WorldWideScience

Sample records for sulf-x process

  1. Multi-tasking Sulf1/Sulf2 enzymes do not only facilitate extracellular cell signalling but also participate in cell cycle related nuclear events.

    Science.gov (United States)

    Krishnakumar, Kavithanjali; Chakravorty, Ishani; Foy, Wendy; Allen, Steve; Justo, Tiago; Mukherjee, Abir; Dhoot, Gurtej K

    2018-03-01

    This study demonstrates highly dynamic spatial and temporal pattern of SULF1/SULF2 expression in a number of neuronal cell types growing in normal culture medium that included their transient nuclear mobilisation. Their nuclear translocation became particularly apparent during cell proliferation as both SULF1/SULF2 demonstrated not only cell membrane associated expression, their known site of function but also transient nuclear mobilisation during nuclear cell division. Nuclear localisation was apparent not only by immunocytochemical staining but also confirmed by immunoblotting staining of isolated nuclear fractions of C6, U87 and N2A cells. Immunocytochemical analysis demonstrated rapid nuclear exit of both SULF1/SULF2 following cell division that was slightly delayed but not blocked in a fraction of the polyploid cells observed in C6 cells. The overexpression of both Sulf1 and Sulf2 genes in C6 and U87 cells markedly promoted in vitro growth of these cells accompanied by nuclear mobilisation while inhibition of both these genes inhibited cell proliferation with little or no nuclear SULF1/SULF2 mobilisation. SULF1/SULF2 activity in these cells thus demonstrated a clear co-ordination of extracellular cell signalling with nuclear events related to cell proliferation. Crown Copyright © 2018. Published by Elsevier Inc. All rights reserved.

  2. The SULFs, extracellular sulfatases for heparan sulfate, promote the migration of corneal epithelial cells during wound repair.

    Directory of Open Access Journals (Sweden)

    Inna Maltseva

    Full Text Available Corneal epithelial wound repair involves the migration of epithelial cells to cover the defect followed by the proliferation of the cells to restore thickness. Heparan sulfate proteoglycans (HSPGs are ubiquitous extracellular molecules that bind to a plethora of growth factors, cytokines, and morphogens and thereby regulate their signaling functions. Ligand binding by HS chains depends on the pattern of four sulfation modifications, one of which is 6-O-sulfation of glucosamine (6OS. SULF1 and SULF2 are highly homologous, extracellular endosulfatases, which post-synthetically edit the sulfation status of HS by removing 6OS from intact chains. The SULFs thereby modulate multiple signaling pathways including the augmentation of Wnt/ß-catenin signaling. We found that wounding of mouse corneal epithelium stimulated SULF1 expression in superficial epithelial cells proximal to the wound edge. Sulf1⁻/⁻, but not Sulf2⁻/⁻, mice, exhibited a marked delay in healing. Furthermore, corneal epithelial cells derived from Sulf1⁻/⁻ mice exhibited a reduced rate of migration in repair of a scratched monolayer compared to wild-type cells. In contrast, human primary corneal epithelial cells expressed SULF2, as did a human corneal epithelial cell line (THCE. Knockdown of SULF2 in THCE cells also slowed migration, which was restored by overexpression of either mouse SULF2 or human SULF1. The interchangeability of the two SULFs establishes their capacity for functional redundancy. Knockdown of SULF2 decreased Wnt/ß-catenin signaling in THCE cells. Extracellular antagonists of Wnt signaling reduced migration of THCE cells. However in SULF2- knockdown cells, these antagonists exerted no further effects on migration, consistent with the SULF functioning as an upstream regulator of Wnt signaling. Further understanding of the mechanistic action of the SULFs in promoting corneal repair may lead to new therapeutic approaches for the treatment of corneal injuries.

  3. SULF2 strongly prediposes to fasting and postprandial triglycerides in patients with obesity and type 2 diabetes mellitus.

    Science.gov (United States)

    Hassing, H Carlijne; Surendran, R Preethi; Derudas, Bruno; Verrijken, An; Francque, Sven M; Mooij, Hans L; Bernelot Moens, Sophie J; Hart, Leen M 't; Nijpels, Giel; Dekker, Jacqueline M; Williams, Kevin Jon; Stroes, Erik S G; Van Gaal, Luc F; Staels, Bart; Nieuwdorp, Max; Dallinga-Thie, Geesje M

    2014-05-01

    Hepatic overexpression of sulfatase-2 (SULF2), a heparan sulfate remodeling enzyme, strongly contributes to high triglyceride (TG) levels in obese, type 2 diabetic (T2DM) db/db mice. Nevertheless, data in humans are lacking. Here, the association of human hepatic SULF2 expression and SULF2 gene variants with TG metabolism in patients with obesity and/or T2DM was investigated. Liver biopsies from 121 obese subjects were analyzed for relations between hepatic SULF2 mRNA levels and plasma TG. Associations between seven SULF2 tagSNPs and TG levels were assessed in 210 obese T2DM subjects with dyslipidemia. Replication of positive findings was performed in 1,316 independent obese T2DM patients. Postprandial TRL clearance was evaluated in 29 obese T2DM subjects stratified by SULF2 genotype. Liver SULF2 expression was significantly associated with fasting plasma TG (r = 0.271; P = 0.003) in obese subjects. The SULF2 rs2281279(A>G) SNP was reproducibly associated with lower fasting plasma TG levels in obese T2DM subjects (P obesity and T2DM. Copyright © 2013 The Obesity Society.

  4. SULF2 Strongly Prediposes to Fasting and Postprandial Triglycerides in Patients with Obesity and Type 2 Diabetes Mellitus

    Science.gov (United States)

    Hassing, H. Carlijne; Surendran, R. Preethi; Derudas, Bruno; Verrijken, An; Francque, Sven M.; Mooij, Hans L.; Bernelot Moens, Sophie J.; ’t Hart, Leen M.; Nijpels, Giel; Dekker, Jacqueline M.; Williams, Kevin Jon; Stroes, Erik S. G.; Van Gaal, Luc F.; Staels, Bart; Nieuwdorp, Max; Dallinga-Thie, Geesje M.

    2014-01-01

    Objective Hepatic overexpression of sulfatase-2 (SULF2), a heparan sulfate remodelling enzyme, strongly contributes to high triglyceride (TG) levels in obese, type 2 diabetic (T2DM) db/db mice. Nevertheless, data in humans are lacking. Here we sought to investigate the association of human hepatic SULF2 expression and SULF2 gene variants with TG metabolism in patients with obesity and/or T2DM. Design and Methods Liver biopsies from 121 obese subjects were analyzed for relations between hepatic SULF2 mRNA levels and plasma TG. Associations between seven SULF2 tagSNPs and TG levels were assessed in 210 obese T2DM subjects with dyslipidemia. Replication of positive findings was performed in 1316 independent obese T2DM patients. Postprandial TRL clearance was evaluated in 29 obese T2DM subjects stratified by SULF2 genotype. Results Liver SULF2 expression was significantly associated with fasting plasma TG (r = 0.271; p=0.003) in obese subjects. The SULF2 rs2281279(A>G) SNP was reproducibly associated with lower fasting plasma TG levels in obese T2DM subjects (p<0.05). Carriership of the minor G allele was associated with lower levels of postprandial plasma TG (P<0.05) and retinyl esters (RE) levels (P<0.001). Conclusions These findings implicate SULF2 as potential therapeutic target in the atherogenic dyslipidemia of obesity and T2DM. PMID:24339435

  5. SULF 1 gene polymorphism, rs6990375 is in significant association with fetus failure in IVF technique

    Directory of Open Access Journals (Sweden)

    Eskandar Taghizadeh

    2015-03-01

    Full Text Available Background: Sulfatase 1 (SULF1 function is to remove the 6-O-sulphate group from heparan sulfate. This action changes the binding sites of extracellular growth factors. SULF1 expression has been reported to be changed in angiogenesis. We hypothesized that single nucleotide polymorphisms (SNPs of SULF1 would impact clinicopathologic characteristics. Objective: Study of SULF1 gene polymorphism with fetus failure in in vitro fertilization (IVF technique. Materials and Methods: We studied one common (minor allele frequency >0.05 regulatory SNP, rs6990375, with polymerase chain reaction and restriction fragment length polymorphism method, in 53 infertile women with fetus failure in IVF technique and 53 women with at least one healthy child as controls. Results: We found that rs6990375 is significantly associated with an early failure in IVF and frequency of G allele is high in women with fetus failure in IVF technique (p<0.001. Conclusion: These findings suggest that SULF1genetic variations may play a role in IVF technique fetus failure. Further studies with large sample sizes on SULF1 SNPs may be useful in support of this claim.

  6. SULF2 strongly prediposes to fasting and postprandial triglycerides in patients with obesity and type 2 diabetes mellitus

    NARCIS (Netherlands)

    Hassing, H. Carlijne; Surendran, R. Preethi; Derudas, Bruno; Verrijken, An; Francque, Sven M.; Mooij, Hans L.; Bernelot Moens, Sophie J.; Hart, Leen M. 't; Nijpels, Giel; Dekker, Jacqueline M.; Williams, Kevin Jon; Stroes, Erik S. G.; van Gaal, Luc F.; Staels, Bart; Nieuwdorp, Max; Dallinga-Thie, Geesje M.

    2014-01-01

    Hepatic overexpression of sulfatase-2 (SULF2), a heparan sulfate remodeling enzyme, strongly contributes to high triglyceride (TG) levels in obese, type 2 diabetic (T2DM) db/db mice. Nevertheless, data in humans are lacking. Here, the association of human hepatic SULF2 expression and SULF2 gene

  7. SULF2 Strongly Prediposes to Fasting and Postprandial Triglycerides in Patients with Obesity and Type 2 Diabetes Mellitus

    NARCIS (Netherlands)

    Hassing, H.C.; Surendran, R.P.; Derudas, B.; Verrijken, A.; Francque, S.M.; Mooij, H.L.; Moens, S.J.B.; 't Hart, L.M.; Nijpels, G.; Dekker, J.M.; Williams, K.J.; Stroes, E.S.G.; van Gaal, L.F.; Staels, B.; Nieuwdorp, M.; Dallinga-Thie, G.M.

    2014-01-01

    Objective Hepatic overexpression of sulfatase-2 (SULF2), a heparan sulfate remodeling enzyme, strongly contributes to high triglyceride (TG) levels in obese, type 2 diabetic (T2DM) db/db mice. Nevertheless, data in humans are lacking. Here, the association of human hepatic SULF2 expression and SULF2

  8. Evaluación del pretratamiento con ácido sulfúrico diluido del pasto maralfalfa (Pennisetum glaucum x Pennisetum purpureum para la producción de etanol

    Directory of Open Access Journals (Sweden)

    Lady Mateus

    2012-01-01

    Full Text Available Título en ingles: Dilute sulfuric acid pretreatment of goliath grass (Pennisetum glaucum x Pennisetum purpureum for ethanol cellulosic Resumen : Evaluar la producción de etanol a partir de cultivos lignocelulósicos, específicamente pastos de rápido crecimiento en la región, constituye una alternativa a la demanda de biocombustibles. En la presente investigación se seleccionó el pasto Maralfalfa (Pennisetum  glaucum x Pennisetum  purpureum utilizando el pretratamiento con ácido sulfúrico diluido a diferentes temperaturas (110, 130, 150, 170 y 190 °C y concentraciones de ácido (0.8, 1.2 y 2.0% (p/p, seguido de un proceso de hidrólisis enzimática utilizando celulasas y celobiosas comerciales y un proceso de hidrólisis y fermentación simultanea. La máxima producción de etanol obtenido fue 117 mg etanol/ g biomasa pretratada a 190 °C y 1,2 %(p/p de ácido sulfúrico. El líquido hidrolizado fue caracterizado calculando el porcentaje de glucosa, xilosa y lignina solubilizadas y degradadas durante el pretratamiento. Palabras clave: etanol lignocelulósico; celulosa; hemicelulosa. Abstract: The goliath grass (Pennisetum  glaucum x Pennisetum  purpureum was pretreated with different sulfuric acid concentrations (0.8, 1.2 y 2.0% (w/w from low to high temperatures (110, 130, 150, 170 y 190 °C followed by enzymatic hydrolysis and SSF of remaining solids. The maximum yield was 117 mg of ethanol/g biomass to 190 °C and 1.2 % (w/w of sulfuric acid. Key words: lignocellulosic ethanol; hemicelluloses; cellulose.

  9. iSulf-Cys: Prediction of S-sulfenylation Sites in Proteins with Physicochemical Properties of Amino Acids.

    Science.gov (United States)

    Xu, Yan; Ding, Jun; Wu, Ling-Yun

    2016-01-01

    Cysteine S-sulfenylation is an important post-translational modification (PTM) in proteins, and provides redox regulation of protein functions. Bioinformatics and structural analyses indicated that S-sulfenylation could impact many biological and functional categories and had distinct structural features. However, major limitations for identifying cysteine S-sulfenylation were expensive and low-throughout. In view of this situation, the establishment of a useful computational method and the development of an efficient predictor are highly desired. In this study, a predictor iSulf-Cys which incorporated 14 kinds of physicochemical properties of amino acids was proposed. With the 10-fold cross-validation, the value of area under the curve (AUC) was 0.7155 ± 0.0085, MCC 0.3122 ± 0.0144 on the training dataset for 20 times. iSulf-Cys also showed satisfying performance in the independent testing dataset with AUC 0.7343 and MCC 0.3315. Features which were constructed from physicochemical properties and position were carefully analyzed. Meanwhile, a user-friendly web-server for iSulf-Cys is accessible at http://app.aporc.org/iSulf-Cys/.

  10. Drosophila Sulf1 is required for the termination of intestinal stem cell division during regeneration.

    Science.gov (United States)

    Takemura, Masahiko; Nakato, Hiroshi

    2017-01-15

    Stem cell division is activated to trigger regeneration in response to tissue damage. The molecular mechanisms by which this stem cell mitotic activity is properly repressed at the end of regeneration are poorly understood. Here, we show that a specific modification of heparan sulfate is crucial for regulating Drosophila intestinal stem cell (ISC) division during normal midgut homeostasis and regeneration. Loss of the extracellular heparan sulfate endosulfatase Sulf1 resulted in increased ISC division during normal homeostasis, which was caused by upregulation of mitogenic signaling including the JAK-STAT, EGFR and Hedgehog pathways. Using a regeneration model, we found that ISCs failed to properly halt division at the termination stage in Sulf1 mutants, showing that Sulf1 is required for terminating ISC division at the end of regeneration. We propose that post-transcriptional regulation of mitogen signaling by heparan sulfate structural modifications provides a new regulatory step for precise temporal control of stem cell activity during regeneration. © 2017. Published by The Company of Biologists Ltd.

  11. Oligosaccharide substrate preferences of human extracellular sulfatase Sulf2 using liquid chromatography-mass spectrometry based glycomics approaches.

    Directory of Open Access Journals (Sweden)

    Yu Huang

    Full Text Available Sulfs are extracellular endosulfatases that selectively remove the 6-O-sulfate groups from cell surface heparan sulfate (HS chain. By altering the sulfation at these particular sites, Sulfs function to remodel HS chains. As a result of the remodeling activity, HSulf2 regulates a multitude of cell-signaling events that depend on interactions between proteins and HS. Previous efforts to characterize the substrate specificity of human Sulfs (HSulfs focused on the analysis of HS disaccharides and synthetic repeating units. In this study, we characterized the substrate preferences of human HSulf2 using HS oligosaccharides with various lengths and sulfation degrees from several naturally occurring HS sources by applying liquid chromatography mass spectrometry based glycomics methods. The results showed that HSulf2 preferentially digests highly sulfated HS oligosaccharides with zero acetyl groups and this preference is length dependent. In terms of length of oligosaccharides, HSulf2 digestion induced more sulfation decrease on DP6 (DP: degree of polymerization compared to DP2, DP4 and DP8. In addition, the HSulf2 preferentially digests the oligosaccharide domain located at the non-reducing end (NRE of the HS and heparin chain. In addition, the HSulf2 digestion products were altered only for specific isomers. HSulf2 treated NRE oligosaccharides also showed greater decrease in cell proliferation than those from internal domains of the HS chain. After further chromatographic separation, we identified the three most preferred unsaturated hexasaccharide for HSulf2.

  12. Produtividade do cacaueiro em função de características do solo: II. características físico-morfológicas e alguns elementos extraídos pelo ataque sulfúrico

    Directory of Open Access Journals (Sweden)

    J. O. Souza Jr.

    1999-12-01

    Full Text Available Com base na produtividade em sete anos (1989 a 1995 de 36 talhões produtivos de cacau, cultivados numa propriedade agrícola no sul da Bahia, foram obtidas as médias dos três anos mais e menos produtivos, correspondendo, respectivamente, a anos de maior e menor quantidade de chuvas. Essas produtividades foram relacionadas, por análise de trilha, com as características físico-morfológicas do solo (profundidade do horizonte A; cor, porosidade, densidades aparente e de partícula dos horizontes A e B; textura das camadas de 0-20 e 30-50 cm e presença de cascalho ou pedras até à profundidade de 50 cm e com os teores totais de elementos (Ti, K, Cu, Fe, Mn e Zn, obtidos pelo ataque sulfúrico, na camada de 30-50 cm de profundidade. Os micronutrientes extraídos pelo ataque sulfúrico foram correlacionados com aqueles extraídos pelo Mehlich-1. Em geral, as características físicas explicaram melhor a produtividade dos anos mais secos, enquanto os teores de elementos extraídos pelo ataque sulfúrico correlacionaram-se melhor com a produtividade dos anos mais chuvosos. Os talhões mais produtivos tinham horizonte A mais profundo, solo mais poroso, com maiores teores de micronutrientes catiônicos e Ti e menor teor de K obtido pelo ataque sulfúrico. Em anos mais secos, os talhões mais produtivos foram aqueles que apresentavam solo com maior teor de argila e menores teores de silte e areia. A presença de cascalho até à profundidade de 50 cm e a cor dos horizontes do solo não se correlacionaram significativamente com a produtividade das plantas. Cobre, Mn e, ou, Zn, extraídos pelo ataque sulfúrico, indicaram solos de maior fertilidade natural em micronutrientes catiônicos para o cacaueiro.

  13. HYBRID SULFUR RECOVERY PROCESS FOR NATURAL GAS UPGRADING

    International Nuclear Information System (INIS)

    Girish Srinivas; Steven C. Gebhard; David W. DeBerry

    2001-01-01

    This first quarter report of 2001 describes progress on a project funded by the U.S. Department of Energy (DOE) to test a hybrid sulfur recovery process for natural gas upgrading. The process concept represents a low cost option for direct treatment of natural gas streams to remove H(sub 2)S in quantities equivalent to 0.2-25 metric tons (LT) of sulfur per day. This process is projected to have lower capital and operating costs than the competing technologies, amine/aqueous iron liquid redox and amine/Claus/tail gas treating, and have a smaller plant footprint, making it well suited to both on-shore and offshore applications. CrystaSulf(trademark) (service mark of Gas Research Institute) is a new nonaqueous sulfur recovery process that removes hydrogen sulfide (H(sub 2)S) from gas streams and converts it into elemental sulfur. CrystaSulf features high sulfur recovery similar to aqueous-iron liquid redox sulfur recovery processes, but differs from the aqueous processes in that CrystaSulf controls the location where elemental sulfur particles are formed. In the hybrid process, approximately 1/3 of the total H(sub 2)S in the natural gas is first oxidized to SO(sub 2) at low temperatures over a heterogeneous catalyst. Low temperature oxidation is done so that the H(sub 2)S can be oxidized in the presence of methane and other hydrocarbons without oxidation of the hydrocarbons. The project involves the development of a catalyst using laboratory/bench-scale catalyst testing, and then demonstration of the catalyst at CrystaTech's pilot plant in west Texas. During this reporting periods new catalyst formulations were tested. The experiments showed that the newest catalyst has slightly better performance, but catalyst TDA No.2 is still superior overall for use with the hybrid CrystaSulf process due to lower costs. Plans for catalyst pelletization and continued testing are described

  14. An oncolytic adenovirus regulated by a radiation-inducible promoter selectively mediates hSulf-1 gene expression and mutually reinforces antitumor activity of I131-metuximab in hepatocellular carcinoma.

    Science.gov (United States)

    Zhang, Yan; Fang, Lin; Zhang, Quan'an; Zheng, Qin; Tong, Jinlong; Fu, Xiaohui; Jiang, Xiaoqing; Su, Changqing; Zheng, Junnian

    2013-06-01

    Gene therapy and antibody approaches are crucial auxiliary strategies for hepatocellular carcinoma (HCC) treatment. Previously, we established a survivin promoter-regulated oncolytic adenovirus that has inhibitory effect on HCC growth. The human sulfatase-1 (hSulf-1) gene can suppress the growth factor signaling pathways, then inhibit the proliferation of cancer cells and enhance cellular sensitivity to radiotherapy and chemotherapy. I(131)-metuximab (I(131)-mab) is a monoclonal anti-HCC antibody that conjugated to I(131) and specifically recognizes the HAb18G/CD147 antigen on HCC cells. To integrate the oncolytic adenovirus-based gene therapy and the I(131)-mab-based radioimmunotherapy, this study combined the CArG element of early growth response-l (Egr-l) gene with the survivin promoter to construct a radiation-inducible enhanced promoter, which was used to recombine a radiation-inducible oncolytic adenovirus as hSulf-1 gene vector. When I(131)-mab was incorporated into the treatment regimen, not only could the antibody produce radioimmunotherapeutic effect, but the I(131) radiation was able to further boost adenoviral proliferation. We demonstrated that the CArG-enhanced survivin promoter markedly improved the proliferative activity of the oncolytic adenovirus in HCC cells, thereby augmenting hSulf-1 expression and inducing cancer cell apoptosis. This novel strategy that involved multiple, synergistic mechanisms, including oncolytic therapy, gene therapy and radioimmunotherapy, was demonstrated to exert an excellent anti-cancer outcome, which will be a promising approach in HCC treatment. Copyright © 2012 Federation of European Biochemical Societies. Published by Elsevier B.V. All rights reserved.

  15. Cálculo de las concentraciones de una mezcla de ácido nítrico y ácido sulfúrico. Problema interactivo.

    OpenAIRE

    Milla González, Miguel

    2012-01-01

    Partiendo de una mezcla ácida compuesta por ácido nítrico y ácido sulfúrico, se calcula la concentración de ambos ácidos mediante una valoración ácido-base conjunta para ambas especies y una valoración por retroceso en la que el nitrato es reducido a amoníaco, recogido sobre HCl y valorado el exceso de éste. Deben construirse las ecuaciones adecuadas para la resolución correcta. Los resultados son comprobados por el sistema.

  16. Electrolisis de una disolución de ácido sulfúrico con empleo de electrodos de Cu. Práctica simulada interactiva.

    OpenAIRE

    Milla González, Miguel

    2010-01-01

    En esta práctica simulada se realiza la electrolisis de una disolución de ácido sulfúrico 0.1 M utilizando electrodos de cobre. Para ello se hace el montaje experimental (mostrado mediante una sucesión de fotos) y se pesa previamente el ánodo que está constituido por una lámina de cobre. El experimento se inicia encendiendo la fuente de tensión. En este momento comienzan las reacciones redox en cátodo y ánodo. El proceso puede detenerse en cualquier instante, pero es aconsejable hacerlo para ...

  17. Development of an Integrated Multi-Contaminant Removal Process Applied to Warm Syngas Cleanup for Coal-Based Advanced Gasification Systems

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Howard

    2010-11-30

    This project met the objective to further the development of an integrated multi-contaminant removal process in which H2S, NH3, HCl and heavy metals including Hg, As, Se and Cd present in the coal-derived syngas can be removed to specified levels in a single/integrated process step. The process supports the mission and goals of the Department of Energy's Gasification Technologies Program, namely to enhance the performance of gasification systems, thus enabling U.S. industry to improve the competitiveness of gasification-based processes. The gasification program will reduce equipment costs, improve process environmental performance, and increase process reliability and flexibility. Two sulfur conversion concepts were tested in the laboratory under this project, i.e., the solventbased, high-pressure University of California Sulfur Recovery Process High Pressure (UCSRP-HP) and the catalytic-based, direct oxidation (DO) section of the CrystaSulf-DO process. Each process required a polishing unit to meet the ultra-clean sulfur content goals of <50 ppbv (parts per billion by volume) as may be necessary for fuel cells or chemical production applications. UCSRP-HP was also tested for the removal of trace, non-sulfur contaminants, including ammonia, hydrogen chloride, and heavy metals. A bench-scale unit was commissioned and limited testing was performed with simulated syngas. Aspen-Plus®-based computer simulation models were prepared and the economics of the UCSRP-HP and CrystaSulf-DO processes were evaluated for a nominal 500 MWe, coal-based, IGCC power plant with carbon capture. This report covers the progress on the UCSRP-HP technology development and the CrystaSulf-DO technology.

  18. HYBRID SULFUR RECOVERY PROCESS FOR NATURAL GAS UPGRADING

    International Nuclear Information System (INIS)

    Girish Srinivas; Steven C. Gebhard; David W. DeBerry

    2002-01-01

    This first quarter report of 2002 describes progress on a project funded by the U.S. Department of Energy (DOE) to test a hybrid sulfur recovery process for natural gas upgrading. The process concept represents a low cost option for direct treatment of natural gas streams to remove H(sub 2)S in quantities equivalent to 0.2-25 metric tons (LT) of sulfur per day. This process is projected to have lower capital and operating costs than the competing technologies, amine/aqueous iron liquid redox and amine/Claus/tail gas treating, and have a smaller plant footprint, making it well suited to both on-shore and offshore applications. CrystaSulf(sup SM) (service mark of CrystaTech, Inc.) is a new nonaqueous sulfur recovery process that removes hydrogen sulfide (H(sub 2)S) from gas streams and converts it into elemental sulfur. CrystaSulf features high sulfur recovery similar to aqueous-iron liquid redox sulfur recovery processes, but differs from the aqueous processes in that CrystaSulf controls the location where elemental sulfur particles are formed. In the hybrid process, approximately 1/3 of the total H(sub 2)S in the natural gas is first oxidized to SO(sub 2) at low temperatures over a heterogeneous catalyst. Low temperature oxidation is done so that the H(sub 2)S can be oxidized in the presence of methane and other hydrocarbons without oxidation of the hydrocarbons. The project involves the development of a catalyst using laboratory/bench-scale catalyst testing, and then demonstration of the catalyst at CrystaTech's pilot plant in west Texas. In a previous reporting period tests were done to determine the effect of hydrocarbons such as n-hexane on catalyst performance with and without H(sub 2)S present. The experiments showed that hexane oxidation is suppressed when H(sub 2)S is present. Hexane represents the most reactive of the C1 to C6 series of alkanes. Since hexane exhibits low reactivity under H(sub 2)S oxidation conditions, and more importantly, does not change

  19. Adsorption of sulphuric acid on smectite from acidic aqueous solutions Adsorção de ácido sulfúrico em esmectita de soluções aquosas ácidas

    Directory of Open Access Journals (Sweden)

    E. L. Tavani

    1999-05-01

    Full Text Available The adsorption of sulphuric acid on smectite from acidic aqueous solutions was studied. The amounts of cations dissolved in each equilibrium solution were determined by chemical analysis. Simultaneously, the original smectite and the smectite after each test were characterized by infrared, X-ray diffraction and swelling index. The results obtained permitted us to determine that the substitutions of the exchange cations and the chemical attack occurred at very different acid concentrations and treatment times. It was established that during the acid treatment of the smectite, a progressive damage of its crystalline structure was produced. Finally, the influences of the substitution of exchange cations and of the chemical attack in the swelling index were determined.A adsorção de ácido sulfúrico em esmectita de soluções aquosas ácidas é estudada. As concentrações de cátions dissolvidos em cada solução em equilíbrio foram determinadas por análise química. As esmectitas original e após cada teste foram simultaneamente caracterizadas por infravermelho, difração de raios X e índice de crescimento. Os resultados obtidos permitiram determinar que as substituições dos cátions de troca e o ataque químico ocorreram em diferentes concentrações de ácido e tempos de tratamento. Foi verificado que durante o tratamento em ácido da esmectita foi produzido um dano progressivo da sua estrutura cristalina. Finalmente foram determinadas as influências da substituição dos cátions de troca e do ataque químico no índice de crescimento.

  20. PROPOSAL FOR THE IMPLEMENTATION OF SPRAY DRYING IN THE ACTIVATION PROCESS OF BENTONITE WITH SULFURIC ACID

    OpenAIRE

    Romero, P.; Otiniano, M.

    2014-01-01

    The present work propose the replacement of the three stages of the activation process of bentonite with sulfuric acid by the only stage spray drying. El presente trabajo propone reemplazar tres etapas del proceso de activación de la bentonita con ácido sulfúrico por una sola etapa, la del secado por atomización.

  1. Biofiltração de compostos orgânicos voláteis e gás sulfídrico em estações de despejos industriais de processamento de hidrocarbonetos.

    OpenAIRE

    Beatrix Nery Villa Martignoni

    2007-01-01

    Neste trabalho foi estudado o tratamento simultâneo por biofiltração de emissões de compostos orgânicos voláteis, COV e gás sulfídrico, H2S, em estações de tratamento de despejos industriais, de refinaria de petróleo, ETDI. A biofiltração dos gases emanados da EDTI mostrou ser uma técnica de alta eficiência, atingindo valores de 95 a 99 % para tratamento simultâneo de COV e H2S em concentrações de 1000 e 100 ppmv, respectivamente. Foram realizados testes em 95 dias consecutivos...

  2. X-ray data processing

    OpenAIRE

    Powell, Harold R.

    2017-01-01

    The method of molecular structure determination by X-ray crystallography is a little over a century old. The history is described briefly, along with developments in X-ray sources and detectors. The fundamental processes involved in measuring diffraction patterns on area detectors, i.e. autoindexing, refining crystal and detector parameters, integrating the reflections themselves and putting the resultant measurements on to a common scale are discussed, with particular reference to the most c...

  3. X-ray data processing.

    Science.gov (United States)

    Powell, Harold R

    2017-10-31

    The method of molecular structure determination by X-ray crystallography is a little over a century old. The history is described briefly, along with developments in X-ray sources and detectors. The fundamental processes involved in measuring diffraction patterns on area detectors, i.e. autoindexing, refining crystal and detector parameters, integrating the reflections themselves and putting the resultant measurements on to a common scale are discussed, with particular reference to the most commonly used software in the field. © 2017 The Author(s).

  4. Radiation processing with high-energy X-rays

    International Nuclear Information System (INIS)

    Cleland, Marshall R.; Stichelbaut, Frederic

    2009-01-01

    The physical, chemical or biological characteristics of selected commercial products and materials can be improved by radiation processing. The ionizing energy can be provided by accelerated electrons with energies between 75 keV and 10 MeV, gamma rays from cobalt-60 with average energies of 1.25 MeV or X-rays with maximum energies up to 7.5 MeV. Electron beams are preferred for thin products, which are processed at high speeds. Gamma rays are used for products that are too thick for treatment with electron beams. High-energy X-rays can also be used for these purposes because their penetration in solid materials is similar to or even slightly greater than that of gamma rays. Previously, the use of X-rays had been inhibited by their slower processing rates and higher costs when compared with gamma rays. Since then, the price of cobalt-60 sources has been increased and the radiation intensity from high-energy, high-power X-ray generators has also increased. For facilities requiring at least 2 MCi of cobalt-60, the capital and operating costs of X-ray facilities with equivalent processing rates can be less than that of gamma-ray irradiators. Several high-energy electron beam facilities have been equipped with removable X-ray targets so that irradiation processes can be done with either type of ionizing energy. A new facility is now being built which will be used exclusively in the X-ray mode to sterilize medical products. Operation of this facility will show that high-energy, high-power X-ray generators are practical alternatives to large gamma-ray sources. (author)

  5. Correlações para estimativas de custos na remoção de ácido sulfídrico de biogás = Correlations for cost estimates in the sulfidric acid removal from biogas

    Directory of Open Access Journals (Sweden)

    Laercio Mantovani Frare

    2006-01-01

    Full Text Available As estimativas de custos durante os estudos para a implementação de um novo processo químico é uma das fases críticas que determinam se o empreendimento será viável ou não. Neste trabalho foi desenvolvida uma metodologia capaz de estimar os custos e investimentos envolvidos em um processo de remoção de ácido sulfídrico de biogás. Ametodologia aplicada utilizou uma estimativa de custos fundamentada em equipamentos nacionais e nas correlações propostas por Guthrie (1969, Turton et al. (2003 e Perlingeiro (2005. Esta permite avaliar, de maneira rápida e precisa, diferentes configurações deequipamentos durante a etapa de projeto do processo, determinando assim o custo final do metro cúbico de biogás purificado.Cost estimates during studies in order to implement a new chemical process are a critical stage that determines whether the process will be viable or not. This study developed a methodology to estimate the costs and investments necessary in the process of removing hydrogen sulfide from biogas. The applied methodology used cost estimatesbased on costs of national equipments and correlations proposed by Guthrie (1969, Turton et al. (2003 and Perlingeiro (2005. The methodology allowed rapid and precise evaluation, different configuration of equipments for the process project, thus establishing the cost of cubic meter of purified biogas.

  6. Automated processing of X-ray images in medicine

    International Nuclear Information System (INIS)

    Babij, Ya.S.; B'yalyuk, Ya.O.; Yanovich, I.A.; Lysenko, A.V.

    1991-01-01

    Theoretical and practical achievements in application of computing technology means for processing of X-ray images in medicine were generalized. The scheme of the main directions and tasks of processing of X-ray images was given and analyzed. The principal problems appeared in automated processing of X-ray images were distinguished. It is shown that for interpretation of X-ray images it is expedient to introduce a notion of relative operating characteristic (ROC) of a roentgenologist. Every point on ROC curve determines the individual criteria of roentgenologist to put a positive diagnosis for definite situation

  7. Ácido sulfúrico superação da dormência de unidade de dispersão de juazeiro (Zizyphus joazeiro Mart. The use of sulfuric acid to break dispersal unit dormancy of Zizyphus joazeiro Mart.

    Directory of Open Access Journals (Sweden)

    Edna Ursulino Alves

    2006-04-01

    Full Text Available O Zizyphus joazeiro Mart. apresenta redução sensível no número de indivíduos em seu ambiente natural devido, entre outras causas, à ocorrência de dormência exógena da unidade de dispersão (impermeabilidade à água. Avaliou-se o efeito do período de imersão (0, 30, 60, 90, 120 e 150 min dessas unidades de dispersão, em ácido sulfúrico (98 %, na emergência e vigor das sementes (primeira contagem, índice de velocidade e tempo médio de emergência, altura e massa seca de plantas. O experimento foi realizado em casa de vegetação, utilizando-se o delineamento inteiramente ao acaso, com seis tratamentos e quatro repetições. O pré-condicionamento das unidades de dispersão de Zizyphus joazeiro Mart., em ácido sulfúrico concentrado, mostrou-se eficiente na superação da dormência dessa espécie, promovendo aumento na porcentagem e velocidade de emergência, primeira contagem de emergência, na altura e massa seca de plantas e redução no tempo médio para emergência. A eficiência do tratamento químico com ácido sulfúrico concentrado depende do período de imersão, sendo a faixa entre 74 e 115 min mais adequada para proporcionar maiores porcentagens de emergência e de vigor.Zizyphus joazeiro Mart. trees have been declining in number in their natural habitat due to, among other reasons, the occurrence of dormancy of dispersal units (water impermeability. The effect of the immersion time (0, 30, 60, 90, 120 and 150 minutes of Zizyphus joazeiro Mart. dispersal units in concentrated sulfuric acid (95-98 % was evaluated through the emergency and vigor (first count, speed index and mean emergence time, plant height and dry matter weight. The experiment was performed under greenhouse conditions, with a completely randomized experimental design, six treatments and four replications. The pre-conditioning of Zizyphus joazeiro Mart. dispersal units with immersion in concentrated sulfuric acid was efficient for breaking the seed

  8. Structure and expression of sulfatase and sulfatase modifying factor genes in the diamondback moth, Plutella xylostella.

    Science.gov (United States)

    Ma, Xiao-Li; He, Wei-Yi; Chen, Wei; Xu, Xue-Jiao; Qi, Wei-Ping; Zou, Ming-Min; You, Yan-Chun; Baxter, Simon W; Wang, Ping; You, Min-Sheng

    2017-06-01

    The diamondback moth, Plutella xylostella (L.), uses sulfatases (SULF) to counteract the glucosinolate-myrosinase defensive system that cruciferous plants have evolved to deter insect feeding. Sulfatase activity is regulated by post-translational modification of a cysteine residue by sulfatase modifying factor 1 (SUMF1). We identified 12 SULF genes (PxylSulfs) and two SUMF1 genes (PxylSumf1s) in the P. xylostella genome. Phylogenetic analysis of SULFs and SUMFs from P. xylostella, Bombyx mori, Manduca sexta, Heliconius melpomene, Danaus plexippus, Drosophila melanogaster, Tetranychus urticae and Homo sapiens showed that the SULFs were clustered into five groups, and the SUMFs could be divided into two groups. Profiling of the expression of PxylSulfs and PxylSumfs by RNA-seq and by quantitative real-time polymerase chain reaction showed that two glucosinolate sulfatase genes (GSS), PxylSulf2 and PxylSulf3, were primarily expressed in the midgut of 3rd- and 4th-instar larvae. Moreover, expression of sulfatases PxylSulf2, PxylSulf3 and PxylSulf4 were correlated with expression of the sulfatases modifying factor PxylSumf1a. The findings from this study provide new insights into the structure and expression of SUMF1 and PxylSulf genes that are considered to be key factors for the evolutionary success of P. xylostella as a specialist herbivore of cruciferous plants. © 2017 Institute of Zoology, Chinese Academy of Sciences.

  9. Catalisadores Sulfônicos Imobilizados em Polímeros: Síntese, Caracterização e Avaliação

    Directory of Open Access Journals (Sweden)

    Coutinho Fernanda M.B.

    2001-01-01

    Full Text Available Suportes poliméricos à base de estireno (Sty e divinilbenzeno (DVB foram preparados por polimerização em suspensão aquosa em presença de diluente (mistura de tolueno e n-heptano em composição variada em um grau de diluição de 100 % e com quatro teores diferentes de DVB (10, 20, 40 e 60 %. Os suportes foram caracterizados nos estados seco e inchado. No estado seco foram analisados quanto à densidade aparente, área específica, volume de poros e morfologia, e no estado inchado foi observado o comportamento em dois diferentes tipos de solventes, um bom e um mau solvente para o copolímero de estireno-divinilbenzeno. As propriedades dos suportes poliméricos, nos estados seco e inchado, foram relacionadas com os parâmetros de síntese. Os suportes poliméricos foram sulfonados em presença de solvente capaz de inchar a rede polimérica (1,2-dicloroetano. Os catalisadores sulfônicos obtidos foram caracterizados no estado seco e inchado e a atividade catalítica foi avaliada em reações de esterificação de ácido acético com n-butanol. Também foi avaliado o efeito da reciclagem dos catalisadores na sua atividade catalítica.

  10. Apparatus and method X-ray image processing

    International Nuclear Information System (INIS)

    1984-01-01

    The invention relates to a method for X-ray image processing. The radiation passed through the object is transformed into an electric image signal from which the logarithmic value is determined and displayed by a display device. Its main objective is to provide a method and apparatus that renders X-ray images or X-ray subtraction images with strong reduction of stray radiation. (Auth.)

  11. Consolidation processing parameters and alternative processing methods for powder metallurgy Al-Cu-Mg-X-X alloys

    Science.gov (United States)

    Sankaran, K. K.

    1987-01-01

    The effects of varying the vacuum degassing parameters on the microstructure and properties of Al-4Cu-1Mg-X-X (X-X = 1.5Li-0.2Zr or 1.5Fe-0.75Ce) alloys processed from either prealloyed (PA) or mechanically alloyed (M) powder, and consolidated by either using sealed aluminum containers or containerless vacuum hot pressing were studied. The consolidated billets were hot extruded to evaluate microstructure and properties. The MA Li-containing alloy did not include Zr, and the MA Fe- and Ce-containing alloy was made from both elemental and partially prealloyed powder. The alloys were vacuum degassed both above and below the solution heat treatment temperature. While vacuum degassing lowered the hydrogen content of these alloys, the range over which the vacuum degassing parameters were varied was not large enough to cause significant changes in degassing efficiency, and the observed variations in the mechanical properties of the heat treated alloys were attributed to varying contributions to strengthening by the sub-structure and the dispersoids. Mechanical alloying increased the strength over that of alloys of similar composition made from PA powder. The inferior properties in the transverse orientation, especially in the Li-containing alloys, suggested deficiencies in degassing. Among all of the alloys processed for this study, the Fe- and Ce-containing alloys made from MA powder possessed better combinations of strength and toughness.

  12. Human Sulfatase 2 inhibits in vivo tumor growth of MDA-MB-231 human breast cancer xenografts

    International Nuclear Information System (INIS)

    Peterson, Sarah M; Concino, Michael F; Liaw, Lucy; Martini, Paolo GV; Iskenderian, Andrea; Cook, Lynette; Romashko, Alla; Tobin, Kristen; Jones, Michael; Norton, Angela; Gómez-Yafal, Alicia; Heartlein, Michael W

    2010-01-01

    Extracellular human sulfatases modulate growth factor signaling by alteration of the heparin/heparan sulfate proteoglycan (HSPG) 6-O-sulfation state. HSPGs bind to numerous growth factor ligands including fibroblast growth factors (FGF), epidermal growth factors (EGF), and vascular endothelial growth factors (VEGF), and are critically important in the context of cancer cell growth, invasion, and metastasis. We hypothesized that sulfatase activity in the tumor microenvironment would regulate tumor growth in vivo. We established a model of stable expression of sulfatases in the human breast cancer cell line MDA-MB-231 and purified recombinant human Sulfatase 2 (rhSulf2) for exogenous administration. In vitro studies were performed to measure effects on breast cancer cell invasion and proliferation, and groups were statistically compared using Student's t-test. The effects of hSulf2 on tumor progression were tested using in vivo xenografts with two methods. First, MDA-MB-231 cells stably expressing hSulf1, hSulf2, or both hSulf1/hSulf2 were grown as xenografts and the resulting tumor growth and vascularization was compared to controls. Secondly, wild type MDA-MB-231 xenografts were treated by short-term intratumoral injection with rhSulf2 or vehicle during tumor growth. Ultrasound analysis was also used to complement caliper measurement to monitor tumor growth. In vivo studies were statistically analyzed using Student's t test. In vitro, stable expression of hSulf2 or administration of rhSulf2 in breast cancer cells decreased cell proliferation and invasion, corresponding to an inhibition of ERK activation. Stable expression of the sulfatases in xenografts significantly suppressed tumor growth, with complete regression of tumors expressing both hSulf1 and hSulf2 and significantly smaller tumor volumes in groups expressing hSulf1 or hSulf2 compared to control xenografts. Despite significant suppression of tumor volume, sulfatases did not affect vascular

  13. Quantification of process variables for carbothermic synthesis of UC{sub 1-x}N{sub x} fuel microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Lindemer, T.B. [MPi Business Solutions, Inc., Knoxville, TN 37915 (United States); Silva, C.M.; Henry, J.J. [Materials Science and Technology Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6063 (United States); McMurray, J.W., E-mail: mcmurrayjw1@ornl.gov [Materials Science and Technology Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6063 (United States); Voit, S.L.; Collins, J.L.; Hunt, R.D. [Materials Science and Technology Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6063 (United States)

    2017-01-15

    This report details the continued investigation of process variables involved in converting sol-gel-derived, urania-carbon microspheres to ∼820-μm-dia. UC{sub 1-x}N{sub x} fuel kernels in flow-through, vertical Mo and W crucibles at temperatures up to 2123 K. Experiments included calcining of air-dried UO{sub 3}-H{sub 2}O-C microspheres in Ar and H{sub 2}-containing gases, conversion of the resulting UO{sub 2}-C kernels to dense UO{sub 2}:2UC in the same gases and vacuum, and its conversion in N{sub 2} to UC{sub 1-x}N{sub x} (x = ∼0.85). The thermodynamics of the relevant reactions were applied extensively to interpret and control the process variables. Producing the precursor UO{sub 2}:2UC kernel of ∼96% theoretical density was required, but its subsequent conversion to UC{sub 1-x}N{sub x} at 2123 K was not accompanied by sintering and resulted in ∼83–86% of theoretical density. Increasing the UC{sub 1-x}N{sub x} kernel nitride component to ∼0.98 in flowing N{sub 2}-H{sub 2} mixtures to evolve HCN was shown to be quantitatively consistent with present and past experiments and the only useful application of H{sub 2} in the entire process. - Highlights: • Sol-gel feedstock conversion to UN through carbothermic reduction. • Investigation of process gas effect on final kernel quality and density. • Recommended process for consistent kernel production.

  14. Effects of corn meal and sulphuric acid on the production of cachaça Efeitos do fubá e ácido sulfúrico sobre a produção de cachaça

    Directory of Open Access Journals (Sweden)

    Francisco Vicente Gaiotto Cleto

    2009-10-01

    Full Text Available This work was carried out to evaluate the effects of using corn meal and treating yeasts with sulfuric acid on fermentation microorganisms, wine acidity, ethanol content and cachaça yield and composition. The experiment was arranged in randomized block design, in a 2x3 factorial with five replications. The methods applied in this study are recommended by distilleries. Results showed that the yeast sulfuric acid treatment transferred acidity to the fermenting juice, without any influence on yeast viability, ethanol content and cachaça yield. On the other hand, the acid treatment controlled lactic bacteria in the inoculum. Addition of corn meal increased the concentration of lactic bacteria in the end of the fermentation and increased the levels of higher alcohols in cachaça, especially propyl and isobutyl alcohol.Avaliou-se o efeito da adição do fubá de milho no mosto de xarope de cana e o tratamento ácido do pé-de-cuba sobre a microbiota do processo fermentativo, acidez do vinho, grau alcoólico, rendimento e composição da cachaça. O delineamento experimental utilizado foi o de blocos casualizados, no esquema fatorial 2x3 e cinco repetições. A metodologia empregada e as análises foram as recomendadas pelo setor aguardenteiro. Os resultados permitiram concluir que a adição do ácido sulfúrico no pé-de-cuba transferiu a acidez para o vinho, não influenciando na viabilidade das leveduras, rendimento e composição da cachaça. Por outro lado, a acidificação do meio controlou as bactérias láticas no pé-de-cuba. A adição do fubá aumentou a concentração de bactérias lácticas ao final do processo fermentativo e dos álcoois homólogos superiores na cachaça, particularmente, os álcoois propílico e isobutílico.

  15. NO/sub x/ removal facility: MON process

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Y

    1974-05-01

    A newly developed process for nitrogen oxides removal is described. The MON process, named for Mitsubishi Kizoku, Okabe of Tohoku Univ., and Nippon Kagaku, uses potassium permanganate as an oxidizing agent. Potassium permanganate in alkaline solution converts nitric oxide into nitrate and nitrogen dioxide into nitric acid. The resulting MnO/sub 2/ is easily filtered and recovered as material for the manufacturing of KMnO/sub 4/. Contrary to the conventional methods, the NO/sub x/ conversion rate increases with increasing temperature. Test results at a pilot plant showed that NO/sub x/ was reduced from 570 ppM (nitric oxide 520 ppM) to 27 ppM (mostly NO) at 97 to 98 percent conversion. Another advantage of the process is that other acidic gases such as sulfur dioxide are also removed.

  16. Food processing using electrons and X-rays

    International Nuclear Information System (INIS)

    Clouston, J.G.

    1985-01-01

    The ionizing radiation which will be used as process energy for the preservation of food, will be limited to high energy electrons (less than 10 MeV), X-rays (less than 5 MeV) and gamma rays emitted by cobalt-60 (1.17;1.33 MeV) and cesium -137 (0.663 MeV). When a foodstuff is irradiated with any of these radiations absorption of the radiant energy will initiate a variety of reactions between its atomic and molecular constituents causing permanent chemical, physical and biological changes. This paper focusses on radiation processing using electron or X-ray generators in the range 2 to 10 MeV

  17. Rare processes with top quarks: FCNCs, tt+X, tttt, t+X

    CERN Document Server

    Li, Yichen; The ATLAS collaboration

    2018-01-01

    The latest ATLAS and CMS searches or measurements of rare processes with top quarks, including FCNCs, tt+X, tttt, and t+X, are presented. FCNC branching ratio limits are pushed to new low, with some of them even reaching the expected limits for some BSMs. Associated production of W/Z/photon with a pair of top quarks are established and their cross sections are measured. The evidence of associated production of Z boson with a top quark is found. While there is no evidence for the four top quark production yet.

  18. Thermal analysis on x-ray tube for exhaust process

    Science.gov (United States)

    Kumar, Rakesh; Rao Ratnala, Srinivas; Veeresh Kumar, G. B.; Shivakumar Gouda, P. S.

    2018-02-01

    It is great importance in the use of X-rays for medical purposes that the dose given to both the patient and the operator is carefully controlled. There are many types of the X- ray tubes used for different applications based on their capacity and power supplied. In present thesis maxi ray 165 tube is analysed for thermal exhaust processes with ±5% accuracy. Exhaust process is usually done to remove all the air particles and to degasify the insert under high vacuum at 2e-05Torr. The tube glass is made up of Pyrex material, 95%Tungsten and 5%rhenium is used as target material for which the melting point temperature is 3350°C. Various materials are used for various parts; during the operation of X- ray tube these waste gases are released due to high temperature which in turn disturbs the flow of electrons. Thus, before using the X-ray tube for practical applications it has to undergo exhaust processes. Initially we build MX 165 model to carry out thermal analysis, and then we simulate the bearing temperature profiles with FE model to match with test results with ±5%accuracy. At last implement the critical protocols required for manufacturing processes like MF Heating, E-beam, Seasoning and FT.

  19. Limitations of retarded (bisulfite) x-ray film processing

    International Nuclear Information System (INIS)

    Stoering, J.P.; Dittmore, C.

    1979-01-01

    We demonstrate the limitations of using retarded (bisulfite) developer to abate film sensitivity of x-ray films that have been exposed to intense radiation. We compared the measured densities of a large number of Kodak Type-M x-ray film samples exposed to a known fluence of monochromatic x-rays. These film samples were processed in three separate batches of bisulfite developer mixed in the same proportions. We concluded that reproducible film-density information cannot be obtained using different batches of (bisulfite) developer solutions

  20. Development of X-ray radiography examination technology by image processing method

    Energy Technology Data Exchange (ETDEWEB)

    Min, Duck Kee; Koo, Dae Seo; Kim, Eun Ka [Korea Atomic Energy Research Institute, Taejon (Korea)

    1998-06-01

    Because the dimension of nuclear fuel rods was measured with rapidity and accuracy by X-ray radiography examination, the set-up of image processing system which was composed of 979 CCD-L camera, image processing card and fluorescent lighting was carried out, and the image processing system enabled image processing to perform. The examination technology of X-ray radiography, which enabled dimension measurement of nuclear fuel rods to perform, was developed by image processing method. The result of dimension measurement of standard fuel rod by image processing method was 2% reduction in relative measuring error than that of X-ray radiography film, while the former was better by 100 {approx} 200 {mu}m in measuring accuracy than the latter. (author). 9 refs., 22 figs., 3 tabs.

  1. Event processing in X-IFU detector onboard Athena.

    Science.gov (United States)

    Ceballos, M. T.; Cobos, B.; van der Kuurs, J.; Fraga-Encinas, R.

    2015-05-01

    The X-ray Observatory ATHENA was proposed in April 2014 as the mission to implement the science theme "The Hot and Energetic Universe" selected by ESA for L2 (the second Large-class mission in ESA's Cosmic Vision science programme). One of the two X-ray detectors designed to be onboard ATHENA is X-IFU, a cryogenic microcalorimeter based on Transition Edge Sensor (TES) technology that will provide spatially resolved high-resolution spectroscopy. X-IFU will be developed by a consortium of European research institutions currently from France (leadership), Italy, The Netherlands, Belgium, UK, Germany and Spain. From Spain, IFCA (CSIC-UC) is involved in the Digital Readout Electronics (DRE) unit of the X-IFU detector, in particular in the Event Processor Subsytem. We at IFCA are in charge of the development and implementation in the DRE unit of the Event Processing algorithms, designed to recognize, from a noisy signal, the intensity pulses generated by the absorption of the X-ray photons, and lately extract their main parameters (coordinates, energy, arrival time, grade, etc.) Here we will present the design and performance of the algorithms developed for the event recognition (adjusted derivative), and pulse grading/qualification as well as the progress in the algorithms designed to extract the energy content of the pulses (pulse optimal filtering). IFCA will finally have the responsibility of the implementation on board in the (TBD) FPGAs or micro-processors of the DRE unit, where this Event Processing part will take place, to fit into the limited telemetry of the instrument.

  2. Sulphursoil - Delano Development Corporation

    Energy Technology Data Exchange (ETDEWEB)

    None

    1985-06-01

    A sizable amount of technical information has been accumulated on the effects of agricultural applications of the natural mineral product called Sul-Fe. This technical information supports the field observations of farmers, landscapers and gardeners who have used the product. Sul-Fe is often evaluated in terms of its sulphur content alone. When compared to elemental sulphur (100% sulphur), the 18 to 21% sulphur content of Sul-Fe seems relatively low. However, as the following technical data indicates, when judged on actual effects, Sul-Fe's complex mixture of minerals has several advantages over elemental sulphur. When judged on the basis of soil acidulation, Sul-Fe has more immediate effects than elemental sulphur. The rapid acidifying effect is due to Sul-Fe's content of crystalline sulphuric acid. Sul-Fe also has long-term effects on soil pH due to its content of sulphur and sulfides and the time required to oxidize these materials. Elemental sulphur contains sulphur in only one chemical form which must be microbially oxidized before it becomes reactive in the soil solution, a reaction that takes quite some time in some soils. Sul-Fe is thus better than elemental sulphur in terms of immediate effects and comparable in terms of long term effects. Applied blends of Sul-Fe supplemented with elemental sulphur may provide for a maximization of both short and long term effects. An additional benefit derived from the use of Sul-Fe is the addition to the soil of a variety of trace nutrients including iron, calcium, zinc, copper, manganese, magnesium, and molybdenum.

  3. Image processing techniques for thermal, x-rays and nuclear radiations

    International Nuclear Information System (INIS)

    Chadda, V.K.

    1998-01-01

    The paper describes image acquisition techniques for the non-visible range of electromagnetic spectrum especially thermal, x-rays and nuclear radiations. Thermal imaging systems are valuable tools used for applications ranging from PCB inspection, hot spot studies, fire identification, satellite imaging to defense applications. Penetrating radiations like x-rays and gamma rays are used in NDT, baggage inspection, CAT scan, cardiology, radiography, nuclear medicine etc. Neutron radiography compliments conventional x-rays and gamma radiography. For these applications, image processing and computed tomography are employed for 2-D and 3-D image interpretation respectively. The paper also covers main features of image processing systems for quantitative evaluation of gray level and binary images. (author)

  4. J-2X Test Articles Using FDM Process

    Science.gov (United States)

    Anderson, Ted; Ruf, Joe; Steele, Phil

    2010-01-01

    This viewgraph presentation gives a brief history of the J-2X engine, along with detailed description of the material demonstrator and test articles that were created using Fused Deposition Modeling (FDM) process.

  5. Turbines. NO{sub x} processing on Solar gas turbines; Turbines. Traitement des NO{sub x} sur les turbines a gaz solar

    Energy Technology Data Exchange (ETDEWEB)

    Chausse, X. [Spie-Trindel, 95 - Cergy (France)

    1997-12-31

    This paper presents the SoLoNOx process developed by the Solar Turbines Incorporated company for the prevention of NO{sub x} production in his gas turbines. The formation of combustion products, by-products and NO{sub x} are recalled first and then the different existing processes for the reduction of pollutants are reviewed: water or steam injection, and purification of exhaust gases. The SoLoNOx process uses a dry, weak and pre-mixed mixture and allows better NO{sub x} and CO reductions than the water injection process. (J.S.)

  6. Problems with film processing in medical X-ray imaging in Lithuania

    International Nuclear Information System (INIS)

    Sniureviciute, M.; Adliene, D.

    2005-01-01

    Optimisation in X-ray imaging in order to reduce patient doses during diagnostic X-ray examinations is a complex process given the high level of image quality required. When quality systems are implemented as a basis for optimisation, attention should be paid to the qualifications of the staff and quality control of the equipment and of the X-ray imaging procedures, as well as to the methods used to evaluate the quality of these procedures. Until recently, quality control procedures at health care institutions in Lithuania were limited to the testing of X-ray units. Since film processing is one of the most important factors influencing patient doses and image quality during X-ray examinations, in 2003 the Kaunas department of the Radiation Protection Centre organised inspections of film processing laboratories in 11 health care institutions - hospitals and outpatient departments - in the Kaunas region. Problems of non-compliance with requirements identified during these inspections are discussed in this paper. Most of the health care institutions inspected already had quality assurance programmes. However, the implementation of these programmes was sometimes erratic because of the insufficient attention paid to the film developing processes. The worst situation was found in 4 institutions where the films were developed manually. Only 3 of the 11 departments inspected had sensitometers and densitometers for quality control of the processing. In many cases there was no control of chemicals, film sensitivity and density, or else control was irregular. In only a few departments were the effects of repeated controls investigated and discussed. Despite the current problems occurring in medical X-ray diagnostic departments in Lithuania, the situation is rapidly improving. New equipment is being installed, new devices for quality control are being used and, last but not least, the view of hospital administrators, radiologists and laboratory workers towards quality

  7. Higher-order processes in x-ray photoionization of atoms

    International Nuclear Information System (INIS)

    Kanter, E. P.; Dunford, R. W.; Krassig, B.; Southworth, S. H.; Young, L.

    2006-01-01

    There are several fourth-generation X-ray light source projects now underway around the world and it is anticipated that by the end of the decade, one or more of these X-ray free-electron lasers will be operational. In this contribution, we describe recent measurements and future plans to study both multielectron and multiphoton atomic photoionization. Although such higher-order processes are rare with present third-generation sources, they will be commonplace in experimental work with the new sources. The topics we discuss here are double K-shell ionization and two-photon X-ray photoionization

  8. Powder metallurgical processing of functionally graded p-Pb1-x Sn x Te materials for thermoelectric applications

    International Nuclear Information System (INIS)

    Gelbstein, Y.; Dashevsky, Z.; Dariel, M.P.

    2007-01-01

    Lead tin telluride-based compounds are p-type materials for thermoelectric applications, in the 50-600 deg. C temperature range. The electronic transport properties of PbTe and Pb 1- x Sn x Te materials are strongly dependent on the processing approach. Powder metallurgy is a suitable approach for the preparation of Functionally graded materials (FGMs) but its effects on the electronic properties have to be carefully checked. Powder metallurgical processing may introduce atomic defects and local strains into the material and, thereby, alter the carrier concentration. Such material may be in non-equilibrium conditions at the operating temperature with unstable thermoelectric properties. This effect can be reduced and eliminated by appropriate annealing procedures. In FGMs, annealing up to the stabilization of the thermoelectric properties is mandatory for achieving the desired carrier concentration profile along the sample. The design procedures of the FGMs, as well as the annealing effects on cold compacted and sintered Pb 1- x Sn x Te samples are described in details

  9. X-ray scattering studies of non-equilibrium ordering processes

    International Nuclear Information System (INIS)

    Nagler, S.E.

    1990-01-01

    We report on the progress of our project entitled ''X-ray Scattering of Non-Equilibrium Ordering Processes.'' During the past year we have made the first synchrotron measurements of ordering in Cu 3 Au have revealed the presence of an intermediate, non-equilibrium ordered state. Preliminary work involving x-ray magnetic scattering has been carried out. Work is continuing in these areas as well as on related problems. 5 refs

  10. MMX-I: data-processing software for multimodal X-ray imaging and tomography

    Energy Technology Data Exchange (ETDEWEB)

    Bergamaschi, Antoine, E-mail: antoine.bergamaschi@synchrotron-soleil.fr; Medjoubi, Kadda [Synchrotron SOLEIL, BP 48, Saint-Aubin, 91192 Gif sur Yvette (France); Messaoudi, Cédric; Marco, Sergio [Université Paris-Saclay, CNRS, Université Paris-Saclay, F-91405 Orsay (France); Institut Curie, INSERM, PSL Reseach University, F-91405 Orsay (France); Somogyi, Andrea [Synchrotron SOLEIL, BP 48, Saint-Aubin, 91192 Gif sur Yvette (France)

    2016-04-12

    The MMX-I open-source software has been developed for processing and reconstruction of large multimodal X-ray imaging and tomography datasets. The recent version of MMX-I is optimized for scanning X-ray fluorescence, phase-, absorption- and dark-field contrast techniques. This, together with its implementation in Java, makes MMX-I a versatile and friendly user tool for X-ray imaging. A new multi-platform freeware has been developed for the processing and reconstruction of scanning multi-technique X-ray imaging and tomography datasets. The software platform aims to treat different scanning imaging techniques: X-ray fluorescence, phase, absorption and dark field and any of their combinations, thus providing an easy-to-use data processing tool for the X-ray imaging user community. A dedicated data input stream copes with the input and management of large datasets (several hundred GB) collected during a typical multi-technique fast scan at the Nanoscopium beamline and even on a standard PC. To the authors’ knowledge, this is the first software tool that aims at treating all of the modalities of scanning multi-technique imaging and tomography experiments.

  11. Melt-spin processing of YBa2Cu3O7-x

    International Nuclear Information System (INIS)

    Folkerts, T.J.; Kramer, M.J.; McCallum, R.W.; Iowa State Univ. of Science and Technology, Ames, IA

    1991-01-01

    We introduce a novel containerless melt-spin processing technique for YBa 2 Cu 3 O 7-x using prereacted oxide powders which are rapidly melted and subsequentially quenched in a controlled atmosphere. This results in flakes with typical dimensions of 3000x150x15 μm 3 . Powder XRD indicates that all samples contain Y 2 O 3 , but that the Ba--Cu--O phases present depend on the processing parameters. SEM and TEM studies show these phases are finely dispersed: the typical grain size for Y 2 O 3 is 1--2 μm, and for the Ba--Cu--O phases it is <0.5 μm

  12. Operação periódica de um leito gotejante de carvão ativado para redução da emissão do poluente atmosférico SO2 com geração de ácido sulfúrico.

    OpenAIRE

    Sandro Megale Pizzo

    2003-01-01

    O desempenho dos modos periódico e contínuo de operação para o tratamento de uma mistura gasosa de SO2 em ar foi analisado utilizando-se um reator de aço inox, em escala de bancada de 77,92mm de diâmetro interno, contendo leito fixo de carvão ativado de 80,00mm de altura, com partículas de 2,00 a 2,36mm. Foram obtidas as eficiências médias de remoção do gás e as concentrações de ácido sulfúrico produzido nas soluções líquidas de saída, em função da concentração inicial de SO2 (500, 1.000 e 1....

  13. The x rescaling parameter' formula of the extended x rescaling model and the nuclear effect l-A DIS process

    International Nuclear Information System (INIS)

    Gao Yonghua; He Mingzhong; Duan Chungui

    2003-01-01

    The authors present an x rescaling parameters' formula for partons in the extended x rescaling model, where we have established the connection between the rescaling parameter and the mean binding energy. Using x rescaling parameters obtained by the x rescaling parameters' formula, we calculate the average nucleon structure function ratio of DIS process in l-A (Al, Ca, Pb) collision to l-C collision respectively. The result is in good agreement with experimental data

  14. Quality control procedure for dental x-ray film processing

    International Nuclear Information System (INIS)

    Tingey, D.R.C.

    1983-08-01

    Methods of obtaining the optimum processing from dental films are discussed. A method of quality control of developing conditions for dental x-ray films has been developed. It is relatively easy to maintain and is sufficiently accurate for practical purposes

  15. A targeted glycan-related gene screen reveals heparan sulfate proteoglycan sulfation regulates WNT and BMP trans-synaptic signaling.

    Directory of Open Access Journals (Sweden)

    Neil Dani

    Full Text Available A Drosophila transgenic RNAi screen targeting the glycan genome, including all N/O/GAG-glycan biosynthesis/modification enzymes and glycan-binding lectins, was conducted to discover novel glycan functions in synaptogenesis. As proof-of-product, we characterized functionally paired heparan sulfate (HS 6-O-sulfotransferase (hs6st and sulfatase (sulf1, which bidirectionally control HS proteoglycan (HSPG sulfation. RNAi knockdown of hs6st and sulf1 causes opposite effects on functional synapse development, with decreased (hs6st and increased (sulf1 neurotransmission strength confirmed in null mutants. HSPG co-receptors for WNT and BMP intercellular signaling, Dally-like Protein and Syndecan, are differentially misregulated in the synaptomatrix of these mutants. Consistently, hs6st and sulf1 nulls differentially elevate both WNT (Wingless; Wg and BMP (Glass Bottom Boat; Gbb ligand abundance in the synaptomatrix. Anterograde Wg signaling via Wg receptor dFrizzled2 C-terminus nuclear import and retrograde Gbb signaling via synaptic MAD phosphorylation and nuclear import are differentially activated in hs6st and sulf1 mutants. Consequently, transcriptional control of presynaptic glutamate release machinery and postsynaptic glutamate receptors is bidirectionally altered in hs6st and sulf1 mutants, explaining the bidirectional change in synaptic functional strength. Genetic correction of the altered WNT/BMP signaling restores normal synaptic development in both mutant conditions, proving that altered trans-synaptic signaling causes functional differentiation defects.

  16. Triggering photochemical processes in frozen extraterrestrial worlds by soft X-rays

    International Nuclear Information System (INIS)

    Pilling, Sergio; Bergantini, Alexandre; Vasconcelos, Fredson A; Rocha, Will R M

    2015-01-01

    We presents and experimental investigation on the effects produced by broad band soft X-rays (combined with a small fraction of vacuum ultra violet photons and possibly secondary elec-trons) on the surface of three moons of giant planets: Europa, Titan and Enceladus. Such environ-ments are constantly exposed to space ionizing agents (UV and soft X-rays photons, electrons and ions) allowing photodissociation processes, surface photochemistry and prebiotic chemistry. The processing of such spatial ices have promoted an enhancement in the chemical complexity, similar what may have happened in the early earth triggering the arising of life. (paper)

  17. Process strategies for ultra-deep x-ray lithography at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Mancini, D.C.; Moldovan, N.; Divan, R.; De Carlo, F.; Yaeger, J.

    2001-01-01

    For the past five years, we have been investigating and advancing processing capabilities for deep x-ray lithography (DXRL) using synchrotron radiation from a bending magnet at the Advanced Photon Source (APS), with an emphasis on ultra-deep structures (1mm to 1cm thick). The use of higher-energy x-rays has presented many challenges in developing optimal lithographic techniques for high-aspect ratio structures: mask requirements, resist preparation, exposure, development, and post-processing. Many problems are more severe for high-energy exposure of thicker films than for sub-millimeter structures and affect resolution, processing time, adhesion, damage, and residue. A number of strategies have been created to overcome the challenges and limitations of ultra-deep x-ray lithography (UDXRL), that have resulted in the current choices for mask, substrate, and process flow at the APS. We describe our current process strategies for UDXRL, how they address the challenges presented, and their current limitations. We note especially the importance of the process parameters for use of the positive tone resist PMMA for UDXRL, and compare to the use of negative tone resists such as SU-8 regarding throughput, resolution, adhesion, damage, and post-processing.

  18. Quality control of diagnostic x-ray equipment and film processing

    International Nuclear Information System (INIS)

    1993-01-01

    According to the section 40 of the Radiation Act (592/92), the licensee is required in Finland to make the arrangements to control the function of the radiation equipment and related facilities used for medical procedures. The guide explains how quality control can be organized for diagnostic x-ray equipment. It also gives recommendations for constancy tests for conventional x-ray radiographic and fluoroscopic equipment and for film processing. The recommendations are based on the publications and statements of the International Committee for Radiation Protection (ICRP) and standardization organizations. The intention is that the operators of x-ray equipment or the maintenance personnel are able to perform the quality control tests presented in the guide

  19. MMX-I: data-processing software for multimodal X-ray imaging and tomography.

    Science.gov (United States)

    Bergamaschi, Antoine; Medjoubi, Kadda; Messaoudi, Cédric; Marco, Sergio; Somogyi, Andrea

    2016-05-01

    A new multi-platform freeware has been developed for the processing and reconstruction of scanning multi-technique X-ray imaging and tomography datasets. The software platform aims to treat different scanning imaging techniques: X-ray fluorescence, phase, absorption and dark field and any of their combinations, thus providing an easy-to-use data processing tool for the X-ray imaging user community. A dedicated data input stream copes with the input and management of large datasets (several hundred GB) collected during a typical multi-technique fast scan at the Nanoscopium beamline and even on a standard PC. To the authors' knowledge, this is the first software tool that aims at treating all of the modalities of scanning multi-technique imaging and tomography experiments.

  20. X-Window for process control in a mixed hardware environment

    International Nuclear Information System (INIS)

    Clausen, M.; Rehlich, K.

    1992-01-01

    X-Window is a common standard for display purposes on the current workstations. The possibility to create more than one window on a single screen enables the operators to gain more information about the process. Multiple windows from different control systems using mixed hardware is one of the problems this paper will describe. The experience shows that X-Window is a standard per definition, but not in any case. But it is an excellent tool to separate data-acquisition and display from each other over long distances using different types of hardware and software for communications and display. Our experience with X-Window displays for the cryogenic control system and the vacuum control system at HERA on DEC and SUN hardware will be described. (author)

  1. Numerical simulation of X90 UOE pipe forming process

    Science.gov (United States)

    Zou, Tianxia; Ren, Qiang; Peng, Yinghong; Li, Dayong; Tang, Ding; Han, Jianzeng; Li, Xinwen; Wang, Xiaoxiu

    2013-12-01

    The UOE process is an important technique to manufacture large-diameter welding pipes which are increasingly applied in oil pipelines and offshore platforms. The forming process of UOE mainly consists of five successive operations: crimping, U-forming, O-forming, welding and mechanical expansion, through which a blank is formed into a pipe in a UOE pipe mill. The blank with an appropriate edge bevel is bent into a cylindrical shape by crimping (C-forming), U-forming and O-forming successively. After the O-forming, there is an open-seam between two ends of the plate. Then, the blank is welded by automatic four-electrode submerged arc welding technique. Subsequently, the welded pipe is expanded with a mechanical expander to get a high precision circular shape. The multiple operations in the UOE mill make it difficult to control the quality of the formed pipe. Therefore, process design mainly relies on experience in practical production. In this study, the UOE forming of an API X90 pipe is studied by using finite element simulation. The mechanical properties tests are performed on the API X90 pipeline steel blank. A two-dimensional finite element model under the hypothesis of plane strain condition is developed to simulate the UOE process according to data coming from the workshop. A kinematic hardening model is used in the simulation to take the Bauschinger effect into account. The deformation characteristics of the blank during the forming processes are analyzed. The simulation results show a significant coherence in the geometric configurations comparing with the practical manufacturing.

  2. Image processing for x-ray inspection of pistachio nuts

    Science.gov (United States)

    Casasent, David P.

    2001-03-01

    A review is provided of image processing techniques that have been applied to the inspection of pistachio nuts using X-ray images. X-ray sensors provide non-destructive internal product detail not available from other sensors. The primary concern in this data is detecting the presence of worm infestations in nuts, since they have been linked to the presence of aflatoxin. We describe new techniques for segmentation, feature selection, selection of product categories (clusters), classifier design, etc. Specific novel results include: a new segmentation algorithm to produce images of isolated product items; preferable classifier operation (the classifier with the best probability of correct recognition Pc is not best); higher-order discrimination information is present in standard features (thus, high-order features appear useful); classifiers that use new cluster categories of samples achieve improved performance. Results are presented for X-ray images of pistachio nuts; however, all techniques have use in other product inspection applications.

  3. The MicroAnalysis Toolkit: X-ray Fluorescence Image Processing Software

    International Nuclear Information System (INIS)

    Webb, S. M.

    2011-01-01

    The MicroAnalysis Toolkit is an analysis suite designed for the processing of x-ray fluorescence microprobe data. The program contains a wide variety of analysis tools, including image maps, correlation plots, simple image math, image filtering, multiple energy image fitting, semi-quantitative elemental analysis, x-ray fluorescence spectrum analysis, principle component analysis, and tomographic reconstructions. To be as widely useful as possible, data formats from many synchrotron sources can be read by the program with more formats available by request. An overview of the most common features will be presented.

  4. Trends in the electronic X-ray image formation and processing

    International Nuclear Information System (INIS)

    Meyer-Ebrecht, D.; Spiesberger, W.

