sequence with a nested (XY8)4(1) super-cycling. The robustness and the efficiency of the fp-RFDR-(XY8)4(1) method is demonstrated at high magnetic field (21.1T) and high Magic-Angle Spinning (MAS) speeds (up to 60 kHz). The introduced super-cycling, formed by combining phase inversion and a global four-quantum phase cycle, improves the robustness of fp-RFDR to (i) chemical shift anisotropy (CSA), (ii) spread in isotropic chemical shifts, (iii) rf-inhomogeneity and (iv) hetero-nuclear dipolar couplings for long recoupling times. We show that fp-RFDR-(XY8)4(1) is efficient sans (1)H decoupling, which is beneficial for temperature-sensitive biomolecules. The efficiency and the robustness of fp-RFDR-(XY8)4(1) is investigated by spin dynamics numerical simulations as well as solid-state NMR experiments on [U-(13)C]-L-histidine·HCl, a tetra-peptide (Fmoc-[U-(13)C,(15)N]-Val-[U-(13)C,(15)N]-Ala-[U-(13)C,(15)N]-Phe-Gly-t-Boc) and Al(PO(3))(3).

  19. Ultrathin plasmonic nanogratings for rapid and highly-sensitive detection

    CERN Document Server

    Zeng, Beibei; Bartoli, Filbert J

    2014-01-01

    We developed a nanoplasmonic sensor platform employing the extraordinary optical properties of one-dimensional nanogratings patterned on 30nm-thick ultrathin Ag films. Excitation of Fano resonances in the ultrathin Ag nanogratings results in transmission spectra with high amplitude, large contrast, and narrow bandwidth, making them well-suited for rapid and highly-sensitive sensing applications. The ultrathin nanoplasmonic sensor chip was integrated with a polydimethylsiloxane (PDMS) microfluidic channel, and the measured refractive index resolution was found to be 1.46x10-6 refractive index units (RIU) with a high temporal resolution of 1 sec. This compares favorably with commercial prism-based surface plasmon resonance sensors, but is achieved using a more convenient collinear transmission geometry and a significantly smaller sensor footprint of 50x50um2. In addition, an order-of-magnitude improvement in the temporal and spatial resolutions was achieved relative to state-of-the-art nanoplasmonic sensors, fo...

  20. Potential programs for high sensitivity FIR spectroscopy with SPICA

    CERN Document Server

    Spinoglio, L; Saraceno, P; Spinoglio, Luigi; Giorgio, Anna Maria Di; Saraceno, Paolo

    2006-01-01

    We discuss the potential of high sensitivity mid-IR and far-IR spectroscopy to proof the physical properties of active nuclei and starburst regions of local and distant galaxies. For local galaxies, it will be possible to map the discs and ISM through the low ionization ionic lines and a variety of molecular tracers, such as OH, H2O and high-J CO. At increasing distance, most of the ionic nebular lines (typical of stars and AGNs) are shifted into the FIR, making possible to compare the observed spectra with those predicted by different evolutionary scenarios. At the very high redshift of 10-15, sensitive mid-to-far-IR spectrometers, such as those planned to be at the focal plane of the future SPICA mision, could be adequate to detect the H recombination lines excited in the HII regions around population III stars, if these stars happened to reside in large clusters of more than 10^5 members.

  1. High-sensitivity piezoelectric perovskites for magnetoelectric composites

    Science.gov (United States)

    Amorín, Harvey; Algueró, Miguel; Campo, Rubén Del; Vila, Eladio; Ramos, Pablo; Dollé, Mickael; Romaguera-Barcelay, Yonny; Cruz, Javier Pérez De La; Castro, Alicia

    2015-01-01

    A highly topical set of perovskite oxides are high-sensitivity piezoelectric ones, among which Pb(Zr,Ti)O3 at the morphotropic phase boundary (MPB) between ferroelectric rhombohedral and tetragonal polymorphic phases is reckoned a case study. Piezoelectric ceramics are used in a wide range of mature, electromechanical transduction technologies like piezoelectric sensors, actuators and ultrasound generation, to name only a few examples, and more recently for demonstrating novel applications like magnetoelectric composites. In this case, piezoelectric perovskites are combined with magnetostrictive materials to provide magnetoelectricity as a product property of the piezoelectricity and piezomagnetism of the component phases. Interfaces play a key issue, for they control the mechanical coupling between the piezoresponsive phases. We present here main results of our investigation on the suitability of the high sensitivity MPB piezoelectric perovskite BiScO3–PbTiO3 in combination with ferrimagnetic spinel oxides for magnetoelectric composites. Emphasis has been put on the processing at low temperature to control reactions and interdiffusion between the two oxides. The role of the grain size effects is extensively addressed. PMID:27877758

  2. Visual quality of super-high myopia after ICL V4 c implantation in short-term%ICL V4 c矫正超高度近视术后视觉质量的短期观察

    Institute of Scientific and Technical Information of China (English)

    周妍妍; 郑晓龙

    2015-01-01

    目的:短期观察超高度近视患者植入 ICL V4 c术后的视觉质量。  方法:收集植入ICL V4 c的超高度近视患者78例100眼的临床资料,术前近视屈光度数为-11.25~-20.00(-13.25依2.05)D,术前裸眼视力  结果:术后裸眼视力≥0.7者97眼(97%),≥1.0者37眼(37%)。裸眼视力≥术前矫正视力者90眼(90%)。术后1 mo各空间频率的对比敏感度和眩光对比敏感度均明显提高,差异均有统计学意义(均为P  结论:短期内超高度近视患者植入ICL V4 c术后视觉质量得到了明显提高。%AIM:To observe the visual quality of super - high myopia after implantation of the visian implantable collamer lens with centra-flow ( ICL V4c) in the short-term. METHODS:The clinical date of 78 patients (100 eyes) were collected, the preoperative uncorrected visual acuity (UCVA) was below 0. 10, spherical refraction was-13.25±2.05(-11.25 ~ -20.00)D. The preoperative and postoperative refrative condition, wavefront aberration, visual acuity and contrast sensitivity were examined. RESULTS: The postoperative UCVA in 97 eyes ( 97%) were equal to or more than 0. 7. Thirty-seven eyes (37%) were equal to or more than 1. 0. Both the contrast sensitivity and glare contrast sensitivity under high spatial frequency were increased at postoperative 1mo, there were statistical differences (all P CONCLUSION: The visual quality of super - high myopia after implantation of ICL V4c was improved obviously in short-term.

  3. High-Sensitivity Measurement of Density by Magnetic Levitation.

    Science.gov (United States)

    Nemiroski, Alex; Kumar, A A; Soh, Siowling; Harburg, Daniel V; Yu, Hai-Dong; Whitesides, George M

    2016-03-01

    This paper presents methods that use Magnetic Levitation (MagLev) to measure very small differences in density of solid diamagnetic objects suspended in a paramagnetic medium. Previous work in this field has shown that, while it is a convenient method, standard MagLev (i.e., where the direction of magnetization and gravitational force are parallel) cannot resolve differences in density mm) because (i) objects close in density prevent each other from reaching an equilibrium height due to hard contact and excluded volume, and (ii) using weaker magnets or reducing the magnetic susceptibility of the medium destabilizes the magnetic trap. The present work investigates the use of weak magnetic gradients parallel to the faces of the magnets as a means of increasing the sensitivity of MagLev without destabilization. Configuring the MagLev device in a rotated state (i.e., where the direction of magnetization and gravitational force are perpendicular) relative to the standard configuration enables simple measurements along the axes with the highest sensitivity to changes in density. Manipulating the distance of separation between the magnets or the lengths of the magnets (along the axis of measurement) enables the sensitivity to be tuned. These modifications enable an improvement in the resolution up to 100-fold over the standard configuration, and measurements with resolution down to 10(-6) g/cm(3). Three examples of characterizing the small differences in density among samples of materials having ostensibly indistinguishable densities-Nylon spheres, PMMA spheres, and drug spheres-demonstrate the applicability of rotated Maglev to measuring the density of small (0.1-1 mm) objects with high sensitivity. This capability will be useful in materials science, separations, and quality control of manufactured objects.

  4. Microsphere Super-resolution Imaging

    CERN Document Server

    Wang, Zengbo

    2015-01-01

    Recently, it was discovered that microsphere can generate super-resolution focusing beyond diffraction limit. This has led to the development of an exciting super-resolution imaging technique -microsphere nanoscopy- that features a record resolution of 50 nm under white lights. Different samples have been directly imaged in high resolution and real time without labelling, including both non-biological (nano devices, structures and materials) and biological (subcellular details, viruses) samples. This chapter reviews the technique, which covers its background, fundamentals, experiments, mechanisms as well as the future outlook.

  5. Serpentine Ultralong Path with Extended Routing (SUPER) High Resolution Traveling Wave Ion Mobility-MS using Structures for Lossless Ion Manipulations

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Liulin; Webb, Ian K.; Garimella, Sandilya V. B.; Hamid, Ahmed M.; Zheng, Xueyun; Norheim, Randolph V.; Prost, Spencer A.; Anderson, Gordon A.; Sandoval, Jeremy A.; Baker, Erin S.; Ibrahim, Yehia M.; Smith, Richard D.

    2017-04-05

    Ion mobility (IM) separations have a broad range of analytical applications, but insufficient resolution limits many applications. Here we report on traveling wave (TW) ion mobility (IM) separations in a Serpentine Ultra-long Path with Extended Routing (SUPER) Structures for Lossless Ion Manipulations (SLIM) module in conjunction with mass spectrometry (MS). The extended routing utilized multiple passes was facilitated by the introduction of a lossless ion switch at the end of the ion path that either directed ions to the MS detector or to another pass through the serpentine separation region, providing theoretically unlimited TWIM path lengths. Ions were confined in the SLIM by rf fields in conjunction with a DC guard bias, enabling essentially lossless TW transmission over greatly extended paths (e.g., ~1094 meters over 81 passes through the 13.5 m serpentine path). In this multi-pass SUPER TWIM provided resolution approximately proportional to the square root of the number of passes (or path length). More than 30-fold higher IM resolution for Agilent tuning mix m/z 622 and 922 ions (~340 vs. ~10) was achieved for 40 passes compared to commercially available drift tube IM and other TWIM-based platforms. An initial evaluation of the isomeric sugars Lacto-N-hexaose and Lacto-N-neohexaose showed the isomeric structures to be baseline resolved, and a new conformational feature for Lacto-N-neohexaose was revealed after 9 passes. The new SLIM SUPER high resolution TWIM platform has broad utility in conjunction with MS and is expected to enable a broad range of previously challenging or intractable separations.

  6. Serpentine Ultralong Path with Extended Routing (SUPER) High Resolution Traveling Wave Ion Mobility-MS using Structures for Lossless Ion Manipulations.

    Science.gov (United States)

    Deng, Liulin; Webb, Ian K; Garimella, Sandilya V B; Hamid, Ahmed M; Zheng, Xueyun; Norheim, Randolph V; Prost, Spencer A; Anderson, Gordon A; Sandoval, Jeremy A; Baker, Erin S; Ibrahim, Yehia M; Smith, Richard D

    2017-04-18

    Ion mobility (IM) separations have a broad range of analytical applications, but insufficient resolution often limits their utility. Here, we report on ion mobility separations in a structures for lossless ion manipulations (SLIM) serpentine ultralong path with extended routing (SUPER) traveling wave (TW) ion mobility (IM) module in conjunction with mass spectrometry (MS). Ions were confined in the SLIM by rf fields in conjunction with a DC guard bias, enabling essentially lossless TW transmission over greatly extended paths. The extended routing utilized multiple passes (e.g., ∼1094 m over 81 passes through the 13.5 m serpentine path) and was facilitated by the introduction of a lossless ion switch that allowed ions to be directed to either the MS detector or for another pass through the serpentine separation region, allowing theoretically unlimited IM path lengths. The multipass SUPER IM-MS provided resolution approximately proportional to the square root of the number of passes (or total path length). More than 30-fold higher IM resolution (∼340 vs ∼10) for Agilent tuning mix m/z 622 and 922 ions was achieved for 40 passes compared to commercially available drift tube IM and other TWIM-based platforms. An initial evaluation of the isomeric sugars lacto-N-hexaose and lacto-N-neohexaose showed the isomeric structures to be baseline resolved, and a new conformational feature for lacto-N-neohexaose was revealed after 9 passes. The new SLIM SUPER high resolution TWIM platform has broad utility in conjunction with MS and is expected to enable a broad range of previously challenging or intractable separations.

  7. High pressure-sensitive gene expression in Lactobacillus sanfranciscensis

    Directory of Open Access Journals (Sweden)

    R.F. Vogel

    2005-08-01

    Full Text Available Lactobacillus sanfranciscensis is a Gram-positive lactic acid bacterium used in food biotechnology. It is necessary to investigate many aspects of a model organism to elucidate mechanisms of stress response, to facilitate preparation, application and performance in food fermentation, to understand mechanisms of inactivation, and to identify novel tools for high pressure biotechnology. To investigate the mechanisms of the complex bacterial response to high pressure we have analyzed changes in the proteome and transcriptome by 2-D electrophoresis, and by microarrays and real time PCR, respectively. More than 16 proteins were found to be differentially expressed upon high pressure stress and were compared to those sensitive to other stresses. Except for one apparently high pressure-specific stress protein, no pressure-specific stress proteins were found, and the proteome response to pressure was found to differ from that induced by other stresses. Selected pressure-sensitive proteins were partially sequenced and their genes were identified by reverse genetics. In a transcriptome analysis of a redundancy cleared shot gun library, about 7% of the genes investigated were found to be affected. Most of them appeared to be up-regulated 2- to 4-fold and these results were confirmed by real time PCR. Gene induction was shown for some genes up-regulated at the proteome level (clpL/groEL/rbsK, while the response of others to high hydrostatic pressure at the transcriptome level seemed to differ from that observed at the proteome level. The up-regulation of selected genes supports the view that the cell tries to compensate for pressure-induced impairment of translation and membrane transport.

  8. "Stereoscopic" 2D super-microporous phosphazene-based covalent organic framework: Design, synthesis and selective sorption towards uranium at high acidic condition.

    Science.gov (United States)

    Zhang, Shuang; Zhao, Xiaosheng; Li, Bo; Bai, Chiyao; Li, Yang; Wang, Lei; Wen, Rui; Zhang, Meicheng; Ma, Lijian; Li, Shoujian

    2016-08-15

    So far, only five primary elements (C, H, O, N and B) and two types of spatial configuration (C2-C4, C6 and Td) are reported to build the monomers for synthesis of covalent organic frameworks (COFs), which have partially limited the route selection for accessing COFs with new topological structure and novel properties. Here, we reported the design and synthesis of a new "stereoscopic" 2D super-microporous phosphazene-based covalent organic framework (MPCOF) by using hexachorocyclotriphosphazene (a P-containing monomer in a C3-like spatial configuration) and p-phenylenediamine (a linker). The as-synthesized MPCOF shows high crystallinity, relatively high heat and acid stability and distinctive super-microporous structure with narrow pore-size distributions ranging from 1.0-2.1nm. The results of batch sorption experiments with a multi-ion solution containing 12 co-existing cations show that in the pH range of 1-2.5, MPCOF exhibits excellent separation efficiency for uranium with adsorption capacity more than 71mg/g and selectivity up to record-breaking 92%, and furthermore, an unreported sorption capacity (>50mg/g) and selectivity (>60%) were obtained under strong acidic condition (1M HNO3). Studies on sorption mechanism indicate that the uranium separation by MPCOF in acidic solution is realized mainly through both intra-particle diffusion and size-sieving effect.

  9. Rituximab induction therapy in highly sensitized kidney transplant recipients

    Institute of Scientific and Technical Information of China (English)

    YIN Hang; WAN Hao; HU Xiao-peng; LI Xiao-bei; WANG Wei; LIU Hang; REN Liang; ZHANG Xiao-dong

    2011-01-01

    Background The number of highly sensitized patients is rising, and sensitization can lead to renal transplant failure.The present study aimed to investigate the safety and efficacy of renal transplantation following induction therapy with rituximab in highly sensitized kidney transplant recipients.Methods Seven highly sensitized kidney transplant recipients who underwent rituximab therapy from December 2008 to December 2009 were retrospectively analyzed. There were 3 men and 4 women, with a mean age of 38.5 years (range, 21-47 years). The duration of hemodialysis was 3-12 months, with a mean duration of 11 months. For 4 patients,this was the second transplant; the previous graft survival time was 2-11 years, with a mean survival time of 5.8 years. All the female recipients had history of multiple pregnancies, and all patients had previously received blood transfusions. All donors were men, with a mean age of 32.5 years (range, 25-37 years). In 2 of the 7 patients, both class I and class II of panel reactive antibody were high; the remaining 5 patients showed either high in class I or in class II of panel reactive antibody. The mean panel reactive antibody value was 31% for class I and 51% for class II respectively. The donors and the recipients had the same blood type, with low lymphocyte cytotoxicity ranging from 2% to 5%. The human leukocyte antigen (HLA) mismatch numbers were from 2 to 4. All patients received tacrolimus (0.1 mg·kg-1·d-1) and mycophenolate mofetil (750 mg twice per day) orally 3 days prior to surgery. All patients received a single dose of 600 mg rituximab (375 mg/m2) infusion on the day before surgery and polyclonal antibody (antithymocyte globulin) on the day of surgery.Postoperative creatinine, creatinine clearance rate, and occurrence of rejection by pathological biopsy confirmation were monitored.Results No patient had delayed graft function after surgery. Two patients had acute rejection, one on day 7 and the other on day 13 post

  10. Highly sensitive detection of Staphylococcus aureus directly from patient blood.

    Directory of Open Access Journals (Sweden)

    Padmapriya P Banada

    Full Text Available BACKGROUND: Rapid detection of bloodstream infections (BSIs can be lifesaving. We investigated the sample processing and assay parameters necessary for highly-sensitive detection of bloodstream bacteria, using Staphylococcus aureus as a model pathogen and an automated fluidic sample processing-polymerase chain reaction (PCR platform as a model diagnostic system. METHODOLOGY/PRINCIPAL FINDINGS: We compared a short 128 bp amplicon hemi-nested PCR and a relatively shorter 79 bp amplicon nested PCR targeting the S. aureus nuc and sodA genes, respectively. The sodA nested assay showed an enhanced limit of detection (LOD of 5 genomic copies per reaction or 10 colony forming units (CFU per ml blood over 50 copies per reaction or 50 CFU/ml for the nuc assay. To establish optimal extraction protocols, we investigated the relative abundance of the bacteria in different components of the blood (white blood cells (WBCs, plasma or whole blood, using the above assays. The blood samples were obtained from the patients who were culture positive for S. aureus. Whole blood resulted in maximum PCR positives with sodA assay (90% positive as opposed to cell-associated bacteria (in WBCs (71% samples positive or free bacterial DNA in plasma (62.5% samples positive. Both the assays were further tested for direct detection of S. aureus in patient whole blood samples that were contemporaneous culture positive. S. aureus was detected in 40/45 of culture-positive patients (sensitivity 89%, 95% CI 0.75-0.96 and 0/59 negative controls with the sodA assay (specificity 100%, 95% CI 0.92-1. CONCLUSIONS: We have demonstrated a highly sensitive two-hour assay for detection of sepsis causing bacteria like S. aureus directly in 1 ml of whole blood, without the need for blood culture.

  11. Mesoporous Li4Ti5O12 nanoclusters anchored on super-aligned carbon nanotubes as high performance electrodes for lithium ion batteries

    Science.gov (United States)

    Sun, Li; Kong, Weibang; Wu, Hengcai; Wu, Yang; Wang, Datao; Zhao, Fei; Jiang, Kaili; Li, Qunqing; Wang, Jiaping; Fan, Shoushan

    2015-12-01

    Mesoporous lithium titanate (LTO) nanoclusters are in situ synthesized in a network of super aligned carbon nanotubes (SACNTs) via a solution-based method followed by heat treatment in air. In the LTO-CNT composite, SACNTs not only serve as the skeleton to support a binder-free electrode, but also render the composite with high conductivity, flexibility, and mechanical strength. The homogeneously dispersed LTO nanoclusters among the SACNTs allow each LTO grain to effectively access the electrolyte and the conductive network, benefiting both ion and electron transport. By the incorporation of LTO into the CNT network, mechanical reinforcement is also achieved. When serving as a negative electrode for lithium ion batteries, such a robust composite-network architecture provides the electrodes with effective charge transport and structural integrity, leading to high-performance flexible electrodes with high capacity, high rate capability, and excellent cycling stability.Mesoporous lithium titanate (LTO) nanoclusters are in situ synthesized in a network of super aligned carbon nanotubes (SACNTs) via a solution-based method followed by heat treatment in air. In the LTO-CNT composite, SACNTs not only serve as the skeleton to support a binder-free electrode, but also render the composite with high conductivity, flexibility, and mechanical strength. The homogeneously dispersed LTO nanoclusters among the SACNTs allow each LTO grain to effectively access the electrolyte and the conductive network, benefiting both ion and electron transport. By the incorporation of LTO into the CNT network, mechanical reinforcement is also achieved. When serving as a negative electrode for lithium ion batteries, such a robust composite-network architecture provides the electrodes with effective charge transport and structural integrity, leading to high-performance flexible electrodes with high capacity, high rate capability, and excellent cycling stability. Electronic supplementary information

  12. Coumarin-bearing triarylamine sensitizers with high molar extinction coefficient for dye-sensitized solar cells

    Science.gov (United States)

    Zhong, Changjian; Gao, Jianrong; Cui, Yanhong; Li, Ting; Han, Liang

    2015-01-01

    Coumarin unit is introduced into triarylamine and three organic sensitizers are designed and synthesized with triarylamine bearing coumarin moiety as the electron donor, conjugated system containing thiophene unit as the π-bridge, and cyanoacetic acid moiety as the electron acceptor. The light-harvesting capabilities and photovoltaic performance of these dyes are investigated systematically with the comparison of different π-bridges. High molar extinction coefficients are observed in these triarylamine dyes and the photocurrent and photovoltage are increased with the introduction of another thiophene or benzene. Optimal photovoltaic performance (η = 6.24%, Voc = 690 mV, Jsc = 14.33 mA cm-2, and ff = 0.63) is observed in the DSSC based on dye with thiophene-phenyl unit as the π-conjugated bridge under 100 mW cm-2 simulated AM 1.5 G solar irradiation.

  13. Highly Sensitive Assay for Measurement of Arenavirus-cell Attachment.

    Science.gov (United States)

    Klaus, Joseph P; Botten, Jason

    2016-03-02

    Arenaviruses are a family of enveloped RNA viruses that cause severe human disease. The first step in the arenavirus life cycle is attachment of viral particles to host cells. While virus-cell attachment can be measured through the use of virions labeled with biotin, radioactive isotopes, or fluorescent dyes, these approaches typically require high multiplicities of infection (MOI) to enable detection of bound virus. We describe a quantitative (q)RT-PCR-based assay that measures Junin virus strain Candid 1 attachment via quantitation of virion-packaged viral genomic RNA. This assay has several advantages including its extreme sensitivity and ability to measure attachment over a large dynamic range of MOIs without the need to purify or label input virus. Importantly, this approach can be easily tailored for use with other viruses through the use of virus-specific qRT-PCR reagents. Further, this assay can be modified to permit measurement of particle endocytosis and genome uncoating. In conclusion, we describe a simple, yet robust assay for highly sensitive measurement of arenavirus-cell attachment.

  14. Super Rice Breeding in China

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    @@I. Demand for super high yield rice in China   Rice is one of the main staple food in China. The performance of rice sector in production and yield had been very impressive in the last four decades. However, rice production and yield has stagnated since 1990.

  15. A highly sensitive method for quantification of iohexol

    DEFF Research Database (Denmark)

    Schulz, A.; Boeringer, F.; Swifka, J.

    2014-01-01

    lohexol (1-N,3-N-bis(2,3-dihydroxypropyl)-5-IN-(2,3-dihydroxypropyl) acetamide-2,4,6-triiodobenzene1,3-dicarboxamide) is used for accurate determination of the glomerular filtration rate (GFR) in chronic kidney disease (CKD) patients. However, high iohexol amounts might lead to adverse effects in...... in organisms. In order to minimize the iohexol dosage required for the GFR determination in humans, the development of a sensitive quantification method is essential. Therefore, the objective of our preclinical study was to establish and validate a simple and robust liquid...... with a cut-off of 3 kDa. The chromatographic separation was achieved on an analytical Zorbax SB C18 column. The detection and quantification were performed on a high capacity trap mass spectrometer using positive ion ESI in the multiple reaction monitoring (MRM) mode. Furthermore, using real-time polymerase...

  16. Sensitivity study of reliable, high-throughput resolution metricsfor photoresists

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Christopher N.; Naulleau, Patrick P.

    2007-07-30

    The resolution of chemically amplified resists is becoming an increasing concern, especially for lithography in the extreme ultraviolet (EUV) regime. Large-scale screening and performance-based down-selection is currently underway to identify resist platforms that can support shrinking feature sizes. Resist screening efforts, however, are hampered by the absence of reliable resolution metrics that can objectively quantify resist resolution in a high-throughput fashion. Here we examine two high-throughput metrics for resist resolution determination. After summarizing their details and justifying their utility, we characterize the sensitivity of both metrics to two of the main experimental uncertainties associated with lithographic exposure tools, namely: limited focus control and limited knowledge of optical aberrations. For an implementation at EUV wavelengths, we report aberration and focus limited error bars in extracted resolution of {approx} 1.25 nm RMS for both metrics making them attractive candidates for future screening and down-selection efforts.

  17. Correcting systematic errors in high-sensitivity deuteron polarization measurements

    Energy Technology Data Exchange (ETDEWEB)

    Brantjes, N.P.M. [Kernfysisch Versneller Instituut, University of Groningen, NL-9747AA Groningen (Netherlands); Dzordzhadze, V. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Gebel, R. [Institut fuer Kernphysik, Juelich Center for Hadron Physics, Forschungszentrum Juelich, D-52425 Juelich (Germany); Gonnella, F. [Physica Department of ' Tor Vergata' University, Rome (Italy); INFN-Sez. ' Roma tor Vergata,' Rome (Italy); Gray, F.E. [Regis University, Denver, CO 80221 (United States); Hoek, D.J. van der [Kernfysisch Versneller Instituut, University of Groningen, NL-9747AA Groningen (Netherlands); Imig, A. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Kruithof, W.L. [Kernfysisch Versneller Instituut, University of Groningen, NL-9747AA Groningen (Netherlands); Lazarus, D.M. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Lehrach, A.; Lorentz, B. [Institut fuer Kernphysik, Juelich Center for Hadron Physics, Forschungszentrum Juelich, D-52425 Juelich (Germany); Messi, R. [Physica Department of ' Tor Vergata' University, Rome (Italy); INFN-Sez. ' Roma tor Vergata,' Rome (Italy); Moricciani, D. [INFN-Sez. ' Roma tor Vergata,' Rome (Italy); Morse, W.M. [Brookhaven National Laboratory, Upton, NY 11973 (United States); Noid, G.A. [Indiana University Cyclotron Facility, Bloomington, IN 47408 (United States); and others

    2012-02-01

    This paper reports deuteron vector and tensor beam polarization measurements taken to investigate the systematic variations due to geometric beam misalignments and high data rates. The experiments used the In-Beam Polarimeter at the KVI-Groningen and the EDDA detector at the Cooler Synchrotron COSY at Juelich. By measuring with very high statistical precision, the contributions that are second-order in the systematic errors become apparent. By calibrating the sensitivity of the polarimeter to such errors, it becomes possible to obtain information from the raw count rate values on the size of the errors and to use this information to correct the polarization measurements. During the experiment, it was possible to demonstrate that corrections were satisfactory at the level of 10{sup -5} for deliberately large errors. This may facilitate the real time observation of vector polarization changes smaller than 10{sup -6} in a search for an electric dipole moment using a storage ring.

  18. High Sensitivity MEMS Strain Sensor: Design and Simulation

    Directory of Open Access Journals (Sweden)

    Edmond Lou

    2008-04-01

    Full Text Available In this article, we report on the new design of a miniaturized strain microsensor. The proposed sensor utilizes the piezoresistive properties of doped single crystal silicon. Employing the Micro Electro Mechanical Systems (MEMS technology, high sensor sensitivities and resolutions have been achieved. The current sensor design employs different levels of signal amplifications. These amplifications include geometric, material and electronic levels. The sensor and the electronic circuits can be integrated on a single chip, and packaged as a small functional unit. The sensor converts input strain to resistance change, which can be transformed to bridge imbalance voltage. An analog output that demonstrates high sensitivity (0.03mV/me, high absolute resolution (1μe and low power consumption (100μA with a maximum range of ±4000μe has been reported. These performance characteristics have been achieved with high signal stability over a wide temperature range (±50oC, which introduces the proposed MEMS strain sensor as a strong candidate for wireless strain sensing applications under harsh environmental conditions. Moreover, this sensor has been designed, verified and can be easily modified to measure other values such as force, torque…etc. In this work, the sensor design is achieved using Finite Element Method (FEM with the application of the piezoresistivity theory. This design process and the microfabrication process flow to prototype the design have been presented.

  19. HLA-DRB1, -DRB3, -DRB4 and -DRB5 genotyping at a super-high resolution level by long range PCR and high-throughput sequencing.

    Science.gov (United States)

    Ozaki, Y; Suzuki, S; Shigenari, A; Okudaira, Y; Kikkawa, E; Oka, A; Ota, M; Mitsunaga, S; Kulski, J K; Inoko, H; Shiina, T

    2014-01-01

    Super high-resolution single molecule sequence-based typing (SS-SBT) is a human leukocyte antigen (HLA) DNA typing method to the field 4 level of allelic resolution (formerly known as eight-digit typing) to efficiently detect new and null alleles without phase ambiguity by combination of long ranged polymerase chain reaction (PCR) amplification and next-generation sequencing (NGS) technologies. We previously reported the development and application of the SS-SBT method for the eight classical HLA loci, A, B, C, DRB1, DQA1, DQB1, DPA1 and DPB1. In this article, we describe the development of the SS-SBT method for three DRB1 linked loci, DRB3, DRB4 and DRB5 (DRB3/4/5) and characterization of DRB1-DRB3/4/5 haplotype structures to the field 4 level. Locus specific PCR primers for DRB3/4/5 were designed to amplify the gene regions from intron 1 to exon 6 [3' untranslated region (3'UTR)]. In total 20 DRB1 and 13 DRB3/4/5 allele sequences were determined by the SS-SBT to the field 4 level without phase ambiguity using 19 DR51, DR52 and DR53 positive genomic DNA samples obtained from Japanese. Moreover, 18 DRB1-DRB3/4/5 haplotypes were estimated to the field 4 level by the SS-SBT method in contrast to 10 haplotypes estimated by conventional methods to the field 1 level (formerly known as two digit typing). Therefore, DRB1-DRB3/4/5 haplotyping by SS-SBT is expected to provide informative data for improved HLA matching in medical research, transplantation procedures, HLA-related disease studies and human population diversity studies.

  20. Effect of High Efficient Super Plasticizer on Performance of Iron Tailing High-quality Concrete%高效减水剂对铁尾矿高性能混凝土性能的影响

    Institute of Scientific and Technical Information of China (English)

    崔兴兰; 倪文; 刘倩

    2011-01-01

    将北京密云铁尾矿与高炉水淬矿渣、水泥熟料、脱硫石膏通过三段混合磨矿形成胶凝材料,然后将胶凝材料与铁尾矿混合,并加入高效减水剂,制备成高性能混凝土材料,其中铁尾矿总掺量达到70%.固定其它参数与试验条件,改变高效减水剂的种类和掺量,研究高效减水剂对铁尾矿高性能混凝土性能的影响.试验结果表明:聚羧酸系高效减水剂对新拌混凝土的工作性能最有利,掺入UNF一5的硬化混凝土各龄期的抗压强度最高,28 d强度已经达到80 MPa.%The cementitious materials was formed by three steps milling of Miyun iron ore tailings with water quenched high furnace slag, cement clinker and desulfurized gypsum, and then was mixed with iron tailings to prepare high performance concrete by adding high efficient super plasticizer, in which the total content of iron tailings was 70% by weight. The effect of high efficient super plasticizer on the concrete samples was studied by varying the types and dosage of super plasticizers when the experimental conditions and other parameters were fixed. The results showed that polycarboxylate-based super plasticizer has good effects on the workability of fresh concrete. The hardened concrete samples blended with UNF-5 own highest compressive strength at each stage and reach 80 MPa at 28 d.