    1976-01-01

    A report is given on the technological progress in components for the electronic imaging and reproduction in X-ray diagnostics which could enable the partial replacement of radiophotography. Furthermore, electronic post processing methods, in particular in tomography, are reviewed. (ORU) [de

  5. Data processing software suite SITENNO for coherent X-ray diffraction imaging using the X-ray free-electron laser SACLA

    International Nuclear Information System (INIS)

    Sekiguchi, Yuki; Oroguchi, Tomotaka; Takayama, Yuki; Nakasako, Masayoshi

    2014-01-01

    The software suite SITENNO is developed for processing diffraction data collected in coherent X-ray diffraction imaging experiments of non-crystalline particles using an X-ray free-electron laser. Coherent X-ray diffraction imaging is a promising technique for visualizing the structures of non-crystalline particles with dimensions of micrometers to sub-micrometers. Recently, X-ray free-electron laser sources have enabled efficient experiments in the ‘diffraction before destruction’ scheme. Diffraction experiments have been conducted at SPring-8 Angstrom Compact free-electron LAser (SACLA) using the custom-made diffraction apparatus KOTOBUKI-1 and two multiport CCD detectors. In the experiments, ten thousands of single-shot diffraction patterns can be collected within several hours. Then, diffraction patterns with significant levels of intensity suitable for structural analysis must be found, direct-beam positions in diffraction patterns determined, diffraction patterns from the two CCD detectors merged, and phase-retrieval calculations for structural analyses performed. A software suite named SITENNO has been developed to semi-automatically apply the four-step processing to a huge number of diffraction data. Here, details of the algorithm used in the suite are described and the performance for approximately 9000 diffraction patterns collected from cuboid-shaped copper oxide particles reported. Using the SITENNO suite, it is possible to conduct experiments with data processing immediately after the data collection, and to characterize the size distribution and internal structures of the non-crystalline particles

  6. The software development process at the Chandra X-ray Center

    Science.gov (United States)

    Evans, Janet D.; Evans, Ian N.; Fabbiano, Giuseppina

    2008-08-01

    Software development for the Chandra X-ray Center Data System began in the mid 1990's, and the waterfall model of development was mandated by our documents. Although we initially tried this approach, we found that a process with elements of the spiral model worked better in our science-based environment. High-level science requirements are usually established by scientists, and provided to the software development group. We follow with review and refinement of those requirements prior to the design phase. Design reviews are conducted for substantial projects within the development team, and include scientists whenever appropriate. Development follows agreed upon schedules that include several internal releases of the task before completion. Feedback from science testing early in the process helps to identify and resolve misunderstandings present in the detailed requirements, and allows review of intangible requirements. The development process includes specific testing of requirements, developer and user documentation, and support after deployment to operations or to users. We discuss the process we follow at the Chandra X-ray Center (CXC) to develop software and support operations. We review the role of the science and development staff from conception to release of software, and some lessons learned from managing CXC software development for over a decade.

  7. Processing two-dimensional X-ray diffraction and small-angle scattering data in DAWN 2.

    Science.gov (United States)

    Filik, J; Ashton, A W; Chang, P C Y; Chater, P A; Day, S J; Drakopoulos, M; Gerring, M W; Hart, M L; Magdysyuk, O V; Michalik, S; Smith, A; Tang, C C; Terrill, N J; Wharmby, M T; Wilhelm, H

    2017-06-01

    A software package for the calibration and processing of powder X-ray diffraction and small-angle X-ray scattering data is presented. It provides a multitude of data processing and visualization tools as well as a command-line scripting interface for on-the-fly processing and the incorporation of complex data treatment tasks. Customizable processing chains permit the execution of many data processing steps to convert a single image or a batch of raw two-dimensional data into meaningful data and one-dimensional diffractograms. The processed data files contain the full data provenance of each process applied to the data. The calibration routines can run automatically even for high energies and also for large detector tilt angles. Some of the functionalities are highlighted by specific use cases.

  8. Soft-X-Ray Projection Lithography Using a High-Repetition-Rate Laser-Induced X-Ray Source for Sub-100 Nanometer Lithography Processes

    NARCIS (Netherlands)

    E. Louis,; F. Bijkerk,; Shmaenok, L.; Voorma, H. J.; van der Wiel, M. J.; Schlatmann, R.; Verhoeven, J.; van der Drift, E. W. J. M.; Romijn, J.; Rousseeuw, B. A. C.; Voss, F.; Desor, R.; Nikolaus, B.

    1993-01-01

    In this paper we present the status of a joint development programme on soft x-ray projection lithography (SXPL) integrating work on high brightness laser plasma sources. fabrication of multilayer x-ray mirrors. and patterning of reflection masks. We are in the process of optimization of a

  9. Compact x-ray microradiograph for in situ imaging of solidification processes: Bringing in situ x-ray micro-imaging from the synchrotron to the laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Rakete, C.; Baumbach, C.; Goldschmidt, A.; Samberg, D.; Schroer, C. G. [Institut fuer Strukturphysik, Technische Universitaet Dresden, D-01062 Dresden (Germany); Breede, F.; Stenzel, C. [Astrium-Space Transportation, Department: TO 611, Claude-Dornier-Strasse, D-88039 Friedrichshafen (Germany); Zimmermann, G.; Pickmann, C. [ACCESS e.V., Intzestrasse 5, D-52072 Aachen (Germany); Houltz, Y.; Lockowandt, C. [Science Services Division, SSC, Box 4207, SE-17104 Solna (Sweden); Svenonius, O.; Wiklund, P. [Scint-X AB, Torshamnsgatan 35, SE-164 40 Kista (Sweden); Mathiesen, R. H. [Inst. for Fysikk, NTNU, N-7491 Trondheim (Norway)

    2011-10-15

    A laboratory based high resolution x-ray radiograph was developed for the investigation of solidification dynamics in alloys. It is based on a low-power microfocus x-ray tube and is potentially appropriate for x-ray diagnostics in space. The x-ray microscope offers a high spatial resolution down to approximately 5 {mu}m. Dynamic processes can be resolved with a frequency of up to 6 Hz. In reference experiments, the setup was optimized to yield a high contrast for AlCu-alloys. With samples of about 150 {mu}m thickness, high quality image sequences of the solidification process were obtained with high resolution in time and space.

  10. Microscopic theory of magnetization processes in Y (Co sub 1 sub - sub x Al sub x) sub 2

    CERN Document Server

    Khmelevskyi, S; Mohn, P

    2002-01-01

    Employing ab initio electronic structure calculations we study the development of the magnetic properties in Y (Co sub 1 sub - sub x Al sub x) sub 2 for varying Al concentration. The effect of substitutional disorder is treated in the coherent-potential approximation implemented within a tight-binding linear muffin-tin orbital method. The experimentally observed reduction of the critical field of the itinerant electron metamagnetic phase transition with increasing content of non-magnetic Al is explained. It is shown, on the basis of a T = 0 K Stoner type itinerant magnetism theory, that the alloying-induced changes in the shape of the calculated density of states, caused by the Al substitution, lead to (i) a stabilization of the magnetic state, (ii) a smoothening of the first-order metamagnetic transition and (iii) a subsequent suppression of the metamagnetic transition around x 0.15. Analysing the magnetization processes in Y (Co sub 1 sub - sub x Al sub x) sub 2 by varying the strength of the exchange inter...

  11. Moessbauer investigation of Sm{sub 2}Fe{sub 17-x}Ga{sub x} powders at different steps of the HDDR process

    Energy Technology Data Exchange (ETDEWEB)

    Steyaert, S.; Breton, J.-M. le; Teillet, J. [Rouen Univ. (France). Groupe de Metall. Phys.; Kubis, M.; Handstein, A.; Mueller, K.H. [Rouen Univ. (France). Groupe de Metall. Phys.]|[Institut fuer Festkoerper- und Werkstofforschung Dresden e.V. (Germany). Inst. fuer Metallische Werkstoffe

    1998-07-01

    Sm{sub 2}Fe{sub 17-x}Ga{sub x} powders (x=0,0.5,1,2) obtained at different steps of the HDDR process were analysed by Moessbauer spectrometry. For the homogenised powders, the mean hyperfine field of the Sm{sub 2}Fe{sub 17-x}Ga{sub x} contribution increases with Ga content in agreement with a lattice expansion. The anisotropy change from planar to uniaxial is confirmed in samples with x = 2. In the hydrogenated powders, the value of the mean hyperfine field of Sm{sub 2}Fe{sub 17-x}Ga{sub x}H{sub y} is greater than that of Sm{sub 2}Fe{sub 17-x}Ga{sub x} in the corresponding homogenised powders, in agreement with the presence of hydrogen in the 2:17 structure. It decreases with increasing Ga amount, suggesting that the H content in the Sm{sub 2}Fe{sub 17-x}Ga{sub x}H{sub y} phase decreases with increasing Ga content. In the disproportionated powders, the disproportionation reaction is incomplete for x {>=} 1 as the contributions of both the Sm{sub 2}Fe{sub 17-x}Ga{sub x}H{sub y} and {alpha}-Fe(Ga) phases are observed in the corresponding Moessbauer spectra. This indicates that for x {>=} 1 the hydrogen diffusion is inhibited during hydrogenation. (orig.)

  12. Ultra fast atomic process in X-ray emission by inner-shell ionization

    Energy Technology Data Exchange (ETDEWEB)

    Moribayashi, Kengo; Sasaki, Akira [Japan Atomic Energy Research Inst., Neyagawa, Osaka (Japan). Kansai Research Establishment; Tajima, T

    1998-03-01

    An ultra-fast atomic process together with X-ray emission by inner-shell ionization using high intensity (10{sup 18} W/cm{sup 2}) short pulse (20fs) X-ray is studied. A new class of experiment is proposed and a useful pumping source is suggested. In this method, it is found that the gain value of X-ray laser amounts to larger than 1000(1/cm) with use of the density of 10{sup 22}/cm{sup 3} of carbon atom. Electron impact ionization effect and initial density effect as well as intensity of pumping source effect are also discussed. (author)

  13. X-ray image processing software for computing object size and object location coordinates from acquired optical and x-ray images

    International Nuclear Information System (INIS)

    Tiwari, Akash; Tiwari, Shyam Sunder; Tiwari, Railesha; Panday, Lokesh; Panday, Jeet; Suri, Nitin

    2004-01-01

    X-ray and Visible image data processing software has been developed in Visual Basic for real time online and offline image information processing for NDT and Medical Applications. Software computes two dimension image size parameters from its sharp boundary lines by raster scanning the image contrast data. Code accepts bit map image data and hunts for multiple tumors of different sizes that may be present in the image definition and then computes size of each tumor and locates its approximate center for registering its location coordinates. Presence of foreign metal and glass balls industrial product such as chocolate and other food items imaged out using x-ray imaging technique are detected by the software and their size and position co-ordinates are computed by the software. Paper discusses ways and means to compute size and coordinated of air bubble like objects present in the x-ray and optical images and their multiple existences in image of interest. (author)

  14. Simple solution-processed CuO{sub X} as anode buffer layer for efficient organic solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Wenfei [CAS Key Laboratory of Bio-based Materials, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, 189 Songling Road, Qingdao 266101 (China); Institute of Hybrid Materials, The Growing Base for State Key Laboratory, Qingdao University, 308 Ningxia Road, Qingdao 266071 (China); Yang, Chunpeng [CAS Key Laboratory of Bio-based Materials, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, 189 Songling Road, Qingdao 266101 (China); Bao, Xichang, E-mail: baoxc@qibebt.ac.cn [CAS Key Laboratory of Bio-based Materials, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, 189 Songling Road, Qingdao 266101 (China); Sun, Liang; Wang, Ning [CAS Key Laboratory of Bio-based Materials, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, 189 Songling Road, Qingdao 266101 (China); Tang, Jianguo [Institute of Hybrid Materials, The Growing Base for State Key Laboratory, Qingdao University, 308 Ningxia Road, Qingdao 266071 (China); Chen, Weichao [CAS Key Laboratory of Bio-based Materials, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, 189 Songling Road, Qingdao 266101 (China); Yang, Renqiang, E-mail: yangrq@qibebt.ac.cn [CAS Key Laboratory of Bio-based Materials, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, 189 Songling Road, Qingdao 266101 (China)

    2015-10-15

    Graphical abstract: - Highlights: • Simple solution-processed CuO{sub X} hole transport layer for efficient organic solar cell. • Good photovoltaic performances as hole transport layer in OSCs with P3HT and PBDTTT-C as donor materials. • The device with CuO{sub X} as hole transport layer shows great improved stability compared with that of device with PEDOT:PSS as hole transport layer. - Abstract: A simple, solution-processed ultrathin CuO{sub X} anode buffer layer was fabricated for high performance organic solar cells (OSCs). XPS measurement demonstrated that the CuO{sub X} was the composite of CuO and Cu{sub 2}O. The CuO{sub X} modified ITO glass exhibit a better surface contact with the active layer. The photovoltaic performance of the devices with CuO{sub X} layer was optimized by varying the thickness of CuO{sub X} films through changing solution concentration. With P3HT:PC{sub 61}BM as the active layer, we demonstrated an enhanced PCE of 4.14% with CuO{sub X} anode buffer layer, compared with that of PEDOT:PSS layer. The CuO{sub X} layer also exhibits efficient photovoltaic performance in devices with PBDTTT-C:PC{sub 71}BM as the active layer. The long-term stability of CuO{sub X} device is better than that of PEDOT:PSS device. The results indicate that the easy solution-processed CuO{sub X} film can act as an efficient anode buffer layer for high-efficiency OSCs.

  15. X-ray and DSC studies on the melt-recrystallization process of poly(butylene naphthalate)

    International Nuclear Information System (INIS)

    Yasuniwa, Munehisa; Tsubakihara, Shinsuke; Fujioka, Takashi

    2003-01-01

    Melt-recrystallization in the heating process of poly(butylene naphthalate) (PBN) was studied with X-ray analysis and differential scanning calorimetry (DSC). DSC melting curve of an isothermally crystallized sample showed double endothermic peaks. With increasing the temperature, wide-angle X-ray diffraction (WAXD) patterns of the sample were obtained successively. Crystal structure did not change during the double melting process. The X-ray diffraction intensity decreased gradually in the temperature region up to about 200 deg. C, and then increased distinctly before steep decrease due to the final melting. This increase is interpreted as a proof of recrystallization. The temperature derivative curve of the diffraction intensity was similar to the DSC melting curve

  16. Scarification with sulphuric acid of Schizolobium amazonicum Huber ex Ducke seeds - FABACEAE Escarificação com ácido sulfúrico de sementes de Schizolobium amazonicum Huber ex Ducke - FABACEAE

    Directory of Open Access Journals (Sweden)

    Eniel David Cruz

    2007-06-01

    Full Text Available Seed coat impermeability to water occurs in many species, including Schizolobium amazonicum Huber ex Ducke. To promote germination in seeds with coat impermeability the use of sulphuric acid (H2SO4 is recommended. The objective of this study was to identify a better time for the scarification with sulphuric acid for S. amazonicum seeds. The effect of scarification with sulphuric acid for 20, 40 and 60 min on germination and speed germination was studied for seeds that were either sowed immediately after scarification or after a 24-hour period of immersion in water. Seeds were sown on a mix of sand and sawdust (1:1. The experimental design was completely randomized with four replications of 50 seeds. The statistical analysis of germination was carried out at six, nine, 12, 15, 18, 21 and 24 days after sowing, in a factorial scheme. For speed germination the means were compared by the Tukey test. There was an interaction between treatments to overcome dormancy and immersion time after scarification in most evaluations. Immersion in water accelerated the beginning of germination. All treatments to overcome dormancy promoted seed germination. However, scarification for 60 min, showed better germination, 92% when immediately sown and 86.5% when sown after 24 hours. Speed germination index was highest for scarified seeds for 60 min followed by immersion in water. Scarification for 60 min was the most efficient treatment to promote germination in S. amazonicum seeds.Impermeabilidade do tegumento da semente à água ocorre em muitas espécies, inclusive em Schizolobium amazonicum Huber ex Ducke. Para promover a germinação de sementes com tegumento impermeável um dos métodos recomendados é o uso de ácido sulfúrico (H2SO4. O objetivo desse estudo foi identificar o melhor tempo de escarificação com ácido sulfúrico na superação da dormência em sementes de S. amazonicum, escarificadas durante 20, 40 e 60 minutos. Parte das sementes foi semeada

  17. Immobilization of Acidithiobacillus ferrooxidans on sulfonated microporous poly(styrene-divinylbenzene) copolymer with granulated activated carbon and its use in bio-oxidation of ferrous iron.

    Science.gov (United States)

    Koseoglu-Imer, Derya Yuksel; Keskinler, Bulent

    2013-01-01

    The immobilization efficiencies of Acidithiobacillus ferrooxidans cells on different immobilization matrices were investigated for biooxidation of ferrous iron (Fe(2+)) to ferric iron (Fe(3+)). Six different matrices were used such as the polyurethane foam (PUF), granular activated carbon (GAC), raw poly(styrene-divinylbenzene) copolymer (rawSDVB), raw poly(styrene-divinylbenzene) copolymer with granular activated carbon (rawSDVB-GAC), sulfonated poly(styrene-divinylbenzene) copolymer (sulfSDVB) and sulfonated poly(styrene-divinylbenzene) copolymer with granular activated carbon (sulfSDVB-GAC). The sulfSDVB-GAC polymer showed the best performance for Fe(2+) biooxidation. It was used at packed-bed bioreactor and the kinetic parameters were obtained. The highest Fe(2+) biooxidation rate (R) was found to be 4.02 g/L h at the true dilution rate (Dt) of 2.47 1/h and hydraulic retention time (τ) of 0.4 h. The sulfSDVB-GAC polymer was used for the first time as immobilization material for A. ferrooxidans for Fe(2+) biooxidation. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Design Processes and Criteria for the X-51A Flight Vehicle Airframe

    National Research Council Canada - National Science Library

    Lane, Jeffrey

    2007-01-01

    .... This paper summarizes the X-51A vehicle mission requirements, system design, design processes used for airframe synthesis, design safety factors, success criteria and issues facing the incorporation...

  19. Comparison of light and x-ray sensitometric responses of double-emulsion films for different processing conditions

    International Nuclear Information System (INIS)

    Blendl, Christian; Buhr, Egbert

    2001-01-01

    The effects of different film processing conditions on light and x-ray sensitometric responses were compared for a variety of double-emulsion x-ray films. The processing conditions were altered by changes of the developer temperature. Three different exposure variants were applied: x-ray sensitometry using two stepped neutral density attenuators between film and screens, simultaneous double-sided light sensitometry, and single-sided light sensitometry. 13 different types of double-emulsion x-ray films were investigated, among them three asymmetric films. In the special case of exposing the asymmetric films with the single-sided light sensitometer, a method was investigated where each side of the film is exposed at different locations and the sum effect is analyzed. From each sensitometric curve shape two parameters, the logarithmic speed (log S) and the average gradient (G), were evaluated. The results of this study can be summarized as follows: (1) Single-sided and double-sided light sensitometers revealed almost equal changes of log S when the processing conditions are altered. Thus, single-sided light sensitometers can serve as a substitute for double-sided light sensitometers provided that suited exposure methods are used and appropriate sensitometric parameters are evaluated. (2) Light sensitometry quantitatively indicated changes of the film processing that affect the x-ray speed. Hence, light sensitometry is a useful method to monitor changes in film processing

  20. Visual detection of particulates in x-ray images of processed meat products

    Science.gov (United States)

    Schatzki, Thomas F.; Young, Richard; Haff, Ron P.; Eye, J.; Wright, G.

    1996-08-01

    A study was conducted to test the efficacy of detecting particulate contaminants in processed meat samples by visual observation of line-scanned x-ray images. Six hundred field- collected processed-product samples were scanned at 230 cm2/s using 0.5 X 0.5-mm resolution and 50 kV, 13 mA excitation. The x-ray images were image corrected, digitally stored, and inspected off-line, using interactive image enhancement. Forty percent of the samples were spiked with added contaminants to establish the visual recognition of contaminants as a function of sample thickness (1 to 10 cm), texture of the x-ray image (smooth/textured), spike composition (wood/bone/glass), size (0.1 to 0.4 cm), and shape (splinter/round). The results were analyzed using a maximum likelihood logistic regression method. In packages less than 6 cm thick, 0.2-cm-thick bone chips were easily recognized, 0.1-cm glass splinters were recognized with some difficulty, while 0.4-cm-thick wood was generally missed. Operational feasibility in a time-constrained setting was confirmed. One half percent of the samples arriving from the field contained bone slivers > 1 cm long, 1/2% contained metallic material, while 4% contained particulates exceeding 0.3 cm in size. All of the latter appeared to be bone fragments.

  1. Ultrafast atomic process in X-ray emission by using inner-shell ionization method for sodium and carbon atoms

    Energy Technology Data Exchange (ETDEWEB)

    Moribayashi, Kengo; Sasaki, Akira; Tajima, Toshiki [Japan Atomic Energy Research Inst., Neyagawa, Osaka (Japan). Kansai Research Establishment

    1998-07-01

    An ultrafast inner-shell ionization process with X-ray emission stimulated by high-intensity short-pulse X-ray is studied. Carbon and sodium atoms are treated as target matter. It is shown that atomic processes of the target determine the necessary X-ray intensity for X-ray laser emission as well as the features of X-ray laser such as wavelength and duration time. The intensity also depends on the density of initial atoms. Furthermore, we show that as the intensity of X-ray source becomes high, the multi-inner-shell ionization predominates, leading to the formation of hollow atoms. As the density of hollow atoms is increased by the pumping X-ray power, the emission of X-rays is not only of significance for high brightness X-ray measurement but also is good for X-ray lasing. New classes of experiments of pump X-ray probe and X-ray laser are suggested. (author)

  2. Practice for dosimetry in an X-ray (bremsstrahlung) facility for radiation processing. 2. ed.

    International Nuclear Information System (INIS)

    2002-01-01

    This practice covers dosimetric procedures to be followed in facility characterization, process qualification, and routine processing using X rays (bremsstrahlung) to ensure that the entire product has been treated within an acceptable range of absorbed doses. Other procedures related to facility characterization, process qualification, and routine processing that may influence absorbed dose in the product are also discussed. The establishment of effective or regulatory dose and X-ray energy limits are not within the scope of this practice. In contrast to monoenergetic gamma rays, the bremsstrahlung energy spectrum extends from low values up to the maximum energy of the electrons incident on the X-ray target (see Section 5 and Annex A1). Dosimetry is only one component of a total quality assurance program for an irradiation facility. Other controls besides dosimetry may be required for specific applications such as medical device sterilization and food preservation. For the irradiation of food and the radiation sterilization of health care products, other specific ISO standards exist. For food irradiation, see ISO/ASTM Practice 51431. For the radiation sterilization of health care products, see ISO 11137:1995. In those areas covered by ISO 11137, that standard takes precedence

  3. Processing of spectral X-ray data with principal components analysis

    CERN Document Server

    Butler, A P H; Cook, N J; Butzer, J; Schleich, N; Tlustos, L; Scott, N; Grasset, R; de Ruiter, N; Anderson, N G

    2011-01-01

    The goal of the work was to develop a general method for processing spectral x-ray image data. Principle component analysis (PCA) is a well understood technique for multivariate data analysis and so was investigated. To assess this method, spectral (multi-energy) computed tomography (CT) data was obtained using a Medipix2 detector in a MARS-CT (Medipix All Resolution System). PCA was able to separate bone (calcium) from two elements with k-edges in the X-ray spectrum used (iodine and barium) within a mouse. This has potential clinical application in dual-energy CT systems and future Medipix3 based spectral imaging where up to eight energies can be recorded simultaneously with excellent energy resolution. (c) 2010 Elsevier B.V. All rights reserved.

  4. The Chandra X-ray Observatory data processing system

    Science.gov (United States)

    Evans, Ian; Cresitello-Dittmar, Mark; Doe, Stephen; Evans, Janet; Fabbiano, Giuseppina; Germain, Gregg; Glotfelty, Kenny; Plummer, David; Zografou, Panagoula

    2006-06-01

    Raw data from the Chandra X-ray Observatory are processed by a set of standard data processing pipelines to create scientifically useful data products appropriate for further analysis by end users. Fully automated pipelines read the dumped raw telemetry byte stream from the spacecraft and perform the common reductions and calibrations necessary to remove spacecraft and instrumental signatures and convert the data into physically meaningful quantities that can be further analyzed by observers. The resulting data products are subject to automated validation to ensure correct pipeline processing and verify that the spacecraft configuration and scheduling matched the observers request and any constraints. In addition, pipeline processing monitors science and engineering data for anomalous indications and trending, and triggers alerts if appropriate. Data products are ingested and stored in the Chandra Data Archive, where they are made available for downloading by users. In this paper, we describe the architecture of the data processing system, including the scientific algorithms that are applied to the data, and interfaces to other subsystems. We place particular emphasis on the impacts of design choices on system integrity and maintainability. We review areas where algorithmic improvements or changes in instrument characteristics have required significant enhancements, and the mechanisms used to effect these changes while assuring continued scientific integrity and robustness. We discuss major enhancements to the data processing system that are currently being developed to automate production of the Chandra Source Catalog.

  5. Effect of process conditions and chemical composition on the microstructure and properties of chemically vapor deposited SiC, Si, ZnSe, ZnS and ZnS(x)Se(1-x)

    Science.gov (United States)

    Pickering, Michael A.; Taylor, Raymond L.; Goela, Jitendra S.; Desai, Hemant D.

    1992-01-01

    Subatmospheric pressure CVD processes have been developed to produce theoretically dense, highly pure, void-free and large area bulk materials, SiC, Si, ZnSe, ZnS and ZnS(x)Se(1-x). These materials are used for optical elements, such as mirrors, lenses and windows, over a wide spectral range from the VUV to the IR. We discuss the effect of CVD process conditions on the microstructure and properties of these materials, with emphasis on optical performance. In addition, we discuss the effect of chemical composition on the properties of the composite material ZnS(x)Se(1-x). We first present a general overview of the bulk CVD process and the relationship between process conditions, such as temperature, pressure, reactant gas concentration and growth rate, and the microstructure, morphology and properties of CVD-grown materials. Then we discuss specific results for CVD-grown SiC, Si, ZnSe, ZnS and ZnS(x)Se(1-x).

  6. Melt spin processing and recrystallization of REBa2Cu3O7-x

    International Nuclear Information System (INIS)

    Folkerts, T.J.; Kramer, M.J.; Dennis, K.W.; McCallum, R.W.

    1992-01-01

    This paper introduces a containerless melt-spin processing technique for REBa 2 Cu 3 O 7-x using pre-reacted oxide powders which are rapidly melted and subsequentially quenched in a controlled atmosphere. This results in flakes with typical dimensional of 3000 x 150 x 15μm 3 . Gd123 and Nd123 form nearly amorphous ribbons with only minor BaCu 2 O 2 when dropped in N 2 . Y123 contains Y 2 O 3 , but that the Ba-Cu-P phases present depend on the processing parameters. SEM and TEM studies show these phases are finely diapered; the typical grain size for Y 2 O 3 is 1-2μm, and for the Ba-Cu-O phases it is <0.5μm. Upon recrystallization from the amorphous ribbon, the Gd123 and Nd123 form field directly into the 123 phase while the recrystallization of the Y123 ribbons is less direct

  7. Data processing of X-ray fluorescence analysis using an electronic computer

    International Nuclear Information System (INIS)

    Yakubovich, A.L.; Przhiyalovskij, S.M.; Tsameryan, G.N.; Golubnichij, G.V.; Nikitin, S.A.

    1979-01-01

    Considered are problems of data processing of multi-element (for 17 elements) X-ray fluorescence analysis of tungsten and molybdenum ores. The analysis was carried out using silicon-lithium spectrometer with the energy resolution of about 300 eV and a 1024-channel analyzer. A characteristic radiation of elements was excited with two 109 Cd radioisotope sources, their general activity being 10 mCi. The period of measurements was 400 s. The data obtained were processed with a computer using the ''Proba-1'' and ''Proba-2'' programs. Data processing algorithms and computer calculation results are presented

  8. Convenient hydrothermal decomposition process for preparation of nanocrystalline mineral Cu3BiS3 and Pb1-xBi2x/3S

    International Nuclear Information System (INIS)

    Hu Junqing; Deng Bin; Wang Chunrui; Tang Kaibin; Qian Yitai

    2003-01-01

    Mineral nanocrystalline Cu 3 BiS 3 and Pb 1-x Bi 2x/3 S (or Bi 0.22 Pb 0.89 S 1.22 ) have been prepared at low synthetic temperature of 100-150 deg. C by convenient hydrothermal decomposition process. X-ray powder diffraction, transmission electron microscopy, X-ray photoelectron spectra, and element analysis were used to characterize and measure the samples. The as-prepared Cu 3 BiS 3 sample consisted of whisker-like particles with an average size of 50x10 nm 2 and the Pb 1-x Bi 2x/3 S sample displayed aggregative particles with size in the range of 30-50 nm. Preliminary results showed that the prepared precursors, reaction temperature and time played a role in the formation of the final products. A possible reaction mechanism was also discussed briefly

  9. Visual detection of particulates in processed meat products by x ray

    Science.gov (United States)

    Schatzki, Thomas F.; Young, Richard; Haff, Ron P.; Eye, J.; Wright, G.

    1995-01-01

    A test has been run to study the efficacy of detecting particulate contaminants in processed meat samples by manual observation of line-scanned x-ray images. Six hundred processed product samples arriving over a 3 month period at a national USDA-FSIS laboratory were scanned at 230 cm2sec with 0.5 X 0.5 mm resolution, using 50 KV, 13 ma excitation, with digital interfacing and image correction. Images were inspected off-line, using interactive image enhancement. Forty percent of the samples were spiked, blind to the analyst, in order to establish the manual recognition rate as a function of sample thickness [1 - 10 cm] and texture of the x-ray image [smooth/textured], as well as spike composition [wood/bone/glass], size [1 - 4 mm] and shape [splinter/round]. The results have been analyzed using maximum likelihood logistic regression. In meat packages less than 6 cm thick, 2 mm bone chips are easily recognized, 1 mm glass splinters with some difficulty, while wood is generally missed even at 4 mm. Operational feasibility in a time-constrained setting has bee confirmed. One half percent of the samples arriving from the field contained bone slivers > 1 cm long, one half percent contained metallic material, while 4% contained particulates exceeding 3.2 mm in size. All of the latter appeared to be bone fragments.

  10. Development of an alternating magnetic-field-assisted finishing process for microelectromechanical systems micropore x-ray optics.

    Science.gov (United States)

    Riveros, Raul E; Yamaguchi, Hitomi; Mitsuishi, Ikuyuki; Takagi, Utako; Ezoe, Yuichiro; Kato, Fumiki; Sugiyama, Susumu; Yamasaki, Noriko; Mitsuda, Kazuhisa

    2010-06-20

    X-ray astronomy research is often limited by the size, weight, complexity, and cost of functioning x-ray optics. Micropore optics promises an economical alternative to traditional (e.g., glass or foil) x-ray optics; however, many manufacturing difficulties prevent micropore optics from being a viable solution. Ezoe et al. introduced microelectromechanical systems (MEMS) micropore optics having curvilinear micropores in 2008. Made by either deep reactive ion etching or x-ray lithography, electroforming, and molding (LIGA), MEMS micropore optics suffer from high micropore sidewall roughness (10-30nmrms) which, by current standards, cannot be improved. In this research, a new alternating magnetic-field-assisted finishing process was developed using a mixture of ferrofluid and microscale abrasive slurry. A machine was built, and a set of working process parameters including alternating frequency, abrasive size, and polishing time was selected. A polishing experiment on a LIGA-fabricated MEMS micropore optic was performed, and a change in micropore sidewall roughness of 9.3+/-2.5nmrms to 5.7+/-0.7nmrms was measured. An improvement in x-ray reflectance was also seen. This research shows the feasibility and confirms the effects of this new polishing process on MEMS micropore optics.

  11. Development of an alternating magnetic-field-assisted finishing process for microelectromechanical systems micropore x-ray optics

    Energy Technology Data Exchange (ETDEWEB)

    Riveros, Raul E.; Yamaguchi, Hitomi; Mitsuishi, Ikuyuki; Takagi, Utako; Ezoe, Yuichiro; Kato, Fumiki; Sugiyama, Susumu; Yamasaki, Noriko; Mitsuda, Kazuhisa

    2010-06-20

    X-ray astronomy research is often limited by the size, weight, complexity, and cost of functioning x-ray optics. Micropore optics promises an economical alternative to traditional (e.g., glass or foil) x-ray optics; however, many manufacturing difficulties prevent micropore optics from being a viable solution. Ezoe et al. introduced microelectromechanical systems (MEMS) micropore optics having curvilinear micropores in 2008. Made by either deep reactive ion etching or x-ray lithography, electroforming, and molding (LIGA), MEMS micropore optics suffer from high micropore sidewall roughness (10-30nmrms) which, by current standards, cannot be improved. In this research, a new alternating magnetic-field-assisted finishing process was developed using a mixture of ferrofluid and microscale abrasive slurry. A machine was built, and a set of working process parameters including alternating frequency, abrasive size, and polishing time was selected. A polishing experiment on a LIGA-fabricated MEMS micropore optic was performed, and a change in micropore sidewall roughness of 9.3{+-}2.5nmrms to 5.7{+-}0.7nmrms was measured. An improvement in x-ray reflectance was also seen. This research shows the feasibility and confirms the effects of this new polishing process on MEMS micropore optics.

  12. Enhancement of dental x-ray images by two channel image processing

    International Nuclear Information System (INIS)

    Mitra, S.; Yu, T.H.

    1991-01-01

    In this paper, the authors develop a new algorithm for the enhancement of low-contrast details of dental X-ray images using a two channel structure. The algorithm first decomposes an input image in the frequency domain into two parts by filtering: one containing the low frequency components and the other containing the high frequency components. Then these parts are enhanced separately using a transform magnitude modifier. Finally a contrast enhanced image is formed by combining these two processed pats. The performance of the proposed algorithm is illustrated through enhancement of dental X-ray images. The algorithm can be easily implemented on a personal computer

  13. Passivation process of X80 pipeline steel in bicarbonate solutions

    Science.gov (United States)

    Zhou, Jian-Long; Li, Xiao-Gang; Du, Cui-Wei; Pan, Ying; Li, Tao; Liu, Qian

    2011-04-01

    The passivation process of X80 pipeline steel in bicarbonate solutions was investigated using potentiodynamic, dynamic electrochemical impedance spectroscopy (DEIS), and Mott-Schottky measurements. The results show that the shape of polarization curves changes with HCO{3/-} concentration. The critical `passive' concentration is 0.009 mol/L HCO{3/-} for X80 pipeline steel in bicarbonate solutions. No anodic current peak exists in HCO3/- solutions when the concentration is lower than 0.009 mol/L, whereas there are one and two anodic current peaks when the HCO3/- concentration ranges from 0.009 to 0.05 mol/L and is higher than 0.1 mol/L, respectively. DEIS measurements show that there exist active dissolution range, transition range, pre-passive range, passive layer formation range, passive range, and trans-passive range for X80 pipeline steel in the 0.1 mol/L HCO{3/-} solutions. The results of DEIS measurements are in complete agreement with the potentiodynamic diagram. An equivalent circuit containing three sub-layers is used to explain the Nyquist plots in the passive range. Analyses are well made for explaining the corresponding fitted capacitance and impedance. The Mott-Schottky plots show that the passive film of X80 pipeline steel is an n-type semiconductor, and capacitance measurements are in good accordance with the results of DEIS experiment.

  14. Aqueous-Processed Inorganic Thin-Film Solar Cells Based on CdSe(x)Te(1-x) Nanocrystals: The Impact of Composition on Photovoltaic Performance.

    Science.gov (United States)

    Zeng, Qingsen; Chen, Zhaolai; Zhao, Yue; Du, Xiaohang; Liu, Fangyuan; Jin, Gan; Dong, Fengxia; Zhang, Hao; Yang, Bai

    2015-10-21

    Aqueous processed nanocrystal (NC) solar cells are attractive due to their environmental friendliness and cost effectiveness. Controlling the bandgap of absorbing layers is critical for achieving high efficiency for single and multijunction solar cells. Herein, we tune the bandgap of CdTe through the incorporation of Se via aqueous process. The photovoltaic performance of aqueous CdSexTe1-x NCs is systematically investigated, and the impacts of charge generation, transport, and injection on device performance for different compositions are deeply discussed. We discover that the performance degrades with the increasing Se content from CdTe to CdSe. This is mainly ascribed to the lower conduction band (CB) of CdSexTe1-x with higher Se content, which reduces the driving force for electron injection into TiO2. Finally, the performance is improved by mixing CdSexTe1-x NCs with conjugated polymer poly(p-phenylenevinylene) (PPV), and power conversion efficiency (PCE) of 3.35% is achieved based on ternary NCs. This work may provide some information to further optimize the aqueous-processed NC and hybrid solar cells.

  15. Influence of near-edge processes in the elemental analysis using X

    Indian Academy of Sciences (India)

    The near-edge processes, such as X-ray absorption fine structure (XAFS) andresonant ... away from the shell/subshell ionization thresholds of the attenuator element. ... The influence of XAFS to the attenuation coefficient depends upon the ...

  16. Processing-property relations in YBa2Cu3O(6+x) superconductors

    Science.gov (United States)

    Safari, A.; Wachtman, J. B., Jr.; Parkhe, V.; Caracciolo, R.; Jeter, D.

    Processing of YBa2Cu3O(6+x) superconducting samples by employing different precursor powder preparation techniques such as ball milling, attrition milling, and narrow particle size distribution powder preparation through coprecipitation by spraying will be discussed. CuO coated with oxalates shows the lowest resistance above Tc up to room temperature. The extent of corrosion by water has been studied by employing magnetic susceptibility, XPS, and X-ray diffraction. Superconducting samples are affected to a considerable extent when treated in water at 60 C and the severity of the attack increases with time.

  17. Preparation of Sm2Fe17-xGaxNy/Cy magnets by a hydrogenation-disproportionation-desorption-recombination process

    International Nuclear Information System (INIS)

    Kubis, M.; Cao, L.; Handstein, A.; Gebel, B.; Mueller, K.; Schultz, L.

    1997-01-01

    A hydrogenation-disproportionation-desorption-recombination process (HDDR) was applied to Sm 2 Fe 17-x Ga x (x=0.5, 1, and 2). The process was studied by means of temperature-pressure analysis, x-ray diffraction and scanning electron microscopy. It was shown that Ga not only stabilizes the interstitially modified compounds Sm 2 Fe 17-x Ga x C y (0 2 Fe 17-x Ga x against the disproportionation by hydrogen. Therefore, only for x=0.5 can a nearly complete HDDR be performed. The HDDR-treated and subsequently nitrogenated or carburized samples show coercivities μ 0J H C up to 3.1 T and 2.5 T, respectively. Hot compaction increases the density of the Sm 2 Fe 16.5 Ga 0.5 C y powder; however, it leads to a loss of coercivity due to decomposition into α-iron and samarium carbides. copyright 1997 American Institute of Physics

  18. Physics of accretion and ejection processes: a multi-wavelengths study of galactic X-ray binaries

    International Nuclear Information System (INIS)

    Prat, Lionel

    2010-01-01

    This manuscript is dedicated to the study of the accretion and ejection processes in X-ray Binaries, using radio and X-ray observations as well as numerical simulations. The links and interplay between the accretion disc, the corona and the compact jet. In an introductory part, I first describe the main observational and theoretical properties of the X-ray binaries. I especially emphasize the aspects required to understand the work reported in this manuscript. I also describe the main X-ray and radio observatories used during this work. Then, the first part of this manuscript is dedicated to the accretion processes in X-ray Binaries. I use high energy observations to study one High Mass X-ray Binary (IGR J19140+0951) and two Low-Mass X-ray Binaries (XTE J1818-245 and H1743-322). In the case of IGR Jl9140+0951, observations show that the luminosity generated by the accretion processes can deeply alter the stellar wind. In the case of the two Low Mass X-ray Binaries, I estimate several important parameters of the Systems using the behavior of their accretion discs. The second part is dedicated to the interplay between the accretion disc and the other components of the Systems, namely the corona and the compact jet. Using simultaneous X-ray and radio observations, I show that the corona undergo a strong evolution prior to a discrete ejection of matter, in the case of several binary Systems. In the case of GRS 1915+105, evolution of the corona and detection of a discrete ejection appear within a few seconds, while for other sources it takes a few hours. I study also the link between the accretion disc and the compact jet using a correlation between radio and X-ray flux: depending on the System, the link between the accretion energy brought by the accretion disc and the luminosity of the jet is different, indicating that different physical processes are at work. Finally, the third part is dedicated to numerical simulations of the accretion disc, in the case where an

  19. Integrated assessment of thermal hydraulic processes in W7-X fusion experimental facility

    Energy Technology Data Exchange (ETDEWEB)

    Kaliatka, T., E-mail: tadas.kaliatka@lei.lt; Uspuras, E.; Kaliatka, A.

    2017-02-15

    Highlights: • The model of Ingress of Coolant Event experiment facility was developed using the RELAP5 code. • Calculation results were compared with Ingress of Coolant Event experiment data. • Using gained experience, the numerical model of Wendelstein 7-X facility was developed. • Performed analysis approved pressure increase protection system for LOCA event. - Abstract: Energy received from the nuclear fusion reaction is one of the most promising options for generating large amounts of carbon-free energy in the future. However, physical and technical problems existing in this technology are complicated. Several experimental nuclear fusion devices around the world have already been constructed, and several are under construction. However, the processes in the cooling system of the in-vessel components, vacuum vessel and pressure increase protection system of nuclear fusion devices are not widely studied. The largest amount of radioactive materials is concentrated in the vacuum vessel of the fusion device. Vacuum vessel is designed for the vacuum conditions inside the vessel. Rupture of the in-vessel components of the cooling system pipe may lead to a sharp pressure increase and possible damage of the vacuum vessel. To prevent the overpressure, the pressure increase protection system should be designed and implemented. Therefore, systematic and detailed experimental and numerical studies, regarding the thermal-hydraulic processes in cooling system, vacuum vessel and pressure increase protection system, are important and relevant. In this article, the numerical investigation of thermal-hydraulic processes in cooling systems of in-vessel components, vacuum vessels and pressure increase protection system of fusion devices is presented. Using the experience gained from the modelling of “Ingress of Coolant Event” experimental facilities, the numerical model of Wendelstein 7-X (W7-X) experimental fusion device was developed. The integrated analysis of the

  20. An Application of X-ray Fluorescence as Process Analytical Technology (PAT) to Monitor Particle Coating Processes.

    Science.gov (United States)

    Nakano, Yoshio; Katakuse, Yoshimitsu; Azechi, Yasutaka

    2018-03-30

    An attempt to apply X-ray Fluorescence (XRF) analysis to evaluate small particle coating process as a Process Analytical Technologies (PAT) was made. The XRF analysis was used to monitor coating level in small particle coating process with at-line manner. The small particle coating process usually consists of multiple coating processes. This study was conducted by a simple coating particles prepared by first coating of a model compound (DL-methionine) and second coating by talc on spherical microcrystalline cellulose cores. The particles with two layered coating are enough to demonstrate the small particle coating process. From the result by the small particle coating process, it was found that the XRF signal played different roles, resulting that XRF signals by first coating (layering) and second coating (mask coating) could demonstrate the extent with different mechanisms for the coating process. Furthermore, the particle coating of the different particle size has also been investigated to evaluate size effect of these coating processes. From these results, it was concluded that the XRF could be used as a PAT in monitoring particle coating processes and become powerful tool in pharmaceutical manufacturing.

  1. Development of an alternating magnetic-field-assisted finishing process for microelectromechanical systems micropore x-ray optics

    International Nuclear Information System (INIS)

    Riveros, Raul E.; Yamaguchi, Hitomi; Mitsuishi, Ikuyuki; Takagi, Utako; Ezoe, Yuichiro; Kato, Fumiki; Sugiyama, Susumu; Yamasaki, Noriko; Mitsuda, Kazuhisa

    2010-01-01

    X-ray astronomy research is often limited by the size, weight, complexity, and cost of functioning x-ray optics. Micropore optics promises an economical alternative to traditional (e.g., glass or foil) x-ray optics; however, many manufacturing difficulties prevent micropore optics from being a viable solution. Ezoe et al. introduced microelectromechanical systems (MEMS) micropore optics having curvilinear micropores in 2008. Made by either deep reactive ion etching or x-ray lithography, electroforming, and molding (LIGA), MEMS micropore optics suffer from high micropore sidewall roughness (10-30nmrms) which, by current standards, cannot be improved. In this research, a new alternating magnetic-field-assisted finishing process was developed using a mixture of ferrofluid and microscale abrasive slurry. A machine was built, and a set of working process parameters including alternating frequency, abrasive size, and polishing time was selected. A polishing experiment on a LIGA-fabricated MEMS micropore optic was performed, and a change in micropore sidewall roughness of 9.3±2.5nmrms to 5.7±0.7nmrms was measured. An improvement in x-ray reflectance was also seen. This research shows the feasibility and confirms the effects of this new polishing process on MEMS micropore optics.

  2. X-ray scattering studies of non-equilibrium ordering processes

    International Nuclear Information System (INIS)

    Nagler, S.E.

    1991-01-01

    We report on the progress of the project entitled ''X-ray Scattering Studies of Non-Equilibrium Ordering Processes.'' The past year has seen continued progress in the study of kinetic effects in metallic binary alloys and polymers. In addition, work has begun on a low dimensional CDW system: blue bronze. A sample chamber has been constructed to perform small angle neutron scattering measurements on a model quantum system with phase separation: solid He3/He4. Work is continuing on magnetic systems. Planned future experiments include an investigation of crystallization in Rubidium

  3. Exact run length distribution of the double sampling x-bar chart with estimated process parameters

    Directory of Open Access Journals (Sweden)

    Teoh, W. L.

    2016-05-01

    Full Text Available Since the run length distribution is generally highly skewed, a significant concern about focusing too much on the average run length (ARL criterion is that we may miss some crucial information about a control chart’s performance. Thus it is important to investigate the entire run length distribution of a control chart for an in-depth understanding before implementing the chart in process monitoring. In this paper, the percentiles of the run length distribution for the double sampling (DS X chart with estimated process parameters are computed. Knowledge of the percentiles of the run length distribution provides a more comprehensive understanding of the expected behaviour of the run length. This additional information includes the early false alarm, the skewness of the run length distribution, and the median run length (MRL. A comparison of the run length distribution between the optimal ARL-based and MRL-based DS X chart with estimated process parameters is presented in this paper. Examples of applications are given to aid practitioners to select the best design scheme of the DS X chart with estimated process parameters, based on their specific purpose.

  4. Atividade antioxidante e antimicrobiana de extratos de atemoia (Annona cherimola Mill. x A. squamosa L.

    Directory of Open Access Journals (Sweden)

    Suzana Vieira Rabêlo

    2014-01-01

    Full Text Available O objetivo deste trabalho foi quantificar os teores de fenóis e flavonoides totais, bem como avaliar as atividades antioxidante e antimicrobiana de extratos obtidos dos talos e folhas de atemoia (A. cherimola Mill. x A. squamosa L., que pertence à família Annonaceae. A atividade antioxidante foi avaliada pelos métodos de sequestro dos radicais 2,2-difenil-1-picrilhidrazil (DPPH e 2,2'-azinobis-3-etilbenzotiazolina-6-ácido sulfônico (ABTS, bem como pelo método da cooxidação do β-caroteno/ácido linoleico. A avaliação da atividade antimicrobiana dos extratos foi analisada contra 10 cepas de bactérias. Os resultados da atividade antioxidante dos extratos mostraram que o extrato etanólico dos talos (EEt foi o antioxidante mais efetivo (IC50 = 10,44 ± 1,25 µg/mL no método do sequestro do DPPH, bem como no sequestro do radical ABTS (24,81 ± 0,49%. O extrato hexânico das folhas apresentou o melhor percentual de atividade antioxidante no ensaio do β-caroteno/ácido linoleico (41,12 ± 4,35%. Os extratos etanólico dos talos e metanólico das folhas mostraram-se ativos contra cepas de Bacillus cereus, Klebsiella pneumoniae, Staphylococcus aureus resistente à meticilina (MRSA, Staphylococcus aureus e Staphylococcus epidermidis.

  5. Radiation processing of food products with 5 MV Bremsstrahlung x-rays

    International Nuclear Information System (INIS)

    Petwal, V.C.; Soni, H.C.

    2004-01-01

    Foods and agricultural products are treated with ionizing radiation to accomplish many different goals. The desired goals may be the reduction of pathogenic bacteria, other microorganisms and parasites that cause food borne diseases; or inactivation of food spoilage organisms, including bacteria, molds, and yeasts; or lengthening the shelf-life of fresh fruits and vegetables by decreasing the normal biological changes associated with growth and maturation processes, such as ripening or sprouting. It has become more important due to mounting concern over food born diseases, and growing international trade in food products that must meet stiff import standards of quality and quarantine. A 10 MeV 10 kW LINAC based multi-product EB radiation processing facility is being established at CAT to meet the processing requirement of various food, agricultural and medical products. The facility will be operated in two modes: (a) Electron: 10 MeV, 10 kW (b) Photon: 5 MeV, 10 kW Treatment with electron beam provides the highest processing rate and lowest unit cost. But the electrons have relatively short range in the solid product, hence the maximum product areal density (density times depth) that can be processed using direct 10 MeV electron beam is limited to about 8.5 gm/cm 2 (double sided irradiation). On the other hand x-rays are more penetrating, hence can be used to process the products having larger areal densities e.g. onions and potatoes packed in gunny bags. In order to address various issues related to food irradiation using 5 MV X-ray beam, a mathematical model is developed on the basis of the analytical calculations and experimental data presented by R.B.Miller, 2003, and J. Meissner et.al, 2000. (author)

  6. MMX-I: A data-processing software for multi-modal X-ray imaging and tomography

    International Nuclear Information System (INIS)

    Bergamaschi, A; Medjoubi, K; Somogyi, A; Messaoudi, C; Marco, S

    2017-01-01

    Scanning hard X-ray imaging allows simultaneous acquisition of multimodal information, including X-ray fluorescence, absorption, phase and dark-field contrasts, providing structural and chemical details of the samples. Combining these scanning techniques with the infrastructure developed for fast data acquisition at Synchrotron Soleil permits to perform multimodal imaging and tomography during routine user experiments at the Nanoscopium beamline. A main challenge of such imaging techniques is the online processing and analysis of the generated very large volume (several hundreds of Giga Bytes) multimodal data-sets. This is especially important for the wide user community foreseen at the user oriented Nanoscopium beamline (e.g. from the fields of Biology, Life Sciences, Geology, Geobiology), having no experience in such data-handling. MMX-I is a new multi-platform open-source freeware for the processing and reconstruction of scanning multi-technique X-ray imaging and tomographic datasets. The MMX-I project aims to offer, both expert users and beginners, the possibility of processing and analysing raw data, either on-site or off-site. Therefore we have developed a multi-platform (Mac, Windows and Linux 64bit) data processing tool, which is easy to install, comprehensive, intuitive, extendable and user-friendly. MMX-I is now routinely used by the Nanoscopium user community and has demonstrated its performance in treating big data. (paper)

  7. MMX-I: A data-processing software for multi-modal X-ray imaging and tomography

    Science.gov (United States)

    Bergamaschi, A.; Medjoubi, K.; Messaoudi, C.; Marco, S.; Somogyi, A.

    2017-06-01

    Scanning hard X-ray imaging allows simultaneous acquisition of multimodal information, including X-ray fluorescence, absorption, phase and dark-field contrasts, providing structural and chemical details of the samples. Combining these scanning techniques with the infrastructure developed for fast data acquisition at Synchrotron Soleil permits to perform multimodal imaging and tomography during routine user experiments at the Nanoscopium beamline. A main challenge of such imaging techniques is the online processing and analysis of the generated very large volume (several hundreds of Giga Bytes) multimodal data-sets. This is especially important for the wide user community foreseen at the user oriented Nanoscopium beamline (e.g. from the fields of Biology, Life Sciences, Geology, Geobiology), having no experience in such data-handling. MMX-I is a new multi-platform open-source freeware for the processing and reconstruction of scanning multi-technique X-ray imaging and tomographic datasets. The MMX-I project aims to offer, both expert users and beginners, the possibility of processing and analysing raw data, either on-site or off-site. Therefore we have developed a multi-platform (Mac, Windows and Linux 64bit) data processing tool, which is easy to install, comprehensive, intuitive, extendable and user-friendly. MMX-I is now routinely used by the Nanoscopium user community and has demonstrated its performance in treating big data.

  8. Evaluation of a computer aided X-ray fluorographic system: Part II - image processing

    International Nuclear Information System (INIS)

    Burch, S.F.; Cocking, S.J.

    1981-12-01

    The TV imagery from a computer aided X-ray fluorographic system has been digitally processed with an I 2 S model 70E image processor, controlled by a PDP 11/60 minicomputer. The image processor allowed valuable processing for detection of defects in cast components to be carried out at television frame rates. Summation of TV frames was used to reduce noise, and hence improve the thickness sensitivity of the system. A displaced differencing technique and interactive contrast enhancement were then used to improve the reliability of inspection by removing spurious blemishes and interference lines, while simultaneously enhancing the visibility of real defects. The times required for these operations are given, and the benefits provided for X-ray fluorography are illustrated by the results from inspection of aero engine castings. (author)

  9. In-situ real-time x-ray scattering for probing the processing-structure-performance relation

    KAUST Repository

    Smilgies, Detlef-M.

    2014-01-01

    © 2014 Materials Research Society. In-situ X-ray scattering methodology is discussed, in order to analyze the microstructure development of soft functional materials during coating, annealing, and drying processes in real-time. The relevance of a fundamental understanding of coating processes for future industrial production is pointed out.

  10. Removal of NOsub(x) and SO2 by the electron beam process

    International Nuclear Information System (INIS)

    Fuchs, P.; Roth, B.; Schwing, U.; Angele, H.; Gottstein, J.

    1988-01-01

    The electron beam process (EBP) is a dry method of flue gas purification for the simultaneous removal of NOsub(x) and SO 2 . The process has the potential to be used as a retrofit for existing coal fired power plants. Since the beginning of last year Badenwerk AG, in an association with other partners, has run a pilot plant incorporating this process in the new Unit No. 7 of the Rheinhafen-Dampfkraftwerk in Karlsruhe. The design and the operation as well as an account of test results and the experience accumulated during the operation of the facility are presented. (author)

  11. Portable pulse X-ray micro and nanosecond range apparatus for studying fast-going processes in opaque media

    International Nuclear Information System (INIS)

    Goganov, D.A.; Komyak, N.I.; Pelix, E.A.

    Pulse X-radiography (X-ray flash duration in the order of 10 -6 -10 -9 sec) is the principal method for studying fast-going processes in opaque media by serial and parallel radiographic imaging. Description is given and main features are outlined of pulse X-ray apparatus IRA-4b, 5b, 6b producing X-radiation flashes from 0.3 μsec to 10-20 nsec in duration

  12. INFLUÊNCIA DAS CONCENTRAÇÕES DE ÁCIDO SULFÚRICO NA GERMINAÇÃO IN VITRO DE Pterogyne nitens TUL. (FABACEAE

    Directory of Open Access Journals (Sweden)

    Rosália Nazareth Rosa Trindade

    2017-01-01

    Full Text Available O objetivo foi avaliar o efeito de diferentes concentrações de ácido sulfúrico na desinfestação, oxidação e germinação in vitro de sementes de Pterogyne nitens. O experimento foi conduzido no laboratório de Cultura de Tecidos Vegetais do IFMG. O delineamento foi inteiramente ao acaso, com quatro repetições de 12 sementes, sendo estudado o efeito de cinco concentrações de ácido sulfúrico. A avaliação do número de sementes germinadas, oxidadas e desinfestadas foi feita três vezes por semana, por 20 dias. Os dados foram submetidos à análise de variância. As maiores porcentagens de desinfestação 27,08 e 16,67% foi observado nas sementes tratadas com 25 e 100% do ácido. Os tratamentos com 75 e 100% de ácido sulfúrico não se diferenciaram e apresentaram maiores porcentagens de germinação (93,75 e 83,33%, respectivamente e oxidação (89,58 e 83,33 %, respectivamente. A concentração de 100% de ácido sulfúrico apresentou os melhores resultados para a desinfestação e germinação.

  13. A novel process control method for a TT-300 E-Beam/X-Ray system

    Science.gov (United States)

    Mittendorfer, Josef; Gallnböck-Wagner, Bernhard

    2018-02-01

    This paper presents some aspects of the process control method for a TT-300 E-Beam/X-Ray system at Mediscan, Austria. The novelty of the approach is the seamless integration of routine monitoring dosimetry with process data. This allows to calculate a parametric dose for each production unit and consequently a fine grain and holistic process performance monitoring. Process performance is documented in process control charts for the analysis of individual runs as well as historic trending of runs of specific process categories over a specified time range.

  14. Thermoelectric properties of p-type (Bi{sub 1{minus}x}Sb{sub x}){sub 2}Te{sub 3} fabricated by mechanical alloying process

    Energy Technology Data Exchange (ETDEWEB)

    Jung, B Y; Choi, J S; Oh, T S; Hyun, D B

    1997-07-01

    Thermoelectric properties of polycrystalline (Bi{sub 1{minus}x}Sb{sub x}){sub 2}Te{sub 3} (0.75 {le} x {le} 0.85), fabricated by mechanical alloying and hot pressing methods, have been investigated. Formation of (Bi{sub 0.25}Sb{sub 0.75}){sub 2}Te{sub 3} alloy powder was completed by mechanical alloying for 5 hours at ball-to-material ratio of 5:1, and processing time for (Bi{sub 1{minus}sub x}Sb{sub x}){sub 2}Te{sub 3} formation increased with Sb{sub 2}Te{sub 3} content x. When (Bi{sub 0.25}Sb{sub 0.75}){sub 2}Te{sub 3} was hot pressed at temperatures ranging from 300 C to 550 C for 30 minutes, figure-of-merit increased with hot pressing temperature and maximum value of 2.8 x 10{sup {minus}3}/K could be obtained by hot pressing at 550 C. When hot pressed at 550 C, (Bi{sub 0.2}Sb{sub 0.8}){sub 2}Te{sub 3} exhibited figure-of-merit of 2.92 x 10{sup {minus}3}/K, which could be improved to 2.97 x 10{sup {minus}3}/K with addition of 1 wt% Sb as acceptor dopant.

  15. Depth Profile of Impurity Phase in Wide-Bandgap Cu(In1-x ,Ga x )Se2 Film Fabricated by Three-Stage Process

    Science.gov (United States)

    Wang, Shenghao; Nazuka, Takehiro; Hagiya, Hideki; Takabayashi, Yutaro; Ishizuka, Shogo; Shibata, Hajime; Niki, Shigeru; Islam, Muhammad M.; Akimoto, Katsuhiro; Sakurai, Takeaki

    2018-02-01

    For copper indium gallium selenide [Cu(In1-x ,Ga x )Se2, CIGS]-based solar cells, defect states or impurity phase always form due to both the multinary compositions of CIGS film and the difficulty of controlling the growth process, especially for high Ga concentration. To further improve device performance, it is important to understand such formation of impurity phase or defect states during fabrication. In the work presented herein, the formation mechanism of impurity phase Cu2-δ Se and its depth profile in CIGS film with high Ga content, in particular CuGaSe2 (i.e., CGS), were investigated by applying different growth conditions (i.e., normal three-stage process and two-cycle three-stage process). The results suggest that impurity phase Cu2-δ Se is distributed nonuniformly in the film because of lack of Ga diffusion. The formed Cu2-δ Se can be removed by etching the as-deposited CGS film with bromine-methanol solution, resulting in improved device performance.

  16. The Integration Process of Very Thin Mirror Shells with a Particular Regard to Simbol-X

    Science.gov (United States)

    Basso, S.; Pareschi, G.; Tagliaferri, G.; Mazzoleni, F.; Valtolina, R.; Citterio, O.; Conconi, P.

    2009-05-01

    The optics of Simbol-X are very thin compared to previous X-ray missions (like XMM). Therefore their shells floppy and are unable to maintain the correct shape. To avoid the deformations of their very thin X-ray optics during the integration process we adopt two stiffening rings with a good roundness. In this article the procedure used for the first three prototypes of the Simbol-X optics is presented with a description of the problems involved and with an analysis of the degradation of the performances during the integration. This analysis has been performed with the UV vertical bench measurements at INAF-OAB.

  17. INITIATION PROCESSES FOR THE 2013 MAY 13 X1.7 LIMB FLARE

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Jinhua [Xinjiang Astronomical Observatory, CAS, 830011, Urumqi (China); Wang, Ya; Zhou, Tuanhui; Ji, Haisheng, E-mail: jihs@pmo.ac.cn [Purple Mountain Observatory, CAS, Nanjing, 210008 (China)

    2017-01-20

    For the X1.7 class flare on 2013 May 13 (SOL2013-05-13T01:53), its initiation process was well observed by the Atmospheric Imaging Assembly (AIA) on board the Solar Dynamic Observatory and the Extreme UltraViolet Imager (EUVI) on board STEREO-B . The initiation process incorporates the following phenomena: an X-ray precursor that started ∼9 minutes before flare onset, two hot magnetic loops (as seen with AIA hot channels) forming a sigmoidal core magnetic structure (as seen with the EUVI), a rapidly formed magnetic flux rope (MFR) that expands outward, and a flare loop that contracts inward. The two hot magnetic loops were activated after the occurrence of the X-ray precursor. After activation, magnetic reconnection occurred between the two hot magnetic loops (inside the sigmoid structure), which produced the expanding MFR and the contracting flare loop (CFL). The MFR and CFL can only be seen with AIA hot and cool channels, respectively. For this flare, the real initiation time can be regarded as being from the starting time of the precursor, and its impulsive phase started when the MFR began its fast expansion. In addition, the CFL and the growing postflare magnetic loops are different loop systems, and the CFL was the product of magnetic reconnection between sheared magnetic fields that also produced the MFR.

  18. INITIATION PROCESSES FOR THE 2013 MAY 13 X1.7 LIMB FLARE

    International Nuclear Information System (INIS)

    Shen, Jinhua; Wang, Ya; Zhou, Tuanhui; Ji, Haisheng

    2017-01-01

    For the X1.7 class flare on 2013 May 13 (SOL2013-05-13T01:53), its initiation process was well observed by the Atmospheric Imaging Assembly (AIA) on board the Solar Dynamic Observatory and the Extreme UltraViolet Imager (EUVI) on board STEREO-B . The initiation process incorporates the following phenomena: an X-ray precursor that started ∼9 minutes before flare onset, two hot magnetic loops (as seen with AIA hot channels) forming a sigmoidal core magnetic structure (as seen with the EUVI), a rapidly formed magnetic flux rope (MFR) that expands outward, and a flare loop that contracts inward. The two hot magnetic loops were activated after the occurrence of the X-ray precursor. After activation, magnetic reconnection occurred between the two hot magnetic loops (inside the sigmoid structure), which produced the expanding MFR and the contracting flare loop (CFL). The MFR and CFL can only be seen with AIA hot and cool channels, respectively. For this flare, the real initiation time can be regarded as being from the starting time of the precursor, and its impulsive phase started when the MFR began its fast expansion. In addition, the CFL and the growing postflare magnetic loops are different loop systems, and the CFL was the product of magnetic reconnection between sheared magnetic fields that also produced the MFR.

  19. Three-dimensional x-ray tomography of crack-resistant composites: New paradigms for process optimization

    Energy Technology Data Exchange (ETDEWEB)

    Kinney, J.H.; Haupt, D.L. [Lawrence Livermore National Laboratory, CA (United States)

    1995-05-01

    The goal of this research is to apply noninvasive, volumetric imaging technology (the x-ray tomographic microscope) to the characterization and process-modeling of ceramic matrix composites. Specifically, we propose to follow the evolution of a composite`s microstructure during chemical vapor infiltration processing, and relate the microstructure to processing parameters and fiber architecture. The results will be used to provide the fundamental and practical understanding necessary for cost-effective intelligent processing of ceramic matrix composites.

  20. The research on x-ray nondestructive testing and image processing technology of explosive components

    International Nuclear Information System (INIS)

    Shi, C.; Zhai, X.; Liu, Z.; Lin, H.

    2004-01-01

    The explosive components will inevitably produce defects such as impurity, crack and degumming during production and storage, therefore the inside substance of the explosive components must be examined and the findings concerned must be identified and estimated in order to ensure the quality and service life of the explosive components. Firstly, some analyses are conducted on the usual X-ray NDT system theory, and the simulation explosive component is made with some pre-built defects such as debonding, cracks, blow holes, impurities, and non-uniform density. The image testing system most fit for the explosive components is established. Secondly, the ways of X-ray digital image processing are discussed; the obtained images are enhanced and restored through the self-accommodating build-up arithmetic and proper restoring methods. By means of the results of the overall comparison and analysis of the digital image processing technology, it is clearly indicated that it is feasible to use X-ray digital-imaging ways to carry out the NDT of explosive components and identify the inside defects. (author)

  1. Alquilación de isobutano con olefinas: estudio de catalizadores sólidos ácidos

    OpenAIRE

    Dalla Costa, Bruno Oscar

    2013-01-01

    En esta tesis se evalúan diferentes catalizadores para la reacción de alquilación de isobutano con olefinas. Se estudian zeolitas microporosas, Y, X, Beta y Mordenita. Estos materiales presentan diferentes relaciones Si/Al y la regulación de acidez se realiza mediante intercambio iónico con La+3 y/o NH4+. Se presenta también el diseño de catalizadores mesoporosos, estudiándose sílices SBA-15 funcionalizadas con grupos sulfónicos. Los materiales microporosos con niveles de acidez moderados son...

  2. Cd{sub 1−x}Zn{sub x}S thin films with low Zn content obtained by an ammonia-free chemical bath deposition process

    Energy Technology Data Exchange (ETDEWEB)

    Carreón-Moncada, I. [Centro de Investigación y de Estudios Avanzados del IPN, Unidad Saltillo, Av. Industria Metalúrgica 1062, CP. 25900, Ramos Arizpe, Coah., México (Mexico); González, L.A., E-mail: luis.gonzalez@cinvestav.edu.mx [Centro de Investigación y de Estudios Avanzados del IPN, Unidad Saltillo, Av. Industria Metalúrgica 1062, CP. 25900, Ramos Arizpe, Coah., México (Mexico); Pech-Canul, M.I. [Centro de Investigación y de Estudios Avanzados del IPN, Unidad Saltillo, Av. Industria Metalúrgica 1062, CP. 25900, Ramos Arizpe, Coah., México (Mexico); Ramírez-Bon, R. [Centro de Investigación y de Estudios Avanzados del IPN, Unidad Querétaro, Apartado Postal 1-798, CP. 76001 Querétaro, Qro., México (Mexico)

    2013-12-02

    Cd{sub 1−x}Zn{sub x}S films with low Zn content were obtained on glass substrates by an ammonia-free chemical bath deposition process. Alkaline reaction solutions were prepared using cadmium chloride, zinc chloride, sodium citrate, thiourea and potassium hydroxide. As a result of varying the mixture ratio between Cd and Zn precursors, microstructural studies from X-ray diffraction reveal that the resulting films have hexagonal, wurzite type, crystalline structure with changes in the preferential growth orientation. Important changes on the surface morphology and thickness of the Cd{sub 1−x}Zn{sub x}S films were also observed as effects of adding Zn to the CdS lattice. Optical studies show that Cd{sub 1−x}Zn{sub x}S thin films with energy band gaps in the range from 2.48 to 2.65 eV were obtained. - Highlights: • Cd{sub 1−x}Zn{sub x}S layers were grown on glass by ammonia-free chemical bath deposition • Films with low Zn content were obtained using reaction solutions with pH11.5 • Zn addition produced changes on the orientation growth and morphology of the films • Cd{sub 1−x}Zn{sub x}S films have energy band gap values from 2.48 to 2.65 eV.

  3. APLIKASI ANALYTIC NETWORK PROCESS (ANP PADA PERANCANGAN SISTEM PENGUKURAN KINERJA (Studi Kasus pada PT. X

    Directory of Open Access Journals (Sweden)

    Iwan Vanany

    2003-01-01

    Full Text Available The paper discusses the application of Analytic Network Process (ANP to support the weighted of design performance measurement system with Balanced Scorecard method. During the time, the weighted uses method that disregarding interdependence between objectives strategy and Key Performance Indicator (KPI's. The method which often used in this weighted is Analytical Hierarchy Process (AHP. In fact this condition does not express the concept of strategy map of Balanced Scorecard. Therefore is needed apply the other weighted method which attention to the interdependence between Key Performance Indicator (KPI. Application of the weighted with ANP method is conducted at one of the power company. This company represents result of restructuring of PT. PLN (Persero. The result of design performance measurement system of PT. X are objective strategy, Key Performance Indicator (KPI and strategy map, will be weighted by method of ANP. Further more Modeling of ANP based on strategy map. The result of application indicates that related of model of strategy map in Balanced Scorecard at PT. X is Feedback Network (hiernet with phenomenon of inner and dependence of outer dependence. The perspective on Balanced Scorecard is identically with cluster on ANP, while objective strategy and KPI are identically with sub-element and element. Result of weighted with ANP method shows the existence of culmination of weighted on financial perspective of Strategy Map at PT. X. Abstract in Bahasa Indonesia : Makalah ini membahas aplikasi Analytic Network Process (ANP untuk mendukung pembobotan pada perancangan sistem pengukuran kinerja dengan metode Balanced Scorecard. Selama ini, pembobotan yang ada menggunakan metode yang mengabaikan saling keterkaitan antar strategi objektif dengan Key Performance Indicator (KPI-KPI -nya. Metode yang sering digunakan didalam pembobotan ini adalah Analytical Hierarchy Process (AHP. Kondisi ini sebenarnya tidak mencerminkan konsep Strategy Map

  4. An external interface for processing 3-D holographic and X-ray images

    International Nuclear Information System (INIS)

    Jueptner, W.; Kreis, T.

    1989-01-01

    The aim of the ESPRIT project 898 is the development of an external interface system, that links physically generated 3-D images to inspection and analysis procedures. While this has to be a general and flexible system, it is used in this project for holographic interferograms and X-ray radiographs for applications in areas such as real time testing and inspection and 3-D measurment. For this task, optical and electronic methods have to be combined in order to extract the relevant information from multiple 3-D images. A further aim of the project is the automation of the holographic interferometry and the X-ray radioscopy for on-line testing in the manufacturing process. (orig./HP)

  5. Ensayo comparativo de tres catalizadores en la producción de metil parabeno

    OpenAIRE

    Haiver Galeano P.; Gerardo Rodríguez N.; Nelson Correa G.; Luis A. Caicedo

    2011-01-01

    En este artículo se presenta un estudio experimental para la producción de metil parabeno, se analiza la influencia del tipo y la cantidad de catalizador así como la relación molar en la mezcla reaccionante para esta reacción de esterificación. Se estudian como catalizadores el ácido sulfúrico y dos resinas de intercambio iónico, siendo el ácido sulfúrico el que muestra mayores rendimientos.

  6. Bayesian soft X-ray tomography using non-stationary Gaussian Processes

    International Nuclear Information System (INIS)

    Li, Dong; Svensson, J.; Thomsen, H.; Werner, A.; Wolf, R.; Medina, F.

    2013-01-01

    In this study, a Bayesian based non-stationary Gaussian Process (GP) method for the inference of soft X-ray emissivity distribution along with its associated uncertainties has been developed. For the investigation of equilibrium condition and fast magnetohydrodynamic behaviors in nuclear fusion plasmas, it is of importance to infer, especially in the plasma center, spatially resolved soft X-ray profiles from a limited number of noisy line integral measurements. For this ill-posed inversion problem, Bayesian probability theory can provide a posterior probability distribution over all possible solutions under given model assumptions. Specifically, the use of a non-stationary GP to model the emission allows the model to adapt to the varying length scales of the underlying diffusion process. In contrast to other conventional methods, the prior regularization is realized in a probability form which enhances the capability of uncertainty analysis, in consequence, scientists who concern the reliability of their results will benefit from it. Under the assumption of normally distributed noise, the posterior distribution evaluated at a discrete number of points becomes a multivariate normal distribution whose mean and covariance are analytically available, making inversions and calculation of uncertainty fast. Additionally, the hyper-parameters embedded in the model assumption can be optimized through a Bayesian Occam's Razor formalism and thereby automatically adjust the model complexity. This method is shown to produce convincing reconstructions and good agreements with independently calculated results from the Maximum Entropy and Equilibrium-Based Iterative Tomography Algorithm methods

  7. Bayesian soft X-ray tomography using non-stationary Gaussian Processes

    Science.gov (United States)

    Li, Dong; Svensson, J.; Thomsen, H.; Medina, F.; Werner, A.; Wolf, R.

    2013-08-01

    In this study, a Bayesian based non-stationary Gaussian Process (GP) method for the inference of soft X-ray emissivity distribution along with its associated uncertainties has been developed. For the investigation of equilibrium condition and fast magnetohydrodynamic behaviors in nuclear fusion plasmas, it is of importance to infer, especially in the plasma center, spatially resolved soft X-ray profiles from a limited number of noisy line integral measurements. For this ill-posed inversion problem, Bayesian probability theory can provide a posterior probability distribution over all possible solutions under given model assumptions. Specifically, the use of a non-stationary GP to model the emission allows the model to adapt to the varying length scales of the underlying diffusion process. In contrast to other conventional methods, the prior regularization is realized in a probability form which enhances the capability of uncertainty analysis, in consequence, scientists who concern the reliability of their results will benefit from it. Under the assumption of normally distributed noise, the posterior distribution evaluated at a discrete number of points becomes a multivariate normal distribution whose mean and covariance are analytically available, making inversions and calculation of uncertainty fast. Additionally, the hyper-parameters embedded in the model assumption can be optimized through a Bayesian Occam's Razor formalism and thereby automatically adjust the model complexity. This method is shown to produce convincing reconstructions and good agreements with independently calculated results from the Maximum Entropy and Equilibrium-Based Iterative Tomography Algorithm methods.

  8. Recipe Book for Larger Benthic Foraminifera X-ray Investigation: a Process Approach

    Science.gov (United States)

    Wolfgring, E.; Briguglio, A.; Hohenegger, J.