  1. Highly sensitive flow-injection chemiluminescence determination of pyrogallol compounds

    Science.gov (United States)

    Kanwal, Shamsa; Fu, Xiaohong; Su, Xingguang

    2009-12-01

    A highly sensitive flow-injection chemiluminescent method for the direct determination of pyrogallol compounds has been developed. Proposed method is based on the enhanced effect of pyrogallol compounds on the chemiluminescence signals of KMnO 4-H 2O 2 system in slightly alkaline medium. Three important pyrogallol compounds, pyrogallic acid, gallic acid and tannic acid, have been detected by this method, and the possible mechanism of the CL reaction is also discussed. The proposed method is simple, convenient, rapid (60 samples h -1), and sensitive, has a linear range of 8 × 10 -10 mol L -1 to 1 × 10 -5 mol L -1, for pyrogallic acid, with a detection limit of 6 × 10 -11 mol L -1, 4 × 10 -8 mol L -1 to 5 × 10 -3 mol L -1 for gallic acid with a detection limit of 9 × 10 -10 mol L -1, and 8 × 10 -8 mol L -1 to 5 × 10 -2 mol L -1 for tannic acid, with a detection limit of 2 × 10 -9 mol L -1, respectively. The relative standard deviation (RSD, n = 15) was 0.8, 1.1 and 1.3% for 5 × 10 -6 mol L -1 pyrogallic acid, gallic acid and tannic acid, respectively. The proposed method was successfully applied to the determination of pyrogallol compounds in tea and coffee samples.

  2. PlanetPol: A Very High Sensitivity Polarimeter

    Science.gov (United States)

    Hough, J. H.; Lucas, P. W.; Bailey, J. A.; Tamura, M.; Hirst, E.; Harrison, D.; Bartholomew-Biggs, M.

    2006-09-01

    We have built and used on several occasions an optical broadband stellar polarimeter, PlanetPol, which employs photoelastic modulators and avalanche photodiodes and achieves a photon-noise-limited sensitivity of at least 1 in 106 in fractional polarization. Observations of a number of polarized standards taken from the literature show that the accuracy of polarization measurements is ~1%. We have developed a method for accurately measuring the polarization of altitude-azimuth mounted telescopes by observing bright nearby stars at different parallactic angles, and we find that the on-axis polarization of the William Herschel Telescope is typically ~15 × 10-6, measured with an accuracy of a few parts in 107. The nearby stars (distance less than 32 pc) are found to have very low polarizations, typically a few ×10-6, indicating that very little interstellar polarization is produced close to the Sun and that their intrinsic polarization is also low. Although the polarimeter can be used for a wide range of astronomy, the very high sensitivity was set by the goal of detecting the polarization signature of unresolved extrasolar planets.

  3. Kinetics of Highly Sensitive Troponin T after Cardiac Surgery

    Directory of Open Access Journals (Sweden)

    Amr S. Omar

    2015-01-01

    Full Text Available Perioperative myocardial infarction (PMI confers a considerable risk in cardiac surgery settings; finding the ideal biomarker seems to be an ideal goal. Our aim was to assess the diagnostic accuracy of highly sensitive troponin T (hsTnT in cardiac surgery settings and to define a diagnostic level for PMI diagnosis. This was a single-center prospective observational study analyzing data from all patients who underwent cardiac surgeries. The primary outcome was the diagnosis of PMI through a specific level. The secondary outcome measures were the lengths of mechanical ventilation (LOV, stay in the intensive care unit (LOSICU, and hospitalization. Based on the third universal definition of PMI, patients were divided into two groups: no PMI (Group I and PMI (Group II. Data from 413 patients were analyzed. Nine patients fulfilled the diagnostic criteria of PMI, while 41 patients were identified with a 5-fold increase in their CK-MB (≥120 U/L. Using ROC analysis, a hsTnT level of 3,466 ng/L or above showed 90% sensitivity and 90% specificity for the diagnosis of PMI. Secondary outcome measures in patients with PMI were significantly prolonged. In conclusion, the hsTnT levels detected here paralleled those of CK-MB and a cut-off level of 3466 ng/L could be diagnostic of PMI.

  4. Development of a New, High Sensitivity 2000 kg Mechanical Balance.

    Science.gov (United States)

    Wang, Jian

    2017-04-13

    Mass measurement of more than 500 kg on an electronic mass comparator has no better repeatability and linearity of measurement for meeting the calibration requirement of over class F1 weights from pharmacy and power generation plants. For this purpose, a new 2000 kg mechanical balance was developed by the National Institute of Metrology (NIM). The advantages of measurement of more than 500 kg on a new 2000 kg mechanical balance are introduced in the paper. In order to obtain high measurement uncertainty, four vertical forces of two sides of beam are measured and used as reference for adjustment of the beam position. Laser displacement sensors in the indication system are more effective for decreasing reading errors caused by human vision. To improve the repeatability and sensitivity of the equipment, a synchronous lifting control is designed for synchronously lifting the beam ends along the vertical direction. A counterweight selection system is developed to get any combination of weights in a limited space. The sensitivity of the new mechanical balance for 2000 kg is more than 1.7 parts in 10(-4) rad/g. The extended uncertainties for the mechanical balance of 500 kg, 1000 kg and 2000 kg are 0.47 g, 1.8 g and 3.5 g respectively.

  5. New application of superconductors: High sensitivity cryogenic light detectors

    Science.gov (United States)

    Cardani, L.; Bellini, F.; Casali, N.; Castellano, M. G.; Colantoni, I.; Coppolecchia, A.; Cosmelli, C.; Cruciani, A.; D'Addabbo, A.; Di Domizio, S.; Martinez, M.; Tomei, C.; Vignati, M.

    2017-02-01

    In this paper we describe the current status of the CALDER project, which is developing ultra-sensitive light detectors based on superconductors for cryogenic applications. When we apply an AC current to a superconductor, the Cooper pairs oscillate and acquire kinetic inductance, that can be measured by inserting the superconductor in a LC circuit with high merit factor. Interactions in the superconductor can break the Cooper pairs, causing sizable variations in the kinetic inductance and, thus, in the response of the LC circuit. The continuous monitoring of the amplitude and frequency modulation allows to reconstruct the incident energy with excellent sensitivity. This concept is at the basis of Kinetic Inductance Detectors (KIDs) that are characterized by natural aptitude to multiplexed read-out (several sensors can be tuned to different resonant frequencies and coupled to the same line), resolution of few eV, stable behavior over a wide temperature range, and ease in fabrication. We present the results obtained by the CALDER collaboration with 2×2 cm2 substrates sampled by 1 or 4 Aluminum KIDs. We show that the performances of the first prototypes are already competitive with those of other commonly used light detectors, and we discuss the strategies for a further improvement.

  6. A highly sensitive fiber Bragg grating diaphragm pressure transducer

    Science.gov (United States)

    Allwood, Gary; Wild, Graham; Lubansky, Alex; Hinckley, Steven

    2015-10-01

    In this work, a novel diaphragm based pressure transducer with high sensitivity is described, including the physical design structure, in-depth analysis of optical response to changes in pressure, and a discussion of practical implementation and limitations. A flat circular rubber membrane bonded to a cylinder forms the body of the transducer. A fiber Bragg grating bonded to the center of the diaphragm structure enables the fractional change in pressure to be determined by analyzing the change in Bragg wavelength of the reflected spectra. Extensive evaluation of the physical properties and optical characteristics of the transducer has been performed through experimentation, and modeling using small deformation theory. The results show the transducer has a sensitivity of 0.116 nm/kPa, across a range of 15 kPa. Ultra-low cost interrogation of the optical signal was achieved through the use of an optically mismatched Bragg grating acting as an edge filter to convert the spectral change into an intensity change. A numerical model of the intensity based interrogation was implemented in order to validate the experimental results. Utilizing this interrogation technique and housing both the sensing and reference Bragg gratings within the main body of the transducer means it is effectively temperature insensitive and easily connected to electronic systems.

  7. Sensitivity of once-shocked, weathered high explosives

    Energy Technology Data Exchange (ETDEWEB)

    Williams, K.L.; Harris, B.W.

    1998-07-01

    Effects caused by stimulating once-shocked, weathered high explosives (OSW-HE) are investigated. The sensitivity of OSW-HE to mechanical stimuli was determined using standard industry tests. Some initial results are given. Pieces of OSW-HE were collected from active and inactive firing sites and from an area surrounding a drop tower at Los Alamos where skid and spigot tests were done. Samples evaluated were cast explosives or plastic bonded explosive (PBX) formulations containing cyclotrimethylenetrinitramine (RDX), cyclotetramethylene tetranitramine (HMX), 2,4,6-trinitrotoluene (TNT), mock or inert HE [tris(beta-chloroethyl)phosphate (CEF)], barium nitrate, cyanuric acid, talc, and Kel-F. Once-shocked, weathered LX-10 Livermore explosive [HMX/Viton A, (95/5 wt %)], PBX 9011 [HMX/Estane, (90/10 wt %)], PBX 9404 [HMX/nitrocellulose, tris(beta-chloroethyl) phosphate, (94/3/3 wt %)], Composition B or cyclotol (TNT/RDX explosives), and PBX 9007 (90% RDX, 9.1% styrene, 0.5% dioctyl phthalate, and 0.45 resin) were subjected to the hammer test, the drop-weight impact sensitivity test, differential thermal analysis (DTA), the spark test, the Henkin`s critical temperature test, and the flame test. Samples were subjected to remote, wet cutting and drilling; remote, liquid-nitrogen-cooled grinding and crushing; and scanning electron microscope (SEM) surface analyses for morphological changes.

  8. Luminescent Lanthanide Reporters for High-Sensitivity Novel Bioassays.

    Energy Technology Data Exchange (ETDEWEB)

    Anstey, Mitchell R.; Fruetel, Julia A.; Foster, Michael E.; Hayden, Carl C.; Buckley, Heather L.; Arnold, John

    2013-09-01

    Biological imaging and assay technologies rely on fluorescent organic dyes as reporters for a number of interesting targets and processes. However, limitations of organic dyes such as small Stokes shifts, spectral overlap of emission signals with native biological fluorescence background, and photobleaching have all inhibited the development of highly sensitive assays. To overcome the limitations of organic dyes for bioassays, we propose to develop lanthanide-based luminescent dyes and demonstrate them for molecular reporting applications. This relatively new family of dyes was selected for their attractive spectral and chemical properties. Luminescence is imparted by the lanthanide atom and allows for relatively simple chemical structures that can be tailored to the application. The photophysical properties offer unique features such as narrow and non-overlapping emission bands, long luminescent lifetimes, and long wavelength emission, which enable significant sensitivity improvements over organic dyes through spectral and temporal gating of the luminescent signal.Growth in this field has been hindered due to the necessary advanced synthetic chemistry techniques and access to experts in biological assay development. Our strategy for the development of a new lanthanide-based fluorescent reporter system is based on chelation of the lanthanide metal center using absorbing chromophores. Our first strategy involves "Click" chemistry to develop 3-fold symmetric chelators and the other involves use of a new class of tetrapyrrole ligands called corroles. This two-pronged approach is geared towards the optimization of chromophores to enhance light output.

  9. On comparison of schemes for air-conditioners in some super-high-rise office buildings%某超高层办公楼空调方案比选

    Institute of Scientific and Technical Information of China (English)

    杨帆; 张博

    2012-01-01

    Under the environment of prosperous development of super-high-rise buildings,the paper analyzes some problems in the design of the air-conditioner system in the super-high-rise buildings according to the features of the super-high-rise buildings and combining some practice experience,compares many schemes,and chooses the most economical and applied air-conditioner system.%在超高层建筑蓬勃发展的环境下,针对超高层建筑特点,结合实践经验,分析了超高层空调系统设计中需注意的问题,并对多种方案进行比选,进而选出最经济、最适用的空调系统。

  10. Super insulating aerogel glazing

    DEFF Research Database (Denmark)

    Schultz, Jørgen Munthe; Jensen, Karsten Ingerslev; Kristiansen, Finn Harken

    2004-01-01

    Monolithic silica aerogel offers the possibility of combining super insulation and high solar energy transmittance, which has been the background for a previous and a current EU project on research and development of monolithic silica aerogel as transparent insulation in windows. Generally, windows...... form the weakest part of the thermal envelope with respect to heat loss coefficient, but on the other hand also play an important role for passive solar energy utilisation. For window orientations other than south, the net energy balance will be close to or below zero. However, the properties...... of aerogel glazing will allow for a positive net energy gain even for north facing vertical windows in a Danish climate during the heating season. This means that high quality daylight can be obtained even with additional energy gain. On behalf of the partners of the two EU projects, results related...

  11. Super-Kamiokande atmospheric neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Moriyama, S. [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Higashi Mozumi, Hida city, Gifu prefecture (Japan)

    2005-08-15

    Results on atmospheric neutrino analysis at Super-Kamiokande I is presented. The whole data set of atmospheric neutrino sample in Super-Kamiokande I is consistently explained with an assumption of pure {nu}{sub {mu}}-{nu}{sub {tau}} oscillations. The allowed range of parameters is 1.5x10{sup -3}<{delta}m{sup 2}<3.4x10{sup -3} eV{sup 2} and sin{sup 2}2{theta}>0.92 at 90% C.L. In the oscillation analysis, we improved the treatment of systematic errors so that they can be considered as independent. This makes possible to find which systematic errors have larger effect on the analysis results. Some sensitivity studies under several assumptions of improvements in systematic errors are presented.

  12. Tunable diameter electrostatically formed nanowire for high sensitivity gas sensing

    Institute of Scientific and Technical Information of China (English)

    Alex Henning; Nandhini Swaminathan; Andrey Godkin; Gil Shalev; Iddo Amit; Yossi Rosenwaks

    2015-01-01

    We report on an electrostatically formed nanowire (EFN)-based sensor with tunable diameters in the range of 16 nm to 46 nm and demonstrate an EFN- based field-effect transistor as a highly sensitive and robust room temperature gas sensor. The device was carefully designed and fabricated using standard integrated processing to achieve the 16 nm EFN that can be used for sensing without any need for surface modification. The effective diameter for the EFN was determined using Kelvin probe force microscopy accompanied by three- dimensional electrostatic simulations. We show that the EFN transistor is capable of detecting 100 parts per million of ethanol gas with bare SiO2.

  13. Magnetic probe array with high sensitivity for fluctuating field.

    Science.gov (United States)

    Kanamaru, Yuki; Gota, Hiroshi; Fujimoto, Kayoko; Ikeyama, Taeko; Asai, Tomohiko; Takahashi, Tsutomu; Nogi, Yasuyuki

    2007-03-01

    A magnetic probe array is constructed to measure precisely the spatial structure of a small fluctuating field included in a strong confinement field that varies with time. To exclude the effect of the confinement field, the magnetic probes consisting of figure-eight-wound coils are prepared. The spatial structure of the fluctuating field is obtained from a Fourier analysis of the probe signal. It is found that the probe array is more sensitive to the fluctuating field with a high mode number than that with a low mode number. An experimental demonstration of the present method is attempted using a field-reversed configuration plasma, where the fluctuating field with 0.1% of the confinement field is successfully detected.

  14. High Efficiency of Dye-Sensitized Solar Cells

    Institute of Scientific and Technical Information of China (English)

    Liyuan Han

    2005-01-01

    @@ 1Introduction Much attention has been paid to the development of dye-sensitized solar cells (DSCs) during the past decade. In general, a DSC comprises a nanocrystalline titanium dioxide (TiO2) electrode modified with a dye fabricated on a transparent conducting oxide (TCO), a platinum (Pt) counter electrode, and an electrolyte solution with a dissolved iodide ion/tri-iodide ion redox couple between the electrodes. Although a DSC using black dye with high efficiency of 10.4%, which was measured by NREL(U. S. A. ), was reported by Graetzel et al. [1], the efficiency of DSCs should be further improved for practical use in comparison with silicon solar cells.

  15. High efficiency solid-state sensitized heterojunction photovoltaic device

    KAUST Repository

    Wang, Mingkui

    2010-06-01

    The high molar extinction coefficient heteroleptic ruthenium dye, NaRu(4,4′-bis(5-(hexylthio)thiophen-2-yl)-2,2′-bipyridine) (4-carboxylic acid-4′-carboxylate-2,2′-bipyridine) (NCS) 2, exhibits certified 5% electric power conversion efficiency at AM 1.5 solar irradiation (100 mW cm-2) in a solid-state dye-sensitized solar cell using 2,2′,7,7′-tetrakis-(N,N-di-pmethoxyphenylamine)-9, 9′-spirobifluorene (spiro-MeOTAD) as the organic hole-transporting material. This demonstration elucidates a class of photovoltaic devices with potential for low-cost power generation. © 2010 Elsevier Ltd. All rights reserved.

  16. Yield and Water Productivity Responses to Irrigation Cut-off Strategies after Fruit Set Using Stem Water Potential Thresholds in a Super-High Density Olive Orchard.

    Science.gov (United States)

    Ahumada-Orellana, Luis E; Ortega-Farías, Samuel; Searles, Peter S; Retamales, Jorge B

    2017-01-01

    An increase in the land area dedicated to super-high density olive orchards has occurred in Chile in recent years. Such modern orchards have high irrigation requirements, and optimizing water use is a priority. Moreover, this region presents low water availability, which makes necessary to establish irrigation strategies to improve water productivity. An experiment was conducted during four consecutive growing seasons (2010-2011 to 2013-2014) to evaluate the responses of yield and water productivity to irrigation cut-off strategies. These strategies were applied after fruit set using midday stem water potential (Ψstem) thresholds in a super-high density olive orchard (cv. Arbequina), located in the Pencahue Valley, Maule Region, Chile. The experimental design was completely randomized with four irrigation cut-off treatments based on the Ψstem thresholds and four replicate plots per treatment (five trees per plot). Similar to commercial growing conditions in our region, the Ψstem in the T1 treatment was maintained between -1.4 and -2.2 MPa (100% of actual evapotranspiration), while T2, T3 and T4 treatments did not receive irrigation from fruit set until they reached a Ψstem threshold of approximately -3.5, -5.0, and -6.0 MPa, respectively. Once the specific thresholds were reached, irrigation was restored and maintained as T1 in all treatments until fruits were harvested. Yield and its components were not significantly different between T1 and T2, but fruit yield and total oil yield, fruit weight, and fruit diameter were decreased by the T3 and T4 treatments. Moreover, yield showed a linear response with water stress integral (SΨ), which was strongly influenced by fruit load. Total oil content (%) and pulp/stone ratio were not affected by the different irrigation strategies. Also, fruit and oil water productivities were significantly greater in T1 and T2 than in the T3 and T4. Moreover, the T2, T3, and T4 treatments averaged 37, 51, and 72 days without

  17. High sensitivity moiré interferometry with compact achromatic interferometry

    Science.gov (United States)

    Czarnek, Robert

    Experimental observations and measurements are the sources of information essential for correct development of mathematical models of real structural materials. Moiré interferometry offers high sensitivity in full-field measurements of in-plane displacements on the surface of a specimen. Although it is a powerful method in experimental stress analysis, it has some shortcomings. One is that existing systems require highly coherent light. The only sufficient source of light for this application is a long cavity laser, which is relatively expensive and at best cumbersome. Another shortcoming is that measurements must be performed in a vibration-free environment, such as that found on a holographic table. These requirements limit the use of existing moiré interferometers to a holographic laboratory. In this paper a modified concept of compensation is presented, which permits the use of a chromatic source of light in a compact moiré system. The compensator provides order in the angles of incident light for each separate wavelength, so that the virtual reference grating created by each wavelength in a continuous spectrum is identical in frequency and spatial position. The result is a virtual reference grating that behaves exactly like that created in coherent light. With this development the use of a laser diode, which is a non-coherent light source of tiny dimensions, becomes practical. The special configuration of the optics that create the virtual grating allows its synchronization with the specimen grating and leads to an interferometer design that is relatively insensitive to the vibrations found in a mechanical testing laboratory. Sensitivity to relative motion is analyzed theoretically. This development provides the oppurtunity to apply moiré interferometry to solid mechanics problems that cannot be studied in an optics laboratory. Experimental verification of the optical concepts is provided. A compact moiré interferometer based on the presented idea was

  18. Calculus super review

    CERN Document Server

    2012-01-01

    Get all you need to know with Super Reviews! Each Super Review is packed with in-depth, student-friendly topic reviews that fully explain everything about the subject. The Calculus I Super Review includes a review of functions, limits, basic derivatives, the definite integral, combinations, and permutations. Take the Super Review quizzes to see how much you've learned - and where you need more study. Makes an excellent study aid and textbook companion. Great for self-study!DETAILS- From cover to cover, each in-depth topic review is easy-to-follow and easy-to-grasp - Perfect when preparing for

  19. Algebra & trigonometry super review

    CERN Document Server

    2012-01-01

    Get all you need to know with Super Reviews! Each Super Review is packed with in-depth, student-friendly topic reviews that fully explain everything about the subject. The Algebra and Trigonometry Super Review includes sets and set operations, number systems and fundamental algebraic laws and operations, exponents and radicals, polynomials and rational expressions, equations, linear equations and systems of linear equations, inequalities, relations and functions, quadratic equations, equations of higher order, ratios, proportions, and variations. Take the Super Review quizzes to see how much y

  20. Scanning Auger microscopy for high lateral and depth elemental sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, E., E-mail: eugenie.martinez@cea.fr [CEA, LETI, MINATEC Campus, 17 rue des Martyrs, 38054 Grenoble Cedex 9 (France); Yadav, P. [CEA, LETI, MINATEC Campus, 17 rue des Martyrs, 38054 Grenoble Cedex 9 (France); Bouttemy, M. [Institut Lavoisier de Versailles, 45 av. des Etats-Unis, 78035 Versailles Cedex (France); Renault, O.; Borowik, Ł.; Bertin, F. [CEA, LETI, MINATEC Campus, 17 rue des Martyrs, 38054 Grenoble Cedex 9 (France); Etcheberry, A. [Institut Lavoisier de Versailles, 45 av. des Etats-Unis, 78035 Versailles Cedex (France); Chabli, A. [CEA, LETI, MINATEC Campus, 17 rue des Martyrs, 38054 Grenoble Cedex 9 (France)

    2013-12-15

    Highlights: •SAM performances and limitations are illustrated on real practical cases such as the analysis of nanowires and nanodots. •High spatial elemental resolution is shown with the analysis of reference semiconducting Al{sub 0.7}Ga{sub 0.3}As/GaAs multilayers. •High in-depth elemental resolution is also illustrated. Auger depth profiling with low energy ion beams allows revealing ultra-thin layers (∼1 nm). •Analysis of cross-sectional samples is another effective approach to obtain in-depth elemental information. -- Abstract: Scanning Auger microscopy is currently gaining interest for investigating nanostructures or thin multilayers stacks developed for nanotechnologies. New generation Auger nanoprobes combine high lateral (∼10 nm), energy (0.1%) and depth (∼2 nm) resolutions thus offering the possibility to analyze the elemental composition as well as the chemical state, at the nanometre scale. We report here on the performances and limitations on practical examples from nanotechnology research. The spatial elemental sensitivity is illustrated with the analysis of Al{sub 0.7}Ga{sub 0.3}As/GaAs heterostructures, Si nanowires and SiC nanodots. Regarding the elemental in-depth composition, two effective approaches are presented: low energy depth profiling to reveal ultra-thin layers (∼1 nm) and analysis of cross-sectional samples.

  1. Antenna design and distribution of the LOFAR super station

    Science.gov (United States)

    Girard, Julien N.; Zarka, Philippe; Tagger, Michel; Denis, Laurent; Charrier, Didier; Konovalenko, Alexander A.; Boone, Frédéric

    2012-01-01

    The Nançay radio astronomy observatory and associated laboratories are developing the concept of a "Super Station" for extending the LOFAR station now installed and operational in Nançay. The LOFAR Super Station (LSS) will increase the number of high sensitivity long baselines, provide short baselines, act as an alternate core, and be a large standalone instrument. It will operate in the low frequency band of LOFAR (15-80 MHz) and extend this range to lower frequencies. Three key developments for the LSS are described here: (i) the design of a specific antenna, and the distribution of such antennas; (ii) at small-scale (analog-phased mini-array); and (iii) at large-scale (the whole LSS).

  2. Laser-engraved carbon nanotube paper for instilling high sensitivity, high stretchability, and high linearity in strain sensors

    KAUST Repository

    Xin, Yangyang

    2017-06-29

    There is an increasing demand for strain sensors with high sensitivity and high stretchability for new applications such as robotics or wearable electronics. However, for the available technologies, the sensitivity of the sensors varies widely. These sensors are also highly nonlinear, making reliable measurement challenging. Here we introduce a new family of sensors composed of a laser-engraved carbon nanotube paper embedded in an elastomer. A roll-to-roll pressing of these sensors activates a pre-defined fragmentation process, which results in a well-controlled, fragmented microstructure. Such sensors are reproducible and durable and can attain ultrahigh sensitivity and high stretchability (with a gauge factor of over 4.2 × 10(4) at 150% strain). Moreover, they can attain high linearity from 0% to 15% and from 22% to 150% strain. They are good candidates for stretchable electronic applications that require high sensitivity and linearity at large strains.

  3. Alemtuzumab induction therapy in highly sensitized kidney transplant recipients

    Institute of Scientific and Technical Information of China (English)

    L(U) Tie-ming; YANG Shun-liang; WU Wei-zhen; TAN Jian-ming

    2011-01-01

    Background Immunosuppression for immunologically high-risk kidney transplant patients usually involves antithymocyte globulin induction with triple drug maintenance therapy. Alemtuzumab, a humanized anti-CD52 antibody,was expected to be a promising induction therapy agent for kidney transplantation. However, currently no consensus is available about its efficacy and safety. This study aimed to evaluate the efficacy and safety of alemtuzumab as immune induction therapy in highly sensitized kidney transplant recipients.Methods In this prospective, open-label, randomized, controlled trial, we enrolled 23 highly immunological risk patients (panel reactive antibody >20%). They were divided into two groups: alemtuzumab group (trial group) and anti-thymocyte globulin (ATG) group (control group). Patients in the alemtuzumab group received intravenous alemtuzumab (15 mg) as a single dose before reperfusion. At the 24th hour post-operation, another dosage of alemtuzumab (15 mg) was given.The control group received a bolus of rabbit ATG (9 mg/kg), which was given 2 hours before kidney transplantation and lasted until the removal of vascular clamps when the anastomoses were completed. Maintenance immunosuppression in both groups comprised standard triple therapy consisting of tacrolimus, prednisone, and mycophenolate mofetil (MMF).Acute rejection (AR) and infection episodes were recorded, and kidney function was monitored during a 2-year follow-up.χ2 test, t test and Kaplan-Meier analysis were performed with SPSS17.0 software.Results Median follow-up was 338 days. In both the alemtuzumab group and ATG group, creatinine and blood urea nitrogen values in surviving recipients were similar (P >0.05). White blood cell counts were significantly reduced in the alemtuzumab group for the most time points up to 6 months (P <0.05). One patient receiving alemtuzumab died for acute myocardial infarction at the 65th day post-operation. Two ATG patients died for severe pulmonary

  4. High-pressure single-crystal X-ray diffraction study on Super Fluorous Phase B up to 7.4 GPa

    Science.gov (United States)

    Kuribayashi, T.; Kojitani, H.; Nagase, T.; Akaogi, M.; Mao, H.; Hemley, R.; Kudoh, Y.

    2008-12-01

    Super hydrous phase B (SUP-B), Mg10Si3O14(OH)4, is known as one of dense hydrous magnesium silicate minerals (DHMS). Also, super fluorous phase B (sup-B-F), Mg10Si3O14F4, was firstly synthesized by Hazen et al. (1997). In the crystal structure of SUP-B-F, F replaces OH in sup-B structure. Therefore, differences of behavior between SUP-B-F and SUP-B under high-pressure conditions directory reflect the effect of hydrogen bonding. In this study, to clarify the behavior of SUP-B-F under high-pressure condition, SUP-B-F was synthesized at 21 GPa and 1400°C conditions using the Kawai type multi anvil apparatus installed in Gakushu-in University. Using a synthesized single-crystal (0.04 × 0.04 × 0.03 mm3), high-pressure single-crystal X-ray diffraction measurements were conducted up to 7.4 GPa with synchrotron radiation. Lattice constants were determined at several pressure points up to 7.4 GPa. The isothermal bulk modulus of SUP-B-F, calculated from the Birch-Murnaghan Equation of State, was 154(2) GPa with a pressure derivative K'=4 (assuming). This value is significantly larger than that of super hydrous phase B (142.8(5) GPa with K"f=5.7 by Crichton et al., 1999). The X-ray reflection intensity data set was collected at 5.0 GPa using the four-circle diffractometer installed at the beam line BL-10A in Photon Factory, Japan. 198 reflections were used for structure refinement (the number of measured reflections is 786). After Lorentz- polarization correction and background reduction were applied for all intensity data, the crystallographic equivalent reflections (Orthorhombic, Pnnm) were averaged. Structure refinement results were R=5.0% and wR2=13.1%, respectively.

  5. The Impact of SuperB on Flavor Physics

    Energy Technology Data Exchange (ETDEWEB)

    Meadows, B.; Blanke, M.; Stocchi, A.; Drutskoy, A.; Cervelli, A.; Giorgi, M.; Lusiani, A.; Perez, A.; Walsh, J.; Hurth, T.; Bevan, A.; Silvestrini, L.; Ciuchini, M.; Tarantino, C.

    2012-02-16

    This report provides a succinct summary of the physics programme of SuperB, and describes that potential in the context of experiments making measurements in flavour physics over the next 10 to 20 years. Detailed comparisons are made with Belle II and LHCb, the other B physics experiments that will run in this decade. SuperB will play a crucial role in defining the landscape of flavour physics over the next 20 years. SuperB is an approved high luminosity e{sup +}e{sup -} collider intended to search for indirect and some direct signs of new physics (NP) at low energy, while at the same time, enabling precision tests of the Standard Model (SM). This experiment will be built at a new laboratory on the Tor Vergata campus near Rome, Italy named after Nicola Cabibbo. The project has been described in a Conceptual Design Report, and more recently by a set of three white papers on the accelerator, detector, and physics programme. The main focus of the physics programme rests in the study of so-called Golden Modes, these are decay channels that provide access to measurements of theoretically clean observables that can provide both stringent constraints on models of NP, and precision tests of the SM. A number of ancillary measurements that remain important include those with observables that may not be theoretically clean, and those that can be used to provide stringent constraints on the SM but are not sensitive to NP. The remainder of this section introduces SuperB before discussing the golden modes for SuperB, precision CKM measurement modes, and an outline of the rest of this report.

  6. 超高层建筑智能化系统若干问题浅析%Analysis on Some Problems about Intelligent Systems in Super High-rise Buildings

    Institute of Scientific and Technical Information of China (English)

    李志涛; 兰海民; 岳远波

    2011-01-01

    结合超高层建筑功能特点和智能化技术应用现状,提出超高层智能化设计要点,旨在探讨和提供适宜此类建筑特点的技术措施。%Combined with the function features and the present situation of intelligent technology in super high-rise buildings, this paper advances the design points of super high-rise buildings, which are aimed at discuss and provide technical measures that suitab

  7. High sensitivity and high resolution element 3D analysis by a combined SIMS–SPM instrument

    Directory of Open Access Journals (Sweden)

    Yves Fleming

    2015-04-01

    Full Text Available Using the recently developed SIMS–SPM prototype, secondary ion mass spectrometry (SIMS data was combined with topographical data from the scanning probe microscopy (SPM module for five test structures in order to obtain accurate chemical 3D maps: a polystyrene/polyvinylpyrrolidone (PS/PVP polymer blend, a nickel-based super-alloy, a titanium carbonitride-based cermet, a reticle test structure and Mg(OH2 nanoclusters incorporated inside a polymer matrix. The examples illustrate the potential of this combined approach to track and eliminate artefacts related to inhomogeneities of the sputter rates (caused by samples containing various materials, different phases or having a non-flat surface and inhomogeneities of the secondary ion extraction efficiencies due to local field distortions (caused by topography with high aspect ratios. In this respect, this paper presents the measured relative sputter rates between PVP and PS as well as in between the different phases of the TiCN cermet.

  8. High-Resolution Imaging of Molecular Gas and Dust in the Antennae (NGC 4038/39) Super Giant Molecular Complexes

    CERN Document Server

    Wilson, C D; Madden, S C; Charmandaris, V

    2000-01-01

    We present new aperture synthesis CO maps of the Antennae (NGC 4038/39) obtained with the Caltech Millimeter Array. These sensitive images show molecular emission associated with the two nuclei and a partial ring of star formation to the west of NGC 4038, as well as revealing the large extent of the extra-nuclear region of star formation (the ``overlap region''), which dominates the CO emission from this system. The largest molecular complexes have masses of 3-6x10^8 M_sun, typically an order of magnitude larger than the largest structures seen to date in more quiescent galaxy disks. The extremely red luminous star clusters identified previously with HST are well-correlated with the CO emission, which supports the conclusion that they are highly embedded young objects rather than old globular clusters. There is an excellent correlation between the CO emission and the 15 micron emission seen with ISO, particularly for the brightest regions. The most massive complexes in the overlap region have similar [NeIII]/...