    2012-04-01

    During the past years X-ray microtomography (microCT) has become an essential tool in imaging procedures in micropaleontology. Apart from highest standards in accuracy, well conducted microCT scans aim to resolve the whole specimen in constant quality and free from any artifacts or visual interferences. Normally, to get used to X-ray techniques and get usable results, countless attempts are needed, resulting in enormous waste of time. This work tries to provide an insight into how best exploitable results can be obtained from the scanning process concerning Larger Benthic Foraminifera (LBF). As each specimen features different characteristics regarding substantial composition, density and conservation status, it is impossible and probably erroneous to give standardized guidelines even within this systematic group. Depending on the attributes of the specimen and on the desired visualization, several details have to be taken into account. Samples preparation: to get sharp images the X-ray has to cross the specimen along its shortest diameter, for LBF the equatorial view is almost always the best positioning (not for alveolinids!). The container itself has to be chosen wisely as well; it must not affect a flawless penetration of the specimen by the X-ray and has to provide a high degree of stability. Small plastic pipettes are perfect to store the specimen (or specimens) and some cardboard may help in keeping the position. The nature and quality of the paste used to fixate the object and its container are essential in ensuring a smooth rotation of the specimen which is inevitable for the consistent quality of the image and to avoid vibrations. Scan parameters: beside the correct choice of dedicated filters (which are always different depending on the working station), settings for kv, µA and resolution might have to be revised for each new object to deliver optimal results. Standard values for hyaline forms with empty chambers are normally around 80 Kv and 100 u

  9. Suitable post processing algorithms for X-ray imaging using oversampled displaced multiple images

    International Nuclear Information System (INIS)

    Thim, J; Reza, S; Nawaz, K; Norlin, B; O'Nils, M; Oelmann, B

    2011-01-01

    X-ray imaging systems such as photon counting pixel detectors have a limited spatial resolution of the pixels, based on the complexity and processing technology of the readout electronics. For X-ray imaging situations where the features of interest are smaller than the imaging system pixel size, and the pixel size cannot be made smaller in the hardware, alternative means of resolution enhancement require to be considered. Oversampling with the usage of multiple displaced images, where the pixels of all images are mapped to a final resolution enhanced image, has proven a viable method of reaching a sub-pixel resolution exceeding the original resolution. The effectiveness of the oversampling method declines with the number of images taken, the sub-pixel resolution increases, but relative to a real reduction of imaging pixel sizes yielding a full resolution image, the perceived resolution from the sub-pixel oversampled image is lower. This is because the oversampling method introduces blurring noise into the mapped final images, and the blurring relative to full resolution images increases with the oversampling factor. One way of increasing the performance of the oversampling method is by sharpening the images in post processing. This paper focus on characterizing the performance increase of the oversampling method after the use of some suitable post processing filters, for digital X-ray images specifically. The results show that spatial domain filters and frequency domain filters of the same type yield indistinguishable results, which is to be expected. The results also show that the effectiveness of applying sharpening filters to oversampled multiple images increase with the number of images used (oversampling factor), leaving 60-80% of the original blurring noise after filtering a 6 x 6 mapped image (36 images taken), where the percentage is depending on the type of filter. This means that the effectiveness of the oversampling itself increase by using sharpening

  10. Autopsy on an RF-Processed X-band Travelling Wave Structure

    International Nuclear Information System (INIS)

    Le Pimpec, Frederic

    2002-01-01

    In an effort to locate the cause(s) of high electric-field breakdown in x-band accelerating structures, we have cleanly-autopsied (no debris added by post-operation structure disassembly) an RF-processed structure. Macroscopic localization provided operationally by RF reflected wave analysis and acoustic sensor pickup was used to connect breakdowns to autopsied crater damage areas. Surprisingly, the microscopic analyses showed breakdown craters in areas of low electric field. High currents induced by the magnetic field on sharp corners of the input coupler appears responsible for the extreme breakdown damage observed

  11. Exploitation of a self-limiting process for reproducible formation of ultrathin Ni1-xPtx silicide films

    International Nuclear Information System (INIS)

    Zhang Zhen; Zhu Yu; Rossnagel, Steve; Murray, Conal; Jordan-Sweet, Jean; Yang, Bin; Gaudet, Simon; Desjardins, Patrick; Kellock, Andrew J.; Ozcan, Ahmet; Zhang Shili; Lavoie, Christian

    2010-01-01

    This letter reports on a process scheme to obtain highly reproducible Ni 1-x Pt x silicide films of 3-6 nm thickness formed on a Si(100) substrate. Such ultrathin silicide films are readily attained by sputter deposition of metal films, metal stripping in wet chemicals, and final silicidation by rapid thermal processing. This process sequence warrants an invariant amount of metal intermixed with Si in the substrate surface region independent of the initial metal thickness, thereby leading to a self-limiting formation of ultrathin silicide films. The crystallographic structure, thickness, uniformity, and morphological stability of the final silicide films depend sensitively on the initial Pt fraction.

  12. Energetic electron processes fluorescence effects for structured nanoparticles X-ray analysis and nuclear medicine applications

    Energy Technology Data Exchange (ETDEWEB)

    Taborda, A.; Desbrée, A. [Institut de Radioprotection et de Sûreté Nucléaire (IRSN), PRP-HOM/SDI/LEDI, BP-17, 31, Avenue de la Division Leclerc, 92262 Fontenay-aux-Roses (France); Carvalho, A. [IEQUALTECS, Lda, Rua Dr. Francisco Sá Carneiro, 36, 2500-065 S. Gregório CLD (Portugal); Chaves, P.C. [C" 2TN, Campus Tecnológico e Nuclear, Instituto Superior Técnico, Universidade de Lisboa, EN10 km 139.7, 2685-066 Bobadela LRS (Portugal); Reis, M.A., E-mail: mareis@ctn.tecnico.ulisboa.pt [IEQUALTECS, Lda, Rua Dr. Francisco Sá Carneiro, 36, 2500-065 S. Gregório CLD (Portugal); C" 2TN, Campus Tecnológico e Nuclear, Instituto Superior Técnico, Universidade de Lisboa, EN10 km 139.7, 2685-066 Bobadela LRS (Portugal)

    2016-08-15

    Superparamagnetic iron oxide (SPIO) nanoparticles are widely used as contrast agents for nuclear magnetic resonance imaging (MRI), and can be modified for improved imaging or to become tissue-specific or even protein-specific. The knowledge of their detailed elemental composition characterisation and potential use in nuclear medicine applications, is, therefore, an important issue. X-ray fluorescence techniques such as particle induced X-ray emission (PIXE) or X-ray fluorescence spectrometry (XRF), can be used for elemental characterisation even in problematic situations where very little sample volume is available. Still, the fluorescence coefficient of Fe is such that, during the decay of the inner-shell ionised atomic structure, keV Auger electrons are produced in excess to X-rays. Since cross-sections for ionisation induced by keV electrons, for low atomic number atoms, are of the order of 10{sup 3} barn, care should be taken to account for possible fluorescence effects caused by Auger electrons, which may lead to the wrong quantification of elements having atomic number lower than the atomic number of Fe. Furthermore, the same electron processes will occur in iron oxide nanoparticles containing {sup 57}Co, which may be used for nuclear medicine therapy purposes. In the present work, simple approximation algorithms are proposed for the quantitative description of radiative and non-radiative processes associated with Auger electrons cascades. The effects on analytical processes and nuclear medicine applications are quantified for the case of iron oxide nanoparticles, by calculating both electron fluorescence emissions and energy deposition on cell tissues where the nanoparticles may be embedded.

  13. Interactive processing of x-ray diffraction maxima (exchange of experience)

    International Nuclear Information System (INIS)

    Zabolotnyi, V.A.; Moroz, E.M.

    1993-01-01

    A program package for primary processing of the curve of intensity of x-ray dispersion has been developed and tested within the framework of creating computer programs that are compatible with IBM/PC/XT/AT computers for calculation and modeling of randial distributions of atoms. The following calculations have been included in this package: determination of the positions of maxima; separation of the maxima; and calculation of the integral characteristics of components. This paper describes the main feature of the algorithm, which is the procedure for varying the form of components, each of which is represented as a sum of two Gaussians with differing half-width ad amplitude. Use of the described method of modeling of the x-ray diffraction maximum was found effective in most of the practically important cases. To illustrate the operation of the program the results of approximation of a pentaplet of quartz obtained in CuKα-radiation with 0.01 degrees scanning step and 20 sec build-up time (40 kV; 40 mA; HZG-4C) are presented. 3 refs., 2 figs., 1 tab

  14. Antimony assisted low-temperature processing of CuIn{sub 1-x}Ga{sub x}Se{sub 2-y}S{sub y} solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Min, Yuan [IBM T. J. Watson Research Center, P. O. Box 218, Yorktown Heights, NY 10598 (United States); Mitzi, David B., E-mail: dmitzi@us.ibm.co [IBM T. J. Watson Research Center, P. O. Box 218, Yorktown Heights, NY 10598 (United States); Gunawan, Oki [IBM T. J. Watson Research Center, P. O. Box 218, Yorktown Heights, NY 10598 (United States); Kellock, Andrew J [IBM Almaden Research Center, 650 Harry Rd, San Jose, CA 95120 (United States); Chey, S Jay [IBM T. J. Watson Research Center, P. O. Box 218, Yorktown Heights, NY 10598 (United States); Deline, Vaughn R [IBM Almaden Research Center, 650 Harry Rd, San Jose, CA 95120 (United States)

    2010-11-01

    Application of the Sb-doping method to low-temperature ({<=} 400 {sup o}C) processing of CuIn{sub 1-x}Ga{sub x}Se{sub 2-y}S{sub y} (CIGS) solar cells is explored, using a hydrazine-based approach to deposit the absorber films. Power conversion efficiencies of 10.5% and 8.4% have been achieved for CIGS devices (0.45 cm{sup 2} device area) processed at 400 {sup o}C and 360 {sup o}C, respectively, with an Sb-incorporation level at 1.2 mol % (relative to the moles of CIGS). Significant Sb-induced grain size enhancement was confirmed for these low processing temperatures using cross-sectional scanning electron microscopy, and an average 2-3% absolute efficiency improvement was achieved in Sb-doped samples compared to their Sb-free sister samples. With Sb inclusion, the CIGS film grain growth temperature is lowered to well below 450 {sup o}C, a range compatible with flexible polymer substrate materials such as polyimide. This method opens up access to opportunities in low-temperature processing of CIGS solar cells, an area that is being actively pursued using both traditional vacuum-based as well as other solution-based deposition techniques.

  15. Rapid thermal processing chamber for in-situ x-ray diffraction

    International Nuclear Information System (INIS)

    Ahmad, Md. Imteyaz; Van Campen, Douglas G.; Yu, Jiafan; Pool, Vanessa L.; Van Hest, Maikel F. A. M.; Toney, Michael F.; Fields, Jeremy D.; Parilla, Philip A.; Ginley, David S.

    2015-01-01

    Rapid thermal processing (RTP) is widely used for processing a variety of materials, including electronics and photovoltaics. Presently, optimization of RTP is done primarily based on ex-situ studies. As a consequence, the precise reaction pathways and phase progression during the RTP remain unclear. More awareness of the reaction pathways would better enable process optimization and foster increased adoption of RTP, which offers numerous advantages for synthesis of a broad range of materials systems. To achieve this, we have designed and developed a RTP instrument that enables real-time collection of X-ray diffraction data with intervals as short as 100 ms, while heating with ramp rates up to 100 °Cs −1 , and with a maximum operating temperature of 1200 °C. The system is portable and can be installed on a synchrotron beamline. The unique capabilities of this instrument are demonstrated with in-situ characterization of a Bi 2 O 3 -SiO 2 glass frit obtained during heating with ramp rates 5 °C s −1 and 100 °C s −1 , revealing numerous phase changes

  16. Ensayo comparativo de tres catalizadores en la producción de metil parabeno

    Directory of Open Access Journals (Sweden)

    Haiver Galeano P.

    1996-09-01

    Full Text Available En este artículo se presenta un estudio experimental para la producción de metil parabeno, se analiza la influencia del tipo y la cantidad de catalizador así como la relación molar en la mezcla reaccionante para esta reacción de esterificación. Se estudian como catalizadores el ácido sulfúrico y dos resinas de intercambio iónico, siendo el ácido sulfúrico el que muestra mayores rendimientos.

  17. Study of caprine bones after moist and dry heat processes by X-ray diffraction

    International Nuclear Information System (INIS)

    Barbosa, Caroline M.; Azeredo, Soraia R.; Lopes, Ricardo T.; Souza, Sheila M.F.M de

    2013-01-01

    Bone tissue is a biological material composed of hydroxyapatite (HAp) and collagen matrix. The bone X-ray diffraction (XRD) pattern presents characteristics of the hydroxyapatite crystallography planes. This paper presents the characterization by X-ray diffraction of caprine bone powder pattern and the comparison of this pattern with moist or dry heat cooked bone patterns. The parameters chosen to characterize the X-ray diffraction peaks were: angular position (2θ), full width at half maximumt (FWHM), and relative intensity (I rel ). The X-ray diffraction patterns were obtained with a Shimadzu XRD-6000 diffractometer. The caprine bone XRD pattern revealed a significant correlation of several crystallographic parameters (lattice data) with hydroxyapatite. The profiles of the three bone types analyzed presented differences. The study showed as small angular displacement (decrease of the 2θ angle) of some peaks was observed after moist and dry heat cooking processes. The characterization of bone tissue aimed to contribute to future analysis in the field of archeology. (author)

  18. Study of caprine bones after moist and dry heat processes by X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, Caroline M., E-mail: carolmattosb@yahoo.com.br [Instituto de Arqueologia Brasileira (IAB), Belford Roxo, RJ (Brazil); Azeredo, Soraia R.; Lopes, Ricardo T., E-mail: soraia@lin.ufrj.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/LIN/UFRJ), Rio de Janeiro, RJ (Brazil). Laboratorio de Instrumentacao Nuclear; Souza, Sheila M.F.M de, E-mail: sferraz@ensp.fiocruz.br [Fundacao Oswaldo Cruz (ENSP/FIOCRUZ), Rio de Janeiro, RJ (Brazil). Escola Nacional de Saude Publica Sergio Arouca

    2013-07-01

    Bone tissue is a biological material composed of hydroxyapatite (HAp) and collagen matrix. The bone X-ray diffraction (XRD) pattern presents characteristics of the hydroxyapatite crystallography planes. This paper presents the characterization by X-ray diffraction of caprine bone powder pattern and the comparison of this pattern with moist or dry heat cooked bone patterns. The parameters chosen to characterize the X-ray diffraction peaks were: angular position (2θ), full width at half maximumt (FWHM), and relative intensity (I{sub rel}). The X-ray diffraction patterns were obtained with a Shimadzu XRD-6000 diffractometer. The caprine bone XRD pattern revealed a significant correlation of several crystallographic parameters (lattice data) with hydroxyapatite. The profiles of the three bone types analyzed presented differences. The study showed as small angular displacement (decrease of the 2θ angle) of some peaks was observed after moist and dry heat cooking processes. The characterization of bone tissue aimed to contribute to future analysis in the field of archeology. (author)

  19. Microwave-induced combustion synthesis and electrical conductivity of Ce1-xGd xO2-1/2x ceramics

    International Nuclear Information System (INIS)

    Fu, Y.-P.; Chang, Y.-S.; Wen, S.-B.

    2006-01-01

    Ce 1-x Gd x O 2-1/2x nanopowder were successfully synthesized by microwave-induced combustion process. For the preparation, cerium nitrate, gadolinium nitrate hexahydrate, and urea were used for the microwave-induced combustion process. The process took only 30 min to obtain Ce 1-x Gd x O 2-1/2x powders. The exo-endo temperature, phase identification, and morphology of resultant powders were investigated by TG/DTA, XRD, and SEM. The as-received Ce 1-x Gd x O 2-1/2x powders showed that the average particle size ranged from 18 to 50 nm, crystallite dimension varied from 11 to 20 nm, and the specific surface area was distribution from 16 to 46 m 2 /g. As for Ce 1-x Gd x O 2-1/2x ceramics sintered at 1450 deg. C for 3 h, the bulk density of Ce 1-x Gd x O 2-1/2x ceramics were over 91% of the theoretical density, the maximum electrical conductivity, σ 700deg.C = 0.017 S/cm with minimum activation energy, E a = 0.869 eV was found at Ce 0.80 Gd 0.20 O 1.90 ceramic

  20. Quality assessment of the digitalization process of analog x-ray images

    International Nuclear Information System (INIS)

    Georgieva, D.

    2014-01-01

    Computer-assisted diagnosis enabled doctors for a second point-of-view on the test results. This improves the diseases' early detection and significantly reduces the chance of errors. These methods very nicely complemented the possibilities of digital medical imaging apparatus, but in analog images their applicability and results entirely depend on the quality of analog images digitalisation. Today many standards and remarks for good practices discuss the digital apparatus image quality but the digitalisation process of analog medical images is not a part of them. Medical imaging apparatus have become digital, but within an entirely digital medical environment is necessary for their ability to blend with the old analog medical imaging carriers. The life of patients doesn't start with the beginning of digital era and for the aim of tracking diseases it is necessary to use the new digital images as well as older analog ones. For the generation of 40-50 years a large archive of images is piled up, which should be accounted of in the diagnosis process. This article is the author's study of the digitalized image quality problem. It offers a new approach to the x-ray image digitalisation - getting the HDR-image by optical sensor. After the HDR-image generation method offers to be used a digital signal processing to improve the quality of the final 16 bit gray scale medical image. The new method for medical image enhancement is proposed - it improves the image contrast, it increases or preserves the dynamic range and it doesn't lead to the loss of small low contrast structures in the image. Key words: Quality of Digital X-Rays Images

  1. Fabrication of Cu{sub 2}ZnSn(S{sub x}Se{sub 1−x}){sub 4} solar cells by ethanol-ammonium solution process

    Energy Technology Data Exchange (ETDEWEB)

    Xue, Cong; Li, Jianmin; Wang, Yaguang; Jiang, Guoshun; Weifeng, Liu, E-mail: liuwf@ustc.edu.cn; Zhu, Changfei, E-mail: cfzhu@ustc.edu.cn

    2016-10-15

    Highlights: • The CBD precipitates were utilized to fabricate the CZTS/CZTSSe solar cells. • A solvent mixture of ethanol and ammonium hydroxide was used to form SnS-Cu2O-ZnS slurry. • Formation of CZTS/CZTSSe with good crystalline quality confirmed by XRD and Raman spectra. • CZTS and CZTSSe thin film solar cells obtained the best PCE of 1.99% and 2.95%, respectively. - Abstract: In this paper, Cu{sub 2}ZnSn(S{sub x}Se{sub 1−x}){sub 4} precursor films were produced by doctor blade process from SnS-Cu{sub 2}O-ZnS slurry. To prepare the slurry, SnS, ZnS and Cu{sub 2}O precipitates, which are outgrowths of stacked layer ZnS/Cu/SnS by CBD (chemical bath deposition)-annealing route, were dissolved in the mixture solvent of ethanol and NH{sub 3}·H{sub 2}O. Synthesized precursor films were then annealed at different conditions. The post-annealed films were characterized by means of scanning electron microscopy (SEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), Raman measurements and UV–vis–NIR spectroscopy. SEM studies reveal that the rough and relatively compact absorber thin films are obtained via the sulfidation and sulfidation-selenization processes. X-ray diffraction and Raman spectrum results verify that the obtained films are composed of Cu{sub 2}ZnSnS{sub 4} and Cu{sub 2}ZnSnSe{sub 4} phases, which have high absorbance in visible range and direct band gap energy of 1.01–1.47 eV. The best devices yield total area power conversion efficiency of 1.99% and 2.95% corresponding to Cu{sub 2}ZnSnS{sub 4} and Cu{sub 2}ZnSn(S{sub x}Se{sub 1−x}){sub 4} thin film solar cells under AM1.5 illumination without any anti-reflection layer.

  2. A reengineering success story: process improvement in emergency department x-ray cycle time, leading to breakthrough performance in the ED ambulatory care (Fast Track) process.

    Science.gov (United States)

    Espinosa, J A; Treiber, P M; Kosnik, L

    1997-01-01

    This article describes the journey of a multidisciplinary reengineering team, which worked to reduce a critical, high-leverage process in an emergency department setting. The process selected was emergency department radiology services. This process was selected on a rational basis. The team knew tht 60 percent of our emergency department patients were truly ambulatory, and that most could be seen in a "fast track" process as part of our emergency department's core mission. However, we knew from customer satisfaction data, that patients would like to be "in and out" of emergency department Fast Track in less than an hour. Over half of our Fast Track patients require x-rays. For most, this was their sole reason for seeking emergency care. Our state, at the start of the project, included an average x-ray cycle time of over 60 minutes. The associated Fast-Track cycle time was over 90 minutes median. It was clear to the emergency department leadership, as well as to members of the Fast-Track management team, that a cycle time of 30 minutes or less for x-ray service was needed as a necessary condition to an hour or less Fast Track cycle time. It was also felt that a more rapid x-ray cycle time would allow for more rapid turn over of ED rooms, leading to a virtual greater capacity to the ED. It was hoped that this would lead to a reduction in the time from arrival to treatment by the emergency physician for all patients.

  3. Microstructure and Properties of Fe3Al-Fe3AlC x Composite Prepared by Reactive Liquid Processing

    Science.gov (United States)

    Verona, Maria Nalu; Setti, Dalmarino; Paredes, Ramón Sigifredo Cortés

    2018-04-01

    A Fe3Al-Fe3AlC x composite was prepared using reactive liquid processing (RLP) through controlled mixture of carbon steel and aluminum in the liquid state. The microstructure and phases of the composite were assessed using X-ray diffraction, scanning electron microscopy, energy-dispersive X-ray spectroscopy, optical microscopy, and differential scanning calorimetry. In addition, the density, hardness, microhardness, and elastic modulus were evaluated. The Fe3Al-Fe3AlC x composite consisted of 65 vol pct Fe3Al and 35 vol pct Fe3AlC x ( κ). The κ phase contained 10.62 at. pct C, resulting in the stoichiometry Fe3AlC0.475. The elastic modulus of the Fe3Al-Fe3AlC0.475 composite followed the rule of mixtures. The RLP technique was shown to be capable of producing Fe3Al-Fe3AlC0.475 with a microstructure and properties similar to those achieved using other processing techniques reported in the literature.

  4. High-Performance Parallel and Stream Processing of X-ray Microdiffraction Data on Multicores

    International Nuclear Information System (INIS)

    Bauer, Michael A; McIntyre, Stewart; Xie Yuzhen; Biem, Alain; Tamura, Nobumichi

    2012-01-01

    We present the design and implementation of a high-performance system for processing synchrotron X-ray microdiffraction (XRD) data in IBM InfoSphere Streams on multicore processors. We report on the parallel and stream processing techniques that we use to harvest the power of clusters of multicores to analyze hundreds of gigabytes of synchrotron XRD data in order to reveal the microtexture of polycrystalline materials. The timing to process one XRD image using one pipeline is about ten times faster than the best C program at present. With the support of InfoSphere Streams platform, our software is able to be scaled up to operate on clusters of multi-cores for processing multiple images concurrently. This system provides a high-performance processing kernel to achieve near real-time data analysis of image data from synchrotron experiments.

  5. Complete O(α) QED corrections to the process ep→eX in mixed variables

    International Nuclear Information System (INIS)

    Bardin, D.; Joint Inst. of Nuclear Research, Moscow; Christova, P.; Kalinovskaya, L.; Riemann, T.

    1995-04-01

    The complete set of OMIKRON (α) QED corrections with soft photon exponentiation to the process ep→eX in mixed variables (y=y h , Q 2 =Q l 2 ) is calculated in the quark parton model. Compared to earlier attempts, we additionally determine the lepton-quark interference and the quarkonic corrections. The net results are compared to the approximation with only leptonic corrections, which amount to several percent (at large x or y: several dozens of percents). We find that the newly calculated corrections modify this by few percent or less and become negligible at small y. (orig.)

  6. Rapid thermal processing chamber for in-situ x-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, Md. Imteyaz; Van Campen, Douglas G.; Yu, Jiafan; Pool, Vanessa L.; Van Hest, Maikel F. A. M.; Toney, Michael F., E-mail: mftoney@slac.stanford.edu [SSRL, SLAC National Accelerator Laboratory, 2575, Sand Hill Road, Menlo Park, California 94025 (United States); Fields, Jeremy D.; Parilla, Philip A.; Ginley, David S. [National Renewable Energy Laboratory, Golden, Colorado 80401 (United States)

    2015-01-15

    Rapid thermal processing (RTP) is widely used for processing a variety of materials, including electronics and photovoltaics. Presently, optimization of RTP is done primarily based on ex-situ studies. As a consequence, the precise reaction pathways and phase progression during the RTP remain unclear. More awareness of the reaction pathways would better enable process optimization and foster increased adoption of RTP, which offers numerous advantages for synthesis of a broad range of materials systems. To achieve this, we have designed and developed a RTP instrument that enables real-time collection of X-ray diffraction data with intervals as short as 100 ms, while heating with ramp rates up to 100 °Cs{sup −1}, and with a maximum operating temperature of 1200 °C. The system is portable and can be installed on a synchrotron beamline. The unique capabilities of this instrument are demonstrated with in-situ characterization of a Bi{sub 2}O{sub 3}-SiO{sub 2} glass frit obtained during heating with ramp rates 5 °C s{sup −1} and 100 °C s{sup −1}, revealing numerous phase changes.

  7. Colloidal processing and CO_2-capture performance Al_2O_3-zeolite 13X composites

    International Nuclear Information System (INIS)

    Andersson, L.; Akhtar, F.; Ojuva, A.; Bergstroem, L.

    2012-01-01

    Hierarchically porous composites for CO_2-capture have been produced by coating the inner walls of foam-like macroporous alumina monoliths, produced by templated synthesis, with microporous zeolite 13X particles. Homogeneous and dense coatings of the particulate adsorbent were obtained when the impregnation process was performed at a pH above 9. At this pH-level the colloidally stable suspensions of the negatively charged zeolite 13X particles could fill all the voids of the highly connected pore space of the alumina supports and attach to the monolith walls, which had been pre-coated with poly(ethylene imine). A CO_2-uptake as high as 5 mmol CO_2/g zeolite 13X was achieved for alumina-zeolite 13X composites through minimisation of the added inorganic binder, kaolin, to only 3.0 wt% with respect to zeolite content, and through optimisation of the thermal treatment.

  8. A Comprehensive Study of One-Step Selenization Process for Cu(In1-x Ga x )Se2 Thin Film Solar Cells.

    Science.gov (United States)

    Chen, Shih-Chen; Wang, Sheng-Wen; Kuo, Shou-Yi; Juang, Jenh-Yih; Lee, Po-Tsung; Luo, Chih Wei; Wu, Kaung-Hsiung; Kuo, Hao-Chung

    2017-12-01

    In this work, aiming at developing a rapid and environmental-friendly process for fabricating CuIn 1-x Ga x Se 2 (CIGS) solar cells, we demonstrated the one-step selenization process by using selenium vapor as the atmospheric gas instead of the commonly used H 2 Se gas. The photoluminescence (PL) characteristics indicate that there exists an optimal location with superior crystalline quality in the CIGS thin films obtained by one-step selenization. The energy dispersive spectroscopy (EDS) reveals that the Ga lateral distribution in the one-step selenized CIGS thin film is intimately correlated to the blue-shifted PL spectra. The surface morphologies examined by scanning electron microscope (SEM) further suggested that voids and binary phase commonly existing in CIGS films could be successfully eliminated by the present one-step selenization process. The agglomeration phenomenon attributable to the formation of MoSe 2 layer was also observed. Due to the significant microstructural improvement, the current-voltage (J-V) characteristics and external quantum efficiency (EQE) of the devices made of the present CIGS films have exhibited the remarkable carrier transportation characteristics and photon utilization at the optimal location, resulting in a high conversion efficiency of 11.28%. Correlations between the defect states and device performance of the one-step selenized CIGS thin film were convincingly delineated by femtosecond pump-probe spectroscopy.

  9. Solution processing of YBa2Cu3O7-x thin films

    International Nuclear Information System (INIS)

    Singhal, A.; Paranthaman, M.; Specht, E.D.; Hunt, R.D.; Beach, D.B.; Martin, P.M.; Lee, D.F.

    1997-12-01

    The aim of this work was to develop a non-vacuum chemical deposition technique for YBa 2 Cu 3 O 7-x (YBCO) coated conductors on rolling-assisted biaxially textured substrates (RABiTS). The authors have chosen the metal-organic decomposition (MOD) and sol-gel precursor routes to grow textured YBCO films. In the MOD process, yttrium 2-ethylhexonate, barium neodecanoate, copper 2-ethylhexonate and toluene were used as the starting reagents. YBCO films processed by the MOD method on SrTiO 3 (100) single crystal substrates were consisted of c and a-axis oriented materials. These films also contained some amount of the random phase. The c and a-axis oriented materials were epitaxial on SrTiO 3 substrates. Films have a T c,onset of 89K and the best superconducting transition temperature of 63K. Films pyrolyzed at 525 C and subsequently annealed at 780 C in a p(O 2 ) of 3.5 x 10 -4 atm contained YBCO phase predominantly in a-axis orientation. In the sol-gel route, yttrium-isopropoxide, barium metal, copper methoxide and 2-methoxyethanol were used as the starting reagents. Sol-gel YBCO films on SrTiO 3 substrates were epitaxial and c-axis oriented

  10. Interplay of hard and soft physics in small x deep inelastic processes

    International Nuclear Information System (INIS)

    Abramowicz, H.

    1995-01-01

    Coherence phenomena, the increase with energy of coherence length and the nonuniversality of parton structure of the effective pomeron are explained. New hard phenomena directly calculable in QCD such as diffractive electroproduction of states with M 2 2 and the color transparency phenomenon as well as new options to measure the light-cone wave functions of various hadrons are considered. An analogue of Bjorken scaling is predicted for the diffractive electroproduction of ρ mesons at large momentum transfers and for the production of large rapidity gap events, as observed at HERA. A phenomenological QCD evolution equation is suggested to calculate the basic characteristics of the large rapidity gap events. The increase of parton densities at small x as well as new means to disentangle experimentally soft and hard physics are considered. We discuss constraints on the increase of deep inelastic amplitudes with Q 2 derived from the inconsistency of QCD predictions for inclusive and exclusive processes and from unitarity of the S matrix for collisions of wave packets. New ways to probe QCD physics of hard processes at large longitudinal distances and to answer the long standing problems on the origin of the pomeron are suggested. Unresolved problems and perspectives of small x physics are also outlined. (orig.)

  11. Investigation of inclusive processes π-A → π-X and πsup(-)A → Psub(backwards)X at 40 GeV/c

    International Nuclear Information System (INIS)

    Abrosimov, A.T.

    1984-01-01

    The study of the inclusive processe is peformed for nuclear targets: C, Al, Cu, Pb t 40 GeV/c. Inclusive spectra of negative pions are obtained in the region 0.1 - A → Psub(backward)X is studied in the 0.3-1 GeV/c region of secondary protons. Invariant cross sections of proton flying out in the back hemisphere are measured for the 120 deg - 175 deg angle interval. The A-dependece of the invariant cross section for this process is discussed

  12. Devices, materials, and processes for nano-electronics: characterization with advanced X-ray techniques using lab-based and synchrotron radiation sources

    International Nuclear Information System (INIS)

    Zschech, E.; Wyon, C.; Murray, C.E.; Schneider, G.

    2011-01-01

    Future nano-electronics manufacturing at extraordinary length scales, new device structures, and advanced materials will provide challenges to process development and engineering but also to process control and physical failure analysis. Advanced X-ray techniques, using lab systems and synchrotron radiation sources, will play a key role for the characterization of thin films, nano-structures, surfaces, and interfaces. The development of advanced X-ray techniques and tools will reduce risk and time for the introduction of new technologies. Eventually, time-to-market for new products will be reduced by the timely implementation of the best techniques for process development and process control. The development and use of advanced methods at synchrotron radiation sources will be increasingly important, particularly for research and development in the field of advanced processes and new materials but also for the development of new X-ray components and procedures. The application of advanced X-ray techniques, in-line, in out-of-fab analytical labs and at synchrotron radiation sources, for research, development, and manufacturing in the nano-electronics industry is reviewed. The focus of this paper is on the study of nano-scale device and on-chip interconnect materials, and materials for 3D IC integration as well. (authors)

  13. 17 CFR 249.250 - Form F-X, for appointment of agent for service of process by issuers registering securities on...

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Form F-X, for appointment of agent for service of process by issuers registering securities on Form F-8, F-9, F-10 or F-80 (§ 239.38... F-X, for appointment of agent for service of process by issuers registering securities on Form F-8...

  14. Efficient and stable CH3NH3PbI3-x(SCN)x planar perovskite solar cells fabricated in ambient air with low-temperature process

    Science.gov (United States)

    Zhang, Zongbao; Zhou, Yang; Cai, Yangyang; Liu, Hui; Qin, Qiqi; Lu, Xubing; Gao, Xingsen; Shui, Lingling; Wu, Sujuan; Liu, Jun-Ming

    2018-02-01

    Planar perovskite solar cells (PSCs) based on CH3NH3PbI3-x(SCN)x (SCN: thiocyanate) active layer and low-temperature processed TiO2 films are fabricated by a sequential two-step method in ambient air. Here, alkali thiocyanates (NaSCN, KSCN) are added into Pb(SCN)2 precursor to improve the microstructure of CH3NH3PbI3-x(SCN)x perovskite layers and performance of the as-prepared PSCs. At the optimum concentrations of alkali thiocyanates as additives, the as-prepared NaSCN-modified and KSCN-modified PSCs demonstrate the efficiencies of 16.59% and 15.63% respectively, being much higher than 12.73% of the reference PSCs without additives. This improvement is primarily ascribed to the enhanced electron transport, reduced recombination rates and much improved microstructures with large grain size and low defect density at grain boundaries. Importantly, it is revealed that the modified PSCs at the optimized concentrations of alkali thiocyanates additives exhibit remarkably improved stability than the reference PSCs against humid circumstance, and a continuous exposure to humid air without encapsulation over 45 days only records about 5% degradation of the efficiency. These findings provide a facile approach to fabricate efficient and stable PSCs by low processing temperature in ambient air, both of which are highly preferred for future practical applications of PSCs.

  15. On-board event processing algorithms for a CCD-based space borne X-ray spectrometer

    International Nuclear Information System (INIS)

    Chun, H.J.; Bowles, J.A.; Branduardi-Raymont, G.; Gowen, R.A.

    1996-01-01

    This paper describes two alternative algorithms which are applied to reduce the telemetry requirements for a Charge Coupled Device (CCD) based, space-borne, X-ray spectrometer by on-board reconstruction of the X-ray events split over two or more adjacent pixels. The algorithms have been developed for the Reflection Grating Spectrometer (RGS) on the X-ray multi-mirror (XMM) mission, the second cornerstone project in the European Space Agency's Horizon 2000 programme. The overall instrument and some criteria which provide the background of the development of the algorithms, implemented in Tartan ADA on an MA31750 microprocessor, are described. The on-board processing constraints and requirements are discussed, and the performances of the algorithms are compared. Test results are presented which show that the recursive implementation is faster and has a smaller executable file although it uses more memory because of its stack requirements. (orig.)

  16. Film-based X-ray tomography combined with digital image processing: investigation of an ancient pattern-welded sword

    International Nuclear Information System (INIS)

    Lindegaard-Andersen, A.; Vedel, T.; Jeppesen, L.; Gottlieb, B.

    1988-01-01

    Film-based X-ray tomography and digital image processing have been used to investigate an inhomogeneous object of non-circular cross-section. The feasibility of using digital image processing to compensate for the poor contrast resolution inherent in film-based tomography has been demonstrated. (author)

  17. X radiation effects on the wound healing process after tooth extraction. Histological study in rats

    International Nuclear Information System (INIS)

    Miguel, R.M.; Santos Pinto, R. dos; Okamoto, T.; Santos Pinto, M.C. dos

    1988-01-01

    The X radiation effects on the wound healing process after teeth extractions are studied histologically. Albino rats are employed. After their right upper incisors were extracted, they were divided into groups of 20 animals each. With exception of the group I (control), 24 hours after teeth extractions the groups II, III and IV received X radiation, respectively, in the dosage of 75,125 and 175 R. The rats were sacrificed in group of 4, at 3, 6, 9,15 and 21 postoperative days and a histological study is done. (M.A.C.) [pt

  18. Soft X-ray magnetic scattering study of rotational magnetisation processes in cobalt/copper multilayers

    International Nuclear Information System (INIS)

    Hase, T.P.A.; Fulthorpe, B.D.; Wilkins, S.B.; Tanner, B.K.; Marrows, C.H.; Hickey, B.J.

    2001-01-01

    We report the observation of magnetic viscosity in the intensity of resonant magnetic soft X-ray scattering during rotational magnetisation processes in antiferromagnetically coupled Co/Cu multilayers. The hysteretic time-dependent component of the signal can be fitted to a single-exponential function that varies as a function of magnetising field

  19. 17 CFR 269.5 - Form F-X, for appointment of agent for service of process by issuers registering securities on...

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Form F-X, for appointment of agent for service of process by issuers registering securities on Form F-8, F-9, F-10 or F-80 (§§ 239... INDENTURE ACT OF 1939 § 269.5 Form F-X, for appointment of agent for service of process by issuers...

  20. Processing of single- and multi-domain YBa2Cu3Ox bulk materials for levitation applications by Nd1+xBa2-xCu3Oy seeding

    International Nuclear Information System (INIS)

    Todt, V.R.

    1995-01-01

    Melt processing of YBa 2 Cu 3 O x (Y123) is a well established technique to produce materials for levitation applications. We report our new results on the melt-processing of Y123. To achieve materials with high levitation forces we utilize a seeding technique using Nd 1+x Ba 2-x Cu 3 O y- seeds (Nd123). Two different kinds of Nd13-seeds, one plate-shaped and the other cube-shaped, were developed and used for this study. The microstructures of the levitators depended strongly on the type of the seeding material used and on the seeding geometry. We were able to produce large single domains as well as materials containing five domains with three different c-axis orientations. Levitation forces up to 8.2 N for samples with a diameter of about 18 mm were found for the multi-domain samples, which is well within the area of the levitation forces measured for the single domain materials

  1. X1X1X2X2/X1X2Y sex chromosome systems in the Neotropical Gymnotiformes electric fish of the genus Brachyhypopomus

    Directory of Open Access Journals (Sweden)

    Adauto Lima Cardoso

    2015-06-01

    Full Text Available Several types of sex chromosome systems have been recorded among Gymnotiformes, including male and female heterogamety, simple and multiple sex chromosomes, and different mechanisms of origin and evolution. The X1X1X2X2/X1X2Y systems identified in three species of this order are considered homoplasic for the group. In the genus Brachyhypopomus, only B. gauderio presented this type of system. Herein we describe the karyotypes of Brachyhypopomus pinnicaudatus and B. n. sp. FLAV, which have an X1X1X2X2/X1X2Y sex chromosome system that evolved via fusion between an autosome and the Y chromosome. The morphology of the chromosomes and the meiotic pairing suggest that the sex chromosomes of B. gauderio and B. pinnicaudatus have a common origin, whereas in B . n. sp. FLAV the sex chromosome system evolved independently. However, we cannot discard the possibility of common origin followed by distinct processes of differentiation. The identification of two new karyotypes with an X1X1X2X2/X1X2Y sex chromosome system in Gymnotiformes makes it the most common among the karyotyped species of the group. Comparisons of these karyotypes and the evolutionary history of the taxa indicate independent origins for their sex chromosomes systems. The recurrent emergence of the X1X1X2X2/X1X2Y system may represent sex chromosomes turnover events in Gymnotiformes.

  2. Semi-automated x-ray gauging process control system

    International Nuclear Information System (INIS)

    Draut, C.F.; Homan, D.A.

    1976-01-01

    An x-ray gauging method was developed and a production gauging system was subsequently fabricated to control the quality of precision manufactured components. The gauging system measures via x-ray absorption the density of pressed finely divided solids held in a dissimilar container. The two dissimilar materials condition necessitated a ''two scan'' technique: first, the x-ray attenuation (absorption) of the empty container prior to loading and then, the attenuation of the loaded container are measured; that is, four variables. The system provided greatly improved product control via timely data feedback and increased product quality assurance via 100 percent inspection of product. In addition, it reduced labor costs, product cost, and possibilities for human errors

  3. Visual Processing of Faces in Individuals with Fragile X Syndrome: An Eye Tracking Study

    Science.gov (United States)

    Farzin, Faraz; Rivera, Susan M.; Hessl, David

    2009-01-01

    Gaze avoidance is a hallmark behavioral feature of fragile X syndrome (FXS), but little is known about whether abnormalities in the visual processing of faces, including disrupted autonomic reactivity, may underlie this behavior. Eye tracking was used to record fixations and pupil diameter while adolescents and young adults with FXS and sex- and…

  4. Data acquisition and processing system of energy dispersive X-ray spectrometer with microprocessor

    International Nuclear Information System (INIS)

    Horkay, G.; Kis-Varga, M.; Lakatos, T.; Molnar, J.; Zsurzs, M.

    1984-01-01

    For quantitative analysis of chemical elements by the method of X-ray spectroscopy a multichannel analyzer on the base of minicomputer with the INTEL 8080 A microprocessor is developed. The data acquisition and data processing systems which comprise a central processor, memory unit, ADC and display are described. Major system subprograms are enumerated. An example of Pb concentration determinating in a bronze specimen is given

  5. Relay for the automation of the exposition process in X-ray control of material quality

    International Nuclear Information System (INIS)

    Vladimirov, L.V.; Ermakova, T.N.; Krongauz, A.N.; Kurozaev, V.P.; Khlebtsevich, V.Yu.; Chernobrovov, S.V.; Shul'gina, Z.I.

    1977-01-01

    Discussed are the theoretical and experimental conceptions which constitute the basis for elaboration of an electronic relay intended for automation of the exposure process during X-ray inspection of the material quality. The operating principle and circuitry of the relay are described

  6. Optimization of Thermo-Mechanical Processing for Forging of Newly Developed Creep-Resistant Magnesium Alloy ABaX633

    Directory of Open Access Journals (Sweden)

    Kamineni Pitcheswara Rao

    2017-11-01

    Full Text Available The compressive strength and creep resistance of cast Mg-6Al-3Ba-3Ca (ABaX633 alloy has been measured in the temperature range of 25 to 250 °C, and compared with that of its predecessor ABaX422. The alloy is stronger and more creep-resistant than ABaX422, and exhibits only a small decrease of yield stress with temperature. The higher strength of ABaX633 is attributed to a larger volume fraction of intermetallic particles (Al, Mg2Ca and Mg21Al3Ba2 in its microstructure. Hot deformation mechanisms in ABaX633 have been characterized by developing a processing map in the temperature and strain rate ranges of 300 to 500 °C and 0.0003 to 10 s−1. The processing map exhibits two workability domains in the temperature and strain rate ranges of: (1 380 to 475 °C and 0.0003 to 0.003 s−1, and (2 480–500 °C and 0.003 to 0.5 s−1. The apparent activation energy values estimated in the above two domains (204 and 216 kJ/mol are higher than that for lattice self-diffusion of Mg, which is attributed to the large back-stress that is caused by the intermetallic particles. Optimum condition for bulk working is 500 °C and 0.01 s−1 at which hot workability will be maximum. Flow instability is exhibited at lower temperatures and higher strain rates, as well as at higher temperatures and higher strain rates. The predictions of the processing map on the workability domains, as well as the instability regimes are fully validated by the forging of a rib-web (cup shaped component under optimized conditions.

  7. CuO nanoparticles and their antimicrobial activity against nosocomial strains

    Directory of Open Access Journals (Sweden)

    Mónica Marcela Gómez León

    2017-09-01

    Full Text Available Using a prototype reactor, CuO nanoparticles (NPs were synthetized through the precipitation method, starting from CuSO2·5H2O and Cu(CH3COO2·H2O. The obtained NPs were characterized by XDR, FT-IR, SEM, and TEM. The antimicrobial activity of the NPs was determined by the plate diffusion method, placing 20 mg of NPs onto four nosocomial strains obtained from north Lima national hospital Intensive-Care Unit (Staphylococcus epidermidis, Aerococcus viridans, Ochrobactrum anthropic, and Micrococcus lylae. NPs characterization revealed that those synthetized from acetate (CuO–Acet shown pure CuO phase, while those synthetized from sulphate CuO–Sulf shown two phases where CuO was the predominant one, having more than 84%. The crystal domains for CuO–Acet and CuO–Sulf were 15 and 19 nm, respectively. The inhibition halos for the studied strains were larger for CuO–Sulf NPs than CuO–Acet NPs, only Ochrobactrum anthropi displayed similar inhibition halos for both types of NPs.

  8. X-ray microtomography study of the compaction process of rods under tapping.

    Science.gov (United States)

    Fu, Yang; Xi, Yan; Cao, Yixin; Wang, Yujie

    2012-05-01

    We present an x-ray microtomography study of the compaction process of cylindrical rods under tapping. The process is monitored by measuring the evolution of the orientational order parameter, local, and overall packing densities as a function of the tapping number for different tapping intensities. The slow relaxation dynamics of the orientational order parameter can be well fitted with a stretched-exponential law with stretching exponents ranging from 0.9 to 1.6. The corresponding relaxation time versus tapping intensity follows an Arrhenius behavior which is reminiscent of the slow dynamics in thermal glassy systems. We also investigated the boundary effect on the ordering process and found that boundary rods order faster than interior ones. In searching for the underlying mechanism of the slow dynamics, we estimated the initial random velocities of the rods under tapping and found that the ordering process is compatible with a diffusion mechanism. The average coordination number as a function of the tapping number at different tapping intensities has also been measured, which spans a range from 6 to 8.

  9. Effect of defect on the nonlinear and dielectric property of Ca{sub (1–x)}Sr{sub x}Cu{sub 3}Ti{sub 4}O{sub 12} ceramics synthesized by sol–gel process

    Energy Technology Data Exchange (ETDEWEB)

    Li, Tao; Liu, Dewei; Dai, Haiyang; Xiang, Huiwen [Department of Technology and Physics, Zhengzhou University of Light Industry, Zhengzhou 450002 (China); Chen, Zhenping, E-mail: chaodaotai@126.com [Department of Technology and Physics, Zhengzhou University of Light Industry, Zhengzhou 450002 (China); He, Huifang; Chen, Zhiquan [Department of Physics, Hubei Nuclear Solid Physics Key Laboratory, Wuhan University, Wuhan 430072 (China)

    2014-06-25

    Highlights: • Ca{sub (1−x)}Sr{sub x}Cu{sub 3}Ti{sub 4}O{sub 12} ceramics are synthesized by sol–gel process. • Positron annihilation lifetime spectra is used to investigate the defects of samples. • Nonlinear and dielectric properties are controlled by density and defects of samples. - Abstract: Ca{sub (1−x)}Sr{sub x}Cu{sub 3}Ti{sub 4}O{sub 12} (x = 0, 0.05, 0.1, 0.15, 0.2, 0.3 and 0.4) ceramics are synthesized by sol–gel process. The XRD patterns show that weak peaks of Sr{sub 4}Ti{sub 3}O{sub 10}, TiO{sub 2} and Ca{sub 1.7}Sr{sub 0.3}CuO{sub 3} begin to appear at x ⩾ 0.2. Sr-doping is conductive to increase the density and reduce the defect concentration Ca{sub (1−x)}Sr{sub x}Cu{sub 3}Ti{sub 4}O{sub 12} ceramics as x ⩽ 0.15. With increasing x (0.2 ⩽ x ⩽ 0.4), Sr-doping reduces the density and enhances the concentration of defects for the ceramics. The nonlinear coefficient value increases and reaches a maximum 13.5 at x = 0.15, and then decreases gradually with increasing x. The dielectric properties demonstrate that, as x ⩽ 0.15, Sr-doping not only increases the dielectric permittivity value and decreases the dielectric loss but also reduces the dependence on frequency at low frequencies. With increasing x (0.2 ⩽ x ⩽ 0.4), Sr-doping begins to lead to an inverse result in dielectric behaviors. The nonlinear and dielectric properties of Ca{sub (1−x)}Sr{sub x}Cu{sub 3}Ti{sub 4}O{sub 12} ceramics are directly controlled by the density and defects.

  10. X-Ray Detection and Processing Models for Spacecraft Navigation and Timing

    Science.gov (United States)

    Sheikh, Suneel; Hanson, John

    2013-01-01

    The current primary method of deepspace navigation is the NASA Deep Space Network (DSN). High-performance navigation is achieved using Delta Differential One-Way Range techniques that utilize simultaneous observations from multiple DSN sites, and incorporate observations of quasars near the line-of-sight to a spacecraft in order to improve the range and angle measurement accuracies. Over the past four decades, x-ray astronomers have identified a number of xray pulsars with pulsed emissions having stabilities comparable to atomic clocks. The x-ray pulsar-based navigation and time determination (XNAV) system uses phase measurements from these sources to establish autonomously the position of the detector, and thus the spacecraft, relative to a known reference frame, much as the Global Positioning System (GPS) uses phase measurements from radio signals from several satellites to establish the position of the user relative to an Earth-centered fixed frame of reference. While a GPS receiver uses an antenna to detect the radio signals, XNAV uses a detector array to capture the individual xray photons from the x-ray pulsars. The navigation solution relies on detailed xray source models, signal processing, navigation and timing algorithms, and analytical tools that form the basis of an autonomous XNAV system. Through previous XNAV development efforts, some techniques have been established to utilize a pulsar pulse time-of-arrival (TOA) measurement to correct a position estimate. One well-studied approach, based upon Kalman filter methods, optimally adjusts a dynamic orbit propagation solution based upon the offset in measured and predicted pulse TOA. In this delta position estimator scheme, previously estimated values of spacecraft position and velocity are utilized from an onboard orbit propagator. Using these estimated values, the detected arrival times at the spacecraft of pulses from a pulsar are compared to the predicted arrival times defined by the pulsar s pulse

  11. Architectural Processes and Physicochemical Properties of CoO/ZnO and Zn 1− x Co x O/Co 1− y Zn y O Nanocomposites

    KAUST Repository

    Yao, Ke Xin

    2009-01-29

    In this work we synthesized two inverse kinds of cobalt and zinc oxide nanocomposites (CoO/ZnO and Zn1-xCoxO/Co 1-yZnyO) and compared methodologistic features observed from the syntheses. The binary oxide system chosen herein is because divalent cobalt and zinc have very similar ion radii, and they interdiffuse easily when forming doped structures. A "two-pot" process was devised for the CoO/ZnO composites, in which mesocrystalline cores of CoO were formed first, followed by introduction of an overlayer of ZnO nanoparticles to the core surfaces. In contrast, a "one-pot" process was developed for the Zn1-xCoxO/Co1-yZnyO composites. In particular, hollow and/or multishelled Zn1-xCoxO cores (in wurtzite phase) serve as a support for the nanospheres of Co 1-yZnyO (in rock-salt phase) in this latter method. Our findings indicate that while "multi-pot" synthesis is a prevailing methodology for composite nanoparticles, simpler "one-pot" synthesis can be an effective approach for preparation of more complex nanocomposite materials, especially for interdoped metal oxides. As an example, our as-prepared binary oxide composites Zn1-xCoxO/Co 1-yZnyO have shown good catalytic activity for oxidation of carbon monoxide at relatively low reaction temperatures. © 2009 American Chemical Society.

  12. Computer-Controlled Cylindrical Polishing Process for Large X-Ray Mirror Mandrels

    Science.gov (United States)

    Khan, Gufran S.; Gubarev, Mikhail; Speegle, Chet; Ramsey, Brian

    2010-01-01

    We are developing high-energy grazing incidence shell optics for hard-x-ray telescopes. The resolution of a mirror shells depends on the quality of cylindrical mandrel from which they are being replicated. Mid-spatial-frequency axial figure error is a dominant contributor in the error budget of the mandrel. This paper presents our efforts to develop a deterministic cylindrical polishing process in order to keep the mid-spatial-frequency axial figure errors to a minimum. Simulation software is developed to model the residual surface figure errors of a mandrel due to the polishing process parameters and the tools used, as well as to compute the optical performance of the optics. The study carried out using the developed software was focused on establishing a relationship between the polishing process parameters and the mid-spatial-frequency error generation. The process parameters modeled are the speeds of the lap and the mandrel, the tool s influence function, the contour path (dwell) of the tools, their shape and the distribution of the tools on the polishing lap. Using the inputs from the mathematical model, a mandrel having conical approximated Wolter-1 geometry, has been polished on a newly developed computer-controlled cylindrical polishing machine. The preliminary results of a series of polishing experiments demonstrate a qualitative agreement with the developed model. We report our first experimental results and discuss plans for further improvements in the polishing process. The ability to simulate the polishing process is critical to optimize the polishing process, improve the mandrel quality and significantly reduce the cost of mandrel production

  13. Process of the x-ray image formation, (2). The limit to recognize a simple figure, (2)

    Energy Technology Data Exchange (ETDEWEB)

    Mitsuta, H [Osaka City Univ. (Japan). Hospital

    1980-03-01

    In recent year, X-ray photographs can be obtained by very low dose with high sensitivity photographic system. Such very low dose makes the image quality inferior because of the fluctuation of X-ray quanta so called ''quantum noise''. The process of the X-ray image formation was evaluated from a point of view that the X-ray images are formed by the accumulation of X-ray quanta distributed randomly. And the condition that the image of a simple-shaped small object can be recognized into background quanta was investigated. Under the assumption that the quanta absorbed by an object are N sub(s) and that the average number of background quanta per area which is in the same projected area of the object is N sub(b), the condition that N sub(s) is recognizable in background is mathematically led to the following formula: N sub(s) > 4(..sqrt..N sub(b) + 1). Then the validity of this formula was experimentally shown using a computer and a simulation system by a gamma camera.

  14. The evaluation of X-ray fluorescence (XRF) for process monitoring of slag from the plasma hearth process

    International Nuclear Information System (INIS)

    Carney, K.P.; Smith, M.A.; Crane, P.J.

    1995-01-01

    Slag material produced by the Plasma Hearth Process (PHP) varies in chemical composition due to the heterogeneous nature of the input sample feed. X-ray fluorescence (XRF) is a spectroscopic technique which has been evaluated to perform elemental analyses on surrogate slag material for process control. The intensity of Si, Al and Fe in the slag samples was utilized to determine the appropriate matrix standard set for the determination of Ce. The precision of the XRF technique was better than 5% RSD. The limit of detection for Ce varied with sample matrix and was typically below 0.01 % by weight. The linear dynamic range for the technique was evaluated over 2 orders of magnitude. The Ce determinations performed directly on slag material by the XRF technique were similar to ICP-AES analyses. No addition waste streams were created from the analyses by the XRF technique

  15. The Mapping X-ray Fluorescence Spectrometer (MapX)

    Science.gov (United States)

    Sarrazin, P.; Blake, D. F.; Marchis, F.; Bristow, T.; Thompson, K.

    2017-12-01

    Many planetary surface processes leave traces of their actions as features in the size range 10s to 100s of microns. The Mapping X-ray Fluorescence Spectrometer (MapX) will provide elemental imaging at 100 micron spatial resolution, yielding elemental chemistry at a scale where many relict physical, chemical, or biological features can be imaged and interpreted in ancient rocks on planetary bodies and planetesimals. MapX is an arm-based instrument positioned on a rock or regolith with touch sensors. During an analysis, an X-ray source (tube or radioisotope) bombards the sample with X-rays or alpha-particles / gamma-rays, resulting in sample X-ray Fluorescence (XRF). X-rays emitted in the direction of an X-ray sensitive CCD imager pass through a 1:1 focusing lens (X-ray micro-pore Optic (MPO)) that projects a spatially resolved image of the X-rays onto the CCD. The CCD is operated in single photon counting mode so that the energies and positions of individual X-ray photons are recorded. In a single analysis, several thousand frames are both stored and processed in real-time. Higher level data products include single-element maps with a lateral spatial resolution of 100 microns and quantitative XRF spectra from ground- or instrument- selected Regions of Interest (ROI). XRF spectra from ROI are compared with known rock and mineral compositions to extrapolate the data to rock types and putative mineralogies. When applied to airless bodies and implemented with an appropriate radioisotope source for alpha-particle excitation, MapX will be able to analyze biogenic elements C, N, O, P, S, in addition to the cations of the rock-forming elements >Na, accessible with either X-ray or gamma-ray excitation. The MapX concept has been demonstrated with a series of lab-based prototypes and is currently under refinement and TRL maturation.

  16. Development of data acquisition and processing software based on MS-Windows 3.X for safeguards

    International Nuclear Information System (INIS)

    Tan Yajun

    1996-01-01

    The development method of data acquisition and processing software based on MS-Windows 3.X for safeguards is presented. The paper describes the design methods of graphical user interface (GUI), multiwindow and multitask-based spectrum graph display, data acquisition and processing and the application of object-oriented programming (OOP). Using the package, an effective prototype design path can be found for MS-Windows-based software. The methods and programs have been applied in some safeguard non-destructive assay system

  17. Generation X, intergenerational justice and the renewal of the traditioning process

    Directory of Open Access Journals (Sweden)

    Cory L. Seibel

    2010-10-01

    Full Text Available The church has the task of transmitting its faith tradition from one generation to the next. In the transition to postmodernity, many established congregations have proven to be ineffective at this traditioning process in relation to Generation X (Gen X, the first postmodern generation. The reasons for the ineffectiveness are complex. This article focuses on two key factors that contribute to the problem: the reduction of the church’s tradition to its particular expression within the culture of modernity and the marginalisation experienced by Gen Xers within many established churches. The latter has prevented them from becoming effective bearers of the church’s tradition. If this trend is to be reversed, churches should succeed in renewing their traditions in a way that is meaningful in a postmodern context. The challenge will be to overcome the dynamics of reductionism and marginalisation. In developing the argument, the jubilee themes of ‘return’ and ‘release’ are applied to the intergenerational dynamics of established congregations. The article concludes that local congregations should embrace a renewed commitment to intergenerational justice, which will encourage equity between the generations.

  18. X-ray imager using solution processed organic transistor arrays and bulk heterojunction photodiodes on thin, flexible plastic substrate

    NARCIS (Netherlands)

    Gelinck, G.H.; Kumar, A.; Moet, D.; Steen, J.L. van der; Shafique, U.; Malinowski, P.E.; Myny, K.; Rand, B.P.; Simon, M.; Rütten, W.; Douglas, A.; Jorritsma, J.; Heremans, P.L.; Andriessen, H.A.J.M.

    2013-01-01

    We describe the fabrication and characterization of large-area active-matrix X-ray/photodetector array of high quality using organic photodiodes and organic transistors. All layers with the exception of the electrodes are solution processed. Because it is processed on a very thin plastic substrate

  19. Germinação de sementes e desenvolvimento inicial de Erythrina mulungu (Mart. ex. Benth

    Directory of Open Access Journals (Sweden)

    Elenice de Cassia Conforto

    2014-02-01

    Full Text Available Objetivou-se escolher os melhores tratamentos pré-germinativos para as sementes e tamanhos de recipiente para o desenvolvimento inicial de plantas de Erythrina mulungu (Mart. ex. Benth. Dentre os tratamentos aplicados, a escarificação com ácido sulfúrico por 10 minutos e o corte com estilete na região oposta ao hilo resultaram, respectivamente, nos maiores resultados de porcentagem de germinação (82,8% e 82,1% e índices de velocidade de germinação (1,15 e 1,71. Não foram observados efeitos do tamanho do recipiente sobre a área foliar e a produção de massa seca das plantas. Aos 63 dias após a semeadura, embora com índice de qualidade de Dickson estatisticamente similares (média de 0,26, somente as plantas cultivadas nos recipientes pequenos e grandes atingiram o diâmetro de coleto próximo de 5 mm, valor mínimo recomendado para o plantio em campo. Assim, para o desenvolvimento inicial desta espécie, recomenda-se o pré-tratamento das sementes com ácido sulfúrico comercial, semeadura em sacos plásticos para mudas de 17 x 20 cm, e aguardo de 63 dias até o plantio em campo.

  20. Characterization of filters and filtration process using X-ray computerized tomography

    International Nuclear Information System (INIS)

    Maschio, Celio; Arruda, Antonio Celso Fonseca de

    1999-01-01

    The objective of this work is to present the potential of X-Ray computerized tomography as a tool for internal characterization of filters used in the solid-liquid separation, mainly the water filters. Cartridge filters (for industrial and domestic applications) contaminated with glass beads were used. The scanning process was carried out both with and without contaminant in the filter to compare the attenuation coefficient of the clean filter and the contaminated filter. The images showed that is possible the mapping the internal structure of the filters and the distribution of the contaminant, permitting a local analysis, that is not possible through the standard tests used by the manufactures. These standard tests reveal only global characteristics of the filter media. The possibility of application for manufacturing process control was also shown, because the non invasive nature is a important advantage of the technique, which also permitted damage detection in filters submitted to severe operational conditions. (author)

  1. Radiation-induced defects and their recombination processes in the x-ray storage phosphor BaBr2:Eu2+

    International Nuclear Information System (INIS)

    Secu, M; Schweizer, S; Rogulis, U; Spaeth, J-M

    2003-01-01

    The recombination processes in the x-ray storage phosphor BaBr 2 :Eu 2+ were investigated by optical and magneto-optical methods. A structure-sensitive investigation of the defects involved in the recombination processes was performed by detecting the microwave-induced changes in the recombination luminescence in a high magnetic field. F centres as well as V K hole centres are created after x-irradiation at low temperatures. The low-energy recombination band peaking at about 460 nm is due to F-V K centre recombinations, whereas the two high energy bands at 282 and 315 nm are probably due to recombinations of self-trapped excitons

  2. Comparison of various filtering methods for digital X-ray image processing

    International Nuclear Information System (INIS)

    Pfluger, T.; Reinfelder, H.E.; Dorschky, K.; Oppelt, A.; Siemens A.G., Erlangen

    1987-01-01

    Three filtering methods are explained and compared that are used for border edge enhancement of digitally processed X-ray images. The filters are compared by two examples, a radiograph of the chest, and one of the knee joint. The unsharpness mask is found to yield the best compromise between edge enhancement and image noise intensifying effect, whereas the results obtained by the high-pass filter or the Wallis filter are less good for diagnostic evaluation. The filtered images better display narrow lines, structural borders and edges, and finely spotted areas, than the original radiograph, so that diagnostic evaluation is easier after image filtering. (orig.) [de

  3. Thermally and optically stimulated luminescence correlated processes in X-ray irradiated KCl:Eu2+

    International Nuclear Information System (INIS)

    Chernov, V.; Melendrez Ao, R.; Piters, T.M.; Barboza-Flores, M.

    2001-01-01

    The effect of optical bleaching on thermoluminescence (TL) and thermal bleaching on optically stimulated luminescence (OSL) outputs in X-ray irradiated KCl : Eu 2+ have been investigated. The X-ray induced glow curves reveal three main peaks located at 370, 410 and 470 K. Illumination with 560 nm light leads to a drastic change of the TL glow curve. The 470 K peak is destroyed during bleaching. The other peaks initially increase in intensity and only after sufficiently long bleaching begin to decrease. After long-time bleaching, the TL peaks in X-ray irradiated crystals look like the TL peaks found in UV irradiated crystals. The effect of thermal bleaching on OSL is also very pronounced. The temperature dependencies show a step-by-step decrease of the OSL intensity correlated with the positions of the TL peaks. The result obtained shows that centers responsible for the TL peaks participate in OSL, but this participation seems not to be direct and is complicated by processes accompanying the F center bleaching

  4. Processing and quantification of x-ray energy dispersive spectra in the Analytical Electron Microscope

    International Nuclear Information System (INIS)

    Zaluzec, N.J.

    1988-08-01

    Spectral processing in x-ray energy dispersive spectroscopy deals with the extraction of characteristic signals from experimental data. In this text, the four basic procedures for this methodology are reviewed and their limitations outlined. Quantification, on the other hand, deals with the interpretation of the information obtained from spectral processing. Here the limitations are for the most part instrumental in nature. The prospects of higher voltage operation does not, in theory, present any new problems and may in fact prove to be more desirable assuming that electron damage effects do not preclude analysis. 28 refs., 6 figs

  5. Automated jitter correction for IR image processing to assess the quality of W7-X high heat flux components

    International Nuclear Information System (INIS)

    Greuner, H; De Marne, P; Herrmann, A; Boeswirth, B; Schindler, T; Smirnow, M

    2009-01-01

    An automated IR image processing method was developed to evaluate the surface temperature distribution of cyclically loaded high heat flux (HHF) plasma facing components. IPP Garching will perform the HHF testing of a high percentage of the series production of the WENDELSTEIN 7-X (W7-X) divertor targets to minimize the number of undiscovered uncertainties in the finally installed components. The HHF tests will be performed as quality assurance (QA) complementary to the non-destructive examination (NDE) methods used during the manufacturing. The IR analysis of an HHF-loaded component detects growing debonding of the plasma facing material, made of carbon fibre composite (CFC), after a few thermal cycles. In the case of the prototype testing, the IR data was processed manually. However, a QA method requires a reliable, reproducible and efficient automated procedure. Using the example of the HHF testing of W7-X pre-series target elements, the paper describes the developed automated IR image processing method. The algorithm is based on an iterative two-step correlation analysis with an individually defined reference pattern for the determination of the jitter.

  6. System for calibration of instruments of x-ray measurement (CIR-X) applying the PGCS; Sistema para calibracion de instrumentos de medicion de rayos X (CIR-X) aplicando el PGCS

    Energy Technology Data Exchange (ETDEWEB)

    Gaytan G, E.; Rivero G, T.; Cruz E, P.; Tovar M, V.M.; Vergara M, F.J. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico)]. e-mail: egg@nuclear.inin.mx

    2007-07-01

    The Department of Metrology of Ionizing Radiations of the ININ carries out calibration of instruments for X-ray measurement that determine the operation parameters in X-ray diagnostic machines of the health and private sectors. To facilitate this task, the Department of Automation and Instrumentation developed a system for acquisition and signals processing coming from a reference voltage divider with traceability at NIST that is connected directly to the X-rays tube. The system is integrated by the X-ray unit, the X-ray measurement equipment Dynalizer IIIU of RADCAL, a data acquisition card, a personal computer and the acquisition software and signals processing. (Author)

  7. Problems and image processing in X-ray film digitization

    International Nuclear Information System (INIS)

    Kato, Syousuke; Yoshita, Hisashi; Kuranishi, Makoto; Itoh, Hajime; Mori, Kouichi; Konishi, Minoru

    1992-01-01

    Aiming at the realization of PACS, a study was conducted on the present state of, and various problems associated with, X-ray film digitization using a He-Ne laser-type film digitizer. Image quality was evaluated physically and clinically. With regard to the gradation specificity, the linear specificity was shown in a dynamic range of 4 figures. With regard to resolution specificity, visual evaluation was performed using a Hawlet Chart, with almost no difference being found between the CRT and laser printer output images and the decrease in resolution becoming more pronounced as the sampling pitch became greater. Clinical evaluation was performed with reference to the literature. The general evaluation of the clinicians was that although there was some deterioration for all of the shadows, (I have read this many times, but could not understand the last part.) by performing each of the kinds of image-processing enhancement of diagnostic ability was achieved, with a diagnosis being possible. The problem of unhindered diagnosis due to the development of artifacts from optical interference of the grid images projected onto the clinical pictures and digitizer sampling pitch was studied. As countermeasures, the use of a high density grid and adoption of a low-pass filter were useful in impending the development of artifacts. Regarding the operating problems, the inputting of index information requires a considerable number of manhours and a method of automatic recognition from digital data was introduced to overcome this problem. As future-prospects, the concepts of a practical system of X-ray film digitization and a film-screen system adapted to digitization were described. (author)

  8. Problems and image processing in X-ray film digitization

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Syousuke; Yoshita, Hisashi; Kuranishi, Makoto; Itoh, Hajime; Mori, Kouichi; Konishi, Minoru (Toyama Medical and Pharmaceutical Univ. (Japan). Hospital)

    1992-11-01

    Aiming at the realization of PACS, a study was conducted on the present state of, and various problems associated with, X-ray film digitization using a He-Ne laser-type film digitizer. Image quality was evaluated physically and clinically. With regard to the gradation specificity, the linear specificity was shown in a dynamic range of 4 figures. With regard to resolution specificity, visual evaluation was performed using a Hawlet Chart, with almost no difference being found between the CRT and laser printer output images and the decrease in resolution becoming more pronounced as the sampling pitch became greater. Clinical evaluation was performed with reference to the literature. The general evaluation of the clinicians was that although there was some deterioration for all of the shadows, (I have read this many times, but could not understand the last part.) by performing each of the kinds of image-processing enhancement of diagnostic ability was achieved, with a diagnosis being possible. The problem of unhindered diagnosis due to the development of artifacts from optical interference of the grid images projected onto the clinical pictures and digitizer sampling pitch was studied. As countermeasures, the use of a high density grid and adoption of a low-pass filter were useful in impending the development of artifacts. Regarding the operating problems, the inputting of index information requires a considerable number of manhours and a method of automatic recognition from digital data was introduced to overcome this problem. As future-prospects, the concepts of a practical system of X-ray film digitization and a film-screen system adapted to digitization were described. (author).

  9. Complex of structural roentgenometric and optical parameters of chest X-ray picture for automated fluorograms processing

    International Nuclear Information System (INIS)

    Rodzaevskij, S.A.

    1986-01-01

    The formalized description necessary for the development of algorithms for determination of main object boundaries by the roentgenologic picture during computerized photoroentgenograms processing is drawn up on the basis of the complex of structural roentgenometric parameters of the chest X-ray picture

  10. A method for visual inspection of welding by means of image processing of x-ray photograph

    International Nuclear Information System (INIS)

    Koshimizu, Hiroyasu; Yoshida, Tohru.

    1983-01-01

    Computer image processing is becoming a helpful tool even in industrial inspections. A computerized method for welding visual inspection is proposed in this paper. This method is based on computer image processing of X-ray photograph of welding, in which the appearance information of weldments such as shape of weld bead really exists. Structural patterns are extracted at first and seven computer measures for inspection are calculated using those patterns. Software system for visual inspection is constructed based on these seven measures. It was experimentally made clear that this system can provide a performance of more than 0.85 correlation to human visual inspection. As a result, the visual inspection by computer using X-ray photograph became a promising tool to realize objectivity and quantitativity of welding inspection. Additionally, the consistency of the system, the possibility to reduce computing costs, and so on are discussed to improve the proposed method. (author)

  11. Improvement of multi-level resistive switching characteristics in solution-processed AlO x -based non-volatile resistive memory using microwave irradiation

    Science.gov (United States)

    Kim, Seung-Tae; Cho, Won-Ju

    2018-01-01

    We fabricated a resistive random access memory (ReRAM) device on a Ti/AlO x /Pt structure with solution-processed AlO x switching layer using microwave irradiation (MWI), and demonstrated multi-level cell (MLC) operation. To investigate the effect of MWI power on the MLC characteristics, post-deposition annealing was performed at 600-3000 W after AlO x switching layer deposition, and the MLC operation was compared with as-deposited (as-dep) and conventional thermally annealing (CTA) treated devices. All solution-processed AlO x -based ReRAM devices exhibited bipolar resistive switching (BRS) behavior. We found that these devices have four-resistance states (2 bits) of MLC operation according to the modulation of the high-resistance state (HRSs) through reset voltage control. Particularly, compared to the as-dep and CTA ReRAM devices, the MWI-treated ReRAM devices showed a significant increase in the memory window and stable endurance for multi-level operation. Moreover, as the MWI power increased, excellent MLC characteristics were exhibited because the resistance ratio between each resistance state was increased. In addition, it exhibited reliable retention characteristics without deterioration at 25 °C and 85 °C for 10 000 s. Finally, the relationship between the chemical characteristics of the solution-processed AlO x switching layer and BRS-based multi-level operation according to the annealing method and MWI power was investigated using x-ray photoelectron spectroscopy.

  12. Enhanced Excitatory Connectivity and Disturbed Sound Processing in the Auditory Brainstem of Fragile X Mice.

    Science.gov (United States)

    Garcia-Pino, Elisabet; Gessele, Nikodemus; Koch, Ursula

    2017-08-02

    Hypersensitivity to sounds is one of the prevalent symptoms in individuals with Fragile X syndrome (FXS). It manifests behaviorally early during development and is often used as a landmark for treatment efficacy. However, the physiological mechanisms and circuit-level alterations underlying this aberrant behavior remain poorly understood. Using the mouse model of FXS ( Fmr1 KO ), we demonstrate that functional maturation of auditory brainstem synapses is impaired in FXS. Fmr1 KO mice showed a greatly enhanced excitatory synaptic input strength in neurons of the lateral superior olive (LSO), a prominent auditory brainstem nucleus, which integrates ipsilateral excitation and contralateral inhibition to compute interaural level differences. Conversely, the glycinergic, inhibitory input properties remained unaffected. The enhanced excitation was the result of an increased number of cochlear nucleus fibers converging onto one LSO neuron, without changing individual synapse properties. Concomitantly, immunolabeling of excitatory ending markers revealed an increase in the immunolabeled area, supporting abnormally elevated excitatory input numbers. Intrinsic firing properties were only slightly enhanced. In line with the disturbed development of LSO circuitry, auditory processing was also affected in adult Fmr1 KO mice as shown with single-unit recordings of LSO neurons. These processing deficits manifested as an increase in firing rate, a broadening of the frequency response area, and a shift in the interaural level difference function of LSO neurons. Our results suggest that this aberrant synaptic development of auditory brainstem circuits might be a major underlying cause of the auditory processing deficits in FXS. SIGNIFICANCE STATEMENT Fragile X Syndrome (FXS) is the most common inheritable form of intellectual impairment, including autism. A core symptom of FXS is extreme sensitivity to loud sounds. This is one reason why individuals with FXS tend to avoid social

  13. X-ray metrology for ULSI structures

    International Nuclear Information System (INIS)

    Bowen, D. K.; Matney, K. M.; Wormington, M.

    1998-01-01

    Non-destructive X-ray metrological methods are discussed for application to both process development and process control of ULSI structures. X-ray methods can (a) detect the unacceptable levels of internal defects generated by RTA processes in large wafers, (b) accurately measure the thickness and roughness of layers between 1 and 1000 nm thick and (c) can monitor parameters such as crystallographic texture and the roughness of buried interfaces. In this paper we review transmission X-ray topography, thin film texture measurement, grazing-incidence X-ray reflectivity and high-resolution X-ray diffraction. We discuss in particular their suitability as on-line sensors for process control

  14. Antimony assisted low-temperature processing of CuIn1-xGaxSe2-ySy solar cells

    International Nuclear Information System (INIS)

    Yuan Min; Mitzi, David B.; Gunawan, Oki; Kellock, Andrew J.; Chey, S. Jay; Deline, Vaughn R.

    2010-01-01

    Application of the Sb-doping method to low-temperature (≤ 400 o C) processing of CuIn 1-x Ga x Se 2-y S y (CIGS) solar cells is explored, using a hydrazine-based approach to deposit the absorber films. Power conversion efficiencies of 10.5% and 8.4% have been achieved for CIGS devices (0.45 cm 2 device area) processed at 400 o C and 360 o C, respectively, with an Sb-incorporation level at 1.2 mol % (relative to the moles of CIGS). Significant Sb-induced grain size enhancement was confirmed for these low processing temperatures using cross-sectional scanning electron microscopy, and an average 2-3% absolute efficiency improvement was achieved in Sb-doped samples compared to their Sb-free sister samples. With Sb inclusion, the CIGS film grain growth temperature is lowered to well below 450 o C, a range compatible with flexible polymer substrate materials such as polyimide. This method opens up access to opportunities in low-temperature processing of CIGS solar cells, an area that is being actively pursued using both traditional vacuum-based as well as other solution-based deposition techniques.

  15. Bayesian Maximum Entropy Based Algorithm for Digital X-ray Mammogram Processing

    Directory of Open Access Journals (Sweden)

    Radu Mutihac

    2009-06-01

    Full Text Available Basics of Bayesian statistics in inverse problems using the maximum entropy principle are summarized in connection with the restoration of positive, additive images from various types of data like X-ray digital mammograms. An efficient iterative algorithm for image restoration from large data sets based on the conjugate gradient method and Lagrange multipliers in nonlinear optimization of a specific potential function was developed. The point spread function of the imaging system was determined by numerical simulations of inhomogeneous breast-like tissue with microcalcification inclusions of various opacities. The processed digital and digitized mammograms resulted superior in comparison with their raw counterparts in terms of contrast, resolution, noise, and visibility of details.

  16. Characterisation of corrosion processes of using electron micro-probe, scanning probe microscopy and synchrotron-generated x-ray fluorescence imaging

    International Nuclear Information System (INIS)

    Neufeld, A.K.; Cole, I.S.; Furman, S.A.; Isaacs, H.S.

    2002-01-01

    Full text: With recent advances in computerized technology, the study of chemical reactions can now be visualized as they occur in real time and has resulted in analytical techniques with orders of magnitude greater sensitivity and resolution. This ability offers the corrosion scientist a unique opportunity to study the processes relevant to degradation science which could only be theoretically considered. Neufeld el al (1,2) have attempted to explain in great detail the mechanism of corrosion initiation of zinc by using X-ray micro-probe, Scanning Kelvin probe, and more recently by using synchrotron-generated X-rays and X-ray fluorescence imaging. New results are presented from the synchrotron studies where the transport of ions in-situ has been investigated. The synthesis of information from the techniques will also be discussed in its relevance to atmospheric corrosion processes. Copyright (2002) Australian Society for Electron Microscopy Inc

  17. Design and fabrication process of silicon micro-calorimeters on simple SOI technology for X-ray spectral imaging

    International Nuclear Information System (INIS)

    Aliane, A.; Agnese, P.; Pigot, C.; Sauvageot, J.-L.; Moro, F. de; Ribot, H.; Gasse, A.; Szeflinski, V.; Gobil, Y.

    2008-01-01

    Several successful development programs have been conducted on infra-red bolometer arrays at the 'Commissariat a l'Energie Atomique' (CEA-LETI Grenoble) in collaboration with the CEA-SAp (Saclay); taking advantage of this background, we are now developing an X-ray spectro-imaging camera for next generation space astronomy missions, using silicon only technology. We have developed monolithic silicon micro-calorimeters based on implanted thermistors in an improved array that could be used for future space missions. The 8x8 array consists of a grid of 64 suspended pixels fabricated on a silicon on insulator (SOI) wafer. Each pixel of this detector array is made of a tantalum (Ta) absorber, which is bound by means of indium bump hybridization, to a silicon thermistor. The absorber array is bound to the thermistor array in a collective process. The fabrication process of our detector involves a combination of standard technologies and silicon bulk micro-machining techniques, based on deposition, photolithography and plasma etching steps. Finally, we present the results of measurements performed on these four primary building blocks that are required to create a detector array up to 32x32 pixels in size

  18. Thorium determination by X-ray Fluorescence Spectrometry in simulated thorex process solutions

    International Nuclear Information System (INIS)

    Yamaura, M.; Matsuda, H.T.

    1989-01-01

    The X-ray fluorescence method for thorium determination in aqueous and organic (TBP-n-dodecane) solutions is described. The thin film-technique for sample preparation and a suitable internal standard have been used. Some parameters as analytical line, internal standard, filter paper, paper geometry, sample volume and measurement conditions were studied. Uranium, fission products, corrosion products and thorex reagent components were studied as interfering elements in the thorium analysis, as well as the matrix effect by using the thorex process simulated solutions the method to thorium determination in irradiated thorium solutions was applied. (M.J.C.) [pt

  19. An X window based graphics user interface for radiation information processing system developed with object-oriented programming technology

    International Nuclear Information System (INIS)

    Gao Wenhuan; Fu Changqing; Kang Kejun

    1993-01-01

    X Window is a network-oriented and network transparent windowing system, and now dominant in the Unix domain. The object-oriented programming technology can be used to change the extensibility of a software system remarkably. An introduction to graphics user interface is given. And how to develop a graphics user interface for radiation information processing system with object-oriented programming technology, which is based on X Window and independent of application is described briefly

  20. Superconductor-insulator-normal-conductor-insulator-superconductor (Nb/Al{sub x}O{sub y}/Al/Al{sub x}O{sub y}/Nb) process development for integrated circuit applications

    Energy Technology Data Exchange (ETDEWEB)

    Balashov, D.; Buchholz, F.M.; Schulze, H.; Khabipov, M.I.; Kessel, W.; Niemeyer, J. [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany)

    1998-12-01

    The paper reports on recent developments in a new technology process in LTS implementation to fabricate intrinsically shunted tunnel junctions. The process has been realized in SINIS Nb/Al{sub x}O{sub y}/Al/Al{sub x}O{sub y}/Nb multilayer thin-film technology. In various test series, circuits containing a large variety of single junctions and junction arrays of different contact areas and sizes were fabricated and measured. By variation of the oxidation parameters the fabrication process has been optimized for application in integrated circuits operating in RSFQ impulse logic. The junction parameter values realized for the critical current density j{sub c} range to up to about j{sub c} = 1000 A cm{sup -2}, those for the characteristic voltage V{sub c} to up to about V{sub c} = 230 {mu}V. The junctions show nearly non-hysteretic current-voltage characteristics; the intra-wafer parameter spread is below 10%. The junctions realized fulfil the requirements imposed for digital RSFQ circuit operation at clock frequencies in the lower GHz frequency range. (author)

  1. Vacancy behavior in Cu(In{sub 1−x}Ga{sub x})Se{sub 2} layers grown by a three-stage coevaporation process probed by monoenergetic positron beams

    Energy Technology Data Exchange (ETDEWEB)

    Uedono, Akira; Islam, Muhammad M.; Sakurai, Takeaki [Division of Applied Physics, Faculty of Pure and Applied Science, University of Tsukuba, Tsukuba, Ibaraki 305-8573 (Japan); Hugenschmidt, Christoph [Physics Department E21 and Heinz Maier-Leibnitz Zentrum (MLZ), Technische Universität München, 85748 Garching (Germany); Egger, Werner [Universität der Bundeswehr München, Institut für Angewandte Physik und Messtechnik, 85577 Neubiberg (Germany); Scheer, Roland; Krause-Rehberg, Reinhard [Department of Physics, Martin Luther University Halle, 06099 Halle (Germany); Akimoto, Katsuhiro [Division of Applied Physics, Faculty of Pure and Applied Science, University of Tsukuba, Tsukuba, Ibaraki 305-8573 (Japan)

    2016-03-31

    Vacancy-type defects in Cu(In{sub 1−x}Ga{sub x})Se{sub 2} (x ≅ 0.45 and 1) grown by a three-stage coevaporation process were probed using monoenergetic positron beams. Measurements of Doppler broadening spectra of the annihilation radiation and positron lifetime spectra showed that two different defect species coexist in the Cu(In{sub 1−x}Ga{sub x})Se{sub 2} layers, and these were identified as mono/divacancy-type defects and vacancy clusters, respectively. The vacancy clusters were mainly introduced during the third growth stage, and were located in the subsurface region. The concentration of the defects affected the short-circuit current density and the conversion efficiency of the solar cells. The defect concentration and their depth distributions varied depending on Se beam equivalent pressure, growth time, and post-growth annealing time. The behavior of the vacancy-type defects is discussed also with respect to results obtained using an electron probe micro-analyzer. - Highlights: • We applied positron annihilation to characterize Cu(In{sub 1−x}Ga{sub x})Se{sub 2}. • Defect species were identified as mono/divacancy-type defects and vacancy clusters. • The conversion efficiency increased with a decreasing vacancy concentration.

  2. Microfocussing of synchrotron X-rays using X-ray refractive lens

    Indian Academy of Sciences (India)

    X-ray lenses are fabricated in polymethyl methacrylate using deep X-ray lithography beamline of Indus-2. The focussing performance of these lenses is evaluated using Indus-2 and Diamond Light Source Ltd. The process steps for the fabrication of X-ray lenses and microfocussing at 10 keV at moderate and low emittance ...

  3. Pressão interna e refração molar dos sistemas dimetilsulfóxido + tiofeno, dimetilsulfóxido + piridina a 298,15K

    OpenAIRE

    AZNAREZ, Silvia Beatriz; POSTIGO, Miguel Ángelo; MARTINS, Adair

    1999-01-01

    Pressão interna, volume livre, refração molar e propriedades termodinâmicas de excesso de misturas líquidas binárias de dimetil sulfóxido + tiofeno e dimetil sulfóxido + piridina a 298.15K foram calculadas a partir de medidas experimentais de densidades, tensão superficial e índice de refração. A relação entre a pressão interna, volume molar de excesso, refração molar, e a interação molecular dos sistemas binários é examinada. Internal pressure, free volume, molar refraction and excess mol...

  4. Processing and characterization of Sr2−xVMoO6−δ double perovskites

    International Nuclear Information System (INIS)

    Weisentein, A.J.; Childs, N.; Amendola, R.; Driscoll, D.; Sofie, S.W.; Gannon, P.; Smith, R.

    2013-01-01

    In this study, the analysis and characterization of the processing and sintering of Sr 2−x VMoO 6−δ perovskites, where x = 0.0, 0.1 and 0.2, was investigated with application potential in high temperature fuel cell electrodes and electro-catalysts. Sr 2−x VMoO 6−δ substrates were sintered in a reducing (5%H 2 95%N 2 ) atmosphere at 1100 °C, 1200 °C, and 1300 °C. The X-ray diffraction patterns indicate that the double perovskite is the primary phase for Sr 2−x VMoO 6−δ pellets sintered at 1200 °C and 1300 °C for 20 h; however, these pellets show a secondary phase of SrMoO 4−δ . X-ray photoelectron spectroscopy revealed a deficiency of vanadium on the pellet surfaces, in which samples yielded surface vanadium concentrations of less than 5%. The vanadium inhomogeneity can be explained by the formation of the SrMoO 4−δ scheelite phase (ABO 4 ) due to oxygen exposure on the surface of the pellets, which indicates inward vanadium migration to the bulk, and was exhibited in redox cycling. Sr 2−x VMoO 6−δ pellets sintered at 1300 °C showed the lowest resistivity at both SOFC operating temperature (800 °C) and room temperature. The resistivity tests also show a semiconductor to metallic transition for all double perovskites, from heating up to 800 °C to cooling down to room temperature in a reducing atmosphere, related to the reduction of Mo 6+ to Mo 4+ . - Highlights: ► Primary Sr 2−x VMoO 6−δ phase only shown to form in excess of 1300 °C in reducing. ► Surface formation of secondary phase SrMoO 4−δ (Mo 6+ ) observed at RT in air. ► Surface vanadium deficiency induced by inward atomic diffusion. ► Semiconductor to metallic transition is related to the reduction of Mo 6+ to Mo 4+

  5. Uranium enrichment measurement by X- and γ-ray spectrometry with the 'URADOS' process

    International Nuclear Information System (INIS)

    Morel, Jean; Etcheverry, Michel; Riazuelo, Gilles

    1998-01-01

    The methods used for the uranium enrichment measurement require in general prior instrument calibration with several standards. Thus, it is possible to avoid the constraints involved in calibration by considering the complex spectral region called XK α . This spectral region is sufficiently limited so that the variation of the detector efficiency response is small enough to facilitate a self-calibration. Processing this region is critical and requires taking into account 3 elemental images, one corresponding to 235 U, one to 238 U and one to the X-ray fluorescence induced in the sample by radiation above 100 keV. A process called 'URADOS' based on this principle has been developed. Six uranium oxide standards with different enrichments and infinite thicknesses were counted several times to test this process; other samples, some highly enriched, were also used. The results obtained are compared to the declared values. From these measurements, it has been possible to improve the photon emission probability values

  6. The quality of X-ray film processing. Report of a sensitometric field study

    International Nuclear Information System (INIS)

    Stargardt, A.; Buehler, G.

    1985-01-01

    One hundred and eighty of about 800 X-ray film processors used in the GDR were checked sensitometrically. Sensitometric control strips, pre-exposed at a certain level, were mailed, processed and re-mailed; fog, the density of a medium-density step and a density difference were then determined. Reference data were obtained by processing exactly according to the recommendations of the film manufacturer; the mean of fog measurements equals the reference value. Seven per cent of processors produced fog which was unacceptable. The mean of the medium density measurements was 10% below the reference value. Five per cent of all processors operated at unacceptably high, and 16% at unacceptably low, density. Since failures in processing are commonly compensated for by changing radiation doses, consequences for radiation exposure are obvious. Analysis of data on operating parameters supplied by the users identified the disproportion between developer replenisher rate and film load as the main reason for this unsatisfactory situation. (author)

  7. In situ flash x-ray high-speed computed tomography for the quantitative analysis of highly dynamic processes

    Science.gov (United States)

    Moser, Stefan; Nau, Siegfried; Salk, Manfred; Thoma, Klaus

    2014-02-01

    The in situ investigation of dynamic events, ranging from car crash to ballistics, often is key to the understanding of dynamic material behavior. In many cases the important processes and interactions happen on the scale of milli- to microseconds at speeds of 1000 m s-1 or more. Often, 3D information is necessary to fully capture and analyze all relevant effects. High-speed 3D-visualization techniques are thus required for the in situ analysis. 3D-capable optical high-speed methods often are impaired by luminous effects and dust, while flash x-ray based methods usually deliver only 2D data. In this paper, a novel 3D-capable flash x-ray based method, in situ flash x-ray high-speed computed tomography is presented. The method is capable of producing 3D reconstructions of high-speed processes based on an undersampled dataset consisting of only a few (typically 3 to 6) x-ray projections. The major challenges are identified, discussed and the chosen solution outlined. The application is illustrated with an exemplary application of a 1000 m s-1 high-speed impact event on the scale of microseconds. A quantitative analysis of the in situ measurement of the material fragments with a 3D reconstruction with 1 mm voxel size is presented and the results are discussed. The results show that the HSCT method allows gaining valuable visual and quantitative mechanical information for the understanding and interpretation of high-speed events.

  8. X-ray film calibration

    International Nuclear Information System (INIS)

    Stone, G.F.; Dittmore, C.H.; Henke, B.L.

    1986-01-01

    This paper discusses the use of silver halide x-ray films for imaging and spectroscopy which is limited by the range of intensities that can be recorded and densitometered. Using the manufacturers processing techniques can result in 10 2-3 range in intensity recorded over 0-5 density range. By modifying the chemistry and processing times, ranges of 10 5-6 can be recorded in the same density range. The authors report on x-ray film calibration work and dynamic range improvements. Changes to the processing chemistry and the resulting changes in dynamic range and x-ray sensitivity are discussed

  9. Investigation of optimal manufacturing process for freeze-dried formulations: Observation of frozen solutions by low temperature X-ray diffraction measurements

    International Nuclear Information System (INIS)

    Egawa, Hiroaki; Yonemochi, Etsuo; Terada, Katsuhide

    2005-01-01

    Freeze-drying is used for the production of sterile injections in the pharmaceutical industry. However, most pharmaceutical compounds are obtained as less stable amorphous form. Freeze crystallization by annealing is an effective method for pharmaceutical compounds that fail to crystallize in the freeze-drying process. Crystallization occurs in the frozen solution during the thermal treatment. In order to establish suitable annealing conditions efficiently, it is important to observe the crystallization process directly in the frozen solution. Recently, low temperature X-ray diffraction has been used to observe frozen solutions. In order to investigate the crystallization process kinetically, the temperature of the low temperature X-ray diffraction instrument must be accurately controlled. We calibrated the temperature of X-ray diffraction instrument by measuring eutectic temperatures of solutions for a series of compounds. Each eutectic crystal was observed in frozen solution with ice crystal below the eutectic temperature. Eutectic temperatures were detected by the decrease in diffraction intensity associated with heating from below the eutectic temperature. Good correlation was obtained between values in the literature and experimental values

  10. An open software system based on X Windows for process control and equipment monitoring

    International Nuclear Information System (INIS)

    Aimar, A.; Carlier, E.; Mertens, V.

    1992-01-01

    The construction and application of a configurable open software system for process control and equipment monitoring can speed up and simplify the development and maintenance of equipment specific software as compared to individual solutions. The present paper reports the status of such an approach for the distributed control systems of SPS and LEP beam transfer components, based on X Windows and the OSF/Motif tool kit and applying data modeling and software engineering methods. (author)

  11. Accelerators for E-beam and X-ray processing

    Energy Technology Data Exchange (ETDEWEB)

    Auslender, V.L. E-mail: auslen@inp.nsk.su; Bryazgin, A.A.; Faktorovich, B.L.; Gorbunov, V.A.; Kokin, E.N.; Korobeinikov, M.V.; Krainov, G.S.; Lukin, A.N.; Maximov, S.A.; Nekhaev, V.E.; Panfilov, A.D.; Radchenko, V.N.; Tkachenko, V.O.; Tuvik, A.A.; Voronin, L.A

    2002-03-01

    During last years the demand for pasteurization and desinsection of various food products (meat, chicken, sea products, vegetables, fruits, etc.) had increased. The treatment of these products in industrial scale requires the usage of powerful electron accelerators with energy 5-10 MeV and beam power at least 50 kW or more. The report describes the ILU accelerators with energy range up to 10 MeV and beam power up to 150 kW.The different irradiation schemes in electron beam and X-ray modes for various products are described. The design of the X-ray converter and 90 deg. beam bending system are also given.

  12. Collins effect in single spin asymmetries of the p↑p →πX process

    International Nuclear Information System (INIS)

    Ma, Bo-Qiangq; Schmidt, I.; Yang Jianjun

    2005-01-01

    We investigate the Collins effect in single spin asymmetries (SSAs) of the p ↑ p →πX process by taking into account the transverse momentum dependence of the microscopic sub-process cross sections, with the transverse momentum in the Collins function integrated over. We find that the asymmetries due to the Collins effect can only explain the available data at best qualitatively, by using our choices of quark distributions in the quark-diquark model and a pQCD-based analysis, together with several options of the Collins function. Our results indicate the necessity to take into account contributions from other effects such as the Sivers effect or twist-3 contributions. (orig.)

  13. Tail gas treatment of sour-SEWGS CO2 product. Public version

    Energy Technology Data Exchange (ETDEWEB)

    Van Dijk, H.A.J. [ECN Biomass and Energy Efficiency, Petten (Netherlands)

    2012-06-15

    This literature review covers the technologies suitable for the CO2-H2S separation within the context of CO2 purification of a pre-combustion captured stream intended for storage or reuse. The technologies considered cover existing industrially applied processes, emerging processes as well as processes in development. Several technologies capable of achieving the desired CO2-H2S separation were identified. Among them are liquid scrubbing processes Thiopaq and CrystaSulf producing elemental sulphur, selective oxidation to elemental sulphur such as MODOP or based on novel catalysts and sorbent-based (reactive) separations using low-, medium- or high-temperature (reactive) sorbents. SEWGS stands for Sorption Enhanced Water Gas Shift process.

  14. Low NO sub x /SO sub x Burner retrofit for utility cyclone boilers

    Energy Technology Data Exchange (ETDEWEB)

    1991-09-01

    This Public Design Report provides available nonproprietary design information on the Low NO{sub x}SO{sub x} Burner Retrofit of Utility Cyclone Boilers project. In addition to the design aspects, the history of the project, the organization of the project, and the role of the funding parties are discussed. An overview of the Low NO{sub x}SO{sub x} (LNS) Burner, the cyclone boiler and the Southern Illinois Power Cooperative host site is presented. A detailed nonproprietary description of the individual process steps, plant systems, and resulting performance then follows. Narrative process descriptions, simplified process flow diagrams, input/output stream data, operating conditions and requirements are given for each unit. The plant demonstration program and start up provisions, the environmental considerations and control, monitoring and safety factors that are considered are also addressed.

  15. X-Ray Amorphous Phases in Antarctica Dry Valley Soils: Insight into Aqueous Alteration Processes on Mars?

    Science.gov (United States)

    Ming, D. W.; Morris, R. V.; Rampe, E. B.; Golden, D. C.; Quinn, J. E.

    2015-01-01

    may have been physically and chemical altered during soil formation, however, the limited interaction with water and low temperatures may result in the formation of "immature" X-ray amorphous or SRO materials. Perhaps, a similar process contributes to the formation of the high content of X-ray amorphous materials detected on Mars.

  16. Effects of calcium doping on the superconducting properties of top-seeded melt growth processed Y1.5Ba2-xCaxCu3Oy superconductors

    International Nuclear Information System (INIS)

    Park, S.D.; Kim, H.J.; Park, B.J.; Han, Y.H.; Jun, B.-H.; Lee, J.S.; Kim, C.-J.

    2011-01-01

    We study effects of calcium doping in melt processed Y123 superconductors. We examine a superconducting transition temperature and current density. A transition temperature and current density decreases by calcium doping. Calcium doping leads to coarseing of Y211 particles. Y211 refining effect by CeO 2 is disappreared by calcium doping. The effect of calcium doping on the superconducting properties of top seeded melt growth (TSMG) processed Y 1.5 Ba 2-x Ca x Cu 3 O y superconductors was studied in terms of calcium content (X ca ). YBa 2-x Ca x Cu 3 O 7-δ (X ca = 0, 0.005, 0.01, 0.02, 0.04, 0.1, 0.3) powders were synthesized by the powder calcination method. YBa 2-x Ca x Cu 3 O 7-δ powders were mixed with 0.25 mole Y 2 O 3 powder and 1 wt.% CeO 2 as Y 2 BaCuO 5 (Y211) refiner, and finally made into Y 1 . 5 Ba 2-x Ca x Cu 3 O y (Y1.5) + 1 wt.% CeO 2 composition. The single Y123 growth on the top surface was observed up to X ca = 0.1, while the multiple Y123 growth was observed at X ca ≥ 0.1. The superconducting transition temperature (T c ) and critical current density (J c ) of TSMG processed Y1.5 samples were inversely proportional to X ca . The Y211 size increased with increasing X ca due to the enhancement of Y211 coarsening by calcium doping. No Y211 refining effect by CeO 2 was observed in the calcium doped samples. The T c and J c decrease by calcium doping are likely to be due to the calcium incorporation with the Y123 lattice and formation of coarse Y211 particles.

  17. Monitoring alloy formation during mechanical alloying process by x-ray diffraction techniques

    International Nuclear Information System (INIS)

    Abdul Kadir Masrom; Noraizam Md Diah; Mazli Mustapha

    2002-01-01

    Monitoring alloying (MA) is a novel processing technique that use high energy impact ball mill to produce alloys with enhanced properties and microscopically homogeneous materials starting from various powder mixtures. Mechanical alloying process was originally developed to produce oxide dispersion strengthened nickel superalloys. In principal, in high-energy ball milling process, alloy is formed by the result of repeated welding, fracturing and rewelding of powder particles in a high energy ball mill. In this process a powder mixture in a ball mill is subjected to high-energy collisions among balls. MA has been shown to be capable of synthesizing a variety of materials. It is known to be capable to prepare equilibrium and non-equilibrium phases starting from blended elemental or prealloyed powders. The process ability to produce highly metastable materials such as amorphous alloys and nanostructured materials has made this process attractive and it has been considered as a promising material processing technique that could be used to produce many advanced materials at low cost. The present study explores the conditions under which aluminum alloys formation occurs by ball milling of blended aluminum and its alloying elements powders. In this work, attempt was made in producing aluminum 2024 alloys by milling of blended elemental aluminum powder of 2024 composition in a stainless steel container under argon atmosphere for up to 210 minutes. X-ray diffraction together with thermal analysis techniques has been used to monitor phase changes in the milled powder. Results indicate that, using our predetermined milling parameters, alloys were formed after 120 minutes milling. The thermal analysis data was also presented in this report. (Author)

  18. Abnormal presynaptic short-term plasticity and information processing in a mouse model of fragile X syndrome.

    Science.gov (United States)

    Deng, Pan-Yue; Sojka, David; Klyachko, Vitaly A

    2011-07-27

    Fragile X syndrome (FXS) is the most common inherited form of intellectual disability and the leading genetic cause of autism. It is associated with the lack of fragile X mental retardation protein (FMRP), a regulator of protein synthesis in axons and dendrites. Studies on FXS have extensively focused on the postsynaptic changes underlying dysfunctions in long-term plasticity. In contrast, the presynaptic mechanisms of FXS have garnered relatively little attention and are poorly understood. Activity-dependent presynaptic processes give rise to several forms of short-term plasticity (STP), which is believed to control some of essential neural functions, including information processing, working memory, and decision making. The extent of STP defects and their contributions to the pathophysiology of FXS remain essentially unknown, however. Here we report marked presynaptic abnormalities at excitatory hippocampal synapses in Fmr1 knock-out (KO) mice leading to defects in STP and information processing. Loss of FMRP led to enhanced responses to high-frequency stimulation. Fmr1 KO mice also exhibited abnormal synaptic processing of natural stimulus trains, specifically excessive enhancement during the high-frequency spike discharges associated with hippocampal place fields. Analysis of individual STP components revealed strongly increased augmentation and reduced short-term depression attributable to loss of FMRP. These changes were associated with exaggerated calcium influx in presynaptic neurons during high-frequency stimulation, enhanced synaptic vesicle recycling, and enlarged readily-releasable and reserved vesicle pools. These data suggest that loss of FMRP causes abnormal STP and information processing, which may represent a novel mechanism contributing to cognitive impairments in FXS.

  19. Strategy and model building in the fourth dimension: a null model for genotype x age interaction as a Gaussian stationary stochastic process.

    Science.gov (United States)

    Diego, Vincent P; Almasy, Laura; Dyer, Thomas D; Soler, Júlia M P; Blangero, John

    2003-12-31

    Using univariate and multivariate variance components linkage analysis methods, we studied possible genotype x age interaction in cardiovascular phenotypes related to the aging process from the Framingham Heart Study. We found evidence for genotype x age interaction for fasting glucose and systolic blood pressure. There is polygenic genotype x age interaction for fasting glucose and systolic blood pressure and quantitative trait locus x age interaction for a linkage signal for systolic blood pressure phenotypes located on chromosome 17 at 67 cM.

  20. System for calibration of instruments of x-ray measurement (CIR-X) applying the PGCS

    International Nuclear Information System (INIS)

    Gaytan G, E.; Rivero G, T.; Cruz E, P.; Tovar M, V.M.; Vergara M, F.J.

    2007-01-01

    The Department of Metrology of Ionizing Radiations of the ININ carries out calibration of instruments for X-ray measurement that determine the operation parameters in X-ray diagnostic machines of the health and private sectors. To facilitate this task, the Department of Automation and Instrumentation developed a system for acquisition and signals processing coming from a reference voltage divider with traceability at NIST that is connected directly to the X-rays tube. The system is integrated by the X-ray unit, the X-ray measurement equipment Dynalizer IIIU of RADCAL, a data acquisition card, a personal computer and the acquisition software and signals processing. (Author)

  1. The probability to initiate X chromosome inactivation is determined by the X to autosomal ratio and X chromosome specific allelic properties.

    Directory of Open Access Journals (Sweden)

    Kim Monkhorst

    Full Text Available In female mammalian cells, random X chromosome inactivation (XCI equalizes the dosage of X-encoded gene products to that in male cells. XCI is a stochastic process, in which each X chromosome has a probability to be inactivated. To obtain more insight in the factors setting up this probability, we studied the role of the X to autosome (X ratio A ratio in initiation of XCI, and have used the experimental data in a computer simulation model to study the cellular population dynamics of XCI.To obtain more insight in the role of the XratioA ratio in initiation of XCI, we generated triploid mouse ES cells by fusion of haploid round spermatids with diploid female and male ES cells. These fusion experiments resulted in only XXY triploid ES cells. XYY and XXX ES lines were absent, suggesting cell death related either to insufficient X-chromosomal gene dosage (XYY or to inheritance of an epigenetically modified X chromosome (XXX. Analysis of active (Xa and inactive (Xi X chromosomes in the obtained triploid XXY lines indicated that the initiation frequency of XCI is low, resulting in a mixed population of XaXiY and XaXaY cells, in which the XaXiY cells have a small proliferative advantage. This result, and findings on XCI in diploid and tetraploid ES cell lines with different X ratio A ratios, provides evidence that the X ratio A ratio determines the probability for a given X chromosome to be inactivated. Furthermore, we found that the kinetics of the XCI process can be simulated using a probability for an X chromosome to be inactivated that is proportional to the X ratio A ratio. These simulation studies re-emphasize our hypothesis that the probability is a function of the concentration of an X-encoded activator of XCI, and of X chromosome specific allelic properties determining the threshold for this activator.The present findings reveal that the probability for an X chromosome to be inactivated is proportional to the X ratio A ratio. This finding

  2. Lixiviación de calcopirita mecánicamente activada utilizando ácido sulfúrico

    Directory of Open Access Journals (Sweden)

    Danny Guzmán

    2010-01-01

    Full Text Available Con el objetivo de estudiar el efecto de la activación mecánica sobre la lixiviación de CuFeS2, cuatro muestras de este mineral fueron sometidas a molienda durante 1, 5, 8, y 15 h en un molino Atritor. Los polvos obtenidos fueron caracterizados microestructuralmente y morfológicamente mediante difracción de Rayos-X (DRX y microscopía electrónica de barrido (MEB, respectivamente. Posteriormente fueron lixiviados en una solución de H2SO4(0,54 M a temperatura de 298 K. La concentración de Cu+2 en las soluciones fue determinada mediante espectrofotometría de absorción atómica. Los resultados obtenidos indicaron que el aumento del tiempo de molienda provoca un aumento en la recuperación de Cu, alcanzando un valor máximo de 38,2 % para una molienda de 15 h.

  3. Boundary-layer processes: key findings from MATERHORN-X field campaigns

    Science.gov (United States)

    Di Sabatino, Silvana; Leo, Laura S.; Pardyjak, Eric R.; Fernando, Harindra JS

    2017-04-01

    Understanding of atmospheric boundary-layer processes in complex terrain continues to be an active area of research considering its profound implications on numerical weather prediction (WP). It is largely recognized that nocturnal circulation, non-stationary processes involved in evening and morning transitions as well gusty conditions near mountains are poorly captured by current WP models. The search for novel understanding of boundary-layer phenomena especially in critical conditions for WP models has been one of the goals of the interdisciplinary Mountain Terrain Atmospheric Modeling and Observations (MATERHORN) program (2011-2016). The program developed with four main pillars: modelling (MATERHORN-M), experiments (MATERHORN-X), technology (MATERHORN-T), and parameterizations (MATERHORN-P), all synergistically working to meet new scientific challenges, address them effectively through dedicated field and laboratory studies, and transfer the acquired knowledge for model improvements. Specifically, MATERHORN-X is at the core of the MATERHORN program. It was built upon two major field experiments carried out in 31 September-October 2012 and in May 2013 at the Granite Mountain Atmospheric Science Testbed 32 (GMAST) of the Dugway Proving Ground (DPG). In this talk we will focus on results of data analyses from MATERHORN-X with emphasis on several aspects of the nocturnal circulation under low synoptic forcing when stable stratification occurs. The first part of the talk will discuss the evolution of nocturnal flows including both evening transitions on slopes and valleys as well as the occurrence of isolated flow bursts under very stable conditions. As far as the former is concerned we report on our latest understanding of mechanisms leading to evening transitions (e.g. shadow front, slab flow, and transitional front). As far as the latter is concerned, it is hypothesized that a link exists between isolated bursts in turbulent kinetic energy and low-level jets

  4. Mechanical properties of API X80 steel pipe joints welded by Flux Core Arc Weld Process; Propriedades mecanicas de juntas de tubos de aco API X80 soldadas com arame tubulares

    Energy Technology Data Exchange (ETDEWEB)

    Ordonez, Robert E. Cooper; Silva, Jose Hilton F.; Trevisan, Roseana E. [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Mecanica. Dept. de Engenharia de Fabricacao

    2003-07-01

    Flux Core Arc Welding processes (FCAW) are beginning to be applied in pipeline welds, however, very limited experimental data regarding mechanical properties of pipeline weld joints with these processes are available in the literature. In this paper, the effects of preheat temperature and type of FCAW on mechanical properties (microhardness and tensile strength) of API X80 weld joint steel are presented. FCAW processes with gas protection and self-shielded were used. Multipasses welding were applied in 30'' diameter and 0,625'' thickness tubes. Influence factors were: FCAW type and preheat temperature. Acceptance criteria of welded joints were evaluated by API 1104 standard for tensile strength test and ASTM E384-99 for microhardness test. The results obtained showed that FCAW type and preheat temperature have no influence on mechanical properties of API X80 joint steel. (author)

  5. X-ray scattering studies of non-equilibrium ordering processes: Progress report, November 1, 1988--October 31, 1989

    International Nuclear Information System (INIS)

    Nagler, S.E.

    1989-01-01

    We report on the progress of our project entitled ''X-ray Scattering Studies of Non-Equilibrium Ordering Processes.'' In-house time-resolved x-ray scattering has been used to investigate ordering kinetics in single crystal thin films of Cu 3 Au. Scaling analysis of the results shows that two dimensional kinetic behavior is observed in 260 /angstrom/ thick films. Significant improvements have been made in the local capabilities for fast time resolved measurements and data analysis. Measurements of microphase separation and ordering kinetics have been made in block-co-polymers, and experiments on Au-Cd martensitic material are continuing. 15 refs., 7 figs

  6. REHABILITACIÓN DE SUELOS SALINO-SÓDICOS: ESTUDIO DE CASO EN EL DISTRITO DE RIEGO 086, JIMÉNEZ, TAMAULIPAS, MÉXICO

    Directory of Open Access Journals (Sweden)

    Juana Irma Manzano Banda

    2014-07-01

    Full Text Available Se evaluó el efecto de la aplicación de estiércol bovino, yeso, ácido sulfúrico y lavado de suelos sobre la concentración de sales solubles y proporción de sodio en dos suelos salino-sódicos, provenientes del Distrito de Riego 086 de Jiménez, Tamaulipas, México. Se utilizaron macetas con 6 kg de suelo bajo condiciones de invernadero para ensayar dos niveles de salinidad-sodicidad (suelo Carretas con nivel moderado y suelo Macahuistle con nivel alto, dos mejoradores inorgánicos (yeso y ácido sulfúrico y un mejorador orgánico (estiércol. Se utilizó un diseño experimental completamente al azar con arreglo factorial 2 × 2 × 3. Las variables de respuesta fueron conductividad eléctrica (CE, porciento de sodio intercambiable (PSI y pH. La salinidad inicial en el suelo Carretas, con CE = 7.75 dS m-1 y Macahuistle con CE = 22.2 dS m-1, disminuyó a menos de 4 dS m-1. El PSI inicial del suelo Carretas fue 18.4 y el del suelo Macahuistle 34, valores que se abatieron a niveles menores de 8. El pH inicial de 7.8 en el suelo Carretas y 8 en el suelo Macahuistle, disminuyeron a un valor de 7.4 con la aplicación de estiércol y ácido sulfúrico. El lavado redujo la salinidad y sodicidad de ambos suelos hasta niveles satisfactorios para cultivos convencionales, con y sin de la aplicación de estiércol bovino, yeso y ácido sulfúrico.

  7. An instrument for in situ time-resolved X-ray imaging and diffraction of laser powder bed fusion additive manufacturing processes

    Science.gov (United States)

    Calta, Nicholas P.; Wang, Jenny; Kiss, Andrew M.; Martin, Aiden A.; Depond, Philip J.; Guss, Gabriel M.; Thampy, Vivek; Fong, Anthony Y.; Weker, Johanna Nelson; Stone, Kevin H.; Tassone, Christopher J.; Kramer, Matthew J.; Toney, Michael F.; Van Buuren, Anthony; Matthews, Manyalibo J.

    2018-05-01

    In situ X-ray-based measurements of the laser powder bed fusion (LPBF) additive manufacturing process produce unique data for model validation and improved process understanding. Synchrotron X-ray imaging and diffraction provide high resolution, bulk sensitive information with sufficient sampling rates to probe melt pool dynamics as well as phase and microstructure evolution. Here, we describe a laboratory-scale LPBF test bed designed to accommodate diffraction and imaging experiments at a synchrotron X-ray source during LPBF operation. We also present experimental results using Ti-6Al-4V, a widely used aerospace alloy, as a model system. Both imaging and diffraction experiments were carried out at the Stanford Synchrotron Radiation Lightsource. Melt pool dynamics were imaged at frame rates up to 4 kHz with a ˜1.1 μm effective pixel size and revealed the formation of keyhole pores along the melt track due to vapor recoil forces. Diffraction experiments at sampling rates of 1 kHz captured phase evolution and lattice contraction during the rapid cooling present in LPBF within a ˜50 × 100 μm area. We also discuss the utility of these measurements for model validation and process improvement.

  8. Microfocussing of synchrotron X-rays using X-ray refractive lens developed at Indus-2 deep X-ray lithography beamline

    International Nuclear Information System (INIS)

    Dhamgaye, V.P.; Tiwari, M.K.; Lodha, G.S.; Sawhney, K.J.S.

    2014-01-01

    X-ray lenses are fabricated in polymethyl methacrylate using deep X-ray lithography beamline of Indus-2. The focussing performance of these lenses is evaluated using Indus-2 and Diamond Light Source Ltd. The process steps for the fabrication of X-ray lenses and microfocussing at 10 keV at moderate and low emittance sources are compared. (author)

  9. X-ray fluorescence imaging with polycapillary X-ray optics

    International Nuclear Information System (INIS)

    Yonehara, Tasuku; Yamaguchi, Makoto; Tsuji, Kouichi

    2010-01-01

    X-ray fluorescence spectrometry imaging is a powerful tool to provide information about the chemical composition and elemental distribution of a specimen. X-ray fluorescence spectrometry images were conventionally obtained by using a μ-X-ray fluorescence spectrometry spectrometer, which requires scanning a sample. Faster X-ray fluorescence spectrometry imaging would be achieved by eliminating the process of sample scanning. Thus, we developed an X-ray fluorescence spectrometry imaging instrument without sample scanning by using polycapillary X-ray optics, which had energy filter characteristics caused by the energy dependence of the total reflection phenomenon. In the present paper, we show that two independent straight polycapillary X-ray optics could be used as an energy filter of X-rays for X-ray fluorescence. Only low energy X-rays were detected when the angle between the two optical axes was increased slightly. Energy-selective X-ray fluorescence spectrometry images with projection mode were taken by using an X-ray CCD camera equipped with two polycapillary optics. It was shown that Fe Kα (6.40 keV) and Cu Kα (8.04 keV) could be discriminated for Fe and Cu foils.

  10. Complementary X-ray and neutron radiography study of the initial lithiation process in lithium-ion batteries containing silicon electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Fu, E-mail: fu.sun@helmholtz-berlin.de [Institute of Material Science and Technologies, Technical University Berlin, 10623 Berlin (Germany); Helmholtz Centre Berlin for Materials and Energy, Hahn-Meitner-Platz 1, 14109 Berlin (Germany); Markötter, Henning [Institute of Material Science and Technologies, Technical University Berlin, 10623 Berlin (Germany); Helmholtz Centre Berlin for Materials and Energy, Hahn-Meitner-Platz 1, 14109 Berlin (Germany); Manke, Ingo; Hilger, André [Helmholtz Centre Berlin for Materials and Energy, Hahn-Meitner-Platz 1, 14109 Berlin (Germany); Alrwashdeh, Saad S. [Institute of Material Science and Technologies, Technical University Berlin, 10623 Berlin (Germany); Helmholtz Centre Berlin for Materials and Energy, Hahn-Meitner-Platz 1, 14109 Berlin (Germany); Mechanical Engineering Department, Faculty of Engineering, Mu' tah University, P.O. Box 7, Al-Karak 61710 Jordan (Jordan); Kardjilov, Nikolay [Helmholtz Centre Berlin for Materials and Energy, Hahn-Meitner-Platz 1, 14109 Berlin (Germany); Banhart, John [Institute of Material Science and Technologies, Technical University Berlin, 10623 Berlin (Germany); Helmholtz Centre Berlin for Materials and Energy, Hahn-Meitner-Platz 1, 14109 Berlin (Germany)

    2017-03-31

    Highlights: • A radiography cell for in operando X-ray radiography was designed and built. • A self-assembled CR2032 coin cell was built for in operando neutron radiography. • In operando X-ray and neuron radiography were conducted by using Si electrode half cells. - Abstract: Complementary in operando X-ray radiography and neutron radiography measurements were conducted to investigate and visualize the initial lithiation in silicon-electrode lithium-ion batteries. By means of X-ray radiography, a significant volume expansion of Si particles and the Si electrode during the first discharge was observed. In addition, many Si particles were found that never undergo electrochemical reactions. These findings were confirmed by neutron radiography, which, for the first time, showed the process of Li alloying with the Si electrode during initial lithiation. These results demonstrate that complementary X-ray and neutron radiography is a powerful tool to investigate the lithiation mechanisms inside Si-electrode based lithium-ion batteries.

  11. Effects of processing parameters on the morphology, structure, and magnetic properties of Cu{sub 1−x}Fe{sub x}Cr{sub 2}Se{sub 4} nanoparticles synthesized with chemical methods

    Energy Technology Data Exchange (ETDEWEB)

    Ivantsov, R.D. [Kirensky Institute of Physics, Russian Academy of Sciences, Krasnoyarsk, 660036 (Russian Federation); Edelman, I.S., E-mail: ise@iph.krasn.ru [Kirensky Institute of Physics, Russian Academy of Sciences, Krasnoyarsk, 660036 (Russian Federation); Zharkov, S.M.; Velikanov, D.A. [Kirensky Institute of Physics, Russian Academy of Sciences, Krasnoyarsk, 660036 (Russian Federation); Siberian Federal University, Krasnoyarsk, 660041 (Russian Federation); Petrov, D.A. [Kirensky Institute of Physics, Russian Academy of Sciences, Krasnoyarsk, 660036 (Russian Federation); Ovchinnikov, S.G. [Kirensky Institute of Physics, Russian Academy of Sciences, Krasnoyarsk, 660036 (Russian Federation); Siberian Federal University, Krasnoyarsk, 660041 (Russian Federation); Lin, Chun-Rong [National Pingtung University, Pingtung City, Pingtung County, 90003, Taiwan (China); Li, Oksana [Siberian Federal University, Krasnoyarsk, 660041 (Russian Federation); National Pingtung University, Pingtung City, Pingtung County, 90003, Taiwan (China); Tseng, Yaw-Teng [National Pingtung University, Pingtung City, Pingtung County, 90003, Taiwan (China)

    2015-11-25

    Cu{sub 1−x}Fe{sub x}Cr{sub 2}Se{sub 4} nanoparticles with x = 0, 0.2, and 0.4 were synthesized via thermal decomposition of metal nitrate or chloride salts and selenium powder using different precursor compositions and processing details. Single crystalline nano-belts or nano-rods coexist in the synthesized powder samples with hexagon-shaped plates in dependence on the precursor composition. The belts gathered into conglomerates forming “hierarchical” particles. Visible magnetic circular dichroism (MCD) of Cu{sub 1−x}Fe{sub x}Cr{sub 2}Se{sub 4} nanoparticles embedded into a transparent matrix was investigated for the first time. The similarity of the MCD spectra of all samples showed the similarity of the nanoparticles electronic structure independent of their morphology. Basing on the MCD spectral maxima characteristics, electron transitions from the ground to the excited states were identified with the help of the conventional band theory and the multi-electron approach. - Highlights: • Single crystalline Cu{sub 1−x}Fe{sub x}Cr{sub 2}Se{sub 4} nanoparticles with x = 0, 0.2, 0.4 were synthesized. • Correlation between synthesis conditions and nanoparticles morphology were obtained. • The nanoparticles magnetization behavior was studied. • Visible MCD of the Cu{sub 1−x}Fe{sub x}Cr{sub 2}Se{sub 4} nanoparticles were studied for the first time.

  12. Non-thermal Processes in Colliding-wind Massive Binaries: the Contribution of Simbol-X to a Multiwavelength Investigation

    Science.gov (United States)

    De Becker, Michaël; Blomme, Ronny; Micela, Giusi; Pittard, Julian M.; Rauw, Gregor; Romero, Gustavo E.; Sana, Hugues; Stevens, Ian R.

    2009-05-01

    Several colliding-wind massive binaries are known to be non-thermal emitters in the radio domain. This constitutes strong evidence for the fact that an efficient particle acceleration process is at work in these objects. The acceleration mechanism is most probably the Diffusive Shock Acceleration (DSA) process in the presence of strong hydrodynamic shocks due to the colliding-winds. In order to investigate the physics of this particle acceleration, we initiated a multiwavelength campaign covering a large part of the electromagnetic spectrum. In this context, the detailed study of the hard X-ray emission from these sources in the SIMBOL-X bandpass constitutes a crucial element in order to probe this still poorly known topic of astrophysics. It should be noted that colliding-wind massive binaries should be considered as very valuable targets for the investigation of particle acceleration in a similar way as supernova remnants, but in a different region of the parameter space.

  13. Acquisition and Merger Process Through the Eyes of Employees : A Case Study on How Change Management and Integration Process Affected the Employees of Company X

    OpenAIRE

    Maidell, Terhi

    2015-01-01

    This study is a case study about acquisition and merger process, which took place in February 2014, when Company X(name changed) bought three magazines and 42 employees were transferred from Company Y (name changed). The topic covers such issues as; change management during acquisition and merger from the employees’ point of view, how employees react to change and how they experience the change management process. The aim of the study is to understand the employee side of the story during cha...

  14. Aproximación de las expresiones cinéticas en las estapas de pretratamiento ácido y basico del bagazo

    OpenAIRE

    Granado Ojito, Jany; Cornes Izquierdo, Yaniset; Albernas Carvajal, Yailet; Corsano, Gabriela; Gonzalez Suarez, Erenio; Santos, Ronaldo; Mesa, Leyanis

    2016-01-01

    Se presenta la determinación de las expresiones de velocidad de la hidrólisis ácida del bagazo de caña de azúcar empleando ácido sulfúrico, obteniendo así el modelo cinético aproximado. Para el diseño experimental del pretratamiento ácido se elaboró un diseño factorial 22 , variando la temperatura de reacción (175-185ºC) y la concentración de ácido sulfúrico (0-1.25 %). Para el pretratamiento básico se elaboró un diseño factorial 23 , con una temperatura de reacción (175-195ºC), una concentra...

  15. X-ray Absorption Spectroscopy Characterization of Electrochemical Processes in Renewable Energy Storage and Conversion Devices

    Energy Technology Data Exchange (ETDEWEB)

    Farmand, Maryam [George Washington Univ., Washington, DC (United States)

    2013-05-19

    The development of better energy conversion and storage devices, such as fuel cells and batteries, is crucial for reduction of our global carbon footprint and improving the quality of the air we breathe. However, both of these technologies face important challenges. The development of lower cost and better electrode materials, which are more durable and allow more control over the electrochemical reactions occurring at the electrode/electrolyte interface, is perhaps most important for meeting these challenges. Hence, full characterization of the electrochemical processes that occur at the electrodes is vital for intelligent design of more energy efficient electrodes. X-ray absorption spectroscopy (XAS) is a short-range order, element specific technique that can be utilized to probe the processes occurring at operating electrode surfaces, as well for studying the amorphous materials and nano-particles making up the electrodes. It has been increasingly used in recent years to study fuel cell catalysts through application of the and #916; and mgr; XANES technique, in combination with the more traditional X-ray Absorption Near Edge Structure (XANES) and Extended X-ray Absorption Fine Structure (EXAFS) techniques. The and #916; and mgr; XANES data analysis technique, previously developed and applied to heterogeneous catalysts and fuel cell electrocatalysts by the GWU group, was extended in this work to provide for the first time space resolved adsorbate coverages on both electrodes of a direct methanol fuel cell. Even more importantly, the and #916; and mgr; technique was applied for the first time to battery relevant materials, where bulk properties such as the oxidation state and local geometry of a cathode are followed.

  16. X rays and condensed matter

    International Nuclear Information System (INIS)

    Daillant, J.

    1997-01-01

    After a historical review of the discovery and study of X rays, the various interaction processes between X rays and matter are described: Thomson scattering, Compton scattering, X-photon absorption through photoelectric effect, and magnetic scattering. X ray sources such as the European Synchrotron Radiation Facility (ESRF) are described. The various X-ray applications are presented: imagery such as X tomography, X microscopy, phase contrast; X-ray photoelectron spectroscopy and X-ray absorption spectroscopy; X-ray scattering and diffraction techniques

  17. Duodenal X-ray diagnostics

    International Nuclear Information System (INIS)

    Scheppach, W.

    1982-01-01

    The publication provides an overview of duodenal X-ray diagnostics with the aid of barium meals in 1362 patients. The introducing paragraphs deal with the topographic anatomy of the region and the methodics of X-ray investigation. The chapter entitled ''processes at the duodenum itself'' describes mainly ulcers, diverticula, congenital anomalies, tumors and inflammations. The neighbourhood processes comprise in the first place diseases having their origin at the pancreas and bile ducts. As a conclusion, endoscopic rectograde cholangio-pancreaticography and percutaneous transhepatic cholangiography are pointed out as advanced X-ray investigation methods. In the annex of X-ray images some of the described phenomena are shown in exemplary manner. (orig./MG) [de

  18. Effect of processing on the microstructure of finger millet by X-ray diffraction and scanning electron microscopy.

    Science.gov (United States)

    Dharmaraj, Usha; Parameswara, P; Somashekar, R; Malleshi, Nagappa G

    2014-03-01

    Finger millet is one of the important minor cereals, and carbohydrates form its major chemical constituent. Recently, the millet is processed to prepare hydrothermally treated (HM), decorticated (DM), expanded (EM) and popped (PM) products. The present research aims to study the changes in the microstructure of carbohydrates using X-ray diffraction and scanning electron microscopy. Processing the millet brought in significant changes in the carbohydrates. The native millet exhibited A-type pattern of X-ray diffraction with major peaks at 2θ values of 15.3, 17.86 and 23.15°, whereas, all other products showed V-type pattern with single major peak at 2θ values ranging from 19.39 to 19.81°. The corresponding lattice spacing and the number of unit cells in a particular direction of reflection also reduced revealing that crystallinity of starch has been decreased depending upon the processing conditions. Scanning electron microscopic studies also revealed that the orderly pattern of starch granules changed into a coherent mass due to hydrothermal treatment, while high temperature short time treatment rendered a honey-comb like structure to the product. However, the total carbohydrates and non-starch polysaccharide contents almost remained the same in all the products except for DM and EM, but the individual carbohydrate components changed significantly depending on the type of processing.

  19. TIN-X

    DEFF Research Database (Denmark)

    Cannon, Daniel C; Yang, Jeremy J; Mathias, Stephen L

    2017-01-01

    between proteins and diseases, based on text mining data processed from scientific literature. In the current implementation, TIN-X supports exploration of data for G-protein coupled receptors, kinases, ion channels, and nuclear receptors. TIN-X supports browsing and navigating across proteins......Motivation: The increasing amount of peer-reviewed manuscripts requires the development of specific mining tools to facilitate the visual exploration of evidence linking diseases and proteins. Results: We developed TIN-X, the Target Importance and Novelty eXplorer, to visualize the association...

  20. Genetic and immunohistochemical analysis of HSPA5 in mouse and human retinas.

    Science.gov (United States)

    Chintalapudi, Sumana R; Wang, XiaoFei; Li, Huiling; Lau, Yin H Chan; Williams, Robert W; Jablonski, Monica M

    2016-01-01

    Photoreceptor degenerative diseases are among the leading causes of vision loss. Although the causative genetic mutations are often known, mechanisms leading to photoreceptor degeneration remain poorly defined. We have previously demonstrated that the photoreceptor membrane-associated protein XAP-1 antigen is a product of the HSPA5 gene. In this study, we used systems genetic methods, statistical modeling, and immunostaining to identify and analyze candidate genes that modulate Hspa5 expression in the retina. Quantitative trait locus (QTL) mapping was used to map the genomic region that regulates Hspa5 in the cross between C57BL/6J X DBA/2J mice (BXD) genetic reference panel. The stepwise refinement of candidate genes was based on expression QTL mapping, gene expression correlation analyses (direct and partial), and analysis of regional sequence variants. The subcellular localization of candidate proteins and HSPA5 in mouse and human retinas was evaluated by immunohistochemistry. Differences in the localization of extracellular HSPA5 were assessed between healthy human donor and atrophic age-related macular degeneration (AMD) donor eyes. In the eyes of healthy mice, extracellular HSPA5 was confined to the area around the cone photoreceptor outer segments. Mapping variation in Hspa5 mRNA expression levels in the retina revealed a statistically significant trans -acting expression QTL (eQTL) on Chromosome 2 (Chr 2) and a suggestive locus on Chr 15. Sulf2 on Chr 2 was the strongest candidate gene based on partial correlation analysis, Pearson correlation with Hspa5 , expression levels in the retina, a missense variant in exon 14, and its reported function in the extracellular matrix and interphotoreceptor matrix. SULF2 is localized to the rod and cone photoreceptors in both human and mouse retinas. In human retinas with no pathology, extracellular HSPA5 was localized around many cones within the macular area. In contrast, fewer HSPA5-immunopositive cones were

  1. The appearance of Ti{sup 3+} states in solution-processed TiO{sub x} buffer layers in inverted organic photovoltaics

    Energy Technology Data Exchange (ETDEWEB)

    Zhidkov, Ivan S.; Kurmaev, Ernst Z.; Kukharenko, Andrey I.; Korotin, Danila M. [M. N. Mikheev Institute of Metal Physics, Russian Academy of Sciences-Ural Branch, S. Kovalevskoi Str. 18, 620990 Yekaterinburg (Russian Federation); Institute of Physics and Technology, Ural Federal University, Mira Str. 19, 620002 Yekaterinburg (Russian Federation); McLeod, John A., E-mail: jmcleod@suda.edu.cn [Institute of Functional Nano and Soft Materials (FUNSOM), Jiangsu Key Laboratory for Carbon-Based Functional Materials and Devices, Soochow University, 199 Ren' ai Road, Suzhou, 215123, Jiangsu (China); Korotin, Michael A. [M. N. Mikheev Institute of Metal Physics, Russian Academy of Sciences-Ural Branch, S. Kovalevskoi Str. 18, 620990 Yekaterinburg (Russian Federation); Savva, Achilleas; Choulis, Stelios A. [Molecular Electronics and Photonics Research Unit, Department of Mechanical Engineering and Materials Science and Engineering, Cyprus University of Technology, Kitiou Kiprianou Str. 45, 3603 Limassol (Cyprus); Cholakh, Seif O. [Institute of Physics and Technology, Ural Federal University, Mira Str. 19, 620002 Yekaterinburg (Russian Federation)

    2016-07-11

    We study the low-temperature solution processed TiO{sub x} films and device structures using core level and valence X-ray photoelectron spectroscopy (XPS) and electronic structure calculations. We are able to correlate the fraction of Ti{sup 3+} present as obtained from Ti 2p core level XPS with the intensity of the defect states that appear within the band gap as observed with our valence XPS. Constructing an operating inverted organic photovoltaic (OPV) using the TiO{sub x} film as an electron selective contact may increase the fraction of Ti{sup 3+} present. We provide evidence that the number of charge carriers in TiO{sub x} can be significantly varied and this might influence the performance of inverted OPVs.

  2. X-ray spectroscopy studies of nonradiative energy transfer processes in luminescent lanthanide materials

    Science.gov (United States)

    Pacold, Joseph I.

    Luminescent materials play important roles in energy sciences, through solid state lighting and possible applications in solar energy utilization, and in biomedical research and applications, such as in immunoassays and fluorescence microscopy. The initial excitation of a luminescent material leads to a sequence of transitions between excited states, ideally ending with the emission of one or more optical-wavelength photons. It is essential to understand the microscopic physics of this excited state cascade in order to rationally design materials with high quantum efficiencies or with other fine-tuning of materials response. While optical-wavelength spectroscopies have unraveled many details of the energy transfer pathways in luminescent materials, significant questions remain open for many lanthanide-based luminescent materials. For organometallic dyes in particular, quantum yields remain limited in comparison with inorganic phosphors. This dissertation reports on a research program of synchrotron x-ray studies of the excited state electronic structure and energy-relaxation cascade in trivalent lanthanide phosphors and dyes. To this end, one of the primary results presented here is the first time-resolved x-ray absorption near edge spectroscopy studies of the transient 4f excited states in lanthanide-activated luminescent dyes and phosphors. This is a new application of time-resolved x-ray absorption spectroscopy that makes it possible to directly observe and, to some extent, quantify intramolecular nonradiative energy transfer processes. We find a transient increase in 4f spectral weight associated with an excited state confined to the 4f shell of trivalent Eu. This result implies that it is necessary to revise the current theoretical understanding of 4f excitation in trivalent lanthanide activators: either transient 4f-5d mixing effects are much stronger than previously considered, or else the lanthanide 4f excited state has an unexpectedly large contribution

  3. Microstructure within domains of melt-processed YBa2Cu3O7-x superconductors

    International Nuclear Information System (INIS)

    Alexander, K.B.; Goyal, A.; Kroeger, D.M.; Selvamanickam, V.; Salama, K.

    1992-01-01

    The microstructure within single domains of melt-processed YBa 2 Cu 3 O 7-x (1:2:3) material has been examined. Rather than composing a ''brick-wall'' structure, the stacked, parallel platelets within the domains are actually portions of a single crystal. A growth mechanism is proposed that is consistent with the observed microstructural features. The anisotropic nature of the growth of 1:2:3 results in gaps separating the platelets. The gaps, however, terminate within domains, resulting in interconnected single-crystalline material. The absence of weak-link behavior for current flow along the c axis and the high critical-current densities observed within domains of melt-processed 1:2:3 material are readily explained by the fact that current flow is solely through single-crystalline material

  4. Quantitative analysis of flow processes in a sand using synchrotron-based X-ray microtomography

    DEFF Research Database (Denmark)

    Wildenschild, Dorthe; Hopmans, J.W.; Rivers, M.L.

    2005-01-01

    been of a mostly qualitative nature and no experiments have been presented in the existing literature where a truly quantitative approach to investigating the multiphase flow process has been taken, including a thorough image-processing scheme. The tomographic images presented here show, both......Pore-scale multiphase flow experiments were developed to nondestructively visualize water flow in a sample of porous material using X-ray microtomography. The samples were exposed to similar boundary conditions as in a previous investigation, which examined the effect of initial flow rate...... by qualitative comparison and quantitative analysis in the form of a nearest neighbor analysis, that the dynamic effects seen in previous experiments are likely due to the fast and preferential drainage of large pores in the sample. Once a continuous drained path has been established through the sample, further...

  5. Modeling the X-ray Process, and X-ray Flaw Size Parameter for POD Studies

    Science.gov (United States)

    Koshti, Ajay M.

    2014-01-01

    Nondestructive evaluation (NDE) method reliability can be determined by a statistical flaw detection study called probability of detection (POD) study. In many instances, the NDE flaw detectability is given as a flaw size such as crack length. The flaw is either a crack or behaving like a crack in terms of affecting the structural integrity of the material. An alternate approach is to use a more complex flaw size parameter. The X-ray flaw size parameter, given here, takes into account many setup and geometric factors. The flaw size parameter relates to X-ray image contrast and is intended to have a monotonic correlation with the POD. Some factors such as set-up parameters, including X-ray energy, exposure, detector sensitivity, and material type that are not accounted for in the flaw size parameter may be accounted for in the technique calibration and controlled to meet certain quality requirements. The proposed flaw size parameter and the computer application described here give an alternate approach to conduct the POD studies. Results of the POD study can be applied to reliably detect small flaws through better assessment of effect of interaction between various geometric parameters on the flaw detectability. Moreover, a contrast simulation algorithm for a simple part-source-detector geometry using calibration data is also provided for the POD estimation.

  6. U(1) x U(1) x U(1) symmetry of the Kimura 3ST model and phylogenetic branching processes

    International Nuclear Information System (INIS)

    Bashford, J D; Jarvis, P D; Sumner, J G; Steel, M A

    2004-01-01

    An analysis of the Kimura 3ST model of DNA sequence evolution is given on the basis of its continuous Lie symmetries. The rate matrix commutes with a U(1) x U(1) x U(1) phase subgroup of the group GL(4) of 4 x 4 invertible complex matrices acting on a linear space spanned by the four nucleic acid base letters. The diagonal 'branching operator' representing speciation is defined, and shown to intertwine the U(1) x U(1) x U(1) action. Using the intertwining property, a general formula for the probability density on the leaves of a binary tree under the Kimura model is derived, which is shown to be equivalent to established phylogenetic spectral transform methods. (letter to the editor)

  7. Tech-X Corporation releases simulation code for solving complex problems in plasma physics : VORPAL code provides a robust environment for simulating plasma processes in high-energy physics, IC fabrications and material processing applications

    CERN Multimedia

    2005-01-01

    Tech-X Corporation releases simulation code for solving complex problems in plasma physics : VORPAL code provides a robust environment for simulating plasma processes in high-energy physics, IC fabrications and material processing applications

  8. Hollow fiber contractors for simultaneous SO{sub x}/NO{sub x} removal

    Energy Technology Data Exchange (ETDEWEB)

    Bhown, A.S.; Pakala, N.R.; Riggs, T. [SRI International, Menlo Park, CA (United States)] [and others

    1995-11-01

    Control of SO{sub x} and NO{sub x} emissions from coal-fired utility and industrial boilers is a topic of growing national and international importance. Whereas a host of commercial and semicommercial processes exist, increasingly stringent emission standards mandate that processes be low cost, highly efficient, and, ideally, produce marketable byproducts. Although a wide range of site-specific economic factors dictate the best choice of SO{sub x} and NO{sub x} control, removal of SO{sub 2} by wet limestone scrubbing and removal of NO{sub x} by selective catalytic reduction (SCR) are regarded as the best commercialized technologies for this application. A typical wet limestone plant requires approximately $100 to $120 of capital investment per kilowatt of electric power generating capacity and has power and miscellaneous operating costs in the range of 5 to 6 mils per kilowatt hour (kWh). The SCR process requires approximately $70 to $100 of capital investment per kilowatt of electric power generating capacity. Its operating costs, including ammonia consumption, is in the range of 1.8 to 2.2 mils per kWh. These costs can add approximately 20% to the final cost of generated electricity, a significant burden on rate payers.

  9. Evaluation of noise limits to improve image processing in soft X-ray projection microscopy.

    Science.gov (United States)

    Jamsranjav, Erdenetogtokh; Kuge, Kenichi; Ito, Atsushi; Kinjo, Yasuhito; Shiina, Tatsuo

    2017-03-03

    Soft X-ray microscopy has been developed for high resolution imaging of hydrated biological specimens due to the availability of water window region. In particular, a projection type microscopy has advantages in wide viewing area, easy zooming function and easy extensibility to computed tomography (CT). The blur of projection image due to the Fresnel diffraction of X-rays, which eventually reduces spatial resolution, could be corrected by an iteration procedure, i.e., repetition of Fresnel and inverse Fresnel transformations. However, it was found that the correction is not enough to be effective for all images, especially for images with low contrast. In order to improve the effectiveness of image correction by computer processing, we in this study evaluated the influence of background noise in the iteration procedure through a simulation study. In the study, images of model specimen with known morphology were used as a substitute for the chromosome images, one of the targets of our microscope. Under the condition that artificial noise was distributed on the images randomly, we introduced two different parameters to evaluate noise effects according to each situation where the iteration procedure was not successful, and proposed an upper limit of the noise within which the effective iteration procedure for the chromosome images was possible. The study indicated that applying the new simulation and noise evaluation method was useful for image processing where background noises cannot be ignored compared with specimen images.

  10. Impaired spatial processing in a mouse model of fragile X syndrome.

    Science.gov (United States)

    Ghilan, Mohamed; Bettio, Luis E B; Noonan, Athena; Brocardo, Patricia S; Gil-Mohapel, Joana; Christie, Brian R

    2018-05-17

    Fragile X syndrome (FXS) is the most common form of inherited intellectual impairment. The Fmr1 -/y mouse model has been previously shown to have deficits in context discrimination tasks but not in the elevated plus-maze. To further characterize this FXS mouse model and determine whether hippocampal-mediated behaviours are affected in these mice, dentate gyrus (DG)-dependent spatial processing and Cornu ammonis 1 (CA1)-dependent temporal order discrimination tasks were evaluated. In agreement with previous findings of long-term potentiation deficits in the DG of this transgenic model of FXS, the results reported here demonstrate that Fmr1 -/y mice perform poorly in the DG-dependent metric change spatial processing task. However, Fmr1 -/y mice did not present deficits in the CA1-dependent temporal order discrimination task, and were able to remember the order in which objects were presented to them to the same extent as their wild-type littermate controls. These data suggest that the previously reported subregional-specific differences in hippocampal synaptic plasticity observed in the Fmr1 -/y mouse model may manifest as selective behavioural deficits in hippocampal-dependent tasks. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  11. Lobster eye X-ray optics: Data processing from two 1D modules

    Science.gov (United States)

    Nentvich, O.; Urban, M.; Stehlikova, V.; Sieger, L.; Hudec, R.

    2017-07-01

    The X-ray imaging is usually done by Wolter I telescopes. They are suitable for imaging of a small part of the sky, not for all-sky monitoring. This monitoring could be done by a Lobster eye optics which can theoretically have a field of view up to 360 deg. All sky monitoring system enables a quick identification of source and its direction. This paper describes the possibility of using two independent one-dimensional Lobster Eye modules for this purpose instead of Wolter I and their post-processing into an 2D image. This arrangement allows scanning with less energy loss compared to Wolter I or two-dimensional Lobster Eye optics. It is most suitable especially for very weak sources.

  12. Using soft-X-ray energy spectrum to measure electronic temperature Te and primary research with computer data processing

    International Nuclear Information System (INIS)

    Wang Jingyao; Zhang Guangyang

    1993-01-01

    The authors reported the application of SCORPIO--2000 Computer detecting system on a nuclear fusion equipment, to measure the energy spectrum of soft X-ray from which the plasma electronic temperature was calculated. The authors processed systematically the data of the energy area of 1-4 Kev soft X-ray. The program edited was mostly made in FORTRAN, but only one SUBSB was made in assembly language. The program worked normally with convincing operation and easy correction of the data. The result obtained from calculation is the same as what was expected and the diagram obtained is the same as the expected one

  13. Gaussian process tomography for soft x-ray spectroscopy at WEST without equilibrium information

    Science.gov (United States)

    Wang, T.; Mazon, D.; Svensson, J.; Li, D.; Jardin, A.; Verdoolaege, G.

    2018-06-01

    Gaussian process tomography (GPT) is a recently developed tomography method based on the Bayesian probability theory [J. Svensson, JET Internal Report EFDA-JET-PR(11)24, 2011 and Li et al., Rev. Sci. Instrum. 84, 083506 (2013)]. By modeling the soft X-ray (SXR) emissivity field in a poloidal cross section as a Gaussian process, the Bayesian SXR tomography can be carried out in a robust and extremely fast way. Owing to the short execution time of the algorithm, GPT is an important candidate for providing real-time reconstructions with a view to impurity transport and fast magnetohydrodynamic control. In addition, the Bayesian formalism allows quantifying uncertainty on the inferred parameters. In this paper, the GPT technique is validated using a synthetic data set expected from the WEST tokamak, and the results are shown of its application to the reconstruction of SXR emissivity profiles measured on Tore Supra. The method is compared with the standard algorithm based on minimization of the Fisher information.

  14. Radiation-induced defects and their recombination processes in the x-ray storage phosphor BaBr sub 2 :Eu sup 2 sup +

    CERN Document Server

    Secu, M; Rogulis, U; Spaeth, J M

    2003-01-01

    The recombination processes in the x-ray storage phosphor BaBr sub 2 :Eu sup 2 sup + were investigated by optical and magneto-optical methods. A structure-sensitive investigation of the defects involved in the recombination processes was performed by detecting the microwave-induced changes in the recombination luminescence in a high magnetic field. F centres as well as V sub K hole centres are created after x-irradiation at low temperatures. The low-energy recombination band peaking at about 460 nm is due to F-V sub K centre recombinations, whereas the two high energy bands at 282 and 315 nm are probably due to recombinations of self-trapped excitons.

  15. Modern X-ray spectroscopy 3. X-ray fluorescence holography

    International Nuclear Information System (INIS)

    Hayashi, Kouichi

    2008-01-01

    X-ray fluorescence holography (XFH) provides three dimensional atomic images around specified elements. The XFH uses atoms as a wave source or monitor of interference field within a crystal sample, and therefore it can record both intensity and phase of scattered X-rays. Its current performance makes it possible to apply to ultra thin film, impurity and quasicrystal. In this article, I show the theory including solutions for twin image problem, advanced measuring system, data processing for reconstruction of the atomic images and for obtaining accurate atomic positions, applications using resonant X-ray scattering and X-ray excited optical luminescence, and an example of XFH result on the local structure around copper in silicon steal. (author)

  16. Research of high speed data readout and pre-processing system based on xTCA for silicon pixel detector

    International Nuclear Information System (INIS)

    Zhao Jingzhou; Lin Haichuan; Guo Fang; Liu Zhen'an; Xu Hao; Gong Wenxuan; Liu Zhao

    2012-01-01

    As the development of the detector, Silicon pixel detectors have been widely used in high energy physics experiments. It needs data processing system with high speed, high bandwidth and high availability to read data from silicon pixel detectors which generate more large data. The same question occurs on Belle II Pixel Detector which is a new style silicon pixel detector used in SuperKEKB accelerator with high luminance. The paper describes the research of High speed data readout and pre-processing system based on xTCA for silicon pixel detector. The system consists of High Performance Computer Node (HPCN) based on xTCA and ATCA frame. The HPCN consists of 4XFPs based on AMC, 1 AMC Carrier ATCA Board (ACAB) and 1 Rear Transmission Module. It characterized by 5 high performance FPGAs, 16 fiber links based on RocketIO, 5 Gbit Ethernet ports and DDR2 with capacity up to 18GB. In a ATCA frame, 14 HPCNs make up a system using the high speed backplane to achieve the function of data pre-processing and trigger. This system will be used on the trigger and data acquisition system of Belle II Pixel detector. (authors)

  17. Progress on double-logarithmic large-x and small-x resummations for (semi-)inclusive hard processes

    International Nuclear Information System (INIS)

    Vogt, A.; Kom, C.H.; Lo Presti, N.A.; Soar, G.; Vermaseren, J.A.M.; Yeats, K.

    2012-12-01

    Over the past few years considerable progress has been made on the resummation of double-logarithmically enhanced threshold (large-x) and high-energy (small-x) higher-order contributions to the splitting functions for parton and fragmentation distributions and to the coefficient functions for inclusive deep-inelastic scattering and semi-inclusive e + e - annihilation. We present an overview of the methods which allow, in many cases, to derive the coefficients of the highest three logarithms at all orders in the strong coupling from next-to-next-to-leading order results in massless perturbative QCD. Some representative analytical and numerical results are shown, and the present limitations of these resummations are discussed.

  18. Dielectric properties of BNT-xBT prepared by hydrothermal process

    Directory of Open Access Journals (Sweden)

    Natheer B. Mahmood

    2017-06-01

    Full Text Available The BNT ceramic sample might be a good replacement for PZT piezoelectric in industrial applications, especially in energy harvesting from crystal vibrations. In order to enhance the performance of BNT ceramic, the solid solution was chosen by substitution with Ba+2 at Morphtropic Phase Boundary (MPB. The BNT-xBT powders with x=1, 0.07, 0.06 and 0 were prepared by the hydrothermal method with average particle size (65–150nm at (90∘C/72h. The ceramic disc was sintered at (1150∘C/4h and showed excellent relative density of about 96%. The results of X-ray diffraction (XRD confirmed the MPB for x=0.06 and 0.07, while the BNT had a rhombohedral structure and BT had a tetragonal structure. The dielectric measurements showed that BNT, BNT-7BT, BNT-6BT behave as the relaxator ferroelectric and showed a strong dependence on frequency, especially in the MPB region while BT behaves as a normal ferroelectric. Both the Curie temperature and depolarization temperature decrease at the MPB region and showed strong dependency on frequency.

  19. Research of the X-ray spectrum in the digital image acquisition and processing for internal disturbs detection in mangoes (Mangifera indica l.)