  9. Phase measurements exhibiting super sensitivity and super resolution features

    DEFF Research Database (Denmark)

    Schäfermeier, Clemens; Jezek, Miroslav; Gehring, Tobias

    2016-01-01

    By using an optical squeezed state and a post-processed homodyne detection scheme we show that phase measurements can overcome Rayleigh's resolution criterion and beat the quantum shot noise limit simultaneously......By using an optical squeezed state and a post-processed homodyne detection scheme we show that phase measurements can overcome Rayleigh's resolution criterion and beat the quantum shot noise limit simultaneously...

  10. Innovative nanostructures for highly sensitive vibrational biosensing (Conference Presentation)

    Science.gov (United States)

    Popp, Juergen; Mayerhöfer, Thomas; Cialla-May, Dana; Weber, Karina; Huebner, Uwe

    2016-03-01

    Employing vibrational spectroscopy (IR-absorption and Raman spectroscopy) allows for the labelfree detection of molecular specific fingerprints of inorganic, organic and biological substances. The sensitivity of vibrational spectroscopy can be improved by several orders of magnitude via the application of plasmonic active surfaces. Within this contribution we will discuss two such approaches, namely surface enhanced Raman spectroscopy (SERS) as well as surface enhanced IR absorption (SEIRA). It will be shown that SERS using metal colloids as SERS active substrate in combination with a microfluidic lab-on-a-chip (LOC) device enables high throughput and reproducible measurements with highest sensitivity and specificity. The application of such a LOC-SERS approach for therapeutic drug monitoring (e.g. quantitative detection of antibiotics in a urine matrix) will be presented. Furthermore, we will introduce innovative bottom-up strategies to prepare SERS-active nanostructures coated with a lipophilic sensor layer as one-time use SERS substrates for specific food analysis (e.g. quantitative detection of toxic food colorants). The second part of this contribution presents a slit array metamaterial perfect absorber for IR sensing applications consisting of a dielectric layer sandwiched between two metallic layers of which the upper layer is perforated with a periodic array of slits. Light-matter interaction is greatly amplified in the slits, where also the analyte is concentrated, as the surface of the substrate is covered by a thin silica layer. Thus, already small concentrations of analytes down to a monolayer can be detected by refractive index sensing and identified by their spectral fingerprints with a standard mid-infrared lab spectrometer.

  11. Conducting polymer nanofibers for high sensitivity detection of chemical analytes.

    Science.gov (United States)

    Kumar, Abhishek; Leshchiner, Ignaty; Nagarajan, Subhalakshmi; Nagarajan, Ramaswamy; Kumar, Jayant

    2008-03-01

    Possessing large surface area materials is vital for high sensitivity detection of analyte. We report a novel, inexpensive and simple technique to make high surface area sensing interfaces using electrospinning. Conducting polymers (CP) nanotubes were made by electrospinning a solution of a catalyst (ferric tosylate) along with poly (lactic acid), which is an environment friendly biodegradable polymer. Further vapor deposition polymerization of the monomer ethylenedioxy thiophene (EDOT) on the nanofiber surface yielded poly (EDOT) covered fibers. X-ray photo electron spectroscopy (XPS) study reveals the presence of PEDOT predominantly on the surface of nanofibers. Conducting nanotubes had been received by dissolving the polymer in the fiber core. By a similar technique we had covalently incorporated fluorescent dyes on the nanofiber surface. The materials obtained show promise as efficient sensing elements. UV-Vis characterization confirms the formation of PEDOT nanotubes and incorporation of chromophores on the fiber surface. The morphological characterization was carried out using scanning electron microscopy (SEM) and transmission electron microscopy (TEM).

  12. Two-stage laparoscopic biliopancreatic diversion with duodenal switch as treatment of high-risk super-obese patients: analysis of complications.

    Science.gov (United States)

    Silecchia, G; Rizzello, M; Casella, G; Fioriti, M; Soricelli, E; Basso, N

    2009-05-01

    The aim of this study is to retrospectively analyze the incidence of complications after two-stage laparoscopic biliopancreatic diversion with duodenal switch (Lap BPD-DS) in high-risk super-obese patients and explore the possible predictive factors of specific complications after laparoscopic sleeve gastrectomy (SG). High-risk patients--body mass index (BMI) > 50 kg/m(2) with at least two major comorbidities: type 2 diabetes, obstructive sleep apnea syndrome (OSAS), hypertension--undergoing two-stage laparoscopic BPD-DS were retrospectively analysed. The SG pouch volume was 100-150 ml; in the second stage, the common channel and the alimentary loop were 100 cm and 150 cm, respectively. Eighty-seven patients (50 female, 57.5%) underwent SG (two open). The mean age was 41.8 +/- 10.22 years with BMI of 55.2 +/- 6.69 kg/m(2). Four patients had Prader-Willy syndrome. Fourteen (16.46%) patients (6 female, 42.8%) had postoperative complications such as bleeding, fistula, pulmonary embolism, transitory acute renal failure, and abdominal abscess. One patient died at postoperative day 5 of pulmonary embolism. One patient was reoperated for hemoperitoneum by laparoscopy. The risk of complications after SG was lower in patients where reinforcement of the suture line was used (0.492), while it was higher in men (1.780). Neither difference was statistically significant [p = not significant (NS)]. After 9-24 months, 27 patients (BMI 43 +/- 8 kg/m(2)) underwent a second stage of BPD-DS (two open). Major postoperative complications were registered in eight patients (29.6%): three bleeding, four duodeno-ileal stenosis and one rhabdomyolysis. Two cases of internal hernia required laparoscopic reoperation. The reoperation rate was 1/85 (1.2%) after SG and 2/27 (7.4%) after second stage. Complications after SG greatly decrease after the learning curve period and can be successfully managed without need of reoperation. Suture-line reinforcement, at least selectively in the middle

  13. Accelerated Sensitivity Analysis in High-Dimensional Stochastic Reaction Networks.

    Science.gov (United States)

    Arampatzis, Georgios; Katsoulakis, Markos A; Pantazis, Yannis

    2015-01-01

    Existing sensitivity analysis approaches are not able to handle efficiently stochastic reaction networks with a large number of parameters and species, which are typical in the modeling and simulation of complex biochemical phenomena. In this paper, a two-step strategy for parametric sensitivity analysis for such systems is proposed, exploiting advantages and synergies between two recently proposed sensitivity analysis methodologies for stochastic dynamics. The first method performs sensitivity analysis of the stochastic dynamics by means of the Fisher Information Matrix on the underlying distribution of the trajectories; the second method is a reduced-variance, finite-difference, gradient-type sensitivity approach relying on stochastic coupling techniques for variance reduction. Here we demonstrate that these two methods can be combined and deployed together by means of a new sensitivity bound which incorporates the variance of the quantity of interest as well as the Fisher Information Matrix estimated from the first method. The first step of the proposed strategy labels sensitivities using the bound and screens out the insensitive parameters in a controlled manner. In the second step of the proposed strategy, a finite-difference method is applied only for the sensitivity estimation of the (potentially) sensitive parameters that have not been screened out in the first step. Results on an epidermal growth factor network with fifty parameters and on a protein homeostasis with eighty parameters demonstrate that the proposed strategy is able to quickly discover and discard the insensitive parameters and in the remaining potentially sensitive parameters it accurately estimates the sensitivities. The new sensitivity strategy can be several times faster than current state-of-the-art approaches that test all parameters, especially in "sloppy" systems. In particular, the computational acceleration is quantified by the ratio between the total number of parameters over the

  14. Highly biocompatible chitosan with super paramagnetic calcium ferrite (CaFe2O4) nanoparticle for the release of ampicillin.

    Science.gov (United States)

    Bilas, Ram; Sriram, K; Maheswari, P Uma; Sheriffa Begum, K M Meera

    2017-04-01

    The CaFe2O4 nanoparticles (CFNP) were synthesized using the solution combustion method. The CFNP-chitosan-ampicillin was prepared by the ionic gelation method using tripolyphosphate (TPP). The CFNP, chitosan-CFNP, chitosan-CFNP-ampicillin materials were characterized by XRD, FT-IR and TGA analysis in order to evaluate the particle nature and size, the presence of functional groups and their thermal stability. The FESEM and EDAX analysis were performed to understand the surface morphology of the materials and the presence of CFNP in the material, respectively. The vibrating sample magnetometer (VSM) analysis was performed to analyze the magnetic property of the chitosan-CFNP material. The squareness value of 0.1733 obtained by VSM measurements indicates the super paramagnetic nature of chitosan-CFNP. Taguchi orthogonal array method was applied to identify the significant impacting parameters for maximizing the drug encapsulation of chitosan-CFNP. The drug release studies showed that the drug was released rapidly in acidic medium as compared to the basic or neutral medium. The drug release kinetic data were fitted with different linear kinetic model equations and the best fit was obtained with Korsmeyer-Peppas model. The model drug ampicillin release from chitosan-CFNP was tested against staphylococcus epidermis bacteria through disc diffusion method for checking biocompatibility and antibacterial activity.

  15. The SuperNEMO double beta decay experiment

    OpenAIRE

    Nasteva, Irina; Collaboration, for the SuperNEMO

    2007-01-01

    The SuperNEMO project studies the feasibility of employing a technique of tracking plus calorimetry to search for neutrinoless double beta decay in 100 kg of enriched isotopes. It aims to reach an effective neutrino mass sensitivity of 50 meV. The current status of the SuperNEMO R&D programme is described, focusing on the main areas of improvement.

  16. 超高层建筑钢结构测量技术%Steel structure measurement technology of super-high-rise building

    Institute of Scientific and Technical Information of China (English)

    李健良

    2016-01-01

    以广州越秀金融大厦为例,从测量控制点引测、施工测量放样、钢结构焊接后检测等方面,对该项目的钢结构安装测量施工技术进行了论述,为今后超高层建筑的钢结构测量提供了参考。%Taking Yuexiu finance mansion in Guangzhou as an example,starting from aspects of measurement control point leading measurement, construction sampling and steel structure detection after wielding,the thesis discusses the steel structure installation measurement construction technologies,which has provided some guidance for steel structure measurement of super-high-rise building.

  17. Temperature field in the hot-top during casting a new super-high strength Al-Zn-Mg-Cu alloy by low frequency electromagnetic process

    Directory of Open Access Journals (Sweden)

    Yubo ZUO

    2005-08-01

    Full Text Available The billets of a new super-high strength Al-Zn-Mg-Cu alloy in 200 mm diameter were produced by the processed of low frequency electromagnetic casting (LFEC and conventional direct chill(DCcasting, respectively. The effects of low frequency electromagnetic field on temperature field of the melt in the hot-top were investigated by temperature thermocouples into the casting during the processes. The results show that during LFEC process the temperature field in the melt applying the hot-top is very uniform, which is helpful to reduce the difference of thermal gradients between the surface and the center, and then to reduce the thermal stress and to eliminate casting crack.

  18. Temperature field in the hot-top during casting a new super-high strength Al-Zn-Mg-Cu alloy by low frequency electromagnetic process

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    The billets of a new super-high strength Al-Zn-Mg-Cu alloy in 200mm diameter were produced by the processes of low frequency electromagnetic casting (LFEC) and conventional direct chill (DC) casting, respectively. The effects of low frequency electromagnetic field on temperature field of the melt in the hot-top were investigated by temperature measurement method. Temperature curves were measured from the surface to the center of the billets by locating type K thermocouples into the casting during the processes. The results show that during LFEC process the temperature field in the melt applying the hot-top is very uniform, which is helpful to reduce the difference of thermal gradients between the surface and the center, and then to reduce the thermal stress and to eliminate casting crack.

  19. Discussion on sustainable management of super high-rise building%谈超高层建筑的可持续化管理

    Institute of Scientific and Technical Information of China (English)

    陆美玲

    2015-01-01

    概括了中国超高层建筑的设计新理念,结合上海中心大厦的建造实例,分别对智能化建筑管理、节能管理、安全与服务管理等可持续化管理经验进行阐述,以期为未来使用者提供安全、舒适、便捷的工作与生活环境。%This article summarizes the new concept of Chinese super high-rise building design. Combined with the examples of Shanghai Tower, this paper elaborates the sustainable management experience in intelligent building management,energy management,security and service man-agement. It wants to provide safety,comfortable and convenient working and living environment for the future users.

  20. Super Tomboy Style

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Sparked by Super Girl, the androgynous look is in among Chinese youth On September 8, this year's top six contestants on the Super Girl television show, a singing contest for young women, stepped into the spotlight. Nearly none of them had long black hair or wore evening gowns, traditionally associated with beauty in China. Rather, they

  1. Highly sensitive and multiplexed platforms for allergy diagnostics

    Science.gov (United States)

    Monroe, Margo R.

    Allergy is a disorder of the immune system caused by an immune response to otherwise harmless environmental allergens. Currently 20% of the US population is allergic and 90% of pediatric patients and 60% of adult patients with asthma have allergies. These percentages have increased by 18.5% in the past decade, with predicted similar trends for the future. Here we design sensitive, multiplexed platforms to detect allergen-specific IgE using the Interferometric Reflectance Imaging Sensor (IRIS) for various clinical settings. A microarray platform for allergy diagnosis allows for testing of specific IgE sensitivity to a multitude of allergens, while requiring only small volumes of patient blood sample. However, conventional fluorescent microarray technology is limited by i) the variation of probe immobilization, which hinders the ability to make quantitative, assertive, and statistically relevant conclusions necessary in immunodiagnostics and ii) the use of fluorophore labels, which is not suitable for some clinical applications due to the tendency of fluorophores to stick to blood particulates and require daily calibration methods. This calibrated fluorescence enhancement (CaFE) method integrates the low magnification modality of IRIS with enhanced fluorescence sensing in order to directly correlate immobilized probe (major allergens) density to allergen-specific IgE in patient serum. However, this platform only operates in processed serum samples, which is not ideal for point of care testing. Thus, a high magnification modality of IRIS was adapted as an alternative allergy diagnostic platform to automatically discriminate and size single nanoparticles bound to specific IgE in unprocessed, characterized human blood and serum samples. These features make IRIS an ideal candidate for clinical and diagnostic applications, such a POC testing. The high magnification (nanoparticle counting) modality in conjunction with low magnification of IRIS in a combined instrument

  2. High Sensitive Precise 3D Accelerometer for Solar System Exploration with Unmanned Spacecrafts

    Science.gov (United States)

    Savenko, Y. V.; Demyanenko, P. O.; Zinkovskiy, Y. F.

    Solutions of several space and geophysical tasks require creating high sensitive precise accelerometers with sensitivity in order of 10 -13 g. These several tasks are following: inertial navigation of the Earth and Space; gravimetry nearby the Earth and into Space; geology; geophysics; seismology etc. Accelerometers (gravimeters and gradientmeters) with required sensitivity are not available now. The best accelerometers in the world have sensitivity worth on 4-5 orders. It has been developed a new class of fiber-optical sensors (FOS) with light pulse modulation. These sensors have super high threshold sensitivity and wide (up to 10 orders) dynamic range, and can be used as a base for creating of measurement units of physical values as 3D superhigh sensitive precise accelerometers of linear accelerations that is suitable for highest requirements. The principle of operation of the FOS is organically combined with a digital signal processing. It allows decreasing hardware of the accelerometer due to using a usual air-borne or space-borne computer; correcting the influence of natural, design, technological drawbacks of FOS on measured results; neutralising the influence of extraordinary situations available during using of FOS; decreasing the influence of internal and external destabilising factors (as for FOS), such as oscillation of environment temperature, instability of pendulum cycle frequency of sensitive element of the accelerometer etc. We were conducted a quantitative estimation of precise opportunities of analogue FOS in structure of fiber optical measuring devices (FOMD) for elementary FOMD with analogue FOS built on modern element basis of fiber optics (FO), at following assumptions: absolute parameter stability of devices of FOS measuring path; single transmission band of registration path; maximum possible inserted in optical fiber (OF) a radiated power. Even at such idealized assumptions, a calculated value in limit reached minimum inaccuracy of

  3. BEWARE OF...SUPER GLUES!!

    CERN Multimedia

    2006-01-01

    What happened? A number of accidents have occurred with the use of 'Super Glues'. Some individuals have suffered injuries - severe irritation, or skin bonded together - through getting glue on their face and in their eyes. What are the hazards associated with glues? 'Super Glues' (i.e. cyanoacrylates): Are harmful if swallowed and are chemical irritants to the eyes, respiratory system and skin. Present the risk of polymerization (hardening) leading to skin damage. Be careful ! 'Super Glues' can bond to skin and eyes in seconds. Note: Other glues, resins and hardeners are also chemicals and as such can cause serious damage to the skin, eyes, respiratory or digestive tract. (For example: some components can be toxic, harmful, corrosive, sensitizing agents, etc.). How to prevent accidents in the future? Read the Material Safety Data Sheet (MSDS) for all of the glues you work with. Check the label on the container to find out which of the materials you work with are hazardous. Wear the right Per...

  4. Characterization of Three High Efficiency and Blue Sensitive Silicon Photomultipliers

    CERN Document Server

    Otte, Adam Nepomuk; Nguyen, Thanh; Purushotham, Dhruv

    2016-01-01

    We report about the optical and electrical characterization of three high efficiency and blue sensitive Silicon photomultipliers from FBK, Hamamatsu, and SensL. Key features of the tested devices when operated at 90% breakdown probability are peak photon detection efficiencies between 40% and 55%, temperature dependencies of gain and PDE that are less than 1%/$^{\\circ}$C, dark rates of $\\sim$50\\,kHz/mm$^{2}$ at room temperature, afterpulsing of about 2%, and direct optical crosstalk between 6% and 20%. The characteristics of all three devices impressively demonstrate how the Silicon-photomultiplier technology has improved over the past ten years. It is further demonstrated how the voltage and temperature characteristics of a number of quantities can be parameterized on the basis of physical models. The models provide a deeper understanding of the device characteristics over a wide bias and temperature range. They also serve as examples how producers could provide the characteristics of their SiPMs to users. A...

  5. Characterization of three high efficiency and blue sensitive silicon photomultipliers

    Science.gov (United States)

    Otte, Adam Nepomuk; Garcia, Distefano; Nguyen, Thanh; Purushotham, Dhruv

    2017-02-01

    We report about the optical and electrical characterization of three high efficiency and blue sensitive Silicon photomultipliers from FBK, Hamamatsu, and SensL. Key features of the tested devices when operated at 90% breakdown probability are peak photon detection efficiencies between 40% and 55%, temperature dependencies of gain and PDE that are less than 1%/°C, dark rates of ∼50 kHz/mm2 at room temperature, afterpulsing of about 2%, and direct optical crosstalk between 6% and 20%. The characteristics of all three devices impressively demonstrate how the Silicon-photomultiplier technology has improved over the past ten years. It is further demonstrated how the voltage and temperature characteristics of a number of quantities can be parameterized on the basis of physical models. The models provide a deeper understanding of the device characteristics over a wide bias and temperature range. They also serve as examples how producers could provide the characteristics of their SiPMs to users. A standardized parameterization of SiPMs would enable users to find the optimal SiPM for their application and the operating point of SiPMs without having to perform measurements thus significantly reducing design and development cycles.

  6. High Speed Pressure Sensitive Paint for Dynamic Testing

    Science.gov (United States)

    Pena, Carolina; Chism, Kyle; Hubner, Paul

    2016-11-01

    Pressure sensitive paint (PSP) allows engineers to obtain accurate, high-spatial-resolution measurements of pressure fields over a structure. The pressure is directly related to the luminescence emitted by the paint due to oxygen quenching. Fast PSP has a higher surface area due to its porosity compared to conventional PSP, which enables faster diffusion and measurements to be acquired three orders of magnitude faster than with conventional PSP. A fast time response is needed when testing vibrating structures due to fluid-structure interaction. The goal of this summer project was to set-up, test and analyze the pressure field of an impinging air jet on a vibrating cantilever beam using Fast PSP. Software routines were developed for the processing of the emission images, videos of a static beam coated with Fast PSP were acquired with the air jet on and off, and the intensities of these two cases were ratioed and calibrated to pressure. Going forward, unsteady pressures on a vibrating beam will be measured and presented. Eventually, the long-term goal is to integrate luminescent pressure and strain measurement techniques, simultaneously using Fast PSP and a luminescent photoelastic coating on vibrating structures. Funding from NSF REU site Grant EEC 1358991 is greatly appreciated.

  7. Ultra-high sensitivity imaging of cancer using SERRS nanoparticles

    Science.gov (United States)

    Kircher, Moritz F.

    2016-05-01

    "Surface-enhanced Raman spectroscopy" (SERS) nanoparticles have gained much attention in recent years for in silico, in vitro and in vivo sensing applications. Our group has developed novel generations of biocompatible "surfaceenhanced resonance Raman spectroscopy" (SERRS) nanoparticles as novel molecular imaging agents. Via rigorous optimization of the different variables contributing to the Raman enhancement, we were able to design SERRS nanoparticles with so far unprecedented sensitivity of detection under in vivo imaging conditions (femto-attomolar range). This has resulted in our ability to visualize, with a single nanoparticle, many different cancer types (after intravenous injection) in mouse models. The cancer types we have tested so far include brain, breast, esophagus, stomach, pancreas, colon, sarcoma, and prostate cancer. All mouse models used are state-of-the-art and closely mimic the tumor biology in their human counterparts. In these animals, we were able to visualize not only the bulk tumors, but importantly also microscopic extensions and locoregional satellite metastases, thus delineating for the first time the true extent of tumor spread. Moreover, the particles enable the detection of premalignant lesions. Given their inert composition they are expected to have a high chance for clinical translation, where we envision them to have an impact in various scenarios ranging from early detection, image-guidance in open or minimally invasive surgical procedures, to noninvasive imaging in conjunction with spatially offset (SESORS) Raman detection devices.

  8. Fabrication of highly efficient flexible dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Chang, H., E-mail: f10381@ntut.edu.t [Department of Mechanical Engineering, National Taipei University of Technology, No.1 Sec.3, Chung Hsiao E. Rd., Taipei 10608, Taiwan (China); Chen, T.L. [Department of Industrial Design, National Taipei University of Technology, No.1 Sec.3, Chung Hsiao E. Rd., Taipei 10608, Taiwan (China); Huang, K.D. [Department of Vehicle Engineering, National Taipei University of Technology, No.1 Sec.3, Chung Hsiao E. Rd., Taipei 10608, Taiwan (China); Chien, S.H. [Institute of Chemistry, Academia Sinica, No. 128 Sec.2, Academia Rd., Nankang, Taipei 11529, Taiwan (China); Hung, K.C. [Department of Mechanical Engineering, National Taipei University of Technology, No.1 Sec.3, Chung Hsiao E. Rd., Taipei 10608, Taiwan (China)

    2010-08-15

    The paper studies the fabrication of a flexible dye-sensitized solar cell (DSSC). The photoelectrode substrates are flexible stainless steel sheet with thickness 0.07 mm and titanium (Ti) sheet with thickness 0.25 mm. For the photoelectrode fabrication process, eletrophoresis deposition (EPD) was employed for its merits of low-cost and fast fabrication. With an electric field of 40 V/cm, after undergoing EPD process twice, the TiO{sub 2} nanofilm thickness could be controlled to around 13 {mu}m thick. In addition, to achieve counter electrode, sputtering method was applied to deposit Pt on ITO-PET, resulting in thin films with four different thicknesses of 5, 8, 11 and 14 nm. The experimental results showed that the best colloid solution used in EPD process was a mixture of 100 ml isopropyl alcohol (IPA) and 0.4 g commercial TiO{sub 2} nanoparticles, Degussa P25. The best flatness for a 13 {mu}m thick film could be acquired under an electric field of 40 V/cm. Comparing the photoelectric conversion efficiency values of DSSC assembled by counter electrodes with different Pt thicknesses, the experimental results showed that the best Pt thickness was 11 nm, and the conversion efficiency could reach as high as 2.91%.

  9. ASIC for High Rate 3D Position Sensitive Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Vernon, E.; De Geronimo, G.; Ackley, K.; Fried, J.; He, Z.; Herman, C.; Zhang, F.

    2010-06-16

    We report on the development of an application specific integrated circuit (ASIC) for 3D position sensitive detectors (3D PSD). The ASIC is designed to operate with pixelated wide bandgap sensors like Cadmium-Zinc-Telluride (CZT), Mercuric Iodide (Hgl2) and Thallium Bromide (TIBr). It measures the amplitudes and timings associated with an ionizing event on 128 anodes, the anode grid, and the cathode. Each channel provides low-noise charge amplification, high-order shaping with peaking time adjustable from 250 ns to 12 {micro}s, gain adjustable to 20 mV/fC or 120 mV/fC (for a dynamic range of 3.2 MeV and 530 keV in CZT), amplitude discrimination with 5-bit trimming, and positive and negative peak and timing detections. The readout can be full or sparse, based on a flag and single- or multi-cycle token passing. All channels, triggered channels only, or triggered with neighbors can be read out thus increasing the rate capability of the system to more than 10 kcps. The ASIC dissipates 330 mW which corresponds to about 2.5 mW per channel.

  10. Adjoint sensitivity analysis of high frequency structures with Matlab

    CERN Document Server

    Bakr, Mohamed; Demir, Veysel

    2017-01-01

    This book covers the theory of adjoint sensitivity analysis and uses the popular FDTD (finite-difference time-domain) method to show how wideband sensitivities can be efficiently estimated for different types of materials and structures. It includes a variety of MATLAB® examples to help readers absorb the content more easily.

  11. Highly sensitive NIR PtSi/Si-nanostructure detectors

    Science.gov (United States)

    Li, Hua-gao; Guo, Pei; Yuan, An-bo; Long, Fei; Li, Rui-zhi; Li, Ping; Li, Yi

    2016-10-01

    We report a high external quantum efficiency (EQE) photodiode detector with PtSi/Si-nanostructures. Black silicon nanostructures were fabricated by metal-assist chemical etching (MCE), a 2 nm Pt layer was subsequently deposited on black silicon surface by DC magnetron sputtering system, and PtSi/Si-nanostructures were formed in vacuum annealing at 450 oC for 5 min. As the PtSi/Si-nanostructures presented a spiky shape, the absorption of incident light was remarkably enhanced for the repeat reflection and absorption. The breakdown voltage, dark current, threshold voltage and responsivity of the device were investigated to evaluate the performance of the PtSi/Si-nanostructures detector. The threshold voltage and dark currents of the PtSi/Si-nanostructure photodiode tends to be slightly higher than those of the standard diodes. The breakdown voltage remarkably was reduced because of existing avalanche breakdown in PtSi/Si-nanostructures. However, the photodiodes had high response at room temperature in near infrared region. At -5 V reverse bias voltage, the responsivity was 0.72 A/W in 1064 nm wavelength, and the EQE was 83.9%. By increasing the reverse bias voltage, the responsivity increased. At -60 V reverse bias voltage, the responsivity was 3.5 A/W, and the EQE was 407.5%, which means the quantum efficiency of PtSi/Si-nanostructure photodiodes was about 10 times higher than that of a standard diode. Future research includes how to apply this technology to enhance the NIR sensitivity of image sensors, such as Charge Coupled Devices (CCD).

  12. High throughput modular chambers for rapid evaluation of anesthetic sensitivity

    Directory of Open Access Journals (Sweden)

    Eckmann David M

    2006-11-01

    Full Text Available Abstract Background Anesthetic sensitivity is determined by the interaction of multiple genes. Hence, a dissection of genetic contributors would be aided by precise and high throughput behavioral screens. Traditionally, anesthetic phenotyping has addressed only induction of anesthesia, evaluated with dose-response curves, while ignoring potentially important data on emergence from anesthesia. Methods We designed and built a controlled environment apparatus to permit rapid phenotyping of twenty-four mice simultaneously. We used the loss of righting reflex to indicate anesthetic-induced unconsciousness. After fitting the data to a sigmoidal dose-response curve with variable slope, we calculated the MACLORR (EC50, the Hill coefficient, and the 95% confidence intervals bracketing these values. Upon termination of the anesthetic, Emergence timeRR was determined and expressed as the mean ± standard error for each inhaled anesthetic. Results In agreement with several previously published reports we find that the MACLORR of halothane, isoflurane, and sevoflurane in 8–12 week old C57BL/6J mice is 0.79% (95% confidence interval = 0.78 – 0.79%, 0.91% (95% confidence interval = 0.90 – 0.93%, and 1.96% (95% confidence interval = 1.94 – 1.97%, respectively. Hill coefficients for halothane, isoflurane, and sevoflurane are 24.7 (95% confidence interval = 19.8 – 29.7%, 19.2 (95% confidence interval = 14.0 – 24.3%, and 33.1 (95% confidence interval = 27.3 – 38.8%, respectively. After roughly 2.5 MACLORR • hr exposures, mice take 16.00 ± 1.07, 6.19 ± 0.32, and 2.15 ± 0.12 minutes to emerge from halothane, isoflurane, and sevoflurane, respectively. Conclusion This system enabled assessment of inhaled anesthetic responsiveness with a higher precision than that previously reported. It is broadly adaptable for delivering an inhaled therapeutic (or toxin to a population while monitoring its vital signs, motor reflexes, and providing precise control

  13. Supermassive Black Holes with High Accretion Rates in Active Galactic Nuclei. IV. Hβ Time Lags and Implications for Super-Eddington Accretion

    Science.gov (United States)

    Du, Pu; Hu, Chen; Lu, Kai-Xing; Huang, Ying-Ke; Cheng, Cheng; Qiu, Jie; Li, Yan-Rong; Zhang, Yang-Wei; Fan, Xu-Liang; Bai, Jin-Ming; Bian, Wei-Hao; Yuan, Ye-Fei; Kaspi, Shai; Ho, Luis C.; Netzer, Hagai; Wang, Jian-Min; SEAMBH Collaboration

    2015-06-01

    We have completed two years of photometric and spectroscopic monitoring of a large number of active galactic nuclei (AGNs) with very high accretion rates. In this paper, we report on the result of the second phase of the campaign, during 2013-2014, and the measurements of five new Hβ time lags out of eight monitored AGNs. All five objects were identified as super-Eddington accreting massive black holes (SEAMBHs). The highest measured accretion rates for the objects in this campaign are \\mathscr{\\dot{M}} {\\mkern 1mu} ≳ 200, where \\mathscr{\\dot{M}} {\\mkern 1mu} ={{\\dot{M}}\\bullet }/{{L}Edd}{{c}-2}, {{\\dot{M}}\\bullet } is the mass accretion rates, {{L}Edd} is the Eddington luminosity and c is the speed of light. We find that the Hβ time lags in SEAMBHs are significantly shorter than those measured in sub-Eddington AGNs, and the deviations increase with increasing accretion rates. Thus, the relationship between broad-line region size ({{R}_{Hβ }}) and optical luminosity at 5100 Å, {{R}_{Hβ }}-{{L}5100}, requires accretion rate as an additional parameter. We propose that much of the effect may be due to the strong anisotropy of the emitted slim-disk radiation. Scaling {{R}_{Hβ }} by the gravitational radius of the black hole (BH), we define a new radius-mass parameter (Y) and show that it saturates at a critical accretion rate of \\mathscr{\\dot{M}} {\\mkern 1mu} {{}c}=6˜ 30, indicating a transition from thin to slim accretion disk and a saturated luminosity of the slim disks. The parameter Y is a very useful probe for understanding the various types of accretion onto massive BHs. We briefly comment on implications to the general population of super-Eddington AGNs in the universe and applications to cosmology.

  14. Possible Outcomes of Coplanar High-eccentricity Migration: Hot Jupiters, Close-in Super-Earths, and Counter-orbiting Planets

    Science.gov (United States)

    Xue, Yuxin; Masuda, Kento; Suto, Yasushi

    2017-02-01

    We investigate the formation of close-in planets in near-coplanar eccentric hierarchical triple systems via the secular interaction between an inner planet and an outer perturber (Coplanar High-eccentricity Migration; CHEM). We generalize the previous work on the analytical condition for successful CHEM for point masses interacting only through gravity by taking into account the finite mass effect of the inner planet. We find that efficient CHEM requires that the systems should have m1 ≪ m0 and m1 ≪ m2. In addition to the gravity for point masses, we examine the importance of the short-range forces, and provide an analytical estimate of the migration timescale. We perform a series of numerical simulations in CHEM for systems consisting of a Sun-like central star, giant gas inner planet, and planetary outer perturber, including the short-range forces and stellar and planetary dissipative tides. We find that most of such systems end up with a tidal disruption; a small fraction of the systems produce prograde hot Jupiters (HJs), but no retrograde HJ. In addition, we extend CHEM to super-Earth mass range, and show that the formation of close-in super-Earths in prograde orbits is also possible. Finally, we carry out CHEM simulation for the observed hierarchical triple and counter-orbiting HJ systems. We find that CHEM can explain a part of the former systems, but it is generally very difficult to reproduce counter-orbiting HJ systems.

  15. High-sensitivity high-throughput chip based biosensor array for multiplexed detection of heavy metals

    Science.gov (United States)

    Yan, Hai; Tang, Naimei; Jairo, Grace A.; Chakravarty, Swapnajit; Blake, Diane A.; Chen, Ray T.

    2016-03-01

    Heavy metal ions released into the environment from industrial processes lead to various health hazards. We propose an on-chip label-free detection approach that allows high-sensitivity and high-throughput detection of heavy metals. The sensing device consists of 2-dimensional photonic crystal microcavities that are combined by multimode interferometer to form a sensor array. We experimentally demonstrate the detection of cadmium-chelate conjugate with concentration as low as 5 parts-per-billion (ppb).

  16. Nonlinear Super Integrable Couplings of Super Classical-Boussinesq Hierarchy

    Directory of Open Access Journals (Sweden)

    Xiuzhi Xing

    2014-01-01

    Full Text Available Nonlinear integrable couplings of super classical-Boussinesq hierarchy based upon an enlarged matrix Lie super algebra were constructed. Then, its super Hamiltonian structures were established by using super trace identity. As its reduction, nonlinear integrable couplings of the classical integrable hierarchy were obtained.

  17. High sensitivity fiber Bragg grating pressure difference sensor

    Institute of Scientific and Technical Information of China (English)

    Haiwei Fu(傅海威); Junmei Fu(傅君眉); Xueguang Qiao(乔学光)

    2004-01-01

    Based on the effect of fiber Bragg grating (FBG) pressure difference sensitivity enhancement by encapsulating the FBG with uniform strength beam and metal bellows, a FBG pressure difference sensor is proposed, and its mechanism is also discussed. The relationship between Bragg wavelength and the pressure difference is derived, and the expression of the pressure difference sensitivity coefficient is also given. It is indicated that there is good linear relation between the Bragg wavelength shift and the pressure difference of the sensor. The theoretical and experimental pressure difference sensitivity coefficients are 38.67 and 37.6 nm/MPa, which are 12890 and 12533 times of that of the bare FBG, respectively. The pressure difference sensitivity and dynamic range can be easily changed by changing the size, Young's modulus, and Poisson's ratio of the beam and the bellows.

  18. Design of a High Sensitivity GNSS receiver for Lunar missions

    Science.gov (United States)

    Musumeci, Luciano; Dovis, Fabio; Silva, João S.; da Silva, Pedro F.; Lopes, Hugo D.

    2016-06-01

    This paper presents the design of a satellite navigation receiver architecture tailored for future Lunar exploration missions, demonstrating the feasibility of using Global Navigation Satellite Systems signals integrated with an orbital filter to achieve such a scope. It analyzes the performance of a navigation solution based on pseudorange and pseudorange rate measurements, generated through the processing of very weak signals of the Global Positioning System (GPS) L1/L5 and Galileo E1/E5 frequency bands. In critical scenarios (e.g. during manoeuvres) acceleration and attitude measurements from additional sensors complementing the GNSS measurements are integrated with the GNSS measurement to match the positioning requirement. A review of environment characteristics (dynamics, geometry and signal power) for the different phases of a reference Lunar mission is provided, focusing on the stringent requirements of the Descent, Approach and Hazard Detection and Avoidance phase. The design of High Sensitivity acquisition and tracking schemes is supported by an extensive simulation test campaign using a software receiver implementation and navigation results are validated by means of an end-to-end software simulator. Acquisition and tracking of GPS and Galileo signals of the L1/E1 and L5/E5a bands was successfully demonstrated for Carrier-to-Noise density ratios as low as 5-8 dB-Hz. The proposed navigation architecture provides acceptable performances during the considered critical phases, granting position and velocity errors below 61.4 m and 3.2 m/s, respectively, for the 99.7% of the mission time.

  19. A high sensitive fiber-optic strain sensor with tunable temperature sensitivity for temperature-compensation measurement

    Science.gov (United States)

    Hu, Jie; Huang, Hui; Bai, Min; Zhan, Tingting; Yang, Zhibo; Yu, Yan; Qu, Bo

    2017-02-01

    A high sensitive fiber-optic strain sensor, which consists of a cantilever, a tandem rod and a fiber collimator, was proposed. The tandem rod, which transfer the applied strain to the cantilever, was used for tuning the temperature sensitivity from ‑0.15 to 0.19 dB/°C via changing the length ratio of the rods. Moreover, due to the small beam divergence of the collimator, high strain sensitivity can be realized via incident-angle sensitive detection-mechanism. A strain detection-range of 1.1 × 103 με (with a sensing length of 21.5 mm), a detection limit of 5.7 × 10‑3 με, and a maximum operating frequency of 1.18 KHz were demonstrated. This sensor is promising for compensating the thermal-expansion of various target objects.

  20. 超稠油高温调剖封窜技术%High Temperature Profile Control and Channel Blocking Sealing Technology for Super Heavy Oil Researviors

    Institute of Scientific and Technical Information of China (English)

    郝建玉

    2012-01-01

    The cyclic steam stimulation is a recovery method of super heavy oil in Liaohe oilfield. The porosity of Du84 block of Xinglongtai oilfield in super heavy oil reservoir is generally 25% to 30%, air permeability is generally higher than 1306 × 10-3 μm2. Because of its high porosity and high permeability, steam channeling easily occurs to cause that heat energy of the injected steam can not be fully utilized, which can reduce production effect of the steam injection well. Water cut in adjacent well after the steam channeling increases, temperature rises, which can affect the production or cause to shut in well. Steam channeling aggravates casing deformation or damage. The high temperature resistant plugging agent can effectively block high permeability layer, adjust the steam absorption difference between low permeability layer and high permeability layer, change the flow direction of injected steam, which can alleviate the steam channeling, eliminate interference among wells, expand the injected steam swept volume, improve cycle oil production.%蒸汽吞吐开采是辽河油田超稠油主要开采方式.曙光油田杜84块兴隆台超稠油油藏孔隙度一般为25%~30%,空气渗透率一般高于1306×10-3 μm2,具有高孔隙度,高渗透率的特点,极易发生汽窜,导致注入蒸汽热能不能充分利用,直接降低了注汽井生产效果,使油藏动用不均的矛盾加剧.邻井受窜后含水升高液量突升,温度升高,影响其生产效果或关井防喷.汽窜加剧油层套管变形或损坏.研制的耐高温堵剂有效封堵高渗透层,调整地层高低渗透层带间的吸汽差异,改变注入蒸汽的走向,达到缓解汽窜、消除井间干扰、扩大注入蒸汽波及体积、提高周期采油量的目的.

  1. SuperB Progress Report for Physics

    Energy Technology Data Exchange (ETDEWEB)

    O' Leary, B.; /Aachen, Tech. Hochsch.; Matias, J.; Ramon, M.; /Barcelona, IFAE; Pous, E.; /Barcelona U.; De Fazio, F.; Palano, A.; /INFN, Bari; Eigen, G.; /Bergen U.; Asgeirsson, D.; /British Columbia U.; Cheng, C.H.; Chivukula, A.; Echenard, B.; Hitlin, D.G.; Porter, F.; Rakitin, A.; /Caltech; Heinemeyer, S.; /Cantabria Inst. of Phys.; McElrath, B.; /CERN; Andreassen, R.; Meadows, B.; Sokoloff, M.; /Cincinnati U.; Blanke, M.; /Cornell U., Phys. Dept.; Lesiak, T.; /Cracow, INP /DESY /Zurich, ETH /INFN, Ferrara /Frascati /INFN, Genoa /Glasgow U. /Indiana U. /Mainz U., Inst. Phys. /Karlsruhe, Inst. Technol. /KEK, Tsukuba /LBL, Berkeley /UC, Berkeley /Lisbon, IST /Ljubljana U. /Madrid, Autonoma U. /Maryland U. /MIT /INFN, Milan /McGill U. /Munich, Tech. U. /Notre Dame U. /PNL, Richland /INFN, Padua /Paris U., VI-VII /Orsay, LAL /Orsay, LPT /INFN, Pavia /INFN, Perugia /INFN, Pisa /Queen Mary, U. of London /Regensburg U. /Republica U., Montevideo /Frascati /INFN, Rome /INFN, Rome /INFN, Rome /Rutherford /Sassari U. /Siegen U. /SLAC /Southern Methodist U. /Tel Aviv U. /Tohoku U. /INFN, Turin /INFN, Trieste /Uppsala U. /Valencia U., IFIC /Victoria U. /Wayne State U. /Wisconsin U., Madison

    2012-02-14

    SuperB is a high luminosity e{sup +}e{sup -} collider that will be able to indirectly probe new physics at energy scales far beyond the reach of any man made accelerator planned or in existence. Just as detailed understanding of the Standard Model of particle physics was developed from stringent constraints imposed by flavour changing processes between quarks, the detailed structure of any new physics is severely constrained by flavour processes. In order to elucidate this structure it is necessary to perform a number of complementary studies of a set of golden channels. With these measurements in hand, the pattern of deviations from the Standard Model behavior can be used as a test of the structure of new physics. If new physics is found at the LHC, then the many golden measurements from SuperB will help decode the subtle nature of the new physics. However if no new particles are found at the LHC, SuperB will be able to search for new physics at energy scales up to 10-100 TeV. In either scenario, flavour physics measurements that can be made at SuperB play a pivotal role in understanding the nature of physics beyond the Standard Model. Examples for using the interplay between measurements to discriminate New Physics models are discussed in this document. SuperB is a Super Flavour Factory, in addition to studying large samples of B{sub u,d,s}, D and {tau} decays, SuperB has a broad physics programme that includes spectroscopy both in terms of the Standard Model and exotica, and precision measurements of sin{sup 2} {theta}{sub W}. In addition to performing CP violation measurements at the {Upsilon}(4S) and {phi}(3770), SuperB will test CPT in these systems, and lepton universality in a number of different processes. The multitude of rare decay measurements possible at SuperB can be used to constrain scenarios of physics beyond the Standard Model. In terms of other precision tests of the Standard Model, this experiment will be able to perform precision over

  2. High spectral response heteroleptic ruthenium (II) complexes as sensitizers for dye sensitized solar cells

    Indian Academy of Sciences (India)

    M Chandrasekharam; Ch Srinivasarao; T Suresh; M Anil Reddy; M Raghavender; G Rajkumar; M Srinivasu; P Yella Reddy

    2011-01-01

    Heteroleptic ruthenium(II) bipyridyl complex, cis-Ru(II)(4,4'-bis(4-tert-butylstyryl)-2,2'-bipyridyl) (4,4'-dicarboxy-2,2'-bipyridyl) (NCS2) (H112) was synthesized and characterized by 1H-NMR, MASS, Spectrofluorometer and UV-Vis spectroscopes. The photo-voltaic performance of the sensitizer was evaluated in Dye Sensitized Solar Cell (DSSC) under irradiation of AM 1.5 G solar light and the photovoltaic characteristics were compared with those of reference cells of HRS1 and N719 fabricated under comparable conditions. Compared to N719, H112 sensitizer showed enhanced molar extinction coefficient and relatively better monochromatic incident photon-to-current conversion efficiency (IPCE) across the spectral range of 400 to 800 nm with solar energy-to-electrical conversion efficiency () of 2.43% [open circuit photovoltage (VOC) = 0.631V, short-circuit photocurrent density (JSC) = 8.96 mA/cm2, fill factor (ff) = 0.430], while values of 2.51% (VOC = 0.651V, JSC = 9.41 mA/cm2, ff = 0.410) and 2.74% (VOC = 0.705 V, JSC = 8.62 mA/cm2, ff = 0.455) were obtained for HRS1 and N719 sensitized solar cells respectively. The introduction of 4,4'-bis(4-tert-butylstyryl) moieties on one of the bipyridine moieties of N719 complex shows higher light absorption abilities, IPCE and JSC.

  3. NETL Super Computer

    Data.gov (United States)

    Federal Laboratory Consortium — The NETL Super Computer was designed for performing engineering calculations that apply to fossil energy research. It is one of the world’s larger supercomputers,...

  4. Development of High Temperature/High Sensitivity Novel Chemical Resistive Sensor

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chonglin; Nash, Patrick; Ma, Chunrui; Enriquez, Erik; Wang, Haibing; Xu, Xing; Bao, Shangyong; Collins, Gregory

    2013-08-13

    The research has been focused to design, fabricate, and develop high temperature/high sensitivity novel multifunctional chemical sensors for the selective detection of fossil energy gases used in power and fuel systems. By systematically studying the physical properties of the LnBaCo{sub 2}O{sub 5+d} (LBCO) [Ln=Pr or La] thin-films, a new concept chemical sensor based high temperature chemical resistant change has been developed for the application for the next generation highly efficient and near zero emission power generation technologies. We also discovered that the superfast chemical dynamic behavior and an ultrafast surface exchange kinetics in the highly epitaxial LBCO thin films. Furthermore, our research indicates that hydrogen can superfast diffuse in the ordered oxygen vacancy structures in the highly epitaxial LBCO thin films, which suggest that the LBCO thin film not only can be an excellent candidate for the fabrication of high temperature ultra sensitive chemical sensors and control systems for power and fuel monitoring systems, but also can be an excellent candidate for the low temperature solid oxide fuel cell anode and cathode materials.

  5. A high-sensitivity push-pull magnetometer

    Science.gov (United States)

    Breschi, E.; Grujić, Z. D.; Knowles, P.; Weis, A.

    2014-01-01

    We describe our approach to atomic magnetometry based on the push-pull optical pumping technique. Cesium vapor is pumped and probed by a resonant laser beam whose circular polarization is modulated synchronously with the spin evolution dynamics induced by a static magnetic field. The magnetometer is operated in a phase-locked loop, and it has an intrinsic sensitivity below 20fT/√Hz , using a room temperature paraffin-coated cell. We use the magnetometer to monitor magnetic field fluctuations with a sensitivity of 300fT/√Hz .

  6. A high-sensitivity push-pull magnetometer

    CERN Document Server

    Breschi, E; Knowles, P; Weis, A

    2013-01-01

    We describe our approach to atomic magnetometry based on the push-pull optical pumping technique. Cesium vapor is pumped and probed by a resonant laser beam whose circular polarization is modulated synchronously with the spin evolution dynamics induced by a static magnetic field. The magnetometer is operated in a phase-locked loop, and it has an intrinsic sensitivity below 20fT/\\sqrt(Hz) using a room temperature paraffin-coated cell. We use the magnetometer to monitor magnetic field fluctuations with a sensitivity of 300fT/\\sqrt(Hz).

  7. High Sensitivity SPECT for Small Animals and Plants

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, Gregory S. [UC Davis

    2015-02-28

    Imaging systems using single gamma-ray emitting radioisotopes typically implement collimators in order to form the images. However, a tradeoff in sensitivity is inherent in the use of collimators, and modern preclinical single-photon emission computed tomography (SPECT) systems detect a very small fraction of emitted gamma-rays (<0.3%). We have built a collimator-less system, which can reach sensitivity of 40% for 99mTc imaging, while still producing images of sufficient spatial resolution for certain applications in thin objects such as mice, small plants, and well plates used for in vitro experiments.

  8. 超高压气井站场控制系统研究%Research on Control System of Super-high Pressure Gas Well

    Institute of Scientific and Technical Information of China (English)

    周晓; 四名; 邹凯

    2016-01-01

    This paper introduces the design of a RTU control system for super-high pressure gas wel based on the control wave redundant structure,integrated application of auto-control and touch screen terminal technology,with the function of output regulation,parameter monitoring and intel igent alarming,simulating manual operation steps,shut down the wel through pro-grammed language.The practical application shows that the system has the advantages of high stability and high intel igence.%介绍了一种基于CONTROL WAVE冗余架构的超高压气井RTU控制系统设计,集成运用自动化控制技术和触摸屏终端技术于一体,实现超高压气井的产量调节、参数监控和智能报警功能,模拟人工现场操作步骤,通过程序化的语言实现远程关井作业。实践应用表明该系统具有稳定性高、智能化程度高的优点。

  9. Super-Kamiokande

    Science.gov (United States)

    Magro, Lluís Martí

    2016-06-01

    The Super-Kamiokande experiment performs a large variety of studies, many of them in the neutrino sector. The archetypes are atmospheric neutrino (recently awarded with the Nobel prize for Mr. T. Kajita) and the solar neutrinos analyses. In these proceedings we report our latest results and present updates to indirect dark matter searches, our solar neutrino analysis and discuss the future upgrade of Super-Kamiokande by loading gadolinium into our ultra-pure water.

  10. The Super Girl Effect

    Institute of Scientific and Technical Information of China (English)

    WANG PEI

    2006-01-01

    @@ In recent years, Changsha,the capital city of Hunan Province, has become famous across China for its innovative TV channel, in particular the cultural phenomenon of the Super Girl talent show. And as far as culture goes, Hunan TV is merely a reflection of a renaissance happening in the city. Animation, music halls, drama festivals and a famous book market are just some of the city's cultural sectors that are benefiting from the fame and notoriety of the Super Girl show.

  11. Measurement of radon concentration in super-Kamiokande's buffer gas

    Science.gov (United States)

    Nakano, Y.; Sekiya, H.; Tasaka, S.; Takeuchi, Y.; Wendell, R. A.; Matsubara, M.; Nakahata, M.

    2017-09-01

    To precisely measure radon concentrations in purified air supplied to the Super-Kamiokande detector as a buffer gas, we have developed a highly sensitive radon detector with an intrinsic background as low as 0.33 ± 0.07 mBq /m3 . In this article, we discuss the construction and calibration of this detector as well as results of its application to the measurement and monitoring of the buffer gas layer above Super-Kamiokande. In March 2013, the chilled activated charcoal system used to remove radon in the input buffer gas was upgraded. After this improvement, a dramatic reduction in the radon concentration of the supply gas down to 0.08 ± 0.07 mBq /m3 . Additionally, the Rn concentration of the in-situ buffer gas has been measured 28.8 ± 1.7 mBq /m3 using the new radon detector. Based on these measurements we have determined that the dominant source of Rn in the buffer gas arises from contamination from the Super-Kamiokande tank itself.

  12. High-speed high-sensitivity infrared spectroscopy using mid-infrared swept lasers (Conference Presentation)

    Science.gov (United States)

    Childs, David T. D.; Groom, Kristian M.; Hogg, Richard A.; Revin, Dmitry G.; Cockburn, John W.; Rehman, Ihtesham U.; Matcher, Stephen J.

    2016-03-01

    Infrared spectroscopy is a highly attractive read-out technology for compositional analysis of biomedical specimens because of its unique combination of high molecular sensitivity without the need for exogenous labels. Traditional techniques such as FTIR and Raman have suffered from comparatively low speed and sensitivity however recent innovations are challenging this situation. Direct mid-IR spectroscopy is being speeded up by innovations such as MEMS-based FTIR instruments with very high mirror speeds and supercontinuum sources producing very high sample irradiation levels. Here we explore another possible method - external cavity quantum cascade lasers (EC-QCL's) with high cavity tuning speeds (mid-IR swept lasers). Swept lasers have been heavily developed in the near-infrared where they are used for non-destructive low-coherence imaging (OCT). We adapt these concepts in two ways. Firstly by combining mid-IR quantum cascade gain chips with external cavity designs adapted from OCT we achieve spectral acquisition rates approaching 1 kHz and demonstrate potential to reach 100 kHz. Secondly we show that mid-IR swept lasers share a fundamental sensitivity advantage with near-IR OCT swept lasers. This makes them potentially able to achieve the same spectral SNR as an FTIR instrument in a time x N shorter (N being the number of spectral points) under otherwise matched conditions. This effect is demonstrated using measurements of a PDMS sample. The combination of potentially very high spectral acquisition rates, fundamental SNR advantage and the use of low-cost detector systems could make mid-IR swept lasers a powerful technology for high-throughput biomedical spectroscopy.

  13. Cavity Enhanced Optical Vernier Spectroscopy, Broad Band, High Resolution, High Sensitivity

    CERN Document Server

    Gohle, Christoph; Schliesser, Albert; Udem, Thomas; Hänsch, Theodor W

    2007-01-01

    A femtosecond frequency comb provides a vast number of equidistantly spaced narrow band laser modes that can be simultaneously tuned and frequency calibrated with 15 digits accuracy. Our Vernier spectrometer utilizes all of theses modes in a massively parallel manner to rapidly record both absorption and dispersion spectra with a sensitivity that is provided by a high finesse broad band optical resonator and a resolution that is only limited by the frequency comb line width while keeping the required setup simple.

  14. The formation of super-rings

    CERN Document Server

    Tenorio-Tagle, G

    1980-01-01

    The author has calculated the collision of a small neutral cloud (surface density approximately 10/sup 19/ cm/sup -2/) with a constant density galactic disk. Through the collision, a large amount of energy is deposited in a small volume of the galaxy, resulting in a supersonic expansion of very hot (10/sup 6/-10/sup 7/K) gas into the Galaxy and out of the galactic disk. The expansion generates a large cavity (a super-ring) with physical characteristics (diameter, velocity of expansion, etc.) in agreement with the observations, and a large volume of hot low-density gas with properties similar to those of the observed coronal gas. (31 refs).

  15. Nonlinear Super Integrable Couplings of Super Dirac Hierarchy and Its Super Hamiltonian Structures

    Institute of Scientific and Technical Information of China (English)

    尤福财

    2012-01-01

    We construct nonlinear super integrable couplings of the super integrable Dirac hierarchy based on an enlarged matrix Lie superalgebra. Then its super Hamiltonian structure is furnished by super trace identity. As its reduction, we gain the nonlinear integrable couplings of the classical integrable Dirac hierarchy.

  16. Integrated SiC Super Junction Transistor-Diode Devices for High-Power Motor Control ModulesOoperating at 500 C Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Monolithic Integrated SiC Super Junction Transistor-JBS diode (MIDSJT) devices are used to construct 500

  17. Pajarito Monitor: a high-sensitivity monitoring system for highly enriched uranium

    Energy Technology Data Exchange (ETDEWEB)

    Fehlau, P.E.; Coop, K.; Garcia, C. Jr.; Martinez, J.

    1984-01-01

    The Pajarito Monitor for Special Nuclear Material is a high-sensitivity gamma-ray monitoring system for detecting small quantities of highly enriched uranium transported by pedestrians or motor vehicles. The monitor consists of two components: a walk-through personnel monitor and a vehicle monitor. The personnel monitor has a plastic-scintillator detector portal, a microwave occupancy monitor, and a microprocessor control unit that measures the radiation intensity during background and monitoring periods to detect transient diversion signals. The vehicle monitor examines stationary motor vehicles while the vehicle's occupants pass through the personnel portal to exchange their badges. The vehicle monitor has four groups of large plastic scintillators that scan the vehicle from above and below. Its microprocessor control unit measures separate radiation intensities in each detector group. Vehicle occupancy is sensed by a highway traffic detection system. Each monitor's controller is responsible for detecting diversion as well as serving as a calibration and trouble-shooting aid. Diversion signals are detected by a sequential probability ratio hypothesis test that minimizes the monitoring time in the vehicle monitor and adapts itself well to variations in individual passage speed in the personnel monitor. Designed to be highly sensitive to diverted enriched uranium, the monitoring system also exhibits exceptional sensitivity for plutonium. 6 references, 9 figures, 2 tables.

  18. (E)-Propyl α-Cyano-4-Hydroxyl Cinnamylate: A High Sensitive and Salt Tolerant Matrix for Intact Protein Profiling by MALDI Mass Spectrometry

    Science.gov (United States)

    Wang, Sheng; Xiao, Zhaohui; Xiao, Chunsheng; Wang, Huixin; Wang, Bing; Li, Ying; Chen, Xuesi; Guo, Xinhua

    2016-04-01

    Low-abundance samples and salt interference are always of great challenges for the practical protein profiling by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Herein, a series of carboxyl-esterified derivatives of α-cyano-4-hydroxycinnamic acid (CHCA) were synthesized and evaluated as matrices for MALDI-MS analysis of protein. Among them, (E)-propyl α-cyano-4-hydroxyl cinnamylate (CHCA-C3) was found to exhibit excellent assay performance for intact proteins by improving the detection sensitivity 10 folds compared with the traditional matrices [i.e., super2,5-dihydroxybenzoic acid (superDHB), sinapic acid (SA), and CHCA]. In addition, CHCA-C3 was shown to have high tolerance to salts, the ion signal of myoglobin was readily detected even in the presence of urea (8 M), NH4HCO3 (2 M), and KH2PO4 (500 mM), meanwhile sample washability was robust. These achievements were mainly attributed to improved ablation ability and increased hydrophobicity or affinity of CHCA-C3 to proteins in comparison with hydrophilic matrixes, leading to more efficient ionization of analyte. Furthermore, direct analysis of proteins from crude egg white demonstrated that CHCA-C3 was a highly efficient matrix for the analysis of low-abundance proteins in complex biological samples. These outstanding performances indicate the tremendous potential use of CHCA-C3 in protein profiling by MALDI-MS.

  19. Quartz splintTM高强度石英纤维和Super-Bond C & B粘结剂固定下前牙松动牙疗效比较%Comparison of the clinical effect of Quartz splintTM high strength quartz fiber and Super-Bond C & B adhesive for anterior teeth loosening

    Institute of Scientific and Technical Information of China (English)

    赵静

    2016-01-01

    目的:比较Quartz splintTM高强度石英纤维和Super-Bond C&B粘结剂固定慢性牙周炎下前牙松动牙的临床效果。方法:选取下前牙松动需要做牙周夹板松牙固定患者40例,随机分为两组。A组:在洁治、刮治和根面平整后,使用Quartz splintTM高强度石英纤维做牙周固定;B组:在在洁治、刮治和根面平整后,使用Super-Bond C&B粘结剂做牙周固定。两组固定后即刻让患者对于固定物做出异物感评价。固定6个月后比较治疗前后的牙周探诊深度和牙周附着丧失情况。结果:两组治疗前后的牙周探诊深度和牙周附着丧失均比治疗前有明显减少,有统计学意义。组间比较,无统计学意义。固定后即刻异物感评价,B组优于A组,有统计学意义。结论:对于下前牙松动的患者,洁治、刮治和根面平整后使用Quartz splintTM高强度石英纤维和Super-Bond C&B粘结剂牙周夹板固定,均可以使牙周状况明显改善。Super-Bond C&B粘结剂牙周夹板异物感小于Quartz splintTM高强度石英纤维。%Objective To compare the clinical effect of Quartz splintTM high strength silica fiber and Super-Bond C&B adhesive in the treatment of anterior teeth loosening of the periodontal disease. Methods 40 patients with anterior teeth loosening need to be fixed in patients with loose teeth, and were randomly divided into two groups. In group A, scaling and root planing, the use of Quartz splintTM high strength quartz fiber periodontal fixed. In group B, scaling, root planing, the use of Super-Bond C&B adhesive periodontal fixation. A group and B group make foreign body sensation evaluation after fixation immediately. After 6 months of treatment, the depth of the periodontal probe and the loss of periodontal attachment were compared with that before and after the treatment. Results The depth of the periodontal probe and the loss of periodontal attachment in the A group and the B

  20. Operation of a 400MHz NMR magnet using a (RE:Rare Earth)Ba2Cu3O7-x high-temperature superconducting coil: Towards an ultra-compact super-high field NMR spectrometer operated beyond 1GHz.

    Science.gov (United States)

    Yanagisawa, Y; Piao, R; Iguchi, S; Nakagome, H; Takao, T; Kominato, K; Hamada, M; Matsumoto, S; Suematsu, H; Jin, X; Takahashi, M; Yamazaki, T; Maeda, H

    2014-10-18

    High-temperature superconductors (HTS) are the key technology to achieve super-high magnetic field nuclear magnetic resonance (NMR) spectrometers with an operating frequency far beyond 1GHz (23.5T). (RE)Ba2Cu3O7-x (REBCO, RE: rare earth) conductors have an advantage over Bi2Sr2Ca2Cu3O10-x (Bi-2223) and Bi2Sr2CaCu2O8-x (Bi-2212) conductors in that they have very high tensile strengths and tolerate strong electromagnetic hoop stress, thereby having the potential to act as an ultra-compact super-high field NMR magnet. As a first step, we developed the world's first NMR magnet comprising an inner REBCO coil and outer low-temperature superconducting (LTS) coils. The magnet was successfully charged without degradation and mainly operated at 400MHz (9.39T). Technical problems for the NMR magnet due to screening current in the REBCO coil were clarified and solved as follows: (i) A remarkable temporal drift of the central magnetic field was suppressed by a current sweep reversal method utilizing ∼10% of the peak current. (ii) A Z2 field error harmonic of the main coil cannot be compensated by an outer correction coil and therefore an additional ferromagnetic shim was used. (iii) Large tesseral harmonics emerged that could not be corrected by cryoshim coils. Due to those harmonics, the resolution and sensitivity of NMR spectra are ten-fold lower than those for a conventional LTS NMR magnet. As a result, a HSQC spectrum could be achieved for a protein sample, while a NOESY spectrum could not be obtained. An ultra-compact 1.2GHz NMR magnet could be realized if we effectively take advantage of REBCO conductors, although this will require further research to suppress the effect of the screening current.

  1. A Trio of Super-Earths

    Science.gov (United States)

    2008-06-01

    Earth, orbit the star with periods of 4.3, 9.6, and 20.4 days, respectively. RV signal ESO PR Photo 19b/08 Radial Velocity Variations "The perturbations induced by the planets are really tiny - the mass of the smallest planets is one hundred thousand times smaller than that of the star - and only the high sensitivity of HARPS made it possible to detect them," says co-author François Bouchy, from the Institut d'Astrophysique de Paris, France. Indeed, each planet induces a motion of the star of only a few metres per second. At the same conference, the team of astronomers announced the discovery of two other planetary systems, also with the HARPS spectrograph. In one, a super-Earth (7.5 Earth masses) orbits the star HD 181433 in 9.5 days. This star also hosts a Jupiter-like planet with a period close to 3 years. The second system contains a 22 Earth-mass planet having a period of 4 days and a Saturn-like planet with a 3-year period as well. "Clearly these planets are only the tip of the iceberg," says Mayor. "The analysis of all the stars studied with HARPS shows that about one third of all solar-like stars have either super-Earth or Neptune-like planets with orbital periods shorter than 50 days." A planet in a tight, short-period orbit is indeed easier to find than one in a wide, long-period orbit. "It is most probable that there are many other planets present: not only super-Earth and Neptune-like planets with longer periods, but also Earth-like planets that we cannot detect yet. Add to it the Jupiter-like planets already known, and you may well arrive at the conclusion that planets are ubiquitous," concludes Udry. More information These discoveries have been announced today at the international conference "Extra-solar Super-Earths" which takes place in Nantes, France, from 16 to 18 June. Two papers on these discoveries have also been submitted to the research journal Astronomy and Astrophysics. The team is composed of Michel Mayor, Stéphane Udry, Didier Queloz

  2. Desensitization protocol in highly HLA-sensitized and ABO-incompatible high titer kidney transplantation.

    Science.gov (United States)

    Uchida, J; Machida, Y; Iwai, T; Naganuma, T; Kitamoto, K; Iguchi, T; Maeda, S; Kamada, Y; Kuwabara, N; Kim, T; Nakatani, T

    2010-12-01

    A positive crossmatch indicates the presence of donor-specific alloantibodies and is associated with a graft loss rate of >80%; anti-ABO blood group antibodies develop in response to exposure to foreign blood groups, resulting in immediate graft loss. However, a desensitization protocol for highly HLA-sensitized and ABO-incompatible high-titer kidney transplantation has not yet been established. We treated 6 patients with high (≥1:512) anti-A/B antibody titers and 2 highly HLA-sensitized patients. Our immunosuppression protocol was initiated 1 month before surgery and included mycophenolate mofetil (1 g/d) and/or low-dose steroid (methylprednisolone 8 mg/d). Two doses of the anti-CD20 antibody rituximab (150 mg/m(2)) were administered 2 weeks before and on the day of transplantation. We performed antibody removal with 6-12 sessions of plasmapheresis (plasma exchange or double-filtration plasmapheresis) before transplantation. Splenectomy was also performed on the day of transplantation. Postoperative immunosuppression followed the same regimen as ABO-compatible cases, in which calcineurin inhibitors were initiated 3 days before transplantation, combined with 2 doses of basiliximab. Of the 8 patients, 7 subsequently underwent successful living-donor kidney transplantation. Follow-up of our recipients showed that the patient and graft survival rates were 100%. Acute cellular rejection and antibody-mediated rejection episodes occurred in 1 of the 7 recipients. These findings suggest that our immunosuppression regimen consisting of rituximab infusions, splenectomy, plasmapheresis, and pharmacologic immunosuppression may prove to be effective as a desensitization protocol for highly HLA-sensitized and ABO-incompatible high-titer kidney transplantation. Copyright © 2010 Elsevier Inc. All rights reserved.