    International Nuclear Information System (INIS)

    Ferreira, Rubemar S.; Freire Junior, Murillo; Botrel, Neide; Jesus, Edgar de

    2002-01-01

    In this work, digital image processing was associated to X-ray beam relevant to watching internal injuries, such as breakdown, soft nose and other physiological disturbs in mangoes CV Tommy Atkins. The X-ray source was a high frequency generator operating to a high tension between 14 to 35 kV on a molybdenum target tube, which generate X-ray characteristic near from 18,5 keV and 20 keV (k an l shell) plus a continuous spectrum, thought to be proper to get radiological images from mangoes in different maturation stages. Different filtrations and pseudo-colors technique were used to process the digital images produced. Results, from a group of comparative images, show the feasibility to detect several classes of internal disorders as well as others produced in packing houses and transport of mangoes. (author)

  20. Small x physics

    International Nuclear Information System (INIS)

    Kwiecinski, J.

    1993-01-01

    The QCD expectations concerning the small x limit of parton distributions where x is the Bjorken scaling variable are reviewed. This includes discussion of the evolutions equations in the small x region, the Lipatov equation which sums the leading powers of ln(1/x) and the shadowing effects. Phenomenological implantations of the theoretical expectations for the deep inelastic lepton-hadron scattering in the small x region which will be accessible at the HERA ep collider are described. We give predictions for structure functions F 2 and F L and discuss specific processes sensitive to the small x physics such as heavy quark production, deep inelastic diffraction and jet production in deep inelastic lepton scattering. A brief review of nuclear shadowing in the inelastic lepton nucleus scattering at small x is also presented. (author). 86 refs, 29 figs

  1. Processing of the quench detection signals in W7-X

    International Nuclear Information System (INIS)

    Birus, Dietrich; Schneider, Matthias; Rummel, Thomas; Fricke, Marko; Petry, Klaus; Ebersoldt, Andreas

    2009-01-01

    The Wendelstein 7-X (W7-X) project uses superconductive coils for generation of the magnetic field to keep the plasma. One of the important safety systems is the protection against quench events. The quench detection system of W7-X protects the superconducting coils, the superconducting bus bar sections and the high temperature superconductor of the current leads against the damage because of a quench and against the high stress by a fast discharge of the magnet system. Therefore, the present design of the quench detection system (QDS) uses a two-stage safety concept for discharging the magnetic system. This paper describes the present design of the system assembly from the quench detection unit (QDU) for the detection of the quench to the quench detection interface (QDI) to implement the two-stage safety concept.

  2. Handbook of X-Ray Data

    CERN Document Server

    Zschornack, Günter

    2007-01-01

    This sourcebook is intended as an X-ray data reference for scientists and engineers working in the field of energy or wavelength dispersive X-ray spectrometry and related fields of basic and applied research, technology, or process and quality controlling. In a concise and informative manner, the most important data connected with the emission of characteristic X-ray lines are tabulated for all elements up to Z = 95 (Americium). This includes X-ray energies, emission rates and widths as well as level characteristics such as binding energies, fluorescence yields, level widths and absorption edges. The tabulated data are characterized and, in most cases, evaluated. Furthermore, all important processes and phenomena connected with the production, emission and detection of characteristic X-rays are discussed. This reference book addresses all researchers and practitioners working with X-ray radiation and fills a gap in the available literature.

  3. Progress on double-logarithmic large-x and small-x resummations for (semi-)inclusive hard processes

    Energy Technology Data Exchange (ETDEWEB)

    Vogt, A.; Kom, C.H.; Lo Presti, N.A.; Soar, G. [Liverpool Univ. (United Kingdom). Dept. of Mathematical Sciences; Almasy, A.A.; Moch, S. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Vermaseren, J.A.M. [NIKHEF Theory Group, Amsterdam (Netherlands); Yeats, K. [Simon Fraser Univ., Burnaby, BC (Canada). Dept. of Mathematics

    2012-12-15

    Over the past few years considerable progress has been made on the resummation of double-logarithmically enhanced threshold (large-x) and high-energy (small-x) higher-order contributions to the splitting functions for parton and fragmentation distributions and to the coefficient functions for inclusive deep-inelastic scattering and semi-inclusive e{sup +}e{sup -} annihilation. We present an overview of the methods which allow, in many cases, to derive the coefficients of the highest three logarithms at all orders in the strong coupling from next-to-next-to-leading order results in massless perturbative QCD. Some representative analytical and numerical results are shown, and the present limitations of these resummations are discussed.

  4. Low NO{sub x}/SO{sub x} Burner retrofit for utility cyclone boilers. Public design report

    Energy Technology Data Exchange (ETDEWEB)

    1991-09-01

    This Public Design Report provides available nonproprietary design information on the Low NO{sub x}SO{sub x} Burner Retrofit of Utility Cyclone Boilers project. In addition to the design aspects, the history of the project, the organization of the project, and the role of the funding parties are discussed. An overview of the Low NO{sub x}SO{sub x} (LNS) Burner, the cyclone boiler and the Southern Illinois Power Cooperative host site is presented. A detailed nonproprietary description of the individual process steps, plant systems, and resulting performance then follows. Narrative process descriptions, simplified process flow diagrams, input/output stream data, operating conditions and requirements are given for each unit. The plant demonstration program and start up provisions, the environmental considerations and control, monitoring and safety factors that are considered are also addressed.

  5. Concept development of X-ray mass thickness detection for irradiated items upon electron beam irradiation processing

    Science.gov (United States)

    Qin, Huaili; Yang, Guang; Kuang, Shan; Wang, Qiang; Liu, Jingjing; Zhang, Xiaomin; Li, Cancan; Han, Zhiwei; Li, Yuanjing

    2018-02-01

    The present project will adopt the principle and technology of X-ray imaging to quickly measure the mass thickness (wherein the mass thickness of the item =density of the item × thickness of the item) of the irradiated items and thus to determine whether the packaging size and inside location of the item will meet the requirements for treating thickness upon electron beam irradiation processing. The development of algorithm of X-ray mass thickness detector as well as the prediction of dose distribution have been completed. The development of the algorithm was based on the X-ray attenuation. 4 standard modules, Al sheet, Al ladders, PMMA sheet and PMMA ladders, were selected for the algorithm development. The algorithm was optimized until the error between tested mass thickness and standard mass thickness was less than 5%. Dose distribution of all energy (1-10 MeV) for each mass thickness was obtained using Monte-carlo method and used for the analysis of dose distribution, which provides the information of whether the item will be penetrated or not, as well as the Max. dose, Min. dose and DUR of the whole item.

  6. Generation of relativistic electron bunches in plasma synchrotron Gyrac-x for hard x-ray production

    International Nuclear Information System (INIS)

    Andreev, V.V.; Umnov, A.M.

    2000-01-01

    Experiment performed on plasma synchrotron Gyrac-X operating on synchrotron gyromagnetic autoresonance (SGA) is described. Gyrac-X is a compact plasma x-ray source in which kinetic energy of relativistic electrons obtained under SGA converts into x-ray by falling e-bunches on to a heavy metal target. The plasma synchrotron acts in a regime of a magnetic field pulse packet under constant level of microwave power. Experiments and numerical modeling of the process showed that such a regime allowed obtaining dense short lived relativistic electron bunches with average electron energy of 500 keV - 4.5 MeV. Parameters of the relativistic electron bunch (energy, density and volume) and dynamics of the electron bunches can be controlled by varying the parameters of the SGA process. Possibilities of x-ray intensity increase are also discussed

  7. New process of preparation, X-ray characterisation, structure and vibrational studies of a solid solution LiTiOAs 1-xP xO 4 (0⩽ x⩽1)

    Science.gov (United States)

    Chakir, M.; El Jazouli, A.; Chaminade, J. P.; Bouree, F.; de Waal, D.

    2006-01-01

    LiTiOAs 1-xP xO 4 (0⩽ x⩽1) compounds have been prepared using solutions of Li, Ti, As and P elements as starting products. Selected compositions have been investigated by powder X-ray or neutrons diffraction analysis, Raman and infrared spectroscopy. The structure of LiTiOAs 1-xP xO 4 ( x=0, 0.5 and 1) samples determined by Rietveld analysis is orthorhombic with Pnma space group. It is formed by a 3D network of TiO 6 octahedra and XO 4 ( X=As 1-xP x) tetrahedra where octahedral cavities are occupied by lithium atoms. TiO 6 octahedra are linked together by corners and form infinite chains along a-axis. Ti atoms are displaced from the centre of octahedral units in alternating short (1.700-1.709 Å) and long (2.301-2.275 Å) Ti-O bonds. Raman and infrared studies confirm the existence of Ti-O-Ti chains. Thermal stability of LiTiOAsO 4 has been reported.

  8. A Three-Step Atomic Layer Deposition Process for SiN x Using Si2Cl6, CH3NH2, and N2 Plasma.

    Science.gov (United States)

    Ovanesyan, Rafaiel A; Hausmann, Dennis M; Agarwal, Sumit

    2018-06-06

    We report a novel three-step SiN x atomic layer deposition (ALD) process using Si 2 Cl 6 , CH 3 NH 2 , and N 2 plasma. In a two-step process, nonhydrogenated chlorosilanes such as Si 2 Cl 6 with N 2 plasmas lead to poor-quality SiN x films that oxidize rapidly. The intermediate CH 3 NH 2 step was therefore introduced in the ALD cycle to replace the NH 3 plasma step with a N 2 plasma, while using Si 2 Cl 6 as the Si precursor. This three-step process lowers the atomic H content and improves the film conformality on high-aspect-ratio nanostructures as Si-N-Si bonds are formed during a thermal CH 3 NH 2 step in addition to the N 2 plasma step. During ALD, the reactive surface sites were monitored using in situ surface infrared spectroscopy. Our infrared spectra show that, on the post-N 2 plasma-treated SiN x surface, Si 2 Cl 6 reacts primarily with the surface -NH 2 species to form surface -SiCl x ( x = 1, 2, or 3) bonds, which are the reactive sites during the CH 3 NH 2 cycle. In the N 2 plasma step, reactive -NH 2 surface species are created because of the surface H available from the -CH 3 groups. At 400 °C, the SiN x films have a growth per cycle of ∼0.9 Å with ∼12 atomic percent H. The films grown on high-aspect-ratio nanostructures have a conformality of ∼90%.

  9. X-ray microscope with a Wolter mirror

    International Nuclear Information System (INIS)

    Watanabe, Norio; Aoki, Sadao

    2003-01-01

    A Wolter mirror as an objective of an X-ray microscope is described. In comparison with other optical elements, a Wolter mirror has several advantages, such as a large numerical aperture and no chromatic aberration. Recent developments of fabrication process enabled us to make a Wolter mirror objective for X-rays. The fabrication process and the applications to a soft X-ray microscope and an X-ray fluorescence microscope are described. (author)

  10. Soft x-ray scattering facility at the Advanced Light Source with real-time data processing and analysis

    Science.gov (United States)

    Gann, E.; Young, A. T.; Collins, B. A.; Yan, H.; Nasiatka, J.; Padmore, H. A.; Ade, H.; Hexemer, A.; Wang, C.

    2012-04-01

    We present the development and characterization of a dedicated resonant soft x-ray scattering facility. Capable of operation over a wide energy range, the beamline and endstation are primarily used for scattering from soft matter systems around the carbon K-edge (˜285 eV). We describe the specialized design of the instrument and characteristics of the beamline. Operational characteristics of immediate interest to users such as polarization control, degree of higher harmonic spectral contamination, and detector noise are delineated. Of special interest is the development of a higher harmonic rejection system that improves the spectral purity of the x-ray beam. Special software and a user-friendly interface have been implemented to allow real-time data processing and preliminary data analysis simultaneous with data acquisition.

  11. Soft x-ray scattering facility at the Advanced Light Source with real-time data processing and analysis

    International Nuclear Information System (INIS)

    Gann, E.; Collins, B. A.; Ade, H.; Young, A. T.; Nasiatka, J.; Padmore, H. A.; Hexemer, A.; Wang, C.; Yan, H.

    2012-01-01

    We present the development and characterization of a dedicated resonant soft x-ray scattering facility. Capable of operation over a wide energy range, the beamline and endstation are primarily used for scattering from soft matter systems around the carbon K-edge (∼285 eV). We describe the specialized design of the instrument and characteristics of the beamline. Operational characteristics of immediate interest to users such as polarization control, degree of higher harmonic spectral contamination, and detector noise are delineated. Of special interest is the development of a higher harmonic rejection system that improves the spectral purity of the x-ray beam. Special software and a user-friendly interface have been implemented to allow real-time data processing and preliminary data analysis simultaneous with data acquisition.

  12. R.E.S.E.X. A computer simulation program for rare earth separation processes

    International Nuclear Information System (INIS)

    Casarci, M.; Gasparini, G.M.; Sanfilippo, L; Pozio, A.

    1996-01-01

    Lanthanides are most commonly separated using complex solvent extraction circuits. A simulation code has been developed by E.N.E.A. called R.E.S.E.X. (Rare Earth Solvent Extraction) which is able to simulate a solvent extraction battery up to 200 stages, using different configurations. The contemporary utilisation of an equilibrium data bank and of a simulation code allows the theoretical study of new rare earth separative processes or the optimisation of existing ones. As an example of this strategy are reported the results of the Pr/Nd separation in TBP 50 % in aromatic solvent

  13. Pilot evaluation of a fracture process zone in a modified compact tension specimen by X-ray tomography

    Czech Academy of Sciences Publication Activity Database

    Klon, J.; Seitl, S.; Šimonová, H.; Keršner, Z.; Kumpová, Ivana; Vavřík, Daniel

    2017-01-01

    Roč. 42, October (2017), s. 161-169 ISSN 1971-8993 R&D Projects: GA ČR(CZ) GA15-07210S Keywords : fracture process zone * X-ray * concrete * composites * stress intensity factor * compact tension specimen Subject RIV: JL - Materials Fatigue, Friction Mechanics OBOR OECD: Mechanical engineering http://www.fracturae.com/index.php/fis/article/view/IGF-ESIS.42.17

  14. Microscopic bosonization of band structures: x-ray processes beyond the Fermi edge

    Science.gov (United States)

    Snyman, Izak; Florens, Serge

    2017-11-01

    Bosonization provides a powerful analytical framework to deal with one-dimensional strongly interacting fermion systems, which makes it a cornerstone in quantum many-body theory. However, this success comes at the expense of using effective infrared parameters, and restricting the description to low energy states near the Fermi level. We propose a radical extension of the bosonization technique that overcomes both limitations, allowing computations with microscopic lattice Hamiltonians, from the Fermi level down to the bottom of the band. The formalism rests on the simple idea of representating the fermion kinetic term in the energy domain, after which it can be expressed in terms of free bosonic degrees of freedom. As a result, one- and two-body fermionic scattering processes generate anharmonic boson-boson interactions, even in the forward channel. We show that up to moderate interaction strengths, these non-linearities can be treated analytically at all energy scales, using the x-ray emission problem as a showcase. In the strong interaction regime, we employ a systematic variational solution of the bosonic theory, and obtain results that agree quantitatively with an exact diagonalization of the original one-particle fermionic model. This provides a proof of the fully microscopic character of bosonization, on all energy scales, for an arbitrary band structure. Besides recovering the known x-ray edge singularity at the emission threshold, we find strong signatures of correlations even at emission frequencies beyond the band bottom.

  15. Tratabilidade de solos tropicais contaminados por resíduos da indústria de revestimentos cerâmicos Treatability of tropical soils contaminated by solid wastes from ceramic tile industry

    Directory of Open Access Journals (Sweden)

    Luciana Pena de Oliveira

    2008-03-01

    Full Text Available Este trabalho de pesquisa buscou investigar a eficácia da remoção de chumbo (Pb e zinco (Zn de uma área contaminada pelo depósito inadequado de resíduos de indústrias de revestimentos cerâmicos do pólo de Santa Gertrudes (São Paulo, Brasil, ocorrido há cerca de trinta anos atrás. Foram avaliados três processos de lixiviação: lavagem com ácido sulfúrico concentrado e por soluções de peróxido de hidrogênio a 30% e de ácido clorídrico 0,1 M. Os resultados obtidos mostraram que o tratamento com peróxido de hidrogênio não removeu Pb e Zn; que a lavagem com ácido sulfúrico concentrado promoveu a redução de 50% dos teores de Zn e a solução de ácido clorídrico 0,1 M reduziu os teores de Pb e Zn em 15% e 10%, respectivamente. O teor remanescente de Zn no solo tratado com ácido sulfúrico concentrado foi de 117 mg/kg e os de Pb e Zn no solo lavado com a solução de ácido clorídrico 0,1 M, de 806 mg/kg e 213 mg/kg, respectivamente, valores estes inferiores aos de intervenção estabelecidos pelo órgão de controle ambiental paulista.The aim of this research was to evaluate different leaching processes to the removal of lead (Pb and zinc (Zn from tropical soil contaminated by inappropriate past deposition of wastes from ceramic tile industries of Santa Gertrudes (São Paulo, Brazil. Three soil washing processes were investigated: with concentrated sulphuric acid, with a 30% solution of hydrogen peroxide and with 0.1M solution of hydrochloric acid. The results indicated that the treatment with hydrogen peroxide did not remove Pb and Zn significantly; the washing with concentrated sulphuric acid caused a 50% reduction of Zn contents and the 0.1M solution of hydrochloric acid reduced Pb and Zn contents in 15% and 10%, respectively. The Zn content remaining in the soil processed with concentrated sulphuric acid was 117 mg/kg and the Pb and Zn contents remaining in the soil processed with 0.1M solution of hydrochloric acid

  16. High density processing electronics for superconducting tunnel junction x-ray detector arrays

    Energy Technology Data Exchange (ETDEWEB)

    Warburton, W.K., E-mail: bill@xia.com [XIA LLC, 31057 Genstar Road, Hayward, CA 94544 (United States); Harris, J.T. [XIA LLC, 31057 Genstar Road, Hayward, CA 94544 (United States); Friedrich, S. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States)

    2015-06-01

    Superconducting tunnel junctions (STJs) are excellent soft x-ray (100–2000 eV) detectors, particularly for synchrotron applications, because of their ability to obtain energy resolutions below 10 eV at count rates approaching 10 kcps. In order to achieve useful solid detection angles with these very small detectors, they are typically deployed in large arrays – currently with 100+ elements, but with 1000 elements being contemplated. In this paper we review a 5-year effort to develop compact, computer controlled low-noise processing electronics for STJ detector arrays, focusing on the major issues encountered and our solutions to them. Of particular interest are our preamplifier design, which can set the STJ operating points under computer control and achieve 2.7 eV energy resolution; our low noise power supply, which produces only 2 nV/√Hz noise at the preamplifier's critical cascode node; our digital processing card that digitizes and digitally processes 32 channels; and an STJ I–V curve scanning algorithm that computes noise as a function of offset voltage, allowing an optimum operating point to be easily selected. With 32 preamplifiers laid out on a custom 3U EuroCard, and the 32 channel digital card in a 3U PXI card format, electronics for a 128 channel array occupy only two small chassis, each the size of a National Instruments 5-slot PXI crate, and allow full array control with simple extensions of existing beam line data collection packages.

  17. Synchronization of x-ray pulses to the pump laser in an ultrafast x-ray facility

    International Nuclear Information System (INIS)

    Corlett, J.N.; Barry, W.; Byrd, J.M.; Schoenlein, R.; Zholents, A.

    2002-01-01

    Accurate timing of ultrafast x-ray probe pulses emitted from a synchrotron radiation source with respect to a pump laser exciting processes in the sample under study is critical for the investigation of structural dynamics in the femtosecond regime. We describe a scheme for synchronizing femtosecond x-ray pulses relative to a pump laser. X-ray pulses of <100 fs duration are generated from a proposed source based on a recirculating superconducting linac [1,2,3]. Short x-ray pulses are obtained by a process of electron pulse compression, followed by transverse temporal correlation of the electrons, and ultimately x-ray pulse compression. Timing of the arrival of the x-ray pulse with respect to the pump laser is found to be dominated by the operation of the deflecting cavities which provide the transverse temporal correlation of the electrons. The deflecting cavities are driven from a highly stable RF signal derived from a modelocked laser oscillator which is also the origin of the pump l aser pulses

  18. Solar X-Ray Processes

    Science.gov (United States)

    Mallik, P. C. V.; Brown, J. C.; MacKinnon, A. L.

    Past analyses of solar flares have ignored nonthermal recombination (NTR) emission as a means of producing Hard X-rays (HXRs) in the corona and chromosphere. However, Brown and Mallik (2008, A&A, 481, 507) have shown that NTR can be significant and even exceed nonthermal bremsstrahlung (NTB) emission for certain flare conditions that are quite common. For hot enough plasma (T > 10 MK), HXR emission of a few deka-keV has a large contribution from NTR onto highly ionized heavy elements, especially Fe. Consequently, including NTR has implications for the magnitude and the form of the inferred electron spectrum, F(E), and hence for fast-electron density and energy budgets and for the acceleration mechanisms. We show under what circumstances NTR dominates in deka-keV HXR emission. It is important to note that at high temperatures, HXR emission from thermal electrons (recombination and bremsstrahlung) becomes important. However, NTR dominates over NTB without being swamped by thermal emission in the photon energy (ɛ) regime of 20-30 keV and temperature range of 10-25MK (Fig. 1, left). By integrating the flux for all ɛ > 20keV, i.e., looking at the source luminosity function above 20 keV, we were able to show that by including NTR, the acceleration requirements are less demanding for every event, but to varying degrees based on temperature (T), spectral index (δ) and electron low-energy cut-off (Ec). Our key result is that, for T > 10MK and δ ≈ 5, including NTR reduces the demand for nonthermal electrons by up to 85%. Our paper with these results will be submitted to ApJ Letters.

  19. Evidence for the Modulation of Sub-Lexical Processing in Go No-Go Naming: The Elimination of the Frequency x Regularity Interaction

    Science.gov (United States)

    Cummine, Jacqueline; Amyotte, Josee; Pancheshen, Brent; Chouinard, Brea

    2011-01-01

    The Frequency (high vs. low) x Regularity (regular vs. exception) interaction found on naming response times is often taken as evidence for parallel processing of sub-lexical and lexical systems. Using a Go/No-go naming task, we investigated the effect of nonword versus pseudohomophone foils on sub-lexical processing and the subsequent Frequency x…

  20. Effect of defect on the nonlinear and dielectric property of Ca(1–x)SrxCu3Ti4O12 ceramics synthesized by sol–gel process

    International Nuclear Information System (INIS)

    Li, Tao; Liu, Dewei; Dai, Haiyang; Xiang, Huiwen; Chen, Zhenping; He, Huifang; Chen, Zhiquan

    2014-01-01

    Highlights: • Ca (1−x) Sr x Cu 3 Ti 4 O 12 ceramics are synthesized by sol–gel process. • Positron annihilation lifetime spectra is used to investigate the defects of samples. • Nonlinear and dielectric properties are controlled by density and defects of samples. - Abstract: Ca (1−x) Sr x Cu 3 Ti 4 O 12 (x = 0, 0.05, 0.1, 0.15, 0.2, 0.3 and 0.4) ceramics are synthesized by sol–gel process. The XRD patterns show that weak peaks of Sr 4 Ti 3 O 10 , TiO 2 and Ca 1.7 Sr 0.3 CuO 3 begin to appear at x ⩾ 0.2. Sr-doping is conductive to increase the density and reduce the defect concentration Ca (1−x) Sr x Cu 3 Ti 4 O 12 ceramics as x ⩽ 0.15. With increasing x (0.2 ⩽ x ⩽ 0.4), Sr-doping reduces the density and enhances the concentration of defects for the ceramics. The nonlinear coefficient value increases and reaches a maximum 13.5 at x = 0.15, and then decreases gradually with increasing x. The dielectric properties demonstrate that, as x ⩽ 0.15, Sr-doping not only increases the dielectric permittivity value and decreases the dielectric loss but also reduces the dependence on frequency at low frequencies. With increasing x (0.2 ⩽ x ⩽ 0.4), Sr-doping begins to lead to an inverse result in dielectric behaviors. The nonlinear and dielectric properties of Ca (1−x) Sr x Cu 3 Ti 4 O 12 ceramics are directly controlled by the density and defects

  1. Process of radiation damage in BaFX:Eu2+ (X=Br, I) photo-stimulable phosphor for imaging plate (IP)

    International Nuclear Information System (INIS)

    Kato, Munetaka; Takahashi, Kenji

    2005-01-01

    Imaging Plate (IP) is a 2-dimensional radiation detector utilizing photo-stimulable phosphors. Photo-stimulated luminescence (PSL) is a kind of process in radiation-induced reactions and IP can be repeatedly performed. The mechanism of PSL is reviewed and the radiation damage, which is a phenomenon that the luminescence goes down under X-ray irradiation, is also referred to. The relation between the composition of BaFX: Eu 2+ (X=Br, I), which is widely used in IPs, and the degree of radiation damage is investigated. The degree of radiation damage is smaller in the mixed crystal system of Br and I such as BaFBr 0.85 I 0.15 :Eu 2+ than in BaFBr: Eu 2+ and BaFI: Eu 2+ . This is explained by the characteristics of luminescence centers and F centers under X-ray irradiation. (author)

  2. Nanostructure and magnetization reversal process in TbFeCo/Yx(FeCo)1-x spring-magnet type multilayers

    International Nuclear Information System (INIS)

    Duc, N.H.; Huong Giang, D.T.; Chau, N.

    2004-01-01

    Studies of the naturally formed nanostructure and magnetization reversal process were performed for the sputtered Tb(Fe 0.55 Co 0.45 ) 1.5 /Y x (Fe 0.7 Co 0.3 ) 1-x multilayers (0≤x≤0.2) with a TbFeCo layer thickness t TbFeCo =12 nm and YFeCo layer thickness t YFeCo =10 nm. The structural investigations showed that nanocrystals are naturally formed and coexist within the amorphous matrix in Y 0.1 (FeCo) 0.9 layers. In this state, low magnetic coercivity and large parallel magnetostrictive susceptibility are observed. The results are discussed in terms of the crystalline discontinuity of the soft YFeCo layers

  3. Application of Laser Plasma Sources of Soft X-rays and Extreme Ultraviolet (EUV) in Imaging, Processing Materials and Photoionization Studies

    Science.gov (United States)

    Fiedorowicz, H.; Bartnik, A.; Wachulak, P. W.; Jarocki, R.; Kostecki, J.; Szczurek, M.; Ahad, I. U.; Fok, T.; Szczurek, A.; Wȩgrzyński, Ł.

    In the paper we present new applications of laser plasma sources of soft X-rays and extreme ultraviolet (EUV) in various areas of plasma physics, nanotechnology and biomedical engineering. The sources are based on a gas puff target irradiated with nanosecond laser pulses from commercial Nd: YAG lasers, generating pulses with time duration from 1 to 10 ns and energies from 0.5 to 10 J at a 10 Hz repetition rate. The targets are produced with the use of a double valve system equipped with a special nozzle to form a double-stream gas puff target which allows for high conversion efficiency of laser energy into soft X-rays and EUV without degradation of the nozzle. The sources are equipped with various optical systems to collect soft X-ray and EUV radiation and form the radiation beam. New applications of these sources in imaging, including EUV tomography and soft X-ray microscopy, processing of materials and photoionization studies are presented.

  4. Saffron extracts effect on processes in brain structures under exposure to x-ray irradiation of medium dose

    International Nuclear Information System (INIS)

    Rzaeva, A.

    2012-01-01

    Full text : Process of ionizing radiation on live organism is accompanied by interaction of free radicals (FR) with molecules of proteins, nucleic acids and lipids. In its turn, FR occurs subsequently by excitation and ionization of molecules. Besides all, ionizing radiation becomes the reason of accumulation in body tissues of toxic products (radio toxic) that strengthen beam effect. Endogenous antioxidatic system (EAS) of an organism plays a significant role in detoxication of redundant quantity of FR formed in cells. Ionizing radiation influences negatively to high-grade functioning of basic EAS enzymes. Besides, during radiation injuries, the level of FR increases. In case of its exhaustion and lack insertion of natural antioxidants (bioantioxidants) to organism plays a therapeutic role. Thus, in our work we used saffron extract in experiments with the purpose of studying its effect on the activity of antioxidant enzymes at radiation influence. Determination of proteins has been carried out with Lowry method. In the result of carried-out researches, it has been detected fixed dynamics of activity change of antioxidant enzymes in various brain structures of white rats within x-ray irradiation at medium dose, and joint impact of x-ray radiation of saffron extract. Under exposure to X-ray irradiation of medium dose in some brain structures decreasing of catalase activity was revealed. Tendency towards decreasing is more developed on the 3th day of irradiation. As opposed to catalase activity GPO activity was increased. Insertion of saffron extract to experimental animals (for 21 days before irradiation) conducive to prevention the decreasing of catalase activity stabilizes GPO activity and exerts an effective influence. Thereby, bioantioxidants have significant role in the regulation of processes occurred in tissues and cells under the influence of extreme factors. Antioxidant protection system of organism carries out continuous protection of organism from toxic

  5. Soft x-ray scattering facility at the Advanced Light Source with real-time data processing and analysis.

    Science.gov (United States)

    Gann, E; Young, A T; Collins, B A; Yan, H; Nasiatka, J; Padmore, H A; Ade, H; Hexemer, A; Wang, C

    2012-04-01

    We present the development and characterization of a dedicated resonant soft x-ray scattering facility. Capable of operation over a wide energy range, the beamline and endstation are primarily used for scattering from soft matter systems around the carbon K-edge (∼285 eV). We describe the specialized design of the instrument and characteristics of the beamline. Operational characteristics of immediate interest to users such as polarization control, degree of higher harmonic spectral contamination, and detector noise are delineated. Of special interest is the development of a higher harmonic rejection system that improves the spectral purity of the x-ray beam. Special software and a user-friendly interface have been implemented to allow real-time data processing and preliminary data analysis simultaneous with data acquisition. © 2012 American Institute of Physics

  6. Processing and characterization of Sr{sub 2−x}VMoO{sub 6−δ} double perovskites

    Energy Technology Data Exchange (ETDEWEB)

    Weisentein, A.J., E-mail: a.weisenstein@gmail.com [Department of Mechanical and Industrial Engineering, Montana State University, Bozeman, MT 59717-3800 (United States); Childs, N., E-mail: nick.childs@msu.montana.edu [Department of Physics, Montana State University, Bozeman, MT 59717-3804 (United States); Amendola, R., E-mail: roberta.amendola@coe.montana.edu [Department of Chemical and Biological Engineering, Montana State University, Bozeman, MT 59717-3920 (United States); Driscoll, D., E-mail: davidrobertdriscoll@gmail.com [Department of Mechanical and Industrial Engineering, Montana State University, Bozeman, MT 59717-3800 (United States); Sofie, S.W., E-mail: ssofie@me.montana.edu [Department of Mechanical and Industrial Engineering, Montana State University, Bozeman, MT 59717-3800 (United States); Gannon, P., E-mail: pgannon@coe.montana.edu [Department of Chemical and Biological Engineering, Montana State University, Bozeman, MT 59717-3920 (United States); Smith, R., E-mail: smith@physics.montana.edu [Department of Physics, Montana State University, Bozeman, MT 59717-3804 (United States)

    2013-05-15

    In this study, the analysis and characterization of the processing and sintering of Sr{sub 2−x}VMoO{sub 6−δ} perovskites, where x = 0.0, 0.1 and 0.2, was investigated with application potential in high temperature fuel cell electrodes and electro-catalysts. Sr{sub 2−x}VMoO{sub 6−δ} substrates were sintered in a reducing (5%H{sub 2} 95%N{sub 2}) atmosphere at 1100 °C, 1200 °C, and 1300 °C. The X-ray diffraction patterns indicate that the double perovskite is the primary phase for Sr{sub 2−x}VMoO{sub 6−δ} pellets sintered at 1200 °C and 1300 °C for 20 h; however, these pellets show a secondary phase of SrMoO{sub 4−δ}. X-ray photoelectron spectroscopy revealed a deficiency of vanadium on the pellet surfaces, in which samples yielded surface vanadium concentrations of less than 5%. The vanadium inhomogeneity can be explained by the formation of the SrMoO{sub 4−δ} scheelite phase (ABO{sub 4}) due to oxygen exposure on the surface of the pellets, which indicates inward vanadium migration to the bulk, and was exhibited in redox cycling. Sr{sub 2−x}VMoO{sub 6−δ} pellets sintered at 1300 °C showed the lowest resistivity at both SOFC operating temperature (800 °C) and room temperature. The resistivity tests also show a semiconductor to metallic transition for all double perovskites, from heating up to 800 °C to cooling down to room temperature in a reducing atmosphere, related to the reduction of Mo{sup 6+} to Mo{sup 4+}. - Highlights: ► Primary Sr{sub 2−x}VMoO{sub 6−δ} phase only shown to form in excess of 1300 °C in reducing. ► Surface formation of secondary phase SrMoO{sub 4−δ} (Mo{sup 6+}) observed at RT in air. ► Surface vanadium deficiency induced by inward atomic diffusion. ► Semiconductor to metallic transition is related to the reduction of Mo{sup 6+} to Mo{sup 4+}.

  7. Effects of Block Length and Membrane Processing Conditions on the Morphology and Properties of Perfluorosulfonated Poly(arylene ether sulfone) Multiblock Copolymer Membranes for PEMFC.

    Science.gov (United States)

    Assumma, Luca; Nguyen, Huu-Dat; Iojoiu, Cristina; Lyonnard, Sandrine; Mercier, Régis; Espuche, Eliane

    2015-07-01

    Perfluorosulfonated poly(arylene ether sulfone) multiblock copolymers have been shown to be promising as proton exchange membranes. The commonly used approach for preparation of the membrane is solvent casting; the properties of the resulting membranes are very dependent on the membrane processing conditions. In this paper, we study the effects of block length, selectivity of the solvent, and thermal treatment on the membrane properties such as morphology, water uptake, and ionic conductivity. DiMethylSulfOxide (DMSO), and DiMethylAcetamide (DMAc) were selected as casting solvents based on the Flory-Huggins parameter calculated by inversion gas chromatography (IGC). It was found that the solvent selectivity has a mild impact on the mean size of the ionic domains and the expansion upon swelling, while it dramatically affects the supramolecular ordering of the blocks. The membranes cast from DMSO exhibit more interconnected ionic clusters yielding higher conductivities and water uptake as compared to membranes cast from DMAc. A 10-fold increase in proton conductivity was achieved after thermal annealing of membranes at 150 °C, and the ionomers with longer block lengths show conductivities similar to Nafion at 80 °C and low relative humidity (30%).

  8. Thermodynamic calculation and an experimental study of the combustion synthesis of (Mo{sub 1−x}Nb{sub x})Si{sub 2} (0 ⩽ x ⩽ 1)

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xiaohong, E-mail: matinbow@163.com; Lu, Qiong; Wu, Guangzhi; Shi, Jialing; Sun, Zhi

    2015-08-25

    Highlights: • (Mo{sub 1−x}Nb{sub x})Si{sub 2} alloys were synthesized by a simple and energy-saving process of SHS. • Theoretical adiabatic temperature of (Mo{sub 1−x}Nb{sub x})Si{sub 2} was calculated for the first time. • The variation of the actual temperature is consistent with theoretical temperature. - Abstract: The theoretical adiabatic temperature of (Mo{sub 1−x}Nb{sub x})Si{sub 2} (0 ⩽ x ⩽ 1) is calculated. The results indicate that the theoretical adiabatic temperature of (Mo{sub 1−x}Nb{sub x})Si{sub 2} increases with an increasing Nb content when (Mo{sub 1−x}Nb{sub x})Si{sub 2} is of a single-phase structure, but decreases with an increasing Nb content when (Mo{sub 1−x}Nb{sub x})Si{sub 2} is of a double-phase structure. All of the temperatures are higher than 1800 K, indicating that (Mo{sub 1−x}Nb{sub x})Si{sub 2} (0 ⩽ x ⩽ 1) can be prepared by the combustion synthesis method. In this work, (Mo{sub 1−x}Nb{sub x})Si{sub 2} (0 ⩽ x ⩽ 1) alloys are successfully synthesized by the combustion synthesis process from elemental powders of Mo, Nb, and Si. The highest combustion temperature and combustion product structure are studied. The results confirm that the variation of the experimental maximum combustion temperature of (Mo{sub 1−x}Nb{sub x})Si{sub 2} is consistent with that of the theoretical adiabatic temperature. The combustion products are non-equilibrium species, and a supersaturated solid solution of C11{sub b} type (Mo{sub 1−x}Nb{sub x})Si{sub 2} forms during combustion synthesis.

  9. Evaluating Sensory Processing in Fragile X Syndrome: Psychometric Analysis of the Brain Body Center Sensory Scales (BBCSS).

    Science.gov (United States)

    Kolacz, Jacek; Raspa, Melissa; Heilman, Keri J; Porges, Stephen W

    2018-06-01

    Individuals with fragile X syndrome (FXS), especially those co-diagnosed with autism spectrum disorder (ASD), face many sensory processing challenges. However, sensory processing measures informed by neurophysiology are lacking. This paper describes the development and psychometric properties of a parent/caregiver report, the Brain-Body Center Sensory Scales (BBCSS), based on Polyvagal Theory. Parents/guardians reported on 333 individuals with FXS, 41% with ASD features. Factor structure using a split-sample exploratory-confirmatory design conformed to neurophysiological predictions. Internal consistency, test-retest, and inter-rater reliability were good to excellent. BBCSS subscales converged with the Sensory Profile and Sensory Experiences Questionnaire. However, data also suggest that BBCSS subscales reflect unique features related to sensory processing. Individuals with FXS and ASD features displayed more sensory challenges on most subscales.

  10. X ray Production. Chapter 5

    Energy Technology Data Exchange (ETDEWEB)

    Nowotny, R. [Medical University of Vienna, Vienna (Austria)

    2014-09-15

    The differential absorption of X rays in tissues and organs, owing to their atomic composition, is the basis for the various imaging methods used in diagnostic radiology. The principles in the production of X rays have remained the same since their discovery. However, much refinement has gone into the design of X ray tubes to achieve the performance required for today’s radiological examinations. In this chapter, an outline of the principles of X ray production and a characterization of the radiation output of X ray tubes will be given. The basic processes producing X rays are dealt with in Section 1.4.

  11. Studies on molybdenum elution study in dowex 1x8 resin applied on purification process of fission 99Mo

    International Nuclear Information System (INIS)

    Damasceno, M.O.; Yamaura, M.; Santos, J.L. dos; Forbicini, C.A.L.G. de O.

    2013-01-01

    Molybdenum-99 is the most widely employed radioisotope in nuclear medicine, due to its decay product, Technetium-99, which is used in radio-pharmaceutical marking molecules for diagnostic examinations tumor dis-eases. Today Brazil imports 99 Mo from some countries, so the National Commission of Nuclear Energy (CNEN) is implementing a new research reactor RMB, currently in the conceptual design phase. The process of separation of fission 99 Mo begins with the dissolution of uranium targets after irradiation in reactor; the resulting solution goes through a series of chromatographic columns that allows a gradual decontamination of other components, yielding the 99 Mo with high radio-chemical and chemical purity for use in nuclear medicine as a generator of 99 mTc. This work is part of the RMB research project to separate and purify the fission 99 Mo by chromatographic columns from alkaline dissolution of LEU UAl x -Al targets. In the present study Mo removal by batch assays and glass column was investigated using anionic exchanger Dowex 1x8. Different salts and its concentration, cations and temperature were evaluated on elution of molybdenum and iodine (contaminant) retained on resin Dowex 1x8, aiming at their use in the process of separation and purification in chromatography columns on Brazilian project. Results showed high recovery of Mo and low-level contamination by iodine using NaHCO 3 hot solution. (author)

  12. Resonant x-ray Raman scattering from atoms and molecules

    International Nuclear Information System (INIS)

    Cowan, P.L.

    1992-01-01

    Inelastic x-ray scattering and elastic x-ray scattering are fundamentally related processes. When the x-ray photon energy is near the ionization threshold for an inner shell, the inelastic channel is dominated by resonant x-ray Raman scattering. Studies of this emission not only illuminate the resonant scattering process in general, they also point to new opportunities for spectral studies of electronic structure using x-rays. Atoms in the form of a free gas provide an ideal target for testing the current theoretical understanding of resonant x-ray Raman scattering. In addition, x-ray scattering from molecular gases demonstrates the effect of bonding symmetry on the polarization and angular distribution of the scattered x-rays. Comparisons of experimental data with theory demonstrate both the successes and limitations of simple, single-electron interpretations of the scattering process

  13. RLV/X-33 operations overview

    Science.gov (United States)

    Black, Stephen T.; Eshleman, Wally

    1997-01-01

    This paper describes the VentureStar™ SSTO RLV and X-33 operations concepts. Applications of advanced technologies, automated ground support systems, advanced aircraft and launch vehicle lessons learned have been integrated to develop a streamlined vehicle and mission processing concept necessary to meet the goals of a commercial SSTO RLV. These concepts will be validated by the X-33 flight test program where financial and technical risk mitigation are required. The X-33 flight test program totally demonstrates the vehicle performance, technology, and efficient ground operations at the lowest possible cost. The Skunk Work's test program approach and test site proximity to the production plant are keys. The X-33 integrated flight and ground test program incrementally expands the knowledge base of the overall system allowing minimum risk progression to the next flight test program milestone. Subsequent X-33 turnaround processing flows will be performed with an aircraft operations philosophy. The differences will be based on research and development, component reliability and flight test requirements.

  14. Maskless X-Ray Writing of Electrical Devices on a Superconducting Oxide with Nanometer Resolution and Online Process Monitoring.

    Science.gov (United States)

    Mino, Lorenzo; Bonino, Valentina; Agostino, Angelo; Prestipino, Carmelo; Borfecchia, Elisa; Lamberti, Carlo; Operti, Lorenza; Fretto, Matteo; De Leo, Natascia; Truccato, Marco

    2017-08-22

    X-ray nanofabrication has so far been usually limited to mask methods involving photoresist impression and subsequent etching. Herein we show that an innovative maskless X-ray nanopatterning approach allows writing electrical devices with nanometer feature size. In particular we fabricated a Josephson device on a Bi 2 Sr 2 CaCu 2 O 8+δ (Bi-2212) superconducting oxide micro-crystal by drawing two single lines of only 50 nm in width using a 17.4 keV synchrotron nano-beam. A precise control of the fabrication process was achieved by monitoring in situ the variations of the device electrical resistance during X-ray irradiation, thus finely tuning the irradiation time to drive the material into a non-superconducting state only in the irradiated regions, without significantly perturbing the crystal structure. Time-dependent finite element model simulations show that a possible microscopic origin of this effect can be related to the instantaneous temperature increase induced by the intense synchrotron picosecond X-ray pulses. These results prove that a conceptually new patterning method for oxide electrical devices, based on the local change of electrical properties, is actually possible with potential advantages in terms of heat dissipation, chemical contamination, miniaturization and high aspect ratio of the devices.

  15. Computer-Controlled Cylindrical Polishing Process for Development of Grazing Incidence Optics for Hard X-Ray Region

    Science.gov (United States)

    Khan, Gufran Sayeed; Gubarev, Mikhail; Speegle, Chet; Ramsey, Brian

    2010-01-01

    The presentation includes grazing incidence X-ray optics, motivation and challenges, mid spatial frequency generation in cylindrical polishing, design considerations for polishing lap, simulation studies and experimental results, future scope, and summary. Topics include current status of replication optics technology, cylindrical polishing process using large size polishing lap, non-conformance of polishin lap to the optics, development of software and polishing machine, deterministic prediction of polishing, polishing experiment under optimum conditions, and polishing experiment based on known error profile. Future plans include determination of non-uniformity in the polishing lap compliance, development of a polishing sequence based on a known error profile of the specimen, software for generating a mandrel polishing sequence, design an development of a flexible polishing lap, and computer controlled localized polishing process.

  16. Disk Disruptions and X-ray Intensity Excursions in Cyg X-2, LMC X-3 and Cyg X-3

    Science.gov (United States)

    Boyd, P. T.; Smale, A. P.

    2001-05-01

    The RXTE All Sky Monitor soft X-ray light curves of many X-ray binaries show long-term intensity variations (a.k.a "superorbital periodicities") that have been ascribed to precession of a warped, tilted accretion disk around the X-ray source. We have found that the excursion times between X-ray minima in Cyg X-2 can be characterized as a series of integer multiples of the 9.8 binary orbital period, (as opposed to the previously reported stable 77.7 day single periodicity, or a single modulation whose period changes slowly with time). While the data set is too short for a proper statistical analysis, it is clear that the length of any given intensity excursion cannot be used to predict the next (integer) excursion length in the series. In the black hole candidate system LMC X-3, the excursion times are shown to be related to each other by rational fractions. We find that the long term light curve of the unusual galactic X-ray jet source Cyg X-3 can also be described as a series of intensity excursions related to each other by integer multiples of a fundamental underlying clock. In the latter cases, the clock is apparently not related to the known binary periods. A unified physical model, involving both an inclined accretion disk and a fixed-probability disk disruption mechanism is presented, and compared with three-body scattering results. Each time the disk passes through the orbital plane it experiences a fixed probability P that it will disrupt. This model has testable predictions---the distribution of integers should resemble that of an atomic process with a characteristic half life. Further analysis can support or refute the model, and shed light on what system parameters effectively set the value of P.

  17. On the optimum processing conditions of Pb(Zr x Ti1-x )O3: revealing the mechanisms to increase the piezoelectric coefficients up to 1100 pm V-1

    Science.gov (United States)

    Zeibekis, M.; Vertsioti, G.; Stamopoulos, D.

    2016-03-01

    The ferroelectric compound family Pb(Zr x Ti1-x )O3 (PZT) is one of the most investigated and widely used piezoelectric materials. Optimization of the piezoelectric coefficients is observed for x ~ 0.52 (Pb(Zr0.52Ti0.48)O3) and is further promoted by the increase of grain size (GS). However, in some cases the piezoelectric properties of Pb(Zr0.52Ti0.48)O3 deteriorate upon processing due to the decrease of density, ρ, that is mostly ascribed to the appearance of byproduct phases. In the present study we discuss the influence of the processing conditions on the piezoelectric properties for polycrystalline Pb(Zr0.52Ti0.48)O3, specifically focusing on the sintering temperature, 1100 °C  ⩽  T sin  ⩽  1250 °C. To this end, we use atomic force microscopy (AFM), Archimedes’ method, x-ray diffraction (XRD) and a newly introduced local technique, based on a conventional optical microscope, which is further developed here to accommodate non-clamped specimens. The data obtained via this technique in the regime of relatively high electric fields evidence that the absolute piezoelectric coefficients, |d zi | (i  =  x, y) show a non-monotonic behavior with an unexpectedly high maximum value |d zi | ~ 1100 pm V-1 at T sin  =  1180 °C. These features are accompanied by a progressive increase of coercivity, reaching maximum value E C,i ~ 4.5-5.0 kV cm-1 (i  =  x, y) at T sin  =  1250 °C. To explain these findings, the |d zi | coefficients are compared with the microstructure and compositional information, coming from AFM, Archimedes’ method and XRD data. We conclude that the significantly high |d zi | values observed for samples prepared at T sin  =  1180 °C are motivated by the increase of mean GS, , while for T sin  >  1180 °C the decrease of density, ρ, ascribed to the appearance of byproduct phases, dominates and deteriorates |d zi |. These experimental results on |d zi |(T sin) are reliably

  18. Hall mobilities in GaN{sub x}As{sub 1-x}

    Energy Technology Data Exchange (ETDEWEB)

    Olea, Javier; Gonzalez-Diaz, German [Dpto. de Fisica Aplicada III, Facultad de Ciencias Fisicas, Universidad Complutense de Madrid, Madrid 28040 (Spain); Yu, Kin Man; Walukiewicz, Wladek [Materials Sciences Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720-8197 (United States)

    2010-07-15

    In this work we report a systematic study of the electron and hole mobilities of GaN{sub x}As{sub 1-x} alloys with different dopants (Zn, Te) and carrier concentrations (10{sup 17}-10{sup 19} cm{sup -3}). We found a very slight reduction of the hole mobility in p-GaN{sub x}As{sub 1-x} compared to p-GaAs, indicating that for small N contents ({proportional_to}1.6%) the valence band is not affected by the N incorporation. In a striking contrast, incorporation of even small amounts of N leads to an abrupt reduction of the electron mobility in n-GaN{sub x}As{sub 1-x}. We further show that the processes that limit the mobility in GaN{sub x}As{sub 1-x} can be explained by the band broadening and the random field scatterings. Considering these two scattering mechanisms we calculated the dependence of electron mobilities on electron concentration as well as on N composition in GaN{sub x}As{sub 1-x}. The calculations agree reasonably well with experiment data of maximum electron mobilities with alloy composition. (copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  19. Configuration Management for Wendelstein 7-X

    International Nuclear Information System (INIS)

    Brakel, R.; Eeten, P.v.; Hartmann, D.A.; Henkelmann, K.; Knauer, J.; Mueller, K.; Okkenga-Wolf, A.; Wenzel, U.

    2009-01-01

    A complex system like the large superconducting Wendelstein 7-X stellarator necessitates a dedicated organizational structure which assures permanent consistency between the requirements of its system specification and the performance attributes of all its components throughout its life time. This includes well-defined processes and centrally coordinated information structures. For this purposes the department Configuration Management (CM) has recently been established at W7-X. The detailed tasks of CM for W7-X are oriented along common CM standards and comprise configuration identification, change management, configuration status accounting and configuration verification. While the assembly of W7-X is proceeding some components are still under procurement or even under design. Thus design changes and non-conformances may have a direct impact on the assembly process. Highest priority has therefore been assigned to efficient control of change and non-conformance processes which might delay the assembly schedule.

  20. Magnetic behavior of NixFe(100-x) (65=<x=<100) nanowire arrays

    International Nuclear Information System (INIS)

    Navas, D.; Asenjo, A.; Jaafar, M.; Pirota, K.R.; Hernandez-Velez, M.; Sanz, R.; Lee, W.; Nielsch, K.; Batallan, F.; Vazquez, M.

    2005-01-01

    Arrays of magnetic nanowires with composition Ni x Fe (100-x) (65= 2 and 105nm lattice parameter of hexagonal symmetry, is achieved by self-ordering process, and characterized by SEM and AFM. Magnetic behavior of the arrays has been determined by VSM. Maximum coercivity of around 1.23kOe and reduced remanence (about 0.8 saturation magnetization) is observed for x=77, while minimum values are observed for x=100. Detailed AFM and MFM studies allow us to gain additional information of the filling degree of pores which can result in a distributed nanowires length that finally correlates with a deterioration of macroscopic magnetic behavior of the array

  1. A new manufacturing process to remove thrombogenic factors (II, VII, IX, X, and XI) from intravenous immunoglobulin gamma preparations.

    Science.gov (United States)

    Park, Dong Hwarn; Kang, Gil Bu; Kang, Dae Eun; Hong, Jeung Woon; Lee, Min Gyu; Kim, Ki Yong; Han, Jeung Whan

    2017-01-01

    Coagulation factors (II, VII, IX, X, and particularly XIa) remaining in high concentrations in intravenous immunoglobulin (IVIG) preparations can form thrombi, causing thromboembolic events, and in serious cases, result in death. Therefore, manufacturers of biological products must investigate the ability of their production processes to remove procoagulant activities. Previously, we were able to remove coagulation factors II, VII, IX, and X from our IVIG preparation through ethanol precipitation, but factor XIa, which plays an important role in thrombosis, remained in the intermediate products. Here, we used a chromatographic process using a new resin that binds with high capacity to IgG and removes procoagulant activities. The procoagulant activities were reduced to low levels as determined by the thrombin generation assay: 250 s, FXI/FXIa ELISA: <0.31 ng/mL. Even after spiking with FXIa at a concentration 32.5 times higher than the concentration in normal specimens, the procoagulant activities were below the detection limit (<0.31 ng/mL). These results demonstrate the ability of our manufacturing process to remove procoagulant activities to below the detection limit (except by NaPTT), suggesting a reduced risk of thromboembolic events that maybe potentially caused by our IVIG preparation. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  2. Photovoltaic performance of a Cd{sub 1−x}Mg{sub x}Te/CdS top-cell structure

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, Omar S. [Instituto de Energías Renovables, Universidad Nacional Autónoma de México, Temixco, Morelos 62580 (Mexico); Centro del Cambio Global y la Sustentabilidad en el Sureste, Villahermosa, Tabasco 86080 (Mexico); Regalado-Pérez, E.; Mathews, N.R. [Instituto de Energías Renovables, Universidad Nacional Autónoma de México, Temixco, Morelos 62580 (Mexico); Morales, Erik R. [División Académica de Ingeniería y Arquitectura, Universidad Juárez Autónoma de Tabasco, Cunduacán, Tabasco 86690 (Mexico); Reyes-Coronado, David [Unidad Académica Playa del Carmen, Universidad de Quintana Roo, Playa del Carmen, Quintana Roo 77710 (Mexico); Galvez, Geovanni Hernández [Centro del Cambio Global y la Sustentabilidad en el Sureste, Villahermosa, Tabasco 86080 (Mexico); Mathew, Xavier, E-mail: xm@ier.unam.mx [Instituto de Energías Renovables, Universidad Nacional Autónoma de México, Temixco, Morelos 62580 (Mexico)

    2015-05-01

    In this paper we report the progress in developing a wide band gap alloy material based on CdTe to use as the top-cell absorber in tandem solar cells. High photovoltaic performance for a Cd{sub 1−x}Mg{sub x}Te/CdS top-cell was achieved by tuning the composition of the Cd{sub 1−x}Mg{sub x}Te film, and optimizing the device processing. We have carried out studies on the effect of vapor chloride treatment of the Cd{sub 1−x}Mg{sub x}Te/CdS device and the thermal annealing of the Cu/Au contacts on the opto-electronic properties of the device. With improved contact processing and post deposition treatments, we were able to achieve 9.3% efficiency for a 1.6 eV band gap top-cell; Cd{sub 1−x}Mg{sub x}Te/CdS on conductive glass substrate. - Highlights: • Cd{sub 1−x}Mg{sub x}Te films obtained by co-evaporation of CdTe and Mg • Band gap of Cd{sub 1−x}Mg{sub x}Te can be easily tuned by verifying x. • Band gap of Cd{sub 1−x}Mg{sub x}Te is stable only for short annealing durations. • Obtained efficiency of a Cd{sub 1−x}Mg{sub x}Te based device with a band gap of 1.6 eV is 9.3%.

  3. Transforming spatial point processes into Poisson processes using random superposition

    DEFF Research Database (Denmark)

    Møller, Jesper; Berthelsen, Kasper Klitgaaard

    with a complementary spatial point process Y  to obtain a Poisson process X∪Y  with intensity function β. Underlying this is a bivariate spatial birth-death process (Xt,Yt) which converges towards the distribution of (X,Y). We study the joint distribution of X and Y, and their marginal and conditional distributions....... In particular, we introduce a fast and easy simulation procedure for Y conditional on X. This may be used for model checking: given a model for the Papangelou intensity of the original spatial point process, this model is used to generate the complementary process, and the resulting superposition is a Poisson...... process with intensity function β if and only if the true Papangelou intensity is used. Whether the superposition is actually such a Poisson process can easily be examined using well known results and fast simulation procedures for Poisson processes. We illustrate this approach to model checking...

  4. The effects of X-irradiation on the chondrogensis of mesenchymal cells

    International Nuclear Information System (INIS)

    Ha, Jong Ryeol

    2002-01-01

    It is well known that X-irradiation affects on maturing process of differentiated chondrocytes. Nevertheless, It has been remained elusively whether X-irradiation affects the process of differentiation of mesenchymal cells which differentiate into chondrocyte, fibroblast, or muscle cells. In this study, we examined the effect of X-irradiation (with 1 to 10 Gy) on chondrogenesis using mesenchymal cells of chick limb bud. Our results show that X-irradiation dose-dependently inhibited chondrogenesis. This result suggests that immature chondroblast-like mesenchymal cells are sensitive to X-irradiation, Moreover, X-irradiation affects not only maturing process of chondrocytes, but also inhibits the chondrogenesis. Taken together, we demonstrate that the whole process of differentiation of mature chondrocytes from mesenchymal cells is affected by X-irradiation and undifferentiated cells were more affected by X-irradiation than mature cells

  5. Mechanical alloying of Cu-xCr (x = 3, 5 and 8 wt.%) alloys

    International Nuclear Information System (INIS)

    Aguilar, C.; Ordonez, S.; Guzman, D.; Rojas, P.A.

    2010-01-01

    This work studies the structural evolution of Cu-xCr (x = 3, 5 and 8 wt.%) alloys processed by mechanical alloying using X-ray diffraction profiles, scanning microscopy and microhardness analysis. X-ray diffraction analysis using the modified Williamson-Hall and Warren-Averbach methods were used to determine structural properties, such as crystallite size, stacking fault probability and energy, dislocation density, lattice parameters and crystallite size distribution of metallic powder as a function of Cr amount and milling time. Lattice defects increase the Gibbs free energy and the Gibbs free energy curves shift upward, therefore the solubility limit change.

  6. Genetic and immunohistochemical analysis of HSPA5 in mouse and human retinas

    Science.gov (United States)

    Chintalapudi, Sumana R.; Wang, XiaoFei; Li, Huiling; Lau, Yin H. Chan; Williams, Robert W.; Jablonski, Monica M.

    2016-01-01

    Purpose Photoreceptor degenerative diseases are among the leading causes of vision loss. Although the causative genetic mutations are often known, mechanisms leading to photoreceptor degeneration remain poorly defined. We have previously demonstrated that the photoreceptor membrane-associated protein XAP-1 antigen is a product of the HSPA5 gene. In this study, we used systems genetic methods, statistical modeling, and immunostaining to identify and analyze candidate genes that modulate Hspa5 expression in the retina. Methods Quantitative trait locus (QTL) mapping was used to map the genomic region that regulates Hspa5 in the cross between C57BL/6J X DBA/2J mice (BXD) genetic reference panel. The stepwise refinement of candidate genes was based on expression QTL mapping, gene expression correlation analyses (direct and partial), and analysis of regional sequence variants. The subcellular localization of candidate proteins and HSPA5 in mouse and human retinas was evaluated by immunohistochemistry. Differences in the localization of extracellular HSPA5 were assessed between healthy human donor and atrophic age-related macular degeneration (AMD) donor eyes. Results In the eyes of healthy mice, extracellular HSPA5 was confined to the area around the cone photoreceptor outer segments. Mapping variation in Hspa5 mRNA expression levels in the retina revealed a statistically significant trans-acting expression QTL (eQTL) on Chromosome 2 (Chr 2) and a suggestive locus on Chr 15. Sulf2 on Chr 2 was the strongest candidate gene based on partial correlation analysis, Pearson correlation with Hspa5, expression levels in the retina, a missense variant in exon 14, and its reported function in the extracellular matrix and interphotoreceptor matrix. SULF2 is localized to the rod and cone photoreceptors in both human and mouse retinas. In human retinas with no pathology, extracellular HSPA5 was localized around many cones within the macular area. In contrast, fewer HSPA5

  7. PharmTeX: a LaTeX-Based Open-Source Platform for Automated Reporting Workflow.

    Science.gov (United States)

    Rasmussen, Christian Hove; Smith, Mike K; Ito, Kaori; Sundararajan, Vijayakumar; Magnusson, Mats O; Niclas Jonsson, E; Fostvedt, Luke; Burger, Paula; McFadyen, Lynn; Tensfeldt, Thomas G; Nicholas, Timothy

    2018-03-16

    Every year, the pharmaceutical industry generates a large number of scientific reports related to drug research, development, and regulatory submissions. Many of these reports are created using text processing tools such as Microsoft Word. Given the large number of figures, tables, references, and other elements, this is often a tedious task involving hours of copying and pasting and substantial efforts in quality control (QC). In the present article, we present the LaTeX-based open-source reporting platform, PharmTeX, a community-based effort to make reporting simple, reproducible, and user-friendly. The PharmTeX creators put a substantial effort into simplifying the sometimes complex elements of LaTeX into user-friendly functions that rely on advanced LaTeX and Perl code running in the background. Using this setup makes LaTeX much more accessible for users with no prior LaTeX experience. A software collection was compiled for users not wanting to manually install the required software components. The PharmTeX templates allow for inclusion of tables directly from mathematical software output as well and figures from several formats. Code listings can be included directly from source. No previous experience and only a few hours of training are required to start writing reports using PharmTeX. PharmTeX significantly reduces the time required for creating a scientific report fully compliant with regulatory and industry expectations. QC is made much simpler, since there is a direct link between analysis output and report input. PharmTeX makes available to report authors the strengths of LaTeX document processing without the need for extensive training. Graphical Abstract ᅟ.

  8. X-ray excited photoluminescence near the giant resonance in solid-solution Gd(1-x)Tb(x)OCl nanocrystals and their retention upon solvothermal topotactic transformation to Gd(1-x)Tb(x)F3.

    Science.gov (United States)

    Waetzig, Gregory R; Horrocks, Gregory A; Jude, Joshua W; Zuin, Lucia; Banerjee, Sarbajit

    2016-01-14

    Design rules for X-ray phosphors are much less established as compared to their optically stimulated counterparts owing to the absence of a detailed understanding of sensitization mechanisms, activation pathways and recombination channels upon high-energy excitation. Here, we demonstrate a pronounced modulation of the X-ray excited photoluminescence of Tb(3+) centers upon excitation in proximity to the giant resonance of the host Gd(3+) ions in solid-solution Gd1-xTbxOCl nanocrystals prepared by a non-hydrolytic cross-coupling method. The strong suppression of X-ray excited optical luminescence at the giant resonance suggests a change in mechanism from multiple exciton generation to single thermal exciton formation and Auger decay processes. The solid-solution Gd1-xTbxOCl nanocrystals are further topotactically transformed with retention of a nine-coordinated cation environment to solid-solution Gd1-xTbxF3 nanocrystals upon solvothermal treatment with XeF2. The metastable hexagonal phase of GdF3 can be stabilized at room temperature through this topotactic approach and is transformed subsequently to the orthorhombic phase. The fluoride nanocrystals indicate an analogous but blue-shifted modulation of the X-ray excited optical luminescence of the Tb(3+) centers upon X-ray excitation near the giant resonance of the host Gd(3+) ions.

  9. X-ray analysis in the steel industry

    International Nuclear Information System (INIS)

    Bourke, T.; Turner, K.

    1999-01-01

    Full text: The steel industry makes extensive use of X-ray analysis at all stages of the steelmaking process. XRF and XRD techniques, together with the associated techniques of electron probe microanalysis and electron microscopy are key tools for exploration and mine site and process development where detailed grade and mineralogical data is required. In production X-ray analysis is used to monitor and control: mine product grade (eg iron ore, coal and other raw materials), steel making production processes (eg iron ore sinter, incoming raw materials), waste products (eg coal watery refuse, slags) and final products (eg paint coatings, customer complaints). The demands put on X-ray analysis by the Steel Industry are severe. Iron ore mining and steelmaking is a continuous process, hence instrumentation has to be robust and reliable. In addition, with ever tightening environmental controls there is an increasing demand for trace heavy element analysis in both raw and waste materials. Copyright (1999) Australian X-ray Analytical Association Inc

  10. On the periodic orbits of the Third-order differential equation x ' ' '- x ' ' x'- x= F(x,x',x ' ')

    OpenAIRE

    Llibre, Jaume

    2013-01-01

    Agraïments: The second author is partially supported by CAPES/MECD-DGU 222/2010 Brazil and Spain In this paper we study the periodic orbits of the third-order differential equation x''' − µx'' + x' − µx = εF(x, x', x''), where ε is a small parameter and the function F is of class C2.

  11. High-intensity X-rays interaction with matter processes in plasmas, clusters, molecules and solids

    CERN Document Server

    Hau-Riege, Stefan P

    2012-01-01

    Filling the need for a book bridging the effect of matter on X-ray radiation and the interaction of x-rays with plasmas, this monograph provides comprehensive coverage of the topic. As such, it presents and explains such powerful new X-ray sources as X-ray free-electron lasers, as well as short pulse interactions with solids, clusters, molecules, and plasmas, and X-ray matter interactions as a diagnostic tool. Equally useful for researchers and practitioners working in the field.

  12. In-situ studies of the recrystallization process of CuInS2 thin films by energy dispersive X-ray diffraction

    International Nuclear Information System (INIS)

    Thomas, D.; Mainz, R.; Rodriguez-Alvarez, H.; Marsen, B.; Abou-Ras, D.; Klaus, M.; Genzel, Ch.; Schock, H.-W.

    2011-01-01

    Recrystallization processes during the sulfurization of CuInS 2 (CIS) thin films have been studied in-situ using energy dispersive X-ray diffraction (EDXRD) with synchrotron radiation. In order to observe the recrystallization isolated from other reactions occurring during film growth, Cu-poor, small grained CIS layers covered with CuS on top were heated in a vacuum chamber equipped with windows for synchrotron radiation in order to analyze the grain growth mechanism within the CIS layer. In-situ monitoring of the grain size based on diffraction line profile analysis of the CIS-112 reflection was utilized to interrupt the recrystallization process at different points. Ex-situ studies by electron backscatter diffraction (EBSD) and energy dispersive X-ray spectroscopy (EDX) performed on samples of intermediate recrystallization states reveal that during the heat treatment Cu and In interdiffuse inside the layer indicating the importance of the mobility of these two elements during CuInS 2 grain growth.

  13. Effect of ammonium hydroxide on preparation process of YBa2Cu3O7-x superconductor by sol gel method

    Directory of Open Access Journals (Sweden)

    H Arabi

    2006-09-01

    Full Text Available  In this paper the effect of ammonium hydroxide addition to the solution of metallic oxide on sol gel preparation process of YBCO is studied with differential thermal analysis, thermal graviometry and X-ray diffraction. Two samples with and without ammonium hydroxide. Ammonium hydroxide prevents both barium nitrate precipitate during the gel preparation and also unwanted reaction as well as increasing homogeneous product. After drying the gel, the samples heated up to 1050°C in DTA apparatus in order to find more accurate the type and the temperature of reaction during the preparation process. After the initial reactions in the samples, Y2Cu2O5 and 123 phases are created in the range of 780-840°C and then the 123 phase is strengthened at 900-950°C. As shown in X-ray data, 123 was the only phase after this range. In addition ammonium hydroxide support and increase the creation of 123 phase at lower temperature.

  14. Analysis of the charge collection process in solid state X-ray detectors

    Energy Technology Data Exchange (ETDEWEB)

    Kimmel, Nils

    2009-02-12

    Physics with X-rays spans from observing large scales in X-ray astronomy down to small scales in material structure analyses with synchrotron radiation. Both fields of research require imaging detectors featuring spectroscopic resolution for X-rays in an energy range of 0.1 keV to 20.0 keV. Originally driven by the need for an imaging spectrometer on ESA's X-ray astronomy satellite mission XMM-Newton, X-ray pnCCDs were developed at the semiconductor laboratory of the Max-Planck-Institute. The pnCCD is a pixel array detector made of silicon. It is sensitive over a wide band from near infrared- over optical- and UV-radiation up to X-rays. This thesis describes the dynamics of signal electrons from the moment after their generation until their collection in the potential minima of the pixel structure. Experimentally, a pinhole array was used to scan the pnCCD surface with high spatial resolution. Numerical simulations were used as a tool for the modeling of the electrical conditions inside the pnCCD. The results predicted by the simulations were compared with the measurements. Both, experiment and simulation, helped to establish a model for the signal charge dynamics in the energy range from 0.7 keV to 5.5 keV. More generally, the presented work has enhanced the understanding of the detector system on the basis of a physical model. The developed experimental and theoretical methods can be applied to any type of array detector which is based on the full depletion of a semiconductor substrate material. (orig.)

  15. Analysis of the charge collection process in solid state X-ray detectors

    International Nuclear Information System (INIS)

    Kimmel, Nils

    2009-01-01

    Physics with X-rays spans from observing large scales in X-ray astronomy down to small scales in material structure analyses with synchrotron radiation. Both fields of research require imaging detectors featuring spectroscopic resolution for X-rays in an energy range of 0.1 keV to 20.0 keV. Originally driven by the need for an imaging spectrometer on ESA's X-ray astronomy satellite mission XMM-Newton, X-ray pnCCDs were developed at the semiconductor laboratory of the Max-Planck-Institute. The pnCCD is a pixel array detector made of silicon. It is sensitive over a wide band from near infrared- over optical- and UV-radiation up to X-rays. This thesis describes the dynamics of signal electrons from the moment after their generation until their collection in the potential minima of the pixel structure. Experimentally, a pinhole array was used to scan the pnCCD surface with high spatial resolution. Numerical simulations were used as a tool for the modeling of the electrical conditions inside the pnCCD. The results predicted by the simulations were compared with the measurements. Both, experiment and simulation, helped to establish a model for the signal charge dynamics in the energy range from 0.7 keV to 5.5 keV. More generally, the presented work has enhanced the understanding of the detector system on the basis of a physical model. The developed experimental and theoretical methods can be applied to any type of array detector which is based on the full depletion of a semiconductor substrate material. (orig.)

  16. Thorium determination by x-ray fluorescence spectrometry in simulated thorex process solutions

    International Nuclear Information System (INIS)

    Yamaura, M.; Matsuda, H.T.

    1991-11-01

    The X-ray fluorescence method for thorium determination in aqueous and organic (TBP/n-dodecane) solutions is described. The thin film technique for sample preparation and a suitable internal standard had been used. The best conditions for Thorium determination had been established studying some parameters as analytical line, internal standard, filter paper, paper geometry, sample volume and measurement conditions. With the established conditions, thorium was concentration range of to 200 g Th/L and in organic solutions (2-63g Th/L) with 1,5% of precision. The accuracy of the proposed method was 3% in aqueous and organic phases. The detection limit was 1,2μg thorium for aqueous solutions and 1,4μg for organic solutions. Uranium, fission products, corrosion products and Thorex reagent components were studied as interfering elements in the thorium analysis. The matrix effect was also studied using the Thorex process simulated solutions. Finally, the method was applied to thorium determination in irradiated thorium solutions with satisfactory results. (author)

  17. Solar X-ray bursts

    International Nuclear Information System (INIS)

    Urnov, A.M.

    1980-01-01

    In the popular form the consideration is given to the modern state tasks and results of X-ray spectrometry of solar bursts. The operation of X-ray spectroheliograph is described. Results of spectral and polarization measurings of X-ray radiation of one powerful solar burst are presented. The conclusion has been drawn that in the process of burst development three characteristic stages may be distingwished: 1) the initial phase; just in this period processes which lead to observed consequences-electromagnetic and corpuscular radiation are born; 2) the impulse phase, or the phase of maximum, is characterised by sharp increase of radiation flux. During this phase the main energy content emanates and some volumes of plasma warm up to high temperatures; 3) the phase of burst damping, during which plasma cools and reverts to the initial condition

  18. X-ray image subtracting system

    International Nuclear Information System (INIS)

    Wesbey, W.H.; Keyes, G.S.; Georges, J.-P.J.

    1982-01-01

    An X-ray image subtracting system for making low contrast structures in the images more conspicuous is described. An X-ray source projects successive high and low energy X-ray beam pulses through a body and the resultant X-ray images are converted to optical images. Two image pick-up devices such as TV cameras that have synchronously operated shutters receive the alternate images and convert them to corresponding analog video signals. In some embodiments, the analog signals are converted to a matrix of digital pixel signals that are variously processed and subtracted and converted to signals for driving a TV monitor display and analog storage devices. In other embodiments the signals are processed and subtracted in analog form for display. The high and low energy pulses can follow each other immediately so good registration between subtracted images is obtainable even though the anatomy is in motion. The energy levels of the X-ray pulses are chosen to maximize the difference in attenuation between the anatomical structure which is to be subtracted out and that which remains. (author)

  19. Influence of preferred orientation of minerals in the mineralogical identification process by X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Amanda Luzia da; Oliveira, Arno H. de [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear; Fernandes, Maria Lourdes Souza, E-mail: lourdesfernandes@ufmg.b [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Inst. de GeoCiencias. Centro de Pesquisa Professor Manoel Teixeira da Costa

    2011-07-01

    The X-ray diffraction corresponds to one of the main techniques for characterization of microstructures in crystalline materials, widely used in the identification of minerals in samples of geological materials. Some minerals have a property called preferred orientation which corresponds to the orientation tendency of the crystals of ground minerals to orient themselves in certain directions according to a preferred crystallographic plane. This property affects the analysis by X-ray diffraction and this fact can generates erroneous results in the characterization. The purpose of this study is to identify the negative influence of the preferred orientation of a mineral in the generation of diffraction patterns obtained in the X-ray diffraction analysis. For this, a sample of muscovite, a mineral of mica group, was prepared by two different methods: the frontal method and the back loading method. In the analysis using the frontal method there was displacement of the XRD pattern in the abscissa axis, where it was observed changes in interplanar distance and angle 2{theta} values, which are essential information for characterization and identification of a mineral. In the analysis using the back loading method, the generated XRD pattern showed no displacement in the axis of abscissas and showed interplanar distance and angle 2{theta} values closer to the real values for the muscovite. The results showed that one can only make improvements to the process of sample preparation minimizing the effect of preferred orientation in the analysis. There is no need to change conditions of diffractometer measurements. (author)

  20. Influence of preferred orientation of minerals in the mineralogical identification process by X-ray diffraction

    International Nuclear Information System (INIS)

    Silva, Amanda Luzia da; Oliveira, Arno H. de; Fernandes, Maria Lourdes Souza

    2011-01-01

    The X-ray diffraction corresponds to one of the main techniques for characterization of microstructures in crystalline materials, widely used in the identification of minerals in samples of geological materials. Some minerals have a property called preferred orientation which corresponds to the orientation tendency of the crystals of ground minerals to orient themselves in certain directions according to a preferred crystallographic plane. This property affects the analysis by X-ray diffraction and this fact can generates erroneous results in the characterization. The purpose of this study is to identify the negative influence of the preferred orientation of a mineral in the generation of diffraction patterns obtained in the X-ray diffraction analysis. For this, a sample of muscovite, a mineral of mica group, was prepared by two different methods: the frontal method and the back loading method. In the analysis using the frontal method there was displacement of the XRD pattern in the abscissa axis, where it was observed changes in interplanar distance and angle 2θ values, which are essential information for characterization and identification of a mineral. In the analysis using the back loading method, the generated XRD pattern showed no displacement in the axis of abscissas and showed interplanar distance and angle 2θ values closer to the real values for the muscovite. The results showed that one can only make improvements to the process of sample preparation minimizing the effect of preferred orientation in the analysis. There is no need to change conditions of diffractometer measurements. (author)

  1. Different X-ray spectral evolution for black hole X-ray binaries in dual tracks of radio-X-ray correlation

    International Nuclear Information System (INIS)

    Cao, Xiao-Feng; Wu, Qingwen; Dong, Ai-Jun

    2014-01-01

    Recently, an 'outlier' track of radio-X-ray correlation was found, which is much steeper than the former universal correlation, where dual tracks were speculated to be triggered by different accretion processes. In this work, we test this issue by exploring hard X-ray spectral evolution in four black-hole X-ray binaries with multiple, quasi-simultaneous radio and X-ray observations. First, we find that hard X-ray photon indices, Γ, are negatively and positively correlated with X-ray fluxes when the X-ray flux, F 3-9 keV , is below and above a critical flux, F X, crit , which are consistent with predictions of the advection-dominated accretion flow and the disk-corona model, respectively. Second, and most importantly, we find that the radio-X-ray correlations are also clearly different when the X-ray fluxes are higher and lower than the critical flux as defined by X-ray spectral evolution. The data points with F 3-9 keV ≳ F X, crit have a steeper radio-X-ray correlation (F X ∝F R b and b ∼ 1.1-1.4), which roughly forms the ''outlier'' track. However, the data points with anti-correlation of Γ – F 3-9 keV either stay in the universal track with b ∼ 0.61 or stay in the transition track (from the universal to 'outlier' tracks or vice versa). Therefore, our results support that the universal and ''outlier'' tracks of radio-X-ray correlations are regulated by radiatively inefficient and radiatively efficient accretion model, respectively.