  3. Temperature insensitive hysteresis free highly sensitive polymer optical fiber Bragg grating humidity sensor

    DEFF Research Database (Denmark)

    Woyessa, Getinet; Nielsen, Kristian; Stefani, Alessio

    2016-01-01

    sensitivity and a high hysteresis in the humidity response, in particular when operated at high temperature. PMMA mPOFBGs annealed at high humidity show higher and more linear humidity sensitivity with negligible hysteresis. We also report how annealing at high humidity can blue-shift the FBG wavelength more...

  4. Linear analysis on the onset of thermal convection of highly compressible fluids: implications for the mantle convection of super-Earths

    Science.gov (United States)

    Kameyama, Masanori; Miyagoshi, Takehiro; Ogawa, Masaki

    2015-02-01

    A series of linear analysis was performed on the onset of thermal convection of highly compressible fluids, in order to deepen the fundamental insights into the mantle convection of massive super-Earths in the presence of strong adiabatic compression. We consider the temporal evolution (growth or decay) of an infinitesimal perturbation superimposed to a highly compressible fluid which is in a hydrostatic (motionless) and conductive state in a basally heated horizontal layer. As a model of pressure-dependence in material properties, we employed an exponential decrease in thermal expansivity α and exponential increase in (reference) density ρ with depth. The linearized equations for conservation of mass, momentum and internal (thermal) energy are numerically solved for the critical Rayleigh number as well as the vertical profiles of eigenfunctions for infinitesimal perturbations. The above calculations are repeatedly carried out by systematically varying (i) the dissipation number (Di), (ii) the temperature at the top surface and (iii) the magnitude of pressure-dependence in α and ρ. Our analysis demonstrated that the onset of thermal convection is strongly affected by the adiabatic compression, in response to the changes in the static stability of thermal stratification in the fluid layer. For sufficiently large Di where a thick sublayer of stable stratification develops in the layer, for example, the critical Rayleigh number explosively increases with Di, together with drastic decreases in the length scales of perturbations both in vertical and horizontal directions. In particular, for very large Di, a thick `stratosphere' occurs in the fluid layer where the vertical motion is significantly suppressed, resulting in a shrink of the incipient convection in a thin sublayer of unstable thermal stratification. In addition, when Di exceeds a threshold value above which a thermal stratification becomes stable in the entire layer, no perturbation is allowed to grow

  5. 超高层建筑群绿色施工综合应用技术%Comprehensive Technology Applied in Green Construction on Super High Rise Buildings

    Institute of Scientific and Technical Information of China (English)

    周睿; 禹航; 赵淑容

    2014-01-01

    The Western International Financial Center project paid high attention to green construction. Resources like water,land,energy,materials and pollution have been effectively controlled,especially the three applied innovative technologies about waste treatment,mobile toilet,concrete pump cleaning were carried out on super high rise buildings,which achieved greater level on green construction.%西部国际金融中心项目高度重视绿色施工,对水资源、土地资源、能源、材料和环境污染等进行有效控制,尤其项目实施的超高层垃圾管道、临时厕所、混凝土洗泵管3项创新改良后的施工技术,使项目绿色施工达到更为良好的效果。

  6. Spectral responsivity calibration of the reference radiation thermometer at KRISS by using a super-continuum laser-based high-accuracy monochromatic source

    Science.gov (United States)

    Yoo, Yong Shim; Kim, Gun Jung; Park, Seongchong; Lee, Dong-Hoon; Kim, Bong-Hak

    2016-12-01

    We report on the calibration of the relative spectral responsivity of the reference radiation thermometer, model LP4, which is used for the experimental realisation of the international temperature scale of 1990 above 960 °C at the Korea Research Institute of Standards and Science. The relative spectral responsivity of LP4 is measured by using a monochromatic source consisting of a super-continuum laser and a double-grating monochromator. By monitoring the wavelength of the output beam directly with a calibrated wavelength-meter, we achieved a high-accuracy measurement of spectral responsivity with a maximum wavelength error of less than 3 pm, a narrow spectral bandwidth of less than 0.4 nm, and a high dynamic range over 8 decades. We evaluated the contributions of various uncertainty components of the spectral responsivity measurement to the uncertainty of the temperature scale based on a practical estimation approach, which numerically calculates the maximal effects of the variations of each component. As a result, we evaluate the uncertainty contribution from the spectral responsivity measurement to the temperature scale to be less than 64 mK (k  =  1) in a range from 660 °C to 2749 °C for the LP4 with a filter at 650 nm.

  7. Feedback in the Antennae Galaxies (NGC 4038/9): I. High-Resolution Infrared Spectroscopy of Winds from Super Star Clusters

    Energy Technology Data Exchange (ETDEWEB)

    Gilbert, A; Graham, J

    2007-06-05

    We present high-resolution (R {approx} 24,600) near-IR spectroscopy of the youngest super star clusters (SSCs) in the prototypical starburst merger, the Antennae Galaxies. These SSCs are young (3-7 Myr old) and massive (10{sup 5}-10{sup 7} M{sub {circle_dot}} for a Kroupa IMF) and their spectra are characterized by broad, extended Brackett {gamma} emission, so we refer to them as emission-line clusters (ELCs) to distinguish them from older SSCs. The Br {gamma} lines of most ELCs have supersonic widths (60-110 km s{sup -1} FWHM) and non-Gaussian wings whose velocities exceed the clusters escape velocities. This high-velocity unbound gas is flowing out in winds that are powered by the clusters massive O and W-R stars over the course of at least several crossing times. The large sizes of some ELCs relative to those of older SSCs may be due to expansion caused by these outflows; many of the ELCs may not survive as bound stellar systems, but rather dissipate rapidly into the field population. The observed tendency of older ELCs to be more compact than young ones is consistent with the preferential survival of the most concentrated clusters at a given age.

  8. A super-high angular resolution principle for coded-mask X-ray imaging beyond the diffraction limit of a single pinhole

    Institute of Scientific and Technical Information of China (English)

    Chen Zhang; Shuang-Nan Zhang

    2009-01-01

    High angular resolution X-ray imaging is always useful in astrophysics and solar physics. In principle, it can be performed by using coded-mask imaging with a very long mask-detector distance. Previously, the diffraction-interference effect was thought to degrade coded-mask imaging performance dramatically at the low energy end with its very long mask-detector distance. The diffraction-interference effect is described with numerical calculations, and the difffraction-interference cross correlation reconstruction method (DICC) is developed in order to overcome the imaging performance degradation. Based on the DICC, a super-high angular resolution principle (SHARP) for coded-mask X-ray imaging is proposed. The feasibility of coded mask imaging beyond the diffraction limit of a single pinhole is demonstrated with simulations. With the specification that the mask element size is 50 × 50 μm2 and the mask-detector distance is 50 m, the achieved angular resolution is 0.32arcsec above about 10keV and 0.36arcsec at 1.24keV (λ = 1 nm), where diffraction cannot be neglected. The on-axis source location accuracy is better than 0.02 arcsec. Potential applications for solar observations and wide-field X-ray monitors are also briefly discussed.

  9. A Super-high Angular Resolution Principle for Coded-mask X-ray Imaging Beyond the Diffraction Limit of Single Pinhole

    CERN Document Server

    Zhang, Chen

    2008-01-01

    High angular resolution X-ray imaging is always demanded by astrophysics and solar physics, which can be realized by coded-mask imaging with very long mask-detector distance in principle. Previously the diffraction-interference effect has been thought to degrade coded-mask imaging performance dramatically at low energy end with very long mask-detector distance. In this work the diffraction-interference effect is described with numerical calculations, and the diffraction-interference cross correlation reconstruction method (DICC) is developed in order to overcome the imaging performance degradation. Based on the DICC, a super-high angular resolution principle (SHARP) for coded-mask X-ray imaging is proposed. The feasibility of coded mask imaging beyond the diffraction limit of single pinhole is demonstrated with simulations. With the specification that the mask element size of 50* 50 square micrometers and the mask-detector distance of 50 m, the achieved angular resolution is 0.32 arcsec above about 10 keV, an...

  10. Properties of High Redshift Quasars-II: What does the quasar luminosity function tell us about super-massive black-hole evolution?

    CERN Document Server

    Wyithe, S; Wyithe, Stuart

    2006-01-01

    In the local universe, the masses of Super-Massive Black-Holes (SMBH) appear to correlate with the physical properties of their hosts, including the mass of the dark-matter halo. Using these clues as a starting point many studies have produced models that can explain phenomena like the quasar luminosity function. The shortcoming of this approach is that working models are not unique, and as a result it is not always clear what input physics is being constrained. Here we take a different approach. We identify critical parameters that describe the evolution of SMBHs at high redshift, and constrain their parameter space based on observations of high redshift quasars from the Sloan Digital Sky Survey. We find that the luminosity function taken in isolation is somewhat limited in its ability to constrain SMBH evolution due to some strong degeneracies. This explains the presence in the literature of a range of equally successful models based on different physical hypotheses. Including the constraint of the local SM...

  11. Avaliação da eficácia clínica de uma nova modalidade de fototerapia utilizando diodos emissores de luz Efficacy of new microprocessed phototherapy system with five high intensity light emitting diodes (Super LED

    Directory of Open Access Journals (Sweden)

    Bianca M. R. Martins

    2007-06-01

    Full Text Available OBJETIVO: Avaliar a eficácia terapêutica de um sistema de fototerapia microprocessada que utiliza diodos emissores de luz (Super LED de alta intensidade no tratamento da hiperbilirrubinemia em recém-nascidos prematuros. MÉTODOS: Ensaio clínico, randomizado e controlado, utilizando a fototerapia Super LED no grupo experimental e duas fototerapias halógenas no grupo controle. A randomização foi realizada em blocos e estratificada por peso de nascimento. A duração da fototerapia e a queda nos níveis séricos de bilirrubina total nas primeiras 24 horas de tratamento foram os principais desfechos analisados. RESULTADOS: Foram estudados 88 recém-nascidos, 44 no grupo da fototerapia Super LED e 44 no grupo da fototerapia halógena. As características demográficas da população foram semelhantes nos dois grupos. O nível sérico médio inicial de bilirrubina no grupo do Super LED (10,1±2,4 mg% foi semelhante ao do grupo que recebeu fototerapia halógena (10,9±2,0 mg%. A queda percentual na concentração sérica de bilirrubina total nas primeiras 24 horas de tratamento foi significativamente maior (27,9 versus 10,7%, p OBJECTIVES: To evaluate the efficacy of a microprocessed phototherapy (PT system with five high intensity light emitting diodes (Super LED for the treatment of neonatal hyperbilirubinemia of premature infants. METHODS: Randomized clinical trial using Super LED phototherapy in the study group and twin halogen spotlight phototherapy in the control group. A stratified blocked randomization, based on birth weight, was performed. The duration of phototherapy and the rate of decrease of total serum bilirubin (TSB concentration in the first 24 hours of treatment were the main outcome measures. RESULTS: We studied 88 infants, 44 in the Super LED group and 44 in the halogen spotlight PT group. The demographic characteristics of the patients in both groups were similar. Infants in the Super LED group had a similar mean initial

  12. Highly sensitive BTX detection using surface functionalized QCM sensor

    Energy Technology Data Exchange (ETDEWEB)

    Bozkurt, Asuman Aşıkoğlu; Özdemir, Okan; Altındal, Ahmet, E-mail: altindal@yildiz.edu.tr [Department of Physics, Yildiz Technical University, Davutpasa, 34210 Istanbul (Turkey)

    2016-03-25

    A novel organic compound was designed and successfully synthesized for the fabrication of QCM based sensors to detect the low concentrations of BTX gases in indoor air. The effect of the long-range electron orbital delocalization on the BTX vapour sensing properties of azo-bridged Pcs based chemiresistor-type sensors have also been investigated in this work. The sensing behaviour of the film for the online detection of volatile organic solvent vapors was investigated by utilizing an AT-cut quartz crystal resonator. It was observed that the adsorption of the target molecules on the coating surface cause a reversible negative frequency shift of the resonator. Thus, a variety of solvent vapors can be detected by using the phthalocyanine film as sensitive coating, with sensitivity in the ppm range and response times in the order of several seconds depending on the molecular structure of the organic solvent.

  13. Highly Sensitive Cadmium Concentration Sensor Using Long Period Grating

    Directory of Open Access Journals (Sweden)

    A. S. Lalasangi

    2011-08-01

    Full Text Available In this paper we have proposed a simple and effective Long Period Grating chemical sensor for detecting the traces of Cadmium (Cd++ in drinking water at ppm level. Long Period gratings (LPG were fabricated by point-by-point technique with CO2 laser. We have characterized the LPG concentration sensor sensitivity for different solutions of Cd concentrations varying from 0.01 ppm to 0.04 ppm by injecting white Light source and observed transmitted spectra using Optical Spectrum Analyzer (OSA. Proper reagents have been used in the solutions for detection of the Cd species. The overall shift in wavelength is 10 nm when surrounding medium gradually changed from water to 0.04 ppm of cadmium concentrations. A comparative study has been done using sophisticated spectroscopic atomic absorption spectrometer (AAS and Inductively Coupled Plasma (ICP instruments. The spectral sensitivity enhancement was done by modifying grating surface with gold nanoparticles.

  14. Highly sensitive detection using Herriott cell for laser absorption spectroscopy

    Science.gov (United States)

    Zhao, Chongyi; Song, Guangming; Du, Yang; Zhao, Xiaojun; Wang, Wenju; Zhong, Liujun; Hu, Mai

    2016-11-01

    The tunable diode laser absorption spectroscopy combined with the long absorption path technique is a significant method to detect harmful gas. The long optical path could come true by Herriott cell reducing the size of the spectrometers. A 15 cm long Herriott cell with 28.8 m optical absorption path after 96 times reflection was designed that enhanced detection sensitivity of absorption spectroscopy. According to the theory data of calculation, Herriott cell is analyzed and simulated by softwares Matlab and Lighttools.

  15. HIGH SENSITIVE C-REACTIVE PROTEIN IN CEREBROVASCULAR ISCHEMIA

    OpenAIRE

    Padmalatha; Neeraja

    2016-01-01

    BACKGROUND Cerebrovascular ischemia is recognized as a major health problem, which causes significant morbidity and mortality. The main pathophysiology of ischemic stroke is atherosclerosis of cerebral vessels. Hs-CRP is a sensitive marker of inflammation tissue injury in the arterial wall, which contributes to atherosclerosis. In this study, we aim to investigate the association of hs-CRP in patients with ischemic stroke and to correlate hs-CRP levels with possible risk facto...

  16. The strain-rate sensitivity of high-strength high-toughness steels.

    Energy Technology Data Exchange (ETDEWEB)

    Dilmore, M.F. (AFRL/MNMW, Eglin AFB, FL); Crenshaw, Thomas B.; Boyce, Brad Lee

    2006-01-01

    The present study examines the strain-rate sensitivity of four high strength, high-toughness alloys at strain rates ranging from 0.0002 s-1 to 200 s-1: Aermet 100, a modified 4340, modified HP9-4-20, and a recently developed Eglin AFB steel alloy, ES-1c. A refined dynamic servohydraulic method was used to perform tensile tests over this entire range. Each of these alloys exhibit only modest strain-rate sensitivity. Specifically, the strain-rate sensitivity exponent m, is found to be in the range of 0.004-0.007 depending on the alloy. This corresponds to a {approx}10% increase in the yield strength over the 7-orders of magnitude change in strain-rate. Interestingly, while three of the alloys showed a concominant {approx}3-10% drop in their ductility with increasing strain-rate, the ES1-c alloy actually exhibited a 25% increase in ductility with increasing strain-rate. Fractography suggests the possibility that at higher strain-rates ES-1c evolves towards a more ductile dimple fracture mode associated with microvoid coalescence.

  17. Antibody desensitization therapy in highly sensitized lung transplant candidates.

    Science.gov (United States)

    Snyder, L D; Gray, A L; Reynolds, J M; Arepally, G M; Bedoya, A; Hartwig, M G; Davis, R D; Lopes, K E; Wegner, W E; Chen, D F; Palmer, S M

    2014-04-01

    As HLAs antibody detection technology has evolved, there is now detailed HLA antibody information available on prospective transplant recipients. Determining single antigen antibody specificity allows for a calculated panel reactive antibodies (cPRA) value, providing an estimate of the effective donor pool. For broadly sensitized lung transplant candidates (cPRA ≥ 80%), our center adopted a pretransplant multi-modal desensitization protocol in an effort to decrease the cPRA and expand the donor pool. This desensitization protocol included plasmapheresis, solumedrol, bortezomib and rituximab given in combination over 19 days followed by intravenous immunoglobulin. Eight of 18 candidates completed therapy with the primary reasons for early discontinuation being transplant (by avoiding unacceptable antigens) or thrombocytopenia. In a mixed-model analysis, there were no significant changes in PRA or cPRA changes over time with the protocol. A sub-analysis of the median fluorescence intensity (MFI) change indicated a small decline that was significant in antibodies with MFI 5000-10,000. Nine of 18 candidates subsequently had a transplant. Posttransplant survival in these nine recipients was comparable to other pretransplant-sensitized recipients who did not receive therapy. In summary, an aggressive multi-modal desensitization protocol does not significantly reduce pretransplant HLA antibodies in a broadly sensitized lung transplant candidate cohort. © Copyright 2014 The American Society of Transplantation and the American Society of Transplant Surgeons.

  18. Deforming super Riemann surfaces with gravitinos and super Schottky groups

    Energy Technology Data Exchange (ETDEWEB)

    Playle, Sam [Dipartimento di Fisica, Università di Torino and INFN, Sezione di Torino,Via P. Giuria 1, I-10125 Torino (Italy)

    2016-12-12

    The (super) Schottky uniformization of compact (super) Riemann surfaces is briefly reviewed. Deformations of super Riemann surface by gravitinos and Beltrami parameters are recast in terms of super Schottky group cohomology. It is checked that the super Schottky group formula for the period matrix of a non-split surface matches its expression in terms of a gravitino and Beltrami parameter on a split surface. The relationship between (super) Schottky groups and the construction of surfaces by gluing pairs of punctures is discussed in an appendix.

  19. Super-Eccentric Migrating Jupiters

    CERN Document Server

    Socrates, Aristotle; Dong, Subo; Tremaine, Scott

    2011-01-01

    An important class of formation theories for hot Jupiters involves the excitation of extreme orbital eccentricity (e=0.99 or even larger) followed by tidal dissipation at periastron passage that eventually circularizes the planetary orbit at a period less than 10 days. In a steady state, this mechanism requires the existence of a significant population of super-eccentric (e>0.9) migrating Jupiters with long orbital periods and periastron distances of only a few stellar radii. For these super-eccentric planets, the periastron is fixed due to conservation of orbital angular momentum and the energy dissipated per orbit is constant, implying that the rate of change in semi-major axis a is \\dot a \\propto a^0.5 and consequently the number distribution satisfies dN/dlog a\\propto a^0.5. If this formation process produces most hot Jupiters, Kepler should detect several super-eccentric migrating progenitors of hot Jupiters, allowing for a test of high-eccentricity migration scenarios.

  20. SUPER-ECCENTRIC MIGRATING JUPITERS

    Energy Technology Data Exchange (ETDEWEB)

    Socrates, Aristotle; Katz, Boaz; Dong Subo; Tremaine, Scott [Institute for Advanced Study, Princeton, NJ 08540 (United States)

    2012-05-10

    An important class of formation theories for hot Jupiters involves the excitation of extreme orbital eccentricity (e = 0.99 or even larger) followed by tidal dissipation at periastron passage that eventually circularizes the planetary orbit at a period less than 10 days. In a steady state, this mechanism requires the existence of a significant population of super-eccentric (e > 0.9) migrating Jupiters with long orbital periods and periastron distances of only a few stellar radii. For these super-eccentric planets, the periastron is fixed due to conservation of orbital angular momentum and the energy dissipated per orbit is constant, implying that the rate of change in semi-major axis a is a-dot {proportional_to}a{sup 1/2} and consequently the number distribution satisfies dN/d log a{proportional_to}a{sup 1/2}. If this formation process produces most hot Jupiters, Kepler should detect several super-eccentric migrating progenitors of hot Jupiters, allowing for a test of high-eccentricity migration scenarios.

  1. High-performance and high-sensitivity applications of graphene transistors with self-assembled monolayers.

    Science.gov (United States)

    Yeh, Chao-Hui; Kumar, Vinod; Moyano, David Ricardo; Wen, Shao-Hsuan; Parashar, Vyom; Hsiao, She-Hsin; Srivastava, Anchal; Saxena, Preeti S; Huang, Kun-Ping; Chang, Chien-Chung; Chiu, Po-Wen

    2016-03-15

    Charge impurities and polar molecules on the surface of dielectric substrates has long been a critical obstacle to using graphene for its niche applications that involve graphene's high mobility and high sensitivity nature. Self-assembled monolayers (SAMs) have been found to effectively reduce the impact of long-range scatterings induced by the external charges. Yet, demonstrations of scalable device applications using the SAMs technique remains missing due to the difficulties in the device fabrication arising from the strong surface tension of the modified dielectric environment. Here, we use patterned SAM arrays to build graphene electronic devices with transport channels confined on the modified areas. For high-mobility applications, both rigid and flexible radio-frequency graphene field-effect transistors (G-FETs) were demonstrated, with extrinsic cutoff frequency and maximum oscillation frequency enhanced by a factor of ~2 on SiO2/Si substrates. For high sensitivity applications, G-FETs were functionalized by monoclonal antibodies specific to cancer biomarker chondroitin sulfate proteoglycan 4, enabling its detection at a concentration of 0.01 fM, five orders of magnitude lower than that detectable by a conventional colorimetric assay. These devices can be very useful in the early diagnosis and monitoring of a malignant disease.

  2. A novel lab-on-chip platform with integrated solid phase PCR and Supercritical Angle Fluorescence (SAF) microlens array for highly sensitive and multiplexed pathogen detection.

    Science.gov (United States)

    Hung, Tran Quang; Chin, Wai Hoe; Sun, Yi; Wolff, Anders; Bang, Dang Duong

    2017-04-15

    Solid-phase PCR (SP-PCR) has become increasingly popular for molecular diagnosis and there have been a few attempts to incorporate SP-PCR into lab-on-a-chip (LOC) devices. However, their applicability for on-line diagnosis is hindered by the lack of sensitive and portable on-chip optical detection technology. In this paper, we addressed this challenge by combining the SP-PCR with super critical angle fluorescence (SAF) microlens array embedded in a microchip. We fabricated miniaturized SAF microlens array as part of a microfluidic chamber in thermoplastic material and performed multiplexed SP-PCR directly on top of the SAF microlens array. Attribute to the high fluorescence collection efficiency of the SAF microlens array, the SP-PCR assay on the LOC platform demonstrated a high sensitivity of 1.6 copies/µL, comparable to off-chip detection using conventional laser scanner. The combination of SP-PCR and SAF microlens array allows for on-chip highly sensitive and multiplexed pathogen detection with low-cost and compact optical components. The LOC platform would be widely used as a high-throughput biosensor to analyze food, clinical and environmental samples.

  3. Highly sensitive method for diagnosis of subclinical B. ovis infection.

    Science.gov (United States)

    Horta, Sara; Barreto, Maria C; Pepe, Ana; Campos, Joana; Oliva, Abel

    2014-10-01

    Babesia ovis is a tick-transmitted protozoa parasite that infects small ruminants causing fever, anaemia, hemoglobinuria, anorexia and, in acute cases, death. Common in tropical and sub-tropical areas, the presence of this parasite in sheep herds has an economic impact on industry and therefore sensitive methods for the diagnosis and disease eradication are required. To achieve this goal, a semi-nested PCR for B. ovis specific identification was developed and consequent reaction conditions and enzymes were optimized and tested with field samples. 300 blood samples from small ruminants and 39 ticks from Rhipicephalus genus were collected from different regions of Portugal. Afterwards, DNA extraction was performed and conventional and semi-nested PCR were accomplished for all samples. The results obtained from both methodologies were compared and the sensitivity was evaluated. Employing the semi-nested PCR it was possible to identify a higher number of positive cases among the evaluated samples than using the conventional PCR, namely 38/300 blood samples and 7/39 ticks. However, fragment amplification was only observed in 5 out of 300 blood samples and in none of the 39 ticks when a conventional PCR was employed. The validation of the results was achieved by sequencing the DNA fragments corresponding to the hypervariable v4 region of the 18S ribosomal RNA gene and performing an alignment with sequences already published on GenBank(®). The ticks collected in this study belong to the Rhipicephalus genus, although other species could be involved as a vector in the Babesia spread. The diagnostic assay here described is presently the most effective and sensitive method for detection of B. ovis in field blood samples and ticks, enabling the detection up to 1 parasite into 10(9) erythrocytes. Copyright © 2014 Elsevier GmbH. All rights reserved.

  4. A New Resource-Saving, High Chromium and Manganese Super Duplex Stainless Steels 29Cr-12Mn-2Ni-1Mo-xN

    Institute of Scientific and Technical Information of China (English)

    MA Zheng-huan; ZHAO Xiang-juan; GE Chang-sheng; DING Tie-suo; LI Jun; XIAO Xue-shan

    2011-01-01

    A new family of resource saving, high chromium and manganese super duplex stainless steels (DSSs), with a composition in mass percent, % of Cr 0.29, Mn 0.12, Ni 2.0, Mo i. 0, and N 0. 51-0. 68, has been developed by examining the effect of N on the microstructure, mechanical properties and corrosion properties. The results show that these alloys have a balanced ferrite-austenite relation. The austenite volume fraction decreases with the solution treatment temperature, but it increases with an increase in N content. The increases in nitrogen enhance the ultimate tensile strength (UTS) and reduce the ductility of the material slightly. The pitting corrosion potential increases first and then decreases with an increase in nitrogen content when the amount of N arrives to 0.68%. The yield stress and ultimate tensile strength of solution treated samples were more than 680 and 900 MPa, the elongation of experimental alloys are higher than 30%, respectively, what is more, the pitting potentials were beyond 1 100 mV.

  5. A design of novel type superconducting magnet for super-high field functional magnetic resonance imaging by using the harmonic analysis method of magnetic vector potentials

    Institute of Scientific and Technical Information of China (English)

    俎栋林; 郭华; 宋枭禹; 包尚联

    2002-01-01

    The approach of expanding the magnetic scalar potential in a series of Legendre polynomials is suitable for designing a conventional superconducting magnetic resonance imaging magnet of distributed solenoidal configuration. Whereas the approach of expanding the magnetic vector potential in associated Legendre harmonics is suitable for designing a single-solenoid magnet that has multiple tiers, in which each tier may have multiple layers with different winding lengths. A set of three equations to suppress some of the lowest higher-order harmonics is found. As an example, a 4T single-solenoid magnetic resonance imaging magnet with 4 × 6 layers of superconducting wires is de signed The degree of homogeneity in the 0.5m diameter sphere volume is better than 5.8 ppm. The same degree of homogeneity is retained after optimal integralization of turns in each correction layer. The ratio Bm/Bo in the single-solenoid magnet is 30%lower than that in the conventional six-solenoid magnet. This tolerates higher rated superconducting current in the coil. The Lorentz force of the coil in the single-solenoid system is also much lower than in the six-solenoid system. This novel type of magnet possesses significant advantage over conventional magnets, especially when used as a super-high field functional magnetic resonance imaging magnet.

  6. Identifying the source of super-high energetic electrons in the presence of pre-plasma in laser-matter interaction at relativistic intensities

    CERN Document Server

    Wu, D; Luan, S X; Yu, W

    2015-01-01

    The generation of super-high energetic electrons influenced by pre-plasma in relativistic intensity laser matter interaction is studied in a one-dimensional slab approximation with particle-in-cell simulations. Different pre-plasma scale-lengths of $1\\ \\mu\\text{m}$, $5\\ \\mu\\text{m}$, $10\\ \\mu\\text{m}$ and $15\\ \\mu\\text{m}$ are considered, showing an increase in both particle number and cut-off kinetic energy of energetic electrons with the increase of pre-plasma scale-length, and the obtained cut-off electron energies greatly exceeding the ponderomotive energies. A two-stage electron acceleration model is proposed to explain the underlying physics. The first stage is attributed to the synergetic acceleration by longitudinal electric field and laser pulse, with the efficiency depending on the pre-plasma scale-length. The fast electrons pre-accelerated in the first stage could build up an intense electrostatic potential with the potential energy several times as large of the initial electron kinetic energy. Par...

  7. Super-aligned carbon nanotube films with a thin metal coating as highly conductive and ultralight current collectors for lithium-ion batteries

    Science.gov (United States)

    Wang, Ke; Wu, Yang; Wu, Hengcai; Luo, Yufeng; Wang, Datao; Jiang, Kaili; Li, Qunqing; Li, Yadong; Fan, Shoushan; Wang, Jiaping

    2017-05-01

    Cross-stacked super-aligned carbon nanotube (SACNT) films are promising for use as current collectors in lithium-ion batteries because of their outstanding capability to decrease the weight and thickness of inactive material and strong adhesion to the electrodes. However, the relatively poor conductivity of SACNT films may limit their application to large-size electrodes or at high current rate. Herein, a facile approach is proposed to improve the conductivity of SACNT films by electron-beam deposition of a thin metal film on their surface. Such modification lowers the sheet resistance by three orders of magnitude while keeping the extremely small fraction of SACNT current collectors. The metal-coated SACNT films strongly inhibit polarization during the electrochemical reaction, resulting in improved cell performance compared with that of metal and uncoated CNT current collectors. The improvement in conductivity and cell performance achieved by this approach is so large that the effect of the increase of inactive material is overwhelmed, leading to increased gravimetric energy density.

  8. Identifying the source of super-high energetic electrons in the presence of pre-plasma in laser-matter interaction at relativistic intensities

    Science.gov (United States)

    Wu, D.; Krasheninnikov, S. I.; Luan, S. X.; Yu, W.

    2017-01-01

    The generation of super-high energetic electrons influenced by pre-plasma in relativistic intensity laser-matter interaction is studied in a one-dimensional slab approximation with particle-in-cell simulations. Different pre-plasma scale lengths and laser intensities are considered, showing an increase in both particle number and cut-off kinetic energy of electrons with the increase of pre-plasma scale length and laser intensity, the cut-off kinetic energy greatly exceeding the corresponding laser ponderomotive energy. A two-stage electron acceleration model is proposed to explain the underlying physics. The first stage is attributed to the synergetic acceleration by longitudinal electric field and counter-propagating laser pulses, and a scaling law is obtained with efficiency depending on the pre-plasma scale length and laser intensity. These electrons pre-accelerated in the first stage could build up an intense electrostatic potential barrier with maximal value several times as large as the initial electron kinetic energy. Some of the energetic electrons could be further accelerated by reflection off the electrostatic potential barrier, with their finial kinetic energies significantly higher than the values pre-accelerated in the first stage.

  9. A super-high throughput implementation of MD5 algorithm on FPGA%超高吞吐量MD5算法的FPGA实现

    Institute of Scientific and Technical Information of China (English)

    王臣; 袁焱

    2011-01-01

    In this paper, a novel architecture is proposed to increase the performance of MD5 computing in FPGA , which can achieve a super-high throughput. The scheme is based on full-pipeline for MD5 implementation. Moreover, FIFO cache structure is used for data storage and cooperative computing. The results of simulation and implementation show that the scheme can achieve the theoretical upper bound on throughput. And based on the same platform of FPGA, it outperforms the published scheme with best performance in terms of 77% higher throughput.%为了提高MD5算法在FPGA中实现的运算效率,使之达到超高的数据吞吐量,提出了一种新的全流水线架构,用于实现MD5算法.架构中使用了FIFO缓存存储数据,以配合流水线的运算.实验验证其达到了单个MD5运算单元运算吞吐量的理论上限,在相同芯片平台上,超过已发表的MD5运算模块最高吞吐量的77%.

  10. High dynamic range measurement of spectral responsivity and linearity of a radiation thermometer using a super-continuum laser and LEDs

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Y. S.; Lee, D. H.; Park, C. W.; Park, S. N. [Korea Research Institute of Standards and Science 209 Gajeong-Ro, Yuseong-Gu, Daejon 305-340 (Korea, Republic of)

    2013-09-11

    To realize the temperature scale above the freezing point of silver according to the definition of ITS-90, the dynamic range of the spectral responsivity is one of the most important factors which limit its uncertainty. When the residual spectral response at both side bands of a spectral band is not negligible, a significant uncertainty can be caused by a low dynamic range of the spectral responsivity measurement. In general, incandescent lamps are used to measure the spectral responsivity and the linearity. The dynamic range of the spectral responsivity measurement is often limited by a trade-off with the desired spectral resolution, which is less than 6 decades. Nonlinearity is another limiting fact of uncertainties of the temperature scale. Tungsten lamps have disadvantage in the nonlinearity measurements in terms of adjustability of radiance level and spectral selectivity. We report spectral responsivity measurements of which the measurable dynamic range is enhanced 50 times after replacing a QTH lamp with a super continuum laser. We also present a spectrally selected linearity measurement over a wide dynamic range using high-brightness light emitting diode arrays to observe a slight saturation of linearity.

  11. Generation of warm dense matter and strongly coupled plasmas using the High Radiation on Materials facility at the CERN Super Proton Synchrotron

    CERN Document Server

    Tahir, N A; Brugger, M; Assmann, R; Shutov, A; Lomonosov, I V; Gryaznov, V; Piriz, A R; Udrea, S; Hoffmann, D H H; Fortov, V E; Deutsch, C

    2009-01-01

    A dedicated facility named High Radiation on Materials (HiRadMat) is being constructed at CERN to study the interaction of the 450 GeV protons generated by the Super Proton Synchrotron (SPS) with fixed solid targets of different materials. The main purpose of these future experiments is to study the generation and propagation of thermal shock waves in the target in order to assess the damage caused to the equipment, including collimators and absorbers, in case of an accident involving an uncontrolled release of the entire beam at a given point. Detailed numerical simulations of the beam-target interaction of several cases of interest have been carried out. In this paper we present simulations of the thermodynamic and the hydrodynamic response of a solid tungsten cylindrical target that is facially irradiated with the SPS beam with nominal parameters. These calculations have been carried out in two steps. First, the energy loss of the protons is calculated in the solid target using the FLUKA code (Fasso et al....

  12. HIGHLY SENSITIVE TIMER-BASED RESISTANCE DEVIATION TO TIME CONVERTER

    Directory of Open Access Journals (Sweden)

    Sheroz Khan

    2012-02-01

    Full Text Available Based on an inexpensive popular precision timing chip 555 timer, a resistance to time converter is proposed in this paper which is indeed capable of converting resistive and capacitive changes into pulse widths of proportional durations. This converter exhibits a compatibility of wider conversion range with a reasonable level of sensitivity required for industrial applications. The circuit is expected to have utility in oil and water supply schemes. Simulated results are shown to be compared with mathematical derivations, both reporting a good level of resemblance and similarities.

  13. High order sensitivity analysis of complex, coupled systems

    Science.gov (United States)

    Sobieszczanski-Sobieski, Jaroslaw

    1990-01-01

    The Sobieszczanski-Sobieski (1988) algorithm is extended to include second- and higher-order derivatives while retaining the obviation of finite-differencing of the system analysis. This is accomplished by means of a recursive application of the same implicit function theorem as in the original algorithm. In optimization, the computational cost of the higher-order derivatives is relative to the aggregate cost of analysis together with a repetition of the first-order sensitivity analysis as often as is required to produce the equivalent information by successive linearizations within move limits.

  14. Analysis of Cyberbullying Sensitivity Levels of High School Students and Their Perceived Social Support Levels

    Science.gov (United States)

    Akturk, Ahmet Oguz

    2015-01-01

    Purpose: The purpose of this paper is to determine the cyberbullying sensitivity levels of high school students and their perceived social supports levels, and analyze the variables that predict cyberbullying sensitivity. In addition, whether cyberbullying sensitivity levels and social support levels differed according to gender was also…

  15. Analysis of Cyberbullying Sensitivity Levels of High School Students and Their Perceived Social Support Levels

    Science.gov (United States)

    Akturk, Ahmet Oguz

    2015-01-01

    Purpose: The purpose of this paper is to determine the cyberbullying sensitivity levels of high school students and their perceived social supports levels, and analyze the variables that predict cyberbullying sensitivity. In addition, whether cyberbullying sensitivity levels and social support levels differed according to gender was also…

  16. Sensitivity analysis for high accuracy proximity effect correction

    Science.gov (United States)

    Thrun, Xaver; Browning, Clyde; Choi, Kang-Hoon; Figueiro, Thiago; Hohle, Christoph; Saib, Mohamed; Schiavone, Patrick; Bartha, Johann W.

    2015-10-01

    A sensitivity analysis (SA) algorithm was developed and tested to comprehend the influences of different test pattern sets on the calibration of a point spread function (PSF) model with complementary approaches. Variance-based SA is the method of choice. It allows attributing the variance of the output of a model to the sum of variance of each input of the model and their correlated factors.1 The objective of this development is increasing the accuracy of the resolved PSF model in the complementary technique through the optimization of test pattern sets. Inscale® from Aselta Nanographics is used to prepare the various pattern sets and to check the consequences of development. Fraunhofer IPMS-CNT exposed the prepared data and observed those to visualize the link of sensitivities between the PSF parameters and the test pattern. First, the SA can assess the influence of test pattern sets for the determination of PSF parameters, such as which PSF parameter is affected on the employments of certain pattern. Secondly, throughout the evaluation, the SA enhances the precision of PSF through the optimization of test patterns. Finally, the developed algorithm is able to appraise what ranges of proximity effect correction is crucial on which portion of a real application pattern in the electron beam exposure.

  17. Development of a high sensitive MEMS hydrophone using PVDF

    Science.gov (United States)

    Varadan, Vijay K.; Zhu, Bei; K. A, Jose

    2002-05-01

    The design and experimental evaluation of a PVDF-based MEMS hydrophone is presented in this paper. The basic structure of the hydrophone was fabricated on a silicon wafer using standard NMOS process technology. A MOSFET with extended gate electrode was designed as the interface circuit to the sensing material, which is a piezoelectric polymer, polyvinylidene difluoride (PVDF). Acoustic impedance possessed by this piezoelectric material provides a reasonable match to water, which makes it very attractive for underwater applications. The electrical signal generated by the PVDF film was directly coupled to the gate of the MOSFET. To minimize the parasitic capacitance underneath the PVDF film and hence improve the device sensitivity, a thick photoresist was first employed as the dielectric layer under the extended gate electrode. For underwater operation, a waterproof Rho-C rubber encapsulated the hydrophone. A silicon nitride layer passivated the active device, which is a good barrier material to most mobile ions and solvents. The device after passivation also shows a lower noise level. The theoretical model developed to predict the sensitivity of the hydrophone shows a reasonable agreement between the theory and the experiment.

  18. Photothermal Microscopy for High Sensitivity and High Resolution Absorption Contrast Imaging of Biological Tissues

    Directory of Open Access Journals (Sweden)

    Jun Miyazaki

    2017-04-01

    Full Text Available Photothermal microscopy is useful to visualize the distribution of non-fluorescence chromoproteins in biological specimens. Here, we developed a high sensitivity and high resolution photothermal microscopy with low-cost and compact laser diodes as light sources. A new detection scheme for improving signal to noise ratio more than 4-fold is presented. It is demonstrated that spatial resolution in photothermal microscopy is up to nearly twice as high as that in the conventional widefield microscopy. Furthermore, we demonstrated the ability for distinguishing or identifying biological molecules with simultaneous muti-wavelength imaging. Simultaneous photothermal and fluorescence imaging of mouse brain tissue was conducted to visualize both neurons expressing yellow fluorescent protein and endogenous non-fluorescent chromophores.

  19. Acoustic Sensitivity Analysis on Dominant Transmission Paths for Noise Reduction Design of Super-large Crude Carrier%超大型油轮降噪设计主传递路径族灵敏度方法

    Institute of Scientific and Technical Information of China (English)

    高处; 杨德庆

    2014-01-01

    针对振动噪声传递路径降噪设计是提高船舶声学性能的有效措施之一。目标舱室振动噪声传递路径并不唯一,其中多条主要路径传递了大部分振动与噪声能量。利用作者提出的基于声振熵概念及图论中K则最短路径理论的声振熵赋权图法,能够快速识别船舶舱室噪声主要传递路径族。在此基础上,计算噪声主传递路径族上声学设计参数变化对目标舱室声压影响的灵敏度,调整有关声学设计措施,此即降噪设计主传递路径族灵敏度方法。提出适用于大型船舶噪声主传递路径分析及主传递路径族灵敏度的降噪设计通用流程,通过超大型油轮降噪声学设计实例,说明了该方法的有效性。%One of the effective measures to improve the acoustic performance of ships is to perform a noise reduction design along the sound transmission path. However, there are usually several transmission paths to the target cabin, of which some dominant paths transmit a large amount of noise and vibration energy. Using the proposed vibro-acoustical entropy weighted graph method based on the vibro-acoustical entropy concept and K shortest path theory, the dominant transmission paths of the cabin noise can be identified quickly. On this basis, the sensitivity of influence of the change of the acoustic design parameters of the dominant transmission paths on the sound pressure of the target cabin is calculated. And the method for noise reduction design can be adjusted and determined efficiently. This is known as the sensitivity method of dominant transmission paths in noise reduction design. A general program of this method for noise reduction design of large ships is designed. A numerical example of a super large crude carrier is given and the results show the effectiveness of this method.

  20. High temperature probe sensor with high sensitivity based on Michelson interferometer

    Science.gov (United States)

    Zhao, Na; Fu, Haiwei; Shao, Min; Yan, Xu; Li, Huidong; Liu, Qinpeng; Gao, Hong; Liu, Yinggang; Qiao, Xueguang

    2015-05-01

    A novel Michelson interferometer based on a bi-taper is achieved. Such a device is fabricated by splicing a section of thin core fiber (TCF) at one end of single-mode fiber (SMF). Due to the fiber bi-taper at the splicing point of SMF and TCF, the light is coupled into the fiber core and cladding from lead in fiber core. The light will be reflected at the end of the fiber and then will be recoupled back into the lead out fiber core by the fiber bi-taper. While the light returns back to the lead out fiber, the intermodal interference will occur for the optical path difference between core mode and cladding mode. A high temperature sensitivity of 0.140 nm/°C is achieved from 30 to 800 °C, and the linearity is 99.9%. The configuration features the advantages of easy fabrication, a compact size, high sensitivity, wide sensing range and high mechanical strength, making it a good candidate for distant temperature sensing and oil prospecting.

  1. Super-hybrid composites - An emerging structural material

    Science.gov (United States)

    Chamis, C. C.; Lark, R. F.; Sullivan, T. L.

    1975-01-01

    Specimens of super-hybrids and advanced fiber composites were subjected to extensive tests to determine their mechanical properties, including impact and thermal fatigue. The super-hybrids were fabricated by a procedure similar to that reported by Chamis et al., (1975). Super-hybrids subjected to 1000 cycles of thermal fatigue from -100 to 300 F retained over 90% of their longitudinal flexural strength and over 75% of their transverse flexural strength; their transverse flexural strength may be as high as 8 times that of a commercially supplied boron/1100-Al composite. The thin specimen Izod longitudinal impact resistance of the super-hybrids was twice that of the boron/110-Al material. Super-hybrids subjected to transverse tensile loads exhibited nonlinear stress-strain relationships. The experimentally determined initial membrane (in-plane) and bending elastic properties of super-hybrids were predicted adequately by linear laminate analysis.

  2. High throughput 3D super-resolution microscopy reveals Caulobacter crescentus in vivo Z-ring organization.

    Science.gov (United States)

    Holden, Seamus J; Pengo, Thomas; Meibom, Karin L; Fernandez Fernandez, Carmen; Collier, Justine; Manley, Suliana

    2014-03-25

    We created a high-throughput modality of photoactivated localization microscopy (PALM) that enables automated 3D PALM imaging of hundreds of synchronized bacteria during all stages of the cell cycle. We used high-throughput PALM to investigate the nanoscale organization of the bacterial cell division protein FtsZ in live Caulobacter crescentus. We observed that FtsZ predominantly localizes as a patchy midcell band, and only rarely as a continuous ring, supporting a model of "Z-ring" organization whereby FtsZ protofilaments are randomly distributed within the band and interact only weakly. We found evidence for a previously unidentified period of rapid ring contraction in the final stages of the cell cycle. We also found that DNA damage resulted in production of high-density continuous Z-rings, which may obstruct cytokinesis. Our results provide a detailed quantitative picture of in vivo Z-ring organization.

  3. Highly sensitive methods for electroanalytical chemistry based on nanotubule membranes.

    Science.gov (United States)

    Kobayashi, Y; Martin, C R

    1999-09-01

    Two new methods of electroanalysis are described. These methods are based on membranes containing monodisperse Au nanotubules with inside diameters approaching molecular dimensions. In one method, the analyte species is detected by measuring the change in trans-membrane current when the analyte is added to the nanotubule-based cell. The second method entails the use of a concentration cell based on the nanotubule membrane. In this case, the change in membrane potential is used to detect the analyte. Detection limits as low as 10(-11) M have been achieved. Hence, these methods compete with even the most sensitive of modern analytical methodologies. In addition, excellent molecular-sized-based selectivity is observed.

  4. A new compact, high sensitivity neutron imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Caillaud, T.; Landoas, O.; Briat, M.; Rosse, B.; Thfoin, I.; Philippe, F.; Casner, A.; Bourgade, J. L.; Disdier, L. [CEA, DAM, DIF,F-91297 Arpajon (France); Glebov, V. Yu.; Marshall, F. J.; Sangster, T. C. [Laboratory for Laser Energetics, University of Rochester, 250 East River Road, Rochester, New York 14623-1299 (United States); Park, H. S.; Robey, H. F.; Amendt, P. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2012-10-15

    We have developed a new small neutron imaging system (SNIS) diagnostic for the OMEGA laser facility. The SNIS uses a penumbral coded aperture and has been designed to record images from low yield (10{sup 9}-10{sup 10} neutrons) implosions such as those using deuterium as the fuel. This camera was tested at OMEGA in 2009 on a rugby hohlraum energetics experiment where it recorded an image at a yield of 1.4 Multiplication-Sign 10{sup 10}. The resolution of this image was 54 {mu}m and the camera was located only 4 meters from target chamber centre. We recently improved the instrument by adding a cooled CCD camera. The sensitivity of the new camera has been fully characterized using a linear accelerator and a {sup 60}Co {gamma}-ray source. The calibration showed that the signal-to-noise ratio could be improved by using raw binning detection.

  5. Carbon nanotube quantum dots as highly sensitive THz spectrometers

    Science.gov (United States)

    Rinzan, Mohamed; Jenkins, Greg; Drew, Dennis; Shafranjuk, Serhii; Barbara, Paola

    2012-02-01

    We show that carbon nanotube quantum dots (CNT-Dots) coupled to antennas are extremely sensitive, broad-band, terahertz quantum detectors. Their response is due to photon-assisted single-electron tunneling (PASET)[1], but cannot be fully understood with orthodox PASET models[2]. We consider intra-dot excitations and non-equilibrium cooling to explain the anomalous response. REFERENCES: [1] Y. Kawano, S. Toyokawa, T. Uchida and K. Ishibashi, THz photon assisted tunneling in carbon-nanotube quantum dots, Journal of Applied Physics 103, 034307 (2008). [2] P. K. Tien and J. P. Gordon, Multiphoton Process Observed in the Interaction of Microwave Fields with the Tunneling between Superconductor Films, Phys. Rev. 129, 647 (1963).

  6. High-sensitivity observations of solar flare decimeter radiation

    CERN Document Server

    Benz, Arnold O; Monstein, C; Benz, Arnold O.; Messmer, Peter; Monstein, Christian

    2000-01-01

    A new acousto-optic radio spectrometer has observed the 1 - 2 GHz radio emission of solar flares with unprecedented sensitivity. The number of detected decimeter type III bursts is greatly enhanced compared to observations by conventional spectrometers observing only one frequency at the time. The observations indicate a large number of electron beams propagating in dense plasmas. For the first time, we report weak, reversed drifting type III bursts at frequencies above simultaneous narrowband decimeter spikes. The type III bursts are reliable signatures of electron beams propagating downward in the corona, apparently away from the source of the spikes. The observations contradict the most popular spike model that places the spike sources at the footpoints of loops. Conspicuous also was an apparent bidirectional type U burst forming a fish-like pattern. It occurs simultaneously with an intense U-burst at 600-370 MHz observed in Tremsdorf. We suggest that it intermodulated with strong terrestrial interference ...

  7. Highly sensitive biosensors based on water-soluble conjugated polymers

    Institute of Scientific and Technical Information of China (English)

    XU Hui; WU Haiping; FAN Chunhai; LI Wenxin; ZHANG Zhizhou; HE Lin

    2004-01-01

    Conjugated, conductive polymers are a kind of important organic macromolecules, which has found applications in a variety of areas. The application of conjugated polymers in developing fluorescent biosensors represents the merge of polymer sciences and biological sciences. Conjugated polymers are very good light harvesters as well as fluorescent polymers, and they are also "molecular wires". Through elaborate designs, these important features, i.e. efficient light harvesting and electron/energy transfer, can be used as signal amplification in fluorescent biosensors. This might significantly improve the sensitivity of conjugated polymer-based biosensors. In this article, we reviewed the application of conjugated polymers, via either electron transfer or energy transfer, to detections of gene targets, antibodies or enzymes. We also reviewed recent efforts in conjugated polymer-based solid-state sensor designs as well as chip-based multiple target detection. Possible directions in this conjugated polymer-based biosensor area are also discussed.

  8. Highly sensitive urea sensing with ion-irradiated polymer foils

    Energy Technology Data Exchange (ETDEWEB)

    Fink, Dietmar, E-mail: fink@daad-alumni.de [Departamento de Fisica, Universidad Autonoma Metropolitana-Iztapalapa, P.O. Box 55-534, 09340 Mexico, D.F. (Mexico); Nuclear Physics Institute, Academy of Sciences of the Czech Republic, 250 68 Rez (Czech Republic); Munoz Hernandez, Gerardo [Departamento de Fisica, Universidad Autonoma Metropolitana-Iztapalapa, P.O. Box 55-534, 09340 Mexico, D.F. (Mexico); Division de Ciencias Naturales e Ingenieria, Universidad Autonoma Metropolitana-Cuajimalpa, Pedro Antonio de los Santos 84, Col. Sn. Miguel Chapultepec, C.P. 11850, Mexico, D.F. (Mexico); Alfonta, Lital, E-mail: alfontal@bgu.ac.il [Avram and Stella Goldstein-Goren Department of Biotechnology Engineering, Ben-Gurion University of the Negev, P.O. Box 653, Beer-Sheva 84105 (Israel)

    2012-02-15

    Recently we prepared urea-sensors by attaching urease to the inner walls of etched ion tracks within thin polymer foil. Here, alternative track-based sensor configurations are examined where the enzyme remained in solution. The conductivities of systems consisting of two parallel irradiated polymer foils and confining different urea/urease mixtures in between were examined. The correlations between conductivity and urea concentration differed strongly for foils with unetched and etched tracks, which points at different sensing mechanisms - tentatively attributed to the adsorption of enzymatic reaction products on the latent track entrances and to the enhanced conductivity of reaction product-filled etched tracks, respectively. All examined systems enable in principle, urea sensing. They point at the possibility of sensor cascade construction for more sensitive or selective sensor systems.

  9. Recent advances in high performance poly(lactide): From ``green'' plasticization to super-tough materials via (reactive) compounding

    Science.gov (United States)

    Kfoury, Georgio; Raquez, Jean-Marie; Hassouna, Fatima; Odent, Jérémy; Toniazzo, Valérie; Ruch, David; Dubois, Philippe

    2013-12-01

    Due to its origin from renewable resources, its biodegradability, and recently, its industrial implementation at low costs, poly(lactide) (PLA) is considered as one of the most promising ecological, bio-sourced and biodegradable plastic materials to potentially and increasingly replace traditional petroleum derived polymers in many commodity and engineering applications. Beside its relatively high rigidity (high tensile strength and modulus compared with many common thermoplastics such as poly(ethylene terephthalate) (PET), high impact poly(styrene) (HIPS) and poly(propylene) (PP)), PLA suffers from an inherent brittleness, which can limit its applications especially where mechanical toughness such as plastic deformation at high impact rates or elongation is required. Therefore, the curve plotting stiffness vs. impact resistance and ductility must be shifted to higher values for PLA-based materials, while being preferably fully bio-based and biodegradable upon the application. This review aims to establish a state of the art focused on the recent progresses and preferably economically viable strategies developed in the literature for significantly improve the mechanical performances of PLA. A particular attention is given to plasticization as well as to impact resistance modification of PLA in the case of (reactive) blending PLA-based systems.

  10. Ultra-High Energy Cosmic Particles studies from space: super-EUSO, a possible next-generation experiment

    CERN Document Server

    Petrolini, Alessandro

    2009-01-01

    After the Pierre Auger Observatory, it is likely that space-based experiments might be required for next-generation studies of Ultra-High Energy Cosmic Particles. An overview of this challenging task is presented, emphasizing the main design issues, the criticalities and the intermediate steps required to make this challenging task a reality.

  11. High-efficiency super capacitors based on hetero-structured α-MnO{sub 2} nanorods

    Energy Technology Data Exchange (ETDEWEB)

    Ghouri, Zafar Khan [Department of BIN Fusion Technology, Chonbuk National University, Jeonju 561-756 (Korea, Republic of); Department of Organic materials and Fiber Engineering, Chonbuk National University, Jeonju 561-756 (Korea, Republic of); Shaheer Akhtar, M. [New & Renewable Energy Material Development Center (NewREC), Chonbuk National University, Jeonbuk (Korea, Republic of); Zahoor, Awan [Department of Chemical Engineering, NED University of Engineering & Technology, University Road, Karachi 75270 (Pakistan); Barakat, Nasser A.M., E-mail: nasser@jbnu.ac.kr [Department of Organic materials and Fiber Engineering, Chonbuk National University, Jeonju 561-756 (Korea, Republic of); Department of Chemical Engineering, Faculty of Engineering, El-Minia University, El-Minia (Egypt); Han, Weidong [Department of BIN Fusion Technology, Chonbuk National University, Jeonju 561-756 (Korea, Republic of); Park, Mira [Department of Organic materials and Fiber Engineering, Chonbuk National University, Jeonju 561-756 (Korea, Republic of); Pant, Bishweshwar; Saud, Prem Singh; Lee, Cho Hye [Department of BIN Fusion Technology, Chonbuk National University, Jeonju 561-756 (Korea, Republic of); Kim, Hak Yong, E-mail: khy@jbnu.ac.kr [Department of BIN Fusion Technology, Chonbuk National University, Jeonju 561-756 (Korea, Republic of)

    2015-09-05

    Highlights: • Hetero-structured α-MnO{sub 2} nanorods are prepared by a facile hydrothermal route. • It is applied as active electrode materials for supercapacitor. • A high specific capacitance of 298 Fg{sup −1} with a superior long term cyclic stability is achieved. • Supercapacitor shows high specific capacitance retention 94% after 1000 cycles. - Abstract: Hetero-structured manganese dioxide nanorods with α phase (α-MnO{sub 2}) were prepared by a facile hydrothermal route at low temperature. X-ray diffraction, scanning electron microscopy, transmission electron microscopy and nitrogen adsorption–desorption measurements were used to characterize the prepared hetero-structured α-MnO{sub 2} nanorods. Supercapacitive performance of the hetero-structured α-MnO{sub 2} nanomaterials as active electrode material was evaluated by cyclic voltammetry (CV) in alkaline medium. The MnO{sub 2} hetero-structure with 2 × 2 tunnels constructed from double chains of octahedral [MnO{sub 6}] structure yield a significantly high specific capacitance of 298 Fg{sup −1} at 5 mV s{sup −1} and demonstrated a superior long term cyclic stability, with specific capacitance retention about 94% after 1000 cycles. The superior supercapacitive performance of the hetero-structured α-MnO{sub 2} electrode is due to its high specific surface area and unique hierarchy architecture which facilitate fast electron and ion transport.

  12. Fuel Cell Power System and Equipment Bay for High Altitude, Super- Pressured, Powered Aerostat (HASPA) Operational Manual

    Science.gov (United States)

    1975-05-20

    Identify hy block number) Fuel cell High altitude Power system Aerostat f HASPA Manual .A8SRACt (Continue on reverse aide If rI coeeary and identify...Control Unit 37 VI. Pin Identification - Fuel Cell Control Unit 38 VIH . Pin Identification - Fuel Cell Auxiliary Data Unit 39 - VIII. HASPA - Equipment

  13. Recent advances in high performance poly(lactide): from "green" plasticization to super-tough materials via (reactive) compounding.

    Science.gov (United States)

    Kfoury, Georgio; Raquez, Jean-Marie; Hassouna, Fatima; Odent, Jérémy; Toniazzo, Valérie; Ruch, David; Dubois, Philippe

    2013-01-01

    Due to its origin from renewable resources, its biodegradability, and recently, its industrial implementation at low costs, poly(lactide) (PLA) is considered as one of the most promising ecological, bio-sourced and biodegradable plastic materials to potentially and increasingly replace traditional petroleum derived polymers in many commodity and engineering applications. Beside its relatively high rigidity [high tensile strength and modulus compared with many common thermoplastics such as poly(ethylene terephthalate) (PET), high impact poly(styrene) (HIPS) and poly(propylene) (PP)], PLA suffers from an inherent brittleness, which can limit its applications especially where mechanical toughness such as plastic deformation at high impact rates or elongation is required. Therefore, the curve plotting stiffness vs. impact resistance and ductility must be shifted to higher values for PLA-based materials, while being preferably fully bio-based and biodegradable upon the application. This review aims to establish a state of the art focused on the recent progresses and preferably economically viable strategies developed in the literature for significantly improve the mechanical performances of PLA. A particular attention is given to plasticization as well as to impact resistance modification of PLA in the case of (reactive) blending PLA-based systems.

  14. Recent advances in high performance poly(lactide: From green plasticization to super-tough materials via (reactive compounding

    Directory of Open Access Journals (Sweden)

    Georgio eKfoury

    2013-12-01

    Full Text Available Due to its origin from renewable resources, its biodegradability, and recently, its industrial implementation at low costs, poly(lactide (PLA is considered as one of the most promising ecological, bio-sourced and biodegradable plastic materials to potentially and increasingly replace traditional petroleum derived polymers in many commodity and engineering applications. Beside its relatively high rigidity (high tensile strength and modulus compared with many common thermoplastics such as poly(ethylene terephthalate (PET, high impact poly(styrene (HIPS and poly(propylene (PP, PLA suffers from an inherent brittleness, which can limit its applications especially where mechanical toughness such as plastic deformation at high impact rates or elongation is required. Therefore, the curve plotting stiffness vs. impact resistance and ductility must be shifted to higher values for PLA-based materials, while being preferably fully bio-based and biodegradable upon the application.This review aims to establish a state of the art focused on the recent progresses and preferably economically viable strategies developed in the literature for significantly improve the mechanical performances of PLA. A particular attention is given to plasticization as well as to impact resistance modification of PLA in the case of (reactive blending PLA-based systems.

  15. 超高层钢结构建筑施工工艺控制要点%The construction technology control key points of super high-rise steel structure buildings

    Institute of Scientific and Technical Information of China (English)

    郭锐; 刘刚彬

    2012-01-01

    This paper briefly introduced the present situation of super high-rise steel structure building,and elaborated in detail its construction technology,and combining with specific project example,this paper described the quality control key points of some key process in steel structure construction process,had significance to facilitate the construction level of future super high-rise steel structure buildings.%简要介绍了超高层钢结构建筑现状,对其施工工艺作了具体阐述,并结合具体工程实例,对钢结构工程施工过程中一些关键工序的质量控制要点进行了说明,对促进今后超高层建筑钢结构施工水平具有指导意义。

  16. Super-energy-saving dewatering method for high-specific-surface-area fuels by using dimethyl ether

    Energy Technology Data Exchange (ETDEWEB)

    Kanda, H. [Central Research Institute for Electric Power Industry, Kanagawa (Japan)

    2008-07-01

    There is a growing need for the economical dewatering of high-specific-surface-area fuels containing large amounts of water, such as coal and sewage sludge. The principle underlying conventional dewatering methods is evaporation of the water content by heating the fuels to a high temperature, but this approach consumes a considerable amount of energy. The Central Research Institute of the Electric Power Industry (CRIEPI) has developed a method for the extraction of this water through the use of dimethyl ether (DME), which liquefies at ordinary temperatures under the influence of a slight pressure. In this method, the water content in the fuel is extracted into the liquefied DME for separation from the fuel. After dewatering, the DME is depressurised, and subsequently vaporised, thereby leaving the separated water. Dewatering with an input energy of only 1109 kJ/kg water under ordinary conditions has been demonstrated theoretically.

  17. In-Situ Welding Carbon Nanotubes into a Porous Solid with Super-High Compressive Strength and Fatigue Resistance

    OpenAIRE

    2015-01-01

    Carbon nanotube (CNT) and graphene-based sponges and aerogels have an isotropic porous structure and their mechanical strength and stability are relatively lower. Here, we present a junction-welding approach to fabricate porous CNT solids in which all CNTs are coated and welded in situ by an amorphous carbon layer, forming an integral three-dimensional scaffold with fixed joints. The resulting CNT solids are robust, yet still highly porous and compressible, with compressive strengths up to 72...

  18. In-Situ Welding Carbon Nanotubes into a Porous Solid with Super-High Compressive Strength and Fatigue Resistance

    Science.gov (United States)

    Lin, Zhiqiang; Gui, Xuchun; Gan, Qiming; Chen, Wenjun; Cheng, Xiaoping; Liu, Ming; Zhu, Yuan; Yang, Yanbing; Cao, Anyuan; Tang, Zikang

    2015-06-01

    Carbon nanotube (CNT) and graphene-based sponges and aerogels have an isotropic porous structure and their mechanical strength and stability are relatively lower. Here, we present a junction-welding approach to fabricate porous CNT solids in which all CNTs are coated and welded in situ by an amorphous carbon layer, forming an integral three-dimensional scaffold with fixed joints. The resulting CNT solids are robust, yet still highly porous and compressible, with compressive strengths up to 72 MPa, flexural strengths up to 33 MPa, and fatigue resistance (recovery after 100,000 large-strain compression cycles at high frequency). Significant enhancement of mechanical properties is attributed to the welding-induced interconnection and reinforcement of structural units, and synergistic effects stemming from the core-shell microstructures consisting of a flexible CNT framework and a rigid amorphous carbon shell. Our results provide a simple and effective method to manufacture high-strength porous materials by nanoscale welding.

  19. Comparison of super-high-energy-propulsion-systems based on metallic hydrogen propellant for ES to LEO space transportation

    Science.gov (United States)

    Thierschmann, M.

    1990-01-01

    The application is studied of metallic H2 as a rocket propellant, which contains a specific energy of about 52 kcal/g in theory yielding a maximum specific impulse of 1700 s. With the convincing advantage of having a density 14 times that of conventional liquid H2/liquid O2 propellants, metallic H2 could satisfy the demands of advanced launch vehicle propulsion for the next millennium. Provided that there is an atomic metallic state of H2, and that this state is metastable at ambient pressure, which still is not proven, the results are given of the study of some important areas, which concern the production of metallic H2, the combustion, chamber cooling, and storage. The results show that the use of metallic H2 as rocket propellant could lead to revolutionary changes in space vehicle philosophy toward small size, small weight, and high performance single stage to orbit systems. The use of high metallic H2 mass fractions results in a dramatic reduction of required propellant volume, while gas temperatures in the combustion chamber exceed 5000 K. Furthermore, it follows, that H2 (liquid or slush) is the most favorable candidate as working fluid. Jet generated noise due to high exhaust velocities could be a problem.

  20. Raspberry Pi super cluster

    CERN Document Server

    Dennis, Andrew K

    2013-01-01

    This book follows a step-by-step, tutorial-based approach which will teach you how to develop your own super cluster using Raspberry Pi computers quickly and efficiently.Raspberry Pi Super Cluster is an introductory guide for those interested in experimenting with parallel computing at home. Aimed at Raspberry Pi enthusiasts, this book is a primer for getting your first cluster up and running.Basic knowledge of C or Java would be helpful but no prior knowledge of parallel computing is necessary.

  1. High-sensitivity in situ QCLAS-based ammonia concentration sensor for high-temperature applications

    Science.gov (United States)

    Peng, W. Y.; Sur, R.; Strand, C. L.; Spearrin, R. M.; Jeffries, J. B.; Hanson, R. K.

    2016-07-01

    A novel quantum cascade laser (QCL) absorption sensor is presented for high-sensitivity in situ measurements of ammonia (hbox {NH}_3) in high-temperature environments, using scanned wavelength modulation spectroscopy (WMS) with first-harmonic-normalized second-harmonic detection (scanned WMS-2 f/1 f) to neutralize the effect of non-absorption losses in the harsh environment. The sensor utilized the sQ(9,9) transition of the fundamental symmetric stretch band of hbox {NH}_3 at 10.39 {\\upmu }hbox {m} and was sinusoidally modulated at 10 kHz and scanned across the peak of the absorption feature at 50 Hz, leading to a detection bandwidth of 100 Hz. A novel technique was used to select an optimal WMS modulation depth parameter that reduced the sensor's sensitivity to spectral interference from hbox {H}_2hbox {O} and hbox {CO}_2 without significantly sacrificing signal-to-noise ratio. The sensor performance was validated by measuring known concentrations of hbox {NH}_3 in a flowing gas cell. The sensor was then demonstrated in a laboratory-scale methane-air burner seeded with hbox {NH}_3, achieving a demonstrated detection limit of 2.8 ± 0.26 ppm hbox {NH}_3 by mole at a path length of 179 cm, equivalence ratio of 0.6, pressure of 1 atm, and temperatures of up to 600 K.