  2. Amorphous SiO {sub x} nanowires grown on silicon (100) substrates via rapid thermal process of nanodiamond films

    Energy Technology Data Exchange (ETDEWEB)

    Liang Xingbo [State Key Lab of Silicon Materials, Zhejiang University, Hangzhou 310027 (China); Wang Lei [State Key Lab of Silicon Materials, Zhejiang University, Hangzhou 310027 (China); Yang Deren [State Key Lab of Silicon Materials, Zhejiang University, Hangzhou 310027 (China)]. E-mail: mseyang@zju.edu.cn

    2006-05-01

    Rapid thermal process (RTP) has been carried out on the deposited nanocrystalline diamond (NCD) films. The RTP treatments performed at 800 and 1200 deg. C have been shown to exert prominent influence on the morphology and structure of the NCD films. The loss of material at grain boundaries has been observed at both 800 and 1200 deg. C RTP treatments. Large-scale amorphous SiO {sub x} nanowires with diameters of 30-50 nm and length up to 10 {mu}m were synthesized after RTP treatment at 1200 deg. C for 60 s. The synthesized nanowires were characterized in detail by scanning electron microscopy, transmission electron microscopy, selected area electron diffraction and energy-dispersed X-ray spectrometry analysis. A possible growth mechanism has been proposed to explain the observed phenomenon.

  3. Process of constructing a lightweight x-ray flight mirror assembly

    Science.gov (United States)

    McClelland, Ryan S.; Biskach, Michael P.; Chan, Kai-Wing; Espina, Rebecca A.; Hohl, Bruce R.; Saha, Timo T.; Zhang, William W.

    2014-07-01

    Lightweight and high resolution optics are needed for future space-based x-ray telescopes to achieve advances in highenergy astrophysics. NASA's Next Generation X-ray Optics (NGXO) project has made significant progress towards building such optics, both in terms of maturing the technology for spaceflight readiness and improving the angular resolution. Technology Development Modules (TDMs) holding three pairs of mirrors have been regularly and repeatedly integrated and tested both for optical performance and mechanical strength. X-ray test results have been improved over the past year from 10.3 arc-seconds Half Power Diameter (HPD) to 8.3 arc-seconds HPD. A vibration test has been completed to NASA standard verification levels showing the optics can survive launch and pointing towards improvements in strengthening the modules through redundant bonds. A Finite Element Analysis (FEA) study was completed which shows the mirror distortion caused by bonding is insensitive to the number of bonds. Next generation TDMs, which will demonstrate a lightweight structure and mount additional pairs of mirrors, have been designed and fabricated. The light weight of the module structure is achieved through the use of E-60 Beryllium Oxide metal matrix composite material. As the angular resolution of the development modules has improved, gravity distortion during horizontal x-ray testing has become a limiting factor. To address this issue, a facility capable of testing in the vertical orientation has been designed and planned. Test boring at the construction site suggest standard caisson construction methods can be utilized to install a subterranean vertical vacuum pipe. This facility will also allow for the testing of kinematically mounted mirror segments, which greatly reduces the effect of bonding displacements. A development platform demonstrating the feasibility of kinematically mounting mirror segments has been designed, fabricated, and successfully tested.

  4. Nonrelativistic quantum X-ray physics

    CERN Document Server

    Hau-Riege, Stefan P

    2015-01-01

    Providing a solid theoretical background in photon-matter interaction, Nonrelativistic Quantum X-Ray Physics enables readers to understand experiments performed at XFEL-facilities and x-ray synchrotrons. As a result, after reading this book, scientists and students will be able to outline and perform calculations of some important x-ray-matter interaction processes. Key features of the contents are that the scope reaches beyond the dipole approximation when necessary and that it includes short-pulse interactions. To aid the reader in this transition, some relevant examples are discussed in detail, while non-relativistic quantum electrodynamics help readers to obtain an in-depth understanding of the formalisms and processes. The text presupposes a basic (undergraduate-level) understanding of mechanics, electrodynamics, and quantum mechanics. However, more specialized concepts in these fields are introduced and the reader is directed to appropriate references. While primarily benefiting users of x-ray light-sou...

  5. Studies of Plasma Instabilities Excited by Ground-Based High Power HF (Heating) Facilities and of X and Gamma Ray Emission in Runaway Breakdown Processes

    National Research Council Canada - National Science Library

    Gurevich, Aleksander V

    2006-01-01

    .... The runaway breakdown process in inhomogeneous thunderstorm electric field; 5. X-ray emission in different gases due to runaway breakdown phenomena in a laboratory cyclotron installation; 6. An influence of combined effects of runaway breakdown and cosmic rays on lightning processes in thunderstorm atmosphere.

  6. Optimized fabrication protocols of microfluidic devices for X-ray analysis

    KAUST Repository

    Catalano, Rossella

    2014-07-01

    Microfluidics combined with X-ray scattering techniques allows probing conformational changes or assembly processes of biological materials. Our aim was to develop a highly X-ray transparent microfluidic cell for detecting small variations of X-ray scattering involved in such processes. We describe the fabrication of a polyimide microfluidic device based on a simple, reliable and inexpensive lamination process. The implemented microstructured features result in windows with optimized X-ray transmission. The microfluidic device was characterized by X-ray microbeam scattering at the ID13 beamline of the European Synchrotron Radiation Facility. © 2014 Elsevier B.V. All rights reserved.

  7. X-ray data booklet. Revision

    Energy Technology Data Exchange (ETDEWEB)

    Vaughan, D. (ed.)

    1986-04-01

    A compilation of data is presented. Included are properties of the elements, electron binding energies, characteristic x-ray energies, fluorescence yields for K and L shells, Auger energies, energy levels for hydrogen-, helium-, and neonlike ions, scattering factors and mass absorption coefficients, and transmission bands of selected filters. Also included are selected reprints on scattering processes, x-ray sources, optics, x-ray detectors, and synchrotron radiation facilities. (WRF)

  8. Astronomy and astrophysics of galactic X-ray binaries: from the nature of the X-ray sources to the physics of accretion processes

    International Nuclear Information System (INIS)

    Rodriguez, Jerome

    2010-01-01

    In this HDR (Accreditation to supervise research) report, the author proposes an overview of his research works in the field of accretion of X-ray binaries. After a presentation of X-ray binaries, neutron stars and black holes, micro-quasars, and of the main issues regarding X-ray binaries, the author presents and comments his activities in X-ray astronomy and gamma-ray astronomy (the INTEGRAL observatory, the discovery of new sources of X and gamma radiation, studies of new sources at different wavelengths). The second part addresses the understanding of source accretion: phenomenological studies in astronomy, relationships between accretion and ejection. The third part presents and comments several studies of the physics of phenomena related to matter accretion and ejection. (author) [fr

  9. On the oxidation of the three-dimensional aromatics [B(12)X(12)](2-) (X=F, Cl, Br, I).

    Science.gov (United States)

    Boeré, René T; Derendorf, Janis; Jenne, Carsten; Kacprzak, Sylwia; Kessler, Mathias; Riebau, Rainer; Riedel, Sebastian; Roemmele, Tracey L; Rühle, Monika; Scherer, Harald; Vent-Schmidt, Thomas; Warneke, Jonas; Weber, Stefan

    2014-04-07

    The perhalogenated closo-dodecaborate dianions [B12 X12 ](2-) (X=H, F, Cl, Br, I) are three-dimensional counterparts to the two-dimensional aromatics C6 X6 (X=H, F, Cl, Br, I). Whereas oxidation of the parent compounds [B12 H12 ](2-) and benzene does not lead to isolable radicals, the perhalogenated analogues can be oxidized by chemical or electrochemical methods to give stable radicals. The chemical oxidation of the closo-dodecaborate dianions [B12 X12 ](2-) with the strong oxidizer AsF5 in liquid sulfur dioxide (lSO2 ) yielded the corresponding radical anions [B12 X12 ](⋅-) (X=F, Cl, Br). The presence of radical ions was proven by EPR and UV/Vis spectroscopy and supported by quantum chemical calculations. Use of an excess amount of the oxidizing agent allowed the synthesis of the neutral perhalogenated hypercloso-boranes B12 X12 (X=Cl, Br). These compounds were characterized by single-crystal X-ray diffraction of dark blue B12 Cl12 and [Na(SO2 )6 ][B12 Br12 ]⋅B12 Br12 . Sublimation of the crude reaction products that contained B12 X12 (X=Cl, Br) resulted in pure dark blue B12 Cl12 or decomposition to red B9 Br9 , respectively. The energetics of the oxidation processes in the gas phase were calculated by DFT methods at the PBE0/def2-TZVPP level of theory. They revealed the trend of increasing ionization potentials of the [B12 X12 ](2-) dianions by going from fluorine to bromine as halogen substituent. The oxidation of all [B12 X12 ](2-) dianions was also studied in the gas phase by mass spectrometry in an ion trap. The electrochemical oxidation of the closo-dodecaborate dianions [B12 X12 ](2-) (X=F, Cl, Br, I) by cyclic and Osteryoung square-wave voltammetry in liquid sulfur dioxide or acetonitrile showed very good agreement with quantum chemical calculations in the gas phase. For [B12 X12 ](2-) (X=F, Cl, Br) the first and second oxidation processes are detected. Whereas the first process is quasi-reversible (with oxidation potentials in the range between +1

  10. Interpretation of chest radiographs with a high-resolution (2,000 x 2,000 x 12 bit) display

    International Nuclear Information System (INIS)

    Cox, G.G.

    1989-01-01

    This paper presents an evaluation of high-resolution (2K x 2Kx 12 bit) display for interpretation of chest radiographs. Three radiologists chose a total of 165 chest radiographs to ensure representation of nine signs: apical pleural scarring, chronic obstructive pulmonary disease, interstitial processes, atelectasis, pneumothorax, hilar mass, pleural effusion, pneumonia, and nodules. Each chest film was digitized to 4Kx 4Kx 12 bit and averaged to 2Kx 2Kx 12 bit and printed on a laser film printer. The 2K x 2K x 12-bit images were displayed and interactively windowed on a 2K x 2K x 12-bit high-resolution gray-scale cathode ray tube display. Six radiologists, none of whom participated in the case selection process, then interpreted a mixture of the screen film chest radiographs, the laser printed 2K chest radiographs, and the high resolution displayed 2K images

  11. Development of direct observation aparatus of coal carbonization process by x-ray computerized tomography method

    International Nuclear Information System (INIS)

    Sakawa, Mitsuhiro; Shiraishi, Katsuhiko; Sakurai, Yoshihisa; Shimomura, Yasuto

    1987-01-01

    Coke production by chamber ovens has a long history and efforts are being continued to make the manufacturing process efficient and to preserve the environment. In this production by this method, however, it is hardly possible to obtain direct information during coal carbonization. Since the elements that compose coal and coke are carbon, hydrogen, oxygen, etc. and are similar to those of the human body, authors has developed a coke oven that permits the direct observation of the coal carbonization process using a soft X-ray computerized tomography (CT) apparatus used in medical treatment. The following phenomena can be observed as images by the coke oven for the CT method : 1) Changes in the bulk density of charge coal (including the difference in the water content), 2) Width of the plastic layer and movement of the plastic layer in the coke oven chamber, 3) Expansion and shrinkage of the charge in the coke oven chamber, 4) Initiation and growth of cracks. (author)

  12. PFGE analysis of DNA double-strand breaks and DNA repair process in human osteosarcoma cells irradiated by X-ray

    International Nuclear Information System (INIS)

    Cao Jianping; Majima, H.; Yamaguchi, C.

    2000-01-01

    Objective: To study the induction of DNA double-strand breaks (DSBs) in human osteosarcoma cells irradiated by X-ray, the DNA DSBs repair process and the tumour cell radiosensitivity. Methods: Two cell lines of human osteosarcoma, Rho0 and 143. B were used. Initial DNA damage of DSBs by X-ray irradiation was measured using clamped homogeneous electrical field (CHEF) electrophoresis. Results: X-ray-induced DNA DSBs of human osteosarcoma cells after CHEF-electrophoresis increased linearly with the irradiation dose between 0 and 50 Gy. The repair of DNA DSBs in human osteosarcoma cells increased with the post-irradiation incubation time. In contrast to 14.3B cell line at the same dose point, much more DNA DSBs were induced in Rho0 cell line after X-ray irradiation. Conclusion: CHEF pulsed-field gel electrophoresis (PEGE) is a sensitive method for the determination of radiation-induced DNA DSBs in high molecular weight DNA of human osteosarcoma cells. Radiation-induced DNA DSBs of osteosarcoma increase with the dose in a linear manner. After incubation, both Rho0 cell line and 143. B cell line can repair the DNA DSBs. Between two cell lines of human osteosarcoma, Rho0 and 143.B, Rho0 cell line is more sensitive to ionizing radiation than 143.B line

  13. Information extracting and processing with diffraction enhanced imaging of X-ray

    International Nuclear Information System (INIS)

    Chen Bo; Chinese Academy of Science, Beijing; Chen Chunchong; Jiang Fan; Chen Jie; Ming Hai; Shu Hang; Zhu Peiping; Wang Junyue; Yuan Qingxi; Wu Ziyu

    2006-01-01

    X-ray imaging at high energies has been used for many years in many fields. Conventional X-ray imaging is based on the different absorption within a sample. It is difficult to distinguish different tissues of a biological sample because of their small difference in absorption. The authors use the diffraction enhanced imaging (DEI) method. The authors took images of absorption, extinction, scattering and refractivity. In the end, the authors presented pictures of high resolution with all these information combined. (authors)

  14. X-ray emission as a potential hazard during ultrashort pulse laser material processing

    Science.gov (United States)

    Legall, Herbert; Schwanke, Christoph; Pentzien, Simone; Dittmar, Günter; Bonse, Jörn; Krüger, Jörg

    2018-06-01

    In laser machining with ultrashort laser pulses unwanted X-ray radiation in the keV range can be generated when a critical laser intensity is exceeded. Even if the emitted X-ray dose per pulse is low, high laser repetition rates can lead to an accumulation of X-ray doses beyond exposure safety limits. For 925 fs pulse duration at a center wavelength of 1030 nm, the X-ray emission was investigated up to an intensity of 2.6 × 1014 W/cm2. The experiments were performed in air with a thin disk laser at a repetition rate of 400 kHz. X-ray spectra and doses were measured for various planar target materials covering a wide range of the periodic table from aluminum to tungsten. Without radiation shielding, the measured radiation doses at this high repetition rate clearly exceed the regulatory limits. Estimations for an adequate radiation shielding are provided.

  15. A Multi-Scale Flood Monitoring System Based on Fully Automatic MODIS and TerraSAR-X Processing Chains

    Directory of Open Access Journals (Sweden)

    Enrico Stein

    2013-10-01

    Full Text Available A two-component fully automated flood monitoring system is described and evaluated. This is a result of combining two individual flood services that are currently under development at DLR’s (German Aerospace Center Center for Satellite based Crisis Information (ZKI to rapidly support disaster management activities. A first-phase monitoring component of the system systematically detects potential flood events on a continental scale using daily-acquired medium spatial resolution optical data from the Moderate Resolution Imaging Spectroradiometer (MODIS. A threshold set controls the activation of the second-phase crisis component of the system, which derives flood information at higher spatial detail using a Synthetic Aperture Radar (SAR based satellite mission (TerraSAR-X. The proposed activation procedure finds use in the identification of flood situations in different spatial resolutions and in the time-critical and on demand programming of SAR satellite acquisitions at an early stage of an evolving flood situation. The automated processing chains of the MODIS (MFS and the TerraSAR-X Flood Service (TFS include data pre-processing, the computation and adaptation of global auxiliary data, thematic classification, and the subsequent dissemination of flood maps using an interactive web-client. The system is operationally demonstrated and evaluated via the monitoring two recent flood events in Russia 2013 and Albania/Montenegro 2013.

  16. Epitaxial lateral overgrowth of Ga{sub x}In{sub 1-x}P toward direct Ga{sub x}In{sub 1-x}P/Si heterojunction

    Energy Technology Data Exchange (ETDEWEB)

    Omanakuttan, Giriprasanth; Stergiakis, Stamoulis; Sychugov, Ilya; Lourdudoss, Sebastian; Sun, Yan-Ting [Department of Materials and Nano Physics, School of Information and Communication Technology, Royal Institute of Technology-KTH, Kista (Sweden); Sahgal, Abhishek [Department of Materials and Nano Physics, School of Information and Communication Technology, Royal Institute of Technology-KTH, Kista (Sweden); Department of Physics, Indian Institute of Technology Delhi, New Delhi (India)

    2017-03-15

    The growth of GaInP by hydride vapor phase epitaxy (HVPE) was studied on planar GaAs, patterned GaAs for epitaxial lateral overgrowth (ELOG), and InP/Si seed templates for corrugated epitaxial lateral overgrowth (CELOG). First results on the growth of direct GaInP/Si heterojunction by CELOG is presented. The properties of Ga{sub x}In{sub (1-x)}P layer and their dependence on the process parameters were investigated by X-ray diffraction, including reciprocal lattice mapping (XRD-RLM), scanning electron microscopy equipped with energy-dispersive X-ray spectroscopy (SEM-EDS), photoluminescence (PL), and Raman spectroscopy. The fluctuation of Ga composition in the Ga{sub x}In{sub (1-x)}P layer was observed on planar substrate, and the strain caused by the composition variation is retained until relaxation occurs. Fully relaxed GaInP layers were obtained by ELOG and CELOG. Raman spectroscopy reveals that there is a certain amount of ordering in all of the layers except those grown at high temperatures. Orientation dependent Ga incorporation in the CELOG, but not in the ELOG Ga{sub x}In{sub (1-x)}P layer, and Si incorporation in the vicinity of direct Ga{sub x}In{sub (1-x)}P/Si heterojunction from CELOG are observed in the SEM-EDS analyses. The high optical quality of direct GaInP/Si heterojunction was observed by cross-sectional micro-PL mapping and the defect reduction effect of CELOG was revealed by high PL intensity in GaInP above Si. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  17. Synthesis and characterization of nano-crystalline Ce1-xGd xO2-x/2 (x = 0-0.30) solid solutions

    DEFF Research Database (Denmark)

    Jadhav, L. D.; Chourashiya, M. G.; Jamale, A. P.

    2010-01-01

    glycine-nitrate process (GNP) has been presented. Evolution of structural and morphological properties of nano-powders as a function of heat treatment has also been studied. The prepared samples were characterized using TG-DTA, FT-IR, Raman spectroscopy, XRD, SEM, etc. In addition, the effect of Gd......In recent years, doped ceria is an established and promising candidate as solid electrolyte for intermediate temperature solid oxide fuel cell (IT-SOFC). In this investigation, synthesis and characterizations of nano-crystalline Gd doped ceria, (Ce1-xGdxO2-x/2, where x = 0-0.3), prepared using...... of sintered samples was observed to hinder with an increase in Gd content....

  18. Sensory processing in autism spectrum disorders and Fragile X syndrome—From the clinic to animal models

    Science.gov (United States)

    Sinclair, D.; Oranje, B.; Razak, K.A.; Siegel, S.J.; Schmid, S.

    2017-01-01

    Brains are constantly flooded with sensory information that needs to be filtered at the pre-attentional level and integrated into endogenous activity in order to allow for detection of salient information and an appropriate behavioral response. People with Autism Spectrum Disorder (ASD) or Fragile X Syndrome (FXS) are often over- or under-reactive to stimulation, leading to a wide range of behavioral symptoms. This altered sensitivity may be caused by disrupted sensory processing, signal integration and/or gating, and is often being neglected. Here, we review translational experimental approaches that are used to investigate sensory processing in humans with ASD and FXS, and in relevant rodent models. This includes electroencephalographic measurement of event related potentials, neural oscillations and mismatch negativity, as well as habituation and pre-pulse inhibition of startle. We outline robust evidence of disrupted sensory processing in individuals with ASD and FXS, and in respective animal models, focusing on the auditory sensory domain. Animal models provide an excellent opportunity to examine common mechanisms of sensory pathophysiology in order to develop therapeutics. PMID:27235081

  19. Reversibility of U → F processes in X or UV irradiated KCl: H- systems

    International Nuclear Information System (INIS)

    Bressiani, Ana Helena A.

    1979-01-01

    Potassium Chloride crystals, pure, additively colored or hydrogenated have been exposed to X and UV radiations for correlation studies' of formation processes of defects. In hydrogenated samples, these irradiations are responsible-for a direct U→F centers conversion with the simultaneous creation of H 2 molecules besides the intrinsic formation of F/hole centers. After prolonged irradiation, F aggregate centers react with H 2 molecules forming U center pairs. As the two U centers have independent electronic transitions they add up, increasing the maximum height of the U band after F→U reversed reation. The saturation levels of defects produced by these two types of radiation are different because UV light also excites F centers while producing them. This effect is responsible by the F center aggregation and the inversion F→U decreasing the U→F efficiency. Crystals with F and U centers under F light also show F→U inversion but with higher efficiency than when under UV light. This F→U process gives back 90% of the initial U center concentration. This same F→U process was observed but at smaller rate of formation if samples containing U, F and F aggregates are left in the dark for prolonged periods of time. The same reactions take place namely H 2 molecules annihilation F aggregates. (author)

  20. Crystallization of Zr2PdxCu1-x and Zr2NixCu1-x Metallic Glass

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Min [Iowa State Univ., Ames, IA (United States)

    2008-01-01

    One interesting aspect of rretallic glasses is the numerous instances of the deviation of the phase selection from the amorphous state to thermodynamically stable phases during the crystallization process. Their devitrification pathways allow us to study the relationship between the original amorphous structure and their crystalline counter parts. Among the various factors of phase selections, size and electronic effects have been most extensively studied. Elucidating the phase selection process of a glassy alloy will be helpful to fill in the puzzle of the changes from disordered to ordered structures. In this thesis, Two model Zr2PdxCu1-x and Zr2NixCu1-x (x = 0, 0.25, 0.5, 0.75 and 1) glassy systems were investigated since: (1) All of the samples can be made into a homogenous metallic glass; (2) The atomic radii differ from Pd to Cu is by 11%, while Ni has nearly the identical atomic size compare to Cu. Moreover, Pd and Ni differ by only one valence electron from Cu. Thus, these systems are ideal to test the idea of the effects of electronic structure and size factors; (3) The small number of components in these pseudo binary systems readily lend themselves to theoretical modeling. Using high temperature X-ray diffraction (HTXRD) and thermal analysis, topological, size, electronic, bond and chemical distribution factors on crystallization selections in Zr2PdxCu1-x and Zr2NixCu1-x metallic glass have been explored. All Zr2PdxCu1-x compositions share the same Cu11b phase with different pathways of meta-stable, icosahedral quasicrystalline phase (i-phase), and C16 phase formations. The quasicrystal phase formation is topologically related to the increasing icosahedral short range order (SRO) with Pd content in Zr2PdxCu1-x system. Meta-stable C16 phase is competitive with

  1. Nanofocusing refractive X-ray lenses

    Energy Technology Data Exchange (ETDEWEB)

    Boye, Pit

    2010-02-05

    This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is required. This is achieved in refractive lenses by moving to a compact lens design where several single lenses are stacked behind each other. The, so-called nanofocusing refractive lenses (NFLs) have a parabolic cylindrical shape with lateral structure sizes in the micrometer range. NFLs are produced by using micro-machining techniques. These micro-fabrication processes and technologies are introduced. The results of the optimization and the final fabrication process for silicon lenses are presented. Subsequently, two experiments that are exemplary for the use of NFLs, are introduced. The rst one employs a high-resolution scanning fluorescence mapping of a geological sample, and the second one is a coherent x-ray diffraction imaging (CXDI) experiment. CXDI is able to reconstruct the illuminated object from recorded coherent diffraction patterns. In a scanning mode, referred to as ptychography, this method is even able to reconstruct the illumination and the object simultaneously. Especially the reconstructed illumination and the possibility of computed propagation of the wave field along the

  2. Nanofocusing refractive X-ray lenses

    International Nuclear Information System (INIS)

    Boye, Pit

    2010-01-01

    This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is required. This is achieved in refractive lenses by moving to a compact lens design where several single lenses are stacked behind each other. The, so-called nanofocusing refractive lenses (NFLs) have a parabolic cylindrical shape with lateral structure sizes in the micrometer range. NFLs are produced by using micro-machining techniques. These micro-fabrication processes and technologies are introduced. The results of the optimization and the final fabrication process for silicon lenses are presented. Subsequently, two experiments that are exemplary for the use of NFLs, are introduced. The rst one employs a high-resolution scanning fluorescence mapping of a geological sample, and the second one is a coherent x-ray diffraction imaging (CXDI) experiment. CXDI is able to reconstruct the illuminated object from recorded coherent diffraction patterns. In a scanning mode, referred to as ptychography, this method is even able to reconstruct the illumination and the object simultaneously. Especially the reconstructed illumination and the possibility of computed propagation of the wave field along the

  3. Einstein pictures the x-ray sky

    International Nuclear Information System (INIS)

    Hartline, B.K.

    1979-01-01

    The second High Energy Astronomy Observatory (HEAO-2, Einstein) is revolutionizing x-ray astronomy just as its namesake revolutionized physics. Earlier x-ray observatories, including HEAO-1, were designed to scan the sky for x-ray emitters. With Einstein, the challenge has shifted from discovering x-ray sources to understanding the processes producing the x-rays. But having 500 times the sensitivity of previous detectors, Einstein makes more than its share of discoveries, too. For example, it sees distant quasars and clusters of galaxies that can barely be detected by the largest optical telescopes

  4. Energy resolution and throughput of a new real time digital pulse processing system for x-ray and gamma ray semiconductor detectors

    International Nuclear Information System (INIS)

    Abbene, L; Gerardi, G; Raso, G; Brai, M; Principato, F; Basile, S

    2013-01-01

    New generation spectroscopy systems have advanced towards digital pulse processing (DPP) approaches. DPP systems, based on direct digitizing and processing of detector signals, have recently been favoured over analog pulse processing electronics, ensuring higher flexibility, stability, lower dead time, higher throughput and better spectroscopic performance. In this work, we present the performance of a new real time DPP system for X-ray and gamma ray semiconductor detectors. The system is based on a commercial digitizer equipped with a custom DPP firmware, developed by our group, for on-line pulse shape and height analysis. X-ray and gamma ray spectra measurements with cadmium telluride (CdTe) and germanium (Ge) detectors, coupled to resistive-feedback preamplifiers, highlight the excellent performance of the system both at low and high rate environments (up to 800 kcps). A comparison with a conventional analog electronics showed the better high-rate capabilities of the digital approach, in terms of energy resolution and throughput. These results make the proposed DPP system a very attractive tool for both laboratory research and for the development of advanced detection systems for high-rate-resolution spectroscopic imaging, recently proposed in diagnostic medicine, industrial imaging and security screening

  5. A direct test of the Weinberg-Salam model based on the investigation of p-odd asymmetries in the processes l-++N → l-++X

    International Nuclear Information System (INIS)

    Bilen'ky, S.M.; Motz, G.

    1978-01-01

    In the framework of the Weinberg-Salam model the p-odd asymmetries Asub(+-) of the processes l -+ +N → l -+ +X with polarized leptons are shown to be related to the inclusive cross sections νsub(μ)(anti vsub(μ))+N → μ - (μ + )+X on an isoscalar target. It is shown that measurements of both Asub(-) and Asub(+) would permit one to test the Weinberg-Salam theory without dynamical assumptions

  6. Phase and Texture of Solution-Processed Copper Phthalocyanine Thin Films Investigated by Two-Dimensional Grazing Incidence X-Ray Diffraction

    Directory of Open Access Journals (Sweden)

    Lulu Deng

    2011-07-01

    Full Text Available The phase and texture of a newly developed solution-processed copper phthalocyanine (CuPc thin film have been investigated by two-dimensional grazing incidence X-ray diffraction. The results show that it has β phase crystalline structure, with crystallinity greater than 80%. The average size of the crystallites is found to be about 24 nm. There are two different arrangements of crystallites, with one dominating the diffraction pattern. Both of them have preferred orientation along the thin film normal. Based on the similarities to the vacuum deposited CuPc thin films, the new solution processing method is verified to offer a good alternative to vacuum process, for the fabrication of low cost small molecule based organic photovoltaics.

  7. A comparison of density of Insight and Ektaspeed plus dental x-ray films using automatic and manual processing

    International Nuclear Information System (INIS)

    Yoon, Suk Ja

    2001-01-01

    To compare the film density of Insight dental X-ray film (Eastman Kodak Co., Rochester, NY, USA) with that of Ektaspeed Plus film (Eastman Kodak) under manual and automatic processing conditions. Insight and wedge on the film under the three different exposure times. The exposed films were processed by both manual and automatic ways. The Base plus fog density and the optical density and the optical density made by exposing step wedge were calculated using a digital densitometer (model 07-443, Victoreen Inc, Cleveland, Ohio, USA). The optical densities of the Insight and Ektaspeed film versus thickness of aluminum wedge at the same exposure time were plotted on the graphs. Statistical analyses were applied for comparing the optical densities of the two films. The film density of both Insight films and Ektaspeed Plus films under automatic processing condition was significantly higher over the manual processing. The film density of Insight over Ektaspeed Plus film. To take the full advantage of reducing exposure time, Insight film should be processed automatically

  8. Effects of Benzalkonium Chloride, Proxel LV, P3 Hypochloran, Triton X-100 and DOWFAX 63N10 on anaerobic digestion processes

    DEFF Research Database (Denmark)

    Flores, German Antonio Enriquez; Fotidis, Ioannis; Karakashev, Dimitar Borisov

    2015-01-01

    In this study, the individual and synergistic toxicity of the following xenobiotics: Benzalkonium Chloride (BKC), Proxel LV (PRX), P3 Hypochloran (HPC), Triton X-100 (TRX), and DOWFAX 63N10 (DWF), on anaerobic digestion (AD) process, was assessed. The experiments were performed in batch and conti......In this study, the individual and synergistic toxicity of the following xenobiotics: Benzalkonium Chloride (BKC), Proxel LV (PRX), P3 Hypochloran (HPC), Triton X-100 (TRX), and DOWFAX 63N10 (DWF), on anaerobic digestion (AD) process, was assessed. The experiments were performed in batch...... and continuous (up-flow anaerobic sludge blanket, UASB) reactors with biochemical-industrial wastewater, as substrate. In batch experiments, half-maximal inhibitory concentrations (IC50) for the tested xenobiotics were found to be 13.1, 1003, 311.5 and 24.3 mg L1 for BKC, PRX, DWF and TRX, respectively while HPC...... observed from the batch reactors. Oppositely, TRX showed no inhibition in continuous mode, while inhibition was detected at batch mode....

  9. Guides for intraoral x-rays

    International Nuclear Information System (INIS)

    Ogunsunlade, O.A.

    1988-01-01

    An h-shaped exterior guide for use in combination with a SNAP-A-RAY film holder for accurately aligning a beam from an X-ray cone with an X-ray film during the process of taking intraoral periapical dental X-rays of the maxillary and mandibular teeth is described comprising: a first guide arm laterally and detachably connectable through a housing means; a traverse arm extending from the midpoint of the first guide arm and parallel to the X-ray film; and a second guide arm extending perpendicularly from an end of the traverse arm toward a plane of the X-ray film and in parallel relation up to an end point of the first guide arm

  10. Using 13X, LiX, and LiPdAgX zeolites for CO_2 capture from post-combustion flue gas

    International Nuclear Information System (INIS)

    Chen, S.J.; Zhu, M.; Fu, Y.; Huang, Y.X.; Tao, Z.C.; Li, W.L.

    2017-01-01

    Highlights: • We synthesized a novel adsorbent named LiPdAgX zeolite. • CCS was proposed from microstructure, selectivity and separation factor of zeolite. • The static and flowing adsorption using CO_2/N_2 mixture on X zeolites were studied. • LiPdAgX zeolite required less energy for regeneration compared to 13X and MEA. • LiPdAgX zeolite can effectively capture CO_2 from post-combustion flue gas. - Abstract: This work investigates the application of X zeolites for capturing CO_2 from post-combustion flue gas. LiX and LiPdAgX zeolites were prepared by an ion-exchange method using 13X zeolite. X-ray diffraction analysis showed that all samples exhibited characteristic peaks of X zeolites, where the peak intensities increased in the order: LiPdAgX > LiX > 13X. The enhanced intensity of the diffraction peaks can increase the activity of the X zeolites and improve their adsorption performance. Scanning electron microscopy imaging showed that the intergranular pore canals of LiPdAgX zeolite were more concentrated. Pore structure analysis indicated that addition of Li"+ to the 13X zeolite enhanced the specific surface areas and pore volumes of the zeolites. Among the 13X, LiX, and LiPdAgX zeolites, LiPdAgX showed the highest CO_2/N_2selectivity, where the difference in the CO_2 adsorption capacity was due to differences in the number of adsorption sites and thermal conductivities of the X zeolites. The CO_2 breakthrough time increased in succession for the 13X, LiX, and LiPdAgX zeolites. The CO_2/N_2 separation factor of the LiPdAgX zeolite was twice that of the 13X zeolite at a CO_2 concentration of 20 vol.%. The temperature variations during the adsorption process were used to determine the regeneration energy and adsorption capacity of the X zeolites. LiPdAgX zeolite required less energy for regeneration than 13X zeolite and MEA. After regeneration, the separation factor of LiPdAgX zeolite remained at 6.38 for 20 vol.% CO_2 in the flue gas. Therefore, LiPdAgX

  11. Immunocytochemical analysis of P2X2 in rat circumvallate taste buds.

    Science.gov (United States)

    Yang, Ruibiao; Montoya, Alana; Bond, Amanda; Walton, Jenna; Kinnamon, John C

    2012-05-23

    Our laboratory has shown that classical synapses and synaptic proteins are associated with Type III cells. Yet it is generally accepted that Type II cells transduce bitter, sweet and umami stimuli. No classical synapses, however, have been found associated with Type II cells. Recent studies indicate that the ionotropic purinergic receptors P2X2/P2X3 are present in rodent taste buds. Taste nerve processes express the ionotropic purinergic receptors (P2X2/P2X3). P2X2/P2X3(Dbl-/-) mice are not responsive to sweet, umami and bitter stimuli, and it has been proposed that ATP acts as a neurotransmitter in taste buds. The goal of the present study is to learn more about the nature of purinergic contacts in rat circumvallate taste buds by examining immunoreactivity to antisera directed against the purinergic receptor P2X2. P2X2-like immunoreactivity is present in intragemmal nerve processes in rat circumvallate taste buds. Intense immunoreactivity can also be seen in the subgemmal nerve plexuses located below the basal lamina. The P2X2 immunoreactive nerve processes also display syntaxin-1-LIR. The immunoreactive nerves are in close contact with the IP(3)R3-LIR Type II cells and syntaxin-1-LIR and/or 5-HT-LIR Type III cells. Taste cell synapses are observed only from Type III taste cells onto P2X2-LIR nerve processes. Unusually large, "atypical" mitochondria in the Type II taste cells are found only at close appositions with P2X2-LIR nerve processes. P2X2 immunogold particles are concentrated at the membranes of nerve processes at close appositions with taste cells. Based on our immunofluorescence and immunoelectron microscopical studies we believe that both perigemmal and most all intragemmal nerve processes display P2X2-LIR. Moreover, colloidal gold immunoelectron microscopy indicates that P2X2-LIR in nerve processes is concentrated at sites of close apposition with Type II cells. This supports the hypothesis that ATP may be a key neurotransmitter in taste transduction

  12. The X'tal cube PET detector with a monolithic crystal processed by the 3D sub-surface laser engraving technique: Performance comparison with glued crystal elements

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Eiji, E-mail: rush@nirs.go.jp [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Hirano, Yoshiyuki; Tashima, Hideaki; Inadama, Naoko; Nishikido, Fumihiko [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Moriya, Takahiro; Omura, Tomohide; Watanabe, Mitsuo [Hamamatsu Photonics K.K., 5000 Hirakuchi, Hamakita-ku, Hamamatsu, Shizuoka 434-8601 (Japan); Murayama, Hideo; Yamaya, Taiga [Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan)

    2013-09-21

    The X'tal cube is a depth-of-interaction (DOI)-PET detector which is aimed at obtaining isotropic resolution by effective readout of scintillation photons from six sides of the crystal block. The X'tal cube is composed of a 3D crystal block with isotropic segments. Each face of the 3D crystal block is covered with a 4×4 array of multi-pixel photon counters (MPPCs). Previously, in order to fabricate the 3D crystal block efficiently and precisely, we applied a sub-surface laser engraving technique to a monolithic crystal block instead of gluing segmented small crystals. A dense arrangement of multiple micro-cracks carved by the laser beam works efficiently as a scattering wall for the scintillation photons. The X'tal cube with the laser-processed block showed excellent performance with respect to crystal identification and energy resolution. In this work, for characteristics comparison between the laser-processed block and the conventional segmented array block, we made the laser-processed block and two types of segmented array blocks, one with air gaps and the other with glued segmented small crystals. All crystal blocks had 3D grids of 2 mm pitch. The 4×4 MPPC arrays were optically coupled to each surface of the crystal block. When performance was evaluated using a uniform irradiation of 511 keV, we found that the X'tal cubes with the laser-processed block could easily achieve 2 mm{sup 3} uniform crystal identification. Also, the average energy resolution of each 3D grid was 11.1±0.7%. On the other hand, the glued segmented array block had a pinched distribution and crystals could not be separated clearly. The segmented array block with air gaps had satisfactory crystal identification performance; however, the laser-processed block had higher crystal identification performance. Also, the energy resolution of the laser-processed block was better than for the segmented array blocks. In summary, we found the laser-processed X'tal cube had

  13. Visible-light photocatalytic decolorization of reactive brilliant red X-3B on Cu{sub 2}O/crosslinked-chitosan nanocomposites prepared via one step process

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Chunhua [College of Resource and Environmental Science, Wuhan University, Wuhan 430072 (China); Key Laboratory of Optoelectronic Chemical Materials and Devices of Ministry of Education, College of Chemical and Environmental Engineering, Jianghan University, Wuhan 430056 (China); Xiao, Ling, E-mail: xiaoling9119@yahoo.cn [College of Resource and Environmental Science, Wuhan University, Wuhan 430072 (China); Liu, Li; Zhu, Huayue [College of Resource and Environmental Science, Wuhan University, Wuhan 430072 (China); Chen, Chunhua; Gao, Lin [Key Laboratory of Optoelectronic Chemical Materials and Devices of Ministry of Education, College of Chemical and Environmental Engineering, Jianghan University, Wuhan 430056 (China)

    2013-04-15

    Cu{sub 2}O/crosslinked-chitosan nanocomposites (Cu{sub 2}O/CS NCs) were in situ prepared via a simple one-step liquid phase precipitation–reduction process and characterized by XRD, FT-IR, SEM, TEM, BET, XPS and UV–vis/DRS. The characterization results showed that Cu{sub 2}O/CS NCs were almost similar spherical or ellipsoidal and the surface was rough and porous because Cu{sub 2}O particle was wrapped in chitosan. The chitosan layer was especially favorable for improving the adsorption ability of dye and molecular oxygen and restraining the recombination of electrons–holes pair. The visible-light photocatalytic decolorization behavior on Cu{sub 2}O/CS NCs was evaluated using reactive brilliant red X-3B (X-3B) as a model pollutant. The influences of various experimental factors on X-3B decolorization were investigated. It was found that the photocatalytic decolorization process on Cu{sub 2}O/CS NCs followed apparent pseudo-first-order kinetics model. The dye X-3B could be decolorized more efficiently in acidic media than in alkaline media. Cu{sub 2}O/CS NCs exhibited enhanced visible-light photocatalytic activity compared with other photocatalysts reported before under similar experimental conditions.

  14. High speed imaging of dynamic processes with a switched source x-ray CT system

    International Nuclear Information System (INIS)

    Thompson, William M; Lionheart, William R B; Morton, Edward J; Cunningham, Mike; Luggar, Russell D

    2015-01-01

    Conventional x-ray computed tomography (CT) scanners are limited in their scanning speed by the mechanical constraints of their rotating gantries and as such do not provide the necessary temporal resolution for imaging of fast-moving dynamic processes, such as moving fluid flows. The Real Time Tomography (RTT) system is a family of fast cone beam CT scanners which instead use multiple fixed discrete sources and complete rings of detectors in an offset geometry. We demonstrate the potential of this system for use in the imaging of such high speed dynamic processes and give results using simulated and real experimental data. The unusual scanning geometry results in some challenges in image reconstruction, which are overcome using algebraic iterative reconstruction techniques and explicit regularisation. Through the use of a simple temporal regularisation term and by optimising the source firing pattern, we show that temporal resolution of the system may be increased at the expense of spatial resolution, which may be advantageous in some situations. Results are given showing temporal resolution of approximately 500 µs with simulated data and 3 ms with real experimental data. (paper)

  15. Compton Reflection in AGN with Simbol-X

    Science.gov (United States)

    Beckmann, V.; Courvoisier, T. J.-L.; Gehrels, N.; Lubiński, P.; Malzac, J.; Petrucci, P. O.; Shrader, C. R.; Soldi, S.

    2009-05-01

    AGN exhibit complex hard X-ray spectra. Our current understanding is that the emission is dominated by inverse Compton processes which take place in the corona above the accretion disk, and that absorption and reflection in a distant absorber play a major role. These processes can be directly observed through the shape of the continuum, the Compton reflection hump around 30 keV, and the iron fluorescence line at 6.4 keV. We demonstrate the capabilities of Simbol-X to constrain complex models for cases like MCG-05-23-016, NGC 4151, NGC 2110, and NGC 4051 in short (10 ksec) observations. We compare the simulations with recent observations on these sources by INTEGRAL, Swift and Suzaku. Constraining reflection models for AGN with Simbol-X will help us to get a clear view of the processes and geometry near to the central engine in AGN, and will give insight to which sources are responsible for the Cosmic X-ray background at energies >20 keV.

  16. Transforming Our Understanding of the X-ray Universe: The Imaging X-ray Polarimeter Explorer (IXPE)

    Science.gov (United States)

    Weisskopf, Martin C.; Bellazzini, Ronaldo; Costa, Enrico; Matt, Giorgio; Marshall, Herman; ODell, Stephen L.; Pavlov, George; Ramsey, Brian; Romani, Roger

    2014-01-01

    Accurate X-ray polarimetry can provide unique information on high-energy-astrophysical processes and sources. As there have been no meaningful X-ray polarization measurements of cosmic sources since our pioneering work in the 1970's, the time is ripe to explore this new parameter space in X-ray astronomy. To accomplish this requires a well-calibrated and well understood system that-particularly for an Explorer mission-has technical, cost, and schedule credibility. The system that we shall present satisfies these conditions, being based upon completely calibrated imaging- and polarization-sensitive detectors and proven X-ray-telescope technology.

  17. API 5L X80 PSL2 pipes manufactured by ERW process: TenarisConfab and USIMINAS development; Tubos API 5L X80 PSL2 processados por ERW: desenvolvimento TenarisConfab-Usiminas

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Ronaldo C.; Roza, Juliana E.; Kojima, Sergio S. [TenarisConfab, Pindamonhangaba, SP (Brazil); Miranda, Lucio S.; Turani, Leonardo O. [USIMINAS, Ipatinga, MG (Brazil)

    2005-07-01

    The utilization of high strength steels can decrease, both, installation and operation costs of a new pipeline, since the increase of mechanical resistance can reduce the pipe wall thickness and, consequently, the weight of the pipe. For this purpose, the manufacture of electric resistance welding (ERW) pipes is recent, and it comes as an opportunity for gas pipelines, mainly onshore projects. As a function of their larger productivity, ERW pipes are more economically attractive than those produced by seamless and SAW processes. TenarisConfab and USIMINAS, through studies and investments in manufacturing processes, have been working to increase their skills, in order to supply ERW pipes in API 5L X80 PSL2 steel. The steel elaborated by USIMINAS is low C, high Mn, Nb, V and Ti microalloyed, and with additions of Cr and Mo, aiming to produce hot rolled coils with acicular microstructure, achieved as a combination between its chemical composition and higher cooling rates after hot rolling. The results in {phi}18''(457 mm) x 0,469''(11,91 mm) pipes are presented in this article. High toughness values reached at very low temperatures suggest that ERW API 5L X80 PSL2 pipes developed by TenarisConfab and USIMINAS may be an excellent option of choice for onshore projects that request pipes in diameters up to 20''(508 mm) and thickness up to 0,500'' (12,7 mm). (author)

  18. Selective Spatial Processing Deficits in an At-Risk Subgroup of the Fragile X Premutation

    Science.gov (United States)

    Hocking, Darren R.; Kogan, Cary S.; Cornish, Kim M.

    2012-01-01

    Until a decade ago, it was assumed that males with the fragile X premutation were unaffected by any cognitive phenotype. Here we examined the extent to which CGG repeat toxicity extends to visuospatial functioning in male fragile X premutation carriers who are asymptomatic for a late-onset neurodegenerative disorder, fragile X-associated…

  19. Effect of Different Thermomechanical Processes on the Microstructure, Texture, and Mechanical Properties of API 5L X70 Steel

    Science.gov (United States)

    Masoumi, Mohammad; Echeverri, Edwan Anderson Ariza; Silva, Cleiton Carvalho; Béreš, Miloslav; de Abreu, Hamilton Ferreira Gomes

    2018-03-01

    A commercial API 5L X70 steel plate was subjected to different thermomechanical processes to propose a novel thermomechanical rolling path to achieve improved mechanical properties. Scanning electron microscopy, electron backscatter diffraction, and x-ray texture analysis were employed for microstructural characterization. The results showed that strain-free recrystallized {001} ferrite grains that developed at higher rolling temperature could not meet the American Petroleum Institute (API) requirements. Also, refined and work-hardened grains that have formed in the intercritical region with high stored energy do not provide suitable tensile properties. However, fine martensite-austenite constituents dispersed in ferrite matrix with grains having predominantly {111} and {110} orientations parallel to the normal direction that developed under isothermal rolling at 850 °C provided an outstanding combination of tensile strength and ductility.

  20. Functional magnetic resonance imaging in awake transgenic fragile X rats: evidence of dysregulation in reward processing in the mesolimbic/habenular neural circuit.

    Science.gov (United States)

    Kenkel, W M; Yee, J R; Moore, K; Madularu, D; Kulkarni, P; Gamber, K; Nedelman, M; Ferris, C F

    2016-03-22

    Anxiety and social deficits, often involving communication impairment, are fundamental clinical features of fragile X syndrome. There is growing evidence that dysregulation in reward processing is a contributing factor to the social deficits observed in many psychiatric disorders. Hence, we hypothesized that transgenic fragile X mental retardation 1 gene (fmr1) KO (FX) rats would display alterations in reward processing. To this end, awake control and FX rats were imaged for changes in blood oxygen level dependent (BOLD) signal intensity in response to the odor of almond, a stimulus to elicit the innate reward response. Subjects were 'odor naive' to this evolutionarily conserved stimulus. The resulting changes in brain activity were registered to a three-dimensional segmented, annotated rat atlas delineating 171 brain regions. Both wild-type (WT) and FX rats showed robust brain activation to a rewarding almond odor, though FX rats showed an altered temporal pattern and tended to have a higher number of voxels with negative BOLD signal change from baseline. This pattern of greater negative BOLD was especially apparent in the Papez circuit, critical to emotional processing and the mesolimbic/habenular reward circuit. WT rats showed greater positive BOLD response in the supramammillary area, whereas FX rats showed greater positive BOLD response in the dorsal lateral striatum, and greater negative BOLD response in the retrosplenial cortices, the core of the accumbens and the lateral preoptic area. When tested in a freely behaving odor-investigation paradigm, FX rats failed to show the preference for almond odor which typifies WT rats. However, FX rats showed investigation profiles similar to WT when presented with social odors. These data speak to an altered processing of this highly salient novel odor in the FX phenotype and lend further support to the notion that altered reward systems in the brain may contribute to fragile X syndrome symptomology.

  1. X-ray imaging system

    International Nuclear Information System (INIS)

    Houston, J.M.

    1980-01-01

    A novel, high-speed apparatus for use in X-ray computerised tomography is described in detail. It consists of a semi-circular array of X-ray sources, collimators and an ion chamber array for detection of the X-rays. The X-ray sources may be pulsed in salvos such that the corresponding detectors in the array are only illuminated by one source. The use of computer controlled salvos speeds up the image processing by at least a factor of two. The ion chamber array is designed to have a constant detection efficiency for varying angles of X-ray incidence. A detailed description of the detector construction and suggested gaseous fillings are given. It is claimed that the present tomographic system allows fast and accurate imaging of internal body organs and is insensitive to the blurring effects which motion of these organs tends to produce. (UK)

  2. Fabrication of polycrystalline diamond refractive X-ray lens by femtosecond laser processing

    Energy Technology Data Exchange (ETDEWEB)

    Kononenko, T.V.; Ralchenko, V.G.; Ashkinazi, E.E.; Konov, V.I. [General Physics Institute of Russian Academy of Sciences, Moscow (Russian Federation); National Research Nuclear University ' ' MEPhI' ' , Moscow (Russian Federation); Polikarpov, M.; Ershov, P. [Immanuel Kant Baltic Federal University, Functional Nanomaterials, Kaliningrad (Russian Federation); Kuznetsov, S.; Yunkin, V. [Institute of Microelectronics Technology RAS, Chernogolovka, Moscow region (Russian Federation); Snigireva, I. [European Synchrotron Radiation Facility, Grenoble (France)

    2016-03-15

    X-ray planar compound refractive lenses were fabricated from a polycrystalline diamond plate grown by chemical vapor deposition, by precise through cutting with femtosecond laser pulses. The lens geometry and the surface morphology were investigated with optical and scanning electron microscopy, while the material structure modification was analyzed by Raman spectroscopy. The results of the preliminary lens test at 9.25-keV X-rays are presented. (orig.)

  3. Fabrication of polycrystalline diamond refractive X-ray lens by femtosecond laser processing

    International Nuclear Information System (INIS)

    Kononenko, T.V.; Ralchenko, V.G.; Ashkinazi, E.E.; Konov, V.I.; Polikarpov, M.; Ershov, P.; Kuznetsov, S.; Yunkin, V.; Snigireva, I.

    2016-01-01

    X-ray planar compound refractive lenses were fabricated from a polycrystalline diamond plate grown by chemical vapor deposition, by precise through cutting with femtosecond laser pulses. The lens geometry and the surface morphology were investigated with optical and scanning electron microscopy, while the material structure modification was analyzed by Raman spectroscopy. The results of the preliminary lens test at 9.25-keV X-rays are presented. (orig.)

  4. The DNA sequence of the human X chromosome

    Science.gov (United States)

    Ross, Mark T.; Grafham, Darren V.; Coffey, Alison J.; Scherer, Steven; McLay, Kirsten; Muzny, Donna; Platzer, Matthias; Howell, Gareth R.; Burrows, Christine; Bird, Christine P.; Frankish, Adam; Lovell, Frances L.; Howe, Kevin L.; Ashurst, Jennifer L.; Fulton, Robert S.; Sudbrak, Ralf; Wen, Gaiping; Jones, Matthew C.; Hurles, Matthew E.; Andrews, T. Daniel; Scott, Carol E.; Searle, Stephen; Ramser, Juliane; Whittaker, Adam; Deadman, Rebecca; Carter, Nigel P.; Hunt, Sarah E.; Chen, Rui; Cree, Andrew; Gunaratne, Preethi; Havlak, Paul; Hodgson, Anne; Metzker, Michael L.; Richards, Stephen; Scott, Graham; Steffen, David; Sodergren, Erica; Wheeler, David A.; Worley, Kim C.; Ainscough, Rachael; Ambrose, Kerrie D.; Ansari-Lari, M. Ali; Aradhya, Swaroop; Ashwell, Robert I. S.; Babbage, Anne K.; Bagguley, Claire L.; Ballabio, Andrea; Banerjee, Ruby; Barker, Gary E.; Barlow, Karen F.; Barrett, Ian P.; Bates, Karen N.; Beare, David M.; Beasley, Helen; Beasley, Oliver; Beck, Alfred; Bethel, Graeme; Blechschmidt, Karin; Brady, Nicola; Bray-Allen, Sarah; Bridgeman, Anne M.; Brown, Andrew J.; Brown, Mary J.; Bonnin, David; Bruford, Elspeth A.; Buhay, Christian; Burch, Paula; Burford, Deborah; Burgess, Joanne; Burrill, Wayne; Burton, John; Bye, Jackie M.; Carder, Carol; Carrel, Laura; Chako, Joseph; Chapman, Joanne C.; Chavez, Dean; Chen, Ellson; Chen, Guan; Chen, Yuan; Chen, Zhijian; Chinault, Craig; Ciccodicola, Alfredo; Clark, Sue Y.; Clarke, Graham; Clee, Chris M.; Clegg, Sheila; Clerc-Blankenburg, Kerstin; Clifford, Karen; Cobley, Vicky; Cole, Charlotte G.; Conquer, Jen S.; Corby, Nicole; Connor, Richard E.; David, Robert; Davies, Joy; Davis, Clay; Davis, John; Delgado, Oliver; DeShazo, Denise; Dhami, Pawandeep; Ding, Yan; Dinh, Huyen; Dodsworth, Steve; Draper, Heather; Dugan-Rocha, Shannon; Dunham, Andrew; Dunn, Matthew; Durbin, K. James; Dutta, Ireena; Eades, Tamsin; Ellwood, Matthew; Emery-Cohen, Alexandra; Errington, Helen; Evans, Kathryn L.; Faulkner, Louisa; Francis, Fiona; Frankland, John; Fraser, Audrey E.; Galgoczy, Petra; Gilbert, James; Gill, Rachel; Glöckner, Gernot; Gregory, Simon G.; Gribble, Susan; Griffiths, Coline; Grocock, Russell; Gu, Yanghong; Gwilliam, Rhian; Hamilton, Cerissa; Hart, Elizabeth A.; Hawes, Alicia; Heath, Paul D.; Heitmann, Katja; Hennig, Steffen; Hernandez, Judith; Hinzmann, Bernd; Ho, Sarah; Hoffs, Michael; Howden, Phillip J.; Huckle, Elizabeth J.; Hume, Jennifer; Hunt, Paul J.; Hunt, Adrienne R.; Isherwood, Judith; Jacob, Leni; Johnson, David; Jones, Sally; de Jong, Pieter J.; Joseph, Shirin S.; Keenan, Stephen; Kelly, Susan; Kershaw, Joanne K.; Khan, Ziad; Kioschis, Petra; Klages, Sven; Knights, Andrew J.; Kosiura, Anna; Kovar-Smith, Christie; Laird, Gavin K.; Langford, Cordelia; Lawlor, Stephanie; Leversha, Margaret; Lewis, Lora; Liu, Wen; Lloyd, Christine; Lloyd, David M.; Loulseged, Hermela; Loveland, Jane E.; Lovell, Jamieson D.; Lozado, Ryan; Lu, Jing; Lyne, Rachael; Ma, Jie; Maheshwari, Manjula; Matthews, Lucy H.; McDowall, Jennifer; McLaren, Stuart; McMurray, Amanda; Meidl, Patrick; Meitinger, Thomas; Milne, Sarah; Miner, George; Mistry, Shailesh L.; Morgan, Margaret; Morris, Sidney; Müller, Ines; Mullikin, James C.; Nguyen, Ngoc; Nordsiek, Gabriele; Nyakatura, Gerald; O’Dell, Christopher N.; Okwuonu, Geoffery; Palmer, Sophie; Pandian, Richard; Parker, David; Parrish, Julia; Pasternak, Shiran; Patel, Dina; Pearce, Alex V.; Pearson, Danita M.; Pelan, Sarah E.; Perez, Lesette; Porter, Keith M.; Ramsey, Yvonne; Reichwald, Kathrin; Rhodes, Susan; Ridler, Kerry A.; Schlessinger, David; Schueler, Mary G.; Sehra, Harminder K.; Shaw-Smith, Charles; Shen, Hua; Sheridan, Elizabeth M.; Shownkeen, Ratna; Skuce, Carl D.; Smith, Michelle L.; Sotheran, Elizabeth C.; Steingruber, Helen E.; Steward, Charles A.; Storey, Roy; Swann, R. Mark; Swarbreck, David; Tabor, Paul E.; Taudien, Stefan; Taylor, Tineace; Teague, Brian; Thomas, Karen; Thorpe, Andrea; Timms, Kirsten; Tracey, Alan; Trevanion, Steve; Tromans, Anthony C.; d’Urso, Michele; Verduzco, Daniel; Villasana, Donna; Waldron, Lenee; Wall, Melanie; Wang, Qiaoyan; Warren, James; Warry, Georgina L.; Wei, Xuehong; West, Anthony; Whitehead, Siobhan L.; Whiteley, Mathew N.; Wilkinson, Jane E.; Willey, David L.; Williams, Gabrielle; Williams, Leanne; Williamson, Angela; Williamson, Helen; Wilming, Laurens; Woodmansey, Rebecca L.; Wray, Paul W.; Yen, Jennifer; Zhang, Jingkun; Zhou, Jianling; Zoghbi, Huda; Zorilla, Sara; Buck, David; Reinhardt, Richard; Poustka, Annemarie; Rosenthal, André; Lehrach, Hans; Meindl, Alfons; Minx, Patrick J.; Hillier, LaDeana W.; Willard, Huntington F.; Wilson, Richard K.; Waterston, Robert H.; Rice, Catherine M.; Vaudin, Mark; Coulson, Alan; Nelson, David L.; Weinstock, George; Sulston, John E.; Durbin, Richard; Hubbard, Tim; Gibbs, Richard A.; Beck, Stephan; Rogers, Jane; Bentley, David R.

    2009-01-01

    The human X chromosome has a unique biology that was shaped by its evolution as the sex chromosome shared by males and females. We have determined 99.3% of the euchromatic sequence of the X chromosome. Our analysis illustrates the autosomal origin of the mammalian sex chromosomes, the stepwise process that led to the progressive loss of recombination between X and Y, and the extent of subsequent degradation of the Y chromosome. LINE1 repeat elements cover one-third of the X chromosome, with a distribution that is consistent with their proposed role as way stations in the process of X-chromosome inactivation. We found 1,098 genes in the sequence, of which 99 encode proteins expressed in testis and in various tumour types. A disproportionately high number of mendelian diseases are documented for the X chromosome. Of this number, 168 have been explained by mutations in 113 X-linked genes, which in many cases were characterized with the aid of the DNA sequence. PMID:15772651

  5. Treatment of foods with high-energy X rays

    International Nuclear Information System (INIS)

    Cleland, M.R.; Meissner, J.; Herer, A.S.; Beers, E.W.

    2001-01-01

    The treatment of foods with ionizing energy in the form of gamma rays, accelerated electrons, and X rays can produce beneficial effects, such as inhibiting the sprouting in potatoes, onions, and garlic, controlling insects in fruits, vegetables, and grains, inhibiting the growth of fungi, pasteurizing fresh meat, poultry, and seafood, and sterilizing spices and food additives. After many years of research, these processes have been approved by regulatory authorities in many countries and commercial applications have been increasing. High-energy X rays are especially useful for treating large packages of food. The most attractive features are product penetration, absorbed dose uniformity, high utilization efficiency and short processing time. The ability to energize the X-ray source only when needed enhances the safety and convenience of this technique. The availability of high-energy, high-power electron accelerators, which can be used as X-ray generators, makes it feasible to process large quantities of food economically. Several industrial accelerator facilities already have X-ray conversion equipment and several more will soon be built with product conveying systems designed to take advantage of the unique characteristics of high-energy X rays. These concepts will be reviewed briefly in this paper

  6. Treatment of foods with high-energy X rays

    Science.gov (United States)

    Cleland, M. R.; Meissner, J.; Herer, A. S.; Beers, E. W.

    2001-07-01

    The treatment of foods with ionizing energy in the form of gamma rays, accelerated electrons, and X rays can produce beneficial effects, such as inhibiting the sprouting in potatoes, onions, and garlic, controlling insects in fruits, vegetables, and grains, inhibiting the growth of fungi, pasteurizing fresh meat, poultry, and seafood, and sterilizing spices and food additives. After many years of research, these processes have been approved by regulatory authorities in many countries and commercial applications have been increasing. High-energy X rays are especially useful for treating large packages of food. The most attractive features are product penetration, absorbed dose uniformity, high utilization efficiency and short processing time. The ability to energize the X-ray source only when needed enhances the safety and convenience of this technique. The availability of high-energy, high-power electron accelerators, which can be used as X-ray generators, makes it feasible to process large quantities of food economically. Several industrial accelerator facilities already have X-ray conversion equipment and several more will soon be built with product conveying systems designed to take advantage of the unique characteristics of high-energy X rays. These concepts will be reviewed briefly in this paper.

  7. X-rays from stars

    Science.gov (United States)

    Güdel, Manuel

    2004-07-01

    Spectroscopic studies available from Chandra and XMM-Newton play a pivotal part in the understanding of the physical processes in stellar (magnetic and non-magnetic) atmospheres. It is now routinely possible to derive densities and to study the influence of ultraviolet radiation fields, both of which can be used to infer the geometry of the radiating sources. Line profiles provide important information on bulk mass motions and attenuation by neutral matter, e.g. in stellar winds. The increased sensitivity has revealed new types of X-ray sources in systems that were thought to be unlikely places for X-rays: flaring brown dwarfs, including rather old, non-accreting objects, and terminal shocks in jets of young stars are important examples. New clues concerning the role of stellar high-energy processes in the modification of the stellar environment (ionization, spallation, etc.) contribute significantly to our understanding of the "astro-ecology" in forming planetary systems. Technological limitations are evident. The spectral resolution has not reached the level where bulk mass motions in cool stars become easily measurable. Higher resolution would also be important to perform X-ray "Doppler imaging" in order to reconstruct the 3-D distribution of the X-ray sources around a rotating star. Higher sensitivity will be required to perform high-resolution spectroscopy of weak sources such as brown dwarfs or embedded pre-main-sequence sources. A new generation of satellites such as Constellation-X or XEUS should pursue these goals.

  8. Immunocytochemical analysis of P2X2 in rat circumvallate taste buds

    Directory of Open Access Journals (Sweden)

    Yang Ruibiao

    2012-05-01

    Full Text Available Abstract Background Our laboratory has shown that classical synapses and synaptic proteins are associated with Type III cells. Yet it is generally accepted that Type II cells transduce bitter, sweet and umami stimuli. No classical synapses, however, have been found associated with Type II cells. Recent studies indicate that the ionotropic purinergic receptors P2X2/P2X3 are present in rodent taste buds. Taste nerve processes express the ionotropic purinergic receptors (P2X2/P2X3. P2X2/P2X3Dbl−/− mice are not responsive to sweet, umami and bitter stimuli, and it has been proposed that ATP acts as a neurotransmitter in taste buds. The goal of the present study is to learn more about the nature of purinergic contacts in rat circumvallate taste buds by examining immunoreactivity to antisera directed against the purinergic receptor P2X2. Results P2X2-like immunoreactivity is present in intragemmal nerve processes in rat circumvallate taste buds. Intense immunoreactivity can also be seen in the subgemmal nerve plexuses located below the basal lamina. The P2X2 immunoreactive nerve processes also display syntaxin-1-LIR. The immunoreactive nerves are in close contact with the IP3R3-LIR Type II cells and syntaxin-1-LIR and/or 5-HT-LIR Type III cells. Taste cell synapses are observed only from Type III taste cells onto P2X2-LIR nerve processes. Unusually large, “atypical” mitochondria in the Type II taste cells are found only at close appositions with P2X2-LIR nerve processes. P2X2 immunogold particles are concentrated at the membranes of nerve processes at close appositions with taste cells. Conclusions Based on our immunofluorescence and immunoelectron microscopical studies we believe that both perigemmal and most all intragemmal nerve processes display P2X2-LIR. Moreover, colloidal gold immunoelectron microscopy indicates that P2X2-LIR in nerve processes is concentrated at sites of close apposition with Type II cells. This supports the hypothesis

  9. Optical and X-ray studies of Compact X-ray Binaries in NGC 5904

    Science.gov (United States)

    Bhalotia, Vanshree; Beck-Winchatz, Bernhard

    2018-06-01

    Due to their high stellar densities, globular cluster systems trigger various dynamical interactions, such as the formation of compact X-ray binaries. Stellar collisional frequencies have been correlated to the number of X-ray sources detected in various clusters and we hope to measure this correlation for NGC 5904. Optical fluxes of sources from archival HST images of NGC 5904 have been measured using a DOLPHOT PSF photometry in the UV, optical and near-infrared. We developed a data analysis pipeline to process the fluxes of tens of thousands of objects using awk, python and DOLPHOT. We plot color magnitude diagrams in different photometric bands in order to identify outliers that could be X-ray binaries, since they do not evolve the same way as singular stars. Aligning previously measured astrometric data for X-ray sources in NGC 5904 from Chandra with archival astrometric data from HST will filter out the outlier objects that are not X-ray producing, and provide a sample of compact binary systems that are responsible for X-ray emission in NGC 5904. Furthermore, previously measured X-ray fluxes of NGC 5904 from Chandra have also been used to measure the X-ray to optical flux ratio and identify the types of compact X-ray binaries responsible for the X-ray emissions in NGC 5904. We gratefully acknowledge the support from the Illinois Space Grant Consortium.

  10. Ebselen (PZ-51) protects the Caudate putamen against hypoxia/ischemia induced neuronal damage.

    NARCIS (Netherlands)

    Knollema, S; Elting, JW; Dijkhuizen, RM; Nicolay, K; Korf, J; TerHorst, GJ

    1996-01-01

    Ebselen, a synthetic selenium-containing compound which exhibits glutathione peroxidase-like activity in vivo, is known for its beneficial effects on inflammation and tissue injury. Experiments were conducted to test whether ebselen dissolved in DiMethylSulfOxide (DMSO) could prevent damage in a rat

  11. Ebselen (PZ-51) protects the caudate putamen against hypoxia/ischemia induced neuronal damage

    NARCIS (Netherlands)

    Knollema, S.; Elting, J.W.; Dijkhuizen, R.M.; Nicolaij, K.; Korf, J.; Horst, ter G.J.

    1996-01-01

    Ebselen, a synthetic selenium-containing compound which exhibits glutathione peroxidase-like activity in vivo, is known for its beneficial effects on inflammation and tissue injury. Experiments were conducted to test whether ebselen dissolved in DiMethylSulfOxide (DMSO) could prevent damage in a rat

  12. X-ray scattering studies of non-equilibrium ordering processes

    International Nuclear Information System (INIS)

    Nagler, S.E.

    1992-01-01

    This report summarizes the major results obtained under US DOE Grant Number FG05-90ER45280 from the dates November 1, 1989 through October 31, 1992 inclusive. The principal work includes x-ray scattering studies of phase transition kinetics in binary alloy order-disorder transitions, block co-polymer crystallization, and charge density wave solids under applied electric fields, and studies of magnetic excitations in low dimensional quantum systems

  13. Thermodynamic Factors Affecting UC1-xNxIrradiation and Synthesis

    Energy Technology Data Exchange (ETDEWEB)

    Lindemer, T.B.

    2005-04-22

    There is interest in attempting to synthesize nearly pure uranium nitride (UN) kernels for high-temperature gas-cooled reactor (HTGR) fuel. Because the proposed process involves carbothermic conversion of a urania-carbon mixture in nitrogen and because there is a complete ideal solution of uranium carbide (UC) and UN, which is written as UC{sub 1-x}N{sub x}, the practical value of x for fuel irradiation needs to be determined. Insight is to be gained by relevant thermodynamic calculations of carbide-nitride equilibria for the fuel and fission product systems. The equilibria are readily compared on the nitrogen-based Ellingham diagram, which, in turn, provides guidance in interpreting past irradiations and in synthesis of the UC{sub 1-x}N{sub x} kernels.

  14. Measurement of Intervertebral Cervical Motion by Means of Dynamic X-Ray Image Processing and Data Interpolation

    Directory of Open Access Journals (Sweden)

    Paolo Bifulco

    2013-01-01

    Full Text Available Accurate measurement of intervertebral kinematics of the cervical spine can support the diagnosis of widespread diseases related to neck pain, such as chronic whiplash dysfunction, arthritis, and segmental degeneration. The natural inaccessibility of the spine, its complex anatomy, and the small range of motion only permit concise measurement in vivo. Low dose X-ray fluoroscopy allows time-continuous screening of cervical spine during patient’s spontaneous motion. To obtain accurate motion measurements, each vertebra was tracked by means of image processing along a sequence of radiographic images. To obtain a time-continuous representation of motion and to reduce noise in the experimental data, smoothing spline interpolation was used. Estimation of intervertebral motion for cervical segments was obtained by processing patient’s fluoroscopic sequence; intervertebral angle and displacement and the instantaneous centre of rotation were computed. The RMS value of fitting errors resulted in about 0.2 degree for rotation and 0.2 mm for displacements.

  15. Measurement of intervertebral cervical motion by means of dynamic x-ray image processing and data interpolation.

    Science.gov (United States)

    Bifulco, Paolo; Cesarelli, Mario; Romano, Maria; Fratini, Antonio; Sansone, Mario

    2013-01-01

    Accurate measurement of intervertebral kinematics of the cervical spine can support the diagnosis of widespread diseases related to neck pain, such as chronic whiplash dysfunction, arthritis, and segmental degeneration. The natural inaccessibility of the spine, its complex anatomy, and the small range of motion only permit concise measurement in vivo. Low dose X-ray fluoroscopy allows time-continuous screening of cervical spine during patient's spontaneous motion. To obtain accurate motion measurements, each vertebra was tracked by means of image processing along a sequence of radiographic images. To obtain a time-continuous representation of motion and to reduce noise in the experimental data, smoothing spline interpolation was used. Estimation of intervertebral motion for cervical segments was obtained by processing patient's fluoroscopic sequence; intervertebral angle and displacement and the instantaneous centre of rotation were computed. The RMS value of fitting errors resulted in about 0.2 degree for rotation and 0.2 mm for displacements.

  16. Neutron radiography and X-ray computed tomography for quantifying weathering and water uptake processes inside porous limestone used as building material

    International Nuclear Information System (INIS)

    Dewanckele, J.; De Kock, T.; Fronteau, G.; Derluyn, H.; Vontobel, P.; Dierick, M.; Van Hoorebeke, L.; Jacobs, P.; Cnudde, V.

    2014-01-01

    Euville and Savonnières limestones were weathered by acid test and this resulted in the formation of a gypsum crust. In order to characterize the crystallization pattern and the evolution of the pore structure below the crust, a combination of high resolution X-ray computed tomography and SEM–EDS was used. A time lapse sequence of the changing pore structure in both stones was obtained and afterwards quantified by using image analysis. The difference in weathering of both stones by the same process could be explained by the underlying microstructure and texture. Because water and moisture play a crucial role in the weathering processes, water uptake in weathered and non-weathered samples was characterized based on neutron radiography. In this way the water uptake was both visualized and quantified in function of the height of the sample and in function of time. In general, the formation of a gypsum crust on limestone slows down the initial water uptake in the materials. - Highlights: • Time lapse sequence in 3D of changing pore structures inside limestone • A combination of X-ray CT, SEM and neutron radiography was used. • Quantification of water content in function of time, height and weathering • Characterization of weathering processes due to gypsum crystallization

  17. X-CHIP: an integrated platform for high-throughput protein crystallization and on-the-chip X-ray diffraction data collection

    International Nuclear Information System (INIS)

    Kisselman, Gera; Qiu, Wei; Romanov, Vladimir; Thompson, Christine M.; Lam, Robert; Battaile, Kevin P.; Pai, Emil F.; Chirgadze, Nickolay Y.