  2. Highly sensitive glucose biosensor based on Au-Ni coaxial nanorod array having high aspect ratio.

    Science.gov (United States)

    Hsu, Che-Wei; Wang, Gou-Jen

    2014-06-15

    An effective glucose biosensor requires a sufficient amount of GOx immobilizing on the electrode surface. An electrode of a 3D nanorod array, having a larger surface-to-volume ratio than a 2D nanostructure, can accommodate more GOx molecules to immobilize onto the surface of the nanorods. In this study, a highly sensitive Au-Ni coaxial nanorod array electrode fabricated through the integration of nano electroforming and immersion gold (IG) method for glucose detection was developed. The average diameter of the as-synthesized Ni nanorods and that of the Au-Ni nanorods were estimated to be 150 and 250 nm, respectively; both had a height of 30 μm. The aspect ratio was 120. Compared to that of a flat Au electrode, the effective sensing area was enhanced by 79.8 folds. Actual glucose detections demonstrated that the proposed Au-Ni coaxial nanorod array electrode could operate in a linear range of 27.5 μM-27.5mM with a detection limit of 5.5μM and a very high sensitivity of 769.6 μA mM(-1)cm(-2). Good selectivity of the proposed sensing device was verified by sequential injections of uric acid (UA) and ascorbic acid (AA). Long-term stability was examined through successive detections over a period of 30 days.

  3. Nitrogen detected TROSY at high field yields high resolution and sensitivity for protein NMR

    Energy Technology Data Exchange (ETDEWEB)

    Takeuchi, Koh [National Institute for Advanced Industrial Science and Technology, Molecular Profiling Research Center for Drug Discovery (Japan); Arthanari, Haribabu [Harvard Medical School, Department of Biochemistry and Molecular Pharmacology (United States); Shimada, Ichio, E-mail: shimada@iw-nmr.f.u-tokyo.ac.jp [National Institute for Advanced Industrial Science and Technology, Molecular Profiling Research Center for Drug Discovery (Japan); Wagner, Gerhard, E-mail: gerhard-wagner@hms.harvard.edu [Harvard Medical School, Department of Biochemistry and Molecular Pharmacology (United States)

    2015-12-15

    Detection of {sup 15}N in multidimensional NMR experiments of proteins has sparsely been utilized because of the low gyromagnetic ratio (γ) of nitrogen and the presumed low sensitivity of such experiments. Here we show that selecting the TROSY components of proton-attached {sup 15}N nuclei (TROSY {sup 15}N{sub H}) yields high quality spectra in high field magnets (>600 MHz) by taking advantage of the slow {sup 15}N transverse relaxation and compensating for the inherently low {sup 15}N sensitivity. The {sup 15}N TROSY transverse relaxation rates increase modestly with molecular weight but the TROSY gain in peak heights depends strongly on the magnetic field strength. Theoretical simulations predict that the narrowest line width for the TROSY {sup 15}N{sub H} component can be obtained at 900 MHz, but sensitivity reaches its maximum around 1.2 GHz. Based on these considerations, a {sup 15}N-detected 2D {sup 1}H–{sup 15}N TROSY-HSQC ({sup 15}N-detected TROSY-HSQC) experiment was developed and high-quality 2D spectra were recorded at 800 MHz in 2 h for 1 mM maltose-binding protein at 278 K (τ{sub c} ∼ 40 ns). Unlike for {sup 1}H detected TROSY, deuteration is not mandatory to benefit {sup 15}N detected TROSY due to reduced dipolar broadening, which facilitates studies of proteins that cannot be deuterated, especially in cases where production requires eukaryotic expression systems. The option of recording {sup 15}N TROSY of proteins expressed in H{sub 2}O media also alleviates the problem of incomplete amide proton back exchange, which often hampers the detection of amide groups in the core of large molecular weight proteins that are expressed in D{sub 2}O culture media and cannot be refolded for amide back exchange. These results illustrate the potential of {sup 15}N{sub H}-detected TROSY experiments as a means to exploit the high resolution offered by high field magnets near and above 1 GHz.

  4. 不确定欠驱动系统的高阶自适应Super-Twisting滑模控制%High-Order Adaptive Super-Twisting Sliding Mode Control for Uncertain Underactuated Systems

    Institute of Scientific and Technical Information of China (English)

    杨兴明; 高银平

    2014-01-01

    为实现一类不确定欠驱动系统在未知干扰情况下的鲁棒控制,针对传统滑模控制中存在的抖振问题,提出一种基于二次型Lyapunov函数的二阶Super-Twisting自适应滑模控制策略。首先,控制器的不连续项采用二阶Super-Twisting算法,将不连续控制作用在滑模量的二阶导数。然后,针对滑模面受不确定干扰影响的情况,为调节参数设计一种自适应律方法,该方法不受传统二阶滑模控制中干扰项的一阶导数边界已知的条件限制,保证滑模面在有干扰情况下的收敛,削弱控制器输入的抖振现象。最后,以两轮自平衡车为实验对象验证该方法,并与传统滑模及普通二阶滑模方法做仿真对比。仿真结果表明文中所提的二阶自适应滑模控制方法在控制效果和降低抖振方面表现更优。%To achieve good robustness against disturbances for a class of uncertain underactuated systems, a second-order adaptive sliding mode control method is proposed based on quadratic Lyapunov function to reduce the inherent chattering of conventional sliding mode control ( SMC ) . Firstly, a second-order super-twisting algorithm is used by the discontinuous part of controller, which acts on the second-order derivative of sliding mode variables. Secondly, as for the effects of unknown disturbances on sliding mode surface, an adaptive law is designed to adjust the parameters. This method eliminates the restriction of the first derivative of disturbances boundary being known in the traditional second-order sliding mode control, which not only keeps convergence of sliding mode surface but also reduces chattering. Finally, a two-wheeled self-balancing cart is used to test the proposed approach. The simulation results show that compared with conventional SMC and ordinary second-order SMC, the proposed method outperforms the above methods on effectiveness and reducing chattering.

  5. The optimization of super-high resolution frequency measurement techniques based on phase quantization regularities between any frequencies.

    Science.gov (United States)

    Li, Zhiqi; Zhou, Wei; Zhou, Hui; Zhang, Xueping; Zhao, Jie

    2013-02-01

    Step phase quantization regularity between different nominal frequency signals is introduced in this paper. Based on this regularity, an optimized high resolution frequency measurement technique is presented. The key features and issues of phase quantization characteristics and measurements are described. Based on the relationship between the same or multiple nominal signals with a certain differences, the resolution of frequency measurements is developed and the range is widened. Several measurement results are provided to support the concepts with experimental evidence. The resolution of frequency measurement can reach 10(-12) (s(-1)) over a wide range or higher for specific frequency signals.

  6. High Sensitivity Optomechanical Reference Accelerometer over 10 kHz

    Science.gov (United States)

    2014-06-05

    characterizing fast mechanical dynamics and piezo -electric devices, but typically not both. Yet extremely high resolution maintained over large...applying a ringdown technique in vacuum. To this end, we used a piezo -shaker to excite the oscillator at its resonance frequency and measured the...exponential decay response. The resonance peak was determined by spectral analysis and then honed in by a high resolution function generator driving the piezo

  7. Super-resolution imaging of Escherichia coli nucleoids reveals highly structured and asymmetric segregation during fast growth.

    Science.gov (United States)

    Spahn, Christoph; Endesfelder, Ulrike; Heilemann, Mike

    2014-03-01

    Bacterial replication and chromosome segregation are highly organized both in space and in time. However, spatial analysis is hampered by the resolution limit of conventional fluorescence microscopy. In this study, we incubate rapidly-growing Escherichia coli with 5-ethynyl-2'-deoxyuridine (EdU), label the resulting EdU-DNA with photoswitchable fluorophores, and image incorporated molecules with an average experimental precision of 13 nm. During the segregation process, nucleoids develop highly-defined and cell-cycle dependent hetero-structures, which contain discrete DNA fibers with diameters far below the diffraction limit. Strikingly, these structures appear temporally shifted between sister chromosomes, an asymmetry which accumulates for ongoing replication rounds. Moreover, nucleoid positioning and expansion along the bacterial length axis fit into an elongation-mediated segregation model in fast growing E. coli cultures. This is supported by close proximity of the nucleoids to the bacterial plasma membrane, the nature of the observed hetero-structures and recently found interactions of membrane-associated proteins with DNA.

  8. The Super-TIGER Instrument to Probe Galactic Cosmic Ray Origins

    Science.gov (United States)

    Mitchell, John W.; Binns, W. R.; Bose, R, G.; Braun, D. L.; Christian, E. R.; Daniels, W. M; DeNolfo, G. A.; Dowkontt, P. F.; Hahne, D. J.; Hams, T.; Israel, M. H.; Klemic, J.; Labrador, A. W.; Link, J. T.; Mewaldt, R. A.; Moore, P. R.; Murphy, R. P.; Olevitch, M. A.; Rauch, B. F.; SanSebastian, F.; Sasaki, M.; Simburger, G. E.; Stone, E. C.; Waddington, C. J.

    2011-01-01

    Super-TIGER (Super Trans-Iron Galactic Element Recorder) is under construction for the first of two planned Antarctic long-duration balloon flights in December 2012. This new instrument will measure the abundances of ultra-heavy elements (30Zn and heavier), with individual element resolution, to provide sensitive tests of the emerging model of cosmic-ray origins in OB associations and models of the mechanism for selection of nuclei for acceleration. Super-TIGER builds on the techniques of TIGER, which produced the first well-resolved measurements of elemental abundances of the elements 31Ga, 32Ge, and 34Se. Plastic scintillators together with acrylic and silica-aerogel Cherenkov detectors measure particle charge. Scintillating-fiber hodoscopes track particle trajectories. Super-TIGER has an active area of 5.4 sq m, divided into two independent modules. With reduced material thickness to decrease interactions, its effective geometry factor is approx.6.4 times larger than TIGER, allowing it to measure elements up to 42Mo with high statistical precision, and make exploratory measurements up to 56Ba. Super-TIGER will also accurately determine the energy spectra of the more abundant elements from l0Ne to 28Ni between 0.8 and 10 GeV/nucleon to test the hypothesis that microquasars or other sources could superpose spectral features. We will discuss the implications of Super-TIGER measurements for the study of cosmic-ray origins and will present the measurement technique, design, status, and expected performance, including numbers of events and resolution. Details of the hodoscopes, scintillators, and Cherenkov detectors will be given in other presentations at this conference.

  9. Achieving tunable sensitivity in composite high-energy density materials

    Science.gov (United States)

    Kuklja, Maija M.; Tsyshevsky, Roman V.; Rashkeev, Sergey

    2017-01-01

    Laser irradiation provides a unique opportunity for selective, predictive, and controlled initiation of energetic materials. We propose a consistent micro-scale mechanism of photoexcitation at the interface, formed by a molecular energetic material and a metal oxide. A specific PETN-MgO model composite is used to illustrate and explain seemingly puzzling experiments on selective laser initiation of energetic materials, which reported that the presence of metal oxide additives triggered the photoinitiation by an unusually low energy. We suggest that PETN photodecomposition is catalyzed by oxygen vacancies (F0 centers) at the MgO surface. The proposed model suggests ways to tune sensitivity of energetic molecular materials to photoinitiation. Our quantum-chemical calculations suggest that the structural point defects (e.g., oxygen vacancies) strongly interact with the molecular material (e.g., adsorbed energetic molecules) by inducing a charge transfer at the interface and hence play an imperative role in governing both energy absorption and energy release in the system. Our approach and conclusions provide a solid basis for novel design of energetic interfaces with desired properties and offers a new perspective in the field of explosive materials and devices.

  10. High-sensitivity observations of solar flare decimeter radiation

    Science.gov (United States)

    Benz, A. O.; Messmer, P.; Monstein, C.

    2001-01-01

    A new acousto-optic radio spectrometer has observed the 1-2 GHz radio emission of solar flares with unprecedented sensitivity. The number of detected decimeter type III bursts is greatly enhanced compared to observations by conventional spectrometers observing only one frequency at the time. The observations indicate a large number of electron beams propagating in dense plasmas. For the first time, we report weak, reversed drifting type III bursts at frequencies above simultaneous narrowband decimeter spikes. The type III bursts are reliable signatures of electron beams propagating downward in the corona, apparently away from the source of the spikes. The observations contradict the most popular spike model that places the spike sources at the footpoints of loops. Conspicuous also was an apparent bidirectional type U burst forming a fish-like pattern. It occurs simultaneously with an intense U-burst at 600-370 MHz observed in Tremsdorf. We suggest that it intermodulated with strong terrestrial interference(cellular phones) causing a spurious symmetric pattern in the spectrogram at 1.4 GHz. Symmetric features in the 1-2 GHz range, some already reported in the literature, therefore must be considered with utmost caution.

  11. Assessment of the impact of HTSCs on superconducting fault-current limiters. [High Temperature SuperConductors (HTSCs)

    Energy Technology Data Exchange (ETDEWEB)

    Giese, R.F. (Argonne National Lab., IL (United States)); Runde, M. (Energiforsyningens Forskningsinstitutt A/S, Trondheim (Norway))

    1993-01-01

    The possible impact of nitrogen-cooled superconductors on the desip and cost of superconducting fault-current limiters is assessed by considering the technical specifications such devices must meet and by comparing material properties of 77-K and 4-K superconductors. The main advantages of operating superconductors at 77 K are that the refrigeration operating cost is reduced by a factor of up to 25 and the refrigeration capital cost is reduced by a factor of up to 10. The heat capacity is several orders of magnitude Larger at 77 K and at 4 K. This phenomenon increases conductor stability against flux jumps but makes switching from the superconducting to the normal state slow and difficult. Therefore, a high critical current density, probably at least 10[sup 5] A/cm[sup 2], is required.

  12. Super-miniature multi-hot-film probe for sub-Kolmogorov resolution in high-Re turbulence

    Science.gov (United States)

    Borisenkov, Y.; Kholmyansky, M.; Krylov, S.; Liberzon, A.; Tsinober, A.

    2011-12-01

    The work reported here is motivated by the discovery of far more important role played by the sub-Kolmogorov scales than commonly believed. The first part is devoted to an overview of main results and issues that prompted the present developments. The emphasis is made on a number of manifestations of nonlocal nature of turbulence involving direct and bidirectional coupling of conventionally-defined inertial and dissipative ranges showing (a) that both concepts are ill-posed and (b) that further progress requires sub-Kolmogorov resolution. The second part contains a presentation on design, manufacturing and tests in laboratory of a micro-hot-film sensor using modern micro-fabrication technologies, as a basis for a probe of much smaller scale than available today with access to quantities like vorticity and strain at sub-Kolmogorov scales in high-Reynolds-number flows.

  13. Development of a super high-rate Anammox reactor and in situ analysis of biofilm structure and function.

    Science.gov (United States)

    Tsushima, Ikuo; Ogasawara, Yuji; Shimokawa, Masaki; Kindaichi, Tomonori; Okabe, Satoshi

    2007-01-01

    The anaerobic ammonium oxidation (Anammox) process is a new efficient and cost effective method of ammonium removal from wastewater. Under strictly anoxic condition, ammonium is directly oxidised with nitrite as electron acceptor to dinitrogen gas. However, it is extremely difficult to cultivate Anammox bacteria due to their low growth rate. This suggests that a rapid and efficient start-up of Anammox process is the key to practical applications. To screen appropriate seeding sludge with high Anammox potential, a real-time quantitative PCR assay with newly designed primers has been developed. Thereafter, the seeding sludge with high abundance of Anammox bacteria (1.7 x 10(8) copies/mg-dry weight) was selected and inoculated into an upflow anaerobic biofilters (UABs). The UABs were operated for more than 1 year and the highest nitrogen removal rate of 24.0 kg-N m-3 day(-1) was attained. In addition, the ecophysiology of Anammox bacteria (spatial distribution and in situ activity) in biofilms was analysed by combining a full-cycle 16S rRNA approach and microelectrodes. The microelectrode measurement clearly revealed that a successive vertical zonation of the partial nitrification (NH4+ to NO2-), Anammox reaction and denitrification was developed in the biofilm in the UAB. This result agreed with the spatial distribution of corresponding bacterial populations in the biofilm. We linked the micro-scale information (i.e. single cell and/or biofilm levels) with the macro-scale information (i.e. the reactor level) to understand the details of Anammox reaction occurring in the UABs.

  14. High sensitivity of Giardia duodenalis to tetrahydrolipstatin (orlistat in vitro.

    Directory of Open Access Journals (Sweden)

    Juliane Hahn

    Full Text Available Giardiasis, a gastrointestinal disease caused by Giardia duodenalis, is currently treated mainly with nitroimidazoles, primarily metronidazole (MTZ. Treatment failure rates of up to 20 percent reflect the compelling need for alternative treatment options. Here, we investigated whether orlistat, a drug approved to treat obesity, represents a potential therapeutic agent against giardiasis. We compared the growth inhibitory effects of orlistat and MTZ on a long-term in vitro culture adapted G. duodenalis strain, WB-C6, and on a new isolate, 14-03/F7, from a patient refractory to MTZ treatment using a resazurin assay. The giardiacidal concentration of the drugs and their combined in vitro efficacy was determined by median-effect analysis. Morphological changes after treatment were analysed by light and electron microscopy. Orlistat inhibited the in vitro growth of G. duodenalis at low micromolar concentrations, with isolate 14-03/F7 (IC50(24h = 2.8 µM being more sensitive than WB-C6 (IC50(24h = 6.2 µM. The effect was significantly more potent compared to MTZ (IC50(24h = 4.3 µM and 11.0 µM, respectively and led to specific undulated morphological alterations on the parasite surface. The giardiacidal concentration of orlistat was >14 µM for 14-03/F7 and >43 µM for WB-C6, respectively. Importantly, the combination of both drugs revealed no interaction on their inhibitory effects. We demonstrate that orlistat is a potent inhibitor of G. duodenalis growth in vitro and kills parasites at concentrations achievable in the gut by approved treatment regimens for obesity. We therefore propose to investigate orlistat in controlled clinical studies as a new drug in giardiasis.

  15. High sensitivity of Giardia duodenalis to tetrahydrolipstatin (orlistat) in vitro.

    Science.gov (United States)

    Hahn, Juliane; Seeber, Frank; Kolodziej, Herbert; Ignatius, Ralf; Laue, Michael; Aebischer, Toni; Klotz, Christian

    2013-01-01

    Giardiasis, a gastrointestinal disease caused by Giardia duodenalis, is currently treated mainly with nitroimidazoles, primarily metronidazole (MTZ). Treatment failure rates of up to 20 percent reflect the compelling need for alternative treatment options. Here, we investigated whether orlistat, a drug approved to treat obesity, represents a potential therapeutic agent against giardiasis. We compared the growth inhibitory effects of orlistat and MTZ on a long-term in vitro culture adapted G. duodenalis strain, WB-C6, and on a new isolate, 14-03/F7, from a patient refractory to MTZ treatment using a resazurin assay. The giardiacidal concentration of the drugs and their combined in vitro efficacy was determined by median-effect analysis. Morphological changes after treatment were analysed by light and electron microscopy. Orlistat inhibited the in vitro growth of G. duodenalis at low micromolar concentrations, with isolate 14-03/F7 (IC50(24h) = 2.8 µM) being more sensitive than WB-C6 (IC50(24h) = 6.2 µM). The effect was significantly more potent compared to MTZ (IC50(24h) = 4.3 µM and 11.0 µM, respectively) and led to specific undulated morphological alterations on the parasite surface. The giardiacidal concentration of orlistat was >14 µM for 14-03/F7 and >43 µM for WB-C6, respectively. Importantly, the combination of both drugs revealed no interaction on their inhibitory effects. We demonstrate that orlistat is a potent inhibitor of G. duodenalis growth in vitro and kills parasites at concentrations achievable in the gut by approved treatment regimens for obesity. We therefore propose to investigate orlistat in controlled clinical studies as a new drug in giardiasis.

  16. HIGH SENSITIVE C-REACTIVE PROTEIN IN CEREBROVASCULAR ISCHEMIA

    Directory of Open Access Journals (Sweden)

    Padmalatha

    2016-02-01

    Full Text Available BACKGROUND Cerebrovascular ischemia is recognized as a major health problem, which causes significant morbidity and mortality. The main pathophysiology of ischemic stroke is atherosclerosis of cerebral vessels. Hs-CRP is a sensitive marker of inflammation tissue injury in the arterial wall, which contributes to atherosclerosis. In this study, we aim to investigate the association of hs-CRP in patients with ischemic stroke and to correlate hs-CRP levels with possible risk factors of ischemic stroke and to assess the prognostic value of hs-CRP in ischemic stroke. METHODS In the present case control study after meeting inclusion and exclusion criteria, 50 patients with acute ischemic stroke admitted in the medical ward, King George Hospital, during the period between April 2014 and October 2014 and 40 asymptomatic age and sex matched control subjects were included. RESULTS The mean hs-CRP value in cases is 3.78+5.28mg/dl and in controls is 0.425+0.305mg/dl. Mean hs-CRP value is higher (3.78mg/dl in cases when compared to controls (0.425mg/dl, which is statistically significant. P admitted with severe degree of weakness (0-1/5 power with mean hs-CRP value of 4.28+4.07 without significant improvement in the power at the time of discharge; 8(16%> with mean hs-CRP value of 10.43+7.74 were expired. CONCLUSION Acute ischemic patients had higher mean hs-CRP values when compared to healthy asymptomatic control subjects P0.05. Higher mean hs-CRP values were associated with poor outcome after acute ischemic stroke. P<0.001.

  17. High Sensitivity Indium Phosphide Based Avalanche Photodiode Focal Plane Arrays Project

    Data.gov (United States)

    National Aeronautics and Space Administration — nLight has demonstrated highly-uniform APD arrays based on the highly sensitive InGaAs/InP material system. These results provide great promise for achieving the...

  18. Polycarbonates: a long-term highly sensitive radon monitor

    CERN Document Server

    Pressyanov, D; Poffijn, A; Meesen, G; Deynse, A V

    2000-01-01

    An approach for long-term (either retrospective or prospective) sup 2 sup 2 sup 2 Rn measurements is proposed that is based on the combination of the high radon absorption ability of some polycarbonates with their alpha track-etch properties. The detection limit is projected to be <10 Bq m sup - sup 3 for an exposure time of 20 yr.

  19. "Super Roman Pots"

    CERN Multimedia

    CERN PhotoLab

    1975-01-01

    Remotely controlled re-entrant vacuum vessels, with very thin (0.17 mm) central windows, that will be installed in each downstream arm of intersection I-8. Detectors for a coming physics experiment, placed inside these "Super Roman Pots", can be moved very close to the circulating ISR beams.

  20. A Super Roman Pot

    CERN Multimedia

    1975-01-01

    Remotely controlled re-entrant vacuum vessels, with very thin (0.17 mm) central windows, that were installed in each downstream arm of the ISR intersection I-8. Detectors placed inside these Super Roman Pots could be moved very close to the circulating ISR beams. (See Annual Report 1974 p. 110.)

  1. Mass Spectrometry-based Assay for High Throughput and High Sensitivity Biomarker Verification

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Xuejiang; Tang, Keqi

    2017-06-14

    Searching for disease specific biomarkers has become a major undertaking in the biomedical research field as the effective diagnosis, prognosis and treatment of many complex human diseases are largely determined by the availability and the quality of the biomarkers. A successful biomarker as an indicator to a specific biological or pathological process is usually selected from a large group of candidates by a strict verification and validation process. To be clinically useful, the validated biomarkers must be detectable and quantifiable by the selected testing techniques in their related tissues or body fluids. Due to its easy accessibility, protein biomarkers would ideally be identified in blood plasma or serum. However, most disease related protein biomarkers in blood exist at very low concentrations (<1ng/mL) and are “masked” by many none significant species at orders of magnitude higher concentrations. The extreme requirements of measurement sensitivity, dynamic range and specificity make the method development extremely challenging. The current clinical protein biomarker measurement primarily relies on antibody based immunoassays, such as ELISA. Although the technique is sensitive and highly specific, the development of high quality protein antibody is both expensive and time consuming. The limited capability of assay multiplexing also makes the measurement an extremely low throughput one rendering it impractical when hundreds to thousands potential biomarkers need to be quantitatively measured across multiple samples. Mass spectrometry (MS)-based assays have recently shown to be a viable alternative for high throughput and quantitative candidate protein biomarker verification. Among them, the triple quadrupole MS based assay is the most promising one. When it is coupled with liquid chromatography (LC) separation and electrospray ionization (ESI) source, a triple quadrupole mass spectrometer operating in a special selected reaction monitoring (SRM) mode

  2. Microstructure-Sensitive Modeling of High Cycle Fatigue (Preprint)

    Science.gov (United States)

    2009-03-01

    history ( carburization and shot peening) and resulting residual stresses are considered in the case of subsurface crack formation at primary inclusions...experimental responses for known microstructures. Effects of process history ( carburization and shot peening) and resulting residual stresses are considered...nonmetallic inclusions. 3. HCF Crack Formation in Carburized and Shot Peened Martensitic Gear Steel High strength low carbon martensitic gear steel is a

  3. A highly selective and sensitive fluorescent chemosensor for Zn2+

    Institute of Scientific and Technical Information of China (English)

    Xiu Ying Zhang; Zuo Hui Wang; Lin Yang

    2008-01-01

    A new selective Zn2+ fluorescent chemosensor,o-vanillin-4-ethoxybenzoylhydrazone(1),was designed and prepared.Free 1 mainly displayed very weak fluorescence at 480 nm upone xcitation at 403 nln.It displayed high selectivity for Zn2+ and had a 518-fold fluorescent enhancement upon binding of Zn2+.while the other cation ions had only little influence on the fluorescence of 1.Mechanism of enhancement of 1's fluorescence by Zn2+ was briefly discussed.

  4. Highly sensitive bolometers for rare alpha decay studies

    Directory of Open Access Journals (Sweden)

    Gironi L.

    2014-03-01

    Full Text Available High resolution detectors able to identify background events are very appealing in the study of rare nuclear processes. Scintillating bolometers featuring simultaneous read-out of heat and scintillation signals, can effectively address this problem thanks to the possibility to discriminate different ionizing particles and achieve background free experiments. With this technique it has already been possible to measure rare alpha decays never observed before or improve by orders of magnitude the existing limits.

  5. Solar neutrino measurements in Super-Kamiokande-I

    CERN Document Server

    Hosaka, J; Kameda, J; Koshio, Y; Minamino, A; Mitsuda, C; Miura, M; Moriyama, S; Nakahata, M; Namba, T; Obayashi, Y; Sakurai, N; Sarrat, A; Shiozawa, M; Suzuki, Y; Takeuchi, Y; Yamada, S; Higuchi, I; Ishitsuka, M; Kajita, T; Kaneyuki, K; Mitsuka, G; Nakayama, S; Nishino, H; Okada, A; Okumura, K; Saji, C; Takenaga, Y; Clark, S; Desai, S; Kearns, E; Likhoded, S; Stone, J L; Sulak, L R; Wang, W; Goldhaber, M; Casper, D; Cravens, J P; Kropp, W R; Liu, D W; Mine, S; Smy, M B; Sobel, H W; Sterner, C W; Vagins, M R; Ganezer, K S; Hill, J; Keig, W E; Jang, J S; Kim, J Y; Lim, I T; Scholberg, K; Walter, C W; Ellsworth, R W; Tasaka, S; Guillian, G; Kibayashi, A; Learned, J G; Matsuno, S; Messier, M D; Hayato, Y; Ichikawa, A K; Ishida, T; Ishii, T; Iwashita, T; Kobayashi, T; Nakadaira, T; Nakamura, K; Nitta, K; Oyama, Y; Totsuka, Y; Suzuki, A T; Hasegawa, M; Kato, I; Maesaka, H; Nakaya, T; Nishikawa, K; Sasaki, T; Sato, H; Yamamoto, S; Yokoyama, M; Haines, T J; Dazeley, S; Kim, B K; Lee, K B; Hatakeyama, S; Svoboda, R; Blaufuss, E; Goodman, J A; Sullivan, G W; Turcan, D; Cooley, J; Habig, A; Fukuda, Y; Sato, T; Itow, Y; Jung, C K; Kato, T; Kobayashi, K; Malek, M; Martens, K; Mauger, C; McGrew, C; Sharkey, E; Yanagisawa, C; Tamura, N; Sakuda, M; Kuno, Y; Yoshida, M; Kim, S B; Yoo, J; Okazawa, H; Ishizuka, T; Choi, Y; Seo, H K; Gando, Y; Hasegawa, T; Inoue, K; Shirai, J; Suzuki, A; Nishijima, K; Ishino, H; Watanabe, Y; Koshiba, M; Kielczewska, D; Zalipska, J; Berns, H G; Gran, R; Shiraishi, K K; Stachyra, A L; Washburn, K; Wilkes, R J

    2006-01-01

    The details of Super--Kamiokande--I's solar neutrino analysis are given. Solar neutrino measurement in Super--Kamiokande is a high statistics collection of $^8$B solar neutrinos via neutrino-electron scattering. The analysis method and results of the 1496 day data sample are presented. The final oscillation results for the data are also presented.

  6. Laboratory Earthquake Measurements with the High-speed Digital Image Correlation Method and Applications to Super-shear Transition

    Science.gov (United States)

    Rubino, V.; Lapusta, N.; Rosakis, A.

    2012-12-01

    Mapping full-field displacements and strains on the Earth's surface during an earthquake is of paramount importance to enhance our understanding of earthquake mechanics. In this study, the feasibility of such measurements using image correlation methods is investigated in a laboratory earthquake setup. Earthquakes are mimicked in the laboratory by dynamic rupture propagating along an inclined frictional interface formed by two Homalite plates under compression, using the configuration developed by Rosakis and coworkers (e.g., Rosakis et al., 2007). In our study, the interface is partially glued, in order to confine the rupture before it reaches the ends of the specimen. The specimens are painted with a speckle pattern to provide the surface with characteristic features for image matching. Images of the specimens are taken before and after dynamic rupture with a 4 Megapixels resolution CCD camera. The digital images are analyzed with two software packages: VIC-2D (Correlated Solutions Inc.) and COSI-Corr (Leprince et. al, 2007). Both VIC-2D and COSI-Corr are able to characterize the full-field static displacement of a dynamic crack. For example, in a case with secondary mode I cracks, the correlation analysis performed with either software clearly shows (i) the relative displacement (slip) along the frictional interface, (ii) the rupture arrest on the glued boundaries, and (iii) the presence of two wing cracks. The obtained displacement measurements are converted to strains, using de-noising techniques. The digital image correlation method is then used in combination with high-speed photography. We will report our progress on the study of a spontaneously expanding sub-Rayleigh shear crack advancing along an interface containing a patch of favorable heterogeneity, such as a preexisting subcritical crack or a patch with higher prestress. According to the predictions of Liu and Lapusta (2008), intersonic transition and propagation can be achieved in the presence of a

  7. Aptamer-Functionalized Fluorescent Silica Nanoparticles for Highly Sensitive Detection of Leukemia Cells

    Science.gov (United States)

    Tan, Juntao; Yang, Nuo; Hu, Zixi; Su, Jing; Zhong, Jianhong; Yang, Yang; Yu, Yating; Zhu, Jianmeng; Xue, Dabin; Huang, Yingying; Lai, Zongqiang; Huang, Yong; Lu, Xiaoling; Zhao, Yongxiang

    2016-06-01

    A simple, highly sensitive method to detect leukemia cells has been developed based on aptamer-modified fluorescent silica nanoparticles (FSNPs). In this strategy, the amine-labeled Sgc8 aptamer was conjugated to carboxyl-modified FSNPs via amide coupling between amino and carboxyl groups. Sensitivity and specificity of Sgc8-FSNPs were assessed using flow cytometry and fluorescence microscopy. These results showed that Sgc8-FSNPs detected leukemia cells with high sensitivity and specificity. Aptamer-modified FSNPs hold promise for sensitive and specific detection of leukemia cells. Changing the aptamer may allow the FSNPs to detect other types of cancer cells.

  8. Highly sensitive passive radio frequency identification based sensor systems.

    Science.gov (United States)

    Wissenwasser, J; Vellekoop, M; Heer, R

    2010-02-01

    A novel platform for sensor applications based on radio frequency (rf) identification technology, where passive tags are powered by the rf-field of a reader, is presented. The sophisticated energy harvesting system of the tag enables a blanking of the rf-field for a defined period, while supplying the tag electronics with a highly stable voltage and a power of 25 mW for 100 ms. During this time, span measurements can be performed without interferences of the rf-field. The presented tags work without batteries and are designed for impedance measurements on microbiological cell cultures under physiological relevant conditions as well as in harsh environments.