    2011-01-01

    The X-CHIP (X-ray Crystallography High-throughput Integrated Platform) is a novel microchip that has been developed to combine multiple steps of the crystallographic pipeline from crystallization to diffraction data collection on a single device to streamline the entire process. The X-CHIP (X-ray Crystallization High-throughput Integrated Platform) is a novel microchip that has been developed to combine multiple steps of the crystallographic pipeline from crystallization to diffraction data collection on a single device to streamline the entire process. The system has been designed for crystallization condition screening, visual crystal inspection, initial X-ray screening and data collection in a high-throughput fashion. X-ray diffraction data acquisition can be performed directly on-the-chip at room temperature using an in situ approach. The capabilities of the chip eliminate the necessity for manual crystal handling and cryoprotection of crystal samples, while allowing data collection from multiple crystals in the same drop. This technology would be especially beneficial for projects with large volumes of data, such as protein-complex studies and fragment-based screening. The platform employs hydrophilic and hydrophobic concentric ring surfaces on a miniature plate transparent to visible light and X-rays to create a well defined and stable microbatch crystallization environment. The results of crystallization and data-collection experiments demonstrate that high-quality well diffracting crystals can be grown and high-resolution diffraction data sets can be collected using this technology. Furthermore, the quality of a single-wavelength anomalous dispersion data set collected with the X-CHIP at room temperature was sufficient to generate interpretable electron-density maps. This technology is highly resource-efficient owing to the use of nanolitre-scale drop volumes. It does not require any modification for most in-house and synchrotron beamline systems and offers

  18. X-CHIP: an integrated platform for high-throughput protein crystallization and on-the-chip X-ray diffraction data collection

    Energy Technology Data Exchange (ETDEWEB)

    Kisselman, Gera; Qiu, Wei; Romanov, Vladimir; Thompson, Christine M.; Lam, Robert [Ontario Cancer Institute, Princess Margaret Hospital, University Health Network, Toronto, Ontario M5G 2C4 (Canada); Battaile, Kevin P. [Argonne National Laboratory, Argonne, Illinois 60439 (United States); Pai, Emil F.; Chirgadze, Nickolay Y., E-mail: nchirgad@uhnresearch.ca [Ontario Cancer Institute, Princess Margaret Hospital, University Health Network, Toronto, Ontario M5G 2C4 (Canada); University of Toronto, Toronto, Ontario M5S 1A8 (Canada)

    2011-06-01

    The X-CHIP (X-ray Crystallography High-throughput Integrated Platform) is a novel microchip that has been developed to combine multiple steps of the crystallographic pipeline from crystallization to diffraction data collection on a single device to streamline the entire process. The X-CHIP (X-ray Crystallization High-throughput Integrated Platform) is a novel microchip that has been developed to combine multiple steps of the crystallographic pipeline from crystallization to diffraction data collection on a single device to streamline the entire process. The system has been designed for crystallization condition screening, visual crystal inspection, initial X-ray screening and data collection in a high-throughput fashion. X-ray diffraction data acquisition can be performed directly on-the-chip at room temperature using an in situ approach. The capabilities of the chip eliminate the necessity for manual crystal handling and cryoprotection of crystal samples, while allowing data collection from multiple crystals in the same drop. This technology would be especially beneficial for projects with large volumes of data, such as protein-complex studies and fragment-based screening. The platform employs hydrophilic and hydrophobic concentric ring surfaces on a miniature plate transparent to visible light and X-rays to create a well defined and stable microbatch crystallization environment. The results of crystallization and data-collection experiments demonstrate that high-quality well diffracting crystals can be grown and high-resolution diffraction data sets can be collected using this technology. Furthermore, the quality of a single-wavelength anomalous dispersion data set collected with the X-CHIP at room temperature was sufficient to generate interpretable electron-density maps. This technology is highly resource-efficient owing to the use of nanolitre-scale drop volumes. It does not require any modification for most in-house and synchrotron beamline systems and offers

  19. Estudo do comportamento do aço API 5L X80 quando submetido à soldagem por processo automatizado Study on the behavior of API 5L X80 steel when subjected to automated welding process

    Directory of Open Access Journals (Sweden)

    Siderley Fernandes Albuquerque

    2012-06-01

    Full Text Available No Brasil, a soldagem de tubulações tem sido praticamente de forma manual, entretanto, a utilização de processos de soldagem automatizados têm crescido muito nos últimos anos, contribuindo para o maior controle dos parâmetros de soldagem, e conseqüentemente, a possibilidade de obtenção de juntas soldadas com melhores propriedades mecânicas. A soldagem de tubulações com aço API 5L X80 ainda vem sendo avaliada no Brasil no que diz respeito aos melhores procedimentos, parâmetros e processos de soldagem; a aplicação de processos automatizados nas condições específicas de campo constitui em uma opção ainda incipiente no país por se discutir ainda a relação custo/benefício com a sua implantação. Logo, o objetivo deste trabalho é avaliar o comportamento na ZTA de juntas soldadas do aço API 5L X80 utilizados para transporte de petróleo e gás quando submetidos à soldagem com diferentes parâmetros, procedimentos e processos de soldagem, incluindo o processo automatizado; os resultados indicam além da redução da extensão e do tamanho de grão da ZTA a preservação da estrutura bainítica do metal de base nesta região nas soldagem executadas com processos automatizados.The welding of pipes has been largely manual in Brazil, however, the use of automated welding processes have greatly increased in recent years, contributing to greater control of welding parameters, and consequently, the possibility of obtaining welded joints with better mechanical properties. The welding of pipes of API 5L X80 steel has been evaluated in Brazil considering to best practices, parameters and welding processes; the implementation of automated processes in the specific field conditions is relevant project and innovative design in this area. Therefore, the objective is to evaluate the behavior in the HAZ of the API 5L X80 steel used for transporting oil and gas when subjected to automated welding processes; the results indicated besides the

  20. Interface dislocations in In{sub x}Ga{sub 1-x}N/GaN heterostructures

    Energy Technology Data Exchange (ETDEWEB)

    Li, Q.T.; Minj, A.; Chauvat, M.P.; Chen, J.; Ruterana, P. [CIMAP UMR 6252, CNRS ENSICAEN UCBN CEA, Caen (France)

    2017-04-15

    Interface dislocations have been investigated by transmission electron microscopy for In{sub x}Ga{sub 1-x}N (50 nm)/GaN heterostructures grown by metal-organic vapor phase epitaxy for 0.13 < x < 0.20. Structural properties of the dislocations were analysed by conventional transmission electron microscopy by diffraction contrast. We observed two kinds of dislocations lying in the interface: screw type dislocations with Burgers vector b = a = 1/3 <11-20> and pure edge misfit dislocations. The screw type dislocations were observed for x ≤ 0.17 and misfit dislocations for x ≥ 0.18. While the formation of MDs may be explained in the framework of conventional interface strain relaxation, the presence of screw-type dislocations may bring new insight on processes in hexagonal materials heteroepitaxy. (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  1. X-ray micro-tomography investigation of the foaming process in the system of waste glass–silica mud–MnO{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Ducman, V., E-mail: vilma.ducman@zag.si [ZAG Ljubljana, Dimičeva 12, 1000 Ljubljana (Slovenia); Korat, L.; Legat, A. [ZAG Ljubljana, Dimičeva 12, 1000 Ljubljana (Slovenia); Mirtič, B. [NTF, Aškerčeva 12, 1000 Ljubljana (Slovenia)

    2013-12-15

    In case of foamed lightweight aggregates (LWAs), porosity is introduced by the addition of a foaming agent to the glassy matrix, which degasses at an elevated temperature, so that the resulting gases remain trapped inside the glassy structure. The efficiency of action of MnO{sub 2} as a foaming agent in waste glass and waste glass/silica mud systems was studied. Samples were fired at different temperatures and with different dwelling times at a certain temperature, and the development of porosity was investigated by means of X-ray micro-tomography. It was found that, with the prolongation in dwelling times, the number of pores decreased, while, on the other hand, the volume of these pores increased, and that the addition of silica mud increases the foaming temperature and slows down the foaming process. - Highlights: • Preparation of lightweight aggregate from waste glass, silica sludge, and MnO{sub 2} • DTA/TG investigation of MnO{sub 2} • Characterization of pore-forming process by means of X-ray micro-tomography (μcT)

  2. X-ray emission from comets

    International Nuclear Information System (INIS)

    Dennerl, Konrad

    1999-01-01

    When comet Hyakutake (C/1996 B2) encountered Earth in March 1996 at a minimum distance of only 15 million kilometers (40 times the distance of the moon), x-ray and extreme ultraviolet emission was discovered for the first time from a comet. The observations were performed with the astronomy satellites ROSAT and EUVE. A systematic search for x-rays from comets in archival data, obtained during the ROSAT all-sky survey in 1990/91, resulted in the discovery of x-ray emission from four additional comets. They were detected at seven occasions in total, when they were optically 300 to 30 000 times fainter than Hyakutake. These findings indicated that comets represent a new class of celestial x-ray sources. Subsequent detections of x-ray emission from additional comets with the satellites ROSAT, EUVE, and BeppoSAX confirmed this conclusion. The x-ray observations have obviously revealed the presence of a process in comets which had escaped attention until recently. This process is most likely charge exchange between highly charged heavy ions in the solar wind and cometary neutrals. The solar wind, a stream of particles continuously emitted from the sun with ≅ 400 km s -1 , consists predominantly of protons, electrons, and alpha particles, but contains also a small fraction (≅0.1%) of highly charged heavier ions, such as C 6+ ,O 6+ ,Ne 8+ ,Si 9+ ,Fe 11+ . When these ions capture electrons from the cometary gas, they attain highly excited states and radiate a large fraction of their excitation energy in the extreme ultraviolet and x-ray part of the spectrum. Charge exchange reproduces the intensity, the morphology and the spectrum of the observed x-ray emission from comets very well

  3. Formation of Y(x)Nd(1-x) Ba2Cu3O(7-delta) (0 = or Acoustic Levitation

    Science.gov (United States)

    Gustafson, D. E.; Hofmeister, W. H.; Bayuzick, R. J.

    2001-01-01

    Melt processing of RE123 superconductors has gained importance in recent years. While the first high temperature superconductors (HTSCs) were made using traditional ceramic press and sinter technology, recent fabrication efforts have employed alternate processing techniques including laser ablation and ion beam assisted deposition for thin film fabrication of tapes and wires and melt growth for bulk materials. To optimize these techniques and identify other potential processing strategies, phase relation studies on HTSCs have been conducted on a wide variety of superconducting compounds using numerous processing strategies. This data has enhanced the understanding of these complex systems and allowed more accurate modeling of phase interactions. All of this research has proved useful in identifying processing capabilities for HTSCs but has failed to achieve a breakthrough for wide spread application of these materials. This study examines the role of full to partial substitution of Nd in the Y123 structure under rapid solidification conditions. Aero-acoustic levitation (AAL) was used to levitate and undercool RE123 in pure oxygen binary alloys with RE = Nd an Y along a range of compositions corresponding to Y(x)Nd(1-x) Ba2Cu3O(7-delta) (0 = or < x < or = 0.7) which were melted by a CO2 laser. Higher Y content spheres could not be melted in the AAL and were excluded from this report. Solidification structures were examined using scanning electron microscopy, electron dispersive spectroscopy, and powder x-ray diffraction to characterize microstructures and identify phases.

  4. Small angle X-ray scattering study on the conformation of polystyrene in the anti-solvent process of supercritical fluids

    International Nuclear Information System (INIS)

    Liu Yi; Wang Hongli; Zhao Xin; Chen Na; Li Dan; Liu Zhimin; Han Buxing; Rong Lixia; Zhao Hui; Wang Jun; Dong Baozhong

    2003-01-01

    The conformation of polystyrene in the anti-solvent process of supercritical fluids (compressed CO 2 + polystyrene + tetrahydrofuran) is studied by synchrotron radiation X-ray small angle scattering (SAXS). Coil-to-globule transform of polystyrene chain is observed with increasing the concentration of CO 2 . It is found that polystyrene coils at the pressure lower than cloud point pressure (p c ) and changes into globule with uniform density at the pressure higher than p c

  5. Fundamentals of energy dispersive X-ray analysis

    CERN Document Server

    Russ, John C; Kiessling, R; Charles, J

    1984-01-01

    Fundamentals of Energy Dispersive X-ray Analysis provides an introduction to the fundamental principles of dispersive X-ray analysis. It presents descriptions, equations, and graphs to enable the users of these techniques to develop an intuitive and conceptual image of the physical processes involved in the generation and detection of X-rays. The book begins with a discussion of X-ray detection and measurement, which is accomplished by one of two types of X-ray spectrometer: energy dispersive or wavelength dispersive. The emphasis is on energy dispersive spectrometers, given their rather wid

  6. Characterization of Beryllium Windows for Coherent X-ray Optics

    International Nuclear Information System (INIS)

    Goto, Shunji; Yabashi, Makina; Tamasaku, Kenji; Ishikawa, Tetsuya

    2007-01-01

    Beryllium foils fabricated by several processes were characterized using spatially coherent x rays at 1-km beamline of SPring-8. By thickness dependence of bright x-ray spot density due to Fresnel diffraction from several-micron deficiencies, we found that speckles (bright x-ray spots) were due to voids with densities 103-104 mm-3 in powder foils and ingot foils. Compared with powder and ingot foils, a polished physical-vapor-deposited (PVD) beryllium foil gave highly uniform beams with no speckles. The PVD process eliminates the internal voids in principle and the PVD foil is the best for coherent x-ray applications

  7. A study of the x-ray image quality improvement in the examination of the respiratory system based on the new image processing technique

    Science.gov (United States)

    Nagai, Yuichi; Kitagawa, Mayumi; Torii, Jun; Iwase, Takumi; Aso, Tomohiko; Ihara, Kanyu; Fujikawa, Mari; Takeuchi, Yumiko; Suzuki, Katsumi; Ishiguro, Takashi; Hara, Akio

    2014-03-01

    Recently, the double contrast technique in a gastrointestinal examination and the transbronchial lung biopsy in an examination for the respiratory system [1-3] have made a remarkable progress. Especially in the transbronchial lung biopsy, better quality of x-ray fluoroscopic images is requested because this examination is performed under a guidance of x-ray fluoroscopic images. On the other hand, various image processing methods [4] for x-ray fluoroscopic images have been developed as an x-ray system with a flat panel detector [5-7] is widely used. A recursive filtering is an effective method to reduce a random noise in x-ray fluoroscopic images. However it has a limitation for its effectiveness of a noise reduction in case of a moving object exists in x-ray fluoroscopic images because the recursive filtering is a noise reduction method by adding last few images. After recursive filtering a residual signal was produced if a moving object existed in x-ray images, and this residual signal disturbed a smooth procedure of the examinations. To improve this situation, new noise reduction method has been developed. The Adaptive Noise Reduction [ANR] is the brand-new noise reduction technique which can be reduced only a noise regardless of the moving object in x-ray fluoroscopic images. Therefore the ANR is a very suitable noise reduction method for the transbronchial lung biopsy under a guidance of x-ray fluoroscopic images because the residual signal caused of the moving object in x-ray fluoroscopic images is never produced after the ANR. In this paper, we will explain an advantage of the ANR by comparing of a performance between the ANR images and the conventional recursive filtering images.

  8. Planetary X-ray studies: past, present and future

    Science.gov (United States)

    Branduardi-Raymont, Graziella

    2016-07-01

    Our solar system is a fascinating physics laboratory and X-ray observations are now firmly established as a powerful diagnostic tool of the multiple processes taking place in it. The science that X-rays reveal encompasses solar, space plasma and planetary physics, and the response of bodies in the solar system to the impact of the Sun's activity. This talk will review what we know from past observations and what we expect to learn in the short, medium and long term. Observations with Chandra and XMM-Newton have demonstrated that the origin of Jupiter's bright soft X-ray aurorae lies in the Charge eXchange (CX) process, likely to involve the interaction with atmospheric neutrals of local magnetospheric ions, as well as those carried in the solar wind. At higher energies electron bremsstrahlung is thought to be the X-ray emitting mechanism, while the whole planetary disk acts as a mirror for the solar X-ray flux via Thomson and fluorescent scattering. This 'X-ray mirror' phenomenon is all that is observed from Saturn's disk, which otherwise lacks X-ray auroral features. The Earth's X-ray aurora is bright and variable and mostly due to electron bremsstrahlung and line emission from atmospheric species. Un-magnetised planets, Venus and Mars, do not show X-ray aurorae but display the interesting combination of mirroring the solar X-ray flux and producing X-rays by Solar Wind Charge eXchange (SWCX) in their exospheres. These processes respond to different solar stimulation (photons and solar wind plasma respectively) hence their relative contributions are seen to vary according to the Sun's output. Present and future of planetary X-ray studies are very bright. We are preparing for the arrival of the Juno mission at Jupiter this summer and for coordinated observations with Chandra and XMM-Newton on the approach and later during Juno's orbital phase. These will allow direct correlation of the local plasma conditions with the X-ray emissions and the establishment of the

  9. Hyperfine characterization of the Ba Ti{sub 1-x} Hf{sub x} O{sub 3} for x = 0.20; Caracterizacion hiperfina de Ba Ti{sub 1-x} Hf{sub x} O{sub 3} para x 0.20

    Energy Technology Data Exchange (ETDEWEB)

    Ayala, Alexandro; Lopez-Garcia, Alberto [La Plata Univ. Nacional (Argentina). Dept. de Fisica

    1997-12-31

    It is known that the cation substitution in perovskites produce changes in the macroscopic properties of these materials. A case to study is for example the influence of cation B partially substituted by cation B{sup `} when ABO{sub 3} is ferroelectric, and A B{sup `}O{sub 3} is paraelectric. In this work the system Ba Ti{sub 1-x} Hf{sub x} O{sub 3} with x = 0.05, 0.10, 0.15 and 0.20 is studied by Perturbed Angular Correlations (Pac) in order to obtain microscopic information through the electric field gradient tensor (EFG) produced by electrons close to probes. Two hyperfine quadrupole interactions were detected. One interaction associated to probes with defects originated during the nuclear processes after neutron irradiation, and the other are located in B sites. At R T, the hyperfine parameters are analyzed in terms of Hf concentration. (author). 5 refs., 2 figs., 2 tabs.

  10. X-ray pulse wavefront metrology using speckle tracking

    International Nuclear Information System (INIS)

    Berujon, Sebastien; Ziegler, Eric; Cloetens, Peter

    2015-01-01

    The theoretical description and experimental implementation of a speckle-tracking-based instrument which permits the characterisation of X-ray pulse wavefronts. An instrument allowing the quantitative analysis of X-ray pulsed wavefronts is presented and its processing method explained. The system relies on the X-ray speckle tracking principle to accurately measure the phase gradient of the X-ray beam from which beam optical aberrations can be deduced. The key component of this instrument, a semi-transparent scintillator emitting visible light while transmitting X-rays, allows simultaneous recording of two speckle images at two different propagation distances from the X-ray source. The speckle tracking procedure for a reference-less metrology mode is described with a detailed account on the advanced processing schemes used. A method to characterize and compensate for the imaging detector distortion, whose principle is also based on speckle, is included. The presented instrument is expected to find interest at synchrotrons and at the new X-ray free-electron laser sources under development worldwide where successful exploitation of beams relies on the availability of an accurate wavefront metrology

  11. Structural and magnetic investigations of CaBaCo{sub 4−x}Fe{sub x}O{sub 7} solid solutions

    Energy Technology Data Exchange (ETDEWEB)

    Turkin, D.I., E-mail: turkin@ihim.uran.ru [Institute of Solid State Chemistry, Ural Branch of the Russian Academy of Sciences, Ekaterinburg GSP-145, 620990 (Russian Federation); Bazuev, G.V. [Institute of Solid State Chemistry, Ural Branch of the Russian Academy of Sciences, Ekaterinburg GSP-145, 620990 (Russian Federation); Korolev, A.V. [Institute of Metal Physics, Ural Branch of the Russian Academy of Sciences, 620041 Ekaterinburg GSP-145, 620999 (Russian Federation)

    2017-01-15

    Solid solutions of CaBaCo{sub 4−x}Fe{sub x}O{sub 7} (x=0, 0.05, 0.2, 1, 2) were synthesized by glycine-nitrate combustion process. Their structural and magnetic properties were characterized by means of x-ray diffraction and magnetization measurements. In the examined range of the solid solutions, their crystal lattice symmetry changes from orthorhombic with space group Pbn2{sub 1} (0<x<0.5) to hexagonal with space group P6{sub 3}mc (x>0.5). The magnetic measurements revealed that even small doping (x=0.05) of the transition metal sublattice noticeably suppresses ferrimagnetism of the parent compound and induces an AF transition at 88 K. An increase in the doping concentration lowers the frustration parameter |θ{sub CW}|/T{sub C} from 17.2 (for x=0.05) to 13.7 (for x=2) and strengthens the antiferromagnetic interactions, which manifests itself in the Curie–Weiss temperature (θ{sub CW}) growth. The samples with x=0.05 and x=0.2 also show an additional magnetic transition at temperatures T{sub g} (55 and 70 K respectively). The temperature irreversibility between the ZFC and FC magnetization curves may suggest the formation of a spin-glass state below that temperature. - Highlights: • CaBaCo{sub 4−x}Fe{sub x}O{sub 7} solid solutions were synthesized by glycine-nitrate process. • At x=1 symmetry became hexagonal instead orthorhombic. • Fe-doping abruptly suppresses ferrimagnetism of CaBaCo{sub 4}O{sub 7}. • Increase of x is followed by enhancing of antiferromagnetic interactions.

  12. CubeX: The CubeSAT X-ray Telescope for Elemental Abundance Mapping of Airless Bodies and X-ray Pulsar Navigation

    Science.gov (United States)

    Nittler, L. R.; Hong, J.; Kenter, A.; Romaine, S.; Allen, B.; Kraft, R.; Masterson, R.; Elvis, M.; Gendreau, K.; Crawford, I.; Binzel, R.; Boynton, W. V.; Grindlay, J.; Ramsey, B.

    2017-12-01

    The surface elemental composition of a planetary body provides crucial information about its origin, geological evolution, and surface processing, all of which can in turn provide information about solar system evolution as a whole. Remote sensing X-ray fluorescence (XRF) spectroscopy has been used successfully to probe the major-element compositions of airless bodies in the inner solar system, including the Moon, near-Earth asteroids, and Mercury. The CubeSAT X-ray Telescope (CubeX) is a concept for a 6U planetary X-ray telescope (36U with S/C), which utilizes Miniature Wolter-I X-ray optics (MiXO), monolithic CMOS and SDD X-ray sensors for the focal plane, and a Solar X-ray Monitor (heritage from the REXIS XRF instrument on NASA's OSIRIS-REx mission). CubeX will map the surface elemental composition of diverse airless bodies by spectral measurement of XRF excited by solar X-rays. The lightweight ( 1 kg) MiXO optics provide sub-arcminute resolution with low background, while the inherently rad-hard CMOS detectors provide improved spectral resolution ( 150 eV) at 0 °C. CubeX will also demonstrate X-ray pulsar timing based deep space navigation (XNAV). Successful XNAV will enable autonomous deep navigation with little to no support from the Deep Space Network, hence lowering the operation cost for many more planetary missions. Recently selected by NASA Planetary Science Deep Space SmallSat Studies, the first CubeX concept, designed to rideshare to the Moon as a secondary spacecraft on a primary mission, is under study in collaboration with the Mission Design Center at NASA Ames Research Center. From high altitude ( 6,000 km) frozen polar circular orbits, CubeX will study > 8 regions ( 110 km) of geological interest on the Moon over one year to produce a high resolution ( 2-3 km) elemental abundance map of each region. The novel focal plane design of CubeX also allows us to evaluate the performance of absolute navigation by sequential observations of several

  13. Magnetic x-ray microdiffraction

    Energy Technology Data Exchange (ETDEWEB)

    Evans, Paul G [Computer-Aided Engineering Center, University of Wisconsin, Madison, WI 53706 (United States); Isaacs, Eric D [Center for Nanoscale Materials, Argonne National Laboratory, Argonne, IL 60439 (United States)

    2006-08-07

    Magnetic x-ray microdiffraction uses the structural specificity of x-ray diffraction to probe complex magnetic structures at the length scales relevant to physical phenomena including domain dynamics and phase transitions. Conventional magnetic crystallography techniques such as neutron or x-ray diffraction lack this spatial resolution. The combination of both reciprocal space and real space resolution with a rich magnetic cross section allows new microscopy techniques to be developed and applied to magnetism at the scale of single domains. Potential applications include a wide range of magnetic problems in nanomagnetism, the interaction of strain, polarization and magnetization in complex oxides and spatially resolved studies of magnetic phase transitions. We present the physical basis for x-ray microdiffraction and magnetic scattering processes, review microdiffraction domain imaging techniques in antiferromagnetic and ferromagnetic materials and discuss potential directions for studies. (topical review)

  14. Tratamentos para superação de dormência em sementes de Enterolobium contortisiliquum (Vell. Morong

    Directory of Open Access Journals (Sweden)

    Allan Deyvid Pereira da Silva

    2014-06-01

    Full Text Available 1024x768 As sementes da espécie Enterolobium contortisiliquum, popularmente conhecida como tamboril, apresentam alto grau de dormência, resultando em baixos níveis de germinação, o que dificulta a produção de mudas. Este trabalho teve como objetivo testar a eficiência da escarificação química e em água fervente para superação da dormência tegumentar das sementes de tamboril, utilizando-se os seguintes tratamentos: imersão das sementes em ácido sulfúrico (96% PA por 15, 30, 45 e 60 min, seguidos por lavagem em água corrente por 10 min; e imersão em água fervente (≅100 °C por 2, 4 min e até o resfriamento. As sementes foram colocadas para germinar em rolos de papel tipo Germitest® e incubadas em BOD, a 27 °C e fotoperíodo de 12/12 (dia e noite. Avaliou-se a porcentagem de germinação e o índice de velocidade de germinação (IVG. Os resultados permitiram inferir que a imersão das sementes em ácido sulfúrico por 15, 30, 45 e 60 min, bem como em água fervente até o resfriamento, foram os tratamentos que apresentaram maior eficiência na superação da dormência de sementes de tamboril. Todavia, recomenda-se o tratamento em água fervente até o resfriamento, levando-se em consideração a facilidade operacional e a relação custo/benefício. Normal 0 21 false false false PT-BR X-NONE X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Tabela normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso

  15. Magnetic transition induced by mechanical deformation in Fe{sub 60}Al{sub 40−x}Si{sub x} ternary alloys

    Energy Technology Data Exchange (ETDEWEB)

    Legarra, E., E-mail: estibaliz.legarra@ehu.es [Dpto. Electricidad y Electronica, Universidad del Pais Vasco (UPV/EHU), CP. 644, 48080 Bilbao (Spain); Apiñaniz, E. [Dpto. Fisica Aplicada I, Universidad del Pais Vasco, Alameda de Urquijo s/n, 48013 Bilbao (Spain); Plazaola, F. [Dpto. Electricidad y Electronica, Universidad del Pais Vasco (UPV/EHU), CP. 644, 48080 Bilbao (Spain); Jimenez, J.A. [Centro Nacional de Investigaciones Metalurgicas (CENIM), Avda. Gregorio del amo 8, 28040 Madrid (Spain)

    2014-02-15

    Highlights: • Fe{sub 60}Al{sub 40−x}Si{sub x} alloys were disordered by means of planetary ball milling technique. • Paramagnetic to ferromagnetic transition is observed with disordering. • Si addition hinders the disordering process and the increase of the lattice parameter. • Si addition promotes the paramagnetic to ferromagnetic transition. -- Abstract: We have used Mössbauer spectroscopy and X-ray diffraction to study the influence of different Al/Si ratios on the structural and magnetic properties of the mechanically deformed Fe{sub 60}Al{sub 40−x}Si{sub x} alloys. The results indicate that ternary alloys also present the magnetic transition with disordering observed in binary Fe{sub 60}Al{sub 40} alloys. Besides, Si introduction has two opposite contributions. From a structural point of view, hinders the disordering process, but, from a magnetic point of view promotes the magnetic transition.

  16. UV written 1x8 optical splitters

    DEFF Research Database (Denmark)

    Olivero, Massimo; Svalgaard, Mikael

    2005-01-01

    In this paper the first demonstration of 1x8 optical power splitters made by direct UV writing is presented. Design and optimization of the process as well as the performance of the fabricated components are discussed.......In this paper the first demonstration of 1x8 optical power splitters made by direct UV writing is presented. Design and optimization of the process as well as the performance of the fabricated components are discussed....

  17. Magnetic Properties of (Nia-ZnbX Cu1-X Ferrite Nanoparticle Fabricated by Sol-Gel Process

    Directory of Open Access Journals (Sweden)

    Yang S.

    2017-06-01

    Full Text Available In future, more mobile devices with different frequencies will be used at the same time. Therefore, it is expected that the trouble caused by wave interference between devices will be further intensified. In order to prevent this trouble, investigation of selective frequency transmission or absorption material is required. In this paper, magnetic properties of nickel-zinc-copper ferrite nano powder was researched as wave absorber. (Nia-ZnbxCu1-xFe2O4(NZCF nanoparticles were fabricated by the sol-gel method. The influence of copper substitution on lattice parameter change was analyzed by X-ray diffraction (XRD, particle size was analyzed by scanning electron microscopy (SEM, and Magnetic properties analyzed by vibrating sample magnetometer (VSM. The NZCF and Nickel-zinc ferrite (NZF lattice parameter difference was 0.028 Å and particle size was calculated as 30 nm with the XRD peak. The VSM results of (Ni0.3-Zn0.30.6Cu1-0.6Fe2O4 annealed sample at 700°C for 3hous were 58.5 emu/g (Ms, 22.8 Oe (Hc. It was the most suitable magnetic properties for wave absorber in this investigation.

  18. Produção de bioetanol a partir de coproduto gerado no descaroçamento de azeitona

    Directory of Open Access Journals (Sweden)

    Vanessa Medeiros Pereira

    2015-09-01

    Full Text Available Na busca por fontes alternativas de energia menos poluentes e mais sustentáveis, o uso de resíduos agrícolas para a produção de biocombustíveis tem se mostrado uma alternativa promissora. Neste contexto, o presente trabalho teve como objetivo avaliar a viabilidade da produção do bioetanol a partir da polpa de azeitona, um coproduto gerado no processo de descaroçamento das azeitonas de mesa. Avaliaram-se dois tipos de hidrólise como prétratamentos: hidrólise via ácido clorídrico 1% e hidrólise por explosão a vapor com ácido sulfúrico 14%. O líquido hidrolisado foi fermentado por 4 dias à temperatura ambiente, utilizando-se a levedura Saccharomyces cerevisiae. O melhor rendimento em etanol (4,6% v/v foi obtido com a polpa pré tratada com ácido sulfúrico.

  19. Physical properties and microstructures of La_{1-{x}}Pr_{{x}}PO_4 monazite-ceramics

    Science.gov (United States)

    Thust, Anja; Hirsch, Antje; Haussühl, Eiken; Schrodt, Nadine; Loison, Lise; Schott, Petra; Peters, Lars; Roth, Georg; Winkler, Björn

    2018-04-01

    Synthetic La_{1-{x}}Pr_{{x}}PO_4 monazite-type powders and ceramics with 0 ≤ x ≤ 1 were analysed by scanning electron microscopy, high-temperature powder X-ray diffraction, dilatometry, and plane wave ultrasound spectroscopy. Ceramics were synthesised in a two-step sintering process at 1273 and 1573 K. Final densities were up to 99.3% of the theoretical densities. Each sample shows a homogeneous distribution of grain sizes, which increase with increasing sintering temperature. Grain sizes also depend on composition, with intermediate compositions yielding the largest grains. In-situ high-temperature powder X-ray diffraction shows that the volumetric thermal expansion coefficients of the monazite powders decrease with increasing Pr content. This behavior is not observed in dilatometry measurements of the bulk samples (ceramics) because their thermal expansion mainly depends on their density. Elastic properties show the same dependence on the density.

  20. X-ray Crystallography of Biological Macromolecules -RE ...

    Indian Academy of Sciences (India)

    trons of the atoms scatter X-rays and if identical molecules are arranged in a ... Institute of Science,. Bangalore. ... The first X-ray diffraction pictures were taken and the theory .... various processes involved in biological systems in detail. We.

  1. In-situ X-ray photoelectron spectroscopy characterization of Si interlayer based surface passivation process for AlGaAs/GaAs quantum wire transistors

    Energy Technology Data Exchange (ETDEWEB)

    Akazawa, Masamichi; Hasegawa, Hideki; Jia, Rui [Research Center for Integrated Quantum Electronics and Graduate School of Information Science and Technology, Hokkaido University, N-13, W-8, Sapporo 060-8628 (Japan)

    2007-04-15

    Detailed properties of the Si interface control layer (Si ICL)-based surface passivation structure are characterized by in-situ X-ray photoelectron spectroscopy (XPS) in an ultra-high vacuum multi-chamber system. Si ICLs were grown by molecular beam epitaxy (MBE) on GaAs and AlGaAs(001) and (111)B surfaces, and were partially converted to SiN{sub x} by nitrogen radical beam. Freshly MBE-grown clean GaAs and AlGaAs surfaces showed strong Fermi level pinning. Large shifts of the surface Fermi level position corresponding to reduction of pinning took place after Si ICL growth, particularly on (111)B surface (around 500 meV). However, subsequent surface nitridation increased pinning again. Then, a significant reduction of pinning was obtained by changing SiN{sub x} to silicon oxynitride by intentional air-exposure and subsequent annealing. This has led to realization of a stable passivation structure with an ultrathin oxynitride/Si ICL structure which prevented subcutaneous oxidation during further device processing under air-exposure. The Si-ICL-based passivation process was applied to surface passivation of quantum wire (QWR) transistors where anomalously large side-gating phenomenon was completely eliminated. (copyright 2007 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  2. X-ray of osteopathies

    International Nuclear Information System (INIS)

    Freyschmidt, J.

    1980-01-01

    Osteoporosis, osteomalcia, fibro-osteoclasia and osteosclerosis are essential reactions to pathologicometabolic processes of the bone. The X-ray film shows precisely which changes have taken place in the bone structure, thus supplying the means for an analysis based on anatomic pathology. These phenomena are discussed in detail, special attention being paid to structural modifications. Attention is also focused on the problems connected with X-ray technology. The value of direct and indirect magnification of the skeleton of the hand for the identification and classification of esteopathies is explained. Phenomena observed in X-ray films, such as enosteal erosion, intracortical longitudinal stripes or tunnelisation, as well as subperiostal absorption, can be of pathognomonic importance for certain osteopathies. (orig.) [de

  3. MSL Chemistry and Mineralogy X-Ray Diffraction X-Ray Fluorescence (CheMin) Instrument

    Science.gov (United States)

    Zimmerman, Wayne; Blake, Dave; Harris, William; Morookian, John Michael; Randall, Dave; Reder, Leonard J.; Sarrazin, Phillipe

    2013-01-01

    This paper provides an overview of the Mars Science Laboratory (MSL) Chemistry and Mineralogy Xray Diffraction (XRD), X-ray Fluorescence (XRF) (CheMin) Instrument, an element of the landed Curiosity rover payload, which landed on Mars in August of 2012. The scientific goal of the MSL mission is to explore and quantitatively assess regions in Gale Crater as a potential habitat for life - past or present. The CheMin instrument will receive Martian rock and soil samples from the MSL Sample Acquisition/Sample Processing and Handling (SA/SPaH) system, and process it utilizing X-Ray spectroscopy methods to determine mineral composition. The Chemin instrument will analyze Martian soil and rocks to enable scientists to investigate geophysical processes occurring on Mars. The CheMin science objectives and proposed surface operations are described along with the CheMin hardware with an emphasis on the system engineering challenges associated with developing such a complex instrument.

  4. X-real-time executive (X-RTE) an ultra-high reliable real-time executive for safety critical systems

    International Nuclear Information System (INIS)

    Suresh Babu, R.M.

    1995-01-01

    With growing number of application of computers in safety critical systems of nuclear plants there has been a need to assure high quality and reliability of the software used in these systems. One way to assure software quality is to use qualified software components. Since the safety systems and control systems are real-time systems there is a need for a real-time supervisory software to guarantee temporal response of the system. This report describes one such software package, called X-Real-Time Executive (or X-RTE), which was developed in Reactor Control Division, BARC. The report describes all the capabilities and unique features of X-RTE and compares it with a commercially available operating system. The features of X-RTE include pre-emptive scheduling, process synchronization, inter-process communication, multi-processor support, temporal support, debug facility, high portability, high reliability, high quality, and extensive documentation. Examples have been used very liberally to illustrate the underlying concepts. Besides, the report provides a brief description about the methods used, during the software development, to assure high quality and reliability of X-RTE. (author). refs., 11 figs., tabs

  5. Pulse X-radiation in flaw detection

    International Nuclear Information System (INIS)

    Vavilov, S.P.; Gorbunov, V.I.

    1985-01-01

    Principles of physical and engineering application of pulse X-radiation (PXR) of micro- and nanosecond duration for nondestructive testing of processes, materials and devices are given. Methods and devices, aimed at generating X-ray pulses, as well as their radiation and flow detection characteristics, and testing methods by means of PXR are considered

  6. Deposition and characterization of multilayers on thin foil x-ray mirrors for high-throughput x-ray telescopes

    DEFF Research Database (Denmark)

    Hussain, Ahsen M.; Joensen, Karsten D.; Hoeghoej, P.

    1996-01-01

    W/Si and Co/C multilayers have been deposited on epoxy- replicated Au mirrors from the ASTRO-E telescope project, SPectrum Roentgen Gamma (SRG) flight mirrors, DURAN glass substrates and Si witness wafers. A characterization of the multilayers with both hard x-rays and soft x-rays is presented....... This clearly indicates the effectiveness of the epoxy-replication process for the production of smooth substrates for multilayer deposition to be used in future x-ray telescopes....

  7. On the polarization mixing of X-rays

    International Nuclear Information System (INIS)

    Ohkawa, T.; Hashimoto, H.

    1984-01-01

    Relativistic quantum field theory is applied to discuss the process of interference of white X-rays and the mechanism of rotation of the polarization of X-rays in crystals. A two-photon state is studied theoretically for analyzing the mechanism of the polarization mixing. Diffracted X-ray photons are produced by two successive stages of interaction between incident X-rays and electrons in a crystal. A dispersion relation of diffracted X-rays similar to Laue's dynamic theory is shown by use of the S-matrix. A dynamical structure factor is defined on the base of Dirac's γ-matrix. (author)

  8. Crystallization study of amorphous system Fe[sub 84-x]W[sub x]B[sub 16] (x = 3; 5)

    Energy Technology Data Exchange (ETDEWEB)

    Novakova, A.A.; Sidorova, G.V.; Kiseleva, T.Yu.; Szasz, A. (Dept. of Physics, State Univ., Moscow (Russia) Inst. of Metallurgy, Academy of Science, Moscow (Russia) Eoetvoes Univ., Budapest (Hungary))

    1992-10-01

    A complex study of the crystallization process of the amorphous system was carried out by Moessbauer spectroscopy, X-ray diffraction and DTA. Alloy samples crystallized at 600deg C contain the following phases: [alpha]-Fe, Fe[sub 3]B and solid solution (Fe, W)[sub 3]B. (orig.).

  9. Synthesis of LaO1-xFxFeAs (x=0-0.15) via solid state metathesis reaction

    Science.gov (United States)

    Frankovsky, Rainer; Marchuk, Alexey; Pobel, Roman; Johrendt, Dirk

    2012-04-01

    LaOFeAs and superconducting LaO1-xFxFeAs have been synthesized via salt metathesis reactions and characterized by X-ray powder diffraction and magnetic susceptibility measurements. The process uses LaOCl and NaFeAs as precursors and yielded very pure samples. Superconductivity was confirmed in samples with x=0.05, 0.10 and 0.15 at critical temperatures of 11 K, 26 K and 9 K, respectively. According to temperature-dependent X-ray diffraction data, the reaction pathway is not topotactic in contrast to earlier suggestions.

  10. Structure and superconductivity of room temperature chemically oxidized La2-xNdxCuO4+y (0<=x<=0.5)

    DEFF Research Database (Denmark)

    Rial, C.; Moran, E.; Alario-Franco, M.A.

    1997-01-01

    -doping increases, probably due to the progressive contraction of the structure along the c-axis. Analogies and differences in the modifications induced by the oxidation process in the present La2-xNdxCuO4+y materials and in related compounds La2-x(Ca/Sr/Ba)(x)CuO4+y (x less than or equal to 0.15) are reported...

  11. Fiscal 1998 research achievement report. Project for developing key technologies for electronic devices (Projection X-ray exposure process technology and active reflective device structure technology); 1998 nendo denshi device kiban gijutsu kaihatsu jigyo seika hokokusho. Shukusho X sen roko process gijutsu to active hansha kozogata keisei gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-05-01

    Studies were conducted for the development of technologies of the very advanced level relating to an ultrafine machining process and high-performance reflector type liquid crystal display structure formation. Studied in the research and development of projection X-ray exposure process technology were multi-layer film formation, absorbing body film formation, absorbing body machining, multi-layer film mask defect evaluation, and cleaning for defect reduction. As the result, multi-layer film formation by Helicon sputtering and formation and machining of film with Ta acting as absorbing body therein were carried out, and it was found by actual exposure experiments that there were excellent X-ray reflectivity and absorbing body contrast. Furthermore, a study was made of cleaning using dummy foreign matters, and 100% removal of dummy foreign matters was achieved across a range up to the 70nm level. Studied in the development of active reflective device structure technology were the addition of an electrical control function to the reflector, addition of an unreflected rays absorbing function, production of a bias stabilized device for the practical application of a memory function, and the development of materials for the fabrication of the said devices. (NEDO)

  12. A study of internal structure in components made by additive manufacturing process using 3 D X-ray tomography

    Energy Technology Data Exchange (ETDEWEB)

    Raguvarun, K., E-mail: prajagopal@iitm.ac.in; Balasubramaniam, Krishnan, E-mail: prajagopal@iitm.ac.in; Rajagopal, Prabhu, E-mail: prajagopal@iitm.ac.in [Centre for NDE, Indian Institute of Technology Madras, Chennai 600036, Tamilnadu (India); Palanisamy, Suresh [Swinburne University of Technology, Faculty of Engineering, Science and Technology, Hawthorn, Victoria 3122 Australia and Defence Materials Technology Centre, Hawthorn, Victoria 3122 (Australia); Nagarajah, Romesh; Kapoor, Ajay [Swinburne University of Technology, Faculty of Engineering, Science and Technology, Hawthorn, Victoria 3122 (Australia); Hoye, Nicholas; Curiri, Dominic [University of Wollongong, Faculty of Engineering, New South Wales 2522, Australia and Defence Materials Technology Centre, Hawthorn, Victoria 3122 (Australia)

    2015-03-31

    Additive manufacturing methods are gaining increasing popularity for rapidly and efficiently manufacturing parts and components in the industrial context, as well as for domestic applications. However, except when used for prototyping or rapid visualization of components, industries are concerned with the load carrying capacity and strength achievable by additive manufactured parts. In this paper, the wire-arc additive manufacturing (AM) process based on gas tungsten arc welding (GTAW) has been examined for the internal structure and constitution of components generated by the process. High-resolution 3D X-ray tomography is used to gain cut-views through wedge-shaped parts created using this GTAW additive manufacturing process with titanium alloy materials. In this work, two different control conditions for the GTAW process are considered. The studies reveal clusters of porosities, located in periodic spatial intervals along the sample cross-section. Such internal defects can have a detrimental effect on the strength of the resulting AM components, as shown in destructive testing studies. Closer examination of this phenomenon shows that defect clusters are preferentially located at GTAW traversal path intervals. These results highlight the strong need for enhanced control of process parameters in ensuring components with minimal defects and higher strength.

  13. A study of internal structure in components made by additive manufacturing process using 3 D X-ray tomography

    International Nuclear Information System (INIS)

    Raguvarun, K.; Balasubramaniam, Krishnan; Rajagopal, Prabhu; Palanisamy, Suresh; Nagarajah, Romesh; Kapoor, Ajay; Hoye, Nicholas; Curiri, Dominic

    2015-01-01

    Additive manufacturing methods are gaining increasing popularity for rapidly and efficiently manufacturing parts and components in the industrial context, as well as for domestic applications. However, except when used for prototyping or rapid visualization of components, industries are concerned with the load carrying capacity and strength achievable by additive manufactured parts. In this paper, the wire-arc additive manufacturing (AM) process based on gas tungsten arc welding (GTAW) has been examined for the internal structure and constitution of components generated by the process. High-resolution 3D X-ray tomography is used to gain cut-views through wedge-shaped parts created using this GTAW additive manufacturing process with titanium alloy materials. In this work, two different control conditions for the GTAW process are considered. The studies reveal clusters of porosities, located in periodic spatial intervals along the sample cross-section. Such internal defects can have a detrimental effect on the strength of the resulting AM components, as shown in destructive testing studies. Closer examination of this phenomenon shows that defect clusters are preferentially located at GTAW traversal path intervals. These results highlight the strong need for enhanced control of process parameters in ensuring components with minimal defects and higher strength

  14. Amorphization and crystallization of Zr{sub 66.7-x}Cu{sub 33.3}Nb{sub x} (x = 0, 2, 4) alloys during mechanical alloying

    Energy Technology Data Exchange (ETDEWEB)

    Wang Yan [Key Laboratory of Liquid Structure and Heredity of Materials, Shandong University, 73 Jingshi Road, Jinan 250061 (China); School of Materials Science and Engineering, University of Jinan, 106 Jiwei Road, Jinan 250022 (China); Chen Xiuxiu [School of Materials Science and Engineering, University of Jinan, 106 Jiwei Road, Jinan 250022 (China); Geng Haoran [School of Materials Science and Engineering, University of Jinan, 106 Jiwei Road, Jinan 250022 (China)], E-mail: mse_wangy@ujn.edu.cn; Yang Zhongxi [Key Laboratory of Liquid Structure and Heredity of Materials, Shandong University, 73 Jingshi Road, Jinan 250061 (China); School of Materials Science and Engineering, University of Jinan, 106 Jiwei Road, Jinan 250022 (China)

    2009-04-17

    In the present paper, the effect of Nb and different rotation speeds on the amorphization and crystallization of Zr{sub 66.7-x}Cu{sub 33.3}Nb{sub x} (x = 0, 2, 4) alloys during mechanical alloying has been investigated using X-ray diffraction (XRD), transmission electron microscopy (TEM), scanning electron microscopy (SEM), and differential scanning calorimetry (DSC). The results show that the minor addition of Nb can shorten the start time of the amorphization reaction, improve the glass forming ability of Zr-Cu alloys, but cannot promote the formation of a single amorphous phase at a lower rotation speed of 200 rpm. The glass forming ability of the Zr{sub 66.7-x}Cu{sub 33.3}Nb{sub x} (x = 0, 2, 4) alloys increases with increasing Nb additions. At a higher rotation speed of 350 rpm, a single amorphous phase of Zr{sub 66.7-x}Cu{sub 33.3}Nb{sub x} (x = 0, 2, 4) can be successfully fabricated. Moreover, the Nb addition into Zr-Cu alloys can accelerate the amorphization process and improve the stability of the amorphous phase against the mechanically induced crystallization. Furthermore, the amorphous Zr{sub 66.7}Cu{sub 33.3} phase gradually transforms into a metastable fcc-Zr{sub 2}Cu phase with increasing milling time.

  15. Fabrication of Coaxial Si(1-x)Ge(x) Heterostructure Nanowires by O(2) Flow-Induced Bifurcate Reactions.

    Science.gov (United States)

    Kim, Ilsoo; Lee, Ki-Young; Kim, Ungkil; Park, Yong-Hee; Park, Tae-Eon; Choi, Heon-Jin

    2010-06-17

    We report on bifurcate reactions on the surface of well-aligned Si(1-x)Ge(x) nanowires that enable fabrication of two different coaxial heterostructure nanowires. The Si(1-x)Ge(x) nanowires were grown in a chemical vapor transport process using SiCl(4) gas and Ge powder as a source. After the growth of nanowires, SiCl(4) flow was terminated while O(2) gas flow was introduced under vacuum. On the surface of nanowires was deposited Ge by the vapor from the Ge powder or oxidized into SiO(2) by the O(2) gas. The transition from deposition to oxidation occurred abruptly at 2 torr of O(2) pressure without any intermediate region and enables selectively fabricated Ge/Si(1-x)Ge(x) or SiO(2)/Si(1-x)Ge(x) coaxial heterostructure nanowires. The rate of deposition and oxidation was dominated by interfacial reaction and diffusion of oxygen through the oxide layer, respectively.

  16. Seasonal Adjustment with the R Packages x12 and x12GUI

    Directory of Open Access Journals (Sweden)

    Alexander Kowarik

    2014-12-01

    The provision of the powerful X-12-ARIMA seasonal adjustment program available directly from within R, as well as of the new facilities for marking outliers, batch processing and change tracking, makes the package a potent and functional tool.

  17. Structural and thermodynamic characteristics of X2MYH2 compounds (M Al, Ga, In; X = F, Cl, Br, I; Y = N, P, As) - the products of hydrohalogen elimination from X3MYH3 donor-acceptor complexes

    International Nuclear Information System (INIS)

    Timoshkin, A.Yu.; Suvorov, A.V.; Shefer, G.F.

    2001-01-01

    Geometrical and thermodynamic characteristics of complexes X 2 MYH 2 (M Al, Ga, In; X = F, Cl, Br, I; Y = N, P, As) were obtained by the method of density functional B3LYP. It is shown that nitrogen complexes X 2 MNH 2 have a plane structure, whereas phosphorus and arsenic complexes are pyramidal. In the process of HX elimination the dissociation energy of M-Y bond is strengthened essentially (by 150-270 kJ/mol), which makes dissociation of X 2 MYH 2 into components quite inefficient from thermodynamic viewpoint even at temperatures of about 1000 deg C. Dimerization enthalpies of X 2 MYH 2 lie in the range 40 (Y = P, As) - 260 (Y=N) kJ/mol. Thus, dimers [X 2 MNH 2 ] 2 can be intermediate products in the processes of nitrides chemical precipitation from gaseous phase of donor-acceptor complexes [ru

  18. Decision Making Processes for a Pregnant Woman Admitted to the Accident and Emergency Department Requiring Emergency Diagnostic X-ray – A Case Study

    Directory of Open Access Journals (Sweden)

    S. Ismanto

    2017-07-01

    Full Text Available The objective of this study is to apply the decision-making processes for a pregnant woman who was involved in a motor vehicle accident and admitted to a private middle-class hospital in the capital of Indonesia requiring radiologic X-ray examination.  It also aims to examine and evaluate the patient who was in her 20th week of gestation in order to provide her with the best emergency care, diagnostic investigations and treatments.The descriptive, normative and prescriptive models of decision-making are demonstrated. The descriptive model used intuition, while the normative model used decision trees as decision options and lastly the prescriptive decision used the information processing theory (IPT to decide on the best emergency care, diagnostic investigations and treatments for the patient. The IPT dominated the decision-making process; hence an X-ray examination was done that was safe for the fetus and the childbearing mother. Decision option was not used since the patient was in pain and could not understand much of the procedure that was explained.  Intuition helped in the decision-making in order to ensure safe and effective practice.

  19. Electron-ion-x-ray spectrometer system

    International Nuclear Information System (INIS)

    Southworth, S.H.; Deslattes, R.D.; MacDonald, M.A.

    1993-01-01

    The authors describe a spectrometer system developed for electron, ion, and x-ray spectroscopy of gas-phase atoms and molecules following inner-shell excitation by tunable synchrotron radiation. The spectrometer has been used on beamline X-24A at the National Synchrotron Light Source for excitation-dependent studies of Ar L-shell and K-shell photoexcitation and vacancy decay processes. The instrumentation and experimental methods are discussed, and examples are given of electron spectra and coincidence spectra between electrons and fluorescent x-rays

  20. An unprecedented process of peroxide ion formation and its localization in the crystal structure of strontium peroxy-hydroxyapatite Sr_1_0(PO_4)_6(O_2)_x(OH)_2_-_2_x

    International Nuclear Information System (INIS)

    Kazin, Pavel E.; Zykin, Mikhail A.; Dinnebier, Robert E.; Magdysyuk, Oxana V.; Jansen, Martin; Tretyakov, Yury D.

    2012-01-01

    Formation of strontium peroxy-hydroxyapatite solid solution Sr_1_0(PO_4)_6(O_2)_x(OH)_2_-_2_x was studied on annealing the hydroxyapatite in the temperature range 900-1350 C in oxygen, air, and argon atmosphere. The redox process was found to display unprecedented features: (i) the peroxide content increased with raising temperature, (ii) the peroxide content remained substantial even at a low oxygen pressure of 1.013 Pa, (iii) the peroxide content was extremely persistent, and even at a temperature of 1350 C in oxygen atmosphere the peroxide groups substituted more than two-third of the original hydroxide groups. Chemical processes consistent with these features are suggested. In the UV/Vis spectrum, an absorption peak at 300 nm was recorded, which was attributed to an electronic transition in the peroxide ion, since its intensity depended linearly on the peroxide content. In the Raman spectra, a weak band at 765-770 cm"-"1 was ascribed to symmetric stretching vibrations of O_2"2"-. The structures of the compounds were refined from powder X-ray diffraction data using the Rietveld method supported by a maximum entropy method (MEM) electron density calculation. The peroxide ions are localized in the center of the hexagonal channel. At high concentration they tend to order with the associated vacancies along the channels. As a consequence, the width of the channel sections varies, the PO_4 tetrahedra tilt, and the remote strontium atoms are displaced leading to changes in their coordination. Generally, the peroxide for hydroxide substitution manifests itself in the reduction of the overall channel diameter (and its volume), while the volume occupied by out-of-channel ions remains the same. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  1. Hard-x-ray phase-difference microscopy with a low-brilliance laboratory x-ray source

    International Nuclear Information System (INIS)

    Kuwabara, Hiroaki; Yashiro, Wataru; Harasse, Sebastien; Momose, Atsushi; Mizutani, Haruo

    2011-01-01

    We have developed a hard-X-ray phase-imaging microscopy method using a low-brilliance X-ray source. The microscope consists of a sample, a Fresnel zone plate, a transmission grating, and a source grating creating an array of mutually incoherent X-ray sources. The microscope generates an image exhibiting twin features of the sample with opposite signs separated by a distance, which is processed to generate a phase image. The method is quantitative even for non-weak-phase objects that are difficult to be quantitatively examined by the widely used Zernike phase-contrast microscopy, and it has potentially broad applications in the material and biological science fields. (author)

  2. Order-disorder-reorder process in thermally treated dolomite samples: a combined powder and single-crystal X-ray diffraction study

    Science.gov (United States)

    Zucchini, A.; Comodi, P.; Katerinopoulou, A.; Balic-Zunic, T.; McCammon, C.; Frondini, F.

    2012-04-01

    A combined powder and single-crystal X-ray diffraction analysis of dolomite [CaMg(CO3)2] heated to 1,200°C at 3 GPa was made to study the order-disorder-reorder process. The order/disorder transition is inferred to start below 1,100°C, and complete disorder is attained at approximately 1,200°C. Twinned crystals characterized by high internal order were found in samples annealed over 1,100°C, and their fraction was found to increase with temperature. Evidences of twinning domains combined with probable remaining disordered portions of the structure imply that reordering processes occur during the quench. Twin domains are hereby proposed as a witness to thermally induced intra-layer-type cation disordering.

  3. Fabrication and characterization of a 32 x 32 array digital Si-PIN X-ray detector for a single photon counting image sensor

    International Nuclear Information System (INIS)

    Seo, Jungho; Kim, Jinyoung; Lim, Hyunwoo; Park, Jingoo; Lee, Songjun; Kim, Bonghoe; Jeon, Sungchae; Huh, Young

    2010-01-01

    A Si-PIN X-ray detector for digital x-ray imaging with single photon counting capability has been fabricated and characterized. It consists of an array of 32 x 32 pixels with an area of 80 x 80 μm 2 . An extrinsic gettering process was performed to reduce the leakage current by removing the impurities and defects from the X-ray detector's Si substrate. Multiple guard-rings (MGRs) and metal filed plates (MFPs) techniques were adopted to reduce the leakage current and to improve the breakdown performance. The simulation verified that the breakdown voltage was improved with the MGRs and that the leakage current was significantly reduced with the MFPs. The electrical properties, such as the leakage current and the breakdown voltage, of the Si-PIN X-ray detector were characterized. The extrinsic gettering process played a significant role in reducing the leakage current, and a leakage current lower than 60 pA could be achieved at 100 V dc .

  4. Giant Faraday rotation in Bi(x)Ce(3-x)Fe5O12 epitaxial garnet films.

    Science.gov (United States)

    Chandra Sekhar, M; Singh, Mahi R; Basu, Shantanu; Pinnepalli, Sai

    2012-04-23

    Thin films of Bi(x)Ce(3-x)Fe(5)O(12) with x = 0.7 and 0.8 compositions were prepared by using pulsed laser deposition. We investigated the effects of processing parameters used to fabricate these films by measuring various physical properties such as X-ray diffraction, transmittance, magnetization and Faraday rotation. In this study, we propose a phase diagram which provides a suitable window for the deposition of Bi(x)Ce(3-x)Fe(5)O(12) epitaxial films. We have also observed a giant Faraday rotation of 1-1.10 degree/µm in our optimized films. The measured Faraday rotation value is 1.6 and 50 times larger than that of CeYIG and YIG respectively. A theoretical model has been proposed for Faraday rotation based on density matrix method and an excellent agreement between experiment and theory is found. © 2012 Optical Society of America

  5. Study of API 5L X70 steel corrosion processes when in contact with some Brazilian soils

    International Nuclear Information System (INIS)

    Jesus, Sergio Luis de

    2007-01-01

    Pipelines, fuel storage tanks and other metallic structures are in permanent contact and exposed to different types of soils, of horizons or layers, or of soil aggressiveness. This interaction may cause expressive damages to the environment and to the planned work. Contamination may occur due to leakage of stored products, splitting during transportation, accidents caused by pipelines without extensive maintenance. The result of these accidents could be, among others, some financial losses. In order to recognize the dynamic interactions between metallic surfaces and the environment it is crucial to have preventive actions and to develop better-applied materials. API steel 5L X70 has been used in structures of low and high pressure with high mechanical strength and corrosion and, even so, it is susceptible to etching corrosion since it is in contact with different environments from mangrove regions to industrial environments. The present case evaluated the role of 5L X70 API steel in contact with different soil horizons representative of the Brazilian soil. This investigation correlated chemical species with solute ions in soil solution, secondary and primary phase minerals besides physical and chemical characteristics as pH, electric conductivity, total dissolved solids, among others, to the results of corrosion resistance and ways of corrosion. The evaluation was carried out using x-ray diffractometry, scanning electron microscopy, total reflection x-ray fluorescence, fuel injection flow besides texture and gravimetric analyses to soil characterization and mineralogy, identification of corrosion products, soil solution analyses, evaluation of tested materials and classification of ways and types of corrosion. This was an attempt to integrate the data to a better understanding of the process involving reagents and products. The results showed that different soil horizons such as different types of analyzed soils produce specific etching in metallic structures

  6. Transport properties in amorphous U/sub x/-T1/sub -//sub x/ films (T = Fe, Ni, Gd, Tb, and Yb) (invited)

    International Nuclear Information System (INIS)

    Freitas, P.P.; Plaskett, T.S.; Moreira, J.M.; Amaral, V.S.

    1988-01-01

    We describe the competing magnetic, localization, and phonon effects on the transport properties of amorphous magnetic U/sub x/T/sub 1-//sub x/ films, with T = Fe, Ni, Gd, Tb, and Yb. Amorphous U/sub x/Fe/sub 1-//sub x/ films change from collinear to random ferromagnetism as x increases, and the temperature dependence of the resistivity denotes the competing effects of spin-flip and non-spin-flip exchange scattering processes. The resistivity has a minimum at T/sub f/ rising sharply below this temperature. The sign of the magnetic resistivity and the magnetoresistance indicates >0, while the anisotropic magnetoresistance indicates a local exchange gap. Amorphous U/sub x/Gd/sub 1-//sub x/ and a-U/sub x/Tb/sub 1-//sub x/ are, respectively, spin glasses and random anisotropy dominated systems. The resistivity increases smoothly through T/sub f/ and has a slight upturn at low temperatures that we associate with weak localization. The magnetoresistance is negative in both systems and the anisotropic magnetoresistance is null, although the applied field induces anisotropic behavior in the Tb containing films (asperomagnets). All samples show quadratic and positive field dependence of magnetoresistance well inside the paramagnetic regime, and a linear regime below T/sub f/. At low temperatures and in the a-U/sub x/Gd/sub 1-//sub x/ films, negative (H)/sup 1/2/ and H 2 regimes occur and are associated with weak localization processes dominated by the inelastic mean free path

  7. In situ X-ray diffraction study of crystallization process of GeSbTe thin films during heat treatment

    International Nuclear Information System (INIS)

    Kato, Naohiko; Konomi, Ichiro; Seno, Yoshiki; Motohiro, Tomoyoshi

    2005-01-01

    The crystallization processes of the Ge 2 Sb 2 Te 5 thin film used for PD and DVD-RAM were studied in its realistic optical disk film configurations for the first time by X-ray diffraction using an intense X-ray beam of a synchrotron orbital radiation facility (SPring-8) and in situ quick detection with a Position-Sensitive-Proportional-Counter. The dependence of the amorphous-to-fcc phase-change temperature T 1 on the rate of temperature elevation R et gave an activation energy E a : 0.93 eV much less than previously reported 2.2 eV obtained from a model sample 25-45 times thicker than in the real optical disks. The similar measurement on the Ge 4 Sb 1 Te 5 film whose large reflectance change attains the readability by CD-ROM drives gave E a : 1.13 eV with larger T 1 than Ge 2 Sb 2 Te 5 thin films at any R et implying a lower sensitivity in erasing as well as a better data stability of the phase-change disk

  8. X-ray diffraction analysis of aluminium containing Al8Fe2Si processed by equal channel angular pressing

    International Nuclear Information System (INIS)

    Korchef, Atef; Champion, Yannick; Njah, Nabil

    2007-01-01

    A 99.1% aluminium with initial grain size of ∼85 μm was deformed by equal channel angular (ECA) pressing. The sample undergoes an effective strain of 1.07 N by N passes through the die. The material contains a low volume fraction of Al 8 Fe 2 Si precipitates located essentially at the grain boundaries. The analysis of the X-ray diffraction peaks showed a significant broadening, which was related to grain refinement and lattice distortions. The crystallite size, calculated using the Halder-Wagner method, reached 225 nm after two passes and did not subsequently change. A decrease of the lattice parameter was also observed after ECA pressing. This is due to a partial dissolution of the precipitates. The microstructure was stable up an annealing of 200 deg. C due to the precipitates which delay the diffusion process. The annealing of the ECA pressed samples up to 400 deg. C leads to a decrease in the X-ray diffraction peaks broadening and an increase of the lattice parameter. This is due to grain growth

  9. X-ray images in the digital mode

    International Nuclear Information System (INIS)

    Buchmann, F.; Balter, S.

    1981-01-01

    In addition to computed tomography which presents actually the most important processing and transfer procedure of digital X-ray images, application of real time addition and substraction of X-ray images in a digital mode has found considerable interest. An estimation of the information contents of both digital and analog images is made in close relation to applications. As example of an image processing system on digital base a recently developed system for intravenous arteriography is described: the Philips-DVI. (orig.) [de

  10. Synthesis and Characterization of Nanocrystalline Ni50Al50-xMox (X=0-5 Intermetallic Compound During Mechanical Alloying Process

    Directory of Open Access Journals (Sweden)

    A. Khajesarvi

    2015-07-01

    Full Text Available In the present study, nanocrystalline Ni50Al50-xMox (X = 0, 0.5, 1, 2.5, 5 intermetallic compound was produced through mechanical alloying of nickel, aluminum, and molybdenum powders. AlNi compounds with good and attractive properties such as high melting point, high strength to weight ratio and high corrosion resistance especially at high temperatures have attracted the attention of many researchers. Powders produced from milling were analyzed using scanning electron microscopy (SEM and X-ray diffractometry (XRD. The results showed that intermetallic compound of NiAl formed at different stage of milling operation. It was concluded that at first disordered solid solution of (Ni,Al was formed then it converted into ordered intermetallic compound of NiAl. With increasing the atomic percent of molybdenum, average grain size decreased from 3 to 0.5 μm. Parameter lattice and lattice strain increased with increasing the atomic percent of molybdenum, while the crystal structure became finer up to 10 nm. Also, maximum microhardness was obtained for NiAl49Mo1 alloy.

  11. The Simbol-X Low Energy Detector

    International Nuclear Information System (INIS)

    Lechner, Peter

    2009-01-01

    For the Low Energy Detector of Simbol-X a new type of active pixel sensor based on the integrated amplifier DEPFET has been developed. This concept combines large area, scalable pixel size, low noise, and ultra-fast readout. Flight representative prototypes have been processed with a performance matching the Simbol-X specifications and demonstrating the technology readiness.

  12. The Simbol-X Low Energy Detector

    Science.gov (United States)

    Lechner, Peter

    2009-05-01

    For the Low Energy Detector of Simbol-X a new type of active pixel sensor based on the integrated amplifier DEPFET has been developed. This concept combines large area, scalable pixel size, low noise, and ultra-fast readout. Flight representative prototypes have been processed with a performance matching the Simbol-X specifications and demonstrating the technology readiness.

  13. A new data-processing approach to study particle motion using ultrafast X-ray tomography scanner: case study of gravitational mass flow

    Science.gov (United States)

    Waktola, Selam; Bieberle, Andre; Barthel, Frank; Bieberle, Martina; Hampel, Uwe; Grudzień, Krzysztof; Babout, Laurent

    2018-04-01

    In most industrial products, granular materials are often required to flow under gravity in various kinds of silo shapes and usually through an outlet in the bottom. There are several interrelated parameters which affect the flow, such as internal friction, bulk and packing density, hopper geometry, and material type. Due to the low-spatial resolution of electrical capacitance tomography or scanning speed limitation of standard X-ray CT systems, it is extremely challenging to measure the flow velocity and possible centrifugal effects of granular materials flow effectively. However, ROFEX (ROssendorf Fast Electron beam X-ray tomography) opens new avenues of granular flow investigation due to its very high temporal resolution. This paper aims to track particle movements and evaluate the local grain velocity during silo discharging process in the case of mass flow. The study has considered the use of the Seramis material, which can also serve as a type of tracer particles after impregnation, due to its porous nature. The presented novel image processing and analysis approach allows satisfyingly measuring individual particle velocities but also tracking their lateral movement and three-dimensional rotations.

  14. Growth of In x Ga1-x Sb alloy semiconductor at the International Space Station (ISS) and comparison with terrestrial experiments.

    Science.gov (United States)

    Inatomi, Y; Sakata, K; Arivanandhan, M; Rajesh, G; Nirmal Kumar, V; Koyama, T; Momose, Y; Ozawa, T; Okano, Y; Hayakawa, Y

    2015-01-01

    In x Ga 1- x Sb is an important material that has tunable properties in the infrared (IR) region and is suitable for IR-device applications. Since the quality of crystals relies on growth conditions, the growth process of alloy semiconductors can be examined better under microgravity (μG) conditions where convection is suppressed. To investigate the dissolution and growth process of In x Ga 1- x Sb alloy semiconductors via a sandwiched structure of GaSb(seed)/InSb/GaSb(feed) under normal and μG conditions. In x Ga 1- x Sb crystals were grown at the International Space Station (ISS) under μG conditions, and a similar experiment was conducted under terrestrial conditions (1G) using the vertical gradient freezing (VGF) method. The grown crystals were cut along the growth direction and its growth properties were studied. The indium composition and growth rate of grown crystals were calculated. The shape of the growth interface was nearly flat under μG, whereas under 1G, it was highly concave with the initial seed interface being nearly flat and having facets at the peripheries. The quality of the μG crystals was better than that of the 1G samples, as the etch pit density was low in the μG sample. The growth rate was higher under μG compared with 1G. Moreover, the growth started at the peripheries under 1G, whereas it started throughout the seed interface under μG. Kinetics played a dominant role under 1G. The suppressed convection under μG affected the dissolution and growth process of the In x Ga 1- x Sb alloy semiconductor.

  15. CdCl{sub 2} treatment related diffusion phenomena in Cd{sub 1−x}Zn{sub x}S/CdTe solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Kartopu, G., E-mail: giray.kartopu@glyndwr.ac.uk; Clayton, A. J.; Barrioz, V.; Lamb, D. A.; Irvine, S. J. C. [Centre for Solar Energy Research (CSER), Glyndŵr University, OpTIC, St. Asaph Business Park, St. Asaph LL17 0JD (United Kingdom); Taylor, A. A. [Physics Department, Durham University, Durham DH1 3LE (United Kingdom)

    2014-03-14

    Utilisation of wide bandgap Cd{sub 1−x}Zn{sub x}S alloys as an alternative to the CdS window layer is an attractive route to enhance the performance of CdTe thin film solar cells. For successful implementation, however, it is vital to control the composition and properties of Cd{sub 1−x}Zn{sub x}S through device fabrication processes involving the relatively high-temperature CdTe deposition and CdCl{sub 2} activation steps. In this study, cross-sectional scanning transmission electron microscopy and depth profiling methods were employed to investigate chemical and structural changes in CdTe/Cd{sub 1−x}Zn{sub x}S/CdS superstrate device structures deposited on an ITO/boro-aluminosilicate substrate. Comparison of three devices in different states of completion—fully processed (CdCl{sub 2} activated), annealed only (without CdCl{sub 2} activation), and a control (without CdCl{sub 2} activation or anneal)—revealed cation diffusion phenomena within the window layer, their effects closely coupled to the CdCl{sub 2} treatment. As a result, the initial Cd{sub 1−x}Zn{sub x}S/CdS bilayer structure was observed to unify into a single Cd{sub 1−x}Zn{sub x}S layer with an increased Cd/Zn atomic ratio; these changes defining the properties and performance of the Cd{sub 1−x}Zn{sub x}S/CdTe device.

  16. Direct observation of the crystal structure changes in the Mg{sub x}Zn{sub 1−x}O alloy system

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Seung Jo; Lee, Ji-Hyun; Kim, Chang-Yeon [Nano-Bio Electron Microscopy Research Group, Korea Basic Science Institute (KBSI), 169-148 Gwahak-ro, Yuseong-gu, Daejeon 305-806 (Korea, Republic of); Kim, Chang Hoi [Department of Nano Semiconductor Engineering, Korea Maritime and Ocean University, 727 Taejong-ro, Yeongdo-Gu, Busan 606-791 (Korea, Republic of); Shin, Jae Won [Nano-Bio Electron Microscopy Research Group, Korea Basic Science Institute (KBSI), 169-148 Gwahak-ro, Yuseong-gu, Daejeon 305-806 (Korea, Republic of); Center for Nanomaterials and Chemical Reactions, Institute for Basic Science (IBS), Daejeon 305-701 (Korea, Republic of); Kim, Hong Seung, E-mail: hongseung@hhu.ac.kr [Department of Nano Semiconductor Engineering, Korea Maritime and Ocean University, 727 Taejong-ro, Yeongdo-Gu, Busan 606-791 (Korea, Republic of); Kim, Jin-Gyu, E-mail: jjintta@kbsi.re.kr [Nano-Bio Electron Microscopy Research Group, Korea Basic Science Institute (KBSI), 169-148 Gwahak-ro, Yuseong-gu, Daejeon 305-806 (Korea, Republic of)

    2015-08-03

    We directly observed the crystal structure changes of the Mg{sub x}Zn{sub 1−x}O alloy thin film deposited on Si (111) substrates. Through the in situ heating transmission electron microscopy study, it was determined that the crystal structure changes did not occur up to at 400 °C, whereas the disappearance of the hexagonal structure was observed at 500 °C in the layer of nanosized grains. Additionally, the decreased intensity of the Zn L-edge was analyzed in the comparison of the core loss electron energy loss spectroscopy spectra of the Zn L-edge and the Mg K-edge obtained at room temperature and 500 °C. Based on these experimental results, the process of crystal structure changes could be explained by the evaporation of Zn atoms in the Mg{sub x}Zn{sub 1−x}O alloy system. This phenomenon is prominent in the improvement of the microstructure of the Mg{sub x}Zn{sub 1−x}O alloy thin film by controlling the thermal annealing temperature. - Highlights: • Mg{sub x}Zn{sub 1−x}O thin films coexisting with cubic and hexagonal structures were deposited. • Crystal structure changes of the thin films were directly observed at 500 °C. • The process of microstructure changes could be caused by the evaporation of Zn atoms.

  17. Techniques for synchronization of X-Ray pulses to the pump laser in an ultrafast X-Ray facility

    International Nuclear Information System (INIS)

    Corlett, J.N.; Doolittle, L.; Schoenlein, R.; Staples, J.; Wilcox, R.; Zholents, A.

    2003-01-01

    Accurate timing of ultrafast x-ray probe pulses emitted from a synchrotron radiation source with respect to the signal initiating a process in the sample under study is critical for the investigation of structural dynamics in the femtosecond regime. We describe schemes for achieving accurate timing of femtosecond x-ray synchrotron radiation pulses relative to a pump laser, where x-rays pulses of <100 fs duration are generated from the proposed LUX source based on a recirculating superconducting linac. We present a description of the timing signal generation and distribution systems to minimize timing jitter of the x-rays relative to the experimental lasers

  18. X-ray backlighting of two-wire Z-pinch plasma using X-pinch

    International Nuclear Information System (INIS)

    Tong, Zhao; Xiao-Bing, Zou; Ran, Zhang; Xin-Xin, Wang

    2010-01-01

    Two 50-μm Mo wires in parallel used as a Z-pinch load are electrically exploded with a pulsed current rising to 275 kA in 125 ns and their explosion processes are backlighted using an X-pinch as an x-ray source. The backlighting images show clearly the processes similar to those occurring in the initial stages of a cylindrical wire-array Z-pinch, including the electric explosion of single wires characterised by the dense wire cores surrounded by a low-density coronal plasma, the expansion of the exploding wire, the sausage instability (m = 0) in the coronal plasma around each wire, the motion of the coronal plasma as well as the wire core toward the current centroid, the formation of the precursor plasma column with a twist structure something like that of higher mode instability, especially the kink instability (m = 1). (fluids, plasmas and electric discharges)

  19. Utzon(x) 2013: Tetraleaf

    DEFF Research Database (Denmark)

    Andersson, Lasse; Foged, Isak Worre

    Why the (x) in Utzon? Among the possible ways to reconsider Utzon legacy, one can look at his strategies for variation and repetition in the light of the recent development of computer software, parametric modelling, computational techniques, digital fabrication and their application in architect......Why the (x) in Utzon? Among the possible ways to reconsider Utzon legacy, one can look at his strategies for variation and repetition in the light of the recent development of computer software, parametric modelling, computational techniques, digital fabrication and their application...... in architectural design and engineering. The Utzon(x) projects and summer school is a hands-on learning environment, where theoretical knowledge is coupled with physical and practical assignments related to specific design themes. During the two weeks of The Utzon(x) Summer School, twenty- five Danish...... and international students have worked on creating the project displayed in the Utzon Center court yard which has been unfolded as a working process and method in the exhibition space....

  20. A deep X-ray view of the bare AGN Ark 120. IV. XMM-Newton and NuSTAR spectra dominated by two temperature (warm, hot) Comptonization processes

    Science.gov (United States)

    Porquet, D.; Reeves, J. N.; Matt, G.; Marinucci, A.; Nardini, E.; Braito, V.; Lobban, A.; Ballantyne, D. R.; Boggs, S. E.; Christensen, F. E.; Dauser, T.; Farrah, D.; Garcia, J.; Hailey, C. J.; Harrison, F.; Stern, D.; Tortosa, A.; Ursini, F.; Zhang, W. W.

    2018-01-01

    Context. The physical characteristics of the material closest to supermassive black holes (SMBHs) are primarily studied through X-ray observations. However, the origins of the main X-ray components such as the soft X-ray excess, the Fe Kα line complex, and the hard X-ray excess are still hotly debated. This is particularly problematic for active galactic nuclei (AGN) showing a significant intrinsic absorption, either warm or neutral, which can severely distort the observed continuum. Therefore, AGN with no (or very weak) intrinsic absorption along the line of sight, so-called "bare AGN", are the best targets to directly probe matter very close to the SMBH. Aims: We perform an X-ray spectral analysis of the brightest and cleanest bare AGN known so far, Ark 120, in order to determine the process(es) at work in the vicinity of the SMBH. Methods: We present spectral analyses of data from an extensive campaign observing Ark 120 in X-rays with XMM-Newton (4 × 120 ks, 2014 March 18-24), and NuSTAR (65.5 ks, 2014 March 22). Results: During this very deep X-ray campaign, the source was caught in a high-flux state similar to the earlier 2003 XMM-Newton observation, and about twice as bright as the lower-flux observation in 2013. The spectral analysis confirms the "softer when brighter" behavior of Ark 120. The four XMM-Newton/pn spectra are characterized by the presence of a prominent soft X-ray excess and a significant Fe Kα complex. The continuum is very similar above about 3 keV, while significant variability is present for the soft X-ray excess. We find that relativistic reflection from a constant-density, flat accretion disk cannot simultaneously produce the soft excess, broad Fe Kα complex, and hard X-ray excess. Instead, Comptonization reproduces the broadband (0.3-79 keV) continuum well, together with a contribution from a mildly relativistic disk reflection spectrum. Conclusions: During this 2014 observational campaign, the soft X-ray spectrum of Ark 120 below 0

  1. Conference proceedings on X84 International Conference on X-ray and Inner-Shell Processes in Atoms, Molecules and Solids

    International Nuclear Information System (INIS)

    Meisel, A.; Finster, J.

    1984-01-01

    The proceedings contain 46 lectures and contributions presented at the 1984 conference. Topics of the conference were ion-atom collisions, inner-shell ionization phenomena, X-ray spectroscopy and electron spectroscopy

  2. Microeconomics of process control in semiconductor manufacturing

    Science.gov (United States)

    Monahan, Kevin M.

    2003-06-01

    Process window control enables accelerated design-rule shrinks for both logic and memory manufacturers, but simple microeconomic models that directly link the effects of process window control to maximum profitability are rare. In this work, we derive these links using a simplified model for the maximum rate of profit generated by the semiconductor manufacturing process. We show that the ability of process window control to achieve these economic objectives may be limited by variability in the larger manufacturing context, including measurement delays and process variation at the lot, wafer, x-wafer, x-field, and x-chip levels. We conclude that x-wafer and x-field CD control strategies will be critical enablers of density, performance and optimum profitability at the 90 and 65nm technology nodes. These analyses correlate well with actual factory data and often identify millions of dollars in potential incremental revenue and cost savings. As an example, we show that a scatterometry-based CD Process Window Monitor is an economically justified, enabling technology for the 65nm node.

  3. From Solidification Processing to Microstructure to Mechanical Properties: A Multi-scale X-ray Study of an Al-Cu Alloy Sample

    Science.gov (United States)

    Tourret, D.; Mertens, J. C. E.; Lieberman, E.; Imhoff, S. D.; Gibbs, J. W.; Henderson, K.; Fezzaa, K.; Deriy, A. L.; Sun, T.; Lebensohn, R. A.; Patterson, B. M.; Clarke, A. J.

    2017-11-01

    We follow an Al-12 at. pct Cu alloy sample from the liquid state to mechanical failure, using in situ X-ray radiography during directional solidification and tensile testing, as well as three-dimensional computed tomography of the microstructure before and after mechanical testing. The solidification processing stage is simulated with a multi-scale dendritic needle network model, and the micromechanical behavior of the solidified microstructure is simulated using voxelized tomography data and an elasto-viscoplastic fast Fourier transform model. This study demonstrates the feasibility of direct in situ monitoring of a metal alloy microstructure from the liquid processing stage up to its mechanical failure, supported by quantitative simulations of microstructure formation and its mechanical behavior.

  4. Thermonuclear process and accretion onto neutron star envelopes: x-ray burst and transient sources

    International Nuclear Information System (INIS)

    Starrfield, S.; Kenyon, S.; Sparks, W.M.; Truran, J.W.; Theoretical Division, Los Alamos National Laboratory)

    1982-01-01

    We have used a Lagrangian, fully implicit, one-dimensional, hydrodynamic computer code to investigate the evolution of thermonuclear runaways in the thick, accreted, hydrogen-rich envelopes of 1.0 M/sub sun/ neutron stars with radii of 10 km and 20 km. Our simulations produce outbursts which range in time scale from about 2000 seconds to longer than 1 day. Peak effective temperature was 3.3 x 10 7 K (kTapprox.2.91 keV), and peak luminosity was 2 x 10 5 L/sub sun/ for the 10 km study. The 20 km neutron star produced a peak effective temperature and luminosity of 5.3 x 10 6 K and 5.9 x 10 2 L/sub sun/, respectively. We also investigated the effects of changes in the rates of the 14 O(α,p) and 15 O(α,ν) reactions on the evolution. Hydrodynamic expansion on the 10 km neutron star produced a precursor lasting about 10 - 6 seconds

  5. Optimized fabrication protocols of microfluidic devices for X-ray analysis

    KAUST Repository

    Catalano, Rossella; Perozziello, Gerardo; Simone, Giuseppina; Candeloro, Patrizio; Gentile, Francesco T.; Coluccio, Maria Laura; Pardeo, Francesca; Burghammer, Manfred C.; Cuda, Giovanni; Riekel, Christian; Di Fabrizio, Enzo M.

    2014-01-01

    Microfluidics combined with X-ray scattering techniques allows probing conformational changes or assembly processes of biological materials. Our aim was to develop a highly X-ray transparent microfluidic cell for detecting small variations of X-ray

  6. Assessment by X-ray diffraction the process of bentonite organophilization using a different quaternary ammonium salts

    International Nuclear Information System (INIS)

    Silva, L.A. da; Rosario, J.A. do; Lima, R.B.; Milioli, C.C.; Gusatti, M.; Linhares, R.H.; Kuhnen, N.C.; Riella, H.G.

    2010-01-01

    The process was conducted in an organophilization Bentonite originated from the Company of Industrial Minerals of Mozambique Ltd. (Mimoc). The transformation of bentonite organophilic clay were performed in laboratory procedures that aim to mechanochemical exchange of Na + and Ca 2+ from the interlayer space of clay minerals by cations of quaternary ammonium salts. In this study we used two types of salts, which are: the cetyl trimethyl ammonium chloride and alkyl dimethyl benzyl ammonium chloride at different concentrations (30, 50, 80, 100 meq/100 g clay). The natural bentonite and organophilic clay samples were characterized by X-ray diffraction (XRD) to obtain the mineralogical constituents and analysis phases of the increase in interlayer distance confirming the incorporation of quaternary ammonium salts in the structure of clays. (author)

  7. Multichannel X-ray detectors

    Energy Technology Data Exchange (ETDEWEB)

    Khabakhpashev, A

    1980-10-01

    A typical design is discussed of multiwire proportional counters and their characteristic feature is explained, ie., the possibility of showing one or two coordinates of the X-ray quantum absorption site. The advantages of such instruments are listed, such as increased sensitivity of determination, the possibility of recording radiations of a different intensity, the possibility of on-line data processing and of the digital display of results. The fields of application include X-ray structural analysis in solid state physics, crystallography, molecular biology, astronomy, materials testing, and medicine.

  8. Modeling X-Ray Scattering Process and Applications of the Scattering Model

    Science.gov (United States)

    Al-Jundi, Taher Lutfi

    1995-01-01

    Computer modeling of nondestructive inspections with x-rays is proving to be a very useful tool for enhancing the performance of these techniques. Two x-ray based inspection techniques are considered in this study. The first is "Radiographic Inspection", where an existing simulation model has been improved to account for scattered radiation effects. The second technique is "Inspection with Compton backscattering", where a new simulation model has been developed. The effect of scattered radiation on a simulated radiographic image can be insignificant, equally important, or more important than the effect of the uncollided flux. Techniques to account for the scattered radiation effects include Monte Carlo techniques, and solving the particle transport equation for photons. However, these two techniques although accurate, are computationally expensive and hence inappropriate for use in computer simulation of radiography. A less accurate approach but computationally efficient is the principle of buildup factors. Traditionally, buildup factors are defined for monoenergetic photons of energies typical of a nuclear reactor. In this work I have expanded the definition of buildup factors to include a bremsstrahlung spectrum of photons with energies typically used in radiography (keV's instead of MeV's). This expansion of the definition relies on an intensive experimental work to measure buildup factors for a white spectrum of x-rays. I have also developed a monte carlo code to reproduce the measured buildup factors. The code was then converted to a parallel code and distributed on a network of workstations to reduce the execution time. The second inspection technique is based on Compton backscattering, where photons are scattered at large angles, more than 90 degrees. The importance of this technique arises when the inspected object is very large, or when access is limited to only one side of the specimen. The downside of detecting photons from backscattering is the low

  9. Photoproduction of long-lived holes and electronic processes in intrinsic electric fields seen through photoinduced absorption and dichroism in Ca sub 3 Ga sub 2 sub - sub x Mn sub x Ge sub 3 O sub 1 sub 2 garnets

    CERN Document Server

    Eremenko, V V; Kachur, I S; Piryatinskaya, V G; Ratner, A M; Kosmyna, M B; Nazarenko, B P; Puzikov, V M

    2003-01-01

    Long-lived photoinduced absorption and dichroism in the Ca sub 3 Ga sub 2 sub - sub x Mn sub x Ge sub 3 O sub 1 sub 2 garnets with x < 0.06 were examined versus temperature and pumping intensity. Unusual features of the kinetics of photoinduced phenomena are indicative of the underlying electronic processes. The comparison with the case of Ca sub 3 Mn sub 2 Ge sub 3 O sub 1 sub 2 , explored earlier by the authors, permits one to finally establish the main common mechanisms of photoinduced absorption and dichroism caused by random electric fields of photoproduced charges (hole polarons). The rate of their diffusion and relaxation through recombination is strongly influenced by the same fields, whose large statistical straggling is responsible for a broad continuous set of relaxation components (observed in the relaxation time range from 1 to about 1000 min). For Ca sub 3 Ga sub 2 sub - sub x Mn sub x Ge sub 3 O sub 1 sub 2 , the time and temperature dependences of photoinduced absorption and dichroism bear ...

  10. Penentuan Rute Patroli Sekuriti Optimal Dengan Menggunakan Metode Nearest Neighbour Dan Insertion (Studi Kasus : South Processing Unit PT. X

    Directory of Open Access Journals (Sweden)

    Fuaddillah Fuaddillah

    2017-03-01

    Full Text Available South Processing Unit (SPU merupakan salah satu lapangan migas di PT. X dengan estimasi harian produksi gas sekitar 450 gas (MMscf/d dan 5000 kondensat (BOPD. Gas dan kondesat yang terpisah dari masing-masing sumur produksi akan dikumpulkan ke dalam satu stasiun pengumpul yang disebut Gathering and Testing Satellite (GTS. Karena statusnya sebagai objek vital nasional, melakukan patroli sekuriti di laut antara GTS yang satu dengan GTS lainnya wajib dilakukan. Proses patroli sekuriti dengan seatruck pada kawasan SPU PT. X masih menggunakan intuisi dari supir seatruck dimana rute yang dipilih adalah rute yang dirasa lebih dekat, lebih nyaman dilalui, dan lebih familiar dengan pengetahuan supir sendiri sehingga menghasilkan total jarak tempuh yang lebih jauh. Penelitian ini bertujuan untuk menerapkan dan membandingkan metode intuitif yang dilakukan oleh supir seatruck dengan metode nearest neighbour dan metode insertion dalam permasalahan penentuan rute patroli sekuriti yang optimal di PT. X pada lokasi SPU. Hasil penelitian menunjukkan bahwa total jarak tempuh dengan menggunakan metode intuitif yang telah diterapkan oleh supir seatruck adalah 72,76 km. Sedangkan, total jarak tempuh yang didapatkan dari menggunakan metode nearest neighbour yaitu 67,67 km dengan persentase penghematan jarak sebesar 6,9%. Dengan metode insertion, didapatkan total jarak tempuh sebesar 61,40 km, dengan persentase penghematan jarak sebesar 15,6% dibandingkan dengan metode intuitif supir seatruck.

  11. Cone-beam x-ray luminescence computed tomography based on x-ray absorption dosage

    Science.gov (United States)

    Liu, Tianshuai; Rong, Junyan; Gao, Peng; Zhang, Wenli; Liu, Wenlei; Zhang, Yuanke; Lu, Hongbing

    2018-02-01

    With the advances of x-ray excitable nanophosphors, x-ray luminescence computed tomography (XLCT) has become a promising hybrid imaging modality. In particular, a cone-beam XLCT (CB-XLCT) system has demonstrated its potential in in vivo imaging with the advantage of fast imaging speed over other XLCT systems. Currently, the imaging models of most XLCT systems assume that nanophosphors emit light based on the intensity distribution of x-ray within the object, not completely reflecting the nature of the x-ray excitation process. To improve the imaging quality of CB-XLCT, an imaging model that adopts an excitation model of nanophosphors based on x-ray absorption dosage is proposed in this study. To solve the ill-posed inverse problem, a reconstruction algorithm that combines the adaptive Tikhonov regularization method with the imaging model is implemented for CB-XLCT reconstruction. Numerical simulations and phantom experiments indicate that compared with the traditional forward model based on x-ray intensity, the proposed dose-based model could improve the image quality of CB-XLCT significantly in terms of target shape, localization accuracy, and image contrast. In addition, the proposed model behaves better in distinguishing closer targets, demonstrating its advantage in improving spatial resolution.

  12. Surface characterization of selected polymer thin films by total-reflection x-ray fluorescence spectroscopy and x-ray reflectivity

    International Nuclear Information System (INIS)

    Innis, Vallerie Ann A.

    2006-01-01

    Development of available x-ray characterizations tools for grazing incidence techniques was done to be able to probe nano-size thin films. Alignment of a Philips x-ray powder diffractometer was improved to let it perform as an x-ray reflectometer. X-ray reflectometry was coupled with total-reflection x-ray fluorescence spectroscopy. Evaluation of the performance of this grazing incidence techniques was done by preparing polymer thin films of carboxymethylcellulose, carrageenan and polyvinylpyrrolidone (PVP). The thickness of the films were varied by varying the process parameters such as concentration, spin speed and spin time. Angle-dispersive total-reflection x-ray fluorescence spectroscopy profiles of three films showed film formation only in carrageenan and PVP. For both carrageenan and PVP, an increase in concentration yielded a corresponding increase in intensity of the fluorescent or scattered peaks. XRR profiles of carrageenan thin films yielded a mean value for the critical angle close to quartz substrate. Thickness measurements of the prepared carrageenan thin films showed that concentration was the main determinant for final film thickness over the other process parameters. Sulfur fluorescent intensity derived from the TXRF measurement showed a linear relationship with the measured thickness by XRR. For PVP, measured critical angle is lower than quartz. Poor adhesion of the polymer onto the substrate yielded a limited number of thickness measurements made from the XRR profiles. (Author)

  13. Thermal stability of Ni-Pt-Ta alloy silicides on epi-Si{sub 1-x}C{sub x}

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Jung-Ho; Chang, Hyun-Jin [Department of Ceramic Engineering, Yonsei University, Seoul 120-749 (Korea, Republic of); Min, Byoung-Gi [Department of Ceramic Engineering, Yonsei University, Seoul 120-749 (Korea, Republic of); Jusung Engineering Co., Ltd., 49, Neungpyeong-ri, Opo-eup, Gwangju-Si, Kyunggi-do 464-892 (Korea, Republic of); Ko, Dae-Hong [Department of Ceramic Engineering, Yonsei University, Seoul 120-749 (Korea, Republic of)], E-mail: dhko@yonsei.ac.kr; Cho, Mann-Ho [Institute of Physics and Applied Physics, Yonsei University, Seoul 120-749 (Korea, Republic of); Sohn, Hyunchul [Department of Ceramic Engineering, Yonsei University, Seoul 120-749 (Korea, Republic of); Lee, Tae-Wan [Jusung Engineering Co., Ltd., 49, Neungpyeong-ri, Opo-eup, Gwangju-Si, Kyunggi-do 464-892 (Korea, Republic of)

    2008-12-05

    We investigated the silicide formation in Ni/epi-Si{sub 1-x}C{sub x} systems. Ni-Pt and Ni-Pt-Ta films were deposited on epi-Si{sub 1-x}C{sub x}/Si substrates by DC magnetron sputtering and processed at various temperatures. The sheet resistance of the silicide from the Ni alloy/epi-Si{sub 1-x}C{sub x} systems was maintained at low values compared to that from Ni/Si systems. By TEM and EDS analyses, we confirmed the presence of a Pt alloy layer at the top of the Ni-silicide layer. The stability of the silicide layer in the Ni alloy/epi-Si{sub 1-x}C{sub x} system is explained by not only the Pt rich layer on the top of the Ni-silicide layer, but also by the presence of a small amount of Pt in the Ni-silicide layer or at the grain boundaries. And both the thermal stability and the morphology of silicide were greatly improved by the addition of Ta in Ni-Pt films.

  14. Synthesis, Characterization, and Gas-Sensing Properties of Mesoporous Nanocrystalline Sn(x)Ti(1-x)O2.

    Science.gov (United States)

    Zhong, Cheng; Lin, Zhidong; Guo, Fei; Wang, Xuehua

    2015-06-01

    A nanocomposite mesoporous material composed by SnO2 and TiO2 with the size of -5-9 nm were prepared via a facile wet-chemical approach combining with an annealing process. The microstructure of obtained Sn(x)Ti(1-x)O2 powders were characterized by X-ray diffraction, X-ray Photo-electronic Spectroscopy, scanning electron microscope, transmission electron microscope and nitrogen adsorption-desorption experiment. The gas sensing performances to several gases of the mesoporous material were studied. The sensors of Sn(x)Ti(1-x)O2 (ST10, with 9.1% Ti) exhibited very high responses to volatile organic compounds at 160 degrees C. The order of the responses to volatile gases based on ST10 was ethanol > formaldehyde > acetone > toluene > benzene > methane. Sensor based on ST10 displays a highest sensitivity to hydrogen at 200 degrees C. Sensor responses to H2 at 200 degrees C have been measured and analyzed in a wide concentration range from 5 to 2000 ppm. The solid solution Sn(x)Ti(1-x)O2 can be served as a potential gas-sensing material for a broad range of future sensor applications.

  15. Rapid data processing for ultrafast X-ray computed tomography using scalable and modular CUDA based pipelines

    Science.gov (United States)

    Frust, Tobias; Wagner, Michael; Stephan, Jan; Juckeland, Guido; Bieberle, André

    2017-10-01

    Ultrafast X-ray tomography is an advanced imaging technique for the study of dynamic processes basing on the principles of electron beam scanning. A typical application case for this technique is e.g. the study of multiphase flows, that is, flows of mixtures of substances such as gas-liquidflows in pipelines or chemical reactors. At Helmholtz-Zentrum Dresden-Rossendorf (HZDR) a number of such tomography scanners are operated. Currently, there are two main points limiting their application in some fields. First, after each CT scan sequence the data of the radiation detector must be downloaded from the scanner to a data processing machine. Second, the current data processing is comparably time-consuming compared to the CT scan sequence interval. To enable online observations or use this technique to control actuators in real-time, a modular and scalable data processing tool has been developed, consisting of user-definable stages working independently together in a so called data processing pipeline, that keeps up with the CT scanner's maximal frame rate of up to 8 kHz. The newly developed data processing stages are freely programmable and combinable. In order to achieve the highest processing performance all relevant data processing steps, which are required for a standard slice image reconstruction, were individually implemented in separate stages using Graphics Processing Units (GPUs) and NVIDIA's CUDA programming language. Data processing performance tests on different high-end GPUs (Tesla K20c, GeForce GTX 1080, Tesla P100) showed excellent performance. Program Files doi:http://dx.doi.org/10.17632/65sx747rvm.1 Licensing provisions: LGPLv3 Programming language: C++/CUDA Supplementary material: Test data set, used for the performance analysis. Nature of problem: Ultrafast computed tomography is performed with a scan rate of up to 8 kHz. To obtain cross-sectional images from projection data computer-based image reconstruction algorithms must be applied. The

  16. DISTRIBUTION MANAGEMENT IN COMPANY X

    OpenAIRE

    Agnieszka Wójcik-Mazur; Karina Wieczorek

    2012-01-01

    The subject of this publication is the problem of distribution management, exemplified by Company X. The process has been defined by analysing the conditions necessary to satisfy prospects’ needs and create the market position of a business entity. The paper focuses on the basic features of distribution system and the character of distribution channels.The assessment of distribution management has been illustrated with an example of Company X. The subjects of interest are: the dynamics of ord...

  17. In situ synchrotron x-ray characterization of microstructure formation in solidification processing of Al-based metallic alloys

    International Nuclear Information System (INIS)

    Billia, Bernard; Nguyen-Thi, Henri; Mangelinck-Noel, Nathalie

    2010-01-01

    The microstructure formed during the solidification step has a major influence on the properties of materials processed by major techniques (casting, welding ...). In situ and real-time characterization by synchrotron X-ray imaging is the method of choice to unveil the dynamical formation of the solidification microstructure in metallic alloys, and thus provide precise data for the critical validation of the theoretical predictions that is needed for sound advancement of modeling and numerical simulation. After a description of the experimental procedure used at the European Synchrotron Radiation Facility (ESRF), dynamical phenomena in the formation of the grain structure and dendritic or equiaxed solidification microstructure in Al-based alloys are presented. Beyond fluid flow interaction, earth gravity induces stresses, deformation and fragmentation in the dendritic mush. Settling of dendrite arms and equiaxed grains thus occurs, in particular in the columnar to equiaxed transition. Other types of stresses and strains are caused by the mere formation of the solidification microstructure itself. In white-beam X-ray topography, stresses and strains are manifested by specific contrasts and breaking of the Laue images into several pieces. Finally, quantitative analysis of the grey level in radiographs enables the analysis of solute segregation, which noticeably results in solutal poisoning of growth when equiaxed grains are interacting. (author)

  18. The comparative study of contents of zinc and lead in ore samples of Namtu-Bawdwin Mine by wet analysis, X-ray fluorescence and X-ray diffraction methods

    Energy Technology Data Exchange (ETDEWEB)

    Kyaw-Soe,

    1990-05-01

    Lead-zinc ores taken from Namtu-Bawdwin area had been analyzed by wet processes in the Department of Chemistry, 1984. These ore samples have been analyzed by energy dispersive X-ray fluorescence method in the Department of Physics and X-ray diffraction method is also used to determine elements of lead and zinc compounds in these ore samples in the University`s Research Centre. In brief, we study comparatively the contents of lead and zinc and their compounds using the methods of wet processes, X-ray fluorescence and X-ray diffraction. (author).

  19. Young Stellar Objects from Soft to Hard X-rays

    Science.gov (United States)

    Güdel, Manuel

    2009-05-01

    Magnetically active stars are the sites of efficient particle acceleration and plasma heating, processes that have been studied in detail in the solar corona. Investigation of such processes in young stellar objects is much more challenging due to various absorption processes. There is, however, evidence for violent magnetic energy release in very young stellar objects. The impact on young stellar environments (e.g., circumstellar disk heating and ionization, operation of chemical networks, photoevaporation) may be substantial. Hard X-ray devices like those carried on Simbol-X will establish a basis for detailed studies of these processes.

  20. X-ray diagnostics for laser matter interaction experiments; Diagnostics X pour les experiences d'interaction laser-matiere

    Energy Technology Data Exchange (ETDEWEB)

    Troussel, Ph

    2000-07-01

    Advances in the field of laser-driven inertially confined thermonuclear fusion research since the early 1990's are reviewed. It covers the experimental techniques used to study the interaction of laser radiation with matter and high density plasma. A high performance instrumentation (diagnostics) for observation of X radiation (from a few eV to a few keV) will be required to understand the physical processes involved in the interaction. This paper is a three-part: first part, describes diagnostics metrology realized around different X-ray sources (synchrotron, laser plasma...); a second part, synthesizes theoretical and experimental X-ray optics studies and show the interest for direct applications as X-ray spectroscopy and X-ray imaging around laser-produced plasma; a third part, is a review of high resolution X-ray imaging, performances of these optical system were summarized. (author)

  1. 73.7 Tb/s (96x3x256-Gb/s) mode-division-multiplexed DP-16QAM transmission with inline MM-EDFA

    NARCIS (Netherlands)

    Sleiffer, V.A.J.M.; Jung, Y.; Veljanovski, V.; Uden, van R.G.H.; Kuschnerov, M.; Kang, Q.; Grüner-Nielsen, L.; Sun, Y.; Richardson, D.J.; Alam, S.U.; Poletti, F.; Sahu, J.K.; Dhar, A.; Chen, H.; Inan, B.; Koonen, A.M.J.; Corbett, B.; Winfield, R.; Ellis, A.D.; Waardt, de H.

    2012-01-01

    We show transmission of a 73.7 Tb/s (96x3x256-Gb/s) DP-16QAM mode-division- multiplexed signal over 119km of few-mode fiber with inline multi-mode EDFA, using 6x6 MIMO digital signal processing. The total demonstrated net capacity is 57.6 Tb/s (SE 12 bits/s/Hz).

  2. X-ray total reflection mirrors for coherent illumination

    CERN Document Server

    Ishikawa, T; Yabashi, M; Souvorov, A; Yamauchi, K; Yamamura, K; Mimura, H; Saito, A; Mori, Y

    2002-01-01

    X-ray mirrors for coherent illumination demand much higher surface quality than is achievable with the conventional polishing techniques. Plasma chemical vaporization machining (CVM) and elastic emission machining (EEM) have been applied for x-ray mirror manufacturing. Figure error of a flat silicon single crystal mirrors made with CVM+EEM process was reduced to 2.0 nm peak-to-valley and 0.2 nm RMS. The machining process was also applied to make elliptical mirrors. One-dimensional focusing with a single elliptical mirror showed diffraction-limited properties with the focal width of 200 nm. Two-dimensional focusing with Kirkpatric-Baez configuration gave a focal spot size of 200 nm x 200 nm. (author)

  3. Design and fabrication of soft x-ray mirrors

    Energy Technology Data Exchange (ETDEWEB)

    Kawata, Masaru; Sasai, Hiroyuki; Sano, Kazuo [Shimadzu Corp., Production Engineering Laboratory, Kyoto (Japan)

    2000-03-01

    Soft x-ray photoelectron spectroscopic technology is important for measuring the chemical status of material surface in the LSI manufacturing process. We report on non-spherical mirrors focusing laser-induced plasma soft x-ray to fine sample surface. We designed toric and ellipsoidal mirror as soft x-ray condensing means, simulated focusing image, manufactured mirror surface on fused quartz substrate, and measured form accuracy. (author)

  4. Underground muons from Cygnus X-3

    International Nuclear Information System (INIS)

    Price, L.E.

    1985-01-01

    Underground detectors, intended for searches for nucleon decay and other rare processes, have recently begun searching for evidence of astrophysical sources, particularly Cygnus X-3, in the cosmic ray muons they record. Some evidence for signals from Cygnus X-3 has been reported. The underground observations are reported here in the context of previous (surface) observations of the source at high energies. 25 refs., 8 figs

  5. X-ray diagnosis of rib chondrosarcoma

    International Nuclear Information System (INIS)

    Smakova, M.S.

    1982-01-01

    A study was made on X-ray images of 24 patients, suffering from rib chondrosarcoma with relapses. X-ray symptoms of rib chondrosarcoma, depending on process localization were improved. Chondrosarcoma of rib cartilage is characterized by soft-tissue component with calcareous inclusions or without them. Chondrosarcoma of rib bone is characterized by destruction and soft-tissue component. Chondrosarcoma relapses were localized in soft tissues

  6. Attentional Set-Shifting in Fragile X Syndrome

    Science.gov (United States)

    Van der Molen, M. J. W.; Van der Molen, M. W.; Ridderinkhof, K. R.; Hamel, B. C. J.; Curfs, L. M. G.; Ramakers, G. J. A.

    2012-01-01

    The ability to flexibly adapt to the changing demands of the environment is often reported as a core deficit in fragile X syndrome (FXS). However, the cognitive processes that determine this attentional set-shifting deficit remain elusive. The present study investigated attentional set-shifting ability in fragile X syndrome males with the…

  7. Solar flares: radio and X-ray signatures of magnetic reconnection processes

    Czech Academy of Sciences Publication Activity Database

    Karlický, Marian

    2014-01-01

    Roč. 14, č. 7 (2014), s. 753-772 ISSN 1674-4527 R&D Projects: GA ČR GAP209/12/0103 Institutional support: RVO:67985815 Keywords : Sun: flares * Sun: radio radiation * Sun: X- rays Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 1.640, year: 2014

  8. Markov Jump Processes Approximating a Non-Symmetric Generalized Diffusion

    International Nuclear Information System (INIS)

    Limić, Nedžad

    2011-01-01

    Consider a non-symmetric generalized diffusion X(⋅) in ℝ d determined by the differential operator A(x) = -Σ ij ∂ i a ij (x)∂ j + Σ i b i (x)∂ i . In this paper the diffusion process is approximated by Markov jump processes X n (⋅), in homogeneous and isotropic grids G n ⊂ℝ d , which converge in distribution in the Skorokhod space D([0,∞),ℝ d ) to the diffusion X(⋅). The generators of X n (⋅) are constructed explicitly. Due to the homogeneity and isotropy of grids, the proposed method for d≥3 can be applied to processes for which the diffusion tensor {a ij (x)} 11 dd fulfills an additional condition. The proposed construction offers a simple method for simulation of sample paths of non-symmetric generalized diffusion. Simulations are carried out in terms of jump processes X n (⋅). For piece-wise constant functions a ij on ℝ d and piece-wise continuous functions a ij on ℝ 2 the construction and principal algorithm are described enabling an easy implementation into a computer code.

  9. A non-destructive synchrotron X-ray study of the metallurgy and manufacturing processes of Eastern and Western astrolabes in the Adler Planetarium collection

    Science.gov (United States)

    Newbury, Brian Dale

    The astrolabe collection of the Adler Planetarium and History of Astronomy Museum, Chicago, IL, was examined using non-destructive synchrotron based high-energy X-ray techniques including diffraction, fluorescence, and radiography to determine the metallurgy, microstructure, and metal forming processes used in astrolabe construction. All high-energy X-ray measurements were performed at the Advanced Photon Source (APS) synchrotron of Argonne National Laboratory, Argonne, IL. Astrolabes from the collection were selected to represent all major astrolabe production centers possible and time periods. It was found that all European astrolabes were manufactured of traditional cementation brass by hand worked metal forming processes consistent with technology in the literature. Of the Islamic astrolabes examined, all seven from Lahore in current-day Pakistan exhibited advanced brass alloys not typical of alloys discussed in the literature. It was found that these alloys were selected for their specific hot working properties, allowing the Lahore metalworkers to more efficiently make brass sheet from which to make astrolabe components. In addition, the alloy required a fundamental change in the brass foundry process, indicating advanced Zn metal production techniques. It was found that analysis by high energy X-rays from the APS was essential to produce data on the chemistry and microstructure from the interior of the astrolabe components in a non-destructive manner. Many astrolabe components had undergone surface dezincification due to heavy annealing during manufacturing, causing the Zn composition measured by the surface sensitive fluorescence technique to be lower than the true bulk alloy Zn composition. This would have been impossible to quantify non-destructively without the high-energy diffraction capability of the APS. The results of this study have proven the effectiveness of the synchrotron as a viable non-destructive analysis technique for examining cultural

  10. Investigation of the yield process by deformation luminescence of X-ray irradiated KCl:Ca2+

    International Nuclear Information System (INIS)

    Nakamura, S.; Ida, K.; Ohgaku, T.

    2011-01-01

    It is found that deformation luminescence gives us information about the microscopic yield process of X-ray irradiated KCl:Ca 2+ . The stress-strain curve has a macroscopic yield point. But we find that luminescence appears to start before the macroscopic yield. This means that dislocation begin to move before the macroscopic yield because deformation luminescence is attributed to radiation-induced dislocation motion. The beginning of luminescence is considered to be the microscopic yield. Investigating the dependence of microscopic yield stress on strain rate and impurity concentration gives us additional information. The activation volume obtained from the dependence of microscopic yield stress on strain rate is comparable to the value estimated from the concentration of impurity. Then the dislocation starts to move overcoming impurity-vacancy dipoles as obstacles to dislocation motion. The dislocation density starts to increase at the microscopic yield point and then sharply increases to the macroscopic yield.

  11. MgxZn1-xO(0≤x<0.2) nanowire arrays on sapphire grown by high-pressure pulsed-laser deposition

    International Nuclear Information System (INIS)

    Lorenz, M.; Kaidashev, E.M.; Rahm, A.; Nobis, Th.; Lenzner, J.; Wagner, G.; Spemann, D.; Hochmuth, H.; Grundmann, M.

    2005-01-01

    Mg x Zn 1-x O nanowires with Mg-content x from 0 to 0.2 have been grown by high-pressure pulsed-laser deposition (PLD) on gold-covered sapphire single crystals. The PLD process allows for a unique wide-range control of morphology, diameter, and composition of the Mg x Zn 1-x O nanowires. The diameter of single ZnO wires could be varied between about 50 and 3000 nm, and the Mg content x of Mg x Zn 1-x O wire arrays was controlled via the PLD gas pressure. The microscopic homogeneity of Mg content is displayed by cathodoluminescence (CL) imaging of the excitonic peak energy. The fluctuation of CL peak energy between individual wires is about an order of magnitude smaller than the alloy broadening

  12. In situ X-ray diffraction study of crystallization process of GeSbTe thin films during heat treatment

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Naohiko [Toyota Central R and D Labs., Inc., Nagakute, Aichi 480-1192 (Japan)]. E-mail: e0957@mosk.tytlabs.co.jp; Konomi, Ichiro [Toyota Central R and D Labs., Inc., Nagakute, Aichi 480-1192 (Japan); Seno, Yoshiki [Toyota Central R and D Labs., Inc., Nagakute, Aichi 480-1192 (Japan); Motohiro, Tomoyoshi [Toyota Central R and D Labs., Inc., Nagakute, Aichi 480-1192 (Japan)

    2005-05-15

    The crystallization processes of the Ge{sub 2}Sb{sub 2}Te{sub 5} thin film used for PD and DVD-RAM were studied in its realistic optical disk film configurations for the first time by X-ray diffraction using an intense X-ray beam of a synchrotron orbital radiation facility (SPring-8) and in situ quick detection with a Position-Sensitive-Proportional-Counter. The dependence of the amorphous-to-fcc phase-change temperature T{sub 1} on the rate of temperature elevation R{sub et} gave an activation energy E{sub a}: 0.93 eV much less than previously reported 2.2 eV obtained from a model sample 25-45 times thicker than in the real optical disks. The similar measurement on the Ge{sub 4}Sb{sub 1}Te{sub 5} film whose large reflectance change attains the readability by CD-ROM drives gave E{sub a}: 1.13 eV with larger T{sub 1} than Ge{sub 2}Sb{sub 2}Te{sub 5} thin films at any R{sub et} implying a lower sensitivity in erasing as well as a better data stability of the phase-change disk.

  13. In situ study of the growth and degradation processes in tetragonal lysozyme crystals on a silicon substrate by high-resolution X-ray diffractometry

    Science.gov (United States)

    Kovalchuk, M. V.; Prosekov, P. A.; Marchenkova, M. A.; Blagov, A. E.; D'yakova, Yu. A.; Tereshchenko, E. Yu.; Pisarevskii, Yu. V.; Kondratev, O. A.

    2014-09-01

    The results of an in situ study of the growth of tetragonal lysozyme crystals by high-resolution X-ray diffractometry are considered. The crystals are grown by the sitting-drop method on crystalline silicon substrates of different types: both on smooth substrates and substrates with artificial surface-relief structures using graphoepitaxy. The crystals are grown in a special hermetically closed crystallization cell, which enables one to obtain images with an optical microscope and perform in situ X-ray diffraction studies in the course of crystal growth. Measurements for lysozyme crystals were carried out in different stages of the crystallization process, including crystal nucleation and growth, developed crystals, the degradation of the crystal structure, and complete destruction.

  14. Enhancement of discharge performance of Li/CF x cell by thermal treatment of CF x cathode material

    Science.gov (United States)

    Zhang, Sheng S.; Foster, Donald; Read, Jeffrey

    In this work we demonstrate that the thermal treatment of CF x cathode material just below the decomposition temperature can enhance discharge performance of Li/CF x cells. The performance enhancement becomes more effective when heating a mixture of CF x and citric acid (CA) since CA serves as an extra carbon source. Discharge experiments show that the thermal treatment not only reduces initial voltage delay, but also raises discharge voltage. Whereas the measurement of powder impedance indicates the thermal treatment does not increase electronic conductivity of CF x material. Based on these facts, we propose that the thermal treatment results in a limited decomposition of CF x, which yields a subfluorinated carbon (CF x- δ), instead of a highly conductive carbon. In the case of CF x/AC mixture, the AC provides extra carbon that reacts with F 2 and fluorocarbon radicals generated by the thermal decomposition of CF x to form subfluorinated carbon. The process of thermal treatment is studied by thermogravimetric analysis and X-ray diffraction, and the effect of treatment conditions such as heating temperature, heating time and CF x/CA ratio on the discharge performance of CF x cathode is discussed. As an example, a Li/CF x cell using CF x treated with CA at 500 °C under nitrogen for 2 h achieved theretical specific capacity when being discharged at C/5. Impedance analysis indicates that the enhanced performance is attributed to a significant reduction in the cell reaction resistance.

  15. Study of x-ray CCD image sensor and application

    Science.gov (United States)

    Wang, Shuyun; Li, Tianze

    2008-12-01

    In this paper, we expounded the composing, specialty, parameter, its working process, key techniques and methods for charge coupled devices (CCD) twice value treatment. Disposal process for CCD video signal quantification was expatiated; X-ray image intensifier's constitutes, function of constitutes, coupling technique of X-ray image intensifier and CCD were analyzed. We analyzed two effective methods to reduce the harm to human beings when X-ray was used in the medical image. One was to reduce X-ray's radiation and adopt to intensify the image penetrated by X-ray to gain the same effect. The other was to use the image sensor to transfer the images to the safe area for observation. On this base, a new method was presented that CCD image sensor and X-ray image intensifier were combined organically. A practical medical X-ray photo electricity system was designed which can be used in the records and time of the human's penetrating images. The system was mainly made up with the medical X-ray, X-ray image intensifier, CCD vidicon with high resolution, image processor, display and so on. Its characteristics are: change the invisible X-ray into the visible light image; output the vivid images; short image recording time etc. At the same time we analyzed the main aspects which affect the system's resolution. Medical photo electricity system using X-ray image sensor can reduce the X-ray harm to human sharply when it is used in the medical diagnoses. At last we analyzed and looked forward the system's application in medical engineering and the related fields.

  16. Electronic states and phonon properties of Ge{sub x}Si{sub 1−x} nanostructures

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, P.Q. [Department of Applied Physics, Nanjing Tech University, Nanjing 211816 (China); National Laboratory of Solid State Microstructures and Department of Physics, Nanjing University, Nanjing 210093 (China); Liu, L.Z. [National Laboratory of Solid State Microstructures and Department of Physics, Nanjing University, Nanjing 210093 (China); Yang, Y.M. [Department of Physics, Southern University, Nanjing 210096 (China); Wu, X.L., E-mail: hkxlwu@nju.edu.cn [National Laboratory of Solid State Microstructures and Department of Physics, Nanjing University, Nanjing 210093 (China); Department of Physics, NingBo University, NingBo 3153001 (China)

    2015-07-15

    Ge{sub x}Si{sub 1−x} nanostructures that can be manipulated through size reduction, geometry variation, and alloying, are considered as one of the key developments for next generation technologies, due to their easy processing, unique properties, and compatibility with the existent silicon-based microelectronic industry. In this review, we have thoroughly discussed the major advances in electronic structures and phonon properties of Ge{sub x}Si{sub 1−x} nanocrystals (NCs). Experimental and theoretical characterization related to several main factors, for example, size, composition, strain, temperature, and interface and surface were presented with special emphasis in low-frequency Raman scattering. Current difficulties in explaining the Raman spectra are the assignment of the low-frequency modes because of the complexity of the environment around the NCs, thus different theoretical models are introduced in detail to deal with different properties of Ge{sub x}Si{sub 1−x} alloy NCs including Lamb’s theory, complex-frequency (CF) model, core–shell matrix (CMS) model and spatial coherence effect model. - Highlights: • Major advances in electronic structures and phonon properties of Ge{sub x}Si{sub 1−x} nanocrystals are discussed thoroughly. • Experimental and theoretical characterization related to size, composition, strain, temperature, and interface/surface are elucidated. • Low-frequency Raman spectra are specially described based on spatial coherence effect model.

  17. Study on Energy Productivity Ratio (EPR) at palm kernel oil processing factory: case study on PT-X at Sumatera Utara Plantation

    Science.gov (United States)

    Haryanto, B.; Bukit, R. Br; Situmeang, E. M.; Christina, E. P.; Pandiangan, F.

    2018-02-01

    The purpose of this study was to determine the performance, productivity and feasibility of the operation of palm kernel processing plant based on Energy Productivity Ratio (EPR). EPR is expressed as the ratio of output to input energy and by-product. Palm Kernel plan is process in palm kernel to become palm kernel oil. The procedure started from collecting data needed as energy input such as: palm kernel prices, energy demand and depreciation of the factory. The energy output and its by-product comprise the whole production price such as: palm kernel oil price and the remaining products such as shells and pulp price. Calculation the equality of energy of palm kernel oil is to analyze the value of Energy Productivity Ratio (EPR) bases on processing capacity per year. The investigation has been done in Kernel Oil Processing Plant PT-X at Sumatera Utara plantation. The value of EPR was 1.54 (EPR > 1), which indicated that the processing of palm kernel into palm kernel oil is feasible to be operated based on the energy productivity.

  18. The MCNP simulation of the X-ray leakage of X-ray security inspection equipment

    International Nuclear Information System (INIS)

    Wang Kai; Liu Bin; Hu Wenchao; Zhao Wei

    2011-01-01

    Objective: To simulate the radiation leakage of the X-ray security inspection equipment used in the subways stations. Methods: We use the MCNP4C code to simulate the X-ray leakage of the equipment during the working process. Result: the biggest amount of radiation received by the body is 8.26 μSv/a, however, if the Lead screens of the X-ray security equipment is intact, the amount of radiation received by the body is only 0.0727 μSv/a. The final. Conclusions: When the baggage get in /out the X-ray security inspection equipment, the gas in Lead screens was made, and then the amount of radiation received by human body increased; The amount of radiation received by the body is close to but still below 10 μSv/a which is the exemption criteria set by the 'safety of radiation sources of ionizing radiation protection and basic standards'(GB18871-2002). (authors)

  19. Modeling X-linked ancestral origins in multiparental populations

    NARCIS (Netherlands)

    Zheng, Chaozhi

    2015-01-01

    The models for the mosaic structure of an individual's genome from multiparental populations have been developed primarily for autosomes, whereas X chromosomes receive very little attention. In this paper, we extend our previous approach to model ancestral origin processes along two X chromosomes

  20. X-UV lasers and their promising applications

    International Nuclear Information System (INIS)

    Ros, D.

    2004-01-01

    The author reviews 30 years of research and achievements concerning X-UV lasers. Typical features of X-UV lasers are: a large number of photons emitted per impulse (between 10 12 and 10 14 ) and very short impulses (between 1 and 100 ps). When a crystal is irradiated by a X-UV laser, these features favor new physical processes that did not appear when the irradiation was performed with other X-UV sources like synchrotron radiation for instance. Their high brilliance and coherence properties make them efficient means as irradiating sources or imaging tools. X-UV laser interferometry allows the mapping of a surface at the nano-metric scale without any interaction between the laser beam and the surface. (A.C.)

  1. Beyond the Black Box: Coupling x-ray tomographic imaging of multi-phase flow processes to numerical models and traditional laboratory measurements

    DEFF Research Database (Denmark)

    Wildenschild, Dorthe; Porter, M.L.; Schaap, M.G.

    Quantitative non-invasive imaging has evolved rapidly in the last decade, and is now being used to assess a variety of problems in vadose zone research, including unsaturated flow and transport of water and contaminants, macropore-dominated processes, soil-water-root interactions, more recent work...... on colloidal processes, and significant work on NAPL-water interactions . We are now able to use non-invasive imaging to probe processes that could not previously be quantified because of lack of opacity, resolution, or accurate techniques for quantitative measurement. This work presents an overview of recent...... advances in x-ray microtomography techniques that can generate high-resolution image-based data for (1) validation of pore-scale multi-phase flow models such as the lattice-Boltzmann technique and pore network models (with respect to fluid saturations, fluid distribution, and relationships among capillary...

  2. Control of gallium incorporation in sol–gel derived CuIn{sub (1−x)}Ga{sub x}S{sub 2} thin films for photovoltaic applications

    Energy Technology Data Exchange (ETDEWEB)

    Bourlier, Yoan [Institut de Recherche sur les Composants logiciels et matériels pour l’Information et la Communication Avancée (IRCICA), CNRS USR 3380, Université Lille 1, 50 avenue Halley, 59655 Villeneuve d’Ascq CEDEX (France); Cristini Robbe, Odile [Institut de Recherche sur les Composants logiciels et matériels pour l’Information et la Communication Avancée (IRCICA), CNRS USR 3380, Université Lille 1, 50 avenue Halley, 59655 Villeneuve d’Ascq CEDEX (France); Laboratoire de Physique des Lasers, Atomes et Molécules (PhLAM), CNRS UMR 8523, Université Lille, 59655 Villeneuve d’Ascq CEDEX (France); Lethien, Christophe [Institut de Recherche sur les Composants logiciels et matériels pour l’Information et la Communication Avancée (IRCICA), CNRS USR 3380, Université Lille 1, 50 avenue Halley, 59655 Villeneuve d’Ascq CEDEX (France); Laboratoire de Physique des Lasers, Atomes et Molécules (PhLAM), CNRS UMR 8523, Université Lille, 59655 Villeneuve d’Ascq CEDEX (France); Institut d’Electronique, de Microélectronique et de Nanotechnologie (IEMN), CNRS UMR 8520, Avenue Poincaré, 59652 Villeneuve d’Ascq CEDEX (France); and others

    2015-10-15

    Highlights: • CuIn{sub (1−x)}Ga{sub x}S{sub 2} thin films were prepared by sol–gel process. • Evolution of lattice parameters is characteristic of a solid solution. • Optical band gap was found to be linearly dependent on the gallium rate. - Abstract: In this paper, we report the elaboration of Cu(In,Ga)S{sub 2} chalcopyrite thin films via a sol–gel process. To reach this aim, solutions containing copper, indium and gallium complexes were prepared. These solutions were thereafter spin-coated onto the soda lime glass substrates and calcined, leading to metallic oxides thin films. Expected chalcopyrite films were finally obtained by sulfurization of oxides layers using a sulfur atmosphere at 500 °C. The rate of gallium incorporation was studied both at the solutions synthesis step and at the thin films sulfurization process. Elemental and X-ray diffraction (XRD) analyses have shown the efficiency of monoethanolamine used as a complexing agent for the preparation of CuIn{sub (1−x)}Ga{sub x}S{sub 2} thin layers. Moreover, the replacement of diethanolamine by monoethanolamine has permitted the substitution of indium by isovalent gallium from x = 0 to x = 0.4 and prevented the precipitation of copper derivatives. XRD analyses of sulfurized thin films CuIn{sub (1−x)}Ga{sub x}S{sub 2,} clearly indicated that the increasing rate of gallium induced a shift of XRD peaks, revealing an evolution of the lattice parameter in the chalcopyrite structure. These results were confirmed by Raman analyses. Moreover, the optical band gap was also found to be linearly dependent upon the gallium rate incorporated within the thin films: it varies from 1.47 eV for x = 0 to 1.63 eV for x = 0.4.

  3. Noise removal for medical X-ray images in wavelet domain

    International Nuclear Information System (INIS)

    Wang, Ling; Lu, Jianming; Li, Yeqiu; Yahagi, Takashi; Okamoto, Takahide

    2006-01-01

    Many important problems in engineering and science are well-modeled by Poisson noise, the noise of medical X-ray image is Poisson noise. In this paper, we propose a method of noise removal for degraded medical X-ray image using improved preprocessing and improved BayesShrink (IBS) method in wavelet domain. Firstly, we pre-process the medical X-ray image, Secondly, we apply the Daubechies (db) wavelet transform to medical X-ray image to acquire scaling and wavelet coefficients. Thirdly, we apply the proposed IBS method to process wavelet coefficients. Finally, we compute the inverse wavelet transform for the thresholded coefficeints. Experimental results show that the proposed method always outperforms traditional methods. (author)

  4. Selective epitaxial growth properties and strain characterization of Si1- x Ge x in SiO2 trench arrays

    Science.gov (United States)

    Koo, Sangmo; Jang, Hyunchul; Ko, Dae-Hong

    2017-04-01

    In this study, we investigated the formation of a Si1- x Ge x fin structure in SiO2 trench arrays via an ultra-high-vacuum chemical-vapor deposition (UHV-CVD) selective epitaxial growth (SEG) process. Defect generation and microstructures of Si1- x Ge x fin structures with different Ge concentrations ( x = 0.2, 0.3 and 0.45) were examined. In addition, the strain evolution of a Si1- x Ge x fin structure was analyzed by using reciprocal space mapping (RSM). An (111) facet was formed from the Si1- x Ge x epi-layer and SiO2 trench wall interface to minimize the interface and the surface energy. The Si1- x Ge x fin structures were fully relaxed along the direction perpendicular to the trenches regardless of the Ge concentration. On the other hand, the fin structures were fully or partially strained along the direction parallel to the trenches depending on the Ge concentration: fully strained Si0.8Ge0.2 and Si0.7Ge0.3, and a Si0.55Ge0.45 strain-relaxed buffer. We further confirmed that the strain on the Si1- x Ge x fin structures remained stable after oxide removal and H2/N2 post-annealing.

  5. PETA KENDALI X DENGAN UKURAN SAMPEL DAN INTERVAL PENGAMBILAN SAMPEL YANG BERVARIASI

    Directory of Open Access Journals (Sweden)

    Tanti Octavia

    2000-01-01

    Full Text Available Shewhart X chart is widely used in statistical process control for monitoring variable data and has shown good performance in detecting large mean shift but less sensitive in detecting moderate to small process shift. X chart with variable sample size and sampling interval (VSSI X chart is proposed to enhance the ability of detecting moderate to small process shift. The performance of VSSI X chart is compared with those of Shewhart X chart, VSS X chart (Variable Sample Size X chart and VSI X chart (Variable Sampling Interval X chart. Performance of these control charts is presented in the form of ATS (Average Time to Signal which is obtained from computer simulation and markov chain approach. The VSSI X chart shows better performance in detecting moderate mean shift. The simulation is then continued for VSSI X chart and VSS X chart with minimum sample size n 1=1 and n 1=2. Abstract in Bahasa Indonesia : Peta kendali X Shewhart telah umum digunakan dalam pengendalian proses statistis untuk data variabel dan terbukti berfungsi dengan baik untuk mendeteksi pergeseran rerata yang besar, namun kurang cepat dalam mendeteksi pergeseran rerata yang sedang hingga kecil. Untuk mengatasi kelemahan ini, diusulkan penggunaan peta kendali X dengan ukuran sampel dan interval pengambilan sampel yang bervariasi (peta kendali VSSI. Kinerja peta kendali X VSSI dibandingkan dengan kinerja peta kendali Shewhart, peta kendali X VSS (peta kendali X dengan ukuran sampel yang bervariasi, dan peta kendali X VSI (peta kendali X dengan interval waktu pengambilan sampel yang bervariasi. Kinerja peta kendali dinyatakan dalam nilai ATS (Average Time to Signal yang didapatkan dari hasil simulasi program komputer maupun perhitungan Rantai Markov. Peta kendali X VSSI terbukti mempunyai kinerja yang lebih baik dalam mendeteksi pergeseran rerata yang sedang. Selain itu juga disimulasikan penggunaan peta kendali X VSSI dan peta kendali X VSS dengan ukuran sampel minimum n1=1 dan n1

  6. Microstructural Evolution and the Precipitation Behavior in X90 Linepipe Steel During Isothermal Processing

    Science.gov (United States)

    Tian, Y.; Wang, H. T.; Wang, Z. D.; Misra, R. D. K.; Wang, G. D.

    2018-03-01

    Thermomechanical controlled processing of 560-MPa (X90) linepipe steel was simulated in the laboratory using a thermomechanical simulator to study the microstructural evolution and precipitation behavior during isothermal holding. The results indicated that martensite was obtained when the steels were isothermally held for 5 s at 700 °C. Subsequently, granular bainite and acicular ferrite transformation occurred with increased holding time. Different amount of polygonal ferrite formed after isothermally holding for 600-3600 s. Pearlite nucleated after isothermally holding for 3600 s. Precipitation occurred after isothermal holding for 5 s and continuous precipitation occurred at grain boundaries after isothermally holding for 600 s. After isothermally holding for 3600 s, large Nb/Ti carbide precipitated. The presence of MX-type precipitates was confirmed by diffraction pattern. The interphase precipitation (IP) occurred between 5 and 30 s. Maximum hardness was obtained after isothermally holding for 600 s when IP occurred and rapidly decreased to a low value, mainly because polygonal ferrite dominated the microstructure after isothermally holding for 3600 s.

  7. GPU-based optical propagation simulator of a laser-processed crystal block for the X'tal cube PET detector.

    Science.gov (United States)

    Ogata, Yuma; Ohnishi, Takashi; Moriya, Takahiro; Inadama, Naoko; Nishikido, Fumihiko; Yoshida, Eiji; Murayama, Hideo; Yamaya, Taiga; Haneishi, Hideaki

    2014-01-01

    The X'tal cube is a next-generation DOI detector for PET that we are developing to offer higher resolution and higher sensitivity than is available with present detectors. It is constructed from a cubic monolithic scintillation crystal and silicon photomultipliers which are coupled on various positions of the six surfaces of the cube. A laser-processing technique is applied to produce 3D optical boundaries composed of micro-cracks inside the monolithic scintillator crystal. The current configuration is based on an empirical trial of a laser-processed boundary. There is room to improve the spatial resolution by optimizing the setting of the laser-processed boundary. In fact, the laser-processing technique has high freedom in setting the parameters of the boundary such as size, pitch, and angle. Computer simulation can effectively optimize such parameters. In this study, to design optical characteristics properly for the laser-processed crystal, we developed a Monte Carlo simulator which can model arbitrary arrangements of laser-processed optical boundaries (LPBs). The optical characteristics of the LPBs were measured by use of a setup with a laser and a photo-diode, and then modeled in the simulator. The accuracy of the simulator was confirmed by comparison of position histograms obtained from the simulation and from experiments with a prototype detector composed of a cubic LYSO monolithic crystal with 6 × 6 × 6 segments and multi-pixel photon counters. Furthermore, the simulator was accelerated by parallel computing with general-purpose computing on a graphics processing unit. The calculation speed was about 400 times faster than that with a CPU.

  8. Absorption of longitudinal high-frequency acoustic waves in Ysub(3-x)Lusub(x)Alsub(5)Osub(12) crystals

    International Nuclear Information System (INIS)

    Gulyaev, Yu.V.; Ivanov, S.N.; Kozorezov, A.G.; Kotelyanskij, I.M.; Medved', V.V.; Akhmetov, S.F.; Davydchenko, A.G.

    1983-01-01

    Absorption of longitudinal high frequency acoustic waves in Ysub(3-x)Lusub(x)Alsub(5)Osub(12) l0<=x<=3) crystals is investigated theoretically and experimentally at temperatures T<80 K in the case when the absorption in a pure crystal is due to three-phonon processes. It is shown that the absorption of acoustic waves depends pronouncedly on the impurity concentration. The frequency dependence of sound absorption at low temperatures is found to possess a number of peculiarities. The form of the dependence qualitatively corresponds to that predicted theoretically

  9. Nanopowders Y{sub 1−y}Nd{sub y}V{sub 1−x}Cr{sub x}O{sub 4} with y=0 and 1; x=0, 0.1, 0.2 and 0.5 synthesized by a sol–gel process. Relationship between morphological characteristics and optical properties

    Energy Technology Data Exchange (ETDEWEB)

    Alcaraz, L. [Departamento de Química Inorgánica I, Facultad de Ciencias Químicas, Universidad Complutense de Madrid, Ciudad Universitaria s/n, 28040 Madrid (Spain); Isasi, J., E-mail: isasi@quim.ucm.es [Departamento de Química Inorgánica I, Facultad de Ciencias Químicas, Universidad Complutense de Madrid, Ciudad Universitaria s/n, 28040 Madrid (Spain); Caballero, A.C. [Departamento de Electrocerámica, Instituto de Cerámica y Vidrio (CSIC), Kelsen, 5, 28049 Madrid (Spain); Izquierdo, J.G.; Bañares, L. [Departamento de Química Física I and Centro de Láseres Ultrarrápidos, Facultad de Ciencias Químicas, Universidad Complutense de Madrid, Ciudad Universitaria s/n, 28040 Madrid (Spain)

    2015-05-15

    Y{sub 1−y}Nd{sub y}V{sub 1−x}Cr{sub x}O{sub 4} nanopowders with y=0 and 0.1; x=0, 0.1, 0.2 and 0.5, have been synthetized by a sol–gel process followed by heating in an oxygen flow. This second treatment was done only in the case of samples containing chromium. The samples have been characterized by X-ray diffraction (XRD), Fourier Transform Infrared (FTIR) spectroscopy, scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The structural analysis revealed that when chromium was inserted at vanadium-sites in Y{sub 0.9}Nd{sub 0.1}VO{sub 4}, the host retained the tetragonal symmetry corresponding to a zircon-type structure, attributed to the space group I4{sub 1}/amd. In addition, a loss of crystallinity was observed when chromium substitutes vanadium into the Y{sub 0.9}Nd{sub 0.1}VO{sub 4} host. The morphological studies revealed agglomerates of spherical particles whose size is increased with the Cr content and confirmed the composition of all synthetized samples. FTIR spectra of these samples exhibit a broadening and a slight shift of the bands around 830 cm{sup −1} towards higher values of frequency when the chromium content increases. The effect of vanadium substitution by chromium on the optical properties was also evaluated by UV–vis absorption and photoluminescence (PL) spectroscopies. The broad UV band absorption is due to the presence of Cr{sup 5+}. A decrease of PL emission is found when chromium substitutes vanadium in the YVO{sub 4} host. - Highlights: • Nanophosphors Y{sub 1−y}Nd{sub y}V{sub 1−x}Cr{sub x}O{sub 4} with y=0, 0.1 and x=0, 0.1, 0.2 and 0.5 have been synthesized. • Structural analysis reveals structural distortions associated to chromium insertion. • Morphological studies confirm the nanocristalline size and the stoichiometry of synthesized samples. • Chromium insertion causes a decrease of the PL emission intensity.

  10. BlenX-based compositional modeling of complex reaction mechanisms

    Directory of Open Access Journals (Sweden)

    Judit Zámborszky

    2010-02-01

    Full Text Available Molecular interactions are wired in a fascinating way resulting in complex behavior of biological systems. Theoretical modeling provides a useful framework for understanding the dynamics and the function of such networks. The complexity of the biological networks calls for conceptual tools that manage the combinatorial explosion of the set of possible interactions. A suitable conceptual tool to attack complexity is compositionality, already successfully used in the process algebra field to model computer systems. We rely on the BlenX programming language, originated by the beta-binders process calculus, to specify and simulate high-level descriptions of biological circuits. The Gillespie's stochastic framework of BlenX requires the decomposition of phenomenological functions into basic elementary reactions. Systematic unpacking of complex reaction mechanisms into BlenX templates is shown in this study. The estimation/derivation of missing parameters and the challenges emerging from compositional model building in stochastic process algebras are discussed. A biological example on circadian clock is presented as a case study of BlenX compositionality.

  11. Multi-block methods in multivariate process control

    DEFF Research Database (Denmark)

    Kohonen, J.; Reinikainen, S.P.; Aaljoki, K.

    2008-01-01

    methods the effect of a sub-process can be seen and an example with two blocks, near infra-red, NIR, and process data, is shown. The results show improvements in modelling task, when a MB-based approach is used. This way of working with data gives more information on the process than if all data...... are in one X-matrix. The procedure is demonstrated by an industrial continuous process, where knowledge about the sub-processes is available and X-matrix can be divided into blocks between process variables and NIR spectra.......In chemometric studies all predictor variables are usually collected in one data matrix X. This matrix is then analyzed by PLS regression or other methods. When data from several different sub-processes are collected in one matrix, there is a possibility that the effects of some sub-processes may...

  12. Økologisk risikovurdering af gen-modificeret majs-krydsning: 1507 x 59122 x MON810 x NK603 i anmeldelse vedr. markedsføring under Forordning 1829/2003/EF

    DEFF Research Database (Denmark)

    Kjellsson, Gøsta; Sørensen, Jesper Givskov; Damgaard, Christian

    2012-01-01

    DCE’s konklusioner vedr. den økologiske risikovurdering af den genmodificerede 1507x59122xMON810xNK603-majs i Danmark Den genmodificerede fire-stakkede majskrydsning adskiller sig fra konven-tionelle majs ved at have indsat gener der gør planterne tolerante over for herbiciderne glufosinat-ammonium...... for import and processing only, will have little or no adverse environmental consequences. In case of accidental mixing and/or dispersal of GMO-seed leading to cultivation of the GMO, DCE suggests that case-specific environ-mental monitoring is needed for detection of possible adverse effects on insect...

  13. The X-ray imager on AXO

    DEFF Research Database (Denmark)

    Budtz-Jørgensen, Carl; Kuvvetli, Irfan; Westergaard, Niels Jørgen Stenfeldt

    2001-01-01

    DSRI has initiated a development program of CZT X-ray and gamma-ray detectors employing strip readout techniques. A dramatic improvement of the energy response was found operating the detectors as the so-called drift detectors. For the electronic readout, modern ASIC chips were investigated....... Modular design and the low-power electronics will make large area detectors using the drift strip method feasible. The performance of a prototype CZT system will be presented and discussed. One such detector system has been proposed for future space missions: the X-Ray Imager (XRI) on the Atmospheric X-ray...... Observatory (AXO), which is a mission proposed to the Danish Small Satellite Program and is dedicated to observations of X-ray generating processes in the Earth's atmosphere. Of special interest will be simultaneous optical and X-ray observations of sprites that are flashes appearing directly above an active...

  14. X-ray microcalorimeter arrays fabricated by surface micromachining

    International Nuclear Information System (INIS)

    Hilton, G.C.; Beall, J.A.; Deiker, S.; Vale, L.R.; Doriese, W.B.; Beyer, Joern; Ullom, J.N.; Reintsema, C.D.; Xu, Y.; Irwin, K.D.

    2004-01-01

    We are developing arrays of Mo/Cu transition edge sensor-based detectors for use as X-ray microcalorimeters and sub-millimeter bolometers. We have fabricated 8x8 pixel X-ray microcalorimeter arrays using surface micromachining. Surface-micromachining techniques hold the promise of scalability to much larger arrays and may allow for the integration of in-plane multiplexer elements. In this paper we describe the surface micromachining process and recent improvements in the device geometry that provide for increased mechanical strength. We also present X-ray and heat pulse spectra collected using these detectors

  15. Hard X-ray studies on the Castor tokamak

    International Nuclear Information System (INIS)

    Mlynar, J.

    1990-04-01

    The electron runaway processes in tokamaks are discussed with regard to hard X radiation measurements. The origin and confinement of runaway electrons, their bremsstrahlung spectra and the influence of lower hybrid current drive on the distribution of high-energy electrons are analyzed for the case of the Castor tokamak. The hard X-ray spectrometer designed for the Castor tokamak is also described and preliminary qualitative results of hard X-ray measurements are presented. The first series of integral measurements made it possible to map the azimuthal dependence of the hard X radiation

  16. Study on the management of the Boohung X-Dol 90 developer and fixing solution for automatic X-ray film processor

    International Nuclear Information System (INIS)

    Hyan, Yong Sil; Kim, Heung Tae; Kwon, Dal Gwan; Choi, Myung Joon; Cheung, Hwan

    1986-01-01

    Recently, Demands of Automatic X-ray film Processors are increasing more and more at University Hospitals and general Hospitals and Private clinics, but various troubles because of incorrect control were found out. Authors have researched to find out the function and Activity of Automatic X-ray film processor for 2 weeks Kodak RPX-OMAT Processor and Sakura GX3000 Processor and Doosan parka 2000 Processor and results obtained were as follows: 1. Automatic X-ray film processor have an advantage to conduct the rapid treatment of X-ray film processing but incorrect handling of developing and fixing agents were brought about a great change in Contrast and Optical density of X-ray film pictures. 2. About 300 X-ray film could be finished by same developing and fixing solution without exchanging any other solutions in each Automatic X-ray film processor

  17. Single-source-precursor synthesis of dense SiC/HfC(x)N(1-x)-based ultrahigh-temperature ceramic nanocomposites.

    Science.gov (United States)

    Wen, Qingbo; Xu, Yeping; Xu, Binbin; Fasel, Claudia; Guillon, Olivier; Buntkowsky, Gerd; Yu, Zhaoju; Riedel, Ralf; Ionescu, Emanuel

    2014-11-21

    A novel single-source precursor was synthesized by the reaction of an allyl hydrido polycarbosilane (SMP10) and tetrakis(dimethylamido)hafnium(iv) (TDMAH) for the purpose of preparing dense monolithic SiC/HfC(x)N(1-x)-based ultrahigh temperature ceramic nanocomposites. The materials obtained at different stages of the synthesis process were characterized via Fourier transform infrared (FT-IR) as well as nuclear magnetic resonance (NMR) spectroscopy. The polymer-to-ceramic transformation was investigated by means of MAS NMR and FT-IR spectroscopy as well as thermogravimetric analysis (TGA) coupled with in situ mass spectrometry. Moreover, the microstructural evolution of the synthesized SiHfCN-based ceramics annealed at different temperatures ranging from 1300 °C to 1800 °C was characterized by elemental analysis, X-ray diffraction, Raman spectroscopy and transmission electron microscopy (TEM). Based on its high temperature behavior, the amorphous SiHfCN-based ceramic powder was used to prepare monolithic SiC/HfC(x)N(1-x)-based nanocomposites using the spark plasma sintering (SPS) technique. The results showed that dense monolithic SiC/HfC(x)N(1-x)-based nanocomposites with low open porosity (0.74 vol%) can be prepared successfully from single-source precursors. The average grain size of both HfC0.83N0.17 and SiC phases was found to be less than 100 nm after SPS processing owing to a unique microstructure: HfC0.83N0.17 grains were embedded homogeneously in a β-SiC matrix and encapsulated by in situ formed carbon layers which acted as a diffusion barrier to suppress grain growth. The segregated Hf-carbonitride grains significantly influenced the electrical conductivity of the SPS processed monolithic samples. While Hf-free polymer-derived SiC showed an electrical conductivity of ca. 1.8 S cm(-1), the electrical conductivity of the Hf-containing material was analyzed to be ca. 136.2 S cm(-1).

  18. Thermoanalytical investigation of the hydrogen absorption behaviour of Sm{sub 2}Fe{sub 17-x}Ga{sub x} at high hydrogen pressures

    Energy Technology Data Exchange (ETDEWEB)

    Handstein, A.; Kubis, M.; Gebel, B.; Mueller, K.-H.; Schultz, L. [Institut fuer Festkoerper- und Werkstofforschung Dresden e.V. (Germany). Inst. fuer Metallische Werkstoffe; Gutfleisch, O.; Harris, I.R. [Institut fuer Festkoerper- und Werkstofforschung Dresden e.V. (Germany). Inst. fuer Metallische Werkstoffe]|[Birmingham Univ. (United Kingdom). School of Metallurgy and Materials

    1998-07-01

    The complete disproportionation of Sm{sub 2}Fe{sub 17-x}Ga{sub x} during annealing in hydrogen is hindered due to an increased stability of the compounds with a higher Ga content (x {>=} 1). Therefore the HD process as the first step of HDDR (hydrogenation-disproportionation-desorption-recombination) has to be carried out at a high hydrogen pressure for x {>=} 1. The hydrogen absorption behaviour of Sm{sub 2}Fe{sub 17-x}Ga{sub x} (x = 0, 0.5, 1 and 2) was investigated by means of hydrogen differential thermal analysis (HDTA) and high pressure differential scanning calorimetry (HPDSC) at hydrogen pressures up to 70 bar. A dependency of hydrogenation and disproportionation temperatures on hydrogen pressure and Ga content was found. The comparison with other substituents (M = Al and Si) instead of M = Ga showed an increased stability of Sm{sub 2}Fe{sub 17-x}M{sub x} compounds against disproportionation by hydrogen in the sequence Al, Ga and Si. The Curie temperatures of the interstitially hydrogenated Th{sub 2}Zn{sub 17}-type materials increase with the hydrogen pressure. In order to produce coercive and thermally stable Sm{sub 2}Fe{sub 15}Ga{sub 2}C{sub y} powder by means of the HDDR process, we recombined material disproportionated at different hydrogen pressures. Preliminary results of magnetic properties of this HDDR treated and gas-carburized Sm{sub 2}Fe{sub 15}Ga{sub 2}C{sub y} are discussed. (orig.)

  19. The HyMeX database

    Science.gov (United States)

    Brissebrat, Guillaume; Belmahfoud, Nizar; Boichard, Jean-Luc; Cloché, Sophie; Delacour, Thomas; Ferré, Hélène; Fleury, Laurence; Labatut, Laurent; Ramage, Karim; André, François

    2015-04-01

    The HYdrological cycle in the Mediterranean Experiment (HyMeX) international project aims at a better understanding and quantification of the hydrological cycle and related processes in the Mediterranean, with emphasis on high-impact weather events, inter-annual to decadal variability of the Mediterranean coupled system, and associated trends in the context of global change. The project includes long term monitoring of environmental parameters between 2010 and 2020, intensive field campaigns, use of satellite data, modelling studies, as well as post event field surveys and value-added products processing. The project gathers together a rich collection of datasets that can be used for any data calibration or cross-validation study. The HyMeX data management system has been designed and developed in the context of the Mediterranean Integrated STudies at Regional And Local Scales program (MISTRALS) data portal. The MISTRALS data portal is a distributed system, that enables users to access datasets produced by every project (HyMeX, ChArMEx, MerMEx...) and managed by different data centres. The HyMeX database relies on a strong collaboration between OMP and IPSL data centers. Local observation data (ground-based stations, mobile platforms, questionnaires...) are managed by OMP team while gridded data (satellite products, model outputs, radar data...) are managed by IPSL team. The HyMeX database contains a wide variety of datasets: - 250 hydrological, meteorological, ocean and soil in situ datasets. - 45 radar datasets. - 25 satellite products. - 95 atmosphere, ocean and land surface model outputs from operational (re-)analysis or forecasts and from research simulations. - 5 post event survey datasets. All the datasets are documented in compliance with metadata international standards. Many in situ data have been inserted in a relational database, in order to enable more accurate data selection and download of different datasets in a shared format. Radar datasets and

  20. Residual stress characterization of welds using x-ray diffraction techniques

    International Nuclear Information System (INIS)

    Pineault, J.A.; Brauss, M.E.

    1996-01-01

    Neglect of residual stresses created during processes lead to stress corrosion cracking, distortion, fatigue cracking, premature failures in components, and instances of over design. Automated residual stress mapping and truly portable equipment have now made the characterization of residual stresses using x-ray diffraction (XRI) practical. The nondestructive nature of the x-ray diffraction technique has made the tile residual stress characterization of welds a useful tool for process optimization and failure analysis, particularly since components can be measured before and after welding and post welding processes. This paper illustrates the importance of residual stress characterization in welds and presents examples where x-ray diffraction techniques were applied in the characterization of various kinds of welds. arc welds, TIG welds, resistance welds, laser welds and electron beam welds. Numerous techniques are available to help manage potentially harmfull residual stresses created during the welding process thus, the effects of a few example post weld processes such as grinding, heat treating and shot peening are also addressed