  9. Highly sensitive passive radio frequency identification based sensor systems

    Science.gov (United States)

    Wissenwasser, J.; Vellekoop, M.; Heer, R.

    2010-02-01

    A novel platform for sensor applications based on radio frequency (rf) identification technology, where passive tags are powered by the rf-field of a reader, is presented. The sophisticated energy harvesting system of the tag enables a blanking of the rf-field for a defined period, while supplying the tag electronics with a highly stable voltage and a power of 25 mW for 100 ms. During this time, span measurements can be performed without interferences of the rf-field. The presented tags work without batteries and are designed for impedance measurements on microbiological cell cultures under physiological relevant conditions as well as in harsh environments.

  10. Purification of ethanol for highly sensitive self-assembly experiments

    Directory of Open Access Journals (Sweden)

    Kathrin Barbe

    2014-08-01

    Full Text Available Ethanol is the preferred solvent for the formation of self-assembled monolayers (SAMs of thiolates on gold. By applying a thin film sensor system, we could demonstrate that even the best commercial qualities of ethanol contain surface-active contaminants, which can compete with the desired thiolates for surface sites. Here we present that gold nanoparticles deposited onto zeolite X can be used to remove these contaminants by chemisorption. This nanoparticle-impregnated zeolite does not only show high capacities for surface-active contaminants, such as thiols, but can be fully regenerated via a simple pyrolysis protocol.

  11. Dynamics and sensitivity analysis of high-frequency conduction block

    Science.gov (United States)

    Ackermann, D. Michael; Bhadra, Niloy; Gerges, Meana; Thomas, Peter J.

    2011-10-01

    The local delivery of extracellular high-frequency stimulation (HFS) has been shown to be a fast acting and quickly reversible method of blocking neural conduction and is currently being pursued for several clinical indications. However, the mechanism for this type of nerve block remains unclear. In this study, we investigate two hypotheses: (1) depolarizing currents promote conduction block via inactivation of sodium channels and (2) the gating dynamics of the fast sodium channel are the primary determinate of minimal blocking frequency. Hypothesis 1 was investigated using a combined modeling and experimental study to investigate the effect of depolarizing and hyperpolarizing currents on high-frequency block. The results of the modeling study show that both depolarizing and hyperpolarizing currents play an important role in conduction block and that the conductance to each of three ionic currents increases relative to resting values during HFS. However, depolarizing currents were found to promote the blocking effect, and hyperpolarizing currents were found to diminish the blocking effect. Inward sodium currents were larger than the sum of the outward currents, resulting in a net depolarization of the nodal membrane. Our experimental results support these findings and closely match results from the equivalent modeling scenario: intra-peritoneal administration of the persistent sodium channel blocker ranolazine resulted in an increase in the amplitude of HFS required to produce conduction block in rats, confirming that depolarizing currents promote the conduction block phenomenon. Hypothesis 2 was investigated using a spectral analysis of the channel gating variables in a single-fiber axon model. The results of this study suggested a relationship between the dynamical properties of specific ion channel gating elements and the contributions of corresponding conductances to block onset. Specifically, we show that the dynamics of the fast sodium inactivation gate are

  12. The SuperNova Early Warning System

    OpenAIRE

    Scholberg, K.

    2008-01-01

    A core collapse in the Milky Way will produce an enormous burst of neutrinos in detectors world-wide. Such a burst has the potential to provide an early warning of a supernova's appearance. I will describe the nature of the signal, the sensitivity of current detectors, and SNEWS, the SuperNova Early Warning System, a network designed to alert astronomers as soon as possible after the detected neutrino signal.

  13. A compact high-sensitivity heterodyne interferometer for industrial metrology

    Science.gov (United States)

    Schuldt, Thilo; Gohlke, Martin; Weise, Dennis; Peters, Achim; Johann, Ulrich; Braxmaier, Claus

    2008-04-01

    For translation and tilt metrology, we developed a compact fiber-coupled polarizing heterodyne interferometer which is based on a highly symmetric design where both, measurement and reference beam have similar optical pathlengths and the same frequency and polarization. The method of differential wavefront sensing is implemented for tilt measurement. With this setup we reached noise levels below 5 pm/square root of Hz; Hz in translation and below 10 nrad/square root of Hz; in tilt measurement, both for frequencies above 10-2 Hz. While this setup is developed with respect to the requirements of the LISA (Laser Interferometer Space Antenna) space mission, we here present the current status of its adoption to industrial applications. We currently design a very compact and quasi-monolithic setup of the interferometer sensor head based on ultra-low expansion glass material. The resulting compact and robust sensor head can be used for nano-positioning control. We also plan to implement a scan of the measurement beam over the surface under investigation enabling high resolution 3D profilometry and surface property measurements (i. e. roughness, evenness and roundness). The dedicated low-noise (piezo-electric actuator in the measurement beam of the interferometer will be realized using integrated micro-system technology and can either be implemented in one or two dimensions.

  14. Highly sensitive thermoluminescent carbon doped nanoporous aluminium oxide detectors.

    Science.gov (United States)

    de Azevedo, W M; de Oliveira, G B; da Silva, E F; Khoury, H J; Oliveira de Jesus, E F

    2006-01-01

    In this work we present the synthesis, characterisation and the thermoluminescence (TL) response of nanoporous carbon doped aluminium oxide Al2O3:C produced by anodic oxidation of aluminium in organic and inorganic solvents. The X-ray and scanning electron microscopy (SEM) measurements reveal that the synthesised samples are amorphous and present highly ordered structures with uniform pore distribution with diameter of the order 50 nm. The photoluminescence and spectroscopic analysis in the visible and infrared regions show that the luminescence properties presented by the samples prepared in organic acid are due to carboxylate species, incorporated in anodic alumina films during the synthesis process. After an annealing treatment, part of the incorporated species decomposes and is incorporated into the structure of the aluminium oxide yielding a highly thermoluminescent detector (TL) . The results for X-ray irradiation in the range from 21 to 80 keV indicate a linear TL response with the dose in the range from 5 mGy to 1 Gy, suggesting that nanoporous aluminium oxide produced in the present route of synthesis is a suitable detector for radiation measurements.

  15. Porous tungsten oxide nanoflakes for highly alcohol sensitive performance.

    Science.gov (United States)

    Xiao, J; Liu, P; Liang, Y; Li, H B; Yang, G W

    2012-11-21

    Porous tungsten oxide (WO(3)) nanoflakes have been synthesized by a simple and green approach in an ambient environment. As a precursor solution a polycrystalline hydrated tungstite (H(2)WO(4)·H(2)O) nanoparticles colloid was first prepared by pulsed-laser ablation of a tungsten target in water. The H(2)WO(4)·H(2)O nanoflakes were produced by 72 h aging treatment at room temperature. Finally, porous WO(3) nanoflakes were synthesized by annealing at 800 °C for 4 h. Considering the large surface-to-volume ratio of porous nanoflakes, a porous WO(3) nanoflake gas sensor was fabricated, which exhibits an excellent sensor response performance to alcohol concentrations in the range of 20 to 600 ppm under low working temperature. This high response was attributed to the highly crystalline and porous flake-like morphology, which leads to effective adsorption and desorption, and provides more active sites for the gas molecules' reaction. These findings showed that the porous tungsten oxide nanoflake has great potential in gas-sensing performance.

  16. Highly sensitive temperature sensor based on an isopropanol-filled photonic crystal fiber long period grating

    Science.gov (United States)

    Du, Chao; Wang, Qi; Zhao, Yong; Li, Jin

    2017-03-01

    A high sensitivity measurement method for temperature has been proposed and investigated based on an isopropanol-filled photonic crystal fiber long period grating (PCF-LPG). Due to the high thermo-optic coefficient (TOC) of isopropanol, the sensitivity of the proposed temperature sensor could be effectively improved by filling isopropanol in the air waveguides of PCF. It can be found that the resonant dip will be split in two dips after filling isopropanol and the two dips have different sensitivities to surrounding temperature. Because of PCF-LPG is sensitive to the refractive index (RI) of internal filled liquid, the isopropanol-filled PCF-LPG temperature sensor has a high sensitivities of 1.356 nm/°C in the range of 20-50 °C. The simplicity and the excellent performance of our proposed device make it potential for the applications of high-precision temperature measurement is required.

  17. A novel high resolution, high sensitivity SPECT detector for molecular imaging of cardiovascular diseases

    Science.gov (United States)

    Cusanno, F.; Argentieri, A.; Baiocchi, M.; Colilli, S.; Cisbani, E.; De Vincentis, G.; Fratoni, R.; Garibaldi, F.; Giuliani, F.; Gricia, M.; Lucentini, M.; Magliozzi, M. L.; Majewski, S.; Marano, G.; Musico, P.; Musumeci, M.; Santavenere, F.; Torrioli, S.; Tsui, B. M. W.; Vitelli, L.; Wang, Y.

    2010-05-01

    Cardiovascular diseases are the most common cause of death in western countries. Understanding the rupture of vulnerable atherosclerotic plaques and monitoring the effect of innovative therapies of heart failure is of fundamental importance. A flexible, high resolution, high sensitivity detector system for molecular imaging with radionuclides on small animal models has been designed for this aim. A prototype has been built using tungsten pinhole and LaBr3(Ce) scintillator coupled to Hamamatsu Flat Panel PMTs. Compact individual-channel readout has been designed, built and tested. Measurements with phantoms as well as pilot studies on mice have been performed, the results show that the myocardial perfusion in mice can be determined with sufficient precision. The detector will be improved replacing the Hamamatsu Flat Panel with Silicon Photomultipliers (SiPMs) to allow integration of the system with MRI scanners. Application of LaBr3(Ce) scintillator coupled to photosensor with high photon detection efficiency and excellent energy resolution will allow dual-label imaging to monitor simultaneously the cardiac perfusion and the molecular targets under investigation during the heart therapy.

  18. Color Sensitivity Multiple Exposure Fusion using High Dynamic Range Image

    Directory of Open Access Journals (Sweden)

    Varsha Borole

    2014-02-01

    Full Text Available In this paper, we present a high dynamic range imaging (HDRI method using a capturing camera image using normally exposure, over exposure and under exposure. We make three different images from a multiple input image using local histogram stretching. Because the proposed method generated three histogram-stretched images from a multiple input image, ghost artifacts that are the result of the relative motion between the camera and objects during exposure time, are inherently removed. Therefore, the proposed method can be applied to a consumer compact camera to provide the ghost artifacts free HDRI. Experiments with several sets of test images with different exposures show that the proposed method gives a better performance than existing methods in terms of visual results and computation time.

  19. High sensitivity, wide coverage, and high-resolution NIR non-cryogenic spectrograph, WINERED

    Science.gov (United States)

    Ikeda, Yuji; Kobayashi, Naoto; Kondo, Sohei; Otsubo, Shogo; Hamano, Satoshi; Sameshima, Hiroaki; Yoshikawa, Tomoshiro; Fukue, Kei; Nakanishi, Kenshi; Kawanishi, Takafumi; Nakaoka, Tetsuya; Kinoshita, Masaomi; Kitano, Ayaka; Asano, Akira; Takenaka, Keiichi; Watase, Ayaka; Mito, Hiroyuki; Yasui, Chikako; Minami, Atsushi; Izumu, Natsuko; Yamamoto, Ryo; Mizumoto, Misaki; Arasaki, Takayuki; Arai, Akira; Matsunaga, Noriyuki; Kawakita, Hideyo

    2016-08-01

    Near-infrared (NIR) high-resolution spectroscopy is a fundamental observational method in astronomy. It provides significant information on the kinematics, the magnetic fields, and the chemical abundances, of astronomical objects embedded in or behind the highly extinctive clouds or at the cosmological distances. Scientific requirements have accelerated the development of the technology required for NIR high resolution spectrographs using 10 m telescopes. WINERED is a near-infrared (NIR) high-resolution spectrograph that is currently mounted on the 1.3 m Araki telescope of the Koyama Astronomical Observatory in Kyoto-Sangyo University, Japan, and has been successfully operated for three years. It covers a wide wavelength range from 0.90 to 1.35 μm (the z-, Y-, and J-bands) with a spectral resolution of R = 28,000 (Wide-mode) and R = 80,000 (Hires-Y and Hires-J modes). WINERED has three distinctive features: (i) optics with no cold stop, (ii) wide spectral coverage, and (iii) high sensitivity. The first feature, originating from the Joyce proposal, was first achieved by WINERED, with a short cutoff infrared array, cold baffles, and custom-made thermal blocking filters, and resulted in reducing the time for development, alignment, and maintenance, as well as the total cost. The second feature is realized with the spectral coverage of Δλ/λ 1/6 in a single exposure. This wide coverage is realized by a combination of a decent optical design with a cross-dispersed echelle and a large format array (2k x 2k HAWAII- 2RG). The Third feature, high sensitivity, is achieved via the high-throughput optics (>60 %) and the very low noise of the system. The major factors affecting the high throughput are the echelle grating and the VPH cross-disperser with high diffraction efficiencies of 83 % and 86 %, respectively, and the high QE of HAWAII-2RG (83 % at 1.23 μm). The readout noise of the electronics and the ambient thermal background radiation at longer wavelengths could be

  20. Effects of intrinsic magnetostriction on tube-topology magnetoelectric sensors with high magnetic field sensitivity

    Science.gov (United States)

    Gillette, Scott M.; Fitchorov, Trifon; Obi, Ogheneyunume; Jiang, Liping; Hao, Hongbo; Wu, Shuangxia; Chen, Yajie; Harris, Vincent G.

    2014-05-01

    Three quasi-one-dimensional magnetoelectric (ME) magnetic field sensors, each with a different magnetostrictive wire material, were investigated in terms of sensitivity and noise floor. Magnetostrictive Galfenol, iron-cobalt-vanadium, and iron-nickel wires were examined. Sensitivity profiles, hysteresis effects, and noise floor measurements for both optimally biased and zero-biased conditions are presented. The FeNi wire (FN) exhibits high sensitivity (5.36 mV/Oe) at bias fields below 22 Oe and an optimal bias of 10 Oe, whereas FeGa wire (FG) exhibits higher sensitivity (6.89 mW/Oe) at bias fields >22 Oe. The sensor of FeCoV wire (FC) presents relatively low sensitivity (2.12 mV/Oe), due to low magnetostrictive coefficient. Each ME tube-topology sensor demonstrates relatively high sensitivity at zero bias field, which results from a magnetic shape anisotropy and internal strain of the thin magnetostrictive wire.

  1. Nanowire-templated microelectrodes for high-sensitivity pH detection

    DEFF Research Database (Denmark)

    Antohe, V.A.; Radu, Adrian; Mátéfi-Tempfli, Mária

    2009-01-01

    A highly sensitive pH capacitive sensor has been designed by confined growth of vertically aligned nanowire arrays on interdigited microelectrodes. The active surface of the device has been functionalized with an electrochemical pH transducer (polyaniline). We easily tune the device features...... by combining lithographic techniques with electrochemical synthesis. The reported electrical LC resonance measurements show considerable sensitivity enhancement compared to conventional capacitive pH sensors realized with microfabricated interdigited electrodes. The sensitivity can be easily improved...

  2. Super SI燃烧方式试验研究%Super SI Combustion Mode

    Institute of Scientific and Technical Information of China (English)

    沈义涛; 吕世亮; 尹琪; 杨嘉林; 高卫民

    2011-01-01

    The super spark ignition (Super SI) combustion mode, which was the ignition combustion of lean mixture at the temperature of close spontaneous combustion, was researched and its combustion characteristic and feasibility were analyzed.The results indicate that the increase of intake temperature can reduce the cyclic variation of Pmi obviously, shorten the combustion duration and extend the lean limit of SI combustion under the condition of lean mixture. Accordingly, Super SI combustion has the advantages of high thermal efficiency and controllable combustion process.%研究了Super Spark Ignition(Super SI)燃烧方式,即稀薄混合气在近自燃温度状态下点燃燃烧,分析了这种燃烧方式的可行性和燃烧特性.研究结果表明,混合气稀薄时提高发动机的进气温度可显著降低平均指示压力(pmi)的循环波动,缩短燃烧持续期,拓展点燃燃烧的稀薄极限;Super SI燃烧方式具有热效率高、燃烧过程可控的优点.

  3. KML Super Overlay to WMS Translator

    Science.gov (United States)

    Plesea, Lucian

    2007-01-01

    This translator is a server-based application that automatically generates KML super overlay configuration files required by Google Earth for map data access via the Open Geospatial Consortium WMS (Web Map Service) standard. The translator uses a set of URL parameters that mirror the WMS parameters as much as possible, and it also can generate a super overlay subdivision of any given area that is only loaded when needed, enabling very large areas of coverage at very high resolutions. It can make almost any dataset available as a WMS service visible and usable in any KML application, without the need to reformat the data.

  4. Super resolution of images and video

    CERN Document Server

    Katsaggelos, Aggelos K

    2007-01-01

    This book focuses on the super resolution of images and video. The authors' use of the term super resolution (SR) is used to describe the process of obtaining a high resolution (HR) image, or a sequence of HR images, from a set of low resolution (LR) observations. This process has also been referred to in the literature as resolution enhancement (RE). SR has been applied primarily to spatial and temporal RE, but also to hyperspectral image enhancement. This book concentrates on motion based spatial RE, although the authors also describe motion free and hyperspectral image SR problems. Also exa

  5. Hypoxia-sensitive reporter system for high-throughput screening.

    Science.gov (United States)

    Tsujita, Tadayuki; Kawaguchi, Shin-ichi; Dan, Takashi; Baird, Liam; Miyata, Toshio; Yamamoto, Masayuki

    2015-01-01

    The induction of anti-hypoxic stress enzymes and proteins has the potential to be a potent therapeutic strategy to prevent the progression of ischemic heart, kidney or brain diseases. To realize this idea, small chemical compounds, which mimic hypoxic conditions by activating the PHD-HIF-α system, have been developed. However, to date, none of these compounds were identified by monitoring the transcriptional activation of hypoxia-inducible factors (HIFs). Thus, to facilitate the discovery of potent inducers of HIF-α, we have developed an effective high-throughput screening (HTS) system to directly monitor the output of HIF-α transcription. We generated a HIF-α-dependent reporter system that responds to hypoxic stimuli in a concentration- and time-dependent manner. This system was developed through multiple optimization steps, resulting in the generation of a construct that consists of the secretion-type luciferase gene (Metridia luciferase, MLuc) under the transcriptional regulation of an enhancer containing 7 copies of 40-bp hypoxia responsive element (HRE) upstream of a mini-TATA promoter. This construct was stably integrated into the human neuroblastoma cell line, SK-N-BE(2)c, to generate a reporter system, named SKN:HRE-MLuc. To improve this system and to increase its suitability for the HTS platform, we incorporated the next generation luciferase, Nano luciferase (NLuc), whose longer half-life provides us with flexibility for the use of this reporter. We thus generated a stably transformed clone with NLuc, named SKN:HRE-NLuc, and found that it showed significantly improved reporter activity compared to SKN:HRE-MLuc. In this study, we have successfully developed the SKN:HRE-NLuc screening system as an efficient platform for future HTS.

  6. SLAP: Small Labeling Pair for Single-Molecule Super-Resolution Imaging.

    Science.gov (United States)

    Wieneke, Ralph; Raulf, Anika; Kollmannsperger, Alina; Heilemann, Mike; Tampé, Robert

    2015-08-24

    Protein labeling with synthetic fluorescent probes is a key technology in chemical biology and biomedical research. A sensitive and efficient modular labeling approach (SLAP) was developed on the basis of a synthetic small-molecule recognition unit (Ni-trisNTA) and the genetically encoded minimal protein His6-10 -tag. High-density protein tracing by SLAP was demonstrated. This technique allows super-resolution fluorescence imaging and fulfills the necessary sampling criteria for single-molecule localization-based imaging techniques. It avoids masking by large probes, for example, antibodies, and supplies sensitive, precise, and robust size analysis of protein clusters (nanodomains).

  7. Breeding of High Quality and Super Early Maturing Hybird Maize Qiangsheng 3%高产紧凑极早熟玉米杂交种强盛3号的选育

    Institute of Scientific and Technical Information of China (English)

    王华; 刘虹; 武岩军; 尚春树

    2012-01-01

    Qiangsheng 3 was a super early maturing maize hybrid selected from the crossing of two inbred lines, with female parent PS3 and male parent 141-038, by Shanxi Qiangsheng Seeds Co. Ltd. in 2006. It showed many improved traits like high yielding, disease and lodging resistance, super early maturing, etc. in super early maturing maize area production experiment in 2008-2010, thus it bears good practical values in field production. Qiangsheng 3 was authorized by Crop Variety Authorization Committee of Shanxi in 2012.%强盛3号是由山西强盛种业有限公司玉米育种部于2006年以自选系PS3为母本、141-038为父本杂交选育而成的极早熟玉米杂交种.该品种于2008-2010年参加山西省极早熟玉米区域试验和生产试验,表现出高产、抗病、紧凑、极早熟等特点,在生产上具有较高的推广应用价值.2012年通过山西省农作物品种审定委员会审定.

  8. Sensory Processing Sensitivity: Factors of the Highly Sensitive Person Scale and Their relationships to Personality and Subjective Health Complaints.

    Science.gov (United States)

    Listou Grimen, Hanne; Diseth, Åge

    2016-12-01

    The aim of the present study was to examine the factor structure of a Norwegian version of the Highly Sensitive Person Scale (HSPS) and to investigate how sensory processing sensitivity (SPS) is related to personality traits of neuroticism, extraversion, and openness and to subjective health complaints (SHC) in a sample of 167 undergraduate psychology students. The results showed that the variance in a shortened version of the HSPS was best described by three separate factors: ease of excitation (EOE), aesthetic sensitivity (AES), and low sensory threshold (LST). Furthermore, the result showed than an overall SPS factor (EOE, LST, and AES combined) was predicted positively by neuroticism and openness and negatively by extraversion. With respect to SHC, the results showed that EOE and LST were positively associated with psychological health complaints. However, the personality trait of neuroticism contributed more than the SPS factors as predictor of SHC. In conclusion, the present study supported a shortened version of the HSPS and its relation to personality factors and SHC.

  9. Enhanced laboratory sensitivity to variation of the fine-structure constant using highly charged ions.

    Science.gov (United States)

    Berengut, J C; Dzuba, V A; Flambaum, V V

    2010-09-17

    We study atomic systems that are in the frequency range of optical atomic clocks and have enhanced sensitivity to potential time variation of the fine-structure constant α. The high sensitivity is due to coherent contributions from three factors: high nuclear charge Z, high ionization degree, and significant differences in the configuration composition of the states involved. Configuration crossing keeps the frequencies in the optical range despite the large ionization energies. We discuss a few promising examples that have the largest α sensitivities seen in atomic systems.

  10. High Sensitivity 1-D and 2-D Microwave Spectroscopy via Cryogenic Buffer Gas Cooling

    Science.gov (United States)

    Patterson, David; Eibenberger, Sandra

    2017-06-01

    All rotationally resolved spectroscopic methods rely on sources of cold molecules. For the last three decades, the workhorse technique for producing highly supersaturated samples of cold molecules has been the pulsed supersonic jet. We present here progress on our alternative method, cryogenic buffer gas cooling. Our high density, continuous source, and low noise temperature allow us to record microwave spectra at unprecedented sensitivity, with a dynamic range in excess of 10^6 achievable in a few minutes of integration time. This high sensitivity enables new protocols in both 1-D and 2-D microwave spectroscopy, including sensitive chiral analysis via nonlinear three wave mixing and applications as an analytical chemistry tool

  11. Highly sensitive surface plasmon resonance chemical sensor based on Goos-Hanchen effects

    Science.gov (United States)

    Yin, Xiaobo; Hesselink, Lambertus

    2006-08-01

    The resonance enhanced Goos-Hanchen shifts at attenuated total internal reflection enables the possibility for highly sensitive surface plasmon resonance sensor. The observed giant displacements result from the singular phase retardation at the resonance where the phase is continuous but changes dramatically. The phenomenon is proposed for chemical sensing and the superior sensitivity is demonstrated.

  12. 某超高速转子系统减振结构研究%Research on vibration absorber for a super-high speed rotor system

    Institute of Scientific and Technical Information of China (English)

    陈巍; 杜发荣; 丁水汀; 韩树军; 李云清

    2011-01-01

    为解决某超高速转子系统的失稳碰摩问题,以干摩擦阻尼耗散转子涡动能量理论为依据,采用一种自由安装式干摩擦片减振结构(干摩擦阻尼器).该结构在转轴上安装波形弹性垫片及干摩擦片,通过螺母预紧力矩向波形弹性垫片及各干摩擦片提供轴向正压力.干摩擦片随转子振动并产生相对运动,从而耗散转子涡动能量,达到减振、增强转子稳定性的目的.通过实验不同数量的干摩擦片和不同预紧力矩的组合寻找满足工程稳定性的减振器结构参数.结果表明:干摩擦阻尼器适用于高速、轻载转子系统的减振、增稳,可以有效降低转子振动,控制转子涡动发散的趋势;所用实验方法有助于快速获得满足工程稳定性的减振结构参数.%A kind of freely assembled dry friction vibration absorber was presented to solve the problems of instability and rubbing faults for a super-high speed rotor system based on theory of dry friction dissipating energy from rotor vibration. In this structure, a waveshaped elastic pad and some dry friction pads were freely assembled on shaft, and axial normai force was provided for elastic pad and dry friction pads by pre-loaded moment for nut.When friction pads moved with shaft, the relative movements between them could dissipate vibration energy from rotor system, absorb vibration and enhance system stability. The configuration format meeting the stability in engineering for the damper of the studied rotor system has been acquired by testing different groups of dry friction pads and pre-loaded moment. The results show that dry friction damper is suitable for high speed and light loaded rotor system to restrain vibration and enhance its stability. The testing routine is helpful to find a comfortable configuration format in engineering of dry friction damper.

  13. Single Image Super Resolution via Sparse Reconstruction

    NARCIS (Netherlands)

    Kruithof, M.C.; Eekeren, A.W.M. van; Dijk, J.; Schutte, K.

    2012-01-01

    High resolution sensors are required for recognition purposes. Low resolution sensors, however, are still widely used. Software can be used to increase the resolution of such sensors. One way of increasing the resolution of the images produced is using multi-frame super resolution algorithms. Limita

  14. Typhoon effects on super-tall buildings

    Science.gov (United States)

    Li, Q. S.; Xiao, Y. Q.; Wu, J. R.; Fu, J. Y.; Li, Z. N.

    2008-06-01

    Full-scale measurement is considered to be the most reliable method for evaluating wind effects on buildings and structures. This paper presents selected results of wind characteristics and structural responses measured from four super-tall buildings, The Center (350 m high, 79 floors) in Hong Kong, Di Wang Tower (384 m high, 78 floors) in Shenzhen, CITIC Plaza Tower (391 m high, 80 floors) in Guangzhou and Jin Mao Building (421 m high, 88 floors) in Shanghai, during the passages of three typhoons. The field data such as wind speed, wind direction and acceleration responses, etc., were continuously measured from the super-tall buildings during the typhoons. Detailed analysis of the field data was conducted to investigate the characteristics of typhoon-generated wind and wind-induced vibrations of these super-tall buildings under typhoon conditions. The dynamic characteristics of the tall buildings were determined from the field measurements and comparisons with those calculated from the finite element (FE) models of the structures were made. Furthermore, the full-scale measurements were compared with wind tunnel results to evaluate the accuracy of the model test results and the adequacy of the techniques used in the wind tunnel tests. The results presented in this paper are expected to be of considerable interest and of use to researchers and professionals involved in designing super-tall buildings.

  15. NASA Super Pressure Balloon

    Science.gov (United States)

    Fairbrother, Debbie

    2017-01-01

    NASA is in the process of qualifying the mid-size Super Pressure Balloon (SPB) to provide constant density altitude flight for science investigations at polar and mid-latitudes. The status of the development of the 18.8 million cubic foot SPB capable of carrying one-tone of science to 110,000 feet, will be given. In addition, the operating considerations such as launch sites, flight safety considerations, and recovery will be discussed.

  16. Super-diversité

    NARCIS (Netherlands)

    Crul, M.R.J.; Schneider, J.; Lelie, F.

    2013-01-01

    Le concept de super-diversité, en cernant les conditions d'un scénario 'avenir optimiste, offre un nouvel éclairage au débat sur l'intégration. Nous sommes à la croisée des chemins. Cette étude comparative internationale montre qu'un avenir souriant se profile dans les villes qui donnent des chances

  17. Performing the Super Instrument

    DEFF Research Database (Denmark)

    Kallionpaa, Maria

    2016-01-01

    The genre of contemporary classical music has seen significant innovation and research related to new super, hyper, and hybrid instruments, which opens up a vast palette of expressive potential. An increasing number of composers, performers, instrument designers, engineers, and computer programmers...... provides the performer extensive virtuoso capabilities in terms of instrumental range, harmony, timbre, or spatial, textural, acoustic, technical, or technological qualities. The discussion will be illustrated by a composition case study involving augmented musical instrument electromagnetic resonator...

  18. Performing the Super Instrument

    DEFF Research Database (Denmark)

    Kallionpaa, Maria

    2016-01-01

    provides the performer extensive virtuoso capabilities in terms of instrumental range, harmony, timbre, or spatial, textural, acoustic, technical, or technological qualities. The discussion will be illustrated by a composition case study involving augmented musical instrument electromagnetic resonator......The genre of contemporary classical music has seen significant innovation and research related to new super, hyper, and hybrid instruments, which opens up a vast palette of expressive potential. An increasing number of composers, performers, instrument designers, engineers, and computer programmers...

  19. Long term salinity stress in relation to lipid peroxidation, super oxide dismutase activity and proline content of salt-sensitive and salt-tolerant wheat cultivars Estrés salino a largo plazo en relación con peroxidación lipídica, actividad superóxido dismutasa y contenido de prolina de cultivares de trigo sensibles y tolerantes a la salinidad

    Directory of Open Access Journals (Sweden)

    Azam Borzouei

    2012-12-01

    Full Text Available Salinity is a widespread root medium problem limiting productivity of cereal crops worldwide. The ability of plants to tolerate salt is determined by multiple biochemical pathways that facilitate retention and/or acquisition of water, protect chloroplast functions, and maintain ion homeostasis. Therefore, the ability of salt-sensitive ('Tajan' and salt-tolerant cultivar ('Bam' of Triticum aestivum L. to adapt to a saline environment were evaluated in a set of greenhouse experiments under salt stress during three growth stages (tillering, 50% anthesis, and 10 d after anthesis. Plants were irrigated by different saline waters with electrical conductivities of 1.3, 6, 8, 10, and 12 dS m-1, which were obtained by adding NaCl:CaCl2 in 10:1 molar ratio to fresh water. Differences in growth parameters, lipid peroxidation, superoxide dismutase (SOD activity, and proline accumulation were tested in order to put forward the relative tolerance or sensitivity of cultivars. Results indicated that both parameters differ according to the cultivar's ability in coping oxidative stress caused by salinity. We observed a greater decline in the growth parameters and grain yield under salt stress in 'Tajan' than in 'Bam'. Malondialdehyde content was also higher in 'Tajan'. The improved performance of the 'Bam' under high salinity was accompanied by an increase in SOD (EC 1.15.1.1 activity and proline content at all growth stages. Growth parameters, lipid peroxidation and proline accumulation results are also in good correlation with supporting this cultivar is being relatively tolerant.La salinidad es un problema del medio radical ampliamente distribuido que limita la productividad de los cultivos de cereal en todo el mundo. La capacidad de las plantas para tolerar la sal está determinada por multiples vías bioquímicas que facilitan la retención y/o adquisición de agua, protegen las funciones del cloroplasto, y mantienen la homeostasis iónica. Por lo tanto, se

  20. Super-quantum curves from super-eigenvalue models

    CERN Document Server

    Ciosmak, Paweł; Manabe, Masahide; Sułkowski, Piotr

    2016-01-01

    In modern mathematical and theoretical physics various generalizations, in particular supersymmetric or quantum, of Riemann surfaces and complex algebraic curves play a prominent role. We show that such supersymmetric and quantum generalizations can be combined together, and construct supersymmetric quantum curves, or super-quantum curves for short. Our analysis is conducted in the formalism of super-eigenvalue models: we introduce $\\beta$-deformed version of those models, and derive differential equations for associated $\\alpha/\\beta$-deformed super-matrix integrals. We show that for a given model there exists an infinite number of such differential equations, which we identify as super-quantum curves, and which are in one-to-one correspondence with, and have the structure of, super-Virasoro singular vectors. We discuss potential applications of super-quantum curves and prospects of other generalizations.